Sample records for vacuum-assisted core biopsy

  1. The cost effectiveness of vacuum-assisted versus core-needle versus surgical biopsy of breast lesions.

    PubMed

    Fernández-García, P; Marco-Doménech, S F; Lizán-Tudela, L; Ibáñez-Gual, M V; Navarro-Ballester, A; Casanovas-Feliu, E

    To determine the cost effectiveness of breast biopsy by 9G vacuum-assisted guided by vertical stereotaxy or ultrasonography in comparison with breast biopsy by 14G core-needle biopsy and surgical biopsy. We analyzed a total of 997 biopsies (181 vacuum-assisted, 626 core, and 190 surgical biopsies). We calculated the total costs (indirect and direct) of the three types of biopsy. We did not calculate intangible costs. We measured the percentage of correct diagnoses obtained with each technique. To identify the most cost-effective option, we calculated the mean ratios for the three types of biopsies. Total costs were €225.09 for core biopsy, €638.90 for vacuum-assisted biopsy, and €1780.01 for surgical biopsy. The overall percentage of correct diagnoses was 91.81% for core biopsy, 94.03% for vacuum-assisted biopsy, and 100% for surgical biopsy; however, these differences did not reach statistical significance (p=0.3485). For microcalcifications, the percentage of correct diagnoses was 50% for core biopsy and 96.77% for vacuum-assisted biopsy (p<0.0001). For nodules, there were no significant differences among techniques. The mean cost-effectiveness ratio considering all lesions was 2.45 for core biopsy, 6.79 for vacuum-assisted biopsy, and 17.80 for surgical biopsy. Core biopsy was the dominant option for the diagnosis of suspicious breast lesions in general. However, in cases with microcalcifications, the low percentage of correct diagnoses achieved by core biopsy (50%) advises against its use in this context, where vacuum-assisted biopsy would be the technique of choice because it is more cost-effective than surgical biopsy, the other technique indicated for biopsying microcalcifications. Copyright © 2016 SERAM. Publicado por Elsevier España, S.L.U. All rights reserved.

  2. Ultrasound-Guided Core-Needle Versus Vacuum-Assisted Breast Biopsy: A Cost Analysis Based on the American Society of Breast Surgeons' Mastery of Breast Surgery Registry.

    PubMed

    Grady, Ian; Vasquez, Tony; Tawfik, Sara; Grady, Sean

    2017-03-01

    To evaluate the cost-efficacy of vacuum-assisted ultrasound-guided breast biopsy instruments compared to ultrasound-guided 14-gauge spring-loaded core-needle biopsy. The American Society of Breast Surgeons' Mastery of Breast Surgery Registry was reviewed. Biopsy findings, any rebiopsy, and the instrument used were abstracted for 31,451 ultrasound-guided biopsy procedures performed between 2001 and July 2014. Rates of cancer diagnosis and rebiopsy were calculated for each instrument. A linear mathematical model was developed to calculate total cost per cancer diagnosis, including procedural costs and the costs of any additional surgical rebiopsy procedures. Mean cost per cancer diagnosis with confidence limits was then determined for 14-gauge spring-loaded core-needle biopsy and 14 different vacuum-assisted instruments. For 14-gauge spring-loaded core-needle biopsy, mean cost per cancer diagnosis was $4346 (4327-$4366). For the vacuum-assisted instruments, mean cost per cancer diagnosis ranged from a low of $3742 ($3732-$3752) to a high of $4779 ($4750-$4809). Vacuum-assisted instruments overall were more cost-effective than core with a mean cost per cancer diagnosis of $4052 ($4038-$4067) (p < 0.05). Tethered vacuum-assisted instruments performed best with a mean cost per cancer diagnosis of $3978 ($3964-$3991) (p < 0.05). Nontethered devices had a mean cost per cancer diagnosis of $4369 ($4350-$4388), a result no better than core (p < 0.05). Ultrasound-guided vacuum-assisted breast biopsy had a lower mean cost per cancer diagnosis than 14-gauge spring-loaded core-needle biopsy. This advantage was only seen in tethered vacuum-assisted instruments. Within device families, larger instruments tended to outperform smaller instruments.

  3. Post-Vacuum-Assisted Stereotactic Core Biopsy Clip Displacement: A Comparison Between Commercially Available Clips and Surgical Clip.

    PubMed

    Yen, Peggy; Dumas, Sandra; Albert, Arianne; Gordon, Paula

    2018-02-01

    The placement of localization clips following percutaneous biopsy is a standard practice for a variety of situations. Subsequent clip displacement creates challenges for imaging surveillance and surgical planning, and may cause confusion amongst radiologists and between surgeons and radiologists. Many causes have been attributed for this phenomenon including the commonly accepted "accordion effect." Herein, we investigate the performance of a low cost surgical clip system against 4 commercially available clips. We retrospectively reviewed 2112 patients who underwent stereotactic vacuum-assisted core biopsy followed by clip placement between January 2013 and June 2016. The primary performance parameter compared was displacement >10 mm following vacuum-assisted stereotactic core biopsy. Within the group of clips that had displaced, the magnitude of displacement was compared. There was a significant difference in displacement among the clip types (P < .0001) with significant pairwise comparisons between pediatric surgical clips and SecureMark (38% vs 28%; P = .001) and SenoMark (38% vs 27%; P = .0001) in the proportion displaced. The surgical clips showed a significant magnitude of displacement of approximately 25% greater average distance displaced. As a whole, the commercial clips performed better than the surgical clip after stereotactic vacuum-assisted core biopsy suggesting the surrounding outer component acts to anchor the central clip and minimizes clip displacement. The same should apply to tomosynthesis-guided biopsy. Crown Copyright © 2017. Published by Elsevier Inc. All rights reserved.

  4. Emergent Embolization of Arterial Bleeding after Vacuum-Assisted Breast Biopsy

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Fischman, Aaron M., E-mail: aaron.fischman@mountsinai.org; Epelboym, Yan, E-mail: yan.epelboym@mssm.edu; Siegelbaum, Robert H., E-mail: rhsiegelbaum@gmail.com

    2012-02-15

    Vacuum-assisted core breast biopsy has become important in evaluating patients with suspicious breast lesions. It has proven to be a relatively safe procedure that in rare cases can result in vascular complications. These are the first reported cases of transcatheter embolization of uncontrolled breast hemorrhage after vacuum-assisted breast biopsy. With increased use of biopsy and larger-gauge devices, breast imaging groups may consider embolotherapy as a safe alternative for treatment of hemorrhage in a select group of patients.

  5. Fast MRI-guided vacuum-assisted breast biopsy: initial experience.

    PubMed

    Liberman, Laura; Morris, Elizabeth A; Dershaw, D David; Thornton, Cynthia M; Van Zee, Kimberly J; Tan, Lee K

    2003-11-01

    The purpose of this study was to evaluate a new method for performing MRI-guided vacuum-assisted breast biopsy in a study of lesions that had subsequent surgical excision. SUBJECTS AND METHODS. Twenty women scheduled for MRI-guided needle localization and surgical biopsy were prospectively entered in the study. MRI-guided biopsy was performed with a vacuum-assisted probe, followed by placement of a localizing clip, and then needle localization for surgical excision. Vacuum-assisted biopsy and surgical histology were correlated. Vacuum-assisted biopsy was successfully performed in 19 (95%) of the 20 women. The median size of 27 MRI-detected lesions that had biopsy was 1.0 cm (range, 0.4-6.4 cm). Cancer was present in eight (30%) of 27 lesions and in six (32%) of 19 women; among these eight cancers, five were infiltrating and three were ductal carcinoma in situ (DCIS). Among these 27 lesions, histology was benign at vacuum-assisted biopsy and at surgery in 19 (70%), cancer at vacuum-assisted biopsy in six (22%), atypical ductal hyperplasia at vacuum-assisted biopsy and DCIS at surgery in one (4%), and benign at vacuum-assisted biopsy with surgery showing microscopic DCIS that was occult at MRI in one (4%). The median time to perform vacuum-assisted biopsy of a single lesion was 35 min (mean, 35 min; range, 24-48 min). Placement of a localizing clip, attempted in 26 lesions, was successful in 25 (96%) of 26, and the clip was retrieved on specimen radiography in 22 (96%) of 23. One complication occurred: a hematoma that resolved with compression. MRI-guided vacuum-assisted biopsy is a fast, safe, and accurate alternative to surgical biopsy for breast lesions detected on MRI.

  6. Flat epithelial atypia in directional vacuum-assisted biopsy of breast microcalcifications: surgical excision may not be necessary.

    PubMed

    McCroskey, Zulfia; Sneige, Nour; Herman, Carolyn R; Miller, Ross A; Venta, Luz A; Ro, Jae Y; Schwartz, Mary R; Ayala, Alberto G

    2018-02-21

    The aim of this study was to analyze the clinicopathological features of patients with flat epithelial atypia, diagnosed in directional vacuum-assisted biopsy targeting microcalcifications, to identify upgrade rate to in situ ductal or invasive breast carcinoma, and determine factors predicting carcinoma in the subsequent excision. We retrospectively evaluated the histological, clinical, and mammographic features of 69 cases from 65 women, with directional vacuum-assisted biopsy-diagnosed flat epithelial atypia with or without atypical ductal hyperplasia or atypical lobular hyperplasia, which underwent subsequent surgical excision. The extent and percentage of microcalcifications sampled by directional vacuum-assisted biopsy were evaluated by mammography. All biopsy and surgical excision slides were reviewed. The age of the women ranged from 40 to 85 years (mean 57 years). All patients presented with mammographically detected microcalcifications only, except in one case that had associated architectural distortion. Extent of calcifications ranged from <1 cm (n = 47), 1-3 cm (n = 15) to > 3 cm (n = 6), and no measurement (n = 1). A mean of 11 cores (range 6-25) was obtained from each lesion. Post-biopsy mammogram revealed >90% removal of calcifications in 81% of cases. Pure flat epithelial atypia represented nearly two-thirds of directional vacuum-assisted biopsy specimens (n = 43, 62%), while flat epithelial atypia coexisted with atypical ductal hyperplasia (18 cases, 26%), or atypical lobular hyperplasia (8 cases, 12%). Upon excision, none of the cases were upgraded to in situ ductal or invasive breast cancer. In one case, however, an incidental, tubular carcinoma (4 mm) was found away from biopsy site. Excluding this case, the upgrade rate was 0%. Our study adds to the growing evidence that diagnosis of flat epithelial atypia on directional vacuum-assisted biopsy for microcalcifications as the only imaging finding is not associated

  7. Papilloma diagnosed at MRI-guided vacuum-assisted breast biopsy: is surgical excision still warranted?

    PubMed

    Brennan, Sandra B; Corben, Adriana; Liberman, Laura; Dershaw, D David; Brogi, Edi; Van Zee, Kimberly J; Morris, Elizabeth

    2012-10-01

    The objective of our study was to determine the frequency of cancer at surgery in breast lesions yielding papilloma at MRI-guided 9-gauge vacuum-assisted biopsy (VAB) and to determine whether any features are associated with cancer upgrade. For this study, 1487 MRI-guided vacuum-assisted biopsies performed from January 2004 to March 2011 were reviewed. Lesions yielding papilloma were identified and classified as papilloma with or without atypia. Surgical findings were reviewed to determine the cancer rate. Statistical analysis was performed and 95% CIs were calculated. Papilloma was identified in 75 of the 1487 MRI-guided vacuum-assisted biopsies (5%). These 75 papillomas occurred in 73 women with a median age of 49 years (age range, 27-70 years). Of the 75 papillomas, 25 (33%) had atypia and 50 (67%) did not on core needle biopsy. Subsequent surgery of 67 of the 75 papillomas (89%) yielded ductal carcinoma in situ (DCIS) in four (6%; 95% CI, 2-15%). Surgery yielded DCIS in two of 23 papillomas with atypia (9%; 95% CI, 1-28%) at MRI-guided VAB and in two of 44 papillomas without atypia (5%; 95% CI, 0.4-16%) at MRI-guided VAB; these cancer rates did not differ significantly (p=0.6). Postmenopausal status (p=0.04) and histologic size of less than 0.2 cm (p=0.04) had a significant association with the cancer upgrade rate. Papilloma with or without atypia was found in 5% of patients who underwent MRI-guided VAB during the study period. Surgery revealed cancer in 6%. DCIS was found at surgery in 9% of lesions yielding papilloma with atypia versus 5% of lesions yielding papilloma without atypia. For lesions yielding papilloma with or without atypia at MRI-guided VAB, surgical excision is warranted.

  8. Histology after lumpectomy in women with epithelial atypia on stereotactic vacuum-assisted breast biopsy.

    PubMed

    Graesslin, O; Antoine, M; Chopier, J; Seror, J Y; Flahault, A; Callard, P; Daraï, E; Uzan, S

    2010-02-01

    Large-core needle biopsy of the breast (LCNB) and vacuum-assisted breast biopsy (VABB) are widely used as alternatives to open surgical biopsy (OSB) for initial diagnosis of mammographic abnormalities. Between 18% and 80% of cases in which such specimens show atypical lobular hyperplasia (ALH) or atypical ductal hyperplasia (ADH) are found to be malignant at surgery. From 1999 to 2005, 68 women with mammographic abnormalities were sampled by stereotactic VABB and presented atypical epithelial hyperplasia. Immunohistochemical staining with anti-cytokeratin 5/6 and anti-E-cadherin antibodies was performed. All women underwent a lumpectomy. Clinical, radiological or histological factors predictive of the risk of finding malignancy at surgery were sought. VABB initially showed 28 cases of ADH, 32 cases of ALH, one case of flat epithelial atypia, five cases of mixed atypia, and two cases of Lobular Carcinoma In Situ (LCIS). After slide review with immunohistochemical staining, two cases of ADH were reclassified as simple hyperplasia and two cases of ALH were reclassified as mixed atypia. Seven lesions (10.3%) that appeared to be benign on VABB were found to be malignant on OSB (Ductal Carcinoma In Situ (DCIS) in six cases and invasive ductal carcinoma in one case). ADH was the only predictive factor of malignancy on OSB (p=0.04 versus ALH). ADH diagnosed by vacuum-assisted breast biopsy frequently corresponds to cancer on open surgical biopsy. Surgical excision of all breast lesions containing atypical hyperplasia on percutaneous biopsy can be recommended. Copyright (c) 2009 Elsevier Ltd. All rights reserved.

  9. A comparison of diagnostic performance of vacuum-assisted biopsy and core needle biopsy for breast microcalcification: a systematic review and meta-analysis.

    PubMed

    Huang, Xu Chen; Hu, Xu Hua; Wang, Xiao Ran; Zhou, Chao Xi; Wang, Fei Fei; Yang, Shan; Wang, Gui Ying

    2018-03-16

    Core needle biopsy (CNB) and vacuum-assisted biopsy (VAB) are both popularly used breast percutaneous biopsies. Both of them have become reliable alternatives to open surgical biopsy (OSB) for breast microcalcification (BM). It is controversial that which biopsy method is more accurate and safer for BM. Hence, we conducted this meta-analysis to compare the diagnostic performance between CNB and VAB for BM, aiming to find out the better method. Articles according with including and excluding criteria were collected from the databases, PubMed, Embase, and the Cochrane Library. Preset outcomes were abstracted and pooled to find out the potential advantages in CNB or VAB. Seven studies were identified and entered final meta-analysis from initially found 138 studies. The rate of ductal carcinoma in situ (DCIS) underestimation was significantly lower in VAB than CNB group [risk ratio (RR) = 1.83, 95% confidence interval (CI) 1.40 to 2.40, p < 0.001]. The microcalcification retrieval rate was significantly higher in VAB than CNB group (RR = 0.89, 95% CI 0.81 to 0.98, p = 0.02), while CNB owned a significantly lower complication rate than VAB (RR = 0.18, 95% CI 0.03 to 0.93, p = 0.04). The atypical ductal hyperplasia (ADH) underestimation rates were not compared for the limited number of studies reporting this outcome. Compared with CNB, VAB shows better diagnostic performance in DCIS underestimation rate and microcalcification retrieval rate. However, CNB shows a significantly lower complication rate. More studies are needed to verify these findings.

  10. Efficacy and cost-effectiveness of stereotactic vacuum-assisted core biopsy of nonpalpable breast lesions: analysis of 602 biopsies performed over 5 years.

    PubMed

    Luparia, A; Durando, M; Campanino, P; Regini, E; Lucarelli, D; Talenti, A; Mattone, G; Mariscotti, G; Sapino, A; Gandini, G

    2011-04-01

    The authors sought to evaluate the diagnostic accuracy and cost-effectiveness of vacuum-assisted core biopsy (VACB) in comparison with diagnostic surgical excision for characterisation of nonpalpable breast lesions classified as Breast Imaging Reporting and Data System (BI-RADS) categories R3 and R4. From January 2004 to December 2008, we conducted 602 stereotactic, 11-gauge, VACB procedures on 243 nonpalpable breast lesions categorised as BI-RADS R3, 346 categorised as BI-RADS R4 and 13 categorised as BI-RADS R5. We calculated the diagnostic accuracy and cost savings of VACB by subtracting the cost of the stereotactic biopsy from that of the diagnostic surgical procedure. A total of 56% of the lesions were benign and required no further assessment. Lesions of uncertain malignant potential (B3) (23.6%) were debated at multidisciplinary meetings, and diagnostic surgical biopsy was recommended for 83.1% of them. All malignant lesions (B4 and B5) underwent surgical excision. VACB had a sensitivity of 94.9%, specificity of 98.3% and diagnostic accuracy of 97.7%. The cost savings per VACB procedure were 464.00 euro; by obviating 335 surgical biopsies, the overall cost savings was 155,440.00 euro over 5 years. VACB proved to have high diagnostic accuracy for characterising abnormalities at low to intermediate risk of malignancy and obviated surgical excision in about half of the cases, allowing for considerable cost savings.

  11. Does isolated flat epithelial atypia on vacuum-assisted breast core biopsy require surgical excision?

    PubMed

    Dialani, Vandana; Venkataraman, Shambhavi; Frieling, Gretchen; Schnitt, Stuart J; Mehta, Tejas S

    2014-01-01

    To determine whether flat epithelial atypia (FEA) found in isolation on large core vacuum-assisted biopsy (CNB) requires surgical excision. After Institutional Review Board approval, pathology reports of all patients who underwent CNB from January 1, 2005 to December 31, 2010 were reviewed. All patients with reports of isolated FEA without other atypia or in situ or invasive carcinoma were identified. Patient age, history, target on imaging, biopsy modality, and residual target post CNB noted. Histology of CNB's (blinded to surgical outcome) and subsequent surgical excisions were reviewed by a dedicated breast pathologist. Only cases with confirmed isolated FEA on review were used for data analysis. Of 2,556 CNB's performed over 6 years, 37 (1.4%) had isolated FEA confirmed on review, comprising our study population. Thirty (81%) had biopsy for calcifications on mammography and 7 (19%) for mass or non-mass like enhancement on magnetic resonance imaging. There were no US guided CNBs that met our inclusion criteria. 29 (78.4%) underwent surgical excision, 6 (16.2%) had imaging follow-up, and 2 (5.4%) were lost to follow-up. Of the 29 with surgery, 2 (6.9%) had "upgrade" to low-grade in situ carcinoma (1 ductal and 1 pleomorphic lobular), 5 (17.2%) had "change in diagnosis" to other atypia (ADH/ALH), 15 (51.7%) had additional FEA and 7 (24.2%) had benign tissue without atypia. Both "upgraded" cases had residual microcalcifications on imaging following CNB. There were no upgrades to invasive cancers. In our study, none of 29 with isolated FEA on CNB had invasive cancer on surgical excision. If there are residual microcalcifications or residual lesion after a CNB that shows isolated FEA, excision is warranted, due to the possibility of other atypia (ADH/ALH [17.2%] or DCIS [5.4%]). If there are no residual microcalcifications following CNB, imaging follow-up as an alternative to surgery may be a reasonable option. © 2014 Wiley Periodicals, Inc.

  12. Ultrasound-guided cable-free 13-gauge vacuum-assisted biopsy of non-mass breast lesions

    PubMed Central

    Seo, Jiwoon; Jang, Mijung; Yun, Bo La; Lee, Soo Hyun; Kim, Eun-Kyu; Kang, Eunyoung; Park, So Yeon; Moon, Woo Kyung; Choi, Hye Young; Kim, Bohyoung

    2017-01-01

    Purpose To compare the outcomes of ultrasound-guided core biopsy for non-mass breast lesions by the novel 13-gauge cable-free vacuum-assisted biopsy (VAB) and by the conventional 14-gauge semi-automated core needle biopsy (CCNB). Materials and methods Our institutional review board approved this prospective study, and all patients provided written informed consent. Among 1840 ultrasound-guided percutaneous biopsies performed from August 2013 to December 2014, 145 non-mass breast lesions with suspicious microcalcifications on mammography or corresponding magnetic resonance imaging finding were subjected to 13-gauge VAB or 14-gauge CCNB. We evaluated the technical success rates, average specimen numbers, and tissue sampling time. We also compared the results of percutaneous biopsy and final surgical pathologic diagnosis to analyze the rates of diagnostic upgrade or downgrade. Results Ultrasound-guided VAB successfully targeted and sampled all lesions, whereas CCNB failed to demonstrate calcification in four (10.3%) breast lesions with microcalcification on specimen mammography. The mean sampling time were 238.6 and 170.6 seconds for VAB and CCNB, respectively. No major complications were observed with either method. Ductal carcinoma in situ (DCIS) and atypical ductal hyperplasia (ADH) lesions were more frequently upgraded after CCNB (8/23 and 3/5, respectively) than after VAB (2/26 and 0/4, respectively P = 0.028). Conclusion Non-mass breast lesions were successfully and accurately biopsied using cable-free VAB. The underestimation rate of ultrasound-detected non-mass lesion was significantly lower with VAB than with CCNB. Trial registration CRiS KCT0002267. PMID:28628656

  13. Randomized controlled trial of stereotactic 11-G vacuum-assisted core biopsy for the diagnosis and management of mammographic microcalcification

    PubMed Central

    Maxwell, Anthony J; Morris, Julie; Lim, Yit Y; Harake, MD Janick; Whiteside, Sigrid

    2016-01-01

    Objective: To compare the accuracy of 11-G vacuum-assisted biopsy (VAB) with 14-G core needle biopsy (CNB) to diagnose mammographic microcalcification (MM) and effect on surgical outcomes. Methods: Following ethical approval, VAB and CNB (control) were compared in a randomized prospective study for first-line diagnosis of MM and subsequent surgical outcomes in two breast-screening units. Participants gave written informed consent. Exclusions included comorbidity precluding surgery, prior ipsilateral breast cancer and lesions >40 mm requiring mastectomy as first surgical procedure. The final pathological diagnosis was compared with the initial biopsy result. Quality-of-life (QOL) questionnaires were administered at baseline, 2, 6 and 12 months. 110 participants were required to show a 25% improvement in diagnosis with VAB compared with CNB (90% power). Results: Eligibility was assessed for 787 cases; 129 females recalled from the National Health Service breast screening programme were randomized. Diagnostic accuracy of VAB was 86% and that of CNB was 84%. Using VAB, 2/14 (14.3%) cases upgraded from ductal carcinoma in situ to invasion at surgery and 3/19 (15.8%) using CNB. Following VAB 7/16 (44%) cases required repeat surgery vs 7/24 (29%) after CNB. Both groups recorded significant worsening of functional QOL measures and increased breast pain at follow-up. Conclusion: VAB and CNB were equally accurate at diagnosing MM, and no significant differences in surgical outcomes were observed. Advances in knowledge: The first randomized controlled study of VAB for diagnosis of microcalcification using digital mammography showed no difference in diagnostic accuracy of VAB and CNB, or in the proportion of participants needing repeat non-operative biopsy or second therapeutic operation to treat malignancy. PMID:26654214

  14. Initial Experience with a Wireless Ultrasound-Guided Vacuum-Assisted Breast Biopsy Device

    PubMed Central

    Choi, E-Ryung; Han, Boo-Kyung; Ko, Eun Sook; Ko, Eun Young; Choi, Ji Soo; Cho, Eun Yoon; Nam, Seok Jin

    2015-01-01

    Objective To determine the imaging characteristic of frequent target lesions of wireless ultrasound (US)-guided, vacuum-assisted breast biopsy (Wi-UVAB) and to evaluate diagnostic yield, accuracy and complication of the device in indeterminate breast lesions. Materials and Methods From March 2013 to October 2014, 114 women (age range, 29–76 years; mean age, 50.0 years) underwent Wi-UVAB using a 13-gauge needle (Mammotome Elite®; Devicor Medical Products, Cincinnati, OH, USA). In 103 lesions of 96 women with surgical (n = 81) or follow-up (n = 22) data, complications, biopsy procedure, imaging findings of biopsy targets and histologic results were reviewed. Results Mean number of biopsy cores was 10 (range 4–25). Nine patients developed moderate bleeding. All lesions were suspicious on US, and included non-mass lesions (67.0%) and mass lesions (33.0%). Visible calcifications on US were evident in 57.3% of the target lesions. Most of the lesions (93.2%) were nonpalpable. Sixty-six (64.1%) were malignant [ductal carcinoma in situ (DCIS) rate, 61%] and 12 were high-risk lesions (11.7%). Histologic underestimation was identified in 11 of 40 (27.5%). DCIS cases and in 3 of 9 (33.3%) high-risk lesions necessitating surgery. There was no false-negative case. Conclusion Wi-UVAB is very handy and advantageous for US-unapparent non-mass lesions to diagnose DCIS, especially for calcification cases. Histologic underestimation is unavoidable; still, Wi-UVAB is safe and accurate to diagnose a malignancy. PMID:26630136

  15. Vacuum-assisted stereotactic breast biopsy in the diagnosis and management of suspicious microcalcifications

    PubMed Central

    Esen, Gül; Tutar, Burçin; Uras, Cihan; Calay, Zerrin; İnce, Ümit; Tutar, Onur

    2016-01-01

    PURPOSE We aimed to present our biopsy method and retrospectively evaluate the results, upgrade rate, and follow-up findings of stereotactic vacuum-assisted breast biopsy (VABB) procedures performed in our clinic. METHODS Two hundred thirty-four patients with mammographically detected nonpalpable breast lesions underwent VABB using a 9 gauge biopsy probe and prone biopsy table. A total of 195 patients (median age 53 years, range 32–80 years) with 198 microcalcification-only lesions with a follow-up of at least one year were included in the study. The location of the lesion relative to the needle was determined from the postfire images, and unlike the conventional technique, tissue retrieval was predominantly performed from that location, followed by a complete 360° rotation, if needed. RESULTS The median core number was 8.5. Biopsy results revealed 135 benign, 24 atypical, and 39 malignant lesions. The total upgrade rate at surgery was 7.7% (6.1% for ductal carcinomas in situ and 10.5% for atypical lesions). Patients with benign lesions were followed up for a median period of 27.5 months, with no interval change. At the follow-up, scar formation was seen in 23 patients (17%); three of the scars were remarkable for resembling a malignancy. CONCLUSION Our biposy method is fast and practical, and it is easily tolerated by patients without compromising accuracy. Patients with a diagnosis of atypia still need to undergo a diagnostic surgical procedure and those with a malignancy need to undergo curative surgery, even if the lesion is totally excised at biopsy. VABB may leave a scar in the breast tissue, which may resemble a malignancy, albeit rarely. PMID:27306660

  16. Imprint cytology on microcalcifications excised by vacuum-assisted breast biopsy: a rapid preliminary diagnosis.

    PubMed

    Fotou, Maria; Oikonomou, Vassiliki; Zagouri, Flora; Sergentanis, Theodoros N; Nonni, Afroditi; Athanassiadou, Pauline; Drouveli, Theodora; Atsouris, Efstratios; Kotzia, Evagelia; Zografos, George C

    2007-04-03

    To evaluate imprint cytology in the context of specimens with microcalcifications derived from Vacuum-Assisted Breast Biopsy (VABB). A total of 93 women with microcalcifications BI-RADS 3 and 4 underwent VABB and imprint samples were examined. VABB was performed on Fischer's table using 11-gauge Mammotome vacuum probes. A mammogram of the cores after the procedure confirmed the excision of microcalcifications. For the application of imprint cytology, the cores with microcalcifications confirmed by mammogram were gently rolled against glass microscope slides and thus imprint smears were made. For rapid preliminary diagnosis Diff-Quick stain, modified Papanicolaou stain and May Grunwald Giemsa were used. Afterwards, the core was dipped into a CytoRich Red Collection fluid for a few seconds in order to obtain samples with the use of the specimen wash. After the completion of cytological procedures, the core was prepared for routine histological study. The pathologist was blind to the preliminary cytological results. The cytological and pathological diagnoses were comparatively evaluated. According to the pathological examination, 73 lesions were benign, 15 lesions were carcinomas (12 ductal carcinomas in situ, 3 invasive ductal carcinomas), and 5 lesions were precursor: 3 cases of atypical ductal hyperplasia (ADH) and 2 cases of lobular neoplasia (LN). The observed sensitivity and specificity of the cytological imprints for cancer were 100% (one-sided, 97.5% CI: 78.2%-100%). Only one case of ADH could be detected by imprint cytology. Neither of the two LN cases was detected by the imprints. The imprints were uninformative in 11 out of 93 cases (11.8%). There was no uninformative case among women with malignancy. Imprint cytology provides a rapid, accurate preliminary diagnosis in a few minutes. This method might contribute to the diagnosis of early breast cancer and possibly attenuates patients' anxiety.

  17. Interdisciplinary consensus on the uses and technique of MR-guided vacuum-assisted breast biopsy (VAB): results of a European consensus meeting.

    PubMed

    Heywang-Köbrunner, Sylvia H; Sinnatamby, Ruchi; Lebeau, Annette; Lebrecht, Antje; Britton, Peter D; Schreer, Ingrid

    2009-11-01

    Quality assurance of MR-guided vacuum-assisted breast biopsy (VAB). A consensus was achieved based on the existing literature and experience of an interdisciplinary group comprising European specialists in breast imaging and VAB. Full imaging work-up must be completed according to existing standards before an indication for MR-guided VAB is established. The procedure should be reserved for lesions demonstrable by MRI alone. Acquisition of >24 cores (11-Gauge) should be routinely attempted, with the intention of sufficiently removing small lesions for accurate diagnosis. Following biopsy the patient should be re-imaged to demonstrate the biopsy site and its proximity to the lesion and hence the likely accuracy of the sampling. All patients should be discussed in a regular interdisciplinary conference and a documented consensus reached regarding patient management. Regular audit and review of all MR-guided VAB results and subsequent follow-up are recommended. This consensus includes protocols for the indication, performance parameters, interdisciplinary interpretation therapeutic recommendation, documentation and follow-up of MR-guided VAB. It does not replace official recommendations for percutaneous biopsy.

  18. Sonographically-guided vacuum-assisted biopsy with digital mammography-guided skin marking of suspicious breast microcalcifications: comparison of outcomes with stereotactic biopsy in Asian women.

    PubMed

    Hahn, Soo Yeon; Shin, Jung Hee; Han, Boo-Kyung; Ko, Eun Young

    2011-02-01

    Management of suspicious microcalcifications in very thin breasts is problematic. To evaluate whether sonographically-guided vacuum-assisted biopsy (USVAB) with digital mammography-guided skin marking (DM) for the diagnosis of breast microcalcifications is comparable to stereotactic-guided vacuum-assisted biopsy (SVAB) in Asian women with thin breasts. Retrospective review was performed for 263 consecutive suspicious microcalcification lesions in 261 women who underwent USVAB with DM or SVAB using a prone table between January 2004 and December 2007. SVAB was performed for 190 lesions and USVAB for 73 lesions. Biopsy results were correlated with surgical pathology or followed up for at least 12 months. The diagnostic outcomes of SVAB and USVAB to diagnose microcalcifications were compared. Of 263 lesions, 104 (40%) underwent surgery and 159 (60%) were followed up. SVAB and USVAB groups showed similar final categories or the extent of microcalcifications. US visible lesions were 57 (78%) of 73 at USVAB and 14 (10%) of 140 at SVAB. Of 57 US visible lesions at USVAB, 29 (51%) were not found in initial US but were detectable with the help of DM. Specimen radiographs were negative in 2.1% of lesions at SVAB and in 4.1% at USVAB (p=0.4008). The under-estimation rate and false-negative rate were similar in SVAB and USVAB. US with DM facilitates US visibility of microcalcifications. USVAB with DM can produce acceptable biopsy results, as can SVAB, to diagnose breast microcalcifications in patients with thin breasts.

  19. Vacuum enhanced cutaneous biopsy instrument

    DOEpatents

    Collins, Joseph

    2000-01-01

    A syringe-like disposable cutaneous biopsy instrument equipped with a tubular blade at its lower end, and designed so that a vacuum is created during use, said vacuum serving to retain undeformed a plug of tissue cut from a patient's skin.

  20. Impact of Tumor Localization and Method of Preoperative Biopsy on Sentinel Lymph Node Mapping After Periareolar Nuclide Injection.

    PubMed

    Krammer, Julia; Dutschke, Anja; Kaiser, Clemens G; Schnitzer, Andreas; Gerhardt, Axel; Radosa, Julia C; Brade, Joachim; Schoenberg, Stefan O; Wasser, Klaus

    2016-01-01

    To evaluate whether tumor localization and method of preoperative biopsy affect sentinel lymph node (SLN) detection after periareolar nuclide injection in breast cancer patients. 767 breast cancer patients were retrospectively included. For lymphscintigraphy periareolar nuclide injection was performed and the SLN was located by gamma camera. Patient and tumor characteristics were correlated to the success rate of SLN mapping. SLN marking failed in 9/61 (14.7%) patients with prior vacuum-assisted biopsy and 80/706 (11.3%) patients with prior core needle biopsy. Individually evaluated, biopsy method (p = 0.4) and tumor localization (p = 0.9) did not significantly affect the SLN detection rate. Patients with a vacuum-assisted biopsy of a tumor in the upper outer quadrant had a higher odds ratio of failing in SLN mapping (OR 3.8, p = 0.09) compared to core needle biopsy in the same localization (OR 0.9, p = 0.5). Tumor localization and preoperative biopsy method do not significantly impact SLN mapping with periareolar nuclide injection. However, the failure risk tends to rise if vacuum-assisted biopsy of a tumor in the upper outer quadrant is performed.

  1. Pilot study of radiofrequency ablation therapy without surgical excision for T1 breast cancer: evaluation with MRI and vacuum-assisted core needle biopsy and safety management.

    PubMed

    Yamamoto, Naohito; Fujimoto, Hiroshi; Nakamura, Rikiya; Arai, Manabu; Yoshii, Atsushi; Kaji, Sachiko; Itami, Makiko

    2011-01-01

    There is increasing demand for minimally invasive treatments for small breast cancer mainly because of the desire for better cosmetic results. Although radiofrequency ablation (RFA) is an attractive approach as a local control method for small breast cancer, the problems of histological effectiveness and safety management remain. A total of 29 patients including one patient with bilateral breast cancer were enrolled in this study. The mean tumor size of 30 breasts was 12.8 mm (range 5-19 mm). Under general anesthesia, RFA was performed with a Cool-tip RF system (Valleylab, Boulder, CO, USA) after sentinel lymph node biopsy. Postoperative evaluation with magnetic resonance imaging (MRI) and vacuum-assisted core needle biopsy was done 3-4 weeks after RFA before radiotherapy. Ablated tumors were evaluated with hematoxylin-eosin (H&E) and nicotinamide adenine dinucleotide (NADH)-diaphorase staining. If needed, adjuvant chemo and/or endocrine therapy was performed. All patients except one completed one session of RFA. The mean temperature near the center of the tumors was 89.6°C (range 78-100°C). Postoperative MRI showed the ablated zone clearly in all patients. MRI revealed no hypervascularity of the tumors in the ablated zone. Evaluation with H&E staining of the tumors showed remarkable degenerative changes in only three patients. NADH-diaphorase staining showed no viable tumor tissue in 24 patients out of 26 examined. Three patients received small diameter grade 3 skin burns, two on the outside of the thigh from the grounding pad and one on the breast skin. One patient had a breast lesion like a chronic granulomatous mastitis resulting from overreaction of the ablated zone. RFA therapy appeared relevant and applicable for patients with small breast cancer. Because small skin burns were observed as adverse events, close attention should be paid in the course of the RFA procedure.

  2. Stereotactic core needle breast biopsy marker migration: An analysis of factors contributing to immediate marker migration.

    PubMed

    Jain, Ashali; Khalid, Maria; Qureshi, Muhammad M; Georgian-Smith, Dianne; Kaplan, Jonah A; Buch, Karen; Grinstaff, Mark W; Hirsch, Ariel E; Hines, Neely L; Anderson, Stephan W; Gallagher, Katherine M; Bates, David D B; Bloch, B Nicolas

    2017-11-01

    To evaluate breast biopsy marker migration in stereotactic core needle biopsy procedures and identify contributing factors. This retrospective study analyzed 268 stereotactic biopsy markers placed in 263 consecutive patients undergoing stereotactic biopsies using 9G vacuum-assisted devices from August 2010-July 2013. Mammograms were reviewed and factors contributing to marker migration were evaluated. Basic descriptive statistics were calculated and comparisons were performed based on radiographically-confirmed marker migration. Of the 268 placed stereotactic biopsy markers, 35 (13.1%) migrated ≥1 cm from their biopsy cavity. Range: 1-6 cm; mean (± SD): 2.35 ± 1.22 cm. Of the 35 migrated biopsy markers, 9 (25.7%) migrated ≥3.5 cm. Patient age, biopsy pathology, number of cores, and left versus right breast were not associated with migration status (P> 0.10). Global fatty breast density (P= 0.025) and biopsy in the inner region of breast (P = 0.031) were associated with marker migration. Superior biopsy approach (P= 0.025), locally heterogeneous breast density, and t-shaped biopsy markers (P= 0.035) were significant for no marker migration. Multiple factors were found to influence marker migration. An overall migration rate of 13% supports endeavors of research groups actively developing new biopsy marker designs for improved resistance to migration. • Breast biopsy marker migration is documented in 13% of 268 procedures. • Marker migration is affected by physical, biological, and pathological factors. • Breast density, marker shape, needle approach etc. affect migration. • Study demonstrates marker migration prevalence; marker design improvements are needed.

  3. Vacuum-assisted breast biopsy with 7-gauge, 8-gauge, 9-gauge, 10-gauge, and 11-gauge needles: how many specimens are necessary?

    PubMed

    Preibsch, Heike; Baur, Astrid; Wietek, Beate M; Krämer, Bernhard; Staebler, Annette; Claussen, Claus D; Siegmann-Luz, Katja C

    2015-09-01

    Published national and international guidelines and consensus meetings on the use of vacuum-assisted biopsy (VAB) give different recommendations regarding the required numbers of tissue specimens depending on needle size and imaging method. To evaluate the weights of specimens obtained with different VAB needles to facilitate the translation of the required number of specimens between different breast biopsy systems and needle sizes, respectively. Five different VAB systems and seven different needle sizes were used: Mammotome® (11-gauge (G), 8-G), Vacora® (10-G), ATEC Sapphire™ (9-G), 8-G Mammotome® Revolve™, and EnCor Enspire® (10-G, 7-G). We took 24 (11-G) or 20 (7-10-G) tissue cores from a turkey breast phantom. The mean weight of a single tissue core was calculated for each needle size. A matrix, which allows the translation of the required number of tissue cores for different needle sizes, was generated. Results were compared to the true cumulative tissue weights of consecutively harvested tissue cores. The mean tissue weights obtained with the 11-G / 10-G Vacora® / 10-G Enspire® / 9-G / 8-G Original / 8-G Revolve™ / 7-G needles were 0.084 g / 0.142 g / 0.221 g / 0.121 g / 0.192 g / 0.334 g / 0.363 g, respectively. The calculated required numbers of VAB tissue cores for each needle size build the matrix. For example, the minimum calculated number of required cores according to the current German S3 guideline is 20 / 12 / 8 / 14 / 9 / 5 / 5 for needles of 11-G / 10-G Vacora® / 10-G Enspire® / 9-G / 8-G Original / 8-G Revolve™ / 7-G size. These numbers agree with the true cumulative tissue weights. The presented matrix facilitates the translation of the required number of VAB specimens between different needle sizes and thereby eases the implementation of current guidelines and consensus recommendations into clinical practice. © The Foundation Acta Radiologica 2014.

  4. Impact of stereotactic 11-g vacuum-assisted breast biopsy on cost of diagnosis in Austria.

    PubMed

    Gruber, R; Walter, E; Helbich, T H

    2011-01-01

    To determine the frequency with which stereotactic 11-g vacuum-assisted breast biopsy (11-g SVAB) obviates an open surgical biopsy (OSB), to compare the costs of these two biopsy methods, and to estimate the potential cost savings attributable to 11-g SVAB in the diagnosis of suspicious breast lesions in patients in Austria. We retrospectively reviewed 318 consecutive breast lesions of BI-RADS categories IV and V (microcalcifications n=166; masses n=152) on which 11-g SVAB and OSB were performed. Cost savings were calculated using nationally allowed flat rates and patient charges. Costs were measured from a hospital and a socioeconomic perspective. Common clinical scenarios and sensitivity analyses assessed the extent of achievable cost savings. 11-g SVAB obviated the need for an OSB in 93 (29%) of 318 women. Overall cost savings per 11-g SVAB over OSB were € 242 per case from a hospital perspective, and € 422 per case from a socioeconomic perspective. The use of 11-g SVAB decreased the cost of diagnosis by 7% from a hospital perspective, and by 10% from a socioeconomic perspective. In Austria, annual national savings of over 5 million Euro could be realized with the use of 11-g SVAB for the diagnosis of suspicious breast lesions. Although savings per case are modest, the national health care system realizes significant cost reduction as women benefit from a faster and less invasive approach to diagnosis. Copyright © 2009 Elsevier Ireland Ltd. All rights reserved.

  5. All pure flat atypical atypia lesions of the breast diagnosed using percutaneous vacuum-assisted breast biopsy do not need surgical excision.

    PubMed

    Ouldamer, Lobna; Poisson, Elodie; Arbion, Flavie; Bonneau, Carole; Vildé, Anne; Body, Gilles; Michenet, Patrick

    2018-04-14

    The purposes of this study were to evaluate the outcome of women with pure flat atypical atypia (FEA) diagnosed at vacuum-assisted breast biopsy (VABB) targeting microcalcifications and to determine whether clinical, radiological and pathologic parameters are able to predict which lesions will be upgraded to malignancy. 2414 cases of consecutive VABB for microcalcifications using VA 8-, 10- or 11-Gauge stereotactically guided core biopsy performed between January 2005 and December 2011 from two french breast cancer centers were evaluated. Data of women with VABB-diagnosed pure FEA who underwent either excisional surgery or mammographic follow-up were analyzed. Cases with mass lesions or ipsilateral cancers were excluded. Two pathologists (FA,PM) reviewed the results of procedures performed. Clinical, radiological, as well as histological criteria have been studied in order to determine the correlation between these factors and carcinoma underestimation. This study included 70 cases of pure FEA. Twenty women underwent surgical excision and 50 had clinical and mammographic surveillance only. In three women FEA was upgraded to breast cancer on excision. Clinical and mammographic follow-up for a mean of 56 months ± 27 in the group without excision showed two cancers in the same breast (Intermediate grade DCIS, and invasive ductal carcinoma 84 and 48 months respectively after VABB). Three factors were significantly predictive of underestimation or occurence of cancer for pure FEA when the radiologic lesions are calcifications: age≥ 57 years, radiologic size >10 mm and number of FEA foci ≥4. Copyright © 2018. Published by Elsevier Ltd.

  6. Morphological parameters of flat epithelial atypia (FEA) in stereotactic vacuum-assisted needle core biopsies do not predict the presence of malignancy on subsequent surgical excision.

    PubMed

    Bianchi, Simonetta; Bendinelli, Benedetta; Castellano, Isabella; Piubello, Quirino; Renne, Giuseppe; Cattani, Maria Grazia; Di Stefano, Domenica; Carrillo, Giovanna; Laurino, Licia; Bersiga, Alessandra; Giardina, Carmela; Dante, Stefania; Di Loreto, Carla; Quero, Carmela; Antonacci, Concetta Maria; Palli, Domenico

    2012-10-01

    Flat epithelial atypia (FEA) may represent the earliest precursor of low-grade breast cancer and often coexists with more advanced atypical proliferative breast lesions such as atypical ductal hyperplasia (ADH) and lobular intraepithelial neoplasia (LIN). The present study aims to investigate the association between morphological parameters of FEA and presence of malignancy at surgical excision (SE) and the clinical significance of the association of FEA with ADH and/or LIN. This study included 589 cases of stereotactic 11-gauge vacuum-assisted needle core biopsy (VANCB), reporting a diagnosis of FEA, ADH or LIN with subsequent SE from 14 pathology departments in Italy. Available slides were reviewed, with 114 (19.4 %) showing a malignant outcome at SE. Among the 190 cases of pure FEA, no statistically significant association emerged between clinical-pathological parameters of FEA and risk of malignancy. Logistic regression analyses showed an increased risk of malignancy according to the extension of ADH among the 275 cases of FEA associated with ADH (p = 0.004) and among the 34 cases of FEA associated with ADH and LIN (p = 0.02). In the whole series, a statistically significant increased malignancy risk emerged according to mammographic R1-R3/R4-R5 categories (OR = 1.56; p = 0.04), extension (OR = 1.24; p = 0.04) and grade (OR = 1.94; p = 0.004) of cytological atypia of FEA. The presence of ADH was associated with an increased malignancy risk (OR = 2.85; p < 0.0001). Our data confirm the frequent association of FEA with ADH and/or LIN. A diagnosis of pure FEA on VANCB carries a 9.5 % risk of concurrent malignancy and thus warrants follow-up excision because none of the clinical-pathological parameters predicts which cases will present carcinoma on SE.

  7. The Management Strategy of Benign Solitary Intraductal Papilloma on Breast Core Biopsy.

    PubMed

    Ko, Dayoung; Kang, Eunyoung; Park, So Yeon; Kim, Sun Mi; Jang, Mijung; Yun, Bo La; Chae, Sumin; Jang, Yerang; Kim, Hye Jin; Kim, Sung-Won; Kim, Eun-Kyu

    2017-08-01

    Intraductal papilloma (IDP) is well-known as one of the common benign breast lesions requiring excision. However, treatment of IDP without atypia is controversial. The aim of our study was to determine the proper management of solitary IDP by core needle biopsy (CNB). We retrospectively reviewed patients with solitary IDP confirmed by CNB from March 2003 to March 2015. We collected data about final pathology after excision, as well as clinical, histologic, and radiologic findings at initial diagnosis. The final pathology was categorized as benign or malignant. We evaluated the rate of upgrade to malignancy and factors associated with malignancy. We identified 405 patients who presented benign solitary IDP by CNB. The mean age was 46.1 years (range, 15-86 years). In total, 135 patients underwent surgical excision, and 211 underwent vacuum-assisted excision. Of 346 patients, malignant lesions were found in 8 patients (2.3%): 7 underwent surgical excision, and 1 underwent vacuum-assisted excision. Only the size of IDP was significantly associated with cancer upgrade (P = .003). Our study shows that overall malignancy upgrade rate of benign solitary IDP after excision is very low (2.3%). Even when the size of IDP was less than 1 cm, the upgrade rate to cancer was only 0.9%. Therefore, for patients with small solitary IDP, we recommend close follow-up with ultrasound instead of excision. Copyright © 2017 Elsevier Inc. All rights reserved.

  8. Flat epithelial atypia: conservative management of patients without residual microcalcifications post-vacuum-assisted breast biopsy.

    PubMed

    Schiaffino, Simone; Gristina, Licia; Villa, Alessandro; Tosto, Simona; Monetti, Francesco; Carli, Franca; Calabrese, Massimo

    2018-01-01

    To determine the malignancy rate (defined in this study as stability or absence of malignancy developed on close imaging follow-up post-biopsy) of conservative management in patients with a vacuum-assisted breast biopsy (VAB) diagnosis of flat epithelial atypia (FEA), performed on single group of microcalcifications, completely removed during procedure. This is a retrospective, monocentric, observational study, approved by IRB. Inclusion criteria were: VAB performed on a single group of microcalcifications; the absence of residual calcifications post-VAB; diagnosis of isolated FEA as the most advanced proliferative lesion; radiological follow-up at least of 12 months. The personal history of breast cancer or other high-risk lesions was an exclusion criteria. The patients enrolled were conservatively managed, without surgical excision, through close follow-up: the first two mammographies performed with an interval of 6 months after biopsy, followed by annual mammographic and clinical checks. 48 consecutive patients were enrolled in the study, all females, with age range of 39-76 years (mean 53,3 years) and radiological follow-up range of 13-75 months (mean 41.5 months). All the lesions were classified as BI-RADS 4b. The diameter range of the group of calcifications was 3-10 mm (mean 5, 6 mm). In each patient, 7 to 15 samples (mean 11) were obtained. Among all the patients, there was only one case (2%) of new microcalcifications, developed in the same breast, 26 months after and 8 mm from the site of previous VAB, and interpreted as ADH at surgical excision. All the checks of the other patients were negative. Even with a limited follow-up, we found a malignancy rate lower than 2%, through a defined population. Further studies with bigger number of patients and extended follow-up are needed to reinforce this hypothesis. Advances in knowledge: Surgical excision may not be necessary in patients with VAB diagnosis of isolated FEA, without residual

  9. 49 CFR 570.56 - Vacuum brake assist unit and vacuum brake system.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    .... The following requirements apply to vehicles with vacuum brake assist units and vacuum brake systems. (a) Vacuum brake assist unit integrity. The vacuum brake assist unit shall demonstrate integrity as... maintained on the pedal. (1) Inspection procedure. Stop the engine and apply service brake several times to...

  10. Values of pathological analysis of lost tissue fragments in the vacuum canister during a vacuum-assisted stereotactic biopsy of the breast.

    PubMed

    El Khoury, M; Mesurolle, B; Omeroglu, A; Aldis, A; Kao, E

    2013-05-01

    Determine values of pathological analysis of the canister content during a vacuum-assisted breast biopsy (VABB). Approval was obtained from the ethical committee. Prospective radiological and pathological analyses of the canister content collected during 231 VABBs performed on 231 patients were carried out. χ(2) test was used to determine predictors on canister pathology. The canister pathology was reported separately in 212 cases. It showed only blood in 78/212 (37%) cases and benign (including high-risk lesions) and malignant results in, respectively, 113/212 (53%) and 21/212 (10%) cases. Respective specimen analysis was benign, including high-risk lesions in 162/212 cases (76%) and malignant in 50/212 (24%) cases. Microcalcifications were documented on canister X-ray in 70/231 (30%) cases. There was significant association between the canister and the specimen pathology (p<0.0001). In none of the cases was microcalcifications seen exclusively in the canister content or pathological upgrading found in the canister content compared with the specimen. Small tissue fragments and microcalcifications may be lost in the canister during a VABB. Nevertheless, our results did not show any significant value for systematic analysis of the canister content. There is no added diagnostic value to retrieval and analysis of tissue lost in the canister during a VABB.

  11. Ultrasound-guided fine needle aspiration versus core needle biopsy: comparison of post-biopsy hematoma rates and risk factors.

    PubMed

    Chae, In Hye; Kim, Eun-Kyung; Moon, Hee Jung; Yoon, Jung Hyun; Park, Vivian Y; Kwak, Jin Young

    2017-07-01

    To compare post-biopsy hematoma rates between ultrasound guided-fine needle aspiration and ultrasound guided-core needle biopsy, and to investigate risk factors for post-biopsy hematoma. A total of 5304 thyroid nodules which underwent ultrasound guided biopsy were included in this retrospective study. We compared clinical and US features between patients with and without post-biopsy hematoma. Associations between these features and post-biopsy hematoma were analyzed. Post-biopsy hematoma rate was 0.8% (43/5121) for ultrasound guided-fine needle aspiration and 4.9% (9/183) for ultrasound guided-core needle biopsy (P < 0.001). For ultrasound guided-fine needle aspiration, gender, age, size, presence of vascularity, and suspicious US features were not associated with post-biopsy hematoma according to experience level. Post-biopsy hematoma occurred significantly more with ultrasound guided-core needle biopsy (9/179, 5.0%) than with ultrasound guided-fine needle aspiration (9/1138, 0.8%) (P < 0.001) in experienced performers and ultrasound guided-core needle biopsy was the only significant risk factor for post-biopsy hematoma (adjusted Odds Ratio, 6.458, P < 0.001). Post-biopsy hematoma occurred significantly more in ultrasound guided-core needle biopsy than in ultrasound guided-fine needle aspiration and ultrasound guided-core needle biopsy was the only independent factor of post-biopsy hematoma in thyroid nodules.

  12. Vacuum-assisted venous return reduces blood usage.

    PubMed

    Banbury, Michael K; White, Jennifer A; Blackstone, Eugene H; Cosgrove, Delos M

    2003-09-01

    To determine whether vacuum-assisted venous return has clinical advantages over conventional gravity drainage apart from allowing the use of smaller cannulas and shorter tubing. A total of 150 valve operations were performed at our institution between February and July 1999 using vacuum-assisted venous return with small venous cannulas connected to short tubing. These were compared with (1) 83 valve operations performed between April 1997 and January 1998 using the initial version of vacuum-assisted venous return, and (2) 124 valve operations performed between January and April of 1997 using conventional gravity drainage. Priming volume, hematocrit value, red blood cell usage, and total blood product usage were compared multivariably. These comparisons were covariate and propensity adjusted for dissimilarities between the groups and confirmed by propensity-matched pairs analysis. Priming volume was 1.4 +/- 0.4 L for small-cannula vacuum-assisted venous return, 1.7 +/- 0.4 L for initial vacuum-assisted venous return, and 2.0 +/- 0.4 L for gravity drainage (P <.0001). Smaller priming resulted in higher hematocrit values both at the beginning of cardiopulmonary bypass (27% +/- 5% compared with 26% +/- 4% and 25% +/- 4%, respectively, P <.0001) and at the end (30% +/- 4% compared with 28% +/- 4% and 27% +/- 4%, respectively, P <.0001). Red cell transfusions were used in 17% of the patients having small-cannula vacuum-assisted venous return, 27% of the initial patients having vacuum-assisted venous return, and 37% of the patients having gravity drainage (P =.001); total blood product usage was 19%, 27%, and 39%, respectively (P =.002). Although ministernotomy also was associated with reduced blood product usage (P <.004), propensity matching on type of sternotomy confirmed the association of vacuum-assisted venous return with lowered blood product usage. Vacuum-assisted venous return results in (1) higher hematocrit values during cardiopulmonary bypass and (2) decreased

  13. Breast 3 T-MR imaging: indication for stereotactic vacuum-assisted breast biopsy.

    PubMed

    Yamamoto, Nobuko; Yoshizako, Takeshi; Yoshikawa, Kazuaki; Itakura, Masayuki; Maruyama, Riruke; Kitagaki, Hajime

    2014-01-01

    The purpose of this study was to assess indications for stereotactic vacuum-assisted breast biopsy (SVAB) evaluated by breast 3 T-magnetic resonance (3 T-MR) imaging in patients showing suspicious microcalcifications on mammography and negative ultrasound (US) findings. Fifty-five patients with 55 breast lesions showing suspicious microcalcifications on mammography and negative US findings underwent preoperative 3 T-MR examination including dynamic MR imaging. All patients underwent SVAB within 1 month of MR imaging. The pathological diagnosis of each breast lesion was made by examining tissues obtained by SVAB or radical/partial mastectomy. 3 T-MR imaging findings were evaluated by using the American College of Radiology Breast Imaging Reporting and Data System Atlas (BI-RADS-MRI) and then were correlated with the histopathological findings. When BI-RADS 4 and 5 MR imaging lesions were assumed to be malignant, the usefulness of 3 T-MR imaging was evaluated for diagnosis of impalpable breast lesions by SVAB among lesions with microcalcification detected by mammography and negative US findings. There were 21 malignant lesions, including 5 invasive ductal carcinomas, 16 lesions of ductal carcinoma in situ (DCIS). The sensitivity, specificity, positive predictive value, negative predictive value, and accuracy of 3 T-MR imaging for deciding the indications for SVAB was 90.5%, 97.1%, 95.0%, 94.3%, and 94.5%, respectively. The one-false negative case was a DCIS with small enhancing lesions (0.5 mm). The one false-positive case was ductal adenoma with a linear ductal pattern of enhancement. 3 T-MR imaging may be useful for deciding the indications for SVAB in patients who have breast lesions with microcalcification that are impalpable and are detected by mammography and negative US findings. However, our findings should be considered preliminary and further prospective investigation is required.

  14. Upgrade of ductal carcinoma in situ on core biopsies to invasive disease at final surgery: a retrospective review across the Scottish Breast Screening Programme.

    PubMed

    Sim, Y T; Litherland, J; Lindsay, E; Hendry, P; Brauer, K; Dobson, H; Cordiner, C; Gagliardi, T; Smart, L

    2015-05-01

    To identify factors affecting upgrade rates from B5a (non-invasive) preoperative core biopsies to invasive disease at surgery and ways to improve screening performance. This was a retrospective analysis of 1252 cases of B5a biopsies across all six Scottish Breast Screening Programmes (BSPs), ranging between 2004 and 2012. Final surgical histopathology was correlated with radiological and biopsy factors. Data were analysed using basic Microsoft Excel and standard Chi-squared test used for evaluating statistical significance. B5a upgrade rates for the units ranged from 19.2% to 29.2%, with an average of 23.6%. Mean sizes of invasive tumours were small (3-11 mm). The upgrade rate was significantly higher for cases where the main mammographic abnormality was mass, distortion, or asymmetry, compared with micro-calcification alone (33.2% versus 21.7%, p = 0.0004). The upgrade rate was significantly lower with the use of large-volume vacuum-assisted biopsy (VAB) devices than 14 G core needles (19.9% versus 26%, p = 0.013); in stereotactic than ultrasound-guided biopsies (21.2% versus 36.1%, p < 0.001). Heterogeneity of data from different centres limited evaluation of other potential factors. Upgrade rates are lower for cases with micro-calcification as the sole mammographic feature with the use of VAB devices. Nevertheless, there is variation in practice across Scottish BSPs, including first-line biopsy technique and/or device; and it is of interest that a few centres maintain low upgrade rates despite not using VAB routinely for biopsy of micro-calcification. Copyright © 2015 The Royal College of Radiologists. Published by Elsevier Ltd. All rights reserved.

  15. All atypia diagnosed at stereotactic vacuum-assisted breast biopsy do not need surgical excision.

    PubMed

    de Mascarel, Isabelle; Brouste, Véronique; Asad-Syed, Maryam; Hurtevent, Gabrielle; Macgrogan, Gaëtan

    2011-09-01

    The necessity of excision is debatable when atypia are diagnosed at stereotactic vacuum-assisted breast biopsy (microbiopsy). Among the 287 surgical excisions performed at Institut Bergonié from 1999 to 2009, we selected a case-control study group of 151 excisions; 52 involving all the diagnosed cancers and 99 randomly selected among the 235 excisions without cancer, following atypical microbiopsy (24 flat epithelial atypia; 50 atypical ductal hyperplasia; 14 lobular neoplasia; 63 mixed lesions). Mammographical calcification (type, extension, complete removal) and histological criteria of epithelial atypia (type, number of foci, size/extension), topography and microcalcification extension at microbiopsy were compared according to the presence or absence of cancer at excision. Factors associated with cancer at excision were Breast Imaging Reporting and Data System (BI-RADS5) lesions, large and/or multiple foci of mammographical calcifications, histological type, number, size and extension of atypical foci. Flat epithelial atypia alone was never associated with cancer at excision. BI-RADS5, atypical ductal hyperplasia (alone or predominant) and >3 foci of atypia were identified as independent pejorative factors. There was never any cancer at excision when these pejorative factors were absent (n=31). Presence of one (n=59), two (n=23) or three (n=14) factors was associated with cancer in 24, 15 and 13 cases with an odds ratio=5.8 (95% CI: 3-11.2) for each additional factor. We recommend that mammographical data and histological characteristics be taken into account in the decision-making process after diagnosis of atypia on microbiopsy. With experienced senologists and strict histological criteria, some patients could be spared surgery resulting in significant patient, financial and time advantages.

  16. 21 CFR 864.9125 - Vacuum-assisted blood collection system.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Vacuum-assisted blood collection system. 864.9125... Blood and Blood Products § 864.9125 Vacuum-assisted blood collection system. (a) Identification. A vacuum-assisted blood collection system is a device intended for medical purposes that uses a vacuum to...

  17. 21 CFR 864.9125 - Vacuum-assisted blood collection system.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... 21 Food and Drugs 8 2013-04-01 2013-04-01 false Vacuum-assisted blood collection system. 864.9125... Blood and Blood Products § 864.9125 Vacuum-assisted blood collection system. (a) Identification. A vacuum-assisted blood collection system is a device intended for medical purposes that uses a vacuum to...

  18. 21 CFR 864.9125 - Vacuum-assisted blood collection system.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... 21 Food and Drugs 8 2014-04-01 2014-04-01 false Vacuum-assisted blood collection system. 864.9125... Blood and Blood Products § 864.9125 Vacuum-assisted blood collection system. (a) Identification. A vacuum-assisted blood collection system is a device intended for medical purposes that uses a vacuum to...

  19. 21 CFR 864.9125 - Vacuum-assisted blood collection system.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... 21 Food and Drugs 8 2012-04-01 2012-04-01 false Vacuum-assisted blood collection system. 864.9125... Blood and Blood Products § 864.9125 Vacuum-assisted blood collection system. (a) Identification. A vacuum-assisted blood collection system is a device intended for medical purposes that uses a vacuum to...

  20. 21 CFR 864.9125 - Vacuum-assisted blood collection system.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Vacuum-assisted blood collection system. 864.9125... Blood and Blood Products § 864.9125 Vacuum-assisted blood collection system. (a) Identification. A vacuum-assisted blood collection system is a device intended for medical purposes that uses a vacuum to...

  1. Gleason 6 prostate cancer in one or two biopsy cores can harbor more aggressive disease.

    PubMed

    Katz, Mark H; Shikanov, Sergey; Sun, Maxine; Abdollah, Firas; Budaeus, Lars; Gong, Edward M; Eggener, Scott E; Steinberg, Gary D; Zagaja, Gregory P; Shalhav, Arieh L; Karakiewicz, Pierre I; Zorn, Kevin C

    2011-04-01

    Patients with Gleason (GL) 6 prostate cancer in one or two biopsy cores can be upgraded and/or upstaged at the time of surgery, which may adversely impact long-term outcome. A novel model for prediction of adverse pathologic outcomes was developed using preoperative characteristics. Between 2003 and 2007, 1159 patients underwent robot-assisted radical prostatectomy (RARP) at our institution. GL 6 prostate cancer in one or two biopsy cores was identified in 416 (36%) patients. Logistic regression analyses were used to assess the rate of GL ≥7 and/or extraprostatic extension at RARP. Covariates consisted of age, body mass index (BMI), number of positive cores, greatest percent of cancer in a core (GPC), clinical stage, and preoperative prostate-specific antigen (PSA) level. After backward variable selection, the developed model was internally validated using the area under the curve and subjected to methods of calibration. Respectively, 278 (67%) and 138 (33%) patients had one or two positive biopsy cores. At RARP, 90 (22%) patients were upgraded to GL ≥7 and 37 (9%) had extraprostatic extension. The novel model relied on age, BMI, preoperative PSA level, and GPC for prediction of adverse pathologic outcomes and was 69% accurate. Calibration plot revealed a virtually perfect relationship between predicted and observed probabilities. In patients with GL 6 prostate cancer in one or two biopsy cores, 25% have more ominous pathology at RARP. The model provides an individual assessment of adverse outcomes at surgery. Consequently, it may be considered when counseling patients regarding their management options.

  2. Changing attitudes toward needle biopsies of breast cancer in Shanghai: experience and current status over the past 8 years

    PubMed Central

    Hao, Shuang; Liu, Zhe-Bin; Ling, Hong; Chen, Jia-Jian; Shen, Ju-Ping; Yang, Wen-Tao; Shao, Zhi-Min

    2015-01-01

    Diagnostic patterns in breast cancer have greatly changed over the past few decades, and core needle biopsy (CNB) has become a reliable procedure for detecting breast cancer without invasive surgery. To estimate the changing diagnostic patterns of breast cancer in urban Shanghai, 11,947 women with breast lesions detected by preoperative needle biopsy between January 1995 and December 2012 were selected from the Shanghai Cancer Data base, which integrates information from approximately 50% of breast cancer patients in Shanghai. The CNB procedure uses an automated prone unit, biopsy gun, and 14-gauge needles under freehand or ultrasound guidance and was performed by experienced radiologists and surgeons specializing in needle biopsies. Diagnosis and classification for each patient were independently evaluated by pathologists. Over the indicated 8-year period, biopsy type consisted of 11,947 ultrasound-guided core needle biopsies (UCNBs), 2,015 ultrasound-guided vacuum-assisted biopsies (UVABs), and 654 stereotactic X-ray-guided vacuum-assisted biopsies (XVABs). For all the 11,947 women included in this study, image-guided needle biopsy was the initial diagnostic procedure. Approximately 81.0% of biopsied samples were histopathologically determined to be malignant lesions, 5.5% were determined to be high-risk lesions, and 13.5% were determined to be benign lesions. The number of patients choosing UCNB increased at the greatest rate, and UCNB has become a standard procedure for histodiagnosis because it is inexpensive, convenient, and accurate. The overall false-negative rate of CNB was 1.7%, and the specific false-negative rates for UCNB, UVAB, and XVAB, were 1.7%, 0%, and 0%, respectively. This study suggests that the use of preoperative needle biopsy as the initial breast cancer diagnostic procedure is acceptable in urban Shanghai. Preoperative needle biopsy is now a standard procedure in the Shanghai Cancer Center because it may reduce the number of surgeries

  3. Efficiency of Core Biopsy for BI-RADS-5 Breast Lesions.

    PubMed

    Wolf, Ronald; Quan, Glenda; Calhoun, Kris; Soot, Laurel; Skokan, Laurie

    2008-01-01

    Stereotactic biopsy has proven more cost effective for biopsy of lesions associated with moderately suspicious mammograms. Data regarding selection of stereotactic biopsy (CORE) instead of excisional biopsy (EB) as the first diagnostic procedure in patients with nonpalpable breast lesions and highest suspicion breast imaging-reporting and data system (BI-RADS)-5 mammograms are sparse. Records from a regional health system radiology database were screened for mammograms associated with image-guided biopsy. A total of 182 nonpalpable BI-RADS-5 lesions were sampled in 178 patients over 5 years, using CORE or EB. Initial surgical margins, number of surgeries, time from initial procedure to last related surgical procedure, and hospital and professional charges for related admissions were compared using chi-squared, t-test, and Wilcoxon Mann-Whitney tests. A total of 108 CORE and 74 EB were performed as the first diagnostic procedure. Invasive or in situ carcinoma was diagnosed in 156 (86%) of all biopsies, 95 in CORE and 61 in EB groups. Negative margins of the first surgical procedure were more frequent in CORE (n = 70, 74%) versus EB (n = 17, 28%), p < 0.05. Use of CORE was associated with fewer total surgical procedures per lesion (1.29 +/- 0.05 versus 1.8 +/- 0.05, p < 0.05). Time of initial diagnostic procedure to final treatment did not vary significantly according to group (27 +/- 2 days versus 22 +/- 2 days, CORE versus EB). Mean charges including the diagnostic procedure and all subsequent surgeries were not different between CORE and EB groups ($10,500 +/- 300 versus $11,500 +/- 500, p = 0.08). Use of CORE as the first procedure in patients with highly suspicious mammograms is associated with improved pathologic margins and need for fewer surgical procedures than EB, and should be considered the preferred initial diagnostic approach.

  4. Concordance of Gleason grading with three-dimensional ultrasound systematic biopsy and biopsy core pre-embedding.

    PubMed

    van der Aa, Anouk A M A; Mannaerts, Christophe K; van der Linden, Hans; Gayet, Maudy; Schrier, Bart Ph; Mischi, Massimo; Beerlage, Harrie P; Wijkstra, Hessel

    2018-02-01

    To determine the value of a three-dimensional (3D) greyscale transrectal ultrasound (TRUS)-guided prostate biopsy system and biopsy core pre-embedding method on concordance between Gleason scores of needle biopsies and radical prostatectomy (RP) specimens. Retrospective analysis of prostate biopsies and subsequent RP for PCa in the Jeroen Bosch Hospital, the Netherlands, from 2007 to 2016. Two cohorts were analysed: conventional 2D TRUS-guided biopsies and RP (2007-2013, n = 266) versus 3D TRUS-guided biopsies with pre-embedding (2013-2016, n = 129). The impact of 3D TRUS-guidance with pre-embedding on Gleason score (GS) concordance between biopsy and RP was evaluated using the κ-coefficient. Predictors of biopsy GS 6 upgrading were assessed using logistic regression models. Gleason concordance was comparable between the two cohorts with a κ = 0.44 for the 3D cohort, compared to κ = 0.42 for the 2D cohort. 3D TRUS-guidance with pre-embedding, did not significantly affect the risk of biopsy GS 6 upgrading in univariate and multivariate analysis. 3D TRUS-guidance with biopsy core pre-embedding did not improve Gleason concordance. Improved detection techniques are needed for recognition of low-grade disease upgrading.

  5. Are concurrent systematic cores needed at the time of targeted biopsy in patients with prior negative prostate biopsies?

    PubMed

    Albisinni, S; Aoun, F; Noel, A; El Rassy, E; Lemort, M; Paesmans, M; van Velthoven, R; Roumeguère, T; Peltier, A

    2018-01-01

    MRI-guided targeted biopsies are advised in patients who have undergone an initial series of negative systematic biopsies, in whom prostate cancer (PCa) suspicion remains elevated. The aim of the study was to evaluate whether, in men with prior negative prostate biopsies, systematic cores are also warranted at the time of an MRI-targeted repeat biopsy. We enrolled patients with prior negative biopsy undergoing real time MRI/TRUS fusion guided prostate biopsy at our institute between 2014 and 2016. Patients with at least one index lesion on multiparametric MRI were included. All eligible patients underwent both systematic random biopsies (12-14 cores) and targeted biopsies (2-4 cores). The study included 74 men with a median age of 65 years, PSA level of 9.27ng/mL, and prostatic volume of 45ml. The overall PCa detection rate and the clinically significant cancer detection rate were 56.7% and 39.2%, respectively. Targeted cores demonstrated similar clinically significant PCa detection rate compared to systematic cores (33.8% vs. 28.4%, P=0.38) with significantly less tissue sampling. Indeed, a combination approach was significantly superior to a targeted-only in overall PCa detection (+16.7% overall detection rate, P=0.007). Although differences in clinically significant PCa detection were statistically non-significant (P=0.13), a combination approach did allow detecting 7 extra clinically significant PCas (+13.8%). In patients with elevated PSA and prior negative biopsies, concurrent systematic sampling may be needed at the time of targeted biopsy in order to maximize PCa detection rate. Larger studies are needed to validate our findings. 4. Copyright © 2017 Elsevier Masson SAS. All rights reserved.

  6. Microarray gene expression profiling using core biopsies of renal neoplasia.

    PubMed

    Rogers, Craig G; Ditlev, Jonathon A; Tan, Min-Han; Sugimura, Jun; Qian, Chao-Nan; Cooper, Jeff; Lane, Brian; Jewett, Michael A; Kahnoski, Richard J; Kort, Eric J; Teh, Bin T

    2009-01-01

    We investigate the feasibility of using microarray gene expression profiling technology to analyze core biopsies of renal tumors for classification of tumor histology. Core biopsies were obtained ex-vivo from 7 renal tumors-comprised of four histological subtypes-following radical nephrectomy using 18-gauge biopsy needles. RNA was isolated from these samples and, in the case of biopsy samples, amplified by in vitro transcription. Microarray analysis was then used to quantify the mRNA expression patterns in these samples relative to non-diseased renal tissue mRNA. Genes with significant variation across all non-biopsy tumor samples were identified, and the relationship between tumor and biopsy samples in terms of expression levels of these genes was then quantified in terms of Euclidean distance, and visualized by complete linkage clustering. Final pathologic assessment of kidney tumors demonstrated clear cell renal cell carcinoma (4), oncocytoma (1), angiomyolipoma (1) and adrenalcortical carcinoma (1). Five of the seven biopsy samples were most similar in terms of gene expression to the resected tumors from which they were derived in terms of Euclidean distance. All seven biopsies were assigned to the correct histological class by hierarchical clustering. We demonstrate the feasibility of gene expression profiling of core biopsies of renal tumors to classify tumor histology.

  7. Microarray gene expression profiling using core biopsies of renal neoplasia

    PubMed Central

    Rogers, Craig G.; Ditlev, Jonathon A.; Tan, Min-Han; Sugimura, Jun; Qian, Chao-Nan; Cooper, Jeff; Lane, Brian; Jewett, Michael A.; Kahnoski, Richard J.; Kort, Eric J.; Teh, Bin T.

    2009-01-01

    We investigate the feasibility of using microarray gene expression profiling technology to analyze core biopsies of renal tumors for classification of tumor histology. Core biopsies were obtained ex-vivo from 7 renal tumors—comprised of four histological subtypes—following radical nephrectomy using 18-gauge biopsy needles. RNA was isolated from these samples and, in the case of biopsy samples, amplified by in vitro transcription. Microarray analysis was then used to quantify the mRNA expression patterns in these samples relative to non-diseased renal tissue mRNA. Genes with significant variation across all non-biopsy tumor samples were identified, and the relationship between tumor and biopsy samples in terms of expression levels of these genes was then quantified in terms of Euclidean distance, and visualized by complete linkage clustering. Final pathologic assessment of kidney tumors demonstrated clear cell renal cell carcinoma (4), oncocytoma (1), angiomyolipoma (1) and adrenalcortical carcinoma (1). Five of the seven biopsy samples were most similar in terms of gene expression to the resected tumors from which they were derived in terms of Euclidean distance. All seven biopsies were assigned to the correct histological class by hierarchical clustering. We demonstrate the feasibility of gene expression profiling of core biopsies of renal tumors to classify tumor histology. PMID:19966938

  8. The contribution of cytologic imprints of stereotactically guided core needle biopsies of the breast in the management of patients with mammographic abnormalities.

    PubMed

    Green, R S; Mathew, S

    2001-01-01

    Between 1995 and 1996, 96 consecutive patients with nonpalpable breast lesions detected by abnormal mammogram underwent core needle biopsies under stereotactic guidance at Johns Hopkins Bayview Medical Center. The cytologic diagnoses rendered on touch imprints and the histopathologic diagnoses made on the core needle biopsies were retrospectively reviewed to ascertain the accuracy and the validity of this procedure. These imprints were made of the cores as on-site evaluation in order to assist the radiologist. Separate diagnoses were rendered on the imprints and the cores. Follow-up excisional/open biopsies were then correlated to determine the usefulness of making touch imprints from the core needle biopsies toward the overall management of a patient with an abnormal mammogram. The core needle biopsies were obtained with a 14-gauge needle and biopsy gun. The cytologic diagnoses rendered on touch imprints and histopathologic diagnoses on core needle biopsies were compared and the concordance rate was determined. The subsequent surgical follow-up was analyzed and correlated with the imprint cytology and the core needle biopsy interpretation to ascertain the pathologic outcome. A total of 100 cases were reviewed: 4 patients had two lesions biopsied. Eighty-four cases showed complete cytohistologic correlation, that is, a high concordance rate. These 84 cases were divided into four categories: malignant (24), atypical (2), benign (55), and unsatisfactory (3). Of these concordant cases, there were 34 subsequent excisional biopsies and all except one confirmed the core needle biopsy diagnosis. The exception had a benign touch imprint and core but the excisional biopsy showed multifocal ductal carcinoma in situ. Of the 100 cases, 16 were nonconcordant (the cytologic diagnosis fell into a different category from the histologic diagnosis). Seven of these nonconcordant cases resulted in excisional biopsies and all but one showed the core diagnosis to be correct. The only

  9. Ten-core versus 16-core transrectal ultrasonography guided prostate biopsy for detection of prostatic carcinoma: a prospective comparative study in Indian population

    PubMed Central

    Prakash, V. Surya; Mohan, G. Chandra; Krishnaiah, S. Venkata; Vijaykumar, V.; Babu, G. Ramesh; Reddy, G. Vijaya Bhaskar; Mahaboob, V. S.

    2013-01-01

    Purpose: To compare the cancer detection rate in patients with raised serum prostate-specific antigen (PSA) or abnormal digital rectal examination (DRE) results between the 10-core and the 16-core biopsy techniques in an Indian population. Methods: Between November 2010 and November 2012, 95 men aged >50 years who presented to the Urology Department with lower urinary tract symptoms, elevated serum PSA, and/or abnormal DRE findings underwent transrectal ultrasonography (TRUS)-guided prostate biopsy. A total of 53 patients underwent 10-core biopsy and 42 patients underwent 16-core biopsy. Results: Of the 53 men in the 10-core group, 8 had cancer, whereas in the 16-core biopsy group, 23 of 42 men had cancer. Detection of prostate cancer was significantly higher in patients who underwent 16-core biopsy than in those who underwent 10-core biopsy (P<0.001). Among the 95 men, 44 men had abnormal DRE findings (46.3%), of whom 23 showed cancer (52.27%). Of 51 men with normal DRE findings and elevated PSA, 8 men had malignancy with a cancer detection rate of 15.68%. Among 20 men with PSA between 4.1 and 10 ng/mL, 2 (10%) had cancer. In 31 men with PSA between 10.1 and 20 ng/mL, 3 cancers (9.67%) were detected, and in 44 men with PSA >20 ng/mL, 26 cancers were detected (59.09%). Conclusions: The cancer detection rate with 16-core TRUS-guided biopsy is significantly higher than that with 10-core biopsy (54.76% vs. 15.09%, P<0.001). In patients with both normal and abnormal DRE findings, 16-core biopsy has a better detection rate than the 10-core biopsy protocol. With increasing PSA, there is a high rate of detection of prostate cancer in both 10-core and 16-core biopsy patients. PMID:24392441

  10. Ten-core versus 16-core transrectal ultrasonography guided prostate biopsy for detection of prostatic carcinoma: a prospective comparative study in Indian population.

    PubMed

    Prakash, V Surya; Mohan, G Chandra; Krishnaiah, S Venkata; Vijaykumar, V; Babu, G Ramesh; Reddy, G Vijaya Bhaskar; Mahaboob, V S

    2013-01-01

    To compare the cancer detection rate in patients with raised serum prostate-specific antigen (PSA) or abnormal digital rectal examination (DRE) results between the 10-core and the 16-core biopsy techniques in an Indian population. Between November 2010 and November 2012, 95 men aged >50 years who presented to the Urology Department with lower urinary tract symptoms, elevated serum PSA, and/or abnormal DRE findings underwent transrectal ultrasonography (TRUS)-guided prostate biopsy. A total of 53 patients underwent 10-core biopsy and 42 patients underwent 16-core biopsy. Of the 53 men in the 10-core group, 8 had cancer, whereas in the 16-core biopsy group, 23 of 42 men had cancer. Detection of prostate cancer was significantly higher in patients who underwent 16-core biopsy than in those who underwent 10-core biopsy (P<0.001). Among the 95 men, 44 men had abnormal DRE findings (46.3%), of whom 23 showed cancer (52.27%). Of 51 men with normal DRE findings and elevated PSA, 8 men had malignancy with a cancer detection rate of 15.68%. Among 20 men with PSA between 4.1 and 10 ng/mL, 2 (10%) had cancer. In 31 men with PSA between 10.1 and 20 ng/mL, 3 cancers (9.67%) were detected, and in 44 men with PSA >20 ng/mL, 26 cancers were detected (59.09%). The cancer detection rate with 16-core TRUS-guided biopsy is significantly higher than that with 10-core biopsy (54.76% vs. 15.09%, P<0.001). In patients with both normal and abnormal DRE findings, 16-core biopsy has a better detection rate than the 10-core biopsy protocol. With increasing PSA, there is a high rate of detection of prostate cancer in both 10-core and 16-core biopsy patients.

  11. Benign Intraductal Papilloma without Atypia on Core Needle Biopsy Has a Low Rate of Upgrading to Malignancy after Excision

    PubMed Central

    Han, Song-Hee; Kim, Milim; Chung, Yul Ri; Yun, Bo La; Jang, Mijung; Kim, Sun Mi; Kang, Eunyoung; Kim, Eun-Kyu

    2018-01-01

    Purpose The management of benign intraductal papilloma (IDP) without atypia diagnosed on core needle biopsy (CNB) remains controversial. This study was performed to evaluate the rate of upgrading to malignancy or high-risk lesions after excision and to identify factors associated with upgrading using a large series of benign IDP cases without atypia. Methods We included patients who were diagnosed as having benign IDP without atypia on CNB and underwent surgical or vacuum-assisted excision between 2010 and 2015. We analyzed the clinical, radiologic, and histopathologic features of IDPs that were upgraded to malignancy or high-risk lesions after excision. Results A total of 511 benign IDPs without atypia diagnosed via CNB were identified, of which 398 cases were treated with excision. After reviewing these cases, four cases of high-risk lesions in adjacent tissue on CNB, two cases which were revealed as papilloma with atypia, and nine cases of malignancy in the same breast were excluded. In the remaining 383 cases, the rate of upgrading to malignancy and high-risk lesions after excision was 0.8% and 4.4%, respectively. The presence of concurrent contralateral breast cancer, the presence of symptoms, and multifocality were factors significantly associated with upgrading to malignancy on subsequent excision. Surgical excision rather than vacuum-assisted excision was significantly associated with upgrading to high-risk lesions or malignancy. Conclusion The rate of upgrading to malignancy for benign IDP without atypia was very low, suggesting that close clinical and radiologic observation may be sufficient for patients with benign IDP without atypia on CNB under proper settings. PMID:29628987

  12. Benign Intraductal Papilloma without Atypia on Core Needle Biopsy Has a Low Rate of Upgrading to Malignancy after Excision.

    PubMed

    Han, Song-Hee; Kim, Milim; Chung, Yul Ri; Yun, Bo La; Jang, Mijung; Kim, Sun Mi; Kang, Eunyoung; Kim, Eun-Kyu; Park, So Yeon

    2018-03-01

    The management of benign intraductal papilloma (IDP) without atypia diagnosed on core needle biopsy (CNB) remains controversial. This study was performed to evaluate the rate of upgrading to malignancy or high-risk lesions after excision and to identify factors associated with upgrading using a large series of benign IDP cases without atypia. We included patients who were diagnosed as having benign IDP without atypia on CNB and underwent surgical or vacuum-assisted excision between 2010 and 2015. We analyzed the clinical, radiologic, and histopathologic features of IDPs that were upgraded to malignancy or high-risk lesions after excision. A total of 511 benign IDPs without atypia diagnosed via CNB were identified, of which 398 cases were treated with excision. After reviewing these cases, four cases of high-risk lesions in adjacent tissue on CNB, two cases which were revealed as papilloma with atypia, and nine cases of malignancy in the same breast were excluded. In the remaining 383 cases, the rate of upgrading to malignancy and high-risk lesions after excision was 0.8% and 4.4%, respectively. The presence of concurrent contralateral breast cancer, the presence of symptoms, and multifocality were factors significantly associated with upgrading to malignancy on subsequent excision. Surgical excision rather than vacuum-assisted excision was significantly associated with upgrading to high-risk lesions or malignancy. The rate of upgrading to malignancy for benign IDP without atypia was very low, suggesting that close clinical and radiologic observation may be sufficient for patients with benign IDP without atypia on CNB under proper settings.

  13. Comparison of Battery-Powered and Manual Bone Biopsy Systems for Core Needle Biopsy of Sclerotic Bone Lesions.

    PubMed

    Cohen, Micah G; McMahon, Colm J; Kung, Justin W; Wu, Jim S

    2016-05-01

    The purpose of this study was to compare manual and battery-powered bone biopsy systems for diagnostic yield and procedural factors during core needle biopsy of sclerotic bone lesions. A total of 155 consecutive CT-guided core needle biopsies of sclerotic bone lesions were performed at one institution from January 2006 to November 2014. Before March 2012, lesions were biopsied with manual bone drill systems. After March 2012, most biopsies were performed with a battery-powered system and either noncoaxial or coaxial biopsy needles. Diagnostic yield, crush artifact, CT procedure time, procedure radiation dose, conscious sedation dose, and complications were compared between the manual and battery-powered core needle biopsy systems by Fisher exact test and t test. One-way ANOVA was used for subgroup analysis of the two battery-powered systems for procedure time and radiation dose. The diagnostic yield for all sclerotic lesions was 60.0% (93/155) and was significantly higher with the battery-powered system (73.0% [27/37]) than with the manual systems (55.9% [66/118]) (p = 0.047). There was no significant difference between the two systems in terms of crush artifact, procedure time, radiation dose, conscious sedation administered, or complications. In subgroup analysis, the coaxial battery-powered biopsies had shorter procedure times (p = 0.01) and lower radiation doses (p = 0.002) than the coaxial manual systems, but the noncoaxial battery-powered biopsies had longer average procedure times and higher radiation doses than the coaxial manual systems. In biopsy of sclerotic bone lesions, use of a battery-powered bone drill system improves diagnostic yield over use of a manual system.

  14. MRI/US fusion-guided prostate biopsy allows for equivalent cancer detection with significantly fewer needle cores in biopsy-naive men

    PubMed Central

    Yarlagadda, Vidhush K.; Lai, Win Shun; Gordetsky, Jennifer B.; Porter, Kristin K.; Nix, Jeffrey W.; Thomas, John V.; Rais-Bahrami, Soroush

    2018-01-01

    PURPOSE We aimed to investigate the efficiency and cancer detection of magnetic resonance imaging (MRI)/ultrasonography (US) fusion-guided prostate biopsy in a cohort of biopsy-naive men compared with standard-of-care systematic extended sextant transrectal ultrasonography (TRUS)-guided biopsy. METHODS From 2014 to 2016, 72 biopsy-naive men referred for initial prostate cancer evaluation who underwent MRI of the prostate were prospectively evaluated. Retrospective review was performed on 69 patients with lesions suspicious for malignancy who underwent MRI/US fusion-guided biopsy in addition to systematic extended sextant biopsy. Biometric, imaging, and pathology data from both the MRI-targeted biopsies and systematic biopsies were analyzed and compared. RESULTS There were no significant differences in overall prostate cancer detection when comparing MRI-targeted biopsies to standard systematic biopsies (P = 0.39). Furthermore, there were no significant differences in the distribution of severity of cancers based on grade groups in cases with cancer detection (P = 0.68). However, significantly fewer needle cores were taken during the MRI/US fusion-guided biopsy compared with systematic biopsy (63% less cores sampled, P < 0.001) CONCLUSION In biopsy-naive men, MRI/US fusion-guided prostate biopsy offers equal prostate cancer detection compared with systematic TRUS-guided biopsy with significantly fewer tissue cores using the targeted technique. This approach can potentially reduce morbidity in the future if used instead of systematic biopsy without sacrificing the ability to detect prostate cancer, particularly in cases with higher grade disease. PMID:29770762

  15. The value of forceps biopsy and core needle biopsy in prediction of pathologic complete remission in locally advanced rectal cancer treated with neoadjuvant chemoradiotherapy.

    PubMed

    Tang, Jing-Hua; An, Xin; Lin, Xi; Gao, Yuan-Hong; Liu, Guo-Chen; Kong, Ling-Heng; Pan, Zhi-Zhong; Ding, Pei-Rong

    2015-10-20

    Patients with pathological complete remission (pCR) after treated with neoadjuvant chemoradiotherapy (nCRT) have better long-term outcome and may receive conservative treatments in locally advanced rectal cancer (LARC). The study aimed to evaluate the value of forceps biopsy and core needle biopsy in prediction of pCR in LARC treated with nCRT. In total, 120 patients entered this study. Sixty-one consecutive patients received preoperative forceps biopsy during endoscopic examination. Ex vivo core needle biopsy was performed in resected specimens of another 43 consecutive patients. The accuracy for ex vivo core needle biopsy was significantly higher than forceps biopsy (76.7% vs. 36.1%; p < 0.001). The sensitivity for ex vivo core needle biopsy was significantly lower in good responder (TRG 3) than poor responder (TRG ≤ 2) (52.9% vs. 94.1%; p = 0.017). In vivo core needle biopsy was further performed in 16 patients with good response. Eleven patients had residual cancer cells in final resected specimens, among whom 4 (36.4%) patients were biopsy positive. In conclusion, routine forceps biopsy was of limited value in identifying pCR after nCRT. Although core needle biopsy might further identify a subset of patients with residual cancer cells, the accuracy was not substantially increased in good responders.

  16. The value of forceps biopsy and core needle biopsy in prediction of pathologic complete remission in locally advanced rectal cancer treated with neoadjuvant chemoradiotherapy

    PubMed Central

    Gao, Yuan-Hong; Liu, Guo-Chen; Kong, Ling-Heng; Pan, Zhi-Zhong; Ding, Pei-Rong

    2015-01-01

    Patients with pathological complete remission (pCR) after treated with neoadjuvant chemoradiotherapy (nCRT) have better long-term outcome and may receive conservative treatments in locally advanced rectal cancer (LARC). The study aimed to evaluate the value of forceps biopsy and core needle biopsy in prediction of pCR in LARC treated with nCRT. In total, 120patients entered this study. Sixty-one consecutive patients received preoperative forceps biopsy during endoscopic examination. Ex vivo core needle biopsy was performed in resected specimens of another 43 consecutive patients. The accuracy for ex vivo core needle biopsy was significantly higher than forceps biopsy (76.7% vs. 36.1%; p < 0.001). The sensitivity for ex vivo core needle biopsy was significantly lower in good responder (TRG 3) than poor responder (TRG ≤ 2) (52.9% vs. 94.1%; p = 0.017). In vivo core needle biopsy was further performed in 16 patients with good response. Eleven patients had residual cancer cells in final resected specimens, among whom 4 (36.4%) patients were biopsy positive. In conclusion, routine forceps biopsy was of limited value in identifying pCR after nCRT. Although core needle biopsy might further identify a subset of patients with residual cancer cells, the accuracy was not substantially increased in good responders. PMID:26416245

  17. Fluoroscopy-Guided Percutaneous Vertebral Body Biopsy Using a Novel Drill-Powered Device: Technical Case Series

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Wallace, Adam N., E-mail: wallacea@mir.wustl.edu; Pacheco, Rafael A., E-mail: pachecor@mir.wustl.edu; Tomasian, Anderanik, E-mail: tomasiana@mir.wustl.edu

    2016-02-15

    BackgroundA novel coaxial biopsy system powered by a handheld drill has recently been introduced for percutaneous bone biopsy. This technical note describes our initial experience performing fluoroscopy-guided vertebral body biopsies with this system, compares the yield of drill-assisted biopsy specimens with those obtained using a manual technique, and assesses the histologic adequacy of specimens obtained with drill assistance.MethodsMedical records of all single-level, fluoroscopy-guided vertebral body biopsies were reviewed. Procedural complications were documented according to the Society of Interventional Radiology classification. The total length of bone core obtained from drill-assisted biopsies was compared with that of matched manual biopsies. Pathology reportsmore » were reviewed to determine the histologic adequacy of specimens obtained with drill assistance.ResultsTwenty eight drill-assisted percutaneous vertebral body biopsies met study inclusion criteria. No acute complications were reported. Of the 86 % (24/28) of patients with clinical follow-up, no delayed complications were reported (median follow-up, 28 weeks; range 5–115 weeks). The median total length of bone core obtained from drill-assisted biopsies was 28 mm (range 8–120 mm). This was longer than that obtained from manual biopsies (median, 20 mm; range 5–45 mm; P = 0.03). Crush artifact was present in 11 % (3/28) of drill-assisted biopsy specimens, which in one case (3.6 %; 1/28) precluded definitive diagnosis.ConclusionsA drill-assisted, coaxial biopsy system can be used to safely obtain vertebral body core specimens under fluoroscopic guidance. The higher bone core yield obtained with drill assistance may be offset by the presence of crush artifact.« less

  18. Real-time three-dimensional optical coherence tomography image-guided core-needle biopsy system.

    PubMed

    Kuo, Wei-Cheng; Kim, Jongsik; Shemonski, Nathan D; Chaney, Eric J; Spillman, Darold R; Boppart, Stephen A

    2012-06-01

    Advances in optical imaging modalities, such as optical coherence tomography (OCT), enable us to observe tissue microstructure at high resolution and in real time. Currently, core-needle biopsies are guided by external imaging modalities such as ultrasound imaging and x-ray computed tomography (CT) for breast and lung masses, respectively. These image-guided procedures are frequently limited by spatial resolution when using ultrasound imaging, or by temporal resolution (rapid real-time feedback capabilities) when using x-ray CT. One feasible approach is to perform OCT within small gauge needles to optically image tissue microstructure. However, to date, no system or core-needle device has been developed that incorporates both three-dimensional OCT imaging and tissue biopsy within the same needle for true OCT-guided core-needle biopsy. We have developed and demonstrate an integrated core-needle biopsy system that utilizes catheter-based 3-D OCT for real-time image-guidance for target tissue localization, imaging of tissue immediately prior to physical biopsy, and subsequent OCT imaging of the biopsied specimen for immediate assessment at the point-of-care. OCT images of biopsied ex vivo tumor specimens acquired during core-needle placement are correlated with corresponding histology, and computational visualization of arbitrary planes within the 3-D OCT volumes enables feedback on specimen tissue type and biopsy quality. These results demonstrate the potential for using real-time 3-D OCT for needle biopsy guidance by imaging within the needle and tissue during biopsy procedures.

  19. A study to evaluate the efficacy of image-guided core biopsy in the diagnosis and management of lymphoma--results in 103 biopsies.

    PubMed

    Vandervelde, C; Kamani, T; Varghese, A; Ramesar, K; Grace, R; Howlett, D C

    2008-04-01

    The reason for this study was to evaluate the ability of image-guided core biopsy to replace surgical excision by providing sufficient diagnostic and treatment information. All consecutive image-guided core biopsies in patients with a final diagnosis of lymphoma over a 6-year period at our institution were collected retrospectively. Case notes and pathology reports were reviewed and the diagnostic techniques used were recorded. Pathology reports were graded according to their diagnostic completeness and their ability to provide treatment information. Out of a total of 328 instances of lymphoma, 103 image-guided core biopsies were performed in 96 patients. In 78% of these, the diagnostic information obtained from the biopsy provided a fully graded and subtyped diagnosis of lymphoma with sufficient information to initiate therapy. In the head and neck 67% of core biopsies were fully diagnostic for treatment purposes compared to 91% in the thorax, abdomen and pelvis. Image-guided core biopsy has a number of cost and safety advantages over surgical excision biopsy and in suitable cases it can obviate the need for surgery in cases of suspected lymphoma. This is especially relevant for elderly patients and those with poor performance status.

  20. Benign Papillomas Without Atypia Diagnosed on Core Needle Biopsy: Experience From a Single Institution and Proposed Criteria for Excision

    PubMed Central

    Nayak, Anupma; Carkaci, Selin; Gilcrease, Michael Z.; Liu, Ping; Middleton, Lavinia P.; Bassett, Roland L.; Zhang, Jinxia; Zhang, Hong; Coyne, Robin L.; Bevers, Therese B.; Sneige, Nour; Huo, Lei

    2015-01-01

    The management of benign papilloma (BP) without atypia identified on breast core needle biopsy (CNB) is controversial. We describe the clinicopathologic features of 80 patients with such lesions in our institution, with an upgrade rate to malignancy of 3.8%. A multidisciplinary approach to select patients for surgical excision is recommended. Background The management of benign papilloma (BP) without atypia identified on breast core needle biopsy (CNB) is controversial. In this study, we determined the upgrade rate to malignancy for BPs without atypia diagnosed on CNB and whether there are factors associated with upgrade. Methods Through our pathology database search, we studied 80 BPs without atypia identified on CNB from 80 patients from 1997 to 2010, including 30 lesions that had undergone excision and 50 lesions that had undergone ≥ 2 years of radiologic follow-up. Associations between surgery or upgrade to malignancy and clinical, radiologic, and pathologic features were analyzed. Results Mass lesions, lesions sampled by ultrasound-guided CNB, and palpable lesions were associated with surgical excision. All 3 upgraded cases were mass lesions sampled by ultrasound-guided CNB. None of the lesions with radiologic follow-up only were upgraded to malignancy. The overall upgrade rate was 3.8%. None of the clinical, radiologic, or histologic features were predictive of upgrade. Conclusion Because the majority of patients can be safely managed with radiologic surveillance, a selective approach for surgical excision is recommended. Our proposed criteria for excision include pathologic/radiologic discordance or sampling by ultrasound-guided CNB without vacuum assistance when the patient is symptomatic or lesion size is ≥ 1.5 cm. PMID:24119786

  1. Accuracy and safety of ultrasound-guided percutaneous needle core biopsy of renal masses

    PubMed Central

    Wang, Xianding; Lv, Yuanhang; Xu, Zilin; Aniu, Muguo; Qiu, Yang; Wei, Bing; Li, Xiaohong; Wei, Qiang; Dong, Qiang; Lin, Tao

    2018-01-01

    Abstract Our aim is to determine the sufficiency, accuracy, and safety of ultrasound-guided percutaneous needle core biopsy of renal masses in Chinese patients. Patients who had undergone ultrasound-guided needle core renal mass biopsy from June 2012 to June 2016 at West China Hospital, China were retrospectively reviewed. The information obtained included demographics, mass-related parameters, biopsy indications, technique, complications, pathologic results, and follow-up. Concordance of surgical resection pathology and follow-up data were assessed. Renal mass biopsies were performed in 106 patients. Thirty-nine (36.8%) were asymptomatic. The male/female ratio was 60/46, with a median age of 49.5 years. Median mass size was 8.1 cm (range 1.8–20). Biopsy was performed through a 16-gauge needle, with median cores of 2 taken (range 1–5). Only one significant biopsy-related complication (hemorrhage requiring transfusion) was encountered. An adequate tissue sample was obtained in 97.2% (103/106) of biopsies. Eighty-seven biopsies (82.1%) showed malignant neoplasms, 16 (15.1%) yielded benignity, and 3 (2.8%) were nondiagnostic. After biopsy, 46 patients (43.4%) underwent surgery. Compared with the subsequent mass resection pathology, the biopsy diagnoses were identical in 43 cases. The accuracy rate of biopsy distinguishing malignant from benign lesions was 99.1%, and the rate for determining tumor histological type (excluding the nondiagnostic biopsies) was 95.1%. The sensitivity and specificity in detecting malignancy were 98.9% and 100%, respectively. In several situations, there is still a role for biopsy before intervention. Percutaneous needle core biopsy under ultrasonography guidance is highly accurate and safe, and can determine the proper management of undefinable masses. PMID:29595650

  2. Number of positive preoperative biopsy cores is a predictor of positive surgical margins (PSM) in small prostates after robot-assisted radical prostatectomy (RARP).

