Fernández-García, P; Marco-Doménech, S F; Lizán-Tudela, L; Ibáñez-Gual, M V; Navarro-Ballester, A; Casanovas-Feliu, E
To determine the cost effectiveness of breast biopsy by 9G vacuum-assisted guided by vertical stereotaxy or ultrasonography in comparison with breast biopsy by 14G core-needle biopsy and surgical biopsy. We analyzed a total of 997 biopsies (181 vacuum-assisted, 626 core, and 190 surgical biopsies). We calculated the total costs (indirect and direct) of the three types of biopsy. We did not calculate intangible costs. We measured the percentage of correct diagnoses obtained with each technique. To identify the most cost-effective option, we calculated the mean ratios for the three types of biopsies. Total costs were €225.09 for core biopsy, €638.90 for vacuum-assisted biopsy, and €1780.01 for surgical biopsy. The overall percentage of correct diagnoses was 91.81% for core biopsy, 94.03% for vacuum-assisted biopsy, and 100% for surgical biopsy; however, these differences did not reach statistical significance (p=0.3485). For microcalcifications, the percentage of correct diagnoses was 50% for core biopsy and 96.77% for vacuum-assisted biopsy (p<0.0001). For nodules, there were no significant differences among techniques. The mean cost-effectiveness ratio considering all lesions was 2.45 for core biopsy, 6.79 for vacuum-assisted biopsy, and 17.80 for surgical biopsy. Core biopsy was the dominant option for the diagnosis of suspicious breast lesions in general. However, in cases with microcalcifications, the low percentage of correct diagnoses achieved by core biopsy (50%) advises against its use in this context, where vacuum-assisted biopsy would be the technique of choice because it is more cost-effective than surgical biopsy, the other technique indicated for biopsying microcalcifications. Copyright © 2016 SERAM. Publicado por Elsevier España, S.L.U. All rights reserved.
Grady, Ian; Vasquez, Tony; Tawfik, Sara; Grady, Sean
2017-03-01
To evaluate the cost-efficacy of vacuum-assisted ultrasound-guided breast biopsy instruments compared to ultrasound-guided 14-gauge spring-loaded core-needle biopsy. The American Society of Breast Surgeons' Mastery of Breast Surgery Registry was reviewed. Biopsy findings, any rebiopsy, and the instrument used were abstracted for 31,451 ultrasound-guided biopsy procedures performed between 2001 and July 2014. Rates of cancer diagnosis and rebiopsy were calculated for each instrument. A linear mathematical model was developed to calculate total cost per cancer diagnosis, including procedural costs and the costs of any additional surgical rebiopsy procedures. Mean cost per cancer diagnosis with confidence limits was then determined for 14-gauge spring-loaded core-needle biopsy and 14 different vacuum-assisted instruments. For 14-gauge spring-loaded core-needle biopsy, mean cost per cancer diagnosis was $4346 (4327-$4366). For the vacuum-assisted instruments, mean cost per cancer diagnosis ranged from a low of $3742 ($3732-$3752) to a high of $4779 ($4750-$4809). Vacuum-assisted instruments overall were more cost-effective than core with a mean cost per cancer diagnosis of $4052 ($4038-$4067) (p < 0.05). Tethered vacuum-assisted instruments performed best with a mean cost per cancer diagnosis of $3978 ($3964-$3991) (p < 0.05). Nontethered devices had a mean cost per cancer diagnosis of $4369 ($4350-$4388), a result no better than core (p < 0.05). Ultrasound-guided vacuum-assisted breast biopsy had a lower mean cost per cancer diagnosis than 14-gauge spring-loaded core-needle biopsy. This advantage was only seen in tethered vacuum-assisted instruments. Within device families, larger instruments tended to outperform smaller instruments.
Emergent Embolization of Arterial Bleeding after Vacuum-Assisted Breast Biopsy
DOE Office of Scientific and Technical Information (OSTI.GOV)
Fischman, Aaron M., E-mail: aaron.fischman@mountsinai.org; Epelboym, Yan, E-mail: yan.epelboym@mssm.edu; Siegelbaum, Robert H., E-mail: rhsiegelbaum@gmail.com
2012-02-15
Vacuum-assisted core breast biopsy has become important in evaluating patients with suspicious breast lesions. It has proven to be a relatively safe procedure that in rare cases can result in vascular complications. These are the first reported cases of transcatheter embolization of uncontrolled breast hemorrhage after vacuum-assisted breast biopsy. With increased use of biopsy and larger-gauge devices, breast imaging groups may consider embolotherapy as a safe alternative for treatment of hemorrhage in a select group of patients.
Yen, Peggy; Dumas, Sandra; Albert, Arianne; Gordon, Paula
2018-02-01
The placement of localization clips following percutaneous biopsy is a standard practice for a variety of situations. Subsequent clip displacement creates challenges for imaging surveillance and surgical planning, and may cause confusion amongst radiologists and between surgeons and radiologists. Many causes have been attributed for this phenomenon including the commonly accepted "accordion effect." Herein, we investigate the performance of a low cost surgical clip system against 4 commercially available clips. We retrospectively reviewed 2112 patients who underwent stereotactic vacuum-assisted core biopsy followed by clip placement between January 2013 and June 2016. The primary performance parameter compared was displacement >10 mm following vacuum-assisted stereotactic core biopsy. Within the group of clips that had displaced, the magnitude of displacement was compared. There was a significant difference in displacement among the clip types (P < .0001) with significant pairwise comparisons between pediatric surgical clips and SecureMark (38% vs 28%; P = .001) and SenoMark (38% vs 27%; P = .0001) in the proportion displaced. The surgical clips showed a significant magnitude of displacement of approximately 25% greater average distance displaced. As a whole, the commercial clips performed better than the surgical clip after stereotactic vacuum-assisted core biopsy suggesting the surrounding outer component acts to anchor the central clip and minimizes clip displacement. The same should apply to tomosynthesis-guided biopsy. Crown Copyright © 2017. Published by Elsevier Inc. All rights reserved.
Krammer, Julia; Dutschke, Anja; Kaiser, Clemens G; Schnitzer, Andreas; Gerhardt, Axel; Radosa, Julia C; Brade, Joachim; Schoenberg, Stefan O; Wasser, Klaus
2016-01-01
To evaluate whether tumor localization and method of preoperative biopsy affect sentinel lymph node (SLN) detection after periareolar nuclide injection in breast cancer patients. 767 breast cancer patients were retrospectively included. For lymphscintigraphy periareolar nuclide injection was performed and the SLN was located by gamma camera. Patient and tumor characteristics were correlated to the success rate of SLN mapping. SLN marking failed in 9/61 (14.7%) patients with prior vacuum-assisted biopsy and 80/706 (11.3%) patients with prior core needle biopsy. Individually evaluated, biopsy method (p = 0.4) and tumor localization (p = 0.9) did not significantly affect the SLN detection rate. Patients with a vacuum-assisted biopsy of a tumor in the upper outer quadrant had a higher odds ratio of failing in SLN mapping (OR 3.8, p = 0.09) compared to core needle biopsy in the same localization (OR 0.9, p = 0.5). Tumor localization and preoperative biopsy method do not significantly impact SLN mapping with periareolar nuclide injection. However, the failure risk tends to rise if vacuum-assisted biopsy of a tumor in the upper outer quadrant is performed.
Fast MRI-guided vacuum-assisted breast biopsy: initial experience.
Liberman, Laura; Morris, Elizabeth A; Dershaw, D David; Thornton, Cynthia M; Van Zee, Kimberly J; Tan, Lee K
2003-11-01
The purpose of this study was to evaluate a new method for performing MRI-guided vacuum-assisted breast biopsy in a study of lesions that had subsequent surgical excision. SUBJECTS AND METHODS. Twenty women scheduled for MRI-guided needle localization and surgical biopsy were prospectively entered in the study. MRI-guided biopsy was performed with a vacuum-assisted probe, followed by placement of a localizing clip, and then needle localization for surgical excision. Vacuum-assisted biopsy and surgical histology were correlated. Vacuum-assisted biopsy was successfully performed in 19 (95%) of the 20 women. The median size of 27 MRI-detected lesions that had biopsy was 1.0 cm (range, 0.4-6.4 cm). Cancer was present in eight (30%) of 27 lesions and in six (32%) of 19 women; among these eight cancers, five were infiltrating and three were ductal carcinoma in situ (DCIS). Among these 27 lesions, histology was benign at vacuum-assisted biopsy and at surgery in 19 (70%), cancer at vacuum-assisted biopsy in six (22%), atypical ductal hyperplasia at vacuum-assisted biopsy and DCIS at surgery in one (4%), and benign at vacuum-assisted biopsy with surgery showing microscopic DCIS that was occult at MRI in one (4%). The median time to perform vacuum-assisted biopsy of a single lesion was 35 min (mean, 35 min; range, 24-48 min). Placement of a localizing clip, attempted in 26 lesions, was successful in 25 (96%) of 26, and the clip was retrieved on specimen radiography in 22 (96%) of 23. One complication occurred: a hematoma that resolved with compression. MRI-guided vacuum-assisted biopsy is a fast, safe, and accurate alternative to surgical biopsy for breast lesions detected on MRI.
McCroskey, Zulfia; Sneige, Nour; Herman, Carolyn R; Miller, Ross A; Venta, Luz A; Ro, Jae Y; Schwartz, Mary R; Ayala, Alberto G
2018-02-21
The aim of this study was to analyze the clinicopathological features of patients with flat epithelial atypia, diagnosed in directional vacuum-assisted biopsy targeting microcalcifications, to identify upgrade rate to in situ ductal or invasive breast carcinoma, and determine factors predicting carcinoma in the subsequent excision. We retrospectively evaluated the histological, clinical, and mammographic features of 69 cases from 65 women, with directional vacuum-assisted biopsy-diagnosed flat epithelial atypia with or without atypical ductal hyperplasia or atypical lobular hyperplasia, which underwent subsequent surgical excision. The extent and percentage of microcalcifications sampled by directional vacuum-assisted biopsy were evaluated by mammography. All biopsy and surgical excision slides were reviewed. The age of the women ranged from 40 to 85 years (mean 57 years). All patients presented with mammographically detected microcalcifications only, except in one case that had associated architectural distortion. Extent of calcifications ranged from <1 cm (n = 47), 1-3 cm (n = 15) to > 3 cm (n = 6), and no measurement (n = 1). A mean of 11 cores (range 6-25) was obtained from each lesion. Post-biopsy mammogram revealed >90% removal of calcifications in 81% of cases. Pure flat epithelial atypia represented nearly two-thirds of directional vacuum-assisted biopsy specimens (n = 43, 62%), while flat epithelial atypia coexisted with atypical ductal hyperplasia (18 cases, 26%), or atypical lobular hyperplasia (8 cases, 12%). Upon excision, none of the cases were upgraded to in situ ductal or invasive breast cancer. In one case, however, an incidental, tubular carcinoma (4 mm) was found away from biopsy site. Excluding this case, the upgrade rate was 0%. Our study adds to the growing evidence that diagnosis of flat epithelial atypia on directional vacuum-assisted biopsy for microcalcifications as the only imaging finding is not associated with a significant upgrade to carcinoma on excision, and therefore, excision may not be necessary. Additionally, excision may not be necessary for flat epithelial atypia with atypical ductal hyperplasia limited to ≤2 terminal duct-lobular units, if at least 90% of calcifications have been removed on biopsy.
Brennan, Sandra B; Corben, Adriana; Liberman, Laura; Dershaw, D David; Brogi, Edi; Van Zee, Kimberly J; Morris, Elizabeth
2012-10-01
The objective of our study was to determine the frequency of cancer at surgery in breast lesions yielding papilloma at MRI-guided 9-gauge vacuum-assisted biopsy (VAB) and to determine whether any features are associated with cancer upgrade. For this study, 1487 MRI-guided vacuum-assisted biopsies performed from January 2004 to March 2011 were reviewed. Lesions yielding papilloma were identified and classified as papilloma with or without atypia. Surgical findings were reviewed to determine the cancer rate. Statistical analysis was performed and 95% CIs were calculated. Papilloma was identified in 75 of the 1487 MRI-guided vacuum-assisted biopsies (5%). These 75 papillomas occurred in 73 women with a median age of 49 years (age range, 27-70 years). Of the 75 papillomas, 25 (33%) had atypia and 50 (67%) did not on core needle biopsy. Subsequent surgery of 67 of the 75 papillomas (89%) yielded ductal carcinoma in situ (DCIS) in four (6%; 95% CI, 2-15%). Surgery yielded DCIS in two of 23 papillomas with atypia (9%; 95% CI, 1-28%) at MRI-guided VAB and in two of 44 papillomas without atypia (5%; 95% CI, 0.4-16%) at MRI-guided VAB; these cancer rates did not differ significantly (p=0.6). Postmenopausal status (p=0.04) and histologic size of less than 0.2 cm (p=0.04) had a significant association with the cancer upgrade rate. Papilloma with or without atypia was found in 5% of patients who underwent MRI-guided VAB during the study period. Surgery revealed cancer in 6%. DCIS was found at surgery in 9% of lesions yielding papilloma with atypia versus 5% of lesions yielding papilloma without atypia. For lesions yielding papilloma with or without atypia at MRI-guided VAB, surgical excision is warranted.
Graesslin, O; Antoine, M; Chopier, J; Seror, J Y; Flahault, A; Callard, P; Daraï, E; Uzan, S
2010-02-01
Large-core needle biopsy of the breast (LCNB) and vacuum-assisted breast biopsy (VABB) are widely used as alternatives to open surgical biopsy (OSB) for initial diagnosis of mammographic abnormalities. Between 18% and 80% of cases in which such specimens show atypical lobular hyperplasia (ALH) or atypical ductal hyperplasia (ADH) are found to be malignant at surgery. From 1999 to 2005, 68 women with mammographic abnormalities were sampled by stereotactic VABB and presented atypical epithelial hyperplasia. Immunohistochemical staining with anti-cytokeratin 5/6 and anti-E-cadherin antibodies was performed. All women underwent a lumpectomy. Clinical, radiological or histological factors predictive of the risk of finding malignancy at surgery were sought. VABB initially showed 28 cases of ADH, 32 cases of ALH, one case of flat epithelial atypia, five cases of mixed atypia, and two cases of Lobular Carcinoma In Situ (LCIS). After slide review with immunohistochemical staining, two cases of ADH were reclassified as simple hyperplasia and two cases of ALH were reclassified as mixed atypia. Seven lesions (10.3%) that appeared to be benign on VABB were found to be malignant on OSB (Ductal Carcinoma In Situ (DCIS) in six cases and invasive ductal carcinoma in one case). ADH was the only predictive factor of malignancy on OSB (p=0.04 versus ALH). ADH diagnosed by vacuum-assisted breast biopsy frequently corresponds to cancer on open surgical biopsy. Surgical excision of all breast lesions containing atypical hyperplasia on percutaneous biopsy can be recommended. Copyright (c) 2009 Elsevier Ltd. All rights reserved.
Heywang-Köbrunner, Sylvia H; Sinnatamby, Ruchi; Lebeau, Annette; Lebrecht, Antje; Britton, Peter D; Schreer, Ingrid
2009-11-01
Quality assurance of MR-guided vacuum-assisted breast biopsy (VAB). A consensus was achieved based on the existing literature and experience of an interdisciplinary group comprising European specialists in breast imaging and VAB. Full imaging work-up must be completed according to existing standards before an indication for MR-guided VAB is established. The procedure should be reserved for lesions demonstrable by MRI alone. Acquisition of >24 cores (11-Gauge) should be routinely attempted, with the intention of sufficiently removing small lesions for accurate diagnosis. Following biopsy the patient should be re-imaged to demonstrate the biopsy site and its proximity to the lesion and hence the likely accuracy of the sampling. All patients should be discussed in a regular interdisciplinary conference and a documented consensus reached regarding patient management. Regular audit and review of all MR-guided VAB results and subsequent follow-up are recommended. This consensus includes protocols for the indication, performance parameters, interdisciplinary interpretation therapeutic recommendation, documentation and follow-up of MR-guided VAB. It does not replace official recommendations for percutaneous biopsy.
Luparia, A; Durando, M; Campanino, P; Regini, E; Lucarelli, D; Talenti, A; Mattone, G; Mariscotti, G; Sapino, A; Gandini, G
2011-04-01
The authors sought to evaluate the diagnostic accuracy and cost-effectiveness of vacuum-assisted core biopsy (VACB) in comparison with diagnostic surgical excision for characterisation of nonpalpable breast lesions classified as Breast Imaging Reporting and Data System (BI-RADS) categories R3 and R4. From January 2004 to December 2008, we conducted 602 stereotactic, 11-gauge, VACB procedures on 243 nonpalpable breast lesions categorised as BI-RADS R3, 346 categorised as BI-RADS R4 and 13 categorised as BI-RADS R5. We calculated the diagnostic accuracy and cost savings of VACB by subtracting the cost of the stereotactic biopsy from that of the diagnostic surgical procedure. A total of 56% of the lesions were benign and required no further assessment. Lesions of uncertain malignant potential (B3) (23.6%) were debated at multidisciplinary meetings, and diagnostic surgical biopsy was recommended for 83.1% of them. All malignant lesions (B4 and B5) underwent surgical excision. VACB had a sensitivity of 94.9%, specificity of 98.3% and diagnostic accuracy of 97.7%. The cost savings per VACB procedure were 464.00 euro; by obviating 335 surgical biopsies, the overall cost savings was 155,440.00 euro over 5 years. VACB proved to have high diagnostic accuracy for characterising abnormalities at low to intermediate risk of malignancy and obviated surgical excision in about half of the cases, allowing for considerable cost savings.
Ultrasound-guided cable-free 13-gauge vacuum-assisted biopsy of non-mass breast lesions
Seo, Jiwoon; Jang, Mijung; Yun, Bo La; Lee, Soo Hyun; Kim, Eun-Kyu; Kang, Eunyoung; Park, So Yeon; Moon, Woo Kyung; Choi, Hye Young; Kim, Bohyoung
2017-01-01
Purpose To compare the outcomes of ultrasound-guided core biopsy for non-mass breast lesions by the novel 13-gauge cable-free vacuum-assisted biopsy (VAB) and by the conventional 14-gauge semi-automated core needle biopsy (CCNB). Materials and methods Our institutional review board approved this prospective study, and all patients provided written informed consent. Among 1840 ultrasound-guided percutaneous biopsies performed from August 2013 to December 2014, 145 non-mass breast lesions with suspicious microcalcifications on mammography or corresponding magnetic resonance imaging finding were subjected to 13-gauge VAB or 14-gauge CCNB. We evaluated the technical success rates, average specimen numbers, and tissue sampling time. We also compared the results of percutaneous biopsy and final surgical pathologic diagnosis to analyze the rates of diagnostic upgrade or downgrade. Results Ultrasound-guided VAB successfully targeted and sampled all lesions, whereas CCNB failed to demonstrate calcification in four (10.3%) breast lesions with microcalcification on specimen mammography. The mean sampling time were 238.6 and 170.6 seconds for VAB and CCNB, respectively. No major complications were observed with either method. Ductal carcinoma in situ (DCIS) and atypical ductal hyperplasia (ADH) lesions were more frequently upgraded after CCNB (8/23 and 3/5, respectively) than after VAB (2/26 and 0/4, respectively P = 0.028). Conclusion Non-mass breast lesions were successfully and accurately biopsied using cable-free VAB. The underestimation rate of ultrasound-detected non-mass lesion was significantly lower with VAB than with CCNB. Trial registration CRiS KCT0002267. PMID:28628656
Hao, Shuang; Liu, Zhe-Bin; Ling, Hong; Chen, Jia-Jian; Shen, Ju-Ping; Yang, Wen-Tao; Shao, Zhi-Min
2015-01-01
Diagnostic patterns in breast cancer have greatly changed over the past few decades, and core needle biopsy (CNB) has become a reliable procedure for detecting breast cancer without invasive surgery. To estimate the changing diagnostic patterns of breast cancer in urban Shanghai, 11,947 women with breast lesions detected by preoperative needle biopsy between January 1995 and December 2012 were selected from the Shanghai Cancer Data base, which integrates information from approximately 50% of breast cancer patients in Shanghai. The CNB procedure uses an automated prone unit, biopsy gun, and 14-gauge needles under freehand or ultrasound guidance and was performed by experienced radiologists and surgeons specializing in needle biopsies. Diagnosis and classification for each patient were independently evaluated by pathologists. Over the indicated 8-year period, biopsy type consisted of 11,947 ultrasound-guided core needle biopsies (UCNBs), 2,015 ultrasound-guided vacuum-assisted biopsies (UVABs), and 654 stereotactic X-ray-guided vacuum-assisted biopsies (XVABs). For all the 11,947 women included in this study, image-guided needle biopsy was the initial diagnostic procedure. Approximately 81.0% of biopsied samples were histopathologically determined to be malignant lesions, 5.5% were determined to be high-risk lesions, and 13.5% were determined to be benign lesions. The number of patients choosing UCNB increased at the greatest rate, and UCNB has become a standard procedure for histodiagnosis because it is inexpensive, convenient, and accurate. The overall false-negative rate of CNB was 1.7%, and the specific false-negative rates for UCNB, UVAB, and XVAB, were 1.7%, 0%, and 0%, respectively. This study suggests that the use of preoperative needle biopsy as the initial breast cancer diagnostic procedure is acceptable in urban Shanghai. Preoperative needle biopsy is now a standard procedure in the Shanghai Cancer Center because it may reduce the number of surgeries needed to treat breast cancer. PMID:26491359
Huang, Xu Chen; Hu, Xu Hua; Wang, Xiao Ran; Zhou, Chao Xi; Wang, Fei Fei; Yang, Shan; Wang, Gui Ying
2018-03-16
Core needle biopsy (CNB) and vacuum-assisted biopsy (VAB) are both popularly used breast percutaneous biopsies. Both of them have become reliable alternatives to open surgical biopsy (OSB) for breast microcalcification (BM). It is controversial that which biopsy method is more accurate and safer for BM. Hence, we conducted this meta-analysis to compare the diagnostic performance between CNB and VAB for BM, aiming to find out the better method. Articles according with including and excluding criteria were collected from the databases, PubMed, Embase, and the Cochrane Library. Preset outcomes were abstracted and pooled to find out the potential advantages in CNB or VAB. Seven studies were identified and entered final meta-analysis from initially found 138 studies. The rate of ductal carcinoma in situ (DCIS) underestimation was significantly lower in VAB than CNB group [risk ratio (RR) = 1.83, 95% confidence interval (CI) 1.40 to 2.40, p < 0.001]. The microcalcification retrieval rate was significantly higher in VAB than CNB group (RR = 0.89, 95% CI 0.81 to 0.98, p = 0.02), while CNB owned a significantly lower complication rate than VAB (RR = 0.18, 95% CI 0.03 to 0.93, p = 0.04). The atypical ductal hyperplasia (ADH) underestimation rates were not compared for the limited number of studies reporting this outcome. Compared with CNB, VAB shows better diagnostic performance in DCIS underestimation rate and microcalcification retrieval rate. However, CNB shows a significantly lower complication rate. More studies are needed to verify these findings.
Fotou, Maria; Oikonomou, Vassiliki; Zagouri, Flora; Sergentanis, Theodoros N; Nonni, Afroditi; Athanassiadou, Pauline; Drouveli, Theodora; Atsouris, Efstratios; Kotzia, Evagelia; Zografos, George C
2007-04-03
To evaluate imprint cytology in the context of specimens with microcalcifications derived from Vacuum-Assisted Breast Biopsy (VABB). A total of 93 women with microcalcifications BI-RADS 3 and 4 underwent VABB and imprint samples were examined. VABB was performed on Fischer's table using 11-gauge Mammotome vacuum probes. A mammogram of the cores after the procedure confirmed the excision of microcalcifications. For the application of imprint cytology, the cores with microcalcifications confirmed by mammogram were gently rolled against glass microscope slides and thus imprint smears were made. For rapid preliminary diagnosis Diff-Quick stain, modified Papanicolaou stain and May Grunwald Giemsa were used. Afterwards, the core was dipped into a CytoRich Red Collection fluid for a few seconds in order to obtain samples with the use of the specimen wash. After the completion of cytological procedures, the core was prepared for routine histological study. The pathologist was blind to the preliminary cytological results. The cytological and pathological diagnoses were comparatively evaluated. According to the pathological examination, 73 lesions were benign, 15 lesions were carcinomas (12 ductal carcinomas in situ, 3 invasive ductal carcinomas), and 5 lesions were precursor: 3 cases of atypical ductal hyperplasia (ADH) and 2 cases of lobular neoplasia (LN). The observed sensitivity and specificity of the cytological imprints for cancer were 100% (one-sided, 97.5% CI: 78.2%-100%). Only one case of ADH could be detected by imprint cytology. Neither of the two LN cases was detected by the imprints. The imprints were uninformative in 11 out of 93 cases (11.8%). There was no uninformative case among women with malignancy. Imprint cytology provides a rapid, accurate preliminary diagnosis in a few minutes. This method might contribute to the diagnosis of early breast cancer and possibly attenuates patients' anxiety.
Maxwell, Anthony J; Morris, Julie; Lim, Yit Y; Harake, MD Janick; Whiteside, Sigrid
2016-01-01
Objective: To compare the accuracy of 11-G vacuum-assisted biopsy (VAB) with 14-G core needle biopsy (CNB) to diagnose mammographic microcalcification (MM) and effect on surgical outcomes. Methods: Following ethical approval, VAB and CNB (control) were compared in a randomized prospective study for first-line diagnosis of MM and subsequent surgical outcomes in two breast-screening units. Participants gave written informed consent. Exclusions included comorbidity precluding surgery, prior ipsilateral breast cancer and lesions >40 mm requiring mastectomy as first surgical procedure. The final pathological diagnosis was compared with the initial biopsy result. Quality-of-life (QOL) questionnaires were administered at baseline, 2, 6 and 12 months. 110 participants were required to show a 25% improvement in diagnosis with VAB compared with CNB (90% power). Results: Eligibility was assessed for 787 cases; 129 females recalled from the National Health Service breast screening programme were randomized. Diagnostic accuracy of VAB was 86% and that of CNB was 84%. Using VAB, 2/14 (14.3%) cases upgraded from ductal carcinoma in situ to invasion at surgery and 3/19 (15.8%) using CNB. Following VAB 7/16 (44%) cases required repeat surgery vs 7/24 (29%) after CNB. Both groups recorded significant worsening of functional QOL measures and increased breast pain at follow-up. Conclusion: VAB and CNB were equally accurate at diagnosing MM, and no significant differences in surgical outcomes were observed. Advances in knowledge: The first randomized controlled study of VAB for diagnosis of microcalcification using digital mammography showed no difference in diagnostic accuracy of VAB and CNB, or in the proportion of participants needing repeat non-operative biopsy or second therapeutic operation to treat malignancy. PMID:26654214
Baez, E; Huber, A; Vetter, M; Hackelöer, B-J
2003-03-01
The aim of this study was to evaluate the use of three-dimensional (3D) ultrasonography in the complete excision of benign breast tumors using ultrasound-guided vacuum-assisted core-needle biopsy (Mammotome). A protocol for the management of benign breast tumors is proposed. Twenty consecutive patients with sonographically benign breast lesions underwent 3D ultrasound-guided mammotome biopsy under local anesthesia. The indication for surgical biopsy was a solid lesion with benign characteristics on both two-dimensional (2D) and 3D ultrasound imaging, increasing in size over time or causing pain or irritation. Preoperatively, the size of the lesion was assessed using 2D and 3D volumetry. During vacuum biopsy the needle was visualized sonographically in all three dimensions, including the coronal plane. Excisional biopsy was considered complete when no residual tumor tissue could be seen sonographically. Ultrasonographic follow-up examinations were performed on the following day and 3-6 months later to assess residual tissue and scarring. All lesions were histologically benign. Follow-up examinations revealed complete excision of all lesions of < 1.5 mL in volume as assessed by 3D volumetry. 3D ultrasonographic volume assessment was more accurate than 2D using the ellipsoid formula or assessment of the maximum diameter for the prediction of complete excision of the tumor. No bleeding or infections occurred postoperatively and no scarring was seen ultrasonographically on follow-up examinations. Ultrasound-guided vacuum-assisted biopsy allows complete excision of benign breast lesions that are =1.5 mL in volume (calculated by 3D volumetry), and thus avoids open surgery and postoperative scarring. Under local anesthesia it is a safe procedure with optimal compliance. 3D ultrasound offers the advantage of better preoperative demonstration of the lesions' margins, resulting in better assessment of volumetry, improved intraoperative needle location and perioperative identification of residual tumor tissue. 3D sonographically guided biopsy should be integrated into breast cancer screening programs as a safe therapeutic option for breast lesions presumed to be benign. Copyright 2003 ISUOG. Published by John Wiley & Sons, Ltd.
Jain, Ashali; Khalid, Maria; Qureshi, Muhammad M; Georgian-Smith, Dianne; Kaplan, Jonah A; Buch, Karen; Grinstaff, Mark W; Hirsch, Ariel E; Hines, Neely L; Anderson, Stephan W; Gallagher, Katherine M; Bates, David D B; Bloch, B Nicolas
2017-11-01
To evaluate breast biopsy marker migration in stereotactic core needle biopsy procedures and identify contributing factors. This retrospective study analyzed 268 stereotactic biopsy markers placed in 263 consecutive patients undergoing stereotactic biopsies using 9G vacuum-assisted devices from August 2010-July 2013. Mammograms were reviewed and factors contributing to marker migration were evaluated. Basic descriptive statistics were calculated and comparisons were performed based on radiographically-confirmed marker migration. Of the 268 placed stereotactic biopsy markers, 35 (13.1%) migrated ≥1 cm from their biopsy cavity. Range: 1-6 cm; mean (± SD): 2.35 ± 1.22 cm. Of the 35 migrated biopsy markers, 9 (25.7%) migrated ≥3.5 cm. Patient age, biopsy pathology, number of cores, and left versus right breast were not associated with migration status (P> 0.10). Global fatty breast density (P= 0.025) and biopsy in the inner region of breast (P = 0.031) were associated with marker migration. Superior biopsy approach (P= 0.025), locally heterogeneous breast density, and t-shaped biopsy markers (P= 0.035) were significant for no marker migration. Multiple factors were found to influence marker migration. An overall migration rate of 13% supports endeavors of research groups actively developing new biopsy marker designs for improved resistance to migration. • Breast biopsy marker migration is documented in 13% of 268 procedures. • Marker migration is affected by physical, biological, and pathological factors. • Breast density, marker shape, needle approach etc. affect migration. • Study demonstrates marker migration prevalence; marker design improvements are needed.
Initial Experience with a Wireless Ultrasound-Guided Vacuum-Assisted Breast Biopsy Device
Choi, E-Ryung; Han, Boo-Kyung; Ko, Eun Sook; Ko, Eun Young; Choi, Ji Soo; Cho, Eun Yoon; Nam, Seok Jin
2015-01-01
Objective To determine the imaging characteristic of frequent target lesions of wireless ultrasound (US)-guided, vacuum-assisted breast biopsy (Wi-UVAB) and to evaluate diagnostic yield, accuracy and complication of the device in indeterminate breast lesions. Materials and Methods From March 2013 to October 2014, 114 women (age range, 29–76 years; mean age, 50.0 years) underwent Wi-UVAB using a 13-gauge needle (Mammotome Elite®; Devicor Medical Products, Cincinnati, OH, USA). In 103 lesions of 96 women with surgical (n = 81) or follow-up (n = 22) data, complications, biopsy procedure, imaging findings of biopsy targets and histologic results were reviewed. Results Mean number of biopsy cores was 10 (range 4–25). Nine patients developed moderate bleeding. All lesions were suspicious on US, and included non-mass lesions (67.0%) and mass lesions (33.0%). Visible calcifications on US were evident in 57.3% of the target lesions. Most of the lesions (93.2%) were nonpalpable. Sixty-six (64.1%) were malignant [ductal carcinoma in situ (DCIS) rate, 61%] and 12 were high-risk lesions (11.7%). Histologic underestimation was identified in 11 of 40 (27.5%). DCIS cases and in 3 of 9 (33.3%) high-risk lesions necessitating surgery. There was no false-negative case. Conclusion Wi-UVAB is very handy and advantageous for US-unapparent non-mass lesions to diagnose DCIS, especially for calcification cases. Histologic underestimation is unavoidable; still, Wi-UVAB is safe and accurate to diagnose a malignancy. PMID:26630136
Esen, Gül; Tutar, Burçin; Uras, Cihan; Calay, Zerrin; İnce, Ümit; Tutar, Onur
2016-01-01
PURPOSE We aimed to present our biopsy method and retrospectively evaluate the results, upgrade rate, and follow-up findings of stereotactic vacuum-assisted breast biopsy (VABB) procedures performed in our clinic. METHODS Two hundred thirty-four patients with mammographically detected nonpalpable breast lesions underwent VABB using a 9 gauge biopsy probe and prone biopsy table. A total of 195 patients (median age 53 years, range 32–80 years) with 198 microcalcification-only lesions with a follow-up of at least one year were included in the study. The location of the lesion relative to the needle was determined from the postfire images, and unlike the conventional technique, tissue retrieval was predominantly performed from that location, followed by a complete 360° rotation, if needed. RESULTS The median core number was 8.5. Biopsy results revealed 135 benign, 24 atypical, and 39 malignant lesions. The total upgrade rate at surgery was 7.7% (6.1% for ductal carcinomas in situ and 10.5% for atypical lesions). Patients with benign lesions were followed up for a median period of 27.5 months, with no interval change. At the follow-up, scar formation was seen in 23 patients (17%); three of the scars were remarkable for resembling a malignancy. CONCLUSION Our biposy method is fast and practical, and it is easily tolerated by patients without compromising accuracy. Patients with a diagnosis of atypia still need to undergo a diagnostic surgical procedure and those with a malignancy need to undergo curative surgery, even if the lesion is totally excised at biopsy. VABB may leave a scar in the breast tissue, which may resemble a malignancy, albeit rarely. PMID:27306660
Preibsch, Heike; Baur, Astrid; Wietek, Beate M; Krämer, Bernhard; Staebler, Annette; Claussen, Claus D; Siegmann-Luz, Katja C
2015-09-01
Published national and international guidelines and consensus meetings on the use of vacuum-assisted biopsy (VAB) give different recommendations regarding the required numbers of tissue specimens depending on needle size and imaging method. To evaluate the weights of specimens obtained with different VAB needles to facilitate the translation of the required number of specimens between different breast biopsy systems and needle sizes, respectively. Five different VAB systems and seven different needle sizes were used: Mammotome® (11-gauge (G), 8-G), Vacora® (10-G), ATEC Sapphire™ (9-G), 8-G Mammotome® Revolve™, and EnCor Enspire® (10-G, 7-G). We took 24 (11-G) or 20 (7-10-G) tissue cores from a turkey breast phantom. The mean weight of a single tissue core was calculated for each needle size. A matrix, which allows the translation of the required number of tissue cores for different needle sizes, was generated. Results were compared to the true cumulative tissue weights of consecutively harvested tissue cores. The mean tissue weights obtained with the 11-G / 10-G Vacora® / 10-G Enspire® / 9-G / 8-G Original / 8-G Revolve™ / 7-G needles were 0.084 g / 0.142 g / 0.221 g / 0.121 g / 0.192 g / 0.334 g / 0.363 g, respectively. The calculated required numbers of VAB tissue cores for each needle size build the matrix. For example, the minimum calculated number of required cores according to the current German S3 guideline is 20 / 12 / 8 / 14 / 9 / 5 / 5 for needles of 11-G / 10-G Vacora® / 10-G Enspire® / 9-G / 8-G Original / 8-G Revolve™ / 7-G size. These numbers agree with the true cumulative tissue weights. The presented matrix facilitates the translation of the required number of VAB specimens between different needle sizes and thereby eases the implementation of current guidelines and consensus recommendations into clinical practice. © The Foundation Acta Radiologica 2014.
The Management Strategy of Benign Solitary Intraductal Papilloma on Breast Core Biopsy.
Ko, Dayoung; Kang, Eunyoung; Park, So Yeon; Kim, Sun Mi; Jang, Mijung; Yun, Bo La; Chae, Sumin; Jang, Yerang; Kim, Hye Jin; Kim, Sung-Won; Kim, Eun-Kyu
2017-08-01
Intraductal papilloma (IDP) is well-known as one of the common benign breast lesions requiring excision. However, treatment of IDP without atypia is controversial. The aim of our study was to determine the proper management of solitary IDP by core needle biopsy (CNB). We retrospectively reviewed patients with solitary IDP confirmed by CNB from March 2003 to March 2015. We collected data about final pathology after excision, as well as clinical, histologic, and radiologic findings at initial diagnosis. The final pathology was categorized as benign or malignant. We evaluated the rate of upgrade to malignancy and factors associated with malignancy. We identified 405 patients who presented benign solitary IDP by CNB. The mean age was 46.1 years (range, 15-86 years). In total, 135 patients underwent surgical excision, and 211 underwent vacuum-assisted excision. Of 346 patients, malignant lesions were found in 8 patients (2.3%): 7 underwent surgical excision, and 1 underwent vacuum-assisted excision. Only the size of IDP was significantly associated with cancer upgrade (P = .003). Our study shows that overall malignancy upgrade rate of benign solitary IDP after excision is very low (2.3%). Even when the size of IDP was less than 1 cm, the upgrade rate to cancer was only 0.9%. Therefore, for patients with small solitary IDP, we recommend close follow-up with ultrasound instead of excision. Copyright © 2017 Elsevier Inc. All rights reserved.
Noske, Aurelia; Pahl, Stefan; Fallenberg, Eva; Richter-Ehrenstein, Christiane; Buckendahl, Ann-Christin; Weichert, Wilko; Schneider, Achim; Dietel, Manfred; Denkert, Carsten
2010-04-01
The biological behavior and the optimal management of benign breast lesions with uncertain malignant potential, the so-called B3 lesions, found in breast needle core biopsies is still under debate. We addressed this study to compare histologic findings in B3 needle core biopsies with final excision specimens to determine associated rates of malignancy. Consecutive needle core biopsies were performed in a 3-year period (January 1, 2006-December 31, 2008). Biopsies were image-guided (31 by ultrasound, 85 stereotactic vacuum-assisted, 6 unknown) for evaluation of breast abnormalities. We reviewed 122 needle core biopsies with B3 lesions of 91 symptomatic patients and 31 screen-detected women and compared the B3 histologic subtypes with the final excision histology. A total of 1845 needle core biopsies were performed and B3 lesions comprised 6.6% of all B categories. The most common histologic subtype in biopsies was flat epithelia atypia in 35.2%, followed by papillary lesions in 21% and atypical ductal hyperplasia in 20%. Reports on excision specimens were available in 66% (81 patients). Final excision histology was benign in 73 (90.2%) and malignant in 8 (9.8%) patients (2 invasive cancer, 6 ductal carcinoma in situ). Of all B3 subtypes, atypical ductal hyperplasia and flat epithelial atypia were associated with malignancy, whereas only atypical ductal hyperplasia was accompanied by invasive cancer. Of all lesions, flat epithelial atypia was most frequently found in excision specimens (18%). In our study, flat epithelial atypia and atypical ductal hyperplasia are common lesions of the B3 category in needle core biopsies of the breast. Both lesions are associated with malignancy, whereas only atypical ductal hyperplasia was related to invasive cancer. We conclude that an excision biopsy after diagnosis of flat epithelial atypia is recommended depending on clinical and radiologic findings. Copyright 2010 Elsevier Inc.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Wallace, Adam N., E-mail: wallacea@mir.wustl.edu; Pacheco, Rafael A., E-mail: pachecor@mir.wustl.edu; Tomasian, Anderanik, E-mail: tomasiana@mir.wustl.edu
2016-02-15
BackgroundA novel coaxial biopsy system powered by a handheld drill has recently been introduced for percutaneous bone biopsy. This technical note describes our initial experience performing fluoroscopy-guided vertebral body biopsies with this system, compares the yield of drill-assisted biopsy specimens with those obtained using a manual technique, and assesses the histologic adequacy of specimens obtained with drill assistance.MethodsMedical records of all single-level, fluoroscopy-guided vertebral body biopsies were reviewed. Procedural complications were documented according to the Society of Interventional Radiology classification. The total length of bone core obtained from drill-assisted biopsies was compared with that of matched manual biopsies. Pathology reportsmore » were reviewed to determine the histologic adequacy of specimens obtained with drill assistance.ResultsTwenty eight drill-assisted percutaneous vertebral body biopsies met study inclusion criteria. No acute complications were reported. Of the 86 % (24/28) of patients with clinical follow-up, no delayed complications were reported (median follow-up, 28 weeks; range 5–115 weeks). The median total length of bone core obtained from drill-assisted biopsies was 28 mm (range 8–120 mm). This was longer than that obtained from manual biopsies (median, 20 mm; range 5–45 mm; P = 0.03). Crush artifact was present in 11 % (3/28) of drill-assisted biopsy specimens, which in one case (3.6 %; 1/28) precluded definitive diagnosis.ConclusionsA drill-assisted, coaxial biopsy system can be used to safely obtain vertebral body core specimens under fluoroscopic guidance. The higher bone core yield obtained with drill assistance may be offset by the presence of crush artifact.« less
Dialani, Vandana; Venkataraman, Shambhavi; Frieling, Gretchen; Schnitt, Stuart J; Mehta, Tejas S
2014-01-01
To determine whether flat epithelial atypia (FEA) found in isolation on large core vacuum-assisted biopsy (CNB) requires surgical excision. After Institutional Review Board approval, pathology reports of all patients who underwent CNB from January 1, 2005 to December 31, 2010 were reviewed. All patients with reports of isolated FEA without other atypia or in situ or invasive carcinoma were identified. Patient age, history, target on imaging, biopsy modality, and residual target post CNB noted. Histology of CNB's (blinded to surgical outcome) and subsequent surgical excisions were reviewed by a dedicated breast pathologist. Only cases with confirmed isolated FEA on review were used for data analysis. Of 2,556 CNB's performed over 6 years, 37 (1.4%) had isolated FEA confirmed on review, comprising our study population. Thirty (81%) had biopsy for calcifications on mammography and 7 (19%) for mass or non-mass like enhancement on magnetic resonance imaging. There were no US guided CNBs that met our inclusion criteria. 29 (78.4%) underwent surgical excision, 6 (16.2%) had imaging follow-up, and 2 (5.4%) were lost to follow-up. Of the 29 with surgery, 2 (6.9%) had "upgrade" to low-grade in situ carcinoma (1 ductal and 1 pleomorphic lobular), 5 (17.2%) had "change in diagnosis" to other atypia (ADH/ALH), 15 (51.7%) had additional FEA and 7 (24.2%) had benign tissue without atypia. Both "upgraded" cases had residual microcalcifications on imaging following CNB. There were no upgrades to invasive cancers. In our study, none of 29 with isolated FEA on CNB had invasive cancer on surgical excision. If there are residual microcalcifications or residual lesion after a CNB that shows isolated FEA, excision is warranted, due to the possibility of other atypia (ADH/ALH [17.2%] or DCIS [5.4%]). If there are no residual microcalcifications following CNB, imaging follow-up as an alternative to surgery may be a reasonable option. © 2014 Wiley Periodicals, Inc.
Sim, Y T; Litherland, J; Lindsay, E; Hendry, P; Brauer, K; Dobson, H; Cordiner, C; Gagliardi, T; Smart, L
2015-05-01
To identify factors affecting upgrade rates from B5a (non-invasive) preoperative core biopsies to invasive disease at surgery and ways to improve screening performance. This was a retrospective analysis of 1252 cases of B5a biopsies across all six Scottish Breast Screening Programmes (BSPs), ranging between 2004 and 2012. Final surgical histopathology was correlated with radiological and biopsy factors. Data were analysed using basic Microsoft Excel and standard Chi-squared test used for evaluating statistical significance. B5a upgrade rates for the units ranged from 19.2% to 29.2%, with an average of 23.6%. Mean sizes of invasive tumours were small (3-11 mm). The upgrade rate was significantly higher for cases where the main mammographic abnormality was mass, distortion, or asymmetry, compared with micro-calcification alone (33.2% versus 21.7%, p = 0.0004). The upgrade rate was significantly lower with the use of large-volume vacuum-assisted biopsy (VAB) devices than 14 G core needles (19.9% versus 26%, p = 0.013); in stereotactic than ultrasound-guided biopsies (21.2% versus 36.1%, p < 0.001). Heterogeneity of data from different centres limited evaluation of other potential factors. Upgrade rates are lower for cases with micro-calcification as the sole mammographic feature with the use of VAB devices. Nevertheless, there is variation in practice across Scottish BSPs, including first-line biopsy technique and/or device; and it is of interest that a few centres maintain low upgrade rates despite not using VAB routinely for biopsy of micro-calcification. Copyright © 2015 The Royal College of Radiologists. Published by Elsevier Ltd. All rights reserved.
Han, Song-Hee; Kim, Milim; Chung, Yul Ri; Yun, Bo La; Jang, Mijung; Kim, Sun Mi; Kang, Eunyoung; Kim, Eun-Kyu; Park, So Yeon
2018-03-01
The management of benign intraductal papilloma (IDP) without atypia diagnosed on core needle biopsy (CNB) remains controversial. This study was performed to evaluate the rate of upgrading to malignancy or high-risk lesions after excision and to identify factors associated with upgrading using a large series of benign IDP cases without atypia. We included patients who were diagnosed as having benign IDP without atypia on CNB and underwent surgical or vacuum-assisted excision between 2010 and 2015. We analyzed the clinical, radiologic, and histopathologic features of IDPs that were upgraded to malignancy or high-risk lesions after excision. A total of 511 benign IDPs without atypia diagnosed via CNB were identified, of which 398 cases were treated with excision. After reviewing these cases, four cases of high-risk lesions in adjacent tissue on CNB, two cases which were revealed as papilloma with atypia, and nine cases of malignancy in the same breast were excluded. In the remaining 383 cases, the rate of upgrading to malignancy and high-risk lesions after excision was 0.8% and 4.4%, respectively. The presence of concurrent contralateral breast cancer, the presence of symptoms, and multifocality were factors significantly associated with upgrading to malignancy on subsequent excision. Surgical excision rather than vacuum-assisted excision was significantly associated with upgrading to high-risk lesions or malignancy. The rate of upgrading to malignancy for benign IDP without atypia was very low, suggesting that close clinical and radiologic observation may be sufficient for patients with benign IDP without atypia on CNB under proper settings.
Hahn, Soo Yeon; Shin, Jung Hee; Han, Boo-Kyung; Ko, Eun Young
2011-02-01
Management of suspicious microcalcifications in very thin breasts is problematic. To evaluate whether sonographically-guided vacuum-assisted biopsy (USVAB) with digital mammography-guided skin marking (DM) for the diagnosis of breast microcalcifications is comparable to stereotactic-guided vacuum-assisted biopsy (SVAB) in Asian women with thin breasts. Retrospective review was performed for 263 consecutive suspicious microcalcification lesions in 261 women who underwent USVAB with DM or SVAB using a prone table between January 2004 and December 2007. SVAB was performed for 190 lesions and USVAB for 73 lesions. Biopsy results were correlated with surgical pathology or followed up for at least 12 months. The diagnostic outcomes of SVAB and USVAB to diagnose microcalcifications were compared. Of 263 lesions, 104 (40%) underwent surgery and 159 (60%) were followed up. SVAB and USVAB groups showed similar final categories or the extent of microcalcifications. US visible lesions were 57 (78%) of 73 at USVAB and 14 (10%) of 140 at SVAB. Of 57 US visible lesions at USVAB, 29 (51%) were not found in initial US but were detectable with the help of DM. Specimen radiographs were negative in 2.1% of lesions at SVAB and in 4.1% at USVAB (p=0.4008). The under-estimation rate and false-negative rate were similar in SVAB and USVAB. US with DM facilitates US visibility of microcalcifications. USVAB with DM can produce acceptable biopsy results, as can SVAB, to diagnose breast microcalcifications in patients with thin breasts.
Yamamoto, Naohito; Fujimoto, Hiroshi; Nakamura, Rikiya; Arai, Manabu; Yoshii, Atsushi; Kaji, Sachiko; Itami, Makiko
2011-01-01
There is increasing demand for minimally invasive treatments for small breast cancer mainly because of the desire for better cosmetic results. Although radiofrequency ablation (RFA) is an attractive approach as a local control method for small breast cancer, the problems of histological effectiveness and safety management remain. A total of 29 patients including one patient with bilateral breast cancer were enrolled in this study. The mean tumor size of 30 breasts was 12.8 mm (range 5-19 mm). Under general anesthesia, RFA was performed with a Cool-tip RF system (Valleylab, Boulder, CO, USA) after sentinel lymph node biopsy. Postoperative evaluation with magnetic resonance imaging (MRI) and vacuum-assisted core needle biopsy was done 3-4 weeks after RFA before radiotherapy. Ablated tumors were evaluated with hematoxylin-eosin (H&E) and nicotinamide adenine dinucleotide (NADH)-diaphorase staining. If needed, adjuvant chemo and/or endocrine therapy was performed. All patients except one completed one session of RFA. The mean temperature near the center of the tumors was 89.6°C (range 78-100°C). Postoperative MRI showed the ablated zone clearly in all patients. MRI revealed no hypervascularity of the tumors in the ablated zone. Evaluation with H&E staining of the tumors showed remarkable degenerative changes in only three patients. NADH-diaphorase staining showed no viable tumor tissue in 24 patients out of 26 examined. Three patients received small diameter grade 3 skin burns, two on the outside of the thigh from the grounding pad and one on the breast skin. One patient had a breast lesion like a chronic granulomatous mastitis resulting from overreaction of the ablated zone. RFA therapy appeared relevant and applicable for patients with small breast cancer. Because small skin burns were observed as adverse events, close attention should be paid in the course of the RFA procedure.
Ouldamer, Lobna; Poisson, Elodie; Arbion, Flavie; Bonneau, Carole; Vildé, Anne; Body, Gilles; Michenet, Patrick
2018-04-14
The purposes of this study were to evaluate the outcome of women with pure flat atypical atypia (FEA) diagnosed at vacuum-assisted breast biopsy (VABB) targeting microcalcifications and to determine whether clinical, radiological and pathologic parameters are able to predict which lesions will be upgraded to malignancy. 2414 cases of consecutive VABB for microcalcifications using VA 8-, 10- or 11-Gauge stereotactically guided core biopsy performed between January 2005 and December 2011 from two french breast cancer centers were evaluated. Data of women with VABB-diagnosed pure FEA who underwent either excisional surgery or mammographic follow-up were analyzed. Cases with mass lesions or ipsilateral cancers were excluded. Two pathologists (FA,PM) reviewed the results of procedures performed. Clinical, radiological, as well as histological criteria have been studied in order to determine the correlation between these factors and carcinoma underestimation. This study included 70 cases of pure FEA. Twenty women underwent surgical excision and 50 had clinical and mammographic surveillance only. In three women FEA was upgraded to breast cancer on excision. Clinical and mammographic follow-up for a mean of 56 months ± 27 in the group without excision showed two cancers in the same breast (Intermediate grade DCIS, and invasive ductal carcinoma 84 and 48 months respectively after VABB). Three factors were significantly predictive of underestimation or occurence of cancer for pure FEA when the radiologic lesions are calcifications: age≥ 57 years, radiologic size >10 mm and number of FEA foci ≥4. Copyright © 2018. Published by Elsevier Ltd.
Han, Song-Hee; Kim, Milim; Chung, Yul Ri; Yun, Bo La; Jang, Mijung; Kim, Sun Mi; Kang, Eunyoung; Kim, Eun-Kyu
2018-01-01
Purpose The management of benign intraductal papilloma (IDP) without atypia diagnosed on core needle biopsy (CNB) remains controversial. This study was performed to evaluate the rate of upgrading to malignancy or high-risk lesions after excision and to identify factors associated with upgrading using a large series of benign IDP cases without atypia. Methods We included patients who were diagnosed as having benign IDP without atypia on CNB and underwent surgical or vacuum-assisted excision between 2010 and 2015. We analyzed the clinical, radiologic, and histopathologic features of IDPs that were upgraded to malignancy or high-risk lesions after excision. Results A total of 511 benign IDPs without atypia diagnosed via CNB were identified, of which 398 cases were treated with excision. After reviewing these cases, four cases of high-risk lesions in adjacent tissue on CNB, two cases which were revealed as papilloma with atypia, and nine cases of malignancy in the same breast were excluded. In the remaining 383 cases, the rate of upgrading to malignancy and high-risk lesions after excision was 0.8% and 4.4%, respectively. The presence of concurrent contralateral breast cancer, the presence of symptoms, and multifocality were factors significantly associated with upgrading to malignancy on subsequent excision. Surgical excision rather than vacuum-assisted excision was significantly associated with upgrading to high-risk lesions or malignancy. Conclusion The rate of upgrading to malignancy for benign IDP without atypia was very low, suggesting that close clinical and radiologic observation may be sufficient for patients with benign IDP without atypia on CNB under proper settings. PMID:29628987
Lavoué, Vincent; Fritel, Xavier; Antoine, Martine; Beltjens, Françoise; Bendifallah, Sofiane; Boisserie-Lacroix, Martine; Boulanger, Loic; Canlorbe, Geoffroy; Catteau-Jonard, Sophie; Chabbert-Buffet, Nathalie; Chamming's, Foucauld; Chéreau, Elisabeth; Chopier, Jocelyne; Coutant, Charles; Demetz, Julie; Guilhen, Nicolas; Fauvet, Raffaele; Kerdraon, Olivier; Laas, Enora; Legendre, Guillaume; Mathelin, Carole; Nadeau, Cédric; Naggara, Isabelle Thomassin; Ngô, Charlotte; Ouldamer, Lobna; Rafii, Arash; Roedlich, Marie-Noelle; Seror, Jérémy; Séror, Jean-Yves; Touboul, Cyril; Uzan, Catherine; Daraï, Emile
2016-05-01
Screening with breast ultrasound in combination with mammography is needed to investigate a clinical breast mass (Grade B), colored single-pore breast nipple discharge (Grade C), or mastitis (Grade C). The BI-RADS system is recommended for describing and classifying abnormal breast imaging findings. For a breast abscess, a percutaneous biopsy is recommended in the case of a mass or persistent symptoms (Grade C). For mastalgia, when breast imaging is normal, no MRI or breast biopsy is recommended (Grade C). Percutaneous biopsy is recommended for a BI-RADS category 4-5 mass (Grade B). For persistent erythematous nipple or atypical eczema lesions, a nipple biopsy is recommended (Grade C). For distortion and asymmetry, a vacuum core-needle biopsy is recommended due to the risk of underestimation by simple core-needle biopsy (Grade C). For BI-RADS category 4-5 microcalcifications without any ultrasound signal, a minimum 11-G vacuum core-needle biopsy is recommended (Grade B). In the absence of microcalcifications on radiography cores additional samples are recommended (Grade B). For atypical ductal hyperplasia, atypical lobular hyperplasia, lobular carcinoma in situ, flat epithelial atypia, radial scar and mucocele with atypia, surgical excision is commonly recommended (Grade C). Expectant management is feasible after multidisciplinary consensus. For these lesions, when excision margins are not clear, no new excision is recommended except for LCIS characterized as pleomorphic or with necrosis (Grade C). For grade 1 phyllodes tumor, surgical resection with clear margins is recommended. For grade 2 phyllodes tumor, 10mm margins are recommended (Grade C). For papillary breast lesions without atypia, complete disappearance of the radiological signal is recommended (Grade C). For papillary breast lesions with atypia, complete surgical excision is recommended (Grade C). Copyright © 2016 Elsevier Ireland Ltd. All rights reserved.
Papathemelis, Thomas; Heim, Stefanie; Lux, Michael P.; Erhardt, Ines; Scharl, Anton; Scharl, Sophia
2017-01-01
Introduction We studied the extent to which an ultrasound-guided vacuum-assisted biopsy device (“hand-held Mammotome”) could be used not only as a valuable tool for investigation of suspicious breast lesions, but also therapeutically for the complete removal of breast fibroadenomas. Materials and Methods 132 aspiration biopsies showing fibroadenoma on histology were collected retrospectively. We ascertained whether there were residual findings on breast ultrasound at a median follow-up of approx. 9 months following biopsy. A questionnaire was used to determine the complication rate, patient satisfaction and acceptance of the procedure. Results In this study complete fibroadenomectomy was achieved at aspiration biopsy in 76 % of cases (n = 132). Compared to fibroadenomas larger than 2.51 cm3 (59 %), those smaller than 2.5 cm3 were completely removed more often (87.6 %; p < 0.05). The procedure is associated with very little pain during and after biopsy and minimal haematoma development, both factors supporting a high rate of acceptance among patients. Conclusion Ultrasound-guided vacuum-assisted biopsy is safe and associated with very few complications. Its additional therapeutic potential is dependant on the size of the benign lesion as measured at initial ultrasound. PMID:28331240
Bianchi, Simonetta; Bendinelli, Benedetta; Castellano, Isabella; Piubello, Quirino; Renne, Giuseppe; Cattani, Maria Grazia; Di Stefano, Domenica; Carrillo, Giovanna; Laurino, Licia; Bersiga, Alessandra; Giardina, Carmela; Dante, Stefania; Di Loreto, Carla; Quero, Carmela; Antonacci, Concetta Maria; Palli, Domenico
2012-10-01
Flat epithelial atypia (FEA) may represent the earliest precursor of low-grade breast cancer and often coexists with more advanced atypical proliferative breast lesions such as atypical ductal hyperplasia (ADH) and lobular intraepithelial neoplasia (LIN). The present study aims to investigate the association between morphological parameters of FEA and presence of malignancy at surgical excision (SE) and the clinical significance of the association of FEA with ADH and/or LIN. This study included 589 cases of stereotactic 11-gauge vacuum-assisted needle core biopsy (VANCB), reporting a diagnosis of FEA, ADH or LIN with subsequent SE from 14 pathology departments in Italy. Available slides were reviewed, with 114 (19.4 %) showing a malignant outcome at SE. Among the 190 cases of pure FEA, no statistically significant association emerged between clinical-pathological parameters of FEA and risk of malignancy. Logistic regression analyses showed an increased risk of malignancy according to the extension of ADH among the 275 cases of FEA associated with ADH (p = 0.004) and among the 34 cases of FEA associated with ADH and LIN (p = 0.02). In the whole series, a statistically significant increased malignancy risk emerged according to mammographic R1-R3/R4-R5 categories (OR = 1.56; p = 0.04), extension (OR = 1.24; p = 0.04) and grade (OR = 1.94; p = 0.004) of cytological atypia of FEA. The presence of ADH was associated with an increased malignancy risk (OR = 2.85; p < 0.0001). Our data confirm the frequent association of FEA with ADH and/or LIN. A diagnosis of pure FEA on VANCB carries a 9.5 % risk of concurrent malignancy and thus warrants follow-up excision because none of the clinical-pathological parameters predicts which cases will present carcinoma on SE.
Flat epithelial atypia and atypical ductal hyperplasia: carcinoma underestimation rate.
Ingegnoli, Anna; d'Aloia, Cecilia; Frattaruolo, Antonia; Pallavera, Lara; Martella, Eugenia; Crisi, Girolamo; Zompatori, Maurizio
2010-01-01
This study was carried out to determine the underestimation rate of carcinoma upon surgical biopsy after a diagnosis of flat epithelial atypia and atypical ductal hyperplasia and 11-gauge vacuum-assisted breast biopsy. A retrospective review was conducted of 476 vacuum-assisted breast biopsy performed from May 2005 to January 2007 and a total of 70 cases of atypia were identified. Fifty cases (71%) were categorized as pure atypical ductal hyperplasia, 18 (26%) as pure flat epithelial atypia and two (3%) as concomitant flat epithelial atypia and atypical ductal hyperplasia. Each group were compared with the subsequent open surgical specimens. Surgical biopsy was performed in 44 patients with atypical ductal hyperplasia, 15 patients with flat epithelial atypia, and two patients with flat epithelial atypia and atypical ductal hyperplasia. Five cases of atypical ductal hyperplasia were upgraded to ductal carcinoma in situ, three cases of flat epithelial atypia yielded one ductal carcinoma in situ and two cases of invasive ductal carcinoma, and one case of flat epithelial atypia/atypical ductal hyperplasia had invasive ductal carcinoma. The overall rate of malignancy was 16% for atypical ductal hyperplasia (including flat epithelial atypia/atypical ductal hyperplasia patients) and 20% for flat epithelial atypia. The presence of flat epithelial atypia and atypical ductal hyperplasia at biopsy requires careful consideration, and surgical excision should be suggested.
Male breast cancer is rare: an initial presentation may be as an abscess.
Ventham, N T; Hussien, M I
2010-08-06
Breast cancer in men is rare. Breast cancer presenting initially as an abscess has been described only a handful of times in the literature. We present the first described case of invasive adenocarcinoma presenting as an abscess in a man. An 80-year-old diabetic man presented with symptoms typical of a breast abscess. The abscess failed to respond to percutaneous therapy and excision of breast abscess was performed. Histology revealed an invasive carcinoma. He went on to have a mastectomy. Histology should be obtained from breast abscesses not resolving within 2 months of initial percutaneous therapy. Histology could be obtained by ultrasound-guided fine-needle aspiration (FNA), core or vacuum assisted biopsy, or by formal incision and drainage.
Male breast cancer is rare: an initial presentation may be as an abscess
Ventham, N T; Hussien, M I
2010-01-01
Breast cancer in men is rare. Breast cancer presenting initially as an abscess has been described only a handful of times in the literature. We present the first described case of invasive adenocarcinoma presenting as an abscess in a man. An 80-year-old diabetic man presented with symptoms typical of a breast abscess. The abscess failed to respond to percutaneous therapy and excision of breast abscess was performed. Histology revealed an invasive carcinoma. He went on to have a mastectomy. Histology should be obtained from breast abscesses not resolving within 2 months of initial percutaneous therapy. Histology could be obtained by ultrasound-guided fine-needle aspiration (FNA), core or vacuum assisted biopsy, or by formal incision and drainage. PMID:22767683
Li, Jie; Dershaw, D David; Lee, Carol H; Kaplan, Jennifer; Morris, Elizabeth A
2009-09-01
Follow-up MRI can be useful to confirm a benign diagnosis after MRI-guided breast biopsy. This retrospective study was undertaken to evaluate appropriate timing and imaging interpretation for the initial follow-up MRI when a benign, concordant histology is obtained using MRI-guided breast biopsy. Retrospective review was performed of 177 lesions visualized only by MRI in 172 women who underwent 9-gauge, vacuum-assisted core biopsy and marker placement with imaging-concordant benign histology. All underwent follow-up MRI within 12 months. Timing of the follow-up study, change in size, results of second biopsy if performed, and distance of localizing marker to the lesion on the follow-up study were recorded. At initial follow-up, 155 lesions were decreased or gone, 14 lesions were stable, and eight were enlarged. Seventeen (9.6%, 17/177) lesions underwent a second biopsy, including six enlarging, 10 stable, and one decreasing. Of these, four were malignant. Enlargement was seen in two carcinomas at 6 and 12 months. Two carcinomas, one stable at 2 months and another stable at 3 and 11 months, were rebiopsied because of suspicion of a missed lesion in the former and worrisome mammographic and sonographic changes in the latter. The distance of the marker from the lesion on follow-up did not correlate with biopsy accuracy. Follow-up MRI did not detect missed cancers because of lesion enlargement before 6 months after biopsy; two of four missed cancers were stable. The localizing marker can deploy away from the target despite successful sampling.
Polymer film-nanoparticle composites as new multimodality, non-migrating breast biopsy markers.
Kaplan, Jonah A; Grinstaff, Mark W; Bloch, B Nicolas
2016-03-01
To develop a breast biopsy marker that resists fast and slow migration and has permanent visibility under commonly used imaging modalities. A polymer-nanoparticle composite film was prepared by embedding superparamagnetic iron oxide nanoparticles and a superelastic Nitinol wire within a flexible polyethylene matrix. MRI, mammography, and ultrasound were used to visualize the marker in agar, ex vivo chicken breast, bovine liver, brisket, and biopsy training phantoms. Fast migration caused by the "accordion effect" was quantified after simulated stereotactic, vacuum-assisted core biopsy/marker placement, and centrifugation was used to simulate accelerated long-term (i.e., slow) migration in ex vivo bovine tissue phantoms. Clear marker visualization under MRI, mammography, and ultrasound was observed. After deployment, the marker partially unfolds to give a geometrically constrained structure preventing fast and slow migration. The marker can be deployed through an 11G introducer without fast migration occurring, and shows substantially less slow migration than conventional markers. The polymer-nanoparticle composite biopsy marker is clearly visible on all clinical imaging modalities and does not show substantial migration, which ensures multimodal assessment of the correct spatial information of the biopsy site, allowing for more accurate diagnosis and treatment planning and improved breast cancer patient care. Polymer-nanoparticle composite biopsy markers are visualized using ultrasound, MRI, and mammography. Embedded iron oxide nanoparticles provide tuneable contrast for MRI visualization. Permanent ultrasound visibility is achieved with a non-biodegradable polymer having a distinct ultrasound signal. Flexible polymer-based biopsy markers undergo shape change upon deployment to minimize migration. Non-migrating multimodal markers will help improve accuracy of pre/post-treatment planning studies.
THERAPEUTIC STRATEGY FOR GRANULOMATOUS LOBULAR MASTITIS: A CLINICOPATHOLOGICAL STUDY OF 12 PATIENTS
AKAHANE, KAZUHISA; TSUNODA, NOBUYUKI; KATO, MASAMICHI; NODA, SUMIYO; SHIMOYAMA, YOSHIE; ISHIGAKI, SATOKO; SATAKE, HIROKO; NAKAMURA, SHIGEO; NAGINO, MASATO
2013-01-01
ABSTRACT Granulomatous lobular mastitis (GLM) is a rare inflammatory pseudotumor. No therapeutic modality for this disease has been established because of its rarity. The purpose of this study is to evaluate the treatment strategies of GLM. Twelve women who met the histological criteria for GLM were retrospectively studied. The clinical data and the presentation, histopathology, and management of the disease were analyzed by reviewing the patients’ medical records. The diagnosis of GLM was confirmed histologically by core needle biopsy in 9 cases, by vacuum-assisted biopsy in 2 cases, and by excisional biopsy in 1 case. Ten patients received corticosteroid treatment and another two patients were treated with local excision or incision and drainage. The median initial dosage of corticosteroid (Prednisolone) was 30 mg/day (range: 15–60 mg/day), and the dosages were tapered according to improvement. The median duration of corticosteroid treatment was 5 months (range: 1–12 months). The median follow-up period was 22 months (range: 6–104 months), and no patient treated with corticosteroid demonstrated recurrence. However, patients treated with excision or incision and drainage had recurrences. These results suggest that steroid treatment may be the first choice in treatment strategies for GLM. PMID:24640175
Therapeutic strategy for granulomatous lobular mastitis: a clinicopathological study of 12 patients.
Akahane, Kazuhisa; Tsunoda, Nobuyuki; Kato, Masamichi; Noda, Sumiyo; Shimoyama, Yoshie; Ishigakis, Satoko; Satake, Hiroko; Nakamura, Shigeo; Nagino, Masato
2013-08-01
Granulomatous lobular mastitis (GLM) is a rare inflammatory pseudotumor. No therapeutic modality for this disease has been established because of its rarity. The purpose of this study is to evaluate the treatment strategies of GLM. Twelve women who met the histological criteria for GLM were retrospectively studied. The clinical data and the presentation, histopathology, and management of the disease were analyzed by reviewing the patients' medical records. The diagnosis of GLM was confirmed histologically by core needle biopsy in 9 cases, by vacuum-assisted biopsy in 2 cases, and by excisional biopsy in 1 case. Ten patients received corticosteroid treatment and another two patients were treated with local excision or incision and drainage. The median initial dosage of corticosteroid (Prednisolone) was 30 mg/day (range: 15-60 mg/day), and the dosages were tapered according to improvement. The median duration of corticosteroid treatment was 5 months (range: 1-12 months). The median follow-up period was 22 months (range: 6-104 months), and no patient treated with corticosteroid demonstrated recurrence. However, patients treated with excision or incision and drainage had recurrences. These results suggest that steroid treatment may be the first choice in treatment strategies for GLM.
Rageth, Christoph J; O'Flynn, Elizabeth Am; Comstock, Christopher; Kurtz, Claudia; Kubik, Rahel; Madjar, Helmut; Lepori, Domenico; Kampmann, Gert; Mundinger, Alexander; Baege, Astrid; Decker, Thomas; Hosch, Stefanie; Tausch, Christoph; Delaloye, Jean-François; Morris, Elisabeth; Varga, Zsuzsanna
2016-09-01
The purpose of this study is to obtain a consensus for the therapy of B3 lesions. The first International Consensus Conference on lesions of uncertain malignant potential in the breast (B3 lesions) including atypical ductal hyperplasia (ADH), flat epithelial atypia (FEA), classical lobular neoplasia (LN), papillary lesions (PL), benign phyllodes tumors (PT), and radial scars (RS) took place in January 2016 in Zurich, Switzerland organized by the International Breast Ultrasound School and the Swiss Minimally Invasive Breast Biopsy group-a subgroup of the Swiss Society of Senology. Consensus recommendations for the management and follow-up surveillance of these B3 lesions were developed and areas of research priorities were identified. The consensus recommendation for FEA, LN, PL, and RS diagnosed on core needle biopsy or vacuum-assisted biopsy (VAB) is to therapeutically excise the lesion seen on imaging by VAB and no longer by open surgery, with follow-up surveillance imaging for 5 years. The consensus recommendation for ADH and PT is, with some exceptions, therapeutic first-line open surgical excision. Minimally invasive management of selected B3 lesions with therapeutic VAB is acceptable as an alternative to first-line surgical excision.
Bianchi, Simonetta; Bendinelli, Benedetta; Saladino, Valeria; Vezzosi, Vania; Brancato, Beniamino; Nori, Jacopo; Palli, Domenico
2015-07-01
One-hundred-fourteen consecutive cases of breast ultrasound-guided 14-gauge needle core biopsy (14G NCB) performed from January 2001 to June 2013 and diagnosed as non-malignant papillary lesion (PL)-B3, were reviewed and compared with definitive histological diagnosis on surgical excision (SE) to evaluate the diagnostic accuracy of ultrasound-guided 14G NCB. PL with epithelial atypia on 14G NCB were associated to malignancy on definitive histological diagnosis on SE in 22 (7 DCIS and 15 invasive carcinomas) of 46 cases with an underestimation rate of 47.8 %, while 9 (4 DCIS and 5 invasive carcinomas) cases out of 68 cases of PL without epithelial atypia were upgraded to carcinoma with an underestimation rate of 13.2 %. In cases of PL with epithelial atypia on ultrasound-guided 14G NCB, SE appears mandatory due to the high risk of associated malignancy. The diagnosis of PL without epithelial atypia on ultrasound-guided 14G NCB does not exclude malignancy at subsequent SE, consequently further assessment (by surgical or vacuum-assisted excision) is recommended to avoid the risk of delaying a diagnosis of malignancy, although this tends to be lower (1 in 8 patients).
Nayak, Anupma; Carkaci, Selin; Gilcrease, Michael Z.; Liu, Ping; Middleton, Lavinia P.; Bassett, Roland L.; Zhang, Jinxia; Zhang, Hong; Coyne, Robin L.; Bevers, Therese B.; Sneige, Nour; Huo, Lei
2015-01-01
The management of benign papilloma (BP) without atypia identified on breast core needle biopsy (CNB) is controversial. We describe the clinicopathologic features of 80 patients with such lesions in our institution, with an upgrade rate to malignancy of 3.8%. A multidisciplinary approach to select patients for surgical excision is recommended. Background The management of benign papilloma (BP) without atypia identified on breast core needle biopsy (CNB) is controversial. In this study, we determined the upgrade rate to malignancy for BPs without atypia diagnosed on CNB and whether there are factors associated with upgrade. Methods Through our pathology database search, we studied 80 BPs without atypia identified on CNB from 80 patients from 1997 to 2010, including 30 lesions that had undergone excision and 50 lesions that had undergone ≥ 2 years of radiologic follow-up. Associations between surgery or upgrade to malignancy and clinical, radiologic, and pathologic features were analyzed. Results Mass lesions, lesions sampled by ultrasound-guided CNB, and palpable lesions were associated with surgical excision. All 3 upgraded cases were mass lesions sampled by ultrasound-guided CNB. None of the lesions with radiologic follow-up only were upgraded to malignancy. The overall upgrade rate was 3.8%. None of the clinical, radiologic, or histologic features were predictive of upgrade. Conclusion Because the majority of patients can be safely managed with radiologic surveillance, a selective approach for surgical excision is recommended. Our proposed criteria for excision include pathologic/radiologic discordance or sampling by ultrasound-guided CNB without vacuum assistance when the patient is symptomatic or lesion size is ≥ 1.5 cm. PMID:24119786
Tomasino, Rosa M; Morello, Vincenza; Gullo, Arianna; Pompei, Giancarlo; Agnese, Valentina; Russo, Antonio; Rinaldi, Gaetana
2009-11-01
It is essential to reach a better understanding of "flat epithelial atypia/columnar cell lesions" (FEA/CCLs) in breast core biopsies. Our aim was to explore their biological nature, in order to predict the likelihood of an upgrade to carcinoma. "Cytological grading" has been specially focused, in view of its possible utility in the choice of management. One hundred thirty of a total of 900 cases core needle (CN)/vacuum-assisted biopsies (VABs), with diagnoses of "hyperplasia" and "atypia" were retrospectively re-evaluated. Pathological findings of further excision biopsies (FEBs) performed in 40/75 patients with follow-up were compared with the previous diagnoses. In all cases, both Ki-67 and c-kit immunoreactivities were explored and compared with both normal breast tissues and subsequently documented cancers, with special reference to the hyperplastic FEA/CCLs, with "mild" atypia (FEA/CCHAm). Sixteen cases were re-diagnosed as "usual ductal hyperplasia" (UDH), 60 as "columnar cell hyperplasia" (CCH), and 54 as FEA/CCHA, 30 of which FEA/CCHAm and 24 FEA/CCHAh (with high atypia). Significantly, the Ki-67 index proved to be on the increase and c-kit expression on the decrease in FEA/CCHA lesions, mainly in the FEA/CCHAh group and in the subsequently observed cancers, compared with either benign tissues or the FEA/CCH cases. It was also significant that most of the carcinomas were found in FEBs within the FEA/CCHAh group. In this study cytological grading, together with Ki-67 and c-kit indices, proved to be helpful in FEA/CCLs evaluation. With regard to FEA/CCHAm lesions, an adequate surveillance appears to be a more appropriate management tool than FEB, as a result of their biological nature and behavior.
Green, R S; Mathew, S
2001-01-01
Between 1995 and 1996, 96 consecutive patients with nonpalpable breast lesions detected by abnormal mammogram underwent core needle biopsies under stereotactic guidance at Johns Hopkins Bayview Medical Center. The cytologic diagnoses rendered on touch imprints and the histopathologic diagnoses made on the core needle biopsies were retrospectively reviewed to ascertain the accuracy and the validity of this procedure. These imprints were made of the cores as on-site evaluation in order to assist the radiologist. Separate diagnoses were rendered on the imprints and the cores. Follow-up excisional/open biopsies were then correlated to determine the usefulness of making touch imprints from the core needle biopsies toward the overall management of a patient with an abnormal mammogram. The core needle biopsies were obtained with a 14-gauge needle and biopsy gun. The cytologic diagnoses rendered on touch imprints and histopathologic diagnoses on core needle biopsies were compared and the concordance rate was determined. The subsequent surgical follow-up was analyzed and correlated with the imprint cytology and the core needle biopsy interpretation to ascertain the pathologic outcome. A total of 100 cases were reviewed: 4 patients had two lesions biopsied. Eighty-four cases showed complete cytohistologic correlation, that is, a high concordance rate. These 84 cases were divided into four categories: malignant (24), atypical (2), benign (55), and unsatisfactory (3). Of these concordant cases, there were 34 subsequent excisional biopsies and all except one confirmed the core needle biopsy diagnosis. The exception had a benign touch imprint and core but the excisional biopsy showed multifocal ductal carcinoma in situ. Of the 100 cases, 16 were nonconcordant (the cytologic diagnosis fell into a different category from the histologic diagnosis). Seven of these nonconcordant cases resulted in excisional biopsies and all but one showed the core diagnosis to be correct. The only exception was a case with atypical cytology and a benign core biopsy with the follow-up excision showing atypia. The rest of the nonconcordant cases with atypical imprints and benign cores had no follow-up surgery, showing that the clinicians are inclined to depend on the core biopsy diagnosis. While our study demonstrates the accuracy and concordance of cytologic touch imprints, the surgical follow-up data reveal that there does not appear to be any additive value to rendering a separate diagnosis on touch imprints of core needle biopsies.
Kuba, Sayaka; Yamaguchi, Junzo; Ohtani, Hiroshi; Shimokawa, Isao; Maeda, Shigeto; Kanematsu, Takashi
2009-01-01
We report the cases of three patients with granulomatous lobular mastitis (GLM), who were treated successfully with low-dose steroid therapy. Furthermore, the findings of our review of 271 patients reported in the literature suggest that steroid therapy is the treatment of choice for GLM.
Impact of stereotactic 11-g vacuum-assisted breast biopsy on cost of diagnosis in Austria.
Gruber, R; Walter, E; Helbich, T H
2011-01-01
To determine the frequency with which stereotactic 11-g vacuum-assisted breast biopsy (11-g SVAB) obviates an open surgical biopsy (OSB), to compare the costs of these two biopsy methods, and to estimate the potential cost savings attributable to 11-g SVAB in the diagnosis of suspicious breast lesions in patients in Austria. We retrospectively reviewed 318 consecutive breast lesions of BI-RADS categories IV and V (microcalcifications n=166; masses n=152) on which 11-g SVAB and OSB were performed. Cost savings were calculated using nationally allowed flat rates and patient charges. Costs were measured from a hospital and a socioeconomic perspective. Common clinical scenarios and sensitivity analyses assessed the extent of achievable cost savings. 11-g SVAB obviated the need for an OSB in 93 (29%) of 318 women. Overall cost savings per 11-g SVAB over OSB were € 242 per case from a hospital perspective, and € 422 per case from a socioeconomic perspective. The use of 11-g SVAB decreased the cost of diagnosis by 7% from a hospital perspective, and by 10% from a socioeconomic perspective. In Austria, annual national savings of over 5 million Euro could be realized with the use of 11-g SVAB for the diagnosis of suspicious breast lesions. Although savings per case are modest, the national health care system realizes significant cost reduction as women benefit from a faster and less invasive approach to diagnosis. Copyright © 2009 Elsevier Ireland Ltd. All rights reserved.
Gruber, R; Bernt, R; Helbich, T H
2008-02-01
To analyze the cost-effectiveness of percutaneous image-guided CNBB (stereotactic-/ultrasound-guided; large/vacuum-assisted) of non-palpable breast lesions vs. OSB and to compare and discuss the results reported in the literature with results for German-speaking countries. A key word search in three databases, limited to the period from 1/1994 to 12/2006 was performed. Only original papers were selected. No published articles for German-speaking countries were identified; therefore a comprehensive data collection was made. On the basis of 377 abstracts, nine studies were evaluated for final assessment. The data of German-speaking countries were compared with results reported in the literature. This study demonstrates that CNBB compared to OSB leads to reduction in cost ranging from 51-96 %. The cost reduction depends on biopsy modality and lesion type and is subject to national fluctuations. CNBB can replace a surgical procedure in 71-85 % of cases. Use of CNBB as an alternative to OSB has the potential to substantially reduce healthcare costs. The data are based almost exclusively on the North American literature. A potential cost reduction in the Netherlands and Switzerland confirms these findings. Future work must include cost evaluation studies for German-speaking countries since this is an issue with important national economic ramifications.
El Khoury, M; Mesurolle, B; Omeroglu, A; Aldis, A; Kao, E
2013-05-01
Determine values of pathological analysis of the canister content during a vacuum-assisted breast biopsy (VABB). Approval was obtained from the ethical committee. Prospective radiological and pathological analyses of the canister content collected during 231 VABBs performed on 231 patients were carried out. χ(2) test was used to determine predictors on canister pathology. The canister pathology was reported separately in 212 cases. It showed only blood in 78/212 (37%) cases and benign (including high-risk lesions) and malignant results in, respectively, 113/212 (53%) and 21/212 (10%) cases. Respective specimen analysis was benign, including high-risk lesions in 162/212 cases (76%) and malignant in 50/212 (24%) cases. Microcalcifications were documented on canister X-ray in 70/231 (30%) cases. There was significant association between the canister and the specimen pathology (p<0.0001). In none of the cases was microcalcifications seen exclusively in the canister content or pathological upgrading found in the canister content compared with the specimen. Small tissue fragments and microcalcifications may be lost in the canister during a VABB. Nevertheless, our results did not show any significant value for systematic analysis of the canister content. There is no added diagnostic value to retrieval and analysis of tissue lost in the canister during a VABB.
A novel semi-robotized device for high-precision 18F-FDG-guided breast cancer biopsy.
Hellingman, D; Teixeira, S C; Donswijk, M L; Rijkhorst, E J; Moliner, L; Alamo, J; Loo, C E; Valdés Olmos, R A; Stokkel, M P M
To assess the 3D geometric sampling accuracy of a new PET-guided system for breast cancer biopsy (BCB) from areas within the tumour with high 18 F-FDG uptake. In the context of the European Union project MammoCare, a prototype semi-robotic stereotactic prototype BCB-device was incorporated into a dedicated high resolution PET-detector for breast imaging. The system consists of 2 stacked rings, each containing 12 plane detectors, forming a dodecagon with a 186mm aperture for 3D reconstruction (1mm 3 voxel). A vacuum-assisted biopsy needle attached to a robot-controlled arm was used. To test the accuracy of needle placement, the needle tip was labelled with 18 F-FDG and positioned at 78 target coordinates distributed over a 35mm×24mm×28mm volume within the PET-detector field-of-view. At each position images were acquired from which the needle positioning accuracy was calculated. Additionally, phantom-based biopsy proofs, as well as MammoCare images of 5 breast cancer patients, were evaluated for the 3D automated locating of 18 F-FDG uptake areas within the tumour. Needle positioning tests revealed an average accuracy of 0.5mm (range 0-1mm), 0.6mm (range 0-2mm), and 0.4mm (range 0-2mm) for the x/y/z-axes, respectively. Furthermore, the MammoCare system was able to visualize and locate small (<10mm) regions with high 18 F-FDG uptake within the tumour suitable for PET-guided biopsy after being located by the 3D automated application. Accuracy testing demonstrated high-precision of this semi-automatic 3D PET-guided system for breast cancer core needle biopsy. Its clinical feasibility evaluation in breast cancer patients scheduled for neo-adjuvant chemotherapy will follow. Copyright © 2016 Elsevier España, S.L.U. y SEMNIM. All rights reserved.
Labler, Ludwig; Rancan, Mario; Mica, Ladislav; Härter, Luc; Mihic-Probst, Daniela; Keel, Marius
2009-03-01
Clinical observations are suggesting accelerated granulation tissue formation in traumatic wounds treated with vacuum-assisted closure (VAC). Aim of this study was to determine the impact of VAC therapy versus alternative Epigard application on local inflammation and neovascularization in traumatic soft tissue wounds. Thirty-two patients with traumatic wounds requiring temporary coverage (VAC n = 16; Epigard n = 16) were included. At each change of dressing, samples of wound fluid and serum were collected (n = 80). The cytokines interleukin (IL)-6, IL-8, vascular endothelial growth factor (VEGF), and fibroblast growth factor-2 were measured by ELISA. Wound biopsies were examined histologically for inflammatory cells and degree of neovascularization present. All cytokines were found to be elevated in wound fluids during both VAC and Epigard treatment, whereas serum concentrations were negligible or not detectable. In wound fluids, significantly higher IL-8 (p < 0.001) and VEGF (p < 0.05) levels were detected during VAC therapy. Furthermore, histologic examination revealed increased neovascularization (p < 0.05) illustrated by CD31 and von Willebrand factor immunohistochemistry in wound biopsies of VAC treatment. In addition, there was an accumulation of neutrophils as well as an augmented expression of VEGF (p < 0.005) in VAC wound biopsies. This study suggests that VAC therapy of traumatic wounds leads to increased local IL-8 and VEGF concentrations, which may trigger accumulation of neutrophils and angiogenesis and thus, accelerate neovascularization.
Vacuum enhanced cutaneous biopsy instrument
Collins, Joseph
2000-01-01
A syringe-like disposable cutaneous biopsy instrument equipped with a tubular blade at its lower end, and designed so that a vacuum is created during use, said vacuum serving to retain undeformed a plug of tissue cut from a patient's skin.
Khoumais, Nuha A; Scaranelo, Anabel M; Moshonov, Hadas; Kulkarni, Supriya R; Miller, Naomi; McCready, David R; Youngson, Bruce J; Crystal, Pavel; Done, Susan J
2013-01-01
to determine the frequency of malignancy in subsequent breast excisions following core-needle biopsy (CNB) diagnosis of pure flat epithelial atypia (pFEA) and to evaluate the imaging features of the associated tumors. Retrospective review of 8,996 image-guided CNB (2002-2010) identified 115 cases of FEA not associated with other atypia. Patients with history of breast cancer or radiation therapy were excluded. One hundred four cases (women) with pFEA (mean age 51 years, range 29-77 years) were reviewed. Stereotactic CNB was performed in 79 (76%) cases and ultrasound (US)-guided CNB in 25 (24%) cases. In 99 cases 14G needles were used, and 10G vacuum-assisted devices were used in 5 cases. Ninety-four patients had subsequent excision. Ten patients declined excision, and imaging follow-up (mean of 36 months) is available. The upgrade rate of pFEA was defined as the number of patients diagnosed with invasive carcinoma (IC) or carcinoma in situ (CIS) divided by the total number of patients. 10 of 104 (9.6%) patients were diagnosed with cancer: 9 presented as calcifications (89% fine pleomorphic and amorphous) and 1 case as a mammographically occult mass. The size of calcifications was not statistically significant (P=0.358). Five cases had ductal carcinoma in situ (DCIS) and five cases had IC (ductal and lobular) presenting as amorphous and pleomorphic calcifications. The upgrade rate of pFEA in our series was 9.6%. The presence of 4.8% of invasive cancers is substantial and warrants continuing management with surgical excision in all cases.
Gleason 6 prostate cancer in one or two biopsy cores can harbor more aggressive disease.
Katz, Mark H; Shikanov, Sergey; Sun, Maxine; Abdollah, Firas; Budaeus, Lars; Gong, Edward M; Eggener, Scott E; Steinberg, Gary D; Zagaja, Gregory P; Shalhav, Arieh L; Karakiewicz, Pierre I; Zorn, Kevin C
2011-04-01
Patients with Gleason (GL) 6 prostate cancer in one or two biopsy cores can be upgraded and/or upstaged at the time of surgery, which may adversely impact long-term outcome. A novel model for prediction of adverse pathologic outcomes was developed using preoperative characteristics. Between 2003 and 2007, 1159 patients underwent robot-assisted radical prostatectomy (RARP) at our institution. GL 6 prostate cancer in one or two biopsy cores was identified in 416 (36%) patients. Logistic regression analyses were used to assess the rate of GL ≥7 and/or extraprostatic extension at RARP. Covariates consisted of age, body mass index (BMI), number of positive cores, greatest percent of cancer in a core (GPC), clinical stage, and preoperative prostate-specific antigen (PSA) level. After backward variable selection, the developed model was internally validated using the area under the curve and subjected to methods of calibration. Respectively, 278 (67%) and 138 (33%) patients had one or two positive biopsy cores. At RARP, 90 (22%) patients were upgraded to GL ≥7 and 37 (9%) had extraprostatic extension. The novel model relied on age, BMI, preoperative PSA level, and GPC for prediction of adverse pathologic outcomes and was 69% accurate. Calibration plot revealed a virtually perfect relationship between predicted and observed probabilities. In patients with GL 6 prostate cancer in one or two biopsy cores, 25% have more ominous pathology at RARP. The model provides an individual assessment of adverse outcomes at surgery. Consequently, it may be considered when counseling patients regarding their management options.
Kim, Soo-Yeon; Kim, Eun-Kyung; Lee, Hye Sun; Kim, Min Jung; Yoon, Jung Hyun; Koo, Ja Seung; Moon, Hee Jung
2016-06-01
For asymptomatic benign papillomas detected at ultrasonography-guided 14-gauge core-needle biopsy (US-CNB), the decision to perform excision versus observation has been a topic of debate. We sought to determine which subgroup of asymptomatic benign papillomas without atypia diagnosed at US-CNB can be safely managed by observation versus immediate excision. Overall, 230 asymptomatic benign papillomas in 197 women (mean age 46.6 ± 9.5 years; range 22-78), diagnosed at US-CNB using immunohistochemistry staining when needed and then managed by surgery (n = 144) or vacuum-assisted excision (VAE) with at least 12 months of follow-up after benign VAE results (n = 86) were included in this study. The upgrade rate to malignancy was calculated. Clinical and radiological variables, including age, size, Breast Image Reporting and Data System (BI-RADS) category, and imaging-pathology correlation were evaluated to find associations with malignancy using multivariate analysis. The upgrade rate to malignancy was 2.6 % (6 of 230): four were ductal carcinomas in situ and two were 1.5- and 9-mm-sized invasive ductal carcinomas without lymph node metastasis. The upgrade rates of papillomas with a BI-RADS category 3-4a and imaging-pathology concordance were 1.4 and 1.8 %, respectively. Category 4b-5 and imaging-pathology discordance were independently associated with malignancy, with upgrade rates of 13 and 50 %, respectively. Age and lesion size were not associated with malignancy. Asymptomatic benign papillomas with probable benign or low suspicious US features or imaging-pathology concordance can be followed-up as opposed to immediate excision.
Yashi, Masahiro; Nukui, Akinori; Tokura, Yuumi; Takei, Kohei; Suzuki, Issei; Sakamoto, Kazumasa; Yuki, Hideo; Kambara, Tsunehito; Betsunoh, Hironori; Abe, Hideyuki; Fukabori, Yoshitatsu; Nakazato, Yoshimasa; Kaji, Yasushi; Kamai, Takao
2017-06-23
Many urologic surgeons refer to biopsy core details for decision making in cases of localized prostate cancer (PCa) to determine whether an extended resection and/or lymph node dissection should be performed. Furthermore, recent reports emphasize the predictive value of prostate-specific antigen density (PSAD) for further risk stratification, not only for low-risk PCa, but also for intermediate- and high-risk PCa. This study focused on these parameters and compared respective predictive impact on oncologic outcomes in Japanese PCa patients. Two-hundred and fifty patients with intermediate- and high-risk PCa according to the National Comprehensive Cancer Network (NCCN) classification, that underwent robot-assisted radical prostatectomy at a single institution, and with observation periods of longer than 6 months were enrolled. None of the patients received hormonal treatments including antiandrogens, luteinizing hormone-releasing hormone analogues, or 5-alpha reductase inhibitors preoperatively. PSAD and biopsy core details, including the percentage of positive cores and the maximum percentage of cancer extent in each positive core, were analyzed in association with unfavorable pathologic results of prostatectomy specimens, and further with biochemical recurrence. The cut-off values of potential predictive factors were set through receiver-operating characteristic curve analyses. In the entire cohort, a higher PSAD, the percentage of positive cores, and maximum percentage of cancer extent in each positive core were independently associated with advanced tumor stage ≥ pT3 and an increased index tumor volume > 0.718 ml. NCCN classification showed an association with a tumor stage ≥ pT3 and a Gleason score ≥8, and the attribution of biochemical recurrence was also sustained. In each NCCN risk group, these preoperative factors showed various associations with unfavorable pathological results. In the intermediate-risk group, the percentage of positive cores showed an independent predictive value for biochemical recurrence. In the high-risk group, PSAD showed an independent predictive value. PSAD and biopsy core details have different performance characteristics for the prediction of oncologic outcomes in each NCCN risk group. Despite the need for further confirmation of the results with a larger cohort and longer observation, these factors are important as preoperative predictors in addition to the NCCN classification for a urologic surgeon to choose a surgical strategy.
Diagnostic accuracy of pre-treatment biopsy for grading cutaneous mast cell tumours in dogs.
Shaw, T; Kudnig, S T; Firestone, S M
2018-06-01
Mast cell tumours (MCTs) are common tumours of the canine skin, and are estimated to represent up to 20% of all skin tumours in dogs. Tumour grade has a major impact on the incidence of local recurrence and metastatic potential. In addition to helping the clinician with surgical planning, knowledge of the tumour grade also assists in proper prognostication and client education. For pre-treatment biopsies to be useful, there must exist a high level of correlation between the histopathological grade obtained from the pre-treatment biopsy and the actual histopathological grade from the excisional biopsy. The aim of this study was to determine concordance of tumour grade between various biopsy techniques (wedge, punch, needle core) and the "gold standard" excisional biopsy method. We found an overall concordance rate of 96% based on the Patnaik grading system, and an overall concordance rate of 92% based on the Kiupel grading system. The accuracy of the various biopsy techniques (wedge, punch and needle core) when compared with excisional biopsy was 92%, 100% and 100%, respectively, based on the Patnaik grading system, and 90%, 95% and 100%, respectively, based on the Kiupel grading system. Of the cases with discordant results, the pre-treatment biopsies tended to underestimate the grade of the tumour. Based on these results, we conclude that pre-treatment biopsies are sufficiently accurate for differentiating low-grade from high-grade MCTs, regardless of biopsy technique or tumour location. © 2017 John Wiley & Sons Ltd.
[Management of breast nipple discharge: Recommendations].
Ouldamer, L; Kellal, I; Legendre, G; Ngô, C; Chopier, J; Body, G
2015-12-01
To investigate diagnostic value of imaging procedures and management strategies of the patients with nipple discharge (ND) to establish management recommendations. Bibliographical search in French and English languages by consultation of PubMed, Cochrane and Embase databases. Although, all ND require an systematic evaluation guided by clinical data, bloody ND could be a predictor of breast cancer risk among different colors of discharge particularly in patients of more than 50 years (LE2). The mammography and breast ultrasography are the imaging procedures to realize in first intention (grade C) but they turn out useful only when they detect radiological abnormalities (LE4). Galactography has only a localizing value of possible ductal abnormalities (when standard imaging procedures is not contributive) (LE4). Thus, in the diagnostic investigation of a suspicious ND, galactography it is not recommended in standard practice (grade C). The breast Magnetic Resonance Imaging (MRI) is recommended when breast standard imaging procedures are not contributive (grade C). The ND cytology is useful only if it is positive (i.e. reveal cancer cells). There is no proof on the diagnostic performance of the cytological analysis of the ND to allow a recommendation on its realization or not. In front of a suspicious ND, when breast-imaging procedures reveals an associated radiological lesion, an adapted percutaneous biopsy is recommended by percutaneous way (grade C). Vacuum-assisted breast biopsies is a diagnostic tool but can also be therapeutic allowing to avoid surgery in case of benign lesion but current literature data do not allow recommendations on the therapeutic aspect of vacuum-assisted breast biopsy (LE4). In the absence of associated radiological signal, and in case of reproducible bloody persistent ND, a pyramidectomy is recommended (grade C). Copyright © 2015 Elsevier Masson SAS. All rights reserved.
