Sample records for vacuum-assisted venous drainage

  1. Vacuum-assisted venous return reduces blood usage.

    PubMed

    Banbury, Michael K; White, Jennifer A; Blackstone, Eugene H; Cosgrove, Delos M

    2003-09-01

    To determine whether vacuum-assisted venous return has clinical advantages over conventional gravity drainage apart from allowing the use of smaller cannulas and shorter tubing. A total of 150 valve operations were performed at our institution between February and July 1999 using vacuum-assisted venous return with small venous cannulas connected to short tubing. These were compared with (1) 83 valve operations performed between April 1997 and January 1998 using the initial version of vacuum-assisted venous return, and (2) 124 valve operations performed between January and April of 1997 using conventional gravity drainage. Priming volume, hematocrit value, red blood cell usage, and total blood product usage were compared multivariably. These comparisons were covariate and propensity adjusted for dissimilarities between the groups and confirmed by propensity-matched pairs analysis. Priming volume was 1.4 +/- 0.4 L for small-cannula vacuum-assisted venous return, 1.7 +/- 0.4 L for initial vacuum-assisted venous return, and 2.0 +/- 0.4 L for gravity drainage (P <.0001). Smaller priming resulted in higher hematocrit values both at the beginning of cardiopulmonary bypass (27% +/- 5% compared with 26% +/- 4% and 25% +/- 4%, respectively, P <.0001) and at the end (30% +/- 4% compared with 28% +/- 4% and 27% +/- 4%, respectively, P <.0001). Red cell transfusions were used in 17% of the patients having small-cannula vacuum-assisted venous return, 27% of the initial patients having vacuum-assisted venous return, and 37% of the patients having gravity drainage (P =.001); total blood product usage was 19%, 27%, and 39%, respectively (P =.002). Although ministernotomy also was associated with reduced blood product usage (P <.004), propensity matching on type of sternotomy confirmed the association of vacuum-assisted venous return with lowered blood product usage. Vacuum-assisted venous return results in (1) higher hematocrit values during cardiopulmonary bypass and (2) decreased

  2. Can Vacuum Assisted Venous Drainage be Achieved using a Roller Pump in an Emergency? A Pilot Study using Neonatal Circuitry

    PubMed Central

    Hill, S. L.; Holt, D. W.

    2007-01-01

    Abstract: There has been much advancement in perfusion technology over its 50 years of progression. One of these techniques is vacuum-assisted venous drainage (VAVD). Many perfusionists augment venous drainage using VAVD, typically from a wall vacuum source. This study explores alternates to providing VAVD if the wall vacuum fails. In two porcine laboratories, ∼36 in. of 3/16-in. tubing was connected to a sucker return port and placed into the roller head next to the arterial pump. The vacuum was monitored with a DLP pressure monitoring system (Medtronic). This system was connected to small-bore tubing and attached to a stopcock on top of the reservoir. The vacuum was regulated using another stopcock connected to a non-filtered luer lock port on top of the reservoir or by a segment of 3 × 0.25-in.-diameter tubing attached to the vent port with a c-clamp. Vacuum drainage was achieved, ranging from −18 mmHg to −71 mmHg by manipulating the stopcock or c-clamp. Changes in venous drainage were seen by volume fluctuations in the venous reservoir. The vacuum was adjusted to account for dramatic changes. Augmented venous drainage using a roller pump can be achieved successfully during cardiopulmonary bypass (CPB). This method of active drainage can be used in lieu of wall suction or during times of emergency if wall suction fails. PMID:18293812

  3. Effect of Vacuum on Venous Drainage: an Experimental Evaluation on Pediatric Venous Cannulas and Tubing Systems.

    PubMed

    Vida, V L; Bhattarai, A; Speggiorin, S; Zanella, F; Stellin, G

    2014-01-01

    To observe how vacuum assisted venous drainage (VAVD) may influence the flow in a cardiopulmonary bypass circuit with different size of venous lines and cannulas. The experimental circuit was assembled to represent the cardiopulmonary bypass circuit routinely used during cardiac surgery. Wall suction was applied directly, modulated and measured into the venous reservoir. The blood flow was measured with a flow-meter positioned on the venous line. The circuit prime volume was replaced with group O date expired re-suspended red cells and Plasmalyte 148 to a hematocrit of 28% to 30%. In an open circuit with gravity siphon venous drain, angled cannulae drain more than straight ones regardless the amount of suction applied to the venous line (16 Fr straight cannula (S) drains 90 ml/min less than a 16 Fr angled (A) with a siphon gravity). The same flow can be obtained with lower cannula size and higher suction (i.e. 12 A with and -30 mmHg). Tables have been created to list how the flow varies according to the size of the cannulas, the size of the venous tubes, and the amount of suction applied to the system. Vacuum assisted venous drainage allows the use of smaller cannulae and venous lines to maintain a good venous return, which is very useful during minimally invasive approaches. The present study should be considered as a preliminary attempt to create a scientific-based starting point for a uniform the use of VAVD.

  4. Vacuum-assisted drainage in cardiopulmonary bypass: advantages and disadvantages

    PubMed Central

    de Carvalho Filho, Élio Barreto; Marson, Fernando Augusto de Lima; da Costa, Loredana Nilkenes Gomes; Antunes, Nilson

    2014-01-01

    Systematic review of vacuum assisted drainage in cardiopulmonary bypass, demonstrating its advantages and disadvantages, by case reports and evidence about its effects on microcirculation. We conducted a systematic search on the period 1997-2012, in the databases PubMed, Medline, Lilacs and SciELO. Of the 70 selected articles, 26 were included in the review. Although the vacuum assisted drainage has significant potential for complications and requires appropriate technology and professionalism, prevailed in literature reviewed the concept that vacuum assisted drainage contributed in reducing the rate of transfusions, hemodilutions, better operative field, no significant increase in hemolysis, reduced complications surgical, use of lower prime and of smaller diameter cannulas. PMID:25140478

  5. Vacuum-assisted drainage in cardiopulmonary bypass: advantages and disadvantages.

    PubMed

    Carvalho Filho, Elio Barreto de; Marson, Fernando Augusto de Lima; Costa, Loredana Nilkenes Gomes da; Antunes, Nilson

    2014-01-01

    Systematic review of vacuum assisted drainage in cardiopulmonary bypass, demonstrating its advantages and disadvantages, by case reports and evidence about its effects on microcirculation. We conducted a systematic search on the period 1997-2012, in the databases PubMed, Medline, Lilacs and SciELO. Of the 70 selected articles, 26 were included in the review. Although the vacuum assisted drainage has significant potential for complications and requires appropriate technology and professionalism, prevailed in literature reviewed the concept that vacuum assisted drainage contributed in reducing the rate of transfusions, hemodilutions, better operative field, no significant increase in hemolysis, reduced complications surgical, use of lower prime and of smaller diameter cannulas.

  6. Hemolysis During Open-Heart Surgery With Vacuum-Assisted Venous Drainage at Different Negative Pressures in Pediatric Patients Weighing Less Than 10 kilograms.

    PubMed

    Kwak, Jae Gun; Lee, Jinkwon; Park, Minkyoung; Seo, Yu-Jin; Lee, Chang-Ha

    2017-03-01

    This study examined the degree of hemolysis during vacuum-assisted venous drainage at different negative pressures to identify an adequate negative pressure that provides effective venous drainage without significant hemolysis in open-heart surgery in children weighing less than 10 kg. Patients weighing less than 10 kg who underwent surgery for ventricular septal defect or atrial septal defect from 2011 to 2014 were enrolled. We used one of four negative pressures (20, 30, 40, or 60 mm Hg) for each patient. We measured haptoglobin, plasma hemoglobin, aspartate aminotransferase, and lactate dehydrogenase levels in the patients' blood three times perioperatively and determined the potential correlation between the change in each parameter with the level of negative pressure. Forty-six patients were enrolled in this study (mean age: 7.1 ± 7.0 months, mean body weight: 6.1 ± 1.8 kg). There were no significant differences according to the degree of negative pressure with respect to patient age, body weight, cardiopulmonary bypass (CPB) time, aorta cross-clamping time, blood flow during CPB, or lowest body temperature. All parameters that we measured reflected progression of hemolysis during CPB; however, the degree of change in the parameters did not correlate with negative pressure. In pediatric patients weighing less than 10 kg, the change in the degree of hemolysis did not differ with the amount of negative pressure. We may apply negative pressures up to 60 mm Hg without increasing the risk of hemolysis, with almost same the level of hemolysis using negative pressures of 20, 30, and 40 mm Hg for effective venous drainage and an ideal operative field during open-heart surgery.

  7. Resection of giant right atrial lymphoma using vacuum-assisted cardiopulmonary bypass without snaring the inferior vena cava.

    PubMed

    Shin, Hankei; Mori, Mitsuharu; Matayoshi, Toru; Suzuki, Ryo; Yozu, Ryohei

    2004-08-01

    A 53-year-old man sustained hemodynamic collapse due to a huge right atrial tumor and was transferred to our hospital and underwent a life-saving emergency operation. The tumor arose from the inferolateral wall of the right atrium, occupying almost the whole right atrial cavity and obstructing not only the inflow of the right ventricle but also the orifice of the inferior vena cava. Venous cannulation via the right atrial wall and placing a snare around the inferior vena cava were impossible. With a cardiopulmonary bypass using vacuum-assisted venous drainage, the tumor was successfully resected and the tricuspid valve was replaced with a bioprosthetic valve without snaring the inferior vena cava. Postoperative histological examination demonstrated the tumor to be a large B-cell non-Hodgkin type malignant lymphoma. When the tumor is large and it is difficult to establish total cardiopulmonary bypass, the vacuum-assisted cardiopulmonary bypass is a useful option. This can achieve a bloodless operative field and is not blocked by the incoming air, due to the venous drainage being continually pressure-regulated.

  8. Systemic venous drainage: can we help Newton?

    PubMed

    Corno, Antonio F

    2007-06-01

    In recent years substantial progress occurred in the techniques of cardiopulmonary bypass, but the factor potentially limiting the flexibility of cardiopulmonary bypass remains the drainage of the systemic venous return. In the daily clinical practice of cardiac surgery, the amount of systemic venous return on cardiopulmonary bypass is directly correlated with the amount of the pump flow. As a consequence, the pump flow is limited by the amount of venous return that the pump is receiving. On cardiopulmonary bypass the amount of venous drainage depends upon the central venous pressure, the height differential between patient and inlet of the venous line into the venous reservoir, and the resistance in the venous cannula(s) and circuit. The factors determining the venous return to be taken into consideration in cardiac surgery are the following: (a) characteristics of the individual patient; (b) type of planned surgical procedure; (c) type of venous cannula(s); (d) type of circuit for cardiopulmonary bypass; (e) strategy of cardiopulmonary bypass; (f) use of accessory mechanical systems to increased the systemic venous return. The careful pre-operative evaluation of all the elements affecting the systemic venous drainage, including the characteristics of the individual patient and the type of required surgical procedure, the choice of the best strategy of cardiopulmonary bypass, and the use of the most advanced materials and tools, can provide a systemic venous drainage substantially better than what it would be allowed by the simple "Law of universal gravitation" by Isaac Newton.

  9. The complicated role of venous drainage on the survival of arterialized venous flaps

    PubMed Central

    Weng, Weidong; Zhang, Feng; Zhao, Bin; Wu, Zhipeng; Gao, Weiyang; Li, Zhijie; Yan, Hede

    2017-01-01

    The arterialized venous flap (AVF) has been gradually popularized in clinical settings; however, its survival is still inconsistent and the role of venous drainage remains elusive. In this study, we aimed to investigate the role of venous drainage on the flap survival of arterialized venous flaps. An arterialized venous flap was outlined symmetrically in the rabbit abdomen. The arterial perfusion flap with a unilateral vascular pedicle was taken as the control group and three other experimental groups (I, II and III) were designed based on the number of drainage veins (n = 1, 2 and 3 in the three groups, respectively). Compared with the control group, significant venous congestion was noted in all the experimental groups and the most severe one was seen in group I; while no statistical difference was observed between groups II and III. Similar results regarding blood perfusion state, epidermal metabolite levels and flap survival status were obtained among the three groups. These findings suggested that venous drainage is vital in the survival of the flap, but unlike in the arterial perfusion flaps, the problem of venous congestion can only be partially solved by increasing the number of draining veins. Further studies are warranted to gain insight into this complicated issue. PMID:28145882

  10. Patterns and Rates of Supplementary Venous Drainage to the Internal Jugular Veins.

    PubMed

    Qureshi, Adnan I; Ishfaq, Muhammad Fawad; Herial, Nabeel A; Khan, Asif A; Suri, M Fareed K

    2016-07-01

    Several studies have found supplemental venous drainage channels in addition to bilateral internal jugular veins for cerebral venous efflux. We performed this study to characterize the supplemental venous outflow patterns in a consecutive series of patients undergoing detailed cerebral angiography with venous phase imaging. The venographic phase of the arteriogram was reviewed to identify and classify supplemental cerebral venous drainage into anterior (cavernous venous sinus draining into pterygoid plexus and retromandibular vein) and posterior drainage pattern. The posterior drainage pattern was further divided into plexiform pattern (with sigmoid venous sinus draining into the paravertebral venous plexus), and solitary vein pattern (dominant single draining deep cervical vein) drainage. The posterior plexiform pattern was further divided into 2 groups: posterior plexiform with or without prominent solitary vein. Supplemental venous drainage was seen ipsilateral to internal jugular vein in 76 (43.7%) of 174 venous drainages (87 patients) analyzed. The patterns were anterior (n = 23, 13.2%), posterior plexiform without prominent solitary vein (n = 40, 23%), posterior plexiform with prominent solitary vein (n = 62, 35.6%), and posterior solitary vein alone (n = 3, 1.7%); occipital emissary veins and/or transosseous veins were seen in 1 supplemental venous drainage. Concurrent ipsilateral anterior and posterior supplemental drainage was seen in 6 of 174 venous drainages analyzed. We provide an assessment of patterns and rates of supplementary venous drainage to internal jugular veins to improve our understanding of anatomical and physiological aspects of cerebral venous drainage. Copyright © 2016 by the American Society of Neuroimaging.

  11. [Application research of presacral space drainage tube combined with subcutaneous vacuum pressure suction in the laparoscopic-assisted abdominoperineal resection].

    PubMed

    Chen, Liqi; Zeng, Changqing; Chi, Liangjie; Huang, Liangxiang; Li, Jiandang

    2017-08-25

    To study the management for the perineal incision after laparoscopic-assisted abdominoperineal resection for rectal cancer. Clinical data of 87 patients undergoing laparoscopic Miles operation for lower rectal cancer from June 2009 to February 2014 were collected and studied. Presacral space drainage group: presacral space drainage tube was applied in 42 patients. Combined drainage group: presacral space drainage tube combined with subcutaneous vacuum pressure suction was applied in 45 cases. In combined drainage group, except the presacral drainage tube, another drainage tube was placed subcutaneously and connected to a negative pressure ball, which was fixed on the lateral anterior of perineal wound by the further incision and drainage. After subcutaneous tube was placed for 2 weeks, as drainage fluid was limpid and <15 ml/d for 3 days, meanwhile no obvious pelvic fluid was detected by ultrasound, and the wound healed quite well without redness and edema, then the subcutaneous tube with the negative pressure ball could be removed. There were 51 males and 36 females with the mean age of 26-78(56.9±10.8) years old. The laparoscopic Miles operation was successfully completed in all the cases without death and complications. The drainage tube was placed for 4-13(8.0±2.5) days in presacral space drainage group, and for 4-14(6.7±2.4) days in combined drainage group. The subcutaneous tube was placed for 14-24(15.8±3.0) days. The primary healing rate of perineal wound in presacral space drainage group and combined drainage group was 66.7%(28/42) and 91.1%(41/45) respectively, while the perineal wound infection rate was 21.4%(9/42) and 4.4%(2/45) respectively, whose differences between two groups were both significant (χ 2 =7.911, P=0.005 and χ 2 =5.674, P=0.017). Presacral space drainage tube combined with subcutaneous vacuum pressure suction in laparoscopic-assisted abdominoperineal resection for rectal cancer has better efficacy and lower infection rate for

  12. Patterns of anomalous pulmonary venous drainage.

    PubMed

    Snellen, H A; van Ingen, H C; Hoefsmit, E C

    1968-07-01

    All of our cases of abnormal pulmonary venous connections collected to the middle of 1965 and verified at surgery or autopsy have been reviewed by means of diagrams and tabulations, using a specially devised code to facilitate the survey. The material consisted of 52 autopsy cases (half of them obtained after surgery) and the cases of 72 patients who survived operation. The postmortem group was much younger than the surgical group and differed also from the latter by showing male preponderance as well as relatively many instances of total abnormal pulmonary venous connection and frequently associated cardiac anomalies. Partial anomalous connection of right pulmonary veins was 10 times more frequent than that of the left pulmonary veins. This was caused by (1) the frequent drainage of some of the right pulmonary veins into the junctional area between right atrium and superior vena cava in the presence of normal left pulmonary veins, and (2) the complete absence of isolated left pulmonary venous connection to the right atrium. Abnormal connection of solitary pulmonary veins was always effected to the most proximal venous structure among the four possible ones which are derived from the main embryonic channels (superior vena cava and inferior vena cava on the right side, and left superior vena cava and coronary sinus on the left side). Common pulmonary veins from one lung also drained in accordance with this proximity rule, if this may be taken to apply also to the drainage of right pulmonary veins into the right atrium. The one exception in our material was the drainage of all right pulmonary veins into the portal venous system. Total abnormal pulmonary venous connection may be found with all structures mentioned, but most frequently with the left superior vena cava, or coronary sinus, or both, usually by way of a common pulmonary vein. In a few cases however, drainage into different sites, all of them abnormal, did occur. Then again the proximity rule seemed to

  13. Proximally pedicled medial plantar flap based on superficial venous system alone for venous drainage.

    PubMed

    Wright, Thomas C; Mossaad, Bassem M; Chummun, Shaheel; Khan, Umraz; Chapman, Thomas W L

    2013-07-01

    The proximally pedicled medial plantar flap is well described for coverage of wounds around the ankle and heel. This flap is usually based on the deep venae comitantes for venous drainage, with the superficial veins divided during dissection. Usually any disruption of the deep venous system of the flap would result in abandoning this choice of flap. Venous congestion is a recognised complication of medial plantar flaps. The patient described in this case report had a medial ankle defect with exposed bone, for which a proximally pedicled medial plantar flap was used. As we raised the flap, both venae comitantes of the medial planter artery were found to be disrupted. The flap was raised based on the superficial veins draining into the great saphenous, as the only system for venous drainage, with no evidence of venous congestion. The flap was successfully transposed into the defect and healed with no complications. The proximally pedicled medial plantar flap can safely rely on the superficial venous system alone for drainage. In addition, preserving the superficial veins minimise the risk of venous congestion in this flap. We recommend preservation of superficial venous system when possible. Copyright © 2013 British Association of Plastic, Reconstructive and Aesthetic Surgeons. Published by Elsevier Ltd. All rights reserved.

  14. Are there still roles for exocrine bladder drainage and portal venous drainage for pancreatic allografts?

    PubMed

    Young, Carlton J

    2009-02-01

    Controversy remains regarding the best methodology of handling exocrine pancreatic fluid and pancreatic venous effluent. Bladder drainage has given way to enteric drainage. However, is there an instance in which bladder drainage is preferable? Also, hyperinsulinemia, as a result of systemic venous drainage (SVD), is claimed to be proatherosclerotic, whereas portal venous drainage (PVD) is more physiologic and less atherosclerotic. Bladder drainage remains a viable method of exocrine pancreas drainage, but evidence is sparse that measuring urinary amylase has a substantial benefit in the early detection of acute rejection in all types of pancreas transplants. Currently, there is no incontrovertible evidence that systemic hyperinsulinemia is proatherosclerotic, whereas recent metabolic studies on SVD and PVD showed that there was no benefit to PVD. Given the advent of newer immunosuppressive agents and overall lower acute rejection rates, the perceived benefit of bladder drainage as a means to measure urinary amylase as an early marker of rejection has not been substantiated. However, there may be a selective role for bladder drainage in 'high risk' pancreases. Also, without a clear-cut metabolic benefit to PVD over SVD, it remains the surgeon's choice as to which method to use.

  15. Total anomalous systemic venous drainage in left heterotaxy syndrome.

    PubMed

    Khandenahally, Ravindranath S; Deora, Surender; Math, Ravi S

    2013-04-01

    Total anomalous systemic venous drainage is an extremely rare congenital heart defect. In this study we describe an 11-year-old girl who presented with a history of fatigue and central cyanosis that she had had since early childhood with unremarkable precordial examination results. Investigations revealed left heterotaxy with all systemic venous drainage to the left-sided atrium with non-compaction of the left ventricle.

  16. Intraatrial baffle repair of anomalous systemic venous return without hepatic venous drainage in heterotaxy syndrome.

    PubMed

    Turkoz, Riza; Ayabakan, Canan; Vuran, Can; Omay, Oğuz

    2010-08-01

    A 7-month-old boy with heterotaxy syndrome had partial atrioventricular septal defect and interrupted inferior vena cava with hemiazygos continuation to a left superior vena cava. The left side of the common atrium receiving all the venous drainage was in connection with the left ventricle and the aorta. The small atrium and the proximity of the pulmonary and hepatic vein orifices precluded complete baffling. This report describes an intraatrial baffle repair of anomalous systemic venous return without hepatic venous drainage. This resulted in good oxygenation postoperatively, with oxygen saturation ranging from 93% to 98%.

  17. Red rubber bulb, cheap and effective vacuum drainage.

    PubMed

    Vatanasapt, V; Areemit, S; Jeeravipoolvarn, P; Kuyyakanond, T; Kuptarnond, C

    1989-04-01

    Red rubber bulbs have been used for vacuum drainage in head, neck, breast and several other operations by the authors since 1975 quite effectively without any major problems. The vacuum pressure of the red rubber bulbs was found to be higher than the expensive commercially available vacuum wound drainage device. The question of remaining old blood and infective microorganisms inside the reservoir for the reused ones were tested by the manual cleaning process and the standard sterile technique using steam under increased pressure (autoclave). The result is quite satisfactory. We encourage the use of this cheap and effective (made in Thailand) vacuum wound drainage in Thai hospitals and Thai medical schools.

  18. Cranial dural arteriovenous shunts. Part 4. Clinical presentation of the shunts with leptomeningeal venous drainage.

    PubMed

    Baltsavias, Gerasimos; Spiessberger, Alex; Hothorn, Torsten; Valavanis, Anton

    2015-04-01

    Cranial dural arteriovenous fistulae have been classified into high- and low-risk lesions mainly based on the pattern of venous drainage. Those with leptomeningeal venous drainage carry a higher risk of an aggressive clinical presentation. Recently, it has been proposed that the clinical presentation should be considered as an additional independent factor determining the clinical course of these lesions. However, dural shunts with leptomeningeal venous drainage include a very wide spectrum of inhomogeneous lesions. In the current study, we correlated the clinical presentation of 107 consecutive patients harboring cranial dural arteriovenous shunts with leptomeningeal venous drainage, with their distinct anatomic and angiographic features categorized into eight groups based on the "DES" (Directness and Exclusivity of leptomeningeal venous drainage and features of venous Strain) concept. We found that among these groups, there are significant angioarchitectural differences, which are reflected by considerable differences in clinical presentation. Leptomeningeal venous drainage of dural sinus shunts that is neither direct nor exclusive and without venous strain manifested only benign symptoms (aggressive presentation 0%). On the other end of the spectrum, the bridging vein shunts with direct and exclusive leptomeningeal venous drainage and venous strain are expected to present aggressive symptoms almost always and most likely with bleeding (aggressive presentation 91.5%). Important aspects of the above correlations are discussed. Therefore, the consideration of leptomeningeal venous drainage alone, for prediction of the clinical presentation of these shunts appears insufficient. Angiographic analysis based on the above concept, offers the possibility to distinguish the higher- from the lower-risk types of leptomeningeal venous drainage. In this context, consideration of the clinical presentation as an additional independent factor for the prediction of their clinical

  19. Manual lymphatic drainage in chronic venous disease: a duplex ultrasound study.

    PubMed

    Dos Santos Crisóstomo, Rute Sofia; Candeias, Miguel Sandu; Ribeiro, Ana Margarida Martins; da Luz Belo Martins, Catarina; Armada-da-Silva, Paulo As

    2014-12-01

    To compare the effect of call-up and reabsorption maneuvers of manual lymphatic drainage on blood flow in femoral vein and great saphenous vein in patients with chronic venous disease and healthy controls. Forty-one subjects participated in this study (mean age: 42.68(15.23)), 23 with chronic venous disease (chronic venous disease group) with clinical classification C1-5 of clinical-etiological-anatomical-pathological (CEAP) and 18 healthy subjects (control group). Call-up and reabsorption maneuvers were randomly applied in the medial aspect of the thigh. The cross-sectional areas, as well as the peak and the mean blood flow velocity at femoral vein and great saphenous vein, were assessed by Duplex ultrasound at the baseline and during maneuvers. The venous flow volume changes were calculated. The venous flow volume in femoral vein and great saphenous vein increased during both manual lymphatic drainage maneuvers and in both groups (P < 0.05). The two maneuvers had a similar effect on femoral vein and great saphenous vein hemodynamics, and in both the chronic venous disease and control groups. As a result of the call-up maneuver, the flow volume augmentations, as a result of call-up maneuver, decreased with the severity of chronic venous disease in those patients measured by the clinical classification of CEAP (r = -0.64; P = 0.03). Manual lymphatic drainage increases the venous blood flow in the lower extremity with a magnitude that is independent from the specific maneuver employed or the presence of chronic venous disease. Therefore, manual lymphatic drainage may be an alternative strategy for the treatment and prevention of venous stasis complications in chronic venous disease. © The Author(s) 2013 Reprints and permissions: sagepub.co.uk/journalsPermissions.nav.

  20. Outcome of transarterial treatment of dural arteriovenous fistulas with direct or indirect cortical venous drainage.

    PubMed

    Mantilla, Daniel; Le Corre, Marine; Cagnazzo, Federico; Gascou, Gregory; Eker, Omer; Machi, Paolo; Riquelme, Carlos; Dargazanli, Cyril; Costalat, Vincent; Bonafe, Alain; Lefevre, Pierre-Henri

    2018-01-30

    Transarterial Onyx embolization is an effective treatment for patients with intracranial dural arteriovenous fistula (DAVF). A study was performed to determine whether the clinical and radiological outcomes after transarterial Onyx treatment were affected by the type of cortical venous drainage (direct vs indirect) of high-grade DAVF. Between May 2006 and December 2014, demographic data, clinical presentation, angiographic characteristics, and treatment-related outcomes were collected for 54 patients divided into two groups (intracranial DAVF with direct and indirect cortical venous drainage). Continuous variables were compared with the two-tailed t test and categorical variables with the χ 2 test. Statistical significance was set at P<0.05. Fifty-two patients (71% with direct and 29% with indirect cortical venous drainage) underwent Onyx embolization. Immediate complete occlusion after treatment was observed in about 55% of patients without between-group difference. During the long-term follow-up, complete angiographic occlusion was achieved in 83% of patients. Specifically, 15 additional patients (40%) in the direct cortical venous drainage group progressed to complete occlusion, but only one (6%) in the indirect cortical venous drainage group. Overall, the rate of complete occlusion was higher in patients with DAVF with direct cortical venous drainage (92%) than in those with DAVF with indirect cortical venous drainage (62.5%) (P=0.01). The rate of permanent treatment-related complications was 4%, mostly related to ischemic events. Overall, 80.5% of patients had a good neurological outcome (modified Rankin Scale score 0-2). Transarterial Onyx embolization of intracranial high-grade DAVF is safe and effective, particularly for lesions with direct cortical venous drainage. © Article author(s) (or their employer(s) unless otherwise stated in the text of the article) 2018. All rights reserved. No commercial use is permitted unless otherwise expressly granted.

  1. Clinical application of three-dimensional printing to the management of complex univentricular hearts with abnormal systemic or pulmonary venous drainage.

    PubMed

    McGovern, Eimear; Kelleher, Eoin; Snow, Aisling; Walsh, Kevin; Gadallah, Bassem; Kutty, Shelby; Redmond, John M; McMahon, Colin J

    2017-09-01

    In recent years, three-dimensional printing has demonstrated reliable reproducibility of several organs including hearts with complex congenital cardiac anomalies. This represents the next step in advanced image processing and can be used to plan surgical repair. In this study, we describe three children with complex univentricular hearts and abnormal systemic or pulmonary venous drainage, in whom three-dimensional printed models based on CT data assisted with preoperative planning. For two children, after group discussion and examination of the models, a decision was made not to proceed with surgery. We extend the current clinical experience with three-dimensional printed modelling and discuss the benefits of such models in the setting of managing complex surgical problems in children with univentricular circulation and abnormal systemic or pulmonary venous drainage.

  2. Confluent hepatic fibrosis in liver cirrhosis: possible relation with middle hepatic venous drainage.

    PubMed

    Ozaki, Kumi; Matsui, Osamu; Gabata, Toshifumi; Kobayashi, Satoshi; Koda, Wataru; Minami, Tetsuya

    2013-08-01

    Our aim was to retrospectively analyze the location of confluent hepatic fibrosis in relation to the portal and hepatic venous anatomy using multidetector computed tomography (CT) and to clarify the influence of the hepatic venous drainage on confluent fibrosis. The study population consisted of 879 patients diagnosed with cirrhosis: 539 men and 340 women (65.9 ± 10.6 years) and 633 with Child-Pugh class A, 161 with class B, and 85 with class C. The cause of cirrhosis was hepatitis C (n = 528) and hepatitis B (n = 122) virus infection, alcoholism (n = 114), and others (n = 115). The confluent fibrosis was diagnosed using CT images according to previous reports and statistically analyzed (p < 0.05). Thirty-five confluent fibrosis lesions in 30 patients (3.4 %) were identified. The predictive factors were alcoholic cirrhosis [odds ratio (OR), 7.25; p < 0.0001], Child-Pugh class C (OR, 6.95; p < 0.0001), and Child-Pugh class B (OR, 2.91; p < 0.0023). Confluent fibrosis was most frequently seen in the middle hepatic venous drainage area (n = 21) or at the boundary between the medial and anterior segments (n = 17), and each distribution of the location of confluent fibrosis was significantly unequal (p < 0.0001). Confluent fibrosis was most commonly located in the middle hepatic venous drainage area.

  3. MRI Evidence for Altered Venous Drainage and Intracranial Compliance in Mild Traumatic Brain Injury

    PubMed Central

    Pomschar, Andreas; Koerte, Inga; Lee, Sang; Laubender, Ruediger P.; Straube, Andreas; Heinen, Florian; Ertl-Wagner, Birgit; Alperin, Noam

    2013-01-01

    Purpose To compare venous drainage patterns and associated intracranial hydrodynamics between subjects who experienced mild traumatic brain injury (mTBI) and age- and gender-matched controls. Methods Thirty adult subjects (15 with mTBI and 15 age- and gender-matched controls) were investigated using a 3T MR scanner. Time since trauma was 0.5 to 29 years (mean 11.4 years). A 2D-time-of-flight MR-venography of the upper neck was performed to visualize the cervical venous vasculature. Cerebral venous drainage through primary and secondary channels, and intracranial compliance index and pressure were derived using cine-phase contrast imaging of the cerebral arterial inflow, venous outflow, and the craniospinal CSF flow. The intracranial compliance index is the defined as the ratio of maximal intracranial volume and pressure changes during the cardiac cycle. MR estimated ICP was then obtained through the inverse relationship between compliance and ICP. Results Compared to the controls, subjects with mTBI demonstrated a significantly smaller percentage of venous outflow through internal jugular veins (60.9±21% vs. controls: 76.8±10%; p = 0.01) compensated by an increased drainage through secondary veins (12.3±10.9% vs. 5.5±3.3%; p<0.03). Mean intracranial compliance index was significantly lower in the mTBI cohort (5.8±1.4 vs. controls 8.4±1.9; p<0.0007). Consequently, MR estimate of intracranial pressure was significantly higher in the mTBI cohort (12.5±2.9 mmHg vs. 8.8±2.0 mmHg; p<0.0007). Conclusions mTBI is associated with increased venous drainage through secondary pathways. This reflects higher outflow impedance, which may explain the finding of reduced intracranial compliance. These results suggest that hemodynamic and hydrodynamic changes following mTBI persist even in the absence of clinical symptoms and abnormal findings in conventional MR imaging. PMID:23405151

  4. Partial anomalous pulmonary venous drainage. A novel approach to repair.

    PubMed

    Hanhan, U A; Moodie, D S; Gill, C C; Sterba, R; Currie, P; Stewart, R

    1989-01-01

    Isolated partial anomalous pulmonary venous drainage with an intact atrial septum is a rare finding. The authors describe their experience with three patients (ages 9, 37, and 54 years), with partial anomalous pulmonary venous connection to the superior vena cava, right atrium, and inferior vena cava, who underwent extracardiac conduit repair of this anomaly. In all three patients, a synthetic Gortex graft was used for reconstruction of the venous pathways to the left atrium. The follow-up period ranged from 10 to 82 months (mean, 42 months). All three patients were evaluated with intravenous digital angiography, transesophageal echocardiography, or both at 10, 33, and 82 months postoperatively. Patency of the grafts with no evidence of obstruction and excellent pulmonary venous flow was shown. This surgical technique is an excellent option for correction of this anomaly, and intravenous digital subtraction angiography is a useful diagnostic tool during the postoperative period to evaluate patency of the repair.

  5. 49 CFR 570.56 - Vacuum brake assist unit and vacuum brake system.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    .... The following requirements apply to vehicles with vacuum brake assist units and vacuum brake systems. (a) Vacuum brake assist unit integrity. The vacuum brake assist unit shall demonstrate integrity as... maintained on the pedal. (1) Inspection procedure. Stop the engine and apply service brake several times to...

  6. New, Virtually Wall-less Cannulas Designed for Augmented Venous Drainage in Minimally Invasive Cardiac Surgery.

    PubMed

    von Segesser, Ludwig Karl; Berdajs, Denis; Abdel-Sayed, Saad; Tozzi, Piergiorgio; Ferrari, Enrico; Maisano, Francesco

    2016-01-01

    Inadequate venous drainage during minimally invasive cardiac surgery becomes most evident when the blood trapped in the pulmonary circulation floods the surgical field. The present study was designed to assess the in vivo performance of new, thinner, virtually wall-less, venous cannulas designed for augmented venous drainage in comparison to traditional thin-wall cannulas. Remote cannulation was realized in 5 bovine experiments (74.0 ± 2.4 kg) with percutaneous venous access over the wire, serial dilation up to 18 F and insertion of either traditional 19 F thin wall, wire-wound cannulas, or through the same access channel, new, thinner, virtually wall-less, braided cannulas designed for augmented venous drainage. A standard minimal extracorporeal circuit set with a centrifugal pump and a hollow fiber membrane oxygenator, but no in-line reservoir was used. One hundred fifty pairs of pump-flow and required pump inlet pressure values were recorded with calibrated pressure transducers and a flowmeter calibrated by a volumetric tank and timer at increasing pump speed from 1500 RPM to 3500 RPM (500-RPM increments). Pump flow accounted for 1.73 ± 0.85 l/min for wall-less versus 1.17 ± 0.45 l/min for thin wall at 1500 RPM, 3.91 ± 0.86 versus 3.23 ± 0.66 at 2500 RPM, 5.82 ± 1.05 versus 4.96 ± 0.81 at 3500 RPM. Pump inlet pressure accounted for 9.6 ± 9.7 mm Hg versus 4.2 ± 18.8 mm Hg for 1500 RPM, -42.4 ± 26.7 versus -123 ± 51.1 at 2500 RPM, and -126.7 ± 55.3 versus -313 ± 116.7 for 3500 RPM. At the well-accepted pump inlet pressure of -80 mm Hg, the new, thinner, virtually wall-less, braided cannulas provide unmatched venous drainage in vivo. Early clinical analyses have confirmed these findings.

  7. Improved vacuum sealing drainage in the treatment of gas gangrene: a case report

    PubMed Central

    Liu, Zhaofa; Zhao, Dewei; Wang, Benjie

    2015-01-01

    In this case, improved vacuum sealing drainage was used for gas gangrene treatment, which is different from traditional therapies of gas gangrene and this is the first report of using improved vacuum sealing drainage to treat gas gangrene. The patient was a 12-year-old Asian Male who was presented to the Emergency Department with a one-day history of left femoral progressing swelling, paining and fevering. Four days ago, rusty iron bars were plugged into the muscle of the left femoral when he played. Then he was taken to the local clinic and injected with tetanus antitoxin. A diagnosis of gas gangrene was made and modified vacuum sealing drainage device was used after thorough debridement. After two weeks’ treatment, left femoral was kept and gas gangrene was cured successfully. PMID:26770624

  8. Improved vacuum sealing drainage in the treatment of gas gangrene: a case report.

    PubMed

    Liu, Zhaofa; Zhao, Dewei; Wang, Benjie

    2015-01-01

    In this case, improved vacuum sealing drainage was used for gas gangrene treatment, which is different from traditional therapies of gas gangrene and this is the first report of using improved vacuum sealing drainage to treat gas gangrene. The patient was a 12-year-old Asian Male who was presented to the Emergency Department with a one-day history of left femoral progressing swelling, paining and fevering. Four days ago, rusty iron bars were plugged into the muscle of the left femoral when he played. Then he was taken to the local clinic and injected with tetanus antitoxin. A diagnosis of gas gangrene was made and modified vacuum sealing drainage device was used after thorough debridement. After two weeks' treatment, left femoral was kept and gas gangrene was cured successfully.

  9. Performance increase in venous drainage for mini-invasive heart surgery: superiority of self-expanding cannulas.

    PubMed

    Belkoniene, Mhedi; Abdel-Sayed, Saad; Favre, Julien; von Segesser, Ludwig-Karl

    2014-01-01

    Originally, the Smartcanula principle (collapsed insertion and expansion in situ) was developed for venous drainage by gravity. However, in minimally invasive surgery, augmentation with either constrained force vortex pumps or vacuum is often used. The current study was set up to assess whether smaller diameters of self-expanding venous cannulas are sufficient in conjunction with venous drainage augmentation resulting in smaller access orifices. To evaluate cannulas intended for cardiopulmonary bypass, an in vitro circuit was set up with silicone tubing between the test cannula encased in a lower reservoir, the centrifugal pump, and after an upper reservoir. Afterload was set arbitrarily at 60 mm Hg using a centrifugal pump. The pressure value was measured using Millar pressure transducers. Flow rate (Q) was measured using an ultrasonic flow meter calibrated with volume tank and timer. Revolutions per minute of the centrifugal pump were calibrated with a stroboscope. Data display and data recording were controlled using a Lab View application. Self-expanding (24F Smartcanula) and control (25F Biomedicus) cannulas were used. Sixty measurements were recorded. At pump speed of 1500, 1570, 2000, 2500, and 3000 rpm, the Q values were 3.6, 5.2, 6.6, 9.3, and 11.8 L/min for the 24F self-expanding cannula and 3, 4.3, 5.4, 7.5, and 9.3 L/min for the control cannula. The pressure values were 3.6, -5.4, -15.9, -45.3, and 80.6 mm Hg. Biomedicus 25F showed Q values from 16% to 19% less as compared with 24F Smartcanula. The pressure values were 6, 7, 4, 2, and 2 times more as compared with 24F Smartcanula. Our experimental evaluation demonstrated the superior performance of the Smartcanula with its self-expanding design in comparison with the reference commercially available standard cannulas. The Smartcanula with its small diameter is particularly welcome for minimally invasive surgery.

  10. Enhancement of venous drainage with vein stripper for reversed pedicled neurocutaneous flaps.

    PubMed

    Sonmez, Erhan; Silistireli, Özlem Karataş; Karaaslan, Önder; Kamburoğlu, Haldun Onuralp; Safak, Tunc

    2013-05-01

    The flaps based on the vascular axis of superficial sensitive cutaneous nerves had gained increased popularity in reconstructive surgery because of such major advantages as preservation of major extremity arteries and avoidance of microsurgical procedures. However, postoperative venous congestion resulting in partial or total necrosis is still a common problem for these flaps. The aim of the current study is to introduce a new method for reducing the postoperative venous congestion of neural island flap with the results of reconstruction of the soft tissue defects of foot and ankle. This method was used to treat 19 patients with various chronic soft tissue defects of the foot and ankle between 2011 and 2012. We observed that the novel method presented in this report enables effective venous drainage, solving the postoperative venous congestion problem of these flaps. Thieme Medical Publishers 333 Seventh Avenue, New York, NY 10001, USA.

  11. [Surgical treatment of partial anomalous pulmonary venous drainage].

    PubMed

    Cabrera, A; Idígoras, G; Sarrionandía, M J; Martínez, P; Rumoroso, J R; Alcíbar, J

    1996-02-01

    We studied all patients operated for partial anomalous pulmonary venous drainage and half-time follow-up. Twenty-eight patients with a mean age of 5 +/- 5 years (5 patients were less than 1 year old). There were sixteen male and twelve female patients. Thirteen patients were symptomatic (47%). The drainage was to the superior vena cava in thirteen cases, to the inferior vena cava in eight cases, to the right atrium in five cases, mixed (to the superior vena cava and to the inferior vena cava) in one case and to the innominate vein in one patient. The diagnosis was made through echocardiography and catheterization in 25 patients, whereas nuclear magnetic resonance was performed in the last five patients. All cases were corrected through medium thoracotomy, except for the single case in which the drainage was to the innominate vein). In 27 patients, the pulmonary veins were guided to the left atrium through an enlarged present atrial septal defect or through a created atrial septal defect. In one case a direct connection was performed from the veins to the left atrium. After the surgical correction, all patients underwent a color-coded Doppler echocardiography study and a nuclear magnetic resonance study was performed in five patients. Twenty-seven patients survived after surgical correction. The patient with a mixed drainage developed an obstruction of the superior vena cava, the pressure gradient was 9 mmHg. He required a second surgical procedure followed with angioplasty on two occasions during a six month period. Two patients showed an ectopic atrial rhythm at some late time. The patient who died was one month old and had an associated pulmonary parenchymal sequestration. Partial anomalous venous connection is a congenital heart disease which has an easy surgical correction. Complications may arise after the surgical correction, among them obstruction of the superior vena cava and arrythmias are most frequently found. Obstruction is present when 50% of the caval

  12. Thoracoscopic Surgery for Partial Anomalous Pulmonary Venous Connection with Dual Drainage.

    PubMed

    Fuchigami, Tai; Gabe, Atsushi; Takahashi, Kazuhiro; Nishioka, Masahiko; Akashige, Toru; Nagata, Nobuhiro

    2015-10-01

    We report our technique for thoracoscopic surgery for a 15-year-old female (body weight, 59 kg) diagnosed with partial anomalous pulmonary venous connection with dual drainage. A large anomalous right lower pulmonary vein (RLPV) was drained into the inferior vena cava and left atrium, along with thoracoscopic ligation and clipping of RLPV and some anomalous hepatic veins. © 2015 Wiley Periodicals, Inc.

  13. A high-vacuum wound drainage system reduces pain and length of treatment for pediatric soft tissue abscesses.

    PubMed

    Yang, Chao; Wang, Shan; Li, Chang-Chun; Kong, Xiang-Ru; Zhao, Zhenzhen; Deng, Xiao-Bin; Peng, Liang; Zhang, Jun

    2017-02-01

    Open incision and drainage (I&D) and wound packing is accepted as the standard treatment for soft tissue abscesses. However, conventional I&D has a number of problems in practice which prompt us to improve the I&D methods that would minimize the pain associated with packing during dressing changes. In order to compare the pain associated with dressing changes in the conventional I&D group to the vacuum system group and the treatment time of both groups, we performed a randomized trial in pediatric patients between 0 and 18 years of age who are undergoing abscess drainage in the operating room from April 2011 to April 2015. Patients treated with open I&D (n = 648) were compared to those treated with placement of high-vacuum wound drainage system (n = 776) through the abscess cavities. Both groups received equivalent antibiotic treatment, and all patients were followed up in the outpatient clinics until the infection has been resolved. The mean FACES scale pain scores were significantly higher in the open I&D group than in the vacuum system group. The vacuum system group had a shorter length of stay and less need for community doctor or outpatient dressing changes than the open I&D group (p < 0.001). No recurrent abscesses were observed in the vacuum system group, and 10 patients in the open I&D group required another drainage at the exact same location. High-vacuum wound drainage system was an efficient and safe alternative to the traditional I&D for community-acquired soft tissue abscesses with few complications in short term. What is Known: • Open incision and drainage (I&D) followed by irrigation and wound packing is the standard treatment for soft tissue abscesses. • The painful daily packing may cause emotional trauma to the child and lead to an unwelcoming challenge to the caretakers and health care providers. What is New: • We modified the method of I&D by adding primary suturing of the wound and placement of a high-vacuum wound drainage system

  14. 21 CFR 864.9125 - Vacuum-assisted blood collection system.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Vacuum-assisted blood collection system. 864.9125... Blood and Blood Products § 864.9125 Vacuum-assisted blood collection system. (a) Identification. A vacuum-assisted blood collection system is a device intended for medical purposes that uses a vacuum to...

  15. 21 CFR 864.9125 - Vacuum-assisted blood collection system.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... 21 Food and Drugs 8 2013-04-01 2013-04-01 false Vacuum-assisted blood collection system. 864.9125... Blood and Blood Products § 864.9125 Vacuum-assisted blood collection system. (a) Identification. A vacuum-assisted blood collection system is a device intended for medical purposes that uses a vacuum to...

  16. 21 CFR 864.9125 - Vacuum-assisted blood collection system.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... 21 Food and Drugs 8 2014-04-01 2014-04-01 false Vacuum-assisted blood collection system. 864.9125... Blood and Blood Products § 864.9125 Vacuum-assisted blood collection system. (a) Identification. A vacuum-assisted blood collection system is a device intended for medical purposes that uses a vacuum to...

  17. 21 CFR 864.9125 - Vacuum-assisted blood collection system.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... 21 Food and Drugs 8 2012-04-01 2012-04-01 false Vacuum-assisted blood collection system. 864.9125... Blood and Blood Products § 864.9125 Vacuum-assisted blood collection system. (a) Identification. A vacuum-assisted blood collection system is a device intended for medical purposes that uses a vacuum to...

  18. 21 CFR 864.9125 - Vacuum-assisted blood collection system.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Vacuum-assisted blood collection system. 864.9125... Blood and Blood Products § 864.9125 Vacuum-assisted blood collection system. (a) Identification. A vacuum-assisted blood collection system is a device intended for medical purposes that uses a vacuum to...

  19. [Tentorial Dural Arteriovenous Fistula Successfully Treated with Transvenous Embolization Using a Double Catheterization Technique through Venous Drainage:A Case Report].

    PubMed

    Yamakawa, Akira; Fujita, Atsushi; Tanaka, Hirotomo; Ikeda, Mitsuru; Morikawa, Masashi; Kohmura, Eiji

    2017-07-01

    Tentorial dural arteriovenous fistulas(dAVFs)are a rare clinical entity accounting for less than 10% of all intracranial dAVFs. Because these lesions are characterized by high hemorrhagic risk, aggressive treatment should be considered. Although the number of reported cases treated with endovascular transarterial embolization(TAE)using glue has been increasing, little is known about the transvenous approach. Here, we report the case of a patient with a tentorial dAVF who was successfully treated with transvenous embolization(TVE)through venous drainage using a double catheterization technique. A 68-year-old male patient who had a history of left putaminal hemorrhage treated with a craniotomy was diagnosed with a tentorial dAVF on a magnetic resonance angiogram. Because the patient refused another craniotomy for surgical interruption of the dAVF, an endovascular approach was considered. We first attempted to perform TAE with glue, but catheterization into the tortuous meningohypophyseal trunk failed. We then performed a TVE of the venous drainage near the shunt with detachable coils and achieved complete obliteration of the fistula. During coil embolization of the venous drainage, insertion of small coils near the shunt was supported by another anchor coil that was delivered using a double catheterization technique. The method of TVE through venous drainage using a double catheterization technique, which involved placing coils in the fragile drainage vein, was safe and effective in a case of tentorial dAVF. This technique should be considered as another option for the management of complex tentorial dAVFs.

  20. Suprascarpal fat pad thickness may predict venous drainage patterns in abdominal wall flaps.

    PubMed

    Bast, John; Pitcher, Austin A; Small, Kevin; Otterburn, David M

    2016-02-01

    Abdominal wall flaps are routinely used in reconstructive procedures. In some patients inadequate venous drainage from the deep vein may cause fat necrosis or flap failure. Occasionally the superficial inferior epigastric vessels (SIEV) are of sufficient size to allow for microvascular revascularization. This study looked at the ratio of the sub- and suprascarpal fat layers, the number of deep system perforators, and SIEV diameter to determine any correlation of the fat topography and SIEV. 50 abdominal/pelvic CT angiograms (100 hemiabdomens) were examined in women aged 34-70 years for number of perforators, SIEV diameter, and fat pad thickness above and below Scarpa's fascia. Data was analyzed using multivariate model. The average suprascarpal and subscarpal layers were 18.6 ± 11.5 mm and 6.2 ± 7.2 mm thick, respectively. The average SIEV diameter was 2.06 ± 0.81 mm and the average number of perforators was 2.09 ± 1.03 per hemiabdomen. Hemiabdomens with suprascarpal thickness>23 mm had greater SIEV diameter [2.69 mm vs. 1.8 mm (P < 0.0001)] The fat layer thickness did not correlate with the number of perforators. Neither subscarpal fat thickness nor suprascarpal-to-subscarpal fat layer thickness correlated significantly with SIEV caliber or number of perforators in multivariate model. Suprascarpal fat pad thicker than 23 mm had larger SIEVs irrespective of the number of deep system perforators. This may indicate a cohort of patients at risk of venous congestion from poor venous drainage if only the deep system is revascularized. We recommend harvesting the SIEV in patients with suprascarpal fat pad >23 mm to aid in superficial drainage. © 2015 Wiley Periodicals, Inc.

  1. Evaluation of venous distension device: potential aid for intravenous cannulation.

    PubMed

    Hedges, J R; Weinshenker, E; Dirksing, R

    1986-05-01

    A device designed to augment venous filling by applying a vacuum to the upper extremity during tourniquet application was evaluated. Ten healthy adult male volunteers with clinical normovolemia were studied for changes in forearm volume and dorsal hand vein turgor during use of an elastic tubing tourniquet, a blood pressure cuff tourniquet, and a vacuum-assisted cuff tourniquet. Use of the device for 30 seconds was not associated with petechia formation and resulted in a significant increase in venous turgor, as measured by an ophthalmologic tonometer, in comparison to the other tourniquet techniques (P less than .005). Use for 60 seconds was associated with mild to moderate subjective discomfort in all volunteers and petechiae in all nine white volunteers. All petechiae resolved in three days. Venous engorgement as reflected by volume displacement was significantly greater for the vacuum device and blood pressure cuff tourniquet combination than other techniques at 30 and 60 seconds of tourniquet application (P less than .005). Brief application of a vacuum to the arm during tourniquet use increases venous turgor and engorgement in normovolemic volunteers.

  2. Fast MRI-guided vacuum-assisted breast biopsy: initial experience.

    PubMed

    Liberman, Laura; Morris, Elizabeth A; Dershaw, D David; Thornton, Cynthia M; Van Zee, Kimberly J; Tan, Lee K

    2003-11-01

    The purpose of this study was to evaluate a new method for performing MRI-guided vacuum-assisted breast biopsy in a study of lesions that had subsequent surgical excision. SUBJECTS AND METHODS. Twenty women scheduled for MRI-guided needle localization and surgical biopsy were prospectively entered in the study. MRI-guided biopsy was performed with a vacuum-assisted probe, followed by placement of a localizing clip, and then needle localization for surgical excision. Vacuum-assisted biopsy and surgical histology were correlated. Vacuum-assisted biopsy was successfully performed in 19 (95%) of the 20 women. The median size of 27 MRI-detected lesions that had biopsy was 1.0 cm (range, 0.4-6.4 cm). Cancer was present in eight (30%) of 27 lesions and in six (32%) of 19 women; among these eight cancers, five were infiltrating and three were ductal carcinoma in situ (DCIS). Among these 27 lesions, histology was benign at vacuum-assisted biopsy and at surgery in 19 (70%), cancer at vacuum-assisted biopsy in six (22%), atypical ductal hyperplasia at vacuum-assisted biopsy and DCIS at surgery in one (4%), and benign at vacuum-assisted biopsy with surgery showing microscopic DCIS that was occult at MRI in one (4%). The median time to perform vacuum-assisted biopsy of a single lesion was 35 min (mean, 35 min; range, 24-48 min). Placement of a localizing clip, attempted in 26 lesions, was successful in 25 (96%) of 26, and the clip was retrieved on specimen radiography in 22 (96%) of 23. One complication occurred: a hematoma that resolved with compression. MRI-guided vacuum-assisted biopsy is a fast, safe, and accurate alternative to surgical biopsy for breast lesions detected on MRI.

  3. Agenesis of the venous duct: two cases of extrahepatic drainage of the umbilical vein and extrahepatic portosystemic shunt with a review of the literature.

    PubMed

    Loomba, Rohit S; Frommelt, Michele; Moe, David; Shillingford, Amanda J

    2015-02-01

    Agenesis of the venous duct is a rare congenital anomaly resulting in abnormal drainage of the umbilical vein into the foetal venous circulation. The clinical presentation and prognosis is variable, and may depend on the specific drainage pathways of the umbilical vein. We present two foetuses with agenesis of the venous duct, both associated with a postnatal portosystemic shunt, but with markedly different postnatal clinical courses. We also review all previously reported cases to better characterise this foetal disorder and the prognosis.

  4. [POSSIBILITIES OF VACUUM THERAPY APPLICATION IN DISORDERS OF VENOUS OUTFLOW IN ISLET GRAFTS].

    PubMed

    Badyul, P O; Samoylenko, G E; Nor, N M; Slesarenko, K S

    2015-07-01

    The experience of "distressed" (problematic) flaps application in 33 patients with soft tissue defects over 2010-2014 years were analysed. It was proposed to use the local negative pressure for the prevention and treatment of complications associated with venous insufficiency or trombosis in using of plastics with vascularised complexes of tissues. Vacuum-therapy was conducted with the help of negative pressure apparatus "AGATE-Dnepr" (Ukraine) by attaching silver-containing polyurethane sponge on the operating zone, covering the flap with the surrounding skin netting band "Grassolind". The recommended standard of negative pressure of 75-125 mm Hg, both in impulse and in continuous mode was used. The high efficiency of vacuum-therapy for survival of grafts has been demonstrated. Thus, it might be considered as an effective element of prevention and treatment of complications associated with venous insufficiency or trombosis using of vascularised tissue complex plastics of defects.

  5. The evolution of anterior sector venous drainage in right lobe living donor liver transplantation: does one technique fit all?

    PubMed Central

    Tokat, Yaman

    2016-01-01

    In living donor liver transplantation (LDLT), an adequate hepatic venous outflow constitutes one of the basic principles of a technically successful procedure. The issue of whether the anterior sector (AS) of the right lobe (RL) graft should or should not be routinely drained has been controversial. The aim of this 10-year, single-center, retrospective cohort study was to review the evolution of our hepatic venous outflow reconstruction technique in RL grafts and evaluate the impact of routine AS drainage strategy on the outcome. The study group consisted of 582 primary RL LDLT performed between July 2004 and December 2014. The cases were divided into 3 consecutive periods with different AS venous outflow reconstruction techniques, which included middle hepatic vein (MHV) drainage in Era 1 (n=119), a more selective AS drainage with cryopreserved homologous grafts in Era 2 (n=391), and routine segment 5 and/or 8 oriented AS drainage with synthetic grafts in Era 3 (n=72). Intraoperative portal flow measurement with routine splenic artery ligation (SAL) technique (in RL grafts with a portal flow of ≥ 250 mL/min/100 g liver tissue) was added later in Era 3. These 3 groups were compared in terms of recipient and donor demographics, surgical characteristics and short-term outcome. The rate of AS venous drainage varied from 58.8% in Era 1 and 35.0% in Era 2 to 73.6% in Era 3 (P<0.001). Perioperative mortality rate of recipients significantly decreased over the years (15.1% in Era 1 and 8.7% in Era 2 vs. 2.8% in Era 3, P=0.01). After the addition of SAL technique in the 45 cases, there was only 1 graft loss and no perioperative mortality. One-year recipient survival rate was also significantly higher in Era 3 (79.6% in Era 1 and 86.1% in Era 2 vs. 92.1% in Era 3, P=0.002). Routine AS drainage via segment 5 and/or 8 veins using synthetic grafts is a technique to fit all RL grafts in LDLT. Addition of SAL effectively prevents early graft dysfunction and significantly

  6. Half versus full vacuum suction drainage after modified radical mastectomy for breast cancer- a prospective randomized clinical trial[ISRCTN24484328

    PubMed Central

    Chintamani; Singhal, Vinay; Singh, JP; Bansal, Anju; Saxena, Sunita

    2005-01-01

    Background Suction drains are routinely used after modified radical mastectomy and are an important factor contributing to increased hospital stay as the patients are often discharged only after their removal. Amongst various factors that influence the amount of postoperative drainage, the negative suction pressure applied to the drain has been reported to be of great significance. While a high negative suction pressure is expected to drain the collection and reduce the dead space promptly, it may also prevent the leaking lymphatics from closing and lead to increased drainage from the wound. Against this background a prospective randomized clinical study was conducted to compare the amount and duration of drainage between a half negative suction and full vacuum suction drainage in patients following modified radical mastectomy. The associated postoperative morbidity was also compared between the two groups. Methods 85 FNAC (fine needle aspiration cytology) proven cases of locally advanced breast cancer were randomized. (Using randomly ordered sealed envelops, which were opened immediately before the closure of the wound) in to 50 patients with full vacuum suction (pressure = 700 g/m2) and 35 cases in to half vacuum suction drainage (pressure = 350 g/m2) groups. The two groups were comparable in respect of age, weight, and technique of operation and extent of axillary dissection. Surgery was performed by the same surgical team comprising of five surgeons (two senior and three resident surgeons) using a standardized technique with electrocautery. External compression dressing was provided over the axilla for first 48 hrs and following that patients were encouraged to do active and passive shoulder exercises. The outcomes measured were postoperative morbidity and the length of hospital stay. Statistical methods used: Descriptive studies were performed with SPSS version 10 and group characteristics were compared using student t-test. Results Half vacuum suction drains

  7. [Vacuum sealing drainage for infection wound in earthquake].

    PubMed

    Liao, Dengbin; Ning, Ning; Liu, Xiaoyan; Gan, Chunlan

    2009-10-01

    To investigate the effect of vacuum sealing drainage (VSD) technology on prevention and treatment of infection wound and to repair the infectious fracture wound in earthquake. Twenty-two patients with limb fractures and open infection wound received VSD from May 12, 2008 to June 19, 2008 in West China Hospital of Sichuan University. Before the VSD, we debrided all wounds and gave effective systemic antibiotics. A -18 ~ -14 kPa pressure was exerted to the wound, and the VSD was used for 8-10 days. We took a germiculture regularly. The capacity, color, and nature of negative pressure drainage, the regression of limb swelling, and systemic inflammatory responses were observed. There was no active bleeding wound or transparent film off in all patients. Three patients had drainage clogging, and were kept flowing freely using the sterile saline pipe to remove the blockage of necrotic tissues. During the VSD, granulation tissues grew well in the 13 patients with bone exposure of the wounded. Two patients whose symptom of inflammatory was not obviously eased had another debridement to completely remove the necrosis, and the symptom was relieved. After 3-5 days of VSD, swelling and fever in the other 20 patients significantly subsided. VSD can alleviate the wound inflammation, facilitate the growth of the fresh granulation tissue from the surrounding to the center, and reduce the flap transfer area for the Stage II coverage of the exposed bone.

  8. [Vacuum sealing drainage combined with free skin graft in repairing cutaneous deficiency of traumatic shank amputation stump].

    PubMed

    Zhao, Xiao-fei; Li, Chun-you; Jin, Guo-qiang; Ming, Xiao-feng; Wang, Guo-jie

    2014-12-01

    To observe clinical efficacy in treating cutaneous deficiency of traumatic shank amputation stump with full-thickness skin graft combined with vacuum sealing drainage. From September 2009 to December 2012, 15 patients with cutaneous deficiency of traumatic shank amputation stump were treated with full-thickness skin graft combined with vacuum sealing drainage. Among patients, there were 11 males and 4 females with an average age of 41.5 (ranged from 25 to 62) years old. Ten cases were caused by traffic accident and 5 cases were caused by heavy object, 9 cases on left and 6 cases on right. Six patients with smashed wound were treated with debridement and amputation, combined with vacuum aspiration in-emergency; 9 patients caused by infection and necrosis were treated with debridement and amputation, combined with vacuum aspiration, and full-thickness skin graft were performed at stage II. The skin defect area of residual limbs ranged from 40 cm x 20 cm to 25 cm x 15 cm. All patients were followed up from 3 months to 1 year. Full-thickness skin graft of residual limbs were survived,and obtained satisfactory walking function with prosthetic. Residual skin increased thicken, wearproof without rupture and pain. Full-thickness skin graft combined with vacuum sealing drainage in treating cutaneous deficiency of traumatic shank amputation stump could reserve the length of residual limbs, increase survival rate of skin graft with less scar of survival skin, get good wearability and it is conducive to prosthetic wear. It is a simple and easy treatment method.

  9. Assistive technology for ultrasound-guided central venous catheter placement.

    PubMed

    Ikhsan, Mohammad; Tan, Kok Kiong; Putra, Andi Sudjana

    2018-01-01

    This study evaluated the existing technology used to improve the safety and ease of ultrasound-guided central venous catheterization. Electronic database searches were conducted in Scopus, IEEE, Google Patents, and relevant conference databases (SPIE, MICCAI, and IEEE conferences) for related articles on assistive technology for ultrasound-guided central venous catheterization. A total of 89 articles were examined and pointed to several fields that are currently the focus of improvements to ultrasound-guided procedures. These include improving needle visualization, needle guides and localization technology, image processing algorithms to enhance and segment important features within the ultrasound image, robotic assistance using probe-mounted manipulators, and improving procedure ergonomics through in situ projections of important information. Probe-mounted robotic manipulators provide a promising avenue for assistive technology developed for freehand ultrasound-guided percutaneous procedures. However, there is currently a lack of clinical trials to validate the effectiveness of these devices.

  10. Window-assisted nanosphere lithography for vacuum micro-nano-electronics

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Li, Nannan; Institute of Electronic Engineering, Chinese Academy of Engineering Physics, Mianyang, 621900; Pang, Shucai

    2015-04-15

    Development of vacuum micro-nano-electronics is quite important for combining the advantages of vacuum tubes and solid-state devices but limited by the prevailing fabricating techniques which are expensive, time consuming and low-throughput. In this work, window-assisted nanosphere lithography (NSL) technique was proposed and enabled the low-cost and high-efficiency fabrication of nanostructures for vacuum micro-nano-electronic devices, thus allowing potential applications in many areas. As a demonstration, we fabricated high-density field emitter arrays which can be used as cold cathodes in vacuum micro-nano-electronic devices by using the window-assisted NSL technique. The details of the fabricating process have been investigated. This work provided amore » new and feasible idea for fabricating nanostructure arrays for vacuum micro-nano-electronic devices, which would spawn the development of vacuum micro-nano-electronics.« less

  11. Ectopic drainage from the inferior vena cava to the left atrium together with a partial anomalous pulmonary venous connection.

    PubMed

    Wu, Yuan; Xu, Shuangyue; Guo, Hongwei; Yan, Guoliang; Qi, Zhongquan; Shan, Zhonggui

    2014-07-01

    We report a case of a 44-year-old male patient with ectopic drainage from the inferior vena cava to the left atrium accompanied by partial anomalous pulmonary venous drainage. After the patient was hospitalized, his diagnosis was confirmed by Doppler echocardiography and angiography. A pericardial patch was used to divert the blood to the atrium. The surgical procedure was successful, and the patient began a rehabilitation program 8 days later. This type of ectopic drainage pattern is an unusual and infrequent clinical finding. The definitive diagnosis should be made by Doppler ultrasound combined with angiography. Copyright © 2014 Elsevier Inc. All rights reserved.

  12. Idiopathic sudden sensorineural hearing loss and ménière syndrome: The role of cerebral venous drainage.

    PubMed

    Ciccone, M M; Scicchitano, P; Gesualdo, M; Cortese, F; Zito, A; Manca, F; Boninfante, B; Recchia, P; Leogrande, D; Viola, D; Damiani, M; Gambacorta, V; Piccolo, A; De Ceglie, V; Quaranta, N

    2018-02-01

    To evaluate the influence of cerebral venous drainage on the pathogenesis of idiopathic sudden sensorineural hearing loss (ISSHL) and Ménière syndrome (MD). Observational, prospective, cohort study. ENT and Cardiology Departments (University of Bari, Policlinico Hospital, Bari, Italy). We enrolled 59 consecutive patients (32 males, mean age 53.05 + 15.37 years): 40 ISSHL and 19 MD. All patients underwent physical examination, biochemical evaluation (glycemic and lipid profile, viral serology, C reactive protein, etc), audiometric (tonal, vocal, vestibular evoked myogenic potentials and auditory brainstem response test) and impedentiometric examination. The pure tone average (PTA) was calculated for the following frequencies: 250, 500, 1000, 2000, 3000, 4000, 8000. An echo-color Doppler evaluation of the venous cerebral veins, internal jugular (IJV) and vertebral veins (VV) at supine and 90° position was performed. No morphological alterations were found both in patients and controls. There were no signs of stenosis, blocked flow, membranes, etc. We found lower minimum, mean and maximum velocities in distal IJVs (P = .019; P = .013; P = .022; respectively) and left VVs (P = .027; P = .008; P = .001; respectively) in supine (0°) position in both MD and ISSHL patients as compared to controls. The same was for orthostatic position (90°). We found negative correlations between the velocities in extracranial veins and PTA values: therefore, the worst the audiometric performance of the subjects, the lower the velocities in the venous cerebral drainage. Idiopathic sudden sensorineural hearing loss and Ménière syndrome patients showed altered venous flow in IJVs and VVs as compared to controls, independently from posture. This different behavior of venous tone control can influence the ear performance and may have a role in the pathogenesis of both diseases. © 2017 John Wiley & Sons Ltd.

  13. Management of traumatic hemothorax by closed thoracic drainage using a central venous catheter

    PubMed Central

    Yi, Jian-hua; Liu, Hua-bo; Zhang, Mao; Wu, Jun-song; Yang, Jian-xin; Chen, Jin-ming; Xu, Shan-xiang; Wang, Jian-an

    2012-01-01

    Objective: To evaluate the efficacy and safety of the treatment of traumatic hemothorax by closed pleural drainage using a central venous catheter (CVC), compared with using a conventional chest tube. Methods: A prospective controlled study with the Ethics Committee approval was undertaken. A total of 407 patients with traumatic hemothorax were involved and they were randomly assigned to undergo closed pleural drainage with CVCs (n=214) or conventional chest tubes (n=193). The Seldinger technique was used for drainage by CVC, and the conventional technique for drainage by chest tube. If the residual volume of the hemothorax was less than 200 ml after the daily volume of drainage decreased to below 100 ml for two consecutive days, the treatment was considered successful. The correlative data of efficacy and safety between the two groups were analyzed using t or chi-squared tests with SPSS 13.0. A P value of less than 0.05 was taken as indicating statistical significance. Results: Compared with the chest tube group, the operation time, fraction of analgesic treatment, time of surgical wound healing, and infection rate of surgical wounds were significantly decreased (P<0.05) in the CVC group. There were no significant differences between the two groups in the success rate of treatment and the incidence of serious complications (P>0.05), or in the mean catheter/tube indwelling time and mean medical costs of patients treated successfully (P>0.05). Conclusions: Management of medium or large traumatic hemothoraxes by closed thoracic drainage using CVC is minimally invasive and as effective as using a conventional large-bore chest tube. Its complications can be prevented and it has the potential to replace the large-bore chest tube. PMID:22205619

  14. Gaseous microemboli in a pediatric bypass circuit with an unprimed venous line: an in vitro study.

    PubMed

    Hudacko, Andrea; Sievert, Alicia; Sistino, Joseph

    2009-09-01

    Miniaturizing cardiopulmonary bypass (CPB) circuits to reduce hemodilution and allogenic blood product administration is common in cardiac surgery. One major concern associated with smaller CPB circuits is a possible increase in gaseous microemboli (GME) sent to the cerebral vasculature, which is exacerbated by vacuum-assisted venous drainage (VAVD). The use of VAVD has increased with smaller venous line diameter and venous cannulae. This study examines the effects of CPB initiation with an unprimed venous line and VAVD in a pediatric circuit. A CPB circuit was set up with reservoir, oxygenator, and arterial filter with a bag reservoir to simulate the patient. All trials were done in vitro, and GME were measured using the EDAC Quantifier by Luna Innovations. EDAC sensors were placed proximal and distal to the oxygenator and distal to the arterial filter. Group 1 was the control group with no VAVD and a primed venous line. Groups 2, 3, and 4 used an unprimed venous line and VAVD of -40, -20, and -10 mmHg, respectively. Total microemboli counts and total embolic load in micrometers were measured at each sensor. Groups 2 (12,379.00 +/- 3180.37) and 3 (8296.67 +/- 2818.76) had significantly more microemboli than group 1 (923.33 +/- 796.08, p < .05) at the pre-oxygenator sensor. Group 2 (57.33 +/- 25.01, p < .05) had significantly more microemboli than group 1 (5.33 +/- 3.21) at the post-oxygenator sensor. No other findings were statistically significant. The results suggest that, if an oxygenator and arterial filter with sufficient air handling capabilities are used, this method to reduce prime volume may not increase GME in the arterial line distal to the arterial filter.

  15. Venous drainage of the face.

    PubMed

    Onishi, S; Imanishi, N; Yoshimura, Y; Inoue, Y; Sakamoto, Y; Chang, H; Okumoto, T

    2017-04-01

    The venous anatomy of the face was examined in 12 fresh cadavers. Venograms and arteriovenograms were obtained after the injection of contrast medium. In 8 of the 12 cadavers, a large loop was formed by the facial vein, the supratrochlear vein, and the superficial temporal vein, which became the main trunk vein of the face. In 4 of the 12 cadavers, the superior lateral limb of the loop vein was less well developed. The loop vein generally did not accompany the arteries of the face. Cutaneous branches of the loop vein formed a polygonal venous network in the skin, while communicating branches ran toward deep veins. These findings suggest that blood from the dermis of the face is collected by the polygonal venous network and enters the loop vein through the cutaneous branches, after which blood flows away from the face through the superficial temporal vein, the facial vein, and the communicating branches and enters the deep veins. Copyright © 2016 British Association of Plastic, Reconstructive and Aesthetic Surgeons. Published by Elsevier Ltd. All rights reserved.

  16. Management of hidradenitis suppurativa wounds with an internal vacuum-assisted closure device.

    PubMed

    Chen, Y Erin; Gerstle, Theodore; Verma, Kapil; Treiser, Matthew D; Kimball, Alexandra B; Orgill, Dennis P

    2014-03-01

    Hidradenitis suppurativa is a chronic, debilitating disease that is difficult to treat. Once medical management fails, wide local excision offers the best chance for cure. However, the resultant wound often proves too large or contaminated for immediate closure. The authors performed a retrospective chart review of hidradenitis cases managed surgically between 2005 and 2010. Data collected included patient characteristics, management method, and outcomes. Approximately half of the patients received internal vacuum-assisted closure therapy using the vacuum-assisted closure system and delayed closure and half of the patients received immediate primary closure at the time of their excision. Delayed closure consisted of closing the majority of the wound in a linear fashion following internal vacuum-assisted closure while accepting healing by means of secondary intention for small wound areas. Patients managed with internal vacuum-assisted closure had wounds on average four times larger in area than patients managed without internal vacuum-assisted closure. In both groups, all wounds were eventually closed primarily. Healing times averaged 2.2 months with internal vacuum-assisted closure and 2.7 months without. At an average follow-up time of 2.3 months, all patients with internal vacuum-assisted closure had no recurrence of their local disease. Severe hidradenitis presents a treatment challenge, as surgical excisions are often complicated by difficult closures and unsatisfactory recurrence rates. This study demonstrates that wide local excision with reasonable outcomes can be achieved using accelerated delayed primary closure. This method uses internal vacuum-assisted closure as a bridge between excision and delayed primary closure, facilitating closure without recurrence in large, heavily contaminated wounds. Therapeutic, III.

  17. Vacuum sealing drainage therapy in the presence of an external fixation device

    PubMed Central

    Sun, Dahui; Ju, Weina; Wang, Tiejun; Yu, Tiecheng; Qi, Baochang

    2016-01-01

    Abstract Rationale: Vacuum sealing drainage (VSD) is widely utilized for treating traumatic wounds. Patient concerns: It is particularly difficult and time consuming to use in combination with an external fixator. Diagnoses: This is because the hardware or pins used for fixation interfere with maintaining a seal, resulting in poor adhesion and subsequent air leakage. Interventions: To resolve this problem, we have devised a new method for sealing the wound dressing, while maintaining the required vacuum.When using this technique, a rubber strip is wrapped around each pin in 3 circles outside the plastic drape, and then tightly tied. Outcomes: After completing this procedure, a vacuum is obtained, and any air leakage stops. We employed this technique to treat a cohort of patients in our department over a period of two years, and obtained good healing of soft tissue without air leakage, as well as good clinical outcomes. Lessons: We have observed that patients treated with this method experienced good clinical outcomes without air leakage, and we recommend its use in treating cases where an external fixation device is present. PMID:27861393

  18. Venous drainage of the dorsal sector of the liver: differences between segments I and IX. A study on corrosion casts of the human liver.

    PubMed

    Gadzijev, E M; Ravnik, D; Stanisavljevic, D; Trotovsek, B

    1997-01-01

    The aim of this study was to determine the venous drainage of the dorsal sector of the liver in order to define the differences between segments I and IX and their implications for sectorially and segmentally oriented hepatic surgery. The study was based on corrosion casts of 61 macroscopically healthy livers. The drainage pathways of veins at least 10 mm long and 1 mm wide were evaluated and statistically analysed. On average, 9 veins drained the two segments and three veins from both segments entered the inferior vena cava. In 95% of cases the veins from segment I drained predominantly into the inferior vena cava, whereas in segment IX this pathway was dominant in only 30% of cases. In 64% of cases a vein originating in segment IX entered the right hepatic v. The difference in the venous drainage of the two segments suggests that segment IX partly belongs to the neighbouring segments and may thus be only a paracaval region of the right liver.

  19. Anomalous pulmonary venous connection: An underestimated entity.

    PubMed

    Magalhães, Sara P; Moreno, Nuno; Loureiro, Marília; França, Manuela; Reis, Fernanda; Alvares, Sílvia; Ribeiro, Manuel

    2016-12-01

    Anomalous pulmonary venous connection is an uncommon congenital anomaly in which all (total form) or some (partial form) pulmonary veins drain into a systemic vein or into the right atrium rather than into the left atrium. The authors present one case of total anomalous pulmonary venous connection and two cases of partial anomalous pulmonary venous connection, one of supracardiac drainage into the brachiocephalic vein, and the other of infracardiac anomalous venous drainage (scimitar syndrome). Through the presentation of these cases, this article aims to review the main pulmonary venous developmental defects, highlighting the role of imaging techniques in the assessment of these anomalies. Copyright © 2016 Sociedade Portuguesa de Cardiologia. Publicado por Elsevier España, S.L.U. All rights reserved.

  20. Emergent Embolization of Arterial Bleeding after Vacuum-Assisted Breast Biopsy

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Fischman, Aaron M., E-mail: aaron.fischman@mountsinai.org; Epelboym, Yan, E-mail: yan.epelboym@mssm.edu; Siegelbaum, Robert H., E-mail: rhsiegelbaum@gmail.com

    2012-02-15

    Vacuum-assisted core breast biopsy has become important in evaluating patients with suspicious breast lesions. It has proven to be a relatively safe procedure that in rare cases can result in vascular complications. These are the first reported cases of transcatheter embolization of uncontrolled breast hemorrhage after vacuum-assisted breast biopsy. With increased use of biopsy and larger-gauge devices, breast imaging groups may consider embolotherapy as a safe alternative for treatment of hemorrhage in a select group of patients.

  1. Venous flow during manual lymphatic drainage applied to different regions of the lower extremity in people with and without chronic venous insufficiency: a cross-sectional study.

    PubMed

    Crisóstomo, R S S; Candeias, M S; Armada-da-Silva, P A S

    2017-03-01

    To evaluate the effect of manual lymphatic drainage (MLD) on venous flow when applied to the medial and lateral aspects of the thigh and leg in patients with chronic venous insufficiency (CVI) and healthy subjects. Cross-sectional study. Participants were assessed in a school-based health community attendant service. Fifty-seven subjects participated in this study {mean age: 43 [standard deviation (SD) 14] years, 38 women and 19 men}. Of these, 28 subjects had CVI [mean age 47 (SD 12) years] and 29 subjects did not have CVI [mean age 39 (14) years]. MLD was applied by a certificated physical therapist to the medial and lateral aspects of the thigh and leg. Cross-sectional area; blood flow velocities in the femoral vein, great saphenous vein, popliteal vein and small saphenous vein at baseline and during MLD, measured by duplex ultrasound. Flow volume in the femoral vein increased from baseline [5.19 (SD 3.25)cm 3 /second] when MLD was applied to the medial [7.03 (SD 3.65)cm 3 /second; P≤0.001; mean difference -1.69; 95% confidence interval (CI) -2.42 to -0.97] and lateral [6.16 (SD 3.35)cm 3 /second; P≤0.001; mean difference -1.04; 95% CI -1.70 to -0.39] aspects of the thigh. Venous flow augmentation in the femoral vein and great saphenous vein was higher when MLD was applied to the medial aspect of the thigh (P<0.001), while MLD had a similar effect on venous blood flow regardless of whether it was applied to the medial or the lateral aspect of the leg (P=0.731). MLD increases blood flow in deep and superficial veins. MLD should be applied along the route of the venous vessels for improved venous return. Copyright © 2016 Chartered Society of Physiotherapy. Published by Elsevier Ltd. All rights reserved.

  2. Scrotal antegradesclerotherapy demonstrates anatomical variations on venous drainage in paediatric, adolescent and young adult varicoceles.

    PubMed

    Wong, Y S; Chung, K L Y; Lo, K W Y; Liu, C S W; Fan, T W; Tse, S K S; Tang, P M Y; Chao, N S Y; Liu, K K W; Leung, M W Y

    2014-01-01

    Anatomical variations on venous drainage in varicoceles are under-reported. We report our experience in scrotal antegrade sclerotherapy (SAS) for adolescent varicoceles. Since 2011, 15 consecutive boys with left varicoceles were recruited. Under general anaesthesia, a 5-mm transverse incision was made at scrotal neck, testicular vein was cannulated at pampiniform plexus with venogram performed. Foam sclerosant by mixing sodium tetradecyl sulphate (STS), Lipiodol(®) and air was slowly injected under fluoroscopy. Postoperatively the patients were followed-up for varicocele grading, testicular size, and complications. Median age at operation was 14 (10-19) years. 80 % had grade three varicoceles, 33.3 % had smaller left testis before operation. Intra-operative venogram showed three different anatomical variations. Group I: eleven patients (73.3 %) had single distinct internal spermatic vein; Group II: two patients demonstrated duplication of internal spermatic vein draining into left renal vein; Group III: two patients had pampiniform plexus draining to iliac and/or paraspinal veins. SAS was performed in Group I and II patients. Sclerosant volume injected ranged from 1.5 to 4.5 ml. In Group III patients, surgical ligation of testicular veins was performed rather than SAS to avoid uncontrolled systemic sclerosant spillage. Mean length of stay was 1.13 day. One patient with scrotal haematoma and one other with minor wound dehiscence were managed conservatively. Mean follow-up period was 10.9 (1-22) months. Thirteen patients (86.7 %) achieved varicocele grading ≤ 1. There was no postoperative testicular atrophy, hydrocele and epididymo-orchitis. Scrotal antegrade sclerotherapy using STS foam is a safe and effective treatment for adolescent varicoceles. Anatomical variations on venous drainage in varicoceles are common.

  3. Vacuum-assisted closure therapy in the management of lung abscess.

    PubMed

    Sziklavari, Zsolt; Ried, Michael; Hofmann, Hans-Stefan

    2014-09-06

    Despite significant advances in the treatment of thoracic infections, complex lung abscess remains a problem in modern thoracic surgery. We describe the novel application of vacuum-assisted closure for the treatment of a lung abscess. The technical details and preliminary results are reported. After the initial failed conservative treatment of an abscess, minimally invasive surgical intervention was performed with vacuum-assisted closure. The vacuum sponges were inserted in the abscess cavity at the most proximal point to the pleural surface. The intercostal space of the chest wall above the entering place was secured by a soft tissue retractor. The level of suction was initially set to 100 mm Hg, with a maximum suction of 125 mm Hg. The sponge was changed once on the 3rd postoperative day. The abscess cavity was rapidly cleaned and decreased in size. The mini-thoracotomy could be closed on the 9th postoperative day. Closure of the cavity was simple, without any short- or long-term treatment failure. This technique reduced the trauma associated with the procedure. The patient was discharged on the 11th postoperative day. Vacuum-assisted closure systems should be considered for widespread use as an alternative option for the treatment of complicated pulmonary abscess in elderly, debilitated, immunocompromised patients after failed conservative treatment.

  4. In vitro validation of a self-driving aortic-turbine venous-assist device for Fontan patients.

    PubMed

    Pekkan, Kerem; Aka, Ibrahim Basar; Tutsak, Ece; Ermek, Erhan; Balim, Haldun; Lazoglu, Ismail; Turkoz, Riza

    2018-03-11

    Palliative repair of single ventricle defects involve a series of open-heart surgeries where a single-ventricle (Fontan) circulation is established. As the patient ages, this paradoxical circulation gradually fails, because of its high venous pressure levels. Reversal of the Fontan paradox requires an extra subpulmonic energy that can be provided through mechanical assist devices. The objective of this study was to evaluate the hemodynamic performance of a totally implantable integrated aortic-turbine venous-assist (iATVA) system, which does not need an external drive power and maintains low venous pressure chronically, for the Fontan circulation. Blade designs of the co-rotating turbine and pump impellers were developed and 3 prototypes were manufactured. After verifying the single-ventricle physiology at a pulsatile in vitro circuit, the hemodynamic performance of the iATVA system was measured for pediatric and adult physiology, varying the aortic steal percentage and circuit configurations. The iATVA system was also tested at clinical off-design scenarios. The prototype iATVA devices operate at approximately 800 revolutions per minute and extract up to 10% systemic blood from the aorta to use this hydrodynamic energy to drive a blood turbine, which in turn drives a mixed-flow venous pump passively. By transferring part of the available energy from the single-ventricle outlet to the venous side, the iATVA system is able to generate up to approximately 5 mm Hg venous recovery while supplying the entire caval flow. Our experiments show that a totally implantable iATVA system is feasible, which will eliminate the need for external power for Fontan mechanical venous assist and combat gradual postoperative venous remodeling and Fontan failure. Copyright © 2018 The American Association for Thoracic Surgery. Published by Elsevier Inc. All rights reserved.