    PubMed

    Tuliao, Patrick H; Koo, Kyo C; Komninos, Christos; Chang, Chien H; Choi, Young D; Chung, Byung H; Hong, Sung J; Rha, Koon H

    2015-12-01

    To determine the impact of prostate size on positive surgical margin (PSM) rates after robot-assisted radical prostatectomy (RARP) and the preoperative factors associated with PSM. In all, 1229 men underwent RARP by a single surgeon, from 2005 to August of 2013. Excluded were patients who had transurethral resection of the prostate, neoadjuvant therapy, clinically advanced cancer, and the first 200 performed cases (to reduce the effect of learning curve). Included were 815 patients who were then divided into three prostate size groups: <31 g (group 1), 31-45 g (group 2), >45 g (group 3). Multivariate analysis determined predictors of PSM and biochemical recurrence (BCR). Console time and blood loss increased with increasing prostate size. There were more high-grade tumours in group 1 (group 1 vs group 2 and group 3, 33.9% vs 25.1% and 25.6%, P = 0.003 and P = 0.005). PSM rates were higher in prostates of <45 g with preoperative PSA levels of >20 ng/dL, Gleason score ≥7, T3 tumour, and ≥3 positive biopsy cores. In group 1, preoperative stage T3 [odds ratio (OR) 3.94, P = 0.020] and ≥3 positive biopsy cores (OR 2.52, P = 0.043) were predictive of PSM, while a PSA level of >20 ng/dL predicted the occurrence of BCR (OR 5.34, P = 0.021). No preoperative factors predicted PSM or BCR for groups 2 and 3. A preoperative biopsy with ≥3 positive cores in men with small prostates predicts PSM after RARP. In small prostates with PSM, a PSA level of >20 ng/dL is a predictor of BCR. These factors should guide the choice of therapy and indicate the need for closer postoperative follow-up. © 2014 The Authors BJU International © 2014 BJU International Published by John Wiley & Sons Ltd.

  3. Vacuum-assisted drainage in cardiopulmonary bypass: advantages and disadvantages

    PubMed Central

    de Carvalho Filho, Élio Barreto; Marson, Fernando Augusto de Lima; da Costa, Loredana Nilkenes Gomes; Antunes, Nilson

    2014-01-01

    Systematic review of vacuum assisted drainage in cardiopulmonary bypass, demonstrating its advantages and disadvantages, by case reports and evidence about its effects on microcirculation. We conducted a systematic search on the period 1997-2012, in the databases PubMed, Medline, Lilacs and SciELO. Of the 70 selected articles, 26 were included in the review. Although the vacuum assisted drainage has significant potential for complications and requires appropriate technology and professionalism, prevailed in literature reviewed the concept that vacuum assisted drainage contributed in reducing the rate of transfusions, hemodilutions, better operative field, no significant increase in hemolysis, reduced complications surgical, use of lower prime and of smaller diameter cannulas. PMID:25140478

  4. Vacuum-assisted drainage in cardiopulmonary bypass: advantages and disadvantages.

    PubMed

    Carvalho Filho, Elio Barreto de; Marson, Fernando Augusto de Lima; Costa, Loredana Nilkenes Gomes da; Antunes, Nilson

    2014-01-01

    Systematic review of vacuum assisted drainage in cardiopulmonary bypass, demonstrating its advantages and disadvantages, by case reports and evidence about its effects on microcirculation. We conducted a systematic search on the period 1997-2012, in the databases PubMed, Medline, Lilacs and SciELO. Of the 70 selected articles, 26 were included in the review. Although the vacuum assisted drainage has significant potential for complications and requires appropriate technology and professionalism, prevailed in literature reviewed the concept that vacuum assisted drainage contributed in reducing the rate of transfusions, hemodilutions, better operative field, no significant increase in hemolysis, reduced complications surgical, use of lower prime and of smaller diameter cannulas.

  5. Effectiveness of core biopsy for screen-detected breast lesions under 10 mm: implications for surgical management.

    PubMed

    Farshid, Gelareh; Downey, Peter; Pieterse, Steve; Gill, P Grantley

    2017-09-01

    Technical advances have improved the detection of small mammographic lesions. In the context of mammographic screening, accurate sampling of these lesions by percutaneous biopsy is crucial in limiting diagnostic surgical biopsies, many of which show benign results. Women undergoing core biopsy between January 1997 and December 2007 for <10-mm lesions are included. Patient demographics, imaging features and final histology were tabulated. Performance indices were evaluated. This audit includes 803 lesions <10 mm. Based on core histology, 345 women (43.0%) were immediately cleared of malignancy and 300 (37.4%) were referred for definitive cancer treatment. A further 157 women (19.6%) required diagnostic surgical biopsy because of indefinite or inadequate core results or radiological-pathological discordance, and one woman (0.1%) needed further imaging in 12 months. The open biopsies were malignant in 46 (29.3%) cases. The positive predictive value of malignant core biopsy was 100%. The negative predictive value for benign core results was 97.7%, and the false-negative rate was 2.6%. The lesion could not be visualized after core biopsy in 5.1% of women and in 4.0% of women with malignant core biopsies excision specimens did not contain residual malignancy. Excessive delays in surgery because of complications of core biopsy were not reported. Even at this small size range, core biopsy evaluation of screen-detected breast lesions is highly effective and accurate. A lesion miss rate of 3.1% and under-representation of lesions on core samples highlight the continued need for multidisciplinary collaboration and selective use of diagnostic surgical biopsy. © 2015 Royal Australasian College of Surgeons.

  6. Minimal invasive complete excision of benign breast tumors using a three-dimensional ultrasound-guided mammotome vacuum device.

    PubMed

    Baez, E; Huber, A; Vetter, M; Hackelöer, B-J

    2003-03-01

    The aim of this study was to evaluate the use of three-dimensional (3D) ultrasonography in the complete excision of benign breast tumors using ultrasound-guided vacuum-assisted core-needle biopsy (Mammotome). A protocol for the management of benign breast tumors is proposed. Twenty consecutive patients with sonographically benign breast lesions underwent 3D ultrasound-guided mammotome biopsy under local anesthesia. The indication for surgical biopsy was a solid lesion with benign characteristics on both two-dimensional (2D) and 3D ultrasound imaging, increasing in size over time or causing pain or irritation. Preoperatively, the size of the lesion was assessed using 2D and 3D volumetry. During vacuum biopsy the needle was visualized sonographically in all three dimensions, including the coronal plane. Excisional biopsy was considered complete when no residual tumor tissue could be seen sonographically. Ultrasonographic follow-up examinations were performed on the following day and 3-6 months later to assess residual tissue and scarring. All lesions were histologically benign. Follow-up examinations revealed complete excision of all lesions of < 1.5 mL in volume as assessed by 3D volumetry. 3D ultrasonographic volume assessment was more accurate than 2D using the ellipsoid formula or assessment of the maximum diameter for the prediction of complete excision of the tumor. No bleeding or infections occurred postoperatively and no scarring was seen ultrasonographically on follow-up examinations. Ultrasound-guided vacuum-assisted biopsy allows complete excision of benign breast lesions that are

  7. Determining the Optimal Number of Core Needle Biopsy Passes for Molecular Diagnostics.

    PubMed

    Hoang, Nam S; Ge, Benjamin H; Pan, Lorraine Y; Ozawa, Michael G; Kong, Christina S; Louie, John D; Shah, Rajesh P

    2018-03-01

    The number of core biopsy passes required for adequate next-generation sequencing is impacted by needle cut, needle gauge, and the type of tissue involved. This study evaluates diagnostic adequacy of core needle lung biopsies based on number of passes and provides guidelines for other tissues based on simulated biopsies in ex vivo porcine organ tissues. The rate of diagnostic adequacy for pathology and molecular testing from lung biopsy procedures was measured for eight operators pre-implementation (September 2012-October 2013) and post-implementation (December 2013-April 2014) of a standard protocol using 20-gauge side-cut needles for ten core biopsy passes at a single academic hospital. Biopsy pass volume was then estimated in ex vivo porcine muscle, liver, and kidney using side-cut devices at 16, 18, and 20 gauge and end-cut devices at 16 and 18 gauge to estimate minimum number of passes required for adequate molecular testing. Molecular diagnostic adequacy increased from 69% (pre-implementation period) to 92% (post-implementation period) (p < 0.001) for lung biopsies. In porcine models, both 16-gauge end-cut and side-cut devices require one pass to reach the validated volume threshold to ensure 99% adequacy for molecular characterization, while 18- and 20-gauge devices require 2-5 passes depending on needle cut and tissue type. Use of 20-gauge side-cut core biopsy needles requires a significant number of passes to ensure diagnostic adequacy for molecular testing across all tissue types. To ensure diagnostic adequacy for molecular testing, 16- and 18-gauge needles require markedly fewer passes.

  8. Window-assisted nanosphere lithography for vacuum micro-nano-electronics

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Li, Nannan; Institute of Electronic Engineering, Chinese Academy of Engineering Physics, Mianyang, 621900; Pang, Shucai

    2015-04-15

    Development of vacuum micro-nano-electronics is quite important for combining the advantages of vacuum tubes and solid-state devices but limited by the prevailing fabricating techniques which are expensive, time consuming and low-throughput. In this work, window-assisted nanosphere lithography (NSL) technique was proposed and enabled the low-cost and high-efficiency fabrication of nanostructures for vacuum micro-nano-electronic devices, thus allowing potential applications in many areas. As a demonstration, we fabricated high-density field emitter arrays which can be used as cold cathodes in vacuum micro-nano-electronic devices by using the window-assisted NSL technique. The details of the fabricating process have been investigated. This work provided amore » new and feasible idea for fabricating nanostructure arrays for vacuum micro-nano-electronic devices, which would spawn the development of vacuum micro-nano-electronics.« less

  9. Are 10-, 10-12-, or > 12-mm prostate biopsy core quality control cutoffs reasonable?

    PubMed

    Sanches, Brunno C F; Lalli, Ana Luiza; Azal Neto, Wilmar; Billis, Athanase; Reis, Leonardo Oliveira

    2018-07-01

    To explore the role of prostate biopsy core length on prediction of index tumor clinical significance and localization on radical prostatectomy (RP) and time to recurrence, hypothesizing 10-, 10-12-, or > 12-mm minimum core as potential biopsy quality control. Assessed 2424 prostate biopsy cores and corresponding RP of 202 patients submitted to the first set of 12 cores prostate biopsy between 2010 and 2015. Analyzed biopsy core length, age, prostate volume (PV), free and total PSA ratio, PSA density, RP index tumor clinical significance, extension, localization, surgical margins, and cancer control. Prostate biopsy confronted to surgical specimens defined Gleason grade-grouping system (1-5) agreement. Median age was 63.7 years, PSA 10.1 ng/dl, PSA density 28%, and mean follow-up 5 years. Recurrence was identified in 64 (31.7%) patients and predicted by PSA > 10 at time of diagnosis (p = 0.008), seminal vesicle invasion (p = 0.0019), core tumor percentage (p = 0.033), and tumor localization predominantly in the prostate base (p = 0017). The mean core length was longer in index tumor positive cores (p = 0.043) and in tumors classified as clinically insignificant (p = 0.011), without impact on tumor localization (basal vs apical p = 0.592; left vs. right p = 0.320). Biopsy core length categories (≤ 10, 10-12 and > 12 mm) did not significantly impact Gleason grade-grouping agreement or time to recurrence (p > 0.05). Core length was not significantly different in all Gleason grade-groupings 1-5 (p = 0.312). Prostate biopsy core length impacts tumor characterization; however, 10 mm minimum core length and even 10-12- and > 12-mm categories failed as a biopsy quality control in our data.

  10. Concordance between fine-needle aspiration and core biopsies for osseous lesions by lesion imaging appearance and CT attenuation.

    PubMed

    Li, John; Weissberg, Zoe; Bevilacqua, Thomas A; Yu, Gordon; Weber, Kristy; Sebro, Ronnie

    2018-04-01

    To compare the concordance between fine-needle aspiration and core biopsies for osseous lesions by lesion imaging appearance and CT attenuation. Retrospective review of 215 FNAs of osseous lesions performed in conjunction with core biopsy at our institution over a 6-year period (2011-2016). FNAs were interpreted independently of core biopsies. We assessed if FNA in conjunction with core biopsy increased diagnostic accuracy compared to core biopsy alone. We also calculated the concordance between FNA and core biopsy by lesion appearance, lesion CT attenuation, lesion histology, lesion location and FNA needle gauge size. Core biopsy alone provided the diagnosis in 207/215 cases (96.3%), however, the FNA provided the diagnosis in the remaining 8/215 cases (3.7%) where the core biopsy was non-diagnostic. There were 154 (71.6%) lytic lesions, 21 (9.8%) blastic lesions, 25 (11.6%) mixed lytic and blastic lesions and 15 (7.0%) lesions that were neither lytic nor blastic. The concordance between FNA and core biopsy for lytic osseous lesions (136/154 cases, 88.3%) was statistically significantly higher than that for blastic osseous lesions (13/21 cases, 61.9%) [P = 4.2 × 10 -3 ; 95% CI (0.02, 0.50)]. The concordance between FNA and core biopsy was higher for low-attenuation- (110/126) than high-attenuation (58/77) lesions (P = 0.028). The concordance between FNA and core biopsy was also higher for metastases (102/119 cases, 85.7%) than non-metastases (78/96, 81.3%) [P = 0.487; 95% CI (- 0.15, 0.065)]. There was no difference in the rate of concordance between FNA and core biopsy by lesion location or FNA needle gauge size (P > 0.05). FNA with core biopsy increases diagnostic rate compared to core biopsy alone or FNA alone. The concordance between FNA and core biopsy is higher for lytic lesions than for blastic lesions; and higher for low-attenuation lesions than for high-attenuation lesions.

  11. Targeted vs systematic robot-assisted transperineal magnetic resonance imaging-transrectal ultrasonography fusion prostate biopsy.

    PubMed

    Mischinger, Johannes; Kaufmann, Sascha; Russo, Giorgio I; Harland, Niklas; Rausch, Steffen; Amend, Bastian; Scharpf, Marcus; Loewe, Lorenz; Todenhoefer, Tilman; Notohamiprodjo, Mike; Nikolaou, Konstantin; Stenzl, Arnulf; Bedke, Jens; Kruck, Stephan

    2018-05-01

    To evaluate the performance of transperineal robot-assisted (RA) targeted (TB) and systematic (SB) prostate biopsy in primary and repeat biopsy settings. Patients underwent RA biopsy between 2014 and 2016. Before RA-TB, multiparametric magnetic resonance imaging (mpMRI) was performed. Prostate lesions were scored (Prostate Imaging, Reporting and Data System, version 2) and used for RA-TB planning. In addition, RA-SB was performed. Available, whole-gland pathology was analysed. In all, 130 patients were biopsy naive and 72 had had a previous negative transrectal ultrasonography-guided biopsy. In total, 202 patients had suspicious mpMRI lesions. Clinically significant prostate cancer was found in 85% of all prostate cancer cases (n = 123). Total and clinically significant prostate cancer detection rates for RA-TB vs RA-SB were not significantly different at 77% vs 84% and 80% vs 82%, respectively. RA-TB demonstrated a better sampling performance compared to RA-SB (26.4% vs 13.9%; P < 0.001). Transperineal RA-TB and -SB showed similar clinically significant prostate cancer detection rates in primary and repeat biopsy settings. However, RA-TB offered a 50% reduction in biopsy cores. Omitting RA-SB is associated with a significant risk of missing clinically significant prostate cancer. © 2017 The Authors BJU International © 2017 BJU International Published by John Wiley & Sons Ltd.

  12. Management of hidradenitis suppurativa wounds with an internal vacuum-assisted closure device.

    PubMed

    Chen, Y Erin; Gerstle, Theodore; Verma, Kapil; Treiser, Matthew D; Kimball, Alexandra B; Orgill, Dennis P

    2014-03-01

    Hidradenitis suppurativa is a chronic, debilitating disease that is difficult to treat. Once medical management fails, wide local excision offers the best chance for cure. However, the resultant wound often proves too large or contaminated for immediate closure. The authors performed a retrospective chart review of hidradenitis cases managed surgically between 2005 and 2010. Data collected included patient characteristics, management method, and outcomes. Approximately half of the patients received internal vacuum-assisted closure therapy using the vacuum-assisted closure system and delayed closure and half of the patients received immediate primary closure at the time of their excision. Delayed closure consisted of closing the majority of the wound in a linear fashion following internal vacuum-assisted closure while accepting healing by means of secondary intention for small wound areas. Patients managed with internal vacuum-assisted closure had wounds on average four times larger in area than patients managed without internal vacuum-assisted closure. In both groups, all wounds were eventually closed primarily. Healing times averaged 2.2 months with internal vacuum-assisted closure and 2.7 months without. At an average follow-up time of 2.3 months, all patients with internal vacuum-assisted closure had no recurrence of their local disease. Severe hidradenitis presents a treatment challenge, as surgical excisions are often complicated by difficult closures and unsatisfactory recurrence rates. This study demonstrates that wide local excision with reasonable outcomes can be achieved using accelerated delayed primary closure. This method uses internal vacuum-assisted closure as a bridge between excision and delayed primary closure, facilitating closure without recurrence in large, heavily contaminated wounds. Therapeutic, III.

  13. Discordance between location of positive cores in biopsy and location of positive surgical margin following radical prostatectomy.

    PubMed

    Kim, Ji Won; Park, Hyoung Keun; Kim, Hyeong Gon; Ham, Dong Yeub; Paick, Sung Hyun; Lho, Yong Soo; Choi, Woo Suk

    2015-10-01

    We compared location of positive cores in biopsy and location of positive surgical margin (PSM) following radical prostatectomy. This retrospective analysis included patients who were diagnosed as prostate cancer by standard 12-core transrectal ultrasonography guided prostate biopsy, and who have PSM after radical prostatectomy. After exclusion of number of biopsy cores <12, and lack of biopsy location data, 46 patients with PSM were identified. Locations of PSM in pathologic specimen were reported as 6 difference sites (apex, base and lateral in both sides). Discordance of biopsy result and PSM was defined when no positive cores in biopsy was identified at the location of PSM. Most common location of PSM were right apex (n=21) and left apex (n=15). Multiple PSM was reported in 21 specimens (45.7%). In 32 specimens (69.6%) with PSM, one or more concordant positive biopsy cores were identified, but 14 specimens (28%) had no concordant biopsy cores at PSM location. When discordant rate was separated by locations of PSM, right apex PSM had highest rate of discordant (38%). The discordant group had significantly lower prostate volume and lower number of positive cores in biopsy than concordant group. This study showed that one fourth of PSM occurred at location where tumor was not detected at biopsy and that apex PSM had highest rate of discordant. Careful dissection to avoid PSM should be performed in every location, including where tumor was not identified in biopsy.

  14. Core Needle Lung Biopsy Specimens: Adequacy for EGFR and KRAS Mutational Analysis

    PubMed Central

    Zakowski, Maureen F.; Pao, William; Thornton, Raymond H.; Ladanyi, Marc; Kris, Mark G.; Rusch, Valerie W.; Rizvi, Naiyer A.

    2013-01-01

    OBJECTIVE The purpose of this study was to prospectively compare the adequacy of core needle biopsy specimens with the adequacy of specimens from resected tissue, the histologic reference standard, for mutational analysis of malignant tumors of the lung. SUBJECTS AND METHODS The first 18 patients enrolled in a phase 2 study of gefitinib for lung cancer in July 2004 through August 2005 underwent CT- or fluoroscopy-guided lung biopsy before the start of gefitinib therapy. Three weeks after gefitinib therapy, the patients underwent lung tumor resection. The results of EGFR and KRAS mutational analysis of the core needle biopsy specimens were compared with those of EGFR and KRAS mutational analysis of the surgical specimens. RESULTS Two specimens were unsatisfactory for mutational analysis. The results of mutational assay results of the other 16 specimens were the same as those of analysis of the surgical specimens obtained an average of 31 days after biopsy. CONCLUSION Biopsy with small (18- to 20-gauge) core needles can yield sufficient and reliable samples for mutational analysis. This technique is likely to become an important tool with the increasing use of pharmacotherapy based on the genetics of specific tumors in individual patients. PMID:20028932

  15. Performance characteristics of prostate-specific antigen density and biopsy core details to predict oncological outcome in patients with intermediate to high-risk prostate cancer underwent robot-assisted radical prostatectomy.

    PubMed

    Yashi, Masahiro; Nukui, Akinori; Tokura, Yuumi; Takei, Kohei; Suzuki, Issei; Sakamoto, Kazumasa; Yuki, Hideo; Kambara, Tsunehito; Betsunoh, Hironori; Abe, Hideyuki; Fukabori, Yoshitatsu; Nakazato, Yoshimasa; Kaji, Yasushi; Kamai, Takao

    2017-06-23

    Many urologic surgeons refer to biopsy core details for decision making in cases of localized prostate cancer (PCa) to determine whether an extended resection and/or lymph node dissection should be performed. Furthermore, recent reports emphasize the predictive value of prostate-specific antigen density (PSAD) for further risk stratification, not only for low-risk PCa, but also for intermediate- and high-risk PCa. This study focused on these parameters and compared respective predictive impact on oncologic outcomes in Japanese PCa patients. Two-hundred and fifty patients with intermediate- and high-risk PCa according to the National Comprehensive Cancer Network (NCCN) classification, that underwent robot-assisted radical prostatectomy at a single institution, and with observation periods of longer than 6 months were enrolled. None of the patients received hormonal treatments including antiandrogens, luteinizing hormone-releasing hormone analogues, or 5-alpha reductase inhibitors preoperatively. PSAD and biopsy core details, including the percentage of positive cores and the maximum percentage of cancer extent in each positive core, were analyzed in association with unfavorable pathologic results of prostatectomy specimens, and further with biochemical recurrence. The cut-off values of potential predictive factors were set through receiver-operating characteristic curve analyses. In the entire cohort, a higher PSAD, the percentage of positive cores, and maximum percentage of cancer extent in each positive core were independently associated with advanced tumor stage ≥ pT3 and an increased index tumor volume > 0.718 ml. NCCN classification showed an association with a tumor stage ≥ pT3 and a Gleason score ≥8, and the attribution of biochemical recurrence was also sustained. In each NCCN risk group, these preoperative factors showed various associations with unfavorable pathological results. In the intermediate-risk group, the percentage of positive cores showed

  16. Breast epithelium procurement from stereotactic core biopsy washings: flow cytometry-sorted cell count analysis.

    PubMed

    Stoler, Daniel L; Stewart, Carleton C; Stomper, Paul C

    2002-02-01

    Molecular studies of breast lesions have been constrained by difficulties in procuring adequate tissues for analyses. Standard procedures are restricted to larger, palpable masses or the use of paraffin-embedded materials, precluding facile procurement of fresh specimens of early lesions. We describe a study to determine the yield and characteristics of sorted cell populations retrieved in core needle biopsy specimen rinses from a spectrum of breast lesions. Cells from 114 consecutive stereotactic core biopsies of mammographic lesions released into saline washes were submitted for flow cytometric analysis. For each specimen, epithelial cells were separated from stromal and blood tissue based on the presence of cytokeratin 8 and 18 markers. Epithelial cell yields based on pathological diagnoses of the biopsy specimen, patient age, and mammographic appearance of the lesion were determined. Biopsies containing malignant lesions yielded significantly higher numbers of cells than were obtained from benign lesion biopsies. Significantly greater cell counts were observed from lesions from women age 50 or above compared with those of younger women. Mammographic density surrounding the biopsy site, the mammographic appearance of the lesion, and the number of cores taken at the time of biopsy appeared to have little effect on the yield of epithelial cells. We demonstrate the use of flow cytometric sorting of stereotactic core needle biopsy washes from lesions spanning the spectrum of breast pathology to obtain epithelial cells in sufficient numbers to meet the requirements of a variety of molecular and genetic analyses.

  17. Prostate biopsies assisted by comanipulated probe-holder: first in man.

    PubMed

    Vitrani, Marie-Aude; Baumann, Michael; Reversat, David; Morel, Guillaume; Moreau-Gaudry, Alexandre; Mozer, Pierre

    2016-06-01

    A comanipulator for assisting endorectal prostate biopsies is evaluated through a first-in-man clinical trial. This lightweight system, based on conventional robotic components, possesses six degrees of freedom. It uses three electric motors and three brakes. It features a free mode, where its low friction and inertia allow for natural manipulation of the probe and a locked mode, exhibiting both a very low stiffness and a high steady-state precision. Clinical trials focusing on the free mode and the locked mode of the robot are presented. The objective was to evaluate the practical usability and performance of the robot during clinical procedures. A research protocol for a prospective randomized clinical trial has been designed. Its specific goal was to compare the accuracy of biopsies performed with and without the assistance of the comanipulator. The accuracy is compared between biopsies performed with and without the assistance of the comanipulator, across the 10 first patients included in the trial. Results show a statistically significant increase in the precision.

  18. Atypia on breast core needle biopsies: reproducibility and significance.

    PubMed

    Darvishian, Farbod; Singh, Baljit; Simsir, Aylin; Ye, Weimin; Cangiarella, Joan F

    2009-01-01

    This study analyzes the interobserver variability in interpreting atypia on breast core needle biopsies and in each category of atypia calculates the upgrade risk of carcinoma in the subsequent surgical excision. We identified 51 cases of atypia on breast core needle biopsies performed at our institution from January 2003 to August 2006. The atypia was classified into 4 categories: atypical ductal hyperplasia (ADH), atypical lobular hyperplasia (ALH), flat epithelial atypia (FEA), and atypia of undetermined significance (AUS). After a tutorial session, these cases were independently reviewed by four pathologists, whose overall multi-rater kappa value for agreement on different categories of atypia was 0.79 (95% CI, 0.69-0.89), which is within the substantial agreement range. The upgrade risk in each category of atypia was as follows: ADH 20% (p = 0.04); ALH 10% (p = 0.6); FEA 16.6% (p = 0.23), and AUS 100% (p = 0.96). Based on our findings, we conclude that follow-up excision should be performed after a diagnosis of ADH. The upgrade risk did not reach statistical significance in ALH or FEA. Although follow-up excision cannot be strongly recommended in ALH and FEA, it should be considered since the upgrade risk is not negligible. Strict adherence to the diagnostic criteria and tutorial sessions can help pathologists to achieve substantial agreement in interpreting atypia on breast core needle biopsies.

  19. Needle Biopsy

    MedlinePlus

    ... needle biopsy procedures include fine-needle aspiration and core needle biopsy. Needle biopsy may be used to ... hollow needle to draw cells from your body. Core needle biopsy. This type of needle biopsy uses ...

  20. Diagnostic performance and safety of a three-dimensional 14-core systematic biopsy method.

    PubMed

    Takeshita, Hideki; Kawakami, Satoru; Numao, Noboru; Sakura, Mizuaki; Tatokoro, Manabu; Yamamoto, Shinya; Kijima, Toshiki; Komai, Yoshinobu; Saito, Kazutaka; Koga, Fumitaka; Fujii, Yasuhisa; Fukui, Iwao; Kihara, Kazunori

    2015-03-01

    To investigate the diagnostic performance and safety of a three-dimensional 14-core biopsy (3D14PBx) method, which is a combination of the transrectal six-core and transperineal eight-core biopsy methods. Between December 2005 and August 2010, 1103 men underwent 3D14PBx at our institutions and were analysed prospectively. Biopsy criteria included a PSA level of 2.5-20 ng/mL or abnormal digital rectal examination (DRE) findings, or both. The primary endpoint of the study was diagnostic performance and the secondary endpoint was safety. We applied recursive partitioning to the entire study cohort to delineate the unique contribution of each sampling site to overall and clinically significant cancer detection. Prostate cancer was detected in 503 of the 1103 patients (45.6%). Age, family history of prostate cancer, DRE, PSA, percentage of free PSA and prostate volume were associated with the positive biopsy results significantly and independently. Of the 503 cancers detected, 39 (7.8%) were clinically locally advanced (≥cT3a), 348 (69%) had a biopsy Gleason score (GS) of ≥7, and 463 (92%) met the definition of biopsy-based significant cancer. Recursive partitioning analysis showed that each sampling site contributed uniquely to both the overall and the biopsy-based significant cancer detection rate of the 3D14PBx method. The overall cancer-positive rate of each sampling site ranged from 14.5% in the transrectal far lateral base to 22.8% in the transrectal far lateral apex. As of August 2010, 210 patients (42%) had undergone radical prostatectomy, of whom 55 (26%) were found to have pathologically non-organ-confined disease, 174 (83%) had prostatectomy GS ≥7 and 185 (88%) met the definition of prostatectomy-based significant cancer. This is the first prospective analysis of the diagnostic performance of an extended biopsy method, which is a simplified version of the somewhat redundant super-extended three-dimensional 26-core biopsy. As expected, each sampling

  1. Greater Biopsy Core Number Is Associated With Improved Biochemical Control in Patients Treated With Permanent Prostate Brachytherapy

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Bittner, Nathan; Merrick, Gregory S., E-mail: gmerrick@urologicresearchinstitute.or; Galbreath, Robert W.

    2010-11-15

    Purpose: Standard prostate biopsy schemes underestimate Gleason score in a significant percentage of cases. Extended biopsy improves diagnostic accuracy and provides more reliable prognostic information. In this study, we tested the hypothesis that greater biopsy core number should result in improved treatment outcome through better tailoring of therapy. Methods and Materials: From April 1995 to May 2006, 1,613 prostate cancer patients were treated with permanent brachytherapy. Patients were divided into five groups stratified by the number of prostate biopsy cores ({<=}6, 7-9, 10-12, 13-20, and >20 cores). Biochemical progression-free survival (bPFS), cause-specific survival (CSS), and overall survival (OS) were evaluatedmore » as a function of core number. Results: The median patient age was 66 years, and the median preimplant prostate-specific antigen was 6.5 ng/mL. The overall 10-year bPFS, CSS, and OS were 95.6%, 98.3%, and 78.6%, respectively. When bPFS was analyzed as a function of core number, the 10-year bPFS for patients with >20, 13-20, 10-12, 7-9 and {<=}6 cores was 100%, 100%, 98.3%, 95.8%, and 93.0% (p < 0.001), respectively. When evaluated by treatment era (1995-2000 vs. 2001-2006), the number of biopsy cores remained a statistically significant predictor of bPFS. On multivariate analysis, the number of biopsy cores was predictive of bPFS but did not predict for CSS or OS. Conclusion: Greater biopsy core number was associated with a statistically significant improvement in bPFS. Comprehensive regional sampling of the prostate may enhance diagnostic accuracy compared to a standard biopsy scheme, resulting in better tailoring of therapy.« less

  2. Hematoma formation during breast core needle biopsy in women taking antithrombotic therapy.

    PubMed

    Chetlen, Alison L; Kasales, Claudia; Mack, Julie; Schetter, Susann; Zhu, Junjia

    2013-07-01

    The purpose of this study was to compare hematoma formation after breast core needle biopsy performed on patients undergoing and those not undergoing concurrent antithrombotic therapy. A prospective assessment of core needle biopsies (stereotactic, ultrasound guided, or MRI guided) performed on patients enrolled between September 2011 and July 2012 formed the basis of this study. Postprocedure mediolateral and craniocaudal mammograms were evaluated for the presence and size of hematomas. Patients were clinically evaluated for complications 24-48 hours after the procedure through telephone call or face-to-face consultation. Needle size, type of biopsy, and presence of hematoma and documented complications were correlated with use of antithrombotic agents (including aspirin, warfarin, clopidogrel, and daily nonsteroidal antiinflammatory medications). No clinically significant hematomas or bleeding complications were found. Eighty-nine of 617 (14.4%) non-clinically significant hematomas were detected on postprocedure mammograms. The probability of development of a non-clinically significant hematoma was 21.6% for patients taking antithrombotics and 13.0% for those not taking antithrombotics. Concurrent antithrombotic therapy and larger needle gauge were significant factors contributing to the probability of hematoma formation. The volume of the hematoma was not related to needle gauge or presence of antithrombotic therapy. No clinically significant hematomas were found. Because there are potential life-threatening risks to stopping antithrombotic therapy before breast biopsy, withholding antithrombotic therapy for core needle breast biopsy is not recommended because the incidence of non-clinically significant hematoma is low.

  3. CT fluoroscopy-guided robotically-assisted lung biopsy

    NASA Astrophysics Data System (ADS)

    Xu, Sheng; Fichtinger, Gabor; Taylor, Russell H.; Banovac, Filip; Cleary, Kevin

    2006-03-01

    Lung biopsy is a common interventional radiology procedure. One of the difficulties in performing the lung biopsy is that lesions move with respiration. This paper presents a new robotically assisted lung biopsy system for CT fluoroscopy that can automatically compensate for the respiratory motion during the intervention. The system consists of a needle placement robot to hold the needle on the CT scan plane, a radiolucent Z-frame for registration of the CT and robot coordinate systems, and a frame grabber to obtain the CT fluoroscopy image in real-time. The CT fluoroscopy images are used to noninvasively track the motion of a pulmonary lesion in real-time. The position of the lesion in the images is automatically determined by the image processing software and the motion of the robot is controlled to compensate for the lesion motion. The system was validated under CT fluoroscopy using a respiratory motion simulator. A swine study was also done to show the feasibility of the technique in a respiring animal.

  4. Core biopsy as a simple and effective diagnostic tool in head and neck focal myositis.

    PubMed

    Tan, Chun Yee; Chong, Sheldon; Shaw, Chi-Kee Leslie

    2015-12-01

    Most unilateral head and neck masses are benign, although malignancy is a possibility in some cases. However, there are other rare causes of unilateral neck masses, such as focal myositis, which is a rare, benign condition belonging to the family of inflammatory pseudotumors of the skeletal muscles, with rare presentations in the head and neck region. Focal myositis presents as a rapidly enlarging neck mass that can be misdiagnosed by fine-needle aspiration biopsy and/or radiologic imaging as either an infective or a neoplastic process. To date, there are only 5 reported cases of adult focal myositis of the sternocleidomastoid muscle in the medical literature. In this article, the authors present 2 cases involving patients with focal myositis of the sternocleidomastoid muscle that were successfully diagnosed with core-needle biopsy and managed conservatively. The pros and cons of fine-needle aspiration biopsy and core-needle biopsy are discussed. Based on the authors' results, fine-needle aspiration biopsy universally fails to provide the diagnosis of focal myositis. In contrast, core-needle biopsy successfully diagnosed focal myositis in both of our patients. Both of them had complete resolution with conservative management.

  5. Thoracic ultrasound-assisted selection for pleural biopsy with Abrams needle.

    PubMed

    Botana-Rial, Maribel; Leiro-Fernández, Virginia; Represas-Represas, Cristina; González-Piñeiro, Ana; Tilve-Gómez, Amara; Fernández-Villar, Alberto

    2013-11-01

    Closed pleural biopsy (CPB) in patients with malignant pleural effusion is less sensitive than cytology. Ultrasound-assisted CPB allows biopsies to be performed in the lower thoracic parietal pleura, where secondary spread from pleural metastases is initially more likely to be found. We analyzed whether choosing the point of entry for CPB with thoracic ultrasound assistance influences the diagnostic yield in malignant pleural effusion. This prospective study included patients who underwent CPB performed by an experienced pulmonologist in 2008-2010 (group A) and thoracic ultrasound was used to select the biopsy site. The results were compared with a historical series of CPB performed by the same pulmonologist without the assistance of thoracic ultrasound (group B). An Abrams needle was used in all cases. We analyzed the obtaining of pleural tissue and the diagnostic yield. We included 114 CPBs from group A (23% tuberculous pleural effusion, 27% malignant pleural effusion) and 67 CPBs from group B (24% tuberculous pleural effusion, 30% malignant pleural effusion) (P = .70). Pleural tissue was obtained in 96.5% of the group A CPBs and 89.6% of the group B CPBs (P = .05). The diagnostic yields of CPB for tuberculous pleural effusion and malignant pleural effusion in group A were 89.5% and 77.4%, respectively, and 91.7% and 60%, respectively, in group B (P = .80 for tuberculous pleural effusion, and P = .18 for malignant pleural effusion). Selecting the point of entry for CPB using thoracic ultrasound increases the likelihood of obtaining pleural tissue and the diagnostic yield, but without statistical significance. We recommend ultrasound-assisted CPB to investigate pleural effusion, since the diagnostic yield of a pleural biopsy with an Abrams needle increased by > 17% in subjects with malignant pleural effusion.

  6. Accessible or Inaccessible? Diagnostic Efficacy of CT-Guided Core Biopsies of Head and Neck Masses

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Cunningham, Jane D., E-mail: janecunningham0708@gmail.com; McCusker, Mark W.; Power, Sarah

    PurposeTissue sampling of lesions in the head and neck is challenging due to complex regional anatomy and sometimes necessitates open surgical biopsy. However, many patients are poor surgical candidates due to comorbidity. Thus, we evaluated the use of CT guidance for establishing histopathological diagnosis of head and neck masses.MethodsAll consecutive patients (n = 22) who underwent CT-guided core biopsy of head or neck masses between April 2009 and August 2012 were retrospectively reviewed using the departmental CT interventional procedures database. The indication for each biopsy performed was to establish or exclude a diagnosis of neoplasia in patients with suspicious head or neckmore » lesions found on clinical examination or imaging studies. Patients received conscious sedation and 18 G, semiautomated core needle biopsies were performed by experienced neuroradiologists using 16-slice multidetector row CT imaging guidance (Somatom Definition Siemens Medical Solutions, Germany). Histopathology results of each biopsy were analysed.ResultsSixteen of 22 biopsies that were performed (73 %) yielded a pathological diagnosis. Anatomic locations biopsied included: masticator (n = 7), parapharyngeal (n = 3), parotid (n = 3), carotid (n = 3), perivertebral (n = 3), pharyngeal (n = 2), and retropharyngeal (n = 1) spaces. Six biopsies (27 %) were nondiagnostic due to inadequate tissue sampling, particularly small biopsy sample size and failure to biopsy the true sampling site due to extensive necrosis. No major complications were encountered.ConclusionsThe use of CT guidance to perform core biopsies of head and neck masses is an effective means of establishing histopathological diagnosis and reduces the need for diagnostic open surgical biopsy and general anaesthesia.« less

  7. Vacuum-assisted closure therapy in the management of lung abscess.

    PubMed

    Sziklavari, Zsolt; Ried, Michael; Hofmann, Hans-Stefan

    2014-09-06

    Despite significant advances in the treatment of thoracic infections, complex lung abscess remains a problem in modern thoracic surgery. We describe the novel application of vacuum-assisted closure for the treatment of a lung abscess. The technical details and preliminary results are reported. After the initial failed conservative treatment of an abscess, minimally invasive surgical intervention was performed with vacuum-assisted closure. The vacuum sponges were inserted in the abscess cavity at the most proximal point to the pleural surface. The intercostal space of the chest wall above the entering place was secured by a soft tissue retractor. The level of suction was initially set to 100 mm Hg, with a maximum suction of 125 mm Hg. The sponge was changed once on the 3rd postoperative day. The abscess cavity was rapidly cleaned and decreased in size. The mini-thoracotomy could be closed on the 9th postoperative day. Closure of the cavity was simple, without any short- or long-term treatment failure. This technique reduced the trauma associated with the procedure. The patient was discharged on the 11th postoperative day. Vacuum-assisted closure systems should be considered for widespread use as an alternative option for the treatment of complicated pulmonary abscess in elderly, debilitated, immunocompromised patients after failed conservative treatment.

  8. Ultrasound-guided core needle biopsy in diagnosis of abdominal and pelvic neoplasm in pediatric patients.

    PubMed

    Wang, Hailing; Li, Fangxuan; Liu, Juntian; Zhang, Sheng

    2014-01-01

    Ultrasound-guided core needle biopsy of abdominal and pelvic masses in adults has gained tremendous popularity. However, the application of the same treatment in children is not as popular because of apprehensions regarding inadequate tissues for the biopsy and accidental puncture of vital organs. Data of the application of ultrasound-guided core needle biopsy in 105 pediatric patients with clinically or ultrasound-diagnosed abdominopelvic masses were reviewed. Diagnostic procedures were conducted in our institution from May 2011 to May 2013. The biopsies were conducted on 86 malignant lesions and 19 benign lesions. 86 malignant tumors comprised neuroblastomas (30 cases), hepatoblastomas (15 cases), nephroblastomas (11 cases), and primitive neuroectodermal tumors/malignant small round cells (6 cases). Among malignant tumor cases, only a pelvic primitive neuroectodermal tumor did not receive a pathological diagnosis. Therefore, the biopsy accuracy was 98.8 % in malignant tumor. However, the biopsies for one neuroblastomas and one malignant small round cell tumor were inadequate for cytogenetic analysis. Therefore, 96.5 % of the malignant tumor patients received complete diagnosis via biopsy. 19 benign tumors comprised mature teratoma (10 cases), hemangioendothelioma (3 cases), paraganglioma (2 cases), and infection (2 cases). The diagnostic accuracy for benign neoplasm was 100 %. Five patients experienced postoperative complications, including pain (2 patients), bleeding from the biopsy site (2 patients), and wound infection (1 patient). Ultrasound-guided core needle biopsy is an efficient, minimally invasive, accurate, and safe diagnostic method that can be applied in the management of abdominal or pelvic mass of pediatric patients.

  9. Confocal fluorescence microscopy for rapid evaluation of invasive tumor cellularity of inflammatory breast carcinoma core needle biopsies.

    PubMed

    Dobbs, Jessica; Krishnamurthy, Savitri; Kyrish, Matthew; Benveniste, Ana Paula; Yang, Wei; Richards-Kortum, Rebecca

    2015-01-01

    Tissue sampling is a problematic issue for inflammatory breast carcinoma, and immediate evaluation following core needle biopsy is needed to evaluate specimen adequacy. We sought to determine if confocal fluorescence microscopy provides sufficient resolution to evaluate specimen adequacy by comparing invasive tumor cellularity estimated from standard histologic images to invasive tumor cellularity estimated from confocal images of breast core needle biopsy specimens. Grayscale confocal fluorescence images of breast core needle biopsy specimens were acquired following proflavine application. A breast-dedicated pathologist evaluated invasive tumor cellularity in histologic images with hematoxylin and eosin staining and in grayscale and false-colored confocal images of cores. Agreement between cellularity estimates was quantified using a kappa coefficient. 23 cores from 23 patients with suspected inflammatory breast carcinoma were imaged. Confocal images were acquired in an average of less than 2 min per core. Invasive tumor cellularity estimated from histologic and grayscale confocal images showed moderate agreement by kappa coefficient: κ = 0.48 ± 0.09 (p < 0.001). Grayscale confocal images require less than 2 min for acquisition and allow for evaluation of invasive tumor cellularity in breast core needle biopsy specimens with moderate agreement to histologic images. We show that confocal fluorescence microscopy can be performed immediately following specimen acquisition and could indicate the need for additional biopsies at the initial visit.

  10. Concordance of DNA methylation profiles between breast core biopsy and surgical excision specimens containing ductal carcinoma in situ (DCIS).

    PubMed

    Chen, Youdinghuan; Marotti, Jonathan D; Jenson, Erik G; Onega, Tracy L; Johnson, Kevin C; Christensen, Brock C

    2017-08-01

    The utility and reliability of assessing molecular biomarkers for translational applications on pre-operative core biopsy specimens assume consistency of molecular profiles with larger surgical specimens. Whether DNA methylation in ductal carcinoma in situ (DCIS), measured in core biopsy and surgical specimens are similar, remains unclear. Here, we compared genome-scale DNA methylation measured in matched core biopsy and surgical specimens from DCIS, including specific DNA methylation biomarkers of subsequent invasive cancer. DNA was extracted from guided 2mm cores of formalin fixed paraffin embedded (FFPE) specimens, bisulfite-modified, and measured on the Illumina HumanMethylation450 BeadChip. DNA methylation profiles of core biopsies exhibited high concordance with matched surgical specimens. Within-subject variability in DNA methylation was significantly lower than between-subject variability (all P<2.20E-16). In 641 CpGs whose methylation was related with increased hazard of invasive breast cancer, lower within-subject than between-subject variability was observed in 92.3% of the study participants (P<0.05). Between patient-matched core biopsy and surgical specimens, <0.6% of CpGs measured had changes in median DNA methylation >15%, and a pathway analysis of these CpGs indicated enrichment for genes related with wound healing. Our results indicate that DNA methylation measured in core biopsies are representative of the matched surgical specimens and suggest that DCIS biomarkers measured in core biopsies can inform clinical decision-making. Copyright © 2017 The Authors. Published by Elsevier Inc. All rights reserved.

  11. Investigation of tissue cellularity at the tip of the core biopsy needle with optical coherence tomography.

    PubMed

    Iftimia, Nicusor; Park, Jesung; Maguluri, Gopi; Krishnamurthy, Savitri; McWatters, Amanda; Sabir, Sharjeel H

    2018-02-01

    We report the development and the pre-clinical testing of a new technology based on optical coherence tomography (OCT) for investigating tissue composition at the tip of the core biopsy needle. While ultrasound, computed tomography, and magnetic resonance imaging are routinely used to guide needle placement within a tumor, they still do not provide the resolution needed to investigate tissue cellularity (ratio between viable tumor and benign stroma) at the needle tip prior to taking a biopsy core. High resolution OCT imaging, however, can be used to investigate tissue morphology at the micron scale, and thus to determine if the biopsy core would likely have the expected composition. Therefore, we implemented this capability within a custom-made biopsy gun and evaluated its capability for a correct estimation of tumor tissue cellularity. A pilot study on a rabbit model of soft tissue cancer has shown the capability of this technique to provide correct evaluation of tumor tissue cellularity in over 85% of the cases. These initial results indicate the potential benefit of the OCT-based approach for improving the success of the core biopsy procedures.

  12. A Review of Inflammatory Processes of the Breast with a Focus on Diagnosis in Core Biopsy Samples

    PubMed Central

    D’Alfonso, Timothy M.; Ginter, Paula S.; Shin, Sandra J.

    2015-01-01

    Inflammatory and reactive lesions of the breast are relatively uncommon among benign breast lesions and can be the source of an abnormality on imaging. Such lesions can simulate a malignant process, based on both clinical and radiographic findings, and core biopsy is often performed to rule out malignancy. Furthermore, some inflammatory processes can mimic carcinoma or other malignancy microscopically, and vice versa. Diagnostic difficulty may arise due to the small and fragmented sample of a core biopsy. This review will focus on the pertinent clinical, radiographic, and histopathologic features of the more commonly encountered inflammatory lesions of the breast that can be characterized in a core biopsy sample. These include fat necrosis, mammary duct ectasia, granulomatous lobular mastitis, diabetic mastopathy, and abscess. The microscopic differential diagnoses for these lesions when seen in a core biopsy sample will be discussed. PMID:26095437

  13. A Review of Inflammatory Processes of the Breast with a Focus on Diagnosis in Core Biopsy Samples.

    PubMed

    D'Alfonso, Timothy M; Ginter, Paula S; Shin, Sandra J

    2015-07-01

    Inflammatory and reactive lesions of the breast are relatively uncommon among benign breast lesions and can be the source of an abnormality on imaging. Such lesions can simulate a malignant process, based on both clinical and radiographic findings, and core biopsy is often performed to rule out malignancy. Furthermore, some inflammatory processes can mimic carcinoma or other malignancy microscopically, and vice versa. Diagnostic difficulty may arise due to the small and fragmented sample of a core biopsy. This review will focus on the pertinent clinical, radiographic, and histopathologic features of the more commonly encountered inflammatory lesions of the breast that can be characterized in a core biopsy sample. These include fat necrosis, mammary duct ectasia, granulomatous lobular mastitis, diabetic mastopathy, and abscess. The microscopic differential diagnoses for these lesions when seen in a core biopsy sample will be discussed.

  14. Probability modeling of the number of positive cores in a prostate cancer biopsy session, with applications.

    PubMed

    Serfling, Robert; Ogola, Gerald

    2016-02-10

    Among men, prostate cancer (CaP) is the most common newly diagnosed cancer and the second leading cause of death from cancer. A major issue of very large scale is avoiding both over-treatment and under-treatment of CaP cases. The central challenge is deciding clinical significance or insignificance when the CaP biopsy results are positive but only marginally so. A related concern is deciding how to increase the number of biopsy cores for larger prostates. As a foundation for improved choice of number of cores and improved interpretation of biopsy results, we develop a probability model for the number of positive cores found in a biopsy, given the total number of cores, the volumes of the tumor nodules, and - very importantly - the prostate volume. Also, three applications are carried out: guidelines for the number of cores as a function of prostate volume, decision rules for insignificant versus significant CaP using number of positive cores, and, using prior distributions on total tumor size, Bayesian posterior probabilities for insignificant CaP and posterior median CaP. The model-based results have generality of application, take prostate volume into account, and provide attractive tradeoffs of specificity versus sensitivity. Copyright © 2015 John Wiley & Sons, Ltd. Copyright © 2015 John Wiley & Sons, Ltd.

  15. CT-guided transthoracic needle biopsy: a comparison between automated biopsy gun and fine needle aspiration.

    PubMed

    Arakawa, H; Nakajima, Y; Kurihara, Y; Niimi, H; Ishikawa, T

    1996-07-01

    We retrospectively investigated the diagnostic accuracy and complication rate of transthoracic core biopsy using an automated biopsy gun and compared the findings with those of aspiration needle biopsy. Seventy-three patients underwent 74 core biopsy procedures and 50 patients underwent 52 aspiration biopsy procedures. Of these, a final diagnosis was obtained in 107 lesions with surgery or clinical course. Fifteen patients in which a final diagnosis was not obtained were excluded from the study on diagnostic accuracy. Thus, in the study of diagnostic accuracy, 63 core biopsy procedures for 62 lesions are included. Core biopsy was performed with an 18 G cutting needle using an automated biopsy gun. Aspiration biopsy was performed with a 20 G aspiration needle. Core biopsy yielded sufficient material in 57/63 procedures (90.5%). A correct diagnosis was obtained in 36 procedures (85.7%) for malignant leisons and a specific benign diagnosis was obtained in 11 procedures (52.4%). Aspiration biopsy yielded a correct diagnosis in 26 procedures (81.3%) for malignant leisons and in seven (46.7%) for benign lesions. The overall correct diagnosis were 75.8% and 71.7% with core biopsy and aspiration biopsy, respectively. Core biopsy gave a higher predictive rate than that of aspiration biopsy for both benign and malignant lessons (P < 0.02). Pneumothorax occurred in 18/74 (24.3%) patients with core biopsy and in 18/45 (40.0%) patients with aspiration biopsy. Of these, three with core biopsy and two with aspiration biopsy needed tube drainage. The other complication was haemoptysis, which occurred in six patients following core biopsy and in three after aspiration biopsy. All nine cases subsided spontaneously. There were no fatal complications. Core biopsy with a biopsy gun increase the diagnostic accuracy with a higher histologic predictive rate and no obvious additional risk of complications.

  16. Recutting prostate needle core biopsies with high grade prostatic intraepithelial neoplasia increases detection of adenocarcinoma.

    PubMed

    Rapp, David E; Msezane, Lambda P; Reynolds, W Stuart; Lotan, Tamara L; Obara, Piotr; O'Connor, R Corey; Taxy, Jerome B; Gerber, Glenn S; Zagaja, Gregory P

    2009-02-01

    We sought to evaluate the ability of biopsy core recutting to increase cancer detection in patients with high grade prostatic intraepithelial neoplasia (HGPIN). This prospective study encompasses all patients undergoing 12 core TRUS guided prostate biopsy between February 2004 and January 2007. In patients with HGPIN on initial biopsy, the paraffin blocks were resampled for cancer by additional deeper levels per core. Additional analysis was performed in the patients with HGPIN in order to detect whether significant differences in prebiopsy variables were associated with patients subsequently found to have benign versus carcinoma on recutting. Last, the costs associated with this procedure were studied. Forty of 584 (6.8%) patients undergoing prostate biopsy were found to have HGPIN in the absence of prostatic adenocarcinoma on initial histopathology. Following recutting, 12.5% (5/40) of these patients were found to have prostatic adenocarcinoma not previously detected. Of the remaining 35 patients, 18 underwent repeat biopsy. Of these, five patients were found to have adenocarcinoma and three were found to have persistent HGPIN. The PSA, PSA density (PSAD), and PSA velocity (PSAV) prior to initial biopsy were not statistically different when comparing patients found to have benign tissue versus carcinoma on recutting. In patients with HGPIN, at our institution, recutting the biopsy would yield a cost savings of $436/patient as opposed to universal rebiopsy. Our data suggest that prostate biopsy recutting may increase cancer detection in patients initially found to have HGPIN. Additionally, a significant cost savings is associated with the recutting protocol.

  17. Comparison of the complications of traditional 12 cores transrectal prostate biopsy with image fusion guided transperineal prostate biopsy.

    PubMed

    Huang, Haifeng; Wang, Wei; Lin, Tingsheng; Zhang, Qing; Zhao, Xiaozhi; Lian, Huibo; Guo, Hongqian

    2016-11-17

    To compare the complications of traditional transrectal (TR) prostate biopsy and image fusion guided transperineal (TP) prostate biopsy in our center. Two hundred and fourty-two patients who underwent prostate biopsy from August 2014 to January 2015were reviewed. Among them, 144 patients underwent systematic 12-core transrectal ultrasonography (TRUS) guided prostate biopsy (TR approach) while 98 patients underwent free-hand transperineal targeted biopsy with TRUS and multi-parameter magnetic resonance imaging (mpMRI) fusion images (TP approach). The complications of the two groups were presented and a simple statistical analysis was performed to compare the two groups. The cohort of our study include242 patients, including 144 patients underwent TR biopsies while 98 patients underwentTP biopsies. There was no significant difference of major complications, including sepsis, bleeding and other complication requiring admissionbetween the two groups (P > 0.05). The incidence rate of infection and rectal bleeding in TR was much higher than TP (p < 0.05), but the incidence rate of perineal swelling in TP was much higher than TR (p < 0.05). There were no significant differences of minor complications including hematuria, lower urinary tract symptoms (LUTS), dysuria, and acuteurinary retention between the two groups (p > 0.05). The present study supports the safety of both techniques. Free-handTP targeted prostate biopsy with real-time fusion imaging of mpMRI and TR ultrasound is a good approach for prostate biopsy.

  18. Columnar cell change with atypia (flat epithelial atypia) on breast core biopsy-outcomes following open excision.

    PubMed

    Biggar, Magdalena A; Kerr, Kris M; Erzetich, Lisa M; Bennett, Ian C

    2012-01-01

    Columnar cell change with atypia (CCCA) is a relatively recently recognized pathologic breast entity considered to be a risk factor for subsequent development of breast carcinoma. The aim of this study was to investigate the significance of finding CCCA on breast core biopsy, by establishing the frequency of other breast pathology on subsequently performed surgical excision specimens. All cases with CCCA as the most advanced lesion on core biopsy were reviewed. After excision, another advanced proliferative lesion was identified in 17 (33%) patients, including three patients (6%) with in situ or invasive carcinoma. An additional five patients (10%) were concurrently diagnosed with primary breast carcinoma at other sites. These findings indicate that when CCCA is found on core biopsy, open surgical biopsy of the relevant area should be performed and that workup of both breasts should be undertaken to exclude coexistent breast carcinoma at alternative sites. © 2012 Wiley Periodicals, Inc.

  19. Risk factors for anal sphincter tears in vacuum-assisted delivery.

    PubMed

    Ryman, P; Ahlberg, M; Ekéus, C

    2015-10-01

    The aim of the present study was to describe the prevalence of anal sphincter tears (AST) in relation to obstetric management and technique during vacuum extraction deliveries (VE) (re: indications, the station of the fetal head at application of the cup, number of tractions, the length for the extraction, cup detachments, pain relief, episiotomy, fetal presentation, and experience of the operator) as well as maternal and infant anthropometrics. Descriptive study. Data on six hundred vacuum extraction deliveries were consecutively collected from six different delivery units in Sweden. Each unit contributed with data on 100 deliveries. The final study population included 596 women who delivered by vacuum extraction. There was no correlation between the management of the vacuum extraction and risk for anal sphincter tear. Women from Africa had nearly a fourfold risk for anal sphincter tear during vacuum-assisted delivery compared with Swedish-born women (OR 3.82 CI 1.47-9.89). Compared with infants with birth weight less than 4000 g, birth weight above 4000 g was associated with increased risk of AST (OR 1.87 CI 1.06-3.28). In this study, the obstetric management in VE-assisted deliveries did not impact the risk of AST. Copyright © 2015 Elsevier B.V. All rights reserved.

  20. Polymer film-nanoparticle composites as new multimodality, non-migrating breast biopsy markers.

    PubMed

    Kaplan, Jonah A; Grinstaff, Mark W; Bloch, B Nicolas

    2016-03-01

    To develop a breast biopsy marker that resists fast and slow migration and has permanent visibility under commonly used imaging modalities. A polymer-nanoparticle composite film was prepared by embedding superparamagnetic iron oxide nanoparticles and a superelastic Nitinol wire within a flexible polyethylene matrix. MRI, mammography, and ultrasound were used to visualize the marker in agar, ex vivo chicken breast, bovine liver, brisket, and biopsy training phantoms. Fast migration caused by the "accordion effect" was quantified after simulated stereotactic, vacuum-assisted core biopsy/marker placement, and centrifugation was used to simulate accelerated long-term (i.e., slow) migration in ex vivo bovine tissue phantoms. Clear marker visualization under MRI, mammography, and ultrasound was observed. After deployment, the marker partially unfolds to give a geometrically constrained structure preventing fast and slow migration. The marker can be deployed through an 11G introducer without fast migration occurring, and shows substantially less slow migration than conventional markers. The polymer-nanoparticle composite biopsy marker is clearly visible on all clinical imaging modalities and does not show substantial migration, which ensures multimodal assessment of the correct spatial information of the biopsy site, allowing for more accurate diagnosis and treatment planning and improved breast cancer patient care. Polymer-nanoparticle composite biopsy markers are visualized using ultrasound, MRI, and mammography. Embedded iron oxide nanoparticles provide tuneable contrast for MRI visualization. Permanent ultrasound visibility is achieved with a non-biodegradable polymer having a distinct ultrasound signal. Flexible polymer-based biopsy markers undergo shape change upon deployment to minimize migration. Non-migrating multimodal markers will help improve accuracy of pre/post-treatment planning studies.

  1. Accuracy assessment methods of tissue marker clip placement after 11-gauge vacuum-assisted stereotactic breast biopsy: comparison of measurements using direct and conventional methods.

    PubMed

    Yatake, Hidetoshi; Sawai, Yuka; Nishi, Toshio; Nakano, Yoshiaki; Nishimae, Ayaka; Katsuda, Toshizo; Yabunaka, Koichi; Takeda, Yoshihiro; Inaji, Hideo

    2017-07-01

    The objective of the study was to compare direct measurement with a conventional method for evaluation of clip placement in stereotactic vacuum-assisted breast biopsy (ST-VAB) and to evaluate the accuracy of clip placement using the direct method. Accuracy of clip placement was assessed by measuring the distance from a residual calcification of a targeted calcification clustered to a clip on a mammogram after ST-VAB. Distances in the craniocaudal (CC) and mediolateral oblique (MLO) views were measured in 28 subjects with mammograms recorded twice or more after ST-VAB. The difference in the distance between the first and second measurements was defined as the reproducibility and was compared with that from a conventional method using a mask system with overlap of transparent film on the mammogram. The 3D clip-to-calcification distance was measured using the direct method in 71 subjects. The reproducibility of the direct method was higher than that of the conventional method in CC and MLO views (P = 0.002, P < 0.001). The median 3D clip-to-calcification distance was 2.8 mm, with an interquartile range of 2.0-4.8 mm and a range of 1.1-36.3 mm. The direct method used in this study was more accurate than the conventional method, and gave a median 3D distance of 2.8 mm between the calcification and clip.

  2. Ultrasound-guided core biopsy in the diagnosis of lymphoma of the head and neck. A 9 year experience

    PubMed Central

    Burke, C; Thomas, R; Inglis, C; Baldwin, A; Ramesar, K; Grace, R; Howlett, D C

    2011-01-01

    Objectives This retrospective study aimed to evaluate the diagnostic utility of ultrasound-guided core biopsy (USCB) in lymphoma of the head and neck, in particular whether core biopsy can provide sufficient diagnostic information for definitive treatment. Methods All lymphomas diagnosed in the head and neck at Eastbourne General Hospital between January 2000 and June 2009 were identified. Radiology and pathology reports were reviewed and the diagnostic techniques recorded. The type of biopsy (fine needle aspiration, needle core, surgical excision biopsy) used to establish a diagnosis sufficient to allow treatment, i.e. the "index" diagnostic technique, was identified. Previous inconclusive or inadequate biopsies were noted. Pathology reports based on USCB were graded 0–3 according to diagnostic completeness and ability to provide treatment information. Results Of 691 overall cases of lymphoma diagnosed over the 9 year period, 171 different patients presented with lymphoma in the head and neck. Of these 171, 83 had USCB biopsy during diagnostic work up. 60 were regarded as grade 3 where a confident diagnosis of lymphoma was made. In seven patients, clinical management proceeded on the basis of a suggestive (grade 2) pathology report without surgical excision, and these were therefore also included as "index" biopsies. Overall therefore, 67/83 core biopsies (81%) provided adequate information to allow treatment. Surgical excision biopsy was the index modality in 104 cases. Conclusion In the majority of cases USCB is adequate for confident histopathological diagnosis avoiding the need for surgical excision biopsy in cases of suspected head and neck lymphoma. PMID:21427181

  3. Management of intraductal papilloma without atypia of the breast diagnosed on core biopsy: Size and sampling matter.

    PubMed

    Symbol, Brittany; Ricci, Andrew

    2018-04-23

    Due to the potential for atypia (atypical ductal or lobular hyperplasia) or carcinoma (in situ or invasive) on excision, aggressive reflex surgical excision protocols following core biopsy diagnosis of papillary lesions of the breast (ie, intraductal papilloma) are commonplace. Concepts in risk stratification, including radiologic-pathologic correlation, are emerging in an effort to curb unnecessary surgeries. To this end, we examined all excised intraductal papillomas diagnosed at our institution from 2010-2015 (N = 336) and found an overall atypia rate of 20%. To investigate further, we stratified all excised papillomas according to total lesion size (range = 1-40 mm) and found that the atypia rate for lesions ≤1.2 cm (16% with atypia) was statistically significantly lower (P = .008) than the atypia rate for lesions >1.2 cm (36% with atypia). To explore to effects of radiologic-pathologic correlation on the ability of the core biopsy to accurately predict nonatypical lesions we assessed thirteen consecutive paired nonatypical core biopsy/follow-up surgical excision specimens for the percent of the total lesion (on imaging) sampled by the core biopsy (measured histologically). None of the thirteen paired specimens showed upgrade on excision (0/13); the percent of total lesion sampled by biopsy in this cohort averaged 59%. We propose that in the absence of discordant clinical/radiological findings, small lesions (≤1.2 cm) with radiologic-pathologic concordance (>50% sampling of total lesion by core biopsy) may safely forego surgery for close clinical and radiographic follow-up. © 2018 Wiley Periodicals, Inc.

  4. Comparison of histologic diagnosis between stereotactic core needle biopsy and open surgical biopsy.

    PubMed

    Bauer, R L; Sung, J; Eckhert, K H; Koul, A; Castillo, N B; Nemoto, T

    1997-06-01

    This study correlates the histologic findings of stereotactic core needle biopsy (SCNB) with open surgical biopsy (OSB) and identifies which lesions can be treated definitively based only on the SCNB histology. Women who underwent SCNB between July 1, 1993, and January 1, 1969, were identified by retrospective chart review. Mammographic (MGM) lesions found by SCNB to be ductal or lobular hyperplasia with atypia, or carcinoma underwent OSB. When the histologic findings by SCNB were inconsistent with the MGM findings, the lesion also underwent OSB. 799 women underwent SCNB with 96 (12%) of these going on to OSB. MGM findings in the 92 who presented without a palpable mass included microcalcifications (MCS) in 39, mass in 47, MCS and mass in 7, and tissue distortion in 3. One hundred one breast lesions biopsied first by SCNB, then by OSB were correlated histologically. Sensitivity of SCNB is 89%, with a specificity of 94%. Eight-four women (88%) were able to have definitive treatment at time of OSB because of prior SCNB, and 703/799 (88%) of women were spared OSB entirely. SCNB accurately identifies benign breast histology and invasive cancers in women with MGM abnormalities, a distinct advantage over fine needle aspiration cytology. SCNB does not reliably identify women with DCIS and invasion. All women with SCNB diagnosis of ductal or lobular atypia should also undergo OSB.

  5. Vacuum Compatibility of Flux-Core Arc Welding (FCAW)

    NASA Astrophysics Data System (ADS)

    Arose, Dana; Denault, Martin; Jurcznski, Stephan

    2010-11-01

    Typically, vacuum chambers are welded together using gas tungsten arc welding (GTAW) or gas metal arc welding (GMAW). This is demonstrated in the vacuum chamber of Princeton Plasma Physics Lab's (PPPL) National Spherical Torus Experiment (NSTX). These processes are slow and apply excess heat to the base metal, which may cause the vacuum chamber to deform beyond designed tolerance. Flux cored arc welding (FCAW) avoids these problems, but may produce an unacceptable amount of outgasing due to the flux shielding. We believe impurities due to outgasing from FCAW will not greatly exceed those found in GTAW and GMAW welding. To test this theory, samples welded together using all three welding processes will be made and baked in a residual gas analyzer (RGA). The GTAW and GMAW welds will be tested to establish a metric for permissible outgasing. By testing samples from all three processes we hope to demonstrate that FCAW does not significantly outgas, and is therefore a viable alternative to GTAW and GMAW. Results from observations will be presented.

  6. MRI follow-up after concordant, histologically benign diagnosis of breast lesions sampled by MRI-guided biopsy.

    PubMed

    Li, Jie; Dershaw, D David; Lee, Carol H; Kaplan, Jennifer; Morris, Elizabeth A

    2009-09-01

    Follow-up MRI can be useful to confirm a benign diagnosis after MRI-guided breast biopsy. This retrospective study was undertaken to evaluate appropriate timing and imaging interpretation for the initial follow-up MRI when a benign, concordant histology is obtained using MRI-guided breast biopsy. Retrospective review was performed of 177 lesions visualized only by MRI in 172 women who underwent 9-gauge, vacuum-assisted core biopsy and marker placement with imaging-concordant benign histology. All underwent follow-up MRI within 12 months. Timing of the follow-up study, change in size, results of second biopsy if performed, and distance of localizing marker to the lesion on the follow-up study were recorded. At initial follow-up, 155 lesions were decreased or gone, 14 lesions were stable, and eight were enlarged. Seventeen (9.6%, 17/177) lesions underwent a second biopsy, including six enlarging, 10 stable, and one decreasing. Of these, four were malignant. Enlargement was seen in two carcinomas at 6 and 12 months. Two carcinomas, one stable at 2 months and another stable at 3 and 11 months, were rebiopsied because of suspicion of a missed lesion in the former and worrisome mammographic and sonographic changes in the latter. The distance of the marker from the lesion on follow-up did not correlate with biopsy accuracy. Follow-up MRI did not detect missed cancers because of lesion enlargement before 6 months after biopsy; two of four missed cancers were stable. The localizing marker can deploy away from the target despite successful sampling.

  7. Vacuum-assisted closure therapy increases local interleukin-8 and vascular endothelial growth factor levels in traumatic wounds.

    PubMed

    Labler, Ludwig; Rancan, Mario; Mica, Ladislav; Härter, Luc; Mihic-Probst, Daniela; Keel, Marius

    2009-03-01

    Clinical observations are suggesting accelerated granulation tissue formation in traumatic wounds treated with vacuum-assisted closure (VAC). Aim of this study was to determine the impact of VAC therapy versus alternative Epigard application on local inflammation and neovascularization in traumatic soft tissue wounds. Thirty-two patients with traumatic wounds requiring temporary coverage (VAC n = 16; Epigard n = 16) were included. At each change of dressing, samples of wound fluid and serum were collected (n = 80). The cytokines interleukin (IL)-6, IL-8, vascular endothelial growth factor (VEGF), and fibroblast growth factor-2 were measured by ELISA. Wound biopsies were examined histologically for inflammatory cells and degree of neovascularization present. All cytokines were found to be elevated in wound fluids during both VAC and Epigard treatment, whereas serum concentrations were negligible or not detectable. In wound fluids, significantly higher IL-8 (p < 0.001) and VEGF (p < 0.05) levels were detected during VAC therapy. Furthermore, histologic examination revealed increased neovascularization (p < 0.05) illustrated by CD31 and von Willebrand factor immunohistochemistry in wound biopsies of VAC treatment. In addition, there was an accumulation of neutrophils as well as an augmented expression of VEGF (p < 0.005) in VAC wound biopsies. This study suggests that VAC therapy of traumatic wounds leads to increased local IL-8 and VEGF concentrations, which may trigger accumulation of neutrophils and angiogenesis and thus, accelerate neovascularization.

  8. Modified Core Wash Cytology: A reliable same day biopsy result for breast clinics.

    PubMed

    Bulte, J P; Wauters, C A P; Duijm, L E M; de Wilt, J H W; Strobbe, L J A

    2016-12-01

    Fine Needle Aspiration Biopsy (FNAB), Core Needle biopsy (CNB) and hybrid techniques including Core Wash Cytology (CWC) are available for same-day diagnosis in breast lesions. In CWC a washing of the biopsy core is processed for a provisional cytological diagnosis, after which the core is processed like a regular CNB. This study focuses on the reliability of CWC in daily practice. All consecutive CWC procedures performed in a referral breast centre between May 2009 and May 2012 were reviewed, correlating CWC results with the CNB result, definitive diagnosis after surgical resection and/or follow-up. Symptomatic as well as screen-detected lesions, undergoing CNB were included. 1253 CWC procedures were performed. Definitive histology showed 849 (68%) malignant and 404 (32%) benign lesions. 80% of CWC procedures yielded a conclusive diagnosis: this percentage was higher amongst malignant lesions and lower for benign lesions: 89% and 62% respectively. Sensitivity and specificity of a conclusive CWC result were respectively 98.3% and 90.4%. The eventual incidence of malignancy in the cytological 'atypical' group (5%) was similar to the cytological 'benign' group (6%). CWC can be used to make a reliable provisional diagnosis of breast lesions within the hour. The high probability of conclusive results in malignant lesions makes CWC well suited for high risk populations. Copyright © 2016 Elsevier Ltd, BASO ~ the Association for Cancer Surgery, and the European Society of Surgical Oncology. All rights reserved.

  9. Assessment of "grading" with Ki-67 and c-kit immunohistochemical expressions may be a helpful tool in management of patients with flat epithelial atypia (FEA) and columnar cell lesions (CCLs) on core breast biopsy.

    PubMed

    Tomasino, Rosa M; Morello, Vincenza; Gullo, Arianna; Pompei, Giancarlo; Agnese, Valentina; Russo, Antonio; Rinaldi, Gaetana

    2009-11-01

    It is essential to reach a better understanding of "flat epithelial atypia/columnar cell lesions" (FEA/CCLs) in breast core biopsies. Our aim was to explore their biological nature, in order to predict the likelihood of an upgrade to carcinoma. "Cytological grading" has been specially focused, in view of its possible utility in the choice of management. One hundred thirty of a total of 900 cases core needle (CN)/vacuum-assisted biopsies (VABs), with diagnoses of "hyperplasia" and "atypia" were retrospectively re-evaluated. Pathological findings of further excision biopsies (FEBs) performed in 40/75 patients with follow-up were compared with the previous diagnoses. In all cases, both Ki-67 and c-kit immunoreactivities were explored and compared with both normal breast tissues and subsequently documented cancers, with special reference to the hyperplastic FEA/CCLs, with "mild" atypia (FEA/CCHAm). Sixteen cases were re-diagnosed as "usual ductal hyperplasia" (UDH), 60 as "columnar cell hyperplasia" (CCH), and 54 as FEA/CCHA, 30 of which FEA/CCHAm and 24 FEA/CCHAh (with high atypia). Significantly, the Ki-67 index proved to be on the increase and c-kit expression on the decrease in FEA/CCHA lesions, mainly in the FEA/CCHAh group and in the subsequently observed cancers, compared with either benign tissues or the FEA/CCH cases. It was also significant that most of the carcinomas were found in FEBs within the FEA/CCHAh group. In this study cytological grading, together with Ki-67 and c-kit indices, proved to be helpful in FEA/CCLs evaluation. With regard to FEA/CCHAm lesions, an adequate surveillance appears to be a more appropriate management tool than FEB, as a result of their biological nature and behavior.

  10. [Non-palpable breast cancer malignant on needle core biopsy and no malignancy in surgical excision: how to manage?].

    PubMed

    Cheurfa, N; Giard, S

    2015-01-01

    Despite the standard management of non-palpable breast cancer (needle core biopsy diagnostic, accurate preoperative localization), there are differences in some cases between the malignant histo-pathological finding in diagnostic biopsy results and negative histo-pathological finding after surgical excision. The aim of this study is to evaluate this incidence and classifying them under three category: failure of surgical excision after preoperative identification; removal of the tumor was already completed by percutaneous biopsy; percutaneous biopsy true false positive. We conducted a study based on prospective database, all patients included in this study had partial mastectomy for ductal carcinoma in-situ or invasive cancer which was diagnosed by needle core biopsy and normal/benign after surgery. Regarding the partial mastectomy, 1863 was performed in the last three years in our center. Thirty-seven patients (2%) correspond our study criteria. After discussion of cases in our multidisciplinary reunion, 6 patients (16%) were considered as failure of surgical excision, 26 patients (70%) as true removal of the whole lesion in the core, and 5 patients (13%) as true false-positive cores. This is the first study witch investigate all factors that influence the results of negative final histo-pathological finding of surgical excision of the tumor after malignant diagnostic needle core biopsy. This rare situation need a multidisciplinary meeting to analyse all the steps of management and to determine causes of those false results and try to find adequate management to solve this problem. Copyright © 2014 Elsevier Masson SAS. All rights reserved.

  11. 21. Engine identified as a 'single cylinder vacuum assist engine ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    21. Engine identified as a 'single cylinder vacuum assist engine for Tod tandem compound engine' showing compressor. - Carnegie Steel-Ohio Works, Steam Engines, 912 Salt Springs Road, Youngstown, Mahoning County, OH

  12. Randomized comparison of power Doppler ultrasonography-guided core-needle biopsy with open surgical biopsy for the characterization of lymphadenopathies in patients with suspected lymphoma.

    PubMed

    Pugliese, Novella; Di Perna, M; Cozzolino, I; Ciancia, G; Pettinato, G; Zeppa, P; Varone, V; Masone, S; Cerchione, C; Della Pepa, R; Simeone, L; Giordano, C; Martinelli, V; Salvatore, C; Pane, F; Picardi, M

    2017-04-01

    The sensitivity of lymph node core-needle biopsy under imaging guidance requires validation. We employed power Doppler ultrasonography (PDUS) to select the lymph node most suspected of malignancy and to histologically characterize it through the use of large cutting needle. Institutional review board approval and informed consent were obtained for this randomized clinical trial. In a single center between 1 January 2009 and 31 December 2015, patients with lymph node enlargement suspected for lymphoma were randomly assigned (1:1) to biopsy with either standard surgery or PDUS-guided 16-gauge modified Menghini needle. The primary endpoint was the superiority of sensitivity for the diagnosis of malignancy for core-needle cutting biopsy (CNCB). Secondary endpoints were times to biopsy, complications, and costs. A total of 376 patients were randomized into the two arms and received allocated biopsy. However, four patients undergoing CNCB were excluded for inadequate samples; thus, 372 patients were analyzed. Sensitivity for the detection of malignancy was significantly better for PDUS-guided CNCB [98.8%; 95% confidence interval (CI), 95.9-99.9] than standard biopsy (88.7%; 95% CI, 82.9-93; P < 0.001). For all secondary endpoints, the comparison was significantly disadvantageous for conventional approach. In particular, estimated cost per biopsy performed with standard surgery was 24-fold higher compared with that performed with CNCB. The presence of satellite enlarged reactive and/or necrotic lymph nodes may impair the success of an open surgical biopsy (OSB). PDUS and CNCB with adequate gauge are diagnostic tools that enable effective, safe, fast, and low-cost routine biopsy for patients with suspected lymphoma, avoiding psychological and physical pain of an unnecessary surgical intervention.

  13. Management of flat epithelial atypia on breast core biopsy may be individualized based on correlation with imaging studies.

    PubMed

    Calhoun, Benjamin C; Sobel, Amy; White, Richard L; Gromet, Matt; Flippo, Teresa; Sarantou, Terry; Livasy, Chad A

    2015-05-01

    Flat epithelial atypia of the breast commonly co-exists with atypical ductal hyperplasia, lobular neoplasia, and indolent forms of invasive carcinomas such as tubular carcinoma. Most patients with pure flat epithelial atypia on core biopsy undergo surgical excision to evaluate for carcinoma in the adjacent breast tissue. Studies to date have reported varying upgrade rates with most recommending follow-up excision. These studies have often lacked detailed radiographic correlation, central review by breast pathologists and information regarding the biology of the carcinomas identified upon excision. In this study, we report the frequency of upgrade to invasive carcinoma or ductal carcinoma in situ in excision specimens following a diagnosis of pure flat epithelial atypia on core biopsy. Radiographic correlation is performed for each case and grade/receptor status of detected carcinomas is reported. Seventy-three (73) core biopsies containing pure flat epithelial atypia were identified from our files, meeting inclusion criteria for the study. In the subsequent excision biopsies, five (7%) cases contained invasive carcinoma or ductal carcinoma in situ and seventeen (23%) contained atypical ductal hyperplasia or lobular neoplasia. All of the ductal carcinoma in situ cases with estrogen receptor results were estrogen receptor positive and intermediate grade. The invasive tumors were small (pT1a) hormone receptor-positive, HER2-negative, low-grade invasive ductal or tubular carcinomas with negative sentinel lymph-node biopsies. No upgrades were identified in the 14 patients who had all of their calcifications removed by the stereotactic core biopsy. Our rate of upgrade to carcinoma, once cases with discordant imaging are excluded, is at the lower end of the range reported in the literature. Given the low upgrade rate and indolent nature of the carcinomas associated with flat epithelial atypia, case management may be individualized based on clinical and radiographic

  14. Predicting response to primary chemotherapy: gene expression profiling of paraffin-embedded core biopsy tissue.

    PubMed

    Mina, Lida; Soule, Sharon E; Badve, Sunil; Baehner, Fredrick L; Baker, Joffre; Cronin, Maureen; Watson, Drew; Liu, Mei-Lan; Sledge, George W; Shak, Steve; Miller, Kathy D

    2007-06-01

    Primary chemotherapy provides an ideal opportunity to correlate gene expression with response to treatment. We used paraffin-embedded core biopsies from a completed phase II trial to identify genes that correlate with response to primary chemotherapy. Patients with newly diagnosed stage II or III breast cancer were treated with sequential doxorubicin 75 mg/M2 q2 wks x 3 and docetaxel 40 mg/M2 weekly x 6; treatment order was randomly assigned. Pretreatment core biopsy samples were interrogated for genes that might correlate with pathologic complete response (pCR). In addition to the individual genes, the correlation of the Oncotype DX Recurrence Score with pCR was examined. Of 70 patients enrolled in the parent trial, core biopsies samples with sufficient RNA for gene analyses were available from 45 patients; 9 (20%) had inflammatory breast cancer (IBC). Six (14%) patients achieved a pCR. Twenty-two of the 274 candidate genes assessed correlated with pCR (p < 0.05). Genes correlating with pCR could be grouped into three large clusters: angiogenesis-related genes, proliferation related genes, and invasion-related genes. Expression of estrogen receptor (ER)-related genes and Recurrence Score did not correlate with pCR. In an exploratory analysis we compared gene expression in IBC to non-inflammatory breast cancer; twenty-four (9%) of the genes were differentially expressed (p < 0.05), 5 were upregulated and 19 were downregulated in IBC. Gene expression analysis on core biopsy samples is feasible and identifies candidate genes that correlate with pCR to primary chemotherapy. Gene expression in IBC differs significantly from noninflammatory breast cancer.

  15. 20. Engine identified as a 'single cylinder vacuum assist engine ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    20. Engine identified as a 'single cylinder vacuum assist engine for the Tod tandem compound engine' showing crank end. - Carnegie Steel-Ohio Works, Steam Engines, 912 Salt Springs Road, Youngstown, Mahoning County, OH

  16. 19. Engine identified as a single cylinder vacuum assist engine ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    19. Engine identified as a single cylinder vacuum assist engine for the Filer and Stowell 15-inch continuous mill. - Carnegie Steel-Ohio Works, Steam Engines, 912 Salt Springs Road, Youngstown, Mahoning County, OH

  17. [Vacuum-assisted therapy for various wound types including diabetic foot ulcer].

    PubMed

    Farah, Raymond; Gantus, Maher; Kogan, Leonid

    2011-03-01

    Vacuum is a noninvasive system that creates a localized controlled negative pressure environment. In this study, vacuum was provided by the V.A.C. Therapy system, which promotes wound healing by delayed primary or secondary intention through creating a moist wound environment, preparing the wound bed for closure, reducing edema, and promoting formation and perfusion of granulation tissue. Vacuum-assisted closure therapy is indicated for use in all care settings and for a variety of wound types including diabetic foot ulcers. The purpose of this study was to evaluate safety and clinical efficacy of negative pressure wound therapy (NPWT) compared with advanced moist wound therapy and standard treatment to treat foot ulcers in diabetic patients. This trial enrolled 43 patients; most of them were diabetic patients at any age with various skin ulcers and diabetic foot. These patients were divided into two groups, 17 patients were treated with vacuum and the 26 patients in the control group were treated with standard therapy including debridement. A greater proportion of foot and skin ulcers achieved complete ulcer closure with vacuum-assisted therapy p<0.001 compared with the standard therapy. Vacuum therapy significantly decreased the duration and frequency of admission p=0.032 and decreased the rate of amputation p<0.001. Results of our trial support other studies and demonstrate that vacuum is as safe as and more efficacious than standard therapy in the treatment of diabetic foot ulcers. A significantly greater number of patients achieved complete ulcer closure and granulation tissue formation with this therapy. The study group showed a significant reduction in the median time needed to heal ulcers, reduction of the number of admissions and amputation frequency.

  18. Patient identification error among prostate needle core biopsy specimens--are we ready for a DNA time-out?

    PubMed

    Suba, Eric J; Pfeifer, John D; Raab, Stephen S

    2007-10-01

    Patient identification errors in surgical pathology often involve switches of prostate or breast needle core biopsy specimens among patients. We assessed strategies for decreasing the occurrence of these uncommon and yet potentially catastrophic events. Root cause analyses were performed following 3 cases of patient identification error involving prostate needle core biopsy specimens. Patient identification errors in surgical pathology result from slips and lapses of automatic human action that may occur at numerous steps during pre-laboratory, laboratory and post-laboratory work flow processes. Patient identification errors among prostate needle biopsies may be difficult to entirely prevent through the optimization of work flow processes. A DNA time-out, whereby DNA polymorphic microsatellite analysis is used to confirm patient identification before radiation therapy or radical surgery, may eliminate patient identification errors among needle biopsies.

  19. Surgical excision of pure flat epithelial atypia identified on core needle breast biopsy.

    PubMed

    Prowler, Vanessa L; Joh, Jennifer E; Acs, Geza; Kiluk, John V; Laronga, Christine; Khakpour, Nazanin; Lee, M Catherine

    2014-08-01

    The biology of flat epithelial atypia (FEA) is still being investigated as its presence becomes more frequent on biopsy specimens. FEA is more commonly associated with malignancy when found in association with ADH, ALH or LCIS. Pure FEA is only upgraded to cancer in 3.2% of patients. Surgical excision of pure FEA found on core needle biopsy results in overtreatment in the vast majority of breast patients and may not be necessary. Copyright © 2014 Elsevier Ltd. All rights reserved.

  20. Incidence of breast cancer in patients with pure flat epithelial atypia diagnosed at core-needle biopsy of the breast.

    PubMed

    Khoumais, Nuha A; Scaranelo, Anabel M; Moshonov, Hadas; Kulkarni, Supriya R; Miller, Naomi; McCready, David R; Youngson, Bruce J; Crystal, Pavel; Done, Susan J

    2013-01-01

    to determine the frequency of malignancy in subsequent breast excisions following core-needle biopsy (CNB) diagnosis of pure flat epithelial atypia (pFEA) and to evaluate the imaging features of the associated tumors. Retrospective review of 8,996 image-guided CNB (2002-2010) identified 115 cases of FEA not associated with other atypia. Patients with history of breast cancer or radiation therapy were excluded. One hundred four cases (women) with pFEA (mean age 51 years, range 29-77 years) were reviewed. Stereotactic CNB was performed in 79 (76%) cases and ultrasound (US)-guided CNB in 25 (24%) cases. In 99 cases 14G needles were used, and 10G vacuum-assisted devices were used in 5 cases. Ninety-four patients had subsequent excision. Ten patients declined excision, and imaging follow-up (mean of 36 months) is available. The upgrade rate of pFEA was defined as the number of patients diagnosed with invasive carcinoma (IC) or carcinoma in situ (CIS) divided by the total number of patients. 10 of 104 (9.6%) patients were diagnosed with cancer: 9 presented as calcifications (89% fine pleomorphic and amorphous) and 1 case as a mammographically occult mass. The size of calcifications was not statistically significant (P=0.358). Five cases had ductal carcinoma in situ (DCIS) and five cases had IC (ductal and lobular) presenting as amorphous and pleomorphic calcifications. The upgrade rate of pFEA in our series was 9.6%. The presence of 4.8% of invasive cancers is substantial and warrants continuing management with surgical excision in all cases.

  1. Comparison of EUS-guided tissue acquisition using two different 19-gauge core biopsy needles: a multicenter, prospective, randomized, and blinded study

    PubMed Central

    DeWitt, John; Cho, Chang-Min; Lin, Jingmei; Al-Haddad, Mohammad; Canto, Marcia Irene; Salamone, Ashley; Hruban, Ralph H.; Messallam, Ahmed A.; Khashab, Mouen A.

    2015-01-01

    Background and study aims: The optimal core biopsy needle for endoscopic ultrasound (EUS) is unknown. The principle aim of this study is to compare outcomes of EUS-fine-needle biopsy (EUS-FNB) with a new 19-gauge EUS histology needle (ProCore, Cook Medical Inc., Winston-Salem, North Carolina, United States) to a conventional 19-gauge Tru-Cut biopsy (EUS-TCB) needle (19G, Quick-Core, Cook Medical Inc.). Patients and methods: Patients referred for EUS who require possible histologic biopsy were prospectively randomized to EUS-FNB or EUS-TCB. With the initial needle, ≤ 3 biopsies were obtained until either technical failure or an adequate core was obtained. Patients with suspected inadequate biopsies were crossed over to the other needle and similarly ≤ 3 passes were obtained until adequate cores or technical failure occurred. Technical success, diagnostic histology, accuracy and complication rates were evaluated. Results: Eighty-five patients (mean 58 years; 43 male) were randomized to FNB (n = 44) and TCB (n = 41) with seven patients excluded. Procedure indication, biopsy site, mass size, number of passes, puncture site, overall technical success and adverse events were similar between the two groups. FNB specimens had a higher prevalence of diagnostic histology (85 % vs. 57 %; P = 0.006), accuracy (88 % vs. 62 %; P = 0.02), mean total length (19.4 vs. 4.3 mm; P = 0.001), mean complete portal triads from liver biopsies (10.4 vs. 1.3; P = 0.0004) and required fewer crossover biopsies compared to those of TCB (2 % vs. 65 %; P = 0.0001). Overall technical success and complication rates were comparable. Conclusion: EUS-FNB using a 19-gauge FNB needle is superior to 19-gauge EUS-TCB needle. PMID:26528504

  2. Accuracy and effectiveness of ultrasound-guided core-needle biopsy in the diagnosis of focal lesions in the salivary glands.

    PubMed

    Del Cura, Jose Luis; Coronado, Gloria; Zabala, Rosa; Korta, Igone; López, Ignacio

    2018-01-31

    To review the diagnostic accuracy of ultrasound-guided core-needle biopsy (CNB) in the diagnosis of salivary gland tumours (SGT). Retrospective, institutional review board approved, analysis of the CNB of SGT performed at our centre in 8 years. We used an automatic 18-G spring-loaded device. The final diagnosis was based on surgery in the cases that were operated on, and on clinical evolution and biopsy findings in the rest. Four hundred and nine biopsies were performed in 381 patients (ages, 2-97 years; mean, 55.9). There were two minor complications. Biopsy was diagnostic in 98.3%. There were eight false negatives. The diagnostic values for malignancy were: sensitivity 89.6%, specificity 100%, positive predictive value (PPV) 100% and negative predictive value (NPV) 98%. For the detection of neoplasms were: sensitivity 98.7%, specificity 99%, PPV 99.7% and VPN 96.1%. Accuracy of CNB in SGT is very high, with a very high sensitivity and an absolutely reliable diagnosis of malignancy. Complication rate is very low. It should be considered the technique of choice when a STG is detected. Normal tissue results warrant repeating biopsy. • Ultrasound-guided core-biopsy is the technique of choice in salivary glands nodules • Sensitivity, specificity for detecting neoplasms (which should be resected) are around 99% • Diagnosis of malignancy in core-biopsy is absolutely reliable • A CNB result of "normal tissue", however, warrants repeating the biopsy • Complication rate is very low.

  3. Non-malignant breast papillary lesions - b3 diagnosed on ultrasound--guided 14-gauge needle core biopsy: analysis of 114 cases from a single institution and review of the literature.

    PubMed

    Bianchi, Simonetta; Bendinelli, Benedetta; Saladino, Valeria; Vezzosi, Vania; Brancato, Beniamino; Nori, Jacopo; Palli, Domenico

    2015-07-01

    One-hundred-fourteen consecutive cases of breast ultrasound-guided 14-gauge needle core biopsy (14G NCB) performed from January 2001 to June 2013 and diagnosed as non-malignant papillary lesion (PL)-B3, were reviewed and compared with definitive histological diagnosis on surgical excision (SE) to evaluate the diagnostic accuracy of ultrasound-guided 14G NCB. PL with epithelial atypia on 14G NCB were associated to malignancy on definitive histological diagnosis on SE in 22 (7 DCIS and 15 invasive carcinomas) of 46 cases with an underestimation rate of 47.8 %, while 9 (4 DCIS and 5 invasive carcinomas) cases out of 68 cases of PL without epithelial atypia were upgraded to carcinoma with an underestimation rate of 13.2 %. In cases of PL with epithelial atypia on ultrasound-guided 14G NCB, SE appears mandatory due to the high risk of associated malignancy. The diagnosis of PL without epithelial atypia on ultrasound-guided 14G NCB does not exclude malignancy at subsequent SE, consequently further assessment (by surgical or vacuum-assisted excision) is recommended to avoid the risk of delaying a diagnosis of malignancy, although this tends to be lower (1 in 8 patients).

  4. Evaluation of a Prototype Hybrid Vacuum Pump to Provide Vacuum-Assisted Suspension for Above-Knee Prostheses

    PubMed Central

    Major, Matthew J.; Caldwell, Ryan; Fatone, Stefania

    2015-01-01

    Vacuum-assisted suspension (VAS) of prosthetic sockets utilizes a pump to evacuate air from between the prosthetic liner and socket, and are available as mechanical or electric systems. This technical note describes a hybrid pump that benefits from the advantages of mechanical and electric systems, and evaluates a prototype as proof-of-concept. Cyclical bench testing of the hybrid pump mechanical system was performed using a materials testing system to assess the relationship between compression cycles and vacuum pressure. Phase 1 in vivo testing of the hybrid pump was performed by an able-bodied individual using prosthesis simulator boots walking on a treadmill, and phase 2 involved an above-knee prosthesis user walking with the hybrid pump and a commercial electric pump for comparison. Bench testing of 300 compression cycles produced a maximum vacuum of 24 in-Hg. In vivo testing demonstrated that the hybrid pump continued to pull vacuum during walking, and as opposed to the commercial electric pump, did not require reactivation of the electric system during phase 2 testing. The novelty of the hybrid pump is that while the electric system provides rapid, initial vacuum suspension, the mechanical system provides continuous air evacuation while walking to maintain suspension without reactivation of the electric system, thereby allowing battery power to be reserved for monitoring vacuum levels. PMID:27462383

  5. Does therapeutic touch ease the discomfort or distress of patients undergoing stereotactic core breast biopsy? A randomized clinical trial.

    PubMed

    Frank, Leslie Smith; Frank, James L; March, David; Makari-Judson, Grace; Barham, Ruth B; Mertens, Wilson C

    2007-01-01

    To determine whether therapeutic touch administered at the time of stereotactic core biopsy of suspicious breast lesions results in a reduction in anxiety and pain. Randomized, patient-blinded, controlled trial of either Krieger-Kunz therapeutic touch administered by a trained practitioner or a sham intervention mimicking therapeutic touch delivered during core biopsy. Stereotactic breast biopsy unit of a comprehensive breast center. Women with mammographically detected, nonpalpable breast lesions requiring biopsy. Changes in pain and anxiety measured by visual analog scales immediately before and after stereotactic core biopsy. A total of 82 patients were accrued: 42 received actual therapeutic touch and 40 sham therapeutic touch. No significant differences were found between the arms for age, ethnicity, educational background, or other demographic data. The sham arm had a preponderance of left breast biopsies (48% vs 58%; P = 0.07) and received a slightly higher volume of epinephrine-containing local anesthetic (6.5 +/- 6.1 vs 4.5 +/- 4.5 mL; P = 0.09). Therapeutic touch patients were more likely to have an upper breast lesion location (57% vs 53%; P = 0.022). No significant differences between the arms were seen regarding postbiopsy pain (P = 0.95), anxiety (P = 0.66), fearfulness, or physiological parameters. Similarly, no differences were seen between the arms when change in parameters from prebiopsy to postbiopsy was considered for any of the psychological or physiological variables measured. These findings persisted when confounding variables were controlled for. Women undergoing stereotactic core breast biopsy received no significant benefit from therapeutic touch administered during the procedure. Therapeutic touch cannot be routinely recommended for patients in this setting.

  6. Diagnostic Yield of Computed Tomography-Guided Coaxial Core Biopsy of Undetermined Masses in the Free Retroperitoneal Space: Single-Center Experience

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Stattaus, Joerg, E-mail: joerg.stattaus@uni-due.de; Kalkmann, Janine, E-mail: janine.kalkmann@uk-essen.de; Kuehl, Hilmar, E-mail: hilmar.kuehl@uni-due.d

    2008-09-15

    The purpose of this study was to evaluate the diagnostic yield of core biopsy in coaxial technique under guidance of computed tomography (CT) for retroperitoneal masses. We performed a retrospective analysis of CT-guided coaxial core biopsies of undetermined masses in the non-organ-bound retroperitoneal space in 49 patients. In 37 cases a 15-G guidance needle with a 16-G semiautomated core biopsy system, and in 12 cases a 16-G guidance needle with an 18-G biopsy system, was used. All biopsies were technically successful. A small hematoma was seen in one case, but no relevant complication occurred. With the coaxial technique, up tomore » 4 specimens were obtained from each lesion (mean, 2.8). Diagnostic accuracy in differentiation between malignant and benign diseases was 95.9%. A specific histological diagnosis could be established in 39 of 42 malignant lesions (92.9%). Correct subtyping of malignant lymphoma according to the WHO classification was possible in 87.0%. Benign lesions were correctly identified in seven cases, although a specific diagnosis could only be made in conjunction with clinical and radiological information. In conclusion, CT-guided coaxial core biopsy provides safe and accurate diagnosis of retroperitoneal masses. A specific histological diagnosis, which is essential for choosing the appropriate therapy, could be established in most cases of malignancy.« less

  7. Immediate surgical resection of residual microcalcifications after a diagnosis of pure flat epithelial atypia on core biopsy: a word of caution.