[Benign proliferative breast disease with and without atypia].
Coutant, C; Canlorbe, G; Bendifallah, S; Beltjens, F
2015-12-01
In the last few years, diagnostics of high-risk breast lesions (atypical ductal hyperplasia [ADH], flat epithelial atypia [FEA], lobular neoplasia: atypical lobular hyperplasia [ALH], lobular carcinoma in situ [LCIS], radial scar [RS], usual ductal hyperplasia [UDH], adenosis, sclerosing adenosis [SA], papillary breast lesions, mucocele-like lesion [MLL]) have increased with the growing number of breast percutaneous biopsies. The management of these lesions is highly conditioned by the enlarged risk of breast cancer combined with either an increased probability of finding cancer after surgery, either a possible malignant transformation (in situ or invasive cancer), or an increased probability of developing cancer on the long range. An overview of the literature reports grade C recommendations concerning the management and follow-up of these lesions: in case of ADH, FEA, ALH, LCIS, RS, MLL with atypia, diagnosed on percutaneous biopsies: surgical excision is recommended; in case of a diagnostic based on vacuum-assisted core biopsy with complete disappearance of radiological signal for FEA or RS without atypia: surgical abstention is a valid alternative approved by multidisciplinary meeting. In case of ALH (incidental finding) associated with benign lesion responsible of radiological signal: abstention may be proposed; in case of UDH, adenosis, MLL without atypia, diagnosed on percutaneous biopsies: the concordance of radiology and histopathology findings must be ensured. No data is available to recommend surgery; in case of non-in sano resection for ADH, FEA, ALH, LCIS (except pleomorphic type), RS, MLL: surgery does not seem to be necessary; in case of previous ADH, ALH, LCIS: a specific follow-up is recommended in accordance with HAS's recommendations. In case of FEA and RS or MLL combined with atypia, little data are yet available to differ the management from others lesions with atypia; in case of UDH, usual sclerosing adenosis, RS without atypia, fibro cystic disease: no specific follow-up is recommended in agreement with HAS's recommendations. Copyright © 2015 Elsevier Masson SAS. All rights reserved.
Mischinger, Johannes; Kaufmann, Sascha; Russo, Giorgio I; Harland, Niklas; Rausch, Steffen; Amend, Bastian; Scharpf, Marcus; Loewe, Lorenz; Todenhoefer, Tilman; Notohamiprodjo, Mike; Nikolaou, Konstantin; Stenzl, Arnulf; Bedke, Jens; Kruck, Stephan
2018-05-01
To evaluate the performance of transperineal robot-assisted (RA) targeted (TB) and systematic (SB) prostate biopsy in primary and repeat biopsy settings. Patients underwent RA biopsy between 2014 and 2016. Before RA-TB, multiparametric magnetic resonance imaging (mpMRI) was performed. Prostate lesions were scored (Prostate Imaging, Reporting and Data System, version 2) and used for RA-TB planning. In addition, RA-SB was performed. Available, whole-gland pathology was analysed. In all, 130 patients were biopsy naive and 72 had had a previous negative transrectal ultrasonography-guided biopsy. In total, 202 patients had suspicious mpMRI lesions. Clinically significant prostate cancer was found in 85% of all prostate cancer cases (n = 123). Total and clinically significant prostate cancer detection rates for RA-TB vs RA-SB were not significantly different at 77% vs 84% and 80% vs 82%, respectively. RA-TB demonstrated a better sampling performance compared to RA-SB (26.4% vs 13.9%; P < 0.001). Transperineal RA-TB and -SB showed similar clinically significant prostate cancer detection rates in primary and repeat biopsy settings. However, RA-TB offered a 50% reduction in biopsy cores. Omitting RA-SB is associated with a significant risk of missing clinically significant prostate cancer. © 2017 The Authors BJU International © 2017 BJU International Published by John Wiley & Sons Ltd.
Tuliao, Patrick H; Koo, Kyo C; Komninos, Christos; Chang, Chien H; Choi, Young D; Chung, Byung H; Hong, Sung J; Rha, Koon H
2015-12-01
To determine the impact of prostate size on positive surgical margin (PSM) rates after robot-assisted radical prostatectomy (RARP) and the preoperative factors associated with PSM. In all, 1229 men underwent RARP by a single surgeon, from 2005 to August of 2013. Excluded were patients who had transurethral resection of the prostate, neoadjuvant therapy, clinically advanced cancer, and the first 200 performed cases (to reduce the effect of learning curve). Included were 815 patients who were then divided into three prostate size groups: <31 g (group 1), 31-45 g (group 2), >45 g (group 3). Multivariate analysis determined predictors of PSM and biochemical recurrence (BCR). Console time and blood loss increased with increasing prostate size. There were more high-grade tumours in group 1 (group 1 vs group 2 and group 3, 33.9% vs 25.1% and 25.6%, P = 0.003 and P = 0.005). PSM rates were higher in prostates of <45 g with preoperative PSA levels of >20 ng/dL, Gleason score ≥7, T3 tumour, and ≥3 positive biopsy cores. In group 1, preoperative stage T3 [odds ratio (OR) 3.94, P = 0.020] and ≥3 positive biopsy cores (OR 2.52, P = 0.043) were predictive of PSM, while a PSA level of >20 ng/dL predicted the occurrence of BCR (OR 5.34, P = 0.021). No preoperative factors predicted PSM or BCR for groups 2 and 3. A preoperative biopsy with ≥3 positive cores in men with small prostates predicts PSM after RARP. In small prostates with PSM, a PSA level of >20 ng/dL is a predictor of BCR. These factors should guide the choice of therapy and indicate the need for closer postoperative follow-up. © 2014 The Authors BJU International © 2014 BJU International Published by John Wiley & Sons Ltd.
Arakawa, H; Nakajima, Y; Kurihara, Y; Niimi, H; Ishikawa, T
1996-07-01
We retrospectively investigated the diagnostic accuracy and complication rate of transthoracic core biopsy using an automated biopsy gun and compared the findings with those of aspiration needle biopsy. Seventy-three patients underwent 74 core biopsy procedures and 50 patients underwent 52 aspiration biopsy procedures. Of these, a final diagnosis was obtained in 107 lesions with surgery or clinical course. Fifteen patients in which a final diagnosis was not obtained were excluded from the study on diagnostic accuracy. Thus, in the study of diagnostic accuracy, 63 core biopsy procedures for 62 lesions are included. Core biopsy was performed with an 18 G cutting needle using an automated biopsy gun. Aspiration biopsy was performed with a 20 G aspiration needle. Core biopsy yielded sufficient material in 57/63 procedures (90.5%). A correct diagnosis was obtained in 36 procedures (85.7%) for malignant leisons and a specific benign diagnosis was obtained in 11 procedures (52.4%). Aspiration biopsy yielded a correct diagnosis in 26 procedures (81.3%) for malignant leisons and in seven (46.7%) for benign lesions. The overall correct diagnosis were 75.8% and 71.7% with core biopsy and aspiration biopsy, respectively. Core biopsy gave a higher predictive rate than that of aspiration biopsy for both benign and malignant lessons (P < 0.02). Pneumothorax occurred in 18/74 (24.3%) patients with core biopsy and in 18/45 (40.0%) patients with aspiration biopsy. Of these, three with core biopsy and two with aspiration biopsy needed tube drainage. The other complication was haemoptysis, which occurred in six patients following core biopsy and in three after aspiration biopsy. All nine cases subsided spontaneously. There were no fatal complications. Core biopsy with a biopsy gun increase the diagnostic accuracy with a higher histologic predictive rate and no obvious additional risk of complications.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Haseler, Luke J., E-mail: l.haseler@griffith.edu.au; Sibbitt, Randy R., E-mail: THESIBB2@aol.com; Sibbitt, Wilmer L., E-mail: wsibbitt@salud.unm.edu
Purpose: Syringes are used for diagnostic fluid aspiration and fine-needle aspiration biopsy in interventional procedures. We determined the benefits, disadvantages, and patient safety implications of syringe and needle size on vacuum generation, hand force requirements, biopsy/fluid yield, and needle control during aspiration procedures. Materials and Methods: Different sizes (1, 3, 5, 10, and 20 ml) of the conventional syringe and aspirating mechanical safety syringe, the reciprocating procedure device, were studied. Twenty operators performed aspiration procedures with the following outcomes measured: (1) vacuum (torr), (2) time to vacuum (s), (3) hand force to generate vacuum (torr-cm{sup 2}), (4) operator difficulty duringmore » aspiration, (5) biopsy yield (mg), and (6) operator control of the needle tip position (mm). Results: Vacuum increased tissue biopsy yield at all needle diameters (P < 0.002). Twenty-milliliter syringes achieved a vacuum of -517 torr but required far more strength to aspirate, and resulted in significant loss of needle control (P < 0.002). The 10-ml syringe generated only 15% less vacuum (-435 torr) than the 20-ml device and required much less hand strength. The mechanical syringe generated identical vacuum at all syringe sizes with less hand force (P < 0.002) and provided significantly enhanced needle control (P < 0.002). Conclusions: To optimize patient safety and control of the needle, and to maximize fluid and tissue yield during aspiration procedures, a two-handed technique and the smallest syringe size adequate for the procedure should be used. If precise needle control or one-handed operation is required, a mechanical safety syringe should be considered.« less
Can magnetic resonance imaging obviate the need for biopsy for microcalcifications?
Chishima, Takashi
2017-01-01
Background Although microcalcifications detected with mammography (MG) are usually biopsied, biopsies cannot be performed in all cases. We sought to determine if magnetic resonance imaging (MRI) findings could indicate whether stereotactic vacuum-assisted biopsy (SVAB) is necessary. Methods Patients with mammographically detected Breast Imaging-Reporting and Data System (BI-RADS) 3, 4, and 5 microcalcifications were analyzed from April 2012 to September 2014. All patients underwent MRI. All patients with enhancing lesions in the region of the microcalcifications underwent SVAB. Non-enhancing lesions were followed or biopsied, depending on the patient's preferences. MRI findings were classified as either malignant-suspicious or benign-suspicious (“none” or “nonspecific”), and we evaluated the positive predictive value (PPV) and negative predictive value (NPV) of these classifications for predicting malignancy. Results A total of 87 patients underwent both MRI and SVAB. The NPV of MRI was 100% in the group with no enhancement. In BI-RADS category 3, there were 57 benign-suspicious lesions on MRI, of which eight were malignant (NPV of MRI: 85.0%). Conclusions It may be possible to omit SVAB for microcalcifications if there is no enhancement on MRI; however, any kind of enhancement indicates the need for biopsy in cases of BI-RADS 3 calcifications on MG. PMID:28861368
Yatake, Hidetoshi; Sawai, Yuka; Nishi, Toshio; Nakano, Yoshiaki; Nishimae, Ayaka; Katsuda, Toshizo; Yabunaka, Koichi; Takeda, Yoshihiro; Inaji, Hideo
2017-07-01
The objective of the study was to compare direct measurement with a conventional method for evaluation of clip placement in stereotactic vacuum-assisted breast biopsy (ST-VAB) and to evaluate the accuracy of clip placement using the direct method. Accuracy of clip placement was assessed by measuring the distance from a residual calcification of a targeted calcification clustered to a clip on a mammogram after ST-VAB. Distances in the craniocaudal (CC) and mediolateral oblique (MLO) views were measured in 28 subjects with mammograms recorded twice or more after ST-VAB. The difference in the distance between the first and second measurements was defined as the reproducibility and was compared with that from a conventional method using a mask system with overlap of transparent film on the mammogram. The 3D clip-to-calcification distance was measured using the direct method in 71 subjects. The reproducibility of the direct method was higher than that of the conventional method in CC and MLO views (P = 0.002, P < 0.001). The median 3D clip-to-calcification distance was 2.8 mm, with an interquartile range of 2.0-4.8 mm and a range of 1.1-36.3 mm. The direct method used in this study was more accurate than the conventional method, and gave a median 3D distance of 2.8 mm between the calcification and clip.
Li, John; Weissberg, Zoe; Bevilacqua, Thomas A; Yu, Gordon; Weber, Kristy; Sebro, Ronnie
2018-04-01
To compare the concordance between fine-needle aspiration and core biopsies for osseous lesions by lesion imaging appearance and CT attenuation. Retrospective review of 215 FNAs of osseous lesions performed in conjunction with core biopsy at our institution over a 6-year period (2011-2016). FNAs were interpreted independently of core biopsies. We assessed if FNA in conjunction with core biopsy increased diagnostic accuracy compared to core biopsy alone. We also calculated the concordance between FNA and core biopsy by lesion appearance, lesion CT attenuation, lesion histology, lesion location and FNA needle gauge size. Core biopsy alone provided the diagnosis in 207/215 cases (96.3%), however, the FNA provided the diagnosis in the remaining 8/215 cases (3.7%) where the core biopsy was non-diagnostic. There were 154 (71.6%) lytic lesions, 21 (9.8%) blastic lesions, 25 (11.6%) mixed lytic and blastic lesions and 15 (7.0%) lesions that were neither lytic nor blastic. The concordance between FNA and core biopsy for lytic osseous lesions (136/154 cases, 88.3%) was statistically significantly higher than that for blastic osseous lesions (13/21 cases, 61.9%) [P = 4.2 × 10 -3 ; 95% CI (0.02, 0.50)]. The concordance between FNA and core biopsy was higher for low-attenuation- (110/126) than high-attenuation (58/77) lesions (P = 0.028). The concordance between FNA and core biopsy was also higher for metastases (102/119 cases, 85.7%) than non-metastases (78/96, 81.3%) [P = 0.487; 95% CI (- 0.15, 0.065)]. There was no difference in the rate of concordance between FNA and core biopsy by lesion location or FNA needle gauge size (P > 0.05). FNA with core biopsy increases diagnostic rate compared to core biopsy alone or FNA alone. The concordance between FNA and core biopsy is higher for lytic lesions than for blastic lesions; and higher for low-attenuation lesions than for high-attenuation lesions.
Chae, In Hye; Kim, Eun-Kyung; Moon, Hee Jung; Yoon, Jung Hyun; Park, Vivian Y; Kwak, Jin Young
2017-07-01
To compare post-biopsy hematoma rates between ultrasound guided-fine needle aspiration and ultrasound guided-core needle biopsy, and to investigate risk factors for post-biopsy hematoma. A total of 5304 thyroid nodules which underwent ultrasound guided biopsy were included in this retrospective study. We compared clinical and US features between patients with and without post-biopsy hematoma. Associations between these features and post-biopsy hematoma were analyzed. Post-biopsy hematoma rate was 0.8% (43/5121) for ultrasound guided-fine needle aspiration and 4.9% (9/183) for ultrasound guided-core needle biopsy (P < 0.001). For ultrasound guided-fine needle aspiration, gender, age, size, presence of vascularity, and suspicious US features were not associated with post-biopsy hematoma according to experience level. Post-biopsy hematoma occurred significantly more with ultrasound guided-core needle biopsy (9/179, 5.0%) than with ultrasound guided-fine needle aspiration (9/1138, 0.8%) (P < 0.001) in experienced performers and ultrasound guided-core needle biopsy was the only significant risk factor for post-biopsy hematoma (adjusted Odds Ratio, 6.458, P < 0.001). Post-biopsy hematoma occurred significantly more in ultrasound guided-core needle biopsy than in ultrasound guided-fine needle aspiration and ultrasound guided-core needle biopsy was the only independent factor of post-biopsy hematoma in thyroid nodules.
Prakash, V. Surya; Mohan, G. Chandra; Krishnaiah, S. Venkata; Vijaykumar, V.; Babu, G. Ramesh; Reddy, G. Vijaya Bhaskar; Mahaboob, V. S.
2013-01-01
Purpose: To compare the cancer detection rate in patients with raised serum prostate-specific antigen (PSA) or abnormal digital rectal examination (DRE) results between the 10-core and the 16-core biopsy techniques in an Indian population. Methods: Between November 2010 and November 2012, 95 men aged >50 years who presented to the Urology Department with lower urinary tract symptoms, elevated serum PSA, and/or abnormal DRE findings underwent transrectal ultrasonography (TRUS)-guided prostate biopsy. A total of 53 patients underwent 10-core biopsy and 42 patients underwent 16-core biopsy. Results: Of the 53 men in the 10-core group, 8 had cancer, whereas in the 16-core biopsy group, 23 of 42 men had cancer. Detection of prostate cancer was significantly higher in patients who underwent 16-core biopsy than in those who underwent 10-core biopsy (P<0.001). Among the 95 men, 44 men had abnormal DRE findings (46.3%), of whom 23 showed cancer (52.27%). Of 51 men with normal DRE findings and elevated PSA, 8 men had malignancy with a cancer detection rate of 15.68%. Among 20 men with PSA between 4.1 and 10 ng/mL, 2 (10%) had cancer. In 31 men with PSA between 10.1 and 20 ng/mL, 3 cancers (9.67%) were detected, and in 44 men with PSA >20 ng/mL, 26 cancers were detected (59.09%). Conclusions: The cancer detection rate with 16-core TRUS-guided biopsy is significantly higher than that with 10-core biopsy (54.76% vs. 15.09%, P<0.001). In patients with both normal and abnormal DRE findings, 16-core biopsy has a better detection rate than the 10-core biopsy protocol. With increasing PSA, there is a high rate of detection of prostate cancer in both 10-core and 16-core biopsy patients. PMID:24392441
Prakash, V Surya; Mohan, G Chandra; Krishnaiah, S Venkata; Vijaykumar, V; Babu, G Ramesh; Reddy, G Vijaya Bhaskar; Mahaboob, V S
2013-01-01
To compare the cancer detection rate in patients with raised serum prostate-specific antigen (PSA) or abnormal digital rectal examination (DRE) results between the 10-core and the 16-core biopsy techniques in an Indian population. Between November 2010 and November 2012, 95 men aged >50 years who presented to the Urology Department with lower urinary tract symptoms, elevated serum PSA, and/or abnormal DRE findings underwent transrectal ultrasonography (TRUS)-guided prostate biopsy. A total of 53 patients underwent 10-core biopsy and 42 patients underwent 16-core biopsy. Of the 53 men in the 10-core group, 8 had cancer, whereas in the 16-core biopsy group, 23 of 42 men had cancer. Detection of prostate cancer was significantly higher in patients who underwent 16-core biopsy than in those who underwent 10-core biopsy (P<0.001). Among the 95 men, 44 men had abnormal DRE findings (46.3%), of whom 23 showed cancer (52.27%). Of 51 men with normal DRE findings and elevated PSA, 8 men had malignancy with a cancer detection rate of 15.68%. Among 20 men with PSA between 4.1 and 10 ng/mL, 2 (10%) had cancer. In 31 men with PSA between 10.1 and 20 ng/mL, 3 cancers (9.67%) were detected, and in 44 men with PSA >20 ng/mL, 26 cancers were detected (59.09%). The cancer detection rate with 16-core TRUS-guided biopsy is significantly higher than that with 10-core biopsy (54.76% vs. 15.09%, P<0.001). In patients with both normal and abnormal DRE findings, 16-core biopsy has a better detection rate than the 10-core biopsy protocol. With increasing PSA, there is a high rate of detection of prostate cancer in both 10-core and 16-core biopsy patients.
Schiaffino, Simone; Gristina, Licia; Villa, Alessandro; Tosto, Simona; Monetti, Francesco; Carli, Franca; Calabrese, Massimo
2018-01-01
To determine the malignancy rate (defined in this study as stability or absence of malignancy developed on close imaging follow-up post-biopsy) of conservative management in patients with a vacuum-assisted breast biopsy (VAB) diagnosis of flat epithelial atypia (FEA), performed on single group of microcalcifications, completely removed during procedure. This is a retrospective, monocentric, observational study, approved by IRB. Inclusion criteria were: VAB performed on a single group of microcalcifications; the absence of residual calcifications post-VAB; diagnosis of isolated FEA as the most advanced proliferative lesion; radiological follow-up at least of 12 months. The personal history of breast cancer or other high-risk lesions was an exclusion criteria. The patients enrolled were conservatively managed, without surgical excision, through close follow-up: the first two mammographies performed with an interval of 6 months after biopsy, followed by annual mammographic and clinical checks. 48 consecutive patients were enrolled in the study, all females, with age range of 39-76 years (mean 53,3 years) and radiological follow-up range of 13-75 months (mean 41.5 months). All the lesions were classified as BI-RADS 4b. The diameter range of the group of calcifications was 3-10 mm (mean 5, 6 mm). In each patient, 7 to 15 samples (mean 11) were obtained. Among all the patients, there was only one case (2%) of new microcalcifications, developed in the same breast, 26 months after and 8 mm from the site of previous VAB, and interpreted as ADH at surgical excision. All the checks of the other patients were negative. Even with a limited follow-up, we found a malignancy rate lower than 2%, through a defined population. Further studies with bigger number of patients and extended follow-up are needed to reinforce this hypothesis. Advances in knowledge: Surgical excision may not be necessary in patients with VAB diagnosis of isolated FEA, without residual microcalcifications post-procedure and considered concordant with the mammographic presentation, considering the low rate of malignancy at subsequent follow-ups.
Overduin, Christiaan G; Heidkamp, Jan; Rothgang, Eva; Barentsz, Jelle O; de Lange, Frank; Fütterer, Jurgen J
2018-05-22
To assess the feasibility of adding a tablet device inside the scanner room to assist needle-guide alignment during magnetic resonance (MR)-guided transrectal prostate biopsy. Twenty patients with one cancer-suspicious region (CSR) with PI-RADS score ≥ 4 on diagnostic multiparametric MRI were prospectively enrolled. Two orthogonal scan planes of an MR fluoroscopy sequence (~3 images/s) were aligned to the CSR and needle-guide pivoting point. Targeting was achieved by manipulating the needle-guide under MR fluoroscopy feedback on the in-room tablet device. Technical feasibility and targeting success were assessed. Complications and biopsy procedure times were also recorded. Needle-guide alignment with the in-room tablet device was technically successful in all patients and allowed sampling after a single alignment step in 19/20 (95%) CSRs (median size 14 mm, range: 4-45). Biopsy cores contained cancer in 18/20 patients. There were no per-procedural or post-biopsy complications. Using the tablet device, the mean time to first biopsy was 5.8 ± 1.0 min and the mean total procedure time was 23.7 ± 4.1 min. Use of an in-room tablet device to assist needle-guide alignment was feasible and safe during MR-guided transrectal prostate biopsy. Initial experience indicates potential for procedure time reduction. • Performing MR-guided prostate biopsy using an in-room tablet device is feasible. • CSRs could be sampled after a single alignment step in 19/20 patients. • The mean procedure time for biopsy with the tablet device was 23.7 min.
Otsuka, Masafumi; Kamasako, Tomohiko; Uemura, Toshihiro; Takeshita, Nobushige; Shinozaki, Tetsuo; Kobayashi, Masayuki; Komaru, Atsushi; Fukasawa, Satoshi
2018-06-19
The effectiveness of cancer control is unclear after radical prostatectomy for patients with clinical T3 prostate cancer. We retrospectively reviewed 1409 patients who underwent radical prostatectomy between April 2007 and December 2014, including 210 patients with cT3 prostate cancer. Nine patients who received neoadjuvant hormonal therapy and three patients who were lost to follow-up were excluded from the analysis. Clinical staging was performed by an experienced radiologist using preoperative magnetic resonance imaging findings. We analyzed the predictors of biochemical recurrence using Cox proportional hazard analyses. A total of 113 patients (57%) underwent radical retropubic prostatectomy and 85 patients (43%) underwent robot-assisted radical prostatectomy. The median follow-up period was 36 months. Downstaging occurred for 60 patients (30%), positive surgical margins were identified in 117 patients (59%), and biochemical recurrence was observed for 89 patients (45%). In the multivariate analyses, the independent preoperative predictors of biochemical recurrence were ≥50% proportion of positive biopsy cores [hazard ratio (HR): 2.858, P < 0.0001] and a biopsy Gleason score of ≥8 (HR: 1.800, P = 0.0093). The independent post-operative predictors of biochemical recurrence were positive surgical margins (HR: 2.490, P = 0.0018) and seminal vesicle invasion (HR: 2.750, P < 0.0001). Among patients with cT3 prostate cancer, the percentage of positive biopsy cores and the biopsy Gleason score should be considered to select treatment. Compared with radical retropubic prostatectomy, robot-assisted radical prostatectomy may be a feasible treatment option in this setting.
... needle biopsy procedures include fine-needle aspiration and core needle biopsy. Needle biopsy may be used to ... hollow needle to draw cells from your body. Core needle biopsy. This type of needle biopsy uses ...
Farshid, Gelareh; Downey, Peter; Pieterse, Steve; Gill, P Grantley
2017-09-01
Technical advances have improved the detection of small mammographic lesions. In the context of mammographic screening, accurate sampling of these lesions by percutaneous biopsy is crucial in limiting diagnostic surgical biopsies, many of which show benign results. Women undergoing core biopsy between January 1997 and December 2007 for <10-mm lesions are included. Patient demographics, imaging features and final histology were tabulated. Performance indices were evaluated. This audit includes 803 lesions <10 mm. Based on core histology, 345 women (43.0%) were immediately cleared of malignancy and 300 (37.4%) were referred for definitive cancer treatment. A further 157 women (19.6%) required diagnostic surgical biopsy because of indefinite or inadequate core results or radiological-pathological discordance, and one woman (0.1%) needed further imaging in 12 months. The open biopsies were malignant in 46 (29.3%) cases. The positive predictive value of malignant core biopsy was 100%. The negative predictive value for benign core results was 97.7%, and the false-negative rate was 2.6%. The lesion could not be visualized after core biopsy in 5.1% of women and in 4.0% of women with malignant core biopsies excision specimens did not contain residual malignancy. Excessive delays in surgery because of complications of core biopsy were not reported. Even at this small size range, core biopsy evaluation of screen-detected breast lesions is highly effective and accurate. A lesion miss rate of 3.1% and under-representation of lesions on core samples highlight the continued need for multidisciplinary collaboration and selective use of diagnostic surgical biopsy. © 2015 Royal Australasian College of Surgeons.
Granulomatous mastitis: changing clinical and imaging features with image-guided biopsy correlation.
Handa, Priyanka; Leibman, A Jill; Sun, Derek; Abadi, Maria; Goldberg, Aryeh
2014-10-01
To review clinical presentation, revisit patient demographics and imaging findings in granulomatous mastitis and determine the optimal biopsy method for diagnosis. A retrospective study was performed to review the clinical presentation, imaging findings and biopsy methods in patients with granulomatous mastitis. Twenty-seven patients with pathology-proven granulomatous mastitis were included. The average age at presentation was 38.0 years (range, 21-73 years). Seven patients were between 48 and 73 years old. Twenty-four patients presented with symptoms and three patients were asymptomatic. Nineteen patients were imaged with mammography demonstrating mammographically occult lesions as the predominant finding. Twenty-six patients were imaged with ultrasound and the most common finding was a mass lesion. Pathological diagnosis was made by image-guided biopsy in 44 % of patients. The imaging features of granulomatous mastitis on mammography are infrequently described. Our study demonstrates that granulomatous mastitis can occur in postmenopausal or asymptomatic patients, although previously reported exclusively in young women with palpable findings. Presentation on mammography as calcifications requiring mammographically guided vacuum-assisted biopsy has not been previously described. The diagnosis of granulomatous mastitis can easily be made by image-guided biopsy and surgical excision should be reserved for definitive treatment. • Characterizes radiographic appearance of granulomatous mastitis in postmenopausal or asymptomatic patients. • Granulomatous mastitis can present exclusively as calcifications on mammography. • The diagnosis of granulomatous mastitis is made by image-guided biopsy techniques.
Tang, Jing-Hua; An, Xin; Lin, Xi; Gao, Yuan-Hong; Liu, Guo-Chen; Kong, Ling-Heng; Pan, Zhi-Zhong; Ding, Pei-Rong
2015-10-20
Patients with pathological complete remission (pCR) after treated with neoadjuvant chemoradiotherapy (nCRT) have better long-term outcome and may receive conservative treatments in locally advanced rectal cancer (LARC). The study aimed to evaluate the value of forceps biopsy and core needle biopsy in prediction of pCR in LARC treated with nCRT. In total, 120 patients entered this study. Sixty-one consecutive patients received preoperative forceps biopsy during endoscopic examination. Ex vivo core needle biopsy was performed in resected specimens of another 43 consecutive patients. The accuracy for ex vivo core needle biopsy was significantly higher than forceps biopsy (76.7% vs. 36.1%; p < 0.001). The sensitivity for ex vivo core needle biopsy was significantly lower in good responder (TRG 3) than poor responder (TRG ≤ 2) (52.9% vs. 94.1%; p = 0.017). In vivo core needle biopsy was further performed in 16 patients with good response. Eleven patients had residual cancer cells in final resected specimens, among whom 4 (36.4%) patients were biopsy positive. In conclusion, routine forceps biopsy was of limited value in identifying pCR after nCRT. Although core needle biopsy might further identify a subset of patients with residual cancer cells, the accuracy was not substantially increased in good responders.
Gao, Yuan-Hong; Liu, Guo-Chen; Kong, Ling-Heng; Pan, Zhi-Zhong; Ding, Pei-Rong
2015-01-01
Patients with pathological complete remission (pCR) after treated with neoadjuvant chemoradiotherapy (nCRT) have better long-term outcome and may receive conservative treatments in locally advanced rectal cancer (LARC). The study aimed to evaluate the value of forceps biopsy and core needle biopsy in prediction of pCR in LARC treated with nCRT. In total, 120patients entered this study. Sixty-one consecutive patients received preoperative forceps biopsy during endoscopic examination. Ex vivo core needle biopsy was performed in resected specimens of another 43 consecutive patients. The accuracy for ex vivo core needle biopsy was significantly higher than forceps biopsy (76.7% vs. 36.1%; p < 0.001). The sensitivity for ex vivo core needle biopsy was significantly lower in good responder (TRG 3) than poor responder (TRG ≤ 2) (52.9% vs. 94.1%; p = 0.017). In vivo core needle biopsy was further performed in 16 patients with good response. Eleven patients had residual cancer cells in final resected specimens, among whom 4 (36.4%) patients were biopsy positive. In conclusion, routine forceps biopsy was of limited value in identifying pCR after nCRT. Although core needle biopsy might further identify a subset of patients with residual cancer cells, the accuracy was not substantially increased in good responders. PMID:26416245
Hashimoto, Kohei; Shinkai, Nobuo; Tanaka, Toshiaki; Masumori, Naoya
2017-06-01
We investigated diagnostic yield of initial biopsy and repeated biopsy including apical cores. We investigated 573 consecutive men with PSA of ≤20 ng/ml who underwent prostate biopsy between 2004 and 2013. The initial 14-core biopsy consisted of the sextant type, lateral sites at the base and middle, lateral apices (la) at anterior horn sites, and apical anterior sites (aa). The repeated 18-core biopsy consisted of the initial 14-core biopsy with four transition zone (TZ) sites at the base (tzb) and middle (tzm). Prostate cancer was diagnosed in 178 (38.9%) of 458 men with the initial 14-core biopsy, and 44 (38.3%) of 115 men with the repeated 18-core biopsy. In the initial biopsy setting, the unique cancer detection rate was high in apical sites (apex, la, and aa: 6.2%, 6.2% and 5.1%, respectively). In the repeated setting, it was high in the TZ site in addition to the apical site (apex, la, aa, tzm, and tzb: 6.8%, 6.8%, 11.4%, 9.1% and 11.4%, respectively). The positive SM rate at the apex was higher in patients whose cancer was detected only in sites other than the sextant region than for those in the sextant region (36.4% vs. 14.8%, P = 0.037). The initial 14-core and the repeated 18-core biopsy scheme including apical anterior cores are feasible for prostate cancer detection. We propose that apical biopsy cores can be used to predict not only the existence of cancer but also surgical margin status at the apex. © The Author 2017. Published by Oxford University Press. All rights reserved. For permissions, please e-mail: journals.permissions@oup.com.
Kim, Ji Won; Park, Hyoung Keun; Kim, Hyeong Gon; Ham, Dong Yeub; Paick, Sung Hyun; Lho, Yong Soo; Choi, Woo Suk
2015-10-01
We compared location of positive cores in biopsy and location of positive surgical margin (PSM) following radical prostatectomy. This retrospective analysis included patients who were diagnosed as prostate cancer by standard 12-core transrectal ultrasonography guided prostate biopsy, and who have PSM after radical prostatectomy. After exclusion of number of biopsy cores <12, and lack of biopsy location data, 46 patients with PSM were identified. Locations of PSM in pathologic specimen were reported as 6 difference sites (apex, base and lateral in both sides). Discordance of biopsy result and PSM was defined when no positive cores in biopsy was identified at the location of PSM. Most common location of PSM were right apex (n=21) and left apex (n=15). Multiple PSM was reported in 21 specimens (45.7%). In 32 specimens (69.6%) with PSM, one or more concordant positive biopsy cores were identified, but 14 specimens (28%) had no concordant biopsy cores at PSM location. When discordant rate was separated by locations of PSM, right apex PSM had highest rate of discordant (38%). The discordant group had significantly lower prostate volume and lower number of positive cores in biopsy than concordant group. This study showed that one fourth of PSM occurred at location where tumor was not detected at biopsy and that apex PSM had highest rate of discordant. Careful dissection to avoid PSM should be performed in every location, including where tumor was not identified in biopsy.
49 CFR 570.56 - Vacuum brake assist unit and vacuum brake system.
Code of Federal Regulations, 2010 CFR
2010-10-01
.... The following requirements apply to vehicles with vacuum brake assist units and vacuum brake systems. (a) Vacuum brake assist unit integrity. The vacuum brake assist unit shall demonstrate integrity as... maintained on the pedal. (1) Inspection procedure. Stop the engine and apply service brake several times to...
Mayer, Sebastian; Kayser, Gian; Rücker, Gerta; Bögner, Diana; Hirschfeld, Marc; Hug, Christiane; Stickeler, Elmar; Gitsch, Gerald; Erbes, Thalia
2017-02-01
Lesions of uncertain malignant potential (B3) represent a heterogeneous group with an overall risk for malignancy of 9.85-35.1% after total resection. Positive predictive values (PPV) for malignancy vary depending on B3 subtype. The aim of this study was to evaluate the PPV for malignancy in B3 lesions and to determine the clinical significance of atypia-dependent sub-classification (a = without epithelial atypia; b = with epithelial atypia) of B3 into B3a and B3b and papillary lesions (PL) in PLa and PLb. 219 patients with histopathologically proven B3 lesions on core needle/vacuum-assisted biopsy who subsequently underwent diagnostic excision biopsy were included in this study. PPVs for malignancy were reported for B3 in general and all B3 sub-categories. Logistic regression analysis identified associations between B3-subgroups and outcome after excision biopsy as well as the impact of clinical and diagnostic findings on excision diagnosis. The overall PPV rate was 10.0% (22/219). Excision histology exhibited a higher malignancy rate in PLb (2/7; PPV: 28.6%) than in PLa (6/127; PPV: 4.7%) (p = 0.057) and in B3b (12/50; PPV: 24.0%) compared to B3a category (8/165; PPV: 4.8%) (p < 0.001). These findings support the necessity of B3 lesion sub-classification into B3a and B3b and of PL into PLa and PLb when considering epithelial atypia. The determination of atypia status represents a relevant factor in risk-stratification for clinical management of B3 lesions. Should future studies using the sub-classification of PL confirm these results, observation may be a safe option for the clinical management of patients with asymptomatic PLa lesions. Copyright © 2016 Elsevier Ltd. All rights reserved.
Bramley, Kyle; Pisani, Margaret A; Murphy, Terrence E; Araujo, Katy L; Homer, Robert J; Puchalski, Jonathan T
2016-05-01
Endobronchial ultrasound (EBUS)-guided transbronchial needle aspiration (TBNA) is important in the evaluation of thoracic lymphadenopathy. Reliably providing excellent diagnostic yield for malignancy, its diagnosis of sarcoidosis is inconsistent. Furthermore, TBNA may not suffice when larger "core biopsy" samples of malignant tissue are required. The primary objective of this study was to determine if the sequential use of TBNA and a novel technique called cautery-assisted transbronchial forceps biopsy (ca-TBFB) was safe. Secondary outcomes included sensitivity and successful acquisition of tissue. The study prospectively enrolled 50 unselected patients undergoing convex-probe EBUS. All lymph nodes exceeding 1 cm were sequentially biopsied under EBUS guidance using TBNA and ca-TBFB. Safety and sensitivity were assessed at the nodal level for 111 nodes. Results of each technique were also reported for each patient. There were no significant adverse events. In nodes determined to be malignant, TBNA provided higher sensitivity (100%) than ca-TBFB (78%). However, among nodes with granulomatous inflammation, ca-TBFB exhibited higher sensitivity (90%) than TBNA (33%). On the one hand, for analysis based on patients rather than nodes, 6 of the 31 patients with malignancy would have been missed or understaged if the diagnosis were based on samples obtained by ca-TBFB. On the other hand, 3 of 8 patients with sarcoidosis would have been missed if analysis were based only on TBNA samples. In some patients, only ca-TBFB acquired sufficient tissue for the core samples needed in clinical trials of malignancy. The sequential use of TBNA and ca-TBFB appears to be safe. The larger samples obtained from ca-TBFB increased its sensitivity to detect granulomatous disease and provided adequate specimens for clinical trials of malignancy when specimens from needle biopsies were insufficient. For thoracic surgeons and advanced bronchoscopists, we advocate ca-TBFB as an alternative to TBNA in select clinical scenarios. Copyright © 2016 The Society of Thoracic Surgeons. Published by Elsevier Inc. All rights reserved.
Are 10-, 10-12-, or > 12-mm prostate biopsy core quality control cutoffs reasonable?
Sanches, Brunno C F; Lalli, Ana Luiza; Azal Neto, Wilmar; Billis, Athanase; Reis, Leonardo Oliveira
2018-07-01
To explore the role of prostate biopsy core length on prediction of index tumor clinical significance and localization on radical prostatectomy (RP) and time to recurrence, hypothesizing 10-, 10-12-, or > 12-mm minimum core as potential biopsy quality control. Assessed 2424 prostate biopsy cores and corresponding RP of 202 patients submitted to the first set of 12 cores prostate biopsy between 2010 and 2015. Analyzed biopsy core length, age, prostate volume (PV), free and total PSA ratio, PSA density, RP index tumor clinical significance, extension, localization, surgical margins, and cancer control. Prostate biopsy confronted to surgical specimens defined Gleason grade-grouping system (1-5) agreement. Median age was 63.7 years, PSA 10.1 ng/dl, PSA density 28%, and mean follow-up 5 years. Recurrence was identified in 64 (31.7%) patients and predicted by PSA > 10 at time of diagnosis (p = 0.008), seminal vesicle invasion (p = 0.0019), core tumor percentage (p = 0.033), and tumor localization predominantly in the prostate base (p = 0017). The mean core length was longer in index tumor positive cores (p = 0.043) and in tumors classified as clinically insignificant (p = 0.011), without impact on tumor localization (basal vs apical p = 0.592; left vs. right p = 0.320). Biopsy core length categories (≤ 10, 10-12 and > 12 mm) did not significantly impact Gleason grade-grouping agreement or time to recurrence (p > 0.05). Core length was not significantly different in all Gleason grade-groupings 1-5 (p = 0.312). Prostate biopsy core length impacts tumor characterization; however, 10 mm minimum core length and even 10-12- and > 12-mm categories failed as a biopsy quality control in our data.
21 CFR 864.9125 - Vacuum-assisted blood collection system.
Code of Federal Regulations, 2010 CFR
2010-04-01
... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Vacuum-assisted blood collection system. 864.9125... Blood and Blood Products § 864.9125 Vacuum-assisted blood collection system. (a) Identification. A vacuum-assisted blood collection system is a device intended for medical purposes that uses a vacuum to...
21 CFR 864.9125 - Vacuum-assisted blood collection system.
Code of Federal Regulations, 2013 CFR
2013-04-01
... 21 Food and Drugs 8 2013-04-01 2013-04-01 false Vacuum-assisted blood collection system. 864.9125... Blood and Blood Products § 864.9125 Vacuum-assisted blood collection system. (a) Identification. A vacuum-assisted blood collection system is a device intended for medical purposes that uses a vacuum to...
21 CFR 864.9125 - Vacuum-assisted blood collection system.
Code of Federal Regulations, 2014 CFR
2014-04-01
... 21 Food and Drugs 8 2014-04-01 2014-04-01 false Vacuum-assisted blood collection system. 864.9125... Blood and Blood Products § 864.9125 Vacuum-assisted blood collection system. (a) Identification. A vacuum-assisted blood collection system is a device intended for medical purposes that uses a vacuum to...
21 CFR 864.9125 - Vacuum-assisted blood collection system.
Code of Federal Regulations, 2012 CFR
2012-04-01
... 21 Food and Drugs 8 2012-04-01 2012-04-01 false Vacuum-assisted blood collection system. 864.9125... Blood and Blood Products § 864.9125 Vacuum-assisted blood collection system. (a) Identification. A vacuum-assisted blood collection system is a device intended for medical purposes that uses a vacuum to...
21 CFR 864.9125 - Vacuum-assisted blood collection system.
Code of Federal Regulations, 2011 CFR
2011-04-01
... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Vacuum-assisted blood collection system. 864.9125... Blood and Blood Products § 864.9125 Vacuum-assisted blood collection system. (a) Identification. A vacuum-assisted blood collection system is a device intended for medical purposes that uses a vacuum to...
All atypia diagnosed at stereotactic vacuum-assisted breast biopsy do not need surgical excision.
de Mascarel, Isabelle; Brouste, Véronique; Asad-Syed, Maryam; Hurtevent, Gabrielle; Macgrogan, Gaëtan
2011-09-01
The necessity of excision is debatable when atypia are diagnosed at stereotactic vacuum-assisted breast biopsy (microbiopsy). Among the 287 surgical excisions performed at Institut Bergonié from 1999 to 2009, we selected a case-control study group of 151 excisions; 52 involving all the diagnosed cancers and 99 randomly selected among the 235 excisions without cancer, following atypical microbiopsy (24 flat epithelial atypia; 50 atypical ductal hyperplasia; 14 lobular neoplasia; 63 mixed lesions). Mammographical calcification (type, extension, complete removal) and histological criteria of epithelial atypia (type, number of foci, size/extension), topography and microcalcification extension at microbiopsy were compared according to the presence or absence of cancer at excision. Factors associated with cancer at excision were Breast Imaging Reporting and Data System (BI-RADS5) lesions, large and/or multiple foci of mammographical calcifications, histological type, number, size and extension of atypical foci. Flat epithelial atypia alone was never associated with cancer at excision. BI-RADS5, atypical ductal hyperplasia (alone or predominant) and >3 foci of atypia were identified as independent pejorative factors. There was never any cancer at excision when these pejorative factors were absent (n=31). Presence of one (n=59), two (n=23) or three (n=14) factors was associated with cancer in 24, 15 and 13 cases with an odds ratio=5.8 (95% CI: 3-11.2) for each additional factor. We recommend that mammographical data and histological characteristics be taken into account in the decision-making process after diagnosis of atypia on microbiopsy. With experienced senologists and strict histological criteria, some patients could be spared surgery resulting in significant patient, financial and time advantages.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Bittner, Nathan; Merrick, Gregory S., E-mail: gmerrick@urologicresearchinstitute.or; Galbreath, Robert W.
2010-11-15
Purpose: Standard prostate biopsy schemes underestimate Gleason score in a significant percentage of cases. Extended biopsy improves diagnostic accuracy and provides more reliable prognostic information. In this study, we tested the hypothesis that greater biopsy core number should result in improved treatment outcome through better tailoring of therapy. Methods and Materials: From April 1995 to May 2006, 1,613 prostate cancer patients were treated with permanent brachytherapy. Patients were divided into five groups stratified by the number of prostate biopsy cores ({<=}6, 7-9, 10-12, 13-20, and >20 cores). Biochemical progression-free survival (bPFS), cause-specific survival (CSS), and overall survival (OS) were evaluatedmore » as a function of core number. Results: The median patient age was 66 years, and the median preimplant prostate-specific antigen was 6.5 ng/mL. The overall 10-year bPFS, CSS, and OS were 95.6%, 98.3%, and 78.6%, respectively. When bPFS was analyzed as a function of core number, the 10-year bPFS for patients with >20, 13-20, 10-12, 7-9 and {<=}6 cores was 100%, 100%, 98.3%, 95.8%, and 93.0% (p < 0.001), respectively. When evaluated by treatment era (1995-2000 vs. 2001-2006), the number of biopsy cores remained a statistically significant predictor of bPFS. On multivariate analysis, the number of biopsy cores was predictive of bPFS but did not predict for CSS or OS. Conclusion: Greater biopsy core number was associated with a statistically significant improvement in bPFS. Comprehensive regional sampling of the prostate may enhance diagnostic accuracy compared to a standard biopsy scheme, resulting in better tailoring of therapy.« less
Vandervelde, C; Kamani, T; Varghese, A; Ramesar, K; Grace, R; Howlett, D C
2008-04-01
The reason for this study was to evaluate the ability of image-guided core biopsy to replace surgical excision by providing sufficient diagnostic and treatment information. All consecutive image-guided core biopsies in patients with a final diagnosis of lymphoma over a 6-year period at our institution were collected retrospectively. Case notes and pathology reports were reviewed and the diagnostic techniques used were recorded. Pathology reports were graded according to their diagnostic completeness and their ability to provide treatment information. Out of a total of 328 instances of lymphoma, 103 image-guided core biopsies were performed in 96 patients. In 78% of these, the diagnostic information obtained from the biopsy provided a fully graded and subtyped diagnosis of lymphoma with sufficient information to initiate therapy. In the head and neck 67% of core biopsies were fully diagnostic for treatment purposes compared to 91% in the thorax, abdomen and pelvis. Image-guided core biopsy has a number of cost and safety advantages over surgical excision biopsy and in suitable cases it can obviate the need for surgery in cases of suspected lymphoma. This is especially relevant for elderly patients and those with poor performance status.
Real-time three-dimensional optical coherence tomography image-guided core-needle biopsy system.
Kuo, Wei-Cheng; Kim, Jongsik; Shemonski, Nathan D; Chaney, Eric J; Spillman, Darold R; Boppart, Stephen A
2012-06-01
Advances in optical imaging modalities, such as optical coherence tomography (OCT), enable us to observe tissue microstructure at high resolution and in real time. Currently, core-needle biopsies are guided by external imaging modalities such as ultrasound imaging and x-ray computed tomography (CT) for breast and lung masses, respectively. These image-guided procedures are frequently limited by spatial resolution when using ultrasound imaging, or by temporal resolution (rapid real-time feedback capabilities) when using x-ray CT. One feasible approach is to perform OCT within small gauge needles to optically image tissue microstructure. However, to date, no system or core-needle device has been developed that incorporates both three-dimensional OCT imaging and tissue biopsy within the same needle for true OCT-guided core-needle biopsy. We have developed and demonstrate an integrated core-needle biopsy system that utilizes catheter-based 3-D OCT for real-time image-guidance for target tissue localization, imaging of tissue immediately prior to physical biopsy, and subsequent OCT imaging of the biopsied specimen for immediate assessment at the point-of-care. OCT images of biopsied ex vivo tumor specimens acquired during core-needle placement are correlated with corresponding histology, and computational visualization of arbitrary planes within the 3-D OCT volumes enables feedback on specimen tissue type and biopsy quality. These results demonstrate the potential for using real-time 3-D OCT for needle biopsy guidance by imaging within the needle and tissue during biopsy procedures.
Chen, Youdinghuan; Marotti, Jonathan D; Jenson, Erik G; Onega, Tracy L; Johnson, Kevin C; Christensen, Brock C
2017-08-01
The utility and reliability of assessing molecular biomarkers for translational applications on pre-operative core biopsy specimens assume consistency of molecular profiles with larger surgical specimens. Whether DNA methylation in ductal carcinoma in situ (DCIS), measured in core biopsy and surgical specimens are similar, remains unclear. Here, we compared genome-scale DNA methylation measured in matched core biopsy and surgical specimens from DCIS, including specific DNA methylation biomarkers of subsequent invasive cancer. DNA was extracted from guided 2mm cores of formalin fixed paraffin embedded (FFPE) specimens, bisulfite-modified, and measured on the Illumina HumanMethylation450 BeadChip. DNA methylation profiles of core biopsies exhibited high concordance with matched surgical specimens. Within-subject variability in DNA methylation was significantly lower than between-subject variability (all P<2.20E-16). In 641 CpGs whose methylation was related with increased hazard of invasive breast cancer, lower within-subject than between-subject variability was observed in 92.3% of the study participants (P<0.05). Between patient-matched core biopsy and surgical specimens, <0.6% of CpGs measured had changes in median DNA methylation >15%, and a pathway analysis of these CpGs indicated enrichment for genes related with wound healing. Our results indicate that DNA methylation measured in core biopsies are representative of the matched surgical specimens and suggest that DCIS biomarkers measured in core biopsies can inform clinical decision-making. Copyright © 2017 The Authors. Published by Elsevier Inc. All rights reserved.
Total cost comparison of 2 biopsy methods for nonpalpable breast lesions.
Bodai, B I; Boyd, B; Brown, L; Wadley, H; Zannis, V J; Holzman, M
2001-05-01
To identify, quantify, and compare total facility costs for 2 breast biopsy methods: vacuum-assisted biopsy (VAB) and needle-wire-localized open surgical biopsy (OSB). A time-and-motion study was done to identify unit resources used in both procedures. Costs were imputed from published literature to value resources. A comparison of the total (fixed and variable) costs of the 2 procedures was done. A convenience sample of 2 high-volume breast biopsy (both VAB and OSB) facilities was identified. A third facility (OSB only) and 8 other sites (VAB only) were used to capture variation. Staff interviews, patient medical records, and billing data were used to check observed data. One hundred and sixty-seven uncomplicated procedures (71 OSBs, 96 VABs) were observed. Available demographic and clinical data were analyzed to assess selection bias, and sensitivity analyses were done on the main assumptions. The total facility costs of the VAB procedure were lower than the costs of the OSB procedure. The overall cost advantage for using VAB ranges from $314 to $843 per procedure depending on the facility type. Variable cost comparison indicated little difference between the 2 procedures. The largest fixed cost difference was $763. Facilities must consider the cost of new technology, especially when the new technology is as effective as the present technology. The seemingly high cost of equipment might negatively influence a decision to adopt VAB, but when total facility costs were analyzed, the new technology was less costly.
Albisinni, S; Aoun, F; Noel, A; El Rassy, E; Lemort, M; Paesmans, M; van Velthoven, R; Roumeguère, T; Peltier, A
2018-01-01
MRI-guided targeted biopsies are advised in patients who have undergone an initial series of negative systematic biopsies, in whom prostate cancer (PCa) suspicion remains elevated. The aim of the study was to evaluate whether, in men with prior negative prostate biopsies, systematic cores are also warranted at the time of an MRI-targeted repeat biopsy. We enrolled patients with prior negative biopsy undergoing real time MRI/TRUS fusion guided prostate biopsy at our institute between 2014 and 2016. Patients with at least one index lesion on multiparametric MRI were included. All eligible patients underwent both systematic random biopsies (12-14 cores) and targeted biopsies (2-4 cores). The study included 74 men with a median age of 65 years, PSA level of 9.27ng/mL, and prostatic volume of 45ml. The overall PCa detection rate and the clinically significant cancer detection rate were 56.7% and 39.2%, respectively. Targeted cores demonstrated similar clinically significant PCa detection rate compared to systematic cores (33.8% vs. 28.4%, P=0.38) with significantly less tissue sampling. Indeed, a combination approach was significantly superior to a targeted-only in overall PCa detection (+16.7% overall detection rate, P=0.007). Although differences in clinically significant PCa detection were statistically non-significant (P=0.13), a combination approach did allow detecting 7 extra clinically significant PCas (+13.8%). In patients with elevated PSA and prior negative biopsies, concurrent systematic sampling may be needed at the time of targeted biopsy in order to maximize PCa detection rate. Larger studies are needed to validate our findings. 4. Copyright © 2017 Elsevier Masson SAS. All rights reserved.
Eom, H-J; Lee, J H; Ko, M-S; Choi, Y J; Yoon, R G; Cho, K J; Nam, S Y; Baek, J H
2015-06-01
Diagnostic test accuracy studies for ultrasonography-guided fine-needle aspiration and ultrasonography-guided core needle biopsy have shown inconclusive results due to their heterogenous study designs. Our aim was to compare the diagnostic accuracy of ultrasonography-guided fine-needle aspiration versus ultrasonography-guided core needle biopsy for detecting malignant tumors of the salivary gland and for the tissue-specific diagnosis of salivary gland tumors in a single tertiary hospital. This retrospective study was approved by our institutional review board and informed consent was waived. Four hundred twelve patients who underwent ultrasonography-guided fine-needle aspiration (n = 155) or ultrasonography-guided core needle biopsy (n = 257) with subsequent surgical confirmation or clinical follow-up were enrolled. We compared the diagnostic accuracy of ultrasonography-guided fine-needle aspiration and ultrasonography-guided core needle biopsy regarding malignant salivary gland tumors and the correct tissue-specific diagnosis of benign and malignant tumors. We also tested the difference between these procedures according to the operator's experience and lesion characteristics. The inconclusive rates of ultrasonography-guided fine-needle aspiration and ultrasonography-guided core needle biopsy were 19% and 4%, respectively (P < .001). The overall accuracy of ultrasonography-guided core needle biopsy for diagnosing malignant tumors was significantly higher than that of ultrasonography-guided fine-needle aspiration (P = .024). The correct tissue-specific diagnosis rates of ultrasonography-guided fine-needle aspiration and ultrasonography-guided core needle biopsy were 95% versus 97% for benign tumors (P = .648) and 67% versus 80% for malignant tumors (P = .310). Trainees showed significantly lower accuracy with ultrasonography-guided fine-needle aspiration than with ultrasonography-guided core needle biopsy for diagnosing malignant tumors (P = .021). There was no difference between the diagnostic accuracy of ultrasonography-guided fine-needle aspiration and ultrasonography-guided core needle biopsy according to the internal composition of the lesions. There were no complications requiring intervention or hospitalization in our patients. Ultrasonography-guided core needle biopsy is superior to ultrasonography-guided fine-needle aspiration in detecting and characterizing malignant tumors of the salivary gland and could emerge as the diagnostic method of choice for patients presenting with a salivary gland mass. © 2015 by American Journal of Neuroradiology.
Ability of sextant biopsies to predict radical prostatectomy stage.
Wills, M L; Sauvageot, J; Partin, A W; Gurganus, R; Epstein, J I
1998-05-01
There are few studies evaluating multiple variables on sextant biopsies with the intent to predict stage in radical prostatectomy specimens. We studied 113 sextant biopsies with corresponding totally submitted radical prostatectomy specimens. Variables evaluated on sextant biopsies included total length and percent of cancer; maximum length and percent of cancer on one core; location (apex, mid, base); bilaterality; Gleason grade; number of cores involved; serum prostate-specific antigen (PSA) level; and serum PSA density (PSAD). Radical prostatectomy stage was classified as organ versus non-organ confined. The following variables individually correlated with radical prostatectomy stage: total cancer measured in millimeters (P <0.0001) or percent (P <0.0005); biopsy Gleason score (P <0.0001); number of involved cores (P <0.0001); maximum cancer on one core measured in millimeters (P = 0.0001); maximum percent of cancer on one core (P = 0.01); bilaterality (P = 0.01); PSA level (P = 0.03), and PSAD (P = 0.001). The most predictive sets of two variables that correlated with stage included high Gleason score (P <0.0001) combined with numbers of cores involved (P = 0.002). When biopsies had Gleason scores of 6 or less, two or fewer positive cores, and serum PSA of 0 to 4 ng/mL, 89% were organ confined. When biopsies had Gleason scores of 6 or less with two unilaterally positive cores, 87% were organ confined. In biopsies with Gleason scores of 7 or more and more than one positive core, only 10% were organ confined. The most important predictors of stage by sextant needle biopsy evaluation are numbers of cores involved with carcinoma and high Gleason score. Bilaterality and serum PSA values improved prediction in two small subgroups. In 37% of our population we were able to predict with a greater than 87% probability the organ-confined versus non-organ-confined status.
Accuracy and safety of ultrasound-guided percutaneous needle core biopsy of renal masses
Wang, Xianding; Lv, Yuanhang; Xu, Zilin; Aniu, Muguo; Qiu, Yang; Wei, Bing; Li, Xiaohong; Wei, Qiang; Dong, Qiang; Lin, Tao
2018-01-01
Abstract Our aim is to determine the sufficiency, accuracy, and safety of ultrasound-guided percutaneous needle core biopsy of renal masses in Chinese patients. Patients who had undergone ultrasound-guided needle core renal mass biopsy from June 2012 to June 2016 at West China Hospital, China were retrospectively reviewed. The information obtained included demographics, mass-related parameters, biopsy indications, technique, complications, pathologic results, and follow-up. Concordance of surgical resection pathology and follow-up data were assessed. Renal mass biopsies were performed in 106 patients. Thirty-nine (36.8%) were asymptomatic. The male/female ratio was 60/46, with a median age of 49.5 years. Median mass size was 8.1 cm (range 1.8–20). Biopsy was performed through a 16-gauge needle, with median cores of 2 taken (range 1–5). Only one significant biopsy-related complication (hemorrhage requiring transfusion) was encountered. An adequate tissue sample was obtained in 97.2% (103/106) of biopsies. Eighty-seven biopsies (82.1%) showed malignant neoplasms, 16 (15.1%) yielded benignity, and 3 (2.8%) were nondiagnostic. After biopsy, 46 patients (43.4%) underwent surgery. Compared with the subsequent mass resection pathology, the biopsy diagnoses were identical in 43 cases. The accuracy rate of biopsy distinguishing malignant from benign lesions was 99.1%, and the rate for determining tumor histological type (excluding the nondiagnostic biopsies) was 95.1%. The sensitivity and specificity in detecting malignancy were 98.9% and 100%, respectively. In several situations, there is still a role for biopsy before intervention. Percutaneous needle core biopsy under ultrasonography guidance is highly accurate and safe, and can determine the proper management of undefinable masses. PMID:29595650
Lin, Michael; Hair, Clark D.; Green, Linda K.; Vela, Stacie A.; Patel, Kalpesh K.; Qureshi, Waqar A.; Shaib, Yasser H.
2014-01-01
Background: Endoscopic ultrasound (EUS)-guided fine needle aspiration (FNA) with bedside cytopathology is the gold standard for assessment of pancreatic, subepithelial, and other lesions in close proximity to the gastrointestinal tract, but it is time-consuming, has certain diagnostic limitations, and bedside cytopathology is not widely available. Aims: The goal of this study is to compare the diagnostic yield of EUS-guided FNA with on-site cytopathology and EUS-guided core biopsy. Methods: Twenty-six patients with gastrointestinal mass lesions requiring biopsy at a tertiary medical center were included in this retrospective analysis of a prospective cohort. Two core biopsies were taken using a 22 gauge needle followed by FNA guided by a bedside cytopathologist at the same endoscopic session. The diagnostic yield and test characteristics of EUS core biopsy and EUS FNA with bedside cytopathology were examined. Results: The mean number of passes was 3.2 for FNA, and the mean procedure time was 39.4 minutes. The final diagnosis was malignant in 92.3 %. Sensitivity and specificity were 83 % and 100 %, respectively, for FNA, and 91.7 % and 100 %, respectively, for core biopsy. Diagnostic accuracy was 92.3 % for FNA and 84.6 % for core biopsy. The two approaches were in agreement in 88.4 % with a kappa statistic of 0.66 (95 % confidence interval 0.33 – 0.99). Conclusions: An approach using two passes with a core biopsy needle is comparable to the current gold standard of FNA with bedside cytopathology. The performance of two core biopsies is time-efficient and could represent a good alternative to FNA with bedside cytopathology. PMID:26135096
Yarlagadda, Vidhush K.; Lai, Win Shun; Gordetsky, Jennifer B.; Porter, Kristin K.; Nix, Jeffrey W.; Thomas, John V.; Rais-Bahrami, Soroush
2018-01-01
PURPOSE We aimed to investigate the efficiency and cancer detection of magnetic resonance imaging (MRI)/ultrasonography (US) fusion-guided prostate biopsy in a cohort of biopsy-naive men compared with standard-of-care systematic extended sextant transrectal ultrasonography (TRUS)-guided biopsy. METHODS From 2014 to 2016, 72 biopsy-naive men referred for initial prostate cancer evaluation who underwent MRI of the prostate were prospectively evaluated. Retrospective review was performed on 69 patients with lesions suspicious for malignancy who underwent MRI/US fusion-guided biopsy in addition to systematic extended sextant biopsy. Biometric, imaging, and pathology data from both the MRI-targeted biopsies and systematic biopsies were analyzed and compared. RESULTS There were no significant differences in overall prostate cancer detection when comparing MRI-targeted biopsies to standard systematic biopsies (P = 0.39). Furthermore, there were no significant differences in the distribution of severity of cancers based on grade groups in cases with cancer detection (P = 0.68). However, significantly fewer needle cores were taken during the MRI/US fusion-guided biopsy compared with systematic biopsy (63% less cores sampled, P < 0.001) CONCLUSION In biopsy-naive men, MRI/US fusion-guided prostate biopsy offers equal prostate cancer detection compared with systematic TRUS-guided biopsy with significantly fewer tissue cores using the targeted technique. This approach can potentially reduce morbidity in the future if used instead of systematic biopsy without sacrificing the ability to detect prostate cancer, particularly in cases with higher grade disease. PMID:29770762
External validation of urinary PCA3-based nomograms to individually predict prostate biopsy outcome.
Auprich, Marco; Haese, Alexander; Walz, Jochen; Pummer, Karl; de la Taille, Alexandre; Graefen, Markus; de Reijke, Theo; Fisch, Margit; Kil, Paul; Gontero, Paolo; Irani, Jacques; Chun, Felix K-H
2010-11-01
Prior to safely adopting risk stratification tools, their performance must be tested in an external patient cohort. To assess accuracy and generalizability of previously reported, internally validated, prebiopsy prostate cancer antigen 3 (PCA3) gene-based nomograms when applied to a large, external, European cohort of men at risk of prostate cancer (PCa). Biopsy data, including urinary PCA3 score, were available for 621 men at risk of PCa who were participating in a European multi-institutional study. All patients underwent a ≥10-core prostate biopsy. Biopsy indication was based on suspicious digital rectal examination, persistently elevated prostate-specific antigen level (2.5-10 ng/ml) and/or suspicious histology (atypical small acinar proliferation of the prostate, >/= two cores affected by high-grade prostatic intraepithelial neoplasia in first set of biopsies). PCA3 scores were assessed using the Progensa assay (Gen-Probe Inc, San Diego, CA, USA). According to the previously reported nomograms, different PCA3 score codings were used. The probability of a positive biopsy was calculated using previously published logistic regression coefficients. Predicted outcomes were compared to the actual biopsy results. Accuracy was calculated using the area under the curve as a measure of discrimination; calibration was explored graphically. Biopsy-confirmed PCa was detected in 255 (41.1%) men. Median PCA3 score of biopsy-negative versus biopsy-positive men was 20 versus 48 in the total cohort, 17 versus 47 at initial biopsy, and 37 versus 53 at repeat biopsy (all p≤0.002). External validation of all four previously reported PCA3-based nomograms demonstrated equally high accuracy (0.73-0.75) and excellent calibration. The main limitations of the study reside in its early detection setting, referral scenario, and participation of only tertiary-care centers. In accordance with the original publication, previously developed PCA3-based nomograms achieved high accuracy and sufficient calibration. These novel nomograms represent robust tools and are thus generalizable to European men at risk of harboring PCa. Consequently, in presence of a PCA3 score, these nomograms may be safely used to assist clinicians when prostate biopsy is contemplated. Copyright © 2010 European Association of Urology. Published by Elsevier B.V. All rights reserved.
Dynamic Failure of Sandwich Beams With Fluid-Structure Interaction Under Impact Loading
2010-12-01
constructed using vacuum assisted transfer molding , with a 6.35 mm balsa core and symmetrical plain weave 6 oz E-glass skins. The experiment...consisted of three phases. First, using three- point bending, strain rate characteristics were examined both in air and under water. After establishing...understanding of sandwich composite characteristics subjected to underwater impact. 15. NUMBER OF PAGES 57 14. SUBJECT TERMS Sandwich Composite, Low
Thong, Alan E; Shikanov, Sergey; Katz, Mark H; Gofrit, Ofer N; Eggener, Scott; Zagaja, Gregory P; Shalhav, Arieh L; Zorn, Kevin C
2008-12-01
Patients with Gleason score 6 microfocal prostate cancer, defined as 5% or less in 1 biopsy core, are often considered to have favorable disease. Few studies have addressed clinical parameters that predict pathological upgrading or up staging at radical prostatectomy. From a prospective database of 1,271 consecutive robot assisted laparoscopic prostatectomies performed from 2003 to 2008 patients with Gleason score 6 microfocal prostate cancer were identified. Adverse pathological outcome was defined as any upgrading and/or up staging on prostatectomy pathological findings. Multivariate logistic regression was used to evaluate the ability of patient age, clinical stage, the total number of biopsy cores, preoperative prostate specific antigen, prostate volume and pathological prostate specific antigen density to predict adverse pathological outcomes. A total of 192 patients with a median age of 59 years (range 42 to 73) were identified with Gleason score 6 prostate cancer involving 5% or less of 1 biopsy core, including 177 (92%) with clinical T1c disease. Mean +/- SD preoperative prostate specific antigen was 6.0 +/- 3.9 ng/ml (range 0.8 to 35). Overall 42 patients (22%) had adverse pathological outcomes, including upgrading in 35 (18%) and up staging in 16 (8%). Multivariate logistic regression revealed that age more than 65 years and pathological prostate specific antigen density greater than 0.20 ng/ml/gm were predictive of an increased risk of adverse pathological results (p = 0.0081 and 0.0169, respectively). While a microfocus of Gleason score 6 prostate cancer on biopsy is commonly considered low risk disease, there was a greater than 1/5 risk of pathological upgrading and/or up staging. Patients with Gleason score 6 microfocal prostate cancer should be counseled that they may harbor more aggressive disease, especially when pretreatment clinical risk factors are present, such as advanced age or high clinical prostate specific antigen density.
Shakir, Nabeel A; George, Arvin K; Siddiqui, M Minhaj; Rothwax, Jason T; Rais-Bahrami, Soroush; Stamatakis, Lambros; Su, Daniel; Okoro, Chinonyerem; Raskolnikov, Dima; Walton-Diaz, Annerleim; Simon, Richard; Turkbey, Baris; Choyke, Peter L; Merino, Maria J; Wood, Bradford J; Pinto, Peter A
2014-12-01
Prostate specific antigen sensitivity increases with lower threshold values but with a corresponding decrease in specificity. Magnetic resonance imaging/ultrasound targeted biopsy detects prostate cancer more efficiently and of higher grade than standard 12-core transrectal ultrasound biopsy but the optimal population for its use is not well defined. We evaluated the performance of magnetic resonance imaging/ultrasound targeted biopsy vs 12-core biopsy across a prostate specific antigen continuum. We reviewed the records of all patients enrolled in a prospective trial who underwent 12-core transrectal ultrasound and magnetic resonance imaging/ultrasound targeted biopsies from August 2007 through February 2014. Patients were stratified by each of 4 prostate specific antigen cutoffs. The greatest Gleason score using either biopsy method was compared in and across groups as well as across the population prostate specific antigen range. Clinically significant prostate cancer was defined as Gleason 7 (4 + 3) or greater. Univariate and multivariate analyses were performed. A total of 1,003 targeted and 12-core transrectal ultrasound biopsies were performed, of which 564 diagnosed prostate cancer for a 56.2% detection rate. Targeted biopsy led to significantly more upgrading to clinically significant disease compared to 12-core biopsy. This trend increased more with increasing prostate specific antigen, specifically in patients with prostate specific antigen 4 to 10 and greater than 10 ng/ml. Prostate specific antigen 5.2 ng/ml or greater captured 90% of upgrading by targeted biopsy, corresponding to 64% of patients who underwent multiparametric magnetic resonance imaging and subsequent fusion biopsy. Conversely a greater proportion of clinically insignificant disease was detected by 12-core vs targeted biopsy overall. These differences persisted when controlling for potential confounders on multivariate analysis. Prostate cancer upgrading with targeted biopsy increases with an increasing prostate specific antigen cutoff. Above a prostate specific antigen threshold of 5.2 ng/ml most upgrading to clinically significant disease was achieved by targeted biopsy. In our population this corresponded to potentially sparing biopsy in 36% of patients who underwent multiparametric magnetic resonance imaging. Below this value 12-core biopsy detected more clinically insignificant cancer. Thus, the diagnostic usefulness of targeted biopsy is optimized in patients with prostate specific antigen 5.2 ng/ml or greater. Copyright © 2014 American Urological Association Education and Research, Inc. Published by Elsevier Inc. All rights reserved.
Efficiency of Core Biopsy for BI-RADS-5 Breast Lesions.
Wolf, Ronald; Quan, Glenda; Calhoun, Kris; Soot, Laurel; Skokan, Laurie
2008-01-01
Stereotactic biopsy has proven more cost effective for biopsy of lesions associated with moderately suspicious mammograms. Data regarding selection of stereotactic biopsy (CORE) instead of excisional biopsy (EB) as the first diagnostic procedure in patients with nonpalpable breast lesions and highest suspicion breast imaging-reporting and data system (BI-RADS)-5 mammograms are sparse. Records from a regional health system radiology database were screened for mammograms associated with image-guided biopsy. A total of 182 nonpalpable BI-RADS-5 lesions were sampled in 178 patients over 5 years, using CORE or EB. Initial surgical margins, number of surgeries, time from initial procedure to last related surgical procedure, and hospital and professional charges for related admissions were compared using chi-squared, t-test, and Wilcoxon Mann-Whitney tests. A total of 108 CORE and 74 EB were performed as the first diagnostic procedure. Invasive or in situ carcinoma was diagnosed in 156 (86%) of all biopsies, 95 in CORE and 61 in EB groups. Negative margins of the first surgical procedure were more frequent in CORE (n = 70, 74%) versus EB (n = 17, 28%), p < 0.05. Use of CORE was associated with fewer total surgical procedures per lesion (1.29 +/- 0.05 versus 1.8 +/- 0.05, p < 0.05). Time of initial diagnostic procedure to final treatment did not vary significantly according to group (27 +/- 2 days versus 22 +/- 2 days, CORE versus EB). Mean charges including the diagnostic procedure and all subsequent surgeries were not different between CORE and EB groups ($10,500 +/- 300 versus $11,500 +/- 500, p = 0.08). Use of CORE as the first procedure in patients with highly suspicious mammograms is associated with improved pathologic margins and need for fewer surgical procedures than EB, and should be considered the preferred initial diagnostic approach.
Increased detection of precancerous cervical lesions with adjunctive dynamic spectral imaging.
DeNardis, Sara A; Lavin, Philip T; Livingston, Jeff; Salter, William R; James-Patrick, Nanette; Papagiannakis, Emmanouil; Olson, Christopher G; Weinberg, Lori
2017-01-01
To validate, in US community-based colposcopy clinics, previous reports of increased detection of high-grade cervical intraepithelial neoplasia (CIN2+) with biopsies selected using dynamic spectral imaging (DSI) mapping after standard colposcopy. Cross-sectional observational study of 26 colposcopists across nine clinics recruiting consecutive colposcopy patients. Standard assessment with biopsy selections was completed before seeing the DSI map which was subsequently interpreted and used for additional biopsies per clinical judgment. Primary measure was the number of women with CIN2+ detected by DSI-assisted biopsies, over those detected by standard colposcopy biopsies. A total of 887 women were recruited. After exclusions, 881 women and 1,189 biopsies were analyzed. Standard biopsy detected 78 women with CIN2+ and DSI-assisted biopsies another 34, increasing the detection rate from 8.85% to 12.71% ( p =0.00016). This was achieved with 16.16% of DSI-assisted biopsies finding CIN2+ compared to 13.24% for the preceding standard biopsies. For secondary specificity analysis, 431 women had only
Increased detection of precancerous cervical lesions with adjunctive dynamic spectral imaging
DeNardis, Sara A; Lavin, Philip T; Livingston, Jeff; Salter, William R; James-Patrick, Nanette; Papagiannakis, Emmanouil; Olson, Christopher G; Weinberg, Lori
2017-01-01
Objective To validate, in US community-based colposcopy clinics, previous reports of increased detection of high-grade cervical intraepithelial neoplasia (CIN2+) with biopsies selected using dynamic spectral imaging (DSI) mapping after standard colposcopy. Study design Cross-sectional observational study of 26 colposcopists across nine clinics recruiting consecutive colposcopy patients. Standard assessment with biopsy selections was completed before seeing the DSI map which was subsequently interpreted and used for additional biopsies per clinical judgment. Primary measure was the number of women with CIN2+ detected by DSI-assisted biopsies, over those detected by standard colposcopy biopsies. Results A total of 887 women were recruited. After exclusions, 881 women and 1,189 biopsies were analyzed. Standard biopsy detected 78 women with CIN2+ and DSI-assisted biopsies another 34, increasing the detection rate from 8.85% to 12.71% (p=0.00016). This was achieved with 16.16% of DSI-assisted biopsies finding CIN2+ compared to 13.24% for the preceding standard biopsies. For secondary specificity analysis, 431 women had only
A Review of Inflammatory Processes of the Breast with a Focus on Diagnosis in Core Biopsy Samples
D’Alfonso, Timothy M.; Ginter, Paula S.; Shin, Sandra J.
2015-01-01
Inflammatory and reactive lesions of the breast are relatively uncommon among benign breast lesions and can be the source of an abnormality on imaging. Such lesions can simulate a malignant process, based on both clinical and radiographic findings, and core biopsy is often performed to rule out malignancy. Furthermore, some inflammatory processes can mimic carcinoma or other malignancy microscopically, and vice versa. Diagnostic difficulty may arise due to the small and fragmented sample of a core biopsy. This review will focus on the pertinent clinical, radiographic, and histopathologic features of the more commonly encountered inflammatory lesions of the breast that can be characterized in a core biopsy sample. These include fat necrosis, mammary duct ectasia, granulomatous lobular mastitis, diabetic mastopathy, and abscess. The microscopic differential diagnoses for these lesions when seen in a core biopsy sample will be discussed. PMID:26095437
A Review of Inflammatory Processes of the Breast with a Focus on Diagnosis in Core Biopsy Samples.
D'Alfonso, Timothy M; Ginter, Paula S; Shin, Sandra J
2015-07-01
Inflammatory and reactive lesions of the breast are relatively uncommon among benign breast lesions and can be the source of an abnormality on imaging. Such lesions can simulate a malignant process, based on both clinical and radiographic findings, and core biopsy is often performed to rule out malignancy. Furthermore, some inflammatory processes can mimic carcinoma or other malignancy microscopically, and vice versa. Diagnostic difficulty may arise due to the small and fragmented sample of a core biopsy. This review will focus on the pertinent clinical, radiographic, and histopathologic features of the more commonly encountered inflammatory lesions of the breast that can be characterized in a core biopsy sample. These include fat necrosis, mammary duct ectasia, granulomatous lobular mastitis, diabetic mastopathy, and abscess. The microscopic differential diagnoses for these lesions when seen in a core biopsy sample will be discussed.
Gipponi, Marco; Fregatti, Piero; Garlaschi, Alessandro; Calabrese, Massimo; Baccini, Paola; Gallo, Maurizio; Murelli, Federica; Margarino, Cecilia; Bobbio, Carolina; Friedman, Daniele
2015-04-01
Fine-needle aspiration cytology (FNAC) is a simple and reliable technique to assess breast lesions, although a definitive differential diagnosis (benignity vs. cancer) is achieved approximately in 60-70% of cases because an inadequate (C1), atypical (C3) or suspicious (C4) category is otherwise reported. A retrospective analysis of 763 cases with C3 or C4 reports was performed to define their positive predictive value (PPV), as well as the practical implications of clinical and imaging findings as for clinical decision-making. FNACs were collected from January 2003 to September 2012 at the Breast Unit of IRCCS "A.O.U. San Martino-IST" Genoa, with each being received later to definitive histology. The PPV for cancer of C3/C4 categories were computed to measure the accuracy of FNAC; moreover, the PPV was also stratified according to clinical, mammography and sonography data alone or by their combination. The PPV of C3 and C4 was 21.1% (80/380) and 84.1 % (322/383), respectively. Within each C3/C4 category, a significant direct correlation (p<0.001) between the suspicion index of clinical, mammography and sonography data and cancer detection rate was always observed. The PPV of C3/C4 stratified by the combination of clinical and imaging findings showed satisfactory values in the C3 category only when there was an agreement between clinical and imaging findings, whereas the PPV of the C4 category was always remarkably high (ranging from 92.3% to 100%). the diagnostic work-up in C4 reports or in patients with a C3 report but with an high suspicion index at clinical or imaging examination should be preferably implemented by means of a core biopsy to optimize the therapeutic planning; given a C3 report with dubious clinical and/or imaging findings, an excisional biopsy (or in alternative vacuum-assisted breast biopsy with complete removal of the nodule) should be preferably performed in order to reach a definitive histological dia gnosis with no further delay. Copyright© 2015 International Institute of Anticancer Research (Dr. John G. Delinassios), All rights reserved.
Shikanov, Sergey A; Thong, Alan; Gofrit, Ofer N; Zagaja, Gregory P; Steinberg, Gary D; Shalhav, Arieh L; Zorn, Kevin C
2008-07-01
We sought to evaluate the pathologic results and postoperative outcomes for men undergoing robot-assisted laparoscopic radical prostatectomy (RLRP) for biopsy Gleason score (GS) 8 to 10 disease. Stratification of these patients according to preoperative variables was also performed in an attempt to predict organ-confined cancer. A prospective RLRP database identified all patients with preoperative biopsy GS 8 to 10. Variables, including prostate-specific antigen (PSA), percent positive biopsy cores (%PBC), maximal percentage of cancer in biopsy core (%MCB), clinical stage, pathologic stage, pathologic GS, surgical margins status, lymph node status, time to biochemical recurrence, and recurrence rate, were evaluated. Preoperative variables were treated as continuous and categorical using PSA, %PBC and %MCB cutoffs of 10 ng/mL, 50%, and 30%, respectively. Between February 2003 and September 2007, a total of 1225 RLRPs were performed at the University of Chicago Medical Center. Seventy-two (5.9%) patients had preoperative biopsy GS 8 to 10. Two patients received neoadjuvant hormonal therapy and were excluded. Among 70 patients evaluated, 33 (47%) had organconfined (pT(2)N0) disease. Forty (60.6%) patients had pathologic downgrading to GS
Ultrasound-guided core biopsy in the diagnosis of lymphoma of the head and neck. A 9 year experience
Burke, C; Thomas, R; Inglis, C; Baldwin, A; Ramesar, K; Grace, R; Howlett, D C
2011-01-01
Objectives This retrospective study aimed to evaluate the diagnostic utility of ultrasound-guided core biopsy (USCB) in lymphoma of the head and neck, in particular whether core biopsy can provide sufficient diagnostic information for definitive treatment. Methods All lymphomas diagnosed in the head and neck at Eastbourne General Hospital between January 2000 and June 2009 were identified. Radiology and pathology reports were reviewed and the diagnostic techniques recorded. The type of biopsy (fine needle aspiration, needle core, surgical excision biopsy) used to establish a diagnosis sufficient to allow treatment, i.e. the "index" diagnostic technique, was identified. Previous inconclusive or inadequate biopsies were noted. Pathology reports based on USCB were graded 0–3 according to diagnostic completeness and ability to provide treatment information. Results Of 691 overall cases of lymphoma diagnosed over the 9 year period, 171 different patients presented with lymphoma in the head and neck. Of these 171, 83 had USCB biopsy during diagnostic work up. 60 were regarded as grade 3 where a confident diagnosis of lymphoma was made. In seven patients, clinical management proceeded on the basis of a suggestive (grade 2) pathology report without surgical excision, and these were therefore also included as "index" biopsies. Overall therefore, 67/83 core biopsies (81%) provided adequate information to allow treatment. Surgical excision biopsy was the index modality in 104 cases. Conclusion In the majority of cases USCB is adequate for confident histopathological diagnosis avoiding the need for surgical excision biopsy in cases of suspected head and neck lymphoma. PMID:21427181
Wong, Lih-Ming; Toi, Ants; Van der Kwast, Theodorus; Trottier, Greg; Alibhai, Shabbir M H; Timilshina, Narhari; Evans, Andrew; Zlotta, Alexandre; Fleshner, Neil; Finelli, Antonio
2014-10-01
We investigated the frequency of cancer and pathological progression in transition zone biopsies in men undergoing multiple rebiopsies while on active surveillance. Eligibility criteria of the active surveillance prostate cancer database (1997 to 2012) at our tertiary center includes prostate specific antigen 10 ng/ml or less, cT2 or less, no Gleason grade 4 or 5, 3 or fewer positive cores, no core with greater than 50% involvement, patient age 75 years or less and 1 or more biopsies after initial diagnostic biopsy. We excluded from analysis men with fewer than 10 cores at diagnostic biopsy and/or confirmatory biopsy greater than 24 months after diagnostic biopsy. Multiparametric magnetic resonance imaging was performed selectively to investigate incongruity between prostate specific antigen and biopsy findings. Pathological progression was defined by grade and/or volume (greater than 50% of core involved). Transition zone progression was subdivided into exclusively transition zone and combined transition zone (transition and peripheral zones). A multivariate Cox proportional hazards model was used to determine predictors of transition zone progression. A total of 392 men were considered in analysis. Median followup was 45.5 months. At each biopsy during active surveillance (confirmatory biopsy to biopsy 5+) there were transition zone positive cores in 18.6% to 26.7% of cases, all transition zone progression in 5.9% to 11.1% and exclusively transition zone progression in 2.7% to 6.7%. Volume related progression was noted more frequently than grade related progression (24 vs 9 cases). Predictors of only transition zone progression were the maximum percent in a single core (HR 1.99, 95% CI 1.30-3.04, p = 0.002) and cancer on magnetic resonance imaging (HR 3.19, 95% CI 1.23-8.27, p = 0.02). Across multiple active surveillance biopsies 2.7% to 6.7% of men had only transition zone progression. We recommend that transition zone biopsy be considered in all men at confirmatory biopsy. Positive magnetic resonance imaging findings or a high percent of core involvement may subsequently be useful to identify patients at risk. Copyright © 2014 American Urological Association Education and Research, Inc. Published by Elsevier Inc. All rights reserved.
Microarray gene expression profiling using core biopsies of renal neoplasia.
Rogers, Craig G; Ditlev, Jonathon A; Tan, Min-Han; Sugimura, Jun; Qian, Chao-Nan; Cooper, Jeff; Lane, Brian; Jewett, Michael A; Kahnoski, Richard J; Kort, Eric J; Teh, Bin T
2009-01-01
We investigate the feasibility of using microarray gene expression profiling technology to analyze core biopsies of renal tumors for classification of tumor histology. Core biopsies were obtained ex-vivo from 7 renal tumors-comprised of four histological subtypes-following radical nephrectomy using 18-gauge biopsy needles. RNA was isolated from these samples and, in the case of biopsy samples, amplified by in vitro transcription. Microarray analysis was then used to quantify the mRNA expression patterns in these samples relative to non-diseased renal tissue mRNA. Genes with significant variation across all non-biopsy tumor samples were identified, and the relationship between tumor and biopsy samples in terms of expression levels of these genes was then quantified in terms of Euclidean distance, and visualized by complete linkage clustering. Final pathologic assessment of kidney tumors demonstrated clear cell renal cell carcinoma (4), oncocytoma (1), angiomyolipoma (1) and adrenalcortical carcinoma (1). Five of the seven biopsy samples were most similar in terms of gene expression to the resected tumors from which they were derived in terms of Euclidean distance. All seven biopsies were assigned to the correct histological class by hierarchical clustering. We demonstrate the feasibility of gene expression profiling of core biopsies of renal tumors to classify tumor histology.
Microarray gene expression profiling using core biopsies of renal neoplasia
Rogers, Craig G.; Ditlev, Jonathon A.; Tan, Min-Han; Sugimura, Jun; Qian, Chao-Nan; Cooper, Jeff; Lane, Brian; Jewett, Michael A.; Kahnoski, Richard J.; Kort, Eric J.; Teh, Bin T.
2009-01-01
We investigate the feasibility of using microarray gene expression profiling technology to analyze core biopsies of renal tumors for classification of tumor histology. Core biopsies were obtained ex-vivo from 7 renal tumors—comprised of four histological subtypes—following radical nephrectomy using 18-gauge biopsy needles. RNA was isolated from these samples and, in the case of biopsy samples, amplified by in vitro transcription. Microarray analysis was then used to quantify the mRNA expression patterns in these samples relative to non-diseased renal tissue mRNA. Genes with significant variation across all non-biopsy tumor samples were identified, and the relationship between tumor and biopsy samples in terms of expression levels of these genes was then quantified in terms of Euclidean distance, and visualized by complete linkage clustering. Final pathologic assessment of kidney tumors demonstrated clear cell renal cell carcinoma (4), oncocytoma (1), angiomyolipoma (1) and adrenalcortical carcinoma (1). Five of the seven biopsy samples were most similar in terms of gene expression to the resected tumors from which they were derived in terms of Euclidean distance. All seven biopsies were assigned to the correct histological class by hierarchical clustering. We demonstrate the feasibility of gene expression profiling of core biopsies of renal tumors to classify tumor histology. PMID:19966938
Dobbs, Jessica; Krishnamurthy, Savitri; Kyrish, Matthew; Benveniste, Ana Paula; Yang, Wei; Richards-Kortum, Rebecca
2015-01-01
Tissue sampling is a problematic issue for inflammatory breast carcinoma, and immediate evaluation following core needle biopsy is needed to evaluate specimen adequacy. We sought to determine if confocal fluorescence microscopy provides sufficient resolution to evaluate specimen adequacy by comparing invasive tumor cellularity estimated from standard histologic images to invasive tumor cellularity estimated from confocal images of breast core needle biopsy specimens. Grayscale confocal fluorescence images of breast core needle biopsy specimens were acquired following proflavine application. A breast-dedicated pathologist evaluated invasive tumor cellularity in histologic images with hematoxylin and eosin staining and in grayscale and false-colored confocal images of cores. Agreement between cellularity estimates was quantified using a kappa coefficient. 23 cores from 23 patients with suspected inflammatory breast carcinoma were imaged. Confocal images were acquired in an average of less than 2 min per core. Invasive tumor cellularity estimated from histologic and grayscale confocal images showed moderate agreement by kappa coefficient: κ = 0.48 ± 0.09 (p < 0.001). Grayscale confocal images require less than 2 min for acquisition and allow for evaluation of invasive tumor cellularity in breast core needle biopsy specimens with moderate agreement to histologic images. We show that confocal fluorescence microscopy can be performed immediately following specimen acquisition and could indicate the need for additional biopsies at the initial visit.
Quentin, Michael; Blondin, Dirk; Arsov, Christian; Schimmöller, Lars; Hiester, Andreas; Godehardt, Erhard; Albers, Peter; Antoch, Gerald; Rabenalt, Robert
2014-11-01
Magnetic resonance imaging guided biopsy is increasingly performed to diagnose prostate cancer. However, there is a lack of well controlled, prospective trials to support this treatment method. We prospectively compared magnetic resonance imaging guided in-bore biopsy with standard systematic transrectal ultrasound guided biopsy in biopsy naïve men with increased prostate specific antigen. We performed a prospective study in 132 biopsy naïve men with increased prostate specific antigen (greater than 4 ng/ml). After 3 Tesla functional multiparametric magnetic resonance imaging patients were referred for magnetic resonance imaging guided in-bore biopsy of prostate lesions (maximum 3) followed by standard systematic transrectal ultrasound guided biopsy (12 cores). We analyzed the detection rates of prostate cancer and significant prostate cancer (greater than 5 mm total cancer length or any Gleason pattern greater than 3). A total of 128 patients with a mean ± SD age of 66.1 ± 8.1 years met all study requirements. Median prostate specific antigen was 6.7 ng/ml (IQR 5.1-9.0). Transrectal ultrasound and magnetic resonance imaging guided biopsies provided the same 53.1% detection rate, including 79.4% and 85.3%, respectively, for significant prostate cancer. Magnetic resonance imaging and transrectal ultrasound guided biopsies missed 7.8% and 9.4% of clinically significant prostate cancers, respectively. Magnetic resonance imaging biopsy required significantly fewer cores and revealed a higher percent of cancer involvement per biopsy core (each p <0.01). Combining the 2 methods provided a 60.9% detection rate with an 82.1% rate for significant prostate cancer. Magnetic resonance imaging guided in-bore and systematic transrectal ultrasound guided biopsies achieved equally high detection rates in biopsy naïve patients with increased prostate specific antigen. Magnetic resonance imaging guided in-bore biopsies required significantly fewer cores and revealed a significantly higher percent of cancer involvement per biopsy core. Copyright © 2014 American Urological Association Education and Research, Inc. Published by Elsevier Inc. All rights reserved.
Management of hidradenitis suppurativa wounds with an internal vacuum-assisted closure device.
Chen, Y Erin; Gerstle, Theodore; Verma, Kapil; Treiser, Matthew D; Kimball, Alexandra B; Orgill, Dennis P
2014-03-01
Hidradenitis suppurativa is a chronic, debilitating disease that is difficult to treat. Once medical management fails, wide local excision offers the best chance for cure. However, the resultant wound often proves too large or contaminated for immediate closure. The authors performed a retrospective chart review of hidradenitis cases managed surgically between 2005 and 2010. Data collected included patient characteristics, management method, and outcomes. Approximately half of the patients received internal vacuum-assisted closure therapy using the vacuum-assisted closure system and delayed closure and half of the patients received immediate primary closure at the time of their excision. Delayed closure consisted of closing the majority of the wound in a linear fashion following internal vacuum-assisted closure while accepting healing by means of secondary intention for small wound areas. Patients managed with internal vacuum-assisted closure had wounds on average four times larger in area than patients managed without internal vacuum-assisted closure. In both groups, all wounds were eventually closed primarily. Healing times averaged 2.2 months with internal vacuum-assisted closure and 2.7 months without. At an average follow-up time of 2.3 months, all patients with internal vacuum-assisted closure had no recurrence of their local disease. Severe hidradenitis presents a treatment challenge, as surgical excisions are often complicated by difficult closures and unsatisfactory recurrence rates. This study demonstrates that wide local excision with reasonable outcomes can be achieved using accelerated delayed primary closure. This method uses internal vacuum-assisted closure as a bridge between excision and delayed primary closure, facilitating closure without recurrence in large, heavily contaminated wounds. Therapeutic, III.
Development and Evaluation of Stitched Sandwich Panels
NASA Technical Reports Server (NTRS)
Stanley, Larry E.; Adams, Daniel O.; Reeder, James R. (Technical Monitor)
2001-01-01
This study explored the feasibility and potential benefits provided by the addition of through-the-thickness reinforcement to sandwich structures. Through-the-thickness stitching is proposed to increase the interlaminar strength and damage tolerance of composite sandwich structures. A low-cost, out-of-autoclave processing method was developed to produce composite sandwich panels with carbon fiber face sheets, a closed-cell foam core, and through-the-thickness Kevlar stitching. The sandwich panels were stitched in a dry preform state, vacuum bagged, and infiltrated using Vacuum Assisted Resin Transfer Molding (VARTM) processing. For comparison purposes, unstitched sandwich panels were produced using the same materials and manufacturing methodology. Test panels were produced initially at the University of Utah and later at NASA Langley Research Center. Four types of mechanical tests were performed: flexural testing, flatwise tensile testing, core shear testing, and edgewise compression testing. Drop-weight impact testing followed by specimen sectioning was performed to characterize the damage resistance of stitched sandwich panels. Compression after impact (CAI) testing was performed to evaluate the damage tolerance of the sandwich panels. Results show significant increases in the flexural stiffness and strength, out-of-plane tensile strength, core shear strength, edgewise compression strength, and compression-after-impact strength of stitched sandwich structures.
Vacuum-assisted venous return reduces blood usage.
Banbury, Michael K; White, Jennifer A; Blackstone, Eugene H; Cosgrove, Delos M
2003-09-01
To determine whether vacuum-assisted venous return has clinical advantages over conventional gravity drainage apart from allowing the use of smaller cannulas and shorter tubing. A total of 150 valve operations were performed at our institution between February and July 1999 using vacuum-assisted venous return with small venous cannulas connected to short tubing. These were compared with (1) 83 valve operations performed between April 1997 and January 1998 using the initial version of vacuum-assisted venous return, and (2) 124 valve operations performed between January and April of 1997 using conventional gravity drainage. Priming volume, hematocrit value, red blood cell usage, and total blood product usage were compared multivariably. These comparisons were covariate and propensity adjusted for dissimilarities between the groups and confirmed by propensity-matched pairs analysis. Priming volume was 1.4 +/- 0.4 L for small-cannula vacuum-assisted venous return, 1.7 +/- 0.4 L for initial vacuum-assisted venous return, and 2.0 +/- 0.4 L for gravity drainage (P <.0001). Smaller priming resulted in higher hematocrit values both at the beginning of cardiopulmonary bypass (27% +/- 5% compared with 26% +/- 4% and 25% +/- 4%, respectively, P <.0001) and at the end (30% +/- 4% compared with 28% +/- 4% and 27% +/- 4%, respectively, P <.0001). Red cell transfusions were used in 17% of the patients having small-cannula vacuum-assisted venous return, 27% of the initial patients having vacuum-assisted venous return, and 37% of the patients having gravity drainage (P =.001); total blood product usage was 19%, 27%, and 39%, respectively (P =.002). Although ministernotomy also was associated with reduced blood product usage (P <.004), propensity matching on type of sternotomy confirmed the association of vacuum-assisted venous return with lowered blood product usage. Vacuum-assisted venous return results in (1) higher hematocrit values during cardiopulmonary bypass and (2) decreased red cell and total blood product usage.
