New suturing technique for robotic-assisted vaginal cuff closure during single-site hysterectomy.
Shin, So-Jin; Chung, Hyewon; Kwon, Sang-Hoon; Cha, Soon-Do; Cho, Chi-Heum
2017-06-01
To describe a simple and efficient technique for suturing the vaginal cuff in robotic-assisted single-site hysterectomy using barbed suture and a straight needle. Consecutive patients undergoing robotic-assisted single-site hysterectomy from February 2014 to August 2015 at Dong San Hospital, Keimyung University were included. Surgeons used two barbed sutures in a running fashion to close the vaginal cuff. A barbed suture was exclusively used with a straightened needle in upward direction from posterior vaginal cuff to anterior vaginal cuff which played a pivotal role for closure. A total of 100 patients underwent robotic-assisted single-site hysterectomy. The total operation time was 132.5 min and vaginal cuff closure time was 12.0 min. There were no postoperative complications; vaginal cuff dehiscence, vaginal cuff infection, and vaginal bleeding that require surgical intervention or admission. The use of barbed suture with straightened needle to close the vaginal cuff in robotic-assisted single-site hysterectomy is easy to perform and demonstrates safety and efficacy. This technique offers secure, fast, and effective incision closure.
Drudi, Laura; Press, Joshua Z; Lau, Susie; Gotlieb, Raphael; How, Jeffrey; Eniu, Ioana; Drummond, Nancy; Brin, Sonya; Deland, Claire; Gotlieb, Walter H
2013-06-01
Vaginal vault dehiscence following robotic-assisted hysterectomy for gynecologic cancer may be attributed to surgical techniques and postoperative therapeutic interventions. We searched for risk factors in patients with gynecologic cancers and complemented this with a literature review. Evaluation of prospectively gathered information on all consecutive robotic surgeries for gynecologic cancers was performed in a tertiary academic cancer center between December 2007 and March 2012. The literature was reviewed for articles relevant to "gynecologic oncology" and "robotics" with "vaginal cuff dehiscence" in the English and French languages. Respective authors were contacted to complete relevant information. Seven dehiscences were identified of 441 cases with established gynecologic cancers. The closures in these 7 were performed using interrupted 1-Vicryl (Ethicon Inc) (3/167; 1.8%), combination of interrupted 1-Vicryl and 1-Biosyn (Covidien Inc) (3/156, 1.9%), and V-Loc (Covidien Inc) (1/118, 0.8%) sutures. Associated risk factors included adjuvant chemotherapy and/or brachytherapy, early resumption of sexual activity, and low body mass index (mean, 23 ± 3.23 kg/m²). Dehiscences occurred regardless of suturing by staff or trainees. Review of operative videos did not reveal a detectable etiologic factor, such as excessive cautery damage to the vaginal cuff or shallow tissue sutured. All 7 colporrhexis repairs were performed through a vaginal approach without the need of laparoscopy or laparotomy. Postoperative chemotherapy, brachytherapy, and early resumption of sexual activities are risk factors for vaginal vault dehiscence. Surgical technique, particularly the use of delayed absorbable sutures, deserves further evaluation.