    PubMed

    Noël, Jean-Christophe; Buxant, Frédéric; Engohan-Aloghe, Corinne

    2010-12-01

    The entity of pure flat epithelial atypia remains a challenge due to controversy of the surgical management of residual microcalcifications after core needle biopsies. This study aims to assess the morphological data observed in immediate surgical resection specimen of residual microcalcifications after a diagnosis of pure flat epithelial atypia on mammotome core biopsy. Sixty-two mammotome core biopsy with a diagnosis of pure flat epithelial atypia (flat epithelial atypia without associated atypical ductal hyperplasia, in situ and/or invasive carcinoma) were identified. From these 62 cases, 20 presented residual microcalcifications and underwent an immediate surgical excision after mammotome. Of the 20 patients with excised microcalcifications, 8 (40%)cases had residual pure flat epithelial atypia, 4 (20%) cases had atypical ductal hyperplasia, 4 (20%) cases had lobular in situ neoplasia, no lesions were retrieved in 4 (20%) case. None of the patients had either in situ ductal carcinoma and/or invasive carcinoma. Surgical resection of residual microcalcifications after the diagnosis of pure flat epithelial atypia on core needle biopsy remains still a debate. The present study shows no cases of in situ ductal and/or invasive carcinoma on immediate excision of residual microcalcifications after mammotome core biopsies. Copyright © 2009 Elsevier Ltd. All rights reserved.

  8. Flat epithelial atypia on core needle biopsy, must we surgically excise?

    PubMed

    Acott, A A; Mancino, A T

    2016-12-01

    Breast flat epithelial atypia (FEA) often coexists with more aggressive pathology and excision is currently recommended when diagnosed by core needle biopsy (CNB). Recent studies suggest isolated FEA has a low association with carcinoma and may warrant close surveillance. A radiology database containing 2189 breast CNB was reviewed for isolated FEA or FEA in combination with atypical pathology. 79 patients had FEA. There were 48/79 with isolated FEA and 31/79 concomitant FEA with ADH, ALH, or LCIS. 46 subsequent excisional biopsies of isolated FEA resulted: benign 38/46, ADH 5/46, LCIS 2/46, DCIS 1/46. Concomitant FEA + ADH/ALH/LCIS group resulted: benign 26/31, DCIS 3/31, DCIS and LCIS 1/31, tubular carcinoma 1/31. DCIS/invasive cancer on excision in the FEA + ADH group is 5/31 versus 1/46 for isolated FEA (p 0.0489). Findings support literature suggesting isolated FEA has a low association with carcinoma. These patients may not require surgical excision, but instead have close surveillance. Based on the higher cancer incidence in FEA combined with ADH, ALH, LCIS, or residual microcalcifications, we still recommend surgical excision. Breast flat epithelial atypia (FEA) often coexists with more aggressive pathology and surgical excision is currently recommended when diagnosed by core needle biopsy. Recent studies have suggested isolated FEA has a low association with carcinoma and these patients may warrant close surveillance. Isolated FEA has a low association with carcinoma in our series. These patients may not require surgical excision, but instead have close surveillance. Published by Elsevier Inc.

  9. Endoscopic ultrasound-guided fine-needle aspiration with on-site cytopathology versus core biopsy: a comparison of both techniques performed at the same endoscopic session

    PubMed Central

    Lin, Michael; Hair, Clark D.; Green, Linda K.; Vela, Stacie A.; Patel, Kalpesh K.; Qureshi, Waqar A.; Shaib, Yasser H.

    2014-01-01

    Background: Endoscopic ultrasound (EUS)-guided fine needle aspiration (FNA) with bedside cytopathology is the gold standard for assessment of pancreatic, subepithelial, and other lesions in close proximity to the gastrointestinal tract, but it is time-consuming, has certain diagnostic limitations, and bedside cytopathology is not widely available. Aims: The goal of this study is to compare the diagnostic yield of EUS-guided FNA with on-site cytopathology and EUS-guided core biopsy. Methods: Twenty-six patients with gastrointestinal mass lesions requiring biopsy at a tertiary medical center were included in this retrospective analysis of a prospective cohort. Two core biopsies were taken using a 22 gauge needle followed by FNA guided by a bedside cytopathologist at the same endoscopic session. The diagnostic yield and test characteristics of EUS core biopsy and EUS FNA with bedside cytopathology were examined. Results: The mean number of passes was 3.2 for FNA, and the mean procedure time was 39.4 minutes. The final diagnosis was malignant in 92.3 %. Sensitivity and specificity were 83 % and 100 %, respectively, for FNA, and 91.7 % and 100 %, respectively, for core biopsy. Diagnostic accuracy was 92.3 % for FNA and 84.6 % for core biopsy. The two approaches were in agreement in 88.4 % with a kappa statistic of 0.66 (95 % confidence interval 0.33 – 0.99). Conclusions: An approach using two passes with a core biopsy needle is comparable to the current gold standard of FNA with bedside cytopathology. The performance of two core biopsies is time-efficient and could represent a good alternative to FNA with bedside cytopathology. PMID:26135096

  10. EBUS-Guided Cautery-Assisted Transbronchial Forceps Biopsies: Safety and Sensitivity Relative to Transbronchial Needle Aspiration

    PubMed Central

    Bramley, Kyle; Pisani, Margaret A.; Murphy, Terrence E.; Araujo, Katy; Homer, Robert; Puchalski, Jonathan

    2016-01-01

    Background EBUS-guided transbronchial needle aspiration (TBNA) is important in the evaluation of thoracic lymphadenopathy. Reliably providing excellent diagnostic yield for malignancy, its diagnosis of sarcoidosis is inconsistent. Furthermore, when larger “core” biopsy samples of malignant tissue are required, TBNA may not suffice. The primary objective of this study was to determine if the sequential use of TBNA and a novel technique called cautery-assisted transbronchial forceps biopsies (ca-TBFB) was safe. Secondary outcomes included sensitivity and successful acquisition of tissue. Methods Fifty unselected patients undergoing convex probe EBUS were prospectively enrolled. Under EBUS guidance, all lymph nodes ≥ 1 cm were sequentially biopsied using TBNA and ca-TBFB. Safety and sensitivity were assessed at the nodal level for 111 nodes. Results of each technique were also reported on a per-patient basis. Results There were no significant adverse events. In nodes determined to be malignant, TBNA provided higher sensitivity (100%) than ca-TBFB (78%). However, among nodes with granulomatous inflammation, ca-TBFB exhibited higher sensitivity (90%) than TBNA (33%). For analysis based on patients rather than nodes, 6 of the 31 patients with malignancy would have been missed or understaged if the diagnosis was based on samples obtained by ca-TBFB. On the other hand, 3 of 8 patients with sarcoidosis would have been missed if analysis was based only on TBNA samples. In some cases only ca-TBFB acquired sufficient tissue for the core samples needed in clinical trials of malignancy. Conclusions The sequential use of TBNA and ca-TBFB appears to be safe. The larger samples obtained from ca-TBFB increased its sensitivity to detect granulomatous disease and provided specimens for clinical trials of malignancy when needle biopsies were insufficient. For thoracic surgeons and advanced bronchoscopists, we advocate ca-TBFB as an alternative to TBNA in select clinical scenarios

  11. Comparison of fine-needle aspiration and core needle biopsy under ultrasonographic guidance for detecting malignancy and for the tissue-specific diagnosis of salivary gland tumors.

    PubMed

    Eom, H-J; Lee, J H; Ko, M-S; Choi, Y J; Yoon, R G; Cho, K J; Nam, S Y; Baek, J H

    2015-06-01

    Diagnostic test accuracy studies for ultrasonography-guided fine-needle aspiration and ultrasonography-guided core needle biopsy have shown inconclusive results due to their heterogenous study designs. Our aim was to compare the diagnostic accuracy of ultrasonography-guided fine-needle aspiration versus ultrasonography-guided core needle biopsy for detecting malignant tumors of the salivary gland and for the tissue-specific diagnosis of salivary gland tumors in a single tertiary hospital. This retrospective study was approved by our institutional review board and informed consent was waived. Four hundred twelve patients who underwent ultrasonography-guided fine-needle aspiration (n = 155) or ultrasonography-guided core needle biopsy (n = 257) with subsequent surgical confirmation or clinical follow-up were enrolled. We compared the diagnostic accuracy of ultrasonography-guided fine-needle aspiration and ultrasonography-guided core needle biopsy regarding malignant salivary gland tumors and the correct tissue-specific diagnosis of benign and malignant tumors. We also tested the difference between these procedures according to the operator's experience and lesion characteristics. The inconclusive rates of ultrasonography-guided fine-needle aspiration and ultrasonography-guided core needle biopsy were 19% and 4%, respectively (P < .001). The overall accuracy of ultrasonography-guided core needle biopsy for diagnosing malignant tumors was significantly higher than that of ultrasonography-guided fine-needle aspiration (P = .024). The correct tissue-specific diagnosis rates of ultrasonography-guided fine-needle aspiration and ultrasonography-guided core needle biopsy were 95% versus 97% for benign tumors (P = .648) and 67% versus 80% for malignant tumors (P = .310). Trainees showed significantly lower accuracy with ultrasonography-guided fine-needle aspiration than with ultrasonography-guided core needle biopsy for diagnosing malignant tumors (P = .021). There was no

  12. Endobronchial Ultrasound-Guided Cautery-Assisted Transbronchial Forceps Biopsies: Safety and Sensitivity Relative to Transbronchial Needle Aspiration.

    PubMed

    Bramley, Kyle; Pisani, Margaret A; Murphy, Terrence E; Araujo, Katy L; Homer, Robert J; Puchalski, Jonathan T

    2016-05-01

    Endobronchial ultrasound (EBUS)-guided transbronchial needle aspiration (TBNA) is important in the evaluation of thoracic lymphadenopathy. Reliably providing excellent diagnostic yield for malignancy, its diagnosis of sarcoidosis is inconsistent. Furthermore, TBNA may not suffice when larger "core biopsy" samples of malignant tissue are required. The primary objective of this study was to determine if the sequential use of TBNA and a novel technique called cautery-assisted transbronchial forceps biopsy (ca-TBFB) was safe. Secondary outcomes included sensitivity and successful acquisition of tissue. The study prospectively enrolled 50 unselected patients undergoing convex-probe EBUS. All lymph nodes exceeding 1 cm were sequentially biopsied under EBUS guidance using TBNA and ca-TBFB. Safety and sensitivity were assessed at the nodal level for 111 nodes. Results of each technique were also reported for each patient. There were no significant adverse events. In nodes determined to be malignant, TBNA provided higher sensitivity (100%) than ca-TBFB (78%). However, among nodes with granulomatous inflammation, ca-TBFB exhibited higher sensitivity (90%) than TBNA (33%). On the one hand, for analysis based on patients rather than nodes, 6 of the 31 patients with malignancy would have been missed or understaged if the diagnosis were based on samples obtained by ca-TBFB. On the other hand, 3 of 8 patients with sarcoidosis would have been missed if analysis were based only on TBNA samples. In some patients, only ca-TBFB acquired sufficient tissue for the core samples needed in clinical trials of malignancy. The sequential use of TBNA and ca-TBFB appears to be safe. The larger samples obtained from ca-TBFB increased its sensitivity to detect granulomatous disease and provided adequate specimens for clinical trials of malignancy when specimens from needle biopsies were insufficient. For thoracic surgeons and advanced bronchoscopists, we advocate ca-TBFB as an alternative to TBNA

  13. Image guided versus palpation guided core needle biopsy of palpable breast masses: a prospective study

    PubMed Central

    Hari, Smriti; Kumari, Swati; Srivastava, Anurag; Thulkar, Sanjay; Mathur, Sandeep; Veedu, Prasad Thotton

    2016-01-01

    Background & objectives: Biopsy of palpable breast masses can be performed manually by palpation guidance or under imaging guidance. Based on retrospective studies, image guided biopsy is considered more accurate than palpation guided breast biopsy; however, these techniques have not been compared prospectively. We conducted this prospective study to verify the superiority and determine the size of beneficial effect of image guided biopsy over palpation guided biopsy. Methods: Over a period of 18 months, 36 patients each with palpable breast masses were randomized into palpation guided and image guided breast biopsy arms. Ultrasound was used for image guidance in 33 patients and mammographic (stereotactic) guidance in three patients. All biopsies were performed using 14 gauge automated core biopsy needles. Inconclusive, suspicious or imaging-histologic discordant biopsies were repeated. Results: Malignancy was found in 30 of 36 women in palpation guided biopsy arm and 27 of 36 women in image guided biopsy arm. Palpation guided biopsy had sensitivity, specificity, positive predictive value (PPV) and negative predictive value (NPV) of 46.7, 100, 100, 27.3 per cent, respectively, for diagnosing breast cancer. Nineteen of 36 women (52.8%) required repeat biopsy because of inadequate samples (7 of 19), suspicious findings (2 of 19) or imaging-histologic discordance (10 of 19). On repeat biopsy, malignancy was found in all cases of imaging-histologic discordance. Image guided biopsy had 96.3 per cent sensitivity and 100 per cent specificity. There was no case of inadequate sample or imaging-histologic discordance with image guided biopsy. Interpretation & conclusions: Our results showed that in palpable breast masses, image guided biopsy was superior to palpation guided biopsy in terms of sensitivity, false negative rate and repeat biopsy rates. PMID:27488003

  14. A low cost solution for post-biopsy complications using available RFA generator and coaxial core biopsy needle.

    PubMed

    Azlan, C A; Mohd Nasir, N F; Saifizul, A A; Faizul, M S; Ng, K H; Abdullah, B J J

    2007-12-01

    Percutaneous image-guided needle biopsy is typically performed in highly vascular organs or in tumours with rich macroscopic and microscopic blood supply. The main risks related to this procedure are haemorrhage and implantation of tumour cells in the needle tract after the biopsy needle is withdrawn. From numerous conducted studies, it was found that heating the needle tract using alternating current in radiofrequency (RF) range has a potential to minimize these effects. However, this solution requires the use of specially designed needles, which would make the procedure relatively expensive and complicated. Thus, we propose a simple solution by using readily available coaxial core biopsy needles connected to a radiofrequency ablation (RFA) generator. In order to do so, we have designed and developed an adapter to interface between these two devices. For evaluation purpose, we used a bovine liver as a sample tissue. The experimental procedure was done to study the effect of different parameter settings on the size of coagulation necrosis caused by the RF current heating on the subject. The delivery of the RF energy was varied by changing the values for delivered power, power delivery duration, and insertion depth. The results showed that the size of the coagulation necrosis is affected by all of the parameters tested. In general, the size of the region is enlarged with higher delivery of RF power, longer duration of power delivery, and shallower needle insertion and become relatively constant after a certain value. We also found that the solution proposed provides a low cost and practical way to minimizes unwanted post-biopsy effects.

  15. Histologic Findings of Severe/Therapy-Resistant Asthma From Video-assisted Thoracoscopic Surgery Biopsies.

    PubMed

    Trejo Bittar, Humberto E; Doberer, Daniel; Mehrad, Mitra; Strollo, Diane C; Leader, Joseph K; Wenzel, Sally; Yousem, Samuel A

    2017-02-01

    The histologic changes occurring in severe/therapy-resistant asthma (SA) as defined by the European Respiratory Society/American Thoracic Society guidelines, particularly at the level of the distal airways are unknown. This study describes the clinical, radiologic, and histologic characteristics of 29 SA patients who underwent video-assisted thoracoscopic surgery lung biopsy. Pathologic observations were correlated with clinical features, especially the presence of autoimmune disease (AID) (15/29, 51.7%). Ten biopsies (10/29, 34.5%) showed only small airway manifestations of asthma, whereas in 19 (65.5%) asthmatic granulomatosis, manifested by asthmatic bronchiolitis supplemented by an alveolar septal mononuclear infiltrates with non-necrotizing granulomas, was present. SA patients without asthmatic granulomatosis showed more striking small airway injury, subbasement membrane thickening, and neutrophilic infiltrates. Cases with concurrent AID had a tendency to more parenchymal eosinophilic inflammation, more bronchiolocentric granulomas, and a suggestion of increased responsivity to nonsteroidal immunosuppressive therapy. Histologic examination of video-assisted thoracoscopic surgery lung biopsies in SA demonstrates diverse pathologies including cases associated with granulomatous inflammation in addition to eosinophilic infiltrates. This spectrum of histologies may link to a high incidence of AID.

  16. Positive and negative mood following imaging-guided core needle breast biopsy and receipt of biopsy results.

    PubMed

    Perlman, Katherine L; Shelby, Rebecca A; Wren, Anava A; Kelleher, Sarah A; Dorfman, Caroline S; O'Connor, Erin; Kim, Connie; Johnson, Karen S; Soo, Mary Scott

    2017-12-01

    Positive and negative mood are independent psychological responses to stressful events. Negative mood negatively impacts well-being and co-occurring positive mood leads to improved adjustment. Women undergoing core needle breast biopsies (CNB) experience distress during CNB and awaiting results; however, influences of mood are not well known. This longitudinal study examines psychosocial and biopsy- and spirituality-related factors associated with mood in patients day of CNB and one week after receiving results. Ninety women undergoing CNB completed questionnaires on psychosocial factors (chronic stress, social support), biopsy experiences (pain, radiologist communication), and spirituality (peace, meaning, faith) day of CNB. Measures of positive and negative mood were completed day of CNB and one week after receiving results (benign n = 50; abnormal n = 25). Multiple linear regression analyses were conducted. Greater positive mood correlated with greater peace (β = .25, p = .02) day of CNB. Lower negative mood correlated with greater peace (β = -.29, p = .004) and there was a trend for a relationship with less pain during CNB (β = .19, p = .07). For patients with benign results, day of CNB positive mood predicted positive mood post-results (β = .31, p = .03) and only chronic stress predicted negative mood (β = .33, p = .03). For women with abnormal results, greater meaning day of CNB predicted lower negative mood post-results (β = -.45, p = .03). Meaning and peace may be important for women undergoing CNB and receiving abnormal results.

  17. Computer-assisted brush-biopsy analysis for the detection of dysplasia in a high-risk Barrett's esophagus surveillance population.

    PubMed

    Anandasabapathy, Sharmila; Sontag, Stephen; Graham, David Y; Frist, Stephen; Bratton, Joan; Harpaz, Noam; Waye, Jerome D

    2011-03-01

    Barrett's epithelial dysplasia, the direct precursor to esophageal adenocarcinoma, is often unapparent and frequently missed during surveillance of Barrett's esophagus with four-quadrant forceps biopsy protocol. To determine whether the detection of dysplasia is improved by adding computer-assisted brush biopsy (EndoCDx©) to four-quadrant biopsy protocol. Patients with a history of Barrett's esophagus with dysplasia scheduled for endoscopic surveillance were recruited from four academic medical centers. Patients underwent brush biopsy followed by four-quadrant biopsy every 1-2 cm. The results from brush and forceps biopsy were reviewed independently by pathologists blinded to the other's results. Among 151 patients enrolled (124 men, 27 women; mean age: 65), 117 (77.5%) had forceps and brush-biopsy specimens adequate for interpretation. The mean number of forceps biopsies was 11.9 (median 10, range 2-40) and brush biopsies was 2.0 (median 2, range 1-4). The overall yield of forceps alone was 25.2% (n = 38). Brush biopsy added an additional 16 positive cases increasing the yield of dysplasia detection by 42% (95% CI: 20.7-72.7). The number needed to test (NNT) to detect one additional case of dysplasia was 9.4 (95% CI: 6.4-17.7). There were no significant differences in results among different centers, between standard versus jumbo forceps, or between forceps biopsies taken every 1 cm versus every 2 cm. These data suggest that computer-assisted brush biopsy is a useful adjunct to standard endoscopic surveillance regimens for the identification of dysplasia in Barrett's esophagus.

  18. Development of Subischial Prosthetic Sockets with Vacuum-Assisted Suspension for Highly Active Persons with Transfemoral Amputations

    DTIC Science & Technology

    2012-10-01

    materials to facilitate dissemination of this technique. 15. SUBJECT TERMS Transfemoral amputation, sub-ischial socket, prosthesis , vacuum-assisted...an appropriate mechanical pump to create suitable vacuum for suspension of the prosthesis ...sockets of highly active prosthesis users

  19. Application of a single needle type for all image-guided biopsies: results of 100 consecutive core biopsies in various organs using a novel tri-axial, end-cut needle

    PubMed Central

    Diederich, S; Padge, B; Vossas, U; Hake, R; Eidt, S

    2006-01-01

    Purpose: To assess feasibility, results and complications in image-guided biopsies using a single needle design in various organs. Materials and methods: 100 consecutive percutaneous biopsies were performed in 54 females and 46 males aged 24–87 years (mean age/standard deviation: 64.5 +/− 12 years) using a full-core end-cut tri-axial full-automatic biopsy needle (18 gauge BioPince ™, InterV-MDTech, Gainesville, Florida) under CT (n=45) or ultrasound (n=55) guidance. In 63 biopsies a coaxial technique was used. Results: Biopsies were obtained of liver (n=32), lymph nodes (n=17), thyroid (n=11), lung (n=9), adrenal (n=9), pelvis (n=6), chest wall/pleura (n=6), mediastinum (n=4), lytic bone lesions (n=2), retroperitoneum (n=1), muscle (n=1), pancreas (n=1), peritoneum (n=1). Between 1 and 6 (mean/SD 2.83 +/− 0.92) needle passes were performed. In 77 cases a malignant (40 metastases, 37 primary tumours) and in 23 a benign lesion was diagnosed. Of the 23 benign lesions a specific diagnosis was possible in 22. In one case necrosis and haemorrhage was diagnosed. In this patient surgery and autopsy both revealed a mediastinal haematoma of unknown origin. Eight minor complications (mild pain/local haematoma requiring no therapy) and three major complications (three pneumothoraces in nine lung biopsies requiring two aspirations and one drainage) were observed. There was no mortality. Conclusion: Percutaneous image-guided biopsy using the described full-core end-cut needle resulted in a specific diagnosis in 99/100 consecutive biopsies in various organs with a low complication rate. We use this needle type for all CT- or US-guided biopsies in all organs except for solid bone. PMID:16766268

  20. Computer assisted optical biopsy for colorectal polyps

    NASA Astrophysics Data System (ADS)

    Navarro-Avila, Fernando J.; Saint-Hill-Febles, Yadira; Renner, Janis; Klare, Peter; von Delius, Stefan; Navab, Nassir; Mateus, Diana

    2017-03-01

    We propose a method for computer-assisted optical biopsy for colorectal polyps, with the final goal of assisting the medical expert during the colonoscopy. In particular, we target the problem of automatic classification of polyp images in two classes: adenomatous vs non-adenoma. Our approach is based on recent advancements in convolutional neural networks (CNN) for image representation. In the paper, we describe and compare four different methodologies to address the binary classification task: a baseline with classical features and a Random Forest classifier, two methods based on features obtained from a pre-trained network, and finally, the end-to-end training of a CNN. With the pre-trained network, we show the feasibility of transferring a feature extraction mechanism trained on millions of natural images, to the task of classifying adenomatous polyps. We then demonstrate further performance improvements when training the CNN for our specific classification task. In our study, 776 polyp images were acquired and histologically analyzed after polyp resection. We report a performance increase of the CNN-based approaches with respect to both, the conventional engineered features and to a state-of-the-art method based on videos and 3D shape features.

  1. CT-Guided Transthoracic Core Biopsy for Pulmonary Tuberculosis: Diagnostic Value of the Histopathological Findings in the Specimen

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Fukuda, Hozumi, E-mail: fkdhzmrad@mitsuihosp.or.jp; Ibukuro, Kenji; Tsukiyama, Toshitaka

    We evaluated the value of CT-guided transthoracic core biopsy for the diagnosis of mycobacterial pulmonary nodules. The 30 subjects in this study had pulmonary nodules that had been either diagnosed histopathologically as tuberculosis or were suspected as tuberculosis based on a specimen obtained by CT-guided transthoracic core biopsy. The histopathological findings, the existence of acid-fast bacilli in the biopsy specimens, and the clinical course of the patients after the biopsy were reviewed retrospectively. Two of the three histological findings for tuberculosis that included epithelioid cells, multinucleated giant cells and caseous necrosis were observed in 21 of the nodules which weremore » therefore diagnosed as histological tuberculosis. Six of these 21 nodules were positive for acid-fast bacilli, confirming the diagnosis of tuberculosis. Thirteen of the 21 nodules did not contain acid-fast bacilli but decreased in size in response to antituberculous treatment and were therefore diagnosed as clinical tuberculosis. Seven nodules with only caseous necrosis were diagnosed as suspected tuberculosis, with a final diagnosis of tuberculosis being made in 4 of the nodules and a diagnosis of old tuberculosis in 2 nodules. Two nodules with only multinucleated giant cells were diagnosed as suspected tuberculosis with 1 of these nodules being diagnosed finally as tuberculosis and the other nodule as a nonspecific granuloma. When any two of the three following histopathological findings - epithelioid cells, multinucleated giant cells or caseous necrosis - are observed in a specimen obtained by CT-guided transthoracic core biopsy, the diagnosis of tuberculosis can be established without the detection of acid-fast bacilli or Mycobacterium tuberculosis.« less

  2. Development of Subischial Prosthetic Sockets with Vacuum-Assisted Suspension for Highly Active Persons with Transfemoral Amputations

    DTIC Science & Technology

    2014-10-01

    Award Number: W81XWH-10-1-0744 TITLE: Development of Subischial Prosthetic Sockets with Vacuum...REPORT TYPE Annual 3. DATES COVERED 15 Sep 2013 – 14 Sep 2014 4. TITLE AND SUBTITLE Development of Subischial Prosthetic Sockets with Vacuum...to develop a highly flexible sub-ischial prosthetic socket with assisted-vacuum suspension for highly active persons with transfemoral amputation. The

  3. Protection of polyphenols in blueberry juice by vacuum-assisted block freeze concentration.

    PubMed

    Orellana-Palma, Patricio; Petzold, Guillermo; Pierre, Lissage; Pensaben, José Manuel

    2017-11-01

    Block freeze concentration allows produces high-quality cryoconcentrates with important protection of valuable components from fresh fruit juices. The aim of this study was to investigate the use of vacuum-assisted block freeze concentration under different experimental conditions to protect polyphenols in the elaboration of concentrated blueberry juice. Fresh blueberry juice was radial or unidirectional frozen at -20 and -80 °C for 12 h and vacuum process was performed at 80 kPa during 120 min. Results showed a significant solute increased in the concentrated fraction in all treatments, and the best treatment was - 20 °C/unidirectional with a value of ≈63 °Brix, equivalent to an increase of 3.8 times in the total polyphenol content (76% of retention). The color of concentrated samples was darker than the initial sample, with ΔE* values of >25 CIELab units in all treatments. The vacuum-assisted block freeze concentrations was an effective technology for protecting polyphenols and obtain a concentrated with a higher concentration of solids from blueberry juice, as well as interesting values of process parameters. Copyright © 2017 Elsevier Ltd. All rights reserved.

  4. [Assessment of vacuum-assisted vaginal delivery in a frank breech presentation].

    PubMed

    Bleu, G; Deruelle, P; Demetz, J; Michel, S; Dufour, P; Depret, S; Subtil, D

    2015-02-01

    After verification of the eligibility criteria and with an obstetrician familiar with the specific maneuvers likely to be needed, vaginal delivery of breech presentations is possible. If problems arise during the active pushing phase of labor, vacuum extraction has been described in the literature for this uncommon condition with limited series. The aim of this study is to assess retrospectively vacuum extraction in frank breech presentation in our center. This retrospective study of trials of vaginal delivery of fetuses in breech presentation at term compares cases according to whether they did or did not use a vacuum extraction. During a two-year period, 83 patients, whom had trials of vaginal delivery in breech presentations, reached the active pushing/bearing down stage after complete cervical dilatation. Vacuum assistance was applied in six of these (7.2 %). The failure rate for vaginal delivery was significantly higher in the group with compared to without vacuum extraction (33.3 % versus 6.5 %, P<0.05). Moreover, the mean pH at birth was significantly lower in the group with vacuum extraction (7.12±0.11 versus 7.20±0.08, P<0.05), and these infants more frequently had deep cutaneous injuries (66.7 % versus 26.0 %, P<0.05). In fetuses in breech presentation, when vaginal delivery failed, it seems to be safer for the fetuses to perform caesarean section rather than attempt vacuum extraction. Copyright © 2015 Elsevier Masson SAS. All rights reserved.

  5. Radial scars diagnosed on breast core biopsy: Frequency of atypia and carcinoma on excision and implications for management.

    PubMed

    Donaldson, Alana R; Sieck, Leah; Booth, Christine N; Calhoun, Benjamin C

    2016-12-01

    The risk of finding carcinoma in excisions following a core needle biopsy diagnosis of radial scar is not well defined and clinical management is variable. The aim of this study is to determine the frequency of high-risk lesions, ductal carcinoma in situ, and invasive carcinoma in excisions following a core biopsy diagnosis of radial scar. Dedicated breast pathologists and radiologists correlated the histologic and radiologic findings and categorized radial scars as the target lesion or an incidental finding. High-risk lesions were defined as atypical hyperplasia or classical lobular carcinoma in situ. Of the 79 radial scars identified over a 14-year period, 22 were associated with atypia or carcinoma in the core biopsy. Thirty-seven (37) of the 57 benign radial scars underwent excision with benign findings in 30 (81%), high-risk lesions in six (16%), and flat epithelial atypia in one (3%). There were no upgrades to carcinoma. One patient with a benign radial scar developed a 3-mm focus of intermediate-grade estrogen receptor-positive ductal carcinoma in situ in the same quadrant of the ipsilateral breast 72 months after excision. One patient with an incidental un-excised benign radial scar was diagnosed with ductal carcinoma in situ at a separate site of suspicious calcifications. In this series, none of the benign radial scars was upgraded to carcinoma. Radial scar was the targeted lesion in all cases with high-risk lesions on excision. Surgical excision may not be mandatory for patients with benign incidental radial scars on core biopsy. Copyright © 2016 Elsevier Ltd. All rights reserved.

  6. Rapid three-dimensional analysis of renal biopsy sections by low vacuum scanning electron microscopy.

    PubMed

    Inaga, Sumire; Kato, Masako; Hirashima, Sayuri; Munemura, Chishio; Okada, Sinichi; Kameie, Toshio; Katsumoto, Tetsuo; Nakane, Hironobu; Tanaka, Keiichi; Hayashi, Kazuhiko; Naguro, Tomonori

    2010-01-01

    Renal biopsy paraffin sections were examined by low vacuum scanning electron microscopy (LVSEM) in the backscattered electron (BSE) mode, a novel method for rapid pathological analysis which allowed detailed and efficient three-dimensional observations of glomeruli. Renal samples that had been already diagnosed by light microscopy (LM) as exhibiting IgA nephropathy, minor glomerular abnormalities, and membranous glomerulonephritis (GN) were rapidly processed in the present study. Unstained paraffin sections of biopsy samples on glass slides were deparaffinized, stained with platinum blue (Pt-blue) or periodic acid silver-methenamine (PAM), and directly observed with a LVSEM. Overviews of whole sections and detailed observations of individual glomeruli were immediately performed at arbitrary magnifications between ×50 to ×18,000. Cut surface views and surface views of glomeruli were demonstrated at the same time. On Pt-blue-stained sections, podocytes, endothelia, mesangium, and glomerular basement membranes (GBMs) could be distinguished due to the different yields of BSE signals, and pathological features were investigated in every sample. The abnormal surface appearances of podocytes with foot processes and the varying thicknesses of GBM were revealed three-dimensionally, features difficult to observe under LM and transmission electron microscopy. PAM-positive GBM alterations in membranous GN were distinctly visualized through overlying cells without cell removal under LVSEM at high magnification. Not only prominent spike formation but also slight protrusions were clearly revealed in the side views of GBM. Crater-like or hole-like structures were shown in the en face views of GBM. Accordingly, LVSEM is expected to provide a novel approach to the pathological diagnosis of human glomerular diseases using conventional renal biopsy sections.

  7. Distinguishing papillary endothelial hyperplasia and angiosarcoma on core needle biopsy of the breast: The importance of clinical and radiologic correlation.

    PubMed

    Guilbert, Marie-Christine; Frost, Elisabeth P; Brock, Jane E; Lester, Susan C

    2018-02-24

    Papillary endothelial hyperplasia (PEH) is a rare non-neoplastic exuberant organizing hematoma that can closely mimic angiosarcoma due to a resemblance to malignant anastomosing blood vessels. It could be particularly difficult to distinguish PEH from angiosarcoma in breast core needle biopsies. We identified all cases of these lesions diagnosed on core needle biopsy in order to identify clinical, radiologic, and pathologic features that could prove helpful to arrive at the correct diagnosis. Four cases of PEH and 4 cases of angiosarcoma were identified. The mean age at diagnosis was 62 for PEH and 33 for primary angiosarcoma. All cases of PEH formed small masses with circumscribed or lobulated margins by imaging (mean size 0.9 cm). In 3 cases, the masses were difficult or impossible to identify after the biopsy. Angiosarcomas presented as larger masses with ill-defined margins (mean size 2.8 cm) that were unchanged in size after biopsy. PEH was surrounded by adipose tissue, whereas angiosarcoma invaded into fibrous stroma and involved lobules. The pseudopapillary structures of PEH were composed mainly of collagen, and thus, additional histologic stains for fibrin were not helpful for diagnosis. The 4 patients with PEH received no further treatment and are alive and disease-free at 2-11 years of follow-up. In contrast, the patients with angiosarcoma underwent mastectomy and chemotherapy or radiation therapy. Two of the patients with angiosarcoma died 3 years after diagnosis and the other 2 patients are alive without disease at 5 and 6 years. Therefore, distinguishing PEH and angiosarcoma is essential for appropriate management. This is the first series to compare these lesions on core needle biopsy and the first to note important clinical, imaging, and histologic differences that aid in making a diagnosis of PEH with confidence on breast core needle biopsy. © 2018 Wiley Periodicals, Inc.

  8. Vacuum-assisted fluid flow in microchannels to pattern substrates and cells.

    PubMed

    Shrirao, Anil B; Kung, Frank H; Yip, Derek; Cho, Cheul H; Townes-Anderson, Ellen

    2014-09-01

    Substrate and cell patterning are widely used techniques in cell biology to study cell-to-cell and cell-substrate interactions. Conventional patterning techniques work well only with simple shapes, small areas and selected bio-materials. This paper describes a method to distribute cell suspensions as well as substrate solutions into complex, long, closed (dead-end) polydimethylsiloxane (PDMS) microchannels using negative pressure. Our method builds upon a previous vacuum-assisted method used for micromolding (Jeon et al 1999 Adv. Mater 11 946) and successfully patterned collagen-I, fibronectin and Sal-1 substrates on glass and polystyrene surfaces, filling microchannels with lengths up to 120 mm and covering areas up to 13 × 10 mm(2). Vacuum-patterned substrates were subsequently used to culture mammalian PC12 and fibroblast cells and amphibian neurons. Cells were also patterned directly by injecting cell suspensions into microchannels using vacuum. Fibroblast and neuronal cells patterned using vacuum showed normal growth and minimal cell death indicating no adverse effects of vacuum on cells. Our method fills reversibly sealed PDMS microchannels. This enables the user to remove the PDMS microchannel cast and access the patterned biomaterial or cells for further experimental purposes. Overall, this is a straightforward technique that has broad applicability for cell biology.

  9. Vacuum-assisted Fluid Flow in Microchannels to Pattern Substrates and Cells

    PubMed Central

    Shrirao, Anil B.; Kung, Frank H.; Yip, Derek; Cho, Cheul H.; Townes-Anderson, Ellen

    2014-01-01

    Substrate and cell patterning are widely used techniques in cell biology to study cell-to-cell and cell-to-substrate interactions. Conventional patterning techniques work well only with simple shapes, small areas and selected bio-materials. This paper describes a method to distribute cell suspensions as well as substrate solutions into complex, long, closed (dead-end) polydimethylsiloxane (PDMS) microchannels using negative pressure. Our method builds upon a previous vacuum-assisted method used for micromolding (Jeon, Choi et al. 1999) and successfully patterned collagen-I, fibronectin and Sal-1 substrates on glass and polystyrene surfaces, filling microchannels with lengths up to 120 mm and covering areas up to 13 × 10 mm2. Vacuum-patterned substrates were subsequently used to culture mammalian PC12 and fibroblast cells and amphibian neurons. Cells were also patterned directly by injecting cell suspensions into microchannels using vacuum. Fibroblast and neuronal cells patterned using vacuum showed normal growth and minimal cell death indicating no adverse effects of vacuum on cells. Our method fills reversibly sealed PDMS microchannels. This enables the user to remove the PDMS microchannel cast and access the patterned biomaterial or cells for further experimental purposes. Overall, this is a straightforward technique that has broad applicability for cell biology. PMID:24989641

  10. Transnasal Endoscopic Biopsy Approach to Atlas Tumor with X-ray Assisted and Related Radiographic Measure.

    PubMed

    Li, Zhen-Feng; Shao, Xian-Hao; Zhang, Li-Qiang; Yang, Zhi-Ping; Li, Xin; Yang, Qiang; Li, Jian-Min

    2016-05-01

    To develop an endoscopic transnasal approach to atlas tumors and study its practicability. This article comprises two components: an illustrative case report and observational data on 50 volunteers. As to the case report, a 34 year old man presented with occipital pain for more than 3 months and underwent systematic investigation in Qilu Hospital of Shandong University. CT and MRI scans showed bony destruction in the craniovertebral junction (CVJ) suggestive of tumor. Via an endoscopic transnasal approach to the suspected atlas tumor through the inferior nasal meatus, a Gallini biopsy needle was used to obtain tissue for examination. The procedure was performed endoscopically with double orientation X-ray guidance and coaxial technology after establishing the shortest distance for the biopsy track and range of target tissue and was assisted by manual palpation. As to the observational data, 50 volunteers underwent atlas-related morphometric image measurement using gemstone CT equipment. Biopsy track angles, range for biopsy of the atlas and biopsy track distances were measured by a blinded operator on CT images. pathological examination of the biopsy resulted in diagnosis of a chordoma. There were no complications such as bleeding, infection or spinal cord injury. One month later, the patient underwent tumor resection and reconstruction in other hospital and the diagnosis of chordoma was confirmed by pathological examination of the resected specimen. Observational data: measurements obtained from CT scans of the 50 volunteers were as follows. Biopsy track angles: mean leaning inside angle 3.53° ± 0.39° and mean posterior slope angle 13.05° ± 1.39°. Range for atlas biopsy: transverse diameter 11.84 ± 1.24 mm and longitudinal diameter 9.67 ± 0.90 mm. Biopsy track distances: from atlas to nostril, and to anterior and posterior edges of the inferior turbinate mucosa were 94.52 ± 5.03 mm, 78.21 ± 4.63 mm, and 33.51 ± 3.13

  11. [Cost-effectiveness of percutaneous core needle breast biopsy (CNBB) versus open surgical biopsy (OSB) of nonpalpable breast lesions: metaanalysis and cost evaluation for German-speaking countries].

    PubMed

    Gruber, R; Bernt, R; Helbich, T H

    2008-02-01

    To analyze the cost-effectiveness of percutaneous image-guided CNBB (stereotactic-/ultrasound-guided; large/vacuum-assisted) of non-palpable breast lesions vs. OSB and to compare and discuss the results reported in the literature with results for German-speaking countries. A key word search in three databases, limited to the period from 1/1994 to 12/2006 was performed. Only original papers were selected. No published articles for German-speaking countries were identified; therefore a comprehensive data collection was made. On the basis of 377 abstracts, nine studies were evaluated for final assessment. The data of German-speaking countries were compared with results reported in the literature. This study demonstrates that CNBB compared to OSB leads to reduction in cost ranging from 51-96 %. The cost reduction depends on biopsy modality and lesion type and is subject to national fluctuations. CNBB can replace a surgical procedure in 71-85 % of cases. Use of CNBB as an alternative to OSB has the potential to substantially reduce healthcare costs. The data are based almost exclusively on the North American literature. A potential cost reduction in the Netherlands and Switzerland confirms these findings. Future work must include cost evaluation studies for German-speaking countries since this is an issue with important national economic ramifications.

  12. Asymptomatic Benign Papilloma Without Atypia Diagnosed at Ultrasonography-Guided 14-Gauge Core Needle Biopsy: Which Subgroup can be Managed by Observation?

    PubMed

    Kim, Soo-Yeon; Kim, Eun-Kyung; Lee, Hye Sun; Kim, Min Jung; Yoon, Jung Hyun; Koo, Ja Seung; Moon, Hee Jung

    2016-06-01

    For asymptomatic benign papillomas detected at ultrasonography-guided 14-gauge core-needle biopsy (US-CNB), the decision to perform excision versus observation has been a topic of debate. We sought to determine which subgroup of asymptomatic benign papillomas without atypia diagnosed at US-CNB can be safely managed by observation versus immediate excision. Overall, 230 asymptomatic benign papillomas in 197 women (mean age 46.6 ± 9.5 years; range 22-78), diagnosed at US-CNB using immunohistochemistry staining when needed and then managed by surgery (n = 144) or vacuum-assisted excision (VAE) with at least 12 months of follow-up after benign VAE results (n = 86) were included in this study. The upgrade rate to malignancy was calculated. Clinical and radiological variables, including age, size, Breast Image Reporting and Data System (BI-RADS) category, and imaging-pathology correlation were evaluated to find associations with malignancy using multivariate analysis. The upgrade rate to malignancy was 2.6 % (6 of 230): four were ductal carcinomas in situ and two were 1.5- and 9-mm-sized invasive ductal carcinomas without lymph node metastasis. The upgrade rates of papillomas with a BI-RADS category 3-4a and imaging-pathology concordance were 1.4 and 1.8 %, respectively. Category 4b-5 and imaging-pathology discordance were independently associated with malignancy, with upgrade rates of 13 and 50 %, respectively. Age and lesion size were not associated with malignancy. Asymptomatic benign papillomas with probable benign or low suspicious US features or imaging-pathology concordance can be followed-up as opposed to immediate excision.

  13. Vacuum-Assisted, Constant-Force Exercise Device

    NASA Technical Reports Server (NTRS)

    Hansen, Christopher P.; Jensen, Scott

    2006-01-01

    The vacuum-assisted, constant-force exercise device (VAC-FED) has been proposed to fill a need for a safe, reliable exercise machine that would provide constant loads that could range from 20 to 250 lb (0.09 to 1.12 kN) with strokes that could range from 6 to 36 in. (0.15 to 0.91 m). The VAC-FED was originally intended to enable astronauts in microgravity to simulate the lifting of free weights, but it could just as well be used on Earth for simulated weight lifting and other constant-force exercises. Because the VAC-FED would utilize atmospheric/vacuum differential pressure instead of weights to generate force, it could weigh considerably less than either a set of free weights or a typical conventional exercise machine based on weights. Also, the use of atmospheric/ vacuum differential pressure to generate force would render the VAC-FED inherently safer, relative to free weights and to conventional exercise machines that utilize springs to generate forces. The overall function of the VAC-FED would be to generate a constant tensile force in an output cable, which would be attached to a bar, handle, or other exercise interface. The primary force generator in the VAC-FED would be a piston in a cylinder. The piston would separate a volume vented to atmosphere at one end of the cylinder from an evacuated volume at the other end of the cylinder (see figure). Hence, neglecting friction at the piston seals, the force generated would be nearly constant equal to the area of the piston multiplied by the atmospheric/vacuum differential pressure. In the vented volume in the cylinder, a direct-force cable would be looped around a pulley on the piston, doubling the stroke and halving the tension. One end of the direct-force cable would be anchored to a cylinder cap; the other end of the direct-force cable would be wrapped around a variable-ratio pulley that would couple tension to the output cable. As its name suggests, the variable-ratio pulley would contain a mechanism that

  14. Development of Sub-Ischial Prosthetic Sockets with Vacuum-Assisted Suspension for Highly Active Persons with Transfemoral Amputations

    DTIC Science & Technology

    2013-10-01

    15. SUBJECT TERMS Transfemoral amputation, sub-ischial socket, prosthesis , vacuum-assisted suspension 16. SECURITY CLASSIFICATION OF: 17...vacuum for suspension of the prosthesis ...14 Task 6 Determine range of volumes to be evacuated from transfemoral sockets of highly active prosthesis users

  15. Prospective evaluation of magnetic resonance imaging guided in-bore prostate biopsy versus systematic transrectal ultrasound guided prostate biopsy in biopsy naïve men with elevated prostate specific antigen.

    PubMed

    Quentin, Michael; Blondin, Dirk; Arsov, Christian; Schimmöller, Lars; Hiester, Andreas; Godehardt, Erhard; Albers, Peter; Antoch, Gerald; Rabenalt, Robert

    2014-11-01

    Magnetic resonance imaging guided biopsy is increasingly performed to diagnose prostate cancer. However, there is a lack of well controlled, prospective trials to support this treatment method. We prospectively compared magnetic resonance imaging guided in-bore biopsy with standard systematic transrectal ultrasound guided biopsy in biopsy naïve men with increased prostate specific antigen. We performed a prospective study in 132 biopsy naïve men with increased prostate specific antigen (greater than 4 ng/ml). After 3 Tesla functional multiparametric magnetic resonance imaging patients were referred for magnetic resonance imaging guided in-bore biopsy of prostate lesions (maximum 3) followed by standard systematic transrectal ultrasound guided biopsy (12 cores). We analyzed the detection rates of prostate cancer and significant prostate cancer (greater than 5 mm total cancer length or any Gleason pattern greater than 3). A total of 128 patients with a mean ± SD age of 66.1 ± 8.1 years met all study requirements. Median prostate specific antigen was 6.7 ng/ml (IQR 5.1-9.0). Transrectal ultrasound and magnetic resonance imaging guided biopsies provided the same 53.1% detection rate, including 79.4% and 85.3%, respectively, for significant prostate cancer. Magnetic resonance imaging and transrectal ultrasound guided biopsies missed 7.8% and 9.4% of clinically significant prostate cancers, respectively. Magnetic resonance imaging biopsy required significantly fewer cores and revealed a higher percent of cancer involvement per biopsy core (each p <0.01). Combining the 2 methods provided a 60.9% detection rate with an 82.1% rate for significant prostate cancer. Magnetic resonance imaging guided in-bore and systematic transrectal ultrasound guided biopsies achieved equally high detection rates in biopsy naïve patients with increased prostate specific antigen. Magnetic resonance imaging guided in-bore biopsies required significantly fewer cores and revealed a

  16. FNAC Versus Core Needle Biopsy: A Comparative Study in Evaluation of Palpable Breast Lump

    PubMed Central

    Saha, Abhijit; Mukhopadhyay, Madhumita; Sarkar, Koushik; Saha, Ashis Kumar; Sarkar, Diptendra KR

    2016-01-01

    Introduction Breast carcinoma is the most common malignant tumour and the leading cause of carcinoma death in women in world. The main purpose of FNAC or CNB of breast lumps is to confirm cancer preoperatively and to avoid unnecessary surgery in specific benign conditions. Aims and Objective The objective of the study was to compare between Fine Needle Aspiration Cytology (FNAC) and Core Needle Biopsy (CNB) in the diagnosis of breast carcinoma with final histological diagnosis from excision specimen as it is gold standard. Materials and Methods A prospective study was done on 50 cases. Patients undergoing all three procedures (Fine Needle Aspiration Cytology and Core Needle Biopsy done at Department of Pathology; subsequent excision surgeries done at Department of General Surgery) were selected. May Grunwald Giemsa (MGG) and Papaniculou (PAP) staining were performed on cytology smears. Haematoxylin and Eosin (H&E) staining was done on both the CNB and tissue specimens obtained from subsequent excision surgeries to see the histological features. Results FNAC showed sensitivity, specificity, positive predictive value, negative predictive value, and diagnostic accuracy were 69%, 100%, 100%, 38.1%, and 74% respectively in diagnosing carcinoma. CNB had sensitivity, specificity, positive predictive value, negative predictive value, and diagnostic accuracy of 88.3%, 100%, 100%, 53.3% and 86%. Both FNAC and CNB showed statistically significant correlation with confirmatory HPE of excision specimen (p-value <0.05) in the diagnosis of breast carcinoma. Conclusion Fine needle aspiration cytology (FNAC) is a rapid, less complicated, economical, reliable and relevant method for the preoperative pathological diagnosis of breast carcinoma in a developing nation like ours. If the initial FNAC is inadequate, core needle biopsy (CNB) can be a useful second line method of pathological diagnosis in order to minimize the chance of missed diagnosis of breast cancer. PMID:27042469

  17. Active surveillance is suitable for intermediate term follow-up of renal oncocytoma diagnosed by percutaneous core biopsy.

    PubMed

    Liu, Shuo; Lee, Stephen; Rashid, Prem; Bangash, Haider; Hamid, Akhlil; Lau, Jason; Cohen, Ronald

    2016-10-01

    To evaluate the intermediate outcome of conservative management in patients with biopsy-proven oncocytoma. Patients with oncocytoma diagnosed on percutaneous core biopsy between January 2000 to December 2014 were identified from the renal biopsy database of a large specialist urologic pathology laboratory. After review of patient clinical records, the study cohort comprised only of patients enrolled in active surveillance. Clinicopathological and follow-up details were reviewed for each case, in particular: type and interval of surveillance imaging, tumour growth, definitive intervention and reason for intervention. Where possible, correlation was made between the final surgical and the initial biopsy specimens. Fifty three patients diagnosed with oncocytoma on core biopsy were initially placed on active surveillance with median follow-up of 34 months (range 6-109). The median age at diagnosis was 65 years (range 20-85) and median tumour size was 30 mm (range 13-87). Mean average tumour growth was 1.4 mm per annum (median 0 mm/year) with the majority (36 of 53, 68%) exhibiting minimal growth (less than 2 mm per annum) or partial regression. Forty seven of the 53 patients remained on active surveillance with no significant progression. Six patients elected to undergo definitive intervention (five surgical excision, one ablation). Renal oncocytoma was confirmed in all five patients who underwent surgical excision of their lesions. The majority of oncocytomas in this study showed minimal growth rate or regression. Patients with biopsy proven oncocytoma can be conservatively managed with active surveillance. © 2016 The Authors BJU International © 2016 BJU International Published by John Wiley & Sons Ltd.

  18. Differences in accuracy and underestimation rates for 14- versus 16-gauge core needle biopsies in ultrasound-detectable breast lesions.

    PubMed

    Lai, Hung-Wen; Wu, Hwa-Koon; Kuo, Shou-Jen; Chen, Shou-Tung; Tseng, Hsin-Shun; Tseng, Ling-Ming; Chen, Dar-Ren

    2013-04-01

    Core needle biopsy (CNB) was widely used in the diagnosis of ultrasound-detectable breast lesions. We aimed at assessing the diagnostic performance differences between 14- and 16-gauge ultrasound-guided core biopsies. This retrospective study enrolled patients receiving CNB from January 2001 to December 2007. The results of 14- and 16-gauge breast CNBs were compared with pathology reports of open surgical biopsy (OSB). A total of 1024 paired CNB and OSB results were obtained from 1732 CNB procedures in 1630 patients.Those CNB results reached 92.9% sensitivity, 99.7% specificity, 5.96% underestimation, and 94.8% accuracy rates. There was no difference in sensitivity (p=0.17) or specificity (p=0.38) between 14- and 16-gauge needles. However, better overall accuracy (p=0.02), less underestimation (p<0.001), and lower false-negative (p=0.02) rates were found for the 14-gauge CNB. Regarding accuracy and underestimation rates, a 14-gauge needle is preferred to a 16-gauge one in ultrasound-guided biopsies. Copyright © 2012. Published by Elsevier B.V.

  19. Intraoperative loss of core biopsy clips: clinical implications.

    PubMed

    Calhoun, Kristine; Giuliano, Armando; Brenner, R James

    2008-03-01

    The purpose of this study was to report the occurrence of intraoperative loss of metallic marking clips placed during image-guided biopsy and to hypothesize the likely mechanism of this clinical problem. From January 2003 through December 2004, patients presenting for preoperative mammographic localization and operative excision of biopsy site marking clips were identified. Age, method of image-guided biopsy, number of excised specimens, and tissue diagnosis were determined. Specimen radiographs were used to identify cases of suspected intraoperative clip loss. Clips absent on specimen radiographs and postoperative mammograms were defined as lost intraoperatively. Biopsy site marking clips, surgical clips, and suction device apertures were measured. In 78 surgical procedures performed during the study period, three (3.8%) of the patients experienced clip loss. Specimen radiographs confirmed the absence of clips in all submitted tissues. A median of four (range, three to five) separate biopsy specimens were excised among these three cases. A healing biopsy site from the stereotactic biopsy preceding the clip placement procedure was confirmed in all cases. Absence of the metallic clip was confirmed on postoperative mammograms. The apertures of two types of suction device were four and two times those of the biopsy clips. Intraoperative loss of metallic clips placed at the conclusion of image-guided breast biopsy is unusual but can occur during subsequent surgical excision. Repeated inability to locate the clip on specimen radiographs after accurate preoperative localization should raise the suspicion that the target clip has been lost, not missed, during surgery, likely because of inadvertent removal of the clip with the suction device.

  20. Direct comparison of the diagnostic yield of ultrasound-assisted Abrams and Tru-Cut needle biopsies for pleural tuberculosis.

    PubMed

    Koegelenberg, Coenraad Frederik N; Bolliger, Christoph Thomas; Theron, Johan; Walzl, Gerhard; Wright, Colleen Anne; Louw, Mercia; Diacon, Andreas Henri

    2010-10-01

    Tuberculous pleuritis remains the commonest cause of exudative effusions in areas with a high prevalence of tuberculosis and histological and/or microbiological confirmation on pleural tissue is the gold standard for its diagnosis. Uncertainty remains regarding the choice of closed pleural biopsy needles. This prospective study compared ultrasound-assisted Abrams and Tru-Cut needle biopsies with regard to their diagnostic yield for pleural tuberculosis. 89 patients (54 men) of mean ± SD age 38.7 ± 16.7 years with pleural effusions and a clinical suspicion of tuberculosis were enrolled in the study. Transthoracic ultrasound was performed on all patients, who were then randomly assigned to undergo ≥ 4 Abrams needle biopsies followed by ≥ 4 Tru-Cut needle biopsies or vice versa. Medical thoracoscopy was performed on cases with non-diagnostic closed biopsies. Histological and/or microbiological proof of tuberculosis on any pleural specimen was considered the gold standard for pleural tuberculosis. Pleural tuberculosis was diagnosed in 66 patients, alternative diagnoses were established in 20 patients and 3 remained undiagnosed. Pleural biopsy specimens obtained with Abrams needles contained pleural tissue in 81 patients (91.0%) and were diagnostic for tuberculosis in 54 patients (sensitivity 81.8%), whereas Tru-Cut needle biopsy specimens only contained pleural tissue in 70 patients (78.7%, p=0.015) and were diagnostic in 43 patients (sensitivity 65.2%, p=0.022). Ultrasound-assisted pleural biopsies performed with an Abrams needle are more likely to contain pleura and have a significantly higher diagnostic sensitivity for pleural tuberculosis.

  1. Can magnetic resonance imaging obviate the need for biopsy for microcalcifications?

    PubMed Central

    Chishima, Takashi

    2017-01-01

    Background Although microcalcifications detected with mammography (MG) are usually biopsied, biopsies cannot be performed in all cases. We sought to determine if magnetic resonance imaging (MRI) findings could indicate whether stereotactic vacuum-assisted biopsy (SVAB) is necessary. Methods Patients with mammographically detected Breast Imaging-Reporting and Data System (BI-RADS) 3, 4, and 5 microcalcifications were analyzed from April 2012 to September 2014. All patients underwent MRI. All patients with enhancing lesions in the region of the microcalcifications underwent SVAB. Non-enhancing lesions were followed or biopsied, depending on the patient's preferences. MRI findings were classified as either malignant-suspicious or benign-suspicious (“none” or “nonspecific”), and we evaluated the positive predictive value (PPV) and negative predictive value (NPV) of these classifications for predicting malignancy. Results A total of 87 patients underwent both MRI and SVAB. The NPV of MRI was 100% in the group with no enhancement. In BI-RADS category 3, there were 57 benign-suspicious lesions on MRI, of which eight were malignant (NPV of MRI: 85.0%). Conclusions It may be possible to omit SVAB for microcalcifications if there is no enhancement on MRI; however, any kind of enhancement indicates the need for biopsy in cases of BI-RADS 3 calcifications on MG. PMID:28861368

  2. Core needle biopsy guidance based on EMOCT imaging (Conference Presentation)

    NASA Astrophysics Data System (ADS)

    Iftimia, Nicusor V.; Park, Jesung; Maguluri, Gopi

    2016-03-01

    We present a novel method, based on encoder mapping OCT imaging, for real-time guidance of core biopsy procedures. This method provides real-time feedback to the interventional radiologist, such that he/she can reorient the needle during the biopsy and sample the most representative area of the suspicious mass that is being investigated. This aspect is very important for tailoring therapy to the specific cancer based on biomarker analysis, which will become one of the next big advances in our search for the optimal cancer therapy. To enable individualized treatment, the genetic constitution and the DNA repair status in the affected areas is needed for each patient. Thus, representative sampling of the tumor is needed for analyzing various biomarkers, which are used as a tool to personalize cancer therapy. The encoder-based OCT enables samping of large size masses and provides full control on the imaging probe, which is passed through the bore of the biopsy guidance needle. The OCT image is built gradually, based on the feedback of an optical encoder which senses the incremental movement of the needle with a few microns resolution. Tissue mapping is independent of the needle speed, while it is advanced through the tissue. The OCT frame is analyzed in real-time and tissue cellularity is reported in a very simple manner (pie chart). Our preliminary study on a rabbit model of cancer has demonstrated the capability of this technology for accurately differentiating between viable cancer and heterogeneous or necrotic tissue.

  3. Diagnostic accuracy of pre-treatment biopsy for grading cutaneous mast cell tumours in dogs.

    PubMed

    Shaw, T; Kudnig, S T; Firestone, S M

    2018-06-01

    Mast cell tumours (MCTs) are common tumours of the canine skin, and are estimated to represent up to 20% of all skin tumours in dogs. Tumour grade has a major impact on the incidence of local recurrence and metastatic potential. In addition to helping the clinician with surgical planning, knowledge of the tumour grade also assists in proper prognostication and client education. For pre-treatment biopsies to be useful, there must exist a high level of correlation between the histopathological grade obtained from the pre-treatment biopsy and the actual histopathological grade from the excisional biopsy. The aim of this study was to determine concordance of tumour grade between various biopsy techniques (wedge, punch, needle core) and the "gold standard" excisional biopsy method. We found an overall concordance rate of 96% based on the Patnaik grading system, and an overall concordance rate of 92% based on the Kiupel grading system. The accuracy of the various biopsy techniques (wedge, punch and needle core) when compared with excisional biopsy was 92%, 100% and 100%, respectively, based on the Patnaik grading system, and 90%, 95% and 100%, respectively, based on the Kiupel grading system. Of the cases with discordant results, the pre-treatment biopsies tended to underestimate the grade of the tumour. Based on these results, we conclude that pre-treatment biopsies are sufficiently accurate for differentiating low-grade from high-grade MCTs, regardless of biopsy technique or tumour location. © 2017 John Wiley & Sons Ltd.

  4. Diffuse intrinsic pontine gliomas in children: Interest of robotic frameless assisted biopsy. A technical note.

    PubMed

    Coca, H A; Cebula, H; Benmekhbi, M; Chenard, M P; Entz-Werle, N; Proust, F

    2016-12-01

    Diffuse intrinsic pontine gliomas (DIPG) constitute 10-15% of all brain tumors in the pediatric population; currently prognosis remains poor, with an overall survival of 7-14 months. Recently the indication of DIPG biopsy has been enlarged due to the development of molecular biology and various ongoing clinical and therapeutic trials. Classically a biopsy is performed using a stereotactic frame assisted procedure but the workflow may sometimes be heavy and more complex especially in children. In this study the authors present their experience with frameless robotic-guided biopsy of DIPG in a pediatric population. Retrospective study on a series of five consecutive pediatric patients harboring DIPG treated over a 4-year period. All patients underwent frameless robotic-guided biopsy via a transcerebellar approach. Among the 5 patients studied 3 were male and 2 female with a median age of 8.6 years [range 5 to 13 years]. Clinical presentation included ataxia, hemiparesis and cranial nerve palsy in all patients. MRI imaging of the lesion showed typical DIPG features (3 of them located in the pons) with hypo-intensity on T1 and hyper-intensity signal on T2 sequences and diffuse gadolinium enhancement. The mean procedure time was 56minutes (range 45 to 67minutes). No new postoperative neurological deficits were recorded. Histological diagnosis was achieved in all cases as follows: two anaplastic astrocytomas (grade III), two glioblastomas, and one diffuse astrocytoma (grade III). Frameless robotic assisted biopsy of DIPG in pediatric population is an easier, effective, safe and highly accurate method to achieve diagnosis. Copyright © 2016 Elsevier Masson SAS. All rights reserved.

  5. The benefits of using a vacuum-assisted socket system to improve balance and gait in elderly transtibial amputees.

    PubMed

    Samitier, C Beatriz; Guirao, Lluis; Costea, Maria; Camós, Josep M; Pleguezuelos, Eulogio

    2016-02-01

    Lower limb amputation leads to impaired balance, ambulation, and transfers. Proper fit of the prosthesis is a determining factor for successful ambulation. Vacuum-assisted socket systems extract air from the socket, which decreases pistoning and probability of soft-tissue injuries and increases proprioception and socket comfort. To investigate the effect of vacuum-assisted socket system on transtibial amputees' performance-based and perceived balance, transfers, and gait. Quasi-experimental before-and-after study. Subjects were initially assessed using their prosthesis with the regular socket and re-evaluated 4 weeks after fitting including the vacuum-assisted socket system. We evaluated the mobility grade using Medicare Functional Classification Level, Berg Balance Scale, Four Square Step Test, Timed Up and Go Test, the 6-Min Walk Test, the Locomotor Capabilities Index, Satisfaction with Prosthesis (SAT-PRO questionnaire), and Houghton Scale. A total of 16 unilateral transtibial dysvascular amputees, mean age 65.12 (standard deviation = 10.15) years. Using the vacuum-assisted socket system, the patients significantly improved in balance, gait, and transfers: scores of the Berg Balance Scale increased from 45.75 (standard deviation = 6.91) to 49.06 (standard deviation = 5.62) (p < 0.01), Four Square Step Test decreased from 18.18 (standard deviation = 3.84) s to 14.97 (3.9) s (p < 0.01), Timed Up and Go Test decreased from 14.3 (standard deviation = 3.29) s to 11.56 (2.46) s (p < 0.01). The distance walked in the 6-Min Walk Test increased from 288.53 (standard deviation = 59.57) m to 321.38 (standard deviation = 72.81) m (p < 0.01). Vacuum-assisted socket systems are useful for improving balance, gait, and transfers in over-50-year-old dysvascular transtibial amputees. This study gives more insight into the use of vacuum-assisted socket systems to improve elderly transtibial dysvascular amputees

  6. Real-Time 3D Fluoroscopy-Guided Large Core Needle Biopsy of Renal Masses: A Critical Early Evaluation According to the IDEAL Recommendations

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Kroeze, Stephanie G. C.; Huisman, Merel; Verkooijen, Helena M.

    2012-06-15

    Introduction: Three-dimensional (3D) real-time fluoroscopy cone beam CT is a promising new technique for image-guided biopsy of solid tumors. We evaluated the technical feasibility, diagnostic accuracy, and complications of this technique for guidance of large-core needle biopsy in patients with suspicious renal masses. Methods: Thirteen patients with 13 suspicious renal masses underwent large-core needle biopsy under 3D real-time fluoroscopy cone beam CT guidance. Imaging acquisition and subsequent 3D reconstruction was done by a mobile flat-panel detector (FD) C-arm system to plan the needle path. Large-core needle biopsies were taken by the interventional radiologist. Technical success, accuracy, and safety were evaluatedmore » according to the Innovation, Development, Exploration, Assessment, Long-term study (IDEAL) recommendations. Results: Median tumor size was 2.6 (range, 1.0-14.0) cm. In ten (77%) patients, the histological diagnosis corresponded to the imaging findings: five were malignancies, five benign lesions. Technical feasibility was 77% (10/13); in three patients biopsy results were inconclusive. The lesion size of these three patients was <2.5 cm. One patient developed a minor complication. Median follow-up was 16.0 (range, 6.4-19.8) months. Conclusions: 3D real-time fluoroscopy cone beam CT-guided biopsy of renal masses is feasible and safe. However, these first results suggest that diagnostic accuracy may be limited in patients with renal masses <2.5 cm.« less

  7. Automated tru-cut imaging-guided core needle biopsy of canine orbital neoplasia. A prospective feasibility study

    PubMed Central

    Cirla, A.; Rondena, M.; Bertolini, G.

    2016-01-01

    The purpose of this study was to evaluate the diagnostic value of imaging-guided core needle biopsy for canine orbital mass diagnosis. A second excisional biopsy obtained during surgery or necropsy was used as the reference standard. A prospective feasibility study was conducted in 23 canine orbital masses at a single centre. A complete ophthalmic examination was always followed by orbital ultrasound and computed tomography (CT) examination of the head. All masses were sampled with the patient still on the CT table using ultrasound (US) guided automatic tru-cut device. The most suitable sampling approach to the orbit was chosen each time based on the CT image analysis. One of the following different approaches was used: trans-orbital, trans-conjunctival or trans-masseteric. In all cases, the imaging-guided biopsy provided a sufficient amount of tissue for the histopathological diagnosis, which concurred with the biopsies obtained using the excisional technique. CT examination was essential for morphological diagnosis and provided detailed topographic information that allowed us to choose the safest orbital approach for the biopsy. US guided automatic tru-cut biopsy based on CT images, performed with patient still on the CT table, resulted in a minimally invasive, relatively easy, and accurate diagnostic procedure in dogs with orbital masses. PMID:27540512

  8. Automated tru-cut imaging-guided core needle biopsy of canine orbital neoplasia. A prospective feasibility study.

    PubMed

    Cirla, A; Rondena, M; Bertolini, G

    2016-01-01

    The purpose of this study was to evaluate the diagnostic value of imaging-guided core needle biopsy for canine orbital mass diagnosis. A second excisional biopsy obtained during surgery or necropsy was used as the reference standard. A prospective feasibility study was conducted in 23 canine orbital masses at a single centre. A complete ophthalmic examination was always followed by orbital ultrasound and computed tomography (CT) examination of the head. All masses were sampled with the patient still on the CT table using ultrasound (US) guided automatic tru-cut device. The most suitable sampling approach to the orbit was chosen each time based on the CT image analysis. One of the following different approaches was used: trans-orbital, trans-conjunctival or trans-masseteric. In all cases, the imaging-guided biopsy provided a sufficient amount of tissue for the histopathological diagnosis, which concurred with the biopsies obtained using the excisional technique. CT examination was essential for morphological diagnosis and provided detailed topographic information that allowed us to choose the safest orbital approach for the biopsy. US guided automatic tru-cut biopsy based on CT images, performed with patient still on the CT table, resulted in a minimally invasive, relatively easy, and accurate diagnostic procedure in dogs with orbital masses.

  9. Computer-assisted design of flux-cored wires

    NASA Astrophysics Data System (ADS)

    Dubtsov, Yu N.; Zorin, I. V.; Sokolov, G. N.; Antonov, A. A.; Artem'ev, A. A.; Lysak, V. I.

    2017-02-01

    The algorithm and description of the AlMe-WireLaB software for the computer-assisted design of flux-cored wires are introduced. The software functionality is illustrated with the selection of the components for the flux-cored wire, ensuring the acquisition of the deposited metal of the Fe-Cr-C-Mo-Ni-Ti-B system. It is demonstrated that the developed software enables the technologically reliable flux-cored wire to be designed for surfacing, resulting in a metal of an ordered composition.

  10. An HR-MAS MR Metabolomics Study on Breast Tissues Obtained with Core Needle Biopsy

    PubMed Central

    Cho, Nariya; Chang, Jung Min; Koo, Hye Ryoung; Yi, Ann; Kim, Hyeonjin; Park, Sunghyouk; Moon, Woo Kyung

    2011-01-01

    Background Much research has been devoted to the development of new breast cancer diagnostic measures, including those involving high-resolution magic angle spinning (HR-MAS) magnetic resonance (MR) spectroscopic techniques. Previous HR-MAS MR results have been obtained from post-surgery samples, which limits their direct clinical applicability. Methodology/Principal Findings In the present study, we performed HR-MAS MR spectroscopic studies on 31 breast tissue samples (13 cancer and 18 non-cancer) obtained by percutaneous core needle biopsy. We showed that cancer and non-cancer samples can be discriminated very well with Orthogonal Projections to Latent Structure-Discriminant Analysis (OPLS-DA) multivariate model on the MR spectra. A subsequent blind test showed 69% sensitivity and 94% specificity in the prediction of the cancer status. A spectral analysis showed that in cancer cells, taurine- and choline-containing compounds are elevated. Our approach, additionally, could predict the progesterone receptor statuses of the cancer patients. Conclusions/Significance HR-MAS MR metabolomics on intact breast tissues obtained by core needle biopsy may have a potential to be used as a complement to the current diagnostic and prognostic measures for breast cancers. PMID:22028780

  11. Integrated cooling-vacuum-assisted 1540-nm erbium:glass laser is effective in treating mild-to-moderate acne vulgaris.

    PubMed

    Politi, Y; Levi, A; Enk, C D; Lapidoth, M

    2015-12-01

    Acne treatment by a mid-infrared laser may be unsatisfactory due to deeply situated acne-affected sebaceous glands which serve as its target. Skin manipulation by vacuum and contact cooling may improve laser-skin interaction, reduce pain sensation, and increase overall safety and efficacy. To evaluate the safety and efficacy of acne treatment using an integrated cooling-vacuum-assisted 1540-nm erbium:glass laser, a prospective interventional study was conducted. It included 12 patients (seven men and five women) suffering from mild-to-moderate acne vulgaris. The device utilizes a mid-infrared 1540-nm laser (Alma Lasers Ltd. Caesarea, Israel), which is integrated with combined cooling-vacuum-assisted technology. An acne lesion is initially manipulated upon contact by a vacuum-cooling-assisted tip, followed by three to four stacked laser pulses (500-600 mJ, 4 mm spot size, and frequency of 2 Hz). Patients underwent four to six treatment sessions with a 2-week interval and were followed-up 1 and 3 months after the last treatment. Clinical photographs were taken by high-resolution digital camera before and after treatment. Clinical evaluation was performed by two independent dermatologists, and results were graded on a scale of 0 (exacerbation) to 4 (76-100 % improvement). Patients' and physicians' satisfaction was also recorded. Pain perception and adverse effects were evaluated as well. All patients demonstrated a moderate to significant improvement (average score of 3.6 and 2.0 within 1 and 3 months, respectively, following last treatment session). No side effects, besides a transient erythema, were observed. Cooling-vacuum-assisted 1540-nm laser is safe and effective for the treatment of acne vulgaris.

  12. Imaging-Guided Core-Needle Breast Biopsy: Impact of Meditation and Music Interventions on Patient Anxiety, Pain, and Fatigue.

    PubMed

    Soo, Mary Scott; Jarosz, Jennifer A; Wren, Anava A; Soo, Adrianne E; Mowery, Yvonne M; Johnson, Karen S; Yoon, Sora C; Kim, Connie; Hwang, E Shelley; Keefe, Francis J; Shelby, Rebecca A

    2016-05-01

    To evaluate the impact of guided meditation and music interventions on patient anxiety, pain, and fatigue during imaging-guided breast biopsy. After giving informed consent, 121 women needing percutaneous imaging-guided breast biopsy were randomized into three groups: (1) guided meditation; (2) music; (3) standard-care control group. During biopsy, the meditation and music groups listened to an audio-recorded, guided, loving-kindness meditation and relaxing music, respectively; the standard-care control group received supportive dialogue from the biopsy team. Immediately before and after biopsy, participants completed questionnaires measuring anxiety (State-Trait Anxiety Inventory Scale), biopsy pain (Brief Pain Inventory), and fatigue (modified Functional Assessment of Chronic Illness Therapy-Fatigue). After biopsy, participants completed questionnaires assessing radiologist-patient communication (modified Questionnaire on the Quality of Physician-Patient Interaction), demographics, and medical history. The meditation and music groups reported significantly greater anxiety reduction (P values < .05) and reduced fatigue after biopsy than the standard-care control group; the standard-care control group reported increased fatigue after biopsy. The meditation group additionally showed significantly lower pain during biopsy, compared with the music group (P = .03). No significant difference in patient-perceived quality of radiologist-patient communication was noted among groups. Listening to guided meditation significantly lowered biopsy pain during imaging-guided breast biopsy; meditation and music reduced patient anxiety and fatigue without compromising radiologist-patient communication. These simple, inexpensive interventions could improve women's experiences during core-needle breast biopsy. Copyright © 2016 American College of Radiology. Published by Elsevier Inc. All rights reserved.

  13. Prospective randomized trial comparing magnetic resonance imaging (MRI)-guided in-bore biopsy to MRI-ultrasound fusion and transrectal ultrasound-guided prostate biopsy in patients with prior negative biopsies.

    PubMed

    Arsov, Christian; Rabenalt, Robert; Blondin, Dirk; Quentin, Michael; Hiester, Andreas; Godehardt, Erhard; Gabbert, Helmut E; Becker, Nikolaus; Antoch, Gerald; Albers, Peter; Schimmöller, Lars

    2015-10-01

    A significant proportion of prostate cancers (PCas) are missed by conventional transrectal ultrasound-guided biopsy (TRUS-GB). It remains unclear whether the combined approach using targeted magnetic resonance imaging (MRI)-ultrasound fusion-guided biopsy (FUS-GB) and systematic TRUS-GB is superior to targeted MRI-guided in-bore biopsy (IB-GB) for PCa detection. To compare PCa detection between IB-GB alone and FUS-GB + TRUS-GB in patients with at least one negative TRUS-GB and prostate-specific antigen ≥4 ng/ml. Patients were prospectively randomized after multiparametric prostate MRI to IB-GB (arm A) or FUS-GB + TRUS-GB (arm B) from November 2011 to July 2014. The study was powered at 80% to demonstrate an overall PCa detection rate of ≥60% in arm B compared to 40% in arm A. Secondary endpoints were the distribution of highest Gleason scores, the rate of detection of significant PCa (Gleason ≥7), the number of biopsy cores to detect one (significant) PCa, the positivity rate for biopsy cores, and tumor involvement per biopsy core. The study was halted after interim analysis because the primary endpoint was not met. The trial enrolled 267 patients, of whom 210 were analyzed (106 randomized to arm A and 104 to arm B). PCa detection was 37% in arm A and 39% in arm B (95% confidence interval for difference, -16% to 11%; p=0.7). Detection rates for significant PCa (29% vs 32%; p=0.7) and the highest percentage tumor involvement per biopsy core (48% vs 42%; p=0.4) were similar between the arms. The mean number of cores was 5.6 versus 17 (p<0.001). A limitation is the limited number of patients because of early cessation of accrual. This trial failed to identify an important improvement in detection rate for the combined biopsy approach over MRI-targeted biopsy alone. A prospective comparison between MRI-targeted biopsy alone and systematic TRUS-GB is justified. Our randomized study showed similar prostate cancer detection rates between targeted prostate biopsy

  14. Percentage of Positive Biopsy Cores: A Better Risk Stratification Model for Prostate Cancer?

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Huang Jiayi; Vicini, Frank A.; Williams, Scott G.

    2012-07-15

    Purpose: To assess the prognostic value of the percentage of positive biopsy cores (PPC) and perineural invasion in predicting the clinical outcomes after radiotherapy (RT) for prostate cancer and to explore the possibilities to improve on existing risk-stratification models. Methods and Materials: Between 1993 and 2004, 1,056 patients with clinical Stage T1c-T3N0M0 prostate cancer, who had four or more biopsy cores sampled and complete biopsy core data available, were treated with external beam RT, with or without a high-dose-rate brachytherapy boost at William Beaumont Hospital. The median follow-up was 7.6 years. Multivariate Cox regression analysis was performed with PPC, Gleasonmore » score, pretreatment prostate-specific antigen, T stage, PNI, radiation dose, androgen deprivation, age, prostate-specific antigen frequency, and follow-up duration. A new risk stratification (PPC classification) was empirically devised to incorporate PPC and replace the T stage. Results: On multivariate Cox regression analysis, the PPC was an independent predictor of distant metastasis, cause-specific survival, and overall survival (all p < .05). A PPC >50% was associated with significantly greater distant metastasis (hazard ratio, 4.01; 95% confidence interval, 1.86-8.61), and its independent predictive value remained significant with or without androgen deprivation therapy (all p < .05). In contrast, PNI and T stage were only predictive for locoregional recurrence. Combining the PPC ({<=}50% vs. >50%) with National Comprehensive Cancer Network risk stratification demonstrated added prognostic value of distant metastasis for the intermediate-risk (hazard ratio, 5.44; 95% confidence interval, 1.78-16.6) and high-risk (hazard ratio, 4.39; 95% confidence interval, 1.70-11.3) groups, regardless of the use of androgen deprivation and high-dose RT (all p < .05). The proposed PPC classification appears to provide improved stratification of the clinical outcomes relative to the

  15. Ability of sextant biopsies to predict radical prostatectomy stage.

    PubMed

    Wills, M L; Sauvageot, J; Partin, A W; Gurganus, R; Epstein, J I

    1998-05-01

    There are few studies evaluating multiple variables on sextant biopsies with the intent to predict stage in radical prostatectomy specimens. We studied 113 sextant biopsies with corresponding totally submitted radical prostatectomy specimens. Variables evaluated on sextant biopsies included total length and percent of cancer; maximum length and percent of cancer on one core; location (apex, mid, base); bilaterality; Gleason grade; number of cores involved; serum prostate-specific antigen (PSA) level; and serum PSA density (PSAD). Radical prostatectomy stage was classified as organ versus non-organ confined. The following variables individually correlated with radical prostatectomy stage: total cancer measured in millimeters (P <0.0001) or percent (P <0.0005); biopsy Gleason score (P <0.0001); number of involved cores (P <0.0001); maximum cancer on one core measured in millimeters (P = 0.0001); maximum percent of cancer on one core (P = 0.01); bilaterality (P = 0.01); PSA level (P = 0.03), and PSAD (P = 0.001). The most predictive sets of two variables that correlated with stage included high Gleason score (P <0.0001) combined with numbers of cores involved (P = 0.002). When biopsies had Gleason scores of 6 or less, two or fewer positive cores, and serum PSA of 0 to 4 ng/mL, 89% were organ confined. When biopsies had Gleason scores of 6 or less with two unilaterally positive cores, 87% were organ confined. In biopsies with Gleason scores of 7 or more and more than one positive core, only 10% were organ confined. The most important predictors of stage by sextant needle biopsy evaluation are numbers of cores involved with carcinoma and high Gleason score. Bilaterality and serum PSA values improved prediction in two small subgroups. In 37% of our population we were able to predict with a greater than 87% probability the organ-confined versus non-organ-confined status.

  16. Occiput posterior fetal head position increases the risk of anal sphincter injury in vacuum-assisted deliveries.

    PubMed

    Wu, Jennifer M; Williams, Kathryn S; Hundley, Andrew F; Connolly, AnnaMarie; Visco, Anthony G

    2005-08-01

    The purpose of this study was to determine whether an occiput posterior (OP) fetal head position increases the risk for anal sphincter injury when compared with an occiput anterior (OA) position in vacuum-assisted deliveries. We conducted a retrospective cohort study of 393 vacuum-assisted singleton vaginal deliveries. Maternal demographics and obstetric and neonatal data were collected from an obstetric database and chart review. Within the OP group, 41.7% developed a third- or fourth-degree laceration compared with 22.0% in the OA group (OR 2.5, 95% CI 1.4-4.7). In a logistic regression model that controlled for BMI, race, nulliparity, length of second stage, episiotomy, birth weight, head circumference, and fetal head position, OP position was 4.0 times (95% CI 1.7-9.6) more likely to be associated with an anal sphincter injury than OA position. Among vacuum deliveries, an OP head position confers an incrementally increased risk for anal sphincter injury over an OA position.

  17. A novel semi-robotized device for high-precision 18F-FDG-guided breast cancer biopsy.

    PubMed

    Hellingman, D; Teixeira, S C; Donswijk, M L; Rijkhorst, E J; Moliner, L; Alamo, J; Loo, C E; Valdés Olmos, R A; Stokkel, M P M

    To assess the 3D geometric sampling accuracy of a new PET-guided system for breast cancer biopsy (BCB) from areas within the tumour with high 18 F-FDG uptake. In the context of the European Union project MammoCare, a prototype semi-robotic stereotactic prototype BCB-device was incorporated into a dedicated high resolution PET-detector for breast imaging. The system consists of 2 stacked rings, each containing 12 plane detectors, forming a dodecagon with a 186mm aperture for 3D reconstruction (1mm 3 voxel). A vacuum-assisted biopsy needle attached to a robot-controlled arm was used. To test the accuracy of needle placement, the needle tip was labelled with 18 F-FDG and positioned at 78 target coordinates distributed over a 35mm×24mm×28mm volume within the PET-detector field-of-view. At each position images were acquired from which the needle positioning accuracy was calculated. Additionally, phantom-based biopsy proofs, as well as MammoCare images of 5 breast cancer patients, were evaluated for the 3D automated locating of 18 F-FDG uptake areas within the tumour. Needle positioning tests revealed an average accuracy of 0.5mm (range 0-1mm), 0.6mm (range 0-2mm), and 0.4mm (range 0-2mm) for the x/y/z-axes, respectively. Furthermore, the MammoCare system was able to visualize and locate small (<10mm) regions with high 18 F-FDG uptake within the tumour suitable for PET-guided biopsy after being located by the 3D automated application. Accuracy testing demonstrated high-precision of this semi-automatic 3D PET-guided system for breast cancer core needle biopsy. Its clinical feasibility evaluation in breast cancer patients scheduled for neo-adjuvant chemotherapy will follow. Copyright © 2016 Elsevier España, S.L.U. y SEMNIM. All rights reserved.

  18. Longer biopsy cores do not increase prostate cancer detection rate: A large-scale cohort study refuting cut-off values indicated in the literature

    PubMed Central

    Yılmaz, Hasan; Yavuz, Ufuk; Üstüner, Murat; Çiftçi, Seyfettin; Yaşar, Hikmet; Müezzinoğlu, Bahar; Uslubaş, Ali Kemal; Dillioğlugil, Özdal

    2017-01-01

    Objective Only a few papers in the literature aimed to evaluate biopsy core lengths. Additionally, studies evaluated the core length with different approaches. We aimed to determine whether prostate cancer (PCa) detection is affected from core lengths according to three different approaches in a large standard cohort and compare our cut-off values with the published cut-offs. Material and methods We retrospectively analyzed 1,523 initial consecutive transrectal ultrasound-guided 12-core prostate biopsies. Biopsies were evaluated with respect to total core length (total length of each patients’ core) average core length (total core length divided by total number of cores in each patient), and mean core length (mean length of all cores pooled), and compared our cut-off values with the published cut-offs. The prostate volumes were categorized into four groups (<30, 30–59.99, 60–119.99, ≥120 cm3) and PCa detection rates in these categories were examined. Results PCa was found in 41.5% patients. There was no difference between benign and malignant mean core lengths of the pooled cores (p>0.05). Total core length and average core length were not significantly associated with PCa in multivariate logistic regression analyses (p>0.05). The core lengths (mean, average and total core lengths) increased (p<0.001) and PCa rates decreased (p<0.001) steadily with increasing prostate volume categories. PCa percentages decreased in all categories above the utilized cut-offs for mean (p>0.05), average (p<0.05), and total core lengths (p>0.05). Conclusion There was no difference between mean core lengths of benign and malignant cores. Total core length and average core length were not significantly associated with PCa. Contrary to the cut-offs used for mean and average core lengths in the published studies, PCa rates decrease as these core lengths increase. Larger studies are necessary for the determination and acceptance of accurate cut-offs. PMID:28861301

  19. Minimalist video-assisted thoracic surgery biopsy of mediastinal tumors.

    PubMed

    Tacconi, Federico; Rogliani, Paola; Cristino, Benedetto; Gilardi, Francesco; Palombi, Leonardo; Pompeo, Eugenio

    2016-12-01

    Mediastinal tumors often require surgical biopsy to achieve a precise and rapid diagnosis. However, subjects with mediastinal tumors may be unfit for general anesthesia, particularly when compression of major vessels or airways does occur. We tested the applicability in this setting of a minimalist (M) uniportal, video-assisted thoracic surgery (VATS) strategy carried out under locoregional anesthesia in awake patients (MVATS). We analyzed in a comparative fashion including propensity score matching, data from a prospectively collected database of patients who were offered surgical biopsy for mediastinal tumors through either MVATS or standard VATS. Tested outcome measures included feasibility, diagnostic yield, and morbidity. A total of 24 procedures were performed through MVATS. Diagnostic yield was 100%. Median hospital stay and time interval to oncologic treatment were 2 days (IQR, 2-3 days) and 7 days (IQR, 5.5-11.5 days), respectively. At overall comparison (MVATS, N=24 vs. VATS, N=23), there was a significant difference in both frequency and severity of postoperative complication as measured by Clavien-Dindo classification (P<0.006). In a propensity score matched comparison (8 patients per group), grade 3 or 4 complications requiring aggressive management were found only in the general anesthesia group. Global time spent in the operating room was shorter in the MVATS group (P=0.05). Time interval to oncological treatment was the same between groups. Other differences were also found in SIRS score (P=0.05) and PaO 2 /FiO 2 (P=0.04) thus suggesting better adaption to perioperative stress. MVATS biopsy appears to be a reliable tool to optimize diagnostic assessment in patients with mediastinal tumors. It can offer high diagnostic accuracy due to large tissue samples, while reducing morbidity rate compared to the same operation under general anesthesia. More robust evaluation is needed to define the appropriateness of MVATS in this specific clinical setting.

  20. Accuracy of Percutaneous Core Biopsy in the Diagnosis of Small Renal Masses (≤ 4.0 cm): A Meta-analysis.

    PubMed

    He, Qiqi; Wang, Hanzhang; Kenyon, Jonathan; Liu, Guiming; Yang, Li; Tian, Junqiang; Yue, Zhongjin; Wang, Zhiping

    2015-01-01

    To use meta-analysis to determine the accuracy of percutaneous core needle biopsy in the diagnosis of small renal masses (SMRs ≤ 4.0 cm). Studies were identified by searching PubMed, Embase, and the Cochrane Library database up to March 2013. Two of the authors independently assessed the study quality using QUADAS-2 tool and extracted data that met the inclusion criteria. The sensitivity, specificity, likelihood ratios, diagnostic odds ratio (DOR) and also summary receiver operating characteristic (SROC) curve were investigated and draw. Deek's funnel plot was used to evaluate the publication bias. A total of 9 studies with 788 patients (803 biopsies) were included. Failed biopsies without repeated or aborted from follow-up/surgery result were excluded (232 patients and 353 biopsies). For all cases, the pooled sensitivity was 94.0% (95% CI: 91.0%, 95.0%), the pooled positive likelihood was 22.57 (95 % CI: 9.20-55.34), the pooled negative likelihood was 0.09 (95 % CI: 0.06-0.13), the pooled DOR was 296.52(95 % CI: 99. 42-884.38). The area under the curve of SROC analysis was 0.959 ± 0.0254. Imaging-guided percutaneous core needle biopsy of small renal masses (SMRs ≤ 4.0 cm) is highly accurate to malignant tumor diagnosis with unknown metastatic status and could be offered to some patients after clinic judgment prior to surgical intervention consideration.

  1. Number of Biopsies in Diagnosing Pulmonary Nodules

    PubMed Central

    Wehrschuetz, M.; Wehrschuetz, E.; Portugaller, H. R.

    2010-01-01

    Purpose: To determine the number of specimens to be obtained from pulmonary lesions to get the highest possible accuracy in histological work-up. Materials and methods: A retrospective evaluation (January 1999 to April 2004) covered 260 patients with thoracic lesions who underwent computer tomography (CT)-guided core-cut biopsy in coaxial technique. All biopsies were performed utilizing a 19 gauge introducer needle and a 20 gauge core-cut biopsy needle. In all, 669 usable biopsies were taken (from 1–5 biopsies in each setting). The specimens were marked sequentially and each biopsy was worked up histologicaly. The biopsy results were correlated to histology after surgery, clinical follow-up or autopsy. The number of biopsies was determined that is necessary to achieve the highest possible accuracy in diagnosing pulmonary lesions. Results: In 591 of 669 biopsies (88.3%), there were correct positive results. The overall accuracy was 87.4%. In 193 of 260 (74.2%) patients, a suspected malignancy was confirmed. In 50 of 260 (19.2%) patients, a benign lesion was correctly diagnosed. Seventeen (6.5%) patients were lost to follow-up. The first, second and third biopsies had cumulative accuracies of 63.6%, 89.2% and 91.5%, respectively (P < 0.02). More biopsies did not show any higher impact on accuracy. Conclusion: For the highest possible accuracy in diagnosing pulmonary lesions by CT-guided core-cut biopsy, at least three usable specimens are recommended to be taken. PMID:21157523

  2. Bronchoscopic lung biopsy using noninvasive ventilatory support: case series and review of literature of NIV-assisted bronchoscopy.

    PubMed

    Agarwal, Ritesh; Khan, Ajmal; Aggarwal, Ashutosh N; Gupta, Dheeraj

    2012-11-01

    Fiberoptic bronchoscopy and lung biopsy are important diagnostic tools in patients with diffuse pulmonary infiltrates. However, these patients often have hypoxemic respiratory failure that makes this procedure hazardous. Noninvasive ventilation (NIV) has been shown to improve oxygenation in hypoxemic patients. To report the efficacy and safety of an innovative technique of NIV-assisted bronchoscopic lung biopsy in a small case-series of hypoxemic subjects with diffuse parenchymal infiltrates; also to systematically review the literature on NIV-assisted bronchoscopy. Subjects with bilateral diffuse parenchymal infiltrates and P(aO(2))/F(IO(2)) < 200 mm Hg underwent bronchoscopic lung biopsy under NIV support. NIV was initiated 10 min before the procedure and continued for 30 min after the procedure. The primary outcomes were performance of successful procedure and episodes of decline in S(pO(2)) < 90%. Secondary end points were the change in the respiratory and hemodynamic parameters during the procedure and occurrence of complications such as pneumothorax, hemorrhage, and endotracheal intubation. Six subjects, with a mean ± SD age of 44.5 ± 11.6 years, were included in the study. The median (interquartile range [IQR]) P(aO(2))/F(IO(2)) prior to lung biopsy was 164.5 mm Hg (146.3-176.3 mm Hg), and the median (IQR) inspiratory and expiratory positive airway pressures were 14 cm H(2)O (12-15 cm H(2)O) and 5 cm H(2)O. Fiberoptic bronchoscopy was well tolerated and all subjects maintained S(pO(2)) > 92% during the procedure. One subject required endotracheal intubation due to hemoptysis. A definite diagnosis was obtained in 5 of the 6 subjects. A repeat procedure was performed in one subject, which again yielded no diagnosis. No other periprocedural complications were encountered. NIV-assisted bronchoscopic lung biopsy is a novel method for obtaining diagnosis in hypoxemic patients with diffuse lung infiltrates. However, this approach should be reserved for centers

  3. Surface oxidation of GaN(0001): Nitrogen plasma-assisted cleaning for ultrahigh vacuum applications

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Gangopadhyay, Subhashis; Schmidt, Thomas, E-mail: tschmidt@ifp.uni-bremen.de; Kruse, Carsten

    The cleaning of metal-organic vapor-phase epitaxial GaN(0001) template layers grown on sapphire has been investigated. Different procedures, performed under ultrahigh vacuum conditions, including degassing and exposure to active nitrogen from a radio frequency nitrogen plasma source have been compared. For this purpose, x-ray photoelectron spectroscopy, reflection high-energy electron diffraction, and scanning tunneling microscopy have been employed in order to assess chemical as well as structural and morphological surface properties. Initial degassing at 600 °C under ultrahigh vacuum conditions only partially eliminates the surface contaminants. In contrast to plasma assisted nitrogen cleaning at temperatures as low as 300 °C, active-nitrogen exposure at temperaturesmore » as high as 700 °C removes the majority of oxide species from the surface. However, extended high-temperature active-nitrogen cleaning leads to severe surface roughening. Optimum results regarding both the removal of surface oxides as well as the surface structural and morphological quality have been achieved for a combination of initial low-temperature plasma-assisted cleaning, followed by a rapid nitrogen plasma-assisted cleaning at high temperature.« less

  4. A fully actuated robotic assistant for MRI-guided prostate biopsy and brachytherapy

    NASA Astrophysics Data System (ADS)

    Li, Gang; Su, Hao; Shang, Weijian; Tokuda, Junichi; Hata, Nobuhiko; Tempany, Clare M.; Fischer, Gregory S.

    2013-03-01

    Intra-operative medical imaging enables incorporation of human experience and intelligence in a controlled, closed-loop fashion. Magnetic resonance imaging (MRI) is an ideal modality for surgical guidance of diagnostic and therapeutic procedures, with its ability to perform high resolution, real-time, high soft tissue contrast imaging without ionizing radiation. However, for most current image-guided approaches only static pre-operative images are accessible for guidance, which are unable to provide updated information during a surgical procedure. The high magnetic field, electrical interference, and limited access of closed-bore MRI render great challenges to developing robotic systems that can perform inside a diagnostic high-field MRI while obtaining interactively updated MR images. To overcome these limitations, we are developing a piezoelectrically actuated robotic assistant for actuated percutaneous prostate interventions under real-time MRI guidance. Utilizing a modular design, the system enables coherent and straight forward workflow for various percutaneous interventions, including prostate biopsy sampling and brachytherapy seed placement, using various needle driver configurations. The unified workflow compromises: 1) system hardware and software initialization, 2) fiducial frame registration, 3) target selection and motion planning, 4) moving to the target and performing the intervention (e.g. taking a biopsy sample) under live imaging, and 5) visualization and verification. Phantom experiments of prostate biopsy and brachytherapy were executed under MRI-guidance to evaluate the feasibility of the workflow. The robot successfully performed fully actuated biopsy sampling and delivery of simulated brachytherapy seeds under live MR imaging, as well as precise delivery of a prostate brachytherapy seed distribution with an RMS accuracy of 0.98mm.

  5. Granulomatous mastitis: changing clinical and imaging features with image-guided biopsy correlation.

    PubMed

    Handa, Priyanka; Leibman, A Jill; Sun, Derek; Abadi, Maria; Goldberg, Aryeh

    2014-10-01

    To review clinical presentation, revisit patient demographics and imaging findings in granulomatous mastitis and determine the optimal biopsy method for diagnosis. A retrospective study was performed to review the clinical presentation, imaging findings and biopsy methods in patients with granulomatous mastitis. Twenty-seven patients with pathology-proven granulomatous mastitis were included. The average age at presentation was 38.0 years (range, 21-73 years). Seven patients were between 48 and 73 years old. Twenty-four patients presented with symptoms and three patients were asymptomatic. Nineteen patients were imaged with mammography demonstrating mammographically occult lesions as the predominant finding. Twenty-six patients were imaged with ultrasound and the most common finding was a mass lesion. Pathological diagnosis was made by image-guided biopsy in 44 % of patients. The imaging features of granulomatous mastitis on mammography are infrequently described. Our study demonstrates that granulomatous mastitis can occur in postmenopausal or asymptomatic patients, although previously reported exclusively in young women with palpable findings. Presentation on mammography as calcifications requiring mammographically guided vacuum-assisted biopsy has not been previously described. The diagnosis of granulomatous mastitis can easily be made by image-guided biopsy and surgical excision should be reserved for definitive treatment. • Characterizes radiographic appearance of granulomatous mastitis in postmenopausal or asymptomatic patients. • Granulomatous mastitis can present exclusively as calcifications on mammography. • The diagnosis of granulomatous mastitis is made by image-guided biopsy techniques.

  6. Vacuum-assisted closure as a surgical assistant in life-threatening necrotizing fasciitis in children

    PubMed Central

    Al-Subhi, FS; Zuker, RM; Cole, WG

    2010-01-01

    Necrotizing fasciitis is a severe soft tissue infection that can involve skin, subcutaneous fat, fascia and muscle. It can result in devastating sequelae including tissue necrosis, sepsis, toxic shock syndrome, cardiopulmonary collapse and death. To control rapidly spreading necrosis, early diagnosis and aggressive surgical treatment with extensive radical debridement of the affected areas is necessary, as well as systemic administration of broad-spectrum antimicrobials and, very often, intensive care support. The subatmospheric negative pressure dressing has been previously used in acute and complex wounds management. The concept of using vacuum-assisted closure dressing as another management component is presented in the current article. PMID:22131841

  7. Cost comparison between ultrasound-guided 14-g large core breast biopsy and open surgical biopsy: an analysis for Austria.

