Science.gov

Sample records for vaginal tape obturator

  1. Ten-Year Followup after Tension-Free Vaginal Tape-Obturator Procedure for Stress Urinary Incontinence.

    PubMed

    Ulrich, Daniela; Tammaa, Ayman; Hölbfer, Susanne; Trutnovsky, Gerda; Bjelic-Radisic, Vesna; Tamussino, Karl; Aigmüller, Thomas

    2016-10-01

    Suburethral tapes are a standard surgical treatment for stress urinary incontinence. The aim of the study was to evaluate subjective and objective cure rates 10 years after a tension-free vaginal tape-obturator procedure. All 124 patients who underwent the tension-free vaginal tape-obturator procedure at a total of 2 centers in 2004 and 2005 were invited for followup. Objective cure was defined as a negative cough stress test at 300 ml. Subjects completed KHQ (King's Health Questionnaire), IOQ (Incontinence Outcome Questionnaire), FSFI (Female Sexual Function Index Questionnaire) and PGI-I (Patient Global Impression of Improvement). Overall, 55 of 112 women (49%) who were alive were available for clinical examination and 71 (63%) completed the questionnaires. The objective cure rate in the 55 women examined clinically was 69%, 22% were not cured and 9% (5) had undergone reoperation for recurrent or persistent stress urinary incontinence. Treatment was counted as having failed in these 5 women for study purposes. Subjective cure was reported by 45 of 71 women (64%). Three patients (5%) had vaginal tape extrusion at the time of clinical examination. Extrusion in all of them was small and asymptomatic, and did not require treatment for a cumulative extrusion rate of 7%. Six women (9%) had undergone reoperation for tension-free vaginal tape-obturator associated complications and 18 (26%) experienced de novo overactive bladder. Subjective and objective cure rates 10 years after the tension-free vaginal tape-obturator procedure were 69% and 64%, respectively. The vaginal extrusion rate in this study was slightly higher than in other series but major long-term complications appeared to be rare. Copyright © 2016 American Urological Association Education and Research, Inc. Published by Elsevier Inc. All rights reserved.

  2. Randomized clinical trial comparing TVT Secur system and trans vaginal obturator tape for the surgical management of stress urinary incontinence.

    PubMed

    Maslow, Ken; Gupta, Chander; Klippenstein, Peter; Girouard, Lise

    2014-07-01

    This prospective randomized study aimed to compare the safety and efficacy of the TVT-Secur (TVT-S) with the trans vaginal obturator tape (TVT-O) for the treatment of stress urinary incontinence. We set out to enroll 136 patients in our study. 106 patients with stress urinary incontinence were randomized to either the TVT-S (n = 56) or TVT-O (n = 50) procedure. Patients were evaluated postoperatively at 2 months and 1 year. Our primary outcome was objective cure measured by the cough test. Secondary outcomes of subjective symptoms, questionnaires, pain scores, complications, and urodynamic studies were also included. Statistical analysis was by Chi-squared, Kruskal-Wallis, Wilcoxon, and Fisher's exact tests as appropriate. P values of <0.05 were considered significant. Objective cure rates were better for TVT-O compared with TVT-S at 1 year (86 % and 63 % respectively, p = 0.01). Subjective cure rates were 88 % for TVT-O and 63 % for TVT-S. Quality of life scores through questionnaires improved in both groups and were not statistically different. Initial post-operative groin pain was more prevalent in the TVT-O group; however, this resolved quickly with time. TVT-O was superior to TVT-S in the objective cure of stress urinary incontinence at 1-year follow-up.

  3. Trans-obturator vaginal tape (TOT) for female stress incontinence: one year follow-up in 120 patients.

    PubMed

    Roumeguère, Thierry; Quackels, Th; Bollens, R; de Groote, A; Zlotta, A; Bossche, M Vanden; Schulman, C

    2005-11-01

    The aim of this study was to evaluate the effectiveness of a new minimally invasive surgical procedure, the Trans-obturator Vaginal Tape (TOT) in the treatment of female urodynamic stress incontinence (USI) and to analyse functional results and quality of life after one year of follow up. 120 consecutive women with stress urinary incontinence underwent the procedure since February 2002 under general or loco-regional anesthesia. Minimum follow up was one year (range 12-30 months). Mean age was 58 years (range 31-86). 70% of the patients had pure USI. 5 patients were previously operated for USI. In 10 cases, concomitant repair of pelvic floor defects was mandatory. Collection of the data included operative time, pre- and post-operative complications. Patients were post-operatively assessed at one week, one month and one year. A validated urinary incontinence-specific measure of Quality of Life (QoL) questionnaire (Contilife) was sent and completed 12 months after surgery. The mean operative time was 12 min (range 6-30) with a catheterisation time of 0,9 day (range 0-2). No severe bleeding was observed. There were 13 minor lateral tears of the vagina without any sequelae. Three perforations of the urethra and one of the bladder occurred during the learning phase. In two cases a re-intervention was necessary for tape removal when the injury was not recognised during the procedure. Two transient urinary retention needed a supra pubic catheter and tape release. Eleven women presented transient voiding outflow obstruction. After one month, 93% patients were cured with no pad and a negative cough test with a full bladder. Uroflowmetry did not show any significant changes between pre- and post-operative time in all the population. De novo urgency occurred only in 2.5% and persistent dysuria (Qmax <10 ml/s and/or post-void residual volume >120 cc) in 4%. 80% of patients were completely dry after one year and 12% were greatly improved. According to the pre-operative maximal

  4. Uroflowmetric changes, success rate and complications following Tension-free Vaginal Tape Obturator (TVT-O) operation in obese females.

    PubMed

    Fouad, Reham; El-Faissal, Yahia M; Hashem, Ahmed T; Gad Allah, Sherine H

    2017-07-01

    The goal of this study was to evaluate the outcome of Tension-free Vaginal Tape Obturator (TVT-O) operation in the treatment of urodynamic stress incontinence (USI) in obese females, with respect to uroflowmetric changes, success rate and postoperative complications. This prospective observational study included 26 patients with USI at the Obstetrics & Gynecology department-Cairo University hospital during the year 2015. The participants had body mass index (BMI)≥30. Patients underwent TVT-O operation. Follow up of the patients was performed by cough test and uroflowmetry after one week, one month, three months and six months. Postoperative complications such as groin pain, sense of incomplete emptying, need to strain to complete micturition and urinary tract infection were recorded. Comparisons between groups were done using Chi square, Phi-Cramer test for categorical variables. The mean age for the subjects was 43.58±9.01years. The mean BMI was 33.4±2.1. The success rate of TVT-O operation was 21 out of 26 patients (≈81%). Normal maximum flow rate was in 88% of patients at week one and was normal in 100% of patients at months three and six (p=0.101 & 0.101). Postoperative groin pain was the main complaint during the first week after operation and decreased significantly from week one to the 1st month postoperative (84.62% & 65.38%, P=0.041). TVT-O operation showed a high success rate in treatment of USI in obese patients without affecting the voiding function of the bladder as proven by the uroflowmetry. The main postoperative complaint was the groin pain which significantly improved after one month. Copyright © 2017 Elsevier B.V. All rights reserved.

  5. Effect of tension-free vaginal tape and TVT-obturator on lower urinary tract symptoms other than stress urinary incontinence.

    PubMed

    Ballert, Katie N; Kanofsky, Jamie A; Nitti, Victor W

    2008-03-01

    Variable effects on lower urinary tract symptoms (LUTS) other than stress urinary incontinence (SUI) have been reported after tension-free vaginal tape (TVT). We measured the effect of TVT on LUTS using the American Urological Association Symptom Index (AUASI). Patients undergoing TVT completed the AUASI pre- and post-operatively. Total scores (TS), storage scores (SS), and voiding scores (VS) were compared overall and among patients with SUI vs mixed urinary incontinence (MUI) and those who underwent TVT vs TVT-obturator (TVT-O). The mean change in TS and SS was -3.6 and -3.0. Mean reductions in TS and SS were significant in all patient subsets with no change in VS. There was no significant difference in the mean changes in TS between patients with SUI vs MUI or those undergoing TVT vs TVT-O. LUTS are improved after TVT in most patients. In general, voiding symptoms were not adversely affected.

  6. Blood loss in the space of Retzius and pelvis with tension-free vaginal tape and trans-obturator tape procedures.

    PubMed

    Huffaker, R Keith; Copas, Pleas

    2006-11-01

    The purpose of this study was to evaluate the space of Retzius and pelvis for hematoma formation and blood loss following placement of tension-free vaginal tapes (TVT) and transobturator tapes (TOT). 25 women were examined with ultrasonography on post-operative days one, two, three, four or five. One patient underwent TVT while the other 24 underwent TOT. Additional procedures were performed on most patients. No hematomas or collections of free fluid were identified post-operatively. TVT and TOT procedures are relatively safe procedures. We encountered no vascular complications in this small series of patients. Review of literature has yielded reports of infrequent complications.

  7. Comparison of the efficacy of tension-free vaginal tape obturator (TVT-O) and single-incision tension-free vaginal tape (Ajust™) in the treatment of female stress urinary incontinence: a 1-year follow-up randomized trial.

    PubMed

    Masata, Jaromir; Svabik, Kamil; Zvara, Karel; Hubka, Petr; Toman, Ales; Martan, Alois

    2016-10-01

    The aim of this study was to compare the efficacy of the tension-free vaginal tape obturator (TVT-O) and single-incision tension-free vaginal tape (Ajust™) in the treatment of stress urinary incontinence in a randomized two-arm study with a 1-year follow-up. This single-centre randomized trial compared the objective and subjective cure rates of TVT-O and Ajust using objective criteria (cough test) and subjective criteria (International Consultation on Incontinence Questionnaire short form, ICIQ-UI SF). The objective cure rate was defined as the number of patients with a negative cough stress test. Subjective cure was defined as no stress leakage of urine after surgery based on the ICIQ-UI SF. The primary outcome was to establish differences in objective and subjective cure rates between the TVT-O and Ajust groups. We also compared postoperative pain profiles using a visual analogue scale (VAS), improvement in quality of life using the ICIQ- UI SF and the Incontinence Quality of Life questionnaire, and overall satisfaction with the surgical procedure using a VAS and a five-item Likert scale. Inclusion criteria were age over 18 years, signed informed consent, and urodynamic stress urinary incontinence. Following a power calculation, 50 patients were enrolled into each group (Ajust and TVT-O). The mean follow-up after surgery was 445 days (SD 157.6 days) in the TVT-O group and 451.8 days (SD 127.6 days) in the Ajust group (p = 76.6 %). At 1 year, 47 patients were evaluated in the TVT-O group and 49 in the Ajust group. No differences in subjective cure rates or objective cure rates were observed. In the Ajust and TVT-O groups, the rates for no subjective stress leakage were 89.8 % and 91.5 %, respectively (p = 1.0, OR 1.22, 95 % CI 0.24 - 6.58), and the rates for a negative stress test were 89.8 % and 87.2 %, respectively (p = 0.76, OR 0.77, 95 % CI 0.17 - 3.32). In the Ajust group two patients reported de novo pain during sexual

  8. Surgical management of stress urinary incontinence in women: safety, effectiveness and cost-utility of trans-obturator tape (TOT) versus tension-free vaginal tape (TVT) five years after a randomized surgical trial

    PubMed Central

    2011-01-01

    Background We recently completed a randomized clinical trial of two minimally invasive surgical procedures for stress urinary incontinence, the retropubic tension-free vaginal tape (TVT) versus the trans-obturator tape (TOT) procedure. At one year postoperatively, we were concerned to find that a significant number of women had tape that was palpable when a vaginal examination was undertaken. Because the risk factors for adverse outcomes of tape surgery are not clearly understood, we are unable to say whether palpable tapes will lead to vaginal erosions or whether they merge into vaginal tissue. We do not know whether patients go on to have further adverse consequences of surgery, leading to additional cost to patients and healthcare system. Our current study is a 5 year follow-up of the women who took part in our original trial. Methods/Design All 199 women who participated in our original trial will be contacted and invited to take part in the follow-up study. Consenting women will attend a clinic visit where they will have a physical examination to identify vaginal erosion or other serious adverse outcomes of surgery, undertake a standardized pad test for urinary incontinence, and complete several health-related quality of life questionnaires (15D, UDI-6, IIQ-7). Analyses will compare the outcomes for women in the TOT versus TVT groups. The cost-effectiveness of TOT versus TVT over the 5 years after surgery, will be assessed with the use of disease-specific health service administrative data and an objective health outcome measure. A cost-utility analysis may also be undertaken, based on economic modeling, data from the clinical trial and inputs obtained from published literature. Discussion This study is needed now, because TOT and TVT are among the most frequently conducted surgical procedures for stress urinary incontinence in Canada. Because stress urinary incontinence is so common, the impact of selecting an approach that causes more adverse events, or is

  9. Comparison of Effectiveness between Tension-Free Vaginal Tape (TVT) and Trans-Obturator Tape (TOT) in Patients with Stress Urinary Incontinence and Intrinsic Sphincter Deficiency

    PubMed Central

    Kim, Hyeong Gon; Park, Hyoung Keun; Paick, Sung Hyun; Choi, Woo Suk

    2016-01-01

    Background The aim of this study was to compare the two types of mid-urethral slings for stress urinary incontinence (SUI) with intrinsic sphincter deficiency (ISD). Methods This retrospective study included patients who underwent tension-free vaginal tape (TVT) procedure or transobturator tape (TOT) procedure by a single surgeon for SUI with ISD, defined as Valsalva leak point pressure (VLPP) < 60 cmH2O in a urodynamic study. Cases of neurogenic bladder, previous SUI surgery, and concomitant cystocele repair were excluded. The primary outcome was treatment success at 12 months, defined by self-reported absence of symptoms, no leakage episodes recorded, and no retreatment. Results Among the 157 women who were included in the final analysis, 105 patients received TVT and 52 patients received TOT. Age, underlying diseases, Stamey grade, cystocele grade, and presence of urge incontinence were not significantly different between the two groups. Urodynamic parameters including maximal urethral closing pressure, detrusor overactivity, VLPP, urethral hypermobility (Q-tip ≥ 30°), were also comparable between the two groups. Success rate was significantly higher in the TVT group than in the TOT group (95.2% vs. 82.7%, p = 0.009). On multivariate analysis, only TOT surgery (OR = 3.922, 95%CI = 1.223–12.582, p = 0.022) was a risk factor for failure following surgical treatment. Conclusion TVT is more effective than TOT in treatment of female SUI with ISD. PMID:27228092

  10. Comparison of Effectiveness between Tension-Free Vaginal Tape (TVT) and Trans-Obturator Tape (TOT) in Patients with Stress Urinary Incontinence and Intrinsic Sphincter Deficiency.

    PubMed

    Kim, Hyeong Gon; Park, Hyoung Keun; Paick, Sung Hyun; Choi, Woo Suk

    2016-01-01

    The aim of this study was to compare the two types of mid-urethral slings for stress urinary incontinence (SUI) with intrinsic sphincter deficiency (ISD). This retrospective study included patients who underwent tension-free vaginal tape (TVT) procedure or transobturator tape (TOT) procedure by a single surgeon for SUI with ISD, defined as Valsalva leak point pressure (VLPP) < 60 cmH2O in a urodynamic study. Cases of neurogenic bladder, previous SUI surgery, and concomitant cystocele repair were excluded. The primary outcome was treatment success at 12 months, defined by self-reported absence of symptoms, no leakage episodes recorded, and no retreatment. Among the 157 women who were included in the final analysis, 105 patients received TVT and 52 patients received TOT. Age, underlying diseases, Stamey grade, cystocele grade, and presence of urge incontinence were not significantly different between the two groups. Urodynamic parameters including maximal urethral closing pressure, detrusor overactivity, VLPP, urethral hypermobility (Q-tip ≥ 30°), were also comparable between the two groups. Success rate was significantly higher in the TVT group than in the TOT group (95.2% vs. 82.7%, p = 0.009). On multivariate analysis, only TOT surgery (OR = 3.922, 95%CI = 1.223-12.582, p = 0.022) was a risk factor for failure following surgical treatment. TVT is more effective than TOT in treatment of female SUI with ISD.

  11. One-year follow-up of tension-free vaginal tape (TVT) and trans-obturator suburethral tape from inside to outside (TVT-O) for surgical treatment of female stress urinary incontinence: a prospective randomised trial.

    PubMed

    Zullo, Marzio Angelo; Plotti, Francesco; Calcagno, Marco; Marullo, Elettra; Palaia, Innocenza; Bellati, Filippo; Basile, Stefano; Muzii, Ludovico; Angioli, Roberto; Panici, Pierluigi Benedetti

    2007-05-01

    To compare tension-free vaginal tape (TVT) and trans-obturator suburethral tape from inside to outside (TVT-O) for surgical treatment of stress urinary incontinence (SUI) for complications (primary end point) and success rate (secondary end point). Seventy-two consecutive patients, with a mean age of 53.2 yr (range: 38-69 yr) and affected by SUI, were included in this randomised controlled trial. After preoperative assessment, patients were randomly allocated to the TVT or TVT-O procedure. Operative time, perioperative complications, and hospital stay were prospectively recorded. Cure of SUI was defined as no leakage of urine during the stress test at urodynamic testing at the 12-mo evaluation. The Wilcoxon signed rank sum test, Mann-Whitney U test, McNemar test, and Fisher exact test were used to verify statistical significance, set at p<0.05. All patients were evaluable at the 12-mo follow-up. The characteristics of patients were well balanced between groups after randomisation. The mean operative time was significantly shorter in the TVT-O group. Perioperative complications were significantly more common after the retropubic approach (5% and 27% in TVT-O and TVT groups, respectively, p<0.04). The groups did not differ significantly in intraoperative blood loss, hospital stays, and time to return to normal activities. Sixty-five patients (90%) were successfully treated for SUI 12 mo after the operation (89% and 91% for TVT-O and TVT groups, respectively). Both techniques appear to be equally effective in the surgical treatment of SUI. However, TVT-O had a shorter operative time and lower overall perioperative complication rate.

  12. Surgeon-tailored polypropylene mesh as a tension-free vaginal tape-obturator versus original TVT-O for the treatment of female stress urinary incontinence: a long-term comparative study.

    PubMed

    ElSheemy, Mohammed S; Fathy, Hesham; Hussein, Hussein A; Elsergany, Ragheb; Hussein, Eman A

    2015-10-01

    The objective of the study was to compare the safety and efficacy of surgeon-tailored polypropylene mesh (STM) through tension-free vaginal tape-obturator (TVT-O) versus original TVT-O in the treatment of stress urinary incontinence (SUI) aiming to decrease the cost of treatment. This is important in developing countries due to limited health care resources. A retrospective cohort study was done at the Urology and Gynecology Departments (dual-center), Cairo University from May 2007 to June 2010. Women evaluated by cough stress test, Stress and Urge Incontinence and Quality of Life Questionnaire (SUIQQ), maximum flow rate (Qmax), and abdominal leak point pressure (ALPP) with follow-up for at least 48 months were included. Patients with post-void residual urine > 100 ml, bladder capacity < 300 ml, or impaired compliance were excluded. The effect of different factors on outcome was compared between both groups pre- and postoperatively using the paired t, Wilcoxon signed rank, McNemar, chi-square, Fisher's exact, independent t, or Mann-Whitney tests. STM and TVT-O were inserted in 79 and 66 women, respectively. Intrinsic sphincter deficiency, ALPP, previous surgeries, associated urgency, urgency urinary incontinence (UUI), and prolapse were comparable in both groups. Operative duration was longer in STM by 10 min. No significant difference was found between both groups in complications (p = 0.462), cure (p = 0.654), and different indices of SUIQQ. In STM, 74 (93 %) were cured and 3 (4 %) improved, while SUI persisted in 2 (2 %) patients. In TVT-O, 59 (89 %) were cured and 4 (6 %) improved, while failure was detected in 3 (4 %) patients. The 5-year outcome is comparable between STM and TVT-O. Furthermore, STM is more economical due to our resterilizable modified helical passers and the cheap polypropylene mesh.

  13. Objective and subjective cure rates after trans-obturator tape (OBTAPE) treatment of female urinary incontinence.

    PubMed

    Deval, Bruno; Ferchaux, Jérome; Berry, Richard; Gambino, Sandro; Ciofu, Calin; Rafii, Arash; Haab, François

    2006-02-01

    To evaluate the safety and efficacy of a thermally bonded nonwoven polypropylene mesh in a transobturator suburethral tape procedure (OBTAPE), Mentor-Porges, Le Plessis Robinson, France) for women with stress urinary incontinence. Between January 2003 and January 2005, 129 consecutive women (mean age 57.2 years) underwent OBTAPE) in two academic centers. All the patients had stress urinary incontinence preoperatively. Detrusor instability was ruled out by cystometry. The women were evaluated 1, 6 and 12 months postoperatively. The objective cure rate was evaluated by clinical examination and the subjective cure rate was assessed using the KHQ and BFLUTS questionnaire. Mean follow-up was 17.2+/-4.7 months (range 4 to 28 months). The objective and subjective cure rates were respectively 89.9% and 77.5%. Most of the patients received general anesthesia (85.3%). Urinary retention was observed in two women (1.5%), necessitating tape adjustment. Voiding difficulties were observed in 7 cases (5.4%) necessitating intermittent self-catheterization for 4.2+/-2.4 days (range 1 to 7 days). Seven patients developed vaginal erosion (one with vaginal extrusion, and two with an obturator abscess). Complete mesh removal was necessary in 6 patients, four of whom had recurrent stress urinary incontinence. Our results suggest that the OBTAPE) is an effective treatment for women with stress urinary incontinence. However, vaginal mesh erosion occurred in 6.2% of women, and this implies the need for careful follow-up.

  14. Chronic vaginal discharge and left leg edema after a transobturator tape procedure.

    PubMed

    Kim, Tae-Hee; Lee, Hae-Hyeog; Kim, Jun-Mo

    2014-05-01

    We report on a patient who underwent total vaginal hysterectomy for urinary incontinence 8 years previously with a sling operation using transobturator tape (TOT). She was admitted to our hospital after complaints of vaginal discharge, foul odor, and bleeding, left thigh pain, and edema. Magnetic resonance imaging (MRI) and computed tomography (CT) revealed a fistula tract from the vagina or urethra with remnant sling tape. We removed the remnant tape using intraoperative ultrasonography. This case exemplifies the rare occurrence of a vaginal fistula extending to the obturator, adductor, and pectineus muscles combined with myositis after TOT placement. It is important that urogynecologists recognize that TOT procedures may result in complications accompanied by common recurrent vaginal symptoms, such as vaginal odor and spotting, which can be identified by MRI or CT.

  15. Modified prepubic TVT-obturator tape procedure versus the conventional method: a preliminary study.

    PubMed

    Long, Cheng-Yu; Wu, Ming-Ping; Wang, Chiu-Lin; Lin, Kun-Ling; Liu, Cheng-Min; Wu, Shu-Hui; Juan, Yung-Shun

    2013-12-01

    To compare the efficacy and safety of the modified prepubic tension-free vaginal tape-obturator (PTVT-O) system procedure with the original TVT-O methods. One hundred and ninety women with urodynamic stress incontinence (USI) were included in this study (93 cases in the TVT-O group and 97 in the PTVT-O group). Clinical assessments before and one year after surgery included urinalyses, 1-h pad tests, urodynamic studies, and a personal interview with the overactive bladder symptom score (OABSS) questionnaire. There were no differences between the two groups in mean age, parity, menopausal status, mean operative time and subjective cure rates (P>0.05), but the efficacy of surgery (cure and improvement) in the PTVT-O group was significantly higher than that in the TVT-O group (P=0.038). Complication rates and visual analog scale (VAS) scores were found to be similar (P>0.05). OABSS decreased significantly after surgery in both groups (P<0.05) although all urodynamic parameters revealed no significant difference after both procedures (P>0.05). Our modified procedure is a safe and effective treatment for female USI. It has an advantage over the original TVT-O with better surgical efficacy and comparable postoperative pain, although the follow-up times in this study are different. Copyright © 2013. Published by Elsevier Ireland Ltd.

  16. Surgical removal of a large vaginal calculus formed after a tension-free vaginal tape procedure.

    PubMed

    Zilberlicht, Ariel; Feiner, Benjamin; Haya, Nir; Auslender, Ron; Abramov, Yoram

    2016-11-01

    Vaginal calculus is a rare disorder which has been reported in association with urethral diverticulum, urogenital sinus anomaly, bladder exstrophy and the tension-free vaginal tape (TVT) procedure. We report a 42-year-old woman who presented with persistent, intractable urinary tract infection (UTI) following a TVT procedure. Cystoscopy demonstrated an eroded tape with the formation of a bladder calculus, and the patient underwent laser cystolithotripsy and cystoscopic resection of the tape. Following this procedure, her UTI completely resolved and she remained asymptomatic for several years. Seven years later she presented with a solid vaginal mass. Pelvic examination followed by transvaginal ultrasonography and magnetic resonance imaging demonstrated a large vaginal calculus located at the lower third of the anterior vaginal wall adjacent to the bladder neck. This video presents the transvaginal excision and removal of the vaginal calculus.

  17. Management of vaginal extrusion after tension-free vaginal tape procedure for urodynamic stress incontinence.

    PubMed

    Giri, Subhasis K; Sil, Debasri; Narasimhulu, Girish; Flood, Hugh D; Skehan, Mark; Drumm, John

    2007-06-01

    To report our experience in the management of vaginal extrusion after the tension-free vaginal tape (TVT) procedure for urodynamic stress incontinence. Five patients diagnosed with vaginal extrusion after a TVT procedure performed at our institution were identified. We reviewed the patients' records retrospectively. The interval from TVT placement to diagnosis, presenting symptoms and signs, duration of symptoms, diagnostic test findings, treatment, and postoperative results were recorded. Patients were followed up for at least 12 months. From January 2001 to June 2004, a total of 166 patients underwent the TVT procedure. Of these, 5 patients (3%) were diagnosed with isolated vaginal extrusion 4 to 40 months postoperatively. No cases of urethral or bladder erosion occurred in this series. The symptoms included vaginal discharge, pain, bleeding, and dyspareunia. The eroded margin of the vaginal mucosa was trimmed, mobilized, and closed over the tape with interrupted vertical mattress sutures in a single layer using 2-0 polyglactin 910 to avoid mucosal inversion. All patients remained symptom free without any evidence of defective healing or additional extrusion at a minimal follow-up of 12 months. Primary reclosure of the vaginal mucosa over the TVT tape is an effective first-line treatment option for vaginal extrusion without compromising continence. Patients undergoing the TVT procedure should be adequately counseled about the possibility of this complication and the available treatment options.

  18. Ultrasound assessment of tension-free vaginal tape (TVT).

    PubMed

    Flock, F; Kohorst, F; Kreienberg, R; Reich, A

    2011-01-01

    To date, no standardization for the visualization of tension-free vaginal tape (TVT) has been established in clinical practice. The aim of this prospective observational study was to evaluate the shape and position of the tape using ultrasound and to compare this data with clinical postoperative results. In a three-year period, 296 patients with clinically and urodynamically proven stress urinary incontinence (SUI) were treated with TVT and received follow-up in our department. An additional 12 patients, who were initially treated in other hospitals and had postoperative problems, were included in this study. Depending on the outcome after 3 months, the patients were divided into groups with and without specific disorders. The TVT was evaluated by introital ultrasound. The position of the tape was established by its location in relation to the urethral length and the distance to the hypoechoic center of the urethra (HCU). A suitable TVT position was determined in patients without any postoperative disorders. The mean value for the TVT position at rest in relation to the urethral length was 61 %. The distance to the HCU was 4.6 ± 1.5 mm. In patients with persistent SUI, the tape was more often located under the inner (3 % vs. 0 %) or outer quarter (29 % vs. 13 %, p = 0.004). In patients with residual volume, the distance to the urethra was significantly lower (2.7 vs. 4.6, p < 0.001). TVT may be regularly investigated using ultrasound. In combination with the clinical outcome, it represents an important method of evaluating the tape and assists in the planning of a future therapeutic course of action in cases of postoperative problems. © Georg Thieme Verlag KG Stuttgart · New York.

  19. Trans-Obturator-Tape (T.O.T.) "outside-in" approach in surgical treatment of female stress urinary incontinence.

    PubMed

    Jovanović, M; Džamić, Z; Aćimović, M; Kajmaković, B; Pejčić, T

    2014-01-01

    The aim of the study was to analyzed the efficacy and safety of a minimally invasive surgical procedure using the Trans- Obturator-Tape with "outside-in" approach for treatment female stress urinary incontinence. 171 women with stress urinary incontinence (SUI) associated with urethral hypermobility, underwent the T.O.T. procedure (March 2010 to January 2014). 27 patients were previously operated for incontinence. Mean age was 59 years (37-80). 6 patients were having mixed incontinence, and 51 had SUI with urgencies. A non-elastic, polypropylene tape was placed under the mid-urethra. The surgical placement technique utilises a trans-obturator percutaneous approach. All patients underwent post-operative clinical examination, cough-stress test (full bladder), uroflowmetry, and post-voiding residual assessment. Mean follow-up was 22 months (4-45). At 12 months follow-up 91,2% of the patients were completely cured. The overall peri-operative complication rate was 6.4% with no vascular, nerve or bowel injury. 5 patients (2.9%) had post-operative urinary retention. The present study confirms the results obtained by the instigator of the technique, E. Delorme, and allows us to consider T.O.T. as an effective and safe technique for the treatment of female stress urinary incontinence.

  20. High rate of vaginal erosions associated with the mentor ObTape.

    PubMed

    Yamada, Brian S; Govier, Fred E; Stefanovic, Ksenija B; Kobashi, Kathleen C

    2006-08-01

    The transobturator tape method is a newer surgical technique for the treatment of stress urinary incontinence. Limited data exist related to complications with this approach or the types of mesh products used. We report our experience with vaginal erosions associated with the Mentor ObTape and American Medical Systems Monarc transobturator slings. Beginning in December 2003 selected female patients with anatomic urinary incontinence were prospectively followed after placement of the Mentor ObTape. Beginning in January 2004 we also began using the American Medical Systems Monarc in similar patients. Patients were admitted overnight after surgery, discharged on oral antibiotics, and seen in the clinic at 6 weeks postoperatively. A total of 67 patients have undergone placement of the Mentor ObTape and 9 of those patients (13.4%) have had vaginal extrusions of the sling. Eight patients reported a history of persistent vaginal discharge. One patient presented initially to an outside facility with a left thigh abscess tracking to the left inguinal incision site. Each patient was taken back to the operating room for mesh removal. A total of 56 patients have undergone placement of the AMS Monarc and none have had any vaginal erosions. Our high rate of vaginal extrusion using the ObTape has led us to discontinue the use of this product in our institution. Continued followup of all of these patients will be of critical importance.

  1. Usage of a Trans-Obturator-Tape (T.O.T.) "outside-in" approach in surgical treatment of female stress urinary incontinence.

    PubMed

    Jovanovic, Mirko; Vuksanović, Aleksandar; Dzamić', Zoran; Aćimović, Miodrag; Radovanović, Milan; Djurasić, Ljubomir

    2011-01-01

    The aim of the study was to analyzed the efficacy and safety of a new minimally invasive surgical procedure using the Trans-Obturator-Tape with"outside-in" approach for treatment female stress urinary incontinence. 31 women with stress urinary incontinence (SUI) associated with urethral hypermobility, underwent the T.O.T. procedure (March 2010 to January 2011). 5 patients were previously operated for incontinence. Mean age was 59 years (37-80). 10 patients were having mixed incontinence. A non-elastic, polypropylene tape was placed under the mid-urethra. The surgical placement technique utilises a trans-obturator percutaneous approach. All patients underwent post-operative clinical examination, cough-stress test (full bladder), uroflowmetry, and post-voiding residual assessment. Mean follow-up was 5 months (1-9). At 6 months follow-up 96.7% of the patients were completely cured. The overall peri-operative complication rate was 6.4% with no vascular, nerve or bowel injury. One patients (3.4%) had post-operative urinary retention. The present study confirms the results obtained by the instigator of the technique, E. Delorme, and allows us to consider T.O.T. as an effective and safe technique for the treatment of female stress urinary incontinence.

  2. Surgical treatment of female stress urinary incontinence with a trans-obturator-tape (T.O.T.) Uratape: short term results of a prospective multicentric study.

    PubMed

    Costa, P; Grise, P; Droupy, S; Monneins, F; Assenmacher, C; Ballanger, P; Hermieu, J F; Delmas, V; Boccon-Gibod, L; Ortuno, C

    2004-07-01

    The aim of the study was to assess the efficacy and safety of a new minimally invasive surgical procedure using the Trans-Obturator-Tape Uratape to treat female stress urinary incontinence. 183 women with stress urinary incontinence (SUI) associated with urethral hypermobility, underwent the T.O.T. procedure (October 2001 to March 2003). 26 patients were previously operated for incontinence. 26 patients were operated at the same time for their genital prolapse. Mean age was 56 years (29-87). 50/183 patients were having mixed incontinence. A non-elastic, polypropylene tape (UraTape, Mentor-Porgès) with a silicon coated central part was placed under the mid-urethra. The surgical placement technique utilises a trans-obturator percutaneous approach. All patients underwent post-operative clinical examination, cough-stress test (full bladder), uroflowmetry, and post-voiding residual assessment. Mean follow-up was 7 months (1-21). At 1 year follow-up 80.5% of the patients were completely cured and 7.5% were improved. The overall peri-operative complication rate was 2.2% with no vascular, nerve or bowel injury. 6 patients (3.3%) had post-operative urinary retention. The present multicentric study confirms the results obtained by the instigator of the technique, E. Delorme, and allows us to consider T.O.T. as an effective and safe technique for the treatment of female stress urinary incontinence, alone or in combination with prolapse repair. Copyright 2004 Elsevier B.V.

  3. TVT and TVT-Obturator: comparison of two operative procedures.

    PubMed

    Neuman, Menahem

    2007-03-01

    To compare two anti-incontinence operations: the tension-free vaginal tape (TVT) and the TVT-Obturator for the first two 75-patient groups. One surgeon operated on two patient groups with urodynamically proven urinary stress incontinence. The first 75-patient group in 1998 included the first TVT procedures performed according to Ulmsten [Ulmsten U, Henriksson L, Johnson P, Varhos G. An ambulatory surgical procedure under local anesthesia for treatment of female urinary incontinence. Int Urogynecol J 1996;7:81-6]. Follow-up lasted for 5-6 years. The second 75-patient group in 2004 included the first TVT-Obturator operations performed according to [De Leval J. Novel surgical technique for the treatment of female stress urinary incontinence: transobturator vaginal tape inside-out. Eur. Urol. 2003;44:724-30]. Follow-up lasted for 6-13 months. The two patient groups were similar from the demographic and therapeutic points of view. The TVT-Obturator procedure required neither bladder catheterization nor intra-operative diagnostic cystoscopy. TVT-related bladder penetration (8.0%), post-operative voiding difficulties (5.0%), intra-operative bleeding (4.0%), post-operative field infection (2.7%), and post-operative pelvic floor relaxation (1.3%) were not noted with the TVT-Obturator. The early therapeutic failure rates were 2.7% for the TVT and 1.3% for the TVT-Obturator, and neither bowel nor urethral injuries were recorded. The surgeons' learning curves of these two minimally invasive surgical procedures for the treatment of female urinary stress incontinence are comparable. The safety and cost-effectiveness of the TVT are well-established. The TVT-Obturator, a novel mid-urethral sling, was designed to overcome some of the TVT-related operative complications. The TVT-Obturator patients seem to have less intra-operative and post-operative surgical complications than the TVT patients. However, long-term comparative data collection is required prior to drawing solid

  4. An in-house Composix™-based pubovaginal sling trial for female stress urinary incontinence: Five-year comparative followup to tension-free and transobturator vaginal tapes

    PubMed Central

    Ben-Zvi, Tal; Moore, Katherine; Haidar, Nadim; Gregoire, Mireille

    2017-01-01

    Introduction We compared the efficacy of three slings in the long-term treatment of stress urinary incontinence (SUI): tension-free vaginal tape (TVT), vaginal tape-obturator (TVT-O), and an in-house two-layered polypropylene mesh with a submicronic polytetrafluoroethylene (Composix™). Our primary endpoint was the objective measurement of continence (24-hour pad test). Secondarily, we measured the satisfaction and complication rates. Methods This prospective, non-randomized study included 128 patients with SUI. Preoperative evaluation included medical history, physical exam, 24-hour pad test, Urinary Incontinence Quality of Life Scale (IQOL), FPSUND, and global satisfaction questionnaires. Patients were followed at one month postoperative, biannually for two years, and then annually for a total of five years. Followup visits included a focused questionnaire, physical exam, satisfaction questionnaire, 24-hour pad test, IQOL, and FPSUND questionnaires. Results Composix, TVT, and TVT-O groups included 60, 34, and 34 patients, respectively. No significant differences were found in baseline characteristics except for the pad test. Length of catheterization was the only immediate operative significant parameter (Composix 4.7 days vs. TVT 1.1 days vs. TVT-O 2.6 days; p=0.03). The entire cohort had significant improvements in their IQOL, FPSUND, and pad test at one and four years (p<0.01). The cohort-wide 24-hour pad test average weight was 30.4 g preoperatively vs. 5 g at 12 months (p<0.00001) (Composix 37 to 5 g, TVT 83 to 4 g, and TVT-O 55 to 5 g). The Composix group had a higher number of minor complications (Clavien I, II) and secondary procedures. Conclusions This single-surgeon cohort with five-year followup demonstrated a large improvement and maintenance of continence in all three surgical groups. The Composix-based sling provided comparable continence outcomes at a fraction of the cost; however, its increased morbidity and higher complication rate raise

  5. [A comparative study on treating femal stress urinary incontinence with TVT-Abbrevo and TVT-Obturator].

    PubMed

    Li, W L; Lu, Z W; Li, F P; Yu, H Y

    2016-07-26

    To compare the effectiveness and complications of TVT-Abbrevo (tension-free vaginal tape-Abbrevo) and TVT-Obturator (tension-free vaginal tape-obturator) for the treatment of female stress urinary incontinence (SUI). From Nov.2012 to Nov.2013, 117 patients suffering from SUI were treated with TVT-Abbrebo (n=79) or TVT-Obturator (n=38) procedure, the clinical efficacy and operation-correlated complications were observed. A total of 117 cases, 107 cases of urinary incontinence symptoms disappeared completely, 10 cases were improved. 72 cases (91.1%) were cured and 7 cases (8.9%) were improved in TVT-Abbrevo group; 35 cases (92.1%) were cured and 3 cases (7.9%) were improved in TVT-Obturator group. No significant differences could be found for the curing rates between two groups (P>0.05). Compared with the TVT-Obturator group, the TVT-Abbrevo group had less patients complaining of inner thigh pain at 24 h and 1 w after surgery (P<0.05). No significant differences were observed for the incidence of inner thigh pain at 1m and 1y after surgery between TVT-Abbrevo and TVT-Obturator group (P>0.05). No intraoperative complications such as blood vessel, nerve, bladder damage were recorded and no postoperative retropubic hematoma, tape adjustment and other complications occurred in two goups. No recurrence after 1 year follow-up. The study shows that TVT-Abbrevo procedure is safe and efficacy in treatment of SUI, and associated with low incidence of recent postoperative inner thigh pain.

  6. Results of the tension-free vaginal tape procedure for stress incontinence: patient's perspective.

    PubMed

    Manikandan, Ramaswamy; Kujawa, Magda; Pearson, Evelyn; O'Reilly, Patrick H; Brown, Stephen C W

    2004-04-01

    To evaluate the results of the tension-free vaginal tape procedure (TVT) from a patient's perspective. Between May 1999 and January 2002, 90 patients underwent a TVT for genuine stress incontinence (GSI) and mixed incontinence. Prior to the procedure, GSI was confirmed by clinical examination and urodynamic studies. Results were then audited from patient notes and the same patients were sent questionnaires to examine results from a patient perspective. Overall response rate to the questionnaire was 70 (77%). The mean age of the patients was 50.4 years (range 31-83 years). Sixty-one patients had spinal anesthesia, seven had general anesthesia and two had local anesthesia. Mean hospital stay was 3.36 days (range 2-14 days) and mean period from the operation to the time of the survey and audit was 16.34 months (range 3-28; SD 6.92). Thirty-nine (56%) of the 70 patients who answered said that the operation had cured their incontinence, 16 (23%) had an improvement in their symptoms, 7 (10%) had worsening of their symptoms and 8 (11%) felt that the operation did not make any difference. The overall success rate according to the patients' perspective was 79%, whereas our audit showed an overall success rate of 86% (77% and 82%, respectively, when we compared only the 66 patients who had both notes and replies available for analysis). Although a patient's perception regarding the success of TVT tends to differ from that of a clinician, it was not found to be statistically significant (P = 0.22, McNemar test). The TVT is a very successful operation, but realistic cure rates should be offered to patients.

  7. Transfascial vaginal tape (TFT): a simple, safe and cost-effective procedure for stress urinary incontinence. A preliminary study.

    PubMed

    Foglia, Giovanni; Mistrangelo, Emanuela; Lijoi, Davide; Alessandri, Franco; Ragni, Nicola

    2007-07-01

    To analyse prospectively the effectiveness of a new simple, minimally invasive, and cost-effective technique for the treatment of female urinary stress incontinence: the transfascial vaginal tape (TFT). In a prospective study, we enrolled 45 women undergoing TFT with or without hysterectomy and/or another pelvic reconstructive procedure between 1st December 2003 and 31st December. TFT consists of a tension-free urethrosuspension using a sling located at the mid-urethral level and placed laterally in the endopelvic fascia previously perforated. Follow-up evaluations were established at 3 and 6 months and at 1 year after the operation. During each follow-up, women underwent cough stress test and they answered to the "Incontinence quality of life questionnaire" (I-QOL), to the Patient Global Impression of Severity (PGI-S) and of Improvement (PGI-I) questions. Thirty-nine patients (88.9%) had a follow-up examination 1 year after surgery. Of these, 30 (76.9%) were defined cured, 6 (15.4%) improved and 3 (7.7%) failed. TFT procedure can be considered a simple, safe and cost-effective procedure for the treatment of stress urinary incontinence and can be an alternative to tension-free vaginal tape or transobturator route for sub-urethral tape procedures.

  8. The comparison of an inexpensive-modified transobturator vaginal tape versus TVT-O procedure for the surgical treatment of female stress urinary incontinence.

    PubMed

    Zhang, Yan; Jiang, Min; Tong, Xiao-Wen; Fan, Bo-Zhen; Li, Huai-Fang; Chen, Xin-Liang

    2011-09-01

    To compare the safety and efficacy of an inexpensive-modified transobturator vaginal tape procedure with the transobturator tension-free vaginal tape (TVT-O) procedure for the surgical treatment of female stress urinary incontinence (SUI). Patients with SUI were randomly allocated to either the test group receiving the inexpensive-modified transobturator vaginal tape procedure or the control group receiving the GYNECARE TVT-O procedure. Treatment outcomes and Quality-of-life scores were recorded and analyzed between two groups. A total of 156 patients were enrolled in this trial. Eighty patients underwent the modified transobturator vaginal tape procedure. Among them 75(93.8%) were cured and 5(6.2%) were improved. The rest of the 76 patients underwent the GYNECARE TVT-O procedure with a 92% (70 of 76) cure rate and an 8% (6 of 76) improvement rate. No inefficient or aggravated cases occurred in both groups. The success rates between groups had no significant statistic difference (p > 0.05). The operative time, blood loss, hospital stay, and medical cost were significantly lower in the test group (p < 0.01); the increases in Quality-of-life scores were comparable between groups. The modified transobturator vaginal tape procedure is an efficacious and economic surgical treatment for female SUI. Copyright © 2011. Published by Elsevier B.V.

  9. Effectiveness of Retropubic Tension-Free Vaginal Tape and Transobturator Inside-Out Tape Procedures in Women With Overactive Bladder and Stress Urinary Incontinence

    PubMed Central

    Han, Ji-Yeon; Choo, Myung-Soo; Lee, Young-Suk; Seo, Ju Tae; Kim, Jang Hwan; Kim, Young Ho

    2013-01-01

    Purpose We compared the effectiveness of the retropubic tension-free vaginal tape (TVT) and the transobturator inside-out tape (TVT-O) in treating symptoms of overactive bladder (OAB) in women with stress urinary incontinence (SUI). Methods Women with urodynamic SUI and OAB (mean urgency episodes ≥1 and frequency ≥8/24 hours on a 3-day voiding diary) were assigned to the TVT or TVT-O group. Preoperative measures were based on a urodynamic study, 3-day voiding diary, the Bristol Female Lower Urinary Tract Symptoms questionnaire (BFLUTSSF), and the urgency perception scale (UPS). At 12 postoperative months, the 3-day voiding diary, symptoms questionnaire, patient satisfaction, and standing stress test were assessed. The primary endpoint was change in the number of urgency episodes/24 hours from baseline to 12 months. Results In this group of 132 women, 42 received TVT and 90 received TVT-O. The mean urgency episodes/24 hours decreased from 6.3±5.5 to 1.6±3.2 in the TVT group and from 5.1±4.4 to 1.8±3.0 in the TVT-O group. The mean percent change was significantly greater after TVT than after TVT-O (73% vs. 60%, P=0.049). All subscales of BFLUTSSF and UPS were significantly improved using either method, with significantly greater improvement seen in the quality of life (QoL) domain after TVT (P=0.002). There were no significant differences in the cure and satisfaction rates between the two groups. Conclusions Intervention with the TVT or the TVT-O significantly improved symptoms of OAB in women with SUI and OAB. Urgency and QoL significantly improved after TVT compared with that after TVT-O. PMID:24143294

  10. Efficacy and Safety of Tension-Free Vaginal Tape-Secur Mini-Sling Versus Standard Midurethral Slings for Female Stress Urinary Incontinence: A Systematic Review and Meta-Analysis

    PubMed Central

    Wang, Tao; Zhang, Yong

    2015-01-01

    Purpose: To assess the efficacy and safety of tension-free vaginal tape (TVT)-Secur for stress urinary incontinence (SUI). Methods: A literature review was performed to identify all published trials of TVT-Secur. The search included the following databases: MEDLINE, Embase, and the Cochrane Controlled Trial Register. Results: Seventeen publications involving a total of 1,879 patients were used to compare TVT-Secur with tension-free obturator tape (TVT-O) and TVT. We found that TVT-Secur had significant reductions in operative time, visual analog score for pain, and postoperative complications compared with TVT-O. Even though TVT-Secur had a significantly lower subjective cure rate (P<0.00001), lower objective cure rate (P<0.00001), and higher intraoperative complication rate, compared with TVT-O at 1 to 3 years, there was no significant difference between TVT-Secur and TVT-O in the subjective cure rate (odds ratio [OR], 0.49; 95% confidence interval [CI], 0.22–1.08; P=0.08), objective cure rate (OR, 0.49; 95% CI, 0.22–1.09; P=0.08), or complications at 3 to 5 years. Moreover, TVT-Secur had significantly lower subjective and objective cure rates compared with TVT. Conclusions: This meta-analysis indicates that TVT-Secur did not show an inferior efficacy and safety compared with TVT-O for SUI in 3 to 5 years, even though displaying a clear tread toward a lower efficacy in 1 to 3 years. Considering that the safety is similar, there are no advantages in using TVT-Secur. PMID:26739179

  11. Comparison between three mini-sling surgical procedures and the traditional transobturator vaginal tape technique for female stress urinary incontinence

    PubMed Central

    LEANZA, V.; INTAGLIATA, E.; LEANZA, A.; FERLA, F.; LEANZA, G.; VECCHIO, R.

    2014-01-01

    Objectives To compare mini-sling and traditional tension-free operations for female stress urinary incontinence. Study design A systematic review of articles in the Literature published between 2002 and 2012, was conducted. A Pubmed search was performed. Primary outcomes were subjective and objective cure rates at 12 months comparing the three single-incision mini-slings techniques (TVT-Secur, MiniArc and Monarc systems) with the standard mid-urethral sling procedure TOT (Transobturator Vaginal Tape). Secondary outcomes included peri-operative (vaginal and/or bladder perforation, urine retention, urinary tract infection, bleeding, pain) and post-operative (mesh exposure, de novo urgency, and dyspareunia) complications. Results In term of objective cure rate at 12 month after surgery, it is evident that TOT at first, and MiniArc are the most effective procedures. The incidence of post-operative urgency and UTI was lower in TOT technique, while vaginal perforation was described in equal frequency both in TOT and in MiniArc procedures. The advantages of the three above described mini-invasive techniques seem to consist into lower cases of urinary retention, pain and bleeding. Furthermore, bladder perforation and bleeding are not described in the Literature for TVT-Secur and Monarc systems. Conclusions Some single-incision slings look promising and as effective as conventional sub-urethral slings at short term evaluation. However, at this moment a clear statement in favor of the widespread use of single-incision slings cannot be made. More studies must define the efficacy of these techniques. PMID:24841685

  12. One Year Outcomes of Tension-Free Vaginal Tape (TVT) Mid-Urethral Slings in Overweight and Obese Women

    PubMed Central

    Killingsworth, Lindsay B.; Wheeler, Thomas L.; Burgio, Kathryn L.; Martirosian, Tovia E.; Redden, David T.; Richter, Holly E.

    2011-01-01

    Introduction The purpose of this study was to assess the impact of body mass index (BMI) on tension-free vaginal tape (TVT) success rates, patient satisfaction, and complications one year following surgery. Methods Baseline and one-year post-surgery outcomes were abstracted, including Urogenital Distress Inventory (UDI-6) scores, Incontinence Impact Questionnaire (IIQ-7) scores, and patient satisfaction ratings. Multivariable logistic and linear regression analyses were performed to examine relationships between outcomes and BMI. Results 195 subjects with a mean age of 59.3 ±12.6 were included. There was significant improvement within each group (all p-values <0.01) in total UDI-6 and IIQ-7 scores from baseline to one year post-surgery; all groups had high patient satisfaction. No differences in improvement or complications rates were observed among the BMI cohorts (all p-values >0.05) Conclusion Differential counseling of overweight or obese women regarding outcomes of the TVT procedure is not supported by these results; longer follow-up is warranted. PMID:19448965

  13. One-year outcomes of tension-free vaginal tape (TVT) mid-urethral slings in overweight and obese women.

    PubMed

    Killingsworth, Lindsay B; Wheeler, Thomas L; Burgio, Kathryn L; Martirosian, Tovia E; Redden, David T; Richter, Holly E

    2009-09-01

    The purpose of this study was to assess the impact of body mass index (BMI) on tension-free vaginal tape (TVT) success rates, patient satisfaction, and complications 1 year following surgery. Baseline and 1-year postsurgery outcomes were abstracted, including Urogenital Distress Inventory (UDI-6) scores, Incontinence Impact Questionnaire (IIQ-7) scores, and patient satisfaction ratings. Multivariable logistic and linear regression analyses were performed to examine relationships between outcomes and BMI. Subjects (N = 195) with a mean age of 59.3 +/- 12.6 were included. There was significant improvement within each group (all p values <0.01) in total UDI-6 and IIQ-7 scores from baseline to 1 year postsurgery; all groups had high patient satisfaction. No differences in improvement or complications rates were observed among the BMI cohorts (all p values >0.05). Differential counseling of overweight or obese women regarding outcomes of the TVT procedure is not supported by these results; longer follow-up is warranted.

  14. Vaginitis

    MedlinePlus

    ... discharge usually is thin and dark or dull gray, but may have a greenish color. Itching is ... trichomoniasis? Signs of trichomoniasis may include a yellow-gray or green vaginal discharge. The discharge may have ...

  15. Vaginitis.

    PubMed

    Friedrich, E G

    1985-06-01

    Vaginitis is one of the most common complaints of women in the United States today. About 90% of patients with this problem suffer from infection of the vagina caused by Candida, Gardnerella, or Trichomonas. The diagnosis and effective treatment of these common infections depend on accurate identification of the entity, effective specific therapy, and restoration of the normal ecosystem of the vagina. At the same time women should be made aware that not all discharge means infection and that any attempts at self-treatment may only worsen their condition. Proper hygiene habits, dietary control, and management of stress are all helpful factors in the control of recurrent vaginal infections.

  16. Randomized controlled study of MONARC® vs. tension-free vaginal tape obturator (TVT-O®) in the treatment of female urinary incontinence: comparison of 3-year cure rates.

    PubMed

    Park, Yoo Jun; Kim, Duk Yoon

    2012-04-01

    Transobturator approaches to midurethral sling surgery are one of the most commonly performed operations for female stress urinary incontinence throughout the world. However, very few results of randomized clinical trials of transobturator midurethral sling surgery (MONARC vs. TVT-O) for the treatment of female urinary incontinence have been reported. In this study, we compared the 3-year follow-up cure rates of these two procedures. From July 2006 to June 2008, 74 patients who had undergone MONARC (35 patients) or TVT-O (39 patients) were included in the study and were analyzed prospectively. The mean follow-up duration of both groups was 39.2 months. Preoperative and postoperative evaluations included physical examination, uroflowmetry and postvoid residual measurement, involuntary urine loss with physical activity, and urinary symptoms. Cure of female urinary incontinence was defined as patient report of no loss of urine upon physical activity. The patients' satisfaction after treatment was rated as very satisfied, satisfied, equivocal, and unsatisfied. Very satisfied and satisfied were considered as the satisfied rate. There were no significant differences in preoperative patient characteristics, postoperative complications, or success rate between the two groups. The cure rate of the MONARC and TVT-O groups was 85.7% and 84.6%, respectively. The patient satisfaction (very satisfied, satisfied) rate of the MONARC and TVT-O groups was 82.8% and 82.1%, respectively. The MONARC and TVT-O procedures were equally efficient for the treatment of female urinary incontinence, with maintenance of high cure rates for 3 years. Longer follow-up is needed to confirm these results.

  17. Randomized Controlled Study of MONARC® vs. Tension-free Vaginal Tape Obturator (TVT-O®) in the Treatment of Female Urinary Incontinence: Comparison of 3-Year Cure Rates

    PubMed Central

    Park, Yoo Jun

    2012-01-01

    Purpose Transobturator approaches to midurethral sling surgery are one of the most commonly performed operations for female stress urinary incontinence throughout the world. However, very few results of randomized clinical trials of transobturator midurethral sling surgery (MONARC vs. TVT-O) for the treatment of female urinary incontinence have been reported. In this study, we compared the 3-year follow-up cure rates of these two procedures. Materials and Methods From July 2006 to June 2008, 74 patients who had undergone MONARC (35 patients) or TVT-O (39 patients) were included in the study and were analyzed prospectively. The mean follow-up duration of both groups was 39.2 months. Preoperative and postoperative evaluations included physical examination, uroflowmetry and postvoid residual measurement, involuntary urine loss with physical activity, and urinary symptoms. Cure of female urinary incontinence was defined as patient report of no loss of urine upon physical activity. The patients' satisfaction after treatment was rated as very satisfied, satisfied, equivocal, and unsatisfied. Very satisfied and satisfied were considered as the satisfied rate. Results There were no significant differences in preoperative patient characteristics, postoperative complications, or success rate between the two groups. The cure rate of the MONARC and TVT-O groups was 85.7% and 84.6%, respectively. The patient satisfaction (very satisfied, satisfied) rate of the MONARC and TVT-O groups was 82.8% and 82.1%, respectively. Conclusions The MONARC and TVT-O procedures were equally efficient for the treatment of female urinary incontinence, with maintenance of high cure rates for 3 years. Longer follow-up is needed to confirm these results. PMID:22536469

  18. Retropubic versus transobturator tension-free vaginal tape (TVT vs TVT-O): Five-year results of the Austrian randomized trial.

    PubMed

    Tammaa, Ayman; Aigmüller, Thomas; Hanzal, Engelbert; Umek, Wolfgang; Kropshofer, Stephan; Lang, Peter F J; Ralph, George; Riss, Paul; Koelle, Dieter; Jundt, Katharina; Tamussino, Karl; Bjelic-Radisic, Vesna

    2018-01-01

    To compare outcomes of the retropubic versus the transobturator tension-free vaginal tape (TVT vs TVT-O) at 5 years. A total of 569 women undergoing surgery for primary stress incontinence were randomized to receive a retropubic or a transobturator tensionfree vaginal tape (TVT or TVT-O). Follow-up at 5 years included clinical examination, urodynamic studies and quality of life. The primary outcome measure was continence defined as a negative cough stress test at a volume of 300 mL. Secondary outcomes included urodynamic parameters, complications and quality of life.ClinicalTrials.gov (NCT 0041454). Three hundred and thirty-one patients (59%) were evaluated at 5 years (277 were seen, examined and completed questionnaires; 54 only completed questionnaires). No significant differences were seen in rates of a negative cough stress test (83% vs 76%, respectively), urodynamic parameters and complications. Quality-of-life improved significantly in both groups, without significant differences between the groups. Erosion rates were 5.2% and 4.5%, and reoperation rates were 4.1% and 3.2% respectively. At 5 years, subjective and objective results after TVT and TVT-O are stable and similar, without statistical significant differences between the procedures. Major long-term problems appear rare. © 2017 Wiley Periodicals, Inc.

  19. TVT ABBREVO: cadaveric study of tape position in foramen obturatum and adductor region.

    PubMed

    Hubka, Petr; Nanka, Ondrej; Masata, Jaromir; Martan, Alois; Svabik, Kamil

    2016-07-01

    The aim of the study was to describe fixation of the TVT ABBREVO and establish whether the tape penetrates through obturator muscles and membrane (obturator complex) into the adductor region and, if so, how far it penetrates. Eight formalin-embalmed female cadavers were used to simulate TVT ABBREVO surgery (totalling 16 insertions). Following tape insertion, dissection was performed and ends of the tape were identified. In cases of penetration, the length of tape penetrating into the adductor region was measured. Of the 16 cases, the tape ended in the obturator membrane in eight, in the internal obturator muscle in one, and penetrated through the obturator membrane into the external obturator muscle in five, where it remained. In two cases, it penetrated through the obturator internus muscle, obturator membrane and obturator externus muscle into the group of thigh adductors; one penetration was by 3 mm and the second by 10 mm. No contact with the obturator nerve or its branches was noted in any case. No TVT contact with the obturator nerve was noted; tape penetrated into the adductor region in two of the 16 cases.

  20. Efficacy of tension-free vaginal tape compared with transobturator tape in the treatment of stress urinary incontinence in women: analysis of learning curve, perioperative changes of voiding function

    PubMed Central

    2011-01-01

    Background In this study, by comparing TVT surgery and TOT surgery for stress urinary incontinence in women, the characteristics and learning curves of both operative methods were studied. Methods A total of 83 women with stress urinary incontinence treated with tension-free vaginal tape (TVT) (n = 38) or transobturator tape (TOT) (n = 45) at Saiseikai Central Hospital between April 2004 and September 2009 were included. We compare the outcomes and learning curves between TVT surgery and TOT surgery. In statistical analysis, Student's t test, Fisher's exact test, and Mann-Whitney's U test were used. Results The surgical durations were 37.4 ± 15.7 minutes with TVT surgery and 31.0 ± 8.3 minutes with TOT surgery. A longer period of time was required for TVT surgery (p = 0.025). The residual urine at post-operative day 1 was higher in TVT surgery (25.9 ± 44.2 ml) than in TOT surgery (10.6 ± 19.2 ml) (p = 0.0452). The surgical duration of TVT surgery was shortened after the operator had performed 15 operations (p = 0.019). Conclusions In comparison of TVT surgery and TOT surgery, the surgical duration of TVT surgery was longer and the residual urine of TVT surgery was higher at post-operative day 1. Surgical experience could shorten the duration of TVT surgery. PMID:21726448

  1. Comparing effectiveness of combined transobturator tension-free vaginal mesh (Perigee) and transobturator tension-free vaginal tape (TVT-O) versus anterior colporrhaphy and TVT-O for associated cystocele and urodynamic stress incontinence.

    PubMed

    Lau, Hei-Yu; Twu, Nae-Fang; Chen, Yi-Jen; Horng, Huann-Cheng; Juang, Chi-Mou; Chao, Kuan-Chong

    2011-06-01

    To evaluate the efficacy and safety of transobturator tension-free vaginal mesh (Perigee) and concomitant transobturator tension-free vaginal tape (TVT-O) for treating cystocele with urodynamic stress incontinence (UDSI). A retrospective study of 115 patients with symptomatic stages 2-3 cystocele and UDSI who were treated with a Perigee system (Group I, n=68) plus TVT-O procedure or traditional anterior colporrhaphy (Group II, n=47) plus TVT-O procedure. All patients were followed up for more than one year. Objective and subjective symptoms were evaluated at one year postoperatively. Statistical analysis was performed using SPSS software. The objective cure rates for cystocele at one year were significantly higher in Group I than in Group II (98.5% and 86.9%, P=0.018), respectively. The cure rates for UDSI in the two groups were 91.0% vs. 91.3% (P=1.000). Symptomatic improvement of frequency was better in Group I than Group II (87.7% vs. 70.0%, P=0.030). There were no significant differences with regard to intraoperative and postoperative complications between the two groups. The combination of the Perigee system and TVT-O offers a safe and effective treatment for cystocele with UDSI and may be performed as first-line treatment. Copyright © 2011 Elsevier Ireland Ltd. All rights reserved.

  2. Two new mini-slings compared with transobturator tension-free vaginal tape for treatment of stress urinary incontinence: A 1-year follow-up randomized controlled trial.

    PubMed

    Gaber, Mohamed E; Borg, Tamer; Samour, Hazem; Nawara, Mai; Reda, Ahmed

    2016-12-01

    The aim of this study was to compare the outcome of two single-incision mini-slings (the Contasure-Needleless [C-NDL] and the endopelvic free anchorage) with the standard midurethral transobturator tension-free vaginal tape (TVT-O) procedure. A double blind randomized controlled study was conducted at Ain Shams University Maternity Hospital from August 2014 until July 2015. A total of 209 patients were randomized into three groups. The first group underwent the TVT-O procedure, the second group underwent the endopelvic free anchorage procedure and the third group underwent the C-NDL procedure. Patients were followed up for 12 months in terms of subjective cure, objective cure, and complications rate. After 12 months of follow-up, there were no differences among the three groups in terms of objective cure rate, subjective cure rate, patient satisfaction, or incidence of complications (de novo urge, hemorrhage, infection, and mesh erosion). The C-NDL was associated with a shorter operative time (P < 0.001) and less blood loss (P = 0.021) than the standard TVT-O. The new single-incision mini-slings showed similar efficacy and patient acceptance to that of the standard TVT-O for up to 12 months postoperatively with no difference in the complications rate. The C-NDL is associated with shorter operative time and less blood loss. © 2016 Japan Society of Obstetrics and Gynecology.

  3. Outcome of the use of tension-free vaginal tape in women with mixed urinary incontinence, previous failed surgery, or low valsalva pressure.

    PubMed

    Abdel-Hady, El-Said; Constantine, Glyn

    2005-02-01

    To assess the safety and efficacy of the use of tension-free vaginal tape (TVT) for the treatment of stress urinary incontinence (SUI) in women with mixed incontinence, previous failed incontinence surgery or low valsalva leak point pressure (VLPP). Six hundred and fifty-eight women with SUI underwent the TVT procedure. These included women with mixed stress and urge incontinence (n=128), previous surgery for SUI (n=118), low VLPP (n=80), and those over 70 years old (n=68). The procedure was carried out under spinal anesthetic and operative and immediate postoperative data was collected for all women. Six-month follow-up data was available on 454 women, with the first 300 women completing a quality of life (QOL) questionnaire before and after surgery. The overall subjective cure rate at 6 months was 91%, with 8% of women reporting significant (>50%) improvement in their symptoms. Subgroups with a body mass index > 30, age > 70 years, coexisting instability, previous failed surgery, and low VLPP showed cure rates of 81-89%. QOL improvements for all groups were highly significant. Significant complications included voiding difficulties in 29 women (4.4%), retropubic hematomas in four (0.6%), and thromboembolic episodes in three (0.5%). The simplicity and high efficacy of the TVT makes it the first choice for the treatment of women with SUI, including those with more complex problems or coexisting risk factors.

  4. [Cases of strangulated obturator hernia].

    PubMed

    Chakhvadze, B; Nakashidze, D; Kashibadze, K; Beridze, A

    2010-02-01

    Obturator hernias are extremely rare in surgical practice. Only about 600 cases are described in the world medical literature. To diagnose obturator hernia is very complicated. Hernial protrusion is not often observed. The strangulation of obturator hernia is accompanied by rapidly developing symptoms of intestinal obstruction, which is usually an indication for emergency surgery. The article analyzes two clinical cases of strangulated obturator hernia and one traumatic eventration and strangulation of small intestine in the obturator ring ruined by trauma. In all cases the indication of surgery was clinical picture of a growing intestinal obstruction or acute abdomen. Only in one case, despite the prevailing clinical picture of acute intestinal obstruction in the light of anamnesis and the accompanying neurological symptoms before the operation could be suspected strangulated obturator hernia, which was confirmed during surgery. As it was mentioned above, in doubtful cases to clarify the diagnosis should be applied other methods of examination of patients, including computed tomography.

  5. The Efficiency and Safety of Tension-Free Vaginal Tape (TVT) Abbrevo Procedure Versus TVT Exact in the Normal Weight and Overweight Patients Affected by Stress Urinary Incontinence.