Breast 3 T-MR imaging: indication for stereotactic vacuum-assisted breast biopsy.
Yamamoto, Nobuko; Yoshizako, Takeshi; Yoshikawa, Kazuaki; Itakura, Masayuki; Maruyama, Riruke; Kitagaki, Hajime
2014-01-01
The purpose of this study was to assess indications for stereotactic vacuum-assisted breast biopsy (SVAB) evaluated by breast 3 T-magnetic resonance (3 T-MR) imaging in patients showing suspicious microcalcifications on mammography and negative ultrasound (US) findings. Fifty-five patients with 55 breast lesions showing suspicious microcalcifications on mammography and negative US findings underwent preoperative 3 T-MR examination including dynamic MR imaging. All patients underwent SVAB within 1 month of MR imaging. The pathological diagnosis of each breast lesion was made by examining tissues obtained by SVAB or radical/partial mastectomy. 3 T-MR imaging findings were evaluated by using the American College of Radiology Breast Imaging Reporting and Data System Atlas (BI-RADS-MRI) and then were correlated with the histopathological findings. When BI-RADS 4 and 5 MR imaging lesions were assumed to be malignant, the usefulness of 3 T-MR imaging was evaluated for diagnosis of impalpable breast lesions by SVAB among lesions with microcalcification detected by mammography and negative US findings. There were 21 malignant lesions, including 5 invasive ductal carcinomas, 16 lesions of ductal carcinoma in situ (DCIS). The sensitivity, specificity, positive predictive value, negative predictive value, and accuracy of 3 T-MR imaging for deciding the indications for SVAB was 90.5%, 97.1%, 95.0%, 94.3%, and 94.5%, respectively. The one-false negative case was a DCIS with small enhancing lesions (0.5 mm). The one false-positive case was ductal adenoma with a linear ductal pattern of enhancement. 3 T-MR imaging may be useful for deciding the indications for SVAB in patients who have breast lesions with microcalcification that are impalpable and are detected by mammography and negative US findings. However, our findings should be considered preliminary and further prospective investigation is required.
Stoler, Daniel L; Stewart, Carleton C; Stomper, Paul C
2002-02-01
Molecular studies of breast lesions have been constrained by difficulties in procuring adequate tissues for analyses. Standard procedures are restricted to larger, palpable masses or the use of paraffin-embedded materials, precluding facile procurement of fresh specimens of early lesions. We describe a study to determine the yield and characteristics of sorted cell populations retrieved in core needle biopsy specimen rinses from a spectrum of breast lesions. Cells from 114 consecutive stereotactic core biopsies of mammographic lesions released into saline washes were submitted for flow cytometric analysis. For each specimen, epithelial cells were separated from stromal and blood tissue based on the presence of cytokeratin 8 and 18 markers. Epithelial cell yields based on pathological diagnoses of the biopsy specimen, patient age, and mammographic appearance of the lesion were determined. Biopsies containing malignant lesions yielded significantly higher numbers of cells than were obtained from benign lesion biopsies. Significantly greater cell counts were observed from lesions from women age 50 or above compared with those of younger women. Mammographic density surrounding the biopsy site, the mammographic appearance of the lesion, and the number of cores taken at the time of biopsy appeared to have little effect on the yield of epithelial cells. We demonstrate the use of flow cytometric sorting of stereotactic core needle biopsy washes from lesions spanning the spectrum of breast pathology to obtain epithelial cells in sufficient numbers to meet the requirements of a variety of molecular and genetic analyses.
Evolving biopsy techniques for the diagnosis of neuroblastoma in children.
Campagna, Giovanni; Rosenfeld, Eric; Foster, Jennifer; Vasudevan, Sanjeev; Nuchtern, Jed; Kim, Eugene; Commander, Sarah; Naik-Mathuria, Bindi
2018-04-14
To compare the adequacy and safety of percutaneous core needle biopsy and surgical wedge biopsy of neuroblastoma in children. A retrospective review of patients who underwent biopsy for intermediate- or high-risk neuroblastoma at our institution between 2011 and 2015 was performed (recent cohort). Procedure details and outcomes were collected and analyzed using descriptive statistics and Wilcoxon rank tests; P < 0.05 was considered significant. Published data from 2002 to 2010 were compared (historic cohort). Since 2011, percutaneous, ultrasound-guided, core needle biopsy has been more commonly utilized (47% (16/34) recent vs. 25% (7/28) historic; P = 0.07), and the number of core needle samples increased from median 7 (historic) to 25 (recent). Complications decreased (21% (7/34) recent vs. 64% (18/28) historic; P < 0.01). Biopsy adequacy in the recent cohort was similar (94% percutaneous vs. 89% surgical; P = 1.00), which is improved from the historic cohort (71% percutaneous vs. 100% surgical; P = 0.06). Larger tumors were more likely to have a percutaneous biopsy (82 ± 37 cm percutaneous vs. 47 ± 29 cm surgical; P = 0.04). When multiple cores are obtained, percutaneous core needle biopsy is adequate for complete tissue diagnosis of neuroblastoma and can be safely performed. This can be considered as an alternative to open surgical biopsy. Treatment Study. III. Copyright © 2018 Elsevier Inc. All rights reserved.
Noël, Jean-Christophe; Buxant, Frédéric; Engohan-Aloghe, Corinne
2010-12-01
The entity of pure flat epithelial atypia remains a challenge due to controversy of the surgical management of residual microcalcifications after core needle biopsies. This study aims to assess the morphological data observed in immediate surgical resection specimen of residual microcalcifications after a diagnosis of pure flat epithelial atypia on mammotome core biopsy. Sixty-two mammotome core biopsy with a diagnosis of pure flat epithelial atypia (flat epithelial atypia without associated atypical ductal hyperplasia, in situ and/or invasive carcinoma) were identified. From these 62 cases, 20 presented residual microcalcifications and underwent an immediate surgical excision after mammotome. Of the 20 patients with excised microcalcifications, 8 (40%)cases had residual pure flat epithelial atypia, 4 (20%) cases had atypical ductal hyperplasia, 4 (20%) cases had lobular in situ neoplasia, no lesions were retrieved in 4 (20%) case. None of the patients had either in situ ductal carcinoma and/or invasive carcinoma. Surgical resection of residual microcalcifications after the diagnosis of pure flat epithelial atypia on core needle biopsy remains still a debate. The present study shows no cases of in situ ductal and/or invasive carcinoma on immediate excision of residual microcalcifications after mammotome core biopsies. Copyright © 2009 Elsevier Ltd. All rights reserved.
Subsequent Breast Cancer Risk Following Diagnosis of Atypical Ductal Hyperplasia on Needle Biopsy.
Menes, Tehillah S; Kerlikowske, Karla; Lange, Jane; Jaffer, Shabnam; Rosenberg, Robert; Miglioretti, Diana L
2017-01-01
Atypical ductal hyperplasia (ADH) is a known risk factor for breast cancer. Published risk estimates are based on cohorts that included women whose ADH was diagnosed before widespread use of screening mammograms and did not differentiate between the methods used to diagnose ADH, which may be related to the size of the ADH focus. These risks may overestimate the risk in women with presently diagnosed ADH. To examine the risk of invasive cancer associated with ADH diagnosed using core needle biopsy vs excisional biopsy. A cohort study was conducted comparing the 10-year cumulative risk of invasive breast cancer in 955 331 women undergoing mammography with and without a diagnosis of ADH. Data were obtained from 5 breast imaging registries that participate in the National Cancer Institute-funded Breast Cancer Surveillance Consortium. Diagnosis of ADH on core needle biopsy or excisional biopsy in women undergoing mammography. Ten-year cumulative risk of invasive breast cancer. The sample included 955 331 women with 1727 diagnoses of ADH, 1058 (61.3%) of which were diagnosed by core biopsy and 635 (36.8%) by excisional biopsy. The mean (interquartile range) age of the women at diagnosis was 52.6 (46.9-60.4) years. From 1996 to 2012, the proportion of ADH diagnosed by core needle biopsy increased from 21% to 77%. Ten years following a diagnosis of ADH, the cumulative risk of invasive breast cancer was 2.6 (95% CI, 2.0-3.4) times higher than the risk in women with no ADH. Atypical ductal hyperplasia diagnosed via excisional biopsy was associated with an adjusted hazard ratio (HR) of 3.0 (95% CI, 2-4.5) and, via core needle biopsy, with an adjusted HR of 2.2 (95% CI, 1.5-3.4). Ten years after an ADH diagnosis, an estimated 5.7% (95% CI, 4.3%-10.1%) of the women had a diagnosis of invasive cancer. Women with ADH diagnosed on excisional biopsy had a slightly higher risk (6.7%; 95% CI, 3.0%-12.8%) compared with those with ADH diagnosed via core needle biopsy (5%; 95% CI, 2.2%-8.9%). Current 10-year risks of invasive breast cancer after a diagnosis of ADH may be lower than those previously reported. The risk associated with ADH is slightly lower for women whose ADH was diagnosed by needle core biopsy compared with excisional biopsy.
Mammotome-Assisted Liposuction: A Novel Technique for Accessory Breasts.
Tang, Xin
2017-06-01
Due to its minimally invasive and highly precise nature, the mammotome, a vacuum-assisted breast biopsy device, has proven effective for the treatment of benign breast lesions. Taking advantage of both liposuction and the mammotome, we utilized the mammotome device for the excision of accessory breasts. Between July 2010 and June 2014, 16 patients with accessory breasts received mammotome-assisted liposuction. After adipose was removed using this procedure, the mammotome system was used to excise the fibro-glandular tissue in accessory breasts under ultrasound monitoring. All patients were satisfied with their appearance after surgery. A single 5-mm incision, which was well hidden in the axillary skin folds and allowed for restoration, provided an aesthetically pleasing contour to the axilla. Mammotome-assisted liposuction is a new approach that can be used to excise both adipose and fibro-glandular breast tissue simultaneously with a minimal incision, and provides a favorable contour to the axilla. This journal requires that authors assign a level of evidence to each article. For a full description of these Evidence-Based Medicine ratings, please refer to the Table of Contents or the online Instructions to Authors www.springer.com/00266 .
DeWitt, John; Cho, Chang-Min; Lin, Jingmei; Al-Haddad, Mohammad; Canto, Marcia Irene; Salamone, Ashley; Hruban, Ralph H.; Messallam, Ahmed A.; Khashab, Mouen A.
2015-01-01
Background and study aims: The optimal core biopsy needle for endoscopic ultrasound (EUS) is unknown. The principle aim of this study is to compare outcomes of EUS-fine-needle biopsy (EUS-FNB) with a new 19-gauge EUS histology needle (ProCore, Cook Medical Inc., Winston-Salem, North Carolina, United States) to a conventional 19-gauge Tru-Cut biopsy (EUS-TCB) needle (19G, Quick-Core, Cook Medical Inc.). Patients and methods: Patients referred for EUS who require possible histologic biopsy were prospectively randomized to EUS-FNB or EUS-TCB. With the initial needle, ≤ 3 biopsies were obtained until either technical failure or an adequate core was obtained. Patients with suspected inadequate biopsies were crossed over to the other needle and similarly ≤ 3 passes were obtained until adequate cores or technical failure occurred. Technical success, diagnostic histology, accuracy and complication rates were evaluated. Results: Eighty-five patients (mean 58 years; 43 male) were randomized to FNB (n = 44) and TCB (n = 41) with seven patients excluded. Procedure indication, biopsy site, mass size, number of passes, puncture site, overall technical success and adverse events were similar between the two groups. FNB specimens had a higher prevalence of diagnostic histology (85 % vs. 57 %; P = 0.006), accuracy (88 % vs. 62 %; P = 0.02), mean total length (19.4 vs. 4.3 mm; P = 0.001), mean complete portal triads from liver biopsies (10.4 vs. 1.3; P = 0.0004) and required fewer crossover biopsies compared to those of TCB (2 % vs. 65 %; P = 0.0001). Overall technical success and complication rates were comparable. Conclusion: EUS-FNB using a 19-gauge FNB needle is superior to 19-gauge EUS-TCB needle. PMID:26528504
Biggar, Magdalena A; Kerr, Kris M; Erzetich, Lisa M; Bennett, Ian C
2012-01-01
Columnar cell change with atypia (CCCA) is a relatively recently recognized pathologic breast entity considered to be a risk factor for subsequent development of breast carcinoma. The aim of this study was to investigate the significance of finding CCCA on breast core biopsy, by establishing the frequency of other breast pathology on subsequently performed surgical excision specimens. All cases with CCCA as the most advanced lesion on core biopsy were reviewed. After excision, another advanced proliferative lesion was identified in 17 (33%) patients, including three patients (6%) with in situ or invasive carcinoma. An additional five patients (10%) were concurrently diagnosed with primary breast carcinoma at other sites. These findings indicate that when CCCA is found on core biopsy, open surgical biopsy of the relevant area should be performed and that workup of both breasts should be undertaken to exclude coexistent breast carcinoma at alternative sites. © 2012 Wiley Periodicals, Inc.
Iftimia, Nicusor; Park, Jesung; Maguluri, Gopi; Krishnamurthy, Savitri; McWatters, Amanda; Sabir, Sharjeel H
2018-02-01
We report the development and the pre-clinical testing of a new technology based on optical coherence tomography (OCT) for investigating tissue composition at the tip of the core biopsy needle. While ultrasound, computed tomography, and magnetic resonance imaging are routinely used to guide needle placement within a tumor, they still do not provide the resolution needed to investigate tissue cellularity (ratio between viable tumor and benign stroma) at the needle tip prior to taking a biopsy core. High resolution OCT imaging, however, can be used to investigate tissue morphology at the micron scale, and thus to determine if the biopsy core would likely have the expected composition. Therefore, we implemented this capability within a custom-made biopsy gun and evaluated its capability for a correct estimation of tumor tissue cellularity. A pilot study on a rabbit model of soft tissue cancer has shown the capability of this technique to provide correct evaluation of tumor tissue cellularity in over 85% of the cases. These initial results indicate the potential benefit of the OCT-based approach for improving the success of the core biopsy procedures.
Determining the Optimal Number of Core Needle Biopsy Passes for Molecular Diagnostics.
Hoang, Nam S; Ge, Benjamin H; Pan, Lorraine Y; Ozawa, Michael G; Kong, Christina S; Louie, John D; Shah, Rajesh P
2018-03-01
The number of core biopsy passes required for adequate next-generation sequencing is impacted by needle cut, needle gauge, and the type of tissue involved. This study evaluates diagnostic adequacy of core needle lung biopsies based on number of passes and provides guidelines for other tissues based on simulated biopsies in ex vivo porcine organ tissues. The rate of diagnostic adequacy for pathology and molecular testing from lung biopsy procedures was measured for eight operators pre-implementation (September 2012-October 2013) and post-implementation (December 2013-April 2014) of a standard protocol using 20-gauge side-cut needles for ten core biopsy passes at a single academic hospital. Biopsy pass volume was then estimated in ex vivo porcine muscle, liver, and kidney using side-cut devices at 16, 18, and 20 gauge and end-cut devices at 16 and 18 gauge to estimate minimum number of passes required for adequate molecular testing. Molecular diagnostic adequacy increased from 69% (pre-implementation period) to 92% (post-implementation period) (p < 0.001) for lung biopsies. In porcine models, both 16-gauge end-cut and side-cut devices require one pass to reach the validated volume threshold to ensure 99% adequacy for molecular characterization, while 18- and 20-gauge devices require 2-5 passes depending on needle cut and tissue type. Use of 20-gauge side-cut core biopsy needles requires a significant number of passes to ensure diagnostic adequacy for molecular testing across all tissue types. To ensure diagnostic adequacy for molecular testing, 16- and 18-gauge needles require markedly fewer passes.
[Explorations of breast microcalcifications: Guidelines].
Chamming's, F; Chopier, J; Mathelin, C; Chéreau, E
2015-12-01
To assess imaging performances for the detection, characterization and biopsy of breast microcalcifications and make recommendations. French and English publications were searched using PubMed, Cochrane Library and international learned societies recommendations. Digital mammography (DR [Direct Radiography] and CR [Computed Radiography]) and screen-film mammography demonstrate good performances for the detection and the characterization of breast microcalcifications. Systematic use of the 2013 edition of the BI-RADS lexicon is recommended for description and characterization of microcalcifications. Faced with BI-RADS 4 or 5 microcalcifications, breast ultrasound is recommended but a normal result does not eliminate the diagnosis of cancer and other examination should be performed. Literature review does not allow recommending digital breast tomosynthesis, elastography or MRI to analyze microcalcifications. In case of probably benign microcalcifications (BI-RADS 3), six months, one year and at least two years follow-up are recommended. In case a biopsy is indicated, it is recommended to use a vacuum-assisted macrobiopsy system with 11-gauges needles or bigger. If no calcification is visible on the radiography of the specimen, it is recommended to obtain additional samples. Copyright © 2015 Elsevier Masson SAS. All rights reserved.
Woo, Sungmin; Kim, Sang Youn; Lee, Joongyub; Kim, Seung Hyup; Cho, Jeong Yeon
2016-10-01
To evaluate PI-RADSv2 for predicting pathological downgrading after radical prostatectomy (RP) in patients with biopsy-proven Gleason score (GS) 7(3+4) PC. A total of 105 patients with biopsy-proven GS 7(3+4) PC who underwent multiparametric prostate MRI followed by RP were included. Two radiologists assigned PI-RADSv2 scores for each patient. Preoperative clinicopathological variables and PI-RADSv2 scores were compared between patients with and without downgrading after RP using the Wilcoxon rank sum test or Fisher's exact test. Logistic regression analyses with Firth's bias correction were performed to assess their association with downgrading. Pathological downgrading was identified in ten (9.5 %) patients. Prostate-specific antigen (PSA), PSA density, percentage of cores with GS 7(3+4), and greatest percentage of core length (GPCL) with GS 7(3+4) were significantly lower in patients with downgrading (p = 0.002-0.037). There was no significant difference in age and clinical stage (p = 0.537-0.755). PI-RADSv2 scores were significantly lower in patients with downgrading (3.8 versus 4.4, p = 0.012). At univariate logistic regression analysis, PSA, PSA density, and PI-RADSv2 scores were significant predictors of downgrading (p = 0.003-0.022). Multivariate analysis revealed only PSA density and PI-RADSv2 scores as independent predictors of downgrading (p = 0.014-0.042). The PI-RADSv2 scoring system was an independent predictor of pathological downgrading after RP in patients with biopsy-proven GS 7(3+4) PC. • PI-RADSv2 was an independent predictor of downgrading in biopsy-proven GS 7(3+4) PC • PSA density was also an independent predictor of downgrading • MRI may assist in identifying AS candidates in biopsy-proven GS 7(3+4) PC patients.
Accessible or Inaccessible? Diagnostic Efficacy of CT-Guided Core Biopsies of Head and Neck Masses
DOE Office of Scientific and Technical Information (OSTI.GOV)
Cunningham, Jane D., E-mail: janecunningham0708@gmail.com; McCusker, Mark W.; Power, Sarah
PurposeTissue sampling of lesions in the head and neck is challenging due to complex regional anatomy and sometimes necessitates open surgical biopsy. However, many patients are poor surgical candidates due to comorbidity. Thus, we evaluated the use of CT guidance for establishing histopathological diagnosis of head and neck masses.MethodsAll consecutive patients (n = 22) who underwent CT-guided core biopsy of head or neck masses between April 2009 and August 2012 were retrospectively reviewed using the departmental CT interventional procedures database. The indication for each biopsy performed was to establish or exclude a diagnosis of neoplasia in patients with suspicious head or neckmore » lesions found on clinical examination or imaging studies. Patients received conscious sedation and 18 G, semiautomated core needle biopsies were performed by experienced neuroradiologists using 16-slice multidetector row CT imaging guidance (Somatom Definition Siemens Medical Solutions, Germany). Histopathology results of each biopsy were analysed.ResultsSixteen of 22 biopsies that were performed (73 %) yielded a pathological diagnosis. Anatomic locations biopsied included: masticator (n = 7), parapharyngeal (n = 3), parotid (n = 3), carotid (n = 3), perivertebral (n = 3), pharyngeal (n = 2), and retropharyngeal (n = 1) spaces. Six biopsies (27 %) were nondiagnostic due to inadequate tissue sampling, particularly small biopsy sample size and failure to biopsy the true sampling site due to extensive necrosis. No major complications were encountered.ConclusionsThe use of CT guidance to perform core biopsies of head and neck masses is an effective means of establishing histopathological diagnosis and reduces the need for diagnostic open surgical biopsy and general anaesthesia.« less
Turkbey, Baris; Xu, Sheng; Kruecker, Jochen; Locklin, Julia; Pang, Yuxi; Shah, Vijay; Bernardo, Marcelino; Baccala, Angelo; Rastinehad, Ardeshir; Benjamin, Compton; Merino, Maria J; Wood, Bradford J; Choyke, Peter L; Pinto, Peter A
2011-03-29
During transrectal ultrasound (TRUS)-guided prostate biopsies, the actual location of the biopsy site is rarely documented. Here, we demonstrate the capability of TRUS-magnetic resonance imaging (MRI) image fusion to document the biopsy site and correlate biopsy results with multi-parametric MRI findings. Fifty consecutive patients (median age 61 years) with a median prostate-specific antigen (PSA) level of 5.8 ng/ml underwent 12-core TRUS-guided biopsy of the prostate. Pre-procedural T2-weighted magnetic resonance images were fused to TRUS. A disposable needle guide with miniature tracking sensors was attached to the TRUS probe to enable fusion with MRI. Real-time TRUS images during biopsy and the corresponding tracking information were recorded. Each biopsy site was superimposed onto the MRI. Each biopsy site was classified as positive or negative for cancer based on the results of each MRI sequence. Sensitivity, specificity, and receiver operating curve (ROC) area under the curve (AUC) values were calculated for multi-parametric MRI. Gleason scores for each multi-parametric MRI pattern were also evaluated. Six hundred and 5 systemic biopsy cores were analyzed in 50 patients, of whom 20 patients had 56 positive cores. MRI identified 34 of 56 positive cores. Overall, sensitivity, specificity, and ROC area values for multi-parametric MRI were 0.607, 0.727, 0.667, respectively. TRUS-MRI fusion after biopsy can be used to document the location of each biopsy site, which can then be correlated with MRI findings. Based on correlation with tracked biopsies, T2-weighted MRI and apparent diffusion coefficient maps derived from diffusion-weighted MRI are the most sensitive sequences, whereas the addition of delayed contrast enhancement MRI and three-dimensional magnetic resonance spectroscopy demonstrated higher specificity consistent with results obtained using radical prostatectomy specimens.
van der Aa, Anouk A M A; Mannaerts, Christophe K; van der Linden, Hans; Gayet, Maudy; Schrier, Bart Ph; Mischi, Massimo; Beerlage, Harrie P; Wijkstra, Hessel
2018-02-01
To determine the value of a three-dimensional (3D) greyscale transrectal ultrasound (TRUS)-guided prostate biopsy system and biopsy core pre-embedding method on concordance between Gleason scores of needle biopsies and radical prostatectomy (RP) specimens. Retrospective analysis of prostate biopsies and subsequent RP for PCa in the Jeroen Bosch Hospital, the Netherlands, from 2007 to 2016. Two cohorts were analysed: conventional 2D TRUS-guided biopsies and RP (2007-2013, n = 266) versus 3D TRUS-guided biopsies with pre-embedding (2013-2016, n = 129). The impact of 3D TRUS-guidance with pre-embedding on Gleason score (GS) concordance between biopsy and RP was evaluated using the κ-coefficient. Predictors of biopsy GS 6 upgrading were assessed using logistic regression models. Gleason concordance was comparable between the two cohorts with a κ = 0.44 for the 3D cohort, compared to κ = 0.42 for the 2D cohort. 3D TRUS-guidance with pre-embedding, did not significantly affect the risk of biopsy GS 6 upgrading in univariate and multivariate analysis. 3D TRUS-guidance with biopsy core pre-embedding did not improve Gleason concordance. Improved detection techniques are needed for recognition of low-grade disease upgrading.
Kriegsmann, Mark; Casadonte, Rita; Kriegsmann, Jörg; Dienemann, Hendrik; Schirmacher, Peter; Hendrik Kobarg, Jan; Schwamborn, Kristina; Stenzinger, Albrecht; Warth, Arne; Weichert, Wilko
2016-01-01
Histopathological subtyping of non-small cell lung cancer (NSCLC) into adenocarcinoma (ADC), and squamous cell carcinoma (SqCC) is of utmost relevance for treatment stratification. However, current immunohistochemistry (IHC) based typing approaches on biopsies are imperfect, therefore novel analytical methods for reliable subtyping are needed. We analyzed formalin-fixed paraffin-embedded tissue cores of NSCLC by Matrix-assisted laser desorption/ionization (MALDI) imaging on tissue microarrays to identify and validate discriminating MALDI imaging profiles for NSCLC subtyping. 110 ADC and 98 SqCC were used to train a Linear Discriminant Analysis (LDA) model. Results were validated on a separate set of 58 ADC and 60 SqCC. Selected differentially expressed proteins were identified by tandem mass spectrometry and validated by IHC. The LDA classification model incorporated 339 m/z values. In the validation cohort, in 117 cases (99.1%) MALDI classification on tissue cores was in accordance with the pathological diagnosis made on resection specimen. Overall, three cases in the combined cohorts were discordant, after reevaluation two were initially misclassified by pathology whereas one was classified incorrectly by MALDI. Identification of differentially expressed peptides detected well-known IHC discriminators (CK5, CK7), but also less well known differentially expressed proteins (CK15, HSP27). In conclusion, MALDI imaging on NSCLC tissue cores as small biopsy equivalents is capable to discriminate lung ADC and SqCC with a very high accuracy. In addition, replacing multislide IHC by an one-slide MALDI approach may also save tissue for subsequent predictive molecular testing. We therefore advocate to pursue routine diagnostic implementation strategies for MALDI imaging in solid tumor typing. PMID:27473201
Kriegsmann, Mark; Casadonte, Rita; Kriegsmann, Jörg; Dienemann, Hendrik; Schirmacher, Peter; Hendrik Kobarg, Jan; Schwamborn, Kristina; Stenzinger, Albrecht; Warth, Arne; Weichert, Wilko
2016-10-01
Histopathological subtyping of non-small cell lung cancer (NSCLC) into adenocarcinoma (ADC), and squamous cell carcinoma (SqCC) is of utmost relevance for treatment stratification. However, current immunohistochemistry (IHC) based typing approaches on biopsies are imperfect, therefore novel analytical methods for reliable subtyping are needed. We analyzed formalin-fixed paraffin-embedded tissue cores of NSCLC by Matrix-assisted laser desorption/ionization (MALDI) imaging on tissue microarrays to identify and validate discriminating MALDI imaging profiles for NSCLC subtyping. 110 ADC and 98 SqCC were used to train a Linear Discriminant Analysis (LDA) model. Results were validated on a separate set of 58 ADC and 60 SqCC. Selected differentially expressed proteins were identified by tandem mass spectrometry and validated by IHC. The LDA classification model incorporated 339 m/z values. In the validation cohort, in 117 cases (99.1%) MALDI classification on tissue cores was in accordance with the pathological diagnosis made on resection specimen. Overall, three cases in the combined cohorts were discordant, after reevaluation two were initially misclassified by pathology whereas one was classified incorrectly by MALDI. Identification of differentially expressed peptides detected well-known IHC discriminators (CK5, CK7), but also less well known differentially expressed proteins (CK15, HSP27). In conclusion, MALDI imaging on NSCLC tissue cores as small biopsy equivalents is capable to discriminate lung ADC and SqCC with a very high accuracy. In addition, replacing multislide IHC by an one-slide MALDI approach may also save tissue for subsequent predictive molecular testing. We therefore advocate to pursue routine diagnostic implementation strategies for MALDI imaging in solid tumor typing. © 2016 by The American Society for Biochemistry and Molecular Biology, Inc.
Zorn, Kevin C; Gofrit, Ofer N; Steinberg, Gary P; Taxy, Jerome B; Zagaja, Gregory P; Shalhav, Arieh L
2008-06-01
The main objective of radical prostatectomy (RP) is optimal oncologic resection with preservation of sexual function (SF). During our initial experience with robot-assisted laparoscopic radical prostatectomy (RLRP), we noted a high rate of posterolateral location of positive surgical margins (PSM) with nerve preservation (NP). With its magnified view of the surgical field and improved instrument precision, one potential advantage of RLRP is the ability to tailor the degree of NP. We evaluated the effect of a protocol for side-specific NP based on preoperative variables on PSM rates and SF outcomes. Between June and November 2006, 150 consecutive RLRPs were performed using a surgical protocol to select side-specific NP techniques (interfascial [IF], partial extrafascial [pEF], and wide extrafascial resection [WEFR]) based on preoperative risk factors (clinical stage, biopsy Gleason score, percentage of positive cores and maximal core cancer percentage, and preoperative PSA). Pathologic and SF outcomes in these patients were compared with those of a control group of 245 consecutive RLRPs in whom non-selective IF dissection was performed. All data were prospectively collected. Mean patient age, PSA, clinical stage, biopsy Gleason score and positive core involvement, pathologic Gleason score, and stage were comparable among the two groups. The overall PSM rate (12.6% nu 20.4%; P = 0.04) and posterolateral location of PSMs (37% nu 70%; P = 0.04) were significantly lower in the study group. At 12 months, potency was reported in 80%, 67%, and 11% of men undergoing bilateral IFNP, partial extrafascial nerve preservation (pEFNP), and WEFR, respectively (P = 0.27). Planning side-specific NP during RLRP, according to selected preoperative variables, can significantly reduce overall and posterolateral PSM rates. Furthermore, partial nerve sparing (pEFNP) also appears to confer favorable early SF outcomes.
Core biopsy as a simple and effective diagnostic tool in head and neck focal myositis.
Tan, Chun Yee; Chong, Sheldon; Shaw, Chi-Kee Leslie
2015-12-01
Most unilateral head and neck masses are benign, although malignancy is a possibility in some cases. However, there are other rare causes of unilateral neck masses, such as focal myositis, which is a rare, benign condition belonging to the family of inflammatory pseudotumors of the skeletal muscles, with rare presentations in the head and neck region. Focal myositis presents as a rapidly enlarging neck mass that can be misdiagnosed by fine-needle aspiration biopsy and/or radiologic imaging as either an infective or a neoplastic process. To date, there are only 5 reported cases of adult focal myositis of the sternocleidomastoid muscle in the medical literature. In this article, the authors present 2 cases involving patients with focal myositis of the sternocleidomastoid muscle that were successfully diagnosed with core-needle biopsy and managed conservatively. The pros and cons of fine-needle aspiration biopsy and core-needle biopsy are discussed. Based on the authors' results, fine-needle aspiration biopsy universally fails to provide the diagnosis of focal myositis. In contrast, core-needle biopsy successfully diagnosed focal myositis in both of our patients. Both of them had complete resolution with conservative management.
Contemporary prostate biopsy reporting: insights from a survey of clinicians' use of pathology data.
Varma, Murali; Narahari, Krishna; Mason, Malcolm; Oxley, Jon D; Berney, Daniel M
2018-05-02
To determine how clinicians use data in contemporary prostate biopsy reports. A survey was circulated to members of the British Association of Urological Surgeons and the British Uro-oncology Group. Responses were received from 114 respondents (88 urologists, 26 oncologists). Ninety-seven (94%) use the number of positive cores from each side and 43 (42%) use the % number of positive cores. When determining the number and percentage of positive cores, 72 (71%) would not differentiate between targeted and non-targeted samples. If multiple Gleason Scores (GS) were included in a report, 77 (78%) would use the worst GS even if present in a core with very little tumour, 12% would use the global GS and 10% the GS in the core most involved by tumour. Fifty-five (55%) either never or rarely used perineural invasion for patient management. The number of positive cores is an important parameter for patient management but may be difficult to determine in the laboratory due to core fragmentation so the biopsy taker must indicate the number of biopsies obtained. Multiple biopsies taken from a single site are often interpreted by clinicians as separate cores when determining the number of positive cores so pathologists should also report the number of sites positive. Clinicians have a non-uniform approach to the interpretation of multiple GS in prostate biopsy reports so we recommend that pathologists also include a single 'bottom-line' GS for each case to direct the clinician's treatment decision. © Article author(s) (or their employer(s) unless otherwise stated in the text of the article) 2018. All rights reserved. No commercial use is permitted unless otherwise expressly granted.
Serfling, Robert; Ogola, Gerald
2016-02-10
Among men, prostate cancer (CaP) is the most common newly diagnosed cancer and the second leading cause of death from cancer. A major issue of very large scale is avoiding both over-treatment and under-treatment of CaP cases. The central challenge is deciding clinical significance or insignificance when the CaP biopsy results are positive but only marginally so. A related concern is deciding how to increase the number of biopsy cores for larger prostates. As a foundation for improved choice of number of cores and improved interpretation of biopsy results, we develop a probability model for the number of positive cores found in a biopsy, given the total number of cores, the volumes of the tumor nodules, and - very importantly - the prostate volume. Also, three applications are carried out: guidelines for the number of cores as a function of prostate volume, decision rules for insignificant versus significant CaP using number of positive cores, and, using prior distributions on total tumor size, Bayesian posterior probabilities for insignificant CaP and posterior median CaP. The model-based results have generality of application, take prostate volume into account, and provide attractive tradeoffs of specificity versus sensitivity. Copyright © 2015 John Wiley & Sons, Ltd. Copyright © 2015 John Wiley & Sons, Ltd.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Stattaus, Joerg, E-mail: joerg.stattaus@uni-due.de; Kalkmann, Janine, E-mail: janine.kalkmann@uk-essen.de; Kuehl, Hilmar, E-mail: hilmar.kuehl@uni-due.d
2008-09-15
The purpose of this study was to evaluate the diagnostic yield of core biopsy in coaxial technique under guidance of computed tomography (CT) for retroperitoneal masses. We performed a retrospective analysis of CT-guided coaxial core biopsies of undetermined masses in the non-organ-bound retroperitoneal space in 49 patients. In 37 cases a 15-G guidance needle with a 16-G semiautomated core biopsy system, and in 12 cases a 16-G guidance needle with an 18-G biopsy system, was used. All biopsies were technically successful. A small hematoma was seen in one case, but no relevant complication occurred. With the coaxial technique, up tomore » 4 specimens were obtained from each lesion (mean, 2.8). Diagnostic accuracy in differentiation between malignant and benign diseases was 95.9%. A specific histological diagnosis could be established in 39 of 42 malignant lesions (92.9%). Correct subtyping of malignant lymphoma according to the WHO classification was possible in 87.0%. Benign lesions were correctly identified in seven cases, although a specific diagnosis could only be made in conjunction with clinical and radiological information. In conclusion, CT-guided coaxial core biopsy provides safe and accurate diagnosis of retroperitoneal masses. A specific histological diagnosis, which is essential for choosing the appropriate therapy, could be established in most cases of malignancy.« less
Predicting Prostate Cancer Progression at Time of Diagnosis
2013-07-01
Freedland SJ, Aronson WJ, Terris MK, Kane CJ, Amling CL, Dorey F, et al. Percent of prostate needle biopsy cores with cancer is significant...defined by the percent of biopsy cores with tumor involvement, associated with specimen collection. Lin et al. Clin Cancer Res; 19(9) May 1, 2013 Clinical...OnlineFirst March 20, 2013; DOI: 10.1158/1078-0432.CCR-12-3283 was defined as the percentage of biopsy cores with cancer involvement. PCA3 and TMPRSS2
Cohen, Micah G; McMahon, Colm J; Kung, Justin W; Wu, Jim S
2016-05-01
The purpose of this study was to compare manual and battery-powered bone biopsy systems for diagnostic yield and procedural factors during core needle biopsy of sclerotic bone lesions. A total of 155 consecutive CT-guided core needle biopsies of sclerotic bone lesions were performed at one institution from January 2006 to November 2014. Before March 2012, lesions were biopsied with manual bone drill systems. After March 2012, most biopsies were performed with a battery-powered system and either noncoaxial or coaxial biopsy needles. Diagnostic yield, crush artifact, CT procedure time, procedure radiation dose, conscious sedation dose, and complications were compared between the manual and battery-powered core needle biopsy systems by Fisher exact test and t test. One-way ANOVA was used for subgroup analysis of the two battery-powered systems for procedure time and radiation dose. The diagnostic yield for all sclerotic lesions was 60.0% (93/155) and was significantly higher with the battery-powered system (73.0% [27/37]) than with the manual systems (55.9% [66/118]) (p = 0.047). There was no significant difference between the two systems in terms of crush artifact, procedure time, radiation dose, conscious sedation administered, or complications. In subgroup analysis, the coaxial battery-powered biopsies had shorter procedure times (p = 0.01) and lower radiation doses (p = 0.002) than the coaxial manual systems, but the noncoaxial battery-powered biopsies had longer average procedure times and higher radiation doses than the coaxial manual systems. In biopsy of sclerotic bone lesions, use of a battery-powered bone drill system improves diagnostic yield over use of a manual system.
Ukimura, Osamu; Marien, Arnaud; Palmer, Suzanne; Villers, Arnauld; Aron, Manju; de Castro Abreu, Andre Luis; Leslie, Scott; Shoji, Sunao; Matsugasumi, Toru; Gross, Mitchell; Dasgupta, Prokar; Gill, Inderbir S
2015-11-01
To compare the diagnostic yield of targeted prostate biopsy using image-fusion of multi-parametric magnetic resonance (mp-MR) with real-time trans-rectal ultrasound (TRUS) for clinically significant lesions that are suspicious only on mp-MR versus lesions that are suspicious on both mp-MR and TRUS. Pre-biopsy MRI and TRUS were each scaled on a 3-point score: highly suspicious, likely, and unlikely for clinically significant cancer (sPCa). Using an MR-TRUS elastic image-fusion system (Koelis), a 127 consecutive patients with a suspicious clinically significant index lesion on pre-biopsy mp-MR underwent systematic biopsies and MR/US-fusion targeted biopsies (01/2010-09/2013). Biopsy histological outcomes were retrospectively compared with MR suspicion level and TRUS-visibility of the MR-suspicious lesion. sPCa was defined as biopsy Gleason score ≥7 and/or maximum cancer core length ≥5 mm. Targeted biopsies outperformed systematic biopsies in overall cancer detection rate (61 vs. 41 %; p = 0.007), sPCa detection rate (43 vs. 23 %; p = 0.0013), cancer core length (7.5 vs. 3.9 mm; p = 0.0002), and cancer rate per core (56 vs. 12 %; p < 0.0001), respectively. Highly suspicious lesions on mp-MR correlated with higher positive biopsy rate (p < 0.0001), higher Gleason score (p = 0.018), and greater cancer core length (p < 0.0001). Highly suspicious lesions on TRUS in corresponding to MR-suspicious lesion had a higher biopsy yield (p < 0.0001) and higher sPCa detection rate (p < 0.0001). Since majority of MR-suspicious lesions were also suspicious on TRUS, TRUS-visibility allowed selection of the specific MR-visible lesion which should be targeted from among the multiple TRUS suspicious lesions in each prostate. MR-TRUS fusion-image-guided biopsies outperformed systematic biopsies. TRUS-visibility of a MR-suspicious lesion facilitates image-guided biopsies, resulting in higher detection of significant cancer.
Symbol, Brittany; Ricci, Andrew
2018-04-23
Due to the potential for atypia (atypical ductal or lobular hyperplasia) or carcinoma (in situ or invasive) on excision, aggressive reflex surgical excision protocols following core biopsy diagnosis of papillary lesions of the breast (ie, intraductal papilloma) are commonplace. Concepts in risk stratification, including radiologic-pathologic correlation, are emerging in an effort to curb unnecessary surgeries. To this end, we examined all excised intraductal papillomas diagnosed at our institution from 2010-2015 (N = 336) and found an overall atypia rate of 20%. To investigate further, we stratified all excised papillomas according to total lesion size (range = 1-40 mm) and found that the atypia rate for lesions ≤1.2 cm (16% with atypia) was statistically significantly lower (P = .008) than the atypia rate for lesions >1.2 cm (36% with atypia). To explore to effects of radiologic-pathologic correlation on the ability of the core biopsy to accurately predict nonatypical lesions we assessed thirteen consecutive paired nonatypical core biopsy/follow-up surgical excision specimens for the percent of the total lesion (on imaging) sampled by the core biopsy (measured histologically). None of the thirteen paired specimens showed upgrade on excision (0/13); the percent of total lesion sampled by biopsy in this cohort averaged 59%. We propose that in the absence of discordant clinical/radiological findings, small lesions (≤1.2 cm) with radiologic-pathologic concordance (>50% sampling of total lesion by core biopsy) may safely forego surgery for close clinical and radiographic follow-up. © 2018 Wiley Periodicals, Inc.
Cheurfa, N; Giard, S
2015-01-01
Despite the standard management of non-palpable breast cancer (needle core biopsy diagnostic, accurate preoperative localization), there are differences in some cases between the malignant histo-pathological finding in diagnostic biopsy results and negative histo-pathological finding after surgical excision. The aim of this study is to evaluate this incidence and classifying them under three category: failure of surgical excision after preoperative identification; removal of the tumor was already completed by percutaneous biopsy; percutaneous biopsy true false positive. We conducted a study based on prospective database, all patients included in this study had partial mastectomy for ductal carcinoma in-situ or invasive cancer which was diagnosed by needle core biopsy and normal/benign after surgery. Regarding the partial mastectomy, 1863 was performed in the last three years in our center. Thirty-seven patients (2%) correspond our study criteria. After discussion of cases in our multidisciplinary reunion, 6 patients (16%) were considered as failure of surgical excision, 26 patients (70%) as true removal of the whole lesion in the core, and 5 patients (13%) as true false-positive cores. This is the first study witch investigate all factors that influence the results of negative final histo-pathological finding of surgical excision of the tumor after malignant diagnostic needle core biopsy. This rare situation need a multidisciplinary meeting to analyse all the steps of management and to determine causes of those false results and try to find adequate management to solve this problem. Copyright © 2014 Elsevier Masson SAS. All rights reserved.
Subsequent Breast Cancer Risk Following Diagnosis of Atypical Ductal Hyperplasia on Needle Biopsy
Menes, Tehillah S; Kerlikowske, Karla; Lange, Jane; Jaffer, Shabnam; Rosenberg, Robert; Miglioretti, Diana L.
2017-01-01
Background Atypical ductal hyperplasia (ADH) is a known strong risk factor for breast cancer. Published risk estimates are based on cohorts that included women diagnosed prior to the widespread use of screening mammograms and do not differentiate between the methods used to diagnose ADH, which may be related to size of the ADH focus. These risks may overestimate the risk of women currently diagnosed with ADH. We sought to examine the risk of invasive cancer associated with ADH diagnosed on core needle biopsy versus excisional biopsy. Design Cohort study comparing ten-year cumulative risk of invasive breast cancer in women undergoing mammography with and without a diagnosis of ADH. Setting Five breast imaging registries that participate in the National Cancer Institute–funded Breast Cancer Surveillance Consortium (BCSC). Participants Women undergoing mammography in the BCSC. Exposure Diagnosis of ADH on core needle biopsy or excisional biopsy in women undergoing mammography. Main outcome Ten-year cumulative risk of invasive breast cancer risk. Results The sample included 955,331 women with 1,727 diagnoses of ADH. From 1996 to 2012, the proportion of ADH diagnosed by core needle biopsy increased from 21% to 77%. Ten years following a diagnosis of ADH, the cumulative risk of invasive breast cancer was 2.6 (95% CI 2.0, 3.4) times higher than risk in women with no ADH. ADH diagnosed via excisional biopsy was associated with an adjusted HR of 3.0 (95% CI 2.0, 4.5), and via core needle biopsy, with an HR of 2.2 (95% CI 1.5, 3.4). Ten years after an ADH diagnosis, an estimated 5.7% (95% CI 4.3, 10.1) of women were diagnosed with invasive cancer. Women with ADH diagnosed on excisional biopsy had a slightly higher risk (6.7 %; 95% CI 3.0, 12.8) compared to those with ADH diagnosed via core needle biopsy (5.0%; 95% CI 2.2, 8.9). Conclusions Current 10-year risks of invasive breast cancer after a diagnosis of ADH may be lower than previously reported. The risk associated with ADH is slightly lower for women diagnosed by needle core biopsy as compared to excisional biopsy. PMID:27607465
Ma, Qi; Yang, Dong-Rong; Xue, Bo-Xin; Wang, Cheng; Chen, Han-Bin; Dong, Yun; Wang, Cai-Shan; Shan, Yu-Xi
2017-07-01
The focus of the present study was to evaluate transrectal real-time tissue elastography (RTE)-targeted two-core biopsy coupled with peak strain index for the detection of prostate cancer (PCa) and to compare this method with 10-core systematic biopsy. A total of 141 patients were enrolled for evaluation. The diagnostic value of peak strain index was assessed using a receiver operating characteristic curve. The cancer detection rates of the two approaches and corresponding positive cores and Gleason score were compared. The cancer detection rate per core in the RTE-targeted biopsy (44%) was higher compared with that in systematic biopsy (30%). The peak strain index value of PCa was higher compared with that of the benign lesion. PCa was detected with the highest sensitivity (87.5%) and specificity (85.5%) using the threshold value of a peak strain index of ≥5.97 with an area under the curve value of 0.95. When the Gleason score was ≥7, RTE-targeted biopsy coupled with peak strain index detected 95.6% of PCa cases, but 84.4% were detected using systematic biopsy. Peak strain index as a quantitative parameter may improve the differentiation of PCa from benign lesions in the prostate peripheral zone. Transrectal RTE-targeted biopsy coupled with peak strain index may enhance the detection of clinically significant PCa, particularly when combined with systematic biopsy.
Del Cura, Jose Luis; Coronado, Gloria; Zabala, Rosa; Korta, Igone; López, Ignacio
2018-01-31
To review the diagnostic accuracy of ultrasound-guided core-needle biopsy (CNB) in the diagnosis of salivary gland tumours (SGT). Retrospective, institutional review board approved, analysis of the CNB of SGT performed at our centre in 8 years. We used an automatic 18-G spring-loaded device. The final diagnosis was based on surgery in the cases that were operated on, and on clinical evolution and biopsy findings in the rest. Four hundred and nine biopsies were performed in 381 patients (ages, 2-97 years; mean, 55.9). There were two minor complications. Biopsy was diagnostic in 98.3%. There were eight false negatives. The diagnostic values for malignancy were: sensitivity 89.6%, specificity 100%, positive predictive value (PPV) 100% and negative predictive value (NPV) 98%. For the detection of neoplasms were: sensitivity 98.7%, specificity 99%, PPV 99.7% and VPN 96.1%. Accuracy of CNB in SGT is very high, with a very high sensitivity and an absolutely reliable diagnosis of malignancy. Complication rate is very low. It should be considered the technique of choice when a STG is detected. Normal tissue results warrant repeating biopsy. • Ultrasound-guided core-biopsy is the technique of choice in salivary glands nodules • Sensitivity, specificity for detecting neoplasms (which should be resected) are around 99% • Diagnosis of malignancy in core-biopsy is absolutely reliable • A CNB result of "normal tissue", however, warrants repeating the biopsy • Complication rate is very low.
Wang, Hailing; Li, Fangxuan; Liu, Juntian; Zhang, Sheng
2014-01-01
Ultrasound-guided core needle biopsy of abdominal and pelvic masses in adults has gained tremendous popularity. However, the application of the same treatment in children is not as popular because of apprehensions regarding inadequate tissues for the biopsy and accidental puncture of vital organs. Data of the application of ultrasound-guided core needle biopsy in 105 pediatric patients with clinically or ultrasound-diagnosed abdominopelvic masses were reviewed. Diagnostic procedures were conducted in our institution from May 2011 to May 2013. The biopsies were conducted on 86 malignant lesions and 19 benign lesions. 86 malignant tumors comprised neuroblastomas (30 cases), hepatoblastomas (15 cases), nephroblastomas (11 cases), and primitive neuroectodermal tumors/malignant small round cells (6 cases). Among malignant tumor cases, only a pelvic primitive neuroectodermal tumor did not receive a pathological diagnosis. Therefore, the biopsy accuracy was 98.8 % in malignant tumor. However, the biopsies for one neuroblastomas and one malignant small round cell tumor were inadequate for cytogenetic analysis. Therefore, 96.5 % of the malignant tumor patients received complete diagnosis via biopsy. 19 benign tumors comprised mature teratoma (10 cases), hemangioendothelioma (3 cases), paraganglioma (2 cases), and infection (2 cases). The diagnostic accuracy for benign neoplasm was 100 %. Five patients experienced postoperative complications, including pain (2 patients), bleeding from the biopsy site (2 patients), and wound infection (1 patient). Ultrasound-guided core needle biopsy is an efficient, minimally invasive, accurate, and safe diagnostic method that can be applied in the management of abdominal or pelvic mass of pediatric patients.
Arsov, Christian; Rabenalt, Robert; Blondin, Dirk; Quentin, Michael; Hiester, Andreas; Godehardt, Erhard; Gabbert, Helmut E; Becker, Nikolaus; Antoch, Gerald; Albers, Peter; Schimmöller, Lars
2015-10-01
A significant proportion of prostate cancers (PCas) are missed by conventional transrectal ultrasound-guided biopsy (TRUS-GB). It remains unclear whether the combined approach using targeted magnetic resonance imaging (MRI)-ultrasound fusion-guided biopsy (FUS-GB) and systematic TRUS-GB is superior to targeted MRI-guided in-bore biopsy (IB-GB) for PCa detection. To compare PCa detection between IB-GB alone and FUS-GB + TRUS-GB in patients with at least one negative TRUS-GB and prostate-specific antigen ≥4 ng/ml. Patients were prospectively randomized after multiparametric prostate MRI to IB-GB (arm A) or FUS-GB + TRUS-GB (arm B) from November 2011 to July 2014. The study was powered at 80% to demonstrate an overall PCa detection rate of ≥60% in arm B compared to 40% in arm A. Secondary endpoints were the distribution of highest Gleason scores, the rate of detection of significant PCa (Gleason ≥7), the number of biopsy cores to detect one (significant) PCa, the positivity rate for biopsy cores, and tumor involvement per biopsy core. The study was halted after interim analysis because the primary endpoint was not met. The trial enrolled 267 patients, of whom 210 were analyzed (106 randomized to arm A and 104 to arm B). PCa detection was 37% in arm A and 39% in arm B (95% confidence interval for difference, -16% to 11%; p=0.7). Detection rates for significant PCa (29% vs 32%; p=0.7) and the highest percentage tumor involvement per biopsy core (48% vs 42%; p=0.4) were similar between the arms. The mean number of cores was 5.6 versus 17 (p<0.001). A limitation is the limited number of patients because of early cessation of accrual. This trial failed to identify an important improvement in detection rate for the combined biopsy approach over MRI-targeted biopsy alone. A prospective comparison between MRI-targeted biopsy alone and systematic TRUS-GB is justified. Our randomized study showed similar prostate cancer detection rates between targeted prostate biopsy guided by magnetic resonance imaging and the combination of targeted biopsy and systematic transrectal ultrasound-guided prostate biopsy. An important improvement in detection rates using the combined biopsy approach can be excluded. Copyright © 2015 European Association of Urology. Published by Elsevier B.V. All rights reserved.
Number of Biopsies in Diagnosing Pulmonary Nodules
Wehrschuetz, M.; Wehrschuetz, E.; Portugaller, H. R.
2010-01-01
Purpose: To determine the number of specimens to be obtained from pulmonary lesions to get the highest possible accuracy in histological work-up. Materials and methods: A retrospective evaluation (January 1999 to April 2004) covered 260 patients with thoracic lesions who underwent computer tomography (CT)-guided core-cut biopsy in coaxial technique. All biopsies were performed utilizing a 19 gauge introducer needle and a 20 gauge core-cut biopsy needle. In all, 669 usable biopsies were taken (from 1–5 biopsies in each setting). The specimens were marked sequentially and each biopsy was worked up histologicaly. The biopsy results were correlated to histology after surgery, clinical follow-up or autopsy. The number of biopsies was determined that is necessary to achieve the highest possible accuracy in diagnosing pulmonary lesions. Results: In 591 of 669 biopsies (88.3%), there were correct positive results. The overall accuracy was 87.4%. In 193 of 260 (74.2%) patients, a suspected malignancy was confirmed. In 50 of 260 (19.2%) patients, a benign lesion was correctly diagnosed. Seventeen (6.5%) patients were lost to follow-up. The first, second and third biopsies had cumulative accuracies of 63.6%, 89.2% and 91.5%, respectively (P < 0.02). More biopsies did not show any higher impact on accuracy. Conclusion: For the highest possible accuracy in diagnosing pulmonary lesions by CT-guided core-cut biopsy, at least three usable specimens are recommended to be taken. PMID:21157523
Vacuum-assisted drainage in cardiopulmonary bypass: advantages and disadvantages.
Carvalho Filho, Elio Barreto de; Marson, Fernando Augusto de Lima; Costa, Loredana Nilkenes Gomes da; Antunes, Nilson
2014-01-01
Systematic review of vacuum assisted drainage in cardiopulmonary bypass, demonstrating its advantages and disadvantages, by case reports and evidence about its effects on microcirculation. We conducted a systematic search on the period 1997-2012, in the databases PubMed, Medline, Lilacs and SciELO. Of the 70 selected articles, 26 were included in the review. Although the vacuum assisted drainage has significant potential for complications and requires appropriate technology and professionalism, prevailed in literature reviewed the concept that vacuum assisted drainage contributed in reducing the rate of transfusions, hemodilutions, better operative field, no significant increase in hemolysis, reduced complications surgical, use of lower prime and of smaller diameter cannulas.
Suba, Eric J; Pfeifer, John D; Raab, Stephen S
2007-10-01
Patient identification errors in surgical pathology often involve switches of prostate or breast needle core biopsy specimens among patients. We assessed strategies for decreasing the occurrence of these uncommon and yet potentially catastrophic events. Root cause analyses were performed following 3 cases of patient identification error involving prostate needle core biopsy specimens. Patient identification errors in surgical pathology result from slips and lapses of automatic human action that may occur at numerous steps during pre-laboratory, laboratory and post-laboratory work flow processes. Patient identification errors among prostate needle biopsies may be difficult to entirely prevent through the optimization of work flow processes. A DNA time-out, whereby DNA polymorphic microsatellite analysis is used to confirm patient identification before radiation therapy or radical surgery, may eliminate patient identification errors among needle biopsies.
Window-assisted nanosphere lithography for vacuum micro-nano-electronics
DOE Office of Scientific and Technical Information (OSTI.GOV)
Li, Nannan; Institute of Electronic Engineering, Chinese Academy of Engineering Physics, Mianyang, 621900; Pang, Shucai
2015-04-15
Development of vacuum micro-nano-electronics is quite important for combining the advantages of vacuum tubes and solid-state devices but limited by the prevailing fabricating techniques which are expensive, time consuming and low-throughput. In this work, window-assisted nanosphere lithography (NSL) technique was proposed and enabled the low-cost and high-efficiency fabrication of nanostructures for vacuum micro-nano-electronic devices, thus allowing potential applications in many areas. As a demonstration, we fabricated high-density field emitter arrays which can be used as cold cathodes in vacuum micro-nano-electronic devices by using the window-assisted NSL technique. The details of the fabricating process have been investigated. This work provided amore » new and feasible idea for fabricating nanostructure arrays for vacuum micro-nano-electronic devices, which would spawn the development of vacuum micro-nano-electronics.« less
Core Needle Lung Biopsy Specimens: Adequacy for EGFR and KRAS Mutational Analysis
Zakowski, Maureen F.; Pao, William; Thornton, Raymond H.; Ladanyi, Marc; Kris, Mark G.; Rusch, Valerie W.; Rizvi, Naiyer A.
2013-01-01
OBJECTIVE The purpose of this study was to prospectively compare the adequacy of core needle biopsy specimens with the adequacy of specimens from resected tissue, the histologic reference standard, for mutational analysis of malignant tumors of the lung. SUBJECTS AND METHODS The first 18 patients enrolled in a phase 2 study of gefitinib for lung cancer in July 2004 through August 2005 underwent CT- or fluoroscopy-guided lung biopsy before the start of gefitinib therapy. Three weeks after gefitinib therapy, the patients underwent lung tumor resection. The results of EGFR and KRAS mutational analysis of the core needle biopsy specimens were compared with those of EGFR and KRAS mutational analysis of the surgical specimens. RESULTS Two specimens were unsatisfactory for mutational analysis. The results of mutational assay results of the other 16 specimens were the same as those of analysis of the surgical specimens obtained an average of 31 days after biopsy. CONCLUSION Biopsy with small (18- to 20-gauge) core needles can yield sufficient and reliable samples for mutational analysis. This technique is likely to become an important tool with the increasing use of pharmacotherapy based on the genetics of specific tumors in individual patients. PMID:20028932
Frank, Leslie Smith; Frank, James L; March, David; Makari-Judson, Grace; Barham, Ruth B; Mertens, Wilson C
2007-01-01
To determine whether therapeutic touch administered at the time of stereotactic core biopsy of suspicious breast lesions results in a reduction in anxiety and pain. Randomized, patient-blinded, controlled trial of either Krieger-Kunz therapeutic touch administered by a trained practitioner or a sham intervention mimicking therapeutic touch delivered during core biopsy. Stereotactic breast biopsy unit of a comprehensive breast center. Women with mammographically detected, nonpalpable breast lesions requiring biopsy. Changes in pain and anxiety measured by visual analog scales immediately before and after stereotactic core biopsy. A total of 82 patients were accrued: 42 received actual therapeutic touch and 40 sham therapeutic touch. No significant differences were found between the arms for age, ethnicity, educational background, or other demographic data. The sham arm had a preponderance of left breast biopsies (48% vs 58%; P = 0.07) and received a slightly higher volume of epinephrine-containing local anesthetic (6.5 +/- 6.1 vs 4.5 +/- 4.5 mL; P = 0.09). Therapeutic touch patients were more likely to have an upper breast lesion location (57% vs 53%; P = 0.022). No significant differences between the arms were seen regarding postbiopsy pain (P = 0.95), anxiety (P = 0.66), fearfulness, or physiological parameters. Similarly, no differences were seen between the arms when change in parameters from prebiopsy to postbiopsy was considered for any of the psychological or physiological variables measured. These findings persisted when confounding variables were controlled for. Women undergoing stereotactic core breast biopsy received no significant benefit from therapeutic touch administered during the procedure. Therapeutic touch cannot be routinely recommended for patients in this setting.
Calhoun, Benjamin C; Sobel, Amy; White, Richard L; Gromet, Matt; Flippo, Teresa; Sarantou, Terry; Livasy, Chad A
2015-05-01
Flat epithelial atypia of the breast commonly co-exists with atypical ductal hyperplasia, lobular neoplasia, and indolent forms of invasive carcinomas such as tubular carcinoma. Most patients with pure flat epithelial atypia on core biopsy undergo surgical excision to evaluate for carcinoma in the adjacent breast tissue. Studies to date have reported varying upgrade rates with most recommending follow-up excision. These studies have often lacked detailed radiographic correlation, central review by breast pathologists and information regarding the biology of the carcinomas identified upon excision. In this study, we report the frequency of upgrade to invasive carcinoma or ductal carcinoma in situ in excision specimens following a diagnosis of pure flat epithelial atypia on core biopsy. Radiographic correlation is performed for each case and grade/receptor status of detected carcinomas is reported. Seventy-three (73) core biopsies containing pure flat epithelial atypia were identified from our files, meeting inclusion criteria for the study. In the subsequent excision biopsies, five (7%) cases contained invasive carcinoma or ductal carcinoma in situ and seventeen (23%) contained atypical ductal hyperplasia or lobular neoplasia. All of the ductal carcinoma in situ cases with estrogen receptor results were estrogen receptor positive and intermediate grade. The invasive tumors were small (pT1a) hormone receptor-positive, HER2-negative, low-grade invasive ductal or tubular carcinomas with negative sentinel lymph-node biopsies. No upgrades were identified in the 14 patients who had all of their calcifications removed by the stereotactic core biopsy. Our rate of upgrade to carcinoma, once cases with discordant imaging are excluded, is at the lower end of the range reported in the literature. Given the low upgrade rate and indolent nature of the carcinomas associated with flat epithelial atypia, case management may be individualized based on clinical and radiographic findings. Excision may not be necessary for patients without remaining calcifications following core biopsy.
Use of Indocyanine Green for Sentinel Lymph Node Biopsy: Case Series and Methods Comparison.
McGregor, Andrew; Pavri, Sabrina N; Tsay, Cynthia; Kim, Samuel; Narayan, Deepak
2017-11-01
Sentinel lymph node biopsy is indicated for patients with biopsy-proven thickness melanoma greater than 1.0 mm. Use of lymphoscintigraphy along with vital blue dyes is the gold standard for identifying sentinel lymph nodes intraoperatively. Indocyanine green (ICG) has recently been used as a method of identifying sentinel lymph nodes. We herein describe a case series of patients who have successfully undergone ICG-assisted sentinel lymph node biopsy for melanoma. We compare 2 imaging systems that are used for ICG-assisted sentinel lymph node biopsy. Fourteen patients underwent ICG-assisted sentinel lymph node biopsy for melanoma using the SPY Elite system (Novadaq, Mississigua, Canada) and the Hamamatsu PDE-Neo probe system (Mitaka USA, Park City, Utah). We analyzed costs for 2 systems that utilize ICG for sentinel lymph node biopsies. Intraoperative use of ICG for sentinel lymph node biopsies was successful in correctly identifying sentinel lymph nodes. There was no difference between the Hamamatsu PDE-Neo probe and SPY Elite systems in the ability to detect sentinel lymph nodes; however, the former was associated with a lower operating cost and ease of use compared with the latter. ICG-assisted sentinel lymph biopsy using the SPY Elite or the Hamamatsu PDE-Neo probe systems for melanoma are comparable in terms of sentinel node detection. The Neo probe system delivers pertinent clinical data with the advantages of lower cost and ease of operation.
Rapp, David E; Msezane, Lambda P; Reynolds, W Stuart; Lotan, Tamara L; Obara, Piotr; O'Connor, R Corey; Taxy, Jerome B; Gerber, Glenn S; Zagaja, Gregory P
2009-02-01
We sought to evaluate the ability of biopsy core recutting to increase cancer detection in patients with high grade prostatic intraepithelial neoplasia (HGPIN). This prospective study encompasses all patients undergoing 12 core TRUS guided prostate biopsy between February 2004 and January 2007. In patients with HGPIN on initial biopsy, the paraffin blocks were resampled for cancer by additional deeper levels per core. Additional analysis was performed in the patients with HGPIN in order to detect whether significant differences in prebiopsy variables were associated with patients subsequently found to have benign versus carcinoma on recutting. Last, the costs associated with this procedure were studied. Forty of 584 (6.8%) patients undergoing prostate biopsy were found to have HGPIN in the absence of prostatic adenocarcinoma on initial histopathology. Following recutting, 12.5% (5/40) of these patients were found to have prostatic adenocarcinoma not previously detected. Of the remaining 35 patients, 18 underwent repeat biopsy. Of these, five patients were found to have adenocarcinoma and three were found to have persistent HGPIN. The PSA, PSA density (PSAD), and PSA velocity (PSAV) prior to initial biopsy were not statistically different when comparing patients found to have benign tissue versus carcinoma on recutting. In patients with HGPIN, at our institution, recutting the biopsy would yield a cost savings of $436/patient as opposed to universal rebiopsy. Our data suggest that prostate biopsy recutting may increase cancer detection in patients initially found to have HGPIN. Additionally, a significant cost savings is associated with the recutting protocol.
How accurate is our clinical prediction of "minimal prostate cancer"?
Leibovici, Dan; Shikanov, Sergey; Gofrit, Ofer N; Zagaja, Gregory P; Shilo, Yaniv; Shalhav, Arieh L
2013-07-01
Recommendations for active surveillance versus immediate treatment for low risk prostate cancer are based on biopsy and clinical data, assuming that a low volume of well-differentiated carcinoma will be associated with a low progression risk. However, the accuracy of clinical prediction of minimal prostate cancer (MPC) is unclear. To define preoperative predictors for MPC in prostatectomy specimens and to examine the accuracy of such prediction. Data collected on 1526 consecutive radical prostatectomy patients operated in a single center between 2003 and 2008 included: age, body mass index, preoperative prostate-specific antigen level, biopsy Gleason score, clinical stage, percentage of positive biopsy cores, and maximal core length (MCL) involvement. MPC was defined as < 5% of prostate volume involvement with organ-confined Gleason score < or = 6. Univariate and multivariate logistic regression analyses were used to define independent predictors of minimal disease. Classification and Regression Tree (CART) analysis was used to define cutoff values for the predictors and measure the accuracy of prediction. MPC was found in 241 patients (15.8%). Clinical stage, biopsy Gleason's score, percent of positive biopsy cores, and maximal involved core length were associated with minimal disease (OR 0.42, 0.1, 0.92, and 0.9, respectively). Independent predictors of MPC included: biopsy Gleason score, percent of positive cores and MCL (OR 0.21, 095 and 0.95, respectively). CART showed that when the MCL exceeded 11.5%, the likelihood of MPC was 3.8%. Conversely, when applying the most favorable preoperative conditions (Gleason < or = 6, < 20% positive cores, MCL < or = 11.5%) the chance of minimal disease was 41%. Biopsy Gleason score, the percent of positive cores and MCL are independently associated with MPC. While preoperative prediction of significant prostate cancer was accurate, clinical prediction of MPC was incorrect 59% of the time. Caution is necessary when implementing clinical data as selection criteria for active surveillance.
Vacuum-assisted drainage in cardiopulmonary bypass: advantages and disadvantages
de Carvalho Filho, Élio Barreto; Marson, Fernando Augusto de Lima; da Costa, Loredana Nilkenes Gomes; Antunes, Nilson
2014-01-01
Systematic review of vacuum assisted drainage in cardiopulmonary bypass, demonstrating its advantages and disadvantages, by case reports and evidence about its effects on microcirculation. We conducted a systematic search on the period 1997-2012, in the databases PubMed, Medline, Lilacs and SciELO. Of the 70 selected articles, 26 were included in the review. Although the vacuum assisted drainage has significant potential for complications and requires appropriate technology and professionalism, prevailed in literature reviewed the concept that vacuum assisted drainage contributed in reducing the rate of transfusions, hemodilutions, better operative field, no significant increase in hemolysis, reduced complications surgical, use of lower prime and of smaller diameter cannulas. PMID:25140478
2012-10-01
materials to facilitate dissemination of this technique. 15. SUBJECT TERMS Transfemoral amputation, sub-ischial socket, prosthesis , vacuum-assisted...an appropriate mechanical pump to create suitable vacuum for suspension of the prosthesis ...sockets of highly active prosthesis users
Shellikeri, Sphoorti; Setser, Randolph M; Hwang, Tiffany J; Srinivasan, Abhay; Krishnamurthy, Ganesh; Vatsky, Seth; Girard, Erin; Zhu, Xiaowei; Keller, Marc S; Cahill, Anne Marie
2017-07-01
Navigational software provides real-time fluoroscopic needle guidance for percutaneous procedures in the Interventional Radiology (IR) suite. We describe our experience with navigational software for pediatric percutaneous bone biopsies in the IR suite and compare technical success, diagnostic accuracy, radiation dose and procedure time with that of CT-guided biopsies. Pediatric bone biopsies performed using navigational software (Syngo iGuide, Siemens Healthcare) from 2011 to 2016 were prospectively included and anatomically matched CT-guided bone biopsies from 2008 to 2016 were retrospectively reviewed with institutional review board approval. C-arm CT protocols used for navigational software-assisted cases included institution-developed low-dose (0.1/0.17 μGy/projection), regular-dose (0.36 μGy/projection), or a combination of low-dose/regular-dose protocols. Estimated effective radiation dose and procedure times were compared between software-assisted and CT-guided biopsies. Twenty-six patients (15 male; mean age: 10 years) underwent software-assisted biopsies (15 pelvic, 7 lumbar and 4 lower extremity) and 33 patients (13 male; mean age: 9 years) underwent CT-guided biopsies (22 pelvic, 7 lumbar and 4 lower extremity). Both modality biopsies resulted in a 100% technical success rate. Twenty-five of 26 (96%) software-assisted and 29/33 (88%) CT-guided biopsies were diagnostic. Overall, the effective radiation dose was significantly lower in software-assisted than CT-guided cases (3.0±3.4 vs. 6.6±7.7 mSv, P=0.02). The effective dose difference was most dramatic in software-assisted cases using low-dose C-arm CT (1.2±1.8 vs. 6.6±7.7 mSv, P=0.001) or combined low-dose/regular-dose C-arm CT (1.9±2.4 vs. 6.6±7.7 mSv, P=0.04), whereas effective dose was comparable in software-assisted cases using regular-dose C-arm CT (6.0±3.5 vs. 6.6±7.7 mSv, P=0.7). Mean procedure time was significantly lower for software-assisted cases (91±54 vs. 141±68 min, P=0.005). In our experience, navigational software technology in the IR suite is a promising alternative to CT guidance for pediatric bone biopsies providing comparable technical success and diagnostic accuracy with lower radiation dose and procedure time, in addition to providing real-time fluoroscopic needle guidance.
Bramley, Kyle; Pisani, Margaret A.; Murphy, Terrence E.; Araujo, Katy; Homer, Robert; Puchalski, Jonathan
2016-01-01
Background EBUS-guided transbronchial needle aspiration (TBNA) is important in the evaluation of thoracic lymphadenopathy. Reliably providing excellent diagnostic yield for malignancy, its diagnosis of sarcoidosis is inconsistent. Furthermore, when larger “core” biopsy samples of malignant tissue are required, TBNA may not suffice. The primary objective of this study was to determine if the sequential use of TBNA and a novel technique called cautery-assisted transbronchial forceps biopsies (ca-TBFB) was safe. Secondary outcomes included sensitivity and successful acquisition of tissue. Methods Fifty unselected patients undergoing convex probe EBUS were prospectively enrolled. Under EBUS guidance, all lymph nodes ≥ 1 cm were sequentially biopsied using TBNA and ca-TBFB. Safety and sensitivity were assessed at the nodal level for 111 nodes. Results of each technique were also reported on a per-patient basis. Results There were no significant adverse events. In nodes determined to be malignant, TBNA provided higher sensitivity (100%) than ca-TBFB (78%). However, among nodes with granulomatous inflammation, ca-TBFB exhibited higher sensitivity (90%) than TBNA (33%). For analysis based on patients rather than nodes, 6 of the 31 patients with malignancy would have been missed or understaged if the diagnosis was based on samples obtained by ca-TBFB. On the other hand, 3 of 8 patients with sarcoidosis would have been missed if analysis was based only on TBNA samples. In some cases only ca-TBFB acquired sufficient tissue for the core samples needed in clinical trials of malignancy. Conclusions The sequential use of TBNA and ca-TBFB appears to be safe. The larger samples obtained from ca-TBFB increased its sensitivity to detect granulomatous disease and provided specimens for clinical trials of malignancy when needle biopsies were insufficient. For thoracic surgeons and advanced bronchoscopists, we advocate ca-TBFB as an alternative to TBNA in select clinical scenarios. PMID:26912301
Uematsu, T; Kasami, M; Uchida, Y; Sanuki, J; Kimura, K; Tanaka, K; Takahashi, K
2007-06-01
Hookwire localization is the current standard technique for radiological marking of nonpalpable breast lesions. Stereotactic directional vacuum-assisted breast biopsy (SVAB) is of sufficient sensitivity and specificity to replace surgical biopsy. Wire localization for metallic marker clips placed after SVAB is needed. To describe a method for performing computed tomography (CT)-guided hookwire localization using a radial approach for metallic marker clips placed percutaneously after SVAB. Nineteen women scheduled for SVAB with marker-clip placement, CT-guided wire localization of marker clips, and, eventually, surgical excision were prospectively entered into the study. CT-guided wire localization was performed with a radial approach, followed by placement of a localizing marker-clip surgical excision. Feasibility and reliability of the procedure and the incidence of complications were examined. CT-guided wire localization surgical excision was successfully performed in all 19 women without any complications. The mean total procedure time was 15 min. The median distance on CT image from marker clip to hookwire was 2 mm (range 0-3 mm). CT-guided preoperative hookwire localization with a radial approach for marker clips after SVAB is technically feasible.
2013-10-01
15. SUBJECT TERMS Transfemoral amputation, sub-ischial socket, prosthesis , vacuum-assisted suspension 16. SECURITY CLASSIFICATION OF: 17...vacuum for suspension of the prosthesis ...14 Task 6 Determine range of volumes to be evacuated from transfemoral sockets of highly active prosthesis users
Zamecnik, Patrik; Schouten, Martijn G; Krafft, Axel J; Maier, Florian; Schlemmer, Heinz-Peter; Barentsz, Jelle O; Bock, Michael; Fütterer, Jurgen J
2014-12-01
To assess the feasibility of automatic needle-guide tracking by using a real-time phase-only cross correlation ( POCC phase-only cross correlation ) algorithm-based sequence for transrectal 3-T in-bore magnetic resonance (MR)-guided prostate biopsies. This study was approved by the ethics review board, and written informed consent was obtained from all patients. Eleven patients with a prostate-specific antigen level of at least 4 ng/mL (4 μg/L) and at least one transrectal ultrasonography-guided biopsy session with negative findings were enrolled. Regions suspicious for cancer were identified on 3-T multiparametric MR images. During a subsequent MR-guided biopsy, the regions suspicious for cancer were reidentified and targeted by using the POCC phase-only cross correlation -based tracking sequence. Besides testing a general technical feasibility of the biopsy procedure by using the POCC phase-only cross correlation -based tracking sequence, the procedure times were measured, and a pathologic analysis of the biopsy cores was performed. Thirty-eight core samples were obtained from 25 regions suspicious for cancer. It was technically feasible to perform the POCC phase-only cross correlation -based biopsies in all regions suspicious for cancer in each patient, with adequate biopsy samples obtained with each biopsy attempt. The median size of the region suspicious for cancer was 8 mm (range, 4-13 mm). In each region suspicious for cancer (median number per patient, two; range, 1-4), a median of one core sample per region was obtained (range, 1-3). The median time for guidance per target was 1.5 minutes (range, 0.7-5 minutes). Nineteen of 38 core biopsy samples contained cancer. This study shows that it is feasible to perform transrectal 3-T MR-guided biopsies by using a POCC phase-only cross correlation algorithm-based real-time tracking sequence. © RSNA, 2014.
2014-10-01
Award Number: W81XWH-10-1-0744 TITLE: Development of Subischial Prosthetic Sockets with Vacuum...REPORT TYPE Annual 3. DATES COVERED 15 Sep 2013 – 14 Sep 2014 4. TITLE AND SUBTITLE Development of Subischial Prosthetic Sockets with Vacuum...to develop a highly flexible sub-ischial prosthetic socket with assisted-vacuum suspension for highly active persons with transfemoral amputation. The
Moreira, Daniel M; Nickel, J Curtis; Andriole, Gerald L; Castro-Santamaria, Ramiro; Freedland, Stephen J
2015-09-01
To evaluate whether baseline acute and chronic prostate inflammation among men with initial negative biopsy for prostate cancer (PC) is associated with PC volume at the 2-year repeat prostate biopsy in a clinical trial with systematic biopsies. Retrospective analysis of 886 men with negative baseline prostate biopsy and positive 2-year repeat biopsy in the Reduction by Dutasteride of PC Events (REDUCE) study. Acute and chronic inflammation and tumor volume were determined by central pathology. The association of baseline inflammation with 2-year repeat biopsy cancer volume was evaluated with linear and Poisson regressions controlling for demographics and laboratory variables. Chronic, acute inflammation, and both were detected in 531 (60%), 12 (1%), and 84 (9%) baseline biopsies, respectively. Acute and chronic inflammation were significantly associated with each other (P < 0.001). Chronic inflammation was associated with larger prostate (P < 0.001) and lower pre-repeat biopsy PSA (P = 0.01). At 2-year biopsy, baseline chronic inflammation was associated with lower mean tumor volume (2.07 µl vs. 3.15 µl; P = 0.001), number of biopsy cores involved (1.78 vs. 2.19; P < 0.001), percent of cores involved (17.8% vs. 22.8%; P < 0.001), core involvement (0.21 µl vs. 0.31 µl; P < 0.001), and overall percent tumor involvement (1.40% vs. 2.01%; P < 0.001). Results were unchanged in multivariable analysis. Baseline acute inflammation was not associated with any tumor volume measurement. In a cohort of men with 2-year repeat prostate biopsy positive for PC after a negative baseline biopsy, baseline chronic inflammation was associated with lower PC volume. © 2015 Wiley Periodicals, Inc.
Kryvenko, Oleksandr N
2017-06-01
There is limited literature on renal oncocytic neoplasms diagnosed on core biopsy. All renal oncocytic neoplasm core biopsies from 2006 to 2013 were, retrospectively, reviewed. Morphologic features and an immunohistochemical panel of CK7, c-KIT, and S100A1 were assessed. Concordance with resection diagnosis, statistical analysis including a random forest classification, and follow-up were recorded. The postimmunohistochemical diagnoses of 144 renal oncocytic core biopsies were favor oncocytoma (67%), favor renal cell carcinoma (RCC) (12%), and cannot exclude RCC (21%). Diagnosis was revised following immunohistochemistry in 7% of cases. The most common features for oncocytoma (excluding dense granular cytoplasm) were nested architecture, edematous stroma, binucleation and tubular architecture; the most common features for favor RCC were sheet-like architecture, nuclear pleomorphism, papillary architecture, and prominent cell borders. High nuclear grade, necrosis, extensive papillary architecture, raisinoid nuclei, and frequent mitoses were not seen in oncocytomas. Comparing the pathologist and random forest classification, the overall out-of-bag estimate of classification error dropped from 23% to 13% when favor RCC and cannot exclude RCC was combined into 1 category. Resection was performed in 19% (28 cases) with a 94% concordance (100% of favor RCC biopsies and 90% of cannot exclude RCC biopsies confirmed as RCC; 83% of favor oncocytomas confirmed); ablation in 23%; and surveillance in 46%. Follow-up was available in 92% (median follow-up, 33 months) with no adverse outcomes. Renal oncocytic neoplasms comprise a significant subset (16%) of all core biopsies, and the majority (78%) can be classified as favor oncocytoma or favor RCC. Copyright © 2017 Elsevier Inc. All rights reserved.
The best prostate biopsy scheme is dictated by the gland volume: a monocentric study.
Dell'Atti, L
2015-08-01
Accuracy of biopsy scheme depends on different parameters. Prostate-specific antigen (PSA) level and digital rectal examination (DRE) influenced the detection rate and suggested the biopsy scheme to approach each patient. Another parameter is the prostate volume. Sampling accuracy tends to decrease progressively with an increasing prostate volume. We prospectively observed detection cancer rate in suspicious prostate cancer (PCa) and improved by applying a protocol biopsy according to prostate volume (PV). Clinical data and pathological features of these 1356 patients were analysed and included in this study. This protocol is a combined scheme that includes transrectal (TR) 12-core PBx (TR12PBx) for PV ≤ 30 cc, TR 14-core PBx (TR14PBx) for PV > 30 cc but < 60 cc, TR 18-core PBx (TR18PBx) for PV ≥ 60 cc. Out of a total of 1356 patients, in 111 (8.2%) PCa was identified through TR12PBx scheme, in 198 (14.6%) through TR14PBx scheme and in 253 (18.6%) through TR18PBx scheme. The PCa detection rate was increased by 44% by adding two TZ cores (TR14PBx scheme). The TR18PBx scheme increased this rate by 21.7% vs. TR14PBx scheme. The diagnostic yield offered by TR18PBx was statistically significant compared to the detection rate offered by the TR14PBx scheme (p < 0.003). The biopsy Gleason score and the percentage of core involvement were comparable between PCa detected by the TR14PBx scheme diagnostic yield and those detected by the TR18PBx scheme (p = 0.362). The only PV parameter, in our opinion, can be significant in choosing the best biopsy scheme to approach in a first setting of biopsies increasing PCa detection rate.
Nearly Seamless Vacuum-Insulated Boxes
NASA Technical Reports Server (NTRS)
Stepanian, Christopher J.; Ou, Danny; Hu, Xiangjun
2010-01-01
A design concept, and a fabrication process that would implement the design concept, have been proposed for nearly seamless vacuum-insulated boxes that could be the main structural components of a variety of controlled-temperature containers, including common household refrigerators and insulating containers for shipping foods. In a typical case, a vacuum-insulated box would be shaped like a rectangular parallelepiped conventional refrigerator box having five fully closed sides and a hinged door on the sixth side. Although it is possible to construct the five-closed-side portion of the box as an assembly of five unitary vacuum-insulated panels, it is not desirable to do so because the relatively high thermal conductances of the seams between the panels would contribute significant amounts of heat leakage, relative to the leakage through the panels themselves. In contrast, the proposal would make it possible to reduce heat leakage by constructing the five-closed-side portion of the box plus the stationary portion (if any) of the sixth side as a single, seamless unit; the only remaining seam would be the edge seal around the door. The basic cross-sectional configuration of each side of a vacuum-insulated box according to the proposal would be that of a conventional vacuum-insulated panel: a low-density, porous core material filling a partially evacuated space between face sheets. However, neither the face sheets nor the core would be conventional. The face sheets would be opposite sides of a vacuum bag. The core material would be a flexible polymer-modified silica aerogel of the type described in Silica/Polymer and Silica/Polymer/Fiber Composite Aero - gels (MSC-23736) in this issue of NASA Tech Briefs. As noted in that article, the stiffness of this core material against compression is greater than that of prior aerogels. This is an important advantage because it translates to greater retention of thickness and, hence, of insulation performance when pressure is applied across the thickness, in particular, when the space between the face sheets is evacuated, causing the core material to be squeezed between the face sheets by atmospheric pressure. Fabrication of a typical vacuum-insulated box according to the proposal would begin with fabrication of a cross-shaped polymer-modified aerogel blanket. The dimensions of the cross would be chosen so that (1) the central rectangular portion of the cross would form the core for the back of the box and (2) the arms of the cross could be folded 90 from the back plane to form the cores of the adjacent four sides of the box. Optionally, the blanket could include tabs for joining the folded sides of the blanket along mating edges and tabs that could serve as hinges for the door. Vacuum bags in the form of similar five-sided boxes would be made of a suitable polymeric film, one bag to fit the outer core surface, the other to fit the inner core surface. By use of commercially available film-sealing equipment, these box-shaped bags would be seamed together to form a single vacuum bag encasing the box-shaped core. Also, a one-way valve would be sealed to the bag. Through this valve, the interior of the bag would be evacuated to a pressure between 1 and 10 torr (approximately between 0.13 and 1.3 kPa). The polymer-modified aerogel core material is known to perform well as a thermal insulator in such a partial vacuum.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Martin, Peter R., E-mail: pmarti46@uwo.ca; Cool, Derek W.; Romagnoli, Cesare
2014-07-15
Purpose: Magnetic resonance imaging (MRI)-targeted, 3D transrectal ultrasound (TRUS)-guided “fusion” prostate biopsy intends to reduce the ∼23% false negative rate of clinical two-dimensional TRUS-guided sextant biopsy. Although it has been reported to double the positive yield, MRI-targeted biopsies continue to yield false negatives. Therefore, the authors propose to investigate how biopsy system needle delivery error affects the probability of sampling each tumor, by accounting for uncertainties due to guidance system error, image registration error, and irregular tumor shapes. Methods: T2-weighted, dynamic contrast-enhanced T1-weighted, and diffusion-weighted prostate MRI and 3D TRUS images were obtained from 49 patients. A radiologist and radiologymore » resident contoured 81 suspicious regions, yielding 3D tumor surfaces that were registered to the 3D TRUS images using an iterative closest point prostate surface-based method to yield 3D binary images of the suspicious regions in the TRUS context. The probabilityP of obtaining a sample of tumor tissue in one biopsy core was calculated by integrating a 3D Gaussian distribution over each suspicious region domain. Next, the authors performed an exhaustive search to determine the maximum root mean squared error (RMSE, in mm) of a biopsy system that gives P ≥ 95% for each tumor sample, and then repeated this procedure for equal-volume spheres corresponding to each tumor sample. Finally, the authors investigated the effect of probe-axis-direction error on measured tumor burden by studying the relationship between the error and estimated percentage of core involvement. Results: Given a 3.5 mm RMSE for contemporary fusion biopsy systems,P ≥ 95% for 21 out of 81 tumors. The authors determined that for a biopsy system with 3.5 mm RMSE, one cannot expect to sample tumors of approximately 1 cm{sup 3} or smaller with 95% probability with only one biopsy core. The predicted maximum RMSE giving P ≥ 95% for each tumor was consistently greater when using spherical tumor shapes as opposed to no shape assumption. However, an assumption of spherical tumor shape for RMSE = 3.5 mm led to a mean overestimation of tumor sampling probabilities of 3%, implying that assuming spherical tumor shape may be reasonable for many prostate tumors. The authors also determined that a biopsy system would need to have a RMS needle delivery error of no more than 1.6 mm in order to sample 95% of tumors with one core. The authors’ experiments also indicated that the effect of axial-direction error on the measured tumor burden was mitigated by the 18 mm core length at 3.5 mm RMSE. Conclusions: For biopsy systems with RMSE ≥ 3.5 mm, more than one biopsy core must be taken from the majority of tumors to achieveP ≥ 95%. These observations support the authors’ perspective that some tumors of clinically significant sizes may require more than one biopsy attempt in order to be sampled during the first biopsy session. This motivates the authors’ ongoing development of an approach to optimize biopsy plans with the aim of achieving a desired probability of obtaining a sample from each tumor, while minimizing the number of biopsies. Optimized planning of within-tumor targets for MRI-3D TRUS fusion biopsy could support earlier diagnosis of prostate cancer while it remains localized to the gland and curable.« less
Flexural Fatigue Response of Repaired S2-Glass/Vinyl Ester Composites
2009-08-01
of Mechanical Engineering & Applied Mechanics, North Dakota State University, Fargo, ND 58105 14. ABSTRACT Vacuum-assisted resin transfer molding ...Introduction 1 2. Vacuum-Assisted Resin Transfer Molding 2 3. Repair Strategies 2 4. Processing and Repairing Laminates 4 5. Experimental 4 5.1 Set 1...vacuum-assisted resin transfer molding (VARTM) (2), performance evaluations have assumed increasing importance due to the lack of historical databases on
Prostate needle biopsy processing: a survey of laboratory practice across Europe.
Varma, Murali; Berney, Daniel M; Algaba, Ferran; Camparo, Philippe; Compérat, Eva; Griffiths, David F R; Kristiansen, Glen; Lopez-Beltran, Antonio; Montironi, Rodolfo; Egevad, Lars
2013-02-01
To determine the degree of variation in the handling of prostate needle biopsies (PBNx) in laboratories across Europe. A web based survey was emailed to members of the European Network of Uropathology and the British Association of Urological Pathologists. Responses were received from 241 laboratories in 15 countries. PNBx were generally taken by urologists (93.8%) or radiologists (23.7%) but in 8.7% were also taken by non-medical personnel such as radiographers, nurses or biomedical assistants. Of the responding laboratories, 40.8% received cores in separate containers, 42.3% processed one core/block, 54.2% examined three levels/block, 49.4% examined one H&E section/level and 56.1% retained spare sections for potential immunohistochemistry. Of the laboratories, 40.9% retained unstained spares for over a year while 36.2% discarded spares within 1 month of reporting. Only two (0.8%) respondents routinely performed immunohistochemistry on all PNBx. There were differences in laboratory practice between the UK and the rest of Europe (RE). Procurement of PNBx by non-medical personnel was more common in the UK. RE laboratories more commonly received each core in a separate container, processed one core/block, examined fewer levels/block and examined more H&E sections/level. RE laboratories also retained spares for potential immunohistochemistry less often and for shorter periods. Use of p63 as the sole basal cell marker was more common in RE. There are marked differences in procurement, handling and processing of PNBx in laboratories across Europe. This data can help the development of best practice guidelines.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Kroeze, Stephanie G. C.; Huisman, Merel; Verkooijen, Helena M.
2012-06-15
Introduction: Three-dimensional (3D) real-time fluoroscopy cone beam CT is a promising new technique for image-guided biopsy of solid tumors. We evaluated the technical feasibility, diagnostic accuracy, and complications of this technique for guidance of large-core needle biopsy in patients with suspicious renal masses. Methods: Thirteen patients with 13 suspicious renal masses underwent large-core needle biopsy under 3D real-time fluoroscopy cone beam CT guidance. Imaging acquisition and subsequent 3D reconstruction was done by a mobile flat-panel detector (FD) C-arm system to plan the needle path. Large-core needle biopsies were taken by the interventional radiologist. Technical success, accuracy, and safety were evaluatedmore » according to the Innovation, Development, Exploration, Assessment, Long-term study (IDEAL) recommendations. Results: Median tumor size was 2.6 (range, 1.0-14.0) cm. In ten (77%) patients, the histological diagnosis corresponded to the imaging findings: five were malignancies, five benign lesions. Technical feasibility was 77% (10/13); in three patients biopsy results were inconclusive. The lesion size of these three patients was <2.5 cm. One patient developed a minor complication. Median follow-up was 16.0 (range, 6.4-19.8) months. Conclusions: 3D real-time fluoroscopy cone beam CT-guided biopsy of renal masses is feasible and safe. However, these first results suggest that diagnostic accuracy may be limited in patients with renal masses <2.5 cm.« less
Loch, Tillmann
2007-08-01
This study was designed to compare the diagnostic yield of computerized transrectal ultrasound (C-TRUS) guided biopsies in the detection of prostate cancer in a group of men with a history of multiple systematic random biopsies with no prior evidence of prostate cancer. The question was asked: Can we detect cancer by C-TRUS that has been overlooked by multiple systematic biopsies? The entrance criteria for this study were prior negative systematic random biopsies regardless of number of biopsy sessions or number of individual biopsy cores. Serial static TRUS images were evaluated by C-TRUS, which assessed signal information independent of visual gray scale. Five C-TRUS algorithms were utilized to evaluate the information of the ultrasound signal. Interpretation of the results were documented and the most suspicious regions marked by C-TRUS were biopsied by guiding the needle to the marked location. Five hundred and forty men were biopsied because of an elevated PSA or abnormal digital rectal exam. 132 had a history of prior negative systematic random biopsies (1-7 sessions, median: 2 and between 6 and 72 individual prostate biopsies, median: 12 cores). Additionally, a diagnostic TUR-P of the prostate with benign result was performed in four patients. The PSA ranged from 3.1-36 ng/ml with a median of 9.01 ng/ml. The prostate volume ranged from 6-203 ml with a median of 42 ml. Of the 132 patients with prior negative systematic random biopsies, cancer was found in 66 (50%) by C-TRUS targeted biopsies. In this group the median number of negative biopsy sessions was two and a median of 12 biopsy cores were performed. From literature we would expect a cancer detection rate in this group with systematic biopsies of approximately 7%. We only found five carcinomas with a Gleason Score (GS) of 5, 25 with GS 6, 22 with GS 7, 8 with GS 8 and even 7 with GS 9. The results of this prospective clinical trail indicates that the additional use of the C-TRUS identifies clinical significant cancerous lesions that could not been visualized or detected by systematic random biopsies in a very high percentage. In addition, the results of the study support the efforts to search for strategies that utilize expertise and refinement of imaging modalities rather than elevating the number of random biopsies (f.e. 141 cores in one session) in the detection of prostate cancer.
Diagnostic performance and safety of a three-dimensional 14-core systematic biopsy method.
Takeshita, Hideki; Kawakami, Satoru; Numao, Noboru; Sakura, Mizuaki; Tatokoro, Manabu; Yamamoto, Shinya; Kijima, Toshiki; Komai, Yoshinobu; Saito, Kazutaka; Koga, Fumitaka; Fujii, Yasuhisa; Fukui, Iwao; Kihara, Kazunori
2015-03-01
To investigate the diagnostic performance and safety of a three-dimensional 14-core biopsy (3D14PBx) method, which is a combination of the transrectal six-core and transperineal eight-core biopsy methods. Between December 2005 and August 2010, 1103 men underwent 3D14PBx at our institutions and were analysed prospectively. Biopsy criteria included a PSA level of 2.5-20 ng/mL or abnormal digital rectal examination (DRE) findings, or both. The primary endpoint of the study was diagnostic performance and the secondary endpoint was safety. We applied recursive partitioning to the entire study cohort to delineate the unique contribution of each sampling site to overall and clinically significant cancer detection. Prostate cancer was detected in 503 of the 1103 patients (45.6%). Age, family history of prostate cancer, DRE, PSA, percentage of free PSA and prostate volume were associated with the positive biopsy results significantly and independently. Of the 503 cancers detected, 39 (7.8%) were clinically locally advanced (≥cT3a), 348 (69%) had a biopsy Gleason score (GS) of ≥7, and 463 (92%) met the definition of biopsy-based significant cancer. Recursive partitioning analysis showed that each sampling site contributed uniquely to both the overall and the biopsy-based significant cancer detection rate of the 3D14PBx method. The overall cancer-positive rate of each sampling site ranged from 14.5% in the transrectal far lateral base to 22.8% in the transrectal far lateral apex. As of August 2010, 210 patients (42%) had undergone radical prostatectomy, of whom 55 (26%) were found to have pathologically non-organ-confined disease, 174 (83%) had prostatectomy GS ≥7 and 185 (88%) met the definition of prostatectomy-based significant cancer. This is the first prospective analysis of the diagnostic performance of an extended biopsy method, which is a simplified version of the somewhat redundant super-extended three-dimensional 26-core biopsy. As expected, each sampling site uniquely contributed not only to overall cancer detection, but also to significant cancer detection. 3D14PBx is a feasible systematic biopsy method in men with PSA <20 ng/mL. © 2014 The Authors. BJU International © 2014 BJU International.
Digital mammography: more microcalcifications, more columnar cell lesions without atypia.