    PubMed

    Gruber, R; Walter, E; Helbich, T H

    2010-06-01

    To examine the budget impact of ultrasound-guided 14-g large core breast biopsy (US-guided LCBB) by comparing the costs of US-guided LCBB and open surgical biopsy (OSB); to calculate the cost savings attributable to US-guided LCBB; and to assess the frequency with which US-guided LCBB obviates the need for an OSB. In a retrospective study, we reviewed 399 suspicious breast lesions on which US-guided LCBB and OSB or, in cases of benign histology, clinical follow-up, were performed. Cost savings were calculated using nationally allowed flat rates (A-drg) and patient charges. Costs were measured from both, a hospital and a socioeconomic perspective. Deterministic sensitivity analyses were simulated to assess the extent of achievable cost savings. Overall cost savings for US-guided LCBB over OSB were euro 977 (euro 2,337/euro 3,314) per case from a hospital perspective, resulting in a total cost decrease of 30% for the diagnosis of suspicious breast lesions. From a socioeconomic perspective, cost savings were euro 1,542 (euro 2,600/euro 4,142) per case, resulting in a 37% reduction in biopsy cost. US-guided LCBB obviated the need for a surgical procedure in 240 (60%) of 399 women. In all four sensitivity analyses, costs of US-guided LCBB remained lower than that of OSB. From an economic perspective, US-guided LCBB is highly recommended for the diagnosis of suspicious breast lesions, as this procedure reduces the cost of diagnosis substantially. In Austria, annual cost savings would be euro 18.5 million. Copyright (c) 2009 Elsevier Ireland Ltd. All rights reserved.

  8. Health Care Assistant Core. Instructor Manual.

    ERIC Educational Resources Information Center

    Feilner, Veronica; Robling, Jeannine

    This document contains the core curriculum for a basic high school course for health care assistants. It is designed as a 1-semester course of study, after which students can take a course in an emphasis area, such as veterinary, nursing, pharmacology, or physical therapy, in which they learn skills for specific entry-level jobs. The curriculum…

  9. Does Core Length Taken per cc of Prostate Volume in Prostate Biopsy Affect the Diagnosis of Prostate Cancer?

    PubMed

    Deliktas, Hasan; Sahin, Hayrettin; Cetinkaya, Mehmet; Dere, Yelda; Erdogan, Omer; Baldemir, Ercan

    2016-08-01

    The aim of this study was to determine the minimal core length to be taken per cc of prostate volume for an effective prostate biopsy. A retrospective analysis was performed on the records of 379 patients who underwent a first prostate biopsy with 12 to 16 cores under transrectal ultrasound guidance between September 2012 and April 2015. For each patient, the core length per cc of the prostate and the percentage of sampled prostate volume were calculated, and these values were compared between the patients with and without prostate cancer. A total of 348 patients were included in the study. Cancer was determined in 26.4% of patients. The mean core length taken per cc of prostate and the percentage of sampled prostate volume were determined to be 3.40 ± 0.15 mm/cc (0.26%; range, 0.08-0.63 cc) in patients with cancer and 2.75 ± 0.08 mm/cc (0.20%; range, 0.04-0.66 cc) in patients without cancer (P = .000 and P = .000), respectively. Core length taken per cc of prostate of > 3.31 mm/cc was found to be related to an increase in the rates of prostate cancer diagnosis (odds ratio, 2.84; 95% confidence interval, 1.68-4.78). The rate of cancer determination for core length taken per cc of prostate of < 3.31 mm/cc was 19.9% and of > 3.31 mm/cc, 41.1%. Core length taken per cc of prostate and the percentage of sampled prostate volume are important morphometric parameters in the determination of prostate cancer. The results of study suggest a core length per cc of the prostate of > 3.31 mm/cc as a cutoff value for quality assurance. Copyright © 2016 Elsevier Inc. All rights reserved.

  10. Prospective cohort study of a new vacuum delivery device to assist with complicated labour in low-resource settings.

    PubMed

    Khan, Mishal; Hashmani, Farah Naz; Ahmed, Sajjad; Ahmed, Owais; Asim, Shabnam S; Wajahat, Yasmin; Sobani, Shoaib; Syed, Shershah; Qazi, Fahad

    2015-02-01

    Currently available vacuum devices used to assist women undergoing complicated labour are unsuitable for use in low-resource settings. The objective of this study was to evaluate the safety and feasibility of a new low-cost vacuum device, named Koohi Goth Vacuum Delivery System (KGVDS), designed for use in low-resource settings. A hospital-based, multicentre, prospective cohort study with no control group was conducted in Karachi, Pakistan. After training, KGVDS devices were made available for use by labour room staff at their discretion when instrumental delivery was indicated. Women to whom KGVDS was applied were followed from the start of labour until discharge. Feasibility was assessed in terms of successful expulsion of the foetal head following application of KGVDS and ease of use ratings. Safety was assessed by observing maternal and newborn post-delivery outcomes prior to discharge. Koohi Goth Vacuum Delivery System was applied to 137 women requiring instrumental delivery, of whom 111 (81%; 95% CI = 74-88%) successfully expelled the foetal head assisted by KGVDS and 103 (75%) stated that they would agree to use KGVDS again. There were no serious maternal or neonatal injuries or infections related to KGVDS use. The mean score for 'ease of use' given by doctors and midwives using the device was 8 of 10. Koohi Goth Vacuum Delivery System was feasible and safe to use for assisting complicated deliveries in low-resource hospitals in this initial evaluation. Our results indicate that this new device may have the potential to improve birth outcomes in settings where most mortality occurs and that further evaluations should be conducted. © 2014 John Wiley & Sons Ltd.

  11. Magnetic resonance imaging-guided core needle breast biopsies resulting in high-risk histopathologic findings: upstage frequency and lesion characteristics.

    PubMed

    Weinfurtner, R Jared; Patel, Bhavika; Laronga, Christine; Lee, Marie C; Falcon, Shannon L; Mooney, Blaise P; Yue, Binglin; Drukteinis, Jennifer S

    2015-06-01

    Analysis of magnetic resonance imaging-guided breast biopsies yielding high-risk histopathologic features at a single institution found an overall upstage rate to malignancy of 14% at surgical excision. All upstaged lesions were associated with atypical ductal hyperplasia. Flat epithelial atypia and atypical lobular hyperplasia alone or with lobular carcinoma in situ were not associated with an upstage to malignancy. The purpose of the present study w as to determine the malignancy upstage rates and imaging features of high-risk histopathologic findings resulting from magnetic resonance imaging (MRI)-guided core needle breast biopsies. These features include atypical ductal hyperplasia (ADH), atypical lobular hyperplasia (ALH), flat epithelial atypia (FEA), and lobular carcinoma in situ (LCIS). A retrospective medical record review was performed on all MRI-guided core needle breast biopsies at a single institution from June 1, 2007 to December 1, 2013 to select biopsies yielding high-risk histopathologic findings. The patient demographics, MRI lesion characteristics, and histopathologic features at biopsy and surgical excision were analyzed. A total of 257 MRI-guided biopsies had been performed, and 50 yielded high-risk histopathologic features (19%). Biopsy site and surgical excision site correlation was confirmed in 29 of 50 cases. Four of 29 lesions (14%) were upstaged: 1 case to invasive ductal carcinoma and 3 cases to ductal carcinoma in situ. ADH alone had an overall upstage rate of 7% (1 of 14), mixed ADH/ALH a rate of 75% (3 of 4), ALH alone or with LCIS a rate of 0% (0 of 7), and FEA a rate of 0% (0 of 4). Only mixed ADH/ALH had a statistically significant upstage rate to malignancy compared with the other high-risk histopathologic subtypes combined. No specific imaging characteristics on MRI were associated with an upstage to malignancy on the statistical analysis. MRI-guided breast biopsies yielding high-risk histopathologic features were associated with

  12. Cytokeratin 5 and estrogen receptor immunohistochemistry as a useful adjunct in identifying atypical papillary lesions on breast needle core biopsy.

    PubMed

    Grin, Andrea; O'Malley, Frances P; Mulligan, Anna Marie

    2009-11-01

    The presence of atypical or usual epithelial proliferations within papillary breast lesions complicates their interpretation on core biopsy. We evaluated the combination of estrogen receptor (ER) and cytokeratin 5 (CK5) as an aid in the distinction of usual duct hyperplasia from atypical proliferations in this setting. Core biopsies from 185 papillary lesions were reviewed and of these, 82 cases were selected for immunohistochemical study based on the presence of an epithelial proliferation between the fibrovascular cores. Fifty-two cases were used as the test set and 30 cases, with subsequent surgical excision, were used as the validation set. The epithelial proliferation was evaluated for staining intensity and percentage of positive cells using CK5 and ER. Expression of both CK5 and ER was significantly different in nonatypical lesions when compared with atypical lesions (P<0.0001). Nonatypical lesions typically showed an ER-low/CK5-high profile and atypical lesions showed an ER-high/CK5-low profile with ER-high expression defined as diffuse strong staining in >90% of cells. CK5-high expression was defined as a mosaic pattern of staining in >20% of cells and CK5-low as absent or staining in <20% of cells. On the basis of their staining profile, 29 of the 30 validation cases were correctly classified using the excision specimen as the gold standard. Patterns and extent of ER and CK5 staining, when used together, are valuable adjunct stains to differentiate usual duct hyperplasia from atypical proliferations within papillary lesions on core biopsy.

  13. Percentage of Cancer Volume in Biopsy Cores Is Prognostic for Prostate Cancer Death and Overall Survival in Patients Treated With Dose-Escalated External Beam Radiotherapy

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Vance, Sean M.; Stenmark, Matthew H.; Blas, Kevin

    2012-07-01

    Purpose: To investigate the prognostic utility of the percentage of cancer volume (PCV) in needle biopsy specimens for prostate cancer patients treated with dose-escalated external beam radiotherapy. Methods and Materials: The outcomes were analyzed for 599 men treated for localized prostate cancer with external beam radiotherapy to a minimal planning target volume dose of 75 Gy (range, 75-79.2). We assessed the effect of PCV and the pretreatment and treatment-related factors on the freedom from biochemical failure, freedom from metastasis, cause-specific survival, and overall survival. Results: The median number of biopsy cores was 7 (interquartile range, 6-12), median PCV was 10%more » (interquartile range, 2.5-25%), and median follow-up was 62 months. The PCV correlated with the National Comprehensive Cancer Network risk group and individual risk features, including T stage, prostate-specific antigen level, Gleason score, and percentage of positive biopsy cores. On log-rank analysis, the PCV stratified by quartile was prognostic for all endpoints, including overall survival. In addition, the PCV was a stronger prognostic factor than the percentage of positive biopsy cores when the two metrics were analyzed together. On multivariate analysis, the PCV predicted a worse outcome for all endpoints, including freedom from biochemical failure, (hazard ratio, 1.9; p = .0035), freedom from metastasis (hazard ratio, 1.7, p = .09), cause-specific survival (hazard ratio, 3.9, p = .014), and overall survival (hazard ratio, 1.8, p = .02). Conclusions: For patients treated with dose-escalated external beam radiotherapy, the volume of cancer in the biopsy specimen adds prognostic value for clinically relevant endpoints, particularly in intermediate- and high-risk patients. Although the PCV determination is more arduous than the percentage of positive biopsy cores, it provides superior risk stratification.« less

  14. Study on design and cutting parameters of rotating needles for core biopsy.

    PubMed

    Giovannini, Marco; Ren, Huaqing; Cao, Jian; Ehmann, Kornel

    2018-06-15

    Core needle biopsies are widely adopted medical procedures that consist in the removal of biological tissue to better identify a lesion or an abnormality observed through a physical exam or a radiology scan. These procedures can provide significantly more information than most medical tests and they are usually performed on bone lesions, breast masses, lymph nodes and the prostate. The quality of the samples mainly depends on the forces exerted by the needle during the cutting process. The reduction of these forces is critical to extract high-quality tissue samples. The most critical factors that affect the cutting forces are the geometry of the needle tip and its motion while it is penetrating the tissue. However, optimal needle tip configurations and cutting parameters are not well established for rotating insertions. In this paper, the geometry and cutting forces of hollow needles are investigated. The fundamental goal of this study is to provide a series of guidelines for clinicians and surgeons to properly select the optimal tip geometries and speeds. Analytical models related to the cutting angles of several needle tip designs are presented and compared. Several needle tip geometries were manufactured from a 14-gauge cannula, commonly adopted during breast biopsies. The needles were then tested at different speeds and on different phantom tissues. According to these experimental measurements recommendations were formulated for rotating needle insertions. The findings of this study can be applied and extended to several biopsy procedures in which a cannula is used to extract tissue samples. Copyright © 2018 Elsevier Ltd. All rights reserved.

  15. Vacuum-assisted wound closure and mesh-mediated fascial traction for open abdomen therapy - a systematic review.

    PubMed

    Acosta, Stefan; Björck, Martin; Petersson, Ulf

    2017-01-01

    The aim of this paper was to review the literature on vacuum-assisted wound closure and mesh-mediated fascial traction (VAWCM) in open abdomen therapy. It was designed as systematic review of observational studies. A Pub Med, EMBASE and Cochrane search from 2007/01-2016/07 was performed combining the Medical Subject Headings "vacuum", "mesh-mediated fascial traction", "temporary abdominal closure", "delayed abdominal closure", "open abdomen", "abdominal compartment syndrome", "negative pressure wound therapy" or "vacuum assisted wound closure". Eleven original studies were found including patients numbering from 7 to 111. Six studies were prospective and five were retrospective. Nine studies were on mixed surgical (n = 9), vascular (n = 6) and trauma (n = 6) patients, while two were exclusively on vascular patients. The primary fascial closure rate per protocol varied from 80-100%. The time to closure of the open abdomen varied between 9-32 days. The entero-atmospheric fistula rate varied from 0-10.0%. The in-hospital survival rate varied from 57-100%. In the largest prospective study, the incisional hernia rate among survivors at 63 months of median follow-up was 54% (27/50), and 16 (33%) repairs out of 48 incisional hernias were performed throughout the study period. The study patients reported lower short form health survey (SF-36) scores than the mean reference population, mainly dependent on the prevalence of major co-morbidities. There was no difference in SF-36 scores or a modified ventral hernia pain questionnaire (VHPQ) at 5 years of follow up between those with versus those without incisional hernias. A high primary fascial closure rate can be achieved with the vacuum-assisted wound closure and meshmediated fascial traction technique in elderly, mainly non-trauma patients, in need of prolonged open abdomen therapy.

  16. Matrix Assisted Ionization Vacuum (MAIV), a New Ionization Method for Biological Materials Analysis Using Mass Spectrometry*

    PubMed Central

    Inutan, Ellen D.; Trimpin, Sarah

    2013-01-01

    The introduction of electrospray ionization (ESI) and matrix-assisted laser desorption/ionization (MALDI) for the mass spectrometric analysis of peptides and proteins had a dramatic impact on biological science. We now report that a wide variety of compounds, including peptides, proteins, and protein complexes, are transported directly from a solid-state small molecule matrix to gas-phase ions when placed into the vacuum of a mass spectrometer without the use of high voltage, a laser, or added heat. This ionization process produces ions having charge states similar to ESI, making the method applicable for high performance mass spectrometers designed for atmospheric pressure ionization. We demonstrate highly sensitive ionization using intermediate pressure MALDI and modified ESI sources. This matrix and vacuum assisted soft ionization method is suitable for the direct surface analysis of biological materials, including tissue, via mass spectrometry. PMID:23242551

  17. Nearly Seamless Vacuum-Insulated Boxes

    NASA Technical Reports Server (NTRS)

    Stepanian, Christopher J.; Ou, Danny; Hu, Xiangjun

    2010-01-01

    A design concept, and a fabrication process that would implement the design concept, have been proposed for nearly seamless vacuum-insulated boxes that could be the main structural components of a variety of controlled-temperature containers, including common household refrigerators and insulating containers for shipping foods. In a typical case, a vacuum-insulated box would be shaped like a rectangular parallelepiped conventional refrigerator box having five fully closed sides and a hinged door on the sixth side. Although it is possible to construct the five-closed-side portion of the box as an assembly of five unitary vacuum-insulated panels, it is not desirable to do so because the relatively high thermal conductances of the seams between the panels would contribute significant amounts of heat leakage, relative to the leakage through the panels themselves. In contrast, the proposal would make it possible to reduce heat leakage by constructing the five-closed-side portion of the box plus the stationary portion (if any) of the sixth side as a single, seamless unit; the only remaining seam would be the edge seal around the door. The basic cross-sectional configuration of each side of a vacuum-insulated box according to the proposal would be that of a conventional vacuum-insulated panel: a low-density, porous core material filling a partially evacuated space between face sheets. However, neither the face sheets nor the core would be conventional. The face sheets would be opposite sides of a vacuum bag. The core material would be a flexible polymer-modified silica aerogel of the type described in Silica/Polymer and Silica/Polymer/Fiber Composite Aero - gels (MSC-23736) in this issue of NASA Tech Briefs. As noted in that article, the stiffness of this core material against compression is greater than that of prior aerogels. This is an important advantage because it translates to greater retention of thickness and, hence, of insulation performance when pressure is

  18. Is it possible to predict low-volume and insignificant prostate cancer by core needle biopsies?

    PubMed

    Berg, Kasper Drimer; Toft, Birgitte Grønkaer; Røder, Martin Andreas; Brasso, Klaus; Vainer, Ben; Iversen, Peter

    2013-04-01

    In an attempt to minimize overtreatment of localized prostate cancer (PCa) active surveillance (AS) and minor invasive procedures have received increased attention. We investigated the accuracy of pre-operative findings in defining insignificant disease and distinguishing between unilateral/unifocal and bilateral/multifocal PCa. One-hundred and sixty patients undergoing radical prostatectomy were included. Histology reports from the biopsies and matching prostatectomies were compared. Three definitions of insignificant cancer were used: InsigE: tumour volume ≤0.5 mL; InsigW: tumour volume ≤1.3 mL; InsigM: tumour ≤5% of total prostate volume and prostate-specific antigen (PSA) ≤10 ng/mL. In all definitions, Gleason score (GS) was ≤6 and the tumour was organ confined. Biopsies alone performed poorly as a predictor of unifocal and unilateral cancer in the prostatectomy specimens with positive predictive values of 17.8% and 18.9% respectively. Inclusion of other clinical and biochemical parameters did not significantly increase the predictive value. However, the combination of GS ≤ 6, PSA ≤ 10 ng/mL and unifocal or unilateral cancer in biopsy cores resulted in a positive predictive value of 61.1%, 38.9% and 12.0%, respectively, for identifying InsigM, InsigW and InsigE in the prostate specimen. Conclusively, routine prostate biopsies cannot predict unifocal and unilateral PCa, and must be regarded insufficient to select patients for focal therapy. Although candidates for AS may be identified using standard biopsies, a considerable fraction of patients will be understaged. There is a need for more precise diagnostic tools to assess intraprostatic tumour growth. © 2012 The Authors APMIS © 2012 APMIS.

  19. Utility of core biopsy with concurrent ROSE FNA in the diagnosis of pancreatic tumor-does the biopsy add any diagnostic benefit?

    PubMed

    Yan, Lei; Ikemura, Kenji; Park, Ji-Weon

    2018-02-01

    Endoscopic ultrasound-guided fine-needle aspiration (EUS-FNA) and endoscopic ultrasound-guided core-needle biopsy (EUS-CNB) are widely used for diagnosis of pancreatic tumors. The aim of our study was to compare the diagnostic performance of ROSE EUS-FNA and EUS-CNB for diagnosis of pancreatic malignancy during the same EUS. Patients who underwent both FNA and CNB during the same EUS for pancreatic solid lesion were reviewed retrospectively. Sample adequacy, diagnostic yield (defined as percentage of definitive diagnosis), sensitivity and specificity for malignancy were compared between FNA and CNB. A total of 48 patients with solid pancreatic lesions were evaluated. The proportions of adequate samples were 48/48 (100%) for FNA and 45/48 (93.7%) for core biopsy (P = .24). The diagnostic yield was 42/48 (87.5%) and 33/48 (68.7%) for FNA and CNB respectively (P = .046). The incremental increase in diagnostic yield by combining both methods was 2/48 (4%). The diagnostic yield for malignancy was 30/32 (93.7%) for FNA and 23/32 (71.8%) for CNB (P = .043). The sensitivity for the diagnosis of malignancy for FNA and CNB were 90.6% and 69%, respectively (P = .045). The specificity was 100% for both methods. The sensitivity for diagnosing malignancy increased to 93.8% when the two methods were combined. The difference in diagnostic yield was not associated with lesion size or location. EUS-guided FNA is a superior method of assessing solid pancreatic lesion and pancreatic malignancy with better diagnostic yield and higher sensitivity than EUS-CNB. © 2017 Wiley Periodicals, Inc.

  20. Percutaneous CT-guided biopsy of the spine: results of 430 biopsies

    PubMed Central

    Rimondi, Eugenio; Errani, Costantino; Bianchi, Giuseppe; Casadei, Roberto; Alberghini, Marco; Malaguti, Maria Cristina; Rossi, Giuseppe; Durante, Stefano; Mercuri, Mario

    2008-01-01

    Biopsies of lesions in the spine are often challenging procedures with significant risk of complications. CT-guided needle biopsies could lower these risks but uncertainties still exist about the diagnostic accuracy. Aim of this retrospective study was to evaluate the diagnostic accuracy of CT-guided needle biopsies for bone lesions of the spine. We retrieved the results of 430 core needle biopsies carried out over the past fifteen years at the authors’ institute and examined the results obtained. Of the 430 biopsies performed, in 401 cases the right diagnosis was made with the first CT-guided needle biopsy (93.3% accuracy rate). Highest accuracy rates were obtained in primary and secondary malignant lesions. Most false negative results were found in cervical lesions and in benign, pseudotumoral, inflammatory, and systemic pathologies. There were only 9 complications (5 transient paresis, 4 haematomas that resolved spontaneously) that had no influence on the treatment strategy, nor on the patient’s outcome. In conclusion we can assert that this technique is reliable and safe and should be considered the gold standard in biopsies of the spine. PMID:18463900

  1. Evolving biopsy techniques for the diagnosis of neuroblastoma in children.

    PubMed

    Campagna, Giovanni; Rosenfeld, Eric; Foster, Jennifer; Vasudevan, Sanjeev; Nuchtern, Jed; Kim, Eugene; Commander, Sarah; Naik-Mathuria, Bindi

    2018-04-14

    To compare the adequacy and safety of percutaneous core needle biopsy and surgical wedge biopsy of neuroblastoma in children. A retrospective review of patients who underwent biopsy for intermediate- or high-risk neuroblastoma at our institution between 2011 and 2015 was performed (recent cohort). Procedure details and outcomes were collected and analyzed using descriptive statistics and Wilcoxon rank tests; P < 0.05 was considered significant. Published data from 2002 to 2010 were compared (historic cohort). Since 2011, percutaneous, ultrasound-guided, core needle biopsy has been more commonly utilized (47% (16/34) recent vs. 25% (7/28) historic; P = 0.07), and the number of core needle samples increased from median 7 (historic) to 25 (recent). Complications decreased (21% (7/34) recent vs. 64% (18/28) historic; P < 0.01). Biopsy adequacy in the recent cohort was similar (94% percutaneous vs. 89% surgical; P = 1.00), which is improved from the historic cohort (71% percutaneous vs. 100% surgical; P = 0.06). Larger tumors were more likely to have a percutaneous biopsy (82 ± 37 cm percutaneous vs. 47 ± 29 cm surgical; P = 0.04). When multiple cores are obtained, percutaneous core needle biopsy is adequate for complete tissue diagnosis of neuroblastoma and can be safely performed. This can be considered as an alternative to open surgical biopsy. Treatment Study. III. Copyright © 2018 Elsevier Inc. All rights reserved.

  2. Feasibility of computed tomography-guided core needle biopsy in producing state-of-the-art clinical management in Chinese lung cancer.

    PubMed

    Chen, Hua-Jun; Yang, Jin-Ji; Fang, Liang-Yi; Huang, Min-Min; Yan, Hong-Hong; Zhang, Xu-Chao; Xu, Chong-Rui; Wu, Yi-Long

    2014-03-01

    A satisfactory biopsy determines the state-of-the-art management of lung cancer in this era of personalized medicine. This study aimed to investigate the suitability and efficacy of computed tomography (CT)-guided core needle biopsy in clinical management. A cohort of 353 patients with clinically suspected lung cancer was enrolled in the study. Patient factors and biopsy variables were recorded. Epidermal growth factor receptor (EGFR) gene mutations and echinoderm microtubule-associated protein-like 4 (EML4)-anaplastic lymphoma kinase (ALK) rearrangement were detected in tumor specimens. Adequacy of biopsic obtainment for clinical trial screening and tissue bank establishment were reviewed. Overall diagnostic accuracy of malignancy achieved 98.5%. The median biopsy time of the cohort was 20 minutes. In patients with non-small cell lung cancer (NSCLC), 99.3% (287/289) were diagnosed as specific histologic subtypes, and two patients (0.7%) were determined as NSCLC not otherwise specified (NOS). EGFR mutations were analyzed in 81.7% (236/289) of patients with NSCLC, and 98.7% (233/236) showed conclusive results. EML4-ALK gene fusion was tested in 43.9% (127/289) of NSCLC patients, and 98.4% (125/127) showed conclusive results: 6.4% (8/125) of those had gene fusion. Ninety-six NSCLC patients participated in clinical trial screening and provided mandatory tumor slides for molecular profiling. Pathological evaluation was fulfilled in 90 patients (93.8%); 99.4% (320/322) of patients with malignancy provided extra tissue for the establishment of a tumor bank. CT-guided core needle biopsy provided optimal clinical management in this era of translational medicine. The biopsic modality should be prioritized in selected lung cancer patients.

  3. Non-malignant pathological results on transthoracic CT guided core-needle biopsy: when is benign really benign?

    PubMed

    Rui, Y; Han, M; Zhou, W; He, Q; Li, H; Li, P; Zhang, F; Shi, Y; Su, X

    2018-06-06

    To determine true negatives and characterise the variables associated with false-negative results when interpreting non-malignant results of computed tomography (CT)-guided lung biopsy. Nine hundred and fifty patients with initial non-malignant findings on their first transthoracic CT-guided core-needle biopsy (TTNB) were included in the study. Initial biopsy results were compared to definitive diagnoses established later. The negative predictive value (NPV) of non-malignant diseases upon initial TTNB was 83.6%. When the biopsy results indicated specific infection or benign tumour (n=225, 26.1%), they all were confirmed true negative for malignancy later. Only one inconclusive "granuloma" diagnosis was false negative. All 141 patients (141/861, 16.4%) who were false negative for malignancy were from the "infection not otherwise specified (NOS)", "inflammatory diseases", or "inconclusive" groups. Age (p=0.002), cancer history (p<0.001), target size (p=0.003), and pneumothorax during lung biopsy (p=0.003) were found to be significant predictors of false-negative results; 47.6% (410/861) of patients underwent additional invasive examinations to reach a final diagnosis. Ultimately, 52.7% (216/410) were successfully diagnosed. Specific infection, benign tumour, and granulomatous inflammation of first TTNBs were mostly true negative. Older age, history of cancer, larger target size, and pneumothorax were highly predictive of false-negative results for malignancies. In such cases, additional invasive examinations were frequently necessary to obtain final diagnoses. Copyright © 2018 The Royal College of Radiologists. Published by Elsevier Ltd. All rights reserved.

  4. Ultrastructural examination of skin biopsies may assist in diagnosing mitochondrial cytopathy when muscle biopsies yield negative results.

    PubMed

    McAfee, John L; Warren, Christine B; Prayson, Richard A

    2017-08-01

    Ultrastructural evaluation of skin biopsies has been utilized for diagnosis of mitochondrial disease. This study investigates how frequently skin biopsies reveal mitochondrial abnormalities, correlates skin and muscle biopsy findings, and describes clinical diagnoses rendered following the evaluation. A retrospective review of surgical pathology reports from 1990 to 2015 identified skin biopsies examined by electron microscopy for suspected metabolic disease. A total of 630 biopsies were included from 615 patients. Of these patients, 178 also underwent a muscle biopsy. Of the 630 skin biopsies, 75 (12%) showed ultrastructural abnormalities and 34 (5%) specifically showed mitochondrial abnormalities including increased size (n=27), reduced or abnormal cristae (n=23), dense matrices (n=20), and increased number (n=8). Additional findings included lysosomal abnormalities (n=13), lipid accumulation (n=2) or glycogen accumulation (n=1). Of the 34 patients with mitochondrial abnormalities on skin biopsy, 20 also had muscle biopsies performed and nine showed abnormalities suggestive of a mitochondrial disorder including absent cytochrome oxidase staining (n=2), increased subsarcolemmal NADH, SDH, or cytochrome oxidase staining (n=1), or ultrastructural findings including large mitochondrial size (n=5), abnormal mitochondrial structure (n=5), and increased mitochondrial number (n=4). The most common presenting symptoms were intellectual disability (n=13), seizures (n=12), encephalopathy (n=9), and gastrointestinal disturbances (n=9). At last known follow-up, 12 patients had a definitive diagnosis of a mitochondrial disorder. One patient each had Complex I deficiency, Complex III deficiency, Charcot-Marie-Tooth disease, pyruvate dehydrogenase deficiency, and Phelan-McDermid syndrome. Our results suggest that skin biopsy sometimes yields diagnostic clues suggestive of a mitochondrial cytopathy in cases with a negative muscle biopsy. Copyright © 2017 Elsevier Inc. All rights

  5. Heterogeneity of PTEN and ERG expression in prostate cancer on core needle biopsies: implications for cancer risk stratification and biomarker sampling.

    PubMed

    Shah, Rajal B; Bentley, James; Jeffery, Zach; DeMarzo, Angelo M

    2015-05-01

    ERG and PTEN biomarkers are increasingly being analyzed on prostate core biopsies (NBXs); ERG as a marker of clonality and number of separately arising tumor foci and PTEN for prognostic information. Yet, in patients with multiple biopsy cores positive for cancer (PCa), there is no standardized approach for interrogation of these biomarkers in terms of the number of positive cores to evaluate. A total of 194 NBX cases containing more than one positive core with cancer were evaluated for ERG overexpression and PTEN loss by immunostaining (immunohistochemistry) of all positive cores. ERG overexpression or PTEN loss in at least one cancer core was present in 111 (57%) and 69 (36%) cases respectively. ERG overexpression was significantly associated with PTEN loss (P < .0001), and PTEN loss was associated with a high Gleason score (P < .0001). Inter- and intra-tumor core staining heterogeneity for ERG overexpression occurred in 42% and 5% cases and for PTEN loss both intra- and inter-tumor core heterogeneity was 68%. PTEN staining was highly discordant between PCa sites regardless of laterality. When the Gleason score was non-uniform across PCa sites, the combination of cores showing the highest Gleason score and largest tumor volume provided the best representation of ERG overexpression (92%) and PTEN loss (98%). When grades were uniform across cancer sites, the highest tumor volume core was generally representative of ERG overexpression (90%) but was less representative for PTEN loss (76%). Our results suggest that knowledge of this heterogeneity is critical for developing optimal yet cost-effective strategies to identify these underlying molecular abnormalities. Copyright © 2015 Elsevier Inc. All rights reserved.

  6. Total cost comparison of 2 biopsy methods for nonpalpable breast lesions.

    PubMed

    Bodai, B I; Boyd, B; Brown, L; Wadley, H; Zannis, V J; Holzman, M

    2001-05-01

    To identify, quantify, and compare total facility costs for 2 breast biopsy methods: vacuum-assisted biopsy (VAB) and needle-wire-localized open surgical biopsy (OSB). A time-and-motion study was done to identify unit resources used in both procedures. Costs were imputed from published literature to value resources. A comparison of the total (fixed and variable) costs of the 2 procedures was done. A convenience sample of 2 high-volume breast biopsy (both VAB and OSB) facilities was identified. A third facility (OSB only) and 8 other sites (VAB only) were used to capture variation. Staff interviews, patient medical records, and billing data were used to check observed data. One hundred and sixty-seven uncomplicated procedures (71 OSBs, 96 VABs) were observed. Available demographic and clinical data were analyzed to assess selection bias, and sensitivity analyses were done on the main assumptions. The total facility costs of the VAB procedure were lower than the costs of the OSB procedure. The overall cost advantage for using VAB ranges from $314 to $843 per procedure depending on the facility type. Variable cost comparison indicated little difference between the 2 procedures. The largest fixed cost difference was $763. Facilities must consider the cost of new technology, especially when the new technology is as effective as the present technology. The seemingly high cost of equipment might negatively influence a decision to adopt VAB, but when total facility costs were analyzed, the new technology was less costly.

  7. Microincision, aspiration cutter-assisted multifocal iris biopsy for melanoma.

    PubMed

    Finger, Paul T; Milman, Tatyana

    2017-01-19

    To describe a minimally invasive method to create multifocal full-thickness surgical iridectomy biopsies. Seven patients suspected to have diffuse iris melanoma underwent multifocal surgical iridectomy biopsy through a single 1.0-mm clear corneal incision. A 25-G inked trocar was used to create one visible corneal portal, through which the anterior chamber was filled with sodium hyaluronate 1%. Then, a 25-G aspiration cutter probe was introduced through the corneal incision such that the aspiration portal was occluded by the iris biopsy sites. Then aspiration (600 mm Hg) cutting (300 cuts per minute) was used to create full- and partial-thickness surgical iridectomy biopsies at multiple locations. After each biopsy the probe was removed, and its contents aspirated into a separate 3-mL syringe (marked by clock hour location). The sodium hyaluronate 1% was removed and wound checked for leakage. Diagnostic specimens were obtained in all cases. Five were found to be diffuse iris melanomas and 2 were indeterminate iris melanocytic proliferations. No patients developed a secondary increase in intraocular pressure, hyphema, infection, cataract, or vision loss. No cases of intraocular tumor dissemination were observed. No patient complained of glare or monocular diplopia. Three of 7 corneal wounds were self-sealing. Multifocal surgical iridectomy biopsy can be minimally invasive and effective allowing for partial- and full-thickness iris biopsy. Use of a 25-G aspiration cutting probe allowed for small incision surgery, rapid rehabilitation, and no significant complications.

  8. CT fluoroscopy-guided core needle biopsy of anterior mediastinal masses.

    PubMed

    Iguchi, T; Hiraki, T; Matsui, Y; Fujiwara, H; Sakurai, J; Masaoka, Y; Uka, M; Tanaka, T; Gobara, H; Kanazawa, S

    2018-02-01

    To retrospectively evaluate the safety, diagnostic yield, and risk factors of diagnostic failure of computed tomography (CT) fluoroscopy-guided biopsies of anterior mediastinal masses. Biopsy procedures and results of anterior mediastinal masses in 71 patients (32 women/39 men; mean [±standard deviation] age, 53.8±20.0years; range, 14-88years) were analyzed. Final diagnoses were based on surgical outcomes, imaging findings, or clinical follow-up findings. The biopsy results were compared with the final diagnosis, and the biopsy procedures grouped by pathologic findings into diagnostic success and failure groups. Multiple putative risk factors for diagnostic failure were then assessed. Seventy-one biopsies (71 masses; mean size, 67.5±27.3mm; range 8.6-128.2mm) were analyzed. We identified 17 grade 1 and one grade 2 adverse events (25.4% overall) according to the National Cancer Institute Common Terminology Criteria for Adverse Events version 4.0. Sixty-nine biopsies (97.2%) provided samples fit for pathologic analysis. Diagnostic failure was found for eight (11.3%) masses; the 63 masses diagnosed successfully included thymic carcinoma (n=17), lung cancer (n=14), thymoma (n=12), malignant lymphoma (n=11), germ cell tumor (n=3), and others (n=6). Using a thinner needle (i.e., a 20-gauge needle) was the sole significant risk factor for diagnostic failure (P=0.039). CT fluoroscopy-guided biopsy of anterior mediastinal masses was safe and had a high diagnostic yield; however, using a thinner biopsy needle significantly increased the risk of a failed diagnosis. Copyright © 2017 Éditions françaises de radiologie. Published by Elsevier Masson SAS. All rights reserved.

  9. Prognostic importance of Gleason 7 disease among patients treated with external beam radiation therapy for prostate cancer: results of a detailed biopsy core analysis.

    PubMed

    Spratt, Daniel E; Zumsteg, Zach; Ghadjar, Pirus; Pangasa, Misha; Pei, Xin; Fine, Samson W; Yamada, Yoshiya; Kollmeier, Marisa; Zelefsky, Michael J

    2013-04-01

    To analyze the effect of primary Gleason (pG) grade among a large cohort of Gleason 7 prostate cancer patients treated with external beam radiation therapy (EBRT). From May 1989 to January 2011, 1190 Gleason 7 patients with localized prostate cancer were treated with EBRT at a single institution. Of these patients, 613 had a Gleason 7 with a minimum of a sextant biopsy with nonfragmented cores and full biopsy core details available, including number of cores of cancer involved, percentage individual core involvement, location of disease, bilaterality, and presence of perineural invasion. Median follow-up was 6 years (range, 1-16 years). The prognostic implication for the following outcomes was analyzed: biochemical recurrence-free survival (bRFS), distant metastasis-free survival (DMFS), and prostate cancer-specific mortality (PCSM). The 8-year bRFS rate for pG3 versus pG4 was 77.6% versus 61.3% (P<.0001), DMFS was 96.8% versus 84.3% (P<.0001), and PCSM was 3.7% versus 8.1% (P=.002). On multivariate analysis, pG4 predicted for significantly worse outcome in all parameters. Location of disease (apex, base, mid-gland), perineural involvement, maximum individual core involvement, and the number of Gleason 3+3, 3+4, or 4+3 cores did not predict for distant metastases. Primary Gleason grade 4 independently predicts for worse bRFS, DMFS, and PCSM among Gleason 7 patients. Using complete core information can allow clinicians to utilize pG grade as a prognostic factor, despite not having the full pathologic details from a prostatectomy specimen. Future staging and risk grouping should investigate the incorporation of primary Gleason grade when complete biopsy core information is used. Copyright © 2013 Elsevier Inc. All rights reserved.

  10. Prognostic Importance of Gleason 7 Disease Among Patients Treated With External Beam Radiation Therapy for Prostate Cancer: Results of a Detailed Biopsy Core Analysis

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Spratt, Daniel E.; Zumsteg, Zach; Ghadjar, Pirus

    2013-04-01

    Purpose: To analyze the effect of primary Gleason (pG) grade among a large cohort of Gleason 7 prostate cancer patients treated with external beam radiation therapy (EBRT). Methods and Materials: From May 1989 to January 2011, 1190 Gleason 7 patients with localized prostate cancer were treated with EBRT at a single institution. Of these patients, 613 had a Gleason 7 with a minimum of a sextant biopsy with nonfragmented cores and full biopsy core details available, including number of cores of cancer involved, percentage individual core involvement, location of disease, bilaterality, and presence of perineural invasion. Median follow-up was 6more » years (range, 1-16 years). The prognostic implication for the following outcomes was analyzed: biochemical recurrence-free survival (bRFS), distant metastasis-free survival (DMFS), and prostate cancer-specific mortality (PCSM). Results: The 8-year bRFS rate for pG3 versus pG4 was 77.6% versus 61.3% (P<.0001), DMFS was 96.8% versus 84.3% (P<.0001), and PCSM was 3.7% versus 8.1% (P=.002). On multivariate analysis, pG4 predicted for significantly worse outcome in all parameters. Location of disease (apex, base, mid-gland), perineural involvement, maximum individual core involvement, and the number of Gleason 3+3, 3+4, or 4+3 cores did not predict for distant metastases. Conclusions: Primary Gleason grade 4 independently predicts for worse bRFS, DMFS, and PCSM among Gleason 7 patients. Using complete core information can allow clinicians to utilize pG grade as a prognostic factor, despite not having the full pathologic details from a prostatectomy specimen. Future staging and risk grouping should investigate the incorporation of primary Gleason grade when complete biopsy core information is used.« less

  11. Predictors of invasive breast cancer in mammographically detected microcalcification in patients with a core biopsy diagnosis of flat epithelial atypia, atypical ductal hyperplasia or ductal carcinoma in situ and recommendations for a selective approach to sentinel lymph node biopsy.

    PubMed

    Catteau, Xavier; Simon, Philippe; Noël, Jean-Christophe

    2012-04-15

    15±30% of malignancies detected through screening programs are ductal carcinoma in situ (DCIS), and the majority of DCIS cases present in the form of mammographic microcalcification. This study was performed in order to determine the value of features in predicting invasive disease in patients with mammographic calcification and to help determine which patients (with, Core Needle Biopsy-diagnosed DCIS) are the most appropriate candidates for Sentinel Lymph Node (SLN) biopsy. The original aspect of this study was to select patients with mammographic microcalcification but without an associated mass. The factor that we identified to be associated with invasive disease at final surgical excision was the presence of necrosis at core histology. SLN biopsy or complete axillary lymph node dissection was performed in 22 (40%) patients of whom only one (4.5%) had a micrometastasis. Further larger studies are needed to see if it would be interesting to propose a SLN biopsy in case of necrosis on CNB-diagnosed DCIS with microcalcifications but not associated with a mass. Copyright © 2012 Elsevier GmbH. All rights reserved.

  12. Feasibility of Image-Guided Transthoracic Core Needle Biopsy in the BATTLE Lung Trial

    PubMed Central

    Tam, Alda L.; Kim, Edward S.; Lee, J. Jack; Ensor, Joe E.; Hicks, Marshall E.; Tang, Ximing; Blumenschein, George R.; Alden, Christine M.; Erasmus, Jeremy J.; Tsao, Anne; Lippman, Scott M.; Hong, Waun K.; Wistuba, Ignacio I.; Gupta, Sanjay

    2013-01-01

    Purpose As therapy for non-small cell lung cancer (NSCLC) patients becomes more personalized, additional tissue in the form of core needle biopsies (CNBs) for biomarker analysis is increasingly required for determining appropriate treatment and for enrollment into clinical trials. We report our experience with small-caliber percutaneous transthoracic (PT) CNBs for the evaluation of multiple molecular biomarkers in BATTLE (Biomarker-integrated Approaches of Targeted Therapy for Lung Cancer Elimination), a personalized, targeted therapy NSCLC clinical trial. Methods The medical records of patients who underwent PTCNB for consideration of enrollment in BATTLE, were reviewed for diagnostic yield of 11 predetermined molecular markers, and procedural complications. Univariate and multivariate analyses of factors related to patient and lesion characteristics were performed to determine possible influences on diagnostic yield. Results One hundred and seventy PTCNBs were performed using 20-gauge biopsy needles in 151 NSCLC patients screened for the trial. 82.9% of the biopsy specimens were found to have adequate tumor tissue for analysis of the required biomarkers. On multivariate analysis, metastatic lesions were 5.4 times more likely to yield diagnostic tissue as compared to primary tumors (p = 0.0079). Pneumothorax and chest tube insertion rates were 15.3% and 9.4%, respectively. Conclusions Image-guided 20-gauge PTCNB is safe and provides adequate tissue for analysis of multiple biomarkers in the majority of patients being considered for enrollment into a personalized, targeted therapy NSCLC clinical trial. Metastatic lesions are more likely to yield diagnostic tissue as compared to primary tumors. PMID:23442309

  13. Matrix Characterization and Development for the Vacuum Assisted Resin Transfer Molding Process

    NASA Technical Reports Server (NTRS)

    Grimsley, B. W.; Hubert, P.; Hou, T. H.; Cano, R. J.; Loos, A. C.; Pipes, R. B.

    2001-01-01

    The curing kinetics and viscosity of an epoxy resin system, SI-ZG-5A, have been characterized for application in the vacuum assisted resin transfer molding (VARTM) process. Impregnation of a typical carbon fiber perform provided the test bed for the characterization. Process simulations were carried out using the process model, COMPRO, to examine heat transfer and curing kinetics for a fully impregnated panel, neglecting resin flow. The predicted viscosity profile and final degree of cure were found to be in good agreement with experimental observations.

  14. Diagnostic performance of power doppler and ultrasound contrast agents in early imaging-based diagnosis of organ-confined prostate cancer: Is it possible to spare cores with contrast-guided biopsy?

    PubMed

    Delgado Oliva, F; Arlandis Guzman, S; Bonillo García, M; Broseta Rico, E; Boronat Tormo, F

    2016-10-01

    To evaluate the diagnostic performance of gray scale transrectal ultrasound-B-mode US (BMUS), power Doppler (PDUS), and sonographic contrast (CEUS) in early imaging-based diagnosis of localized prostate cancer (PCa) and to compare the diagnostic profitability of randomized biopsy (RB), US-targeted prostate biopsy by means of PDUS and CEUS. A single-center, prospective, transversal, epidemiological study was conducted from January 2010 to January 2014. We consecutively included patients who an imaging study of the prostate with BMUS, PDUS, and CEUS was performed, followed by prostate biopsy due to clinical suspicion of prostate cancer (PSA 4-20ng/mL and/or rectal exam suggestive of malignancy). The diagnostic performance of BMUS, PDUS, and CEUS was determined by calculating the Sensitivity (S), Specificity (Sp), Predictive values (PV), and diagnostic odds ratio (OR) of the diagnosis tests and, for these variables, in the population general and based on their clinical stage according to rectal exam (cT1 and cT2). PCa detection rates determined by means of a randomized 10-core biopsy scheme were compared with detection rates of CEUS-targeted (SonoVue) 2-core biopsies. Of the initial 984 patients, US contrast SonoVue was administered to 179 (18.2%). The PCa detection rate by organ of BMUS/PDUS in the global population was 38% versus 43% in the subpopulation with CEUS. The mean age of the patients was 64.3±7.01years (95% CI, 63.75-64.70); mean total PSA was 8.9±3.61ng/mL (95% CI, 8.67-9.13) and the mean prostate volume was 56.2±29cc (95% CI, 54.2-58.1). The detection rate by organ of targeted biopsy with BMUS, PDUS, and CEUS were as follows: Global population (10.6, 8.2, 24.5%), stage cT1 (5.6, 4.2, 16.4%), and stage cT2 (32.4, 22.3, 43.5%). Comparing the detection rates of the CEUS-targeted biopsy and randomized biopsy, the following results were obtained: Global population (24.5% vs. 41.8%), stage cT1 (16% vs. 35%), and stage cT2 (43.5% vs. 66.6%), with a p value<0

  15. Ultrasound-assisted extraction coupled with under vacuum distillation of flavour compounds from spearmint (carvone-rich) plants: Comparison with conventional hydrodistillation.

    PubMed

    Da Porto, Carla; Decorti, Deborha

    2009-08-01

    Ultrasonically assisted extraction of flavour compounds from different varieties of Mentha spicata, using 70% ethanol, have been carried out for 5, 10 and 15min and coupled with under vacuum distillation. The ultrasound distilled extracts have been analysed by GC-MS and compared with essential oils obtained by hydrodistillation. The results have showed that ultrasonically assisted extraction in combination with under vacuum distillation have provided extracts with higher flavouring strength due to the increased concentration of desirable oxygenated compounds (from 5 to 8 times) compared with hydrodistillation. Extraction yields of flavour volatiles have been calculated giving a range 0.04-0.13% by ultrasound and 0.01-0.02% by hydrodistillation.

  16. Feasibility of computed tomography-guided core needle biopsy in producing state-of-the-art clinical management in Chinese lung cancer

    PubMed Central

    Chen, Hua-Jun; Yang, Jin-Ji; Fang, Liang-Yi; Huang, Min-Min; Yan, Hong-Hong; Zhang, Xu-Chao; Xu, Chong-Rui; Wu, Yi-Long

    2014-01-01

    Background A satisfactory biopsy determines the state-of-the-art management of lung cancer in this era of personalized medicine. This study aimed to investigate the suitability and efficacy of computed tomography (CT)-guided core needle biopsy in clinical management. Methods A cohort of 353 patients with clinically suspected lung cancer was enrolled in the study. Patient factors and biopsy variables were recorded. Epidermal growth factor receptor (EGFR) gene mutations and echinoderm microtubule-associated protein-like 4 (EML4)-anaplastic lymphoma kinase (ALK) rearrangement were detected in tumor specimens. Adequacy of biopsic obtainment for clinical trial screening and tissue bank establishment were reviewed. Results Overall diagnostic accuracy of malignancy achieved 98.5%. The median biopsy time of the cohort was 20 minutes. In patients with non-small cell lung cancer (NSCLC), 99.3% (287/289) were diagnosed as specific histologic subtypes, and two patients (0.7%) were determined as NSCLC not otherwise specified (NOS). EGFR mutations were analyzed in 81.7% (236/289) of patients with NSCLC, and 98.7% (233/236) showed conclusive results. EML4-ALK gene fusion was tested in 43.9% (127/289) of NSCLC patients, and 98.4% (125/127) showed conclusive results: 6.4% (8/125) of those had gene fusion. Ninety-six NSCLC patients participated in clinical trial screening and provided mandatory tumor slides for molecular profiling. Pathological evaluation was fulfilled in 90 patients (93.8%); 99.4% (320/322) of patients with malignancy provided extra tissue for the establishment of a tumor bank. Conclusions CT-guided core needle biopsy provided optimal clinical management in this era of translational medicine. The biopsic modality should be prioritized in selected lung cancer patients. PMID:26766993

  17. Infrared needle mapping to assist biopsy procedures and training.

    PubMed

    Shar, Bruce; Leis, John; Coucher, John

    2018-04-01

    A computed tomography (CT) biopsy is a radiological procedure which involves using a needle to withdraw tissue or a fluid specimen from a lesion of interest inside a patient's body. The needle is progressively advanced into the patient's body, guided by the most recent CT scan. CT guided biopsies invariably expose patients to high dosages of radiation, due to the number of scans required whilst the needle is advanced. This study details the design of a novel method to aid biopsy procedures using infrared cameras. Two cameras are used to image the biopsy needle area, from which the proposed algorithm computes an estimate of the needle endpoint, which is projected onto the CT image space. This estimated position may be used to guide the needle between scans, and results in a reduction in the number of CT scans that need to be performed during the biopsy procedure. The authors formulate a 2D augmentation system which compensates for camera pose, and show that multiple low-cost infrared imaging devices provide a promising approach.

  18. Core-needle biopsy of breast cancer is associated with a higher rate of distant metastases 5 to 15 years after diagnosis than FNA biopsy.

    PubMed

    Sennerstam, Roland B; Franzén, Bo S H; Wiksell, Hans O T; Auer, Gert U

    2017-10-01

    The literature offers discordant results regarding whether diagnostic biopsy is associated with the dissemination of cancer cells, resulting in local and/or distant metastasis. The long-term outcomes of patients with breast cancer were compared between those who were diagnosed using either fine-needle aspiration biopsy (FNAB) or core-needle biopsy (CNB) during 2 decades: the 1970s and 1990s. In the 1970s, the only diagnostic needle biopsy method used for breast cancer in Sweden was FNAB. CNB was introduced 1989 and became established in Stockholm Gotland County in the early 1990s. The authors compared the clinical outcomes of patients diagnosed using FNAB from 1971 to 1976 (n = 354) versus those of patients diagnosed using CNB from 1991 to 1995 (n = 1729). Adjusting for differences in various treatment modalities, mammography screening, tumor size, DNA ploidy, and patient age between the 2 decades, 2 strictly matched samples representing FNAB (n = 181) and CNB (n = 203) were selected for a 15-year follow-up study. In a comparison of the rates of distant metastasis in the strictly matched patient groups from the FNAB and CNB cohorts, significantly higher rates of late-appearing (5-15 years after diagnosis) distant metastasis were observed among the patients who were diagnosed on CNB compared with those who were diagnosed on FNAB. No significant difference in local metastasis was observed between the 2 groups. At 5 to 15 years after diagnosis of the primary tumor, CNB-diagnosed patients had significantly higher rates of distant metastases than FNAB-diagnosed patients. Cancer Cytopathol 2017;125:748-56. © 2017 American Cancer Society. © 2017 American Cancer Society.

  19. Bone marrow solid core biopsy needle: a critical assessment of the utility, benefits and limitations of the instruments employed in current day haematology and oncology.

    PubMed

    Islam, Anwarul

    2018-06-01

    The optimal clinical evaluation of the bone marrow requires an examination of air-dried and well-stained films of the aspirated tissue along with a histopathological evaluation of adequately processed and properly stained core biopsy specimens. A bone marrow evaluation can be essential in establishing a diagnosis, determining the efficacy of treatment in haematological disorders and to monitor haematological status of patients following bone marrow/stem cell transplantation. It is also an essential component of the staging process for newly diagnosed malignancies. Currently available bone marrow aspiration needles are quite satisfactory and if properly used provide good-quality specimens for morphological evaluation. However, if a bone marrow core biopsy is concerned, several needles are currently in use but not all of them provide good-quality biopsy specimens for histological evaluation or are user friendly. We have compared the recently introduced Moeller Medical single use bone marrow core biopsy needle with the Jamshidi needle with marrow acquisition cradle (CareFusion), J-needle (Cardinal Health) and OnControl device (Vidacare). It is concluded that the Moeller Medical needle system has definite advantages over others and is recommended for routine use. © Article author(s) (or their employer(s) unless otherwise stated in the text of the article) 2018. All rights reserved. No commercial use is permitted unless otherwise expressly granted.

  20. The effectiveness of inking needle core prostate biopsies for preventing patient specimen identification errors: a technique to address Joint Commission patient safety goals in specialty laboratories.

    PubMed

    Raff, Lester J; Engel, George; Beck, Kenneth R; O'Brien, Andrea S; Bauer, Meagan E

    2009-02-01

    The elimination or reduction of medical errors has been a main focus of health care enterprises in the United States since the year 2000. Elimination of errors in patient and specimen identification is a key component of this focus and is the number one goal in the Joint Commission's 2008 National Patient Safety Goals Laboratory Services Program. To evaluate the effectiveness of using permanent inks to maintain specimen identity in sequentially submitted prostate needle biopsies. For a 12-month period, a grossing technician stained each prostate core with permanent ink developed for inking of pathology specimens. A different color was used for each patient, with all the prostate cores from all vials for a particular patient inked with the same color. Five colors were used sequentially: green, blue, yellow, orange, and black. The ink was diluted with distilled water to a consistency that allowed application of a thin, uniform coating of ink along the edges of the prostate core. The time required to ink patient specimens comprising different numbers of vials and prostate biopsies was timed. The number and type of inked specimen discrepancies were evaluated. The identified discrepancy rate for prostate biopsy patients was 0.13%. The discrepancy rate in terms of total number of prostate blocks was 0.014%. Diluted inks adhered to biopsy contours throughout tissue processing. The tissue showed no untoward reactions to the inks. Inking did not affect staining (histochemical or immunohistochemical) or pathologic evaluation. On average, inking prostate needle biopsies increases grossing time by 20%. Inking of all prostate core biopsies with colored inks, in sequential order, is an aid in maintaining specimen identity. It is a simple and effective method of addressing Joint Commission patient safety goals by maintaining specimen identity during processing of similar types of gross specimens. This technique may be applicable in other specialty laboratories and high

  1. Sonographically guided percutaneous muscle biopsy in diagnosis of neuromuscular disease: a useful alternative to open surgical biopsy.

    PubMed

    O'Sullivan, Paul J; Gorman, Grainne M; Hardiman, Orla M; Farrell, Michael J; Logan, P Mark

    2006-01-01

    The purpose of this study was to evaluate the feasibility of sonographically guided percutaneous muscle biopsy in the investigation of neuromuscular disorders. Sonographically guided percutaneous needle biopsy of skeletal muscle was performed with a 14-gauge core biopsy system in 40 patients over a 24-month period. Patients were referred from the Department of Neurology under investigation for neuromuscular disorders. Sonography was used to find suitable tissue and to avoid major vascular structures. A local anesthetic was applied below skin only. A 3- to 4-mm incision was made. Three 14-gauge samples were obtained from each patient. All samples were placed on saline-dampened gauze and sent for neuropathologic analysis. As a control, we retrospectively assessed results of the 40 most recent muscle samples acquired via open surgical biopsy. With the use of sonography, 32 (80%) of 40 patients had a histologic diagnosis made via percutaneous needle biopsy. This included 26 (93%) of 28 patients with acute muscular disease and 6 (50%) of 12 patients with chronic disease. In the surgical group (all acute disease), 38 (95%) of 40 patients had diagnostic tissue attained. Sonographically guided percutaneous 14-gauge core skeletal muscle biopsy is a useful procedure, facilitating diagnosis in acute muscular disease. It provides results comparable with those of open surgical biopsy in acute muscular disease. It may also be used in chronic muscular disease but repeated or open biopsy may be needed.

  2. Feasibility and Diagnostic Yield of Endoscopic Ultrasonography-Guided Fine Needle Biopsy With a New Core Biopsy Needle Device in Patients With Gastric Subepithelial Tumors

    PubMed Central

    Lee, Minju; Min, Byung-Hoon; Lee, Hyuk; Ahn, Sangjeong; Lee, Jun Haeng; Rhee, Poong-Lyul; Kim, Jae J.; Sohn, Tae Sung; Kim, Sung; Kim, Kyoung-Mee

    2015-01-01

    Abstract As treatment decisions for patients with gastric subepithelial tumors (SETs) largely depend on the histopathologic diagnosis, noninvasive and effective tissue acquisition methods are definitely required for proper management of gastric SETs. Recently, a new endoscopic ultrasonography-guided fine needle biopsy (EUS-FNB) device with ProCore reverse bevel technology was developed. We aimed to elucidate the feasibility and diagnostic yield of EUS-FNB with this new core biopsy needle device in patients with gastric SETs. A prospectively maintained database was retrospectively reviewed to identify consecutive patients who underwent EUS-FNB with a 22-gauge ProCore needle for gastric SETs 2 cm or larger. The main outcome measurement was the diagnostic yield of EUS-FNB. Procedure results were categorized into diagnostic, suggestive, or nondiagnostic. Of the 43 patients, needle punctures were successful in all cases irrespective of tumor location. EUS-FNB procedure results were diagnostic in 86.0%, suggestive in 4.7%, and nondiagnostic in 9.3% of cases, respectively. The diagnostic yield was the highest in fundus (100.0%), followed by body (89.5%), cardia (83.3%), and antrum (50.0%). All 18 patients with cardiac SET were finally diagnosed to have leiomyoma, and 16 patients with diagnostic or suggestive results avoided surgery. A heterogeneous echo pattern on EUS was found in 33.3% of cases with nondiagnostic or suggestive results and in 5.4% with diagnostic results. In multivariate analysis, no independent predictor of unsuccessful EUS-FNB with nondiagnostic or suggestive results was identified. Agreement between EUS-FNB and surgical pathology was 100% with respect to the diagnosis of gastrointestinal stromal tumor. However, there was a significant discrepancy in mitotic counts observed between the EUS-FNB and surgical specimens in patients with gastrointestinal stromal tumor. There were no significant procedure-related adverse events during and after the

  3. Comparison of Histologic Core Portions Acquired from a Core Biopsy Needle and a Conventional Needle in Solid Mass Lesions: A Prospective Randomized Trial.

    PubMed

    Lee, Ban Seok; Cho, Chang-Min; Jung, Min Kyu; Jang, Jung Sik; Bae, Han Ik

    2017-07-15

    The superiority of endoscopic ultrasound-guided fine needle biopsy (EUS-FNB) over EUS-guided fine needle aspiration (EUS-FNA) remains controversial. Given the lack of studies analyzing histologic specimens acquired from EUS-FNB or EUS-FNA, we compared the proportion of the histologic core obtained from both techniques. A total of 58 consecutive patients with solid mass lesions were enrolled and randomly assigned to the EUS-FNA or EUS-FNB groups. The opposite needle was used after the failure of core tissue acquisition using the initial needle with up to three passes. Using computerized analyses of the scanned histologic slide, the overall area and the area of the histologic core portion in specimens obtained by the two techniques were compared. No significant differences were identified between the two groups with respect to demographic and clinical characteristics. Fewer needle passes were required to obtain core specimens in the FNB group (p<0.001). There were no differences in the proportion of histologic core (11.8%±19.5% vs 8.0%±11.1%, p=0.376) or in the diagnostic accuracy (80.6% vs 81.5%, p=0.935) between two groups. The proportion of histologic core and the diagnostic accuracy were comparable between the FNB and FNA groups. However, fewer needle passes were required to establish an accurate diagnosis in EUS-FNB.

  4. External validation of urinary PCA3-based nomograms to individually predict prostate biopsy outcome.

    PubMed

    Auprich, Marco; Haese, Alexander; Walz, Jochen; Pummer, Karl; de la Taille, Alexandre; Graefen, Markus; de Reijke, Theo; Fisch, Margit; Kil, Paul; Gontero, Paolo; Irani, Jacques; Chun, Felix K-H

    2010-11-01

    Prior to safely adopting risk stratification tools, their performance must be tested in an external patient cohort. To assess accuracy and generalizability of previously reported, internally validated, prebiopsy prostate cancer antigen 3 (PCA3) gene-based nomograms when applied to a large, external, European cohort of men at risk of prostate cancer (PCa). Biopsy data, including urinary PCA3 score, were available for 621 men at risk of PCa who were participating in a European multi-institutional study. All patients underwent a ≥10-core prostate biopsy. Biopsy indication was based on suspicious digital rectal examination, persistently elevated prostate-specific antigen level (2.5-10 ng/ml) and/or suspicious histology (atypical small acinar proliferation of the prostate, >/= two cores affected by high-grade prostatic intraepithelial neoplasia in first set of biopsies). PCA3 scores were assessed using the Progensa assay (Gen-Probe Inc, San Diego, CA, USA). According to the previously reported nomograms, different PCA3 score codings were used. The probability of a positive biopsy was calculated using previously published logistic regression coefficients. Predicted outcomes were compared to the actual biopsy results. Accuracy was calculated using the area under the curve as a measure of discrimination; calibration was explored graphically. Biopsy-confirmed PCa was detected in 255 (41.1%) men. Median PCA3 score of biopsy-negative versus biopsy-positive men was 20 versus 48 in the total cohort, 17 versus 47 at initial biopsy, and 37 versus 53 at repeat biopsy (all p≤0.002). External validation of all four previously reported PCA3-based nomograms demonstrated equally high accuracy (0.73-0.75) and excellent calibration. The main limitations of the study reside in its early detection setting, referral scenario, and participation of only tertiary-care centers. In accordance with the original publication, previously developed PCA3-based nomograms achieved high accuracy and

  5. Drying based on temperature-detection-assisted control in microwave-assisted pulse-spouted vacuum drying.

    PubMed

    Cao, Xiaohuang; Zhang, Min; Qian, He; Mujumdar, Arun S

    2017-06-01

    An online temperature-detection-assisted control system of microwave-assisted pulse-spouted vacuum drying was newly developed. By using this system, temperature control can be automatically and continuously adjusted based on the detection of drying temperature and preset temperature. Various strategies for constant temperature control, linear temperature control and three-step temperature control were applied to drying carrot cubes. Drying kinetics and the quality of various temperature-controlled strategies online are evaluated for the new drying technology as well as its suitability as an alternative drying method. Drying time in 70 °C mode 1 had the shortest drying time and lowest energy consumption in all modes. A suitable colour, highest re-hydration ratio and fracture-hardness, and longest drying time occurred in 30-40-50 °C mode 3. The number of hot spots was reduced in 40-50-60 °C mode 3. Acceptable carrot snacks were obtained in 50-60-70 °C mode 3 and 70 °C mode 2. All temperature curves showed that the actual temperatures followed the preset temperatures appropriately. With this system, a linear temperature-controlled strategy and a three-step temperature-controlled strategy can improve product quality and heating non-uniformity compared to constant temperature control, but need greater energy consumption and longer drying time. A temperature-detection-assisted control system was developed for providing various drying strategies as a suitable alternative in making a snack product. © 2016 Society of Chemical Industry. © 2016 Society of Chemical Industry.

  6. Execution of robot-assisted biopsies within the clinical context.

    PubMed

    Rovetta, A; Sala, R

    1995-01-01

    This paper describes the first prostatic biopsy on a human patient using a robotic and telerobotic system. This system was designed at the Politecnico di Milano, and the biopsy was performed on April 7, 1995, in the Hospital Policlinico in Milan, Italy.

  7. Polyimide Composites Properties of RTM370 Fabricated by Vacuum Assisted Resins Transfer Molding (VARTM)

    NASA Technical Reports Server (NTRS)

    Chuang, Kathy C.; Criss, Jim M.; Mintz, Eric A.

    2011-01-01

    RTM370 imide resin based on 2,3,3 ,4 -biphenyl dianhydride ( a-BPDA), 3,4 -oxydianinline (3,4 -ODA) with 4-phenylethynylphthalic (PEPA) endcap has shown to exhibit high Tg (370 C) and low melt viscosity (10-30 poise) at 280 C with a pot-life of 1-2 h. Previously, RTM370 resin has been fabricated into composites with T650-35 carbon fabrics by resin transfer molding (RTM) successfully. RTM370 composites exhibit excellent mechanical properties up to 327 C (620 F), and outstanding property retention after aging at 288 C (550 F) for 1000 hrs. In this presentation, RTM 370 composites will be fabricated by vacuum assisted resins transfer molding (VARTM), using vacuum bags without mold. The mechanical properties of RTM370 composites fabricated by VARTM will be compared to those of RTM370 made by RTM.

  8. Magnetic Resonance Imaging Targeted Biopsy Improves Selection of Patients Considered for Active Surveillance for Clinically Low Risk Prostate Cancer Based on Systematic Biopsies.

    PubMed

    Ouzzane, Adil; Renard-Penna, Raphaele; Marliere, François; Mozer, Pierre; Olivier, Jonathan; Barkatz, Johann; Puech, Philippe; Villers, Arnauld

    2015-08-01

    Current selection criteria for active surveillance based on systematic biopsy underestimate prostate cancer volume and grade. We investigated the role of additional magnetic resonance imaging targeted biopsy in reclassifying patients eligible for active surveillance based on systematic biopsy. We performed a study at 2 institutions in a total of 281 men with increased prostate specific antigen. All men met certain criteria, including 1) prebiopsy magnetic resonance imaging, 12-core transrectal systematic biopsy and 2 additional magnetic resonance imaging targeted biopsies of lesions suspicious for cancer during the same sequence as systematic biopsy, and 2) eligibility for active surveillance based on systematic biopsy results. Criteria for active surveillance were prostate specific antigen less than 10 ng/ml, no Gleason grade 4/5, 5 mm or less involvement of any biopsy core and 2 or fewer positive systematic biopsy cores. Patient characteristics were compared between reclassified and nonreclassified groups based on magnetic resonance imaging targeted biopsy results. On magnetic resonance imaging 58% of the 281 patients had suspicious lesions. Magnetic resonance imaging targeted biopsy was positive for cancer in 81 of 163 patients (50%). Of 281 patients 28 (10%) were reclassified by magnetic resonance imaging targeted biopsy as ineligible for active surveillance based on Gleason score in 8, cancer length in 20 and Gleason score plus cancer length in 9. Suspicious areas on magnetic resonance imaging were in the anterior part of the prostate in 15 of the 28 men (54%). Reclassified patients had a smaller prostate volume (37 vs 52 cc) and were older (66.5 vs 63 years) than those who were not reclassified (p < 0.05). Magnetic resonance imaging targeted biopsy reclassified 10% of patients who were eligible for active surveillance based on systematic biopsy. Its incorporation into the active surveillance eligibility criteria may decrease the risk of reclassification to

  9. Pathology in patients with ventricular assist devices: a study of 21 autopsies, 24 ventricular apical core biopsies and 24 explanted hearts.

    PubMed

    Rose, Alan G; Park, Soon J

    2005-01-01

    Ventricular assist devices (VADs) are used as a bridge to cardiac transplantation or as a permanent or sometimes temporary treatment for end stage heart failure. Our autopsy and surgical pathology experience with VADs prior to August 2002 was reviewed. Noted were patient's age, sex, underlying (UCOD) and proximate causes of death (PCOD), duration of VAD implantation, presence of native or prosthetic valvar disease and organ complications. Myocardium from biopsies and explanted hearts were blindly assessed for coagulative necrosis (CN), contraction bands (CB), myocytolysis (MC), increased eosinophilia (IE), myocyte waviness (MW) and fibrosis (F). Each was graded as either mild (score 1), moderate (score 2) or severe (score 3). Autopsy patients: Twenty-one patients, with mean age 55 years (range 10-73), comprised 10 women and 11 men. UCOD was ischemic disease in 16 patients, dilated cardiomyopathy in 4 and aortic valve disease in 1. The mean duration of VAD implantation was 125.7 days (range 1-1095 days, S.D.=253.6). Five patients had biventricular VADs, and 16 had LVAD only. Acquired aortic valve fusion was noted in three patients. PCOD was VAD related in six, donor heart problem in four, cerebrovascular accident in four, miscellaneous in three, pulmonary hypertension in two and aortic disease in two patients. Morbidity: local liver necrosis in seven, acquired aortic valve disease in four, gut infarction in three, abdominal aortic aneurysm in two and host cell assault against VAD porcine aortic valves in one case. Biopsies and explanted hearts: Twenty-four patients had a mean age of 53 years (range 38-68, S.D.=8.6). VADs were implanted for 177.8 days (range 7-593 days, S.D.=151.1). Comparison of histologic scores of biopsies with explanted hearts showed the following: CN 1.33 (S.D.=1.4)/0.21 (S.D.=0.66; P<.001); CB: 2.1 (S.D.=0.93)/0.83 (S.D.=0.28; NS); MC: 0.88 (S.D.=1.19)/0.13 (S.D.=0.34; P<.01); IE: 1.71 (S.D.=1.27)/0.38 (S.D.=0.65; NS); fibrosis: 1.08 (S.D.=1

  10. Flow and Compaction During the Vacuum Assisted Resin Transfer Molding Process

    NASA Technical Reports Server (NTRS)

    Grimsley, Brian W.; Hubert, Pascal; Song, Xiao-Lan; Cano, Roberto J.; Loos, Alfred C.; Pipes, R. Byron

    2001-01-01

    The flow of an epoxy resin and compaction behavior of carbon fiber preform during vacuum- assisted resin transfer molding (VARTM) infiltration was measured using an instrumented tool. Composite panels were fabricated by the VARTM process using SAERTEX(R)2 multi-axial non- crimp carbon fiber fabric and the A.T.A.R.D. SI-ZG-5A epoxy resin. Resin pressure and preform thickness variation was measured during infiltration. The effects of the resin on the compaction behavior of the preform were measured. The local preform compaction during the infiltration is a combination of wetting and spring-back deformations. Flow front position computed by the 3DINFIL model was compared with the experimental data.

  11. Real-time polymerase chain reaction analysis of MDM2 and CDK4 expression using total RNA from core-needle biopsies is useful for diagnosing adipocytic tumors

    PubMed Central

    2014-01-01

    Background Diagnosing adipocytic tumors can be challenging because it is often difficult to morphologically distinguish between benign, intermediate and malignant adipocytic tumors, and other sarcomas that are histologically similar. Recently, a number of tumor-specific chromosome translocations and associated fusion genes have been identified in adipocytic tumors and atypical lipomatous tumors/well-differentiated liposarcomas (ALT/WDL), which have a supernumerary ring and/or giant chromosome marker with amplified sequences of the MDM2 and CDK4 genes. The purpose of this study was to investigate whether quantitative real-time polymerase chain reaction (PCR) could be used to amplify MDM2 and CDK4 from total RNA samples obtained from core-needle biopsy sections for the diagnosis of ALT/WDL. Methods A series of lipoma (n = 124) and ALT/WDL (n = 44) cases were analyzed for cytogenetic analysis and lipoma fusion genes, as well as for MDM2 and CDK4 expression by real-time PCR. Moreover, the expression of MDM2 and CDK4 in whole tissue sections was compared with that in core-needle biopsy sections of the same tumor in order to determine whether real-time PCR could be used to distinguish ALT/WDL from lipoma at the preoperative stage. Results In whole tissue sections, the medians for MDM2 and CDK4 expression in ALT/WDL were higher than those in the lipomas (P < 0.05). Moreover, karyotype subdivisions with rings and/or giant chromosomes had higher MDM2 and CDK4 expression levels compared to karyotypes with 12q13-15 rearrangements, other abnormal karyotypes, and normal karyotypes (P < 0.05). On the other hand, MDM2 and CDK4 expression levels in core-needle biopsy sections were similar to those in whole-tissue sections (MDM2: P = 0.6, CDK4: P = 0.8, Wilcoxon signed-rank test). Conclusion Quantitative real-time PCR of total RNA can be used to evaluate the MDM2 and CDK4 expression levels in core-needle biopsies and may be useful for distinguishing ALT

  12. Subsequent Breast Cancer Risk Following Diagnosis of Atypical Ductal Hyperplasia on Needle Biopsy.

    PubMed

    Menes, Tehillah S; Kerlikowske, Karla; Lange, Jane; Jaffer, Shabnam; Rosenberg, Robert; Miglioretti, Diana L

    2017-01-01

    Atypical ductal hyperplasia (ADH) is a known risk factor for breast cancer. Published risk estimates are based on cohorts that included women whose ADH was diagnosed before widespread use of screening mammograms and did not differentiate between the methods used to diagnose ADH, which may be related to the size of the ADH focus. These risks may overestimate the risk in women with presently diagnosed ADH. To examine the risk of invasive cancer associated with ADH diagnosed using core needle biopsy vs excisional biopsy. A cohort study was conducted comparing the 10-year cumulative risk of invasive breast cancer in 955 331 women undergoing mammography with and without a diagnosis of ADH. Data were obtained from 5 breast imaging registries that participate in the National Cancer Institute-funded Breast Cancer Surveillance Consortium. Diagnosis of ADH on core needle biopsy or excisional biopsy in women undergoing mammography. Ten-year cumulative risk of invasive breast cancer. The sample included 955 331 women with 1727 diagnoses of ADH, 1058 (61.3%) of which were diagnosed by core biopsy and 635 (36.8%) by excisional biopsy. The mean (interquartile range) age of the women at diagnosis was 52.6 (46.9-60.4) years. From 1996 to 2012, the proportion of ADH diagnosed by core needle biopsy increased from 21% to 77%. Ten years following a diagnosis of ADH, the cumulative risk of invasive breast cancer was 2.6 (95% CI, 2.0-3.4) times higher than the risk in women with no ADH. Atypical ductal hyperplasia diagnosed via excisional biopsy was associated with an adjusted hazard ratio (HR) of 3.0 (95% CI, 2-4.5) and, via core needle biopsy, with an adjusted HR of 2.2 (95% CI, 1.5-3.4). Ten years after an ADH diagnosis, an estimated 5.7% (95% CI, 4.3%-10.1%) of the women had a diagnosis of invasive cancer. Women with ADH diagnosed on excisional biopsy had a slightly higher risk (6.7%; 95% CI, 3.0%-12.8%) compared with those with ADH diagnosed via core needle biopsy (5%; 95% CI, 2

  13. Composite Properties of RTM370 Polyimide Fabricated by Vacuum Assisted Resin Transfer Molding (VARTM)

    NASA Technical Reports Server (NTRS)

    Chuang, Kathy C.; Criss, James M.; Mintz, Eric A.; Shonkwiler, Brian; McCorkle, Linda S.

    2011-01-01

    RTM370 imide resin based on 2,3,3?,4?-biphenyl dianhydride (a-BPDA), 3,4'-oxydianinline (3,4'-ODA) with the 4-phenylethynylphthalic (PEPA) endcap has been shown to exhibit a high cured T(sub g) (370 C) and low melt viscosity (10-30 poise) at 280 C with a pot-life of 1-2 h. Previously, RTM370 resin has been successfully fabricated into composites reinforced with T650-35 carbon fabrics by resin transfer molding (RTM). RTM370 composites exhibit excellent mechanical properties up to 327?C (620?F), and outstanding property retention after aging at 288?C (550?F) for 1000 h. In this work, RTM370 composites were fabricated by vacuum assisted resin transfer molding (VARTM), using vacuum bags on a steel plate. The mechanical properties of RTM370 composites fabricated by VARTM are compared to those prepared by RTM.

  14. Arthroscopic-assisted core decompression of the humeral head.

    PubMed

    Dines, Joshua S; Strauss, Eric J; Fealy, Stephen; Craig, Edward V

    2007-01-01

    Humeral head osteonecrosis is a progressive disease that requires prompt diagnosis and treatment. Core decompression is a viable treatment option for early-stage cases. Most surgeons perform core decompression by arthroscopically visualizing the necrotic area of bone and using a cannulated drill to take a core. Several attempts are frequently needed to reach the proper location. In the hip multiple passes are associated with complications. We describe the use of an anterior cruciate ligament (ACL) tibial drill guide to precisely localize the area of necrotic bone. Diagnostic arthroscopy is performed to assess the areas of osteonecrosis. Core decompression is performed by use of an ACL tibial guide, brought in through the anterior or posterior portal to precisely localize the necrotic area in preparation for drilling. Under image intensification, Steinmann pins are advanced into the area of osteonecrosis. Once positioned, several 4-mm cores are made. We treated 3 patients with this technique, and all had immediate pain relief. The use of the ACL guide allows precise localization of the area of humeral head involvement and avoids multiple drillings into unaffected areas. Initial indications are that arthroscopic-assisted core decompression with an ACL guide is an effective alternative to previously used methods.

  15. [The evolution of vacuum extraction in obstetrics].

    PubMed

    Nikolov, A

    2010-01-01

    Vacuum extraction is one of the methods for assisted vaginal delivery. In this article the evolution of vacuum extraction in obstetrics is been discussed. Historical facts and data from the invention up to state-of-the-art vacuum systems in modern obstetrics are presented.

  16. Fast 3-T MR-guided transrectal prostate biopsy using an in-room tablet device for needle guide alignment: a feasibility study.

    PubMed

    Overduin, Christiaan G; Heidkamp, Jan; Rothgang, Eva; Barentsz, Jelle O; de Lange, Frank; Fütterer, Jurgen J

    2018-05-22

    To assess the feasibility of adding a tablet device inside the scanner room to assist needle-guide alignment during magnetic resonance (MR)-guided transrectal prostate biopsy. Twenty patients with one cancer-suspicious region (CSR) with PI-RADS score ≥ 4 on diagnostic multiparametric MRI were prospectively enrolled. Two orthogonal scan planes of an MR fluoroscopy sequence (~3 images/s) were aligned to the CSR and needle-guide pivoting point. Targeting was achieved by manipulating the needle-guide under MR fluoroscopy feedback on the in-room tablet device. Technical feasibility and targeting success were assessed. Complications and biopsy procedure times were also recorded. Needle-guide alignment with the in-room tablet device was technically successful in all patients and allowed sampling after a single alignment step in 19/20 (95%) CSRs (median size 14 mm, range: 4-45). Biopsy cores contained cancer in 18/20 patients. There were no per-procedural or post-biopsy complications. Using the tablet device, the mean time to first biopsy was 5.8 ± 1.0 min and the mean total procedure time was 23.7 ± 4.1 min. Use of an in-room tablet device to assist needle-guide alignment was feasible and safe during MR-guided transrectal prostate biopsy. Initial experience indicates potential for procedure time reduction. • Performing MR-guided prostate biopsy using an in-room tablet device is feasible. • CSRs could be sampled after a single alignment step in 19/20 patients. • The mean procedure time for biopsy with the tablet device was 23.7 min.

  17. Homogenate-assisted Vacuum-powered Bubble Extraction of Moso Bamboo Flavonoids for On-line Scavenging Free Radical Capacity Analysis.

    PubMed

    Sun, Yinnan; Yang, Kui; Cao, Qin; Sun, Jinde; Xia, Yu; Wang, Yinhang; Li, Wei; Ma, Chunhui; Liu, Shouxin

    2017-07-11

    A homogenate-assisted vacuum-powered bubble extraction (HVBE) method using ethanol was applied for extraction of flavonoids from Phyllostachys pubescens (P. pubescens) leaves. The mechanisms of homogenate-assisted extraction and vacuum-powered bubble generation were discussed in detail. Furthermore, a method for the rapid determination of flavonoids by HPLC was established. HVBE followed by HPLC was successfully applied for the extraction and quantification of four flavonoids in P. pubescens , including orientin, isoorientin, vitexin, and isovitexin. This method provides a fast and effective means for the preparation and determination of plant active components. Moreover, the on-line antioxidant capacity, including scavenging positive ion and negative ion free radical capacity of different fractions from the bamboo flavonoid extract was evaluated. Results showed that the scavenging DPPH ˙ free radical capacity of vitexin and isovitexin was larger than that of isoorientin and orientin. On the contrary, the scavenging ABTS⁺ ˙ free radical capacity of isoorientin and orientin was larger than that of vitexin and isovitexin.

  18. Rates of upgrade to malignancy for 271 cases of flat epithelial atypia (FEA) diagnosed by breast core biopsy.

    PubMed

    Peres, Alexandre; Barranger, Emmanuel; Becette, Véronique; Boudinet, Alain; Guinebretiere, Jean-Marc; Cherel, Pascal

    2012-06-01

    Flat epithelial atypia (FEA) is a borderline lesion that might represent an early stage in the development of certain low-grade carcinomas in situ and invasive cancers. There are no guidelines on its management. Our objectives were to determine the upgrade to malignancy rate and identify a subpopulation of patients that might undergo just mammographic surveillance. We retrospectively reviewed the data for 271 FEA cases among 5,555 breast core biopsies obtained over a 7-year period (January 2003-2010). We collated clinical data (age, history of cancer, menopausal status), radiological data (lesion type, size, Bi-Rads category), technical data (number of biopsies, needle gauge, excision quality) and histological data and sought correlations between these factors and upgrade rate. The 271 FEA comprised 128 cases of pure FEA, 135 cases of FEA + atypical ductal hyperplasia, and 8 cases of FEA + atypical lobular hyperplasia. Overall, 184 patients underwent surgery and 46 mammographic surveillance. Surgery detected 34 cases of malignancy (23 CIS, 7 invasive cancers, and 4 mixed cases) giving a 15% upgrade rate. Quality of excision was the only factor associated with under-diagnosis. The presence of FEA at biopsy warrants surgery.

  19. Resection of giant right atrial lymphoma using vacuum-assisted cardiopulmonary bypass without snaring the inferior vena cava.

    PubMed

    Shin, Hankei; Mori, Mitsuharu; Matayoshi, Toru; Suzuki, Ryo; Yozu, Ryohei

    2004-08-01

    A 53-year-old man sustained hemodynamic collapse due to a huge right atrial tumor and was transferred to our hospital and underwent a life-saving emergency operation. The tumor arose from the inferolateral wall of the right atrium, occupying almost the whole right atrial cavity and obstructing not only the inflow of the right ventricle but also the orifice of the inferior vena cava. Venous cannulation via the right atrial wall and placing a snare around the inferior vena cava were impossible. With a cardiopulmonary bypass using vacuum-assisted venous drainage, the tumor was successfully resected and the tricuspid valve was replaced with a bioprosthetic valve without snaring the inferior vena cava. Postoperative histological examination demonstrated the tumor to be a large B-cell non-Hodgkin type malignant lymphoma. When the tumor is large and it is difficult to establish total cardiopulmonary bypass, the vacuum-assisted cardiopulmonary bypass is a useful option. This can achieve a bloodless operative field and is not blocked by the incoming air, due to the venous drainage being continually pressure-regulated.

  20. CT Scan-Guided Abrams' Needle Pleural Biopsy versus Ultrasound-Assisted Cutting Needle Pleural Biopsy for Diagnosis in Patients with Pleural Effusion: A Randomized, Controlled Trial.

    PubMed

    Metintas, Muzaffer; Yildirim, Huseyin; Kaya, Tamer; Ak, Guntulu; Dundar, Emine; Ozkan, Ragip; Metintas, Selma

    2016-01-01

    Image-guided pleural biopsies, both using ultrasound (US) or computed tomography (CT), are important in the diagnosis of pleural disease. However, no consensus exists regarding which biopsy needles are appropriate for specific procedures. In this randomized, prospective study, we aimed to compare CT scan-guided pleural biopsy using an Abrams' needle (CT-ANPB) with US-assisted pleural biopsy using a cutting needle (US-CNPB) with respect to both diagnostic yield and safety. Between February 2009 and April 2013, 150 patients with exudative pleural effusion who could not be diagnosed by cytological analysis were included in the study. The patients were randomized into either the US-CNPB group or the CT-ANPB group. The two groups were compared in terms of diagnostic sensitivity and complications. Of the 150 patients enrolled in this study, 45 were diagnosed with malignant mesothelioma, 46 were diagnosed with metastatic pleural disease, 18 were diagnosed with pleural tuberculosis, 34 were diagnosed with benign pleural disease, and 7 were lost to follow-up. In the US-CNPB group, the diagnostic sensitivity was 66.7%, compared with 82.4% in the CT-ANPB group; the difference between the two groups was statistically significant (p = 0.029). The sensitivity of CT-ANPB increased to 93.7% for patients with a pleural thickness ≥1 cm. The complication rates were low and acceptable. The first diagnostic intervention that should be preferred in patients with pleural effusion and associated pleural thickening on a CT scan is CT-ANPB. US-CNPB should be used primarily in cases for which only pleural thickening but no pleural effusion is noted. © 2016 S. Karger AG, Basel.

  1. Mondor's disease of the breast as a complication of ultrasound-guided core needle biopsy: management and review of the literature.

    PubMed

    Salemis, Nikolaos S; Vasilara, Georgia; Lagoudianakis, Emmanuel

    2015-01-01

    Mondor's disease is a rare benign and self-limiting condition characterized by thrombophlebitis of the superficial veins of the anterolateral thoracoabdominal wall. We describe a case of Mondor's disease of the breast as a complication of an ultrasound-guided core needle biospy. The patient presented with a palpable cord-like structure in her left breast, associated with severe pain and tenderness. She was treated concervatively and complete resolution was observed after four weeks. We conclude that emergency clinicians and interventional breast radiologists should be aware of Mondor's disease as a potential complication of ultrasound-guided core needle biopsy of the breast.

  2. Subsequent Breast Cancer Risk Following Diagnosis of Atypical Ductal Hyperplasia on Needle Biopsy

    PubMed Central

    Menes, Tehillah S; Kerlikowske, Karla; Lange, Jane; Jaffer, Shabnam; Rosenberg, Robert; Miglioretti, Diana L.

    2017-01-01

    Background Atypical ductal hyperplasia (ADH) is a known strong risk factor for breast cancer. Published risk estimates are based on cohorts that included women diagnosed prior to the widespread use of screening mammograms and do not differentiate between the methods used to diagnose ADH, which may be related to size of the ADH focus. These risks may overestimate the risk of women currently diagnosed with ADH. We sought to examine the risk of invasive cancer associated with ADH diagnosed on core needle biopsy versus excisional biopsy. Design Cohort study comparing ten-year cumulative risk of invasive breast cancer in women undergoing mammography with and without a diagnosis of ADH. Setting Five breast imaging registries that participate in the National Cancer Institute–funded Breast Cancer Surveillance Consortium (BCSC). Participants Women undergoing mammography in the BCSC. Exposure Diagnosis of ADH on core needle biopsy or excisional biopsy in women undergoing mammography. Main outcome Ten-year cumulative risk of invasive breast cancer risk. Results The sample included 955,331 women with 1,727 diagnoses of ADH. From 1996 to 2012, the proportion of ADH diagnosed by core needle biopsy increased from 21% to 77%. Ten years following a diagnosis of ADH, the cumulative risk of invasive breast cancer was 2.6 (95% CI 2.0, 3.4) times higher than risk in women with no ADH. ADH diagnosed via excisional biopsy was associated with an adjusted HR of 3.0 (95% CI 2.0, 4.5), and via core needle biopsy, with an HR of 2.2 (95% CI 1.5, 3.4). Ten years after an ADH diagnosis, an estimated 5.7% (95% CI 4.3, 10.1) of women were diagnosed with invasive cancer. Women with ADH diagnosed on excisional biopsy had a slightly higher risk (6.7 %; 95% CI 3.0, 12.8) compared to those with ADH diagnosed via core needle biopsy (5.0%; 95% CI 2.2, 8.9). Conclusions Current 10-year risks of invasive breast cancer after a diagnosis of ADH may be lower than previously reported. The risk associated

  3. Cognitive versus Software-Assisted Registration: Development of a New Nomogram Predicting Prostate Cancer at MRI-Targeted Biopsies.

    PubMed

    Kaufmann, Sascha; Russo, Giorgio I; Thaiss, Wolfgang; Notohamiprodjo, Mike; Bamberg, Fabian; Bedke, Jens; Morgia, Giuseppe; Nikolaou, Konstantin; Stenzl, Arnulf; Kruck, Stephan

    2018-04-03

    Multiparametric magnetic resonance imaging (mpMRI) is gaining acceptance to guide targeted biopsy (TB) in prostate cancer (PC) diagnosis. We aimed to compare the detection rate of software-assisted fusion TB (SA-TB) versus cognitive fusion TB (COG-TB) for PC and to evaluate potential clinical features in detecting PC and clinically significant PC (csPC) at TB. This was a retrospective cohort study of patients with rising and/or persistently elevated prostate-specific antigen (PSA) undergoing mpMRI followed by either transperineal SA-TB or transrectal COG-TB. The analysis showed a matched-paired analysis between SA-TB versus COG-TB without differences in clinical or radiological characteristics. Differences among detection of PC/csPC among groups were analyzed. A multivariable logistic regression model predicting PC at TB was fitted. The model was evaluated using the receiver operating characteristic-derived area under the curve, goodness of fit test, and decision-curve analyses. One hundred ninety-one and 87 patients underwent SA-TB or COG-TB, respectively. The multivariate logistic analysis showed that SA-TB was associated with overall PC (odds ratio [OR], 5.70; P < .01) and PC at TB (OR, 3.00; P < .01) but not with overall csPC (P = .40) and csPC at TB (P = .40). A nomogram predicting PC at TB was constructed using the Prostate Imaging Reporting and Data System version 2.0, age, PSA density and biopsy technique, showing improved clinical risk prediction against a threshold probability of 10% with a c-index of 0.83. In patients with suspected PC, software-assisted biopsy detects most cancers and outperforms the cognitive approach in targeting magnetic resonance imaging-visible lesions. Furthermore, we introduced a prebiopsy nomogram for the probability of PC in TB. Copyright © 2018 Elsevier Inc. All rights reserved.

  4. MRI-Targeted or Standard Biopsy for Prostate-Cancer Diagnosis.

    PubMed

    Kasivisvanathan, Veeru; Rannikko, Antti S; Borghi, Marcelo; Panebianco, Valeria; Mynderse, Lance A; Vaarala, Markku H; Briganti, Alberto; Budäus, Lars; Hellawell, Giles; Hindley, Richard G; Roobol, Monique J; Eggener, Scott; Ghei, Maneesh; Villers, Arnauld; Bladou, Franck; Villeirs, Geert M; Virdi, Jaspal; Boxler, Silvan; Robert, Grégoire; Singh, Paras B; Venderink, Wulphert; Hadaschik, Boris A; Ruffion, Alain; Hu, Jim C; Margolis, Daniel; Crouzet, Sébastien; Klotz, Laurence; Taneja, Samir S; Pinto, Peter; Gill, Inderbir; Allen, Clare; Giganti, Francesco; Freeman, Alex; Morris, Stephen; Punwani, Shonit; Williams, Norman R; Brew-Graves, Chris; Deeks, Jonathan; Takwoingi, Yemisi; Emberton, Mark; Moore, Caroline M

    2018-05-10

    Multiparametric magnetic resonance imaging (MRI), with or without targeted biopsy, is an alternative to standard transrectal ultrasonography-guided biopsy for prostate-cancer detection in men with a raised prostate-specific antigen level who have not undergone biopsy. However, comparative evidence is limited. In a multicenter, randomized, noninferiority trial, we assigned men with a clinical suspicion of prostate cancer who had not undergone biopsy previously to undergo MRI, with or without targeted biopsy, or standard transrectal ultrasonography-guided biopsy. Men in the MRI-targeted biopsy group underwent a targeted biopsy (without standard biopsy cores) if the MRI was suggestive of prostate cancer; men whose MRI results were not suggestive of prostate cancer were not offered biopsy. Standard biopsy was a 10-to-12-core, transrectal ultrasonography-guided biopsy. The primary outcome was the proportion of men who received a diagnosis of clinically significant cancer. Secondary outcomes included the proportion of men who received a diagnosis of clinically insignificant cancer. A total of 500 men underwent randomization. In the MRI-targeted biopsy group, 71 of 252 men (28%) had MRI results that were not suggestive of prostate cancer, so they did not undergo biopsy. Clinically significant cancer was detected in 95 men (38%) in the MRI-targeted biopsy group, as compared with 64 of 248 (26%) in the standard-biopsy group (adjusted difference, 12 percentage points; 95% confidence interval [CI], 4 to 20; P=0.005). MRI, with or without targeted biopsy, was noninferior to standard biopsy, and the 95% confidence interval indicated the superiority of this strategy over standard biopsy. Fewer men in the MRI-targeted biopsy group than in the standard-biopsy group received a diagnosis of clinically insignificant cancer (adjusted difference, -13 percentage points; 95% CI, -19 to -7; P<0.001). The use of risk assessment with MRI before biopsy and MRI-targeted biopsy was superior to

  5. Core Needle Biopsy of the Thyroid: 2016 Consensus Statement and Recommendations from Korean Society of Thyroid Radiology

    PubMed Central

    Na, Dong Gyu; Jung, So Lyung; Kim, Ji-hoon; Sung, Jin Yong; Kim, Kyu Sun; Lee, Jeong Hyun; Shin, Jung Hee; Choi, Yoon Jung; Ha, Eun Ju; Lim, Hyun Kyung; Kim, Soo Jin; Hahn, Soo Yeon; Lee, Kwang Hwi; Choi, Young Jun; Youn, Inyoung; Kim, Young Joong; Ahn, Hye Shin; Ryu, Ji Hwa; Baek, Seon Mi; Sim, Jung Suk; Jung, Chan Kwon; Lee, Joon Hyung

    2017-01-01

    Core needle biopsy (CNB) has been suggested as a complementary diagnostic method to fine-needle aspiration in patients with thyroid nodules. Many recent CNB studies have suggested a more advanced role for CNB, but there are still no guidelines on its use. Therefore, the Task Force Committee of the Korean Society of Thyroid Radiology has developed the present consensus statement and recommendations for the role of CNB in the diagnosis of thyroid nodules. These recommendations are based on evidence from the current literature and expert consensus. PMID:28096731

  6. Regular transition zone biopsy during active surveillance for prostate cancer may improve detection of pathological progression.

    PubMed

    Wong, Lih-Ming; Toi, Ants; Van der Kwast, Theodorus; Trottier, Greg; Alibhai, Shabbir M H; Timilshina, Narhari; Evans, Andrew; Zlotta, Alexandre; Fleshner, Neil; Finelli, Antonio

    2014-10-01

    We investigated the frequency of cancer and pathological progression in transition zone biopsies in men undergoing multiple rebiopsies while on active surveillance. Eligibility criteria of the active surveillance prostate cancer database (1997 to 2012) at our tertiary center includes prostate specific antigen 10 ng/ml or less, cT2 or less, no Gleason grade 4 or 5, 3 or fewer positive cores, no core with greater than 50% involvement, patient age 75 years or less and 1 or more biopsies after initial diagnostic biopsy. We excluded from analysis men with fewer than 10 cores at diagnostic biopsy and/or confirmatory biopsy greater than 24 months after diagnostic biopsy. Multiparametric magnetic resonance imaging was performed selectively to investigate incongruity between prostate specific antigen and biopsy findings. Pathological progression was defined by grade and/or volume (greater than 50% of core involved). Transition zone progression was subdivided into exclusively transition zone and combined transition zone (transition and peripheral zones). A multivariate Cox proportional hazards model was used to determine predictors of transition zone progression. A total of 392 men were considered in analysis. Median followup was 45.5 months. At each biopsy during active surveillance (confirmatory biopsy to biopsy 5+) there were transition zone positive cores in 18.6% to 26.7% of cases, all transition zone progression in 5.9% to 11.1% and exclusively transition zone progression in 2.7% to 6.7%. Volume related progression was noted more frequently than grade related progression (24 vs 9 cases). Predictors of only transition zone progression were the maximum percent in a single core (HR 1.99, 95% CI 1.30-3.04, p = 0.002) and cancer on magnetic resonance imaging (HR 3.19, 95% CI 1.23-8.27, p = 0.02). Across multiple active surveillance biopsies 2.7% to 6.7% of men had only transition zone progression. We recommend that transition zone biopsy be considered in all men at

  7. An effective vacuum assisted extraction method for the optimization of labdane diterpenoids from Andrographis paniculata by response surface methodology.

    PubMed

    Wang, Ya-Qi; Wu, Zhen-Feng; Ke, Gang; Yang, Ming

    2014-12-31

    An effective vacuum assisted extraction (VAE) technique was proposed for the first time and applied to extract bioactive components from Andrographis paniculata. The process was carefully optimized by response surface methodology (RSM). Under the optimized experimental conditions, the best results were obtained using a boiling temperature of 65 °C, 50% ethanol concentration, 16 min of extraction time, one extraction cycles and a 12:1 liquid-solid ratio. Compared with conventional ultrasonic assisted extraction and heat reflux extraction, the VAE technique gave shorter extraction times and remarkable higher extraction efficiency, which indicated that a certain degree of vacuum gave the solvent a better penetration of the solvent into the pores and between the matrix particles, and enhanced the process of mass transfer. The present results demonstrated that VAE is an efficient, simple and fast method for extracting bioactive components from A. paniculata, which shows great potential for becoming an alternative technique for industrial scale-up applications.

  8. Flat epithelial atypia is a common subtype of B3 breast lesions and is associated with noninvasive cancer but not with invasive cancer in final excision histology.