    PubMed

    Sun, Yi; Luo, Deyi; Yang, Lu; Wei, Xin; Tang, Cai; Chen, Mei; Shen, Hong; Wei, Qiang

    2017-12-01

    To compare the efficacy between 2 different slings in normal weight and overweight women. Of 426 women, 220 (119 normal weight and 101 overweight) accepted the tension-free vaginal tape Abbrevo (TVT-A) and 206 (114 normal weight and 92 overweight) accepted the TVT Exact (TVT-E) procedure. Data collected contained the subjective efficiency, objective efficiency International Consultation on Incontinence Questionnaire-Short Form (ICIQ-SF), Incontinence Quality of Life Questionnaire (I-QOL), Pelvic Floor Impact Questionnaire-Short Form (PFIQ-7), Urogenital Distress Inventory-Short Form (UDI-6), and Pelvic Organ Prolapse/Urinary Incontinence Sexual Questionnaire-Short Form (PISQ)-12 at 36 months after surgery. In the normal weight patients, the subjectively and objectively cured rates were all high in both TVT-A and TVE-E (94.12% and 95.61% in objective result; 92.44% and 94.74% in subjective result). In addition, the score of I-QOL, PFIQ-7, and UDI-6 have significantly changed (P <.00001 in each one). In the overweight patients, the subjective and objective efficiency were better in TVT-E than TVT-A. Moreover, the score of I-QOL, PFIQ-7, and UDI-6 of overweight women have significantly changed only in the TVT-E (P <.00001 in each one), whereas both procedures have no effect on the score of PISQ-12 (P = .063 and P = .180 for TVT-A and TVT-E, respectively). The TVT-E might be a better choice for the overweight patient than TVT-A. Copyright © 2017 Elsevier Inc. All rights reserved.

  6. Long-term clinical outcomes with the retropubic tension-free vaginal tape (TVT) procedure compared to Burch colposuspension for correcting stress urinary incontinence (SUI).

    PubMed

    Holdø, Bjørn; Verelst, Margareta; Svenningsen, Rune; Milsom, Ian; Skjeldestad, Finn Egil

    2017-11-01

    The retropubic tension-free vaginal tape (TVT) procedure replaced Burch colposuspension as the primary surgical method for stress urinary incontinence (SUI) and mixed urinary incontinence (MUI) in women in our department in 1998. In this study we compared the short-term and long-term clinical outcomes of these surgical procedures. Using a case series design, we compared the last 5 years of the Burch procedure (n = 127, 1994-1999) with the first 5 years of the retropubic TVT procedure (n = 180, 1998-2002). Information from the medical records was transferred to a case report form comprising data on perioperative and long-term complications as well as recurrence of UI, defined as bothersome UI or UI in need of repeat surgery. Other endpoints were rates of perioperative and late complications and the rates of prolapse surgery after primary surgery. The data were analyzed with the chi-squared and t tests and survival analysis using SPSS. The cumulative recurrence rate of SUI in women with preoperative SUI was significantly higher after the Burch procedure, but no difference was observed in women with MUI. There were no significant differences in rates of perioperative and late complications. At 12 years there was a significant increase in rates of repeat surgery for incontinence and prolapse in women after the Burch procedure. The long-term efficacy of TVT surgery was superior to that of Burch colposuspension in women with SUI. In addition, the rate of late prolapse surgery was significantly higher after the Burch procedure.

  7. Tension-free vaginal tape for treatment of pure urodynamic stress urinary incontinence: efficacy and adverse effects at 17-year follow-up.

    PubMed

    Braga, Andrea; Caccia, Giorgio; Sorice, Paola; Cantaluppi, Simona; Coluccia, Anna Chiara; Di Dedda, Maria Carmela; Regusci, Luca; Ghezzi, Fabio; Uccella, Stefano; Serati, Maurizio

    2018-07-01

    To assess the efficacy and safety of retropubic tension-free vaginal tape (TVT) 17 years after implantation for the treatment of female pure stress urinary incontinence (SUI). A prospective study was conducted in two urogynaecological units in two countries. All consecutive women with urodynamically proven pure SUI treated by TVT were included. Patients with mixed incontinence and/or anatomical evidence of pelvic organ prolapse were excluded. Data regarding subjective outcomes (International Consultation on Incontinence Questionnaire-Short Form, Patient Global Impression of Improvement, and patient satisfaction scores), objective cure (stress test) rates, and adverse events were collected during follow-up. Univariable analysis was performed to investigate outcomes. A total of 52 women underwent TVT implantation. At 17-year follow-up, 46 women (88.4%) were available for the evaluation. We did not find any significant change in surgical outcomes during this time. At 17 years after surgery, 41 of 46 women (89.1%) declared themselves cured (P = 0.98). Similarly, at 17-year evaluation, 42 of 46 women (91.4%) were objectively cured. No significant deterioration in objective cure rates was observed over time (P for trend 0.50). The univariate analysis did not find any risk factor statistically associated with the recurrence of SUI. Of the 46 women, 15 (32.6%) reported the onset of de novo overactive bladder at 17-year follow-up. No other late complications were reported. The 17-year results of this study showed that TVT is a highly effective and safe option for the treatment of SUI. © 2018 The Authors BJU International © 2018 BJU International Published by John Wiley & Sons Ltd.

  8. Function of obturator prosthesis after maxillectomy and prosthetic obturator rehabilitation.

    PubMed

    Chen, Cheng; Ren, Wenhao; Gao, Ling; Cheng, Zheng; Zhang, Linmei; Li, Shaoming; Zhi, Pro Ke-qian

    2016-01-01

    Maxillary defects are usually rehabilitated by a prosthetic obturator. This study aimed to evaluate the functioning of obturators prosthesis in patients with unilateral defects after maxillectomy. Of 49 patients, 28 underwent to maxillectomy as a result of tumor ablative surgery, and acquired unilateral maxillary defects. Evaluation of the function was performed by applying the Obturator Functional Scale (OFS). From a total of 49 patients, 28 were treated as follows: 9 with a conventional retained obturator prosthesis (COP), 11 (39%) with an enhanced retentive obturator prosthesis with stud attachment (POP) and 8 (28%) with an enhanced retentive obturator prosthesis with magnetic attachment (POM). The mean OFS score was 80. Scores on functions of speech, swallowing and chewing reached statistical significances (p<0.05) among these three subgroups. Comparing COP and MOP groups, the scores of OFS in the domains of "Speech-ability to speak in public" and "Swallowing-leakage with liquids" were significantly higher in AOP group. Comparing COP group, the scores of OFS in "Swallowing-leakage with solid" and "Chewing/eating" domains were increased significantly (p<0.05) both in MOP and AOP groups. Obturator prosthesis improves oral function of patients after maxillary defects; the retention of the obturator prosthesis enhanced by the addition of attachments showed more benefits in oral function. Copyright © 2015 Associação Brasileira de Otorrinolaringologia e Cirurgia Cérvico-Facial. Published by Elsevier Editora Ltda. All rights reserved.

  9. Single incision device (TVT Secur) versus retropubic tension-free vaginal tape device (TVT) for the management of stress urinary incontinence in women: a randomized clinical trial.

    PubMed

    Ross, Sue; Tang, Selphee; Schulz, Jane; Murphy, Magnus; Goncalves, Jose; Kaye, Stephen; Dederer, Lorel; Robert, Magali

    2014-12-22

    In 2006, Ethicon Inc. introduced a new minimally invasive single incision sling device for the surgical treatment of stress urinary incontinence, the Gynecare TVT Secur®. For device licensing, no new evidence of TVT Secur efficacy and safety was needed: rather evidence was provided of the long-term follow-up of patients who had a procedure using a predecate retropubic tension-free vaginal tape device. Before adopting TVT Secur into our routine clinical practice, we decided to evaluate it. The objective of our Canadian multi-centre pragmatic randomized controlled trial was to compare the effectiveness of the new single-incision device, TVT Secur, to the established TVT device, in terms of objective cure of stress urinary incontinence (SUI) at 12 months postoperatively. Other outcomes included: complications, symptoms, and incontinence-related quality of life. The sample size estimate for our trial was 300, but the trial stopped early because of poor recruitment. 74 women participated (40 allocated to TVT Secur, 34 to TVT). At 12 months postoperatively, 27/33(82%) of TVT Secur group were cured, compared with 25/28(89%) of the TVT group (relative risk 0.92, 95% confidence interval 0.75 to 1.13, p=0.49). Most women reported little or no SUI symptoms (35/37(95%) vs 29/30(97%), >0.999). Quality of life improved significantly from baseline for both groups (IIQ-7 mean change -25 for both groups) but did not differ between groups (p=0.880). Our small randomized trial did not find statistically significant differences in outcomes between women allocated to the TVT Secur device versus those allocated to the TVT device for stress urinary incontinence. Despite the discontinuation of TVT Secur in March 2013 for commercial reasons, the importance of our study lies in making evidence available for the many women who had a TVT Secur device implanted and their physicians who may be considering alternative treatments. Our experience illustrates the difficulty of undertaking research

  10. Obturator hernia: A diagnostic challenge.

    PubMed

    Kulkarni, Sanjeev R; Punamiya, Aditya R; Naniwadekar, Ramchandra G; Janugade, Hemant B; Chotai, Tejas D; Vimal Singh, T; Natchair, Arafath

    2013-01-01

    Obturator hernia is an extremely rare type of hernia with relatively high mortality and morbidity. Its early diagnosis is challenging since the signs and symptoms are non specific. Here in we present a case of 70 years old women who presented with complaints of intermittent colicky abdominal pain and vomiting. Plain radiograph of abdomen showed acute dilatation of stomach. Ultrasonography showed small bowel obstruction at the mid ileal level with evidence of coiled loops of ileum in pelvis. On exploration, Right Obstructed Obturator hernia was found. The obstructed Intestine was reduced and resected and the obturator foramen was closed with simple sutures. Postoperative period was uneventful. Obturator hernia is a rare pelvic hernia and poses a diagnostic challenge. Obturator hernia occurs when there is protrusion of intra-abdominal contents through the obturator foramen in the pelvis. The signs and symptoms are non specific and generally the diagnosis is made during exploration for the intestinal obstruction, one of the four cardinal features. Others are pain on the medial aspect of thigh called as Howship Rombergs sign, repeated attacks of Intestinal Obstruction and palpable mass on the medial aspect of thigh. Obturator hernia is a rare but significant cause of intestinal obstruction especially in emaciated elderly woman and a diagnostic challenge for the Doctors. CT scan is valuable to establish preoperative diagnosis. Surgery either open or laproscopic, is the only treatment. The need for the awareness is stressed and CT scan can be helpful. Copyright © 2013 Surgical Associates Ltd. Published by Elsevier Ltd. All rights reserved.

  11. Vaginal cancer

    MedlinePlus

    Vaginal cancer; Cancer - vagina; Tumor - vaginal ... Most vaginal cancers occur when another cancer, such as cervical or endometrial cancer , spreads. This is called secondary vaginal cancer. Cancer ...

  12. Anatomy of the obturator region: relations to a trans-obturator sling.

    PubMed

    Whiteside, James L; Walters, Mark D

    2004-01-01

    Our objective was to determine the relationships between a trans-obturator sling and anatomic structures within the obturator region. The obturator regions of six cadavers were dissected and distances from the mid-point of the ischiopubic ramus to the muscles, nerves, and vessels of the region were measured. A trans-obturator sling was placed and distances from the device to the same anatomic structures were determined. Four additional cadavers were dissected to determine the device route of passage. The obturator canal is on average 4.4 cm from the midpoint of the ischiopubic rami. The trans-obturator sling passes on average 2.4 cm inferior-medial to the obturator canal. The anterior and posterior divisions of the obturator nerve are on average 3.4 and 2.8 cm, respectively, from a passed trans-obturator device. The device passed on average 1.1 cm from the most medial branch of the obturator vessels. Vascular and nerve structures are within 1-3 cm of the path of any device passed through the obturator foramen. A trans-obturator sling risks injury to these structures, although the small caliber of the vessels and the confined space in which they would bleed make the consequences of injury uncertain.

  13. Vaginal Atrophy

    MedlinePlus

    ... an Endocrinologist Search Featured Resource Menopause Map™ View Vaginal Atrophy October 2017 Download PDFs English Editors Christine ... during this time, including vaginal dryness. What is vaginal atrophy? Vaginal atrophy (also referred to as vulvovaginal ...

  14. Are the same tapes really the same? Ultrasound study of laser-cut and mechanically cut TVT-O post-operative behavior.

    PubMed

    Rusavy, Zdenek; Masata, Jaromir; Svabik, Kamil; Hubka, Petr; Zvara, Karel; Martan, Alois

    2017-11-25

    TVT-O production has been modified to laser cutting from mechanical cutting. We compared the behavior of laser and mechanically cut tension-free vaginal tape-obturator (TVT-O) using ultrasound at various time points after surgery. This is a retrospective analysis of clinical and ultrasound data from two previously reported randomized controlled trials with TVT-O. Behavior of mechanically cut TVT-O implanted in January 2007 to November 2009 and laser-cut TVT-O implanted in May 2010 to May 2012 was assessed by ultrasound at day 1, the 2nd week, the 3rd month, and the 1st and 2nd years post-operatively. Bladder neck and tape margins positions were described by coordinates in the orthogonal system calculated from polar coordinates. Tape mobility was measured as a change in the upper and lower tape margin position from rest to maximal Valsalva. Comparison of 2-year subjective and objective surgery outcomes was also performed. In total, 68 mechanically cut and 50 laser-cut TVT-Os were implanted. Follow-up data were available from 49 and 45 women respectively. No differences in any baseline characteristics or bladder neck mobility were observed. Significantly lower tape mobility was observed on day 1 and week 2 after mechanically cut TVT-O, although subsequent mobility was comparable to laser-cut TVT-O. The subjective and objective surgery outcomes were comparable. Although without clinical significance, early postoperative behavior of the mechanically cut and laser-cut TVT-O tapes differs. The less stiff, mechanically-cut TVT-O loosens within 2 weeks of implantation, whereas the stiffer, laser-cut TVT-O keeps its tension.

  15. Industrial Tape

    NASA Technical Reports Server (NTRS)

    1986-01-01

    Scotch Brand Tape 364 was developed for NASA by 3M Company to protect electrical instrumentation coils and fluid lines from rocket launch blast conditions. It is an aluminized glass cloth tape which can withstand very high temperatures, is easily applied to compound surfaces, has excellent solar energy reflectance, and does not present an electrostatic hazard. It has potential automotive, transportation, and building construction applications.

  16. Palatal obturators in patients after maxillectomy.

    PubMed

    Cardelli, P; Bigelli, E; Vertucci, V; Balestra, F; Montani, M; DE Carli, S; Arcuri, C

    2014-01-01

    Prosthodontic management of palatal defects is fundamental to improve patient's life undergoing to a maxillary surgical treatment. A lot of maxillary defects are a direct consequence of surgical treatment of malformations, neoplasms or trauma. The obturators are prosthesis used to close palatal defects after maxillectomy, to restore masticatory function and to improve speech. The primary goals of the obturator prosthesis are to preserve the remaining teeth and tissue and to provide comfort, function, and aesthetics to the patients. Different materials and retention methods are a characteristic of new types of obturators.

  17. Palatal obturators in patients after maxillectomy

    PubMed Central

    CARDELLI, P.; BIGELLI, E.; VERTUCCI, V.; BALESTRA, F.; MONTANI, M.; DE CARLI, S.; ARCURI, C.

    2014-01-01

    SUMMARY Prosthodontic management of palatal defects is fundamental to improve patient’s life undergoing to a maxillary surgical treatment. A lot of maxillary defects are a direct consequence of surgical treatment of malformations, neoplasms or trauma. The obturators are prosthesis used to close palatal defects after maxillectomy, to restore masticatory function and to improve speech. The primary goals of the obturator prosthesis are to preserve the remaining teeth and tissue and to provide comfort, function, and aesthetics to the patients. Different materials and retention methods are a characteristic of new types of obturators. PMID:25992263

  18. 21 CFR 868.5650 - Esophageal obturator.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ...) Identification. An esophageal obturator is a device inserted through a patient's mouth to aid ventilation of the patient during emergency resuscitation by occluding (blocking) the esophagus, thereby permitting positive...

  19. SPEECH EVALUATION WITH AND WITHOUT PALATAL OBTURATOR IN PATIENTS SUBMITTED TO MAXILLECTOMY

    PubMed Central

    de Carvalho-Teles, Viviane; Pegoraro-Krook, Maria Inês; Lauris, José Roberto Pereira

    2006-01-01

    Most patients who have undergone resection of the maxillae due to benign or malignant tumors in the palatomaxillary region present with speech and swallowing disorders. Coupling of the oral and nasal cavities increases nasal resonance, resulting in hypernasality and unintelligible speech. Prosthodontic rehabilitation of maxillary resections with effective separation of the oral and nasal cavities can improve speech and esthetics, and assist the psychosocial adjustment of the patient as well. The objective of this study was to evaluate the efficacy of the palatal obturator prosthesis on speech intelligibility and resonance of 23 patients with age ranging from 18 to 83 years (Mean = 49.5 years), who had undergone inframedial-structural maxillectomy. The patients were requested to count from 1 to 20, to repeat 21 words and to spontaneously speak for 15 seconds, once with and again without the prosthesis, for tape recording purposes. The resonance and speech intelligibility were judged by 5 speech language pathologists from the tape recordings samples. The results have shown that the majority of patients (82.6%) significantly improved their speech intelligibility, and 16 patients (69.9%) exhibited a significant hypernasality reduction with the obturator in place. The results of this study indicated that maxillary obturator prosthesis was efficient to improve the speech intelligibility and resonance in patients who had undergone maxillectomy. PMID:19089242

  20. Magnetic tape

    NASA Technical Reports Server (NTRS)

    Robinson, Harriss

    1992-01-01

    The move to visualization and image processing in data systems is increasing the demand for larger and faster mass storage systems. The technology of choice is magnetic tape. This paper briefly reviews the technology past, present, and projected. A case is made for standards and the value of the standards to users.

  1. Vaginal Atrophy

    MedlinePlus

    ... syndrome of menopause (GSM) increases your risk of: Vaginal infections. Changes in the acid balance of your vagina makes vaginal infections (vaginitis) more likely. Urinary problems. Urinary changes associated ...

  2. Vaginal mucosal flap as a sling preservation for the treatment of vaginal exposure of mesh.

    PubMed

    Kim, Sea Young; Park, Jong Yeon; Kim, Han Kwon; Park, Chang Hoo; Kim, Sung Jin; Sung, Gi Teck; Park, Chang Myon

    2010-06-01

    Tension-free vaginal tape (TVT) procedures are used for the treatment of stress urinary incontinence in women. The procedures with synthetic materials can have a risk of vaginal erosion. We experienced transobturator suburethral sling (TOT) tape-induced vaginal erosion and report the efficacy of a vaginal mucosal covering technique. A total of 560 female patients diagnosed with stress urinary incontinence underwent TOT procedures at our hospital between January 2005 and August 2009. All patients succeeded in follow-ups, among which 8 patients (mean age: 50.5 years) presented with vaginal exposure of the mesh. A vaginal mucosal covering technique was performed under local anesthesia after administration of antibiotics and vaginal wound dressings for 3-4 days. Seven of the 8 patients complained of persistent vaginal discharge postoperatively. Two of the 8 patients complained of dyspareunia of their male partners. The one remaining patient was otherwise asymptomatic, but mesh erosion was discovered at the routine follow-up visit. Six of the 8 patients showed complete mucosal covering of the mesh after the operation (mean follow-up period: 16 moths). Vaginal mucosal erosion recurred in 2 patients, and the mesh was then partially removed. One patient had recurrent stress urinary incontinence. Vaginal mucosal covering as a sling preservation with continued patient continence may be a feasible and effective option for the treatment of vaginal exposure of mesh after TOT tape procedures.

  3. Urinary incontinence - tension-free vaginal tape

    MedlinePlus

    ... after surgery or the next morning if you stay overnight. You may go home on the same day if there are no problems. Follow instructions about how to care for yourself after you go home. Keep all follow-up appointments.

  4. Sealing maxillary titanium obturators with removable flexible caps.

    PubMed

    Reitemeier, Bernd; Schaal, Wolfgang; Wolf, Annette; Walter, Michael

    2016-03-01

    Maxillary obturator prostheses with hollow metal obturators can be made of titanium to reduce weight. To prevent perforation of the hollow obturator during modifications, the obturator is slightly undersized and covered with a replaceable cap. This cap is made of a soft copolymer to facilitate uncomplicated modifications in the resection area and to improve function. Copyright © 2016 Editorial Council for the Journal of Prosthetic Dentistry. Published by Elsevier Inc. All rights reserved.

  5. Vaginal disorders.

    PubMed

    Soderberg, S F

    1986-05-01

    Chronic vaginitis is the most common vaginal disorder. Dogs with vaginitis show no signs of systemic illness but often lick at the vulva and have purulent or hemorrhagic vaginal discharges. Vaginitis is most commonly secondary to a noninfectious inciting factor such as congenital vaginal anomalies, clitoral hypertrophy, foreign bodies, trauma to the vaginal mucosa, or vaginal tumors. Inspection of the caudal vagina and vestibule both visually and digitally will often reveal the source of vaginal irritation. Vaginal cytology is used to establish the stage of the estrous cycle as well as distinguish uterine from vaginal sources of discharge. Vaginal cultures are used to establish the predominant offending organism associated with vaginal discharges and may be used as a guide for selection of a therapeutic agent. Vaginitis is best managed by removing the inciting cause and treating the area locally with antiseptic douches. Congenital malformations at the vestibulovaginal or vestibulovulvar junction may prevent normal intromission. Affected bitches may be reluctant to breed naturally because of pain. Such defects are detected best by digital examination. Congenital vaginal defects may be corrected by digital or surgical means. Prolapse of tissue through the lips of the vulva may be caused by clitoral hypertrophy, vaginal hyperplasia, or vaginal tumors. Enlargement of clitoral tissue is the result of endogenous or exogenous sources of androgens. Treatment of this condition includes removal of the androgen source and/or surgical removal of clitoral tissue. Vaginal hyperplasia is detected during proestrus or estrus of young bitches. Hyperplastic tissue will regress during diestrus. Tissue that is excessively traumatized and/or prolapse of the entire vaginal circumference may be removed surgically. Ovariohysterectomy may be used to prevent recurrence. Vaginal tumors are detected most often in older intact bitches. Such tumors are generally of smooth muscle or fibrous

  6. Comparative evaluation of fracture resistance of root canals obturated with four different obturating systems

    PubMed Central

    Punjabi, Mansi; Dewan, Ruchika Gupta; Kochhar, Rohit

    2017-01-01

    Aim and Objectives: The aim of this study is to evaluate and compare the fracture resistance of root canals obturated with four different obturating systems in endodontically treated teeth. Materials and Methods: One hundred and twenty single-rooted teeth were selected and decoronated at cementoenamel junction. Instrumentation of teeth (except control group) was done with Mtwo rotary files up to size 25/0.06 using a step-back technique. All teeth were divided into four experimental groups (n = 25) and two control groups (n = 10). In Group I (negative control), teeth were neither instrumented nor obturated, in Group II (positive control), instrumentation was done, but no obturation was performed, in Group III, obturation was done with cold lateral compaction technique, in Group IV, obturation was done with cold free-flow compaction technique, in Group V, obturation was done with warm vertical compaction technique, and in Group VI, obturation was done with injection-molded thermoplasticized technique. All prepared teeth were embedded in an acrylic resin block, and their fracture strength was measured using Universal Testing Machine. Statistical data were analyzed using one-way analysis of variance and Tukey's honestly significant difference test. Results: Negative control Group I showed highest fracture resistance and positive control Group II had lowest fracture resistance. Among experimental groups, cold free-flow compaction technique with GuttaFlow2 (Group IV) showed higher fracture resistance as compared to the Group III, Group V, and Group VI. Conclusion: GuttaFlow2 has the potential to strengthen the endodontically treated roots to a level that is similar to that of intact teeth. PMID:29430099

  7. Comparative evaluation of fracture resistance of root canals obturated with four different obturating systems.

    PubMed

    Punjabi, Mansi; Dewan, Ruchika Gupta; Kochhar, Rohit

    2017-01-01

    The aim of this study is to evaluate and compare the fracture resistance of root canals obturated with four different obturating systems in endodontically treated teeth. One hundred and twenty single-rooted teeth were selected and decoronated at cementoenamel junction. Instrumentation of teeth (except control group) was done with Mtwo rotary files up to size 25/0.06 using a step-back technique. All teeth were divided into four experimental groups ( n = 25) and two control groups ( n = 10). In Group I (negative control), teeth were neither instrumented nor obturated, in Group II (positive control), instrumentation was done, but no obturation was performed, in Group III, obturation was done with cold lateral compaction technique, in Group IV, obturation was done with cold free-flow compaction technique, in Group V, obturation was done with warm vertical compaction technique, and in Group VI, obturation was done with injection-molded thermoplasticized technique. All prepared teeth were embedded in an acrylic resin block, and their fracture strength was measured using Universal Testing Machine. Statistical data were analyzed using one-way analysis of variance and Tukey's honestly significant difference test. Negative control Group I showed highest fracture resistance and positive control Group II had lowest fracture resistance. Among experimental groups, cold free-flow compaction technique with GuttaFlow2 (Group IV) showed higher fracture resistance as compared to the Group III, Group V, and Group VI. GuttaFlow2 has the potential to strengthen the endodontically treated roots to a level that is similar to that of intact teeth.

  8. Predictors of obturator functioning and satisfaction in Turkish patients using an obturator prosthesis after maxillectomy.

    PubMed

    Ozdemir-Karatas, Meltem; Balik, Ali; Evlioglu, Gülümser; Uysal, Ömer; Peker, Kadriye

    2018-03-01

    The aim of this study was to determine the sociodemographic, behavioral, and clinical factors affecting obturator function and satisfaction using the obturator functioning scale (OFS) in maxillectomy patients rehabilitated with obturator prostheses. The study sample consisted of 41 maxillectomy patients. The OFS was translated into Turkish and adapted for assessing obturator functioning and patient satisfaction among Turkish patients. Data were collected from patients' medical records and self-completed questionnaires, including the Turkish version of the OFS, sociodemographic and behavioral characteristics. Descriptive statistics, Mann-Whitney U test, Spearman's correlation coefficient, and backward stepwise multiple linear regression were used for data analysis. Internal consistency (Cronbach's alpha = 0.85) and test-retest reliability (intraclass correlation coefficient = 0.86) were acceptable for the OFS. The most frequently reported problem was "difficulty chewing." Bivariate analysis revealed significant differences in total OFS scores in terms of surgery type, defect size, and education level, except for the other clinical and sociodemographic characteristics and behavioral factors. Education level and surgery type were found to be the most important predictors of patient satisfaction and functioning of the obturator. The Turkish version of the OFS might be a useful tool for clinicians to identify patients who are at risk for poor functioning of the obturator, lack of satisfaction, and unmet needs. Copyright © 2017 Elsevier Inc. All rights reserved.

  9. Vaginal Bleeding

    MedlinePlus

    ... bleeding is any vaginal bleeding unrelated to normal menstruation. This type of bleeding may include spotting of ... two or more hours. Normal vaginal bleeding, or menstruation, occurs every 21 to 35 days when the ...

  10. Vaginal Odor

    MedlinePlus

    ... usually don't cause vaginal odors. Neither do yeast infections. Generally, if you have vaginal odor without ... Avoid douching. All healthy vaginas contain bacteria and yeast. The normal acidity of your vagina keeps bacteria ...

  11. Clindamycin Vaginal

    MedlinePlus

    ... an infection caused by an overgrowth of harmful bacteria in the vagina). Clindamycin is in a class ... works by slowing or stopping the growth of bacteria. Vaginal clindamycin cannot be used to treat vaginal ...

  12. Vaginal Diseases

    MedlinePlus

    Vaginal problems are some of the most common reasons women go to the doctor. They may have ... common problem is vaginitis, an inflammation of the vagina. Other problems that affect the vagina include sexually ...

  13. Vaginal cysts

    MedlinePlus

    ... essential to determine what type of cyst or mass you may have. A mass or bulge of the vaginal wall may be ... to rule out vaginal cancer, especially if the mass appears to be solid. If the cyst is ...

  14. Tape transport mechanism

    DOEpatents

    Groh, Edward F.; McDowell, William; Modjeski, Norbert S.; Keefe, Donald J.; Groer, Peter

    1979-01-01

    A device is provided for transporting, in a stepwise manner, tape between a feed reel and takeup reel. An indexer moves across the normal path of the tape displacing it while the tape on the takeup reel side of the indexer is braked. After displacement, the takeup reel takes up the displaced tape while the tape on the feed reel side of the indexer is braked, providing stepwise tape transport in precise intervals determined by the amount of displacement caused by the indexer.

  15. The safety and efficacy of the "inside-out" trans-obturator TVT in elderly versus younger stress-incontinent women: a prospective study of 353 consecutive patients.

    PubMed

    Groutz, Asnat; Cohen, Aviad; Gold, Ronen; Pauzner, David; Lessing, Joseph B; Gordon, David

    2011-03-01

    To analyze the safety and efficacy of the trans-obturator tension-free vaginal tape (TVT-O) in elderly versus younger stress-incontinent women. Ninety-seven consecutive elderly, aged 70 and older, and 256 younger women (mean age 75 and 55 years, respectively) who underwent TVT-O for urodynamically confirmed stress urinary incontinence (SUI) were prospectively enrolled. Concomitant pelvic organ prolapse (POP) repair was performed in 90% of the elderly and 70% of the younger women. The surgical procedures, as well as all pre- and postoperative clinical and urodynamic evaluation, were performed in one university-affiliated medical center. Main outcome measures were operative complications, early and late postoperative morbidity, postoperative urodynamically confirmed SUI (symptomatic, or asymptomatic), persistent, or de novo overactive bladder (OAB) and bladder outlet obstruction (BOO). Mean follow-up of the patients was 30 ± 17 months (range 3-58 months). Early and late postoperative morbidity was similar in both groups, except for significantly more cases of postoperative recurrent UTI's among elderly women (13.7% vs. 6.2%). The incidence of persistent urodynamically confirmed overt SUI was similar in both age groups (5%). However, asymptomatic urodynamic SUI was significantly more common among elderly patients (19% vs. 3.7%, P<0.05). The incidence of persistent OAB was similar in elderly and younger patients (68% and 62%, respectively), while de novo OAB was significantly more common in elderly patients (11.9% vs. 4.7%, P<0.05). TVT-O is safe and efficient for both elderly and younger stress-incontinent women. However, elderly patients are in increased risk for postoperative recurrent UTI's as well as de novo OAB. Copyright © 2010 Wiley-Liss, Inc.

  16. Tape functionality: sonographic tape characteristics and outcome after TVT incontinence surgery.

    PubMed

    Kociszewski, Jacek; Rautenberg, Oliver; Perucchini, Daniele; Eberhard, Jakob; Geissbühler, Verena; Hilgers, Reinhard; Viereck, Volker

    2008-01-01

    To investigate tension-free vaginal tape (TVT) position and shape using ultrasound (US) and correlate the findings to outcome. The results of TVT surgery were investigated in 72 women with urodynamic stress urinary incontinence. The main outcome parameters were US tape position in relation to the urethra and dynamic changes in TVT shape at rest and during straining. Sixty-two patients (86%) were continent, 6 (8%) significantly improved, and the operation failed in four cases (6%). The median tape position was at 66% of the urethral length measured by US. The median tape-urethra-lumen distance was 3.8 mm at rest. Tape placement in the upper or lower quarter of the urethra was associated with a higher failure rate. Tapes positioned less than 3 mm from the urethra significantly increased postoperative complications (P < 0.0001). The tape was flat at rest and curved during straining in 44 (61%) patients; 98% (43/44) of these women were continent after surgery. An unchanged tape shape was associated with a poorer outcome (P = 0.00038). Patients with a flat tape at rest and during straining failed in 25% and patients with a permanent curved shape in 10%. TVT position relative to the patient's urethra seems to play a role in treatment outcome. Outcome was best in patients with dynamic change in tape shape during straining and location of the tape at the junction between the lower and middle urethra and at least 3 mm from the urethral lumen. (c) 2008 Wiley-Liss, Inc.

  17. Vaginal Cancer

    MedlinePlus

    Vaginal cancer is a rare type of cancer. It is more common in women 60 and older. You are also more likely to get it if you have had a human ... test can find abnormal cells that may be cancer. Vaginal cancer can often be cured in its ...

  18. Vaginal Fistula

    MedlinePlus

    Vaginal fistula Overview A vaginal fistula is an abnormal opening that connects your vagina to another organ, such as your bladder, colon or rectum. Your ... describe the condition as a hole in your vagina that allows stool or urine to pass through ...

  19. Obturator Hernia: A Rare Case of Acute Mechanical Intestinal Obstruction

    PubMed Central

    Yucel, Ahmet Fikret; Pergel, Ahmet; Sahin, Dursun Ali

    2013-01-01

    Obturator hernia is a rare type of pelvic hernia which generally occurs in elderly patients with accompanying diseases. Because it is difficult to diagnose before surgery, the morbidity and mortality rates for obturator hernia are high. The most common symptom is strangulation combined with mechanical intestinal obstruction. PMID:23738179

  20. Obturator hernia: a rare case of acute mechanical intestinal obstruction.

    PubMed

    Aydin, Ibrahim; Yucel, Ahmet Fikret; Pergel, Ahmet; Sahin, Dursun Ali

    2013-01-01

    Obturator hernia is a rare type of pelvic hernia which generally occurs in elderly patients with accompanying diseases. Because it is difficult to diagnose before surgery, the morbidity and mortality rates for obturator hernia are high. The most common symptom is strangulation combined with mechanical intestinal obstruction.

  1. Magnetic tape user guide

    NASA Technical Reports Server (NTRS)

    Evans, A. B.; Lee, L. L.

    1985-01-01

    This User Guide provides a general introduction to the structure, use, and handling of magnetic tapes at Langley Research Center (LaRC). The topics covered are tape terminology, physical characteristics, error prevention and detection, and creating, using, and maintaining tapes. Supplementary documentation is referenced where it might be helpful. The documentation is included for the tape utility programs, BLOCK, UNBLOCK, and TAPEDMP, which are available at the Central Scientific Computing Complex at LaRC.

  2. Tape reading fixture

    NASA Technical Reports Server (NTRS)

    1969-01-01

    Commercially available roller type desk pad provides an efficient and orderly manner of handling rolled paper tapes for proofreading. The fixture, which is modified to accept Flex-O-Writer or similar tapes and roll them in either direction, reduces the chance of damaging or soiling the tapes through repeated handling.

  3. Emphysematous vaginitis.

    PubMed

    Lima-Silva, Joana; Vieira-Baptista, Pedro; Cavaco-Gomes, João; Maia, Tiago; Beires, Jorge

    2015-04-01

    Emphysematous vaginitis is a rare condition, characterized by the presence of multiple gas-filled cysts in the vaginal and/or exocervical mucosa. Although its etiology is not completely understood, it is self-limited, with a benign clinical course. Vaginal discharge, sometimes bloody, and pruritus are the most common symptoms. Chronic and acute inflammation can be found, and diseases that impair the immune system and pregnancy have been associated with this condition. A 48-year-old postmenopausal woman, with a history of hysterectomy with several comorbidities, presented with a 4-month history of bloody discharge and vulvar pruritus. Examination showed multiple cystic lesions, 1 to 5 mm, occupying the posterior and right lateral vaginal walls. Speculum examination produced crepitus. Vaginal wet mount was normal, except for diminished lactobacilli; results of Trichomonas vaginalis DNA test and vaginal cultures were negative. Lugol's iodine applied to the vagina was taken up by the intact lesions. Biopsy result showed typical features of emphysematous vaginitis. This is an unusual entity, presenting with common gynecological complaints, and both physicians and pathologists should be aware to prevent misdiagnosis and overtreatment.

  4. Metronidazole Vaginal

    MedlinePlus

    ... is used to treat vaginal infections such as bacterial vaginosis (an infection caused from too much of certain bacteria in the vagina). Metronidazole is in a class of medications called nitroimidazole antimicrobials. It works by stopping the growth of bacteria.

  5. Vaginal bleeding

    MedlinePlus

    ... who are approaching menopause. Women who take oral contraceptives may experience episodes of abnormal vaginal bleeding. Often ... Practice Bulletin No. 110: noncontraceptive uses of hormonal contraceptives. Obstet Gynecol . 2010;115(1):206-218. PMID: ...

  6. Vaginal Discharge

    MedlinePlus

    ... also be on the lookout for symptoms of yeast infections, bacterial vaginosis and trichomoniasis, 3 infections that ... cause changes in your vaginal discharge. Signs of yeast infections White, cottage cheese-like discharge Swelling and ...

  7. Estrogen Vaginal

    MedlinePlus

    ... estradiol vaginal ring is also used to treat hot flushes ('hot flashes'; sudden strong feelings of heat and sweating) ... leave the ring in place when you have sex. If you choose to remove it or if ...

  8. Quality of life in patients with obturator prostheses.

    PubMed

    Riaz, Nabeela; Warriach, Riaz Ahmad

    2010-01-01

    Oral cancer has a profound impact on the quality of life for patients and their families. Functionally, the mouth is an important organ for speech, swallowing, chewing, taste and salivation. These functions become compromised due to surgical ablation of the tumour. Obturator prosthesis is a common prosthdontic rehabilitative option for maxillectomy patients. The purpose of this study was to investigate how patients with maxillofacial defects evaluate their quality of life after maxillectomy and prosthodontic therapy with obturator prostheses. Thirty patients were included in the study (11 female, 19 male). The patients were interviewed by using a standardised questionnaire developed by University of Washington (UW-QOL). The detailed questionnaire was adjusted for obturator patients and internalised most parts of obturator functioning scale (OFS). Quality of life after prosthodontic therapy with obturator prostheses was 54 +/- 22.9% on average. Functioning of the obturator prosthesis, impairment of ingestion, speech and appearance, the extent of therapy, and the existence of pain had significant impact on the quality of life (p<0.005). Orofacial rehabilitation of patients with maxillofacial defects using obturator prostheses is an appropriate treatment modality. To improve the situation of patients prior to and after maxillectomy sufficient information about the treatment, adequate psychological care and speech therapy should be provided.

  9. Injuries of the obturator muscles in professional soccer players.

    PubMed

    Wong-On, Manuel; Turmo-Garuz, Antonio; Arriaza, Rafael; Gonzalez de Suso, Jose Manuel; Til-Perez, Luis; Yanguas-Leite, Xavier; Diaz-Cueli, David; Gasol-Santa, Xavier

    2017-02-10

    Obturator externus and internus muscular tears are uncommon injuries. Only a few case reports exist, mainly in high-level athletes. Our aim is to describe a series of obturator externus and internus muscular tears in professional soccer players. Injury data from four teams from the First Division of the Spanish Soccer League were collected over a total of four seasons. Any soccer player who sustained an injury to either the obturator externus or internus identified on magnetic resonance (MRI) was included. All injured players were treated non-operatively with a goal of returning to play as fast as possible. Sixteen players sustained injuries to the obturator externus and internus during matches or training sessions. The main complaint was anterior hip pain with a physical examination showing pain during internal rotation or external rotation of the flexed hip. The MRI documented 12 muscular tears of the obturator externus, and 4 muscular tears of the obturator internus. All injuries were treated conservatively based on physical therapy, analgesic medications, and underwent a symptoms-based rehabilitation protocol. Mean return to play was 11.5  ±  8.8 days. Although uncommon, tears of the obturator externus and internus occur in professional soccer players. The MRI scan was essential to the location, classification, and evaluation of the injury size. The clinical relevance of our investigation is based on the relatively benign prognosis of these injuries. IV.

  10. Vaginal Microbiota.

    PubMed

    Mendling, Werner

    2016-01-01

    The knowledge about the normal and abnormal vaginal microbiome has changed over the last years. Culturing techniques are not suitable any more for determination of a normal or abnormal vaginal microbiota. Non culture-based modern technologies revealed a complex and dynamic system mainly dominated by lactobacilli.The normal and the abnormal vaginal microbiota are complex ecosystems of more than 200 bacterial species influenced by genes, ethnic background and environmental and behavioral factors. Several species of lactobacilli per individuum dominate the healthy vagina. They support a defense system together with antibacterial substances, cytokines, defensins and others against dysbiosis, infections and care for an normal pregnancy without preterm birth.The numbers of Lactobacillus (L.) iners increase in the case of dysbiosis.Bacterial vaginosis (BV) - associated bacteria (BVAB), Atopobium vaginae and Clostridiales and one or two of four Gardnerella vaginalis - strains develop in different mixtures and numbers polymicrobial biofilms on the vaginal epithelium, which are not dissolved by antibiotic therapies according to guidelines and, thus, provoke recurrences.Aerobic vaginitis seems to be an immunological disorder of the vagina with influence on the microbiota, which is here dominated by aerobic bacteria (Streptococcus agalactiae, Escherichia coli). Their role in AV is unknown.Vaginal or oral application of lactobacilli is obviously able to improve therapeutic results of BV and dysbiosis.

  11. Hysterectomy - vaginal - discharge

    MedlinePlus

    Vaginal hysterectomy - discharge; Laparoscopically assisted vaginal hysterectomy - discharge; LAVH - discharge ... you were in the hospital, you had a vaginal hysterectomy. Your surgeon made a cut in your ...

  12. Thermoplastic tape compaction device

    DOEpatents

    Campbell, V.W.

    1994-12-27

    A device is disclosed for bonding a thermoplastic tape to a substrate to form a fully consolidated composite. This device has an endless chain associated with a frame so as to rotate in a plane that is perpendicular to a long dimension of the tape, the chain having pivotally connected chain links with each of the links carrying a flexible foot member that extends outwardly from the chain. A selected number of the foot members contact the tape, after the heating thereof, to cause the heated tape to bond to the substrate. The foot members are each a thin band of metal oriented transversely to the chain, with a flexibility and width and length to contact the tape so as to cause the tape to conform to the substrate to achieve consolidation of the tape and the substrate. A biased leaf-type spring within the frame bears against an inner surface of the chain to provide the compliant pressure necessary to bond the tape to the substrate. The chain is supported by sprockets on shafts rotatably supported in the frame and, in one embodiment, one of the shafts has a drive unit to produce rotation such that the foot members in contact with the tape move at the same speed as the tape. Cooling jets are positioned along the frame to cool the resultant consolidated composite. 5 figures.

  13. Thermoplastic tape compaction device

    DOEpatents

    Campbell, Vincent W.

    1994-01-01

    A device for bonding a thermoplastic tape to a substrate to form a fully consolidated composite. This device has an endless chain associated with a frame so as to rotate in a plane that is perpendicular to a long dimension of the tape, the chain having pivotally connected chain links with each of the links carrying a flexible foot member that extends outwardly from the chain. A selected number of the foot members contact the tape, after the heating thereof, to cause the heated tape to bond to the substrate. The foot members are each a thin band of metal oriented transversely to the chain, with a flexibility and width and length to contact the tape so as to cause the tape to conform to the substrate to achieve consolidation of the tape and the substrate. A biased leaf-type spring within the frame bears against an inner surface of the chain to provide the compliant pressure necessary to bond the tape to the substrate. The chain is supported by sprockets on shafts rotatably supported in the frame and, in one embodiment, one of the shafts has a drive unit to produce rotation such that the foot members in contact with the tape move at the same speed as the tape. Cooling jets are positioned along the frame to cool the resultant consolidated composite.

  14. Thermoplastic tape compaction device

    SciTech Connect

    Campbell, V.W.

    1994-12-27

    A device is disclosed for bonding a thermoplastic tape to a substrate to form a fully consolidated composite. This device has an endless chain associated with a frame so as to rotate in a plane that is perpendicular to a long dimension of the tape, the chain having pivotally connected chain links with each of the links carrying a flexible foot member that extends outwardly from the chain. A selected number of the foot members contact the tape, after the heating thereof, to cause the heated tape to bond to the substrate. The foot members are each a thin bandmore » of metal oriented transversely to the chain, with a flexibility and width and length to contact the tape so as to cause the tape to conform to the substrate to achieve consolidation of the tape and the substrate. A biased leaf-type spring within the frame bears against an inner surface of the chain to provide the compliant pressure necessary to bond the tape to the substrate. The chain is supported by sprockets on shafts rotatably supported in the frame and, in one embodiment, one of the shafts has a drive unit to produce rotation such that the foot members in contact with the tape move at the same speed as the tape. Cooling jets are positioned along the frame to cool the resultant consolidated composite. 5 figures.« less

  15. A multicentre prospective randomised study of single-incision mini-sling (Ajust®) versus tension-free vaginal tape-obturator (TVT-O™) in the management of female stress urinary incontinence: pain profile and short-term outcomes.

    PubMed

    Mostafa, Alyaa; Agur, Wael; Abdel-All, Mohamed; Guerrero, Karen; Lim, Chi; Allam, Mohamed; Yousef, Mohamed; N'Dow, James; Abdel-fattah, Mohamed

    2012-11-01

    To compare the postoperative pain profile, peri-operative details, and short-term patient-reported and objective success rates of single-incision mini-slings (SIMS) versus standard mid-urethral slings (SMUS). In a multicentre prospective randomised trial in six UK centres in the period between October 2009 and October 2010, 137 women were randomised to either adjustable SIMS (Ajust®, C. R. Bard Inc., NJ, USA), performed under local anaesthesia as an opt-out policy (n=69), or SMUS (TVT-O™, Ethicon Inc., Somerville, USA) performed under general anaesthesia (n=68). Randomisation was done through number-allocation software and using telephone randomisation. Postoperative pain profile (primary outcome) was assessed on a ten-point visual analogue scale at fixed time-points. Pre- and post operatively (4-6 months) women completed symptom severity, urgency perception scale (UPS), quality of life and sexual function questionnaires. In addition, women completed a Patient Global Impression of Improvement Questionnaire and underwent a cough stress test at 4-6 months follow up. Sample size calculation was performed and data were analysed using SPSS 18. Descriptive analyses are given and between-group comparisons were performed using chi-square, Fischer exact test and Mann-Whitney test as appropriate. Significance level was set at 5%. Women in the SIMS Ajust® group had a significantly lower postoperative pain profile up to 4 weeks (p=<0.001, 95% CI 1.151, 2.480). There was no significant difference in peri-operative complications between groups. All 137 women completed the 4-6 months follow-up. Patient-reported and objective cure rates were not significantly different: 85.5% versus 91.2% (p=0.443) and 90% versus 97% (p=0.165) between the SIMS Ajust® and TVT-O™ groups respectively. There was a trend towards higher rates of de novo urgency or worsening of pre-existing urgency in the SIMS Ajust® group (21.7% versus 8.8%) but this did not reach statistical significance (p=0.063). Women in the SIMS Ajust® group had shorter hospital stay (median (IQR) 3.65 (2.49, 4.96)) compared to (4.42 (3.16, 5.56)) the TVT-O™ group 95% CI (-0.026, 1.326), with significantly earlier return to normal activities (p=0.025) and to work (p=0.006). The adjustable single-incision mini-sling (Ajust®) is associated with a significantly improved postoperative pain profile and earlier return to work when compared to standard mid-urethral slings (TVT-O™), with encouraging results in patient-reported and objective success rates at short-term follow-up. Copyright © 2012 Elsevier Ireland Ltd. All rights reserved.

  16. Caught (Unfortunately) on Tape

    ERIC Educational Resources Information Center

    Young, Jeffrey R.

    2009-01-01

    Recording class sessions so students can view them online is becoming routine on many campuses. But all that taping can lead to "uh-oh moments," such as when a professor's joke about the college dean ends up on YouTube, or a private comment to a student after class is inadvertently broadcast. Some lecture bloopers caught on tape are…

  17. Kinematics of Tape Recording.

    ERIC Educational Resources Information Center

    Coleman, J. J.

    1982-01-01

    Describes mathematics of the nonliner relationships between a constant-speed, capstan-driven magnetic tape transport mechanism and a constant-angular-velocity take-up reel. The relationship, derived from the sum of a partial, serves in recognition of a finite tape. Thickness can serve as an example of rotational kinematics. (Author/SK)

  18. Endovascular Management of Intractable Postpartum Hemorrhage Caused by Vaginal Laceration

    SciTech Connect

    Koganemaru, Masamichi, E-mail: mkoganemaru@med.kurume-u.ac.jp; Nonoshita, Masaaki, E-mail: z2rs-1973@yahoo.co.jp; Iwamoto, Ryoji, E-mail: iwamoto-ryouji@kurume-u.ac.jp

    PurposeWe evaluated the management of transcatheter arterial embolization for postpartum hemorrhage caused by vaginal laceration.Materials and MethodsWe reviewed seven cases of patients (mean age 30.9 years; range 27–35) with intractable hemorrhages and pelvic hematomas caused by vaginal lacerations, who underwent superselective transcatheter arterial embolization from January 2008 to July 2014. Postpartum hemorrhage was evaluated by angiographic vascular mapping to determine the vaginal artery’s architecture, technical and clinical success rates, and complications.ResultsThe vaginal artery was confirmed as the source of bleeding in all cases. The artery was found to originate from the uterine artery in three cases, the uterine and obturator arteriesmore » in two, or the internal pudendal artery in two. After vaginal artery embolization, persistent contrast extravasation from the inferior mesenteric artery as an anastomotic branch was noted in one patient. Nontarget vessels (the inferior vesical artery and nonbleeding vaginal arterial branches) were embolized in one patient. Effective control of hemostasis and no post-procedural complications were confirmed for all cases.ConclusionPostpartum hemorrhages caused by vaginal lacerations involve the vaginal artery arising from the anterior trunk of the internal iliac artery with various branching patterns. Superselective vaginal artery embolization is clinically acceptable for the successful treatment of vaginal laceration hemorrhages, with no complications. After vaginal artery embolization, it is suggested to check for the presence of other possible bleeding vessels by pelvic aortography with a catheter tip at the L3 vertebral level, and to perform a follow-up assessment.« less

  19. The effect of obturator bulb height on speech in maxillectomy patients.

    PubMed

    Kwon, H B; Chang, S W; Lee, S H

    2011-03-01

    The purpose of this study was to compare the speech function of low height bulb obturators with that of high height bulb obturators. Thirteen maxillectomy patients, who underwent post-operative prosthodontic rehabilitations, were included. Two obturators of the same design except for different bulb heights were fabricated for each maxillectomy patient. One of the two obturators had high bulb design and the other had low bulb design. After one of the obturators was used for a period of 3 weeks, the patient's speaking functions were evaluated by measuring nasalance scores, formant frequencies, and vowel working space areas. The same procedures were repeated with the second obturator following another 3-week period of usage. In addition, the effect of delivery sequence and anatomic conditions related to maxillectomy were analysed. The results demonstrated that the nasalance scores with the low bulb obturators were significantly higher than those with the high bulb obturators. There were no significant differences in formant frequencies based on the bulb height of the obturators. The vowel working spaces for the two obturators were similar in shape and there were no significant differences between the vowel working space areas created by the two obturators. The delivery sequence affected the results. However, there were no significant differences related to the other anatomical variables. Although low bulb obturators might function similarly with high bulb obturators in terms of the articulation of speech, they would exhibit a difficulty in controlling hypernasality in maxillectomy patients. © 2010 Blackwell Publishing Ltd.

  20. Speech rehabilitation of maxillectomy patients with hollow bulb obturator.

    PubMed

    Kumar, Pravesh; Jain, Veena; Thakar, Alok

    2012-09-01

    To evaluate the effect of hollow bulb obturator prosthesis on articulation and nasalance in maxillectomy patients. A total of 10 patients, who were to undergo maxillectomy, falling under Aramany classes I and II, with normal speech and hearing pattern were selected for the study. They were provided with definitive maxillary obturators after complete healing of the defect. The patients were asked to wear the obturator for six weeks and speech analysis was done to measure changes in articulation and nasalance at four different stages of treatment, namely, preoperative, postoperative (after complete healing, that is, 3-4 months after surgery), after 24 hours, and after six weeks of providing the obturators. Articulation was measured objectively for distortion, addition, substitution, and omission by a speech pathologist, and nasalance was measured by Dr. Speech software. The statistical comparison of preoperative and six weeks post rehabilitation levels showed insignificance in articulation and nasalance. Comparison of post surgery complete healing with six weeks after rehabilitation showed significant differences in both nasalance and articulation. Providing an obturator improves the speech closer to presurgical levels of articulation and there is improvement in nasality also.

  1. Speech Rehabilitation of Maxillectomy Patients with Hollow Bulb Obturator

    PubMed Central

    Kumar, Pravesh; Jain, Veena; Thakar, Alok

    2012-01-01

    Aim: To evaluate the effect of hollow bulb obturator prosthesis on articulation and nasalance in maxillectomy patients. Materials and Methods: A total of 10 patients, who were to undergo maxillectomy, falling under Aramany classes I and II, with normal speech and hearing pattern were selected for the study. They were provided with definitive maxillary obturators after complete healing of the defect. The patients were asked to wear the obturator for six weeks and speech analysis was done to measure changes in articulation and nasalance at four different stages of treatment, namely, preoperative, postoperative (after complete healing, that is, 3-4 months after surgery), after 24 hours, and after six weeks of providing the obturators. Articulation was measured objectively for distortion, addition, substitution, and omission by a speech pathologist, and nasalance was measured by Dr. Speech software. Results: The statistical comparison of preoperative and six weeks post rehabilitation levels showed insignificance in articulation and nasalance. Comparison of post surgery complete healing with six weeks after rehabilitation showed significant differences in both nasalance and articulation. Conclusion: Providing an obturator improves the speech closer to presurgical levels of articulation and there is improvement in nasality also. PMID:23440022

  2. [Trans-obturator urethral sling for surgical correction of female stress urinary incontinence: Outside-in (Monarc) versus inside-out (TVT-O). Are both ways safe?].

    PubMed

    Debodinance, P

    2006-10-01

    The originally described outside-in procedure for the trans-obturator route was later turned inside-out. We wanted to demonstrate the safety of the two techniques through personal and published experience. Non-randomized, prospective, observational, open-label, longitudinal study of 100 female patients (50 TVT-O and 50 Monarc). All the female patients presented with isolated stress urinary incontinence. Only 4 patients presented with mixed incontinence in the Monarc (MON) group. Sphincter incompetence was observed 4 times in the MON group and 3 times in the TVT-O group. All the patients underwent surgery under assisted local anesthesia in a day-hospital setting. Only those patients presenting with patent established urinary incontinence, corrected by the TVT test, underwent surgery. Post-operative control was conducted at 3 months and 1 year. The duration of hospitalization was 10 h for 48 patients in the MON group and 49 in the TVTO group. The only per-operative complication was a vaginal perforation in the lateral angle of the vagina for a MON patient. Early post-operative complications were observed in the MON group: 3 cases of urinary tract infection, 1 of transient urine retention, 3 of pain in the thighs spontaneously resolving within 4 days and 1 of permanent pain in one leg at time 1 year, which remained bearable. For the TVTO group the post-operative complications consisted in: 1 case of urinary tract infection, 1 of transient retention and 4 of pain in the thigh. No hematoma was reported in either group. Among the late complications, the de novo symptoms included 1 case of imperious urges to urinate in the TVTO group and objective dysuria in 2 cases in the MON group vs. 7 in the TVTO group. There was no statistically significant between-group difference in the complications. No tape exposure was observed. Overall, the recovery rate was 90% at 1 year for MON vs. 94% for TVTO (p = NS) with 2 cases of recurrence between 3 months and 1 year in that series

  3. Obturator externus was larger, while obturator internus size was similar in ballet dancers compared to nondancing athletes.

    PubMed

    Mayes, Susan; Ferris, April-Rose; Smith, Peter; Cook, Jill

    2018-06-02

    To compare the cross-sectional area (CSA) of hip external rotators, obturator externus (OE) and obturator internus (OI), in ballet dancers and nondancing athletes, and evaluate the relationship between obturator muscle size and hip pain. Case-control study. Elite ballet and sport. 33 male and female professional ballet dancers and 33 age and sex-matched athletes. CSA's of OE and OI measured on magnetic resonance imaging (MRI) of one hip. Hip pain was scored with the Copenhagen Hip and Groin Outcome Score (HAGOS): HAGOS pain score of 100 was defined as no pain and a score less than 100 was defined as pain. Participants weight and height. Estimated marginal mean CSA of OE was 14% larger in dancers than athletes (p = 0.01, ηp2 = 0.1); the size of OI was similar (p > 0.05). Men and women in both groups had similar sized OI and OE. There was no interaction between the estimated marginal mean CSA of either obturator and hip pain. It appears that ballet selectively increases muscle size of OE, but not OI. Obturator size was not related to mild hip pain, as OE and OI size was similar in dancers and athletes with and without pain. Copyright © 2018. Published by Elsevier Ltd.

  4. PHOTOELECTRIC CONTROL FOR TAPE POSITIONING

    DOEpatents

    Woody, J.W. Jr.

    1961-07-25

    A control system is described for producing control impulses which may be used to start, stop, and position a magnetic tape with respect to a transducer, and to locate discrete areas on the tape. Means are provided for positive identification of data blocks, exact positioning of the tape under the magnetic head, drive in either direction, accurate skip-over of imperfect regions of the tape, stopping the tape if equipment malfunction results in a failure to detect the block-identifying signals, and starting and stopping those parts of the tape between of the tape drive clutches.

  5. Yeast Infection (Vaginal)

    MedlinePlus

    Yeast infection (vaginal) Overview A vaginal yeast infection is a fungal infection that causes irritation, discharge and intense itchiness ... symptoms Causes The fungus candida causes a vaginal yeast infection. Your vagina naturally contains a balanced mix of yeast, including ...

  6. Vaginal yeast infection

    MedlinePlus

    Yeast infection - vagina; Vaginal candidiasis; Monilial vaginitis ... Most women have a vaginal yeast infection at some time. Candida albicans is a common type of fungus. It is often found in small amounts in the ...

  7. Vaginal bleeding in pregnancy

    MedlinePlus

    Pregnancy - vaginal bleeding; Maternal blood loss - vaginal ... Up to 1 in 4 women have vaginal bleeding at some time during their pregnancy. Bleeding is more common in the first 3 months (first trimester), especially with twins.

  8. Main image file tape description

    USGS Publications Warehouse

    Warriner, Howard W.

    1980-01-01

    This Main Image File Tape document defines the data content and file structure of the Main Image File Tape (MIFT) produced by the EROS Data Center (EDC). This document also defines an INQUIRY tape, which is just a subset of the MIFT. The format of the INQUIRY tape is identical to the MIFT except for two records; therefore, with the exception of these two records (described elsewhere in this document), every remark made about the MIFT is true for the INQUIRY tape.

  9. Tape recorder failure investigation

    NASA Technical Reports Server (NTRS)

    Higgins, M. D.; Loewenthal, S. H.; Carnahan, C. C.; Snyder, G. L.

    1996-01-01

    Two end-item tape recorders lost 4:1 mode data recording mode capability at less than half of their 1 6,000-cycle, 4-year operating life. Subsequent life tests on two spare recorders also experienced 4:1 mode data loss at 8,000 and 11,700 cycles. Tear down inspection after completion of the life tests showed that the tape had worn through the alfesil record and reproduce heads. An investigation was initiated to understand the cause of excessive tape head wear and the reasons why the 4:1 mode data rate, low-speed mode is more damaging than the 1:1 mode data rate, high-speed recording mode. The objective was to establish how operating conditions (tape speed, humidity, temperature, stop/start cycles) affects head life with the goal of extending head life on the remaining in-service tape recorders. Another interest was to explain why an earlier vendor life test showed capability beyond 16,000 cycles.

  10. A Conservative Method of Retaining an Interim Obturator for a Total Maxillectomy Patient

    PubMed Central

    Bettie, Nirmal Famila

    2017-01-01

    Interim obturators are indicated during the postsurgical phases. It promotes surgical healing and serves as a temporary prosthesis to rehabilitate a patient with intra-oral surgical defect. Retention is gained by wiring, surgical suturing, and other noninvasive methods to enable functional rehabilitation and easy replacement with a permanent obturator. Interim obturators serve as an easy guide for replacing with definitive obturators by indicating prosthesis extensions and the required method of retention. A more conservative and noninvasive method of retaining an interim obturator for a maxillectomy patient is described in this case report. PMID:29284985

  11. A Conservative Method of Retaining an Interim Obturator for a Total Maxillectomy Patient.

    PubMed

    Bettie, Nirmal Famila

    2017-11-01

    Interim obturators are indicated during the postsurgical phases. It promotes surgical healing and serves as a temporary prosthesis to rehabilitate a patient with intra-oral surgical defect. Retention is gained by wiring, surgical suturing, and other noninvasive methods to enable functional rehabilitation and easy replacement with a permanent obturator. Interim obturators serve as an easy guide for replacing with definitive obturators by indicating prosthesis extensions and the required method of retention. A more conservative and noninvasive method of retaining an interim obturator for a maxillectomy patient is described in this case report.

  12. The Carbon Monoxide Tape Recorder

    NASA Technical Reports Server (NTRS)

    Schoeberl, M. R.; Duncan, B. N.; Douglass, A. R.; Waters, J.; Livesey, N.; Read, W.; Filipiak, M.

    2006-01-01

    Using Aura MLS data we have identified the stratospheric tape recorder in carbon monoxide (CO). Unlike the water vapor tape recorder, which is controlled by upper troposphere processes, the CO tape recorder is linked to seasonal biomass burning. Since CO has a lifetime of only a few months, the CO tape recorder barely extends above 20 km. The tape head for CO appears to be close to 360K near the same location as the water vapor tape head [Read et al, 20041. Both tape heads are below the equatorial cold point tropopause but above the base of the tropical tropopause layer. The tape recorder signal becomes more distinct from 360K to 380K suggesting that convective detrainment of plays a decreasingly important role with altitude. The Global Modeling Initiative chemical transport model forced by the climatology of biomass burning reproduces the CO tape recorder.

  13. Tracer sensitive tapes

    NASA Technical Reports Server (NTRS)

    Burrows, W. H.; Burrows, W. H.

    1971-01-01

    A leak detection system has been developed, consisting of a tape that can be wrapped around possible leak sites on a system pressurized with air or gaseous nitrogen. Carbon monoxide, at a level of 100 to 1000 parts per million is used as a trace gas in the pressurized system. The sensitive element of the tape is palladium chloride supported on specially prepared silica gel and specially dried. At a CO level of 100 ppm and a leak rate of 10-20 ml/hr, discoloration of the sensitive element is observed in 1.5 to 3 min. The tape and trace gas are compatible with aerospace hardware, safe to handle, and economically reasonable to produce and handle.

  14. Comparison of different techniques for obturating experimental internal resorptive cavities.

    PubMed

    Goldberg, F; Massone, E J; Esmoris, M; Alfie, D

    2000-06-01

    Forty extracted maxillary central incisors were instrumented at the working length to a #50 file. The roots were sectioned transversely with a diamond disk at 7 mm from the anatomical apex. At the opening of the root canal of each section, hemicircular cavities were drilled with a specially designed bur. The corresponding root sections were cemented with glue, thus obtaining root canals with similar cavities that simulated internal resorptions. Teeth were embedded in plaster casts to facilitate their handling. The specimens were randomly separated into four groups of 10. The following obturation techniques were evaluated: lateral compaction (group A), hybrid technique (group B), Obtura II (group C), and Thermafil (group D). AH26 was used as the sealer. After obturation, the plaster was removed and the teeth were radiographed in buccolingual and mesiodistal directions to evaluate the quality of the obturation at the IRC. The incisors were then cut with a scalpel at the same level as the previous section, to examine, under a stereomicroscope, the type of material that filled the IRC. Obtura II gave the best results and in most of the specimens obturated with this technique, the IRC were filled mainly with gutta-percha. Statistical analysis of the data indicated that the differences between group C and the other groups were significant (P < 0.05).

  15. Stress analysis in oral obturator prostheses: imaging photoelastic

    NASA Astrophysics Data System (ADS)

    Pesqueira, Aldiéris Alves; Goiato, Marcelo Coelho; dos Santos, Daniela Micheline; Haddad, Marcela Filié; Andreotti, Agda Marobo; Moreno, Amália

    2013-06-01

    Maxillary defects resulting from cancer, trauma, and congenital malformation affect the chewing efficiency and retention of dentures in these patients. The use of implant-retained palatal obturator dentures has improved the self-esteem and quality of life of several subjects. We evaluate the stress distribution of implant-retained palatal obturator dentures with different attachment systems by using the photoelastic analysis images. Two photoelastic models of the maxilla with oral-sinus-nasal communication were fabricated. One model received three implants on the left side of the alveolar ridge (incisive, canine, and first molar regions) and the other did not receive implants. Afterwards, a conventional palatal obturator denture (control) and two implant-retained palatal obturator dentures with different attachment systems (O-ring; bar-clip) were constructed. Models were placed in a circular polariscope and a 100-N axial load was applied in three different regions (incisive, canine, and first molar regions) by using a universal testing machine. The results were photographed and analyzed qualitatively using a software (Adobe Photoshop). The bar-clip system exhibited the highest stress concentration followed by the O-ring system and conventional denture (control). Images generated by the photoelastic method help in the oral rehabilitator planning.