  5. To mix or not to mix venous blood samples collected in vacuum tubes?

    PubMed

    Parenmark, Anna; Landberg, Eva

    2011-09-08

    There are recommendations to mix venous blood samples by inverting the tubes immediately after venipuncture. Though mixing allows efficient anticoagulation in plasma tubes and fast initiation of coagulation in serum tubes, the effect on laboratory analyses and risk of haemolysis has not been thoroughly evaluated. Venous blood samples were collected by venipuncture in vacuum tubes from 50 patients (10 or 20 patients in each group). Four types of tubes and 18 parameters used in routine clinical chemistry were evaluated. For each patient and tube, three types of mixing strategies were used: instant mixing, no mixing and 5 min of rest followed by mixing. Most analyses did not differ significantly in samples admitted to different mixing strategies. Plasma lactate dehydrogenase and haemolysis index showed a small but significant increase in samples omitted to instant mixing compared to samples without mixing. However, in one out of twenty non-mixed samples, activated partial thromboplastin time was seriously affected. These results indicate that mixing blood samples after venipuncture is not mandatory for all types of tubes. Instant mixing may introduce interference for those analyses susceptible to haemolysis. However, tubes with liquid-based citrate buffer for coagulation testing should be mixed to avoid clotting.

  6. [Horseshoe lung with normal pulmonary venous return].

    PubMed

    Gondra Sangroniz, A; Elorz Lambarri, J; Villar Alvarez, M A; Lecumberri Cortes, I; Ayala Curiel, J

    2010-09-01

    Horseshoe lung is a rare congenital anomaly characterised by a midline isthmus of pulmonary parenchyma connecting the posterior basal segments of the lungs behind the heart in conjunction with unilateral pulmonary hypoplasia. Of all cases, 80% are associated with scimitar syndrome, consisting of right anomalous pulmonary venous drainage, pulmonary hypoplasia of the right lung and systemic arterial perfusion to some lung areas. A six year old girl who had recurrent lower respiratory infections since birth. Chest Rx, angioCT and MR showed: hypoplasia of the right lung, dextrocardia and pulmonary isthmus bridging both lungs behind the pericardium. The right hypoplastic lung had little systemic supply coming from the abdominal aorta. The right pulmonary artery was hypoplastic. The right pulmonary venous drainage was normal. We present a case of horseshoe lung without abnormal venous drainage. 2010 Asociación Española de Pediatría. Published by Elsevier Espana. All rights reserved.

  7. Cardiac veins: collateral venous drainage pathways in chronic hemodialysis patients.

    PubMed

    Ozmen, Evrim; Algin, Oktay

    2016-07-12

    Venous anomalies are diagnostic and therapeutic challenges. Subclavian or superior vena cava stenosis can be developed and venous return can be achieved via cardiac veins and coronary sinus in patients with central venous catheter for long-term hemodialysis. These types of abnormalities are not extremely rare especially in patients with a history of central venous catheter placement. Detection of these anomalies and subclavian vein stenosis before the surgical creation of hemodialysis fistulae or tunneled central venous catheter placement may prevent unnecessary interventions in those patients. Multidetector computed tomography (MDCT) technique can give further information when compared with fluoroscopy or digital subtraction angiography in the management of these patients. This case report describes interesting aspects of central vein complications in hemodialysis patients. As a conclusion, there are limited data about thoracic venous return, and further prospective studies with large patient number are required. MDCT with 3D reconstruction is particularly useful for the accurate evaluation of venous patency, variations, and collateral circulation. Also it is an excellent tool for choosing and planning treatment.

  8. Risk factors for anal sphincter tears in vacuum-assisted delivery.

    PubMed

    Ryman, P; Ahlberg, M; Ekéus, C

    2015-10-01

    The aim of the present study was to describe the prevalence of anal sphincter tears (AST) in relation to obstetric management and technique during vacuum extraction deliveries (VE) (re: indications, the station of the fetal head at application of the cup, number of tractions, the length for the extraction, cup detachments, pain relief, episiotomy, fetal presentation, and experience of the operator) as well as maternal and infant anthropometrics. Descriptive study. Data on six hundred vacuum extraction deliveries were consecutively collected from six different delivery units in Sweden. Each unit contributed with data on 100 deliveries. The final study population included 596 women who delivered by vacuum extraction. There was no correlation between the management of the vacuum extraction and risk for anal sphincter tear. Women from Africa had nearly a fourfold risk for anal sphincter tear during vacuum-assisted delivery compared with Swedish-born women (OR 3.82 CI 1.47-9.89). Compared with infants with birth weight less than 4000 g, birth weight above 4000 g was associated with increased risk of AST (OR 1.87 CI 1.06-3.28). In this study, the obstetric management in VE-assisted deliveries did not impact the risk of AST. Copyright © 2015 Elsevier B.V. All rights reserved.

  9. Capillary filtration in venous hypertension. Comparison between the vacuum suction chamber (VSC) device and straingauge phlethysmography.

    PubMed

    Belcaro, G; Rulo, A; Renton, S

    1992-01-01

    To evaluate capillary filtration a group of normal subjects and two groups of subjects with venous incompetence (50 with deep and 50 with superficial incompetence) were studied with the vacuum suction chamber (VSC) device applied onto the internal perimalleolar region. This method was compared with straingauge plethysmography rate of ankle swelling (RAS). By the VSC the time taken for the weal to disappear (VSC time) was considered indicative of capillary filtration. The values obtained with the two methods were well related (r < 0.742) and there was a good separation between patients and normals. The separation between the two groups of patients was significantly better (p < 0.05) with the VSC time. In conclusion VSC time is a good indication of capillary filtration in comparison with straingauge plethysmography RAS. It may be used to assess variations in capillary filtration in venous hypertension and possibly to follow up the effects of treatments.

  10. Massive air embolism in a Fontan patient.

    PubMed

    Matte, Gregory S; Kussman, Barry D; Wagner, Joseph W; Boyle, Sharon L; Howe, Robert J; Pigula, Frank A; Emani, Sitaram M

    2011-06-01

    Most institutions performing cardiopulmonary bypass for congenital heart disease patients use an integrated hard shell cardiotomy and venous reservoir attached to an oxygenator. It is of paramount importance that the integrated reservoir be vented so as not to cause pressurization. A pressurized sealed cardiotomy has been reported to occur secondary to issues with vacuum assisted venous drainage systems as well as improper venting in general. We report a case of air embolus caused by retrograde propulsion of air through the venous line secondary to a pressurized cardiotomy reservoir in a patient with Fontan circulation. The mechanism of cardiotomy pressurization is described, and the scenario simulated in a mock circuit.

  11. The cost effectiveness of vacuum-assisted versus core-needle versus surgical biopsy of breast lesions.

    PubMed

    Fernández-García, P; Marco-Doménech, S F; Lizán-Tudela, L; Ibáñez-Gual, M V; Navarro-Ballester, A; Casanovas-Feliu, E

    To determine the cost effectiveness of breast biopsy by 9G vacuum-assisted guided by vertical stereotaxy or ultrasonography in comparison with breast biopsy by 14G core-needle biopsy and surgical biopsy. We analyzed a total of 997 biopsies (181 vacuum-assisted, 626 core, and 190 surgical biopsies). We calculated the total costs (indirect and direct) of the three types of biopsy. We did not calculate intangible costs. We measured the percentage of correct diagnoses obtained with each technique. To identify the most cost-effective option, we calculated the mean ratios for the three types of biopsies. Total costs were €225.09 for core biopsy, €638.90 for vacuum-assisted biopsy, and €1780.01 for surgical biopsy. The overall percentage of correct diagnoses was 91.81% for core biopsy, 94.03% for vacuum-assisted biopsy, and 100% for surgical biopsy; however, these differences did not reach statistical significance (p=0.3485). For microcalcifications, the percentage of correct diagnoses was 50% for core biopsy and 96.77% for vacuum-assisted biopsy (p<0.0001). For nodules, there were no significant differences among techniques. The mean cost-effectiveness ratio considering all lesions was 2.45 for core biopsy, 6.79 for vacuum-assisted biopsy, and 17.80 for surgical biopsy. Core biopsy was the dominant option for the diagnosis of suspicious breast lesions in general. However, in cases with microcalcifications, the low percentage of correct diagnoses achieved by core biopsy (50%) advises against its use in this context, where vacuum-assisted biopsy would be the technique of choice because it is more cost-effective than surgical biopsy, the other technique indicated for biopsying microcalcifications. Copyright © 2016 SERAM. Publicado por Elsevier España, S.L.U. All rights reserved.

  12. Variant adrenal venous anatomy in 546 laparoscopic adrenalectomies.

    PubMed

    Scholten, Anouk; Cisco, Robin M; Vriens, Menno R; Shen, Wen T; Duh, Quan-Yang

    2013-04-01

    Knowing the types and frequency of adrenal vein variants would help surgeons identify and control the adrenal vein during laparoscopic adrenalectomy. To establish the surgical anatomy of the main vein and its variants for laparoscopic adrenalectomy and to analyze the relationship between variant adrenal venous anatomy and tumor size, pathologic diagnosis, and operative outcomes. In a retrospective review of patients at a tertiary referral hospital, 506 patients underwent 546 consecutive laparoscopic adrenalectomies between April 22, 1993, and October 21, 2011. Patients with variant adrenal venous anatomy were compared with patients with normal adrenal venous anatomy regarding preoperative variables (patient and tumor characteristics [size and location] and clinical diagnosis), intraoperative variables (details on the main adrenal venous drainage, any variant venous anatomy, duration of operation, rate of conversion to hand-assisted or open procedure, and estimated blood loss), and postoperative variables (transfusion requirement, reoperation for bleeding, duration of hospital stay, and histologic diagnosis). Laparoscopic adrenalectomy. Prevalence of variant adrenal venous anatomy and its relationship to tumor characteristics, pathologic diagnosis, and operative outcomes. Variant venous anatomy was encountered in 70 of 546 adrenalectomies (13%). Variants included no main adrenal vein identifiable (n = 18), 1 main adrenal vein with additional small veins (n = 11), 2 adrenal veins (n = 20), more than 2 adrenal veins (n = 14), and variants of the adrenal vein drainage to the inferior vena cava and hepatic vein or of the inferior phrenic vein (n = 7). Variants occurred more often on the right side than on the left side (42 of 250 glands [17%] vs. 28 of 296 glands [9%], respectively; P = .02). Patients with variant anatomy compared with those with normal anatomy had larger tumors (mean, 5.1 vs 3.3 cm, respectively; P < .001), more pheochromocytomas (24 of 70 [35%] vs

  13. Early removal of urethral catheter with suprapubic tube drainage versus urethral catheter drainage alone after robot-assisted laparoscopic radical prostatectomy.

    PubMed

    Prasad, Sandip M; Large, Michael C; Patel, Amit R; Famakinwa, Olufenwa; Galocy, R Matthew; Karrison, Theodore; Shalhav, Arieh L; Zagaja, Gregory P

    2014-07-01

    Retrospective single institution data suggest that postoperative pain after robot-assisted laparoscopic radical prostatectomy is decreased by early removal of the urethral catheter with suprapubic tube drainage. In a randomized patient population we determined whether suprapubic tube drainage with early urethral catheter removal would improve postoperative pain compared with urethral catheter drainage alone. Men with a body mass index of less than 40 kg/m(2) who had newly diagnosed prostate cancer and elected robot-assisted laparoscopic radical prostatectomy were included in analysis. Block randomization by surgeon was used and randomization assignment was done after completing the urethrovesical anastomosis. In patients assigned to suprapubic tube drainage the urethral catheter was removed on postoperative day 1 and all catheters were removed on postoperative day 7. Visual analog pain scale and satisfaction questionnaires were administered on postoperative days 0, 1 and 7. A total of 29 patients were randomized to the urethral catheter vs 29 to the suprapubic tube plus early urethral catheter removal at the time of interim futility analysis. Mean visual analog pain scale scores did not differ between the groups at any time point and a similar percent of patients cited the catheter as the greatest bother with nonsignificant differences in treatment related satisfaction. Complications during postoperative week 1 did not vary between the groups. Based on interim results the trial was terminated due to lack of effect. Patients randomized to suprapubic tube vs urethral catheter drainage for the week after prostatectomy had similar pain, catheter related bother and treatment related satisfaction in the perioperative period. We no longer routinely offer suprapubic tube drainage with early urethral catheter removal at our institution. Copyright © 2014 American Urological Association Education and Research, Inc. Published by Elsevier Inc. All rights reserved.

  14. 21. Engine identified as a 'single cylinder vacuum assist engine ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    21. Engine identified as a 'single cylinder vacuum assist engine for Tod tandem compound engine' showing compressor. - Carnegie Steel-Ohio Works, Steam Engines, 912 Salt Springs Road, Youngstown, Mahoning County, OH

  15. Focal hepatic fatty infiltration in the posterior edge of the medial segment associated with aberrant gastric venous drainage: CT, US, and MR findings

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Kawamori, Yashuiro; Matsui, Osamu; Takahashi, S.

    1996-05-01

    The purpose of this study is to demonstrate the relation between focal hepatic fatty infiltration and aberrant gastric venous drainage (AGVD) in the posterior edge of the medial segment (PEMS) of the liver and we present two cases of focal hepatic fatty infiltration with AGVD in the PEMS and discuss their imaging features. In both cases the focal fatty infiltration areas were hyperechoic on sonography, hypodense on CT, and hyperintense on T1-weighted MRI. Computed tomography during arterial portography (CTAP) showed nodular perfusion defects corresponding to the areas in both cases, and early enhancement of the area was observed with dynamicmore » MRI in one case. Although the findings on CTAP and dynamic MRI suggested a neoplastic nature for the lesions, focal fatty infiltration was confirmed with surgical resection in one case and with imaging follow-up in the other. Aberrant gastric venous drainage into the area was demonstrated on arteriography in both cases. The variation in blood supply caused by AGVD may play an important role in fatty metabolism in the PENIS of the liver and may influence imaging features. 9 refs., 2 figs.« less

  16. The echocardiographic diagnosis of totally anomalous pulmonary venous connection in the fetus.

    PubMed

    Allan, L D; Sharland, G K

    2001-04-01

    Infants with isolated totally anomalous pulmonary venous return often present severely decompensated, such that they are at high risk for surgical repair. On the other hand, if surgical repair can be safely accomplished, the outlook is usually good. Thus prenatal diagnosis would be expected to improve the prognosis for the affected child. To describe the features of isolated totally anomalous pulmonary venous drainage in the fetus. Four fetuses with isolated totally anomalous pulmonary venous connection were identified and the echocardiographic images reviewed. Measurements of the atrial and ventricular chambers and both great arteries were made and compared with normal values. Referral centre for fetal echocardiography. There were two cases of drainage to the coronary sinus, one to the right superior vena cava, and one to the inferior vena cava. Right heart dilatation relative to left heart structures was a feature of two cases early on, and became evident in some ratios late in pregnancy in the remaining two. Ventricular and great arterial disproportion in the fetus can indicate a diagnosis of totally anomalous pulmonary venous connection above the diaphragm. However, in the presence of an atrial septal defect or with infradiaphragmatic drainage, right heart dilatation may not occur until late in pregnancy. The diagnosis of totally anomalous pulmonary venous drainage in fetal life can only be reliably excluded by direct examination of pulmonary venous blood flow entering the left atrium on colour or pulsed flow mapping.

  17. 20. Engine identified as a 'single cylinder vacuum assist engine ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    20. Engine identified as a 'single cylinder vacuum assist engine for the Tod tandem compound engine' showing crank end. - Carnegie Steel-Ohio Works, Steam Engines, 912 Salt Springs Road, Youngstown, Mahoning County, OH

  18. 19. Engine identified as a single cylinder vacuum assist engine ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    19. Engine identified as a single cylinder vacuum assist engine for the Filer and Stowell 15-inch continuous mill. - Carnegie Steel-Ohio Works, Steam Engines, 912 Salt Springs Road, Youngstown, Mahoning County, OH

  19. Massive Air Embolism in a Fontan Patient

    PubMed Central

    Matte, Gregory S.; Kussman, Barry D.; Wagner, Joseph W.; Boyle, Sharon L.; Howe, Robert J.; Pigula, Frank A.; Emani, Sitaram M.

    2011-01-01

    Abstract: Most institutions performing cardiopulmonary bypass for congenital heart disease patients use an integrated hard shell cardiotomy and venous reservoir attached to an oxygenator. It is of paramount importance that the integrated reservoir be vented so as not to cause pressurization. A pressurized sealed cardiotomy has been reported to occur secondary to issues with vacuum assisted venous drainage systems as well as improper venting in general. We report a case of air embolus caused by retrograde propulsion of air through the venous line secondary to a pressurized cardiotomy reservoir in a patient with Fontan circulation. The mechanism of cardiotomy pressurization is described, and the scenario simulated in a mock circuit. PMID:21848177

  20. [Vacuum-assisted therapy for various wound types including diabetic foot ulcer].

    PubMed

    Farah, Raymond; Gantus, Maher; Kogan, Leonid

    2011-03-01

    Vacuum is a noninvasive system that creates a localized controlled negative pressure environment. In this study, vacuum was provided by the V.A.C. Therapy system, which promotes wound healing by delayed primary or secondary intention through creating a moist wound environment, preparing the wound bed for closure, reducing edema, and promoting formation and perfusion of granulation tissue. Vacuum-assisted closure therapy is indicated for use in all care settings and for a variety of wound types including diabetic foot ulcers. The purpose of this study was to evaluate safety and clinical efficacy of negative pressure wound therapy (NPWT) compared with advanced moist wound therapy and standard treatment to treat foot ulcers in diabetic patients. This trial enrolled 43 patients; most of them were diabetic patients at any age with various skin ulcers and diabetic foot. These patients were divided into two groups, 17 patients were treated with vacuum and the 26 patients in the control group were treated with standard therapy including debridement. A greater proportion of foot and skin ulcers achieved complete ulcer closure with vacuum-assisted therapy p<0.001 compared with the standard therapy. Vacuum therapy significantly decreased the duration and frequency of admission p=0.032 and decreased the rate of amputation p<0.001. Results of our trial support other studies and demonstrate that vacuum is as safe as and more efficacious than standard therapy in the treatment of diabetic foot ulcers. A significantly greater number of patients achieved complete ulcer closure and granulation tissue formation with this therapy. The study group showed a significant reduction in the median time needed to heal ulcers, reduction of the number of admissions and amputation frequency.

  1. Automatic Control of Veno-Venous Extracorporeal Lung Assist.

    PubMed

    Kopp, Ruedger; Bensberg, Ralf; Stollenwerk, Andre; Arens, Jutta; Grottke, Oliver; Walter, Marian; Rossaint, Rolf

    2016-10-01

    Veno-venous extracorporeal lung assist (ECLA) can provide sufficient gas exchange even in most severe cases of acute respiratory distress syndrome. Commercially available systems are manually controlled, although an automatically controlled ECLA could allow individualized and continuous adaption to clinical requirements. Therefore, we developed a demonstrator with an integrated control algorithm to keep continuously measured peripheral oxygen saturation and partial pressure of carbon dioxide constant by automatically adjusting extracorporeal blood and gas flow. The "SmartECLA" system was tested in six animal experiments with increasing pulmonary hypoventilation and hypoxic inspiratory gas mixture to simulate progressive acute respiratory failure. During a cumulative evaluation time of 32 h for all experiments, automatic ECLA control resulted in a peripheral oxygen saturation ≥90% for 98% of the time with the lowest value of 82% for 15 s. Partial pressure of venous carbon dioxide was between 40 and 49 mm Hg for 97% of the time with no value <35 mm Hg or >49 mm Hg. With decreasing inspiratory oxygen concentration, extracorporeal oxygen uptake increased from 68 ± 25 to 154 ± 34 mL/min (P < 0.05), and reducing respiratory rate resulted in increasing extracorporeal carbon dioxide elimination from 71 ± 37 to 92 ± 37 mL/min (P < 0.05). The "SmartECLA" demonstrator allowed reliable automatic control of the extracorporeal circuit. Proof of concept could be demonstrated for this novel automatically controlled veno-venous ECLA circuit. Copyright © 2015 International Center for Artificial Organs and Transplantation and Wiley Periodicals, Inc.

  2. Evaluation of a Prototype Hybrid Vacuum Pump to Provide Vacuum-Assisted Suspension for Above-Knee Prostheses

    PubMed Central

    Major, Matthew J.; Caldwell, Ryan; Fatone, Stefania

    2015-01-01

    Vacuum-assisted suspension (VAS) of prosthetic sockets utilizes a pump to evacuate air from between the prosthetic liner and socket, and are available as mechanical or electric systems. This technical note describes a hybrid pump that benefits from the advantages of mechanical and electric systems, and evaluates a prototype as proof-of-concept. Cyclical bench testing of the hybrid pump mechanical system was performed using a materials testing system to assess the relationship between compression cycles and vacuum pressure. Phase 1 in vivo testing of the hybrid pump was performed by an able-bodied individual using prosthesis simulator boots walking on a treadmill, and phase 2 involved an above-knee prosthesis user walking with the hybrid pump and a commercial electric pump for comparison. Bench testing of 300 compression cycles produced a maximum vacuum of 24 in-Hg. In vivo testing demonstrated that the hybrid pump continued to pull vacuum during walking, and as opposed to the commercial electric pump, did not require reactivation of the electric system during phase 2 testing. The novelty of the hybrid pump is that while the electric system provides rapid, initial vacuum suspension, the mechanical system provides continuous air evacuation while walking to maintain suspension without reactivation of the electric system, thereby allowing battery power to be reserved for monitoring vacuum levels. PMID:27462383

  3. Peripheral venous catheter insertion simulation training: A randomized controlled trial comparing performance after instructor-led teaching versus peer-assisted learning.

    PubMed

    Pelloux, Sophie; Grégoire, Arnaud; Kirmizigul, Patrice; Maillot, Sandrine; Bui-Xuan, Bernard; Llorca, Guy; Boet, Sylvain; Lehot, Jean-Jacques; Rimmelé, Thomas

    2017-12-01

    Peripheral venous catheter insertion is a procedural skill that every medical student should master. Training is often limited to a small number of students and is poorly evaluated. The objective of this study was to evaluate the performance of peer-assisted learning in comparison to instructor-led teaching for peripheral venous catheter insertion training. Students were randomized to the control group attending a traditional instructor-led training session (slideshow and demonstration by an anesthetist instructor, followed by training on a procedural simulator) or to the test group attending a peer-assisted training session (slideshow and demonstration video-recorded by the same instructor, followed by training on a procedural simulator). The primary endpoint was the performance of peripheral venous catheter insertion, assessed on procedural simulator one week later by blinded experts using a standardized 20-item grid. Students self-evaluated their confidence levels using a numeric 10-point scale. Eighty-six students were included, 73 of whom attended the assessment session. The median performance score was 12/20 [8-15] in the instructor-led teaching group versus 13/20 [11-15] in the peer-assisted learning group (P=0.430). Confidence levels improved significantly after the assessment session and were significantly higher in the peer-assisted learning group (7.6/10 [7.0-8.0] versus 7.0/10 [5.0-8.0], P=0.026). Peer-assisted learning is effective for peripheral venous catheter insertion training and can be as effective as instructor-led teaching. Given the large number of students to train, this finding is important for optimizing the cost-effectiveness of peripheral venous catheter insertion training. Copyright © 2017 Société française d’anesthésie et de réanimation (Sfar). Published by Elsevier Masson SAS. All rights reserved.

  4. Evaluation of anterior third of superior sagittal sinus in normal population: Identifying the subgroup with dominant drainage.

    PubMed

    Sahoo, Sushanta K; Ghuman, Mandeep S; Salunke, Pravin; Vyas, Sameer; Bhar, Rahat; Khandelwal, N K

    2016-01-01

    The ligation and transection of anterior third of superior sagittal sinus (AT-SSS) is an important step to approach anterior skull base lesions. Some clinical studies have shown frontal lobe venous infarct following such surgical procedures questioning the safety of its ligation. We have studied the variations in venous drainage patterns to AT-SSS in the normal population using postcontrast magnetic resonance venogram (MRV). A novel scoring system to recognize the subgroup with dominant venous drainage from frontal lobes has been described. In this study, 60 three-dimensional contrast-enhanced (CE) MRVs were obtained from those cases being evaluated for a headache not harboring any intracranial mass lesion. The AT-SSS with all its draining veins was studied in detail. Morphology of individual veins such as length, caliber, tributaries, and angulation with AT-SSS was studied, and a numerical value of 0 or 1 was assigned for each of the above parameters. Summing up these scores derived from the individual cortical veins quantified the drainage of AT-SSS. There are 3-4 veins on either side draining to AT-SSS. Barely, 3% of the veins had > 3 tributaries. Only 6.6% of veins had a caliber >3 mm, and 16.5% drained at acute angles to AT-SSS. About 26% of the veins did cross at least half of the lateral frontal lobe. We found in 26 individuals the AT-SSS score was 0-2, in 22 it was 3-5 and, in only in 12 (20%) the score was 6 or more (dominant drainage). There are anatomical variations in venous drainage of frontal lobes into AT-SSS. Those with dominant drainage are likely to develop venous congestion and complications if sacrificed. It is possible to identify these individuals on the basis of venous drainage pattern as shown in CE-MRV.

  5. MR Elastography Can Be Used to Measure Brain Stiffness Changes as a Result of Altered Cranial Venous Drainage During Jugular Compression.

    PubMed

    Hatt, A; Cheng, S; Tan, K; Sinkus, R; Bilston, L E

    2015-10-01

    Compressing the internal jugular veins can reverse ventriculomegaly in the syndrome of inappropriately low pressure acute hydrocephalus, and it has been suggested that this works by "stiffening" the brain tissue. Jugular compression may also alter blood and CSF flow in other conditions. We aimed to understand the effect of jugular compression on brain tissue stiffness and CSF flow. The head and neck of 9 healthy volunteers were studied with and without jugular compression. Brain stiffness (shear modulus) was measured by using MR elastography. Phase-contrast MR imaging was used to measure CSF flow in the cerebral aqueduct and blood flow in the neck. The shear moduli of the brain tissue increased with the percentage of blood draining through the internal jugular veins during venous compression. Peak velocity of caudally directed CSF in the aqueduct increased significantly with jugular compression (P < .001). The mean jugular venous flow rate, amplitude, and vessel area were significantly reduced with jugular compression, while cranial arterial flow parameters were unaffected. Jugular compression influences cerebral CSF hydrodynamics in healthy subjects and can increase brain tissue stiffness, but the magnitude of the stiffening depends on the percentage of cranial blood draining through the internal jugular veins during compression—that is, subjects who maintain venous drainage through the internal jugular veins during jugular compression have stiffer brains than those who divert venous blood through alternative pathways. These methods may be useful for studying this phenomenon in patients with the syndrome of inappropriately low-pressure acute hydrocephalus and other conditions. © 2015 by American Journal of Neuroradiology.

  6. Fontan completion in patients with atrial isomerism and separate hepatic venous drainage.

    PubMed

    Nakata, Tomohiro; Fujimoto, Yoshifumi; Hirose, Keiichi; Osaki, Masaki; Tosaka, Yuko; Ide, Yujiro; Tachi, Maiko; Sakamoto, Kisaburo

    2010-06-01

    Fontan completion in patients with atrial isomerism, in which the inferior vena cava (IVC) and the hepatic vein (HV) drain separately, is technically challenging. Herein, we review our surgical approach to these patients. The medical records of 50 consecutive patients with atrial isomerism who underwent Fontan completion between 1998 and 2008 were reviewed retrospectively. Separate HV drainage was present in 17 patients. Patients with interrupted IVC were excluded. Patient characteristics were as follows: median age, 26 months (range 15-149); median weight, 9.6 kg (range 8.1-47.2); right atrial isomerism, 16 patients; and left atrial isomerism, one. The IVC and the separate HV at the level of diaphragm were contralateral in 16 patients, and ipsilateral in one. The surgical procedures for directing blood flow from the IVC and the separate HV to the pulmonary arteries were as follows: en bloc resection of the IVC and the HV and anastomosing these veins to an extracardiac conduit in 10 patients; connecting the IVC to the HV in a side-to-side fashion before anastomosing them to an extracardiac conduit in one; and lateral tunnel in another. When the IVC and the HV were widely separated by the vertebrae, we chose an intra-extracardiac conduit (intra-atrial septation) in four patients and an extracardiac conduit for the IVC and the right HV and lateral tunnel for the separate left HV in one. There was no mortality. Five re-operations were performed (pacemaker in two patients; one each of fenestration, release of outflow obstruction and ligation of collateral arteries). Sixteen patients underwent follow-up catheterisation, which revealed central venous pressure of 12.0 + or - 2.0 mmHg and arterial oxygen saturation of 92% + or - 6%. The mid-term results of the Fontan completion in patients with atrial isomerism and separate HV drainage were excellent. The distance between the IVC and the separate HV and the position of the vertebrae should be considered when choosing a

  7. Intracranial developmental venous anomaly: is it asymptomatic?

    PubMed

    Puente, A Bolívar; de Asís Bravo Rodríguez, F; Bravo Rey, I; Romero, E Roldán

    2018-03-16

    Intracranial developmental venous anomalies are the most common vascular malformation. In the immense majority of cases, these anomalies are asymptomatic and discovered incidentally, and they are considered benign. Very exceptionally, however, they can cause neurological symptoms. In this article, we present three cases of patients with developmental venous anomalies that presented with different symptoms owing to complications derived from altered venous drainage. These anomalies were located in the left insula, right temporal lobe, and cerebellum. The exceptionality of the cases presented as well as of the images associated, which show the mechanism through which the symptoms developed, lies in the low incidence of symptomatic developmental venous anomalies reported in the literature. Copyright © 2018 SERAM. Publicado por Elsevier España, S.L.U. All rights reserved.

  8. Development of Subischial Prosthetic Sockets with Vacuum-Assisted Suspension for Highly Active Persons with Transfemoral Amputations

    DTIC Science & Technology

    2012-10-01

    materials to facilitate dissemination of this technique. 15. SUBJECT TERMS Transfemoral amputation, sub-ischial socket, prosthesis , vacuum-assisted...an appropriate mechanical pump to create suitable vacuum for suspension of the prosthesis ...sockets of highly active prosthesis users

  9. Development of Subischial Prosthetic Sockets with Vacuum-Assisted Suspension for Highly Active Persons with Transfemoral Amputations

    DTIC Science & Technology

    2014-10-01

    Award Number: W81XWH-10-1-0744 TITLE: Development of Subischial Prosthetic Sockets with Vacuum...REPORT TYPE Annual 3. DATES COVERED 15 Sep 2013 – 14 Sep 2014 4. TITLE AND SUBTITLE Development of Subischial Prosthetic Sockets with Vacuum...to develop a highly flexible sub-ischial prosthetic socket with assisted-vacuum suspension for highly active persons with transfemoral amputation. The

  10. Protection of polyphenols in blueberry juice by vacuum-assisted block freeze concentration.

    PubMed

    Orellana-Palma, Patricio; Petzold, Guillermo; Pierre, Lissage; Pensaben, José Manuel

    2017-11-01

    Block freeze concentration allows produces high-quality cryoconcentrates with important protection of valuable components from fresh fruit juices. The aim of this study was to investigate the use of vacuum-assisted block freeze concentration under different experimental conditions to protect polyphenols in the elaboration of concentrated blueberry juice. Fresh blueberry juice was radial or unidirectional frozen at -20 and -80 °C for 12 h and vacuum process was performed at 80 kPa during 120 min. Results showed a significant solute increased in the concentrated fraction in all treatments, and the best treatment was - 20 °C/unidirectional with a value of ≈63 °Brix, equivalent to an increase of 3.8 times in the total polyphenol content (76% of retention). The color of concentrated samples was darker than the initial sample, with ΔE* values of >25 CIELab units in all treatments. The vacuum-assisted block freeze concentrations was an effective technology for protecting polyphenols and obtain a concentrated with a higher concentration of solids from blueberry juice, as well as interesting values of process parameters. Copyright © 2017 Elsevier Ltd. All rights reserved.

  11. [Assessment of vacuum-assisted vaginal delivery in a frank breech presentation].

    PubMed

    Bleu, G; Deruelle, P; Demetz, J; Michel, S; Dufour, P; Depret, S; Subtil, D

    2015-02-01

    After verification of the eligibility criteria and with an obstetrician familiar with the specific maneuvers likely to be needed, vaginal delivery of breech presentations is possible. If problems arise during the active pushing phase of labor, vacuum extraction has been described in the literature for this uncommon condition with limited series. The aim of this study is to assess retrospectively vacuum extraction in frank breech presentation in our center. This retrospective study of trials of vaginal delivery of fetuses in breech presentation at term compares cases according to whether they did or did not use a vacuum extraction. During a two-year period, 83 patients, whom had trials of vaginal delivery in breech presentations, reached the active pushing/bearing down stage after complete cervical dilatation. Vacuum assistance was applied in six of these (7.2 %). The failure rate for vaginal delivery was significantly higher in the group with compared to without vacuum extraction (33.3 % versus 6.5 %, P<0.05). Moreover, the mean pH at birth was significantly lower in the group with vacuum extraction (7.12±0.11 versus 7.20±0.08, P<0.05), and these infants more frequently had deep cutaneous injuries (66.7 % versus 26.0 %, P<0.05). In fetuses in breech presentation, when vaginal delivery failed, it seems to be safer for the fetuses to perform caesarean section rather than attempt vacuum extraction. Copyright © 2015 Elsevier Masson SAS. All rights reserved.

  12. Improved vacuum sealing drainage for treatment of surgical site infection following posterior spinal internal fixation

    PubMed Central

    Zhang, Hengyan; Li, Qiyi

    2018-01-01

    Abstract Rationale: Surgical site infection (SSI) following spine surgeries involving internal fixation often require removing the instrument; however, this can cause spinal instability. Previous reports have demonstrated the usefulness of vacuum sealing drainage (VSD) therapy, but the cases require wound opening, aseptic condition to replace the VSD device, and a secondary operation to close the wound. Thus, to improve the VSD treatment and develop a maneuverable procedure, make sense in spine surgery. Patients concerns: A 59-year-old male patient with a T12 vertebral fracture was affected by SSIs after spinal osteotomy with internal fixation. Diagnoses: The patient complained of wound exudation and had a fever 3 weeks after posterior spinal surgery. Initial serum investigations showed elevated white blood cell count and bacterial cultures of wound exudate were positive for Enterococcus faecalis. Therefore, SSI is confirmed. Interventions: The infection was not controlled after 2 debridements, so the patient was treated with VSD treatment. The VSD foam dressings containing a drainage tube were placed into the wound from the exudation site of the wound until they contacted the internal fixation devices. After covering external fixation devices, continuous drainage was performed for 24 h. The VSD device was replaced every 4 to 5 days until the wound effusion stopped. All of the operations were performed at the bedside without complex manipulation or secondary closure under harsh aseptic condition. Outcomes: Wound exudation decreased remarkably and the infection was controlled 2 weeks after the application of VSD treatment. After 5 weeks, inflammatory indicators all decreased to normal levels and the exudate of the wound had stopped. The VSD treatment was then terminated and the drainage site of the wound was sutured. After 7 weeks, complete wound healing was achieved and no infection recurred during the 6-month follow-up. Lessons: VSD could be a reliable treatment

  13. Development and Optimization of Gas-Assisted Gravity Drainage (GAGD) Process for Improved Light Oil Recovery

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Dandina N. Rao; Subhash C. Ayirala; Madhav M. Kulkarni

    This is the final report describing the evolution of the project ''Development and Optimization of Gas-Assisted Gravity Drainage (GAGD) Process for Improved Light Oil Recovery'' from its conceptual stage in 2002 to the field implementation of the developed technology in 2006. This comprehensive report includes all the experimental research, models developments, analyses of results, salient conclusions and the technology transfer efforts. As planned in the original proposal, the project has been conducted in three separate and concurrent tasks: Task 1 involved a physical model study of the new GAGD process, Task 2 was aimed at further developing the vanishing interfacialmore » tension (VIT) technique for gas-oil miscibility determination, and Task 3 was directed at determining multiphase gas-oil drainage and displacement characteristics in reservoir rocks at realistic pressures and temperatures. The project started with the task of recruiting well-qualified graduate research assistants. After collecting and reviewing the literature on different aspects of the project such gas injection EOR, gravity drainage, miscibility characterization, and gas-oil displacement characteristics in porous media, research plans were developed for the experimental work to be conducted under each of the three tasks. Based on the literature review and dimensional analysis, preliminary criteria were developed for the design of the partially-scaled physical model. Additionally, the need for a separate transparent model for visual observation and verification of the displacement and drainage behavior under gas-assisted gravity drainage was identified. Various materials and methods (ceramic porous material, Stucco, Portland cement, sintered glass beads) were attempted in order to fabricate a satisfactory visual model. In addition to proving the effectiveness of the GAGD process (through measured oil recoveries in the range of 65 to 87% IOIP), the visual models demonstrated three possible

  14. Vacuum-assisted fluid flow in microchannels to pattern substrates and cells.

    PubMed

    Shrirao, Anil B; Kung, Frank H; Yip, Derek; Cho, Cheul H; Townes-Anderson, Ellen

    2014-09-01

    Substrate and cell patterning are widely used techniques in cell biology to study cell-to-cell and cell-substrate interactions. Conventional patterning techniques work well only with simple shapes, small areas and selected bio-materials. This paper describes a method to distribute cell suspensions as well as substrate solutions into complex, long, closed (dead-end) polydimethylsiloxane (PDMS) microchannels using negative pressure. Our method builds upon a previous vacuum-assisted method used for micromolding (Jeon et al 1999 Adv. Mater 11 946) and successfully patterned collagen-I, fibronectin and Sal-1 substrates on glass and polystyrene surfaces, filling microchannels with lengths up to 120 mm and covering areas up to 13 × 10 mm(2). Vacuum-patterned substrates were subsequently used to culture mammalian PC12 and fibroblast cells and amphibian neurons. Cells were also patterned directly by injecting cell suspensions into microchannels using vacuum. Fibroblast and neuronal cells patterned using vacuum showed normal growth and minimal cell death indicating no adverse effects of vacuum on cells. Our method fills reversibly sealed PDMS microchannels. This enables the user to remove the PDMS microchannel cast and access the patterned biomaterial or cells for further experimental purposes. Overall, this is a straightforward technique that has broad applicability for cell biology.

  15. Vacuum-assisted Fluid Flow in Microchannels to Pattern Substrates and Cells

    PubMed Central

    Shrirao, Anil B.; Kung, Frank H.; Yip, Derek; Cho, Cheul H.; Townes-Anderson, Ellen

    2014-01-01

    Substrate and cell patterning are widely used techniques in cell biology to study cell-to-cell and cell-to-substrate interactions. Conventional patterning techniques work well only with simple shapes, small areas and selected bio-materials. This paper describes a method to distribute cell suspensions as well as substrate solutions into complex, long, closed (dead-end) polydimethylsiloxane (PDMS) microchannels using negative pressure. Our method builds upon a previous vacuum-assisted method used for micromolding (Jeon, Choi et al. 1999) and successfully patterned collagen-I, fibronectin and Sal-1 substrates on glass and polystyrene surfaces, filling microchannels with lengths up to 120 mm and covering areas up to 13 × 10 mm2. Vacuum-patterned substrates were subsequently used to culture mammalian PC12 and fibroblast cells and amphibian neurons. Cells were also patterned directly by injecting cell suspensions into microchannels using vacuum. Fibroblast and neuronal cells patterned using vacuum showed normal growth and minimal cell death indicating no adverse effects of vacuum on cells. Our method fills reversibly sealed PDMS microchannels. This enables the user to remove the PDMS microchannel cast and access the patterned biomaterial or cells for further experimental purposes. Overall, this is a straightforward technique that has broad applicability for cell biology. PMID:24989641

  16. Vacuum-Assisted, Constant-Force Exercise Device

    NASA Technical Reports Server (NTRS)

    Hansen, Christopher P.; Jensen, Scott

    2006-01-01

    The vacuum-assisted, constant-force exercise device (VAC-FED) has been proposed to fill a need for a safe, reliable exercise machine that would provide constant loads that could range from 20 to 250 lb (0.09 to 1.12 kN) with strokes that could range from 6 to 36 in. (0.15 to 0.91 m). The VAC-FED was originally intended to enable astronauts in microgravity to simulate the lifting of free weights, but it could just as well be used on Earth for simulated weight lifting and other constant-force exercises. Because the VAC-FED would utilize atmospheric/vacuum differential pressure instead of weights to generate force, it could weigh considerably less than either a set of free weights or a typical conventional exercise machine based on weights. Also, the use of atmospheric/ vacuum differential pressure to generate force would render the VAC-FED inherently safer, relative to free weights and to conventional exercise machines that utilize springs to generate forces. The overall function of the VAC-FED would be to generate a constant tensile force in an output cable, which would be attached to a bar, handle, or other exercise interface. The primary force generator in the VAC-FED would be a piston in a cylinder. The piston would separate a volume vented to atmosphere at one end of the cylinder from an evacuated volume at the other end of the cylinder (see figure). Hence, neglecting friction at the piston seals, the force generated would be nearly constant equal to the area of the piston multiplied by the atmospheric/vacuum differential pressure. In the vented volume in the cylinder, a direct-force cable would be looped around a pulley on the piston, doubling the stroke and halving the tension. One end of the direct-force cable would be anchored to a cylinder cap; the other end of the direct-force cable would be wrapped around a variable-ratio pulley that would couple tension to the output cable. As its name suggests, the variable-ratio pulley would contain a mechanism that

  17. Development of Sub-Ischial Prosthetic Sockets with Vacuum-Assisted Suspension for Highly Active Persons with Transfemoral Amputations

    DTIC Science & Technology

    2013-10-01

    15. SUBJECT TERMS Transfemoral amputation, sub-ischial socket, prosthesis , vacuum-assisted suspension 16. SECURITY CLASSIFICATION OF: 17...vacuum for suspension of the prosthesis ...14 Task 6 Determine range of volumes to be evacuated from transfemoral sockets of highly active prosthesis users

  18. Dural arteriovenous fistulas as a cause of intracranial hypertension due to impairment of cranial venous outflow

    PubMed Central

    Cognard, C.; Casasco, A.; Toevi, M.; Houdart, E.; Chiras, J.; Merland, J.

    1998-01-01

    OBJECTIVES—A retrospective study was carried out on 13 patients with intracranial dural arteriovenous fistulas (DAVFs) who presented with isolated or associated signs of intracranial hypertension.
METHODS—Nine patients presented with symptoms of intracranial hypertension at the time of diagnosis. Ocular fundoscopy available in 12 patients showed bilateral papilloedema in eight and optic disk atrophy in four. Clinical evolution was particularly noticeable in five patients because of chronic (two patients) or acute (after lumbar shunting or puncture: three patients, one death) tonsillar herniation.
RESULTS—Two patients had a type I fistula (drainage into a sinus, with a normal antegrade flow direction). The remaining 11 had type II fistulas (drainage into a sinus, with abnormal retrograde venous drainage into sinuses or cortical veins). Stenosis or thrombosis of the sinus(es) distal to the fistula was present in five patients. The cerebral venous drainage was abnormal in all patients.
CONCLUSION—Type II (and some type I) DAVFs may present as isolated intracranial hypertension mimicking benign intracranial hypertension. Normal cerebral angiography should be added as a fifth criterion of benign intracranial hypertension. The cerebral venous drainage pattern must be carefully studied by contralateral carotid and vertebral artery injections to correctly evaluate the impairment of the cerebral venous outflow. Lumbar CSF diversion (puncture or shunting) may induce acute tonsillar herniation and should be avoided absolutely. DAVF may induce intracranial hypertension, which has a poor long term prognosis and may lead to an important loss of visual acuity and chronic tonsillar herniation. Consequently, patients with intracranial hypertension must be treated, even agressively, to obliterate the fistula or at least to reduce the arterial flow and to restore a normal cerebral venous drainage. The endovascular treatment may associate arterial or transvenous

  19. The Essentials of Parathyroid Hormone Venous Sampling

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Taslakian, Bedros, E-mail: btaslakian@gmail.com; Trerotola, Scott O., E-mail: streroto@uphs.upenn.edu; Sacks, Barry, E-mail: bsacks@bidmc.harvard.edu

    Hyperparathyroidism is an excess of parathyroid hormone in the blood due to over-activity of one or more parathyroid gland. Localization of abnormal glands with noninvasive imaging modalities, such as technetium sestamibi scan and cross-sectional imaging, has a high success rate. Parathyroid venous sampling is performed for patients with persistent or recurrent disease after previous parathyroid surgery, when repeat noninvasive imaging studies are negative or discordant. The success of invasive localization studies and results interpretation is dependent on the interventional radiologist’s understanding of the normal and ectopic anatomic locations of parathyroid glands, as well as their blood supply and venous drainage.more » Anatomic and technical considerations for selective parathyroid venous sampling are reviewed.« less

  20. The benefits of using a vacuum-assisted socket system to improve balance and gait in elderly transtibial amputees.

    PubMed

    Samitier, C Beatriz; Guirao, Lluis; Costea, Maria; Camós, Josep M; Pleguezuelos, Eulogio

    2016-02-01

    Lower limb amputation leads to impaired balance, ambulation, and transfers. Proper fit of the prosthesis is a determining factor for successful ambulation. Vacuum-assisted socket systems extract air from the socket, which decreases pistoning and probability of soft-tissue injuries and increases proprioception and socket comfort. To investigate the effect of vacuum-assisted socket system on transtibial amputees' performance-based and perceived balance, transfers, and gait. Quasi-experimental before-and-after study. Subjects were initially assessed using their prosthesis with the regular socket and re-evaluated 4 weeks after fitting including the vacuum-assisted socket system. We evaluated the mobility grade using Medicare Functional Classification Level, Berg Balance Scale, Four Square Step Test, Timed Up and Go Test, the 6-Min Walk Test, the Locomotor Capabilities Index, Satisfaction with Prosthesis (SAT-PRO questionnaire), and Houghton Scale. A total of 16 unilateral transtibial dysvascular amputees, mean age 65.12 (standard deviation = 10.15) years. Using the vacuum-assisted socket system, the patients significantly improved in balance, gait, and transfers: scores of the Berg Balance Scale increased from 45.75 (standard deviation = 6.91) to 49.06 (standard deviation = 5.62) (p < 0.01), Four Square Step Test decreased from 18.18 (standard deviation = 3.84) s to 14.97 (3.9) s (p < 0.01), Timed Up and Go Test decreased from 14.3 (standard deviation = 3.29) s to 11.56 (2.46) s (p < 0.01). The distance walked in the 6-Min Walk Test increased from 288.53 (standard deviation = 59.57) m to 321.38 (standard deviation = 72.81) m (p < 0.01). Vacuum-assisted socket systems are useful for improving balance, gait, and transfers in over-50-year-old dysvascular transtibial amputees. This study gives more insight into the use of vacuum-assisted socket systems to improve elderly transtibial dysvascular amputees

  1. Integrated cooling-vacuum-assisted 1540-nm erbium:glass laser is effective in treating mild-to-moderate acne vulgaris.

    PubMed

    Politi, Y; Levi, A; Enk, C D; Lapidoth, M

    2015-12-01

    Acne treatment by a mid-infrared laser may be unsatisfactory due to deeply situated acne-affected sebaceous glands which serve as its target. Skin manipulation by vacuum and contact cooling may improve laser-skin interaction, reduce pain sensation, and increase overall safety and efficacy. To evaluate the safety and efficacy of acne treatment using an integrated cooling-vacuum-assisted 1540-nm erbium:glass laser, a prospective interventional study was conducted. It included 12 patients (seven men and five women) suffering from mild-to-moderate acne vulgaris. The device utilizes a mid-infrared 1540-nm laser (Alma Lasers Ltd. Caesarea, Israel), which is integrated with combined cooling-vacuum-assisted technology. An acne lesion is initially manipulated upon contact by a vacuum-cooling-assisted tip, followed by three to four stacked laser pulses (500-600 mJ, 4 mm spot size, and frequency of 2 Hz). Patients underwent four to six treatment sessions with a 2-week interval and were followed-up 1 and 3 months after the last treatment. Clinical photographs were taken by high-resolution digital camera before and after treatment. Clinical evaluation was performed by two independent dermatologists, and results were graded on a scale of 0 (exacerbation) to 4 (76-100 % improvement). Patients' and physicians' satisfaction was also recorded. Pain perception and adverse effects were evaluated as well. All patients demonstrated a moderate to significant improvement (average score of 3.6 and 2.0 within 1 and 3 months, respectively, following last treatment session). No side effects, besides a transient erythema, were observed. Cooling-vacuum-assisted 1540-nm laser is safe and effective for the treatment of acne vulgaris.

  2. Deep venous thrombosis and postthrombotic syndrome: invasive management.

    PubMed

    Comerota, A J

    2015-03-01

    Invasive management of postthrombotic syndrome encompasses the two ends of the deep vein thrombosis spectrum, patients with acute iliofemoral deep vein thrombosis and those with chronic postthrombotic iliofemoral venous obstruction. Of all patients with acute deep vein thrombosis, those with involvement of the iliofemoral segments have the most severe chronic postthrombotic morbidity. Catheter-based techniques now permit percutaneous treatment to eliminate thrombus, restore patency, potentially maintain valvular function, and improve quality of life. Randomized trial data support an initial treatment strategy of thrombus removal. Failure to eliminate acute thrombus from the iliofemoral system leads to chronic postthrombotic obstruction of venous outflow. Debilitating chronic postthrombotic symptoms of the long-standing obstruction of venous outflow can be reduced by restoring unobstructed venous drainage from the profunda femoris vein to the vena cava. © The Author(s) 2015 Reprints and permissions: sagepub.co.uk/journalsPermissions.nav.

  3. Influence of manual lymphatic drainage on health-related quality of life and symptoms of chronic venous insufficiency: a randomized controlled trial.

    PubMed

    dos Santos Crisóstomo, Rute Sofia; Costa, Daniela Sofia Albino; de Luz Belo Martins, Catarina; Fernandes, Tânia Isabel Russo; Armada-da-Silva, Paulo A

    2015-02-01

    To evaluate the efficacy of manual lymphatic drainage (MLD) in improving health-related quality of life (HRQOL), symptomatology, and physical status in patients with chronic venous insufficiency (CVI). Single-blind randomized controlled trial. Health community attendant service. Subjects with CVI (N=41) were randomly assigned to an experimental group (n=20; mean age, 54.6±11.3y) or control group (n=21; mean age, 46.8±11.1y). The experimental group completed 10 lower extremity MLD sessions over 4 weeks and 1 educational session. The control group only attended the educational session. Outcome measures were taken at baseline (t0), at the end of 4 weeks (t1), and after 2 months for follow-up (t2). HRQOL was assessed with the Chronic Venous Insufficiency Quality of Life Questionnaire-20, symptoms (fatigue, heaviness) were assessed with a visual analog scale, severity of the disease was assessed with the Venous Clinical Severity Score (VCSS) (total score, score for each item), leg volumetry was assessed with perimeters, and plantar/dorsiflexion strength and ankle range of motion (ROM) were assessed with dynamometry. A significant interaction group×time effect was found for pain on HRQOL (F2,78=3.507; P=.035; partial η2=.087), clinical severity (F2,78=5.231; P=.007; partial η2=.118), especially for venous edema (assessed with the VCSS), fatigue (F1.67,65.21=4.690; P=.012; partial η2=.107), and heaviness (F1.57,61.32=9.702; P=.001; partial η2=.199), with the experimental group improving from t0 to t1 and t0 to t2 in all of these outcomes. No effect of MLD treatment could be found for ankle muscle strength, ankle ROM, and leg volume. Short-term MLD treatment ameliorates CVI severity and related edema, symptoms, and pain HRQOL in patients with CVI. Copyright © 2015 American Congress of Rehabilitation Medicine. Published by Elsevier Inc. All rights reserved.

  4. Occiput posterior fetal head position increases the risk of anal sphincter injury in vacuum-assisted deliveries.

    PubMed

    Wu, Jennifer M; Williams, Kathryn S; Hundley, Andrew F; Connolly, AnnaMarie; Visco, Anthony G

    2005-08-01

    The purpose of this study was to determine whether an occiput posterior (OP) fetal head position increases the risk for anal sphincter injury when compared with an occiput anterior (OA) position in vacuum-assisted deliveries. We conducted a retrospective cohort study of 393 vacuum-assisted singleton vaginal deliveries. Maternal demographics and obstetric and neonatal data were collected from an obstetric database and chart review. Within the OP group, 41.7% developed a third- or fourth-degree laceration compared with 22.0% in the OA group (OR 2.5, 95% CI 1.4-4.7). In a logistic regression model that controlled for BMI, race, nulliparity, length of second stage, episiotomy, birth weight, head circumference, and fetal head position, OP position was 4.0 times (95% CI 1.7-9.6) more likely to be associated with an anal sphincter injury than OA position. Among vacuum deliveries, an OP head position confers an incrementally increased risk for anal sphincter injury over an OA position.

  5. The Portal Theory Supported by Venous Drainage–Selective Fat Transplantation

    PubMed Central

    Rytka, Julia M.; Wueest, Stephan; Schoenle, Eugen J.; Konrad, Daniel

    2011-01-01

    OBJECTIVE The “portal hypothesis” proposes that the liver is directly exposed to free fatty acids and cytokines increasingly released from visceral fat tissue into the portal vein of obese subjects, thus rendering visceral fat accumulation particularly hazardous for the development of hepatic insulin resistance and type 2 diabetes. In the present study, we used a fat transplantation paradigm to (artificially) increase intra-abdominal fat mass to test the hypothesis that venous drainage of fat tissue determines its impact on glucose homeostasis. RESEARCH DESIGN AND METHODS Epididymal fat pads of C57Bl6/J donor mice were transplanted into littermates, either to the parietal peritoneum (caval/systemic venous drainage) or, by using a novel approach, to the mesenterium, which confers portal venous drainage. RESULTS Only mice receiving the portal drained fat transplant developed impaired glucose tolerance and hepatic insulin resistance. mRNA expression of proinflammatory cytokines was increased in both portally and systemically transplanted fat pads. However, portal vein (but not systemic) plasma levels of interleukin (IL)-6 were elevated only in mice receiving a portal fat transplant. Intriguingly, mice receiving portal drained transplants from IL-6 knockout mice showed normal glucose tolerance. CONCLUSIONS These results demonstrate that the metabolic fate of intra-abdominal fat tissue transplantation is determined by the delivery of inflammatory cytokines to the liver specifically via the portal system, providing direct evidence in support of the portal hypothesis. PMID:20956499

  6. Longitudinal Volume Quantification of Deep Medullary Veins in Patients with Cerebral Venous Sinus Thrombosis : Venous Volume Assessment in Cerebral Venous Sinus Thrombosis Using SWI.

    PubMed

    Dempfle, A K; Harloff, A; Schuchardt, F; Bäuerle, J; Yang, S; Urbach, H; Egger, K

    2017-06-06

    Susceptibility-weighted imaging (SWI) visualizes small cerebral veins with high sensitivity and could, thus, enable quantification of hemodynamics of deep medullary veins. We aimed to evaluate volume changes of deep medullary veins in patients with acute cerebral venous sinus thrombosis (CVST) over time in comparison to healthy controls. All magnetic resonance imaging (MRI) experiments were executed at 3 T using a 32-channel head coil. Based on SWI and semiautomatic postprocessing (statistical parametric mapping [SPM8] and ANTs), the volume of deep medullary veins was quantified in 14 patients with acute CVST at baseline and the 6‑month follow-up, as well as in 13 healthy controls undergoing repeated MRI examination with an interscan interval of at least 1 month. Deep medullary venous volume change over time was significantly different between healthy controls and patient groups (p < 0.001). Patients with superior sagittal sinus thrombosis (SSST) showed a significant decline from baseline to follow-up measurements (9.8 ± 4.9 ml versus 7.5 ± 4.2 ml; p = 0.02), whereas in patients with transverse sinus thrombosis (TST) and healthy controls no significant volume changes were observable. Venous volume quantification was feasible and reproducible both in healthy volunteers and in patients. The decrease of venous volume in patients over time represents improvement of venous drainage, reduction of congestion, and normalization of microcirculation due to treatment. Thus, quantification of venous microcirculation could be valuable for estimation of prognosis and guidance of CVST therapy in the future.

  7. Flat epithelial atypia in directional vacuum-assisted biopsy of breast microcalcifications: surgical excision may not be necessary.

    PubMed

    McCroskey, Zulfia; Sneige, Nour; Herman, Carolyn R; Miller, Ross A; Venta, Luz A; Ro, Jae Y; Schwartz, Mary R; Ayala, Alberto G

    2018-02-21

    The aim of this study was to analyze the clinicopathological features of patients with flat epithelial atypia, diagnosed in directional vacuum-assisted biopsy targeting microcalcifications, to identify upgrade rate to in situ ductal or invasive breast carcinoma, and determine factors predicting carcinoma in the subsequent excision. We retrospectively evaluated the histological, clinical, and mammographic features of 69 cases from 65 women, with directional vacuum-assisted biopsy-diagnosed flat epithelial atypia with or without atypical ductal hyperplasia or atypical lobular hyperplasia, which underwent subsequent surgical excision. The extent and percentage of microcalcifications sampled by directional vacuum-assisted biopsy were evaluated by mammography. All biopsy and surgical excision slides were reviewed. The age of the women ranged from 40 to 85 years (mean 57 years). All patients presented with mammographically detected microcalcifications only, except in one case that had associated architectural distortion. Extent of calcifications ranged from <1 cm (n = 47), 1-3 cm (n = 15) to > 3 cm (n = 6), and no measurement (n = 1). A mean of 11 cores (range 6-25) was obtained from each lesion. Post-biopsy mammogram revealed >90% removal of calcifications in 81% of cases. Pure flat epithelial atypia represented nearly two-thirds of directional vacuum-assisted biopsy specimens (n = 43, 62%), while flat epithelial atypia coexisted with atypical ductal hyperplasia (18 cases, 26%), or atypical lobular hyperplasia (8 cases, 12%). Upon excision, none of the cases were upgraded to in situ ductal or invasive breast cancer. In one case, however, an incidental, tubular carcinoma (4 mm) was found away from biopsy site. Excluding this case, the upgrade rate was 0%. Our study adds to the growing evidence that diagnosis of flat epithelial atypia on directional vacuum-assisted biopsy for microcalcifications as the only imaging finding is not associated

  8. Ultrasound-Guided Core-Needle Versus Vacuum-Assisted Breast Biopsy: A Cost Analysis Based on the American Society of Breast Surgeons' Mastery of Breast Surgery Registry.

    PubMed

    Grady, Ian; Vasquez, Tony; Tawfik, Sara; Grady, Sean

    2017-03-01

    To evaluate the cost-efficacy of vacuum-assisted ultrasound-guided breast biopsy instruments compared to ultrasound-guided 14-gauge spring-loaded core-needle biopsy. The American Society of Breast Surgeons' Mastery of Breast Surgery Registry was reviewed. Biopsy findings, any rebiopsy, and the instrument used were abstracted for 31,451 ultrasound-guided biopsy procedures performed between 2001 and July 2014. Rates of cancer diagnosis and rebiopsy were calculated for each instrument. A linear mathematical model was developed to calculate total cost per cancer diagnosis, including procedural costs and the costs of any additional surgical rebiopsy procedures. Mean cost per cancer diagnosis with confidence limits was then determined for 14-gauge spring-loaded core-needle biopsy and 14 different vacuum-assisted instruments. For 14-gauge spring-loaded core-needle biopsy, mean cost per cancer diagnosis was $4346 (4327-$4366). For the vacuum-assisted instruments, mean cost per cancer diagnosis ranged from a low of $3742 ($3732-$3752) to a high of $4779 ($4750-$4809). Vacuum-assisted instruments overall were more cost-effective than core with a mean cost per cancer diagnosis of $4052 ($4038-$4067) (p < 0.05). Tethered vacuum-assisted instruments performed best with a mean cost per cancer diagnosis of $3978 ($3964-$3991) (p < 0.05). Nontethered devices had a mean cost per cancer diagnosis of $4369 ($4350-$4388), a result no better than core (p < 0.05). Ultrasound-guided vacuum-assisted breast biopsy had a lower mean cost per cancer diagnosis than 14-gauge spring-loaded core-needle biopsy. This advantage was only seen in tethered vacuum-assisted instruments. Within device families, larger instruments tended to outperform smaller instruments.

  9. Venous pooling and drainage affects photoplethysmographic signals at different vertical hand positions

    NASA Astrophysics Data System (ADS)

    Hickey, Michelle; Phillips, Justin P.; Kyriacou, Panayiotis

    2015-03-01

    The aim of the current work is to investigate the possibility of augmenting pulse oximetry algorithms to enable the estimation of venous parameters in peripheral tissues. In order to further understand the contribution of venous blood to the photoplethysmographic (PPG) signal, recordings were made from six healthy volunteer subjects during an exercise in which the right hand was placed in various positions above and below heart level. The left hand was kept at heart level as a control while the right hand was moved. A custom-made two-channel dual wavelength PPG instrumentation system was used to obtain the red and infrared plethysmographic signals from both the right and left index fingers simultaneously using identical sensors. Laser Doppler flowmetry signals were also recorded from an adjacent fingertip on the right hand. Analysis of all acquired PPG signals indicated changes in both ac and dc amplitude of the right hand when the position was changed, while those obtained from the left (control) hand remained relatively constant. Most clearly, in the change from heart level to 50cm below heart level there is a substantial decrease in both dc and ac amplitudes. This decrease in dc amplitude most likely corresponds to increased venous pooling, and hence increased absorption of light. It is speculated that the decrease in ac PPG amplitude is due to reduced arterial emptying during diastole due to increased downstream resistance due to venous pooling.

  10. Surface oxidation of GaN(0001): Nitrogen plasma-assisted cleaning for ultrahigh vacuum applications

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Gangopadhyay, Subhashis; Schmidt, Thomas, E-mail: tschmidt@ifp.uni-bremen.de; Kruse, Carsten

    The cleaning of metal-organic vapor-phase epitaxial GaN(0001) template layers grown on sapphire has been investigated. Different procedures, performed under ultrahigh vacuum conditions, including degassing and exposure to active nitrogen from a radio frequency nitrogen plasma source have been compared. For this purpose, x-ray photoelectron spectroscopy, reflection high-energy electron diffraction, and scanning tunneling microscopy have been employed in order to assess chemical as well as structural and morphological surface properties. Initial degassing at 600 °C under ultrahigh vacuum conditions only partially eliminates the surface contaminants. In contrast to plasma assisted nitrogen cleaning at temperatures as low as 300 °C, active-nitrogen exposure at temperaturesmore » as high as 700 °C removes the majority of oxide species from the surface. However, extended high-temperature active-nitrogen cleaning leads to severe surface roughening. Optimum results regarding both the removal of surface oxides as well as the surface structural and morphological quality have been achieved for a combination of initial low-temperature plasma-assisted cleaning, followed by a rapid nitrogen plasma-assisted cleaning at high temperature.« less

  11. Arterial supply and venous drainage of the choroid plexus of the human lateral ventricle in the prenatal period as revealed by vascular corrosion casts and SEM.

    PubMed

    Zagórska-Swiezy, K; Litwin, J A; Gorczyca, J; Pityński, K; Miodoński, A J

    2008-08-01

    The topography of the arterial supply and venous drainage was visualised by corrosion casting and scanning electron microscopy in the human foetal (20 weeks) choroid plexus of the lateral ventricle. Although secondary villi were not yet present at that developmental stage, the topography of the large arteries and veins almost fully corresponded to that described in adult individuals. The only major difference observed was a lack of the typical tortuosity of the lateral branch of the anterior choroidal artery and of the superior choroidal vein, which probably develops during further expansion of the vascular system associated with the formation of secondary villi.

  12. Initial Australasian experience with portal-enteric drainage in simultaneous pancreas-kidney transplantation.

    PubMed

    Kave, Ben; Yii, Ming; Bell, Roger; Kanellis, John; Scott, David; Saunder, Alan

    2010-10-01

    Pancreas-kidney transplantation is currently the most effective method to re-establish euglycaemia in insulin-dependent diabetics with associated renal failure. The standard technique employed has been bladder drainage of exocrine secretions coupled with systemic venous drainage ('systemic-bladder' (SB) drainage). The more physiological technique, enteric exocrine with portal venous drainage ('portal-enteric' (PE) drainage), has been utilized sparingly in the past as a result of fears of technical complications. This paper compares the Monash Medical Centre experience with both techniques. A total of 68 simultaneous pancreas-kidney transplantations were performed at Monash Medical Centre from 1991 until 2004. The first 37 received SB drainage. Since March 2001, 27 have received PE drainage. This retrospective study compared the SB group (n= 37) with the PE group (n= 27), with a 2-year follow-up, examining a number of surgical outcomes. Two-year patient (94.3 versus 96.0%), kidney (89.2 versus 85.2%), pancreas (77.9 versus 71.4%) and event-free (73.0 versus 67.7%) survivals were all similar between the SB and PE groups, respectively. Although surgery took longer in PE subjects (4 h : 47 min ± 0:48 versus 5 h : 16 min ± 1:00; P= 0.045), less intraoperative transfusions were required (1.3 ± 1.43 versus 0.52 ± 0.90; P= 0.024). Length of hospital stay and time to insulin independence were similar. Pancreas graft thrombosis rates were similar (10.8% SB versus 7.4% PE, P= 0.497). PE drainage is a safe and viable method for pancreas transplantation, which can be performed with excellent outcomes. An increased rate of complications with PE drainage has not been demonstrated in this series. © 2009 The Authors. ANZ Journal of Surgery © 2009 Royal Australasian College of Surgeons.

  13. Successful transcatheter occlusion of an anomalous pulmonary vein with dual drainage to the left atrium.

    PubMed

    Wilson, W; Horlick, E; Benson, L

    2015-06-01

    We describe a case of a scimitar syndrome "variant" where dual drainage existed from the right upper and middle pulmonary veins to the inferior vena cava and left atrium. Device closure of the anomalous vein at the level of the connection to the IVC was successful in achieving diversion of pulmonary venous flow to the left atrium. Vigilance during work-up of anomalous pulmonary venous drainage (whether isolated or associated with other cardiac defects that may be amenable to device closure) is important to define the presence of dual connections to the left atrium, in which case a less-invasive transcatheter approach may be feasible. © 2015 Wiley Periodicals, Inc.

  14. Vacuum-assisted closure as a surgical assistant in life-threatening necrotizing fasciitis in children

    PubMed Central

    Al-Subhi, FS; Zuker, RM; Cole, WG

    2010-01-01

    Necrotizing fasciitis is a severe soft tissue infection that can involve skin, subcutaneous fat, fascia and muscle. It can result in devastating sequelae including tissue necrosis, sepsis, toxic shock syndrome, cardiopulmonary collapse and death. To control rapidly spreading necrosis, early diagnosis and aggressive surgical treatment with extensive radical debridement of the affected areas is necessary, as well as systemic administration of broad-spectrum antimicrobials and, very often, intensive care support. The subatmospheric negative pressure dressing has been previously used in acute and complex wounds management. The concept of using vacuum-assisted closure dressing as another management component is presented in the current article. PMID:22131841

  15. Skin graft secured by VAC (vacuum-assisted closure) therapy in chronic leg ulcers: A controlled randomized study.

    PubMed

    Leclercq, A; Labeille, B; Perrot, J-L; Vercherin, P; Cambazard, F

    2016-01-01

    Leg ulcers are a common condition. There have been very few studies of combined therapy involving VAC (vacuum-assisted closure) and skin graft. We performed a randomized controlled trial of VAC therapy vs. hydrocolloid dressings over 5 days following autologous grafting on chronic leg ulcers. The primary objective was to assess the difference in success (defined as a reduction in wound area of at least 50% at 1 month) between the two dressing methods. Forty-six patients with ulcers present for over one month were included. Following a 7-day hospitalization period, follow-up was performed for 3 months on an outpatient basis. Our study does not demonstrate a statistically significant difference, with a 45.8% success rate in the VAC group vs. 40.9% in the conventional dressing group (P=0.73). In the venous ulcer group, the success rate was 57.9% for VAC vs. 40% for conventional dressings (P=0.3). The difference in favor of VAC in this group was not statistically significant, most likely due to an insufficient number of patients studied. Our study does not demonstrate superiority of VAC associated with skin graft over conventional dressings. We observed more complications with VAC (40%) than with conventional dressings (23%) (P=0.06). Copyright © 2015 Elsevier Masson SAS. All rights reserved.

  16. Vacuum Flushing of Sewer Solids

    EPA Science Inventory

    The vacuum sewer and tank cleaning (flushing) technology removes sewer solids from urban drainage systems, such as storage tanks and pipes. This technology is both effective and inexpensive. In addition, it can be considered a true green technology. It operates under atmospheri...

  17. Drainage of malignant ascites: patient selection and perspectives

    PubMed Central

    Stukan, Maciej

    2017-01-01

    Malignant ascites (MA) is a sign of advanced cancer and poor prognosis. MA can result in impairment in quality of life (QOL) and significant symptoms. As a supportive treatment, ascites can be drained by paracentesis (PC), percutaneously implanted catheters (tunneled, untunneled, central venous catheters), or peritoneal ports, or peritoneovenous shunts. The aim of this study was to evaluate the effectiveness, safety, and patient-reported outcomes (PRO) of different drainage methods for the management of MA. A systematic review of the literature was performed, and 32 original articles met the inclusion criteria. Patients selected for permanent drain insertion demonstrated symptoms related to MA and had undergone repeated PC. The primary focus of the reviewed articles was procedural safety issues. The rate of technical success of drainage device installation was 100%. Most patients experienced improvements in symptom control after ascites drainage. When analyzed together, 19.7% (255/1297) of patients experienced any complication and 6.2% (81/1297) experienced serious adverse events during MA drainage. Complications were reported for every drainage method; however, the least occurred after PC or central venous catheter, while the most serious occurred after peritoneovenous shunts. Adverse events were as follows: catheter obstruction: 4.4%, infection: 4.1%, leakage: 3.5%, catheter dislodgment: 2.3%, hypotension: 0.6%, injuries during device insertion: 0.6%, renal impairment: 0.5%, electrolyte imbalance: 0.2%, other: 3.6%. PRO and QOL endpoints were available for 12 studies. When PRO were measured using an interview, a significant improvement in symptom control and QOL was reported in almost all patients. Once standardized questionnaires were used, improvements in symptomatic scores and role functioning were observed. Deterioration was observed in cognitive and emotional subscales. MA drainage is a safe and effective method to control symptoms associated with ascites

  18. Use of ultraportable vacuum therapy systems in the treatment of venous leg ulcer.

    PubMed

    Cuomo, Roberto; Nisi, Giuseppe; Grimaldi, Luca; Brandi, Cesare; D'Aniello, Carlo

    2017-10-23

    The high incidence of venous leg ulcers and the difficult to give a complete healing involves in an increase of costs for National Health System. Main therapies to obtain a fast healing are compressive bandages, treatment of abnormal venous flow and in-situ-strategies of wound care. Negative pressure therapy does not conventionally used, because these systems not allow the use of compression bandages. Recently the development of ultraportable devices has improved the compliance and the results. Ten patients with venous chronic ulcer on the lower extremities were recruited for this study: all patients had venous leg ulcers from at least one year. We treated the patients with autologous partial thickness skin graft and subsequently we applied NANOVA device included in compressive bandage. We used NANOVA for fourteen days and after we made traditional medications. We submitted a questionnaire to evaluate the impact of dressing and NANOVA device in the quality of life of patients. The device contributed to the formation of granulation tissue and increased the success rate of autologous skin graft without limiting mobility of patient. In addition to this, we have been able to perform compression bandages thanks to small size of this device. Eight ulcers healed within 90 days of medication. We believe that ultraportable negative pressure systems are useful devices for treatment of venous leg ulcers because them allows to realize a compressive bandage without mobility limitations.

  19. Prospective cohort study of a new vacuum delivery device to assist with complicated labour in low-resource settings.

    PubMed

    Khan, Mishal; Hashmani, Farah Naz; Ahmed, Sajjad; Ahmed, Owais; Asim, Shabnam S; Wajahat, Yasmin; Sobani, Shoaib; Syed, Shershah; Qazi, Fahad

    2015-02-01

    Currently available vacuum devices used to assist women undergoing complicated labour are unsuitable for use in low-resource settings. The objective of this study was to evaluate the safety and feasibility of a new low-cost vacuum device, named Koohi Goth Vacuum Delivery System (KGVDS), designed for use in low-resource settings. A hospital-based, multicentre, prospective cohort study with no control group was conducted in Karachi, Pakistan. After training, KGVDS devices were made available for use by labour room staff at their discretion when instrumental delivery was indicated. Women to whom KGVDS was applied were followed from the start of labour until discharge. Feasibility was assessed in terms of successful expulsion of the foetal head following application of KGVDS and ease of use ratings. Safety was assessed by observing maternal and newborn post-delivery outcomes prior to discharge. Koohi Goth Vacuum Delivery System was applied to 137 women requiring instrumental delivery, of whom 111 (81%; 95% CI = 74-88%) successfully expelled the foetal head assisted by KGVDS and 103 (75%) stated that they would agree to use KGVDS again. There were no serious maternal or neonatal injuries or infections related to KGVDS use. The mean score for 'ease of use' given by doctors and midwives using the device was 8 of 10. Koohi Goth Vacuum Delivery System was feasible and safe to use for assisting complicated deliveries in low-resource hospitals in this initial evaluation. Our results indicate that this new device may have the potential to improve birth outcomes in settings where most mortality occurs and that further evaluations should be conducted. © 2014 John Wiley & Sons Ltd.

  20. Exocrine drainage in vascularized pancreas transplantation in the new millennium

    PubMed Central

    El-Hennawy, Hany; Stratta, Robert J; Smith, Fowler

    2016-01-01

    The history of vascularized pancreas transplantation largely parallels developments in immunosuppression and technical refinements in transplant surgery. From the late-1980s to 1995, most pancreas transplants were whole organ pancreatic grafts with insulin delivery to the iliac vein and diversion of the pancreatic ductal secretions to the urinary bladder (systemic-bladder technique). The advent of bladder drainage revolutionized the safety and improved the success of pancreas transplantation. However, starting in 1995, a seismic change occurred from bladder to bowel exocrine drainage coincident with improvements in immunosuppression, preservation techniques, diagnostic monitoring, general medical care, and the success and frequency of enteric conversion. In the new millennium, pancreas transplants are performed predominantly as pancreatico-duodenal grafts with enteric diversion of the pancreatic ductal secretions coupled with iliac vein provision of insulin (systemic-enteric technique) although the systemic-bladder technique endures as a preferred alternative in selected cases. In the early 1990s, a novel technique of venous drainage into the superior mesenteric vein combined with bowel exocrine diversion (portal-enteric technique) was designed and subsequently refined over the next ≥ 20 years to re-create the natural physiology of the pancreas with first-pass hepatic processing of insulin. Enteric drainage usually refers to jejunal or ileal diversion of the exocrine secretions either with a primary enteric anastomosis or with an additional Roux limb. The portal-enteric technique has spawned a number of newer and revisited techniques of enteric exocrine drainage including duodenal or gastric diversion. Reports in the literature suggest no differences in pancreas transplant outcomes irrespective of type of either venous or exocrine diversion. The purpose of this review is to examine the literature on exocrine drainage in the new millennium (the purported

  1. Vacuum-assisted wound closure and mesh-mediated fascial traction for open abdomen therapy - a systematic review.

    PubMed

    Acosta, Stefan; Björck, Martin; Petersson, Ulf

    2017-01-01

    The aim of this paper was to review the literature on vacuum-assisted wound closure and mesh-mediated fascial traction (VAWCM) in open abdomen therapy. It was designed as systematic review of observational studies. A Pub Med, EMBASE and Cochrane search from 2007/01-2016/07 was performed combining the Medical Subject Headings "vacuum", "mesh-mediated fascial traction", "temporary abdominal closure", "delayed abdominal closure", "open abdomen", "abdominal compartment syndrome", "negative pressure wound therapy" or "vacuum assisted wound closure". Eleven original studies were found including patients numbering from 7 to 111. Six studies were prospective and five were retrospective. Nine studies were on mixed surgical (n = 9), vascular (n = 6) and trauma (n = 6) patients, while two were exclusively on vascular patients. The primary fascial closure rate per protocol varied from 80-100%. The time to closure of the open abdomen varied between 9-32 days. The entero-atmospheric fistula rate varied from 0-10.0%. The in-hospital survival rate varied from 57-100%. In the largest prospective study, the incisional hernia rate among survivors at 63 months of median follow-up was 54% (27/50), and 16 (33%) repairs out of 48 incisional hernias were performed throughout the study period. The study patients reported lower short form health survey (SF-36) scores than the mean reference population, mainly dependent on the prevalence of major co-morbidities. There was no difference in SF-36 scores or a modified ventral hernia pain questionnaire (VHPQ) at 5 years of follow up between those with versus those without incisional hernias. A high primary fascial closure rate can be achieved with the vacuum-assisted wound closure and meshmediated fascial traction technique in elderly, mainly non-trauma patients, in need of prolonged open abdomen therapy.

  2. Papilloma diagnosed at MRI-guided vacuum-assisted breast biopsy: is surgical excision still warranted?

    PubMed

    Brennan, Sandra B; Corben, Adriana; Liberman, Laura; Dershaw, D David; Brogi, Edi; Van Zee, Kimberly J; Morris, Elizabeth

    2012-10-01

    The objective of our study was to determine the frequency of cancer at surgery in breast lesions yielding papilloma at MRI-guided 9-gauge vacuum-assisted biopsy (VAB) and to determine whether any features are associated with cancer upgrade. For this study, 1487 MRI-guided vacuum-assisted biopsies performed from January 2004 to March 2011 were reviewed. Lesions yielding papilloma were identified and classified as papilloma with or without atypia. Surgical findings were reviewed to determine the cancer rate. Statistical analysis was performed and 95% CIs were calculated. Papilloma was identified in 75 of the 1487 MRI-guided vacuum-assisted biopsies (5%). These 75 papillomas occurred in 73 women with a median age of 49 years (age range, 27-70 years). Of the 75 papillomas, 25 (33%) had atypia and 50 (67%) did not on core needle biopsy. Subsequent surgery of 67 of the 75 papillomas (89%) yielded ductal carcinoma in situ (DCIS) in four (6%; 95% CI, 2-15%). Surgery yielded DCIS in two of 23 papillomas with atypia (9%; 95% CI, 1-28%) at MRI-guided VAB and in two of 44 papillomas without atypia (5%; 95% CI, 0.4-16%) at MRI-guided VAB; these cancer rates did not differ significantly (p=0.6). Postmenopausal status (p=0.04) and histologic size of less than 0.2 cm (p=0.04) had a significant association with the cancer upgrade rate. Papilloma with or without atypia was found in 5% of patients who underwent MRI-guided VAB during the study period. Surgery revealed cancer in 6%. DCIS was found at surgery in 9% of lesions yielding papilloma with atypia versus 5% of lesions yielding papilloma without atypia. For lesions yielding papilloma with or without atypia at MRI-guided VAB, surgical excision is warranted.

  3. Matrix Assisted Ionization Vacuum (MAIV), a New Ionization Method for Biological Materials Analysis Using Mass Spectrometry*

    PubMed Central

    Inutan, Ellen D.; Trimpin, Sarah

    2013-01-01

    The introduction of electrospray ionization (ESI) and matrix-assisted laser desorption/ionization (MALDI) for the mass spectrometric analysis of peptides and proteins had a dramatic impact on biological science. We now report that a wide variety of compounds, including peptides, proteins, and protein complexes, are transported directly from a solid-state small molecule matrix to gas-phase ions when placed into the vacuum of a mass spectrometer without the use of high voltage, a laser, or added heat. This ionization process produces ions having charge states similar to ESI, making the method applicable for high performance mass spectrometers designed for atmospheric pressure ionization. We demonstrate highly sensitive ionization using intermediate pressure MALDI and modified ESI sources. This matrix and vacuum assisted soft ionization method is suitable for the direct surface analysis of biological materials, including tissue, via mass spectrometry. PMID:23242551

  4. The use of the venous stripper for graft removal in arterial reoperations.

    PubMed

    Shifrin, E G; Eid, A; Anner, H; Witz, M

    1987-10-01

    A simple technique for removal of synthetic grafts using a standard venous stripper inside the graft is described. The method permits the simultaneous placement of a drainage tube in the canal after graft removal in cases where the graft is infected.

  5. Vacuum Flushing of Sewer Solids (Slides)

    EPA Science Inventory

    The vacuum sewer and tank cleaning (flushing) technology removes sewer solids from urban drainage systems, such as storage tanks and pipes. This technology is both effective and inexpensive. In addition, it can be considered a true green technology. It operates under atmospheri...

  6. [Delayed (tension) pneumothorax after placement of a central venous catheter].

    PubMed

    Tan, E C; van der Vliet, J A

    1999-09-11

    Laborious attempts at introducing a central venous catheter for parenteral nutrition in two women, aged 36 and 62 years, were followed by shortness of breath after 32 and 10 hours, respectively. This symptom was due to a (tension) pneumothorax not visible on earlier roentgenograms. Thoracic drainage led to recovery. In all patients with a central venous catheter an undetected delayed pneumothorax can be present. Urgent chest X-ray examination should be performed in all patients with acute respiratory symptoms. Patients undergoing elective intubation with positive pressure breathing should be examined carefully, since they are at risk of developing a late (tension) pneumothorax.

  7. The relationship between perimesencephalic subarachnoid hemorrhage and deep venous system drainage pattern and calibrations.

    PubMed

    Buyukkaya, Ramazan; Yıldırım, Nalan; Cebeci, Hakan; Kocaeli, Hasan; Dusak, Abdürrahim; Ocakoğlu, Gökhan; Erdoğan, Cüneyt; Hakyemez, Bahattin

    2014-01-01

    The purpose of this study is to investigate the relationship between Rosenthal basal vein (BVR) type and diameter and perimesencephalic nonaneurysmal subarachnoid hemorrhage (P-SAH). Aneurysmal subarachnoid hemorrhage (A-SAH), P-SAH, and control groups were evaluated, and BVRs were classified by type. BVR diameters in patients were measured. There was a statistically significant difference of BVR drainage types between groups (P=.002). BVR diameters of patients with normal drainage pattern in P-SAH group were significantly smaller than those in both other groups (P<.001). There is a relationship between P-SAH and BVR primitive drainage type. P-SAH risk increases in parallel with decreasing caliber of BVR in patients with normal drainage pattern. Copyright © 2014 Elsevier Inc. All rights reserved.

  8. Bilateral anomalous drainage of the posterior divisions of renal veins into the azygos venous system in a 20-year-old woman: a case report.

    PubMed

    Pallangyo, Pedro; Lyimo, Frederick; Nicholaus, Paulina; Masatu, Stephano; Janabi, Mohamed

    2016-12-03

    Renal vein anomalies are relatively infrequent and generally asymptomatic. Preoperative knowledge of such variants is, however, of paramount importance in several angiographic and surgical procedures including renal venography, renal vein sampling, spermatic embolization, and renal transplantation. Inadequate knowledge and failure to recognize such anatomic variations may lead to several operative hazards including hemorrhage, nephrectomy, and even death. We report a case of bilateral anomalous drainage of the posterior divisions of renal veins into the azygos venous system in a 20-year-old woman of African descent from Tanzania who presented to us with a 12-year history of recurrent anemia. She had anemia, a positive sickling test, and hemoglobin electrophoresis revealed a sickle cell trait (AS). She underwent computed tomography angiography of her chest and abdomen to rule out the presence of arteriovenous malformations. Aortography findings were normal but venography results revealed features of tortuously dilated azygos and hemiazygos veins each receiving blood from its respective posterior division of renal vein. Although venous anomalies are relatively infrequent and generally lack a clinical significance, a thorough understanding of embryologic development and its associated errors is of immense importance in equipping angiographers and surgeons to select appropriate interventional/operative techniques, anticipate risks, and prevent intervention-related complications.