Verschuur-Maes, Anoek H J; van Gils, Carla H; van den Bosch, Maurice A A J; De Bruin, Peter C; van Diest, Paul J
2011-09-01
The incidence of columnar cell lesions in breast core needle biopsies since full-field digital mammography in comparison with screen-filmed mammography was analyzed. As tiny microcalcifications characterize columnar cell lesions at mammography, we hypothesized that more columnar cell lesions are diagnosed since full-field digital mammography due to its higher sensitivity for microcalcifications. In all, 3437 breast core needle biopsies performed in three hospitals and resulting from in total 55 159 mammographies were revised: 1424 taken in the screen-filmed mammography and 2013 in the full-field digital mammography period. Between the screen-filmed mammography and full-field digital mammography periods, we compared the proportion of mammographies that led to core needle biopsies, the mammographic indication for core needle biopsies (density, microcalcifications, or both) and the proportion of columnar cell lesions with or without atypia. The columnar cell lesions were graded according to Schnitt, and we included atypical ductal hyperplasia arising in the context of columnar cell lesions. Proportions were compared using χ(2) tests and prevalence ratios were adjusted for age and hospital. We found that more core needle biopsies per mammogram were taken in the full-field digital mammography period (7.6%) compared with the screen-filmed mammography period (5.0%, P<0.0001). Microcalcifications were more often diagnosed with full-field digital mammography than with screen-filmed mammography (adjusted prevalence ratio: 1.14, confidence interval 95%: 1.01-1.28). Core needle biopsies from the full-field digital mammography era showed more columnar cell lesions (10.8%) than those from the screen-filmed mammography era (4.9%; adjusted prevalence ratio: 1.93, confidence interval 95%: 1.48-2.51), particularly due to more columnar cell lesions without atypia (8.2% respectively 2.8%) while the proportion of columnar cell lesions with atypia remained nearly constant (2.0 vs 2.6%). In conclusion, since the implementation of full-field digital mammography, more microcalcifications are seen at mammography, more often resulting in core needle biopsies, which especially yields more columnar cell lesions without atypia.
Delgado Oliva, F; Arlandis Guzman, S; Bonillo García, M; Broseta Rico, E; Boronat Tormo, F
2016-10-01
To evaluate the diagnostic performance of gray scale transrectal ultrasound-B-mode US (BMUS), power Doppler (PDUS), and sonographic contrast (CEUS) in early imaging-based diagnosis of localized prostate cancer (PCa) and to compare the diagnostic profitability of randomized biopsy (RB), US-targeted prostate biopsy by means of PDUS and CEUS. A single-center, prospective, transversal, epidemiological study was conducted from January 2010 to January 2014. We consecutively included patients who an imaging study of the prostate with BMUS, PDUS, and CEUS was performed, followed by prostate biopsy due to clinical suspicion of prostate cancer (PSA 4-20ng/mL and/or rectal exam suggestive of malignancy). The diagnostic performance of BMUS, PDUS, and CEUS was determined by calculating the Sensitivity (S), Specificity (Sp), Predictive values (PV), and diagnostic odds ratio (OR) of the diagnosis tests and, for these variables, in the population general and based on their clinical stage according to rectal exam (cT1 and cT2). PCa detection rates determined by means of a randomized 10-core biopsy scheme were compared with detection rates of CEUS-targeted (SonoVue) 2-core biopsies. Of the initial 984 patients, US contrast SonoVue was administered to 179 (18.2%). The PCa detection rate by organ of BMUS/PDUS in the global population was 38% versus 43% in the subpopulation with CEUS. The mean age of the patients was 64.3±7.01years (95% CI, 63.75-64.70); mean total PSA was 8.9±3.61ng/mL (95% CI, 8.67-9.13) and the mean prostate volume was 56.2±29cc (95% CI, 54.2-58.1). The detection rate by organ of targeted biopsy with BMUS, PDUS, and CEUS were as follows: Global population (10.6, 8.2, 24.5%), stage cT1 (5.6, 4.2, 16.4%), and stage cT2 (32.4, 22.3, 43.5%). Comparing the detection rates of the CEUS-targeted biopsy and randomized biopsy, the following results were obtained: Global population (24.5% vs. 41.8%), stage cT1 (16% vs. 35%), and stage cT2 (43.5% vs. 66.6%), with a p value<0.05. Following the "core-by-core" analysis, the detection rates by core of CEUS-targeted biopsy versus randomized biopsy were: Global population (16% vs. 13%), stage cT1 (30.3% vs. 28%), and stage cT2 (48% vs. 37%), with a p value>0.05. The NNT for CEUS-targeted biopsy was 83.3. The low sensitivity, specificity, positive predictive and negative predictive values of gray scale-B-mode, PDUS and CEUS represent scant diagnostic performance of these variables in prostate cancer detection. Prostate cancer detection rates yielded by randomized biopsy were superior than the detection rate of targeted biopsy using B-mode, PDUS and CEUS; as a result, randomized biopsy versus CEUS-targeted biopsies cannot be excluded from biopsy strategy plans for the diagnosis of prostate cancer. Copyright © 2016 Elsevier Ireland Ltd. All rights reserved.
Anandasabapathy, Sharmila; Sontag, Stephen; Graham, David Y; Frist, Stephen; Bratton, Joan; Harpaz, Noam; Waye, Jerome D
2011-03-01
Barrett's epithelial dysplasia, the direct precursor to esophageal adenocarcinoma, is often unapparent and frequently missed during surveillance of Barrett's esophagus with four-quadrant forceps biopsy protocol. To determine whether the detection of dysplasia is improved by adding computer-assisted brush biopsy (EndoCDx©) to four-quadrant biopsy protocol. Patients with a history of Barrett's esophagus with dysplasia scheduled for endoscopic surveillance were recruited from four academic medical centers. Patients underwent brush biopsy followed by four-quadrant biopsy every 1-2 cm. The results from brush and forceps biopsy were reviewed independently by pathologists blinded to the other's results. Among 151 patients enrolled (124 men, 27 women; mean age: 65), 117 (77.5%) had forceps and brush-biopsy specimens adequate for interpretation. The mean number of forceps biopsies was 11.9 (median 10, range 2-40) and brush biopsies was 2.0 (median 2, range 1-4). The overall yield of forceps alone was 25.2% (n = 38). Brush biopsy added an additional 16 positive cases increasing the yield of dysplasia detection by 42% (95% CI: 20.7-72.7). The number needed to test (NNT) to detect one additional case of dysplasia was 9.4 (95% CI: 6.4-17.7). There were no significant differences in results among different centers, between standard versus jumbo forceps, or between forceps biopsies taken every 1 cm versus every 2 cm. These data suggest that computer-assisted brush biopsy is a useful adjunct to standard endoscopic surveillance regimens for the identification of dysplasia in Barrett's esophagus.
Yamaguchi, Rin; Tanaka, Maki; Tse, Gary M; Yamaguchi, Miki; Terasaki, Hiroshi; Nomura, Yoriko; Takenaka, Miki; Naito, Yoshiki; Akiba, Jun; Yano, Hirohisa
2014-03-01
A prominent fibrovascular stromal core is one of the widely accepted histological features of breast papillomas, but some papillary carcinomas also show such broad fibrovascular cores, leading to confusion in diagnosis, particularly in needle biopsy specimens. We investigated the histological characteristics of papillary lesions, focusing on broad fibrovascular cores and their relationship with the architectural patterns. Among 185 cases of needle biopsies of papillomas and papillary carcinomas, the number of cases with broad fibrovascular cores in each group was compared. The broad fibrovascular core density in the subsequently resected specimens was evaluated and compared between papillary predominant pattern (papillary structures >80% of tumours) and mixed pattern (papillary, solid, cribriform and others) within the lesions. Significantly more papillary carcinomas than papillomas and B3 atypical papillary lesions had broad fibrovascular cores (p=0.0091 and p=0.0164, respectively). The papillary predominant pattern was more prominent in carcinomas than in papillomas in the needle biopsies (p=0.048) and showed the same tendency in the resections (p=0.058). The broad fibrovascular core density was significantly lower in the 18 papillomas than in the 37 papillary carcinomas (p=0.0079) and was not significantly different between the papillary predominant and mixed patterns in carcinomas and papillomas. Broad fibrovascular cores in mammary papillary lesions are not specific for papillomas, as they are also present focally in papillary carcinomas. As the frequency of papillary carcinoma with broad fibrovascular cores is relatively high, caution in diagnosis has to be exercised, especially in needle biopsy specimens.
Yılmaz, Hasan; Yavuz, Ufuk; Üstüner, Murat; Çiftçi, Seyfettin; Yaşar, Hikmet; Müezzinoğlu, Bahar; Uslubaş, Ali Kemal; Dillioğlugil, Özdal
2017-01-01
Objective Only a few papers in the literature aimed to evaluate biopsy core lengths. Additionally, studies evaluated the core length with different approaches. We aimed to determine whether prostate cancer (PCa) detection is affected from core lengths according to three different approaches in a large standard cohort and compare our cut-off values with the published cut-offs. Material and methods We retrospectively analyzed 1,523 initial consecutive transrectal ultrasound-guided 12-core prostate biopsies. Biopsies were evaluated with respect to total core length (total length of each patients’ core) average core length (total core length divided by total number of cores in each patient), and mean core length (mean length of all cores pooled), and compared our cut-off values with the published cut-offs. The prostate volumes were categorized into four groups (<30, 30–59.99, 60–119.99, ≥120 cm3) and PCa detection rates in these categories were examined. Results PCa was found in 41.5% patients. There was no difference between benign and malignant mean core lengths of the pooled cores (p>0.05). Total core length and average core length were not significantly associated with PCa in multivariate logistic regression analyses (p>0.05). The core lengths (mean, average and total core lengths) increased (p<0.001) and PCa rates decreased (p<0.001) steadily with increasing prostate volume categories. PCa percentages decreased in all categories above the utilized cut-offs for mean (p>0.05), average (p<0.05), and total core lengths (p>0.05). Conclusion There was no difference between mean core lengths of benign and malignant cores. Total core length and average core length were not significantly associated with PCa. Contrary to the cut-offs used for mean and average core lengths in the published studies, PCa rates decrease as these core lengths increase. Larger studies are necessary for the determination and acceptance of accurate cut-offs. PMID:28861301
DOE Office of Scientific and Technical Information (OSTI.GOV)
Rivera-Sanfeliz, Gerant, E-mail: gerantrivera@ucsd.edu; Kinney, Thomas B.; Rose, Steven C.
2005-06-15
Purpose: To describe our experience with ultrasound (US)-guided percutaneous liver biopsies using the INRAD 18G Express core needle biopsy system.Methods: One hundred and fifty-four consecutive percutaneous core liver biopsy procedures were performed in 153 men in a single institution over 37 months. The medical charts, pathology reports, and radiology files were retrospectively reviewed. The number of needle passes, type of guidance, change in hematocrit level, and adequacy of specimens for histologic analysis were evaluated.Results: All biopsies were performed for histologic staging of chronic liver diseases. The majority of patients had hepatitis C (134/153, 90.2%). All patients were discharged to homemore » after 4 hr of postprocedural observation. In 145 of 154 (94%) biopsies, a single needle pass was sufficient for diagnosis. US guidance was utilized in all but one of the procedures (153/154, 99.4%). The mean hematocrit decrease was 1.2% (44.1-42.9%). Pain requiring narcotic analgesia, the most frequent complication, occurred in 28 of 154 procedures (18.2%). No major complications occurred. The specimens were diagnostic in 152 of 154 procedures (98.7%).Conclusions: Single-pass percutaneous US-guided liver biopsy with the INRAD 18G Express core needle biopsy system is safe and provides definitive pathologic diagnosis of chronic liver disease. It can be performed on an outpatient basis. Routine post-biopsy monitoring of hematocrit level in stable, asymptomatic patients is probably not warranted.« less
21. Engine identified as a 'single cylinder vacuum assist engine ...
21. Engine identified as a 'single cylinder vacuum assist engine for Tod tandem compound engine' showing compressor. - Carnegie Steel-Ohio Works, Steam Engines, 912 Salt Springs Road, Youngstown, Mahoning County, OH
Pugliese, Novella; Di Perna, M; Cozzolino, I; Ciancia, G; Pettinato, G; Zeppa, P; Varone, V; Masone, S; Cerchione, C; Della Pepa, R; Simeone, L; Giordano, C; Martinelli, V; Salvatore, C; Pane, F; Picardi, M
2017-04-01
The sensitivity of lymph node core-needle biopsy under imaging guidance requires validation. We employed power Doppler ultrasonography (PDUS) to select the lymph node most suspected of malignancy and to histologically characterize it through the use of large cutting needle. Institutional review board approval and informed consent were obtained for this randomized clinical trial. In a single center between 1 January 2009 and 31 December 2015, patients with lymph node enlargement suspected for lymphoma were randomly assigned (1:1) to biopsy with either standard surgery or PDUS-guided 16-gauge modified Menghini needle. The primary endpoint was the superiority of sensitivity for the diagnosis of malignancy for core-needle cutting biopsy (CNCB). Secondary endpoints were times to biopsy, complications, and costs. A total of 376 patients were randomized into the two arms and received allocated biopsy. However, four patients undergoing CNCB were excluded for inadequate samples; thus, 372 patients were analyzed. Sensitivity for the detection of malignancy was significantly better for PDUS-guided CNCB [98.8%; 95% confidence interval (CI), 95.9-99.9] than standard biopsy (88.7%; 95% CI, 82.9-93; P < 0.001). For all secondary endpoints, the comparison was significantly disadvantageous for conventional approach. In particular, estimated cost per biopsy performed with standard surgery was 24-fold higher compared with that performed with CNCB. The presence of satellite enlarged reactive and/or necrotic lymph nodes may impair the success of an open surgical biopsy (OSB). PDUS and CNCB with adequate gauge are diagnostic tools that enable effective, safe, fast, and low-cost routine biopsy for patients with suspected lymphoma, avoiding psychological and physical pain of an unnecessary surgical intervention.
[The Diagnostic Value of Pre-Biopsy Magnetic Resonance Imaging (MRI) for Detecting Prostate Cancer].
Mori, Kohei; Miyoshi, Yasuhide; Yoneyama, Shuko; Ishida, Hiroaki; Hattori, Yusuke; Teranishi, Jun-ichi; Kondo, Keiichi; Noguchi, Kazumi
2016-01-01
We examined the value of pre-biopsy magnetic resonance imaging (MRI) for detecting prostate cancer. We analyzed 267 men with prostate-specific antigen (PSA) levels of 3-10 ng/ml who underwent systematic prostate needle biopsy. From April 2009 to March 2011, a total of 98 male patients underwent 16-core prostatic biopsies without pre-biopsy magnetic resonance imaging (MRI) (nonenforcement group). From April 2011 to March 2013, 169 men underwent pre-biopsy MRI [T2-weighted imaging (T2WI) and diffusion-weighted imaging (DWI)] (enforcement group). When MRI findings indicated cancer in the latter group, in addition to the systematic 16-core biopsy one or two targeted biopsies were performed. Patients without suspicious MRI findings underwent only systematic 16-core biopsy. Cancer detection rates in the nonenforcement and enforcement groups were 42.9% (48/92) and 46. 2% (78/169), respectively. The difference did not reach significance (p=0.612). Although the cancer detection rates were 39.4% (41/104) in the MRI-negative group and 56. 9% (37/65) in the MRI-positive group (p=0.039), the sensitivity and specificity for cancer detection by MRI were relatively low: 47.4% and 69.2%, respectively. By receiver-operating curve analysis, the area under the curve for cancer detection by MRI was only 0.583. There were two study limitations. First, the patient sample size was small. Second, it is unclear whether an adequate sample of the suspicious lesion was obtained by biopsy. We thus demonstrated that it might be improper to base a diagnosis solely on pre-biopsy MRI (T2WI and DWI) findings in men with serum PSA levels of 3-10 ng/ml.
Surgical excision of pure flat epithelial atypia identified on core needle breast biopsy.
Prowler, Vanessa L; Joh, Jennifer E; Acs, Geza; Kiluk, John V; Laronga, Christine; Khakpour, Nazanin; Lee, M Catherine
2014-08-01
The biology of flat epithelial atypia (FEA) is still being investigated as its presence becomes more frequent on biopsy specimens. FEA is more commonly associated with malignancy when found in association with ADH, ALH or LCIS. Pure FEA is only upgraded to cancer in 3.2% of patients. Surgical excision of pure FEA found on core needle biopsy results in overtreatment in the vast majority of breast patients and may not be necessary. Copyright © 2014 Elsevier Ltd. All rights reserved.
Fine-needle aspiration cytology of hemangiopericytoma: report of two cases.
Sawh, R N; Lele, S M; Borkowski, J; Ventura, K C; Zaharopoulos, P; Logroño, R
2000-09-01
The fine-needle aspiration biopsy (FNAB) findings in two cases of hemangiopericytoma (HP), arising in the parotid gland and on the inner chest wall, respectively, are reported. Smear preparations in each case showed cytologic features of an undifferentiated spindle-cell neoplasm, whereas a core needle biopsy specimen of the chest wall mass showed a spindle-cell tumor with a "staghorn-like" arrangement of endothelium-lined vascular channels. Immunostains performed on this core biopsy, and on the surgical resection specimens in both cases, showed positive staining of tumor cells for vimentin and CD34, with negative staining for a variety of smooth muscle, epithelial, neural, and neuroendocrine markers. Electron microscopy performed in one case further supported the diagnosis of HP. With adequate sampling and appropriate use of ancillary studies, a diagnosis of HP can be reliably suggested on the basis of FNAB and core biopsy of a soft-tissue mass. Copyright 2000 Wiley-Liss, Inc.
20. Engine identified as a 'single cylinder vacuum assist engine ...
20. Engine identified as a 'single cylinder vacuum assist engine for the Tod tandem compound engine' showing crank end. - Carnegie Steel-Ohio Works, Steam Engines, 912 Salt Springs Road, Youngstown, Mahoning County, OH
19. Engine identified as a single cylinder vacuum assist engine ...
19. Engine identified as a single cylinder vacuum assist engine for the Filer and Stowell 15-inch continuous mill. - Carnegie Steel-Ohio Works, Steam Engines, 912 Salt Springs Road, Youngstown, Mahoning County, OH
Is seminal vesiculectomy necessary in all patients with biopsy Gleason score 6?
Gofrit, Ofer N; Zorn, Kevin C; Shikanov, Sergey A; Zagaja, Gregory P; Shalhav, Arieh L
2009-04-01
Radiotherapists are excluding the seminal vesicles (SVs) from their target volume in cases of low-risk prostate cancer. However, these glands are routinely removed in every radical prostatectomy. Dissection of the SVs can damage the pelvic plexus, compromise trigonal, bladder neck, and cavernosal innervation, and contribute to delayed gain of continence and erectile function. In this study we evaluated the oncological benefit of routine removal of the SVs in currently operated patients. A total of 1003 patients (mean age, 59.7 years) with prostate cancer underwent robot-assisted radical prostatectomy between February 2003 and July 2007. Seminal vesicle invasion (SVI) was found in 46 of the operated patients (4.6%). Biopsy Gleason score (BGS), preoperative serum PSA, clinical tumor stage, percent of positive cores, and maximal percentage of cancer in a core had all a significant impact on the risk of SVI. Only 4/634 patients (0.6%) with BGS < or =6 suffered from SVI, as opposed to 42/369 (11.4%) with higher Gleason scores. Seminal vesiculectomy does not benefit more than 99% of the patients with BGS < or =6. Considering the potential neural and vascular damage associated with seminal vesiculectomy, we suggest that routine removal of these glands during radical prostatectomy in these cases is not necessary.
Ouzzane, Adil; Renard-Penna, Raphaele; Marliere, François; Mozer, Pierre; Olivier, Jonathan; Barkatz, Johann; Puech, Philippe; Villers, Arnauld
2015-08-01
Current selection criteria for active surveillance based on systematic biopsy underestimate prostate cancer volume and grade. We investigated the role of additional magnetic resonance imaging targeted biopsy in reclassifying patients eligible for active surveillance based on systematic biopsy. We performed a study at 2 institutions in a total of 281 men with increased prostate specific antigen. All men met certain criteria, including 1) prebiopsy magnetic resonance imaging, 12-core transrectal systematic biopsy and 2 additional magnetic resonance imaging targeted biopsies of lesions suspicious for cancer during the same sequence as systematic biopsy, and 2) eligibility for active surveillance based on systematic biopsy results. Criteria for active surveillance were prostate specific antigen less than 10 ng/ml, no Gleason grade 4/5, 5 mm or less involvement of any biopsy core and 2 or fewer positive systematic biopsy cores. Patient characteristics were compared between reclassified and nonreclassified groups based on magnetic resonance imaging targeted biopsy results. On magnetic resonance imaging 58% of the 281 patients had suspicious lesions. Magnetic resonance imaging targeted biopsy was positive for cancer in 81 of 163 patients (50%). Of 281 patients 28 (10%) were reclassified by magnetic resonance imaging targeted biopsy as ineligible for active surveillance based on Gleason score in 8, cancer length in 20 and Gleason score plus cancer length in 9. Suspicious areas on magnetic resonance imaging were in the anterior part of the prostate in 15 of the 28 men (54%). Reclassified patients had a smaller prostate volume (37 vs 52 cc) and were older (66.5 vs 63 years) than those who were not reclassified (p < 0.05). Magnetic resonance imaging targeted biopsy reclassified 10% of patients who were eligible for active surveillance based on systematic biopsy. Its incorporation into the active surveillance eligibility criteria may decrease the risk of reclassification to higher stages during followup. Copyright © 2015 American Urological Association Education and Research, Inc. Published by Elsevier Inc. All rights reserved.
Hematoma formation during breast core needle biopsy in women taking antithrombotic therapy.
Chetlen, Alison L; Kasales, Claudia; Mack, Julie; Schetter, Susann; Zhu, Junjia
2013-07-01
The purpose of this study was to compare hematoma formation after breast core needle biopsy performed on patients undergoing and those not undergoing concurrent antithrombotic therapy. A prospective assessment of core needle biopsies (stereotactic, ultrasound guided, or MRI guided) performed on patients enrolled between September 2011 and July 2012 formed the basis of this study. Postprocedure mediolateral and craniocaudal mammograms were evaluated for the presence and size of hematomas. Patients were clinically evaluated for complications 24-48 hours after the procedure through telephone call or face-to-face consultation. Needle size, type of biopsy, and presence of hematoma and documented complications were correlated with use of antithrombotic agents (including aspirin, warfarin, clopidogrel, and daily nonsteroidal antiinflammatory medications). No clinically significant hematomas or bleeding complications were found. Eighty-nine of 617 (14.4%) non-clinically significant hematomas were detected on postprocedure mammograms. The probability of development of a non-clinically significant hematoma was 21.6% for patients taking antithrombotics and 13.0% for those not taking antithrombotics. Concurrent antithrombotic therapy and larger needle gauge were significant factors contributing to the probability of hematoma formation. The volume of the hematoma was not related to needle gauge or presence of antithrombotic therapy. No clinically significant hematomas were found. Because there are potential life-threatening risks to stopping antithrombotic therapy before breast biopsy, withholding antithrombotic therapy for core needle breast biopsy is not recommended because the incidence of non-clinically significant hematoma is low.
Tilak, Gaurie; Tuncali, Kemal; Song, Sang-Eun; Tokuda, Junichi; Olubiyi, Olutayo; Fennessy, Fiona; Fedorov, Andriy; Penzkofer, Tobias; Tempany, Clare; Hata, Nobuhiko
2015-07-01
To demonstrate the utility of a robotic needle-guidance template device as compared to a manual template for in-bore 3T transperineal magnetic resonance imaging (MRI)-guided prostate biopsy. This two-arm mixed retrospective-prospective study included 99 cases of targeted transperineal prostate biopsies. The biopsy needles were aimed at suspicious foci noted on multiparametric 3T MRI using manual template (historical control) as compared with a robotic template. The following data were obtained: the accuracy of average and closest needle placement to the focus, histologic yield, percentage of cancer volume in positive core samples, complication rate, and time to complete the procedure. In all, 56 cases were performed using the manual template and 43 cases were performed using the robotic template. The mean accuracy of the best needle placement attempt was higher in the robotic group (2.39 mm) than the manual group (3.71 mm, P < 0.027). The mean core procedure time was shorter in the robotic (90.82 min) than the manual group (100.63 min, P < 0.030). Percentage of cancer volume in positive core samples was higher in the robotic group (P < 0.001). Cancer yields and complication rates were not statistically different between the two subgroups (P = 0.557 and P = 0.172, respectively). The robotic needle-guidance template helps accurate placement of biopsy needles in MRI-guided core biopsy of prostate cancer. © 2014 Wiley Periodicals, Inc.
Guilbert, Marie-Christine; Frost, Elisabeth P; Brock, Jane E; Lester, Susan C
2018-02-24
Papillary endothelial hyperplasia (PEH) is a rare non-neoplastic exuberant organizing hematoma that can closely mimic angiosarcoma due to a resemblance to malignant anastomosing blood vessels. It could be particularly difficult to distinguish PEH from angiosarcoma in breast core needle biopsies. We identified all cases of these lesions diagnosed on core needle biopsy in order to identify clinical, radiologic, and pathologic features that could prove helpful to arrive at the correct diagnosis. Four cases of PEH and 4 cases of angiosarcoma were identified. The mean age at diagnosis was 62 for PEH and 33 for primary angiosarcoma. All cases of PEH formed small masses with circumscribed or lobulated margins by imaging (mean size 0.9 cm). In 3 cases, the masses were difficult or impossible to identify after the biopsy. Angiosarcomas presented as larger masses with ill-defined margins (mean size 2.8 cm) that were unchanged in size after biopsy. PEH was surrounded by adipose tissue, whereas angiosarcoma invaded into fibrous stroma and involved lobules. The pseudopapillary structures of PEH were composed mainly of collagen, and thus, additional histologic stains for fibrin were not helpful for diagnosis. The 4 patients with PEH received no further treatment and are alive and disease-free at 2-11 years of follow-up. In contrast, the patients with angiosarcoma underwent mastectomy and chemotherapy or radiation therapy. Two of the patients with angiosarcoma died 3 years after diagnosis and the other 2 patients are alive without disease at 5 and 6 years. Therefore, distinguishing PEH and angiosarcoma is essential for appropriate management. This is the first series to compare these lesions on core needle biopsy and the first to note important clinical, imaging, and histologic differences that aid in making a diagnosis of PEH with confidence on breast core needle biopsy. © 2018 Wiley Periodicals, Inc.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Vance, Sean M.; Stenmark, Matthew H.; Blas, Kevin
2012-07-01
Purpose: To investigate the prognostic utility of the percentage of cancer volume (PCV) in needle biopsy specimens for prostate cancer patients treated with dose-escalated external beam radiotherapy. Methods and Materials: The outcomes were analyzed for 599 men treated for localized prostate cancer with external beam radiotherapy to a minimal planning target volume dose of 75 Gy (range, 75-79.2). We assessed the effect of PCV and the pretreatment and treatment-related factors on the freedom from biochemical failure, freedom from metastasis, cause-specific survival, and overall survival. Results: The median number of biopsy cores was 7 (interquartile range, 6-12), median PCV was 10%more » (interquartile range, 2.5-25%), and median follow-up was 62 months. The PCV correlated with the National Comprehensive Cancer Network risk group and individual risk features, including T stage, prostate-specific antigen level, Gleason score, and percentage of positive biopsy cores. On log-rank analysis, the PCV stratified by quartile was prognostic for all endpoints, including overall survival. In addition, the PCV was a stronger prognostic factor than the percentage of positive biopsy cores when the two metrics were analyzed together. On multivariate analysis, the PCV predicted a worse outcome for all endpoints, including freedom from biochemical failure, (hazard ratio, 1.9; p = .0035), freedom from metastasis (hazard ratio, 1.7, p = .09), cause-specific survival (hazard ratio, 3.9, p = .014), and overall survival (hazard ratio, 1.8, p = .02). Conclusions: For patients treated with dose-escalated external beam radiotherapy, the volume of cancer in the biopsy specimen adds prognostic value for clinically relevant endpoints, particularly in intermediate- and high-risk patients. Although the PCV determination is more arduous than the percentage of positive biopsy cores, it provides superior risk stratification.« less
Raff, Lester J; Engel, George; Beck, Kenneth R; O'Brien, Andrea S; Bauer, Meagan E
2009-02-01
The elimination or reduction of medical errors has been a main focus of health care enterprises in the United States since the year 2000. Elimination of errors in patient and specimen identification is a key component of this focus and is the number one goal in the Joint Commission's 2008 National Patient Safety Goals Laboratory Services Program. To evaluate the effectiveness of using permanent inks to maintain specimen identity in sequentially submitted prostate needle biopsies. For a 12-month period, a grossing technician stained each prostate core with permanent ink developed for inking of pathology specimens. A different color was used for each patient, with all the prostate cores from all vials for a particular patient inked with the same color. Five colors were used sequentially: green, blue, yellow, orange, and black. The ink was diluted with distilled water to a consistency that allowed application of a thin, uniform coating of ink along the edges of the prostate core. The time required to ink patient specimens comprising different numbers of vials and prostate biopsies was timed. The number and type of inked specimen discrepancies were evaluated. The identified discrepancy rate for prostate biopsy patients was 0.13%. The discrepancy rate in terms of total number of prostate blocks was 0.014%. Diluted inks adhered to biopsy contours throughout tissue processing. The tissue showed no untoward reactions to the inks. Inking did not affect staining (histochemical or immunohistochemical) or pathologic evaluation. On average, inking prostate needle biopsies increases grossing time by 20%. Inking of all prostate core biopsies with colored inks, in sequential order, is an aid in maintaining specimen identity. It is a simple and effective method of addressing Joint Commission patient safety goals by maintaining specimen identity during processing of similar types of gross specimens. This technique may be applicable in other specialty laboratories and high-volume laboratories, where many similar tissue specimens are processed.
Zackrisson, Bjørn; Aus, Gunnar; Bergdahl, Svante; Lilja, Hans; Lodding, Pär; Pihl, Carl-Gustav; Hugosson, Jonas
2004-04-01
We evaluated the significance of focal prostate cancer found in sextant biopsies in men participating in a biennial prostate specific antigen (PSA) based screening program. In 1995, 10000 men 50 to 65 years old were randomized to biennial screening with PSA testing. Sextant biopsies were recommended when total PSA was 3 ng/ml or greater at screening rounds 1 and 2, and 2.54 ng/ml or greater at subsequent screening rounds. Focal cancer was defined as total a core cancer length of less than 3 mm in the biopsy specimen. Low volume cancer was defined as a total tumor volume of less than 0.5 cm in the radical retropubic prostatectomy specimen. The number of men who underwent biopsy and the number of cancers detected in the 5 possible sets of biopsies were 1725 and 402, 706 and 124, 307 and 36, 103 and 9, and 13 and 0, respectively. The risk of detecting focal cancer was 7.9%, 10.2%, 7.5%, 5.8% and 0%, respectively, but the relative ratio (focal-to-all cancers) increased 34%, 58%, 64%, 67% and, not applicable, respectively. In men with a total core cancer length of less than 10 mm there was no correlation between core cancer length and total tumor volume, as measured in the prostatectomy specimen. Two-thirds of men with a total core cancer length of less than 3 mm had a tumor volume of greater than 0.5 cm, while the risk of low volume cancer was less than 5% only in men with a total core cancer length of greater than 10 mm. In a repeat PSA based screening program sextant biopsies are of little or no value for predicting tumor volume.
Lai, Hung-Wen; Wu, Hwa-Koon; Kuo, Shou-Jen; Chen, Shou-Tung; Tseng, Hsin-Shun; Tseng, Ling-Ming; Chen, Dar-Ren
2013-04-01
Core needle biopsy (CNB) was widely used in the diagnosis of ultrasound-detectable breast lesions. We aimed at assessing the diagnostic performance differences between 14- and 16-gauge ultrasound-guided core biopsies. This retrospective study enrolled patients receiving CNB from January 2001 to December 2007. The results of 14- and 16-gauge breast CNBs were compared with pathology reports of open surgical biopsy (OSB). A total of 1024 paired CNB and OSB results were obtained from 1732 CNB procedures in 1630 patients.Those CNB results reached 92.9% sensitivity, 99.7% specificity, 5.96% underestimation, and 94.8% accuracy rates. There was no difference in sensitivity (p=0.17) or specificity (p=0.38) between 14- and 16-gauge needles. However, better overall accuracy (p=0.02), less underestimation (p<0.001), and lower false-negative (p=0.02) rates were found for the 14-gauge CNB. Regarding accuracy and underestimation rates, a 14-gauge needle is preferred to a 16-gauge one in ultrasound-guided biopsies. Copyright © 2012. Published by Elsevier B.V.
3-D Quantitative Dynamic Contrast Ultrasound for Prostate Cancer Localization.
Schalk, Stefan G; Huang, Jing; Li, Jia; Demi, Libertario; Wijkstra, Hessel; Huang, Pintong; Mischi, Massimo
2018-04-01
To investigate quantitative 3-D dynamic contrast-enhanced ultrasound (DCE-US) and, in particular 3-D contrast-ultrasound dispersion imaging (CUDI), for prostate cancer detection and localization, 43 patients referred for 10-12-core systematic biopsy underwent 3-D DCE-US. For each 3-D DCE-US recording, parametric maps of CUDI-based and perfusion-based parameters were computed. The parametric maps were divided in regions, each corresponding to a biopsy core. The obtained parameters were validated per biopsy location and after combining two or more adjacent regions. For CUDI by correlation (r) and for the wash-in time (WIT), a significant difference in parameter values between benign and malignant biopsy cores was found (p < 0.001). In a per-prostate analysis, sensitivity and specificity were 94% and 50% for r, and 53% and 81% for WIT. Based on these results, it can be concluded that quantitative 3-D DCE-US could aid in localizing prostate cancer. Therefore, we recommend follow-up studies to investigate its value for targeting biopsies. Copyright © 2018 World Federation for Ultrasound in Medicine and Biology. Published by Elsevier Inc. All rights reserved.
Haroon, Naveed; Ather, M Hammad; Khan, Salma; Kumar, Pirkash; Salam, Basit
2015-10-01
To compare preprocedure Diclofenac suppository and Xylocaine gel with Xylocaine gel only in patients undergoing transrectal ultrasound (TRUS)-guided biopsy of prostate for pain. It is a randomized controlled trial conducted on patients undergoing TRUS-guided biopsy for clinical or biochemical suspicion of prostate cancer following a written informed consent and Ethics Review Committee approval. Patients were randomized into 2 groups. Group A included those patients who received Diclofenac suppository 2 hours before in combination with 10 mL of 2% Xylocaine gel 5 minutes before biopsy. Group B received Xylocaine gel only. A visual analog scale was used to measure the pain scores at the time of TRUS probe insertion, just after taking biopsy cores and 2 hours after biopsy. A total of 100 patients were recruited in the study with 50 patients each in group A and B. Mean age of group A was 69.1 ± 10 years and 67.3 ± 8.1 years for group B. The mean pain score for group A and B at the time of probe insertion was 0.08 ± 0.27 and 0.34 ± 0.63 (P = .032), immediately after taking biopsy cores was 1.46 ± 1.15 and 4.68 ± 0.77 (P = .000), and 2 hours after biopsy was 0.14 ± 0.45 vs 2.40 ± 0.81 (P = .000), respectively. The mean pain score at the time of TRUS probe insertion, immediately after taking biopsy cores, and 2 hours after biopsy is statistically significantly higher in group B. Copyright © 2015 Elsevier Inc. All rights reserved.
Gurel, Bora; Lucia, M. Scott; Thompson, Ian M.; Goodman, Phyllis J.; Tangen, Catherine M.; Kristal, Alan R.; Parnes, Howard L.; Hoque, Ashraful; Lippman, Scott M.; Sutcliffe, Siobhan; Peskoe, Sarah B.; Drake, Charles G.; Nelson, William G.; De Marzo, Angelo M.; Platz, Elizabeth A.
2014-01-01
Background Chronic inflammation is hypothesized to influence prostate cancer development, although a definitive link has not been established. Methods Prostate cancer cases (N=191) detected on a for-cause (clinically indicated) or end-of-study (protocol directed) biopsy, and frequency-matched controls (N=209), defined as negative for cancer on an end-of-study biopsy, were sampled from the placebo arm of the Prostate Cancer Prevention Trial. Inflammation prevalence and extent in benign areas of biopsy cores were visually assessed using digital images of H&E stained sections. Logistic regression was used to estimate associations. Results 86.2% of cases and 78.2% of controls had at least one biopsy core (of 3 assessed) with inflammation in benign areas, most of which was chronic. Men who had at least one biopsy core with inflammation had 1.78 (95% CI 1.04–3.06) times the odds of prostate cancer compared with men who had zero cores with inflammation. The association was stronger for high-grade disease (Gleason sum 7–10, N=94; odds ratio [OR]=2.24, 95% CI 1.06–4.71). These patterns were present when restricting to cases and controls in whom intraprostatic inflammation was the least likely to have influenced biopsy recommendation because their PSA was low (<2 ng/mL at biopsy). Conclusion Inflammation, most of which was chronic, was common in benign prostate tissue, and was positively associated with prostate cancer, especially high-grade. The association did not appear to be due to detection bias. Impact This study supports an etiologic link between inflammation and prostate carcinogenesis, and suggests an avenue for prevention by mitigating intraprostatic inflammation. PMID:24748218
21 CFR 884.1175 - Endometrial suction curette and accessories.
Code of Federal Regulations, 2011 CFR
2011-04-01
... uterus by scraping and vacuum suction. This device is used to obtain tissue for biopsy or for menstrual extraction. This generic type of device may include catheters, syringes, and tissue filters or traps. (b...
21 CFR 884.1175 - Endometrial suction curette and accessories.
Code of Federal Regulations, 2010 CFR
2010-04-01
... uterus by scraping and vacuum suction. This device is used to obtain tissue for biopsy or for menstrual extraction. This generic type of device may include catheters, syringes, and tissue filters or traps. (b...
Prostate biopsies assisted by comanipulated probe-holder: first in man.
Vitrani, Marie-Aude; Baumann, Michael; Reversat, David; Morel, Guillaume; Moreau-Gaudry, Alexandre; Mozer, Pierre
2016-06-01
A comanipulator for assisting endorectal prostate biopsies is evaluated through a first-in-man clinical trial. This lightweight system, based on conventional robotic components, possesses six degrees of freedom. It uses three electric motors and three brakes. It features a free mode, where its low friction and inertia allow for natural manipulation of the probe and a locked mode, exhibiting both a very low stiffness and a high steady-state precision. Clinical trials focusing on the free mode and the locked mode of the robot are presented. The objective was to evaluate the practical usability and performance of the robot during clinical procedures. A research protocol for a prospective randomized clinical trial has been designed. Its specific goal was to compare the accuracy of biopsies performed with and without the assistance of the comanipulator. The accuracy is compared between biopsies performed with and without the assistance of the comanipulator, across the 10 first patients included in the trial. Results show a statistically significant increase in the precision.
Hari, Smriti; Kumari, Swati; Srivastava, Anurag; Thulkar, Sanjay; Mathur, Sandeep; Veedu, Prasad Thotton
2016-01-01
Background & objectives: Biopsy of palpable breast masses can be performed manually by palpation guidance or under imaging guidance. Based on retrospective studies, image guided biopsy is considered more accurate than palpation guided breast biopsy; however, these techniques have not been compared prospectively. We conducted this prospective study to verify the superiority and determine the size of beneficial effect of image guided biopsy over palpation guided biopsy. Methods: Over a period of 18 months, 36 patients each with palpable breast masses were randomized into palpation guided and image guided breast biopsy arms. Ultrasound was used for image guidance in 33 patients and mammographic (stereotactic) guidance in three patients. All biopsies were performed using 14 gauge automated core biopsy needles. Inconclusive, suspicious or imaging-histologic discordant biopsies were repeated. Results: Malignancy was found in 30 of 36 women in palpation guided biopsy arm and 27 of 36 women in image guided biopsy arm. Palpation guided biopsy had sensitivity, specificity, positive predictive value (PPV) and negative predictive value (NPV) of 46.7, 100, 100, 27.3 per cent, respectively, for diagnosing breast cancer. Nineteen of 36 women (52.8%) required repeat biopsy because of inadequate samples (7 of 19), suspicious findings (2 of 19) or imaging-histologic discordance (10 of 19). On repeat biopsy, malignancy was found in all cases of imaging-histologic discordance. Image guided biopsy had 96.3 per cent sensitivity and 100 per cent specificity. There was no case of inadequate sample or imaging-histologic discordance with image guided biopsy. Interpretation & conclusions: Our results showed that in palpable breast masses, image guided biopsy was superior to palpation guided biopsy in terms of sensitivity, false negative rate and repeat biopsy rates. PMID:27488003
Advances in Breast Cancer Therapy
2012-09-01
cancer diagnosed by core needle biopsy will be eligible for this study. Additional tumor specimens will be obtained prior to the start of...chemotherapy via core needle biopsies to be used for the ex vivo chemoresponse assay and tumor genomic analysis (gene expression), respectively. All...AD_________________ Award Number: W81XWH-06-2-0021 TITLE: Advances in Breast Cancer Therapy
Photo-thermal processing of semiconductor fibers and thin films
NASA Astrophysics Data System (ADS)
Gupta, Nishant
Furnace processing and rapid thermal processing (RTP) have been an integral part of several processing steps in semiconductor manufacturing. The performance of RTP techniques can be improved many times by exploiting quantum photo-effects of UV and vacuum ultraviolet (VUV) photons in thermal processing and this technique is known as rapid photo-thermal processing (RPP). As compared to furnace processing and RTP, RPP provides higher diffusion coefficient, lower stress and lower microscopic defects. In this work, a custom designed automated photo assisted processing system was built from individual parts and an incoherent light source. This photo-assisted processing system is used to anneal silica clad silicon fibers and deposit thin-films. To the best of our knowledge, incoherent light source based rapid photo-thermal processing (RPP) was used for the first time to anneal glass-clad silicon core optical fibers. X-ray diffraction examination, Raman spectroscopy and electrical measurements showed a considerable enhancement of structural and crystalline properties of RPP treated silicon fibers. Photons in UV and vacuum ultraviolet (VUV) regions play a very important role in improving the bulk and carrier transport properties of RPP-treated silicon optical fibers, and the resultant annealing permits a path forward to in situ enhancement of the structure and properties of these new crystalline core optical fibers. To explore further applications of RPP, thin-films of Calcium Copper Titanate (CaCu3Ti4O12) or CCTO and Copper (I) Oxide (Cu2O) were also deposited using photo-assisted metal-organic chemical vapor deposition (MOCVD) on Si/SiO2 and n-Si substrate respectively. CCTO is one of the most researched giant dielectric constant materials in recent years. The given photo-assisted MOCVD approach provided polycrystalline CCTO growth on a SiO2 surface with grain sizes as large as 410 nm. Copper (I) oxide (Cu2O) is a direct band gap semiconductor with p-type conductivity and is a potential candidate for multi-junction solar cells. X-ray diffraction study revealed a preferred orientation, as (200) oriented crystals of Cu2O are grown on both substrates. Also, electrical characterization of Cu2O/n-Si devices showed the lowest saturation current density of 1.5x10-12 A/cm 2 at zero bias. As a result, photo-assisted thermal processing has the potential of making the process more effective with enhanced device performance.
Catteau, Xavier; Simon, Philippe; Noël, Jean-Christophe
2012-04-15
15±30% of malignancies detected through screening programs are ductal carcinoma in situ (DCIS), and the majority of DCIS cases present in the form of mammographic microcalcification. This study was performed in order to determine the value of features in predicting invasive disease in patients with mammographic calcification and to help determine which patients (with, Core Needle Biopsy-diagnosed DCIS) are the most appropriate candidates for Sentinel Lymph Node (SLN) biopsy. The original aspect of this study was to select patients with mammographic microcalcification but without an associated mass. The factor that we identified to be associated with invasive disease at final surgical excision was the presence of necrosis at core histology. SLN biopsy or complete axillary lymph node dissection was performed in 22 (40%) patients of whom only one (4.5%) had a micrometastasis. Further larger studies are needed to see if it would be interesting to propose a SLN biopsy in case of necrosis on CNB-diagnosed DCIS with microcalcifications but not associated with a mass. Copyright © 2012 Elsevier GmbH. All rights reserved.
Shin, Toshitaka; Smyth, Thomas B; Ukimura, Osamu; Ahmadi, Nariman; de Castro Abreu, Andre Luis; Oishi, Masakatsu; Mimata, Hiromitsu; Gill, Inderbir S
2017-08-01
To assess the diagnostic yield of targeted prostate biopsy in African-American (A-A) men using image fusion of multi-parametric magnetic resonance imaging (mpMRI) with real-time transrectal ultrasonography (US). We retrospectively analysed 661 patients (117 A-A and 544 Caucasian) who had mpMRI before biopsy and then underwent MRI/US image-fusion targeted biopsy (FTB) between October 2012 and August 2015. The mpMRIs were reported on a 5-point Likert scale of suspicion. Clinically significant prostate cancer (CSPC) was defined as biopsy Gleason score ≥7. After controlling for age, prostate-specific antigen level and prostate volume, there were no significant differences between A-A and Caucasian men in the detection rate of overall cancer (35.0% vs 34.2%, P = 0.9) and CSPC (18.8% vs 21.7%, P = 0.3) with MRI/US FTB. There were no significant differences between the races in the location of dominant lesions on mpMRI, and in the proportion of 5-point Likert scoring. In A-A men, MRI/US FTB from the grade 4-5 lesions outperformed random biopsy in the detection rate of overall cancer (70.6% vs 37.2%, P = 0.003) and CSPC (52.9% vs 12.4%, P < 0.001). MRI/US FTB outperformed random biopsy in cancer core length (5.0 vs 2.4 mm, P = 0.001), in cancer rate per core (24.9% vs 6.8%, P < 0.001), and in efficiency for detecting one patient with CSPC (mean number of cores needed 13.3 vs 81.9, P < 0.001), respectively. Our key finding confirms a lack of racial difference in the detection rate of overall prostate cancers and CSPC with MRI/US FTB between A-A and Caucasian men. MRI/US FTB detected more CSPC using fewer cores compared with random biopsy. © 2017 The Authors BJU International © 2017 BJU International Published by John Wiley & Sons Ltd.
Islam, Anwarul
2018-06-01
The optimal clinical evaluation of the bone marrow requires an examination of air-dried and well-stained films of the aspirated tissue along with a histopathological evaluation of adequately processed and properly stained core biopsy specimens. A bone marrow evaluation can be essential in establishing a diagnosis, determining the efficacy of treatment in haematological disorders and to monitor haematological status of patients following bone marrow/stem cell transplantation. It is also an essential component of the staging process for newly diagnosed malignancies. Currently available bone marrow aspiration needles are quite satisfactory and if properly used provide good-quality specimens for morphological evaluation. However, if a bone marrow core biopsy is concerned, several needles are currently in use but not all of them provide good-quality biopsy specimens for histological evaluation or are user friendly. We have compared the recently introduced Moeller Medical single use bone marrow core biopsy needle with the Jamshidi needle with marrow acquisition cradle (CareFusion), J-needle (Cardinal Health) and OnControl device (Vidacare). It is concluded that the Moeller Medical needle system has definite advantages over others and is recommended for routine use. © Article author(s) (or their employer(s) unless otherwise stated in the text of the article) 2018. All rights reserved. No commercial use is permitted unless otherwise expressly granted.
Fanchon, Louise M; Dogan, Snjezana; Moreira, Andre L; Carlin, Sean A; Schmidtlein, C Ross; Yorke, Ellen; Apte, Aditya P; Burger, Irene A; Durack, Jeremy C; Erinjeri, Joseph P; Maybody, Majid; Schöder, Heiko; Siegelbaum, Robert H; Sofocleous, Constantinos T; Deasy, Joseph O; Solomon, Stephen B; Humm, John L; Kirov, Assen S
2015-04-01
Core biopsies obtained using PET/CT guidance contain bound radiotracer and therefore provide information about tracer uptake in situ. Our goal was to develop a method for quantitative autoradiography of biopsy specimens (QABS), to use this method to correlate (18)F-FDG tracer uptake in situ with histopathology findings, and to briefly discuss its potential application. Twenty-seven patients referred for a PET/CT-guided biopsy of (18)F-FDG-avid primary or metastatic lesions in different locations consented to participate in this institutional review board-approved study, which complied with the Health Insurance Portability and Accountability Act. Autoradiography of biopsy specimens obtained using 5 types of needles was performed immediately after extraction. The response of autoradiography imaging plates was calibrated using dummy specimens with known activity obtained using 2 core-biopsy needle sizes. The calibration curves were used to quantify the activity along biopsy specimens obtained with these 2 needles and to calculate the standardized uptake value, SUVARG. Autoradiography images were correlated with histopathologic findings and fused with PET/CT images demonstrating the position of the biopsy needle within the lesion. Logistic regression analysis was performed to search for an SUVARG threshold distinguishing benign from malignant tissue in liver biopsy specimens. Pearson correlation between SUVARG of the whole biopsy specimen and average SUVPET over the voxels intersected by the needle in the fused PET/CT image was calculated. Activity concentrations were obtained using autoradiography for 20 specimens extracted with 18- and 20-gauge needles. The probability of finding malignancy in a specimen is greater than 50% (95% confidence) if SUVARG is greater than 7.3. For core specimens with preserved shape and orientation and in the absence of motion, one can achieve autoradiography, CT, and PET image registration with spatial accuracy better than 2 mm. The correlation coefficient between the mean specimen SUVARG and SUVPET was 0.66. Performing QABS on core-biopsy specimens obtained using PET/CT guidance enables in situ correlation of (18)F-FDG tracer uptake and histopathology on a millimeter scale. QABS promises to provide useful information for guiding interventional radiology procedures and localized therapies and for in situ high-spatial-resolution validation of radiopharmaceutical uptake. © 2015 by the Society of Nuclear Medicine and Molecular Imaging, Inc.
Petranovic, Milena; Gilman, Matthew D; Muniappan, Ashok; Hasserjian, Robert P; Digumarthy, Subba R; Muse, Victorine V; Sharma, Amita; Shepard, Jo-Anne O; Wu, Carol C
2015-10-01
The purpose of this study was to evaluate the diagnostic yield and accuracy of CT-guided percutaneous biopsy of anterior mediastinal masses and assess prebiopsy characteristics that may help to select patients with the highest diagnostic yield. Retrospective review of all CT-guided percutaneous biopsies of the anterior mediastinum conducted at our institution from January 2003 through December 2012 was performed to collect data regarding patient demographics, imaging characteristics of biopsied masses, presence of complications, and subsequent surgical intervention or medical treatment (or both). Cytology, core biopsy pathology, and surgical pathology results were recorded. A per-patient analysis was performed using two-tailed t test, Fisher's exact test, and Pearson chi-square test. The study cohort included 52 patients (32 men, 20 women; mean age, 49 years) with mean diameter of mediastinal mass of 6.9 cm. Diagnostic yield of CT-guided percutaneous biopsy was 77% (40/52), highest for thymic neoplasms (100% [11/11]). Non-diagnostic results were seen in 12 of 52 patients (23%), primarily in patients with lymphoma (75% [9/12]). Fine-needle aspiration yielded the correct diagnosis in 31 of 52 patients (60%), and core biopsy had a diagnostic rate of 77% (36/47). None of the core biopsies were discordant with surgical pathology. There was no statistically significant difference between the diagnostic and the nondiagnostic groups in patient age, lesion size, and presence of necrosis. The complication rate was 3.8% (2/52), all small self-resolving pneumothoraces. CT-guided percutaneous biopsy is a safe diagnostic procedure with high diagnostic yield (77%) for anterior mediastinal lesions, highest for thymic neoplasms (100%), and can potentially obviate more invasive procedures.
Diederich, S; Padge, B; Vossas, U; Hake, R; Eidt, S
2006-01-01
Purpose: To assess feasibility, results and complications in image-guided biopsies using a single needle design in various organs. Materials and methods: 100 consecutive percutaneous biopsies were performed in 54 females and 46 males aged 24–87 years (mean age/standard deviation: 64.5 +/− 12 years) using a full-core end-cut tri-axial full-automatic biopsy needle (18 gauge BioPince ™, InterV-MDTech, Gainesville, Florida) under CT (n=45) or ultrasound (n=55) guidance. In 63 biopsies a coaxial technique was used. Results: Biopsies were obtained of liver (n=32), lymph nodes (n=17), thyroid (n=11), lung (n=9), adrenal (n=9), pelvis (n=6), chest wall/pleura (n=6), mediastinum (n=4), lytic bone lesions (n=2), retroperitoneum (n=1), muscle (n=1), pancreas (n=1), peritoneum (n=1). Between 1 and 6 (mean/SD 2.83 +/− 0.92) needle passes were performed. In 77 cases a malignant (40 metastases, 37 primary tumours) and in 23 a benign lesion was diagnosed. Of the 23 benign lesions a specific diagnosis was possible in 22. In one case necrosis and haemorrhage was diagnosed. In this patient surgery and autopsy both revealed a mediastinal haematoma of unknown origin. Eight minor complications (mild pain/local haematoma requiring no therapy) and three major complications (three pneumothoraces in nine lung biopsies requiring two aspirations and one drainage) were observed. There was no mortality. Conclusion: Percutaneous image-guided biopsy using the described full-core end-cut needle resulted in a specific diagnosis in 99/100 consecutive biopsies in various organs with a low complication rate. We use this needle type for all CT- or US-guided biopsies in all organs except for solid bone. PMID:16766268
Donaldson, Alana R; Sieck, Leah; Booth, Christine N; Calhoun, Benjamin C
2016-12-01
The risk of finding carcinoma in excisions following a core needle biopsy diagnosis of radial scar is not well defined and clinical management is variable. The aim of this study is to determine the frequency of high-risk lesions, ductal carcinoma in situ, and invasive carcinoma in excisions following a core biopsy diagnosis of radial scar. Dedicated breast pathologists and radiologists correlated the histologic and radiologic findings and categorized radial scars as the target lesion or an incidental finding. High-risk lesions were defined as atypical hyperplasia or classical lobular carcinoma in situ. Of the 79 radial scars identified over a 14-year period, 22 were associated with atypia or carcinoma in the core biopsy. Thirty-seven (37) of the 57 benign radial scars underwent excision with benign findings in 30 (81%), high-risk lesions in six (16%), and flat epithelial atypia in one (3%). There were no upgrades to carcinoma. One patient with a benign radial scar developed a 3-mm focus of intermediate-grade estrogen receptor-positive ductal carcinoma in situ in the same quadrant of the ipsilateral breast 72 months after excision. One patient with an incidental un-excised benign radial scar was diagnosed with ductal carcinoma in situ at a separate site of suspicious calcifications. In this series, none of the benign radial scars was upgraded to carcinoma. Radial scar was the targeted lesion in all cases with high-risk lesions on excision. Surgical excision may not be mandatory for patients with benign incidental radial scars on core biopsy. Copyright © 2016 Elsevier Ltd. All rights reserved.
[The evolution of vacuum extraction in obstetrics].
Nikolov, A
2010-01-01
Vacuum extraction is one of the methods for assisted vaginal delivery. In this article the evolution of vacuum extraction in obstetrics is been discussed. Historical facts and data from the invention up to state-of-the-art vacuum systems in modern obstetrics are presented.
Soo, Mary Scott; Jarosz, Jennifer A; Wren, Anava A; Soo, Adrianne E; Mowery, Yvonne M; Johnson, Karen S; Yoon, Sora C; Kim, Connie; Hwang, E Shelley; Keefe, Francis J; Shelby, Rebecca A
2016-05-01
To evaluate the impact of guided meditation and music interventions on patient anxiety, pain, and fatigue during imaging-guided breast biopsy. After giving informed consent, 121 women needing percutaneous imaging-guided breast biopsy were randomized into three groups: (1) guided meditation; (2) music; (3) standard-care control group. During biopsy, the meditation and music groups listened to an audio-recorded, guided, loving-kindness meditation and relaxing music, respectively; the standard-care control group received supportive dialogue from the biopsy team. Immediately before and after biopsy, participants completed questionnaires measuring anxiety (State-Trait Anxiety Inventory Scale), biopsy pain (Brief Pain Inventory), and fatigue (modified Functional Assessment of Chronic Illness Therapy-Fatigue). After biopsy, participants completed questionnaires assessing radiologist-patient communication (modified Questionnaire on the Quality of Physician-Patient Interaction), demographics, and medical history. The meditation and music groups reported significantly greater anxiety reduction (P values < .05) and reduced fatigue after biopsy than the standard-care control group; the standard-care control group reported increased fatigue after biopsy. The meditation group additionally showed significantly lower pain during biopsy, compared with the music group (P = .03). No significant difference in patient-perceived quality of radiologist-patient communication was noted among groups. Listening to guided meditation significantly lowered biopsy pain during imaging-guided breast biopsy; meditation and music reduced patient anxiety and fatigue without compromising radiologist-patient communication. These simple, inexpensive interventions could improve women's experiences during core-needle breast biopsy. Copyright © 2016 American College of Radiology. Published by Elsevier Inc. All rights reserved.
Approaches to Design and Evaluation of Sandwich Composites
NASA Technical Reports Server (NTRS)
Shivakumar, Kunigal; Raju, I. S. (Technical Monitor); Ambur, D. (Technical Monitor)
2001-01-01
This report describes research during the period June 15, 1997 to October 31, 2000. This grant yielded a low cast manufacturing of composite sandwich structures technology and characterization interfacial and subinterfacial cracks in foam core sandwich panels. The manufacturing technology is called the vacuum assisted resin transfer (VARTM). The VARTM is suitable for processing composite materials both at ambient and elevated temperatures and of unlimited component size. This technology has been successfully transferred to a small business fiber preform manufacturing company 3TEX located in Cary, North Carolina. The grant also supported one Ph.D, one M.S and a number of under graduate students, and nine publications and Presentations.
Koegelenberg, Coenraad Frederik N; Bolliger, Christoph Thomas; Theron, Johan; Walzl, Gerhard; Wright, Colleen Anne; Louw, Mercia; Diacon, Andreas Henri
2010-10-01
Tuberculous pleuritis remains the commonest cause of exudative effusions in areas with a high prevalence of tuberculosis and histological and/or microbiological confirmation on pleural tissue is the gold standard for its diagnosis. Uncertainty remains regarding the choice of closed pleural biopsy needles. This prospective study compared ultrasound-assisted Abrams and Tru-Cut needle biopsies with regard to their diagnostic yield for pleural tuberculosis. 89 patients (54 men) of mean ± SD age 38.7 ± 16.7 years with pleural effusions and a clinical suspicion of tuberculosis were enrolled in the study. Transthoracic ultrasound was performed on all patients, who were then randomly assigned to undergo ≥ 4 Abrams needle biopsies followed by ≥ 4 Tru-Cut needle biopsies or vice versa. Medical thoracoscopy was performed on cases with non-diagnostic closed biopsies. Histological and/or microbiological proof of tuberculosis on any pleural specimen was considered the gold standard for pleural tuberculosis. Pleural tuberculosis was diagnosed in 66 patients, alternative diagnoses were established in 20 patients and 3 remained undiagnosed. Pleural biopsy specimens obtained with Abrams needles contained pleural tissue in 81 patients (91.0%) and were diagnostic for tuberculosis in 54 patients (sensitivity 81.8%), whereas Tru-Cut needle biopsy specimens only contained pleural tissue in 70 patients (78.7%, p=0.015) and were diagnostic in 43 patients (sensitivity 65.2%, p=0.022). Ultrasound-assisted pleural biopsies performed with an Abrams needle are more likely to contain pleura and have a significantly higher diagnostic sensitivity for pleural tuberculosis.
Electrical property sensing biopsy needle for prostate cancer detection.
Mishra, V; Schned, A R; Hartov, A; Heaney, J A; Seigne, J; Halter, R J
2013-11-01
Significant electrical property differences have been demonstrated to exist between malignant and benign prostate tissues. We evaluated how well a custom designed clinically deployable electrical property sensing biopsy needle is able to discriminate between these tissue types in an ex vivo prostate model. An electrical impedance spectroscopy (EIS) sensing biopsy (Bx) needle was developed to record resistive (ρR) and reactive (ρX) components of electrical impedance from 100 Hz to 1 MHz. Standard twelve-core biopsy protocols were followed, in which the EIS-Bx device was used to gauge electrical properties prior to extracting tissue cores through biopsy needle firing from 36 ex vivo human prostates. Histopathological assessment of the cores was statistically compared to the impedance spectrum gauged from each core. The magnitudes of the mean resistive and reactive components were significantly higher in cancer tissues (P < 0.05). ROC curves showed that ρR at 63.09 kHz was optimal for discriminating cancer from benign tissues; this parameter had 75.4% specificity, 76.1% sensitivity, and ROC AUC of 0.779. Similarly, 251.1 kHz was optimal when using ρX to discriminate cancer from benign tissues; this parameter had a 77.9% specificity, 71.4% sensitivity, and ROC AUC of 0.79. Significant electrical property differences noted between benign and malignant prostate tissues suggest the potential efficacy an EIS-Bx device would provide for cancer detection in a clinical setting. By sensing a greater fraction of the prostate's volume in real-time, the EIS-Bx device has the potential to improve the accuracy of cancer grading and volume estimation made with current biopsy procedures. © 2013 Wiley Periodicals, Inc.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Fukuda, Hozumi, E-mail: fkdhzmrad@mitsuihosp.or.jp; Ibukuro, Kenji; Tsukiyama, Toshitaka
We evaluated the value of CT-guided transthoracic core biopsy for the diagnosis of mycobacterial pulmonary nodules. The 30 subjects in this study had pulmonary nodules that had been either diagnosed histopathologically as tuberculosis or were suspected as tuberculosis based on a specimen obtained by CT-guided transthoracic core biopsy. The histopathological findings, the existence of acid-fast bacilli in the biopsy specimens, and the clinical course of the patients after the biopsy were reviewed retrospectively. Two of the three histological findings for tuberculosis that included epithelioid cells, multinucleated giant cells and caseous necrosis were observed in 21 of the nodules which weremore » therefore diagnosed as histological tuberculosis. Six of these 21 nodules were positive for acid-fast bacilli, confirming the diagnosis of tuberculosis. Thirteen of the 21 nodules did not contain acid-fast bacilli but decreased in size in response to antituberculous treatment and were therefore diagnosed as clinical tuberculosis. Seven nodules with only caseous necrosis were diagnosed as suspected tuberculosis, with a final diagnosis of tuberculosis being made in 4 of the nodules and a diagnosis of old tuberculosis in 2 nodules. Two nodules with only multinucleated giant cells were diagnosed as suspected tuberculosis with 1 of these nodules being diagnosed finally as tuberculosis and the other nodule as a nonspecific granuloma. When any two of the three following histopathological findings - epithelioid cells, multinucleated giant cells or caseous necrosis - are observed in a specimen obtained by CT-guided transthoracic core biopsy, the diagnosis of tuberculosis can be established without the detection of acid-fast bacilli or Mycobacterium tuberculosis.« less
Mina, Lida; Soule, Sharon E; Badve, Sunil; Baehner, Fredrick L; Baker, Joffre; Cronin, Maureen; Watson, Drew; Liu, Mei-Lan; Sledge, George W; Shak, Steve; Miller, Kathy D
2007-06-01
Primary chemotherapy provides an ideal opportunity to correlate gene expression with response to treatment. We used paraffin-embedded core biopsies from a completed phase II trial to identify genes that correlate with response to primary chemotherapy. Patients with newly diagnosed stage II or III breast cancer were treated with sequential doxorubicin 75 mg/M2 q2 wks x 3 and docetaxel 40 mg/M2 weekly x 6; treatment order was randomly assigned. Pretreatment core biopsy samples were interrogated for genes that might correlate with pathologic complete response (pCR). In addition to the individual genes, the correlation of the Oncotype DX Recurrence Score with pCR was examined. Of 70 patients enrolled in the parent trial, core biopsies samples with sufficient RNA for gene analyses were available from 45 patients; 9 (20%) had inflammatory breast cancer (IBC). Six (14%) patients achieved a pCR. Twenty-two of the 274 candidate genes assessed correlated with pCR (p < 0.05). Genes correlating with pCR could be grouped into three large clusters: angiogenesis-related genes, proliferation related genes, and invasion-related genes. Expression of estrogen receptor (ER)-related genes and Recurrence Score did not correlate with pCR. In an exploratory analysis we compared gene expression in IBC to non-inflammatory breast cancer; twenty-four (9%) of the genes were differentially expressed (p < 0.05), 5 were upregulated and 19 were downregulated in IBC. Gene expression analysis on core biopsy samples is feasible and identifies candidate genes that correlate with pCR to primary chemotherapy. Gene expression in IBC differs significantly from noninflammatory breast cancer.
MRI-Targeted or Standard Biopsy for Prostate-Cancer Diagnosis.
Kasivisvanathan, Veeru; Rannikko, Antti S; Borghi, Marcelo; Panebianco, Valeria; Mynderse, Lance A; Vaarala, Markku H; Briganti, Alberto; Budäus, Lars; Hellawell, Giles; Hindley, Richard G; Roobol, Monique J; Eggener, Scott; Ghei, Maneesh; Villers, Arnauld; Bladou, Franck; Villeirs, Geert M; Virdi, Jaspal; Boxler, Silvan; Robert, Grégoire; Singh, Paras B; Venderink, Wulphert; Hadaschik, Boris A; Ruffion, Alain; Hu, Jim C; Margolis, Daniel; Crouzet, Sébastien; Klotz, Laurence; Taneja, Samir S; Pinto, Peter; Gill, Inderbir; Allen, Clare; Giganti, Francesco; Freeman, Alex; Morris, Stephen; Punwani, Shonit; Williams, Norman R; Brew-Graves, Chris; Deeks, Jonathan; Takwoingi, Yemisi; Emberton, Mark; Moore, Caroline M
2018-05-10
Multiparametric magnetic resonance imaging (MRI), with or without targeted biopsy, is an alternative to standard transrectal ultrasonography-guided biopsy for prostate-cancer detection in men with a raised prostate-specific antigen level who have not undergone biopsy. However, comparative evidence is limited. In a multicenter, randomized, noninferiority trial, we assigned men with a clinical suspicion of prostate cancer who had not undergone biopsy previously to undergo MRI, with or without targeted biopsy, or standard transrectal ultrasonography-guided biopsy. Men in the MRI-targeted biopsy group underwent a targeted biopsy (without standard biopsy cores) if the MRI was suggestive of prostate cancer; men whose MRI results were not suggestive of prostate cancer were not offered biopsy. Standard biopsy was a 10-to-12-core, transrectal ultrasonography-guided biopsy. The primary outcome was the proportion of men who received a diagnosis of clinically significant cancer. Secondary outcomes included the proportion of men who received a diagnosis of clinically insignificant cancer. A total of 500 men underwent randomization. In the MRI-targeted biopsy group, 71 of 252 men (28%) had MRI results that were not suggestive of prostate cancer, so they did not undergo biopsy. Clinically significant cancer was detected in 95 men (38%) in the MRI-targeted biopsy group, as compared with 64 of 248 (26%) in the standard-biopsy group (adjusted difference, 12 percentage points; 95% confidence interval [CI], 4 to 20; P=0.005). MRI, with or without targeted biopsy, was noninferior to standard biopsy, and the 95% confidence interval indicated the superiority of this strategy over standard biopsy. Fewer men in the MRI-targeted biopsy group than in the standard-biopsy group received a diagnosis of clinically insignificant cancer (adjusted difference, -13 percentage points; 95% CI, -19 to -7; P<0.001). The use of risk assessment with MRI before biopsy and MRI-targeted biopsy was superior to standard transrectal ultrasonography-guided biopsy in men at clinical risk for prostate cancer who had not undergone biopsy previously. (Funded by the National Institute for Health Research and the European Association of Urology Research Foundation; PRECISION ClinicalTrials.gov number, NCT02380027 .).
Huang, Haifeng; Wang, Wei; Lin, Tingsheng; Zhang, Qing; Zhao, Xiaozhi; Lian, Huibo; Guo, Hongqian
2016-11-17
To compare the complications of traditional transrectal (TR) prostate biopsy and image fusion guided transperineal (TP) prostate biopsy in our center. Two hundred and fourty-two patients who underwent prostate biopsy from August 2014 to January 2015were reviewed. Among them, 144 patients underwent systematic 12-core transrectal ultrasonography (TRUS) guided prostate biopsy (TR approach) while 98 patients underwent free-hand transperineal targeted biopsy with TRUS and multi-parameter magnetic resonance imaging (mpMRI) fusion images (TP approach). The complications of the two groups were presented and a simple statistical analysis was performed to compare the two groups. The cohort of our study include242 patients, including 144 patients underwent TR biopsies while 98 patients underwentTP biopsies. There was no significant difference of major complications, including sepsis, bleeding and other complication requiring admissionbetween the two groups (P > 0.05). The incidence rate of infection and rectal bleeding in TR was much higher than TP (p < 0.05), but the incidence rate of perineal swelling in TP was much higher than TR (p < 0.05). There were no significant differences of minor complications including hematuria, lower urinary tract symptoms (LUTS), dysuria, and acuteurinary retention between the two groups (p > 0.05). The present study supports the safety of both techniques. Free-handTP targeted prostate biopsy with real-time fusion imaging of mpMRI and TR ultrasound is a good approach for prostate biopsy.
Psooy, B J; Clark, T W; Beecroft, J R; Malatjalian, D
2001-01-01
Obtaining transjugular liver biopsy specimens with use of single-use needle systems is expensive, whereas biopsy specimens obtained with use of reusable needle systems are frequently associated with inadequate core specimens. The authors report their experience with the reusable Cook Shark Jaw biopsy needle, including diagnostic yield, complications, and cost-effectiveness. A retrospective audit was performed of a cohort of 134 patients who underwent 136 transjugular liver biopsies with use of a reusable 16-gauge Shark Jaw needle during a 30-month period. Specimen adequacy and complication rates were assessed and direct costs of expendable components calculated. Cost-effectiveness was expressed as cost-per-successful biopsy. Biopsies were technically successful in 126 of 136 (93%) patients, with diagnostic histologic core specimens obtained in 124 of 126 (98%) patients, for an overall success rate of 91%. Complications included capsular penetration in six (4.4%) patients, cardiac arrhythmia in two (1.5%) patients, and puncture site hematoma or bleeding in 10 (7.4%) patients. Three tract embolizations were performed for capsular penetration. No instances of subcapsular hematoma, hemoperitoneum, or sepsis occurred, and no deaths were attributed to the procedure. The cost of expendable components totaled $103 per biopsy, corresponding to a cost-effectiveness of $113/successful biopsy. Transjugular liver biopsy specimens obtained with use of the Shark Jaw needle have a diagnostic yield comparable to those obtained with use of single-use biopsy systems, at a substantially lower cost with no increase in serious complications.
Ejector subassembly for dual wall air drilling
DOE Office of Scientific and Technical Information (OSTI.GOV)
Kolle, J.J.
1996-09-01
The dry drilling system developed for the Yucca Mountain Site Characterization Project incorporates a surface vacuum system to prevent drilling air and cuttings from contaminating the borehole wall during coring operations. As the drilling depth increases, however there is a potential for borehole contamination because of the limited volume of air which can be removed by the vacuum system. A feasibility analysis has shown that an ejector subassembly mounted in the drill string above the core barrel could significantly enhance the depth capacity of the dry drilling system. The ejector subassembly would use a portion of the air supplied tomore » the core bit to maintain a vacuum on the hole bottom. The results of a design study including performance testing of laboratory scale ejector simulator are presented here.« less
Spratt, Daniel E; Zumsteg, Zach; Ghadjar, Pirus; Pangasa, Misha; Pei, Xin; Fine, Samson W; Yamada, Yoshiya; Kollmeier, Marisa; Zelefsky, Michael J
2013-04-01
To analyze the effect of primary Gleason (pG) grade among a large cohort of Gleason 7 prostate cancer patients treated with external beam radiation therapy (EBRT). From May 1989 to January 2011, 1190 Gleason 7 patients with localized prostate cancer were treated with EBRT at a single institution. Of these patients, 613 had a Gleason 7 with a minimum of a sextant biopsy with nonfragmented cores and full biopsy core details available, including number of cores of cancer involved, percentage individual core involvement, location of disease, bilaterality, and presence of perineural invasion. Median follow-up was 6 years (range, 1-16 years). The prognostic implication for the following outcomes was analyzed: biochemical recurrence-free survival (bRFS), distant metastasis-free survival (DMFS), and prostate cancer-specific mortality (PCSM). The 8-year bRFS rate for pG3 versus pG4 was 77.6% versus 61.3% (P<.0001), DMFS was 96.8% versus 84.3% (P<.0001), and PCSM was 3.7% versus 8.1% (P=.002). On multivariate analysis, pG4 predicted for significantly worse outcome in all parameters. Location of disease (apex, base, mid-gland), perineural involvement, maximum individual core involvement, and the number of Gleason 3+3, 3+4, or 4+3 cores did not predict for distant metastases. Primary Gleason grade 4 independently predicts for worse bRFS, DMFS, and PCSM among Gleason 7 patients. Using complete core information can allow clinicians to utilize pG grade as a prognostic factor, despite not having the full pathologic details from a prostatectomy specimen. Future staging and risk grouping should investigate the incorporation of primary Gleason grade when complete biopsy core information is used. Copyright © 2013 Elsevier Inc. All rights reserved.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Spratt, Daniel E.; Zumsteg, Zach; Ghadjar, Pirus
2013-04-01
Purpose: To analyze the effect of primary Gleason (pG) grade among a large cohort of Gleason 7 prostate cancer patients treated with external beam radiation therapy (EBRT). Methods and Materials: From May 1989 to January 2011, 1190 Gleason 7 patients with localized prostate cancer were treated with EBRT at a single institution. Of these patients, 613 had a Gleason 7 with a minimum of a sextant biopsy with nonfragmented cores and full biopsy core details available, including number of cores of cancer involved, percentage individual core involvement, location of disease, bilaterality, and presence of perineural invasion. Median follow-up was 6more » years (range, 1-16 years). The prognostic implication for the following outcomes was analyzed: biochemical recurrence-free survival (bRFS), distant metastasis-free survival (DMFS), and prostate cancer-specific mortality (PCSM). Results: The 8-year bRFS rate for pG3 versus pG4 was 77.6% versus 61.3% (P<.0001), DMFS was 96.8% versus 84.3% (P<.0001), and PCSM was 3.7% versus 8.1% (P=.002). On multivariate analysis, pG4 predicted for significantly worse outcome in all parameters. Location of disease (apex, base, mid-gland), perineural involvement, maximum individual core involvement, and the number of Gleason 3+3, 3+4, or 4+3 cores did not predict for distant metastases. Conclusions: Primary Gleason grade 4 independently predicts for worse bRFS, DMFS, and PCSM among Gleason 7 patients. Using complete core information can allow clinicians to utilize pG grade as a prognostic factor, despite not having the full pathologic details from a prostatectomy specimen. Future staging and risk grouping should investigate the incorporation of primary Gleason grade when complete biopsy core information is used.« less
Execution of robot-assisted biopsies within the clinical context.
Rovetta, A; Sala, R
1995-01-01
This paper describes the first prostatic biopsy on a human patient using a robotic and telerobotic system. This system was designed at the Politecnico di Milano, and the biopsy was performed on April 7, 1995, in the Hospital Policlinico in Milan, Italy.
Vacuum-assisted closure therapy in the management of lung abscess.
Sziklavari, Zsolt; Ried, Michael; Hofmann, Hans-Stefan
2014-09-06
Despite significant advances in the treatment of thoracic infections, complex lung abscess remains a problem in modern thoracic surgery. We describe the novel application of vacuum-assisted closure for the treatment of a lung abscess. The technical details and preliminary results are reported. After the initial failed conservative treatment of an abscess, minimally invasive surgical intervention was performed with vacuum-assisted closure. The vacuum sponges were inserted in the abscess cavity at the most proximal point to the pleural surface. The intercostal space of the chest wall above the entering place was secured by a soft tissue retractor. The level of suction was initially set to 100 mm Hg, with a maximum suction of 125 mm Hg. The sponge was changed once on the 3rd postoperative day. The abscess cavity was rapidly cleaned and decreased in size. The mini-thoracotomy could be closed on the 9th postoperative day. Closure of the cavity was simple, without any short- or long-term treatment failure. This technique reduced the trauma associated with the procedure. The patient was discharged on the 11th postoperative day. Vacuum-assisted closure systems should be considered for widespread use as an alternative option for the treatment of complicated pulmonary abscess in elderly, debilitated, immunocompromised patients after failed conservative treatment.
High-frequency ultrasound imaging for breast cancer biopsy guidance
Cummins, Thomas; Yoon, Changhan; Choi, Hojong; Eliahoo, Payam; Kim, Hyung Ham; Yamashita, Mary W.; Hovanessian-Larsen, Linda J.; Lang, Julie E.; Sener, Stephen F.; Vallone, John; Martin, Sue E.; Kirk Shung, K.
2015-01-01
Abstract. Image-guided core needle biopsy is the current gold standard for breast cancer diagnosis. Microcalcifications, an important radiographic finding on mammography suggestive of early breast cancer such as ductal carcinoma in situ, are usually biopsied under stereotactic guidance. This procedure, however, is uncomfortable for patients and requires the use of ionizing radiation. It would be preferable to biopsy microcalcifications under ultrasound guidance since it is a faster procedure, more comfortable for the patient, and requires no radiation. However, microcalcifications cannot reliably be detected with the current standard ultrasound imaging systems. This study is motivated by the clinical need for real-time high-resolution ultrasound imaging of microcalcifications, so that biopsies can be accurately performed under ultrasound guidance. We have investigated how high-frequency ultrasound imaging can enable visualization of microstructures in ex vivo breast tissue biopsy samples. We generated B-mode images of breast tissue and applied the Nakagami filtering technique to help refine image output so that microcalcifications could be better assessed during ultrasound-guided core biopsies. We describe the preliminary clinical results of high-frequency ultrasound imaging of ex vivo breast biopsy tissue with microcalcifications and without Nakagami filtering and the correlation of these images with the pathology examination by hematoxylin and eosin stain and whole slide digital scanning. PMID:26693167
Berney, Daniel M; Algaba, Ferran; Camparo, Philippe; Compérat, Eva; Griffiths, David; Kristiansen, Glen; Lopez-Beltran, Antonio; Montironi, Rodolfo; Varma, Murali; Egevad, Lars
2014-02-01
The Gleason scoring system underwent revision at the International Society of Urological Pathology (ISUP) conference in 2005. It is not known how uropathologists have interpreted its recommendations. A web-based survey to European Network of Uropathology members received replies from 266 pathologists in 22 countries. Eighty-nine per cent claimed to follow ISUP recommendations. Key areas of disagreement included the following. Smoothly rounded cribriform glands were assigned Gleason pattern (GP) 3 by 51% and GP 4 by 49%. Necrosis was diagnosed as GP 5 by 62%. Any amount of secondary pattern of higher grade in needle biopsies was included in the Gleason score by 58%. Tertiary GP of higher grade on needle biopsies was included in the Gleason score by only 58%. If biopsy cores were embedded separately, only 56% would give a Gleason score for each core/slide examined; 68% would give a concluding Gleason score and the most common method was a global Gleason score (77%). Among those who blocked multiple biopsy cores together, 46% would only give an overall Gleason score for the case. Misinterpretation of ISUP 2005 is widespread, and may explain the variation in Gleason scoring seen. Clarity and uniformity in teaching ISUP 2005 recommendations is necessary. © 2013 John Wiley & Sons Ltd.
Politi, Y; Levi, A; Enk, C D; Lapidoth, M
2015-12-01
Acne treatment by a mid-infrared laser may be unsatisfactory due to deeply situated acne-affected sebaceous glands which serve as its target. Skin manipulation by vacuum and contact cooling may improve laser-skin interaction, reduce pain sensation, and increase overall safety and efficacy. To evaluate the safety and efficacy of acne treatment using an integrated cooling-vacuum-assisted 1540-nm erbium:glass laser, a prospective interventional study was conducted. It included 12 patients (seven men and five women) suffering from mild-to-moderate acne vulgaris. The device utilizes a mid-infrared 1540-nm laser (Alma Lasers Ltd. Caesarea, Israel), which is integrated with combined cooling-vacuum-assisted technology. An acne lesion is initially manipulated upon contact by a vacuum-cooling-assisted tip, followed by three to four stacked laser pulses (500-600 mJ, 4 mm spot size, and frequency of 2 Hz). Patients underwent four to six treatment sessions with a 2-week interval and were followed-up 1 and 3 months after the last treatment. Clinical photographs were taken by high-resolution digital camera before and after treatment. Clinical evaluation was performed by two independent dermatologists, and results were graded on a scale of 0 (exacerbation) to 4 (76-100 % improvement). Patients' and physicians' satisfaction was also recorded. Pain perception and adverse effects were evaluated as well. All patients demonstrated a moderate to significant improvement (average score of 3.6 and 2.0 within 1 and 3 months, respectively, following last treatment session). No side effects, besides a transient erythema, were observed. Cooling-vacuum-assisted 1540-nm laser is safe and effective for the treatment of acne vulgaris.
Kravchick, Sergey; Cytron, Shmuel; Stepnov, Eugeny; Ben-Dor, David; Kravchenko, Yakov; Peled, Ronit
2009-06-01
In this study, we tried to design a scheme for performing transrectal ultrasonographic (TRUS)-biopsies that would be accurate and include the optimal number of cores. We included in this study 600 consecutive patients with suspicious findings on a per-rectum examination and/or an elevated prostate-specific antigen (PSA) (>4 ng/mL) level. Patients were followed for 7 to 10 years. In all patients, we took from 8 to 16 biopsy samples, according to the prostate volume, from the lateral aspects. In the second session, the biopsy samples were taken medially; in the third session, we included the transitional zone, while in consecutive sessions, we increased the number of cores from all areas. Only 573 of the patients remained in follow-up. TRUS-biopsy detected prostate cancer (PCa) in 257 patients (44.85% overall detection rate). The detection rate in the first and second sessions was 32.98% and 14.94%, respectively, reaching 13.2% and 2.17%, in the third and fourth sessions, respectively. Prostate volumes were significantly smaller (52.9 +/- 22.4 cc vs 58.9 +/- 23.8 cc, P < 0.002) and the PSA/adenoma/prostate volumes ratio (ad-pro) ratio was higher (18.3 +/- 9 vs 13.96, P < 0/001) in the patients with PCa. Patients with PCa underwent fewer biopsy procedures and biopsy sessions than patients without a diagnosis of PCa (14.9 +/- 8.9 vs 20.4 +/- 12, P < 0.001;1.3 +/- 0.6 vs 1.7 +/- 0.9, P < 0.001). Biopsy samples obtained from the base were positive for cancer only in larger prostates with a mean volume of 54.3 +/- 15.3 cc. Numbers of biopsy procedures and PSA/ad-pro ratio were the strongest predictive factors for PCa detection (P < 0.001). In patients with a prostate volume >or=53 cc and PSA/ad-pro ratio >or=18, the optimal biopsy cores should be >or=15. Using this scheme, the discontinuation of biopsy procedures might be considered after three consecutive sessions.
Epstein, Jonathan I.; Feng, Zhaoyong; Trock, Bruce J.; Pierorazio, Phillip M.
2015-01-01
Background Prior studies assessing the correlation of Gleason score (GS) at needle biopsy and corresponding radical prostatectomy (RP) predated the use of the modified Gleason scoring system and did not factor in tertiary grade patterns. Objective To assess the relation of biopsy and RP grade in the largest study to date. Design, setting, and participants A total of 7643 totally embedded RP and corresponding needle biopsies (2004–2010) were analyzed according to the updated Gleason system. Interventions All patients underwent prostate biopsy prior to RP. Measurements The relation of upgrading or downgrading to patient and cancer characteristics was compared using the chi-square test, Student t test, and multivariable logistic regression. Results and limitations A total of 36.3% of cases were upgraded from a needle biopsy GS 5–6 to a higher grade at RP (11.2% with GS 6 plus tertiary). Half of the cases had matching GS 3 + 4 = 7 at biopsy and RP with an approximately equal number of cases downgraded and upgraded at RP. With biopsy GS 4 + 3 = 7, RP GS was almost equally 3 + 4 = 7 and 4 + 3 = 7. Biopsy GS 8 led to an almost equal distribution between RP GS 4 + 3 = 7, 8, and 9–10. A total of 58% of the cases had matching GS 9–10 at biopsy and RP. In multivariable analysis, increasing age (p < 0.0001), increasing serum prostate-specific antigen level (p < 0.0001), decreasing RP weight (p < 0.0001), and increasing maximum percentage cancer/core (p < 0.0001) predicted the upgrade from biopsy GS 5–6 to higher at RP. Despite factoring in multiple variables including the number of positive cores and the maximum percentage of cancer per core, the concordance indexes were not sufficiently high to justify the use of nomograms for predicting upgrading and downgrading for the individual patient. Conclusions Almost 20% of RP cases have tertiary patterns. A needle biopsy can sample a tertiary higher Gleason pattern in the RP, which is then not recorded in the standard GS reporting, resulting in an apparent overgrading on the needle biopsy. PMID:22336380
Epstein, Jonathan I; Feng, Zhaoyong; Trock, Bruce J; Pierorazio, Phillip M
2012-05-01
Prior studies assessing the correlation of Gleason score (GS) at needle biopsy and corresponding radical prostatectomy (RP) predated the use of the modified Gleason scoring system and did not factor in tertiary grade patterns. To assess the relation of biopsy and RP grade in the largest study to date. A total of 7643 totally embedded RP and corresponding needle biopsies (2004-2010) were analyzed according to the updated Gleason system. All patients underwent prostate biopsy prior to RP. The relation of upgrading or downgrading to patient and cancer characteristics was compared using the chi-square test, Student t test, and multivariable logistic regression. A total of 36.3% of cases were upgraded from a needle biopsy GS 5-6 to a higher grade at RP (11.2% with GS 6 plus tertiary). Half of the cases had matching GS 3+4=7 at biopsy and RP with an approximately equal number of cases downgraded and upgraded at RP. With biopsy GS 4+3=7, RP GS was almost equally 3+4=7 and 4+3=7. Biopsy GS 8 led to an almost equal distribution between RP GS 4+3=7, 8, and 9-10. A total of 58% of the cases had matching GS 9-10 at biopsy and RP. In multivariable analysis, increasing age (p<0.0001), increasing serum prostate-specific antigen level (p<0.0001), decreasing RP weight (p<0.0001), and increasing maximum percentage cancer/core (p<0.0001) predicted the upgrade from biopsy GS 5-6 to higher at RP. Despite factoring in multiple variables including the number of positive cores and the maximum percentage of cancer per core, the concordance indexes were not sufficiently high to justify the use of nomograms for predicting upgrading and downgrading for the individual patient. Almost 20% of RP cases have tertiary patterns. A needle biopsy can sample a tertiary higher Gleason pattern in the RP, which is then not recorded in the standard GS reporting, resulting in an apparent overgrading on the needle biopsy. Copyright © 2012 European Association of Urology. Published by Elsevier B.V. All rights reserved.
Olson, Michael C; Atwell, Thomas D; Mynderse, Lance A; King, Bernard F; Welch, Timothy; Goenka, Ajit H
2017-08-01
The purpose of our study was to examine the safety and diagnostic utility of transgluteal CT-guided prostate biopsy for prostate sampling in patients without rectal access. Seventy-three biopsies were performed in 65 patients over a 13-year period (2002-2015). Mean prostate-specific antigen (PSA) at biopsy was 7.8 ng/mL (range 0.37-31.5). Electronic medical records were reviewed for procedural details and complications. Mean PSA and number of cores in malignant and benign cohorts were compared with Student's t test. Technical success rate was 97.3% (71/73; mean cores 8, range 3-28). Of these, 43.6% (31/71) yielded malignancy (mean Gleason score 7, range 6-10) and 56.3% (40/71) yielded benign tissue. The only complication was an asymptomatic periprostatic hematoma (1/73; 1.4%). In 14 patients who underwent surgery, Gleason scores were concordant in 71.4% (10/14) and discordant in 28.6% (4/14; Gleason 6 on biopsy but Gleason 7 on surgical specimen). Mean effective radiation dose was 18.5 mSv (median 15.0, range 4.4-86.2). There was no significant difference in either mean PSA (p = 0.06) or number of core specimens (p = 0.33) between malignant and benign cohorts. CT-guided transgluteal prostate biopsy is highly safe and reliable for the detection of prostate cancer in men without rectal access. • Prostate cancer detection in men without rectal access is challenging. • CT-guided transgluteal prostate biopsy is safe and effective in these patients. • CT-guided biopsy may be particularly effective in diagnosing high-grade prostate cancer. • Unilateral CT-guided biopsy may be effective in patients with focal lesions. • The radiation exposure with this technique is acceptable.
Modified Core Wash Cytology: A reliable same day biopsy result for breast clinics.
Bulte, J P; Wauters, C A P; Duijm, L E M; de Wilt, J H W; Strobbe, L J A
2016-12-01
Fine Needle Aspiration Biopsy (FNAB), Core Needle biopsy (CNB) and hybrid techniques including Core Wash Cytology (CWC) are available for same-day diagnosis in breast lesions. In CWC a washing of the biopsy core is processed for a provisional cytological diagnosis, after which the core is processed like a regular CNB. This study focuses on the reliability of CWC in daily practice. All consecutive CWC procedures performed in a referral breast centre between May 2009 and May 2012 were reviewed, correlating CWC results with the CNB result, definitive diagnosis after surgical resection and/or follow-up. Symptomatic as well as screen-detected lesions, undergoing CNB were included. 1253 CWC procedures were performed. Definitive histology showed 849 (68%) malignant and 404 (32%) benign lesions. 80% of CWC procedures yielded a conclusive diagnosis: this percentage was higher amongst malignant lesions and lower for benign lesions: 89% and 62% respectively. Sensitivity and specificity of a conclusive CWC result were respectively 98.3% and 90.4%. The eventual incidence of malignancy in the cytological 'atypical' group (5%) was similar to the cytological 'benign' group (6%). CWC can be used to make a reliable provisional diagnosis of breast lesions within the hour. The high probability of conclusive results in malignant lesions makes CWC well suited for high risk populations. Copyright © 2016 Elsevier Ltd, BASO ~ the Association for Cancer Surgery, and the European Society of Surgical Oncology. All rights reserved.
Son, Intae; Lee, Byungsun; Kim, Jae Hong; Kim, Chunho; Yoo, Ji Yong; Ahn, Byung Wook; Hwang, Jeongho; Lee, Jonghyuk; Lee, Jun Hyup
2018-05-23
The spontaneous separation of a polymer thin film from a substrate is an innovative technology that will enable material recycling and reduce manufacturing cost in the film industry, and this can be applied in a wide range of applications, from optical films to wearable devices. Here, we present an unprecedented spontaneous strategy for separating transparent polymer films from substrates on the basis of microbubble generation using nanocapsules containing an evaporable material. The core-shell nanocapsules are prepared from poly(methyl methacrylate)-polyethyleneimine nanoparticles via the encapsulation of methylcyclohexane (MCH). A spherical nanostructure with a vaporizable core is obtained, with the heat-triggered gas release ability leading to the formation of microbubbles. Our separation method applied to transparent polymer films doped with a small amount of the nanocapsules encapsulating evaporable MCH enables spontaneous detachment of thin films from substrates via vacuum-assisted rapid vaporization of MCH over a short separation time, and clear detachment of the film is achieved with no deterioration of the inherent optical transparency and adhesive property compared to a pristine film.
O'Sullivan, Paul J; Gorman, Grainne M; Hardiman, Orla M; Farrell, Michael J; Logan, P Mark
2006-01-01
The purpose of this study was to evaluate the feasibility of sonographically guided percutaneous muscle biopsy in the investigation of neuromuscular disorders. Sonographically guided percutaneous needle biopsy of skeletal muscle was performed with a 14-gauge core biopsy system in 40 patients over a 24-month period. Patients were referred from the Department of Neurology under investigation for neuromuscular disorders. Sonography was used to find suitable tissue and to avoid major vascular structures. A local anesthetic was applied below skin only. A 3- to 4-mm incision was made. Three 14-gauge samples were obtained from each patient. All samples were placed on saline-dampened gauze and sent for neuropathologic analysis. As a control, we retrospectively assessed results of the 40 most recent muscle samples acquired via open surgical biopsy. With the use of sonography, 32 (80%) of 40 patients had a histologic diagnosis made via percutaneous needle biopsy. This included 26 (93%) of 28 patients with acute muscular disease and 6 (50%) of 12 patients with chronic disease. In the surgical group (all acute disease), 38 (95%) of 40 patients had diagnostic tissue attained. Sonographically guided percutaneous 14-gauge core skeletal muscle biopsy is a useful procedure, facilitating diagnosis in acute muscular disease. It provides results comparable with those of open surgical biopsy in acute muscular disease. It may also be used in chronic muscular disease but repeated or open biopsy may be needed.
Samitier, C Beatriz; Guirao, Lluis; Costea, Maria; Camós, Josep M; Pleguezuelos, Eulogio
2016-02-01
Lower limb amputation leads to impaired balance, ambulation, and transfers. Proper fit of the prosthesis is a determining factor for successful ambulation. Vacuum-assisted socket systems extract air from the socket, which decreases pistoning and probability of soft-tissue injuries and increases proprioception and socket comfort. To investigate the effect of vacuum-assisted socket system on transtibial amputees' performance-based and perceived balance, transfers, and gait. Quasi-experimental before-and-after study. Subjects were initially assessed using their prosthesis with the regular socket and re-evaluated 4 weeks after fitting including the vacuum-assisted socket system. We evaluated the mobility grade using Medicare Functional Classification Level, Berg Balance Scale, Four Square Step Test, Timed Up and Go Test, the 6-Min Walk Test, the Locomotor Capabilities Index, Satisfaction with Prosthesis (SAT-PRO questionnaire), and Houghton Scale. A total of 16 unilateral transtibial dysvascular amputees, mean age 65.12 (standard deviation = 10.15) years. Using the vacuum-assisted socket system, the patients significantly improved in balance, gait, and transfers: scores of the Berg Balance Scale increased from 45.75 (standard deviation = 6.91) to 49.06 (standard deviation = 5.62) (p < 0.01), Four Square Step Test decreased from 18.18 (standard deviation = 3.84) s to 14.97 (3.9) s (p < 0.01), Timed Up and Go Test decreased from 14.3 (standard deviation = 3.29) s to 11.56 (2.46) s (p < 0.01). The distance walked in the 6-Min Walk Test increased from 288.53 (standard deviation = 59.57) m to 321.38 (standard deviation = 72.81) m (p < 0.01). Vacuum-assisted socket systems are useful for improving balance, gait, and transfers in over-50-year-old dysvascular transtibial amputees. This study gives more insight into the use of vacuum-assisted socket systems to improve elderly transtibial dysvascular amputees' functionality and decrease their risk of falls. The use of an additional distal valve in the socket should be considered in patients with a lower activity level. © The International Society for Prosthetics and Orthotics 2014.