  16. Oral function after maxillectomy and reconstruction with an obturator.

    PubMed

    Kreeft, A M; Krap, M; Wismeijer, D; Speksnijder, C M; Smeele, L E; Bosch, S D; Muijen, M S A; Balm, A J M

    2012-11-01

    Maxillectomy defects can be reconstructed by a prosthetic obturator or (free) flap transfer, but there is no consensus about the optimal method. This study evaluated 32 maxillectomy patients with prosthetic obturation regarding function (mastication, subjective oral and swallowing complaints and maximal mouth opening). Outcomes were related to the extent of the resection (Brown maxillectomy classification), dentition and history of adjuvant radiotherapy. Maxillectomy defects ranged from 2-1 to 4B on the Brown classification, and most had a defect graded as 2-A or 2-B. Mean mixing ability test after 10 chewing strokes was 24.2 and after 20 chewing strokes 19.7, which compares to edentulous healthy individuals. None of the outcomes was influenced by Brown classification. Radiotherapy negatively influenced mean maximal mouth opening (29.1mm versus 40.9 mm, p=0.017) and subjective outcomes. Edentate obturated patients had worse outcomes than dentate patients, measured by mixing ability test and questionnaire. In conclusion, mastication after obturator reconstruction of a maxillectomy defect is comparable to mastication with full dentures. Size of the maxillectomy defect did not significantly influence functional outcome, but adjuvant radiotherapy resulted in worse mouth opening and self-reported oral and swallowing problems. Residual dentition had a positive influence on mastication and subjective outcomes. Copyright © 2012 International Association of Oral and Maxillofacial Surgeons. Published by Elsevier Ltd. All rights reserved.

  17. Magnetic Tape Recording

    NASA Technical Reports Server (NTRS)

    Athey, Skipwith W.

    1966-01-01

    NASA's contribution to tape recorder technology may appear to lie in such glamorous devices as the tape recorders of the Tiros and Nimbus satellites which receive signals carrying weather information during an orbit around the earth and then transmit those signals back to the ground when the satellite is in view of ground stations. These quite important recording devices are, however, only useful as members of a complex hierarchy of devices all of which participate in the ultimate process of obtaining information from NASA's efforts. Their existence and utility is based on the existence of many more prosaic recording devices which have been involved in the development of such spectacular units.

  18. Quality of life after maxillectomy and prosthetic obturator rehabilitation.

    PubMed

    Chigurupati, Radhika; Aloor, Neelam; Salas, Richard; Schmidt, Brian L

    2013-08-01

    Surgical resection of midface neoplasms and subsequent reconstruction have been shown to have significant negative effects on quality of life (QOL). The purpose of this pilot study was to assess individuals' health-related QOL after maxillectomy and reconstruction with a prosthetic obturator. The QOL of 25 of 43 patients who underwent maxillectomy and prosthetic obturator reconstruction at the University of California-San Francisco was assessed using 3 questionnaires: University of Washington Quality of Life version 4 (UWQOL), Obturator Functioning Scale (OFS), and Mental Health Inventory (MHI). The response rate to the QOL questionnaires was 92% (23 of 25 patients). Time elapsed from maxillectomy and prosthetic obturator reconstruction to the QOL survey response ranged from 0.3 to 6.6 years (mean, 2.7 years; standard deviation [SD], 1.9 years). The post-treatment mean QOL scores were 77.3 (SD, 13.6) for UWQOL, 72.0 (SD, 12.6) for OFS, and 4.5 (SD, 0.9) for Mental Health Inventory. Individuals who received adjuvant radiation scored lower for speech and appearance (OFS, P = .05, P = .03, respectively) as well as for saliva and overall QOL (UWQOL, P = .02, P = .08, respectively). There was a strong correlation between QOL scores in OFS and UWQOL questionnaires (r = 0.78, P < .001). The results of this pilot study suggest that postoperative radiation therapy was the strongest variable affecting QOL in patients with maxillectomy and prosthetic obturator reconstruction. There is further need for a multicenter trial with a larger sample to identify how factors affecting QOL of patients after maxillectomy might influence the choice of reconstruction. Copyright © 2013 American Association of Oral and Maxillofacial Surgeons. Published by Elsevier Inc. All rights reserved.

  19. Vaginal Cancer Overview

    MedlinePlus

    ... are here Home > Types of Cancer > Vaginal Cancer Vaginal Cancer This is Cancer.Net’s Guide to Vaginal Cancer. Use the menu below to choose the ... social workers, and patient advocates. Cancer.Net Guide Vaginal Cancer Introduction Statistics Medical Illustrations Risk Factors and ...

  20. Helical tape forming device

    NASA Technical Reports Server (NTRS)

    Bush, J. E.; Cole, P. T.

    1969-01-01

    Using a device that is not limited to a minimum thickness or width-to-thickness ratio, a very thin metal tape or ribbon is formed into a continuous flat wound helical coil. The device imparts the desired circular shape by squeeze rolling it with an unequal force across its width.

  1. Determination of a Central Avascular Triangle within the Obturator Foramen: A Radioanatomic Study

    PubMed Central

    Nyangoh Timoh, Krystel; Bader, Georges; Fauconnier, Arnaud; Barrau, Vincent; Delmas, Vincent; Touboul, Cyril

    2015-01-01

    Purpose To map the vascular anatomy of the obturator foramen using fixed anatomic landmarks. Method Twenty obturator regions were dissected in 10 fresh female cadavers after vascular blue dye injection in five cadavers (50%). Furthermore, 104 obturator regions were reconstructed by angiotomodensitometry from 52 women under investigation for suspected arterial disease. The anatomy of the obturator region was mapped by measuring the distance of vascular structures from the middle of the two branches of the ischiopubic bone, which were used as fixed landmarks. Results The bifurcation of the obturator artery was at a mean (SD) distance of 30.0 mm (4.5) from the middle of the ischiopubic branch (MISP). The anterior branch of the obturator vessels was 15.2 mm (10.1) from the MISP. The posterior branch of the obturator vessels was 5.5 mm (4.0) and 23.6 mm (8.7) from the middle of the outer edge of the obturator foramen (MOE) and the MISP, respectively. Using 5° and 95° percentiles of these measurements we defined a central avascular triangle. Conclusions Our data show that, beyond inter-individual variations, a central triangular avascular area can be identified in the obturator foramen between the posterior and anterior obturator artery using fixed landmarks. PMID:26624993

  2. Tape tracking and handling for magnetic tape recorders. [aboard spacecraft

    NASA Technical Reports Server (NTRS)

    Paroby, W.; Disilvestre, R.

    1975-01-01

    One of the critical performance and life limiting elements of a spacecraft tape recorder instrumentation system which has received little attention in technical literature is magnetic tape tracking and handling technology. This technology is required to understand how to gently transfer tape from one reel to another with proper alignment and a desirable uniform velocity at the read and write transducer heads. The increased demand for high data rate (i.e., multi-track spacecraft recording instrumentation systems), coupled with performance under extreme environmental conditions, requires a thorough knowledge of the various parameters which establish an optimum designed tape tracking and handling system. Stress analysis techniques are required to evaluate these parameters substantiated with test tape tracking data, to show the effect of each parameter on a tape recorder instrumentation tracking system. The technology is applicable to ground type tape recorders where the detrimental effects of edge guidance can be eliminated.

  3. Automated Tape Laying Machine for Composite Structures.

    DTIC Science & Technology

    The invention comprises an automated tape laying machine, for laying tape on a composite structure. The tape laying machine has a tape laying head...neatly cut. The automated tape laying device utilizes narrow width tape to increase machine flexibility and reduce wastage.

  4. [Clinical-diagnostic estimation of carbohydrates metabolism in obturation jaundice].

    PubMed

    Nychytaĭlo, M Iu; Malyk, S V

    2004-07-01

    Complex examination of 175 patients with obturation jaundice was conducted, peculiar attention was spared to the carbohydrates metabolism changes, characterizing hepatic state. It was established, that in obturation jaundice in the liver there are occurring inflammatory changes and disturbances of all kinds of metabolism, including that of carbohydrates, severity of which depends on duration of jaundice, the concurrent diseases presence, they shows lowering of the glucose and glycogen level in the blood, as well as the hepatic glycogen content, that's why they may be applied as a complex of prognostic criterions for the disease course. An early conduction of operative treatment, elimination of the biliary ducts impassability promote the rehabilitation period shortening and the hepatic functional activity normalization.

  5. Management of maxillectomy defect with a hybrid hollow bulb obturator

    PubMed Central

    Singh, Kamleshwar; Singh, Saumyendra V; Mishra, Niraj; Agrawal, Kaushal Kishor

    2013-01-01

    A woman having already undergone maxillectomy came to the department complaining of difficulty in eating and speech. During the construction of an obturator, the bulb area should be hollowed to reduce weight so that the teeth and supporting tissues are not stressed unnecessarily. The conventional open design drains fluid from the adjacent mucosa, possibly increasing the weight of the prosthesis, and is difficult to clean. The closed bulb design does not drain secretions and may cause obstruction and susceptibility to infection in the paranasal and pharyngeal regions, though it is easier to maintain. An alternative to the two designs, combining their advantages, is presented in this report. As the open hollow part of the obturator was shallow, it was easy to clean. Making the inferior part of the bulb hollow and closed led to a reduction in the overall weight of the prosthesis while increasing its resonance. PMID:23436886

  6. Effects of different root canal obturation techniques on bacterial penetration.

    PubMed

    Yücel, Ali Cağin; Ciftçi, Alper

    2006-10-01

    The aim of this study was to compare bacterial penetration following obturation with 5 different techniques. This study was performed on 120 teeth including negative control (n = 10), positive control (n = 10), and experimental groups (n = 100). One hundred teeth were randomly divided into 5 groups of 20 teeth each and obturated with System B (Sb), Lateral Compaction (Lc), Thermafil (T), Single ProTaper Gutta-percha (P), and laterally compacted ProTaper Gutta-percha (PLc). Enterococcus faecalis was used for determination of the bacterial penetration. Evaluation was carried out for 60 days. At 30 days, the chi2 test showed that the slowest penetration was observed in Group Sb and Group PLc, which were not significantly different from each other. The fastest penetration in the all experimental groups was observed in Group T and Group P, which were not significantly different from one another. Also, there was no statistically significance difference (P > .05) among all groups at 60 days. It may be concluded that under the conditions of this study System B and laterally compacted ProTaper Gutta-percha prevent bacterial penetration of the root canal at 30 days. Furthermore, there was no difference among obturation techniques at 60 days.

  7. Tension free vaginal tape (TVT) vs Transobturator tape (TOT) complications and outcomes.

    PubMed

    Potić, Milan; Ignjatović, Ivan; Bašić, Dragoslav

    2014-01-01

    Stress urinary incontinence (SUI) is managed with both TVT and TOT. The TVT route of placement could result in a higher com-plication rate. The aim of this study is to analyze and compare outcomes and complications of TVT and TOT in SUI treatment. Prospective study in 64 women with isolated SUI was validated through Urogenital Distress Inventory (UDI-6), Incontinence Impact questionnaire (IIQ-7) and International Continence Impact Questionnaire (ICIQ5-SF). Intraoperative and postoperative complications were noted. Patients were considered cured when negative on stress test and with no need for additional surgery during follow up, after one and three months. The cure rates for both TVT 26/30 (86,6%) and TOT 30/34 (88,2) were comparable. Higher rates of bleeding, bladder perforations, pain and dyspareunia are recorded in TVT group. Quality of life graded on the questionnaire basis proved significant improvement in both procedures. Both TVT and TOT have comparable cure results in the treatment of SUI. The TOT is equally effective in the SUI treatment with significantly lower complication incidence.

  8. Enhanced retention of a maxillofacial prosthetic obturator using precision attachments: Two case reports

    PubMed Central

    Murat, Sema; Gurbuz, Ayhan; Isayev, Abulfaz; Dokmez, Bahadir; Cetin, Unsun

    2012-01-01

    The majority of maxillary defects can be rehabilitated with conventional simple obturator prosthesis. However, inadequate retention, stability and support may be associated with the use of an obturator. Precision attachments have been used to retain obturators for some time. The use of precision attachments in a dentate maxillectomy patient can yield significant functional improvement while maintaining the obturator’s aesthetic advantages. This clinical report describes the prosthetic rehabilitation of two maxillary defects with an obturator retained using extracoronal resilient precision attachments. PMID:22509126

  9. Inflatable hollow obturator prostheses for patients undergoing an extensive maxillectomy: a case report

    PubMed Central

    Hou, Yue-Zhong; Huang, Zhi; Ye, Hong-Qiang; Zhou, Yong-Sheng

    2012-01-01

    The presence of a large palatal or maxillary defect after partial or total maxillectomy for tumor, trauma or congenital deformation poses a challenge to prosthodontists, particularly when the use of an implant cannot be considered. This case report described the use of an air valve in a hollow silicone obturator to manufacture an inflatable obturator that could be extended further into undercut area to retain itself. The inflatable obturator exhibited adequate retention, stability and border sealing, thereby improving the masticatory, pronunciation and swallowing functions of patients. It may be a suitable alternative treatment option to an implant-retained obturator. PMID:22653550

  10. Management of aerobic vaginitis.

    PubMed

    Tempera, Gianna; Furneri, Pio Maria

    2010-01-01

    Aerobic vaginitis is a new nonclassifiable pathology that is neither specific vaginitis nor bacterial vaginosis. The diversity of this microbiological peculiarity could also explain several therapeutic failures when patients were treated for infections identified as bacterial vaginosis. The diagnosis 'aerobic vaginitis' is essentially based on microscopic examinations using a phase-contrast microscope (at ×400 magnification). The therapeutic choice for 'aerobic vaginitis' should take into consideration an antibiotic characterized by an intrinsic activity against the majority of bacteria of fecal origin, bactericidal effect and poor/absent interference with the vaginal microbiota. Regarding the therapy for aerobic vaginitis when antimicrobial agents are prescribed, not only the antimicrobial spectrum but also the presumed ecological disturbance on the anaerobic and aerobic vaginal and rectal microbiota should be taken into a consideration. Because of their very low impact on the vaginal microbiota, kanamycin or quinolones are to be considered a good choice for therapy. Copyright © 2010 S. Karger AG, Basel.

  11. Vaginal sponge and spermicides

    MedlinePlus

    Birth control - over the counter; Contraceptives - over the counter; Family planning - vaginal sponge; Contraception - vaginal sponge ... preventing pregnancy as some other forms of birth control. However, using a spermicide or sponge is much ...

  12. Assisted Vaginal Delivery

    MedlinePlus

    ... Patient Education FAQs Assisted Vaginal Delivery Patient Education Pamphlets - Spanish Assisted Vaginal Delivery FAQ192, February 2016 PDF ... on Patient Safety For Patients Patient FAQs Spanish Pamphlets Teen Health About ACOG About Us Leadership & Governance ...

  13. Vaginitis test - wet mount

    MedlinePlus

    ... prep - vaginitis; Vaginosis - wet mount; Trichomoniasis - wet mount; Vaginal candida - wet mount ... provider gently inserts an instrument (speculum) into the vagina to hold it open and view inside. A ...

  14. Tape Placement Head for Applying Thermoplastic Tape to an Object

    NASA Technical Reports Server (NTRS)

    Cope, Ralph D. (Inventor); Funck, Steve B. (Inventor); Gruber, Mark B. (Inventor); Lamontia, Mark A. (Inventor); Johnson, Anthony D. (Inventor)

    2008-01-01

    A tape placement head for applying thermoplastic tape to an object includes a heated feeder which guides the tape/tow to a heated zone. The heated zone has a line compactor having a single row of at least one movable heated member. An area compactor is located in the heated zone downstream from the line compactor. The area compactor includes a plurality of rows of movable feet which are extendable toward the tape/tow different distances with respect to each other to conform to the shape of the object. A shim is located between the heated compactors and the tape/tow. A chilled compactor is in a chilled zone downstream from the heated zone. The chilled zone includes a line chilled compactor and an area chilled compactor. A chilled shim is mounted between the chilled compactor and the tape/tow.

  15. Obturator Neuromodulation with Laparoscopic Placement of an Obturator Lead for the Treatment of Intractable Opioid Dependent Chronic Pelvic Pain due to Obturator Neuralgia.

    PubMed

    Marvel, Richard P

    2018-05-12

    Chronic pelvic pain(CPP) is a common condition in women that can have a devastating effect on quality of life. Some of the most severe forms of CPP are related to peripheral nerve injuries causing persistent neuropathic pain. This is a case of a young woman with severe opioid dependent chronic pelvic and right groin pain due to obturator neuralgia. She had failed a multitude of treatments including multiple medications, manual physical therapy, nerve blocks, surgical neurolysis and spinal cord stimulation without significant benefit. She underwent a trial of peripheral neuromodulation of the obturator nerve with laparoscopic placement of a quadripolar lead. During the 6-day trial she had almost complete relief of her pain; therefore, she underwent permanent implantation of an intermittent pulse generator. Over the next 6 months she was completely weaned completely off her chronic opioids. At 23 months post implantation, she had essentially no pain and is no longer on any analgesic, antidepressant or membrane stabilizing medications. Peripheral Neuromodulation has the potential to alleviate pain and significantly improve quality of life in women with longstanding neuropathic chronic pelvic pain who have failed multimodal conservative therapy. Copyright © 2018. Published by Elsevier Inc.

  16. Magnetic Tape Recording for the Eighties

    NASA Technical Reports Server (NTRS)

    Kalil, Ford (Editor)

    1982-01-01

    The practical and theoretical aspects of state-of-the-art magnetic tape recording technology are reviewed. Topics covered include the following: (1) analog and digital magnetic tape recording, (2) tape and head wear, (3) wear testing, (4) magnetic tape certification, (5) care, handling, and management of magnetic tape, (6) cleaning, packing, and winding of magnetic tape, (7) tape reels, bands, and packaging, (8) coding techniques for high-density digital recording, and (9) tradeoffs of coding techniques.

  17. Fully synthetic taped insulation cables

    DOEpatents

    Forsyth, Eric B.; Muller, Albert C.

    1984-01-01

    A high voltage oil-impregnated electrical cable with fully polymer taped insulation operable to 765 kV. Biaxially oriented, specially processed, polyethylene, polybutene or polypropylene tape with an embossed pattern is wound in multiple layers over a conductive core with a permeable screen around the insulation. Conventional oil which closely matches the dielectric constant of the tape is used, and the cable can be impregnated after field installation because of its excellent impregnation characteristics.

  18. Five year magnetic tape for unattended satellite tape recorders

    NASA Technical Reports Server (NTRS)

    Benn, G. S. L.; Gutfreund, K.

    1972-01-01

    The development and fabrication of a quantity of long life magnetic tape with properties selected specifically for unattended operation in spacecraft tape recorders was studied. A detailed analytical consideration of various binder systems was undertaken. This included the chemical aspects of the binders, cohesion and adhesion effects, stability and the mechanical and physical properties. The ability to form free films of these polymers and their combination with various oxide loadings and other additives allowed a rapid selection of four polymer candidates for a five year magnetic tape. Samples were evaluated under actual running conditions which included physical, magnetic, and extensive life testing. These sample tapes withstood 50,000 bidirectional tape passes under fairly harsh operating conditions.

  19. Volumetric Evaluation of Different Obturation Techniques in Primary Teeth Using Spiral Computed Tomography.

    PubMed

    Nagaveni, N B; Yadav, Sneha; Poornima, P; Reddy, Vv Subba; Roshan, N M

    Various obturation techniques have been evaluated for better filling of the root canals in primary teeth using different methods. Spiral Computed Tomography (SCT) is a new revolution in the pediatric endodontics for assessment of quality of the obturation from 3 dimensions. To evaluate the efficiency of 5 different obturation methods in delivering the filling material into the canals of primary teeth using Spiral Computed Tomography scan. A total of 50 canals of primary teeth were prepared, divided into 5 groups with 10 canals in each group and obturated with Zinc Oxide Eugenol cement using 5 different obturation techniques such as Local anesthetic syringe, Tuberculin syringe, Endodontic plugger, hand held Lentulo-spiral, and Lentulo-spiral mounted on slow speed hand piece. The pre and post obturation volume and finally the Percentage of Obturated Volume (POV) were calculated using SCT scan for each group. The data obtained was statistically analyzed using One-way Analysis of Variance (ANOVA) and Tukey's post-hoc test. Lentulo-spiral hand held showed highest POV value followed by Lentulospiral mounted to hand piece, Tuberculin syringe and Endodontic plugger; whereas Anesthetic syringe had least POV (P < 0.05). Lentulo-spiral hand held is the best obturating technique among the 5 groups evaluated as the canals of this group showed maximum percentage of filled material. However, a further study with large sample size is highly essential.

  20. [Iatrogenic risks during the obturation of the root canal system].

    PubMed

    Aesaert, G

    2000-01-01

    A hermetic seal is the main goal of obturation of the root canal system. For that purpose guttapercha still remains the filling material of choice. Most filling techniques use plasticized guttapercha and a condensation technique to fulfil the requirements of hermetic seal. The heat to plasticize and the forces applied to condense that material may have an influence on the periodontal ligament and/or the remaining tooth structure. Furthermore can overfilling of guttapercha and more likely the sealer, affect the periodontal tissue. Although rare, mandibular nerve damage and adverse effects on the sinus maxillaris can be the result of inadequate treatment.

  1. ICI optical data storage tape

    NASA Technical Reports Server (NTRS)

    Mclean, Robert A.; Duffy, Joseph F.

    1991-01-01

    Optical data storage tape is now a commercial reality. The world's first successful development of a digital optical tape system is complete. This is based on the Creo 1003 optical tape recorder with ICI 1012 write-once optical tape media. Several other optical tape drive development programs are underway, including one using the IBM 3480 style cartridge at LaserTape Systems. In order to understand the significance and potential of this step change in recording technology, it is useful to review the historical progress of optical storage. This has been slow to encroach on magnetic storage, and has not made any serious dent on the world's mountains of paper and microfilm. Some of the reasons for this are the long time needed for applications developers, systems integrators, and end users to take advantage of the potential storage capacity; access time and data transfer rate have traditionally been too slow for high-performance applications; and optical disk media has been expensive compared with magnetic tape. ICI's strategy in response to these concerns was to concentrate its efforts on flexible optical media; in particular optical tape. The manufacturing achievements, media characteristics, and media lifetime of optical media are discussed.

  2. An improved magnetic tape recorder

    NASA Technical Reports Server (NTRS)

    Uber, P. W.

    1968-01-01

    Magnetic tape recorder employs a single capstan for simultaneously driving the supply and take-up reels in such a manner that the tape passing between the reels is kept under a predetermined constant tension. This recorder operates with little power and is sufficiently rugged to withstand the severe stresses encountered in high-altitude balloon flight tests.

  3. Wire and Packing Tape Sandwiches

    ERIC Educational Resources Information Center

    Rabinowitz, Sandy

    2009-01-01

    In this article, the author describes how students can combine craft wire with clear packing tape to create a two-dimensional design that can be bent and twisted to create a three-dimensional form. Students sandwich wire designs between two layers of tape. (Contains 1 online resource.)

  4. Archive Data Tape Library (ADTL)

    DOT National Transportation Integrated Search

    1983-01-01

    The purpose of this directory is to describe the procedures involved in using the ADTL as well as to identify and describe the data tapes contained in the ADTL. This directory provides a listing of the data tapes contained in the ADTL by mode of tran...

  5. Tape/head interface study

    NASA Technical Reports Server (NTRS)

    1983-01-01

    Existing high energy tapes, high track density heads, and transport guidance techniques were evaluated and characterized to enable these technologies to be employed in future spacecraft recorders with high confidence. The results of these study efforts demonstrated tracking accuracy tape and head density that will support spacecraft recorders with data rates of a minimum of 150 Mbps and storage capacities ranging from 10 to the 10th to 10 to the 11th bits. Seven high energy tapes of either .25 in width, 1.00 in width, or both, were tested. All tapes were tested at the same speed (30 ips) and the same packing density (33 KBI). The performance of all 1 in tapes was considered superior.

  6. Measurement of the percentage of root filling in oval-shaped canals obturated with Thermafil Obturators and Beefill 2in1: In vitro study

    PubMed Central

    Collado-Castellanos, Nicolás; Alegre-Domingo, Teresa; Dolz-Solsona, María; Faus-Matoses, Vicente

    2015-01-01

    Background The aim of the study was to measure the percentage of root canal fillings in long oval canals obturated with thermoplasticized gutta-percha techniques, Beefill 2in1® and Thermafil Obturators®. Material and Methods Fifty four mandibular incisors were selected after bucco-lingual and mesio-distal radiographs showed at 5 mm from apex an internal long:short diameter ≥2. Teeth were instrumented with Protaper Universal and divided in two groups of 27. Group 1 was obturated with Thermafil Obturators® and group 2 with Beefill 2in1®. Two horizontal sections were cut at 5 and 7 mm from the apex and photographed in a stereo-microscope. The total area of the canal and filled canal in cross-sections were measured with AutoCad and the percentages of gutta-percha-sealer and voids in the canal were obtained. Results Both systems achieved high percentage of filled canal, Thermafil 96.8% and Beefill 2in1 98.9%. The percentages of voids in both groups were very low. No significant differences were found between the two groups . The percentage obtained at 5 and 7 mm from the apex in both groups showed no significant difference. Conclusions The percentages of filled canal (gutta-percha-sealer) were high and these two thermoplasticized techniques are suitable for long oval canals obturation. Key words:Long oval canal, oval canal, thermoplasticized obturation. PMID:26155350

  7. Measurement of the percentage of root filling in oval-shaped canals obturated with Thermafil Obturators and Beefill 2in1: In vitro study.

    PubMed

    Faus-Llácer, Vicente; Collado-Castellanos, Nicolás; Alegre-Domingo, Teresa; Dolz-Solsona, María; Faus-Matoses, Vicente

    2015-04-01

    The aim of the study was to measure the percentage of root canal fillings in long oval canals obturated with thermoplasticized gutta-percha techniques, Beefill 2in1® and Thermafil Obturators®. Fifty four mandibular incisors were selected after bucco-lingual and mesio-distal radiographs showed at 5 mm from apex an internal long:short diameter ≥2. Teeth were instrumented with Protaper Universal and divided in two groups of 27. Group 1 was obturated with Thermafil Obturators® and group 2 with Beefill 2in1®. Two horizontal sections were cut at 5 and 7 mm from the apex and photographed in a stereo-microscope. The total area of the canal and filled canal in cross-sections were measured with AutoCad and the percentages of gutta-percha-sealer and voids in the canal were obtained. Both systems achieved high percentage of filled canal, Thermafil 96.8% and Beefill 2in1 98.9%. The percentages of voids in both groups were very low. No significant differences were found between the two groups . The percentage obtained at 5 and 7 mm from the apex in both groups showed no significant difference. The percentages of filled canal (gutta-percha-sealer) were high and these two thermoplasticized techniques are suitable for long oval canals obturation. Key words:Long oval canal, oval canal, thermoplasticized obturation.

  8. Vaginitis: diagnosis and management.

    PubMed

    Faro, S

    1996-01-01

    The various conditions that give rise to vaginitis include specific and nonspecific entities, such as candidiasis, trichomoniasis, bacterial vaginosis, group B streptococcal vaginitis, purulent vaginitis, volvodynia, and vestibulitis. The patient with chronic vaginitis usually develops this condition because of a misdiagnosis. It is critical that patients who have chronic vaginitis be thoroughly evaluated to determine if there is a specific etiology and whether their condition is recurrent or persistent, or is a reinfection. This also must include obtaining a detailed history, beginning with the patient's best recollection of when she felt perfectly normal. The physician must have an understanding of a healthy vaginal ecosystem and what mechanisms are in place to maintain the equilibrium. The vaginal ecosystem is a complex system of micro-organisms interacting with host factors to maintain its equilibrium. The endogenous microflora consists of a variety of bacteria, which include aerobic, facultative and obligate anaerobic bacteria. These organisms exist in a commensal, synergistic or antagonistic relationship. Therefore, it is important to understand what factors control the delicate equilibrium of the vaginal ecosystem, and which factors, both endogenous and exogenous, can disrupt this system. It is also important for the physician to understand that when a patient has symptoms of vaginitis it is not always due to an infectious etiology. There are situations in which an inflammatory reaction occurs but the specific etiology may not be determined. Thus, it is important that the physician not rush through the history or the examination.

  9. Vaginal foreign bodies.

    PubMed

    Stricker, T; Navratil, F; Sennhauser, F H

    2004-04-01

    To evaluate the clinical features and outcome in girls with a vaginal foreign body. Retrospective review of medical records of 35 girls with a vaginal foreign body seen in an outpatient clinic for paediatric and adolescent gynaecology between 1980 and 2000. The ages ranged from 2.6 to 9.2 years. The most common symptom was blood-stained vaginal discharge/vaginal bleeding (49%). Duration of symptoms varied from 1 day to 2 years. Fifty-four percent of the patients recalled insertion of the foreign object, usually by the girl herself. All but three patients (91%) either recalled insertion of the foreign object and/or had vaginal bleeding or blood-stained or foul-smelling vaginal discharge, and/or visualization or palpation of the foreign body in physical examination. Symptoms resolved after removal of the foreign body followed by a single irrigation with Providon-Iod (Betadine). In the majority of patients a carefully obtained history and physical examination suggest the diagnosis of a vaginal foreign object. The leading symptoms are vaginal bleeding and blood-stained or foul smelling vaginal discharge. Removal of the foreign object followed by a single irrigation with Providon-Iod is the definitive treatment and does not require additional measures.

  10. Clothing factors and vaginitis.

    PubMed

    Heidrich, F E; Berg, A O; Bergman, J J

    1984-10-01

    Associations of clothing factors and vulvovaginal symptoms, signs, and microbiology were sought in 203 women seeking care at a university family medicine clinic. Clothing factors studied were use of panty hose, underwear for sleep, cotton lining panels, and pants vs skirts. Women wearing and not wearing panty hose had similar rates of vaginitis symptoms and signs, but yeast vaginitis was about three times more common among wearers. Relationships of other clothing factors to vaginitis were not found. Nonspecific vaginitis was not found to be related to clothing.

  11. Asteroid Composite Tape

    NASA Astrophysics Data System (ADS)

    1998-07-01

    This is a composite tape showing 10 short segments primarily about asteroids. The segments have short introductory slides, which include brief descriptions about the shots. The segments are: (1) Radar movie of asteroid 1620 Geographos; (2) Animation of the trajectories of Toutatis and Earth (3) Animation of a landing on Toutatis; (4) Simulated encounter of an asteroid with Earth, includes a simulated impact trajectory; (5) An animated overview of the Manrover vehicle; (6) The Near Earth Asteroid Tracking project, includes a photograph of USAF Station in Hawaii, and animation of Earth approaching 4179 Toutatis and the asteroid Gaspara; (7) live video of the anchor tests of the Champoleon anchoring apparatus; (8) a second live video of the Champoleon anchor tests showing anchoring spikes, and collision rings; (9) An animated segment with narration about the Stardust mission with sound, which describes the mission to fly close to a comet, and capture cometary material for return to Earth; (10) live video of the drop test of a Stardust replica from a hot air balloon; this includes sound but is not narrated.

  12. Performance of preformed plastic tapes.

    DOT National Transportation Integrated Search

    1982-01-01

    This study was initiated to investigate the overall performance of preformed pavement marking tapes with respect to their appearance, durability, and night visibility, and to recommend criteria for the selection of such materials based on their perfo...

  13. ICI optical data storage tape

    NASA Technical Reports Server (NTRS)

    Mclean, Robert A.; Duffy, Joseph F.

    1992-01-01

    Optical data storage tape is now a commercial reality. The world's first successful development of a digital optical tape system is complete. This is based on the Creo 1003 optical tape recorder with ICI 1012 write-once optical tape media. Flexible optical media offers many benefits in terms of manufacture; for a given capital investment, continuous, web-coating techniques produce more square meters of media than batch coating. The coated layers consist of a backcoat on the non-active side; on the active side there is a subbing layer, then reflector, dye/polymer, and transparent protective overcoat. All these layers have been tailored for ease of manufacture and specific functional characteristics.

  14. String and Sticky Tape Experiments.

    ERIC Educational Resources Information Center

    Edge, R. D., Ed.

    1979-01-01

    Explains how to demonstrate the fundamentals of one dimensional kinematics such as Newton's third law of motion, and collision between bodies, using simple materials of marbles, strings, sticky tape, drinking straws, and rubber bands. (GA)

  15. Casting Of Multilayer Ceramic Tapes

    NASA Technical Reports Server (NTRS)

    Collins, Earl R., Jr.

    1991-01-01

    Procedure for casting thin, multilayer ceramic membranes, commonly called tapes, involves centrifugal casting at accelerations of 1,800 to 2,000 times normal gravitational acceleration. Layers of tape cast one at a time on top of any previous layer or layers. Each layer cast from slurry of ground ceramic suspended in mixture of solvents, binders, and other components. Used in capacitors, fuel cells, and electrolytic separation of oxygen from air.

  16. Stress analysis in oral obturator prostheses, part II: photoelastic imaging

    NASA Astrophysics Data System (ADS)

    Pesqueira, Aldiéris Alves; Goiato, Marcelo Coelho; da Silva, Emily Vivianne Freitas; Haddad, Marcela Filié; Moreno, Amália; Zahoui, Abbas; dos Santos, Daniela Micheline

    2014-06-01

    In part I of the study, two attachment systems [O-ring; bar-clip (BC)] were used, and the system with three individualized O-rings provided the lowest stress on the implants and the support tissues. Therefore, the aim of this study was to assess the stress distribution, through the photoelastic method, on implant-retained palatal obturator prostheses associated with different attachment systems: BOC-splinted implants with a bar connected to two centrally placed O-rings, and BOD-splinted implants with a BC connected to two distally placed O-rings (cantilever). One photoelastic model of the maxilla with oral-sinus-nasal communication with three parallel implants was fabricated. Afterward, two implant-retained palatal obturator prostheses with the two attachment systems described above were constructed. Each assembly was positioned in a circular polariscope and a 100-N axial load was applied in three different regions with implants by using a universal testing machine. The results were obtained through photograph record analysis of stress. The BOD system exhibited the highest stress concentration, followed by the BOC system. The O-ring, centrally placed on the bar, allows higher mobility of the prostheses and homogeneously distributes the stress to the region of the alveolar ridge and implants. It can be concluded that the use of implants with O-rings, isolated or connected with a bar, to rehabilitate maxillectomized patients allows higher prosthesis mobility and homogeneously distributes the stress to the alveolar ridge region, which may result in greater chewing stress distribution to implants and bone tissue. The clinical implication of the augmented bone support loss after maxillectomy is the increase of stress in the attachment systems and, consequently, a higher tendency for displacement of the prosthesis.

  17. Vaginal toxic shock reaction triggering desquamative inflammatory vaginitis.

    PubMed

    Pereira, Nigel; Edlind, Thomas D; Schlievert, Patrick M; Nyirjesy, Paul

    2013-01-01

    The study aimed to report 2 cases of desquamative inflammatory vaginitis associated with toxic shock syndrome toxin 1 (TSST-1)-producing Staphylococcus aureus strains. Case report of 2 patients, 1 with an acute and 1 with a chronic presentation, diagnosed with desquamative inflammatory vaginitis on the basis of clinical findings and wet mount microscopy. Pretreatment and posttreatment vaginal bacterial and yeast cultures were obtained. Pretreatment vaginal bacterial cultures from both patients grew TSST-1-producing S. aureus. Subsequent vaginal bacterial culture results after oral antibiotic therapy were negative. Desquamative inflammatory vaginitis may be triggered through TSST-1-mediated vaginal toxic shock reaction.

  18. A hollow definitive obturator fabrication technique for management of partial maxillectomy.

    PubMed

    Patil, Pravinkumar Gajanan; Patil, Smita Pravinkumar

    2012-11-01

    Maxillary obturator prosthesis is the most frequent treatment option for management of partial or total maxillectomy. Heavy weight of the obturators is often a dislocating factor. Hollowing the prosthesis to reduce its weight is the well established fact. The alternate technique to hollow-out the prosthesis has been described in this article which is a variation of previously described processing techniques. A pre-shaped wax-bolus was incorporated inside the flasks during packing of the heat-polymerized acrylic resin to automatically create the hollow space. The processing technique described is a single step flasking procedure to construct a closed-hollow-obturator prosthesis as a single unit. To best understand the technique, this article describes management of a patient who had undergone partial maxillectomy secondary to squamous cell carcinoma rehabilitated with a hollow-obturator prosthesis.

  19. A hollow definitive obturator fabrication technique for management of partial maxillectomy

    PubMed Central

    Patil, Smita Pravinkumar

    2012-01-01

    Maxillary obturator prosthesis is the most frequent treatment option for management of partial or total maxillectomy. Heavy weight of the obturators is often a dislocating factor. Hollowing the prosthesis to reduce its weight is the well established fact. The alternate technique to hollow-out the prosthesis has been described in this article which is a variation of previously described processing techniques. A pre-shaped wax-bolus was incorporated inside the flasks during packing of the heat-polymerized acrylic resin to automatically create the hollow space. The processing technique described is a single step flasking procedure to construct a closed-hollow-obturator prosthesis as a single unit. To best understand the technique, this article describes management of a patient who had undergone partial maxillectomy secondary to squamous cell carcinoma rehabilitated with a hollow-obturator prosthesis. PMID:23236579

  20. Vaginal drug distribution modeling.

    PubMed

    Katz, David F; Yuan, Andrew; Gao, Yajing

    2015-09-15

    This review presents and applies fundamental mass transport theory describing the diffusion and convection driven mass transport of drugs to the vaginal environment. It considers sources of variability in the predictions of the models. It illustrates use of model predictions of microbicide drug concentration distribution (pharmacokinetics) to gain insights about drug effectiveness in preventing HIV infection (pharmacodynamics). The modeling compares vaginal drug distributions after different gel dosage regimens, and it evaluates consequences of changes in gel viscosity due to aging. It compares vaginal mucosal concentration distributions of drugs delivered by gels vs. intravaginal rings. Finally, the modeling approach is used to compare vaginal drug distributions across species with differing vaginal dimensions. Deterministic models of drug mass transport into and throughout the vaginal environment can provide critical insights about the mechanisms and determinants of such transport. This knowledge, and the methodology that obtains it, can be applied and translated to multiple applications, involving the scientific underpinnings of vaginal drug distribution and the performance evaluation and design of products, and their dosage regimens, that achieve it. Copyright © 2015 Elsevier B.V. All rights reserved.

  1. Vaginal Cancer—Patient Version

    Cancer.gov

    Two-thirds of vaginal cancer cases are caused by human papillomavirus (HPV). Vaccines that protect against infection with HPV may reduce the risk of vaginal cancer. When found early, vaginal cancer can often be cured. Start here to find information on vaginal cancer treatment and research.

  2. Obturator mononeuropathy caused by lipomatosis of the nerve: a case report.

    PubMed

    Nardone, Raffaele; Venturi, Alessandro; Ladurner, Gunther; Golaszewski, Stefan; Psenner, Konrad; Tezzon, Frediano

    2008-08-01

    We report a patient who presented with the clinical features of obturator mononeuropathy. Abdomino-pelvic computed tomography revealed a fusiform mass in the right perivesical space; magnetic resonance imaging (MRI) showed characteristic "coaxial-cable-like" appearance in cross-section and "spaghetti-like" appearance in longitudinal section, pathognomonic of lipomatosis of the nerve. Nerve lipomatosis as the cause of obturator neuropathy has not been previously reported. MRI provides definite and graphic proof of the diagnosis.

  3. Comparison of two vertical condensation obturation techniques: Touch 'n Heat modified and System B.

    PubMed

    Silver, G K; Love, R M; Purton, D G

    1999-08-01

    The aims of this study were firstly to compare the area of canal occupied by gutta-percha, sealer or voids using the System B heating device with that obtained by a modified vertical condensation technique using the Touch 'n Heat: and secondly to compare the temperature changes at the root canal wall and external root surface during obturation with the above techniques. Forty-five resin blocks, each with a standardized, simulated, prepared main root canal and five lateral canals, were assigned to three equal experimental groups. The canals were obturated using either the System B technique at two different temperature settings, or vertical condensation with a Touch 'n Heat instrument as the heat source. A heat transfer model was used to simultaneously record internal and external root surface temperature elevations during obturation by the three techniques. Data were analysed using unpaired Student's t-test and Mann-Whitney U-test. Both obturation techniques produced root fillings consisting of over 90% gutta-percha at most levels, although the percentages of sealer and voids 2-3 mm from the working length following System B obturation were higher than those found following modified vertical condensation. Modified vertical condensation resulted in more gutta-percha in lateral canals. Obturation was accomplished more quickly using the System B, and temperature elevations produced during obturation with the System B were significantly less (P < 0.001) than with vertical condensation. An elevation of external root surface temperature by more than 10 degrees C occurred during vertical condensation. The results suggest that the System B may produce an acceptable obturation and that the use of a Touch 'n Heat source during vertical condensation may result in damage to the periodontium.

  4. Comparison of different obturation techniques for primary molars by digital radiography.

    PubMed

    Memarpour, Mahtab; Shahidi, Shoaleh; Meshki, Razieh

    2013-01-01

    The purpose of this study was to compare six methods of root canal filling in primary mandibular second molars via digital radiography. A total of 239 canals were prepared and obturated with zinc-oxide eugenol paste. Obturation methods compared were: anesthetic syringe; NaviTip syringe; pressure syringe; tuberculin syringe; lentulo spiral; and packing with a plugger. The canals were evaluated in photostimulated phosphor radiographs for length of obturation, presence of voids, and number and sum of void sizes. The data were analyzed using chi-square, Kruskal-Wallis and Mann-Whitney tests. There were significant differences between all groups in the length of obturation (P>.01) and presence of voids (P<.001). The lentulo and tuberculin syringe groups, respectively, showed the best and worst results for length of obturation. Significant differences were also found in the number of voids (P<.001) and mean sum of void sizes in the coronal (P<.001) and middle third (P=.003). For the number and size of the voids, the NaviTip group showed the best results. Lentulo produced the best results in terms of length of obturation, while NaviTip syringe produced the best results in controlling paste extrusion from the apical foramen and having the smallest void size and lowest number of voids.

  5. Successful Treatment of Gluteal Pain from Obturator Internus Tendinitis and Bursitis with Ultrasound-Guided Injection.

    PubMed

    Chen, Boqing; Rispoli, Leia; Stitik, Todd; Leong, Michelle

    2017-10-01

    This case report describes what the authors believe is the first case of a patient with obturator internus tendinitis and bursitis successfully treated with a corticosteroid injection using a trans-tendinous lateral to medial approach. The patient presented with right gluteal pain not relieved by physical therapy or right hip and ischial bursa corticosteroid injections. Pelvic and lumbar spine MRIs and EMG/NCS findings were unremarkable. Physical examination demonstrated tenderness to palpation at the right middle lower gluteal region. Ultrasound imaging with sonopalpation identified the maximal local tender point as the right obturator internus muscle and/or its underlying bursa. A 22-gauge 3.5-inch needle was inserted in-plane to the transducer and longitudinal to the obturator internus from a lateral to medial direction, an approach previously described in cadavers. The obturator internus tendon sheath and bursa were injected with 2.5 ml of 0.5% lidocaine combined with 10 mg of triamcinolone. The patient reported immediate complete relief of pain with continued relief at 2 and 6 months post-injection. This case report demonstrates an injection of the obturator internus tendon sheath and bursa using a trans-tendinous approach, which may be successful for treatment of patients presenting with persistent gluteal pain from obturator internus tendinitis and bursitis.

  6. [MORPHOLOGICAL CHANGES OF THE LIVER IN OBTURATION JAUNDICE, CAUSED BY CHOLEDOCHOLITHIASIS, DEPENDING ON ITS DURATION].

    PubMed

    Sipliviy, V A; Yevtushenko, D V; Naumova, O V; Andreyeshchev, S A; Yevtushenko, A V

    2016-02-01

    Abstract The results of surgical treatment of 184 patients for obturation jaundice, caused by choledocholithiasis, were analyzed. Morphological changes of the liver were studied in 20 patients. There were three groups of patients delineated, depending on the obturation jaundice duration: up to 7 days, from 8 to 14 days, more than 15 days, and also a group of patients after the bile outflow restoration. The obturation jaundice occurrence in choledocholithiasis is accompanied by significant morphological changes in the liver, severity of which is enhancing while the obturation jaundice persistence increasing. While persistence of obturation jaundice through 8 days and more the connective tissue volume is enhancing, a relative volume of hepatocytes is reducing and a stromal-parenchymatous index is increasing. The bile outflow restoration secures significant reduction of intensity of alterative and inflammatory changes in hepatic parenchyma, as well as activation of reparative processes in the tissue. In cholangitis, caused by P. aeruginosa and E. coli, according to morphological investigations data, in the liver a diffuse purulent cholangitis on background of chronic changes in accordance to duration of the obturation jaundice persists.

  7. Clinical Assessment of Various Obturating Techniques for Primary Teeth: A Comparative Study

    PubMed Central

    Tandon, Sandeep; Vijay, Akshat; Kalia, Garima; Rathore, Khushboo

    2017-01-01

    Introduction Lifelong preservation of tooth in a healthy state is the ultimate goal of dentistry. Premature loss of primary teeth is common due to caries, dental trauma or other causes. As the primary teeth are the best space maintainers, teeth with infected pulps should be retained until exfoliation, whenever possible. Aim The purpose of this in vivo study was to evaluate and compare the efficacy of different obturating methods used in primary teeth. Materials and Methods Forty one patients aged four to nine years with a total of 60 teeth were selected. Out of the 60 teeth, 32 were primary mandibular first molars and 28 were primary mandibular second molars, the sample was randomly divided into three groups. Disposable syringe, lentulo spiral and past inject were used for obturation. Postoperative evaluation was done for; quality of canal obturation, presence of voids using postoperative radiographs following obturation of teeth. The data were analysed to assess the success rate of the three methods used for obturation using Chi-square test. Results Among the three groups of the study, past inject exhibited the maximum number of optimally filled canals. Maximum number of underfilled canals was found with lentulospiral, and the maximum number of overfilled canals was seen with disposable syringe. Least number of voids was observed in canals filled with the past inject technique and disposable syringe. Conclusion The results suggest that the most successful technique for obturation of primary teeth was past inject. PMID:28893042

  8. Tape functionality: position, change in shape, and outcome after TVT procedure--mid-term results.

    PubMed

    Kociszewski, Jacek; Rautenberg, Oliver; Kolben, Sebastian; Eberhard, Jakob; Hilgers, Reinhard; Viereck, Volker

    2010-07-01

    This study evaluates the relevance of the tape position and change in shape (tape functionality) under in vivo conditions for mid-term outcome. Changes in the sonographic tension-free vaginal tape (TVT) position relative to the percentage urethral length and the tape-urethra distance were determined after 6 and 48 months in 41 women with stress urinary incontinence. At 48 months, 76% (31/41) of women were cured, 17% (7/41) were improved, and 7% (3/41) were failures. Disturbed bladder voiding was present in 12% (5/41), de novo urge incontinence in 7% (3/41). The median TVT position was at 63% of urethral length. Median tape-urethra distance was 2.7 mm, ranging from 2.9 mm in continent patients without complications to 1.1 mm in those with obstructive complications. Patients with postoperative urine loss had a median distance of 3.9 mm. The tape was stretched at rest and C-shaped during straining in 15 of 41 women (37%) at 48 months (all continent). Patients with this tape functionality at 6 months were also cured at 48 months in 86% of cases (19/22), and only 14% (3/22) showed recurrent incontinence. Mid-term data suggest an optimal outcome if the tape is positioned at least 2 mm from the urethra at the junction of the middle and distal thirds. Patients with optimal tape functionality at 6 months are likely to show mid-term therapeutic success.

  9. Quick-release medical tape

    PubMed Central

    Laulicht, Bryan; Langer, Robert; Karp, Jeffrey M.

    2012-01-01

    Medical tape that provides secure fixation of life-sustaining and -monitoring devices with quick, easy, damage-free removal represents a longstanding unmet medical need in neonatal care. During removal of current medical tapes, crack propagation occurs at the adhesive–skin interface, which is also the interface responsible for device fixation. By designing quick-release medical tape to undergo crack propagation between the backing and adhesive layers, we decouple removal and device fixation, enabling dual functionality. We created an ordered adhesive/antiadhesive composite intermediary layer between the medical tape backing and adhesive for which we achieve tunable peel removal force, while maintaining high shear adhesion to secure medical devices. We elucidate the relationship between the spatial ordering of adhesive and antiadhesive regions to create a fully tunable system that achieves strong device fixation and quick, easy, damage-free device removal. We also described ways of neutralizing the residual adhesive on the skin and have observed that thick continuous films of adhesive are easier to remove than the thin islands associated with residual adhesive left by current medical tapes. PMID:23112196

  10. Vaginal delivery - discharge

    MedlinePlus

    ... slowly. Get plenty of rest. You can start sexual activity around 6 weeks after delivery, if the discharge or lochia has stopped. Women who breastfeed may have a lower sex drive than normal, along with vaginal dryness and pain ...

  11. Stages of Vaginal Cancer

    MedlinePlus

    ... stage of the cancer being treated. External and internal radiation therapy are used to treat vaginal cancer, and may also be used as palliative therapy to relieve symptoms and improve quality of life . Chemotherapy Chemotherapy is a cancer treatment ...

  12. Vaginitis - self-care

    MedlinePlus

    Vulvovaginitis - self-care; Yeast infections - vaginitis ... Creams or suppositories are used to treat yeast infections in the vagina. You can buy most of them without a prescription at drug stores, some grocery stores, and other stores. Treating yourself ...

  13. Vaginal Yeast Infections

    MedlinePlus

    ... for sure if yogurt with Lactobacillus or other probiotics can prevent or treat vaginal yeast infections. If ... Chen, H., et al. (2013). Impact of eating probiotic yogurt on colonization by Candida species of the ...

  14. Review of Vaginitis

    PubMed Central

    1993-01-01

    Adisruption of the dynamic equilibrium of the healthy vagina may have significant sequelae, leading to chronic or serious conditions. Therefore, all cases of vaginitis should be accurately diagnosed and appropriately treated. PMID:18475337

  15. Vaginal Yeast Infections

    MedlinePlus

    ... may feel more comfortable if you wear breathable cotton underwear and clothes and avoid vaginal sprays and ... help avoid them, follow your doctor's advice, wear cotton underwear, and try to wear loose-fitting clothes. ...

  16. Vaginal dryness alternative treatments

    MedlinePlus

    ... JE, Murray MT, eds. Textbook of Natural Medicine . 4th ed. St Louis, MO: Elsevier Churchill Livingstone; 2013: ... Vaginal dryness. In: Rakel D, ed. Integrative Medicine . 4th ed. Philadelphia, PA: Elsevier; 2018:chap 59.

  17. Evaluation of vaginal complaints.

    PubMed

    Anderson, Matthew R; Klink, Kathleen; Cohrssen, Andreas

    2004-03-17

    Vaginal symptoms are one of the most common reasons for gynecological consultation. Clinicians have traditionally diagnosed vaginal candidiasis, bacterial vaginosis, and vaginal trichomoniasis using some combination of physical examination, pH, the wet mount, and the whiff test. To evaluate the role of the clinical examination and determine the positive and negative likelihood ratios (LRs) for the diagnosis of vaginal candidiasis, bacterial vaginosis, and vaginal trichomoniasis. Using a structured literature review, we abstracted information on sensitivity and specificity for symptoms, signs, and office laboratory procedures. We chose published (1966 to April 2003) articles that appeared in the MEDLINE database and were indexed under the combined search terms of diagnosis with vaginitis, vaginal discharge, candidiasis, bacterial vaginosis, and trichomoniasis. Included studies of symptomatic premenopausal women seen in primary care settings. Tests were evaluated only if they would provide diagnostic information during the office visit and were compared with an acceptable criterion standard. All 3 authors extracted the data and computed sensitivity and specificity from each article independently. The absence of standard definitions for symptoms and signs made it impossible to combine results across studies. Symptoms alone do not allow clinicians to distinguish confidently between the causes of vaginitis. However, a patient's lack of itching makes candidiasis less likely (range of LRs, 0.18 [95% confidence interval [CI], 0.05-0.70] to 0.79 [95% CI, 0.72-0.87]) and lack of perceived odor makes bacterial vaginosis unlikely (LR, 0.07 [95% CI, 0.01-0.51]). Similarly, physical examination signs are limited in their diagnostic power. The presence of inflammatory signs is associated with candidiasis (range of LRs, 2.1 [95% CI, 1.5-2.8] to 8.4 [95% CI, 2.3-31]). Presence of a "high cheese" odor on examination is predictive of bacterial vaginosis (LR, 3.2 [95% CI, 2

  18. Fast track vaginal surgery.

    PubMed

    Ottesen, Marianne; Sørensen, Mette; Rasmussen, Yvonne; Smidt-Jensen, Steen; Kehlet, Henrik; Ottesen, Bent

    2002-02-01

    Our aim was to describe the need for postoperative hospitalization after vaginal surgery for utero-vaginal prolapse with well-defined charts for postoperative care. A prospective, descriptive study. Consecutive women admitted for first-time vaginal surgery for utero-vaginal prolapse at a public university hospital in Copenhagen, Denmark, underwent surgery and postoperative care in a fast track setting from September 15, 1999 to June 15 2000. A multimodal rehabilitation model with emphasis on information, standardized general anesthesia, reduced surgical distress, optimized pain-relief, early oral nutrition and ambulation, minimal use of indwelling catheter and vaginal packing. Postoperative hospital stay, complications, re-admission, success rate, patients' satisfaction and acceptability. Forty-one women with a median age of 69 years (range, 44-88 years) were included. All underwent anterior and/or posterior vaginal repair. Nineteen (46.3%) underwent vaginal hysterectomy, and eight (19.5%) underwent the Manchester procedure. Postoperative hospital stay was median 24 hr. Only three (7.3%) were discharged later than 48 hr. No re-admissions occurred. The most frequent complications were urinary retention exceeding 450 ml, and urinary tract infection (12.2%, and 9.8%, respectively). Short-term success rate was 97.6%. Patients' satisfaction rates were 85.4-95.1%. The median score of acceptability was 10 on a 0-10 points scale. The need for postoperative hospitalization was median 24 hr after vaginal surgery in a fast track setting, independently of the complexity of the procedure performed. Short-term success rate, satisfaction rates, and acceptability were all excellent. Follow up has been established to evaluate long-term success rates and recurrence.

  19. Personal miniature electrophysiological tape recorder

    NASA Astrophysics Data System (ADS)

    Green, H.

    1981-11-01

    The use of a personal miniature electrophysiological tape recorder to measure the physiological reactions of space flight personnel to space flight stress and weightlessness is described. The Oxford Instruments Medilog recorder, a battery-powered, four-channel cassette tape recorder with 24 hour endurance is carried on the person and will record EKG, EOG, EEG, and timing and event markers. The data will give information about heart rate and morphology changes, and document adaptation to zero gravity on the part of subjects who, unlike highly trained astronauts, are more representative of the normal population than were the subjects of previous space flight studies.

  20. Superconducting flat tape cable magnet

    DOEpatents

    Takayasu, Makoto

    2015-08-11

    A method for winding a coil magnet with the stacked tape cables, and a coil so wound. The winding process is controlled and various shape coils can be wound by twisting about the longitudinal axis of the cable and bending following the easy bend direction during winding, so that sharp local bending can be obtained by adjusting the twist pitch. Stack-tape cable is twisted while being wound, instead of being twisted in a straight configuration and then wound. In certain embodiments, the straight length should be half of the cable twist-pitch or a multiple of it.

  1. Fully synthetic taped insulation cables

    DOEpatents

    Forsyth, E.B.; Muller, A.C.

    1983-07-15

    The present invention is a cable which, although constructed from inexpensive polyolefin tapes and using typical impregnating oils, furnishes high voltage capability up to 765 kV, and has such excellent dielectric characteristics and heat transfer properties that it is capable of operation at capacities equal to or higher than presently available cables at a given voltage. This is accomplished by using polyethylene, polybutene or polypropylene insulating tape which has been specially processed to attain properties which are not generally found in these materials, but are required for their use in impregnated electrical cables. Chief among these properties is compatibility with impregnating oil.

  2. RESIDUAL RISK ASSESSMENT: MAGNETIC TAPE ...

    EPA Pesticide Factsheets

    This document describes the residual risk assessment for the Magnetic Tape Manufacturing source category. For stationary sources, section 112 (f) of the Clean Air Act requires EPA to assess risks to human health and the environment following implementation of technology-based control standards. If these technology-based control standards do not provide an ample margin of safety, then EPA is required to promulgate addtional standards. This document describes the methodology and results of the residual risk assessment performed for the Magnetic Tape Manufacturing source category. The results of this analyiss will assist EPA in determining whether a residual risk rule for this source category is appropriate.

  3. Applying extrusive orthodontic force without compromising the obturated canal space.

    PubMed

    Keinan, David; Szwec, Jerard; Matas, Avital; Moshonov, Joshua; Yitschaky, Oded

    2013-08-01

    Complicated tooth fractures can be the unfortunate result of orofacial trauma and can offer a therapeutic challenge for the dentist. A conservative solution for gaining supragingival sound tooth structure often includes orthodontic forced eruption. Usually, this procedure is carried out by applying extrusive force after placing a provisional acrylic Richmond crown on the tooth. However, this long-lasting dental treatment may jeopardize the coronal seal of the root canal space, leading to microleakage and endodontic failure. Orthodontic forced eruption demands application of force to an attachment connected to the remaining short clinical crown. In this article, the authors describe a case in which they used a new technique for orthodontic forced eruption of a traumatized tooth, using an extracanal attachment to apply extrusion force, and discuss its possible advantages and limitations. An extracanal attachment approach for orthodontic forced eruption without compromising the obturated canal space can be a solution for posttraumatic crown fracture. Practical Implications. The described procedure for forced eruption by using an extracanal pin attachment is efficient and convenient and does not require the clinician to apply force directly to the provisional crown. Therefore, during the application of force, there is less risk of loosening the provisional crown, and the canal space is kept intact with either the final restoration or dressing material.

  4. Scan converting video tape recorder

    NASA Technical Reports Server (NTRS)

    Holt, N. I. (Inventor)

    1971-01-01

    A video tape recorder is disclosed of sufficient bandwidth to record monochrome television signals or standard NTSC field sequential color at current European and American standards. The system includes scan conversion means for instantaneous playback at scanning standards different from those at which the recording is being made.

  5. The Goddard helical tape recorder

    NASA Technical Reports Server (NTRS)

    Martin, F. T.; Mccarthy, D. K.

    1972-01-01

    A spacecraft recorder was developed with the objective of functioning continuously for 5 years. The resulting design employed a metallic tape wound in a 200-turn helix. A direct drive, brushless dc torquer and servo speed control drove the recorder at 3 rpm for recording and 54 rpm for playback.

  6. Enhancing contrast of fingerprints on plastic tape.

    PubMed

    Steele, Charles A; Ball, Mikki S

    2003-11-01

    Many of the currently available fingerprinting methods have limited ability to visualize fingerprints on plastic tape without expensive equipment or significant handling of the sample. This is especially true for visualizing fingerprints on black electrical tape. This study sought a hands-off method to produce easy visualization of fingerprints on different types of plastic tape, including black electrical tape, without the need for expensive equipment. The methods selected were to sublime disperse dyes into the tape, both with and without the fuming of cyanoacrylate, everywhere except for where the fingerprint was applied. The resulting color contrasts provided enough differentiation to visualize fingerprints on plastic tape under ambient light. Sequential fuming with cyanoacrylate followed by disperse dyes provided the best visualizations on all tapes, and cyanoacrylate followed by disperse yellow 211 clearly visualized fingerprints on black electrical tape.

  7. EROS to universal tape conversion processor

    NASA Technical Reports Server (NTRS)

    Obrien, S. O. (Principal Investigator)

    1980-01-01

    The function of the EROS processor is to allow a user to select a specific area from a full frame LANDSAT image which is written on tape in the EROS format. The area of interest is read from the EROS formatted tape and converted to the JSC Universal format and written onto another tape. This tape can then be read by the IMDACS processing system and normal analysis can be performed.

  8. Vaginal Cancer—Health Professional Version

    Cancer.gov

    Vaginal cancer is often squamous cell carcinoma. Other types of vaginal cancer are adenocarcinoma, melanoma, and sarcoma. Infection with certain types of human papillomavirus (HPV) causes most vaginal cancer. Find evidence-based information on vaginal cancer treatment and research.

  9. High density tape/head interface study

    NASA Technical Reports Server (NTRS)

    Csengery, L. C.

    1983-01-01

    The high energy (H sub c approximately or = to 650 oersteds) tapes and high track density (84 tracks per inch) heads investigated had, as its goal, the definition of optimum combinations of head and tape, including the control required of their interfacial dynamics that would enable the manufacture of high rate (150 Mbps) digital tape recorders for unattended space flight.

  10. A comparative In vivo efficacy of three spiral techniques versus incremental technique in obturating primary teeth.

    PubMed

    Chandrasekhar, Shalini; Prasad, Madu Ghanashyam; Radhakrishna, Ambati Naga; Saujanya, Kaniti; Raviteja, N V K; Deepthi, B; Ramakrishna, J

    2018-01-01

    The aim of this study was to evaluate the efficiency of four different obturating techniques in filling the radicular space in primary teeth. This clinical trial was carried out on 34 healthy, cooperative children (5-9 years) who had 63 carious primary teeth indicated for pulpectomy. They were divided into four groups, such that in each group, a total of 40 canals were allotted for obturation with respective technique. The root canals of selected primary teeth were filled with Endoflas obturating material using either bi-directional spiral (Group 1); incremental technique (Group 2), past inject (Group 3) or lentulo spiral (Group 4) according to the groups assigned. The effectiveness of the obturation techniques was assessed using postoperative radiographs. The assessment was made for a depth of fill in the canal, the presence of any voids using Modified Coll and Sadrian criteria. The obtained data were analyzed by using ANOVA test and unpaired t-test. Bi-directional spiral and lentulo spiral were superior to other techniques in providing optimally filled canals (P< 0.05). The bi-directional spiral was superior to lentulo spiral in preventing overfill (P< 0.05). Based on the present study results, bi-directional spiral can be recommended as an alternate obturating technique in primary teeth.

  11. Microgap Evaluation of Novel Hydrophilic and Hydrophobic Obturating System: A Scanning Electron Microscope Study.

    PubMed

    Hegde, Vibha; Murkey, Laxmi Suresh

    2017-05-01

    The purpose of an endodontic obturation is to obtain a fluid tight hermetic seal of the entire root canal system. There has been an evolution of different materials and techniques to achieve this desired gap free fluid tight seal due to presence of anatomic complexity of the root canal system. To compare the microgap occurring in root canals obturated with hydrophilic versus hydrophobic systems using scanning electron microscope. Sixty extracted human single-rooted premolars were decoronated, instrumented using NiTi rotary instruments. The samples (n=20) were divided into three groups and obturated with Group A - (control group) gutta-percha with AH Plus, Group B - C-point with Smartpaste Bio and Group C - gutta-percha with guttaflow 2. The samples were split longitudinally into two halves and microgap was observed under scanning electron microscope in the apical 3 mm of the root canal. Group A (control) showed a mean difference of 8.54 as compared to 5.76 in group C. Group B showed the lowest mean difference of 0.83 suggesting that the hydrophilic system (C-point/Smartpaste Bio) produced least microgap as compared to the hydrophobic groups. Novel hydrophilic obturating system (C-points/ Smart-paste Bio) showed better seal and least microgap as compared to gutta-percha/guttaflow 2 and gutta-percha/ AH plus which showed gap at the sealer dentin interface due to less penetration and bonding of these hydrophobic obturating system.

  12. Gemelli-obturator complex in the deep gluteal space: an anatomic and dynamic study.

    PubMed

    Balius, Ramon; Susín, Antonio; Morros, Carles; Pujol, Montse; Pérez-Cuenca, Dolores; Sala-Blanch, Xavier

    2018-06-01

    To investigate the behavior of the sciatic nerve during hip rotation at subgluteal space. Sonographic examination (high-resolution ultrasound machine at 5.0-14 MHZ) of the gemelli-obturator internus complex following two approaches: (1) a study on cadavers and (2) a study on healthy volunteers. The cadavers were examined in pronation, pelvis-fixed position by forcing internal and external rotations of the hip with the knee in 90° flexion. Healthy volunteers were examined during passive internal and external hip rotation (prone position; lumbar and pelvic regions fixed). Subjects with a history of major trauma, surgery or pathologies affecting the examined regions were excluded. The analysis included eight hemipelvis from six fresh cadavers and 31 healthy volunteers. The anatomical study revealed the presence of connective tissue attaching the sciatic nerve to the structures of the gemellus-obturator system at deep subgluteal space. The amplitude of the nerve curvature during rotating position was significantly greater than during resting position. During passive internal rotation, the sciatic nerve of both cadavers and healthy volunteers transformed from a straight structure to a curved structure tethered at two points as the tendon of the obturator internus contracted downwards. Conversely, external hip rotation caused the nerve to relax. Anatomically, the sciatic nerve is closely related to the gemelli-obturator internus complex. This relationship results in a reproducible dynamic behavior of the sciatic nerve during passive hip rotation, which may contribute to explain the pathological mechanisms of the obturator internal gemellus syndrome.

  13. Analysis of cache for streaming tape drive

    NASA Technical Reports Server (NTRS)

    Chinnaswamy, V.