  9. Anomalous dual drainage of the right pulmonary veins in a patient with cor triatriatum: report of a case without scimitar sign.

    PubMed

    Tansel, T; Harmandar, B; Dayioglu, E; Onursal, E

    2006-02-01

    The majority of patients with partial anomalous drainage of pulmonary veins are asymptomatic during infancy and childhood. Patients with significant left-to-right shunt develop symptoms and benefit from early corrective surgery. Anomalous pulmonary veins draining into inferior vena cava is very rare and frequently encountered in association with scimitar syndrome. The purpose of this case report is to describe a non-scimitar patient with cor triatriatum who had anomalous dual drainage of right pulmonary veins into inferior vena cava/left atrium and anomalous connection of persistent left superior vena cava with a common pulmonary venous chamber. The patient underwent an operation with redirection of anomalous pulmonary venous drainage into left atrium and ligation of persistent left superior vena cava.

  10. [Sequelae of unilateral deep venous thrombosis in plethysmography of the calf].

    PubMed

    Zicot, M; Depairon, M

    1982-01-01

    Twenty four patients suffering from unilateral venous disturbances revealed by Doppler and secondary to a deep venous thrombosis were examined. The calf venous haemodynamics was analyzed by use of a strain-jauge plethysmograph. We determined the increase in venous volume due to the inflation of a thigh pneumatic cuff (pressure at 20, 40 and 60 mm Hg; delta V20, delta V40, delta V60). The maximal venous output (Vout) was measured after a quick release of the 60 mm Hg pressure. The maximal venous drainage (VMM) was assessed during a rhythmic exercise (tiptoeing) while standing; delta V20, delta V40 and delta V60 were nearly constantly reduced on the abnormal side (t of Student respectively 3.49; 6.09 and 5.07). Vout dropped proportionaly to delta V60. Some abnormalities due to valvular insufficiency were frequently present in the beginning of the inflation curve at the level of the abnormal limbs. VMM was nearly always largely decreased on the affected side (t = 5.43). The unilateral flow disturbances displayed by the Doppler were regularly going with abnormalities of the capacitive system, well demonstrated by comparison with the non-affected limbs.

  11. Post-Vacuum-Assisted Stereotactic Core Biopsy Clip Displacement: A Comparison Between Commercially Available Clips and Surgical Clip.

    PubMed

    Yen, Peggy; Dumas, Sandra; Albert, Arianne; Gordon, Paula

    2018-02-01

    The placement of localization clips following percutaneous biopsy is a standard practice for a variety of situations. Subsequent clip displacement creates challenges for imaging surveillance and surgical planning, and may cause confusion amongst radiologists and between surgeons and radiologists. Many causes have been attributed for this phenomenon including the commonly accepted "accordion effect." Herein, we investigate the performance of a low cost surgical clip system against 4 commercially available clips. We retrospectively reviewed 2112 patients who underwent stereotactic vacuum-assisted core biopsy followed by clip placement between January 2013 and June 2016. The primary performance parameter compared was displacement >10 mm following vacuum-assisted stereotactic core biopsy. Within the group of clips that had displaced, the magnitude of displacement was compared. There was a significant difference in displacement among the clip types (P < .0001) with significant pairwise comparisons between pediatric surgical clips and SecureMark (38% vs 28%; P = .001) and SenoMark (38% vs 27%; P = .0001) in the proportion displaced. The surgical clips showed a significant magnitude of displacement of approximately 25% greater average distance displaced. As a whole, the commercial clips performed better than the surgical clip after stereotactic vacuum-assisted core biopsy suggesting the surrounding outer component acts to anchor the central clip and minimizes clip displacement. The same should apply to tomosynthesis-guided biopsy. Crown Copyright © 2017. Published by Elsevier Inc. All rights reserved.

  12. Investigation of cerebral venous outflow in microgravity.

    PubMed

    Taibi, A; Gadda, G; Gambaccini, M; Menegatti, E; Sisini, F; Zamboni, P

    2017-10-31

    The gravitational gradient is the major component to face when considering the physiology of venous return, and there is a growing interest in understanding the mechanisms ensuring the heart filling, in the absence of gravity, for astronauts who perform long-term space missions. The purpose of the Drain Brain project was to monitor the cerebral venous outflow of a crew member during an experiment on the International Space Station (ISS), so as to study the compensatory mechanisms that facilitate this essential physiological action in subjects living in a microgravity environment. Such venous function has been characterized by means of a novel application of strain-gauge plethysmography which uses a capacitive sensor. In this contribution, preliminary results of our investigation have been presented. In particular, comparison of plethysmography data confirmed that long duration spaceflights lead to a redistribution of venous blood volume, and showed interesting differences in the amplitude of cardiac oscillations measured at the level of the neck veins. The success of the experiment has also demonstrated that thanks to its easy portability, non-invasiveness, and non-operator dependence, the proposed device can be considered as a novel tool for use aboard the ISS. Further trials are now under way to complete the investigation on the drainage function of the neck veins in microgravity.

  13. [Anastomotic leakage after laparoscopic-assisted radical right hemicolectomy: reason analysis and management].

    PubMed

    Wu, Xin; Lin, Guole; Qiu, Huizhong; Xiao, Yi; Wu, Bin

    2017-06-25

    To analyze the clinical features, possible reasons and management of anastomotic leakage after laparoscopic-assisted radical right hemicolectomy. Clinical data of 546 patients undergoing laparoscopic-assisted radical right hemicolectomy in Peking Union Medical College Hospital from October 2010 to September 2016 were retrospectively analyzed. The occurrence of anastomotic leakage and its countermeasures were evaluated. Among 546 patients, 8(1.5%) cases developed anastomotic leakage, including 7 males and 1 female with mean age of (54.3±10.3) years. Six cases of ascending colon cancer, 1 case of phlegmon and 1 case of arterior-venous malformation were confirmed after operation. The incidence of anastomotic leakage after D3 and D2 lymphadenectomy was 2.1%(6/290) and 0.8%(2/256). The time from operation to the diagnosis of anastomotic leakage was (6.6±3.6) days. The clinical manifestation of anastomotic leakage were stool-like drainage in 7 patients, fever in 4 and abdominal pain in 3. Amylase and bilirubin in drainage of 4 patients increased obviously. All the 8 patients underwent secondary ileostomy, including 4 with laparoscopy and 4 with laparotomy. One patient suffered from respiratory failure after re-operation because of severe abdominal infection and was cured by ventilator support treatment. Another one had pelvic encapsulated effusion and was treated by puncture drainage. All the patients discharged from hospital smoothly. Anastomotic leakage after laparoscopic-assisted right hemicolectomy is a quite rare but serious complication, which may be associated with over-cleaning of lymph fatty tissues. Ileostomy should be the first choice of anastomotic leakage after laparoscopy-assisted right hemicolectomy and its efficacy is satisfactory.

  14. Matrix Characterization and Development for the Vacuum Assisted Resin Transfer Molding Process

    NASA Technical Reports Server (NTRS)

    Grimsley, B. W.; Hubert, P.; Hou, T. H.; Cano, R. J.; Loos, A. C.; Pipes, R. B.

    2001-01-01

    The curing kinetics and viscosity of an epoxy resin system, SI-ZG-5A, have been characterized for application in the vacuum assisted resin transfer molding (VARTM) process. Impregnation of a typical carbon fiber perform provided the test bed for the characterization. Process simulations were carried out using the process model, COMPRO, to examine heat transfer and curing kinetics for a fully impregnated panel, neglecting resin flow. The predicted viscosity profile and final degree of cure were found to be in good agreement with experimental observations.

  15. Orbital venous malformation: percutaneous treatment using an electrolytically detachable fibred coil.

    PubMed

    Diolaiuti, Sara; Iizuka, Tateyuki; Schroth, Gerhard; Remonda, Luca; Laedrach, Kurt; El-Koussy, Marwan; Frueh, Beatrice E; Goldblum, David

    2009-03-01

    To report the efficacy of percutaneous treatment of an orbital venous malformation with an electrolytically detachable fibred coil. We report an instance of radiography-guided percutaneous treatment with an electrolytically detachable fibred coil in a 16-year-old boy with acute, spontaneous, painless proptosis on the left side, which progressed with time. Magnetic resonance imaging, angiography and orbitophlebography revealed a low-flow, intraorbital venous malformation. Percutaneous puncture and drainage were followed by a short remission. Following an acute recurrence, a single detachable fibred coil was deployed via a percutaneous approach under angiographic guidance. No radiological or clinical recurrences were observed over 4 years. Embolization of a deep orbital venous malformation with detachable fibred coils via a percutaneous approach can be highly effective, and may be considered before proceeding with open surgery.

  16. Ultrasound-assisted extraction coupled with under vacuum distillation of flavour compounds from spearmint (carvone-rich) plants: Comparison with conventional hydrodistillation.

    PubMed

    Da Porto, Carla; Decorti, Deborha

    2009-08-01

    Ultrasonically assisted extraction of flavour compounds from different varieties of Mentha spicata, using 70% ethanol, have been carried out for 5, 10 and 15min and coupled with under vacuum distillation. The ultrasound distilled extracts have been analysed by GC-MS and compared with essential oils obtained by hydrodistillation. The results have showed that ultrasonically assisted extraction in combination with under vacuum distillation have provided extracts with higher flavouring strength due to the increased concentration of desirable oxygenated compounds (from 5 to 8 times) compared with hydrodistillation. Extraction yields of flavour volatiles have been calculated giving a range 0.04-0.13% by ultrasound and 0.01-0.02% by hydrodistillation.

  17. Percutaneous transhepatic biliary drainage assisted by real-time virtual sonography: a retrospective study

    PubMed Central

    2013-01-01

    Background Real-time virtual sonography (RVS) is a diagnostic imaging support system that can synchronize with ultrasound images in conjunction with computed tomography or magnetic resonance images using magnetic navigation system. RVS has been applied in clinical practice to perform such procedures as radiofrequency ablation and biopsy; however, the application of RVS for percutaneous transhepatic biliary drainage (PTBD) is rare. Methods Between 2007 and 2012, RVS-assisted PTBD was performed for 30 patients (19 males and 11 females; age range, 41 to 89 years; mean age, 66.9 years) with obstructive jaundice. The targeted bile duct was determined using the RVS system before the procedure. The intervention was considered to be successful when the targeted bile duct was punctured and the drainage catheter was placed in the bile duct. Complications were evaluated according to the Society of Interventional Radiology Clinical Practice Guidelines. Results A total of 37 interventions were performed for 30 patients. The interventions were successful in 35 (95%) of 37 interventions. The targeted bile ducts were: B3 (n = 24), B5 (n = 7), B8 (n = 3), B6 (n = 1), and the anterior (n = 1) and posterior (n = 1) branches of the right bile duct. The mean targeted bile duct diameter was 4.9 mm (1.9 to 8.2 mm). PTBD was able to be accomplished in all patients because the non-targeted bile ducts were successfully punctured alternatively. No major complications were observed in relation to the interventional procedure. Conclusions RVS-assisted PTBD is a feasible and safe procedure. Accurate puncture of targeted bile ducts can be achieved using this method. PMID:23941632

  18. Gas-assisted gravity drainage (GAGD) process for improved oil recovery

    DOEpatents

    Rao, Dandina N [Baton Rouge, LA

    2012-07-10

    A rapid and inexpensive process for increasing the amount of hydrocarbons (e.g., oil) produced and the rate of production from subterranean hydrocarbon-bearing reservoirs by displacing oil downwards within the oil reservoir and into an oil recovery apparatus is disclosed. The process is referred to as "gas-assisted gravity drainage" and comprises the steps of placing one or more horizontal producer wells near the bottom of a payzone (i.e., rock in which oil and gas are found in exploitable quantities) of a subterranean hydrocarbon-bearing reservoir and injecting a fluid displacer (e.g., CO.sub.2) through one or more vertical wells or horizontal wells. Pre-existing vertical wells may be used to inject the fluid displacer into the reservoir. As the fluid displacer is injected into the top portion of the reservoir, it forms a gas zone, which displaces oil and water downward towards the horizontal producer well(s).

  19. Drying based on temperature-detection-assisted control in microwave-assisted pulse-spouted vacuum drying.

    PubMed

    Cao, Xiaohuang; Zhang, Min; Qian, He; Mujumdar, Arun S

    2017-06-01

    An online temperature-detection-assisted control system of microwave-assisted pulse-spouted vacuum drying was newly developed. By using this system, temperature control can be automatically and continuously adjusted based on the detection of drying temperature and preset temperature. Various strategies for constant temperature control, linear temperature control and three-step temperature control were applied to drying carrot cubes. Drying kinetics and the quality of various temperature-controlled strategies online are evaluated for the new drying technology as well as its suitability as an alternative drying method. Drying time in 70 °C mode 1 had the shortest drying time and lowest energy consumption in all modes. A suitable colour, highest re-hydration ratio and fracture-hardness, and longest drying time occurred in 30-40-50 °C mode 3. The number of hot spots was reduced in 40-50-60 °C mode 3. Acceptable carrot snacks were obtained in 50-60-70 °C mode 3 and 70 °C mode 2. All temperature curves showed that the actual temperatures followed the preset temperatures appropriately. With this system, a linear temperature-controlled strategy and a three-step temperature-controlled strategy can improve product quality and heating non-uniformity compared to constant temperature control, but need greater energy consumption and longer drying time. A temperature-detection-assisted control system was developed for providing various drying strategies as a suitable alternative in making a snack product. © 2016 Society of Chemical Industry. © 2016 Society of Chemical Industry.

  20. Arterial supply, venous drainage and collateral circulation in the nose of the anaesthetized dog.

    PubMed Central

    Lung, M A; Wang, J C

    1987-01-01

    1. In pentobarbitone-anaesthetized dogs, nasal blood flows were measured with electromagnetic flow sensors. 2. The terminal internal maxillary artery was found to supply 22 +/- 2.2 ml min-1 (one side) to the nasal mucosa via the sphenopalatine and major palatine branches; the artery was found to receive multiple supply routes from common carotid, vertebral and subclavian arteries. 3. Nasal mucosa was found to receive collateral flow from contralateral terminal internal maxillary artery (about 5 to 10% of normal flow) and branches of subclavian arteries (about 36% of normal flow). 4. Nasal mucosa was found to have two venous systems: the low-flow (12 +/- 1.0 ml min-1; both sides) and low-pressure (7 +/- 0.6 mmHg) sphenopalatine veins draining the posterior nasal cavity and the high-flow (30 +/- 1.4 ml min-1; both sides) and high-pressure (17 +/- 1.0 mmHg) dorsal nasal veins draining the anterior nasal cavity. 5. PO2 of nasal venous blood was found to range from 62 +/- 2.9 mmHg to 65 +/- 3.4 mmHg. During nitrogen challenge to the nose, the sphenopalatine venous PO2 dropped to 35 +/- 3.0 mmHg while the dorsal nasal venous PO2 remained unchanged, suggesting that the sphenopalatine veins were responsible for draining capillary flow and dorsal nasal veins arteriovenous anastomotic flow as well. 6. Microscopic examination of the vascular casts confirmed that arteriovenous anastomoses were located only in the anterior nasal cavity. Images Fig. 5 Plate 1 Plate 2 PMID:3443958

  1. Use of a novel drainage flow servo-controlled CPB for mitral valve replacement in a Jehovah's Witness.

    PubMed

    Niimi, Yoshinari; Murata, Seiichiro; Mitou, Yumi; Ohno, Yusuke

    2018-03-01

    We developed a novel open cardiopulmonary bypass (CPB) system, a drainage flow servo-controlled CPB system (DS-CPB), in which rotational speed of the main roller pump is servo-controlled to generate the same amount of flow as the systemic venous drainage. It was designed to safely decrease the priming volume while maintaining a constant reservoir level, even during fluctuations of the drainage flow. We report a successful use of a novel DS-CPB system in an elderly Jehovah's Witness patient with dehydration who underwent mitral valve replacement.

  2. Polyimide Composites Properties of RTM370 Fabricated by Vacuum Assisted Resins Transfer Molding (VARTM)

    NASA Technical Reports Server (NTRS)

    Chuang, Kathy C.; Criss, Jim M.; Mintz, Eric A.

    2011-01-01

    RTM370 imide resin based on 2,3,3 ,4 -biphenyl dianhydride ( a-BPDA), 3,4 -oxydianinline (3,4 -ODA) with 4-phenylethynylphthalic (PEPA) endcap has shown to exhibit high Tg (370 C) and low melt viscosity (10-30 poise) at 280 C with a pot-life of 1-2 h. Previously, RTM370 resin has been fabricated into composites with T650-35 carbon fabrics by resin transfer molding (RTM) successfully. RTM370 composites exhibit excellent mechanical properties up to 327 C (620 F), and outstanding property retention after aging at 288 C (550 F) for 1000 hrs. In this presentation, RTM 370 composites will be fabricated by vacuum assisted resins transfer molding (VARTM), using vacuum bags without mold. The mechanical properties of RTM370 composites fabricated by VARTM will be compared to those of RTM370 made by RTM.

  3. Illinois drainage water management demonstration project

    USGS Publications Warehouse

    Pitts, D.J.; Cooke, R.; Terrio, P.J.; ,

    2004-01-01

    Due to naturally high water tables and flat topography, there are approximately 4 million ha (10 million ac) of farmland artificially drained with subsurface (tile) systems in Illinois. Subsurface drainage is practiced to insure trafficable field conditions for farm equipment and to reduce crop stress from excess water within the root zone. Although drainage is essential for economic crop production, there have been some significant environmental costs. Tile drainage systems tend to intercept nutrient (nitrate) rich soil-water and shunt it to surface water. Data from numerous monitoring studies have shown that a significant amount of the total nitrate load in Illinois is being delivered to surface water from tile drainage systems. In Illinois, these drainage systems are typically installed without control mechanisms and allow the soil to drain whenever the water table is above the elevation of the tile outlet. An assessment of water quality in the tile drained areas of Illinois showed that approximately 50 percent of the nitrate load was being delivered through the tile systems during the fallow period when there was no production need for drainage to occur. In 1998, a demonstration project to introduce drainage water management to producers in Illinois was initiated by NRCS4 An initial aspect of the project was to identify producers that were willing to manage their drainage system to create a raised water table during the fallow (November-March) period. Financial assistance from two federal programs was used to assist producers in retrofitting the existing drainage systems with control structures. Growers were also provided guidance on the management of the structures for both water quality and production benefits. Some of the retrofitted systems were monitored to determine the effect of the practice on water quality. This paper provides background on the water quality impacts of tile drainage in Illinois, the status of the demonstration project, preliminary

  4. Flow and Compaction During the Vacuum Assisted Resin Transfer Molding Process

    NASA Technical Reports Server (NTRS)

    Grimsley, Brian W.; Hubert, Pascal; Song, Xiao-Lan; Cano, Roberto J.; Loos, Alfred C.; Pipes, R. Byron

    2001-01-01

    The flow of an epoxy resin and compaction behavior of carbon fiber preform during vacuum- assisted resin transfer molding (VARTM) infiltration was measured using an instrumented tool. Composite panels were fabricated by the VARTM process using SAERTEX(R)2 multi-axial non- crimp carbon fiber fabric and the A.T.A.R.D. SI-ZG-5A epoxy resin. Resin pressure and preform thickness variation was measured during infiltration. The effects of the resin on the compaction behavior of the preform were measured. The local preform compaction during the infiltration is a combination of wetting and spring-back deformations. Flow front position computed by the 3DINFIL model was compared with the experimental data.

  5. Massive multicystic dilatation of the uterine wall with myometrial venous thrombosis during pregnancy.

    PubMed

    Uotila, J; Dastidar, P; Martikainen, P; Kirkinen, P

    2004-09-01

    We present a pregnancy complicated by multicystic dilatation of the uterine wall during the second trimester, leading to massive uterine distension, anemia and preterm Cesarean section. The cystic changes detected by ultrasound and magnetic resonance imaging involved the whole uterine wall surrounding the entire amniotic cavity. Histopathological examination revealed the benign nature of the cystic changes, which represented dilated and thrombosed venous lacunae. Disturbed venous drainage, combined with local thrombosis, was likely to have led to the collection of a large volume of blood in the uterine wall and the subsequent multicystic change of the myometrium. Copyright 2004 ISUOG

  6. Arterial spin labeling MR imaging aids to identify cortical venous drainage of dural arteriovenous fistulas.

    PubMed

    Kang, Ji Hee; Yun, Tae Jin; Rhim, Jong Kook; Cho, Young Dae; Yoo, Dong Hyun; Yoo, Roh-Eul; Kang, Koung Mi; Choi, Seung Hong; Kim, Ji-Hoon; Sohn, Chul-Ho; Han, Moon Hee

    2018-05-01

    Cortical venous drainage (CVD) increases the probability of intracranial hemorrhage and mortality rate of dural arteriovenous fistulas (DAVF). Although digital subtraction angiography (DSA) is the most accurate method to determine CVD in DAVFs, this modality has limitations due to its invasive nature and radiation issues. The purpose of this study was to evaluate the diagnostic utility of arterial spin-labeling perfusion-weighted images (ASL-PWI) to identify CVD in patients with DAVF.The Institutional Review Board of our hospital approved this retrospective study. ASL-PWI features of 22 patients with DAVF were retrospectively reviewed for the presence of bright signal intensity in cortical veins and brain parenchyma. DAVF with bright signal intensity in cortical veins and/or brain parenchyma was regarded as having CVD. Using DSA as a reference standard, sensitivity, specificity, positive predictive value, and negative predictive value of ASL-PWI for detecting CVD were calculated.Based on DSA features, 11 (11/22, 50%) patients were classified as having "aggressive" pattern with CVD. Eleven (11/22, 50%) patients also showed bright signal intensity in cortical veins (9/22, 41%) and/or brain parenchyma (4/22, 18%) on ASL-PWI. The 11 patients who had "Aggressive" pattern on DSA were the same 11 patients who were classified as having "aggressive" pattern on ASL-PWI. ASL-PWI showed perfect diagnostic performance for identifying CVD with sensitivity, specificity, positive predictive value, and negative predictive value of 100% for all.Thus, ASL-PWI could be used as a noninvasive mean to predict the presence of CVD in patients with DAVFs. It has the potential as a screening tool to evaluate DAVF prior to invasive DSA.

  7. Composite Properties of RTM370 Polyimide Fabricated by Vacuum Assisted Resin Transfer Molding (VARTM)

    NASA Technical Reports Server (NTRS)

    Chuang, Kathy C.; Criss, James M.; Mintz, Eric A.; Shonkwiler, Brian; McCorkle, Linda S.

    2011-01-01

    RTM370 imide resin based on 2,3,3?,4?-biphenyl dianhydride (a-BPDA), 3,4'-oxydianinline (3,4'-ODA) with the 4-phenylethynylphthalic (PEPA) endcap has been shown to exhibit a high cured T(sub g) (370 C) and low melt viscosity (10-30 poise) at 280 C with a pot-life of 1-2 h. Previously, RTM370 resin has been successfully fabricated into composites reinforced with T650-35 carbon fabrics by resin transfer molding (RTM). RTM370 composites exhibit excellent mechanical properties up to 327?C (620?F), and outstanding property retention after aging at 288?C (550?F) for 1000 h. In this work, RTM370 composites were fabricated by vacuum assisted resin transfer molding (VARTM), using vacuum bags on a steel plate. The mechanical properties of RTM370 composites fabricated by VARTM are compared to those prepared by RTM.

  8. [The evolution of vacuum extraction in obstetrics].

    PubMed

    Nikolov, A

    2010-01-01

    Vacuum extraction is one of the methods for assisted vaginal delivery. In this article the evolution of vacuum extraction in obstetrics is been discussed. Historical facts and data from the invention up to state-of-the-art vacuum systems in modern obstetrics are presented.

  9. Homogenate-assisted Vacuum-powered Bubble Extraction of Moso Bamboo Flavonoids for On-line Scavenging Free Radical Capacity Analysis.

    PubMed

    Sun, Yinnan; Yang, Kui; Cao, Qin; Sun, Jinde; Xia, Yu; Wang, Yinhang; Li, Wei; Ma, Chunhui; Liu, Shouxin

    2017-07-11

    A homogenate-assisted vacuum-powered bubble extraction (HVBE) method using ethanol was applied for extraction of flavonoids from Phyllostachys pubescens (P. pubescens) leaves. The mechanisms of homogenate-assisted extraction and vacuum-powered bubble generation were discussed in detail. Furthermore, a method for the rapid determination of flavonoids by HPLC was established. HVBE followed by HPLC was successfully applied for the extraction and quantification of four flavonoids in P. pubescens , including orientin, isoorientin, vitexin, and isovitexin. This method provides a fast and effective means for the preparation and determination of plant active components. Moreover, the on-line antioxidant capacity, including scavenging positive ion and negative ion free radical capacity of different fractions from the bamboo flavonoid extract was evaluated. Results showed that the scavenging DPPH ˙ free radical capacity of vitexin and isovitexin was larger than that of isoorientin and orientin. On the contrary, the scavenging ABTS⁺ ˙ free radical capacity of isoorientin and orientin was larger than that of vitexin and isovitexin.

  10. An effective vacuum assisted extraction method for the optimization of labdane diterpenoids from Andrographis paniculata by response surface methodology.

    PubMed

    Wang, Ya-Qi; Wu, Zhen-Feng; Ke, Gang; Yang, Ming

    2014-12-31

    An effective vacuum assisted extraction (VAE) technique was proposed for the first time and applied to extract bioactive components from Andrographis paniculata. The process was carefully optimized by response surface methodology (RSM). Under the optimized experimental conditions, the best results were obtained using a boiling temperature of 65 °C, 50% ethanol concentration, 16 min of extraction time, one extraction cycles and a 12:1 liquid-solid ratio. Compared with conventional ultrasonic assisted extraction and heat reflux extraction, the VAE technique gave shorter extraction times and remarkable higher extraction efficiency, which indicated that a certain degree of vacuum gave the solvent a better penetration of the solvent into the pores and between the matrix particles, and enhanced the process of mass transfer. The present results demonstrated that VAE is an efficient, simple and fast method for extracting bioactive components from A. paniculata, which shows great potential for becoming an alternative technique for industrial scale-up applications.

  11. Scimitar sign with normal pulmonary venous drainage and anomalous inferior vena cava.

    PubMed Central

    Herer, B; Jaubert, F; Delaisements, C; Huchon, G; Chretien, J

    1988-01-01

    A case of the scimitar sign due to an anomaly of the right sided pulmonary vein with normal drainage into the left atrium was associated with an azygos continuation of the inferior vena cava. Digital subtraction angiography allows the identification of these rare congenital vascular malformations. Images PMID:3175980

  12. Model of complete separation of the hepatic veins from the systemic venous system.

    PubMed

    Brizard, C P; Goussef, N; Chachques, J C; Carpentier, A F

    2000-12-01

    In patients undergoing a Fontan operation, partial diversion of the hepatic veins to the pulmonary venous atrium has been tried with various techniques. They failed because of the development of intrahepatic collaterals leading to an unacceptable right-to-left shunting. We postulate that to avoid the formation of intrahepatic collaterals, the totality of the liver has to be drained into the same pressure compartment. We have designed a model of cavopulmonary anastomosis in which a prosthetic conduit reproduces an azygos continuation, associated with the diversion of the totality of the hepatic venous return. This article reports on the early hemodynamics and the fate of the separation of the two venous compartments in long-term survivors. Eighteen goats were operated on; the pulmonary artery and hepatic vein pressures were recorded. During month 2, an opacification of the inferior vena cava and the cavopulmonary connection was performed. Between months 6 and 14, another opacification was performed, together with pressure recording at both ends of the conduit. Postoperatively the pulmonary artery pressure was pulsatile with a mean of 10 mm Hg and the hepatic vein pressure was 0 mm Hg. The first angiogram showed patent tubes with fast progression of the contrast. Throughout the inferior vena cava injection, there was no opacification of the portal or hepatic veins. The late study showed a narrowed conduit in all animals. During the injection, a collateral was injected, feeding into the inferior mesenteric vein. No collateral circulation could be seen draining directly into the liver. The median gradient between the two ends of the conduit was 11 mm Hg. The isolation of the entire hepatic venous drainage is feasible and efficient for the separation of two pressure compartments. No intrahepatic collaterals are observed with this model at short- or long-term follow-up. The separation of the hepatic venous drainage should persist without collateral circulation as long as

  13. Evaluation of capillary permeability and microcirculation in patients with chronic venous hypertension treated with venoruton by the vacuum suction chamber (VSC) device and laser-Doppler flowmetry.

    PubMed

    Belcaro, G; D'Aulerio, A; Rulo, A; Candiani, C

    1988-01-01

    A new system to study capillary permeability, the VSC (vacuum suction chamber) device has been developed to evaluate the variations of capillary permeability in postphlebitic limbs. The VSC device produces by negative pressure [obtained in a plastic chamber applied to the skin at the perimalleolar region] a wheal which disappears in normals in less than one hour. In twelve patients with moderate [superficial] venous hypertension and in twelve patients with postphlebitic limbs the time of disappearance of the wheals was significantly longer in comparison with ten normal limbs. There was also a significantly increased time of disappearance of the wheals in postphlebitic legs in comparison with those with superficial incompetence. The validation of the VSC technique with venous occlusion plethysmography (VOP) showed that the increase of time of disappearance of the wheals is well correlated with the increase of capillary permeability demonstrated by VOP. After 2 weeks treatment with Venoruton (at the dosage of 1000 mg t.i.d.) the time of disappearance of the wheal was significantly reduced in both groups of patients (while it was unchanged in normals). Laser-Doppler parameters used together with the VSC device to evaluate the microcirculatory changes associated with an altered capillary permeability also showed a significant improvement of the laser-Doppler parameters after treatment. In conclusion there is evidence by the VSC device that capillary permeability [which is abnormally increased] in chronic venous hypertension is improved [decreased] after treatment for two weeks with Venoruton. This study demonstrated also the efficacy of the VSC device to study capillary permeability and the effects of drugs active on capillary permeability.

  14. Randomized, controlled pilot study comparing large-volume paracentesis using wall suction and traditional glass vacuum bottle methods.

    PubMed

    Konerman, Monica A; Price, Jennifer; Torres, Dawn; Li, Zhiping

    2014-09-01

    Large-volume paracentesis (LVP) can be time and labor intensive depending on the amount of ascites removed and the method of drainage. Wall suction has been adopted as the preferred method of drainage at many centers, though the safety and benefits of this technique have not been formally evaluated. The primary objective of this study was to define the cost and time savings of wall suction over the traditional glass vacuum bottle method for ascites drainage. The secondary objective was to compare the safety profile and patient satisfaction using these two techniques. We conducted a randomized, controlled pilot study of the wall suction versus vacuum bottle methods for LVP in hospitalized patients. All LVPs were performed under ultrasound guidance by a single proceduralist. Patients with at least 4 liters removed received 25% intravenous albumin, 8 g/liter fluid removed. Demographic, clinical characteristics, and procedure details were recorded. Laboratory and hemodynamic data were recorded for 24 h prior to and 24-48 h post LVP. An electronic chart review was conducted to evaluate procedure-related complications. Data were compared using Fisher's exact test, t test, or Mann-Whitney U test. Thirty-four patients were randomized to wall suction at 200 mmHg (n = 17) or glass vacuum bottle drainage (n = 17). Wall suction was significantly faster and less costly than vacuum bottle drainage (7 versus 15 min, p = 0.002; $4.59 versus $12.73, p < 0.001). There were no differences in outcomes at 24 and 48 h post LVP, or at 60-day follow up. Performing LVP using wall suction resulted in significantly shorter procedure time and supply cost savings. There were no differences in outcomes between the groups, suggesting equivalent safety, though larger studies powered to detect small differences are needed. Given its efficiency, convenience, and cost effectiveness, wall suction may be a superior method of ascites drainage for LVP.

  15. The Ovine Cerebral Venous System: Comparative Anatomy, Visualization, and Implications for Translational Research

    PubMed Central

    Nitzsche, Björn; Lobsien, Donald; Seeger, Johannes; Schneider, Holm; Boltze, Johannes

    2014-01-01

    Cerebrovascular diseases are significant causes of death and disability in humans. Improvements in diagnostic and therapeutic approaches strongly rely on adequate gyrencephalic, large animal models being demanded for translational research. Ovine stroke models may represent a promising approach but are currently limited by insufficient knowledge regarding the venous system of the cerebral angioarchitecture. The present study was intended to provide a comprehensive anatomical analysis of the intracranial venous system in sheep as a reliable basis for the interpretation of experimental results in such ovine models. We used corrosion casts as well as contrast-enhanced magnetic resonance venography to scrutinize blood drainage from the brain. This combined approach yielded detailed and, to some extent, novel findings. In particular, we provide evidence for chordae Willisii and lateral venous lacunae, and report on connections between the dorsal and ventral sinuses in this species. For the first time, we also describe venous confluences in the deep cerebral venous system and an ‘anterior condylar confluent’ as seen in humans. This report provides a detailed reference for the interpretation of venous diagnostic imaging findings in sheep, including an assessment of structure detectability by in vivo (imaging) versus ex vivo (corrosion cast) visualization methods. Moreover, it features a comprehensive interspecies-comparison of the venous cerebral angioarchitecture in man, rodents, canines and sheep as a relevant large animal model species, and describes possible implications for translational cerebrovascular research. PMID:24736654

  16. An Isolated Venous Sac as a Novel Site for Cell Therapy in Diabetes Mellitus

    PubMed Central

    Kakabadze, Zurab; Shanava, Koba; Ricordi, Camillo; Shapiro, A.M. James; Gupta, Sanjeev; Berishvili, Ekaterine

    2013-01-01

    Background Transplanting pancreatic islets is of significant interest for type 1 diabetes mellitus. After intraportal injection of islets, inferior engraftment and eventual loss of transplanted islets constitute major limitations. Therefore, alternative approaches will be helpful. Here, we evaluated in animals whether an isolated venous sac would support survival of transplanted islets, along with correction of hyperglycemia. Methods Pancreatic islets isolated from adult Lewis rats were transplanted either into an isolated venous sac made from lumbar vein or into the portal vein of syngeneic rats. The integrity and vascular organization of the venous sac was determined by studies of the local microcirculation. The engraftment, survival, and function of transplanted islets were analyzed by histology, including endocrine function in situ and by glycemic control in rats with streptozotocin-induced diabetes. Results Transplanted islets showed normal morphology with insulin expression in isolated venous sac during the long term. Transplanted islets received blood supply from vasa vasorum and had access to drainage through venous tributaries in the venous sac. This resulted in restoration of euglycemia in diabetic rats. Removal of islet graft-bearing venous sac in diabetic rats led to recurrence of hyperglycemia. By contrast, euglycemia was not restored in rats treated by intraportal transplantation of islets. Conclusions We demonstrated that pancreatic islets successfully engrafted and functioned in the isolated venous sac with ability to restore euglycemia in diabetic rats. Therefore, the isolated venous sac offers a new site for transplantation of pancreatic islets. This would be clinically beneficial as an alternative to intrahepatic islet transplantation. PMID:22814331

  17. Integrated Cooling-Vacuum-Assisted Non-Fractional 1540 nm Erbium:Glass Laser is Effective in Treating Acne Scars.

    PubMed

    Politi, Yael; Levi, Assi; Lapidoth, Moshe

    2016-11-01

    Acne scars are a common result of in ammatory acne, affecting many patients worldwide. Among which, atrophic scars are the most prevalent form, presenting as dermal depressions caused by inflammatory degeneration of dermal collagen. Mid-infrared laser skin interaction is characterized by its modest absorption in water and nite penetration to the mid-dermis. Since collagen is a desirable laser target, 1540-nm wavelength is amenable for collagen remodeling within the depressed area of atrophic scars. To evaluate the safety and efficacy of acne scars treatment using an integrated cooling-vacuum-assisted 1540 nm Erbium: Glass Laser. This interventional prospective study included 25 volunteers (10 men, 15 women) with post acne atrophic scars. Patients were treated with a mid-infrared non-fractional 1540 nm Er:Glass laser (Alma Lasers Ltd. Caesarea, Israel) with integrat- ed cooling- vacuum assisted technology. Acne scars were exposed to 3 stacked laser pulses (400-600 mJ/pulse, 4 mm spot size, frequency of 3 Hz). Patients underwent 3-6 treatment sessions with a 2-3 week interval and were followed-up 1 month and 3 months after the last treatment. Clinical photographs were taken by high resolution digital camera before and after treatment. Clinical evaluation was performed by two independent dermatologists and results were graded on a scale of 0 (exacerbation) to 4 (76%-100% improvement). Patients' and physicians' satisfaction were also recorded (on a 1-5 scale). Pain perception and adverse effects were evaluated as well. Almost all patients (24/25) demonstrated a moderate to significant improvement. Average improvement was 3.9 and 4.1 points on the quartile scale used for outcome assessment 1 and 3 months following the last session, respectively. Patient satisfaction rate was 4.2. Side effects were minimal and transient: erythema, mild transient vesicles, and mild pain or inconvenience. CONCLUSION Cooling-Vacuum-Assisted mid-infrared non-fractional Er:Glass 1540 nm laser

  18. Histology after lumpectomy in women with epithelial atypia on stereotactic vacuum-assisted breast biopsy.

    PubMed

    Graesslin, O; Antoine, M; Chopier, J; Seror, J Y; Flahault, A; Callard, P; Daraï, E; Uzan, S

    2010-02-01

    Large-core needle biopsy of the breast (LCNB) and vacuum-assisted breast biopsy (VABB) are widely used as alternatives to open surgical biopsy (OSB) for initial diagnosis of mammographic abnormalities. Between 18% and 80% of cases in which such specimens show atypical lobular hyperplasia (ALH) or atypical ductal hyperplasia (ADH) are found to be malignant at surgery. From 1999 to 2005, 68 women with mammographic abnormalities were sampled by stereotactic VABB and presented atypical epithelial hyperplasia. Immunohistochemical staining with anti-cytokeratin 5/6 and anti-E-cadherin antibodies was performed. All women underwent a lumpectomy. Clinical, radiological or histological factors predictive of the risk of finding malignancy at surgery were sought. VABB initially showed 28 cases of ADH, 32 cases of ALH, one case of flat epithelial atypia, five cases of mixed atypia, and two cases of Lobular Carcinoma In Situ (LCIS). After slide review with immunohistochemical staining, two cases of ADH were reclassified as simple hyperplasia and two cases of ALH were reclassified as mixed atypia. Seven lesions (10.3%) that appeared to be benign on VABB were found to be malignant on OSB (Ductal Carcinoma In Situ (DCIS) in six cases and invasive ductal carcinoma in one case). ADH was the only predictive factor of malignancy on OSB (p=0.04 versus ALH). ADH diagnosed by vacuum-assisted breast biopsy frequently corresponds to cancer on open surgical biopsy. Surgical excision of all breast lesions containing atypical hyperplasia on percutaneous biopsy can be recommended. Copyright (c) 2009 Elsevier Ltd. All rights reserved.

  19. Pancreas Transplant Venous Thrombosis: Role of Endovascular Interventions for Graft Salvage

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Stockland, Andrew H.; Willingham, Darrin L.; Paz-Fumagalli, Ricardo

    2009-03-15

    Venous thrombosis of pancreas transplant allografts often leads to graft loss. We evaluated the efficacy of emergent endovascular techniques to salvage thrombosed pancreatic allografts in a series of six patients. Of the 76 pancreas transplants performed between 2002 and 2006, six patients were diagnosed with venous thrombosis on MRI between 2 and 28 days posttransplant (mean, 9 days). Five patients were systemic-enteric (donor portal vein anastomosis to recipient iliac vein) and one patient was portal-enteric (donor portal vein anastomosis to recipient superior mesenteric vein). Conventional venography confirmed the diagnosis of venous thrombosis in all patients. One patient was treated withmore » catheter-directed venous thrombolysis and balloon thrombectomy. Another patient was treated with rheolytic thrombectomy alone. The remaining four patients were treated with a combination of these mechanical and thrombolytic techniques. Completion venography revealed >50% clot reduction and resumption of venous drainage in all patients. One patient required additional intervention 16 days later for recurrent thrombosis. Two patients required metal stent placement for anastomotic stenoses or kinks. One patient required pancreatectomy 36 h after attempted salvage secondary to a major hemorrhage and graft necrosis. Two patients recovered pancreatic function initially but lost graft function at 8 and 14 months, respectively, from severe chronic rejection. Patient survival was 100%, long-term graft survival was 50%, rethrombosis rate was 16.6%, and graft loss from rejection was 33%. In conclusion, early recognition and treatment of venous thrombosis after pancreas transplantation has acceptable morbidity and no mortality using short-term endovascular pharmacomechanical therapy.« less

  20. Magnet Assisted Composite Manufacturing: A Flexible New Technique for Achieving High Consolidation Pressure in Vacuum Bag/Lay-Up Processes.

    PubMed

    Pishvar, Maya; Amirkhosravi, Mehrad; Altan, M Cengiz

    2018-05-17

    This work demonstrates a protocol to improve the quality of composite laminates fabricated by wet lay-up vacuum bag processes using the recently developed magnet assisted composite manufacturing (MACM) technique. In this technique, permanent magnets are utilized to apply a sufficiently high consolidation pressure during the curing stage. To enhance the intensity of the magnetic field, and thus, to increase the magnetic compaction pressure, the magnets are placed on a magnetic top plate. First, the entire procedure of preparing the composite lay-up on a magnetic bottom steel plate using the conventional wet lay-up vacuum bag process is described. Second, placement of a set of Neodymium-Iron-Boron permanent magnets, arranged in alternating polarity, on the vacuum bag is illustrated. Next, the experimental procedures to measure the magnetic compaction pressure and volume fractions of the composite constituents are presented. Finally, methods used to characterize microstructure and mechanical properties of composite laminates are discussed in detail. The results prove the effectiveness of the MACM method in improving the quality of wet lay-up vacuum bag laminates. This method does not require large capital investment for tooling or equipment and can also be used to consolidate geometrically complex composite parts by placing the magnets on a matching top mold positioned on the vacuum bag.

  1. Application of BIM Technology in Building Water Supply and Drainage Design

    NASA Astrophysics Data System (ADS)

    Wei, Tianyun; Chen, Guiqing; Wang, Junde

    2017-12-01

    Through the application of BIM technology, the idea of building water supply and drainage designers can be related to the model, the various influencing factors to affect water supply and drainage design can be considered more comprehensively. BIM(Building information model) technology assist in improving the design process of building water supply and drainage, promoting the building water supply and drainage planning, enriching the building water supply and drainage design method, improving the water supply and drainage system design level and building quality. Combined with fuzzy comprehensive evaluation method to analyze the advantages of BIM technology in building water supply and drainage design. Therefore, application prospects of BIM technology are very worthy of promotion.

  2. The role of noninvasive and invasive diagnostic imaging techniques for detection of extra-cranial venous system anomalies and developmental variants

    PubMed Central

    2013-01-01

    The extra-cranial venous system is complex and not well studied in comparison to the peripheral venous system. A newly proposed vascular condition, named chronic cerebrospinal venous insufficiency (CCSVI), described initially in patients with multiple sclerosis (MS) has triggered intense interest in better understanding of the role of extra-cranial venous anomalies and developmental variants. So far, there is no established diagnostic imaging modality, non-invasive or invasive, that can serve as the “gold standard” for detection of these venous anomalies. However, consensus guidelines and standardized imaging protocols are emerging. Most likely, a multimodal imaging approach will ultimately be the most comprehensive means for screening, diagnostic and monitoring purposes. Further research is needed to determine the spectrum of extra-cranial venous pathology and to compare the imaging findings with pathological examinations. The ability to define and reliably detect noninvasively these anomalies is an essential step toward establishing their incidence and prevalence. The role for these anomalies in causing significant hemodynamic consequences for the intra-cranial venous drainage in MS patients and other neurologic disorders, and in aging, remains unproven. PMID:23806142

  3. [Effect of ozonated water on physical and chemical properties of vacuum sealing drainage material].

    PubMed

    Jiang, Nan; Ma, Yunfei; Lin, Qingrong; Chen, Anfu; Zhao, Peiran; Ni, Guoxin; Yu, Bin

    2013-02-01

    To investigate the influence of ozonated water on physical and chemical properties of vacuum sealing drainage (VSD) materials. VSD materials (foam and sealing membrane) were immersed in 10 µg/ml ozonated water for 1 h twice daily for 8 days. The foam appearance and microscopic structure of the materials were observed, and tensile tests and Raman spectrum scan were performed assess the effect of ozonated water. Simulated VSD devices were prepared and tested for leakproofness under negative pressure after ozonated water treatment. zonated water treatment for 8 days caused no obvious abnormal changes in the foam appearance or microscopic structure of the materials. The maximum tensile load of foam before and after ozonated water treatment was 4.25∓0.73 kgf and 2.44∓0.19 kgf (P=0.000), the momentary distance when the foam torn before and after intervention was 92.54∓12.83 mm and 64.44∓4.60 mm, respectively (P=0.000). The corresponding results for VSD sealing membrane were 0.70∓0.58 kgf and 0.71∓0.08 kgf (P=0.698), and 99.30∓10.27 mm and 100.95∓18.22 mm (P=0.966), respectively. Raman spectroscopy revealed changes in only several wave intensities and no new chemical groups appeared within the scan range of 400-4000 cm(-1). The VSD device was well hermetic after treatment with ozonated water. Except for a decreased stretch resistance property of the foam, VSD materials display no obvious changes in physical and chemical characteristics after treatment with ozonated water for 8 days.

  4. Pilot study of a novel vacuum-assisted method for decellularization of tracheae for clinical tissue engineering applications.

    PubMed

    Lange, P; Greco, K; Partington, L; Carvalho, C; Oliani, S; Birchall, M A; Sibbons, P D; Lowdell, M W; Ansari, T

    2017-03-01

    Tissue engineered tracheae have been successfully implanted to treat a small number of patients on compassionate grounds. The treatment has not become mainstream due to the time taken to produce the scaffold and the resultant financial costs. We have developed a method for decellularization (DC) based on vacuum technology, which when combined with an enzyme/detergent protocol significantly reduces the time required to create clinically suitable scaffolds. We have applied this technology to prepare porcine tracheal scaffolds and compared the results to scaffolds produced under normal atmospheric pressures. The principal outcome measures were the reduction in time (9 days to prepare the scaffold) followed by a reduction in residual DNA levels (DC no-vac: 137.8±48.82 ng/mg vs. DC vac 36.83±18.45 ng/mg, p<0.05.). Our approach did not impact on the collagen or glycosaminoglycan content or on the biomechanical properties of the scaffolds. We applied the vacuum technology to human tracheae, which, when implanted in vivo showed no significant adverse immunological response. The addition of a vacuum to a conventional decellularization protocol significantly reduces production time, whilst providing a suitable scaffold. This increases clinical utility and lowers production costs. To our knowledge this is the first time that vacuum assisted decellularization has been explored. Copyright © 2015 John Wiley & Sons, Ltd. Copyright © 2015 John Wiley & Sons, Ltd.

  5. Computed tomographic characteristics of collateral venous pathways in dogs with caudal vena cava obstruction.

    PubMed

    Specchi, Swan; d'Anjou, Marc-André; Carmel, Eric Norman; Bertolini, Giovanna

    2014-01-01

    Collateral venous pathways develop in dogs with obstruction or increased blood flow resistance at any level of the caudal vena cava in order to maintain venous drainage to the right atrium. The purpose of this retrospective study was to describe the sites, causes of obstruction, and configurations of venous collateral pathways for a group of dogs with caudal vena cava obstruction. Computed tomography databases from two veterinary hospitals were searched for dogs with a diagnosis of caudal vena cava obstruction and multidetector row computed tomographic angiographic (CTA) scans that included the entire caudal vena cava. Images for each included dog were retrieved and collateral venous pathways were characterized using image postprocessing and a classification system previously reported for humans. A total of nine dogs met inclusion criteria and four major collateral venous pathways were identified: deep (n = 2), portal (n = 2), intermediate (n = 7), and superficial (n = 5). More than one collateral venous pathway was present in 5 dogs. An alternative pathway consisting of renal subcapsular collateral veins, arising mainly from the caudal pole of both kidneys, was found in three dogs. In conclusion, findings indicated that collateral venous pathway patterns similar to those described in humans are also present in dogs with caudal vena cava obstruction. These collateral pathways need to be distinguished from other vascular anomalies in dogs. Postprocessing of multidetector-row CTA images allowed delineation of the course of these complicated venous pathways and may be a helpful adjunct for treatment planning in future cases. © 2014 American College of Veterinary Radiology.

  6. Chronic cerebro-spinal venous insufficiency (CCSVI) and multiple sclerosis.

    PubMed

    Ghezzi, A; Comi, G; Federico, A

    2011-02-01

    Multiple sclerosis (MS) is an inflammatory demyelinating disease of the CNS caused by the interplay of genetic and environmental factors. In the last years, it has been suggested that an abnormal venous drainage due to stenosis or malformation of the internal jugular and/or azygous veins may play a major pathogenetic role in MS. This abnormality called chronic cerebro-spinal venous insufficiency (CCSVI) could result in increased permeability of blood brain barrier, local iron deposition and secondary multifocal inflammation. In the present paper, literature data in favour and against this hypothesis are reported. A great variability of CCSVI has been found in both MS patients (ranging from 0 to 100%) and in control subjects (from 0 to 23%). This large variability is explained by methodological aspects, problems in assessing CCSVI, and differences among clinical series. It is urgent to perform appropriate epidemiological studies to define the possible relationship between CCSVI and MS.

  7. Rescue N-butyl-2 cyanoacrylate embolectomy using a Solitaire FR device after venous glue migration during arteriovenous malformation embolization: technical note.

    PubMed

    Fahed, Robert; Clarençon, Frédéric; Sourour, Nader-Antoine; Chauvet, Dorian; Le Jean, Lise; Chiras, Jacques; Di Maria, Federico

    2016-07-01

    One of the procedural risks in arteriovenous malformation (AVM) embolization is possible migration of the embolic agent into the venous drainage with an incomplete nidus occlusion, which may lead to severe hemorrhagic complications. This report presents the case of a 29-year-old man who presented with a deep intraparenchymal hematoma on the left side secondary to the spontaneous rupture of a claustral AVM. Upon resorption of the hematoma, the patient underwent an initial therapeutic session of N-butyl-2 cyanoacrylate endovascular embolization, with the purpose of reducing the AVM volume and flow before performing Gamma Knife radiosurgery. After glue injection into one of the arterial feeders, the control angiography showed a partial migration of the glue cast into the straight sinus, with most of the nidus still visible. Because of the bleeding risk due to possible venous hypertension, it was decided to try to retrieve the glue from the vein by using a stent retriever via jugular access. This maneuver allowed a nearly complete removal of the glue cast, thereby restoring normal venous flow drainage. The patient showed no clinical worsening after the procedure. To the authors' knowledge, this is the first report of the use of the Solitaire FR device as a rescue glue retriever. This method should be considered by physicians in cases of unintended glue migration into the venous circulation during AVM embolization.

  8. An analytical solution for two-dimensional vacuum preloading combined with electro-osmosis consolidation using EKG electrodes

    PubMed Central

    Qiu, Chenchen; Li, Yande

    2017-01-01

    China is a country with vast territory, but economic development and population growth have reduced the usable land resources in recent years. Therefore, reclamation by pumping and filling is carried out in eastern coastal regions of China in order to meet the needs of urbanization. However, large areas of reclaimed land need rapid drainage consolidation treatment. Based on past researches on how to improve the treatment efficiency of soft clay using vacuum preloading combined with electro-osmosis, a two-dimensional drainage plane model was proposed according to the Terzaghi and Esrig consolidation theory. However, the analytical solution using two-dimensional plane model was never involved. Current analytical solutions can’t have a thorough theoretical analysis of practical engineering and give relevant guidance. Considering the smearing effect and the rectangle arrangement pattern, an analytical solution is derived to describe the behavior of pore-water and the consolidation process by using EKG (electro-kinetic geo synthetics) materials. The functions of EKG materials include drainage, electric conduction and corrosion resistance. Comparison with test results is carried out to verify the analytical solution. It is found that the measured value is larger than the applied vacuum degree because of the stacking effect of the vacuum preloading and electro-osmosis. The trends of the mean measured value and the mean analytical value processes are comparable. Therefore, the consolidation model can accurately assess the change in pore-water pressure and the consolidation process during vacuum preloading combined with electro-osmosis. PMID:28771496

  9. Abdominal Subcutaneous Mass After Laser-Assisted Lipolysis and Immediate Multiple Treatments with a Dual-Wavelength Laser, Vacuum and Massage Device.

    PubMed

    Gentileschi, Stefano; Servillo, Maria; D'Ettorre, Marco; Salgarello, Marzia

    2016-04-01

    Body contouring by means of minimally invasive procedures is a growing trend. Current approaches to body contouring often involve a combination of surgical techniques (eg, laser-assisted liposuction) and a series of noninvasive device-based treatments aimed at accelerating recovery and improving aesthetic outcomes. In this case study, we describe a 38-year-old woman who presented with an abdominal-wall mass that resembled a tumor when assessed with magnetic resonance imaging. Twenty-six months before presenting to our office, the patient had undergone laser lipolysis and a series of treatments with a device that delivered dual-wavelength laser energy and vacuum-assisted massage. To address the patient's concerns, we removed the mass and performed abdominal dermolipectomy. No postoperative complications occurred, and the patient was highly satisfied with the aesthetic outcome. The results of histologic studies indicated that the mass was pseudocystic and fluid-filled, surrounded by a fibrous capsule, and characterized as a foreign-body granuloma. Further analysis is warranted regarding the safety of laser lipolysis without aspiration combined with a device delivering dual-wavelength laser energy and vacuum-assisted massage. 5 Risk. © 2015 The American Society for Aesthetic Plastic Surgery, Inc. Reprints and permission: journals.permissions@oup.com.

  10. Spontaneous Hemothorax Caused by Pulmonary Micro-Venous Hemangioma.

    PubMed

    Homma, Takahiro; Yamamoto, Yutaka; Imura, Johji; Doki, Yoshinori; Yoshimura, Naoki; Senda, Kazutaka; Toge, Masayoshi; Ojima, Toshihiro; Shimada, Yoshifumi; Masawa, Nobuhide

    2015-07-01

    Various etiologies of spontaneous hemothorax have been reported, though the cause remains unidentified in some patients despite an exploratory thoracotomy. We report on an 89-year-old man with spontaneous hemothorax resolved by partial resection of the lung using complete video-assisted thoracoscopic surgery. The histopathologic findings revealed a ruptured micro-venous hemangioma located just below the bleeding visceral pleura. To the best of our knowledge, this is the first report of spontaneous hemothorax caused by a pulmonary micro-venous hemangioma. Copyright © 2015 The Society of Thoracic Surgeons. Published by Elsevier Inc. All rights reserved.

  11. Early Conversion of External Fixation to Interlocked Nailing in Open Fractures of Both Bone Leg Assisted with Vacuum Closure (VAC) - Final Outcome

    PubMed Central

    Raj, Manish; Kumar, Sunil; Singh, Pulkesh; Kumar, Dinesh; Singh, Jasveer; Deep, Akash

    2016-01-01

    Introduction Management of compound grade III fractures of both bone leg includes external stabilization for long period, followed by various soft tissue coverage procedures. Primary interlocking of tibia had been also done with variable results. External fixation for long time without any bone loss often leads to infected nonunion, loss of reduction, pin tract infection and failure of fixation, primary interlocking in compound grade III fractures had shown high medullary infection rate. We managed all cases of compound grade III A/B fractures with primary external fixation, simultaneous wound management using vacuum assisted closure (VAC) followed by early conversion to interlocking within 2 weeks of fixator application. Aim To determine the effectiveness of vacuum assisted closure (VAC) for the early conversion of external fixator to definitive interlocking in open fractures of the both bone leg. Materials and Methods In current study we selected 84 cases of compound grade IIIA/B diaphyseal fractures of both bone leg during period of May 2010 to September 2013. We managed these cases by immediate debridement and application of external fixation followed by repeated debridement, application of vacuum assisted closure (VAC) and conversion to interlocking within two weeks. Results Out of 84 cases union was achieved in 80(95%) of cases with definitive tibial interlocking. Excellent to good result were obtained in 77(91.8%) of cases and fair to poor result seen in rest of 7(8.2%) of cases according to modified Ketenjian’s criteria. 5 out of these 7 poor result group cases were from Compound Grade III B group to start with. Deep infection rate in our series were 7% i.e. total 6 cases and 4 out of these were from compound Grade III B group to start with. Conclusion Vacuum assisted closure (VAC) give a good help for rapid closure of the wound and help in early conversion to definitive intramedullary nailing. Reamed nail could well be used in compound grade IIIA

  12. Computational Fluid Dynamics Analysis of Thrombosis Potential In Left Ventricular Assist Device Drainage Cannulae

    PubMed Central

    Fraser, Katharine H; Zhang, Tao; Taskin, M Ertan; Griffith, Bartley P; Wu, Zhongjun J

    2010-01-01

    Cannulation is necessary when blood is removed from the body, for example in hemodialysis, cardiopulmonary bypass, blood oxygenators, and ventricular assist devices. Artificial blood contacting surfaces are prone to thrombosis, especially in the presence of stagnant or recirculating flow. In this work, computational fluid dynamics was used to investigate the blood flow fields in three clinically available cannulae (Medtronic DLP 12, 16 and 24 F), used as drainage for pediatric circulatory support, and to calculate parameters which may be indicative of thrombosis potential. The results show that using the 24 F cannula below flow rates of about 0.75 l/min produces hemodynamic conditions which may increase the risk of blood clotting within the cannula. No reasons are indicated for not using the 12 or 16 F cannulae with flow rates between 0.25 and 3.0 l/min. PMID:20400890

  13. In vitro and in vivo evaluation of Dideco's paediatric cardiopulmonary circuit for neonates weighing less than five kilograms.

    PubMed

    Thiara, A S; Eggereide, V; Pedersen, T; Lindberg, H; Fiane, A E

    2010-07-01

    The neonate cardiopulmonary bypass (CPB) circuit, including a KIDS D100 oxygenator (The Sorin Group, Mirandola, Italy) and a D130 arterial filter (The Sorin Group), was evaluated in vitro with respect to the removal of free micro gas bubbles. No gas bubbles > 40microm were measured after the arterial filter D130 upon manual introduction of 10 ml of air into the venous line or during the use of vacuum-assisted venous drainage (VAVD). The D130 arterial filter removed 88 % of gas bubbles < 40 microm during manual introduction of air into the venous line; however, only 50 % of gas bubbles < 40 microm were removed during the use of VAVD. The same CPB circuit was evaluated in vivo to compare with another CPB circuit, including a D901 oxygenator (The Sorin Group) and arterial filter D736 (The Sorin Group), in 155 neonates weighing < or =5 kg. The D100 circuit required significantly less priming volume than the D901 circuit. Postoperative haemoglobin was significantly higher, artificial ventilation time was significantly shorter and postoperative bleeding was significantly less in the D100 group. This neonate CPB circuit effectively removed the gas bubbles and required up to 37% less priming volume and, thus, decreased the need for blood transfusion.

  14. Suprapubic tube versus urethral catheter drainage after robot-assisted radical prostatectomy: a systematic review and meta-analysis.

    PubMed

    Jian, Zhongyu; Feng, Shijian; Chen, Yuntian; Wei, Xin; Luo, Deyi; Li, Hong; Wang, Kunjie

    2018-01-05

    Prostate cancer is one of the most common cancers in the elderly population. The standard treatment is radical prostatectomy (RARP). However, urologists do not have consents on the postoperative urine drainage management (suprapubic tube (ST)/ urethral catheter (UC)). Thus, we try to compare ST drainage to UC drainage after robot-assisted radical prostatectomy regarding to comfort, recovery rate and continence using the method of meta-analysis. A systematic search was performed in Dec. 2017 on PubMed, Medline, Embase and Cochrane Library databases. The authors independently reviewed the records to identify studies comparing ST with UC of patients underwent RARP. Meta-analysis was performed using the extracted data from the selected studies. Seven studies, including 3 RCTs, with a total of 946 patients met the inclusion criteria and were included in our meta-analysis. Though there was no significant difference between the ST group and the UC group on postoperative pain (RR1.73, P 0.20), our study showed a significant improvement on bother or discomfort, defined as trouble in hygiene and sleep, caused by catheter when compared two groups at postoperative day (POD) 7 in ST group (RR2.05, P 0.006). There was no significant difference between the ST group and UC group on urinary continence (RR0.98, P 0.74) and emergency department visit (RR0.61, P 0.11). The rates of bladder neck contracture and other complications were very low in both groups. Compared to UC, ST showed a weak advantage. So it might be a good choice to choose ST over RARP.

  15. Video-assisted thoracic surgery repair of subclavian artery injury following central venous catheterization: a new approach

    PubMed Central

    Tam, John Kit Chung; Atasha, Asmat; Tan, Ann Kheng

    2013-01-01

    OBJECTIVES Iatrogenic subclavian artery puncture following central venous catheterization is a rare but potentially fatal complication. There are very few reports in the literature on this condition. We propose the use of video-assisted thoracic surgery (VATS) in the management of these injuries. METHODS The technique of VATS to manage subclavian artery injury was described. We presented the first reported case of successful repair of subclavian artery injury using VATS. RESULTS Using a two-incisional approach for VATS, the haemothorax was rapidly evacuated and the subclavian artery injury was successfully repaired using pledgetted sutures under direct thoracoscopic visualization. The patient had an uneventful postoperative recovery. CONCLUSIONS VATS can be successfully applied to repair subclavian artery injury. The advantages include rapid intrathoracic access, excellent thoracoscopic visualization of the thoracic inlet, and avoidance of the morbidity associated with open thoracotomy. PMID:23518293

  16. Technical specification for vacuum systems

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Khaw, J.

    The vacuum systems at the Stanford Linear Accelerator Center (SLAC) are primarily of all-metal construction and operate at pressures from 10/sup -5/ to 10/sup -11/ Torr. The primary gas loads during operation result from thermal desorption and beam-induced desorption from the vacuum chamber walls. These desorption rates can be extremely high in the case of hydrocarbons and other contaminants. These specifications place a major emphasis on eliminating contamination sources. The specifications and procedures have been written to insure the cleanliness and vacuum integrity of all SLAC vacuum systems, and to assist personnel involved with SLAC vacuum systems in choosing andmore » designing components that are compatible with existing systems and meet the quality and reliability of SLAC vacuum standards. The specification includes requirements on design, procurement, fabrication, chemical cleaning, clean room practices, welding and brazing, helium leak testing, residual gas analyzer testing, bakeout, venting, and pumpdown. Also appended are specifications regarding acceptable vendors, isopropyl alcohol, bakeable valve cleaning procedure, mechanical engineering safety inspection, notes on synchrotron radiation, and specifications of numerous individual components. (LEW)« less

  17. A prospective randomized, controlled trial deems a drainage of 300 ml/day safe before removal of the last chest drain after video-assisted thoracoscopic surgery lobectomy.

    PubMed

    Xie, Hong-Ya; Xu, Kai; Tang, Jin-Xing; Bian, Wen; Ma, Hai-Tao; Zhao, Jun; Ni, Bin

    2015-08-01

    To study the feasible and safe volume threshold for chest tube removal following video-assisted thoracoscopic surgical lobectomy. One hundred and sixty-eight consecutive patients (18 were excluded) who underwent video-assisted thoracoscopic surgery lobectomy or bilobectomy with two incisions between August 2012 and February 2014 were included. Eligible patients were randomized into three groups: Group A (chest tube was removed at a drainage volume of 150 ml/day or less. n = 49); Group B (chest tube was removed when the drainage volume was less than 300 ml/day. n = 50); Group C (chest tube was removed when the drainage volume was less than 450 ml/day. n = 51). The postoperative care of all patients was consistent. The time of extracting the drainage tube, postoperative hospital stay, postoperative visual analogue scale grades, dosage of analgesic, and the incidence of complications and thoracocentesis were measured. Group B and C had a much shorter drainage time and postoperative hospital stay than Group A (P < 0.05). Compared with Group B, Group C had a notably shorter drainage time (P = 0.036). The postoperative hospital stay was not statistically different between Group B and Group C (P > 0.05). The mean dosage of pethidine hydrochloride was 248.9 ± 33.3 mg in Group B and 226.1 ± 32.7 mg in Group C (P > 0.05). The dosage of pethidine hydrochloride of Group A was significantly higher than that of Group B and C (P < 0.05). The total visual analogue scale (VAS) score during the five days showed no statistical differences compared with Group B and Group C (P > 0.05), Group A had a significantly higher total VAS score than Group B and C (P < 0.05). The number of patients who needed thoracentesis in Group C was more than those in Group B and A (P < 0.05). There were no statistically significant differences in the number of patients who needed reinsertion of chest drains among the three groups (P > 0.05). A 300-ml/day volume threshold for chest tube removal after

  18. Surgical repair of an unusual type of supra-cardiac total anomalous pulmonary venous connection to the superior vena cava.

    PubMed

    Perri, Gianluigi; Filippelli, Sergio; Kirk, Richard; Hasan, Asif; Griselli, Massimo

    2012-05-01

    Anomalies of the pulmonary venous drainage vary widely in their anatomic spectrum and clinical presentation. We describe an unusual case of supra-cardiac total anomalous pulmonary venous connection (TAPVC), where the pulmonary veins drained directly in the posterior aspect of proximal right superior vena cava (SVC) through separate ostia. The veins were re-routed with a patch to the left atrium via the secundum atrial septal defect (ASD). The continuity between distal SVC and right atrium was re-established by re-implanting the SVC to the right atrial appendage (Warden Procedure). © 2012 Wiley Periodicals, Inc.

  19. An innovative intermittent-vacuum assisted thermophilic anaerobic digestion process for effective animal manure utilization and treatment.

    PubMed

    Zhang, Renchuan; Anderson, Erik; Addy, Min; Deng, Xiangyuan; Kabir, Fayal; Lu, Qian; Ma, Yiwei; Cheng, Yanling; Liu, Yuhuan; Chen, Paul; Ruan, Roger

    2017-11-01

    Intermittent-vacuum stripping (IVS) was developed as a pretreatment for thermophilic anaerobic digestion (TAD) to improve methanogenesis and hydrolysis activity through preventing free ammonia and hydrogen sulfide (H 2 S) inhibition from liquid swine manure (LSM). Over 98% of ammonia and 38% organic nitrogen were removed in 60min from 55°C to 85°C with vacuum pressure (from 100.63±3.79mmHg to 360.91±7.39mmHg) at initial pH 10.0 by IVS. Thermophilic methanogenesis and hydrolysis activity of pretreated LSM increased 52.25% (from 11.56±1.75% to 17.60±0.49%) in 25days and 40% (from 10days to 6days) in bio-methane potential assay. Over 80% H 2 S and total nitrogen were removed by IVS assistance, while around 70% nitrogen was recycled as ammonium sulfate. Therefore, IVS-TAD combination could be an effective strategy to improve TAD efficiency, whose elution is more easily utilized in algae cultivation and/or hydroponic system. Copyright © 2017 Elsevier Ltd. All rights reserved.

  20. Vacuum assisted birth and risk for cerebral complications in term newborn infants: a population-based cohort study.

    PubMed

    Ekéus, Cecilia; Högberg, Ulf; Norman, Mikael

    2014-01-20

    Few studies have focused on cerebral complications among newborn infants delivered by vacuum extraction (VE). The aim of this study was to determine the risk for intracranial haemorrhage and/or cerebral dysfunction in newborn infants delivered by VE and to compare this risk with that after cesarean section in labour (CS) and spontaneous vaginal delivery, respectively. Data was obtained from Swedish national registers. In a population-based cohort from 1999 to 2010 including all singleton newborn infants delivered at term after onset of labour by VE (n = 87,150), CS (75,216) or spontaneous vaginal delivery (n = 851,347), we compared the odds for neonatal intracranial haemorrhage, traumatic or non-traumatic, convulsions or encephalopathy. Logistic regressions were used to calculate adjusted (for major risk factors and indication) odds ratios (AOR), using spontaneous vaginal delivery as reference group. The rates of traumatic and non-traumatic intracranial hemorrhages were 0.8/10,000 and 3.8/1,000. VE deliveries provided 58% and 31.5% of the traumatic and non-traumatic cases, giving a ten-fold risk [AOR 10.05 (4.67-21.65)] and double risk [AOR 2.23 (1.57-3.16)], respectively. High birth weight and short mother were associated with the highest risks. Infants delivered by CS had no increased risk for intracranial hemorrhages. The risks for convulsions or encephalopathy were similar among infants delivered by VE and CS, exceeding the OR after non-assisted spontaneous vaginal delivery by two-to-three times. Vacuum assisted delivery is associated with increased risk for neonatal intracranial hemorrhages. Although causality could not be established in this observational study, it is important to be aware of the increased risk of intracranial hemorrhages in VE deliveries, particularly in short women and large infants. The results warrant further studies in decision making and conduct of assisted vaginal delivery.

  1. Surgical repair and postoperative course of an infant with infracardiac total anomalous pulmonary venous connection, cor triatriatum sinistrum and transposition of the great arteries.

    PubMed

    Thies, W R; Matthies, W; Minami, K; Pott, U; Meyer, H; Körfer, R

    1990-01-01

    The combination of a d-transposition of the great arteries, cor triatriatum sinistrum and a total anomalous pulmonary venous connection of the infracardiac type is a very rare condition. Up to now, one surgical repair in an adolescent with transposed great arteries and total anomalous pulmonary venous drainage of the supracardiac type has been reported. In this paper, an infant with the above mentioned cardiovascular malformation is presented. The common pulmonary vein drained into the inferior vena cava and was obstructed. There were arborisation abnormalities in both lungs with mild pulmonary hypertension. The infant has been successfully operated upon at the age of 6 months and a weight of 4.5 kg. The membrane within the left atrium was resected, the common pulmonary vein was anastomosed to the left atrium and a Mustard procedure was performed. During the first 6 postoperative weeks, the infant had problems with adaptation. There was both a transient ballooning of the Mustard patch with significant obstruction of the pulmonary venous drainage and a delayed pulmonary recovery. Two months later, the patch was straightened and the child could be discharged from hospital. After 12 months, the child died from an infection of the airways.

  2. Micronised purified flavonoid fraction: a review of its use in chronic venous insufficiency, venous ulcers and haemorrhoids.

    PubMed

    Lyseng-Williamson, Katherine A; Perry, Caroline M

    2003-01-01

    Micronised purified flavonoid fraction (MPFF) [Daflon 500 mg], an oral phlebotropic drug consisting of 90% micronised diosmin and 10% flavonoids expressed as hesperidin, improves venous tone and lymphatic drainage, and reduces capillary hyperpermeability by protecting the microcirculation from inflammatory processes. The absorption of diosmin is improved by its micronisation to particles with a diameter <2 microm. Compared with placebo, MPFF 500 mg twice daily significantly decreased ankle or calf circumference, and improved many symptoms of chronic venous insufficiency (CVI) and plethysmographic parameters in two randomised, double-blind, 2-month studies. Improvement in symptoms was parallelled by an improvement in health-related quality of life in a nonblind, 6-month trial. Significantly more venous leg ulcers

  3. Comparison of intraocular pressure during the application of a liquid patient interface (FEMTO LDV Z8) for femtosecond laser-assisted cataract surgery using two different vacuum levels.

    PubMed

    Ebner, Martina; Mariacher, Siegfried; Januschowski, Kai; Boden, Katrin; Seuthe, Anna-Maria; Szurman, Peter; Boden, Karl Thomas

    2017-08-01

    To evaluate intraocular pressure (IOP) using the application of a novel liquid patient interface for femtosecond laser-assisted cataract surgery with the FEMTO LDV Z8. IOP was evaluated in enucleated porcine eyes prior, during and after the application of the Femto LDV Z8 liquid patient interface (Ziemer Ophthalmic Systems, Switzerland) using intracameral cannulation (n=20), intravitreal cannulation (n=20), rebound tonometry (n=20) and indentation tonometry (n=20). Pressure was assessed prior vacuum, during vacuum (30 s, 1 min, 2 min, 3 min) and after releasing the vacuum (1 min and 2 min). Two groups with different predefined vacuum levels (350 mbar, 420 mbar) were investigated. Mean intracameral pressure (±SD) increased during vacuum application from 20 mm Hg to 52.00 mm Hg (±6.35mm Hg; p=0.005) and 45.18 mmHg (±4.34 mm Hg; p=0.005) for the 420 mbar and the 350 mbar vacuum levels, respectively. Mean intravitreal pressure increased from 20 mm Hg to 25.60 mm Hg (±9.85 mm Hg; p=0.058) and 28.10 mm Hg (±2.54 mm Hg; p=0.059) for the 420 mbar and the 350 mbar vacuum levels, respectively. Pressure values from indentation and rebound tonometry were in between intracameral and intravitreal values. Mean intracameral IOP was 18.1% higher (p=0.019) in the 420 mbar group compared with the 350 mbar group. During vacuum application of the liquid patient interface of the Femto LDV Z8 for femtosecond laser-assisted cataract surgery, IOP values were higher in the anterior chamber compared with the intravitreal pressure measurements. The higher predefined vacuum level (350 mbar vs 420 mbar) resulted in significant higher intracameral IOP. © Article author(s) (or their employer(s) unless otherwise stated in the text of the article) 2017. All rights reserved. No commercial use is permitted unless otherwise expressly granted.

  4. Reduce chest pain using modified silicone fluted drain tube for chest drainage after video-assisted thoracic surgery (VATS) lung resection

    PubMed Central

    Li, Xin; Hu, Bin; Miao, Jinbai

    2016-01-01

    Background The aim of this study was to assess the feasibility, efficacy and safety of a modified silicone fluted drain tube after video-assisted thoracic surgery (VATS) lung resection. Methods The prospective randomized study included 50 patients who underwent VATS lung resection between March 2015 and June 2015. Eligible patients were randomized into two groups: experimental group (using the silicone fluted drain tubes for chest drainage) and control group (using standard drain tubes for chest drainage). The volume and characteristics of drainage, postoperative (PO) pain scores and hospital stay were recorded. All patients received standard care during hospital admission. Results In accordance with the exit criteria, three patients were excluded from study. The remaining 47 patients included in the final analysis were divided into two groups: experiment group (N=24) and control group (N=23). There was no significant difference between the two groups in terms of age, sex, height, weight, clinical diagnosis and type of surgical procedure. There was a trend toward less PO pain in experimental group on postoperative day (POD) 1, with a statistically significant difference. Patients in experimental group had a reduced occurrence of fever [temperature (T) >37.4 °C] compared to the control group. Conclusions The silicone fluted drain tube is feasible and safe and may relieve patient PO pain and reduce occurrence of fever without the added risk of PO complications. PMID:26941976

  5. Reduce chest pain using modified silicone fluted drain tube for chest drainage after video-assisted thoracic surgery (VATS) lung resection.

    PubMed

    Li, Xin; Hu, Bin; Miao, Jinbai; Li, Hui

    2016-02-01

    The aim of this study was to assess the feasibility, efficacy and safety of a modified silicone fluted drain tube after video-assisted thoracic surgery (VATS) lung resection. The prospective randomized study included 50 patients who underwent VATS lung resection between March 2015 and June 2015. Eligible patients were randomized into two groups: experimental group (using the silicone fluted drain tubes for chest drainage) and control group (using standard drain tubes for chest drainage). The volume and characteristics of drainage, postoperative (PO) pain scores and hospital stay were recorded. All patients received standard care during hospital admission. In accordance with the exit criteria, three patients were excluded from study. The remaining 47 patients included in the final analysis were divided into two groups: experiment group (N=24) and control group (N=23). There was no significant difference between the two groups in terms of age, sex, height, weight, clinical diagnosis and type of surgical procedure. There was a trend toward less PO pain in experimental group on postoperative day (POD) 1, with a statistically significant difference. Patients in experimental group had a reduced occurrence of fever [temperature (T) >37.4 °C] compared to the control group. The silicone fluted drain tube is feasible and safe and may relieve patient PO pain and reduce occurrence of fever without the added risk of PO complications.

  6. Pathophysiology of Venous Thromboembolism with Respect to the Anatomical Features of the Deep Veins of Lower Limbs: A Review.

    PubMed

    Ro, Ayako; Kageyama, Norimasa; Mukai, Toshiji

    2017-06-25

    Here the pathophysiology of venous thromboembolism is reviewed with respect to the anatomical features of the deep veins of lower limbs. A thrombus is less likely to form in the thigh veins compared with that in the calf veins; however, clinical symptoms are more likely to appear in the thigh veins owing to vascular occlusion. When a patient is bedridden, thrombosis is more likely to occur in the intramuscular vein, which mainly depends on muscular pumping and the venous valve, rather than in the three crural branches, which mainly depends on the pulsation of the accompanying artery. Thrombi are prone to be generated in the soleal vein compared with those in the gastrocnemius vein because of the vein and muscle structures. A soleal vein thrombosis grows toward the proximal veins along the drainage veins. To prevent a sudden pulmonary thromboembolism-related death in bedridden patients, preventing soleal vein thrombus formation and observing the thrombus proximal propagation via the drainage veins are clinically important. When deep vein thrombosis occurs, avoiding embolization and sequela caused by the thrombus organization is necessary.

  7. Pathophysiology of Venous Thromboembolism with Respect to the Anatomical Features of the Deep Veins of Lower Limbs: A Review

    PubMed Central

    Ro, Ayako; Kageyama, Norimasa; Mukai, Toshiji

    2017-01-01

    Here the pathophysiology of venous thromboembolism is reviewed with respect to the anatomical features of the deep veins of lower limbs. A thrombus is less likely to form in the thigh veins compared with that in the calf veins; however, clinical symptoms are more likely to appear in the thigh veins owing to vascular occlusion. When a patient is bedridden, thrombosis is more likely to occur in the intramuscular vein, which mainly depends on muscular pumping and the venous valve, rather than in the three crural branches, which mainly depends on the pulsation of the accompanying artery. Thrombi are prone to be generated in the soleal vein compared with those in the gastrocnemius vein because of the vein and muscle structures. A soleal vein thrombosis grows toward the proximal veins along the drainage veins. To prevent a sudden pulmonary thromboembolism-related death in bedridden patients, preventing soleal vein thrombus formation and observing the thrombus proximal propagation via the drainage veins are clinically important. When deep vein thrombosis occurs, avoiding embolization and sequela caused by the thrombus organization is necessary. PMID:29034034

  8. Lack of association between venous hemodynamics, venous morphology and the postthrombotic syndrome after upper extremity deep venous thrombosis.

    PubMed

    Czihal, M; Paul, S; Rademacher, A; Bernau, C; Hoffmann, U

    2015-03-01

    To explore the association of the postthrombotic syndrome with venous hemodynamics and morphological abnormalities after upper extremity deep venous thrombosis. Thirty-seven patients with a history of upper extremity deep venous thrombosis treated with anticoagulation alone underwent a single study visit (mean time after diagnosis: 44.4 ± 28.1 months). Presence and severity postthrombotic syndrome were classified according to the modified Villalta score. Venous volume and venous emptying were determined by strain-gauge plethysmography. The arm veins were assessed for postthrombotic abnormalities by ultrasonography. The relationship between postthrombotic syndrome and hemodynamic and morphological sequelae was evaluated using univariate significance tests and Spearman's correlation analysis. Fifteen of 37 patients (40.5%) developed postthrombotic syndrome. Venous volume and venous emptying of the arm affected by upper extremity deep venous thrombosis did not correlate with the Villalta score (rho = 0.17 and 0.19; p = 0.31 and 0.25, respectively). Residual morphological abnormalities, as assessed by ultrasonography, did not differ significantly between patients with and without postthrombotic syndrome (77.3% vs. 86.7%, p = 0.68). Postthrombotic syndrome after upper extremity deep venous thrombosis is not associated with venous hemodynamics or residual morphological abnormalities. © The Author(s) 2013 Reprints and permissions: sagepub.co.uk/journalsPermissions.nav.

  9. Upper Body Venous Compliance Exceeds Lower Body Venous Compliance in Humans

    NASA Technical Reports Server (NTRS)

    Watenpaugh, Donald E.

    1996-01-01

    Human venous compliance hypothetically decreases from upper to lower body as a mechanism for maintenance of the hydrostatic indifference level 'headward' in the body, near the heart. This maintains cardiac filling pressure, and thus cardiac output and cerebral perfusion, during orthostasis. This project entailed four steps. First, acute whole-body tilting was employed to alter human calf and neck venous volumes. Subjects were tilted on a tilt table equipped with a footplate as follows: 90 deg, 53 deg, 30 deg, 12 deg, O deg, -6 deg, -12 deg, -6 deg, O deg, 12 deg, 30 deg, 53 deg, and 90 deg. Tilt angles were held for 30 sec each, with 10 sec transitions between angles. Neck volume increased and calf volume decreased during head-down tilting, and the opposite occurred during head-up tilt. Second, I sought to cross-validate Katkov and Chestukhin's (1980) measurements of human leg and neck venous pressures during whole-body tilting, so that those data could be used with volume data from the present study to calculate calf and neck venous compliance (compliance = (Delta)volume/(Delta)pressure). Direct measurements of venous pressures during postural chances and whole-body tilting confirmed that the local changes in venous pressures seen by Katkov and Chestukhin (1980) are valid. The present data also confirmed that gravitational changes in calf venous pressure substantially exceed those changes in upper body venous pressure. Third, the volume and pressure data above were used to find that human neck venous compliance exceeds calf venous compliance by a factor of 6, thereby upholding the primary hypothesis. Also, calf and neck venous compliance correlated significantly with each other (r(exp 2) = 0.56). Fourth, I wished to determine whether human calf muscle activation during head-up tilt reduces calf venous compliance. Findings from tilting and from supine assessments of relaxed calf venous compliance were similar, indicating that tilt-induced muscle activation is

  10. Acute Spinal Subdural Hematoma after Vertebroplasty: A Case Report Emphasizing the Possible Etiologic Role of Venous Congestion.

    PubMed

    Mattei, Tobias A; Rehman, Azeem A; Dinh, Dzung H

    2015-10-01

    Study Design Case report and literature review. Objective Spinal subdural hematomas are rare events that often progress with severe neurologic deficits. Although there have been several case reports in the literature of spontaneous spinal subdural hematomas in the setting of anticoagulation, antiplatelet therapy, or coagulation disorders, the exact pathophysiology of such phenomena remains obscure. Methods We present the first report of a subdural hematoma after a percutaneous vertebroplasty and provide a comprehensive review on the anatomy of venous drainage of the vertebral bodies with emphasis on the possible effects of venous congestion caused by cement obstruction. Results Because the subdural hematoma occurred in the absence of major cement extravasation to the spinal canal and two levels above the site of the vertebroplasty, we discuss the possible role of venous congestion as the main etiologic factor leading to rupture of the fragile, valveless radiculomedullary veins into the subdural space. Conclusions The reported case supports a possible new pathophysiological scheme for the development of spinal subdural hematoma in which venous congestion plays a pivotal etiologic role. The reported findings suggests that future anatomical and histologic studies investigating the response of the radiculomedullary veins to congestive venous hypertension may shed new light into the pathophysiology of spinal subdural hematomas.

  11. Acute Spinal Subdural Hematoma after Vertebroplasty: A Case Report Emphasizing the Possible Etiologic Role of Venous Congestion

    PubMed Central

    Mattei, Tobias A.; Rehman, Azeem A.; Dinh, Dzung H.