Vaginal cuff dehiscence after intracavitary brachytherapy for endometrial cancer
Shah, Karan; Potkul, Ronald
2012-01-01
We describe 2 unusual cases of vaginal dehiscence after intracavitary brachytherapy performed following robotic laparoscopic hysterectomy (RLH) along with their management. This unusual complication, which may be more common because of the robotic procedures, can be prevented by careful examination and possible delay of the onset of brachytherapy, if indicated. Our report reviews techniques of avoiding this complication and suggests that these complications should be discussed with the patients. PMID:23349653
Magnitude of Interfractional Vaginal Cuff Movement: Implications for External Irradiation
DOE Office of Scientific and Technical Information (OSTI.GOV)
Ma, Daniel J.; Michaletz-Lorenz, Martha; Goddu, S. Murty
2012-03-15
Purpose: To quantify the extent of interfractional vaginal cuff movement in patients receiving postoperative irradiation for cervical or endometrial cancer in the absence of bowel/bladder instruction. Methods and Materials: Eleven consecutive patients with cervical or endometrial cancer underwent placement of three gold seed fiducial markers in the vaginal cuff apex as part of standard of care before simulation. Patients subsequently underwent external irradiation and brachytherapy treatment based on institutional guidelines. Daily megavoltage CT imaging was performed during each external radiation treatment fraction. The daily positions of the vaginal apex fiducial markers were subsequently compared with the original position of themore » fiducial markers on the simulation CT. Composite dose-volume histograms were also created by summing daily target positions. Results: The average ({+-} standard deviation) vaginal cuff movement throughout daily pelvic external radiotherapy when referenced to the simulation position was 16.2 {+-} 8.3 mm. The maximum vaginal cuff movement for any patient during treatment was 34.5 mm. In the axial plane the mean vaginal cuff movement was 12.9 {+-} 6.7 mm. The maximum vaginal cuff axial movement was 30.7 mm. In the craniocaudal axis the mean movement was 10.3 {+-} 7.6 mm, with a maximum movement of 27.0 mm. Probability of cuff excursion outside of the clinical target volume steadily dropped as margin size increased (53%, 26%, 4.2%, and 1.4% for 1.0, 1.5, 2.0, and 2.5 cm, respectively.) However, rectal and bladder doses steadily increased with larger margin sizes. Conclusions: The magnitude of vaginal cuff movement is highly patient specific and can impact target coverage in patients without bowel/bladder instructions at simulation. The use of vaginal cuff fiducials can help identify patients at risk for target volume excursion.« less
Cavkaytar, Sabri; Kokanali, Mahmut Kuntay; Topcu, Hasan Onur; Aksakal, Orhan Seyfi; Doganay, Melike
2014-01-01
To compare the effects of horizontal and vertical vaginal cuff closure techniques on vagina length after vaginal hysterectomy. Prospective randomized study (Canadian Task Force classification I). Teaching and research hospital, a tertiary center. Fifty-two women with POP-Q stage 0 or 1 uterine prolapse were randomized into 2 groups using vertical (n = 26) or horizontal (n = 26) vaginal cuff closure. All patients underwent vaginal hysterectomy. Vagina length in the 2 groups was compared preoperatively, immediately after surgery, and at 6 weeks postoperatively. Mean (SD) preoperative vagina length in the horizontal and vertical groups was similar (7.87 [0.92] cm vs 7.99 [0.78] cm; p = .41). Immediately postoperatively, the vagina was significantly shorter in the horizontal group than in the vertical group (6.61 [0.89] cm vs 7.51 [0.74] cm; p < .001). At 6 weeks postoperatively, the vagina was still significantly shorter in the horizontal group (6.55 [0.89] cm vs 7.42 (0.73) cm; p < .001). The mean difference in vagina length before and after surgery was also significantly higher in the horizontal group than in the vertical group (-1.26 [0.12] cm vs 0.49 [0.11] cm; p < .001). Vertical cuff closure during vaginal hysterectomy seems to preserve vagina length better than does horizontal cuff closure. Copyright © 2014 AAGL. Published by Elsevier Inc. All rights reserved.
Murakami, Naoya; Norihisa, Yoshiki; Isohashi, Fumiaki; Murofushi, Keiko; Ariga, Takuro; Kato, Tomoyasu; Inaba, Koji; Okamoto, Hiroyuki; Ito, Yoshinori; Toita, Takafumi; Itami, Jun
2016-01-01
The aim of this study was to develop an appropriate definition for vaginal cuff and paracolpium clinical target volume (CTV) for postoperative intensity modulated radiation therapy in patients with uterine cervical cancer. A working subgroup was organized within the Radiation Therapy Study Group of the Japan Clinical Oncology Group to develop a definition for the postoperative vaginal cuff and paracolpium CTV in December 2013. The group consisted of 5 radiation oncologists who specialized in gynecologic oncology and a gynecologic oncologist. A comprehensive literature review that included anatomy, surgery, and imaging fields was performed and was followed by multiple discreet face-to-face discussions and e-mail messages before a final consensus was reached. Definitions for the landmark structures in all directions that demarcate the vaginal cuff and paracolpium CTV were decided by consensus agreement of the working group. A table was created that showed boundary structures of the vaginal cuff and paracolpium CTV in each direction. A definition of the postoperative cervical cancer vaginal cuff and paracolpium CTV was developed. It is expected that this definition guideline will serve as a template for future radiation therapy clinical trial protocols, especially protocols involving intensity modulated radiation therapy. Copyright © 2016 American Society for Radiation Oncology. Published by Elsevier Inc. All rights reserved.