    PubMed

    Noske, Aurelia; Pahl, Stefan; Fallenberg, Eva; Richter-Ehrenstein, Christiane; Buckendahl, Ann-Christin; Weichert, Wilko; Schneider, Achim; Dietel, Manfred; Denkert, Carsten

    2010-04-01

    The biological behavior and the optimal management of benign breast lesions with uncertain malignant potential, the so-called B3 lesions, found in breast needle core biopsies is still under debate. We addressed this study to compare histologic findings in B3 needle core biopsies with final excision specimens to determine associated rates of malignancy. Consecutive needle core biopsies were performed in a 3-year period (January 1, 2006-December 31, 2008). Biopsies were image-guided (31 by ultrasound, 85 stereotactic vacuum-assisted, 6 unknown) for evaluation of breast abnormalities. We reviewed 122 needle core biopsies with B3 lesions of 91 symptomatic patients and 31 screen-detected women and compared the B3 histologic subtypes with the final excision histology. A total of 1845 needle core biopsies were performed and B3 lesions comprised 6.6% of all B categories. The most common histologic subtype in biopsies was flat epithelia atypia in 35.2%, followed by papillary lesions in 21% and atypical ductal hyperplasia in 20%. Reports on excision specimens were available in 66% (81 patients). Final excision histology was benign in 73 (90.2%) and malignant in 8 (9.8%) patients (2 invasive cancer, 6 ductal carcinoma in situ). Of all B3 subtypes, atypical ductal hyperplasia and flat epithelial atypia were associated with malignancy, whereas only atypical ductal hyperplasia was accompanied by invasive cancer. Of all lesions, flat epithelial atypia was most frequently found in excision specimens (18%). In our study, flat epithelial atypia and atypical ductal hyperplasia are common lesions of the B3 category in needle core biopsies of the breast. Both lesions are associated with malignancy, whereas only atypical ductal hyperplasia was related to invasive cancer. We conclude that an excision biopsy after diagnosis of flat epithelial atypia is recommended depending on clinical and radiologic findings. Copyright 2010 Elsevier Inc.

  9. Stiffness at shear-wave elastography and patient presentation predicts upgrade at surgery following an ultrasound-guided core biopsy diagnosis of ductal carcinoma in situ.

    PubMed

    Evans, A; Purdie, C A; Jordan, L; Macaskill, E J; Flynn, J; Vinnicombe, S

    2016-11-01

    The aim of this study is to establish predictors of invasion in lesions yielding an ultrasound-guided biopsy diagnosis of ductal carcinoma in situ (DCIS). Patients subjected to ultrasound-guided core biopsy yielding DCIS were studied. At shear-wave elastography (SWE) a threshold of 50 kPa was used for mean elasticity (Emean) to dichotomise the elasticity data between invasive and non-invasive masses. Data recorded included the mammographic and ultrasound features, the referral source, and grade of DCIS in the biopsy. The chi-square test was used to detect statistical significance. Of 57 lesions, 24 (42%) had invasion at excision. Symptomatic patients and patients with stiff lesions were more likely to have invasion than patients presenting through screening and with soft lesions (58% [14 of 24] versus 30% [10 of 33], p=0.03) and (51% [20 of 39] versus 22% [4 of 18], p=0.04). No other factors showed a relationship with invasion. Combining the two predictors of invasion improved risk stratification with symptomatic and stiff lesions having a risk of invasion of 67% (12 of 18) and soft lesions presenting at screening having only a 17% (2 of 12) risk of invasion (p=0.02). Stiffness on SWE and the referral source of the patient are predictors of occult invasion in women with an ultrasound-guided core biopsy diagnosis of DCIS. Copyright © 2016 The Royal College of Radiologists. Published by Elsevier Ltd. All rights reserved.

  10. High-frequency ultrasound imaging for breast cancer biopsy guidance

    PubMed Central

    Cummins, Thomas; Yoon, Changhan; Choi, Hojong; Eliahoo, Payam; Kim, Hyung Ham; Yamashita, Mary W.; Hovanessian-Larsen, Linda J.; Lang, Julie E.; Sener, Stephen F.; Vallone, John; Martin, Sue E.; Kirk Shung, K.

    2015-01-01

    Abstract. Image-guided core needle biopsy is the current gold standard for breast cancer diagnosis. Microcalcifications, an important radiographic finding on mammography suggestive of early breast cancer such as ductal carcinoma in situ, are usually biopsied under stereotactic guidance. This procedure, however, is uncomfortable for patients and requires the use of ionizing radiation. It would be preferable to biopsy microcalcifications under ultrasound guidance since it is a faster procedure, more comfortable for the patient, and requires no radiation. However, microcalcifications cannot reliably be detected with the current standard ultrasound imaging systems. This study is motivated by the clinical need for real-time high-resolution ultrasound imaging of microcalcifications, so that biopsies can be accurately performed under ultrasound guidance. We have investigated how high-frequency ultrasound imaging can enable visualization of microstructures in ex vivo breast tissue biopsy samples. We generated B-mode images of breast tissue and applied the Nakagami filtering technique to help refine image output so that microcalcifications could be better assessed during ultrasound-guided core biopsies. We describe the preliminary clinical results of high-frequency ultrasound imaging of ex vivo breast biopsy tissue with microcalcifications and without Nakagami filtering and the correlation of these images with the pathology examination by hematoxylin and eosin stain and whole slide digital scanning. PMID:26693167

  11. Diagnosis of Metastasis to the Thyroid Gland: Comparison of Core-Needle Biopsy and Fine-Needle Aspiration.

    PubMed

    Choi, Sang Hyun; Baek, Jung Hwan; Ha, Eun Ju; Choi, Young Jun; Song, Dong Eun; Kim, Jae Kyun; Chung, Ki-Wook; Kim, Tae Yong; Lee, Jeong Hyun

    2016-04-01

    Early detection and diagnosis of metastasis to the thyroid gland is important. This study aims to evaluate the clinical value of core-needle biopsy (CNB) by comparing the results of CNB and fine-needle aspiration (FNA) in patients with clinically suspected metastasis to the thyroid gland. Case series with chart review. Tertiary referral practice. Fifty-two thyroid nodules from 52 patients with clinically suspected metastasis to the thyroid gland (mean age, 62.8 years). Of these 52 patients, FNA was initially used in 41 patients and CNB in 20 patients (11 patients as the initial approach and 9 patients after inconclusive FNA results). Ultrasound features of metastasis to the thyroid gland were evaluated. The diagnostic performance, repeated diagnostic examination rate, and diagnostic surgery rate were evaluated for FNA and CNB. Among these 52 patients, 46 were diagnosed with thyroid metastases and 6 were diagnosed with primary thyroid cancer. Common ultrasound features were an ovoid to round shape (58.7%), ill-defined margin (56.5%), hypoechogenicity (65.2%), and no calcifications (87.0%). Core-needle biopsy achieved a significantly higher sensitivity than FNA (100.0% vs 58.6%, P = .008) without any false-negative results. Both the repeated diagnostic examination rate and the diagnostic surgery rate were significantly lower in CNB than in FNA (5.0% vs 46.3%, P = .001, and 5.0% vs 34.1%, P = .013, respectively). In cases of known rare primary malignancy, nontypical ultrasound features of primary thyroid malignancy, and need for an additional immunohistochemical analysis, CNB may be primarily considered. © American Academy of Otolaryngology—Head and Neck Surgery Foundation 2016.

  12. Flat epithelial atypia of the breast on core needle biopsy: an indication for surgical excision.

    PubMed

    Sohn, Vance; Porta, Rees; Brown, Tommy

    2011-11-01

    Flat epithelial atypia (FEA) is an increasingly diagnosed breast lesion yet there remains a paucity of data regarding these findings and their clinical significance. By determining the pathologic concordance rate, we sought to evaluate the indications for surgical intervention for FEAs diagnosed on core needle biopsy (CNB). Using a retrospective review of an international pathology referral center database, we included all breast CNB specimens with FEA as the most advanced diagnosis that underwent surgical excision. Patient demographics, caliber of biopsy needle, and pathology results were then analyzed. Between 2000 and 2009, 463 FEAs were diagnosed among 15,000 specimens referred for expert opinion. Twenty-four lesions (5%) met inclusion criteria. Sampling ranged from 8- to 18-guage needles. Two lesions (8.4%) were upgraded after surgical excision; one patient was found to have infiltrating ductal carcinoma and another with tubular carcinoma. Twelve patients who were diagnosed with FEA did not undergo surgical excision but had no immediate evidence of malignancy. Based on the 8.4% upgrade rate, FEA diagnosed on CNB requires follow-up surgical excision. Regardless of CNB caliber, the risk of sampling error precludes nonoperative management and FEA should be considered an at-risk lesion until more studies and pooled analysis prove otherwise.

  13. Biliary plastic stent does not influence the accuracy of endoscopic ultrasound-guided sampling of pancreatic head masses performed with core biopsy needles.

    PubMed

    Antonini, Filippo; Fuccio, Lorenzo; Giorgini, Sara; Fabbri, Carlo; Frazzoni, Leonardo; Scarpelli, Marina; Macarri, Giampiero

    2017-08-01

    While the presence of biliary stent significantly decreases the accuracy of endoscopic ultrasound (EUS) for pancreatic head cancer staging, its impact on the EUS-guided sampling accuracy is still debated. Furthermore, data on EUS-fine needle biopsy (EUS-FNB) using core biopsy needles in patients with pancreatic mass and biliary stent are lacking. The aim of this study was to evaluate the influence of biliary stent on the adequacy and accuracy of EUS-FNB in patients with pancreatic head mass. All patients who underwent EUS-guided sampling with core needles of solid pancreatic head masses causing obstructive jaundice were retrospectively identified in a single tertiary referral center. Adequacy, defined as the rate of cases in which a tissue specimen for proper examination was achieved, with and without biliary stent, was the primary outcome measure. The diagnostic accuracy and complication rate were the secondary outcome measures. A total of 130 patients with pancreatic head mass causing biliary obstruction were included in the study: 74 cases of them were sampled without stent and 56 cases with plastic stent in situ. The adequacy was 96.4% in the stent group and 90.5% in the group without stent (p=0.190). No significant differences were observed for sensitivity (88.9% vs. 85.9%), specificity (100% for both groups), and accuracy (89.3% vs. 86.5%) between those with and without stent, respectively. The accuracy was not influenced by the timing of stenting (<48h or ≥48h before EUS). No EUS-FNB related complications were recorded. The presence of biliary stent does not influence the tissue sampling adequacy, the diagnostic accuracy and the complication rate of EUS-FNB of pancreatic head masses performed with core biopsy needles. Copyright © 2017 Editrice Gastroenterologica Italiana S.r.l. Published by Elsevier Ltd. All rights reserved.

  14. The cost-effectiveness of fine-needle aspiration cytology and 14-gauge core needle biopsy compared with open surgical biopsy in the diagnosis of breast carcinoma.

    PubMed

    Logan-Young, W; Dawson, A E; Wilbur, D C; Avila, E E; Tomkiewicz, Z M; Sheils, L A; Laczin, J A; Taylor, A S

    1998-05-15

    Judicious utilization of fine-needle aspiration cytology (FNAC) and 14-gauge core needle biopsy (CB) theoretically should result in greater accuracy in breast carcinoma diagnosis and fewer unnecessary open surgical biopsies (OSBs), thus lowering health care costs. In 1995 in Rochester, New York, the ratio of open surgical breast biopsies per each verified breast carcinoma (OSB/Ca) in a freestanding breast clinic (EWBC) was compared with the OSB/Ca ratio of all physicians in the remainder of the city. The EWBC differs from all other diagnostic facilities in Rochester in that it routinely performs FNAC and CB. The EWBC recommended 462 OSBs resulting in 310 verified carcinomas, for a OSB/Ca ratio of 1.5. The physicians in the remainder of the city recommended 2036 OSBs resulting in 513 verified carcinomas, for a OSB/Ca ratio of 4.0. If the EWBC OSB/Ca ratio had been identical to the remainder of the city, the number of extra OSBs recommended by the clinic would have been 778, resulting in an additional cost of $1,712,082. When the added cost of the 2594 FNACs ($256,285) and 403 CBs ($252,278) performed by the clinic was subtracted from the $1,712,082, the freestanding breast clinic cost savings was $1,203,519. The lymph node metastasis rate of 19% for the breast carcinomas diagnosed in clinic patients was identical to that of the women with breast carcinoma in the remainder of the city. Utilization of FNAC and CB allows radiologists to lower their OSB/Ca ratio without sacrificing early detection. In this study, these less expensive procedures result in lowered medical costs for the health care system.

  15. Impact of extended prostate biopsy including apical anterior region for cancer detection and prediction of surgical margin status for radical prostatectomy.

    PubMed

    Hashimoto, Kohei; Shinkai, Nobuo; Tanaka, Toshiaki; Masumori, Naoya

    2017-06-01

    We investigated diagnostic yield of initial biopsy and repeated biopsy including apical cores. We investigated 573 consecutive men with PSA of ≤20 ng/ml who underwent prostate biopsy between 2004 and 2013. The initial 14-core biopsy consisted of the sextant type, lateral sites at the base and middle, lateral apices (la) at anterior horn sites, and apical anterior sites (aa). The repeated 18-core biopsy consisted of the initial 14-core biopsy with four transition zone (TZ) sites at the base (tzb) and middle (tzm). Prostate cancer was diagnosed in 178 (38.9%) of 458 men with the initial 14-core biopsy, and 44 (38.3%) of 115 men with the repeated 18-core biopsy. In the initial biopsy setting, the unique cancer detection rate was high in apical sites (apex, la, and aa: 6.2%, 6.2% and 5.1%, respectively). In the repeated setting, it was high in the TZ site in addition to the apical site (apex, la, aa, tzm, and tzb: 6.8%, 6.8%, 11.4%, 9.1% and 11.4%, respectively). The positive SM rate at the apex was higher in patients whose cancer was detected only in sites other than the sextant region than for those in the sextant region (36.4% vs. 14.8%, P = 0.037). The initial 14-core and the repeated 18-core biopsy scheme including apical anterior cores are feasible for prostate cancer detection. We propose that apical biopsy cores can be used to predict not only the existence of cancer but also surgical margin status at the apex. © The Author 2017. Published by Oxford University Press. All rights reserved. For permissions, please e-mail: journals.permissions@oup.com.

  16. Integrated Cooling-Vacuum-Assisted Non-Fractional 1540 nm Erbium:Glass Laser is Effective in Treating Acne Scars.

    PubMed

    Politi, Yael; Levi, Assi; Lapidoth, Moshe

    2016-11-01

    Acne scars are a common result of in ammatory acne, affecting many patients worldwide. Among which, atrophic scars are the most prevalent form, presenting as dermal depressions caused by inflammatory degeneration of dermal collagen. Mid-infrared laser skin interaction is characterized by its modest absorption in water and nite penetration to the mid-dermis. Since collagen is a desirable laser target, 1540-nm wavelength is amenable for collagen remodeling within the depressed area of atrophic scars. To evaluate the safety and efficacy of acne scars treatment using an integrated cooling-vacuum-assisted 1540 nm Erbium: Glass Laser. This interventional prospective study included 25 volunteers (10 men, 15 women) with post acne atrophic scars. Patients were treated with a mid-infrared non-fractional 1540 nm Er:Glass laser (Alma Lasers Ltd. Caesarea, Israel) with integrat- ed cooling- vacuum assisted technology. Acne scars were exposed to 3 stacked laser pulses (400-600 mJ/pulse, 4 mm spot size, frequency of 3 Hz). Patients underwent 3-6 treatment sessions with a 2-3 week interval and were followed-up 1 month and 3 months after the last treatment. Clinical photographs were taken by high resolution digital camera before and after treatment. Clinical evaluation was performed by two independent dermatologists and results were graded on a scale of 0 (exacerbation) to 4 (76%-100% improvement). Patients' and physicians' satisfaction were also recorded (on a 1-5 scale). Pain perception and adverse effects were evaluated as well. Almost all patients (24/25) demonstrated a moderate to significant improvement. Average improvement was 3.9 and 4.1 points on the quartile scale used for outcome assessment 1 and 3 months following the last session, respectively. Patient satisfaction rate was 4.2. Side effects were minimal and transient: erythema, mild transient vesicles, and mild pain or inconvenience. CONCLUSION Cooling-Vacuum-Assisted mid-infrared non-fractional Er:Glass 1540 nm laser

  17. Utilization of sentinel lymph node biopsy for uterine cancer.

    PubMed

    Wright, Jason D; Cham, Stephanie; Chen, Ling; Burke, William M; Hou, June Y; Tergas, Ana I; Desai, Vrunda; Hu, Jim C; Ananth, Cande V; Neugut, Alfred I; Hershman, Dawn L

    2017-06-01

    To limit the potential short and long-term morbidity of lymphadenectomy, sentinel lymph node biopsy has been proposed for endometrial cancer. The principle of sentinel lymph node biopsy relies on removal of a small number of lymph nodes that are the first drainage basins from a tumor and thus the most likely to harbor tumor cells. While the procedure may reduce morbidity, efficacy data are limited and little is known about how commonly the procedure is performed. We examined the patterns and predictors of use of sentinel lymph node biopsy and outcomes of the procedure in women with endometrial cancer who underwent hysterectomy. We used the Perspective database to identify women with uterine cancer who underwent hysterectomy from 2011 through 2015. Billing and charge codes were used to classify women as having undergone lymphadenectomy, sentinel lymph node biopsy, or no nodal assessment. Multivariable models were used to examine clinical, demographic, and hospital characteristics with use of sentinel lymph node biopsy. Length of stay and cost were compared among the different methods of nodal assessment. Among 28,362 patients, 9327 (32.9%) did not undergo nodal assessment, 17,669 (62.3%) underwent lymphadenectomy, and 1366 (4.8%) underwent sentinel lymph node biopsy. Sentinel lymph node biopsy was performed in 1.3% (95% confidence interval, 1.0-1.6%) of abdominal hysterectomies, 3.4% (95% confidence interval, 2.7-4.1%) of laparoscopic hysterectomies, and 7.5% (95% confidence interval, 7.0-8.0%) of robotic-assisted hysterectomies. In a multivariable model, more recent year of surgery was associated with performance of sentinel lymph node biopsy. Compared to abdominal hysterectomy, those undergoing laparoscopic (adjusted risk ratio, 2.45; 95% confidence interval, 1.89-3.18) and robotic-assisted (adjusted risk ratio, 2.69; 95% confidence interval, 2.19-3.30) hysterectomy were more likely to undergo sentinel lymph node biopsy. Among women who underwent minimally

  18. The liquid biopsy in lung cancer.

    PubMed

    Ansari, Junaid; Yun, Jungmi W; Kompelli, Anvesh R; Moufarrej, Youmna E; Alexander, Jonathan S; Herrera, Guillermo A; Shackelford, Rodney E

    2016-11-01

    The incidence of lung cancer has significantly increased over the last century, largely due to smoking, and remains the most common cause of cancer deaths worldwide. This is often due to lung cancer first presenting at late stages and a lack of curative therapeutic options at these later stages. Delayed diagnoses, inadequate tumor sampling, and lung cancer misdiagnoses are also not uncommon due to the limitations of the tissue biopsy. Our better understanding of the tumor microenvironment and the systemic actions of tumors, combined with the recent advent of the liquid biopsy, may allow molecular diagnostics to be done on circulating tumor markers, particularly circulating tumor DNA. Multiple liquid biopsy molecular methods are presently being examined to determine their efficacy as surrogates to the tumor tissue biopsy. This review will focus on new liquid biopsy technologies and how they may assist in lung cancer detection, diagnosis, and treatment.

  19. Magnet Assisted Composite Manufacturing: A Flexible New Technique for Achieving High Consolidation Pressure in Vacuum Bag/Lay-Up Processes.

    PubMed

    Pishvar, Maya; Amirkhosravi, Mehrad; Altan, M Cengiz

    2018-05-17

    This work demonstrates a protocol to improve the quality of composite laminates fabricated by wet lay-up vacuum bag processes using the recently developed magnet assisted composite manufacturing (MACM) technique. In this technique, permanent magnets are utilized to apply a sufficiently high consolidation pressure during the curing stage. To enhance the intensity of the magnetic field, and thus, to increase the magnetic compaction pressure, the magnets are placed on a magnetic top plate. First, the entire procedure of preparing the composite lay-up on a magnetic bottom steel plate using the conventional wet lay-up vacuum bag process is described. Second, placement of a set of Neodymium-Iron-Boron permanent magnets, arranged in alternating polarity, on the vacuum bag is illustrated. Next, the experimental procedures to measure the magnetic compaction pressure and volume fractions of the composite constituents are presented. Finally, methods used to characterize microstructure and mechanical properties of composite laminates are discussed in detail. The results prove the effectiveness of the MACM method in improving the quality of wet lay-up vacuum bag laminates. This method does not require large capital investment for tooling or equipment and can also be used to consolidate geometrically complex composite parts by placing the magnets on a matching top mold positioned on the vacuum bag.

  20. Prospective, Randomized, Pathologist-Blinded Study of Disposable Alligator-Jaw Biopsy Forceps for Gastric Mucosal Biopsy

    PubMed Central

    Abudayyeh, Suhaib; Hoffman, Jill; El-Zimaity, Hala T.; Graham, David Y.

    2010-01-01

    Background Endoscopic biopsy forceps differ in the size and shape of the biopsy cup and the presence or absence of a needle. Methods We compared 4 different “large cup” forceps (3 with needles designed for 2.8 mm biopsy channels. A gastric antral and corpus biopsy were obtained with each. Parameters examined included: weight (mg), length (mm), orientation (poor, good), intactness (1, 2, or 3 pieces), depth (superficial, above muscularis mucosae, included muscularis mucosae), crush artifact (yes, no), and overall adequacy (inadequate, suboptimal, adequate). Results 24 patients were enrolled (191 biopsies). The median length was approximately 5 mm (range 1.1 to 8.2 mm). Histologically inadequate specimens were present in 4% with the forceps without needle compared to 16% of those with needles (P = 0.061) and there were significantly fewer specimens in 3 or more pieces than did the forceps with needles 2.1% vs. 12..6% (P<0.05). Conclusions Current alligator style forceps provide a high proportion of acceptable specimens with only minor differences between brands. Forceps from one source were least preferred by endoscopy assistants and had the highest rates of inadequate biopsies and biopsies with crush artifact. Forceps without needles provide histologically acceptable samples slightly more frequently than those with needles. PMID:18799373

  1. Prospective, randomized, pathologist-blinded study of disposable alligator-jaw biopsy forceps for gastric mucosal biopsy.

    PubMed

    Abudayyeh, S; Hoffman, J; El-Zimaity, H T; Graham, D Y

    2009-05-01

    Endoscopic biopsy forceps differ in the size and shape of the biopsy cup and the presence or absence of a needle. We compared four different "large cup" forceps (three with needles) designed for 2.8mm biopsy channels. A gastric antral and corpus biopsy were obtained with each. Parameters examined included: weight (mg), length (mm), orientation (poor, good), intactness (1, 2, or 3 pieces), depth (superficial, above muscularis mucosae, included muscularis mucosae), crush artefact (yes, no), and overall adequacy (inadequate, suboptimal, adequate). Twenty-four patients were enrolled (191 biopsies). The median length was approximately 5mm (range 1.1-8.2mm). Histologically inadequate specimens were present in 4% with the forceps without needle compared to 16% of those with needles (P=0.061) and there were significantly fewer specimens in three or more pieces than did the forceps with needles 2.1% vs. 12.6% (P<0.05). Current alligator style forceps provide a high proportion of acceptable specimens with only minor differences between brands. Forceps from one source were least preferred by endoscopy assistants and had the highest rates of inadequate biopsies and biopsies with crush artefact. Forceps without needles provide histologically acceptable samples slightly more frequently than those with needles.

  2. CT-guided transthoracic core needle biopsy for small pulmonary lesions: diagnostic performance and adequacy for molecular testing.

    PubMed

    Tian, Panwen; Wang, Ye; Li, Lei; Zhou, Yongzhao; Luo, Wenxin; Li, Weimin

    2017-02-01

    Computed tomography (CT)-guided transthoracic needle biopsy is a well-established, minimally invasive diagnostic tool for pulmonary lesions. Few large studies have been conducted on the diagnostic performance and adequacy for molecular testing of transthoracic core needle biopsy (TCNB) for small pulmonary lesions. This study included CT-guided TCNB with 18-gauge cutting needles in 560 consecutive patients with small (≤3 cm) pulmonary lesions from January 2012 to January 2015. There were 323 males and 237 females, aged 51.8±12.7 years. The size of the pulmonary lesions was 1.8±0.6 cm. The sensitivity, specificity, accuracy and complications of the biopsies were investigated. The risk factors of diagnostic failure were assessed using univariate and multivariate analyses. The sample's adequacy for molecular testing of non-small cell lung cancer (NSCLC) was analyzed. The overall sensitivity, specificity, and accuracy for diagnosis of malignancy were 92.0% (311/338), 98.6% (219/222), and 94.6% (530/560), respectively. The incidence of bleeding complications was 22.9% (128/560), and the incidence of pneumothorax was 10.4% (58/560). Logistic multivariate regression analysis showed that the independent risk factors for diagnostic failure were a lesion size ≤1 cm [odds ratio (OR), 3.95; P=0.007], lower lobe lesions (OR, 2.83; P=0.001), and pneumothorax (OR, 1.98; P=0.004). Genetic analysis was successfully performed on 95.45% (168/176) of specimens diagnosed as NSCLC. At least 96.8% of samples with two or more passes from a lesion were sufficient for molecular testing. The diagnostic yield of small pulmonary lesions by CT-guided TCNB is high, and the procedure is relatively safe. A lesion size ≤1 cm, lower lobe lesions, and pneumothorax are independent risk factors for biopsy diagnostic failure. TCNB specimens could provide adequate tissues for molecular testing.

  3. Contemporary prostate biopsy reporting: insights from a survey of clinicians' use of pathology data.

    PubMed

    Varma, Murali; Narahari, Krishna; Mason, Malcolm; Oxley, Jon D; Berney, Daniel M

    2018-05-02

    To determine how clinicians use data in contemporary prostate biopsy reports. A survey was circulated to members of the British Association of Urological Surgeons and the British Uro-oncology Group. Responses were received from 114 respondents (88 urologists, 26 oncologists). Ninety-seven (94%) use the number of positive cores from each side and 43 (42%) use the % number of positive cores. When determining the number and percentage of positive cores, 72 (71%) would not differentiate between targeted and non-targeted samples. If multiple Gleason Scores (GS) were included in a report, 77 (78%) would use the worst GS even if present in a core with very little tumour, 12% would use the global GS and 10% the GS in the core most involved by tumour. Fifty-five (55%) either never or rarely used perineural invasion for patient management. The number of positive cores is an important parameter for patient management but may be difficult to determine in the laboratory due to core fragmentation so the biopsy taker must indicate the number of biopsies obtained. Multiple biopsies taken from a single site are often interpreted by clinicians as separate cores when determining the number of positive cores so pathologists should also report the number of sites positive. Clinicians have a non-uniform approach to the interpretation of multiple GS in prostate biopsy reports so we recommend that pathologists also include a single 'bottom-line' GS for each case to direct the clinician's treatment decision. © Article author(s) (or their employer(s) unless otherwise stated in the text of the article) 2018. All rights reserved. No commercial use is permitted unless otherwise expressly granted.

  4. Use of Indocyanine Green for Sentinel Lymph Node Biopsy: Case Series and Methods Comparison.

    PubMed

    McGregor, Andrew; Pavri, Sabrina N; Tsay, Cynthia; Kim, Samuel; Narayan, Deepak

    2017-11-01

    Sentinel lymph node biopsy is indicated for patients with biopsy-proven thickness melanoma greater than 1.0 mm. Use of lymphoscintigraphy along with vital blue dyes is the gold standard for identifying sentinel lymph nodes intraoperatively. Indocyanine green (ICG) has recently been used as a method of identifying sentinel lymph nodes. We herein describe a case series of patients who have successfully undergone ICG-assisted sentinel lymph node biopsy for melanoma. We compare 2 imaging systems that are used for ICG-assisted sentinel lymph node biopsy. Fourteen patients underwent ICG-assisted sentinel lymph node biopsy for melanoma using the SPY Elite system (Novadaq, Mississigua, Canada) and the Hamamatsu PDE-Neo probe system (Mitaka USA, Park City, Utah). We analyzed costs for 2 systems that utilize ICG for sentinel lymph node biopsies. Intraoperative use of ICG for sentinel lymph node biopsies was successful in correctly identifying sentinel lymph nodes. There was no difference between the Hamamatsu PDE-Neo probe and SPY Elite systems in the ability to detect sentinel lymph nodes; however, the former was associated with a lower operating cost and ease of use compared with the latter. ICG-assisted sentinel lymph biopsy using the SPY Elite or the Hamamatsu PDE-Neo probe systems for melanoma are comparable in terms of sentinel node detection. The Neo probe system delivers pertinent clinical data with the advantages of lower cost and ease of operation.

  5. Documenting the location of systematic transrectal ultrasound-guided prostate biopsies: correlation with multi-parametric MRI.

    PubMed

    Turkbey, Baris; Xu, Sheng; Kruecker, Jochen; Locklin, Julia; Pang, Yuxi; Shah, Vijay; Bernardo, Marcelino; Baccala, Angelo; Rastinehad, Ardeshir; Benjamin, Compton; Merino, Maria J; Wood, Bradford J; Choyke, Peter L; Pinto, Peter A

    2011-03-29

    During transrectal ultrasound (TRUS)-guided prostate biopsies, the actual location of the biopsy site is rarely documented. Here, we demonstrate the capability of TRUS-magnetic resonance imaging (MRI) image fusion to document the biopsy site and correlate biopsy results with multi-parametric MRI findings. Fifty consecutive patients (median age 61 years) with a median prostate-specific antigen (PSA) level of 5.8 ng/ml underwent 12-core TRUS-guided biopsy of the prostate. Pre-procedural T2-weighted magnetic resonance images were fused to TRUS. A disposable needle guide with miniature tracking sensors was attached to the TRUS probe to enable fusion with MRI. Real-time TRUS images during biopsy and the corresponding tracking information were recorded. Each biopsy site was superimposed onto the MRI. Each biopsy site was classified as positive or negative for cancer based on the results of each MRI sequence. Sensitivity, specificity, and receiver operating curve (ROC) area under the curve (AUC) values were calculated for multi-parametric MRI. Gleason scores for each multi-parametric MRI pattern were also evaluated. Six hundred and 5 systemic biopsy cores were analyzed in 50 patients, of whom 20 patients had 56 positive cores. MRI identified 34 of 56 positive cores. Overall, sensitivity, specificity, and ROC area values for multi-parametric MRI were 0.607, 0.727, 0.667, respectively. TRUS-MRI fusion after biopsy can be used to document the location of each biopsy site, which can then be correlated with MRI findings. Based on correlation with tracked biopsies, T2-weighted MRI and apparent diffusion coefficient maps derived from diffusion-weighted MRI are the most sensitive sequences, whereas the addition of delayed contrast enhancement MRI and three-dimensional magnetic resonance spectroscopy demonstrated higher specificity consistent with results obtained using radical prostatectomy specimens.

  6. Robotic laparoscopic radical prostatectomy for biopsy Gleason 8 to 10: prediction of favorable pathologic outcome with preoperative parameters.

    PubMed

    Shikanov, Sergey A; Thong, Alan; Gofrit, Ofer N; Zagaja, Gregory P; Steinberg, Gary D; Shalhav, Arieh L; Zorn, Kevin C

    2008-07-01

    We sought to evaluate the pathologic results and postoperative outcomes for men undergoing robot-assisted laparoscopic radical prostatectomy (RLRP) for biopsy Gleason score (GS) 8 to 10 disease. Stratification of these patients according to preoperative variables was also performed in an attempt to predict organ-confined cancer. A prospective RLRP database identified all patients with preoperative biopsy GS 8 to 10. Variables, including prostate-specific antigen (PSA), percent positive biopsy cores (%PBC), maximal percentage of cancer in biopsy core (%MCB), clinical stage, pathologic stage, pathologic GS, surgical margins status, lymph node status, time to biochemical recurrence, and recurrence rate, were evaluated. Preoperative variables were treated as continuous and categorical using PSA, %PBC and %MCB cutoffs of 10 ng/mL, 50%, and 30%, respectively. Between February 2003 and September 2007, a total of 1225 RLRPs were performed at the University of Chicago Medical Center. Seventy-two (5.9%) patients had preoperative biopsy GS 8 to 10. Two patients received neoadjuvant hormonal therapy and were excluded. Among 70 patients evaluated, 33 (47%) had organconfined (pT(2)N0) disease. Forty (60.6%) patients had pathologic downgrading to GS biopsy GS 8 to 10 predicts a significant likelihood of finding non-organ-confined prostate cancer on the final pathology report. Preoperative PSA

  7. [Evaluation of postmenopausal uterine bleeding by endometrial biopsy in-office hysteroscopy vs endometrial biopsy with manual vacuum aspiration in the office. Preliminary report].

    PubMed

    Hernández, José Arias; Franco, María Eugenia Lozano; Mendizábal, David Pablo Bulnes; Broca, Yrma Bocanegra; Escoto, Adrián Fores

    2009-11-01

    To compare endometrial biopsy by hysteroscopy vs manual endouterine aspiration in office, in patients of Climateric Clinic from Hospital Regional de Alta Especialidad de la Mujer Tabasco, with postmenopausal uterine bleeding. There were included patients that come from October 30 2007 to December 20 2008 to Climateric Clinic, with abnormal uterine bleeding and without hormonal replacement therapy. There were taken biopsy by hysteroscopy and AMEU. The histopathology results were compared. A total of 25 women were evaluated. The average age was 53 years (+/- 5.6). The delivery average was 3 births (+/- 1). We found polyps in 9 (37%) patients, endometrial atrophy in 3 (13%), cystic hyperplasia in 2 (8%), proliferative endometrium in 4 (17%), submucous myomas in 5 (21%) and neoplasia in 1 (4%). The correlation between endometrial biopsy by hysteroscopy and AMEU was 100% for endometrial atrophy, cystic hyperplasia, proliferativo endometrium and neoplasia. There was not correlation between manual endouterine aspiration and endometrial biopsy by hysteroscopy for polyps and submucous myomas. We didn't have complications during the procedures. Hysteroscopic endometrial biopsy seems to have the same histopathology results than AMEU for endometrial atrophy, cystic hyperplasia, proliferative endometrium and neoplasia, not for miomas and polyps. Hysteroscopy can give us the possibility to see miomas and polyps and treat surgical pathology at the same moment almost in all cases.

  8. Can Vacuum Assisted Venous Drainage be Achieved using a Roller Pump in an Emergency? A Pilot Study using Neonatal Circuitry

    PubMed Central

    Hill, S. L.; Holt, D. W.

    2007-01-01

    Abstract: There has been much advancement in perfusion technology over its 50 years of progression. One of these techniques is vacuum-assisted venous drainage (VAVD). Many perfusionists augment venous drainage using VAVD, typically from a wall vacuum source. This study explores alternates to providing VAVD if the wall vacuum fails. In two porcine laboratories, ∼36 in. of 3/16-in. tubing was connected to a sucker return port and placed into the roller head next to the arterial pump. The vacuum was monitored with a DLP pressure monitoring system (Medtronic). This system was connected to small-bore tubing and attached to a stopcock on top of the reservoir. The vacuum was regulated using another stopcock connected to a non-filtered luer lock port on top of the reservoir or by a segment of 3 × 0.25-in.-diameter tubing attached to the vent port with a c-clamp. Vacuum drainage was achieved, ranging from −18 mmHg to −71 mmHg by manipulating the stopcock or c-clamp. Changes in venous drainage were seen by volume fluctuations in the venous reservoir. The vacuum was adjusted to account for dramatic changes. Augmented venous drainage using a roller pump can be achieved successfully during cardiopulmonary bypass (CPB). This method of active drainage can be used in lieu of wall suction or during times of emergency if wall suction fails. PMID:18293812

  9. Robotically assisted small animal MRI-guided mouse biopsy

    NASA Astrophysics Data System (ADS)

    Wilson, Emmanuel; Chiodo, Chris; Wong, Kenneth H.; Fricke, Stanley; Jung, Mira; Cleary, Kevin

    2010-02-01

    Small mammals, namely mice and rats, play an important role in biomedical research. Imaging, in conjunction with accurate therapeutic agent delivery, has tremendous value in small animal research since it enables serial, non-destructive testing of animals and facilitates the study of biomarkers of disease progression. The small size of organs in mice lends some difficulty to accurate biopsies and therapeutic agent delivery. Image guidance with the use of robotic devices should enable more accurate and repeatable targeting for biopsies and delivery of therapeutic agents, as well as the ability to acquire tissue from a pre-specified location based on image anatomy. This paper presents our work in integrating a robotic needle guide device, specialized stereotaxic mouse holder, and magnetic resonance imaging, with a long-term goal of performing accurate and repeatable targeting in anesthetized mice studies.

  10. Pilot study of a novel vacuum-assisted method for decellularization of tracheae for clinical tissue engineering applications.

    PubMed

    Lange, P; Greco, K; Partington, L; Carvalho, C; Oliani, S; Birchall, M A; Sibbons, P D; Lowdell, M W; Ansari, T

    2017-03-01

    Tissue engineered tracheae have been successfully implanted to treat a small number of patients on compassionate grounds. The treatment has not become mainstream due to the time taken to produce the scaffold and the resultant financial costs. We have developed a method for decellularization (DC) based on vacuum technology, which when combined with an enzyme/detergent protocol significantly reduces the time required to create clinically suitable scaffolds. We have applied this technology to prepare porcine tracheal scaffolds and compared the results to scaffolds produced under normal atmospheric pressures. The principal outcome measures were the reduction in time (9 days to prepare the scaffold) followed by a reduction in residual DNA levels (DC no-vac: 137.8±48.82 ng/mg vs. DC vac 36.83±18.45 ng/mg, p<0.05.). Our approach did not impact on the collagen or glycosaminoglycan content or on the biomechanical properties of the scaffolds. We applied the vacuum technology to human tracheae, which, when implanted in vivo showed no significant adverse immunological response. The addition of a vacuum to a conventional decellularization protocol significantly reduces production time, whilst providing a suitable scaffold. This increases clinical utility and lowers production costs. To our knowledge this is the first time that vacuum assisted decellularization has been explored. Copyright © 2015 John Wiley & Sons, Ltd. Copyright © 2015 John Wiley & Sons, Ltd.

  11. Electrical property sensing biopsy needle for prostate cancer detection.

    PubMed

    Mishra, V; Schned, A R; Hartov, A; Heaney, J A; Seigne, J; Halter, R J

    2013-11-01

    Significant electrical property differences have been demonstrated to exist between malignant and benign prostate tissues. We evaluated how well a custom designed clinically deployable electrical property sensing biopsy needle is able to discriminate between these tissue types in an ex vivo prostate model. An electrical impedance spectroscopy (EIS) sensing biopsy (Bx) needle was developed to record resistive (ρR) and reactive (ρX) components of electrical impedance from 100 Hz to 1 MHz. Standard twelve-core biopsy protocols were followed, in which the EIS-Bx device was used to gauge electrical properties prior to extracting tissue cores through biopsy needle firing from 36 ex vivo human prostates. Histopathological assessment of the cores was statistically compared to the impedance spectrum gauged from each core. The magnitudes of the mean resistive and reactive components were significantly higher in cancer tissues (P < 0.05). ROC curves showed that ρR at 63.09 kHz was optimal for discriminating cancer from benign tissues; this parameter had 75.4% specificity, 76.1% sensitivity, and ROC AUC of 0.779. Similarly, 251.1 kHz was optimal when using ρX to discriminate cancer from benign tissues; this parameter had a 77.9% specificity, 71.4% sensitivity, and ROC AUC of 0.79. Significant electrical property differences noted between benign and malignant prostate tissues suggest the potential efficacy an EIS-Bx device would provide for cancer detection in a clinical setting. By sensing a greater fraction of the prostate's volume in real-time, the EIS-Bx device has the potential to improve the accuracy of cancer grading and volume estimation made with current biopsy procedures. © 2013 Wiley Periodicals, Inc.

  12. Determinants of complications after multiple transrectal core biopsies of the prostate.

    PubMed

    Norberg, M; Holmberg, L; Häggman, M; Magnusson, A

    1996-01-01

    Transrectal ultrasound-guided biopsies of the prostate were performed on 347 consecutive men. All patients were given prophylactic antibiotics. The first 199 patients received 400 mg norfloxacin immediately after the biopsies were performed and 400 mg the same evening. The second group of 148 patients received 400 mg of norfloxacin 1 h before the examination followed by five doses administered twice daily. A total of 15 major complications were noted. In the first group the complication rate was 6.5% and in the second group 1.4%. The different regimes of prophylactic antibiotic treatment were the only parameters shown to have a statistically significant impact on the complication rate. The number of complications decreased, but were not eliminated, when prophylactic treatment with norfloxacin was given before the biopsies were taken and continued for a total of 3 days.

  13. Pleuroparenchymal fibroelastosis: role of high-resolution computed tomography (HRCT) and CT-guided transthoracic core lung biopsy.

    PubMed

    Esteves, Cátia; Costa, Francisco R; Redondo, Margarida T; Moura, Conceição S; Guimarães, Susana; Morais, António; Pereira, José M

    2016-02-01

    Pleuroparenchymal fibroelastosis (PPFE) is a rare idiopathic interstitial pneumonia (IIP) with variable clinical and radiological features. Diagnosis is based on histology obtained by surgical lung biopsy, which is associated with significant mortality and morbidity. This study aims to briefly review PPFE and discuss the role of CT-guided transthoracic core lung biopsy (TTB) in its diagnosis. Four cases of PPFE diagnosed at our institution with TTB are reported and discussed. Clinical, radiological and histological features are in agreement with the previous literature cases. TTB provided the diagnosis in all cases. Iatrogenic pneumothorax was the main complication in all patients. Placement of a chest tube was needed in three patients. An overlap between PPFE and other interstitial lung diseases (ILD) was documented. PPFE is an underdiagnosed IIP, so radiologist awareness of it needs to be widespread in patients with fibrosis with apical-caudal distribution. Coexistence of different lung diseases strengthens the idea of a predisposing factor. TTB proved to be a good diagnostic tool and can be considered the first choice for invasive assessment of these patients. PFFE has a variable course with no established therapeutic options; therefore a multidisciplinary team is crucial in the approach to patients with ILD. • PPFE should be considered in the differential diagnosis of fibrosis with apical-caudal distribution. • CT-guided TTB can be considered the first choice for invasive assessment of PPFE. • Site of biopsy has to be chosen carefully in order not to miss PPFE. • Coexistence of different lung diseases strengthens the idea of a predisposing factor. • A multidisciplinary team is crucial in the approach to patients with ILD.

  14. Development of High Performance Composite Foam Insulation with Vacuum Insulation Cores

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Biswas, Kaushik; Desjarlais, Andre Omer; SmithPhD, Douglas

    Development of a high performance thermal insulation (thermal resistance or R-value per inch of R-12 hr-ft2- F/Btu-in or greater), with twice the thermal resistance of state-of-the-art commercial insulation materials ( R6/inch for foam insulation), promises a transformational impact in the area of building insulation. In 2010, in the US, the building envelope-related primary energy consumption was 15.6 quads, of which 5.75 quads were due to opaque wall and roof sections; the total US consumption (building, industrial and transportation) was 98 quads. In other words, the wall and roof contribution was almost 6% of the entire US primary energy consumption. Buildingmore » energy modeling analyses have shown that adding insulation to increase the R-value of the external walls of residential buildings by R10-20 (hr-ft2- F/Btu) can yield savings of 38-50% in wall-generated heating and cooling loads. Adding R20 will require substantial thicknesses of current commercial insulation materials, often requiring significant (and sometimes cost-prohibitive) alterations to existing buildings. This article describes the development of a next-generation composite insulation with a target thermal resistance of R25 for a 2 inch thick board (R12/inch or higher). The composite insulation will contain vacuum insulation cores, which are nominally R35-40/inch, encapsulated in polyisocyanurate foam. A recently-developed variant of vacuum insulation, called modified atmosphere insulation (MAI), was used in this research. Some background information on the thermal performance and distinguishing features of MAI has been provided. Technical details of the composite insulation development and manufacturing as well as laboratory evaluation of prototype insulation boards are presented.« less

  15. Abdominal Subcutaneous Mass After Laser-Assisted Lipolysis and Immediate Multiple Treatments with a Dual-Wavelength Laser, Vacuum and Massage Device.

    PubMed

    Gentileschi, Stefano; Servillo, Maria; D'Ettorre, Marco; Salgarello, Marzia

    2016-04-01

    Body contouring by means of minimally invasive procedures is a growing trend. Current approaches to body contouring often involve a combination of surgical techniques (eg, laser-assisted liposuction) and a series of noninvasive device-based treatments aimed at accelerating recovery and improving aesthetic outcomes. In this case study, we describe a 38-year-old woman who presented with an abdominal-wall mass that resembled a tumor when assessed with magnetic resonance imaging. Twenty-six months before presenting to our office, the patient had undergone laser lipolysis and a series of treatments with a device that delivered dual-wavelength laser energy and vacuum-assisted massage. To address the patient's concerns, we removed the mass and performed abdominal dermolipectomy. No postoperative complications occurred, and the patient was highly satisfied with the aesthetic outcome. The results of histologic studies indicated that the mass was pseudocystic and fluid-filled, surrounded by a fibrous capsule, and characterized as a foreign-body granuloma. Further analysis is warranted regarding the safety of laser lipolysis without aspiration combined with a device delivering dual-wavelength laser energy and vacuum-assisted massage. 5 Risk. © 2015 The American Society for Aesthetic Plastic Surgery, Inc. Reprints and permission: journals.permissions@oup.com.

  16. Ultrasound-guided core needle biopsy of cervical lymph nodes in the diagnosis of toxoplasmosis.

    PubMed

    Cho, Woojin; Kim, Min Kyung; Sim, Jung Suk

    2017-05-01

    Our study investigates whether the histopathological features of toxoplasmic lymphadenitis (TL), specifically noncaseating microgranuloma and follicular hyperplasia, can be obtained by sonographic-guided core needle biopsy (CNB) of cervical lymph nodes. Thirty-two patients seen from June 2014 to March 2015 were positive for toxoplasma immunoglobulin M antibody. Among those patients, 21 underwent CNB of a cervical lymph node and were enrolled in this study. The pathologic findings were reviewed. Twenty-nine lymph nodes in 21 patients were sampled. Eighteen of the 21 (86%) patients had a microgranuloma without caseating necrosis or giant cells, and all 21 (100%) patients had follicular hyperplasia. The histologic findings of TL were detected by sonographic-guided CNB, which can be used as part of the first line of investigation in patients with unexplained cervical adenopathy. © 2016 Wiley Periodicals, Inc. J Clin Ultrasound 45:192-196, 2017. © 2016 Wiley Periodicals, Inc.

  17. A CT-guided fat transversing coaxial biopsy technique for pancreatic lesion biopsy that avoids major organs and vessels

    PubMed Central

    Lin, Chia-Ying; Ou, Ming-Ching; Liu, Yi-Sheng; Chuang, Ming-Tsung; Shan, Yan-Shen; Tsai, Hong-Ming; Wang, Chien-Kuo; Tsai, Yi-Shan

    2017-01-01

    Background/Aims: The purpose of this study is to report our results using a computed tomography (CT)-guided fat transversing coaxial biopsy technique for pancreatic lesion biopsy that avoids major organs and vessels. We retrospectively reviewed the records of patients referred to our department for pancreatic mass biopsy. Patients and Methods: The records of patients (from June 2008 to August 2014) in whom biopsy was performed under CT guidance with a coaxial needle using a fat transversing technique were reviewed. Patient demographic data and biopsy outcomes were collected. We aimed to compare differences between lesion size and biopsy outcome, the independent two-samples t-test was used. Results: A total of 122 patients who underwent 17-G coaxial needle biopsy were included. The mean pancreatic lesion size was 3.2 cm, and in 30 patients it was more than 4 cm. The majority of lesions were located in the head of the pancreas (44.3%). No transorgan biopsies were performed. In most patients, the biopsy was performed via a fat traversing detour route (93.4%), and a successful diagnosis was made based on the biopsy outcome in 96.7% patients. Complications occurred in five patients (4.1%); three of the patients developed a fever, and two developed pancreatitis. All patients recovered with symptomatic treatment. Conclusion: CT-guided coaxial core biopsy of pancreatic lesions using a fat detour route appears to be a safe and effective method for obtaining pancreatic lesion biopsies with a high success rate and low complication rate. PMID:29205187

  18. Early Conversion of External Fixation to Interlocked Nailing in Open Fractures of Both Bone Leg Assisted with Vacuum Closure (VAC) - Final Outcome

    PubMed Central

    Raj, Manish; Kumar, Sunil; Singh, Pulkesh; Kumar, Dinesh; Singh, Jasveer; Deep, Akash

    2016-01-01

    Introduction Management of compound grade III fractures of both bone leg includes external stabilization for long period, followed by various soft tissue coverage procedures. Primary interlocking of tibia had been also done with variable results. External fixation for long time without any bone loss often leads to infected nonunion, loss of reduction, pin tract infection and failure of fixation, primary interlocking in compound grade III fractures had shown high medullary infection rate. We managed all cases of compound grade III A/B fractures with primary external fixation, simultaneous wound management using vacuum assisted closure (VAC) followed by early conversion to interlocking within 2 weeks of fixator application. Aim To determine the effectiveness of vacuum assisted closure (VAC) for the early conversion of external fixator to definitive interlocking in open fractures of the both bone leg. Materials and Methods In current study we selected 84 cases of compound grade IIIA/B diaphyseal fractures of both bone leg during period of May 2010 to September 2013. We managed these cases by immediate debridement and application of external fixation followed by repeated debridement, application of vacuum assisted closure (VAC) and conversion to interlocking within two weeks. Results Out of 84 cases union was achieved in 80(95%) of cases with definitive tibial interlocking. Excellent to good result were obtained in 77(91.8%) of cases and fair to poor result seen in rest of 7(8.2%) of cases according to modified Ketenjian’s criteria. 5 out of these 7 poor result group cases were from Compound Grade III B group to start with. Deep infection rate in our series were 7% i.e. total 6 cases and 4 out of these were from compound Grade III B group to start with. Conclusion Vacuum assisted closure (VAC) give a good help for rapid closure of the wound and help in early conversion to definitive intramedullary nailing. Reamed nail could well be used in compound grade IIIA

  19. A single microfocus (5% or less) of Gleason 6 prostate cancer at biopsy--can we predict adverse pathological outcomes?

    PubMed

    Thong, Alan E; Shikanov, Sergey; Katz, Mark H; Gofrit, Ofer N; Eggener, Scott; Zagaja, Gregory P; Shalhav, Arieh L; Zorn, Kevin C

    2008-12-01

    Patients with Gleason score 6 microfocal prostate cancer, defined as 5% or less in 1 biopsy core, are often considered to have favorable disease. Few studies have addressed clinical parameters that predict pathological upgrading or up staging at radical prostatectomy. From a prospective database of 1,271 consecutive robot assisted laparoscopic prostatectomies performed from 2003 to 2008 patients with Gleason score 6 microfocal prostate cancer were identified. Adverse pathological outcome was defined as any upgrading and/or up staging on prostatectomy pathological findings. Multivariate logistic regression was used to evaluate the ability of patient age, clinical stage, the total number of biopsy cores, preoperative prostate specific antigen, prostate volume and pathological prostate specific antigen density to predict adverse pathological outcomes. A total of 192 patients with a median age of 59 years (range 42 to 73) were identified with Gleason score 6 prostate cancer involving 5% or less of 1 biopsy core, including 177 (92%) with clinical T1c disease. Mean +/- SD preoperative prostate specific antigen was 6.0 +/- 3.9 ng/ml (range 0.8 to 35). Overall 42 patients (22%) had adverse pathological outcomes, including upgrading in 35 (18%) and up staging in 16 (8%). Multivariate logistic regression revealed that age more than 65 years and pathological prostate specific antigen density greater than 0.20 ng/ml/gm were predictive of an increased risk of adverse pathological results (p = 0.0081 and 0.0169, respectively). While a microfocus of Gleason score 6 prostate cancer on biopsy is commonly considered low risk disease, there was a greater than 1/5 risk of pathological upgrading and/or up staging. Patients with Gleason score 6 microfocal prostate cancer should be counseled that they may harbor more aggressive disease, especially when pretreatment clinical risk factors are present, such as advanced age or high clinical prostate specific antigen density.

  20. Physician-Assisted Suicide and Euthanasia in the ICU: A Dialogue on Core Ethical Issues.

    PubMed

    Goligher, Ewan C; Ely, E Wesley; Sulmasy, Daniel P; Bakker, Jan; Raphael, John; Volandes, Angelo E; Patel, Bhavesh M; Payne, Kate; Hosie, Annmarie; Churchill, Larry; White, Douglas B; Downar, James

    2017-02-01

    Many patients are admitted to the ICU at or near the end of their lives. Consequently, the increasingly common debate regarding physician-assisted suicide and euthanasia holds implications for the practice of critical care medicine. The objective of this article is to explore core ethical issues related to physician-assisted suicide and euthanasia from the perspective of healthcare professionals and ethicists on both sides of the debate. We identified four issues highlighting the key areas of ethical tension central to evaluating physician-assisted suicide and euthanasia in medical practice: 1) the benefit or harm of death itself, 2) the relationship between physician-assisted suicide and euthanasia and withholding or withdrawing life support, 3) the morality of a physician deliberately causing death, and 4) the management of conscientious objection related to physician-assisted suicide and euthanasia in the critical care setting. We present areas of common ground and important unresolved differences. We reached differing positions on the first three core ethical questions and achieved unanimity on how critical care clinicians should manage conscientious objections related to physician-assisted suicide and euthanasia. The alternative positions presented in this article may serve to promote open and informed dialogue within the critical care community.

  1. Multispectral Fluorescence Imaging During Robot-assisted Laparoscopic Sentinel Node Biopsy: A First Step Towards a Fluorescence-based Anatomic Roadmap.

    PubMed

    van den Berg, Nynke S; Buckle, Tessa; KleinJan, Gijs H; van der Poel, Henk G; van Leeuwen, Fijs W B

    2017-07-01

    During (robot-assisted) sentinel node (SN) biopsy procedures, intraoperative fluorescence imaging can be used to enhance radioguided SN excision. For this combined pre- and intraoperative SN identification was realized using the hybrid SN tracer, indocyanine green- 99m Tc-nanocolloid. Combining this dedicated SN tracer with a lymphangiographic tracer such as fluorescein may further enhance the accuracy of SN biopsy. Clinical evaluation of a multispectral fluorescence guided surgery approach using the dedicated SN tracer ICG- 99m Tc-nanocolloid, the lymphangiographic tracer fluorescein, and a commercially available fluorescence laparoscope. Pilot study in ten patients with prostate cancer. Following ICG- 99m Tc-nanocolloid administration and preoperative lymphoscintigraphy and single-photon emission computed tomograpy imaging, the number and location of SNs were determined. Fluorescein was injected intraprostatically immediately after the patient was anesthetized. A multispectral fluorescence laparoscope was used intraoperatively to identify both fluorescent signatures. Multispectral fluorescence imaging during robot-assisted radical prostatectomy with extended pelvic lymph node dissection and SN biopsy. (1) Number and location of preoperatively identified SNs. (2) Number and location of SNs intraoperatively identified via ICG- 99m Tc-nanocolloid imaging. (3) Rate of intraoperative lymphatic duct identification via fluorescein imaging. (4) Tumor status of excised (sentinel) lymph node(s). (5) Postoperative complications and follow-up. Near-infrared fluorescence imaging of ICG- 99m Tc-nanocolloid visualized 85.3% of the SNs. In 8/10 patients, fluorescein imaging allowed bright and accurate identification of lymphatic ducts, although higher background staining and tracer washout were observed. The main limitation is the small patient population. Our findings indicate that a lymphangiographic tracer can provide additional information during SN biopsy based on ICG- 99m

  2. [The Diagnostic Value of Pre-Biopsy Magnetic Resonance Imaging (MRI) for Detecting Prostate Cancer].

    PubMed

    Mori, Kohei; Miyoshi, Yasuhide; Yoneyama, Shuko; Ishida, Hiroaki; Hattori, Yusuke; Teranishi, Jun-ichi; Kondo, Keiichi; Noguchi, Kazumi

    2016-01-01

    We examined the value of pre-biopsy magnetic resonance imaging (MRI) for detecting prostate cancer. We analyzed 267 men with prostate-specific antigen (PSA) levels of 3-10 ng/ml who underwent systematic prostate needle biopsy. From April 2009 to March 2011, a total of 98 male patients underwent 16-core prostatic biopsies without pre-biopsy magnetic resonance imaging (MRI) (nonenforcement group). From April 2011 to March 2013, 169 men underwent pre-biopsy MRI [T2-weighted imaging (T2WI) and diffusion-weighted imaging (DWI)] (enforcement group). When MRI findings indicated cancer in the latter group, in addition to the systematic 16-core biopsy one or two targeted biopsies were performed. Patients without suspicious MRI findings underwent only systematic 16-core biopsy. Cancer detection rates in the nonenforcement and enforcement groups were 42.9% (48/92) and 46. 2% (78/169), respectively. The difference did not reach significance (p=0.612). Although the cancer detection rates were 39.4% (41/104) in the MRI-negative group and 56. 9% (37/65) in the MRI-positive group (p=0.039), the sensitivity and specificity for cancer detection by MRI were relatively low: 47.4% and 69.2%, respectively. By receiver-operating curve analysis, the area under the curve for cancer detection by MRI was only 0.583. There were two study limitations. First, the patient sample size was small. Second, it is unclear whether an adequate sample of the suspicious lesion was obtained by biopsy. We thus demonstrated that it might be improper to base a diagnosis solely on pre-biopsy MRI (T2WI and DWI) findings in men with serum PSA levels of 3-10 ng/ml.

  3. Technical specification for vacuum systems

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Khaw, J.

    The vacuum systems at the Stanford Linear Accelerator Center (SLAC) are primarily of all-metal construction and operate at pressures from 10/sup -5/ to 10/sup -11/ Torr. The primary gas loads during operation result from thermal desorption and beam-induced desorption from the vacuum chamber walls. These desorption rates can be extremely high in the case of hydrocarbons and other contaminants. These specifications place a major emphasis on eliminating contamination sources. The specifications and procedures have been written to insure the cleanliness and vacuum integrity of all SLAC vacuum systems, and to assist personnel involved with SLAC vacuum systems in choosing andmore » designing components that are compatible with existing systems and meet the quality and reliability of SLAC vacuum standards. The specification includes requirements on design, procurement, fabrication, chemical cleaning, clean room practices, welding and brazing, helium leak testing, residual gas analyzer testing, bakeout, venting, and pumpdown. Also appended are specifications regarding acceptable vendors, isopropyl alcohol, bakeable valve cleaning procedure, mechanical engineering safety inspection, notes on synchrotron radiation, and specifications of numerous individual components. (LEW)« less

  4. Indocyanine green SPY elite-assisted sentinel lymph node biopsy in cutaneous melanoma.

    PubMed

    Korn, Jason M; Tellez-Diaz, Alejandra; Bartz-Kurycki, Marisa; Gastman, Brian

    2014-04-01

    Sentinel lymph node biopsy is the standard of care for intermediate-depth and high-risk thin melanomas. Recently, indocyanine green and near-infrared imaging have been used to aid in sentinel node biopsy. The present study aimed to determine the feasibility of sentinel lymph node biopsy with indocyanine green SPY Elite navigation and to critically evaluate the technique compared with the standard modalities. A retrospective review of 90 consecutive cutaneous melanoma patients who underwent sentinel lymph node biopsy was performed. Two cohorts were formed: group A, which had sentinel lymph node biopsy performed with blue dye and radioisotope; and group B, which had sentinel lymph node biopsy performed with radioisotope and indocyanine green SPY Elite navigation. The cohorts were compared to assess for differences in localization rates, sensitivity and specificity of sentinel node identification, and length of surgery. The sentinel lymph node localization rate was 79.4 percent using the blue dye method, 98.0 percent using the indocyanine green fluorescence method, and 97.8 percent using the radioisotope/handheld gamma probe method. Indocyanine green fluorescence detected more sentinel lymph nodes than the vital dye method alone (p = 0.020). A trend toward a reduction in length of surgery was noted in the SPY Elite cohort. Sentinel lymph node mapping and localization in cutaneous melanoma with the indocyanine green SPY Elite navigation system is technically feasible and may offer several advantages over current modalities, including higher sensitivity and specificity, decreased number of lymph nodes sampled, decreased operative time, and potentially lower false-negative rates. Diagnostic, II.

  5. Magnetic Resonance and Ultrasound Image Fusion Supported Transperineal Prostate Biopsy Using the Ginsburg Protocol: Technique, Learning Points, and Biopsy Results.

    PubMed

    Hansen, Nienke; Patruno, Giulio; Wadhwa, Karan; Gaziev, Gabriele; Miano, Roberto; Barrett, Tristan; Gnanapragasam, Vincent; Doble, Andrew; Warren, Anne; Bratt, Ola; Kastner, Christof

    2016-08-01

    Prostate biopsy supported by transperineal image fusion has recently been developed as a new method to the improve accuracy of prostate cancer detection. To describe the Ginsburg protocol for transperineal prostate biopsy supported by multiparametric magnetic resonance imaging (mpMRI) and transrectal ultrasound (TRUS) image fusion, provide learning points for its application, and report biopsy results. The article is supplemented by a Surgery in Motion video. This single-centre retrospective outcome study included 534 patients from March 2012 to October 2015. A total of 107 had no previous prostate biopsy, 295 had benign TRUS-guided biopsies, and 159 were on active surveillance for low-risk cancer. A Likert scale reported mpMRI for suspicion of cancer from 1 (no suspicion) to 5 (cancer highly likely). Transperineal biopsies were obtained under general anaesthesia using BiopSee fusion software (Medcom, Darmstadt, Germany). All patients had systematic biopsies, two cores from each of 12 anatomic sectors. Likert 3-5 lesions were targeted with a further two cores per lesion. Any cancer and Gleason score 7-10 cancer on biopsy were noted. Descriptive statistics and positive predictive values (PPVs) and negative predictive values (NPVs) were calculated. The detection rate of Gleason score 7-10 cancer was similar across clinical groups. Likert scale 3-5 MRI lesions were reported in 378 (71%) of the patients. Cancer was detected in 249 (66%) and Gleason score 7-10 cancer was noted in 157 (42%) of these patients. PPV for detecting 7-10 cancer was 0.15 for Likert score 3, 0.43 for score 4, and 0.63 for score 5. NPV of Likert 1-2 findings was 0.87 for Gleason score 7-10 and 0.97 for Gleason score ≥4+3=7 cancer. Limitations include lack of data on complications. Transperineal prostate biopsy supported by MRI/TRUS image fusion using the Ginsburg protocol yielded high detection rates of Gleason score 7-10 cancer. Because the NPV for excluding Gleason score 7-10 cancer was very

  6. Visually directed vs. software-based targeted biopsy compared to transperineal template mapping biopsy in the detection of clinically significant prostate cancer.

    PubMed

    Valerio, Massimo; McCartan, Neil; Freeman, Alex; Punwani, Shonit; Emberton, Mark; Ahmed, Hashim U

    2015-10-01

    Targeted biopsy based on cognitive or software magnetic resonance imaging (MRI) to transrectal ultrasound registration seems to increase the detection rate of clinically significant prostate cancer as compared with standard biopsy. However, these strategies have not been directly compared against an accurate test yet. The aim of this study was to obtain pilot data on the diagnostic ability of visually directed targeted biopsy vs. software-based targeted biopsy, considering transperineal template mapping (TPM) biopsy as the reference test. Prospective paired cohort study included 50 consecutive men undergoing TPM with one or more visible targets detected on preoperative multiparametric MRI. Targets were contoured on the Biojet software. Patients initially underwent software-based targeted biopsies, then visually directed targeted biopsies, and finally systematic TPM. The detection rate of clinically significant disease (Gleason score ≥3+4 and/or maximum cancer core length ≥4mm) of one strategy against another was compared by 3×3 contingency tables. Secondary analyses were performed using a less stringent threshold of significance (Gleason score ≥4+3 and/or maximum cancer core length ≥6mm). Median age was 68 (interquartile range: 63-73); median prostate-specific antigen level was 7.9ng/mL (6.4-10.2). A total of 79 targets were detected with a mean of 1.6 targets per patient. Of these, 27 (34%), 28 (35%), and 24 (31%) were scored 3, 4, and 5, respectively. At a patient level, the detection rate was 32 (64%), 34 (68%), and 38 (76%) for visually directed targeted, software-based biopsy, and TPM, respectively. Combining the 2 targeted strategies would have led to detection rate of 39 (78%). At a patient level and at a target level, software-based targeted biopsy found more clinically significant diseases than did visually directed targeted biopsy, although this was not statistically significant (22% vs. 14%, P = 0.48; 51.9% vs. 44.3%, P = 0.24). Secondary

  7. The best prostate biopsy scheme is dictated by the gland volume: a monocentric study.

    PubMed

    Dell'Atti, L

    2015-08-01

    Accuracy of biopsy scheme depends on different parameters. Prostate-specific antigen (PSA) level and digital rectal examination (DRE) influenced the detection rate and suggested the biopsy scheme to approach each patient. Another parameter is the prostate volume. Sampling accuracy tends to decrease progressively with an increasing prostate volume. We prospectively observed detection cancer rate in suspicious prostate cancer (PCa) and improved by applying a protocol biopsy according to prostate volume (PV). Clinical data and pathological features of these 1356 patients were analysed and included in this study. This protocol is a combined scheme that includes transrectal (TR) 12-core PBx (TR12PBx) for PV ≤ 30 cc, TR 14-core PBx (TR14PBx) for PV > 30 cc but < 60 cc, TR 18-core PBx (TR18PBx) for PV ≥ 60 cc. Out of a total of 1356 patients, in 111 (8.2%) PCa was identified through TR12PBx scheme, in 198 (14.6%) through TR14PBx scheme and in 253 (18.6%) through TR18PBx scheme. The PCa detection rate was increased by 44% by adding two TZ cores (TR14PBx scheme). The TR18PBx scheme increased this rate by 21.7% vs. TR14PBx scheme. The diagnostic yield offered by TR18PBx was statistically significant compared to the detection rate offered by the TR14PBx scheme (p < 0.003). The biopsy Gleason score and the percentage of core involvement were comparable between PCa detected by the TR14PBx scheme diagnostic yield and those detected by the TR18PBx scheme (p = 0.362). The only PV parameter, in our opinion, can be significant in choosing the best biopsy scheme to approach in a first setting of biopsies increasing PCa detection rate.

  8. An innovative intermittent-vacuum assisted thermophilic anaerobic digestion process for effective animal manure utilization and treatment.

    PubMed

    Zhang, Renchuan; Anderson, Erik; Addy, Min; Deng, Xiangyuan; Kabir, Fayal; Lu, Qian; Ma, Yiwei; Cheng, Yanling; Liu, Yuhuan; Chen, Paul; Ruan, Roger

    2017-11-01

    Intermittent-vacuum stripping (IVS) was developed as a pretreatment for thermophilic anaerobic digestion (TAD) to improve methanogenesis and hydrolysis activity through preventing free ammonia and hydrogen sulfide (H 2 S) inhibition from liquid swine manure (LSM). Over 98% of ammonia and 38% organic nitrogen were removed in 60min from 55°C to 85°C with vacuum pressure (from 100.63±3.79mmHg to 360.91±7.39mmHg) at initial pH 10.0 by IVS. Thermophilic methanogenesis and hydrolysis activity of pretreated LSM increased 52.25% (from 11.56±1.75% to 17.60±0.49%) in 25days and 40% (from 10days to 6days) in bio-methane potential assay. Over 80% H 2 S and total nitrogen were removed by IVS assistance, while around 70% nitrogen was recycled as ammonium sulfate. Therefore, IVS-TAD combination could be an effective strategy to improve TAD efficiency, whose elution is more easily utilized in algae cultivation and/or hydroponic system. Copyright © 2017 Elsevier Ltd. All rights reserved.

  9. Vacuum assisted birth and risk for cerebral complications in term newborn infants: a population-based cohort study.

    PubMed

    Ekéus, Cecilia; Högberg, Ulf; Norman, Mikael

    2014-01-20

    Few studies have focused on cerebral complications among newborn infants delivered by vacuum extraction (VE). The aim of this study was to determine the risk for intracranial haemorrhage and/or cerebral dysfunction in newborn infants delivered by VE and to compare this risk with that after cesarean section in labour (CS) and spontaneous vaginal delivery, respectively. Data was obtained from Swedish national registers. In a population-based cohort from 1999 to 2010 including all singleton newborn infants delivered at term after onset of labour by VE (n = 87,150), CS (75,216) or spontaneous vaginal delivery (n = 851,347), we compared the odds for neonatal intracranial haemorrhage, traumatic or non-traumatic, convulsions or encephalopathy. Logistic regressions were used to calculate adjusted (for major risk factors and indication) odds ratios (AOR), using spontaneous vaginal delivery as reference group. The rates of traumatic and non-traumatic intracranial hemorrhages were 0.8/10,000 and 3.8/1,000. VE deliveries provided 58% and 31.5% of the traumatic and non-traumatic cases, giving a ten-fold risk [AOR 10.05 (4.67-21.65)] and double risk [AOR 2.23 (1.57-3.16)], respectively. High birth weight and short mother were associated with the highest risks. Infants delivered by CS had no increased risk for intracranial hemorrhages. The risks for convulsions or encephalopathy were similar among infants delivered by VE and CS, exceeding the OR after non-assisted spontaneous vaginal delivery by two-to-three times. Vacuum assisted delivery is associated with increased risk for neonatal intracranial hemorrhages. Although causality could not be established in this observational study, it is important to be aware of the increased risk of intracranial hemorrhages in VE deliveries, particularly in short women and large infants. The results warrant further studies in decision making and conduct of assisted vaginal delivery.

  10. Psoriasis skin biopsy image segmentation using Deep Convolutional Neural Network.

    PubMed

    Pal, Anabik; Garain, Utpal; Chandra, Aditi; Chatterjee, Raghunath; Senapati, Swapan

    2018-06-01

    Development of machine assisted tools for automatic analysis of psoriasis skin biopsy image plays an important role in clinical assistance. Development of automatic approach for accurate segmentation of psoriasis skin biopsy image is the initial prerequisite for developing such system. However, the complex cellular structure, presence of imaging artifacts, uneven staining variation make the task challenging. This paper presents a pioneering attempt for automatic segmentation of psoriasis skin biopsy images. Several deep neural architectures are tried for segmenting psoriasis skin biopsy images. Deep models are used for classifying the super-pixels generated by Simple Linear Iterative Clustering (SLIC) and the segmentation performance of these architectures is compared with the traditional hand-crafted feature based classifiers built on popularly used classifiers like K-Nearest Neighbor (KNN), Support Vector Machine (SVM) and Random Forest (RF). A U-shaped Fully Convolutional Neural Network (FCN) is also used in an end to end learning fashion where input is the original color image and the output is the segmentation class map for the skin layers. An annotated real psoriasis skin biopsy image data set of ninety (90) images is developed and used for this research. The segmentation performance is evaluated with two metrics namely, Jaccard's Coefficient (JC) and the Ratio of Correct Pixel Classification (RCPC) accuracy. The experimental results show that the CNN based approaches outperform the traditional hand-crafted feature based classification approaches. The present research shows that practical system can be developed for machine assisted analysis of psoriasis disease. Copyright © 2018 Elsevier B.V. All rights reserved.

  11. Performance and Cost of Disposable Biopsy Forceps in Upper Gastrointestinal Endoscopy: Comparison with Reusable Biopsy Forceps

    PubMed Central

    Lim, Chul-Hyun; Kim, Won Chul; Kim, Jin Soo; Cho, Yu Kyung; Park, Jae Myung; Lee, In Seok; Kim, Sang Woo; Choi, Kyu Yong; Chung, In-Sik

    2012-01-01

    Background/Aims It is believed that disposable biopsy forceps are more costly than reusable biopsy forceps. In this study, we evaluated performance and cost of disposable forceps versus reusable forceps in esophagogastroduodenoscopic biopsy. Methods Between October 2009 and July 2010, we enrolled 200 patients undergoing esophagogastroduodenoscopic biopsy at Seoul St. Mary's Hospital. Biopsies were performed with 100 disposable or 5 reusable forceps by random assignment. Seventy-five additional patients were studied to estimate durability of reusable forceps. The assisting nurses estimated the performance of the forceps. The evaluation of costs included purchase prices and reprocessing costs. The adequacy of the sample was estimated according to the diameter of the obtained tissue. Results Performance of disposable forceps was estimated as excellent in 97.0%, good in 2.0% and adequate in 1.0%. Reusable forceps were estimated as excellent in 36.0%, good in 36.0%, adequate in 25.1% and inadequate in 2.9%. The performance of reusable forceps declined with the number of uses. The reprocessing cost of reusable forceps for one biopsy session was calculated as ₩8,021. The adequacy of the sample was excellent for both forceps. Conclusions Disposable forceps showed excellent performance. Considering the reprocessing costs of reusable forceps, usage of disposable forceps with a low price should be considered. PMID:22741133

  12. Comparison of intraocular pressure during the application of a liquid patient interface (FEMTO LDV Z8) for femtosecond laser-assisted cataract surgery using two different vacuum levels.

    PubMed

    Ebner, Martina; Mariacher, Siegfried; Januschowski, Kai; Boden, Katrin; Seuthe, Anna-Maria; Szurman, Peter; Boden, Karl Thomas

    2017-08-01

    To evaluate intraocular pressure (IOP) using the application of a novel liquid patient interface for femtosecond laser-assisted cataract surgery with the FEMTO LDV Z8. IOP was evaluated in enucleated porcine eyes prior, during and after the application of the Femto LDV Z8 liquid patient interface (Ziemer Ophthalmic Systems, Switzerland) using intracameral cannulation (n=20), intravitreal cannulation (n=20), rebound tonometry (n=20) and indentation tonometry (n=20). Pressure was assessed prior vacuum, during vacuum (30 s, 1 min, 2 min, 3 min) and after releasing the vacuum (1 min and 2 min). Two groups with different predefined vacuum levels (350 mbar, 420 mbar) were investigated. Mean intracameral pressure (±SD) increased during vacuum application from 20 mm Hg to 52.00 mm Hg (±6.35mm Hg; p=0.005) and 45.18 mmHg (±4.34 mm Hg; p=0.005) for the 420 mbar and the 350 mbar vacuum levels, respectively. Mean intravitreal pressure increased from 20 mm Hg to 25.60 mm Hg (±9.85 mm Hg; p=0.058) and 28.10 mm Hg (±2.54 mm Hg; p=0.059) for the 420 mbar and the 350 mbar vacuum levels, respectively. Pressure values from indentation and rebound tonometry were in between intracameral and intravitreal values. Mean intracameral IOP was 18.1% higher (p=0.019) in the 420 mbar group compared with the 350 mbar group. During vacuum application of the liquid patient interface of the Femto LDV Z8 for femtosecond laser-assisted cataract surgery, IOP values were higher in the anterior chamber compared with the intravitreal pressure measurements. The higher predefined vacuum level (350 mbar vs 420 mbar) resulted in significant higher intracameral IOP. © Article author(s) (or their employer(s) unless otherwise stated in the text of the article) 2017. All rights reserved. No commercial use is permitted unless otherwise expressly granted.

  13. Integrative analysis of copy number and gene expression in breast cancer using formalin-fixed paraffin-embedded core biopsy tissue: a feasibility study.

    PubMed

    Iddawela, Mahesh; Rueda, Oscar; Eremin, Jenny; Eremin, Oleg; Cowley, Jed; Earl, Helena M; Caldas, Carlos

    2017-07-11

    An absence of reliable molecular markers has hampered individualised breast cancer treatments, and a major limitation for translational research is the lack of fresh tissue. There are, however, abundant banks of formalin-fixed paraffin-embedded (FFPE) tissue. This study evaluated two platforms available for the analysis of DNA copy number and gene expression using FFPE samples. The cDNA-mediated annealing, selection, extension, and ligation assay (DASL™) has been developed for gene expression analysis and the Molecular Inversion Probes assay (Oncoscan™), were used for copy number analysis using FFPE tissues. Gene expression and copy number were evaluated in core-biopsy samples from patients with breast cancer undergoing neoadjuvant chemotherapy (NAC). Forty-three core-biopsies were evaluated and characteristic copy number changes in breast cancers, gains in 1q, 8q, 11q, 17q and 20q and losses in 6q, 8p, 13q and 16q, were confirmed. Regions that frequently exhibited gains in tumours showing a pathological complete response (pCR) to NAC were 1q (55%), 8q (40%) and 17q (40%), whereas 11q11 (37%) gain was the most frequent change in non-pCR tumours. Gains associated with poor survival were 11q13 (62%), 8q24 (54%) and 20q (47%). Gene expression assessed by DASL correlated with immunohistochemistry (IHC) analysis for oestrogen receptor (ER) [area under the curve (AUC) = 0.95], progesterone receptor (PR)(AUC = 0.90) and human epidermal growth factor type-2 receptor (HER-2) (AUC = 0.96). Differential expression analysis between ER+ and ER- cancers identified over-expression of TTF1, LAF-4 and C-MYB (p ≤ 0.05), and between pCR vs non-pCRs, over-expression of CXCL9, AREG, B-MYB and under-expression of ABCG2. This study was an integrative analysis of copy number and gene expression using FFPE core biopsies and showed that molecular marker data from FFPE tissues were consistent with those in previous studies using fresh-frozen samples. FFPE tissue can provide

  14. Comparison of Transjugular Liver Biopsy and Percutaneous Liver Biopsy With Tract Embolization in Pediatric Patients.

    PubMed

    Tulin-Silver, Sheryl; Obi, Chrystal; Kothary, Nishita; Lungren, Matthew

    2018-03-05

    The aim of the study was to compare safety and efficacy of transjugular liver biopsy (TJLB) and percutaneous liver biopsy (PLB) with tract embolization in pediatric patients with liver disease. TJLB and PLB between December 2009 and October 2015 were retrospectively reviewed. Primary endpoints were adequate sampling and complication rate. Patient age, weight, coagulation factors, ascites, blood transfusions, adequacy of biopsy sample, number of biopsy samples, and complications were compared. There were 39 TJLB (average age 10.6 years) and 120 PLB (average age 7.1 years) (P value <0.05). Average weight was 40.2 kg for TJLB and 26.8 kg for PLB (P value <0.05). Average platelets were 155 for TJLB and 252 for PLB (P value <0.05). Average INR was 1.7 for TJLB and 1.3 for PLB (P value <0.05). Mean postbiopsy hematocrit decrease was 0.8 and 0.9, for TJLB and PLB, respectively. Mean postbiopsy hemoglobin decrease was 0.3 in both groups. Number of core biopsy samples was 4.5 and 4.3, for TJLB and PLB, respectively. There was 1 biopsy yielding insufficient sample in each group. TJLB had 1 (2.6%) complication of supraventricular tachycardia. PLB had 4 (3.3%) complications, with 1 hemoperitoneum, 1 hypotension, 1 patient with decreased hemoglobin, and 1 patient with bilious drainage from the biopsy site. TJLB and PLB with gelatin sponge pledget tract embolization are both safe and effective for the diagnosis of hepatic disease in pediatric patients. To avoid radiation, PLB may be considered as first-line approach in the pediatric population, even in the setting of coagulopathy.

  15. Value of cytopathologist-performed ultrasound-guided fine-needle aspiration as a screening test for ultrasound-guided core-needle biopsy in nonpalpable breast masses.

    PubMed

    Lieu, David

    2009-04-01

    Fine-needle aspiration (FNA) of breast masses in the United States has been on the decline for the last decade and has been largely replaced by ultrasound-guided core-needle biopsy (UG-CNB). Some studies show core-needle biopsy (CNB) is superior to FNA in terms of absolute sensitivity, specificity, and inadequate rate. However, the importance of a skilled aspirator, experienced cytopathologist, and immediate cytological evaluation (ICE) in FNA is often not considered. CNB is more expensive, invasive, risky, and painful than FNA. This prospective study examines the value of cytopathologist-performed ultrasound-guided FNA (UG-FNA) with ICE as a screening test for cytopathologist-performed UG-CNB on nonpalpable or difficult-to-palpate solid breast masses visible on ultrasound. One hundred twenty consecutive nonpalpable or difficult-to-palpate presumably solid breast masses in 109 female patients from January2, 2008 to June 30, 2008 underwent cytopathologist-performed UG-FNA with ICE. Twenty cases were converted to cytopathologist-performed UG-CNB because ICE was inadequate, hypocellular, atypical, suspicious, or malignant. Patients with clearly benign cytology did not undergo UG-CNB. UG-FNA with ICE reduced the percentage of patients undergoing UG-CNB by 87%. A new role for cytopathologist-performed UG-FNA of nonpalpable breast masses has been identified.

  16. Computer assisted thermal-vacuum testing

    NASA Technical Reports Server (NTRS)

    Petrie, W.; Mikk, G.

    1977-01-01

    In testing complex systems and components under dynamic thermal-vacuum environments, it is desirable to optimize the environment control sequence in order to reduce test duration and cost. This paper describes an approach where a computer is utilized as part of the test control operation. Real time test data is made available to the computer through time-sharing terminals at appropriate time intervals. A mathematical model of the test article and environmental control equipment is then operated on using the real time data to yield current thermal status, temperature analysis, trend prediction and recommended thermal control setting changes to arrive at the required thermal condition. The data acquisition interface and the time-sharing hook-up to an IBM-370 computer is described along with a typical control program and data demonstrating its use.

  17. Use of the Prostate Core Mitomic Test in Repeated Biopsy Decision-Making: Real-World Assessment of Clinical Utility in a Multicenter Patient Population.

    PubMed

    Legisi, Lorena; DeSa, Elise; Qureshi, M Nasar

    2016-12-01

    Prostate cancer is the most common cancer diagnosed in men in developed countries. Using molecular testing may help to improve outcomes in this clinically challenging group. Since 2011, the Prostate Core Mitomic Test (PCMT), which quantifies a 3.4-kb mitochondrial DNA deletion strongly associated with prostate cancer, has been used by more than 50 urology practices accessing pathology services through our laboratory in New Jersey. However, the use of a molecular test can only be beneficial if it affects patient management and improves outcomes. To determine whether repeated biopsy decision-making was affected in a quantifiable manner through the adjunct use of molecular testing with the PCMT. In this observational study we conducted 2 independent, structured query language database queries of our patient records at our laboratory, QDx Pathology Services, in Cranford, NJ. Query 1 included all men who had a negative prostate biopsy and a negative PCMT between February 1, 2011, and June 30, 2013. Men with a previous diagnosis of cancer were excluded. Query 2 included all men who had a negative prostate biopsy and a repeated biopsy between February 1, 2011, and September 30, 2013. The data exported for each query included the unique specimen number for an index biopsy, the interval between biopsies where present, the unique specimen number for a follow-up biopsy where present, histopathology for all biopsies, the biopsy procedure dates, the patient's date of birth, and the PCMT result when utilized. The patient rebiopsy rates and intervals were compared between the patients who were using PCMT and those who were not to assess whether the adjunct use of the PCMT impacted the rebiopsy decision-making process. Query 1 identified 644 men who had a negative biopsy and a negative PCMT result within the study period. Query 2 identified 823 men with a repeat biopsy after the initial negative index biopsy within the study period. Of these men, 132 had PCMT to inform their care

  18. Core needle biopsy of soft tissue tumors, CEUS vs US guided: a pilot study.

    PubMed

    Coran, Alessandro; Di Maggio, Antonio; Rastrelli, Marco; Alberioli, Enrico; Attar, Shady; Ortolan, Paolo; Bortolanza, Carlo; Tosi, Annalisa; Montesco, Maria Cristina; Bezzon, Elisabetta; Rossi, Carlo Riccardo; Stramare, Roberto

    2015-12-01

    The purpose of this study was to evaluate the usefulness of contrast-enhanced ultrasonography (CEUS) in the bioptic sampling of soft tissue tumors (STT) compared with unenhanced ultrasonography alone. This is a prospective longitudinal study of 40 patients subjected to ultrasonography (US)-guided core needle biopsy (CNB) to characterize a suspected STT. Three series of bioptic samplings were carried out on each patient, respectively using unenhanced US alone and CEUS in both the areas of the tumor enhanced or not by the contrast medium. All bioptic samples underwent a histological evaluation and the results were analyzed by comparing the histology of the biopsy with the definitive diagnosis in 15 surgically excised samples. 27 (67.5 %) of the 40 patients completed the entire study procedure; in 19 cases (70.3 %) the three bioptic samplings gave unanimous results, also when compared to the surgical specimen; in seven cases (25.9 %) use of CEUS allowed to obtain additional or more accurate information about the mass in question, compared to simple US guidance without contrast; in one patient (3.7 %) sampling obtained using unenhanced ultrasonography guidance and in the areas enhanced by the contrast agent had precisely the same results of the surgical specimen. CEUS, due to its ability to evaluate microvascular areas, has proven to be a promising method in guiding bioptic sampling of soft tissue tumor, directing the needle to the most significant areas of the tumor. Given the small number of patients evaluated in our study, to achieve statistically significant results, it would be appropriate to obtain a larger sample size, since the very first results seem to be encouraging and to justify the increase of the population.

  19. Diclofenac Suppository as a Preemptive Analgesia in Ultrasound-guided Biopsy of Prostate: Randomized Controlled Trial.

    PubMed

    Haroon, Naveed; Ather, M Hammad; Khan, Salma; Kumar, Pirkash; Salam, Basit

    2015-10-01

    To compare preprocedure Diclofenac suppository and Xylocaine gel with Xylocaine gel only in patients undergoing transrectal ultrasound (TRUS)-guided biopsy of prostate for pain. It is a randomized controlled trial conducted on patients undergoing TRUS-guided biopsy for clinical or biochemical suspicion of prostate cancer following a written informed consent and Ethics Review Committee approval. Patients were randomized into 2 groups. Group A included those patients who received Diclofenac suppository 2 hours before in combination with 10 mL of 2% Xylocaine gel 5 minutes before biopsy. Group B received Xylocaine gel only. A visual analog scale was used to measure the pain scores at the time of TRUS probe insertion, just after taking biopsy cores and 2 hours after biopsy. A total of 100 patients were recruited in the study with 50 patients each in group A and B. Mean age of group A was 69.1 ± 10 years and 67.3 ± 8.1 years for group B. The mean pain score for group A and B at the time of probe insertion was 0.08 ± 0.27 and 0.34 ± 0.63 (P = .032), immediately after taking biopsy cores was 1.46 ± 1.15 and 4.68 ± 0.77 (P = .000), and 2 hours after biopsy was 0.14 ± 0.45 vs 2.40 ± 0.81 (P = .000), respectively. The mean pain score at the time of TRUS probe insertion, immediately after taking biopsy cores, and 2 hours after biopsy is statistically significantly higher in group B. Copyright © 2015 Elsevier Inc. All rights reserved.

  20. Real-time fluoroscopic needle guidance in the interventional radiology suite using navigational software for percutaneous bone biopsies in children.

    PubMed

    Shellikeri, Sphoorti; Setser, Randolph M; Hwang, Tiffany J; Srinivasan, Abhay; Krishnamurthy, Ganesh; Vatsky, Seth; Girard, Erin; Zhu, Xiaowei; Keller, Marc S; Cahill, Anne Marie

    2017-07-01

    Navigational software provides real-time fluoroscopic needle guidance for percutaneous procedures in the Interventional Radiology (IR) suite. We describe our experience with navigational software for pediatric percutaneous bone biopsies in the IR suite and compare technical success, diagnostic accuracy, radiation dose and procedure time with that of CT-guided biopsies. Pediatric bone biopsies performed using navigational software (Syngo iGuide, Siemens Healthcare) from 2011 to 2016 were prospectively included and anatomically matched CT-guided bone biopsies from 2008 to 2016 were retrospectively reviewed with institutional review board approval. C-arm CT protocols used for navigational software-assisted cases included institution-developed low-dose (0.1/0.17 μGy/projection), regular-dose (0.36 μGy/projection), or a combination of low-dose/regular-dose protocols. Estimated effective radiation dose and procedure times were compared between software-assisted and CT-guided biopsies. Twenty-six patients (15 male; mean age: 10 years) underwent software-assisted biopsies (15 pelvic, 7 lumbar and 4 lower extremity) and 33 patients (13 male; mean age: 9 years) underwent CT-guided biopsies (22 pelvic, 7 lumbar and 4 lower extremity). Both modality biopsies resulted in a 100% technical success rate. Twenty-five of 26 (96%) software-assisted and 29/33 (88%) CT-guided biopsies were diagnostic. Overall, the effective radiation dose was significantly lower in software-assisted than CT-guided cases (3.0±3.4 vs. 6.6±7.7 mSv, P=0.02). The effective dose difference was most dramatic in software-assisted cases using low-dose C-arm CT (1.2±1.8 vs. 6.6±7.7 mSv, P=0.001) or combined low-dose/regular-dose C-arm CT (1.9±2.4 vs. 6.6±7.7 mSv, P=0.04), whereas effective dose was comparable in software-assisted cases using regular-dose C-arm CT (6.0±3.5 vs. 6.6±7.7 mSv, P=0.7). Mean procedure time was significantly lower for software-assisted cases (91±54 vs. 141±68 min, P=0

  1. Pb(core)/ZnO(shell) nanowires obtained by microwave-assisted method

    PubMed Central

    2011-01-01

    In this study, Pb-filled ZnO nanowires [Pb(core)/ZnO(shell)] were synthesized by a simple and novel one-step vapor transport and condensation method by microwave-assisted decomposition of zinc ferrite. The synthesis was performed using a conventional oven at 1000 W and 5 min of treatment. After synthesis, a spongy white cotton-like material was obtained in the condensation zone of the reaction system. HRTEM analysis revealed that product consists of a Pb-(core) with (fcc) cubic structure that preferentially grows in the [111] direction and a hexagonal wurtzite ZnO-(Shell) that grows in the [001] direction. Nanowire length was more than 5 μm and a statistical analysis determined that the shell and core diameters were 21.00 ± 3.00 and 4.00 ± 1.00 nm, respectively. Experimental, structural details, and synthesis mechanism are discussed in this study. PMID:21985637

  2. Transrectal real-time tissue elastography targeted biopsy coupled with peak strain index improves the detection of clinically important prostate cancer.

    PubMed

    Ma, Qi; Yang, Dong-Rong; Xue, Bo-Xin; Wang, Cheng; Chen, Han-Bin; Dong, Yun; Wang, Cai-Shan; Shan, Yu-Xi

    2017-07-01

    The focus of the present study was to evaluate transrectal real-time tissue elastography (RTE)-targeted two-core biopsy coupled with peak strain index for the detection of prostate cancer (PCa) and to compare this method with 10-core systematic biopsy. A total of 141 patients were enrolled for evaluation. The diagnostic value of peak strain index was assessed using a receiver operating characteristic curve. The cancer detection rates of the two approaches and corresponding positive cores and Gleason score were compared. The cancer detection rate per core in the RTE-targeted biopsy (44%) was higher compared with that in systematic biopsy (30%). The peak strain index value of PCa was higher compared with that of the benign lesion. PCa was detected with the highest sensitivity (87.5%) and specificity (85.5%) using the threshold value of a peak strain index of ≥5.97 with an area under the curve value of 0.95. When the Gleason score was ≥7, RTE-targeted biopsy coupled with peak strain index detected 95.6% of PCa cases, but 84.4% were detected using systematic biopsy. Peak strain index as a quantitative parameter may improve the differentiation of PCa from benign lesions in the prostate peripheral zone. Transrectal RTE-targeted biopsy coupled with peak strain index may enhance the detection of clinically significant PCa, particularly when combined with systematic biopsy.

  3. Pseudoangiomatous Stromal Hyperplasia in Core Needle Biopsies of Breast Specimens.

    PubMed

    Kelten Talu, Canan; Boyaci, Ceren; Leblebici, Cem; Hacihasanoglu, Ezgi; Bozkurt, Erol Rustu

    2017-02-01

    Pseudoangiomatous stromal hyperplasia (PASH) is a benign lesion of myofibroblasts that is composed of a network of slit-like channels that resemble vascular spaces. The aims of this study were to document the frequency of PASH in core needle biopsy specimens (CNBS) of the breast, to describe which histopathologic findings coexist with PASH and to examine any endothelial cell differentiation. We reevaluated hematoxylin and eosin-stained sections of all CNBS that were obtained during a 1-year period. First, we performed CD34 and CD31 immunostainings to highlight the areas of PASH, then performed D2-40/podoplanin (lymphatic endothelial marker) and Fli-1 (vascular endothelial cell marker) immunostains. The total number of CNBS was 412. Areas of PASH were noted in 37 of the 412 cases (9%), with a mean age of 38.5 years. The lesions that were described in association with PASH were "benign breast parenchyma with stromal fibrosis" (17/37; 46%), "fibroepithelial tumors" (17/37; 46%), "columnar cell changes (CCC)" (2/37; 5%), and "invasive carcinoma" (1/37; 3%). There were 2 cases of CCC within the foci of PASH (direct contact with PASH), and 8 additional cases of CCC that coexisted in the same specimen but were not in direct contact. There was no staining for D2-40 or Fli-1 within PASH foci. PASH lesions occurred with a frequency of 9% in CNBS and were mostly in association with benign breast lesions in premenopausal women. CCC was determined as an accompanying epithelial lesion within or near PASH areas. No obvious immunopositivity compatible with endothelial cell differentiation was revealed.

  4. Automated real-time needle-guide tracking for fast 3-T MR-guided transrectal prostate biopsy: a feasibility study.

    PubMed

    Zamecnik, Patrik; Schouten, Martijn G; Krafft, Axel J; Maier, Florian; Schlemmer, Heinz-Peter; Barentsz, Jelle O; Bock, Michael; Fütterer, Jurgen J

    2014-12-01

    To assess the feasibility of automatic needle-guide tracking by using a real-time phase-only cross correlation ( POCC phase-only cross correlation ) algorithm-based sequence for transrectal 3-T in-bore magnetic resonance (MR)-guided prostate biopsies. This study was approved by the ethics review board, and written informed consent was obtained from all patients. Eleven patients with a prostate-specific antigen level of at least 4 ng/mL (4 μg/L) and at least one transrectal ultrasonography-guided biopsy session with negative findings were enrolled. Regions suspicious for cancer were identified on 3-T multiparametric MR images. During a subsequent MR-guided biopsy, the regions suspicious for cancer were reidentified and targeted by using the POCC phase-only cross correlation -based tracking sequence. Besides testing a general technical feasibility of the biopsy procedure by using the POCC phase-only cross correlation -based tracking sequence, the procedure times were measured, and a pathologic analysis of the biopsy cores was performed. Thirty-eight core samples were obtained from 25 regions suspicious for cancer. It was technically feasible to perform the POCC phase-only cross correlation -based biopsies in all regions suspicious for cancer in each patient, with adequate biopsy samples obtained with each biopsy attempt. The median size of the region suspicious for cancer was 8 mm (range, 4-13 mm). In each region suspicious for cancer (median number per patient, two; range, 1-4), a median of one core sample per region was obtained (range, 1-3). The median time for guidance per target was 1.5 minutes (range, 0.7-5 minutes). Nineteen of 38 core biopsy samples contained cancer. This study shows that it is feasible to perform transrectal 3-T MR-guided biopsies by using a POCC phase-only cross correlation algorithm-based real-time tracking sequence. © RSNA, 2014.

  5. Trans-rectal ultrasound visibility of prostate lesions identified by magnetic resonance imaging increases accuracy of image-fusion targeted biopsies.

    PubMed

    Ukimura, Osamu; Marien, Arnaud; Palmer, Suzanne; Villers, Arnauld; Aron, Manju; de Castro Abreu, Andre Luis; Leslie, Scott; Shoji, Sunao; Matsugasumi, Toru; Gross, Mitchell; Dasgupta, Prokar; Gill, Inderbir S

    2015-11-01

    To compare the diagnostic yield of targeted prostate biopsy using image-fusion of multi-parametric magnetic resonance (mp-MR) with real-time trans-rectal ultrasound (TRUS) for clinically significant lesions that are suspicious only on mp-MR versus lesions that are suspicious on both mp-MR and TRUS. Pre-biopsy MRI and TRUS were each scaled on a 3-point score: highly suspicious, likely, and unlikely for clinically significant cancer (sPCa). Using an MR-TRUS elastic image-fusion system (Koelis), a 127 consecutive patients with a suspicious clinically significant index lesion on pre-biopsy mp-MR underwent systematic biopsies and MR/US-fusion targeted biopsies (01/2010-09/2013). Biopsy histological outcomes were retrospectively compared with MR suspicion level and TRUS-visibility of the MR-suspicious lesion. sPCa was defined as biopsy Gleason score ≥7 and/or maximum cancer core length ≥5 mm. Targeted biopsies outperformed systematic biopsies in overall cancer detection rate (61 vs. 41 %; p = 0.007), sPCa detection rate (43 vs. 23 %; p = 0.0013), cancer core length (7.5 vs. 3.9 mm; p = 0.0002), and cancer rate per core (56 vs. 12 %; p < 0.0001), respectively. Highly suspicious lesions on mp-MR correlated with higher positive biopsy rate (p < 0.0001), higher Gleason score (p = 0.018), and greater cancer core length (p < 0.0001). Highly suspicious lesions on TRUS in corresponding to MR-suspicious lesion had a higher biopsy yield (p < 0.0001) and higher sPCa detection rate (p < 0.0001). Since majority of MR-suspicious lesions were also suspicious on TRUS, TRUS-visibility allowed selection of the specific MR-visible lesion which should be targeted from among the multiple TRUS suspicious lesions in each prostate. MR-TRUS fusion-image-guided biopsies outperformed systematic biopsies. TRUS-visibility of a MR-suspicious lesion facilitates image-guided biopsies, resulting in higher detection of significant cancer.