    2015-01-01

    Study Design Case report and literature review. Objective Spinal subdural hematomas are rare events that often progress with severe neurologic deficits. Although there have been several case reports in the literature of spontaneous spinal subdural hematomas in the setting of anticoagulation, antiplatelet therapy, or coagulation disorders, the exact pathophysiology of such phenomena remains obscure. Methods We present the first report of a subdural hematoma after a percutaneous vertebroplasty and provide a comprehensive review on the anatomy of venous drainage of the vertebral bodies with emphasis on the possible effects of venous congestion caused by cement obstruction. Results Because the subdural hematoma occurred in the absence of major cement extravasation to the spinal canal and two levels above the site of the vertebroplasty, we discuss the possible role of venous congestion as the main etiologic factor leading to rupture of the fragile, valveless radiculomedullary veins into the subdural space. Conclusions The reported case supports a possible new pathophysiological scheme for the development of spinal subdural hematoma in which venous congestion plays a pivotal etiologic role. The reported findings suggests that future anatomical and histologic studies investigating the response of the radiculomedullary veins to congestive venous hypertension may shed new light into the pathophysiology of spinal subdural hematomas. PMID:26430602

  12. Computer assisted thermal-vacuum testing

    NASA Technical Reports Server (NTRS)

    Petrie, W.; Mikk, G.

    1977-01-01

    In testing complex systems and components under dynamic thermal-vacuum environments, it is desirable to optimize the environment control sequence in order to reduce test duration and cost. This paper describes an approach where a computer is utilized as part of the test control operation. Real time test data is made available to the computer through time-sharing terminals at appropriate time intervals. A mathematical model of the test article and environmental control equipment is then operated on using the real time data to yield current thermal status, temperature analysis, trend prediction and recommended thermal control setting changes to arrive at the required thermal condition. The data acquisition interface and the time-sharing hook-up to an IBM-370 computer is described along with a typical control program and data demonstrating its use.

  13. The management of vacuum neck drains in head and neck surgery and the comparison of two different practice protocols for drain removal.

    PubMed

    Kasbekar, A V; Davies, F; Upile, N; Ho, M W; Roland, N J

    2016-01-01

    Introduction The management of vacuum neck drains in head and neck surgery is varied. We aimed to improve early drain removal and therefore patient discharge in a safe and effective manner. Methods The postoperative management of head and neck surgical patients with vacuum neck drains was reviewed retrospectively. A new policy was then implemented to measure drainage three times daily (midnight, 6am, midday). The decision for drain removal was based on the most recent drainage period (at <3ml per hour). A further patient cohort was subsequently assessed prospectively. The length of hospital stay was compared between the cohorts. Results The retrospective audit included 51 patients while the prospective audit included 47. The latter saw 16 patients (33%) discharged at least one day earlier than they would have been under the previous policy. No adverse effects were noted from earlier drain removal. Conclusions Measuring drainage volumes three times daily allows for more accurate assessment of wound drainage, and this can lead to earlier removal of neck drains and safe discharge.

  14. Intrapartum translabial ultrasound with pushing used to predict the difficulty in vacuum-assisted delivery of fetuses in non-occiput posterior position.

    PubMed

    Antonio Sainz, José; Borrero, Carlota; Aquise, Adriana; García-Mejido, José Antonio; Gutierrez, Laura; Fernández-Palacín, Ana

    2016-10-01

    Our aim is to evaluate the capacity of intrapartum translabial ultrasound (ITU) with pushing in the prediction of difficulty of fetal extraction in vacuum assisted deliveries. Prospective, observational study performed (2/2015-8/2015) on 75 nulliparous women, ≥37 weeks with singleton pregnancies at full dilatation who had ITU-with-pushing performed, previous to vacuum-placement for fetal extraction. Working on the translabial sagittal-plane, we assessed: Angle-Progression (AoP), Progression-Distance (PD) and Head-Direction (HD); in the axial plane we evaluated: Midline-Angle (MLA) and Head-Perineum-Distance (HPD). Vacuum extractions were classified as easy-difficulty (ED) (≤3 vacuum-pulls), difficult-unsuccessful (DD) (>3 vacuum-pulls). We did not assess occipito-posterior-presentations. Seventy nulliparous were studied (44-ED,26-DD). We observed no differences in obstetric, neonatal or intrapartum characteristics between the two study groups, with the following exceptions: newborn weight (3272 ± 438 g versus 3540 ± 372 g; p = 0.011) and number of vacuum-pulls (1.4-ED-vs-4.4-DD; p < 0.0005). AoP-pushing was 143.9° ± 14.6° in ED and 115.1°± 12.9° in DD (p < 0.0005); Head-Up was 79.5% versus 38.4% (p < 0.0005); PD-Pushing was 42.7 ± 11.3 mm versus 30.4 ± 9.8 mm (p < 0.0005); MLA-Pushing was 27.6°± 26.6° versus 57.5°±26.5°(p=0.025); HPD-Pushing was 40.8 ± 10.0 mm versus 47.4 ± 10.9 mm (p = 0.039). We identified that the presence of an AoP-Pushing > 128° predicts an Easy-Vacuum-Delivery (≤3 Vacuum-Pulls) in  >85% of cases (Sen 80%-FPR 9.3%).

  15. [Effectiveness of vacuum sealing drainage combined with anti-taken skin graft for primary closing of open amputation wound].

    PubMed

    Liao, Qiande; Xu, Jian; Weng, Xiao-Jun; Zhong, Da; Liu, Zhiqin; Wang, Chenggong

    2012-05-01

    To observe the effectiveness of vacuum sealing drainage (VSD) combined with anti-taken skin graft on open amputation wound by comparing with direct anti-taken skin graft. Between March 2005 and June 2010, 60 cases of amputation wounds for limbs open fractures were selected by using the random single-blind method. The amputation wounds were treated with VSD combined with anti-taken skin graft (test group, n = 30) and direct anti-taken skin graft (control group, n = 30). No significant difference was found in age, gender, injury cause, amputation level, defect size, preoperative albumin index, or injury time between 2 groups (P > 0.05). In test group, the redundant stump skin was used to prepare reattached staggered-meshed middle-thickness skin flap by using a drum dermatome dealing after amputation, which was transplanted amputation wounds, and then the skin surface was covered with VSD for continuous negative pressure drainage for 7-10 days. In control group, wounds were covered by anti-taken thickness skin flap directly after amputation, and conventional dress changing was given. To observe the survival condition of the skin graft in test group, the VSD device was removed at 8 days after operation. The skin graft survival rate, wound infection rate, reamputation rate, times of dressing change, and the hospitalization days in test group were significantly better than those in control group [ 90.0% vs. 63.3%, 3.3% vs. 20.0%, 0 vs. 13.3%, (2.0 +/- 0.5) times vs. (8.0 +/- 1.5) times, and (12.0 +/- 2.6) days vs. (18.0 +/- 3.2) days, respectively] (P < 0.05). The patients were followed up 1-3 years with an average of 2 years. At last follow-up, the scar area and grading, and two-point discrimination of wound in test group were better than those in control group, showing significant differences (P < 0.05). No obvious swelling occurred at the residual limbs in 2 groups. The limb pain incidence and the residual limb length were better in test group than those in control

  16. [Caesarean section with vacuum extraction of the head].

    PubMed

    Dimitrov, A; Pavlova, E; Krŭsteva, K; Nikolov, A

    2008-01-01

    The aim of the study is to investigate the benefits and the limits in using the soft cup vacuum extractor on the fetal scalp during the caesarean section. The prospective study includes 19 cases of caesarean sections (group A), with vacuum assisted delivery using the soft cup vacuum extractor on the fetal scalp (diameter 6 cm) and 25 cases (group B) of caesarean sections with usual, manual extraction of the head assisted by fundal compression. All of the patients had undergone a planned caesarean section on term in absence of uterine activity and preserved amniotic membranes. Our results doesn't show differences in the Apgar score on the first and 5-th minute in the newborns of the two groups. The duration of the scalp traction was significantly shorter (30 +/- 4 sec) in comparison to the classical manual extraction (53 +/- 21 sec). The mean duration for applying the vacuum cup was 10 sec and 25 sec for tractions. The total blood loose and total duration of the caesarean sections were shorter than in the control group. The applied traction with the vacuum cup was sufficient for head extraction and there was no need for additional fundal compression. In conclusion we consider that the extraction of the fetal head in high position in caesarean section with vacuum extractor is an easy, non traumatic and rapid method which can put away the need of rough and prolonged fundal compression and its consequences.

  17. Surgical management of anomalous pulmonary venous connection to the superior vena cava - early results

    PubMed Central

    Chandra, Dinesh; Gupta, Anubhav; Nath, Ranjit K.; kazmi, Aamir; Grover, Vijay; Gupta, Vijay K.

    2013-01-01

    Background The anatomical variability in patients with anomalous pulmonary venous connection to superior vena cava presents a surgical challenge. The problem is further compounded by the common occurrence of postoperative complications like arrhythmias and obstruction of the superior vena cava or pulmonary veins. We present our experience of managing this subset using the two patch and Warden's techniques. Patients and methods Between June 2011 and September 2012, 7 patients with APVC to the SVC were operated in our institute. After delineating the anatomy, five of them had a two patch repair and two were managed with Warden's technique. Results There was no in-hospital mortality or early mortality over a mean follow-up of 9.66 ± 3.88 months (range 6–15 months). All the patients on follow-up had unobstructed pulmonary venous and SVC drainage on echocardiography and all of them were in normal sinus rhythm. Conclusions Anomalous pulmonary venous connection to superior vena cava is a challenging subset of patients in whom the surgical management needs to be individualized. The detailed anatomy must be delineated using echocardiography with or without CT angiography before deciding the surgical plan. This entity can be repaired with excellent immediate and early results. However, these patients must be closely followed up for complications like systemic and pulmonary venous obstruction and sinus node dysfunction. PMID:24206880

  18. Partial abnormal drainage of superior and inferior caval veins into the left atrium: two case reports.

    PubMed

    Chessa, Massimo; Carminati, Mario; Cinteză, Eliza Elena; Butera, Gianfranco; Giugno, Luca; Arcidiacono, Carmelo; Piazza, Luciane; Bulescu, Nicolae Cristian; Pome, Giuseppe; Frigiola, Alessandro; Giamberti, Alessandro

    2016-01-01

    Abnormal connection of the right superior caval vein to the left atrium is an uncommon systemic vein drainage anomaly, with only a few cases reported among congenital heart disease (CHD), around 20 cases published in the medical literature. The inferior vena cava connection with the left atrium, also very rare, can appear directly or in heterotaxy. Clinical suspicion arises due to the presence of cyanosis in the absence of other specific clinical signs (without other associated CHD). We present the cases of two children with abnormal superior and inferior systemic venous return. The first case is an abnormal connection of right superior vena cava to the left atrium associated with persistent left superior vena cava draining into the right atrium through the coronary sinus. The second case is an interruption of the inferior vena cava with hemiazygos continuation, drained into the left superior vena cava, which drained into the left atrium. The diagnosis was imagistic - echocardiography and angiography. Surgical treatment solutions vary from one case to another, usually following anatomic correction. Hypoxia accompanied by cyanosis must bring into question the pathology of systemic venous drainage anomaly, after other common causes have been excluded. Surgery is indicated in all cases due to the risk associated with the presence of right-to-left shunt.

  19. Long-term clinical evaluation of a 800-nm long-pulsed diode laser with a large spot size and vacuum-assisted suction for hair removal.

    PubMed

    Ibrahimi, Omar A; Kilmer, Suzanne L

    2012-06-01

    The long-pulsed diode (800-810-nm) laser is one of the most commonly used and effective lasers for hair removal. Limitations of currently available devices include a small treatment spot size, treatment-associated pain, and the need for skin cooling. To evaluate the long-term hair reduction capabilities of a long-pulsed diode laser with a large spot size and vacuum assisted suction. Thirty-five subjects were enrolled in a prospective, self-controlled, single-center study of axillary hair removal. The study consisted of three treatments using a long-pulsed diode laser with a large spot size and vacuum-assisted suction at 4- to 6-week intervals with follow-up visits 6 and 15 months after the last treatment. Hair clearance was quantified using macro hair-count photographs taken at baseline and at 6- and 15-month follow-up visits. Changes in hair thickness and color, levels of treatment-associated pain, and adverse events were additional study endpoints. There was statistically significant hair clearance at the 6 (54%) and 15-month (42%) follow-up visits. Remaining hairs were thinner and lighter at the 15-month follow-up visit, and the majority of subjects reported feeling up to mild to moderate pain during treatment without the use of pretreatment anesthesia or skin cooling. A long-pulsed diode laser with a large spot size and vacuum-assisted suction is safe and effective for long-term hair removal. This is the largest prospective study to evaluate long-term hair removal and the first to quantify decreases in hair thickness and darkness with treatment. © 2012 by the American Society for Dermatologic Surgery, Inc. Published by Wiley Periodicals, Inc.

  20. A vacuum flash-assisted solution process for high-efficiency large-area perovskite solar cells

    NASA Astrophysics Data System (ADS)

    Li, Xiong; Bi, Dongqin; Yi, Chenyi; Décoppet, Jean-David; Luo, Jingshan; Zakeeruddin, Shaik Mohammed; Hagfeldt, Anders; Grätzel, Michael

    2016-07-01

    Metal halide perovskite solar cells (PSCs) currently attract enormous research interest because of their high solar-to-electric power conversion efficiency (PCE) and low fabrication costs, but their practical development is hampered by difficulties in achieving high performance with large-size devices. We devised a simple vacuum flash-assisted solution processing method to obtain shiny, smooth, crystalline perovskite films of high electronic quality over large areas. This enabled us to fabricate solar cells with an aperture area exceeding 1 square centimeter, a maximum efficiency of 20.5%, and a certified PCE of 19.6%. By contrast, the best certified PCE to date is 15.6% for PSCs of similar size. We demonstrate that the reproducibility of the method is excellent and that the cells show virtually no hysteresis. Our approach enables the realization of highly efficient large-area PSCs for practical deployment.

  1. Venous thromboembolism after major venous injuries: Competing priorities.

    PubMed

    Frank, Brian; Maher, Zoё; Hazelton, Joshua P; Resnick, Shelby; Dauer, Elizabeth; Goldenberg, Anna; Lubitz, Andrea L; Smith, Brian P; Saillant, Noelle N; Reilly, Patrick M; Seamon, Mark J

    2017-12-01

    Venous thromboembolism (VTE) after major vascular injury (MVI) is particularly challenging because the competing risk of thrombosis and embolization after direct vessel injury must be balanced with risk of bleeding after surgical repair. We hypothesized that venous injuries, repair type, and intraoperative anticoagulation would influence VTE formation after MVI. A multi-institution, retrospective cohort study of consecutive MVI patients was conducted at three urban, Level I centers (2005-2013). Patients with MVI of the neck, torso, or proximal extremities (to elbows/knees) were included. Our primary study endpoint was the development of VTE (DVT or pulmonary embolism [PE]). The 435 major vascular injury patients were primarily young (27 years) men (89%) with penetrating (84%) injuries. When patients with (n = 108) and without (n = 327) VTE were compared, we observed no difference in age, mechanism, extremity injury, tourniquet use, orthopedic and spine injuries, damage control, local heparinized saline, or vascular surgery consultation (all p > 0.05). VTE patients had greater Injury Severity Score (ISS) (17 vs. 12), shock indices (1 vs. 0.9), and more torso (58% vs. 35%) and venous (73% vs. 48%) injuries, but less often received systemic intraoperative anticoagulation (39% vs. 53%) or postoperative enoxaparin (47% vs. 61%) prophylaxis (all p < 0.05). After controlling for ISS, hemodynamics, injured vessel, intraoperative anticoagulation, and postoperative prophylaxis, multivariable analysis revealed venous injury was independently predictive of VTE (odds ratio, 2.7; p = 0.002). Multivariable analysis of the venous injuries subset (n = 237) then determined that only delay in starting VTE chemoprophylaxis (odds ratio, 1.3/day; p = 0.013) independently predicted VTE after controlling for ISS, hemodynamics, injured vessel, surgical subspecialty, intraoperative anticoagulation, and postoperative prophylaxis. Overall, 3.4% of venous injury patients developed PE, but PE

  2. Sequential therapy with "vacuum sealing drainage-artificial dermis implantation-thin partial thickness skin grafting" for deep and infected wound surfaces in children.

    PubMed

    Yuan, X-G; Zhang, X; Fu, Y-X; Tian, X-F; Liu, Y; Xiao, J; Li, T-W; Qiu, L

    2016-05-01

    To evaluate the efficacy of a "vacuum sealing drainage (VSD) - artificial dermis implantation (ADI) - thin partial thickness skin grafting (TSG)" sequential therapy for deep and infected wounds in children. Fifty-three pediatric patients with deep and infected wounds were treated with sequential VSD-ADI-TSG therapy. The efficacy of this treatment was compared with that of the surgical debridement-change dressings-thin partial thickness skin grafting previously performed on 20 patients. Survival of tissue grafts, color and flexibility, subcutaneous fullness and scar formation of the graft site were examined and compared. The sequential therapy combined the advantages of the VSD treatment, in reducing tissue necrosis and infection on the wound surfaces and promoting the growth of granulation tissue, with the enhancement of grafting by artificial dermis. Compared with the 20 controls, skin grafted on the artificial dermis was more smooth and glossy, while the textures of the region were more elastic, and the scars were significantly lighter in Vancouver scale. The sequential VSD-ADI-TSG therapy is a simple and effective treatment for children with deep and infected wounds. IV. Copyright © 2016. Published by Elsevier Masson SAS.

  3. High risk of fistula formation in vacuum-assisted closure therapy in patients with open abdomen due to secondary peritonitis-a retrospective analysis.

    PubMed

    Mintziras, Ioannis; Miligkos, Michael; Bartsch, Detlef Klaus

    2016-08-01

    The aim of this study was to evaluate the efficacy of vacuum-assisted closure therapy in patients with open abdomen due to secondary peritonitis and to identify possible risk factors of fistula formation. The hospital OPS-database (time period 2005-2014) was searched to identify patients treated with an open abdomen due to secondary peritonitis, who underwent vacuum-assisted closure therapy. Medical records were retrospectively analyzed for patients' characteristics, cause of peritonitis, duration of vacuum therapy, number of relaparotomies, fascial closure rates, and risk factors of fistula formation. Forty-three patients (19 male, 24 female) with a median age of 65 years (range 24-90 years) were identified. The major cause of secondary peritonitis was anastomotic leakage after intestinal anastomosis or bowel perforation, the median APACHE II score was 11. Median duration of VAC treatment was 12 days (range 3-88 days). Twenty of 43 (47 %) patients died from septic complications. Delayed fascial closure was obtained by suturing in 20 of 43 patients (47 %). Overall 16 of 43 (37 %) patients developed enteroatmospheric fistulas. Re-explorations after starting VAC treatment and duration of VAC therapy were significantly associated with the occurrence of enteroatmospheric fistulas (p < 0.001). ROC curve analysis determined the optimal duration of VAC therapy to reduce the risk of fistula formation at 13 days. Long-term VAC treatment of patients with an open abdomen due to secondary peritonitis results in a relatively low fascial closure rate and a high risk of fistula formation.

  4. The effect of drainage tube on bleeding and prognosis after total knee arthroplasty: a prospective cohort study.

    PubMed

    Liu, Xiao-Han; Fu, Pei-Liang; Wang, Shi-Ying; Yang, Ya-Juan; Lu, Gen-Di

    2014-04-23

    To evaluate the effect of drainage tube on prognosis after total knee arthroplasty (TKA) and explore an effective treatment with favorable prognosis. In a prospective study, 18 patients with TKA for the first time were included and randomly divided into three groups, group A (no placement of drainage tube), group B (negative pressure drainage), and group C (4 h clamping drainage). Intraoperative and postoperative blood loss, operation time, and the drainage volume were recorded and analyzed. Arthrocele, ecchymosis, and range of motion (ROM) were examined postoperatively. The degree of pain was scored by Visual Analog Scale (VAS) after 6, 12, and 24 h of operation. The complications were examined and HSS (hospital for special surgery) knee score was taken during the follow-up period. There was no significant difference in operation time, total blood loss, intraoperative blood loss, and VAS score among three groups. Meanwhile, the hidden blood loss in group B was significantly decreased compared with group A (P = 0.0015). The postoperative drainage volume of group B was significantly increased compared with group C (P = 0.0002). No drainage increased the rate of arthrocele and ecchymosis. Compared with group A, ROM after 3 days of operation in groups B and C was significantly increased (P = 0.0357, P = 0.0372, respectively). During follow-up study, no deep infection or deep venous thrombosis was found. After TKA, early clamping of the drainage tube reduced the bleeding loss without adverse effect on prognosis, which might be useful for clinical application in future.

  5. Development of Needle Insertion Manipulator for Central Venous Catheterization

    NASA Astrophysics Data System (ADS)

    Kobayashi, Yo; Hong, Jaesung; Hamano, Ryutaro; Hashizume, Makoto; Okada, Kaoru; Fujie, Masakatsu G.

    Central venous catheterization is a procedure, which a doctor insert a catheter into the patient’s vein for transfusion. Since there are risks of bleeding from arterial puncture or pneumothorax from pleural puncture. Physicians are strictly required to make needle reach up into the vein and to stop the needle in the middle of vein. We proposed a robot system for assisting the venous puncture, which can relieve the difficulties in conventional procedure, and the risks of complication. This paper reports the design structuring and experimental results of needle insertion manipulator. First, we investigated the relationship between insertion force and angle into the vein. The results indicated that the judgment of perforation using the reaction force is possible in case where the needling angle is from 10 to 20 degree. The experiment to evaluate accuracy of the robot also revealed that it has beyond 0.5 mm accuracy. We also evaluated the positioning accuracy in the ultrasound images. The results displays that the accuracy is beyond 1.0 mm and it has enough for venous puncture. We also carried out the venous puncture experiment to the phantom and confirm our manipulator realized to make needle reach up into the vein.

  6. On the Resolvability of Steam Assisted Gravity Drainage Reservoirs Using Time-Lapse Gravity Gradiometry

    NASA Astrophysics Data System (ADS)

    Elliott, E. Judith; Braun, Alexander

    2017-11-01

    Unconventional heavy oil resource plays are important contributors to oil and gas production, as well as controversial for posing environmental hazards. Monitoring those reservoirs before, during, and after operations would assist both the optimization of economic benefits and the mitigation of potential environmental hazards. This study investigates how gravity gradiometry using superconducting gravimeters could resolve depletion areas in steam assisted gravity drainage (SAGD) reservoirs. This is achieved through modelling of a SAGD reservoir at 1.25 and 5 years of operation. Specifically, the density change structure identified from geological, petrological, and seismic observations is forward modelled for gravity and gradients. Three main parameters have an impact on the resolvability of bitumen depletion volumes and are varied through a suitable parameter space: well pair separation, depth to the well pairs, and survey grid sampling. The results include a resolvability matrix, which identifies reservoirs that could benefit from time-lapse gravity gradiometry monitoring. After 1.25 years of operation, during the rising phase, the resolvable maximum reservoir depth ranges between the surface and 230 m, considering a well pair separation between 80 and 200 m. After 5 years of production, during the spreading phase, the resolvability of depletion volumes around single well pairs is greatly compromised as the depletion volume is closer to the surface, which translates to a larger portion of the gravity signal. The modelled resolvability matrices were derived from visual inspection and spectral analysis of the gravity gradient signatures and can be used to assess the applicability of time-lapse gradiometry to monitor reservoir density changes.

  7. Management of Arteriovenous Malformations Associated with Developmental Venous Anomalies: A Literature Review and Report of 2 Cases.

    PubMed

    Zhang, Michael; Connolly, Ian D; Teo, Mario K; Yang, George; Dodd, Robert; Marks, Michael; Zuccarello, Mario; Steinberg, Gary K

    2017-10-01

    Classification of cerebrovascular malformations has revealed intermediary lesions that warrant further review owing to their unusual presentation and management. We present 2 cases of arteriovenous malformation (AVM) associated with a developmental venous anomaly (DVA), and discuss the efficacy of previously published management strategies. Two cases of AVMs associated with DVA were identified, and a literature search for published cases between 1980 and 2016 was conducted. Patient demographic data and clinical features were documented. In case 1, a 29-year-old female presenting with parenchymal hemorrhage and left homonymous hemianopia was found to have a right parieto-occipital AVM fed from the anterior cerebral, middle cerebral, and posterior cerebral arteries, with major venous drainage to the superior sagittal sinus. In case 2, imaging in a 34-year-old female evaluated for night tremors and incontinence revealed a left parietal AVM with venous drainage to the superior sagittal sinus. Including our 2 cases, 22 cases of coexisting AVMs and DVAs have been reported in the literature. At presentation, 68% had radiographic evidence of hemorrhage. Stereotactic radiosurgery was performed in 7 cases, embolization in 6 cases, surgical resection in 4 cases, and multimodal therapy in 5 cases. Radiography at follow-up demonstrated successful AVM obliteration in 67% of cases (12 of 18). Patients with coexisting AVMs and DVAs tend to have a hemorrhagic presentation. Contrary to traditional AVM management, in these cases it is important to preserve the draining vein via the DVA to ensure a safe, sustained circulatory outflow of the associated brain parenchyma while achieving safe AVM obliteration. Copyright © 2017 Elsevier Inc. All rights reserved.

  8. Tuberculosis of the arterio-venous graft in a renal transplant recipient.

    PubMed

    Alalawi, Fakhriya; Alhadari, Amna; Railey, M J; Alrukhaimi, Mona

    2012-09-01

    A 44-year-old Pakistani lady with end-stage renal disease secondary to rapidly proliferative glomerulonephritis underwent successful renal transplantation. Three years later, she was referred to the surgeon with an abscess in the axillary region at the site of a previous arterio-venous (AV) graft. She underwent repeated incision and drainage of the abscess, which was constantly recurring. Nine months later, she presented with a tender swelling at the site of the AV graft with purulent discharge. The graft was removed; culture and histology confirmed the presence of tuberculosis (TB). This patient presents a rare case of TB infection in the AV graft.

  9. Transbronchial drainage using endobronchial ultrasonography with guide sheath for lung abscess

    PubMed Central

    Yaguchi, Daizo; Ichikawa, Motoshi; Inoue, Noriko; Kobayashi, Daisuke; Shizu, Masato; Imai, Naoyuki

    2018-01-01

    Abstract Rationale: Lung abscess was previously treated surgically, but is now mainly treated with antibiotics and ideally with direct drainage, although postural drainage canalso be used. Patient concerns: A chest abnormal shadow was detected in an 82-year-old man and he was referred to our department in November 2017. On chest computed tomography (CT), a low-density mass shadow was present in the left S8 segment. Lung abscess and lung cancer were considered as differential diagnoses, and treatment with sulbactam sodium/ampicillin sodium (SBT/ABPC) was first initiated for lung abscess. The etiologic agent could not be identified by sputum examination, and the abscess shadow remained. Diagnoses: Lung abscess. Interventions: Endobronchial ultrasonography with a guide sheath (EBUS-GS)-guided bronchoscopy was performed on hospital day 21 to diagnose the lesion, identify the etiologic agent if the lesion was a lung abscess, and attempt drainage. Vacuum aspiration performed in the guide sheath after the probe was placed within the lesion produced 4-5 ml of gray turbid pus, and the abscess was judged to have been drained. Outcomes: A subsequent pathological examination did not detect malignant cells. Klebsiella pneumoniae, Prevotella spp. was identified as the etiologic agent in bacteriological tests. Antibiotics were changed based on sensitivity test results, and drainage was similarly performed on hospital day 28. The shadow gradually improved and disappeared. Therefore, this procedure and treatment led to identification of the etiologic agent and helped with cure of the disease. Lessons: Based on the basic principle of treatment for abscess using as much drainage as possible, EBUS-GS-guided transbronchial drainage may be considered to be a “new procedure” for lung abscess. PMID:29768382

  10. [Superior vena cava syndrome unrelated to central venous catheter in a patient on chronic hemodialysis].

    PubMed

    Veronesi, Marco; Mancini, Elena; Salvati, Filippo; Santoro, Antonio

    2011-01-01

    A 67-year-old woman with end-stage renal disease (polycystic kidney disease) who had been on dialysis for 10 years came to our department for a second opinion about upper left arm edema homolateral to the arteriovenous fistula (AVF). Because of the suspicion of venous stenosis she had already been submitted to angiographic examination of the AVF which, however, did not show any occlusive process. In addition to the kidney problem, the clinical history included dilated cardiomyopathy, and 2 years earlier a biventricular implantable cardioverter defibrillator (ICD) had been placed. The patient had never had a central venous catheter (CVC). She presented a typical superior vena cava syndrome picture with arm, neck and hemifacial edema and superficial cutaneous venous reticulum. The venous pressure during extracoroporeal circulation was high and blood recirculation was documented. Angio-CT was performed to look for a compressive process in the chest, but this was excluded. We then performed a new trans-AVF angiography to study extensively the axillary-subclavian-superior vena cava district. At first, no stenosis or thrombosis was observed, but the presence of ICD and its leads (left-sided implanted) in the anonymous vein created obstacles to diagnosis. Repeated injections of contrast medium and focusing imaging on the leads route allowed us to highlight a venous stenosis in the anonymous vein. Transluminal angioplasty was successfully carried out during the same procedure. 1) In hemodialysis patients the appearance of signs of intrathoracic vein drainage obstacles is not always associated with previous CVC implantation; 2) in the hemodialysis patient, any device (PM, ICD) should be implanted contralaterally to the fistula arm in order to avoid the risk that a venous stenosis may cause AVF dysfunction.

  11. The effect of drainage tube on bleeding and prognosis after total knee arthroplasty: a prospective cohort study

    PubMed Central

    2014-01-01

    Background To evaluate the effect of drainage tube on prognosis after total knee arthroplasty (TKA) and explore an effective treatment with favorable prognosis. Methods In a prospective study, 18 patients with TKA for the first time were included and randomly divided into three groups, group A (no placement of drainage tube), group B (negative pressure drainage), and group C (4 h clamping drainage). Intraoperative and postoperative blood loss, operation time, and the drainage volume were recorded and analyzed. Arthrocele, ecchymosis, and range of motion (ROM) were examined postoperatively. The degree of pain was scored by Visual Analog Scale (VAS) after 6, 12, and 24 h of operation. The complications were examined and HSS (hospital for special surgery) knee score was taken during the follow-up period. Results There was no significant difference in operation time, total blood loss, intraoperative blood loss, and VAS score among three groups. Meanwhile, the hidden blood loss in group B was significantly decreased compared with group A (P = 0.0015). The postoperative drainage volume of group B was significantly increased compared with group C (P = 0.0002). No drainage increased the rate of arthrocele and ecchymosis. Compared with group A, ROM after 3 days of operation in groups B and C was significantly increased (P = 0.0357, P = 0.0372, respectively). During follow-up study, no deep infection or deep venous thrombosis was found. Conclusion After TKA, early clamping of the drainage tube reduced the bleeding loss without adverse effect on prognosis, which might be useful for clinical application in future. PMID:24755244

  12. Quantifying saphenous recirculation in patients with primary lower extremity venous reflux.

    PubMed

    Lattimer, Christopher R; Azzam, Mustapha; Kalodiki, Evi; Geroulakos, George

    2016-04-01

    The great saphenous vein (GSV) in patients with superficial venous insufficiency might act as a beneficial conduit for antegrade venous drainage and also as a harmful conduit for promotion of reflux and/or recirculation and subsequent skin changes. The aim of this study was to measure the antegrade and retrograde GSV volume displacements during calf compression and release maneuvers. This was used to quantify harm over benefit with a recirculation index (RCI). Sixteen legs (nine right) from 16 patients (nine male) with primary superficial venous insufficiency were scanned standing with duplex ultrasound, at the upper thigh GSV, 10 cm below the sapheno-femoral junction. The clinical, etiological, anatomical, pathophysiological class was C2 = 3, C3 = 2, C4a = 6, C4b = 4, C5 = 1. The median age (range), venous clinical severity score, and refluxing GSV diameter were 63 (21-79) years, 8 (4-16), and 7 (5-10) mm, respectively. A manual calf compression and release (MCCR) maneuver was performed once, and a cyclical calf compression and release (CCCR) three times for repeatability. With the CCCR maneuver, the calf-cuff and inflation-deflation pump provided a cyclical compression pressure of 120 mm Hg (3 seconds) with a release time of 16.4 seconds to standardize venous refilling time. The results are expressed as median [interquartile range]. The CCCR compared with the MCCR resulted in longer reflux duration (16.4 [8.2-16.4] seconds vs 5.7 [3.7-6.8] seconds; P < .0005), higher time-averaged mean velocities in reflux (23.5 [14.9-27.9] cm/s vs 14.1 [9-17.6] cm/s; P < .0005) and greater reflux volume displacements (81.7 [38.8-152.8] mL vs 27.3 [16.4-53.4] mL; P < .0005). There were significant correlations between increasing antegrade volume measurements and increasing reflux volume measurements irrespective of whether CCCR, (r = 0.841; P < .0005) or MCCR (r = 0.762; P = .001) was used. This implies that the displaced antegrade volume might have a causal effect on the

  13. Contrast radiographic study of venous drainage of the corpus cavernosum and the corpus spongiosum of the cat penis.

    PubMed

    Amiri, Ali Akbar; Gilanpour, Hassan; Veshkini, Abbas

    2014-01-01

    The aim of this study was to determine the drainage routes of the corpus cvernosum penis and the corpus spongiosum penis in the cat using contrast cavernosography. Five male cats, 1.5-2.5 years old, weighing between 4.5 and 5.5 kg were investigated. The cats were anesthetized and the root and the proximal part of the penis were exposed by an incision on the perineum reaching the scrotum. Each cat was radiographed in lateral and dorsal recumbency before and during injection of contrast medium into the erectile bodies. The corpus spongiosum penis was injected at the bulb of the penis and the corpus cavernosum penis at the root. Injection of contrast media into the cavernous bodies showed that both the external and internal iliac veins drain the erectile bodies into the caudal vena cava. Drainage from the corpus spongiosum penis was from the bulb for the proximal part and from the glans for the distal part. The corpus cavernosum penis was drained only proximally, from the crura. There was a network of veins above the pelvic symphysis and the drainage of erectile bodies where through various routes into the internal and external iliac veins.

  14. MDCT Venography Evaluation of a Rare Collateral Vein Draining from the Left Subclavian Vein to the Great Cardiac Vein

    PubMed Central

    Abchee, Antoine; Saade, Charbel; Al-Mohiy, Hussain; El-Merhi, Fadi

    2014-01-01

    Congenital vascular anomalies of the venous drainage in the chest affect both cardiac and non-cardiac structures. Collateral venous drainage from the left subclavian vein to the great cardiac vein is a rare venous drainage pattern. These anomalies present a diagnostic challenge. Multi-detector computed tomography (MDCT) is useful in the diagnosis and treatment planning of these clinically complex disorders. We present a case report of an 18-year-old Caucasian male who came to our institute for evaluation of venous drainage patterns to the heart. We describe the contrast technique of bilateral dual injection MDCT venography and the imaging features of the venous drainage patterns to the heart. PMID:25379351

  15. MDCT Venography Evaluation of a Rare Collateral Vein Draining from the Left Subclavian Vein to the Great Cardiac Vein.

    PubMed

    Abchee, Antoine; Saade, Charbel; Al-Mohiy, Hussain; El-Merhi, Fadi

    2014-01-01

    Congenital vascular anomalies of the venous drainage in the chest affect both cardiac and non-cardiac structures. Collateral venous drainage from the left subclavian vein to the great cardiac vein is a rare venous drainage pattern. These anomalies present a diagnostic challenge. Multi-detector computed tomography (MDCT) is useful in the diagnosis and treatment planning of these clinically complex disorders. We present a case report of an 18-year-old Caucasian male who came to our institute for evaluation of venous drainage patterns to the heart. We describe the contrast technique of bilateral dual injection MDCT venography and the imaging features of the venous drainage patterns to the heart.

  16. A New Procedure for Wrapped-Negative Pressure Wound Therapy for Congestion After Arterialized Venous Flap Surgery

    PubMed Central

    Niimi, Yosuke; Mori, Satoko; Takeuchi, Masaki

    2017-01-01

    Negative pressure wound therapy (NPWT) is a method for treating wound. However, there are no case reports using NPWT for treating congestion after arterialized venous flap. Therefore, this study reported favorable outcomes after using a single-use NPWT system for managing congestion. A 39-year-old man had his index finger caught by a press machine. The finger had a soft tissue defect at the ventral part. An arterialized venous flap taken from the right forearm was transplanted. Perfusion of the flap was favorable, but on postoperative day 5, congestion and the edema of the flap were found. Then, NPWT was initiated. The congestion and edema in the flap were improved without complications such as flap necrosis and wound infection. At 4 months postoperatively, the morphology of the finger was favorable. In this study, NPWT was speculated to force the deeper blood vessels within the flap to dilate with inducing drainage and the simultaneous reduction in excess blood flow to the cortical layer, resulting in the improvement of congestion. Negative pressure wound therapy was used for treating congestion after the transplantation of arterialized venous flap, and the wound was favorably managed. PMID:29270041

  17. Method and apparatus for performing in-situ vacuum-assisted metal to glass sealing

    DOEpatents

    Kramer, D.P.; Massey, R.T.

    1985-07-18

    A method and apparatus for assembling and fusing glass to metal in a glass-metal electrical component is disclosed. The component includes a metallic shell formed with upper and lower cylindrical recesses connected together by longitudinal passages, a pair of metal rings and plural metal pins assembled to define electrical feed-throughs. The component parts are assembled on a fixture having a sleeve-like projection and a central mounting projection establishing concentric nesting surfaces to which the metal rings are slip-fitted in concentric alignment with each other spaced from sidewalls of the lower recess. The pins are in electrical contact with the metal rings. A glass pre-form is seated within the upper recess. The assembled structure is heated to a temperature sufficient to melt the glass pre-form which flows under gravity through the passages into the lower recess to provide an insulative seal between the metal parts. The gravity flow of glass is assisted by applying vacuum to the lower recess, ensuring that all spaces between the metal parts are filled with sealing glass without formation of bubbles.

  18. Method and apparatus for performing in-situ vacuum-assisted metal to glass sealing

    DOEpatents

    Kramer, Daniel P.; Massey, Richard T.

    1986-01-01

    A method and apparatus for assembling and fusing glass to metal in a glass-metal electrical component is disclosed. The component includes a metallic shell formed with upper and lower cylindrical recesses connected together by longitudinal passages, a pair of metal rings and plural metal pins assembled to define electrical feed-throughs. The component parts are assembled on a fixture having a sleeve-like projection and a central mounting projection establishing concentric nesting surfaces to which the metal rings are slip-fitted in concentric alignment with each other spaced from sidewalls of the lower recess. The pins are in electrical contact with the metal rings. A glass pre-form is seated within the upper recess. The assembled structure is heated to a temperature sufficient to melt the glass pre-form which flows under gravity through the passages into the lower recess to provide an insulative seal between the metal parts. The gravity flow of glass is assisted by applying vacuum to the lower recess, ensuring that all spaces between the metal parts are filled with sealing glass without formation of bubbles.

  19. [Effects of vacuum sealing drainage combined with irrigation of oxygen loaded fluid on wounds of pa- tients with chronic venous leg ulcers].

    PubMed

    Wen, Huangding; Li, Zhiqing; Zhang, Meiguang; Wang, Jiahan; Wang, Guifang; Wu, Qi; Tong, Sen

    2015-04-01

    To evaluate the therapeutic effects of VSD combined with irrigation of oxygen loaded fluid on the growth of granulation tissue and macrophage polarization in chronic venous leg ulcers. Thiry-four patients with chronic venous leg ulcers hospitalized in our department from December 2010 to July 2014 were divided into VSD group ( A, n = 11) , VSD + irrigation group ( B, n = 11) , and VSD + oxygen loaded fluid irrigation group ( C, n = 12) according to the random number table. After admissian, debridement was performed, and granulation tissue in the center of the wound was harvested during the operation. After dehridement, the patients in group A were treated with VSD only (negative pressure from -30 to -25 kPa, the same below) ; the patients in group B were treated with VSD combining irrigation of normal saline; the patients in group C were treated with VSD combining normal saline loaded with oxygen irrigation (flow of 1 L/min) . On post treatment day (PTD) 7, the VSD devices were removed. Cross observation was conducted before debridement and on PTD 7. On PTD 7, the granulation tissue in the center of the wound was harvested for histopathological observation with HE staining and Masson staining, following calculation of granulation tissue coverage rate. After debridement but before the negative pressure therapy (hereinafter referred to as before treatment) and on PTD 7, partial pressure of oxygen of the skin around the wound was measured by transcutaneous tissue oxygen tension survey meter. On PTD 7, expression of vascular endothelial growth factor (VECF) was determined with immunohistochemistry. Before treatment and on PTD 7, cells with double positive expressions of induced nitric oxide synthase plus CD68 ( type I macro- phage) and arginase 1 plus CD68 ( type II macrophage) were observed with immunofluorescence staining and quantified. Data were processed with Fisher's exact test, one-way analysis of variance, covariance analysis, paired test, and LSD test. (1) The

  20. Application of ionic liquids in vacuum microwave-assisted extraction followed by macroporous resin isolation of three flavonoids rutin, hyperoside and hesperidin from Sorbus tianschanica leaves.

    PubMed

    Gu, Huiyan; Chen, Fengli; Zhang, Qiang; Zang, Jing

    2016-03-01

    Rutin, hyperoside and hesperidin were effectively extracted from Sorbus tianschanica leaves by an ionic liquid vacuum microwave-assisted method. A series of ionic liquids with various anions and alkyl chain length of the cations were studied and the extraction was performed in [C6mim][BF4] aqueous solution. After optimization by a factorial design and response surface methodology, total extraction yield of 2.37mg/g with an error of 0.12mg/g (0.71±0.04mg/g, 1.18±0.06mg/g and 0.48±0.02 for rutin, hyperoside and hesperidin, respectively) was achieved under -0.08MPa for vacuum, 19min and 420W for microwave irradiation time and power, and 15mL/g for liquid-solid ratio. The proposed method here is more efficient and needs a shorter extraction time for rutin, hyperoside and hesperidin from S. tianschanica leaves than reference extraction techniques. In stability studies performed with standard rutin, hyperoside and hesperidin, the target analytes were stable under the optimum conditions. The proposed method had a high reproducibility and precision. In addition, separation of rutin, hyperoside and hesperidin from [C6mim][BF4] extraction solution was completed effectively by AB-8 macroporous resin adsorption and desorption process. Ionic liquid vacuum microwave-assisted extraction is a simple, rapid and efficient sample extraction technique. Copyright © 2016 Elsevier B.V. All rights reserved.

  1. Venous Ulcers

    PubMed Central

    Caprini, J.A.; Partsch, H.; Simman, R.

    2013-01-01

    Venous leg ulcers are the most frequent form of wounds seen in patients. This article presents an overview on some practical aspects concerning diagnosis, differential diagnosis and treatment. Duplex ultrasound investigations are essential to ascertain the diagnosis of the underlying venous pathology and to treat venous refluxes. Differential diagnosis includes mainly other vascular lesions (arterial, microcirculatory causes), hematologic and metabolic diseases, trauma, infection, malignancies. Patients with superficial venous incompetence may benefit from endovenous or surgical reflux abolition diagnosed by Duplex ultrasound. The most important basic component of the management is compression therapy, for which we prefer materials with low elasticity applied with high initial pressure (short-stretch bandages and Velcro-strap devices). Local treatment should be simple, absorbing and not sticky dressings keeping adequate moisture balance after debridement of necrotic tissue and biofilms are preferred. After the ulcer is healed compression therapy should be continued in order to prevent recurrence. PMID:26236636

  2. Intraoperative Tumoral Bleeding of Hypervascular Medulloblastoma after Ventricular Drainage: A Case Report.

    PubMed

    Ryu, Han-Seung; Jung, Tae-Young; Han, Moon-Soo; Kim, Seul-Ki; Lee, Kyung-Hwa

    2017-01-01

    We report a rare case of intraoperative tumoral bleeding of a hypervascular medulloblastoma. A 12-year-old girl presented with dizziness and nausea. Brain magnetic resonance (MR) images revealed an approximately 4.2-cm enhanced mass on the cerebellar vermis associated with mild perilesional edema and increased cerebral blood volume. Angiography showed tumoral staining and developed occipital and circular dural sinuses in the venous phase. A suboccipital craniotomy was performed. To relieve the intracranial pressure, cerebrospinal fluid (CSF) was drained via a lateral ventricular catheter in the occipital horn. During the opening of the dura, the brain swelling had progressed, and brain computed tomography revealed an intratumoral hemorrhage with brainstem compression. The patient was in a stuporous mental state. A reoperation was performed, and the mass was totally removed. The pathologic findings revealed a medulloblastoma with abnormal enlarged arterial vascular structures. Postoperatively, the patient recovered to an alert mental state. She underwent chemotherapy and radiotherapy. There was no recurrence after 1 year. Pre-resectional CSF drainage should not be routinely performed in posterior fossa tumors, especially with increased cerebral blood volume on MR perfusion images. Complete removal should be performed quickly while CSF drainage should be performed slowly. An intratumoral hemorrhage should be considered in posterior fossa tumors when severe brain swelling suddenly develops after CSF drainage. © 2016 S. Karger AG, Basel.

  3. Unique usage of a partially covered metal stent for drainage of a pancreatic pseudocyst via endosonography-guided transcystgastrostomy.

    PubMed

    Nici, Anthony J; Hussain, Syed A; Kim, Sang H; Mehta, Preeti

    2012-05-01

    Pancreatic pseudocysts are frequent complications of pancreatitis episodes. The current therapeutic modalities for drainage of pancreatic pseudocysts include surgical, percutaneous, and endoscopic drainage modalities. Endosonography-assisted endoscopic drainage of these pseudocysts with the placement of multiple plastic or fully covered self-expanding biliary metal stents is becoming more commonly carried out. The present case report discusses the unique and successful drainage of a pancreatic pseudocyst with the placement of a partially covered self-expanding metal stent. © 2012 The Authors. Digestive Endoscopy © 2012 Japan Gastroenterological Endoscopy Society.

  4. Medical management of venous ulcers.

    PubMed

    Pascarella, Luigi; Shortell, Cynthia K

    2015-03-01

    Venous disease is the most common cause of chronic leg ulceration and represents an advanced clinical manifestation of venous insufficiency. Due to their frequency and chronicity, venous ulcers have a high socioeconomic impact, with treatment costs accounting for 1% of the health care budget in Western countries. The evaluation of patients with venous ulcers should include a thorough medical history for prior deep venous thrombosis, assessment for an hypercoagulable state, and a physical examination. Use of the CEAP (clinical, etiology, anatomy, pathophysiology) Classification System and the revised Venous Clinical Severity Scoring System is strongly recommended to characterize disease severity and assess response to treatment. This venous condition requires lifestyle modification, with affected individuals performing daily intervals of leg elevation to control edema; use of elastic compression garments; and moderate physical activity, such as walking wearing below-knee elastic stockings. Meticulous skin care, treatment of dermatitis, and prompt treatment of cellulitis are important aspects of medical management. The pharmacology of chronic venous insufficiency and venous ulcers include essentially two medications: pentoxifylline and phlebotropic agents. The micronized purified flavonoid fraction is an effective adjunct to compression therapy in patients with large, chronic ulceration. Copyright © 2015 Elsevier Inc. All rights reserved.

  5. Prediction of Clinical Outcomes in Prenatal Hydronephrosis: Importance of Gravity Assisted Drainage.

    PubMed

    Sussman, Rachael D; Blum, Emily S; Sprague, Bruce M; Majd, Massoud; Rushton, H Gil; Pohl, Hans G

    2017-03-01

    In infants with SFU (Society for Fetal Urology) grade 3-4 congenital hydronephrosis, 99m Tc-mercaptoacetyltriglycine diuretic renography assesses differential function and drainage half-time. We routinely also include the percent of radiotracer drained after 30 minutes of diuresis as well as after 15 minutes with the patient in the upright position. We investigated whether any 1 or more of these parameters on initial diuretic renography predicts persistent or worsening drainage parameters. Infants 6 months or younger with grade 3-4 congenital hydronephrosis who presented between January 2009 and December 2014 were identified from billing data and included in analysis if they underwent at least 1 baseline diuretic renography. Those with structural anomalies were excluded from study. Baseline and followup differential function, diuresis half-time, clearance at 30 minutes and clearance with the patient upright were abstracted and comparisons were made between those with initially indeterminate diuresis half-time who underwent pyeloplasty vs those showing spontaneous improvement. A total of 74 patients (82 renal units) with presumed ureteropelvic junction obstruction met inclusion/exclusion criteria. All 10 renal units with initial diuresis half-time less than 5 minutes resolved spontaneously and all 25 renal units with initial diuresis half-time greater than 75 minutes underwent pyeloplasty. Therefore, we defined the indeterminate group as the 47 renal units with initial half-time between 5 and 75 minutes. Of those 47 renal units with indeterminate initial diuresis half-time 23 (47%) underwent pyeloplasty and 25 (53%) resolved spontaneously. Indications for pyeloplasty included worsening in 17 cases, persistent obstruction in 4 and urinary tract infection in 1. Among renal units with indeterminate drainage clearance while upright and clearance at 30 minutes were the only variables that differed significantly between surgical cases and those that resolved

  6. Use of computer-assisted design and manufacturing to localize dural venous sinuses during reconstructive surgery for craniosynostosis.

    PubMed

    Iyer, Rajiv R; Wu, Adela; Macmillan, Alexandra; Musavi, Leila; Cho, Regina; Lopez, Joseph; Jallo, George I; Dorafshar, Amir H; Ahn, Edward S

    2018-01-01

    Cranial vault remodeling surgery for craniosynostosis carries the potential risk of dural venous sinus injury given the extensive bony exposure. Identification of the dural venous sinuses can be challenging in patients with craniosynostosis given the lack of accurate surface-localizing landmarks. Computer-aided design and manufacturing (CAD/CAM) has allowed surgeons to pre-operatively plan these complex procedures in an effort to increase reconstructive efficiency. An added benefit of this technology is the ability to intraoperatively map the dural venous sinuses based on pre-operative imaging. We utilized CAD/CAM technology to intraoperatively map the dural venous sinuses for patients undergoing reconstructive surgery for craniosynostosis in an effort to prevent sinus injury, increase operative efficiency, and enhance patient safety. Here, we describe our experience utilizing this intraoperative technology in pediatric patients with craniosynostosis. We retrospectively reviewed the charts of children undergoing reconstructive surgery for craniosynostosis using CAD/CAM surgical planning guides at our institution between 2012 and 2016. Data collected included the following: age, gender, type of craniosynostosis, estimated blood loss, sagittal sinus deviation from the sagittal suture, peri-operative outcomes, and hospital length of stay. Thirty-two patients underwent reconstructive cranial surgery for craniosynostosis, with a median age of 11 months (range, 7-160). Types of synostosis included metopic (6), unicoronal (6), sagittal (15), lambdoid (1), and multiple suture (4). Sagittal sinus deviation from the sagittal suture was maximal in unicoronal synostosis patients (10.2 ± 0.9 mm). All patients tolerated surgery well, and there were no occurrences of sagittal sinus, transverse sinus, or torcular injury. The use of CAD/CAM technology allows for accurate intraoperative dural venous sinus localization during reconstructive surgery for craniosynostosis and

  7. Catheter interventional treatment of congenital portosystemic venous shunts in childhood.

    PubMed

    Knirsch, Walter; Benz, Dominik C; Bühr, Patrick; Quandt, Daniel; Weber, Roland; Kellenberger, Christian; Braegger, Christian P; Kretschmar, Oliver

    2016-06-01

    The study aimed on the catheter interventional treatment of congenital portosystemic venous shunt (CPSVS) in childhood and the impact on vascular growth of hypoplastic portal veins. Clinical course and follow up of partial or complete closure of CPSVS are described. CPSVS is a very rare vascular malformation of the portal venous drainage resulting in potentially life threatening abdominal, pulmonary, cerebral, and cardiac complications. The anatomic type, clinical course, and diagnosis must be determined for optimal management. Single centre case series. Eight (6 female) children with extrahepatic (n = 5) and intrahepatic (n = 3) CPSVS were diagnosed invasively by catheterization, including test balloon occlusion of the shunt and simultaneous retrograde angiography, and treated by catheter interventions (n = 5) with partial (n = 2) and complete (n = 3) occlusion of CPSVS at a median age of 3.9 years (range 0.7-21). Congenital heart disease (CHD) was the most frequent associated organ manifestation (n = 5) followed by mild to severe pulmonary arterial hypertension (n = 4), hepatopulmonary syndrome (n = 2), and portosystemic encephalopathy (n = 1). CHD was simple (n = 3) or complex type (n = 2). Three patients were untreated so far, because they were in excellent clinical condition at an age <1 year, refused treatment, or planned for later treatment. Accurate invasive diagnosis of CPSVS with test balloon occlusion of the shunt is mandatory to depict the anatomic situation. Catheter interventional treatment of CPSVS offers a feasible and safe approach with complete or partial closure of the vascular malformation inducing potentially significant vascular growth of a former hypoplastic portal venous system. © 2015 Wiley Periodicals, Inc. © 2015 Wiley Periodicals, Inc.

  8. A New Technique for Femoral Venous Access in Infants Using Arterial Injection Venous Return Guidance

    PubMed Central

    Ebishima, Hironori; Kitano, Masataka; Kurosaki, Kenichi; Shiraishi, Isao

    2017-01-01

    Objectives: Although venography guidance is helpful for central venous catheter placement, it is sometimes difficult to place a peripheral intravenous cannula for enhancement. We designed a new technique for establishing femoral venous access using venography guidance in the return phase of peripheral arteriography. This new technique was named arterial injection venous return guidance. Here we assessed the efficacy and safety of arterial injection venous return guidance. Methods: We reviewed data of 29 infants less than 6 months old undergoing catheter intervention at our institute in 2014. Of the 29 patients, femoral venous cannulation was performed using arterial injection venous return guidance in 5 patients, venography in 20 patients, and the landmark method in 4 patients. The technical success rates and incidence of complications were compared. Results: The overall success rates were 100% in the arterial injection venous return-guided and venography-guided groups. The mean procedure duration and mean contrast material injection time were similar between the groups. The contrast effect on the femoral vein in the arterial injection venous return-guided group was lower than that in the venography-guided group, but adequate for surgery. The overall complication rate was 17%, and obstruction of previously placed intravenous catheters was the most common complication. Conclusions: Therefore, the arterial injection venous return guidance technique was as safe and efficient as venography for establishing venous access. PMID:29034015

  9. Overall Quality of Fruits and Vegetables Products Affected by the Drying Processes with the Assistance of Vacuum-Microwaves.

    PubMed

    Figiel, Adam; Michalska, Anna

    2016-12-30

    The seasonality of fruits and vegetables makes it impossible to consume and use them throughout the year, thus numerous processing efforts have been made to offer an alternative to their fresh consumption and application. To prolong their availability on the market, drying has received special attention as currently this method is considered one of the most common ways for obtaining food and pharmaceutical products from natural sources. This paper demonstrates the weakness of common drying methods applied for fruits and vegetables and the possible ways to improve the quality using different drying techniques or their combination with an emphasis on the microwave energy. Particular attention has been drawn to the combined drying with the assistance of vacuum-microwaves. The quality of the dried products was ascribed by chemical properties including the content of polyphenols, antioxidant capacity and volatiles as well as physical parameters such as color, shrinkage, porosity and texture. Both these fields of quality classification were considered taking into account sensory attributes and energy aspects in the perspective of possible industrial applications. In conclusion, the most promising way for improving the quality of dried fruit and vegetable products is hybrid drying consisting of osmotic dehydration in concentrated fruit juices followed by heat pump drying and vacuum-microwave finish drying.

  10. Overall Quality of Fruits and Vegetables Products Affected by the Drying Processes with the Assistance of Vacuum-Microwaves

    PubMed Central

    Figiel, Adam; Michalska, Anna

    2016-01-01

    The seasonality of fruits and vegetables makes it impossible to consume and use them throughout the year, thus numerous processing efforts have been made to offer an alternative to their fresh consumption and application. To prolong their availability on the market, drying has received special attention as currently this method is considered one of the most common ways for obtaining food and pharmaceutical products from natural sources. This paper demonstrates the weakness of common drying methods applied for fruits and vegetables and the possible ways to improve the quality using different drying techniques or their combination with an emphasis on the microwave energy. Particular attention has been drawn to the combined drying with the assistance of vacuum-microwaves. The quality of the dried products was ascribed by chemical properties including the content of polyphenols, antioxidant capacity and volatiles as well as physical parameters such as color, shrinkage, porosity and texture. Both these fields of quality classification were considered taking into account sensory attributes and energy aspects in the perspective of possible industrial applications. In conclusion, the most promising way for improving the quality of dried fruit and vegetable products is hybrid drying consisting of osmotic dehydration in concentrated fruit juices followed by heat pump drying and vacuum-microwave finish drying. PMID:28042845

  11. Streamflow distribution maps for the Cannon River drainage basin, southeast Minnesota, and the St. Louis River drainage basin, northeast Minnesota

    USGS Publications Warehouse

    Smith, Erik A.; Sanocki, Chris A.; Lorenz, David L.; Jacobsen, Katrin E.

    2017-12-27

    Streamflow distribution maps for the Cannon River and St. Louis River drainage basins were developed by the U.S. Geological Survey, in cooperation with the Legislative-Citizen Commission on Minnesota Resources, to illustrate relative and cumulative streamflow distributions. The Cannon River was selected to provide baseline data to assess the effects of potential surficial sand mining, and the St. Louis River was selected to determine the effects of ongoing Mesabi Iron Range mining. Each drainage basin (Cannon, St. Louis) was subdivided into nested drainage basins: the Cannon River was subdivided into 152 nested drainage basins, and the St. Louis River was subdivided into 353 nested drainage basins. For each smaller drainage basin, the estimated volumes of groundwater discharge (as base flow) and surface runoff flowing into all surface-water features were displayed under the following conditions: (1) extreme low-flow conditions, comparable to an exceedance-probability quantile of 0.95; (2) low-flow conditions, comparable to an exceedance-probability quantile of 0.90; (3) a median condition, comparable to an exceedance-probability quantile of 0.50; and (4) a high-flow condition, comparable to an exceedance-probability quantile of 0.02.Streamflow distribution maps were developed using flow-duration curve exceedance-probability quantiles in conjunction with Soil-Water-Balance model outputs; both the flow-duration curve and Soil-Water-Balance models were built upon previously published U.S. Geological Survey reports. The selected streamflow distribution maps provide a proactive water management tool for State cooperators by illustrating flow rates during a range of hydraulic conditions. Furthermore, after the nested drainage basins are highlighted in terms of surface-water flows, the streamflows can be evaluated in the context of meeting specific ecological flows under different flow regimes and potentially assist with decisions regarding groundwater and surface

  12. Imprint cytology on microcalcifications excised by vacuum-assisted breast biopsy: a rapid preliminary diagnosis.

    PubMed

    Fotou, Maria; Oikonomou, Vassiliki; Zagouri, Flora; Sergentanis, Theodoros N; Nonni, Afroditi; Athanassiadou, Pauline; Drouveli, Theodora; Atsouris, Efstratios; Kotzia, Evagelia; Zografos, George C

    2007-04-03

    To evaluate imprint cytology in the context of specimens with microcalcifications derived from Vacuum-Assisted Breast Biopsy (VABB). A total of 93 women with microcalcifications BI-RADS 3 and 4 underwent VABB and imprint samples were examined. VABB was performed on Fischer's table using 11-gauge Mammotome vacuum probes. A mammogram of the cores after the procedure confirmed the excision of microcalcifications. For the application of imprint cytology, the cores with microcalcifications confirmed by mammogram were gently rolled against glass microscope slides and thus imprint smears were made. For rapid preliminary diagnosis Diff-Quick stain, modified Papanicolaou stain and May Grunwald Giemsa were used. Afterwards, the core was dipped into a CytoRich Red Collection fluid for a few seconds in order to obtain samples with the use of the specimen wash. After the completion of cytological procedures, the core was prepared for routine histological study. The pathologist was blind to the preliminary cytological results. The cytological and pathological diagnoses were comparatively evaluated. According to the pathological examination, 73 lesions were benign, 15 lesions were carcinomas (12 ductal carcinomas in situ, 3 invasive ductal carcinomas), and 5 lesions were precursor: 3 cases of atypical ductal hyperplasia (ADH) and 2 cases of lobular neoplasia (LN). The observed sensitivity and specificity of the cytological imprints for cancer were 100% (one-sided, 97.5% CI: 78.2%-100%). Only one case of ADH could be detected by imprint cytology. Neither of the two LN cases was detected by the imprints. The imprints were uninformative in 11 out of 93 cases (11.8%). There was no uninformative case among women with malignancy. Imprint cytology provides a rapid, accurate preliminary diagnosis in a few minutes. This method might contribute to the diagnosis of early breast cancer and possibly attenuates patients' anxiety.

  13. [Clinical application of continuous douche and vacuum sealing drainage in refractory tissue, bone and joint infections after debridement].

    PubMed

    Yang, Ping-lin; He, Xi-jing; Li, Hao-peng; Wang, Guo-yu; Zang, Quan-jin

    2010-01-01

    To explore effect and the application value of continuous douche and vacuum sealing drainage (VSD) in refractory tissue, and joint infections after complete debridement. As retrospective analysis of treatment time and restoration or recurrence, from Jan. 2006 to Dec. 2007, 61 cases of refractory tissue, bone and joint infections underwent continuous douche and VSD combined with the treatment of anti-inflammatory and rehabilitation training after debridement in our hospital. The 61 patients included 39 males and 22 females with age ranging from 10 to 58 years with an average of (35 +/- 12) years, among whom 61 identified to have ankle ulcers combined with infections,open fracture combined with infections, sacrococcygeal pressure ulcers combined with infections, infections after hip replacement, infections after open fracture, and infections after skin avulsion postoperation were 11, 15, 9, 3, 5 and 18 cases respectively. The course was from 2 weeks to 11 months with an average of 4 months. In all 61 patients,the mean healing time was 17, 36, 42, 24, 32, 29 and 28 days in ankle ulcers and infections, tibia and fibula open fracture and infections, femoral shaft fracture and infections, sacrococcygeal pressure ulcers and infections, infections after hip replacement, infections after open fracture, and infections after skin avulsion postoperation respectively. The replacement of VSD was 1, 2-4, 3-5, 1-3, 2-4, 2-3 and 1-3 times in each group respectively. There was no wound recurrence except for 2 cases with recurrent in 61 cases with external fixation nail hole semi-pathological fracture in 1 case of femoral shaft fracture and infection and 1 case of tibia and fibula fracture and infection after follow-up at least one year. Application of continuous douche and VSD can effectively decrease incidence of complications and promote the refractory tissue, bone and joint infections wound growth, healing and considerably shorten the healing time.

  14. Unicameral bone cyst: radiographic assessment of venous outflow by cystography as a prognostic index.

    PubMed

    Ramirez, Ana; Abril, Juan Carlos; Touza, Alberto

    2012-11-01

    The aim of this study was to determine the benefits of cystography in the management of a simple bone cyst, its implication in the final result of the treatment after corticoid intracystic injections, and the presence of secondary effects. We retrospectively reviewed 42 patients diagnosed with a simple bone cyst. Cystography was performed before the corticoid injection. The presence or absence of loculation intracyst and the existence and number of venous outflows were determined. According to the venous drainage, cysts were classified as type 0 when a venous outflow did not exist and as type 1 when there was a rapid venous outflow (<3 min). The treatment protocol included a maximum of three corticoid injections at an interval of 6 months. Healing of the cyst was determined on the basis of Neer's criteria. Secondary effects and surgical complications were assessed. Cystography studies showed a unicameral bone cyst with absent loculation in 16 cases (37.3%), whereas the lesion showed multiloculation in 26 cases (62.7%). There was no statistical difference between loculation intracyst (present or absent) and the final outcomes of the 42 cysts treated with a steroid injection (P=0.9). Cystography showed a negative venogram in 10 cases (23.8%), whereas the cysts showed a rapid venous outflow in 32 cases (76.2%). On the basis of Neer's classification, all patients with a negative venogram achieved complete healing of the cyst. Patients with a rapid venous outflow achieved complete healing in 14 cases (Neer I). In two patients, the healing was incomplete at the end of the follow-up period (Neer IV). In most cases (21 cysts), healing was partial (Neer II). Five patients showed a recurrence after initial healing of the cyst (Neer III) (P<0.05). The number or the size of veins did not affect healing of a bone cyst (P=0.6). Two patients with a rapid venous outflow showed a generalized hypertrichosis after the first injection of corticosteroids. Sex and age at the initiation

  15. Postcorrective surgery improvement of nocturnal hypoxemia in a case of partial anomalous pulmonary venous connection and aberrant hepatic vein drainage.

    PubMed

    Agrawal, Abhinav; Palkar, Atul V; Sahni, Sonu; Vatsia, Sheel K; Shah, Rakesh D; Talwar, Arunabh

    2016-01-01

    Partial anomalous pulmonary venous connection (PAPVC) is a rare congenital anomaly that leads to an anatomical left-to-right shunt. Termination of the intrahepatic inferior vena cava (IVC) with its azygos continuation associated with the hepatic venous connection to the left atrium (LA) is also a rare congenital anomaly that results in an anatomical right-to-left shunt. A 65-year-old male presented with severe dyspnea on exertion and pedal edema. He was further diagnosed at our clinic and was found to have both the aforementioned congenital abnormalities, creating a bidirectional shunt. On further investigation, he was found to have nocturnal hypoxemia on overnight oximetry. The patient was successfully treated via surgical corrections of the congenital anomalies leading to symptomatic improvement as well as the resolution of nocturnal hypoxemia.

  16. An ultrahigh vacuum, low-energy ion-assisted deposition system for III-V semiconductor film growth

    NASA Astrophysics Data System (ADS)

    Rohde, S.; Barnett, S. A.; Choi, C.-H.

    1989-06-01

    A novel ion-assisted deposition system is described in which the substrate and growing film can be bombarded with high current densities (greater than 1 mA/sq cm) of very low energy (10-200 eV) ions. The system design philosophy is similar to that used in III-V semiconductor molecular-beam epitaxy systems: the chamber is an all-metal ultrahigh vacuum system with liquid-nitrogen-cooled shrouds, Knudsen-cell evaporation sources, a sample insertion load-lock, and a 30-kV reflection high-energy electron diffraction system. III-V semiconductor film growth is achieved using evaporated group-V fluxes and group-III elemental fluxes sputtered from high-purity targets using ions extracted from a triode glow discharge. Using an In target and an As effusion cell, InAs deposition rates R of 2 microns/h have been obtained. Epitaxial growth of InAs was observed on both GaSb(100) and Si(100) substrates.

  17. Aerosol Vacuum-Assisted Plasma Ionization (Aero-VaPI) Coupled to Ion Mobility-Mass Spectrometry

    NASA Astrophysics Data System (ADS)

    Blair, Sandra L.; Ng, Nga L.; Zambrzycki, Stephen C.; Li, Anyin; Fernández, Facundo M.

    2018-02-01

    In this communication, we report on the real-time analysis of organic aerosol particles by Vacuum-assisted Plasma Ionization-Mass Spectrometry (Aero-VaPI-MS) using a home-built VaPI ion source coupled to a Synapt G2-S HDMS ion mobility-mass spectrometry (IM-MS) system. Standards of organic molecules of interest in prebiotic chemistry were used to generate aerosols. Monocaprin and decanoic acid aerosol particles were successfully detected in both the positive and negative ion modes, respectively. A complex aerosol mixture of different sizes of polymers of L-malic acid was also examined through ion mobility (IM) separations, resulting in the detection of polymers of up to eight monomeric units. This noncommercial plasma ion source is proposed as a low cost alternative to other plasma ionization platforms used for aerosol analysis, and a higher-performance alternative to more traditional aerosol mass spectrometers. VaPI provides robust online ionization of organics in aerosols without extensive ion activation, with the coupling to IM-MS providing higher peak capacity and excellent mass accuracy. [Figure not available: see fulltext.

  18. Comparison between autologous blood transfusion drainage and closed-suction drainage/no drainage in total knee arthroplasty: a meta-analysis.

    PubMed

    Hong, Kun-Hao; Pan, Jian-Ke; Yang, Wei-Yi; Luo, Ming-Hui; Xu, Shu-Chai; Liu, Jun

    2016-08-01

    Autologous blood transfusion (ABT) drainage system is a new unwashed salvaged blood retransfusion system for total knee replacement (TKA). However, whether to use ABT drainage, closed-suction (CS) drainage or no drainage in TKA surgery remains controversial. This is the first meta-analysis to assess the clinical efficiency, safety and potential advantages regarding the use of ABT drains compared with closed-suction/no drainage. PubMed, Embase, and the Cochrane Library were comprehensively searched in March 2015. Fifteen randomized controlled trials (RCTs) were identified and pooled for statistical analysis. The primary outcome evaluated was homologous blood transfusion rate. The secondary outcomes were post-operative haemoglobin on days 3-5, length of hospital stay and wound infections after TKA surgery. The pooled data included 1,721 patients and showed that patients in the ABT drainage group might benefit from lower blood transfusion rates (16.59 % and 37.47 %, OR: 0.28 [0.14, 0.55]; 13.05 % and 16.91 %, OR: 0.73 [0.47,1.13], respectively). Autologous blood transfusion drainage and closed-suction drainage/no drainage have similar clinical efficacy and safety with regard to post-operative haemoglobin on days 3-5, length of hospital stay and wound infections. Autologous blood transfusion drainage offers a safe and efficient alternative to CS/no drainage with a lower blood transfusion rate. Future large-volume high-quality RCTs with extensive follow-up will affirm and update this system review.

  19. Novel application of vacuum sealing drainage with continuous irrigation of potassium permanganate for managing infective wounds of gas gangrene.

    PubMed

    Hu, Ning; Wu, Xing-Huo; Liu, Rong; Yang, Shu-Hua; Huang, Wei; Jiang, Dian-Ming; Wu, Qiang; Xia, Tian; Shao, Zeng-Wu; Ye, Zhe-Wei

    2015-08-01

    Traumatic gas gangrene is a fatal infection mainly caused by Clostridium perfringens. It is a challenge to manage gas gangrene in open wounds and control infection after debridement or amputation. The aim of the present study was to use vacuum sealing drainage (VSD) with continuous irrigation of potassium permanganate to manage infective wounds of gas gangrene and observe its clinical efficacy. A total of 48 patients with open traumatic gas gangrene infection were included in this study. Amputations were done for 27 patients, and limb salvage procedures were performed for the others. After amputation or aggressive debridement, the VSD system, including polyvinyl alcohol (PVA) foam dressing and polyurethane (PU) film, with continuous irrigation of 1:5000 potassium permanganate solutions, was applied to the wounds. During the follow-up, all the patients healed without recurrence within 8-18 months. There were four complications. Cardiac arrest during amputation surgery occurred in one patient who suffered from severe septic shock. Emergent resuscitation was performed and the patient returned to stable condition. One patient suffered from mixed infection of Staphylococcal aureus, and a second-stage debridement was performed. One patient suffered from severe pain of the limb after the debridement. Exploratory operation was done and the possible reason was trauma of a local peripheral nerve. Three cases of crush syndrome had dialysis treatment for concomitant renal failure. In conclusion, VSD can convert open wound to closed wound, and evacuate necrotic tissues. Furthermore, potassium permanganate solutions help eliminate anaerobic microenvironment and achieve good therapeutic effect on gas gangrene and mixed infection. VSD with continuous irrigation of potassium permanganate is a novel, simple and feasible alternative for severe traumatic open wounds with gas gangrene infection.

  20. Use of the retrograde limb of the internal mammary vein to avoid venous congestion in DIEP flap breast reconstruction: Further evidences of a reliable and time-sparing procedure.

    PubMed

    La Padula, Simone; Hersant, Barbara; Noel, Warren; Niddam, Jeremy; Hermeziu, Oana; Bouhassira, Jonathan; Bosc, Romain; Meningaud, Jean Paul

    2016-09-01

    Venous congestion is a common cause of DIEP flap failure. When identified intraoperatively, an additional venous anastomosis can improve the venous outflow and prevent flap failure. The aim of this study was to assess if the retrograde limb of the internal mammary vein (IMV) could be considered a good recipient vessel to be used when persistent flap congestion is present, and a second venous anastomosis is required. A retrospective study was conducted in 74 patients who had undergone DIEP flap breast reconstruction. Patients were classified into two groups: SVA (single venous anastomosis) and DVA (dual venous anastomosis). In the SVA group (n = 38), the IMV antegrade limb was used for venous drainage. A single DIEV (Deep Inferior Epigastric Vein) was anastomosed to the superior arm of the IMV. In the DVA group (n = 36), both the antegrade (superior) and retrograde (inferior) stumps of the IMV were used, connecting the larger DIEV to the antegrade IMV and the other DIEV or the SIEV (Superficial Inferior Epigastric Vein) to the IMV retrograde limb. No venous congestion or flap loss was observed when two venous anastomoses were performed using both the IMV antegrade and retrograde limbs (P = 0.3271). In the DVA group, no major complication occurred (P = 0.0453). Operative explorations were significantly reduced in the DVA group (P = 0.0242). These findings suggest that when an additional venous outflow is required, the use of the IMV retrograde limb may help to avoid flap venous congestion. © 2016 Wiley Periodicals, Inc. Microsurgery 36:447-452, 2016. © 2016 Wiley Periodicals, Inc.

  1. Quantifying the Cerebral Hemodynamics of Dural Arteriovenous Fistula in Transverse Sigmoid Sinus Complicated by Sinus Stenosis: A Retrospective Cohort Study.

    PubMed

    Guo, W-Y; Lee, C-C J; Lin, C-J; Yang, H-C; Wu, H-M; Wu, C-C; Chung, W-Y; Liu, K-D

    2017-01-01

    Sinus stenosis occasionally occurs in dural arteriovenous fistulas. Sinus stenosis impedes venous outflow and aggravates intracranial hypertension by reversing cortical venous drainage. This study aimed to analyze the likelihood of sinus stenosis and its impact on cerebral hemodynamics of various types of dural arteriovenous fistulas. Forty-three cases of dural arteriovenous fistula in the transverse-sigmoid sinus were reviewed and divided into 3 groups: Cognard type I, type IIa, and types with cortical venous drainage. Sinus stenosis and the double peak sign (occurrence of 2 peaks in the time-density curve of the ipsilateral drainage of the internal jugular vein) in dural arteriovenous fistula were evaluated. "TTP" was defined as the time at which a selected angiographic point reached maximum concentration. TTP of the vein of Labbé, TTP of the ipsilateral normal transverse sinus, trans-fistula time, and trans-stenotic time were compared across the 3 groups. Thirty-six percent of type I, 100% of type IIa, and 84% of types with cortical venous drainage had sinus stenosis. All sinus stenosis cases demonstrated loss of the double peak sign that occurs in dural arteriovenous fistula. Trans-fistula time (2.09 seconds) and trans-stenotic time (0.67 seconds) in types with cortical venous drainage were the most prolonged, followed by those in type IIa and type I. TTP of the vein of Labbé was significantly shorter in types with cortical venous drainage. Six patients with types with cortical venous drainage underwent venoplasty and stent placement, and 4 were downgraded to type IIa. Sinus stenosis indicated dysfunction of venous drainage and is more often encountered in dural arteriovenous fistula with more aggressive types. Venoplasty ameliorates cortical venous drainage in dural arteriovenous fistulas and serves as a bridge treatment to stereotactic radiosurgery in most cases. © 2017 by American Journal of Neuroradiology.

  2. Current topics in surgery for isolated total anomalous pulmonary venous connection.

    PubMed

    Yoshimura, Naoki; Fukahara, Kazuaki; Yamashita, Akio; Doki, Yoshinori; Takeuchi, Katsunori; Higuma, Tomonori; Senda, Kazutaka; Toge, Masayoshi; Matsuo, Tatsuro; Nagura, Saori; Aoki, Masaya; Sakata, Kimimasa; Obi, Hayato

    2014-12-01

    Surgical correction of total anomalous pulmonary venous connection (TAPVC) remains a challenge, with reported early mortality rates of up to 20%. In this review article, we describe several topics, including surgery for neonates, diagnoses with multidetector computed tomography (MDCT), and primary sutureless repair. Several studies have reported mortality rates of around 10%, and demonstrated unchanged hospital mortality in neonates, despite improvement of the overall mortality of cohorts including older patients. Previous reports identified a low body weight at the time of the operation, preoperative pulmonary venous obstruction (PVO), and a prolonged cardiopulmonary bypass time as risk factors for hospital mortality. With the development of new technologies, MDCT has become a good diagnostic modality for use in the pre- and post-operative evaluation. MDCT delineates the drainage site of the vertical vein and the atypical vessel into the systemic vein, and it can also evaluate the existence of obstruction in the vertical vein. Following favorable experiences with post-repair PVO, the indications for sutureless repair as a primary operation have been expanded for infants, including those at risk of developing PVO after the repair of TAPVC. Primary sutureless repair has proven especially useful for difficult patient groups, such as those with congenital PVO, infracardiac TAPVC with small pulmonary veins, or mixed-type TAPVC.

  3. Risk factors for venous thrombosis associated with peripherally inserted central venous catheters

    PubMed Central

    Pan, Longfang; Zhao, Qianru; Yang, Xiangmei

    2014-01-01

    To evaluate the risk factors associated with an increased risk of symptomatic peripherally inserted central venous catheter (PICC)-related venous thrombosis. Retrospective analyses identified 2313 patients who received PICCs from 1 January 2012 to 31 December 2013. All 11 patients with symptomatic PICC-related venous thrombosis (thrombosis group) and 148 who did not have thromboses (non-thrombosis group) were selected randomly. The medical information of 159 patients (age, body mass index (BMI), diagnosis, smoking history, nutritional risk score, platelet count, leucocyte count as well as levels of D-dimer, fibrinogen, and degradation products of fibrin) were collected. Logistic regression analysis was undertaken to determine the risk factors for thrombosis. Of 2313 patients, 11 (0.47%) were found to have symptomatic PICC-related venous thrombosis by color Doppler ultrasound. Being bedridden for a long time (odds ratio [(OR]), 17.774; P=0.0017), D-dimer >5 mg/L (36.651; 0.0025) and suffering from one comorbidity (8.39; 0.0265) or more comorbidities (13.705; 0.0083) were the major risk factors for PICC-catheter related venous thrombosis by stepwise logistic regression analysis. Among 159 patients, the prevalence of PICC-associated venous thrombosis in those with ≥1 risk factor was 10.34% (12/116), in those with ≥2 risk factors was 20.41% (10/49), and in those with >3 risk factors was 26.67% (4/15). Being bedridden >72 h, having increased levels of D-dimer (>5 mg/L) and suffering from comorbidities were independent risk factors of PICC-related venous thrombosis. PMID:25664112

  4. Resin Flow Behavior Simulation of Grooved Foam Sandwich Composites with the Vacuum Assisted Resin Infusion (VARI) Molding Process

    PubMed Central

    Zhao, Chenhui; Zhang, Guangcheng; Wu, Yibo

    2012-01-01

    The resin flow behavior in the vacuum assisted resin infusion molding process (VARI) of foam sandwich composites was studied by both visualization flow experiments and computer simulation. Both experimental and simulation results show that: the distribution medium (DM) leads to a shorter molding filling time in grooved foam sandwich composites via the VARI process, and the mold filling time is linearly reduced with the increase of the ratio of DM/Preform. Patterns of the resin sources have a significant influence on the resin filling time. The filling time of center source is shorter than that of edge pattern. Point pattern results in longer filling time than of linear source. Short edge/center patterns need a longer time to fill the mould compared with Long edge/center sources.

  5. Values of pathological analysis of lost tissue fragments in the vacuum canister during a vacuum-assisted stereotactic biopsy of the breast.

    PubMed

    El Khoury, M; Mesurolle, B; Omeroglu, A; Aldis, A; Kao, E

    2013-05-01

    Determine values of pathological analysis of the canister content during a vacuum-assisted breast biopsy (VABB). Approval was obtained from the ethical committee. Prospective radiological and pathological analyses of the canister content collected during 231 VABBs performed on 231 patients were carried out. χ(2) test was used to determine predictors on canister pathology. The canister pathology was reported separately in 212 cases. It showed only blood in 78/212 (37%) cases and benign (including high-risk lesions) and malignant results in, respectively, 113/212 (53%) and 21/212 (10%) cases. Respective specimen analysis was benign, including high-risk lesions in 162/212 cases (76%) and malignant in 50/212 (24%) cases. Microcalcifications were documented on canister X-ray in 70/231 (30%) cases. There was significant association between the canister and the specimen pathology (p<0.0001). In none of the cases was microcalcifications seen exclusively in the canister content or pathological upgrading found in the canister content compared with the specimen. Small tissue fragments and microcalcifications may be lost in the canister during a VABB. Nevertheless, our results did not show any significant value for systematic analysis of the canister content. There is no added diagnostic value to retrieval and analysis of tissue lost in the canister during a VABB.

  6. Symptoms in patients with skin changes due to chronic venous insufficiency often lead to emergency care service: an Italian observational study.

    PubMed

    Ruggiero, Michele; Grande, Raffaele; Naso, Agostino; Butrico, Lucia; Rubino, Paolo; Placida, Girolamo Domenico; Cannistrà, Marco; Serra, Raffaele

    2016-10-01

    Chronic venous insufficiency (CVI) is the most advanced form of chronic venous disease (CVD), and is often associated with skin changes such as hyperpigmentation, eczema, lipodermatosclerosis and venous skin ulceration that cause discomfort, pain, sleep disturbances, absenteeism in the workplace, disability and deteriorated quality of life (QoL). The purpose of this study is to evaluate the prevalence of CVI and skin changes in patients who turn to Continuous Assistance Services due to the presence of disturbing symptoms of their condition. Data were evaluated by consulting the medical records, during a 16-month period, available with three Continuous Assistance Services of the Italian territory. The overall population of the referring centres consisted of 1186 patients [739 females (62·31%) and 447 males (37·69%)]. Seventy-nine patients (6·66%) consulted the emergency unit for venous symptoms related to CVD. Patients with more severe disease (CVI, categories C4-C6) represented the majority accounting for 60·75%, while patients with moderate disease (C3) accounted for 35·44% and patients with mild disease (C1-C2 stages) accounted for 3·79%. The main finding of this study is that despite CVI not being a disease that commonly requires medical emergency/urgency intervention, patients with CVI, especially in advanced stage with skin changes, may turn to Continuous Assistance Service for treating bothersome symptoms related to their condition. © 2015 Medicalhelplines.com Inc and John Wiley & Sons Ltd.