Monroe, Alan T; Pikaart, Dirk; Peddada, Anuj V
2013-06-01
To report two year clinical outcomes of image guided radiation therapy (IGRT) to the vaginal cuff and pelvic lymph nodes in a series of high-risk endometrial cancer patients. Twenty-six consecutive high-risk endometrial cancer patients requiring adjuvant radiation to the vaginal cuff and regional lymph nodes were treated with vaginal cuff fiducial-based IGRT. Seventeen (65%) received sequential chemotherapy, most commonly with a sandwich technique. Brachytherapy followed external radiation in 11 patients to a median dose of 18 Gy in 3 fractions. The median external beam dose delivered was 47.5 Gy in 25 fractions. All 656 fractions were successfully imaged and treated. The median overall translational shift required for correction was 9.1 mm (standard deviation, 5.2 mm) relative to clinical set-up with skin tattoos. Shifts of 1 cm, 1.5 cm, and 2 cm or greater were performed in 43%, 14%, and 4% of patients, respectively. Acute grade 2 gastrointestinal (GI) toxicity occurred in eight patients (30%) and grade 3 toxicity occurred in one. At two years, there have been no local or regional failures and actuarial overall survival is 95%. Daily image guidance for high-risk endometrial cancer results in a low incidence of acute GI/genitourinary (GU) toxicity with uncompromised tumor control at two years. Vaginal cuff translations can be substantial and may possibly result in underdosing if not properly considered.
Teoh, Deanna; Lowery, William J; Jiang, Xiaoyin; Ehrisman, Jessie; Halvorson, Paige; Broadwater, Gloria; Bentley, Rex; Secord, Angeles Alvarez; Sobolewski, Craig; Berchuck, Andrew; Havrilesky, Laura J; Valea, Fidel A; Lee, Paula S
2015-02-01
To evaluate if the use of Valleylab mode ("V mode") (Covidien, Mansfield, MA) electrothermal energy for colpotomy during total laparoscopic hysterectomy (LH) results in a smaller margin of thermal injury to the upper vagina compared with traditional cut/coagulate (cut/coag) electrothermal energy. Prospective randomized clinical trial (Canadian Task Force classification I). University medical center. A total of 101 subjects who underwent LH between June 2010 and August 2012. Subjects were randomized to colpotomy by V mode electrothermal energy or cut/coag electrothermal energy. The primary end point was the median depth of thermal injury measured in millimeters. The secondary end points included the proportion of subjects who developed granulation tissue, induration, infection, or dehiscence at the vaginal cuff at 4 weeks, 3 months, or 6 months postoperatively. There was no significant difference in the median depth of thermal injury in the cut/coag and V mode arms (anterior margin: 0.68 mm vs 0.63 mm [p = .94], posterior margin: 0.66 mm vs 0.70 mm [p = .87], respectively). Twenty-seven percent of subjects in each arm developed at least 1 of the clinical end points at 4 weeks, 3 months, or 6 months postoperatively (granulation tissue: 6%-18% vs 8%-21%, induration: 0%-2% vs 4%-5%, infection: 0%-4% vs 0%-10%, dehiscence: 2% vs 0% in the cut/coag and V mode arms, respectively), with no difference between arms (p = 1.0). The V mode does not reduce the depth of thermal injury compared with cut/coag electrothermal energy when used for colpotomy incision during total laparoscopic hysterectomy (Clinical Trials.gov ID: NCT02080546). Copyright © 2015 AAGL. Published by Elsevier Inc. All rights reserved.