    1993-01-01

    A tape subsystem consists of a controller and a tape drive. Tapes are used for backup, data interchange, and software distribution. The backup operation is addressed. During a backup operation, data is read from disk, processed in CPU, and then sent to tape. The processing speeds of a disk subsystem, CPU, and a tape subsystem are likely to be different. A powerful CPU can read data from a fast disk, process it, and supply the data to the tape subsystem at a faster rate than the tape subsystem can handle. On the other hand, a slow disk drive and a slow CPU may not be able to supply data fast enough to keep a tape drive busy all the time. The backup process may supply data to tape drive in bursts. Each burst may be followed by an idle period. Depending on the nature of the file distribution in the disk, the input stream to the tape subsystem may vary significantly during backup. To compensate for these differences and optimize the utilization of a tape subsystem, a cache or buffer is introduced in the tape controller. Most of the tape drives today are streaming tape drives. A streaming tape drive goes into reposition when there is no data from the controller. Once the drive goes into reposition, the controller can receive data, but it cannot supply data to the tape drive until the drive completes its reposition. A controller can also receive data from the host and send data to the tape drive at the same time. The relationship of cache size, host transfer rate, drive transfer rate, reposition, and ramp up times for optimal performance of the tape subsystem are investigated. Formulas developed will also show the advantages of cache watermarks to increase the streaming time of the tape drive, maximum loss due to insufficient cache, tradeoffs between cache and reposition times and the effectiveness of cache on a streaming tape drive due to idle times or interruptions due in host transfers. Several mathematical formulas are developed to predict the performance of the tape

  14. Aerobic vaginitis in pregnancy.

    PubMed

    Donders, Ggg; Bellen, G; Rezeberga, D

    2011-09-01

    Aerobic vaginitis (AV) is an alteration in vaginal bacterial flora that differs from bacterial vaginosis (BV). AV is characterised by an abnormal vaginal microflora accompanied by an increased localised inflammatory reaction and immune response, as opposed to the suppressed immune response that is characteristic of BV. Given the increased local production of interleukin (IL)-1, IL-6 and IL-8 associated with AV during pregnancy, not surprisingly AV is associated with an increased risk of preterm delivery, chorioamnionitis and funisitis of the fetus. There is no consensus on the optimal treatment for AV in pregnant or non-pregnant women, but a broader spectrum drug such as clindamycin is preferred above metronidazole to prevent infection-related preterm birth. The exact role of AV in pregnancy, the potential benefit of screening, and the use of newer local antibiotics, disinfectants, probiotics and immune modulators need further study. © 2011 The Authors BJOG An International Journal of Obstetrics and Gynaecology © 2011 RCOG.

  15. STS-88 Mission Highlights Resources Tape. Tape B

    NASA Technical Reports Server (NTRS)

    1999-01-01

    The STS-88 flight crew, Commander Robert D. Cabana, Pilot Frederick W. Sturckow, and Mission Specialists Nancy J. Currie, James H. Newman, Jerry L. Ross, and Sergei Krikalev present a video overview of their space flight. Tape two of three includes the installation of an S-Band to help monitor the UNITY Connecting Module, the opening of UNITY's hatch, the opening of the main compartment hatch to ZARYA Control Module, and the repair of the inflight maintenance system.

  16. General Information about Vaginal Cancer

    MedlinePlus

    ... Research Vaginal Cancer Treatment (PDQ®)–Patient Version General Information About Vaginal Cancer Go to Health Professional Version ... the PDQ Adult Treatment Editorial Board . Clinical Trial Information A clinical trial is a study to answer ...

  17. Vaginal itching and discharge - child

    MedlinePlus

    ... vulvae; Itching - vaginal area; Vulvar itching; Yeast infection - child ... To prevent and treat vaginal irritation, your child should: Avoid colored or perfumed toilet tissue and bubble bath. Use plain, unscented soap. Limit bath time to 15 minutes or less. Ask ...

  18. Vaginal bleeding in late pregnancy

    MedlinePlus

    ... this page: //medlineplus.gov/ency/patientinstructions/000627.htm Vaginal bleeding in late pregnancy To use the sharing ... JavaScript. One out of 10 women will have vaginal bleeding during their 3rd trimester. At times, it ...

  19. Vaginal Toxic Shock Reaction Triggering Desquamative Inflammatory Vaginitis

    PubMed Central

    Pereira, Nigel; Edlind, Thomas D.; Schlievert, Patrick M.; Nyirjesy, Paul

    2012-01-01

    Objective To report two cases of desquamative inflammatory vaginitis (DIV) associated with toxic shock syndrome toxin-1 (TSST-1)-producing Staphylococcus aureus strains. Materials and Methods Case report of two patients, one with an acute and one with a chronic presentation, diagnosed with DIV on the basis of clinical findings and wet mount microscopy. Pre- and posttreatment vaginal bacterial and yeast cultures were obtained. Results Pretreatment vaginal bacterial cultures from both patients grew TSST-1-producing S. aureus. Subsequent vaginal bacterial cultures following oral antibiotic therapy were negative. Conclusions DIV may be triggered through TSST-1-mediated vaginal toxic shock reaction. PMID:23222054

  20. Primary obturator externus pyomyositis in a child presenting as hip pain: a case report.

    PubMed

    Kumar, Abhishek; Anderson, David

    2008-02-01

    Hip pain in children often poses a diagnostic dilemma. Septic arthritis, Perthes disease, and slipped capital femoral epiphysis are among the most important causes. Pyomyositis involving muscles around the hip can present with similar features as septic arthritis and are difficult to diagnose because of their rarity and indolent presentation. Obturator internus and iliopsoas muscle abscess have been most commonly reported, with only 1 such report on isolated obturator externus muscle abscess. Routine laboratory investigations are nonspecific, and the diagnosis rests on imaging modalities. Magnetic resonance scan is the most useful investigation in the diagnosis and can pick up early changes in the muscle. Treatment involves appropriate antibiotic therapy with or without drainage. Most cases resolve completely. We report here a case of isolated obturator externus muscle abscess in an 11-year-old child illustrating the similarities with septic arthritis of hip and problems encountered during diagnosis and management.

  1. Effect of tape recording on perturbation measures.

    PubMed

    Jiang, J; Lin, E; Hanson, D G

    1998-10-01

    Tape recorders have been shown to affect measures of voice perturbation. Few studies, however, have been conducted to quantitatively justify the use or exclusion of certain types of recorders in voice perturbation studies. This study used sinusoidal and triangular waves and synthesized vowels to compare perturbation measures extracted from directly digitized signals with those recorded and played back through various tape recorders, including 3 models of digital audio tape recorders, 2 models of analog audio cassette tape recorders, and 2 models of video tape recorders. Signal contamination for frequency perturbation values was found to be consistently minimal with digital recorders (percent jitter = 0.01%-0.02%), mildly increased with video recorders (0.05%-0.10%), moderately increased with a high-quality analog audio cassette tape recorder (0.15%), and most prominent with a low-quality analog audio cassette tape recorder (0.24%). Recorder effect on amplitude perturbation measures was lowest in digital recorders (percent shimmer = 0.09%-0.20%), mildly to moderately increased in video recorders and a high-quality analog audio cassette tape recorder (0.25%-0.45%), and most prominent in a low-quality analog audio cassette tape recorder (0.98%). The effect of cassette tape material, length of spooled tape, and duration of analysis were also tested and are discussed.

  2. Multilingual health education tapes project.

    PubMed

    Vryheid, R

    1992-01-01

    The success of Thailand's 1985 malaria education cassette tapes project motivated the Highland Development Program to produce tapes in 6 tribal languages on family planning, maternal and child health, nutrition, and disease prevention. Staff produced tapes using a drama or radio magazine format as a series of short features with music and sound effects. Scriptwriters consulted villagers, broadcasting professionals, research workers, and health officials to tailor messages to the various hill tribes. They tried to avoid conflict between traditional and modern concepts and to minimize distrust of government services. The scriptwriters used basically short, grammatically simple sentences, and colloquial Thai to simplify translation. The staff tried to recruit literate, adult, native speakers of the target languages with some experience in health education in their own languages. Obstacles encountered with translation included some languages used an uncommon alphabet or translators did not know their own alphabet. The program backtranslated the scripts to assure the accuracy of the messages and the appropriateness of the words used. Backtranslation revealed deficiencies in the translated messages. Altering the meaning of technical terms tended to be simple mistakes, words with multiple meanings, and exaggeration of problems and/or solutions. Translators also sometimes failed to adapt cultural ideas to those of their tribes. For example, some persons translated all possible misconceptions about a disease yet the tribes did not have all the misconceptions. As of early 1992, recording, pretesting, distribution, and follow up had not yet taken place. The staff should meet with a recording studio to coordinate production including technicians and translators identifying means to communicate. Staff should be aware of signs of poor translation which they may have missed earlier and surfaces during recording. Pretesting should occur among literate and illiterate members of

  3. Digital tape unit test facility software

    NASA Technical Reports Server (NTRS)

    Jackson, J. T.

    1971-01-01

    Two computer programs are described which are used for the collection and analysis of data from the digital tape unit test facility (DTUTF). The data are the recorded results of skew tests made on magnetic digital tapes which are used on computers as input/output media. The results of each tape test are keypunched onto an 80 column computer card. The format of the card is checked and the card image is stored on a master summary tape via the DTUTF card checking and tape updating system. The master summary tape containing the results of all the tape tests is then used for analysis as input to the DTUTF histogram generating system which produces a histogram of skew vs. date for selected data, followed by some statistical analysis of the data.

  4. Gluteo-vaginal fistula after posterior intravaginal slingplasty: a case report.

    PubMed

    Grynberg, Michael; Teyssedre, Jacques; Staerman, Frederic

    2009-07-01

    In patients with posthysterectomy prolapse of the vaginal vault, the posterior intravaginal slingplasty (posterior IVS, Tyco Healthcare, USA) has been suggested as an alternative to traditional vaginal vault suspensions. The goal of this technique is to recreate the uterosacral ligaments and to reinforce the rectovaginal fascia with the use of prosthetic material. We report the case of a 53-year-old woman with a history of 27 months of perineal suppurative discharge after she underwent a vaginal vault prolapse and rectocele repair using a posterior IVS (Tyco Healthcare, USA). The IVS tape was reinforced by interposing a rectovaginal monofilament polypropylene mesh (Parietex, Sofradim, France). Imaging studies and surgical exploration confirmed infection of the IVS mesh with the formation of a gluteo-vaginal fistula while the rectovaginal mesh was intact.

  5. Delayed vaginal and urethral mesh exposure: 10 years after TVT surgery.

    PubMed

    Khanuengkitkong, Siwatchaya; Lo, Tsia-Shu; Dass, Anil Krishna

    2013-03-01

    Delayed mesh exposure after tension-free vaginal tape (TVT) procedure is rare. We report a case of mesh exposure into the vagina and urethra that developed 10 years after TVT surgery. A 58-year-old postmenopausal woman presented with mixed urinary incontinence. She was investigated, and her stress urinary incontinence was cured with a TVT procedure 10 years ago. She was then scheduled follow-up annually. Two years postsurgery, a granulation tissue was observed and excised at the vaginal incision site. Vaginal examination 10 years postsurgery showed vaginal mesh erosion 0.5 cm from urethral meatus. Cystoscopy revealed concomitant urethral erosion at the posterior urethral wall. Mesh excision was performed, and urethra and vagina were repaired in layers. Postoperative recovery was uneventful. This finding shows that, although rare, complications can occur even after 10 years of TVT surgery.

  6. Non-specific vaginitis or vaginitis of undetermined aetiology.

    PubMed

    Faro, S; Phillips, L E

    1987-01-01

    Vaginitis is a complex syndrome that is probably the most common outpatient disease seen by the gynaecologist. The specific aetiologies of vaginitis are many. One of the most common entities, however, is "non-specific vaginitis" which can be subdivided into: Gardnerella vaginitis, anaerobic vaginosis, and vaginitis of undetermined aetiology. The role of Gardnerella as a causative agent for vaginitis has been studied in depth but its specific role remains controversial. Anaerobic vaginosis can be diagnosed by noting on microscopic examination the presence of clue cells, free-floating bacteria and numerous white blood cells (WBC's). Culturing an aliquot of the vaginal discharge reveals a high number of anaerobes. In addition, this condition responds to antibiotics effective against anaerobes, e.g., metronidazole. Vaginitis of undetermined aetiology is more complex and is characterized by a purulent vaginal discharge, a pH of 4.0-4.6, numerous WBC's, and a high concentration of bacteria. The microbiology of this vaginitis includes many facultative Gram-negative rods and Gram-positive cocci. Anaerobes may be present but do not make up a large component of the endogenous microflora. This condition does not respond to the usual antibiotic therapies employed in treating bacterial vaginitis. Since this condition appears to be primarily an inflammatory reaction, it may be responsive to topical antiinflammatory agents such as benzydamine.

  7. Digital terrain tapes: user guide

    USGS Publications Warehouse

    ,

    1980-01-01

    DMATC's digital terrain tapes are a by-product of the agency's efforts to streamline the production of raised-relief maps. In the early 1960's DMATC developed the Digital Graphics Recorder (DGR) system that introduced new digitizing techniques and processing methods into the field of three-dimensional mapping. The DGR system consisted of an automatic digitizing table and a computer system that recorded a grid of terrain elevations from traces of the contour lines on standard topographic maps. A sequence of computer accuracy checks was performed and then the elevations of grid points not intersected by contour lines were interpolated. The DGR system produced computer magnetic tapes which controlled the carving of plaster forms used to mold raised-relief maps. It was realized almost immediately that this relatively simple tool for carving plaster molds had enormous potential for storing, manipulating, and selectively displaying (either graphically or numerically) a vast number of terrain elevations. As the demand for the digital terrain tapes increased, DMATC began developing increasingly advanced digitizing systems and now operates the Digital Topographic Data Collection System (DTDCS). With DTDCS, two types of data elevations as contour lines and points, and stream and ridge lines are sorted, matched, and resorted to obtain a grid of elevation values for every 0.01 inch on each map (approximately 200 feet on the ground). Undefined points on the grid are found by either linear or or planar interpolation.

  8. Analysis of Vaginal Cell Populations during Experimental Vaginal Candidiasis

    PubMed Central

    Fidel, Paul L.; Luo, Wei; Steele, Chad; Chabain, Joseph; Baker, Marc; Wormley, Floyd

    1999-01-01

    Studies with an estrogen-dependent murine model of vaginal candidiasis suggest that local cell-mediated immunity (CMI) is more important than systemic CMI for protection against vaginitis. The present study, however, showed that, compared to uninfected mice, little to no change in the percentage or types of vaginal T cells occurred during a primary vaginal infection or during a secondary vaginal infection where partial protection was observed. Furthermore, depletion of polymorphonuclear leukocytes (PMN) had no effect on infection in the presence or absence of pseudoestrus. These results indicate a lack of demonstrable effects by systemic CMI or PMN against vaginitis and suggest that if local T cells are important, they are functioning without showing significant increases in numbers within the vaginal mucosa during infection. PMID:10338532

  9. In vitro resistance to fracture of roots obturated with Resilon or gutta-percha.

    PubMed

    Monteiro, Jeanne; de Ataide, Ida de Noronha; Chalakkal, Paul; Chandra, Pavan Kumar

    2011-06-01

    There have been varied results from studies comparing postendodontic fracture resistance between teeth obturated with Resilon or gutta-percha. This study was performed to evaluate the fracture resistance of roots obturated by using Resilon (RealSeal system) or gutta-percha (with AH Plus sealer). Eighty extracted human mandibular single-rooted premolars stored in 10% formalin were used in the study. They were prepared by using a crown-down technique, debrided with NaOCl, ethylenediaminetetraacetic acid, and sterile water and divided into 4 groups. Obturation was performed by using the lateral condensation method. The negative control group consisted of unfilled specimens, and the positive control group consisted of those obturated with flowable, dual-cure composite resin. All root specimens were stored for 2 weeks in 100% humidity to allow complete setting of the sealer. Each specimen was mounted in acrylic in a polyvinyl ring and tested for fracture resistance with the Universal testing machine. The loading fixture of the machine was mounted with its spherical tip aligned with the center of the canal opening of each root. A vertical loading force was applied until it fractured the root. The force values were subjected to statistical analysis including analysis of variance and Fisher least significant difference testing. Teeth obturated with Resilon were more resistant to fracture than those obturated with gutta-percha. The difference was found to be highly significant (P=.00001). Resilon increased the resistance to fracture of single-rooted teeth in vitro. Copyright © 2011 American Association of Endodontists. Published by Elsevier Inc. All rights reserved.

  10. Quality of Life in Patients After Maxillectomy and Placement of Prosthetic Obturator.

    PubMed

    Chen, Cheng; Ren, Wen-Hao; Huang, Rui-Zhe; Gao, Ling; Hu, Zhi-Ping; Zhang, Lin-Mei; Li, Shao-Ming; Dong, Kai; Qi, Hong; Zhi, Ke-Qian

    2016-01-01

    The aim of this study was to assess quality of life (QoL) and obturator functioning in patients having undergone a maxillectomy as a tumor ablative resection and rehabilitation with a prosthetic obturator. The University of Washington Quality of Life scale version 4 (UW-QoLv4) and the Obturator Functioning Scale (OFS) were used to evaluate the self-reported QoL and obturator functioning. The effects of demographic and treatment variables on QoL were assessed using age, defect size, postoperative radiotherapy (RT), neck dissection, and dentition. The study included 16 men and 13 women with a mean age of 48.8 years. Of the 29 patients, 16 had a Brown Class 2a or smaller defect and 13 had a Brown Class 2b or larger defect. The mean OFS score (P = .004) and the physical (P = .001) and social-emotional function scores (P = .001) of the patients who received postoperative RT were significantly lower than those who did not receive postoperative RT. The subscales for swallowing (P = .008), saliva (P = .001), pain (P = .001), and shoulder function (P = .002) correlated strongly with postoperative RT on the UW-QoL. The subscales for pronunciation (P = .007) and saliva (P = .002) correlated significantly with RT on the OFS. The mean OFS scores were significantly lower for the patients with a Brown Class 2a or smaller defect than for Brown Class 2b or larger (P = .005). Postoperative RT was the strongest variable affecting QoL in patients with maxillectomy and prosthetic obturator reconstruction. The size of the defect slightly influenced the obturator function; however, it did not influence the overall QoL.

  11. A simplified technique of orthograde MTA obturation on the elected canals of posterior teeth: Two case reports.

    PubMed

    Wahengbam, Brucelee; Wahengbam, Pragya; Tikku, Aseem Prakash

    2014-01-01

    This article suggests a simplified technique of orthograde MTA obturation in less accessible canal(s) of posteriors teeth without using costly ultrasonics or specialised carrier. Essentially few finger pluggers, absorbent points and a simple canal projection method were used. The orifice(s) of the elected canal(s) to be obturated with MTA were projected onto the external occlusal surface for easy delivery and predictive instrumentation. The idea was based on 'easy access', 'working one canal with one mix at one time', 'thorough condensation' and 'removal of excess moisture'. In case I, palatal canal of tooth no. 2 with gross apical perforation and suspected VRF was obturated with MTA. And in Case II, tooth no. 19 presented with incomplete furcal fracture extending into the canal was obturated with MTA in all 3 canals unitarily. Dense homogenous MTA obturation was achieved and both cases healed uneventfully.

  12. 41 CFR 101-26.508 - Electronic data processing (EDP) tape and instrumentation tape (wide and intermediate band).

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... processing (EDP) tape and instrumentation tape (wide and intermediate band). 101-26.508 Section 101-26.508... Programs § 101-26.508 Electronic data processing (EDP) tape and instrumentation tape (wide and intermediate band). Procurement by Federal agencies of EDP tape and instrumentation tape (wide and intermediate band...

  13. 41 CFR 101-26.508 - Electronic data processing (EDP) tape and instrumentation tape (wide and intermediate band).

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... processing (EDP) tape and instrumentation tape (wide and intermediate band). 101-26.508 Section 101-26.508... Programs § 101-26.508 Electronic data processing (EDP) tape and instrumentation tape (wide and intermediate band). Procurement by Federal agencies of EDP tape and instrumentation tape (wide and intermediate band...

  14. 41 CFR 101-26.508 - Electronic data processing (EDP) tape and instrumentation tape (wide and intermediate band).

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... processing (EDP) tape and instrumentation tape (wide and intermediate band). 101-26.508 Section 101-26.508... Programs § 101-26.508 Electronic data processing (EDP) tape and instrumentation tape (wide and intermediate band). Procurement by Federal agencies of EDP tape and instrumentation tape (wide and intermediate band...

  15. 41 CFR 101-26.508 - Electronic data processing (EDP) tape and instrumentation tape (wide and intermediate band).

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... processing (EDP) tape and instrumentation tape (wide and intermediate band). 101-26.508 Section 101-26.508... Programs § 101-26.508 Electronic data processing (EDP) tape and instrumentation tape (wide and intermediate band). Procurement by Federal agencies of EDP tape and instrumentation tape (wide and intermediate band...

  16. 41 CFR 101-26.508 - Electronic data processing (EDP) tape and instrumentation tape (wide and intermediate band).

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... processing (EDP) tape and instrumentation tape (wide and intermediate band). 101-26.508 Section 101-26.508... Programs § 101-26.508 Electronic data processing (EDP) tape and instrumentation tape (wide and intermediate band). Procurement by Federal agencies of EDP tape and instrumentation tape (wide and intermediate band...

  17. Echocardiographic demonstration of intracardiac glue after endoscopic obturation of gastroesophageal varices.

    PubMed

    Gallet, B; Zemour, G; Saudemont, J P; Renard, P; Hillion, M L; Hiltgen, M

    1995-01-01

    Systemic embolism is an unusual complication of endoscopic obturation of gastroesophageal varices with glue. This report describes a case of cerebral embolism after this procedure. Intracardiac glue within the left atrium was demonstrated by echocardiography. Cardiac fluoroscopy demonstrated an abnormal vessel connecting periesophageal veins with the right upper pulmonary vein. Cardiac surgery was performed. Intracardiac glue was removed and the entering orifice of the abnormal vessel in the right upper pulmonary vein was sutured. To our knowledge, this is the first reported case of intracardiac glue after variceal obturation. Echocardiography is useful in the diagnosis of this rare complication.

  18. Novel application of internal obturator and semitendinosus muscle flaps for rectal wall repair or reinforcement.

    PubMed

    Riggs, J; Ladlow, J F; Owen, L J; Hall, J L

    2018-01-29

    Internal obturator and/or semitendinosus muscle flaps were used to reinforce primary appositional rectal wall repair in three dogs and one cat in this case series. All three dogs incurred rectal wall compromise during surgical excision of anal sac tumours. The cat sustained bite wounds to the perianal region resulting in abscessation and a rectal tear. Our results indicate that application of an internal obturator and/or semitendinosus muscle flap can reduce the risk of rectal wall dehiscence after primary repair, and consequently the risk of pararectal abscess or rectocutaneous fistula formation. © 2018 British Small Animal Veterinary Association.

  19. Evaluation of a New Thermoplastic Gutta Percha Obturation Technique Using 45Ca.

    DTIC Science & Technology

    1980-10-27

    Codes A,’lzi 1 and/or D 1 Spoe 0, ’ -mi ll .. ., , N .... i I .. hl i Ii n . .. . .. INTRODUCTION In the development of endodontic therapy, many types...of filling material have been used for obturation.1-3 Various techniques of obturation have also been employed. In present day endodontic therapy, the...primary objectives of endodontic therapy.3 ,6𔄁 Various radioisotopes have been utilized to evaluate the adequacy of the apical seal. 8-13 One

  20. Closed hollow bulb obturator--one-step fabrication: a clinical report.

    PubMed

    Buzayan, Muaiyed M; Ariffin, Yusnidar T; Yunus, Norsiah

    2013-10-01

    A method is described for the fabrication of a closed hollow bulb obturator prosthesis using a hard thermoforming splint material and heat-cured acrylic resin. The technique allowed the thickness of the thermoformed bulb to be optimized for weight reduction, while the autopolymerized seal area was covered in heat-cured acrylic resin, thus eliminating potential leakage and discoloration. This technique permits the obturator prosthesis to be processed to completion from the wax trial denture without additional laboratory investing, flasking, and processing. © 2013 by the American College of Prosthodontists.

  1. Failed Operative Vaginal Delivery

    PubMed Central

    Alexander, James M.; Leveno, Kenneth J.; Hauth, John C.; Landon, Mark B.; Gilbert, Sharon; Spong, Catherine Y.; Varner, Michael W.; Caritis, Steve N.; Meis, Paul; Wapner, Ronald J.; Sorokin, Yoram; Miodovnik, Menachem; O'Sullivan, Mary J.; Sibai, Baha M.; Langer, Oded; Gabbe, Steven G.

    2010-01-01

    Objective To compare maternal and neonatal outcomes in women undergoing a second stage cesarean after a trial of operative vaginal delivery with women undergoing a second stage cesarean without such an attempt. Methods This study is a secondary analysis of the women who underwent second stage cesarean. .The maternal outcomes examined included blood transfusion, endometritis, wound complication, anesthesia use, and maternal death. Infant outcomes examined included umbilical artery pH < 7.0, Apgar of 3 or less at 5 minutes, seizures within 24 hours of birth, hypoxic ischemic encephalopathy (HIE), stillbirth, skull fracture, and neonatal death. Results Of 3189 women who underwent second stage cesarean, operative vaginal delivery was attempted in 640. Labor characteristics were similar in the two groups with the exception of the admission to delivery time and cesarean indication. Those with an attempted operative vaginal delivery were more likely to undergo cesarean delivery for a non-reassuring fetal heart rate tracing (18.0% vs 13.9%, p=.01), have a wound complication (2.7% vs 1.0%; OR 2.65 95% CI 1.43–4.91), and require general anesthesia (8.0% vs 4.1%, OR 2.05 95% CI 1.44–2.91). Neonatal outcomes including umbilical artery pH less than 7.0, Apgar at or below 3 at 5 minutes, and hypoxic ischemic encephalopathy were more common for those with an attempted operative vaginal delivery. This was not significant when cases with a non-reassuring fetal heart rate tracing were removed. Conclusion Cesarean delivery after an attempt at operative vaginal delivery was not associated with adverse neonatal outcomes in the absence of a non-reassuring fetal heart rate tracing. PMID:20168101

  2. Menopause and the vaginal microbiome.

    PubMed

    Muhleisen, Alicia L; Herbst-Kralovetz, Melissa M

    2016-09-01

    For over a century it has been well documented that bacteria in the vagina maintain vaginal homeostasis, and that an imbalance or dysbiosis may be associated with poor reproductive and gynecologic health outcomes. Vaginal microbiota are of particular significance to postmenopausal women and may have a profound effect on vulvovaginal atrophy, vaginal dryness, sexual health and overall quality of life. As molecular-based techniques have evolved, our understanding of the diversity and complexity of this bacterial community has expanded. The objective of this review is to compare the changes that have been identified in the vaginal microbiota of menopausal women, outline alterations in the microbiome associated with specific menopausal symptoms, and define how hormone replacement therapy impacts the vaginal microbiome and menopausal symptoms; it concludes by considering the potential of probiotics to reinstate vaginal homeostasis following menopause. This review details the studies that support the role of Lactobacillus species in maintaining vaginal homeostasis and how the vaginal microbiome structure in postmenopausal women changes with decreasing levels of circulating estrogen. In addition, the associated transformations in the microanatomical features of the vaginal epithelium that can lead to vaginal symptoms associated with menopause are described. Furthermore, hormone replacement therapy directly influences the dominance of Lactobacillus in the microbiota and can resolve vaginal symptoms. Oral and vaginal probiotics hold great promise and initial studies complement the findings of previous research efforts concerning menopause and the vaginal microbiome; however, additional trials are required to determine the efficacy of bacterial therapeutics to modulate or restore vaginal homeostasis. Copyright © 2016 Elsevier Ireland Ltd. All rights reserved.

  3. Hygroscopic properties of magnetic recording tape

    NASA Technical Reports Server (NTRS)

    Cuddihy, E. F.

    1976-01-01

    Relative humidity has been recognized as an important environmental factor in many head-tape interface phenomena such as headwear, friction, staining, and tape shed. Accordingly, the relative humidity is usually specified in many applications of tape use, especially when tape recorders are enclosed in hermetically sealed cases. Normally, the relative humidity is believed regulated by humidification of the fill gas to the specification relative humidity. This study demonstrates that the internal relative humidity in a sealed case is completely controlled by the time-dpendence of the hygroscopic properties of the pack of magnetic recording tape. Differences are found in the hygroscopic properties of the same brand of tape, which apparently result from aging, and which may have an effect on the long-term humidity-regulating behavior in a sealed case, and on the occurrence of head-tape interface phenomena from the long-term use of the tape. Results are presented on the basic hygroscopic properties of magnetic tape, its humidity-regulating behavior in a sealed case, and a theoretical commentary on the relative humidity dependence of head-wear by tape, is included.

  4. [Laryngeal Tube Position Shift after Chest Compression: Comparison of Fixation Methods Using Durapore Tape, Multipore Tape, or a Neck Tape].

    PubMed

    Seno, Hisayo; Komasawa, Nobuyasu; Fujiwara, Shunsuke; Miyazaki, Shinichiro; Tatsumi, Shinichi; Minami, Toshiaki

    2015-05-01

    The laryngeal tube (LT ; Smiths Medical, Minnesota, U. S. A) is an inflatable supraglottic device for emergency airway management such as during chest compression, the instability after insertion remains a problem. We investigated the effectiveness of three fixation methods of LT using a manikin and automated chest compressor. After 10-minute chest compression, LT without fixation was shifted by 0.4 ± 0.1 cm, which was greater than with Durapore tape (0.2 ± 0.1 cm), Multipore tape (0.2 ± 0.1 cm), or a neck tape (0.1 ± 0.1 cm). The shift of the position was smaller with neck tape fixation compared to Durapore or Multipore tape fixation. A fixation neck tape may be useful in stabilizing the inserted position of LT during cardiopulmonary resuscitation.

  5. Effect of Post Space Preparation on Apical Obturation Quality of Teeth Obturated with Different Techniques: A Micro-computed Tomographic Study.

    PubMed

    Küçükkaya Eren, Selen; Askerbeyli Örs, Sevinc; Yılmaz, Zeliha

    2017-07-01

    The purpose of this study was to evaluate the obturation quality of root canals filled with different techniques and to determine whether post space preparation had an effect on the quality of apical obturation using micro-computed tomographic (micro-CT) imaging. The root canals of 30 human mandibular premolar teeth were instrumented, and the specimens were divided into 3 groups according to the obturation technique used: cold lateral compaction (CLC), warm vertical compaction (WVC), or single-cone (SC) techniques. The specimens were stored at 37°C and 100% humidity for 1 week. Then, the coronal root filling material was removed in order to create a post space. Micro-CT scans were performed before and after post space preparation for the volumetric analysis of voids and filling materials. Data were analyzed using repeated-measures analysis of variance and Bonferroni tests. The CLC and SC groups showed a significantly greater percentage volume of voids than the WVC group (P < .05), whereas no significant difference was found between the CLC and SC groups before and after post space preparation (P > .05). The post space preparation caused a significant increase in the percentage volume of voids in the CLC and SC groups (P < .05). No significant difference was detected in the percentage volume of voids in the WVC group after post space preparation (P > .05). No root fillings were void free. The WVC group presented the best obturation quality. The post space preparation negatively influenced the apical integrity of the filling materials in the CLC and SC groups, whereas it had no significant effect in the WVC group. Copyright © 2017 American Association of Endodontists. Published by Elsevier Inc. All rights reserved.

  6. Vaginal health in contraceptive vaginal ring users - A review.

    PubMed

    Lete, Iñaki; Cuesta, María C; Marín, Juan M; Guerra, Sandra

    2013-08-01

    To provide an overview of the available data from clinical studies of vaginal conditions in women who use a vaginal ring as a contraceptive. A systematic review of the literature. Millions of women have already used the ethylene vinyl acetate vaginal ring that releases ethinylestradiol and etonogestrel for contraception. Because of its small size, more than four out of five women using the ring report that they do not feel it, even during sexual intercourse. No colposcopic or cytological changes have been observed in users, although approximately 10% have increased vaginal discharge. While in vitro studies have shown adhesion of Candida yeasts to the vaginal ring surface, clinical studies have not demonstrated a greater incidence of Candida infections compared to users of equivalent oral contraceptives. Some clinical studies suggest a lower incidence of bacterial vaginosis. No interaction exists between concomitant use of the vaginal ring and other drugs or products for vaginal use. The use of a contraceptive vaginal ring does not alter the vaginal ecosystem and therefore does not substantially affect vaginal health.

  7. Vaginal Microbiomes Associated With Aerobic Vaginitis and Bacterial Vaginosis.

    PubMed

    Kaambo, Evelyn; Africa, Charlene; Chambuso, Ramadhani; Passmore, Jo-Ann Shelley

    2018-01-01

    A healthy vaginal microbiota is considered to be significant for maintaining vaginal health and preventing infections. However, certain vaginal bacterial commensal species serve an important first line of defense of the body. Any disruption of this microbial barrier might result in a number of urogenital conditions including aerobic vaginitis (AV) and bacterial vaginosis (BV). The health of the vagina is closely associated with inhabitant microbiota. Furthermore, these microbes maintain a low vaginal pH, prevent the acquisition of pathogens, stimulate or moderate the local innate immune system, and further protect against complications during pregnancies. Therefore, this review will focus on vaginal microbial "health" in the lower reproductive tract of women and on the physiological characteristics that determine the well-being of reproductive health. In addition, we explore the distinct versus shared characteristics of BV and AV, which are commonly associated with increased risk for preterm delivery.

  8. Vaginal Microbiomes Associated With Aerobic Vaginitis and Bacterial Vaginosis

    PubMed Central

    Kaambo, Evelyn; Africa, Charlene; Chambuso, Ramadhani; Passmore, Jo-Ann Shelley

    2018-01-01

    A healthy vaginal microbiota is considered to be significant for maintaining vaginal health and preventing infections. However, certain vaginal bacterial commensal species serve an important first line of defense of the body. Any disruption of this microbial barrier might result in a number of urogenital conditions including aerobic vaginitis (AV) and bacterial vaginosis (BV). The health of the vagina is closely associated with inhabitant microbiota. Furthermore, these microbes maintain a low vaginal pH, prevent the acquisition of pathogens, stimulate or moderate the local innate immune system, and further protect against complications during pregnancies. Therefore, this review will focus on vaginal microbial “health” in the lower reproductive tract of women and on the physiological characteristics that determine the well-being of reproductive health. In addition, we explore the distinct versus shared characteristics of BV and AV, which are commonly associated with increased risk for preterm delivery. PMID:29632854

  9. Vaginal microbicides and teenagers.

    PubMed

    Rupp, Richard E; Rosenthal, Susan L

    2003-10-01

    Sexually active teens are at significant risk from sexually transmitted infections and girls and women bear the greatest burden of these infections. New methods, such as vaginal microbicides, would provide female controlled options. Microbicides are currently in development and thus it is timely to discuss the progress made and factors that may influence acceptability for teens. Microbicide development presents many challenges, and several different potential mechanisms of action are being explored. There is interest in these products from women and men, and specific preferences are being investigated. Adolescents, due to reproductive system immaturity, developing cognitive abilities and the psychosocial context of their relationships, present a special set of challenges in efforts to foster microbicide use. Vaginal microbicides are on the horizon. Further study into teen issues is required to develop successful strategies for marketing and encouraging adolescent use of microbicides.

  10. A quantitative and qualitative analysis of ultrasonic versus sonic endodontic systems on canal cleanliness and obturation.

    PubMed

    Kanter, Valerie; Weldon, Emily; Nair, Uma; Varella, Claudio; Kanter, Keith; Anusavice, Kenneth; Pileggi, Roberta

    2011-12-01

    The purpose of this study was to compare 2 irrigation techniques by evaluating canal cleanliness and obturation of lateral/accessory canals. Seventy-five extracted canines were instrumented to a size #40/0.06 taper. The EndoActivator (EA) was compared with an ultrasonic unit for final irrigation. Each unit was used for 1 minute each with 6.15% NaOCl and 17% EDTA. A control group received syringe irrigation. Thirty teeth were sectioned and evaluated for debris removal and open dentinal tubules at 3/5 mm from the apical foramen with a scanning electron microscope. Forty-five teeth were examined for obturation of lateral canals. The EA was significantly better in removing debris at all levels when compared with other treatment groups (P < .05) and resulted in obturation of significantly more numbers of lateral canals (P < .01.) The EA provided better obturation of lateral and accessory canals and resulted in less remaining debris. Copyright © 2011 Mosby, Inc. All rights reserved.

  11. Bacterial entombment by intratubular mineralization following orthograde mineral trioxide aggregate obturation: a scanning electron microscopy study

    PubMed Central

    Yoo, Jun Sang; Chang, Seok-Woo; Oh, So Ram; Perinpanayagam, Hiran; Lim, Sang-Min; Yoo, Yeon-Jee; Oh, Yeo-Rok; Woo, Sang-Bin; Han, Seung-Hyun; Zhu, Qiang; Kum, Kee-Yeon

    2014-01-01

    The time domain entombment of bacteria by intratubular mineralization following orthograde canal obturation with mineral trioxide aggregate (MTA) was studied by scanning electron microscopy (SEM). Single-rooted human premolars (n=60) were instrumented to an apical size #50/0.06 using ProFile and treated as follows: Group 1 (n=10) was filled with phosphate buffered saline (PBS); Group 2 (n=10) was incubated with Enterococcus faecalis for 3 weeks, and then filled with PBS; Group 3 (n=20) was obturated orthograde with a paste of OrthoMTA (BioMTA, Seoul, Korea) and PBS; and Group 4 (n=20) was incubated with E. faecalis for 3 weeks and then obturated with OrthoMTA–PBS paste. Following their treatments, the coronal openings were sealed with PBS-soaked cotton and intermediate restorative material (IRM), and the roots were then stored in PBS for 1, 2, 4, 8 or 16 weeks. After each incubation period, the roots were split and their dentin/MTA interfaces examined in both longitudinal and horizontal directions by SEM. There appeared to be an increase in intratubular mineralization over time in the OrthoMTA-filled roots (Groups 3 and 4). Furthermore, there was a gradual entombment of bacteria within the dentinal tubules in the E. faecalis inoculated MTA-filled roots (Group 4). Therefore, the orthograde obturation of root canals with OrthoMTA mixed with PBS may create a favorable environment for bacterial entombment by intratubular mineralization. PMID:25012869

  12. Use of a magnetic attachment to retain an obturator prosthesis for an osseous defect.

    PubMed

    Kawamoto, Shin-ichiro; Hamamura, Syunichi; Kawahara, Hideki; Nishi, Yasuhiro; Nagaoka, Eiichi

    2009-06-01

    Tooth loss accompanied by a massive defect of the alveolar bone can cause serious problems such as food deposit and esthetic impairment. This report describes procedures for the fabrication of an osseous defect obturator prosthesis connected to a fixed partial denture by a magnetic attachment along with the clinical outcome.

  13. Variation of distances from mid-urethra to the obturator foramen: an MRI study

    PubMed Central

    Doumouchtsis, Stergios K.; Berger, Mitchell B.; DeLancey, John O.

    2013-01-01

    Introduction and hypothesis To estimate distances from the mid-urethra to the obturator foramina and to explore correlations between pelvic dimensions and body height. Methods This is a secondary analysis of a parent case–control study on the mechanisms of stress urinary incontinence. We measured pelvic dimensions on magnetic resonance images of women with (cases, n=50) and without (controls, n=50) stress urinary incontinence. Results The mean distance from mid-urethra to the obturator membrane among cases is 31.8 mm (left) and 32.1 mm (right), with a range from 25.9 to 42.0 mm. There were no significant differences in these distances when comparing left with right, or cases with controls. Weak correlation was found between the urethra-to-obturator foramina distances and heights only in the case subjects. Conclusion There is high variability in the distance from mid-urethra to the obturator foramina. Height should not be used as a predictor of dimensions in the lesser pelvis. PMID:22543545

  14. Tape-recorded Lectures With Slide Synchronization

    ERIC Educational Resources Information Center

    Goodhue, D.

    1969-01-01

    Describes "Taped Explanation Slide Synchronization" programs used for individual study or group showing in college zoology. Discusses preparation of programs, class organization, equipment, and costs. (EB)

  15. Influence of root canal instrumentation and obturation techniques on intra-operative pain during endodontic therapy

    PubMed Central

    Martín-González, Jenifer; Echevarría-Pérez, Marta; Sánchez-Domínguez, Benito; Tarilonte-Delgado, Maria L.; Castellanos-Cosano, Lizett; López-Frías, Francisco J.

    2012-01-01

    Objective: To analyse the influence of root canal instrumentation and obturation techniques on intra-operative pain experienced by patients during endodontic therapy. Method and Materials: A descriptive cross-sectional study was carried out in Ponferrada and Sevilla, Spain, including 80 patients (46 men and 34 women), with ages ranged from 10 to 74 years, randomly recruited. Patient gender and age, affected tooth, pulpal diagnosis, periapical status, previous NSAID or antibiotic (AB) treatment, and root canal instrumentation and obturation techniques were recorded. After root canal treatment (RCT), patients completed a 10-cm visual analogue scale (VAS) that ranked the level of pain. Results were analysed statistically using the Chi-square and ANOVA tests and logistic regression analysis. Results: The mean pain level during root canal treatment was 2.9 ± 3.0 (median = 2) in a VAS between 0 and 10. Forty percent of patients experienced no pain. Gender, age, arch, previous NSAIDs or AB treatment and anaesthetic type did not influence significantly the pain level (p > 0.05). Pain during root canal treatment was significantly greater in molar teeth (OR = 10.1; 95% C.I. = 1.6 - 63.5; p = 0.013). Root canal instrumentation and obturation techniques did not affect significantly patient’s pain during root canal treatment (p > 0.05). Conclusion: Patients feel more pain when RCT is carried out on molar teeth. The root canal instrumentation and obturation techniques do not affect significantly the patients’ pain during RCT. Key words:Anaesthesia, endodontic pain, pulpitis, root canal instrumentation, root canal obturation, rotary files. PMID:22549694

  16. FGGE/ERBZ tape specification and shipping letter description

    NASA Technical Reports Server (NTRS)

    Han, D.; Lo, H.

    1983-01-01

    The FGGE/ERBZ tape contains 5 parameters which are extracted and reformatted from the Nimbus-7 ERB Zonal Means Tape. There are three types of files on a FGGE/ERBZ tape: a tape header file, and data files. Physical characteristics, gross format, and file specifications are given. A sample tape check/document printout (shipping letter) is included.

  17. Survey of Scientific-Technical Tape Services.

    ERIC Educational Resources Information Center

    Carroll, Kenneth D., Ed.

    The results of a survey of commercially available tape services which can provide libraries and information centers with data bases of scientific and technical literature are reported. During the past few years there has been an increasing number of tape services entering the information resources market. Each of these services makes available to…

  18. 21 CFR 886.1905 - Nystagmus tape.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES OPHTHALMIC DEVICES Diagnostic Devices § 886.1905 Nystagmus tape. (a) Identification. Nystagmus tape is a device that is a long, narrow strip of fabric or other flexible material on which a series of objects are...

  19. Multiple Generations on Video Tape Recorders.

    ERIC Educational Resources Information Center

    Wiens, Jacob H.

    Helical scan video tape recorders were tested for their dubbing characteristics in order to make selection data available to media personnel. The equipment, two recorders of each type tested, was submitted by the manufacturers. The test was designed to produce quality evaluations for three generations of a single tape, thereby encompassing all…

  20. Randomized trial of a comparison of the efficacy of TVT-O and single-incision tape TVT SECUR systems in the treatment of stress urinary incontinent women--2-year follow-up.

    PubMed

    Masata, Jaromir; Svabik, Kamil; Zvara, Karel; Drahoradova, Petra; El Haddad, Rachid; Hubka, Petr; Martan, Alois

    2012-10-01

    The aim of this study was to compare the efficacy of the use of tension-free vaginal tape obturator (TVT-O) and single-incision TVT SECUR, hammock and U approach (TVT-S, H and U), in the treatment of urodynamic stress urinary incontinence (SUI). This single-center randomized three-arm trial compared the objective and subjective efficacy and early failure rate of the TVT-O and TVT-S H and U approach by objective criteria (cough test) and subjective criteria using the International Consultation on Incontinence Questionnaire--Short Form (ICIQ-UI SF). The objective efficacy rate was defined as the number of patients with a negative cough stress test. Subjective cure was defined by no stress leakage of urine after surgery based on the evaluation of ICIQ-UI SH (when patients ticked "Never"/"Urine does not leak" in answer to question 6: When does urine leak?). Objective and subjective efficacy were evaluated using Last Failure Carried Forward analysis, i.e., final analysis also included patients with early failure. To describe outcome at different time points, the Last Observation Carried Forward method was also implemented. One hundred ninety-seven women with proven SUI were randomized into three groups--TVT-O (n = 68), TVT-S H (n = 64), and TVT-S U (n = 65). Each patient allocated to a treatment group received the planned surgery. There were no differences in each group in preoperative characteristics. Median follow-up after surgery was 2 years (SD, 0.8; range, 0.1 to 3.8 years). Of the subjects, 92.6% in the TVT-O group, 68.8% in the TVT-S H group, and 69.2% in the TVT-S U group had negative stress test (p < 0.001). Of the subjects, 85.3 % in the TVT-O group, 68.8% in the TVT-S H group, and 61.5% in the TVT-S U group were subjectively continent (p = 0.02). Our study demonstrated a significantly lower subjective and objective cure rate in the single-incision TVT group compared to the TVT-O group.

  1. Newly developed vaginal atrophy symptoms II and vaginal pH: a better correlation in vaginal atrophy?

    PubMed

    Tuntiviriyapun, P; Panyakhamlerd, K; Triratanachat, S; Chatsuwan, T; Chaikittisilpa, S; Jaisamrarn, U; Taechakraichana, N

    2015-04-01

    The primary objective of this study was to evaluate the correlation among symptoms, signs, and the number of lactobacilli in postmenopausal vaginal atrophy. The secondary objective was to develop a new parameter to improve the correlation. A cross-sectional descriptive study. Naturally postmenopausal women aged 45-70 years with at least one clinical symptom of vaginal atrophy of moderate to severe intensity were included in this study. All of the objective parameters (vaginal atrophy score, vaginal pH, the number of lactobacilli, vaginal maturation index, and vaginal maturation value) were evaluated and correlated with vaginal atrophy symptoms. A new parameter of vaginal atrophy, vaginal atrophy symptoms II, was developed and consists of the two most bothersome symptoms (vaginal dryness and dyspareunia). Vaginal atrophy symptoms II was analyzed for correlation with the objective parameters. A total of 132 naturally postmenopausal women were recruited for analysis. Vaginal pH was the only objective parameter found to have a weak correlation with vaginal atrophy symptoms (r = 0.273, p = 0.002). The newly developed vaginal atrophy symptoms II parameter showed moderate correlation with vaginal pH (r = 0.356, p < 0.001) and a weak correlation with the vaginal atrophy score (r = 0.230, p < 0.001). History of sexual intercourse within 3 months was associated with a better correlation between vaginal atrophy symptoms and the objective parameters. Vaginal pH was significantly correlated with vaginal atrophy symptoms. The newly developed vaginal atrophy symptoms II was associated with a better correlation. The vaginal atrophy symptoms II and vaginal pH may be better tools for clinical evaluation and future study of the vaginal ecosystem.

  2. Tape SCSI monitoring and encryption at CERN

    NASA Astrophysics Data System (ADS)

    Laskaridis, Stefanos; Bahyl, V.; Cano, E.; Leduc, J.; Murray, S.; Cancio, G.; Kruse, D.

    2017-10-01

    CERN currently manages the largest data archive in the HEP domain; over 180PB of custodial data is archived across 7 enterprise tape libraries containing more than 25,000 tapes and using over 100 tape drives. Archival storage at this scale requires a leading edge monitoring infrastructure that acquires live and lifelong metrics from the hardware in order to assess and proactively identify potential drive and media level issues. In addition, protecting the privacy of sensitive archival data is becoming increasingly important and with it the need for a scalable, compute-efficient and cost-effective solution for data encryption. In this paper, we first describe the implementation of acquiring tape medium and drive related metrics reported by the SCSI interface and its integration with our monitoring system. We then address the incorporation of tape drive real-time encryption with dedicated drive hardware into the CASTOR [1] hierarchical mass storage system.

  3. Comparative evaluation of three obturation techniques in primary incisors using digital intra-oral receptor and C.B.C.T-an in vitro study.

    PubMed

    Akhil, Jose E J; Prashant, Babaji; Shashibushan, K K

    2018-05-10

    Successful pulpectomy in primary teeth depends on quality of obturation. It can be evaluated using digital intra-oral receptor (D.I.O.R) and cone beam computed tomography (C.B.C.T). The purposes of this study were to compare 3 different obturation techniques such as lentulospiral, insulin syringe, and endodontic plugger in primary incisors and to evaluate its quality of obturation using D.I.O.R and C.B.C.T technique. Thirty-three extracted primary incisors were biomechanically prepared and obturated with zinc oxide eugenol cement by 3 different obturation techniques. The obturation was evaluated for length of obturation and voids using D.I.O.R and C.B.C.T methods. There was a statistically significant difference between all the groups in length of obturation (P = 0.02) in both D.I.O.R and C.B.C.T. Significant differences (P = 0.03) were present in number of voids among 3 obturation techniques in C.B.C.T. Statistically more voids were observed with D.I.O.R in lentulospiral (P = 0.04) group and in insulin syringe (P = 0.02) group. Acceptable result was obtained with lentulospiral in length of obturation compared to insulin syringe and endodontic plugger technique. Insulin syringe technique resulted in increased underfilling with least number of voids. More number of voids were seen in middle one-third and least number of voids were observed at apical one third of the root among all the 3 techniques of obturation. The study concluded that void identification is improved with D.I.O.R compared to C.B.C.T. Lentulospiral reported effective length of obturation, while insulin syringe with least number of voids. D.I.O.R (2-Dimensional) is efficient in detecting voids compared to C.B.C.T (3-Dimensional) in obturated primary teeth.

  4. Effect of 95% Ethanol as a Final Irrigant before Root Canal Obturation in Primary Teeth: An in vitro Study.

    PubMed

    Thiruvenkadam, G; Asokan, Sharath; John, Baby; Priya, Pr Geetha

    2016-01-01

    Successful obturation in the primary teeth demands complete dryness of the root canal system. The purpose of this study was to determine the effect of 95% ethanol as the final irrigant before root canal obturation in primary teeth. A total of 20 extracted primary mandibular canines were biomechanically prepared and pre-obturated volume of each tooth was assessed using spiral computed tomography (CT). The specimens were divided into two groups (n = 10): group 1, Metapex group; group 2, zinc oxide eugenol group. Each group was further divided randomly into two subgroups (n = 5): subgroup 1, canals were dried with 95% ethanol; subgroup 2, canals were blot dried with paper points with the last one appearing dry. All canals were obturated and the postobturated volume of each tooth was measured. The percentage of obturated volume (POV) was calculated using the formula: (postobturated volume/preobturated volume) × 100. The POV between the groups was statistically analyzed using Mann-Whitney test and Wilcoxon Signed rank test appropriately. Root canals that were dried with ethanol showed better obturation than using paper points alone and the difference was statistically significant in both group 1 (p < 0.001) and group 2 (p < 0.002). Drying of the root canal system with 95% ethanol can result in better obturation in the primary teeth. How to cite this article: Thiruvenkadam G, Asokan S, John B, Geetha Priya PR. Effect of 95% Ethanol as a Final Irrigant before Root Canal Obturation in Primary Teeth: An in vitro Study. Int J Clin Pediatr Dent 2016;9(1):21-24.

  5. Design and implementation of scalable tape archiver

    NASA Technical Reports Server (NTRS)

    Nemoto, Toshihiro; Kitsuregawa, Masaru; Takagi, Mikio

    1996-01-01

    In order to reduce costs, computer manufacturers try to use commodity parts as much as possible. Mainframes using proprietary processors are being replaced by high performance RISC microprocessor-based workstations, which are further being replaced by the commodity microprocessor used in personal computers. Highly reliable disks for mainframes are also being replaced by disk arrays, which are complexes of disk drives. In this paper we try to clarify the feasibility of a large scale tertiary storage system composed of 8-mm tape archivers utilizing robotics. In the near future, the 8-mm tape archiver will be widely used and become a commodity part, since recent rapid growth of multimedia applications requires much larger storage than disk drives can provide. We designed a scalable tape archiver which connects as many 8-mm tape archivers (element archivers) as possible. In the scalable archiver, robotics can exchange a cassette tape between two adjacent element archivers mechanically. Thus, we can build a large scalable archiver inexpensively. In addition, a sophisticated migration mechanism distributes frequently accessed tapes (hot tapes) evenly among all of the element archivers, which improves the throughput considerably. Even with the failures of some tape drives, the system dynamically redistributes hot tapes to the other element archivers which have live tape drives. Several kinds of specially tailored huge archivers are on the market, however, the 8-mm tape scalable archiver could replace them. To maintain high performance in spite of high access locality when a large number of archivers are attached to the scalable archiver, it is necessary to scatter frequently accessed cassettes among the element archivers and to use the tape drives efficiently. For this purpose, we introduce two cassette migration algorithms, foreground migration and background migration. Background migration transfers cassettes between element archivers to redistribute frequently accessed

  6. Heterogeneity of Vaginal Microbial Communities within Individuals▿ #

    PubMed Central

    Kim, Tae Kyung; Thomas, Susan M.; Ho, Mengfei; Sharma, Shobha; Reich, Claudia I.; Frank, Jeremy A.; Yeater, Kathleen M.; Biggs, Diana R.; Nakamura, Noriko; Stumpf, Rebecca; Leigh, Steven R.; Tapping, Richard I.; Blanke, Steven R.; Slauch, James M.; Gaskins, H. Rex; Weisbaum, Jon S.; Olsen, Gary J.; Hoyer, Lois L.; Wilson, Brenda A.

    2009-01-01

    Recent culture-independent studies have revealed that a healthy vaginal ecosystem harbors a surprisingly complex assemblage of microorganisms. However, the spatial distribution and composition of vaginal microbial populations have not been investigated using molecular methods. Here, we evaluated site-specific microbial composition within the vaginal ecosystem and examined the influence of sampling technique in detection of the vaginal microbiota. 16S rRNA gene clone libraries were prepared from samples obtained from different locations (cervix, fornix, outer vaginal canal) and by different methods (swabbing, scraping, lavaging) from the vaginal tracts of eight clinically healthy, asymptomatic women. The data reveal that the vaginal microbiota is not homogenous throughout the vaginal tract but differs significantly within an individual with regard to anatomical site and sampling method used. Thus, this study illuminates the complex structure of the vaginal ecosystem and calls for the consideration of microenvironments when sampling vaginal microbiota as a clinical predictor of vaginal health. PMID:19158255

  7. New technique to fabricate an immediate surgical obturator restoring the defect in original anatomical form.

    PubMed

    Patil, Pravinkumar G

    2011-08-01

    The presence of oral cancer can necessitate the surgical removal of all or part of the maxilla, leaving the patient with a defect compromising the oral cavity's integrity and function. The immediate postoperative restoration of esthetics, deglutition, and speech shortens recovery time in the hospital and expedites the patient's return to the community as a functioning member. This article describes a simple technique to fabricate an immediate surgical obturator by restoring the patient's original dentition and facial and palatal tissue form. An immediate obturator fabricated with this technique supports soft tissues after surgery and minimizes scar contracture and disfigurement and thus may have a positive effect on the patient's psychology. © 2011 by The American College of Prosthodontists.

  8. Influence of irrigation and obturation techniques on artificial lateral root canal filling capacity.

    PubMed

    Silva, Emmanuel J; Herrera, Daniel R; Souza-Júnior, Eduardo J; Teixeira, João M

    2013-01-01

    The aim of this study was to evaluate the influence of two different irrigation protocols on artificial lateral root canal filling capacity using different obturation techniques. Sixty single-root human teeth were used. Two artificial lateral canals were created in the apical third. Root canals were instrumented up to a 45 K-file to the working length. Before each file, root canals were irrigated either with 2 mL of 2.5% NaOCl or 2% chlorhexidine gel with further irrigation with saline solution and 3 mL of 17% EDTA. Specimens were randomly divided into three groups according to the obturation technique: (1) lateral compaction technique; (2) Tagger hybrid technique; and (3) thermoplasticized technique using BeeFill 2 in 1. All groups used AH Plus as the root canal sealer. The specimens were decalcified and cleared in methyl salicylate. The total length of lateral canals was observed under X30 magnification with a stereomicroscope and measured on the buccal and lingual root surfaces using Leica IM50 software. The data were submitted to ANOVA and Tukey test (p < 0.05). Among the obturation techniques, BeeFill 2 in 1 showed deeper penetration into all lateral canals than the lateral compaction or Tagger hybrid techniques (p < 0.05). The lateral compaction group showed the worst results (p < 0.05). Irrigants did not affect the outcome; there was no difference between NaOCl and chlorhexidine when the same obturation technique was used (p > 0.05). Regardless of the irrigant used during endodontic procedures, the thermoplasticized techniques showed higher penetration behavior for filling artificial lateral canals than the lateral compaction technique.

  9. [Rehabilitation by hollow obturator prosthesis immediately after total maxillectomy for malignant tumor].

    PubMed

    Li, Xiao-ye; Yan, Ai-hui; Hao, Shuai; Li, Wei; Jiang, Xue-jun; Lu, Li; Qin, Xing-jun; Yan, Hai-xin

    2011-05-01

    The feasibility and clinical effects of hollow obturator prosthesis for the repair of maxillofacial defect immediately after maxillectomy for cancer were assessed. Thirteen patients with T3-4aN0M0 maxillary neoplasm were treated by the prostheses immediately after maxillectomy. According to the 3D-CT reconstruction of nasal sinus, the 3D stereoscopic prototype was constructed before the surgery. Simulating surgery with Surgicare 5.0 software and then the prosthesis 3D stereoscopic model was shaped. The prosthesis was made quickly and precisely with methacrylate resins according to the model and the print mold before surgery, with supplementary tooth at the bottom of prosthesis. In the surgery, the prosthesis was installed instantly after maxillectomy. The patients were followed up at 1, 3 and 6 month after the surgery, respectively. The facial features and the pronunciation clarity were examined and the questionnaires were carried out in the patients, with comparation by paired t-test. The hollow obturator prosthesis would be replaced by permanent prosthesis made of methacrylate resins at 6 month after the surgery. The hollow obturator prostheses were installed accurately and maxillofacial defects were repaired immediately after maxillectomy in the 13 patients. Postoperative follow-up showed there were significant differences in eyeball sagging (t = 4.67, P < 0.05), mid-facial region collapse (t = 5.67, P < 0.05), and pronunciation clarity (t = 16.38, P < 0.05) between patients with and without prostheses. Questionnaires showed that all the patients were satisfied with the retention of prostheses, the improvement of appearance, the improvement of the symptom of water choking and speech definition. Six months after the surgery, the hollow obturator prostheses were replaced smoothly by permanent prostheses in 11 of the 13 patients. The precise and instant repair of maxillofacial defect by prosthesis after maxillectomy can improve survival quality of patient.

  10. Finite element analysis of maxillary bone stress caused by Aramany Class IV obturator prostheses.

    PubMed

    Miyashita, Elcio Ricardo; Mattos, Beatriz Silva Câmara; Noritomi, Pedro Yoshito; Navarro, Hamilton

    2012-05-01

    The retention of an Aramany Class IV removable partial dental prosthesis can be compromised by a lack of support. The biomechanics of this obturator prosthesis result in an unusual stress distribution on the residual maxillary bone. This study evaluated the biomechanics of an Aramany Class IV obturator prosthesis with finite element analysis and a digital 3-dimensional (3-D) model developed from a computed tomography scan; bone stress was evaluated according to the load placed on the prosthesis. A 3-D model of an Aramany Class IV maxillary resection and prosthesis was constructed. This model was used to develop a finite element mesh. A 120 N load was applied to the occlusal and incisal platforms corresponding to the prosthetic teeth. Qualitative analysis was based on the scale of maximum principal stress; values obtained through quantitative analysis were expressed in MPa. Under posterior load, tensile and compressive stresses were observed; the tensile stress was greater than the compressive stress, regardless of the bone region, and the greatest compressive stress was observed on the anterior palate near the midline. Under an anterior load, tensile stress was observed in all of the evaluated bone regions; the tensile stress was greater than the compressive stress, regardless of the bone region. The Aramany Class IV obturator prosthesis tended to rotate toward the surgical resection when subjected to posterior or anterior loads. The amount of tensile and compressive stress caused by the Aramany Class IV obturator prosthesis did not exceed the physiological limits of the maxillary bone tissue. (J Prosthet Dent 2012;107:336-342). Copyright © 2012 The Editorial Council of the Journal of Prosthetic Dentistry. Published by Mosby, Inc. All rights reserved.

  11. Kinesio Taping Fundamentals for the Equine Athlete.

    PubMed

    Molle, Sybille

    2016-04-01

    The Kinesio taping method was developed in Japan for use in humans in 1979. The use of complementary therapies is becoming common in equine athletes and the discovery of Kinesio taping potential brought it into the animal world. Kinesio taping can be used to treat a wide range of clinical conditions, from tendon injuries to neurologic disorders and from muscle contractures to postural insufficiencies. Its use in veterinary medicine is promising, but relies heavily on evidence-based clinical reports. Further scientific research is needed to fully understand the real effectiveness of application. Copyright © 2016 Elsevier Inc. All rights reserved.

  12. Episiotomy for vaginal birth

    PubMed Central

    Carroli, Guillermo; Mignini, Luciano

    2014-01-01

    Background Episiotomy is done to prevent severe perineal tears, but its routine use has been questioned. The relative effects of midline compared with midlateral episiotomy are unclear. Objectives The objective of this review was to assess the effects of restrictive use of episiotomy compared with routine episiotomy during vaginal birth. Search methods We searched the Cochrane Pregnancy and Childbirth Group’s Trials Register (March 2008). Selection criteria Randomized trials comparing restrictive use of episiotomy with routine use of episiotomy; restrictive use of mediolateral episiotomy versus routine mediolateral episiotomy; restrictive use of midline episiotomy versus routine midline episiotomy; and use of midline episiotomy versus mediolateral episiotomy. Data collection and analysis The two review authors independently assessed trial quality and extracted the data. Main results We included eight studies (5541 women). In the routine episiotomy group, 75.15% (2035/2708) of women had episiotomies, while the rate in the restrictive episiotomy group was 28.40% (776/2733). Compared with routine use, restrictive episiotomy resulted in less severe perineal trauma (relative risk (RR) 0.67, 95% confidence interval (CI) 0.49 to 0.91), less suturing (RR 0.71, 95% CI 0.61 to 0.81) and fewer healing complications (RR 0.69, 95% CI 0.56 to 0.85). Restrictive episiotomy was associated with more anterior perineal trauma (RR 1.84, 95% CI 1.61 to 2.10). There was no difference in severe vaginal/perineal trauma (RR 0.92, 95% CI 0.72 to 1.18); dyspareunia (RR 1.02, 95% CI 0.90 to 1.16); urinary incontinence (RR 0.98, 95% CI 0.79 to 1.20) or several pain measures. Results for restrictive versus routine mediolateral versus midline episiotomy were similar to the overall comparison. Authors’ conclusions Restrictive episiotomy policies appear to have a number of benefits compared to policies based on routine episiotomy. There is less posterior perineal trauma, less suturing and

  13. Transfer of obturator nerve for femoral nerve injury: an experiment study in rats.

    PubMed

    Meng, Depeng; Zhou, Jun; Lin, Yaofa; Xie, Zheng; Chen, Huihao; Yu, Ronghua; Lin, Haodong; Hou, Chunlin

    2018-07-01

    Quadriceps palsy is mainly caused by proximal lesions in the femoral nerve. The obturator nerve has been previously used to repair the femoral nerve, although only a few reports have described the procedure, and the outcomes have varied. In the present study, we aimed to confirm the feasibility and effectiveness of this treatment in a rodent model using the randomized control method. Sixty Sprague-Dawley rats were randomized into two groups: the experimental group, wherein rats underwent femoral neurectomy and obturator nerve transfer to the femoral nerve motor branch; and the control group, wherein rats underwent femoral neurectomy without nerve transfer. Functional outcomes were measured using the BBB score, muscle mass, and histological assessment. At 12 and 16 weeks postoperatively, the rats in the experimental group exhibited recovery to a stronger stretch force of the knee and higher BBB score, as compared to the control group (p < 0.05). The muscle mass and myofiber cross-sectional area of the quadriceps were heavier and larger than those in the control group (p < 0.05). A regenerated nerve with myelinated and unmyelinated fibers was observed in the experimental group. No significant differences were observed between groups at 8 weeks postoperatively (p > 0.05). Obturator nerve transfer for repairing femoral nerve injury was feasible and effective in a rat model, and can hence be considered as an option for the treatment of femoral nerve injury.

  14. Sabots, Obturator and Gas-In-Launch Tube Techniques for Heat Flux Models in Ballistic Ranges

    NASA Technical Reports Server (NTRS)

    Bogdanoff, David W.; Wilder, Michael C.