  7. Chest Tube Drainage of the Pleural Space: A Concise Review for Pulmonologists

    PubMed Central

    2018-01-01

    Chest tube insertion is a common procedure usually done for the purpose of draining accumulated air or fluid in the pleural cavity. Small-bore chest tubes (≤14F) are generally recommended as the first-line therapy for spontaneous pneumothorax in non-ventilated patients and pleural effusions in general, with the possible exception of hemothoraces and malignant effusions (for which an immediate pleurodesis is planned). Large-bore chest drains may be useful for very large air leaks, as well as post-ineffective trial with small-bore drains. Chest tube insertion should be guided by imaging, either bedside ultrasonography or, less commonly, computed tomography. The so-called trocar technique must be avoided. Instead, blunt dissection (for tubes >24F) or the Seldinger technique should be used. All chest tubes are connected to a drainage system device: flutter valve, underwater seal, electronic systems or, for indwelling pleural catheters (IPC), vacuum bottles. The classic, three-bottle drainage system requires either (external) wall suction or gravity (“water seal”) drainage (the former not being routinely recommended unless the latter is not effective). The optimal timing for tube removal is still a matter of controversy; however, the use of digital drainage systems facilitates informed and prudent decision-making in that area. A drain-clamping test before tube withdrawal is generally not advocated. Pain, drain blockage and accidental dislodgment are common complications of small-bore drains; the most dreaded complications include organ injury, hemothorax, infections, and re-expansion pulmonary edema. IPC represent a first-line palliative therapy of malignant pleural effusions in many centers. The optimal frequency of drainage, for IPC, has not been formally agreed upon or otherwise officially established. PMID:29372629

  8. Peritoneal Drainage Versus Pleural Drainage After Pediatric Cardiac Surgery.

    PubMed

    Gowda, Keshava Murty Narayana; Zidan, Marwan; Walters, Henry L; Delius, Ralph E; Mastropietro, Christopher W

    2014-07-01

    We aimed to determine whether infants undergoing cardiac surgery would more efficiently attain negative fluid balance postoperatively with passive peritoneal drainage as compared to traditional pleural drainage. A prospective, randomized study including children undergoing repair of tetralogy of Fallot (TOF) or atrioventricular septal defect (AVSD) was completed between September 2011 and June 2013. Patients were randomized to intraoperative placement of peritoneal catheter or right pleural tube in addition to the requisite mediastinal tube. The primary outcome measure was fluid balance at 48 hours postoperatively. Variables were compared using t tests or Fisher exact tests as appropriate. A total of 24 patients were enrolled (14 TOF and 10 AVSD), with 12 patients in each study group. Mean fluid balance at 48 hours was not significantly different between study groups, -41 ± 53 mL/kg in patients with periteonal drainage and -9 ± 40 mL/kg in patients with pleural drainage (P = .10). At 72 hours however, postoperative fluid balance was significantly more negative with peritoneal drainage, -52.4 ± 71.6 versus +2.0 ± 50.6 (P = .04). On subset analysis, fluid balance at 48 hours in patients with AVSD was more negative with peritoneal drainage as compared to pleural, -82 ± 51 versus -1 ± 38 mL/kg, respectively (P = .02). Fluid balance at 48 hours in patients with TOF was not significantly different between study groups. Passive peritoneal drainage may more effectively facilitate negative fluid balance when compared to pleural drainage after pediatric cardiac surgery, although this benefit is not likely universal but rather dependent on the patient's underlying physiology. © The Author(s) 2014.

  9. Transbronchial drainage using endobronchial ultrasonography with guide sheath for lung abscess: A case report.

    PubMed

    Yaguchi, Daizo; Ichikawa, Motoshi; Inoue, Noriko; Kobayashi, Daisuke; Shizu, Masato; Imai, Naoyuki

    2018-05-01

    Lung abscess was previously treated surgically, but is now mainly treated with antibiotics and ideally with direct drainage, although postural drainage canalso be used. A chest abnormal shadow was detected in an 82-year-old man and he was referred to our department in November 2017. On chest computed tomography (CT), a low-density mass shadow was present in the left S8 segment. Lung abscess and lung cancer were considered as differential diagnoses, and treatment with sulbactam sodium/ampicillin sodium (SBT/ABPC) was first initiated for lung abscess. The etiologic agent could not be identified by sputum examination, and the abscess shadow remained. Lung abscess. Endobronchial ultrasonography with a guide sheath (EBUS-GS)-guided bronchoscopy was performed on hospital day 21 to diagnose the lesion, identify the etiologic agent if the lesion was a lung abscess, and attempt drainage. Vacuum aspiration performed in the guide sheath after the probe was placed within the lesion produced 4-5 ml of gray turbid pus, and the abscess was judged to have been drained. A subsequent pathological examination did not detect malignant cells. Klebsiella pneumoniae, Prevotella spp. was identified as the etiologic agent in bacteriological tests. Antibiotics were changed based on sensitivity test results, and drainage was similarly performed on hospital day 28. The shadow gradually improved and disappeared. Therefore, this procedure and treatment led to identification of the etiologic agent and helped with cure of the disease. Based on the basic principle of treatment for abscess using as much drainage as possible, EBUS-GS-guided transbronchial drainage may be considered to be a "new procedure" for lung abscess.

  10. Forced expiratory technique, directed cough, and autogenic drainage.

    PubMed

    Fink, James B

    2007-09-01

    In health, secretions produced in the respiratory tract are cleared by mucociliary transport, cephalad airflow bias, and cough. In disease, increased secretion viscosity and volume, dyskinesia of the cilia, and ineffective cough combine to reduce secretion clearance, leading to increased risk of infection. In obstructive lung disease these conditions are further complicated by early collapse of airways, due to airway compression, which traps both gas and secretions. Techniques have been developed to optimize expiratory flow and promote airway clearance. Directed cough, forced expiratory technique, active cycle of breathing, and autogenic drainage are all more effective than placebo and comparable in therapeutic effects to postural drainage; they require no special equipment or care-provider assistance for routine use. Researchers have suggested that standard chest physical therapy with active cycle of breathing and forced expiratory technique is more effective than chest physical therapy alone. Evidence-based reviews have suggested that, though successful adoption of techniques such as autogenic drainage may require greater control and training, patients with long-term secretion management problems should be taught as many of these techniques as they can master for adoption in their therapeutic routines.

  11. Evaluation of rapid readout biological indicators for 132 degrees C gravity and 132 degrees C vacuum-assisted steam sterilization cycles using a new automated fluorescent reader.

    PubMed

    Alfa, Michelle J; Olson, Nancy; DeGagne, Pat; Jackson, Michele

    2002-07-01

    The primary objective of this study was to evaluate fluorescent readout results of Attest 1291 Biological Indicators (BIs) (3M Health Care, St. Paul, MN) and Attest 1296 BI test packs (containing Attest 1292 BIs) using full and fractional cycles compared with the growth data when prolonged incubation (7 days) was included. Gravity displacement and vacuum-assisted steam sterilization cycles were evaluated. A secondary objective of this study was to evaluate the new automated rapid fluorescent reader (Attest 290 Auto Reader). The rapid readout BIs for gravity displacement and vacuum-assisted steam autoclave cycles at 132 degrees C were processed using full (4 minutes) and four fractional cycles that provided 30% to 80% positive results for growth after 24 hours of incubation (48 hours of incubation for Attest 1292 BIs from the Attest 1296 test packs). Sixty of each type of BI were tested for each cycle (300 of each BI type in total). For all full steam sterilization cycles, results of the rapid fluorescent readout and the 24-hour, 48-hour, and 7-day growth tests were negative for all Attest 1291 and 1292 BIs tested. For all fractional cycles, the 24- and 48-hour growth results for the Attest 1291 and 1292 BIs, respectively, were the same as the 7-day growth results. The fractional cycle data indicated that fluorescent rapid readout was a more sensitive indicator than growth. There were rare (0.9%) false-negative results for BIs under fractional cycle conditions and these all correlated with short fractional cycle exposure times. The fluorescent rapid readout results of the 1291 BIs and 1296 BI test packs reliably predict both 24- and 48-hour and 7-day growth. These data support the value of rapid readout BIs for sterilizer monitoring for both the vacuum-assisted and the gravity displacement steam sterilization cycles. The new automated reader requires less manipulation of the BI and makes monitoring user friendly and less prone to user errors.

  12. Surgical model pig ex vivo for venous dissection teaching in medical schools.

    PubMed

    Tube, Milton Ignacio Carvalho; Spencer-Netto, Fernando Antonio Campelo; Oliveira, Anderson Igor Pereira de; Holanda, Arthur Cesário de; Barros, Bruno Leão Dos Santos; Rezende, Caio Cezar Gomes; Cavalcanti, João Pedro Guerra; Batista, Marília Apolinário; Campos, Josemberg Marins

    2017-02-01

    To investigate a method for development of surgical skills in medical students simulating venous dissection in surgical ex vivo pig model. Prospective, analytical, experimental, controlled study with four stages: selection, theoretical teaching, training and assessment. Sample of 312 students was divided into two groups: Group A - 2nd semester students; Group B - students of 8th semester. The groups were divided into five groups of 12 students, trained two hours per week in the semester. They set up four models to three students in each skill station assisted by a monitor. Teaching protocol emergency procedures training were applied to venous dissection, test goal-discursive and OSATS scale. The pre-test confirmed that the methodology has not been previously applied to the students. The averages obtained in the theoretical evaluation reached satisfactory parameters in both groups. The results of applying OSATS scale showed the best performance in group A compared to group B, however, both groups had satisfactory medium. The method was enough to raise a satisfactory level of skill both groups in venous dissection running on surgical swine ex vivo models.

  13. [Magnetic resonance imaging and pathological evaluation of vacuum sealing drainage efficacy of early treated limb gunshot].

    PubMed

    Li, Ronggang; Liu, Xingyan; Chen, Keming; Ye, Jianjun; Gao, Mingxuan; Ge, Baofeng; Wang, Yong; Xiong, Faming; Liang, Jianping

    2010-03-01

    Gunshot wound spreads to the surrounding tissues and organs, it is difficult to debride and easy to infect. The conventional treatment is thorough, extensive debridement, fully open drainage, which often causes normal tissue damage and complications. To evaluate the effectiveness of vacuum sealing drainage (VSD) treating the penetrating wound in porcine extremity by MRI and pathological methods so as to provide theoretical basis for future clinical use. Eight healthy adult pigs, weighing (45 +/- 5) kg, were selected. Eight pairs of hind limb penetrating wounds (16 wounds) were made by using Chinese-made 95-type rifle at 25 meters distance, which were randomly divided into experimental group (left side, n=8) and the control group (right side, n=8). After debriding and disinfecting the penetrating wounds at 6 hours after injury, wounds were treated with VSD in experimental group. The ballistics exports of the wounds were covered with single-layer gauze and imports were directly sutured and covered with sterile gauze in control group. The trajectory and the general condition of the adjacent skin were observed. MRI and histological observation were taken at 5, 24, 48, and 72 hours after injury, bacterial counting analysis was done at 0, 12, 24, 48, and 72 hours after injury. The aperture of the trajectory exit and entry were (5.00 +/- 2.50) cm and (0.30 +/- 0.15) cm immediately after injury. The wound surface was clean, rosy without leakage and swelling after 72 hours in experimental group; wound and adjacent tissue were swelling obviously, pus, muscle necrosis and exfoliative tissue was observed, and deep defect cavity at the trajectory exit could be seen in control group. MRI showed that pairs of linear low signal in T1WI and T2WI was seen in trajectory of experimental group at 5 hours after injury, and signal in T1WI gradually increased at disrupted area and tissue deformation area at 24, 48, and 72 hours; in control group, low signal in T1WI was observed at 5 hours

  14. Prospective evaluation of chronic venous insufficiency based on foot venous pressure measurements and air plethysmography findings.

    PubMed

    Fukuoka, Masato; Sugimoto, Takaki; Okita, Yutaka

    2003-10-01

    The purpose of this study was to evaluate lower extremity venous function in patients with chronic venous insufficiency, with foot venous pressure (FVP) measurements and air plethysmography (APG). Eighty-five limbs of 63 patients with a history of chronic venous insufficiency (CVI) from 1995 to 1999 were studied. FVP parameters studied included ambulatory venous pressure (AVP), percent decrease in FVP with manual calf compression (%drop), ratio of increase in FVP over 4 seconds after release of compression (4SR%), and time to 90% recovery of FVP were measured. APG parameters studied included functional venous volume, 90% refilling time (VFT90), venous filling index, ejection fraction, and residual volume fraction. Venous filling index and 90% refilling time were significantly decreased in limbs with stasis syndrome compared with the control group. AVP, %drop, and 4SR% also showed significantly decrease in limbs with stasis syndrome compared with those without it. AVP, %drop, and 4SR% were significantly different for the primary group compared with the secondary group, whereas no differences were found with regard to any APG parameter. APG enables prediction of the presence of CVI, whereas FVP measurements are more useful for evaluation of clinical severity of CVI.

  15. Processing and Properties of Vacuum Assisted Resin Transfer Molded Phenylethynyl Terminated Imide Composites

    NASA Technical Reports Server (NTRS)

    Cano, Roberto J.; Ghose, Sayata; Watson, Kent A.; Chunchu, Prasad B.; Jensen, Brian J.; Connell, John W.

    2012-01-01

    Polyimide composites are very attractive for applications that require a high strength to weight ratio and thermal stability. Recent work at NASA Langley Research Center (LaRC) has concentrated on developing new polyimide resin systems that can be processed without the use of an autoclave for advanced aerospace applications. Due to their low melt viscosities and long melt stability, certain phenylethynyl terminated imides (PETI) can be processed into composites using high temperature vacuum assisted resin transfer molding (HT-VARTM). VARTM has shown the potential to reduce the manufacturing cost of composite structures. In the current study, two PETI resins, LARC(Trademark) PETI-330 and LARC(Trademark) PETI-9, were infused into carbon fiber preforms at 260 C and cured at temperatures up to 371 C. Photomicrographs of polished cross sections were taken and void contents, determined by acid digestion, were below 4.5%. Mechanical properties including short block compression (SBC), compression after impact (CAI), and open hole compression (OHC) were determined at room temperature, 177 C, and 288 C. Both PETI-9 and PETI-330 composites demonstrated very good retention of mechanical properties at elevated temperatures. SBC and OHC properties after aging for 1000 hours at temperatures up to 288 C were also determined.

  16. Estimation of Tile Drainage Contribution to Streamflow and Nutrient Export Loads

    NASA Astrophysics Data System (ADS)

    Schilling, K. E.; Arenas Amado, A.; Jones, C. S.; Weber, L. J.

    2015-12-01

    Subsurface drainage is a very common practice in the agricultural U.S. Midwest. It is typically installed in poorly drained soils in order to enhance crop yields. The presence of tile drains creates a route for agrichemicals to travel and therefore negatively impacts stream water quality. This study estimated through end-member analyses the contributions of tile drainage, groundwater, and surface runoff to streamflow at the watershed scale based on continuously monitored data. Especial attention was devoted to quantifying tile drainage impact on watershed streamflow and nutrient export loads. Data analyzed includes streamflow, rainfall, soil moisture, shallow groundwater levels, in-stream nitrate+nitrite concentrations and specific conductance. Data were collected at a HUC12 watershed located in Northeast Iowa, USA. Approximately 60% of the total watershed area is devoted to agricultural activities and forest and grassland are the other two predominant land uses. Results show that approximately 20% of total annual streamflow comes from tile drainage and during rainfall events tile drainage contribution can go up to 30%. Furthermore, for most of the analyzed rainfall events groundwater responded faster and in a more dramatic fashion than tile drainage. The State of Iowa is currently carrying out a plan to reduce nutrients in Iowa waters and the Gulf of Mexico (Iowa Nutrient Reduction Strategy). The outcome of this investigation has the potential to assist in Best Management Practice (BMP) scenario selection and therefore help the state achieve water quality goals.

  17. Cup detachment during vacuum-assisted vaginal delivery and birth outcome.

    PubMed

    Krispin, Eyal; Aviram, Amir; Salman, Lina; Chen, Rony; Wiznitzer, Arnon; Gabbay-Benziv, Rinat

    2017-11-01

    To determine the perinatal outcome associated with cup detachment during vacuum-assisted vaginal delivery (VAVD). A retrospective cohort study of all women attempting VAVD in a tertiary hospital (2012-2014). Singleton-term pregnancies were included. Antepartum fetal death and major fetal structural or chromosomal abnormalities were excluded. Primary outcome was neonatal birth trauma (subgaleal hematoma, subarachnoid hematoma, subdural hematoma, skull fracture, and/or erb's palsy). Secondary outcomes were maternal complications or other neonatal morbidities. Outcomes were compared between women after ≥1 cup detachment (study group) and the rest (control group). Logistic regression analysis was utilized to adjust results to potential confounders. Overall, 1779 women attempted VAVD during study period. Of them, in 146 (8.2%), the cup detached prior to delivery; 130/146 (89%) had a single detachment. After detachment, 4 (2.7%) delivered by cesarean section, 77 (52.7%) delivered after cup reapplication, and 65 (44.6%) delivered spontaneously. Women in the study group were more likely to undergo VAVD due to prolonged second stage, and were characterized by lower rates of metal cup use. Neonates in the detachment group had higher rates of subarachnoid hematoma and composite neonatal birth trauma (2.7 vs. 0.1% and 4.8 vs. 1.8%, respectively, p < 0.05). This remained significant after adjustment to potential confounders (subarachnoid hematoma aOR = 45.44, 95% CI 6.42-321.62 and neonatal birth trauma aOR = 2.62, 95% CI 1.1-6.22, p < 0.05 for all). Other neonatal and maternal morbidities were similar between groups. Cup detachment is associated with a higher rate of adverse neonatal outcome. Cup reapplication should be considered carefully.

  18. Transcatheter correction of Scimitar syndrome: occlusion of abnormal pulmonary venous drainage and vascular supply in an infant.

    PubMed

    Saltik, Levent; Ugan Atik, Sezen; Bornaun, Helen

    2017-10-01

    Treatment of Scimitar syndrome is usually surgical; however, if there is "dual drainage" - that is, one to the inferior caval vein and the other to the left atrium - it is possible to successfully treat this anomaly via a less-invasive transcatheter approach. We report a case of Scimitar syndrome in a 21-month-old, male infant successfully treated with transcatheter embolisation.

  19. Warfarin-induced Venous Limb Gangrene

    PubMed Central

    Grim Hostetler, Sarah; Sopkovich, Jennifer; Dean, Steven

    2012-01-01

    Warfarin is a commonly used anticoagulant that has been associated with several significant cutaneous side effects, most notably warfarin-induced skin necrosis. A lesser known adverse reaction to warfarin is warfarin-induced venous limb gangrene. Both cutaneous adverse effects share the same pathophysiology, but are clinically quite different. The majority of cases of warfarin-induced venous limb gangrene has been in patients with cancer or heparin-induced thrombocytopenia. However, other hypercoagulable disease states, such as the antiphospholipid antibody syndrome, can be associated with venous limb gangrene. In order to increase recognition of this important condition, the authors report a case of warfarin-induced venous limb gangrene in a patient with presumed antiphospholipid antibody syndrome and review the literature on warfarin-induced venous limb gangrene. PMID:23198012

  20. Vacuum force

    NASA Astrophysics Data System (ADS)

    Han, Yongquan

    2015-03-01

    To study on vacuum force, we must clear what is vacuum, vacuum is a space do not have any air and also ray. There is not exist an absolute the vacuum of space. The vacuum of space is relative, so that the vacuum force is relative. There is a certain that vacuum vacuum space exists. In fact, the vacuum space is relative, if the two spaces compared to the existence of relative vacuum, there must exist a vacuum force, and the direction of the vacuum force point to the vacuum region. Any object rotates and radiates. Rotate bend radiate- centripetal, gravity produced, relative gravity; non gravity is the vacuum force. Gravity is centripetal, is a trend that the objects who attracted wants to Centripetal, or have been do Centripetal movement. Any object moves, so gravity makes the object curve movement, that is to say, the radiation range curve movement must be in the gravitational objects, gravity must be existed in non vacuum region, and make the object who is in the region of do curve movement (for example: The earth moves around the sun), or final attracted in the form gravitational objects, and keep relatively static with attract object. (for example: objects on the earth moves but can't reach the first cosmic speed).

  1. Ultrasound-Guided Percutaneous Catheter Drainage of Large Breast Abscesses in Lactating Women: How to Preserve Breastfeeding Safely.

    PubMed

    Falco, Giuseppe; Foroni, Monica; Castagnetti, Fabio; Marano, Luigi; Bordoni, Daniele; Rocco, Nicola; Marchesi, Vanessa; Iotti, Valentina; Vacondio, Rita; Ferrari, Guglielmo

    2016-12-01

    Management of breast abscess in lactating women remains controversial. During pregnancy, women may develop different kinds of benign breast lesions that could require a surgical incision performed under general anesthesia with consequent breastfeeding interruption. The purpose of this study was to prospectively evaluate the management of large breast abscesses with ultrasound-assisted drainage aiming at breastfeeding preservation. 34 lactating women with a diagnosis of unilateral breast abscess have been treated with an ultrasound (US)-assisted drainage of the abscess. A pigtail catheter was inserted into the fluid collection using the Seldinger technique under US guide and connected to a three stop way to allow drainage and irrigation of the cavity until its resolution. All procedures have been found safe and well tolerated. No recurrence was observed and breastfeeding was never interrupted. The described technique allows to avoid surgery and to preserve breastfeeding in well-selected patients with a safe, well-tolerated and cost-effective procedure.

  2. Ambient Profiling of Phenolic Content in Tea Infusions by Matrix-Assisted Ionization in Vacuum

    NASA Astrophysics Data System (ADS)

    Cody, Robert B.

    2018-05-01

    Matrix-assisted ionization in vacuum (MAIV) was used to analyze the polyphenol content of ten different tea infusions. Nine different Camellia sinensis infusions were analyzed including three green teas, two black teas, two oolong teas, jasmine tea, and white tea. An infusion of rooibos (Aspalathus linearis) tea was also analyzed. Each freshly brewed tea was diluted 1:1 with methanol, and 100 ppm of phenolphthalein was added as an internal standard. An excess of 3-nitrobenzonitrile (NBN) was added to each vial, and the solution containing NBN crystals was analyzed by aspiration directly into the mass spectrometer sampling orifice. A working curve constructed for dilutions of catechin with phenolphthalein internal standard showed good linearity for five replicates of each concentration. The measured relative abundances of flavonoid polyphenols in each tea were in good agreement with previously reported values. Polyphenol content in tea infusions varied from 19.2 to 108.6 mg 100 mL-1. In addition to the expected catechin flavonoids, abundant quinic acid and gallic acid was detected in the C. sinensis infusions. Characteristic A. linearis flavonoids were detected in the rooibos tea.

  3. Sinus venosus syndrome: atrial septal defect or anomalous venous connection? A multiplane transoesophageal approach.

    PubMed

    Oliver, J M; Gallego, P; Gonzalez, A; Dominguez, F J; Aroca, A; Mesa, J M

    2002-12-01

    To discuss the anatomical features of sinus venosus atrial defect on the basis of a comprehensive transoesophageal echocardiography (TOE) examination and its relation to surgical data. 24 patients (13 men, 11 women, mean (SD) age 37 (17) years, range 17-73 years) with a posterior interatrial communication closely related to the entrance of the superior (SVC) or inferior vena cava (IVC) who underwent TOE before surgical repair. Records of these patients were retrospectively reviewed and compared with surgical assessments. In 13 patients, TOE showed a deficiency in the extraseptal wall that normally separates the left atrium and right upper pulmonary vein from the SVC and right atrium. This deficiency unroofed the right upper pulmonary vein, compelling it to drain into the SVC, which overrode the intact atrial septum. In three patients, TOE examination showed a defect in the wall of the IVC, which continued directly into the posterior border of the left atrium. Thus, the intact muscular border of the atrial septum was overridden by the mouth of the IVC, which presented a biatrial connection. In the remaining eight patients, the defect was located in the muscular posterior border of the fossa ovalis. A residuum of atrial septum was visualised in the superior margin of the defect. Neither caval vein overriding nor anomalous pulmonary vein drainage was present. Sinus venosus syndrome should be regarded as an anomalous venous connection with an interatrial communication outside the confines of the atrial septum, in the unfolding wall that normally separates the left atrium from either caval vein. It results in overriding of the caval veins across the intact atrial septum and partial pulmonary vein anomalous drainage. It should be differentiated from posterior atrial septal defect without overriding or anomalous venous connections.

  4. Sinus venosus syndrome: atrial septal defect or anomalous venous connection? A multiplane transoesophageal approach

    PubMed Central

    Oliver, J M; Gallego, P; Gonzalez, A; Dominguez, F J; Aroca, A; Mesa, J M

    2002-01-01

    Objective: To discuss the anatomical features of sinus venosus atrial defect on the basis of a comprehensive transoesophageal echocardiography (TOE) examination and its relation to surgical data. Methods: 24 patients (13 men, 11 women, mean (SD) age 37 (17) years, range 17–73 years) with a posterior interatrial communication closely related to the entrance of the superior (SVC) or inferior vena cava (IVC) who underwent TOE before surgical repair. Records of these patients were retrospectively reviewed and compared with surgical assessments. Results: In 13 patients, TOE showed a deficiency in the extraseptal wall that normally separates the left atrium and right upper pulmonary vein from the SVC and right atrium. This deficiency unroofed the right upper pulmonary vein, compelling it to drain into the SVC, which overrode the intact atrial septum. In three patients, TOE examination showed a defect in the wall of the IVC, which continued directly into the posterior border of the left atrium. Thus, the intact muscular border of the atrial septum was overridden by the mouth of the IVC, which presented a biatrial connection. In the remaining eight patients, the defect was located in the muscular posterior border of the fossa ovalis. A residuum of atrial septum was visualised in the superior margin of the defect. Neither caval vein overriding nor anomalous pulmonary vein drainage was present. Conclusions: Sinus venosus syndrome should be regarded as an anomalous venous connection with an interatrial communication outside the confines of the atrial septum, in the unfolding wall that normally separates the left atrium from either caval vein. It results in overriding of the caval veins across the intact atrial septum and partial pulmonary vein anomalous drainage. It should be differentiated from posterior atrial septal defect without overriding or anomalous venous connections. PMID:12433899

  5. Central venous catheters: incidence and predictive factors of venous thrombosis.

    PubMed

    Hammes, Mary; Desai, Amishi; Pasupneti, Shravani; Kress, John; Funaki, Brian; Watson, Sydeaka; Herlitz, Jean; Hines, Jane

    2015-07-01

    Central venous catheter access in an acute setting can be a challenge given underlying disease and risk for venous thrombosis. Peripherally inserted central venous catheters (PICCs) are commonly placed but limit sites for fistula creation in patients with chronic renal failure (CKD). The aim of this study is to determine the incidence of venous thrombosis from small bore internal jugular (SBIJ) and PICC line placement. This investigation identifies populations of patients who may not be ideal candidates for a PICC and highlights the importance of peripheral vein preservation in patients with renal failure. A venous Doppler ultrasound was performed at the time of SBIJ insertion and removal to evaluate for thrombosis in the internal jugular vein. Data was collected pre- and post-intervention to ascertain if increased vein preservation knowledge amongst the healthcare team led to less use of PICCs. Demographic factors were collected in the SBIJ and PICC groups and risk factor analysis was completed. 1,122 subjects had PICC placement and 23 had SBIJ placement. The incidence of thrombosis in the PICC group was 10%. One patient with an SBIJ had evidence of central vein thrombosis when the catheter was removed. Univariate and multivariate analysis demonstrated a history of transplant, and the indication of total parenteral nutrition was associated with thrombosis (p<0.001). The decrease in PICCs placed in patients with CKD 6 months before and after intervention was significant (p<0.05). There are subsets of patients ith high risk for thrombosis who may not be ideal candidates for a PICC.

  6. Abdominal wall integrity after open abdomen: long-term results of vacuum-assisted wound closure and mesh-mediated fascial traction (VAWCM).

    PubMed

    Willms, A; Schaaf, S; Schwab, R; Richardsen, I; Bieler, D; Wagner, B; Güsgen, C

    2016-12-01

    The open abdomen has become a standard technique in the management of critically ill patients undergoing surgery for severe intra-abdominal conditions. Negative pressure and mesh-mediated fascial traction are commonly used and achieve low fistula rates and high fascial closure rates. In this study, long-term results of a standardised treatment approach are presented. Fifty-five patients who underwent OA management for different indications at our institution from 2006 to 2013 were enrolled. All patients were treated under a standardised algorithm that uses a combination of vacuum-assisted wound closure and mesh-mediated fascial traction. Structured follow-up assessments were offered to patients and included a medical history, a clinical examination and abdominal ultrasonography. The data obtained were statistically analysed. The fascial closure rate was 74 % in an intention-to-treat analysis and 89 % in a per-protocol analysis. The fistula rate was 1.8 %. Thirty-four patients attended follow-up. The median follow-up was 46 months (range 12-88 months). Incisional hernias developed in 35 %. Patients with hernias needed more operative procedures (10.3 vs 3.4, p = 0.03) than patients without hernia formation. A Patient Observer Scar Assessment Scale (POSAS) of 31.1 was calculated. Patients with symptomatic hernias (NAS of 2-10) had a significantly lower mean POSAS score (p = 0.04). Vacuum-assisted wound closure and mesh-mediated fascial traction (VAWCM) seem to result in low complication rates and high fascial closure rates. Abdominal wall reconstruction, which is a challenging and complex procedure and causes considerable patient discomfort, can thus be avoided in the majority of cases. Available results are based on studies involving only a small number of cases. Multi-centre studies and registry-based data are therefore needed to validate these findings.

  7. Chest Tube Drainage of the Pleural Space: A Concise Review for Pulmonologists.

    PubMed

    Porcel, José M

    2018-04-01

    Chest tube insertion is a common procedure usually done for the purpose of draining accumulated air or fluid in the pleural cavity. Small-bore chest tubes (≤14F) are generally recommended as the first-line therapy for spontaneous pneumothorax in non-ventilated patients and pleural effusions in general, with the possible exception of hemothoraces and malignant effusions (for which an immediate pleurodesis is planned). Large-bore chest drains may be useful for very large air leaks, as well as post-ineffective trial with small-bore drains. Chest tube insertion should be guided by imaging, either bedside ultrasonography or, less commonly, computed tomography. The so-called trocar technique must be avoided. Instead, blunt dissection (for tubes >24F) or the Seldinger technique should be used. All chest tubes are connected to a drainage system device: flutter valve, underwater seal, electronic systems or, for indwelling pleural catheters (IPC), vacuum bottles. The classic, three-bottle drainage system requires either (external) wall suction or gravity ("water seal") drainage (the former not being routinely recommended unless the latter is not effective). The optimal timing for tube removal is still a matter of controversy; however, the use of digital drainage systems facilitates informed and prudent decision-making in that area. A drain-clamping test before tube withdrawal is generally not advocated. Pain, drain blockage and accidental dislodgment are common complications of small-bore drains; the most dreaded complications include organ injury, hemothorax, infections, and re-expansion pulmonary edema. IPC represent a first-line palliative therapy of malignant pleural effusions in many centers. The optimal frequency of drainage, for IPC, has not been formally agreed upon or otherwise officially established. Copyright©2018. The Korean Academy of Tuberculosis and Respiratory Diseases.

  8. External jugular venous pressure as an alternative to conventional central venous pressure in right lobe donor hepatectomies.

    PubMed

    Abdullah, Mohamed Hussein; Soliman, Hossam El Deen; Morad, Wessam Saber

    2011-12-01

    Many centers have adopted central vein cannulation both for central venous pressure monitoring and fluid administration for right hepatectomy in living-liver donors. However, use of central venous catheters is associated with adverse events that are hazardous to patients and expensive to treat. This study sought to examine the use of external jugular venous pressure as an alternative to conventional central venous pressure in right lobe donor hepatectomies Forty ASA grade I adult living liver-donors without a known history of significant cardiac or pulmonary diseases were enrolled in this prospective observational study. Paired measurement of venous pressures (external jugular venous pressure and internal jugular venous pressure) were taken at the following times: after induction of anesthesia, 30 minutes after skin incision, during right lobe mobilization (every 15 minutes), during hepatic transaction (every 15 minutes), after right lobe resection (every 15 minutes), and after abdominal closure. Paired measurements were equal in 47.5%, 53.5%, 61.5%, 46.3%, and 52.5% for after induction, after skin incision, right lobe mobilization, right lobe transection, after resection, and before abdominal closure periods. However, all measurements were within acceptable limits of bias measurements (± 2 mm Hg). Central venous pressure catheter placement can be avoided and replaced by a less-invasive method such as external jugular venous pressure (which gave an acceptable estimate of central venous pressure in all phases of right lobe resection) in living-donor liver transplant and allowed equivalent monitor even during fluid restriction phases.

  9. Comparison of Oseltamivir and Oseltamivir Carboxylate Concentrations in Venous Plasma, Venous Blood, and Capillary Blood in Healthy Volunteers

    PubMed Central

    Instiaty, Insti; Lindegardh, Niklas; Jittmala, Podjanee; Hanpithakpong, Warunee; Blessborn, Daniel; Pukrittayakamee, Sasithon; White, Nicholas J.

    2013-01-01

    Oseltamivir and oseltamivir carboxylate concentrations were measured in venous plasma, venous blood, and capillary blood taken simultaneously from 24 healthy volunteers. Median (range) venous-blood-to-plasma ratios were 1.42 (0.920 to 1.97) for oseltamivir and 0.673 (0.564 to 0.814) for oseltamivir carboxylate. Capillary blood/venous plasma ratios were 1.32 (0.737 to 3.16) for oseltamivir and 0.685 (0.502 to 1.34) for oseltamivir carboxylate. Oseltamivir concentrations in venous and capillary blood were similar. Oseltamivir carboxylate showed a time-dependent distribution between venous and capillary blood. PMID:23507284

  10. Age differences in arterial and venous extra-cerebral blood flow in healthy adults: contributions of vascular risk factors and genetic variants.

    PubMed

    Raz, Naftali; Daugherty, Ana M; Sethi, Sean K; Arshad, Muzamil; Haacke, E Mark

    2017-08-01

    Sufficient cerebral blood flow (CBF) and venous drainage are critical for normal brain function, and their alterations can affect brain aging. However, to date, most studies focused on arterial CBF (inflow) with little attention paid to the age differences in venous outflow. We measured extra-cerebral arterial and venous blood flow rates with phase-contrast MRI and assessed the influence of vascular risk factors and genetic polymorphisms (ACE insertion/deletion, COMT val158met, and APOEε4) in 73 adults (age 18-74 years). Advanced age, elevated vascular risk, ACE Deletion, and COMT met alleles were linked to lower in- and outflow, with no effects of APOE ε4 noted. Lower age-related CBF rate was unrelated to brain volume and was observed only in val homozygotes of COMTval158met. Thus, in a disease-free population, age differences in CBF may be notable only in persons with high vascular risk and carriers of genetic variants associated with vasoconstriction and lower dopamine availability. It remains to be established if treatments targeting alleviation of the mutable factors can improve the course of cerebrovascular aging in spite of the immutable genetic influence.

  11. To what extent might deep venous thrombosis and chronic venous insufficiency share a common etiology?

    PubMed

    Malone, P Colm; Agutter, P S

    2009-08-01

    According to the valve cusp hypoxia hypothesis (VCHH), deep venous thrombosis is caused by sustained non-pulsatile (streamline) venous blood flow. This leads to hypoxemia in the valve pockets; hypoxic injury to the inner (parietalis) endothelium of the cusp leaflets activates the elk-1/egr-1 pathway, leading to leukocyte and platelet swarming at the site of injury and, potentially, blood coagulation. Here, we propose an extension of the VCHH to account for chronic venous insufficiency. First, should the foregoing events not proceed to frank thrombogenesis, the valves may nevertheless be chronically injured and become incompetent. Serial incompetence in lower limb valves may then generate ''passive'' venous hypertension. Second, should ostial valve thrombosis obstruct venous return from muscles via tributaries draining into the femoral vein, as Virchow illustrated, ''active'' venous hypertension may supervene: muscle contraction would force the blood in the vessels behind the blocked ostial valves to re-route. Passive or active venous hypertension opposes return flow, leading to luminal hypoxemia and vein wall distension, which in turn may impair vasa venarum perfusion; the resulting mural endothelial hypoxia would lead to leukocyte invasion of the wall and remodelling of the media. We propose that varicose veins result if gross active hypertension stretches the valve ''rings'', rendering attached valves incompetent caudad to obstructed sites, replacing normal centripetal flow in perforating veins with centrifugal flow and over-distending those vessels. We also discuss how hypoxemia-related venous/capillary wall lesions may lead to accumulation of leukocytes, progressive blockage of capillary blood flow, lipodermosclerosis and skin ulceration.

  12. Influence of bouncing and assisted autogenic drainage on acid gastro-oesophageal reflux in infants.

    PubMed

    Van Ginderdeuren, Filip; Vandenplas, Yvan; Deneyer, Michel; Vanlaethem, Sylvie; Buyl, Ronald; Kerckhofs, Eric

    2017-08-01

    To determine the influence of modern airway clearance techniques using assisted autogenic drainage (AAD), whether or not combined with bouncing, on acid gastro-oesophageal reflux (GOR) in infants <1 year. In this controlled trial with intra-subject design infants were studied using oesophageal pH monitoring over 24 h, during which they received one 15 min session of bouncing, AAD or bouncing combined with AAD (BAAD). The number of reflux episodes (RE) and the refluxindex (RI) were the outcome measures. The results obtained during (T15) and 15 min after the intervention (T30) were compared to a period of 15 min before treatment (T0). The results of 150 infants, evenly distributed over the three treatment groups, were analyzed. No significant differences were found in number of RE at T15 and T30 compared to T0 in the bouncing group (P = 0.42), the AAD group (P = 0.14), and the BAAD group (P = 0.91). RI was significantly lower in the AAD group at T15 compared to T0 (P < 0.01). No differences in RI were found in the bouncing group (P = 0.28), nor in the BAAD group (P = 0.81). Bouncing, AAD and BAAD do not induce, nor aggravate acid GOR in infants under the age of 1 year. © 2017 Wiley Periodicals, Inc.

  13. Novel approach to epicardial pacemaker implantation in patients with limited venous access.

    PubMed

    Costa, Roberto; Scanavacca, Mauricio; da Silva, Kátia Regina; Martinelli Filho, Martino; Carrillo, Roger

    2013-11-01

    Limited venous access in certain patients increases the procedural risk and complexity of conventional transvenous pacemaker implantation. The purpose of this study was to determine a minimally invasive epicardial approach using pericardial reflections for dual-chamber pacemaker implantation in patients with limited venous access. Between June 2006 and November 2011, 15 patients underwent epicardial pacemaker implantation. Procedures were performed through a minimally invasive subxiphoid approach and pericardial window with subsequent fluoroscopy-assisted lead placement. Mean patient age was 46.4 ± 15.3 years (9 male [(60.0%], 6 female [40.0%]). The new surgical approach was used in patients determined to have limited venous access due to multiple abandoned leads in 5 (33.3%), venous occlusion in 3 (20.0%), intravascular retention of lead fragments from prior extraction in 3 (20.0%), tricuspid valve vegetation currently under treatment in 2 (13.3%), and unrepaired intracardiac defects in 2 (13.3%). All procedures were successful with no perioperative complications or early deaths. Mean operating time for isolated pacemaker implantation was 231.7 ± 33.5 minutes. Lead placement on the superior aspect of right atrium, through the transverse sinus, was possible in 12 patients. In the remaining 3 patients, the atrial lead was implanted on the left atrium through the oblique sinus, the postcaval recess, or the left pulmonary vein recess. None of the patients displayed pacing or sensing dysfunction, and all parameters remained stable throughout the follow-up period of 36.8 ± 25.1 months. Epicardial pacemaker implantation through pericardial reflections is an effective alternative therapy for those patients requiring physiologic pacing in whom venous access is limited. © 2013 Heart Rhythm Society. All rights reserved.

  14. Cardiovascular and Interventional Radiological Society of Europe Commentary on the Treatment of Chronic Cerebrospinal Venous Insufficiency

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Reekers, J. A., E-mail: j.a.reekers@amc.uva.nl; Lee, M. J.; Belli, A. M.

    2011-02-15

    Chronic cerebrospinal venous insufficiency (CCSVI) is a putative new theory that has been suggested by some to have a direct causative relation with the symptomatology associated with multiple sclerosis (MS). The core foundation of this theory is that there is abnormal venous drainage from the brain due to outflow obstruction in the draining jugular vein and/or azygos veins. This abnormal venous drainage, which is characterised by special ultrasound criteria, called the 'venous hemodynamic insufficiency severity score' (VHISS), is said to cause intracerebral flow disturbance or outflow problems that lead to periventricular deposits. In the CCSVI theory, these deposits have amore » great similarity to the iron deposits seen around the veins in the legs in patients with chronic deep vein thrombosis. Zamboni, who first described this new theory, has promoted balloon dilatation to treat the outflow problems, thereby curing CCSVI and by the same token alleviating MS complaints. However, this theory does not fit into the existing bulk of scientific data concerning the pathophysiology of MS. In contrast, there is increasing worldwide acceptance of CCSVI and the associated balloon dilatation treatment, even though there is no supporting scientific evidence. Furthermore, most of the information we have comes from one source only. The treatment is called 'liberation treatment,' and the results of the treatment can be watched on YouTube. There are well-documented testimonies by MS patients who have gained improvement in their personal quality of life (QOL) after treatment. However, there are no data available from patients who underwent unsuccessful treatments with which to obtain a more balanced view. The current forum for the reporting of success in treating CCSVI and thus MS seems to be the Internet. At the CIRCE office and the MS Centre in Amsterdam, we receive approximately 10 to 20 inquiries a month about this treatment. In addition, many interventional radiologists

  15. Cerebral venous circulatory system evaluation by ultrasonography.

    PubMed

    Zavoreo, Iris; Basić-Kes, Vanja; Zadro-Matovina, Lucija; Lisak, Marijana; Corić, Lejla; Cvjeticanin, Timon; Ciliga, Dubravka; Bobić, Tatjana Trost

    2013-06-01

    Venous system can be classified as pulmonary veins, systemic veins and venous sinuses that are present only within the skull. Cerebral venous system is divided into two main parts, the superficial and the deep system. The main assignment of veins is to carry away deoxygenated blood and other maleficient materials from the tissues towards the heart. Veins have thinner walls and larger lumina than arteries. Between 60% and 70% of the total blood volume is found in veins. The major factors that influence venous function are the respiratory cycle, venous tone, the function of the right heart, gravity, and the muscle pump. Venous system, in general, can be presented by selective venography, Doppler sonography, computed tomography (CT) venography and magnetic resonance (MR) venography, and cerebral venous system can be displayed by selective venography, cerebral CT venography, cerebral MR venography, and specialized extracranial and transcranial Doppler sonography. The aim of this paper is to show the possibilities of intracranial and extracranial ultrasound evaluation of the head and neck venous circulation and chronic cerebrospinal venous insufficiency as one of the most common pathologies evaluated as part of neurodegenerative processes in the central nervous system.

  16. Sonographically-guided vacuum-assisted biopsy with digital mammography-guided skin marking of suspicious breast microcalcifications: comparison of outcomes with stereotactic biopsy in Asian women.

    PubMed

    Hahn, Soo Yeon; Shin, Jung Hee; Han, Boo-Kyung; Ko, Eun Young

    2011-02-01

    Management of suspicious microcalcifications in very thin breasts is problematic. To evaluate whether sonographically-guided vacuum-assisted biopsy (USVAB) with digital mammography-guided skin marking (DM) for the diagnosis of breast microcalcifications is comparable to stereotactic-guided vacuum-assisted biopsy (SVAB) in Asian women with thin breasts. Retrospective review was performed for 263 consecutive suspicious microcalcification lesions in 261 women who underwent USVAB with DM or SVAB using a prone table between January 2004 and December 2007. SVAB was performed for 190 lesions and USVAB for 73 lesions. Biopsy results were correlated with surgical pathology or followed up for at least 12 months. The diagnostic outcomes of SVAB and USVAB to diagnose microcalcifications were compared. Of 263 lesions, 104 (40%) underwent surgery and 159 (60%) were followed up. SVAB and USVAB groups showed similar final categories or the extent of microcalcifications. US visible lesions were 57 (78%) of 73 at USVAB and 14 (10%) of 140 at SVAB. Of 57 US visible lesions at USVAB, 29 (51%) were not found in initial US but were detectable with the help of DM. Specimen radiographs were negative in 2.1% of lesions at SVAB and in 4.1% at USVAB (p=0.4008). The under-estimation rate and false-negative rate were similar in SVAB and USVAB. US with DM facilitates US visibility of microcalcifications. USVAB with DM can produce acceptable biopsy results, as can SVAB, to diagnose breast microcalcifications in patients with thin breasts.

  17. Prairie Pothole Region wetlands and subsurface drainage systems: Key factors for determining drainage setback distances

    USGS Publications Warehouse

    Tangen, Brian; Wiltermuth, Mark T.

    2018-01-01

    Use of agricultural subsurface drainage systems in the Prairie Pothole Region of North America continues to increase, prompting concerns over potential negative effects to the Region's vital wetlands. The U.S. Fish and Wildlife Service protects a large number of wetlands through conservation easements that often utilize standard lateral setback distances to provide buffers between wetlands and drainage systems. Because of a lack of information pertaining to the efficacy of these setback distances for protecting wetlands, information is required to support the decision making for placement of subsurface drainage systems adjacent to wetlands. We used qualitative graphical analyses and data comparisons to identify characteristics of subsurface drainage systems and wetland catchments that could be considered when assessing setback distances. We also compared setback distances with catchment slope lengths to determine if they typically exclude drainage systems from the catchment. We demonstrated that depth of a subsurface drainage system is a key factor for determining drainage setback distances. Drainage systems located closer to the surface (shallow) typically could be associated with shorter lateral setback distances compared with deeper systems. Subsurface drainage systems would be allowed within a wetland's catchment for 44–59% of catchments associated with wetland conservation easements in North Dakota. More specifically, results suggest that drainage setback distances generally would exclude drainage systems from catchments of the smaller wetlands that typically have shorter slopes in the adjacent upland contributing area. For larger wetlands, however, considerable areas of the catchment would be vulnerable to drainage that may affect wetland hydrology. U.S. Fish and Wildlife Service easements are associated with > 2,000 km2 of wetlands in North Dakota, demonstrating great potential to protect these systems from drainage depending on policies for installing

  18. Agreement of arterial sodium and arterial potassium levels with venous sodium and venous potassium in patients admitted to intensive care unit.

    PubMed

    Nanda, Sunil Kumar; Ray, Lopamudra; Dinakaran, Asha

    2015-02-01

    Electrolyte abnormalities are one of the common causes of morbidity and mortality in critically ill patients. The turnaround time for electrolyte reporting should be as low as possible. Electrolytes are measured conventionally in serum obtained from venous blood by electrolyte analyser which takes 20 to 30 min. Point of care analysers are now available where in electrolytes can be measured in arterial blood within 5 min. This study was done to study the agreement of arterial sodium and arterial potassium with venous sodium and venous potassium levels. Venous sodium and venous potassium levels and arterial sodium and arterial potassium levels were analysed on 206 patient samples admitted to Intensive Care Unit (ICU). The venous values were compared with the arterial values for correlation. Venous sodium was compared with arterial sodium by spearman correlation. Venous potassium was compared with arterial potassium by pearson correlation. The mean value of arterial sodium was 134 and venous sodium was 137. The mean value of arterial potassium was 3.6 and venous potassium was 4.1. The correlation coefficient obtained for sodium was 0.787 and correlation coefficient obtained for potassium was 0.701. There was positive correlation of arterial sodium and arterial potassium with venous sodium and venous potassium indicating agreement between the parameters. Arterial sodium and arterial potassium can be used instead of venous sodium and venous potassium levels in management of critically ill patients.

  19. A vacuum microgripping tool with integrated vibration releasing capability

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Rong, Weibin; Fan, Zenghua, E-mail: zenghua-fan@163.com; Wang, Lefeng

    2014-08-01

    Pick-and-place of micro-objects is a basic task in various micromanipulation demands. Reliable releasing of micro-objects is usually disturbed due to strong scale effects. This paper focuses on a vacuum micro-gripper with vibration releasing functionality, which was designed and assembled for reliable micromanipulation tasks. Accordingly, a vibration releasing strategy of implementing a piezoelectric actuator on the vacuum microgripping tool is presented to address the releasing problem. The releasing mechanism was illustrated using a dynamic micro contact model. This model was developed via theoretical analysis, simulations and pull-off force measurement using atomic force microscopy. Micromanipulation experiments were conducted to verify the performancemore » of the vacuum micro-gripper. The results show that, with the assistance of the vibration releasing, the vacuum microgripping tool can achieve reliable release of micro-objects. A releasing location accuracy of 4.5±0.5 μm and a successful releasing rate of around 100% (which is based on 110 trials) were achieved for manipulating polystyrene microspheres with radius of 35–100 μm.« less

  20. Combined oral contraceptives: venous thrombosis.

    PubMed

    de Bastos, Marcos; Stegeman, Bernardine H; Rosendaal, Frits R; Van Hylckama Vlieg, Astrid; Helmerhorst, Frans M; Stijnen, Theo; Dekkers, Olaf M

    2014-03-03

    Combined oral contraceptive (COC) use has been associated with venous thrombosis (VT) (i.e., deep venous thrombosis and pulmonary embolism). The VT risk has been evaluated for many estrogen doses and progestagen types contained in COC but no comprehensive comparison involving commonly used COC is available. To provide a comprehensive overview of the risk of venous thrombosis in women using different combined oral contraceptives. Electronic databases (Pubmed, Embase, Web of Science, Cochrane, CINAHL, Academic Search Premier and ScienceDirect) were searched in 22 April 2013 for eligible studies, without language restrictions. We selected studies including healthy women taking COC with VT as outcome. The primary outcome of interest was a fatal or non-fatal first event of venous thrombosis with the main focus on deep venous thrombosis or pulmonary embolism. Publications with at least 10 events in total were eligible. The network meta-analysis was performed using an extension of frequentist random effects models for mixed multiple treatment comparisons. Unadjusted relative risks with 95% confidence intervals were reported.Two independent reviewers extracted data from selected studies. 3110 publications were retrieved through a search strategy; 25 publications reporting on 26 studies were included. Incidence of venous thrombosis in non-users from two included cohorts was 0.19 and 0.37 per 1 000 person years, in line with previously reported incidences of 0,16 per 1 000 person years. Use of combined oral contraceptives increased the risk of venous thrombosis compared with non-use (relative risk 3.5, 95% confidence interval 2.9 to 4.3). The relative risk of venous thrombosis for combined oral contraceptives with 30-35 μg ethinylestradiol and gestodene, desogestrel, cyproterone acetate, or drospirenone were similar and about 50-80% higher than for combined oral contraceptives with levonorgestrel. A dose related effect of ethinylestradiol was observed for gestodene

  1. Chemical changes exhibited by latent fingerprints after exposure to vacuum conditions.

    PubMed

    Bright, Nicholas J; Willson, Terry R; Driscoll, Daniel J; Reddy, Subrayal M; Webb, Roger P; Bleay, Stephen; Ward, Neil I; Kirkby, Karen J; Bailey, Melanie J

    2013-07-10

    The effect of vacuum exposure on latent fingerprint chemistry has been evaluated. Fingerprints were analysed using a quartz crystal microbalance to measure changes in mass, gas chromatography mass spectrometry to measure changes in lipid composition and attenuated total reflection Fourier transform infrared spectroscopy (ATR-FTIR) to determine changes in the content of water, fatty acids and their esters after exposure to vacuum. The results are compared with samples aged under ambient conditions. It was found that fingerprints lose around 26% of their mass when exposed to vacuum conditions, equivalent to around 5 weeks ageing under ambient conditions. Further exposure to vacuum causes a significant reduction in the lipid composition of a fingerprint, in particular with the loss of tetradecanoic and pentadecanoic acid, that was not observed in ambient aged samples. There are therefore implications for sequence in which fingerprint development procedures (for example vacuum metal deposition) are carried out, as well as the use of vacuum based methods such as secondary ion mass spectrometry (SIMS) and matrix-assisted laser desorption ionisation (MALDI) in the study of fingerprint chemistry. Copyright © 2013. Published by Elsevier Ireland Ltd.

  2. Venous pump of the calf: a study of venous and muscular pressures.

    PubMed

    Alimi, Y S; Barthelemy, P; Juhan, C

    1994-11-01

    Little data are available concerning the relation between the muscular pumping mechanism and the variation of superficial and deep venous pressure during normal action of the calf pump; therefore we undertook this study to determine the pressure values in three compartments of the calf and in the deep and the superficial venous system and to establish correlation between muscular and venous pressure. Nine healthy young women with a mean age of 23 years (range 19 to 28 years) were examined. In the same calf, a muscular catheter was placed in the deep posterior compartment (DPC), in the superficial posterior compartment (SPC), and in the anterior tibial compartment (ATC), and a vascular catheter was placed in the popliteal vein and in the greater saphenous vein (GSV). The five lines of pressure were simultaneously recorded in the following situations: at rest, during Valsalva maneuver, foot flexion, and foot extension. The situation was studied with the patient in the following positions: decubitus, sitting, standing, and squatting. A final continuous recording was carried out after the patient had been walking for 5 minutes. Mean values with standard errors of muscular and venous pressure were established in each situation. At rest and during Valsalva maneuver, the muscular pressures did not vary, whereas venous pressures increased significantly when the patient was sitting and standing. On the other hand, squatting was associated with a rise in the muscular and vein pressures. Foot flexion entailed a significant increase in the ATC pressure and a rise in the GSV pressure, whereas foot extension caused the DPC pressure to rise without venous pressure modifications. Walking was associated with an alternating increase in the DPC, SPC, GSV and popliteal vein pressures when the foot was compressed to floor followed by a significant decrease when the foot pressure was released. The variations in the deep and superficial venous pressures when the patient is sitting and

  3. Initial Experience with a Wireless Ultrasound-Guided Vacuum-Assisted Breast Biopsy Device

    PubMed Central

    Choi, E-Ryung; Han, Boo-Kyung; Ko, Eun Sook; Ko, Eun Young; Choi, Ji Soo; Cho, Eun Yoon; Nam, Seok Jin

    2015-01-01

    Objective To determine the imaging characteristic of frequent target lesions of wireless ultrasound (US)-guided, vacuum-assisted breast biopsy (Wi-UVAB) and to evaluate diagnostic yield, accuracy and complication of the device in indeterminate breast lesions. Materials and Methods From March 2013 to October 2014, 114 women (age range, 29–76 years; mean age, 50.0 years) underwent Wi-UVAB using a 13-gauge needle (Mammotome Elite®; Devicor Medical Products, Cincinnati, OH, USA). In 103 lesions of 96 women with surgical (n = 81) or follow-up (n = 22) data, complications, biopsy procedure, imaging findings of biopsy targets and histologic results were reviewed. Results Mean number of biopsy cores was 10 (range 4–25). Nine patients developed moderate bleeding. All lesions were suspicious on US, and included non-mass lesions (67.0%) and mass lesions (33.0%). Visible calcifications on US were evident in 57.3% of the target lesions. Most of the lesions (93.2%) were nonpalpable. Sixty-six (64.1%) were malignant [ductal carcinoma in situ (DCIS) rate, 61%] and 12 were high-risk lesions (11.7%). Histologic underestimation was identified in 11 of 40 (27.5%). DCIS cases and in 3 of 9 (33.3%) high-risk lesions necessitating surgery. There was no false-negative case. Conclusion Wi-UVAB is very handy and advantageous for US-unapparent non-mass lesions to diagnose DCIS, especially for calcification cases. Histologic underestimation is unavoidable; still, Wi-UVAB is safe and accurate to diagnose a malignancy. PMID:26630136

  4. Anomalous pulmonary venous drainage of right lung to inferior vena cava ("scimitar syndrome"): clinical spectrum in older patients and role of surgery.

    PubMed

    Honey, M

    1977-10-01

    Six new cases of the "scimitar syndrome" are described. The anatomical and haemodynamic features of these and other reported cases are reviewed. Within the spectrum of the disorder there is a group of patients in whom the bronchopulmonary manifestations are relatively unimportant. In five of our patients there was a left-to-right shunt exceeding 2:1 and the anomalous pulmonary venous connection was corrected surgically. The presence or absence of an associated atrial septal defect may be difficult to establish but influences the choice of surgical technique. When the atrial septum is intact, the anomalous vein should be reimplanted if possible into the back of the left atrium; otherwise a pericardial or teflon patch can be used to redirect the anomalous venous return through an existing or created atrial septal defect to the left atrium.

  5. Venous ulcer review

    PubMed Central

    Bevis, Paul; Earnshaw, Jonothan

    2011-01-01

    Clinical question: What is the best treatment for venous ulcers? Results: Compression aids ulcer healing. Pentoxifylline can aid ulcer healing. Artificial skin grafts are more effective than other skin grafts in helping ulcer healing. Correction of underlying venous incompetence reduces ulcer recurrence. Implementation: Potential pitfalls to avoid are: Failure to exclude underlying arterial disease before application of compression.Unusual-looking ulcers or those slow to heal should be biopsied to exclude malignant transformation. PMID:21673869

  6. Bibliography for acid-rock drainage and selected acid-mine drainage issues related to acid-rock drainage from transportation activities

    USGS Publications Warehouse

    Bradley, Michael W.; Worland, Scott C.

    2015-01-01

    Acid-rock drainage occurs through the interaction of rainfall on pyrite-bearing formations. When pyrite (FeS2) is exposed to oxygen and water in mine workings or roadcuts, the mineral decomposes and sulfur may react to form sulfuric acid, which often results in environmental problems and potential damage to the transportation infrastructure. The accelerated oxidation of pyrite and other sulfidic minerals generates low pH water with potentially high concentrations of trace metals. Much attention has been given to contamination arising from acid mine drainage, but studies related to acid-rock drainage from road construction are relatively limited. The U.S. Geological Survey, in cooperation with the Tennessee Department of Transportation, is conducting an investigation to evaluate the occurrence and processes controlling acid-rock drainage and contaminant transport from roadcuts in Tennessee. The basic components of acid-rock drainage resulting from transportation activities are described and a bibliography, organized by relevant categories (remediation, geochemical, microbial, biological impact, and secondary mineralization) is presented.

  7. Hydrothorax after Central Venous Catheterization

    PubMed Central

    Rudge, C. J.; Bewick, M.; McColl, I.

    1973-01-01

    Three patients are described who developed hydrothorax as a complication of central venous catheterization. Respiratory distress associated with physical signs of fluid in the chest should arouse suspicion that the venous catheter has perforated the wall of the vein. The complications of central venous catheterization are reviewed and three cases of hydrothorax are presented. Comments on the prevention of these complications, their diagnosis and treatment if they occur, are made. ImagesFIG. 1FIG. 2 PMID:4717421

  8. Stormwater Drainage Wells

    EPA Pesticide Factsheets

    Provides information for identifying stormwater drainage wells, learn how to comply with regulations for storm water drainage wells, and how to reduce the threat to ground water from stormwater injection wells.

  9. The effect of vein repair on the risk of venous thromboembolic events: a review of more than 100 traumatic military venous injuries.

    PubMed

    Quan, Reagan W; Gillespie, David L; Stuart, Rory P; Chang, Audrey S; Whittaker, David R; Fox, Charles J

    2008-03-01

    The management of venous trauma remains controversial. Critics of venous repair have cited an increased incidence of associated venous thromboembolic events with this management. We analyzed the current treatment of wartime venous injuries in United States military personnel in an effort to answer this question. From December 1, 2001, to October 31, 2005, all United States casualties with named venous injuries were evaluated. A retrospective review of a clinical database was performed on demographics, mechanism of injury, associated injuries, treatment, outcomes, and venous thromboembolic events. Data were analyzed using the Fisher exact test, analysis of variance, and logarithmic transformation. During this 5-year period, 82 patients sustained 103 named venous injuries due to combat operations. All patients were male, with an average age of 27.9 years (range, 20.3-58.3 years). Blast injuries accounted for 54 venous injuries (65.9%), gunshot wounds for 25 (30.5%), and motor vehicle accidents for 3 (3.6%). The venous injury was isolated in 28 patients (34.1%), and 16 (19.5%) had multiple venous injuries. The venous injury in two patients was associated with acute phlegmasia, with fractures in 33 (40.2%), and 22 (28.1%) sustained neurologic deficits. Venous injuries were treated by ligation in 65 patients (63.1%) and by open surgical repair in 38 (36.9%). Postoperative extremity edema occurred in all patients irrespective of method of management. Thrombosis after venous repair occurred in six of the 38 cases (15.8%). Pulmonary emboli developed in three patients, one after open repair and two after ligation (P > .99). In the largest review of military venous trauma in more than three decades, we found no difference in the incidence of venous thromboembolic complications between venous injuries managed by open repair vs ligation. Blast injuries of the extremities have caused most of the venous injuries. Ligation is the most common modality of treatment in combat zones

  10. Urine drainage bags

    MedlinePlus

    ... this page: //medlineplus.gov/ency/patientinstructions/000142.htm Urine drainage bags To use the sharing features on this page, please enable JavaScript. Urine drainage bags collect urine. Your bag will attach ...

  11. A survey of the European Venous Forum on education and training in venous surgery and phlebology in Europe.

    PubMed

    Spanos, K; De Maeseneer, M; Nicolaides, A; Giannoukas, A D

    2015-04-01

    Venous training in Europe is lacking a formal curriculum among various specialties related to management of venous diseases. We conducted a survey in order to have a snapshot on the actual education and training level among physicians practicing currently venous surgery and phlebology in Europe. From April 7, 2014 to June 11, 2014 a survey was carried out using the Survey Monkey system, including 11 main questions covering all the domains of training and education in venous surgery and phlebology. The questionnaire was sent to all physicians included in the current mailing list of the European Venous Forum (EVF) and the Mediterranean League of Angiology and Vascular Surgery. Two questions were particularly addressed to those physicians who had attended the EVF hands-on workshop (HOW) at least once. The response rate was 24% (97/400) and 51.5% of them were practicing in a hospital service. Most responders were vascular surgeons (67.7%), followed by angiologists (19.4%). Only half of the responders felt as being competent to manage the whole spectrum of venous diseases successfully after completion of their training, while a few were able to perform endovenous ablations and even less more advanced venous interventions. Formal training in Duplex ultrasound was undertaken only in 55.2%. The majority suggested that a venous training program should be a separate part of their specialty rotation and should be organized at a national or European level, or even by a specific scientific society. Over 95% of those physicians who already participated in the EVF HOW considered the knowledge they acquired there as useful for their practice. There is currently an important need for more specialized venous training for all physicians involved in the diagnosis and management of venous diseases. Therefore all local, national and international initiatives should be encouraged to improve education in this field.

  12. Molecular Weight Cut-Off and Structural Analysis of Vacuum-Assisted Titania Membranes for Water Processing

    PubMed Central

    Abd Jalil, Siti Nurehan; Wang, David K.; Yacou, Christelle; Motuzas, Julius; Smart, Simon; Diniz da Costa, João C.

    2016-01-01

    This work investigates the structural formation and analyses of titania membranes (TM) prepared using different vacuum exposure times for molecular weight (MW) cut-off performance and oil/water separation. Titania membranes were synthesized via a sol-gel method and coated on macroporous alumina tubes followed by exposure to a vacuum between 30 and 1200 s and then calcined at 400 °C. X-ray diffraction and nitrogen adsorption analyses showed that the crystallite size and particle size of titania increased as a function of vacuum time. All the TM membranes were mesoporous with an average pore diameter of ~3.6 nm with an anatase crystal morphology. Water, glucose, sucrose, and polyvinylpyrrolidone with 40 and 360 kDa (PVP-40 kDa and PVP-360 kDa) were used as feed solutions for MW cut-off and hexadecane solution for oil filtration investigation. The TM membranes were not able to separate glucose and sucrose, thus indicating the membrane pore sizes are larger than the kinetic diameter of sucrose of 0.9 nm, irrespective of vacuum exposure time. They also showed only moderate rejection (20%) of the smaller PVP-40 kDa, however, all the membranes were able to obtain an excellent rejection of near 100% for the larger PVP-360 kDa molecule. Furthermore, the TM membranes were tested for the separation of oil emulsions with a high concentration of oil (3000 ppm), reaching high oil rejections of more than 90% of oil. In general, the water fluxes increased with the vacuum exposure time indicating a pore structural tailoring effect. It is therefore proposed that a mechanism of pore size tailoring was formed by an interconnected network of Ti–O–Ti nanoparticles with inter-particle voids, which increased as TiO2 nanoparticle size increased as a function of vacuum exposure time, and thus reduced the water transport resistance through the TM membranes. PMID:28774057

  13. Indian Vacuum Society: The Indian Vacuum Society

    NASA Astrophysics Data System (ADS)

    Saha, T. K.

    2008-03-01

    The Indian Vacuum Society (IVS) was established in 1970. It has over 800 members including many from Industry and R & D Institutions spread throughout India. The society has an active chapter at Kolkata. The society was formed with the main aim to promote, encourage and develop the growth of Vacuum Science, Techniques and Applications in India. In order to achieve this aim it has conducted a number of short term courses at graduate and technician levels on vacuum science and technology on topics ranging from low vacuum to ultrahigh vacuum So far it has conducted 39 such courses at different parts of the country and imparted training to more than 1200 persons in the field. Some of these courses were in-plant training courses conducted on the premises of the establishment and designed to take care of the special needs of the establishment. IVS also regularly conducts national and international seminars and symposia on vacuum science and technology with special emphasis on some theme related to applications of vacuum. A large number of delegates from all over India take part in the deliberations of such seminars and symposia and present their work. IVS also arranges technical visits to different industries and research institutes. The society also helped in the UNESCO sponsored post-graduate level courses in vacuum science, technology and applications conducted by Mumbai University. The society has also designed a certificate and diploma course for graduate level students studying vacuum science and technology and has submitted a syllabus to the academic council of the University of Mumbai for their approval, we hope that some colleges affiliated to the university will start this course from the coming academic year. IVS extended its support in standardizing many of the vacuum instruments and played a vital role in helping to set up a Regional Testing Centre along with BARC. As part of the development of vacuum education, the society arranges the participation of

  14. Assessment of the service performance of drainage system and transformation of pipeline network based on urban combined sewer system model.

    PubMed

    Peng, Hai-Qin; Liu, Yan; Wang, Hong-Wu; Ma, Lu-Ming

    2015-10-01

    In recent years, due to global climate change and rapid urbanization, extreme weather events occur to the city at an increasing frequency. Waterlogging is common because of heavy rains. In this case, the urban drainage system can no longer meet the original design requirements, resulting in traffic jams and even paralysis and post a threat to urban safety. Therefore, it provides a necessary foundation for urban drainage planning and design to accurately assess the capacity of the drainage system and correctly simulate the transport effect of drainage network and the carrying capacity of drainage facilities. This study adopts InfoWorks Integrated Catchment Management (ICM) to present the two combined sewer drainage systems in Yangpu District, Shanghai (China). The model can assist the design of the drainage system. Model calibration is performed based on the historical rainfall events. The calibrated model is used for the assessment of the outlet drainage and pipe loads for the storm scenario currently existing or possibly occurring in the future. The study found that the simulation and analysis results of the drainage system model were reliable. They could fully reflect the service performance of the drainage system in the study area and provide decision-making support for regional flood control and transformation of pipeline network.

  15. Vacuum-assisted decellularization: an accelerated protocol to generate tissue-engineered human tracheal scaffolds.

    PubMed

    Butler, Colin R; Hynds, Robert E; Crowley, Claire; Gowers, Kate H C; Partington, Leanne; Hamilton, Nicholas J; Carvalho, Carla; Platé, Manuela; Samuel, Edward R; Burns, Alan J; Urbani, Luca; Birchall, Martin A; Lowdell, Mark W; De Coppi, Paolo; Janes, Sam M

    2017-04-01

    Patients with large tracheal lesions unsuitable for conventional endoscopic or open operations may require a tracheal replacement but there is no present consensus of how this may be achieved. Tissue engineering using decellularized or synthetic tracheal scaffolds offers a new avenue for airway reconstruction. Decellularized human donor tracheal scaffolds have been applied in compassionate-use clinical cases but naturally derived extracellular matrix (ECM) scaffolds demand lengthy preparation times. Here, we compare a clinically applied detergent-enzymatic method (DEM) with an accelerated vacuum-assisted decellularization (VAD) protocol. We examined the histological appearance, DNA content and extracellular matrix composition of human donor tracheae decellularized using these techniques. Further, we performed scanning electron microscopy (SEM) and biomechanical testing to analyze decellularization performance. To assess the biocompatibility of scaffolds generated using VAD, we seeded scaffolds with primary human airway epithelial cells in vitro and performed in vivo chick chorioallantoic membrane (CAM) and subcutaneous implantation assays. Both DEM and VAD protocols produced well-decellularized tracheal scaffolds with no adverse mechanical effects and scaffolds retained the capacity for in vitro and in vivo cellular integration. We conclude that the substantial reduction in time required to produce scaffolds using VAD compared to DEM (approximately 9 days vs. 3-8 weeks) does not compromise the quality of human tracheal scaffold generated. These findings might inform clinical decellularization techniques as VAD offers accelerated scaffold production and reduces the associated costs. Copyright © 2017 The Authors. Published by Elsevier Ltd.. All rights reserved.

  16. Clinical features of venous insufficiency and the risk of venous thrombosis in older people.

    PubMed

    Engbers, Marissa J; Karasu, Alev; Blom, Jeanet W; Cushman, Mary; Rosendaal, Frits R; van Hylckama Vlieg, Astrid

    2015-11-01

    Venous thrombosis is common in older age, with an incidence of 0·5-1% per year in those aged >70 years. Stasis of blood flow is an important contributor to the development of thrombosis and may be due to venous insufficiency in the legs. The risk of thrombosis associated with clinical features of venous insufficiency, i.e., varicose veins, leg ulcers and leg oedema, obtained with a standardized interview was assessed in the Age and Thrombosis Acquired and Genetic risk factors in the Elderly (AT-AGE) study. The AT-AGE study is a case-control study in individuals aged 70 years and older (401 cases with a first-time venous thrombosis and 431 control subjects). We calculated odds ratios (ORs) and corresponding 95% confidence intervals (CI) adjusted for age, sex and study centre. Varicose veins and leg ulcer were associated with a 1·6-fold (95% CI 1·2-2·3) and 3·3-fold increased risk of thrombosis (95% CI 1·6-6·7), respectively, while the risk was increased 3·0-fold (95% CI 2·1-4·5) in the presence of leg oedema. The risk of thrombosis was highest when all three risk factors occurred simultaneously (OR: 10·5; 95% CI 1·3-86·1). In conclusion, clinical features of venous insufficiency, i.e., varicose veins, leg ulcers and leg oedema, are risk factors for venous thrombosis in older people. © 2015 John Wiley & Sons Ltd.

  17. Current concepts in repair of extremity venous injury.

    PubMed

    Williams, Timothy K; Clouse, W Darrin

    2016-04-01

    Extremity venous injury management remains controversial. The purpose of this communication is to offer perspective as well as experiential and technical insight into extremity venous injury repair. Available literature is reviewed and discussed. Historical context is provided. Indication, the decision process for repair, including technical conduct, is delineated. In particular, the authors' experiences in both civilian and wartime injury are used for perspective. Extremity venous injury repair was championed within data from the Vietnam Vascular Registry. However, patterns of extremity venous injury differ between combat and civilian settings. Since Vietnam, civilian descriptive series opine the benefits and potential complications associated with both venous injury repair and ligation. These surround extremity edema, chronic venous insufficiency, thromboembolism, and limb loss. Whereas no clear superiority in either approach has been identified to date, there appears to be no increased risk of pulmonary embolism or chronic venous changes with repair. Newer data from the wars in Iraq and Afghanistan and meta-analysis have reinforced this and also have suggested limb salvage benefit for extremity venous repair in combined arterial and venous injuries in modern settings. The patient's physiologic state and associated injury drive five triage categories suggesting vein injury management. Vein repair thrombosis occurs in a significant proportion, yet many recanalize and possibly have a positive impact on limb venous return. Further, early decompression favors reduced blood loss, acute edema, and inflammation, supporting collateral development. Large soft tissue injury minimizing collateral capacity increases the importance of repair. Constructs of repair are varied with modest differences in patency. Venous shunting is feasible, but specific roles remain nebulous. An aggressive posture toward extremity venous injury repair seems justified today because of the likely

  18. Subsurface drainage volume reduction with drainage water management: Case studies in Ohio, USA

    USDA-ARS?s Scientific Manuscript database

    One of the main contributors to poor water quality in the Mississippi River and aeral increase in the hypoxic zone in the Gulf of Mexico is intensive drainage of the cropland within the watershed. Controlled drainage has been demonstrated as an approach to curb totla drainage outflow and nutrient di...

  19. [Mechanism of vacuum sealing drainage therapy attenuating ischemia-reperfusion injury of skeletal muscle in rabbit].

    PubMed

    Wang, Xiang; Yang, Fan; Guan, Zhen; Wang, Dongfang; Bai, Xiangjun; Gao, Wei

    2016-04-01

    To investigate the mechanism of how vacuum sealing drainage (VSD) ameliorating ischemia reperfusion (I/R) injury in skeletal muscle I/R model. Thirty New Zealand white rabbits were divided into three groups: control (sham operation) group, I/R group, VSD+ I/R group.The ischemia of the left hind limb of the animal was induced by clamping the common femoral artery and vein. After 4 hours of ischemia, the clamp was removed and the hind limp underwent 6 hours reperfusion. VSD treated animals received the treatment at the beginning of reperfusion. The concentrations of myeloperoxidase (MPO), malondialdehyde (MDA), superoxide dismutase (SOD), catalase (CAT) and glutathione (GSH) in muscular tissues were assayed. HE stained pathological section was used to evaluate the degree of edema of muscular tissues, and the immunohistochemistry was used to detect the percentage of positive cells expressing high mobility group protein B1 (HMGB1). Q-RT-PCR and Western Blot were used to detect the mRNA levels and protein expression of HMGB1 in myocyte respectively. The experimental data was tested using variance analysis. The levels of inflammatory factors and antioxidant factors in muscular tissues were significantly different in the I/R group compared to the VSD group and control group (the levels of MPO in I/R group, I/R+ VSD group and control group were 0.91±0.22, 0.53±0.08, 0.31±0.10, respectively, F=26.48, P=0.000; MDA were 2.04±0.92, 1.65±1.02, 1.01±0.12, F=4.250, P=0.040; SOD were 35.97±9.23, 55.99±18.97, 61.83±14.91, F=5.240, P=0.020; CAT were 31.42±16.27, 48.50±17.86, 75.95±13.09, F=9.720, P=0.002; GSH were 1.48±0.90, 3.54±1.88, 3.84±2.08, F=5.240, P=0.020). HE staining showed an increased intercellular space ratio in the I/R group (F=16.47, P<0.05). Immunohistochemistry staining showed that percentage of HMGB1 positive myocytes in control, I/R and I/R+ VSD group are 1.94%, 18.63% and 61.36%, respectively. There was significant difference among groups (F=853

  20. 21 CFR 870.1140 - Venous blood pressure manometer.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... 21 Food and Drugs 8 2014-04-01 2014-04-01 false Venous blood pressure manometer. 870.1140 Section... (CONTINUED) MEDICAL DEVICES CARDIOVASCULAR DEVICES Cardiovascular Diagnostic Devices § 870.1140 Venous blood pressure manometer. (a) Identification. A venous blood pressure manometer is a device attached to a venous...

  1. 21 CFR 870.1140 - Venous blood pressure manometer.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... 21 Food and Drugs 8 2012-04-01 2012-04-01 false Venous blood pressure manometer. 870.1140 Section... (CONTINUED) MEDICAL DEVICES CARDIOVASCULAR DEVICES Cardiovascular Diagnostic Devices § 870.1140 Venous blood pressure manometer. (a) Identification. A venous blood pressure manometer is a device attached to a venous...

  2. 21 CFR 870.1140 - Venous blood pressure manometer.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... 21 Food and Drugs 8 2013-04-01 2013-04-01 false Venous blood pressure manometer. 870.1140 Section... (CONTINUED) MEDICAL DEVICES CARDIOVASCULAR DEVICES Cardiovascular Diagnostic Devices § 870.1140 Venous blood pressure manometer. (a) Identification. A venous blood pressure manometer is a device attached to a venous...

  3. 21 CFR 870.1140 - Venous blood pressure manometer.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Venous blood pressure manometer. 870.1140 Section... (CONTINUED) MEDICAL DEVICES CARDIOVASCULAR DEVICES Cardiovascular Diagnostic Devices § 870.1140 Venous blood pressure manometer. (a) Identification. A venous blood pressure manometer is a device attached to a venous...

  4. Effects of quadratic coupling and squeezed vacuum injection in an optomechanical cavity assisted with a Bose-Einstein condensate

    NASA Astrophysics Data System (ADS)

    Dalafi, A.; Naderi, M. H.; Motazedifard, Ali

    2018-04-01

    We investigate theoretically a hybrid system consisting of a Bose-Einstein condensate (BEC) trapped inside a laser-driven membrane-in-the-middle optomechanical cavity assisted with squeezed vacuum injection whose moving membrane interacts both linearly and quadratically with the radiation pressure of the cavity. It is shown that such a hybrid system is very suitable for generating strong quadrature squeezing in the mechanical mode of the membrane and the Bogoliubov mode of the BEC in the unresolved sideband regime. More interestingly, by choosing a suitable sign for the quadratic optomechanical coupling (QOC), one can achieve a very high degree of squeezing in the mechanical mode and a strong entanglement between the mechanical and atomic modes without the necessity of using squeezed light injection. Furthermore, the QOC changes the effective oscillation frequencies of both the mechanical and the atomic modes and affects their relaxation times. It can also make the system switch from optical bistability to tristability.

  5. Human cerebral venous outflow pathway depends on posture and central venous pressure

    PubMed Central

    Gisolf, J; van Lieshout, J J; van Heusden, K; Pott, F; Stok, W J; Karemaker, J M

    2004-01-01

    Internal jugular veins are the major cerebral venous outflow pathway in supine humans. In upright humans the positioning of these veins above heart level causes them to collapse. An alternative cerebral outflow pathway is the vertebral venous plexus. We set out to determine the effect of posture and central venous pressure (CVP) on the distribution of cerebral outflow over the internal jugular veins and the vertebral plexus, using a mathematical model. Input to the model was a data set of beat-to-beat cerebral blood flow velocity and CVP measurements in 10 healthy subjects, during baseline rest and a Valsalva manoeuvre in the supine and standing position. The model, consisting of 2 jugular veins, each a chain of 10 units containing nonlinear resistances and capacitors, and a vertebral plexus containing a resistance, showed blood flow mainly through the internal jugular veins in the supine position, but mainly through the vertebral plexus in the upright position. A Valsalva manoeuvre while standing completely re-opened the jugular veins. Results of ultrasound imaging of the right internal jugular vein cross-sectional area at the level of the laryngeal prominence in six healthy subjects, before and during a Valsalva manoeuvre in both body positions, correlate highly with model simulation of the jugular cross-sectional area (R2 = 0.97). The results suggest that the cerebral venous flow distribution depends on posture and CVP: in supine humans the internal jugular veins are the primary pathway. The internal jugular veins are collapsed in the standing position and blood is shunted to an alternative venous pathway, but a marked increase in CVP while standing completely re-opens the jugular veins. PMID:15284348

  6. Occluded Brescia-Cimino Hemodialysis Fistulas: Endovascular Treatment with Both Brachial Arterial and Venous Access Using the Pull-Through Technique

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Miyayama, Shiro; Matsui, Osamu; Taki, Keiichi

    2005-12-15

    We retrospectively evaluated the usefulness of both arterial and venous access with the pull-through technique in endovascular treatment of totally occluded Brescia-Cimino fistulas. We treated 26 patients (17 men, 9 women; age range 43-82 years, mean age 66 years) with occluded Brescia-Cimino fistulas. First, the occluded segment was traversed from the antegrade brachial arterial access using a microcatheter-guidewire system. Second, the vein was retrogradely punctured after confirmation of all diseased segments, and a 0.014- or 0.016-inch guidewire was pulled through the venous access when the occluded segment was long. All interventions including thrombolysis, thromboaspiration, angioplasty, and stent placement were performedmore » via the venous access. The occlusion was successfully crossed via the brachial arterial access in 23 patients (88%). In 2 patients it was done from the venous approach. In the remaining patient it was not possible to traverse the occluded segment. The pull-through technique was successful in all 19 attempts. Clinical success was achieved in 96%, the primary patency rates at 6, 12, and 18 months were 83%, 78%, and 69%, the primary assisted patency rates were 92%, 92%, and 72%, and the secondary patency rates were 92%, 92%, and 92%, respectively. Minor complications in 5 patients included venous perforation in 2 (8%), venous rupture in 1 (4%), and regional hematoma in 2 (8%). Our study suggests that endovascular treatments with both arterial and venous access using the pull-through technique are highly effective in restoring function in totally occluded Brescia-Cimino fistulas.« less

  7. A failure of preoperative duplex imaging to diagnose a lower extremity venous aneurysm in a patient with severe chronic venous insufficiency.

    PubMed

    Jones, Roy Wesley; Parkerson, Godfrey Ross; Ottinger, Mary; Rodriguez, Eduardo; Park, Brian

    2017-01-01

    We present a case of recurrent bilateral lower extremity venous stasis ulcers in association with a superficial venous aneurysm at the right saphenofemoral junction that was misdiagnosed on preoperative duplex scanning. A 53-year-old female presented to our clinic with 6-year history of bilateral lower extremity venous stasis ulcers. Her past medical history was significant for refractory venous stasis ulcers of the bilateral lower extremities present for 6 years and morbid obesity. Preoperative venous duplex demonstrated severe venous insufficiency of the superficial and deep systems, but a venous aneurysm was not appreciated. During the high ligation of the right saphenofemoral junction, a 3 × 4 × 5 cm aneurysm was encountered. Repair consisted of aneurysm resection, high ligation of the greater saphenous vein, dissociation of the great saphenous and anterior saphenous veins, and stab phlebectomy of large varicose veins of the thigh and lower leg. The patient recovered uneventfully and experienced complete healing of the venous stasis ulcer in several weeks. Superficial venous aneurysms of the lower extremity are rare and can be often missed on preoperative duplex ultrasound imaging. Large diameter measurements of the proximal greater saphenous vein and obesity increase the risk of misdiagnosing venous aneurysms with duplex imaging; therefore, clinical suspicion must remain high. These aneurysms can be associated with significant symptoms for which repair is indicated.

  8. DEVELOPMENT AND OPTIMIZATION OF GAS-ASSISTED GRAVITY DRAINAGE (GAGD) PROCESS FOR IMPROVED LIGHT OIL RECOVERY

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Dandina N. Rao; Subhash C. Ayirala; Madhav M. Kulkarni

    This report describes the progress of the project ''Development and Optimization of Gas-Assisted Gravity Drainage (GAGD) Process for Improved Light Oil Recovery'' for the duration of the second project year (October 1, 2003--September 30, 2004). There are three main tasks in this research project. Task 1 is scaled physical model study of GAGD process. Task 2 is further development of vanishing interfacial tension (VIT) technique for miscibility determination. Task 3 is determination of multiphase displacement characteristics in reservoir rocks. In Section I, preliminary design of the scaled physical model using the dimensional similarity approach has been presented. Scaled experiments onmore » the current physical model have been designed to investigate the effect of Bond and capillary numbers on GAGD oil recovery. Experimental plan to study the effect of spreading coefficient and reservoir heterogeneity has been presented. Results from the GAGD experiments to study the effect of operating mode, Bond number and capillary number on GAGD oil recovery have been reported. These experiments suggest that the type of the gas does not affect the performance of GAGD in immiscible mode. The cumulative oil recovery has been observed to vary exponentially with Bond and capillary numbers, for the experiments presented in this report. A predictive model using the bundle of capillary tube approach has been developed to predict the performance of free gravity drainage process. In Section II, a mechanistic Parachor model has been proposed for improved prediction of IFT as well as to characterize the mass transfer effects for miscibility development in reservoir crude oil-solvent systems. Sensitivity studies on model results indicate that provision of a single IFT measurement in the proposed model is sufficient for reasonable IFT predictions. An attempt has been made to correlate the exponent (n) in the mechanistic model with normalized solute compositions present in both fluid

  9. [Learning curve of vacuum extraction in residency: a preliminary study].