Optimisation techniques in vaginal cuff brachytherapy.
Tuncel, N; Garipagaoglu, M; Kizildag, A U; Andic, F; Toy, A
2009-11-01
The aim of this study was to explore whether an in-house dosimetry protocol and optimisation method are able to produce a homogeneous dose distribution in the target volume, and how often optimisation is required in vaginal cuff brachytherapy. Treatment planning was carried out for 109 fractions in 33 patients who underwent high dose rate iridium-192 (Ir(192)) brachytherapy using Fletcher ovoids. Dose prescription and normalisation were performed to catheter-oriented lateral dose points (dps) within a range of 90-110% of the prescribed dose. The in-house vaginal apex point (Vk), alternative vaginal apex point (Vk'), International Commission on Radiation Units and Measurements (ICRU) rectal point (Rg) and bladder point (Bl) doses were calculated. Time-position optimisations were made considering dps, Vk and Rg doses. Keeping the Vk dose higher than 95% and the Rg dose less than 85% of the prescribed dose was intended. Target dose homogeneity, optimisation frequency and the relationship between prescribed dose, Vk, Vk', Rg and ovoid diameter were investigated. The mean target dose was 99+/-7.4% of the prescription dose. Optimisation was required in 92 out of 109 (83%) fractions. Ovoid diameter had a significant effect on Rg (p = 0.002), Vk (p = 0.018), Vk' (p = 0.034), minimum dps (p = 0.021) and maximum dps (p<0.001). Rg, Vk and Vk' doses with 2.5 cm diameter ovoids were significantly higher than with 2 cm and 1.5 cm ovoids. Catheter-oriented dose point normalisation provided a homogeneous dose distribution with a 99+/-7.4% mean dose within the target volume, requiring time-position optimisation.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Stewart, Alexandra J.; Cormack, Robert A.; Lee, Hang
2008-11-01
Purpose: To investigate the effect of bladder filling on dosimetry and to determine the best bladder dosimetric parameter for vaginal cuff brachytherapy. Methods and Materials: In this prospective clinical trial, a total of 20 women underwent vaginal cylinder high-dose-rate brachytherapy. The bladder was full for Fraction 2 and empty for Fraction 3. Dose-volume histogram and dose-surface histogram values were generated for the bladder, rectum, and urethra. The midline maximal bladder point (MBP) and the midline maximal rectal point were recorded. Paired t tests, Pearson correlations, and regression analyses were performed. Results: The volume and surface area of the irradiated bladdermore » were significantly smaller when the bladder was empty than when full. Of the several dose-volume histogram and dose-surface histogram parameters evaluated, the bladder maximal dose received by 2 cm{sup 3} of tissue, volume of bladder receiving {>=}50% of the dose, volume of bladder receiving {>=}70% of the dose, and surface area of bladder receiving {>=}50% of the dose significantly predicted for the difference between the empty vs. full filling state. The volume of bladder receiving {>=}70% of the dose and the maximal dose received by 2 cm{sup 3} of tissue correlated significantly with the MBP. Bladder filling did not alter the volume or surface area of the rectum irradiated. However, an empty bladder did result in the nearest point of bowel being significantly closer to the vaginal cylinder than when the bladder was full. Conclusions: Patients undergoing vaginal cuff brachytherapy treated with an empty bladder have a lower bladder dose than those treated with a full bladder. The MBP correlated well with the volumetric assessments of bladder dose and provided a noninvasive method for reporting the MBP dose using three-dimensional imaging. The MBP can therefore be used as a surrogate for complex dosimetry in the clinic.« less
Hovgaard, Lisette Hvid; Andersen, Steven Arild Wuyts; Konge, Lars; Dalsgaard, Torur; Larsen, Christian Rifbjerg
2018-03-30