    2013-01-01

    For thermal protection system (heat shield) design for space vehicle entry into earth and other planetary atmospheres, it is essential to know the augmentation of the heat flux due to vehicle surface roughness. At the NASA Ames Hypervelocity Free Flight Aerodynamic Facility (HFFAF) ballistic range, a campaign of heat flux studies on rough models, using infrared camera techniques, has been initiated. Several phenomena can interfere with obtaining good heat flux data when using this measuring technique. These include leakage of the hot drive gas in the gun barrel through joints in the sabot (model carrier) to create spurious thermal imprints on the model forebody, deposition of sabot material on the model forebody, thereby changing the thermal properties of the model surface and unknown in-barrel heating of the model. This report presents developments in launch techniques to greatly reduce or eliminate these problems. The techniques include the use of obturator cups behind the launch package, enclosed versus open front sabot designs and the use of hydrogen gas in the launch tube. Attention also had to be paid to the problem of the obturator drafting behind the model and impacting the model. Of the techniques presented, the obturator cups and hydrogen in the launch tube were successful when properly implemented

  15. Tape Cassette Bacteria Detection System

    NASA Technical Reports Server (NTRS)

    1973-01-01

    The design, fabrication, and testing of an automatic bacteria detection system with a zero-g capability and based on the filter-capsule approach is described. This system is intended for monitoring the sterility of regenerated water in a spacecraft. The principle of detection is based on measuring the increase in chemiluminescence produced by the action of bacterial porphyrins (i.e., catalase, cytochromes, etc.) on a luminol-hydrogen peroxide mixture. Since viable as well as nonviable organisms initiate this luminescence, viable organisms are detected by comparing the signal of an incubated water sample with an unincubated control. Higher signals for the former indicate the presence of viable organisms. System features include disposable sealed sterile capsules, each containing a filter membrane, for processing discrete water samples and a tape transport for moving these capsules through a processing sequence which involves sample concentration, nutrient addition, incubation, a 4 Molar Urea wash and reaction with luminol-hydrogen peroxide in front of a photomultiplier tube. Liquids are introduced by means of a syringe needle which pierces a rubber septum contained in the wall of the capsule. Detection thresholds obtained with this unit towards E. coli and S. marcescens assuming a 400 ml water sample are indicated.

  16. Effects of sociodemographic, treatment variables, and medical characteristics on quality of life of patients with maxillectomy restored with obturator prostheses.

    PubMed

    Artopoulou, Ioli Ioanna; Karademas, Evangelos C; Papadogeorgakis, Nikolaos; Papathanasiou, Ioannis; Polyzois, Gregory

    2017-12-01

    Restoration of maxillary defects resulting from tumor ablative surgery presents a difficult challenge, with both functional and esthetic issues. Whether rehabilitation with an obturator prosthesis could significantly contribute to improved quality of life in patients with maxillary resection has been scarcely studied, with relatively small study samples. The purpose of this survey study was to assess the overall functioning of the obturator prosthesis and the effect of specific sociodemographic, medical, and treatment variables on obturator functioning and quality of life in patients with maxillectomy. Global quality of life (QOL) and satisfaction with the obturator prosthesis of 57 patients who underwent maxillectomy and prosthetic rehabilitation at the National and Kapodistrian University of Athens were assessed using 3 questionnaires: European Organization for Research and Treatment of Cancer (EORTC) Quality of Life Questionnaire C30 (QLQ-C30), the EORTC QLQ-HN35, and the obturator functioning scale. The data were analyzed using the Kruskal-Wallis 1-way ANOVA on ranks, hierarchical multiple regression analysis, and the Spearman rank order correlation (α=.05). Satisfactory functioning of the obturator prosthesis was the most significant predictor of improved QOL (P<.05). QOL was significantly related to additional treatments (P<.05), the size of the primary tumor (P<.05), and the size of the maxillectomy defect (P<.05). The most significant predictors of good obturator functioning were additional treatments (P<.01), age at the time of surgery (P<.05), presence of mandibular teeth (P<.05), and previous maxillary removable prosthetic experience (P<.05). Obturator functioning scale appearance and insertion subscales (r=0.47, P<.01), followed by speech (r=0.42, P<.01), were significantly related to better QOL. A well-functioning obturator prosthesis was the most significant determinant for improved QOL in patients with maxillary resection. Age at the time of surgery

  17. Vaginal oxytetracycline concentrations.

    PubMed Central

    Thin, R N; Al Rawi, Z H; Simmons, P D; Treharne, J; Tabaqchali, S

    1979-01-01

    Although tetracycline preparations are widely used in departments of genitourinary medicine, or sexually transmitted diseases clinics, little is known of the concentrations of these preparations in genital secretions. For this reason a microbiological method was used for estimating oxytetracycline concentrations in vaginal secretions. These concentrations varied from 0.6 to 6.5 microgram/ml in 19 women who had had sexual contact with a man with non-specific urethritis and who were taking oxytetracycline dihydrate 250 mg four times daily. They were well in excess of the minimum inhibitory concentration of oxytetracycline (0.2 microgram/ml) for the strains of Chlamydia trachomatis isolated from the patients with positive culture results. Thus, oxytetracycline 250 mg four times daily appears to be a satisfactory regimen for the treatment of chlamydial genital infection in women. PMID:509190

  18. Laboratory diagnosis of vaginal infections.

    PubMed

    Metzger, G D

    1998-01-01

    Vaginal discomfort and/or odor are a common complaint in primary care visits by female patients. This is especially true among sexually active women of childbearing age. Because treatment varies depending upon which syndrome is present, effective treatment depends upon accurate diagnosis. The microscopic exams for diagnosing vaginal complaints are most frequently done in primary care sites. Because of this, few clinical laboratory scientists (CLSs) have the opportunity to become familiar with microscopy on this specimen type. In addition, literature on the subject is only gradually becoming available. This paper will attempt to briefly review the clinical and microscopic features of the common syndromes associated with vaginal discomfort.

  19. Comparative evaluation of endodontic pressure syringe, insulin syringe, jiffy tube, and local anesthetic syringe in obturation of primary teeth: An in vitro study.

    PubMed

    Hiremath, Mallayya C; Srivastava, Pooja

    2016-01-01

    The purpose of this in vitro study was to compare four methods of root canal obturation in primary teeth using conventional radiography. A total of 96 root canals of primary molars were prepared and obturated with zinc oxide eugenol. Obturation methods compared were endodontic pressure syringe, insulin syringe, jiffy tube, and local anesthetic syringe. The root canal obturations were evaluated by conventional radiography for the length of obturation and presence of voids. The obtained data were analyzed using Chi-square test. The results showed significant differences between the four groups for the length of obturation (P < 0.05). The endodontic pressure syringe showed the best results (98.5% optimal fillings) and jiffy tube showed the poor results (37.5% optimal fillings) for the length of obturation. The insulin syringe (79.2% optimal fillings) and local anesthetic syringe (66.7% optimal fillings) showed acceptable results for the length of root canal obturation. However, minor voids were present in all the four techniques used. Endodontic pressure syringe produced the best results in terms of length of obturation and controlling paste extrusion from the apical foramen. However, insulin syringe and local anesthetic syringe can be used as effective alternative methods.

  20. Light-Curing Adhesive Repair Tapes

    NASA Technical Reports Server (NTRS)

    Allred, Ronald; Haight, Andrea Hoyt

    2009-01-01

    Adhesive tapes, the adhesive resins of which can be cured (and thereby rigidized) by exposure to ultraviolet and/or visible light, are being developed as repair patch materials. The tapes, including their resin components, consist entirely of solid, low-outgassing, nonhazardous or minimally hazardous materials. They can be used in air or in vacuum and can be cured rapidly, even at temperatures as low as -20 C. Although these tapes were originally intended for use in repairing structures in outer space, they can also be used on Earth for quickly repairing a wide variety of structures. They can be expected to be especially useful in situations in which it is necessary to rigidize tapes after wrapping them around or pressing them onto the parts to be repaired.

  1. Structural modeling of HTS tapes and cables

    NASA Astrophysics Data System (ADS)

    Allen, N. C.; Chiesa, L.; Takayasu, M.

    2016-12-01

    Structural finite element analysis (FEA) has been used as an insightful tool to investigate the electromechanical behavior of HTS REBCO tapes and twisted stacked-tape cables under tension, torsion, bending and combined loads. A novel technique was developed for modeling the layered composite structure of the 2G tapes with structural solid-shell elements in ANSYS®. The FEA models produced detailed strain information for the REBCO superconducting layer which was then paired with an analytical model to predict the critical current performance of the 2G HTS tapes under various loads. Two commercially available HTS tapes (SuperPower and SuNAM) under tension, torsion and combined tension-torsion were first analyzed with FEA and compared with available experimental results at 77 K. A sharp critical current degradation was experienced at the yield strength of the tapes under tension and below a 100 mm twist-pitch under torsion. Combined tension-torsion loads had a more gradual degradation of critical current for twist-pitches of 115 mm or shorter but had a negligible difference compared to pure tension for longer twist-pitches. Using the structural solid-shell technique for modeling 2G tapes in ANSYS®, an FEA methodology for simulating full scale three-dimensional HTS stacked-tape cables under pure bending was created. A model of a Twisted-Stacked Tape Cable (TSTC), a configuration first proposed at MIT, was initially developed and then adapted to the slotted-core HTS Cable-In-Conduit Conductor produced by the ENEA laboratory in Italy. The numerical axial strain of the HTS REBCO tapes within the cables as calculated by FEA were found to agree with an analytical model for two cases: perfect-slip (frictionless) and no-slip (bonded). The ENEA CICC model was also compared with recent experimental critical current data at 77 K and was found to match best using a low friction coefficient of 0.02 indicating that the tapes within the cable freely slide with respect to each other

  2. Ankle taping: support given by different materials.

    PubMed Central

    Capasso, G; Maffulli, N; Testa, V

    1989-01-01

    Three different adhesive and two non-adhesive tapes were used by three operators to assess the compressive action exerted on the ankle at the moment of strapping, during different phases of gait, and after some days of treatment in ten volunteers. Only the adhesive tapes were still able to prevent swelling after five days. They should be used if a prolonged compressive action is required. Images Figure 1 PMID:2517042

  3. Aligned Carbon Nanotube Tape for Sensor Applications

    NASA Technical Reports Server (NTRS)

    Tucker, Dennis S.

    2013-01-01

    For this effort, will concentrate on three applications: Vibration Gyroscope utilizes piezoelectric properties of the tape and Coriolis effect Accelerometer utilizes the piezoresistive property Strain Gauge utilizes piezoresistive property Accelerometer and Strain Gauge can also utilize piezoelectric effect Test piezoelectric properties using facilities at the Microfabrication Laboratory (AMRDEC) . Enhance piezoelectric effect using polyvinylidine fluoride and P(VDF ]TrFE) which is readily polarizable .Spray matrix solution while winding fiber; Sandwich of CNT tape and PVDF film (DOE .Two Level) . Construct and test prototype vibration gyroscope . Construct and test prototype accelerometer using cantilever design . Test strain sensitivity of CNT tape against industrial strain gauge . Embed CNT tape in composite samples as well as on surface and test to failure (4 ]point bend) A piezoelectric device exhibits an electrical response from a mechanical applied stress. . A piezoelectric device has both capacitance and resistance properties in which by applying an electric field from a waveform will exert a mechanical stress that can be monitored for a response. . The typical waveform applied is a sinusoidal waveform of a defined voltage for a defined period. The defined voltage is driven from 0 volts to the positive defined volts then back to 0 and driven to negative defined volts then back to 0. . Example. Vmax set to 10V and period set to 10 ms. . Voltage will start at zero, go to 10 volts, return to zero, go to ]10 volts and return to zero during 10 ms. . Applying this electrical field to a DUT, the capacitance response and resistance response can be observed. CNT tape is easier to manufacture and cheaper than micromachining silicon or other ceramic piezoelectric used in gyroscopes and accelerometers CNT tape properties can be modified during manufacture for specific application CNT tape has enhanced mechanical and thermal properties in addition to unique electrical

  4. Superconducting properties of multilayered Ag/Bi(Pb)-2223 tapes prepared using pretextured monolayered tapes

    NASA Astrophysics Data System (ADS)

    Syamaprasad, U.; Sarma, M. S.; Guruswamy, P.; Pillai, S. G. K.; Warrier, K. G. K.; Damodaran, A. D.

    1997-02-01

    Multilayered Ag/Bi(Pb)-2223 tapes with high critical current densities 0953-2048/10/2/005/img1 have been fabricated using partially heat treated, textured monolayered tapes. Cut sections of the monolayered tapes have been stacked one over the other and folded together using high-purity silver foil and further rolled and heat treated to obtain multilayered tapes of different thickness with an HTS layer thickness varying from 9 to 0953-2048/10/2/005/img2. A comparison of the superconducting properties of the multilayered tapes with those of monolayered tapes prepared under identical heat treatment conditions shows that the 0953-2048/10/2/005/img3 ratio at 77 K is as high as 0.57. The ratio is found to decrease with a decrease in the HTS core thickness of the multilayered tapes. XRD studies of `banana peeled' samples show that the monolayered tapes at the folding stage acquire a good degree of texturing. The relatively high value of the 0953-2048/10/2/005/img3 ratio obtained in the present case compared with those reported by the existing techniques is attributed to the use of pretextured monolayered tapes.

  5. Pollen tube access to the ovule is mediated by glycoprotein secretion on the obturator of apple (Malus × domestica, Borkh)

    PubMed Central

    Herrero, Maria

    2017-01-01

    Background and Aims Within the ovary, the obturator bridges the pathway of the pollen tube from the style to the ovule. Despite its widespread presence among flowering plants, its function has only been studied in a handful of species, and the molecules involved in pollen tube–obturator cross-talk have not been explored hitherto. This work evaluates the involvement of glucans and glycoproteins on pollen tube growth in the obturator of apple flowers (Malus × domestica). Methods Pollen tube kinetics were sequentially examined in the pistil and related to changes occurring on the obturator using histochemistry and inmunocytochemistry. To discriminate between changes in the obturator induced by pollen tubes from those developmentally regulated, both pollinated and unpollinated pistils were examined. Key Results Pollen tube growth rates were slow in the stigma, faster in the style and slow again in the ovary. The arrival of pollen tubes at the obturator was concomitant with the secretion of proteins, saccharides and glycoprotein epitopes belonging to extensins and arabinogalactan proteins (AGPs). While some of these secretions – extensins and AGPs labelled by JIM13 – were developmentally regulated, others – AGPs labelled by JIM8 – were elicited by the presence of pollen tubes. Following pollen tube passage, all these glycoproteins were depleted. Conclusions The results show a timely secretion of glycoproteins on the obturator surface concomitant with pollen tube arrival at this structure. The fact that their secretion is depleted following pollen tube passage strongly suggests their role in regulating pollen tube access to the ovule. Remarkably, both the regulation of the secretion of the different glycoproteins, as well as their association with the performance of pollen tubes exhibit similarities with those observed in the stigma, in line with their common developmental origin. PMID:28137704

  6. Pollen tube access to the ovule is mediated by glycoprotein secretion on the obturator of apple (Malus × domestica, Borkh).

    PubMed

    Losada, Juan M; Herrero, Maria

    2017-04-01

    Within the ovary, the obturator bridges the pathway of the pollen tube from the style to the ovule. Despite its widespread presence among flowering plants, its function has only been studied in a handful of species, and the molecules involved in pollen tube-obturator cross-talk have not been explored hitherto. This work evaluates the involvement of glucans and glycoproteins on pollen tube growth in the obturator of apple flowers ( Malus × domestica) . Pollen tube kinetics were sequentially examined in the pistil and related to changes occurring on the obturator using histochemistry and inmunocytochemistry. To discriminate between changes in the obturator induced by pollen tubes from those developmentally regulated, both pollinated and unpollinated pistils were examined. Pollen tube growth rates were slow in the stigma, faster in the style and slow again in the ovary. The arrival of pollen tubes at the obturator was concomitant with the secretion of proteins, saccharides and glycoprotein epitopes belonging to extensins and arabinogalactan proteins (AGPs). While some of these secretions - extensins and AGPs labelled by JIM13 - were developmentally regulated, others - AGPs labelled by JIM8 - were elicited by the presence of pollen tubes. Following pollen tube passage, all these glycoproteins were depleted. The results show a timely secretion of glycoproteins on the obturator surface concomitant with pollen tube arrival at this structure. The fact that their secretion is depleted following pollen tube passage strongly suggests their role in regulating pollen tube access to the ovule. Remarkably, both the regulation of the secretion of the different glycoproteins, as well as their association with the performance of pollen tubes exhibit similarities with those observed in the stigma, in line with their common developmental origin. © The Author 2017. Published by Oxford University Press on behalf of the Annals of Botany Company. All rights reserved. For Permissions

  7. User's guide and tape specification for ERB 7 DELMAT

    NASA Technical Reports Server (NTRS)

    Ardanuy, P.; Penn, L.

    1985-01-01

    Guidance is provided to the DELMAT user in the areas of purpose, use and limitations of DELMAT tapes and software. The DELMAT tape specifications is also provided. The ERB-7, ERB MAT and tape characteristics applicable to the DELMAT tapes are also summarized.

  8. Chemical News Via Audio Tapes: Chemical Industry News

    ERIC Educational Resources Information Center

    Hanford, W. E.; And Others

    1972-01-01

    Tape coverage of internal R&D news now has a broader scope with improved features. A new tape series covering external news of broad interest has been initiated. The use of tape in a Continuing Education Program is discussed as the future plans for expanding the audio tape program. (1 reference) (Author)

  9. Educational Uses of Cartridge Tapes. Dissemination Document No. 11.

    ERIC Educational Resources Information Center

    Levine, S. Joseph

    Tape cartridges for use by special education teachers are analyzed according to design, effective use, and availability. Basic operating principles of cassette and continuous loop tape cartridges are described and illustrated. Advantages of tape cartridges are indicated, such as the following: the position is saved on tape during student timeouts,…

  10. Vaginal bleeding in early pregnancy

    MedlinePlus

    ... Network. Also reviewed by David Zieve, MD, MHA, Medical Director, Brenda Conaway, Editorial Director, and the A.D.A.M. Editorial team. Related MedlinePlus Health Topics Health Problems in Pregnancy Vaginal Bleeding Browse the Encyclopedia A. ...

  11. Vaginal eroticism: a replication study.

    PubMed

    Alzate, H

    1985-12-01

    Vaginal eroticism was investigated in a group of 27 coitally experienced volunteers by means of systematic digital stimulation of both vaginal walls. Erogenous zones were found in all subjects, mainly located on the upper anterior wall and the lower posterior one. An orgasmic response was elicited by stimulation of these zones in 89% of the subjects. This study supports previous findings regarding vaginal eroticism. It does not support the existence of the discrete anatomical structure called the Grafenberg spot. It supports the contention that there are two distinct types of female orgasm, vaginally evoked and clitorally evoked. It also supports the finding that some women expel a fluid through the urethra at the time of orgasm. In this particular case the fluid was chemically indistinguishable from urine.

  12. Treatment Option Overview (Vaginal Cancer)

    MedlinePlus

    ... stage of the cancer being treated. External and internal radiation therapy are used to treat vaginal cancer, and may also be used as palliative therapy to relieve symptoms and improve quality of life . Chemotherapy Chemotherapy is a cancer treatment ...

  13. Drugs Approved for Vaginal Cancer

    Cancer.gov

    This page lists cancer drugs approved by the Food and Drug Administration (FDA) to prevent vaginal cancer. The list includes generic names and brand names. The drug names link to NCI’s Cancer Drug Information summaries.

  14. Desquamative inflammatory vaginitis. A review.

    PubMed Central

    Oates, J K; Rowen, D

    1990-01-01

    Desquamative inflammatory vaginitis is an uncommon cause of an intractable vaginitis often accompanied by serious dyspareunia, which can occur at any stage of reproductive life and after the menopause. The cytological changes are identical with those seen in atrophic vaginitis yet the disorder often occurs in the presence of apparently normal ovarian function. Vaginal synechiae and stenosis develop in an appreciable number of patients. Treatment is unsatisfactory though there is some response to either local or systemic steroid therapy. The literature is reviewed and the association of some cases with lichen planus of the mouth and genitals discussed. Its causation and natural history remain largely unknown and there is as yet, insufficient evidence to regard it as a single entity. It is likely that the incidence of the disorder is underestimated. PMID:2202657

  15. FGGE/ERBM tape specification and shipping letter description

    NASA Technical Reports Server (NTRS)

    Han, D.; Lo, H.

    1983-01-01

    The Nimbus-7 FGGE/ERBM tape contains 27 ERB parameters which are extracted and reformatted from the Nimbus-7 ERB-MATRIX tape. There are four types of files on a FGGE/ERBM tape: a test file; tape-header file which describes the data set characteristics and the contents of the tape; a grid-descriptor file which contains the information of the ERB scanning channel target number and their associated latitude limits and longitude intervals; and one or more data files. A single end-of-file (EOF) tape mark is written after each file, and two EOF marks are written after the last data file on the tape.

  16. Vaginal rhinosporidiosis: a case report.

    PubMed

    Jahan, S; Haque, M A; Nessa, F; Begum, A; Hasan, A H; Sen, S; Huq, M H

    2014-07-01

    The female genital tract is an extremely rare site for Rhinosporidiosis. Here we described a 13 year old girl who presented with a slow growing polypoid fleshy mass in the posterior vaginal wall near the orifice for 6 months with scanty bleeding from the mass. The girl was admitted to hospital with profuse watery vaginal discharge. Excision of the mass was followed by histopathological examination which confirmed the diagnosis Rhinosporidiosis.

  17. Recurrent vaginal discharge in children.

    PubMed

    McGreal, Sharon; Wood, Paul

    2013-08-01

    Childhood vaginal discharge remains a frequent reason for referral from primary to secondary care. The Pediatric and Adolescent Gynecology (PAG) service at Kettering General Hospital was established in 1993 and provides a specialized service that meets the needs of children with gynaecological conditions. To investigate recurrent vaginal discharge noting symptomatology, defining pathogens, common and rarer causes, exploring management regimes, and any changes in practice over time. Retrospective review spanning 15 years identifying prepubertal children attending the outpatient PAG clinic with recurrent vaginal discharge. We reviewed the medical notes individually. 110 patients were identified; 85% were referred from primary care. The age distribution was bimodal at four and eight years. Thirty-five percent of our patients were discharged after the initial consultation. The commonest cause of discharge was vulvovaginitis (82%). Other important causes included suspected sexual abuse (5%), foreign body (3%), labial adhesions (3%), vaginal agenesis (2%). 35% of patients were admitted for vaginoscopy. Vaginal discharge is the most common gynecological symptom in prepubertal girls and can cause repeated clinical episodes. Vulvovaginitis is the most common cause and often responds to simple hygiene measures. Awareness of the less common causes of vaginal discharge is essential. Copyright © 2013 North American Society for Pediatric and Adolescent Gynecology. Published by Elsevier Inc. All rights reserved.

  18. Effect of Tape Burnishing and Drive Use on Head Wear in Rotary Tape Drives

    NASA Astrophysics Data System (ADS)

    Bhushan, Bharat; Anderson, Reid M.; Koinkar, Vilas N.

    Three types of 12.7-mm wide metal particle tapes were studied. One of the tapes was calendered, whereas the other two tapes were additionally burnished one or two times using a proprietary process. Each type of tape was studied after 100 passes in the BetaCam SP drive and also in the virgin (0 pass) state. It was reported that in the case of the unburnished tape, head wear was high in the first pass and decreased during use. However, head wear for the double burnished tape was low for the first pass and increased during use. Whereas in the single burnished tape, head wear was low in the first pass and remained low. The objective of this study is to understand the mechanisms for loss and growth of head wear by correlating the surface characteristics of the tapes to head wear rate and to determine the changes in the surface characteristics occurring from 0 to 100 passes in the drive. It was found that summit density, mean and rms summit height, and mean and rms summit curvature correlate well to the head wear data. During manufacture and use in the drive, as the summit density, mean and rms summit height, and mean and rms summit curvature decrease, the head wear rate decreases. The mechanism for head wear is the initial ploughing of dense, sharp and high tape asperities into the surface of the head material resulting in a high head wear rate and a high coefficient of friction. Double burnishing during manufacturing removes high asperities, thus making the tape very smooth and possibly results in high adhesion and head wear growth with use. Chemical changes of the tape surface during double burnishing (not part of this study) also may be responsible for head wear growth during use.

  19. Methods and systems for fabricating high quality superconducting tapes

    SciTech Connect

    Majkic, Goran; Selvamanickam, Venkat

    An MOCVD system fabricates high quality superconductor tapes with variable thicknesses. The MOCVD system can include a gas flow chamber between two parallel channels in a housing. A substrate tape is heated and then passed through the MOCVD housing such that the gas flow is perpendicular to the tape's surface. Precursors are injected into the gas flow for deposition on the substrate tape. In this way, superconductor tapes can be fabricated with variable thicknesses, uniform precursor deposition, and high critical current densities.

  20. Combined ultrasound and fluoroscopic guidance for radiofrequency ablation of the obturator nerve for intractable cancer-associated hip pain.

    PubMed

    Stone, Jonathan; Matchett, Gerald

    2014-01-01

    Management of pain from skeletal metastases is notoriously difficult. Case reports and case series have described radiofrequency ablation of the obturator nerve branches to the femoral head for treatment of intractable hip pain. Ablation of the obturator branches to the femoral head is technically difficult because of bony and vascular anatomy, including close proximity of the femoral vessels. Here we present the case of a 79-year-old woman with intractable right hip pain and inability to ambulate secondary to metastatic non-small cell lung cancer in the femoral head and acetabulum, treated with thermal radiofrequency ablation of the obturator and femoral nerve branches to the femoral head. Ablation of the obturator nerve was done via anterior placement of the radiofrequency needle under combined ultrasound and fluoroscopic guidance, passing the radiofrequency needle between the femoral artery and femoral vein. Real-time ultrasound guidance was used to avoid vascular puncture. Thermal radiofrequency ablation resulted in sustained pain relief, and resumption in the ability of the patient to ambulate. From this case we suggest that an anterior approach to the obturator nerve branches to the femoral head may be technically feasible using combined ultrasound and fluoroscopic guidance to avoid vascular puncture.

  1. Clinical and radiographic evaluation of zinc oxide with aloe vera as an obturating material in pulpectomy: an in vivo study.

    PubMed

    Khairwa, Abhishek; Bhat, Manohar; Sharma, Rajesh; Satish, V; Maganur, Prabhadevi; Goyal, Anil Kumar

    2014-01-01

    Pulp therapy for pulpally involved primary teeth continues to be a challenge to clinicians. One of the major areas of continued research is in the area of finding obturating materials to suit the specific properties of these teeth. Zinc oxide eugenol is used frequently in pulpectomy for the obturation of the primary teeth. To evaluate clinically and radiographically a mixture of zinc oxide eugenol and aloe vera as an obturating material. A total of 50 children, aged between 4 and 9 years, who were screened for unilateral or bilateral carious deciduous molars were studied. Out of these, 15 children were randomly selected for endodontic treatment. Obturation was done with a mixture of zinc oxide powder and aloe vera gel. Clinical and radiographic evaluation was done after 7 days, 1 month, 3 months, 6 months, and 9 months. The data were statistically analyzed. Endodontic treatment using a mixture of zinc oxide powder and aloe vera gel in primary teeth has shown good clinical and radiographic success. A detailed observational study with longer follow-up will highlight the benefits of aloe vera in primary teeth as an obturating medium.

  2. Strategy for robot motion and path planning in robot taping

    NASA Astrophysics Data System (ADS)

    Yuan, Qilong; Chen, I.-Ming; Lembono, Teguh Santoso; Landén, Simon Nelson; Malmgren, Victor

    2016-06-01

    Covering objects with masking tapes is a common process for surface protection in processes like spray painting, plasma spraying, shot peening, etc. Manual taping is tedious and takes a lot of effort of the workers. The taping process is a special process which requires correct surface covering strategy and proper attachment of the masking tape for an efficient surface protection. We have introduced an automatic robot taping system consisting of a robot manipulator, a rotating platform, a 3D scanner and specially designed taping end-effectors. This paper mainly talks about the surface covering strategies for different classes of geometries. The methods and corresponding taping tools are introduced for taping of following classes of surfaces: Cylindrical/extended surfaces, freeform surfaces with no grooves, surfaces with grooves, and rotational symmetrical surfaces. A collision avoidance algorithm is introduced for the robot taping manipulation. With further improvements on segmenting surfaces of taping parts and tape cutting mechanisms, such taping solution with the taping tool and the taping methodology can be combined as a very useful and practical taping package to assist humans in this tedious and time costly work.

  3. [Operative vaginal deliveries training].

    PubMed

    Dupuis, O

    2008-12-01

    The appropriate use of forceps, vacuums or spatulas facilitates the rapid delivery of foetuses faced with life-threatening situations. It also makes possible the relief of certain cases of prolonged second-stage labor. In France, operative vaginal delivery (OVD) accounts for approximately 10% of all births. OVD training aims to optimize maternal, as well as neonatal safety. It should enable trainees to indicate or contraindicate an OVD safely, as well as to choose the appropriate instrument, use it correctly, and master quality control principles. Traditional OVD training is confronted with both spatial and time-related limitations. Spatial constraints involve both the teacher and trainee who only have limited visual access to the pelvic canal, and the head of the foetus; the time constraint occurs whenever the OVD occurs in an emergency setting. These limitations have been further aggravated by new constraints: decreasing time dedicated to training (European safety rules prohibit work the day after night duty), increasing litigation, and constraints imposed by society. Training by means of simulation removes such limitations making it possible to both avoid exposing pregnant women to the hazards of traditional training, and adapt the training to the skills of each trainee. OVD training should include forceps, vacuums and the use of spatulas. The OVD skills of obstetricians should be audited regularly on both a personal and a confidential level. Such audits could be based on a method using a simulator. Prospective studies comparing traditional and simulation-based training should be encouraged.

  4. Definition of a type of abnormal vaginal flora that is distinct from bacterial vaginosis: aerobic vaginitis.

    PubMed

    Donders, Gilbert G G; Vereecken, Annie; Bosmans, Eugene; Dekeersmaecker, Alfons; Salembier, Geert; Spitz, Bernard

    2002-01-01

    To define an entity of abnormal vaginal flora: aerobic vaginitis. Observational study. University Hospital Gasthuisberg, Leuven, Belgium. 631 women attending for routine prenatal care or attending vaginitis clinic. Samples were taken for fresh wet mount microscopy of vaginal fluid, vaginal cultures and measurement of lactate, succinate and cytokine levels in vaginal fluid. Smears deficient in lactobacilli and positive for clue cells were considered to indicate a diagnosis of bacterial vaginosis. Aerobic vaginitis was diagnosed if smears were deficient in lactobacilli, positive for cocci or coarse bacilli, positive for parabasal epithelial cells, and/or positive for vaginal leucocytes (plus their granular aspect). Genital complaints include red inflammation, yellow discharge, vaginal dyspareunia. Group B streptococci, escherichia coli, staphylococcus aureus and trichomonas vaginalis are frequently cultured. Vaginal lactate concentration is severely depressed in women with aerobic vaginitis, as in bacterial vaginosis, but vaginal succinate is not produced. Also in contrast to bacterial vaginosis, aerobic vaginitis produces a host immune response that leads to high production of interleukin-6, interleukin-1-beta and leukaemia inhibitory factor in the vaginal fluid. Aerobic vaginitis is associated with aerobic micro-organisms, mainly group B streptococci and E. coli. Its characteristics are different from those of bacterial vaginosis and elicit an important host response. The most severe form of aerobic vaginitis equals desquamative inflammatory vaginitis. In theory, aerobic vaginitis may be a better candidate than bacterial vaginosis as the cause of pregnancy complications, such as ascending chorioamnionitis, preterm rupture of the membranes and preterm delivery.

  5. Krytox Lubrication Tape Study. [fluorinated lubricating oil for video tape recorders

    NASA Technical Reports Server (NTRS)

    Lee, F.

    1978-01-01

    The use of Krytox, a fluorinated oil, as a tape surface lubricant was studied for a wideband video tape recorder. In spite of the 5 to 1 head wear reduction credited to the surface lubricant, the resultant head life fell short of the 1500 hour goal.

  6. Ubiquitous Graphene Electronics on Scotch Tape

    PubMed Central

    Chung, Yoonyoung; Ho Kim, Hyun; Lee, Sangryun; Lee, Eunho; Won Kim, Seong; Ryu, Seunghwa; Cho, Kilwon

    2015-01-01

    We report a novel concept of graphene transistors on Scotch tape for use in ubiquitous electronic systems. Unlike common plastic substrates such as polyimide and polyethylene terephthalate, the Scotch tape substrate is easily attached onto various objects such as banknotes, curved surfaces, and human skin, which implies potential applications wherein electronics can be placed in any desired position. Furthermore, the soft Scotch tape serves as an attractive substrate for flexible/foldable electronics that can be significantly bent, or even crumpled. We found that the adhesive layer of the tape with a relatively low shear modulus relaxes the strain when subjected to bending. The capacitance of the gate dielectric made of oxidized aluminum oxide was 1.5 μF cm−2, so that a supply voltage of only 2.5 V was sufficient to operate the devices. As-fabricated graphene transistors on Scotch tape exhibited high electron mobility of 1326 (±155) cm2 V−1 s−1; the transistors still showed high mobility of 1254 (±478) cm2 V−1 s−1 even after they were crumpled. PMID:26220874

  7. Intravesical Tension-Free Vaginal Tape Removal: Is There a Single Solution?

    PubMed Central

    Zakri, Rhana H.; Patel, Amit K.; John, Babbin S.; Shrotri, Nitin C.

    2011-01-01

    Stress urinary incontinence (SUI) affects 10–20% of women in the general population. Surgery for stress incontinence has been performed on women for over a century, but with the advent of new urogynaecological sling procedures for its management, urological surgeons are having to deal with an increasing number of patients presenting with associated complications. With no clarity on the full range of possible complications or certain consensus on their optimal management, the ideal treatment remains a decision for the individual surgeon. In view of this, we felt it of common interest to review the literature for the history of sling procedures, present commonly arising complications, and seek to answer the question in the title. PMID:22084797

  8. Oromaxillary Prosthetic Rehabilitation of a Maxillectomy Patient Using a Magnet Retained Two-Piece Hollow Bulb Definitive Obturator; A Clinical Report

    PubMed Central

    Mohamed Usman, Jafar Abdulla; Ayappan, Anuroopa; Ganapathy, Dhanraj; Nasir, Nilofer Nisha

    2013-01-01

    Resection of a malignant lesion involving the maxilla produces severe oromaxillary defect that can seriously jeopardize the normal phonetics of the patient. These defects are effectively managed by well-designed and fabricated obturator. This paper discusses the oromaxillary prosthetic rehabilitation of a maxillectomy patient using a magnet retained two-piece hollow bulb definitive obturator. PMID:23533823

  9. Health-related quality of life after maxillectomy: obturator rehabilitation compared with flap reconstruction.

    PubMed

    Breeze, J; Rennie, A; Morrison, A; Dawson, D; Tipper, J; Rehman, K; Grew, N; Snee, D; Pigadas, N

    2016-10-01

    Health-related quality of life (QoL) reported by patients has the potential to improve care after ablative surgery of the midface, as existing treatment algorithms still generally revolve around outcomes assessed traditionally only by clinicians. Decisions in particular relate to reconstruction with a flap compared with rehabilitation with an obturator, the need for adjuvant treatment, and morbidity related to the size of the defect. We prospectively collected health-related QoL assessments for 39 consecutive patients treated by maxillectomy between 01 January 2010 and 31 December 2014 using the University of Washington Quality of Life Questionnaire, and who had a mean (SD) duration of follow-up of 14 (4). We made sub-group analyses using paired t tests and analysis of variance (ANOVA) to compare reconstruction with a flap with rehabilitation with obturators, size of the vertical defect, and whether adjuvant treatment with radiotherapy or chemoradiotherapy adversely affected it. Overall there was a significant decrease in health-related QoL after treatment compared with before (p<0.001), but there was no significant difference in the effects of any of the paired reconstructive and rehabilitation treatments on it. Obturators remain an important option for rehabilitation in selected patients in addition to reconstruction with a flap. We found that neither increasing the size of the vertical defect (in an attempt to ensure clear margins) nor the use of postoperative radiotherapy seemed to have any adverse effect on QoL. More patients are required before we can conclude that the potential survival benefits of such measures may outweigh any adverse effects. Copyright © 2016 The British Association of Oral and Maxillofacial Surgeons. Published by Elsevier Ltd. All rights reserved.

  10. Clinical Characteristics of Aerobic Vaginitis and Its Association to Vaginal Candidiasis, Trichomonas Vaginitis and Bacterial Vaginosis

    PubMed Central

    Jahic, Mahira; Mulavdic, Mirsada; Nurkic, Jasmina; Jahic, Elmir; Nurkic, Midhat

    2013-01-01

    ABSTRACT Aim of the work: Examine clinical characteristics of aerobic vaginitis and mixed infection for the purpose of better diagnostic accuracy and treatment efficiency. Materials and methods: Prospective research has been conducted at Clinic for Gynecology and Obstetrics, Department for Microbiology and Pathology at Polyclinic for laboratory diagnostic and Gynecology and Obstetrics Department at Health Center Sapna. Examination included 100 examinees with the signs of vaginitis. Examination consisted of: anamnesis, clinical, gynecological and microbiological examination of vaginal smear. Results: The average age of the examinees was 32,62±2,6. Examining vaginal smears of the examinees with signs of vaginitis in 96% (N-96) different microorganisms have been isolated, while in 4% (N-4) findings were normal. AV has been found in 51% (N-51) of the examinees, Candida albicans in 17% (N-17), BV in 15% (N-15), Trichomonas vaginalis in 13% (N-13). In 21% (N-21) AV was diagnosed alone while associated with other agents in 30% (N-30). Most common causes of AV are E. coli (N-55) and E. faecalis (N-52). AV and Candida albicanis have been found in (13/30, 43%), Trichomonas vaginalis in (9/30, 30%) and BV (8/30, 26%). Vaginal secretion is in 70,05% (N-36) yellow coloured, red vagina wall is recorded in 31,13% (N-16) and pruritus in 72,54% (N-37). Increased pH value of vagina found in 94,10% (N-48). The average pH value of vaginal environment was 5,15±0,54 and in associated presence of AV and VVC, TV and BV was 5,29±0,56 which is higher value considering presence of AV alone but that is not statistically significant difference (p>0,05). Amino-odor test was positive in 29,94% (N-15) of associated infections. Lactobacilli are absent, while leukocytes are increased in 100% (N-51) of the examinees with AV. Conclusion: AV is vaginal infection similar to other vaginal infections. It is important to be careful while diagnosing because the treatment of AV differentiates from

  11. Clinical characteristics of aerobic vaginitis and its association to vaginal candidiasis, trichomonas vaginitis and bacterial vaginosis.

    PubMed

    Jahic, Mahira; Mulavdic, Mirsada; Nurkic, Jasmina; Jahic, Elmir; Nurkic, Midhat

    2013-12-01

    Examine clinical characteristics of aerobic vaginitis and mixed infection for the purpose of better diagnostic accuracy and treatment efficiency. Prospective research has been conducted at Clinic for Gynecology and Obstetrics, Department for Microbiology and Pathology at Polyclinic for laboratory diagnostic and Gynecology and Obstetrics Department at Health Center Sapna. Examination included 100 examinees with the signs of vaginitis. anamnesis, clinical, gynecological and microbiological examination of vaginal smear. The average age of the examinees was 32,62±2,6. Examining vaginal smears of the examinees with signs of vaginitis in 96% (N-96) different microorganisms have been isolated, while in 4% (N-4) findings were normal. AV has been found in 51% (N-51) of the examinees, Candida albicans in 17% (N-17), BV in 15% (N-15), Trichomonas vaginalis in 13% (N-13). In 21% (N-21) AV was diagnosed alone while associated with other agents in 30% (N-30). Most common causes of AV are E. coli (N-55) and E. faecalis (N-52). AV and Candida albicanis have been found in (13/30, 43%), Trichomonas vaginalis in (9/30, 30%) and BV (8/30, 26%). Vaginal secretion is in 70,05% (N-36) yellow coloured, red vagina wall is recorded in 31,13% (N-16) and pruritus in 72,54% (N-37). Increased pH value of vagina found in 94,10% (N-48). The average pH value of vaginal environment was 5,15±0,54 and in associated presence of AV and VVC, TV and BV was 5,29±0,56 which is higher value considering presence of AV alone but that is not statistically significant difference (p>0,05). Amino-odor test was positive in 29,94% (N-15) of associated infections. Lactobacilli are absent, while leukocytes are increased in 100% (N-51) of the examinees with AV. AV is vaginal infection similar to other vaginal infections. It is important to be careful while diagnosing because the treatment of AV differentiates from treatment of other vaginitis.

  12. Digital optical tape: Technology and standardization issues

    NASA Technical Reports Server (NTRS)

    Podio, Fernando L.

    1996-01-01

    During the coming years, digital data storage technologies will continue an aggressive growth to satisfy the user's need for higher storage capacities, higher data transfer rates and long-term archival media properties. Digital optical tape is a promising technology to satisfy these user's needs. As any emerging data storage technology, the industry faces many technological and standardization challenges. The technological challenges are great, but feasible to overcome. Although it is too early to consider formal industry standards, the optical tape industry has decided to work together by initiating prestandardization efforts that may lead in the future to formal voluntary industry standards. This paper will discuss current industry optical tape drive developments and the types of standards that will be required for the technology. The status of current industry prestandardization efforts will also be discussed.

  13. Post-Obturation pain following one-visit and two-visit root canal treatment in necrotic anterior teeth.

    PubMed

    Rao, K Nandan; Kandaswamy, Raghavendra; Umashetty, Girish; Rathore, Vishnu Pratap Singh; Hotkar, Chetan; Patil, Basanagouda S

    2014-04-01

    To investigate and compare the post-obturation pain after one-visit and two-visit root canal treatment in non-vital anterior teeth. One hundred forty eight patients requiring root canal therapy on permanent anterior non-vital teeth with single root were included in this study. Patients were randomly assigned to either the one-appointment or the twoappointment group. The standardized protocol for all the teeth involved local anesthesia, isolation and access, engine-driven rotary nickel-titanium canal instrumentation with 2.5% NaOCl irrigation and obturation. Teeth in group 1 (n = 74) were obturated during the first appointment by using laterally condensed gutta-percha and resin sealer. Teeth in group 2 (n = 74) were given closed dressing and were obturated during the second appointment, 7 to 14 days later. A modified Visual Analogue Scale was used to measure pain after 6 hours, 24 hours, 48 hours and 7 days after the treatment. Statistical analysis was done to compare groups at each interval by using an independent-samples t test. The incidence and intensity of post-obturation pain in both Group 'A' and Group 'B' gradually reduced over the study period. When the incidence of pain was compared in the single and two visit group, it was found that the single-visit group experienced slightly less pain than the two-visit group during all study intervals, but the difference found was not statistically significant. There was no difference in postoperative pain between patients treated in only one appointment and patients treated in two appointments. The majority of patients in both groups reported no pain or only minimal pain after 7 days of treatment. How to cite the article: Rao KN, Kandaswamy R, Umashetty G, Rathore VP, Hotkar C, Patil BS. Post-Obturation pain following one-visit and two-visit root canal treatment in necrotic anterior teeth. J Int Oral Health 2014;6(2):28-32.

  14. Imaging System for Vaginal Surgery.

    PubMed

    Taylor, G Bernard; Myers, Erinn M

    2015-12-01

    The vaginal surgeon is challenged with performing complex procedures within a surgical field of limited light and exposure. The video telescopic operating microscope is an illumination and imaging system that provides visualization during open surgical procedures with a limited field of view. The imaging system is positioned within the surgical field and then secured to the operating room table with a maneuverable holding arm. A high-definition camera and Xenon light source allow transmission of the magnified image to a high-definition monitor in the operating room. The monitor screen is positioned above the patient for the surgeon and assistants to view real time throughout the operation. The video telescopic operating microscope system was used to provide surgical illumination and magnification during total vaginal hysterectomy and salpingectomy, midurethral sling, and release of vaginal scar procedures. All procedures were completed without complications. The video telescopic operating microscope provided illumination of the vaginal operative field and display of the magnified image onto high-definition monitors in the operating room for the surgeon and staff to simultaneously view the procedures. The video telescopic operating microscope provides high-definition display, magnification, and illumination during vaginal surgery.

  15. Streptococcus agalactiae: a vaginal pathogen?

    PubMed

    Maniatis, A N; Palermos, J; Kantzanou, M; Maniatis, N A; Christodoulou, C; Legakis, N J

    1996-03-01

    The significance of Streptococcus agalactiae as an aetiological agent in vaginitis was evaluated. A total of 6226 samples from women who presented with vaginal symptoms was examined. The presence of >10 leucocytes/high-power field (h.p.f.) was taken to be the criterion of active infection. S. agalactiae was isolated from 10.1% of these samples. The isolation rates of other common pathogens such as Candida spp., Gardnerella vaginalis and Trichomonas spp. were 54.1%, 27.2% and 4.2%, respectively, in the same group of patients. In contrast, the isolation rates of these micro-organisms in the group of patients who had no infection (<10 leucocytes/h.p.f.) were 4.2%, 38.3%, 33% and 0.5%, respectively. In the majority of samples from which S. agalactiae was isolated, it was the sole pathogen isolated (83%) and its presence was associated with an inflammatory response in 80% of patients. Furthermore, the relative risk of vaginal infection with S. agalactiae (2.38) in patients with purulent vaginal discharge was greater than that of Candida spp. infection (1.41) and lower than that of Trichomonas spp. infection (8.32). These data suggest that S. agalactiae in symptomatic women with microscopic evidence of inflammation should be considered a causative agent of vaginitis.

  16. Towards a 1000 tracks digital tape recorder

    NASA Technical Reports Server (NTRS)

    Coutellier, J. M.; Castera, J. P.; Colineau, J.; Lehureau, J. C.; Maurice, F.; Hanna, C.

    1993-01-01

    As the demand for high data rate (up to 1 Gb/s), high density (down to 1 sq micron/bit) tape recorder increases, the main investigation trend is an improvement of the well known helical scan concept. The drawbacks of this technology are also well known; sophisticated mechanics, head to tape contact, and wear problems. In our fixed head approach, the recorder mechanics is made much more simple, but the complexity is turned towards the integrated magnetic components, which have to record and reproduce hundreds of tracks in parallel. Our multiplexed write inductive head and magneto-optical readout head will be described, and the global system performances evaluated.

  17. Textured substrate tape and devices thereof

    DOEpatents

    Goyal, Amit

    2006-08-08

    A method for forming a sharply biaxially textured substrate, such as a single crystal substrate, includes the steps of providing a deformed metal substrate, followed by heating above the secondary recrystallization temperature of the deformed substrate, and controlling the secondary recrystallization texture by either using thermal gradients and/or seeding. The seed is selected to shave a stable texture below a predetermined temperature. The sharply biaxially textured substrate can be formed as a tape having a length of 1 km, or more. Epitaxial articles can be formed from the tapes to include an epitaxial electromagnetically active layer. The electromagnetically active layer can be a superconducting layer.

  18. Accuracy testing of steel and electric groundwater-level measuring tapes: Test method and in-service tape accuracy

    USGS Publications Warehouse

    Fulford, Janice M.; Clayton, Christopher S.

    2015-10-09

    The calibration device and proposed method were used to calibrate a sample of in-service USGS steel and electric groundwater tapes. The sample of in-service groundwater steel tapes were in relatively good condition. All steel tapes, except one, were accurate to ±0.01 ft per 100 ft over their entire length. One steel tape, which had obvious damage in the first hundred feet, was marginally outside the accuracy of ±0.01 ft per 100 ft by 0.001 ft. The sample of in-service groundwater-level electric tapes were in a range of conditions—from like new, with cosmetic damage, to nonfunctional. The in-service electric tapes did not meet the USGS accuracy recommendation of ±0.01 ft. In-service electric tapes, except for the nonfunctional tape, were accurate to about ±0.03 ft per 100 ft. A comparison of new with in-service electric tapes found that steel-core electric tapes maintained their length and accuracy better than electric tapes without a steel core. The in-service steel tapes could be used as is and achieve USGS accuracy recommendations for groundwater-level measurements. The in-service electric tapes require tape corrections to achieve USGS accuracy recommendations for groundwater-level measurement.

  19. Tape-Drop Transient Model for In-Situ Automated Tape Placement of Thermoplastic Composites

    NASA Technical Reports Server (NTRS)

    Costen, Robert C.; Marchello, Joseph M.

    1998-01-01

    Composite parts of nonuniform thickness can be fabricated by in-situ automated tape placement (ATP) if the tape can be started and stopped at interior points of the part instead of always at its edges. This technique is termed start/stop-on-the-part, or, alternatively, tape-add/tape-drop. The resulting thermal transients need to be managed in order to achieve net shape and maintain uniform interlaminar weld strength and crystallinity. Starting-on-the-part has been treated previously. This paper continues the study with a thermal analysis of stopping-on-the-part. The thermal source is switched off when the trailing end of the tape enters the nip region of the laydown/consolidation head. The thermal transient is determined by a Fourier-Laplace transform solution of the two-dimensional, time-dependent thermal transport equation. This solution requires that the Peclet number Pe (the dimensionless ratio of inertial to diffusive heat transport) be independent of time and much greater than 1. Plotted isotherms show that the trailing tape-end cools more rapidly than the downstream portions of tape. This cooling can weaken the bond near the tape end; however the length of the affected region is found to be less than 2 mm. To achieve net shape, the consolidation head must continue to move after cut-off until the temperature on the weld interface decreases to the glass transition temperature. The time and elapsed distance for this condition to occur are computed for the Langley ATP robot applying PEEK/carbon fiber composite tape and for two upgrades in robot performance. The elapsed distance after cut-off ranges from about 1 mm for the present robot to about 1 cm for the second upgrade.

  20. Vaginitis: current microbiologic and clinical concepts.

    PubMed Central

    Hill, L V; Embil, J A

    1986-01-01

    Infectious vaginitis occurs when the normal vaginal flora is disrupted; it may arise when saprophytes overwhelm the host immune response, when pathogenic organisms are introduced into the vagina or when changes in substrate allow an imbalance of microorganisms to develop. Examples of these types of vaginitis include the presence of chronic fungal infection in women with an inadequate cellular immune response to the yeast, the introduction of trichomonads into vaginal epithelium that has a sufficient supply of glycogen, and the alteration in bacterial flora, normally dominated by Lactobacillus spp., and its metabolites that is characteristic of "nonspecific vaginitis". The authors review microbiologic and clinical aspects of the fungal, protozoal and bacterial infections, including the interactions of bacteria thought to produce nonspecific vaginitis, that are now recognized as causing vaginitis. Other causes of vaginitis are also discussed. PMID:3510698

  1. Vaginitis: current microbiologic and clinical concepts.

    PubMed

    Hill, L V; Embil, J A

    1986-02-15

    Infectious vaginitis occurs when the normal vaginal flora is disrupted; it may arise when saprophytes overwhelm the host immune response, when pathogenic organisms are introduced into the vagina or when changes in substrate allow an imbalance of microorganisms to develop. Examples of these types of vaginitis include the presence of chronic fungal infection in women with an inadequate cellular immune response to the yeast, the introduction of trichomonads into vaginal epithelium that has a sufficient supply of glycogen, and the alteration in bacterial flora, normally dominated by Lactobacillus spp., and its metabolites that is characteristic of "nonspecific vaginitis". The authors review microbiologic and clinical aspects of the fungal, protozoal and bacterial infections, including the interactions of bacteria thought to produce nonspecific vaginitis, that are now recognized as causing vaginitis. Other causes of vaginitis are also discussed.

  2. The effect of vaginal cream containing ginger in users of clotrimazole vaginal cream on vaginal candidiasis.

    PubMed

    Shabanian, Sheida; Khalili, Sima; Lorigooini, Zahra; Malekpour, Afsaneh; Heidari-Soureshjani, Saeid

    2017-01-01

    Vulvovaginal candidiasis is one of the most common infections of the genital tract in women that causes many complications. Therefore, we examined the clinical effect of ginger cream along with clotrimazole compared to vaginal clotrimazole alone in this study. This double-blind clinical trial was conducted on 67 women admitted to the Gynecology Clinic of Hajar Hospital with vaginal candidiasis. The patients were divided randomly into two groups of 33 and 34 people. The diagnosis was made according to clinical symptoms, wet smear, and culture. Ginger-clotrimazole vaginal cream 1% and clotrimazole vaginal cream 1% were administered to groups 1 and 2, respectively, once a day for 7 days and therapeutic effects and symptoms were evaluated in readmission. Data analysis was performed using SPSS version 22, t -test and Chi-square. The mean value of variables itching ( P > 0.05), burning ( P > 0.05), and cheesy secretion ( P < 0.05) in users of ginger-clotrimazole was less than the other group after the treatment. Recurrence in clotrimazole group was 48.5% and in ginger-clotrimazole group 51.2% during the 1-month follow-up with no significant difference. Study results showed that cream containing ginger and clotrimazole 1% was more effective and may be more useful than the clotrimazole to treat vaginal candidiasis.

  3. Fabrication of a 3D Printing Definitive Obturator Prosthesis: a Clinical Report.

    PubMed

    Tasopoulos, Theodoros; Kouveliotis, Georgios; Polyzois, Grigoris; Karathanasi, Vasiliki

    2017-03-01

    Digital technologies related to imaging and manufacturing provide the clinician with a wide variety of treatment options. Stereolithography (SLA) offers a simple and predictable way for an accurate reconstruction of congenital or acquired defects. A 65-years old cancer patient with non- keratinized squamous cell carcinoma of left maxillary sinus came for a prosthetic clinical evaluation. A bilateral maxillectomy was performed and the treatment plan included definite obturator prosthesis for the upper arch. CT data and 3D planning software were used to create a 3D printing plastic model of the defect. A wax pattern of the hollow bulb was fabricated and cured with heat-cured silicone soft liner. A final impression was obtained with the hollow bulb placed intraorally. The master cast was duplicated and the new cast was invested and reflasked. The flasks were opened, wax was boiled out and some space was created in the internal part of the obturator. Transparent heat cured acrylic resin was sandwiched with, at the inner part of the bulb, improving the retention between the acrylic denture base and the silicone based soft lining material. The patient was then placed on a 6-month recall. The five-year follow up consists of a chair side relining, when needed, of the definite removable prostheses. Maxillofacial surgery patients may develop postoperative complications such as trismus and pain. In these cases, the combination of digital technology and conventional techniques provide an accurate prosthetic restoration.

  4. Fabrication of a 3D Printing Definitive Obturator Prosthesis: a Clinical Report

    PubMed Central

    Kouveliotis, Georgios; Polyzois, Grigoris; Karathanasi, Vasiliki

    2017-01-01

    Introduction Digital technologies related to imaging and manufacturing provide the clinician with a wide variety of treatment options. Stereolithography (SLA) offers a simple and predictable way for an accurate reconstruction of congenital or acquired defects. Clinical case A 65-years old cancer patient with non- keratinized squamous cell carcinoma of left maxillary sinus came for a prosthetic clinical evaluation. A bilateral maxillectomy was performed and the treatment plan included definite obturator prosthesis for the upper arch. CT data and 3D planning software were used to create a 3D printing plastic model of the defect. A wax pattern of the hollow bulb was fabricated and cured with heat-cured silicone soft liner. A final impression was obtained with the hollow bulb placed intraorally. The master cast was duplicated and the new cast was invested and reflasked. The flasks were opened, wax was boiled out and some space was created in the internal part of the obturator. Transparent heat cured acrylic resin was sandwiched with, at the inner part of the bulb, improving the retention between the acrylic denture base and the silicone based soft lining material. The patient was then placed on a 6-month recall. The five-year follow up consists of a chair side relining, when needed, of the definite removable prostheses. Conclusion Maxillofacial surgery patients may develop postoperative complications such as trismus and pain. In these cases, the combination of digital technology and conventional techniques provide an accurate prosthetic restoration. PMID:28740271

  5. Pulsed radiofrequency treatment of articular branches of femoral and obturator nerves for chronic hip pain.

    PubMed

    Chye, Cien-Leong; Liang, Cheng-Loong; Lu, Kang; Chen, Ya-Wen; Liliang, Po-Chou

    2015-01-01

    Chronic hip pain is a common symptom experienced by many people. Often, surgery is not an option for patients with multiple comorbidities, and conventional drugs either have many side effects or are ineffective. Pulsed radiofrequency (PRF) is a new method in the treatment of pain. We attempt to compare the efficacy of PRF relative to conservative management for chronic hip pain. Between August 2011 and July 2013, 29 patients with chronic hip pain were divided into two groups (PRF and conservative treatment) according to consent or refusal to undergo PRF procedure. Fifteen patients received PRF of the articular branches of the femoral and obturator nerves, and 14 patients received conservative treatment. Visual analog scale (VAS), Oxford hip scores (OHS), and pain medications were used for outcome measurement before treatment and at 1 week, 4 weeks, and 12 weeks after treatment. At 1 week, 4 weeks, and 12 weeks after treatment initiation, improvements in VAS were significantly greater with PRF. Improvements in OHS were significantly greater in the PRF group at 1 week, 4 weeks, and 12 weeks. Patients in the PRF group also used less pain medications. Eight subjects in the conservative treatment group switched to the PRF group after 12 weeks, and six of them had >50% improvement. When compared with conservative treatment, PRF of the articular branches of the femoral and obturator nerves offers greater pain relief for chronic hip pain and can augment physical functioning.

  6. Photoelastic analysis to compare implant-retained and conventional obturator dentures

    NASA Astrophysics Data System (ADS)

    Goiato, Marcelo Coelho; Prado Ribeiro, Paula do; Pellizzer, Eduardo Piza; Pesqueira, Aldiéris Alves; Haddad, Marcela Filiè; dos Santos, Daniela Micheline; Moreno, Amália

    2012-06-01

    The use of photoelastic analysis contributes to the rehabilitation of patients with oral-sinus-nasal sequelae, which in turn affect important functions such as chewing, swallowing, and speech. The prosthetic rehabilitation with implant-retained dentures is a suitable treatment option. The purpose of this study was to verify, by using a photoelastic analysis, the stress distribution in implant-retained palatal obturator dentures (relined or not) associated with different attachment systems (O-ring, bar-clip, and bar-clip associated with distally placed O-rings). Two photoelastic models were obtained from an experimental maxillary cast presenting an oral-nasal communication. One model had two 13-mm length implants placed on the left region. A total of eight colorless maxillary obturators were fabricated and subsequently four of them were relined with soft silicone soft, and three had attachment systems associated. The assembly (model/attachment system/prosthesis) was positioned in a circular polariscope and a 100-N load was applied at 10 mm/s. The results showed that the denture relining influenced the distribution and amount of stress on the models. The O-ring group displayed the lowest stress levels, followed by bar-clip system associated with distally placed O-rings and bar-clip groups.

  7. A comparison of root surface temperatures using different obturation heat sources.

    PubMed

    Lee, F S; Van Cura, J E; BeGole, E

    1998-09-01

    This study compared root surface temperatures produced during warm vertical obturation using the System B Heat Source (SB), the Touch 'n Heat device (TH), and a flame-heated carrier (FH). The root canals of 30 maxillary incisor, premolar, and mandibular incisor teeth were prepared; divided into three groups; and obturated using each heat source. A thermocouple placed 2 mm below the cementoenamel junction transferred the temperature rise on the external root surface to a digital thermometer. SB surface temperature rise was < 10 degrees C for all experimental teeth. TH temperature rise in maxillary incisors and premolars was < 10 degrees C; however, > 10 degrees C was observed for mandibular incisors. FH produced a > 10 degrees C surface temperature rise in all experimental teeth. The critical level of root surface heat required to produce irreversible bone damage is believed to be > 10 degrees C. The findings of this study suggest that warm vertical condensation with the SB should not damage supporting periradicular tissues. However, caution should be used with TH and FH on mandibular incisors.

  8. Premenarchal, recurrent vaginal discharge associated with an incomplete obstructing longitudinal vaginal septum.

    PubMed

    Hansen, Keith A; DeWitt, Jason

    2005-12-01

    To describe an unusual, premenarchal presentation of an obstructive vaginal anomaly. Case Report. University Medical Center. Premenarchal subject Vaginogram, vaginal septum resection. Vaginal septum resection with resolution of vaginal discharge. This case demonstrates some of the typical features of uterus didelphys bicollis with incomplete obstructing hemivagina, but had a unique presentation with premenarchal, recurrent vaginal discharge. Typically, patients with an obstructing mullerian anomaly present after menarche with pelvic pain and a mass. The vaginogram assists in the preoperative definition of abnormal anatomy which allows the surgeon to develop the most appropriate surgical approach. Resection of this incompletely obstructing vaginal septum resulted in resolution of the recurrent vaginal discharge.

  9. 21 CFR 884.3575 - Vaginal pessary.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Vaginal pessary. 884.3575 Section 884.3575 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL... Vaginal pessary. (a) Identification. A vaginal pessary is a removable structure placed in the vagina to...

  10. 21 CFR 884.5920 - Vaginal insufflator.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Vaginal insufflator. 884.5920 Section 884.5920 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED... § 884.5920 Vaginal insufflator. (a) Identification. A vaginal insufflator is a device used to treat...

  11. Idea Bank: Duct Tape Note Twister

    ERIC Educational Resources Information Center

    McHenry, Molly

    2008-01-01

    In this article, the author relates how she observed a middle school math teacher deliver a miserable class. She realized that she did the same thing to her music students. To engage her students, she developed "Note Twister," a music reading game using duct tape to form musical notes and the basic premise behind the game,…

  12. A COMPARATIVE STUDY OF VIDEO TAPE RECORDINGS.

    ERIC Educational Resources Information Center

    WIENS, JACOB H.

    THE COMPARATIVE EFFECTIVENESS OF PRESENTLY AVAILABLE VIDEO TAPE MACHINES IS REPORTED, FOR THE CONVENIENCE OF SCHOOL ADMINISTRATORS PLANNING TO USE SUCH EQUIPMENT IN EDUCATIONAL PROGRAMS. TESTS WERE CONDUCTED AT THE WIENS ELECTRONIC LABORATORIES. MACHINE BRANDS TESTED WERE AMPEX, CONCORD, MACHTRONICS, PRECISION, RCA, SONY, AND WOLLENSAK. A DETAILED…

  13. Red Tape: Its Origins, Uses, and Abuses.

    ERIC Educational Resources Information Center

    Kaufman, Herbert

    Red tape, particularly with reference to administration in the federal government, is described, and suggestions that have been proposed for improvement are explored. Among the frustrations that are met in dealing with government are duplicative and contradictory requirements of different agencies, restrictions imposed for announced ends that are…

  14. Distanced Data: Transcribing Other People's Research Tapes

    ERIC Educational Resources Information Center

    Tilley, Susan A.; Powick, Kelly D.

    2004-01-01

    In this article, we report on our qualitative study involving eight individuals hired to transcribe research tapes in university contexts. We consider issues of data analysis and data trustworthiness and the implications for both when transcription is assigned to someone other than the researcher. We explore the challenges transcribers faced…

  15. Artificial Intelligence Controls Tape-Recording Sequence

    NASA Technical Reports Server (NTRS)

    Schwuttke, Ursula M.; Otamura, Roy M.; Zottarelli, Lawrence J.

    1989-01-01

    Developmental expert-system computer program intended to schedule recording of large amounts of data on limited amount of magnetic tape. Schedules recording using two sets of rules. First set incorporates knowledge of locations for recording of new data. Second set incorporates knowledge about issuing commands to recorder. Designed primarily for use on Voyager Spacecraft, also applicable to planning and sequencing in industry.

  16. "Space slitter" for film or tape

    NASA Technical Reports Server (NTRS)

    Johnson, W. H.

    1978-01-01

    Device cuts film or tape into strips by guiding film in channel under cutting blades. Device is operated by lifting pressure bar to insert blades into film. Film is then pulled through blades. Cutter has potential uses in advertising, commercial art, and publishing fields.

  17. Digital Audio Tape: Yet Another Archival Media?

    ERIC Educational Resources Information Center

    Vanker, Anthony D.

    1989-01-01

    Provides an introduction to the technical aspects of digital audiotape and compares it to other computer storage devices such as optical data disks and magnetic tape cartridges in terms of capacity, transfer rate, and cost. The current development of digital audiotape standards is also discussed. (five references) (CLB)

  18. Analysis of particulates on tape lift samples

    NASA Astrophysics Data System (ADS)

    Moision, Robert M.; Chaney, John A.; Panetta, Chris J.; Liu, De-Ling

    2014-09-01

    Particle counts on tape lift samples taken from a hardware surface exceeded threshold requirements in six successive tests despite repeated cleaning of the surface. Subsequent analysis of the particle size distributions of the failed tests revealed that the handling and processing of the tape lift samples may have played a role in the test failures. In order to explore plausible causes for the observed size distribution anomalies, scanning electron microscopy (SEM), energy dispersive X-ray spectroscopy (EDX), and time-of-flight secondary ion mass spectrometry (ToF-SIMS) were employed to perform chemical analysis on collected particulates. SEM/EDX identified Na and S containing particles on the hardware samples in a size range identified as being responsible for the test failures. ToF-SIMS was employed to further examine the Na and S containing particulates and identified the molecular signature of sodium alkylbenzene sulfonates, a common surfactant used in industrial detergent. The root cause investigation suggests that the tape lift test failures originated from detergent residue left behind on the glass slides used to mount and transport the tape following sampling and not from the hardware surface.

  19. Heat reflecting tape for thermoelectric converter

    DOEpatents

    Purdy, David L.

    1977-01-01

    Threads are interlaced with thermoelectric wires to provide a woven cloth in tape form, there being an intermediate layer of heat radiation reflecting material (e.g., aluminum foil) insulated electrically from said wires, which are of opposite thermoelectric polarity and connected as a plurality of thermocouples.