Seles, Maximilian; Gutschi, Thomas; Mayrhofer, Katrin; Fischereder, Katja; Ehrlich, Georg; Gallé, Guenter; Gutschi, Stefan; Pachernegg, Oliver; Pummer, Karl; Augustin, Herbert
2016-04-01
To evaluate whether biopsy cores taken via a transrectal approach from the anterior apical region of the prostate in a repeat-biopsy population can result in an increased overall cancer detection rate and in more accurate assessment of the Gleason score. The study was a prospective, randomised (end-fire vs side-fire ultrasound probe) evaluation of 288 men by repeat transrectal saturation biopsy with 28 cores taken from the transition zone, base, mid-lobar, anterior and the anterior apical region located ventro-laterally to the urethra of the peripheral zone. The overall prostate cancer detection rate was 44.4%. Improvement of the overall detection rate by 7.8% could be achieved with additional biopsies of the anterior apical region. Two tumours featuring a Gleason score 7 could only be detected in the anterior apical region. In three cases (2.34%) Gleason score upgrading was achieved by separate analysis of each positive core of the anterior apical region. A five-fold higher cancer detection rate in the anterior apical region compared with the transition zone could be shown. Sampling of the anterior apical region results in higher overall cancer detection rate in repeat transrectal saturation biopsies of the prostate. Specimens from this region can detect clinically significant cancer, improve accuracy of the Gleason Scoring and therefore may alter therapy. © 2015 The Authors BJU International © 2015 BJU International Published by John Wiley & Sons Ltd.
He, Qiqi; Wang, Hanzhang; Kenyon, Jonathan; Liu, Guiming; Yang, Li; Tian, Junqiang; Yue, Zhongjin; Wang, Zhiping
2015-01-01
To use meta-analysis to determine the accuracy of percutaneous core needle biopsy in the diagnosis of small renal masses (SMRs ≤ 4.0 cm). Studies were identified by searching PubMed, Embase, and the Cochrane Library database up to March 2013. Two of the authors independently assessed the study quality using QUADAS-2 tool and extracted data that met the inclusion criteria. The sensitivity, specificity, likelihood ratios, diagnostic odds ratio (DOR) and also summary receiver operating characteristic (SROC) curve were investigated and draw. Deek's funnel plot was used to evaluate the publication bias. A total of 9 studies with 788 patients (803 biopsies) were included. Failed biopsies without repeated or aborted from follow-up/surgery result were excluded (232 patients and 353 biopsies). For all cases, the pooled sensitivity was 94.0% (95% CI: 91.0%, 95.0%), the pooled positive likelihood was 22.57 (95 % CI: 9.20-55.34), the pooled negative likelihood was 0.09 (95 % CI: 0.06-0.13), the pooled DOR was 296.52(95 % CI: 99. 42-884.38). The area under the curve of SROC analysis was 0.959 ± 0.0254. Imaging-guided percutaneous core needle biopsy of small renal masses (SMRs ≤ 4.0 cm) is highly accurate to malignant tumor diagnosis with unknown metastatic status and could be offered to some patients after clinic judgment prior to surgical intervention consideration.
Jin, Byung-Soo; Kang, Seok-Hyun; Kim, Duk-Yoon; Oh, Hoon-Gyu; Kim, Chun-Il; Moon, Gi-Hak; Kwon, Tae-Gyun; Park, Jae-Shin
2015-09-01
To evaluate prospectively the role of prostate-specific antigen (PSA) density in predicting Gleason score upgrading in prostate cancer patients eligible for active surveillance (T1/T2, biopsy Gleason score≤6, PSA≤10 ng/mL, and ≤2 positive biopsy cores). Between January 2010 and November 2013, among patients who underwent greater than 10-core transrectal ultrasound-guided biopsy, 60 patients eligible for active surveillance underwent radical prostatectomy. By use of the modified Gleason criteria, the tumor grade of the surgical specimens was examined and compared with the biopsy results. Tumor upgrading occurred in 24 patients (40.0%). Extracapsular disease and positive surgical margins were found in 6 patients (10.0%) and 8 patients (17.30%), respectively. A statistically significant correlation between PSA density and postoperative upgrading was found (p=0.030); this was in contrast with the other studied parameters, which failed to reach significance, including PSA, prostate volume, number of biopsy cores, and number of positive cores. Tumor upgrading was also highly associated with extracapsular cancer extension (p=0.000). The estimated optimal cutoff value of PSA density was 0.13 ng/mL(2), obtained by receiver operating characteristic analysis (area under the curve=0.66; p=0.020; 95% confidence interval, 0.53-0.78). PSA density is a strong predictor of Gleason score upgrading after radical prostatectomy in patients eligible for active surveillance. Because tumor upgrading increases the potential for postoperative pathological adverse findings and prognosis, PSA density should be considered when treating and consulting patients eligible for active surveillance.
Risk factors for anal sphincter tears in vacuum-assisted delivery.
Ryman, P; Ahlberg, M; Ekéus, C
2015-10-01
The aim of the present study was to describe the prevalence of anal sphincter tears (AST) in relation to obstetric management and technique during vacuum extraction deliveries (VE) (re: indications, the station of the fetal head at application of the cup, number of tractions, the length for the extraction, cup detachments, pain relief, episiotomy, fetal presentation, and experience of the operator) as well as maternal and infant anthropometrics. Descriptive study. Data on six hundred vacuum extraction deliveries were consecutively collected from six different delivery units in Sweden. Each unit contributed with data on 100 deliveries. The final study population included 596 women who delivered by vacuum extraction. There was no correlation between the management of the vacuum extraction and risk for anal sphincter tear. Women from Africa had nearly a fourfold risk for anal sphincter tear during vacuum-assisted delivery compared with Swedish-born women (OR 3.82 CI 1.47-9.89). Compared with infants with birth weight less than 4000 g, birth weight above 4000 g was associated with increased risk of AST (OR 1.87 CI 1.06-3.28). In this study, the obstetric management in VE-assisted deliveries did not impact the risk of AST. Copyright © 2015 Elsevier B.V. All rights reserved.
Da Porto, Carla; Decorti, Deborha
2009-08-01
Ultrasonically assisted extraction of flavour compounds from different varieties of Mentha spicata, using 70% ethanol, have been carried out for 5, 10 and 15min and coupled with under vacuum distillation. The ultrasound distilled extracts have been analysed by GC-MS and compared with essential oils obtained by hydrodistillation. The results have showed that ultrasonically assisted extraction in combination with under vacuum distillation have provided extracts with higher flavouring strength due to the increased concentration of desirable oxygenated compounds (from 5 to 8 times) compared with hydrodistillation. Extraction yields of flavour volatiles have been calculated giving a range 0.04-0.13% by ultrasound and 0.01-0.02% by hydrodistillation.
Broadband infrared light emitting waveguides based on UV curable PbS quantum dot composites
NASA Astrophysics Data System (ADS)
Shen, Kai; Baig, Sarfaraz; Jiang, Guomin; Paik, Young-hun; Kim, Sung Jin; Wang, Michael R.
2018-02-01
We present herein the active PbS-photopolymer waveguide fabricated by vacuum assisted microfluidic (VAM) soft lithography technique. The PbS Quantum Dots (QDs) were synthesized using colloidal chemistry methods with tunable sizes and emission wavelengths, resulting in efficient light emission around 1000 nm center wavelength. The PbS QDs have demonstrated much better solubility in our newly synthesized UV curable polymer than SU-8 photoresist, verified by Photoluminescence (PL) testing. Through refractive index control, the PbS QDs-polymer core material and polymer cladding material can efficiently confine the infrared emitting light with a broad spectral bandwidth of 180 nm. Both single-mode and multi-mode light emitting waveguides have been realized.
Liu, Shuo; Lee, Stephen; Rashid, Prem; Bangash, Haider; Hamid, Akhlil; Lau, Jason; Cohen, Ronald
2016-10-01
To evaluate the intermediate outcome of conservative management in patients with biopsy-proven oncocytoma. Patients with oncocytoma diagnosed on percutaneous core biopsy between January 2000 to December 2014 were identified from the renal biopsy database of a large specialist urologic pathology laboratory. After review of patient clinical records, the study cohort comprised only of patients enrolled in active surveillance. Clinicopathological and follow-up details were reviewed for each case, in particular: type and interval of surveillance imaging, tumour growth, definitive intervention and reason for intervention. Where possible, correlation was made between the final surgical and the initial biopsy specimens. Fifty three patients diagnosed with oncocytoma on core biopsy were initially placed on active surveillance with median follow-up of 34 months (range 6-109). The median age at diagnosis was 65 years (range 20-85) and median tumour size was 30 mm (range 13-87). Mean average tumour growth was 1.4 mm per annum (median 0 mm/year) with the majority (36 of 53, 68%) exhibiting minimal growth (less than 2 mm per annum) or partial regression. Forty seven of the 53 patients remained on active surveillance with no significant progression. Six patients elected to undergo definitive intervention (five surgical excision, one ablation). Renal oncocytoma was confirmed in all five patients who underwent surgical excision of their lesions. The majority of oncocytomas in this study showed minimal growth rate or regression. Patients with biopsy proven oncocytoma can be conservatively managed with active surveillance. © 2016 The Authors BJU International © 2016 BJU International Published by John Wiley & Sons Ltd.
2014-01-01
Background Diagnosing adipocytic tumors can be challenging because it is often difficult to morphologically distinguish between benign, intermediate and malignant adipocytic tumors, and other sarcomas that are histologically similar. Recently, a number of tumor-specific chromosome translocations and associated fusion genes have been identified in adipocytic tumors and atypical lipomatous tumors/well-differentiated liposarcomas (ALT/WDL), which have a supernumerary ring and/or giant chromosome marker with amplified sequences of the MDM2 and CDK4 genes. The purpose of this study was to investigate whether quantitative real-time polymerase chain reaction (PCR) could be used to amplify MDM2 and CDK4 from total RNA samples obtained from core-needle biopsy sections for the diagnosis of ALT/WDL. Methods A series of lipoma (n = 124) and ALT/WDL (n = 44) cases were analyzed for cytogenetic analysis and lipoma fusion genes, as well as for MDM2 and CDK4 expression by real-time PCR. Moreover, the expression of MDM2 and CDK4 in whole tissue sections was compared with that in core-needle biopsy sections of the same tumor in order to determine whether real-time PCR could be used to distinguish ALT/WDL from lipoma at the preoperative stage. Results In whole tissue sections, the medians for MDM2 and CDK4 expression in ALT/WDL were higher than those in the lipomas (P < 0.05). Moreover, karyotype subdivisions with rings and/or giant chromosomes had higher MDM2 and CDK4 expression levels compared to karyotypes with 12q13-15 rearrangements, other abnormal karyotypes, and normal karyotypes (P < 0.05). On the other hand, MDM2 and CDK4 expression levels in core-needle biopsy sections were similar to those in whole-tissue sections (MDM2: P = 0.6, CDK4: P = 0.8, Wilcoxon signed-rank test). Conclusion Quantitative real-time PCR of total RNA can be used to evaluate the MDM2 and CDK4 expression levels in core-needle biopsies and may be useful for distinguishing ALT/WDL from adipocytic tumors. Thus, total RNA from core-needle biopsy sections may have potential as a routine diagnostic tool for other tumors where gene overexpression is a feature of the tumor. PMID:24965044
Shah, Rajal B; Bentley, James; Jeffery, Zach; DeMarzo, Angelo M
2015-05-01
ERG and PTEN biomarkers are increasingly being analyzed on prostate core biopsies (NBXs); ERG as a marker of clonality and number of separately arising tumor foci and PTEN for prognostic information. Yet, in patients with multiple biopsy cores positive for cancer (PCa), there is no standardized approach for interrogation of these biomarkers in terms of the number of positive cores to evaluate. A total of 194 NBX cases containing more than one positive core with cancer were evaluated for ERG overexpression and PTEN loss by immunostaining (immunohistochemistry) of all positive cores. ERG overexpression or PTEN loss in at least one cancer core was present in 111 (57%) and 69 (36%) cases respectively. ERG overexpression was significantly associated with PTEN loss (P < .0001), and PTEN loss was associated with a high Gleason score (P < .0001). Inter- and intra-tumor core staining heterogeneity for ERG overexpression occurred in 42% and 5% cases and for PTEN loss both intra- and inter-tumor core heterogeneity was 68%. PTEN staining was highly discordant between PCa sites regardless of laterality. When the Gleason score was non-uniform across PCa sites, the combination of cores showing the highest Gleason score and largest tumor volume provided the best representation of ERG overexpression (92%) and PTEN loss (98%). When grades were uniform across cancer sites, the highest tumor volume core was generally representative of ERG overexpression (90%) but was less representative for PTEN loss (76%). Our results suggest that knowledge of this heterogeneity is critical for developing optimal yet cost-effective strategies to identify these underlying molecular abnormalities. Copyright © 2015 Elsevier Inc. All rights reserved.
Cirla, A.; Rondena, M.; Bertolini, G.
2016-01-01
The purpose of this study was to evaluate the diagnostic value of imaging-guided core needle biopsy for canine orbital mass diagnosis. A second excisional biopsy obtained during surgery or necropsy was used as the reference standard. A prospective feasibility study was conducted in 23 canine orbital masses at a single centre. A complete ophthalmic examination was always followed by orbital ultrasound and computed tomography (CT) examination of the head. All masses were sampled with the patient still on the CT table using ultrasound (US) guided automatic tru-cut device. The most suitable sampling approach to the orbit was chosen each time based on the CT image analysis. One of the following different approaches was used: trans-orbital, trans-conjunctival or trans-masseteric. In all cases, the imaging-guided biopsy provided a sufficient amount of tissue for the histopathological diagnosis, which concurred with the biopsies obtained using the excisional technique. CT examination was essential for morphological diagnosis and provided detailed topographic information that allowed us to choose the safest orbital approach for the biopsy. US guided automatic tru-cut biopsy based on CT images, performed with patient still on the CT table, resulted in a minimally invasive, relatively easy, and accurate diagnostic procedure in dogs with orbital masses. PMID:27540512
Cirla, A; Rondena, M; Bertolini, G
2016-01-01
The purpose of this study was to evaluate the diagnostic value of imaging-guided core needle biopsy for canine orbital mass diagnosis. A second excisional biopsy obtained during surgery or necropsy was used as the reference standard. A prospective feasibility study was conducted in 23 canine orbital masses at a single centre. A complete ophthalmic examination was always followed by orbital ultrasound and computed tomography (CT) examination of the head. All masses were sampled with the patient still on the CT table using ultrasound (US) guided automatic tru-cut device. The most suitable sampling approach to the orbit was chosen each time based on the CT image analysis. One of the following different approaches was used: trans-orbital, trans-conjunctival or trans-masseteric. In all cases, the imaging-guided biopsy provided a sufficient amount of tissue for the histopathological diagnosis, which concurred with the biopsies obtained using the excisional technique. CT examination was essential for morphological diagnosis and provided detailed topographic information that allowed us to choose the safest orbital approach for the biopsy. US guided automatic tru-cut biopsy based on CT images, performed with patient still on the CT table, resulted in a minimally invasive, relatively easy, and accurate diagnostic procedure in dogs with orbital masses.
Atypia on breast core needle biopsies: reproducibility and significance.
Darvishian, Farbod; Singh, Baljit; Simsir, Aylin; Ye, Weimin; Cangiarella, Joan F
2009-01-01
This study analyzes the interobserver variability in interpreting atypia on breast core needle biopsies and in each category of atypia calculates the upgrade risk of carcinoma in the subsequent surgical excision. We identified 51 cases of atypia on breast core needle biopsies performed at our institution from January 2003 to August 2006. The atypia was classified into 4 categories: atypical ductal hyperplasia (ADH), atypical lobular hyperplasia (ALH), flat epithelial atypia (FEA), and atypia of undetermined significance (AUS). After a tutorial session, these cases were independently reviewed by four pathologists, whose overall multi-rater kappa value for agreement on different categories of atypia was 0.79 (95% CI, 0.69-0.89), which is within the substantial agreement range. The upgrade risk in each category of atypia was as follows: ADH 20% (p = 0.04); ALH 10% (p = 0.6); FEA 16.6% (p = 0.23), and AUS 100% (p = 0.96). Based on our findings, we conclude that follow-up excision should be performed after a diagnosis of ADH. The upgrade risk did not reach statistical significance in ALH or FEA. Although follow-up excision cannot be strongly recommended in ALH and FEA, it should be considered since the upgrade risk is not negligible. Strict adherence to the diagnostic criteria and tutorial sessions can help pathologists to achieve substantial agreement in interpreting atypia on breast core needle biopsies.
Rakha, Emad A; Pigera, Marian; Shin, Sandra J; D'Alfonso, Timothy; Ellis, Ian O; Lee, Andrew H S
2016-07-01
The recent American Society of Clinical Oncology/College of American Pathologists guidelines for human epidermal growth factor receptor 2 (HER2) testing in breast cancer recommend repeat testing based on tumour grade, tumour type, and hormone receptor status. The aim of this study was to test the value of these criteria. HER2 status was concordant in the core biopsies and excision specimens in 392 of 400 invasive carcinomas. The major reasons for discordance were amplification around the cut-off for positivity and tumour heterogeneity. Of 116 grade 3 carcinomas that were HER2-negative in the core biopsy, four were HER2-positive in the excision specimen. Three of these four either showed borderline negative amplification in the core biopsy or were heterogeneous. None of the 55 grade 1 carcinomas were HER2-positive. Review of repeat testing of HER2 in routine practice suggested that it may also be of value for multifocal tumours and if recommended by the person assessing the in-situ hybridization. Mandatory repeat HER2 testing of grade 3 HER2-negative carcinomas is not appropriate. This is particularly true if repeat testing is performed after borderline negative amplification in the core biopsy or in HER2-negative heterogeneous carcinomas. © 2015 John Wiley & Sons Ltd.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Thanos, Loukas; Galani, Panagiota, E-mail: paga@hol.gr; Mylona, Sophia
The purpose of this study was to determine the diagnostic value of percutaneous core needle biopsy (CNB) relative to fine needle aspiration (FNA) in patients with pneumonia and pneumonia mimics. In this prospective study we present our experience with 48 thoracic FNAs and CNBs carried out on 48 patients with pneumonia and pneumonia mimics. Samples were obtained from all patients using both CNB (with an automated 18-G core biopsy needle and a gun) and FNA (with a 22-G needle). A specific diagnosis was made in 10/48 cases (20.83%) by FNA and in 42/48 (87.5%) by CNB. The main complications encounteredmore » were pneumothorax (n = 4) and hemoptysis (n = 2), yielding a total complication rate of 12.5%. We concluded that CNB using an automated biopsy gun results in a higher diagnostic accuracy for pneumonia and pneumonia mimic biopsies than FNA. Complications should be considered and proper patient observation should follow the procedure.« less
Wu, Jennifer M; Williams, Kathryn S; Hundley, Andrew F; Connolly, AnnaMarie; Visco, Anthony G
2005-08-01
The purpose of this study was to determine whether an occiput posterior (OP) fetal head position increases the risk for anal sphincter injury when compared with an occiput anterior (OA) position in vacuum-assisted deliveries. We conducted a retrospective cohort study of 393 vacuum-assisted singleton vaginal deliveries. Maternal demographics and obstetric and neonatal data were collected from an obstetric database and chart review. Within the OP group, 41.7% developed a third- or fourth-degree laceration compared with 22.0% in the OA group (OR 2.5, 95% CI 1.4-4.7). In a logistic regression model that controlled for BMI, race, nulliparity, length of second stage, episiotomy, birth weight, head circumference, and fetal head position, OP position was 4.0 times (95% CI 1.7-9.6) more likely to be associated with an anal sphincter injury than OA position. Among vacuum deliveries, an OP head position confers an incrementally increased risk for anal sphincter injury over an OA position.
Self-assembly of core-shell structure PtO2@Pt nanodots and their formation evolution
NASA Astrophysics Data System (ADS)
Yang, Weijia; Liu, Junjie; Liu, Mingquan; Zhao, Zhicheng; Song, Yapeng; Tang, Xiufeng; Luo, Jianyi; Zeng, Qingguang; He, Xin
2018-05-01
Core-shell structure PtO2@Pt nanodots have been self-assembly by vacuum sputtering and high temperature annealing. First, Pt thin films with a small amount of PtO2 are grown on the sapphire substrates by vacuum sputtering. And then high temperature annealing on the thin films is carried out at 800 °C for 2 min to form Pt nanodots. During the cooling process, the atmosphere is deployed to supplant the nitrogen. Finally, even distributed core-shell structure PtO2@Pt nanodots with a diameter from 100 to 300 nm are achieved. Furthermore, the formation evolution of core-shell structure PtO2@Pt nanodots is also proposed. This work open up a new approach for fabricating core-shell structure nanodots.
Thoracic ultrasound-assisted selection for pleural biopsy with Abrams needle.
Botana-Rial, Maribel; Leiro-Fernández, Virginia; Represas-Represas, Cristina; González-Piñeiro, Ana; Tilve-Gómez, Amara; Fernández-Villar, Alberto
2013-11-01
Closed pleural biopsy (CPB) in patients with malignant pleural effusion is less sensitive than cytology. Ultrasound-assisted CPB allows biopsies to be performed in the lower thoracic parietal pleura, where secondary spread from pleural metastases is initially more likely to be found. We analyzed whether choosing the point of entry for CPB with thoracic ultrasound assistance influences the diagnostic yield in malignant pleural effusion. This prospective study included patients who underwent CPB performed by an experienced pulmonologist in 2008-2010 (group A) and thoracic ultrasound was used to select the biopsy site. The results were compared with a historical series of CPB performed by the same pulmonologist without the assistance of thoracic ultrasound (group B). An Abrams needle was used in all cases. We analyzed the obtaining of pleural tissue and the diagnostic yield. We included 114 CPBs from group A (23% tuberculous pleural effusion, 27% malignant pleural effusion) and 67 CPBs from group B (24% tuberculous pleural effusion, 30% malignant pleural effusion) (P = .70). Pleural tissue was obtained in 96.5% of the group A CPBs and 89.6% of the group B CPBs (P = .05). The diagnostic yields of CPB for tuberculous pleural effusion and malignant pleural effusion in group A were 89.5% and 77.4%, respectively, and 91.7% and 60%, respectively, in group B (P = .80 for tuberculous pleural effusion, and P = .18 for malignant pleural effusion). Selecting the point of entry for CPB using thoracic ultrasound increases the likelihood of obtaining pleural tissue and the diagnostic yield, but without statistical significance. We recommend ultrasound-assisted CPB to investigate pleural effusion, since the diagnostic yield of a pleural biopsy with an Abrams needle increased by > 17% in subjects with malignant pleural effusion.
Integrating machine learning and physician knowledge to improve the accuracy of breast biopsy.
Dutra, I; Nassif, H; Page, D; Shavlik, J; Strigel, R M; Wu, Y; Elezaby, M E; Burnside, E
2011-01-01
In this work we show that combining physician rules and machine learned rules may improve the performance of a classifier that predicts whether a breast cancer is missed on percutaneous, image-guided breast core needle biopsy (subsequently referred to as "breast core biopsy"). Specifically, we show how advice in the form of logical rules, derived by a sub-specialty, i.e. fellowship trained breast radiologists (subsequently referred to as "our physicians") can guide the search in an inductive logic programming system, and improve the performance of a learned classifier. Our dataset of 890 consecutive benign breast core biopsy results along with corresponding mammographic findings contains 94 cases that were deemed non-definitive by a multidisciplinary panel of physicians, from which 15 were upgraded to malignant disease at surgery. Our goal is to predict upgrade prospectively and avoid surgery in women who do not have breast cancer. Our results, some of which trended toward significance, show evidence that inductive logic programming may produce better results for this task than traditional propositional algorithms with default parameters. Moreover, we show that adding knowledge from our physicians into the learning process may improve the performance of the learned classifier trained only on data.
Grin, Andrea; O'Malley, Frances P; Mulligan, Anna Marie
2009-11-01
The presence of atypical or usual epithelial proliferations within papillary breast lesions complicates their interpretation on core biopsy. We evaluated the combination of estrogen receptor (ER) and cytokeratin 5 (CK5) as an aid in the distinction of usual duct hyperplasia from atypical proliferations in this setting. Core biopsies from 185 papillary lesions were reviewed and of these, 82 cases were selected for immunohistochemical study based on the presence of an epithelial proliferation between the fibrovascular cores. Fifty-two cases were used as the test set and 30 cases, with subsequent surgical excision, were used as the validation set. The epithelial proliferation was evaluated for staining intensity and percentage of positive cells using CK5 and ER. Expression of both CK5 and ER was significantly different in nonatypical lesions when compared with atypical lesions (P<0.0001). Nonatypical lesions typically showed an ER-low/CK5-high profile and atypical lesions showed an ER-high/CK5-low profile with ER-high expression defined as diffuse strong staining in >90% of cells. CK5-high expression was defined as a mosaic pattern of staining in >20% of cells and CK5-low as absent or staining in <20% of cells. On the basis of their staining profile, 29 of the 30 validation cases were correctly classified using the excision specimen as the gold standard. Patterns and extent of ER and CK5 staining, when used together, are valuable adjunct stains to differentiate usual duct hyperplasia from atypical proliferations within papillary lesions on core biopsy.
Proteomic analysis of formalin-fixed paraffin embedded tissue by MALDI imaging mass spectrometry
Casadonte, Rita; Caprioli, Richard M
2012-01-01
Archived formalin-fixed paraffin-embedded (FFPE) tissue collections represent a valuable informational resource for proteomic studies. Multiple FFPE core biopsies can be assembled in a single block to form tissue microarrays (TMAs). We describe a protocol for analyzing protein in FFPE -TMAs using matrix-assisted laser desorption/ionization (MAL DI) imaging mass spectrometry (IMS). The workflow incorporates an antigen retrieval step following deparaffinization, in situ trypsin digestion, matrix application and then mass spectrometry signal acquisition. The direct analysis of FFPE -TMA tissue using IMS allows direct analysis of multiple tissue samples in a single experiment without extraction and purification of proteins. The advantages of high speed and throughput, easy sample handling and excellent reproducibility make this technology a favorable approach for the proteomic analysis of clinical research cohorts with large sample numbers. For example, TMA analysis of 300 FFPE cores would typically require 6 h of total time through data acquisition, not including data analysis. PMID:22011652
Goenka, Ajit H; Remer, Erick M; Veniero, Joseph C; Thupili, Chakradhar R; Klein, Eric A
2015-09-01
The objective of our study was to review our experience with CT-guided transgluteal prostate biopsy in patients without rectal access. Twenty-one CT-guided transgluteal prostate biopsy procedures were performed in 16 men (mean age, 68 years; age range, 60-78 years) who were under conscious sedation. The mean prostate-specific antigen (PSA) value was 11.4 ng/mL (range, 2.3-39.4 ng/mL). Six had seven prior unsuccessful transperineal or transurethral biopsies. Biopsy results, complications, sedation time, and radiation dose were recorded. The mean PSA values and number of core specimens were compared between patients with malignant results and patients with nonmalignant results using the Student t test. The average procedural sedation time was 50.6 minutes (range, 15-90 minutes) (n = 20), and the mean effective radiation dose was 8.2 mSv (median, 6.6 mSv; range 3.6-19.3 mSv) (n = 13). Twenty of the 21 (95%) procedures were technically successful. The only complication was a single episode of gross hematuria and penile pain in one patient, which resolved spontaneously. Of 20 successful biopsies, 8 (40%) yielded adenocarcinoma (Gleason score: mean, 8; range, 7-9). Twelve biopsies yielded nonmalignant results (60%): high-grade prostatic intraepithelial neoplasia (n = 3) or benign prostatic tissue with or without inflammation (n = 9). Three patients had carcinoma diagnosed on subsequent biopsies (second biopsy, n = 2 patients; third biopsy, n = 1 patient). A malignant biopsy result was not significantly associated with the number of core specimens (p = 0.3) or the mean PSA value (p = 0.1). CT-guided transgluteal prostate biopsy is a safe and reliable technique for the systematic random sampling of the prostate in patients without a rectal access. In patients with initial negative biopsy results, repeat biopsy should be considered if there is a persistent rise in the PSA value.
Filippin, Alejandro Nicolas; Macias-Montero, Manuel; Saghi, Zineb; Idígoras, Jesús; Burdet, Pierre; Sanchez-Valencia, Juan R; Barranco, Angel; Migdley, Paul A; Anta, Juan A; Borras, Ana
2017-08-29
This paper addresses the fabrication of vertically aligned ZnO@TiO 2 multishell nanotubes by a combined full vacuum-plasma approach at mild temperatures. The growth is carried out within the premises of a one-reactor approach, i.e. minimizing the number of vacuum chambers and sample transferences. In this way, the interface between ZnO and TiO 2 is fully preserved from humidity thus increasing ZnO durability and stability. These nanostructures are studied by scanning electron microscopy (SEM), scanning transmission electron microscopy (STEM) and energy dispersive X-ray spectroscopy in STEM (EDX-STEM). High density one-dimensional arrays of these nanotubes formed on FTO substrates are applied as photoanode in a dye-sensitized solar cell (DSC). The evolution of the dye adsorption capacity and solar cells parameters are explored as a function of the crystallinity and thickness of the TiO 2 shell. The results show the critical effect of a full coverage by TiO 2 of ZnO core to explain the mixed results found in the literature.
Federal Register 2010, 2011, 2012, 2013, 2014
2013-11-07
... conducting this comparative effectiveness review pursuant to Section 1013 of the Medicare Prescription Drug... biopsy technique (each index test) will be quantified versus the reference standard \\b\\. The comparative...
NASA Astrophysics Data System (ADS)
Das, Ronnie; Burfeind, Chris W.; Lim, Saniel D.; Patle, Shubham; Seibel, Eric J.
2018-02-01
3D pathology is intrinsically dependent on 3D microscopy, or the whole tissue imaging of patient tissue biopsies (TBs). Consequently, unsectioned needle specimens must be processed whole: a procedure which cannot necessarily be accomplished through manual methods, or by retasking automated pathology machines. Thus "millifluidic" devices (for millimeter-scale biopsies) are an ideal solution for tissue handling/preparation. TBs are large, messy and a solid-liquid mixture; they vary in material, geometry and structure based on the organ biopsied, the clinician skill and the needle type used. As a result, traditional microfluidic devices are insufficient to handle such mm-sized samples and their associated fabrication techniques are impractical and costly with respect to time/efficiency. Our research group has devised a simple, rapid fabrication process for millifluidic devices using jointed skeletal molds composed of machined, reusable metal rods, segmented rods and stranded wire as structural cores; these cores are surrounded by Teflon outer housing. We can therefore produce curving, circular-cross-section (CCCS) millifluidic channels in rapid fashion that cannot normally be achieved by microfabrication, micro-/CNC-machining, or 3D printing. The approach has several advantages. CLINICAL: round channels interface coring needles. PROCESSING: CCCS channels permit multi-layer device designs for additional (processing, monitoring, testing) stages. REUSABILITY: for a biopsy/needle diameter, molding (interchangeable) components may be produced one-time then reused for other designs. RAPID: structural cores can be quickly removed due to Teflon®'s ultra-low friction; housing may be released with ethanol; PDMS volumes cure faster since metal skeleton molds conduct additional heat from within the curing elastomer.
Magnetic resonance imaging in prostate cancer detection and management: a systematic review.
Monni, Fabio; Fontanella, Paolo; Grasso, Angelica; Wiklund, Peter; Ou, Yen-Chuan; Randazzo, Marco; Rocco, Bernardo; Montanari, Emanuele; Bianchi, Giampaolo
2017-12-01
The aim of our work was to evaluate the role of multi-parametric magnetic resonance imaging (mpMRI) in detection and management of prostate cancer (PC); specifically investigating the efficacy of mpMRI-based biopsy techniques in terms of diagnostic yield of significant prostate neoplasm and the improved management of patients who choose conservative treatments or active surveillance. A systematic and critical analysis through Medline, Embase, Scopus and Web of Science databases was carried out in March 2016, following the PRISMA ("Preferred Reporting Items for Systematic Reviews and Meta-Analyses") statement. The search was conducted using the following key words: "MRI/TRUS-fusion biopsy," "PIRADS," "prostate cancer," "magnetic resonance imaging (MRI)," "multiparametric MRI (mpMRI)," "systematic prostate biopsy (SB)," "targeted prostate biopsy (TPB)." English language articles were reviewed for inclusion ability. Sixty-six studies were selected in order to evaluate the characteristics and limitations of traditional sample biopsy, the role of mpMRI in detection of PC, specifically the increased degree of diagnostic accuracy of targeted prostate biopsy compared to systematic biopsy (12 cores), and to transperineal saturation biopsies with trans-rectal ultrasound (TRUS) only. MpMRI can detect index lesions in approximately 90% of cases when compared to prostatectomy specimen. The diagnostic performance of biparametric MRI (T2w + DWI) is not inferior to mpMRI, offering valid options to diminish cost- and time-consumption. Since approximately 10% of significant lesions are still MRI-invisible, systematic cores biopsy seem to still be necessary. The analysis of the different techniques shows that in-bore MRI-guided biopsy and MRI/TRUS-fusion-guided biopsy are superior in detection of significant PC compared to visual estimation alone. MpMRI proved to be very effective in active surveillance, as it prevents underdetection of significant PC and it assesses low-risk disease accurately. In higher-risk disease, presurgical MRI may change the clinically-based surgical plan in up to a third of cases. Targeted prostate biopsy, guided by mpMRI, is able to improve diagnostic accuracy and to reduce the detection of insignificant PC. Since the negative predictive value (NPV) of mpMRI is still imperfect, systematic cores biopsy should not be omitted for optimal staging of disease. A process of a progressive and periodic evolution in the detection and radiological classification of prostate lesions (such as PIRADS), is still needed in patients in active surveillance and in radical prostatectomy planning.
Trejo Bittar, Humberto E; Doberer, Daniel; Mehrad, Mitra; Strollo, Diane C; Leader, Joseph K; Wenzel, Sally; Yousem, Samuel A
2017-02-01
The histologic changes occurring in severe/therapy-resistant asthma (SA) as defined by the European Respiratory Society/American Thoracic Society guidelines, particularly at the level of the distal airways are unknown. This study describes the clinical, radiologic, and histologic characteristics of 29 SA patients who underwent video-assisted thoracoscopic surgery lung biopsy. Pathologic observations were correlated with clinical features, especially the presence of autoimmune disease (AID) (15/29, 51.7%). Ten biopsies (10/29, 34.5%) showed only small airway manifestations of asthma, whereas in 19 (65.5%) asthmatic granulomatosis, manifested by asthmatic bronchiolitis supplemented by an alveolar septal mononuclear infiltrates with non-necrotizing granulomas, was present. SA patients without asthmatic granulomatosis showed more striking small airway injury, subbasement membrane thickening, and neutrophilic infiltrates. Cases with concurrent AID had a tendency to more parenchymal eosinophilic inflammation, more bronchiolocentric granulomas, and a suggestion of increased responsivity to nonsteroidal immunosuppressive therapy. Histologic examination of video-assisted thoracoscopic surgery lung biopsies in SA demonstrates diverse pathologies including cases associated with granulomatous inflammation in addition to eosinophilic infiltrates. This spectrum of histologies may link to a high incidence of AID.
Weinfurtner, R Jared; Patel, Bhavika; Laronga, Christine; Lee, Marie C; Falcon, Shannon L; Mooney, Blaise P; Yue, Binglin; Drukteinis, Jennifer S
2015-06-01
Analysis of magnetic resonance imaging-guided breast biopsies yielding high-risk histopathologic features at a single institution found an overall upstage rate to malignancy of 14% at surgical excision. All upstaged lesions were associated with atypical ductal hyperplasia. Flat epithelial atypia and atypical lobular hyperplasia alone or with lobular carcinoma in situ were not associated with an upstage to malignancy. The purpose of the present study w as to determine the malignancy upstage rates and imaging features of high-risk histopathologic findings resulting from magnetic resonance imaging (MRI)-guided core needle breast biopsies. These features include atypical ductal hyperplasia (ADH), atypical lobular hyperplasia (ALH), flat epithelial atypia (FEA), and lobular carcinoma in situ (LCIS). A retrospective medical record review was performed on all MRI-guided core needle breast biopsies at a single institution from June 1, 2007 to December 1, 2013 to select biopsies yielding high-risk histopathologic findings. The patient demographics, MRI lesion characteristics, and histopathologic features at biopsy and surgical excision were analyzed. A total of 257 MRI-guided biopsies had been performed, and 50 yielded high-risk histopathologic features (19%). Biopsy site and surgical excision site correlation was confirmed in 29 of 50 cases. Four of 29 lesions (14%) were upstaged: 1 case to invasive ductal carcinoma and 3 cases to ductal carcinoma in situ. ADH alone had an overall upstage rate of 7% (1 of 14), mixed ADH/ALH a rate of 75% (3 of 4), ALH alone or with LCIS a rate of 0% (0 of 7), and FEA a rate of 0% (0 of 4). Only mixed ADH/ALH had a statistically significant upstage rate to malignancy compared with the other high-risk histopathologic subtypes combined. No specific imaging characteristics on MRI were associated with an upstage to malignancy on the statistical analysis. MRI-guided breast biopsies yielding high-risk histopathologic features were associated with an overall upstage to malignancy rate of 14% at surgical excision. All upstaged lesions were associated with ADH. FEA and ALH alone or with LCIS were not associated with an upstage to malignancy. Copyright © 2015 Elsevier Inc. All rights reserved.
Radtke, Jan Philipp; Teber, Dogu; Hohenfellner, Markus
2015-01-01
Purpose Accurate detection of clinically significant prostate cancer (PC) and correct risk attribution are essential to individually counsel men with PC. Multiparametric MRI (mpMRI) facilitates correct localization of index lesions within the prostate and MRI-targeted prostate biopsy (TPB) helps to avoid the shortcomings of conventional biopsy such as false-negative results or underdiagnosis of aggressive PC. In this review we summarize the different sequences of mpMRI, characterize the possibilities of incorporating MRI in the biopsy workflow and outline the performance of targeted and systematic cores in significant cancer detection. Furthermore, we outline the potential of MRI in patients undergoing active surveillance (AS) and in the pre-operative setting. Materials and methods An electronic MEDLINE/PubMed search up to February 2015 was performed. English language articles were reviewed for inclusion ability and data were extracted, analyzed and summarized. Results Targeted biopsies significantly outperform conventional systematic biopsies in the detection of significant PC and are not inferior when compared to transperineal saturation biopsies. MpMRI can detect index lesions in app. 90% of cases as compared to prostatectomy specimen. The diagnostic performance of biparametric MRI (T2w + DWI) is not inferior to mpMRI, offering options to diminish cost- and time-consumption. Since app 10% of significant lesions are still MRI-invisible, systematic cores seem to be necessary. In-bore biopsy and MRI/TRUS-fusion-guided biopsy tend to be superior techniques compared to cognitive fusion. In AS, mpMRI avoids underdetection of significant PC and confirms low-risk disease accurately. In higher-risk disease, pre-surgical MRI can change the clinically-based surgical plan in up to a third of cases. Conclusions mpMRI and targeted biopsies are able to detect significant PC accurately and mitigate insignificant PC detection. As long as the negative predictive value (NPV) is still imperfect, systematic cores should not be omitted for optimal staging of disease. The potential to correctly classify aggressiveness of disease in AS patients and to guide and plan prostatectomy is evolving. PMID:26816833
NASA Technical Reports Server (NTRS)
Mohling, R.; Allen, M.; Baumgartner, R.
2006-01-01
Microsphere insulation panels (MIPs) have been developed as lightweight, longlasting replacements for the foam and vacuum-jacketed systems heretofore used for thermally insulating cryogenic vessels and transfer ducts. The microsphere core material of a typical MIP consists of hollow glass bubbles, which have a combination of advantageous mechanical, chemical, and thermal-insulation properties heretofore available only separately in different materials. In particular, a core filling of glass microspheres has high crush strength and low density, is noncombustible, and performs well in soft vacuum.
[Vacuum-assisted therapy for various wound types including diabetic foot ulcer].
Farah, Raymond; Gantus, Maher; Kogan, Leonid
2011-03-01
Vacuum is a noninvasive system that creates a localized controlled negative pressure environment. In this study, vacuum was provided by the V.A.C. Therapy system, which promotes wound healing by delayed primary or secondary intention through creating a moist wound environment, preparing the wound bed for closure, reducing edema, and promoting formation and perfusion of granulation tissue. Vacuum-assisted closure therapy is indicated for use in all care settings and for a variety of wound types including diabetic foot ulcers. The purpose of this study was to evaluate safety and clinical efficacy of negative pressure wound therapy (NPWT) compared with advanced moist wound therapy and standard treatment to treat foot ulcers in diabetic patients. This trial enrolled 43 patients; most of them were diabetic patients at any age with various skin ulcers and diabetic foot. These patients were divided into two groups, 17 patients were treated with vacuum and the 26 patients in the control group were treated with standard therapy including debridement. A greater proportion of foot and skin ulcers achieved complete ulcer closure with vacuum-assisted therapy p<0.001 compared with the standard therapy. Vacuum therapy significantly decreased the duration and frequency of admission p=0.032 and decreased the rate of amputation p<0.001. Results of our trial support other studies and demonstrate that vacuum is as safe as and more efficacious than standard therapy in the treatment of diabetic foot ulcers. A significantly greater number of patients achieved complete ulcer closure and granulation tissue formation with this therapy. The study group showed a significant reduction in the median time needed to heal ulcers, reduction of the number of admissions and amputation frequency.
Khan, Mishal; Hashmani, Farah Naz; Ahmed, Sajjad; Ahmed, Owais; Asim, Shabnam S; Wajahat, Yasmin; Sobani, Shoaib; Syed, Shershah; Qazi, Fahad
2015-02-01
Currently available vacuum devices used to assist women undergoing complicated labour are unsuitable for use in low-resource settings. The objective of this study was to evaluate the safety and feasibility of a new low-cost vacuum device, named Koohi Goth Vacuum Delivery System (KGVDS), designed for use in low-resource settings. A hospital-based, multicentre, prospective cohort study with no control group was conducted in Karachi, Pakistan. After training, KGVDS devices were made available for use by labour room staff at their discretion when instrumental delivery was indicated. Women to whom KGVDS was applied were followed from the start of labour until discharge. Feasibility was assessed in terms of successful expulsion of the foetal head following application of KGVDS and ease of use ratings. Safety was assessed by observing maternal and newborn post-delivery outcomes prior to discharge. Koohi Goth Vacuum Delivery System was applied to 137 women requiring instrumental delivery, of whom 111 (81%; 95% CI = 74-88%) successfully expelled the foetal head assisted by KGVDS and 103 (75%) stated that they would agree to use KGVDS again. There were no serious maternal or neonatal injuries or infections related to KGVDS use. The mean score for 'ease of use' given by doctors and midwives using the device was 8 of 10. Koohi Goth Vacuum Delivery System was feasible and safe to use for assisting complicated deliveries in low-resource hospitals in this initial evaluation. Our results indicate that this new device may have the potential to improve birth outcomes in settings where most mortality occurs and that further evaluations should be conducted. © 2014 John Wiley & Sons Ltd.
The significance of tumor heterogeneity for prediction of DNA ploidy of prostate cancer.
Häggarth, Lars; Auer, Gert; Busch, Christer; Norberg, Mona; Häggman, Michael; Egevad, Lars
2005-01-01
In a previous study, we mapped the ploidy heterogeneity of prostate cancer using flow cytometry in 676 tumor samples from 50 radical prostatectomy specimens. Ploidy heterogeneity was common (42% of tumors) and was found in all non-diploid tumors. The volume of non-diploid tumor was estimated and found to predict extra-prostatic extension and seminal vesicle invasion. The aim of this study was to evaluate the impact of tumor heterogeneity on preoperative ploidy assessment. In 50 men at least six core biopsies were taken before prostatectomy. Sections from biopsies with cancer were Feulgen-stained for image cytometry. After exclusion of biopsies with insufficient material, 123 histograms from 48 men (mean 2.6; range 1-7) remained for analysis. In 32 men, biopsies were diploid. In 16 men, at least one biopsy was non-diploid (14 tetraploid, two aneuploid) and 10 of them also had diploid biopsies. In 34 men (71%), the prostatectomy specimens were correctly predicted as being either diploid (48%) or non-diploid (23%). The sensitivity and specificity of biopsies for predicting non-diploid cancer were 55% and 82%, respectively, and the positive and negative predictive values were 69% and 72%, respectively. The ploidy status of tumors with and without ploidy heterogeneity was correctly predicted in 55% and 82% of cases, respectively (p=0.04). Biopsies underestimated ploidy in 9/20 tumors (45%) with heterogeneous ploidy status. Underestimation mainly occurred when one or two cores were analyzed. Preoperative prediction of the ploidy status of prostate cancer is hampered by tumor heterogeneity. Analysis of multiple biopsies is important for correct preoperative ploidy estimation.
Utilization of sentinel lymph node biopsy for uterine cancer.
Wright, Jason D; Cham, Stephanie; Chen, Ling; Burke, William M; Hou, June Y; Tergas, Ana I; Desai, Vrunda; Hu, Jim C; Ananth, Cande V; Neugut, Alfred I; Hershman, Dawn L
2017-06-01
To limit the potential short and long-term morbidity of lymphadenectomy, sentinel lymph node biopsy has been proposed for endometrial cancer. The principle of sentinel lymph node biopsy relies on removal of a small number of lymph nodes that are the first drainage basins from a tumor and thus the most likely to harbor tumor cells. While the procedure may reduce morbidity, efficacy data are limited and little is known about how commonly the procedure is performed. We examined the patterns and predictors of use of sentinel lymph node biopsy and outcomes of the procedure in women with endometrial cancer who underwent hysterectomy. We used the Perspective database to identify women with uterine cancer who underwent hysterectomy from 2011 through 2015. Billing and charge codes were used to classify women as having undergone lymphadenectomy, sentinel lymph node biopsy, or no nodal assessment. Multivariable models were used to examine clinical, demographic, and hospital characteristics with use of sentinel lymph node biopsy. Length of stay and cost were compared among the different methods of nodal assessment. Among 28,362 patients, 9327 (32.9%) did not undergo nodal assessment, 17,669 (62.3%) underwent lymphadenectomy, and 1366 (4.8%) underwent sentinel lymph node biopsy. Sentinel lymph node biopsy was performed in 1.3% (95% confidence interval, 1.0-1.6%) of abdominal hysterectomies, 3.4% (95% confidence interval, 2.7-4.1%) of laparoscopic hysterectomies, and 7.5% (95% confidence interval, 7.0-8.0%) of robotic-assisted hysterectomies. In a multivariable model, more recent year of surgery was associated with performance of sentinel lymph node biopsy. Compared to abdominal hysterectomy, those undergoing laparoscopic (adjusted risk ratio, 2.45; 95% confidence interval, 1.89-3.18) and robotic-assisted (adjusted risk ratio, 2.69; 95% confidence interval, 2.19-3.30) hysterectomy were more likely to undergo sentinel lymph node biopsy. Among women who underwent minimally invasive hysterectomy, length of stay and cost were lower for sentinel lymph node biopsy compared to lymphadenectomy. The use of sentinel lymph node biopsy for endometrial cancer increased from 2011 through 2015. The increased use was most notable in women who underwent a robotic-assisted hysterectomy. Copyright © 2017 Elsevier Inc. All rights reserved.
Papillary lesions of the breast: To excise or observe?
Khan, Sidrah; Diaz, Adrian; Archer, Kellie J; Lehman, Rebecca R; Mullins, Tiffany; Cardenosa, Gilda; Bear, Harry D
2018-05-01
Papillary lesions of the breast range from benign to atypical to malignant. Although papillomas without frank cancer are benign, their management remains controversial. When a core needle biopsy of a lesion yields a diagnosis of intraductal papilloma with atypia, excision is generally recommended to rule out a concurrent malignant neoplasm. For intraductal papillomas without atypia, however, recommendations for excision versus observation are variable. The aims of this study are to evaluate the rate of concurrent malignancies for intraductal papilloma diagnosed on core needle biopsy and to assess the long-term risk of developing cancer after the diagnosis of a papillary lesion. This single institution retrospective study analyzed 259 patients that were diagnosed with intraductal papilloma (IDP) by core needle biopsy from 1995 to 2010. Patients were grouped by initial diagnosis into three groups (papilloma without atypia, papilloma with atypia, and papilloma with atypical duct hyperplasia or atypical lobular hyperplasia (ADH/ALH) and followed up for long-term outcomes. After a core needle biopsy showing IDP with atypia or IDP + ADH/ALH, surgical excision yielded a diagnosis of concomitant invasive or ductal in situ cancer in greater that 30% of cases. For intraductal papilloma without atypia, the likelihood of cancer was much lower. Moreover, even with excision, the finding of intraductal papilloma with atypia carries a significant risk of developing cancer long-term, and such patients should be followed carefully and perhaps should be considered for chemoprevention. © 2017 Wiley Periodicals, Inc.
[Variations in the diagnostic confirmation process between breast cancer mass screening units].
Natal, Carmen; Fernández-Somoano, Ana; Torá-Rocamora, Isabel; Tardón, Adonina; Castells, Xavier
2016-01-01
To analyse variations in the diagnostic confirmation process between screening units, variations in the outcome of each episode and the relationship between the use of the different diagnostic confirmation tests and the lesion detection rate. Observational study of variability of the standardised use of diagnostic and lesion detection tests in 34 breast cancer mass screening units participating in early-detection programmes in three Spanish regions from 2002-2011. The diagnostic test variation ratio in percentiles 25-75 ranged from 1.68 (further appointments) to 3.39 (fine-needle aspiration). The variation ratio in detection rates of benign lesions, ductal carcinoma in situ and invasive cancer were 2.79, 1.99 and 1.36, respectively. A positive relationship between rates of testing and detection rates was found with fine-needle aspiration-benign lesions (R(2): 0.53), fine-needle aspiration-invasive carcinoma (R(2): 0 28), core biopsy-benign lesions (R(2): 0.64), core biopsy-ductal carcinoma in situ (R(2): 0.61) and core biopsy-invasive carcinoma (R(2): 0.48). Variation in the use of invasive tests between the breast cancer screening units participating in early-detection programmes was found to be significantly higher than variations in lesion detection. Units which conducted more fine-needle aspiration tests had higher benign lesion detection rates, while units that conducted more core biopsies detected more benign lesions and cancer. Copyright © 2016 SESPAS. Published by Elsevier Espana. All rights reserved.
Salemis, Nikolaos S; Vasilara, Georgia; Lagoudianakis, Emmanuel
2015-01-01
Mondor's disease is a rare benign and self-limiting condition characterized by thrombophlebitis of the superficial veins of the anterolateral thoracoabdominal wall. We describe a case of Mondor's disease of the breast as a complication of an ultrasound-guided core needle biospy. The patient presented with a palpable cord-like structure in her left breast, associated with severe pain and tenderness. She was treated concervatively and complete resolution was observed after four weeks. We conclude that emergency clinicians and interventional breast radiologists should be aware of Mondor's disease as a potential complication of ultrasound-guided core needle biopsy of the breast.
López Ruiz, J A; Zabalza Estévez, I; Mieza Arana, J A
2016-01-01
To evaluate the possibility of determining the genetic profile of primary malignant tumors of the breast from specimens obtained by ultrasound-guided percutaneous biopsies during the diagnostic imaging workup. This is a retrospective study in 13 consecutive patients diagnosed with invasive breast cancer by B-mode ultrasound-guided 12 G core needle biopsy. After clinical indication, the pathologist decided whether the paraffin block specimens seemed suitable (on the basis of tumor size, validity of the sample, and percentage of tumor cells) before sending them for genetic analysis with the MammaPrint® platform. The size of the tumors on ultrasound ranged from 0.6cm to 5cm. In 11 patients the preserved specimen was considered valid and suitable for use in determining the genetic profile. In 1 patient (with a 1cm tumor) the pathologist decided that it was necessary to repeat the core biopsy to obtain additional samples. In 1 patient (with a 5cm tumor) the specimen was not considered valid by the genetic laboratory. The percentage of tumor cells in the samples ranged from 60% to 70%. In 11/13 cases (84.62%) it was possible to do the genetic analysis on the previously diagnosed samples. In most cases, regardless of tumor size, it is possible to obtain the genetic profile from tissue specimens obtained with ultrasound-guided 12 G core biopsy preserved in paraffin blocks. Copyright © 2015 SERAM. Published by Elsevier España, S.L.U. All rights reserved.
Inaga, Sumire; Kato, Masako; Hirashima, Sayuri; Munemura, Chishio; Okada, Sinichi; Kameie, Toshio; Katsumoto, Tetsuo; Nakane, Hironobu; Tanaka, Keiichi; Hayashi, Kazuhiko; Naguro, Tomonori
2010-01-01
Renal biopsy paraffin sections were examined by low vacuum scanning electron microscopy (LVSEM) in the backscattered electron (BSE) mode, a novel method for rapid pathological analysis which allowed detailed and efficient three-dimensional observations of glomeruli. Renal samples that had been already diagnosed by light microscopy (LM) as exhibiting IgA nephropathy, minor glomerular abnormalities, and membranous glomerulonephritis (GN) were rapidly processed in the present study. Unstained paraffin sections of biopsy samples on glass slides were deparaffinized, stained with platinum blue (Pt-blue) or periodic acid silver-methenamine (PAM), and directly observed with a LVSEM. Overviews of whole sections and detailed observations of individual glomeruli were immediately performed at arbitrary magnifications between ×50 to ×18,000. Cut surface views and surface views of glomeruli were demonstrated at the same time. On Pt-blue-stained sections, podocytes, endothelia, mesangium, and glomerular basement membranes (GBMs) could be distinguished due to the different yields of BSE signals, and pathological features were investigated in every sample. The abnormal surface appearances of podocytes with foot processes and the varying thicknesses of GBM were revealed three-dimensionally, features difficult to observe under LM and transmission electron microscopy. PAM-positive GBM alterations in membranous GN were distinctly visualized through overlying cells without cell removal under LVSEM at high magnification. Not only prominent spike formation but also slight protrusions were clearly revealed in the side views of GBM. Crater-like or hole-like structures were shown in the en face views of GBM. Accordingly, LVSEM is expected to provide a novel approach to the pathological diagnosis of human glomerular diseases using conventional renal biopsy sections.
Kammerer-Jacquet, Solene-Florence; Compérat, Eva; Egevad, Lars; Hes, Ondra; Oxley, Jon; Varma, Murali; Kristiansen, Glen; Berney, Daniel M
2018-04-01
Transperineal template prostate biopsies (TTPB) are performed for assessments after unexpected negative transrectal ultrasound biopsies (TRUSB), correlation with imaging findings and during active surveillance. The impact of TTPBs on pathology has not been analysed. The European Network of Uropathology (ENUP) distributed a survey on TTPB, including how specimens were received, processed and analysed. Two hundred forty-four replies were received from 22 countries with TTPBs seen by 68.4% of the responders (n = 167). Biopsies were received in more than 12 pots in 35.2%. The number of cores embedded per cassette varied between 1 (39.5%) and 3 or more (39.5%). Three levels were cut in 48.3%, between 2 and 3 serial sections in 57.2% and unstained spare sections in 45.1%. No statistical difference was observed with TRUSB management. The number of positive cores was always reported and the majority gave extent per core (82.3%), per region (67.1%) and greatest involvement per core (69.4%). Total involvement in the whole series and continuous/discontinuous infiltrates were reported in 42.2 and 45.4%, respectively. The majority (79.4%) reported Gleason score in each site or core, and 59.6% gave an overall score. A minority (28.5%) provided a map or a diagram. For 19%, TTPB had adversely affected laboratory workload with only 27% managing to negotiate extra costs. Most laboratories process samples thoroughly and report TTPB similarly to TRUSB. Although TTPB have caused considerable extra work, it remains uncosted in most centres. Guidance is needed for workload impact and minimum standards of processing if TTPB work continues to increase.
Chen, Hua-Jun; Yang, Jin-Ji; Fang, Liang-Yi; Huang, Min-Min; Yan, Hong-Hong; Zhang, Xu-Chao; Xu, Chong-Rui; Wu, Yi-Long
2014-03-01
A satisfactory biopsy determines the state-of-the-art management of lung cancer in this era of personalized medicine. This study aimed to investigate the suitability and efficacy of computed tomography (CT)-guided core needle biopsy in clinical management. A cohort of 353 patients with clinically suspected lung cancer was enrolled in the study. Patient factors and biopsy variables were recorded. Epidermal growth factor receptor (EGFR) gene mutations and echinoderm microtubule-associated protein-like 4 (EML4)-anaplastic lymphoma kinase (ALK) rearrangement were detected in tumor specimens. Adequacy of biopsic obtainment for clinical trial screening and tissue bank establishment were reviewed. Overall diagnostic accuracy of malignancy achieved 98.5%. The median biopsy time of the cohort was 20 minutes. In patients with non-small cell lung cancer (NSCLC), 99.3% (287/289) were diagnosed as specific histologic subtypes, and two patients (0.7%) were determined as NSCLC not otherwise specified (NOS). EGFR mutations were analyzed in 81.7% (236/289) of patients with NSCLC, and 98.7% (233/236) showed conclusive results. EML4-ALK gene fusion was tested in 43.9% (127/289) of NSCLC patients, and 98.4% (125/127) showed conclusive results: 6.4% (8/125) of those had gene fusion. Ninety-six NSCLC patients participated in clinical trial screening and provided mandatory tumor slides for molecular profiling. Pathological evaluation was fulfilled in 90 patients (93.8%); 99.4% (320/322) of patients with malignancy provided extra tissue for the establishment of a tumor bank. CT-guided core needle biopsy provided optimal clinical management in this era of translational medicine. The biopsic modality should be prioritized in selected lung cancer patients.
Chen, Hua-Jun; Yang, Jin-Ji; Fang, Liang-Yi; Huang, Min-Min; Yan, Hong-Hong; Zhang, Xu-Chao; Xu, Chong-Rui; Wu, Yi-Long
2014-01-01
Background A satisfactory biopsy determines the state-of-the-art management of lung cancer in this era of personalized medicine. This study aimed to investigate the suitability and efficacy of computed tomography (CT)-guided core needle biopsy in clinical management. Methods A cohort of 353 patients with clinically suspected lung cancer was enrolled in the study. Patient factors and biopsy variables were recorded. Epidermal growth factor receptor (EGFR) gene mutations and echinoderm microtubule-associated protein-like 4 (EML4)-anaplastic lymphoma kinase (ALK) rearrangement were detected in tumor specimens. Adequacy of biopsic obtainment for clinical trial screening and tissue bank establishment were reviewed. Results Overall diagnostic accuracy of malignancy achieved 98.5%. The median biopsy time of the cohort was 20 minutes. In patients with non-small cell lung cancer (NSCLC), 99.3% (287/289) were diagnosed as specific histologic subtypes, and two patients (0.7%) were determined as NSCLC not otherwise specified (NOS). EGFR mutations were analyzed in 81.7% (236/289) of patients with NSCLC, and 98.7% (233/236) showed conclusive results. EML4-ALK gene fusion was tested in 43.9% (127/289) of NSCLC patients, and 98.4% (125/127) showed conclusive results: 6.4% (8/125) of those had gene fusion. Ninety-six NSCLC patients participated in clinical trial screening and provided mandatory tumor slides for molecular profiling. Pathological evaluation was fulfilled in 90 patients (93.8%); 99.4% (320/322) of patients with malignancy provided extra tissue for the establishment of a tumor bank. Conclusions CT-guided core needle biopsy provided optimal clinical management in this era of translational medicine. The biopsic modality should be prioritized in selected lung cancer patients. PMID:26766993
Wagner, Jason M; Conrad, Rachel D; Cannon, Trinitia Y; Alleman, Anthony M
2016-05-01
Limited data exist regarding the feasibility of ultrasound-guided transcutaneous biopsy of the base of the tongue and floor of the mouth. This retrospective study reviewed 8 cases with lesions in the base of the tongue or floor of the mouth that were biopsied by fine-needle aspiration. Core biopsy was also needed in 1 case. All biopsies were technically successful, and all yielded squamous cell carcinoma. One biopsy yielded a false-positive result, as subsequent resection yielded high-grade dysplasia with no invasion. The other biopsy results were considered true-positive based on subsequent pathologic examinations (2 cases) or clinical/imaging follow-up (5 cases). There were no significant complications associated with the biopsies. © 2016 by the American Institute of Ultrasound in Medicine.
Biopsy Findings After Breast Conservation Therapy for Early-Stage Invasive Breast Cancer
DOE Office of Scientific and Technical Information (OSTI.GOV)
Vapiwala, Neha; Starzyk, Jill; Harris, Eleanor E.
2007-10-01
Purpose: To determine the patterns and factors predictive of positive ipsilateral breast biopsy after conservation therapy for early-stage breast cancer. Methods and Materials: We performed a retrospective review of Stage I-II breast cancer patients initially treated with lumpectomy and radiotherapy between 1977 and 1996, who later underwent post-treatment ipsilateral breast biopsies. Results: A total of 223 biopsies were performed in 193 treated breasts: 171 single and 22 multiple biopsies. Of the 223 biopsies, 56% were positive and 44% were negative for recurrence. The positive biopsy rate (PBR) was 59% for the first and 32% for subsequent biopsies. The median timemore » to the first post-treatment biopsy was 49 months. Of the patients with negative initial biopsy findings, 11% later developed local recurrence. The PBR was 40% among patients with physical examination findings only, 65% with mammographic abnormalities only, and 79% with both findings (p = 0.001). Analysis of the procedure type revealed a PBR of 86% for core and 58% for excisional biopsies compared with 28% for aspiration cytology alone (p = 0.025). The PBR varied inversely with age at the original diagnosis: 49% if {>=}51 years, 57% if 36-50 years, and 83% if {<=}35 years (p = 0.05). The PBR correlated directly with the interval after radiotherapy: 49% if {<=}60 months, 59% if 60.1-120 months, 77% if 120.1-180 months, and 100% if >180 months after completing postlumpectomy radiotherapy (p = 0.01). The PBR was not linked with recurrence location, initial pathologic T or N stage, estrogen receptor/progesterone receptor status, or final pathologic margins (all p {>=} 0.15). Conclusion: After definitive radiotherapy for early-stage breast cancer, a greater PBR was associated with the presence of both mammographic and clinical abnormalities, excisional or core biopsies, younger age at the initial diagnosis, and longer intervals after radiotherapy completion.« less
David, N; Labbe-Devilliers, C; Moreau, D; Loussouarn, D; Campion, L
2006-11-01
FEA lesions group two histological types: columnar cell hyperplasia with atypia (CCHA) and columnar cell change with atypia (CCA). The increasing use of VAB has resulted in increased detection of isolated FEA lesions. The aim of this study was to define the best management possible for these patients: which cases may not need excision? From our database of 780 VABs carried out from 2000 to 2004, 59 patients with FEA were diagnosed. Cases in which no surgery was performed or all features were not available were excluded, thus excluding 19 cases. Forty patients with FEA were included. We reviewed clinical and mammographic characteristics, histological biopsy, and the corresponding surgically excised tissue features. VAB yielded 25 cases of CCHA and 15 cases of CCA. Surgery revealed seven ductal carcinoma cases (four invasive, three in situ); nine benign lesions, and 24 with atypia (19 FEA and six atypical ductal hyperplasia). We found two features related to the risk of cancer: the presence and the size of hyperplasia. All carcinomas were found within the CCHA lesions. No cancer was yielded when size was less than 10 mm within CCA lesions and lesions that were totally removed. We recommend surgical excision when CCHA greater than 10 mm is found on the VAB or it is incompletely removed. CCA lesions or CCHA less than 10 mm or totally removed may obviate systematic surgery.
Do breast columnar cell lesions with atypia need to be excised?
Datrice, Nicole; Narula, Navneet; Maggard, Melinda; Butler, John; Hsiang, David; Baick, Choong; Lane, Karen
2007-10-01
Columnar cell lesion with atypia (CCLA) is a newly recognized pathologic entity seen in breast specimens. The breast cancer risk associated with this finding is unclear, although CCLA had been found adjacent to both in situ and invasive carcinomas, but the incidence is unknown. Breast specimens from patients with a columnar cell lesion were reviewed by a pathologist for atypia. Twenty-one specimens with CCLA were identified [core biopsy (8), excisional biopsy (11), and simple mastectomy (2)]. Six of eight specimens with CCLA on core had adjacent abnormal pathology: infiltrating ductal carcinoma (IDC)/lobular carcinoma in situ (LCIS) (1), ductal carcinoma in situ (DCIS)/LCIS (1), DCIS (1), LCIS (1), and papillomatosis (2). Five of 11 specimens with CCLA on excisional biopsy had adjacent abnormal pathology: IDC (3), DCIS/LCIS (1), and atypical ductal hyperplasia/papilloma (1). Two of two simple mastectomy specimens had CCLA associated with IDC (1) and DCIS (1). Overall, abnormal pathology was found adjacent to CCLA in 62 per cent of specimens (13/21). Breast pathologic specimens containing a columnar cell lesion should be carefully examined for atypia. Surgical excision is warranted for CCLA found on core biopsy. The future risk of breast cancer based on the finding of CCLA alone requires further investigation.
... Lung tissue removal; Pneumonectomy; Lobectomy; Lung biopsy; Thoracoscopy; Video-assisted thoracoscopic surgery; VATS ... do surgery on your lungs are thoracotomy and video-assisted thoracoscopic surgery (VATS). Robotic surgery may also ...
Psoriasis skin biopsy image segmentation using Deep Convolutional Neural Network.
Pal, Anabik; Garain, Utpal; Chandra, Aditi; Chatterjee, Raghunath; Senapati, Swapan
2018-06-01
Development of machine assisted tools for automatic analysis of psoriasis skin biopsy image plays an important role in clinical assistance. Development of automatic approach for accurate segmentation of psoriasis skin biopsy image is the initial prerequisite for developing such system. However, the complex cellular structure, presence of imaging artifacts, uneven staining variation make the task challenging. This paper presents a pioneering attempt for automatic segmentation of psoriasis skin biopsy images. Several deep neural architectures are tried for segmenting psoriasis skin biopsy images. Deep models are used for classifying the super-pixels generated by Simple Linear Iterative Clustering (SLIC) and the segmentation performance of these architectures is compared with the traditional hand-crafted feature based classifiers built on popularly used classifiers like K-Nearest Neighbor (KNN), Support Vector Machine (SVM) and Random Forest (RF). A U-shaped Fully Convolutional Neural Network (FCN) is also used in an end to end learning fashion where input is the original color image and the output is the segmentation class map for the skin layers. An annotated real psoriasis skin biopsy image data set of ninety (90) images is developed and used for this research. The segmentation performance is evaluated with two metrics namely, Jaccard's Coefficient (JC) and the Ratio of Correct Pixel Classification (RCPC) accuracy. The experimental results show that the CNN based approaches outperform the traditional hand-crafted feature based classification approaches. The present research shows that practical system can be developed for machine assisted analysis of psoriasis disease. Copyright © 2018 Elsevier B.V. All rights reserved.
Lee, Daniel J; Recabal, Pedro; Sjoberg, Daniel D; Thong, Alan; Lee, Justin K; Eastham, James A; Scardino, Peter T; Vargas, Hebert Alberto; Coleman, Jonathan; Ehdaie, Behfar
2016-09-01
We compared the diagnostic outcomes of magnetic resonance-ultrasound fusion and visually targeted biopsy for targeting regions of interest on prostate multiparametric magnetic resonance imaging. Patients presenting for prostate biopsy with regions of interest on multiparametric magnetic resonance imaging underwent magnetic resonance imaging targeted biopsy. For each region of interest 2 visually targeted cores were obtained, followed by 2 cores using a magnetic resonance-ultrasound fusion device. Our primary end point was the difference in the detection of high grade (Gleason 7 or greater) and any grade cancer between visually targeted and magnetic resonance-ultrasound fusion, investigated using McNemar's method. Secondary end points were the difference in detection rate by biopsy location using a logistic regression model and the difference in median cancer length using the Wilcoxon signed rank test. We identified 396 regions of interest in 286 men. The difference in the detection of high grade cancer between magnetic resonance-ultrasound fusion biopsy and visually targeted biopsy was -1.4% (95% CI -6.4 to 3.6, p=0.6) and for any grade cancer the difference was 3.5% (95% CI -1.9 to 8.9, p=0.2). Median cancer length detected by magnetic resonance-ultrasound fusion and visually targeted biopsy was 5.5 vs 5.8 mm, respectively (p=0.8). Magnetic resonance-ultrasound fusion biopsy detected 15% more cancers in the transition zone (p=0.046) and visually targeted biopsy detected 11% more high grade cancer at the prostate base (p=0.005). Only 52% of all high grade cancers were detected by both techniques. We found no evidence of a significant difference in the detection of high grade or any grade cancer between visually targeted and magnetic resonance-ultrasound fusion biopsy. However, the performance of each technique varied in specific biopsy locations and the outcomes of both techniques were complementary. Combining visually targeted biopsy and magnetic resonance-ultrasound fusion biopsy may optimize the detection of prostate cancer. Copyright © 2016 American Urological Association Education and Research, Inc. Published by Elsevier Inc. All rights reserved.
Hernández, José Arias; Franco, María Eugenia Lozano; Mendizábal, David Pablo Bulnes; Broca, Yrma Bocanegra; Escoto, Adrián Fores
2009-11-01
To compare endometrial biopsy by hysteroscopy vs manual endouterine aspiration in office, in patients of Climateric Clinic from Hospital Regional de Alta Especialidad de la Mujer Tabasco, with postmenopausal uterine bleeding. There were included patients that come from October 30 2007 to December 20 2008 to Climateric Clinic, with abnormal uterine bleeding and without hormonal replacement therapy. There were taken biopsy by hysteroscopy and AMEU. The histopathology results were compared. A total of 25 women were evaluated. The average age was 53 years (+/- 5.6). The delivery average was 3 births (+/- 1). We found polyps in 9 (37%) patients, endometrial atrophy in 3 (13%), cystic hyperplasia in 2 (8%), proliferative endometrium in 4 (17%), submucous myomas in 5 (21%) and neoplasia in 1 (4%). The correlation between endometrial biopsy by hysteroscopy and AMEU was 100% for endometrial atrophy, cystic hyperplasia, proliferativo endometrium and neoplasia. There was not correlation between manual endouterine aspiration and endometrial biopsy by hysteroscopy for polyps and submucous myomas. We didn't have complications during the procedures. Hysteroscopic endometrial biopsy seems to have the same histopathology results than AMEU for endometrial atrophy, cystic hyperplasia, proliferative endometrium and neoplasia, not for miomas and polyps. Hysteroscopy can give us the possibility to see miomas and polyps and treat surgical pathology at the same moment almost in all cases.
Inutan, Ellen D.; Trimpin, Sarah
2013-01-01
The introduction of electrospray ionization (ESI) and matrix-assisted laser desorption/ionization (MALDI) for the mass spectrometric analysis of peptides and proteins had a dramatic impact on biological science. We now report that a wide variety of compounds, including peptides, proteins, and protein complexes, are transported directly from a solid-state small molecule matrix to gas-phase ions when placed into the vacuum of a mass spectrometer without the use of high voltage, a laser, or added heat. This ionization process produces ions having charge states similar to ESI, making the method applicable for high performance mass spectrometers designed for atmospheric pressure ionization. We demonstrate highly sensitive ionization using intermediate pressure MALDI and modified ESI sources. This matrix and vacuum assisted soft ionization method is suitable for the direct surface analysis of biological materials, including tissue, via mass spectrometry. PMID:23242551
Yield of Routine Image-Guided Biopsy of Renal Mass Thermal Ablation Zones: 11-Year Experience.
Wasnik, Ashish P; Higgins, Ellen J; Fox, Giovanna A; Caoili, Elaine M; Davenport, Matthew S
2018-06-19
To determine the yield of routine image-guided core biopsy of renal cell carcinoma (RCC) thermal ablation zones. Institutional review board approval was obtained for this Health Insurance Portability and Accountability Act-compliant quality improvement effort. Routine core biopsy of RCC ablation zones was performed 2 months postablation from July 2003 to December 2014. Routine nicotinamide adenine dinucleotide staining was performed by specialized genitourinary pathologists to assess cell viability. The original purpose of performing routine postablation biopsy was to verify, in addition to imaging, whether the mass was completely treated. Imaging was stratified as negative, indeterminate, or positive for viable malignancy. Histology was stratified as negative, indeterminate, positive, or nondiagnostic for viable malignancy. Histology results were compared to prebiopsy imaging findings. Routine ablation zone biopsy was performed after 50% (146/292) of index ablations (24 cryoablations, 122 radiofrequency ablations), and postablation imaging was performed more often with multiphasic computed tomography than magnetic resonance imaging (100 vs 46, p < 0.0001). When imaging was negative (n = 117), biopsy added no additional information (92% [n = 108] negative, 0.9% [n = 1] indeterminate, 7% [n = 8] nondiagnostic). When imaging was indeterminate (n = 19), 11% (n = 2) of biopsies had viable RCC and 89% (n = 17) were negative. When imaging was positive, biopsy detected viable neoplasm in only 10% (1/10) of cases; 80% (8/10) were negative and 10% (1/10) were nondiagnostic. Routine biopsy of renal ablation zones to validate postablation imaging results was not value-added and therefore was discontinued at the study institution. Copyright © 2018. Published by Elsevier Inc.
Ebner, Martina; Mariacher, Siegfried; Januschowski, Kai; Boden, Katrin; Seuthe, Anna-Maria; Szurman, Peter; Boden, Karl Thomas
2017-08-01
To evaluate intraocular pressure (IOP) using the application of a novel liquid patient interface for femtosecond laser-assisted cataract surgery with the FEMTO LDV Z8. IOP was evaluated in enucleated porcine eyes prior, during and after the application of the Femto LDV Z8 liquid patient interface (Ziemer Ophthalmic Systems, Switzerland) using intracameral cannulation (n=20), intravitreal cannulation (n=20), rebound tonometry (n=20) and indentation tonometry (n=20). Pressure was assessed prior vacuum, during vacuum (30 s, 1 min, 2 min, 3 min) and after releasing the vacuum (1 min and 2 min). Two groups with different predefined vacuum levels (350 mbar, 420 mbar) were investigated. Mean intracameral pressure (±SD) increased during vacuum application from 20 mm Hg to 52.00 mm Hg (±6.35mm Hg; p=0.005) and 45.18 mmHg (±4.34 mm Hg; p=0.005) for the 420 mbar and the 350 mbar vacuum levels, respectively. Mean intravitreal pressure increased from 20 mm Hg to 25.60 mm Hg (±9.85 mm Hg; p=0.058) and 28.10 mm Hg (±2.54 mm Hg; p=0.059) for the 420 mbar and the 350 mbar vacuum levels, respectively. Pressure values from indentation and rebound tonometry were in between intracameral and intravitreal values. Mean intracameral IOP was 18.1% higher (p=0.019) in the 420 mbar group compared with the 350 mbar group. During vacuum application of the liquid patient interface of the Femto LDV Z8 for femtosecond laser-assisted cataract surgery, IOP values were higher in the anterior chamber compared with the intravitreal pressure measurements. The higher predefined vacuum level (350 mbar vs 420 mbar) resulted in significant higher intracameral IOP. © Article author(s) (or their employer(s) unless otherwise stated in the text of the article) 2017. All rights reserved. No commercial use is permitted unless otherwise expressly granted.
Major, Matthew J.; Caldwell, Ryan; Fatone, Stefania
2015-01-01
Vacuum-assisted suspension (VAS) of prosthetic sockets utilizes a pump to evacuate air from between the prosthetic liner and socket, and are available as mechanical or electric systems. This technical note describes a hybrid pump that benefits from the advantages of mechanical and electric systems, and evaluates a prototype as proof-of-concept. Cyclical bench testing of the hybrid pump mechanical system was performed using a materials testing system to assess the relationship between compression cycles and vacuum pressure. Phase 1 in vivo testing of the hybrid pump was performed by an able-bodied individual using prosthesis simulator boots walking on a treadmill, and phase 2 involved an above-knee prosthesis user walking with the hybrid pump and a commercial electric pump for comparison. Bench testing of 300 compression cycles produced a maximum vacuum of 24 in-Hg. In vivo testing demonstrated that the hybrid pump continued to pull vacuum during walking, and as opposed to the commercial electric pump, did not require reactivation of the electric system during phase 2 testing. The novelty of the hybrid pump is that while the electric system provides rapid, initial vacuum suspension, the mechanical system provides continuous air evacuation while walking to maintain suspension without reactivation of the electric system, thereby allowing battery power to be reserved for monitoring vacuum levels. PMID:27462383
Sigel, Carlie S.; Guo, Huimin; Sigel, Keith M.; Zhang, Ming; Rekhtman, Natasha; Lin, Oscar; Klimstra, David S.; Jungbluth, Achim A.; Tang, Laura K.
2017-01-01
Background Histological features and Ki67 index have known utility for predicting prognosis and guiding therapy for metastatic pancreatic neuroendocrine neoplasms. Fine needle aspiration (FNA) may offer advantages for Ki67 assessment because the technique obtains highly cellular, well-preserved specimens with potential for broader tumor sampling. We evaluated concordance for grade and differentiation between concurrent core biopsy and cytology preparations. Secondly, cytological features and grade were correlated with survival. Methods Differentiation, grade by Ki67 index, and correlation of these features with survival were compared between concurrent core biopsy and cytology from 44 metastatic pancreatic neuroendocrine neoplasms. Results Differentiation by cytology smear was 38 (86%) well and 6 (14%) poor. Agreement for differentiation between smear and cell block, smear and biopsy, and cell block and biopsy was: 88%, 94%, and 83%, respectively and agreement for grade were: 68%, 54%, and 22%, respectively. Cytology differentiation and cytology grade were strong predictors of outcome with respective hazard ratio of 8.3 (95% CI: 3.1–22.1; p<0.001) and 1.9 (95% CI: 1.2–2.9) for each ascending grade. Cytology median disease specific survival projections (months) were G1= 121 (95% CI: 57–185 (estimated)); G2= 45 (95% CI 29–87); and G3=19 (95% CI 1–44) and WD=45; PD= 3; (P<.001)). Conclusions Pancreatic neuroendocrine neoplasm grading on cytology may not exactly correlate with concurrent core biopsy, but cytology differentiation and grade are predictive of survival based on stage-adjusted analysis. PMID:28094897
Soares, Jaqueline S.; Barman, Ishan; Dingari, Narahara Chari; Volynskaya, Zoya; Liu, Wendy; Klein, Nina; Plecha, Donna; Dasari, Ramachandra R.; Fitzmaurice, Maryann
2013-01-01
Microcalcifications geographically target the location of abnormalities within the breast and are of critical importance in breast cancer diagnosis. However, despite stereotactic guidance, core needle biopsy fails to retrieve microcalcifications in up to 15% of patients. Here, we introduce an approach based on diffuse reflectance spectroscopy for detection of microcalcifications that focuses on variations in optical absorption stemming from the calcified clusters and the associated cross-linking molecules. In this study, diffuse reflectance spectra are acquired ex vivo from 203 sites in fresh biopsy tissue cores from 23 patients undergoing stereotactic breast needle biopsies. By correlating the spectra with the corresponding radiographic and histologic assessment, we have developed a support vector machine-derived decision algorithm, which shows high diagnostic power (positive predictive value and negative predictive value of 97% and 88%, respectively) for diagnosis of lesions with microcalcifications. We further show that these results are robust and not due to any spurious correlations. We attribute our findings to the presence of proteins (such as elastin), and desmosine and isodesmosine cross-linkers in the microcalcifications. It is important to note that the performance of the diffuse reflectance decision algorithm is comparable to one derived from the corresponding Raman spectra, and the considerably higher intensity of the reflectance signal enables the detection of the targeted lesions in a fraction of the spectral acquisition time. Our findings create a unique landscape for spectroscopic validation of breast core needle biopsy for detection of microcalcifications that can substantially improve the likelihood of an adequate, diagnostic biopsy in the first attempt. PMID:23267090
Evans, A; Purdie, C A; Jordan, L; Macaskill, E J; Flynn, J; Vinnicombe, S
2016-11-01
The aim of this study is to establish predictors of invasion in lesions yielding an ultrasound-guided biopsy diagnosis of ductal carcinoma in situ (DCIS). Patients subjected to ultrasound-guided core biopsy yielding DCIS were studied. At shear-wave elastography (SWE) a threshold of 50 kPa was used for mean elasticity (Emean) to dichotomise the elasticity data between invasive and non-invasive masses. Data recorded included the mammographic and ultrasound features, the referral source, and grade of DCIS in the biopsy. The chi-square test was used to detect statistical significance. Of 57 lesions, 24 (42%) had invasion at excision. Symptomatic patients and patients with stiff lesions were more likely to have invasion than patients presenting through screening and with soft lesions (58% [14 of 24] versus 30% [10 of 33], p=0.03) and (51% [20 of 39] versus 22% [4 of 18], p=0.04). No other factors showed a relationship with invasion. Combining the two predictors of invasion improved risk stratification with symptomatic and stiff lesions having a risk of invasion of 67% (12 of 18) and soft lesions presenting at screening having only a 17% (2 of 12) risk of invasion (p=0.02). Stiffness on SWE and the referral source of the patient are predictors of occult invasion in women with an ultrasound-guided core biopsy diagnosis of DCIS. Copyright © 2016 The Royal College of Radiologists. Published by Elsevier Ltd. All rights reserved.
Vacuum Compatibility of Flux-Core Arc Welding (FCAW)
NASA Astrophysics Data System (ADS)
Arose, Dana; Denault, Martin; Jurcznski, Stephan
2010-11-01
Typically, vacuum chambers are welded together using gas tungsten arc welding (GTAW) or gas metal arc welding (GMAW). This is demonstrated in the vacuum chamber of Princeton Plasma Physics Lab's (PPPL) National Spherical Torus Experiment (NSTX). These processes are slow and apply excess heat to the base metal, which may cause the vacuum chamber to deform beyond designed tolerance. Flux cored arc welding (FCAW) avoids these problems, but may produce an unacceptable amount of outgasing due to the flux shielding. We believe impurities due to outgasing from FCAW will not greatly exceed those found in GTAW and GMAW welding. To test this theory, samples welded together using all three welding processes will be made and baked in a residual gas analyzer (RGA). The GTAW and GMAW welds will be tested to establish a metric for permissible outgasing. By testing samples from all three processes we hope to demonstrate that FCAW does not significantly outgas, and is therefore a viable alternative to GTAW and GMAW. Results from observations will be presented.
Li, Zhen-Feng; Shao, Xian-Hao; Zhang, Li-Qiang; Yang, Zhi-Ping; Li, Xin; Yang, Qiang; Li, Jian-Min
2016-05-01
To develop an endoscopic transnasal approach to atlas tumors and study its practicability. This article comprises two components: an illustrative case report and observational data on 50 volunteers. As to the case report, a 34 year old man presented with occipital pain for more than 3 months and underwent systematic investigation in Qilu Hospital of Shandong University. CT and MRI scans showed bony destruction in the craniovertebral junction (CVJ) suggestive of tumor. Via an endoscopic transnasal approach to the suspected atlas tumor through the inferior nasal meatus, a Gallini biopsy needle was used to obtain tissue for examination. The procedure was performed endoscopically with double orientation X-ray guidance and coaxial technology after establishing the shortest distance for the biopsy track and range of target tissue and was assisted by manual palpation. As to the observational data, 50 volunteers underwent atlas-related morphometric image measurement using gemstone CT equipment. Biopsy track angles, range for biopsy of the atlas and biopsy track distances were measured by a blinded operator on CT images. pathological examination of the biopsy resulted in diagnosis of a chordoma. There were no complications such as bleeding, infection or spinal cord injury. One month later, the patient underwent tumor resection and reconstruction in other hospital and the diagnosis of chordoma was confirmed by pathological examination of the resected specimen. Observational data: measurements obtained from CT scans of the 50 volunteers were as follows. Biopsy track angles: mean leaning inside angle 3.53° ± 0.39° and mean posterior slope angle 13.05° ± 1.39°. Range for atlas biopsy: transverse diameter 11.84 ± 1.24 mm and longitudinal diameter 9.67 ± 0.90 mm. Biopsy track distances: from atlas to nostril, and to anterior and posterior edges of the inferior turbinate mucosa were 94.52 ± 5.03 mm, 78.21 ± 4.63 mm, and 33.51 ± 3.13 mm, respectively. An endoscopic transnasal approach enables biopsy and diagnosis of tumors in the anterior arch of the atlas. Relevant measurements were obtained by assessing CT scans of 50 volunteers to assist operators to determine the effective and safe range for transnasal atlas biopsy. © 2016 Chinese Orthopaedic Association and John Wiley & Sons Australia, Ltd.
Small renal mass biopsy--how, what and when: report from an international consensus panel.
Tsivian, Matvey; Rampersaud, Edward N; del Pilar Laguna Pes, Maria; Joniau, Steven; Leveillee, Raymond J; Shingleton, William B; Aron, Monish; Kim, Charles Y; DeMarzo, Angelo M; Desai, Mihir M; Meler, James D; Donovan, James F; Klingler, Hans Christoph; Sopko, David R; Madden, John F; Marberger, Michael; Ferrandino, Michael N; Polascik, Thomas J
2014-06-01
To discuss the use of renal mass biopsy (RMB) for small renal masses (SRMs), formulate technical aspects, outline potential pitfalls and provide recommendations for the practicing clinician. The meeting was conducted as an informal consensus process and no scoring system was used to measure the levels of agreement on the different topics. A moderated general discussion was used as the basis for consensus and arising issues were resolved at this point. A consensus was established and lack of agreement to topics or specific items was noted at this point. Recommended biopsy technique: at least two cores, sampling different tumour regions with ultrasonography being the preferred method of image guidance. Pathological interpretation: 'non-diagnostic samples' should refer to insufficient material, inconclusive and normal renal parenchyma. For non-diagnostic samples, a repeat biopsy is recommended. Fine-needle aspiration may provide additional information but cannot substitute for core biopsy. Indications for RMB: biopsy is recommended in most cases except in patients with imaging or clinical characteristics indicative of pathology (syndromes, imaging characteristics) and cases whereby conservative management is not contemplated. RMB is recommended for active surveillance but not for watchful-waiting candidates. We report the results of an international consensus meeting on the use of RMB for SRMs, defining the technique, pathological interpretation and indications. © 2013 The Authors. BJU International © 2013 BJU International.
Blumenfeld, Philip; Hata, Nobuhiko; DiMaio, Simon; Zou, Kelly; Haker, Steven; Fichtinger, Gabor; Tempany, Clare M C
2007-09-01
To quantify needle placement accuracy of magnetic resonance image (MRI)-guided core needle biopsy of the prostate. A total of 10 biopsies were performed with 18-gauge (G) core biopsy needle via a percutaneous transperineal approach. Needle placement error was assessed by comparing the coordinates of preplanned targets with the needle tip measured from the intraprocedural coherent gradient echo images. The source of these errors was subsequently investigated by measuring displacement caused by needle deflection and needle susceptibility artifact shift in controlled phantom studies. Needle placement error due to misalignment of the needle template guide was also evaluated. The mean and standard deviation (SD) of errors in targeted biopsies was 6.5 +/- 3.5 mm. Phantom experiments showed significant placement error due to needle deflection with a needle with an asymmetrically beveled tip (3.2-8.7 mm depending on tissue type) but significantly smaller error with a symmetrical bevel (0.6-1.1 mm). Needle susceptibility artifacts observed a shift of 1.6 +/- 0.4 mm from the true needle axis. Misalignment of the needle template guide contributed an error of 1.5 +/- 0.3 mm. Needle placement error was clinically significant in MRI-guided biopsy for diagnosis of prostate cancer. Needle placement error due to needle deflection was the most significant cause of error, especially for needles with an asymmetrical bevel. (c) 2007 Wiley-Liss, Inc.
Protection of polyphenols in blueberry juice by vacuum-assisted block freeze concentration.
Orellana-Palma, Patricio; Petzold, Guillermo; Pierre, Lissage; Pensaben, José Manuel
2017-11-01
Block freeze concentration allows produces high-quality cryoconcentrates with important protection of valuable components from fresh fruit juices. The aim of this study was to investigate the use of vacuum-assisted block freeze concentration under different experimental conditions to protect polyphenols in the elaboration of concentrated blueberry juice. Fresh blueberry juice was radial or unidirectional frozen at -20 and -80 °C for 12 h and vacuum process was performed at 80 kPa during 120 min. Results showed a significant solute increased in the concentrated fraction in all treatments, and the best treatment was - 20 °C/unidirectional with a value of ≈63 °Brix, equivalent to an increase of 3.8 times in the total polyphenol content (76% of retention). The color of concentrated samples was darker than the initial sample, with ΔE* values of >25 CIELab units in all treatments. The vacuum-assisted block freeze concentrations was an effective technology for protecting polyphenols and obtain a concentrated with a higher concentration of solids from blueberry juice, as well as interesting values of process parameters. Copyright © 2017 Elsevier Ltd. All rights reserved.
Choe, Regine; Konecky, Soren D.; Corlu, Alper; Lee, Kijoon; Durduran, Turgut; Busch, David R.; Pathak, Saurav; Czerniecki, Brian J.; Tchou, Julia; Fraker, Douglas L.; DeMichele, Angela; Chance, Britton; Arridge, Simon R.; Schweiger, Martin; Culver, Joseph P.; Schnall, Mitchell D.; Putt, Mary E.; Rosen, Mark A.; Yodh, Arjun G.
2009-01-01
We have developed a novel parallel-plate diffuse optical tomography (DOT) system for three-dimensional in vivo imaging of human breast tumor based on large optical data sets. Images of oxy-, deoxy-, total-hemoglobin concentration, blood oxygen saturation, and tissue scattering were reconstructed. Tumor margins were derived using the optical data with guidance from radiology reports and Magnetic Resonance Imaging. Tumor-to-normal ratios of these endogenous physiological parameters and an optical index were computed for 51 biopsy-proven lesions from 47 subjects. Malignant cancers (N=41) showed statistically significant higher total hemoglobin, oxy-hemoglobin concentration, and scattering compared to normal tissue. Furthermore, malignant lesions exhibited a two-fold average increase in optical index. The influence of core biopsy on DOT results was also explored; the difference between the malignant group measured before core biopsy and the group measured more than one week after core biopsy was not significant. Benign tumors (N=10) did not exhibit statistical significance in the tumor-to-normal ratios of any parameter. Optical index and tumor-to-normal ratios of total hemoglobin, oxy-hemoglobin concentration, and scattering exhibited high area under the receiver operating characteristic curve values from 0.90 to 0.99, suggesting good discriminatory power. The data demonstrate that benign and malignant lesions can be distinguished by quantitative three-dimensional DOT. PMID:19405750
Na, Dong Gyu; Jung, So Lyung; Kim, Ji-hoon; Sung, Jin Yong; Kim, Kyu Sun; Lee, Jeong Hyun; Shin, Jung Hee; Choi, Yoon Jung; Ha, Eun Ju; Lim, Hyun Kyung; Kim, Soo Jin; Hahn, Soo Yeon; Lee, Kwang Hwi; Choi, Young Jun; Youn, Inyoung; Kim, Young Joong; Ahn, Hye Shin; Ryu, Ji Hwa; Baek, Seon Mi; Sim, Jung Suk; Jung, Chan Kwon; Lee, Joon Hyung
2017-01-01
Core needle biopsy (CNB) has been suggested as a complementary diagnostic method to fine-needle aspiration in patients with thyroid nodules. Many recent CNB studies have suggested a more advanced role for CNB, but there are still no guidelines on its use. Therefore, the Task Force Committee of the Korean Society of Thyroid Radiology has developed the present consensus statement and recommendations for the role of CNB in the diagnosis of thyroid nodules. These recommendations are based on evidence from the current literature and expert consensus. PMID:28096731
Coca, H A; Cebula, H; Benmekhbi, M; Chenard, M P; Entz-Werle, N; Proust, F
2016-12-01
Diffuse intrinsic pontine gliomas (DIPG) constitute 10-15% of all brain tumors in the pediatric population; currently prognosis remains poor, with an overall survival of 7-14 months. Recently the indication of DIPG biopsy has been enlarged due to the development of molecular biology and various ongoing clinical and therapeutic trials. Classically a biopsy is performed using a stereotactic frame assisted procedure but the workflow may sometimes be heavy and more complex especially in children. In this study the authors present their experience with frameless robotic-guided biopsy of DIPG in a pediatric population. Retrospective study on a series of five consecutive pediatric patients harboring DIPG treated over a 4-year period. All patients underwent frameless robotic-guided biopsy via a transcerebellar approach. Among the 5 patients studied 3 were male and 2 female with a median age of 8.6 years [range 5 to 13 years]. Clinical presentation included ataxia, hemiparesis and cranial nerve palsy in all patients. MRI imaging of the lesion showed typical DIPG features (3 of them located in the pons) with hypo-intensity on T1 and hyper-intensity signal on T2 sequences and diffuse gadolinium enhancement. The mean procedure time was 56minutes (range 45 to 67minutes). No new postoperative neurological deficits were recorded. Histological diagnosis was achieved in all cases as follows: two anaplastic astrocytomas (grade III), two glioblastomas, and one diffuse astrocytoma (grade III). Frameless robotic assisted biopsy of DIPG in pediatric population is an easier, effective, safe and highly accurate method to achieve diagnosis. Copyright © 2016 Elsevier Masson SAS. All rights reserved.