    PubMed

    Velemir, L; Vendittelli, F; Bonnefoy, C; Accoceberry, M; Savary, D; Gallot, D

    2009-09-01

    The aim of this study was to assess the lurning curve of young residents for vacuum extraction. All vacuum extractions performed in our department by five residents (< or =5th semester) during a study period of nine months were systematically supervised by a senior who fulfilled an assessment questionnaire from which was calculated a score reflecting the quality of the extraction. Fifty-four vacuum extractions were assessed with a mean of 10.8+/-2.9 (range, 10-13) procedures by resident. We compared the group including the six first procedures performed by each resident (group 1, n = 30) with the group including the following procedures (group 2, n = 24). We observed in the group 2 compared to the group 1, a significant improvement of the scores mean (12.3+/-5.4 vs 8.4+/-6.2, p = 0.016) and a significant reduction of the need for manual assistance by the senior (12.5% vs 40%, p = 0.034). We report a method for the learning and assessment of vacuum extraction feasible at "the bed" of the patient. This approach allows to observe a significant progression of the resident for the technique of vacuum extraction on a dozen of procedures.

  10. Ultrasonic Spray Drying vs High Vacuum and Microwaves Technology for Blueberries

    NASA Astrophysics Data System (ADS)

    Candia-Muñoz, N.; Ramirez-Bunster, M.; Vargas-Hernández, Y.; Gaete-Garretón, L.

    Interest in high quality foods: good taste and a high content of nutrients with healthy beneficial effects are increasing. Fruits have good properties but, they are lost because the oxidation process, additionally, for different reasons a 40% of harvested fruit are lost. To conserve the fruit properties an ultrasonic assisted spray dryer was developed and tested, comparing its results with microwave-vacuum drying technology. Results did shown taste, color, smell, particle shape and size distribution better than the conventional one. The antioxidants conservation were quite good except in the anthocyanins, in which the microwave and vacuum technology shown best results.

  11. Venous thromboembolism: a UK perspective.

    PubMed

    Kakkar, Ajay

    2009-07-01

    Venous thromboembolism remains a significant cause of morbidity and mortality in the UK, and its dangers, particularly in hospitalized patients, have long been recognized. Recent measures to tackle this problem and new treatments should alleviate the burden of venous thromboembolism for patients, their families and hospital services.

  12. Venous thromboembolism and arterial complications.

    PubMed

    Prandoni, Paolo; Piovella, Chiara; Pesavento, Raffaele

    2012-04-01

    An increasing body of evidence suggests the likelihood of a link between venous and arterial thrombosis. The two vascular complications share several risk factors, such as age, obesity, smoking, diabetes mellitus, blood hypertension, hypertriglyceridemia, and metabolic syndrome. Moreover, there are many examples of conditions accounting for both venous and arterial thrombosis, such as the antiphospholipid antibody syndrome, hyperhomocysteinemia, malignancies, infections, and the use of hormonal treatment. Finally, several recent studies have consistently shown that patients with venous thromboembolism are at a higher risk of arterial thrombotic complications than matched control individuals. We, therefore, speculate the two vascular complications are simultaneously triggered by biological stimuli responsible for activating coagulation and inflammatory pathways in both the arterial and the venous system. Future studies are needed to clarify the nature of this association, to assess its extent, and to evaluate its implications for clinical practice. Thieme Medical Publishers 333 Seventh Avenue, New York, NY 10001, USA.

  13. Risk factors for upper extremity venous thrombosis associated with peripherally inserted central venous catheters.

    PubMed

    Marnejon, Thomas; Angelo, Debra; Abu Abdou, Ahmed; Gemmel, David

    2012-01-01

    To identify clinically important risk factors associated with upper extremity venous thrombosis following peripherally inserted central venous catheters (PICC). A retrospective case control study of 400 consecutive patients with and without upper extremity venous thrombosis post-PICC insertion was performed. Patient data included demographics, body mass index (BMI), ethnicity, site of insertion, size and lumen of catheter, internal length, infusate, and co-morbidities, such as diabetes mellitus, congestive heart failure, and renal failure. Additional risk factors analyzed were active cancer, any history of cancer, recent trauma, smoking, a history of prior deep vein thrombosis, and recent surgery, defined as surgery within three months prior to PICC insertion. The prevalence of trauma, renal failure, and infusion with antibiotics and total parenteral nutrition (TPN) was higher among patients exhibiting upper extremity venous thrombosis (UEVT), when compared to controls. Patients developing UEVT were also more likely to have PICC line placement in a basilic vein and less likely to have brachial vein placement (P<.001). Left-sided PICC line sites also posed a greater risk (P=.026). The rate of standard DVT prophylaxis with low molecular weight heparin and unfractionated heparin and the use of warfarin was similar in both groups. Average length of hospital stay was almost double among patients developing UEVT, 19.5 days, when compared to patients undergoing PICC line insertion without thrombosis, 10.8 days (t=6.98, P<.001). In multivariate analysis, trauma, renal failure, left-sided catheters, basilic placement, TPN, and infusion with antibiotics, specifically vancomycin, were significant risk factors for UEVT associated with PICC insertion. Prophylaxis with low molecular weight heparin, unfractionated heparin or use of warfarin did not prevent the development of venous thrombosis in patients with PICCs. Length of hospital stay and cost are markedly increased in

  14. Venous trauma in the Lebanon War--2006.

    PubMed

    Nitecki, Samy S; Karram, Tony; Hoffman, Aaron; Bass, Arie

    2007-10-01

    Reports on venous trauma are relatively sparse. Severe venous trauma is manifested by hemorrhage, not ischemia. Bleeding may be internal or external and rarely may lead to hypovolemic shock. Repair of major extremity veins has been a subject of controversy and the current teaching is to avoid venous repair in an unstable or multi-trauma patient. The aim of the current paper is to present our recent experience in major venous trauma during the Lebanon conflict, means of diagnosis and treatment in a level I trauma center. All cases of major venous trauma, either isolated or combined with arterial injury, admitted to the emergency room during the 33-day conflict were reviewed. Out of 511 wounded soldiers and civilians who were admitted to our service over this period, 12 (2.3%) sustained a penetrating venous injury either isolated (5) or combined with arterial injury (7). All injuries were secondary to high velocity penetrating missiles or from multiple pellets stored in long-range missiles. All injuries were accompanied by additional insult to soft tissue, bone and viscera. The mean injury severity score was 15. Severe external bleeding was the presenting symptom in three cases of isolated venous injury (jugular, popliteal and femoral). The diagnosis of a major venous injury was made by a CTA scan in five cases, angiography in one and during surgical exploration in six cases. All injured veins were repaired: three by venous interposition grafts, four by end to end anastomosis, three by lateral suture and two by endovascular techniques. None of the injuries was treated by ligation of a major named vein. Immediate postoperative course was uneventful in all patients and the 30-day follow-up (by clinical assessment and duplex scan) has demonstrated a patent repair with no evidence of thrombosis. Without contradicting the wisdom of ligating major veins in the setup of multi-trauma or an unstable patient, our experience indicates that a routine repair of venous trauma can

  15. Absence of inferior vena cava in 14-year old boy associated with deep venous thrombosis and positive Mycoplasma pneumoniae serum antibodies--a case report.

    PubMed

    Kalicki, Boleslaw; Sadecka, Monika; Wawrzyniak, Agata; Kozinski, Piotr; Dziekiewicz, Miroslaw; Jung, Anna

    2015-04-14

    Absence of the inferior vena cava is a rare vascular anomaly, which usually remains asymptomatic in childhood. It is recognized as the risk factor for deep venous thrombosis, since the collateral circulation does not provide adequate drainage of the lower limbs. Mycoplasma pneumoniae is a common cause of community-acquired pneumonia in school-aged children and adolescents. Mycoplasma pneumoniae infection might be associated with deep venous thrombosis but its pathophysiology remains unknown. According to previous reports, deep venous thrombosis due to Mycoplasma pneumoniae infection is associated with positive serum anticardiolipin antibodies. To our knowledge, we describe the first case of deep venous thrombosis associated with Mycoplasma pneumoniae serum antibodies indicating early stage of infection with negative anticardiolipin serum antibodies in adolescent with absence of inferior vena cava. 14-year old boy was admitted to the pediatric unit few days after the appendectomy complaining with pain of the left hip that caused him unable to walk. The pain was accompanied with subfebrile temperature. After clinical examination and additional tests, the boy was diagnosed with a deep venous thrombosis. Computed tomography revealed absence of the vena cava inferior distally to the hepatic veins and varices of the collateral circulation in the pelvis. Anticardiolipin IgM and IgG antibodies and antinuclear antibodies were not detected. Additionally, the Mycoplasma pneumoniae antibodies in classes IgM, IgA and IgG were detected in serum as another risk factor of thrombosis. After the initial treatment with low-molecular-weight heparin in combination with clarithromycin the clinical condition of the patient improved. The patient became a candidate for life-long anticoagulation therapy. In this case Mycoplasma pneumoniae antibodies were associated with deep venous thrombosis in child with congenital absence of inferior vena cava. Uncommonly for deep venous thrombosis due

  16. Optimizing Vacuum Assisted Resin Transfer Moulding (VARTM) Processing Parameters to Improve Part Quality

    NASA Astrophysics Data System (ADS)

    Polowick, Christopher

    The Low Cost Composites (LCC) group at Carleton University is studying out-of-autoclave composite manufacturing processes such as Vacuum Assisted Resin Transfer Moulding (VARTM) and Closed Cavity Bag Moulding (CCBM). These processes are used to produce inexpensive and high performance components for the GeoSurv II, an Unmanned Aerial Vehicle (UAV) being developed at Carleton University. This research has focused on optimizing VARTM processing parameters to reduce the weight and improve the strength and surface finish of GeoSurv II composite components. A simulation was developed to model resin flow through in VARTM infusions and was used to simulate mould filling and resin emptying of the GeoSurv II inverted V-empennage and mission avionics hatch. The resin infusion schemes of these parts were designed to ensure full preform resin saturation, and minimize thickness variations. An experimental study of the effects of the presence of a corner on composite thickness, void content, and strength was conducted. It was found that inside corners result in local increases in thickness and void content due to poor preform compaction. A novel bagging technique was developed to improve corner compaction, and this technique was shown to reduce thickness variability and void content. The strength, void content, and thickness variation were found to be heavily dependent on corner radius, with corner radii greater than 6.4 mm displaying the greatest improvement in performance for the layups considered. The design of the empennage and hatch mould incorporated the results of this study to improve the quality of these components.

  17. In-office drainage of sinus Mucoceles: An alternative to operating-room drainage.

    PubMed

    Barrow, Emily M; DelGaudio, John M

    2015-05-01

    Endoscopic drainage has become the standard of care for the treatment of mucoceles. In many patients this can be performed in the office. This study reviews our experience with in-office endoscopic mucocele drainage. Retrospective chart review. A retrospective review of one surgeon's experience with in-office endoscopic drainage of sinus mucoceles between 2006 and 2014 was performed. Charts were reviewed for patient demographics, previous surgery, mucocele location, bone erosion, and outcomes. Thirty-two patients underwent 36 in-office drainage procedures. All procedures were performed under topical/local anesthesia. The mean age was 55 years (range, 17-92 years). The mean follow-up time was 444 days. Fifty-five percent had previous sinus surgery. The primary sinus involved was the frontal (12), anterior (11), posterior ethmoid (six), maxillary (four), and sphenoid (two). Bone erosion was noted to be present on computed tomography in 18 mucoceles (51%) (16 orbital, seven skull-base). All mucoceles were successfully accessed in the office with the exception of one, which was aborted due to neo-osteogenesis. Five patients (14% of mucoceles) required additional surgery, two for mucocele recurrence and three for septated mucoceles not completely drained in the office. No treatment complications occurred. All but one patient preferred in-office to operating-room drainage. In-office drainage of sinus mucoceles is well tolerated by patients, with high success and low complication rates, even in large mucoceles with bone erosion. The presence of septations and neo-osteogenesis reduce the likelihood of complete drainage and are relative contraindications. Orbital and skull base erosion are not contraindications. 4. © 2014 The American Laryngological, Rhinological and Otological Society, Inc.

  18. Vacuum mechatronics

    NASA Technical Reports Server (NTRS)

    Hackwood, Susan; Belinski, Steven E.; Beni, Gerardo

    1989-01-01

    The discipline of vacuum mechatronics is defined as the design and development of vacuum-compatible computer-controlled mechanisms for manipulating, sensing and testing in a vacuum environment. The importance of vacuum mechatronics is growing with an increased application of vacuum in space studies and in manufacturing for material processing, medicine, microelectronics, emission studies, lyophylisation, freeze drying and packaging. The quickly developing field of vacuum mechatronics will also be the driving force for the realization of an advanced era of totally enclosed clean manufacturing cells. High technology manufacturing has increasingly demanding requirements for precision manipulation, in situ process monitoring and contamination-free environments. To remove the contamination problems associated with human workers, the tendency in many manufacturing processes is to move towards total automation. This will become a requirement in the near future for e.g., microelectronics manufacturing. Automation in ultra-clean manufacturing environments is evolving into the concept of self-contained and fully enclosed manufacturing. A Self Contained Automated Robotic Factory (SCARF) is being developed as a flexible research facility for totally enclosed manufacturing. The construction and successful operation of a SCARF will provide a novel, flexible, self-contained, clean, vacuum manufacturing environment. SCARF also requires very high reliability and intelligent control. The trends in vacuum mechatronics and some of the key research issues are reviewed.

  19. Percutaneous transfemoral repositioning of malpositioned central venous catheters.

    PubMed

    Hartnell, G G; Roizental, M

    1995-04-01

    Central venous catheters inserted by blind surgical placement may not advance into a satisfactory position and may require repositioning. Malpositioning via surgical insertion is common in patients in whom central venous catheters have previously been placed, as these patients are more likely to have central venous thrombosis and distortion of central venous anatomy. This is less of a problem when catheter placement is guided by imaging; however, even when insertion is satisfactory, central venous catheters may become displaced spontaneously after insertion (Fig. 1). Repositioning can be effected by direct manipulation using guidewires or tip-deflecting wires [1, 2], by manipulation via a transfemoral venous approach [3-5], and by injection of contrast material or saline [6]. Limitations of the direct approach include (1) the number and type of maneuvers that can be performed to effect repositioning when anatomy is distorted, (2) difficulty in accessing the catheter, and (3) the risk of introducing infection. Moreover, these patients are often immunosuppressed, and there is a risk of introducing infection by exposing and directly manipulating the venous catheter. Vigorous injection of contrast material or saline may be unsuccessful for the same reasons: It seldom exerts sufficient force to reposition large-caliber central venous catheters and may cause vessel damage or rupture if injection is made into a small or thrombosed vessel. We illustrate several alternative methods for catheter repositioning via a transfemoral venous approach.

  20. Drainage water management

    USDA-ARS?s Scientific Manuscript database

    This article introduces a series of papers that report results of field studies to determine the effectiveness of drainage water management (DWM) on conserving drainage water and reducing losses of nitrogen (N) to surface waters. The series is focused on the performance of the DWM (also called contr...

  1. Surgical management of venous malformations.

    PubMed

    Loose, D A

    2007-01-01

    Among vascular malformations, the predominantly venous malformations represent the majority of cases. They form a clinical entity and therefore need clear concepts concerning diagnosis and treatment. This paper presents an overview of contemporary classification as well as tactics and techniques of treatment. According to the Hamburg Classification, predominantly venous malformations are categorized into truncular and extratruncular forms, with truncular forms distinguished as obstructions and dilations, and extratruncular forms as limited or infiltrating. The tactics of treatment represent surgical and non-surgical methods or combined techniques. Surgical approaches utilize different tactics and techniques that are adopted based on the pathologic form and type of the malformation: (I) operation to reduce the haemodynamic activity of the malformation; (II) operation to eliminate the malformation; and (III) reconstructive operation. As for (I), a type of a tactic is the operation to derive the venous flow. In (II), the total or partial removal of the venous malformation is demonstrated subdivided into three different techniques. In this way, the infiltrating as well as the limited forms can be treated. An additional technique is dedicated to the treatment of a marginal vein. Approach (III) involves the treatment of venous aneurysms, where a variety of techniques have been successful. Long-term follow-up demonstrates positive results in 91% of the cases. Congenital predominantly venous malformations should be treated according to the principles developed during the past decades in vascular surgery, interventional treatment and multidisciplinary treatment. The days of predominantly conservative treatment should be relegated to the past. Special skills and experiences are necessary to carry out appropriate surgical strategy, and the required operative techniques should be dictated by the location and type of malformation and associated findings.

  2. Endoscopic vacuum therapy for various defects of the upper gastrointestinal tract.

    PubMed

    Kuehn, Florian; Loske, Gunnar; Schiffmann, Leif; Gock, Michael; Klar, Ernst

    2017-09-01

    Postoperative, iatrogenic or spontaneous upper gastrointestinal defects result in significant morbidity and mortality of the patients. In the last few years, endoscopic vacuum therapy (EVT) has been recognized as a new promising method for repairing upper gastrointestinal defects of different etiology. However, probably due to insufficient data and no commercially available system for EVT of the upper gastrointestinal tract, until the end of 2014, covering of esophageal defects with self-expanding metal stents (SEMS) were still the mainstay of endoscopic therapy. The aim of this article is to review the data available about EVT for various upper gastrointestinal defects. A selective literature search was conducted in Medline and PubMed (2007-2016), taking into account all the published case series and case reports reporting on the use of EVT in the management of upper gastrointestinal defects. EVT works through intracorporal application of negative pressure at the defect zone with an electronic controlled vacuum device along a polyurethane sponge drainage. This results in closure of the esophageal defect and internal drainage of the septic focus, simultaneously. Compared to stenting, EVT enables regular viewing of wound conditions with control of the septic focus and adjustment of therapy. Moreover, endoscopical negative pressure is applicable in all esophageal regions (cricopharygeal, tubular, gastroesophageal junction) and in anastomotic anatomic variants. EVT can be used solely as a definite treatment or as a complimentary therapy combined with operative revision. In total, there are published data of more than 200 patients with upper gastrointestinal defects treated with EVT, showing succes rates from 70-100%. The available data indicate that EVT is feasible, safe and effective with good short-term and long-term clinical outcomes in the damage control of upper GI-tract leaks. Still, a prospective multi-center study has to be conducted to proof the definite

  3. [Venous access in oncology].

    PubMed

    Lesimple, T; Béguec, J F; Levêque, J M

    1998-10-31

    Many treatments administered to cancer patients require venous access either via a peripheral vein or a larger central vein at the risk of local or systemic infection, thrombus formation or venous occlusion and dysfunction. Insertion of a central catheter is an invasive procedure which must be conducted under conditions of rigorous asepsia. Strict rules based on well-defined protocols must be applied throughout its use. Local or systemic infectious complications account for 18 to 25% of all nosocomial infections and are often related to colonisation of the puncture site by a Gram positive germ. In case of infection, ablation of the central catheter is not mandatory for diagnosis or antibiotic treatment. Reported at varying frequencies in the literature from 4 to 42%, thrombus formation is unpredictable and often difficult to diagnose. Anticoagulants or fibrolytic agents are indicated but it may also be necessary to withdraw the catheter. Displacement, rupture, obstruction and extravasation are frequent complications. Back flow must be checked in all venous accesses and free flow carefully verified. The access must remain patent throughout the period of use, guaranteed by a standard heparinization and rinsing protocol. This complications must not mask the important progress achieved with the use of central venous access for specific and symptomatic treatment in cancer patients.

  4. [One-stage operation for pelvis and acetabular fractures combined with Morel-Lavallée injury by internal fixation associated with vacuum sealing drainage].

    PubMed

    Wei, Dan; Wang, Yue; Yuan, Jiabin; Tang, Xiaoming; Zhang, Bin; Lu, Bing; Tan, Bo

    2014-01-01

    To investigate the methods and effectiveness of one-stage operation for pelvis and acetabular fractures combined with Morel-Lavallée injury by internal fixation associated with vacuum sealing drainage (VSD). Between June 2008 and October 2012, 15 cases of pelvis and acetabular fractures combined with Morel-Lavallée injury were treated. There were 5 males and 10 females, aged from 18 to 67 years (mean, 36.8 years). Fractures were caused by traffic accident in 11 cases and crashing injury of heavy object in 4 cases. The time from injury to hospitalization was 3 hours to 9 days (mean, 5.4 days). Morel-Lavallée injury located in the above posterior superior iliac spine in 4 cases, greater trochanter in 7 cases, and anterior proximal thigh in 4 cases. In 10 cases complicated by pelvic fracture, there were 1 case of anteroposterior compression type, 3 cases of lateral compression type, 5 cases of vertical shear type, and 1 case of compound injury type; in 5 cases complicated by acetabular fracture, there were 1 case of transverse fracture, 1 case of posterior wall and posterior column fracture, 1 case of transverse acetabulum plus posterior wall fracture, and 2 cases of both columns fracture. Open reduction and internal fixation were used to treat pelvic and acetabular fractures, and VSD to treat Morel-Lavallée injury. When the drainage volume was less than 20 mL/d, interrupted wound suture or free skin grafting was performed. The hospitalization time was 16-31 days (mean, 20.8 days). Thirteen cases were followed up 4-16 months (mean, 7.8 months). The healing time of Morel-Lavallée injury was 16-36 days after operation (mean, 21.3 days). All the wounds had primary healing, and no infection occurred. The X-ray films showed that all fractures healed, with a mean healing time of 13.6 weeks (range, 11-18 weeks). At 6.5 months after operation, according to Majeed function scoring system in 8 cases of pelvic fracture, the results were excellent in 5 cases, good in 2 cases

  5. Cannulation for veno-venous extracorporeal membrane oxygenation

    PubMed Central

    2018-01-01

    Extracorporeal membrane oxygenation (ECMO) is described as a modified, smaller cardiopulmonary bypass circuit. The veno-venous (VV) ECMO circuit drains venous blood, oxygenate the blood, and pump the blood back into the same venous compartment. Draining and reinfusing in the same compartment means there are a risk of recirculation. The draining position within the venous system, ECMO pump flow, return flow position within the venous system and the patients cardiac output (CO) all have an impact on recirculation. Using two single lumen cannulas or one dual lumen cannula, but also the design of the venous cannula, can have an impact on where within the venous system the cannula is draining blood and will affect the efficiency of the ECMO circuit. VV ECMO can be performed with different cannulation strategies. The use of two single lumen cannulas draining in inferior vena cava (IVC) and reinfusing in superior vena cava (SVC) or draining in SVC and reinfusing in IVC, or one dual lumen cannula inserted in right jugular vein is all possible cannulation strategies. Independent of cannulation strategy there will be a risk of recirculation. Efficiency can be reasonable in either strategy if the cannulas are carefully positioned and monitored during the dynamic procedure of pulmonary disease. The disadvantage draining from IVC only occurs when there is a need for converting from VV to veno-arterial (VA) ECMO, reinfusing in the femoral artery. Then draining from SVC is the most efficient strategy, draining low saturated venous blood, and also means low risk of dual circulation. PMID:29732177

  6. Intracranial venous sinus thrombosis as a complication of otitis media in children: Critical review of diagnosis and management.

    PubMed

    Zanoletti, Elisabetta; Cazzador, Diego; Faccioli, Chiara; Sari, Marianna; Bovo, Roberto; Martini, Alessandro

    2015-12-01

    Otogenic lateral sinus thrombosis (LST) is a rare intracranial complication of acute otitis media (AOM), which can lead to severe neurological sequelae and death. The aim of this study was to analyze the clinical presentation, management and outcome of LST in children, investigating a possible correlation between clinical aspects, radiological findings and anatomical variations. At a tertiary Italian hospital, a retrospective review was conducted on the medical records of eight patients diagnosed with otogenic LST over a 3-year period. Four children were males and mean age was 4.7 years. All patients had a history of otitis media at diagnosis and 4/8 presented also with more than one neurological sign or symptom. Mastoiditis signs were detected in 5/8 patients. Thrombosis was diagnosed by computed tomography, enhanced magnetic resonance and magnetic resonance venography. Treatment was medical, alone or combined with surgery. Medical treatment consisted in anticoagulants eventually combined with anti-edema medication on clinical basis. Mastoidectomy and/or myringotomy±trans-tympanic drainage placement were performed in 7/8 patients. Complete vessel recanalization was obtained in 6/8 children after a median follow-up time of 4.8 months. No complications, neither clinical sequelae occurred. In our series, neurological signs and symptoms were significantly associated with the presence of hypoplasia of the contralateral venous sinus (p=0.029). LST is a severe condition occurring even in absence of otological signs, and despite adequate antibiotic therapy for AOM, which should be ruled out and promptly treated. A dominant neurological presentation is associated in our series with anatomical variations of cerebral sinus venous drainage patterns. This should be carefully evaluated and considered in diagnosis, treatment planning and prognosis. Copyright © 2015 Elsevier Ireland Ltd. All rights reserved.

  7. Natural vacuum electronics

    NASA Technical Reports Server (NTRS)

    Leggett, Nickolaus

    1990-01-01

    The ambient natural vacuum of space is proposed as a basis for electron valves. Each valve is an electron controlling structure similiar to a vacuum tube that is operated without a vacuum sustaining envelope. The natural vacuum electron valves discussed offer a viable substitute for solid state devices. The natural vacuum valve is highly resistant to ionizing radiation, system generated electromagnetic pulse, current transients, and direct exposure to space conditions.

  8. Effects of parasagittal meningiomas on intracranial venous circulation assessed by the virtual reality technology.

    PubMed

    Wang, Shousen; Ying, Jianbin; Wei, Liangfeng; Li, Shiqing; Jing, Junjie

    2015-01-01

    This study is to investigate the compensatory intracranial venous pathways in parasagittal meningiomas (PSM) patients by virtual reality technology. A total of 48 PSM patients (tumor group) and 20 patients with trigeminal neuralgia and hemifacial spasm but without intracranial venous diseases (control group) were enrolled. All patients underwent 3D CE-MRV examination. The 3D reconstructed images by virtual reality technology were used for assessment of diameter and number of intracranial veins, tumor location, venous sinus invasion degree and collateral circulation formation. Diameter of bridging veins in posterior 1/3 superior sagittal sinus (SSS) in tumor group was significantly smaller than that of the control group (P < 0.05). For tumors located in mid 1/3 SSS, diameter of bridging veins and vein of Labbé (VL) in posterior 1/3 SSS decreased significantly (P < 0.05). For tumors located in posterior 1/3 SSS, bridging vein number and transverse sinus (TS) diameter significantly decreased while superficial Sylvian vein (SSV) diameter increased significantly (P < 0.05). Compared with tumor in posterior 1/3 SSS subgroup, number of bridging veins in the tumor in mid 1/3 SSS subgroup increased significantly (P < 0.05). Compared with control group, only the bridging vein number in anterior 1/3 SSS segment in invasion Type 3-4 tumor subgroup decreased significantly (P < 0.05). Diameter of TS and bridging veins in posterior 1/3 SSS segment in sinus invasion Type 5-6 tumor subgroup decreased significantly (P < 0.05). Compared with control group, only the diameter of VL and TS of collateral circulation Grade 1 tumor subgroup decreased significantly (P < 0.05) while in Grade 3 tumor subgroup, TS diameter decreased and SSV diameter increased significantly (P < 0.05). The intracranial blood flow is mainly drained through SSV drainage after SSS occlusion by PSM.

  9. Effects of parasagittal meningiomas on intracranial venous circulation assessed by the virtual reality technology

    PubMed Central

    Wang, Shousen; Ying, Jianbin; Wei, Liangfeng; Li, Shiqing; Jing, Junjie

    2015-01-01

    Objective: This study is to investigate the compensatory intracranial venous pathways in parasagittal meningiomas (PSM) patients by virtual reality technology. Methods: A total of 48 PSM patients (tumor group) and 20 patients with trigeminal neuralgia and hemifacial spasm but without intracranial venous diseases (control group) were enrolled. All patients underwent 3D CE-MRV examination. The 3D reconstructed images by virtual reality technology were used for assessment of diameter and number of intracranial veins, tumor location, venous sinus invasion degree and collateral circulation formation. Results: Diameter of bridging veins in posterior 1/3 superior sagittal sinus (SSS) in tumor group was significantly smaller than that of the control group (P < 0.05). For tumors located in mid 1/3 SSS, diameter of bridging veins and vein of Labbé (VL) in posterior 1/3 SSS decreased significantly (P < 0.05). For tumors located in posterior 1/3 SSS, bridging vein number and transverse sinus (TS) diameter significantly decreased while superficial Sylvian vein (SSV) diameter increased significantly (P < 0.05). Compared with tumor in posterior 1/3 SSS subgroup, number of bridging veins in the tumor in mid 1/3 SSS subgroup increased significantly (P < 0.05). Compared with control group, only the bridging vein number in anterior 1/3 SSS segment in invasion Type 3-4 tumor subgroup decreased significantly (P < 0.05). Diameter of TS and bridging veins in posterior 1/3 SSS segment in sinus invasion Type 5-6 tumor subgroup decreased significantly (P < 0.05). Compared with control group, only the diameter of VL and TS of collateral circulation Grade 1 tumor subgroup decreased significantly (P < 0.05) while in Grade 3 tumor subgroup, TS diameter decreased and SSV diameter increased significantly (P < 0.05). Conclusions: The intracranial blood flow is mainly drained through SSV drainage after SSS occlusion by PSM. PMID:26550184

  10. Venous hemostasis postcatheter ablation of atrial fibrillation while under therapeutic levels of oral and intravenous anticoagulation.

    PubMed

    Issa, Ziad F; Amr, Bashar S

    2015-11-01

    Catheter ablation of atrial fibrillation (AF) requires utilizing multiple venous femoral sheaths in conjunction with aggressive periprocedural anticoagulation, which can lead to increased risk of vascular access complications. The objective of this study is to evaluate the safety and efficacy of the "figure-of-eight" ("F-8") suture technique for femoral venous hemostasis while on therapeutic doses of intravenous anticoagulation at the time of sheath removal. In this case-control analysis, 376 consecutive patients underwent AF ablation while on uninterrupted oral anticoagulation and received intraprocedural heparin. In the first 253 patients (the control group), manual pressure was used for femoral venous hemostasis after reversal of heparin effects. The subsequent 123 patients (the F-8 group) had femoral venous hemostasis using the F-8 suture technique and while under therapeutic heparin effects. The F-8 subcutaneous suture technique achieved adequate venous hemostasis in 98.4% of patients. As compared to the control group, there was significantly less frequent utilization of the FemoStop compression assist device (1.2 vs. 16.8%, p < 0.0001) and in a significantly shorter interval (6.8 ± 5.7 vs. 50.7 ± 12.2 min, p < 0.0001). Vascular access complications and thromboembolic events occurred in 9.8% in the F-8 group vs. 13.0% in the control group (p = 0.678). Immediate hemostasis of the femoral venous access sites after insertion of multiple sheaths for AF ablation in the presence of anticoagulation can be safely and effectively achieved using the F-8 suture technique. This technique helps minimize the period of inadequate anticoagulation immediately following ablation and shortens the time required to achieve adequate hemostasis.

  11. Characterization of central venous catheter-associated deep venous thrombosis in infants.

    PubMed

    Gray, Brian W; Gonzalez, Raquel; Warrier, Kavita S; Stephens, Lauren A; Drongowski, Robert A; Pipe, Steven W; Mychaliska, George B

    2012-06-01

    Deep venous thrombosis (DVT) is a frequent complication in infants with central venous catheters (CVCs). We performed this study to identify risk factors and risk-reduction strategies of CVC-associated DVT in infants. Infants younger than 1 year who had a CVC placed at our center from 2005 to 2009 were reviewed. Patients with ultrasonically diagnosed DVT were compared to those without radiographic evidence. Of 333 patients, 47% (155/333) had femoral, 33% (111/333) had jugular, and 19% (64/333) had subclavian CVCs. Deep venous thromboses occurred in 18% (60/333) of patients. Sixty percent (36/60) of DVTs were in femoral veins. Femoral CVCs were associated with greater DVT rates (27%; 42/155) than jugular (11%; 12/111) or subclavian CVCs (9%; 6/64; P < .01). There was a 16% DVT rate in those with saphenofemoral Broviac CVCs vs 83% (20/24) in those with percutaneous femoral lines (P < .01). Multilumen CVCs had higher DVT rates than did single-lumen CVCs (54% vs 6%, P < .01), and mean catheter days before DVT diagnosis was shorter for percutaneous lines than Broviacs (13 ± 17 days vs 30 ± 37 days, P = .02). Patients with +DVT had longer length of stay (86 ± 88 days vs 48 ± 48 days, P < .01) and higher percentage of intensive care unit admission (82% vs 70%, P = .02). Deep venous thrombosis reduction strategies in infants with CVCs include avoiding percutaneous femoral and multilumen CVCs, screening percutaneous lines, and early catheter removal. Copyright © 2012 Elsevier Inc. All rights reserved.

  12. The possibility for use of venous flaps in plastic surgery

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Baytinger, V. F., E-mail: baitinger@mail.tomsknet.ru; Kurochkina, O. S., E-mail: kurochkinaos@yandex.ru; Selianinov, K. V.

    2015-11-17

    The use of venous flaps is controversial. The mechanism of perfusion of venous flaps is still not fully understood. The research was conducted on 56 white rats. In our experimental work we studied two different models of venous flaps: pedicled venous flap (PVF) and pedicled arterialized venous flap (PAVF). Our results showed that postoperative congestion was present in all flaps. However 66.7% of all pedicled venous flaps and 100% of all pedicled arterialized venous flaps eventually survived. Histological examination revealed that postoperatively the blood flow in the skin of the pedicled arterialized venous flap became «re-reversed» again; there were nomore » differences between mechanism of survival of venous flaps and other flaps. On the 7-14th day in the skin of all flaps were processes of neoangiogenesis and proliferation. Hence the best scenario for the clinical use of venous flaps unfolds when both revascularization and skin coverage are required.« less

  13. Primary prophylaxis of venous thromboembolism in children.

    PubMed

    Cole, Catherine H

    2010-06-01

    Venous thromboembolism (VTE) is rare in children and young adolescents, and occurs predominantly in those with congenital heart disease in whom guidelines exist for VTE prophylaxis. For other paediatric patients, the rarity of the event makes writing an evidence-based clinical practice guideline difficult because each of the known risk factors contributes only a small increase in risk. Thrombophilia screening is controversial because few results assist with prediction of likely thrombosis and may not alter recommendations for prophylaxis. Recent publications highlight the importance of non-pharmacological prevention of VTE in children and adolescents undergoing surgery and the importance of liaison among surgeon, anaesthetist and haematologist. This annotation was written with the aim of collating current evidence for VTE prophylaxis and emphasising the need for further research in vulnerable subgroups.

  14. Employment of physical therapist assistants in a residential state school.

    PubMed

    Lovelace-Chandler, V; Lovelace-Chandler, B

    1979-10-01

    Development of a job description for physical therapist assistants in a residential center serving persons with developmental disabilities is presented. Academic preparation and ethical guidelines for the assistant were reviewed to determine appropriate job responsibilities. Assistants had sufficient academic preparation in modalities and bronchial drainage to function effectively and partial academic preparation in other areas related to treating developmental disabilities. Substantial on-the-job training was necessary for the assistant to perform specific tasks competently. Need for additional training was not considered a deterrent to hiring the assistant.

  15. VACUUM TRAP

    DOEpatents

    Gordon, H.S.

    1959-09-15

    An improved adsorption vacuum trap for use in vacuum systems was designed. The distinguishing feature is the placement of a plurality of torsionally deformed metallic fins within a vacuum jacket extending from the walls to the central axis so that substantially all gas molecules pass through the jacket will impinge upon the fin surfaces. T fins are heated by direct metallic conduction, thereby ol taining a uniform temperature at the adeorbing surfaces so that essentially all of the condensible impurities from the evacuating gas are removed from the vacuum system.

  16. Drainage area data for Alabama streams

    USGS Publications Warehouse

    Stallings, J.S.; Peirce, L.B.

    1957-01-01

    The drainage area of a river basin is an important parameter in many engineering equations used for hydrologic design. It is not a parameter, however, that always requires precise measurement. Factors in the hydrologic cycle such as rainfall, runoff, transpiration, and infiltration cannot be measured nearly as closely as drainage area. Largely for this reason, drainage areas are often measured to varying degrees of precision depending upon the immediate need, with little thought to some other use or some other user of the figure obtained. It can readily be appreciated that this practice, continued for long by many different agencies, will result in a heterogeneous collection of drainage area figures, often discordant and of an accuracy unknown to any but those who computed them. Figures of drainage area published by various Federal agencies are frequently discrepant or contradictory, giving rise to confusion in the use of drainage area data. Seeking to better this situation, the Federal Inter-Agency River Basin Committee (FIARBC) in November 1951 published its Bulletin No. 4, Inter-Agency Coordination of Drainage Area Data. That Bulletin recommended procedures to be followed by the interested Federal agencies “for coordinating drainage area data in the interest of promoting uniformity, reducing confusion and contradiction of published figures, and improving the ready availability of drainage area data pertaining to drainage basins of the United States and its possessions.”

  17. Effect of hepatic venous sphincter contraction on transmission of central venous pressure to lobar and portal pressure.

    PubMed

    Lautt, W W; Legare, D J; Greenway, C V

    1987-11-01

    In dogs anesthetized with pentobarbital, central vena caval pressure (CVP), portal venous pressure (PVP), and intrahepatic lobar venous pressure (proximal to the hepatic venous sphincters) were measured. The objective was to determine some characteristics of the intrahepatic vascular resistance sites (proximal and distal to the hepatic venous sphincters) including testing predictions made using a recent mathematical model of distensible hepatic venous resistance. The stimulus used was a brief rise in CVP produced by transient occlusion of the thoracic vena cava in control state and when vascular resistance was elevated by infusions of norepinephrine or histamine, or by nerve stimulation. The percent transmission of the downstream pressure rise to upstream sites past areas of vascular resistance was elevated. Even small increments in CVP are partially transmitted upstream. The data are incompatible with the vascular waterfall phenomenon which predicts that venous pressure increments are not transmitted upstream until a critical pressure is overcome and then further increments would be 100% transmitted. The hepatic sphincters show the following characteristics. First, small rises in CVP are transmitted less than large elevations; as the CVP rises, the sphincters passively distend and allow a greater percent transmission upstream, thus a large rise in CVP is more fully transmitted than a small rise in CVP. Second, the amount of pressure transmission upstream is determined by the vascular resistance across which the pressure is transmitted. As nerves, norepinephrine, or histamine cause the hepatic sphincters to contract, the percent transmission becomes less and the distensibility of the sphincters is reduced. Similar characteristics are shown for the "presinusoidal" vascular resistance and the hepatic venous sphincter resistance.(ABSTRACT TRUNCATED AT 250 WORDS)

  18. Normal venous anatomy and physiology of the lower extremity.

    PubMed

    Notowitz, L B

    1993-06-01

    Venous disease of the lower extremities is common but is often misunderstood. It seems that the focus is on the exciting world of arterial anatomy and pathology, while the topic of venous anatomy and pathology comes in second place. However, venous diseases such as chronic venous insufficiency, leg ulcers, and varicose veins affect much of the population and may lead to disability and death. Nurses are often required to answer complex questions from the patients and his or her family about the patient's disease. Patients depend on nurses to provide accurate information in terms they can understand. Therefore it is important to have an understanding of the normal venous system of the legs before one can understand the complexities of venous diseases and treatments. This presents an overview of normal venous anatomy and physiology.

  19. [Non-invasive assessment of the perfusion of wounds using power Doppler imaging: vacuum assisted closure versus direct wound closure].

    PubMed

    Jungius, K P; Chilla, B K; Labler, L; Teodorovic, N; Marincek, B

    2006-10-01

    The goal of our study was to assess the perfusion in wounds treated by vacuum assisted closure (VAC) compared to primary wound closure. Power Doppler Ultrasound (PDUS) was carried out under standardised conditions in 15 VAC-treated and 10 primarily closed wounds as well as on altogether 25 intraindividual reference areas. All data were sent to a work station for post-processing to determine the perfused area. Statistical data analysis was performed with the Mann-Whitney test. Both VAC-treated wounds and primarily closed wounds showed a significant increase of the perfusion when compared to the intraindividual reference area (p < 0.0001). In VAC-treated wounds, a markedly increased perfusion was measured compared to the wounds closed primarily (p < 0.0001). Perfusion decreased during treatment, but in two VAC-treated wounds, an initial increase of the perfusion was observed. Both these wounds were grossly infected. PDUS allows the quantification of the differences in wound perfusion. This can be helpful in the detection of progressive local wound infections.

  20. PPG, APG, duplex: which noninvasive tests are most appropriate for the management of patients with chronic venous insufficiency?

    PubMed

    Marston, William A

    2002-03-01

    Numerous noninvasive tests have been described for assistance in the diagnosis and treatment of patients with chronic venous insufficiency (CVI). These tests include venous duplex ultrasound examination in the supine and standing positions, photoplethysmography (PPG), and air plethysmography (APG). The goal of these studies is to provide accurate information describing the anatomic or the hemodynamic characteristics of the patient with CVI, precluding the need for invasive studies. These tests will be reviewed including the typical information obtained, the usefulness of this information, and the relevance for clinical management of patients with CVI. Based on the clinical class, recommendations for a noninvasive testing protocol are outlined. Copyright 2002 by W.B. Saunders Company

  1. Venous Shunt Versus Venous Ligation for Vascular Damage Control: The Immunohistochemical Evidence.

    PubMed

    Góes Junior, Adenauer Marinho de Oliveira; Abib, Simone de Campos Vieira; Alves, Maria Teresa de Seixas; Ferreira, Paulo Sérgio Venerando da Silva; Andrade, Mariseth Carvalho de

    2017-05-01

    To evaluate the expression of immunohistochemical markers of tissue ischemia (iNOS, eNOS, and HSP70) in a vascular damage control experimental model to determine if a venous temporary vascular shunt insertion leads to a better limb perfusion when compared with the ligature of the injured vein. Experimental study in male Sus Scrofa weighting 40 Kg. Animals were distributed into 5 groups: group 1 animals were submitted to right external iliac artery (EIA) shunting and right external iliac vein (EIV) ligation; group 2 animals were submitted to right EIA shunting and right EIV shunting; group 3 animals were submitted to right EIV ligation; group 4 animals were submitted to right EIV shunting; group 5 animals were not submitted to vascular shunting or venous ligation. Transonic Systems flowmeters were used to measure vascular flow on right and left external iliac vessels, and i-STAT (Abbot) portable blood analyzer was used for EIVs blood biochemical analysis. An initial baseline register of invasive arterial pressure, iliac vessels flow, and venous blood analysis was performed. Arterial pressure and iliac vessels flow were taken immediately after right iliac vessels shunting or ligation. Then, hemorrhagic shock was induced by continuous 20 mL/min blood withdraw from the external right jugular vein whereas arterial blood pressure and iliac vessels flow registers were taken every 10 min, and blood samples from EIVs were obtained every 30 min until the vascular flow through right EIA (or through the shunt inserted into the right EIV for group 4 animals) became inexistent or until the animal's death. After the end of the experiments, bilateral hind limb's biopsies were obtained for immunohistochemical analysis. Using image editing and analysis software, the expression of iNOS, eNOS, and HSP70 (3 well-known ischemic associated immunohistochemical markers) was assessed. The mean expression of each marker in the right hind limb was compared between groups. For statistical

  2. A technological advance for 21st century obstetricians: the electronically-controlled vacuum extractor.

    PubMed

    Perone, Nicola

    2018-04-25

    To describe an innovative electronically-controlled vacuum extractor (VE) in detail and to illustrate its performance characteristics, as observed in a laboratory study. Thirty simulated, vacuum-assisted deliveries. (1) The ability to measure in real-time of the pull applied and to sound an alert, when the traction approaches the negative pressure under the cup, to prevent its detachment. (2) The recording and printing of a graphic representation of the pull applied (vacuum delivery graph). (3) The emission of a warning signal when the 15-min time limit of continuous cup application on the fetal scalp, is reached. No cup detachment occurred in any of the 15 vacuum-assisted deliveries, in which traction was kept below the adhesive force of the cup [44 lb (20 kg)], except in three cases, due to loss of negative pressure. In the remaining 15 tests, in which traction was greater than the adhesive force of the cup, "pull-offs" inevitably occurred. Furthermore, upon reaching the 15-min time limit of continuous cup application on the fetal cephalic model, a warning signal was emitted, as programmed. Conclusions We demonstrated that the electronically-controlled VE, with its distinctive pull-sensing handle, performs suitably for its intended purposes. The ability of the modernized device to decrease the incidence of cup detachment, secondary to the inadvertent application of excessive traction, may result in considerable safety, medico-legal and didactic advantages.

  3. Venous leg ulcers

    PubMed Central

    2011-01-01

    Introduction Leg ulcers usually occur secondary to venous reflux or obstruction, but 20% of people with leg ulcers have arterial disease, with or without venous disorders. Between 1.5 and 3.0/1000 people have active leg ulcers. Prevalence increases with age to about 20/1000 in people aged over 80 years. Methods and outcomes We conducted a systematic review and aimed to answer the following clinical questions: What are the effects of standard treatments, adjuvant treatments, and organisational interventions for venous leg ulcers? What are the effects of advice about self-help interventions in people receiving usual care for venous leg ulcers? What are the effects of interventions to prevent recurrence of venous leg ulcers? We searched: Medline, Embase, The Cochrane Library, and other important databases up to June 2011 (Clinical Evidence reviews are updated periodically; please check our website for the most up-to-date version of this review). We included harms alerts from relevant organisations such as the US Food and Drug Administration (FDA) and the UK Medicines and Healthcare products Regulatory Agency (MHRA). Results We found 101 systematic reviews, RCTs, or observational studies that met our inclusion criteria. We performed a GRADE evaluation of the quality of evidence for interventions. Conclusions In this systematic review we present information relating to the effectiveness and safety of the following interventions: compression bandages and stockings, cultured allogenic (single or bilayer) skin replacement, debriding agents, dressings (cellulose, collagen, film, foam, hyaluronic acid-derived, semi-occlusive alginate), hydrocolloid (occlusive) dressings in the presence of compression, intermittent pneumatic compression, intravenous prostaglandin E1, larval therapy, laser treatment (low-level), leg ulcer clinics, multilayer elastic system, multilayer elastomeric (or non-elastomeric) high-compression regimens or bandages, oral treatments (aspirin, flavonoids

  4. Routine Sub-hepatic Drainage versus No Drainage after Laparoscopic Cholecystectomy: Open, Randomized, Clinical Trial.

    PubMed

    Shamim, Muhammad

    2013-02-01

    Surgeons are still following the old habit of routine subhepatic drainage following laparoscopic cholecystectomy (LC). This study aims to compare the outcome of subhepatic drainage with no drainage after LC. This prospective study was conducted in two phases. Phase I was open, randomized controlled trial (RCT), conducted in Civil Hospital Karachi, from August 2004 to June 2005. Phase II was descriptive case series, conducted in author's practice hospitals of Karachi, from July 2005 to December 2009. In phase I, 170 patients with chronic calculous cholecystitis underwent LC. Patients were divided into two groups, subhepatic drainage (group A: 79 patients) or no drainage (group B: 76 patients). The rest 15 patients were excluded either due to conversion or elective subhepatic drainage. In phase II, 218 consecutive patients were enrolled, who underwent LC with no subhepatic drainage. Duration of operation, character, and amount of drain fluid (if placed), postoperative ultrasound for subhepatic collection, postoperative chest X-ray for the measurement of subdiaphragmatic air, postoperative pain, postoperative nausea/vomiting, duration of hospital stay, and preoperative or postoperative complications were noted and analyzed. Duration of operation and hospital stay was slightly longer in group A patients (P values 0.002 and 0.029, respectively); postoperative pain perception, nausea/vomiting, and postoperative complications were nearly same in both groups (P value 0.064, 0.078, and 0.003, respectively). Subhepatic fluid collection was more in group A (P = 0.002), whereas subdiaphragmatic air collection was more in group B (P = 0.003). Phase II results were nearly similar to group B patients in phase I. Routine subhepatic drainage after LC is not necessary in uncomplicated cases.

  5. Venous thromboembolism in assisted reproductive technologies: comparison between unsuccessful versus successful cycles in an Italian cohort.

    PubMed

    Villani, Michela; Favuzzi, Giovanni; Totaro, Pasquale; Chinni, Elena; Vecchione, Gennaro; Vergura, Patrizia; Fischetti, Lucia; Margaglione, Maurizio; Grandone, Elvira

    2018-02-01

    Pregnancies after assisted reproductive technologies (ART) have been associated with an increased risk of venous thromboembolism (VTE). On the contrary, the magnitude of this risk in unsuccessful ART cycles (not resulting in a clinical pregnancy) has not yet been clearly defined. In this study, we evaluated the incidence of VTE in unsuccessful cycles and compared it with that recorded in successful cycles in the same study population. From a cohort of 998 women consecutively referred by local Fertility Clinics to our Atherosclerosis and Thrombosis Unit (April 2002-July 2011), we identified and included women with at least one cycle of ovarian stimulation and a negative history for VTE. Overall, 661 women undergone 1518 unsuccessful and 318 successful cycles of ovarian stimulation, respectively, were analysed. VTE events occurred in 2/1518 (1.3‰) unsuccessful cycles compared with 3/318 (9.4‰) successful cycles, (Two-tailed Fisher exact test, p = 0.04, OR 0.14, 95% CI 0.02-1.02). Both cases observed in unsuccessful cycles were isolated pulmonary embolism occurred after OHSS; no antithrombotic prophylaxis had been prescribed. At logistic regression analysis, the occurrence of successful cycle and BMI were significantly and independently associated with the occurrence of VTE with an OR of 13.94 (95% CI 1.41-137.45) and 1.23 (95% CI 1.01-1.49), respectively. VTE incidence is significantly lower in unsuccessful cycles as compared to that of successful ones. However, although rare, thrombotic risk during ovarian stimulation cannot be excluded and, when it occurs, can be life-threatening. Therefore, particular attention should be paid to these women, independently of ART outcome.

  6. Comparison of closed-chest drainage with rib resection closed drainage for treatment of chronic tuberculous empyema

    PubMed Central

    Fang, Yong; Xiao, Heping; Hu, Haili

    2018-01-01

    Background This study aimed to compare the efficacy of closed-chest drainage with rib resection closed drainage of chronic tuberculous empyema. Methods This retrospective study reviewed 86 patients with tuberculous empyema in Shanghai Pulmonary Hospital from August 2010 to November 2015. Among these included patients, 22 patients received closed-chest drainage, and 64 patients received rib resection closed drainage. Results The results showed that after intercostal chest closed drain treatment, 2 (9.09%) patients were recovery, 13 (59.09%) patients had significantly curative effect, 6 (27.27%) patients had partly curative effect, and 1 (4.55%) patient had negative effect. After treatment of rib resection closed drainage, 9 (14.06%) patients were successfully recovery, 31 (48.44%) patients had significantly curative effect, 19 (29.69%) patients had partly curative effect, and 5 (7.81%) patients had negative effect. There was no significant difference in the curative effect (P>0.05), while the average catheterization time of rib resection closed drainage (130.05±13.12 days) was significant longer than that (126.14±36.84 days) in course of intercostal chest closed drain (P<0.05). Conclusions This study had demonstrated that closed-chest drainage was an effective procedure for treating empyema in young patients. It was less invasive than rib resection closed drainage and was associated with less severe pain. We advocated closed-chest drainage for the majority of young patients with empyema, except for those with other diseases. PMID:29600066

  7. Venous Small Bowel Infarction: Intraoperative Laser Doppler Flowmetry Discriminates Critical Blood Supply and Spares Bowel Length

    PubMed Central

    Käser, S. A.; Glauser, P. M.; Maurer, C. A.

    2012-01-01

    Introduction. In mesenteric infarction due to arterial occlusion, laser Doppler flowmetry and spectrometry are known reliable noninvasive methods for measuring microvascular blood flow and oxygen utilisation. Case Presentation. As an innovation we used these methods in a patient with acute extensive mesenteric infarction due to venous occlusion, occurring after radical right hemicolectomy. Aiming to avoid short bowel syndrome, we spared additional 110 cm of small bowel, instead of leaving only 80 centimetres of clinically viable small bowel in situ. The pathological examination showed only 5 mm of vital mucosa to be left distal to the dissection margin. No further interventions were necessary. Conclusion. Laser doppler flowmetry and spectrometry are potentially powerful methods to assist the surgeon's decision-making in critical venous mesenteric perfusion, thus having an important impact on clinical outcome. PMID:23093968

  8. Determination of transformation products of unsymmetrical dimethylhydrazine in water using vacuum-assisted headspace solid-phase microextraction.

    PubMed

    Orazbayeva, Dina; Kenessov, Bulat; Psillakis, Elefteria; Nassyrova, Dayana; Bektassov, Marat

    2018-06-22

    A new, sensitive and simple method based on vacuum-assisted headspace solid-phase microextraction (Vac-HSSPME) followed by gas chromatography-mass-spectrometry (GC-MS), is proposed for the quantification of rocket fuel unsymmetrical dimethylhydrazine (UDMH) transformation products in water samples. The target transformation products were: pyrazine, 1-methyl-1H-pyrazole, N-nitrosodimethylamine, N,N-dimethylformamide, 1-methyl-1Н-1,2,4-triazole, 1-methyl-imidazole and 1H-pyrazole. For these analytes and within shorter sampling times, Vac-HSSPME yielded detection limits (0.5-100 ng L -1 ) 3-10 times lower than those reported for regular HSSPME. Vac-HSSPME sampling for 30 min at 50 °C yielded the best combination of analyte responses and their standard deviations (<15%). 1-Formyl-2,2-dimethylhydrazine and formamide were discarded because of the poor precision and accuracy when using Vac-HSSPME. The recoveries for the rest of the analytes ranged between 80 and 119%. The modified Mininert valve and Thermogreen septum could be used for automated extraction as it ensured stable analyte signals even after long waiting times (>24 h). Finally, multiple Vac-HSSME proved to be an efficient tool for controlling the matrix effect and quantifying UDMH transformation products. Copyright © 2018 Elsevier B.V. All rights reserved.

  9. ZnO synthesis by high vacuum plasma-assisted chemical vapor deposition using dimethylzinc and atomic oxygen

    NASA Astrophysics Data System (ADS)

    Barnes, Teresa M.; Hand, Steve; Leaf, Jackie; Wolden, Colin A.

    2004-09-01

    Zinc oxide thin films were produced by high vacuum plasma-assisted chemical vapor deposition (HVP-CVD) from dimethylzinc (DMZn) and atomic oxygen. HVP-CVD is differentiated from conventional remote plasma-enhanced CVD in that the operating pressures of the inductively coupled plasma (ICP) source and the deposition chamber are decoupled. Both DMZn and atomic oxygen effuse into the deposition chamber under near collisionless conditions. The deposition rate was measured as a function of DMZn and atomic oxygen flux on glass and silicon substrates. Optical emission spectroscopy and quadrupole mass spectrometry (QMS) were used to provide real time analysis of the ICP source and the deposition chamber. The deposition rate was found to be first order in DMZn pressure and zero order in atomic oxygen density. All films demonstrated excellent transparency and were preferentially orientated along the c-axis. The deposition chemistry occurs exclusively through surface-mediated reactions, since the collisionless transport environment eliminates gas-phase chemistry. QMS analysis revealed that DMZn was almost completely consumed, and desorption of unreacted methyl radicals was greatly accelerated in the presence of atomic oxygen. Negligible zinc was detected in the gas phase, suggesting that Zn was efficiently consumed on the substrate and walls of the reactor.

  10. Vacuum-assisted stereotactic breast biopsy in the diagnosis and management of suspicious microcalcifications

    PubMed Central

    Esen, Gül; Tutar, Burçin; Uras, Cihan; Calay, Zerrin; İnce, Ümit; Tutar, Onur

    2016-01-01

    PURPOSE We aimed to present our biopsy method and retrospectively evaluate the results, upgrade rate, and follow-up findings of stereotactic vacuum-assisted breast biopsy (VABB) procedures performed in our clinic. METHODS Two hundred thirty-four patients with mammographically detected nonpalpable breast lesions underwent VABB using a 9 gauge biopsy probe and prone biopsy table. A total of 195 patients (median age 53 years, range 32–80 years) with 198 microcalcification-only lesions with a follow-up of at least one year were included in the study. The location of the lesion relative to the needle was determined from the postfire images, and unlike the conventional technique, tissue retrieval was predominantly performed from that location, followed by a complete 360° rotation, if needed. RESULTS The median core number was 8.5. Biopsy results revealed 135 benign, 24 atypical, and 39 malignant lesions. The total upgrade rate at surgery was 7.7% (6.1% for ductal carcinomas in situ and 10.5% for atypical lesions). Patients with benign lesions were followed up for a median period of 27.5 months, with no interval change. At the follow-up, scar formation was seen in 23 patients (17%); three of the scars were remarkable for resembling a malignancy. CONCLUSION Our biposy method is fast and practical, and it is easily tolerated by patients without compromising accuracy. Patients with a diagnosis of atypia still need to undergo a diagnostic surgical procedure and those with a malignancy need to undergo curative surgery, even if the lesion is totally excised at biopsy. VABB may leave a scar in the breast tissue, which may resemble a malignancy, albeit rarely. PMID:27306660

  11. Acute venous sinus thrombosis after chickenpox infection.

    PubMed

    Sardana, Vijay; Mittal, Lal Chand; Meena, S R; Sharma, Deepti; Khandelwal, Girish

    2014-08-01

    Chickenpox is one of the classic childhood diseases. Recently chicken pox has been reported in adults with more severe systemic and neurological complications. Cerebral venous thrombosis (CVT) is a life threatening disorder if not treated in time. We report a patient with post varicella CVT as a rare complication of primary Varicella zoster virus. Vasculitic arterial infarction is known while venous stroke has rarely been reported with Varicella-zoster virus infection. Here, we report an immunocompetent 30 yr old male who developed chickenpox after contact with his daughter two month back. He presented with acute neurological deficit, one week after onset of skin lesion. MR venography revealed non-visualisation of left transverse sinus and left sigmoid sinus suggestive of venous sinus thrombosis. Varicella infection is rarely associated with venous sinus thrombosis. Possibly hypercoagulable state produced by the infection or direct invasion of virus in venous endothelial wall with subsequent damage to endothelium leading to thrombosis could be the cause.

  12. Drainage networks after wildfire

    USGS Publications Warehouse

    Kinner, D.A.; Moody, J.A.

    2005-01-01

    Predicting runoff and erosion from watersheds burned by wildfires requires an understanding of the three-dimensional structure of both hillslope and channel drainage networks. We investigate the small-and large-scale structures of drainage networks using field studies and computer analysis of 30-m digital elevation model. Topologic variables were derived from a composite 30-m DEM, which included 14 order 6 watersheds within the Pikes Peak batholith. Both topologic and hydraulic variables were measured in the field in two smaller burned watersheds (3.7 and 7.0 hectares) located within one of the order 6 watersheds burned by the 1996 Buffalo Creek Fire in Central Colorado. Horton ratios of topologic variables (stream number, drainage area, stream length, and stream slope) for small-scale and large-scale watersheds are shown to scale geometrically with stream order (i.e., to be scale invariant). However, the ratios derived for the large-scale drainage networks could not be used to predict the rill and gully drainage network structure. Hydraulic variables (width, depth, cross-sectional area, and bed roughness) for small-scale drainage networks were found to be scale invariant across 3 to 4 stream orders. The relation between hydraulic radius and cross-sectional area is similar for rills and gullies, suggesting that their geometry can be treated similarly in hydraulic modeling. Additionally, the rills and gullies have relatively small width-to-depth ratios, implying sidewall friction may be important to the erosion and evolutionary process relative to main stem channels.

  13. Exploring Agricultural Drainage's Influence on Wetland and ...

    EPA Pesticide Factsheets

    Artificial agricultural drainage (i.e. surface ditches or subsurface tile) is an important agricultural management tool. Artificial drainage allows for timely fieldwork and adequate root aeration, resulting in greater crop yields for farmers. This practice is widespread throughout many regions of the United States and the network of artificial drainage is especially extensive in flat, poorly-drained regions like the glaciated Midwest. While beneficial for crop yields, agricultural drains often empty into streams within the natural drainage system. The increased network connectivity may lead to greater contributing area for watersheds, altered hydrology and increased conveyance of pollutants into natural water bodies. While studies and models at broader scales have implicated artificial drainage as an important driver of hydrological shifts and eutrophication, the actual spatial extent of artificial drainage is poorly known. Consequently, metrics of wetland and watershed connectivity within agricultural regions often fail to explicitly include artificial drainage. We use recent agricultural census data, soil drainage data, and land cover data to create estimates of potential agricultural drainage across the United States. We estimate that agricultural drainage in the US is greater than 31 million hectares and is concentrated in the upper Midwest Corn Belt, covering greater than 50% of available land for 114 counties. Estimated drainage values for numerous countie

  14. Infrared Laser Ablation with Vacuum Capture for Fingermark Sampling

    NASA Astrophysics Data System (ADS)

    Donnarumma, Fabrizio; Camp, Eden E.; Cao, Fan; Murray, Kermit K.

    2017-09-01

    Infrared laser ablation coupled to vacuum capture was employed to collect material from fingermarks deposited on surfaces of different porosity and roughness. Laser ablation at 3 μm was performed in reflection mode with subsequent capture of the ejecta with a filter connected to vacuum. Ablation and capture of standards from fingermarks was demonstrated on glass, plastic, aluminum, and cardboard surfaces. Using matrix assisted laser desorption ionization (MALDI), it was possible to detect caffeine after spiking with amounts as low as 1 ng. MALDI detection of condom lubricants and detection of antibacterial peptides from an antiseptic cream was demonstrated. Detection of explosives from fingermarks left on plastic surfaces as well as from direct deposition on the same surface using gas chromatography mass spectrometry (GC-MS) was shown. [Figure not available: see fulltext.

  15. Infrared Laser Ablation with Vacuum Capture for Fingermark Sampling.

    PubMed

    Donnarumma, Fabrizio; Camp, Eden E; Cao, Fan; Murray, Kermit K

    2017-09-01

    Infrared laser ablation coupled to vacuum capture was employed to collect material from fingermarks deposited on surfaces of different porosity and roughness. Laser ablation at 3 μm was performed in reflection mode with subsequent capture of the ejecta with a filter connected to vacuum. Ablation and capture of standards from fingermarks was demonstrated on glass, plastic, aluminum, and cardboard surfaces. Using matrix assisted laser desorption ionization (MALDI), it was possible to detect caffeine after spiking with amounts as low as 1 ng. MALDI detection of condom lubricants and detection of antibacterial peptides from an antiseptic cream was demonstrated. Detection of explosives from fingermarks left on plastic surfaces as well as from direct deposition on the same surface using gas chromatography mass spectrometry (GC-MS) was shown. Graphical Abstract ᅟ.

  16. Comparison of vacuum and non-vacuum urine tubes for urinary sediment analysis.

    PubMed

    Topcuoglu, Canan; Sezer, Sevilay; Kosem, Arzu; Ercan, Mujgan; Turhan, Turan

    2017-12-01

    Urine collection systems with aspiration system for vacuum tubes are becoming increasingly common for urinalysis, especially for microscopic examination of the urine. In this study, we aimed to examine whether vacuum aspiration of the urine sample has any adverse effect on sediment analysis by comparing results from vacuum and non-vacuum urine tubes. The study included totally 213 urine samples obtained from inpatients and outpatients in our hospital. Urine samples were collected to containers with aspiration system for vacuum tubes. Each sample was aliquoted to both vacuum and non-vacuum urine tubes. Urinary sediment analysis was performed using manual microscope. Results were evaluated using chi-square test. Comparison of the sediment analysis results from vacuum and non-vacuum urine tubes showed that results were highly concordant for erythrocyte, leukocyte and epithelial cells (gamma values 1, 0.997, and 0.994, respectively; p < .001). Results were also concordant for urinary casts, crystals and yeast (kappa values 0.815, 0.945 and 1, respectively; p < .001). The results show that in urinary sediment analysis, vacuum aspiration has no adverse effect on the cellular components except on casts.

  17. History of venous leg ulcers.

    PubMed

    Gianfaldoni, S; Wollina, U; Lotti, J; Gianfaldoni, R; Lotti, T; Fioranelli, M; Roccia, M G

    To retrieve the history of venous ulcers and of skin lesions in general, we must go back to the appearance of human beings on earth. It is interesting to note that cutaneous injuries evolved parallel to human society. An essential first step in the pathogenesis of ulcers was represented by the transition of the quadruped man to Homo Erectus. This condition was characterized by a greater gravitational pressure on the lower limbs, with consequences on the peripheral venous system. Furthermore, human evolution was characterized by an increased risk of traumatic injuries, secondary to his natural need to create fire and hunt (e.g. stones, iron, fire, animal fighting). Humans then began to fight one another until they came to real wars, with increased frequency of wounds and infectious complications. The situation degraded with the introduction of horse riding, introduced by the Scites, who first tamed animals in the 7th century BC. This condition exhibited iliac veins at compression phenomena, favouring the venous stasis. With time, man continued to evolve until the modern age, which is characterized by increased risk factors for venous wounds such as poor physical activity and dietary errors (1, 2).

  18. Daily nursing care on patients undergoing venous-venous extracorporeal membrane oxygenation: a challenging procedure!

    PubMed

    Redaelli, Sara; Zanella, Alberto; Milan, Manuela; Isgrò, Stefano; Lucchini, Alberto; Pesenti, Antonio; Patroniti, Nicolò

    2016-12-01

    Daily nursing in critical care patients may alter vital parameters, especially in the most critically ill patients. The aim of our study was to evaluate feasibility and safety of daily nursing on patients undergoing venous-venous extracorporeal membrane oxygenation (vv-ECMO) for severe respiratory failure. Daily nursing was performed following defined phases (sponge bath, elevation with scooping stretcher, change position of endotracheal tube, dressing replacement). We recorded physiological and ECMO parameters before and during daily nursing in 5 patients for several days (total: 25 daily nursing) and adverse events: desaturation, hypertension, reduction of mixed venous oxygen saturation, arterial oxygen saturation or ECMO blood flow and elevation in minute ventilation. Sedative drug dosage and additional bolus were recorded. Daily nursing was performed in 92 % of cases (23/25), with a minimum of two adverse events per daily nursing. Hypertension and tachycardia were mostly recorded at the beginning, while desaturation, reduction in mixed venous oxygen saturation and blood flow were recorded during elevation with scooping stretcher. Increase in minute ventilation was frequent in spontaneous breathing patients. Additional bolus of sedation was required before and/or during nursing. Daily nursing significantly alters physiologic parameters; thus, it should be performed only when physicians are readily available to treat adverse events.

  19. Spontaneously removed biliary stent drainage versus T-tube drainage after laparoscopic common bile duct exploration.

    PubMed

    Xu, Yakun; Dong, Chengyong; Ma, Kexin; Long, Fei; Jiang, Keqiu; Shao, Ping; Liang, Rui; Wang, Liming

    2016-09-01

    Several studies have shown the safety and feasibility of laparoscopic common bile duct exploration (LCBDE) as a minimally invasive treatment options for choledocholithiasis. Use of T-tube or biliary stent drainage tube placement after laparoscopic choledochotomy for common bile duct (CBD) stones is still under debate. This study tried to confirm the safety of spontaneously removable biliary stent in the distal CBD after LCBDE to allow choledochus primary closure. A total of 47 patients with choledocholithiasis underwent LCBDE with primary closure and internal drainage using a spontaneously removable biliary stent drainage tube (stent group, N = 22) or T-tube (T-tube group, N = 25). Operative parameters and outcomes are compared. Surgical time, intraoperative blood loss, length of hospital stay, drainage tube removal time, postoperative intestinal function recovery, and cost of treatment were all significantly lower in the stent group as compared to that in the T-tube group (P < 0.05 for all). Otherwise, Bile leakage between the two groups had no significant difference (P > 0.05). The biliary stent drainage tube was excreted spontaneously 4 to 14 days after surgery with the exception of one case, where endoscopic removal of biliary tube was required due to failure of its spontaneous discharge. LCBDE with primary closure and use of spontaneously removable biliary stent drainage showed advantage over the use of traditional T-tube drainage in patients with choledocholithiasis.

  20. Current Status of the Application of Intracranial Venous Sinus Stenting

    PubMed Central

    Xu, Kan; Yu, Tiecheng; Yuan, Yongjie; Yu, Jinlu

    2015-01-01

    The intracranial venous sinus is an important component of vascular disease. Many diseases involve the venous sinus and are accompanied by venous sinus stenosis (VSS), which leads to increased venous pressure and high intracranial pressure. Recent research has focused on stenting as a treatment for VSS related to these diseases. However, a systematic understanding of venous sinus stenting (VS-Stenting) is lacking. Herein, the literature on idiopathic intracranial hypertension (IIH), venous pulsatile tinnitus, sinus thrombosis, high draining venous pressure in dural arteriovenous fistula (AVF) and arteriovenous malformation (AVM), and tumor-caused VSS was reviewed and analyzed to summarize experiences with VS-Stenting as a treatment. The literature review showed that satisfactory therapeutic effects can be achieved through stent angioplasty. Thus, the present study suggests that selective stent release in the venous sinus can effectively treat these diseases and provide new possibilities for treating intracranial vascular disease. PMID:26516306

  1. [Venous thrombosis associated with central venous catheter use in patients with cancer].

    PubMed

    Iglesias Rey, Leticia; Fernández Pérez, Isaura; Barbagelata López, Cristina; Rivera Gallego, Alberto

    2015-01-01

    The use of central venous catheters for various applications (administration of chemotherapy, blood products and others) in patients with cancer is increasingly frequent. The association between thrombosis and catheter use has been fully established but aspects such as its causes, diagnosis, prophylaxis and treatment have not. We describe a case of thrombosis in a patient with cancer treated with chemotherapy who carried a central venous catheter. We also perform a review of the risk factors, the role of the prophylaxis and the treatment. Copyright © 2015 Elsevier España, S.L.U. All rights reserved.

  2. Effects of isokinetic calf muscle exercise program on muscle strength and venous function in patients with chronic venous insufficiency.

    PubMed

    Ercan, Sabriye; Çetin, Cem; Yavuz, Turhan; Demir, Hilmi M; Atalay, Yurdagül B

    2018-05-01

    Objective The aim of this study was to observe the change of the ankle joint range of motion, the muscle strength values measured with an isokinetic dynamometer, pain scores, quality of life scale, and venous return time in chronic venous insufficiency diagnosed patients by prospective follow-up after 12-week exercise program including isokinetic exercises. Methods The patient group of this study comprised 27 patients (23 female, 4 male) who were diagnosed with chronic venous insufficiency. An exercise program including isokinetic exercise for the calf muscle was given to patients three days per week for 12 weeks. At the end of 12 weeks, five of the patients left the study due to inadequate compliance with the exercise program. As a result, control data of 22 patients were included. Ankle joint range of active motion, isokinetic muscle strength, pain, quality of life, and photoplethysmography measurements were assessed before starting and after the exercise program. Results Evaluating changes of the starting and control data depending on time showed that all isokinetic muscle strength measurement parameters, range of motion, and overall quality of life values of patients improved. Venous return time values have also increased significantly ( p < 0.05). Conclusion In conclusion, increase in muscle strength has been provided with exercise therapy in patients with chronic venous insufficiency. It has been determined that the increase in muscle strength affected the venous pump and this ensured improvement in venous function and range of motion of the ankle. In addition, it has been detected that pain reduced and quality of life improved after the exercise program.

  3. Ultrasound-guided cable-free 13-gauge vacuum-assisted biopsy of non-mass breast lesions

    PubMed Central

    Seo, Jiwoon; Jang, Mijung; Yun, Bo La; Lee, Soo Hyun; Kim, Eun-Kyu; Kang, Eunyoung; Park, So Yeon; Moon, Woo Kyung; Choi, Hye Young; Kim, Bohyoung

    2017-01-01

    Purpose To compare the outcomes of ultrasound-guided core biopsy for non-mass breast lesions by the novel 13-gauge cable-free vacuum-assisted biopsy (VAB) and by the conventional 14-gauge semi-automated core needle biopsy (CCNB). Materials and methods Our institutional review board approved this prospective study, and all patients provided written informed consent. Among 1840 ultrasound-guided percutaneous biopsies performed from August 2013 to December 2014, 145 non-mass breast lesions with suspicious microcalcifications on mammography or corresponding magnetic resonance imaging finding were subjected to 13-gauge VAB or 14-gauge CCNB. We evaluated the technical success rates, average specimen numbers, and tissue sampling time. We also compared the results of percutaneous biopsy and final surgical pathologic diagnosis to analyze the rates of diagnostic upgrade or downgrade. Results Ultrasound-guided VAB successfully targeted and sampled all lesions, whereas CCNB failed to demonstrate calcification in four (10.3%) breast lesions with microcalcification on specimen mammography. The mean sampling time were 238.6 and 170.6 seconds for VAB and CCNB, respectively. No major complications were observed with either method. Ductal carcinoma in situ (DCIS) and atypical ductal hyperplasia (ADH) lesions were more frequently upgraded after CCNB (8/23 and 3/5, respectively) than after VAB (2/26 and 0/4, respectively P = 0.028). Conclusion Non-mass breast lesions were successfully and accurately biopsied using cable-free VAB. The underestimation rate of ultrasound-detected non-mass lesion was significantly lower with VAB than with CCNB. Trial registration CRiS KCT0002267. PMID:28628656

  4. Detection of deep venous thrombophlebitis by gallium 67 scintigraphy

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Miller, J.H.

    1981-07-01

    Deep venous thrombophlebitis may escape clinical detection. Three cases are reported in which whole-body gallium 67 scintigraphy was used to detect unsuspected deep venous thrombophlebitis related to indwelling catheters in three children who were being evaluated for fevers of unknown origin. Two of these children had septicemia from Candida organisms secondary to these venous lines. Gallium 67 scintigraphy may be useful in the detection of complications of indwelling venous catheters.

  5. Detection of deep venous thrombophlebitis by Gallium 67 scintigraphy

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Miller, J.H.

    1981-07-01

    Deep venous thrombophlebitis may escape clinical detection. Three cases are reported in which whole-body gallium 67 scintigraphy was used to detect unsuspected deep venous thrombophlebitis related to indwelling catheters in three children who were being evaluated for fevers of unknown origin. Two of these children had septicemia from Candida organisms secondary to these venous lines. Gallium 67 scintigraphy may be useful in the detection of complications of indwelling venous catheters.

  6. A randomized controlled trial of a mixed Kinesio taping-compression technique on venous symptoms, pain, peripheral venous flow, clinical severity and overall health status in postmenopausal women with chronic venous insufficiency.

    PubMed

    Aguilar-Ferrándiz, M Encarnación; Castro-Sánchez, Adelaida María; Matarán-Peñarrocha, Guillermo A; Guisado-Barrilao, Rafael; García-Ríos, M Carmen; Moreno-Lorenzo, Carmen

    2014-01-01

    To investigate the effect of a mixed Kinesio taping treatment in women with chronic venous insufficiency. A double-blinded randomized clinical trial. Clinical setting. One hundred and twenty postmenopausal women with mild-moderate chronic venous insufficiency were randomly assigned to an experimental group receiving standardized Kinesio taping treatment for gastrocnemius muscle enhancement and ankle functional correction, or to a placebo control group for simulated Kinesio taping. MAIN OUTCOMES VARIABLES: Venous symptoms, pain, photoplethysmographic measurements, bioelectrical impedance, temperature, severity and overall health were recorded at baseline and after four weeks of treatment. The 2 × 2 mixed model ANCOVA with repeated measurements showed statistically significant group * time interaction for heaviness (F = 22.99, p = 0.002), claudication (F = 8.57, p = 0.004), swelling (F = 22.58, p = 0.001), muscle cramps (F = 7.14, p = 0.008), venous refill time (right: F = 9.45, p = 0.023; left: F = 14.86, p = 0.001), venous pump function (right: F = 35.55, p = 0.004; left: F = 17.39 p = 0.001), extracellular water (right: F = 35.55, p = 0.004; left: F = 23.84, p = 0.001), severity (F = 18.47, p = 0.001), physical function (F = 9.15, p = 0.003) and body pain (F = 3.36, p = 0.043). Both groups reported significant reduction in pain. Mixed Kinesio taping-compression therapy improves symptoms, peripheral venous flow and severity and slightly increases overall health status in females with mild chronic venous insufficiency. Kinesio taping may have a placebo effect on pain.

  7. Demonstrations with a Vacuum: Old Demonstrations for New Vacuum Pumps.

    ERIC Educational Resources Information Center

    Greenslade, Thomas B., Jr.

    1989-01-01

    Explains mechanisms of 19th-century vacuum pumps. Describes demonstrations using the pump including guinea and feather tube, aurora tube, electric egg, Gassiots cascade, air mill, bell in vacuum, density and buoyancy of air, fountain in vacuum, mercury shower, palm and bladder glasses, Bacchus demonstration, pneumatic man-lifter, and Magdeburg…

  8. A study to evaluate patterns of superficial venous reflux in patients with primary chronic venous disease.

    PubMed

    Qureshi, Mahim I; Gohel, Manj; Wing, Louise; MacDonald, Andrew; Lim, Chung S; Ellis, Mary; Franklin, Ian J; Davies, Alun H

    2015-08-01

    This study assessed patterns of superficial reflux in patients with primary chronic venous disease. Retrospective review of all patient venous duplex ultrasonography reports at one institution between 2000 and 2009. Legs with secondary, deep or no superficial reflux were excluded. In total, 8654 limbs were scanned; 2559 legs from 2053 patients (mean age 52.3 years) were included for analysis. Great saphenous vein reflux predominated (68%), followed by combined great saphenous vein/small saphenous vein reflux (20%) and small saphenous vein reflux (7%). The majority of legs with competent saphenofemoral junction had below-knee great saphenous vein reflux (53%); incompetent saphenofemoral junction was associated with combined above and below-knee great saphenous vein reflux (72%). Isolated small saphenous vein reflux was associated with saphenopopliteal junction incompetence (61%), although the majority of all small saphenous vein reflux limbs had a competent saphenopopliteal junction (57%). Superficial venous reflux does not necessarily originate from a saphenous junction. Large prospective studies with interval duplex ultrasonography are required to unravel the natural history of primary chronic venous disease. © The Author(s) 2014.

  9. Note: A simple sample transfer alignment for ultra-high vacuum systems.

    PubMed

    Tamtögl, A; Carter, E A; Ward, D J; Avidor, N; Kole, P R; Jardine, A P; Allison, W

    2016-06-01

    The alignment of ultra-high-vacuum sample transfer systems can be problematic when there is no direct line of sight to assist the user. We present the design of a simple and cheap system which greatly simplifies the alignment of sample transfer devices. Our method is based on the adaptation of a commercial digital camera which provides live views from within the vacuum chamber. The images of the camera are further processed using an image recognition and processing code which determines any misalignments and reports them to the user. Installation has proven to be extremely useful in order to align the sample with respect to the transfer mechanism. Furthermore, the alignment software can be easily adapted for other systems.

  10. Comparison of natural drainage group and negative drainage groups after total thyroidectomy: prospective randomized controlled study.

    PubMed

    Woo, Seung Hoon; Kim, Jin Pyeong; Park, Jung Je; Shim, Hyun Seok; Lee, Sang Ha; Lee, Ho Joong; Won, Seong Jun; Son, Hee Young; Kim, Rock Bum; Son, Young-Ik

    2013-01-01

    The aim of this study was to compare a negative pressure drain with a natural drain in order to determine whether a negative pressure drainage tube causes an increase in the drainage volume. Sixty-two patients who underwent total thyroidectomy for papillary thyroid carcinoma (PTC) were enrolled in the study between March 2010 and August 2010 at Gyeongsang National University Hospital. The patients were prospectively and randomly assigned to two groups, a negative pressure drainage group (n=32) and natural drainage group (n=30). Every 3 hours, the volume of drainage was checked in the two groups until the tube was removed. The amount of drainage during the first 24 hours postoperatively was 41.68 ± 3.93 mL in the negative drain group and 25.3 ± 2.68 mL in the natural drain group (p<0.001). After 24 additional hours, the negative drain group was 35.19 ± 4.26 mL and natural drain groups 21.53 ± 2.90 mL (p<0.001). However, the drainage at postoperative day 3 was not statistically different between the two groups. In addition, the vocal cord palsy and temporary and permanent hypocalcemia were not different between the two groups. These results indicate that a negative pressure drain may increase the amount of drainage during the first 24-48 hours postoperatively. Therefore, it is not necessary to place a closed suction drain when only a total thyroidectomy is done.

  11. Preoperative biliary drainage for periampullary tumors causing obstructive jaundice; DRainage vs. (direct) OPeration (DROP-trial).

    PubMed

    van der Gaag, Niels A; de Castro, Steve M M; Rauws, Erik A J; Bruno, Marco J; van Eijck, Casper H J; Kuipers, Ernst J; Gerritsen, Josephus J G M; Rutten, Jan-Paul; Greve, Jan Willem; Hesselink, Erik J; Klinkenbijl, Jean H G; Rinkes, Inne H M Borel; Boerma, Djamila; Bonsing, Bert A; van Laarhoven, Cees J; Kubben, Frank J G M; van der Harst, Erwin; Sosef, Meindert N; Bosscha, Koop; de Hingh, Ignace H J T; Th de Wit, Laurens; van Delden, Otto M; Busch, Olivier R C; van Gulik, Thomas M; Bossuyt, Patrick M M; Gouma, Dirk J

    2007-03-12

    Surgery in patients with obstructive jaundice caused by a periampullary (pancreas, papilla, distal bile duct) tumor is associated with a higher risk of postoperative complications than in non-jaundiced patients. Preoperative biliary drainage was introduced in an attempt to improve the general condition and thus reduce postoperative morbidity and mortality. Early studies showed a reduction in morbidity. However, more recently the focus has shifted towards the negative effects of drainage, such as an increase of infectious complications. Whether biliary drainage should always be performed in jaundiced patients remains controversial. The randomized controlled multicenter DROP-trial (DRainage vs. Operation) was conceived to compare the outcome of a 'preoperative biliary drainage strategy' (standard strategy) with that of an 'early-surgery' strategy, with respect to the incidence of severe complications (primary-outcome measure), hospital stay, number of invasive diagnostic tests, costs, and quality of life. Patients with obstructive jaundice due to a periampullary tumor, eligible for exploration after staging with CT scan, and scheduled to undergo a "curative" resection, will be randomized to either "early surgical treatment" (within one week) or "preoperative biliary drainage" (for 4 weeks) and subsequent surgical treatment (standard treatment). Primary outcome measure is the percentage of severe complications up to 90 days after surgery. The sample size calculation is based on the equivalence design for the primary outcome measure. If equivalence is found, the comparison of the secondary outcomes will be essential in selecting the preferred strategy. Based on a 40% complication rate for early surgical treatment and 48% for preoperative drainage, equivalence is taken to be demonstrated if the percentage of severe complications with early surgical treatment is not more than 10% higher compared to standard treatment: preoperative biliary drainage. Accounting for a 10

  12. Three-dimensional venous anatomy of the dermis observed using stereography

    PubMed Central

    Imanishi, Nobuaki; Kishi, Kazuo; Chang, Hak; Nakajima, Hideo; Aiso, Sadakazu

    2008-01-01

    Veins of the dermis have been investigated mainly by histological methods in the fields of anatomy and histology, and a large number of schemata of the veins have been depicted in a variety of textbooks. However, the schemata are usually two-dimensional and it is therefore difficult to envisage the actual vasculature of the dermal veins. In this study, we performed a stereographic study of the skin of three fresh cadavers that had been injected with radio-opaque dye, which was dispersed throughout the entire body. A venous network consisting of venous polygons of various sizes existed just under the dermis or in the deep zone of the dermis, which is generally called the subdermal venous plexus. There were many small vessels towards the inside of each venous polygon, and most of them ascended, branching off stereoscopically. Those branches anastomosed with each other, and they formed the dermal and subpapillary venous plexuses. However, there was little vascular connection between dermal venous plexuses of different venous polygons. The characteristic structure of the dermal venous plexus has been considered to bring about venous congestion of the skin in various clinical situations. PMID:18422525

  13. Improved Vacuum Bazooka

    NASA Astrophysics Data System (ADS)

    Cockman, John

    2003-04-01

    This apparatus is a modification to the well-known "vacuum bazooka" (PIRA 2B30.70). My vacuum bazooka is easy to construct and demonstrate, requires no precise fittings, foil, or vacuum grease, and propels ping-pong balls at a tremendous velocity!