  20. Tape It Yourself: Videotapes for Teacher Education

    ERIC Educational Resources Information Center

    Ebsworth, Miriam Eistein; Feknous, Barbara; Loyet, Dianne; Zimmerman, Spencer

    2004-01-01

    This paper describes the development and implementation of a series of videotapes of ESL classes for a pre-service teacher education program grounded in experiential learning theory. The videos included footage of ESL classrooms, and tapes edited and supplemented with interviews of ESL teachers. Our experience demonstrates that-with relatively low…

  1. A study of tape adhesive strength on endotracheal tubes.

    PubMed

    Fenje, N; Steward, D J

    1988-03-01

    A method of assessing the adhesive bond of tapes used to secure endotracheal (ET) tubes is described. Five kinds of tape and six different ET tubes including two silicone rubber, wire-reinforced tubes were tested. There are significant differences in the adhesive strength of different tapes, and in the adhesive bond formed by different ET tube materials. On the Portex clear ET tube, silk tape adhered best (p less than 0.001), followed by waterproof, cloth, dermiclear, and micropore tapes. Adhesive bonding by silk tape was significantly greater (p less than 0.001) for the three clear ET tubes (Portex clear, NCC clear, and Portex ivory) than for the Portex blue and the silicone rubber, wire-reinforced ET tubes. All tapes showed very poor or negligible adhesion to the Sheridan and Portex reinforced ET tubes. Adhesion to these tubes was greatly improved by wrapping them tightly with an "op site" dressing prior to applying tape.

  2. Effectiveness of functional ankle taping for judo athletes: a comparison between judo bandaging and taping.

    PubMed Central

    Yamamoto, T; Kigawa, A; Xu, T

    1993-01-01

    This study was conducted to compare the effectiveness of the traditional method of ankle bandaging and the new method of ankle taping for judo athletes in Japan, and to introduce a functionally effective taping method for judo players. Four university judo athletes with ankle instability were selected to undertake radiography of the ankles before and after exercise, with bandaging at one time and taping at the other. Talar tilt (TT) angles were measured in order to compare the ankle-supporting effects. The results showed that the old ankle bandaging method had no role in eliminating the talar tilt during judo practice. In contrast, the new taping method was more effective in eliminating the talar tilt and supporting the involved ankles both mechanically and functionally. Images Figure 1 Figure 2 Figure 3 PMID:8358580

  3. Editing of EIA coded, numerically controlled, machine tool tapes

    NASA Technical Reports Server (NTRS)

    Weiner, J. M.

    1975-01-01

    Editing of numerically controlled (N/C) machine tool tapes (8-level paper tape) using an interactive graphic display processor is described. A rapid technique required for correcting production errors in N/C tapes was developed using the interactive text editor on the IMLAC PDS-ID graphic display system and two special programs resident on disk. The correction technique and special programs for processing N/C tapes coded to EIA specifications are discussed.

  4. Optical clearing of vaginal tissues

    NASA Astrophysics Data System (ADS)

    Chang, Chun-Hung; Myers, Erinn M.; Kennelly, Michael J.; Fried, Nathaniel M.

    2017-02-01

    Near-IR laser energy in conjunction with applied tissue cooling is being investigated for thermal remodeling of endopelvic fascia during minimally invasive treatment of female stress urinary incontinence. Previous simulations of light transport, heat transfer, and tissue thermal damage have shown that a transvaginal approach is more feasible than a transurethral approach. However, undesirable thermal insult to vaginal wall was predicted. This study explores whether an optical clearing agent (OCA) can improve optical penetration depth and completely preserve vaginal wall during subsurface treatment of endopelvic fascia. Several OCA mixtures were tested, and 100% glycerol was found to be optimal. Optical transmission studies, optical coherence tomography, reflection spectroscopy, and computer simulations of thermal damage to tissue using glycerol were performed. The OCA produced a 61% increase in optical transmission through porcine vaginal wall at 37 °C after 30 min. Monte Carlo (MC) light transport, heat transfer, and Arrhenius integral thermal damage simulations were performed. MC model showed improved energy deposition in endopelvic fascia using OCA. Without OCA, 62, 37, and 1% of energy was deposited in vaginal wall, endopelvic fascia, and urethral wall, compared with 50, 49, and 1% with OCA. Use of OCA also yielded 0.5 mm increase in treatment depth, allowing potential thermal tissue remodeling at 3 mm depth.

  5. Effect of different intraorifice barriers on the fracture resistance of roots obturated with Resilon or gutta-percha.

    PubMed

    Nagas, Emre; Uyanik, Ozgur; Altundasar, Emre; Durmaz, Veli; Cehreli, Zafer C; Vallittu, Pekka K; Lassila, Lippo V J

    2010-06-01

    This study investigated and compared the root reinforcement potential of 3 different intraorifice barriers (mineral trioxide aggregate [MTA], resin-modified glass ionomer cement [Vitremer], and fiber-reinforced composite [FRC]) placed over root canals obturated with gutta-percha or Resilon. Crowns of 80 extracted human mandibular premolars were sectioned off to obtain 14-mm-long root specimens. After preparation of root canals with nickel-titanium rotary files, the roots were obturated with either the Resilon/Epiphany system or gutta-percha + AH Plus sealer. In both obturation groups, specimens were further subgrouped with respect to the intraorifice barrier material placed after removal of 3-mm coronal portion of the root fillings: (1) MTA, (2) Vitremer, and (3) FRC. The specimens were loaded vertically at 1 mm/min crosshead speed until vertical root fracture occurred. Results were evaluated statistically with two-way analysis of variance and Tukey tests. Fracture resistance of roots was significantly affected by the type of intraorifice barrier (P < .05), but not by the type of obturation system used (P > .05). The use of Vitremer and FRC significantly improved the fracture resistance, whereas MTA did not exhibit any reinforcing effect as an intraorifice barrier. Copyright 2010 American Association of Endodontists. Published by Elsevier Inc. All rights reserved.

  6. An ex vivo comparison of pressures within dental pulp space using conventional anesthetic technique versus needle-mounted obturator.

    PubMed

    Grubbs, S Lee; Alley, Larry W; Eleazer, Paul D

    2014-07-01

    The intrapulpal (IP) injection technique is 1 of several ways of obtaining profound anesthesia. There is evidence to suggest that pressure is the primary factor in obtaining anesthesia using IP injection. This is an ex vivo comparison of pressures within dental pulp space using the conventional anesthetic technique versus a needle-mounted obturator technique. Twenty extracted anterior and premolar teeth were accessed with a high-speed 169L bur. A saline-filled tube connected to a digital pressure gauge was attached to the apical 10 mm of each tooth in a fixed mount. One operator performed all the injections under moderate pressure. Each tooth was injected twice; first, the tooth was given an IP injection with a normal setup, and then the same tooth was given an IP injection with the modified obturator syringe. The pressure at the apex was recorded for each tooth. A paired sample t test was completed to determine statistical significance. The pressure generated was considerably higher for the obturator group in every tooth when compared with the normal group (P < .001). IP injection with the obturator resulted in increased pressure at the apex of each tooth. This pressure increase may allow for increased anesthesia when IP injections are indicated. Copyright © 2014 American Association of Endodontists. Published by Elsevier Inc. All rights reserved.

  7. Effectiveness of spinal anesthesia combined with obturator nerve blockade in preventing adductor muscle contraction during transurethral resection of bladder tumor

    PubMed Central

    Alavi, Cyrus Emir; Asgari, Seyed Alaeddin; Falahatkar, Siavash; Rimaz, Siamak; Naghipour, Mohammadreza; Khoshrang, Hossein; Jafari, Mehdi; Herfeh, Nadia

    2017-01-01

    Objective To determine whether spinal anesthesia combined with obturator nerve blockade (SOB) is effective in preventing obturator nerve stimulation, jerking and bladder perforation during transurethral resection of bladder tumor (TURBT). Material and methods In this clinical trial, 30 patients were randomly divided into two groups: spinal anesthesia (SA) and SOB. In SA group, 2.5 cc of 0.5% bupivacaine was injected intrathecally using a 25-gauge spinal needle and in SOB after spinal anesthesia, a classic obturator nerve blockade was performed by using nerve stimulation technique. Results There was a statistically significant difference between jerking in both groups (p=0.006). During the TURBT, surgeon satisfaction was significantly higher in SOB group compared to SA group (p=0.006). There was no significant correlation between sex, patient age and location of bladder tumor between the groups (p>0.05). Conclusion Obturator nerve blockade by using 15 cc lidocaine 1% is effective in preventing adductor muscle spasms during TURBT. PMID:29201516

  8. Ability of New Obturation Materials to Improve the Seal of the Root Canal System – A Review

    PubMed Central

    Zhang, Wei; Olsen, Mark; De-Deus, Gustavo; Eid, Ashraf A.; Chen, Ji-hua; Pashley, David H.; Tay, Franklin R.

    2014-01-01

    Objectives New obturation biomaterials have been introduced over the past decade to improve the seal of the root canal system. However, it is not clear whether they have really produced a three-dimensional impervious seal that is important for reducing diseases associated with root canal treatment. Methods A review of the literature was performed to identify models that have been employed for evaluating the seal of the root canal system. Results and Significance In-vitro and in-vivo models are not totally adept at quantifying the seal of root canals obturated with classic materials. Thus, one has to resort to clinical outcomes to examine whether there are real benefits associated with the use of recently-introduced materials for obturating root canals. However, there is no facile answer because endodontic treatment outcomes are influenced by a host of other predictors that are more likely to take precedence over the influence of obturation materials. From the perspective of clinical performance, classic root filling materials have stood the test of time. Because many of the recently-introduced materials are so new, there is not enough evidence yet to support their ability to improve clinical performance. This emphasizes the need to translate anecdotal information into clinically relevant research data on new biomaterials. PMID:24321349

  9. Three tumor patients with total maxillectomy rehabilitated with implant-supported frameworks and maxillary obturators: a follow-up report.

    PubMed

    Örtorp, Anders

    2010-12-01

    Few reports are available on treatment using implant-supported frameworks with maxillary obturators after total maxillectomy on tumor patients. To describe, evaluate, and report the clinical and radiographic performance of implant-supported frameworks and maxillary obturators after maxillectomy during the first years of function. Three patients with cancer in the maxillary region treated by total maxillectomy were rehabilitated. Seventeen dental and two craniofacial implants were installed, and the patients each received implant-supported, screw-retained, three-unit frameworks with a U-shaped bar and obturators retained by four magnetic attachments. Clinical and radiographic data were collected up to 7 years of follow-up. The frequency of complications was low. Two craniofacial implants and one dental implant were loose and removed at abutment connection. No implants were lost after framework connection, and the mean marginal bone loss was small. Within the limitations of this report, dental implants are useful for rehabilitation of total maxillectomy patients, and a three-unit, screw-retained, implant-supported framework with maxillary obturator retained by magnetic attachment is a successful treatment concept for this patient group. © 2009, Copyright the Author. Journal Compilation © 2010, Wiley Periodicals, Inc.

  10. Rehabilitation of a One-day-Old Neonate with Cleft Lip and Palate using Palatal Obturator: A Case Report.

    PubMed

    Bansal, Rajesh; Kumar Pathak, Ashish; Bhatia, Baldev; Gupta, Sailesh; Kumar Gautam, Keshav

    2012-05-01

    Feeding a neonate with a complete cleft lip and palate is difficult pursuit due to communication between oral cavity and nasal cavity. A multidisciplinary approach is required to manage the complex problems involved in case of such neonates and their families. Present case is of a 1-day-old neonate having complete bilateral cleft lip and palate for which palatal obturator was constructed. A stepwise simple, easy and uncomplicated procedure for making accurate impressions, maxillary cast and fabrication of palatal obturator in infants with cleft lip and palate has been presented. The objective to present this case report is to emphasize the fact that how these palatal obturators /plates help in feeding, speech/language development, presurgical orthopedics and prevent other associated otorhinolaryngeal problems. How to cite this article: Bansal R, Pathak AK, Bhatia B, Gupta S, Gautam KK. Rehabilitation of a One-day Old Neonate with Cleft Lip and Palate using Palatal Obturator: A Case Report. Int J Clin Pediatr Dent 2012;5(2):145-147.

  11. [Aerobic vaginitis--diagnostic problems and treatment].

    PubMed

    Romanik, Małgorzata; Wojciechowska-Wieja, Anna; Martirosian, Gayane

    2007-06-01

    The diagnostic criteria and treatment of aerobic vaginitis--AV--have been summarized in this review. An expansion of mixed aerobic microflora, especially Group B Streptococcus--GBS, Escherichia coli--E. coli, Enterococcus spp., and the development of inflammation of the vaginal mucous membrane due to a decreasing amount of Lactobacillus spp., have been observed in women with AV. Disruptions of the vaginal ecosystem during AV cause an increase in pH to >6, a decrease in lactates concentration and an increase in proinflammatory cytokines concentration in vaginal discharge. An optimal treatment scheme for AV, which includes antibacterial agents and simultaneously normalizes the vaginal ecosystem, has not been established until today.

  12. 48 CFR 908.7116 - Electronic data processing tape.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 48 Federal Acquisition Regulations System 5 2010-10-01 2010-10-01 false Electronic data processing... Electronic data processing tape. (a) Acquisitions of electronic data processing tape by DOE offices shall be in accordance with FPMR 41 CFR 101-26.508. (b) Acquisitions of electronic data processing tape by...

  13. 48 CFR 908.7116 - Electronic data processing tape.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 48 Federal Acquisition Regulations System 5 2011-10-01 2011-10-01 false Electronic data processing... Electronic data processing tape. (a) Acquisitions of electronic data processing tape by DOE offices shall be in accordance with FPMR 41 CFR 101-26.508. (b) Acquisitions of electronic data processing tape by...

  14. 48 CFR 908.7116 - Electronic data processing tape.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... 48 Federal Acquisition Regulations System 5 2013-10-01 2013-10-01 false Electronic data processing... Electronic data processing tape. (a) Acquisitions of electronic data processing tape by DOE offices shall be in accordance with FPMR 41 CFR 101-26.508. (b) Acquisitions of electronic data processing tape by...

  15. 48 CFR 908.7116 - Electronic data processing tape.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... 48 Federal Acquisition Regulations System 5 2014-10-01 2014-10-01 false Electronic data processing... Electronic data processing tape. (a) Acquisitions of electronic data processing tape by DOE offices shall be in accordance with FPMR 41 CFR 101-26.508. (b) Acquisitions of electronic data processing tape by...

  16. 48 CFR 908.7116 - Electronic data processing tape.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... 48 Federal Acquisition Regulations System 5 2012-10-01 2012-10-01 false Electronic data processing... Electronic data processing tape. (a) Acquisitions of electronic data processing tape by DOE offices shall be in accordance with FPMR 41 CFR 101-26.508. (b) Acquisitions of electronic data processing tape by...

  17. Dialects for the Stage: A Manual and Two Casette Tapes.

    ERIC Educational Resources Information Center

    Machlin, Evangeline

    This document contains a manual and two cassette tapes designed to help actors and actresses learn to speak various dialects. The tapes and the manual are arranged for the play-it-and-say-it method of dialect acquisition. The first three parts discuss the tapes and the manual in general, the dialect texts and dialect data, and the steps involved…

  18. Micro-Teaching Tapes in Anatomy and Physiology.

    ERIC Educational Resources Information Center

    Stencel, John E.

    1981-01-01

    Outlines the development and use of micro-teaching tapes as a means of supplemental instruction for college anatomy and physiology classes. Tapes include brief explanations of difficult concepts taken from lectures as students listen to cassette tapes and fill in blanks, or answer questions. (DS)

  19. 75 FR 14628 - Pressure Sensitive Plastic Tape From Italy; Determination

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-03-26

    ... Plastic Tape From Italy; Determination On the basis of the record \\1\\ developed in the subject five-year... pressure sensitive plastic tape from Italy would be likely to lead to continuation or recurrence of... Publication 4128 (March 2010), entitled Pressure Sensitive Plastic Tape from Italy: Investigation No. AA1921...

  20. Kinesio taping or sham taping in knee osteoarthritis? A randomized, double-blind, sham-controlled trial.

    PubMed

    Kocyigit, Figen; Turkmen, Mehmet Besir; Acar, Merve; Guldane, Nezahat; Kose, Tugce; Kuyucu, Ersin; Erdil, Mehmet

    2015-11-01

    To compare effects of kinesio taping with sham taping at the end of 3 consecutive taping periods in knee osteoarthritis. 41 patients diagnosed with knee osteoarthritis according to American College of Rheumatology were randomized to receive either KT or sham taping. Baseline evaluations included a visual analog scale (VAS) for activity and nocturnal pain, Lequesne index for functional assessment and Nottingham Health Profile (NHP) for the quality of life. Taping was applied every four days, three times, and all of the assessments were repeated at the end of the treatment period. In both groups VAS for activity pain, VAS for nocturnal pain, Lequesne index score, NHP score decreased significantly. NHP energy scores were different significantly between the groups in favor of sham taping at the end of the 12-day period. Our findings indicate inconclusive evidence of a beneficial effect of kinesio taping over sham taping in knee osteoarthritis. Copyright © 2015 Elsevier Ltd. All rights reserved.

  1. True vaginal prolapse in a bitch.

    PubMed

    Alan, M; Cetin, Y; Sendag, S; Eski, F

    2007-08-01

    Frequently, vaginal fold prolapse is the protrusion of edematous vaginal tissue into and through the opening of the vulva occurring during proestrus and estrus stages of the sexual cycle. True vaginal prolapse may occur near parturition, as the concentration of serum progesterone declines and the concentration of serum oestrogen increases. In the bitch, this type of true vaginal prolapse is a very rare condition. This short communication describes a 5-year-old female, cross-breed dog in moderate condition, weighing 33 kg, with distocia and true vaginal prolapse. Abdominal palpation and transabdominal ultrasonography revealed live and dead foetuses in the uterine horns. One dead and four live fetuses were removed from uterus by cesarean section. The ovariohysterectomy was performed after repositioning the vaginal wall with a combination of traction from within the abdomen and external manipulation through the vulva. Re-occurrence of a vaginal prolapse was not observed and the bitch recovered completely after the surgical therapy. Compared to other vaginal disorders, vaginal prolapse is an uncommon condition in the bitch. In the present case, extreme tenesmus arising from distocia may have predisposed to the vaginal prolapse. The cause of dystocia was probably the disposition of the first foetus. We concluded that the vaginal prolapse was the result of dystocia in the present case.

  2. Vaginal metastasis presenting as postmenopausal bleeding.

    PubMed

    Ng, Qiu Ju; Namuduri, Rama Padma; Yam, Kwai Lam; Lim-Tan, Soo Kim

    2015-08-01

    Vaginal cancer is rare worldwide and represents 2% of all gynaecological cancers in Singapore. Primary vaginal malignancies are rare and vaginal metastases constitute the majority of vaginal malignancies. Most of these metastases arise from the cervix, endometrium or ovary, although they can also metastasise from distant sites such as the colon, breast and pancreas. We report a rare case of vaginal metastasis in a patient with previous gastric and rectal adenocarcinomas. An 89-year-old woman with a history of gastric and rectal malignancy presented with postmenopausal bleeding. A 2-cm vaginal tumour at the introitus was discovered upon examination. This case demonstrates the importance of performing a gynaecological examination during follow-up for patients with a history of malignancy. The prognosis for vaginal metastasis is poor, as it is often associated with disseminated disease. Depending on the extent of the lesions, radiotherapy or surgery can be considered.

  3. Paper Tape Prevents Foot Blisters: A Randomized Prevention Trial Assessing Paper Tape in Endurance Distances II (Pre-TAPED II).

    PubMed

    Lipman, Grant S; Sharp, Louis J; Christensen, Mark; Phillips, Caleb; DiTullio, Alexandra; Dalton, Andrew; Ng, Pearlly; Shangkuan, Jennifer; Shea, Katherine; Krabak, Brian J

    2016-09-01

    To determine whether paper tape prevents foot blisters in multistage ultramarathon runners. Multisite prospective randomized trial. The 2014 250-km (155-mile) 6-stage RacingThePlanet ultramarathons in Jordan, Gobi, Madagascar, and Atacama Deserts. One hundred twenty-eight participants were enrolled: 19 (15%) from the Jordan, 35 (27%) from Gobi, 21 (16%) from Madagascar, and 53 (41%) from the Atacama Desert. The mean age was 39.3 years (22-63) and body mass index was 24.2 kg/m (17.4-35.1), with 31 (22.5%) females. Paper tape was applied to a randomly selected foot before the race, either to participants' blister-prone areas or randomly selected location if there was no blister history, with untaped areas of the same foot used as the control. Development of a blister anywhere on the study foot. One hundred six (83%) participants developed 117 blisters, with treatment success in 98 (77%) runners. Paper tape reduced blisters by 40% (P < 0.01, 95% confidence interval, 28-52) with a number needed to treat of 1.31. Most of the study participants had 1 blister (78%), with most common locations on the toes (n = 58, 50%) and heel (n = 27, 23%), with 94 (80%) blisters occurring by the end of stage 2. Treatment success was associated with earlier stages [odds ratio (OR), 74.9, P < 0.01] and time spent running (OR, 0.66, P = 0.01). Paper tape was found to prevent both the incidence and frequency of foot blisters in runners.

  4. In vitro comparison of gutta-percha-filled area percentages in root canals instrumented and obturated with different techniques.

    PubMed

    Yilmaz, Ayca; Karagoz-Kucukay, Isil

    2017-01-01

    To evaluate the efficacy of different obturation techniques in root canals instrumented either by hand or rotary instruments with regard to the percentage of gutta- percha-filled area (PGFA). One hundred and sixty extracted mandibular premolars with single, straight root canals were studied. Root canals were prepared to an apical size of 30 by hand with a modified crown-down technique or the ProTaper and HEROShaper systems. Teeth were divided into eight groups (n=20) according to the following instrumentation and obturation techniques: G1: Hand files+lateral condensation (LC), G2: Hand files+Thermafil, G3: ProTaper+LC, G4: ProTaper+single-cone, G5: ProTaper+ProTaper-Obturator, G6: HEROShaper+LC, G7: HEROShaper+single-cone, G8: HEROShaper+HEROfill. Horizontal sections were cut at 1, 3, 5, 7, 9, 11 and 13 mm from the apical foramen. A total of 1120 sections obtained were digitally photographed under a stereomicroscope set at 48X magnification. The cross-sectional area of the canal and the gutta-percha was measured by digital image analysis and the PGFA was calculated for each section. The mean of the PGFA in Thermafil (G2), ProTaper-Obturator (G5) and HEROfill (G8) groups was significantly higher than the other groups. In G3 and G4, PGFA showed no significant difference in the apical segments whereas PGFA was significantly higher at the middle and coronal segments in G3. In G6 and G7, PGFA showed no significant difference in the apical and middle segments whereas PGFA was significantly higher at the coronal segments in G6. The carrier-based gutta-percha obturation systems revealed significantly higher PGFA in comparison to single-cone and lateral condensation techniques.

  5. Neurofibroma involving obturator nerve mimicking an adnexal mass: a rare case report and PRISMA-driven systematic review.

    PubMed

    Chao, Wei-Ting; Liu, Chia-Hao; Chen, Yi-Jen; Wu, Hua-Hsi; Chuang, Chi-Mu; Wang, Peng-Hui

    2018-02-09

    Pelvic masses are a common gynecologic problem, and majority of them are diagnosed as ovarian tumors finally. Sometimes, it is hard to distinguish the origin of these pelvic masses. The following case is a solitary neurofibroma arising from the right-side obturator nerve, which was impressed as a right-side ovarian tumor initially. We reported this case, and also performed a PRISMA-driven systematic review to summary the similar cases in the literature. This review includes image, molecular and pathological findings and outcome of neurofibroma. A 33-year-old woman with a regular menstrual period denied any symptoms or signs. During her physical check-up, image examination revealed a right-side heterogeneous pelvic mass; it was suggestive of a complex of right-side ovarian tumor. A provisional diagnosis of retroperitoneal pelvic mass, probably a benign ovarian tumor, was made. Excision of the right-side pelvic mass was performed. We sent the specimens for frozen pathology, which indicated neurofibroma and lipomatous tumor and that the possibility of liposarcoma cannot be excluded. A segment of the obturator nerve was attached to the tumor and was severed. A right-side obturator nerve tear during tumor excision was observed, and a neurosurgeon was consulted for obturator nerve grafting and repair. The patient complained of mild weakness and paresthesia affecting the right leg, and we consulted a rehabilitation doctor for neuron injury. The patient's recovery was uneventful, and she was discharged eight days after the drain was removed. Further rehabilitation treatment was arranged. A neurofibroma is an uncommon pelvic retroperitoneal tumor, and it can be misdiagnosed as an adnexal mass. To our knowledge, this is a rare case of a solitary neurofibroma arising from the obturator nerve. It usually does not have any neurological deficit. We present this case to demonstrate that pelvic neurofibroma can be mistaken for an adnexal mass. This fact should be borne in mind

  6. Ischiorectal abscess and ischiorectal-vaginal fistula as delayed complications of posterior intravaginal slingplasty: a case report.

    PubMed

    Chen, Heidi Wen-Chu; Guess, Marsha K; Connell, Kathleen A; Bercik, Richard S

    2009-10-01

    Synthetic meshes have been used extensively to augment surgical management of pelvic organ prolapses. Posterior intravaginal sling (IVS) is a technique used for correcting vaginal vault/apical prolapse, posterior vaginal prolapse or rectocele. There are limited data on long-term safety of this procedure. In a subanalysis of the IVS tapes from the SUSPEND trial performed secondary to the large number of patients with complications of suburethral sling erosions after IVS, it was noted that the sling erosion tended to have a delayed presentation secondary to poor incorporation of the mesh. A 48-year-old woman with cystocele, uterine prolapse and rectocele had undergone total vaginal hysterectomy, mesh-augmented anterior repair, posterior colporrhaphy and posterior intravaginal slingplasty (IVS) in July 2005. Thirty months after the surgery, she presented with gradual symptoms of copious vaginal discharge for several weeks followed by constant right buttock pain and swelling. Examination was notable for intact mesh with no signs of erosion and a 3-cm induration deep within the right buttock. Computed tomography suggested a pelvic abscess. Magnetic resonance imaging confirmed a right ischiorectal fossa abscess and a vaginal fistula. The patient underwent sling excision, right ischiorectal fossa exploration and vaginal fistula repair. A fistulous tract was found to extend along the intact sling from the vaginal epithelium toward the right ischiorectal fossa. At 2 months' followup, there were no recurrences or other complications. This is the first report of a delayed complication of an ischiorectal abscess associated with an ischiorectal-vaginal fistula that presented 30 months after the placement of a posterior IVS.

  7. Obturator externus abscess in a 9-year-old child: A case report and literature review.

    PubMed

    de Bodman, Charlotte; Ceroni, Dimitri; Dufour, Justine; Crisinel, Pierre-Alex; Bregou-Bourgeois, Aline; Zambelli, Pierre-Yves

    2017-03-01

    Obturator pyomyositis is a rare condition in children. Diagnosis is often delayed because of its rarity, and the vagaries of its presentation cause it to be easily be missed. Physicians should therefore familiarize themselves with this condition and consider it as a possible differential diagnosis in patients presenting with an acutely painful hip. Inflammatory syndrome is also frequent among sufferers and the MRI is a very sensitive diagnostic tool for obturator pyomyositis. Additionally, joint fluid aspirations and blood cultures are also useful in identifying the pathogen. The appropriate antibiotic therapy provides a rapid regression of symptoms during the early stage of pyomyositis. In cases of MRI-confirmed abscess, surgical treatment is indicated. Our report focuses on a case of obturator pyomyositis in a 9-year-old boy. The child was febrile for 5 days and could only manage to walk a few steps. His hip range of motion was restricted in all directions. In addition, the patient had presented pain and swelling of his right elbow for a day, with a restriction of motion in the joint. There was a clear inflammatory syndrome. A diagnosis of hip and elbow septic arthritis was suspected, and the child underwent joint aspiration of the both cited joints. The aspiration of the elbow returned pus. Conversely, no effusion was found in the hip aspiration. The administration of empiric intravenous antibiotherapy was started. An MRI revealed an osteomyelitis of the ischio-pubic area associated with a subperiosteal abscess. Subsequently, 3 days after elbow arthrotomy, a surgical treatment was performed on the patient's right hip in order to evacuate the subperiosteal abscess and muscular collection because of the persistence of the patient's symptoms and inflammatory syndrome despite susceptible intravenous antibiotics. Postsurgery the patient showed steady improvement. Such cases demonstrate how diagnosis can be difficult because pelvic pyomyositis is often mistaken for

  8. An In-Vitro Evaluation and Comparison of Apical Sealing Ability of Three Different Obturation Technique - Lateral Condensation, Obtura II, and Thermafil.

    PubMed

    Emmanuel, Samson; Shantaram, Kulkarni; Sushil, Kumar C; Manoj, Likhitkar

    2013-04-01

    Success of non-surgical root canal treatment is predicted by meticulous cleaning and shaping of the root canal system, three-dimensional obturation and a well-fitting "leakage-free" coronal restoration. The techniques of obturation that are available have their own relative position in the historical development of filling techniques. Over the years, pitfalls with one technique have often led to the development of newer methods of obturation, along with the recognition that no one method of obturation may satisfy all clinical cases. A total of 120 extracted human permanent anterior maxillary and mandibular single rooted teeth were selected for the present study and divided into 3 groups based on the method of obturation technique. Following the preparation the patency at the apical foramen was confirmed by passing a file #15. After obturation of all three groups, teeth were immersed in 1% of aqueous methylene blue dye for a period of two weeks and then samples were subjected to spectrophotometric analysis. The present study was conducted to evaluate in vitro the spectrophotometric analysis to quantitatively analyze relative amount of dye penetration using lateral condensation (Group I), Obtura II (Group II ), Thermafil obturating technique (Group III) with ZOE sealer used in all groups. Teeth obturated with lateral condensation (Group I) shows mean value of 0.0243 and standard deviation of 0.0056. The Group II thermoplasticized injectable moulded Guttapercha (Obtura II) showed 0.0239 mean and standard deviation value of 0.0045 and Group III Thermafil obturation technique shows 0.0189 as mean value and 0.0035 standard deviation values. Following conclusion was drawn from the present study. Group III i.e., Thermafil obturating technique shows minimum mean apical dye penetration compared to Group II (ObturaII) and Group I (lateral condensation).Lateral condensation shows maximum mean apical dye penetration in all three groups.There is no significant difference between

  9. Case Presentation of Two Maxillectomy Patients Restored with Two-piece Hollow Bulb Obturator Retained using Two Different Types of Magnets.

    PubMed

    Parameswari, B Devi; Rajakumar, M; Jagadesaan, N; Annapoorni, H

    2017-11-01

    Palatal defect can be repaired by reconstructive surgery and/or a dental prosthesis. We present prosthodontic rehabilitation of two partially edentulous patients, both with surgically induced palatal defect and explains how to achieve the goal for esthetics and phonetics. This also describes the fabrication of a hollow obturator by two piece method, which is simple and may be used as definitive obturator for maximum comfort of the patient. In both the above cases, since the mouth opening is restricted due to surgery, obturator prosthesis is given as two pieces retained with opposite poles of magnet, which facilitates the removal and insertion of the prosthesis.

  10. Pressure Roller For Tape-Lift Tests

    NASA Technical Reports Server (NTRS)

    Abrams, Eve

    1991-01-01

    Rolling device applies nearly constant, uniform pressure to surface. Simple tool exerts nearly constant pressure via compression of sheath by fixed amount. Pins hold wheels on cylinder and cylinder on tangs of handle. Cylinder and handle made of metal or plastic. Sheath press-fit or glued to cylinder. End pins attached to cylinder by adhesive or screw threads. Device intended for use in taking tape-lift samples of particulate contamination on surface.

  11. Taped Random Spectra for Reliability Demonstration Testing

    DTIC Science & Technology

    1981-04-01

    circuit , barrier strip terminals 9A and 9B. Closure of the normally-open contacts provides the gate current necessary to trigger the control TRIAC ... Circuit contains a TRIAC , DIAC, Reed Relay (R3) and the Tape Running Relay Driver. The Cam on/off switching is accomplished through the barrier strip...2-25 2I; Input Power Circuit .. .. .... ...... ...... ...... ........... 2-26 2-13 Typical Control Circuit

  12. Transaction aware tape-infrastructure monitoring

    NASA Astrophysics Data System (ADS)

    Nikolaidis, Fotios; Kruse, Daniele Francesco

    2014-06-01

    Administrating a large scale, multi protocol, hierarchical tape infrastructure like the CERN Advanced STORage manager (CASTOR)[2], which stores now 100 PB (with an increasing step of 25 PB per year), requires an adequate monitoring system for quick spotting of malfunctions, easier debugging and on demand report generation. The main challenges for such system are: to cope with CASTOR's log format diversity and its information scattered among several log files, the need for long term information archival, the strict reliability requirements and the group based GUI visualization. For this purpose, we have designed, developed and deployed a centralized system consisting of four independent layers: the Log Transfer layer for collecting log lines from all tape servers to a single aggregation server, the Data Mining layer for combining log data into transaction context, the Storage layer for archiving the resulting transactions and finally the Web UI layer for accessing the information. Having flexibility, extensibility and maintainability in mind, each layer is designed to work as a message broker for the next layer, providing a clean and generic interface while ensuring consistency, redundancy and ultimately fault tolerance. This system unifies information previously dispersed over several monitoring tools into a single user interface, using Splunk, which also allows us to provide information visualization based on access control lists (ACL). Since its deployment, it has been successfully used by CASTOR tape operators for quick overview of transactions, performance evaluation, malfunction detection and from managers for report generation.

  13. Software Computes Tape-Casting Parameters

    NASA Technical Reports Server (NTRS)

    deGroh, Henry C., III

    2003-01-01

    Tcast2 is a FORTRAN computer program that accelerates the setup of a process in which a slurry containing metal particles and a polymeric binder is cast, to a thickness regulated by a doctor blade, onto fibers wound on a rotating drum to make a green precursor of a metal-matrix/fiber composite tape. Before Tcast2, setup parameters were determined by trial and error in time-consuming multiple iterations of the process. In Tcast2, the fiber architecture in the final composite is expressed in terms of the lateral distance between fibers and the thickness-wise distance between fibers in adjacent plies. The lateral distance is controlled via the manner of winding. The interply spacing is controlled via the characteristics of the slurry and the doctor-blade height. When a new combination of fibers and slurry is first cast and dried to a green tape, the shrinkage from the wet to the green condition and a few other key parameters of the green tape are measured. These parameters are provided as input to Tcast2, which uses them to compute the doctor-blade height and fiber spacings needed to obtain the desired fiber architecture and fiber volume fraction in the final composite.

  14. STS-109 Mission Highlights Resource Tape

    NASA Astrophysics Data System (ADS)

    2002-05-01

    This video, Part 3 of 4, shows the activities of the STS-109 crew (Scott Altman, Commander; Duane Carey, Pilot; John Grunsfeld, Payload Commander; Nancy Currie, James Newman, Richard Linnehan, Michael Massimino, Mission Specialists) during flight days 6 and 7. The activities from other flight days can be seen on 'STS-109 Mission Highlights Resource Tape' Part 1 of 4 (internal ID 2002139471), 'STS-109 Mission Highlights Resource Tape' Part 2 of 4 (internal ID 2002137664), and 'STS-109 Mission Highlights Resource Tape' Part 4 of 4 (internal ID 2002137577). Flight day 6 features a very complicated EVA (extravehicular activity) to service the HST (Hubble Space Telescope). Astronauts Grunsfeld and Linnehan replace the HST's power control unit, disconnecting and reconnecting 36 tiny connectors. The procedure includes the HST's first ever power down. The cleanup of spilled water from the coollant system in Grunsfeld's suit is shown. The pistol grip tool, and two other space tools are also shown. On flight day 7, Newman and Massimino conduct an EVA. They replace the HST's FOC (Faint Object Camera) with the ACS (Advanced Camera for Surveys). The video ends with crew members playing in the shuttle's cabin with a model of the HST.

  15. Evaluation and Management of Vaginitis

    PubMed Central

    Carr, Phyllis L; Felsenstein, Donna; Friedman, Robert H

    1998-01-01

    OBJECTIVE To evaluate recent advances in our understanding of the clinical relevance, diagnosis, and treatment of vaginal infections, and to determine an efficient and effective method of evaluating this clinical problem in the outpatient setting. DATA SOURCES Relevant papers on vaginitis limited to the English language obtained through a MEDLINE search for the years 1985 to 1997 were reviewed. DATA SYNTHESIS Techniques that enable the identification of the various strains of candida have helped lead to a better understanding of the mechanisms of recurrent candida infection. From this information a rationale for the treatment of recurrent disease can be developed. Bacterial vaginosis has been associated with complications, including upper genital tract infection, preterm delivery, and wound infection. Women undergoing pelvic surgery, procedures in pregnancy, or pregnant women at risk of preterm delivery should be evaluated for bacterial vaginosis to decrease the rate of complications associated with this condition. New, more standardized criteria for the diagnosis of bacterial vaginosis may improve diagnostic consistency among clinicians and comparability of study results. Use of topical therapies in the treatment of bacterial vaginosis are effective and associated with fewer side effects than systemic medication. Trichomonas vaginalis, although decreasing in incidence, has been associated with upper genital tract infection. Therapy of T. vaginalis infection has been complicated by an increasing incidence of resistance to metronidazole. CONCLUSIONS Vaginitis is a common medical problem in women that is associated with significant morbidity and previously unrecognized complications. Research in recent years has improved diagnostic tools as well as treatment modalities for all forms of vaginitis. PMID:9613891

  16. Effects of a paraspinal-lumbar tape application during 7 days on the perceived area of tape contact.

    PubMed

    Funk, Stefan; Finke, Roy; Zeh, Stefan; Siebert, Tobias; Puta, Christian

    2017-05-01

    The study aimed to investigate the changes of the perceived area of tape contact during a lumbar tape application that lasted 7 days. Single group, repeated measures study. University research laboratory. Twenty-three healthy collegiate students in sports science. Perceived area of tape contact was collected by preparing a drawing of their individual perceived tape outline into a printed body image. Measurements were obtained immediately after fixation of the tape (day 0), at day 3 and day 7 during application and 5 min after the release of the application (day 7). There was no significant change of the perceived area of tape contact after 3 days of tape application. A significant decrease in the perceived area of tape contact was detected 7 days after application (p < 0.05) and after detaching the tape (p < 0.01) compared to the first measurement. Our results indicate that the perception of the area of tape contact of healthy sport students is decreased at 7 days. This effect could not be observed at 3 days. These results provide relevant information for the use of elastic tapes concerning the duration of application in medical therapy. Copyright © 2016 Elsevier Ltd. All rights reserved.

  17. Effect of Instrument Design and Access Outlines on the Removal of Root Canal Obturation Materials in Oval-shaped Canals.

    PubMed

    Niemi, Tuomas K; Marchesan, Melissa A; Lloyd, Adam; Seltzer, Robert J

    2016-10-01

    The aim of this study was to compare the effectiveness of TRUShape (TS) instruments with ProFile Vortex Blue (VB) instruments for the removal of obturation materials during retreatment of single-canal mandibular premolars performed through 2 access outlines. Initial root canal treatment was completed through a contracted endodontic cavity (CEC) design. Canals were instrumented to an F2 ProTaper instrument, obturated with warm lateral condensation of gutta-percha with AH Plus sealer, and allowed to set for 30 days at 37°C and 100% humidity. For retreatment, specimens were divided into 2 groups (n = 24) on the basis of access outline, CEC or traditional endodontic cavity (TEC). Retreatment was initiated by using ProTaper Retreatment instruments (D1-D3). Specimens were then stratified, further divided (n = 12), and reinstrumented up to TS 40 .06v or 40 .06 VB. Irrigation was performed by using 8.25% NaOCl and QMix 2in1. Retreatment time was recorded. Teeth were sectioned and photographed, and the percentage of remaining obturation materials was measured. Data were analyzed with Kruskal-Wallis analysis of variance for two-factor tests (α < 0.05). The interaction between access design and instrument type showed that the combination of CEC-VB presented significantly higher amounts of remaining obturation materials on the canal surface when compared with TEC-VB, CEC-TS, and TEC-TS (P ≤ .05). None of these other combinations were different from each other (P > .05). Significantly more time was required for retreatment with CEC-TS (27.68 ± 1.4 minutes) than the other groups (P < .05). Neither retreatment protocol was able to completely eliminate all obturation materials from the root canal surface of mandibular premolars. However, in the presence of a CEC access design, using TS instruments removed more obturating material in single-rooted, oval-shaped canals. Copyright © 2016 American Association of Endodontists. Published by Elsevier Inc. All rights

  18. Use of porcine vaginal tissue ex-vivo to model environmental effects on vaginal mucosa to toxic shock syndrome toxin-1

    SciTech Connect

    Davis, Catherine C.; Baccam, Mekhine; Mantz, Mary J.

    Menstrual toxic shock syndrome (mTSS) is a rare, recognizable, and treatable disease that has been associated with tampon use epidemiologically. It involves a confluence of microbial risk factors (Staphylococcus aureus strains that produce the superantigen—TSST-1), as well as environmental characteristics of the vaginal ecosystem during menstruation and host susceptibility factors. This paper describes a series of experiments using the well-characterized model of porcine vaginal mucosa ex-vivo to assess the effect of these factors associated with tampon use on the permeability of the mucosa. The flux of radiolabeled TSST-1 and tritiated water ({sup 3}H{sub 2}O) through porcine vaginal mucosa was determinedmore » at various temperatures, after mechanical disruption of the epithelial surface by tape stripping, after treatment with surfactants or other compounds, and in the presence of microbial virulence factors. Elevated temperatures (42, 47 and 52 °C) did not significantly increase flux of {sup 3}H{sub 2}O. Stripping of the epithelial layers significantly increased the flux of labeled toxin in a dose-dependent manner. Addition of benzalkonium chloride (0.1 and 0.5%) and glycerol (4%) significantly increased the flux of {sup 3}H{sub 2}O but sodium lauryl sulfate at any concentration tested did not. The flux of the labeled toxin was significantly increased in the presence of benzalkonium chloride but not Pluronic® L92 and Tween 20 and significantly increased with addition of α-hemolysin but not endotoxin. These results show that the permeability of porcine vagina ex-vivo to labeled toxin or water can be used to evaluate changes to the vaginal environment and modifications in tampon materials, and thus aid in risk assessment. - Highlights: • Model assessed local effects of tampon use on vaginal mucosa. • Risks were evaluated using two tracers to assess permeability in an ex vivo model. • Mechanical damage to the epithelial surface increased tracer

  19. Dinoprostone vaginal insert versus intravenous oxytocin to reduce postpartum blood loss following vaginal or cesarean delivery.

    PubMed

    Ozalp, E; Tanir, H M; Sener, T

    2010-01-01

    To compare the impact of a dinoprostone vaginal insert and intravenous oxytocin in reducing blood loss of women undergoing vaginal or cesarean delivery. This study was conducted among term singleton pregnancies delivered vaginally or by elective cesarean section. In the vaginally delivered cases, active management of the third stage of labor was conducted. During cesarean delivery, 20 IU of intravenous oxytocin was administered. Women, who either delivered via the vaginal or abdominal route, were then randomly allocated to receive 10 mg vaginal dinoprostone insert for 12 hours (group I, n: 100) or intravenous oxytocin (group II, n: 100), respectively. Mean blood loss and need for additional uterotonics and postpartum hemoglobin and hematocrit levels at 24 and 36 hours after delivery did not differ between the two groups. Women allocated to the dinoprostone vaginal insert arm experienced more nausea and vomiting. Dinoprostone vaginal insert was as effective as intravenous oxytocin in the prevention of postpartum blood loss.

  20. A prospective randomized blister prevention trial assessing paper tape in endurance distances (Pre-TAPED).

    PubMed

    Lipman, Grant S; Ellis, Mark A; Lewis, Erica J; Waite, Brandee L; Lissoway, John; Chan, Garrett K; Krabak, Brian J

    2014-12-01

    Friction foot blisters are a common injury occurring in up to 39% of marathoners, the most common injury in adventure racing, and represent more than 70% of medical visits in multi-stage ultramarathons. The goal of the study was to determine whether paper tape could prevent foot blisters in ultramarathon runners. This prospective randomized trial was undertaken during RacingThePlanet 155-mile (250-km), 7-day self-supported ultramarathons in China, Australia, Egypt, Chile, and Nepal in 2010 and 2011. Paper tape was applied prerace to one randomly selected foot, with the untreated foot acting as the own control. The study end point was development of a hot spot or blister on any location of either foot. One hundred thirty-six participants were enrolled with 90 (66%) having completed data for analysis. There were 36% women, with a mean age of 40 ± 9.4 years (range, 25-40 years) and pack weight of 11 ± 1.8 kg (range, 8-16 kg). All participants developed blisters, with 89% occurring by day 2 and 59% located on the toes. No protective effect was observed by the intervention (47 versus 35; 52% versus 39%; P = .22), with fewer blisters occurring around the tape on the experimental foot than under the tape (23 vs 31; 25.6% versus 34.4%), yet 84% of study participants when queried would choose paper tape for blister prevention in the future. Although paper tape was not found to be significantly protective against blisters, the intervention was well tolerated with high user satisfaction. Copyright © 2014 Wilderness Medical Society. Published by Elsevier Inc. All rights reserved.

  1. Vulvovaginitis and vaginal discharge in general practice

    PubMed Central

    Shannon, W.

    1975-01-01

    Ninety-four patients with vulvovaginitis and vaginal discharge were assessed clinically and had vaginal swabs taken in an effort to establish a definite diagnosis. A high incidence of fungous infection was found while there was a surprisingly low incidence of Trichomonal vaginitis. These findings vary markedly from recent surveys in other countries (Delaha et al. (1964); Gray and Barnes, 1965; Desai et al., 1966). PMID:1223281

  2. Vaginal delivery of breech presentation.

    PubMed

    Kotaska, Andrew; Menticoglou, Savas; Gagnon, Robert

    2009-06-01

    To review the physiology of breech birth; to discern the risks and benefits of a trial of labour versus planned Caesarean section; and to recommend to obstetricians, family physicians, midwives, obstetrical nurses, anaesthesiologists, pediatricians, and other health care providers selection criteria, intrapartum management parameters, and delivery techniques for a trial of vaginal breech birth. Trial of labour in an appropriate setting or delivery by pre-emptive Caesarean section for women with a singleton breech fetus at term. Reduced perinatal mortality, short-term neonatal morbidity, long-term infant morbidity, and short- and long-term maternal morbidity and mortality. Medline was searched for randomized trials, prospective cohort studies, and selected retrospective cohort studies comparing planned Caesarean section with a planned trial of labour; selected epidemiological studies comparing delivery by Caesarean section with vaginal breech delivery; and studies comparing long-term outcomes in breech infants born vaginally or by Caesarean section. Additional articles were identified through bibliography tracing up to June 1, 2008. The evidence collected was reviewed by the Maternal Fetal Medicine Committee of the Society of Obstetricians and Gynaecologists of Canada (SOGC) and quantified using the criteria and classifications of the Canadian Task Force on Preventive Health Care. This guideline was compared with the 2006 American College of Obstetrician's Committee Opinion on the mode of term singleton breech delivery and with the 2006 Royal College of Obstetrician and Gynaecologists Green Top Guideline: The Management of Breech Presentation. The document was reviewed by Canadian and International clinicians with particular expertise in breech vaginal delivery. The Society of Obstetricians and Gynaecologists of Canada. SUMMARY STATEMENTS: 1. Vaginal breech birth can be associated with a higher risk of perinatal mortality and short-term neonatal morbidity than

  3. Technique for recovery of voice data from heat damaged magnetic tape

    NASA Technical Reports Server (NTRS)

    Melugin, J. F.; Obrien, D. E., III (Inventor)

    1974-01-01

    A method for conditioning, and thus enabling retrieval of intelligence from, magnetic tapes after damage from heat has caused the tape to wrinkle and curl severely thereby reducing tape width to less than one-half its original size. The damaged tape is superposed on a first piece of splicing tape with the oxide side of the magnetic tape in contact with the adhesive side of the splicing tape and then carefully smoothed by a special tool. A second piece of splicing tape is placed on the backing side of the magnetic tape then the resulting tape stack is trimmed to the original width of the magnetic tape. After the first piece of splicing tape is carefully removed from the oxide side of the damaged magnetic tape, the resulting magnetic tape is then ready to be placed into a recorder for playback.

  4. Use of binaural beat tapes for treatment of anxiety: a pilot study of tape preference and outcomes.

    PubMed

    Le Scouarnec, R P; Poirier, R M; Owens, J E; Gauthier, J; Taylor, A G; Foresman, P A

    2001-01-01

    Recent studies and anecdotal reports suggest that binaural auditory beats can affect mood, performance on vigilance tasks, and anxiety. To determine whether mildly anxious people would report decreased anxiety after listening daily for 1 month to tapes imbedded with tones that create binaural beats, and whether they would show a definite tape preference among 3 tapes. A 1-group pre-posttest pilot study. Patients' homes. A volunteer sample of 15 mildly anxious patients seen in the Clinique Psyché, Montreal, Quebec. Participants were asked to listen at least 5 times weekly for 4 weeks to 1 or more of 3 music tapes containing tones that produce binaural beats in the electroencephalogram delta/theta frequency range. Participants also were asked to record tape usage, tape preference, and anxiety ratings in a journal before and after listening to the tape or tapes. Anxiety ratings before and after tape listening, pre- and post-study State-Trait Anxiety Inventory scores, and tape preferences documented in daily journals. Listening to the binaural beat tapes resulted in a significant reduction in the anxiety score reported daily in patients' diaries. The number of times participants listened to the tapes in 4 weeks ranged from 10 to 17 (an average of 1.4 to 2.4 times per week) for approximately 30 minutes per session. End-of-study tape preferences indicated that slightly more participants preferred tape B, with its pronounced and extended patterns of binaural beats, over tapes A and C. Changes in pre- and posttest listening State-Trait Anxiety Inventory scores trended toward a reduction of anxiety, but these differences were not statistically significant. Listening to binaural beat tapes in the delta/theta electroencephalogram range may be beneficial in reducing mild anxiety. Future studies should account for music preference among participants and include age as a factor in outcomes, incentives to foster tape listening, and a physiologic measure of anxiety reduction. A

  5. Obturator internus pyomyositis manifested as sciatica in a patient with subacute bacterial endocarditis: A rare case report.

    PubMed

    Hsu, Wei-Ching; Hsu, Jin-Yi; Chen, Michael Yu-Chih; Liang, Chung-Chao

    2016-07-01

    Pyomyositis is a pyogenic infection of the skeletal muscles causing myalgia and fever in patients. Hematogenous seeding engendered by persistent bacteremia and septic embolism is usually the underlying cause of the disease. Trauma, intravenous drug use, and immunodeficiency are the main predisposing factors.Obturator internus pyomyositis with sciatica has not previously been reported. We report a rare case of a patient with subacute bacterial endocarditis presenting with left buttock pain and sciatica.Computed tomography confirmed the diagnosis of obturator internus pyomyositis. The patient was discharged uneventfully after successful antibiotic treatment.The mortality rate of patients who have pyomyositis comorbid with another condition or disease is extremely high. Early diagnosis and aggressive management are imperative.

  6. STS-109 Mission Highlights Resource Tape

    NASA Astrophysics Data System (ADS)

    2002-05-01

    This video, Part 4 of 4, shows footage of crew activities from flight days 8 through 12 of STS-109. The crew included: Scott Altman, Commander; Duane Carey, Pilot; John Grunsfeld, Payload Commander; Nancy Currie, Richard Linnehan, James Newman, Michael Massimino, Mission Speicalists. The activities from other flights days can be seen on 'STS-109 Mission Highlights Resource Tape' Part 1 of 4 (internal ID 2002139471), 'STS-109 Mission Highlights Resource Tape' Part 2 of 4 (internal ID 2002137664), and 'STS-109 Mission Highlights Resource Tape' Part 3 of 4 (internal ID 2002139476). The primary activity on flight day 8 was an EVA (extravehicular activity) by Grunsfeld and Linnehan to install a cryocooler and radiator for the NICMOS (Near Infrared Camera and Multi-Object Spectrometer) on the HST (Hubble Space Telescope). Before returning to Columbia's airlock, the astronauts, with a cloudy background, hold onto the orbiter and offer their thoughts on the significance of their mission, the HST, and spaceflight. Footage from flight day 9 includes the grappling, unbearthing, and deployment of the HST from Columbia, and the crew coordinating and videotaping Columbia's departure. Flight day 10 was a relatively inactive day, and flight day 11 includes a checkout of Columbia's aerodynamic surfaces. Columbia landed on flight day 12, which is covered by footage of the crew members speaking during reentry, and their night landing, primarily shown through the orbiter's head-up display. The video includes numerous views of the HST, as well as views of the the Galapagos Islands, Madagascar, and Southern Africa with parts of the Atlantic, Indian, and Pacific Oceans, and part of the coast of Chile. The pistol grip space tool is shown in use, and the crew answers two messages from the public, including a message to Massimino from the Fire Department of New York.

  7. STS-109 Mission Highlights Resource Tape

    NASA Astrophysics Data System (ADS)

    2002-05-01

    This video, Part 2 of 4, shows the activities of the STS-109 crew (Scott Altman, Commander; Duane Carey, Pilot; John Grunsfeld, Payload Commander; Nancy Currie, James Newman, Richard Linnehan, Michael Massimino, Mission Specialists) during flight days 4 and 5. The activities from other flights days can be seen on 'STS-109 Mission Highlights Resource Tape' Part 1 of 4 (internal ID 2002139471), 'STS-109 Mission Highlights Resource Tape' Part 3 of 4 (internal ID 2002139476), and 'STS-109 Mission Highlights Resource Tape' Part 4 of 4 (internal ID 2002137577). The primary activities during these days were EVAs (extravehicular activities) to replace two solar arrays on the HST (Hubble Space Telescope). Footage from flight day 4 records an EVA by Grunsfeld and Linnehan, including their exit from Columbia's payload bay airlock, their stowing of the old HST starboard rigid array on the rigid array carrier in Columbia's payload bay, their attachment of the new array on HST, the installation of a new starboard diode box, and the unfolding of the new array. The pistol grip space tool used to fasten the old array in its new location is shown in use. The video also includes several shots of the HST with Earth in the background. On flight day 5 Newman and Massimino conduct an EVA to change the port side array and diode box on HST. This EVA is very similar to the one on flight day 4, and is covered similarly in the video. A hand operated ratchet is shown in use. In addition to a repeat of the previous tasks, the astronauts change HST's reaction wheel assembly, and because they are ahead of schedule, install installation and lubricate an instrument door on the telescope. The Earth views include a view of Egypt and Israel, with the Nile River, Red Sea, and Mediterranean Sea.

  8. STS-109 Mission Highlights Resource Tape

    NASA Astrophysics Data System (ADS)

    2002-05-01

    This video, Part 1 of 4, shows the activities of the STS-109 crew (Scott Altman, Commander; Duane Carey, Pilot; John Grunsfeld, Payload Commander; Nancy Currie, James Newman, Richard Linnehan, Michael Massimino, Mission Specialists) during flight days 1 through 3. The activities from other flight days can be seen on 'STS 109 Mission Highlights Resource Tape' Part 2 of 4 (internal ID 2002137664), 'STS 109 Mission Highlights Resource Tape' Part 3 of 4 (internal ID 2002139471), and 'STS-109 Mission Highlights Resource Tape' Part 4 of 4 (internal ID 2002137577). The main activity recorded during flight day 1 is the liftoff of Columbia. Attention is given to suit-up, boarding, and pre-flight procedures. The pre-launch crew meal has no sound. The crew members often wave to the camera before liftoff. The jettisoning of the solid rocket boosters is shown, and the External Tank is seen as it falls to Earth, moving over African dunes in the background. There are liftoff replays, including one from inside the cockpit. The opening of the payload bay doors is seen from the rear of the shuttle's cockpit. The footage from flight day 2 shows the Flight Support System for bearthing the HST (Hubble Space Telescope). Crew preparations for the bearthing are shown. Flight day 3 shows the tracking of and approach to the HST by Columbia, including orbital maneuvers, the capture of the HST, and its lowering onto the Flight Support System. Many views of the HST are shown, including one which reveals an ocean and cloud background as the HST retracts a solar array.

  9. Certification of ICI 1012 optical data storage tape

    NASA Technical Reports Server (NTRS)

    Howell, J. M.

    1993-01-01

    ICI has developed a unique and novel method of certifying a Terabyte optical tape. The tape quality is guaranteed as a statistical upper limit on the probability of uncorrectable errors. This is called the Corrected Byte Error Rate or CBER. We developed this probabilistic method because of two reasons why error rate cannot be measured directly. Firstly, written data is indelible, so one cannot employ write/read tests such as used for magnetic tape. Secondly, the anticipated error rates need impractically large samples to measure accurately. For example, a rate of 1E-12 implies only one byte in error per tape. The archivability of ICI 1012 Data Storage Tape in general is well characterized and understood. Nevertheless, customers expect performance guarantees to be supported by test results on individual tapes. In particular, they need assurance that data is retrievable after decades in archive. This paper describes the mathematical basis, measurement apparatus and applicability of the certification method.

  10. Comparative Evaluation of Sealing Ability of Three Newer Root Canal Obturating Materials Guttaflow, Resilon and Thermafil: An In Vitro Study

    PubMed Central

    H Bhandi, Shilpa; T S, Subhash

    2013-01-01

    Introduction: Microleakage continues to be a main reason for failure of root canal treatment where the challenge has been to achieve an adequate seal between the internal structure and the main obturating material. The objective of this study is to compare the sealing ability of 3 newer obturating materials GuttaFlow, Resilon/Epiphany system (RES) and Thermafil, using silver nitrate dye and observing under stereomicroscope. Methodology: Thirty single rooted teeth were divided into following groups. Group I : GuttaFlow ;Group II : Resilon /Epiphany sealer Group III : Thermafil with AH-Plus sealer. Teeth were decoronated and instrumented with profile rotary system and obturated with specified materials. Apical seal was determined by dye penetration method using silver nitrate. Then the specimens were transversely sectioned at each mm till 3 mm from the apex. Dye leakage was determined using stereomicroscope. Statistical analysis of the results was performed using Kruskall-Wallis test. Results: The results showed that Group II i.e., Resilon with Epiphany sealer showed the least amount of microleakage when compared to Group I i.e., GuttaFlow and Group III i.e., Thermafil with AH-plus sealer. Conclusion: Based on the results of this study it can be concluded that RES had higher sealing ability followed by Thermafil and GuttaFlow in vitro but further studies have to be carried out to make a direct correlation between these results and invivo situation. How to cite this article: Bhandi S H, Subhash T S. Comparative Evaluation of Sealing Ability of Three Newer Root Canal Obturating Materials Guttaflow, Resilon and Thermafil: An In Vitro Study. J Int Oral Health 2013; 5(1):54-65. PMID:24155579

  11. Effect of different root canal obturating materials on push-out bond strength of a fiber dowel.

    PubMed

    Aggarwal, Vivek; Singla, Mamta; Miglani, Sanjay; Kohli, Sarita

    2012-07-01

    During dowel space preparation, the instrumentation forms a thick smear layer along with sealer-occluded dentinal tubules. The purpose of this study was to evaluate the effect of different obturating materials on push-out bond strength of a fiber dowel. Fifty human uniradicular teeth were decoronated and prepared using the step-back technique. The specimens were divided into five groups on the basis of obturating materials: group I received no obturation; group II (ZOE) gutta-percha and zinc oxide eugenol sealer; group III (ZOAH) gutta-percha and AH plus sealer; group IV (GF) GuttaFlow; and group V (RE) with Resilon Epiphany system. Dowel spaces were made with manufacturer's provided drills, and a fiber dowel was luted. Horizontal slices were obtained from the middle third, and push-out bond strength (S) was evaluated. Statistical analysis was carried out using one-way ANOVA and post hoc Tukey's test. The push-out bond strength values in the control group, ZOE, ZOAH, GF, and RE were 9.303 ± 0.565 MPa, 8.859 ± 0.539 MPa, 8.356 ± 0.618 MPa, 9.635 ± 0.435 MPa, and 8.572 ± 0.256 MPa, respectively. There was no statistically significant difference between the S values of all the groups (p > 0.05). There was no effect of different tested obturating materials on the push-out bond strength of fiber dowels; however, further studies should be conducted. © 2012 by the American College of Prosthodontists.

  12. More frequent vaginal orgasm is associated with experiencing greater excitement from deep vaginal stimulation.

    PubMed

    Brody, Stuart; Klapilova, Katerina; Krejčová, Lucie

    2013-07-01

    Research indicated that: (i) vaginal orgasm (induced by penile-vaginal intercourse [PVI] without concurrent clitoral masturbation) consistency (vaginal orgasm consistency [VOC]; percentage of PVI occasions resulting in vaginal orgasm) is associated with mental attention to vaginal sensations during PVI, preference for a longer penis, and indices of psychological and physiological functioning, and (ii) clitoral, distal vaginal, and deep vaginal/cervical stimulation project via different peripheral nerves to different brain regions. The aim of this study is to examine the association of VOC with: (i) sexual arousability perceived from deep vaginal stimulation (compared with middle and shallow vaginal stimulation and clitoral stimulation), and (ii) whether vaginal stimulation was present during the woman's first masturbation. A sample of 75 Czech women (aged 18-36), provided details of recent VOC, site of genital stimulation during first masturbation, and their recent sexual arousability from the four genital sites. The association of VOC with: (i) sexual arousability perceived from the four genital sites and (ii) involvement of vaginal stimulation in first-ever masturbation. VOC was associated with greater sexual arousability from deep vaginal stimulation but not with sexual arousability from other genital sites. VOC was also associated with women's first masturbation incorporating (or being exclusively) vaginal stimulation. The findings suggest (i) stimulating the vagina during early life masturbation might indicate individual readiness for developing greater vaginal responsiveness, leading to adult greater VOC, and (ii) current sensitivity of deep vaginal and cervical regions is associated with VOC, which might be due to some combination of different neurophysiological projections of the deep regions and their greater responsiveness to penile stimulation. © 2013 International Society for Sexual Medicine.

  13. Star Catalogs on Punched Cards and Magnetic Tape

    NASA Technical Reports Server (NTRS)

    Berbert, J. H.

    1961-01-01

    In connection with the calibration of the Minitrack satellite tracking stations, the Goddard Space Flight Center has had the contents of a number of star catalogs put on punched cards and magnetic tape. This report discusses the plate data reduction procedures, briefly describes the information on the punched cards and magnetic tape, and calls attention to other applications of the card and tape star catalogs. The Goddard Space Flight Center has offered to prepare duplicate catalogs for qualified organizations.

  14. GSFC specification electronic data processing magnetic recording tape

    NASA Technical Reports Server (NTRS)

    Tinari, D. F.; Perry, J. L.

    1980-01-01

    The design requirements are given for magnetic oxide coated, electronic data processing tape, wound on reels. Magnetic recording tape types covered by this specification are intended for use on digital tape transports using the Non-Return-to-Zero-change-on-ones (NRZI) recording method for recording densities up to and including 800 characters per inch (cpi) and the Phase-Encoding (PE) recording method for a recording density of 1600 cpi.

  15. Faceted ceramic fibers, tapes or ribbons and epitaxial devices therefrom

    DOEpatents

    Goyal, Amit

    2013-07-09

    A crystalline article includes a single-crystal ceramic fiber, tape or ribbon. The fiber, tape or ribbon has at least one crystallographic facet along its length, which is generally at least one meter long. In the case of sapphire, the facets are R-plane, M-plane, C-plane or A-plane facets. Epitaxial articles, including superconducting articles, can be formed on the fiber, tape or ribbon.

  16. Faceted ceramic fibers, tapes or ribbons and epitaxial devices therefrom

    DOEpatents

    Goyal, Amit [Knoxville, TN

    2012-07-24

    A crystalline article includes a single-crystal ceramic fiber, tape or ribbon. The fiber, tape or ribbon has at least one crystallographic facet along its length, which is generally at least one meter long. In the case of sapphire, the facets are R-plane, M-plane, C-plane or A-plane facets. Epitaxial articles, including superconducting articles, can be formed on the fiber, tape or ribbon.

  17. Getting in Taped, Part I and Part II

    ERIC Educational Resources Information Center

    Cundy, H. M.; Higgins, J.

    1971-01-01

    This article is in two parts: discussion of mathematical concepts involved in converting the reading from the tape-recorder counter which counts the turns of the run-off spool to that from the counter which counts turns of the take-up spool; calculating the length of tape run off when given the reading from the tape-recorder counter of the run-off…

  18. Vaginal hysterectomy, an outpatient procedure.

    PubMed

    Engh, Marie Ellström; Hauso, Wenche

    2012-11-01

    To report our experience of treating women undergoing vaginal hysterectomy in an outpatient setting and to identify risk factors for hospital admission and women dissatisfied with care. Prospective observational report. department of obstetrics and gynecology, university hospital in Norway. 150 women who underwent vaginal hysterectomy at the outpatient clinic from February 2009 to April 2010. Perioperative data were collected prospectively and case notes were searched for complications. On the first postoperative day all women were contacted by telephone by a nurse. A visual analogue scale (VAS) was used to monitor pain and nausea during the stay at the outpatient clinic and the day after surgery. VAS was also used to specify the women's degree of satisfaction with care the day after surgery. The number of women who could be discharged from the outpatient unit and had a satisfaction score of ≥7 the day after surgery. Of the 150 women, 84% could be discharged after a mean observation period of 276 min (SD ± 80 min). The mean satisfaction score was 9.0, SD ± 1.4, and 92.6% of the women reported ≥7 points in the satisfaction score. No women with serious complications were sent home. Using a multivariable logistic regression model only pain at discharge was found as significant (p= 0.009) for admittance to hospital. Vaginal hysterectomy is a feasible outpatient procedure and the majority of women were satisfied with the care they received. © 2012 The Authors Acta Obstetricia et Gynecologica Scandinavica© 2012 Nordic Federation of Societies of Obstetrics and Gynecology.