The use of robotic surgery for minimally invasive procedures has increased considerably over the last decade. Robotic surgery has potential advantages compared to laparoscopic surgery but also requires new skills. Using virtual reality (VR) simulation to facilitate the acquisition of these new skills could potentially benefit training of robotic surgical skills and also be a crucial step in developing a robotic surgical training curriculum. The study's objective was to establish validity evidence for a simulation-based test for procedural competency for the vaginal cuff closure procedure that can be used in a future simulation-based, mastery learning training curriculum. Eleven novice gynaecological surgeons without prior robotic experience and 11 experienced gynaecological robotic surgeons (> 30 robotic procedures) were recruited. After familiarization with the VR simulator, participants completed the module 'Guided Vaginal Cuff Closure' six times. Validity evidence was investigated for 18 preselected simulator metrics. The internal consistency was assessed using Cronbach's alpha and a composite score was calculated based on metrics with significant discriminative ability between the two groups. Finally, a pass/fail standard was established using the contrasting groups' method. The experienced surgeons significantly outperformed the novice surgeons on 6 of the 18 metrics. The internal consistency was 0.58 (Cronbach's alpha). The experienced surgeons' mean composite score for all six repetitions were significantly better than the novice surgeons' (76.1 vs. 63.0, respectively, p < 0.001). A pass/fail standard of 75/100 was established. Four novice surgeons passed this standard (false positives) and three experienced surgeons failed (false negatives). Our study has gathered validity evidence for a simulation-based test for procedural robotic surgical competency in the vaginal cuff closure procedure and established a credible pass/fail standard for future
Houten, John K; Smith, Shiela; Schwartz, Amit Y
2017-08-01
Ventriculoperitoneal (VP) shunting is a common neurosurgical procedure to treat hydrocephalus that diverts cerebrospinal fluid from the cerebral ventricles to the peritoneal cavity for reabsorption. The distal catheter may potentially migrate through any potential or iatrogenic opening in the peritoneal cavity. Increasingly successfully management of childhood hydrocephalus and adult-onset conditions leading to hydrocephalus, such as subarachnoid hemorrhage, is leading many adult female patients harboring VP shunts needing to undergo hysterectomy. Hysterectomy creates a potential defect though which a VP shunt catheter may migrate. It is not known whether the hysterectomy cuff closure technique may affect the likelihood of distal catheter migration though the repair site. We report the case of a 38-year-old woman with a VP shunt who underwent laparoscopic hysterectomy via an open vaginal cuff technique who subsequently presented with vaginal cerebrospinal fluid leakage secondary to migration of the distal shunt catheter through the hysterectomy cuff. Vaginal migration of the distal VP shunt catheter is a possible complication of hysterectomy. The authors postulate that an open cuff hysterectomy closure technique may increase the risk of catheter migration, an issue that may be better understood with further investigation. Copyright © 2017 Elsevier Inc. All rights reserved.
Factors influencing wound dehiscence.
Riou, J P; Cohen, J R; Johnson, H
1992-03-01
Thirty-one abdominal fascial wound dehiscences occurred in 2,761 patients undergoing major abdominal surgery during a 5-year period (1%). Twenty-two specific local and systemic risk factors were analyzed and compared with the risk factors of a control group of 38 patients undergoing similar procedures without dehiscence. Through multivariate analysis, each factor was assessed as an independent statistical variable. Significant factors (p less than 0.05) were found to include age over 65, wound infection, pulmonary disease, hemodynamic instability, and ostomies in the incision. Additional systemic risk factors that were found to be significant included hypoproteinemia, systemic infection, obesity, uremia, hyperalimentation, malignancy, ascites, steroid use, and hypertension. Risk factors not found to be important independent variables included sex, type of incision, type of closure, foreign body in the wound, anemia, jaundice, and diabetes. When dehiscence and control groups were combined, 30% of patients with at least five significant risk factors developed dehiscence, and all the patients with more than eight risk factors developed a wound dehiscence. There was an overall mortality of 29%, which was directly related to the number of significant risk factors. The co-existence of 9 risk factors portended death in one third of the patients, and all the patients with more than 10 risk factors died.
Ethylene: role in fruit abscission and dehiscence processes.