  6. Biopsy Findings After Breast Conservation Therapy for Early-Stage Invasive Breast Cancer

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Vapiwala, Neha; Starzyk, Jill; Harris, Eleanor E.

    2007-10-01

    Purpose: To determine the patterns and factors predictive of positive ipsilateral breast biopsy after conservation therapy for early-stage breast cancer. Methods and Materials: We performed a retrospective review of Stage I-II breast cancer patients initially treated with lumpectomy and radiotherapy between 1977 and 1996, who later underwent post-treatment ipsilateral breast biopsies. Results: A total of 223 biopsies were performed in 193 treated breasts: 171 single and 22 multiple biopsies. Of the 223 biopsies, 56% were positive and 44% were negative for recurrence. The positive biopsy rate (PBR) was 59% for the first and 32% for subsequent biopsies. The median timemore » to the first post-treatment biopsy was 49 months. Of the patients with negative initial biopsy findings, 11% later developed local recurrence. The PBR was 40% among patients with physical examination findings only, 65% with mammographic abnormalities only, and 79% with both findings (p = 0.001). Analysis of the procedure type revealed a PBR of 86% for core and 58% for excisional biopsies compared with 28% for aspiration cytology alone (p = 0.025). The PBR varied inversely with age at the original diagnosis: 49% if {>=}51 years, 57% if 36-50 years, and 83% if {<=}35 years (p = 0.05). The PBR correlated directly with the interval after radiotherapy: 49% if {<=}60 months, 59% if 60.1-120 months, 77% if 120.1-180 months, and 100% if >180 months after completing postlumpectomy radiotherapy (p = 0.01). The PBR was not linked with recurrence location, initial pathologic T or N stage, estrogen receptor/progesterone receptor status, or final pathologic margins (all p {>=} 0.15). Conclusion: After definitive radiotherapy for early-stage breast cancer, a greater PBR was associated with the presence of both mammographic and clinical abnormalities, excisional or core biopsies, younger age at the initial diagnosis, and longer intervals after radiotherapy completion.« less

  7. Identification of threshold prostate specific antigen levels to optimize the detection of clinically significant prostate cancer by magnetic resonance imaging/ultrasound fusion guided biopsy.

    PubMed

    Shakir, Nabeel A; George, Arvin K; Siddiqui, M Minhaj; Rothwax, Jason T; Rais-Bahrami, Soroush; Stamatakis, Lambros; Su, Daniel; Okoro, Chinonyerem; Raskolnikov, Dima; Walton-Diaz, Annerleim; Simon, Richard; Turkbey, Baris; Choyke, Peter L; Merino, Maria J; Wood, Bradford J; Pinto, Peter A

    2014-12-01

    Prostate specific antigen sensitivity increases with lower threshold values but with a corresponding decrease in specificity. Magnetic resonance imaging/ultrasound targeted biopsy detects prostate cancer more efficiently and of higher grade than standard 12-core transrectal ultrasound biopsy but the optimal population for its use is not well defined. We evaluated the performance of magnetic resonance imaging/ultrasound targeted biopsy vs 12-core biopsy across a prostate specific antigen continuum. We reviewed the records of all patients enrolled in a prospective trial who underwent 12-core transrectal ultrasound and magnetic resonance imaging/ultrasound targeted biopsies from August 2007 through February 2014. Patients were stratified by each of 4 prostate specific antigen cutoffs. The greatest Gleason score using either biopsy method was compared in and across groups as well as across the population prostate specific antigen range. Clinically significant prostate cancer was defined as Gleason 7 (4 + 3) or greater. Univariate and multivariate analyses were performed. A total of 1,003 targeted and 12-core transrectal ultrasound biopsies were performed, of which 564 diagnosed prostate cancer for a 56.2% detection rate. Targeted biopsy led to significantly more upgrading to clinically significant disease compared to 12-core biopsy. This trend increased more with increasing prostate specific antigen, specifically in patients with prostate specific antigen 4 to 10 and greater than 10 ng/ml. Prostate specific antigen 5.2 ng/ml or greater captured 90% of upgrading by targeted biopsy, corresponding to 64% of patients who underwent multiparametric magnetic resonance imaging and subsequent fusion biopsy. Conversely a greater proportion of clinically insignificant disease was detected by 12-core vs targeted biopsy overall. These differences persisted when controlling for potential confounders on multivariate analysis. Prostate cancer upgrading with targeted biopsy increases

  8. Mammotome-Assisted Liposuction: A Novel Technique for Accessory Breasts.

    PubMed

    Tang, Xin

    2017-06-01

    Due to its minimally invasive and highly precise nature, the mammotome, a vacuum-assisted breast biopsy device, has proven effective for the treatment of benign breast lesions. Taking advantage of both liposuction and the mammotome, we utilized the mammotome device for the excision of accessory breasts. Between July 2010 and June 2014, 16 patients with accessory breasts received mammotome-assisted liposuction. After adipose was removed using this procedure, the mammotome system was used to excise the fibro-glandular tissue in accessory breasts under ultrasound monitoring. All patients were satisfied with their appearance after surgery. A single 5-mm incision, which was well hidden in the axillary skin folds and allowed for restoration, provided an aesthetically pleasing contour to the axilla. Mammotome-assisted liposuction is a new approach that can be used to excise both adipose and fibro-glandular breast tissue simultaneously with a minimal incision, and provides a favorable contour to the axilla. This journal requires that authors assign a level of evidence to each article. For a full description of these Evidence-Based Medicine ratings, please refer to the Table of Contents or the online Instructions to Authors www.springer.com/00266 .

  9. Ultrasound-Guided Percutaneous Thyroid Nodule Core Biopsy: Clinical Utility in Patients with Prior Nondiagnostic Fine-Needle Aspirate

    PubMed Central

    Vij, Abhinav; Seale, Melanie K.; Desai, Gaurav; Halpern, Elkan; Faquin, William C.; Parangi, Sareh; Hahn, Peter F.; Daniels, Gilbert H.

    2012-01-01

    Background Five percent to 20% of thyroid nodule fine-needle aspiration (FNA) samples are nondiagnostic. The objective of this study was to determine whether a combination of FNA and core biopsy (CFNACB) would yield a higher proportion of diagnostic readings compared with FNA alone in patients with a history of one or more prior nondiagnostic FNA readings. Methods We conducted a retrospective study of 90 core biopsies (CBs) performed in 82 subjects (55 women and 27 men) between 2006 and 2008 in an outpatient clinic. Results CFNACB yielded a diagnostic reading in 87%. The diagnostic reading yield of the CB component of CFNACB was significantly superior to the concurrent FNA component, with CB yielding a diagnosis in 77% of cases and FNA yielding a diagnosis in 47% (p<0.0001). The combination of CB and FNA had a higher diagnostic reading yield than either alone. In 69 nodules that had only one prior nondiagnostic FNA, CB was diagnostic in 74%, FNA was diagnostic in 52%, CFNACB was diagnostic in 87%, and CB performed significantly better than FNA (p=0.0135). In 21 nodules with two or more prior nondiagnostic FNAs, CFNACB and CB were diagnostic in 86%, FNA was diagnostic in 29%, and CB was significantly better than FNA (p=0.0005). Clinical, ultrasound, or histopathologic follow-up was available for 81% (73/90) of the CFNACB procedures. No subject with a benign CFNACB reading was diagnosed with thyroid malignancy in the follow-up period (range 4–37 months, mean 18 months), although one subject had minimal increase in nodule size and was awaiting repeat sonography at study conclusion. Conclusion Thyroid nodule CFNACB is safe and clinically useful in selected patients when a prior FNA reading is nondiagnostic. CFNACB is superior to either CB or FNA alone. CFNACB should be strongly considered as an alternative to surgery in individuals with two prior nondiagnostic FNAs. PMID:22304390

  10. Transjugular Renal Biopsy: Our Experience and Technical Considerations

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    See, Teik Choon, E-mail: teikchoon.see@addenbrookes.nhs.u; Thompson, Barbara C.; Howie, Alexander J.

    2008-09-15

    The purpose of this study was to describe the indications for and technique of transjugular renal biopsy (TJRB) and evaluate the efficacy and complications of this method. We performed a retrospective review of 59 patients who underwent TJRB using the Quick-core needle biopsy system (Cook, Letchworth, UK) over a 4-year period. The indications for obtaining renal biopsy included acute renal failure, chronic renal failure, nephrotic syndrome, and proteinuria with or without other associated disease. Indications for the transjugular approach included coagulopathy, biopsy of a solitary kidney or essentially single functioning kidney, simultaneous renal and hepatic biopsy, morbid obesity, and failedmore » percutaneous biopsy. All but four cases were performed via the right internal jugular vein. The right, left, or both renal veins were cannulated in 41, 14, and 4 cases, respectively. Combined liver and renal biopsies were obtained in seven cases. Diagnostic biopsy specimens were obtained in 56 of 59 patients (95%). The number and size of tissue cores ranged from 1 to 9 mm and from 1 to 20 mm, respectively. The mean numbers of glomeruli per procedure on light microscopy and electron microscopy were 10.3 and 2.6, respectively. Specimens for immunohistology were acquired in 49 cases, of which 40 were adequate. Of the 56 successful TJRB procedures, 34 (61%) were associated with isolated capsular perforation (19), contained subcapsular leak (10), isolated collecting system puncture (1), and concurrent collecting system and capsular perforation (4). There was a significant increase in capsular perforation with six or more needle passes, although no significant correlation was seen between number of needle passes and complication. Six patients had minor complications defined as hematuria or loin pain. Seven patients developed major complications, of whom five received blood transfusion alone. Two required intervention: in one an arteriocalyceal fistula was embolized and the

  11. Intrapartum translabial ultrasound with pushing used to predict the difficulty in vacuum-assisted delivery of fetuses in non-occiput posterior position.

    PubMed

    Antonio Sainz, José; Borrero, Carlota; Aquise, Adriana; García-Mejido, José Antonio; Gutierrez, Laura; Fernández-Palacín, Ana

    2016-10-01

    Our aim is to evaluate the capacity of intrapartum translabial ultrasound (ITU) with pushing in the prediction of difficulty of fetal extraction in vacuum assisted deliveries. Prospective, observational study performed (2/2015-8/2015) on 75 nulliparous women, ≥37 weeks with singleton pregnancies at full dilatation who had ITU-with-pushing performed, previous to vacuum-placement for fetal extraction. Working on the translabial sagittal-plane, we assessed: Angle-Progression (AoP), Progression-Distance (PD) and Head-Direction (HD); in the axial plane we evaluated: Midline-Angle (MLA) and Head-Perineum-Distance (HPD). Vacuum extractions were classified as easy-difficulty (ED) (≤3 vacuum-pulls), difficult-unsuccessful (DD) (>3 vacuum-pulls). We did not assess occipito-posterior-presentations. Seventy nulliparous were studied (44-ED,26-DD). We observed no differences in obstetric, neonatal or intrapartum characteristics between the two study groups, with the following exceptions: newborn weight (3272 ± 438 g versus 3540 ± 372 g; p = 0.011) and number of vacuum-pulls (1.4-ED-vs-4.4-DD; p < 0.0005). AoP-pushing was 143.9° ± 14.6° in ED and 115.1°± 12.9° in DD (p < 0.0005); Head-Up was 79.5% versus 38.4% (p < 0.0005); PD-Pushing was 42.7 ± 11.3 mm versus 30.4 ± 9.8 mm (p < 0.0005); MLA-Pushing was 27.6°± 26.6° versus 57.5°±26.5°(p=0.025); HPD-Pushing was 40.8 ± 10.0 mm versus 47.4 ± 10.9 mm (p = 0.039). We identified that the presence of an AoP-Pushing > 128° predicts an Easy-Vacuum-Delivery (≤3 Vacuum-Pulls) in  >85% of cases (Sen 80%-FPR 9.3%).

  12. [Caesarean section with vacuum extraction of the head].

    PubMed

    Dimitrov, A; Pavlova, E; Krŭsteva, K; Nikolov, A

    2008-01-01

    The aim of the study is to investigate the benefits and the limits in using the soft cup vacuum extractor on the fetal scalp during the caesarean section. The prospective study includes 19 cases of caesarean sections (group A), with vacuum assisted delivery using the soft cup vacuum extractor on the fetal scalp (diameter 6 cm) and 25 cases (group B) of caesarean sections with usual, manual extraction of the head assisted by fundal compression. All of the patients had undergone a planned caesarean section on term in absence of uterine activity and preserved amniotic membranes. Our results doesn't show differences in the Apgar score on the first and 5-th minute in the newborns of the two groups. The duration of the scalp traction was significantly shorter (30 +/- 4 sec) in comparison to the classical manual extraction (53 +/- 21 sec). The mean duration for applying the vacuum cup was 10 sec and 25 sec for tractions. The total blood loose and total duration of the caesarean sections were shorter than in the control group. The applied traction with the vacuum cup was sufficient for head extraction and there was no need for additional fundal compression. In conclusion we consider that the extraction of the fetal head in high position in caesarean section with vacuum extractor is an easy, non traumatic and rapid method which can put away the need of rough and prolonged fundal compression and its consequences.

  13. Diagnostic Yield of CT-Guided Percutaneous Transthoracic Needle Biopsy for Diagnosis of Anterior Mediastinal Masses.

    PubMed

    Petranovic, Milena; Gilman, Matthew D; Muniappan, Ashok; Hasserjian, Robert P; Digumarthy, Subba R; Muse, Victorine V; Sharma, Amita; Shepard, Jo-Anne O; Wu, Carol C

    2015-10-01

    The purpose of this study was to evaluate the diagnostic yield and accuracy of CT-guided percutaneous biopsy of anterior mediastinal masses and assess prebiopsy characteristics that may help to select patients with the highest diagnostic yield. Retrospective review of all CT-guided percutaneous biopsies of the anterior mediastinum conducted at our institution from January 2003 through December 2012 was performed to collect data regarding patient demographics, imaging characteristics of biopsied masses, presence of complications, and subsequent surgical intervention or medical treatment (or both). Cytology, core biopsy pathology, and surgical pathology results were recorded. A per-patient analysis was performed using two-tailed t test, Fisher's exact test, and Pearson chi-square test. The study cohort included 52 patients (32 men, 20 women; mean age, 49 years) with mean diameter of mediastinal mass of 6.9 cm. Diagnostic yield of CT-guided percutaneous biopsy was 77% (40/52), highest for thymic neoplasms (100% [11/11]). Non-diagnostic results were seen in 12 of 52 patients (23%), primarily in patients with lymphoma (75% [9/12]). Fine-needle aspiration yielded the correct diagnosis in 31 of 52 patients (60%), and core biopsy had a diagnostic rate of 77% (36/47). None of the core biopsies were discordant with surgical pathology. There was no statistically significant difference between the diagnostic and the nondiagnostic groups in patient age, lesion size, and presence of necrosis. The complication rate was 3.8% (2/52), all small self-resolving pneumothoraces. CT-guided percutaneous biopsy is a safe diagnostic procedure with high diagnostic yield (77%) for anterior mediastinal lesions, highest for thymic neoplasms (100%), and can potentially obviate more invasive procedures.

  14. The efficacy of oral brush biopsy with computer-assisted analysis in identifying precancerous and cancerous lesions

    PubMed Central

    2011-01-01

    Background Cancer of the oral cavity is the sixth most common malignancy reported worldwide and one with the highest mortality rate among all malignancies. There is a paucity of reliable diagnostic methods to detect early malignancies. This study was performed to evaluate the sensitivity and specificity of brush biopsy in identifying oral premalignant and malignant lesions. Methods Oral brush and scalpel biopsies were performed on 85 consecutive patients presenting with an oral lesion deemed to be minimally suspicious by clinical examination and the results were compared. Results Of 79 patients with adequate brush biopsy samples with matching scalpel biopsies, 27 revealed histopathologic evidence of dysplasia or carcinoma, 26 of which were independently identified with the oral brush biopsy (sensitivity: 96.3% - 95% CI, 87%-100%). 52 oral lesions did not reveal any histopathologic evidence of dysplasia or carcinoma and of these, brush biopsy reported 47 as "negative" and 5 as "atypical"(specificity of "positive" brush biopsy result is 100%- 95% CI, 93%-100%; specificity for "atypical" brush biopsy result is 90.4%- 95% CI, 82%-97%. The positive predictive value of an abnormal oral brush biopsy was 84% and the negative predictive value was 98%. Conclusion Our study demonstrated that the oral brush biopsy is an accurate test in identifying oral premalignant and malignant lesions, even if minimally suspicious. PMID:21864339

  15. Single-Pass Percutaneous Liver Biopsy for Diffuse Liver Disease Using an Automated Device: Experience in 154 Procedures

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Rivera-Sanfeliz, Gerant, E-mail: gerantrivera@ucsd.edu; Kinney, Thomas B.; Rose, Steven C.

    2005-06-15

    Purpose: To describe our experience with ultrasound (US)-guided percutaneous liver biopsies using the INRAD 18G Express core needle biopsy system.Methods: One hundred and fifty-four consecutive percutaneous core liver biopsy procedures were performed in 153 men in a single institution over 37 months. The medical charts, pathology reports, and radiology files were retrospectively reviewed. The number of needle passes, type of guidance, change in hematocrit level, and adequacy of specimens for histologic analysis were evaluated.Results: All biopsies were performed for histologic staging of chronic liver diseases. The majority of patients had hepatitis C (134/153, 90.2%). All patients were discharged to homemore » after 4 hr of postprocedural observation. In 145 of 154 (94%) biopsies, a single needle pass was sufficient for diagnosis. US guidance was utilized in all but one of the procedures (153/154, 99.4%). The mean hematocrit decrease was 1.2% (44.1-42.9%). Pain requiring narcotic analgesia, the most frequent complication, occurred in 28 of 154 procedures (18.2%). No major complications occurred. The specimens were diagnostic in 152 of 154 procedures (98.7%).Conclusions: Single-pass percutaneous US-guided liver biopsy with the INRAD 18G Express core needle biopsy system is safe and provides definitive pathologic diagnosis of chronic liver disease. It can be performed on an outpatient basis. Routine post-biopsy monitoring of hematocrit level in stable, asymptomatic patients is probably not warranted.« less

  16. Clinical utility of transperineal template-guided mapping biopsy of the prostate after negative magnetic resonance imaging-guided transrectal biopsy.

    PubMed

    Sivaraman, Arjun; Sanchez-Salas, Rafael; Ahmed, Hashim U; Barret, Eric; Cathala, Nathalie; Mombet, Annick; Uriburu Pizarro, Facundo; Carneiro, Arie; Doizi, Steeve; Galiano, Marc; Rozet, Francois; Prapotnich, Dominique; Cathelineau, Xavier

    2015-07-01

    We evaluated the prostate cancer detection with transperineal template-guided mapping biopsy in patients with elevated prostate-specific antigen and negative magnetic resonance imaging (MRI)-guided biopsy. Totally 75 patients underwent transperineal template-guided mapping biopsy for prior negative MRI-guided (cognitive registration) biopsy during April 2013 to August 2014. Primary objective was to report clinically significant cancer detection in this cohort of patients. Significant cancer was defined using varying thresholds of MCL or Gleason grade 3+4 or greater or both. Cancers with more than 80% of positive core length anterior to the level of urethra were termed anterior zone cancer. Secondary objective was to evaluate the potential clinical and radiological predictors for significant cancer detection. The mean age was 61.6 ± 6.5 years and median prostate-specific antigen was 10.4 ng/dl (7.9-18) with a mean MRI target size of 7.2mm (4-11). Transperineal template-guided mapping biopsy identified cancer in 36% (27/75) patients and 66.6% (18/27) of them were anterior zone cancers. The rates of detection of clinically significant and insignificant cancer according to the several definitions used range from 22.7% to 30.7% and 5.3% to 13.3%, respectively. Multivariate analysis did not identify any predictors for finding clinically significant and anterior cancers in this group of patients. Transperineal template-guided mapping biopsy appears to be an excellent biopsy protocol for downstream management following negative MRI-guided biopsy. Most of the cancers detected were predominantly anterior tumors. Copyright © 2015 Elsevier Inc. All rights reserved.

  17. Percutaneous Biopsy of Retrobulbar Masses: Anatomical Considerations and MRI Guidance

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Edalat, Faramarz, E-mail: faramarz.edalat@gmail.com; Cazzato, Roberto Luigi; Garnon, Julien

    2017-04-15

    PurposeObtaining adequate tissue from retrobulbar masses remains a challenge. To this end, a new method of retrobulbar mass biopsy using MRI guidance is presented.Materials and MethodsTwo patients (7- and 71-year-old male) with indeterminate retrobulbar masses underwent bioptic and cytological samplings using MR-compatible 18G and 20–22G needles, and multi-planar MR fluoroscopy. An inferior approach was taken to avoid injury to the optic nerve and ophthalmic arteries.ResultsThe two biopsies were completed without complication. The core biopsy resulted in a final diagnosis, whereas the cytological sampling was non-diagnostic.ConclusionPercutaneous MR-guided retrobulbar mass biopsy proved to be feasible and safe in the two cases describedmore » in this report.« less

  18. Long-term clinical evaluation of a 800-nm long-pulsed diode laser with a large spot size and vacuum-assisted suction for hair removal.

    PubMed

    Ibrahimi, Omar A; Kilmer, Suzanne L

    2012-06-01

    The long-pulsed diode (800-810-nm) laser is one of the most commonly used and effective lasers for hair removal. Limitations of currently available devices include a small treatment spot size, treatment-associated pain, and the need for skin cooling. To evaluate the long-term hair reduction capabilities of a long-pulsed diode laser with a large spot size and vacuum assisted suction. Thirty-five subjects were enrolled in a prospective, self-controlled, single-center study of axillary hair removal. The study consisted of three treatments using a long-pulsed diode laser with a large spot size and vacuum-assisted suction at 4- to 6-week intervals with follow-up visits 6 and 15 months after the last treatment. Hair clearance was quantified using macro hair-count photographs taken at baseline and at 6- and 15-month follow-up visits. Changes in hair thickness and color, levels of treatment-associated pain, and adverse events were additional study endpoints. There was statistically significant hair clearance at the 6 (54%) and 15-month (42%) follow-up visits. Remaining hairs were thinner and lighter at the 15-month follow-up visit, and the majority of subjects reported feeling up to mild to moderate pain during treatment without the use of pretreatment anesthesia or skin cooling. A long-pulsed diode laser with a large spot size and vacuum-assisted suction is safe and effective for long-term hair removal. This is the largest prospective study to evaluate long-term hair removal and the first to quantify decreases in hair thickness and darkness with treatment. © 2012 by the American Society for Dermatologic Surgery, Inc. Published by Wiley Periodicals, Inc.

  19. Computerized transrectal ultrasound (C-TRUS) of the prostate: detection of cancer in patients with multiple negative systematic random biopsies.

    PubMed

    Loch, Tillmann

    2007-08-01

    This study was designed to compare the diagnostic yield of computerized transrectal ultrasound (C-TRUS) guided biopsies in the detection of prostate cancer in a group of men with a history of multiple systematic random biopsies with no prior evidence of prostate cancer. The question was asked: Can we detect cancer by C-TRUS that has been overlooked by multiple systematic biopsies? The entrance criteria for this study were prior negative systematic random biopsies regardless of number of biopsy sessions or number of individual biopsy cores. Serial static TRUS images were evaluated by C-TRUS, which assessed signal information independent of visual gray scale. Five C-TRUS algorithms were utilized to evaluate the information of the ultrasound signal. Interpretation of the results were documented and the most suspicious regions marked by C-TRUS were biopsied by guiding the needle to the marked location. Five hundred and forty men were biopsied because of an elevated PSA or abnormal digital rectal exam. 132 had a history of prior negative systematic random biopsies (1-7 sessions, median: 2 and between 6 and 72 individual prostate biopsies, median: 12 cores). Additionally, a diagnostic TUR-P of the prostate with benign result was performed in four patients. The PSA ranged from 3.1-36 ng/ml with a median of 9.01 ng/ml. The prostate volume ranged from 6-203 ml with a median of 42 ml. Of the 132 patients with prior negative systematic random biopsies, cancer was found in 66 (50%) by C-TRUS targeted biopsies. In this group the median number of negative biopsy sessions was two and a median of 12 biopsy cores were performed. From literature we would expect a cancer detection rate in this group with systematic biopsies of approximately 7%. We only found five carcinomas with a Gleason Score (GS) of 5, 25 with GS 6, 22 with GS 7, 8 with GS 8 and even 7 with GS 9. The results of this prospective clinical trail indicates that the additional use of the C-TRUS identifies clinical

  20. A vacuum flash-assisted solution process for high-efficiency large-area perovskite solar cells

    NASA Astrophysics Data System (ADS)

    Li, Xiong; Bi, Dongqin; Yi, Chenyi; Décoppet, Jean-David; Luo, Jingshan; Zakeeruddin, Shaik Mohammed; Hagfeldt, Anders; Grätzel, Michael

    2016-07-01

    Metal halide perovskite solar cells (PSCs) currently attract enormous research interest because of their high solar-to-electric power conversion efficiency (PCE) and low fabrication costs, but their practical development is hampered by difficulties in achieving high performance with large-size devices. We devised a simple vacuum flash-assisted solution processing method to obtain shiny, smooth, crystalline perovskite films of high electronic quality over large areas. This enabled us to fabricate solar cells with an aperture area exceeding 1 square centimeter, a maximum efficiency of 20.5%, and a certified PCE of 19.6%. By contrast, the best certified PCE to date is 15.6% for PSCs of similar size. We demonstrate that the reproducibility of the method is excellent and that the cells show virtually no hysteresis. Our approach enables the realization of highly efficient large-area PSCs for practical deployment.

  1. Categorizing renal oncocytic neoplasms on core needle biopsy: a morphologic and immunophenotypic study of 144 cases with clinical follow-up. Alderman MA, Daignault S, Wolf JS Jr, Palapattu GS, Weizer AZ, Hafez KS, Kunju LP, Wu AJ. Hum Pathol.September 2016;55:1-10.

    PubMed

    Kryvenko, Oleksandr N

    2017-06-01

    There is limited literature on renal oncocytic neoplasms diagnosed on core biopsy. All renal oncocytic neoplasm core biopsies from 2006 to 2013 were, retrospectively, reviewed. Morphologic features and an immunohistochemical panel of CK7, c-KIT, and S100A1 were assessed. Concordance with resection diagnosis, statistical analysis including a random forest classification, and follow-up were recorded. The postimmunohistochemical diagnoses of 144 renal oncocytic core biopsies were favor oncocytoma (67%), favor renal cell carcinoma (RCC) (12%), and cannot exclude RCC (21%). Diagnosis was revised following immunohistochemistry in 7% of cases. The most common features for oncocytoma (excluding dense granular cytoplasm) were nested architecture, edematous stroma, binucleation and tubular architecture; the most common features for favor RCC were sheet-like architecture, nuclear pleomorphism, papillary architecture, and prominent cell borders. High nuclear grade, necrosis, extensive papillary architecture, raisinoid nuclei, and frequent mitoses were not seen in oncocytomas. Comparing the pathologist and random forest classification, the overall out-of-bag estimate of classification error dropped from 23% to 13% when favor RCC and cannot exclude RCC was combined into 1 category. Resection was performed in 19% (28 cases) with a 94% concordance (100% of favor RCC biopsies and 90% of cannot exclude RCC biopsies confirmed as RCC; 83% of favor oncocytomas confirmed); ablation in 23%; and surveillance in 46%. Follow-up was available in 92% (median follow-up, 33 months) with no adverse outcomes. Renal oncocytic neoplasms comprise a significant subset (16%) of all core biopsies, and the majority (78%) can be classified as favor oncocytoma or favor RCC. Copyright © 2017 Elsevier Inc. All rights reserved.

  2. High risk of fistula formation in vacuum-assisted closure therapy in patients with open abdomen due to secondary peritonitis-a retrospective analysis.

    PubMed

    Mintziras, Ioannis; Miligkos, Michael; Bartsch, Detlef Klaus

    2016-08-01

    The aim of this study was to evaluate the efficacy of vacuum-assisted closure therapy in patients with open abdomen due to secondary peritonitis and to identify possible risk factors of fistula formation. The hospital OPS-database (time period 2005-2014) was searched to identify patients treated with an open abdomen due to secondary peritonitis, who underwent vacuum-assisted closure therapy. Medical records were retrospectively analyzed for patients' characteristics, cause of peritonitis, duration of vacuum therapy, number of relaparotomies, fascial closure rates, and risk factors of fistula formation. Forty-three patients (19 male, 24 female) with a median age of 65 years (range 24-90 years) were identified. The major cause of secondary peritonitis was anastomotic leakage after intestinal anastomosis or bowel perforation, the median APACHE II score was 11. Median duration of VAC treatment was 12 days (range 3-88 days). Twenty of 43 (47 %) patients died from septic complications. Delayed fascial closure was obtained by suturing in 20 of 43 patients (47 %). Overall 16 of 43 (37 %) patients developed enteroatmospheric fistulas. Re-explorations after starting VAC treatment and duration of VAC therapy were significantly associated with the occurrence of enteroatmospheric fistulas (p < 0.001). ROC curve analysis determined the optimal duration of VAC therapy to reduce the risk of fistula formation at 13 days. Long-term VAC treatment of patients with an open abdomen due to secondary peritonitis results in a relatively low fascial closure rate and a high risk of fistula formation.

  3. Relationship Between Prebiopsy Multiparametric Magnetic Resonance Imaging (MRI), Biopsy Indication, and MRI-ultrasound Fusion-targeted Prostate Biopsy Outcomes.

    PubMed

    Meng, Xiaosong; Rosenkrantz, Andrew B; Mendhiratta, Neil; Fenstermaker, Michael; Huang, Richard; Wysock, James S; Bjurlin, Marc A; Marshall, Susan; Deng, Fang-Ming; Zhou, Ming; Melamed, Jonathan; Huang, William C; Lepor, Herbert; Taneja, Samir S

    2016-03-01

    Increasing evidence supports the use of magnetic resonance imaging (MRI)-ultrasound fusion-targeted prostate biopsy (MRF-TB) to improve the detection of clinically significant prostate cancer (PCa) while limiting detection of indolent disease compared to systematic 12-core biopsy (SB). To compare MRF-TB and SB results and investigate the relationship between biopsy outcomes and prebiopsy MRI. Retrospective analysis of a prospectively acquired cohort of men presenting for prostate biopsy over a 26-mo period. A total of 601 of 803 consecutively eligible men were included. All men were offered prebiopsy MRI and assigned a maximum MRI suspicion score (mSS). Men with an MRI abnormality underwent combined MRF-TB and SB. Detection rates for all PCa and high-grade PCa (Gleason score [GS] ≥7) were compared using the McNemar test. MRF-TB detected fewer GS 6 PCas (75 vs 121; p<0.001) and more GS ≥7 PCas (158 vs 117; p<0.001) than SB. Higher mSS was associated with higher detection of GS ≥7 PCa (p<0.001) but was not correlated with detection of GS 6 PCa. Prediction of GS ≥7 disease by mSS varied according to biopsy history. Compared to SB, MRF-TB identified more GS ≥7 PCas in men with no prior biopsy (88 vs 72; p=0.012), in men with a prior negative biopsy (28 vs 16; p=0.010), and in men with a prior cancer diagnosis (42 vs 29; p=0.043). MRF-TB detected fewer GS 6 PCas in men with no prior biopsy (32 vs 60; p<0.001) and men with prior cancer (30 vs 46; p=0.034). Limitations include the retrospective design and the potential for selection bias given a referral population. MRF-TB detects more high-grade PCas than SB while limiting detection of GS 6 PCa in men presenting for prostate biopsy. These findings suggest that prebiopsy multiparametric MRI and MRF-TB should be considered for all men undergoing prostate biopsy. In addition, mSS in conjunction with biopsy indications may ultimately help in identifying men at low risk of high-grade cancer for whom prostate biopsy

  4. Magnetic resonance/transrectal ultrasound fusion biopsy of the prostate compared to systematic 12-core biopsy for the diagnosis and characterization of prostate cancer: multi-institutional retrospective analysis of 389 patients.

    PubMed

    Mariotti, Guilherme C; Costa, Daniel N; Pedrosa, Ivan; Falsarella, Priscila M; Martins, Tatiana; Roehrborn, Claus G; Rofsky, Neil M; Xi, Yin; M Andrade, Thais C; Queiroz, Marcos R; Lotan, Yair; Garcia, Rodrigo G; Lemos, Gustavo C; Baroni, Ronaldo H

    2016-09-01

    To determine the incremental diagnostic value of targeted biopsies added to an extended sextant biopsy scheme on a per-patient, risk-stratified basis in 2 academic centers using different multiparametric magnetic resonance imaging (MRI) protocols, a large group of radiologists, multiple biopsy systems, and different biopsy operators. All patients with suspected prostate cancer (PCa) who underwent multiparametric MRI of the prostate in 2 academic centers between February 2013 and January 2015 followed by systematic and targeted MRI-transrectal ultrasound fusion biopsy were reviewed. Risk-stratified detection rate using systematic biopsies was compared with targeted biopsies on a per-patient basis. The McNemar test was used to compare diagnostic performance of the 2 approaches. A total of 389 men met eligibility criteria. PCa was diagnosed in 47% (182/389), 52%(202/389), and 60%(235/389) of patients using the targeted, systematic, and combined (targeted plus systematic) approach, respectively. Compared with systematic biopsy, targeted biopsy diagnosed 11% (37 vs. 26) more intermediate-to-high risk (P<0.0001) and 16% (10 vs. 16) fewer low-risk tumors (P<0.0001). These results were replicated when data from each center, biopsy-naïve patients, and men with previous negative biopsies were analyzed separately. Targeted MRI-transrectal ultrasound fusion biopsy consistently improved the detection of clinically significant PCa in a large patient cohort with diverse equipment, protocols, radiologists, and biopsy operators as can be encountered in clinical practice. Copyright © 2016 Elsevier Inc. All rights reserved.

  5. Rectal biopsy

    MedlinePlus

    ... biopsy; Amyloidosis - rectal biopsy; Crohn disease - rectal biopsy; Colorectal cancer - biopsy; Hirschsprung disease - rectal biopsy ... abnormal conditions of the rectum, such as: Abscesses Colorectal ... Inflammation Tumors Amyloidosis Crohn disease Hirschsprung ...

  6. Transjugular liver biopsy with use of the shark jaw needle: diagnostic yield, complications, and cost-effectiveness.

    PubMed

    Psooy, B J; Clark, T W; Beecroft, J R; Malatjalian, D

    2001-01-01

    Obtaining transjugular liver biopsy specimens with use of single-use needle systems is expensive, whereas biopsy specimens obtained with use of reusable needle systems are frequently associated with inadequate core specimens. The authors report their experience with the reusable Cook Shark Jaw biopsy needle, including diagnostic yield, complications, and cost-effectiveness. A retrospective audit was performed of a cohort of 134 patients who underwent 136 transjugular liver biopsies with use of a reusable 16-gauge Shark Jaw needle during a 30-month period. Specimen adequacy and complication rates were assessed and direct costs of expendable components calculated. Cost-effectiveness was expressed as cost-per-successful biopsy. Biopsies were technically successful in 126 of 136 (93%) patients, with diagnostic histologic core specimens obtained in 124 of 126 (98%) patients, for an overall success rate of 91%. Complications included capsular penetration in six (4.4%) patients, cardiac arrhythmia in two (1.5%) patients, and puncture site hematoma or bleeding in 10 (7.4%) patients. Three tract embolizations were performed for capsular penetration. No instances of subcapsular hematoma, hemoperitoneum, or sepsis occurred, and no deaths were attributed to the procedure. The cost of expendable components totaled $103 per biopsy, corresponding to a cost-effectiveness of $113/successful biopsy. Transjugular liver biopsy specimens obtained with use of the Shark Jaw needle have a diagnostic yield comparable to those obtained with use of single-use biopsy systems, at a substantially lower cost with no increase in serious complications.

  7. Development of a 3D ultrasound-guided prostate biopsy system

    NASA Astrophysics Data System (ADS)

    Cool, Derek; Sherebrin, Shi; Izawa, Jonathan; Fenster, Aaron

    2007-03-01

    Biopsy of the prostate using ultrasound guidance is the clinical gold standard for diagnosis of prostate adenocarinoma. However, because early stage tumors are rarely visible under US, the procedure carries high false-negative rates and often patients require multiple biopsies before cancer is detected. To improve cancer detection, it is imperative that throughout the biopsy procedure, physicians know where they are within the prostate and where they have sampled during prior biopsies. The current biopsy procedure is limited to using only 2D ultrasound images to find and record target biopsy core sample sites. This information leaves ambiguity as the physician tries to interpret the 2D information and apply it to their 3D workspace. We have developed a 3D ultrasound-guided prostate biopsy system that provides 3D intra-biopsy information to physicians for needle guidance and biopsy location recording. The system is designed to conform to the workflow of the current prostate biopsy procedure, making it easier for clinical integration. In this paper, we describe the system design and validate its accuracy by performing an in vitro biopsy procedure on US/CT multi-modal patient-specific prostate phantoms. A clinical sextant biopsy was performed by a urologist on the phantoms and the 3D models of the prostates were generated with volume errors less than 4% and mean boundary errors of less than 1 mm. Using the 3D biopsy system, needles were guided to within 1.36 +/- 0.83 mm of 3D targets and the position of the biopsy sites were accurately localized to 1.06 +/- 0.89 mm for the two prostates.

  8. Bone Biopsy

    MedlinePlus

    ... News Physician Resources Professions Site Index A-Z Bone Biopsy Bone biopsy uses a needle and imaging ... the limitations of Bone Biopsy? What is a Bone Biopsy? A bone biopsy is an image-guided ...

  9. Cone biopsy

    MedlinePlus

    ... grade cone biopsy; High-grade cone biopsy; Carcinoma in situ-cone biopsy; CIS - cone biopsy; ASCUS - cone biopsy; ... marked dysplasia CIN III -- severe dysplasia to carcinoma in situ Abnormal results may also be due to cervical ...

  10. Prostate needle biopsy processing: a survey of laboratory practice across Europe.

    PubMed

    Varma, Murali; Berney, Daniel M; Algaba, Ferran; Camparo, Philippe; Compérat, Eva; Griffiths, David F R; Kristiansen, Glen; Lopez-Beltran, Antonio; Montironi, Rodolfo; Egevad, Lars

    2013-02-01

    To determine the degree of variation in the handling of prostate needle biopsies (PBNx) in laboratories across Europe. A web based survey was emailed to members of the European Network of Uropathology and the British Association of Urological Pathologists. Responses were received from 241 laboratories in 15 countries. PNBx were generally taken by urologists (93.8%) or radiologists (23.7%) but in 8.7% were also taken by non-medical personnel such as radiographers, nurses or biomedical assistants. Of the responding laboratories, 40.8% received cores in separate containers, 42.3% processed one core/block, 54.2% examined three levels/block, 49.4% examined one H&E section/level and 56.1% retained spare sections for potential immunohistochemistry. Of the laboratories, 40.9% retained unstained spares for over a year while 36.2% discarded spares within 1 month of reporting. Only two (0.8%) respondents routinely performed immunohistochemistry on all PNBx. There were differences in laboratory practice between the UK and the rest of Europe (RE). Procurement of PNBx by non-medical personnel was more common in the UK. RE laboratories more commonly received each core in a separate container, processed one core/block, examined fewer levels/block and examined more H&E sections/level. RE laboratories also retained spares for potential immunohistochemistry less often and for shorter periods. Use of p63 as the sole basal cell marker was more common in RE. There are marked differences in procurement, handling and processing of PNBx in laboratories across Europe. This data can help the development of best practice guidelines.

  11. Circulating tumor DNA: a promising biomarker in the liquid biopsy of cancer.

    PubMed

    Cheng, Feifei; Su, Li; Qian, Cheng

    2016-07-26

    Tissue biopsy is the standard diagnostic procedure for cancers and also provides a material for genotyping, which can assist in the targeted therapies of cancers. However, tissue biopsy-based cancer diagnostic procedures have limitations in their assessment of cancer development, prognosis and genotyping, due to tumor heterogeneity and evolution. Circulating tumor DNA (ctDNA) is single- or double-stranded DNA released by the tumor cells into the blood and it thus harbors the mutations of the original tumor. In recent years, liquid biopsy based on ctDNA analysis has shed a new light on the molecular diagnosis and monitoring of cancer. Studies found that the screening of genetic mutations using ctDNA is highly sensitive and specific, suggesting that ctDNA analysis may significantly improve current systems of tumor diagnosis, even facilitating early-stage detection. Moreover, ctDNA analysis is capable of accurately determining the tumor progression, prognosis and assisting in targeted therapy. Therefore, using ctDNA as a liquid biopsy may herald a revolution for tumor management. Herein, we review the biology of ctDNA, its detection methods and potential applications in tumor diagnosis, treatment and prognosis.

  12. Circulating tumor DNA: a promising biomarker in the liquid biopsy of cancer

    PubMed Central

    Cheng, Feifei; Su, Li; Qian, Cheng

    2016-01-01

    Tissue biopsy is the standard diagnostic procedure for cancers and also provides a material for genotyping, which can assist in the targeted therapies of cancers. However, tissue biopsy-based cancer diagnostic procedures have limitations in their assessment of cancer development, prognosis and genotyping, due to tumor heterogeneity and evolution. Circulating tumor DNA (ctDNA) is single- or double-stranded DNA released by the tumor cells into the blood and it thus harbors the mutations of the original tumor. In recent years, liquid biopsy based on ctDNA analysis has shed a new light on the molecular diagnosis and monitoring of cancer. Studies found that the screening of genetic mutations using ctDNA is highly sensitive and specific, suggesting that ctDNA analysis may significantly improve current systems of tumor diagnosis, even facilitating early-stage detection. Moreover, ctDNA analysis is capable of accurately determining the tumor progression, prognosis and assisting in targeted therapy. Therefore, using ctDNA as a liquid biopsy may herald a revolution for tumor management. Herein, we review the biology of ctDNA, its detection methods and potential applications in tumor diagnosis, treatment and prognosis. PMID:27223063

  13. Integrating machine learning and physician knowledge to improve the accuracy of breast biopsy.

    PubMed

    Dutra, I; Nassif, H; Page, D; Shavlik, J; Strigel, R M; Wu, Y; Elezaby, M E; Burnside, E

    2011-01-01

    In this work we show that combining physician rules and machine learned rules may improve the performance of a classifier that predicts whether a breast cancer is missed on percutaneous, image-guided breast core needle biopsy (subsequently referred to as "breast core biopsy"). Specifically, we show how advice in the form of logical rules, derived by a sub-specialty, i.e. fellowship trained breast radiologists (subsequently referred to as "our physicians") can guide the search in an inductive logic programming system, and improve the performance of a learned classifier. Our dataset of 890 consecutive benign breast core biopsy results along with corresponding mammographic findings contains 94 cases that were deemed non-definitive by a multidisciplinary panel of physicians, from which 15 were upgraded to malignant disease at surgery. Our goal is to predict upgrade prospectively and avoid surgery in women who do not have breast cancer. Our results, some of which trended toward significance, show evidence that inductive logic programming may produce better results for this task than traditional propositional algorithms with default parameters. Moreover, we show that adding knowledge from our physicians into the learning process may improve the performance of the learned classifier trained only on data.

  14. Method and apparatus for performing in-situ vacuum-assisted metal to glass sealing

    DOEpatents

    Kramer, D.P.; Massey, R.T.

    1985-07-18

    A method and apparatus for assembling and fusing glass to metal in a glass-metal electrical component is disclosed. The component includes a metallic shell formed with upper and lower cylindrical recesses connected together by longitudinal passages, a pair of metal rings and plural metal pins assembled to define electrical feed-throughs. The component parts are assembled on a fixture having a sleeve-like projection and a central mounting projection establishing concentric nesting surfaces to which the metal rings are slip-fitted in concentric alignment with each other spaced from sidewalls of the lower recess. The pins are in electrical contact with the metal rings. A glass pre-form is seated within the upper recess. The assembled structure is heated to a temperature sufficient to melt the glass pre-form which flows under gravity through the passages into the lower recess to provide an insulative seal between the metal parts. The gravity flow of glass is assisted by applying vacuum to the lower recess, ensuring that all spaces between the metal parts are filled with sealing glass without formation of bubbles.

  15. Method and apparatus for performing in-situ vacuum-assisted metal to glass sealing

    DOEpatents

    Kramer, Daniel P.; Massey, Richard T.

    1986-01-01

    A method and apparatus for assembling and fusing glass to metal in a glass-metal electrical component is disclosed. The component includes a metallic shell formed with upper and lower cylindrical recesses connected together by longitudinal passages, a pair of metal rings and plural metal pins assembled to define electrical feed-throughs. The component parts are assembled on a fixture having a sleeve-like projection and a central mounting projection establishing concentric nesting surfaces to which the metal rings are slip-fitted in concentric alignment with each other spaced from sidewalls of the lower recess. The pins are in electrical contact with the metal rings. A glass pre-form is seated within the upper recess. The assembled structure is heated to a temperature sufficient to melt the glass pre-form which flows under gravity through the passages into the lower recess to provide an insulative seal between the metal parts. The gravity flow of glass is assisted by applying vacuum to the lower recess, ensuring that all spaces between the metal parts are filled with sealing glass without formation of bubbles.

  16. Evaluation of cores from Jefferson Highway near Airline Highway : technical assistance report 16-03TA-C.

    DOT National Transportation Integrated Search

    2016-09-01

    This technical assistance report documents the investigation conducted by the Louisiana Transportation Research Center (LTRC) of the cored concrete from Westbound Jefferson Highway near Airline Highway in Baton Rouge, LA. The petrographic analysis sh...

  17. CT-Guided Transgluteal Biopsy for Systematic Random Sampling of the Prostate in Patients Without Rectal Access.

    PubMed

    Goenka, Ajit H; Remer, Erick M; Veniero, Joseph C; Thupili, Chakradhar R; Klein, Eric A

    2015-09-01

    The objective of our study was to review our experience with CT-guided transgluteal prostate biopsy in patients without rectal access. Twenty-one CT-guided transgluteal prostate biopsy procedures were performed in 16 men (mean age, 68 years; age range, 60-78 years) who were under conscious sedation. The mean prostate-specific antigen (PSA) value was 11.4 ng/mL (range, 2.3-39.4 ng/mL). Six had seven prior unsuccessful transperineal or transurethral biopsies. Biopsy results, complications, sedation time, and radiation dose were recorded. The mean PSA values and number of core specimens were compared between patients with malignant results and patients with nonmalignant results using the Student t test. The average procedural sedation time was 50.6 minutes (range, 15-90 minutes) (n = 20), and the mean effective radiation dose was 8.2 mSv (median, 6.6 mSv; range 3.6-19.3 mSv) (n = 13). Twenty of the 21 (95%) procedures were technically successful. The only complication was a single episode of gross hematuria and penile pain in one patient, which resolved spontaneously. Of 20 successful biopsies, 8 (40%) yielded adenocarcinoma (Gleason score: mean, 8; range, 7-9). Twelve biopsies yielded nonmalignant results (60%): high-grade prostatic intraepithelial neoplasia (n = 3) or benign prostatic tissue with or without inflammation (n = 9). Three patients had carcinoma diagnosed on subsequent biopsies (second biopsy, n = 2 patients; third biopsy, n = 1 patient). A malignant biopsy result was not significantly associated with the number of core specimens (p = 0.3) or the mean PSA value (p = 0.1). CT-guided transgluteal prostate biopsy is a safe and reliable technique for the systematic random sampling of the prostate in patients without a rectal access. In patients with initial negative biopsy results, repeat biopsy should be considered if there is a persistent rise in the PSA value.

  18. 3T MR-guided in-bore transperineal prostate biopsy: A comparison of robotic and manual needle-guidance templates.

    PubMed

    Tilak, Gaurie; Tuncali, Kemal; Song, Sang-Eun; Tokuda, Junichi; Olubiyi, Olutayo; Fennessy, Fiona; Fedorov, Andriy; Penzkofer, Tobias; Tempany, Clare; Hata, Nobuhiko

    2015-07-01

    To demonstrate the utility of a robotic needle-guidance template device as compared to a manual template for in-bore 3T transperineal magnetic resonance imaging (MRI)-guided prostate biopsy. This two-arm mixed retrospective-prospective study included 99 cases of targeted transperineal prostate biopsies. The biopsy needles were aimed at suspicious foci noted on multiparametric 3T MRI using manual template (historical control) as compared with a robotic template. The following data were obtained: the accuracy of average and closest needle placement to the focus, histologic yield, percentage of cancer volume in positive core samples, complication rate, and time to complete the procedure. In all, 56 cases were performed using the manual template and 43 cases were performed using the robotic template. The mean accuracy of the best needle placement attempt was higher in the robotic group (2.39 mm) than the manual group (3.71 mm, P < 0.027). The mean core procedure time was shorter in the robotic (90.82 min) than the manual group (100.63 min, P < 0.030). Percentage of cancer volume in positive core samples was higher in the robotic group (P < 0.001). Cancer yields and complication rates were not statistically different between the two subgroups (P = 0.557 and P = 0.172, respectively). The robotic needle-guidance template helps accurate placement of biopsy needles in MRI-guided core biopsy of prostate cancer. © 2014 Wiley Periodicals, Inc.

  19. Application of ionic liquids in vacuum microwave-assisted extraction followed by macroporous resin isolation of three flavonoids rutin, hyperoside and hesperidin from Sorbus tianschanica leaves.

    PubMed

    Gu, Huiyan; Chen, Fengli; Zhang, Qiang; Zang, Jing

    2016-03-01

    Rutin, hyperoside and hesperidin were effectively extracted from Sorbus tianschanica leaves by an ionic liquid vacuum microwave-assisted method. A series of ionic liquids with various anions and alkyl chain length of the cations were studied and the extraction was performed in [C6mim][BF4] aqueous solution. After optimization by a factorial design and response surface methodology, total extraction yield of 2.37mg/g with an error of 0.12mg/g (0.71±0.04mg/g, 1.18±0.06mg/g and 0.48±0.02 for rutin, hyperoside and hesperidin, respectively) was achieved under -0.08MPa for vacuum, 19min and 420W for microwave irradiation time and power, and 15mL/g for liquid-solid ratio. The proposed method here is more efficient and needs a shorter extraction time for rutin, hyperoside and hesperidin from S. tianschanica leaves than reference extraction techniques. In stability studies performed with standard rutin, hyperoside and hesperidin, the target analytes were stable under the optimum conditions. The proposed method had a high reproducibility and precision. In addition, separation of rutin, hyperoside and hesperidin from [C6mim][BF4] extraction solution was completed effectively by AB-8 macroporous resin adsorption and desorption process. Ionic liquid vacuum microwave-assisted extraction is a simple, rapid and efficient sample extraction technique. Copyright © 2016 Elsevier B.V. All rights reserved.

  20. A Single-Institution Experience in Percutaneous Image-Guided Biopsy of Malignant Pleural Mesothelioma

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Welch, B. T., E-mail: Welch.brian@mayo.edu; Eiken, P. W.; Atwell, T. D.

    PurposeMesothelioma has been considered a difficult pathologic diagnosis to achieve via image-guided core needle biopsy. The purpose of this study was to assess the diagnostic sensitivity of percutaneous image-guided biopsy for diagnosis of pleural mesothelioma.Materials and MethodsRetrospective review was performed to identify patients with a confirmed diagnosis of pleural mesothelioma and who underwent image-guided needle biopsy between January 1, 2002, and January 1, 2016. Thirty-two patients with pleural mesothelioma were identified and included for analysis in 33 image-guided biopsy procedures. Patient, procedural, and pathologic characteristics were recorded. Complications were characterized via standardized nomenclature [Common Terminology for Clinically Adverse Events (CTCAE)].ResultsPercutaneousmore » image-guided biopsy was associated with an overall sensitivity of 81%. No CTCAE clinically significant complications were observed. No image-guided procedures were complicated by pneumothorax or necessitated chest tube placement. No patients had tumor seeding of the biopsy tract.ConclusionPercutaneous image-guided biopsy can achieve high sensitivity for pathologic diagnosis of pleural mesothelioma with a low procedural complication rate, potentially obviating need for surgical biopsy.« less

  1. Detection of prostate cancer using magnetic resonance imaging/ultrasonography image-fusion targeted biopsy in African-American men.

    PubMed

    Shin, Toshitaka; Smyth, Thomas B; Ukimura, Osamu; Ahmadi, Nariman; de Castro Abreu, Andre Luis; Oishi, Masakatsu; Mimata, Hiromitsu; Gill, Inderbir S

    2017-08-01

    To assess the diagnostic yield of targeted prostate biopsy in African-American (A-A) men using image fusion of multi-parametric magnetic resonance imaging (mpMRI) with real-time transrectal ultrasonography (US). We retrospectively analysed 661 patients (117 A-A and 544 Caucasian) who had mpMRI before biopsy and then underwent MRI/US image-fusion targeted biopsy (FTB) between October 2012 and August 2015. The mpMRIs were reported on a 5-point Likert scale of suspicion. Clinically significant prostate cancer (CSPC) was defined as biopsy Gleason score ≥7. After controlling for age, prostate-specific antigen level and prostate volume, there were no significant differences between A-A and Caucasian men in the detection rate of overall cancer (35.0% vs 34.2%, P = 0.9) and CSPC (18.8% vs 21.7%, P = 0.3) with MRI/US FTB. There were no significant differences between the races in the location of dominant lesions on mpMRI, and in the proportion of 5-point Likert scoring. In A-A men, MRI/US FTB from the grade 4-5 lesions outperformed random biopsy in the detection rate of overall cancer (70.6% vs 37.2%, P = 0.003) and CSPC (52.9% vs 12.4%, P < 0.001). MRI/US FTB outperformed random biopsy in cancer core length (5.0 vs 2.4 mm, P = 0.001), in cancer rate per core (24.9% vs 6.8%, P < 0.001), and in efficiency for detecting one patient with CSPC (mean number of cores needed 13.3 vs 81.9, P < 0.001), respectively. Our key finding confirms a lack of racial difference in the detection rate of overall prostate cancers and CSPC with MRI/US FTB between A-A and Caucasian men. MRI/US FTB detected more CSPC using fewer cores compared with random biopsy. © 2017 The Authors BJU International © 2017 BJU International Published by John Wiley & Sons Ltd.

  2. Kidney Biopsy

    MedlinePlus

    ... Series Urinary Tract Imaging Urodynamic Testing Virtual Colonoscopy Kidney Biopsy What is a kidney biopsy? A kidney biopsy is a procedure that ... performs procedures using imaging equipment Why is a kidney biopsy performed? A health care provider will perform ...

  3. Transperineal prostate biopsy under magnetic resonance image guidance: a needle placement accuracy study.

    PubMed

    Blumenfeld, Philip; Hata, Nobuhiko; DiMaio, Simon; Zou, Kelly; Haker, Steven; Fichtinger, Gabor; Tempany, Clare M C

    2007-09-01

    To quantify needle placement accuracy of magnetic resonance image (MRI)-guided core needle biopsy of the prostate. A total of 10 biopsies were performed with 18-gauge (G) core biopsy needle via a percutaneous transperineal approach. Needle placement error was assessed by comparing the coordinates of preplanned targets with the needle tip measured from the intraprocedural coherent gradient echo images. The source of these errors was subsequently investigated by measuring displacement caused by needle deflection and needle susceptibility artifact shift in controlled phantom studies. Needle placement error due to misalignment of the needle template guide was also evaluated. The mean and standard deviation (SD) of errors in targeted biopsies was 6.5 +/- 3.5 mm. Phantom experiments showed significant placement error due to needle deflection with a needle with an asymmetrically beveled tip (3.2-8.7 mm depending on tissue type) but significantly smaller error with a symmetrical bevel (0.6-1.1 mm). Needle susceptibility artifacts observed a shift of 1.6 +/- 0.4 mm from the true needle axis. Misalignment of the needle template guide contributed an error of 1.5 +/- 0.3 mm. Needle placement error was clinically significant in MRI-guided biopsy for diagnosis of prostate cancer. Needle placement error due to needle deflection was the most significant cause of error, especially for needles with an asymmetrical bevel. (c) 2007 Wiley-Liss, Inc.

  4. 20 CFR 641.730 - How will the Department assist grantees in the transition to the new core performance indicators?

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 20 Employees' Benefits 3 2010-04-01 2010-04-01 false How will the Department assist grantees in the transition to the new core performance indicators? 641.730 Section 641.730 Employees' Benefits... transition to the new core performance indicators? (a) General transition provision. As soon as practicable...

  5. Combination of prostate imaging reporting and data system (PI-RADS) score and prostate-specific antigen (PSA) density predicts biopsy outcome in prostate biopsy naïve patients.

    PubMed

    Washino, Satoshi; Okochi, Tomohisa; Saito, Kimitoshi; Konishi, Tsuzumi; Hirai, Masaru; Kobayashi, Yutaka; Miyagawa, Tomoaki

    2017-02-01

    To assess the value of the Prostate Imaging Reporting and Data System (PI-RADS) scoring system, for prostate multi-parametric magnetic resonance imaging (mpMRI) to detect prostate cancer, and classical parameters, such as prostate-specific antigen (PSA) level, prostate volume and PSA density, for predicting biopsy outcome in biopsy naïve patients who have suspected prostate cancer. Patients who underwent mpMRI at our hospital, and who had their first prostate biopsy between July 2010 and April 2014, were analysed retrospectively. The prostate biopsies were taken transperineally under transrectal ultrasonography guidance. In all, 14 cores were biopsied as a systematic biopsy in all patients. Two cognitive fusion-targeted biopsy cores were added for each lesion in patients who had suspicious or equivocal lesions on mpMRI. The PI-RADS scoring system version 2.0 (PI-RADS v2) was used to describe the MRI findings. Univariate and multivariate analyses were performed to determine significant predictors of prostate cancer and clinically significant prostate cancer. In all, 288 patients were analysed. The median patient age, PSA level, prostate volume and PSA density were 69 years, 7.5 ng/mL, 28.7 mL, and 0.26 ng/mL/mL, respectively. The biopsy results were benign, clinically insignificant, and clinically significant prostate cancer in 129 (45%), 18 (6%) and 141 (49%) patients, respectively. The multivariate analysis revealed that PI-RADS v2 score and PSA density were independent predictors for prostate cancer and clinically significant prostate cancer. When PI-RADS v2 score and PSA density were combined, a PI-RADS v2 score of ≥4 and PSA density ≥0.15 ng/mL/mL, or PI-RADS v2 score of 3 and PSA density of ≥0.30 ng/mL/mL, was associated with the highest clinically significant prostate cancer detection rates (76-97%) on the first biopsy. Of the patients in this group with negative biopsy results, 22% were subsequently diagnosed as prostate cancer. In contrast, a PI

  6. Analysis of Clinical and Pathologic Factors of Pure, Flat Epithelial Atypia on Core Needle Biopsy to Aid in the Decision of Excision or Observation

    PubMed Central

    Berry, John S; Trappey, Alfred F; Vreeland, Timothy J; Pattyn, Adam R; Clifton, Guy T; Berry, Elizabeth A; Schneble, Erika J; Kirkpatrick, Aaron D; Saenger, Jeffrey S; Peoples, George E

    2016-01-01

    Background: The optimal treatment of flat epithelial atypia (FEA) found on breast core needle biopsy (CNB) is controversial. We performed a retrospective review of our institutional experience with FEA to determine if excisional biopsy may be deferred. Methods: Surgical records from 2009 to 2012 were reviewed for FEA diagnosis. After exclusion for concomitant lesions, CNBs of pure FEA were classified using a previously agreed upon descriptor of “focal” versus “prominent”. Data was analyzed with the Fisher's Exact and Student-t test as appropriate. Results: Of 71 CNBs evaluated, pure FEA was identified on 27 CNBs. Final excisional biopsy was benign in 24 of 27 cases (88%) with associated ductal carcinoma in-situ (DCIS) in 3 of 27 cases (11%). Eighteen of 27 (67%) CNBs were classified as focal while 9 (33%) were described as prominent. Zero of the 18 focal patients had a malignancy compared to 3 of the 9 in the prominent group (0% vs 33%, p=0.02). Of the 27 pure FEA CNBs, 6 patients had a personal history of breast carcinoma, five DCIS and one invasive ductal carcinoma. No malignancies were found in the 21 patients without a personal history of breast carcinoma versus three in the patients with a positive history (0/21 v 3/6, p=0.007). Conclusions: Our data suggests those women who have adequate sampling and sectioning of CNBs, with focal, pure FEA on pathology, and are without a personal history of breast cancer may undergo a period of imaging surveillance. Conversely, patients with a history of breast cancer or pure, prominent FEA on CNB disease should proceed to excisional biopsy. PMID:26722353

  7. Analysis of Clinical and Pathologic Factors of Pure, Flat Epithelial Atypia on Core Needle Biopsy to Aid in the Decision of Excision or Observation.

    PubMed

    Berry, John S; Trappey, Alfred F; Vreeland, Timothy J; Pattyn, Adam R; Clifton, Guy T; Berry, Elizabeth A; Schneble, Erika J; Kirkpatrick, Aaron D; Saenger, Jeffrey S; Peoples, George E

    2016-01-01

    The optimal treatment of flat epithelial atypia (FEA) found on breast core needle biopsy (CNB) is controversial. We performed a retrospective review of our institutional experience with FEA to determine if excisional biopsy may be deferred. Surgical records from 2009 to 2012 were reviewed for FEA diagnosis. After exclusion for concomitant lesions, CNBs of pure FEA were classified using a previously agreed upon descriptor of "focal" versus "prominent". Data was analyzed with the Fisher's Exact and Student-t test as appropriate. Of 71 CNBs evaluated, pure FEA was identified on 27 CNBs. Final excisional biopsy was benign in 24 of 27 cases (88%) with associated ductal carcinoma in-situ (DCIS) in 3 of 27 cases (11%). Eighteen of 27 (67%) CNBs were classified as focal while 9 (33%) were described as prominent. Zero of the 18 focal patients had a malignancy compared to 3 of the 9 in the prominent group (0% vs 33%, p=0.02). Of the 27 pure FEA CNBs, 6 patients had a personal history of breast carcinoma, five DCIS and one invasive ductal carcinoma. No malignancies were found in the 21 patients without a personal history of breast carcinoma versus three in the patients with a positive history (0/21 v 3/6, p=0.007). Our data suggests those women who have adequate sampling and sectioning of CNBs, with focal, pure FEA on pathology, and are without a personal history of breast cancer may undergo a period of imaging surveillance. Conversely, patients with a history of breast cancer or pure, prominent FEA on CNB disease should proceed to excisional biopsy.

  8. A Single Center Evaluation of the Diagnostic Accuracy of Multiparametric Magnetic Resonance Imaging against Transperineal Prostate Mapping Biopsy: An Analysis of Men with Benign Histology and Insignificant Cancer following Transrectal Ultrasound Biopsy.

    PubMed

    Pal, Raj P; Ahmad, Ros; Trecartan, Shaun; Voss, James; Ahmed, Shaista; Bazo, Alvaro; Lloyd, Jon; Walton, Thomas J

    2018-03-01

    In this study we evaluated the diagnostic performance of transrectal ultrasound guided biopsy and multiparametric magnetic resonance imaging to detect prostate cancer against transperineal prostate mapping biopsy as the reference test. Transrectal ultrasound guided biopsy, multiparametric magnetic resonance imaging and transperineal prostate mapping biopsy were performed in 426 patients between April 2012 and January 2016. Patients initially underwent systematic 12 core transrectal ultrasound guided biopsy followed 3 months later by 1.5 Tesla, high resolution T2, diffusion-weighted, dynamic contrast enhanced multiparametric magnetic resonance imaging. Two specialist uroradiologists blinded to the results of transperineal prostate mapping biopsy allocated a PI-RADS™ (Prostate Imaging-Reporting and Data System) score to each multiparametric magnetic resonance imaging study. Transperineal prostate mapping biopsy with 5 mm interval sampling, which was performed within 6 months of multiparametric magnetic resonance imaging, served as the reference test. Transrectal ultrasound guided biopsy identified 247 of 426 patients with prostate cancer and 179 of 426 with benign histology. Transperineal prostate mapping biopsy detected prostate cancer in 321 of 426 patients. On transperineal prostate mapping biopsy 94 of 179 patients with benign transrectal ultrasound guided biopsy had prostate cancer and 95 of 247 with prostate cancer on transrectal ultrasound guided biopsy were identified with cancer of higher grade. Using a multiparametric magnetic resonance imaging PI-RADS score of 3 or greater to detect significant prostate cancer, defined as any core containing Gleason 4 + 3 or greater prostate cancer on transperineal prostate mapping biopsy, the ROC AUC was 0.754 (95% CI 0.677-0.819) with 87.0% sensitivity (95% CI 77.3-97.0), 55.3% specificity (95% CI 50.2-60.4) and 97.1% negative predictive value (95% CI 94.8-99.4). Multiparametric magnetic resonance imaging is a more

  9. PI-RADS version 2 for prediction of pathological downgrading after radical prostatectomy: a preliminary study in patients with biopsy-proven Gleason Score 7 (3+4) prostate cancer.

    PubMed

    Woo, Sungmin; Kim, Sang Youn; Lee, Joongyub; Kim, Seung Hyup; Cho, Jeong Yeon

    2016-10-01

    To evaluate PI-RADSv2 for predicting pathological downgrading after radical prostatectomy (RP) in patients with biopsy-proven Gleason score (GS) 7(3+4) PC. A total of 105 patients with biopsy-proven GS 7(3+4) PC who underwent multiparametric prostate MRI followed by RP were included. Two radiologists assigned PI-RADSv2 scores for each patient. Preoperative clinicopathological variables and PI-RADSv2 scores were compared between patients with and without downgrading after RP using the Wilcoxon rank sum test or Fisher's exact test. Logistic regression analyses with Firth's bias correction were performed to assess their association with downgrading. Pathological downgrading was identified in ten (9.5 %) patients. Prostate-specific antigen (PSA), PSA density, percentage of cores with GS 7(3+4), and greatest percentage of core length (GPCL) with GS 7(3+4) were significantly lower in patients with downgrading (p = 0.002-0.037). There was no significant difference in age and clinical stage (p = 0.537-0.755). PI-RADSv2 scores were significantly lower in patients with downgrading (3.8 versus 4.4, p = 0.012). At univariate logistic regression analysis, PSA, PSA density, and PI-RADSv2 scores were significant predictors of downgrading (p = 0.003-0.022). Multivariate analysis revealed only PSA density and PI-RADSv2 scores as independent predictors of downgrading (p = 0.014-0.042). The PI-RADSv2 scoring system was an independent predictor of pathological downgrading after RP in patients with biopsy-proven GS 7(3+4) PC. • PI-RADSv2 was an independent predictor of downgrading in biopsy-proven GS 7(3+4) PC • PSA density was also an independent predictor of downgrading • MRI may assist in identifying AS candidates in biopsy-proven GS 7(3+4) PC patients.

  10. The Percent of Positive Biopsy Cores Improves Prediction of Prostate Cancer-Specific Death in Patients Treated With Dose-Escalated Radiotherapy

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Qian Yushen; Feng, Felix Y.; Veterans Administration Medical Center, Ann Arbor, MI

    2011-11-01

    Purpose: To examine the prognostic utility of the percentage of positive cores (PPC) at the time of prostate biopsy for patients treated with dose-escalated external beam radiation therapy. Methods and Materials: We performed a retrospective analysis of patients treated at University of Michigan Medical Center to at least 75 Gy. Patients were stratified according to PPC by quartile, and freedom from biochemical failure (nadir + 2 ng/mL), freedom from metastasis (FFM), cause-specific survival (CSS), and overall survival (OS) were assessed by log-rank test. Receiver operator characteristic (ROC) curve analysis was used to determine the optimal cut point for PPC stratification.more » Finally, Cox proportional hazards multivariate regression was used to assess the impact of PPC on clinical outcome when adjusting for National Comprehensive Cancer Network (NCCN) risk group and androgen deprivation therapy. Results: PPC information was available for 651 patients. Increasing-risk features including T stage, prostate-specific antigen, Gleason score, and NCCN risk group were all directly correlated with increasing PPC. On log-rank evaluation, all clinical endpoints, except for OS, were associated with PPC by quartile, with worse clinical outcomes as PPC increased, with the greatest impact seen in the highest quartile (>66.7% of cores positive). ROC curve analysis confirmed that a cut point using two-thirds positive cores was most closely associated with CSS (p = 0.002; area under ROC curve, 0.71). On univariate analysis, stratifying patients according to PPC less than or equal to 66.7% vs. PPC greater than 66.7% was prognostic for freedom from biochemical failure (p = 0.0001), FFM (p = 0.0002), and CSS (p = 0.0003) and marginally prognostic for OS (p = 0.055). On multivariate analysis, after adjustment for NCCN risk group and androgen deprivation therapy use, PPC greater than 66.7% increased the risk for biochemical failure (p = 0.0001; hazard ratio [HR], 2.1 [95

  11. Electrostatically assisted fabrication of silver-dielectric core/shell nanoparticles thin film capacitor with uniform metal nanoparticle distribution and controlled spacing.

    PubMed

    Li, Xue; Niitsoo, Olivia; Couzis, Alexander

    2016-03-01

    An electrostatically-assisted strategy for fabrication of thin film composite capacitors with controllable dielectric constant (k) has been developed. The capacitor is composed of metal-dielectric core/shell nanoparticle (silver/silica, Ag@SiO2) multilayer films, and a backfilling polymer. Compared with the simple metal particle-polymer mixtures where the metal nanoparticles (NP) are randomly dispersed in the polymer matrix, the metal volume fraction in our capacitor was significantly increased, owing to the densely packed NP multilayers formed by the electrostatically assisted assembly process. Moreover, the insulating layer of silica shell provides a potential barrier that reduces the tunneling current between neighboring Ag cores, endowing the core/shell nanocomposites with a stable and relatively high dielectric constant (k) and low dielectric loss (D). Our work also shows that the thickness of the SiO2 shell plays a dominant role in controlling the dielectric properties of the nanocomposites. Control over metal NP separation distance was realized not only by variation the shell thickness of the core/shell NPs but also by introducing a high k nanoparticle, barium strontium titanate (BST) of relatively smaller size (∼8nm) compared to 80-160nm of the core/shell Ag@SiO2 NPs. The BST assemble between the Ag@SiO2 and fill the void space between the closely packed core/shell NPs leading to significant enhancement of the dielectric constant. This electrostatically assisted assembly method is promising for generating multilayer films of a large variety of NPs over large areas at low cost. Copyright © 2015 Elsevier Inc. All rights reserved.

  12. Is seminal vesiculectomy necessary in all patients with biopsy Gleason score 6?

    PubMed

    Gofrit, Ofer N; Zorn, Kevin C; Shikanov, Sergey A; Zagaja, Gregory P; Shalhav, Arieh L

    2009-04-01

    Radiotherapists are excluding the seminal vesicles (SVs) from their target volume in cases of low-risk prostate cancer. However, these glands are routinely removed in every radical prostatectomy. Dissection of the SVs can damage the pelvic plexus, compromise trigonal, bladder neck, and cavernosal innervation, and contribute to delayed gain of continence and erectile function. In this study we evaluated the oncological benefit of routine removal of the SVs in currently operated patients. A total of 1003 patients (mean age, 59.7 years) with prostate cancer underwent robot-assisted radical prostatectomy between February 2003 and July 2007. Seminal vesicle invasion (SVI) was found in 46 of the operated patients (4.6%). Biopsy Gleason score (BGS), preoperative serum PSA, clinical tumor stage, percent of positive cores, and maximal percentage of cancer in a core had all a significant impact on the risk of SVI. Only 4/634 patients (0.6%) with BGS < or =6 suffered from SVI, as opposed to 42/369 (11.4%) with higher Gleason scores. Seminal vesiculectomy does not benefit more than 99% of the patients with BGS < or =6. Considering the potential neural and vascular damage associated with seminal vesiculectomy, we suggest that routine removal of these glands during radical prostatectomy in these cases is not necessary.

  13. Skin lesion biopsy

    MedlinePlus

    ... biopsy - skin; Skin cancer - biopsy; Melanoma - biopsy; Squamous cell cancer - biopsy; Basal cell cancer - biopsy; Mohs microsurgery ... dermatitis Infection from bacteria or fungus Melanoma Basal cell skin cancer Squamous cell skin cancer

  14. Does imprint cytology improve the accuracy of transrectal prostate needle biopsy?

    PubMed

    Sayar, Hamide; Bulut, Burak Besir; Bahar, Abdulkadir Yasir; Bahar, Mustafa Remzi; Seringec, Nurten; Resim, Sefa; Çıralık, Harun

    2015-02-01

    To evaluate the accuracy of imprint cytology of core needle biopsy specimens in the diagnosis of prostate cancer. Between December 24, 2011 and May 9, 2013, patients with an abnormal DRE and/or serum PSA level of >2.5 ng/mL underwent transrectal prostate needle biopsy. Samples with positive imprint cytology but negative initial histologic exam underwent repeat sectioning and histological examination. 1,262 transrectal prostate needle biopsy specimens were evaluated from 100 patients. Malignant imprint cytology was found in 236 specimens (18.7%), 197 (15.6%) of which were confirmed by histologic examination, giving an initial 3.1% (n = 39) rate of discrepant results by imprint cytology. Upon repeat sectioning and histologic examination of these 39 biopsy samples, 14 (1.1% of the original specimens) were then diagnosed as malignant, 3 (0.2%) as atypical small acinar proliferation (ASAP), and 5 (0.4%) as high-grade prostatic intraepithelial neoplasia (HGPIN). Overall, 964 (76.4%) specimens were negative for malignancy by imprint cytology. Seven (0.6%) specimens were benign by cytology but malignant cells were found on histological evaluation. On imprint cytology examination, nonmalignant but abnormal findings were seen in 62 specimens (4.9%). These were all due to benign processes. After reexamination, the accuracy, sensitivity, specificity, positive predictive value, negative predictive value, false-positive rate, false-negative rate of imprint preparations were 98.1, 96.9, 98.4, 92.8, 99.3, 1.6, 3.1%, respectively. Imprint cytology is valuable tool for evaluating TRUS-guided core needle biopsy specimens from the prostate. Use of imprint cytology in combination with histopathology increases diagnostic accuracy when compared with histopathologic assessment alone. © 2014 Wiley Periodicals, Inc.

  15. Trans-rectal interventional MRI: initial prostate biopsy experience

    NASA Astrophysics Data System (ADS)

    Greenwood, Bernadette M.; Behluli, Meliha R.; Feller, John F.; May, Stuart T.; Princenthal, Robert; Winkel, Alex; Kaminsky, David B.

    2010-02-01

    Dynamic contrast-enhanced (DCE) magnetic resonance imaging (MRI) of the prostate gland when evaluated along with T2-weighted images, diffusion-weighted images (DWI) and their corresponding apparent diffusion coefficient (ADC) maps can yield valuable information in patients with rising or elevated serum prostate-specific antigen (PSA) levels1. In some cases, patients present with multiple negative trans-rectal ultrasound (TRUS) biopsies, often placing the patient into a cycle of active surveillance. Recently, more patients are undergoing TRIM for targeted biopsy of suspicious findings with a cancer yield of ~59% compared to 15% for second TRUS biopsy2 to solve this diagnostic dilemma and plan treatment. Patients were imaged in two separate sessions on a 1.5T magnet using a cardiac phased array parallel imaging coil. Automated CAD software was used to identify areas of wash-out. If a suspicious finding was identified on all sequences it was followed by a second imaging session. Under MRI-guidance, cores were acquired from each target region3. In one case the microscopic diagnosis was prostatic intraepithelial neoplasia (PIN), in the other it was invasive adenocarcinoma. Patient 1 had two negative TRUS biopsies and a PSA level of 9ng/mL. Patient 2 had a PSA of 7.2ng/mL. He underwent TRUS biopsy which was negative for malignancy. He was able to go on to treatment for his prostate carcinoma (PCa)4. MRI may have an important role in a subset of patients with multiple negative TRUS biopsies and elevated or rising PSA.

  16. Yield of Routine Image-Guided Biopsy of Renal Mass Thermal Ablation Zones: 11-Year Experience.

    PubMed

    Wasnik, Ashish P; Higgins, Ellen J; Fox, Giovanna A; Caoili, Elaine M; Davenport, Matthew S

    2018-06-19

    To determine the yield of routine image-guided core biopsy of renal cell carcinoma (RCC) thermal ablation zones. Institutional review board approval was obtained for this Health Insurance Portability and Accountability Act-compliant quality improvement effort. Routine core biopsy of RCC ablation zones was performed 2 months postablation from July 2003 to December 2014. Routine nicotinamide adenine dinucleotide staining was performed by specialized genitourinary pathologists to assess cell viability. The original purpose of performing routine postablation biopsy was to verify, in addition to imaging, whether the mass was completely treated. Imaging was stratified as negative, indeterminate, or positive for viable malignancy. Histology was stratified as negative, indeterminate, positive, or nondiagnostic for viable malignancy. Histology results were compared to prebiopsy imaging findings. Routine ablation zone biopsy was performed after 50% (146/292) of index ablations (24 cryoablations, 122 radiofrequency ablations), and postablation imaging was performed more often with multiphasic computed tomography than magnetic resonance imaging (100 vs 46, p < 0.0001). When imaging was negative (n = 117), biopsy added no additional information (92% [n = 108] negative, 0.9% [n = 1] indeterminate, 7% [n = 8] nondiagnostic). When imaging was indeterminate (n = 19), 11% (n = 2) of biopsies had viable RCC and 89% (n = 17) were negative. When imaging was positive, biopsy detected viable neoplasm in only 10% (1/10) of cases; 80% (8/10) were negative and 10% (1/10) were nondiagnostic. Routine biopsy of renal ablation zones to validate postablation imaging results was not value-added and therefore was discontinued at the study institution. Copyright © 2018. Published by Elsevier Inc.

  17. Stabilization of lunar core samples

    NASA Technical Reports Server (NTRS)

    Nagle, J. S.; Duke, M. B.

    1974-01-01

    Processing of lunar cores includes: (1) careful dissection for study of loose fines, and (2) stabilization of the residue by peeling and impregnation. The newly developed technique for preparing thin peels of lunar cores requires application of the methacrylate adhesive to a backing strip, before taking the peel. To ensure complete impregnation of the very fine, dry lunar soil, the low-viscosity epoxy, Araldite 506, is gently flowed onto the core, under vacuum.

  18. Overall Quality of Fruits and Vegetables Products Affected by the Drying Processes with the Assistance of Vacuum-Microwaves.

    PubMed

    Figiel, Adam; Michalska, Anna

    2016-12-30

    The seasonality of fruits and vegetables makes it impossible to consume and use them throughout the year, thus numerous processing efforts have been made to offer an alternative to their fresh consumption and application. To prolong their availability on the market, drying has received special attention as currently this method is considered one of the most common ways for obtaining food and pharmaceutical products from natural sources. This paper demonstrates the weakness of common drying methods applied for fruits and vegetables and the possible ways to improve the quality using different drying techniques or their combination with an emphasis on the microwave energy. Particular attention has been drawn to the combined drying with the assistance of vacuum-microwaves. The quality of the dried products was ascribed by chemical properties including the content of polyphenols, antioxidant capacity and volatiles as well as physical parameters such as color, shrinkage, porosity and texture. Both these fields of quality classification were considered taking into account sensory attributes and energy aspects in the perspective of possible industrial applications. In conclusion, the most promising way for improving the quality of dried fruit and vegetable products is hybrid drying consisting of osmotic dehydration in concentrated fruit juices followed by heat pump drying and vacuum-microwave finish drying.

  19. Overall Quality of Fruits and Vegetables Products Affected by the Drying Processes with the Assistance of Vacuum-Microwaves

    PubMed Central

    Figiel, Adam; Michalska, Anna

    2016-01-01

    The seasonality of fruits and vegetables makes it impossible to consume and use them throughout the year, thus numerous processing efforts have been made to offer an alternative to their fresh consumption and application. To prolong their availability on the market, drying has received special attention as currently this method is considered one of the most common ways for obtaining food and pharmaceutical products from natural sources. This paper demonstrates the weakness of common drying methods applied for fruits and vegetables and the possible ways to improve the quality using different drying techniques or their combination with an emphasis on the microwave energy. Particular attention has been drawn to the combined drying with the assistance of vacuum-microwaves. The quality of the dried products was ascribed by chemical properties including the content of polyphenols, antioxidant capacity and volatiles as well as physical parameters such as color, shrinkage, porosity and texture. Both these fields of quality classification were considered taking into account sensory attributes and energy aspects in the perspective of possible industrial applications. In conclusion, the most promising way for improving the quality of dried fruit and vegetable products is hybrid drying consisting of osmotic dehydration in concentrated fruit juices followed by heat pump drying and vacuum-microwave finish drying. PMID:28042845

  20. Evolution of prostate biopsy techniques. Looking back on a meaningful journey.

    PubMed

    Sivaraman, A; Sanchez-Salas, R; Castro-Marin, M; Barret, E; Guillot-Tantay, C; Prapotnich, D; Cathelineau, X

    2016-10-01

    The technique of prostate biopsy has evolved a long way since its inception to being a safe diagnostic procedure. The principles of the biopsy technique continue to improvise with the knowledge about prostate cancer and availability of newer treatment options like active surveillance and focal therapy. Currently, we depend on accurate cancer information from the biopsy more than ever for deciding the ideal treatment option. The aim of this review is to present the major milestones in prostate biopsy technique evolutions and its impact on the prostate cancer management. We performed a detailed non-systematic literature review to present the historical facts on the transformations in prostate biopsy techniques and also the direction of present research to improve accurate cancer detection. There is a clear change in trend in biopsy technique before and after the introduction of transrectal ultrasound and prostate specific antigen. In the earlier era, the biopsies were aimed at palpable nodules and obtaining adequate prostatic tissue for diagnosis while the later era has moved towards detection of non-palpable and early prostate cancer. Recently, there is an increasing trend towards image guided targeted biopsies to extract maximum cancer information from minimum biopsy cores. Prostate biopsy techniques have seen major changes since its inception and have a major impact on prostate cancer management. There is a great potential for research which can further support the newer treatment options like focal therapy. Copyright © 2016 AEU. Publicado por Elsevier España, S.L.U. All rights reserved.

  1. How to Interpret Thyroid Biopsy Results: A Three-Year Retrospective Interventional Radiology Experience

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Oppenheimer, Jason D., E-mail: j-oppenheimer@md.northwestern.edu; Kasuganti, Deepa; Nayar, Ritu

    2010-08-15

    Results of thyroid biopsy determine whether thyroid nodule resection is appropriate and the extent of thyroid surgery. At our institution we use 20/22-gauge core biopsy (CBx) in conjunction with fine-needle aspiration (FNA) to decrease the number of passes and improve adequacy. Occasionally, both ultrasound (US)-guided FNA and CBx yield unsatisfactory specimens. To justify clinical recommendations for these unsatisfactory thyroid biopsies, we compare rates of malignancy at surgical resection for unsatisfactory biopsy results against definitive biopsy results. We retrospectively reviewed a database of 1979 patients who had a total of 2677 FNA and 663 CBx performed by experienced interventional radiologists undermore » US guidance from 2003 to 2006 at a tertiary-care academic center. In 451 patients who had surgery following biopsy, Fisher's exact test was used to compare surgical malignancy rates between unsatisfactory and malignant biopsy cohorts as well as between unsatisfactory and benign biopsy cohorts. We defined statistical significance at P = 0.05. We reported an overall unsatisfactory thyroid biopsy rate of 3.7% (100/2677). A statistically significant higher rate of surgically proven malignancies was found in malignant biopsy patients compared to unsatisfactory biopsy patients (P = 0.0001). The incidence of surgically proven malignancy in unsatisfactory biopsy patients was not significantly different from that in benign biopsy patients (P = 0.8625). In conclusion, an extremely low incidence of malignancy was associated with both benign and unsatisfactory thyroid biopsy results. The difference in incidence between these two groups was not statistically significant. Therefore, patients with unsatisfactory biopsy specimens can be reassured and counseled accordingly.« less

  2. In-fiber refractive index sensor based on single eccentric hole-assisted dual-core fiber.

    PubMed

    Yang, Jing; Guan, Chunying; Tian, Peixuan; Yuan, Tingting; Zhu, Zheng; Li, Ping; Shi, Jinhui; Yang, Jun; Yuan, Libo

    2017-11-01

    We propose a novel and simple in-fiber refractive index sensor based on resonant coupling, constructed by a short section of single eccentric hole-assisted dual-core fiber (SEHADCF) spliced between two single-mode fibers. The coupling characteristics of the SEHADCF are calculated numerically. The strong resonant coupling occurs when the fundamental mode of the center core phase-matches to that of the suspended core in the air hole. The effective refractive index of the fundamental mode of the suspended core can be obviously changed by injecting solution into the air hole. The responses of the proposed devices to the refractive index and temperature are experimentally measured. The refractive index sensitivity is 627.5 nm/refractive index unit in the refractive index range of 1.335-1.385. The sensor without solution filling is insensitive to temperature in the range of 30-90°C. The proposed refractive index sensor has outstanding advantages, such as simple fabrication, good mechanical strength, and excellent microfluidic channel, and will be of importance in biological detection, chemical analysis, and environment monitoring.

  3. Small renal mass biopsy--how, what and when: report from an international consensus panel.

    PubMed

    Tsivian, Matvey; Rampersaud, Edward N; del Pilar Laguna Pes, Maria; Joniau, Steven; Leveillee, Raymond J; Shingleton, William B; Aron, Monish; Kim, Charles Y; DeMarzo, Angelo M; Desai, Mihir M; Meler, James D; Donovan, James F; Klingler, Hans Christoph; Sopko, David R; Madden, John F; Marberger, Michael; Ferrandino, Michael N; Polascik, Thomas J

    2014-06-01

    To discuss the use of renal mass biopsy (RMB) for small renal masses (SRMs), formulate technical aspects, outline potential pitfalls and provide recommendations for the practicing clinician. The meeting was conducted as an informal consensus process and no scoring system was used to measure the levels of agreement on the different topics. A moderated general discussion was used as the basis for consensus and arising issues were resolved at this point. A consensus was established and lack of agreement to topics or specific items was noted at this point. Recommended biopsy technique: at least two cores, sampling different tumour regions with ultrasonography being the preferred method of image guidance. Pathological interpretation: 'non-diagnostic samples' should refer to insufficient material, inconclusive and normal renal parenchyma. For non-diagnostic samples, a repeat biopsy is recommended. Fine-needle aspiration may provide additional information but cannot substitute for core biopsy. Indications for RMB: biopsy is recommended in most cases except in patients with imaging or clinical characteristics indicative of pathology (syndromes, imaging characteristics) and cases whereby conservative management is not contemplated. RMB is recommended for active surveillance but not for watchful-waiting candidates. We report the results of an international consensus meeting on the use of RMB for SRMs, defining the technique, pathological interpretation and indications. © 2013 The Authors. BJU International © 2013 BJU International.

  4. An ultrahigh vacuum, low-energy ion-assisted deposition system for III-V semiconductor film growth

    NASA Astrophysics Data System (ADS)

    Rohde, S.; Barnett, S. A.; Choi, C.-H.

    1989-06-01

    A novel ion-assisted deposition system is described in which the substrate and growing film can be bombarded with high current densities (greater than 1 mA/sq cm) of very low energy (10-200 eV) ions. The system design philosophy is similar to that used in III-V semiconductor molecular-beam epitaxy systems: the chamber is an all-metal ultrahigh vacuum system with liquid-nitrogen-cooled shrouds, Knudsen-cell evaporation sources, a sample insertion load-lock, and a 30-kV reflection high-energy electron diffraction system. III-V semiconductor film growth is achieved using evaporated group-V fluxes and group-III elemental fluxes sputtered from high-purity targets using ions extracted from a triode glow discharge. Using an In target and an As effusion cell, InAs deposition rates R of 2 microns/h have been obtained. Epitaxial growth of InAs was observed on both GaSb(100) and Si(100) substrates.

  5. Aerosol Vacuum-Assisted Plasma Ionization (Aero-VaPI) Coupled to Ion Mobility-Mass Spectrometry

    NASA Astrophysics Data System (ADS)

    Blair, Sandra L.; Ng, Nga L.; Zambrzycki, Stephen C.; Li, Anyin; Fernández, Facundo M.

    2018-02-01

    In this communication, we report on the real-time analysis of organic aerosol particles by Vacuum-assisted Plasma Ionization-Mass Spectrometry (Aero-VaPI-MS) using a home-built VaPI ion source coupled to a Synapt G2-S HDMS ion mobility-mass spectrometry (IM-MS) system. Standards of organic molecules of interest in prebiotic chemistry were used to generate aerosols. Monocaprin and decanoic acid aerosol particles were successfully detected in both the positive and negative ion modes, respectively. A complex aerosol mixture of different sizes of polymers of L-malic acid was also examined through ion mobility (IM) separations, resulting in the detection of polymers of up to eight monomeric units. This noncommercial plasma ion source is proposed as a low cost alternative to other plasma ionization platforms used for aerosol analysis, and a higher-performance alternative to more traditional aerosol mass spectrometers. VaPI provides robust online ionization of organics in aerosols without extensive ion activation, with the coupling to IM-MS providing higher peak capacity and excellent mass accuracy. [Figure not available: see fulltext.

  6. PubMed Central

    Papathemelis, Thomas; Heim, Stefanie; Lux, Michael P.; Erhardt, Ines; Scharl, Anton; Scharl, Sophia

    2017-01-01

    Introduction We studied the extent to which an ultrasound-guided vacuum-assisted biopsy device (“hand-held Mammotome”) could be used not only as a valuable tool for investigation of suspicious breast lesions, but also therapeutically for the complete removal of breast fibroadenomas. Materials and Methods 132 aspiration biopsies showing fibroadenoma on histology were collected retrospectively. We ascertained whether there were residual findings on breast ultrasound at a median follow-up of approx. 9 months following biopsy. A questionnaire was used to determine the complication rate, patient satisfaction and acceptance of the procedure. Results In this study complete fibroadenomectomy was achieved at aspiration biopsy in 76 % of cases (n = 132). Compared to fibroadenomas larger than 2.51 cm3 (59 %), those smaller than 2.5 cm3 were completely removed more often (87.6 %; p < 0.05). The procedure is associated with very little pain during and after biopsy and minimal haematoma development, both factors supporting a high rate of acceptance among patients. Conclusion Ultrasound-guided vacuum-assisted biopsy is safe and associated with very few complications. Its additional therapeutic potential is dependant on the size of the benign lesion as measured at initial ultrasound. PMID:28331240

  7. Chronic baseline prostate inflammation is associated with lower tumor volume in men with prostate cancer on repeat biopsy: Results from the REDUCE study.

    PubMed

    Moreira, Daniel M; Nickel, J Curtis; Andriole, Gerald L; Castro-Santamaria, Ramiro; Freedland, Stephen J

    2015-09-01

    To evaluate whether baseline acute and chronic prostate inflammation among men with initial negative biopsy for prostate cancer (PC) is associated with PC volume at the 2-year repeat prostate biopsy in a clinical trial with systematic biopsies. Retrospective analysis of 886 men with negative baseline prostate biopsy and positive 2-year repeat biopsy in the Reduction by Dutasteride of PC Events (REDUCE) study. Acute and chronic inflammation and tumor volume were determined by central pathology. The association of baseline inflammation with 2-year repeat biopsy cancer volume was evaluated with linear and Poisson regressions controlling for demographics and laboratory variables. Chronic, acute inflammation, and both were detected in 531 (60%), 12 (1%), and 84 (9%) baseline biopsies, respectively. Acute and chronic inflammation were significantly associated with each other (P < 0.001). Chronic inflammation was associated with larger prostate (P < 0.001) and lower pre-repeat biopsy PSA (P = 0.01). At 2-year biopsy, baseline chronic inflammation was associated with lower mean tumor volume (2.07 µl vs. 3.15 µl; P = 0.001), number of biopsy cores involved (1.78 vs. 2.19; P < 0.001), percent of cores involved (17.8% vs. 22.8%; P < 0.001), core involvement (0.21 µl vs. 0.31 µl; P < 0.001), and overall percent tumor involvement (1.40% vs. 2.01%; P < 0.001). Results were unchanged in multivariable analysis. Baseline acute inflammation was not associated with any tumor volume measurement. In a cohort of men with 2-year repeat prostate biopsy positive for PC after a negative baseline biopsy, baseline chronic inflammation was associated with lower PC volume. © 2015 Wiley Periodicals, Inc.

  8. Analysis of histological findings obtained combining US/mp-MRI fusion-guided biopsies with systematic US biopsies: mp-MRI role in prostate cancer detection and false negative.

    PubMed

    Faiella, Eliodoro; Santucci, Domiziana; Greco, Federico; Frauenfelder, Giulia; Giacobbe, Viola; Muto, Giovanni; Zobel, Bruno Beomonte; Grasso, Rosario Francesco

    2018-02-01

    To evaluate the diagnostic accuracy of mp-MRI correlating US/mp-MRI fusion-guided biopsy with systematic random US-guided biopsy in prostate cancer diagnosis. 137 suspected prostatic abnormalities were identified on mp-MRI (1.5T) in 96 patients and classified according to PI-RADS score v2. All target lesions underwent US/mp-MRI fusion biopsy and prostatic sampling was completed by US-guided systematic random 12-core biopsies. Histological analysis and Gleason score were established for all the samples, both target lesions defined by mp-MRI, and random biopsies. PI-RADS score was correlated with the histological results, divided in three groups (benign tissue, atypia and carcinoma) and with Gleason groups, divided in four categories considering the new Grading system of the ISUP 2014, using t test. Multivariate analysis was used to correlate PI-RADS and Gleason categories to PSA level and abnormalities axial diameter. When the random core biopsies showed carcinoma (mp-MRI false-negatives), PSA value and lesions Gleason median value were compared with those of carcinomas identified by mp-MRI (true-positives), using t test. There was statistically significant difference between PI-RADS score in carcinoma, atypia and benign lesions groups (4.41, 3.61 and 3.24, respectively) and between PI-RADS score in Gleason < 7 group and Gleason > 7 group (4.14 and 4.79, respectively). mp-MRI performance was more accurate for lesions > 15 mm and in patients with PSA > 6 ng/ml. In systematic sampling, 130 (11.25%) mp-MRI false-negative were identified. There was no statistic difference in Gleason median value (7.0 vs 7.06) between this group and the mp-MRI true-positives, but a significant lower PSA median value was demonstrated (7.08 vs 7.53 ng/ml). mp-MRI remains the imaging modality of choice to identify PCa lesions. Integrating US-guided random sampling with US/mp-MRI fusion target lesions sampling, 3.49% of false-negative were identified.

  9. Interoperative Biopsy Site Relocalization in Endoluminal Surgery.

    PubMed

    Vemuri, Anant Suraj; Nicolau, Stephane; Sportes, Adrien; Marescaux, Jacques; Soler, Luc; Ayache, Nicholas

    2016-09-01

    Barrett's oesophagus, a premalignant condition of the oesophagus has been on a rise in the recent years. The standard diagnostic protocol for Barrett's involves obtaining biopsies at suspicious regions along the oesophagus. The localization and tracking of these biopsy sites "interoperatively" poses a significant challenge for providing targeted treatments and tracking disease progression. This paper proposes an approach to provide guided navigation and relocalization of the biopsy sites using an electromagnetic tracking system. The characteristic of our approach over existing ones is the integration of an electromagnetic sensor at the flexible endoscope tip, so that the endoscopic camera depth inside the oesophagus can be computed in real time, allowing to retrieve and display an image from a previous exploration at the same depth. We first describe our system setup and methodology for interoperative registration. We then propose three incremental experiments of our approach. First, on synthetic data with realistic noise model to analyze the error bounds of our system. The second on in vivo pig data using an optical tracking system to provide a pseudo ground truth. Accuracy results obtained were consistent with the synthetic experiments despite uncertainty introduced due to breathing motion, and remain inside acceptable error margin according to medical experts. Finally, a third experiment designed using data from pigs to simulate a real task of biopsy site relocalization, and evaluated by ten gastro-intestinal experts. It clearly demonstrated the benefit of our system toward assisted guidance by improving the biopsy site retrieval rate from 47.5% to 94%.

  10. Clinical practice guidelines from the French College of Gynecologists and Obstetricians (CNGOF): benign breast tumors - short text.

    PubMed

    Lavoué, Vincent; Fritel, Xavier; Antoine, Martine; Beltjens, Françoise; Bendifallah, Sofiane; Boisserie-Lacroix, Martine; Boulanger, Loic; Canlorbe, Geoffroy; Catteau-Jonard, Sophie; Chabbert-Buffet, Nathalie; Chamming's, Foucauld; Chéreau, Elisabeth; Chopier, Jocelyne; Coutant, Charles; Demetz, Julie; Guilhen, Nicolas; Fauvet, Raffaele; Kerdraon, Olivier; Laas, Enora; Legendre, Guillaume; Mathelin, Carole; Nadeau, Cédric; Naggara, Isabelle Thomassin; Ngô, Charlotte; Ouldamer, Lobna; Rafii, Arash; Roedlich, Marie-Noelle; Seror, Jérémy; Séror, Jean-Yves; Touboul, Cyril; Uzan, Catherine; Daraï, Emile

    2016-05-01

    Screening with breast ultrasound in combination with mammography is needed to investigate a clinical breast mass (Grade B), colored single-pore breast nipple discharge (Grade C), or mastitis (Grade C). The BI-RADS system is recommended for describing and classifying abnormal breast imaging findings. For a breast abscess, a percutaneous biopsy is recommended in the case of a mass or persistent symptoms (Grade C). For mastalgia, when breast imaging is normal, no MRI or breast biopsy is recommended (Grade C). Percutaneous biopsy is recommended for a BI-RADS category 4-5 mass (Grade B). For persistent erythematous nipple or atypical eczema lesions, a nipple biopsy is recommended (Grade C). For distortion and asymmetry, a vacuum core-needle biopsy is recommended due to the risk of underestimation by simple core-needle biopsy (Grade C). For BI-RADS category 4-5 microcalcifications without any ultrasound signal, a minimum 11-G vacuum core-needle biopsy is recommended (Grade B). In the absence of microcalcifications on radiography cores additional samples are recommended (Grade B). For atypical ductal hyperplasia, atypical lobular hyperplasia, lobular carcinoma in situ, flat epithelial atypia, radial scar and mucocele with atypia, surgical excision is commonly recommended (Grade C). Expectant management is feasible after multidisciplinary consensus. For these lesions, when excision margins are not clear, no new excision is recommended except for LCIS characterized as pleomorphic or with necrosis (Grade C). For grade 1 phyllodes tumor, surgical resection with clear margins is recommended. For grade 2 phyllodes tumor, 10mm margins are recommended (Grade C). For papillary breast lesions without atypia, complete disappearance of the radiological signal is recommended (Grade C). For papillary breast lesions with atypia, complete surgical excision is recommended (Grade C). Copyright © 2016 Elsevier Ireland Ltd. All rights reserved.