  14. A separate phase drag model and a surrogate approximation for simulation of the steam assisted gravity drainage (SAGD) process

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Padrino-Inciarte, Juan Carlos; Ma, Xia; VanderHeyden, W. Brian

    General ensemble phase averaged equations for multiphase flows have been specialized for the simulation of the steam assisted gravity drainage (SAGD) process. In the average momentum equation, fluid-solid and fluid-fluid viscous interactions are represented by separate force terms. This equation has a form similar to that of Darcy’s law for multiphase flow but augmented by the fluid-fluid viscous forces. Models for these fluid-fluid interactions are suggested and implemented into the numerical code CartaBlanca. Numerical results indicate that the model captures the main features of the multiphase flow in the SAGD process, but the detailed features, such as plumes are missed.more » We find that viscous coupling among the fluid phases is important. Advection time scales for the different fluids differ by several orders of magnitude because of vast viscosity differences. Numerically resolving all of these time scales is time consuming. To address this problem, we introduce a steam surrogate approximation to increase the steam advection time scale, while keeping the mass and energy fluxes well approximated. This approximation leads to about a 40-fold speed-up in execution speed of the numerical calculations at the cost of a few percent error in the relevant quantities.« less

  15. A separate phase drag model and a surrogate approximation for simulation of the steam assisted gravity drainage (SAGD) process

    DOE PAGES

    Padrino-Inciarte, Juan Carlos; Ma, Xia; VanderHeyden, W. Brian; ...

    2016-01-01

    General ensemble phase averaged equations for multiphase flows have been specialized for the simulation of the steam assisted gravity drainage (SAGD) process. In the average momentum equation, fluid-solid and fluid-fluid viscous interactions are represented by separate force terms. This equation has a form similar to that of Darcy’s law for multiphase flow but augmented by the fluid-fluid viscous forces. Models for these fluid-fluid interactions are suggested and implemented into the numerical code CartaBlanca. Numerical results indicate that the model captures the main features of the multiphase flow in the SAGD process, but the detailed features, such as plumes are missed.more » We find that viscous coupling among the fluid phases is important. Advection time scales for the different fluids differ by several orders of magnitude because of vast viscosity differences. Numerically resolving all of these time scales is time consuming. To address this problem, we introduce a steam surrogate approximation to increase the steam advection time scale, while keeping the mass and energy fluxes well approximated. This approximation leads to about a 40-fold speed-up in execution speed of the numerical calculations at the cost of a few percent error in the relevant quantities.« less

  16. Breast 3 T-MR imaging: indication for stereotactic vacuum-assisted breast biopsy.

    PubMed

    Yamamoto, Nobuko; Yoshizako, Takeshi; Yoshikawa, Kazuaki; Itakura, Masayuki; Maruyama, Riruke; Kitagaki, Hajime

    2014-01-01

    The purpose of this study was to assess indications for stereotactic vacuum-assisted breast biopsy (SVAB) evaluated by breast 3 T-magnetic resonance (3 T-MR) imaging in patients showing suspicious microcalcifications on mammography and negative ultrasound (US) findings. Fifty-five patients with 55 breast lesions showing suspicious microcalcifications on mammography and negative US findings underwent preoperative 3 T-MR examination including dynamic MR imaging. All patients underwent SVAB within 1 month of MR imaging. The pathological diagnosis of each breast lesion was made by examining tissues obtained by SVAB or radical/partial mastectomy. 3 T-MR imaging findings were evaluated by using the American College of Radiology Breast Imaging Reporting and Data System Atlas (BI-RADS-MRI) and then were correlated with the histopathological findings. When BI-RADS 4 and 5 MR imaging lesions were assumed to be malignant, the usefulness of 3 T-MR imaging was evaluated for diagnosis of impalpable breast lesions by SVAB among lesions with microcalcification detected by mammography and negative US findings. There were 21 malignant lesions, including 5 invasive ductal carcinomas, 16 lesions of ductal carcinoma in situ (DCIS). The sensitivity, specificity, positive predictive value, negative predictive value, and accuracy of 3 T-MR imaging for deciding the indications for SVAB was 90.5%, 97.1%, 95.0%, 94.3%, and 94.5%, respectively. The one-false negative case was a DCIS with small enhancing lesions (0.5 mm). The one false-positive case was ductal adenoma with a linear ductal pattern of enhancement. 3 T-MR imaging may be useful for deciding the indications for SVAB in patients who have breast lesions with microcalcification that are impalpable and are detected by mammography and negative US findings. However, our findings should be considered preliminary and further prospective investigation is required.

  17. Impact of stereotactic 11-g vacuum-assisted breast biopsy on cost of diagnosis in Austria.

    PubMed

    Gruber, R; Walter, E; Helbich, T H

    2011-01-01

    To determine the frequency with which stereotactic 11-g vacuum-assisted breast biopsy (11-g SVAB) obviates an open surgical biopsy (OSB), to compare the costs of these two biopsy methods, and to estimate the potential cost savings attributable to 11-g SVAB in the diagnosis of suspicious breast lesions in patients in Austria. We retrospectively reviewed 318 consecutive breast lesions of BI-RADS categories IV and V (microcalcifications n=166; masses n=152) on which 11-g SVAB and OSB were performed. Cost savings were calculated using nationally allowed flat rates and patient charges. Costs were measured from a hospital and a socioeconomic perspective. Common clinical scenarios and sensitivity analyses assessed the extent of achievable cost savings. 11-g SVAB obviated the need for an OSB in 93 (29%) of 318 women. Overall cost savings per 11-g SVAB over OSB were € 242 per case from a hospital perspective, and € 422 per case from a socioeconomic perspective. The use of 11-g SVAB decreased the cost of diagnosis by 7% from a hospital perspective, and by 10% from a socioeconomic perspective. In Austria, annual national savings of over 5 million Euro could be realized with the use of 11-g SVAB for the diagnosis of suspicious breast lesions. Although savings per case are modest, the national health care system realizes significant cost reduction as women benefit from a faster and less invasive approach to diagnosis. Copyright © 2009 Elsevier Ireland Ltd. All rights reserved.

  18. Percutaneous biliary drainage for high obstruction.

    PubMed

    Barth, K H

    1990-11-01

    PBD is the preferred route of palliative drainage for patients with high biliary obstruction. The frequency of bifurcational obstruction in this setting requires familiarity with drainages from both the right and the left transhepatic approach. The preferred right transhepatic approach is fluoroscopically guided; on the left, ultrasonography is the guidance of choice. Large caliber drainage catheters are required, and dilatation of the necessary transhepatic tracts is extremely painful unless adequate inhalation anesthesia or, preferably, epidural anesthesia, is provided. Long-term biliary drainage requires a choice between internal-external external drainage catheters and endoprostheses that is made by considering the patient's life expectancy and his or her adjustment to a stent extending to the outside. The feasibility of corrective procedures if an internal-external drainage catheter or an endoprosthesis becomes blocked needs to be considered before definitive placement. The interventional radiologist becomes intimately involved in the follow-up care of patients and frequently has to direct appropriate patient evaluation. Familiarity with antibiotic regimens is important.

  19. Computed tomography of partial anomalous pulmonary venous connection in adults.

    PubMed

    Haramati, Linda B; Moche, Ilana E; Rivera, Vivian T; Patel, Pavni V; Heyneman, Laura; McAdams, H Page; Issenberg, Henry J; White, Charles S

    2003-01-01

    To systematically describe the imaging features and clinical correlates of a partial anomalous pulmonary venous connection diagnosed on computed tomography (CT) in adults. Twenty-nine adults with a partial anomalous pulmonary venous connection on CT were retrospectively identified. There were 19 women and 10 men, with a mean age of 53 (range: 19-83) years. Four cases were identified by review of 1825 consecutive chest CT reports from July 2000-July 2001, and 25 cases were culled from chest radiology teaching files at 3 institutions. Inclusion criteria were availability of CT images and medical charts. Chest radiographs (25 of 29 cases) were reviewed for mediastinal contour abnormalities, heart size, and pulmonary vascular pattern. Chest CT scans were reviewed for location, size, and drainage site of the anomalous vein; presence or absence of a pulmonary vein in the normal location; cardiac size and configuration; and pulmonary vasculature. Charts were reviewed for evidence of pulmonary and cardiovascular disease, history of congenital heart disease, and results of other cardiac imaging. The prevalence of a partial anomalous pulmonary venous connection was 0.2% (4 of 1825 chest CT reports). Seventy-nine percent (23 of 29 patients) had an anomalous left upper lobe vein connecting to a persistent left vertical vein, only 5% (1 of 23 patients) of whom had a left upper lobe vein in the normal location. Seventeen percent (5 of 29 patients) had an anomalous right upper lobe vein draining into the superior vena cava, 60% (3 of 5 patients) of whom also had a right upper lobe pulmonary vein in the normal location. One patient (3%) had an anomalous right lower lobe vein draining into the suprahepatic inferior vena cava. Chest radiographic findings were abnormal left mediastinal contour in 64% (15 of 25 patients), abnormal right mediastinal contour in 8% (2 of 25 patients), and cardiomegaly in 24% (6 of 25 patients). Computed tomography findings were cardiomegaly in 48% (14 of

  20. Venous thromboembolism prophylaxis in gynecologic surgery: a systematic review.

    PubMed

    Rahn, David D; Mamik, Mamta M; Sanses, Tatiana V D; Matteson, Kristen A; Aschkenazi, Sarit O; Washington, Blair B; Steinberg, Adam C; Harvie, Heidi S; Lukban, James C; Uhlig, Katrin; Balk, Ethan M; Sung, Vivian W

    2011-11-01

    To comprehensively review and critically assess the available gynecologic surgery venous thromboembolism prophylaxis literature and provide clinical practice guidelines. MEDLINE and Cochrane databases from inception to July 2010. We included randomized controlled trials in gynecologic surgery populations. Interventions and comparators included graduated compression stockings, intermittent pneumatic compression, unfractionated heparin, and low molecular weight heparin; placebo and routine postoperative care were allowed as comparators. One thousand two hundred sixty-six articles were screened, and 14 randomized controlled trials (five benign gynecologic, nine gynecologic oncology) met eligibility criteria. In addition, nine prospective or retrospective studies with at least 150 women were identified and provided data on venous thromboembolism risk stratification, gynecologic laparoscopy, and urogynecologic populations. Two reviewers independently screened articles with discrepancies adjudicated by a third. Eligible randomized controlled trials were extracted for these characteristics: study, participant, surgery, intervention, comparator, and outcomes data, including venous thromboembolism incidence and bleeding complications. Studies were individually and collectively assessed for methodologic quality and strength of evidence. Overall incidence of clinical venous thromboembolism was 0-2% in the benign gynecologic population. With use of intermittent pneumatic compression for benign major procedures, venous thromboembolism incidence was less than 1%. No venous thromboembolisms were identified in prospective studies of benign laparoscopic procedures. Overall quality of evidence in the benign gynecologic literature was poor. Gynecologic-oncology randomized controlled trials reported venous thromboembolism incidence (including "silent" venous thromboembolisms) of 0-14.8% with prophylaxis and up to 34.6% without prophylaxis. Fair quality of evidence supports that

  1. Comparison of Natural Drainage Group and Negative Drainage Groups after Total Thyroidectomy: Prospective Randomized Controlled Study

    PubMed Central

    Woo, Seung Hoon; Kim, Jin Pyeong; Park, Jung Je; Shim, Hyun Seok; Lee, Sang Ha; Lee, Ho Joong; Won, Seong Jun; Son, Hee Young; Kim, Rock Bum

    2013-01-01

    Purpose The aim of this study was to compare a negative pressure drain with a natural drain in order to determine whether a negative pressure drainage tube causes an increase in the drainage volume. Materials and Methods Sixty-two patients who underwent total thyroidectomy for papillary thyroid carcinoma (PTC) were enrolled in the study between March 2010 and August 2010 at Gyeongsang National University Hospital. The patients were prospectively and randomly assigned to two groups, a negative pressure drainage group (n=32) and natural drainage group (n=30). Every 3 hours, the volume of drainage was checked in the two groups until the tube was removed. Results The amount of drainage during the first 24 hours postoperatively was 41.68±3.93 mL in the negative drain group and 25.3±2.68 mL in the natural drain group (p<0.001). After 24 additional hours, the negative drain group was 35.19±4.26 mL and natural drain groups 21.53±2.90 mL (p<0.001). However, the drainage at postoperative day 3 was not statistically different between the two groups. In addition, the vocal cord palsy and temporary and permanent hypocalcemia were not different between the two groups. Conclusion These results indicate that a negative pressure drain may increase the amount of drainage during the first 24-48 hours postoperatively. Therefore, it is not necessary to place a closed suction drain when only a total thyroidectomy is done. PMID:23225820

  2. Arterial Pulsations cannot Drive Intramural Periarterial Drainage: Significance for Aβ Drainage

    PubMed Central

    Diem, Alexandra K.; MacGregor Sharp, Matthew; Gatherer, Maureen; Bressloff, Neil W.; Carare, Roxana O.; Richardson, Giles

    2017-01-01

    Alzheimer's Disease (AD) is the most common form of dementia and to date there is no cure or efficient prophylaxis. The cognitive decline correlates with the accumulation of amyloid-β (Aβ) in the walls of capillaries and arteries. Our group has demonstrated that interstitial fluid and Aβ are eliminated from the brain along the basement membranes of capillaries and arteries, the intramural periarterial drainage (IPAD) pathway. With advancing age and arteriosclerosis, the stiffness of arterial walls, this pathway fails in its function and Aβ accumulates in the walls of arteries. In this study we tested the hypothesis that arterial pulsations drive IPAD and that a valve mechanism ensures the net drainage in a direction opposite to that of the blood flow. This hypothesis was tested using a mathematical model of the drainage mechanism. We demonstrate firstly that arterial pulsations are not strong enough to produce drainage velocities comparable to experimental observations. Secondly, we demonstrate that a valve mechanism such as directional permeability of the IPAD pathway is necessary to achieve a net reverse flow. The mathematical simulation results are confirmed by assessing the pattern of IPAD in mice using pulse modulators, showing no significant alteration of IPAD. Our results indicate that forces other than the cardiac pulsations are responsible for efficient IPAD. PMID:28883786

  3. 24 CFR 3280.610 - Drainage systems.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 24 Housing and Urban Development 5 2010-04-01 2010-04-01 false Drainage systems. 3280.610 Section... DEVELOPMENT MANUFACTURED HOME CONSTRUCTION AND SAFETY STANDARDS Plumbing Systems § 3280.610 Drainage systems. (a) General. (1) Each fixture directly connected to the drainage system shall be installed with a...

  4. Effect of venous and lymphatic congestion on lymph capillary pressure of the skin in healthy volunteers and patients with lymph edema.

    PubMed

    Gretener, S B; Läuchli, S; Leu, A J; Koppensteiner, R; Franzeck, U K

    2000-01-01

    The aim of the present study was to assess the influence of venous and lymphatic congestion on lymph capillary pressure (LCP) in the skin of the foot dorsum of healthy volunteers and of patients with lymph edema. LCP was measured at the foot dorsum of 12 patients with lymph edema and 18 healthy volunteers using the servo-nulling technique. Glass micropipettes (7-9 microm) were inserted under microscopic control into lymphatic microvessels visualized by fluorescence microlymphography before and during venous congestion. Venous and lymphatic congestion was attained by cuff compression (50 mm Hg) at the thigh level. Simultaneously, the capillary filtration rate was measured using strain gauge plethysmography. The mean LCP in patients with lymph edema increased significantly (p < 0.05) during congestion (15.7 +/- 8.8 mm Hg) compared to the control value (12.2 +/- 8.9 mm Hg). The corresponding values of LCP in healthy volunteers were 4.3 +/- 2.6 mm Hg during congestion and 2.6 +/- 2.8 mm Hg during control conditions (p < 0.01). The mean increase in LCP in patients with lymph edema was 3.4 +/- 4.1 mm Hg, and 1.7 +/- 2.0 mm Hg in healthy volunteers (NS). The maximum spread of the lymph capillary network in patients increased from 13.9 +/- 6.8 mm before congestion to 18.8 +/- 8.2 mm during thigh compression (p < 0.05). No increase could be observed in healthy subjects. In summary, venous and lymphatic congestion by cuff compression at the thigh level results in a significant increase in LCP in healthy volunteers as well as in patients with lymph edema. The increased spread of the contrast medium in the superficial microlymphatics in lymph edema patients indicates a compensatory mechanism for lymphatic drainage during congestion of the veins and lymph collectors of the leg. Copyright 2000 S. Karger AG, Basel

  5. Systemic Venous Inflow to the Liver Allograft to Overcome Diffuse Splanchnic Venous Thrombosis

    PubMed Central

    Darius, Tom; Goffette, Pierre; Lerut, Jan

    2015-01-01

    Diffuse splanchnic venous thrombosis (DSVT), formerly defined as contraindication for liver transplantation (LT), is a serious challenge to the liver transplant surgeon. Portal vein arterialisation, cavoportal hemitransposition and renoportal anastomosis, and finally combined liver and small bowel transplantation are all possible alternatives to deal with this condition. Five patients with preoperatively confirmed extensive splanchnic venous thrombosis were transplanted using cavoportal hemitransposition (4x) and renoportal anastomosis (1x). Median follow-up was 58 months (range: 0,5 to 130 months). Two patients with previous radiation-induced peritoneal injury died, respectively, 18 days and 2 months after transplantation. The three other patients had excellent long-term survival, despite the fact that two of them needed a surgical reintervention for severe gastrointestinal bleeding. Extensive splanchnic venous thrombosis is no longer an absolute contraindication to liver transplantation. Although cavoportal hemitransposition and renoportal anastomosis undoubtedly are life-saving procedures allowing for ensuring adequate allograft portal flow, careful follow-up of these patients remains necessary as both methods are unable to completely eliminate the complications of (segmental) portal hypertension. PMID:26539214

  6. Venous sinus occlusive disease: MR findings

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Yuh, W.T.C.; Simonson, T.M.; Tali, E.T.

    1994-02-01

    To study MR patterns of venous sinus occlusive disease and to relate them to the underlying pathophysiology by comparing the appearance and pathophysiologic features of venous sinus occlusive disease with those of arterial ischemic disease. The clinical data and MR examinations of 26 patients with venous sinus occlusive disease were retrospectively reviewed with special attention to mass effect, hemorrhage, and T2-weighted image abnormalities as well as to abnormal parenchymal, venous, or arterial enhancement after intravenous gadopentetate dimeglumine administration. Follow-up studies when available were evaluated for atrophy, infraction, chronic mass effect, and hemorrhage. Mass effect was present in 25 of 26more » patients. Eleven of the 26 had mass effect without abnormal signal on T2-weighted images. Fifteen patients had abnormal signal on T2-weighted images, but this was much less extensive than the degree of brain swelling in all cases. No patient showed abnormal parenchymal or arterial enhancement. Abnormal venous enhancement was seen in 10 of 13 patients who had contrast-enhanced studies. Intraparenchymal hemorrhage was seen in nine patients with high signal on T2-weighted images predominantly peripheral to the hematoma in eight. Three overall MR patterns were observed in acute sinus thrombosis: (1) mass effect without associated abnormal signal on T2-weighted images, (2) mass effect with associated abnormal signal on T2-weighted images and/or ventricular dilatation that may be reversible, and (3) intraparenchymal hematoma with surrounding edema. MR findings of venus sinus occlusive disease are different from those of arterial ischemia and may reflect different underlying pathophysiology. In venous sinus occlusive disease, the breakdown of the blood-brain barrier (vasogenic edema and abnormal parenchymal enhancement) does not always occur, and brain swelling can persist up to 2 years with or without abnormal signal on T2-weighted images. 34 refs., 5 figs.« less

  7. The Classical Vacuum.

    ERIC Educational Resources Information Center

    Boyer, Timothy H.

    1985-01-01

    The classical vacuum of physics is not empty, but contains a distinctive pattern of electromagnetic fields. Discovery of the vacuum, thermal spectrum, classical electron theory, zero-point spectrum, and effects of acceleration are discussed. Connection between thermal radiation and the classical vacuum reveals unexpected unity in the laws of…

  8. Intravascular thrombosis as a result of central venous access.

    PubMed

    Biernacka, Jadwiga; Nestorowicz, Andrzej; Wach, Małgorzata

    2002-01-01

    Central venous access represents one of the most basic therapeutic procedures in modern medicine. Unfortunately, numerous advantages that result from maintaining a central venous line are accompanied by some complications among which the venous thrombosis is the most significant clinically. The study was designed to assess frequency and natural history of this complication in the setting at a multi profile clinical hospital. Central venous cannulation was performed by a fully qualified anaesthesiologist in every case. There were 887 cannulations and only 5 patients with clinically significant venous thrombosis. The analysis of the collected data allowed us to state that the frequency of intravascular thrombosis is low, but this complication is often associated with extensive impairment of patency of the central veins. Full recanalization is not always achieved regardless of the treatment applied. Pulmonary embolism in the course of central venous thrombosis was diagnosed in one patient only and appeared as a multiple and fine X-ray infiltrates. It seems that in the presence of permanent or even life threatening complications of central venous thrombosis their risk should be minimized by frequent examination of the cannulation site and early initiation of antithrombotic treatment.

  9. Electroweak vacuum instability and renormalized Higgs field vacuum fluctuations in the inflationary universe

    NASA Astrophysics Data System (ADS)

    Kohri, Kazunori; Matsui, Hiroki

    2017-08-01

    In this work, we investigated the electroweak vacuum instability during or after inflation. In the inflationary Universe, i.e., de Sitter space, the vacuum field fluctuations < δ phi 2 > enlarge in proportion to the Hubble scale H2. Therefore, the large inflationary vacuum fluctuations of the Higgs field < δ phi 2 > are potentially catastrophic to trigger the vacuum transition to the negative-energy Planck-scale vacuum state and cause an immediate collapse of the Universe. However, the vacuum field fluctuations < δ phi 2 >, i.e., the vacuum expectation values have an ultraviolet divergence, and therefore a renormalization is necessary to estimate the physical effects of the vacuum transition. Thus, in this paper, we revisit the electroweak vacuum instability from the perspective of quantum field theory (QFT) in curved space-time, and discuss the dynamical behavior of the homogeneous Higgs field phi determined by the effective potential V eff( phi ) in curved space-time and the renormalized vacuum fluctuations < δ phi 2 >ren via adiabatic regularization and point-splitting regularization. We simply suppose that the Higgs field only couples the gravity via the non-minimal Higgs-gravity coupling ξ(μ). In this scenario, the electroweak vacuum stability is inevitably threatened by the dynamical behavior of the homogeneous Higgs field phi, or the formations of AdS domains or bubbles unless the Hubble scale is small enough H< ΛI .

  10. Assisted autogenic drainage in infants and young children hospitalized with uncomplicated pneumonia, a pilot study.

    PubMed

    Corten, Lieselotte; Jelsma, Jennifer; Human, Anri; Rahim, Sameer; Morrow, Brenda M

    2018-01-01

    Pneumonia is the most important respiratory problem in low-to-middle income countries. Airway clearance therapy continues to be used in children with pneumonia and secretion retention; however, there is lack of evidence to support or reject this treatment. This study aimed to investigate the feasibility of a randomized controlled trial (RCT) on the efficacy and safety of assisted autogenic drainage (AAD) compared to standard nursing care in children hospitalized with uncomplicated pneumonia. A single-blinded pilot RCT was conducted on 29 children (median age 3.5 months, IQR 1.5-9.4) hospitalized with uncomplicated pneumonia. The intervention group received standard nursing care with additional bi-daily AAD, for 10 to 30 min. The control group only received standard nursing care, unless otherwise deemed necessary by the physician or physiotherapist. The primary outcome measure was duration of hospitalization. The secondary outcome measures included days of fever and supplemental oxygen support; respiratory rate (RR) and heart rate adjusted for age; RR and oxygen saturation pre-, post-, and 1-hr post-treatment; oxygen saturation; adverse events; and mortality. No difference was found for duration of hospitalization (median 7.5 and 7.0 days for the control and intervention groups, respectively); however, Kaplan-Meier analysis revealed a strong tendency towards a shorter time to discharge in the intervention group (p = .06). No significant differences were found for the other outcome measures at time of discharge. No adverse events were reported. Within the intervention group, a significant reduction in RR adjusted for age was found. As no adverse events were reported, and AAD did not prolong hospitalization; AAD might be considered as safe and effective in young children with uncomplicated pneumonia. However, a larger multicentred RCT is warranted to determine the efficacy of AAD compared to standard nursing care. Copyright © 2017 John Wiley & Sons, Ltd.

  11. Imaging of head and neck venous malformations.

    PubMed

    Flis, Christine M; Connor, Stephen E

    2005-10-01

    Venous malformations (VMs) are non proliferative lesions that consist of dysplastic venous channels. The aim of imaging is to characterise the lesion and define its anatomic extent. We will describe the plain film, ultrasound (US) (including colour and duplex Doppler), computed tomography (CT), magnetic resonance imaging (MRI), conventional angiographic and direct phlebographic appearances of venous malformations. They will be illustrated at a number of head and neck locations, including orbit, oral cavity, superficial and deep facial space, supraglottic and intramuscular. An understanding of the classification of such vascular anomalies is required to define the correct therapeutic procedure to employ. Image-guided sclerotherapy alone or in combination with surgery is now the first line treatment option in many cases of head and neck venous malformations, so the radiologist is now an integral part of the multidisciplinary management team.

  12. Experimental use of high density polyethylene drainage pipe as a cross roadway drainage structure.

    DOT National Transportation Integrated Search

    2001-01-01

    Adequate drainage is one of the most important requirements in the reconstruction of a highway. Often it represents an appreciable expense of construction. In some applications installation costs may be reduced by the use of lighter weight drainage p...

  13. Cardiovascular Pressures with Venous Gas Embolism and Decompression

    NASA Technical Reports Server (NTRS)

    Butler, B. D.; Robinson, R.; Sutton, T.; Kemper, G. B.

    1995-01-01

    Venous gas embolism (VGE) is reported with decompression to a decreased ambient pressure. With severe decompression, or in cases where an intracardiac septal defect (patent foramen ovale) exists, the venous bubbles can become arterialized and cause neurological decompression illness. Incidence rates of patent foramen ovale in the general population range from 25-34% and yet aviators, astronauts, and deepsea divers who have decompression-induced venous bubbles do not demonstrate neurological symptoms at these high rates. This apparent disparity may be attributable to the normal pressure gradient across the atria of the heart that must be reversed for there to be flow potency. We evaluated the effects of: venous gas embolism (0.025, 0.05 and 0.15 ml/ kg min for 180 min.) hyperbaric decompression; and hypobaric decompression on the pressure gradient across the left and right atria in anesthetized dogs with intact atrial septa. Left ventricular end-diastolic pressure was used as a measure of left atrial pressure. In a total of 92 experimental evaluations in 22 dogs, there were no reported reversals in the mean pressure gradient across the atria; a total of 3 transient reversals occurred during the peak pressure gradient changes. The reasons that decompression-induced venous bubbles do not consistently cause serious symptoms of decompression illness may be that the amount of venous gas does not always cause sufficient pressure reversal across a patent foramen ovale to cause arterialization of the venous bubbles.

  14. Core content for training in venous and lymphatic medicine.

    PubMed

    Zimmet, Steven E; Min, Robert J; Comerota, Anthony J; Meissner, Mark H; Carman, Teresa L; Rathbun, Suman W; Jaff, Michael R; Wakefield, Thomas W; Feied, Craig F

    2014-10-01

    The major venous societies in the United States share a common mission to improve the standards of medical practitioners, the educational goals for teaching and training programs in venous disease, and the quality of patient care related to the treatment of venous disorders. With these important goals in mind, a task force made up of experts from the specialties of dermatology, interventional radiology, phlebology, vascular medicine, and vascular surgery was formed to develop a consensus document describing the Core Content for venous and lymphatic medicine and to develop a core educational content outline for training. This outline describes the areas of knowledge considered essential for practice in the field, which encompasses the study, diagnosis, and treatment of patients with acute and chronic venous and lymphatic disorders. The American Venous Forum and the American College of Phlebology have endorsed the Core Content. © The Author(s) 2014 Reprints and permissions: sagepub.co.uk/journalsPermissions.nav.

  15. Measurement of venous compliance (8-IML-1)

    NASA Technical Reports Server (NTRS)

    Thirsk, R. B.

    1992-01-01

    The prime objective of this International Microgravity Laboratory (IML-1) investigation is to measure the bulk compliance (distensibility) of the veins in the lower leg before, during, and after spaceflight. It is of particular interest whether venous compliance over the range of both positive and negative transmural pressures (various states of venous distention and collapse) changes throughout the duration of spaceflight. Information concerning the occurrence and character of compliance changes could have implications for the design of improved antigravity suits and further the understanding of inflight and postflight venous hemodynamics.

  16. Endoscopic Gallbladder Drainage for Acute Cholecystitis

    PubMed Central

    Widmer, Jessica; Alvarez, Paloma; Sharaiha, Reem Z.; Gossain, Sonia; Kedia, Prashant; Sarkaria, Savreet; Sethi, Amrita; Turner, Brian G.; Millman, Jennifer; Lieberman, Michael; Nandakumar, Govind; Umrania, Hiren; Gaidhane, Monica

    2015-01-01

    Background/Aims Surgery is the mainstay of treatment for cholecystitis. However, gallbladder stenting (GBS) has shown promise in debilitated or high-risk patients. Endoscopic transpapillary GBS and endoscopic ultrasound-guided GBS (EUS-GBS) have been proposed as safe and effective modalities for gallbladder drainage. Methods Data from patients with cholecystitis were prospectively collected from August 2004 to May 2013 from two United States academic university hospitals and analyzed retrospectively. The following treatment algorithm was adopted. Endoscopic retrograde cholangiopancreatography (ERCP) with sphincterotomy and cystic duct stenting was initially attempted. If deemed feasible by the endoscopist, EUS-GBS was then pursued. Results During the study period, 139 patients underwent endoscopic gallbladder drainage. Among these, drainage was performed in 94 and 45 cases for benign and malignant indications, respectively. Successful endoscopic gallbladder drainage was defined as decompression of the gallbladder without incidence of cholecystitis, and was achieved with ERCP and cystic duct stenting in 117 of 128 cases (91%). Successful endoscopic gallbladder drainage was also achieved with EUS-guided gallbladder drainage using transmural stent placement in 11 of 11 cases (100%). Complications occurred in 11 cases (8%). Conclusions Endoscopic gallbladder drainage techniques are safe and efficacious methods for gallbladder decompression in non-surgical patients with comorbidities. PMID:26473125

  17. Duplex imaging of residual venous obstruction to guide duration of therapy for lower extremity deep venous thrombosis.

    PubMed

    Stephenson, Elliot J P; Liem, Timothy K

    2015-07-01

    Clinical trials have shown that the presence of ultrasound-identified residual venous obstruction (RVO) on follow-up scanning may be associated with an elevated risk for recurrence, thus providing a potential tool to help determine the optimal duration of anticoagulant therapy. We performed a systematic review to evaluate the clinical utility of post-treatment duplex imaging in predicting venous thromboembolism (VTE) recurrence and in adjusting duration of anticoagulation. The Ovid MEDLINE Database, Cochrane Central Register of Controlled Trials, Cochrane Database of Systematic Reviews, and Database of Abstracts of Reviews of Effects were queried for the terms residual thrombus or obstruction, duration of therapy, deep vein thrombosis, deep venous thrombosis, DVT, venous thromboembolism, VTE, antithrombotic therapy, and anticoagulation, and 228 studies were selected for review. Six studies determined the rate of VTE recurrence on the basis of the presence or absence of RVO. Findings on venous ultrasound scans frequently remained abnormal in 38% to 80% of patients, despite at least 3 months of therapeutic anticoagulation. In evaluating for VTE recurrence, the definition of RVO varied widely in the literature. Some studies have shown an association between RVO and VTE recurrence, whereas other studies have not. Overall, the presence of RVO is a mild risk factor for recurrence (odds ratio, 1.3-2.0), but only when surveillance imaging is performed soon after the index deep venous thrombosis (3 months). RVO is a mild risk factor for VTE recurrence. The presence or absence of ultrasound-identified RVO has a limited role in guiding the duration of therapeutic anticoagulation. Further research is needed to evaluate its utility relative to other known risk factors for VTE recurrence. Copyright © 2015 Society for Vascular Surgery. Published by Elsevier Inc. All rights reserved.

  18. Multilayered Polysaccharide Nanofilms for Controlled Delivery of Pentoxifylline and Possible Treatment of Chronic Venous Ulceration.

    PubMed

    Stana, Jan; Stergar, Janja; Gradišnik, Lidija; Flis, Vojko; Kargl, Rupert; Fröhlich, Eleonore; Stana Kleinschek, Karin; Mohan, Tamilselvan; Maver, Uroš

    2017-09-11

    Local drug delivery systems made from nontoxic polysaccharide nanofilms have an enormous potential in wound care. A detailed understanding of the structural, surface, physicochemical, and cytotoxic properties of such systems is crucial to design clinically efficacious materials. Herein, we fabricated polysaccharide-based nanofilms onto either a 2D model (SiO 2 and Au sensors) or on nonwoven alginate 3D substrates using an alternating assembly of N,N,N-trimethylchitosan (TMC) and alginic acid (ALG) by a spin-assisted layer-by-layer (LbL) technique. These TMC/ALG multilayered nanofilms are used for a uniform encapsulation and controlled release of pentoxifylline (PTX), a potent anti-inflammatory drug for treatment of the chronic venous ulceration. We show a tailorable film growth and mass, morphology, as well as surface properties (charge, hydrophilicity, porosity) of the assembled nanofilms through control of the coating during the spin-assisted assembly. The uniform distribution of the encapsulated PTX in the TMC/ALG nanofilms is preserved even with when the amount of the incorporated PTX increases. The PTX release mechanism from the model and real systems is studied in detail and is very comparable for both systems. Finally, different cell-based assays illustrated the potential of the TMC/ALG multilayer system in wound care (e.g., treatment chronic venous ulceration) applications, including a decrease of TNF-α secretion, a common indicator of inflammation.

  19. Germanium detector vacuum encapsulation

    NASA Technical Reports Server (NTRS)

    Madden, N. W.; Malone, D. F.; Pehl, R. H.; Cork, C. P.; Luke, P. N.; Landis, D. A.; Pollard, M. J.

    1991-01-01

    This paper describes an encapsulation technology that should significantly improve the viability of germanium gamma-ray detectors for a number of important applications. A specialized vacuum chamber has been constructed in which the detector and the encapsulating module are processed in high vacuum. Very high vacuum conductance is achieved within the valveless encapsulating module. The detector module is then sealed without breaking the chamber vacuum. The details of the vacuum chamber, valveless module, processing, and sealing method are presented.

  20. Inventory of drainage wells and potential sources of contaminants to drainage-well inflow in Southwest Orlando, Orange County, Florida

    USGS Publications Warehouse

    Taylor, George Fred

    1993-01-01

    Potential sources of contaminants that could pose a threat to drainage-well inflow and to water in the Floridan aquifer system in southwest Orlando, Florida, were studied between October and December 1990. Drainage wells and public-supply wells were inventoried in a 14-square-mile area, and available data on land use and activities within each drainage well basin were tabulated. Three public-supply wells (tapping the Lower Floridan aquifer) and 38 drainage wells (open to the Upper Floridan aquifer) were located in 17 drainage basins within the study area. The primary sources of drainage-well inflow are lake overflow, street runoff, seepage from the surficial aquifer system, and process-wastewater disposal. Drainage-well inflow from a variety of ares, including resi- dential, commercial, undeveloped, paved, and industrial areas, are potential sources of con- taminants. The four general types of possible contaminants to drainage-well inflow are inorganic chemicals, organic compounds, turbidity, and microbiological contaminants. Potential contami- nant sources include plant nurseries, citrus groves, parking lots, plating companies, auto- motive repair shops, and most commonly, lake- overflow water. Drainage wells provide a pathway for contaminants to enter the Upper Floridan aquifer and there is a potential for contaminants to move downward from the Upper Floridan to the Lower Floridan aquifer.

  1. Venous compression syndrome of internal jugular veins prevalence in patients with multiple sclerosis and chronic cerebro-spinal venous insufficiency.

    PubMed

    Mandolesi, Sandro; Niglio, Tarcisio; Orsini, Augusto; De Sio, Simone; d'Alessandro, Alessandro; Mandolesi, Dimitri; Fedele, Francesco; d'Alessandro, Aldo

    2016-01-01

    Analysis of the incidence of Venous Compression Syndrome (VCS) with full block of the flow of the internal jugular veins (IJVs) in patients with Multiple Sclerosis and Chronic cerebro-spinal venous insufficiency. We included 769 patients with MS and CCSVI (299 males, 470 females) and 210 controls without ms and ccsvi (92 males, 118 females). each subject was investigated by echo-color-doppler (ecd). morphological and hemodynamic ecd data were recorded by a computerized mem-net maps of epidemiological national observatory on ccsvi and they were analyzed by mem-net clinical analysis programs. VCS of IJVs occurs in 240 subjects affected by CCSVI and MS (31% of total) and in 12 controls (6% of total). The differences between the two groups are statistical significant (X² = 36.64, p<0.0001). Up to day there are no longitudinal studies that allow us to identify the WC of jugular and/or vertebral veins as etiology of a chronic neurodegenerative disease, but we note that Venous Compression Syndrome of IJVs is strongly associated with MS and CCSVI. Chronic Cerebro-Spinal Venous Insufficiency, Multiple Sclerosis, Venous Compression Syndrome.

  2. Euclidean mirrors: enhanced vacuum decay from reflected instantons

    NASA Astrophysics Data System (ADS)

    Akal, Ibrahim; Moortgat-Pick, Gudrid

    2018-05-01

    We study the tunnelling of virtual matter–antimatter pairs from the quantum vacuum in the presence of a spatially uniform, time-dependent electric background composed of a strong, slow field superimposed with a weak, rapid field. After analytic continuation to Euclidean spacetime, we obtain from the instanton equations two critical points. While one of them is the closing point of the instanton path, the other serves as an Euclidean mirror which reflects and squeezes the instanton. It is this reflection and shrinking which is responsible for an enormous enhancement of the vacuum pair production rate. We discuss how important features of two different mechanisms can be analysed and understood via such a rotation in the complex plane. (a) Consistent with previous studies, we first discuss the standard assisted mechanism with a static strong field and certain weak fields with a distinct pole structure in order to show that the reflection takes place exactly at the poles. We also discuss the effect of possible sub-cycle structures. We extend this reflection picture then to weak fields which have no poles present and illustrate the effective reflections with explicit examples. An additional field strength dependence for the rate occurs in such cases. We analytically compute the characteristic threshold for the assisted mechanism given by the critical combined Keldysh parameter. We discuss significant differences between these two types of fields. For various backgrounds, we present the contributing instantons and perform analytical computations for the corresponding rates treating both fields nonperturbatively. (b) In addition, we also study the case with a nonstatic strong field which gives rise to the assisted dynamical mechanism. For different strong field profiles we investigate the impact on the critical combined Keldysh parameter. As an explicit example, we analytically compute the rate by employing the exact reflection points. The validity of the predictions

  3. Preliminary results after upper cervical chiropractic care in patients with chronic cerebro-spinal venous insufficiency and multiple sclerosis.

    PubMed

    Mandolesi, Sandro; Marceca, Giuseppe; Moser, Jon; Niglio, Tarcisio; d'Alessandro, Aldo; Ciccone, Matteo Marco; Zito, Annapaola; Mandolesi, Dimitri; d'Alessandro, Alessandro; Fedele, Francesco

    2015-01-01

    The aim of the study is to evaluate the clinical and X-ray results of the Upper Cervical Chiropractic care through the specific adjustments (corrections) of C1-C2 on patients with chronic venous cerebral-spinal insufficiency (CCSVI) and multiple sclerosis (MS). We studied a sample of 77 patients before and after the Upper Cervical Chiropractic care, and we analyzed: A) The change of the X-ray parameters; B) The clinical results using a new set of questions. The protocol of the C1- C2 upper Cervical Chiropractic treatment, specific for these patients, lasts four months. From a haemodynamic point of view we divided the patients in 3 types: Type 1 - purely vascular with intravenous alterations; Type 2 - "mechanical" with of external venous compressions; Type 3 - mixed. We found an improvement in all kinds of subluxations after the treatment with respect to the pre-treatment X-ray evaluation, with a significant statistical difference. The differences between the clinical symptoms before and after the specific treatment of C1-C2 are statistically significant with p<0.001 according to the CHI-Square test revised by Yates. The preliminary X-ray and clinical improvements of the Upper Cervical Chiropractic corrections on C1- C2 on these patients with CCSVI and MS encourage us to continue with our studies. We believe that the Upper Cervical correction on C1-C2 could be the main non-invasive treatment of the CCSVI mechanical type in patients with MS. Further studies are required to evaluate the correlation between the Upper Cervical Chiropractic correction on C1-C2 on the cerebral venous drainage and the cerebro-spinal fluid.

  4. Lifetime Risk of Venous Thromboembolism in Two Cohort Studies.

    PubMed

    Bell, Elizabeth J; Lutsey, Pamela L; Basu, Saonli; Cushman, Mary; Heckbert, Susan R; Lloyd-Jones, Donald M; Folsom, Aaron R

    2016-03-01

    Greater public awareness of venous thromboembolism may be an important next step for optimizing venous thromboembolism prevention and treatment. "Lifetime risk" is an easily interpretable way of presenting risk information. Therefore, we sought to calculate the lifetime risk of venous thromboembolism (deep vein thrombosis or pulmonary embolism) using data from 2 large, prospective cohort studies: the Cardiovascular Health Study (CHS) and the Atherosclerosis Risk in Communities (ARIC) study. We followed participants aged 45-64 years in ARIC (n = 14,185) and ≥65 in CHS (n = 5414) at baseline visits (1987-1989 in ARIC, 1989-1990 and 1992-1993 in CHS) for incident venous thromboembolism (n = 728 in ARIC through 2011 and n = 172 in CHS through 2001). We estimated lifetime risks and 95% confidence intervals of incident venous thromboembolism using a modified Kaplan-Meier method, accounting for the competing risk of death from other causes. At age 45 years, the remaining lifetime risk of venous thromboembolism in ARIC was 8.1% (95% confidence interval, 7.1-8.7). High-risk groups were African Americans (11.5% lifetime risk), those with obesity (10.9%), heterozygous for the factor V Leiden (17.1%), or with sickle cell trait or disease (18.2%). Lifetime risk estimates differed by cohort; these differences were explained by differences in time period of venous thromboembolism ascertainment. At least 1 in 12 middle-aged adults will develop venous thromboembolism in their remaining lifetime. This estimate of lifetime risk may be useful to promote awareness of venous thromboembolism and guide decisions at both clinical and policy levels. Copyright © 2016 Elsevier Inc. All rights reserved.

  5. 24 CFR 3280.610 - Drainage systems.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... diameter piping shall be required for water closets. (f) Wet-vented drainage system. Plumbing fixture traps... connected to the drainage system shall be installed with a water seal trap (§ 3280.606(a)). (2) The drainage... to which it is connected and shall be equipped with a water-tight cap or plug matching the drain...

  6. Randomised clinical trial of chest drainage systems.

    PubMed Central

    Graham, A N; Cosgrove, A P; Gibbons, J R; McGuigan, J A

    1992-01-01

    BACKGROUND: Problems in the management of thoracic trauma have stimulated the search for an alternative to underwater seals for drainage of the pleural cavity. A chest drainage bag incorporating a one way flutter valve has been compared with underwater seal drains in a randomised clinical trial. METHODS: During June-December 1989 119 patients undergoing elective thoracotomy were randomised to receive postoperative chest drainage by drainage bags (56 patients, 87 drains) or by underwater seal drains (63 patients, 98 drains). Daily drainage volumes, the requirement for pleural suction, mobility, and complications were recorded prospectively. RESULTS: There was no significant difference between the two groups in the mean volume drained, the requirements for pleural suction, or the occurrence of complications. Patients with drainage bags were fully mobile 23 hours (95% confidence interval 0-47 hours) earlier than the others. CONCLUSIONS: When used after elective thoracotomy drainage bags are safe and effective and permit earlier mobility than underwater seal drains. PMID:1496507

  7. Development of High Interruption Capability Vacuum Circuit Breaker -Technology of Vacuum Arc Control-

    NASA Astrophysics Data System (ADS)

    Niwa, Yoshimitsu; Kaneko, Eiji

    Vacuum circuit breakers (VCB) have been widely used for power distribution systems. Vacuum Interrupters, which are the current interruption unit, have been increased its interruption capability with the development of vacuum arc control technology by magnetic field. There are three major type electrodes: disk shaped electrodes, radial magnetic field electrodes, axial magnetic field (AMF) electrodes. In the disk shaped electrode, the vacuum arc between the electrodes is not controlled. In the AMF electrode, the vacuum arc is diffused and stabilized by an axial magnetic field, which is parallel to the arc current. In the last type of electrodes, the vacuum arc column is rotated by magnetic force generated by the current flowing in the electrodes. The interruption current and the voltage of one break VCB is increased to 100 kA, 144 kV respectively. This paper describes basic configurations and functions of VCB, vacuum arc control technology in vacuum interrupters, recent researches and applications of VCB.

  8. Prospective, randomised, controlled trial comparing suture needle drainage and argon laser drainage of subretinal fluid.

    PubMed Central

    Aylward, G W; Orr, G; Schwartz, S D; Leaver, P K

    1995-01-01

    AIMS--This study was designed to compare suture needle drainage (SND) with argon laser drainage (ALD) of subretinal fluid. METHODS--A prospective, randomised, controlled, clinical trial was carried out on 93 patients undergoing external drainage of subretinal fluid during scleral buckling surgery for rhegmatogenous retinal detachment. The incidence of successful drainage, incidence of subretinal haemorrhage, incidence of retinal incarceration, and incidence of retinal perforation were determined. RESULTS--The success rate was 97.9% in the ALD group and 84.8% in the SND group (difference-13.1%, 95% CI-26.4% to 2.0%). The incidence of clinically significant subretinal haemorrhage was 4.3% in the ALD group compared with 28.3% in the SND group (difference 24.0%, 95% CI 7.6% to 40.4%). The incidence of incarceration was comparable in each group. There were no cases of retinal perforation. CONCLUSIONS--The use of ALD was associated with a higher rate of successful SRF drainage, and a lower incidence of clinically significant subretinal haemorrhage than SND. ALD is preferred when an endolaser is available. PMID:7547781

  9. Electroweak vacuum instability and renormalized Higgs field vacuum fluctuations in the inflationary universe

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Kohri, Kazunori; Matsui, Hiroki, E-mail: kohri@post.kek.jp, E-mail: matshiro@post.kek.jp

    In this work, we investigated the electroweak vacuum instability during or after inflation. In the inflationary Universe, i.e., de Sitter space, the vacuum field fluctuations < δ φ {sup 2} > enlarge in proportion to the Hubble scale H {sup 2}. Therefore, the large inflationary vacuum fluctuations of the Higgs field < δ φ {sup 2} > are potentially catastrophic to trigger the vacuum transition to the negative-energy Planck-scale vacuum state and cause an immediate collapse of the Universe. However, the vacuum field fluctuations < δ φ {sup 2} >, i.e., the vacuum expectation values have an ultraviolet divergence, andmore » therefore a renormalization is necessary to estimate the physical effects of the vacuum transition. Thus, in this paper, we revisit the electroweak vacuum instability from the perspective of quantum field theory (QFT) in curved space-time, and discuss the dynamical behavior of the homogeneous Higgs field φ determined by the effective potential V {sub eff}( φ ) in curved space-time and the renormalized vacuum fluctuations < δ φ {sup 2} >{sub ren} via adiabatic regularization and point-splitting regularization. We simply suppose that the Higgs field only couples the gravity via the non-minimal Higgs-gravity coupling ξ(μ). In this scenario, the electroweak vacuum stability is inevitably threatened by the dynamical behavior of the homogeneous Higgs field φ, or the formations of AdS domains or bubbles unless the Hubble scale is small enough H < Λ {sub I} .« less

  10. Endoscopic ultrasound-guided biliary drainage

    PubMed Central

    Chavalitdhamrong, Disaya; Draganov, Peter V

    2012-01-01

    Endoscopic ultrasound (EUS)-guided biliary drainage has emerged as a minimally invasive alternative to percutaneous and surgical interventions for patients with biliary obstruction who had failed endoscopic retrograde cholangiopancreatography (ERCP). EUS-guided biliary drainage has become feasible due to the development of large channel curvilinear therapeutic echo-endoscopes and the use of real-time ultrasound and fluoroscopy imaging in addition to standard ERCP devices and techniques. EUS-guided biliary drainage is an attractive option because of its minimally invasive, single step procedure which provides internal biliary decompression. Multiple investigators have reported high success and low complication rates. Unfortunately, high quality prospective data are still lacking. We provide detailed review of the use of EUS for biliary drainage from the perspective of practicing endoscopists with specific focus on the technical aspects of the procedure. PMID:22363114

  11. Electronic versus traditional chest tube drainage following lobectomy: a randomized trial.

    PubMed

    Lijkendijk, Marike; Licht, Peter B; Neckelmann, Kirsten

    2015-12-01

    Electronic drainage systems have shown superiority compared with traditional (water seal) drainage systems following lung resections, but the number of studies is limited. As part of a medico-technical evaluation, before change of practice to electronic drainage systems for routine thoracic surgery, we conducted a randomized controlled trial (RCT) investigating chest tube duration and length of hospitalization. Patients undergoing lobectomy were included in a prospective open label RCT. A strict algorithm was designed for early chest tube removal, and this decision was delegated to staff nurses. Data were analysed by Cox proportional hazard regression model adjusting for lung function, gender, age, BMI, video-assisted thoracic surgery (VATS) or open surgery and presence of incomplete fissure or pleural adhesions. Time was distinguished as possible (optimal) and actual time for chest tube removal, as well as length of hospitalization. A total of 105 patients were randomized. We found no significant difference between the electronic group and traditional group in optimal chest tube duration (HR = 0.83; 95% CI: 0.55-1.25; P = 0.367), actual chest tube duration (HR = 0.84; 95% CI: 0.55-1.26; P = 0.397) or length of hospital stay (HR = 0.91; 95% CI: 0.59-1.39; P = 0.651). No chest tubes had to be reinserted. Presence of pleural adhesions or an incomplete fissure was a significant predictor of chest tube duration (HR = 1.72; 95% CI: 1.15-2.77; P = 0.014). Electronic drainage systems did not reduce chest tube duration or length of hospitalization significantly compared with traditional water seal drainage when a strict algorithm for chest tube removal was used. This algorithm allowed delegation of chest tube removal to staff nurses, and in some patients chest tubes could be removed safely on the day of surgery. © The Author 2015. Published by Oxford University Press on behalf of the European Association for Cardio-Thoracic Surgery. All rights reserved.

  12. All atypia diagnosed at stereotactic vacuum-assisted breast biopsy do not need surgical excision.

    PubMed

    de Mascarel, Isabelle; Brouste, Véronique; Asad-Syed, Maryam; Hurtevent, Gabrielle; Macgrogan, Gaëtan

    2011-09-01

    The necessity of excision is debatable when atypia are diagnosed at stereotactic vacuum-assisted breast biopsy (microbiopsy). Among the 287 surgical excisions performed at Institut Bergonié from 1999 to 2009, we selected a case-control study group of 151 excisions; 52 involving all the diagnosed cancers and 99 randomly selected among the 235 excisions without cancer, following atypical microbiopsy (24 flat epithelial atypia; 50 atypical ductal hyperplasia; 14 lobular neoplasia; 63 mixed lesions). Mammographical calcification (type, extension, complete removal) and histological criteria of epithelial atypia (type, number of foci, size/extension), topography and microcalcification extension at microbiopsy were compared according to the presence or absence of cancer at excision. Factors associated with cancer at excision were Breast Imaging Reporting and Data System (BI-RADS5) lesions, large and/or multiple foci of mammographical calcifications, histological type, number, size and extension of atypical foci. Flat epithelial atypia alone was never associated with cancer at excision. BI-RADS5, atypical ductal hyperplasia (alone or predominant) and >3 foci of atypia were identified as independent pejorative factors. There was never any cancer at excision when these pejorative factors were absent (n=31). Presence of one (n=59), two (n=23) or three (n=14) factors was associated with cancer in 24, 15 and 13 cases with an odds ratio=5.8 (95% CI: 3-11.2) for each additional factor. We recommend that mammographical data and histological characteristics be taken into account in the decision-making process after diagnosis of atypia on microbiopsy. With experienced senologists and strict histological criteria, some patients could be spared surgery resulting in significant patient, financial and time advantages.

  13. [Treatment of septic olecranon and patellar bursitis by excision and vacuum-assisted closure therapy].

    PubMed

    Walter, G; Kemmerer, M; Hoffmann, R

    2013-08-01

    Treatment of septic olecranon and patellar bursitis differs considerably and is currently under discussion. We therefore performed a retrospective study of our patients with septic bursitis in the past 5 years. Between March 2007 and February 2012 we treated 79 patients with septic olecranon (n = 43) and patellar (n = 36) bursitis surgically: 61-males, 18 females, age 51 (range: 11-91) years. Four patients had not been treated before, 25 had suffered recurrences after 1-10 previous procedures, and 9 patients had not improved after conservative therapy. 34 patients presented with traumatic rupture or fistula of their bursae. In all cases we performed a radical bursectomy and vacuum-assisted therapy for 4 to 5 days. In addition, patients received systemic antibiotics. We phoned all patients and were successful in 57 cases (72 %). We questioned these patients for range of movement, limitations at work, pain, sensibility disorder, satisfaction with the result and further surgical procedures. In all cases we took tissue specimens for cultures, in 48 preparations histological examination was performed. Microbiological and histological results are discussed in detail. 40 patients were free of complaints, 15 complained of mild pain, 54 of 57 had unlimited range of motion. Minor discomforts at desk work were reported by 5 of 43 patients, 12 out of 36 patient reported discomfort when performing on their knees. There was no recurrence in the period of investigation. We recommend our treatment concept for septic olecranon and patellar bursitis because patient satisfaction is high and recurrences are reliably avoided. The soft tissue is spared, so that plastic covering procedures are seldom necessary. Georg Thieme Verlag KG Stuttgart · New York.

  14. Effect of venous stenting on intracranial pressure in idiopathic intracranial hypertension.

    PubMed

    Matloob, Samir A; Toma, Ahmed K; Thompson, Simon D; Gan, Chee L; Robertson, Fergus; Thorne, Lewis; Watkins, Laurence D

    2017-08-01

    Idiopathic intracranial hypertension (IIH) is characterised by an increased intracranial pressure (ICP) in the absence of any central nervous system disease or structural abnormality and by normal CSF composition. Management becomes complicated once surgical intervention is required. Venous sinus stenosis has been suggested as a possible aetiology for IIH. Venous sinus stenting has emerged as a possible interventional option. Evidence for venous sinus stenting is based on elimination of the venous pressure gradient and clinical response. There have been no studies demonstrating the immediate effect of venous stenting on ICP. Patients with a potential or already known diagnosis of IIH were investigated according to departmental protocol. ICP monitoring was performed for 24 h. When high pressures were confirmed, CT venogram and catheter venography were performed to look for venous stenosis to demonstrate a pressure gradient. If positive, venous stenting would be performed and ICP monitoring would continue for a further 24 h after deployment of the venous stent. Ten patients underwent venous sinus stenting with concomitant ICP monitoring. Nine out of ten patients displayed an immediate reduction in their ICP that was maintained at 24 h. The average reduction in mean ICP and pulsatility was significant (p = 0.003). Six out of ten patients reported a symptomatic improvement within the first 2 weeks. Venous sinus stenting results in an immediate reduction in ICP. This physiological response to venous stenting has not previously been reported. Venous stenting could offer an alternative treatment option in correctly selected patients with IIH.

  15. Venous leakage treatment revisited: pelvic venoablation using aethoxysclerol under air block technique and Valsalva maneuver.

    PubMed

    Herwig, Ralf; Sansalone, Salvatore

    2015-03-31

    We evaluated the effectiveness of pelvic vein embolization with aethoxysclerol in aero-block technique for the treatment of impotence due to venous leakage in men using sildenafil for intercourse. The aim of the procedure was to reduce the use of sildenafil. A total of 96 patients with veno-occlusive dysfunction, severe enough for the need of PDE5 inhibitors for vaginal penetration, underwent pelvic venoablation with aethoxysclerol. The mean patient age was 53.5 years. Venous leaks were identified by Color Doppler Ultrasound after intracavernous alprostadil injection. Under local anesthesia a 20-gauge needle was inserted into the deep dorsal penile vein. The pelvic venogram was obtained through deep dorsal venography. Aethoxysclerol 3% as sclerosing agent was injected after air-block under Valsalva manoeuver. Success was defined as the ability to achieve vaginal insertion without the aid of any drugs, vasoactive injections, penile prosthesis, or vacuum device. Additionally, a pre- and post- therapy IIEF score and a digital overnight spontaneous erections protocol (OSEP) with the NEVA™-system was performed. At 3 month follow-up 77 out of 96 patients (80.21%) reported to have erections sufficient for vaginal insertion without the use of any drug or additional device. Four (4.17%) patients did not report any improvement. Follow up with color Doppler ultrasound revealed a new or persistent venous leakage in 8 (8.33%) of the patients. No serious complications occurred. Our new pelvic venoablation technique using aethoxysclerol in air-block technique was effective, minimally invasive, and cost-effective. All patients were able to perform sexual intercourse without the previously used dosage of PDE5 inhibitor. This new method may help in patients with contra-indications against PDE5 inhibitors, in patients who cannot afford the frequent usage of expensive oral medication or those who do not fully respond to PDE5-inhibitors.

  16. Venous Return and Clinical Hemodynamics: How the Body Works during Acute Hemorrhage

    ERIC Educational Resources Information Center

    Shen, Tao; Baker, Keith

    2015-01-01

    Venous return is a major determinant of cardiac output. Adjustments within the venous system are critical for maintaining venous pressure during loss in circulating volume. This article reviews two factors that are thought to enable the venous system to compensate during acute hemorrhage: 1) changes in venous elastance and 2) mobilization of…

  17. Concurrent Angioplasty Balloon Placement for Stent Delivery through Jugular Venous Bulb for Treating Cerebral Venous Sinus Stenosis. Technical Report.

    PubMed

    Qureshi, Adnan I; Khan, Asif A; Capistrant, Rachel; Qureshi, Mushtaq H; Xie, Kevin; Suri, M Fareed K

    2016-10-01

    To report upon technique of concurrent placement of angioplasty balloon at the internal jugular vein and sigmoid venous sinus junction to facilitate stent delivery in two patients in whom stent delivery past the jugular bulb was not possible. A 21-year-old woman and a 41-year-old woman with worsening headaches, visual obscuration or diplopia were treated for pseudotumor cerebri associated with transverse venous stenosis. Both patients had undergone primary angioplasty, which resulted in improvement in clinical symptoms followed by the recurrence of symptoms with restenosis at the site of angioplasty. After multiple attempts at stent delivery through jugular venous bulb were unsuccessful, a second guide catheter was placed in the ipsilateral internal jugular vein through contralateral femoral venous approach. A 6 mm × 20 mm (left) or 5 × 15 mm (right) angioplasty balloon was placed across the internal jugular vein and sigmoid sinus junction and partially inflated until the inflation and relative straightening of the junction was observed. In both patients, the internal jugular vein and sigmoid sinus junction was successfully traversed by the stent delivery system in a parallel alignment to inflated balloon. Balloon mounted stent was deployed at the site of restenosis with near complete resolution of lumen narrowing delivery and improvement in clinical symptoms. We report a technique for realignment and diameter change with concurrent placement and partial inflation of angioplasty balloon at the jugular venous bulb to facilitate stent delivery into the sigmoid and transverse venous sinuses in circumstances where multiple attempts at stent delivery are unsuccessful.

  18. Advances in drainage: Selected works from the Tenth International Drainage Symposium

    USGS Publications Warehouse

    Strock, Jeffrey S.; Hay, Christopher; Helmers, Matthew; Nelson, Kelly A.; Sands, Gary R.; Skaggs, R. Wayne; Douglas-Mankin, Kyle R.

    2018-01-01

    This article introduces a special collection of fourteen articles accepted from among the 140 technical presentations, posters, and meeting papers presented at the 10th International ASABE Drainage Symposium. The symposium continued in the tradition of previous symposia that began in 1965 as a forum for presenting and assessing the progress of drainage research and implementation throughout the world. The articles in this collection address a wide range of topics grouped into five broad categories: (1) crop response, (2) design and management, (3) hydrology and scale, (4) modeling, and (5) water quality. The collection provides valuable information for scientists, engineers, planners, and others working on crop production, water quality, and water quantity issues affected by agricultural drainage. The collection also provides perspectives on the challenges of increasing agricultural production in a changing climate, with ever-greater attention to water quality and quantity concerns that will require integrated technical, economic, and social solutions.

  19. Low-dose aspirin for preventing recurrent venous thromboembolism.

    PubMed

    Brighton, Timothy A; Eikelboom, John W; Mann, Kristy; Mister, Rebecca; Gallus, Alexander; Ockelford, Paul; Gibbs, Harry; Hague, Wendy; Xavier, Denis; Diaz, Rafael; Kirby, Adrienne; Simes, John

    2012-11-22

    Patients who have had a first episode of unprovoked venous thromboembolism have a high risk of recurrence after anticoagulants are discontinued. Aspirin may be effective in preventing a recurrence of venous thromboembolism. We randomly assigned 822 patients who had completed initial anticoagulant therapy after a first episode of unprovoked venous thromboembolism to receive aspirin, at a dose of 100 mg daily, or placebo for up to 4 years. The primary outcome was a recurrence of venous thromboembolism. During a median follow-up period of 37.2 months, venous thromboembolism recurred in 73 of 411 patients assigned to placebo and in 57 of 411 assigned to aspirin (a rate of 6.5% per year vs. 4.8% per year; hazard ratio with aspirin, 0.74; 95% confidence interval [CI], 0.52 to 1.05; P=0.09). Aspirin reduced the rate of the two prespecified secondary composite outcomes: the rate of venous thromboembolism, myocardial infarction, stroke, or cardiovascular death was reduced by 34% (a rate of 8.0% per year with placebo vs. 5.2% per year with aspirin; hazard ratio with aspirin, 0.66; 95% CI, 0.48 to 0.92; P=0.01), and the rate of venous thromboembolism, myocardial infarction, stroke, major bleeding, or death from any cause was reduced by 33% (hazard ratio, 0.67; 95% CI, 0.49 to 0.91; P=0.01). There was no significant between-group difference in the rates of major or clinically relevant nonmajor bleeding episodes (rate of 0.6% per year with placebo vs. 1.1% per year with aspirin, P=0.22) or serious adverse events. In this study, aspirin, as compared with placebo, did not significantly reduce the rate of recurrence of venous thromboembolism but resulted in a significant reduction in the rate of major vascular events, with improved net clinical benefit. These results substantiate earlier evidence of a therapeutic benefit of aspirin when it is given to patients after initial anticoagulant therapy for a first episode of unprovoked venous thromboembolism. (Funded by National Health

  20. [Ascites drainage at home].

    PubMed

    Lutjeboer, Jacob; van Erkel, Arian R; van der Hoeven, J J M Koos; van der Meer, Rutger W

    2015-01-01

    Ascites can lead to many symptoms, and often occurs in patients with an end-stage malignancy such as ovarian, pancreatic, colonic, or gastric cancer. Intermittent ascites drainage is applied in these patients as a palliative measure. As frequent drainage is necessary, a subcutaneously tunnelled permanent ascites catheter is a good alternative for intermittent drainage. The patient can open - and then re-close - the catheter when abdominal pressure increases. We inserted 35 subcutaneously permanent ascites catheters in the course of the past 3.5 years in the Leiden University Medical Centre. The success rate was 100% and the complication risk was 2.9%. A subcutaneously tunnelled ascites catheter is an effective and safe palliative treatment for patients with end-stage malignant disease and suffering from ascites.

  1. To shunt or not to shunt? An experimental study comparing temporary vascular shunts and venous ligation as damage control techniques for vascular trauma.

    PubMed

    Marinho de Oliveira Góes Junior, Adenauer; de Campos Vieira Abib, Simone; de Seixas Alves, Maria Teresa; Venerando da Silva Ferreira, Paulo Sérgio; Carvalho de Andrade, Mariseth

    2014-04-01

    Eq/L on the left EIV (P < 0.05). In the developed experimental model, venous shunting, when compared with venous ligation, offered less resistance to vascular flow through the arterial shunt and allowed a more efficient limb venous drainage than simple vein ligature. Copyright © 2014 Elsevier Inc. All rights reserved.

  2. [Emphysematous gastritis with concomitant portal venous air].

    PubMed

    Jeong, Min Yeong; Kim, Jin Il; Kim, Jae Young; Kim, Hyun Ho; Jo, Ik Hyun; Seo, Jae Hyun; Kim, Il Kyu; Cheung, Dae Young

    2015-02-01

    Emphysematous gastritis is a rare form of gastritis caused by infection of the stomach wall by gas forming bacteria. It is a very rare condition that carries a high mortality rate. Portal venous gas shadow represents elevation of intestinal luminal pressure which manifests as emphysematous gastritis or gastric emphysema. Literature reviews show that the mortality rate is especially high when portal venous gas shadow is present on CT scan. Until recently, the treatment of emphysematous gastritis has been immediate surgical intervention. However, there is a recent trend of avoiding surgery because of the frequent occurrence of post-operative complications such as anastomosis leakage. In addition, aggressive surgical treatment has failed to show significant improvement in prognosis. Recently, the authors experienced a case of emphysematous gastritis accompanied by portal venous gas which was treated successfully by conservative treatment without immediate surgical intervention. Herein, we present a case of emphysematous gastritis with concomitant portal venous air along with literature review.

  3. [Venous thromboembolic disease: presentation of a case].

    PubMed

    Mirpuri-Mirpuri, P G; Álvarez-Cordovés, M M; Pérez-Monje, A

    2013-01-01

    Venous thromboembolic disease in its clinical spectrum includes both deep vein thrombosis and pulmonary thromboembolism, which is usually a complication of deep vein thrombosis. It is a relatively common disease with significant morbidity and requires an accurate diagnosis. They are numerous risk factors for venous thromboembolism, and there is evidence that the risk of thromboembolic disease increases proportionally to the number of predisposing risk factors present. The primary care physician should know the risk factors and suspect the presence of venous thromboembolic disease when there is a compatible clnical picture. The treatment for this pathology is anticoagulation. We report a patient with cardiovascular risk factors who was seen with pain in the right leg and shortness of breath and referred to the hospital with suspected venous thromboembolism, atrial fibrillation and pleural effusion. Copyright © 2012 Sociedad Española de Médicos de Atención Primaria (SEMERGEN). Publicado por Elsevier España. All rights reserved.

  4. Pathophysiology of spontaneous venous gas embolism

    NASA Technical Reports Server (NTRS)

    Lambertsen, C. J.; Albertine, K. H.; Pisarello, J. B.; Flores, N. D.

    1991-01-01

    The use of controllable degrees and durations of continuous isobaric counterdiffusion venous gas embolism to investigate effects of venous gas embolism upon blood, cardiovascular, and respiratory gas exchange function, as well as pathological effects upon the lung and its microcirculation is discussed. Use of N2O/He counterdiffusion permitted performance of the pathophysiologic and pulmonary microstructural effects at one ATA without hyperbaric or hypobaric exposures.

  5. Pre-operative biliary drainage for obstructive jaundice

    PubMed Central

    Fang, Yuan; Gurusamy, Kurinchi Selvan; Wang, Qin; Davidson, Brian R; Lin, He; Xie, Xiaodong; Wang, Chaohua

    2014-01-01

    Background Patients with obstructive jaundice have various pathophysiological changes that affect the liver, kidney, heart, and the immune system. There is considerable controversy as to whether temporary relief of biliary obstruction prior to major definitive surgery (pre-operative biliary drainage) is of any benefit to the patient. Objectives To assess the benefits and harms of pre-operative biliary drainage versus no pre-operative biliary drainage (direct surgery) in patients with obstructive jaundice (irrespective of a benign or malignant cause). Search methods We searched the Cochrane Hepato-Biliary Group Controlled Trials Register, Cochrane Central Register of Controlled Clinical Trials (CENTRAL) in The Cochrane Library, MEDLINE, EMBASE, and Science Citation Index Expanded until February 2012. Selection criteria We included all randomised clinical trials comparing biliary drainage followed by surgery versus direct surgery, performed for obstructive jaundice, irrespective of the sample size, language, and publication status. Data collection and analysis Two authors independently assessed trials for inclusion and extracted data. We calculated the risk ratio (RR), rate ratio (RaR), or mean difference (MD) with 95% confidence intervals (CI) based on the available patient analyses. We assessed the risk of bias (systematic overestimation of benefit or systematic underestimation of harm) with components of the Cochrane risk of bias tool. We assessed the risk of play of chance (random errors) with trial sequential analysis. Main results We included six trials with 520 patients comparing pre-operative biliary drainage (265 patients) versus no pre-operative biliary drainage (255 patients). Four trials used percutaneous transhepatic biliary drainage and two trials used endoscopic sphincterotomy and stenting as the method of pre-operative biliary drainage. The risk of bias was high in all trials. The proportion of patients with malignant obstruction varied between 60

  6. Preoperative endoscopic versus percutaneous transhepatic biliary drainage in potentially resectable perihilar cholangiocarcinoma (DRAINAGE trial): design and rationale of a randomized controlled trial.

    PubMed

    Wiggers, Jimme K; Coelen, Robert J S; Rauws, Erik A J; van Delden, Otto M; van Eijck, Casper H J; de Jonge, Jeroen; Porte, Robert J; Buis, Carlijn I; Dejong, Cornelis H C; Molenaar, I Quintus; Besselink, Marc G H; Busch, Olivier R C; Dijkgraaf, Marcel G W; van Gulik, Thomas M

    2015-02-14

    Liver surgery in perihilar cholangiocarcinoma (PHC) is associated with high postoperative morbidity because the tumor typically causes biliary obstruction. Preoperative biliary drainage is used to create a safer environment prior to liver surgery, but biliary drainage may be harmful when severe drainage-related complications deteriorate the patients' condition or increase the risk of postoperative morbidity. Biliary drainage can cause cholangitis/cholecystitis, pancreatitis, hemorrhage, portal vein thrombosis, bowel wall perforation, or dehydration. Two methods of preoperative biliary drainage are mostly applied: endoscopic biliary drainage, which is currently used in most regional centers before referring patients for surgical treatment, and percutaneous transhepatic biliary drainage. Both methods are associated with severe drainage-related complications, but two small retrospective series found a lower incidence in the number of preoperative complications after percutaneous drainage compared to endoscopic drainage (18-25% versus 38-60%, respectively). The present study randomizes patients with potentially resectable PHC and biliary obstruction between preoperative endoscopic or percutaneous transhepatic biliary drainage. The study is a multi-center trial with an "all-comers" design, randomizing patients between endoscopic or percutaneous transhepatic biliary drainage. All patients selected to potentially undergo a major liver resection for presumed PHC are eligible for inclusion in the study provided that the biliary system in the future liver remnant is obstructed (even if they underwent previous inadequate endoscopic drainage). Primary outcome measure is the total number of severe preoperative complications between randomization and exploratory laparotomy. The study is designed to detect superiority of percutaneous drainage: a provisional sample size of 106 patients is required to detect a relative decrease of 50% in the number of severe preoperative

  7. Pentoxifylline for treating venous leg ulcers.

    PubMed

    Jull, Andrew B; Arroll, Bruce; Parag, Varsha; Waters, Jill

    2012-12-12

    Healing of venous leg ulcers is improved by the use of compression bandaging but some venous ulcers remain unhealed, and some people are unsuitable for compression therapy. Pentoxifylline, a drug which helps blood flow, has been used to treat venous leg ulcers. To assess the effects of pentoxifylline (oxpentifylline or Trental 400) for treating venous leg ulcers, compared with a placebo or other therapies, in the presence or absence of compression therapy. For this fifth update we searched the Cochrane Wounds Group Specialised Register (searched 20 July 2012); The Cochrane Central Register of Controlled Trials (CENTRAL) (The Cochrane Library 2012, Issue 7); Ovid MEDLINE (2010 to July Week 2 2012); Ovid MEDLINE (In-Process & Other Non-Indexed Citations, July 19, 2012); Ovid EMBASE (2010 to 2012 Week 28); and EBSCO CINAHL (2010 to July 13 2012). Randomised trials comparing pentoxifylline with placebo or other therapy in the presence or absence of compression, in people with venous leg ulcers. One review author extracted and summarised details from eligible trials using a coding sheet. One other review author independently verified data extraction. No new trials were identified for this update. We included twelve trials involving 864 participants. The quality of trials was variable. Eleven trials compared pentoxifylline with placebo or no treatment. Pentoxifylline is more effective than placebo in terms of complete ulcer healing or significant improvement (RR 1.70, 95% CI 1.30 to 2.24). Pentoxifylline plus compression is more effective than placebo plus compression (RR 1.56, 95% CI 1.14 to 2.13). Pentoxifylline in the absence of compression appears to be more effective than placebo or no treatment (RR 2.25, 95% CI 1.49 to 3.39).More adverse effects were reported in people receiving pentoxifylline (RR 1.56, 95% CI 1.10 to 2.22). Nearly three-quarters (72%) of the reported adverse effects were gastrointestinal. Pentoxifylline is an effective adjunct to compression

  8. Cerebrospinal fluid drainage for syringomyelia.

    PubMed

    Williams, B; Sgouros, S; Nenji, E

    1995-12-01

    Twenty-eight years of experience with syringomyelia of various causes in the syringomyelia clinic at the Midland Centre for Neurosurgery and Neurology has provided a database of 723 patients, mostly adults, with either hindbrain herniation, syringomyelia or both. Treatment of syringomyelia by drainage has never been the optimum primary treatment on the basis that the cavity is usually secondary to some other disturbance of the cerebrospinal fluid pathways. Over this period 73 patients had either syrinx drainage (56 syringopleural, 14 syringo-subarachnoid shunts) or other procedure such as myelotomy and cord transection. Ten years after operation only 53.5% and 50% of these two groups respectively continued to remain clinically stable. A complication rate of 15.7% included fatal haemorrhage, infection and displacement of drains. At second operation or necropsy at least 5% of shunts were found to be blocked. All the shunts were inserted without a valve and the lowering of the intrasyrinx pressure has therefore been energetic when the lower end of the drainage tube has been taken to the pleural or peritoneal cavities. This produced collapse of the cord cavities around the tip of the drainage tube and increased the likelihood of blockage. If the mechanisms which were responsible for the syringomyelia were still operative then recurrence was likely to occur alongside the drainage tube leaving the tube immured in the wall of the syrinx cavity. When hydrocephalus was present, in addition treatment of the hydrocephalus by a valved shunt to the peritoneum or to the right atrium was often effective in improving the syringomyelia. This treatment has also been used in patients without hydrocephalus. The mechanisms of improvement were unclear but this treatment stratagem has nevertheless been employed in 45 cases. In 30 out of these 45 cases the drainage of cerebrospinal fluid from outside the syrinx cavities seemed to be worthwhile; 10 patients suffered some form of

  9. Noninvasive measurement of central venous pressure

    NASA Technical Reports Server (NTRS)

    Webster, J. G.; Mastenbrook, S. M., Jr.

    1972-01-01

    A technique for the noninvasive measurement of CVP in man was developed. The method involves monitoring venous velocity at a point in the periphery with a transcutaneous Doppler ultrasonic velocity meter while the patient performs a forced expiratory maneuver. The idea is the CVP is related to the value of pressure measured at the mouth which just stops the flow in the vein. Two improvements were made over the original procedure. First, the site of venous velocity measurement was shifted from a vein at the antecubital fossa (elbow) to the right external jugular vein in the neck. This allows for sensing more readily events occurring in the central veins. Secondly, and perhaps most significantly, a procedure for obtaining a curve of relative mean venous velocity vs mouth pressure was developed.

  10. Percutaneous Treatment of Central Venous Stenosis in Hemodialysis Patients: Long-Term Outcomes

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Kim, Young Chul; Won, Jong Yun, E-mail: jywon@yumc.yonsei.ac.kr; Choi, Sun Young

    2009-03-15

    The purpose of this study was to evaluate the long-term outcomes of endovascular treatment of central venous stenosis in patients with arteriovenous fistulas (AVFs) for hemodialysis. Five hundred sixty-three patients with AVFs who were referred for a fistulogram were enrolled in this study. Among them, 44 patients showed stenosis (n = 35) or occlusions (n = 9) in the central vein. For the initial treatment, 26 patients underwent percutaneous transluminal angioplasty (PTA) and 15 patients underwent stent placements. Periods between AVF formation and first intervention ranged from 3 to 144 months. Each patient was followed for 14 to 60 months.more » Procedures were successful in 41 of 44 patients (93.2%). Primary patency rates for PTA at 12 and 36 months were 52.1% and 20.0%, and assisted primary patency rates were 77.8% and 33.3%, respectively. Primary patency rates for stent at 12 and 36 months were 46.7% and 6.7%, and assisted primary patency rates were 60.0% and 20.0%, respectively. Fifteen of 26 patients with PTAs underwent repeated interventions because of restenosis. Fourteen of 15 patients with a stent underwent repeated interventions because of restenosis and combined migration (n = 1) and shortening (n = 6) of the first stent. There was no significant difference in patency between PTAs and stent placement (p > 0.05). Average AVF patency duration was 61.8 months and average number of endovascular treatments was 2.12. In conclusion, endovascular treatments of central venous stenosis could lengthen the available period of AVFs. There was no significant difference in patency between PTAs and stent placement.« less

  11. [The unnecessary application of central venous catheterization in surgical patients].

    PubMed

    Uemura, Keiko; Inoue, Satoki; Kawaguchi, Masahiko

    2018-04-06

    Perioperative physicians occasionally encounter situations where central venous catheters placed preoperatively turn out to be unnecessary. The purpose of this retrospective study is to identify the unnecessary application of central venous catheter placement and determine the factors associated with the unnecessary application of central venous catheter placement. Using data from institutional perioperative central venous catheter surveillance, we analysed data from 1,141 patients who underwent central venous catheter placement. We reviewed the central venous catheter registry and medical charts and allocated registered patients into those with the proper or with unnecessary application of central venous catheter according to standard indications. Multivariate analysis was used to identify factors associated with the unnecessary application of central venous catheter placement. In 107 patients, representing 9.38% of the overall population, we identified the unnecessary application of central venous catheter placement. Multivariate analysis identified emergencies at night or on holidays (odds ratio [OR] 2.109, 95% confidence interval [95% CI] 1.021-4.359), low surgical risk (OR=1.729, 95% CI 1.038-2.881), short duration of anesthesia (OR=0.961/10min increase, 95% CI 0.945-0.979), and postoperative care outside of the intensive care unit (OR=2.197, 95% CI 1.402-3.441) all to be independently associated with the unnecessary application of catheterization. Complications related to central venous catheter placement when the procedure consequently turned out to be unnecessary were frequently observed (9/107) compared with when the procedure was necessary (40/1034) (p=0.032, OR=2.282, 95% CI 1.076-4.842). However, the subsequent multivariate logistic model did not hold this significant difference (p=0.0536, OR=2.115, 95% CI 0.988-4.526). More careful consideration for the application of central venous catheter is required in cases of emergency surgery at night or on

  12. Radiation hard vacuum switch

    DOEpatents

    Boettcher, Gordon E.

    1990-01-01

    A vacuum switch with an isolated trigger probe which is not directly connected to the switching electrodes. The vacuum switch within the plasmatron is triggered by plasma expansion initiated by the trigger probe which travels through an opening to reach the vacuum switch elements. The plasma arc created is directed by the opening to the space between the anode and cathode of the vacuum switch to cause conduction.

  13. Radiation hard vacuum switch

    DOEpatents

    Boettcher, Gordon E.

    1990-03-06

    A vacuum switch with an isolated trigger probe which is not directly connected to the switching electrodes. The vacuum switch within the plasmatron is triggered by plasma expansion initiated by the trigger probe which travels through an opening to reach the vacuum switch elements. The plasma arc created is directed by the opening to the space between the anode and cathode of the vacuum switch to cause conduction.

  14. Unilateral Loss of Spontaneous Venous Pulsations in an Astronaut

    NASA Technical Reports Server (NTRS)

    Mader, Thomas H.; Gibson, C. Robert; Lee, Andrew G.; Patel, Nimesh; Hart, Steven; Pettit, Donald R.

    2014-01-01

    Spontaneous venous pulsations seen on the optic nerve head (optic disc) are presumed to be caused by fluctuations in the pressure gradient between the intraocular and retrolaminar venous systems. The disappearance of previously documented spontaneous venous pulsations is a well-recognized clinical sign usually associated with a rise in intracranial pressure and a concomitant bilateral elevation of pressure in the subarachnoid space surrounding the optic nerves. In this correspondence we report the unilateral loss of spontaneous venous pulsations in an astronaut 5 months into a long duration space flight. We documented a normal lumbar puncture opening pressure 8 days post mission. The spontaneous venous pulsations were also documented to be absent 21 months following return to Earth.. We hypothesize that these changes may have resulted from a chronic unilateral rise in optic nerve sheath pressure caused by a microgravity-induced optic nerve sheath compartment syndrome.