Lipe, J A; Morgan, P W
1972-12-01
Two peaks of ethylene production occur during the development of cotton fruitz (Gossypium hirsutum L.). These periods precede the occurrence of young fruit shedding and mature fruit dehiscence, both of which are abscission phenomena and the latter is generally assumed to be part of the total ripening process. Detailed study of the dehiscence process revealed that ethylene production of individual, attached cotton fruits goes through a rising, cyclic pattern which reaches a maximum prior to dehiscence. With detached pecan fruits (Carya illinoensis [Wang.] K. Koch), ethylene production measured on alternate days rose above 1 microliter per kilogram fresh weight per hour before dehiscence began and reached a peak several days prior to complete dehiscence. Ethylene production by cotton and pecan fruits was measured just prior to dehiscence and then the internal concentration of the gas near the center of the fruit was determined. From these data a ratio of production rate to internal concentration was determined which allowed calculation of the approximate ethylene concentration in the intact fruit prior to dehiscence and selection of appropriate levels to apply to fruits. Ethylene at 10 microliters per liter of air appears to saturate dehiscence of cotton, pecan, and okra (Hibiscus esculentus L.) fruits and the process is completed in 3 to 4 days. In all cases some hastening of dehiscence was observed with as little as 0.1 microliter of exogenous ethylene per liter of air. The time required for response to different levels of ethylene was determined and compared to the time course of ethylene production and dehiscence. We concluded that internal levels of ethylene rose to dehiscence-stimulating levels a sufficience time before dehiscence for the gas to have initiated the process. Since our data and calculations indicate that enough ethylene is made a sufficient time before dehiscence, to account for the process, we propose that ethylene is one of the regulators of
Ethylene: Role in Fruit Abscission and Dehiscence Processes 12
Lipe, John A.; Morgan, Page W.
1972-01-01
Two peaks of ethylene production occur during the development of cotton fruitz (Gossypium hirsutum L.). These periods precede the occurrence of young fruit shedding and mature fruit dehiscence, both of which are abscission phenomena and the latter is generally assumed to be part of the total ripening process. Detailed study of the dehiscence process revealed that ethylene production of individual, attached cotton fruits goes through a rising, cyclic pattern which reaches a maximum prior to dehiscence. With detached pecan fruits (Carya illinoensis [Wang.] K. Koch), ethylene production measured on alternate days rose above 1 microliter per kilogram fresh weight per hour before dehiscence began and reached a peak several days prior to complete dehiscence. Ethylene production by cotton and pecan fruits was measured just prior to dehiscence and then the internal concentration of the gas near the center of the fruit was determined. From these data a ratio of production rate to internal concentration was determined which allowed calculation of the approximate ethylene concentration in the intact fruit prior to dehiscence and selection of appropriate levels to apply to fruits. Ethylene at 10 microliters per liter of air appears to saturate dehiscence of cotton, pecan, and okra (Hibiscus esculentus L.) fruits and the process is completed in 3 to 4 days. In all cases some hastening of dehiscence was observed with as little as 0.1 microliter of exogenous ethylene per liter of air. The time required for response to different levels of ethylene was determined and compared to the time course of ethylene production and dehiscence. We concluded that internal levels of ethylene rose to dehiscence-stimulating levels a sufficience time before dehiscence for the gas to have initiated the process. Since our data and calculations indicate that enough ethylene is made a sufficient time before dehiscence, to account for the process, we propose that ethylene is one of the regulators of
Gender and laterality in semicircular canal dehiscence syndrome.
Karimnejad, K; Czerny, M S; Lookabaugh, S; Lee, D J; Mikulec, A A
2016-08-01
To determine if there is gender or laterality predilection in patients with semicircular canal dehiscence syndrome. A multi-institutional chart review was performed to identify patients diagnosed with semicircular canal dehiscence between 2000 and 2015. A systematic literature search was conducted using PubMed to further identify patients with semicircular canal dehiscence. Age, gender and laterality data were collected. Statistical analysis was performed to evaluate for gender or laterality preponderance. A total of 682 patients with semicircular canal dehiscence were identified by literature and chart review. Mean age of diagnosis was 49.75 years (standard deviation = 15.33). Semicircular canal dehiscence was associated with a statistically significant female predominance (chi-square = 7.185, p = 0.007); the female-to-male ratio was 1.2 to 1. Left-sided semicircular canal dehiscence was most common, followed by right-sided then bilateral (chi-square = 23.457, p < 0.001). Semicircular canal dehiscence syndrome is most commonly left-sided and exhibits a female predominance. This may be secondary to morphological cerebral hemisphere asymmetries in both sexes and a predilection of women to seek more medical care than men.