  19. Three-dimensional finite element analysis of the application of attachment for obturator framework in unilateral maxillary defect.

    PubMed

    Sun, J; Jiao, T; Tie, Y; Wang, D-M

    2008-09-01

    The aim of this study was to evaluate the stress on the abutment teeth and framework ina unilateral maxillary defect which was restored by an obturator retained by resin-bonded extra coronal attachment. A three-dimensional finite element model of the human unilateral maxillary defect was constructed. Traditional obturator framework with four casting circumferential clasp was established (model 1). A continuous lingual guide plane of 0.5 mm thickness on all of the remaining teeth, with Mini-SG/F attachment on the mesial surface of the central incisor was also established (model 2). The modelling and analytical processes were performed using the ANSYS technologies. Stress was transmitted to the anterior part of the palate, with stress values being lower on the anterior teeth compared with the posteriors. The highest stress value of model 1 and model 2 was 13.1 Mpa, 19.9 Mpa respectively. Stress concentrations were found at the junction of the attachment to the lingual guide plane and the anterior part of the lingual plane. The results of this study suggest that the application of a resin-bonded extra coronal attachment for obturator retention is in accordance with the design principles for the restorative treatment of maxillary defects.The design of the attachment framework needs to be further investigated. Benefit can be gained by splinting the abutment teeth.

  20. Nerve block of articular branches of the obturator and femoral nerves for the treatment of hip joint pain.

    PubMed

    Yavuz, Ferdi; Yasar, Evren; Ali Taskaynatan, Mehmet; Goktepe, Ahmet Salim; Tan, Arif Kenan

    2013-01-01

    The aim of this retrospective study was to investigate the effectiveness of the nerve block of articular branches of obturator and femoral nerves in patients with intractable pain due to hip osteoarthritis. Twenty patients (8 female and 12 male; with a mean age 53.5 years) were retrospectively identified who had received nerve block of articular branches of obturator and femoral nerves for chronic hip joint pain due to hip osteoarthritis. The outcome measures (visual analogue pain scale, the level of patient satisfaction with nerve block, reduction rate of NSAID using) were assessed before the treatment and at the 1st and 3rd months after injection. Mean reduction in hip joint pain while walking and at night between the baseline and 1st month, and between the baseline and 3rd month were statistically significant (p< 0.05). At the 1st and 3rd months after treatment, the reduction rates of NSAID using were almost 67% and 71%; respectively. At the 1st and 3rd months after treatment, the level of patient satisfaction with nerve block were 73.00 ± 21.23 mm and 73.50 ± 18.14 mm; respectively. We found that nerve blocks of articular branches of obturator and femoral nerves were effective in short- and mid-term for reducing chronic hip joint pain.

  1. Penetrating Obturator Artery Injury after Gunshot Wounds: A Successful Multidisciplinary Trauma Team Approach to a Potentially Lethal Injury.

    PubMed

    Maraqa, Tareq I; Shin, Ji-Sun J; Diallo, Ismael; Sachwani-Daswani, Gul R; Mercer, Leo C

    2017-11-17

    Obturator artery injury (OAI) from pelvic gunshot wounds (GSW) is a rarely reported condition. Hemorrhages from pelvic trauma (PT) are mostly venous. Arterial hemorrhages represent about 10-20% of PTs. When arterial hemorrhages from PT occur, they are a severe and deadly complication often causing significant hemodynamic instability and eventual shock. A  23-year-old male presented to our emergency service via a private vehicle with multiple gunshot wounds to both thighs and to the lower back, resulted in rectal and obturator artery (OA) injuries. The patient underwent a successful coil-embolization of the right OA. Given the density of structures within the pelvis, patients who sustain gunshot wounds to the pelvic region are at high risk for injury to the small bowel, sigmoid colon, rectum, bladder, and/or vascular structures. While bleeding is the major cause of early mortality in PT, rectal injuries carry the highest mortality due to visceral injuries. A high clinical index of suspicion is needed to diagnose an iliac artery injury or injury to its branches. Prompt computed tomographic angiogram (CTA) and embolization of the OA is the best method to control and stop the bleeding and improve the mortality outcome. Clinicians caring for patients presenting with pelvic gunshot wounds should pay attention to the delayed presentation of internal hemorrhage from the OAs. A multidisciplinary team approach is crucial in the successful management of penetrating injuries to the obturator artery.

  2. Prosthetic reconstruction with an obturator using swing-lock attachment for a patient underwent maxillectomy: A clinical report

    PubMed Central

    2016-01-01

    Patients who underwent resection of maxilla due to benign or malignant tumor, or accident will have defect in palatal area. They get retention, support and stability from remaining tissues which are hardly optimal. The advantage of swing-lock attachment design is having multiple contacts on labial and lingual side of the abutment teeth by retentive strut and palatal bracing component. Because the force is distributed equally to abutment teeth, abutment teeth of poor prognosis can be benefited from it. It is also more advantageous to cover soft tissue defects which are hard to reach with conventional prosthesis. A 56-year-old female patient who had undergone a maxillectomy due to malignant melanoma complaining of loose and unstable surgical obturator. Surveyed crowns were placed on #12, 26, and 27. Teeth #11, 21, 22, and 23 had lingual rest seat and #24 had mesial rest seat to improve stability and support of the obturator. This clinical report presents the prosthetic management of a patient treated with obturator on the maxilla using swing-lock attachment to the remaining teeth. PMID:27826392

  3. Biomechanical 3-Dimensional Finite Element Analysis of Obturator Protheses Retained with Zygomatic and Dental Implants in Maxillary Defects

    PubMed Central

    Akay, Canan; Yaluğ, Suat

    2015-01-01

    Background The objective of this study was to investigate the stress distribution in the bone around zygomatic and dental implants for 3 different implant-retained obturator prostheses designs in a Aramany class IV maxillary defect using 3-dimensional finite element analysis (FEA). Material\\Methods A 3-dimensional finite element model of an Aramany class IV defect was created. Three different implant-retained obturator prostheses were modeled: model 1 with 1 zygomatic implant and 1 dental implant, model 2 with 1 zygomatic implant and 2 dental implants, and model 3 with 2 zygomatic implants. Locator attachments were used as a superstructure. A 150-N load was applied 3 different ways. Qualitative analysis was based on the scale of maximum principal stress; values obtained through quantitative analysis are expressed in MPa. Results In all loading conditions, model 3 (when compared models 1 and 2) showed the lowest maximum principal stress value. Model 3 is the most appropirate reconstruction in Aramany class IV maxillary defects. Two zygomatic implants can reduce the stresses in model 3. The distribution of stresses on prostheses were more rational with the help of zygoma implants, which can distribute the stresses on each part of the maxilla. Conclusions Aramany class IV obturator prosthesis placement of 2 zygomatic implants in each side of the maxilla is more advantageous than placement of dental implants. In the non-defective side, increasing the number of dental implants is not as suitable as zygomatic implants. PMID:25714086

  4. Supracervical hysterectomy - the vaginal route.

    PubMed

    Wilczyński, Miłosz; Cieślak, Jarosław; Malinowski, Andrzej

    2014-06-01

    Removal of the cervix during hysterectomy is not mandatory. There has been no irrefutable evidence so far that total hysterectomy is more beneficial to patients in terms of pelvic organ function. The procedure that leaves the cervix intact is called a subtotal hysterectomy. Traditional approaches to this surgery include laparoscopic and abdominal routes. Vaginal total hysterectomy has been proven to present many advantages over the other approaches. Therefore, it seems that this route should also be applied in the case of subtotal hysterectomy. We present 9 cases of patients who underwent subtotal hysterectomy performed through the vagina for benign gynecological diseases.

  5. Tape-cast sensors and method of making

    DOEpatents

    Mukundan, Rangachary [Santa Fe, NM; Brosha, Eric L [Los Alamos, NM; Garzon, Fernando H [Santa Fe, NM

    2009-08-18

    A method of making electrochemical sensors in which an electrolyte material is cast into a tape. Prefabricated electrodes are then partially embedded between two wet layers of the electrolyte tape to form a green sensor, and the green sensor is then heated to sinter the electrolyte tape around the electrodes. The resulting sensors can be used in applications such as, but not limited to, combustion control, environmental monitoring, and explosive detection. A electrochemical sensor formed by the tape-casting method is also disclosed.

  6. Specification for wide channel bandwidth one-inch video tape

    NASA Technical Reports Server (NTRS)

    Perry, Jimmy L.

    1988-01-01

    Standards and controls are established for the procurement of wide channel bandwidth one inch video magnetic recording tapes for Very Long Base Interferometer (VLBI) system applications. The Magnetic Tape Certification Facility (MTCF) currently maintains three specifications for the Quality Products List (QPL) and acceptance testing of magnetic tapes. NASA-TM-79724 is used for the QPL and acceptance testing of new analog tapes; NASA-TM-80599 is used for QPL and acceptance testing of new digital tapes; and NASA-TM-100702 is used for the QPL and acceptance testing of new IBM/IBM compatible 3480 magnetic tape cartridges. This specification will be used for the QPL and acceptance testing of new wide channel bandwidth one inch video magnetic recording tapes. The one inch video tapes used by the Jet Propulsion Lab., the Deep Space Network and the Haystack Observatory will be covered by this specification. These NASA stations will use the video tapes for their VLBI system applications. The VLBI system is used for the tracking of quasars and the support of interplanetary exploration.

  7. Reel-to-reel substrate tape polishing system

    DOEpatents

    Selvamanickam, Venkat; Gardner, Michael T.; Judd, Raymond D.; Weloth, Martin; Qiao, Yunfei

    2005-06-21

    Disclosed is a reel-to-reel single-pass mechanical polishing system (100) suitable for polishing long lengths of metal substrate tape (124) used in the manufacture of high-temperature superconductor (HTS) coated tape, including multiple instantiations of a polishing station (114) in combination with a subsequent rinsing station (116) arranged along the axis of the metal substrate tape (124) that is translating between a payout spool (110a) and a take-up spool (110b). The metal substrate tape obtains a surface smoothness that is suitable for the subsequent deposition of a buffer layer.

  8. Use of porcine vaginal tissue ex-vivo to model environmental effects on vaginal mucosa to toxic shock syndrome toxin-1.

    PubMed

    Davis, Catherine C; Baccam, Mekhine; Mantz, Mary J; Osborn, Thomas W; Hill, Donna R; Squier, Christopher A

    2014-01-15

    Menstrual toxic shock syndrome (mTSS) is a rare, recognizable, and treatable disease that has been associated with tampon use epidemiologically. It involves a confluence of microbial risk factors (Staphylococcus aureus strains that produce the superantigen-TSST-1), as well as environmental characteristics of the vaginal ecosystem during menstruation and host susceptibility factors. This paper describes a series of experiments using the well-characterized model of porcine vaginal mucosa ex-vivo to assess the effect of these factors associated with tampon use on the permeability of the mucosa. The flux of radiolabeled TSST-1 and tritiated water ((3)H2O) through porcine vaginal mucosa was determined at various temperatures, after mechanical disruption of the epithelial surface by tape stripping, after treatment with surfactants or other compounds, and in the presence of microbial virulence factors. Elevated temperatures (42, 47 and 52°C) did not significantly increase flux of (3)H2O. Stripping of the epithelial layers significantly increased the flux of labeled toxin in a dose-dependent manner. Addition of benzalkonium chloride (0.1 and 0.5%) and glycerol (4%) significantly increased the flux of (3)H2O but sodium lauryl sulfate at any concentration tested did not. The flux of the labeled toxin was significantly increased in the presence of benzalkonium chloride but not Pluronic® L92 and Tween 20 and significantly increased with addition of α-hemolysin but not endotoxin. These results show that the permeability of porcine vagina ex-vivo to labeled toxin or water can be used to evaluate changes to the vaginal environment and modifications in tampon materials, and thus aid in risk assessment. Copyright © 2013 Elsevier Inc. All rights reserved.

  9. Treatment of postmenopausal vaginal atrophy with 10-μg estradiol vaginal tablets.

    PubMed

    Panay, Nick; Maamari, Ricardo

    2012-03-01

    Postmenopausal estrogen deficiency can lead to symptoms of urogenital atrophy. Individuals with urogenital atrophy have symptoms that include vaginal dryness, vaginal and vulval irritation, vaginal soreness, pain and burning during urination (dysuria), increased vaginal discharge, vaginal odour, vaginal infections, recurrent urinary tract infections, pain associated with sexual activity (dyspareunia) and vaginal bleeding associated with sexual activity. Despite the frequency and effects of vaginal atrophy symptoms, they are often under-reported and, consequently, under-treated. Therefore, care of a menopausal woman should include a physical assessment of vaginal atrophy and a dialogue between the physician and the patient that explores existing symptoms and their effect on vulvovaginal health, sexuality and quality-of-life issues. The development of the ultra-low-dose 10-µg estradiol vaginal tablets is in line with the requirements of regulatory agencies and women's health societies regarding the use of the lowest effective hormonal dose. Because of its effectiveness and safety profiles, in addition to its minimal systemic absorption, the 10-µg estradiol vaginal tablet can offer greater reassurance to health-care providers and postmenopausal women with an annual estradiol administration of only 1.14 mg.

  10. 21 CFR 884.3900 - Vaginal stent.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Vaginal stent. 884.3900 Section 884.3900 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES... stent. (a) Identification. A vaginal stent is a device used to enlarge the vagina by stretching, or to...

  11. VBAC (Vaginal Birth After C-Section)

    MedlinePlus

    Vaginal birth after C-section (VBAC) Overview If you've delivered a baby by C-section and you're pregnant again, you might be able to choose between scheduling a repeat C-section or attempting vaginal birth after C-section ( ...

  12. Comparison of three mid-urethral tension-free tapes (TVT, TVT-O, and TVT-Secur) in the treatment of female stress urinary incontinence: 1-year follow-up.

    PubMed

    Wang, Yi-jun; Li, Fei-ping; Wang, Qian; Yang, Sen; Cai, Xian-guo; Chen, Ying-he

    2011-11-01

    The purpose of the study was to evaluate and compare the clinical values of tension-free vaginal tape (TVT), tension-free vaginal tape-transobturator (TVT-O), or tension-free vaginal tape-Secur (TVT-Secur) as treatment for female stress urinary incontinence. The pre-operative and 1-year post-operative follow-up protocols for patients who were treated with serial mid-urethral tension-free tape procedures in two hospitals from October 2008 to December 2009 were prospectively studied. These patients were randomly allocated to TVT, TVT-O, or TVT-Secur. A total of 102 women participated. At the 1-year follow-up, complications were not statistically different across the three groups except for pain in the thigh, which was more common in the TVT-O group. The overall efficacy and cure rate were similar between the TVT and TVT-O groups, but were significantly lower in the TVT-Secur group. A comparison of the three procedures shows that TVT-O is easy to operate and is as safe as TVT-Secur, and it has similar long-term efficacy to TVT, though, as one of the third-generation mid-urethral tension-free tapes, TVT-Secur is still being evaluated. Basing on the outcome of our study, it had rare complications but unsatisfactory efficacy, and we suggest that TVT-Secur is not fit for severe cases. However, observation and comparison of these groups in a larger sample size on a longer term are needed.

  13. Value of bacterial culture of vaginal swabs in diagnosis of vaginal infections.

    PubMed

    Nenadić, Dane; Pavlović, Miloš D

    2015-06-01

    Vaginal and cervical swab culture is still very common procedure in our country's everyday practice whereas simple and rapid diagnostic methods have been very rarely used. The aim of this study was to show that the employment of simple and rapid diagnostic tools [vaginal fluid wet mount microscopy (VFWMM), vaginal pH and potassium hydroxide (KOH) test] offers better assessment of vaginal environment than standard microbiologic culture commonly used in Serbia. This prospective study included 505 asymptomatic pregnant women undergoing VFWMM, test with 10% KOH, determination of vaginal pH and standard culture of cervicovaginal swabs. Combining findings from the procedures was used to make diagnoses of bacterial vaginosis (BV) and vaginitis. In addition, the number of polymorphonuclear leukocytes (PMN) was determined in each sample and analyzed along with other findings. Infections with Candida albicans and Trichomonas vaginalis were confirmed or excluded by microscopic examination. In 36 (6%) patients cervicovaginal swab cultures retrieved several aerobes and facultative anaerobes, whereas in 52 (11%) women Candida albicans was isolated. Based on VFWMM findings and clinical criteria 96 (19%) women had BV, 19 (4%) vaginitis, and 72 (14%) candidiasis. Of 115 women with BV and vaginitis, pH 4.5 was found in 5, and of 390 with normal findings 83 (21%) had vaginal pH 4.5. Elevated numbers of PMN were found in 154 (30%) women--in 83 (54%) of them VFWMM was normal. Specificity and sensitivity of KOH test and vaginal pH determination in defining pathological vaginal flora were 95% and 81%, and 79% and 91%, respectively. Cervicovaginal swab culture is expensive but almost non-informative test in clinical practice. The use of simpler and rapid methods as vaginal fluid wet mount microscopy, KOH test and vaginal pH offers better results in diagnosis, and probably in the treatment and prevention of sequels of vaginal infections.

  14. Vaginitis

    MedlinePlus

    ... a change in the balance of bacteria or yeast that are normally found in your vagina. There ... with a new partner Having many sexual partners Yeast infections (candidiasis) happen when too much candida grows ...

  15. Failure and fatigue characteristics of adhesive athletic tape.

    PubMed

    Bragg, Richard W; Macmahon, John M; Overom, Erin K; Yerby, Scott A; Matheson, Gordon O; Carter, Dennis R; Andriacchi, Thomas P

    2002-03-01

    Athletic tape has been commonly reported to lose much of its structural support after 20 min of exercise. Although many studies have addressed the functional performance characteristics of athletic tape, its mechanical properties are poorly understood. This study examines the failure and fatigue properties of several commonly used athletic tapes. A Web-based survey of professional sports trainers was used to select the following three tapes for the study: Zonas (Johnson & Johnson), Leukotape (Beiersdorf), and Jaylastic (Jaybird & Mais). Using a hydraulic material testing system (MTS), eight samples of each tape were compared in three different mechanical tests: load-to-failure, fatigue testing under load control, and fatigue testing under displacement control. Differences in tape microstructure were used to interpret the results of the mechanical tests. Significant differences (P < 0.001) in failure load, elongation at failure, and stiffness were found from failure tests. Significant differences were also found (P < 0.001) in fatigue behavior under both modes of control. As a representative example, in one normalized displacement control fatigue test after 20 min of cycling, 21% (Zonas), 29% (Leukotape), and 57% (Jaylastic) of the mechanical support was lost. After cycling, all tapes loaded to failure showed increased stiffness (P < 0.001), indicating significant energy absorption during cycling. Observed differences in the tapes' microstructure were qualitatively consistent with the measured differences in their mechanical properties. In understanding the shortcomings of currently available tapes, the results of these tests can now be used as benchmarks with which to compare and develop future tape designs. Ultimately, these improved tapes should reduce ankle injuries among athletes.

  16. The obturator oblique and iliac oblique/outlet views predict most accurately the adequate position of an anterior column acetabular screw.

    PubMed

    Guimarães, João Antonio Matheus; Martin, Murphy P; da Silva, Flávio Ribeiro; Duarte, Maria Eugenia Leite; Cavalcanti, Amanda Dos Santos; Machado, Jamila Alessandra Perini; Mauffrey, Cyril; Rojas, David

    2018-06-08

    Percutaneous fixation of the acetabulum is a treatment option for select acetabular fractures. Intra-operative fluoroscopy is required, and despite various described imaging strategies, it is debatable as to which combination of fluoroscopic views provides the most accurate and reliable assessment of screw position. Using five synthetic pelvic models, an experimental setup was created in which the anterior acetabular columns were instrumented with screws in five distinct trajectories. Five fluoroscopic images were obtained of each model (Pelvic Inlet, Obturator Oblique, Iliac Oblique, Obturator Oblique/Outlet, and Iliac Oblique/Outlet). The images were presented to 32 pelvic and acetabular orthopaedic surgeons, who were asked to draw two conclusions regarding screw position: (1) whether the screw was intra-articular and (2) whether the screw was intraosseous in its distal course through the bony corridor. In the assessment of screw position relative to the hip joint, accuracy of surgeon's response ranged from 52% (iliac oblique/outlet) to 88% (obturator oblique), with surgeon confidence in the interpretation ranging from 60% (pelvic inlet) to 93% (obturator oblique) (P < 0.0001). In the assessment of intraosseous position of the screw, accuracy of surgeon's response ranged from 40% (obturator oblique/outlet) to 79% (iliac oblique/outlet), with surgeon confidence in the interpretation ranging from 66% (iliac oblique) to 88% (pelvic inlet) (P < 0.0001). The obturator oblique and obturator oblique/outlet views afforded the most accurate and reliable assessment of penetration into the hip joint, and intraosseous position of the screw was most accurately assessed with pelvic inlet and iliac oblique/outlet views. Clinical Question.

  17. Obturator internus muscle autotransfer: a new concept for the treatment of anismus. Clinical experience.

    PubMed

    Farag, A

    1997-01-01

    In this study 20 patients suffering from chronic constipation due to spastic anal sphincters were operated upon using a new surgical technique. The technique aimed at constructing an active anal dilator mechanism using the obturator internus muscles mobilized from both sides and sutured to the side wall of the anal canal in order to overcome the spastic anal sphincters during defaecation. This series included 3 failures (15%), 16 successful cases (80%), and 1 dissatisfied patient despite normal postoperative investigations (5%). Eleven patients (55%) showed immediate postoperative normalization of their defaecation. Five patients (25%) showed normalization of their defaecation after 10 sessions of electric stimulation of the transposed muscles given 1 month postoperatively for 10 successive days. All the successful cases (16 patients) maintained their good results during the period of follow-up which ranged from 16 to 45 months (average = 30.31 months). For the successful cases, follow-up was from 16 to 42 months (average = 26.72 months). Immediate postoperative complications included 3 cases of wound infection and 2 cases of transient incontinence to gases which responded completely to postoperative Faradic stimulation. No cases of persistent incontinence of any degree were detected among the 20 patients studied. The 3 failures were mainly due to avoidable technical problems. The technique was safe, easy, and physiological, using a strictly perineal approach.

  18. Root canal obturation: experimental study on the thermafil system related to different irrigation protocols

    PubMed Central

    Migliau, Guido; Sofan, Afrah Ali Abdullah; Sofan, Eshrak Ali Abdullah; Cosma, Salvatore; Eramo, Stefano; Gallottini, Livio

    2014-01-01

    Summary Aim The aim of this study was to stress the ability of a specific obturation technique (thermafil technique) to seal root canal system in presence or absence of smear layer. Methodology Sixteen monoradicular teeth, extracted for periodontal reasons, were collected for this study. All specimens were prepared with nickel-titanium rotary files, and then divided into two groups: for each group was applied a different kind of irrigation method, verifying the effectiveness in removing the smear layer, thus rendering the dentinal tubules more permeable for penetration of softened gutta-percha. Thermafil system was used to fill the root canals, and then all the specimens were observed under scanning electron microscope (SEM). Results The results showed that the Group which followed irrigation only with sodium hypochlorite exhibited significantly less gutta-percha tags when compared to the second Group, which was irrigated with sodium hypochlorite and EDTA. Conclusion The thermafil systems have a very good quality of compression and fluency that permit to gain a good seal of endodontic space; furthermore it allows the penetration of gutta-percha with the formation of numerous of gutta-percha tags inside the dentinal tubules above all when smear layer is reduced or eliminated. PMID:25506413

  19. A novel digital workflow to manufacture personalized three-dimensional-printed hollow surgical obturators after maxillectomy.

    PubMed

    Kortes, J; Dehnad, H; Kotte, A N T; Fennis, W M M; Rosenberg, A J W P

    2018-04-07

    Partial or complete resection of the maxilla during tumour surgery causes oronasal defects, leading to oral-maxillofacial dysfunction, for which the surgical obturator (SO) is an important treatment option. Traditional manufacturing of SOs is complex, time-consuming, and often results in inadequate fit and function. This technical note describes a novel digital workflow to design and manufacture a three-dimensional (3D)-printed hollow SO. Registered computed tomography and magnetic resonance imaging images are used for gross tumour delineation. The produced RTStruct set is exported as a stereolitography (STL) file and merged with a 3D model of the dental status. Based on these merged files, a personalized and hollow digital SO design is created, and 3D printed. Due to the proper fit of the prefabricated SO, a soft silicone lining material can be used during surgery to adapt the prosthesis to the oronasal defect, instead of putty materials that are not suitable for this purpose. An STL file of this final SO is created during surgery, based on a scan of the relined SO. The digital workflow results in a SO weight reduction, an increased fit, an up-to-date digital SO copy, and overall easier clinical handling. Copyright © 2018 International Association of Oral and Maxillofacial Surgeons. Published by Elsevier Ltd. All rights reserved.

  20. Implant-Retained Obturator for an Edentulous Patient with a Hemimaxillectomy Defect Complicated with Microstomia

    PubMed Central

    2016-01-01

    Patient. A 68-year-old man was operated on for squamous cell carcinoma (T3N3M0) of the maxilla creating the hemimaxillary surgical defect on right side. The remaining arch was completely edentulous. There was remarkable limitation in the oral opening with reduced perimeter of the oral cavity due to radiation and surgical scar contracture. This article describes prosthetic rehabilitation by modifying the design of the obturator and achieving the retention with dental implant. Discussion. Severe limitation in the oral opening may occur in clinical situations following the postsurgical management of oral and maxillofacial defects. The prosthetic rehabilitation of the surgical defect in such patients becomes a challenging task due to limited access to the oral cavity. This challenge becomes even more difficult if the patient is edentulous and there are no teeth to gain the retention, stability, and support. Conclusion. In severe microstomia prosthesis insertion and removal can be achieved with modification of the maximum width of the prosthesis. Dental implant retention is useful treatment option in edentulous patients with maxillary surgical defect provided that sufficient bone volume and accessibility are there for implant placement. PMID:27843652

  1. A 16-channel cassette tape recorder system for clinical EEGs.

    PubMed

    Barlow, J S

    1975-02-01

    A 16-channel EEG tape recorder system having a frequency response of DC-100 Hz for each channel is described. The system utilized standard commercially available highfidelity audio tape decks in conjunction with specially designed circuits for time-division multiplexing a balanced amplitude modulation

  2. A Meta-Analysis of the Taped Problems Intervention

    ERIC Educational Resources Information Center

    Kleinert, Whitney L.; Codding, Robin S.; Minami, Takuya; Gould, Kaitlin

    2018-01-01

    Taped problems is an intervention strategy for addressing mathematics fluency that has been evaluated in multiple single-case design studies. Although its efficacy has been supported in individual studies, no comprehensive quantitative synthesis has been conducted on taped problems. The purpose of this study was to synthesize the literature that…

  3. JPL Ephemeris Tapes E9510, E9511, and E9512

    NASA Technical Reports Server (NTRS)

    Peabody, P. R.; Scott, J. F.; Orozco, E. G.

    1964-01-01

    The first issue of JPL Ephemeris Tapes is described. These tapes carry the positions and velocities of the planets and of the Moon, plus nutations and nutation rates in longitude and obliquity, together with second and fourth modified differences, for the interval December 30, 1949, to January 5, 2000.

  4. OCLC-MARC Tape Processing: A Functional Analysis.

    ERIC Educational Resources Information Center

    Miller, Bruce Cummings

    1984-01-01

    Analyzes structure of, and data in, the OCLC-MARC record in the form delivered via OCLC's Tape Subscription Service, and outlines important processing functions involved: "unreadable tapes," duplicate records and deduping, match processing, choice processing, locations processing, "automatic" and "input" stamps,…

  5. Surreptitious Taping: The Arguments for and the Ethics against.

    ERIC Educational Resources Information Center

    Cooper, Thomas W.

    Much discussion within media ethics has focused on the acceptability of surreptitious tape recording of news sources by media professionals. The most common legal and social arguments supporting secret taping assert that recorders "hear" and "remember" better, are expedient and practical, protect against libel suits, provide…

  6. Recovery of recordings from heat damaged magnetic tapes

    NASA Technical Reports Server (NTRS)

    Melugin, J. F.; Obrien, D. E., III

    1973-01-01

    Damaged tapes can now be repaired at home as long as damage does not extend to layer-to-layer adhesion within tape roll. Splice repaired section into good roll or cassette for copying. Every effort should be made to complete copying on first run, because fidelity in repaired section deteriorates with each repetition.

  7. Cassette Tape Catalog: 1980/1981 Unabridged Supplement.

    ERIC Educational Resources Information Center

    American Child Care Services, Hampton, VA.

    This unabridged supplement to the Child Care Information Center's tape cassette catalog contains a listing of all recordings made in calendar years 1980 and 1981. This document plus "The Revised 1976 Cassette Tape Catalog,""The 1977 Addendum," and "The 1978/1979 Unabridged Supplement" together provide a complete listing of the 1,776 tape…

  8. Amine content of vaginal fluid from untreated and treated patients with nonspecific vaginitis.

    PubMed Central

    Chen, K C; Forsyth, P S; Buchanan, T M; Holmes, K K

    1979-01-01

    We examined the vaginal washings from patients with nonspecific vaginitis (NSV) to seek biochemical markers and possible explanations for the signs and symptoms of this syndrome. Seven amines were identified including methylamine, isobutylamine, putrescine, cadaverine, histamine, tyramine, and phenethylamine. These amines may contribute to the symptoms of NSV and may contribute to the elevated pH of the vaginal discharge. They may also be partly responsible for the "fishy" odor that is characteristic of vaginal discharges from these patients. Among the seven amines, putrescine and cadaverine were the most abundant and were present in all vaginal discharges from each of ten patients before treatment. These amines are produced in vitro during growth of mixed vaginal bacteria in chemically defined medium, presumably by decarboxylation of the corresponding amino acids. We hypothesize the anaerobic vaginal organisms, previously shown to be quantitatively increased in NSV, are responsible for the amine production, because metronidazole inhibited the production of amines by vaginal bacteria in vitro, and Haemophilus vaginalis did not produce amines. H. vaginalis did release high concentrations of pyruvic acid and of amino acids during growth in peptone-starch-dextrose medium, whereas, other vaginal flora consumed both pyruvic acid and amino acids in the same medium during growth. These findings suggest that a symbiotic relationship may exist between H. vaginalis and other vaginal flora in patients with NSV. Images PMID:447831

  9. Protection against rat vaginal candidiasis by adoptive transfer of vaginal B lymphocytes.

    PubMed

    De Bernardis, Flavia; Santoni, Giorgio; Boccanera, Maria; Lucciarini, Roberta; Arancia, Silvia; Sandini, Silvia; Amantini, Consuelo; Cassone, Antonio

    2010-06-01

    Vulvovaginal candidiasis is a mucosal infection affecting many women, but the immune mechanisms operating against Candida albicans at the mucosal level remain unknown. A rat model was employed to further characterize the contribution of B and T cells to anti-Candida vaginal protection. Particularly, the protective role of vaginal B cells was studied by means of adoptive transfer of vaginal CD3(-) CD5(+) IgM(+) cells from Candida-immunized rats to naïve animals. This passive transfer of B cells resulted into a number of vaginal C. albicans CFU approximately 50% lower than their controls. Sorted CD3(-) CD5(+) IgM(+) vaginal B lymphocytes from Candida-infected rats proliferated in response to stimulation with an immunodominant mannoprotein (MP) antigen of the fungus. Importantly, anti-MP antibodies and antibody-secreting B cells were detected in the supernatant and cell cultures, respectively, of vaginal B lymphocytes from infected rats incubated in vitro with vaginal T cells and stimulated with MP. No such specific antibodies were found when using vaginal B cells from uninfected rats. Furthermore, inflammatory and anti-inflammatory cytokines, such as interleukin-2 (IL-2), IL-6 and IL-10, were found in the supernatant of vaginal B cells from infected rats. These data are evidence of a partial anti-Candida protective role of CD3(-) CD5(+) IgM(+) vaginal B lymphocytes in our experimental model.

  10. Investigating Delamination Migration in Composite Tape Laminates

    NASA Technical Reports Server (NTRS)

    Ratcliffe, James G.; DeCarvalho, Nelson V.

    2014-01-01

    A modification to a recently developed test specimen designed to investigate migration of a delamination between neighboring ply interfaces in tape laminates is presented. The specimen is a cross-ply laminated beam consisting of 40 plies with a polytetrafluoroethylene insert spanning part way along its length. The insert is located between a lower 0-degree ply (specimen length direction) and a stack of four 90-degree plies (specimen width direction). The modification involved a stacking sequence that promotes stable delamination growth prior to migration, and included a relocation of the insert from the specimen midplane to the interface between plies 14 and 15. Specimens were clamped at both ends onto a rigid baseplate and loaded on their upper surface via a piano hinge assembly, resulting in a predominantly flexural loading condition. Tests were conducted with the load-application point positioned at various locations along a specimen's span. This position affected the sequence of damage events during a test.

  11. Effect of vaginal or systemic estrogen on dynamics of collagen assembly in the rat vaginal wall.

    PubMed

    Montoya, T Ignacio; Maldonado, P Antonio; Acevedo, Jesus F; Word, R Ann

    2015-02-01

    The objective of this study was to compare the effects of systemic and local estrogen treatment on collagen assembly and biomechanical properties of the vaginal wall. Ovariectomized nulliparous rats were treated with estradiol or conjugated equine estrogens (CEEs) either systemically, vaginal CEE, or vaginal placebo cream for 4 wk. Low-dose local CEE treatment resulted in increased vaginal epithelial thickness and significant vaginal growth without uterine hyperplasia. Furthermore, vaginal wall distensibility increased without compromise of maximal force at failure. Systemic estradiol resulted in modest increases in collagen type I with no change in collagen type III mRNA. Low-dose vaginal treatment, however, resulted in dramatic increases in both collagen subtypes whereas moderate and high dose local therapies were less effective. Consistent with the mRNA results, low-dose vaginal estrogen resulted in increased total and cross-linked collagen content. The inverse relationship between vaginal dose and collagen expression may be explained in part by progressive downregulation of estrogen receptor-alpha mRNA with increasing estrogen dose. We conclude that, in this menopausal rat model, local estrogen treatment increased total and cross-linked collagen content and markedly stimulated collagen mRNA expression in an inverse dose-effect relationship. High-dose vaginal estrogen resulted in downregulation of estrogen receptor-alpha and loss of estrogen-induced increases in vaginal collagen. These results may have important clinical implications regarding the use of local vaginal estrogen therapy and its role as an adjunctive treatment in women with loss of vaginal support. © 2015 by the Society for the Study of Reproduction, Inc.

  12. Portable digital pressure indicator for calibrating magnetic tape recorders

    NASA Technical Reports Server (NTRS)

    Mccormick, Royce F.; Leighty, Bradley D.

    1989-01-01

    The design of a portable Digital Pressure Indicator (DPI) to be used for calibrating the pressure systems on Langley's magnetic tape recorders is described. High-speed magnetic tape recorders require pressure (0 to 20 psig) for providing an air cushion across the tape guides and a slight vacuum (30 inch H2O) for maintaining the proper number of tape loops in the advance and feed chamber. The DPI is a hand-held device that can be quickly coupled to a magnetic tape recorder and includes a two-position switch for selecting either measured pressure or vacuum, to be displayed digitally in engineering units (psig or inches H2O). The DPI is currently in use in Langley's Analysis and Computation Division.

  13. TMR tape drive for a 15 TB cartridge

    NASA Astrophysics Data System (ADS)

    Biskeborn, Robert G.; Fontana, Robert E.; Lo, Calvin S.; Czarnecki, W. Stanley; Liang, Jason; Iben, Icko E. T.; Decad, Gary M.; Hipolito, Venus A.

    2018-05-01

    This paper highlights the development of tunnel magnetoresistive (TMR) sensors for magnetic tape recording applications. This has led to the introduction of a tape drives supporting a 15 TB native tape cartridge, currently the highest capacity available. Underscoring this development is the fact that the TMR sensors must run in continual contact with the tape media. This is contrasted with modern hard disk drive (hdd) sensors, which fly above the disk platters. Various challenges encountered in developing and deploying TMR are presented. In addition, advances to the write transducer are also discussed. Lastly, the authors show that future density scaling for tape recording, unlike that for hdd, is not facing limits imposed by photolithography or superparamagnetic physics, suggesting that cartridge capacity improvements of 4 to 6x will be achieved in the next 4 to 8 years.

  14. Tools for applying lead tape to flat conductor cabling for chemical stripping

    NASA Technical Reports Server (NTRS)

    Angele, W.

    1969-01-01

    Two tools facilitate chemical stripping of insulation on flat conductor cabling. A tape pressing tool and a taping fixture apply adhesive lead tape with the proper amount of pressure to protect the remaining insulation from the chemical stripping solution.

  15. Efficacy of ProTaper Retreatment System in Root Canals Obturated with Gutta-Percha Using Two Different Sealers and GuttaFlow

    PubMed Central

    Siotia, Jaya; Acharya, Shashi Rashmi; Gupta, Sunil Kumar

    2011-01-01

    Objective. To compare the efficacy of ProTaper retreatment files in removing three different obturating materials. Study Design. Forty-five human, single-rooted premolars were divided into three experimental groups. Group 1 was obturated with gutta-percha and AH Plus sealer, Group 2 was obturated with gutta-percha and zinc oxide eugenol sealer, and Group 3 was obturated with GuttaFlow. Retreatment was done using the ProTaper universal rotary retreatment files. Root halves were visualized using magnifying loops at 3X magnification and optical stereomicroscope at 10X magnification. Images were analyzed using AutoCAD 2004 software to calculate area of the remaining debris in the canal. For statistical analysis were used variance test and ANOVA. Results. Total debris/canal area ratio between the three groups showed a statistically significant difference (P < 0.001). Conclusion. ProTaper retreatment system did not produce completely clean canals in any of the groups. However, it had the best efficacy towards removing silicon based obturating material GuttaFlow. PMID:22114598

  16. Causes and Diagnosis of Abnormal Vaginal Bleeding.

    PubMed

    Sokol, Elizabeth; Peddinti, Radhika

    2015-07-01

    Abnormal vaginal bleeding in a postmenarchal adolescent patient is most often related to dysfunctional uterine bleeding. However, there are other potential etiologies, including hematologic disorders, infections, and oncologic problems. We present a 12-year-old girl who presented with prolonged vaginal bleeding and was ultimately diagnosed with rhabdomyosarcoma. In this article, we discuss the approach to a patient with vaginal bleeding along with a more in-depth review of risk stratification in rhabdomyosarcoma, including treatment options such as chemotherapy, surgery, and radiation therapy. Copyright 2015, SLACK Incorporated.

  17. Vaginal rings for delivery of HIV microbicides

    PubMed Central

    Malcolm, R Karl; Fetherston, Susan M; McCoy, Clare F; Boyd, Peter; Major, Ian

    2012-01-01

    Following the successful development of long-acting steroid-releasing vaginal ring devices for the treatment of menopausal symptoms and contraception, there is now considerable interest in applying similar devices to the controlled release of microbicides against HIV. In this review article, the vaginal ring concept is first considered within the wider context of the early advances in controlled-release technology, before describing the various types of ring device available today. The remainder of the article highlights the key developments in HIV microbicide-releasing vaginal rings, with a particular focus on the dapivirine ring that is presently in late-stage clinical testing. PMID:23204872

  18. The Vaginal Microbiota and Urinary Tract Infection.

    PubMed

    Stapleton, Ann E

    2016-12-01

    The vagina is a key anatomical site in the pathogenesis of urinary tract infection (UTI) in women, serving as a potential reservoir for infecting bacteria and a site at which interventions may decrease the risk of UTI. The vaginal microbiota is a dynamic and often critical factor in this pathogenic interplay, because changes in the characteristics of the vaginal microbiota resulting in the loss of normally protective Lactobacillus spp. increase the risk of UTI. These alterations may result from the influence of estrogen deficiency, antimicrobial therapy, contraceptives, or other causes. Interventions to reduce adverse effects on the vaginal microbiota and/or to restore protective lactobacilli may reduce the risks of UTI.

  19. Proinflammatory Cytokines as Regulators of Vaginal Microbiota.

    PubMed

    Kremleva, E A; Sgibnev, A V

    2016-11-01

    It was shown that IL-1β, IL-8, and IL-6 in concentrations similar to those in the vagina of healthy women stimulated the growth of normal microflora (Lactobacillus spp.) and suppressed the growth and biofilm production by S. aureus and E. coli. On the contrary, these cytokines in higher concentrations typical of vaginal dysbiosis suppressed normal microflora and stimulated the growth of opportunistic microorganisms. TGF-β1 in both doses produced a stimulating effects on study vaginal microsymbionts. It is hypothesized that pro-inflammatory cytokines serve as the molecules of interspecies communication coordinating the interactions of all components of the vaginal symbiotic system.

  20. Vaginal rings for delivery of HIV microbicides.

    PubMed

    Malcolm, R Karl; Fetherston, Susan M; McCoy, Clare F; Boyd, Peter; Major, Ian

    2012-01-01

    Following the successful development of long-acting steroid-releasing vaginal ring devices for the treatment of menopausal symptoms and contraception, there is now considerable interest in applying similar devices to the controlled release of microbicides against HIV. In this review article, the vaginal ring concept is first considered within the wider context of the early advances in controlled-release technology, before describing the various types of ring device available today. The remainder of the article highlights the key developments in HIV microbicide-releasing vaginal rings, with a particular focus on the dapivirine ring that is presently in late-stage clinical testing.

  1. Resolution of Rectal Prolapse by Vaginal Reconstruction.

    PubMed

    Devakumar, Hemikaa; Chandrasekaran, Neeraja; Alas, Alexandriah; Martin, Laura; Davila, G Willy; Hurtado, Eric

    Rectal prolapse is a disorder of the pelvic floor in which the layers of the rectal mucosa protrude outward through the anus. Surgical repair is the mainstay of treatment. Options include intra-abdominal procedures such as rectopexy and perineal procedures such as the Delorme and Altemeier perineal rectosigmoidectomy. Rectal and vaginal prolapse can often coexist. However, to our knowledge, there are no reported cases of rectal prolapse resolved by the repair of a compressive enterocele abutting the anterior rectal wall through a vaginal approach alone. We present a novel case of rectal prolapse that resolved by correction of the vaginal defect. A 53-year-old female with prior history of abdominal hysterectomy, presented to the urogynecology clinic with complaints of vaginal bulge, urge urinary incontinence, and rectal bulge on straining with no fecal incontinence for several years. On physical examination, she was found to have stage 2 anterior, posterior, and apical vaginal prolapse and reducible rectal prolapse. Colorectal surgery (CRS) evaluation was requested, which revealed minimal anterior mucosal prolapse on Valsalva with no full-thickness prolapse. Magnetic resonance imaging (MRI) defecogram was performed, which demonstrated a large rectocele, enterocele, and small bowel prolapsing between the rectum and vagina during the evacuation phase, with no rectal prolapse. The decision to proceed with vaginal prolapse surgery without concomitant rectal prolapse repair was made, as the patient had no fecal incontinence, and the degree of rectal prolapse was minimal. On the day of surgery, which was 2 months later, she presented with a 2-cm anterior rectal prolapse with no incontinence. Colorectal surgery was consulted again, but unavailable. After counseling, the patient wished to proceed with her planned surgery. It was felt that correcting the anterior rectocele and enterocele, thereby eliminating the descent of the bowel on the anterior rectal wall, might cause

  2. Vaginal Calculus in a Woman With Mixed Urinary Incontinence and Vaginal Mesh Exposure.

    PubMed

    Winkelman, William D; Rabban, Joseph T; Korn, Abner P

    2016-01-01

    Vaginal calculi are extremely rare and are most commonly encountered in the setting of an urethrovaginal or vesicovaginal fistula. We present a case of a 72-year-old woman with mixed urinary incontinence and vaginal mesh exposure incidentally found to have a large vaginal calculus. We removed the calculus surgically and analyzed the components. Results demonstrated the presence of ammonium-magnesium phosphate hexahydrate and carbonate apatite.

  3. The interaction between vaginal microbiota, cervical length, and vaginal progesterone treatment for preterm birth risk.

    PubMed

    Kindinger, Lindsay M; Bennett, Phillip R; Lee, Yun S; Marchesi, Julian R; Smith, Ann; Cacciatore, Stefano; Holmes, Elaine; Nicholson, Jeremy K; Teoh, T G; MacIntyre, David A

    2017-01-19

    Preterm birth is the primary cause of infant death worldwide. A short cervix in the second trimester of pregnancy is a risk factor for preterm birth. In specific patient cohorts, vaginal progesterone reduces this risk. Using 16S rRNA gene sequencing, we undertook a prospective study in women at risk of preterm birth (n = 161) to assess (1) the relationship between vaginal microbiota and cervical length in the second trimester and preterm birth risk and (2) the impact of vaginal progesterone on vaginal bacterial communities in women with a short cervix. Lactobacillus iners dominance at 16 weeks of gestation was significantly associated with both a short cervix <25 mm (n = 15, P < 0.05) and preterm birth <34 +0  weeks (n = 18; P < 0.01; 69% PPV). In contrast, Lactobacillus crispatus dominance was highly predictive of term birth (n = 127, 98% PPV). Cervical shortening and preterm birth were not associated with vaginal dysbiosis. A longitudinal characterization of vaginal microbiota (<18, 22, 28, and 34 weeks) was then undertaken in women receiving vaginal progesterone (400 mg/OD, n = 25) versus controls (n = 42). Progesterone did not alter vaginal bacterial community structure nor reduce L. iners-associated preterm birth (<34 weeks). L. iners dominance of the vaginal microbiota at 16 weeks of gestation is a risk factor for preterm birth, whereas L. crispatus dominance is protective against preterm birth. Vaginal progesterone does not appear to impact the pregnancy vaginal microbiota. Patients and clinicians who may be concerned about "infection risk" associated with the use of a vaginal pessary during high-risk pregnancy can be reassured.

  4. FP core carrier technique: thermoplasticized gutta-percha root canal obturation technique using polypropylene core.

    PubMed

    Kato, Hiroshi; Nakagawa, Kan-Ichi

    2010-01-01

    Core carrier techniques are unique among the various root canal filling techniques for delivering and compacting gutta-percha in the prepared root canal system. Thermafil (TF), considered the major core carrier device, is provided as an obturator consisting of a master core coated with thermoplasticized gutta-percha. We have devised a thermoplasticized gutta-percha filling technique using a polypropylene core, FlexPoint® NEO (FP), which was developed as a canal filling material that can be sterilized in an autoclave. Therefore, FP can be coated onto thermoplasticized gutta-percha and inserted into the prepared canal as a core carrier. The FP core carrier technique offers many advantages over the TF system: the core can be tested in the root canal and verified radiographically; the core can be adjusted to fit and surplus material easily removed; furthermore the core can be easily removed for retreatment. The clinical procedure of the FP core carrier technique is simple, and similar that with the TF system. Thermoplasticized gutta-percha in a syringe is heated in an oven and extruded onto the FP core carrier after a trial insertion. The FP core carrier is inserted into the root canal to the working length. Excess FP is then removed with a red-hot plastic instrument at the orifice of the root canal. The FP core carrier technique incorporates the clinical advantages of the existing TF system while minimizing the disadvantages. Hence the FP core carrier technique is very useful in clinical practice. This paper describes the FP core carrier technique as a new core based method.

  5. Clinical effectiveness of the obturator externus muscle injection in chronic pelvic pain patients.

    PubMed

    Kim, Shin Hyung; Kim, Do Hyeong; Yoon, Duck Mi; Yoon, Kyung Bong

    2015-01-01

    Because of its anatomical location and function, the obturator externus (OE) muscle can be a source of pain; however, this muscle is understudied as a possible target for therapeutic intervention in pain practice. In this retrospective observational study, we evaluated the clinical effectiveness of the OE muscle injection with a local anesthetic in chronic pelvic pain patients with suspected OE muscle problems. Twenty-three patients with localized tenderness on the inferolateral side of the pubic tubercle accompanied by pain in the groin, anteromedial thigh, or hip were studied. After identifying the OE with contrast dye under fluoroscopic guidance, 5 to 8 mL of 0.3% lidocaine was injected. Pain scores were assessed before and after injection; patient satisfaction was also assessed. Mean pain score decreased by 44.7% (6.6 ± 1.8 to 3.5 ± 0.9, P < 0.001) 2 weeks after OE muscle injection as compared with pain score before injection. In addition, 82% of patients (19 of 23 patients) reported excellent or good satisfaction during 2 weeks after injection. No patients reported complications from OE muscle injection. Fluoroscopy-guided injection of the OE muscle with local anesthetic reduced pain scores and led to a high level of satisfaction at short-term follow-up in patients with suspected OE muscle problem. The results of this study suggest that OE muscle injection may be a valuable therapeutic option for a select group of chronic pelvic pain patients who present with localized tenderness in the OE muscle that is accompanied by groin, anteromedial thigh, or hip pain. © 2013 World Institute of Pain.

  6. Quantitative studies on the vaginal flora of asymptomatic women and patients with vaginitis and vaginosis.

    PubMed

    Hammann, R; Kronibus, A; Lang, N; Werner, H

    1987-07-01

    Vaginal washings of 22 patients with vaginitis, 11 with vaginosis, and 12 healthy subjects were investigated quantitatively and qualitatively for aerobic and anaerobic bacteria and yeasts. Gardnerella vaginalis was recovered from 9 of the vaginitis patients, 7 of the vaginosis patients, and 4 of the asymptomatic subjects. Obligate anaerobes were found in 11 of the vaginitis patients, 4 of the vaginosis patients, and none of the control subjects. Bacteroides bivius was the anaerobe most frequently isolated from symptomatic subjects. Anaerobic vibrios were recovered twice from symptomatic subjects. The counts for Gardnerella vaginalis and anaerobes when present were generally very high. The most frequent aerobes were beta-hemolytic streptococci (group B) and staphylococci.

  7. Prevalence of vaginal candidiasis among pregnant women with abnormal vaginal discharge in Maiduguri.

    PubMed

    Ibrahim, S M; Bukar, M; Mohammed, Y; Mohammed, B; Yahaya, M; Audu, B M; Ibrahim, H M; Ibrahim, H A

    2013-01-01

    Pregnancy represents a risk factor in the occurrence of vaginal candidiasis. To determine the prevalence and clinical features associated with abnormal vaginal discharge and C. albicans infection in pregnant women. High vaginal swab samples and data on epidemiological characteristics were collected from 400 pregnant women with complaints of abnormal vaginal discharge at booking clinic of University of Maiduguri Teaching Hospital. The data was analysed using SPSS 16.0 statistical software. The prevalence of abnormal vaginal discharge in pregnancy was 31.5%. The frequency of abnormal vaginal discharge was 183 (45.8%) among those aged 20-24 years, 291 (72.8%) in multipara, 223 (55.8%) in those with Primary education and 293 (73.2%) in unemployed. Vulval pruritus 300 (75.0%) was significantly related to abnormal vaginal discharge (P < 0.001). The prevalence of C. albicans was 41%. The frequencies of Vulval itching, Dyspareunia and vulval excoriation among those with candidiasis were 151 (50.3%), 14 (56.0%) and 75 (75.0%) respectively (P < 0.001). The prevalence of abnormal vaginal discharge in pregnancy was high in this study and C. albicans was the commonest cause. It is recommended that a pregnant woman complaining of abnormal vaginal discharge be assessed and Laboratory diagnosis done in order to give appropriate treatment.

  8. Simulation and analysis of tape spring for deployed space structures

    NASA Astrophysics Data System (ADS)

    Chang, Wei; Cao, DongJing; Lian, MinLong

    2018-03-01

    The tape spring belongs to the configuration of ringent cylinder shell, and the mechanical properties of the structure are significantly affected by the change of geometrical parameters. There are few studies on the influence of geometrical parameters on the mechanical properties of the tape spring. The bending process of the single tape spring was simulated based on simulation software. The variations of critical moment, unfolding moment, and maximum strain energy in the bending process were investigated, and the effects of different radius angles of section and thickness and length on driving capability of the simple tape spring was studied by using these parameters. Results show that the driving capability and resisting disturbance capacity grow with the increase of radius angle of section in the bending process of the single tape spring. On the other hand, these capabilities decrease with increasing length of the single tape spring. In the end, the driving capability and resisting disturbance capacity grow with the increase of thickness in the bending process of the single tape spring. The research has a certain reference value for improving the kinematic accuracy and reliability of deployable structures.

  9. Interpretation of the human skin biotribological behaviour after tape stripping.

    PubMed

    Pailler-Mattei, C; Guerret-Piécourt, C; Zahouani, H; Nicoli, S

    2011-07-06

    The present study deals with the modification of the human skin biotribological behaviour after tape stripping. The tape-stripping procedure consists in the sequential application and removal of adhesive tapes on the skin surface in order to remove stratum corneum (SC) layers, which electrically charges the skin surface. The skin electric charges generated by tape stripping highly change the skin friction behaviour by increasing the adhesion component of the skin friction coefficient. It has been proposed to rewrite the friction adhesion component as the sum of two terms: the first classical adhesion term depending on the intrinsic shear strength, τ(0), and the second term depending on the electric shear strength, τ(elec). The experimental results allowed to estimate a numerical value of the electric shear strength τ(elec). Moreover, a plan capacitor model with a dielectric material inside was used to modelize the experimental system. This physical model permitted to evaluate the friction electric force and the electric shear strength values to calculate the skin friction coefficient after the tape stripping. The comparison between the experimental and the theoretical value of the skin friction coefficient after the tape stripping has shown the importance of the electric charges on skin biotribological behaviour. The static electric charges produced by tape stripping on the skin surface are probably able to highly modify the interaction of formulations with the skin surface and their spreading properties. This phenomenon, generally overlooked, should be taken into consideration as it could be involved in alteration of drug absorption.

  10. Interpretation of the human skin biotribological behaviour after tape stripping

    PubMed Central

    Pailler-Mattei, C.; Guerret-Piécourt, C.; Zahouani, H.; Nicoli, S.

    2011-01-01

    The present study deals with the modification of the human skin biotribological behaviour after tape stripping. The tape-stripping procedure consists in the sequential application and removal of adhesive tapes on the skin surface in order to remove stratum corneum (SC) layers, which electrically charges the skin surface. The skin electric charges generated by tape stripping highly change the skin friction behaviour by increasing the adhesion component of the skin friction coefficient. It has been proposed to rewrite the friction adhesion component as the sum of two terms: the first classical adhesion term depending on the intrinsic shear strength, τ0, and the second term depending on the electric shear strength, τelec. The experimental results allowed to estimate a numerical value of the electric shear strength τelec. Moreover, a plan capacitor model with a dielectric material inside was used to modelize the experimental system. This physical model permitted to evaluate the friction electric force and the electric shear strength values to calculate the skin friction coefficient after the tape stripping. The comparison between the experimental and the theoretical value of the skin friction coefficient after the tape stripping has shown the importance of the electric charges on skin biotribological behaviour. The static electric charges produced by tape stripping on the skin surface are probably able to highly modify the interaction of formulations with the skin surface and their spreading properties. This phenomenon, generally overlooked, should be taken into consideration as it could be involved in alteration of drug absorption. PMID:21227961

  11. Treatment Options by Stage (Vaginal Cancer)

    MedlinePlus

    ... stage of the cancer being treated. External and internal radiation therapy are used to treat vaginal cancer, and may also be used as palliative therapy to relieve symptoms and improve quality of life . Chemotherapy Chemotherapy is a cancer treatment ...

  12. Vaginal Bleeding: MedlinePlus Health Topic

    MedlinePlus

    ... Bleeding (American Academy of Family Physicians) Also in Spanish Abnormal Uterine Bleeding (Beyond the Basics) (UpToDate) Abnormal ... College of Obstetricians and Gynecologists) - PDF Also in Spanish Vaginal Bleeding (Mayo Foundation for Medical Education and ...

  13. Application of vaginal temperature measurement in bitches.

    PubMed

    Maeder, B; Arlt, S; Burfeind, O; Heuwieser, W

    2012-12-01

    Finding innovative, non-invasive methods for continuously measuring body temperature minimizing human interference is important for accurate data collection. The objective of this study was to assess feasibility and accuracy of continuous body temperature measurements with loggers placed in the vaginal cavity of bitches. First, an in vitro experiment was performed to compare values obtained by temperature loggers (n = 26) to a calibrated liquid-in-glass thermometer. The mean differences between the two methods were low. Next, an in vivo experiment was performed using five healthy bitches, and values obtained by the vaginal loggers were compared to measurements collected rectally with digital thermometers. The results show that rectal and vaginal temperatures were correlated. The mean differences between rectal and vaginal temperatures were negligible. We conclude that the utilized temperature loggers provide accurate and reliable data. © 2012 Blackwell Verlag GmbH.

  14. Vaginal Discharge: What's Normal, What's Not

    MedlinePlus

    ... Discharge? Vaginal infections, such as bacterial vaginosis , candidiasis ( yeast infection ), and trichomoniasis are common causes of abnormal ... having sex, such as bacterial vaginosis or a yeast infection. If you notice any changes in your ...

  15. Vaginal itching and discharge - Adult and adolescent

    MedlinePlus

    ... 003158.htm Vaginal itching and discharge - adult and adolescent To use the sharing features on this page, ... fabric softeners, feminine sprays, ointments, creams, douches, and contraceptive foams or jellies or creams. This may irritate ...

  16. 21 CFR 884.3900 - Vaginal stent.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... stent. (a) Identification. A vaginal stent is a device used to enlarge the vagina by stretching, or to support the vagina and to hold a skin graft after reconstructive surgery. (b) Classification. Class II...

  17. 21 CFR 884.3900 - Vaginal stent.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... stent. (a) Identification. A vaginal stent is a device used to enlarge the vagina by stretching, or to support the vagina and to hold a skin graft after reconstructive surgery. (b) Classification. Class II...

  18. 21 CFR 884.3900 - Vaginal stent.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... stent. (a) Identification. A vaginal stent is a device used to enlarge the vagina by stretching, or to support the vagina and to hold a skin graft after reconstructive surgery. (b) Classification. Class II...

  19. 21 CFR 884.3900 - Vaginal stent.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... stent. (a) Identification. A vaginal stent is a device used to enlarge the vagina by stretching, or to support the vagina and to hold a skin graft after reconstructive surgery. (b) Classification. Class II...

  20. Vaginal birth after C-section

    MedlinePlus

    ... gov/ency/patientinstructions/000589.htm Vaginal birth after C-section To use the sharing features on this ... enable JavaScript. If you had a cesarean birth (C-section) before, it does not mean that you ...

  1. Optical clearing of vaginal tissues in cadavers

    NASA Astrophysics Data System (ADS)

    Chang, Chun-Hung; Hardy, Luke A.; Peters, Michael G.; Bastawros, Dina A.; Myers, Erinn M.; Kennelly, Michael J.; Fried, Nathaniel M.

    2018-02-01

    A nonsurgical laser procedure is being developed for treatment of female stress urinary incontinence (SUI). Previous studies in porcine vaginal tissues, ex vivo, as well as computer simulations, showed the feasibility of using near-infrared laser energy delivered through a transvaginal contact cooling probe to thermally remodel endopelvic fascia, while preserving the vaginal wall from thermal damage. This study explores optical properties of vaginal tissue in cadavers as an intermediate step towards future pre-clinical and clinical studies. Optical clearing of tissue using glycerol resulted in a 15-17% increase in optical transmission after 11 min at room temperature (and a calculated 32.5% increase at body temperature). Subsurface thermal lesions were created using power of 4.6 - 6.4 W, 5.2-mm spot, and 30 s irradiation time, resulting in partial preservation of vaginal wall to 0.8 - 1.1 mm depth.

  2. How Do Health Care Providers Diagnose Vaginitis?

    MedlinePlus

    ... Share Facebook Twitter Pinterest Email Print How do health care providers diagnose vaginitis? To find out the cause of a woman's symptoms, her health care provider will Examine the vagina, the vulva, and ...

  3. Systematic Review of the Effect of Taping Techniques on Patellofemoral Pain Syndrome.

    PubMed

    Logan, Catherine A; Bhashyam, Abhiram R; Tisosky, Ashley J; Haber, Daniel B; Jorgensen, Anna; Roy, Adam; Provencher, Matthew T

    Taping is commonly used in the management of several musculoskeletal conditions, including patellofemoral pain syndrome (PFPS). Specific guidelines for taping are unknown. To investigate the efficacy of knee taping in the management of PFPS. Our hypothesis was that tension taping and exercise would be superior to placebo taping and exercise as well as to exercise or taping alone. The PubMed/MEDLINE, Cochrane, Rehabilitation and Sports Medicine Source, and CINAHL databases were reviewed for English-language randomized controlled trials (RCTs) evaluating the efficacy of various taping techniques that were published between 1995 and April 2015. Keywords utilized included taping, McConnell, kinesio-taping, kinesiotaping, patellofemoral pain, and knee. Studies included consisted of RCTs (level 1 or 2) with participants of all ages who had anterior knee or patellofemoral pain symptoms and had received nonsurgical management using any taping technique. Systematic review. Level 2. A checklist method was used to determine selection, performance, detection, and attrition bias for each article. A quality of evidence grading was then referenced using the validated PEDro database for RCTs. Three difference comparison groups were compared: tension taping and exercise versus placebo taping and exercise (group 1), placebo taping and exercise versus exercise alone (group 2), and tension taping and exercise versus taping alone (group 3). Five RCTs with 235 total patients with multiple intervention arms were included. Taping strategies included McConnell and Kinesiotaping. Visual analog scale (VAS) scores indicated improvement in all 3 comparison groups (group 1: 91 patients, 39% of total, mean VAS improvement 44.9 [tension taping + exercise] vs 66 [placebo taping + exercise]; group 2: 56 patients, 24% of total, mean VAS improvement 66 [placebo taping + exercise] vs 47.6 [exercise alone]; and group 3: 112 patients, 48% of total, mean VAS improvement 44.9 [tension taping + exercise

  4. A case for automated tape in clinical imaging.

    PubMed

    Bookman, G; Baune, D

    1998-08-01

    Electronic archiving of radiology images over many years will require many terabytes of storage with a need for rapid retrieval of these images. As more large PACS installations are installed and implemented, a data crisis occurs. The ability to store this large amount of data using the traditional method of optical jukeboxes or online disk alone becomes an unworkable solution. The amount of floor space number of optical jukeboxes, and off-line shelf storage required to store the images becomes unmanageable. With the recent advances in tape and tape drives, the use of tape for long term storage of PACS data has become the preferred alternative. A PACS system consisting of a centrally managed system of RAID disk, software and at the heart of the system, tape, presents a solution that for the first time solves the problems of multi-modality high end PACS, non-DICOM image, electronic medical record and ADT data storage. This paper will examine the installation of the University of Utah, Department of Radiology PACS system and the integration of automated tape archive. The tape archive is also capable of storing data other than traditional PACS data. The implementation of an automated data archive to serve the many other needs of a large hospital will also be discussed. This will include the integration of a filmless cardiology department and the backup/archival needs of a traditional MIS department. The need for high bandwidth to tape with a large RAID cache will be examined and how with an interface to a RIS pre-fetch engine, tape can be a superior solution to optical platters or other archival solutions. The data management software will be discussed in detail. The performance and cost of RAID disk cache and automated tape compared to a solution that includes optical will be examined.

  5. [IMPROVEMENT AND CHOICE OF COLOSTOMY METHOD IN THE TREATMENT OF PATIENTS, SUFFERING AN ACUTE OBTURATIVE IMPASSABILITY OF LARGE BOWEL].

    PubMed

    Kustryo, V I; Langazo, O V

    2015-11-01

    Colostomy was done in 49 patients, suffering an acute obturative impassability of large bowel (AOILB). In 28 patients (1st group) colostomy was conducted in accordance to standard method; in 21 (2nd group)--in accordance to the method, proposed by us. Application of the method proposed for surgical treatment of AOILB have guaranteed a reduction of postoperative paracolostomal complications rate in 6.8 times, of postoperative lethality--in 2.2 times, duration of the patient stationary treatment--in 1.4 times, the rate of dressings and the dressing material expanses--in 10 times.

  6. Vaginal microbiota and viral sexually transmitted diseases.

    PubMed

    Nardis, C; Mosca, L; Mastromarino, P

    2013-01-01

    Healthy vaginal microbiota is an important biological barrier to pathogenic microorganisms. When this predominantly Lactobacillus community is disrupted, decreased in abundance and replaced by different anaerobes, bacterial vaginosis (BV) may occur. BV is associated with prevalence and incidence of several sexually transmitted infections. This review provides background on BV, discusses the epidemiologic data to support a role of altered vaginal microbiota for acquisition of sexually transmitted diseases and analyzes mechanisms by which lactobacilli could counteract sexually transmitted viral infections.

  7. Effect of vaginal estrogen on pessary use

    PubMed Central

    Dessie, Sybil G.; Armstrong, Katherine; Modest, Anna M.; Hacker, Michele R.