Al-Subhi, FS; Zuker, RM; Cole, WG
2010-01-01
Necrotizing fasciitis is a severe soft tissue infection that can involve skin, subcutaneous fat, fascia and muscle. It can result in devastating sequelae including tissue necrosis, sepsis, toxic shock syndrome, cardiopulmonary collapse and death. To control rapidly spreading necrosis, early diagnosis and aggressive surgical treatment with extensive radical debridement of the affected areas is necessary, as well as systemic administration of broad-spectrum antimicrobials and, very often, intensive care support. The subatmospheric negative pressure dressing has been previously used in acute and complex wounds management. The concept of using vacuum-assisted closure dressing as another management component is presented in the current article. PMID:22131841
Deliktas, Hasan; Sahin, Hayrettin; Cetinkaya, Mehmet; Dere, Yelda; Erdogan, Omer; Baldemir, Ercan
2016-08-01
The aim of this study was to determine the minimal core length to be taken per cc of prostate volume for an effective prostate biopsy. A retrospective analysis was performed on the records of 379 patients who underwent a first prostate biopsy with 12 to 16 cores under transrectal ultrasound guidance between September 2012 and April 2015. For each patient, the core length per cc of the prostate and the percentage of sampled prostate volume were calculated, and these values were compared between the patients with and without prostate cancer. A total of 348 patients were included in the study. Cancer was determined in 26.4% of patients. The mean core length taken per cc of prostate and the percentage of sampled prostate volume were determined to be 3.40 ± 0.15 mm/cc (0.26%; range, 0.08-0.63 cc) in patients with cancer and 2.75 ± 0.08 mm/cc (0.20%; range, 0.04-0.66 cc) in patients without cancer (P = .000 and P = .000), respectively. Core length taken per cc of prostate of > 3.31 mm/cc was found to be related to an increase in the rates of prostate cancer diagnosis (odds ratio, 2.84; 95% confidence interval, 1.68-4.78). The rate of cancer determination for core length taken per cc of prostate of < 3.31 mm/cc was 19.9% and of > 3.31 mm/cc, 41.1%. Core length taken per cc of prostate and the percentage of sampled prostate volume are important morphometric parameters in the determination of prostate cancer. The results of study suggest a core length per cc of the prostate of > 3.31 mm/cc as a cutoff value for quality assurance. Copyright © 2016 Elsevier Inc. All rights reserved.
Acosta, Stefan; Björck, Martin; Petersson, Ulf
2017-01-01
The aim of this paper was to review the literature on vacuum-assisted wound closure and mesh-mediated fascial traction (VAWCM) in open abdomen therapy. It was designed as systematic review of observational studies. A Pub Med, EMBASE and Cochrane search from 2007/01-2016/07 was performed combining the Medical Subject Headings "vacuum", "mesh-mediated fascial traction", "temporary abdominal closure", "delayed abdominal closure", "open abdomen", "abdominal compartment syndrome", "negative pressure wound therapy" or "vacuum assisted wound closure". Eleven original studies were found including patients numbering from 7 to 111. Six studies were prospective and five were retrospective. Nine studies were on mixed surgical (n = 9), vascular (n = 6) and trauma (n = 6) patients, while two were exclusively on vascular patients. The primary fascial closure rate per protocol varied from 80-100%. The time to closure of the open abdomen varied between 9-32 days. The entero-atmospheric fistula rate varied from 0-10.0%. The in-hospital survival rate varied from 57-100%. In the largest prospective study, the incisional hernia rate among survivors at 63 months of median follow-up was 54% (27/50), and 16 (33%) repairs out of 48 incisional hernias were performed throughout the study period. The study patients reported lower short form health survey (SF-36) scores than the mean reference population, mainly dependent on the prevalence of major co-morbidities. There was no difference in SF-36 scores or a modified ventral hernia pain questionnaire (VHPQ) at 5 years of follow up between those with versus those without incisional hernias. A high primary fascial closure rate can be achieved with the vacuum-assisted wound closure and meshmediated fascial traction technique in elderly, mainly non-trauma patients, in need of prolonged open abdomen therapy.
Wang, Mei; Kimbrell, Hillary Z.; Sholl, Andrew B.; Tulman, David B.; Elfer, Katherine N.; Schlichenmeyer, Tyler C.; Lee, Benjamin R.; Lacey, Michelle; Brown, J. Quincy
2015-01-01
Rapid assessment of prostate core biopsy pathology at the point-of-procedure could provide benefit in a variety of clinical situations. Even with advanced trans-rectal ultrasound guidance and saturation biopsy protocols, prostate cancer can be missed in up to half of all initial biopsy procedures. In addition, collection of tumor specimens for downstream histological, molecular, and genetic analysis is hindered by low tumor yield due to inability to identify prostate cancer grossly. However, current point-of-procedure pathology protocols such as frozen section analysis (FSA) are destructive, and too time- and labor-intensive to be practical or economical. Ex vivo microscopy of the excised specimens, stained with fast-acting fluorescent histology dyes, could be an attractive non-destructive alternative to FSA. In this work, we report the first demonstration of video-rate structured illumination microscopy (VR-SIM) for rapid high-resolution diagnostic imaging of prostate biopsies in realistic point-of-procedure timeframes. Large mosaic images of prostate biopsies stained with acridine orange are rendered in seconds, and contain excellent contrast and detail, exhibiting close correlation with corresponding H&E histology. A clinically-relevant review of VR-SIM images of 34 unfixed and uncut prostate core biopsies by two independent pathologists resulted in an area under the ROC curve (AUC) of 0.82–0.88, with a sensitivity ranging from 63–88% and a specificity ranging from 78–89%. When biopsies contained more than 5% tumor content, the sensitivity improved to 75–92%. The image quality, speed, minimal complexity, and ease of use of VR-SIM could prove to be features in favor of adoption as an alternative to destructive pathology at the point-of-procedure. PMID:26282168
CT fluoroscopy-guided robotically-assisted lung biopsy
NASA Astrophysics Data System (ADS)
Xu, Sheng; Fichtinger, Gabor; Taylor, Russell H.; Banovac, Filip; Cleary, Kevin
2006-03-01
Lung biopsy is a common interventional radiology procedure. One of the difficulties in performing the lung biopsy is that lesions move with respiration. This paper presents a new robotically assisted lung biopsy system for CT fluoroscopy that can automatically compensate for the respiratory motion during the intervention. The system consists of a needle placement robot to hold the needle on the CT scan plane, a radiolucent Z-frame for registration of the CT and robot coordinate systems, and a frame grabber to obtain the CT fluoroscopy image in real-time. The CT fluoroscopy images are used to noninvasively track the motion of a pulmonary lesion in real-time. The position of the lesion in the images is automatically determined by the image processing software and the motion of the robot is controlled to compensate for the lesion motion. The system was validated under CT fluoroscopy using a respiratory motion simulator. A swine study was also done to show the feasibility of the technique in a respiring animal.
Kim, Hark Kyun; Reyzer, Michelle L.; Choi, Il Ju; Kim, Chan Gyoo; Kim, Hee Sung; Oshima, Akira; Chertov, Oleg; Colantonio, Simona; Fisher, Robert J.; Allen, Jamie L.; Caprioli, Richard M.; Green, Jeffrey E.
2012-01-01
To date, proteomic analyses on gastrointestinal cancer tissue samples have been performed using surgical specimens only, which are obtained after a diagnosis is made. To determine if a proteomic signature obtained from endoscopic biopsy samples could be found to assist with diagnosis, frozen endoscopic biopsy samples collected from 63 gastric cancer patients and 43 healthy volunteers were analyzed using matrix-assisted laser desorption/ionization (MALDI) mass spectrometry. A statistical classification model was developed to distinguish tumor from normal tissues using half the samples and validated with the other half. A protein profile was discovered consisting of 73 signals that could classify 32 cancer and 22 normal samples in the validation set with high predictive values (positive and negative predictive values for cancer, 96.8% and 91.3%; sensitivity, 93.8%; specificity, 95.5%). Signals overexpressed in tumors were identified as α-defensin-1, α-defensin-2, calgranulin A, and calgranulin B. A protein profile was also found to distinguish pathologic stage Ia (pT1N0M0) samples (n = 10) from more advanced stage (Ib or higher) tumors (n = 48). Thus, protein profiles obtained from endoscopic biopsy samples may be useful in assisting with the diagnosis of gastric cancer and, possibly, in identifying early stage disease. PMID:20557134
Asano, Fumihiro; Ishida, Takashi; Shinagawa, Naofumi; Sukoh, Noriaki; Anzai, Masaki; Kanazawa, Kenya; Tsuzuku, Akifumi; Morita, Satoshi
2017-12-11
Transbronchial biopsy for peripheral pulmonary lesions is generally performed under X-ray fluoroscopy. Virtual bronchoscopic navigation (VBN) is a method in which virtual images of the bronchial route to the lesion are produced based on CT images obtained before VBN, and the bronchoscope is guided using these virtual images, improving the diagnostic yield of peripheral pulmonary lesions. VBN has the possibility of eliminating the need for X-ray fluoroscopy in the bronchoscopic diagnosis of peripheral lesions. To determine whether VBN can be a substitute for X-ray fluoroscopy, a randomized multicenter trial (non-inferiority trial) was performed in VBN and X-ray fluoroscopy (XRF) -assisted groups. The non-inferiority margin in the VBN-assisted group compared with the XRF-assisted group was set at 15%. The subjects consisted of 140 patients with peripheral pulmonary lesions with a mean diameter > 3 cm. In the VBN-assisted group, the bronchoscope was guided to the lesion using a VBN system without X-ray fluoroscopy. In the XRF-assisted group, the same bronchoscope was guided to the lesion under X-ray fluoroscopy. Subsequently, in both groups, the lesion was visualized using endobronchial ultrasonography with a guide sheath (EBUS/GS), and biopsy was performed. In this serial procedure, X-ray fluoroscopy was not used in the VBNA group. The subjects of analysis consisted of 129 patients. The diagnostic yield was 76.9% (50/65) in the VBN-assisted group and 85.9% (55/64) in the XRF-assisted group. The difference in the diagnostic yield between the two groups was -9.0% (95% confidence interval: -22.3% ~ 4.3%). The non-inferiority of the VBN-assisted group could not be confirmed. The rate of visualizing lesions by EBUS was 95.4% (62/65) in the VBN-assisted group and 96.9% (62/64) in the XRF-assisted group, being high in both groups. On EBUS/GS, a bronchoscope and biopsy instruments may be guided to the lesions using VBN without X-ray fluoroscopy, but X-ray fluoroscopy is necessary to improve the accuracy of sample collection from lesions. During transbronchial biopsy for peripheral pulmonary lesions, VBN cannot be a substitute for X-ray fluoroscopy. UMIN-CTR (UMIN000001710); registered 16 February 2009.
Pal, Raj P; Ahmad, Ros; Trecartan, Shaun; Voss, James; Ahmed, Shaista; Bazo, Alvaro; Lloyd, Jon; Walton, Thomas J
2018-03-01
In this study we evaluated the diagnostic performance of transrectal ultrasound guided biopsy and multiparametric magnetic resonance imaging to detect prostate cancer against transperineal prostate mapping biopsy as the reference test. Transrectal ultrasound guided biopsy, multiparametric magnetic resonance imaging and transperineal prostate mapping biopsy were performed in 426 patients between April 2012 and January 2016. Patients initially underwent systematic 12 core transrectal ultrasound guided biopsy followed 3 months later by 1.5 Tesla, high resolution T2, diffusion-weighted, dynamic contrast enhanced multiparametric magnetic resonance imaging. Two specialist uroradiologists blinded to the results of transperineal prostate mapping biopsy allocated a PI-RADS™ (Prostate Imaging-Reporting and Data System) score to each multiparametric magnetic resonance imaging study. Transperineal prostate mapping biopsy with 5 mm interval sampling, which was performed within 6 months of multiparametric magnetic resonance imaging, served as the reference test. Transrectal ultrasound guided biopsy identified 247 of 426 patients with prostate cancer and 179 of 426 with benign histology. Transperineal prostate mapping biopsy detected prostate cancer in 321 of 426 patients. On transperineal prostate mapping biopsy 94 of 179 patients with benign transrectal ultrasound guided biopsy had prostate cancer and 95 of 247 with prostate cancer on transrectal ultrasound guided biopsy were identified with cancer of higher grade. Using a multiparametric magnetic resonance imaging PI-RADS score of 3 or greater to detect significant prostate cancer, defined as any core containing Gleason 4 + 3 or greater prostate cancer on transperineal prostate mapping biopsy, the ROC AUC was 0.754 (95% CI 0.677-0.819) with 87.0% sensitivity (95% CI 77.3-97.0), 55.3% specificity (95% CI 50.2-60.4) and 97.1% negative predictive value (95% CI 94.8-99.4). Multiparametric magnetic resonance imaging is a more accurate diagnostic test than transrectal ultrasound guided biopsy. However, a significant proportion of ISUP (International Society of Urological Pathology) Grade Group 2 prostate cancer remained undetected following multiparametric magnetic resonance imaging. Although multiparametric magnetic resonance imaging could avoid unnecessary biopsy in many patients with ISUP Grade Group 3 or greater prostate cancer, at less stringent definitions of significant cancer a substantial proportion of prostate cancer would remain undetected after multiparametric magnetic resonance imaging. Copyright © 2018 American Urological Association Education and Research, Inc. Published by Elsevier Inc. All rights reserved.
Method of making hermetic seals for hermetic terminal assemblies
Hsu, John S.; Marlino, Laura D.; Ayers, Curtis W.
2010-04-13
This invention teaches methods of making a hermetic terminal assembly comprising the steps of: inserting temporary stops, shims and jigs on the bottom face of a terminal assembly thereby blocking assembly core open passageways; mounting the terminal assembly inside a vacuum chamber using a temporary assembly perimeter seal and flange or threaded assembly interfaces; mixing a seal admixture and hardener in a mixer conveyor to form a polymer seal material; conveying the polymer seal material into a polymer reservoir; feeding the polymer seal material from the reservoir through a polymer outlet valve and at least one polymer outlet tube into the terminal assembly core thereby filling interstitial spaces in the core adjacent to service conduits, temporary stop, and the terminal assembly casing; drying the polymer seal material at room temperature thereby hermetically sealing the core of the terminal assembly; removing the terminal assembly from the vacuum chamber, and; removing the temporary stops, shims.
Percutaneous Biopsy of Retrobulbar Masses: Anatomical Considerations and MRI Guidance
DOE Office of Scientific and Technical Information (OSTI.GOV)
Edalat, Faramarz, E-mail: faramarz.edalat@gmail.com; Cazzato, Roberto Luigi; Garnon, Julien
2017-04-15
PurposeObtaining adequate tissue from retrobulbar masses remains a challenge. To this end, a new method of retrobulbar mass biopsy using MRI guidance is presented.Materials and MethodsTwo patients (7- and 71-year-old male) with indeterminate retrobulbar masses underwent bioptic and cytological samplings using MR-compatible 18G and 20–22G needles, and multi-planar MR fluoroscopy. An inferior approach was taken to avoid injury to the optic nerve and ophthalmic arteries.ResultsThe two biopsies were completed without complication. The core biopsy resulted in a final diagnosis, whereas the cytological sampling was non-diagnostic.ConclusionPercutaneous MR-guided retrobulbar mass biopsy proved to be feasible and safe in the two cases describedmore » in this report.« less
Hill, S. L.; Holt, D. W.
2007-01-01
Abstract: There has been much advancement in perfusion technology over its 50 years of progression. One of these techniques is vacuum-assisted venous drainage (VAVD). Many perfusionists augment venous drainage using VAVD, typically from a wall vacuum source. This study explores alternates to providing VAVD if the wall vacuum fails. In two porcine laboratories, ∼36 in. of 3/16-in. tubing was connected to a sucker return port and placed into the roller head next to the arterial pump. The vacuum was monitored with a DLP pressure monitoring system (Medtronic). This system was connected to small-bore tubing and attached to a stopcock on top of the reservoir. The vacuum was regulated using another stopcock connected to a non-filtered luer lock port on top of the reservoir or by a segment of 3 × 0.25-in.-diameter tubing attached to the vent port with a c-clamp. Vacuum drainage was achieved, ranging from −18 mmHg to −71 mmHg by manipulating the stopcock or c-clamp. Changes in venous drainage were seen by volume fluctuations in the venous reservoir. The vacuum was adjusted to account for dramatic changes. Augmented venous drainage using a roller pump can be achieved successfully during cardiopulmonary bypass (CPB). This method of active drainage can be used in lieu of wall suction or during times of emergency if wall suction fails. PMID:18293812
[Assessment of vacuum-assisted vaginal delivery in a frank breech presentation].
Bleu, G; Deruelle, P; Demetz, J; Michel, S; Dufour, P; Depret, S; Subtil, D
2015-02-01
After verification of the eligibility criteria and with an obstetrician familiar with the specific maneuvers likely to be needed, vaginal delivery of breech presentations is possible. If problems arise during the active pushing phase of labor, vacuum extraction has been described in the literature for this uncommon condition with limited series. The aim of this study is to assess retrospectively vacuum extraction in frank breech presentation in our center. This retrospective study of trials of vaginal delivery of fetuses in breech presentation at term compares cases according to whether they did or did not use a vacuum extraction. During a two-year period, 83 patients, whom had trials of vaginal delivery in breech presentations, reached the active pushing/bearing down stage after complete cervical dilatation. Vacuum assistance was applied in six of these (7.2 %). The failure rate for vaginal delivery was significantly higher in the group with compared to without vacuum extraction (33.3 % versus 6.5 %, P<0.05). Moreover, the mean pH at birth was significantly lower in the group with vacuum extraction (7.12±0.11 versus 7.20±0.08, P<0.05), and these infants more frequently had deep cutaneous injuries (66.7 % versus 26.0 %, P<0.05). In fetuses in breech presentation, when vaginal delivery failed, it seems to be safer for the fetuses to perform caesarean section rather than attempt vacuum extraction. Copyright © 2015 Elsevier Masson SAS. All rights reserved.
Stone, Nelson N; Mouraviev, Vladimir; Schechter, David; Lucia, M Scott; Smith, Elizabeth E; Arangua, Paul; Hoenemeyer, John; Rosa, Jim; Bawa, Rajan; Crawford, E David
2017-09-01
To increase the likelihood of detecting anterior cancers within the prostate and provide a specimen that spans the length of the gland. Newly designed 17- and 15-gauge (G) biopsy needles, a variable actuator, and an integrated pathology system intended for the longer cores were developed and tested for this purpose. Testing was performed comparing 2 common cannula tip grinds, a Vet-point (sharp tip) and a Menghini-point (atraumatic tip), and were tested against 18-G Bard Monopty in porcine kidney. A variable actuator was developed to fire the needle 20-60 mm and tested in cadaver prostates. The aggregate firings for 3 different shot lengths comparing the Vet- with the Menghini-tip cannulas demonstrated 91% vs 85.2% fill (length of specimen/length of core bed, P = .007). A 15-G trocar needle with the Vet-tip cannula also had the best performance, with an aggregate standard deviation of 6.4% across 3 firing ranges and a minimum to maximum specimen length of 81%-105% of potential fill. Cadaver testing with the Vet-tip needles in the actuator for the transrectal (17-G) and transperineal (15-G) biopsies demonstrated mean fills of 93.3% and 76.5%, respectively. The new transrectal ultrasound needle obtained a 2-fold increase in specimen length over the standard Bard device (P <.001). Longer and consistent cores were obtained using the new biopsy needles. Combined with an adjustable actuator, the physician can obtain specimens that include peripheral and anterior zone tissue in 1 core. Determination of cancer location on the longer specimens could enhance focal therapy planning. Copyright © 2017 Elsevier Inc. All rights reserved.
Schmid-Bindert, Gerald; Wang, Yongsheng; Jiang, Hongbin; Sun, Hui; Henzler, Thomas; Wang, Hao; Pilz, Lothar R.; Ren, Shengxiang; Zhou, Caicun
2013-01-01
Background Multiple biomarker testing is necessary to facilitate individualized treatment of lung cancer patients. More than 80% of lung cancers are diagnosed based on very small tumor samples. Often there is not enough tissue for molecular analysis. We compared three minimal invasive sampling methods with respect to RNA quantity for molecular testing. Methods 106 small biopsies were prospectively collected by three different methods forceps biopsy, endobronchial ultrasound (EBUS) guided transbronchial needle aspiration (TBNA), and CT-guided core biopsy. Samples were split into two halves. One part was formalin fixed and paraffin embedded for standard pathological evaluation. The other part was put in RNAlater for immediate RNA/DNA extraction. If the pathologist confirmed the diagnosis of non-small cell lung cancer(NSCLC), the following molecular markers were tested: EGFR mutation, ERCC1, RRM1 and BRCA1. Results Overall, RNA-extraction was possible in 101 out of 106 patients (95.3%). We found 49% adenocarcinomas, 38% squamouscarcinomas, and 14% non-otherwise-specified(NOS). The highest RNA yield came from endobronchial ultrasound guided needle aspiration, which was significantly higher than bronchoscopy (37.74±41.09 vs. 13.74±15.53 ng respectively, P = 0.005) and numerically higher than CT-core biopsy (37.74±41.09 vs. 28.72±44.27 ng respectively, P = 0.244). EGFR mutation testing was feasible in 100% of evaluable patients and its incidence was 40.8%, 7.9% and 14.3% in adenocarcinomas, squamouscarcinomas and NSCLC NOS subgroup respectively. There was no difference in the feasibility of molecular testing between the three sampling methods with feasibility rates for ERCC1, RRM1 and BRCA1 of 91%, 87% and 81% respectively. Conclusion All three methods can provide sufficient tumor material for multiple biomarkers testing from routinely obtained small biopsies in lung cancer patients. In our study EBUS guided needle aspiration provided the highest amount of tumor RNA compared to bronchoscopy or CT guided core biopsy. Thus EBUS should be considered as an acceptable option for tissue acquisition for molecular testing. PMID:24205040
Doval, D C; Deshpande, R; Dhabhar, B; Babu, K G; Prabhash, K; Chopra, R; Sripada, P V; Deshmukh, C; Suryavanshi, M
2017-12-01
More than 50% of non-small cell lung cancer (NSCLC) cases harbor an actionable mutation, and molecular testing at different intervals can help in personalized and targeted treatment. Core tissue biopsy and needle biopsy done at the time of diagnosis/disease progression are interventional, time-consuming and can affect the patients adversely. Noninterventional biomarker testing by liquid biopsy promises to revolutionize advanced stage cancer screening. The present report was formulated based on an expert panel meeting of renowned oncologists who gave their opinions for minimally invasive liquid biopsy to detect targetable molecular biomarkers in advanced NSCLC cases. An exhaustive literature search was done to support their recommendations. Clinical utility of minimally invasive liquid biopsy, for detection of molecular biomarkers in advanced stage NSCLC patients, was broadly discussed by the key opinion leaders.
de Lima, Luciano S.; Martineau, Eric; De Marchi, Francilaine E.; Palin, Marie-France; dos Santos, Geraldo T.; Petit, Hélène V.
2016-01-01
The objective of this study was to develop a technique for carrying out repeated biopsies of the mammary gland of lactating dairy cows that provides enough material to monitor enzyme activities and gene expression in mammary secretory tissue. A total of 16 Holstein cows were subjected to 4 mammary biopsies each at 3-week intervals for a total of 64 biopsies. A 0.75-cm incision was made through the skin and subcutaneous tissue of the mammary gland and a trocar and cannula were inserted using a circular motion. The trocar was withdrawn and a syringe was plugged into the base of the cannula to create a vacuum for sampling mammary tissue. To reduce bleeding, hand pressure was put on the surgery site after biopsy and skin closure and ice was applied for at least 2 h after the biopsy using a cow bra. The entire procedure took an average of 25 min. Two attempts were usually enough to obtain 800 mg of tissue. Visual examination of milk samples 10 d after the biopsy indicated no trace of blood, except in samples from 2 cows. All wounds healed without infection and subcutaneous hematomas resorbed within 7 d. There was no incidence of mastitis throughout the lactation. This technique provides a new tool for biopsy of the mammary gland repeated at short intervals with the main effect being a decrease in milk production. Although secondary complications leading to illness or death are always a risk with any procedure, this biopsy technique was carried out without complications to the health of animals and with no incidence of mastitis during the lactation. PMID:27408336
de Lima, Luciano S; Martineau, Eric; De Marchi, Francilaine E; Palin, Marie-France; Dos Santos, Geraldo T; Petit, Hélène V
2016-07-01
The objective of this study was to develop a technique for carrying out repeated biopsies of the mammary gland of lactating dairy cows that provides enough material to monitor enzyme activities and gene expression in mammary secretory tissue. A total of 16 Holstein cows were subjected to 4 mammary biopsies each at 3-week intervals for a total of 64 biopsies. A 0.75-cm incision was made through the skin and subcutaneous tissue of the mammary gland and a trocar and cannula were inserted using a circular motion. The trocar was withdrawn and a syringe was plugged into the base of the cannula to create a vacuum for sampling mammary tissue. To reduce bleeding, hand pressure was put on the surgery site after biopsy and skin closure and ice was applied for at least 2 h after the biopsy using a cow bra. The entire procedure took an average of 25 min. Two attempts were usually enough to obtain 800 mg of tissue. Visual examination of milk samples 10 d after the biopsy indicated no trace of blood, except in samples from 2 cows. All wounds healed without infection and subcutaneous hematomas resorbed within 7 d. There was no incidence of mastitis throughout the lactation. This technique provides a new tool for biopsy of the mammary gland repeated at short intervals with the main effect being a decrease in milk production. Although secondary complications leading to illness or death are always a risk with any procedure, this biopsy technique was carried out without complications to the health of animals and with no incidence of mastitis during the lactation.
Circulating tumor DNA: a promising biomarker in the liquid biopsy of cancer.
Cheng, Feifei; Su, Li; Qian, Cheng
2016-07-26
Tissue biopsy is the standard diagnostic procedure for cancers and also provides a material for genotyping, which can assist in the targeted therapies of cancers. However, tissue biopsy-based cancer diagnostic procedures have limitations in their assessment of cancer development, prognosis and genotyping, due to tumor heterogeneity and evolution. Circulating tumor DNA (ctDNA) is single- or double-stranded DNA released by the tumor cells into the blood and it thus harbors the mutations of the original tumor. In recent years, liquid biopsy based on ctDNA analysis has shed a new light on the molecular diagnosis and monitoring of cancer. Studies found that the screening of genetic mutations using ctDNA is highly sensitive and specific, suggesting that ctDNA analysis may significantly improve current systems of tumor diagnosis, even facilitating early-stage detection. Moreover, ctDNA analysis is capable of accurately determining the tumor progression, prognosis and assisting in targeted therapy. Therefore, using ctDNA as a liquid biopsy may herald a revolution for tumor management. Herein, we review the biology of ctDNA, its detection methods and potential applications in tumor diagnosis, treatment and prognosis.
Circulating tumor DNA: a promising biomarker in the liquid biopsy of cancer
Cheng, Feifei; Su, Li; Qian, Cheng
2016-01-01
Tissue biopsy is the standard diagnostic procedure for cancers and also provides a material for genotyping, which can assist in the targeted therapies of cancers. However, tissue biopsy-based cancer diagnostic procedures have limitations in their assessment of cancer development, prognosis and genotyping, due to tumor heterogeneity and evolution. Circulating tumor DNA (ctDNA) is single- or double-stranded DNA released by the tumor cells into the blood and it thus harbors the mutations of the original tumor. In recent years, liquid biopsy based on ctDNA analysis has shed a new light on the molecular diagnosis and monitoring of cancer. Studies found that the screening of genetic mutations using ctDNA is highly sensitive and specific, suggesting that ctDNA analysis may significantly improve current systems of tumor diagnosis, even facilitating early-stage detection. Moreover, ctDNA analysis is capable of accurately determining the tumor progression, prognosis and assisting in targeted therapy. Therefore, using ctDNA as a liquid biopsy may herald a revolution for tumor management. Herein, we review the biology of ctDNA, its detection methods and potential applications in tumor diagnosis, treatment and prognosis. PMID:27223063
Wang, Ya-Qi; Wu, Zhen-Feng; Ke, Gang; Yang, Ming
2014-12-31
An effective vacuum assisted extraction (VAE) technique was proposed for the first time and applied to extract bioactive components from Andrographis paniculata. The process was carefully optimized by response surface methodology (RSM). Under the optimized experimental conditions, the best results were obtained using a boiling temperature of 65 °C, 50% ethanol concentration, 16 min of extraction time, one extraction cycles and a 12:1 liquid-solid ratio. Compared with conventional ultrasonic assisted extraction and heat reflux extraction, the VAE technique gave shorter extraction times and remarkable higher extraction efficiency, which indicated that a certain degree of vacuum gave the solvent a better penetration of the solvent into the pores and between the matrix particles, and enhanced the process of mass transfer. The present results demonstrated that VAE is an efficient, simple and fast method for extracting bioactive components from A. paniculata, which shows great potential for becoming an alternative technique for industrial scale-up applications.
Sun, Yinnan; Yang, Kui; Cao, Qin; Sun, Jinde; Xia, Yu; Wang, Yinhang; Li, Wei; Ma, Chunhui; Liu, Shouxin
2017-07-11
A homogenate-assisted vacuum-powered bubble extraction (HVBE) method using ethanol was applied for extraction of flavonoids from Phyllostachys pubescens (P. pubescens) leaves. The mechanisms of homogenate-assisted extraction and vacuum-powered bubble generation were discussed in detail. Furthermore, a method for the rapid determination of flavonoids by HPLC was established. HVBE followed by HPLC was successfully applied for the extraction and quantification of four flavonoids in P. pubescens , including orientin, isoorientin, vitexin, and isovitexin. This method provides a fast and effective means for the preparation and determination of plant active components. Moreover, the on-line antioxidant capacity, including scavenging positive ion and negative ion free radical capacity of different fractions from the bamboo flavonoid extract was evaluated. Results showed that the scavenging DPPH ˙ free radical capacity of vitexin and isovitexin was larger than that of isoorientin and orientin. On the contrary, the scavenging ABTS⁺ ˙ free radical capacity of isoorientin and orientin was larger than that of vitexin and isovitexin.
Elshof, Lotte E; Tryfonidis, Konstantinos; Slaets, Leen; van Leeuwen-Stok, A Elise; Skinner, Victoria P; Dif, Nicolas; Pijnappel, Ruud M; Bijker, Nina; Rutgers, Emiel J Th; Wesseling, Jelle
2015-08-01
The current debate on overdiagnosis and overtreatment of screen-detected ductal carcinoma in situ (DCIS) urges the need for prospective studies to address this issue. A substantial number of DCIS lesions will never form a health hazard, particularly if it concerns non- to slow-growing low-grade DCIS. The LORD study aims to evaluate the safety of active surveillance in women with low-risk DCIS. This is a randomised, international multicentre, open-label, phase III non-inferiority trial, led by the Dutch Breast Cancer Research Group (BOOG 2014-04) and the European Organization for Research and Treatment of Cancer (EORTC-BCG 1401). Standard treatment will be compared to active surveillance in 1240 women aged ⩾ 45 years with asymptomatic, screen-detected, pure low-grade DCIS based on vacuum-assisted biopsies of microcalcifications only. Both study arms will be monitored with annual digital mammography for a period of 10 years. The primary end-point is 10-year ipsilateral invasive breast cancer free percentage. Secondary end-points include patient reported outcomes, diagnostic biopsy rate during follow-up, ipsilateral mastectomy rate and translational research. To explore interest in and feasibility of the LORD study we conducted a survey among EORTC and BOOG centres. A vast majority of EORTC and BOOG responding centres expressed interest in participation in the LORD study. The proposed study design is endorsed by nearly all centres. Copyright © 2015 The Authors. Published by Elsevier Ltd.. All rights reserved.
Agarwal, Ritesh; Khan, Ajmal; Aggarwal, Ashutosh N; Gupta, Dheeraj
2012-11-01
Fiberoptic bronchoscopy and lung biopsy are important diagnostic tools in patients with diffuse pulmonary infiltrates. However, these patients often have hypoxemic respiratory failure that makes this procedure hazardous. Noninvasive ventilation (NIV) has been shown to improve oxygenation in hypoxemic patients. To report the efficacy and safety of an innovative technique of NIV-assisted bronchoscopic lung biopsy in a small case-series of hypoxemic subjects with diffuse parenchymal infiltrates; also to systematically review the literature on NIV-assisted bronchoscopy. Subjects with bilateral diffuse parenchymal infiltrates and P(aO(2))/F(IO(2)) < 200 mm Hg underwent bronchoscopic lung biopsy under NIV support. NIV was initiated 10 min before the procedure and continued for 30 min after the procedure. The primary outcomes were performance of successful procedure and episodes of decline in S(pO(2)) < 90%. Secondary end points were the change in the respiratory and hemodynamic parameters during the procedure and occurrence of complications such as pneumothorax, hemorrhage, and endotracheal intubation. Six subjects, with a mean ± SD age of 44.5 ± 11.6 years, were included in the study. The median (interquartile range [IQR]) P(aO(2))/F(IO(2)) prior to lung biopsy was 164.5 mm Hg (146.3-176.3 mm Hg), and the median (IQR) inspiratory and expiratory positive airway pressures were 14 cm H(2)O (12-15 cm H(2)O) and 5 cm H(2)O. Fiberoptic bronchoscopy was well tolerated and all subjects maintained S(pO(2)) > 92% during the procedure. One subject required endotracheal intubation due to hemoptysis. A definite diagnosis was obtained in 5 of the 6 subjects. A repeat procedure was performed in one subject, which again yielded no diagnosis. No other periprocedural complications were encountered. NIV-assisted bronchoscopic lung biopsy is a novel method for obtaining diagnosis in hypoxemic patients with diffuse lung infiltrates. However, this approach should be reserved for centers with extensive experience in NIV. More studies are required to define the utility of this approach.
Isbarn, Hendrik; Briganti, Alberto; De Visschere, Pieter J L; Fütterer, Jurgen J; Ghadjar, Pirus; Giannarini, Gianluca; Ost, Piet; Ploussard, Guillaume; Sooriakumaran, Prasanna; Surcel, Christian I; van Oort, Inge M; Yossepowitch, Ofer; van den Bergh, Roderick C N
2015-04-01
Prostate biopsy (PB) is the gold standard for the diagnosis of prostate cancer (PCa). However, the optimal number of biopsy cores remains debatable. We sought to compare contemporary standard (10-12 cores) vs. saturation (=18 cores) schemes on initial as well as repeat PB. A non-systematic review of the literature was performed from 2000 through 2013. Studies of highest evidence (randomized controlled trials, prospective non-randomized studies, and retrospective reports of high quality) comparing standard vs saturation schemes on initial and repeat PB were evaluated. Outcome measures were overall PCa detection rate, detection rate of insignificant PCa, and procedure-associated morbidity. On initial PB, there is growing evidence that a saturation scheme is associated with a higher PCa detection rate compared to a standard one in men with lower PSA levels (<10 ng/ml), larger prostates (>40 cc), or lower PSA density values (<0.25 ng/ml/cc). However, these cut-offs are not uniform and differ among studies. Detection rates of insignificant PCa do not differ in a significant fashion between standard and saturation biopsies. On repeat PB, PCa detection rate is likewise higher with saturation protocols. Estimates of insignificant PCa vary widely due to differing definitions of insignificant disease. However, the rates of insignificant PCa appear to be comparable for the schemes in patients with only one prior negative biopsy, while saturation biopsy seems to detect more cases of insignificant PCa compared to standard biopsy in men with two or more prior negative biopsies. Very extensive sampling is associated with a high rate of acute urinary retention, whereas other severe adverse events, such as sepsis, appear not to occur more frequently with saturation schemes. Current evidence suggests that saturation schemes are associated with a higher PCa detection rate compared to standard ones on initial PB in men with lower PSA levels or larger prostates, and on repeat PB. Since most data are derived from retrospective studies, other endpoints such as detection rate of insignificant disease - especially on repeat PB - show broad variations throughout the literature and must, thus, be interpreted with caution. Future prospective controlled trials should be conducted to compare extended templates with newer techniques, such as image-guided sampling, in order to optimize PCa diagnostic strategy.
Qu, Hua-Wei; Liu, Hui; Cui, Zi-Lian; Jin, Xun-Bo; Zhao, Yong; Wang, Mu-Wen; Song, Wei; Zhang, Xin-Juan
2016-09-01
To improve the accuracy of prostate cancer (PCa) detection by focusing biopsy on the suspected lesion manifested by MRI with the total number of biopsy cores relatively unchanged. A prospective randomized analysis was performed on 262 cases of suspected PCa detected by multi-parametric MRI (mp-MRI), each with a single suspected lesion with 10 μg/L≤ PSA <20 μg/L. All the patients underwent targeted transrectal prostate biopsy guided by fusion imaging of MRI with transrectal ultrasonography (TRUS), using the 6X+6 strategy (6 cores in the suspected region and another 6 in the systematic prostate) for 134 cases and the traditional 12+2X method (12 cores in the systematic prostate and 2 in the suspected region) for the other 128. Comparisons were made between the two methods in the PCa detection rate in the cases of suspected lesion, total PCa detection rate, incidence of post-biopsy complications, and Gleason scores. Analyses were performed on the prostate imaging reporting and data system (PI-RADS) score, location, transverse section, and diameter of the suspected lesion. Both the total PCa detection rate and that in the cases of suspected lesion were significantly higher in the 6X+6 (44.8% and 37.3%) than in the 12+2X group (37.5% and 27.3%) (P<0.05). MRI showed that the suspected lesions were mostly (45%) located in the middle part of the prostate, the mean area of the transverse section was (0.48±0.11) cm2, and the mean diameter of the tumor was (8.51±2.21) mm. The results of biopsy showed that low-grade tumors (Gleason 3+3=6) accounted for 68% in the 6X+6 group and 71% in the 12+2X group. No statistically significant differences were found between the two groups in the incidence rate of post-biopsy complications. Compared with the traditional 12+2X method, for the suspected lesion manifested by mp-MRI, focusing biopsy on the suspected region with the 6X+6 strategy can achieve a higher PCa detection rate without increasing the incidence of complications.
Nafisi, Shahram
2006-01-01
Background Whether epidural analgesia for labor prolongs the active-first and second labor stages and increases the risk of vacuum-assisted delivery is a controversial topic. Our study was conducted to answer the question: does lumbar epidural analgesia with lidocaine affect the progress of labor in our obstetric population? Method 395 healthy, nulliparous women, at term, presented in spontaneous labor with a singleton vertex presentation. These patients were randomized to receive analgesia either, epidural with bolus doses of 1% lidocaine or intravenous, with meperidine 25 to 50 mg when their cervix was dilated to 4 centimeters. The duration of the active-first and second stages of labor and the neonatal apgar scores were recorded, in each patient. The total number of vacuum-assisted and cesarean deliveries were also measured. Results 197 women were randomized to the epidural group. 198 women were randomized to the single-dose intravenous meperidine group. There was no statistical difference in rates of vacuum-assisted delivery rate. Cesarean deliveries, as a consequence of fetal bradycardia or dystocia, did not differ significantly between the groups. Differences in the duration of the active-first and the second stages of labor were not statistically significant. The number of newborns with 1-min and 5-min Apgar scores less than 7, did not differ significantly between both analgesia groups. Conclusion Epidural analgesia with 1% lidocaine does not prolong the active-first and second stages of labor and does not increase vacuum-assisted or cesarean delivery rate. PMID:17176461
Liang, Yuan-Chang; Lo, Ya-Ru; Wang, Chein-Chung; Xu, Nian-Cih
2018-01-01
ZnO-ZnS core-shell nanorods are synthesized by combining the hydrothermal method and vacuum sputtering. The core-shell nanorods with variable ZnS shell thickness (7–46 nm) are synthesized by varying ZnS sputtering duration. Structural analyses demonstrated that the as-grown ZnS shell layers are well crystallized with preferring growth direction of ZnS (002). The sputtering-assisted synthesized ZnO-ZnS core-shell nanorods are in a wurtzite structure. Moreover, photoluminance spectral analysis indicated that the introduction of a ZnS shell layer improved the photoexcited electron and hole separation efficiency of the ZnO nanorods. A strong correlation between effective charge separation and the shell thickness aids the photocatalytic behavior of the nanorods and improves their photoresponsive nature. The results of comparative degradation efficiency toward methylene blue showed that the ZnO-ZnS nanorods with the shell thickness of approximately 17 nm have the highest photocatalytic performance than the ZnO-ZnS nanorods with other shell layer thicknesses. The highly reusable catalytic efficiency and superior photocatalytic performance of the ZnO-ZnS nanorods with 17 nm-thick ZnS shell layer supports their potential for environmental applications. PMID:29316671
Vacuum-assisted fluid flow in microchannels to pattern substrates and cells.
Shrirao, Anil B; Kung, Frank H; Yip, Derek; Cho, Cheul H; Townes-Anderson, Ellen
2014-09-01
Substrate and cell patterning are widely used techniques in cell biology to study cell-to-cell and cell-substrate interactions. Conventional patterning techniques work well only with simple shapes, small areas and selected bio-materials. This paper describes a method to distribute cell suspensions as well as substrate solutions into complex, long, closed (dead-end) polydimethylsiloxane (PDMS) microchannels using negative pressure. Our method builds upon a previous vacuum-assisted method used for micromolding (Jeon et al 1999 Adv. Mater 11 946) and successfully patterned collagen-I, fibronectin and Sal-1 substrates on glass and polystyrene surfaces, filling microchannels with lengths up to 120 mm and covering areas up to 13 × 10 mm(2). Vacuum-patterned substrates were subsequently used to culture mammalian PC12 and fibroblast cells and amphibian neurons. Cells were also patterned directly by injecting cell suspensions into microchannels using vacuum. Fibroblast and neuronal cells patterned using vacuum showed normal growth and minimal cell death indicating no adverse effects of vacuum on cells. Our method fills reversibly sealed PDMS microchannels. This enables the user to remove the PDMS microchannel cast and access the patterned biomaterial or cells for further experimental purposes. Overall, this is a straightforward technique that has broad applicability for cell biology.
Vacuum-assisted Fluid Flow in Microchannels to Pattern Substrates and Cells
Shrirao, Anil B.; Kung, Frank H.; Yip, Derek; Cho, Cheul H.; Townes-Anderson, Ellen
2014-01-01
Substrate and cell patterning are widely used techniques in cell biology to study cell-to-cell and cell-to-substrate interactions. Conventional patterning techniques work well only with simple shapes, small areas and selected bio-materials. This paper describes a method to distribute cell suspensions as well as substrate solutions into complex, long, closed (dead-end) polydimethylsiloxane (PDMS) microchannels using negative pressure. Our method builds upon a previous vacuum-assisted method used for micromolding (Jeon, Choi et al. 1999) and successfully patterned collagen-I, fibronectin and Sal-1 substrates on glass and polystyrene surfaces, filling microchannels with lengths up to 120 mm and covering areas up to 13 × 10 mm2. Vacuum-patterned substrates were subsequently used to culture mammalian PC12 and fibroblast cells and amphibian neurons. Cells were also patterned directly by injecting cell suspensions into microchannels using vacuum. Fibroblast and neuronal cells patterned using vacuum showed normal growth and minimal cell death indicating no adverse effects of vacuum on cells. Our method fills reversibly sealed PDMS microchannels. This enables the user to remove the PDMS microchannel cast and access the patterned biomaterial or cells for further experimental purposes. Overall, this is a straightforward technique that has broad applicability for cell biology. PMID:24989641
Percutaneous CT-guided biopsy of the spine: results of 430 biopsies
Rimondi, Eugenio; Errani, Costantino; Bianchi, Giuseppe; Casadei, Roberto; Alberghini, Marco; Malaguti, Maria Cristina; Rossi, Giuseppe; Durante, Stefano; Mercuri, Mario
2008-01-01
Biopsies of lesions in the spine are often challenging procedures with significant risk of complications. CT-guided needle biopsies could lower these risks but uncertainties still exist about the diagnostic accuracy. Aim of this retrospective study was to evaluate the diagnostic accuracy of CT-guided needle biopsies for bone lesions of the spine. We retrieved the results of 430 core needle biopsies carried out over the past fifteen years at the authors’ institute and examined the results obtained. Of the 430 biopsies performed, in 401 cases the right diagnosis was made with the first CT-guided needle biopsy (93.3% accuracy rate). Highest accuracy rates were obtained in primary and secondary malignant lesions. Most false negative results were found in cervical lesions and in benign, pseudotumoral, inflammatory, and systemic pathologies. There were only 9 complications (5 transient paresis, 4 haematomas that resolved spontaneously) that had no influence on the treatment strategy, nor on the patient’s outcome. In conclusion we can assert that this technique is reliable and safe and should be considered the gold standard in biopsies of the spine. PMID:18463900
DOE Office of Scientific and Technical Information (OSTI.GOV)
Welch, B. T., E-mail: Welch.brian@mayo.edu; Eiken, P. W.; Atwell, T. D.
PurposeMesothelioma has been considered a difficult pathologic diagnosis to achieve via image-guided core needle biopsy. The purpose of this study was to assess the diagnostic sensitivity of percutaneous image-guided biopsy for diagnosis of pleural mesothelioma.Materials and MethodsRetrospective review was performed to identify patients with a confirmed diagnosis of pleural mesothelioma and who underwent image-guided needle biopsy between January 1, 2002, and January 1, 2016. Thirty-two patients with pleural mesothelioma were identified and included for analysis in 33 image-guided biopsy procedures. Patient, procedural, and pathologic characteristics were recorded. Complications were characterized via standardized nomenclature [Common Terminology for Clinically Adverse Events (CTCAE)].ResultsPercutaneousmore » image-guided biopsy was associated with an overall sensitivity of 81%. No CTCAE clinically significant complications were observed. No image-guided procedures were complicated by pneumothorax or necessitated chest tube placement. No patients had tumor seeding of the biopsy tract.ConclusionPercutaneous image-guided biopsy can achieve high sensitivity for pathologic diagnosis of pleural mesothelioma with a low procedural complication rate, potentially obviating need for surgical biopsy.« less
Surface oxidation of GaN(0001): Nitrogen plasma-assisted cleaning for ultrahigh vacuum applications
DOE Office of Scientific and Technical Information (OSTI.GOV)
Gangopadhyay, Subhashis; Schmidt, Thomas, E-mail: tschmidt@ifp.uni-bremen.de; Kruse, Carsten
The cleaning of metal-organic vapor-phase epitaxial GaN(0001) template layers grown on sapphire has been investigated. Different procedures, performed under ultrahigh vacuum conditions, including degassing and exposure to active nitrogen from a radio frequency nitrogen plasma source have been compared. For this purpose, x-ray photoelectron spectroscopy, reflection high-energy electron diffraction, and scanning tunneling microscopy have been employed in order to assess chemical as well as structural and morphological surface properties. Initial degassing at 600 °C under ultrahigh vacuum conditions only partially eliminates the surface contaminants. In contrast to plasma assisted nitrogen cleaning at temperatures as low as 300 °C, active-nitrogen exposure at temperaturesmore » as high as 700 °C removes the majority of oxide species from the surface. However, extended high-temperature active-nitrogen cleaning leads to severe surface roughening. Optimum results regarding both the removal of surface oxides as well as the surface structural and morphological quality have been achieved for a combination of initial low-temperature plasma-assisted cleaning, followed by a rapid nitrogen plasma-assisted cleaning at high temperature.« less
An HR-MAS MR Metabolomics Study on Breast Tissues Obtained with Core Needle Biopsy
Cho, Nariya; Chang, Jung Min; Koo, Hye Ryoung; Yi, Ann; Kim, Hyeonjin; Park, Sunghyouk; Moon, Woo Kyung
2011-01-01
Background Much research has been devoted to the development of new breast cancer diagnostic measures, including those involving high-resolution magic angle spinning (HR-MAS) magnetic resonance (MR) spectroscopic techniques. Previous HR-MAS MR results have been obtained from post-surgery samples, which limits their direct clinical applicability. Methodology/Principal Findings In the present study, we performed HR-MAS MR spectroscopic studies on 31 breast tissue samples (13 cancer and 18 non-cancer) obtained by percutaneous core needle biopsy. We showed that cancer and non-cancer samples can be discriminated very well with Orthogonal Projections to Latent Structure-Discriminant Analysis (OPLS-DA) multivariate model on the MR spectra. A subsequent blind test showed 69% sensitivity and 94% specificity in the prediction of the cancer status. A spectral analysis showed that in cancer cells, taurine- and choline-containing compounds are elevated. Our approach, additionally, could predict the progesterone receptor statuses of the cancer patients. Conclusions/Significance HR-MAS MR metabolomics on intact breast tissues obtained by core needle biopsy may have a potential to be used as a complement to the current diagnostic and prognostic measures for breast cancers. PMID:22028780
Washington, Samuel L; Bonham, Michael; Whitson, Jared M; Cowan, Janet E; Carroll, Peter R
2012-07-01
Study Type - Diagnostic (exploratory cohort) Level of Evidence 2b What's known on the subject? and What does the study add? The widespread use of serum PSA testing followed by TRUS-guided biopsy have resulted in profound prostate cancer stage migration with many patients presenting with focal rather than multifocal disease. There is increasing interest in the use of focal rather than whole-gland treatment. However, current biopsy schemes may still miss cancer or, even when cancer is identified, its extent or grade might not be accurately characterized. In order for focal therapy to be effective, the area of highest tumour volume and/or grade needs to localized accurately. The aim of this study was to assess how well biopsy, as currently performed, locates the focus of highest prostate cancer volume and/or grade. To evaluate the ability of transrectal ultrasonography (TRUS)-guided extended core biopsy to identify the dominant tumour accurately in men with early stage prostate cancer. Patients with early stage, low-risk prostate cancer who subsequently underwent radical prostatectomy (RP) and had complete surgical specimens were identified. Re-review was performed by a single uropathologist using ImageJ software to identify tumour location, dominant grade (DG) and dominant volume (DV). Pathology findings were then compared with biopsy results. A total of 51 men with early stage, low-risk prostate cancer, who had undergone RP, had complete specimens for review and a median of 15 biopsy cores taken for diagnosis and grading. Sixteen men had a single diagnostic biopsy, 21 had one repeat biopsy, and 14 had two or more repeat biopsies. Compared with surgical findings, biopsy correctly identified the sextant with the largest tumour volume in 55% (95% CI 0.5-0.6) of specimens and the highest grade in 37% (95 CI 0.3-0.5). No demographic or clinical factors were significantly associated with identification of DG. Interval between last biopsy and RP, total tissue length taken and total length of tumour identified were significantly associated with correct identification of DV. Our findings show that TRUS-guided biopsy detects and localizes DV better than it does DG. Even with an extended scheme, TRUS-guided biopsy does not reliably identify dominant cancer location in this low-risk cohort of men with early stage prostate cancer. TRUS-guided biopsy may perform better in similar men with low stage, but higher volume disease. © 2011 BJU INTERNATIONAL.
Matrix Characterization and Development for the Vacuum Assisted Resin Transfer Molding Process
NASA Technical Reports Server (NTRS)
Grimsley, B. W.; Hubert, P.; Hou, T. H.; Cano, R. J.; Loos, A. C.; Pipes, R. B.
2001-01-01
The curing kinetics and viscosity of an epoxy resin system, SI-ZG-5A, have been characterized for application in the vacuum assisted resin transfer molding (VARTM) process. Impregnation of a typical carbon fiber perform provided the test bed for the characterization. Process simulations were carried out using the process model, COMPRO, to examine heat transfer and curing kinetics for a fully impregnated panel, neglecting resin flow. The predicted viscosity profile and final degree of cure were found to be in good agreement with experimental observations.
Stabilization of lunar core samples
NASA Technical Reports Server (NTRS)
Nagle, J. S.; Duke, M. B.
1974-01-01
Processing of lunar cores includes: (1) careful dissection for study of loose fines, and (2) stabilization of the residue by peeling and impregnation. The newly developed technique for preparing thin peels of lunar cores requires application of the methacrylate adhesive to a backing strip, before taking the peel. To ensure complete impregnation of the very fine, dry lunar soil, the low-viscosity epoxy, Araldite 506, is gently flowed onto the core, under vacuum.
NASA Technical Reports Server (NTRS)
Poberezhskiy, Ilya Y.; Meras, Patrick; Chang, Daniel H.; Spiers, Gary D.
2007-01-01
This slide presentation reviews a method for refilling and connectorization of hollow core photonic crystal fiber gas reference cells. Thees hollow-core photonic crystal fiber allow optical propagation in air or vacuum and are for use as gas reference cell is proposed and demonstrated. It relies on torch-sealing a quartz filling tube connected to a mechanical splice between regular and hollow-core fibers.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Freytag, Svend O., E-mail: sfreyta1@hfhs.org; Stricker, Hans; Lu, Mei
Purpose: To assess the safety and efficacy of combining oncolytic adenovirus-mediated cytotoxic gene therapy (OAMCGT) with intensity modulated radiation therapy (IMRT) in intermediate-risk prostate cancer. Methods and Materials: Forty-four men with intermediate-risk prostate cancer were randomly assigned to receive either OAMCGT plus IMRT (arm 1; n=21) or IMRT only (arm 2; n=23). The primary phase 2 endpoint was acute (≤90 days) toxicity. Secondary endpoints included quality of life (QOL), prostate biopsy (12-core) positivity at 2 years, freedom from biochemical/clinical failure (FFF), freedom from metastases, and survival. Results: Men in arm 1 exhibited a greater incidence of low-grade influenza-like symptoms, transaminitis,more » neutropenia, and thrombocytopenia than men in arm 2. There were no significant differences in gastrointestinal or genitourinary events or QOL between the 2 arms. Two-year prostate biopsies were obtained from 37 men (84%). Thirty-three percent of men in arm 1 were biopsy-positive versus 58% in arm 2, representing a 42% relative reduction in biopsy positivity in the investigational arm (P=.13). There was a 60% relative reduction in biopsy positivity in the investigational arm in men with <50% positive biopsy cores at baseline (P=.07). To date, 1 patient in each arm exhibited biochemical failure (arm 1, 4.8%; arm 2, 4.3%). No patient developed hormone-refractory or metastatic disease, and none has died from prostate cancer. Conclusions: Combining OAMCGT with IMRT does not exacerbate the most common side effects of prostate radiation therapy and suggests a clinically meaningful reduction in positive biopsy results at 2 years in men with intermediate-risk prostate cancer.« less
Shafer, Morgan W.; Unterberg, Ezekial A.; Wingen, Andreas; ...
2014-12-29
Recent observations on DIII-D have advanced the understanding of plasma response to applied resonant magnetic perturbations (RMPs) in both H-mode and L-mode plasmas. Three distinct 3D features localized in minor radius are imaged via filtered soft x-ray emission: (i) the formation of lobes extending from the unperturbed separatrix in the X-point region at the plasma boundary, (ii) helical kink-like perturbations in the steep-gradient region inside the separatrix, and (iii) amplified islands in the core of a low-rotation L-mode plasma. In this study, these measurements are used to test and to validate plasma response models, which are crucial for providing predictivemore » capability of edge-localized mode control. In particular, vacuum and two-fluid resistive magnetohydrodynamic(MHD) responses are tested in the regions of these measurements. At the plasma boundary in H-mode discharges with n = 3 RMPs applied, measurements compare well to vacuum-field calculations that predict lobe structures. Yet in the steep-gradient region, measurements agree better with calculations from the linear resistive two-fluid MHD code, M3D-C1. Relative to the vacuum fields, the resistive two-fluid MHD calculations show a reduction in the pitch-resonant components of the normal magnetic field (screening), and amplification of non-resonant components associated with ideal kink modes. However, the calculations still over-predict the amplitude of the measuredperturbation by a factor of 4. In a slowly rotating L-mode plasma with n = 1 RMPs, core islands are observed amplified from vacuum predictions. Finally, these results indicate that while the vacuum approach describes measurements in the edge region well, it is important to include effects of extended MHD in the pedestal and deeper in the plasma core.« less
[Caesarean section with vacuum extraction of the head].
Dimitrov, A; Pavlova, E; Krŭsteva, K; Nikolov, A
2008-01-01
The aim of the study is to investigate the benefits and the limits in using the soft cup vacuum extractor on the fetal scalp during the caesarean section. The prospective study includes 19 cases of caesarean sections (group A), with vacuum assisted delivery using the soft cup vacuum extractor on the fetal scalp (diameter 6 cm) and 25 cases (group B) of caesarean sections with usual, manual extraction of the head assisted by fundal compression. All of the patients had undergone a planned caesarean section on term in absence of uterine activity and preserved amniotic membranes. Our results doesn't show differences in the Apgar score on the first and 5-th minute in the newborns of the two groups. The duration of the scalp traction was significantly shorter (30 +/- 4 sec) in comparison to the classical manual extraction (53 +/- 21 sec). The mean duration for applying the vacuum cup was 10 sec and 25 sec for tractions. The total blood loose and total duration of the caesarean sections were shorter than in the control group. The applied traction with the vacuum cup was sufficient for head extraction and there was no need for additional fundal compression. In conclusion we consider that the extraction of the fetal head in high position in caesarean section with vacuum extractor is an easy, non traumatic and rapid method which can put away the need of rough and prolonged fundal compression and its consequences.
Peres, Alexandre; Barranger, Emmanuel; Becette, Véronique; Boudinet, Alain; Guinebretiere, Jean-Marc; Cherel, Pascal
2012-06-01
Flat epithelial atypia (FEA) is a borderline lesion that might represent an early stage in the development of certain low-grade carcinomas in situ and invasive cancers. There are no guidelines on its management. Our objectives were to determine the upgrade to malignancy rate and identify a subpopulation of patients that might undergo just mammographic surveillance. We retrospectively reviewed the data for 271 FEA cases among 5,555 breast core biopsies obtained over a 7-year period (January 2003-2010). We collated clinical data (age, history of cancer, menopausal status), radiological data (lesion type, size, Bi-Rads category), technical data (number of biopsies, needle gauge, excision quality) and histological data and sought correlations between these factors and upgrade rate. The 271 FEA comprised 128 cases of pure FEA, 135 cases of FEA + atypical ductal hyperplasia, and 8 cases of FEA + atypical lobular hyperplasia. Overall, 184 patients underwent surgery and 46 mammographic surveillance. Surgery detected 34 cases of malignancy (23 CIS, 7 invasive cancers, and 4 mixed cases) giving a 15% upgrade rate. Quality of excision was the only factor associated with under-diagnosis. The presence of FEA at biopsy warrants surgery.
Comparison of histologic diagnosis between stereotactic core needle biopsy and open surgical biopsy.
Bauer, R L; Sung, J; Eckhert, K H; Koul, A; Castillo, N B; Nemoto, T
1997-06-01
This study correlates the histologic findings of stereotactic core needle biopsy (SCNB) with open surgical biopsy (OSB) and identifies which lesions can be treated definitively based only on the SCNB histology. Women who underwent SCNB between July 1, 1993, and January 1, 1969, were identified by retrospective chart review. Mammographic (MGM) lesions found by SCNB to be ductal or lobular hyperplasia with atypia, or carcinoma underwent OSB. When the histologic findings by SCNB were inconsistent with the MGM findings, the lesion also underwent OSB. 799 women underwent SCNB with 96 (12%) of these going on to OSB. MGM findings in the 92 who presented without a palpable mass included microcalcifications (MCS) in 39, mass in 47, MCS and mass in 7, and tissue distortion in 3. One hundred one breast lesions biopsied first by SCNB, then by OSB were correlated histologically. Sensitivity of SCNB is 89%, with a specificity of 94%. Eight-four women (88%) were able to have definitive treatment at time of OSB because of prior SCNB, and 703/799 (88%) of women were spared OSB entirely. SCNB accurately identifies benign breast histology and invasive cancers in women with MGM abnormalities, a distinct advantage over fine needle aspiration cytology. SCNB does not reliably identify women with DCIS and invasion. All women with SCNB diagnosis of ductal or lobular atypia should also undergo OSB.
Raj, Manish; Kumar, Sunil; Singh, Pulkesh; Kumar, Dinesh; Singh, Jasveer; Deep, Akash
2016-01-01
Introduction Management of compound grade III fractures of both bone leg includes external stabilization for long period, followed by various soft tissue coverage procedures. Primary interlocking of tibia had been also done with variable results. External fixation for long time without any bone loss often leads to infected nonunion, loss of reduction, pin tract infection and failure of fixation, primary interlocking in compound grade III fractures had shown high medullary infection rate. We managed all cases of compound grade III A/B fractures with primary external fixation, simultaneous wound management using vacuum assisted closure (VAC) followed by early conversion to interlocking within 2 weeks of fixator application. Aim To determine the effectiveness of vacuum assisted closure (VAC) for the early conversion of external fixator to definitive interlocking in open fractures of the both bone leg. Materials and Methods In current study we selected 84 cases of compound grade IIIA/B diaphyseal fractures of both bone leg during period of May 2010 to September 2013. We managed these cases by immediate debridement and application of external fixation followed by repeated debridement, application of vacuum assisted closure (VAC) and conversion to interlocking within two weeks. Results Out of 84 cases union was achieved in 80(95%) of cases with definitive tibial interlocking. Excellent to good result were obtained in 77(91.8%) of cases and fair to poor result seen in rest of 7(8.2%) of cases according to modified Ketenjian’s criteria. 5 out of these 7 poor result group cases were from Compound Grade III B group to start with. Deep infection rate in our series were 7% i.e. total 6 cases and 4 out of these were from compound Grade III B group to start with. Conclusion Vacuum assisted closure (VAC) give a good help for rapid closure of the wound and help in early conversion to definitive intramedullary nailing. Reamed nail could well be used in compound grade IIIA/B fractures without increasing the risk of infection. It gives better stability to fracture site and lessen the risk of implant failure. PMID:27042541
A Vacuum in Political and Economic Labor Policy?
ERIC Educational Resources Information Center
Karasek, Robert A.
2004-01-01
A vacuum is arising in the social policy of advanced countries. It is due to the fact that both of the currently dominant bases for social policy, market-oriented policy, and its presumed antagonist, welfare state policy, have the same and an insufficiently broad production value model at their core. The solution is to create a true new…
Valerio, Massimo; McCartan, Neil; Freeman, Alex; Punwani, Shonit; Emberton, Mark; Ahmed, Hashim U
2015-10-01
Targeted biopsy based on cognitive or software magnetic resonance imaging (MRI) to transrectal ultrasound registration seems to increase the detection rate of clinically significant prostate cancer as compared with standard biopsy. However, these strategies have not been directly compared against an accurate test yet. The aim of this study was to obtain pilot data on the diagnostic ability of visually directed targeted biopsy vs. software-based targeted biopsy, considering transperineal template mapping (TPM) biopsy as the reference test. Prospective paired cohort study included 50 consecutive men undergoing TPM with one or more visible targets detected on preoperative multiparametric MRI. Targets were contoured on the Biojet software. Patients initially underwent software-based targeted biopsies, then visually directed targeted biopsies, and finally systematic TPM. The detection rate of clinically significant disease (Gleason score ≥3+4 and/or maximum cancer core length ≥4mm) of one strategy against another was compared by 3×3 contingency tables. Secondary analyses were performed using a less stringent threshold of significance (Gleason score ≥4+3 and/or maximum cancer core length ≥6mm). Median age was 68 (interquartile range: 63-73); median prostate-specific antigen level was 7.9ng/mL (6.4-10.2). A total of 79 targets were detected with a mean of 1.6 targets per patient. Of these, 27 (34%), 28 (35%), and 24 (31%) were scored 3, 4, and 5, respectively. At a patient level, the detection rate was 32 (64%), 34 (68%), and 38 (76%) for visually directed targeted, software-based biopsy, and TPM, respectively. Combining the 2 targeted strategies would have led to detection rate of 39 (78%). At a patient level and at a target level, software-based targeted biopsy found more clinically significant diseases than did visually directed targeted biopsy, although this was not statistically significant (22% vs. 14%, P = 0.48; 51.9% vs. 44.3%, P = 0.24). Secondary analysis showed similar results. Based on these findings, a paired cohort study enrolling at least 257 men would verify whether this difference is statistically significant. The diagnostic ability of software-based targeted biopsy and visually directed targeted biopsy seems almost comparable, although utility and efficiency both seem to be slightly in favor of the software-based strategy. Ongoing trials are sufficiently powered to prove or disprove these findings. Copyright © 2015 Elsevier Inc. All rights reserved.
Arslan, G; Ceken, K; Cubuk, M; Ozkaynak, C; Lüleci, E
2001-01-01
To review the prevalence and location of vertebral pneumatocysts and evaluate the CT findings of these benign lesions. Retrospectively we reviewed CT images of 89 patients with suspected disc disease during a 6-month period. Distinctive CT pattern of intraosseous pneumatocysts involving the cervical, thoracic and lumbar spine was found. In 8 patients (9%), 10 vertebral pneumatocysts were detected. Five were located in the vertebral body and 4 of these were associated with vacuum phenomenon in adjacent intervertebral discs. Five were located near the facet joint and all were associated with vacuum phenomenon in adjacent facet joint. Intraosseous pneumatocyst is a benign lesion, therefore biopsy and follow-up are unnecessary. Although vertebral pneumatocysts seem to be uncommon with a few reported cases, this study shows them to be more frequent than previously thought.
Lee, Ban Seok; Cho, Chang-Min; Jung, Min Kyu; Jang, Jung Sik; Bae, Han Ik
2017-07-15
The superiority of endoscopic ultrasound-guided fine needle biopsy (EUS-FNB) over EUS-guided fine needle aspiration (EUS-FNA) remains controversial. Given the lack of studies analyzing histologic specimens acquired from EUS-FNB or EUS-FNA, we compared the proportion of the histologic core obtained from both techniques. A total of 58 consecutive patients with solid mass lesions were enrolled and randomly assigned to the EUS-FNA or EUS-FNB groups. The opposite needle was used after the failure of core tissue acquisition using the initial needle with up to three passes. Using computerized analyses of the scanned histologic slide, the overall area and the area of the histologic core portion in specimens obtained by the two techniques were compared. No significant differences were identified between the two groups with respect to demographic and clinical characteristics. Fewer needle passes were required to obtain core specimens in the FNB group (p<0.001). There were no differences in the proportion of histologic core (11.8%±19.5% vs 8.0%±11.1%, p=0.376) or in the diagnostic accuracy (80.6% vs 81.5%, p=0.935) between two groups. The proportion of histologic core and the diagnostic accuracy were comparable between the FNB and FNA groups. However, fewer needle passes were required to establish an accurate diagnosis in EUS-FNB.
Apparatus and Method for Increasing the Diameter of Metal Alloy Wires Within a Molten Metal Pool
Hartman, Alan D.; Argetsinger, Edward R.; Hansen, Jeffrey S.; Paige, Jack I.; King, Paul E.; Turner, Paul C.
2002-01-29
In a dip forming process the core material to be coated is introduced directly into a source block of coating material eliminating the need for a bushing entrance component. The process containment vessel or crucible is heated so that only a portion of the coating material becomes molten, leaving a solid portion of material as the entrance port of, and seal around, the core material. The crucible can contain molten and solid metals and is especially useful when coating core material with reactive metals. The source block of coating material has been machined to include a close tolerance hole of a size and shape to closely fit the core material. The core material moves first through the solid portion of the source block of coating material where the close tolerance hole has been machined, then through a solid/molten interface, and finally through the molten phase where the diameter of the core material is increased. The crucible may or may not require water-cooling depending upon the type of material used in crucible construction. The system may operate under vacuum, partial vacuum, atmospheric pressure, or positive pressure depending upon the type of source material being used.
Apparatus and method for increasing the diameter of metal alloy wires within a molten metal pool
Hartman, Alan D.; Argetsinger, Edward R.; Hansen, Jeffrey S.; Paige, Jack I.; King, Paul E.; Turner, Paul C.
2002-01-29
In a dip forming process the core material to be coated is introduced directly into a source block of coating material eliminating the need for a bushing entrance component. The process containment vessel or crucible is heated so that only a portion of the coating material becomes molten, leaving a solid portion of material as the entrance port of, and seal around, the core material. The crucible can contain molten and solid metals and is especially useful when coating core material with reactive metals. The source block of coating material has been machined to include a close tolerance hole of a size and shape to closely fit the core material. The core material moves first through the solid portion of the source block of coating material where the close tolerance hole has been machined, then through a solid/molten interface, and finally through the molten phase where the diameter of the core material is increased. The crucible may or may not require water-cooling depending upon the type of material used in crucible construction. The system may operate under vacuum, partial vacuum, atmospheric pressure, or positive pressure depending upon the type of source material being used.
Rui, Y; Han, M; Zhou, W; He, Q; Li, H; Li, P; Zhang, F; Shi, Y; Su, X
2018-06-06
To determine true negatives and characterise the variables associated with false-negative results when interpreting non-malignant results of computed tomography (CT)-guided lung biopsy. Nine hundred and fifty patients with initial non-malignant findings on their first transthoracic CT-guided core-needle biopsy (TTNB) were included in the study. Initial biopsy results were compared to definitive diagnoses established later. The negative predictive value (NPV) of non-malignant diseases upon initial TTNB was 83.6%. When the biopsy results indicated specific infection or benign tumour (n=225, 26.1%), they all were confirmed true negative for malignancy later. Only one inconclusive "granuloma" diagnosis was false negative. All 141 patients (141/861, 16.4%) who were false negative for malignancy were from the "infection not otherwise specified (NOS)", "inflammatory diseases", or "inconclusive" groups. Age (p=0.002), cancer history (p<0.001), target size (p=0.003), and pneumothorax during lung biopsy (p=0.003) were found to be significant predictors of false-negative results; 47.6% (410/861) of patients underwent additional invasive examinations to reach a final diagnosis. Ultimately, 52.7% (216/410) were successfully diagnosed. Specific infection, benign tumour, and granulomatous inflammation of first TTNBs were mostly true negative. Older age, history of cancer, larger target size, and pneumothorax were highly predictive of false-negative results for malignancies. In such cases, additional invasive examinations were frequently necessary to obtain final diagnoses. Copyright © 2018 The Royal College of Radiologists. Published by Elsevier Ltd. All rights reserved.
Azlan, C A; Mohd Nasir, N F; Saifizul, A A; Faizul, M S; Ng, K H; Abdullah, B J J
2007-12-01
Percutaneous image-guided needle biopsy is typically performed in highly vascular organs or in tumours with rich macroscopic and microscopic blood supply. The main risks related to this procedure are haemorrhage and implantation of tumour cells in the needle tract after the biopsy needle is withdrawn. From numerous conducted studies, it was found that heating the needle tract using alternating current in radiofrequency (RF) range has a potential to minimize these effects. However, this solution requires the use of specially designed needles, which would make the procedure relatively expensive and complicated. Thus, we propose a simple solution by using readily available coaxial core biopsy needles connected to a radiofrequency ablation (RFA) generator. In order to do so, we have designed and developed an adapter to interface between these two devices. For evaluation purpose, we used a bovine liver as a sample tissue. The experimental procedure was done to study the effect of different parameter settings on the size of coagulation necrosis caused by the RF current heating on the subject. The delivery of the RF energy was varied by changing the values for delivered power, power delivery duration, and insertion depth. The results showed that the size of the coagulation necrosis is affected by all of the parameters tested. In general, the size of the region is enlarged with higher delivery of RF power, longer duration of power delivery, and shallower needle insertion and become relatively constant after a certain value. We also found that the solution proposed provides a low cost and practical way to minimizes unwanted post-biopsy effects.
Pishvar, Maya; Amirkhosravi, Mehrad; Altan, M Cengiz
2018-05-17
This work demonstrates a protocol to improve the quality of composite laminates fabricated by wet lay-up vacuum bag processes using the recently developed magnet assisted composite manufacturing (MACM) technique. In this technique, permanent magnets are utilized to apply a sufficiently high consolidation pressure during the curing stage. To enhance the intensity of the magnetic field, and thus, to increase the magnetic compaction pressure, the magnets are placed on a magnetic top plate. First, the entire procedure of preparing the composite lay-up on a magnetic bottom steel plate using the conventional wet lay-up vacuum bag process is described. Second, placement of a set of Neodymium-Iron-Boron permanent magnets, arranged in alternating polarity, on the vacuum bag is illustrated. Next, the experimental procedures to measure the magnetic compaction pressure and volume fractions of the composite constituents are presented. Finally, methods used to characterize microstructure and mechanical properties of composite laminates are discussed in detail. The results prove the effectiveness of the MACM method in improving the quality of wet lay-up vacuum bag laminates. This method does not require large capital investment for tooling or equipment and can also be used to consolidate geometrically complex composite parts by placing the magnets on a matching top mold positioned on the vacuum bag.
Shin, Hankei; Mori, Mitsuharu; Matayoshi, Toru; Suzuki, Ryo; Yozu, Ryohei
2004-08-01
A 53-year-old man sustained hemodynamic collapse due to a huge right atrial tumor and was transferred to our hospital and underwent a life-saving emergency operation. The tumor arose from the inferolateral wall of the right atrium, occupying almost the whole right atrial cavity and obstructing not only the inflow of the right ventricle but also the orifice of the inferior vena cava. Venous cannulation via the right atrial wall and placing a snare around the inferior vena cava were impossible. With a cardiopulmonary bypass using vacuum-assisted venous drainage, the tumor was successfully resected and the tricuspid valve was replaced with a bioprosthetic valve without snaring the inferior vena cava. Postoperative histological examination demonstrated the tumor to be a large B-cell non-Hodgkin type malignant lymphoma. When the tumor is large and it is difficult to establish total cardiopulmonary bypass, the vacuum-assisted cardiopulmonary bypass is a useful option. This can achieve a bloodless operative field and is not blocked by the incoming air, due to the venous drainage being continually pressure-regulated.
Performance of the Satellite Test Assistant Robot in JPL's Space Simulation Facility
NASA Technical Reports Server (NTRS)
Mcaffee, Douglas; Long, Mark; Johnson, Ken; Siebes, Georg
1995-01-01
An innovative new telerobotic inspection system called STAR (the Satellite Test Assistant Robot) has been developed to assist engineers as they test new spacecraft designs in simulated space environments. STAR operates inside the ultra-cold, high-vacuum, test chambers and provides engineers seated at a remote Operator Control Station (OCS) with high resolution video and infrared (IR) images of the flight articles under test. STAR was successfully proof tested in JPL's 25-ft (7.6-m) Space Simulation Chamber where temperatures ranged from +85 C to -190 C and vacuum levels reached 5.1 x 10(exp -6) torr. STAR's IR Camera was used to thermally map the entire interior of the chamber for the first time. STAR also made several unexpected and important discoveries about the thermal processes occurring within the chamber. Using a calibrated test fixture arrayed with ten sample spacecraft materials, the IR camera was shown to produce highly accurate surface temperature data. This paper outlines STAR's design and reports on significant results from the thermal vacuum chamber test.
Contemporary management of benign liver tumors.
Gibbs, John F; Litwin, Alan M; Kahlenberg, Morton S
2004-04-01
Benign lesions of the liver represent diagnostic dilemmas, clinically and radiographically; however, certain clues can help the extensive differential diagnosis of both benign and malignant processes. Hemangiomas and simple cysts have very distinct and very specific radiographic characteristics, and if diagnosed, no further work-up is necessary. The remaining benign lesions have significant overlap, even though there are some more common characteristics to each of the entities. Still, differentiation of any particular lesion outside simple cysts or hemangioma may be difficult. It is reasonable and relatively simple, with minimal invasiveness, to perform US- or CT-guided, percutaneous core-needle biopsies. It is recommended that core biopsies be performed, because many of the benign entities have some overlapping histologic features, and if fine-needle aspirations are performed, a definitive diagnosis may be difficult to obtain. A definitive pathological diagnosis still cannot be made in some cases, even after needle biopsy. Therefore, a surgical resection or wedge resection may be necessary if a benign process cannot be definitively ruled out.
Gentileschi, Stefano; Servillo, Maria; D'Ettorre, Marco; Salgarello, Marzia
2016-04-01
Body contouring by means of minimally invasive procedures is a growing trend. Current approaches to body contouring often involve a combination of surgical techniques (eg, laser-assisted liposuction) and a series of noninvasive device-based treatments aimed at accelerating recovery and improving aesthetic outcomes. In this case study, we describe a 38-year-old woman who presented with an abdominal-wall mass that resembled a tumor when assessed with magnetic resonance imaging. Twenty-six months before presenting to our office, the patient had undergone laser lipolysis and a series of treatments with a device that delivered dual-wavelength laser energy and vacuum-assisted massage. To address the patient's concerns, we removed the mass and performed abdominal dermolipectomy. No postoperative complications occurred, and the patient was highly satisfied with the aesthetic outcome. The results of histologic studies indicated that the mass was pseudocystic and fluid-filled, surrounded by a fibrous capsule, and characterized as a foreign-body granuloma. Further analysis is warranted regarding the safety of laser lipolysis without aspiration combined with a device delivering dual-wavelength laser energy and vacuum-assisted massage. 5 Risk. © 2015 The American Society for Aesthetic Plastic Surgery, Inc. Reprints and permission: journals.permissions@oup.com.
A new needle on the block: EchoTip ProCore endobronchial ultrasound needle
Dincer, H Erhan; Andrade, Rafael; Zamora, Felix; Podgaetz, Eitan
2016-01-01
Endobronchial ultrasound has become the first choice standard of care procedure to diagnose benign or malignant lesions involving mediastinum and lung parenchyma adjacent to the airways owing to its characteristics of being real-time and minimally invasive. Although the incidence of lung cancer has been decreasing, it is and will be the leading cause of cancer-related mortality in the next few decades. When compared to other cancers, lung cancer kills more females than breast and colon cancers combined and more males than colon and prostate cancers combined. The type of lung cancer has changed in recent decades and adenocarcinoma has become the most frequent cell type. Prognosis of lung cancer depends upon the cell type and the staging at the time of diagnosis. The cell type and molecular characteristics of adenocarcinoma may allow individualized targeted treatment. Other malignant conditions in the mediastinum and lung (eg, metastatic lung cancers and lymphoma) can be biopsied using endobronchial ultrasound needles. Endobronchial ultrasound needle biopsies provides mostly cytology specimens due to its small sizes of needles (22 gauge or larger) which may not give enough tissue to make a definitive diagnosis in malignant (eg, lymphoma) or benign conditions (eg, sarcoidosis). EchoTip ProCore endobronchial needle released in early 2014 provides histologic biopsy material. Larger tissue biopsies may potentially provide a higher diagnostic yield and it eliminates mediastinoscopy or other surgical interventions. Here we aim to review bronchoscopic approach in the diagnosis of mediastinal lesions with emphasis of EchoTip ProCore needles. PMID:27099535
Flat epithelial atypia on core needle biopsy, must we surgically excise?
Acott, A A; Mancino, A T
2016-12-01
Breast flat epithelial atypia (FEA) often coexists with more aggressive pathology and excision is currently recommended when diagnosed by core needle biopsy (CNB). Recent studies suggest isolated FEA has a low association with carcinoma and may warrant close surveillance. A radiology database containing 2189 breast CNB was reviewed for isolated FEA or FEA in combination with atypical pathology. 79 patients had FEA. There were 48/79 with isolated FEA and 31/79 concomitant FEA with ADH, ALH, or LCIS. 46 subsequent excisional biopsies of isolated FEA resulted: benign 38/46, ADH 5/46, LCIS 2/46, DCIS 1/46. Concomitant FEA + ADH/ALH/LCIS group resulted: benign 26/31, DCIS 3/31, DCIS and LCIS 1/31, tubular carcinoma 1/31. DCIS/invasive cancer on excision in the FEA + ADH group is 5/31 versus 1/46 for isolated FEA (p 0.0489). Findings support literature suggesting isolated FEA has a low association with carcinoma. These patients may not require surgical excision, but instead have close surveillance. Based on the higher cancer incidence in FEA combined with ADH, ALH, LCIS, or residual microcalcifications, we still recommend surgical excision. Breast flat epithelial atypia (FEA) often coexists with more aggressive pathology and surgical excision is currently recommended when diagnosed by core needle biopsy. Recent studies have suggested isolated FEA has a low association with carcinoma and these patients may warrant close surveillance. Isolated FEA has a low association with carcinoma in our series. These patients may not require surgical excision, but instead have close surveillance. Published by Elsevier Inc.
[Atypical epithelial hyperplasia of the breast: current state of knowledge and clinical practice].
Lavoué, V; Bertel, C; Tas, P; Bendavid, C; Rouquette, S; Foucher, F; Audrain, O; Bouriel, C; Levêque, J
2010-02-01
The diagnosis of atypical epithelial hyperplasia (AEH) increases with breast cancer screening. AEH is divided in three groups: atypical ductal hyperplasia, columnar cell lesions with atypia, lobular neoplasia. The management of women with AEH is not consensual because of uncertainty about their diagnosis related to the type of the biopsy sampling (core needle biopsy or surgical excision) and their controversial clinical signification between risk marker and true precursor of breast cancer. A systematic review of published studies was performed. Medline baseline interrogation was performed with the following keywords: atypical ductal hyperplasia, columnar cell lesions with atypia, lobular neoplasia, core needle biopsy, breast cancer, precursor lesion, hormonal replacement therapy. For each breast lesion, identified publications (English or French) were assessed for clinical practise in epidemiology, diagnosis and patient management. With immunohistochemistry and molecular studies, AEH seems to be precursor of breast cancer. But, epidemiological studies show low rate of breast cancer in women with AEH. AEH were still classified as risk factor of breast cancer. Because of high rate of breast cancer underestimation, surgical excision is necessary after the diagnosis of AEH at core needle biopsy. Surgical oncology rules and collaboration with radiologist are required for this surgery. A second operation was not required due to involved margins by AEH (except with pleiomorphic lobular neoplasia) because local control of breast cancer seems to be unchanged. Besides, hormonal replacement therapy for patient with AEH is not recommended because of lack of studies about this subject. Copyright 2009 Elsevier Masson SAS. All rights reserved.
Elfer, Katherine N.; Sholl, Andrew B.; Wang, Mei; Tulman, David B.; Mandava, Sree H.; Lee, Benjamin R.; Brown, J. Quincy
2016-01-01
Real-time on-site histopathology review of biopsy tissues at the point-of-procedure has great potential for significant clinical value and improved patient care. For instance, on-site review can aid in rapid screening of diagnostic biopsies to reduce false-negative results, or in quantitative assessment of biospecimen quality to increase the efficacy of downstream laboratory and histopathology analysis. However, the only currently available rapid pathology method, frozen section analysis (FSA), is too time- and labor-intensive for use in screening large quantities of biopsy tissues and is too destructive for maximum tissue conservation in multiple small needle core biopsies. In this work we demonstrate the spectrally-compatible combination of the nuclear stain DRAQ5 and the anionic counterstain eosin as a dual-component fluorescent staining analog to hematoxylin and eosin intended for use on fresh, unsectioned tissues. Combined with optical sectioning fluorescence microscopy and pseudo-coloring algorithms, DRAQ5 and eosin (“D&E”) enables very fast, non-destructive psuedohistological imaging of tissues at the point-of-acquisition with minimal tissue handling and processing. D&E was validated against H&E on a one-to-one basis on formalin-fixed paraffin-embedded and frozen section tissues of various human organs using standard epi-fluorescence microscopy, demonstrating high fidelity of the staining mechanism as an H&E analog. The method was then applied to fresh, whole 18G renal needle core biopsies and large needle core prostate biospecimen biopsies using fluorescence structured illumination optical sectioning microscopy. We demonstrate the ability to obtain high-resolution histology-like images of unsectioned, fresh tissues similar to subsequent H&E staining of the tissue. The application of D&E does not interfere with subsequent standard-of-care H&E staining and imaging, preserving the integrity of the tissue for thorough downstream analysis. These results indicate that this dual-stain pseudocoloring method could provide a real-time histology-like image at the time of acquisition and valuable objective tissue analysis for the clinician at the time of service. PMID:27788264
Lee, Minju; Min, Byung-Hoon; Lee, Hyuk; Ahn, Sangjeong; Lee, Jun Haeng; Rhee, Poong-Lyul; Kim, Jae J.; Sohn, Tae Sung; Kim, Sung; Kim, Kyoung-Mee
2015-01-01
Abstract As treatment decisions for patients with gastric subepithelial tumors (SETs) largely depend on the histopathologic diagnosis, noninvasive and effective tissue acquisition methods are definitely required for proper management of gastric SETs. Recently, a new endoscopic ultrasonography-guided fine needle biopsy (EUS-FNB) device with ProCore reverse bevel technology was developed. We aimed to elucidate the feasibility and diagnostic yield of EUS-FNB with this new core biopsy needle device in patients with gastric SETs. A prospectively maintained database was retrospectively reviewed to identify consecutive patients who underwent EUS-FNB with a 22-gauge ProCore needle for gastric SETs 2 cm or larger. The main outcome measurement was the diagnostic yield of EUS-FNB. Procedure results were categorized into diagnostic, suggestive, or nondiagnostic. Of the 43 patients, needle punctures were successful in all cases irrespective of tumor location. EUS-FNB procedure results were diagnostic in 86.0%, suggestive in 4.7%, and nondiagnostic in 9.3% of cases, respectively. The diagnostic yield was the highest in fundus (100.0%), followed by body (89.5%), cardia (83.3%), and antrum (50.0%). All 18 patients with cardiac SET were finally diagnosed to have leiomyoma, and 16 patients with diagnostic or suggestive results avoided surgery. A heterogeneous echo pattern on EUS was found in 33.3% of cases with nondiagnostic or suggestive results and in 5.4% with diagnostic results. In multivariate analysis, no independent predictor of unsuccessful EUS-FNB with nondiagnostic or suggestive results was identified. Agreement between EUS-FNB and surgical pathology was 100% with respect to the diagnosis of gastrointestinal stromal tumor. However, there was a significant discrepancy in mitotic counts observed between the EUS-FNB and surgical specimens in patients with gastrointestinal stromal tumor. There were no significant procedure-related adverse events during and after the procedures. EUS-FNB with a 22G ProCore needle is a technically feasible, safe, and effective procedure for pathologic diagnosis of gastric SETs. This procedure can help refine surgical indications and facilitate a proper treatment decisions for gastric SETs, especially in the cardia. PMID:26448008
Hansen, Nienke; Patruno, Giulio; Wadhwa, Karan; Gaziev, Gabriele; Miano, Roberto; Barrett, Tristan; Gnanapragasam, Vincent; Doble, Andrew; Warren, Anne; Bratt, Ola; Kastner, Christof
2016-08-01
Prostate biopsy supported by transperineal image fusion has recently been developed as a new method to the improve accuracy of prostate cancer detection. To describe the Ginsburg protocol for transperineal prostate biopsy supported by multiparametric magnetic resonance imaging (mpMRI) and transrectal ultrasound (TRUS) image fusion, provide learning points for its application, and report biopsy results. The article is supplemented by a Surgery in Motion video. This single-centre retrospective outcome study included 534 patients from March 2012 to October 2015. A total of 107 had no previous prostate biopsy, 295 had benign TRUS-guided biopsies, and 159 were on active surveillance for low-risk cancer. A Likert scale reported mpMRI for suspicion of cancer from 1 (no suspicion) to 5 (cancer highly likely). Transperineal biopsies were obtained under general anaesthesia using BiopSee fusion software (Medcom, Darmstadt, Germany). All patients had systematic biopsies, two cores from each of 12 anatomic sectors. Likert 3-5 lesions were targeted with a further two cores per lesion. Any cancer and Gleason score 7-10 cancer on biopsy were noted. Descriptive statistics and positive predictive values (PPVs) and negative predictive values (NPVs) were calculated. The detection rate of Gleason score 7-10 cancer was similar across clinical groups. Likert scale 3-5 MRI lesions were reported in 378 (71%) of the patients. Cancer was detected in 249 (66%) and Gleason score 7-10 cancer was noted in 157 (42%) of these patients. PPV for detecting 7-10 cancer was 0.15 for Likert score 3, 0.43 for score 4, and 0.63 for score 5. NPV of Likert 1-2 findings was 0.87 for Gleason score 7-10 and 0.97 for Gleason score ≥4+3=7 cancer. Limitations include lack of data on complications. Transperineal prostate biopsy supported by MRI/TRUS image fusion using the Ginsburg protocol yielded high detection rates of Gleason score 7-10 cancer. Because the NPV for excluding Gleason score 7-10 cancer was very high, prostate biopsies may not be needed for all men with elevated prostate-specific antigen values and nonsuspicious mpMRI. We present our technique to sample (biopsy) the prostate by the transperineal route (the area between the scrotum and the anus) to detect prostate cancer using a fusion of magnetic resonance and ultrasound images to guide the sampling. Copyright © 2016 European Association of Urology. All rights reserved.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Oppenheimer, Jason D., E-mail: j-oppenheimer@md.northwestern.edu; Kasuganti, Deepa; Nayar, Ritu
2010-08-15
Results of thyroid biopsy determine whether thyroid nodule resection is appropriate and the extent of thyroid surgery. At our institution we use 20/22-gauge core biopsy (CBx) in conjunction with fine-needle aspiration (FNA) to decrease the number of passes and improve adequacy. Occasionally, both ultrasound (US)-guided FNA and CBx yield unsatisfactory specimens. To justify clinical recommendations for these unsatisfactory thyroid biopsies, we compare rates of malignancy at surgical resection for unsatisfactory biopsy results against definitive biopsy results. We retrospectively reviewed a database of 1979 patients who had a total of 2677 FNA and 663 CBx performed by experienced interventional radiologists undermore » US guidance from 2003 to 2006 at a tertiary-care academic center. In 451 patients who had surgery following biopsy, Fisher's exact test was used to compare surgical malignancy rates between unsatisfactory and malignant biopsy cohorts as well as between unsatisfactory and benign biopsy cohorts. We defined statistical significance at P = 0.05. We reported an overall unsatisfactory thyroid biopsy rate of 3.7% (100/2677). A statistically significant higher rate of surgically proven malignancies was found in malignant biopsy patients compared to unsatisfactory biopsy patients (P = 0.0001). The incidence of surgically proven malignancy in unsatisfactory biopsy patients was not significantly different from that in benign biopsy patients (P = 0.8625). In conclusion, an extremely low incidence of malignancy was associated with both benign and unsatisfactory thyroid biopsy results. The difference in incidence between these two groups was not statistically significant. Therefore, patients with unsatisfactory biopsy specimens can be reassured and counseled accordingly.« less
The liquid biopsy in lung cancer.
Ansari, Junaid; Yun, Jungmi W; Kompelli, Anvesh R; Moufarrej, Youmna E; Alexander, Jonathan S; Herrera, Guillermo A; Shackelford, Rodney E
2016-11-01
The incidence of lung cancer has significantly increased over the last century, largely due to smoking, and remains the most common cause of cancer deaths worldwide. This is often due to lung cancer first presenting at late stages and a lack of curative therapeutic options at these later stages. Delayed diagnoses, inadequate tumor sampling, and lung cancer misdiagnoses are also not uncommon due to the limitations of the tissue biopsy. Our better understanding of the tumor microenvironment and the systemic actions of tumors, combined with the recent advent of the liquid biopsy, may allow molecular diagnostics to be done on circulating tumor markers, particularly circulating tumor DNA. Multiple liquid biopsy molecular methods are presently being examined to determine their efficacy as surrogates to the tumor tissue biopsy. This review will focus on new liquid biopsy technologies and how they may assist in lung cancer detection, diagnosis, and treatment.
Liu, Zhenbin; Zhang, Min; Wang, Yuchuan
2016-06-01
Old stalks of Asparagus officinalis, which account for one third of the total length of each spear, are always discarded as waste. To make full use of the resource, a kind of restructured Asparagus officinalis chip was made. The effects of pulse-spouted microwave-assisted vacuum drying (PSMVD), microwave-assisted vacuum drying (MVD) and vacuum drying (VD) on texture, color and other quality parameters of restructured chips were then studied to obtain high-quality dried chips. Results indicated that the drying time was significantly affected by drying methods, and PSMVD had much better drying uniformity than MVD. The expansion ratio and crispness of chips increased with increasing microwave power and vacuum degree. The browning reaction of samples in VD was more serious, which was confirmed by the results of color test and electronic nose. The PSMVD drying method showed much better drying uniformity than MVD. The dried chips obtained by PSMVD showed optimal quality and were more readily accepted by consumers. © 2015 Society of Chemical Industry. © 2015 Society of Chemical Industry.
U.S. Army Oxygen Generation System Development
2010-04-01
engines), scroll pumps , and rotary vane pumps . The turbo compressor is a design that trades the size and weight of the low speed compressors for a...is exposed to water. A guard bed of silica gel is used to protect the bed from moisture. A variation of the process ends the cycle using a vacuum ...phase. With the vacuum assist the total change of pressure is the same as the PSA process, but the maximum pressure is lower. Not only does the vacuum
FNAC Versus Core Needle Biopsy: A Comparative Study in Evaluation of Palpable Breast Lump
Saha, Abhijit; Mukhopadhyay, Madhumita; Sarkar, Koushik; Saha, Ashis Kumar; Sarkar, Diptendra KR
2016-01-01
Introduction Breast carcinoma is the most common malignant tumour and the leading cause of carcinoma death in women in world. The main purpose of FNAC or CNB of breast lumps is to confirm cancer preoperatively and to avoid unnecessary surgery in specific benign conditions. Aims and Objective The objective of the study was to compare between Fine Needle Aspiration Cytology (FNAC) and Core Needle Biopsy (CNB) in the diagnosis of breast carcinoma with final histological diagnosis from excision specimen as it is gold standard. Materials and Methods A prospective study was done on 50 cases. Patients undergoing all three procedures (Fine Needle Aspiration Cytology and Core Needle Biopsy done at Department of Pathology; subsequent excision surgeries done at Department of General Surgery) were selected. May Grunwald Giemsa (MGG) and Papaniculou (PAP) staining were performed on cytology smears. Haematoxylin and Eosin (H&E) staining was done on both the CNB and tissue specimens obtained from subsequent excision surgeries to see the histological features. Results FNAC showed sensitivity, specificity, positive predictive value, negative predictive value, and diagnostic accuracy were 69%, 100%, 100%, 38.1%, and 74% respectively in diagnosing carcinoma. CNB had sensitivity, specificity, positive predictive value, negative predictive value, and diagnostic accuracy of 88.3%, 100%, 100%, 53.3% and 86%. Both FNAC and CNB showed statistically significant correlation with confirmatory HPE of excision specimen (p-value <0.05) in the diagnosis of breast carcinoma. Conclusion Fine needle aspiration cytology (FNAC) is a rapid, less complicated, economical, reliable and relevant method for the preoperative pathological diagnosis of breast carcinoma in a developing nation like ours. If the initial FNAC is inadequate, core needle biopsy (CNB) can be a useful second line method of pathological diagnosis in order to minimize the chance of missed diagnosis of breast cancer. PMID:27042469
Predicting the risk of patients with biopsy Gleason score 6 to harbor a higher grade cancer.