Dudley, L; Kettle, C; Waterfield, J; Ismail, Khaled M K
2017-02-10
To explore women's lived experiences of a dehisced perineal wound following childbirth and how they felt participating in a pilot and feasibility randomised controlled trial (RCT). A nested qualitative study using semistructured interviews, underpinned by descriptive phenomenology. A purposive sample of six women at 6-9 months postnatal who participated in the RCT were interviewed in their own homes. Following Giorgi's analytical framework the verbatim transcripts were analysed for key themes. Women's lived experiences revealed 4 emerging themes: (1) Physical impact, with sub-themes focusing upon avoiding infection, perineal pain and the impact of the wound dehiscence upon daily activities; (2) Psychosocial impact, with sub-themes of denial, sense of failure or self-blame, fear, isolation and altered body image; (3) Sexual impact; and (4) Satisfaction with wound healing. A fifth theme 'participating in the RCT' was 'a priori' with sub-themes centred upon understanding the randomisation process, completing the trial questionnaires, attending for hospital appointments and acceptability of the treatment options. To the best of our knowledge, this is the first qualitative study to grant women the opportunity to voice their personal experiences of a dehisced perineal wound and their views on the management offered. The powerful testimonies presented disclose the extent of morbidity experienced while also revealing a strong preference for a treatment option. ISRCTN05754020; results. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://www.bmj.com/company/products-services/rights-and-licensing/.
Superior Canal Dehiscence Syndrome Affecting 3 Families.
Heidenreich, Katherine D; Kileny, Paul R; Ahmed, Sameer; El-Kashlan, Hussam K; Melendez, Tori L; Basura, Gregory J; Lesperance, Marci M
2017-07-01
Superior canal dehiscence syndrome (SCDS) is an increasingly recognized cause of hearing loss and vestibular symptoms, but the etiology of this condition remains unknown. To describe 7 cases of SCDS across 3 families. This retrospective case series included 7 patients from 3 different families treated at a neurotology clinic at a tertiary academic medical center from 2010 to 2014. Patients were referred by other otolaryngologists or were self-referred. Each patient demonstrated unilateral or bilateral SCDS or near dehiscence. Clinical evaluation involved body mass index calculation, audiometry, cervical vestibular evoked myogenic potential testing, electrocochleography, and multiplanar computed tomographic (CT) scan of the temporal bones. Zygosity testing was performed on twin siblings. The diagnosis of SCDS was made if bone was absent over the superior semicircular canal on 2 consecutive CT images, in addition to 1 physiologic sign consistent with labyrinthine dehiscence. Near dehiscence was defined as absent bone on only 1 CT image but with symptoms and at least 1 physiologic sign of labyrinthine dehiscence. A total of 7 patients (5 female and 2 male; age range, 8-49 years) from 3 families underwent evaluation. Family A consisted of 3 adult first-degree relatives, of whom 2 were diagnosed with SCDS and 1 with near dehiscence. Family B included a mother and her child, both of whom were diagnosed with unilateral SCDS. Family C consisted of adult monozygotic twins, each of whom was diagnosed with unilateral SCDS. For all cases, dehiscence was located at the arcuate eminence. Obesity alone did not explain the occurrence of SCDS because 5 of the 7 cases had a body mass index (calculated as weight in kilograms divided by height in meters squared) less than 30.0. Superior canal dehiscence syndrome is a rare, often unrecognized condition. This report of 3 multiplex families with SCDS provides evidence in support of a potential genetic contribution to the etiology
Ethylene: Response of Fruit Dehiscence to CO(2) and Reduced Pressure.