    2016-01-01

    Introduction and hypothesis Many providers recommend concurrent estrogen therapy with pessary use to limit complications; however, limited data exist to support this practice. We hypothesized that vaginal estrogen supplementation decreases incidence of pessary-related complications and discontinuation. Methods We performed a retrospective cohort study of women who underwent a pessary fitting from 1 January 2007 through 1 September 2013 at one institution; participants were identified by billing code and were eligible if they were post-menopausal and had at least 3 months of pessary use and 6 months of follow-up. All tests were two sided, and P values < 0.05 were considered statistically significant. Results Data from 199 women were included; 134 used vaginal estrogen and 65 did not. Women who used vaginal estrogen had a longer median follow-up time (29.5 months) compared with women who did not (15.4 months) and were more likely to have at least one pessary check (98.5 % vs 86.2 %, P < 0.001). Those in the estrogen group were less likely to discontinue using their pessary (30.6 % vs 58.5 %, P < 0.001) and less likely to develop increased vaginal discharge than women who did not [hazard ratio (HR) 0.31, 95 % confidence interval (CI) 0.17–0.58]. Vaginal estrogen was not protective against erosions (HR 0.93, 95 % CI 0.54–1.6) or vaginal bleeding (HR 0.78, 95 % CI 0.36–1.7). Conclusions Women who used vaginal estrogen exhibited a higher incidence of continued pessary use and lower incidence of increased vaginal discharge than women who did not. PMID:26992727

  8. Methods of Measuring Stress Relaxation in Composite Tape Springs

    DTIC Science & Technology

    2015-03-26

    plate in order to spread the load evenly and prevent excess torque . The plate also allows for force on the tape spring to be applied to the entire...aluminum squares that can be tightened to the base. The test fixture is secured to the marble base. The tape springs are folded in three locations with...top plate is pressed down by tightening the bolt on each nut. The tightening is complete when the tape spring just begins to create an M shape and

  9. Freeze Tape Casting of Functionally Graded Porous Ceramics

    NASA Technical Reports Server (NTRS)

    Sofie, Stephen W.

    2007-01-01

    Freeze tape casting is a means of making preforms of ceramic sheets that, upon subsequent completion of fabrication processing, can have anisotropic and/or functionally graded properties that notably include aligned and graded porosity. Freeze tape casting was developed to enable optimization of the microstructures of porous ceramic components for use as solid oxide electrodes in fuel cells: Through alignment and grading of pores, one can tailor surface areas and diffusion channels for flows of gas and liquid species involved in fuel-cell reactions. Freeze tape casting offers similar benefits for fabrication of optimally porous ceramics for use as catalysts, gas sensors, and filters.

  10. Vaginal microbial flora and outcome of pregnancy.

    PubMed

    Donati, Laura; Di Vico, Augusto; Nucci, Marta; Quagliozzi, Lorena; Spagnuolo, Terryann; Labianca, Antonietta; Bracaglia, Marina; Ianniello, Francesca; Caruso, Alessandro; Paradisi, Giancarlo

    2010-04-01

    The vaginal microflora of a healthy asymptomatic woman consists of a wide variety of anaerobic and aerobic bacterial genera and species dominated by the facultative, microaerophilic, anaerobic genus Lactobacillus. The activity of Lactobacillus is essential to protect women from genital infections and to maintain the natural healthy balance of the vaginal flora. Increasing evidence associates abnormalities in vaginal flora during pregnancy with preterm labor and delivery with potential neonatal sequelae due to prematurity and poor perinatal outcome. Although this phenomenon is relatively common, even in populations of women at low risk for adverse events, the pathogenetic mechanism that leads to complications in pregnancy is still poorly understood. This review summarizes the current knowledge and uncertainties in defining alterations of vaginal flora in non-pregnant adult women and during pregnancy, and, in particular, investigates the issue of bacterial vaginosis and aerobic vaginitis. This could help specialists to identify women amenable to treatment during pregnancy leading to the possibility to reduce the preterm birth rate, preterm premature rupture of membranes, chorioamnionitis, neonatal, puerperal and maternal-fetal infectious diseases. Vaginal ecosystem study with the detection of pathogens is a key instrument in the prevention of preterm delivery, pPROM, chorioamnionitis, neonatal, puerperal and maternal-fetal infections.

  11. The vaginal microbiome: rethinking health and diseases

    PubMed Central

    Ma, Bing; Forney, Larry J.; Ravel, Jacques

    2013-01-01

    Vaginal microbiota form a mutually beneficial relationship with their host and have major impact on health and disease. In recent years our understanding of vaginal bacterial community composition and structure has significantly broadened as a result of investigators using cultivation-independent methods based on the analysis of 16S ribosomal RNA (rRNA) gene sequences. In asymptomatic, otherwise healthy women, several kinds of vaginal microbiota exist, the majority often dominated by species of Lactobacillus, while others comprise a diverse array of anaerobic microorganisms. Bacterial vaginosis is the most common vaginal conditions and is vaguely characterized as the disruption of the equilibrium of the ‘normal’ vaginal microbiots. A better understanding of ‘normal’ and ‘healthy’ vaginal ecosystems that is based on its ‘true’ function and not simply on its composition would help better define health and further improve disease diagnostics as well as the development of more personalized regimens to promote health and treat diseases. PMID:22746335

  12. An Experimental Investigation of Damaged Arresting Gear Tapes for the Langley Aircraft Landing Dynamics Facility

    NASA Technical Reports Server (NTRS)

    Mason, Angela J.

    1999-01-01

    An experimental investigation was performed on damaged arresting gear tapes at the Langley Aircraft Landing Dynamics Facility. The arrestment system uses five pairs of tapes to bring the test carriage to a halt. The procedure used to determine when to replace the tapes consists of a close evaluation of each of the 10 tapes after each run. During this evaluation, each tape is examined thoroughly and any damage observed on the tape is recorded. If the damaged tape does not pass the inspection, the tape is replaced with a new one. For the past 13 years, the most commonly seen damage types are edge fray damage and transverse damage. Tests were conducted to determine the maximum tensile strength of a damaged arresting gear tape specimen. The data indicate that tapes exhibiting transverse damage can withstand higher loads than tapes with edge fray damage.

  13. Improving the Spacelab mass memory unit tape layout with a simulation model

    NASA Technical Reports Server (NTRS)

    Noneman, S. R.

    1984-01-01

    A tape drive called the Mass Memory Unit (MMU) stores software used by Spacelab computers. MMU tape motion must be minimized during typical flight operations to avoid a loss of scientific data. A projection of the tape motion is needed for evaluation of candidate tape layouts. A computer simulation of the scheduled and unscheduled MMU tape accesses is developed for this purpose. This simulation permits evaluations of candidate tape layouts by tracking and summarizing tape movements. The factors that affect tape travel are investigated and a heuristic is developed to find a good tape layout. An improved tape layout for Spacelab I is selected after the evaluation of fourteen candidates. The simulation model will provide the ability to determine MMU layouts that substantially decrease the tape travel on future Spacelab flights.

  14. 13 point video tape quality guidelines

    SciTech Connect

    Gaunt, R.

    1997-05-01

    Until high definition television (ATV) arrives, in the U.S. we must still contend with the National Television Systems Committee (NTSC) video standard (or PAL or SECAM-depending on your country). NTSC, a 40-year old standard designed for transmission of color video camera images over a small bandwidth, is not well suited for the sharp, full-color images that todays computers are capable of producing. PAL and SECAM also suffers from many of NTSC`s problems, but to varying degrees. Video professionals, when working with computer graphic (CG) images, use two monitors: a computer monitor for producing CGs and an NTSC monitor to viewmore » how a CG will look on video. More often than not, the NTSC image will differ significantly from the CG image, and outputting it to NTSC as an artist works enables the him or her to see the images as others will see it. Below are thirteen guidelines designed to increase the quality of computer graphics recorded onto video tape. Viewing your work in NTSC and attempting to follow the below tips will enable you to create higher quality videos. No video is perfect, so don`t expect to abide by every guideline every time.« less

  15. STS-94 Mission Highlights Resource Tape

    NASA Technical Reports Server (NTRS)

    1997-01-01

    The flight crew of STS-94, Cmdr. James D. Halsell, Jr., Pilot Susan L. Still, Payload Cmdr. Janice E. Voss, Mission Specialists Micheal L. Gernhardt and Donald A. Thomas, and Payload Specialists Gregory T. Linteris and Roger K. Crouch can be seen preforming pre-launch activities such as eating the traditional breakfast, crew suit-up, and the ride out to the launch pad. Also, included are various panoramic views of the shuttle on the pad. The crew can be seen being readied in the white room' for their mission. After the closing of the hatch and arm retraction, launch activities are shown including countdown, engine ignition, launch, and the separation of the Solid Rocket Boosters. The crew is seen continuing the payload activation process, as the research efforts of the Microgravity Science Laboratory (MSL) mission get into full swing. The crew is seen in the Microgravity Science Laboratory aboard Space Shuttle Columbia activating the final experiment facility and beginning additional experiments, among the more than 30 investigations to be conducted during the 16-day mission. The tape concludes with the re-entery and landing of the Shuttle.

  16. REBCO tape performance under high magnetic field

    NASA Astrophysics Data System (ADS)

    Benkel, Tara; Miyoshi, Yasuyuki; Chaud, Xavier; Badel, Arnaud; Tixador, Pascal

    2017-08-01

    New improvements in high temperature superconductors (HTS) make them a promising candidate for building the next generation of high field magnets. As the conductors became recently available in long length, new projects such as NOUGAT (new magnet generation to generate Tesla at low cost) were started. This project aims at designing and building an HTS magnet prototype generating 10 T inside a 20 T resistive magnet. In this configuration, severe mechanical stress is applied on the insert and its extremities are subject to a high transverse component of the field. Because the conductor has anisotropic properties, it has to be studied carefully under similar conditions as the final prototype. First, this paper presents both the NOUGAT project and its context. Then, it shows the experimental results on short HTS tapes studied under high magnetic field up to 23 T with varying orientation. These results allow validating the current margin of the prototype. Finally, a first wound prototype is presented with experimental results up to 200 A under 16 T. Contribution to the topical issue "Electrical Engineering Symposium (SGE 2016)", edited by Adel Razek

  17. Shuttle-Data-Tape XML Translator

    NASA Technical Reports Server (NTRS)

    Barry, Matthew R.; Osborne, Richard N.

    2005-01-01

    JSDTImport is a computer program for translating native Shuttle Data Tape (SDT) files from American Standard Code for Information Interchange (ASCII) format into databases in other formats. JSDTImport solves the problem of organizing the SDT content, affording flexibility to enable users to choose how to store the information in a database to better support client and server applications. JSDTImport can be dynamically configured by use of a simple Extensible Markup Language (XML) file. JSDTImport uses this XML file to define how each record and field will be parsed, its layout and definition, and how the resulting database will be structured. JSDTImport also includes a client application programming interface (API) layer that provides abstraction for the data-querying process. The API enables a user to specify the search criteria to apply in gathering all the data relevant to a query. The API can be used to organize the SDT content and translate into a native XML database. The XML format is structured into efficient sections, enabling excellent query performance by use of the XPath query language. Optionally, the content can be translated into a Structured Query Language (SQL) database for fast, reliable SQL queries on standard database server computers.

  18. Successful vaginal delivery at term after vaginal reconstruction with labium minus flaps in a patient with vaginal atresia: A rare case report.

    PubMed

    Liu, Yu; Wang, Yi-Feng

    2017-07-01

    We report a case of successful vaginal delivery after vaginal reconstruction with labium minus flaps in a 23-year-old patient with congenital vaginal atresia. The patient primarily presented with amenorrhea and cyclic abdominal pain; transabdominal ultrasonography revealed an enlarged uterus due to hematometra and absence of the lower segment of the vagina. Eight years ago, she had undergone an unsuccessful attempt at canalization at a local hospital. Upon referral to our hospital, she underwent vaginal reconstruction with labium minus flaps. Four months after this procedure, she became pregnant and, subsequently, successfully and safely vaginally delivered a healthy female baby weighing 3250 g at 38 +1 weeks' gestation. The delivery did not involve perineal laceration by lateral episiotomy. To the best of our knowledge, this is the first reported case of successful vaginal delivery at term after vaginal reconstruction with labium minus flaps in a patient with vaginal atresia. © 2017 Japan Society of Obstetrics and Gynecology.

  19. Nonspecific aerobic vaginitis and pregnancy.

    PubMed

    Curzik, D; Drazancić, A; Hrgović, Z

    2001-01-01

    During the period 1996-1998, cervical swabs of 50 pregnant women with subacute amniotic infection syndrome (AIS) and the semen of their consorts were bacteriologically analyzed. In the control group were 50 healthy pregnant women and their consorts too. Pathogenic bacteria (the most common were Escherichia coli, Staphylococcus haemolyticus, Chlamydia trachomatis and Ureaplasma urealyticum) were isolated from the cervical swab of 50 pregnant patients with AIS in 86.0% of them, while in the control group of healthy pregnant women in 28.0%. Pathogenic bacteria were present in 70.0% of semen of consorts pregnant women with AIS and only in 30.0% of semen of the control group. The congruity of pathogenic bacteria in the cervical swab and semen in the investigated group was 69.2%, while only 35.7% in the control group. Following erythromycin, cefuroxime and local tetracyclin treatment, the negativization of the cervical swab resulted in 30 pregnant patients with AIS, while the colonization persisted in 20 of them. The outcome of pregnancy was significantly better in cases with negativization of the cervical swab: perinatal loss was 6.7%, while in cases with persistent infection it was 55.0%. The authors presume the amniotic infection syndrome should be ascending manifestation of nonspecific vaginitis, which is maintained by the consort's urogenital infection. AIS should be classified as a 'sexually-transmitted disease'. Copyright 2001 S. Karger AG, Basel

  20. Vaginal orgasm is associated with vaginal (not clitoral) sex education, focusing mental attention on vaginal sensations, intercourse duration, and a preference for a longer penis.

    PubMed

    Brody, Stuart; Weiss, Petr

    2010-08-01

    Evidence was recently provided for vaginal orgasm, orgasm triggered purely by penile-vaginal intercourse (PVI), being associated with better psychological functioning. Common sex education and sexual medicine approaches might undermine vaginal orgasm benefits. To examine the extent to which women's vaginal orgasm consistency is associated with (i) being told in childhood or adolescence that the vagina was the important zone for inducing female orgasm; (ii) how well they focus mentally on vaginal sensations during PVI; (iii) greater PVI duration; and (iv) preference for above-average penis length.   In a representative sample of the Czech population, 1,000 women reported their vaginal orgasm consistency (from never to almost every time; only 21.9% never had a vaginal orgasm), estimates of their typical foreplay and PVI durations, what they were told in childhood and adolescence was the important zone for inducing female orgasm, their degree of focus on vaginal sensations during PVI, and whether they were more likely to orgasm with a longer than average penis. The association of vaginal orgasm consistency with the predictors noted above. Vaginal orgasm consistency was associated with all hypothesized correlates. Multivariate analysis indicated the most important predictors were being educated that the vagina is important for female orgasm, being mentally focused on vaginal sensations during PVI, and in some analyses duration of PVI (but not foreplay) and preferring a longer than average penis. Focusing attention on penile-vaginal sensation supports vaginal orgasm and the myriad benefits thereof. Brody S, and Weiss P. Vaginal orgasm is associated with vaginal (not clitoral) sex education, focusing mental attention on vaginal sensations, intercourse duration, and a preference for a longer penis. © 2009 International Society for Sexual Medicine.

  1. Clinical approach to vaginal/vestibular masses in the bitch.

    PubMed

    Manothaiudom, K; Johnston, S D

    1991-05-01

    The most common causes of vaginal/vestibular masses in the bitch are vaginal prolapse, vaginal neoplasia, and urethral neoplasia protruding into the vaginal vault. Other possible causes are clitoral enlargement, vaginal polyps, uterine prolapse, and vaginal abscessation or hematoma. Vaginal prolapse usually can be distinguished from neoplasia by the age of the patient, the time of occurrence during the estrous cycle, and the site of origin of the mass. Prolapse usually occurs in bitches under 4 years of age during proestrus, estrus, or at the end of diestrus and usually arises from the floor of the vagina, except for urethral tumors that protrude from the external urethral orifice. Appropriate diagnostic workup of bitches with vaginal vestibular masses includes complete history and physical examination, vaginal cytologic and vaginoscopic examination, retrograde vaginography or urethrocystography, serum progesterone and estradiol concentrations, and, in the case of suspect neoplasms, surgical or excision biopsy of the mass.

  2. Measure Guideline: Guidance on Taped Insulating Sheathing Drainage Planes

    SciTech Connect

    Grin, A.; Lstiburek, J.

    The goal of this research is to provide durable and long-term water management solutions using exterior insulating sheathing as part of the water management system. It is possible to tape or seal the joints in insulating sheathing to create a drainage plane and even an air control layer. There exists the material durability component of the tape as well as the system durability component being the taped insulating sheathing as the drainage plane. This measure guideline provides best practice and product recommendations from the interviewed contractors and homebuilders who collectively have a vast amount of experience. Three significant issues weremore » discussed with the group, which are required to make taped insulating sheathing a simple, long-term, and durable drainage plane: horizontal joints should be limited or eliminated wherever possible; where a horizontal joint exists use superior materials; and frequent installation inspection and regular trade training are required to maintain proper installation.« less

  3. 12. "TAPE ROOM" LOCATED AT SOUTHEAST CORNER OF MAIN ROOM. ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    12. "TAPE ROOM" LOCATED AT SOUTHEAST CORNER OF MAIN ROOM. - Edwards Air Force Base, Air Force Rocket Propulsion Laboratory, Instrumentation & Control Building, Test Area 1-115, northwest end of Saturn Boulevard, Boron, Kern County, CA

  4. ICI optical data storage tape: An archival mass storage media

    NASA Technical Reports Server (NTRS)

    Ruddick, Andrew J.

    1993-01-01

    At the 1991 Conference on Mass Storage Systems and Technologies, ICI Imagedata presented a paper which introduced ICI Optical Data Storage Tape. This paper placed specific emphasis on the media characteristics and initial data was presented which illustrated the archival stability of the media. More exhaustive analysis that was carried out on the chemical stability of the media is covered. Equally important, it also addresses archive management issues associated with, for example, the benefits of reduced rewind requirements to accommodate tape relaxation effects that result from careful tribology control in ICI Optical Tape media. ICI Optical Tape media was designed to meet the most demanding requirements of archival mass storage. It is envisaged that the volumetric data capacity, long term stability and low maintenance characteristics demonstrated will have major benefits in increasing reliability and reducing the costs associated with archival storage of large data volumes.

  5. Accuracy testing of electric groundwater-level measurement tapes

    USGS Publications Warehouse

    Jelinski, Jim; Clayton, Christopher S.; Fulford, Janice M.

    2015-01-01

    The accuracy tests demonstrated that none of the electric-tape models tested consistently met the suggested USGS accuracy of ±0.01 ft. The test data show that the tape models in the study should give a water-level measurement that is accurate to roughly ±0.05 ft per 100 ft without additional calibration. To meet USGS accuracy guidelines, the electric-tape models tested will need to be individually calibrated. Specific conductance also plays a part in tape accuracy. The probes will not work in water with specific conductance values near zero, and the accuracy of one probe was unreliable in very high conductivity water (10,000 microsiemens per centimeter).

  6. VIEW OF CABLES AND TAPES ASSOCIATED WITH ADRIVE CONTROL ROD ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    VIEW OF CABLES AND TAPES ASSOCIATED WITH A-DRIVE CONTROL ROD SYSTEM, AT LEVEL +15’, DIRECTLY ABOVE PDP CONTROL ROOM, LOOKING NORTH - Physics Assembly Laboratory, Area A/M, Savannah River Site, Aiken, Aiken County, SC

  7. On aluminum tapes treated for missions at Jupiter

    NASA Astrophysics Data System (ADS)

    Montero, I.; Sanmartin, Jr.

    2017-09-01

    In this work we present treatment of aluminum surface to raise its termal emissivity to values around 0.7 while keeping its high electrical conductivity, as required for tape tethers missions at Júpiter.

  8. Vaginal estrogen: a dual-edged sword in postoperative healing of the vaginal wall.

    PubMed

    Ripperda, Christopher M; Maldonado, Pedro Antonio; Acevedo, Jesus F; Keller, Patrick W; Akgul, Yucel; Shelton, John M; Word, Ruth Ann

    2017-07-01

    Reconstructive surgery for pelvic organ prolapse is plagued with high failure rates possibly due to impaired healing or regeneration of the vaginal wall. Here, we tested the hypothesis that postoperative administration of local estrogen, direct injection of mesenchymal stem cells (MSCs), or both lead to improved wound healing of the injured vagina in a menopausal rat model. Ovariectomized rats underwent surgical injury to the posterior vaginal wall and were randomized to treatment with placebo (n = 41), estrogen cream (n = 47), direct injection of MSCs (n = 39), or both (n = 43). MSCs did not survive after injection and had no appreciable effects on healing of the vaginal wall. Acute postoperative administration of vaginal estrogen altered the response of the vaginal wall to injury with decreased stiffness, decreased collagen content, and decreased expression of transcripts for matrix components in the stromal compartment. Conversely, vaginal estrogen resulted in marked proliferation of the epithelial layer and increased expression of genes related to epithelial barrier function and protease inhibition. Transcripts for genes involved in chronic inflammation and adaptive immunity were also down-regulated in the estrogenized epithelium. Collectively, these data indicate that, in contrast to the reported positive effects of preoperative estrogen on the uninjured vagina, acute administration of postoperative vaginal estrogen has adverse effects on the early phase of healing of the stromal layer. In contrast, postoperative estrogen plays a positive role in healing of the vaginal epithelium after injury.

  9. Vaginal estrogen: a dual-edged sword in postoperative healing of the vaginal wall

    PubMed Central

    Ripperda, Christopher M.; Maldonado, Pedro Antonio; Acevedo, Jesus F.; Keller, Patrick W.; Akgul, Yucel; Shelton, John M.; Word, Ruth Ann

    2017-01-01

    Abstract Objective: Reconstructive surgery for pelvic organ prolapse is plagued with high failure rates possibly due to impaired healing or regeneration of the vaginal wall. Here, we tested the hypothesis that postoperative administration of local estrogen, direct injection of mesenchymal stem cells (MSCs), or both lead to improved wound healing of the injured vagina in a menopausal rat model. Methods: Ovariectomized rats underwent surgical injury to the posterior vaginal wall and were randomized to treatment with placebo (n = 41), estrogen cream (n = 47), direct injection of MSCs (n = 39), or both (n = 43). Results: MSCs did not survive after injection and had no appreciable effects on healing of the vaginal wall. Acute postoperative administration of vaginal estrogen altered the response of the vaginal wall to injury with decreased stiffness, decreased collagen content, and decreased expression of transcripts for matrix components in the stromal compartment. Conversely, vaginal estrogen resulted in marked proliferation of the epithelial layer and increased expression of genes related to epithelial barrier function and protease inhibition. Transcripts for genes involved in chronic inflammation and adaptive immunity were also down-regulated in the estrogenized epithelium. Conclusions: Collectively, these data indicate that, in contrast to the reported positive effects of preoperative estrogen on the uninjured vagina, acute administration of postoperative vaginal estrogen has adverse effects on the early phase of healing of the stromal layer. In contrast, postoperative estrogen plays a positive role in healing of the vaginal epithelium after injury. PMID:28169915

  10. DICOM implementation on online tape library storage system

    NASA Astrophysics Data System (ADS)

    Komo, Darmadi; Dai, Hailei L.; Elghammer, David; Levine, Betty A.; Mun, Seong K.

    1998-07-01

    The main purpose of this project is to implement a Digital Image and Communications (DICOM) compliant online tape library system over the Internet. Once finished, the system will be used to store medical exams generated from U.S. ARMY Mobile ARMY Surgical Hospital (MASH) in Tuzla, Bosnia. A modified UC Davis implementation of DICOM storage class is used for this project. DICOM storage class user and provider are implemented as the system's interface to the Internet. The DICOM software provides flexible configuration options such as types of modalities and trusted remote DICOM hosts. Metadata is extracted from each exam and indexed in a relational database for query and retrieve purposes. The medical images are stored inside the Wolfcreek-9360 tape library system from StorageTek Corporation. The tape library system has nearline access to more than 1000 tapes. Each tape has a capacity of 800 megabytes making the total nearline tape access of around 1 terabyte. The tape library uses the Application Storage Manager (ASM) which provides cost-effective file management, storage, archival, and retrieval services. ASM automatically and transparently copies files from expensive magnetic disk to less expensive nearline tape library, and restores the files back when they are needed. The ASM also provides a crash recovery tool, which enable an entire file system restore in a short time. A graphical user interface (GUI) function is used to view the contents of the storage systems. This GUI also allows user to retrieve the stored exams and send the exams to anywhere on the Internet using DICOM protocols. With the integration of different components of the system, we have implemented a high capacity online tape library storage system that is flexible and easy to use. Using tape as an alternative storage media as opposed to the magnetic disk has the great potential of cost savings in terms of dollars per megabyte of storage. As this system matures, the Hospital Information Systems

  11. Gait Kinematics After Taping in Participants With Chronic Ankle Instability

    PubMed Central

    Chinn, Lisa; Dicharry, Jay; Hart, Joseph M.; Saliba, Susan; Wilder, Robert; Hertel, Jay

    2014-01-01

    Context: Chronic ankle instability is characterized by repetitive lateral ankle sprains. Prophylactic ankle taping is a common intervention used to reduce the risk of ankle sprains. However, little research has been conducted to evaluate the effect ankle taping has on gait kinematics. Objective: To investigate the effect of taping on ankle and knee kinematics during walking and jogging in participants with chronic ankle instability. Design: Controlled laboratory study. Setting: Motion analysis laboratory. Patients or Participants: A total of 15 individuals (8 men, 7 women; age = 26.9 ± 6.8 years, height = 171.7 ± 6.3 cm, mass = 73.5 ± 10.7 kg) with self-reported chronic ankle instability volunteered. They had an average of 5.3 ± 3.1 incidences of ankle sprain. Intervention(s): Participants walked and jogged in shoes on a treadmill while untaped and taped. The tape technique was a traditional preventive taping procedure. Conditions were randomized. Main Outcome Measure(s): Frontal-plane and sagittal-plane ankle and sagittal-plane knee kinematics were recorded throughout the entire gait cycle. Group means and 90% confidence intervals were calculated, plotted, and inspected for percentages of the gait cycle in which the confidence intervals did not overlap. Results: During walking, participants were less plantar flexed from 64% to 69% of the gait cycle (mean difference = 5.73° ± 0.54°) and less inverted from 51% to 61% (mean difference = 4.34° ± 0.65°) and 76% to 81% (mean difference = 5.55° ± 0.54°) of the gait cycle when taped. During jogging, participants were less dorsiflexed from 12% to 21% (mean difference = 4.91° ± 0.18°) and less inverted from 47% to 58% (mean difference = 6.52° ± 0.12°) of the gait cycle when taped. No sagittal-plane knee kinematic differences were found. Conclusions: In those with chronic ankle instability, taping resulted in a more neutral ankle position during walking and jogging in shoes on a treadmill. This change in

  12. Apical and root canal space sealing abilities of resin and glass ionomer-based root canal obturation systems.

    PubMed

    Royer, Kinga; Liu, Xue Jun; Zhu, Qiang; Malmstrom, Hans; Ren, Yan-Fang

    2013-01-01

    To investigate the apical sealing ability of glass ionomer and resin-based root canal obturation systems in comparison to a conventional vertical compaction of warm guttapercha. Forty-five extracted human teeth were randomly assigned into 3 groups of 15 each: a resin-based (EndoRez), a glass ionomer-based (Activ GP), and a conventional gutta-percha plus pulp sealer obturation system (GP/EWT). Apical and root canal space sealing abilities were assessed on five cross-sections 1.0 mm apart starting from the apex. Cross-section images were analysed using a focus-variation 3D scanning microscope and unsealed space was calculated as the percentage of total root canal space occupied by voids and debris. EndoRez had significantly higher rate of apical leakage and deeper dye penetration as compared to GP/EWT and Activ GP. EndoRez group had also more voids and debris (22.5%) in the root canal spaces as compared to GP/EWT (10.5%) and Activ GP (10.8%). Apical leakages occurred not only along the root canal walls, but also along the gutta-percha cones with EndoRez as a result of significant polymerisation shrinkage of the resin sealer. Resin-based EndoRez did not form an adequate apical seal of filled root canals. Glass ionomer-based Activ GP was comparable to a vertical compaction of warm guttapercha plus EWT sealer in sealing root canal spaces.

  13. An in vitro comparative study of the adaptation and sealing ability of two carrier-based root canal obturators.

    PubMed

    Alkahtani, Ahmed; Al-Subait, Sara; Anil, Sukumaran

    2013-01-01

    The study was done to assess the sealing ability and adaptation of RealSeal 1, and to compare it with Thermafil. 65 single-rooted extracted teeth were selected and root canal treatment was performed. Root canals were obturated with RealSeal 1 or Thermafil. A double chamber bacterial leakage model using E. faecalis was developed to assess the sealing ability. Samples were monitored daily for 60 days. After the bacterial leakage test, samples were embedded in resin and sectioned horizontally at 2 and 4 mm from the apical foramen. Specimens were examined under scanning electron microscope and digitally photographed. AutoCAD software was used to measure the gap between the canal surface and obturation material. Results were statistically analyzed using nonparametric Kaplan-Meier survival analysis for the bacterial leakage and t-test to compare the means of gap in RealSeal 1 and Thermafil at 2 and 4 mm. There was no significant difference between the RealSeal 1 and Thermafil with respect to leakage over time. At 2 mm and 4 mm, RealSeal 1 had significantly more gaps than Thermafil. From the observations it can be concluded that RealSeal 1 and Thermafil have comparable performance in terms of adaptation and sealing ability.

  14. An In Vitro Comparative Study of the Adaptation and Sealing Ability of Two Carrier-Based Root Canal Obturators

    PubMed Central

    Alkahtani, Ahmed; Al-Subait, Sara; Anil, Sukumaran

    2013-01-01

    The study was done to assess the sealing ability and adaptation of RealSeal 1, and to compare it with Thermafil. 65 single-rooted extracted teeth were selected and root canal treatment was performed. Root canals were obturated with RealSeal 1 or Thermafil. A double chamber bacterial leakage model using E. faecalis was developed to assess the sealing ability. Samples were monitored daily for 60 days. After the bacterial leakage test, samples were embedded in resin and sectioned horizontally at 2 and 4 mm from the apical foramen. Specimens were examined under scanning electron microscope and digitally photographed. AutoCAD software was used to measure the gap between the canal surface and obturation material. Results were statistically analyzed using nonparametric Kaplan-Meier survival analysis for the bacterial leakage and t-test to compare the means of gap in RealSeal 1 and Thermafil at 2 and 4 mm. There was no significant difference between the RealSeal 1 and Thermafil with respect to leakage over time. At 2 mm and 4 mm, RealSeal 1 had significantly more gaps than Thermafil. From the observations it can be concluded that RealSeal 1 and Thermafil have comparable performance in terms of adaptation and sealing ability. PMID:23710141

  15. Storage, Preservation, and Recovery of Magnetic Recording Tape

    NASA Technical Reports Server (NTRS)

    Cuddihy, Edward F.

    1994-01-01

    During the 1970's, a commercial magnetic recording tape fabricated with magnetic oxide particles, and with oxide and backcoat binders made from polyester urethane was being used for spacecraft tape recorders, and which would periodically manifest operational problems such as layer-to-layer adhesion, stick-slip, and shedding of sticky organic materials. These problems were generally associated with periods of high humidity. An experimental study identified that these problems resulted from hydrolysis of the polyester urethane binders.

  16. Synchronisation Technique of Data Recorded on a Multichannel Tape Recorder,

    DTIC Science & Technology

    1984-01-01

    retrieval Synchronizers I 16. Abstract A portable, self-contained, electronic digital unit, termed Data Synchroniser was designed and developed by EDE...AD A139 570 SYNCHRONISATION TECHNIQUE OF DATA RECORDED ON A / OULl ICHANNEL TAPE RECORDER (U) ENGINEERING DEVELOPMENT ESTA B LISHMENT MARIBYRNONO...BGINEERING DEVELOPMEWIT ESTABUSHIMENT S[ SYNCHRONISATION TECHNIQUE OF DATA - i RECORDED ON A MULTICHANNEL TAPE RECORDER BY J.D. DICKENS .t T)TCi j.D. ~c .s

  17. VIEW OF CABLES AND TAPES ASSOCIATED WITH ADRIVE CONTROL ROD ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    VIEW OF CABLES AND TAPES ASSOCIATED WITH A-DRIVE CONTROL ROD SYSTEM, AT LEVEL +15’, DIRECTLY ABOVE PDP CONTROL ROOM, LOOKING NORTHWEST. THE CABLES FROM THE PDP ROOM GO THROUGH THE CONCRETE WALL, MAKE A RIGHT ANGLE TURN DOWNWARD, AND DESCEND INTO THE PDP CONTROL ROOM AS VERTICAL TAPES - Physics Assembly Laboratory, Area A/M, Savannah River Site, Aiken, Aiken County, SC

  18. Semaphorin 4D induces vaginal epithelial cell apoptosis to control mouse postnatal vaginal tissue remodeling.

    PubMed

    Ito, Takuji; Bai, Tao; Tanaka, Tetsuji; Yoshida, Kenji; Ueyama, Takashi; Miyajima, Masayasu; Negishi, Takayuki; Kawasaki, Takahiko; Takamatsu, Hyota; Kikutani, Hitoshi; Kumanogoh, Atsushi; Yukawa, Kazunori

    2015-02-01

    The opening of the mouse vaginal cavity to the skin is a postnatal tissue remodeling process that occurs at approximately five weeks of age for the completion of female genital tract maturation at puberty. The tissue remodeling process is primarily composed of a hormonally triggered apoptotic process predominantly occurring in the epithelium of the distal section of the vaginal cavity. However, the detailed mechanism underlying the apoptotic induction remains to be elucidated. In the present study, it was observed that the majority of BALB/c mice lacking the class 4 semaphorin, semaphorin 4D (Sema4D), developed imperforate vagina and hydrometrocolpos resulting in a perpetually unopened vaginal cavity regardless of a normal estrogen level comparable with that in wild‑type (WT) mice. Administration of β‑estradiol to infant Sema4D‑deficient (Sema4D‑/‑) mice did not induce precocious vaginal opening, which was observed in WT mice subjected to the same β‑estradiol administration, excluding the possibility that the closed vaginal phenotype was due to insufficient estrogen secretion at the time of vaginal opening. In order to assess the role of Sema4D in the postnatal vaginal tissue remodeling process, the expression of Sema4D and its receptor, plexin‑B1, was examined as well as the level of apoptosis in the vaginal epithelia of five‑week‑old WT and Sema4D‑/‑ mice. Immunohistochemical analyses confirmed the localization of Sema4D and plexin‑B1 in the mouse vaginal epithelia. Terminal deoxynucleotidyl transferase dUTP nick end labeling assay and immunohistochemistry detecting activated caspase‑3 revealed significantly fewer apoptotic cells in situ in the vaginal mucosa of five‑week‑old Sema4D‑/‑ mice compared with WT mice. The addition of recombinant Sema4D to Sema4D‑/‑ vaginal epithelial cells in culture significantly enhanced apoptosis of the vaginal epithelial cells, demonstrating the apoptosis‑inducing activity of Sema4D. The

  19. Semaphorin 4D induces vaginal epithelial cell apoptosis to control mouse postnatal vaginal tissue remodeling

    PubMed Central

    ITO, TAKUJI; BAI, TAO; TANAKA, TETSUJI; YOSHIDA, KENJI; UEYAMA, TAKASHI; MIYAJIMA, MASAYASU; NEGISHI, TAKAYUKI; KAWASAKI, TAKAHIKO; TAKAMATSU, HYOTA; KIKUTANI, HITOSHI; KUMANOGOH, ATSUSHI; YUKAWA, KAZUNORI

    2015-01-01

    The opening of the mouse vaginal cavity to the skin is a postnatal tissue remodeling process that occurs at approximately five weeks of age for the completion of female genital tract maturation at puberty. The tissue remodeling process is primarily composed of a hormonally triggered apoptotic process predominantly occurring in the epithelium of the distal section of the vaginal cavity. However, the detailed mechanism underlying the apoptotic induction remains to be elucidated. In the present study, it was observed that the majority of BALB/c mice lacking the class 4 semaphorin, semaphorin 4D (Sema4D), developed imperforate vagina and hydrometrocolpos resulting in a perpetually unopened vaginal cavity regardless of a normal estrogen level comparable with that in wild-type (WT) mice. Administration of β-estradiol to infant Sema4D-deficient (Sema4D−/−) mice did not induce precocious vaginal opening, which was observed in WT mice subjected to the same β-estradiol administration, excluding the possibility that the closed vaginal phenotype was due to insufficient estrogen secretion at the time of vaginal opening. In order to assess the role of Sema4D in the postnatal vaginal tissue remodeling process, the expression of Sema4D and its receptor, plexin-B1, was examined as well as the level of apoptosis in the vaginal epithelia of five-week-old WT and Sema4D−/− mice. Immunohistochemical analyses confirmed the localization of Sema4D and plexin-B1 in the mouse vaginal epithelia. Terminal deoxynucleotidyl transferase dUTP nick end labeling assay and immunohistochemistry detecting activated caspase-3 revealed significantly fewer apoptotic cells in situ in the vaginal mucosa of five-week-old Sema4D−/− mice compared with WT mice. The addition of recombinant Sema4D to Sema4D−/− vaginal epithelial cells in culture significantly enhanced apoptosis of the vaginal epithelial cells, demonstrating the apoptosis-inducing activity of Sema4D. The experimental reduction of

  20. Innovative non-surgical management of pelvic and anterior vaginal wall abscess following vaginal surgery.

    PubMed

    Singh, Nisha; Negi, Neha; Kumar, Namrata

    2016-08-29

    Surgical site infections remain a common cause of morbidity following gynaecological surgery. The widespread implementation of antibiotic prophylaxis prior to surgery, as well as cognizance of modifiable risk factors for postoperative infection, has led to a significant reduction in postoperative infection rates. However, in low resource settings where sepsis and infections are common, surgical site infections following vaginal hysterectomy are sometimes encountered. It is a challenge to treat these infections with minimal intervention avoiding repeat surgery. We report here a unique situation following vaginal hysterectomy and then laparotomy; where a pelvic abscess communicated with the vesicovaginal space and drained through an opening into the anterior vaginal wall. An innovative technique was used to drain this anterior vaginal wall abscess connecting to pelvic cavity using a 40 cm long disposable urinary catheter (made of polyvinyl chloride), which was inserted into the vaginal opening under ultrasound guidance. 2016 BMJ Publishing Group Ltd.

  1. [Sulphurous vaginal douching and vulvovaginal atrophy].

    PubMed

    Costantino, M; Conti, V; Marongiu, M B; Napolano, G; Filippelli, A

    2017-01-01

    During climacteric the reduction or interruption of estrogenic stimulus determines a gradual atrophy of the tissues of the urogenital tract.Vulvovaginal atrophy can be cause of dryness, itch, burning, and dyspareunia. Vulvovaginal atrophy is associated also with depression. Hence the importance of an appropriate treatment of the vulvovaginal atrophy. Between therapeutic options we can add, particularly for women who suffer only from vaginal symptoms, the spa therapy that uses mineral waters with benefic effects on vaginal tissue wellness and health. On the basis of considerations described above and on the insufficient literature data, the objective of our single-arm pilot study has been to evaluate, in women suffering from vulvovaginal atrophy, the effects and safety of a vaginal douching cycle with sulphurous mineral water and impact on depression disorder frequently observed. The study was conducted on 24 women affected by vulvovaginal atrophy; mean age:57±11 years; age range:42-81 years. The subjects were treated, for 2 weeks, with sulphurous vaginal douching from Terme of Telese S.p.A. (Benevento-Italy). At the beginning and at the end of the SPA treatment the following symptoms were evaluated: dryness, burning, itch, dyspareunia and leucorrhoea (using VAS scale); the impact on psychological distress (using S.D.S. Zung-test). At the end of the spa treatment, the mean values±SD, compared to baseline, have showed a significant (p<0.05) reduction in leucorrhoea (-88%), in vulvar itch (-79%), in vaginal burning (-71%), in vaginal dryness (-65%) with an improvement of psichological distress as demonstrated by S.D.S. Zung-test. The data of this single-arm pilot clinical trial show that the sulphurous vaginal douching cycle can be considered very useful in women suffering from vulvovaginal atrophy with improving of the quality of life and social relationship.

  2. TVT-Secur (Hammock) Versus TVT-Obturator: A Randomized Trial of Suburethral Sling Operative Procedures

    PubMed Central

    Hota, Lekha S.; Hanaway, Katherine; Hacker, Michele R.; Disciullo, Anthony; Elkadry, Eman; Dramitinos, Patricia; Shapiro, Alexander; Ferzandi, Tanaz; Rosenblatt, Peter L.

    2013-01-01

    Objectives This study aimed to compare TVT-Secur (TVT-S) and TVT-Obturator (TVT-O) suburethral slings for treatment of stress urinary incontinence (SUI). Methods This was a single-center, nonblinded, randomized trial of women with SUI who were randomized to TVT-S or TVT-O from May 2007 to April 2009. The primary outcome, SUI on cough stress test (CST), and quality-of-life and symptom questionnaires (Pelvic Floor Distress Inventory [PFDI-20] and Pelvic Floor Impact Questionnaire [PFIQ-7]) were assessed at 12 weeks and 1 year. Results Forty-three women were randomized to TVT-S and 44 to TVT-O. There were no differences in median baseline PFDI-20 and PFIQ-7. Twenty-two (52.4%) of 42 participants randomized to TVT-S had a positive CST result at evaluation after 12 weeks or 1 year, whereas 4 (9.1%) of the 44 in the TVT-O group had a positive CST result. The intent-to-treat analysis showed that the risk of a positive CST result was 6 times higher after TVT-S than TVT-O (risk ratio, 6.0; 95% confidence interval [CI], 2.3–16.0). Among women not lost to follow-up, the risk ratio for a positive CST result after TVT-S compared with TVT-O was 17.9 (95% CI, 2.5–128.0) at 12 weeks and 3.5 (95% CI, 1.1–11.0) at 1 year. Both TVT-S and TVT-O resulted in improved quality of life and symptoms at 12 weeks. There was no difference between the groups for PFDI-20 (P = 0.40) or PFIQ-7 (P = 0.43). A similar pattern was seen at 1 year (P = 0.85 and P = 0.36). Conclusions The TVT-S seems to have a higher risk of positive postoperative CST result; however, the procedures result in similar improvements in quality of life and symptoms. PMID:22453267

  3. TVT-Secur (Hammock) versus TVT-Obturator: a randomized trial of suburethral sling operative procedures.

    PubMed

    Hota, Lekha S; Hanaway, Katherine; Hacker, Michele R; Disciullo, Anthony; Elkadry, Eman; Dramitinos, Patricia; Shapiro, Alexander; Ferzandi, Tanaz; Rosenblatt, Peter L

    2012-01-01

    This study aimed to compare TVT-Secur (TVT-S) and TVT-Obturator (TVT-O) suburethral slings for treatment of stress urinary incontinence (SUI). This was a single-center, nonblinded, randomized trial of women with SUI who were randomized to TVT-S or TVT-O from May 2007 to April 2009. The primary outcome, SUI on cough stress test (CST), and quality-of-life and symptom questionnaires (Pelvic Floor Distress Inventory [PFDI-20] and Pelvic Floor Impact Questionnaire [PFIQ-7]) were assessed at 12 weeks and 1 year. Forty-three women were randomized to TVT-S and 44 to TVT-O. There were no differences in median baseline PFDI-20 and PFIQ-7. Twenty-two (52.4%) of 42 participants randomized to TVT-S had a positive CST result at evaluation after 12 weeks or 1 year, whereas 4 (9.1%) of the 44 in the TVT-O group had a positive CST result. The intent-to-treat analysis showed that the risk of a positive CST result was 6 times higher after TVT-S than TVT-O (risk ratio, 6.0; 95% confidence interval [CI], 2.3-16.0). Among women not lost to follow-up, the risk ratio for a positive CST result after TVT-S compared with TVT-O was 17.9 (95% CI, 2.5-128.0) at 12 weeks and 3.5 (95% CI, 1.1-11.0) at 1 year. Both TVT-S and TVT-O resulted in improved quality of life and symptoms at 12 weeks. There was no difference between the groups for PFDI-20 (P = 0.40) or PFIQ-7 (P = 0.43). A similar pattern was seen at 1 year (P = 0.85 and P = 0.36). The TVT-S seems to have a higher risk of positive postoperative CST result; however, the procedures result in similar improvements in quality of life and symptoms.

  4. Calibration tests on magnetic tape lightning current detectors

    NASA Technical Reports Server (NTRS)

    Crouch, K. E.

    1980-01-01

    The low cost, passive, peak lightning current detector (LCD) invented at the NASA/Kennedy Space Center, uses magnetic audio recording tape to sense the magnitude of the peak magnetic field around a conductor carrying lightning currents. Test results show that the length of audio tape erased was linearly related to the peak simulated lightning currents in a round conductor. Accuracies of + or - 10% were shown for measurements made using a stopwatch readout technique to determine the amount of tape erased by the lightning current. The stopwatch technique is a simple, low cost means of obtaining LCD readouts and can be used in the field to obtain immediate results. Where more accurate data are desired, the tape is played and the output recorded on a strip chart, oscilloscope, or some other means so that measurements can be made on that recording. Conductor dimensions, tape holder dimensions, and tape formulation must also be considered to obtain a more accurate result. If the shape of the conductor is other than circular (i.e., angle, channel, H-beam), an analysis of the magnetic field is required to use an LCD, especially at low current levels.

  5. Effects of Kinesio taping and exercise on forward head posture.

    PubMed

    Shih, Hsu-Sheng; Chen, Shu-Shi; Cheng, Su-Chun; Chang, Hsun-Wen; Wu, Pei-Rong; Yang, Jin-Shiou; Lee, Yi-Shuang; Tsou, Jui-Yi

    2017-01-01

    Little is known about the effects of Kinesio taping and therapeutic exercise on correcting forward head posture. To compare Kinesio taping versus therapeutic exercise for forward head posture on static posture, dynamic mobility and functional outcomes. Sixty subjects (31 women, 29 men) with forward head postures participated in this study. They were randomly assigned to either one of the three groups: (1) exercise group (n = 20), (2) taping group (n = 20), and (3) control groups (n = 20). The horizontal forward displacement (HFD) between ear lobe and acromion process, upper cervical and lower cervical angle (UCA, LCA), active range of motion (AROM) of cervical spine, and neck disability index (NDI) were measured before and after a 5-week intervention, and a 2-week follow-up. Data were analyzed by means of a mixed design repeated-measures ANOVA. Both taping and exercise groups showed significant improvements in HFD compared with the control group at post-treatment and follow-up. Compared with the control group, the exercise group exhibited significant improvements in the LCA and the side bending AROM at post-treatment. Both Kinesio taping and therapeutic exercise improve forward head posture after intervention and a 2-week follow-up. The effectiveness of therapeutic exercise is better than taping.

  6. Kinesio Taping effects on knee extension force among soccer players

    PubMed Central

    Serra, Maysa V. G. B.; Vieira, Edgar R.; Brunt, Denis; Goethel, Márcio F.; Gonçalves, Mauro; Quemelo, Paulo R. V.

    2015-01-01

    Background: Kinesio Taping (KT) is widely used, however the effects of KT on muscle activation and force are contradictory. Objective: To evaluate the effects of KT on knee extension force in soccer players. Method: This is a clinical trial study design. Thirty-four subjects performed two maximal isometric voluntary contractions of the lower limbs pre, immediately post, and 24 hours after tape application on the lower limbs. Both lower limbs were taped, using K-Tape and 3M Micropore tape randomly on the right and left thighs of the participants. Isometric knee extension force was measured for dominant side using a strain gauge. The following variables were assessed: peak force, time to peak force, rate of force development until peak force, time to peak rate of force development, and 200 ms pulse. Results: There were no statistically significant differences in the variables assessed between KT and Micropore conditions (F=0.645, p=0.666) or among testing sessions (pre, post, and 24h after) (F=0.528, p=0.868), and there was no statistical significance (F=0.271, p=0.986) for interaction between tape conditions and testing session. Conclusion: KT did not affect the force-related measures assessed immediately and 24 hours after the KT application compared with Micropore application, during maximal isometric voluntary knee extension. PMID:25789557

  7. Kinesio Taping effects on knee extension force among soccer players.

    PubMed

    Serra, Maysa V G B; Vieira, Edgar R; Brunt, Denis; Goethel, Márcio F; Gonçalves, Mauro; Quemelo, Paulo R V

    2015-01-01

    Kinesio Taping (KT) is widely used, however the effects of KT on muscle activation and force are contradictory. To evaluate the effects of KT on knee extension force in soccer players. This is a clinical trial study design. Thirty-four subjects performed two maximal isometric voluntary contractions of the lower limbs pre, immediately post, and 24 hours after tape application on the lower limbs. Both lower limbs were taped, using K-Tape and 3M Micropore tape randomly on the right and left thighs of the participants. Isometric knee extension force was measured for dominant side using a strain gauge. The following variables were assessed: peak force, time to peak force, rate of force development until peak force, time to peak rate of force development, and 200 ms pulse. There were no statistically significant differences in the variables assessed between KT and Micropore conditions (F=0.645, p=0.666) or among testing sessions (pre, post, and 24h after) (F=0.528, p=0.868), and there was no statistical significance (F=0.271, p=0.986) for interaction between tape conditions and testing session. KT did not affect the force-related measures assessed immediately and 24 hours after the KT application compared with Micropore application, during maximal isometric voluntary knee extension.

  8. Ontario children have outgrown the Broselow tape.

    PubMed

    Milne, William Ken; Yasin, Abeer; Knight, Janine; Noel, Daniel; Lubell, Richard; Filler, Guido

    2012-01-01

    The Broselow Pediatric Emergency Tape (Armstrong Medical Industries, Inc., Lincolnshire, IL) (BT) is a well-established length-based tool for estimation of body weight for children during resuscitation. In view of pandemic childhood obesity, the BT may no longer accurately estimate weight. We therefore studied the BT in children from Ontario in a large recent patient cohort. Actual height and weight were obtained from an urban and a rural setting. Children were prospectively recruited between April 2007 and July 2008 from the emergency department and outpatient clinics at the London Health Science Centre. Rural children from junior kindergarten to grade 4 were also recruited in the spring of 2008 from the Avon Maitland District School Board. Data for preschool children were obtained from three daycare centres and the electronic medical record from the Maitland Valley Medical Centre. The predicted weight from the BT was compared to the actual weight using Spearman rank correlation; agreement and percent error (PE) were also calculated. A total of 6,361 children (46.2% female) were included in the study. The median age was 3.9 years (interquartile range [IQR] 1.56-7.67 years), weight was 17.2 kg (IQR 11.6-25.4 kg), and height was 103.5 cm (IQR 82-124.4 cm). Although the BT weight estimate correlated with the actual weight (r  =  0.95577, p < 0.0001), the BT underestimated the actual weight by 1.62 kg (7.1% ± 16.9% SD, 95% CI -26.0-40.2). The BT had an ≥ 10% PE 43.7% of the time. Although the BT remains an effective method for estimating pediatric weight, it was not accurate and tended to underestimate the weight of Ontario children. Until more accurate measurement tools for emergency departments are developed, physicians should be aware of this discrepancy.

  9. A new method of measurement of tension on a moving magnetic tape

    NASA Technical Reports Server (NTRS)

    Kurtinaytis, A. K.; Lauzhinskas, Y. S.

    1973-01-01

    The possibility of no-contact measurement of the tension on a moving magnetic tape, assuming the tape is uniform, is discussed. A scheme for calculation of the natural frequency of transverse vibrations of magnetic tape is shown. Mathematical models are developed to show the relationships of the parameters. The method is applicable to the analysis of accurate tape feed mechanisms design.

  10. Generation and physical characteristics of the ERTS MSS system corrected computer compatible tapes

    NASA Technical Reports Server (NTRS)

    Thomas, V. L.

    1973-01-01

    The generation and format are discussed of the ERTS system corrected multispectral scanner computer compatible tapes. The discussion includes spacecraft sensors, scene characteristics, data transmission, and conversion of data to computer compatible tapes at the NASA Data Processing Facility. Geometeric and radiometric corrections, tape formats, and the physical characteristics of the tapes are also included.

  11. Generation and physical characteristics of the LANDSAT-1, -2 and -3 MSS computer compatible tapes

    NASA Technical Reports Server (NTRS)

    Thomas, V. L.

    1977-01-01

    The generation and format of the LANDSAT 1, 2, and 3 system corrected multispectral scanner computer compatible tapes are discussed. Included in the discussion are the spacecraft sensors, scene characteristics, the transmission of data, and the conversion of the data to computer compatible tapes. Also included in the discussion are geometric and radiometric corrections, tape formats, and the physical characteristics of the tape.

  12. Immediate Effects of Ankle Balance Taping with Kinesiology Tape for Amateur Soccer Players with Lateral Ankle Sprain: A Randomized Cross-Over Design

    PubMed Central

    Kim, Myoung Kwon; Shin, Young Jun

    2017-01-01

    Background The objective of this study was to investigate the immediate effect on gait function when ankle balance taping is applied to amateur soccer players with lateral ankle sprain. Material/Methods A cross-over randomized design was used. Twenty-two soccer players with an ankle sprain underwent 3 interventions in a random order. Subjects were randomly assigned to ankle balance taping, placebo taping, and no taping groups. The assessment was performed using the GAITRite portable walkway system, which records the location and timing of each footfall during ambulation. Results Significant differences were found in the velocity, step length, stride length, and H-H base support among the 3 different taping methods (p<0.05). The ankle balance taping group showed significantly greater velocity, step length, and stride length in comparison to the placebo and no taping group. The ankle balance taping group showed a statistically significant decrease (p<0.05) in the H-H base support compared to the placebo and no taping groups, and the placebo group showed significantly greater velocity in comparison to the no taping group (p<0.05). Conclusions We conclude that ankle balance taping that uses kinesiology tape instantly increased the walking ability of amateur soccer players with lateral ankle sprain. Therefore, ankle balance taping is a useful alternative to prevent and treat ankle sprain of soccer players. PMID:29158472

  13. Aerobic vaginal pathogens and their sensitivity pattern.

    PubMed

    Mumtaz, Shamim; Ahmad, Mumtaz; Aftab, Irum; Akhtar, Naeem; ul Hassan, Masood; Hamid, Abdul

    2008-01-01

    The vaginal flora is a complicated environment, containing dozens of microbiological species in variable quantities and relative proportions. The frequent cause of vaginal discharge is an infection or colonization with different microorganisms. Some pathologic conditions causing vaginitis are well defined yet, 7-72% of women with vaginitis may remain undiagnosed and such forms of abnormal vaginal flora neither considered as normal, nor can be called bacterial vaginosis have been termed as 'intermediate flora' and its management probably differ from that of bacterial vaginosis. It is of crucial importance in pregnant females at risk of preterm delivery. The present study has been conducted especially to elucidate this type of aerobic vaginal isolates and their culture and sensitivity towards currently used antibiotics. This study was conducted at the Microbiology Department of Fauji Foundation Hospital, Rawalpindi over a period of two years (April 2004-March 2006). One thousand, nine hundred and twenty three high vaginal swabs, both from indoor and outdoor patients were collected, cultured and their susceptibility to various antibiotics was determined. Significant growth was obtained in 731 samples. The highest frequency of infection (39.5%) was observed at 31-40 years followed by 41-50 years (35.8%). About 76% were from outdoor and 24% were from indoor patients. Staphylococcus aureus was the most prevalent vaginal pathogen at 11-60 yrs & with highest prevalence at 31-40 years followed by 41-50 years. It was a predominant pathogen in both indoor (35%) as well as outdoor (41.6%) patients, followed by enteric gram-negative bacilli and other gram-positive cocci. There were very few antibiotics among the conventionally available aminoglycosides, third generation cephalosporins, penicillin, quinolones, sulfonamides and tetracyclines possessing good sensitivity (> 80%) against any one the common aerobic vaginal pathogens. The effective chemotherapeutics agents belong to

  14. Obituary: Gerald Frederick Tape, 1915-2005

    NASA Astrophysics Data System (ADS)

    Hughes, Robert E.

    2007-12-01

    Gerald Frederick Tape, a distinguished science statesman and administrator, died on November 20, 2005. Jerry, as he was known to all, took on many diverse and important responsibilities throughout his life and dealt with them with quiet authority and grace. This was the hallmark of his life. The Board of Trustees of Associated Universities, Inc., which he served for many years, expressed this in its condolences, writing "Jerry personified integrity, thoroughness and dedication. His sensitivity for the views of others, his sincerity, his personal commitment, his calm approach and his unfailing good humor were all greatly admired and respected." Jerry was born in Ann Arbor, Michigan on May 29, 1915 but grew up in Milan, a nearby country farm community, and in Ypsilanti where his father was Principal of Michigan State Normal College, which later became Eastern Michigan University (EMU). It was there that he first became interested in physics. It was there also that he met and courted Josephine Waffen, who later would become his wife for more than sixty-six years and fill their lives with three loving sons, Walter, James, and Thomas. Upon graduation from EMU, Jerry was awarded a scholarship that took him to the University of Michigan where he earned a Ph.D. in Physics, researching the decay modes of the radioisotopes of iodine. In the Fall of 1939, during the waning days of the Great Depression, he was offered an Instructorship in the Physics Department of Cornell University, a promising start for a fruitful academic career. He brought his bride Jo to Ithaca and joined the cyclotron group under Robert Bacher and Willy Higginbotham while devising a laboratory course in nuclear techniques for graduate students. Bacher and Higginbotham soon left Cornell to join a new wartime laboratory at the Massachusetts Institute of Technology (MIT) and many other colleagues were "drafted" for war work. Bacher persuaded Jerry to join him at the MIT Radiation Laboratory in February

  15. [Vaginitis and vaginosis. Comparison of two periods].

    PubMed

    Ceruti, M; Canestrelli, M; Piantelli, G; Amone, F; Condemi, V; De Paolis, P; Ludovici, G; Somenzi, P

    1993-10-01

    Vaginitis is the most frequent gynecological disease. It is characterized by objective and subjective signs of inflammation and differs from bacterial vaginosis (BV) which is an abnormal condition of the vaginal ecosystem caused by the excessive growth of aerobic and anaerobic flora normally present in the vagina with an increased risk of pelvic inflammatory disease (PID). The authors report the results of a study carried out at the Centre for Gynecological Infections at the Clinic of Obstetrics and Gynecology of the University of Parma. 828 patients were enrolled in the study during the period 1985-86 and 1559 patients during the two-year period 1991-92. The aim of the study was to evaluate variations in epidemiological data for vaginitis and bacterial vaginosis in the two periods examined. No significant changes were observed (p > 0.05) with regard to the prevalence of Ca, Tv and BV forms. On the other hand, there was a significant reduction (p < 0.001) in the forms sustained by other microorganisms (above all, streptococcus and enterobacteria) between the first and second periods with a parallel increase in the number of negative cases. The analysis of the age distribution of vaginitis and BV showed a reduction of other microorganisms and an increase in negative vaginal swabs in adults (> 20 years old).

  16. Diagnostic and therapeutic advancements for aerobic vaginitis.

    PubMed

    Han, Cha; Wu, Wenjuan; Fan, Aiping; Wang, Yingmei; Zhang, Huiying; Chu, Zanjun; Wang, Chen; Xue, Fengxia

    2015-02-01

    Aerobic vaginitis (AV) is a newly defined clinical entity that is distinct from candidiasis, trichomoniasis and bacterial vaginosis (BV). Because of the poor recognition of AV, this condition can lead to treatment failures and is associated with severe complications, such as pelvic inflammatory disease, infertility, preterm birth and foetal infections. This review describes the diagnosis and treatment of AV and the relationship between AV and pregnancy. The characteristics of AV include severely depressed levels of lactobacilli, increased levels of aerobic bacteria and an inflamed vagina. The diagnosis is made by microscopy on wet mounts of fresh vaginal fluid, and some distinct clinical features are recognized. Vaginal suppositories that contain kanamycin or clindamycin have shown curative effects in nonpregnant women. Additionally, the application of topical probiotics can restore the vaginal flora and reduce the recurrence of AV. Clindamycin vaginal suppositories and probiotics may be a better choice for gravida with AV than metronidazole. AV requires prompt attention, and the early diagnosis and treatment of AV during pregnancy significantly improves perinatal outcomes. Further research is needed to define the pathogenesis, diagnostic criteria and standard treatment guidelines for AV.

  17. The vaginal microbiota and susceptibility to HIV.

    PubMed

    Buve, Anne; Jespers, Vicky; Crucitti, Tania; Fichorova, Raina N

    2014-10-23

    There is some evidence that the risk of HIV infection per heterosexual act is higher in low-income countries than in high-income countries. We hypothesize that variations in per sex-act transmission probability of HIV may in part be attributed to differences in the composition and function of the vaginal microbiota between different populations. This paper presents data that are in support of this hypothesis. Experimental and clinical studies have provided evidence that the normal vaginal microbiota plays a protective role against acquisition of HIV and other sexually transmitted infections. Epidemiological studies have convincingly shown that disturbances of the vaginal microbiome, namely intermediate flora and bacterial vaginosis, increase the risk of acquisition of HIV infection. A review of the literature found large differences in prevalence of bacterial vaginosis between different populations, with the highest prevalence rates found in black populations. Possible explanations for these differences are presented including data suggesting that there are ethnic differences in the composition of the normal vaginal microbiota. Lastly, interventions are discussed to restore and maintain a healthy vaginal environment. 2014 Wolters Kluwer Health | Lippincott Williams & Wilkins

  18. Group B Streptococcus and the Vaginal Microbiota.

    PubMed

    Rosen, Geoffrey H; Randis, Tara M; Desai, Purnahamsi V; Sapra, Katherine J; Ma, Bing; Gajer, Pawel; Humphrys, Michael S; Ravel, Jacques; Gelber, Shari E; Ratner, Adam J

    2017-09-15

    Streptococcus agalactiae (group B Streptococcus [GBS]) is an important neonatal pathogen and emerging cause of disease in adults. The major risk factor for neonatal disease is maternal vaginal colonization. However, little is known about the relationship between GBS and vaginal microbiota. Vaginal lavage samples from nonpregnant women were tested for GBS, and amplicon-based sequencing targeting the 16S ribosomal RNA V3-V4 region was performed. Four hundred twenty-eight of 432 samples met the high-quality read threshold. There was no relationship between GBS carriage and demographic characteristics, α-diversity, or overall vaginal microbiota community state type (CST). Within the non-Lactobacillus-dominant CST IV, GBS positive status was significantly more prevalent in CST IV-A than CST IV-B. Significant clustering by GBS status was noted on principal coordinates analysis, and 18 individual taxa were found to be significantly associated with GBS carriage by linear discriminant analysis. After adjusting for race/ethnicity, 4 taxa were positively associated with GBS, and 6 were negatively associated. Vaginal microbiota CST and α-diversity are not related to GBS status. However, specific microbial taxa are associated with colonization of this important human pathogen, highlighting a potential role for the microbiota in promotion or inhibition of GBS colonization. © The Author 2017. Published by Oxford University Press for the Infectious Diseases Society of America. All rights reserved. For permissions, e-mail: journals.permissions@oup.com.

  19. [Clinical characteristics of aerobic vaginitis and its mixed infections].

    PubMed

    Fan, Ai-Ping; Xue, Feng-Xia

    2010-12-01

    To investigate clinical characteristics of aerobic vaginitis (AV) and its mixed infections for diagnosis efficiently. From April 2008 to December 2008, 516 patients with vaginitis treated in Tianjin Medical University General Hospital were enrolled in this study. AV, bacterial vaginosis (BV), vulvovaginal candidiasis (VVC), trichomonal vaginitis (TV), and cytolytic vaginosis (CV) were diagnosed based on symptoms, sign and vaginal discharge examination. Among 516 cases, AV cases were found in 14.7% (76/516), and AV was common vaginal infection. AV mixed infections was diagnosed in 58% (44/76), including mixed with BV (45%, 20/44), mixed with VVC (30%, 13/44), and mixed with TV (25%, 11/44). Those common symptom of AV were yellow vaginal discharge (63%, 20/32), more vaginal discharge (44%, 14/32). Vaginal pH value was usually more than 4.5 (84%, 27/32). Vaginal cleanliness mainly was grade III - IV (88%, 28/32). Six cases with enterococcus faecium and 4 cases with streptococci were frequently isolated. The symptom and sign of mixed AV infection was atypical. Aerobic vaginitis is a common lower vaginal infection and easily mixed with other pathogens, especially with BV, VVC or TV. When patients were diagnosed with AV or other vaginal infection, it should be mentioned whether those patients have mixed vaginal infection or AV.

  20. Administration of oral and vaginal prebiotic lactoferrin for a woman with a refractory vaginitis recurring preterm delivery: appearance of lactobacillus in vaginal flora followed by term delivery.

    PubMed

    Otsuki, Katsufumi; Tokunaka, Mayumi; Oba, Tomohiro; Nakamura, Masamitsu; Shirato, Nahoko; Okai, Takashi

    2014-02-01

    Lactoferrin (LF) is one of the prebiotics present in the human body. A 38-year-old multiparous woman with poor obstetrical histories, three consecutive preterm premature rupture of membrane at the 19th, 23rd and 25th week of pregnancy, was referred to our hospital. She was diagnosed as having refractory vaginitis. Although estriol vaginal tablets were used for 4 months, the vaginitis was not cured. We administrated vaginal tablets and oral agents of prebiotic LF, resulting in a Lactobacillus predominant vaginal flora. When she was pregnant, she continued to use the LF, and the Lactobacillus in the vaginal flora was continuously observed during pregnancy. An elective cesarean section was performed at the 38th week of pregnancy. When the administration of LF was discontinued after the delivery, Lactobacillus in the vaginal flora was disappeared. © 2013 The Authors. Journal of Obstetrics and Gynaecology Research © 2013 Japan Society of Obstetrics and Gynecology.