Gofrit, Ofer N; Zorn, Kevin C; Taxy, Jerome B; Lin, Shang; Zagaja, Gregory P; Steinberg, Gary D; Shalhav, Arieh L
2007-11-01
Prostate cancer Gleason score 3 + 3 = 6 is currently the most common score assigned on prostatic biopsies. We analyzed the clinical variables that predict the likelihood of a patient with biopsy Gleason score 6 to harbor a higher grade tumor. The study population consisted of 448 patients with a mean age of 59.1 years who underwent radical prostatectomy between February 2003 to October 2006 for Gleason score 6 adenocarcinoma. The effect of preoperative variables on the probability of a Gleason score upgrade on final pathological evaluation was evaluated using logistic regression, and classification and regression tree analysis. Gleason score upgrade was found in 91 of 448 patients (20.3%). Logistic regression showed that only serum prostate specific antigen and the greatest percent of cancer in a core were significantly associated with a score upgrade (p = 0.0014 and 0.023, respectively). Classification and regression tree analysis showed that the risk of a Gleason score upgrade was 62% when serum prostate specific antigen was higher than 12 ng/ml and 18% when serum prostate specific antigen was 12 ng/ml or less. In patients with serum prostate specific antigen lower than 12 ng/ml the risk of a score upgrade could be dichotomized at a greatest percent of cancer in a core of 5%. The risk was 22.6% and 10.5% when the greatest percent of cancer in a core was higher than 5% and 5% or lower, respectively. The probability of patients with a prostate biopsy Gleason score of 6 to conceal a Gleason score of 7 or higher can be predicted using serum prostate specific antigen and the greatest percent of cancer in a core. With these parameters it is possible to predict upgrade rates as high as 62% and as low as 10.5%.
Antonini, Filippo; Fuccio, Lorenzo; Giorgini, Sara; Fabbri, Carlo; Frazzoni, Leonardo; Scarpelli, Marina; Macarri, Giampiero
2017-08-01
While the presence of biliary stent significantly decreases the accuracy of endoscopic ultrasound (EUS) for pancreatic head cancer staging, its impact on the EUS-guided sampling accuracy is still debated. Furthermore, data on EUS-fine needle biopsy (EUS-FNB) using core biopsy needles in patients with pancreatic mass and biliary stent are lacking. The aim of this study was to evaluate the influence of biliary stent on the adequacy and accuracy of EUS-FNB in patients with pancreatic head mass. All patients who underwent EUS-guided sampling with core needles of solid pancreatic head masses causing obstructive jaundice were retrospectively identified in a single tertiary referral center. Adequacy, defined as the rate of cases in which a tissue specimen for proper examination was achieved, with and without biliary stent, was the primary outcome measure. The diagnostic accuracy and complication rate were the secondary outcome measures. A total of 130 patients with pancreatic head mass causing biliary obstruction were included in the study: 74 cases of them were sampled without stent and 56 cases with plastic stent in situ. The adequacy was 96.4% in the stent group and 90.5% in the group without stent (p=0.190). No significant differences were observed for sensitivity (88.9% vs. 85.9%), specificity (100% for both groups), and accuracy (89.3% vs. 86.5%) between those with and without stent, respectively. The accuracy was not influenced by the timing of stenting (<48h or ≥48h before EUS). No EUS-FNB related complications were recorded. The presence of biliary stent does not influence the tissue sampling adequacy, the diagnostic accuracy and the complication rate of EUS-FNB of pancreatic head masses performed with core biopsy needles. Copyright © 2017 Editrice Gastroenterologica Italiana S.r.l. Published by Elsevier Ltd. All rights reserved.
Transjugular Renal Biopsy: Our Experience and Technical Considerations
DOE Office of Scientific and Technical Information (OSTI.GOV)
See, Teik Choon, E-mail: teikchoon.see@addenbrookes.nhs.u; Thompson, Barbara C.; Howie, Alexander J.
2008-09-15
The purpose of this study was to describe the indications for and technique of transjugular renal biopsy (TJRB) and evaluate the efficacy and complications of this method. We performed a retrospective review of 59 patients who underwent TJRB using the Quick-core needle biopsy system (Cook, Letchworth, UK) over a 4-year period. The indications for obtaining renal biopsy included acute renal failure, chronic renal failure, nephrotic syndrome, and proteinuria with or without other associated disease. Indications for the transjugular approach included coagulopathy, biopsy of a solitary kidney or essentially single functioning kidney, simultaneous renal and hepatic biopsy, morbid obesity, and failedmore » percutaneous biopsy. All but four cases were performed via the right internal jugular vein. The right, left, or both renal veins were cannulated in 41, 14, and 4 cases, respectively. Combined liver and renal biopsies were obtained in seven cases. Diagnostic biopsy specimens were obtained in 56 of 59 patients (95%). The number and size of tissue cores ranged from 1 to 9 mm and from 1 to 20 mm, respectively. The mean numbers of glomeruli per procedure on light microscopy and electron microscopy were 10.3 and 2.6, respectively. Specimens for immunohistology were acquired in 49 cases, of which 40 were adequate. Of the 56 successful TJRB procedures, 34 (61%) were associated with isolated capsular perforation (19), contained subcapsular leak (10), isolated collecting system puncture (1), and concurrent collecting system and capsular perforation (4). There was a significant increase in capsular perforation with six or more needle passes, although no significant correlation was seen between number of needle passes and complication. Six patients had minor complications defined as hematuria or loin pain. Seven patients developed major complications, of whom five received blood transfusion alone. Two required intervention: in one an arteriocalyceal fistula was embolized and the patient was temporarily dialyzed; the remaining patient required ureteric stenting. In conclusion, TJRB provides an adequate yield for diagnosis. Complication rates are relatively high, but patients are also at high risk from the conventional percutaneous approach. Patient selection and optimization are critical to avoid major complications.« less
Morelli, Girolamo; Pagni, Riccardo; Mariani, Chiara; Minervini, Riccardo; Morelli, Andrea; Gori, Francesco; Ferdeghini, Ezio Maria; Paterni, Marco; Mauro, Eva; Guidi, Elisa; Armillotta, Nicola; Canale, Domenico; Vitti, Paolo; Caramella, Davide; Minervini, Andrea
2011-06-01
We evaluated the ability of the phosphodiesterase-5 inhibitor vardenafil to increase prostate microcirculation during power Doppler ultrasound. We also evaluated the results of contrast and vardenafil enhanced targeted biopsies compared to those of standard 12-core random biopsies to detect cancer. Between May 2008 and January 2010, 150 consecutive patients with prostate specific antigen more than 4 ng/ml at first diagnosis with negative digital rectal examination and transrectal ultrasound, and no clinical history of prostatitis underwent contrast enhanced power Doppler ultrasound (bolus injection of 2.4 ml SonoVue® contrast agent), followed by vardenafil enhanced power Doppler ultrasound (1 hour after oral administration of vardenafil 20 mg). All patients underwent standard 12-core transrectal ultrasound guided random prostate biopsy plus 1 further sampling from each suspected hypervascular lesion detected by contrast and vardenafil enhanced power Doppler ultrasound. Prostate cancer was detected in 44 patients (29.3%). Contrast and vardenafil enhanced power Doppler ultrasound detected suspicious, contrast enhanced and vardenafil enhanced areas in 112 (74.6%) and 110 patients (73.3%), and was diagnostic for cancer in 32 (28.5%) and 42 (38%), respectively. Analysis of standard technique, and contrast and vardenafil enhanced power Doppler ultrasound findings by biopsy core showed significantly higher detection using vardenafil vs contrast enhanced power Doppler ultrasound and standard technique (41.2% vs 22.7% and 8.1%, p <0.005 and <0.001, respectively). The detection rate of standard plus contrast or vardenafil enhanced power Doppler ultrasound was 10% and 11.7% (p not significant). Vardenafil enhanced power Doppler ultrasound enables excellent visualization of the microvasculature associated with cancer and can improve the detection rate compared to contrast enhanced power Doppler ultrasound and the random technique. Copyright © 2011 American Urological Association Education and Research, Inc. Published by Elsevier Inc. All rights reserved.
Design by Dragging: An Interface for Creative Forward and Inverse Design with Simulation Ensembles
Coffey, Dane; Lin, Chi-Lun; Erdman, Arthur G.; Keefe, Daniel F.
2014-01-01
We present an interface for exploring large design spaces as encountered in simulation-based engineering, design of visual effects, and other tasks that require tuning parameters of computationally-intensive simulations and visually evaluating results. The goal is to enable a style of design with simulations that feels as-direct-as-possible so users can concentrate on creative design tasks. The approach integrates forward design via direct manipulation of simulation inputs (e.g., geometric properties, applied forces) in the same visual space with inverse design via “tugging” and reshaping simulation outputs (e.g., scalar fields from finite element analysis (FEA) or computational fluid dynamics (CFD)). The interface includes algorithms for interpreting the intent of users’ drag operations relative to parameterized models, morphing arbitrary scalar fields output from FEA and CFD simulations, and in-place interactive ensemble visualization. The inverse design strategy can be extended to use multi-touch input in combination with an as-rigid-as-possible shape manipulation to support rich visual queries. The potential of this new design approach is confirmed via two applications: medical device engineering of a vacuum-assisted biopsy device and visual effects design using a physically based flame simulation. PMID:24051845
Ahmed, Zeeshan; Patel, Pinakin; Singh, Suresh; Sharma, Raj Govind; Somani, Pankaj; Gouri, Abdul Rauf; Singh, Shiv
2016-01-01
Subcutaneous emphysema is a common complication of tube thoracostomy. Though self-limiting, it should be treated when it causes palpebral closure, dyspnea, dysphagia or undue disfigurement resulting in anxiety and distress to the patient. A 72year old man who was a known case of COPD on bronchodilators developed a large pneumothorax and respiratory distress after a CT guided transthoracic lung biopsy done for a lung opacity (approx. 3×3cm) at the right hilar region on Chest X-ray. Within 24h of an urgent tube thoracostomy, patient developed intractable subcutaneous emphysema with closure of palpebral fissure and dyspnea unresponsive to increasing suction on chest tube. A subcutaneous fenestrated drain was placed mid-way between the nipple and clavicle in the mid-clavicular line bilaterally. Continuous negative suction (-150mmHg) resulted in immediate, sustained relief and complete resolution within 5days. Extensive and debilitating SE (subcutaneous emphysema) has to be treated promptly to relieve patient discomfort, dysphagia or imminent respiratory compromise. A variety of treatment have been tried including infraclavicular blow-hole incisions, subcutaneous drains +/- negative pressure suction, fenestrated angiocatheters, Vacuum assisted dressings and increasing suction on a pre-existing chest tube. We describe a high negative pressure subcutaneous suction drain which provides immediate and sustained relief in debilitating SE. Debilitating subcutaneous emphysema which causes distress, anxiety, palpebral closure, dyspnoea or dysphagia requires intervention. High negative pressure subcutaneous suction drain provides immediate and sustained relief in extensive and debilitating SE. Copyright © 2016 The Authors. Published by Elsevier Ltd.. All rights reserved.
Development of a 3D ultrasound-guided prostate biopsy system
NASA Astrophysics Data System (ADS)
Cool, Derek; Sherebrin, Shi; Izawa, Jonathan; Fenster, Aaron
2007-03-01
Biopsy of the prostate using ultrasound guidance is the clinical gold standard for diagnosis of prostate adenocarinoma. However, because early stage tumors are rarely visible under US, the procedure carries high false-negative rates and often patients require multiple biopsies before cancer is detected. To improve cancer detection, it is imperative that throughout the biopsy procedure, physicians know where they are within the prostate and where they have sampled during prior biopsies. The current biopsy procedure is limited to using only 2D ultrasound images to find and record target biopsy core sample sites. This information leaves ambiguity as the physician tries to interpret the 2D information and apply it to their 3D workspace. We have developed a 3D ultrasound-guided prostate biopsy system that provides 3D intra-biopsy information to physicians for needle guidance and biopsy location recording. The system is designed to conform to the workflow of the current prostate biopsy procedure, making it easier for clinical integration. In this paper, we describe the system design and validate its accuracy by performing an in vitro biopsy procedure on US/CT multi-modal patient-specific prostate phantoms. A clinical sextant biopsy was performed by a urologist on the phantoms and the 3D models of the prostates were generated with volume errors less than 4% and mean boundary errors of less than 1 mm. Using the 3D biopsy system, needles were guided to within 1.36 +/- 0.83 mm of 3D targets and the position of the biopsy sites were accurately localized to 1.06 +/- 0.89 mm for the two prostates.
Mariotti, Guilherme C; Costa, Daniel N; Pedrosa, Ivan; Falsarella, Priscila M; Martins, Tatiana; Roehrborn, Claus G; Rofsky, Neil M; Xi, Yin; M Andrade, Thais C; Queiroz, Marcos R; Lotan, Yair; Garcia, Rodrigo G; Lemos, Gustavo C; Baroni, Ronaldo H
2016-09-01
To determine the incremental diagnostic value of targeted biopsies added to an extended sextant biopsy scheme on a per-patient, risk-stratified basis in 2 academic centers using different multiparametric magnetic resonance imaging (MRI) protocols, a large group of radiologists, multiple biopsy systems, and different biopsy operators. All patients with suspected prostate cancer (PCa) who underwent multiparametric MRI of the prostate in 2 academic centers between February 2013 and January 2015 followed by systematic and targeted MRI-transrectal ultrasound fusion biopsy were reviewed. Risk-stratified detection rate using systematic biopsies was compared with targeted biopsies on a per-patient basis. The McNemar test was used to compare diagnostic performance of the 2 approaches. A total of 389 men met eligibility criteria. PCa was diagnosed in 47% (182/389), 52%(202/389), and 60%(235/389) of patients using the targeted, systematic, and combined (targeted plus systematic) approach, respectively. Compared with systematic biopsy, targeted biopsy diagnosed 11% (37 vs. 26) more intermediate-to-high risk (P<0.0001) and 16% (10 vs. 16) fewer low-risk tumors (P<0.0001). These results were replicated when data from each center, biopsy-naïve patients, and men with previous negative biopsies were analyzed separately. Targeted MRI-transrectal ultrasound fusion biopsy consistently improved the detection of clinically significant PCa in a large patient cohort with diverse equipment, protocols, radiologists, and biopsy operators as can be encountered in clinical practice. Copyright © 2016 Elsevier Inc. All rights reserved.
Xiao, Xiaohua; Song, Wei; Wang, Jiayue; Li, Gongke
2012-01-27
In this study, low temperature vacuum microwave-assisted extraction, which simultaneous performed microwave-assisted extraction (MAE) in low temperature and in vacuo environment, was proposed. The influencing parameters including solid/liquid ratio, extraction temperature, extraction time, degree of vacuum and microwave power were discussed. The predominance of low temperature vacuum microwave-assisted extraction was investigated by comparing the extraction yields of vitamin C, β-carotene, aloin A and astaxanthin in different foods with that in MAE and solvent extraction, and 5.2-243% increments were obtained. On the other hand, the chemical kinetics of vitamin C and aloin A, which composed two different steps including the extraction step of analyte transferred from matrix into solvent and the decomposition step of analyte degraded in the extraction solvent, were proposed. All of the decomposition rates (K(2)) for the selected analyte in low temperature, in vacuo and in nitrogen atmosphere decreased significantly comparing with that in conventional MAE, which are in agreement with that obtained from experiments. Consequently, the present method was successfully applied to extract labile compound from different food samples. These results showed that low temperature and/or in vacuo environment in microwave-assisted extraction system was especially important to prevent the degradation of labile components and have good potential on the extraction of labile compound in foods, pharmaceutical and natural products. Copyright © 2011 Elsevier B.V. All rights reserved.
Perlman, Katherine L; Shelby, Rebecca A; Wren, Anava A; Kelleher, Sarah A; Dorfman, Caroline S; O'Connor, Erin; Kim, Connie; Johnson, Karen S; Soo, Mary Scott
2017-12-01
Positive and negative mood are independent psychological responses to stressful events. Negative mood negatively impacts well-being and co-occurring positive mood leads to improved adjustment. Women undergoing core needle breast biopsies (CNB) experience distress during CNB and awaiting results; however, influences of mood are not well known. This longitudinal study examines psychosocial and biopsy- and spirituality-related factors associated with mood in patients day of CNB and one week after receiving results. Ninety women undergoing CNB completed questionnaires on psychosocial factors (chronic stress, social support), biopsy experiences (pain, radiologist communication), and spirituality (peace, meaning, faith) day of CNB. Measures of positive and negative mood were completed day of CNB and one week after receiving results (benign n = 50; abnormal n = 25). Multiple linear regression analyses were conducted. Greater positive mood correlated with greater peace (β = .25, p = .02) day of CNB. Lower negative mood correlated with greater peace (β = -.29, p = .004) and there was a trend for a relationship with less pain during CNB (β = .19, p = .07). For patients with benign results, day of CNB positive mood predicted positive mood post-results (β = .31, p = .03) and only chronic stress predicted negative mood (β = .33, p = .03). For women with abnormal results, greater meaning day of CNB predicted lower negative mood post-results (β = -.45, p = .03). Meaning and peace may be important for women undergoing CNB and receiving abnormal results.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Vibhakorn, Shusang; Cholongitas, Evangelos; Kalambokis, George
2009-05-15
Recently, it has been shown that transjugular liver biopsy (TJLB) with three passes gives comparable specimens to percutaneous liver biopsy (PLB). The aim of this study was to evaluate the adequacy of TJLB using four passes in a consecutive series of patients, and whether using a supportive cassette can prevent fragmentation. One hundred consecutive TJLBs in 92 patients (48 transplanted), always using four passes (19-G Tru-Cut), were compared to three-pass TJLBs. The four-pass TJLB specimens were randomized at a 1:1 ratio of liver cores placed in a cassette versus not. The four-pass TJLBs, compared to three-pass TJLBs, resulted in bettermore » specimens for length ({>=}25 mm: 50% vs. 35%; p = 0.026) and number of complete portal tracts (CPTs) ({>=}11: 40% vs. 26%; p = 0.027), without a higher complication rate. The four-pass TJLB with {>=}11 CPTs had a median length of 27 mm, and 57% of them longer than 28 mm contained {>=}11 CPTs. Putting the liver biopsy cores into a cassette did not improve the fragmentation rate or adequacy of the specimen (length and number of CPTs) of TJLB. We conclude that at least four passes with TJLB should be performed when liver specimens are needed for grading and staging. Using a supportive cassette did not reduce fragmentation.« less
NASA Technical Reports Server (NTRS)
Chuang, Kathy C.; Criss, Jim M.; Mintz, Eric A.
2011-01-01
RTM370 imide resin based on 2,3,3 ,4 -biphenyl dianhydride ( a-BPDA), 3,4 -oxydianinline (3,4 -ODA) with 4-phenylethynylphthalic (PEPA) endcap has shown to exhibit high Tg (370 C) and low melt viscosity (10-30 poise) at 280 C with a pot-life of 1-2 h. Previously, RTM370 resin has been fabricated into composites with T650-35 carbon fabrics by resin transfer molding (RTM) successfully. RTM370 composites exhibit excellent mechanical properties up to 327 C (620 F), and outstanding property retention after aging at 288 C (550 F) for 1000 hrs. In this presentation, RTM 370 composites will be fabricated by vacuum assisted resins transfer molding (VARTM), using vacuum bags without mold. The mechanical properties of RTM370 composites fabricated by VARTM will be compared to those of RTM370 made by RTM.
NASA Technical Reports Server (NTRS)
Chuang, Kathy C.; Criss, James M.; Mintz, Eric A.; Shonkwiler, Brian; McCorkle, Linda S.
2011-01-01
RTM370 imide resin based on 2,3,3?,4?-biphenyl dianhydride (a-BPDA), 3,4'-oxydianinline (3,4'-ODA) with the 4-phenylethynylphthalic (PEPA) endcap has been shown to exhibit a high cured T(sub g) (370 C) and low melt viscosity (10-30 poise) at 280 C with a pot-life of 1-2 h. Previously, RTM370 resin has been successfully fabricated into composites reinforced with T650-35 carbon fabrics by resin transfer molding (RTM). RTM370 composites exhibit excellent mechanical properties up to 327?C (620?F), and outstanding property retention after aging at 288?C (550?F) for 1000 h. In this work, RTM370 composites were fabricated by vacuum assisted resin transfer molding (VARTM), using vacuum bags on a steel plate. The mechanical properties of RTM370 composites fabricated by VARTM are compared to those prepared by RTM.
Ionization-Assisted Getter Pumping for Ultra-Stable Trapped Ion Frequency Standards
NASA Technical Reports Server (NTRS)
Tjoelker, Robert L.; Burt, Eric A.
2010-01-01
A method eliminates (or recovers from) residual methane buildup in getter-pumped atomic frequency standard systems by applying ionizing assistance. Ultra-high stability trapped ion frequency standards for applications requiring very high reliability, and/or low power and mass (both for ground-based and space-based platforms) benefit from using sealed vacuum systems. These systems require careful material selection and system processing (cleaning and high-temperature bake-out). Even under the most careful preparation, residual hydrogen outgassing from vacuum chamber walls typically limits the base pressure. Non-evaporable getter pumps (NEGs) provide a convenient pumping option for sealed systems because of low mass and volume, and no power once activated. An ion gauge in conjunction with a NEG can be used to provide a low mass, low-power method for avoiding the deleterious effects of methane buildup in high-performance frequency standard vacuum systems.
Method and apparatus for the formation of a spheromak plasma
Yamada, Masaaki; Furth, Harold P.; Stix, Thomas H.; Todd, Alan M. M.
1982-01-01
A method and apparatus for forming a detached, compact toroidally shaped spheromak plasma by an inductive mechanism. A generally spheroidal vacuum vessel (1) houses a toroidally shaped flux ring or core (2) which contains poloidal and toroidal field generating coils. A plasma discharge occurs with the pulsing of the toroidal field coil, and the plasma is caused to expand away from the core (2) and toward the center of the vacuum vessel (1). When the plasma is in an expanded state, a portion of it is pinched off in order to form a separate, detached spheromak plasma configuration. The detached plasma is supported by a magnetic field generated by externally arranged equilibrium field coils (5).
Ibrahimi, Omar A; Kilmer, Suzanne L
2012-06-01
The long-pulsed diode (800-810-nm) laser is one of the most commonly used and effective lasers for hair removal. Limitations of currently available devices include a small treatment spot size, treatment-associated pain, and the need for skin cooling. To evaluate the long-term hair reduction capabilities of a long-pulsed diode laser with a large spot size and vacuum assisted suction. Thirty-five subjects were enrolled in a prospective, self-controlled, single-center study of axillary hair removal. The study consisted of three treatments using a long-pulsed diode laser with a large spot size and vacuum-assisted suction at 4- to 6-week intervals with follow-up visits 6 and 15 months after the last treatment. Hair clearance was quantified using macro hair-count photographs taken at baseline and at 6- and 15-month follow-up visits. Changes in hair thickness and color, levels of treatment-associated pain, and adverse events were additional study endpoints. There was statistically significant hair clearance at the 6 (54%) and 15-month (42%) follow-up visits. Remaining hairs were thinner and lighter at the 15-month follow-up visit, and the majority of subjects reported feeling up to mild to moderate pain during treatment without the use of pretreatment anesthesia or skin cooling. A long-pulsed diode laser with a large spot size and vacuum-assisted suction is safe and effective for long-term hair removal. This is the largest prospective study to evaluate long-term hair removal and the first to quantify decreases in hair thickness and darkness with treatment. © 2012 by the American Society for Dermatologic Surgery, Inc. Published by Wiley Periodicals, Inc.
Zorn, Kevin C; Capitanio, Umberto; Jeldres, Claudio; Arjane, Philippe; Perrotte, Paul; Shariat, Shahrokh F; Lee, David I; Shalhav, Arieh L; Zagaja, Gregory P; Shikanov, Sergey A; Gofrit, Ofer N; Thong, Alan E; Albala, David M; Sun, Leon; Karakiewicz, Pierre I
2009-04-01
The Partin tables represent one of the most widely used prostate cancer staging tools for seminal vesicle invasion (SVI) prediction. Recently, Gallina et al. reported a novel staging tool for the prediction of SVI that further incorporated the use of the percentage of positive biopsy cores. We performed an external validation of the Gallina et al. nomogram and the 2007 Partin tables in a large, multi-institutional North American cohort of men treated with robotic-assisted radical prostatectomy. Clinical and pathologic data were prospectively gathered from 2,606 patients treated with robotic-assisted radical prostatectomy at one of four North American robotic referral centers between 2002 and 2007. Discrimination was quantified with the area under the receiver operating characteristics curve. The calibration compared the predicted and observed SVI rates throughout the entire range of predictions. At robotic-assisted radical prostatectomy, SVI was recorded in 4.2% of patients. The discriminant properties of the Gallina et al. nomogram resulted in 81% accuracy compared with 78% for the 2007 Partin tables. The Gallina et al. nomogram overestimated the true rate of SVI. Conversely, the Partin tables underestimated the true rate of SVI. The Gallina et al. nomogram offers greater accuracy (81%) than the 2007 Partin tables (78%). However, both tools are associated with calibration limitations that need to be acknowledged and considered before their implementation into clinical practice.
Granulomatous Lobular Mastitis.
Mahlab-Guri, Keren; Asher, Ilan; Allweis, Tanir; Diment, Judith; Sthoeger, Zev M; Mavor, Eliezer
2015-08-01
Granulomatous lobular mastitis (GLM) is a rare disorder that can clinically mimic breast carcinoma. The recommendation for diagnosis and treatment of GLM has not yet been established. To assess a series of GLM patients, including their clinical presentation, diagnosis, treatment and outcome. We retrospectively analyzed the clinical data and treatment of 17 female patients with biopsy-proven GLM. Breast tissue was obtained by a core needle biopsy (15 patients) or open biopsy (2 patients). Images were reviewed by an experienced radiologist. The mean age of the patients at diagnosis was 44.6 ± 12.6 years. Five patients (29%) presented with bilateral disease, and seven (41%) presented with a mass, suggesting the initial diagnosis of breast carcinoma. Treatment comprised observation alone (23%), antibiotics (58.8%) and/or corticosteroids (with or without methotrexate) (35%). At the end of the study 70.6% of the patients demonstrated complete remission. None of the patients developed any systemic (granulomatous) disease or breast carcinoma during the follow-up period (4.7 ± 3.8 years). Core needle biopsy is mandatory for the diagnosis of GLM and the exclusion of breast carcinoma. The recommended treatment modalities are observation alone or corticosteroids; surgery should be avoided. GLM is a benign disease with a high rate of resolution and complete remission.
Does imprint cytology improve the accuracy of transrectal prostate needle biopsy?
Sayar, Hamide; Bulut, Burak Besir; Bahar, Abdulkadir Yasir; Bahar, Mustafa Remzi; Seringec, Nurten; Resim, Sefa; Çıralık, Harun
2015-02-01
To evaluate the accuracy of imprint cytology of core needle biopsy specimens in the diagnosis of prostate cancer. Between December 24, 2011 and May 9, 2013, patients with an abnormal DRE and/or serum PSA level of >2.5 ng/mL underwent transrectal prostate needle biopsy. Samples with positive imprint cytology but negative initial histologic exam underwent repeat sectioning and histological examination. 1,262 transrectal prostate needle biopsy specimens were evaluated from 100 patients. Malignant imprint cytology was found in 236 specimens (18.7%), 197 (15.6%) of which were confirmed by histologic examination, giving an initial 3.1% (n = 39) rate of discrepant results by imprint cytology. Upon repeat sectioning and histologic examination of these 39 biopsy samples, 14 (1.1% of the original specimens) were then diagnosed as malignant, 3 (0.2%) as atypical small acinar proliferation (ASAP), and 5 (0.4%) as high-grade prostatic intraepithelial neoplasia (HGPIN). Overall, 964 (76.4%) specimens were negative for malignancy by imprint cytology. Seven (0.6%) specimens were benign by cytology but malignant cells were found on histological evaluation. On imprint cytology examination, nonmalignant but abnormal findings were seen in 62 specimens (4.9%). These were all due to benign processes. After reexamination, the accuracy, sensitivity, specificity, positive predictive value, negative predictive value, false-positive rate, false-negative rate of imprint preparations were 98.1, 96.9, 98.4, 92.8, 99.3, 1.6, 3.1%, respectively. Imprint cytology is valuable tool for evaluating TRUS-guided core needle biopsy specimens from the prostate. Use of imprint cytology in combination with histopathology increases diagnostic accuracy when compared with histopathologic assessment alone. © 2014 Wiley Periodicals, Inc.
Albitar, Maher; Ma, Wanlong; Lund, Lars; Shahbaba, Babak; Uchio, Edward; Feddersen, Søren; Moylan, Donald; Wojno, Kirk; Shore, Neal
2018-03-01
Distinguishing between low- and high-grade prostate cancers (PCa) is important, but biopsy may underestimate the actual grade of cancer. We have previously shown that urine/plasma-based prostate-specific biomarkers can predict high grade PCa. Our objective was to determine the accuracy of a test using cell-free RNA levels of biomarkers in predicting prostatectomy results. This multicenter community-based prospective study was conducted using urine/blood samples collected from 306 patients. All recruited patients were treatment-naïve, without metastases, and had been biopsied, designated a Gleason Score (GS) based on biopsy, and assigned to prostatectomy prior to participation in the study. The primary outcome measure was the urine/plasma test accuracy in predicting high grade PCa on prostatectomy compared with biopsy findings. Sensitivity and specificity were calculated using standard formulas, while comparisons between groups were performed using the Wilcoxon Rank Sum, Kruskal-Wallis, Chi-Square, and Fisher's exact test. GS as assigned by standard 10-12 core biopsies was 3 + 3 in 90 (29.4%), 3 + 4 in 122 (39.8%), 4 + 3 in 50 (16.3%), and > 4 + 3 in 44 (14.4%) patients. The urine/plasma assay confirmed a previous validation and was highly accurate in predicting the presence of high-grade PCa (Gleason ≥3 + 4) with sensitivity between 88% and 95% as verified by prostatectomy findings. GS was upgraded after prostatectomy in 27% of patients and downgraded in 12% of patients. This plasma/urine biomarker test accurately predicts high grade cancer as determined by prostatectomy with a sensitivity at 92-97%, while the sensitivity of core biopsies was 78%. © 2018 Wiley Periodicals, Inc.
Is it possible to predict low-volume and insignificant prostate cancer by core needle biopsies?
Berg, Kasper Drimer; Toft, Birgitte Grønkaer; Røder, Martin Andreas; Brasso, Klaus; Vainer, Ben; Iversen, Peter
2013-04-01
In an attempt to minimize overtreatment of localized prostate cancer (PCa) active surveillance (AS) and minor invasive procedures have received increased attention. We investigated the accuracy of pre-operative findings in defining insignificant disease and distinguishing between unilateral/unifocal and bilateral/multifocal PCa. One-hundred and sixty patients undergoing radical prostatectomy were included. Histology reports from the biopsies and matching prostatectomies were compared. Three definitions of insignificant cancer were used: InsigE: tumour volume ≤0.5 mL; InsigW: tumour volume ≤1.3 mL; InsigM: tumour ≤5% of total prostate volume and prostate-specific antigen (PSA) ≤10 ng/mL. In all definitions, Gleason score (GS) was ≤6 and the tumour was organ confined. Biopsies alone performed poorly as a predictor of unifocal and unilateral cancer in the prostatectomy specimens with positive predictive values of 17.8% and 18.9% respectively. Inclusion of other clinical and biochemical parameters did not significantly increase the predictive value. However, the combination of GS ≤ 6, PSA ≤ 10 ng/mL and unifocal or unilateral cancer in biopsy cores resulted in a positive predictive value of 61.1%, 38.9% and 12.0%, respectively, for identifying InsigM, InsigW and InsigE in the prostate specimen. Conclusively, routine prostate biopsies cannot predict unifocal and unilateral PCa, and must be regarded insufficient to select patients for focal therapy. Although candidates for AS may be identified using standard biopsies, a considerable fraction of patients will be understaged. There is a need for more precise diagnostic tools to assess intraprostatic tumour growth. © 2012 The Authors APMIS © 2012 APMIS.
Sennerstam, Roland B; Franzén, Bo S H; Wiksell, Hans O T; Auer, Gert U
2017-10-01
The literature offers discordant results regarding whether diagnostic biopsy is associated with the dissemination of cancer cells, resulting in local and/or distant metastasis. The long-term outcomes of patients with breast cancer were compared between those who were diagnosed using either fine-needle aspiration biopsy (FNAB) or core-needle biopsy (CNB) during 2 decades: the 1970s and 1990s. In the 1970s, the only diagnostic needle biopsy method used for breast cancer in Sweden was FNAB. CNB was introduced 1989 and became established in Stockholm Gotland County in the early 1990s. The authors compared the clinical outcomes of patients diagnosed using FNAB from 1971 to 1976 (n = 354) versus those of patients diagnosed using CNB from 1991 to 1995 (n = 1729). Adjusting for differences in various treatment modalities, mammography screening, tumor size, DNA ploidy, and patient age between the 2 decades, 2 strictly matched samples representing FNAB (n = 181) and CNB (n = 203) were selected for a 15-year follow-up study. In a comparison of the rates of distant metastasis in the strictly matched patient groups from the FNAB and CNB cohorts, significantly higher rates of late-appearing (5-15 years after diagnosis) distant metastasis were observed among the patients who were diagnosed on CNB compared with those who were diagnosed on FNAB. No significant difference in local metastasis was observed between the 2 groups. At 5 to 15 years after diagnosis of the primary tumor, CNB-diagnosed patients had significantly higher rates of distant metastases than FNAB-diagnosed patients. Cancer Cytopathol 2017;125:748-56. © 2017 American Cancer Society. © 2017 American Cancer Society.
Relea, A; Alonso, J A; González, M; Zornoza, C; Bahamonde, S; Viñuela, B E; Encinas, M B
2018-06-12
To determine whether the twinkling artifact on Doppler ultrasound imaging corresponds to microcalcifications previously seen on mammograms and to evaluate the usefulness of this finding in the ultrasound management of suspicious microcalcifications. We used ultrasonography to prospectively examine 46 consecutive patients with groups of microcalcifications suspicious for malignancy identified at mammography, searching for the presence of the twinkling artifact to identify the microcalcifications. Once we identified the microcalcifications, we obtained core-needle biopsy specimens with 11G needles and then used X-rays to check the specimens for the presence of microcalcifications. We analyzed the percentage of detection and obtainment of microcalcifications by core-needle biopsy with this technique and the radiopathologic correlation. Microcalcifications that were not detected by ultrasound or discordant lesions were biopsied by stereotaxy at another center. We also used ultrasound guidance for preoperative marking with clips, usually orienting them radially. We identified and biopsied 41 of the 46 lesions under ultrasound guidance, including 24 of 25 carcinomas (17 in situ). B-mode ultrasound was sufficient for biopsying the microcalcifications in 14 patients, although the presence of the twinkling artifact increased the number of microcalcifications detected and thus enabled more accurate preoperative marking. Thanks to the twinkling sign, we were able to identify 27 additional groups of microcalcifications (89% vs. 30%; p < 0.05). All the surgical specimens had margins free of disease. The twinkling artifact is useful for microcalcifications in ultrasound examinations, enabling a significant increase in the yield of ultrasound-guided biopsies and better preoperative marking of groups of microcalcifications. Copyright © 2018 SERAM. Publicado por Elsevier España, S.L.U. All rights reserved.
Trock, Bruce J; Fedor, Helen; Gurel, Bora; Jenkins, Robert B; Knudsen, B S; Fine, Samson W; Said, Jonathan W; Carter, H Ballentine; Lotan, Tamara L; De Marzo, Angelo M
2016-07-01
Men who enter active surveillance because their biopsy exhibits only Gleason grade 3 (G3) frequently have higher grade tumor missed by biopsy. Thus, biomarkers are needed that, when measured on G3 tissue, can predict the presence of higher grade tumor in the whole prostate. We evaluated whether PTEN loss, chromosome 8q gain (MYC) and/or 8p loss (LPL) measured only on G3 cores is associated with un-sampled G4 tumor. A tissue microarray was constructed of prostatectomy tissue from patients whose prostates exhibited only Gleason score 3+3, only 3+4 or only 4+3 tumor (n=50 per group). Cores sampled only from areas of G3 were evaluated for PTEN loss by immunohistochemistry, and PTEN deletion, LPL/8p loss and MYC/8q gain by fluorescence in situ hybridization. Biomarker results were compared between Gleason score 6 vs 7 tumors using conditional logistic regression. PTEN protein loss, odds ratio=4.99, P=0.033; MYC/8q gain, odds ratio=5.36, P=0.010; and LPL/8p loss, odds ratio=3.96, P=0.003 were significantly more common in G3 cores derived from Gleason 7 vs Gleason 6 tumors. PTEN gene deletion was not statistically significant. Associations were stronger comparing Gleason 4+3 vs 6 than for Gleason 3+4 vs 6. MYC/8q gain, LPL/8p loss and PTEN protein loss measured in G3 tissue microarray cores strongly differentiate whether the core comes from a Gleason 6 or Gleason 7 tumor. If validated to predict upgrading from G3 biopsy to prostatectomy these biomarkers could reduce the likelihood of enrolling high-risk men and facilitate safe patient selection for active surveillance.
Eleven-year management of prostate cancer patients on active surveillance: what have we learned?
Marenghi, Cristina; Alvisi, Maria Francesca; Palorini, Federica; Avuzzi, Barbara; Badenchini, Fabio; Bedini, Nice; Bellardita, Lara; Biasoni, Davide; Bosetti, Davide; Casale, Alessandra; Catanzaro, Mario; Colecchia, Maurizio; De Luca, Letizia; Donegani, Simona; Dordoni, Paola; Lanocita, Rodolfo; Maffezzini, Massimo; Magnani, Tiziana; Menichetti, Julia; Messina, Antonella; Morlino, Sara; Paolini, Biagio; Rancati, Tiziana; Stagni, Silvia; Tesone, Antonio; Torelli, Tullio; Tulli Baldoin, Edoardo; Vaiani, Marta; Villa, Sergio; Villa, Silvia; Zaffaroni, Nadia; Nicolai, Nicola; Salvioni, Roberto; Valdagni, Riccardo
2017-09-18
To evaluate the outcomes of active surveillance (AS) on patients with low-risk prostate cancer (PCa) and to identify predictors of disease reclassification. In 2005, we defined an institutional AS protocol (Sorveglianza Attiva Istituto Nazionale Tumori [SAINT]), and we joined the Prostate Cancer Research International: Active Surveillance (PRIAS) study in 2007. Eligibility criteria included clinical stage ≤T2a, initial prostate-specific antigen (PSA) <10 ng/mL, and Gleason Pattern Score (GPS) ≤3 + 3 (both protocols); ≤25% positive cores with a maximum core length containing cancer ≤50% (SAINT); and ≤2 positive cores and PSA density <0.2 ng/mL/cm3 (PRIAS). Switching to active treatment was advised for a worsening of GPS, increased positive cores, or PSA doubling time <3 years. Active treatment-free survival (ATFS) was assessed using the Kaplan-Meier method. Factors associated with ATFS were evaluated with a multivariate Cox proportional hazards model. A total of 818 patients were included: 200 in SAINT, 530 in PRIAS, and 88 in personalized AS monitoring. Active treatment-free survival was 50% after a median follow-up of 60 months. A total of 404/818 patients (49.4%) discontinued AS: 274 for biopsy-related reclassification, 121/404 (30%) for off-protocol reasons, 9/404 (2.2%) because of anxiety. Biopsy reclassification was associated with PSA density (hazard ratio [HR] 1.8), maximum percentage of core involvement (HR 1.5), positive cores at diagnostic biopsy (HR 1.6), older age (HR 1.5), and prostate volume (HR 0.6) (all p<0.01). Patients from SAINT were significantly more likely to discontinue AS than were the patients from PRIAS (HR 1.65, p<0.0001). Five years after diagnosis, 50% of patients with early PCa were spared from active treatment. Wide inclusion criteria are associated with lower ATFS. However, at preliminary analysis, this does not seem to affect the probability of unfavorable pathology.
Influence of persistent exchangeable oxygen on biogenic silica δ18O in deep sea cores
NASA Astrophysics Data System (ADS)
Menicucci, A. J.; Spero, H. J.
2016-12-01
The removal of exchangeable oxygen from biogenic opal prior to IRMS analysis is critical during sample preparation. Exchangeable oxygen is found in the form of hydroxyl and between defects within the amorphous silicate lattice structure. Typical analytical procedures utilize a variety of dehydroxylation methods to eliminate this exchangeable oxygen, including vacuum dehydroxylation and prefluorination. Such methods are generally considered sufficient for elimination of non-lattice bound oxygen that would obfuscate environmental oxygen isotopic signals contained within the silicate tetrahedra. δ18O data that are then empirically calibrated against modern hydrographic data, and applied down core in paleoceanographic applications. We have conducted a suite of experiments on purified marine opal samples using the new microfluorination method (Menicucci et al., 2013). Our data demonstrate that the amount of exchangeable oxygen in biogenic opal decreases as sample age/depth in core increases. These changes are not accounted for by current researchers. Further, our experimental data indicate that vacuum dehydroxylation does not eliminate all exchangeable oxygen, even after hydroxyl is undetectable. We have conducted experiments to quantify the amount of time necessary to ensure vacuum dehydroxylation has eliminated exchangeable oxygen so that opal samples are stable prior to δ18Odiatom analysis. Our experiments suggest that previously generated opal δ18O data may contain a variable down-core offset due to the presence of exchangeable, non-lattice bound oxygen sources. Our experiments indicate that diatom silica requires dehydroxylation for ≥ 44 hours at 1060oC to quantitatively remove all non-lattice bound oxygen. Further, this variable amount of exchangeable oxygen may be responsible for some of the disagreement between existing empirical calibrations based on core-top diatom frustule remains. Analysis of δ18Odiatom values after this long vacuum dehydroxylation time is necessary for quantitative comparisons of stable isotopic values across geologic time periods. Menicucci, A. J., et al. (2013). "Oxygen isotope analyses of biogenic opal and quartz using a novel microfluorination technique." Rapid Communications in Mass Spectrometry 27(16): 1873-1881
Lin, Chia-Ying; Ou, Ming-Ching; Liu, Yi-Sheng; Chuang, Ming-Tsung; Shan, Yan-Shen; Tsai, Hong-Ming; Wang, Chien-Kuo; Tsai, Yi-Shan
2017-01-01
Background/Aims: The purpose of this study is to report our results using a computed tomography (CT)-guided fat transversing coaxial biopsy technique for pancreatic lesion biopsy that avoids major organs and vessels. We retrospectively reviewed the records of patients referred to our department for pancreatic mass biopsy. Patients and Methods: The records of patients (from June 2008 to August 2014) in whom biopsy was performed under CT guidance with a coaxial needle using a fat transversing technique were reviewed. Patient demographic data and biopsy outcomes were collected. We aimed to compare differences between lesion size and biopsy outcome, the independent two-samples t-test was used. Results: A total of 122 patients who underwent 17-G coaxial needle biopsy were included. The mean pancreatic lesion size was 3.2 cm, and in 30 patients it was more than 4 cm. The majority of lesions were located in the head of the pancreas (44.3%). No transorgan biopsies were performed. In most patients, the biopsy was performed via a fat traversing detour route (93.4%), and a successful diagnosis was made based on the biopsy outcome in 96.7% patients. Complications occurred in five patients (4.1%); three of the patients developed a fever, and two developed pancreatitis. All patients recovered with symptomatic treatment. Conclusion: CT-guided coaxial core biopsy of pancreatic lesions using a fat detour route appears to be a safe and effective method for obtaining pancreatic lesion biopsies with a high success rate and low complication rate. PMID:29205187
Mechanism Guides Hatch Through Hatchway
NASA Technical Reports Server (NTRS)
Barron, Daniel R.; Kennedy, Steven E.
1993-01-01
Elliptical hatch designed to move through hatchway to make pressure-assisted seal with either side of bulkhead. Compact three-degree-of-freedom mechanism guides hatch through hatchway or holds hatch off to one side to facilitate passage of crew and/or equipment. Hatches and mechanisms used in submarines, pressure chambers (including hyperbaric treatment chambers), vacuum chambers, and vacuum-or-pressure test chambers.
Washino, Satoshi; Okochi, Tomohisa; Saito, Kimitoshi; Konishi, Tsuzumi; Hirai, Masaru; Kobayashi, Yutaka; Miyagawa, Tomoaki
2017-02-01
To assess the value of the Prostate Imaging Reporting and Data System (PI-RADS) scoring system, for prostate multi-parametric magnetic resonance imaging (mpMRI) to detect prostate cancer, and classical parameters, such as prostate-specific antigen (PSA) level, prostate volume and PSA density, for predicting biopsy outcome in biopsy naïve patients who have suspected prostate cancer. Patients who underwent mpMRI at our hospital, and who had their first prostate biopsy between July 2010 and April 2014, were analysed retrospectively. The prostate biopsies were taken transperineally under transrectal ultrasonography guidance. In all, 14 cores were biopsied as a systematic biopsy in all patients. Two cognitive fusion-targeted biopsy cores were added for each lesion in patients who had suspicious or equivocal lesions on mpMRI. The PI-RADS scoring system version 2.0 (PI-RADS v2) was used to describe the MRI findings. Univariate and multivariate analyses were performed to determine significant predictors of prostate cancer and clinically significant prostate cancer. In all, 288 patients were analysed. The median patient age, PSA level, prostate volume and PSA density were 69 years, 7.5 ng/mL, 28.7 mL, and 0.26 ng/mL/mL, respectively. The biopsy results were benign, clinically insignificant, and clinically significant prostate cancer in 129 (45%), 18 (6%) and 141 (49%) patients, respectively. The multivariate analysis revealed that PI-RADS v2 score and PSA density were independent predictors for prostate cancer and clinically significant prostate cancer. When PI-RADS v2 score and PSA density were combined, a PI-RADS v2 score of ≥4 and PSA density ≥0.15 ng/mL/mL, or PI-RADS v2 score of 3 and PSA density of ≥0.30 ng/mL/mL, was associated with the highest clinically significant prostate cancer detection rates (76-97%) on the first biopsy. Of the patients in this group with negative biopsy results, 22% were subsequently diagnosed as prostate cancer. In contrast, a PI-RADS v2 score of ≤3 and PSA density of <0.15 ng/mL/mL yielded no clinically significant prostate cancer and no additional detection of prostate cancer on further biopsies. A combination of PI-RADS v2 score and PSA density can help in the decision-making process before prostate biopsy and in the follow-up strategy in biopsy naïve patients. Patients with a PI-RADS v2 score of ≤3 and PSA density of <0.15 ng/mL/mL may avoid unnecessary biopsies. © 2016 The Authors BJU International published by John Wiley & Sons Ltd on behalf of BJU International.
2012-01-01
Background The study of breast cancer metastasis depends on the use of established breast cancer cell lines that do not accurately represent the heterogeneity and complexity of human breast tumors. A tumor model was developed using primary breast tumor-initiating cells isolated from patient core biopsies that would more accurately reflect human breast cancer metastasis. Methods Tumorspheres were isolated under serum-free culture conditions from core biopsies collected from five patients with clinical diagnosis of invasive ductal carcinoma (IDC). Isolated tumorspheres were transplanted into the mammary fat pad of NUDE mice to establish tumorigenicity in vivo. Tumors and metastatic lesions were analyzed by hematoxylin and eosin (H+E) staining and immunohistochemistry (IHC). Results Tumorspheres were successfully isolated from all patient core biopsies, independent of the estrogen receptor α (ERα)/progesterone receptor (PR)/Her2/neu status or tumor grade. Each tumorsphere was estimated to contain 50-100 cells. Transplantation of 50 tumorspheres (1-5 × 103 cells) in combination with Matrigel into the mammary fat pad of NUDE mice resulted in small, palpable tumors that were sustained up to 12 months post-injection. Tumors were serially transplanted three times by re-isolation of tumorspheres from the tumors and injection into the mammary fat pad of NUDE mice. At 3 months post-injection, micrometastases to the lung, liver, kidneys, brain and femur were detected by measuring content of human chromosome 17. Visible macrometastases were detected in the lung, liver and kidneys by 6 months post-injection. Primary tumors variably expressed cytokeratins, Her2/neu, cytoplasmic E-cadherin, nuclear β catenin and fibronectin but were negative for ERα and vimentin. In lung and liver metastases, variable redistribution of E-cadherin and β catenin to the membrane of tumor cells was observed. ERα was re-expressed in lung metastatic cells in two of five samples. Conclusions Tumorspheres isolated under defined culture conditions from patient core biopsies were tumorigenic when transplanted into the mammary fat pad of NUDE mice, and metastasized to multiple mouse organs. Micrometastases in mouse organs demonstrated a dormancy period prior to outgrowth of macrometastases. The development of macrometastases with organ-specific phenotypic distinctions provides a superior model for the investigation of organ-specific effects on metastatic cancer cell survival and growth. PMID:22233382
Prognostic parameter for high risk prostate cancer patients at initial presentation.
Kato, Masashi; Kimura, Kyosuke; Hirakawa, Akihiro; Kobayashi, Yumiko; Ishida, Ryo; Kamihira, Osamu; Majima, Tsuyoshi; Funahashi, Yasuhito; Sassa, Naoto; Matsukawa, Yoshihisa; Hattori, Ryohei; Gotoh, Momokazu; Tsuzuki, Toyonori
2018-01-01
High-risk prostate cancer can be defined by a patient's Gleason score (GS), prostate-specific antigen (PSA) level, and clinical T (cT) stage, but a novel marker is needed due to heterogeneity of the disease. In this study, we evaluated whether intraductal carcinoma of the prostate (IDC-P) confirmed by needle biopsy is an adverse prognostic parameter for progression-free survival (PFS) and cancer-specific survival (CSS) in patients with high-risk prostate cancer. We retrospectively evaluated 204 patients with high-risk prostate cancer treated by radical prostatectomy from 1991 to 2005 at Nagoya University and its affiliated hospitals. Data on each patient's PSA level, biopsy GS, cT stage, presence of Gleason pattern 5, presence of IDC-P, percentage of the core involved with cancer, and maximum percentage of the core involved with cancer were analyzed. The median follow-up period was 108 months (range, 11-257 months). Forty-eight patients (24%) showed disease progression. Thirty-four patients (17%) died of the disease during follow-up. The IDC-P component was detected in 74 (36%) needle biopsy samples. The 5-, 10-, and 15-year CSS rates of the IDC-P-negative cases were 3.2%, 9.0%, and 23.7%; the corresponding rates of the IDC-P-positive cases were 23.9%, 33.7%, and 52.7%, respectively (P = 0.0001). In the Fine and Gray's model for PFS, IDC-P, maximum percentage of the core involved with cancer, and cT stage were significantly associated (P = 0.013, P = 0.003, P = 0.007). In the Fine and Gray's model for CSS, only IDC-P was significant (P = 0.027). In a multivariate Cox regression analysis, IDC-P (P = 0.04; hazard ratio [HR], 1.95) and maximum percentage of the core involved with cancer (P = 0.021; HR, 0.43) were significant factors in predicting overall survival (OS). The presence of IDC-P in a needle biopsy was a prognostic factor for PFS, CSS, and OS in patients with high-risk prostate cancer who underwent radical prostatectomy. Multimodal pre-and/or post- surgical therapy may be needed when IDC-P is found in a needle biopsy specimen. © 2017 Wiley Periodicals, Inc.
Medical management of cutaneous sulfur mustard injuries.
Graham, John S; Stevenson, Robert S; Mitcheltree, Larry W; Hamilton, Tracey A; Deckert, Robin R; Lee, Robyn B; Schiavetta, Ann M
2009-09-01
Sulfur mustard (2,2'-dichlorodiethyl sulfide; HD) is a potent vesicating chemical warfare agent that poses a continuing threat to both military and civilian populations. Significant cutaneous HD injuries can take several months to heal, necessitate lengthy hospitalizations, and result in long-term complications. There are currently no standardized or optimized methods of casualty management. New strategies are needed to provide for optimal and rapid wound healing. The primary aim of this research was to develop improved clinical strategies (treatment guidelines) for optimal treatment of superficial dermal (second degree) cutaneous HD injuries, with the goal of returning damaged skin to optimal appearance and normal function in the shortest period of time. Superficial dermal HD injuries were created on the ventral abdominal surface of weanling pigs. At 48h post-exposure, lesions were laser debrided and a treatment adjunct applied. Cultured epithelial allografts and 11 commercial off-the-shelf (COTS) products were examined for their efficacy in improving wound healing of these injuries. Clinical evaluations and a variety of non-invasive bioengineering methods were used at 7 and 14 days post-surgery to follow the progress of wound healing and evaluate various cosmetic and functional properties of the wounds. Measurements included reflectance colorimetry to measure erythema; evaporimetry to examine transepidermal water loss as a method of evaluating barrier function; torsional ballistometry to evaluate the mechanical properties of skin firmness and elasticity; and two-dimensional high frequency ultrasonography (HFU) to monitor skin thickness (e.g., edema, scar tissue). Histopathology and immunohistochemistry were performed 14 days following surgery to examine structural integrity and quality of healing. Logical Decisions((R)) for Windows was used to rank the 12 treatment adjuncts that were studied. The most efficacious treatment adjuncts included (1) Vacuum Assisted Closure, V.A.C., involving application of topical negative pressure, (2) Amino-Plex Spray (biO(2) Cosmeceuticals International, Inc., Beverly Hills, CA), a nutritive cosmeceutical product that is designed to increase oxygen in cells, stimulate ATP synthesis, improve glucose transportation, stimulate collagen formation, and promote angiogenesis, and (3) ReCell Autologous Cell Harvesting Device (Clinical Cell Culture Americas LLC, Coral Springs, Florida), an innovative medical device that was developed to allow rapid harvesting of autologous cells from a thin split-thickness biopsy followed by spray application of a population of skin cells onto wounds within 30 min of collecting the biopsy, without the need of culturing the keratinocytes in a clinical laboratory. Complete re-epithelialization of debrided HD injuries in 7 days is possible. In general, shallow laser debridement through the basement membrane zone (100 microm) appears to provide better results than deeper debridement (400 microm) with respect to early re-epithelialization, cosmetic appearance, functional restoration, and structural integrity. Of the 12 treatment adjuncts examined, the most promising included Vacuum Assisted Closure, Amino-Plex Spray, and ReCell Autologous Cell Harvesting Device.
van Leeuwen, Pim J; Hayen, Andrew; Thompson, James E; Moses, Daniel; Shnier, Ron; Böhm, Maret; Abuodha, Magdaline; Haynes, Anne-Maree; Ting, Francis; Barentsz, Jelle; Roobol, Monique; Vass, Justin; Rasiah, Krishan; Delprado, Warick; Stricker, Phillip D
2017-12-01
To develop and externally validate a predictive model for detection of significant prostate cancer. Development of the model was based on a prospective cohort including 393 men who underwent multiparametric magnetic resonance imaging (mpMRI) before biopsy. External validity of the model was then examined retrospectively in 198 men from a separate institution whom underwent mpMRI followed by biopsy for abnormal prostate-specific antigen (PSA) level or digital rectal examination (DRE). A model was developed with age, PSA level, DRE, prostate volume, previous biopsy, and Prostate Imaging Reporting and Data System (PIRADS) score, as predictors for significant prostate cancer (Gleason 7 with >5% grade 4, ≥20% cores positive or ≥7 mm of cancer in any core). Probability was studied via logistic regression. Discriminatory performance was quantified by concordance statistics and internally validated with bootstrap resampling. In all, 393 men had complete data and 149 (37.9%) had significant prostate cancer. While the variable model had good accuracy in predicting significant prostate cancer, area under the curve (AUC) of 0.80, the advanced model (incorporating mpMRI) had a significantly higher AUC of 0.88 (P < 0.001). The model was well calibrated in internal and external validation. Decision analysis showed that use of the advanced model in practice would improve biopsy outcome predictions. Clinical application of the model would reduce 28% of biopsies, whilst missing 2.6% significant prostate cancer. Individualised risk assessment of significant prostate cancer using a predictive model that incorporates mpMRI PIRADS score and clinical data allows a considerable reduction in unnecessary biopsies and reduction of the risk of over-detection of insignificant prostate cancer at the cost of a very small increase in the number of significant cancers missed. © 2017 The Authors BJU International © 2017 BJU International Published by John Wiley & Sons Ltd.
Large-aperture plasma-assisted deposition of inertial confinement fusion laser coatings.
Oliver, James B; Kupinski, Pete; Rigatti, Amy L; Schmid, Ansgar W; Lambropoulos, John C; Papernov, Semyon; Kozlov, Alexei; Spaulding, John; Sadowski, Daniel; Chrzan, Z Roman; Hand, Robert D; Gibson, Desmond R; Brinkley, Ian; Placido, Frank
2011-03-20
Plasma-assisted electron-beam evaporation leads to changes in the crystallinity, density, and stresses of thin films. A dual-source plasma system provides stress control of large-aperture, high-fluence coatings used in vacuum for substrates 1m in aperture.
Yan, Lei; Ikemura, Kenji; Park, Ji-Weon
2018-02-01
Endoscopic ultrasound-guided fine-needle aspiration (EUS-FNA) and endoscopic ultrasound-guided core-needle biopsy (EUS-CNB) are widely used for diagnosis of pancreatic tumors. The aim of our study was to compare the diagnostic performance of ROSE EUS-FNA and EUS-CNB for diagnosis of pancreatic malignancy during the same EUS. Patients who underwent both FNA and CNB during the same EUS for pancreatic solid lesion were reviewed retrospectively. Sample adequacy, diagnostic yield (defined as percentage of definitive diagnosis), sensitivity and specificity for malignancy were compared between FNA and CNB. A total of 48 patients with solid pancreatic lesions were evaluated. The proportions of adequate samples were 48/48 (100%) for FNA and 45/48 (93.7%) for core biopsy (P = .24). The diagnostic yield was 42/48 (87.5%) and 33/48 (68.7%) for FNA and CNB respectively (P = .046). The incremental increase in diagnostic yield by combining both methods was 2/48 (4%). The diagnostic yield for malignancy was 30/32 (93.7%) for FNA and 23/32 (71.8%) for CNB (P = .043). The sensitivity for the diagnosis of malignancy for FNA and CNB were 90.6% and 69%, respectively (P = .045). The specificity was 100% for both methods. The sensitivity for diagnosing malignancy increased to 93.8% when the two methods were combined. The difference in diagnostic yield was not associated with lesion size or location. EUS-guided FNA is a superior method of assessing solid pancreatic lesion and pancreatic malignancy with better diagnostic yield and higher sensitivity than EUS-CNB. © 2017 Wiley Periodicals, Inc.
Hara, Tomohiko; Nakanishi, Hiroyuki; Nakagawa, Tohru; Komiyama, Motokiyo; Kawahara, Takashi; Manabe, Tomoko; Miyake, Mototaka; Arai, Eri; Kanai, Yae; Fujimoto, Hiroyuki
2013-10-01
Recent studies have shown an improvement in prostate cancer diagnosis with the use of 3.0-Tesla magnetic resonance imaging. We retrospectively assessed the ability of this imaging technique to predict side-specific extracapsular extension of prostate cancer. From October 2007 to August 2011, prostatectomy was carried out in 396 patients after preoperative 3.0-Tesla magnetic resonance imaging. Among these, 132 (primary sample) and 134 patients (validation sample) underwent 12-core prostate biopsy at the National Cancer Center Hospital of Tokyo, Japan, and at other institutions, respectively. In the primary dataset, univariate and multivariate analyses were carried out to predict side-specific extracapsular extension using variables determined preoperatively, including 3.0-Tesla magnetic resonance imaging findings (T2-weighted and diffusion-weighted imaging). A prediction model was then constructed and applied to the validation study sample. Multivariate analysis identified four significant independent predictors (P < 0.05), including a biopsy Gleason score of ≥8, positive 3.0-Tesla diffusion-weighted magnetic resonance imaging findings, ≥2 positive biopsy cores on each side and a maximum percentage of positive cores ≥31% on each side. The negative predictive value was 93.9% in the combination model with these four predictors, meanwhile the positive predictive value was 33.8%. Good reproducibility of these four significant predictors and the combination model was observed in the validation study sample. The side-specific extracapsular extension prediction by the biopsy Gleason score and factors associated with tumor location, including a positive 3.0-Tesla diffusion-weighted magnetic resonance imaging finding, have a high negative predictive value, but a low positive predictive value. © 2013 The Japanese Urological Association.
Gu, Huiyan; Chen, Fengli; Zhang, Qiang; Zang, Jing
2016-03-01
Rutin, hyperoside and hesperidin were effectively extracted from Sorbus tianschanica leaves by an ionic liquid vacuum microwave-assisted method. A series of ionic liquids with various anions and alkyl chain length of the cations were studied and the extraction was performed in [C6mim][BF4] aqueous solution. After optimization by a factorial design and response surface methodology, total extraction yield of 2.37mg/g with an error of 0.12mg/g (0.71±0.04mg/g, 1.18±0.06mg/g and 0.48±0.02 for rutin, hyperoside and hesperidin, respectively) was achieved under -0.08MPa for vacuum, 19min and 420W for microwave irradiation time and power, and 15mL/g for liquid-solid ratio. The proposed method here is more efficient and needs a shorter extraction time for rutin, hyperoside and hesperidin from S. tianschanica leaves than reference extraction techniques. In stability studies performed with standard rutin, hyperoside and hesperidin, the target analytes were stable under the optimum conditions. The proposed method had a high reproducibility and precision. In addition, separation of rutin, hyperoside and hesperidin from [C6mim][BF4] extraction solution was completed effectively by AB-8 macroporous resin adsorption and desorption process. Ionic liquid vacuum microwave-assisted extraction is a simple, rapid and efficient sample extraction technique. Copyright © 2016 Elsevier B.V. All rights reserved.
Kominsky, Hal D; Bashline, Michael; Eun, Daniel; Pontari, Michel A; Mydlo, Jack H; Reese, Adam C
2017-02-01
To assess life expectancy and biopsy outcomes in men undergoing prostate biopsy at an academic medical center. We analyzed men who underwent prostate biopsy at our medical center between July 2012 and June 2014. Long-term other-cause mortality risk was determined using survival tables. Indications for biopsy and biopsy outcomes were assessed, and compared among men with varying mortality risks. A total of 417 men underwent prostate biopsy, in whom 14-year other-cause mortality risk ranged from 9% to 74%. One hundred ninety-three men (46.3%) were considered low-mortality risk (<40% risk of 14-year mortality), 131 (31.4%) intermediate risk (41%-55% 14-year mortality), and 93 (22.3%) high risk (>55% 14-year mortality). Of the 417 patients who underwent biopsy, 149 (35.7%) were found to have prostate cancer. There was no significant difference in the rate of positive biopsies (P = .72), distribution of Gleason scores (P = .60), or percentage of positive biopsy cores (P = .74) between mortality risk groups. However, by UCSF Cancer of the Prostate Risk Assessment score, there was significant trend toward higher-risk prostate cancer in men with intermediate and high-mortality risk (P = .04). In this analysis, a large number of men with limited life expectancies underwent prostate biopsy. The majority of these men had negative biopsies or low-risk cancers, suggesting that they were unlikely to benefit from biopsy. To avoid potentially unnecessary prostate biopsies, the practitioner must give serious consideration to a patient's age and medical comorbidities before making a recommendation as to whether biopsy should be performed. Copyright © 2016 Elsevier Inc. All rights reserved.
Lung biopsy with a 12-gauge cutting needle is possible using an insertion sheath in animal models.
Izumi, Yotaro; Oyama, Takahiko; Kawamura, Masafumi; Kobayashi, Koichi
2004-11-01
The volume of lung tumor core biopsy specimens has been restricted because of concerns for complications such as bleeding and air leakage. In this animal experiment, we investigated the possibility of larger bore biopsies through the peripheral lung parenchyma. Lung biopsy was done in male domestic pigs (n= 4) under thoracotomy. A single biopsy using a 12-gauge cutting biopsy needle was done with sheath (sheath group, eight biopsies) or without sheath (nonsheath group, eight biopsies). After biopsy, bleeding time, bleeding amount, and positive airway pressure causing air leakage from the insertion site was compared between groups (Mann-Whitney U test). To observe long-term effects in closed-chest animals, percutaneous lung biopsy with the use of a sheath was carried out percutaneously in male beagles (n = 9). The animals were observed for 3 weeks. In the pigs (sheath group) after biopsy, bleeding flowed through the sheath and formed a sheath-molded fibrin plug that secured the insertion site. Bleeding time and amount decreased significantly in the sheath group compared with the nonsheath group (115 +/- 108 versus 295 +/- 150 seconds, P = .018, and 37 +/- 41 versus 98 +/- 72 grams, P= .027, respectively). Air leakage pressure was significantly higher in the sheath group compared with the nonsheath group (37 +/- 6 versus 18 +/- 5 cmH2O, P = .001). In the beagles, no complications such as pneumothorax, hemothorax, or airway bleeding was apparent. Although we have not evaluated lung tumor biopsy per se, lung tumor biopsy with a 12-gauge cutting needle may be possible with a use of a sheath.
Gellert, Pascal; Segal, Corrinne V; Gao, Qiong; López-Knowles, Elena; Martin, Lesley-Ann; Dodson, Andrew; Li, Tiandao; Miller, Christopher A; Lu, Charles; Mardis, Elaine R; Gillman, Alexa; Morden, James; Graf, Manuela; Sidhu, Kally; Evans, Abigail; Shere, Michael; Holcombe, Christopher; McIntosh, Stuart A; Bundred, Nigel; Skene, Anthony; Maxwell, William; Robertson, John; Bliss, Judith M; Smith, Ian; Dowsett, Mitch
2016-11-09
Pre-surgical studies allow study of the relationship between mutations and response of oestrogen receptor-positive (ER+) breast cancer to aromatase inhibitors (AIs) but have been limited to small biopsies. Here in phase I of this study, we perform exome sequencing on baseline, surgical core-cuts and blood from 60 patients (40 AI treated, 20 controls). In poor responders (based on Ki67 change), we find significantly more somatic mutations than good responders. Subclones exclusive to baseline or surgical cores occur in ∼30% of tumours. In phase II, we combine targeted sequencing on another 28 treated patients with phase I. We find six genes frequently mutated: PIK3CA, TP53, CDH1, MLL3, ABCA13 and FLG with 71% concordance between paired cores. TP53 mutations are associated with poor response. We conclude that multiple biopsies are essential for confident mutational profiling of ER+ breast cancer and TP53 mutations are associated with resistance to oestrogen deprivation therapy.
Caretta-Weyer, Holly; Sisney, Gale A; Beckman, Catherine; Burnside, Elizabeth S; Salkowsi, Lonie R; Strigel, Roberta M; Wilke, Lee G; Neuman, Heather B
2012-09-01
Our objective was to evaluate the impact of preoperative axillary ultrasound and core needle biopsy (CNB) on breast cancer treatment decision making. A secondary aim was to evaluate the impact on the utility of intraoperative sentinel lymph node (SLN) frozen section. A review of 84 patients with clinically negative axilla who underwent axillary ultrasound was performed. Sensitivity, specificity, and positive/negative predictive value for axillary ultrasound with CNB was calculated. Thirty-one (37%) had suspicious nodes. Of 27 amenable to CNB, 12 (14%) were malignant, changing treatment plans. The sensitivity of ultrasound and CNB was 54% and specificity 100%; the positive and negative predictive values were 100% and 80%, respectively. In 41 patients with normal ultrasounds who underwent SLN frozen section, 10 (24%) were positive. Preoperative axillary ultrasound impacts treatment decision making in 14%. With a sensitivity of 54%, it is a useful adjunct to, but not replacement for, SLN biopsy. Frozen section remains of utility even after a negative axillary ultrasound. Copyright © 2012 Elsevier Inc. All rights reserved.
Lieu, David
2009-04-01
Fine-needle aspiration (FNA) of breast masses in the United States has been on the decline for the last decade and has been largely replaced by ultrasound-guided core-needle biopsy (UG-CNB). Some studies show core-needle biopsy (CNB) is superior to FNA in terms of absolute sensitivity, specificity, and inadequate rate. However, the importance of a skilled aspirator, experienced cytopathologist, and immediate cytological evaluation (ICE) in FNA is often not considered. CNB is more expensive, invasive, risky, and painful than FNA. This prospective study examines the value of cytopathologist-performed ultrasound-guided FNA (UG-FNA) with ICE as a screening test for cytopathologist-performed UG-CNB on nonpalpable or difficult-to-palpate solid breast masses visible on ultrasound. One hundred twenty consecutive nonpalpable or difficult-to-palpate presumably solid breast masses in 109 female patients from January2, 2008 to June 30, 2008 underwent cytopathologist-performed UG-FNA with ICE. Twenty cases were converted to cytopathologist-performed UG-CNB because ICE was inadequate, hypocellular, atypical, suspicious, or malignant. Patients with clearly benign cytology did not undergo UG-CNB. UG-FNA with ICE reduced the percentage of patients undergoing UG-CNB by 87%. A new role for cytopathologist-performed UG-FNA of nonpalpable breast masses has been identified.
Evolution of prostate biopsy techniques. Looking back on a meaningful journey.
Sivaraman, A; Sanchez-Salas, R; Castro-Marin, M; Barret, E; Guillot-Tantay, C; Prapotnich, D; Cathelineau, X
2016-10-01
The technique of prostate biopsy has evolved a long way since its inception to being a safe diagnostic procedure. The principles of the biopsy technique continue to improvise with the knowledge about prostate cancer and availability of newer treatment options like active surveillance and focal therapy. Currently, we depend on accurate cancer information from the biopsy more than ever for deciding the ideal treatment option. The aim of this review is to present the major milestones in prostate biopsy technique evolutions and its impact on the prostate cancer management. We performed a detailed non-systematic literature review to present the historical facts on the transformations in prostate biopsy techniques and also the direction of present research to improve accurate cancer detection. There is a clear change in trend in biopsy technique before and after the introduction of transrectal ultrasound and prostate specific antigen. In the earlier era, the biopsies were aimed at palpable nodules and obtaining adequate prostatic tissue for diagnosis while the later era has moved towards detection of non-palpable and early prostate cancer. Recently, there is an increasing trend towards image guided targeted biopsies to extract maximum cancer information from minimum biopsy cores. Prostate biopsy techniques have seen major changes since its inception and have a major impact on prostate cancer management. There is a great potential for research which can further support the newer treatment options like focal therapy. Copyright © 2016 AEU. Publicado por Elsevier España, S.L.U. All rights reserved.
2011-01-01
Background Cancer of the oral cavity is the sixth most common malignancy reported worldwide and one with the highest mortality rate among all malignancies. There is a paucity of reliable diagnostic methods to detect early malignancies. This study was performed to evaluate the sensitivity and specificity of brush biopsy in identifying oral premalignant and malignant lesions. Methods Oral brush and scalpel biopsies were performed on 85 consecutive patients presenting with an oral lesion deemed to be minimally suspicious by clinical examination and the results were compared. Results Of 79 patients with adequate brush biopsy samples with matching scalpel biopsies, 27 revealed histopathologic evidence of dysplasia or carcinoma, 26 of which were independently identified with the oral brush biopsy (sensitivity: 96.3% - 95% CI, 87%-100%). 52 oral lesions did not reveal any histopathologic evidence of dysplasia or carcinoma and of these, brush biopsy reported 47 as "negative" and 5 as "atypical"(specificity of "positive" brush biopsy result is 100%- 95% CI, 93%-100%; specificity for "atypical" brush biopsy result is 90.4%- 95% CI, 82%-97%. The positive predictive value of an abnormal oral brush biopsy was 84% and the negative predictive value was 98%. Conclusion Our study demonstrated that the oral brush biopsy is an accurate test in identifying oral premalignant and malignant lesions, even if minimally suspicious. PMID:21864339
Faiella, Eliodoro; Santucci, Domiziana; Greco, Federico; Frauenfelder, Giulia; Giacobbe, Viola; Muto, Giovanni; Zobel, Bruno Beomonte; Grasso, Rosario Francesco
2018-02-01
To evaluate the diagnostic accuracy of mp-MRI correlating US/mp-MRI fusion-guided biopsy with systematic random US-guided biopsy in prostate cancer diagnosis. 137 suspected prostatic abnormalities were identified on mp-MRI (1.5T) in 96 patients and classified according to PI-RADS score v2. All target lesions underwent US/mp-MRI fusion biopsy and prostatic sampling was completed by US-guided systematic random 12-core biopsies. Histological analysis and Gleason score were established for all the samples, both target lesions defined by mp-MRI, and random biopsies. PI-RADS score was correlated with the histological results, divided in three groups (benign tissue, atypia and carcinoma) and with Gleason groups, divided in four categories considering the new Grading system of the ISUP 2014, using t test. Multivariate analysis was used to correlate PI-RADS and Gleason categories to PSA level and abnormalities axial diameter. When the random core biopsies showed carcinoma (mp-MRI false-negatives), PSA value and lesions Gleason median value were compared with those of carcinomas identified by mp-MRI (true-positives), using t test. There was statistically significant difference between PI-RADS score in carcinoma, atypia and benign lesions groups (4.41, 3.61 and 3.24, respectively) and between PI-RADS score in Gleason < 7 group and Gleason > 7 group (4.14 and 4.79, respectively). mp-MRI performance was more accurate for lesions > 15 mm and in patients with PSA > 6 ng/ml. In systematic sampling, 130 (11.25%) mp-MRI false-negative were identified. There was no statistic difference in Gleason median value (7.0 vs 7.06) between this group and the mp-MRI true-positives, but a significant lower PSA median value was demonstrated (7.08 vs 7.53 ng/ml). mp-MRI remains the imaging modality of choice to identify PCa lesions. Integrating US-guided random sampling with US/mp-MRI fusion target lesions sampling, 3.49% of false-negative were identified.
Afonso, P. Diana; Vinson, Emily N.; Turnbull, James D.; Morris, Karla K.; Foye, Adam; Madden, John F.; Roy Choudhury, Kingshuk; Febbo, Phillip G.; George, Daniel J.
2013-01-01
Purpose To determine the rate at which computed tomographically guided pelvic percutaneous bone biopsy in men with metastatic castration-resistant prostate cancer (mCRPC) yields adequate tissue for genomic profiling and to identify issues likely to affect diagnostic yields. Materials and Methods This study was institutional review board approved, and written informed consent was obtained. In a phase II trial assessing response to everolimus, 31 men with mCRPC underwent 54 biopsy procedures (eight men before and 23 men both before and during treatment). Variables assessed were lesion location (iliac wing adjacent to sacroiliac joint, iliac wing anterior and/or superior to sacroiliac joint, sacrum, and remainder of pelvis), mean lesion attenuation, subjective lesion attenuation (purely sclerotic vs mixed), central versus peripheral lesion sampling, lesion size, core number, and use of zoledronic acid for more than 1 year. Results Of 54 biopsy procedures, 21 (39%) yielded adequate tissue for RNA isolation and genomic profiling. Three of four sacral biopsies were adequate. Biopsies of the ilium adjacent to the sacroiliac joints were more likely adequate than those from elsewhere in the ilium (48% vs 28%, respectively). All five biopsies performed in other pelvic locations yielded inadequate tissue for RNA isolation. Mean attenuation of lesions with inadequate tissue was 172 HU greater than those with adequate tissue (621.1 HU ± 166 vs 449 HU ± 221, respectively; P = .002). Use of zoledronic acid, peripheral sampling, core number, and lesion size affected yields, but the differences were not statistically significant. Histologic examination with hematoxylin-eosin staining showed that results of 36 (67%) biopsies were positive for cancer; only mean attenuation differences were significant (707 HU ± 144 vs 473 HU ± 191, negative vs positive, respectively; P < .001). Conclusion In men with mCRPC, percutaneous sampling of osseous metastases for genomic profiling is possible, but use of zoledronic acid for more than 1 year may reduce the yield of adequate tissue for RNA isolation. Sampling large low-attenuating lesions at their periphery maximizes yield. © RSNA, 2013 PMID:23925271
Infrared needle mapping to assist biopsy procedures and training.
Shar, Bruce; Leis, John; Coucher, John
2018-04-01
A computed tomography (CT) biopsy is a radiological procedure which involves using a needle to withdraw tissue or a fluid specimen from a lesion of interest inside a patient's body. The needle is progressively advanced into the patient's body, guided by the most recent CT scan. CT guided biopsies invariably expose patients to high dosages of radiation, due to the number of scans required whilst the needle is advanced. This study details the design of a novel method to aid biopsy procedures using infrared cameras. Two cameras are used to image the biopsy needle area, from which the proposed algorithm computes an estimate of the needle endpoint, which is projected onto the CT image space. This estimated position may be used to guide the needle between scans, and results in a reduction in the number of CT scans that need to be performed during the biopsy procedure. The authors formulate a 2D augmentation system which compensates for camera pose, and show that multiple low-cost infrared imaging devices provide a promising approach.
2015-10-01
2011;92:1570– 1575 . 12. Ferraro C. Outcomes study of transtibial amputees using elevated vacuum suspension in comparison with pin suspension. J Prosthet...Amputees: Effect on Fit, Activity, and Limb Volume,” Arch. Phys. Med. Rehabil., 92(10), pp. 1570– 1575 . [6] Hoskins, R. D., Sutton, E. E., Kinor, D
Lange, P; Greco, K; Partington, L; Carvalho, C; Oliani, S; Birchall, M A; Sibbons, P D; Lowdell, M W; Ansari, T
2017-03-01
Tissue engineered tracheae have been successfully implanted to treat a small number of patients on compassionate grounds. The treatment has not become mainstream due to the time taken to produce the scaffold and the resultant financial costs. We have developed a method for decellularization (DC) based on vacuum technology, which when combined with an enzyme/detergent protocol significantly reduces the time required to create clinically suitable scaffolds. We have applied this technology to prepare porcine tracheal scaffolds and compared the results to scaffolds produced under normal atmospheric pressures. The principal outcome measures were the reduction in time (9 days to prepare the scaffold) followed by a reduction in residual DNA levels (DC no-vac: 137.8±48.82 ng/mg vs. DC vac 36.83±18.45 ng/mg, p<0.05.). Our approach did not impact on the collagen or glycosaminoglycan content or on the biomechanical properties of the scaffolds. We applied the vacuum technology to human tracheae, which, when implanted in vivo showed no significant adverse immunological response. The addition of a vacuum to a conventional decellularization protocol significantly reduces production time, whilst providing a suitable scaffold. This increases clinical utility and lowers production costs. To our knowledge this is the first time that vacuum assisted decellularization has been explored. Copyright © 2015 John Wiley & Sons, Ltd. Copyright © 2015 John Wiley & Sons, Ltd.
Perone, Nicola
2018-04-25
To describe an innovative electronically-controlled vacuum extractor (VE) in detail and to illustrate its performance characteristics, as observed in a laboratory study. Thirty simulated, vacuum-assisted deliveries. (1) The ability to measure in real-time of the pull applied and to sound an alert, when the traction approaches the negative pressure under the cup, to prevent its detachment. (2) The recording and printing of a graphic representation of the pull applied (vacuum delivery graph). (3) The emission of a warning signal when the 15-min time limit of continuous cup application on the fetal scalp, is reached. No cup detachment occurred in any of the 15 vacuum-assisted deliveries, in which traction was kept below the adhesive force of the cup [44 lb (20 kg)], except in three cases, due to loss of negative pressure. In the remaining 15 tests, in which traction was greater than the adhesive force of the cup, "pull-offs" inevitably occurred. Furthermore, upon reaching the 15-min time limit of continuous cup application on the fetal cephalic model, a warning signal was emitted, as programmed. Conclusions We demonstrated that the electronically-controlled VE, with its distinctive pull-sensing handle, performs suitably for its intended purposes. The ability of the modernized device to decrease the incidence of cup detachment, secondary to the inadvertent application of excessive traction, may result in considerable safety, medico-legal and didactic advantages.
Boyum, James H; Atwell, Thomas D; Wall, Darci J; Mansfield, Aaron S; Kerr, Sarah E; Gunderson, Tina M; Rumilla, Kandelaria M; Weisbrod, Adam J; Kurup, A Nicholas
2018-05-17
To analyze a large volume of image-guided liver mass biopsies to assess for an increased incidence of major hemorrhage after aggressive liver mass sampling, and to determine if coaxial technique reduces major hemorrhage rate. Patients who underwent image-guided liver mass biopsy over a 15-year period (December 7, 2001-September 22, 2016) were retrospectively identified. An aggressive biopsy was defined as a biopsy event in which ≥ 4 core needle passes were performed. Association of major hemorrhage after aggressive liver mass biopsy and other potential risk factors of interest were assessed using logistic regression analysis. For the subset of aggressive biopsies, Fisher's exact test was used to compare the incidence of major hemorrhage using coaxial versus noncoaxial techniques. Aggressive biopsies constituted 11.6% of biopsy events (N =579/5011). The incidence of major hemorrhage with <4 passes was 0.4% (N =18/4432) and with ≥4 passes 1.2% (N =6/579). In univariable models, aggressive biopsy was significantly associated with major hemorrhage (OR 3.0, 95% CI 1.16-6.92, p =0.025). After adjusting for gender and platelet count, the association was not significant at the p =0.05 level (OR 2.58, 95% CI 0.927-6.24, p =0.067). The rate of major hemorrhage in the coaxial biopsy technique group was 1.4% (N =3/209) compared to 1.1% (N =4/370) in the noncoaxial biopsy technique group, which was not a significant difference (p =0.707). Although aggressive image-guided liver mass biopsies had an increased incidence of major hemorrhage, the overall risk of bleeding remained low. The benefit of such biopsies will almost certainly outweigh the risk in most patients.
Bilateral Wilms' tumor with anaplasia: lessons from the National Wilms' Tumor Study.
Hamilton, Thomas E; Green, Daniel M; Perlman, Elizabeth J; Argani, Pedram; Grundy, Paul; Ritchey, Michael L; Shamberger, Robert C
2006-10-01
The purpose of this study was to evaluate whether initial diagnostic technique influenced the ability to identify anaplastic histology, to determine the time interval to diagnosis of anaplasia, and to delineate the incidence of discordant pathology in bilateral Wilms' tumor. We hypothesized that delay in diagnosis of anaplasia could affect time to appropriate surgery and intensive multimodality therapy. One hundred eight-nine children were enrolled in the fourth National Wilms' Tumor Study with synchronous bilateral tumors, 27 of whom were eventually shown to have anaplastic histology. Initial diagnostic technique, time interval to diagnosis of anaplasia, and the incidence of discordant pathology were determined. Anaplasia was identified in 0 of 7 tumors by core needle biopsy, 3 of 9 tumors by open wedge biopsy, and in 7 of 9 cases by partial or complete nephrectomy. The mean duration of first chemotherapy regimen (DD or EE) was 20, 39, and 36 weeks, respectively, before anaplasia was identified at second surgery. Discordant pathology between bilateral tumors was identified on final tissue diagnosis in 20 patients. Only 4 patients had anaplastic tumors in both kidneys. Core needle biopsy did not identify anaplasia in 7 of 7 children. Open biopsy or partial/complete nephrectomy identified anaplasia at initial diagnostic procedure in 10 of 18 children. Twenty of 24 patients at final tissue diagnosis had discordant pathology between the 2 kidneys. Earlier interval incisional biopsy or resection may identify anaplastic histology and limit the duration of chemotherapy targeted to favorable histology for children with bilateral Wilms' tumor and anaplasia.
Evans, Andrew J; Delahunt, Brett; Srigley, John R
2015-03-01
Percutaneous needle core biopsy has become acceptable for classifying renal tumours and guiding patient management in the setting of an incidentally-detected small renal mass (SRM), defined as an asymptomatic, non-palpable mass <4cm in maximum dimension. Long-held concerns preventing the incorporation of biopsies into routine patient care, including the perception of poor diagnostic yield and risks of complications such as bleeding or biopsy tract seeding, have largely been disproven. While needle biopsies for SRMs have traditionally been performed in academic centres, pathologists based in non-academic centres can expect to encounter these specimens as urologists and/or interventional radiologist trainees complete their training programs and begin work in non-academic centres. This review covers the rationale for performing these biopsies, the expected diagnostic yield, relevant differential diagnoses and an approach to classifying SRMs based on limited samples as well as the use of immunohistochemical (IHC) staining panels to aid in this process. There is also an undeniable learning curve for pathologists faced with reporting these biopsies and a number of issues and potential pitfalls attributable to sampling must be kept in mind by pathologists and clinicians alike. Copyright © 2015 Elsevier Inc. All rights reserved.
40 CFR 35.6215 - Eligibility for Core Program Cooperative Agreements.
Code of Federal Regulations, 2013 CFR
2013-07-01
... GRANTS AND OTHER FEDERAL ASSISTANCE STATE AND LOCAL ASSISTANCE Cooperative Agreements and Superfund State Contracts for Superfund Response Actions Core Program Cooperative Agreements § 35.6215 Eligibility for Core...
40 CFR 35.6215 - Eligibility for Core Program Cooperative Agreements.
Code of Federal Regulations, 2012 CFR
2012-07-01
... GRANTS AND OTHER FEDERAL ASSISTANCE STATE AND LOCAL ASSISTANCE Cooperative Agreements and Superfund State Contracts for Superfund Response Actions Core Program Cooperative Agreements § 35.6215 Eligibility for Core...
40 CFR 35.6215 - Eligibility for Core Program Cooperative Agreements.
Code of Federal Regulations, 2014 CFR
2014-07-01
... GRANTS AND OTHER FEDERAL ASSISTANCE STATE AND LOCAL ASSISTANCE Cooperative Agreements and Superfund State Contracts for Superfund Response Actions Core Program Cooperative Agreements § 35.6215 Eligibility for Core...
Use of individual containers for prostate biopsy samples: Do we gain diagnostic performance?
Panach-Navarrete, J; García-Morata, F; Valls-González, L; Martínez-Jabaloyas, J M
2016-05-01
Prostate cores from transrectal biopsies are usually sent in separate vials for pathological processing. Although this is a common practice, there are controversial studies on its usefulness. We wanted to compare the rate of prostate cancer diagnosis between processing samples in 2 containers and processing them in individual containers to see if there are differences. Our secondary objective was to check the rate of diagnosis of various tumour subtypes in each of the 2 groups. A retrospective observational study was conducted of 2,601 cases of prostate biopsies. Ten cores were extracted in each biopsy. We divided the sample into 2 groups: biopsies sent in 2 containers to the department of pathology (left and right lobes) or sent in 10 (one for each cylinder), according to the different criteria used in our centre in the past. We then classified the cases according to the absence of neoplasia, insignificant tumour (involvement of just 1 cylinder, <5%, Gleason score<7), Gleason 6 or Gleason≥7. A bivariate statistical analysis was performed using the chi-squared test. A total of 1,777 participants were included in the 2-container group, and 824 were included in the 10-container group. We diagnosed a rate of 32.4% of cancers in the 2-container group and 40% in the 10-container group, a difference that was statistically significant (P<.001). The insignificant carcinomas were diagnosed more often in the 2-container group than in the 10-container group (6.4% vs. 4.3%, respectively; P=.03). Samples with a Gleason score of 6 were diagnosed more often in the 10-container group than in the 2-container group (11.9% vs. 8.1%, respectively; P=.002). The same occurred with the Gleason score≥7 (23.8% in the 10-container group vs. 17.9% in the 2-container group; P<.001). We diagnosed more prostate cancers when sending biopsied cores in individual containers. Once the procedure was conducted, we also observed in our series a reduction in the diagnoses of insignificant carcinoma to the detriment of an increased diagnosis of not insignificant carcinomas. Copyright © 2015 AEU. Publicado por Elsevier España, S.L.U. All rights reserved.
Legisi, Lorena; DeSa, Elise; Qureshi, M Nasar
2016-12-01
Prostate cancer is the most common cancer diagnosed in men in developed countries. Using molecular testing may help to improve outcomes in this clinically challenging group. Since 2011, the Prostate Core Mitomic Test (PCMT), which quantifies a 3.4-kb mitochondrial DNA deletion strongly associated with prostate cancer, has been used by more than 50 urology practices accessing pathology services through our laboratory in New Jersey. However, the use of a molecular test can only be beneficial if it affects patient management and improves outcomes. To determine whether repeated biopsy decision-making was affected in a quantifiable manner through the adjunct use of molecular testing with the PCMT. In this observational study we conducted 2 independent, structured query language database queries of our patient records at our laboratory, QDx Pathology Services, in Cranford, NJ. Query 1 included all men who had a negative prostate biopsy and a negative PCMT between February 1, 2011, and June 30, 2013. Men with a previous diagnosis of cancer were excluded. Query 2 included all men who had a negative prostate biopsy and a repeated biopsy between February 1, 2011, and September 30, 2013. The data exported for each query included the unique specimen number for an index biopsy, the interval between biopsies where present, the unique specimen number for a follow-up biopsy where present, histopathology for all biopsies, the biopsy procedure dates, the patient's date of birth, and the PCMT result when utilized. The patient rebiopsy rates and intervals were compared between the patients who were using PCMT and those who were not to assess whether the adjunct use of the PCMT impacted the rebiopsy decision-making process. Query 1 identified 644 men who had a negative biopsy and a negative PCMT result within the study period. Query 2 identified 823 men with a repeat biopsy after the initial negative index biopsy within the study period. Of these men, 132 had PCMT to inform their care. This patient population of 1467 men originated from US-based clinical urology practices. Evaluation of the impact on physician behavior demonstrated a general trend toward the earlier detection of prostate cancer on repeat biopsy by an average of 2.5 months and a coincident increase in cancer detection rates for urologists using the deletion assay in their rebiopsy decision-making process. Importantly, this trend was only observed when men with atypical small acinar proliferation (ASAP) on index biopsy were not considered. In the 644 men with a negative PCMT result, only 35 (5.4%) were subjected to a follow-up biopsy, with 5 (14.3%) of the 35 men identified as having cancer. Finally, the cohort of 132 men who had PCMT and repeat biopsy was compared with the published data supporting PCMT's ability to predict rebiopsy outcome. The key metrics of sensitivity and negative predictive value were comparable and within the 95% confidence intervals of the reported work. Molecular tests, such as the PCMT, are useful in addressing the sampling error of prostate needle biopsy and providing additional evidence to inform the clinical uncertainty regarding initial negative prostate biopsy when ASAP is not present. Longitudinal monitoring of clinical impact indicators provides the necessary inputs to better allocation of healthcare resources in the short- and long-term.
Upgrading the Gleason Score in Extended Prostate Biopsy: Implications for Treatment Choice
DOE Office of Scientific and Technical Information (OSTI.GOV)
Moreira Leite, Katia Ramos; Laboratory of Surgical and Molecular Pathology - Hospital Sirio Libanes, Sao Paulo; Camara-Lopes, Luiz H.A.
2009-02-01
Purpose: To determine the incidence of overestimation of Gleason score (GS) in extended prostate biopsy, and consequently circumventing unnecessary aggressive treatment. Methods and Materials: This is a retrospective study of 464 patients who underwent prostate biopsy and radical prostatectomy between January 2001 and November 2007. The GS from biopsy and radical prostatectomy were compared. The incidence of overestimation of GS in biopsies and tumor volume were studied. Multivariate analysis was applied to find parameters that predict upgrading the GS in prostate biopsy. Results: The exact agreement of GS between prostate biopsy and radical prostatectomy occurred in 56.9% of cases. Inmore » 29.1% cases it was underestimated, and it was overestimated in 14%. One hundred and six (22.8%) patients received a diagnosis of high GS (8, 9, or 10) in a prostate biopsy. In 29.2% of cases, the definitive Gleason Score was 7 or lower. In cases in which GS was overestimated in the biopsy, tumors were significantly smaller. In multivariate analysis, the total percentage of tumor was the only independent factor in overestimation of GS. Tumors occupying less than 33% of cores had a 5.6-fold greater chance of being overestimated. Conclusion: In the extended biopsy era and after the International Society of Urological Pathology consensus on GS, almost one third of tumors considered to have high GS at the biopsy may be intermediate-risk cancers. In that condition, tumors are smaller in biopsy. This should be remembered by professionals involved with prostate cancer to avoid overtreatment and undesirable side effects.« less
Equy, Véronique; David-Tchouda, Sandra; Dreyfus, Michel; Riethmuller, Didier; Vendittelli, Françoise; Cabaud, Victoire; Langer, Bruno; Margier, Jennifer; Bosson, Jean-Luc; Schaal, Jean-Patrick
2015-12-15
Assisted vaginal delivery by vacuum extraction is frequent. Metallic resterilizible metallic vacuum cups have been routinely used in France. In the last few years a new disposable semi-soft vacuum extraction cup, the iCup, has been introduced. Our objective was to compare maternal and new-born outcomes between this disposable cup and the commonly used Drapier-Faure metallic cup. This was a multicenter prospective randomized controlled open clinical trial performed in the maternity units of five university hospitals and one community hospital in France from October 2009 to February 2013. We included consecutive eligible women with a singleton gestation of at least 37 weeks who required vacuum assisted delivery. Women were randomized to vacuum extraction using the iCup or usual Drapier-Faure metallic cup. The primary outcome was a composite criterion including both the risk of cup dysfunction and the most frequent maternal and neonatal harms: the use of other instruments after attempted vacuum extraction, caesarean section after attempted vacuum extraction, three detachments of the cup, caput succedaneum, cephalohaematoma, episiotomy and perineal tears. 335 women were randomized to the disposable cup and 333 to extraction using the metallic cup. There was no significant difference between the two groups for the primary outcome. However, failed instrumental delivery was more frequent in the disposable cup group, mainly due to detachment: 35.6 % vs 7.1 %, p < 0.0001. Conversely, perineal tears were more frequent in the metallic cup group, especially third or fourth grade perineal tears: 1.7 % versus 5.0 %, p = 0.003. There were no significant differences between the two groups concerning post-partum haemorrhage, transfer to a neonatal intensive care unit (NICU) or serious adverse events. While the disposable cup had more detachments and extraction failures than the standard metallic cup, this innovative disposable device had the advantage of fewer perineal injuries. www.clinicaltrials.gov : NCT01058200 on Jan. 27 2010.
Abudayyeh, Suhaib; Hoffman, Jill; El-Zimaity, Hala T.; Graham, David Y.