  11. Magnetic resonance imaging-targeted, 3D transrectal ultrasound-guided fusion biopsy for prostate cancer: Quantifying the impact of needle delivery error on diagnosis

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Martin, Peter R., E-mail: pmarti46@uwo.ca; Cool, Derek W.; Romagnoli, Cesare

    2014-07-15

    Purpose: Magnetic resonance imaging (MRI)-targeted, 3D transrectal ultrasound (TRUS)-guided “fusion” prostate biopsy intends to reduce the ∼23% false negative rate of clinical two-dimensional TRUS-guided sextant biopsy. Although it has been reported to double the positive yield, MRI-targeted biopsies continue to yield false negatives. Therefore, the authors propose to investigate how biopsy system needle delivery error affects the probability of sampling each tumor, by accounting for uncertainties due to guidance system error, image registration error, and irregular tumor shapes. Methods: T2-weighted, dynamic contrast-enhanced T1-weighted, and diffusion-weighted prostate MRI and 3D TRUS images were obtained from 49 patients. A radiologist and radiologymore » resident contoured 81 suspicious regions, yielding 3D tumor surfaces that were registered to the 3D TRUS images using an iterative closest point prostate surface-based method to yield 3D binary images of the suspicious regions in the TRUS context. The probabilityP of obtaining a sample of tumor tissue in one biopsy core was calculated by integrating a 3D Gaussian distribution over each suspicious region domain. Next, the authors performed an exhaustive search to determine the maximum root mean squared error (RMSE, in mm) of a biopsy system that gives P ≥ 95% for each tumor sample, and then repeated this procedure for equal-volume spheres corresponding to each tumor sample. Finally, the authors investigated the effect of probe-axis-direction error on measured tumor burden by studying the relationship between the error and estimated percentage of core involvement. Results: Given a 3.5 mm RMSE for contemporary fusion biopsy systems,P ≥ 95% for 21 out of 81 tumors. The authors determined that for a biopsy system with 3.5 mm RMSE, one cannot expect to sample tumors of approximately 1 cm{sup 3} or smaller with 95% probability with only one biopsy core. The predicted maximum RMSE giving P ≥ 95% for

  12. Tumor Content Chart-Assisted HER2/CEP17 Digital PCR Analysis of Gastric Cancer Biopsy Specimens.

    PubMed

    Matsusaka, Keisuke; Ishikawa, Shumpei; Nakayama, Atsuhito; Ushiku, Tetsuo; Nishimoto, Aiko; Urabe, Masayuki; Kaneko, Nobuyuki; Kunita, Akiko; Kaneda, Atsushi; Aburatani, Hiroyuki; Fujishiro, Mitsuhiro; Seto, Yasuyuki; Fukayama, Masashi

    2016-01-01

    Evaluating HER2 gene amplification is an essential component of therapeutic decision-making for advanced or metastatic gastric cancer. A simple method that is applicable to small, formalin-fixed, paraffin-embedded biopsy specimens is desirable as an adjunct to or as a substitute for currently used HER2 immunohistochemistry and in situ hybridization protocols. In this study, we developed a microfluidics-based digital PCR method for determining HER2 and chromosome 17 centromere (CEP17) copy numbers and estimating tumor content ratio (TCR). The HER2/CEP17 ratio is determined by three variables-TCR and absolute copy numbers of HER2 and CEP17-by examining tumor cells; only the ratio of the latter two can be obtained by digital PCR using the whole specimen without purifying tumor cells. TCR was determined by semi-automatic image analysis. We developed a Tumor Content chart, which is a plane of rectangular coordinates consisting of HER2/CEP17 digital PCR data and TCR that delineates amplified, non-amplified, and equivocal areas. By applying this method, 44 clinical gastric cancer biopsy samples were classified as amplified (n = 13), non-amplified (n = 25), or equivocal (n = 6). By comparison, 11 samples were positive, 11 were negative, and 22 were equivocally immunohistochemistry. Thus, our novel method reduced the number of equivocal samples from 22 to 6, thereby obviating the need for confirmation by fluorescence or dual-probe in situ hybridization to < 30% of cases. Tumor content chart-assisted digital PCR analysis is also applicable to multiple sites in surgically resected tissues. These results indicate that this analysis is a useful alternative to HER2 immunohistochemistry in gastric cancers that can serve as a basis for the automated evaluation of HER2 status.

  13. Tumor Content Chart-Assisted HER2/CEP17 Digital PCR Analysis of Gastric Cancer Biopsy Specimens

    PubMed Central

    Matsusaka, Keisuke; Ishikawa, Shumpei; Nakayama, Atsuhito; Ushiku, Tetsuo; Nishimoto, Aiko; Urabe, Masayuki; Kaneko, Nobuyuki; Kunita, Akiko; Kaneda, Atsushi; Aburatani, Hiroyuki; Fujishiro, Mitsuhiro; Seto, Yasuyuki; Fukayama, Masashi

    2016-01-01

    Evaluating HER2 gene amplification is an essential component of therapeutic decision-making for advanced or metastatic gastric cancer. A simple method that is applicable to small, formalin-fixed, paraffin-embedded biopsy specimens is desirable as an adjunct to or as a substitute for currently used HER2 immunohistochemistry and in situ hybridization protocols. In this study, we developed a microfluidics-based digital PCR method for determining HER2 and chromosome 17 centromere (CEP17) copy numbers and estimating tumor content ratio (TCR). The HER2/CEP17 ratio is determined by three variables—TCR and absolute copy numbers of HER2 and CEP17—by examining tumor cells; only the ratio of the latter two can be obtained by digital PCR using the whole specimen without purifying tumor cells. TCR was determined by semi-automatic image analysis. We developed a Tumor Content chart, which is a plane of rectangular coordinates consisting of HER2/CEP17 digital PCR data and TCR that delineates amplified, non-amplified, and equivocal areas. By applying this method, 44 clinical gastric cancer biopsy samples were classified as amplified (n = 13), non-amplified (n = 25), or equivocal (n = 6). By comparison, 11 samples were positive, 11 were negative, and 22 were equivocally immunohistochemistry. Thus, our novel method reduced the number of equivocal samples from 22 to 6, thereby obviating the need for confirmation by fluorescence or dual-probe in situ hybridization to < 30% of cases. Tumor content chart-assisted digital PCR analysis is also applicable to multiple sites in surgically resected tissues. These results indicate that this analysis is a useful alternative to HER2 immunohistochemistry in gastric cancers that can serve as a basis for the automated evaluation of HER2 status. PMID:27119558

  14. Upgrading the Gleason Score in Extended Prostate Biopsy: Implications for Treatment Choice

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Moreira Leite, Katia Ramos; Laboratory of Surgical and Molecular Pathology - Hospital Sirio Libanes, Sao Paulo; Camara-Lopes, Luiz H.A.

    2009-02-01

    Purpose: To determine the incidence of overestimation of Gleason score (GS) in extended prostate biopsy, and consequently circumventing unnecessary aggressive treatment. Methods and Materials: This is a retrospective study of 464 patients who underwent prostate biopsy and radical prostatectomy between January 2001 and November 2007. The GS from biopsy and radical prostatectomy were compared. The incidence of overestimation of GS in biopsies and tumor volume were studied. Multivariate analysis was applied to find parameters that predict upgrading the GS in prostate biopsy. Results: The exact agreement of GS between prostate biopsy and radical prostatectomy occurred in 56.9% of cases. Inmore » 29.1% cases it was underestimated, and it was overestimated in 14%. One hundred and six (22.8%) patients received a diagnosis of high GS (8, 9, or 10) in a prostate biopsy. In 29.2% of cases, the definitive Gleason Score was 7 or lower. In cases in which GS was overestimated in the biopsy, tumors were significantly smaller. In multivariate analysis, the total percentage of tumor was the only independent factor in overestimation of GS. Tumors occupying less than 33% of cores had a 5.6-fold greater chance of being overestimated. Conclusion: In the extended biopsy era and after the International Society of Urological Pathology consensus on GS, almost one third of tumors considered to have high GS at the biopsy may be intermediate-risk cancers. In that condition, tumors are smaller in biopsy. This should be remembered by professionals involved with prostate cancer to avoid overtreatment and undesirable side effects.« less

  15. Endometrial biopsy

    MedlinePlus

    ... Names Biopsy - endometrium Images Pelvic laparoscopy Female reproductive anatomy Endometrial biopsy Uterus Endometrial biopsy References Beard JM, Osborn J. Common office procedures. In: Rakel RE, Rakel DP, eds. Textbook of Family Medicine . 9th ed. Philadelphia, PA: Elsevier ...

  16. Resin Flow Behavior Simulation of Grooved Foam Sandwich Composites with the Vacuum Assisted Resin Infusion (VARI) Molding Process

    PubMed Central

    Zhao, Chenhui; Zhang, Guangcheng; Wu, Yibo

    2012-01-01

    The resin flow behavior in the vacuum assisted resin infusion molding process (VARI) of foam sandwich composites was studied by both visualization flow experiments and computer simulation. Both experimental and simulation results show that: the distribution medium (DM) leads to a shorter molding filling time in grooved foam sandwich composites via the VARI process, and the mold filling time is linearly reduced with the increase of the ratio of DM/Preform. Patterns of the resin sources have a significant influence on the resin filling time. The filling time of center source is shorter than that of edge pattern. Point pattern results in longer filling time than of linear source. Short edge/center patterns need a longer time to fill the mould compared with Long edge/center sources.

  17. Skin Biopsy

    MedlinePlus

    ... Staying Safe Videos for Educators Search English Español Skin Biopsy KidsHealth / For Teens / Skin Biopsy What's in ... en español Biopsia de piel What Is a Skin Biopsy and Who Would Need One? In a ...

  18. Magnetic resonance imaging-ultrasound fusion biopsy for prediction of final prostate pathology.

    PubMed

    Le, Jesse D; Stephenson, Samuel; Brugger, Michelle; Lu, David Y; Lieu, Patricia; Sonn, Geoffrey A; Natarajan, Shyam; Dorey, Frederick J; Huang, Jiaoti; Margolis, Daniel J A; Reiter, Robert E; Marks, Leonard S

    2014-11-01

    We explored the impact of magnetic resonance imaging-ultrasound fusion prostate biopsy on the prediction of final surgical pathology. A total of 54 consecutive men undergoing radical prostatectomy at UCLA after fusion biopsy were included in this prospective, institutional review board approved pilot study. Using magnetic resonance imaging-ultrasound fusion, tissue was obtained from a 12-point systematic grid (mapping biopsy) and from regions of interest detected by multiparametric magnetic resonance imaging (targeted biopsy). A single radiologist read all magnetic resonance imaging, and a single pathologist independently rereviewed all biopsy and whole mount pathology, blinded to prior interpretation and matched specimen. Gleason score concordance between biopsy and prostatectomy was the primary end point. Mean patient age was 62 years and median prostate specific antigen was 6.2 ng/ml. Final Gleason score at prostatectomy was 6 (13%), 7 (70%) and 8-9 (17%). A tertiary pattern was detected in 17 (31%) men. Of 45 high suspicion (image grade 4-5) magnetic resonance imaging targets 32 (71%) contained prostate cancer. The per core cancer detection rate was 20% by systematic mapping biopsy and 42% by targeted biopsy. The highest Gleason pattern at prostatectomy was detected by systematic mapping biopsy in 54%, targeted biopsy in 54% and a combination in 81% of cases. Overall 17% of cases were upgraded from fusion biopsy to final pathology and 1 (2%) was downgraded. The combination of targeted biopsy and systematic mapping biopsy was needed to obtain the best predictive accuracy. In this pilot study magnetic resonance imaging-ultrasound fusion biopsy allowed for the prediction of final prostate pathology with greater accuracy than that reported previously using conventional methods (81% vs 40% to 65%). If confirmed, these results will have important clinical implications. Copyright © 2014 American Urological Association Education and Research, Inc. Published by

  19. Multi-Quadrant Biopsy Technique Improves Diagnostic Ability in Large Heterogeneous Renal Masses.

    PubMed

    Abel, E Jason; Heckman, Jennifer E; Hinshaw, Louis; Best, Sara; Lubner, Meghan; Jarrard, David F; Downs, Tracy M; Nakada, Stephen Y; Lee, Fred T; Huang, Wei; Ziemlewicz, Timothy

    2015-10-01

    Percutaneous biopsy obtained from a single location is prone to sampling error in large heterogeneous renal masses, leading to nondiagnostic results or failure to detect poor prognostic features. We evaluated the accuracy of percutaneous biopsy for large renal masses using a modified multi-quadrant technique vs a standard biopsy technique. Clinical and pathological data for all patients with cT2 or greater renal masses who underwent percutaneous biopsy from 2009 to 2014 were reviewed. The multi-quadrant technique was defined as multiple core biopsies from at least 4 separate solid enhancing areas in the tumor. The incidence of nondiagnostic findings, sarcomatoid features and procedural complications was recorded, and concordance between biopsy specimens and nephrectomy pathology was compared. A total of 122 biopsies were performed for 117 tumors in 116 patients (46 using the standard biopsy technique and 76 using the multi-quadrant technique). Median tumor size was 10 cm (IQR 8-12). Biopsy was nondiagnostic in 5 of 46 (10.9%) standard and 0 of 76 (0%) multi-quadrant biopsies (p=0.007). Renal cell carcinoma was identified in 96 of 115 (82.0%) tumors and nonrenal cell carcinoma tumors were identified in 21 (18.0%). One complication occurred using the standard biopsy technique and no complications were reported using the multi-quadrant technique. Sarcomatoid features were present in 23 of 96 (23.9%) large renal cell carcinomas studied. Sensitivity for identifying sarcomatoid features was higher using the multi-quadrant technique compared to the standard biopsy technique at 13 of 15 (86.7%) vs 2 of 8 (25.0%) (p=0.0062). The multi-quadrant percutaneous biopsy technique increases the ability to identify aggressive pathological features in large renal tumors and decreases nondiagnostic biopsy rates. Copyright © 2015 American Urological Association Education and Research, Inc. Published by Elsevier Inc. All rights reserved.

  20. Fiber laser with combined feedback of core and cladding modes assisted by an intracavity long-period grating.

    PubMed

    Sáez-Rodriguez, D; Cruz, J L; Díez, A; Andrés, M V

    2011-05-15

    We present a fiber laser made in a single piece of conventional doped-core fiber that operates by combined feedback of the fundamental core mode LP((0,1)) and the high-order cladding mode LP((0,10)). The laser is an all-fiber structure that uses two fiber Bragg gratings and a long-period grating to select the modes circulating in the cavity; the laser emits at the coupling wavelength between the core mode LP((0,1)) and the counterpropagating cladding mode LP((0,10)) in the Bragg gratings. This work demonstrates the feasibility of high-order mode fiber lasers assisted by long-period gratings. © 2011 Optical Society of America

  1. 3+4 = 6? Implications of the stratification of localised Gleason 7 prostate cancer by number and percentage of positive biopsy cores in selecting patients for active surveillance.

    PubMed

    Ruiz-Cerdá, J L; Lorenzo Soriano, L; Ramos-Soler, D; Marzullo-Zucchet, L; Loras Monfort, A; Boronat Tormo, F

    2018-03-01

    To determine whether the number and percentage of positive biopsy cores identify a Gleason 3+4 prostate cancer (PC) subgroup of similar biologic behaviour to Gleason 3+3. An observational post-radical prostatectomy study was conducted of a cohort of 799 patients with localised low-risk (n=582, Gleason 6, PSA <10ng/ml and cT1c-2a) and favourable intermediate PC (n=217, Gleason 3+4, PSA ≤10 ng/ml and pT2abc). The Gleason 3+4 tumours were stratified by number (≤3 vs.>3) and by percentage of positive cores (≤33% vs. >33%). We analysed the tumours' association with the biochemical recurrence risk (BRR) and cancer-specific mortality (CSM). We conducted various predictive models using Cox regression and estimated (C-index) and compared their predictive capacity. With a median follow-up of 71 months, the BRR and CSM of the patient group with Gleason 3+4 tumours and a low number (≤3) and percentage (≤33%) of positive cores were not significantly different from those of the patients with Gleason 6 tumours. At 5 and 10 years, there were no significant differences in the number of biochemical recurrences, the probability of remaining free of biochemical recurrences, the number of deaths by PC or the probability of death by PC between the 2 groups. In contrast, the patients with Gleason 3+4 tumours and more than 33% of positive cores presented more deaths by PC than the patients with Gleason 6 tumours. At 10 years, the probability of CSM was significantly greater. This subgroup of tumours showed a significantly greater BRR (RR, 1.6; P=.02) and CSM (RR, 5.8, P≤.01) compared with the Gleason 6 tumours. The model with Gleason 3+4 stratified by the percentage of positive cores significantly improved the predictive capacity of BRR and CSM. Fewer than 3 cores and a percentage <33% of positive cores identifies a subgroup of Gleason 3+4 tumours with biological behaviour similar to Gleason 6 tumours. At 10 years, there were no differences in BRR and CSM between the 2 groups

  2. Male breast cancer is rare: an initial presentation may be as an abscess.

    PubMed

    Ventham, N T; Hussien, M I

    2010-08-06

    Breast cancer in men is rare. Breast cancer presenting initially as an abscess has been described only a handful of times in the literature. We present the first described case of invasive adenocarcinoma presenting as an abscess in a man. An 80-year-old diabetic man presented with symptoms typical of a breast abscess. The abscess failed to respond to percutaneous therapy and excision of breast abscess was performed. Histology revealed an invasive carcinoma. He went on to have a mastectomy. Histology should be obtained from breast abscesses not resolving within 2 months of initial percutaneous therapy. Histology could be obtained by ultrasound-guided fine-needle aspiration (FNA), core or vacuum assisted biopsy, or by formal incision and drainage.

  3. Gastric Cancer-Specific Protein Profile Identified Using Endoscopic Biopsy Samples via MALDI Mass Spectrometry

    PubMed Central

    Kim, Hark Kyun; Reyzer, Michelle L.; Choi, Il Ju; Kim, Chan Gyoo; Kim, Hee Sung; Oshima, Akira; Chertov, Oleg; Colantonio, Simona; Fisher, Robert J.; Allen, Jamie L.; Caprioli, Richard M.; Green, Jeffrey E.

    2012-01-01

    To date, proteomic analyses on gastrointestinal cancer tissue samples have been performed using surgical specimens only, which are obtained after a diagnosis is made. To determine if a proteomic signature obtained from endoscopic biopsy samples could be found to assist with diagnosis, frozen endoscopic biopsy samples collected from 63 gastric cancer patients and 43 healthy volunteers were analyzed using matrix-assisted laser desorption/ionization (MALDI) mass spectrometry. A statistical classification model was developed to distinguish tumor from normal tissues using half the samples and validated with the other half. A protein profile was discovered consisting of 73 signals that could classify 32 cancer and 22 normal samples in the validation set with high predictive values (positive and negative predictive values for cancer, 96.8% and 91.3%; sensitivity, 93.8%; specificity, 95.5%). Signals overexpressed in tumors were identified as α-defensin-1, α-defensin-2, calgranulin A, and calgranulin B. A protein profile was also found to distinguish pathologic stage Ia (pT1N0M0) samples (n = 10) from more advanced stage (Ib or higher) tumors (n = 48). Thus, protein profiles obtained from endoscopic biopsy samples may be useful in assisting with the diagnosis of gastric cancer and, possibly, in identifying early stage disease. PMID:20557134

  4. Evaluation of rapid readout biological indicators for 132 degrees C gravity and 132 degrees C vacuum-assisted steam sterilization cycles using a new automated fluorescent reader.

    PubMed

    Alfa, Michelle J; Olson, Nancy; DeGagne, Pat; Jackson, Michele

    2002-07-01

    The primary objective of this study was to evaluate fluorescent readout results of Attest 1291 Biological Indicators (BIs) (3M Health Care, St. Paul, MN) and Attest 1296 BI test packs (containing Attest 1292 BIs) using full and fractional cycles compared with the growth data when prolonged incubation (7 days) was included. Gravity displacement and vacuum-assisted steam sterilization cycles were evaluated. A secondary objective of this study was to evaluate the new automated rapid fluorescent reader (Attest 290 Auto Reader). The rapid readout BIs for gravity displacement and vacuum-assisted steam autoclave cycles at 132 degrees C were processed using full (4 minutes) and four fractional cycles that provided 30% to 80% positive results for growth after 24 hours of incubation (48 hours of incubation for Attest 1292 BIs from the Attest 1296 test packs). Sixty of each type of BI were tested for each cycle (300 of each BI type in total). For all full steam sterilization cycles, results of the rapid fluorescent readout and the 24-hour, 48-hour, and 7-day growth tests were negative for all Attest 1291 and 1292 BIs tested. For all fractional cycles, the 24- and 48-hour growth results for the Attest 1291 and 1292 BIs, respectively, were the same as the 7-day growth results. The fractional cycle data indicated that fluorescent rapid readout was a more sensitive indicator than growth. There were rare (0.9%) false-negative results for BIs under fractional cycle conditions and these all correlated with short fractional cycle exposure times. The fluorescent rapid readout results of the 1291 BIs and 1296 BI test packs reliably predict both 24- and 48-hour and 7-day growth. These data support the value of rapid readout BIs for sterilizer monitoring for both the vacuum-assisted and the gravity displacement steam sterilization cycles. The new automated reader requires less manipulation of the BI and makes monitoring user friendly and less prone to user errors.

  5. Processing and Properties of Vacuum Assisted Resin Transfer Molded Phenylethynyl Terminated Imide Composites

    NASA Technical Reports Server (NTRS)

    Cano, Roberto J.; Ghose, Sayata; Watson, Kent A.; Chunchu, Prasad B.; Jensen, Brian J.; Connell, John W.

    2012-01-01

    Polyimide composites are very attractive for applications that require a high strength to weight ratio and thermal stability. Recent work at NASA Langley Research Center (LaRC) has concentrated on developing new polyimide resin systems that can be processed without the use of an autoclave for advanced aerospace applications. Due to their low melt viscosities and long melt stability, certain phenylethynyl terminated imides (PETI) can be processed into composites using high temperature vacuum assisted resin transfer molding (HT-VARTM). VARTM has shown the potential to reduce the manufacturing cost of composite structures. In the current study, two PETI resins, LARC(Trademark) PETI-330 and LARC(Trademark) PETI-9, were infused into carbon fiber preforms at 260 C and cured at temperatures up to 371 C. Photomicrographs of polished cross sections were taken and void contents, determined by acid digestion, were below 4.5%. Mechanical properties including short block compression (SBC), compression after impact (CAI), and open hole compression (OHC) were determined at room temperature, 177 C, and 288 C. Both PETI-9 and PETI-330 composites demonstrated very good retention of mechanical properties at elevated temperatures. SBC and OHC properties after aging for 1000 hours at temperatures up to 288 C were also determined.

  6. Cup detachment during vacuum-assisted vaginal delivery and birth outcome.

    PubMed

    Krispin, Eyal; Aviram, Amir; Salman, Lina; Chen, Rony; Wiznitzer, Arnon; Gabbay-Benziv, Rinat

    2017-11-01

    To determine the perinatal outcome associated with cup detachment during vacuum-assisted vaginal delivery (VAVD). A retrospective cohort study of all women attempting VAVD in a tertiary hospital (2012-2014). Singleton-term pregnancies were included. Antepartum fetal death and major fetal structural or chromosomal abnormalities were excluded. Primary outcome was neonatal birth trauma (subgaleal hematoma, subarachnoid hematoma, subdural hematoma, skull fracture, and/or erb's palsy). Secondary outcomes were maternal complications or other neonatal morbidities. Outcomes were compared between women after ≥1 cup detachment (study group) and the rest (control group). Logistic regression analysis was utilized to adjust results to potential confounders. Overall, 1779 women attempted VAVD during study period. Of them, in 146 (8.2%), the cup detached prior to delivery; 130/146 (89%) had a single detachment. After detachment, 4 (2.7%) delivered by cesarean section, 77 (52.7%) delivered after cup reapplication, and 65 (44.6%) delivered spontaneously. Women in the study group were more likely to undergo VAVD due to prolonged second stage, and were characterized by lower rates of metal cup use. Neonates in the detachment group had higher rates of subarachnoid hematoma and composite neonatal birth trauma (2.7 vs. 0.1% and 4.8 vs. 1.8%, respectively, p < 0.05). This remained significant after adjustment to potential confounders (subarachnoid hematoma aOR = 45.44, 95% CI 6.42-321.62 and neonatal birth trauma aOR = 2.62, 95% CI 1.1-6.22, p < 0.05 for all). Other neonatal and maternal morbidities were similar between groups. Cup detachment is associated with a higher rate of adverse neonatal outcome. Cup reapplication should be considered carefully.

  7. Flat epithelial atypia on breast needle core biopsy: a retrospective study with clinical-pathological correlation.

    PubMed

    Lee, Tsu-Yee Joseph; Macintosh, Rebecca F; Rayson, Daniel; Barnes, Penny J

    2010-01-01

    There are limited data to guide clinical management when flat epithelial atypia (FEA) is identified in breast needle core biopsies (NCBs). Our objectives were to determine the frequency of malignancy in subsequent breast excisions following NCB diagnosis of FEA, and to characterize the pathological and clinical features of associated tumors. Two hundred and fifty-six breast NCBs from a retrospective search (January 1999-July 2007) were blindly reviewed for FEA/other columnar cell lesions (CCLs). NCBs with co-existing carcinoma were excluded. The study included 211 NCBs: 116 (55%) with CCLs without atypia; 40 (19%) with CCLs with atypical ductal hyperplasia (ADH), 15 (7%) with FEA and 40 (19%) with FEA and ADH; 94 cases had follow-up excisions. Ductal carcinoma in situ and/or invasive carcinoma were present in: 4/26 (15%) excisions with CCLs on NCB, 11/30 (37%) with CCLs + ADH, 1/7 (14%) with FEA alone, and 9/31 (29%) with FEA + ADH. (a) FEA was more frequently seen with ADH, than without ADH in NCBs, (b) FEA and CCLs were more frequently associated with malignancy when with ADH, and (c) tumors excised following NCB diagnosis of FEA+/-ADH had favorable prognostic factors. A conservative excision is warranted following a NCB diagnosis of FEA and ADH, and may be warranted for FEA alone.

  8. Prostate cancer detection in patients with prior negative biopsy undergoing cognitive-, robotic- or in-bore MRI target biopsy.

    PubMed

    Kaufmann, Sascha; Russo, Giorgio I; Bamberg, Fabian; Löwe, Lorenz; Morgia, Giuseppe; Nikolaou, Konstantin; Stenzl, Arnulf; Kruck, Stephan; Bedke, Jens

    2018-05-01

    To evaluate the detection rate among three different targeted biopsy approaches of robot-assisted MRI/TRUS fusion (RA-TB), mpMRI in-bore (MRGB), cognitive fusion guidance biopsy (COG-TB) for the detection of prostate cancer (PC) and clinically significant PC (csPC). Between 2014 and 2016, 156 patients with a lesion on mpMRI, performed in accordance with ESUR guidelines, due to cancer suspicion or on-going cancer suspicion after prior negative prostate biopsy, underwent targeted biopsy with RA-TB, MRGB or COG-TB. All lesions were rated according to PI-RADS v2. We compared detection rates between techniques. Models were constructed to predict the detection of overall PC and csPC and using a 1000 boot-strap sample. In the all cohort, 73, 45 and 38 patients underwent RA-TB, MRGB or COG-TB, respectively. Overall PC was found in 39 (52.42%), 23 (51.11%) and 11 (28.95%) (p = 0.04) patients of RA-TB, MRGB and COG-TB arm, respectively. As concerning the detection of csPC, it was found in 26 (35.62%),18 (40.0%) and 9 (23.68%) patients of RA-TB, MRGB and COG-TB arm (p = 0.27). Model 1 showed that RA-TB [OR: 10.08 (95% CI 1.95-51.97); p < 0.01] and MRGB [OR: 12.88 (95% CI 2.36-70.25); p < 0.01] were associated with overall PC detection in TB, while only MRGB was associated with csPC at TB (model 2) [OR: 5.72; (95% CI 1.40-23.35); p < 0.01]. The c-index for model 1 and model 2 was 0.86 and 0.85, respectively. We did not report significant complications between groups. In-bore biopsy and MRI/TRUS fusion-guided biopsy showed greater accuracy in detecting PC compared to cognitive fusion as modeled in a newly established normogram.

  9. Vacuum force

    NASA Astrophysics Data System (ADS)

    Han, Yongquan

    2015-03-01

    To study on vacuum force, we must clear what is vacuum, vacuum is a space do not have any air and also ray. There is not exist an absolute the vacuum of space. The vacuum of space is relative, so that the vacuum force is relative. There is a certain that vacuum vacuum space exists. In fact, the vacuum space is relative, if the two spaces compared to the existence of relative vacuum, there must exist a vacuum force, and the direction of the vacuum force point to the vacuum region. Any object rotates and radiates. Rotate bend radiate- centripetal, gravity produced, relative gravity; non gravity is the vacuum force. Gravity is centripetal, is a trend that the objects who attracted wants to Centripetal, or have been do Centripetal movement. Any object moves, so gravity makes the object curve movement, that is to say, the radiation range curve movement must be in the gravitational objects, gravity must be existed in non vacuum region, and make the object who is in the region of do curve movement (for example: The earth moves around the sun), or final attracted in the form gravitational objects, and keep relatively static with attract object. (for example: objects on the earth moves but can't reach the first cosmic speed).

  10. Management of benign papilloma without atypia diagnosed at ultrasound-guided core needle biopsy: Scoring system for predicting malignancy.

    PubMed

    Ahn, Soo Kyung; Han, Wonshik; Moon, Hyeong-Gon; Kim, Min Kyoon; Noh, Dong-Young; Jung, Bong-Wha; Kim, Sung-Won; Ko, Eunyoung

    2018-01-01

    The management of benign intraductal papilloma diagnosed on core needle biopsy (CNB) remains unclear. This study was designed to evaluate factors predicting malignancy in patients diagnosed with benign papilloma without atypia at ultrasound-guided CNB and to develop a scoring system predicting malignancy based on clinical, radiological and pathological factors on further excisional biopsy. The study enrolled patients diagnosed with benign papillomas (including benign and atypical papillary lesions) at CNB. Multivariate analysis was used to identify relevant clinical, radiological and pathological factors that may predict malignancy. A total of 520 CNBs were diagnosed with benign or atypical papilloma. Of these, 452 were benign papilloma without atypia. Of the 250 lesions subsequently excised surgically from 234 women, 17 (6.8%) were diagnosed with malignancy. Multivariate analysis revealed that bloody nipple discharge, size on imaging ≥15 mm, BI-RADS≥4b, peripheral location and palpability were independent predictors of malignancy. A scoring system was developed based on logistic regression models and beta coefficients for each variable. The area under the ROC curve was 0.947 (95% CI: 0.913-0.981, p < 0.001) and a negative predictive value was 100%. In a validation set of 62 patients, an area under the ROC curve was 0.926 (95% CI: 0.857-0.995, p < 0.001). A scoring system predicting malignancy in patients diagnosed by CNB with benign papilloma without atypia was developed. This system was able to identify a subset of patients with lesions likely to be benign, indicating that imaging follow-up rather than surgical excision may be appropriate. Copyright © 2017 Elsevier Ltd, BASO ~ The Association for Cancer Surgery, and the European Society of Surgical Oncology. All rights reserved.

  11. An investigation into false-negative transthoracic fine needle aspiration and core biopsy specimens.

    PubMed

    Minot, Douglas M; Gilman, Elizabeth A; Aubry, Marie-Christine; Voss, Jesse S; Van Epps, Sarah G; Tuve, Delores J; Sciallis, Andrew P; Henry, Michael R; Salomao, Diva R; Lee, Peter; Carlson, Stephanie K; Clayton, Amy C

    2014-12-01

    Transthoracic fine needle aspiration (TFNA)/core needle biopsy (CNB) under computed tomography (CT) guidance has proved useful in the assessment of pulmonary nodules. We sought to determine the TFNA false-negative (FN) rate at our institution and identify potential causes of FN diagnoses. Medical records were reviewed from 1,043 consecutive patients who underwent CT-guided TFNA with or without CNB of lung nodules over a 5-year time period (2003-2007). Thirty-seven FN cases of "negative" TFNA/CNB with malignant outcome were identified with 36 cases available for review, of which 35 had a corresponding CNB. Cases were reviewed independently (blinded to original diagnosis) by three pathologists with 15 age- and sex-matched positive and negative controls. Diagnosis (i.e., nondiagnostic, negative or positive for malignancy, atypical or suspicious) and qualitative assessments were recorded. Consensus diagnosis was suspicious or positive in 10 (28%) of 36 TFNA cases and suspicious in 1 (3%) of 35 CNB cases, indicating potential interpretive errors. Of the 11 interpretive errors (including both suspicious and positive cases), 8 were adenocarcinomas, 1 squamous cell carcinoma, 1 metastatic renal cell carcinoma, and 1 lymphoma. The remaining 25 FN cases (69.4%) were considered sampling errors and consisted of 7 adenocarcinomas, 3 nonsmall cell carcinomas, 3 lymphomas, 2 squamous cell carcinomas, and 2 renal cell carcinomas. Interpretive and sampling error cases were more likely to abut the pleura, while histopathologically, they tended to be necrotic and air-dried. The overall FN rate in this patient cohort is 3.5% (1.1% interpretive and 2.4% sampling errors). © 2014 Wiley Periodicals, Inc.

  12. Ambient Profiling of Phenolic Content in Tea Infusions by Matrix-Assisted Ionization in Vacuum

    NASA Astrophysics Data System (ADS)

    Cody, Robert B.

    2018-05-01

    Matrix-assisted ionization in vacuum (MAIV) was used to analyze the polyphenol content of ten different tea infusions. Nine different Camellia sinensis infusions were analyzed including three green teas, two black teas, two oolong teas, jasmine tea, and white tea. An infusion of rooibos (Aspalathus linearis) tea was also analyzed. Each freshly brewed tea was diluted 1:1 with methanol, and 100 ppm of phenolphthalein was added as an internal standard. An excess of 3-nitrobenzonitrile (NBN) was added to each vial, and the solution containing NBN crystals was analyzed by aspiration directly into the mass spectrometer sampling orifice. A working curve constructed for dilutions of catechin with phenolphthalein internal standard showed good linearity for five replicates of each concentration. The measured relative abundances of flavonoid polyphenols in each tea were in good agreement with previously reported values. Polyphenol content in tea infusions varied from 19.2 to 108.6 mg 100 mL-1. In addition to the expected catechin flavonoids, abundant quinic acid and gallic acid was detected in the C. sinensis infusions. Characteristic A. linearis flavonoids were detected in the rooibos tea.

  13. A Contemporary Prostate Biopsy Risk Calculator Based on Multiple Heterogeneous Cohorts.

    PubMed

    Ankerst, Donna P; Straubinger, Johanna; Selig, Katharina; Guerrios, Lourdes; De Hoedt, Amanda; Hernandez, Javier; Liss, Michael A; Leach, Robin J; Freedland, Stephen J; Kattan, Michael W; Nam, Robert; Haese, Alexander; Montorsi, Francesco; Boorjian, Stephen A; Cooperberg, Matthew R; Poyet, Cedric; Vertosick, Emily; Vickers, Andrew J

    2018-05-16

    Prostate cancer prediction tools provide quantitative guidance for doctor-patient decision-making regarding biopsy. The widely used online Prostate Cancer Prevention Trial Risk Calculator (PCPTRC) utilized data from the 1990s based on six-core biopsies and outdated grading systems. We prospectively gathered data from men undergoing prostate biopsy in multiple diverse North American and European institutions participating in the Prostate Biopsy Collaborative Group (PBCG) in order to build a state-of-the-art risk prediction tool. We obtained data from 15 611 men undergoing 16 369 prostate biopsies during 2006-2017 at eight North American institutions for model-building and three European institutions for validation. We used multinomial logistic regression to estimate the risks of high-grade prostate cancer (Gleason score ≥7) on biopsy based on clinical characteristics, including age, prostate-specific antigen, digital rectal exam, African ancestry, first-degree family history, and prior negative biopsy. We compared the PBCG model to the PCPTRC using internal cross-validation and external validation on the European cohorts. Cross-validation on the North American cohorts (5992 biopsies) yielded the PBCG model area under the receiver operating characteristic curve (AUC) as 75.5% (95% confidence interval: 74.2-76.8), a small improvement over the AUC of 72.3% (70.9-73.7) for the PCPTRC (p<0.0001). However, calibration and clinical net benefit were far superior for the PBCG model. Using a risk threshold of 10%, clinical use of the PBCG model would lead to the equivalent of 25 fewer biopsies per 1000 patients without missing any high-grade cancers. Results were similar on external validation on 10 377 European biopsies. The PBCG model should be used in place of the PCPTRC for prediction of prostate biopsy outcome. A contemporary risk tool for outcomes on prostate biopsy based on the routine clinical risk factors is now available for informed decision-making. Copyright

  14. CT-guided transgluteal biopsy for systematic sampling of the prostate in patients without rectal access: a 13-year single-center experience.

    PubMed

    Olson, Michael C; Atwell, Thomas D; Mynderse, Lance A; King, Bernard F; Welch, Timothy; Goenka, Ajit H

    2017-08-01

    The purpose of our study was to examine the safety and diagnostic utility of transgluteal CT-guided prostate biopsy for prostate sampling in patients without rectal access. Seventy-three biopsies were performed in 65 patients over a 13-year period (2002-2015). Mean prostate-specific antigen (PSA) at biopsy was 7.8 ng/mL (range 0.37-31.5). Electronic medical records were reviewed for procedural details and complications. Mean PSA and number of cores in malignant and benign cohorts were compared with Student's t test. Technical success rate was 97.3% (71/73; mean cores 8, range 3-28). Of these, 43.6% (31/71) yielded malignancy (mean Gleason score 7, range 6-10) and 56.3% (40/71) yielded benign tissue. The only complication was an asymptomatic periprostatic hematoma (1/73; 1.4%). In 14 patients who underwent surgery, Gleason scores were concordant in 71.4% (10/14) and discordant in 28.6% (4/14; Gleason 6 on biopsy but Gleason 7 on surgical specimen). Mean effective radiation dose was 18.5 mSv (median 15.0, range 4.4-86.2). There was no significant difference in either mean PSA (p = 0.06) or number of core specimens (p = 0.33) between malignant and benign cohorts. CT-guided transgluteal prostate biopsy is highly safe and reliable for the detection of prostate cancer in men without rectal access. • Prostate cancer detection in men without rectal access is challenging. • CT-guided transgluteal prostate biopsy is safe and effective in these patients. • CT-guided biopsy may be particularly effective in diagnosing high-grade prostate cancer. • Unilateral CT-guided biopsy may be effective in patients with focal lesions. • The radiation exposure with this technique is acceptable.

  15. The reasons behind variation in Gleason grading of prostatic biopsies: areas of agreement and misconception among 266 European pathologists.

    PubMed

    Berney, Daniel M; Algaba, Ferran; Camparo, Philippe; Compérat, Eva; Griffiths, David; Kristiansen, Glen; Lopez-Beltran, Antonio; Montironi, Rodolfo; Varma, Murali; Egevad, Lars

    2014-02-01

    The Gleason scoring system underwent revision at the International Society of Urological Pathology (ISUP) conference in 2005. It is not known how uropathologists have interpreted its recommendations. A web-based survey to European Network of Uropathology members received replies from 266 pathologists in 22 countries. Eighty-nine per cent claimed to follow ISUP recommendations. Key areas of disagreement included the following. Smoothly rounded cribriform glands were assigned Gleason pattern (GP) 3 by 51% and GP 4 by 49%. Necrosis was diagnosed as GP 5 by 62%. Any amount of secondary pattern of higher grade in needle biopsies was included in the Gleason score by 58%. Tertiary GP of higher grade on needle biopsies was included in the Gleason score by only 58%. If biopsy cores were embedded separately, only 56% would give a Gleason score for each core/slide examined; 68% would give a concluding Gleason score and the most common method was a global Gleason score (77%). Among those who blocked multiple biopsy cores together, 46% would only give an overall Gleason score for the case. Misinterpretation of ISUP 2005 is widespread, and may explain the variation in Gleason scoring seen. Clarity and uniformity in teaching ISUP 2005 recommendations is necessary. © 2013 John Wiley & Sons Ltd.

  16. Micro-Photoluminescence (micro-PL) Study of Core-Shell GaAs/GaAsSb Nanowires Grown by Self-Assisted Molecular Beam Epitaxy

    DTIC Science & Technology

    2015-06-18

    public release; distribution is unlimited. Micro-Photoluminescence (micro-PL) Study of Core-Shell GaAs/GaAsSb Nanowires grown by Self-Assisted Molecular...U.S. Army Research Office P.O. Box 12211 Research Triangle Park, NC 27709-2211 GaAsSb, Core Shell Nanowires , Micro Photoluminescence...University 1601 East Market Street Greensboro, NC 27411 -0001 ABSTRACT Micro-Photoluminescence (micro-PL) Study of Core-Shell GaAs/GaAsSb Nanowires grown by

  17. Abdominal wall integrity after open abdomen: long-term results of vacuum-assisted wound closure and mesh-mediated fascial traction (VAWCM).

    PubMed

    Willms, A; Schaaf, S; Schwab, R; Richardsen, I; Bieler, D; Wagner, B; Güsgen, C

    2016-12-01

    The open abdomen has become a standard technique in the management of critically ill patients undergoing surgery for severe intra-abdominal conditions. Negative pressure and mesh-mediated fascial traction are commonly used and achieve low fistula rates and high fascial closure rates. In this study, long-term results of a standardised treatment approach are presented. Fifty-five patients who underwent OA management for different indications at our institution from 2006 to 2013 were enrolled. All patients were treated under a standardised algorithm that uses a combination of vacuum-assisted wound closure and mesh-mediated fascial traction. Structured follow-up assessments were offered to patients and included a medical history, a clinical examination and abdominal ultrasonography. The data obtained were statistically analysed. The fascial closure rate was 74 % in an intention-to-treat analysis and 89 % in a per-protocol analysis. The fistula rate was 1.8 %. Thirty-four patients attended follow-up. The median follow-up was 46 months (range 12-88 months). Incisional hernias developed in 35 %. Patients with hernias needed more operative procedures (10.3 vs 3.4, p = 0.03) than patients without hernia formation. A Patient Observer Scar Assessment Scale (POSAS) of 31.1 was calculated. Patients with symptomatic hernias (NAS of 2-10) had a significantly lower mean POSAS score (p = 0.04). Vacuum-assisted wound closure and mesh-mediated fascial traction (VAWCM) seem to result in low complication rates and high fascial closure rates. Abdominal wall reconstruction, which is a challenging and complex procedure and causes considerable patient discomfort, can thus be avoided in the majority of cases. Available results are based on studies involving only a small number of cases. Multi-centre studies and registry-based data are therefore needed to validate these findings.

  18. Impact of axillary ultrasound and core needle biopsy on the utility of intraoperative frozen section analysis and treatment decision making in women with invasive breast cancer.

    PubMed

    Caretta-Weyer, Holly; Sisney, Gale A; Beckman, Catherine; Burnside, Elizabeth S; Salkowsi, Lonie R; Strigel, Roberta M; Wilke, Lee G; Neuman, Heather B

    2012-09-01

    Our objective was to evaluate the impact of preoperative axillary ultrasound and core needle biopsy (CNB) on breast cancer treatment decision making. A secondary aim was to evaluate the impact on the utility of intraoperative sentinel lymph node (SLN) frozen section. A review of 84 patients with clinically negative axilla who underwent axillary ultrasound was performed. Sensitivity, specificity, and positive/negative predictive value for axillary ultrasound with CNB was calculated. Thirty-one (37%) had suspicious nodes. Of 27 amenable to CNB, 12 (14%) were malignant, changing treatment plans. The sensitivity of ultrasound and CNB was 54% and specificity 100%; the positive and negative predictive values were 100% and 80%, respectively. In 41 patients with normal ultrasounds who underwent SLN frozen section, 10 (24%) were positive. Preoperative axillary ultrasound impacts treatment decision making in 14%. With a sensitivity of 54%, it is a useful adjunct to, but not replacement for, SLN biopsy. Frozen section remains of utility even after a negative axillary ultrasound. Copyright © 2012 Elsevier Inc. All rights reserved.

  19. Optimisation of fluorescence guidance during robot-assisted laparoscopic sentinel node biopsy for prostate cancer.

    PubMed

    KleinJan, Gijs H; van den Berg, Nynke S; Brouwer, Oscar R; de Jong, Jeroen; Acar, Cenk; Wit, Esther M; Vegt, Erik; van der Noort, Vincent; Valdés Olmos, Renato A; van Leeuwen, Fijs W B; van der Poel, Henk G

    2014-12-01

    The hybrid tracer was introduced to complement intraoperative radiotracing towards the sentinel nodes (SNs) with fluorescence guidance. Improve in vivo fluorescence-based SN identification for prostate cancer by optimising hybrid tracer preparation, injection technique, and fluorescence imaging hardware. Forty patients with a Briganti nomogram-based risk >10% of lymph node (LN) metastases were included. After intraprostatic tracer injection, SN mapping was performed (lymphoscintigraphy and single-photon emission computed tomography with computed tomography (SPECT-CT)). In groups 1 and 2, SNs were pursued intraoperatively using a laparoscopic gamma probe followed by fluorescence imaging (FI). In group 3, SNs were initially located via FI. Compared with group 1, in groups 2 and 3, a new tracer formulation was introduced that had a reduced total injected volume (2.0 ml vs. 3.2 ml) but increased particle concentration. For groups 1 and 2, the Tricam SLII with D-Light C laparoscopic FI (LFI) system was used. In group 3, the LFI system was upgraded to an Image 1 HUB HD with D-Light P system. Hybrid tracer-based SN biopsy, extended pelvic lymph node dissection, and robot-assisted radical prostatectomy. Number and location of the preoperatively identified SNs, in vivo fluorescence-based SN identification rate, tumour status of SNs and LNs, postoperative complications, and biochemical recurrence (BCR). Mean fluorescence-based SN identification improved from 63.7% (group 1) to 85.2% and 93.5% for groups 2 and 3, respectively (p=0.012). No differences in postoperative complications were found. BCR occurred in three pN0 patients. Stepwise optimisation of the hybrid tracer formulation and the LFI system led to a significant improvement in fluorescence-assisted SN identification. Preoperative SPECT-CT remained essential for guiding intraoperative SN localisation. Intraoperative fluorescence-based SN visualisation can be improved by enhancing the hybrid tracer formulation and

  20. Penthrox inhaler analgesia in transrectal ultrasound-guided prostate biopsy.

    PubMed

    Lee, Chanyang; Woo, Henry H

    2015-06-01

    Periprostatic injection of local anaesthetic (PILA) has been shown to significantly reduce pain in patients undergoing transrectal ultrasound-guided prostate biopsy (TRUSPB). However, this method does not address pain that is associated with ultrasound probe insertion, and the injection of local anaesthetic itself causes pain. The aim of this study was to explore the efficacy of methoxyflurane delivered by a Penthrox inhaler as a novel method of pain relief during TRUSPB. From July 2012 to July 2013, 64 patients were scheduled at a single centre to undergo TRUSPB while receiving analgesia via Penthrox inhaler. Fifteen minutes after the biopsy procedure, these patients were asked to complete a pain score survey using a 10-cm visual analogue scale (VAS) to separately report the degree of pain experienced during digital rectal examination (DRE), ultrasound probe insertion and core biopsy. The median pain scores on a 10-cm VAS were 2.0, 2.4 and 3.0 during DRE, probe insertion and needle biopsy, respectively, while using the Penthrox inhaler. Of the 64 patients, 11 had undergone TRUSPB previously receiving PILA. In these patients, PILA was significantly better than the Penthrox inhaler for pain relief during needle biopsy (median pain score 2.0 versus 4.0; P = 0.012). The Penthrox inhaler appears to be a safe and effective method of analgesia for TRUSPB. Patients who had experienced both PILA and Penthrox reported pain scores that significantly favoured PILA over the Penthrox inhaler. © 2014 Royal Australasian College of Surgeons.

  1. Optical spectroscopy for stereotactic biopsy of brain tumors

    NASA Astrophysics Data System (ADS)

    Markwardt, Niklas; von Berg, Anna; Fiedler, Sebastian; Goetz, Marcus; Haj-Hosseini, Neda; Polzer, Christoph; Stepp, Herbert; Zelenkov, Petr; Rühm, Adrian

    2015-07-01

    Stereotactic biopsy procedure is performed to obtain a tissue sample for diagnosis purposes. Currently, a fiber-based mechano-optical device for stereotactic biopsies of brain tumors is developed. Two different fluorophores are employed to improve the safety and reliability of this procedure: The fluorescence of intravenously applied indocyanine green (ICG) facilitates the recognition of blood vessels and thus helps minimize the risk of cerebral hemorrhages. 5- aminolevulinic-acid-induced protoporphyrin IX (PpIX) fluorescence is used to localize vital tumor tissue. ICG fluorescence detection using a 2-fiber probe turned out to be an applicable method to recognize blood vessels about 1.5 mm ahead of the fiber tip during a brain tumor biopsy. Moreover, the suitability of two different PpIX excitation wavelengths regarding practical aspects was investigated: While PpIX excitation in the violet region (at 405 nm) allows for higher sensitivity, red excitation (at 633 nm) is noticeably superior with regard to blood layers obscuring the fluorescence signal. Contact measurements on brain simulating agar phantoms demonstrated that a typical blood coverage of the tumor reduces the PpIX signal to about 75% and nearly 0% for 633 nm and 405 nm excitation, respectively. As a result, 633 nm seems to be the wavelength of choice for PpIX-assisted detection of high-grade gliomas in stereotactic biopsy.

  2. Ultrasound-Guided Transcutaneous Needle Biopsy of the Base of the Tongue and Floor of the Mouth From a Submental Approach.

    PubMed

    Wagner, Jason M; Conrad, Rachel D; Cannon, Trinitia Y; Alleman, Anthony M

    2016-05-01

    Limited data exist regarding the feasibility of ultrasound-guided transcutaneous biopsy of the base of the tongue and floor of the mouth. This retrospective study reviewed 8 cases with lesions in the base of the tongue or floor of the mouth that were biopsied by fine-needle aspiration. Core biopsy was also needed in 1 case. All biopsies were technically successful, and all yielded squamous cell carcinoma. One biopsy yielded a false-positive result, as subsequent resection yielded high-grade dysplasia with no invasion. The other biopsy results were considered true-positive based on subsequent pathologic examinations (2 cases) or clinical/imaging follow-up (5 cases). There were no significant complications associated with the biopsies. © 2016 by the American Institute of Ultrasound in Medicine.

  3. Systematic ultrasound-guided saturation and template biopsy of the prostate: indications and advantages of extended sampling.

    PubMed

    Isbarn, Hendrik; Briganti, Alberto; De Visschere, Pieter J L; Fütterer, Jurgen J; Ghadjar, Pirus; Giannarini, Gianluca; Ost, Piet; Ploussard, Guillaume; Sooriakumaran, Prasanna; Surcel, Christian I; van Oort, Inge M; Yossepowitch, Ofer; van den Bergh, Roderick C N

    2015-04-01

    Prostate biopsy (PB) is the gold standard for the diagnosis of prostate cancer (PCa). However, the optimal number of biopsy cores remains debatable. We sought to compare contemporary standard (10-12 cores) vs. saturation (=18 cores) schemes on initial as well as repeat PB. A non-systematic review of the literature was performed from 2000 through 2013. Studies of highest evidence (randomized controlled trials, prospective non-randomized studies, and retrospective reports of high quality) comparing standard vs saturation schemes on initial and repeat PB were evaluated. Outcome measures were overall PCa detection rate, detection rate of insignificant PCa, and procedure-associated morbidity. On initial PB, there is growing evidence that a saturation scheme is associated with a higher PCa detection rate compared to a standard one in men with lower PSA levels (<10 ng/ml), larger prostates (>40 cc), or lower PSA density values (<0.25 ng/ml/cc). However, these cut-offs are not uniform and differ among studies. Detection rates of insignificant PCa do not differ in a significant fashion between standard and saturation biopsies. On repeat PB, PCa detection rate is likewise higher with saturation protocols. Estimates of insignificant PCa vary widely due to differing definitions of insignificant disease. However, the rates of insignificant PCa appear to be comparable for the schemes in patients with only one prior negative biopsy, while saturation biopsy seems to detect more cases of insignificant PCa compared to standard biopsy in men with two or more prior negative biopsies. Very extensive sampling is associated with a high rate of acute urinary retention, whereas other severe adverse events, such as sepsis, appear not to occur more frequently with saturation schemes. Current evidence suggests that saturation schemes are associated with a higher PCa detection rate compared to standard ones on initial PB in men with lower PSA levels or larger prostates, and on repeat PB. Since

  4. CT-Guided Biopsy of Small Liver Lesions: Visibility, Artifacts, and Corresponding Diagnostic Accuracy

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Stattaus, Joerg, E-mail: joerg.stattaus@uni-due.de; Kuehl, Hilmar; Ladd, Susanne

    2007-09-15

    Purpose. Our study aimed to determine the visibility of small liver lesions during CT-guided biopsy and to assess the influence of lesion visibility on biopsy results. Material and Methods. Fifty patients underwent CT-guided core biopsy of small focal liver lesions (maximum diameter, 3 cm); 38 biopsies were performed using noncontrast CT, and the remaining 12 were contrast-enhanced. Visibility of all lesions was graded on a 4-point-scale (0 = not visible, 1 = poorly visible, 2 = sufficiently visible, 3 = excellently visible) before and during biopsy (with the needle placed adjacent to and within the target lesion). Results. Forty-three biopsiesmore » (86%) yielded diagnostic results, and seven biopsies were false-negative. In noncontrast biopsies, the rate of insufficiently visualized lesions (grades 0-1) increased significantly during the procedure, from 10.5% to 44.7%, due to needle artifacts. This resulted in more (17.6%) false-negative biopsy results compared to lesions with good visualization (4.8%), although this difference lacks statistical significance. Visualization impairment appeared more often with an intercostal or subcostal vs. an epigastric access and with a subcapsular vs. a central lesion location, respectively. With contrast-enhanced biopsy the visibility of hepatic lesions was only temporarily improved, with a risk of complete obscuration in the late phase. Conclusion. In conclusion, visibility of small liver lesions diminished significantly during CT-guided biopsy due to needle artifacts, with a fourfold increased rate of insufficiently visualized lesions and of false-negative histological results. Contrast enhancement did not reveal better results.« less

  5. Comparison of tumor-infiltrating lymphocytes of breast cancer in core needle biopsies and resected specimens: a retrospective analysis.

    PubMed

    Cha, Yoon Jin; Ahn, Sung Gwe; Bae, Soong June; Yoon, Chang Ik; Seo, Jayeong; Jung, Woo Hee; Son, Eun Ju; Jeong, Joon

    2018-06-05

    Neoadjuvant chemotherapy (NAC) is being increasingly used to treat locally advanced breast cancer and to conserve the breast. In triple-negative breast cancer and HER2-positive breast cancer, a high density of tumor-infiltrating lymphocytes (TILs) is an important predictor of NAC response. Thus far, it remains unclear whether the TIL scores in core needle biopsies (CNBs) are closely representative of those in the whole tumor section in resected specimens. This study aimed to evaluate the concordance between the TIL scores of CNBs and resected specimens of breast cancer. A total of 220 matched pairs of CNBs and resected specimens of breast cancer were included. Stromal TILs were scored on slides stained with hematoxylin and eosin. Clinicopathologic parameters and the agreement of the TIL scores between CNBs and resected specimens were statistically analyzed. The average TIL score was approximately 4.4% higher for the resected specimens than for the CNBs. When the tumors were divided into two groups according to a 60% TIL score cut-off (low and intermediate TIL vs. high TIL), 8.2% showed discordance between the CNB and resected specimen. The overall intraclass correlation coefficient (ICC) value of the TIL score was 0.895 (95% confidence interval, 0.864-0.920, P < 0.001), and all molecular subtypes showed ICC values over 0.8 (P < 0.001). The ICC values were > 0.9 when ≥ 5 cores were included in the CNBs. Tumors with discordant TILs were characterized by histologic grade III, ER negativity, high proliferative index, and HER2 and triple-negative subtypes. A high proliferative index was an independent risk factor for TIL discordance. The TIL score in CNB specimens is a reliable value that reflects the TIL status of the entire tumor in resected specimens of breast cancer. More than five CNB cores may accurately predict the TIL score of the entire tumor.

  6. Comparative Effectiveness of Targeted Prostate Biopsy Using Magnetic Resonance Imaging Ultrasound Fusion Software and Visual Targeting: a Prospective Study.

    PubMed

    Lee, Daniel J; Recabal, Pedro; Sjoberg, Daniel D; Thong, Alan; Lee, Justin K; Eastham, James A; Scardino, Peter T; Vargas, Hebert Alberto; Coleman, Jonathan; Ehdaie, Behfar

    2016-09-01

    We compared the diagnostic outcomes of magnetic resonance-ultrasound fusion and visually targeted biopsy for targeting regions of interest on prostate multiparametric magnetic resonance imaging. Patients presenting for prostate biopsy with regions of interest on multiparametric magnetic resonance imaging underwent magnetic resonance imaging targeted biopsy. For each region of interest 2 visually targeted cores were obtained, followed by 2 cores using a magnetic resonance-ultrasound fusion device. Our primary end point was the difference in the detection of high grade (Gleason 7 or greater) and any grade cancer between visually targeted and magnetic resonance-ultrasound fusion, investigated using McNemar's method. Secondary end points were the difference in detection rate by biopsy location using a logistic regression model and the difference in median cancer length using the Wilcoxon signed rank test. We identified 396 regions of interest in 286 men. The difference in the detection of high grade cancer between magnetic resonance-ultrasound fusion biopsy and visually targeted biopsy was -1.4% (95% CI -6.4 to 3.6, p=0.6) and for any grade cancer the difference was 3.5% (95% CI -1.9 to 8.9, p=0.2). Median cancer length detected by magnetic resonance-ultrasound fusion and visually targeted biopsy was 5.5 vs 5.8 mm, respectively (p=0.8). Magnetic resonance-ultrasound fusion biopsy detected 15% more cancers in the transition zone (p=0.046) and visually targeted biopsy detected 11% more high grade cancer at the prostate base (p=0.005). Only 52% of all high grade cancers were detected by both techniques. We found no evidence of a significant difference in the detection of high grade or any grade cancer between visually targeted and magnetic resonance-ultrasound fusion biopsy. However, the performance of each technique varied in specific biopsy locations and the outcomes of both techniques were complementary. Combining visually targeted biopsy and magnetic resonance

  7. A Comparison of Four- Versus Three-Pass Transjugular Biopsy Using a 19-G Tru-Cut Needle and a Randomized Study Using a Cassette to Prevent Biopsy Fragmentation

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Vibhakorn, Shusang; Cholongitas, Evangelos; Kalambokis, George

    2009-05-15

    Recently, it has been shown that transjugular liver biopsy (TJLB) with three passes gives comparable specimens to percutaneous liver biopsy (PLB). The aim of this study was to evaluate the adequacy of TJLB using four passes in a consecutive series of patients, and whether using a supportive cassette can prevent fragmentation. One hundred consecutive TJLBs in 92 patients (48 transplanted), always using four passes (19-G Tru-Cut), were compared to three-pass TJLBs. The four-pass TJLB specimens were randomized at a 1:1 ratio of liver cores placed in a cassette versus not. The four-pass TJLBs, compared to three-pass TJLBs, resulted in bettermore » specimens for length ({>=}25 mm: 50% vs. 35%; p = 0.026) and number of complete portal tracts (CPTs) ({>=}11: 40% vs. 26%; p = 0.027), without a higher complication rate. The four-pass TJLB with {>=}11 CPTs had a median length of 27 mm, and 57% of them longer than 28 mm contained {>=}11 CPTs. Putting the liver biopsy cores into a cassette did not improve the fragmentation rate or adequacy of the specimen (length and number of CPTs) of TJLB. We conclude that at least four passes with TJLB should be performed when liver specimens are needed for grading and staging. Using a supportive cassette did not reduce fragmentation.« less

  8. Forward kinematic analysis of in-vivo robot for stomach biopsy.

    PubMed

    Sutar, Mihir Kumar; Pathak, P M; Sharma, A K; Mehta, N K; Gupta, V K

    2013-09-01

    The introduction of robotic medical assistance in biopsy and stomach cavity exploration is one of the most important milestones in the field of medical science. The research is still in its infancy and many issues like limitations in dexterity, control, and abdominal cavity vision are the main concerns of many researchers around the globe. This paper presents the design aspects and the kinematic analysis of a 4 degrees of freedom (DOF) hyper-redundant in-vivo robot for stomach biopsy. The proposed robot will be inserted through the tool channel of a conventional 4-DOF endoscope and this will increase the dexterity and ease in reaching the furthest parts of the stomach beyond the duodenum. Unlike the traditional biopsy tool, the present design will enhance dexterity due to its 4 DOF in addition to the endoscope's DOF. The endoscope will be positioned at the entrance to the stomach in the esophagus and the robot will move to the desired position inside the stomach for biopsy and exploration. The current robot is wire-actuated and possesses better maneuverability. The forward kinematic analysis of the proposed robot is presented in this paper.

  9. Breast cancer: determining the genetic profile from ultrasound-guided percutaneous biopsy specimens obtained during the diagnostic workups.

    PubMed

    López Ruiz, J A; Zabalza Estévez, I; Mieza Arana, J A

    2016-01-01

    To evaluate the possibility of determining the genetic profile of primary malignant tumors of the breast from specimens obtained by ultrasound-guided percutaneous biopsies during the diagnostic imaging workup. This is a retrospective study in 13 consecutive patients diagnosed with invasive breast cancer by B-mode ultrasound-guided 12 G core needle biopsy. After clinical indication, the pathologist decided whether the paraffin block specimens seemed suitable (on the basis of tumor size, validity of the sample, and percentage of tumor cells) before sending them for genetic analysis with the MammaPrint® platform. The size of the tumors on ultrasound ranged from 0.6cm to 5cm. In 11 patients the preserved specimen was considered valid and suitable for use in determining the genetic profile. In 1 patient (with a 1cm tumor) the pathologist decided that it was necessary to repeat the core biopsy to obtain additional samples. In 1 patient (with a 5cm tumor) the specimen was not considered valid by the genetic laboratory. The percentage of tumor cells in the samples ranged from 60% to 70%. In 11/13 cases (84.62%) it was possible to do the genetic analysis on the previously diagnosed samples. In most cases, regardless of tumor size, it is possible to obtain the genetic profile from tissue specimens obtained with ultrasound-guided 12 G core biopsy preserved in paraffin blocks. Copyright © 2015 SERAM. Published by Elsevier España, S.L.U. All rights reserved.

  10. Diagnostic Accuracy of Multiparametric Magnetic Resonance Imaging and Fusion Guided Targeted Biopsy Evaluated by Transperineal Template Saturation Prostate Biopsy for the Detection and Characterization of Prostate Cancer.

    PubMed

    Mortezavi, Ashkan; Märzendorfer, Olivia; Donati, Olivio F; Rizzi, Gianluca; Rupp, Niels J; Wettstein, Marian S; Gross, Oliver; Sulser, Tullio; Hermanns, Thomas; Eberli, Daniel

    2018-02-21

    We evaluated the diagnostic accuracy of multiparametric magnetic resonance imaging and multiparametric magnetic resonance imaging/transrectal ultrasound fusion guided targeted biopsy against that of transperineal template saturation prostate biopsy to detect prostate cancer. We retrospectively analyzed the records of 415 men who consecutively presented for prostate biopsy between November 2014 and September 2016 at our tertiary care center. Multiparametric magnetic resonance imaging was performed using a 3 Tesla device without an endorectal coil, followed by transperineal template saturation prostate biopsy with the BiopSee® fusion system. Additional fusion guided targeted biopsy was done in men with a suspicious lesion on multiparametric magnetic resonance imaging, defined as Likert score 3 to 5. Any Gleason pattern 4 or greater was defined as clinically significant prostate cancer. The detection rates of multiparametric magnetic resonance imaging and fusion guided targeted biopsy were compared with the detection rate of transperineal template saturation prostate biopsy using the McNemar test. We obtained a median of 40 (range 30 to 55) and 3 (range 2 to 4) transperineal template saturation prostate biopsy and fusion guided targeted biopsy cores, respectively. Of the 124 patients (29.9%) without a suspicious lesion on multiparametric magnetic resonance imaging 32 (25.8%) were found to have clinically significant prostate cancer on transperineal template saturation prostate biopsy. Of the 291 patients (70.1%) with a Likert score of 3 to 5 clinically significant prostate cancer was detected in 129 (44.3%) by multiparametric magnetic resonance imaging fusion guided targeted biopsy, in 176 (60.5%) by transperineal template saturation prostate biopsy and in 187 (64.3%) by the combined approach. Overall 58 cases (19.9%) of clinically significant prostate cancer would have been missed if fusion guided targeted biopsy had been performed exclusively. The sensitivity of

  11. A Vacuum in Political and Economic Labor Policy?

    ERIC Educational Resources Information Center

    Karasek, Robert A.

    2004-01-01

    A vacuum is arising in the social policy of advanced countries. It is due to the fact that both of the currently dominant bases for social policy, market-oriented policy, and its presumed antagonist, welfare state policy, have the same and an insufficiently broad production value model at their core. The solution is to create a true new…

  12. Positional calibration of an ultrasound image-guided robotic breast biopsy system.

    PubMed

    Nelson, Thomas R; Tran, Amy; Fakourfar, Hourieh; Nebeker, Jakob

    2012-03-01

    Precision biopsy of small lesions is essential in providing high-quality patient diagnosis and management. Localization depends on high-quality imaging. We have developed a dedicated, fully automatic volume breast ultrasound (US) imaging system for early breast cancer detection. This work focuses on development of an image-guided robotic biopsy system that is integrated with the volume breast US system for performing minimally invasive breast biopsies. The objective of this work was to assess the positional accuracy of the robotic system for breast biopsy. We have adapted a compact robotic arm for performing breast biopsy. The arm incorporates a force torque sensor and is modified to accommodate breast biopsy sampling needles mounted on the robot end effector. Volume breast US images are used as input to a targeting algorithm that provides the physician with control of biopsy device guidance and trajectory optimization. In this work, the positional accuracy was evaluated using (1) a light-emitting diode (LED) mounted on the end effector and (2) a LED mounted on the end of a biopsy needle, each of which was imaged for each robot controller position as part of mapping the positional accuracy throughout a volume that would contain the breast. We measured the error in each location and the cumulative error. Robotic device performance over the volume provided mean accuracy ± SD of 0.76 ± 0.13 mm (end effector) and 0.55 ± 0.13 mm (needle sample location), sufficient for a targeting accuracy within ±1 mm, which is suitable for clinical use. Depth positioning error also was small: 0.38 ± 0.03 mm. Reproducibility was excellent with less than 0.5% variation. Overall accuracy and reproducibility of the compact robotic device were excellent, well within clinical biopsy performance requirements. Volume breast US data provide high-quality input to a biopsy sampling algorithm under physician control. Robotic devices may provide more precise device placement, assisting

  13. Liquid biopsy: A potential and promising diagnostic tool for advanced stage non-small cell lung cancer patients.

    PubMed

    Doval, D C; Deshpande, R; Dhabhar, B; Babu, K G; Prabhash, K; Chopra, R; Sripada, P V; Deshmukh, C; Suryavanshi, M

    2017-12-01

    More than 50% of non-small cell lung cancer (NSCLC) cases harbor an actionable mutation, and molecular testing at different intervals can help in personalized and targeted treatment. Core tissue biopsy and needle biopsy done at the time of diagnosis/disease progression are interventional, time-consuming and can affect the patients adversely. Noninterventional biomarker testing by liquid biopsy promises to revolutionize advanced stage cancer screening. The present report was formulated based on an expert panel meeting of renowned oncologists who gave their opinions for minimally invasive liquid biopsy to detect targetable molecular biomarkers in advanced NSCLC cases. An exhaustive literature search was done to support their recommendations. Clinical utility of minimally invasive liquid biopsy, for detection of molecular biomarkers in advanced stage NSCLC patients, was broadly discussed by the key opinion leaders.

  14. Use of individual containers for prostate biopsy samples: Do we gain diagnostic performance?

    PubMed

    Panach-Navarrete, J; García-Morata, F; Valls-González, L; Martínez-Jabaloyas, J M

    2016-05-01

    Prostate cores from transrectal biopsies are usually sent in separate vials for pathological processing. Although this is a common practice, there are controversial studies on its usefulness. We wanted to compare the rate of prostate cancer diagnosis between processing samples in 2 containers and processing them in individual containers to see if there are differences. Our secondary objective was to check the rate of diagnosis of various tumour subtypes in each of the 2 groups. A retrospective observational study was conducted of 2,601 cases of prostate biopsies. Ten cores were extracted in each biopsy. We divided the sample into 2 groups: biopsies sent in 2 containers to the department of pathology (left and right lobes) or sent in 10 (one for each cylinder), according to the different criteria used in our centre in the past. We then classified the cases according to the absence of neoplasia, insignificant tumour (involvement of just 1 cylinder, <5%, Gleason score<7), Gleason 6 or Gleason≥7. A bivariate statistical analysis was performed using the chi-squared test. A total of 1,777 participants were included in the 2-container group, and 824 were included in the 10-container group. We diagnosed a rate of 32.4% of cancers in the 2-container group and 40% in the 10-container group, a difference that was statistically significant (P<.001). The insignificant carcinomas were diagnosed more often in the 2-container group than in the 10-container group (6.4% vs. 4.3%, respectively; P=.03). Samples with a Gleason score of 6 were diagnosed more often in the 10-container group than in the 2-container group (11.9% vs. 8.1%, respectively; P=.002). The same occurred with the Gleason score≥7 (23.8% in the 10-container group vs. 17.9% in the 2-container group; P<.001). We diagnosed more prostate cancers when sending biopsied cores in individual containers. Once the procedure was conducted, we also observed in our series a reduction in the diagnoses of insignificant carcinoma

  15. The eternal enigma in prostatic biopsy access route.

    PubMed

    Fabiani, Andrea; Principi, Emanuele; Filosa, Alessandra; Servi, Lucilla

    2017-10-03

    Dear Editors,We read with interest the article by Di Franco and co-workers (1). The introduction of prostatic magnetic resonance and the relative fusion-biopsy have not yet allowed the expected improvements in prostate biopsy. To our knowledge, there are no works that demonstrate the superiority of fusion techniques on the remaining ultrasound guided prostate biopsies that are still the widely used in the diagnosis of prostate cancer. Furthemore, these technologies are expensive exams and they are not yet available in all centers, especially in those minors. We work at a "minor" center and we always keep in mind that the goal of  prostatic biopsy is the diagnosis and the staging of prostatic neoplasms.. However, it remains uncertain which of the two techniques, transperineal (TP) or transrectal (TR), is superior in terms of detection rate during first biopsy setting. Several studies have compared the prostate cancer detection rate but TR and TP access route in prostatic gland sampling seems to be equivalent in terms of efficiency and complications, as reported by Shen PF et al. (2), despite several methodological limitations recognized in their work. The results reported by Di Franco CA et al. represent the real life experience of most urologists that perform the PB based on their own training experience and available technical devices. From an historical viewpoint, the TP route has been the first one to be used to reach the prostate, both for diagnostic and therapeutic purposes. To date, because it seems to be more invasive and difficult, the TP route is less used worldwide than the TR one (2). Theoretically, the TP approach should detect more prostate cancer than the TR way  because the cores of the TP approach are directed longitudinally to the peripheral zone and the anterior part of the prostate (4). The results reported by Di Franco et al. seems to confirm these considerations. However, our real life experience differ from the conclusions reached in their

  16. [Application research of presacral space drainage tube combined with subcutaneous vacuum pressure suction in the laparoscopic-assisted abdominoperineal resection].

    PubMed

    Chen, Liqi; Zeng, Changqing; Chi, Liangjie; Huang, Liangxiang; Li, Jiandang

    2017-08-25

    To study the management for the perineal incision after laparoscopic-assisted abdominoperineal resection for rectal cancer. Clinical data of 87 patients undergoing laparoscopic Miles operation for lower rectal cancer from June 2009 to February 2014 were collected and studied. Presacral space drainage group: presacral space drainage tube was applied in 42 patients. Combined drainage group: presacral space drainage tube combined with subcutaneous vacuum pressure suction was applied in 45 cases. In combined drainage group, except the presacral drainage tube, another drainage tube was placed subcutaneously and connected to a negative pressure ball, which was fixed on the lateral anterior of perineal wound by the further incision and drainage. After subcutaneous tube was placed for 2 weeks, as drainage fluid was limpid and <15 ml/d for 3 days, meanwhile no obvious pelvic fluid was detected by ultrasound, and the wound healed quite well without redness and edema, then the subcutaneous tube with the negative pressure ball could be removed. There were 51 males and 36 females with the mean age of 26-78(56.9±10.8) years old. The laparoscopic Miles operation was successfully completed in all the cases without death and complications. The drainage tube was placed for 4-13(8.0±2.5) days in presacral space drainage group, and for 4-14(6.7±2.4) days in combined drainage group. The subcutaneous tube was placed for 14-24(15.8±3.0) days. The primary healing rate of perineal wound in presacral space drainage group and combined drainage group was 66.7%(28/42) and 91.1%(41/45) respectively, while the perineal wound infection rate was 21.4%(9/42) and 4.4%(2/45) respectively, whose differences between two groups were both significant (χ 2 =7.911, P=0.005 and χ 2 =5.674, P=0.017). Presacral space drainage tube combined with subcutaneous vacuum pressure suction in laparoscopic-assisted abdominoperineal resection for rectal cancer has better efficacy and lower infection rate for

  17. High-resolution rapid diagnostic imaging of whole prostate biopsies using video-rate fluorescence structured illumination microscopy

    PubMed Central

    Wang, Mei; Kimbrell, Hillary Z.; Sholl, Andrew B.; Tulman, David B.; Elfer, Katherine N.; Schlichenmeyer, Tyler C.; Lee, Benjamin R.; Lacey, Michelle; Brown, J. Quincy

    2015-01-01

    Rapid assessment of prostate core biopsy pathology at the point-of-procedure could provide benefit in a variety of clinical situations. Even with advanced trans-rectal ultrasound guidance and saturation biopsy protocols, prostate cancer can be missed in up to half of all initial biopsy procedures. In addition, collection of tumor specimens for downstream histological, molecular, and genetic analysis is hindered by low tumor yield due to inability to identify prostate cancer grossly. However, current point-of-procedure pathology protocols such as frozen section analysis (FSA) are destructive, and too time- and labor-intensive to be practical or economical. Ex vivo microscopy of the excised specimens, stained with fast-acting fluorescent histology dyes, could be an attractive non-destructive alternative to FSA. In this work, we report the first demonstration of video-rate structured illumination microscopy (VR-SIM) for rapid high-resolution diagnostic imaging of prostate biopsies in realistic point-of-procedure timeframes. Large mosaic images of prostate biopsies stained with acridine orange are rendered in seconds, and contain excellent contrast and detail, exhibiting close correlation with corresponding H&E histology. A clinically-relevant review of VR-SIM images of 34 unfixed and uncut prostate core biopsies by two independent pathologists resulted in an area under the ROC curve (AUC) of 0.82–0.88, with a sensitivity ranging from 63–88% and a specificity ranging from 78–89%. When biopsies contained more than 5% tumor content, the sensitivity improved to 75–92%. The image quality, speed, minimal complexity, and ease of use of VR-SIM could prove to be features in favor of adoption as an alternative to destructive pathology at the point-of-procedure. PMID:26282168

  18. Bone lesion biopsy

    MedlinePlus

    Bone biopsy; Biopsy - bone ... the cut, then pushed and twisted into the bone. Once the sample is obtained, the needle is ... sample is sent to a lab for examination. Bone biopsy may also be done under general anesthesia ...

  19. Ureteral retrograde brush biopsy

    MedlinePlus

    Biopsy - brush - urinary tract; Retrograde ureteral brush biopsy cytology; Cytology - ureteral retrograde brush biopsy ... should not be performed in people with a: Urinary tract infection Blockage at or below the biopsy site ...

  20. Open lung biopsy

    MedlinePlus

    Biopsy - open lung ... An open lung biopsy is done in the hospital using general anesthesia . This means you will be asleep and ... The open lung biopsy is done to evaluate lung problems seen on x-ray or CT scan .

  1. Histologic Subtype in Core Lung Biopsies of Early-Stage Lung Adenocarcinoma is a Prognostic Factor for Treatment Response and Failure Patterns After Stereotactic Body Radiation Therapy

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Leeman, Jonathan E.; Rimner, Andreas; Montecalvo, Joseph

    Purpose: Stereotactic body radiation therapy (SBRT) has emerged as an effective treatment for early-stage lung cancer. The histologic subtype of surgically resected lung adenocarcinoma is recognized as a prognostic factor, with the presence of solid or micropapillary patterns predicting poor outcomes. We describe the outcomes after SBRT for early-stage lung adenocarcinoma stratified by histologic subtype. Methods and Materials: We identified 119 consecutive patients (124 lesions) with stage I to IIA lung adenocarcinoma who had undergone definitive SBRT at our institution from August 2008 to August 2015 and had undergone core biopsy. Histologic subtyping was performed according to the 2015 Worldmore » Health Organization classification. Of the 124 tumors, 37 (30%) were a high-risk subtype, defined as containing a component of solid and/or micropapillary pattern. The cumulative incidences of local, nodal, regional, and distant failure were compared between the high-risk and non–high-risk adenocarcinoma subtypes using Gray's test, and multivariable-adjusted hazard ratios (HRs) were estimated from propensity score–weighted Cox regression models. Results: The median follow-up for the entire cohort was 17 months and for surviving patients was 21 months. The 1-year cumulative incidence of and adjusted HR for local, nodal, regional, and distant failure in high-risk versus non–high-risk lesions was 7.3% versus 2.7% (HR 16.8; 95% confidence interval [CI] 3.5-81.4), 14.8% versus 2.6% (HR 3.8; 95% CI 0.95-15.0), 4.0% versus 1.2% (HR 20.9; 95% CI 2.3-192.3), and 22.7% versus 3.6% (HR 6.9; 95% CI 2.2-21.1), respectively. No significant difference was seen with regard to overall survival. Conclusions: The outcomes after SBRT for early-stage adenocarcinoma of the lung correlate highly with histologic subtype, with micropapillary and solid tumors portending significantly higher rates of locoregional and metastatic progression. In this context, the histologic subtype

  2. Histologic Subtype in Core Lung Biopsies of Early-Stage Lung Adenocarcinoma is a Prognostic Factor for Treatment Response and Failure Patterns After Stereotactic Body Radiation Therapy.

    PubMed

    Leeman, Jonathan E; Rimner, Andreas; Montecalvo, Joseph; Hsu, Meier; Zhang, Zhigang; von Reibnitz, Donata; Panchoo, Kelly; Yorke, Ellen; Adusumilli, Prasad S; Travis, William; Wu, Abraham J

    2017-01-01

    Stereotactic body radiation therapy (SBRT) has emerged as an effective treatment for early-stage lung cancer. The histologic subtype of surgically resected lung adenocarcinoma is recognized as a prognostic factor, with the presence of solid or micropapillary patterns predicting poor outcomes. We describe the outcomes after SBRT for early-stage lung adenocarcinoma stratified by histologic subtype. We identified 119 consecutive patients (124 lesions) with stage I to IIA lung adenocarcinoma who had undergone definitive SBRT at our institution from August 2008 to August 2015 and had undergone core biopsy. Histologic subtyping was performed according to the 2015 World Health Organization classification. Of the 124 tumors, 37 (30%) were a high-risk subtype, defined as containing a component of solid and/or micropapillary pattern. The cumulative incidences of local, nodal, regional, and distant failure were compared between the high-risk and non-high-risk adenocarcinoma subtypes using Gray's test, and multivariable-adjusted hazard ratios (HRs) were estimated from propensity score-weighted Cox regression models. The median follow-up for the entire cohort was 17 months and for surviving patients was 21 months. The 1-year cumulative incidence of and adjusted HR for local, nodal, regional, and distant failure in high-risk versus non-high-risk lesions was 7.3% versus 2.7% (HR 16.8; 95% confidence interval [CI] 3.5-81.4), 14.8% versus 2.6% (HR 3.8; 95% CI 0.95-15.0), 4.0% versus 1.2% (HR 20.9; 95% CI 2.3-192.3), and 22.7% versus 3.6% (HR 6.9; 95% CI 2.2-21.1), respectively. No significant difference was seen with regard to overall survival. The outcomes after SBRT for early-stage adenocarcinoma of the lung correlate highly with histologic subtype, with micropapillary and solid tumors portending significantly higher rates of locoregional and metastatic progression. In this context, the histologic subtype determined from core biopsies is a prognostic factor and could have

  3. Oropharynx lesion biopsy

    MedlinePlus

    ... Mouth lesion biopsy; Oral cancer - biopsy Images Throat anatomy Oropharyngeal biopsy References Lee FE-H, Treanor JJ. Viral infections. In: Broaddus VC, Mason RJ, Ernst JD, et al, eds. Murray & Nadel's Textbook of Respiratory Medicine . 6th ed. Philadelphia, PA: Elsevier ...

  4. Therapeutic strategy for granulomatous lobular mastitis: a clinicopathological study of 12 patients.

    PubMed

    Akahane, Kazuhisa; Tsunoda, Nobuyuki; Kato, Masamichi; Noda, Sumiyo; Shimoyama, Yoshie; Ishigakis, Satoko; Satake, Hiroko; Nakamura, Shigeo; Nagino, Masato

    2013-08-01

    Granulomatous lobular mastitis (GLM) is a rare inflammatory pseudotumor. No therapeutic modality for this disease has been established because of its rarity. The purpose of this study is to evaluate the treatment strategies of GLM. Twelve women who met the histological criteria for GLM were retrospectively studied. The clinical data and the presentation, histopathology, and management of the disease were analyzed by reviewing the patients' medical records. The diagnosis of GLM was confirmed histologically by core needle biopsy in 9 cases, by vacuum-assisted biopsy in 2 cases, and by excisional biopsy in 1 case. Ten patients received corticosteroid treatment and another two patients were treated with local excision or incision and drainage. The median initial dosage of corticosteroid (Prednisolone) was 30 mg/day (range: 15-60 mg/day), and the dosages were tapered according to improvement. The median duration of corticosteroid treatment was 5 months (range: 1-12 months). The median follow-up period was 22 months (range: 6-104 months), and no patient treated with corticosteroid demonstrated recurrence. However, patients treated with excision or incision and drainage had recurrences. These results suggest that steroid treatment may be the first choice in treatment strategies for GLM.

  5. First International Consensus Conference on lesions of uncertain malignant potential in the breast (B3 lesions).

    PubMed

    Rageth, Christoph J; O'Flynn, Elizabeth Am; Comstock, Christopher; Kurtz, Claudia; Kubik, Rahel; Madjar, Helmut; Lepori, Domenico; Kampmann, Gert; Mundinger, Alexander; Baege, Astrid; Decker, Thomas; Hosch, Stefanie; Tausch, Christoph; Delaloye, Jean-François; Morris, Elisabeth; Varga, Zsuzsanna

    2016-09-01

    The purpose of this study is to obtain a consensus for the therapy of B3 lesions. The first International Consensus Conference on lesions of uncertain malignant potential in the breast (B3 lesions) including atypical ductal hyperplasia (ADH), flat epithelial atypia (FEA), classical lobular neoplasia (LN), papillary lesions (PL), benign phyllodes tumors (PT), and radial scars (RS) took place in January 2016 in Zurich, Switzerland organized by the International Breast Ultrasound School and the Swiss Minimally Invasive Breast Biopsy group-a subgroup of the Swiss Society of Senology. Consensus recommendations for the management and follow-up surveillance of these B3 lesions were developed and areas of research priorities were identified. The consensus recommendation for FEA, LN, PL, and RS diagnosed on core needle biopsy or vacuum-assisted biopsy (VAB) is to therapeutically excise the lesion seen on imaging by VAB and no longer by open surgery, with follow-up surveillance imaging for 5 years. The consensus recommendation for ADH and PT is, with some exceptions, therapeutic first-line open surgical excision. Minimally invasive management of selected B3 lesions with therapeutic VAB is acceptable as an alternative to first-line surgical excision.

  6. A vacuum microgripping tool with integrated vibration releasing capability

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Rong, Weibin; Fan, Zenghua, E-mail: zenghua-fan@163.com; Wang, Lefeng

    2014-08-01

    Pick-and-place of micro-objects is a basic task in various micromanipulation demands. Reliable releasing of micro-objects is usually disturbed due to strong scale effects. This paper focuses on a vacuum micro-gripper with vibration releasing functionality, which was designed and assembled for reliable micromanipulation tasks. Accordingly, a vibration releasing strategy of implementing a piezoelectric actuator on the vacuum microgripping tool is presented to address the releasing problem. The releasing mechanism was illustrated using a dynamic micro contact model. This model was developed via theoretical analysis, simulations and pull-off force measurement using atomic force microscopy. Micromanipulation experiments were conducted to verify the performancemore » of the vacuum micro-gripper. The results show that, with the assistance of the vibration releasing, the vacuum microgripping tool can achieve reliable release of micro-objects. A releasing location accuracy of 4.5±0.5 μm and a successful releasing rate of around 100% (which is based on 110 trials) were achieved for manipulating polystyrene microspheres with radius of 35–100 μm.« less

  7. Using the epigenetic field defect to detect prostate cancer in biopsy negative patients.

    PubMed

    Truong, Matthew; Yang, Bing; Livermore, Andrew; Wagner, Jennifer; Weeratunga, Puspha; Huang, Wei; Dhir, Rajiv; Nelson, Joel; Lin, Daniel W; Jarrard, David F

    2013-06-01

    We determined whether a novel combination of field defect DNA methylation markers could predict the presence of prostate cancer using histologically normal transrectal ultrasound guided biopsy cores. Methylation was assessed using quantitative Pyrosequencing® in a training set consisting of 65 nontumor and tumor associated prostate tissues from University of Wisconsin. A multiplex model was generated using multivariate logistic regression and externally validated in blinded fashion in a set of 47 nontumor and tumor associated biopsy specimens from University of Washington. We observed robust methylation differences in all genes at all CpGs assayed (p <0.0001). Regression models incorporating individual genes (EVX1, CAV1 and FGF1) and a gene combination (EVX1 and FGF1) discriminated nontumor from tumor associated tissues in the original training set (AUC 0.796-0.898, p <0.001). On external validation uniplex models incorporating EVX1, CAV1 or FGF1 discriminated tumor from nontumor associated biopsy negative specimens (AUC 0.702, 0.696 and 0.658, respectively, p <0.05). A multiplex model (EVX1 and FGF1) identified patients with prostate cancer (AUC 0.774, p = 0.001) and had a negative predictive value of 0.909. Comparison between 2 separate cores in patients in this validation set revealed similar methylation defects, indicating detection of a widespread field defect. A widespread epigenetic field defect can be used to detect prostate cancer in patients with histologically negative biopsies. To our knowledge this assay is unique, in that it detects alterations in nontumor cells. With further validation this marker combination (EVX1 and FGF1) has the potential to decrease the need for repeat prostate biopsies, a procedure associated with cost and complications. Copyright © 2013 American Urological Association Education and Research, Inc. Published by Elsevier Inc. All rights reserved.

  8. Male breast cancer is rare: an initial presentation may be as an abscess

    PubMed Central

    Ventham, N T; Hussien, M I

    2010-01-01

    Breast cancer in men is rare. Breast cancer presenting initially as an abscess has been described only a handful of times in the literature. We present the first described case of invasive adenocarcinoma presenting as an abscess in a man. An 80-year-old diabetic man presented with symptoms typical of a breast abscess. The abscess failed to respond to percutaneous therapy and excision of breast abscess was performed. Histology revealed an invasive carcinoma. He went on to have a mastectomy. Histology should be obtained from breast abscesses not resolving within 2 months of initial percutaneous therapy. Histology could be obtained by ultrasound-guided fine-needle aspiration (FNA), core or vacuum assisted biopsy, or by formal incision and drainage. PMID:22767683

  9. Bladder biopsy

    MedlinePlus

    ... than usual ( oliguria ). You cannot urinate despite a strong urge to do so. Alternative Names Biopsy - bladder Images Bladder catheterization, female Bladder catheterization, male Female urinary tract Male urinary tract Bladder biopsy ...

  10. Multi-institutional Evaluation of Upper Urinary Tract Biopsy Using Backloaded Cup Biopsy Forceps, a Nitinol Basket, and Standard Cup Biopsy Forceps.

    PubMed

    Lama, Daniel J; Safiullah, Shoaib; Patel, Roshan M; Lee, Thomas K; Balani, Jyoti P; Zhang, Lishi; Okhunov, Zhamshid; Margulis, Vitaly; Savage, Stephen J; Uchio, Edward; Landman, Jaime

    2018-04-06

    To compare the performance of 3 contemporary ureteroscopic biopsy devices for the histopathologic diagnosis of upper tract urothelial carcinoma (UTUC). We retrospectively reviewed 145 patients who underwent 182 urothelial biopsies using 2.4F backloaded cup biopsy forceps, a nitinol basket, or 3F standard cup biopsy forceps at 3 tertiary academic centers between 2011 and 2016. Experienced genitourinary pathologists provided an assessment of each specimen without knowledge of the device used for biopsy. For patients who underwent nephroureterectomy without neoadjuvant chemotherapy within 3 months of biopsy-proven UTUC diagnosis, the biopsy grade was compared with both the grade and stage of the surgical specimen. Biopsy utilization varied among the 3 institutions (P <.0001). Significant variabilities in specimen size (P = .001), the presence of intact urothelium (P = .008), and crush artifact (P = .028) were found among the biopsy devices. The quality of specimens from backloaded cup forceps was rated similarly to the nitinol basket (P >.05) and was favored over standard cup forceps specimens. Grade concordance was not affected by specimen size (P >.05), morphology (P >.1), or location (P >.5). No difference existed among the devices in the rate of acquiring a grade concordant biopsy; however, the backloaded cup forceps provided concordant biopsies that could be distinguished as low- and high-grade (P = .02). The backloaded cup forceps and nitinol basket obtained a higher quality urothelial specimen compared with standard cup forceps. Ureteroscopic biopsy device selection did not significantly impact the accuracy of the histologic diagnosis of UTUC. Copyright © 2018 Elsevier Inc. All rights reserved.

  11. Sampling of the anterior apical region results in increased cancer detection and upgrading in transrectal repeat saturation biopsy of the prostate.

    PubMed

    Seles, Maximilian; Gutschi, Thomas; Mayrhofer, Katrin; Fischereder, Katja; Ehrlich, Georg; Gallé, Guenter; Gutschi, Stefan; Pachernegg, Oliver; Pummer, Karl; Augustin, Herbert

    2016-04-01

    To evaluate whether biopsy cores taken via a transrectal approach from the anterior apical region of the prostate in a repeat-biopsy population can result in an increased overall cancer detection rate and in more accurate assessment of the Gleason score. The study was a prospective, randomised (end-fire vs side-fire ultrasound probe) evaluation of 288 men by repeat transrectal saturation biopsy with 28 cores taken from the transition zone, base, mid-lobar, anterior and the anterior apical region located ventro-laterally to the urethra of the peripheral zone. The overall prostate cancer detection rate was 44.4%. Improvement of the overall detection rate by 7.8% could be achieved with additional biopsies of the anterior apical region. Two tumours featuring a Gleason score 7 could only be detected in the anterior apical region. In three cases (2.34%) Gleason score upgrading was achieved by separate analysis of each positive core of the anterior apical region. A five-fold higher cancer detection rate in the anterior apical region compared with the transition zone could be shown. Sampling of the anterior apical region results in higher overall cancer detection rate in repeat transrectal saturation biopsies of the prostate. Specimens from this region can detect clinically significant cancer, improve accuracy of the Gleason Scoring and therefore may alter therapy. © 2015 The Authors BJU International © 2015 BJU International Published by John Wiley & Sons Ltd.

  12. Chemical changes exhibited by latent fingerprints after exposure to vacuum conditions.

    PubMed

    Bright, Nicholas J; Willson, Terry R; Driscoll, Daniel J; Reddy, Subrayal M; Webb, Roger P; Bleay, Stephen; Ward, Neil I; Kirkby, Karen J; Bailey, Melanie J

    2013-07-10

    The effect of vacuum exposure on latent fingerprint chemistry has been evaluated. Fingerprints were analysed using a quartz crystal microbalance to measure changes in mass, gas chromatography mass spectrometry to measure changes in lipid composition and attenuated total reflection Fourier transform infrared spectroscopy (ATR-FTIR) to determine changes in the content of water, fatty acids and their esters after exposure to vacuum. The results are compared with samples aged under ambient conditions. It was found that fingerprints lose around 26% of their mass when exposed to vacuum conditions, equivalent to around 5 weeks ageing under ambient conditions. Further exposure to vacuum causes a significant reduction in the lipid composition of a fingerprint, in particular with the loss of tetradecanoic and pentadecanoic acid, that was not observed in ambient aged samples. There are therefore implications for sequence in which fingerprint development procedures (for example vacuum metal deposition) are carried out, as well as the use of vacuum based methods such as secondary ion mass spectrometry (SIMS) and matrix-assisted laser desorption ionisation (MALDI) in the study of fingerprint chemistry. Copyright © 2013. Published by Elsevier Ireland Ltd.

  13. Application of Ultrasound-Guided Core Biopsy to Minimal-Invasively Diagnose Supraclavicular Fossa Tumors and Minimize the Requirement of Invasive Diagnostic Surgery

    PubMed Central

    Chen, Chun-Nan; Lin, Che-Yi; Chi, Fan-Hsiang; Chou, Chen-Han; Hsu, Ya-Ching; Kuo, Yen-Lin; Lin, Chih-Feng; Chen, Tseng-Cheng; Wang, Cheng-Ping; Lou, Pei-Jen; Ko, Jenq-Yuh; Hsiao, Tzu-Yu; Yang, Tsung-Lin

    2016-01-01

    Abstract Tumors of the supraclavicular fossa (SC) is clinically challenging because of anatomical complexity and tumor pathological diversity. Because of varied diseases entities and treatment choices of SC tumors, making the accurate decision among numerous differential diagnoses is imperative. Sampling by open biopsy (OB) remains the standard procedure for pathological confirmation. However, complicated anatomical structures of SC always render surgical intervention difficult to perform. Ultrasound-guided core biopsy (USCB) is a minimally invasive and office-based procedure for tissue sampling widely applied in many diseases of head and neck. This study aims to evaluate the clinical efficacy and utility of using USCB as the sampling method of SC tumors. From 2009 to 2014, consecutive patients who presented clinical symptoms and signs of supraclavicular tumors and were scheduled to receive sampling procedures for diagnostic confirmation were recruited. The patients received USCB or OB respectively in the initial tissue sampling. The accurate diagnostic rate based on pathological results was 90.2% for USCB, and 93.6% for OB. No significant difference was noted between USCB and OB groups in terms of diagnostic accuracy and the percentage of inadequate specimens. All cases in the USCB group had the sampling procedure completed within 10 minutes, but not in the OB group. No scars larger than 1 cm were found in USCB. Only patients in the OB groups had the need to receive general anesthesia and hospitalization and had scars postoperatively. Accordingly, USCB can serve as the first-line sampling tool for SC tumors with high diagnostic accuracy, minimal invasiveness, and low medical cost. PMID:26825877

  14. Feasibility of in situ, high-resolution correlation of tracer uptake with histopathology by quantitative autoradiography of biopsy specimens obtained under 18F-FDG PET/CT guidance.