  15. Venous leg ulcers

    PubMed Central

    2008-01-01

    Introduction Leg ulcers usually occur secondary to venous reflux or obstruction, but 20% of people with leg ulcers have arterial disease, with or without venous disorders. Between 1.5 and 3.0/1000 people have active leg ulcers. Prevalence increases with age to about 20/1000 in people aged over 80 years. Methods and outcomes We conducted a systematic review and aimed to answer the following clinical questions: What are the effects of standard treatments, adjuvant treatments, and organisational interventions for venous leg ulcers? What are the effects of interventions to prevent recurrence of venous leg ulcers? We searched: Medline, Embase, The Cochrane Library, and other important databases up to September 2007 (BMJ Clinical Evidence reviews are updated periodically, please check our website for the most up-to-date version of this review). We included harms alerts from relevant organisations such as the US Food and Drug Administration (FDA) and the UK Medicines and Healthcare products Regulatory Agency (MHRA). Results We found 80 systematic reviews, RCTs, or observational studies that met our inclusion criteria. We performed a GRADE evaluation of the quality of evidence for interventions. Conclusions In this systematic review we present information relating to the effectiveness and safety of the following interventions: compression bandages and stockings, cultured allogenic (single or bilayer) skin replacement, debriding agents, dressings (cellulose, collagen, film, foam, hyaluronic acid-derived, semi-occlusive alginate), hydrocolloid (occlusive) dressings in the presence of compression, intermittent pneumatic compression, intravenous prostaglandin E1, larval therapy, laser treatment (low-level), leg ulcer clinics, multilayer elastic system, multilayer elastomeric (or non-elastomeric) high-compression regimens or bandages, oral treatments (aspirin, flavonoids, pentoxifylline, rutosides, stanozolol, sulodexide, thromboxane alpha2 antagonists, zinc), peri

  16. "Black butterfly" sign on T2*-weighted and susceptibility-weighted imaging: A novel finding of chronic venous congestion of the brain stem and spinal cord associated with dural arteriovenous fistulas.

    PubMed

    Enokizono, Mikako; Sato, Noriko; Morikawa, Minoru; Kimura, Yukio; Sugiyama, Atsuhiko; Maekawa, Tomoko; Sone, Daichi; Takewaki, Daiki; Okamoto, Tomoko; Takahashi, Yuji; Horie, Nobutaka; Matsuo, Takayuki

    2017-08-15

    A dural arteriovenous fistula (DAVF) with spinal perimedullary venous drainage can cause progressive myelopathy, and it is sometimes incorrectly diagnosed as another spinal cord disease. Here we report the cases of three individuals with a DAVF (one craniocervical junction DAVF and two tentorial DAVFs) with progressive myelopathy showing unique magnetic resonance (MR) imaging findings. MR T2*WI or susceptibility-weighted imaging (SWI) demonstrated symmetrical dark signal intensity lesions predominantly in the dorsal aspect of medulla and the central gray matter of cervical spinal cord that showed the "black butterfly" silhouette. Cerebral angiography revealed DAVFs draining into anterior and posterior spinal veins. Dark signals on T2*WI and SWI were presumed to be hemorrhages, which were probably caused by prolonged venous congestion. Identifying this "black butterfly" sign can facilitate the diagnosis of DAVF, differentiating DAVF from other spinal cord diseases such as demyelinating lesions and neoplasms. Copyright © 2017 Elsevier B.V. All rights reserved.

  17. Variability in alignment of central venous pressure transducer to physiologic reference point in the intensive care unit-A descriptive and correlational study.

    PubMed

    Sjödin, Carl; Sondergaard, Soren; Johansson, Lotta

    2018-06-01

    The phlebostatic axis is the most commonly used anatomical external reference point for central venous pressure measurements. Deviation in the central venous pressure transducer alignment from the phlebostatic axis causes inadequate pressure readings, which may affect treatment decisions for critically ill patients in intensive care units. The primary aim of the study was to assess the variability in central venous pressure transducer levelling in the intensive care unit. We also assessed whether patient characteristics impacted on central venous pressure transducer alignment deviation. A sample of 61 critical care nurses was recruited and asked to place a transducer at the appropriate level for central venous pressure measurement. The measurements were performed in the intensive care unit on critically ill patients in supine and Fowler's positions. The variability among the participants using eyeball levelling and a laser levelling device was calculated in both sessions and adjusted for patient characteristics. A significant variation was found among critical care nurses in the horizontal levelling of the pressure transducer placement when measuring central venous pressure in the intensive care unit. Using a laser levelling device did not reduce the deviation from the phlebostatic axis. Patient characteristics had little impact on the deviation in the measurements. The anatomical external landmark for the phlebostatic axis varied between critical care nurses, as the variation in the central venous pressure transducer placement was not reduced with a laser levelling device. Standardisation of a zero-level for vascular pressures should be considered to reduce the variability in vascular pressure readings in the intensive care unit to improve patient treatment decisions. Further studies are needed to evaluate critical care nurses' knowledge and use of central venous pressure monitoring and whether assistive tools and/or routines can improve the accuracy in vascular

  18. Long-term outcomes of sandwich ventral hernia repair paired with hybrid vacuum-assisted closure.

    PubMed

    Hicks, Caitlin W; Poruk, Katherine E; Baltodano, Pablo A; Soares, Kevin C; Azoury, Said C; Cooney, Carisa M; Cornell, Peter; Eckhauser, Frederic E

    2016-08-01

    Sandwich ventral hernia repair (SVHR) may reduce ventral hernia recurrence rates, although with an increased risk of surgical site occurrences (SSOs) and surgical site infections (SSIs). Previously, we found that a modified negative pressure wound therapy (hybrid vacuum-assisted closure [HVAC]) system reduced SSOs and SSIs after ventral hernia repair. We aimed to describe our outcomes after SVHR paired with HVAC closure. We conducted a 4-y retrospective review of all complex SVHRs (biologic mesh underlay and synthetic mesh overlay) with HVAC closure performed at our institution by a single surgeon. All patients had fascial defects that could not be reapproximated primarily using anterior component separation. Descriptive statistics were used to report the incidence of postoperative complications and hernia recurrence. A total of 60 patients (59.3 ± 11.4 y, 58.3% male, 75% American Society of Anesthesiologists class ≥3) with complex ventral hernias being underwent sandwich repair with HVAC closure. Major postoperative morbidity (Dindo-Clavien class ≥3) occurred in 14 (23.3%) patients, but incidence of SSO (n = 13, 21.7%) and SSI (n = 4, 6.7%) was low compared with historical reports. Median follow-up time for all patients was 12 mo (interquartile range 5.8-26.5 mo). Hernia recurrence occurred in eight patients (13.3%) after a median time of 20.6 months (interquartile range 16.4- 25.4 months). Use of a dual layer sandwich repair for complex abdominal wall reconstruction is associated with low rates of hernia recurrence at 1 year postoperatively. The addition of the HVAC closure system may reduce the risk of SSOs and SSIs previously reported with this technique and deserves consideration in future prospective studies assessing optimization of ventral hernia repair approaches. Copyright © 2016 Elsevier Inc. All rights reserved.

  19. Vacuum-assisted cell loading enables shear-free mammalian microfluidic culture

    PubMed Central

    Kolnik, Martin; Tsimring, Lev S; Hasty, Je

    2012-01-01

    Microfluidic perfusion cultures for mammalian cells provide a novel means for probing single-cell behavior but require the management of culture parameters such as flow-induced shear stress. Methods to eliminate shear stress generally focus on capturing cells in regions with high resistance to fluid flow. Here, we present a novel trapping design to easily and reliably load a high density of cells into culture chambers that are extremely isolated from potentially damaging flow effects. We utilize a transient on-chip vacuum to remove air from the culture chambers and rapidly replace the volume with a liquid cell suspension. We demonstrate the ability of this simple and robust method to load and culture three commonly used cell lines. We show how the incorporation of an on-chip function generator can be used for dynamic stimulation of cells during long-term continuous perfusion culture. PMID:22961584

  20. Venous thrombosis after hallux valgus surgery.

    PubMed

    Radl, Roman; Kastner, Norbert; Aigner, Christian; Portugaller, Horst; Schreyer, Herbert; Windhager, Reinhard

    2003-07-01

    Although surgery for the treatment of hallux valgus is frequently performed, the exact rate of deep vein thrombosis following this procedure is unknown. We performed a single-center, prospective, phlebographically controlled study to quantify the rate of venous thrombosis following operative correction of hallux valgus. Consecutive patients undergoing chevron bunionectomy for correction of hallux valgus deformity were enrolled in the study. Patients with clinical or hematological risk factors for venous thrombosis were excluded. One hundred patients with a mean age of 48.9 years were operated on and did not receive medical prophylaxis against thrombosis. All patients were assessed with phlebography at a mean of twenty-nine days postoperatively. Venous thrombosis was found in four patients (4%). The mean age of these patients (and standard deviation) was 61.7 +/- 6.1 years compared with a mean age of 48.4 +/- 13.9 years for the patients in whom thrombosis did not develop (p = 0.034). Patients are at a low risk for venous thrombosis following surgical treatment of hallux valgus. The need for prophylaxis against thrombosis should be calculated individually for each patient according to his or her known level of risk. Routine medical prophylaxis against thrombosis might be justified for patients over the age of sixty years.

  1. Economic evaluation of Vacuum Assisted Closure® Therapy for the treatment of diabetic foot ulcers in France.

    PubMed

    Whitehead, Sarah J; Forest-Bendien, Véronique L; Richard, Jean-Louis; Halimi, Serge; Van, Georges Ha; Trueman, Paul

    2011-02-01

    The objective of the study was to assess the cost-effectiveness of Vacuum Assisted Closure® (V.A.C.®) Therapy compared with advanced wound care (AWC) for the treatment of diabetic foot ulcers (DFUs) in France. A cost-effectiveness model intended to reflect the management of DFUs was updated for the French setting. The Markov model follows the progression of 1000 hypothetical patients over a 1-year period. The model was populated with French-specific data, obtained from published sources and clinical experts. The analysis evaluated costs and health outcomes, in terms of quality-adjusted life-years (QALYs), wounds healed and amputations, from the perspective of the payer. The patients treated with V.A.C.® Therapy experienced more QALYs (0.787 versus 0.784) and improved healing rates (50.2% versus 48.5%) at a lower total cost of care (€24,881 versus €28,855 per patient per year) when compared with AWC. Sensitivity analyses conducted around key model parameters indicated that the results were affected by hospital resource use and costs. DFU treatment using V.A.C.® Therapy in France was associated with lower costs, additional QALYs, more healed ulcers and fewer amputations than treatment with AWC. V.A.C.® Therapy was therefore found to be the dominant treatment option. © 2010 The Authors. © 2010 Blackwell Publishing Ltd and Medicalhelplines.com Inc.

  2. The Effect of Vacuum-Assisted Closure on the Bacterial Load and Type of Bacteria: A Systematic Review

    PubMed Central

    Patmo, Aryan S.P.; Krijnen, Pieta; Tuinebreijer, Wim E.; Breederveld, Roelf S.

    2014-01-01

    Significance: A high bacterial load interferes with the healing process of a wound. Vacuum-assisted closure (VAC) is a wound healing therapy that utilizes a dressing system that continuously or intermittently applies a negative pressure to the wound surface. Recent Advances: VAC stimulates wound healing, but data on changes in the bacterial load and changes in the bacterial spectrum are scarce. Critical Issues: While VAC supposedly removes bacteria from the treated wounds and therefore reduces the risk of infection, this relationship has not yet been clinically proven. If VAC increases the bacterial load instead of decreasing it, then this may be a reason not to use VAC on certain types of wounds. Only seven small and heterogeneous studies reporting on the relationship between VAC usage and the bacterial load and type of bacteria in the treated wounds in clinical practice were found in the literature. Although there is some low quality evidence that VAC therapy does not change the bacterial load, no definite conclusions on changes in the bacterial load and type of bacteria during VAC can be drawn. Future Directions: Prospectively monitoring changes in the bacterial load and bacterial spectrum in patients that will receive VAC treatment on indication might be an effective way to find out whether it should indeed be used on specific wounds. PMID:24804158

  3. Vacuum-assisted closure therapy increases local interleukin-8 and vascular endothelial growth factor levels in traumatic wounds.

    PubMed

    Labler, Ludwig; Rancan, Mario; Mica, Ladislav; Härter, Luc; Mihic-Probst, Daniela; Keel, Marius

    2009-03-01

    Clinical observations are suggesting accelerated granulation tissue formation in traumatic wounds treated with vacuum-assisted closure (VAC). Aim of this study was to determine the impact of VAC therapy versus alternative Epigard application on local inflammation and neovascularization in traumatic soft tissue wounds. Thirty-two patients with traumatic wounds requiring temporary coverage (VAC n = 16; Epigard n = 16) were included. At each change of dressing, samples of wound fluid and serum were collected (n = 80). The cytokines interleukin (IL)-6, IL-8, vascular endothelial growth factor (VEGF), and fibroblast growth factor-2 were measured by ELISA. Wound biopsies were examined histologically for inflammatory cells and degree of neovascularization present. All cytokines were found to be elevated in wound fluids during both VAC and Epigard treatment, whereas serum concentrations were negligible or not detectable. In wound fluids, significantly higher IL-8 (p < 0.001) and VEGF (p < 0.05) levels were detected during VAC therapy. Furthermore, histologic examination revealed increased neovascularization (p < 0.05) illustrated by CD31 and von Willebrand factor immunohistochemistry in wound biopsies of VAC treatment. In addition, there was an accumulation of neutrophils as well as an augmented expression of VEGF (p < 0.005) in VAC wound biopsies. This study suggests that VAC therapy of traumatic wounds leads to increased local IL-8 and VEGF concentrations, which may trigger accumulation of neutrophils and angiogenesis and thus, accelerate neovascularization.

  4. Vacuum fluctuations in an ancestor vacuum: A possible dark energy candidate

    NASA Astrophysics Data System (ADS)

    Aoki, Hajime; Iso, Satoshi; Lee, Da-Shin; Sekino, Yasuhiro; Yeh, Chen-Pin

    2018-02-01

    We consider an open universe created by bubble nucleation, and study possible effects of our "ancestor vacuum," a de Sitter space in which bubble nucleation occurred, on the present universe. We compute vacuum expectation values of the energy-momentum tensor for a minimally coupled scalar field, carefully taking into account the effect of the ancestor vacuum by the Euclidean prescription. We pay particular attention to the so-called supercurvature mode, a non-normalizable mode on a spatial slice of the open universe, which has been known to exist for sufficiently light fields. This mode decays in time most slowly, and may leave residual effects of the ancestor vacuum, potentially observable in the present universe. We point out that the vacuum energy of the quantum field can be regarded as dark energy if mass of the field is of order the present Hubble parameter or smaller. We obtain preliminary results for the dark energy equation of state w (z ) as a function of the redshift.

  5. On the feasibility of the computational modelling of the endoluminal vacuum-assisted closure of an oesophageal anastomotic leakage

    PubMed Central

    Bellomo, Facundo J.; Rosales, Iván; del Castillo, Luis F.; Sánchez, Ricardo; Turon, Pau

    2018-01-01

    Endoluminal vacuum-assisted closure (E-VAC) is a promising therapy to treat anastomotic leakages of the oesophagus and bowel which are associated with high morbidity and mortality rates. An open-pore polyurethane foam is introduced into the leakage cavity and connected to a device that applies a suction pressure to accelerate the closure of the defect. Computational analysis of this healing process can advance our understanding of the biomechanical mechanisms at play. To this aim, we use a dual-stage finite-element analysis in which (i) the structural problem addresses the cavity reduction caused by the suction and (ii) a new constitutive formulation models tissue healing via permanent deformations coupled to a stiffness increase. The numerical implementation in an in-house code is described and a qualitative example illustrates the basic characteristics of the model. The computational model successfully reproduces the generic closure of an anastomotic leakage cavity, supporting the hypothesis that suction pressure promotes healing by means of the aforementioned mechanisms. However, the current framework needs to be enriched with empirical data to help advance device designs and treatment guidelines. Nonetheless, this conceptual study confirms that computational analysis can reproduce E-VAC of anastomotic leakages and establishes the bases for better understanding the mechanobiology of anastomotic defect healing. PMID:29515846

  6. Partial anomalous pulmonary venous return in Turner syndrome.

    PubMed

    van den Hoven, Allard T; Chelu, Raluca G; Duijnhouwer, Anthonie L; Demulier, Laurent; Devos, Daniel; Nieman, Koen; Witsenburg, Maarten; van den Bosch, Annemien E; Loeys, Bart L; van Hagen, Iris M; Roos-Hesselink, Jolien W

    2017-10-01

    The aim of this study is to describe the prevalence, anatomy, associations and clinical impact of partial anomalous pulmonary venous return in patients with Turner syndrome. All Turner patients who presented at our Turner clinic, between January 2007 and October 2015 were included in this study and underwent ECG, echocardiography and advanced imaging such as cardiac magnetic resonance or computed tomography as part of their regular clinical workup. All imaging was re-evaluated and detailed anatomy was described. Partial anomalous pulmonary venous return was diagnosed in 24 (25%) out of 96 Turner patients included and 14 (58%) of these 24 partial anomalous pulmonary venous return had not been reported previously. Right atrial or ventricular dilatation was present in 11 (46%) of 24 partial anomalous pulmonary venous return patients. When studied with advanced imaging modalities and looked for with specific attention, PAPVR is found in 1 out of 4 Turner patients. Half of these patients had right atrial and/or ventricular dilatation. Evaluation of pulmonary venous return should be included in the standard protocol in all Turner patients. Copyright © 2017. Published by Elsevier B.V.

  7. A survey of current practice of vascular surgeons in venous disease management.

    PubMed

    Bush, Ruth L; Gloviczki, Peter

    2013-01-01

    Acute venous thromboembolism and chronic venous diseases are common conditions that affect a large proportion of the United States population. The diagnosis of venous disease has improved, and the treatment options have rapidly evolved over the past decade. To date, it is unclear to what extent vascular surgeons have become involved in the modern management of venous disorders. This survey was undertaken to explore the current interest and practice of vascular surgeons in the contemporary care of venous disease. A survey was administered via a web-based platform to active and candidate members of the Society for Vascular Surgery (SVS). The survey included 30 questions investigating the characteristics of venous surgeons and scope of venous practice. Open-ended questions were also included for commentary. A total of 1879 surveys were sent to SVS members nationwide, and 385 members participated (response rate of 20.5%). The participants were mostly men (89.6%) with 37.7% practicing in an academic setting and 59.2% in private practice. The respondents treated superficial veins (92.9%) and deep veins (85.8%) in clinical practice, with 89.9% having their own vascular laboratory. A wide spectrum of interventions for superficial (91.9%), deep (85.8%), and perforator veins (52.7% endovenous, 19.4% subfascial endoscopic perforator surgery) are being performed by respondents. Only 26.2% had learned endovenous thermal ablation in their training program; however, over 96% of those performing venous interventions utilized this technique. Overall, the majority (85.5%) devoted 50% or less of practice to venous disorders. Respondents indicated that limitations to expansion of vein practices mainly involved challenges with third party payers, local competition, and existing large volumes of arterial interventions needing to be performed. Despite the widespread incorporation of venous disease into current vascular practices, 66.1% are not members of the American Venous Forum (AVF

  8. [Superficial venous thrombosis. A state of art].

    PubMed

    Sándor, Tamás

    2017-01-01

    For a long time superficial thrombophlebitis has been thought to be a rather benign condition. Recently, when duplex ultrasound technique is used for the diagnosis more and more often, the disease is proved to be more dangerous than anticipated. Thrombosis propagates to the deep veins in 6-44% and pulmonary embolism was observed on the patients in 1,5-33%. We can calculate venous thromboembolic complications on every fourth patient. Diagnosis is clinical, but duplex ultrasound examination is mandatory, for estimation of the thrombus extent, for exclusion of the deep venous thrombosis and for follow up. Both legs should be checked with ultrasound, because simultaneous deep venous thrombosis can develop on the contralateral limb. Two different forms can be distinguished: superficial venous thrombosis with, or without varicose veins. In cases of spontaneous, non varicous form, especially when the process is migrating or recurrent, a careful clinical examination is necessery for exclusion of malignant diseases and thrombophilia. The treatment options are summarised on the basis of recent international consensus statements. The American and German guidelines are similar. Compression and mobilisation are cornerstones of the therapy. For a short segment thrombosis non steroidal antiinflammatory drugs are effective. For longer segments low molecular-weight heparins are preferred. Information on the effect of the novel oral anticoagulants for the therapy is lacking but they may appear to be effective in the future for this indication. When thrombus is close to the sapheno-femoral or sapheno-popliteal junction crossectomy (high ligation), or low molecular-weight heparin in therapeutic doses are indicated. The term superficial thrombophlebitis should be discouraged, because inflammation and infection is not the primary pathology. It should be called correctly superficial venous thrombosis in order to avoid the unnecessary administration of antibiotics and the misconception

  9. Comparison of Medpor coated tear drainage tube versus silicon tear drainage tube in conjunctivodacryocystorhinostomy: problems and solutions.

    PubMed

    Sendul, Selam Yekta; Cagatay, Halil Huseyin; Dirim, Burcu; Demir, Mehmet; Yıldız, Ali Atakhan; Acar, Zeynep; Cinar, Sonmez; Guven, Dilek

    2014-01-01

    This study aims at comparing two different types of drainage tubes in conjunctivodacryocystorhinostomy, which are used for upper lacrimal system obstruction or damage, with respect to their respective postoperative problems and solutions. Nineteen eyes of 17 patients who underwent conjunctivodacryocystorhinostomy (CDCR) or conjunctivorhinostomy (CR) surgery with a Medpor coated tear drainage tube or silicon tube placement between October, 2010, and February, 2014, were included in this retrospective comparative study. In the initial surgery, Medpor coated tear drainage tubes were used in 11 eyes by CDCR, whereas silicon tear drainage tubes were implanted into 2 eyes by CR and 6 eyes by CDCR. In group 1, proximal and distal obstructions developed postoperatively in 4 eyes, while 1 eye showed tube malposition and 3 eyes developed luminal obstruction by debris 3 times. In group 2, tube extrusion developed in 4 eyes, whereas tube malposition developed in 6 eyes and luminal obstruction by debris developed in 6 eyes at different times, for a total of 20 times. In our study, the most significant complication we observed in the use of silicon tear drainage tubes was tube extrusion,whereas the leading complication related to the use of Medpor coated tear drainage tubes was tube obstruction.

  10. Comparison of Medpor Coated Tear Drainage Tube versus Silicon Tear Drainage Tube in Conjunctivodacryocystorhinostomy: Problems and Solutions

    PubMed Central

    Sendul, Selam Yekta; Cagatay, Halil Huseyin; Dirim, Burcu; Demir, Mehmet; Yıldız, Ali Atakhan; Acar, Zeynep; Cinar, Sonmez; Guven, Dilek

    2014-01-01

    Purpose. This study aims at comparing two different types of drainage tubes in conjunctivodacryocystorhinostomy, which are used for upper lacrimal system obstruction or damage, with respect to their respective postoperative problems and solutions. Methods. Nineteen eyes of 17 patients who underwent conjunctivodacryocystorhinostomy (CDCR) or conjunctivorhinostomy (CR) surgery with a Medpor coated tear drainage tube or silicon tube placement between October, 2010, and February, 2014, were included in this retrospective comparative study. Results. In the initial surgery, Medpor coated tear drainage tubes were used in 11 eyes by CDCR, whereas silicon tear drainage tubes were implanted into 2 eyes by CR and 6 eyes by CDCR. In group 1, proximal and distal obstructions developed postoperatively in 4 eyes, while 1 eye showed tube malposition and 3 eyes developed luminal obstruction by debris 3 times. In group 2, tube extrusion developed in 4 eyes, whereas tube malposition developed in 6 eyes and luminal obstruction by debris developed in 6 eyes at different times, for a total of 20 times. Conclusions. In our study, the most significant complication we observed in the use of silicon tear drainage tubes was tube extrusion,whereas the leading complication related to the use of Medpor coated tear drainage tubes was tube obstruction. PMID:25379518

  11. Is peritoneal drainage essential after pancreatic surgery?

    PubMed Central

    Huan, Lu; Fei, Qilin; Lin, Huapeng; Wan, Lun; Li, Yue

    2017-01-01

    Abstract Aim: Our objective is to assess the function of peritoneal drainage, which is placed after pancreatic surgery. Background: With the medical advancement some study put forward that peritoneal drainage is not the necessary after pancreatic surgery; it cannot improve the complications of postoperation even leading to more infection and so on. However, there is no one study can clear and definite whether omitting the drainage after surgery or not. Method: Searching databases consist of all kinds of searching tools, such as Medline, The Cochrane Library, Embase, PubMed, etc. All the included studies should meet our demand of this meta-analysis. In the all interest outcomes blow we take the full advantage of RevMan5 to assess, the main measure is odds ratio (OR) with 95% confidence, the publication bias are assessed by Egger test and Begg test. Result: The rate of postoperative pancreatic fistula (POPF) in no drainage group is much lower than that in routine drainage group (OR = 0.47, I2 = 43%, P < .00001). The result of the 2 randomized controlled trials (RCTs) in this pool are almost accord with the former (OR = 0.57, I2 = 0%, P = .05). In subgroup the result suggest that the peritoneal drainage can increase the morbidity (OR = 0.71, I2 = 15%, P = .0002) after pancreaticoduodenectomy (PD), but reduce the mortality (OR = 1.92, I2 = 8%, P = .03) after PD. In distal pancreatectomy (DP) the rate of POPF and clinically relevant pancreatic fistula (CR-PF) is lower without drainage; there is no significant difference in the CR-PF, hospital stay, intra-abdominal abscess, radiologic invention, and the reoperation. Conclusion: In the current meta-analysis, we cannot make a clear conclusion whether to abandon the routine drainage or not, but from the subgroup we can see something is safer than nothing to routine peritoneal drainage. And the patients who underwent DP can attempt to omit the drainage. But it still needs more

  12. Extrinsic cerebral venous sinus obstruction resulting in intracranial hypertension

    PubMed Central

    Goldsmith, P; Burn, D; Coulthard, A; Jenkins, A

    1999-01-01

    We report the case of a 70-year-old man reporting with headache and visual disturbances who was being treated for prostate cancer. Investigations showed him to have intracranial hypertension caused by venous sinus obstruction. Patients with metastatic disease and raised intracranial pressure in the absence of focal signs should be considered as possible cases of venous outflow obstruction.


Keywords: intracranial hypertension; venous sinus thrombosis; malignancy PMID:10616691

  13. Simple model of foam drainage

    NASA Astrophysics Data System (ADS)

    Fortes, M. A.; Coughlan, S.

    1994-10-01

    A simple model of foam drainage is introduced in which the Plateau borders and quadruple junctions are identified with pools that discharge through channels to pools underneath. The flow is driven by gravity and there are friction losses in the exhausting channels. The equation of Bernoulli combined with the Hagen-Poiseuille equation is applied to describe the flow. The area of the cross section of the exhausting channels can be taken as a constant or may vary during drainage. The predictions of the model are compared with standard drainage curves and with the results of a recently reported experiment in which additional liquid is supplied at the top of the froth.

  14. Vacuum Virtues

    ERIC Educational Resources Information Center

    Rathey, Allen

    2007-01-01

    Upright vacuums, like cars, vary in quality, features and performance. Like automobiles, some uprights are reliable, others may be problematic, and some become a problem as a result of neglect or improper use. So, how do education institutions make an informed choice and, having done so, ensure that an upright vacuum goes the distance? In this…

  15. Outcomes of Heimlich valve drainage in dogs.

    PubMed

    Salci, H; Bayram, A S; Gorgul, O S

    2009-04-01

    Retrospective study of the outcomes of Heimlich valve drainage in dogs. Medical records of the past 3 years were retrospectively reviewed. Heimlich valve drainage was used in 34 dogs (median body weight 30 +/- 5 kg): lobectomy (n = 15), pneumonectomy (n = 9), intrathoracic oesophageal surgery (n = 2), diaphragmatic hernia repair (n = 1), traumatic open pneumothorax (n = 2), bilobectomy (n = 2), ligation of the thoracic duct (n = 1), and chylothorax and pneumothorax (n = 1 each). Evacuation of air and/or fluid from the pleural cavity was performed with the Heimlich valve following thoracostomy tube insertion. During drainage, the dogs were closely monitored for possible respiratory failure. Termination of Heimlich valve drainage was controlled with underwater seal drainage and assessed with thoracic radiography. Negative intrathoracic pressure was provided in 29 dogs without any complications. Post pneumonectomy respiratory syncope and post lobectomy massive hemothorax, which did not originate from the Heimlich valve, were the only postoperative complications. Dysfunction of the valve diaphragm, open pneumothorax and intrathoracic localisation of an acute gastric dilatation-volvulus syndrome caused by a left-sided diaphragmatic hernia following pneumonectomy were the Heimlich valve drainage complications. The Heimlich valve can be used as a continuous drainage device in dogs, but the complications reported here should be considered by veterinary practitioners.

  16. Geohydrologic reconnaissance of drainage wells in Florida

    USGS Publications Warehouse

    Kimrey, J.O.; Fayard, L.D.

    1984-01-01

    Drainage wells are used to inject surface waters directly into an aquifer, or shallow ground waters directly into a deeper aquifer, primarily by gravity. Such wells in Florida may be grouped into two broad types: (1) surface-water injection wells, and (2) interaquifer connector wells. Drainage wells of the first type are further categorized as either Floridan aquifer drainage wells or Biscayne aquifer drainage wells. Floridan aquifer drainage wells are commonly used to supplement drainage for urban areas in karst terranes of central and north Florida. Data are available for 25 wells in the Ocala, Live Oak, and Orlando areas that allow comparison of the quality of water samples from these Floridan aquifer drainage wells with allowable contaminant levels. Comparison indicates that maximum contaminant levels for turbidity, color, and iron, manganese, and lead concentrations are equaled or exceeded in some drainage-well samples, and relatively high counts for coliform bacteria are present in most wells. Biscayne aquifer drainage wells are used locally to dispose of stormwater runoff and other surplus water in southeast Florida, where large numbers of these wells have been permitted in Dade and Broward Counties. The majority of these wells are used to dispose of water from swimming pools or to dispose of heated water from air-conditioning units. The use of Biscayne aquifer drainage wells may have minimal effect on aquifer potability so long as injection of runoff and industrial wates is restricted to zones where chloride concentrations exceed 1,500 milligrams per liter. Interaquifer connector wells are used in the phosphate mining areas of Polk and Hillsborough Counties, to drain mines and recharge the Floridan aquifer. Water-quality data available from 13 connector wells indicate that samples from most of these wells exceed standards values for iron concentration and turbidity. One well yielded a highly mineralized water, and samples from 6 of the other 12 wells exceed

  17. Lymphatic Leak Complicating Central Venous Catheter Insertion

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Barnacle, Alex M., E-mail: alexbarnacle@yahoo.co.uk; Kleidon, Tricia M.

    2005-12-15

    Many of the risks associated with central venous access are well recognized. We report a case of inadvertent lymphatic disruption during the insertion of a tunneled central venous catheter in a patient with raised left and right atrial pressures and severe pulmonary hypertension, which led to significant hemodynamic instability. To our knowledge, this rare complication is previously unreported.

  18. Mixed venous oxygen saturation monitoring revisited: thoughts for critical care nursing practice.

    PubMed

    Christensen, Martin

    2012-05-01

    Less invasive methods of determining cardiac output are now readily available. Using indicator dilution technique, for example has made it easier to continuously measure cardiac output because it uses the existing intra-arterial line. Therefore gone is the need for a pulmonary artery floatation catheter and with it the ability to measure left atrial and left ventricular work indices as well the ability to monitor and measure a mixed venous saturation (SvO(2)). The aim of this paper is to put forward the notion that SvO(2) provides valuable information about oxygen consumption and venous reserve; important measures in the critically ill to ensure oxygen supply meets cellular demand. In an attempt to portray this, a simplified example of the septic patient is offered to highlight the changing pathophysiological sequelae of the inflammatory process and its importance for monitoring SvO(2). SvO(2) monitoring, it could be argued, provides the gold standard for assessing arterial and venous oxygen indices in the critically ill. For the bedside ICU nurse the plethora of information inherent in SvO(2) monitoring could provide them with important data that will assist in averting potential problems with oxygen delivery and consumption. However, it has been suggested that central venous saturation (ScvO(2)) might be an attractive alternative to SvO(2) because of its less invasiveness and ease of obtaining a sample for analysis. There are problems with this approach and these are to do with where the catheter tip is sited and the nature of the venous admixture at this site. Studies have shown that ScvO(2) is less accurate than SvO(2) and should not be used as a sole guiding variable for decision-making. These studies have demonstrated that there is an unacceptably wide range in variance between ScvO(2) and SvO(2) and this is dependent on the presenting disease, in some cases SvO(2) will be significantly lower than ScvO(2). Whilst newer technologies have been developed to

  19. Postoperative drainage in head and neck surgery.

    PubMed

    Amir, Ida; Morar, Pradeep; Belloso, Antonio

    2010-11-01

    A major factor affecting patients' length of hospitalisation following head and neck surgery remains the use of surgical drains. The optimal time to remove these drains has not been well defined. A routine practice is to measure the drainage every 24 h and remove the drain when daily drainage falls below 25 ml. This study aims to determine whether drainage measurement at shorter intervals decreases the time to drain removal and hence the length of in-patient stays. A 6-month prospective observational study was performed. The inclusion criteria were patients who underwent head and neck surgery without neck dissection and had a closed suction drain inserted. Drainage rates were measured at 8-hourly intervals. Drains were removed when drainage-rate was ≤ 1 ml/h over an 8-h period. A total of 43 patients were evaluated. The highest drainage rate occurred in the first 8 postoperative hours and decreased significantly in the subsequent hours. The median drainage rates at 8, 16, 24, 32 and 40 postoperative hours were 3.375, 1, 0, 0 and 0 ml/h, respectively. Applying our new removal criteria of ≤ 1 ml/h drainage rate, the drains were removed in 22 (51%) patients at the 16th postoperative hour; 37 (86%) were removed by 24 h after operation. In comparison, only nine (20.9%) patients could potentially be discharged the day after surgery if previous criteria of ≤ 25 ml/24-h were used to decide on drain removal. Our 8-hourly drainage-rate monitoring has facilitated safe earlier discharge of an additional 28 (65%) patients on the day after surgery. This has led to improvement in patient care, better optimisation of hospital resources and resulted in positive economic implications to the department.

  20. Tapping but not massage enhances vasodilation and improves venous palpation of cutaneous veins.

    PubMed

    Ichimura, Mika; Sasaki, Shinsuke; Mori, Masaharu; Ogino, Tetsuya

    2015-01-01

    This paper investigated whether tapping on the median cubital vein or massaging the forearm was more effective in obtaining better venous palpation for venipuncture. Forty healthy volunteers in their twenties were subjected to tapping (10 times in 5 sec) or massage (10 strokes in 20 sec from the wrist to the cubital fossa) under tourniquet inflation on the upper arm. Venous palpation was assessed using the venous palpation score (0-6, with 0 being impalpable). Three venous factors-venous depth, cross-sectional area, and elevation-were also measured using ultrasonography. The venous palpation score increased significantly by tapping but not by massage. Moreover, all 3 venous measurements changed significantly by tapping, while only the depth decreased significantly by massage. The three venous measurements correlated significantly with the venous palpation score, indicating that they are useful objective indicators for evaluating vasodilation. We suggest that tapping is an effective vasodilation technique.

  1. Hepatic venous connection to a persistent inferior caval vein in left isomerism.

    PubMed

    Guenthard, J; Carvalho, J S; Anderson, R H; Rigby, M L

    1990-09-01

    In 22 cases of left atrial isomerism studied at the Brompton Hospital, four cases were found to have an unusual arrangement of the abdominal vessels. There was persistence of an inferior caval vein, partially anomalous hepatic venous connection and additional continuation of part of the venous return from the lower body through the azygos venous system. This venous pattern had surgical implications in our index case, since redirection of the inferior caval venous return was necessary.

  2. Multidetector CT of blunt traumatic venous injuries in the chest, abdomen, and pelvis.

    PubMed

    Holly, Brian P; Steenburg, Scott D

    2011-01-01

    Venous injuries as a result of blunt trauma are rare. Even though current protocols for multidetector computed tomography (CT) of patients with trauma are designed to evaluate primarily the solid organs and arteries, blunt venous injuries may nevertheless be identified, or at least suspected, on the basis of the multidetector CT findings. Venous injuries are associated with high morbidity and mortality rates. Diagnosis of a possible venous injury is crucial because the physical findings of a venous injury are nonspecific and may be absent. This article aims to make the radiologist aware of various venous injuries caused by blunt trauma and to provide helpful hints to aid in the identification of venous injuries. Multidetector CT technology, in combination with interactive manipulation of the raw dataset, can be useful in the creation of multiplanar reconstructed images and in the identification of a venous injury caused by blunt trauma. Familiarity with direct and indirect signs of venous injuries, as well as with examples of blunt traumatic venous injuries in the chest, abdomen, and pelvis, will help in the diagnosis of these injuries.

  3. Microfabricated triggered vacuum switch

    DOEpatents

    Roesler, Alexander W [Tijeras, NM; Schare, Joshua M [Albuquerque, NM; Bunch, Kyle [Albuquerque, NM

    2010-05-11

    A microfabricated vacuum switch is disclosed which includes a substrate upon which an anode, cathode and trigger electrode are located. A cover is sealed over the substrate under vacuum to complete the vacuum switch. In some embodiments of the present invention, a metal cover can be used in place of the trigger electrode on the substrate. Materials used for the vacuum switch are compatible with high vacuum, relatively high temperature processing. These materials include molybdenum, niobium, copper, tungsten, aluminum and alloys thereof for the anode and cathode. Carbon in the form of graphitic carbon, a diamond-like material, or carbon nanotubes can be used in the trigger electrode. Channels can be optionally formed in the substrate to mitigate against surface breakdown.

  4. Venous and Arterial Thromboses: Two Sides of the Same Coin?

    PubMed

    Lippi, Giuseppe; Favaloro, Emmanuel J

    2018-04-01

    Arterial and venous thromboses are sustained by development of intraluminal thrombi, respectively, within the venous and arterial systems. The composition and structure of arterial and venous thrombi have been historically considered as being very different. Arterial thrombi (conventionally defined as "white") have been traditionally proposed to be composed mainly of fibrin and platelet aggregates, whilst venous thrombi (conventionally defined as "red") have been proposed as mostly being enriched in fibrin and erythrocytes. This archaic dichotomy seems ever more questionable, since it barely reflects the pathophysiology of thrombus formation in vivo. Both types of thrombi are actually composed of a complex fibrin network but, importantly, also contain essentially the same blood-borne cells (i.e., red blood cells, leukocytes, and platelets), and it is only the relative content of these individual elements that differ between venous and arterial clots or, otherwise, between thrombi generated under different conditions of blood flow and shear stress. Convincing evidence now suggests that either white or red intracoronary thrombi may be present in patients with myocardial infarction and, even more importantly, red thrombi may be more prone to distal embolization during percutaneous coronary intervention than those with lower content of erythrocytes. Conversely, it is now accepted that components traditionally considered to be involved "only" in arterial thrombosis are also represented in venous thrombosis. Thus, platelets comprise important components of venous clots, although they may be present in lower amounts here than in arterial thrombi, and von Willebrand factor is also represented in both arterial and venous thrombi. Of importance, such evidence thus supports the concept that adjunctive treatment normally associated to prevention of arterial thrombosis (e.g., aspirin) may have a role also in prevention and treatment of venous thrombosis. Thieme Medical

  5. Influence of Gap Distance on Vacuum Arc Characteristics of Cup Type AMF Electrode in Vacuum Interrupters

    NASA Astrophysics Data System (ADS)

    Cheng, Shaoyong; Xiu, Shixin; Wang, Jimei; Shen, Zhengchao

    2006-11-01

    The greenhouse effect of SF6 is a great concern today. The development of high voltage vacuum circuit breakers becomes more important. The vacuum circuit breaker has minimum pollution to the environment. The vacuum interrupter is the key part of a vacuum circuit breaker. The interrupting characteristics in vacuum and arc-controlling technique are the main problems to be solved for a longer gap distance in developing high voltage vacuum interrupters. To understand the vacuum arc characteristics and provide effective technique to control vacuum arc in a long gap distance, the arc mode transition of a cup-type axial magnetic field electrode is observed by a high-speed charge coupled device (CCD) video camera under different gap distances while the arc voltage and arc current are recorded. The controlling ability of the axial magnetic field on vacuum arc obviously decreases when the gap distance is longer than 40 mm. The noise components and mean value of the arc voltage significantly increase. The effective method for controlling the vacuum arc characteristics is provided by long gap distances based on the test results. The test results can be used as a reference to develop high voltage and large capacity vacuum interrupters.

  6. Traditional Foley drainage systems--do they drain the bladder?

    PubMed

    Garcia, Maurice M; Gulati, Shelly; Liepmann, Dorian; Stackhouse, G Bennett; Greene, Kirsten; Stoller, Marshall L

    2007-01-01

    Foley catheters are assumed to drain the bladder to completion. Drainage characteristics of Foley catheter systems are poorly understood. To investigate unrecognized retained urine with Foley catheter drainage systems, bladder volumes of hospitalized patients were measured with bladder scan ultrasound volumetrics. Additionally, an in vitro bench top mock bladder and urinary catheter system was developed to understand the etiology of such residual volumes. A novel drainage tube design that optimizes indwelling catheter drainage was also designed. Bedside bladder ultrasound volumetric studies were performed on patients hospitalized in ward and intensive care unit. If residual urine was identified the drainage tubing was manipulated to facilitate drainage. An ex vivo bladder-urinary catheter model was designed to measure flow rates and pressures within the drainage tubing of a traditional and a novel drainage tube system. A total of 75 patients in the intensive care unit underwent bladder ultrasound volumetrics. Mean residual volume was 96 ml (range 4 to 290). In 75 patients on the hospital ward mean residual volume was 136 ml (range 22 to 647). In the experimental model we found that for every 1 cm in curl height, obstruction pressure increased by 1 cm H2O within the artificial bladder. In contrast, the novel spiral-shaped drainage tube demonstrated rapid (0.5 cc per second), continuous and complete (100%) reservoir drainage in all trials. Traditional Foley catheter drainage systems evacuate the bladder suboptimally. Outflow obstruction is caused by air-locks that develop within curled redundant drainage tubing segments. The novel drainage tubing design eliminates gravity dependent curls and associated air-locks, optimizes flow, and minimizes residual bladder urine.

  7. [Venous tone of the limbs. Methods and comparison of 2 areas].

    PubMed

    Journo, H; London, G; Pannier, B; Safar, M

    1989-07-01

    The limb venous tone, index of local venous compliance, was studied with mercury strain gauge plethysmography on 28 male normal subjects (40 +/- 17 years, +/- SD) simultaneously on upper and lower limbs. Measurements were done after 20 mn rest in supine position. Venous tone (VT) equals the slope of the pressure-volume curve established by simultaneous recording of the forearm and calf relative volumes for successive steps of pressure lower than or equal to 30 mmHg. Limb venous capacitance was expressed by means of the maximal limb relative volume (V30) reached for a pressure of 30 mmHg applied through cuffs in standardized conditions. The upper limb venous tone was greater than the lower limb venous tone: 24.3 +/- 8.2 mmHg/ml/100 vs 17.5 +/- 7.9 mmHg/ml/100, p = 0.001. V30 was greater in lower limb than in upper limb: 1.5 +/- 0.5 ml/100 vs 1.1 +/- 0.4 ml/100, p = 0.001. In conclusion, it appears that upper and lower limbs venous distensibility and capacitance are different. They are greater in the lower limb in baseline conditions. Thus simultaneous studies of both these limb venous systems seems important for physiological experiments because of their baseline differences.

  8. Risk factors associated with PICC-related upper extremity venous thrombosis in cancer patients.

    PubMed

    Yi, Xiao-lei; Chen, Jie; Li, Jia; Feng, Liang; Wang, Yan; Zhu, Jia-An; Shen, E; Hu, Bing

    2014-03-01

    To investigate the incidence and risk factors for peripherally inserted central venous catheters-related upper extremity venous thrombosis in patients with cancer. With the widespread use of peripherally inserted central venous catheters, peripherally inserted central venous catheters-related upper extremity venous thrombosis in patients with cancer leads to increasing morbidity and mortality. It is very important to further explore the incidence and risk factors for peripherally inserted central venous catheters-related venous thrombosis. Consecutive patients with cancer who were scheduled to receive peripherally inserted central venous catheters, between September 2009 and May 2012, were prospectively studied in our centre. They were investigated for venous thrombosis by Doppler sonography three times a day within 30 days after catheter insertion. Univariable and multivariable logistic regressions' analyses were performed to identify the risk factors for peripherally inserted central venous catheters-related thrombosis. A total of 89 patients with cancer were studied in our research. Of these, 81 patients were followed up within one month. The mean interval between catheter insertion and the onset of thrombosis was 12.45 ± 6.17 days. The multivariable analyses showed that chemotherapy history, less activities and diabetes were the key risk factors for thrombosis. Peripherally inserted central venous catheters-related upper extremity venous thrombosis had high incidence rate, and most cases had no significant symptoms. The history of chemotherapy, less activities and diabetes were found to be the key risk factors. It should be routinely scanned in high-risk patients every 3-5 days after catheter insertion, which would then find blood clots in time and reduce the incidence of pulmonary embolism. Risk factors associated with peripherally inserted central venous catheters-related upper extremity venous thrombosis are of critical importance in improving the quality

  9. A comparative study of treatments for chronic subdural hematoma: burr hole drainage versus burr hole drainage with irrigation.

    PubMed

    Ishibashi, Akira; Yokokura, Yoshitake; Adachi, Hisashi

    2011-01-01

    Although chronic subdural hematoma (CSDH) is one of the most common entities encountered in neurosurgical practice, optimal surgical treatment for CSDH remains controversial. This study retrospectively compared results for CSDH between burr hole drainage alone and burr hole drainage with irrigation. Ninety-two patients with CSDH underwent surgery at our institution from January 1998 through December 2009. Fifty-eight patients received burr hole drainage alone (Group A), while 34 patients were treated using burr hole drainage with irrigation (Group B). Outcomes, recurrence rates, and death rates for the two groups were analyzed. Age, sex ratio, consciousness level on admission, radiodensity of hematoma on computed tomography before surgery, and duration of hospitalization were nearly the same in both groups. No significant differences were seen in good outcomes or death rates between groups, but poor outcomes were significantly more frequent in Group A (p=0.009). The recurrence rate was higher in Group A compared to Group B (10.3% vs. 2.9%). The authors used logistic regression analysis to identify factors associated with the outcome of CSDH, and found that duration of hospital stay, anti-coagulant therapy, presence of dementia and burr hole drainage alone were significantly associated with poor outcome of CSDH. These results indicate that burr hole drainage with irrigation has a significantly stronger association with good outcomes compared to drainage alone, and could be a reliable and effective operative method for the treatment of CSDH with a lower recurrence rate.

  10. Computational modeling of venous sinus stenosis in idiopathic intracranial hypertension

    PubMed Central

    Levitt, Michael R; McGah, Patrick M; Moon, Karam; Albuquerque, Felipe C; McDougall, Cameron G; Kalani, M Yashar S; Kim, Louis J; Aliseda, Alberto

    2016-01-01

    Background and Purpose Idiopathic intracranial hypertension has been associated with dural venous sinus stenosis in some patients, but the hemodynamic environment of the dural venous sinuses has not been quantitatively described. Here, we present the first such computational fluid dynamics model using patient-specific blood pressure measurements. Materials and Methods Six patients with idiopathic intracranial hypertension and at least one stenosis or atresia at the transverse-sigmoid sinus junction underwent MRV followed by cerebral venography and manometry throughout the dural venous sinuses. Patient-specific computational fluid dynamics models were created using MRV anatomy, with venous pressure measurements as boundary conditions. Blood flow and wall shear stress were calculated for each patient. Results Computational models of dural venous sinuses were successfully reconstructed in all six patients with patient-specific boundary conditions. Three patients demonstrated a pathologic pressure gradient (≥ 8 mm Hg) across four dural venous sinus stenoses. Small sample size precludes statistical comparisons, but average overall flow throughout the dural venous sinuses of patients with pathologic pressure gradients was higher than in those without (1041.00 ± 506.52 vs. 358.00 ± 190.95 mL/min). Wall shear stress was also higher across stenoses in patients with pathologic pressure gradients (37.66 ± 48.39 vs 7.02 ± 13.60 Pa). Conclusion The hemodynamic environment of the dural venous sinuses can be computationally modeled using patient-specific anatomy and physiological measurements in patients with idiopathic intracranial hypertension. There was substantially higher blood flow and wall shear stress in patients with pathological pressure gradients. PMID:27197986

  11. The clinical anatomy of congenital portosystemic venous shunts.

    PubMed

    Stringer, Mark D

    2008-03-01

    Congenital portosystemic venous shunts are rare. Their gross anatomy has not been well defined. Four different varieties of congenital portosystemic venous shunts are described in six children seen during a 10-year period, focusing on the anatomy of the shunt as determined by imaging studies and surgery. A detailed review of the literature indicates that congenital portosystemic venous shunts are best classified as: extrahepatic or intrahepatic. Extrahepatic shunts may be further subdivided into portocaval shunts (type 1 end-to-side and type 2 side-to-side) and others. Intrahepatic shunts are due to an abnormal intrahepatic connection between the portal vein and hepatic vein/inferior vena cava or a persistent patent ductus venosus. Additional congenital anomalies, particularly cardiac malformations, may be associated with any type. Some congenital intrahepatic portosystemic venous shunts close spontaneously in infancy; all other congenital portosystemic venous shunts tend to remain patent. To a variable extent, depending largely on the volume and duration of the shunt, affected individuals are at risk of developing hepatic encephalopathy and/or an intrahepatic tumor. The key to understanding the pathogenesis of these shunts lies in the normal developmental mechanisms underlying the formation of the portal vein and inferior vena cava in the embryo. Copyright 2008 Wiley-Liss, Inc.

  12. Characterization of asphalt drainage course layers.

    DOT National Transportation Integrated Search

    2010-08-01

    Asphalt Drainage Courses (ADCs) have generally been required under all four-lane flexible : pavements in Mississippi. Asphalt drainage courses are designed in Mississippi using No. 57 limestone, : sandstone or granite combined with 2.5 percent asphal...

  13. Endoscope-Assisted Keyhole Technique for Hypertensive Cerebral Hemorrhage in Elderly Patients: A Randomized Controlled Study in 184 Patients.

    PubMed

    Feng, Yi; He, Jianqing; Liu, Bin; Yang, Likun; Wang, Yuhai

    2016-01-01

    Hypertensive cerebral hemorrhage (HCH) is a potentially life-threatening cerebrovascular disease with high mortality. In case of a massive hematoma, surgical drainage is a crucial treatment. The aim of the present study was to assess the efficacy of the endoscope-assisted keyhole technique in elderly patients with intracerebral hematoma who needed a flap craniotomy as traditional treatment. One hundred-eighty-four elderly patients with HCH, who had craniotomy indications after conservative treatment for 6-24 hours after onset, were randomly divided into two groups. In the craniotomy group, traditional hematoma drainage was performed. In the keyhole group, an endoscope-assisted keyhole technique was used. Anesthesia time, blood loss, hematoma drainage rate, and complications were compared. The clinical primary outcome was the six-month efficacy rate (defined by the activities of daily living (ADL) score). Anesthesia time was longer in the craniotomy group (3.43 ± 0.65 vs. 1.53 ± 0.52 h, P < 0.01), and blood losses were more important (256 ± 129 vs. 96 ± 39 ml P < 0.01). There was no difference in hematoma drainage rate between the two groups (77.25 ± 13.44 vs. 83.52 ± 27.51% P > 0.05). Complications, including tracheotomy (P < 0.01), pulmonary infection (P < 0.01) and hypoproteinemia (P < 0.05) were more frequent in the craniotomy group. There was no difference in the occurrence of other complications, including revision surgery digestive tract ulcer and epilepsy. Proportion of patients with good prognosis (ADL I-III) was larger in the keyhole group (P < 0.05). In elderly HCH patients with an indication for hematoma drainage, better outcomes were achieved using an endoscope-assisted keyhole technique.

  14. Interdisciplinary consensus on the uses and technique of MR-guided vacuum-assisted breast biopsy (VAB): results of a European consensus meeting.

    PubMed

    Heywang-Köbrunner, Sylvia H; Sinnatamby, Ruchi; Lebeau, Annette; Lebrecht, Antje; Britton, Peter D; Schreer, Ingrid

    2009-11-01

    Quality assurance of MR-guided vacuum-assisted breast biopsy (VAB). A consensus was achieved based on the existing literature and experience of an interdisciplinary group comprising European specialists in breast imaging and VAB. Full imaging work-up must be completed according to existing standards before an indication for MR-guided VAB is established. The procedure should be reserved for lesions demonstrable by MRI alone. Acquisition of >24 cores (11-Gauge) should be routinely attempted, with the intention of sufficiently removing small lesions for accurate diagnosis. Following biopsy the patient should be re-imaged to demonstrate the biopsy site and its proximity to the lesion and hence the likely accuracy of the sampling. All patients should be discussed in a regular interdisciplinary conference and a documented consensus reached regarding patient management. Regular audit and review of all MR-guided VAB results and subsequent follow-up are recommended. This consensus includes protocols for the indication, performance parameters, interdisciplinary interpretation therapeutic recommendation, documentation and follow-up of MR-guided VAB. It does not replace official recommendations for percutaneous biopsy.

  15. Arterial versus venous lactate: a measure of sepsis in children.

    PubMed

    Samaraweera, Sahan Asela; Gibbons, Berwyck; Gour, Anami; Sedgwick, Philip

    2017-08-01

    This study assessed the agreement between arterial and venous blood lactate and pH levels in children with sepsis. This retrospective, three-year study involved 60 PICU patients, with data collected from electronic or paper patient records. The inclusion criteria comprised of children (≤17 years old) with sepsis and those who had a venous blood gas taken first with an arterial blood gas taken after within one hour. The lactate and pH values measured through each method were analysed. There is close agreement between venous and arterial lactate up to 2 mmol/L. As this value increases, this agreement becomes poor. The limits of agreement (LOA) are too large (±1.90 mmol/L) to allow venous and arterial lactate to be used interchangeably. The mean difference and LOA between both methods would be much smaller if derived using lactate values under 2.0 mmol/L. There is close agreement between arterial and venous pH (MD = -0.056, LOA ± 0.121). However, due to extreme variations in pH readings during sepsis, pH alone is an inadequate marker. A venous lactate ≤2 mmol/L can be used as a surrogate for arterial lactate during early management of sepsis in children. However, if the value exceeds 2 mmol/L, an arterial sample must confirm the venous result. What is known: • In children with septic shock, a blood gas is an important test to show the presence of acidosis and high lactic acid. Hyperlactataemia on admission is an early predictor of outcome and is associated with a greater mortality risk. • An arterial sample is the standard for lactate measurement, however getting a sample may be challenging in the emergency department or a general paediatric ward. Venous samples are quicker and easier to obtain. Adult studies generally advise caution in replacing venous lactate values for the arterial standard, whilst paediatric studies are limited in this area. What is new: • This is the first study assessing the agreement between arterial and peripheral venous

  16. DKA, CVL and DVT. Increased risk of deep venous thrombosis in children with diabetic ketoacidosis and femoral central venous lines.

    PubMed

    Davis, J; Surendran, T; Thompson, S; Corkey, C

    2007-01-01

    Incidence of type 1 diabetes mellitus is continuing to rise in children. The presentation of diabetic ketoacidosis (DKA) in children with newly diagnosed diabetes is significantly higher in those less than 5 years old. Critically ill patients admitted to Paediatric Intensive Care Units (PICU), would have a central venous line (CVL) inserted as part of their ongoing management. There are associations linking with the development of deep venous thrombosis (DVT) in DKA/CVL patients. An 18-month-old boy presented with a short history of polydypsia, polyuria and weight loss. The initial blood sugar was 27.0 mmol/L and a venous blood gas showed severe metabolic acidosis. He was diagnosed and treated for DKA. He was transferred to the regional PICU for further management. There, a central venous line (CVL) was inserted in his left femoral vein. This was removed on Day 4. Subsequently, he developed a swelling on his left leg, with significant discrepancy in leg circumference. Doppler ultrasound confirmed a deep venous thrombosis. Conclusion Diabetes has a propensity for hypercoagulability and DKA promotes a prothrombotic state. Retrospective studies have shown younger patients with DKA and a femoral CVL are at higher risk of developing DVT. A central femoral line should avoided in such patients. DVT prophylaxis and Doppler follow up should also be considered.

  17. Venous return curves obtained from graded series of valsalva maneuvers

    NASA Technical Reports Server (NTRS)

    Mastenbrook, S. M., Jr.

    1974-01-01

    The effects were studied of a graded series of valsalva-like maneuvers on the venous return, which was measured transcutaneously in the jugular vein of an anesthetized dog, with the animal serving as its own control. At each of five different levels of central venous pressure, the airway pressure which just stopped venous return during each series of maneuvers was determined. It was found that this end-point airway pressure is not a good estimator of the animal's resting central venous pressure prior to the simulated valsalva maneuver. It was further found that the measured change in right atrial pressure during a valsalva maneuver is less than the change in airway pressure during the same maneuver, instead of being equal, as had been expected. Relative venous return curves were constructed from the data obtained during the graded series of valsalva maneuvers.

  18. A portable thoracic closed drainage instrument for hemopneumothorax.

    PubMed

    Tang, Hua; Pan, Tiewen; Qin, Xiong; Xue, Lei; Wu, Bin; Zhao, Xuewei; Sun, Guangyuan; Yuan, Xinyu; Xu, Zhifei

    2012-03-01

    Hemopneumothorax is a common sequelae of traumatic thoracic injury. The most effective treatment of this condition is thoracic drainage. Despite the common occurrence of this condition, available instruments are difficult to use emergently, particularly when large amounts of patients need to be drained. In the present experiment, a newly designed chest tube and thoracic closed drainage package is described and preliminarily evaluated with the goal to improve the treatment of traumatic hemopneumothorax. Twenty canines were divided into two groups. In one group, the newly designed thoracic closed drainage package was used, whereas in the other group a currently available chest tube and bottle were used. Drainage test, ultrasound examination, flushing test, and tension test were performed to evaluate the effectiveness of the drainage package. We found that the newly-designed drainage tube is as effective as the common tube when evaluated using all of the chosen methods. In addition, the package is very lightweight and portable. The newly-designed thoracic drainage package is very effective in the emergency treatment of thoracic trauma and may be more suitable for the emergency treatment of hemopneumothorax.

  19. Evaluation of treatment with carboxymethylcellulose on chronic venous ulcers*

    PubMed Central

    Januário, Virginia; de Ávila, Dione Augusto; Penetra, Maria Alice; Sampaio, Ana Luisa Bittencourt; Noronha Neta, Maria Isabel; Cassia, Flavia de Freire; Carneiro, Sueli

    2016-01-01

    BACKGROUND: Among the chronic leg ulcers, venous ulcers are the most common and constitute a major burden to public health. Despite all technology available, some patients do not respond to established treatments. In our study, carboxymethylcellulose was tested in the treatment of refractory chronic venous ulcers. OBJECTIVE: To evaluate the efficacy of carboxymethylcellulose 20% on the healing of chronic venous ulcers refractory to conventional treatments. METHODS: This is an analytical, pre-experimental study. Thirty patients were included with refractory venous ulcers, and applied dressings with carboxymethylcellulose 20% for 20 weeks. The analysis was based on measurement of the area of ulcers, performed at the first visit and after the end of the treatment. RESULTS: There was a reduction of 3.9 cm2 of lesion area (p=0.0001), corresponding to 38.8% (p=0.0001). There was no interruption of treatment and no increase in lesion area in any patient. CONCLUSIONS: Carboxymethylcellulose 20% represents a low cost and effective therapeutic alternative for the treatment of refractory chronic venous ulcers. However, controlled studies are necessary to prove its efficacy. PMID:26982773

  20. Acquired factor V inhibitor in a patient receiving venous-venous extracorporeal membrane oxygenation for Legionella pneumonia.

    PubMed

    Leung, Anne K H; Ng, George W Y; Sin, K C; Au, S Y; Lai, K Y; Lee, K L; Law, K I

    2015-04-01

    We report a rare complication of factor V deficiency in a patient having Legionella pneumonia. This patient also had other complications like severe acute respiratory distress syndrome, acute kidney injury, and septic shock that required venous-venous extracorporeal membrane oxygenation support. This is the first reported case of acquired factor V deficiency in a patient receiving extracorporeal membrane oxygenation for Legionella pneumonia. With the combined use of intravenous immunoglobulin, rituximab and plasma exchange, we achieved rapid clearance of the factor V inhibitor within 1 week so as to allow safe decannulation of extracorporeal membrane oxygenation.

  1. 21 CFR 870.1140 - Venous blood pressure manometer.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Venous blood pressure manometer. 870.1140 Section 870.1140 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES CARDIOVASCULAR DEVICES Cardiovascular Diagnostic Devices § 870.1140 Venous blood...

  2. Significance of pathological positive superior mesenteric/portal venous invasion in pancreatic cancer.

    PubMed

    Tewari, Mallika

    2016-12-01

    Pancreaticoduodenectomy with superior mesenteric/portal venous resection for pancreatic ductal adenocarcinoma (PDAC) is frequently performed with no added morbidity or mortality in case of tumor abutment to the superior mesenteric or portal vein so as to obtain a margin negative resection. True histopathological portal vein invasion is found only in a small subset of such patients. The aim of this review aimed to discuss the significance of histopathological venous invasion in PDAC. For this review available data was searched from PubMed and analyzed. No randomized trials have been published on this topic. Existing data on prognostic factors in histopathological venous invasion by PDAC are limited and recent studies indicate worse survival in this subgroup of patients. In addition, venous invasion in PDAC has been associated with large tumors, involved lymph nodes, perineural invasion and R1 resection. The survival of patients with portal venous resection but without histologic venous invasion is reportedly better than those with histopathological venous invasion; though conflicting studies do exist on the subject. Some studies also relate the depth of venous invasion to prognosis after surgical resection of PDAC. Frank/'histopathological' invasion of superior mesenteric/portal venous and R1 resection indicate a very poor survival. Such patients may be given the opportunity of benefit of neoadjuvant treatment.

  3. Right atrial pressure: determinant or result of change in venous return?

    PubMed

    Bendjelid, Karim

    2005-11-01

    According to the concept of Guyton, cardiac output is largely controlled by venous return, which is determined by the difference between mean systemic venous pressure and right atrial pressure. In the analysis of the venous return curve, other authors have suggested that right atrial pressure is the dependent variable and venous return is the independent variable (right atrial pressure decreased because cardiac output increased). The present report analyzes this historical debate, which has already lasted > 50 years.

  4. Consideration of Preventing Local Venous Pain by Dacarbazine.

    PubMed

    Ohtsubo, Tatsuya; Tsuji, Takumi; Umeyama, Takayo; Sudou, Miho; Komesu, Kana; Matsumoto, Minako; Yoshida, Yuya; Banno, Rie; Tomogane, Kanji; Fujita, Atsuo; Kohno, Takeyuki; Mikami, Tadashi

    2017-01-01

    Local venous pain caused by dacarbazine (DTIC) injection is due to its photodegradation product 5-diazoimidazole-4-carboxamide (Diazo-IC). The production of Diazo-IC can be decreased by protecting the drug from light. Furthermore, the production of Diazo-IC reportedly increases with time; however, there are no studies reporting the association between the injection preparation time and local venous pain caused by the DTIC injection. We evaluated the efficacy of the following: (1) method used to shorten the injection preparation time and (2) method used to change the diluting solution for DTIC. We found that shortening the injection preparation time tended to decrease the local venous pain expression due to DTIC, and Veen F decreased the production of Diazo-IC compared with the normal saline and 5% glucose solution. These results indicate that shortening the injection preparation time may be effective in preventing the local venous pain caused by the DTIC injection; moreover, using Veen F for DTIC may also reduce the pain.

  5. Current challenges in diagnostic imaging of venous thromboembolism.

    PubMed

    Huisman, Menno V; Klok, Frederikus A

    2015-01-01

    Because the clinical diagnosis of deep-vein thrombosis and pulmonary embolism is nonspecific, integrated diagnostic approaches for patients with suspected venous thromboembolism have been developed over the years, involving both non-invasive bedside tools (clinical decision rules and D-dimer blood tests) for patients with low pretest probability and diagnostic techniques (compression ultrasound for deep-vein thrombosis and computed tomography pulmonary angiography for pulmonary embolism) for those with a high pretest probability. This combination has led to standardized diagnostic algorithms with proven safety for excluding venous thrombotic disease. At the same time, it has become apparent that, as a result of the natural history of venous thrombosis, there are special patient populations in which the current standard diagnostic algorithms are not sufficient. In this review, we present 3 evidence-based patient cases to underline recent developments in the imaging diagnosis of venous thromboembolism. © 2015 by The American Society of Hematology. All rights reserved.

  6. Neonatal venous cerebral hemorrhage. Report of two cases.

    PubMed

    Misra, Sanjay N; Misra, Ashish K

    2003-10-15

    Intracranial pathological changes can occur as a result of impaired craniocervical venous return. Thrombosis of central venous access catheters was demonstrated in two neonates born at 38 and 27 weeks' gestation. Neither infant developed hemorrhage of prematurity as confirmed on cranial ultrasonography. Clinical evidence of vena cava thrombosis and associated spontaneous intraventricular hemorrhage developed on Day 24 and 36, respectively, and these findings were confirmed on imaging studies. In one infant the hemorrhage was accompanied by communicating hydrocephalus. The cause of the intracranial disease was attributable to the retrograde cerebral venous congestion. This, together with the primitive venous bed developing in the periventricular region, was associated with the spontaneous hemorrhage in the region of the foramen of Monro. To the authors' knowledge, this is the first report in the English-language literature of spontaneous neonatal intracerebral hemorrhage, due to thrombosis of the superior or inferior vena cava. The natural history of this condition is resolution without sequelae after appropriate therapeutic intervention for the vena cava thrombosis.

  7. Decreased brain venous vasculature visibility on susceptibility-weighted imaging venography in patients with multiple sclerosis is related to chronic cerebrospinal venous insufficiency

    PubMed Central

    2011-01-01

    Background The potential pathogenesis between the presence and severity of chronic cerebrospinal venous insufficiency (CCSVI) and its relation to clinical and imaging outcomes in brain parenchyma of multiple sclerosis (MS) patients has not yet been elucidated. The aim of the study was to investigate the relationship between CCSVI, and altered brain parenchyma venous vasculature visibility (VVV) on susceptibility-weighted imaging (SWI) in patients with MS and in sex- and age-matched healthy controls (HC). Methods 59 MS patients, 41 relapsing-remitting and 18 secondary-progressive, and 33 HC were imaged on a 3T GE scanner using pre- and post-contrast SWI venography. The presence and severity of CCSVI was determined using extra-cranial and trans-cranial Doppler criteria. Apparent total venous volume (ATVV), venous intracranial fraction (VIF) and average distance-from-vein (DFV) were calculated for various vein mean diameter categories: < .3 mm, .3-.6 mm, .6-.9 mm and > .9 mm. Results CCSVI criteria were fulfilled in 79.7% of MS patients and 18.2% of HC (p < .0001). Patients with MS showed decreased overall ATVV, ATVV of veins with a diameter < .3 mm, and increased DFV compared to HC (all p < .0001). Subjects diagnosed with CCSVI had significantly increased DFV (p < .0001), decreased overall ATVV and ATVV of veins with a diameter < .3 mm (p < .003) compared to subjects without CCSVI. The severity of CCSVI was significantly related to decreased VVV in MS (p < .0001) on pre- and post-contrast SWI, but not in HC. Conclusions MS patients with higher number of venous stenoses, indicative of CCSVI severity, showed significantly decreased venous vasculature in the brain parenchyma. The pathogenesis of these findings has to be further investigated, but they suggest that reduced metabolism and morphological changes of venous vasculature may be taking place in patients with MS. PMID:22011402

  8. Validation of Risk Assessment Models of Venous Thromboembolism in Hospitalized Medical Patients.

    PubMed

    Greene, M Todd; Spyropoulos, Alex C; Chopra, Vineet; Grant, Paul J; Kaatz, Scott; Bernstein, Steven J; Flanders, Scott A

    2016-09-01

    Patients hospitalized for acute medical illness are at increased risk for venous thromboembolism. Although risk assessment is recommended and several at-admission risk assessment models have been developed, these have not been adequately derived or externally validated. Therefore, an optimal approach to evaluate venous thromboembolism risk in medical patients is not known. We conducted an external validation study of existing venous thromboembolism risk assessment models using data collected on 63,548 hospitalized medical patients as part of the Michigan Hospital Medicine Safety (HMS) Consortium. For each patient, cumulative venous thromboembolism risk scores and risk categories were calculated. Cox regression models were used to quantify the association between venous thromboembolism events and assigned risk categories. Model discrimination was assessed using Harrell's C-index. Venous thromboembolism incidence in hospitalized medical patients is low (1%). Although existing risk assessment models demonstrate good calibration (hazard ratios for "at-risk" range 2.97-3.59), model discrimination is generally poor for all risk assessment models (C-index range 0.58-0.64). The performance of several existing risk assessment models for predicting venous thromboembolism among acutely ill, hospitalized medical patients at admission is limited. Given the low venous thromboembolism incidence in this nonsurgical patient population, careful consideration of how best to utilize existing venous thromboembolism risk assessment models is necessary, and further development and validation of novel venous thromboembolism risk assessment models for this patient population may be warranted. Published by Elsevier Inc.

  9. Effect of vacuum-assisted closure combined with open bone grafting to promote rabbit bone graft vascularization.

    PubMed

    Hu, Chao; Zhang, Taogen; Ren, Bin; Deng, Zhouming; Cai, Lin; Lei, Jun; Ping, Ansong

    2015-04-27

    Patients with composite bone non-union and soft tissue defects are difficult to treat. Vacuum-assisted closure (VAC) combined with open bone grafting is one of the most effective treatments at present. The aim of the present study was to preliminarily investigate the effect and mechanism of VAC combined with open bone grafting to promote rabbit bone graft vascularization, and to propose a theoretical basis for clinical work. Twenty-four New Zealand white rabbits were randomly divided into an experimental and a control group. Allogeneic bones were grafted and banded with the proximal femur with a suture. The experimental group had VAC whereas the control group had normal wound closure. The bone vascularization rate was compared based on X-ray imaging, fluorescent bone labeling (labeled tetracycline hydrochloride and calcein), calcium content in the callus, and expression of fibroblast growth factor-2 (FGF-2) in bone allografts by Western blot analysis at the 4th, 8th, and 12th week after surgery. At the 4th, 8th, and 12th week after surgery, the results of the tests demonstrated that the callus was larger, contained more calcium (p<0.05), and expressed FGF-2 at higher levels (p<0.05) in the experimental group than in the control group. Fluorescent bone labeling showed the distance between the two fluorescent ribbons was significantly shorter in the control group than in the experimental group at the 8th and 12th week after surgery. VAC combined with open bone grafting promoted rabbit bone graft vascularization.

  10. Vacuum probe surface sampler

    NASA Technical Reports Server (NTRS)

    Zahlava, B. A. (Inventor)

    1973-01-01

    A vacuum probe surface sampler is described for rapidly sampling relatively large surface areas which possess relatively light loading densities of micro-organism, drug particles or the like. A vacuum head with a hollow handle connected to a suitable vacuum source is frictionally attached to a cone assembly terminating in a flared tip adapted to be passed over the surface to be sampled. A fine mesh screen carried by the vacuum head provides support for a membrane filter which collects the microorganisms or other particles. The head assembly is easily removed from the cone assembly without contacting the cone assembly with human hands.

  11. Clinical impact of the disposable ventouse iCup® versus a metallic vacuum cup: a multicenter randomized controlled trial.

    PubMed

    Equy, Véronique; David-Tchouda, Sandra; Dreyfus, Michel; Riethmuller, Didier; Vendittelli, Françoise; Cabaud, Victoire; Langer, Bruno; Margier, Jennifer; Bosson, Jean-Luc; Schaal, Jean-Patrick

    2015-12-15

    Assisted vaginal delivery by vacuum extraction is frequent. Metallic resterilizible metallic vacuum cups have been routinely used in France. In the last few years a new disposable semi-soft vacuum extraction cup, the iCup, has been introduced. Our objective was to compare maternal and new-born outcomes between this disposable cup and the commonly used Drapier-Faure metallic cup. This was a multicenter prospective randomized controlled open clinical trial performed in the maternity units of five university hospitals and one community hospital in France from October 2009 to February 2013. We included consecutive eligible women with a singleton gestation of at least 37 weeks who required vacuum assisted delivery. Women were randomized to vacuum extraction using the iCup or usual Drapier-Faure metallic cup. The primary outcome was a composite criterion including both the risk of cup dysfunction and the most frequent maternal and neonatal harms: the use of other instruments after attempted vacuum extraction, caesarean section after attempted vacuum extraction, three detachments of the cup, caput succedaneum, cephalohaematoma, episiotomy and perineal tears. 335 women were randomized to the disposable cup and 333 to extraction using the metallic cup. There was no significant difference between the two groups for the primary outcome. However, failed instrumental delivery was more frequent in the disposable cup group, mainly due to detachment: 35.6 % vs 7.1 %, p < 0.0001. Conversely, perineal tears were more frequent in the metallic cup group, especially third or fourth grade perineal tears: 1.7 % versus 5.0 %, p = 0.003. There were no significant differences between the two groups concerning post-partum haemorrhage, transfer to a neonatal intensive care unit (NICU) or serious adverse events. While the disposable cup had more detachments and extraction failures than the standard metallic cup, this innovative disposable device had the advantage of fewer perineal

  12. Non-surgical biliary drainage - technique, indications and results.

    PubMed

    Riemann, J F; Lux, G; Rösch, W; Beickert-Sterba, A

    1981-07-01

    Nonsurgical biliary drainage offers a therapeutic alternative in the palliation of malignant obstructive jaundice. Two basic approaches are available. The percutaneous transhepatic method can be employed either for external drainage or for the placement of an internal endoprosthesis. In the case of the transduodenal, transpapillary approach, either a pigtail catheter can be placed, after prior papillotomy, or - with or without the need to split the papillar - a nasobiliary drainage tube can be introduced. Successful drainage was achieved in 67 patients. In the majority of cases, external drainage was performed as a palliative measure in inoperable carcinoma of the biliodigestive system. In addition, however, pre-operative temporary drainage was also carried out to reduce the risks of surgery in patients with severe obstructive jaundice. The complication rate was low. Apart from biliary peritonitis, cholangitis and minor bleeds were observed. The rate of failure for technical reasons was a relatively low 10%.

  13. [Venous thrombosis of atypical location in patients with cancer].

    PubMed

    Campos Balea, Begoña; Sáenz de Miera Rodríguez, Andrea; Antolín Novoa, Silvia; Quindós Varela, María; Barón Duarte, Francisco; López López, Rafael

    2015-01-01

    Venous thromboembolism (VTE) is a complication that frequently occurs in patients with neoplastic diseases. Several models have therefore been developed to identify patient subgroups diagnosed with cancer who are at increased risk of developing VTE. The most common forms of thromboembolic episodes are deep vein thrombosis in the lower limbs and pulmonary thromboembolism. However, venous thrombosis is also diagnosed in atypical locations. There are few revisions of unusual cases of venous thrombosis. In most cases, VTE occurs in the upper limbs and in the presence of central venous catheters, pacemakers and defibrillators. We present the case of a patient diagnosed with breast cancer and treated with surgery, chemotherapy and radiation therapy who developed a thrombosis in the upper limbs (brachial and axillary). Copyright © 2015 Elsevier España, S.L.U. All rights reserved.

  14. Non-contact imaging of venous compliance in humans using an RGB camera

    NASA Astrophysics Data System (ADS)

    Nakano, Kazuya; Satoh, Ryota; Hoshi, Akira; Matsuda, Ryohei; Suzuki, Hiroyuki; Nishidate, Izumi

    2015-04-01

    We propose a technique for non-contact imaging of venous compliance that uses the red, green, and blue (RGB) camera. Any change in blood concentration is estimated from an RGB image of the skin, and a regression formula is calculated from that change. Venous compliance is obtained from a differential form of the regression formula. In vivo experiments with human subjects confirmed that the proposed method does differentiate the venous compliances among individuals. In addition, the image of venous compliance is obtained by performing the above procedures for each pixel. Thus, we can measure venous compliance without physical contact with sensors and, from the resulting images, observe the spatial distribution of venous compliance, which correlates with the distribution of veins.

  15. [Prophylaxis of thrombosis induced by chemotherapy or central venous catheters].

    PubMed

    Voog, Eric; Lazard, Eric; Juhel, Laurence

    2007-02-01

    Deep venous thrombosis and pulmonary embolism are well-recognized complications of cancer, especially in patients with a venous access device or receiving chemotherapy. The pathogenic mechanisms of thrombosis in cancer patients involve a complex interaction between the patient's tumor cells and hemostatic system. Chemotherapy and central venous catheters increase the risk of thromboembolism. Prophylactic treatment for these patients remains controversial. We conducted a systematic literature review using the Medline database and abstract books for meetings of the American Society of Clinical Oncology and the American Society of Hematology since 2000. Our search focused on clinical trials of primary prevention of venous catheter-related thrombosis or prevention of chemotherapy-related venous thromboembolism in cancer patients. Ten studies evaluating primary prevention of patients with central catheters were identified, and their results are contradictory. Currently only one study has examined prevention of chemotherapy-related venous thromboembolism, in women with metastatic breast cancer. Its results cannot be extrapolated to other tumors. Systematic prophylaxis cannot yet be recommended. In the near future we must improve our knowledge of the risk factors of these complications. Prophylaxis should be individualized for each patient. New anticoagulant drugs should be tested in cancer patients.

  16. Occult pulmonary embolism: a common occurrence in deep venous thrombosis

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Dorfman, G.S.; Cronan, J.J.; Tupper, T.B.

    1987-02-01

    Ventilation-perfusion scans were used in a prospective study to determine the prevalence of occult pulmonary embolus in proven deep venous thrombosis. Fifty-eight patients without symptoms of pulmonary embolism, but with venographically proven deep venous thrombosis, were subjected to chest radiographs, /sup 99m/Tc macroaggregated-albumin perfusion scans, and /sup 133/Xe ventilation scans. Of the 49 patients with deep venous thrombosis proximal to the calf veins, 17 (35%) had high-probability scans. Of all 58 patients, only 12 (21%) had normal scans. When the study population was compared with a group of 430 patients described in reports of pulmonary perfusion in asymptomatic persons, amore » significantly higher percentage of high-probability scans was found in the study population with deep venous thrombosis. Baseline ventilation-perfusion lung scanning is valuable for patients with proven above-knee deep venous thrombosis.« less

  17. Comparison of work rates, energy expenditure, and perceived exertion during a 1-h vacuuming task with a backpack vacuum cleaner and an upright vacuum cleaner.

    PubMed

    Mengelkoch, Larry J; Clark, Kirby

    2006-03-01

    The purpose of this study was to evaluate two types of industrial vacuum cleaners, in terms of cleaning rates, energy expenditure, and perceived exertion. Twelve industrial cleaners (six males and six females, age 28-39 yr) performed two 1-h vacuuming tasks with an upright vacuum cleaner (UVC) and a backpack vacuum cleaner (BPVC). Measures for oxygen uptake (VO2) and ratings of perceived exertion (RPE) were collected continuously during the 1-h vacuuming tasks. Cleaning rates for the UVC and BPVC were 7.23 and 14.98 m2min(-1), respectively. On a separate day subjects performed a maximal treadmill exercise test to determine their maximal aerobic capacity (peak VO2). Average absolute energy costs (in Metabolic equivalents), relative energy costs of the vacuum task compared to the subjects' maximal aerobic capacity (% peak VO2), and RPE responses for the 1-h vacuuming tasks were similar between vacuum cleaners, but % peak VO2 and RPE values differed between genders. These results indicate that the BPVC was more efficient than the UVC. With the BPVC, experienced workers vacuumed at a cleaning rate 2.07 times greater than the UVC and had similar levels of energy expenditure and perceived effort, compared to the slower cleaning rate with the UVC.

  18. Ultrasound-assisted drug delivery for treatment of venous thrombosis: a case study.

    PubMed

    Marchiondo, Kathleen; Frink, Amber

    2008-01-01

    Ultrasound-assisted drug delivery is a relatively new medical intervention that combines low-intensity ultrasound waves with infusion of a thrombolytic agent directly into a thrombosed vein. Studies have demonstrated that clots are eradicated faster, more completely, and with fewer bleeding events with the use of ultrasound-assisted drug delivery for treatment of deep vein thrombosis compared to that of traditional therapies. Critical care nurses are responsible for preprocedure assessment and teaching and continuous monitoring of the patient during therapy for effectiveness and potential complications. An advantage of this technology from a nursing perspective is the minimal amount of time required for monitoring the drug delivery system, allowing greater focus on patient assessment and care.

  19. Preoperative Evaluation of Collateral Venous Anastomoses in Meningioma Involving Cerebral Venous Sinus by Susceptibility Weighted Imaging

    PubMed Central

    Wang, Qing; He, Jingzhen; Ma, Xiangxing

    2014-01-01

    Abstract Precise preoperative identification of the collateral venous anastomoses is critical for proper surgical management of patients with meningioma involving sinus. This study was to assess the feasibility of susceptibility weighted imaging (SWI) to delineate the collateral venous anastomoses before surgery. Twenty-five patients with meningiomas that were involved in sinuses underwent surgery and the collateral anastomoses were evaluated with SWI and phase-contrast magnetic resonance venography (MRV) before surgery. The results obtained with SWI were compared with those obtained with MRV. Intraoperative findings were used as the gold standard. By surgery, a total of 98 collateral anastomotic veins were identified in the 25 patients. SWI depicted 85 collateral anastomotic veins close to the meningioma with a sensitivity of 87%, whereas MRV showed 57 collateral anastomotic veins with a sensitivity of 58%. The detectability of collateral anastomotic veins in SWI images was superior to MRV. The results suggest that SWI is superior to MRV and could provide more reliable information on the collateral venous anastomoses in patients with meningioma. PMID:25501068

  20. Early thrombus removal strategies for acute deep venous thrombosis: clinical practice guidelines of the Society for Vascular Surgery and the American Venous Forum.

    PubMed

    Meissner, Mark H; Gloviczki, Peter; Comerota, Anthony J; Dalsing, Michael C; Eklof, Bo G; Gillespie, David L; Lohr, Joann M; McLafferty, Robert B; Murad, M Hassan; Padberg, Frank; Pappas, Peter; Raffetto, Joseph D; Wakefield, Thomas W

    2012-05-01

    The anticoagulant treatment of acute deep venous thrombosis (DVT) has been historically directed toward the prevention of recurrent venous thromboembolism. However, such treatment imperfectly protects against late manifestations of the postthrombotic syndrome. By restoring venous patency and preserving valvular function, early thrombus removal strategies can potentially decrease postthrombotic morbidity. A committee of experts in venous disease was charged by the Society for Vascular Surgery and the American Venous Forum to develop evidence-based practice guidelines for early thrombus removal strategies, including catheter-directed pharmacologic thrombolysis, pharmacomechanical thrombolysis, and surgical thrombectomy. Evidence-based recommendations are based on a systematic review and meta-analysis of the relevant literature, supplemented when necessary by less rigorous data. Recommendations are made according to the Grading of Recommendations Assessment, Development and Evaluation (GRADE) methodology, incorporating the strength of the recommendation (strong: 1; weak: 2) and an evaluation of the level of the evidence (A to C). On the basis of the best evidence currently available, we recommend against routine use of the term "proximal venous thrombosis" in favor of more precise characterization of thrombi as involving the iliofemoral or femoropopliteal venous segments (Grade 1A). We further suggest the use of early thrombus removal strategies in ambulatory patients with good functional capacity and a first episode of iliofemoral DVT of <14 days in duration (Grade 2C) and strongly recommend their use in patients with limb-threatening ischemia due to iliofemoral venous outflow obstruction (Grade 1A). We suggest pharmacomechanical strategies over catheter-directed pharmacologic thrombolysis alone if resources are available and that surgical thrombectomy be considered if thrombolytic therapy is contraindicated (Grade 2C). Most data regarding early thrombus removal