2010-01-01
Background Endoscopic biopsy forceps differ in the size and shape of the biopsy cup and the presence or absence of a needle. Methods We compared 4 different “large cup” forceps (3 with needles designed for 2.8 mm biopsy channels. A gastric antral and corpus biopsy were obtained with each. Parameters examined included: weight (mg), length (mm), orientation (poor, good), intactness (1, 2, or 3 pieces), depth (superficial, above muscularis mucosae, included muscularis mucosae), crush artifact (yes, no), and overall adequacy (inadequate, suboptimal, adequate). Results 24 patients were enrolled (191 biopsies). The median length was approximately 5 mm (range 1.1 to 8.2 mm). Histologically inadequate specimens were present in 4% with the forceps without needle compared to 16% of those with needles (P = 0.061) and there were significantly fewer specimens in 3 or more pieces than did the forceps with needles 2.1% vs. 12..6% (P<0.05). Conclusions Current alligator style forceps provide a high proportion of acceptable specimens with only minor differences between brands. Forceps from one source were least preferred by endoscopy assistants and had the highest rates of inadequate biopsies and biopsies with crush artifact. Forceps without needles provide histologically acceptable samples slightly more frequently than those with needles. PMID:18799373
Abudayyeh, S; Hoffman, J; El-Zimaity, H T; Graham, D Y
2009-05-01
Endoscopic biopsy forceps differ in the size and shape of the biopsy cup and the presence or absence of a needle. We compared four different "large cup" forceps (three with needles) designed for 2.8mm biopsy channels. A gastric antral and corpus biopsy were obtained with each. Parameters examined included: weight (mg), length (mm), orientation (poor, good), intactness (1, 2, or 3 pieces), depth (superficial, above muscularis mucosae, included muscularis mucosae), crush artefact (yes, no), and overall adequacy (inadequate, suboptimal, adequate). Twenty-four patients were enrolled (191 biopsies). The median length was approximately 5mm (range 1.1-8.2mm). Histologically inadequate specimens were present in 4% with the forceps without needle compared to 16% of those with needles (P=0.061) and there were significantly fewer specimens in three or more pieces than did the forceps with needles 2.1% vs. 12.6% (P<0.05). Current alligator style forceps provide a high proportion of acceptable specimens with only minor differences between brands. Forceps from one source were least preferred by endoscopy assistants and had the highest rates of inadequate biopsies and biopsies with crush artefact. Forceps without needles provide histologically acceptable samples slightly more frequently than those with needles.
Determinants of complications after multiple transrectal core biopsies of the prostate.
Norberg, M; Holmberg, L; Häggman, M; Magnusson, A
1996-01-01
Transrectal ultrasound-guided biopsies of the prostate were performed on 347 consecutive men. All patients were given prophylactic antibiotics. The first 199 patients received 400 mg norfloxacin immediately after the biopsies were performed and 400 mg the same evening. The second group of 148 patients received 400 mg of norfloxacin 1 h before the examination followed by five doses administered twice daily. A total of 15 major complications were noted. In the first group the complication rate was 6.5% and in the second group 1.4%. The different regimes of prophylactic antibiotic treatment were the only parameters shown to have a statistically significant impact on the complication rate. The number of complications decreased, but were not eliminated, when prophylactic treatment with norfloxacin was given before the biopsies were taken and continued for a total of 3 days.
Displaced epithelium after liposuction for gynecomastia.
McLaughlin, Cristina S; Petrey, Chris; Grant, Shawn; Ransdell, Jill S; Reynolds, Carol
2011-08-01
The authors describe the case of a 36-year-old man with gynecomastia who was previously treated with liposuction of the breast for cosmetic purposes. Histologic examination of a subsequent excisional biopsy revealed nests of displaced epithelial cells in adipose tissue. Epithelial cell displacement is a well-known risk of core needle biopsies and fine-needle aspirations of breast lesions. However, to the authors' knowledge, epithelial displacement in gynecomastia after liposuction, mimicking invasive ductal carcinoma, has not previously been reported.
Metintas, Muzaffer; Yildirim, Huseyin; Kaya, Tamer; Ak, Guntulu; Dundar, Emine; Ozkan, Ragip; Metintas, Selma
2016-01-01
Image-guided pleural biopsies, both using ultrasound (US) or computed tomography (CT), are important in the diagnosis of pleural disease. However, no consensus exists regarding which biopsy needles are appropriate for specific procedures. In this randomized, prospective study, we aimed to compare CT scan-guided pleural biopsy using an Abrams' needle (CT-ANPB) with US-assisted pleural biopsy using a cutting needle (US-CNPB) with respect to both diagnostic yield and safety. Between February 2009 and April 2013, 150 patients with exudative pleural effusion who could not be diagnosed by cytological analysis were included in the study. The patients were randomized into either the US-CNPB group or the CT-ANPB group. The two groups were compared in terms of diagnostic sensitivity and complications. Of the 150 patients enrolled in this study, 45 were diagnosed with malignant mesothelioma, 46 were diagnosed with metastatic pleural disease, 18 were diagnosed with pleural tuberculosis, 34 were diagnosed with benign pleural disease, and 7 were lost to follow-up. In the US-CNPB group, the diagnostic sensitivity was 66.7%, compared with 82.4% in the CT-ANPB group; the difference between the two groups was statistically significant (p = 0.029). The sensitivity of CT-ANPB increased to 93.7% for patients with a pleural thickness ≥1 cm. The complication rates were low and acceptable. The first diagnostic intervention that should be preferred in patients with pleural effusion and associated pleural thickening on a CT scan is CT-ANPB. US-CNPB should be used primarily in cases for which only pleural thickening but no pleural effusion is noted. © 2016 S. Karger AG, Basel.
Luong, Benjamin; Danforth, Teresa; Visnjevac, Ognjen; Suraf, Margaret; Duff, Michael; Chevli, K Kent
2015-03-01
To evaluate the hospitalization rates in 2 pre-prostate biopsy antibiotic protocols. Two prebiopsy protocols were compared. CiproAlone required ciprofloxacin 500 mg twice daily starting 1 day before biopsy and continuing for 3 days after biopsy (4 days total). Diabetic patients were prescribed ciprofloxacin for 4 days after biopsy. CiproCeft required 1 dose of oral ciprofloxacin 500 mg 1 hour before the biopsy and ceftriaxone 1 g intramuscular at the time of the biopsy. Hospitalization rates between the CiproAlone vs CiproCeft protocols were examined. A total of 4134 biopsies were identified-2093 in the CiproAlone cohort and 2041 in the CiproCeft cohort. The post-prostate biopsy infection hospitalization rate was 0.6% (14 patients) in the CiproAlone group vs 0.0% (0 patients) in the CiproCeft group (P <.0001). Of the patients hospitalized, 12 fit systemic inflammatory response syndrome (SIRS) criteria. Eight of 14 hospitalized patients fit the sepsis (SIRS and source of infection) criteria. Positive cultures (urine and/or blood) resulted from 71% (n = 10) of hospitalized patients. Antibiotic resistance was analyzed. Diabetes mellitus was associated with hospitalization after prostate biopsy (P = .01) in our population, but there was no difference between the 2 groups in the rates of diabetes mellitus (P = .46). Patient age, prostate-specific antigen level, number of biopsy cores obtained, race, and previous antibiotics exposure were not found to be independent predictors of post-transrectal ultrasonography biopsy hospitalization for infection using a multivariate regression analysis. A prophylactic prebiopsy protocol including 2 classes of antibiotics, single-dose ciprofloxacin, and single-dose intramuscular ceftriaxone reduced post-transrectal ultrasonography biopsy rates of hospitalizations compared to oral ciprofloxacin alone. Copyright © 2015 Elsevier Inc. All rights reserved.
Flow and Compaction During the Vacuum Assisted Resin Transfer Molding Process
NASA Technical Reports Server (NTRS)
Grimsley, Brian W.; Hubert, Pascal; Song, Xiao-Lan; Cano, Roberto J.; Loos, Alfred C.; Pipes, R. Byron
2001-01-01
The flow of an epoxy resin and compaction behavior of carbon fiber preform during vacuum- assisted resin transfer molding (VARTM) infiltration was measured using an instrumented tool. Composite panels were fabricated by the VARTM process using SAERTEX(R)2 multi-axial non- crimp carbon fiber fabric and the A.T.A.R.D. SI-ZG-5A epoxy resin. Resin pressure and preform thickness variation was measured during infiltration. The effects of the resin on the compaction behavior of the preform were measured. The local preform compaction during the infiltration is a combination of wetting and spring-back deformations. Flow front position computed by the 3DINFIL model was compared with the experimental data.
Percentage of Positive Biopsy Cores: A Better Risk Stratification Model for Prostate Cancer?
DOE Office of Scientific and Technical Information (OSTI.GOV)
Huang Jiayi; Vicini, Frank A.; Williams, Scott G.
2012-07-15
Purpose: To assess the prognostic value of the percentage of positive biopsy cores (PPC) and perineural invasion in predicting the clinical outcomes after radiotherapy (RT) for prostate cancer and to explore the possibilities to improve on existing risk-stratification models. Methods and Materials: Between 1993 and 2004, 1,056 patients with clinical Stage T1c-T3N0M0 prostate cancer, who had four or more biopsy cores sampled and complete biopsy core data available, were treated with external beam RT, with or without a high-dose-rate brachytherapy boost at William Beaumont Hospital. The median follow-up was 7.6 years. Multivariate Cox regression analysis was performed with PPC, Gleasonmore » score, pretreatment prostate-specific antigen, T stage, PNI, radiation dose, androgen deprivation, age, prostate-specific antigen frequency, and follow-up duration. A new risk stratification (PPC classification) was empirically devised to incorporate PPC and replace the T stage. Results: On multivariate Cox regression analysis, the PPC was an independent predictor of distant metastasis, cause-specific survival, and overall survival (all p < .05). A PPC >50% was associated with significantly greater distant metastasis (hazard ratio, 4.01; 95% confidence interval, 1.86-8.61), and its independent predictive value remained significant with or without androgen deprivation therapy (all p < .05). In contrast, PNI and T stage were only predictive for locoregional recurrence. Combining the PPC ({<=}50% vs. >50%) with National Comprehensive Cancer Network risk stratification demonstrated added prognostic value of distant metastasis for the intermediate-risk (hazard ratio, 5.44; 95% confidence interval, 1.78-16.6) and high-risk (hazard ratio, 4.39; 95% confidence interval, 1.70-11.3) groups, regardless of the use of androgen deprivation and high-dose RT (all p < .05). The proposed PPC classification appears to provide improved stratification of the clinical outcomes relative to the National Comprehensive Cancer Network classification. Conclusions: The PPC is an independent and powerful predictor of clinical outcomes of prostate cancer after RT. A risk model replacing T stage with the PPC to reduce subjectivity demonstrated potentially improved stratification.« less
Towards high-capacity fibre-optic communications at the speed of light in vacuum
NASA Astrophysics Data System (ADS)
Poletti, F.; Wheeler, N. V.; Petrovich, M. N.; Baddela, N.; Numkam Fokoua, E.; Hayes, J. R.; Gray, D. R.; Li, Z.; Slavík, R.; Richardson, D. J.
2013-04-01
Wide-bandwidth signal transmission with low latency is emerging as a key requirement in a number of applications, including the development of future exaflop-scale supercomputers, financial algorithmic trading and cloud computing. Optical fibres provide unsurpassed transmission bandwidth, but light propagates 31% slower in a silica glass fibre than in vacuum, thus compromising latency. Air guidance in hollow-core fibres can reduce fibre latency very significantly. However, state-of-the-art technology cannot achieve the combined values of loss, bandwidth and mode-coupling characteristics required for high-capacity data transmission. Here, we report a fundamentally improved hollow-core photonic-bandgap fibre that provides a record combination of low loss (3.5 dB km-1) and wide bandwidth (160 nm), and use it to transmit 37 × 40 Gbit s-1 channels at a 1.54 µs km-1 faster speed than in a conventional fibre. This represents the first experimental demonstration of fibre-based wavelength division multiplexed data transmission at close to (99.7%) the speed of light in vacuum.
Mintziras, Ioannis; Miligkos, Michael; Bartsch, Detlef Klaus
2016-08-01
The aim of this study was to evaluate the efficacy of vacuum-assisted closure therapy in patients with open abdomen due to secondary peritonitis and to identify possible risk factors of fistula formation. The hospital OPS-database (time period 2005-2014) was searched to identify patients treated with an open abdomen due to secondary peritonitis, who underwent vacuum-assisted closure therapy. Medical records were retrospectively analyzed for patients' characteristics, cause of peritonitis, duration of vacuum therapy, number of relaparotomies, fascial closure rates, and risk factors of fistula formation. Forty-three patients (19 male, 24 female) with a median age of 65 years (range 24-90 years) were identified. The major cause of secondary peritonitis was anastomotic leakage after intestinal anastomosis or bowel perforation, the median APACHE II score was 11. Median duration of VAC treatment was 12 days (range 3-88 days). Twenty of 43 (47 %) patients died from septic complications. Delayed fascial closure was obtained by suturing in 20 of 43 patients (47 %). Overall 16 of 43 (37 %) patients developed enteroatmospheric fistulas. Re-explorations after starting VAC treatment and duration of VAC therapy were significantly associated with the occurrence of enteroatmospheric fistulas (p < 0.001). ROC curve analysis determined the optimal duration of VAC therapy to reduce the risk of fistula formation at 13 days. Long-term VAC treatment of patients with an open abdomen due to secondary peritonitis results in a relatively low fascial closure rate and a high risk of fistula formation.
Ultrasonic Spray Drying vs High Vacuum and Microwaves Technology for Blueberries
NASA Astrophysics Data System (ADS)
Candia-Muñoz, N.; Ramirez-Bunster, M.; Vargas-Hernández, Y.; Gaete-Garretón, L.
Interest in high quality foods: good taste and a high content of nutrients with healthy beneficial effects are increasing. Fruits have good properties but, they are lost because the oxidation process, additionally, for different reasons a 40% of harvested fruit are lost. To conserve the fruit properties an ultrasonic assisted spray dryer was developed and tested, comparing its results with microwave-vacuum drying technology. Results did shown taste, color, smell, particle shape and size distribution better than the conventional one. The antioxidants conservation were quite good except in the anthocyanins, in which the microwave and vacuum technology shown best results.
Martini, Alberto; Gupta, Akriti; Lewis, Sara C; Cumarasamy, Shivaram; Haines, Kenneth G; Briganti, Alberto; Montorsi, Francesco; Tewari, Ashutosh K
2018-04-19
To develop a nomogram for predicting side-specific extracapsular extension (ECE) for planning nerve-sparing radical prostatectomy. We retrospectively analysed data from 561 patients who underwent robot-assisted radical prostatectomy between February 2014 and October 2015. To develop a side-specific predictive model, we considered the prostatic lobes separately. Four variables were included: prostate-specific antigen; highest ipsilateral biopsy Gleason grade; highest ipsilateral percentage core involvement; and ECE on multiparametric magnetic resonance imaging (mpMRI). A multivariable logistic regression analysis was fitted to predict side-specific ECE. A nomogram was built based on the coefficients of the logit function. Internal validation was performed using 'leave-one-out' cross-validation. Calibration was graphically investigated. The decision curve analysis was used to evaluate the net clinical benefit. The study population consisted of 829 side-specific cases, after excluding negative biopsy observations (n = 293). ECE was reported on mpMRI and final pathology in 115 (14%) and 142 (17.1%) cases, respectively. Among these, mpMRI was able to predict ECE correctly in 57 (40.1%) cases. All variables in the model except highest percentage core involvement were predictors of ECE (all P ≤ 0.006). All variables were considered for inclusion in the nomogram. After internal validation, the area under the curve was 82.11%. The model demonstrated excellent calibration and improved clinical risk prediction, especially when compared with relying on mpMRI prediction of ECE alone. When retrospectively applying the nomogram-derived probability, using a 20% threshold for performing nerve-sparing, nine out of 14 positive surgical margins (PSMs) at the site of ECE resulted above the threshold. We developed an easy-to-use model for the prediction of side-specific ECE, and hope it serves as a tool for planning nerve-sparing radical prostatectomy and in the reduction of PSM in future series. © 2018 The Authors BJU International © 2018 BJU International Published by John Wiley & Sons Ltd.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Stattaus, Joerg, E-mail: joerg.stattaus@uni-due.de; Kuehl, Hilmar; Ladd, Susanne
2007-09-15
Purpose. Our study aimed to determine the visibility of small liver lesions during CT-guided biopsy and to assess the influence of lesion visibility on biopsy results. Material and Methods. Fifty patients underwent CT-guided core biopsy of small focal liver lesions (maximum diameter, 3 cm); 38 biopsies were performed using noncontrast CT, and the remaining 12 were contrast-enhanced. Visibility of all lesions was graded on a 4-point-scale (0 = not visible, 1 = poorly visible, 2 = sufficiently visible, 3 = excellently visible) before and during biopsy (with the needle placed adjacent to and within the target lesion). Results. Forty-three biopsiesmore » (86%) yielded diagnostic results, and seven biopsies were false-negative. In noncontrast biopsies, the rate of insufficiently visualized lesions (grades 0-1) increased significantly during the procedure, from 10.5% to 44.7%, due to needle artifacts. This resulted in more (17.6%) false-negative biopsy results compared to lesions with good visualization (4.8%), although this difference lacks statistical significance. Visualization impairment appeared more often with an intercostal or subcostal vs. an epigastric access and with a subcapsular vs. a central lesion location, respectively. With contrast-enhanced biopsy the visibility of hepatic lesions was only temporarily improved, with a risk of complete obscuration in the late phase. Conclusion. In conclusion, visibility of small liver lesions diminished significantly during CT-guided biopsy due to needle artifacts, with a fourfold increased rate of insufficiently visualized lesions and of false-negative histological results. Contrast enhancement did not reveal better results.« less
Antonio Sainz, José; Borrero, Carlota; Aquise, Adriana; García-Mejido, José Antonio; Gutierrez, Laura; Fernández-Palacín, Ana
2016-10-01
Our aim is to evaluate the capacity of intrapartum translabial ultrasound (ITU) with pushing in the prediction of difficulty of fetal extraction in vacuum assisted deliveries. Prospective, observational study performed (2/2015-8/2015) on 75 nulliparous women, ≥37 weeks with singleton pregnancies at full dilatation who had ITU-with-pushing performed, previous to vacuum-placement for fetal extraction. Working on the translabial sagittal-plane, we assessed: Angle-Progression (AoP), Progression-Distance (PD) and Head-Direction (HD); in the axial plane we evaluated: Midline-Angle (MLA) and Head-Perineum-Distance (HPD). Vacuum extractions were classified as easy-difficulty (ED) (≤3 vacuum-pulls), difficult-unsuccessful (DD) (>3 vacuum-pulls). We did not assess occipito-posterior-presentations. Seventy nulliparous were studied (44-ED,26-DD). We observed no differences in obstetric, neonatal or intrapartum characteristics between the two study groups, with the following exceptions: newborn weight (3272 ± 438 g versus 3540 ± 372 g; p = 0.011) and number of vacuum-pulls (1.4-ED-vs-4.4-DD; p < 0.0005). AoP-pushing was 143.9° ± 14.6° in ED and 115.1°± 12.9° in DD (p < 0.0005); Head-Up was 79.5% versus 38.4% (p < 0.0005); PD-Pushing was 42.7 ± 11.3 mm versus 30.4 ± 9.8 mm (p < 0.0005); MLA-Pushing was 27.6°± 26.6° versus 57.5°±26.5°(p=0.025); HPD-Pushing was 40.8 ± 10.0 mm versus 47.4 ± 10.9 mm (p = 0.039). We identified that the presence of an AoP-Pushing > 128° predicts an Easy-Vacuum-Delivery (≤3 Vacuum-Pulls) in >85% of cases (Sen 80%-FPR 9.3%).
Technical specification for vacuum systems
DOE Office of Scientific and Technical Information (OSTI.GOV)
Khaw, J.
The vacuum systems at the Stanford Linear Accelerator Center (SLAC) are primarily of all-metal construction and operate at pressures from 10/sup -5/ to 10/sup -11/ Torr. The primary gas loads during operation result from thermal desorption and beam-induced desorption from the vacuum chamber walls. These desorption rates can be extremely high in the case of hydrocarbons and other contaminants. These specifications place a major emphasis on eliminating contamination sources. The specifications and procedures have been written to insure the cleanliness and vacuum integrity of all SLAC vacuum systems, and to assist personnel involved with SLAC vacuum systems in choosing andmore » designing components that are compatible with existing systems and meet the quality and reliability of SLAC vacuum standards. The specification includes requirements on design, procurement, fabrication, chemical cleaning, clean room practices, welding and brazing, helium leak testing, residual gas analyzer testing, bakeout, venting, and pumpdown. Also appended are specifications regarding acceptable vendors, isopropyl alcohol, bakeable valve cleaning procedure, mechanical engineering safety inspection, notes on synchrotron radiation, and specifications of numerous individual components. (LEW)« less
Chemical changes exhibited by latent fingerprints after exposure to vacuum conditions.
Bright, Nicholas J; Willson, Terry R; Driscoll, Daniel J; Reddy, Subrayal M; Webb, Roger P; Bleay, Stephen; Ward, Neil I; Kirkby, Karen J; Bailey, Melanie J
2013-07-10
The effect of vacuum exposure on latent fingerprint chemistry has been evaluated. Fingerprints were analysed using a quartz crystal microbalance to measure changes in mass, gas chromatography mass spectrometry to measure changes in lipid composition and attenuated total reflection Fourier transform infrared spectroscopy (ATR-FTIR) to determine changes in the content of water, fatty acids and their esters after exposure to vacuum. The results are compared with samples aged under ambient conditions. It was found that fingerprints lose around 26% of their mass when exposed to vacuum conditions, equivalent to around 5 weeks ageing under ambient conditions. Further exposure to vacuum causes a significant reduction in the lipid composition of a fingerprint, in particular with the loss of tetradecanoic and pentadecanoic acid, that was not observed in ambient aged samples. There are therefore implications for sequence in which fingerprint development procedures (for example vacuum metal deposition) are carried out, as well as the use of vacuum based methods such as secondary ion mass spectrometry (SIMS) and matrix-assisted laser desorption ionisation (MALDI) in the study of fingerprint chemistry. Copyright © 2013. Published by Elsevier Ireland Ltd.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Zorn, Kevin C.; Capitanio, Umberto; Jeldres, Claudio
2009-04-01
Purpose: The Partin tables represent one of the most widely used prostate cancer staging tools for seminal vesicle invasion (SVI) prediction. Recently, Gallina et al. reported a novel staging tool for the prediction of SVI that further incorporated the use of the percentage of positive biopsy cores. We performed an external validation of the Gallina et al. nomogram and the 2007 Partin tables in a large, multi-institutional North American cohort of men treated with robotic-assisted radical prostatectomy. Methods and Materials: Clinical and pathologic data were prospectively gathered from 2,606 patients treated with robotic-assisted radical prostatectomy at one of four Northmore » American robotic referral centers between 2002 and 2007. Discrimination was quantified with the area under the receiver operating characteristics curve. The calibration compared the predicted and observed SVI rates throughout the entire range of predictions. Results: At robotic-assisted radical prostatectomy, SVI was recorded in 4.2% of patients. The discriminant properties of the Gallina et al. nomogram resulted in 81% accuracy compared with 78% for the 2007 Partin tables. The Gallina et al. nomogram overestimated the true rate of SVI. Conversely, the Partin tables underestimated the true rate of SVI. Conclusion: The Gallina et al. nomogram offers greater accuracy (81%) than the 2007 Partin tables (78%). However, both tools are associated with calibration limitations that need to be acknowledged and considered before their implementation into clinical practice.« less
[Isolated sternal tuberculosis in immunocompétent adult].
Feki, W; Ketata, W; Mkaouar, N; Charfi, S; Moussa, N; Yangui, I; Kammoun, S
2018-04-01
Isolated sternal tuberculosis is a rarely described entity even in countries where tuberculosis is endemic. We report the case of 25 old years patient who presented with a chest wall mass. Imaging concluded to a (ring-enhancing hypodense soft tissue mass surrounding the sternum with sternal fracture). Malignancy was eliminated by a core needle biopsy. We noted clinical and radiological recovery with medical tuberculosis treatment. Neoplastic origin was removed by biopsy and anatomopathological study of the lesion. Copyright © 2018 Elsevier Masson SAS. All rights reserved.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Poulou, Loukia S., E-mail: ploukia@hotmail.com; Tsangaridou, Iris; Filippoussis, Petros
Bronchiolitis obliterans organizing pneumonia (BOOP) is a nonneoplastic, noninfectious lung disease with a diverse spectrum of imaging abnormalities and nonspecific symptoms diagnosed by open lung biopsy, transbroncial biopsy, and/or video-assisted thoracoscopy. The objective of this study was to retrospectively assess the role of percutaneous computed tomography (CT)-guided biopsy in early diagnosis of the disorder. Fourteen BOOP cases diagnosed by CT-guided biopsy were analyzed in terms of imaging abnormalities and complication rate. All had previously undergone a nondiagnostic procedure (bronchoscopy, transbronchial biopsy, bronchoalveolar lavage) to exclude infection or lung cancer. The most common imaging abnormalities in descending order were bilateral consolidationsmore » (5/14), unilateral tumor-like lesions (5/14), unilateral consolidations (3/14), and diffuse reticular pattern (1/14). Coexistent abnormalities (pleural effusions, nodules, ground-glass opacities) were observed in five patients. The complication rate was 4 of 14 (28.6%), including 2 cases of subclinical pneumothorax and 1 case of minor hemoptysis and local lung injury. None required intervention. We conclude that transthoracic CT-guided biopsy may be used in the diagnosis of BOOP in selected patients with mild complications. For the focal consolidation nodule/mass imaging pattern, CT-guided biopsy may prove to be a reasonable alternative to more invasive procedures.« less
Rose, Alan G; Park, Soon J
2005-01-01
Ventricular assist devices (VADs) are used as a bridge to cardiac transplantation or as a permanent or sometimes temporary treatment for end stage heart failure. Our autopsy and surgical pathology experience with VADs prior to August 2002 was reviewed. Noted were patient's age, sex, underlying (UCOD) and proximate causes of death (PCOD), duration of VAD implantation, presence of native or prosthetic valvar disease and organ complications. Myocardium from biopsies and explanted hearts were blindly assessed for coagulative necrosis (CN), contraction bands (CB), myocytolysis (MC), increased eosinophilia (IE), myocyte waviness (MW) and fibrosis (F). Each was graded as either mild (score 1), moderate (score 2) or severe (score 3). Autopsy patients: Twenty-one patients, with mean age 55 years (range 10-73), comprised 10 women and 11 men. UCOD was ischemic disease in 16 patients, dilated cardiomyopathy in 4 and aortic valve disease in 1. The mean duration of VAD implantation was 125.7 days (range 1-1095 days, S.D.=253.6). Five patients had biventricular VADs, and 16 had LVAD only. Acquired aortic valve fusion was noted in three patients. PCOD was VAD related in six, donor heart problem in four, cerebrovascular accident in four, miscellaneous in three, pulmonary hypertension in two and aortic disease in two patients. Morbidity: local liver necrosis in seven, acquired aortic valve disease in four, gut infarction in three, abdominal aortic aneurysm in two and host cell assault against VAD porcine aortic valves in one case. Biopsies and explanted hearts: Twenty-four patients had a mean age of 53 years (range 38-68, S.D.=8.6). VADs were implanted for 177.8 days (range 7-593 days, S.D.=151.1). Comparison of histologic scores of biopsies with explanted hearts showed the following: CN 1.33 (S.D.=1.4)/0.21 (S.D.=0.66; P<.001); CB: 2.1 (S.D.=0.93)/0.83 (S.D.=0.28; NS); MC: 0.88 (S.D.=1.19)/0.13 (S.D.=0.34; P<.01); IE: 1.71 (S.D.=1.27)/0.38 (S.D.=0.65; NS); fibrosis: 1.08 (S.D.=1.35)/1.75 (S.D.=1.26; NS); and MW: 1.50 (S.D.=1.22)/0.59 (S.D.=0.73; P<.01). Acquired aortic stenosis developed in six hearts, and one heart showed thrombotic occlusion of the left ventricular outflow tract below an aortic bioprosthesis. VAD significantly reduced the amount of CN, MC and MW in the left ventricle but may lead to acquired aortic stenosis of native aortic valves or total occlusive thrombosis of aortic prosthetic valves. Proximate cause of death was, most often, VAD related.
Pseudoangiomatous stromal hyperplasia causing massive breast enlargement
Bourke, Anita Geraldine; Tiang, Stephen; Harvey, Nathan; McClure, Robert
2015-01-01
Pseudoangiomatous stromal hyperplasia (PASH) of the breast is a benign mesenchymal proliferative process, initially described by Vuitch et al. We report an unusual case of a 46-year-old woman who presented with a 6-week history of bilateral massive, asymmetrical, painful enlargement of her breasts, without a history of trauma. On clinical examination, both breasts were markedly enlarged and oedematous, but there were no discrete palpable masses. Preoperative image-guided core biopsies and surgery showed PASH. PASH is increasingly recognised as an incidental finding on image-guided core biopsy performed for screen detected lesions. There are a few reported cases of PASH presenting as rapid breast enlargement. In our case, the patient presented with painful, asymmetrical, massive breast enlargement. Awareness needs to be raised of this entity as a differential diagnosis in massive, painful breast enlargement. PMID:26475873
Plaikner, Michaela; Gruber, Hannes; Henninger, Benjamin; Gruber, Leonhard; Kosiol, Juana; Loizides, Alexander
2016-03-01
We report on a rare case of an atypical located aneurysmal bone cyst (ABC) in the patella presenting with pathological fracture after trauma. Using all available diagnostic modalities and by means of ultrasound-guided core-needle biopsy an unclear and suspected pathological fractured cystic bone lesion in the patella of a young man could be further clarified. The acquired images suggested the diagnosis of a pathological fractured aneurysmal bone cyst after mild trauma. However, due to the extraordinary location and clinical presentation the diagnosis was secured by means of ultrasound-guided biopsy through a small cortical gap. As shown in this rare case of an atypical aneurysmal bone cyst of the patella, the quite seldom but sometimes possible ultrasound-guided biopsy of intraosseous lesions can help to achieve the diagnostic clarification and should also be taken into account as a non-standard procedure.
Sathyavathi, R.; Saha, Anushree; Soares, Jaqueline S.; Spegazzini, Nicolas; McGee, Sasha; Rao Dasari, Ramachandra; Fitzmaurice, Maryann; Barman, Ishan
2015-01-01
Microcalcifications are an early mammographic sign of breast cancer and frequent target for stereotactic biopsy. Despite their indisputable value, microcalcifications, particularly of the type II variety that are comprised of calcium hydroxyapatite deposits, remain one of the least understood disease markers. Here we employed Raman spectroscopy to elucidate the relationship between pathogenicity of breast lesions in fresh biopsy cores and composition of type II microcalcifications. Using a chemometric model of chemical-morphological constituents, acquired Raman spectra were translated to characterize chemical makeup of the lesions. We find that increase in carbonate intercalation in the hydroxyapatite lattice can be reliably employed to differentiate benign from malignant lesions, with algorithms based only on carbonate and cytoplasmic protein content exhibiting excellent negative predictive value (93–98%). Our findings highlight the importance of calcium carbonate, an underrated constituent of microcalcifications, as a spectroscopic marker in breast pathology evaluation and pave the way for improved biopsy guidance. PMID:25927331
NASA Astrophysics Data System (ADS)
Sathyavathi, R.; Saha, Anushree; Soares, Jaqueline S.; Spegazzini, Nicolas; McGee, Sasha; Rao Dasari, Ramachandra; Fitzmaurice, Maryann; Barman, Ishan
2015-04-01
Microcalcifications are an early mammographic sign of breast cancer and frequent target for stereotactic biopsy. Despite their indisputable value, microcalcifications, particularly of the type II variety that are comprised of calcium hydroxyapatite deposits, remain one of the least understood disease markers. Here we employed Raman spectroscopy to elucidate the relationship between pathogenicity of breast lesions in fresh biopsy cores and composition of type II microcalcifications. Using a chemometric model of chemical-morphological constituents, acquired Raman spectra were translated to characterize chemical makeup of the lesions. We find that increase in carbonate intercalation in the hydroxyapatite lattice can be reliably employed to differentiate benign from malignant lesions, with algorithms based only on carbonate and cytoplasmic protein content exhibiting excellent negative predictive value (93-98%). Our findings highlight the importance of calcium carbonate, an underrated constituent of microcalcifications, as a spectroscopic marker in breast pathology evaluation and pave the way for improved biopsy guidance.
Sathyavathi, R; Saha, Anushree; Soares, Jaqueline S; Spegazzini, Nicolas; McGee, Sasha; Rao Dasari, Ramachandra; Fitzmaurice, Maryann; Barman, Ishan
2015-04-30
Microcalcifications are an early mammographic sign of breast cancer and frequent target for stereotactic biopsy. Despite their indisputable value, microcalcifications, particularly of the type II variety that are comprised of calcium hydroxyapatite deposits, remain one of the least understood disease markers. Here we employed Raman spectroscopy to elucidate the relationship between pathogenicity of breast lesions in fresh biopsy cores and composition of type II microcalcifications. Using a chemometric model of chemical-morphological constituents, acquired Raman spectra were translated to characterize chemical makeup of the lesions. We find that increase in carbonate intercalation in the hydroxyapatite lattice can be reliably employed to differentiate benign from malignant lesions, with algorithms based only on carbonate and cytoplasmic protein content exhibiting excellent negative predictive value (93-98%). Our findings highlight the importance of calcium carbonate, an underrated constituent of microcalcifications, as a spectroscopic marker in breast pathology evaluation and pave the way for improved biopsy guidance.
Magnetic resonance imaging-ultrasound fusion biopsy for prediction of final prostate pathology.
Le, Jesse D; Stephenson, Samuel; Brugger, Michelle; Lu, David Y; Lieu, Patricia; Sonn, Geoffrey A; Natarajan, Shyam; Dorey, Frederick J; Huang, Jiaoti; Margolis, Daniel J A; Reiter, Robert E; Marks, Leonard S
2014-11-01
We explored the impact of magnetic resonance imaging-ultrasound fusion prostate biopsy on the prediction of final surgical pathology. A total of 54 consecutive men undergoing radical prostatectomy at UCLA after fusion biopsy were included in this prospective, institutional review board approved pilot study. Using magnetic resonance imaging-ultrasound fusion, tissue was obtained from a 12-point systematic grid (mapping biopsy) and from regions of interest detected by multiparametric magnetic resonance imaging (targeted biopsy). A single radiologist read all magnetic resonance imaging, and a single pathologist independently rereviewed all biopsy and whole mount pathology, blinded to prior interpretation and matched specimen. Gleason score concordance between biopsy and prostatectomy was the primary end point. Mean patient age was 62 years and median prostate specific antigen was 6.2 ng/ml. Final Gleason score at prostatectomy was 6 (13%), 7 (70%) and 8-9 (17%). A tertiary pattern was detected in 17 (31%) men. Of 45 high suspicion (image grade 4-5) magnetic resonance imaging targets 32 (71%) contained prostate cancer. The per core cancer detection rate was 20% by systematic mapping biopsy and 42% by targeted biopsy. The highest Gleason pattern at prostatectomy was detected by systematic mapping biopsy in 54%, targeted biopsy in 54% and a combination in 81% of cases. Overall 17% of cases were upgraded from fusion biopsy to final pathology and 1 (2%) was downgraded. The combination of targeted biopsy and systematic mapping biopsy was needed to obtain the best predictive accuracy. In this pilot study magnetic resonance imaging-ultrasound fusion biopsy allowed for the prediction of final prostate pathology with greater accuracy than that reported previously using conventional methods (81% vs 40% to 65%). If confirmed, these results will have important clinical implications. Copyright © 2014 American Urological Association Education and Research, Inc. Published by Elsevier Inc. All rights reserved.
Multi-Quadrant Biopsy Technique Improves Diagnostic Ability in Large Heterogeneous Renal Masses.
Abel, E Jason; Heckman, Jennifer E; Hinshaw, Louis; Best, Sara; Lubner, Meghan; Jarrard, David F; Downs, Tracy M; Nakada, Stephen Y; Lee, Fred T; Huang, Wei; Ziemlewicz, Timothy
2015-10-01
Percutaneous biopsy obtained from a single location is prone to sampling error in large heterogeneous renal masses, leading to nondiagnostic results or failure to detect poor prognostic features. We evaluated the accuracy of percutaneous biopsy for large renal masses using a modified multi-quadrant technique vs a standard biopsy technique. Clinical and pathological data for all patients with cT2 or greater renal masses who underwent percutaneous biopsy from 2009 to 2014 were reviewed. The multi-quadrant technique was defined as multiple core biopsies from at least 4 separate solid enhancing areas in the tumor. The incidence of nondiagnostic findings, sarcomatoid features and procedural complications was recorded, and concordance between biopsy specimens and nephrectomy pathology was compared. A total of 122 biopsies were performed for 117 tumors in 116 patients (46 using the standard biopsy technique and 76 using the multi-quadrant technique). Median tumor size was 10 cm (IQR 8-12). Biopsy was nondiagnostic in 5 of 46 (10.9%) standard and 0 of 76 (0%) multi-quadrant biopsies (p=0.007). Renal cell carcinoma was identified in 96 of 115 (82.0%) tumors and nonrenal cell carcinoma tumors were identified in 21 (18.0%). One complication occurred using the standard biopsy technique and no complications were reported using the multi-quadrant technique. Sarcomatoid features were present in 23 of 96 (23.9%) large renal cell carcinomas studied. Sensitivity for identifying sarcomatoid features was higher using the multi-quadrant technique compared to the standard biopsy technique at 13 of 15 (86.7%) vs 2 of 8 (25.0%) (p=0.0062). The multi-quadrant percutaneous biopsy technique increases the ability to identify aggressive pathological features in large renal tumors and decreases nondiagnostic biopsy rates. Copyright © 2015 American Urological Association Education and Research, Inc. Published by Elsevier Inc. All rights reserved.
Using the epigenetic field defect to detect prostate cancer in biopsy negative patients.
Truong, Matthew; Yang, Bing; Livermore, Andrew; Wagner, Jennifer; Weeratunga, Puspha; Huang, Wei; Dhir, Rajiv; Nelson, Joel; Lin, Daniel W; Jarrard, David F
2013-06-01
We determined whether a novel combination of field defect DNA methylation markers could predict the presence of prostate cancer using histologically normal transrectal ultrasound guided biopsy cores. Methylation was assessed using quantitative Pyrosequencing® in a training set consisting of 65 nontumor and tumor associated prostate tissues from University of Wisconsin. A multiplex model was generated using multivariate logistic regression and externally validated in blinded fashion in a set of 47 nontumor and tumor associated biopsy specimens from University of Washington. We observed robust methylation differences in all genes at all CpGs assayed (p <0.0001). Regression models incorporating individual genes (EVX1, CAV1 and FGF1) and a gene combination (EVX1 and FGF1) discriminated nontumor from tumor associated tissues in the original training set (AUC 0.796-0.898, p <0.001). On external validation uniplex models incorporating EVX1, CAV1 or FGF1 discriminated tumor from nontumor associated biopsy negative specimens (AUC 0.702, 0.696 and 0.658, respectively, p <0.05). A multiplex model (EVX1 and FGF1) identified patients with prostate cancer (AUC 0.774, p = 0.001) and had a negative predictive value of 0.909. Comparison between 2 separate cores in patients in this validation set revealed similar methylation defects, indicating detection of a widespread field defect. A widespread epigenetic field defect can be used to detect prostate cancer in patients with histologically negative biopsies. To our knowledge this assay is unique, in that it detects alterations in nontumor cells. With further validation this marker combination (EVX1 and FGF1) has the potential to decrease the need for repeat prostate biopsies, a procedure associated with cost and complications. Copyright © 2013 American Urological Association Education and Research, Inc. Published by Elsevier Inc. All rights reserved.
Berry, John S; Trappey, Alfred F; Vreeland, Timothy J; Pattyn, Adam R; Clifton, Guy T; Berry, Elizabeth A; Schneble, Erika J; Kirkpatrick, Aaron D; Saenger, Jeffrey S; Peoples, George E
2016-01-01
Background: The optimal treatment of flat epithelial atypia (FEA) found on breast core needle biopsy (CNB) is controversial. We performed a retrospective review of our institutional experience with FEA to determine if excisional biopsy may be deferred. Methods: Surgical records from 2009 to 2012 were reviewed for FEA diagnosis. After exclusion for concomitant lesions, CNBs of pure FEA were classified using a previously agreed upon descriptor of “focal” versus “prominent”. Data was analyzed with the Fisher's Exact and Student-t test as appropriate. Results: Of 71 CNBs evaluated, pure FEA was identified on 27 CNBs. Final excisional biopsy was benign in 24 of 27 cases (88%) with associated ductal carcinoma in-situ (DCIS) in 3 of 27 cases (11%). Eighteen of 27 (67%) CNBs were classified as focal while 9 (33%) were described as prominent. Zero of the 18 focal patients had a malignancy compared to 3 of the 9 in the prominent group (0% vs 33%, p=0.02). Of the 27 pure FEA CNBs, 6 patients had a personal history of breast carcinoma, five DCIS and one invasive ductal carcinoma. No malignancies were found in the 21 patients without a personal history of breast carcinoma versus three in the patients with a positive history (0/21 v 3/6, p=0.007). Conclusions: Our data suggests those women who have adequate sampling and sectioning of CNBs, with focal, pure FEA on pathology, and are without a personal history of breast cancer may undergo a period of imaging surveillance. Conversely, patients with a history of breast cancer or pure, prominent FEA on CNB disease should proceed to excisional biopsy. PMID:26722353
Logan-Young, W; Dawson, A E; Wilbur, D C; Avila, E E; Tomkiewicz, Z M; Sheils, L A; Laczin, J A; Taylor, A S
1998-05-15
Judicious utilization of fine-needle aspiration cytology (FNAC) and 14-gauge core needle biopsy (CB) theoretically should result in greater accuracy in breast carcinoma diagnosis and fewer unnecessary open surgical biopsies (OSBs), thus lowering health care costs. In 1995 in Rochester, New York, the ratio of open surgical breast biopsies per each verified breast carcinoma (OSB/Ca) in a freestanding breast clinic (EWBC) was compared with the OSB/Ca ratio of all physicians in the remainder of the city. The EWBC differs from all other diagnostic facilities in Rochester in that it routinely performs FNAC and CB. The EWBC recommended 462 OSBs resulting in 310 verified carcinomas, for a OSB/Ca ratio of 1.5. The physicians in the remainder of the city recommended 2036 OSBs resulting in 513 verified carcinomas, for a OSB/Ca ratio of 4.0. If the EWBC OSB/Ca ratio had been identical to the remainder of the city, the number of extra OSBs recommended by the clinic would have been 778, resulting in an additional cost of $1,712,082. When the added cost of the 2594 FNACs ($256,285) and 403 CBs ($252,278) performed by the clinic was subtracted from the $1,712,082, the freestanding breast clinic cost savings was $1,203,519. The lymph node metastasis rate of 19% for the breast carcinomas diagnosed in clinic patients was identical to that of the women with breast carcinoma in the remainder of the city. Utilization of FNAC and CB allows radiologists to lower their OSB/Ca ratio without sacrificing early detection. In this study, these less expensive procedures result in lowered medical costs for the health care system.
Gruber, R; Walter, E; Helbich, T H
2010-06-01
To examine the budget impact of ultrasound-guided 14-g large core breast biopsy (US-guided LCBB) by comparing the costs of US-guided LCBB and open surgical biopsy (OSB); to calculate the cost savings attributable to US-guided LCBB; and to assess the frequency with which US-guided LCBB obviates the need for an OSB. In a retrospective study, we reviewed 399 suspicious breast lesions on which US-guided LCBB and OSB or, in cases of benign histology, clinical follow-up, were performed. Cost savings were calculated using nationally allowed flat rates (A-drg) and patient charges. Costs were measured from both, a hospital and a socioeconomic perspective. Deterministic sensitivity analyses were simulated to assess the extent of achievable cost savings. Overall cost savings for US-guided LCBB over OSB were euro 977 (euro 2,337/euro 3,314) per case from a hospital perspective, resulting in a total cost decrease of 30% for the diagnosis of suspicious breast lesions. From a socioeconomic perspective, cost savings were euro 1,542 (euro 2,600/euro 4,142) per case, resulting in a 37% reduction in biopsy cost. US-guided LCBB obviated the need for a surgical procedure in 240 (60%) of 399 women. In all four sensitivity analyses, costs of US-guided LCBB remained lower than that of OSB. From an economic perspective, US-guided LCBB is highly recommended for the diagnosis of suspicious breast lesions, as this procedure reduces the cost of diagnosis substantially. In Austria, annual cost savings would be euro 18.5 million. Copyright (c) 2009 Elsevier Ireland Ltd. All rights reserved.
Berry, John S; Trappey, Alfred F; Vreeland, Timothy J; Pattyn, Adam R; Clifton, Guy T; Berry, Elizabeth A; Schneble, Erika J; Kirkpatrick, Aaron D; Saenger, Jeffrey S; Peoples, George E
2016-01-01
The optimal treatment of flat epithelial atypia (FEA) found on breast core needle biopsy (CNB) is controversial. We performed a retrospective review of our institutional experience with FEA to determine if excisional biopsy may be deferred. Surgical records from 2009 to 2012 were reviewed for FEA diagnosis. After exclusion for concomitant lesions, CNBs of pure FEA were classified using a previously agreed upon descriptor of "focal" versus "prominent". Data was analyzed with the Fisher's Exact and Student-t test as appropriate. Of 71 CNBs evaluated, pure FEA was identified on 27 CNBs. Final excisional biopsy was benign in 24 of 27 cases (88%) with associated ductal carcinoma in-situ (DCIS) in 3 of 27 cases (11%). Eighteen of 27 (67%) CNBs were classified as focal while 9 (33%) were described as prominent. Zero of the 18 focal patients had a malignancy compared to 3 of the 9 in the prominent group (0% vs 33%, p=0.02). Of the 27 pure FEA CNBs, 6 patients had a personal history of breast carcinoma, five DCIS and one invasive ductal carcinoma. No malignancies were found in the 21 patients without a personal history of breast carcinoma versus three in the patients with a positive history (0/21 v 3/6, p=0.007). Our data suggests those women who have adequate sampling and sectioning of CNBs, with focal, pure FEA on pathology, and are without a personal history of breast cancer may undergo a period of imaging surveillance. Conversely, patients with a history of breast cancer or pure, prominent FEA on CNB disease should proceed to excisional biopsy.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Garnon, J., E-mail: juliengarnon@gmail.com; Ramamurthy, N., E-mail: nitin-ramamurthy@hotmail.com; Caudrelier J, J., E-mail: caudjean@yahoo.fr
2016-05-15
ObjectiveTo evaluate the diagnostic accuracy and safety of magnetic resonance imaging (MRI)-guided percutaneous biopsy of mediastinal masses performed using a wide-bore high-field scanner.Materials and MethodsThis is a retrospective study of 16 consecutive patients (8 male, 8 female; mean age 74 years) who underwent MRI-guided core needle biopsy of a mediastinal mass between February 2010 and January 2014. Size and location of lesion, approach taken, time for needle placement, overall duration of procedure, and post-procedural complications were evaluated. Technical success rates and correlation with surgical pathology (where available) were assessed.ResultsTarget lesions were located in the anterior (n = 13), middle (n = 2), and posterior mediastinummore » (n = 1), respectively. Mean size was 7.2 cm (range 3.6–11 cm). Average time for needle placement was 9.4 min (range 3–18 min); average duration of entire procedure was 42 min (range 27–62 min). 2–5 core samples were obtained from each lesion (mean 2.6). Technical success rate was 100 %, with specimens successfully obtained in all 16 patients. There were no immediate complications. Histopathology revealed malignancy in 12 cases (4 of which were surgically confirmed), benign lesions in 3 cases (1 of which was false negative following surgical resection), and one inconclusive specimen (treated as inaccurate since repeat CT-guided biopsy demonstrated thymic hyperplasia). Sensitivity, specificity, positive predictive value, negative predictive value, and accuracy in our study were 92.3, 100, 100, 66.7, and 87.5 %, respectively.ConclusionMRI-guided mediastinal biopsy is a safe procedure with high diagnostic accuracy, which may offer a non-ionizing alternative to CT guidance.« less
Słapa, Rafał Z.; Jakubowski, Wiesław S.; Migda, Bartosz; Dmowski, Tadeusz
2014-01-01
Aim Sonoelastography is a technique that assesses tissue hardness/compressibility. Utility and sensitivity of the method in prostate cancer diagnostics were assessed compared to the current gold standard in prostate cancer diagnostics i.e. systematic biopsy. Material and methods The study involved 84 patients suspected of prostate cancer based on elevated PSA levels or abnormal per rectal examination findings. Sonoelastography was used to evaluate the prostate gland. In the case of regions with hardness two-fold greater than that of symmetric prostate area (strain ratio >2), targeted biopsy was used; which was followed by an ultrasound-guided 8- or 10-core systematic biopsy (regardless of sonoelastography-indicated sites) as a reference point. Results The mean age of patients was 69 years. PSA serum levels ranged between 1.02 and 885 ng/dl. The mean prostate volume was 62 ml (19–149 ml). Prostate cancer was found in 39 out of 84 individuals. Statistically significant differences in strain ratios between cancers and benign lesions were shown. Sonoelastography guided biopsy revealed 30 lesions – overall sensitivity 77% (sensitivity of the method – 81%). Sonoelastographic sensitivity increased depending on cancer stage according to the Gleason grading system: 6–60%, 7–75%, 8–83%, 9/10–100%. The estimated sensitivity of systematic biopsy was 92%. Conclusions Sonoelastography shows higher diagnostic sensitivity in prostate cancer diagnostics compared to conventional imaging techniques, i.e. grey-scale TRUS, Doppler ultrasound. It allows to reduce the number of collected tissue cores, and thus limit the incidence of complications as well as the costs involved. Sonoelastography using the determination of compressibility ratio for symmetrical prostatic regions may prove useful in the detection of clinically significant prostate cancer. PMID:26674065
DOE Office of Scientific and Technical Information (OSTI.GOV)
Fritz, Jan, E-mail: jfritz9@jhmi.edu; Tzaribachev, Nikolay; Thomas, Christoph
2012-02-15
Purpose: To report the safety and diagnostic performance of magnetic resonance (MRI)-guided core biopsy of osseous lesions in children with chronic recurrent multifocal osteomyelitis (CRMO) that were visible on MRI but were occult on radiography and computed tomography (CT). Materials and Methods: A retrospective analysis of MRI-guided osseous biopsy performed in seven children (four girls and three boys; mean age 13 years (range 11 to 14) with CRMO was performed. Indication for using MRI guidance was visibility of lesions by MRI only. MRI-guided procedures were performed with 0.2-Tesla (Magnetom Concerto; Siemens, Erlangen, Germany; n = 5) or 1.5-T (Magnetom Espree;more » Siemens; n = 2) open MRI systems. Core needle biopsy was obtained using an MRI-compatible 4-mm drill system. Conscious sedation or general anesthesia was used. Parameters evaluated were lesion visibility, technical success, procedure time, complications and microbiology, cytology, and histopathology findings. Results: Seven of seven (100%) targeted lesions were successfully visualized and sampled. All obtained specimens were sufficient for histopathological analysis. Length of time of the procedures was 77 min (range 64 to 107). No complications occurred. Histopathology showed no evidence of malignancy, which was confirmed at mean follow-up of 50 months (range 28 to 78). Chronic nonspecific inflammation characteristic for CRMO was present in four of seven (58%) patients, and edema with no inflammatory cells was found in three of seven (42%) patients. There was no evidence of infection in any patient. Conclusion: MRI-guided osseous biopsy is a safe and accurate technique for the diagnosis of pediatric CRMO lesions that are visible on MRI only.« less
Tai, Dean C.S.; Wang, Shi; Cheng, Chee Leong; Peng, Qiwen; Yan, Jie; Chen, Yongpeng; Sun, Jian; Liang, Xieer; Zhu, Youfu; Rajapakse, Jagath C.; Welsch, Roy E.; So, Peter T.C.; Wee, Aileen; Hou, Jinlin; Yu, Hanry
2014-01-01
Background & Aims There is increasing need for accurate assessment of liver fibrosis/cirrhosis. We aimed to develop qFibrosis, a fully-automated assessment method combining quantification of histopathological architectural features, to address unmet needs in core biopsy evaluation of fibrosis in chronic hepatitis B (CHB) patients. Methods qFibrosis was established as a combined index based on 87 parameters of architectural features. Images acquired from 25 Thioacetamide-treated rat samples and 162 CHB core biopsies were used to train and test qFibrosis and to demonstrate its reproducibility. qFibrosis scoring was analyzed employing Metavir and Ishak fibrosis staging as standard references, and collagen proportionate area (CPA) measurement for comparison. Results qFibrosis faithfully and reliably recapitulates Metavir fibrosis scores, as it can identify differences between all stages in both animal samples (p <0.001) and human biopsies (p <0.05). It is robust to sampling size, allowing for discrimination of different stages in samples of different sizes (area under the curve (AUC): 0.93–0.99 for animal samples: 1–16 mm2; AUC: 0.84–0.97 for biopsies: 10–44 mm in length). qFibrosis can significantly predict staging underestimation in suboptimal biopsies (<15 mm) and under- and over-scoring by different pathologists (p <0.001). qFibrosis can also differentiate between Ishak stages 5 and 6 (AUC: 0.73, p = 0.008), suggesting the possibility of monitoring intra-stage cirrhosis changes. Best of all, qFibrosis demonstrates superior performance to CPA on all counts. Conclusions qFibrosis can improve fibrosis scoring accuracy and throughput, thus allowing for reproducible and reliable analysis of efficacies of anti-fibrotic therapies in clinical research and practice. PMID:24583249
Mao, Feng; Dong, Yi; Ji, Zhengbiao; Cao, Jiaying; Wang, Wen-Ping
2017-01-01
Aim. To investigate the value of contrast-enhanced ultrasound (CEUS) guided biopsy of undetermined abdominal lesions in multidisciplinary treatment (MDT) decision-making approach. Methods. Between Jan 2012 and Dec 2015, 60 consecutive patients (male, 37; female, 23; mean age, 51.3 years ± 14.6) who presented with undetermined abdominal lesions were included. CEUS and core needle percutaneous biopsy was performed under real-time CEUS guidance in all lesions. Data were recorded and compared with conventional ultrasound (US) guidance group ( n = 75). All CEUS findings and clinical data were evaluated in MDT. Results. CEUS enabled the delimitation of more (88.3% versus 41.3%) and larger (14.1 ± 10.7 mm versus 32.3 ± 18.5 mm) nonenhanced necrotic areas. More inner (20.0% versus 6.7%) and surrounding (18.3% versus 2.7%) major vessels were visualized and avoided during biopsies. CEUS-guided biopsy increased the diagnostic accuracy from 93.3% to 98.3%, with correct diagnosis in 57 of 60 lesions (95.0%). The therapeutic plan was influenced by CEUS guided biopsies findings in the majority of patients (98.3%). Conclusion. The combination of CEUS guided biopsy and MDT decision-making approach is useful in the diagnostic work-up and therapeutic management.
Shipitsin, M; Small, C; Choudhury, S; Giladi, E; Friedlander, S; Nardone, J; Hussain, S; Hurley, A D; Ernst, C; Huang, Y E; Chang, H; Nifong, T P; Rimm, D L; Dunyak, J; Loda, M; Berman, D M; Blume-Jensen, P
2014-09-09
Key challenges of biopsy-based determination of prostate cancer aggressiveness include tumour heterogeneity, biopsy-sampling error, and variations in biopsy interpretation. The resulting uncertainty in risk assessment leads to significant overtreatment, with associated costs and morbidity. We developed a performance-based strategy to identify protein biomarkers predictive of prostate cancer aggressiveness and lethality regardless of biopsy-sampling variation. Prostatectomy samples from a large patient cohort with long follow-up were blindly assessed by expert pathologists who identified the tissue regions with the highest and lowest Gleason grade from each patient. To simulate biopsy-sampling error, a core from a high- and a low-Gleason area from each patient sample was used to generate a 'high' and a 'low' tumour microarray, respectively. Using a quantitative proteomics approach, we identified from 160 candidates 12 biomarkers that predicted prostate cancer aggressiveness (surgical Gleason and TNM stage) and lethal outcome robustly in both high- and low-Gleason areas. Conversely, a previously reported lethal outcome-predictive marker signature for prostatectomy tissue was unable to perform under circumstances of maximal sampling error. Our results have important implications for cancer biomarker discovery in general and development of a sampling error-resistant clinical biopsy test for prediction of prostate cancer aggressiveness.
Umbilical Negative Pressure Dressing for Transumbilical Appendectomy in Childern.
Seifarth, Federico G; Kundu, Neilendu; Guerron, Alfredo D; Garland, Mary M; Gaffley, Michaela W G; Worley, Sarah; Knight, Colin G
2016-01-01
Transumbilical laparoscopic-assisted appendectomy (TULAA) carries a high risk for surgical site infection. We investigated the effect of a bio-occlusive umbilical vacuum dressing on wound infection rates after TULAA for patients with acute appendicitis and compared to it with a conventional 3-port appendectomy with a nonvacuum dressing. This study was a retrospective chart review of 1377 patients (2-20 years) undergoing laparoscopic appendectomy for acute appendicitis in 2 tertiary care referral centers from January 2007 through December 2012. Twenty-two different operative technique/dressing variations were documented. The 6 technique/dressing groups with >50 patients were assessed, including a total of 1283 patients. The surgical site infection rate of the 220 patients treated with TULAA and application of an umbilical vacuum dressing with dry gauze is 1.8% (95% CI, 0.0-10.3%). This compares to an infection rate of 4.1% (95% CI, 1.3-10.5%) in 97 patients with dry dressing without vacuum. In the 395 patients who received an umbilical vacuum dressing with gauze and bacitracin, the surgical site infection rate was found to be 4.3% (95% CI, 2.7-6.8%). Application of an umbilical negative-pressure dressing with dry gauze lowers the rate of umbilical site infections in patients undergoing transumbilical laparoscopic-assisted appendectomy for acute appendicitis.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Ward, C.R.
2003-04-08
On December 2, 2002, Remote and Specialty Equipment Systems (RSES) of the Savannah River Technology Center (SRTC) was requested to build a remotely operated crawler to assist in cleaning the Defense Waste Processing Facility (DWPF) melt cell floor of glass, tools, and other debris. The crawler was to assist a grapple and vacuum system in cleaning the cell. The crawler was designed to push glass and debris into piles so that the grapple could pick up the material and place it in waste bins. The crawler was also designed to maneuver the end of the vacuum hose, if needed. Inmore » addition, the crawler was designed to clean the area beneath the cell worktable that was inaccessible to the grapple and vacuum system. Originally, the system was to be ready for deployment by December 17. The date was moved up to December 12 to better utilize the available time for clean up. The crawler was designed and built in 10 days and completed cleaning the melt cell in 8 days. Due to initial problems with the grapple and vacuum system, the crawler completed essentially all of the cleanup tasks by itself. The crawler also cleaned an area on the west side of the cell that was not initially slated for cleaning.« less
Shear-Wave Elastography for the Differential Diagnosis of Breast Papillary Lesions
Chung, Jin; Lee, Won Kyung; Cha, Eun-Suk; Lee, Jee Eun; Kim, Jeoung Hyun; Ryu, Young Hoon
2016-01-01
Objective To evaluate the diagnostic performance of shear-wave elastography (SWE) for the differential diagnosis of breast papillary lesions. Methods This study was an institutional review board-approved retrospective study, with a waiver of informed consent. A total of 79 breast papillary lesions in 71 consecutive women underwent ultrasound and SWE prior to biopsy. Ultrasound features and quantitative SWE parameters were recorded for each lesion. All lesions were surgically excised or excised using an ultrasound-guided vacuum-assisted method. The diagnostic performances of the quantitative SWE parameters were compared using the area under the receiver operating characteristic curve (AUC). Results Of the 79 lesions, six (7.6%) were malignant and 12 (15.2%) were atypical. Orientation, margin, and the final BI-RADS ultrasound assessments were significantly different for the papillary lesions (p < 0.05). All qualitative SWE parameters were significantly different (p < 0.05). The AUC values for SWE parameters of benign and atypical or malignant papillary lesions ranged from 0.707 to 0.757 (sensitivity, 44.4–94.4%; specificity, 42.6–88.5%). The maximum elasticity and the mean elasticity showed the highest AUC (0.757) to differentiate papillary lesions. Conclusion SWE provides additional information for the differential diagnosis of breast papillary lesions. Quantitative SWE features were helpful to differentiate breast papillary lesions. PMID:27893857
McAfee, John L; Warren, Christine B; Prayson, Richard A
2017-08-01
Ultrastructural evaluation of skin biopsies has been utilized for diagnosis of mitochondrial disease. This study investigates how frequently skin biopsies reveal mitochondrial abnormalities, correlates skin and muscle biopsy findings, and describes clinical diagnoses rendered following the evaluation. A retrospective review of surgical pathology reports from 1990 to 2015 identified skin biopsies examined by electron microscopy for suspected metabolic disease. A total of 630 biopsies were included from 615 patients. Of these patients, 178 also underwent a muscle biopsy. Of the 630 skin biopsies, 75 (12%) showed ultrastructural abnormalities and 34 (5%) specifically showed mitochondrial abnormalities including increased size (n=27), reduced or abnormal cristae (n=23), dense matrices (n=20), and increased number (n=8). Additional findings included lysosomal abnormalities (n=13), lipid accumulation (n=2) or glycogen accumulation (n=1). Of the 34 patients with mitochondrial abnormalities on skin biopsy, 20 also had muscle biopsies performed and nine showed abnormalities suggestive of a mitochondrial disorder including absent cytochrome oxidase staining (n=2), increased subsarcolemmal NADH, SDH, or cytochrome oxidase staining (n=1), or ultrastructural findings including large mitochondrial size (n=5), abnormal mitochondrial structure (n=5), and increased mitochondrial number (n=4). The most common presenting symptoms were intellectual disability (n=13), seizures (n=12), encephalopathy (n=9), and gastrointestinal disturbances (n=9). At last known follow-up, 12 patients had a definitive diagnosis of a mitochondrial disorder. One patient each had Complex I deficiency, Complex III deficiency, Charcot-Marie-Tooth disease, pyruvate dehydrogenase deficiency, and Phelan-McDermid syndrome. Our results suggest that skin biopsy sometimes yields diagnostic clues suggestive of a mitochondrial cytopathy in cases with a negative muscle biopsy. Copyright © 2017 Elsevier Inc. All rights reserved.
A fully actuated robotic assistant for MRI-guided prostate biopsy and brachytherapy
NASA Astrophysics Data System (ADS)
Li, Gang; Su, Hao; Shang, Weijian; Tokuda, Junichi; Hata, Nobuhiko; Tempany, Clare M.; Fischer, Gregory S.
2013-03-01
Intra-operative medical imaging enables incorporation of human experience and intelligence in a controlled, closed-loop fashion. Magnetic resonance imaging (MRI) is an ideal modality for surgical guidance of diagnostic and therapeutic procedures, with its ability to perform high resolution, real-time, high soft tissue contrast imaging without ionizing radiation. However, for most current image-guided approaches only static pre-operative images are accessible for guidance, which are unable to provide updated information during a surgical procedure. The high magnetic field, electrical interference, and limited access of closed-bore MRI render great challenges to developing robotic systems that can perform inside a diagnostic high-field MRI while obtaining interactively updated MR images. To overcome these limitations, we are developing a piezoelectrically actuated robotic assistant for actuated percutaneous prostate interventions under real-time MRI guidance. Utilizing a modular design, the system enables coherent and straight forward workflow for various percutaneous interventions, including prostate biopsy sampling and brachytherapy seed placement, using various needle driver configurations. The unified workflow compromises: 1) system hardware and software initialization, 2) fiducial frame registration, 3) target selection and motion planning, 4) moving to the target and performing the intervention (e.g. taking a biopsy sample) under live imaging, and 5) visualization and verification. Phantom experiments of prostate biopsy and brachytherapy were executed under MRI-guidance to evaluate the feasibility of the workflow. The robot successfully performed fully actuated biopsy sampling and delivery of simulated brachytherapy seeds under live MR imaging, as well as precise delivery of a prostate brachytherapy seed distribution with an RMS accuracy of 0.98mm.
Multiple cores of Gleason score 6 correlate with favourable findings at radical prostatectomy
Ellis, Carla L.; Walsh, Patrick C.; Partin, Alan W.; Epstein, Jonathan I.
2014-01-01
Objective To establish whether the good prognosis of Gleason score 6 (GS6) is maintained in the setting of multiple involved cores. Patients and Methods In total, 6156 men (from 1 April 2000 to 30 April 2007) with GS6 on biopsy underwent radical prostatectomy (RP) at our institution. The number of positive cores was correlated with the outcome at RP. Results More positive cores correlated with less organ-confined disease (P < 0.001), positive margins (P < 0.012), increasing RP grade (P < 0.001) and increased seminal vesicles/lymph node involvement (P = 0.012). For men with data available, the actuarial risk of being biochemically free of disease at 5 years was 93.2% when ≤6 cores were positive (812 men followed to 5 years) vs 89.1% if >6 cores were positive (41 men followed to 2 years) (P = 0.6). Although the predicted ‘cure rate’ of >75% probability of a tumour showing no evidence of biochemical recurrence at 10 years after RP was statistically different between cases with ≤6 vs >6 positive cores (P < 0.0001), the outcome in both groups was still favourable (90.5% vs 84%). Partin-like tables were generated factoring in the number of positive cores to predict organ-confined disease as a guide for urologists to perform nerve-sparing surgery. For example, with T1c disease, there was a ≥75% probability of organ-confined disease with one to three positive cores regardless of prostate-specific antigen (PSA) level, and the same probability was present with four to six positive cores and a PSA level of 0–4 ng/mL. Conclusion A low Gleason score on biopsy is a powerful prognostic finding, such that this favourable outcome is maintained even in the setting of multiple positive cores with GS6. PMID:23350787
Multiple cores of Gleason score 6 correlate with favourable findings at radical prostatectomy.
Ellis, Carla L; Walsh, Patrick C; Partin, Alan W; Epstein, Jonathan I
2013-06-01
To establish whether the good prognosis of Gleason score 6 (GS6) is maintained in the setting of multiple involved cores. In total, 6156 men (from 1 April 2000 to 30 April 2007) with GS6 on biopsy underwent radical prostatectomy (RP) at our institution. The number of positive cores was correlated with the outcome at RP. More positive cores correlated with less organ-confined disease (P < 0.001), positive margins (P < 0.012), increasing RP grade (P < 0.001) and increased seminal vesicles/lymph node involvement (P = 0.012). For men with data available, the actuarial risk of being biochemically free of disease at 5 years was 93.2% when ≤6 cores were positive (812 men followed to 5 years) vs 89.1% if >6 cores were positive (41 men followed to 2 years) (P = 0.6). Although the predicted 'cure rate' of >75% probability of a tumour showing no evidence of biochemical recurrence at 10 years after RP was statistically different between cases with ≤6 vs >6 positive cores (P < 0.0001), the outcome in both groups was still favourable (90.5% vs 84%). Partin-like tables were generated factoring in the number of positive cores to predict organ-confined disease as a guide for urologists to perform nerve-sparing surgery. For example, with T1c disease, there was a ≥75% probability of organ-confined disease with one to three positive cores regardless of prostate-specific antigen (PSA) level, and the same probability was present with four to six positive cores and a PSA level of 0-4 ng/mL. A low Gleason score on biopsy is a powerful prognostic finding, such that this favourable outcome is maintained even in the setting of multiple positive cores with GS6. © 2013 BJU International.
NASA Astrophysics Data System (ADS)
Bergado, D. T.; Long, P. V.; Chaiyaput, S.; Balasubramaniam, A. S.
2018-04-01
Soft ground improvement techniques have become most practical and popular methods to increase soil strength, soil stiffness and reduce soil compressibility including the soft Bangkok clay. This paper focuses on comparative performances of prefabricated vertical drain (PVD) using surcharge, vacuum and heat preloading as well as the cement-admixed clay of Deep Cement Mixing (DCM) and Stiffened DCM (SDCM) methods. The Vacuum-PVD can increase the horizontal coefficient of consolidation, Ch, resulting in faster rate of settlement at the same magnitudes of settlement compared to Conventional PVD. Several field methods of applying vacuum preloading are also compared. Moreover, the Thermal PVD and Thermal Vacuum PVD can increase further the coefficient of horizontal consolidation, Ch, with the associated reduction of kh/ks values by reducing the drainage retardation effects in the smear zone around the PVD which resulted in faster rates of consolidation and higher magnitudes of settlements. Furthermore, the equivalent smear effect due to non-uniform consolidation is also discussed in addition to the smear due to the mechanical installation of PVDs. In addition, a new kind of reinforced deep mixing method, namely Stiffened Deep Cement Mixing (SDCM) pile is introduced to improve the flexural resistance, improve the field quality control, and prevent unexpected failures of the Deep Cement Mixing (DCM) pile. The SDCM pile consists of DCM pile reinforced with the insertion of precast reinforced concrete (RC) core. The full scale test embankment on soft clay improved by SDCM and DCM piles was also analysed. Numerical simulations using the 3D PLAXIS Foundation finite element software have been done to understand the behavior of SDCM and DCM piles. The simulation results indicated that the surface settlements decreased with increasing lengths of the RC cores, and, at lesser extent, increasing sectional areas of the RC cores in the SDCM piles. In addition, the lateral movements decreased by increasing the lengths (longer than 4 m) and, the sectional areas of the RC cores in the SDCM piles. The results of the numerical simulations closely agreed with the observed data and successfully verified the parameters affecting the performances and behavior of both SDCM and DCM piles.
Intraoperative loss of core biopsy clips: clinical implications.
Calhoun, Kristine; Giuliano, Armando; Brenner, R James
2008-03-01
The purpose of this study was to report the occurrence of intraoperative loss of metallic marking clips placed during image-guided biopsy and to hypothesize the likely mechanism of this clinical problem. From January 2003 through December 2004, patients presenting for preoperative mammographic localization and operative excision of biopsy site marking clips were identified. Age, method of image-guided biopsy, number of excised specimens, and tissue diagnosis were determined. Specimen radiographs were used to identify cases of suspected intraoperative clip loss. Clips absent on specimen radiographs and postoperative mammograms were defined as lost intraoperatively. Biopsy site marking clips, surgical clips, and suction device apertures were measured. In 78 surgical procedures performed during the study period, three (3.8%) of the patients experienced clip loss. Specimen radiographs confirmed the absence of clips in all submitted tissues. A median of four (range, three to five) separate biopsy specimens were excised among these three cases. A healing biopsy site from the stereotactic biopsy preceding the clip placement procedure was confirmed in all cases. Absence of the metallic clip was confirmed on postoperative mammograms. The apertures of two types of suction device were four and two times those of the biopsy clips. Intraoperative loss of metallic clips placed at the conclusion of image-guided breast biopsy is unusual but can occur during subsequent surgical excision. Repeated inability to locate the clip on specimen radiographs after accurate preoperative localization should raise the suspicion that the target clip has been lost, not missed, during surgery, likely because of inadvertent removal of the clip with the suction device.
Dell'Angela, M.; Anniyev, T.; Beye, M.; ...
2015-03-01
Vacuum space charge-induced kinetic energy shifts of O 1s and Ru 3d core levels in femtosecond soft X-ray photoemission spectra (PES) have been studied at a free electron laser (FEL) for an oxygen layer on Ru(0001). We fully reproduced the measurements by simulating the in-vacuum expansion of the photoelectrons and demonstrate the space charge contribution of the high-order harmonics in the FEL beam. Employing the same analysis for 400 nm pump-X-ray probe PES, we can disentangle the delay dependent Ru 3d energy shifts into effects induced by space charge and by lattice heating from the femtosecond pump pulse.
Dell'Angela, M; Anniyev, T; Beye, M; Coffee, R; Föhlisch, A; Gladh, J; Kaya, S; Katayama, T; Krupin, O; Nilsson, A; Nordlund, D; Schlotter, W F; Sellberg, J A; Sorgenfrei, F; Turner, J J; Öström, H; Ogasawara, H; Wolf, M; Wurth, W
2015-03-01
Vacuum space charge induced kinetic energy shifts of O 1s and Ru 3d core levels in femtosecond soft X-ray photoemission spectra (PES) have been studied at a free electron laser (FEL) for an oxygen layer on Ru(0001). We fully reproduced the measurements by simulating the in-vacuum expansion of the photoelectrons and demonstrate the space charge contribution of the high-order harmonics in the FEL beam. Employing the same analysis for 400 nm pump-X-ray probe PES, we can disentangle the delay dependent Ru 3d energy shifts into effects induced by space charge and by lattice heating from the femtosecond pump pulse.
Erdahl, Lillian M.; Boughey, Judy C.
2014-01-01
Use of sentinel lymph node biopsy for axillary staging of patients with breast cancer treated with neoadjuvant chemotherapy has been widely debated. Questions arise regarding the accuracy of sentinel lymph node biopsy in axillary staging for these patients and its use to determine further local–regional therapy, including surgery and radiation therapy. For patients who are clinically node-negative at presentation, sentinel lymph node biopsy enables accurate staging of the axilla after neoadjuvant chemotherapy, and determination of which patients should go on to further axillary surgery and regional nodal radiation therapy. Importantly, performing axillary staging after completion of chemotherapy, rather than before chemotherapy, enables assessment of response to chemotherapy and the extent of residual disease. This information can assist the planning of adjuvant treatment. Recent data indicate that sentinel node biopsy can also be used to assess disease response after neoadjuvant chemotherapy for patients with clinical N1 disease at presentation. PMID:24683440
Cole, Eric; Margel, David; Greenspan, Michael; Shayegan, Bobby; Matsumoto, Edward; Fischer, Marc A; Patlas, Michael; Daya, Dean; Pinthus, Jehonathan H
2014-05-03
The prostatic anterior zone (AZ) is not targeted routinely by TRUS guided prostate biopsy (TRUS-Pbx). MRI is an accurate diagnostic tool for AZ tumors, but is often unavailable due to cost or system restrictions. We examined the diagnostic yield of office based AZ TRUS-Pbx. 127 men at risk for AZ tumors were studied: Patients with elevated PSA and previous extended negative TRUS-Pbx (group 1, n = 78) and actively surveyed low risk prostate cancer patients (group 2, n = 49). None of the participants had a previous AZ biopsy. Biopsy template included suspicious ultrasonic areas, 16 peripheral zone (PZ), 4 transitional zone (TZ) and 6 AZ cores. All biopsies were performed by a single urologist under local peri-prostatic anaesthetic, using the B-K Medical US System, an end-firing probe 4-12 MHZ and 18 ga/25 cm needle. All samples were reviewed by a single specialized uro-pathologist. Multivariate analysis was used to detect predictors for AZ tumors accounting for age, PSA, PSA density, prostate volume, BMI, and number of previous biopsies. Median PSA was 10.4 (group 1) and 7.3 (group 2). Age (63.9, 64.5), number of previous biopsies (1.5) and cores (17.8, 21.3) and prostate volume (56.4 cc, 51 cc) were similar for both groups. The overall diagnostic yield was 34.6% (group 1) and 85.7% (group 2). AZ cancers were detected in 21.8% (group 1) and 34.7% (group 2) but were rarely the only zone involved (1.3% and 4.1% respectively). Gleason ≥ 7 AZ cancers were often accompanied by equal grade PZ tumors. In multivariate analysis only prostate volume predicted for AZ tumors. Patients detected with AZ tumors had significantly smaller prostates (36.9 cc vs. 61.1 cc p < 0.001). Suspicious AZ ultrasonic findings were uncommon (6.3%). TRUS-Pbx AZ sampling rarely improves the diagnostic yield of extended PZ sampling in patients with elevated PSA and previous negative biopsies. In low risk prostate cancer patients who are followed by active surveillance, AZ sampling changes risk stratification in 6% but larger studies are needed to define the role of AZ sampling in this population and its correlation with prostatectomy final pathological specimens.
2013-01-01
Background Operative delivery procedures, such as primary cesarean section, vacuum-assisted, and forceps-assisted vaginal delivery increase maternal and fetal morbidity, and the cost of care. We evaluated whether large fetal head circumference (FHC) independently increases risk of such interventions, as well as fetal distress or low Apgar score, in anatomically normal infants. Methods We conducted a population-based retrospective cohort study using Washington State birth certificate data. We included singleton, term infants born to nulliparous mothers from 2003–2009. We compared mode of delivery and fetal outcomes in 10,750 large-FHC (37-41 cm) infants relative to 10,750 average-FHC (34 cm) infants, frequency matched by birth-year. Results Large-FHC infants were nearly twice as likely to be delivered by primary cesarean section as average-FHC infants (unadjusted relative risk [RR] 1.84, 95% confidence interval [CI]: 1.77, 1.92). The RR for primary cesarean section associated with large-FHC was largest for mothers aged 19 years or less (RR 2.28; 95% CI: 1.99, 2.61), and smallest for mothers aged 35 years or greater (RR 1.51; 95% CI: 1.37, 1.66) [test of homogeneity, p < 0.001]. Large-FHC infants were at increased risk of vacuum-assisted vaginal delivery (RR 1.55; 95% CI: 1.43, 1.69), and forceps-assisted vaginal delivery (RR 1.61; 95% CI: 1.32, 1.97). There was no difference in risk of fetal distress (RR 0.97; 95% CI: 0.89, 1.07) for large-FHC versus average-FHC infants. Risk estimates were unaffected by adjustment for potential confounders. Conclusions Nulliparous mothers of large-FHC infants are at increased risk of primary cesarean section, vacuum-assisted and forceps-assisted vaginal delivery relative to mothers of average-FHC infants. Maternal age modifies the association between FHC and primary cesarean section. PMID:23651454
Shoji, Sunao; Hiraiwa, Shinichiro; Endo, Jun; Hashida, Kazunobu; Tomonaga, Tetsuro; Nakano, Mayura; Sugiyama, Tomoko; Tajiri, Takuma; Terachi, Toshiro; Uchida, Toyoaki
2015-02-01
To report our early experience with manually controlled targeted biopsy with real-time multiparametric magnetic resonance imaging and transrectal ultrasound fusion images for the diagnosis of prostate cancer. A total of 20 consecutive patients suspicious of prostate cancer at the multiparametric magnetic resonance imaging scan were recruited prospectively. Targeted biopsies were carried out for each cancer-suspicious lesion, and 12 systematic biopsies using the BioJet system. Pathological findings of targeted and systematic biopsies were analyzed. The median age of the patients was 70 years (range 52-83 years). The median preoperative prostate-specific antigen value was 7.4 ng/mL (range 3.54-19.9 ng/mL). Median preoperative prostate volume was 38 mL (range 24-68 mL). The number of cancer-detected cases was 14 (70%). The median Gleason score was 6.5 (range 6-8). Cancer-detected rates of the systematic and targeted biopsy cores were 6.7 and 31.8%, respectively (P < 0.0001). In six patients who underwent radical prostatectomy, the geographic locations and pathological grades of clinically significant cancers and index lesions corresponded to the pathological results of the targeted biopsies. Prostate cancers detected by targeted biopsies with manually controlled targeted biopsy using real-time multiparametric magnetic resonance imaging and transrectal ultrasound fusion imaging have significantly higher grades and longer length compared with those detected by systematic biopsies. Further studies and comparison with the pathological findings of whole-gland specimens have the potential to determine the role of this biopsy methodology in patients selected for focal therapy and those under active surveillance. © 2014 The Japanese Urological Association.
Eriksson, Mikael; Reichardt, Peter; Sundby Hall, Kirsten; Schütte, Jochen; Cameron, Silke; Hohenberger, Peter; Bauer, Sebastian; Leinonen, Mika; Reichardt, Annette; Rejmyr Davis, Maria; Alvegård, Thor; Joensuu, Heikki
2016-05-01
Preoperative percutaneous transabdominal wall biopsy may be considered to diagnose gastrointestinal stromal tumour (GIST) and plan preoperative treatment with tyrosine kinase inhibitors when an endoscopic biopsy is not possible. Hypothetically, a transabdominal wall biopsy might lead to cell seeding and conversion of a local GIST to a disseminated one. We investigated the influence of preoperative needle biopsy on survival outcomes. We collected the clinical data from hospital case records of the 397 patients who participated in the Scandinavian Sarcoma Group (SSG) XVIII/Arbeitsgemeinschaft Internistische Onkologie (AIO) randomised trial and who had a transabdominal fine needle and/or core needle biopsy carried out prior to study entry. The SSG XVIII/AIO trial compared 1 and 3 years of adjuvant imatinib in a patient population with a high risk of GIST recurrence after macroscopically radical surgery. The primary end-point was recurrence-free survival (RFS), and the secondary end-points included overall survival (OS). A total of 47 (12.0%) out of the 393 patients with data available underwent a percutaneous biopsy. No significant difference in RFS or OS was found between the patients who underwent or did not undergo a percutaneous biopsy either in the entire series or in subpopulation analyses, except for a statistically significant RFS advantage for patients who had a percutaneous biopsy and a tumour ≥10 cm in diameter. A preoperative diagnostic percutaneous biopsy of a suspected GIST may not increase the risk for GIST recurrence in a patient population who receive adjuvant imatinib after the biopsy. Copyright © 2016 Elsevier Ltd. All rights reserved.
Stewart, Grant D; Van Neste, Leander; Delvenne, Philippe; Delrée, Paul; Delga, Agnès; McNeill, S Alan; O'Donnell, Marie; Clark, James; Van Criekinge, Wim; Bigley, Joseph; Harrison, David J
2013-03-01
Concern about possible false-negative prostate biopsy histopathology findings often leads to rebiopsy. A quantitative methylation specific polymerase chain reaction assay panel, including GSTP1, APC and RASSF1, could increase the sensitivity of detecting cancer over that of pathological review alone, leading to a high negative predictive value and a decrease in unnecessary repeat biopsies. The MATLOC study blindly tested archived prostate biopsy needle core tissue samples of 498 subjects from the United Kingdom and Belgium with histopathologically negative prostate biopsies, followed by positive (cases) or negative (controls) repeat biopsy within 30 months. Clinical performance of the epigenetic marker panel, emphasizing negative predictive value, was assessed and cross-validated. Multivariate logistic regression was used to evaluate all risk factors. The epigenetic assay performed on the first negative biopsies of this retrospective review cohort resulted in a negative predictive value of 90% (95% CI 87-93). In a multivariate model correcting for patient age, prostate specific antigen, digital rectal examination and first biopsy histopathological characteristics the epigenetic assay was a significant independent predictor of patient outcome (OR 3.17, 95% CI 1.81-5.53). A multiplex quantitative methylation specific polymerase chain reaction assay determining the methylation status of GSTP1, APC and RASSF1 was strongly associated with repeat biopsy outcome up to 30 months after initial negative biopsy in men with suspicion of prostate cancer. Adding this epigenetic assay could improve the prostate cancer diagnostic process and decrease unnecessary repeat biopsies. Copyright © 2013 American Urological Association Education and Research, Inc. Published by Elsevier Inc. All rights reserved.
Core needle biopsy guidance based on EMOCT imaging (Conference Presentation)
NASA Astrophysics Data System (ADS)
Iftimia, Nicusor V.; Park, Jesung; Maguluri, Gopi
2016-03-01
We present a novel method, based on encoder mapping OCT imaging, for real-time guidance of core biopsy procedures. This method provides real-time feedback to the interventional radiologist, such that he/she can reorient the needle during the biopsy and sample the most representative area of the suspicious mass that is being investigated. This aspect is very important for tailoring therapy to the specific cancer based on biomarker analysis, which will become one of the next big advances in our search for the optimal cancer therapy. To enable individualized treatment, the genetic constitution and the DNA repair status in the affected areas is needed for each patient. Thus, representative sampling of the tumor is needed for analyzing various biomarkers, which are used as a tool to personalize cancer therapy. The encoder-based OCT enables samping of large size masses and provides full control on the imaging probe, which is passed through the bore of the biopsy guidance needle. The OCT image is built gradually, based on the feedback of an optical encoder which senses the incremental movement of the needle with a few microns resolution. Tissue mapping is independent of the needle speed, while it is advanced through the tissue. The OCT frame is analyzed in real-time and tissue cellularity is reported in a very simple manner (pie chart). Our preliminary study on a rabbit model of cancer has demonstrated the capability of this technology for accurately differentiating between viable cancer and heterogeneous or necrotic tissue.
Serial Magnetic Resonance Imaging in Active Surveillance of Prostate Cancer: Incremental Value.
Felker, Ely R; Wu, Jason; Natarajan, Shyam; Margolis, Daniel J; Raman, Steven S; Huang, Jiaoti; Dorey, Fred; Marks, Leonard S
2016-05-01
We assessed whether changes in serial multiparametric magnetic resonance imaging can help predict the pathological progression of prostate cancer in men on active surveillance. A retrospective cohort study was conducted of 49 consecutive men with Gleason 6 prostate cancer who underwent multiparametric magnetic resonance imaging at baseline and again more than 6 months later, each followed by a targeted prostate biopsy, between January 2011 and May 2015. We evaluated whether progression on multiparametric magnetic resonance imaging (an increase in index lesion suspicion score, increase in index lesion volume or decrease in index lesion apparent diffusion coefficient) could predict pathological progression (Gleason 3 + 4 or greater on subsequent biopsy, in systematic or targeted cores). Diagnostic performance of multiparametric magnetic resonance imaging was determined with and without clinical data using a binary logistic regression model. The mean interval between baseline and followup multiparametric magnetic resonance imaging was 28.3 months (range 11 to 43). Pathological progression occurred in 19 patients (39%). The sensitivity, specificity, positive predictive value and negative predictive value of multiparametric magnetic resonance imaging was 37%, 90%, 69% and 70%, respectively. Area under the receiver operating characteristic curve was 0.63. A logistic regression model using clinical information (maximum cancer core length greater than 3 mm on baseline biopsy or a prostate specific antigen density greater than 0.15 ng/ml(2) at followup biopsy) had an AUC of 0.87 for predicting pathological progression. The addition of serial multiparametric magnetic resonance imaging data significantly improved the AUC to 0.91 (p=0.044). Serial multiparametric magnetic resonance imaging adds incremental value to prostate specific antigen density and baseline cancer core length for predicting Gleason 6 upgrading in men on active surveillance. Copyright © 2016 American Urological Association Education and Research, Inc. Published by Elsevier Inc. All rights reserved.
Pearce, Shane M; Wang, Chi-Hsiung E; Victorson, David E; Helfand, Brian T; Novakovic, Kristian R; Brendler, Charles B; Albaugh, Jeffrey A
2015-09-01
The aim of this study was to examine the relationship between sexual dysfunction, repeat biopsies and other demographic and clinical factors in men on active surveillance (AS). Patient-reported outcomes (PROs) measures were administered at enrollment and every 6 months to assess quality of life (QOL), psychosocial and urological health outcomes. Using mixed-effects models, we examined the impact of repeat biopsies, total number of cores taken, anxiety, age, and comorbidity on sexual function over the first 24 months of enrolling in AS. PROs included the Expanded Prostate Cancer Index Composite-26 (EPIC-26) Sexual Function (SF) subscale, the American Urological Association-Symptom Index (AUA-SI), and the Memorial Anxiety Scale for Prostate Cancer (MAX-PC). At enrollment (n = 195), mean age was 66.5 ± 6.8 with a mean EPIC-26 SF score of 61.4 ± 30.4. EPIC-26 SF scores steadily decreased to 53.9 ± 30.7 at 24 months (P < 0.01). MAX-PC scores also progressively decreased over time (P = 0.03). Factors associated with lower EPIC-26 scores over time included age, unemployed status, diabetes, coronary artery disease, and hypertension (all P < 0.05). Higher prostate-specific antigen (PSA) was associated with a more rapid decline in EPIC-26 SF over time (P = 0.03). In multivariable analysis, age, diabetes, and PSA × time interaction remained significant predictors of diminished sexual function. Anxiety, number of biopsies, and total cores taken did not predict sexual dysfunction or change over time in our cohort. Men on AS experienced a gradual decline in sexual function during the first 24 months of enrollment. Older age, PSA × time, and diabetes were all independent predictors of diminished sexual function over time. Anxiety, AUA-SI, the number of cores and the number of biopsies were not predictors of reduced sexual function in men in AS.
Risk Factors for the Development of Obstetric Anal Sphincter Injuries in Modern Obstetric Practice.
Ramm, Olga; Woo, Victoria G; Hung, Yun-Yi; Chen, Hsuan-Chih; Ritterman Weintraub, Miranda L
2018-02-01
To characterize the rate of obstetric anal sphincter injuries and identify key risk factors of obstetric anal sphincter injuries, including duration of the second stage of labor. This retrospective cohort study included all singleton, term, cephalic vaginal deliveries within Kaiser Permanente Northern California between January 2013 and December 2014 (N=22,741). Incidence of obstetric anal sphincter injuries, defined as third- or fourth-degree perineal lacerations, was the primary outcome. Multiple logistic regression models were conducted to identify obstetric anal sphincter injury risk factors and high-risk subpopulations. The overall incidence rate of obstetric anal sphincter injuries was 4.9% (3.6% of women who delivered spontaneously vs 24.0% of women who had a vacuum-assisted vaginal delivery, P<.001, CI 18.1-22.6%). In bivariate and multivariate analyses, obstetric anal sphincter injury incidence was higher among women with second stage of labor longer than 2 hours, Asian race, nulliparity, vaginal birth after cesarean delivery, episiotomy, and vacuum delivery. Women with a vacuum-assisted vaginal delivery had four times the odds of obstetric anal sphincter injury (adjusted odds ratio [OR] 4.23, 95% CI 3.59-4.98) and those whose second stage of labor lasted at least 180 minutes vs less than 60 minutes had three times the odds of incurring obstetric anal sphincter injury (adjusted OR 3.20, 95% CI 2.62-3.89). Vacuum-assisted vaginal delivery conferred the highest odds of obstetric anal sphincter injury followed by prolonged duration of the second stage of labor, particularly among certain subpopulations. Understanding these risk factors and their complex interactions can inform antepartum and intrapartum decision-making with the goal of reducing obstetric anal sphincter injury incidence.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Schlueter, R.D.; Halbach, K.
1991-12-04
This memo presents the formulation of an expression for eddy currents induced in a thin-walled conductor due to a time-dependent electromagnet field excitation. Then follows an analytical development for prediction of vacuum chamber eddy current induced field harmonics in iron-core electromagnets. A passive technique for harmonics suppression is presented with specific application to the design of the Superconducting Super Collider (SSC) Low Energy B (LEB) Magnets.
Coeliac disease: the histology report.
Villanacci, Vincenzo; Ceppa, Paola; Tavani, Enrico; Vindigni, Carla; Volta, Umberto
2011-03-01
To this day intestinal biopsy is justly considered the "gold standard" for the diagnosis of coeliac disease (CD). The aim of the authors in setting up these guidelines was to assist pathologists in formulating a more precise morphological evaluation of a duodenal biopsy in the light of clinical and laboratory data, to prepare histological samples with correctly oriented biopsies and in the differential diagnosis with other pathological entities and complications of the disease. A further intention was to promote the conviction for the need of a close collaborative relationship between different specialists namely the concept of a "multidisciplinary team". Copyright © 2011 Editrice Gastroenterologica Italiana S.r.l. Published by Elsevier Ltd.. All rights reserved.
NASA Astrophysics Data System (ADS)
Kim, Han-Jung; Lee, Sang Eon; Lee, Jihye; Jung, Joo-Yun; Lee, Eung-Sug; Choi, Jun-Hyuk; Jung, Jun-Ho; Oh, Minsub; Hyun, Seungmin; Choi, Dae-Geun
2014-07-01
We designed and fabricated a gold (Au)-coated silicon nanowires/graphene (Au-SiNWs/G) hybrid composite as a polymer binder-free anode for rechargeable lithium-ion batteries (LIBs). A large amount of SiNWs for LIB anode materials can be prepared by metal-assisted chemical etching (MaCE) process. The Au-SiNWs/G composite film on current collector was obtained by vacuum filtration using an anodic aluminum oxide (AAO) membrane and hot pressing method. Our experimental results show that the Au-SiNWs/G composite has a stable reversible capacity of about 1520 mA h/g which was maintained for 20 cycles. The Au-SiNWs/G composite anode showed much better cycling performance than SiNWs/polyvinylidene fluoride (PVDF)/Super-P, SiNWs/G composite, and pure SiNWs anodes. The improved electrochemical properties of the Au-SiNWs/G composite anode material is mainly ascribed to the composite's porous network structure.
Energy Deposition and Condition of the Metal Core in Exploding Wire Experiments
NASA Astrophysics Data System (ADS)
Sarkisov, G. S.; Rosenthal, S. E.; Struve, K. W.; McDaniel, D. H.; Waisman, E. M.; Sasorov, P. V.
2002-11-01
Measurements of the Joule energy deposition into exploding wire and its relation with condition of the expanding wire core are presented. Wires of nine different metals with diameters of 10-30 microns, have been exploded by fast 150A/ns and slow 20A/ns pulses, in vacuum and in air. It has been shown by interferometry and light emission that expanding wire core has different conditions. The substances with small atomization enthalpy (Ag, Al, Cu, Au) demonstrate full vaporization of the wire core. The refractory metals (Ti, Pt, Mo, W) demonstrates that core consists from vapor and small and hot microparticles. In this case we observe "firework effect" when large radiation from the wire exceed the energy deposition time in a three order of magnitude. For non-refractory metals radiation dropping fast in 100 ns time scale due to effective adiabatic cooling. It is possible if main part of the metal core was vaporized. The interferometrical investigation of the refraction coefficient of expanding metal core is proof this conclusion. It has been shown that energy deposition before surface breakdown dependent strongly from current rate, surface coatings, environment, wire diameter and radial electric field. The regime of wire explosion in vacuum without shunting plasma shell has been realized for fast exploding mode. In this case we observe anomaly high energy deposition in to the wire core exceeding regular value in almost 20 times. The experimental results for Al wire have been compared with ALEGRA 2D MHD simulations. *Sandia is a multi-program laboratory operated by Sandia Corporation, a Lockheed Martin Company, for the United States Department of Energy under Contract DE-AC04-94AL8500.
Flat epithelial atypia of the breast: characteristics and behaviors.
Sudarshan, Monisha; Meguerditchian, Ari-Nareg; Mesurolle, Benoit; Meterissian, Sarkis
2011-02-01
Flat epithelial atypia (FEA) increasingly is being recognized as a pathologic entity on core needle biopsies. However, definitive management of this columnar cell lesion remains debatable because its malignant potential is unknown. A PubMed search for "flat epithelial atypia" and "columnar cell lesions" was performed. FEA commonly was encountered in the background of higher-grade lesions such as atypical ductal hyperplasia, ductal carcinoma in situ, and tubular and lobular carcinomas. Its molecular and cytogenetic profile revealed some alterations similar to precancerous lesions. Pure FEA on core needle biopsies was upgraded to higher-grade lesions on subsequent surgical excision. Current management of FEA is best achieved through a multidisciplinary review considering various factors to determine if surgical excision is warranted. Further studies are required to elucidate the malignant potential of this columnar cell lesion. Copyright © 2011 Elsevier Inc. All rights reserved.