    PubMed

    Fanchon, Louise M; Dogan, Snjezana; Moreira, Andre L; Carlin, Sean A; Schmidtlein, C Ross; Yorke, Ellen; Apte, Aditya P; Burger, Irene A; Durack, Jeremy C; Erinjeri, Joseph P; Maybody, Majid; Schöder, Heiko; Siegelbaum, Robert H; Sofocleous, Constantinos T; Deasy, Joseph O; Solomon, Stephen B; Humm, John L; Kirov, Assen S

    2015-04-01

    Core biopsies obtained using PET/CT guidance contain bound radiotracer and therefore provide information about tracer uptake in situ. Our goal was to develop a method for quantitative autoradiography of biopsy specimens (QABS), to use this method to correlate (18)F-FDG tracer uptake in situ with histopathology findings, and to briefly discuss its potential application. Twenty-seven patients referred for a PET/CT-guided biopsy of (18)F-FDG-avid primary or metastatic lesions in different locations consented to participate in this institutional review board-approved study, which complied with the Health Insurance Portability and Accountability Act. Autoradiography of biopsy specimens obtained using 5 types of needles was performed immediately after extraction. The response of autoradiography imaging plates was calibrated using dummy specimens with known activity obtained using 2 core-biopsy needle sizes. The calibration curves were used to quantify the activity along biopsy specimens obtained with these 2 needles and to calculate the standardized uptake value, SUVARG. Autoradiography images were correlated with histopathologic findings and fused with PET/CT images demonstrating the position of the biopsy needle within the lesion. Logistic regression analysis was performed to search for an SUVARG threshold distinguishing benign from malignant tissue in liver biopsy specimens. Pearson correlation between SUVARG of the whole biopsy specimen and average SUVPET over the voxels intersected by the needle in the fused PET/CT image was calculated. Activity concentrations were obtained using autoradiography for 20 specimens extracted with 18- and 20-gauge needles. The probability of finding malignancy in a specimen is greater than 50% (95% confidence) if SUVARG is greater than 7.3. For core specimens with preserved shape and orientation and in the absence of motion, one can achieve autoradiography, CT, and PET image registration with spatial accuracy better than 2 mm. The

  15. Process utility in breast biopsy.

    PubMed

    Swan, J Shannon; Lawrence, William F; Roy, Jessica

    2006-01-01

    To determine whether the waiting trade-off (WTO) is feasible for differentiating short-term biopsy preferences in an acute situation where anxiety is the symptomatic disease state. 75 women with past experience of either breast core-needle biopsy (CNB), more invasive excisional surgical biopsy (EXB), or both, had telephone WTO assessments. Patients' baseline and test-related anxiety were valued by time trade-off (TTO) used to scale the WTO. Rating scales (RS) were obtained for convergent validity assessment with WTO and TTO. Data were obtained in 38 women who had both CNB and EXB ("paired") and 20 who had CNB only and 16 who had EXB only ("unpaired"). Patients rated only the procedure(s) they experienced. Median paired and mean unpaired WTO scores indicated patients were willing to wait significantly longer to avoid EXB (P = 0.0003, P = 0.0002, respectively). The waiting time difference between EXB and CNB was 2.1 weeks greater in unpaired data than paired data. RS scores comparing the procedures were significantly different only for paired data (P < 0.05). Median TTO preferences for baseline (1.00) and test anxiety (0.93) obtained in 74 patients were significantly different (P < 0.0001) and consistent with RS. Correlation was noted between WTO and RS (-0.307 to -0.453, P = 0.0205 to 0.0001). The median EXB quality-adjusted life years toll (1.5 quality-adjusted life days) calculated from pooled WTO data (paired and unpaired) from 54 patients is near a threshold in a published model. The WTO is feasible for discriminating preferences for short-term health states in an acute medical scenario where it might have been expected to be impracticable.

  16. Transrectal ultrasonography-guided biopsy does not reliably identify dominant cancer location in men with low-risk prostate cancer.

    PubMed

    Washington, Samuel L; Bonham, Michael; Whitson, Jared M; Cowan, Janet E; Carroll, Peter R

    2012-07-01

    Study Type - Diagnostic (exploratory cohort) Level of Evidence 2b What's known on the subject? and What does the study add? The widespread use of serum PSA testing followed by TRUS-guided biopsy have resulted in profound prostate cancer stage migration with many patients presenting with focal rather than multifocal disease. There is increasing interest in the use of focal rather than whole-gland treatment. However, current biopsy schemes may still miss cancer or, even when cancer is identified, its extent or grade might not be accurately characterized. In order for focal therapy to be effective, the area of highest tumour volume and/or grade needs to localized accurately. The aim of this study was to assess how well biopsy, as currently performed, locates the focus of highest prostate cancer volume and/or grade. To evaluate the ability of transrectal ultrasonography (TRUS)-guided extended core biopsy to identify the dominant tumour accurately in men with early stage prostate cancer. Patients with early stage, low-risk prostate cancer who subsequently underwent radical prostatectomy (RP) and had complete surgical specimens were identified. Re-review was performed by a single uropathologist using ImageJ software to identify tumour location, dominant grade (DG) and dominant volume (DV). Pathology findings were then compared with biopsy results. A total of 51 men with early stage, low-risk prostate cancer, who had undergone RP, had complete specimens for review and a median of 15 biopsy cores taken for diagnosis and grading. Sixteen men had a single diagnostic biopsy, 21 had one repeat biopsy, and 14 had two or more repeat biopsies. Compared with surgical findings, biopsy correctly identified the sextant with the largest tumour volume in 55% (95% CI 0.5-0.6) of specimens and the highest grade in 37% (95 CI 0.3-0.5). No demographic or clinical factors were significantly associated with identification of DG. Interval between last biopsy and RP, total tissue length taken

  17. IAC Standardized Reporting of Breast Fine-Needle Aspiration Biopsy Cytology.

    PubMed

    Field, Andrew S; Schmitt, Fernando; Vielh, Philippe

    2017-01-01

    There have been many changes in the roles of fine-needle aspiration biopsy (FNAB) and core needle biopsy (CNB) in the diagnostic workup of breast lesions in routine breast clinics and in mammographic breast screening programs, as well as changes in the management algorithms utilized and the treatments available, since the NCI consensus on breast FNAB cytology in 1996. A standardized approach will improve training and performance of FNAB and smear-making techniques, and structured reporting will improve the quality and reproducibility of reports across departments, cities and countries providing a basis for quality assurance measures and improving patient care and facilitating research. Linking cytology reports to management algorithms will increase the clinicians' use of FNAB cytology and where appropriate CNB, and enhance the use of ancillary tests for prognostic testing. The IAC recognizes that the local medical infrastructure and resources for breast imaging, biopsy and treatment will influence the diagnostic workup and management of breast disease, but best practice guidelines should be established and modified as required. © 2016 S. Karger AG, Basel.

  18. Flat epithelial atypia and atypical ductal hyperplasia: carcinoma underestimation rate.

    PubMed

    Ingegnoli, Anna; d'Aloia, Cecilia; Frattaruolo, Antonia; Pallavera, Lara; Martella, Eugenia; Crisi, Girolamo; Zompatori, Maurizio

    2010-01-01

    This study was carried out to determine the underestimation rate of carcinoma upon surgical biopsy after a diagnosis of flat epithelial atypia and atypical ductal hyperplasia and 11-gauge vacuum-assisted breast biopsy. A retrospective review was conducted of 476 vacuum-assisted breast biopsy performed from May 2005 to January 2007 and a total of 70 cases of atypia were identified. Fifty cases (71%) were categorized as pure atypical ductal hyperplasia, 18 (26%) as pure flat epithelial atypia and two (3%) as concomitant flat epithelial atypia and atypical ductal hyperplasia. Each group were compared with the subsequent open surgical specimens. Surgical biopsy was performed in 44 patients with atypical ductal hyperplasia, 15 patients with flat epithelial atypia, and two patients with flat epithelial atypia and atypical ductal hyperplasia. Five cases of atypical ductal hyperplasia were upgraded to ductal carcinoma in situ, three cases of flat epithelial atypia yielded one ductal carcinoma in situ and two cases of invasive ductal carcinoma, and one case of flat epithelial atypia/atypical ductal hyperplasia had invasive ductal carcinoma. The overall rate of malignancy was 16% for atypical ductal hyperplasia (including flat epithelial atypia/atypical ductal hyperplasia patients) and 20% for flat epithelial atypia. The presence of flat epithelial atypia and atypical ductal hyperplasia at biopsy requires careful consideration, and surgical excision should be suggested.

  19. Radial scars without atypia in percutaneous biopsy specimens: can they obviate surgical biopsy?

    PubMed

    Mesa-Quesada, J; Romero-Martín, S; Cara-García, M; Martínez-López, A; Medina-Pérez, M; Raya-Povedano, J L

    To evaluate the need for surgical biopsy in patients diagnosed with radial scars without atypia by percutaneous biopsy. In this retrospective observational study, we selected patients with a histological diagnosis of radial scar in specimens obtained by percutaneous biopsy during an 8-year period. The statistical analysis was centered on patients with radial scar without atypia (we assessed the radiologic presentation, the results of the percutaneous biopsy, and their correlation with the results of surgical biopsy and follow-up) and we added the patients with atypia and cancer in the elaboration of the diagnostic indices. We identified 96 patients with radial scar on percutaneous biopsy; 54 had no atypia, 18 had atypia, and 24 had cancer. Among patients with radial scar without atypia, there were no statistically significant differences between patients who underwent imaging follow-up and those who underwent surgical biopsy (p>0.05). The rate of underdiagnosis for percutaneous biopsy in patients without atypia was 1.9%. The rates of diagnosis obtained with percutaneous biopsy in relation to follow-up and surgical biopsy in the 96 cases were sensitivity 92.3%, specificity 100%, positive predictive value 100%, negative predictive value 97.2%, and accuracy 97.9%. The area under the ROC curve was 0.96 (p<0.001), and the kappa concordance index was 0.95 (p<0.001) CONCLUSIONS: We consider that it is not necessary to perform surgical biopsies in patients with radial scars without atypia on percutaneous biopsies because the rate of underestimation is very low and the concordance between the diagnosis reached by percutaneous biopsy and the definitive diagnosis is very high. Copyright © 2017 SERAM. Publicado por Elsevier España, S.L.U. All rights reserved.

  20. Molecular Weight Cut-Off and Structural Analysis of Vacuum-Assisted Titania Membranes for Water Processing

    PubMed Central

    Abd Jalil, Siti Nurehan; Wang, David K.; Yacou, Christelle; Motuzas, Julius; Smart, Simon; Diniz da Costa, João C.

    2016-01-01

    This work investigates the structural formation and analyses of titania membranes (TM) prepared using different vacuum exposure times for molecular weight (MW) cut-off performance and oil/water separation. Titania membranes were synthesized via a sol-gel method and coated on macroporous alumina tubes followed by exposure to a vacuum between 30 and 1200 s and then calcined at 400 °C. X-ray diffraction and nitrogen adsorption analyses showed that the crystallite size and particle size of titania increased as a function of vacuum time. All the TM membranes were mesoporous with an average pore diameter of ~3.6 nm with an anatase crystal morphology. Water, glucose, sucrose, and polyvinylpyrrolidone with 40 and 360 kDa (PVP-40 kDa and PVP-360 kDa) were used as feed solutions for MW cut-off and hexadecane solution for oil filtration investigation. The TM membranes were not able to separate glucose and sucrose, thus indicating the membrane pore sizes are larger than the kinetic diameter of sucrose of 0.9 nm, irrespective of vacuum exposure time. They also showed only moderate rejection (20%) of the smaller PVP-40 kDa, however, all the membranes were able to obtain an excellent rejection of near 100% for the larger PVP-360 kDa molecule. Furthermore, the TM membranes were tested for the separation of oil emulsions with a high concentration of oil (3000 ppm), reaching high oil rejections of more than 90% of oil. In general, the water fluxes increased with the vacuum exposure time indicating a pore structural tailoring effect. It is therefore proposed that a mechanism of pore size tailoring was formed by an interconnected network of Ti–O–Ti nanoparticles with inter-particle voids, which increased as TiO2 nanoparticle size increased as a function of vacuum exposure time, and thus reduced the water transport resistance through the TM membranes. PMID:28774057

  1. Indian Vacuum Society: The Indian Vacuum Society

    NASA Astrophysics Data System (ADS)

    Saha, T. K.

    2008-03-01

    The Indian Vacuum Society (IVS) was established in 1970. It has over 800 members including many from Industry and R & D Institutions spread throughout India. The society has an active chapter at Kolkata. The society was formed with the main aim to promote, encourage and develop the growth of Vacuum Science, Techniques and Applications in India. In order to achieve this aim it has conducted a number of short term courses at graduate and technician levels on vacuum science and technology on topics ranging from low vacuum to ultrahigh vacuum So far it has conducted 39 such courses at different parts of the country and imparted training to more than 1200 persons in the field. Some of these courses were in-plant training courses conducted on the premises of the establishment and designed to take care of the special needs of the establishment. IVS also regularly conducts national and international seminars and symposia on vacuum science and technology with special emphasis on some theme related to applications of vacuum. A large number of delegates from all over India take part in the deliberations of such seminars and symposia and present their work. IVS also arranges technical visits to different industries and research institutes. The society also helped in the UNESCO sponsored post-graduate level courses in vacuum science, technology and applications conducted by Mumbai University. The society has also designed a certificate and diploma course for graduate level students studying vacuum science and technology and has submitted a syllabus to the academic council of the University of Mumbai for their approval, we hope that some colleges affiliated to the university will start this course from the coming academic year. IVS extended its support in standardizing many of the vacuum instruments and played a vital role in helping to set up a Regional Testing Centre along with BARC. As part of the development of vacuum education, the society arranges the participation of

  2. Vacuum-assisted decellularization: an accelerated protocol to generate tissue-engineered human tracheal scaffolds.

    PubMed

    Butler, Colin R; Hynds, Robert E; Crowley, Claire; Gowers, Kate H C; Partington, Leanne; Hamilton, Nicholas J; Carvalho, Carla; Platé, Manuela; Samuel, Edward R; Burns, Alan J; Urbani, Luca; Birchall, Martin A; Lowdell, Mark W; De Coppi, Paolo; Janes, Sam M

    2017-04-01

    Patients with large tracheal lesions unsuitable for conventional endoscopic or open operations may require a tracheal replacement but there is no present consensus of how this may be achieved. Tissue engineering using decellularized or synthetic tracheal scaffolds offers a new avenue for airway reconstruction. Decellularized human donor tracheal scaffolds have been applied in compassionate-use clinical cases but naturally derived extracellular matrix (ECM) scaffolds demand lengthy preparation times. Here, we compare a clinically applied detergent-enzymatic method (DEM) with an accelerated vacuum-assisted decellularization (VAD) protocol. We examined the histological appearance, DNA content and extracellular matrix composition of human donor tracheae decellularized using these techniques. Further, we performed scanning electron microscopy (SEM) and biomechanical testing to analyze decellularization performance. To assess the biocompatibility of scaffolds generated using VAD, we seeded scaffolds with primary human airway epithelial cells in vitro and performed in vivo chick chorioallantoic membrane (CAM) and subcutaneous implantation assays. Both DEM and VAD protocols produced well-decellularized tracheal scaffolds with no adverse mechanical effects and scaffolds retained the capacity for in vitro and in vivo cellular integration. We conclude that the substantial reduction in time required to produce scaffolds using VAD compared to DEM (approximately 9 days vs. 3-8 weeks) does not compromise the quality of human tracheal scaffold generated. These findings might inform clinical decellularization techniques as VAD offers accelerated scaffold production and reduces the associated costs. Copyright © 2017 The Authors. Published by Elsevier Ltd.. All rights reserved.

  3. Testicular biopsy

    MedlinePlus

    ... Names Biopsy - testicle Images Endocrine glands Male reproductive anatomy Testicular biopsy References Garibaldi LR, Chematilly W. Disorders of pubertal development. In: Kliegman RM, Stanton BF, St. Geme JW, Schor NF, eds. Nelson Textbook of Pediatrics . 20th ed. Philadelphia, PA: Elsevier; 2016: ...

  4. Possibility of transrectal photoacoustic imaging-guided biopsy for detection of prostate cancer

    NASA Astrophysics Data System (ADS)

    Ishihara, Miya; Shinchi, Masayuki; Horiguchi, Akio; Shinmoto, Hiroshi; Tsuda, Hitoshi; Irisawa, Kaku; Wada, Takatsugu; Asano, Tomohiko

    2017-03-01

    A transrectral ultrasonography (TRUS) guided prostate biopsy is mandatory for histological diagnosis in patients with an elevated serum prostate-specific antigen (PSA), but its diagnostic accuracy is not satisfactory; therefore, a considerable number of patients are forced to have an unnecessary repeated biopsy. Photoacoustic (PA) imaging has the ability to visualize the distribution of hemoglobin clearly. Thus, there is the potential to acquire different maps of small vessel networks between cancerous and normal tissue. We developed an original TRUS-type PA probe consisting of a microconvex array transducer with an optical illumination system providing coregistered PA and ultrasound images. The purpose of this study is to demonstrate the clinical possibility of a transrectral PA image. The prostate biopsy cores obtained by transrectal systemic biopsies under TRUS guidance were stained with HE staining and anti-CD34 antibodies as a marker of the endothelium of the blood vessel in order to find a pattern in the map of a small vessel network, which allows for imaging-based identification of prostate cancer. We analyzed the association of PA signal patterns, the cancer location by a magnetic resonance imaging (MRI) study, and the pathological diagnosis with CD34 stains as a prospective intervention study. In order to demonstrate the TRUS-merged-with-PA imaging guided targeted biopsy combined with a standard biopsy for capturing the clinically significant tumors, we developed a puncture needle guide attachment for the original TRUS-type PA probe.

  5. Contrast-Enhanced Ultrasound Guided Biopsy of Undetermined Abdominal Lesions: A Multidisciplinary Decision-Making Approach.

    PubMed

    Mao, Feng; Dong, Yi; Ji, Zhengbiao; Cao, Jiaying; Wang, Wen-Ping

    2017-01-01

    Aim. To investigate the value of contrast-enhanced ultrasound (CEUS) guided biopsy of undetermined abdominal lesions in multidisciplinary treatment (MDT) decision-making approach. Methods. Between Jan 2012 and Dec 2015, 60 consecutive patients (male, 37; female, 23; mean age, 51.3 years ± 14.6) who presented with undetermined abdominal lesions were included. CEUS and core needle percutaneous biopsy was performed under real-time CEUS guidance in all lesions. Data were recorded and compared with conventional ultrasound (US) guidance group ( n = 75). All CEUS findings and clinical data were evaluated in MDT. Results. CEUS enabled the delimitation of more (88.3% versus 41.3%) and larger (14.1 ± 10.7 mm versus 32.3 ± 18.5 mm) nonenhanced necrotic areas. More inner (20.0% versus 6.7%) and surrounding (18.3% versus 2.7%) major vessels were visualized and avoided during biopsies. CEUS-guided biopsy increased the diagnostic accuracy from 93.3% to 98.3%, with correct diagnosis in 57 of 60 lesions (95.0%). The therapeutic plan was influenced by CEUS guided biopsies findings in the majority of patients (98.3%). Conclusion. The combination of CEUS guided biopsy and MDT decision-making approach is useful in the diagnostic work-up and therapeutic management.

  6. Identification of proteomic biomarkers predicting prostate cancer aggressiveness and lethality despite biopsy-sampling error.

    PubMed

    Shipitsin, M; Small, C; Choudhury, S; Giladi, E; Friedlander, S; Nardone, J; Hussain, S; Hurley, A D; Ernst, C; Huang, Y E; Chang, H; Nifong, T P; Rimm, D L; Dunyak, J; Loda, M; Berman, D M; Blume-Jensen, P

    2014-09-09

    Key challenges of biopsy-based determination of prostate cancer aggressiveness include tumour heterogeneity, biopsy-sampling error, and variations in biopsy interpretation. The resulting uncertainty in risk assessment leads to significant overtreatment, with associated costs and morbidity. We developed a performance-based strategy to identify protein biomarkers predictive of prostate cancer aggressiveness and lethality regardless of biopsy-sampling variation. Prostatectomy samples from a large patient cohort with long follow-up were blindly assessed by expert pathologists who identified the tissue regions with the highest and lowest Gleason grade from each patient. To simulate biopsy-sampling error, a core from a high- and a low-Gleason area from each patient sample was used to generate a 'high' and a 'low' tumour microarray, respectively. Using a quantitative proteomics approach, we identified from 160 candidates 12 biomarkers that predicted prostate cancer aggressiveness (surgical Gleason and TNM stage) and lethal outcome robustly in both high- and low-Gleason areas. Conversely, a previously reported lethal outcome-predictive marker signature for prostatectomy tissue was unable to perform under circumstances of maximal sampling error. Our results have important implications for cancer biomarker discovery in general and development of a sampling error-resistant clinical biopsy test for prediction of prostate cancer aggressiveness.

  7. Broad fibrovascular cores may not be an exclusively benign feature in papillary lesions of the breast: a cautionary note.

    PubMed

    Yamaguchi, Rin; Tanaka, Maki; Tse, Gary M; Yamaguchi, Miki; Terasaki, Hiroshi; Nomura, Yoriko; Takenaka, Miki; Naito, Yoshiki; Akiba, Jun; Yano, Hirohisa

    2014-03-01

    A prominent fibrovascular stromal core is one of the widely accepted histological features of breast papillomas, but some papillary carcinomas also show such broad fibrovascular cores, leading to confusion in diagnosis, particularly in needle biopsy specimens. We investigated the histological characteristics of papillary lesions, focusing on broad fibrovascular cores and their relationship with the architectural patterns. Among 185 cases of needle biopsies of papillomas and papillary carcinomas, the number of cases with broad fibrovascular cores in each group was compared. The broad fibrovascular core density in the subsequently resected specimens was evaluated and compared between papillary predominant pattern (papillary structures >80% of tumours) and mixed pattern (papillary, solid, cribriform and others) within the lesions. Significantly more papillary carcinomas than papillomas and B3 atypical papillary lesions had broad fibrovascular cores (p=0.0091 and p=0.0164, respectively). The papillary predominant pattern was more prominent in carcinomas than in papillomas in the needle biopsies (p=0.048) and showed the same tendency in the resections (p=0.058). The broad fibrovascular core density was significantly lower in the 18 papillomas than in the 37 papillary carcinomas (p=0.0079) and was not significantly different between the papillary predominant and mixed patterns in carcinomas and papillomas. Broad fibrovascular cores in mammary papillary lesions are not specific for papillomas, as they are also present focally in papillary carcinomas. As the frequency of papillary carcinoma with broad fibrovascular cores is relatively high, caution in diagnosis has to be exercised, especially in needle biopsy specimens.

  8. Large-core single-mode rib SU8 waveguide using solvent-assisted microcontact molding.

    PubMed

    Huang, Cheng-Sheng; Wang, Wei-Chih

    2008-09-01

    This paper describes a novel fabrication technique for constructing a polymer-based large-core single-mode rib waveguide. A negative tone SU8 photoresist with a high optical transmission over a large wavelength range and stable mechanical properties was used as a waveguide material. A waveguide was constructed by using a polydimethylsiloxane stamp combined with a solvent-assisted microcontact molding technique. The effects on the final pattern's geometry of four different process conditions were investigated. Optical simulations were performed using beam propagation method software. Single-mode beam propagation was observed at the output of the simulated waveguide as well as the actual waveguide through the microscope image.

  9. Lung Biopsies with the Curved Radial Reload™ Stapler.

    PubMed

    ElSaegh, Mohamed Moneer; Petsa, Afroditi; Dunning, Joel

    2016-04-01

    We describe our experience at the James Cook University Hospital (UK) in using the curved Radial Reload™ (RR) stapler (Medtronic, Dublin, Ireland) for lung wedge resections, which is an endoscopic stapler used mainly in endoscopic general surgery. A single center experience (James Cook University Hospital) for patients who had superficial or deep video-assisted thoracoscopic surgery (VATS) lung wedge resection, using the curved RR stapler. Seven patients had superficial or deep VATS lung biopsies-their ages ranged from 38 to 75 years, with a median length of hospital stay of two days (one to six days), and a mean length of hospital stay of 2.5 days. No complications were encountered. The curved RR stapler is effective in several situations and allows fewer firing of staplers. Our experience would suggest that they are as haemostatic and pneumostatic as the straight staplers and can be used effectively in both superficial and deep lung biopsies.

  10. Effects of quadratic coupling and squeezed vacuum injection in an optomechanical cavity assisted with a Bose-Einstein condensate

    NASA Astrophysics Data System (ADS)

    Dalafi, A.; Naderi, M. H.; Motazedifard, Ali

    2018-04-01

    We investigate theoretically a hybrid system consisting of a Bose-Einstein condensate (BEC) trapped inside a laser-driven membrane-in-the-middle optomechanical cavity assisted with squeezed vacuum injection whose moving membrane interacts both linearly and quadratically with the radiation pressure of the cavity. It is shown that such a hybrid system is very suitable for generating strong quadrature squeezing in the mechanical mode of the membrane and the Bogoliubov mode of the BEC in the unresolved sideband regime. More interestingly, by choosing a suitable sign for the quadratic optomechanical coupling (QOC), one can achieve a very high degree of squeezing in the mechanical mode and a strong entanglement between the mechanical and atomic modes without the necessity of using squeezed light injection. Furthermore, the QOC changes the effective oscillation frequencies of both the mechanical and the atomic modes and affects their relaxation times. It can also make the system switch from optical bistability to tristability.

  11. Magnetic Resonance Imaging-Guided Osseous Biopsy in Children With Chronic Recurrent Multifocal Osteomyelitis

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Fritz, Jan, E-mail: jfritz9@jhmi.edu; Tzaribachev, Nikolay; Thomas, Christoph

    2012-02-15

    Purpose: To report the safety and diagnostic performance of magnetic resonance (MRI)-guided core biopsy of osseous lesions in children with chronic recurrent multifocal osteomyelitis (CRMO) that were visible on MRI but were occult on radiography and computed tomography (CT). Materials and Methods: A retrospective analysis of MRI-guided osseous biopsy performed in seven children (four girls and three boys; mean age 13 years (range 11 to 14) with CRMO was performed. Indication for using MRI guidance was visibility of lesions by MRI only. MRI-guided procedures were performed with 0.2-Tesla (Magnetom Concerto; Siemens, Erlangen, Germany; n = 5) or 1.5-T (Magnetom Espree;more » Siemens; n = 2) open MRI systems. Core needle biopsy was obtained using an MRI-compatible 4-mm drill system. Conscious sedation or general anesthesia was used. Parameters evaluated were lesion visibility, technical success, procedure time, complications and microbiology, cytology, and histopathology findings. Results: Seven of seven (100%) targeted lesions were successfully visualized and sampled. All obtained specimens were sufficient for histopathological analysis. Length of time of the procedures was 77 min (range 64 to 107). No complications occurred. Histopathology showed no evidence of malignancy, which was confirmed at mean follow-up of 50 months (range 28 to 78). Chronic nonspecific inflammation characteristic for CRMO was present in four of seven (58%) patients, and edema with no inflammatory cells was found in three of seven (42%) patients. There was no evidence of infection in any patient. Conclusion: MRI-guided osseous biopsy is a safe and accurate technique for the diagnosis of pediatric CRMO lesions that are visible on MRI only.« less

  12. Raman spectroscopic sensing of carbonate intercalation in breast microcalcifications at stereotactic biopsy

    PubMed Central

    Sathyavathi, R.; Saha, Anushree; Soares, Jaqueline S.; Spegazzini, Nicolas; McGee, Sasha; Rao Dasari, Ramachandra; Fitzmaurice, Maryann; Barman, Ishan

    2015-01-01

    Microcalcifications are an early mammographic sign of breast cancer and frequent target for stereotactic biopsy. Despite their indisputable value, microcalcifications, particularly of the type II variety that are comprised of calcium hydroxyapatite deposits, remain one of the least understood disease markers. Here we employed Raman spectroscopy to elucidate the relationship between pathogenicity of breast lesions in fresh biopsy cores and composition of type II microcalcifications. Using a chemometric model of chemical-morphological constituents, acquired Raman spectra were translated to characterize chemical makeup of the lesions. We find that increase in carbonate intercalation in the hydroxyapatite lattice can be reliably employed to differentiate benign from malignant lesions, with algorithms based only on carbonate and cytoplasmic protein content exhibiting excellent negative predictive value (93–98%). Our findings highlight the importance of calcium carbonate, an underrated constituent of microcalcifications, as a spectroscopic marker in breast pathology evaluation and pave the way for improved biopsy guidance. PMID:25927331

  13. Raman spectroscopic sensing of carbonate intercalation in breast microcalcifications at stereotactic biopsy

    NASA Astrophysics Data System (ADS)

    Sathyavathi, R.; Saha, Anushree; Soares, Jaqueline S.; Spegazzini, Nicolas; McGee, Sasha; Rao Dasari, Ramachandra; Fitzmaurice, Maryann; Barman, Ishan

    2015-04-01

    Microcalcifications are an early mammographic sign of breast cancer and frequent target for stereotactic biopsy. Despite their indisputable value, microcalcifications, particularly of the type II variety that are comprised of calcium hydroxyapatite deposits, remain one of the least understood disease markers. Here we employed Raman spectroscopy to elucidate the relationship between pathogenicity of breast lesions in fresh biopsy cores and composition of type II microcalcifications. Using a chemometric model of chemical-morphological constituents, acquired Raman spectra were translated to characterize chemical makeup of the lesions. We find that increase in carbonate intercalation in the hydroxyapatite lattice can be reliably employed to differentiate benign from malignant lesions, with algorithms based only on carbonate and cytoplasmic protein content exhibiting excellent negative predictive value (93-98%). Our findings highlight the importance of calcium carbonate, an underrated constituent of microcalcifications, as a spectroscopic marker in breast pathology evaluation and pave the way for improved biopsy guidance.

  14. Raman spectroscopic sensing of carbonate intercalation in breast microcalcifications at stereotactic biopsy.

    PubMed

    Sathyavathi, R; Saha, Anushree; Soares, Jaqueline S; Spegazzini, Nicolas; McGee, Sasha; Rao Dasari, Ramachandra; Fitzmaurice, Maryann; Barman, Ishan

    2015-04-30

    Microcalcifications are an early mammographic sign of breast cancer and frequent target for stereotactic biopsy. Despite their indisputable value, microcalcifications, particularly of the type II variety that are comprised of calcium hydroxyapatite deposits, remain one of the least understood disease markers. Here we employed Raman spectroscopy to elucidate the relationship between pathogenicity of breast lesions in fresh biopsy cores and composition of type II microcalcifications. Using a chemometric model of chemical-morphological constituents, acquired Raman spectra were translated to characterize chemical makeup of the lesions. We find that increase in carbonate intercalation in the hydroxyapatite lattice can be reliably employed to differentiate benign from malignant lesions, with algorithms based only on carbonate and cytoplasmic protein content exhibiting excellent negative predictive value (93-98%). Our findings highlight the importance of calcium carbonate, an underrated constituent of microcalcifications, as a spectroscopic marker in breast pathology evaluation and pave the way for improved biopsy guidance.

  15. Majority of flat epithelial atypia diagnosed on biopsy do not require surgical excision.

    PubMed

    Chan, Patrick Mun Yew; Chotai, Niketa; Lai, Eileen Shujuan; Sin, Pei Yi; Chen, Juliana; Lu, Sarah Qinghui; Goh, Mui Heng; Chong, Bee Kiang; Ho, Bernard Chi Shern; Tan, Ern Yu

    2018-02-01

    Borderline risk lesions such as flat epithelial atypia (FEA) are increasingly being diagnosed on biopsy. The need for surgery is being debated. In this study, we determined the frequency of histological upgrade following a diagnosis of FEA on biopsy and evaluated potential predictive factors. Retrospective review was done of 194 women who underwent biopsy of indeterminate lesions (total 195 lesions) that were diagnosed as FEA. The review covered a 10-year period. Cases where malignancy was also present together with FEA within the same biopsy cores were excluded. Lesions diagnosed as FEA on biopsy were mostly asymptomatic and presented as microcalcifications on mammogram. Flat epithelial atypia was the only abnormality detected in one-third of cases, was associated with a benign or another borderline lesion in another third and was associated with atypical ductal hyperplasia (ADH) in another third. Six patients (3.1%) were later found to have ductal carcinoma-in-situ (DCIS) at surgery. The presence of ADH in the biopsy was the only predictor of histological upgrade to malignancy (P = 0.04, OR 11.24, 95% CI 1.10 - 115.10), and was present in 5 of the 6 patients. Surgery was advised in the last patient because of radiology-pathology discordance. Thirty-six lesions (18.5%) were not excised and no interval progression or malignancy was found on follow up. Histological upgrade to malignancy was uncommon in lesions found on biopsy to be FEA. Non-operative management of biopsy-proven FEA can be considered in the absence of ADH and radiology-pathology discordance. Copyright © 2017 Elsevier Ltd. All rights reserved.

  16. Ultrasound-Guided Breast Biopsy

    MedlinePlus

    ... the type of biopsy being performed or the design of the biopsy machine, a biopsy of tissue ... cost information. The costs for specific medical imaging tests, treatments and procedures may vary by geographic region. ...

  17. The risk of finding focal cancer (less than 3 mm) remains high on re-biopsy of patients with persistently increased prostate specific antigen but the clinical significance is questionable.

    PubMed

    Zackrisson, Bjørn; Aus, Gunnar; Bergdahl, Svante; Lilja, Hans; Lodding, Pär; Pihl, Carl-Gustav; Hugosson, Jonas

    2004-04-01

    We evaluated the significance of focal prostate cancer found in sextant biopsies in men participating in a biennial prostate specific antigen (PSA) based screening program. In 1995, 10000 men 50 to 65 years old were randomized to biennial screening with PSA testing. Sextant biopsies were recommended when total PSA was 3 ng/ml or greater at screening rounds 1 and 2, and 2.54 ng/ml or greater at subsequent screening rounds. Focal cancer was defined as total a core cancer length of less than 3 mm in the biopsy specimen. Low volume cancer was defined as a total tumor volume of less than 0.5 cm in the radical retropubic prostatectomy specimen. The number of men who underwent biopsy and the number of cancers detected in the 5 possible sets of biopsies were 1725 and 402, 706 and 124, 307 and 36, 103 and 9, and 13 and 0, respectively. The risk of detecting focal cancer was 7.9%, 10.2%, 7.5%, 5.8% and 0%, respectively, but the relative ratio (focal-to-all cancers) increased 34%, 58%, 64%, 67% and, not applicable, respectively. In men with a total core cancer length of less than 10 mm there was no correlation between core cancer length and total tumor volume, as measured in the prostatectomy specimen. Two-thirds of men with a total core cancer length of less than 3 mm had a tumor volume of greater than 0.5 cm, while the risk of low volume cancer was less than 5% only in men with a total core cancer length of greater than 10 mm. In a repeat PSA based screening program sextant biopsies are of little or no value for predicting tumor volume.

  18. Abdominal wall fat pad biopsy

    MedlinePlus

    Amyloidosis - abdominal wall fat pad biopsy; Abdominal wall biopsy; Biopsy - abdominal wall fat pad ... most common method of taking an abdominal wall fat pad biopsy . The health care provider cleans the ...

  19. [Learning curve of vacuum extraction in residency: a preliminary study].

    PubMed

    Velemir, L; Vendittelli, F; Bonnefoy, C; Accoceberry, M; Savary, D; Gallot, D

    2009-09-01

    The aim of this study was to assess the lurning curve of young residents for vacuum extraction. All vacuum extractions performed in our department by five residents (< or =5th semester) during a study period of nine months were systematically supervised by a senior who fulfilled an assessment questionnaire from which was calculated a score reflecting the quality of the extraction. Fifty-four vacuum extractions were assessed with a mean of 10.8+/-2.9 (range, 10-13) procedures by resident. We compared the group including the six first procedures performed by each resident (group 1, n = 30) with the group including the following procedures (group 2, n = 24). We observed in the group 2 compared to the group 1, a significant improvement of the scores mean (12.3+/-5.4 vs 8.4+/-6.2, p = 0.016) and a significant reduction of the need for manual assistance by the senior (12.5% vs 40%, p = 0.034). We report a method for the learning and assessment of vacuum extraction feasible at "the bed" of the patient. This approach allows to observe a significant progression of the resident for the technique of vacuum extraction on a dozen of procedures.

  20. Upgrading and Downgrading of Prostate Cancer from Biopsy to Radical Prostatectomy: Incidence and Predictive Factors Using the Modified Gleason Grading System and Factoring in Tertiary Grades

    PubMed Central

    Epstein, Jonathan I.; Feng, Zhaoyong; Trock, Bruce J.; Pierorazio, Phillip M.

    2015-01-01

    Background Prior studies assessing the correlation of Gleason score (GS) at needle biopsy and corresponding radical prostatectomy (RP) predated the use of the modified Gleason scoring system and did not factor in tertiary grade patterns. Objective To assess the relation of biopsy and RP grade in the largest study to date. Design, setting, and participants A total of 7643 totally embedded RP and corresponding needle biopsies (2004–2010) were analyzed according to the updated Gleason system. Interventions All patients underwent prostate biopsy prior to RP. Measurements The relation of upgrading or downgrading to patient and cancer characteristics was compared using the chi-square test, Student t test, and multivariable logistic regression. Results and limitations A total of 36.3% of cases were upgraded from a needle biopsy GS 5–6 to a higher grade at RP (11.2% with GS 6 plus tertiary). Half of the cases had matching GS 3 + 4 = 7 at biopsy and RP with an approximately equal number of cases downgraded and upgraded at RP. With biopsy GS 4 + 3 = 7, RP GS was almost equally 3 + 4 = 7 and 4 + 3 = 7. Biopsy GS 8 led to an almost equal distribution between RP GS 4 + 3 = 7, 8, and 9–10. A total of 58% of the cases had matching GS 9–10 at biopsy and RP. In multivariable analysis, increasing age (p < 0.0001), increasing serum prostate-specific antigen level (p < 0.0001), decreasing RP weight (p < 0.0001), and increasing maximum percentage cancer/core (p < 0.0001) predicted the upgrade from biopsy GS 5–6 to higher at RP. Despite factoring in multiple variables including the number of positive cores and the maximum percentage of cancer per core, the concordance indexes were not sufficiently high to justify the use of nomograms for predicting upgrading and downgrading for the individual patient. Conclusions Almost 20% of RP cases have tertiary patterns. A needle biopsy can sample a tertiary higher Gleason pattern in the RP, which is then not recorded in the standard GS

  1. Upgrading and downgrading of prostate cancer from biopsy to radical prostatectomy: incidence and predictive factors using the modified Gleason grading system and factoring in tertiary grades.

    PubMed

    Epstein, Jonathan I; Feng, Zhaoyong; Trock, Bruce J; Pierorazio, Phillip M

    2012-05-01

    Prior studies assessing the correlation of Gleason score (GS) at needle biopsy and corresponding radical prostatectomy (RP) predated the use of the modified Gleason scoring system and did not factor in tertiary grade patterns. To assess the relation of biopsy and RP grade in the largest study to date. A total of 7643 totally embedded RP and corresponding needle biopsies (2004-2010) were analyzed according to the updated Gleason system. All patients underwent prostate biopsy prior to RP. The relation of upgrading or downgrading to patient and cancer characteristics was compared using the chi-square test, Student t test, and multivariable logistic regression. A total of 36.3% of cases were upgraded from a needle biopsy GS 5-6 to a higher grade at RP (11.2% with GS 6 plus tertiary). Half of the cases had matching GS 3+4=7 at biopsy and RP with an approximately equal number of cases downgraded and upgraded at RP. With biopsy GS 4+3=7, RP GS was almost equally 3+4=7 and 4+3=7. Biopsy GS 8 led to an almost equal distribution between RP GS 4+3=7, 8, and 9-10. A total of 58% of the cases had matching GS 9-10 at biopsy and RP. In multivariable analysis, increasing age (p<0.0001), increasing serum prostate-specific antigen level (p<0.0001), decreasing RP weight (p<0.0001), and increasing maximum percentage cancer/core (p<0.0001) predicted the upgrade from biopsy GS 5-6 to higher at RP. Despite factoring in multiple variables including the number of positive cores and the maximum percentage of cancer per core, the concordance indexes were not sufficiently high to justify the use of nomograms for predicting upgrading and downgrading for the individual patient. Almost 20% of RP cases have tertiary patterns. A needle biopsy can sample a tertiary higher Gleason pattern in the RP, which is then not recorded in the standard GS reporting, resulting in an apparent overgrading on the needle biopsy. Copyright © 2012 European Association of Urology. Published by Elsevier B.V. All

  2. A new technique for repeated biopsies of the mammary gland in dairy cows allotted to Latin-square design studies

    PubMed Central

    de Lima, Luciano S.; Martineau, Eric; De Marchi, Francilaine E.; Palin, Marie-France; dos Santos, Geraldo T.; Petit, Hélène V.

    2016-01-01

    The objective of this study was to develop a technique for carrying out repeated biopsies of the mammary gland of lactating dairy cows that provides enough material to monitor enzyme activities and gene expression in mammary secretory tissue. A total of 16 Holstein cows were subjected to 4 mammary biopsies each at 3-week intervals for a total of 64 biopsies. A 0.75-cm incision was made through the skin and subcutaneous tissue of the mammary gland and a trocar and cannula were inserted using a circular motion. The trocar was withdrawn and a syringe was plugged into the base of the cannula to create a vacuum for sampling mammary tissue. To reduce bleeding, hand pressure was put on the surgery site after biopsy and skin closure and ice was applied for at least 2 h after the biopsy using a cow bra. The entire procedure took an average of 25 min. Two attempts were usually enough to obtain 800 mg of tissue. Visual examination of milk samples 10 d after the biopsy indicated no trace of blood, except in samples from 2 cows. All wounds healed without infection and subcutaneous hematomas resorbed within 7 d. There was no incidence of mastitis throughout the lactation. This technique provides a new tool for biopsy of the mammary gland repeated at short intervals with the main effect being a decrease in milk production. Although secondary complications leading to illness or death are always a risk with any procedure, this biopsy technique was carried out without complications to the health of animals and with no incidence of mastitis during the lactation. PMID:27408336

  3. A new technique for repeated biopsies of the mammary gland in dairy cows allotted to Latin-square design studies.

    PubMed

    de Lima, Luciano S; Martineau, Eric; De Marchi, Francilaine E; Palin, Marie-France; Dos Santos, Geraldo T; Petit, Hélène V

    2016-07-01

    The objective of this study was to develop a technique for carrying out repeated biopsies of the mammary gland of lactating dairy cows that provides enough material to monitor enzyme activities and gene expression in mammary secretory tissue. A total of 16 Holstein cows were subjected to 4 mammary biopsies each at 3-week intervals for a total of 64 biopsies. A 0.75-cm incision was made through the skin and subcutaneous tissue of the mammary gland and a trocar and cannula were inserted using a circular motion. The trocar was withdrawn and a syringe was plugged into the base of the cannula to create a vacuum for sampling mammary tissue. To reduce bleeding, hand pressure was put on the surgery site after biopsy and skin closure and ice was applied for at least 2 h after the biopsy using a cow bra. The entire procedure took an average of 25 min. Two attempts were usually enough to obtain 800 mg of tissue. Visual examination of milk samples 10 d after the biopsy indicated no trace of blood, except in samples from 2 cows. All wounds healed without infection and subcutaneous hematomas resorbed within 7 d. There was no incidence of mastitis throughout the lactation. This technique provides a new tool for biopsy of the mammary gland repeated at short intervals with the main effect being a decrease in milk production. Although secondary complications leading to illness or death are always a risk with any procedure, this biopsy technique was carried out without complications to the health of animals and with no incidence of mastitis during the lactation.

  4. Comparison between fine needle aspiration cytology (FNAC) and core needle biopsy (CNB) in the diagnosis of breast lesions.

    PubMed

    Moschetta, M; Telegrafo, M; Carluccio, D A; Jablonska, J P; Rella, L; Serio, Gabriella; Carrozzo, M; Stabile Ianora, A A; Angelelli, G

    2014-01-01

    To compare the diagnostic accuracy of fine-needle aspiration cytology (FNAC) and core needle biopsy (CNB) in patients with USdetected breast lesions. Between September 2011 and May 2013, 3469 consecutive breast US examinations were performed. 400 breast nodules were detected in 398 patients. 210 FNACs and 190 CNBs were performed. 183 out of 400 (46%) lesions were surgically removed within 30 days form diagnosis; in the remaining cases, a six month follow up US examination was performed. Sensitivity, specificity, diagnostic accuracy, positive predictive (PPV) and negative predictive (NPV) values were calculated for FNAC and CNB. 174 out of 400 (43%) malignant lesions were found while the remaining 226 resulted to be benign lesions. 166 out of 210 (79%) FNACs and 154 out of 190 (81%) CNBs provided diagnostic specimens. Sensitivity, specificity, diagnostic accuracy, PPV and NPV of 97%, 94%, 95%, 91% and 98% were found for FNAC, and values of 92%, 82%, 89%, 92% and 82% were obtained for CNB. Sensitivity, specificity, diagnostic accuracy, PPV and NPV of 97%, 96%, 96%, 97% and 96% were found for FNAC, and values of 97%, 96%, 96%, 97% and 96% were obtained for CNB. FNAC and CNB provide similar values of diagnostic accuracy.

  5. [Diagnostic accuracy research of needle puncture biopsy during operation for pulmonary single nodules].

    PubMed

    Chen, Jin-feng; Liu, Yi-nan; Wu, Nan; Feng, Yuan; Wang, Jia; Lü, Chao; Wang, Yu-zhao; Pei, Yu-quan; Yan, Shi; Zheng, Qing-feng; Zhang, Li-jian; Yang, Yue

    2012-04-01

    To investigate the diagnostic accuracy of needle puncture biopsy and pathological examination of frozen during operation for pulmonary nodules, and whether this diagnostic method can replace tumor resection examination. Totally 50 patients (28 males and 22 females, average age was 59 years) who had the single nodule after imaging examination without any pathological diagnostic from January to October 2010 were selected in this research work. During open operation or video assisted thoracic surgery, needle (14 G model) was used to puncture biopsy for pathological examination of frozen. All the adverse events during puncture biopsy would be recorded. The resection specimens would be accepted paraffin pathological examination. The relationship between puncture frozen pathological and paraffin pathological examination was analyzed. All tumor sizes were ranged from 1.0 cm × 0.6 cm to 5.6 cm × 9.0 cm. The paraffin pathological examination after operation as the golden standard, there were 7 cases of benign tumor and 43 cases of malignant tumor. The diagnostic sensitivity of puncture biopsy was 90.7%, the specificity was 100%, the positive predictive value was 100% and the negative predictive value was 63.6%. There were 11 cases of benign tumor diagnosed by needle puncture biopsy, among which 4 cases were proved as malignant tumor by paraffin pathology, and the false negative rate was 9.3%. The main risk of puncture biopsy was bleeding after puncture immediately, and the rate was 4.0% (2/50). The puncture biopsy during operation had a high specificity for malignant lung tumor, and there was a certain false negative rate for benign tumor. Puncture biopsy and pathological examination of frozen tissue can replace tumor section biopsy in a way.

  6. Should reporting of peri-neural invasion and extra prostatic extension be mandatory in prostate cancer biopsies? correlation with outcome in biopsy cases treated conservatively

    PubMed Central

    Ahmad, Amar S.; Parameshwaran, Vishnu; Beltran, Luis; Fisher, Gabrielle; North, Bernard V.; Greenberg, David; Soosay, Geraldine; Møller, Henrik; Scardino, Peter; Cuzick, Jack; Berney, Daniel M.

    2018-01-01

    The identification of perineural invasion (PNI) and extraprostatic extension (ECE) in prostate cancer (PC) biopsies is time consuming and can be difficult. Although this is required information in many datasets, there is little evidence on their effect on outcome in patients treated conservatively. Cases of PC were identified from three cancer registries in the UK from men with clinically localized prostate cancer diagnosed by needle biopsy from 1990–2003. The endpoint was prostate cancer death (DOD). Patients treated radically within 6 months, those with objective evidence of metastases or who had prior hormone therapy were excluded. Follow-up was through cancer registries up until 2012. Deaths were divided into those from PC and those from other causes, according to WHO criteria. 988 biopsy cases (6522 biopsy cores) were centrally reviewed by three uropathologists and assigned a Gleason score and Grade Group (GG). The presence of both PNI and ECE was recorded. Of 988 patients, PNI was present in 288 (DOD = 75) and ECE in 23 (DOD = 5). On univariable analysis PNI was highly significantly associated with DOD (hazard ratio [HR] 2.28, 95% CI: 1.68, 3.1, log-rank test p-value = 4.8 × 10–8), but ECE was not (log-rank test p-value = 0.334). On multivariable analysis with GG, serum PSA (per 10%), clinical stage and extent of disease (per 10%), PNI lost significance (HR 1.16, 95% CI: 0.83, 1.63, likelihood ratio test p-value = 0.371). The utility of routinely examining prostate biopsies for ECE and PNI is doubtful as it is not independently associated with higher grade, stage or prognosis. PMID:29755671

  7. Should reporting of peri-neural invasion and extra prostatic extension be mandatory in prostate cancer biopsies? correlation with outcome in biopsy cases treated conservatively.

    PubMed

    Ahmad, Amar S; Parameshwaran, Vishnu; Beltran, Luis; Fisher, Gabrielle; North, Bernard V; Greenberg, David; Soosay, Geraldine; Møller, Henrik; Scardino, Peter; Cuzick, Jack; Berney, Daniel M

    2018-04-17

    The identification of perineural invasion (PNI) and extraprostatic extension (ECE) in prostate cancer (PC) biopsies is time consuming and can be difficult. Although this is required information in many datasets, there is little evidence on their effect on outcome in patients treated conservatively. Cases of PC were identified from three cancer registries in the UK from men with clinically localized prostate cancer diagnosed by needle biopsy from 1990-2003. The endpoint was prostate cancer death (DOD). Patients treated radically within 6 months, those with objective evidence of metastases or who had prior hormone therapy were excluded. Follow-up was through cancer registries up until 2012. Deaths were divided into those from PC and those from other causes, according to WHO criteria. 988 biopsy cases (6522 biopsy cores) were centrally reviewed by three uropathologists and assigned a Gleason score and Grade Group (GG). The presence of both PNI and ECE was recorded. Of 988 patients, PNI was present in 288 (DOD = 75) and ECE in 23 (DOD = 5). On univariable analysis PNI was highly significantly associated with DOD (hazard ratio [HR] 2.28, 95% CI: 1.68, 3.1, log-rank test p -value = 4.8 × 10 -8 ), but ECE was not (log-rank test p -value = 0.334). On multivariable analysis with GG, serum PSA (per 10%), clinical stage and extent of disease (per 10%), PNI lost significance (HR 1.16, 95% CI: 0.83, 1.63, likelihood ratio test p -value = 0.371). The utility of routinely examining prostate biopsies for ECE and PNI is doubtful as it is not independently associated with higher grade, stage or prognosis.

  8. Ultrasonic Spray Drying vs High Vacuum and Microwaves Technology for Blueberries

    NASA Astrophysics Data System (ADS)

    Candia-Muñoz, N.; Ramirez-Bunster, M.; Vargas-Hernández, Y.; Gaete-Garretón, L.

    Interest in high quality foods: good taste and a high content of nutrients with healthy beneficial effects are increasing. Fruits have good properties but, they are lost because the oxidation process, additionally, for different reasons a 40% of harvested fruit are lost. To conserve the fruit properties an ultrasonic assisted spray dryer was developed and tested, comparing its results with microwave-vacuum drying technology. Results did shown taste, color, smell, particle shape and size distribution better than the conventional one. The antioxidants conservation were quite good except in the anthocyanins, in which the microwave and vacuum technology shown best results.

  9. Lung biopsy with a 12-gauge cutting needle is possible using an insertion sheath in animal models.

    PubMed

    Izumi, Yotaro; Oyama, Takahiko; Kawamura, Masafumi; Kobayashi, Koichi

    2004-11-01

    The volume of lung tumor core biopsy specimens has been restricted because of concerns for complications such as bleeding and air leakage. In this animal experiment, we investigated the possibility of larger bore biopsies through the peripheral lung parenchyma. Lung biopsy was done in male domestic pigs (n= 4) under thoracotomy. A single biopsy using a 12-gauge cutting biopsy needle was done with sheath (sheath group, eight biopsies) or without sheath (nonsheath group, eight biopsies). After biopsy, bleeding time, bleeding amount, and positive airway pressure causing air leakage from the insertion site was compared between groups (Mann-Whitney U test). To observe long-term effects in closed-chest animals, percutaneous lung biopsy with the use of a sheath was carried out percutaneously in male beagles (n = 9). The animals were observed for 3 weeks. In the pigs (sheath group) after biopsy, bleeding flowed through the sheath and formed a sheath-molded fibrin plug that secured the insertion site. Bleeding time and amount decreased significantly in the sheath group compared with the nonsheath group (115 +/- 108 versus 295 +/- 150 seconds, P = .018, and 37 +/- 41 versus 98 +/- 72 grams, P= .027, respectively). Air leakage pressure was significantly higher in the sheath group compared with the nonsheath group (37 +/- 6 versus 18 +/- 5 cmH2O, P = .001). In the beagles, no complications such as pneumothorax, hemothorax, or airway bleeding was apparent. Although we have not evaluated lung tumor biopsy per se, lung tumor biopsy with a 12-gauge cutting needle may be possible with a use of a sheath.

  10. Effect of Needle Size in Ultrasound-guided Core Needle Breast Biopsy: Comparison of 14-, 16-, and 18-Gauge Needles.

    PubMed

    Giuliani, Michela; Rinaldi, Pierluigi; Rella, Rossella; Fabrizi, Gina; Petta, Federica; Carlino, Giorgio; Di Leone, Alba; Mulè, Antonino; Bufi, Enida; Romani, Maurizio; Belli, Paolo; Bonomo, Lorenzo

    2017-11-01

    The aim of the present study was to assess the diagnostic accuracy of ultrasound-guided core needle biopsy (US-CNB) of breast lesions, comparing smaller needles (16- and 18-gauge) with the 14-gauge needle, and to analyze the lesion characteristics influencing US-CNB diagnostic performance. All the patients provided informed consent before the biopsy procedure. The data from breast lesions that had undergone US-CNB in our institution from January 2011 to January 2015 were retrospectively reviewed. The inclusion criterion was the surgical histopathologic examination findings of the entire lesion or radiologic follow-up data for ≥ 24 months. The exclusion criterion was the use of preoperative neoadjuvant therapy. The US-CNB results were compared with the surgical pathologic results or with the follow-up findings in the 3 needle size groups (14-, 16-, and 18-gauge). The needle size- and lesion characteristic-specific diagnostic accuracy parameters were evaluated. Statistical analysis was performed using a dedicated software program, and P ≤ .01 was considered significant. A total of 1118 US-CNB cases (1042 patients) were included. Of the 1118 cases, 630 (56.3%) were in the 14-gauge group, 136 (12.2%) in the 16-gauge, and 352 (31.5%) in the 18-gauge needle group. Surgery was performed on 800 lesions (71.6%). Of these, 619 were malignant, 77 were high risk, and 104 were benign. The remaining 318 lesions (28.4%) underwent follow-up imaging studies. All the lesions were stable and, therefore, were considered benign. No differences were observed in the diagnostic accuracy parameters among the 3 needle size groups (P > .01). The false-negative rate was greater for lesions < 10 mm (7.2%) (P < .01) but without statistically significant differences among the 3 gauges (P > .01). US-CNB performed with small needles (16 and 18 gauge) had the same diagnostic accuracy as that performed with 14-gauge needles, regardless of the lesion characteristics. Copyright © 2017

  11. Quantitative Proteomic Analysis of Optimal Cutting Temperature (OCT) Embedded Core-Needle Biopsy of Lung Cancer

    NASA Astrophysics Data System (ADS)

    Zhao, Xiaozheng; Huffman, Kenneth E.; Fujimoto, Junya; Canales, Jamie Rodriguez; Girard, Luc; Nie, Guangjun; Heymach, John V.; Wistuba, Igacio I.; Minna, John D.; Yu, Yonghao

    2017-10-01

    With recent advances in understanding the genomic underpinnings and oncogenic drivers of pathogenesis in different subtypes, it is increasingly clear that proper pretreatment diagnostics are essential for the choice of appropriate treatment options for non-small cell lung cancer (NSCLC). Tumor tissue preservation in optimal cutting temperature (OCT) compound is commonly used in the surgical suite. However, proteins recovered from OCT-embedded specimens pose a challenge for LC-MS/MS experiments, due to the large amounts of polymers present in OCT. Here we present a simple workflow for whole proteome analysis of OCT-embedded NSCLC tissue samples, which involves a simple trichloroacetic acid precipitation step. Comparisons of protein recovery between frozen versus OCT-embedded tissue showed excellent consistency with more than 9200 proteins identified. Using an isobaric labeling strategy, we quantified more than 5400 proteins in tumor versus normal OCT-embedded core needle biopsy samples. Gene ontology analysis indicated that a number of proliferative as well as squamous cell carcinoma (SqCC) marker proteins were overexpressed in the tumor, consistent with the patient's pathology based diagnosis of "poorly differentiated SqCC". Among the most downregulated proteins in the tumor sample, we noted a number of proteins with potential immunomodulatory functions. Finally, interrogation of the aberrantly expressed proteins using a candidate approach and cross-referencing with publicly available databases led to the identification of potential druggable targets in DNA replication and DNA damage repair pathways. We conclude that our approach allows LC-MS/MS proteomic analyses on OCT-embedded lung cancer specimens, opening the way to bring powerful proteomics into the clinic. [Figure not available: see fulltext.

  12. Optimizing Vacuum Assisted Resin Transfer Moulding (VARTM) Processing Parameters to Improve Part Quality

    NASA Astrophysics Data System (ADS)

    Polowick, Christopher

    The Low Cost Composites (LCC) group at Carleton University is studying out-of-autoclave composite manufacturing processes such as Vacuum Assisted Resin Transfer Moulding (VARTM) and Closed Cavity Bag Moulding (CCBM). These processes are used to produce inexpensive and high performance components for the GeoSurv II, an Unmanned Aerial Vehicle (UAV) being developed at Carleton University. This research has focused on optimizing VARTM processing parameters to reduce the weight and improve the strength and surface finish of GeoSurv II composite components. A simulation was developed to model resin flow through in VARTM infusions and was used to simulate mould filling and resin emptying of the GeoSurv II inverted V-empennage and mission avionics hatch. The resin infusion schemes of these parts were designed to ensure full preform resin saturation, and minimize thickness variations. An experimental study of the effects of the presence of a corner on composite thickness, void content, and strength was conducted. It was found that inside corners result in local increases in thickness and void content due to poor preform compaction. A novel bagging technique was developed to improve corner compaction, and this technique was shown to reduce thickness variability and void content. The strength, void content, and thickness variation were found to be heavily dependent on corner radius, with corner radii greater than 6.4 mm displaying the greatest improvement in performance for the layups considered. The design of the empennage and hatch mould incorporated the results of this study to improve the quality of these components.

  13. Anxiety prior to breast biopsy: Relationships with length of time from breast biopsy recommendation to biopsy procedure and psychosocial factors.

    PubMed

    Hayes Balmadrid, Melissa A; Shelby, Rebecca A; Wren, Anava A; Miller, Lauren S; Yoon, Sora C; Baker, Jay A; Wildermann, Liz A; Soo, Mary Scott

    2017-04-01

    This study investigated how time from breast biopsy recommendation to biopsy procedure affected pre-biopsy anxiety ( N = 140 women), and whether the relationship between wait time and anxiety was affected by psychosocial factors (chronic life stress, traumatic events, social support). Analyses showed a significant interaction between wait time and chronic life stress. Increased time from biopsy recommendation was associated with greater anxiety in women with low levels of life stress. Women with high levels of life stress experienced increased anxiety regardless of wait time. These results suggest that women may benefit from shorter wait times and receiving strategies for managing anxiety.

  14. Vacuum mechatronics

    NASA Technical Reports Server (NTRS)

    Hackwood, Susan; Belinski, Steven E.; Beni, Gerardo

    1989-01-01

    The discipline of vacuum mechatronics is defined as the design and development of vacuum-compatible computer-controlled mechanisms for manipulating, sensing and testing in a vacuum environment. The importance of vacuum mechatronics is growing with an increased application of vacuum in space studies and in manufacturing for material processing, medicine, microelectronics, emission studies, lyophylisation, freeze drying and packaging. The quickly developing field of vacuum mechatronics will also be the driving force for the realization of an advanced era of totally enclosed clean manufacturing cells. High technology manufacturing has increasingly demanding requirements for precision manipulation, in situ process monitoring and contamination-free environments. To remove the contamination problems associated with human workers, the tendency in many manufacturing processes is to move towards total automation. This will become a requirement in the near future for e.g., microelectronics manufacturing. Automation in ultra-clean manufacturing environments is evolving into the concept of self-contained and fully enclosed manufacturing. A Self Contained Automated Robotic Factory (SCARF) is being developed as a flexible research facility for totally enclosed manufacturing. The construction and successful operation of a SCARF will provide a novel, flexible, self-contained, clean, vacuum manufacturing environment. SCARF also requires very high reliability and intelligent control. The trends in vacuum mechatronics and some of the key research issues are reviewed.

  15. Contrast-Enhanced Ultrasound Improves the Pathological Outcomes of US-Guided Core Needle Biopsy That Targets the Viable Area of Anterior Mediastinal Masses

    PubMed Central

    Zhou, Jian-hua; Shan, Hong-bo; Ou, Wei; Mo, Yun-xian; Xiang, Jin; Wang, Yu; Wang, Si-yu

    2018-01-01

    Based on the option that ultrasound-guided core needle biopsy (US-CNB) of the enhanced portion of anterior mediastinal masses (AMMs) identified by contrast-enhanced ultrasound (CEUS) would harvest viable tissue and benefit the histological diagnoses, a retrospective study was performed to elucidate the correlation between the prebiopsy CEUS and diagnostic yield of AMMs and found that CEUS potentially improved the diagnostic yield of AMMs compared with conventional US with a significant increase in the cellularity of samples. Furthermore, the marginal blood flow signals and absence of necrosis can predict the diagnostic yield of AMM. It was concluded that US-CNB of the viable part of AMMs, as verified by CEUS, was able to harvest sufficient tissue with more cellularity that could be used for ancillary studies and improve the diagnostic yield. And CEUS was recommended to those patients with AMMs undergoing repeated US-CNB, with the absence of marginal blood signals or presence of necrosis. PMID:29581992

  16. Clinical application of Lin's biopsy grasper for intrauterine targeted biopsy and polypectomy during office hysteroscopy.

    PubMed

    Cheng, Hsin-Yi; Lin, Bao-Liang; Tseng, Jen-Yu; Ueno, Kazunori; Nakada, Sakura

    2018-06-01

    Hysteroscopy has widely been used for diagnosis of the uterine cavity; however, target biopsy has often been difficult in part to the inherent limitations of ancillary instruments. Lin's biopsy grasper was specifically designed to work in conjunction with a flexible hysteroscope to obtain intrauterine biopsy under transabdominal sonography. Herein, we share our clinical experience in the management of endometrial abnormalities with the use of Lin's biopsy grasper during office-based hysteroscopy. From February 2006 to November 2016, the use of Lin's biopsy grasper for tissue biopsy was attempted on 126 cases. We retrospectively recorded and analyzed the patients' preoperative characteristics and biopsy outcomes to demonstrate the feasibility and efficacy of Lin's biopsy grasper. Out of the one hundred and twenty-six enrolled patients, satisfactory targeted biopsies were achieved; including high diagnostic rate (92.1%, with 116 cases confirmed histologically) and adequate tissue retrieval (77.8%, with 98 cases obtaining optimal specimen volume). All patients tolerated the procedure without analgesics or anesthesia. Diagnostic flexible hysteroscopy combined with the use of Lin's biopsy grasper has proven to be an effective tool for intrauterine evaluation and obtaining tissue sample. Copyright © 2018. Published by Elsevier B.V.

  17. Natural vacuum electronics

    NASA Technical Reports Server (NTRS)

    Leggett, Nickolaus

    1990-01-01

    The ambient natural vacuum of space is proposed as a basis for electron valves. Each valve is an electron controlling structure similiar to a vacuum tube that is operated without a vacuum sustaining envelope. The natural vacuum electron valves discussed offer a viable substitute for solid state devices. The natural vacuum valve is highly resistant to ionizing radiation, system generated electromagnetic pulse, current transients, and direct exposure to space conditions.

  18. Predicting the risk of patients with biopsy Gleason score 6 to harbor a higher grade cancer.

    PubMed

    Gofrit, Ofer N; Zorn, Kevin C; Taxy, Jerome B; Lin, Shang; Zagaja, Gregory P; Steinberg, Gary D; Shalhav, Arieh L

    2007-11-01

    Prostate cancer Gleason score 3 + 3 = 6 is currently the most common score assigned on prostatic biopsies. We analyzed the clinical variables that predict the likelihood of a patient with biopsy Gleason score 6 to harbor a higher grade tumor. The study population consisted of 448 patients with a mean age of 59.1 years who underwent radical prostatectomy between February 2003 to October 2006 for Gleason score 6 adenocarcinoma. The effect of preoperative variables on the probability of a Gleason score upgrade on final pathological evaluation was evaluated using logistic regression, and classification and regression tree analysis. Gleason score upgrade was found in 91 of 448 patients (20.3%). Logistic regression showed that only serum prostate specific antigen and the greatest percent of cancer in a core were significantly associated with a score upgrade (p = 0.0014 and 0.023, respectively). Classification and regression tree analysis showed that the risk of a Gleason score upgrade was 62% when serum prostate specific antigen was higher than 12 ng/ml and 18% when serum prostate specific antigen was 12 ng/ml or less. In patients with serum prostate specific antigen lower than 12 ng/ml the risk of a score upgrade could be dichotomized at a greatest percent of cancer in a core of 5%. The risk was 22.6% and 10.5% when the greatest percent of cancer in a core was higher than 5% and 5% or lower, respectively. The probability of patients with a prostate biopsy Gleason score of 6 to conceal a Gleason score of 7 or higher can be predicted using serum prostate specific antigen and the greatest percent of cancer in a core. With these parameters it is possible to predict upgrade rates as high as 62% and as low as 10.5%.

  19. FNA, core biopsy, or both for the diagnosis of lung carcinoma: Obtaining sufficient tissue for a specific diagnosis and molecular testing.

    PubMed

    Coley, Shana M; Crapanzano, John P; Saqi, Anjali

    2015-05-01

    Increasingly, minimally invasive procedures are performed to assess lung lesions and stage lung carcinomas. In cases of advanced-stage lung cancer, the biopsy may provide the only diagnostic tissue. The aim of this study was to determine which method-fine-needle aspiration (FNA), core biopsy (CBx), or both (B)--is optimal for providing sufficient tissue for rendering a specific diagnosis and pursuing molecular studies for guiding tumor-specific treatment. A search was performed for computed tomography-guided lung FNA, CBx, or B cases with rapid onsite evaluation. Carcinomas were assessed for the adequacy to render a specific diagnosis; this was defined as enough refinement to subtype a primary carcinoma or to assess a metastatic origin morphologically and/or immunohistochemically. In cases of primary lung adenocarcinoma, the capability of each modality to yield sufficient tissue for molecular studies (epidermal growth factor receptor, KRAS, or anaplastic lymphoma kinase) was also assessed. There were 210 cases, and 134 represented neoplasms, including 115 carcinomas. For carcinomas, a specific diagnosis was reached in 89% of FNA cases (33 of 37), 98% of CBx cases (43 of 44), and 100% of B cases (34 of 34). For primary lung adenocarcinomas, adequate tissue remained to perform molecular studies in 94% of FNA cases (16 of 17), 100% of CBx cases (19 of 19), and 86% of B cases (19 of 22). No statistical difference was found among the modalities for either reaching a specific diagnosis (p = .07, Fisher exact test) or providing sufficient tissue for molecular studies (p = .30, Fisher exact test). The results suggest that FNA, CBx, and B are comparable for arriving at a specific diagnosis and having sufficient tissue for molecular studies: they specifically attained the diagnostic and prognostic goals of minimally invasive procedures for lung carcinoma. © 2015 American Cancer Society.

  20. Estimation of sensing characteristics for refractory nitrides based gain assisted core-shell plasmonic nanoparticles

    NASA Astrophysics Data System (ADS)

    Shishodia, Manmohan Singh; Pathania, Pankaj

    2018-04-01

    Refractory transition metal nitrides such as zirconium nitride (ZrN), hafnium nitride (HfN) and titanium nitride (TiN) have emerged as viable alternatives to coinage metals based plasmonic materials, e.g., gold (Au) and silver (Ag). The present work assesses the suitability of gain assisted ZrN-, HfN- and TiN-based conventional core-shell nanoparticles (CCSNPs) and multilayered core-shell nanoparticles (MCSNPs) for refractive index sensing. We report that the optical gain incorporation in the dielectric layer leads to multifold enhancement of the scattering efficiency (Qsca), substantial reduction of the spectral full width at half maximum, and a higher figure of merit (FOM). In comparison with CCSNPs, the MCSNP system exhibits superior sensing characteristics such as higher FOM, ˜ 45% reduction in the critical optical gain, response shift towards the biological window, and higher degree of tunability. Inherent biocompatibility, growth compatibility, chemical stability and flexible spectral tuning of refractory nitrides augmented by superior sensing properties in the present work may pave the way for refractory nitrides based low cost sensing.

  1. Self-assembly of core-shell structure PtO2@Pt nanodots and their formation evolution

    NASA Astrophysics Data System (ADS)

    Yang, Weijia; Liu, Junjie; Liu, Mingquan; Zhao, Zhicheng; Song, Yapeng; Tang, Xiufeng; Luo, Jianyi; Zeng, Qingguang; He, Xin

    2018-05-01

    Core-shell structure PtO2@Pt nanodots have been self-assembly by vacuum sputtering and high temperature annealing. First, Pt thin films with a small amount of PtO2 are grown on the sapphire substrates by vacuum sputtering. And then high temperature annealing on the thin films is carried out at 800 °C for 2 min to form Pt nanodots. During the cooling process, the atmosphere is deployed to supplant the nitrogen. Finally, even distributed core-shell structure PtO2@Pt nanodots with a diameter from 100 to 300 nm are achieved. Furthermore, the formation evolution of core-shell structure PtO2@Pt nanodots is also proposed. This work open up a new approach for fabricating core-shell structure nanodots.

  2. VACUUM TRAP

    DOEpatents

    Gordon, H.S.

    1959-09-15

    An improved adsorption vacuum trap for use in vacuum systems was designed. The distinguishing feature is the placement of a plurality of torsionally deformed metallic fins within a vacuum jacket extending from the walls to the central axis so that substantially all gas molecules pass through the jacket will impinge upon the fin surfaces. T fins are heated by direct metallic conduction, thereby ol taining a uniform temperature at the adeorbing surfaces so that essentially all of the condensible impurities from the evacuating gas are removed from the vacuum system.

  3. Midkine and pleiotrophin concentrations in needle biopsies of breast and lung masses.

    PubMed

    Giamanco, Nicole M; Jee, Youn Hee; Wellstein, Anton; Shriver, Craig D; Summers, Thomas A; Baron, Jeffrey

    2017-09-07

    Midkine (MDK) and pleiotrophin (PTN) are two closely related heparin-binding growth factors which are overexpressed in a wide variety of human cancers. We hypothesized that the concentrations of these factors in washout of biopsy needles would be higher in breast and lung cancer than in benign lesions. Seventy subjects underwent pre-operative core needle biopsies of 78 breast masses (16 malignancies). In 11 subjects, fine needle aspiration was performed ex vivo on 7 non-small cell lung cancers and 11 normal lung specimens within surgically excised lung tissue. The biopsy needle was washed with buffer for immunoassay. The MDK/DNA and the PTN/DNA ratio in most of the malignant breast masses were similar to the ratios in benign masses except one lobular carcinoma in situ (24-fold higher PTN/DNA ratio than the average benign mass). The MDK/DNA and PTN/DNA ratio were similar in most malignant and normal lung tissue except one squamous cell carcinoma (38-fold higher MDK/DNA ratio than the average of normal lung tissue). Both MDK and PTN are readily measurable in washout of needle biopsy samples from breast and lung masses and levels are highly elevated only in a specific subset of these malignancies.

  4. Comparative cost-effectiveness of fine needle aspiration biopsy versus image-guided biopsy, and open surgical biopsy in the evaluation of breast cancer in the era of Affordable Care Act: a changing landscape.

    PubMed

    Masood, Shahla; Rosa, Marilin; Kraemer, Dale F; Smotherman, Carmen; Mohammadi, Amir

    2015-08-01

    Proven as a time challenged and cost-effective sampling procedure, the use of FNAB has still remained controversial among the scientific community. Currently, other minimally invasive sampling procedures such as ultrasound guided fine needle aspiration biopsy (US-FNAB) and image guided core needle biopsy (IG-CNB) have become the preferred sampling procedures for evaluation of breast lesions. However, changes in the medical economy and the current growing emphasis on cost containment in the era of the Affordable Care Act make it necessary to stimulate a renewed interest in the use of FNAB as the initial diagnostic sampling procedure. This study was designed to define the changing trend in the practice of tissue sampling during the last several years, and to assess the comparative effectiveness and appropriateness of the procedure of choice for breast cancer diagnosis. After Institutional Review Board (IRB) approval, the computer database of the Pathology Department, University of Florida, College of Medicine-Jacksonville at UF Health was retrospectively searched to identify all breast biopsy pathology reports issued during the period of January 2004 to December 2011. The inclusion criteria were all women that underwent any of the following biopsy types: FNAB, US-FNAB, IG-CNB, and surgical biopsy (SB). Diagnostic procedures were identified using current procedural terminology (CPT) codes recorded on claims from the UF Health Jacksonville patient accounting application files. The data obtained was used to determine which technique has the best cost-effectiveness in the diagnosis of breast cancer. The outcome variable for this project was a positive breast cancer diagnosis resulting from these methodologies. The predictor variable was the biopsy type used for sampling. The rate of cancer detection for each procedure was also determined. Among the four groups of procedures compared, the lower cost was attributed to FNAB, followed by US-FNAB, and SB. IG-CNB was the most

  5. Ultrasound-guided chest biopsies.

    PubMed

    Middleton, William D; Teefey, Sharlene A; Dahiya, Nirvikar

    2006-12-01

    Pulmonary nodules that are surrounded by aerated lung cannot be visualized with sonography. Therefore, percutaneous biopsy must be guided with computed tomography or fluoroscopy. Although this restriction only applies to central lung nodules, it has permeated referral patterns for other thoracic lesions and has retarded the growth of ultrasound-guided interventions. Nevertheless, sonography is an extremely flexible modality that can expeditiously guide many biopsy procedures in the thorax. Peripheral pulmonary nodules can be successfully biopsied with success rates exceeding 90% and complications rates of less than 5%. Orienting the probe parallel to the intercostal space facilitates biopsies of peripheral pulmonary nodules. Anterior mediastinal masses that extend to the parasternal region are often easily approachable provided the internal mammary vessels, costal cartilage, and deep great vessels are identified and avoided. Superior mediastinal masses can be sampled from a suprasternal or supraclavicular approach. Phased array probes or tightly curved arrays may provide improved access for biopsies in this location. Posterior mediastinal masses are more difficult to biopsy with ultrasound guidance because of the overlying paraspinal muscles. However, when posterior mediastinal masses extend into the posterior medial pleural region, they can be biopsied with ultrasound guidance. Because many lung cancers metastasize to the supraclavicular nodes, it is important to evaluate the supraclavicular region when determining the best approach to obtain a tissue diagnosis. When abnormal supraclavicular nodes are present, they often are the easiest and safest lesions to biopsy.

  6. [Non-invasive assessment of the perfusion of wounds using power Doppler imaging: vacuum assisted closure versus direct wound closure].

    PubMed

    Jungius, K P; Chilla, B K; Labler, L; Teodorovic, N; Marincek, B

    2006-10-01

    The goal of our study was to assess the perfusion in wounds treated by vacuum assisted closure (VAC) compared to primary wound closure. Power Doppler Ultrasound (PDUS) was carried out under standardised conditions in 15 VAC-treated and 10 primarily closed wounds as well as on altogether 25 intraindividual reference areas. All data were sent to a work station for post-processing to determine the perfused area. Statistical data analysis was performed with the Mann-Whitney test. Both VAC-treated wounds and primarily closed wounds showed a significant increase of the perfusion when compared to the intraindividual reference area (p < 0.0001). In VAC-treated wounds, a markedly increased perfusion was measured compared to the wounds closed primarily (p < 0.0001). Perfusion decreased during treatment, but in two VAC-treated wounds, an initial increase of the perfusion was observed. Both these wounds were grossly infected. PDUS allows the quantification of the differences in wound perfusion. This can be helpful in the detection of progressive local wound infections.

  7. Issues and challenges associated with classifying neoplasms in percutaneous needle biopsies of incidentally found small renal masses.

    PubMed

    Evans, Andrew J; Delahunt, Brett; Srigley, John R

    2015-03-01

    Percutaneous needle core biopsy has become acceptable for classifying renal tumours and guiding patient management in the setting of an incidentally-detected small renal mass (SRM), defined as an asymptomatic, non-palpable mass <4cm in maximum dimension. Long-held concerns preventing the incorporation of biopsies into routine patient care, including the perception of poor diagnostic yield and risks of complications such as bleeding or biopsy tract seeding, have largely been disproven. While needle biopsies for SRMs have traditionally been performed in academic centres, pathologists based in non-academic centres can expect to encounter these specimens as urologists and/or interventional radiologist trainees complete their training programs and begin work in non-academic centres. This review covers the rationale for performing these biopsies, the expected diagnostic yield, relevant differential diagnoses and an approach to classifying SRMs based on limited samples as well as the use of immunohistochemical (IHC) staining panels to aid in this process. There is also an undeniable learning curve for pathologists faced with reporting these biopsies and a number of issues and potential pitfalls attributable to sampling must be kept in mind by pathologists and clinicians alike. Copyright © 2015 Elsevier Inc. All rights reserved.

  8. Clinical validation of an epigenetic assay to predict negative histopathological results in repeat prostate biopsies.

    PubMed

    Partin, Alan W; Van Neste, Leander; Klein, Eric A; Marks, Leonard S; Gee, Jason R; Troyer, Dean A; Rieger-Christ, Kimberly; Jones, J Stephen; Magi-Galluzzi, Cristina; Mangold, Leslie A; Trock, Bruce J; Lance, Raymond S; Bigley, Joseph W; Van Criekinge, Wim; Epstein, Jonathan I

    2014-10-01

    The DOCUMENT multicenter trial in the United States validated the performance of an epigenetic test as an independent predictor of prostate cancer risk to guide decision making for repeat biopsy. Confirming an increased negative predictive value could help avoid unnecessary repeat biopsies. We evaluated the archived, cancer negative prostate biopsy core tissue samples of 350 subjects from a total of 5 urological centers in the United States. All subjects underwent repeat biopsy within 24 months with a negative (controls) or positive (cases) histopathological result. Centralized blinded pathology evaluation of the 2 biopsy series was performed in all available subjects from each site. Biopsies were epigenetically profiled for GSTP1, APC and RASSF1 relative to the ACTB reference gene using quantitative methylation specific polymerase chain reaction. Predetermined analytical marker cutoffs were used to determine assay performance. Multivariate logistic regression was used to evaluate all risk factors. The epigenetic assay resulted in a negative predictive value of 88% (95% CI 85-91). In multivariate models correcting for age, prostate specific antigen, digital rectal examination, first biopsy histopathological characteristics and race the test proved to be the most significant independent predictor of patient outcome (OR 2.69, 95% CI 1.60-4.51). The DOCUMENT study validated that the epigenetic assay was a significant, independent predictor of prostate cancer detection in a repeat biopsy collected an average of 13 months after an initial negative result. Due to its 88% negative predictive value adding this epigenetic assay to other known risk factors may help decrease unnecessary repeat prostate biopsies. Copyright © 2014 American Urological Association Education and Research, Inc. Published by Elsevier Inc. All rights reserved.

  9. A technological advance for 21st century obstetricians: the electronically-controlled vacuum extractor.

    PubMed

    Perone, Nicola

    2018-04-25

    To describe an innovative electronically-controlled vacuum extractor (VE) in detail and to illustrate its performance characteristics, as observed in a laboratory study. Thirty simulated, vacuum-assisted deliveries. (1) The ability to measure in real-time of the pull applied and to sound an alert, when the traction approaches the negative pressure under the cup, to prevent its detachment. (2) The recording and printing of a graphic representation of the pull applied (vacuum delivery graph). (3) The emission of a warning signal when the 15-min time limit of continuous cup application on the fetal scalp, is reached. No cup detachment occurred in any of the 15 vacuum-assisted deliveries, in which traction was kept below the adhesive force of the cup [44 lb (20 kg)], except in three cases, due to loss of negative pressure. In the remaining 15 tests, in which traction was greater than the adhesive force of the cup, "pull-offs" inevitably occurred. Furthermore, upon reaching the 15-min time limit of continuous cup application on the fetal cephalic model, a warning signal was emitted, as programmed. Conclusions We demonstrated that the electronically-controlled VE, with its distinctive pull-sensing handle, performs suitably for its intended purposes. The ability of the modernized device to decrease the incidence of cup detachment, secondary to the inadvertent application of excessive traction, may result in considerable safety, medico-legal and didactic advantages.

  10. THERAPEUTIC STRATEGY FOR GRANULOMATOUS LOBULAR MASTITIS: A CLINICOPATHOLOGICAL STUDY OF 12 PATIENTS

    PubMed Central

    AKAHANE, KAZUHISA; TSUNODA, NOBUYUKI; KATO, MASAMICHI; NODA, SUMIYO; SHIMOYAMA, YOSHIE; ISHIGAKI, SATOKO; SATAKE, HIROKO; NAKAMURA, SHIGEO; NAGINO, MASATO

    2013-01-01

    ABSTRACT Granulomatous lobular mastitis (GLM) is a rare inflammatory pseudotumor. No therapeutic modality for this disease has been established because of its rarity. The purpose of this study is to evaluate the treatment strategies of GLM. Twelve women who met the histological criteria for GLM were retrospectively studied. The clinical data and the presentation, histopathology, and management of the disease were analyzed by reviewing the patients’ medical records. The diagnosis of GLM was confirmed histologically by core needle biopsy in 9 cases, by vacuum-assisted biopsy in 2 cases, and by excisional biopsy in 1 case. Ten patients received corticosteroid treatment and another two patients were treated with local excision or incision and drainage. The median initial dosage of corticosteroid (Prednisolone) was 30 mg/day (range: 15–60 mg/day), and the dosages were tapered according to improvement. The median duration of corticosteroid treatment was 5 months (range: 1–12 months). The median follow-up period was 22 months (range: 6–104 months), and no patient treated with corticosteroid demonstrated recurrence. However, patients treated with excision or incision and drainage had recurrences. These results suggest that steroid treatment may be the first choice in treatment strategies for GLM. PMID:24640175

  11. BEM-based simulation of lung respiratory deformation for CT-guided biopsy.

    PubMed

    Chen, Dong; Chen, Weisheng; Huang, Lipeng; Feng, Xuegang; Peters, Terry; Gu, Lixu

    2017-09-01

    Accurate and real-time prediction of the lung and lung tumor deformation during respiration are important considerations when performing a peripheral biopsy procedure. However, most existing work focused on offline whole lung simulation using 4D image data, which is not applicable in real-time image-guided biopsy with limited image resources. In this paper, we propose a patient-specific biomechanical model based on the boundary element method (BEM) computed from CT images to estimate the respiration motion of local target lesion region, vessel tree and lung surface for the real-time biopsy guidance. This approach applies pre-computation of various BEM parameters to facilitate the requirement for real-time lung motion simulation. The resulting boundary condition at end inspiratory phase is obtained using a nonparametric discrete registration with convex optimization, and the simulation of the internal tissue is achieved by applying a tetrahedron-based interpolation method depend on expert-determined feature points on the vessel tree model. A reference needle is tracked to update the simulated lung motion during biopsy guidance. We evaluate the model by applying it for respiratory motion estimations of ten patients. The average symmetric surface distance (ASSD) and the mean target registration error (TRE) are employed to evaluate the proposed model. Results reveal that it is possible to predict the lung motion with ASSD of [Formula: see text] mm and a mean TRE of [Formula: see text] mm at largest over the entire respiratory cycle. In the CT-/electromagnetic-guided biopsy experiment, the whole process was assisted by our BEM model and final puncture errors in two studies were 3.1 and 2.0 mm, respectively. The experiment results reveal that both the accuracy of simulation and real-time performance meet the demands of clinical biopsy guidance.

  12. Peripheral Synucleinopathy in Early Parkinson’s Disease: Submandibular Gland Needle Biopsy Findings

    PubMed Central

    Adler, Charles H.; Dugger, Brittany N.; Hentz, Joseph G.; Hinni, Michael L.; Lott, David G.; Driver-Dunckley, Erika; Mehta, Shyamal; Serrano, Geidy; Sue, Lucia I.; Duffy, Amy; Intorcia, Anthony; Filon, Jessica; Pullen, Joel; Walker, Douglas G.; Beach, Thomas G.

    2015-01-01

    Background Finding a peripheral tissue biopsy site to diagnose early Parkinson’s disease would be of value for clinical care, biomarker validation, and as research enrollment criteria. While autopsy and advanced Parkinson’s disease studies suggest submandibular gland is an important biopsy site, there are no studies in early Parkinson’s disease. Objectives Determine whether needle biopsy of the submandibular gland reveals Lewy type α-synucleinopathy in early Parkinson’s disease. Methods Twenty-five early Parkinson’s disease (duration < 5 years) and 10 controls underwent transcutaneous needle core biopsies of the submandibular gland. Tissue was stained for phosphorylated α-synuclein, reviewed blind to clinical diagnosis, and only nerve element staining was considered positive. Results Mean (Standard Deviation) age 69.5 (8.3) for Parkinson’s disease group, 64.8 (8.0) years for controls, and disease duration 2.6 (1.1) years. Six Parkinson’s disease and one control subject had inadequate glandular tissue. Positive staining was found in 14/19 (74%) Parkinson’s disease and 2/9 (22%) control subjects. Parkinson’s disease positive and negative cases did not differ clinically. Adverse events (mainly swelling and bruising) were common (77% of cases), but were minor and transient. Conclusions Submandibular gland needle biopsies identified phosphorylated α-synuclein staining in 74% of early Parkinson’s disease subjects. False positives may be true false positives or may represent prodromal Parkinson’s disease. If confirmed in larger studies with eventual autopsy confirmation, the potential value of submandibular gland biopsies for early Parkinson’s disease may be to aid in clinical trial inclusion/exclusion and eventually serve as a gold standard for biomarker studies short of autopsy confirmation. PMID:26799362

  13. Incidence of major hemorrhage after aggressive image-guided liver mass biopsy in the era of individualized medicine.

    PubMed

    Boyum, James H; Atwell, Thomas D; Wall, Darci J; Mansfield, Aaron S; Kerr, Sarah E; Gunderson, Tina M; Rumilla, Kandelaria M; Weisbrod, Adam J; Kurup, A Nicholas

    2018-05-17

    To analyze a large volume of image-guided liver mass biopsies to assess for an increased incidence of major hemorrhage after aggressive liver mass sampling, and to determine if coaxial technique reduces major hemorrhage rate. Patients who underwent image-guided liver mass biopsy over a 15-year period (December 7, 2001-September 22, 2016) were retrospectively identified. An aggressive biopsy was defined as a biopsy event in which ≥ 4 core needle passes were performed. Association of major hemorrhage after aggressive liver mass biopsy and other potential risk factors of interest were assessed using logistic regression analysis. For the subset of aggressive biopsies, Fisher's exact test was used to compare the incidence of major hemorrhage using coaxial versus noncoaxial techniques. Aggressive biopsies constituted 11.6% of biopsy events (N =579/5011). The incidence of major hemorrhage with <4 passes was 0.4% (N =18/4432) and with ≥4 passes 1.2% (N =6/579). In univariable models, aggressive biopsy was significantly associated with major hemorrhage (OR 3.0, 95% CI 1.16-6.92, p =0.025). After adjusting for gender and platelet count, the association was not significant at the p =0.05 level (OR 2.58, 95% CI 0.927-6.24, p =0.067). The rate of major hemorrhage in the coaxial biopsy technique group was 1.4% (N =3/209) compared to 1.1% (N =4/370) in the noncoaxial biopsy technique group, which was not a significant difference (p =0.707). Although aggressive image-guided liver mass biopsies had an increased incidence of major hemorrhage, the overall risk of bleeding remained low. The benefit of such biopsies will almost certainly outweigh the risk in most patients.

  14. Use of sentinel lymph node biopsy to select patients for local–regional therapy after neoadjuvant chemotherapy

    PubMed Central

    Erdahl, Lillian M.; Boughey, Judy C.

    2014-01-01

    Use of sentinel lymph node biopsy for axillary staging of patients with breast cancer treated with neoadjuvant chemotherapy has been widely debated. Questions arise regarding the accuracy of sentinel lymph node biopsy in axillary staging for these patients and its use to determine further local–regional therapy, including surgery and radiation therapy. For patients who are clinically node-negative at presentation, sentinel lymph node biopsy enables accurate staging of the axilla after neoadjuvant chemotherapy, and determination of which patients should go on to further axillary surgery and regional nodal radiation therapy. Importantly, performing axillary staging after completion of chemotherapy, rather than before chemotherapy, enables assessment of response to chemotherapy and the extent of residual disease. This information can assist the planning of adjuvant treatment. Recent data indicate that sentinel node biopsy can also be used to assess disease response after neoadjuvant chemotherapy for patients with clinical N1 disease at presentation. PMID:24683440

  15. Efficacy and economic impact evaluation of a navigation system for assisted lung biopsy

    PubMed Central

    Giannatiempo, Sara; Petitti, Tommasangelo; Zobel, Bruno B.; Grasso, Rosario F.; Guglielmelli, Eugenio

    2018-01-01

    This Letter reports on the testing and assessment of an optical computed tomography-navigation system for percutaneous lung interventional, SIRIO, showing how the lesion diameter affects the bioptic procedure. Clinical data, relating to 501 patients, were collected at the Department of Interventional Radiology of Policlinico Universitario Campus Bio-Medico. This Letter shows that the diameter of lesion affects only the procedure duration (50.91 ± 18.87 min for lesions of diameter ≤20 mm and 44.98 ± 19.43 min for lesions of diameter >20 and ≤40 mm). For the nodules with a diameter ≤20 mm, there is a significant increase in the duration of the procedure (for each mm less the time increases by 6 s). Other parameters like the mean effective radiation dose and the presence of a diagnostic or non-diagnostic specimen do not depend, instead, on the lesion size. The economic analysis based on the biopsy procedure with SIRIO shows the necessity to adopt a new reimbursement system for percutaneous biopsy performed using navigation systems to stimulate their use to get important non-economic gains such as early diagnosis, reduction of the absorbed dose of X-rays and increasing number of lung cancers in a curable early stage. PMID:29750112

  16. Efficacy and economic impact evaluation of a navigation system for assisted lung biopsy.

    PubMed

    Giannatiempo, Sara; Carpino, Giorgio; Petitti, Tommasangelo; Zobel, Bruno B; Grasso, Rosario F; Guglielmelli, Eugenio

    2018-04-01

    This Letter reports on the testing and assessment of an optical computed tomography-navigation system for percutaneous lung interventional, SIRIO, showing how the lesion diameter affects the bioptic procedure. Clinical data, relating to 501 patients, were collected at the Department of Interventional Radiology of Policlinico Universitario Campus Bio-Medico. This Letter shows that the diameter of lesion affects only the procedure duration (50.91 ± 18.87 min for lesions of diameter ≤20 mm and 44.98 ± 19.43 min for lesions of diameter >20 and ≤40 mm). For the nodules with a diameter ≤20 mm, there is a significant increase in the duration of the procedure (for each mm less the time increases by 6 s). Other parameters like the mean effective radiation dose and the presence of a diagnostic or non-diagnostic specimen do not depend, instead, on the lesion size. The economic analysis based on the biopsy procedure with SIRIO shows the necessity to adopt a new reimbursement system for percutaneous biopsy performed using navigation systems to stimulate their use to get important non-economic gains such as early diagnosis, reduction of the absorbed dose of X-rays and increasing number of lung cancers in a curable early stage.

  17. Percutaneous Biopsy of Osteoid Osteomas Prior to Percutaneous Treatment Using Two Different Biopsy Needles

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Laredo, Jean-Denis, E-mail: jean-denis.laredo@lrb.aphp.fr; Hamze, Bassam; Jeribi, Riadh

    2009-09-15

    Biopsy is usually performed as the first step in percutaneous treatment of osteoid osteomas prior to laser photocoagulation. At our institution, 117 patients with a presumed diagnosis of osteoid osteoma had a trephine biopsy before a percutaneous laser photocoagulation. Biopsies were made using two different types of needles. A Bonopty biopsy needle (14-gauge cannula, 16-gauge trephine needle; Radi Medical Systems, Uppsala, Sweden) was used in 65 patients, and a Laurane biopsy needle (11-gauge cannula, 12.5-gauge trephine needle; Laurane Medical, Saint-Arnoult, France) in 43 patients. Overall biopsy results were positive for osteoid osteoma in 83 (70.9%) of the 117 cases. Themore » Laurane needle provided a significantly higher positive rate (81.4%) than the Bonopty needle (66.1%; p < 0.05). This difference was not due to the size of the nidus, which was similar in the two groups (p < 0.05) and may be an effect of differences in needle caliber (12.5 vs. 14 gauge) as well as differences in needle design. The rate of positive biopsy results obtained in the present series with the Laurane biopsy needle is, to our knowledge, the highest rate reported in series dealing with percutaneous radiofrequency ablation and laser photocoagulation of osteoid osteomas.« less

  18. 78 FR 66932 - Scientific Information Request on Core Needle and Open Surgical Biopsy for Diagnosis of Breast...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-11-07

    ... conducting this comparative effectiveness review pursuant to Section 1013 of the Medicare Prescription Drug... biopsy technique (each index test) will be quantified versus the reference standard \\b\\. The comparative...

  19. 7 to 10 years' follow-up of 573 patients with elevated prostate-specific antigen (>4 ng/mL) or/and suspected rectal examination: biopsies protocol and follow-up guides.

    PubMed

    Kravchick, Sergey; Cytron, Shmuel; Stepnov, Eugeny; Ben-Dor, David; Kravchenko, Yakov; Peled, Ronit

    2009-06-01

    In this study, we tried to design a scheme for performing transrectal ultrasonographic (TRUS)-biopsies that would be accurate and include the optimal number of cores. We included in this study 600 consecutive patients with suspicious findings on a per-rectum examination and/or an elevated prostate-specific antigen (PSA) (>4 ng/mL) level. Patients were followed for 7 to 10 years. In all patients, we took from 8 to 16 biopsy samples, according to the prostate volume, from the lateral aspects. In the second session, the biopsy samples were taken medially; in the third session, we included the transitional zone, while in consecutive sessions, we increased the number of cores from all areas. Only 573 of the patients remained in follow-up. TRUS-biopsy detected prostate cancer (PCa) in 257 patients (44.85% overall detection rate). The detection rate in the first and second sessions was 32.98% and 14.94%, respectively, reaching 13.2% and 2.17%, in the third and fourth sessions, respectively. Prostate volumes were significantly smaller (52.9 +/- 22.4 cc vs 58.9 +/- 23.8 cc, P < 0.002) and the PSA/adenoma/prostate volumes ratio (ad-pro) ratio was higher (18.3 +/- 9 vs 13.96, P < 0/001) in the patients with PCa. Patients with PCa underwent fewer biopsy procedures and biopsy sessions than patients without a diagnosis of PCa (14.9 +/- 8.9 vs 20.4 +/- 12, P < 0.001;1.3 +/- 0.6 vs 1.7 +/- 0.9, P < 0.001). Biopsy samples obtained from the base were positive for cancer only in larger prostates with a mean volume of 54.3 +/- 15.3 cc. Numbers of biopsy procedures and PSA/ad-pro ratio were the strongest predictive factors for PCa detection (P < 0.001). In patients with a prostate volume >or=53 cc and PSA/ad-pro ratio >or=18, the optimal biopsy cores should be >or=15. Using this scheme, the discontinuation of biopsy procedures might be considered after three consecutive sessions.

  20. Determination of transformation products of unsymmetrical dimethylhydrazine in water using vacuum-assisted headspace solid-phase microextraction.

    PubMed

    Orazbayeva, Dina; Kenessov, Bulat; Psillakis, Elefteria; Nassyrova, Dayana; Bektassov, Marat

    2018-06-22

    A new, sensitive and simple method based on vacuum-assisted headspace solid-phase microextraction (Vac-HSSPME) followed by gas chromatography-mass-spectrometry (GC-MS), is proposed for the quantification of rocket fuel unsymmetrical dimethylhydrazine (UDMH) transformation products in water samples. The target transformation products were: pyrazine, 1-methyl-1H-pyrazole, N-nitrosodimethylamine, N,N-dimethylformamide, 1-methyl-1Н-1,2,4-triazole, 1-methyl-imidazole and 1H-pyrazole. For these analytes and within shorter sampling times, Vac-HSSPME yielded detection limits (0.5-100 ng L -1 ) 3-10 times lower than those reported for regular HSSPME. Vac-HSSPME sampling for 30 min at 50 °C yielded the best combination of analyte responses and their standard deviations (<15%). 1-Formyl-2,2-dimethylhydrazine and formamide were discarded because of the poor precision and accuracy when using Vac-HSSPME. The recoveries for the rest of the analytes ranged between 80 and 119%. The modified Mininert valve and Thermogreen septum could be used for automated extraction as it ensured stable analyte signals even after long waiting times (>24 h). Finally, multiple Vac-HSSME proved to be an efficient tool for controlling the matrix effect and quantifying UDMH transformation products. Copyright © 2018 Elsevier B.V. All rights reserved.