Lipe, J A; Morgan, P W
1972-12-01
These studies were conducted to determine whether ethylene serves as a natural regulator of fruit wall dehiscence, a major visible feature of ripening in some fruits. We employed treatments to inhibit ethylene action or remove ethylene and observed their effect on fruit dehiscence. CO(2) (13%), a competitive inhibitor of ethylene action in many systems, readily delayed dehiscence of detached fruits of cotton (Gossypium hirsutum L.), pecan (Carya illinoensis [Wang.] K. Koch), and okra (Hibiscus esculentus L.). The CO(2) effect was duplicated by placing fruits under reduced pressure (200 millimeters mercury), to promote the escape of ethylene from the tissue. Dehiscence of detached fruits of these species as well as attached cotton fruits was delayed. The delay of dehiscence of cotton and okra by both treatments was achieved with fruit harvested at intervals from shortly after anthesis until shortly before natural dehiscence. Pecan fruits would not dehisce until approximately 1 month before natural dehiscence, and during that time, CO(2) and reduced pressure delayed dehiscence. CO(2) and ethylene were competitive in their effects on cotton fruit dehiscence. All of the results are compatible with a hypothetical role of ethylene as a natural regulator of dehiscence, a dominant aspect of ripening of cotton, pecan, and some other fruits.
Salvaging the dehisced glans penis.
White, C M; Hanna, M K
2018-05-30
The glans penis may show a deep groove (surgically favorable), or may appear flat with an absent sulcus (unfavorable). Glans dehiscence following hypospadias repair, especially after multiple surgeries, frequently results in a scarred, obliterated, or absent urethral plate. The glans penis appears to be flat and grooveless. This study reported on the outcome of a two-stage salvage repair for glans dehiscence in 49 consecutive patients. Retrospective chart review was performed for all patients who underwent repair for glans dehiscence following hypospadias repair. Between January 2009 and April 2015, 49 children aged 16 months to 18 years presented with glans dehiscence following hypospadias repair. The prior number of operations ranged from one to six. Eleven children had urethral fistulas, and seven had chordee. In the first stage, the flat glans was incised deeply to visualize, but spare, the corpora. Thereafter, a free graft of oral mucosa harvested either from the lower lip or cheek, or the residual preputial skin, was sutured to the glans cleft. The grafts were fenestrated, quilted in the midline, and a tie-over dressing was applied. Any fistula or chordee was repaired during the first stage. The neo-plate was tubularized 6-12 months later, and urine drainage with a catheter was maintained for 10-14 days. In 11 patients, skin flaps appeared dusky, and nitroglycerine ointment 2% was applied for 24 h to enhance the blood supply of the tissues. Subsequently, six of these children received nine or ten 90-min hyperbaric oxygen therapy sessions. Following the first stage, two patients developed hypertrophy of the mucosal grafts, and one skin graft contracted. These three patients underwent revision using a second buccal mucosal graft harvested from the cheek. One recurrent fistula was closed during the second stage. Following the second stage two patients developed a urethral fistula, and the distal sutures broke down in one patient, resulting in an over
Ethylene: Response of Fruit Dehiscence to CO2 and Reduced Pressure 1
Lipe, John A.; Morgan, Page W.
1972-01-01
These studies were conducted to determine whether ethylene serves as a natural regulator of fruit wall dehiscence, a major visible feature of ripening in some fruits. We employed treatments to inhibit ethylene action or remove ethylene and observed their effect on fruit dehiscence. CO2 (13%), a competitive inhibitor of ethylene action in many systems, readily delayed dehiscence of detached fruits of cotton (Gossypium hirsutum L.), pecan (Carya illinoensis [Wang.] K. Koch), and okra (Hibiscus esculentus L.). The CO2 effect was duplicated by placing fruits under reduced pressure (200 millimeters mercury), to promote the escape of ethylene from the tissue. Dehiscence of detached fruits of these species as well as attached cotton fruits was delayed. The delay of dehiscence of cotton and okra by both treatments was achieved with fruit harvested at intervals from shortly after anthesis until shortly before natural dehiscence. Pecan fruits would not dehisce until approximately 1 month before natural dehiscence, and during that time, CO2 and reduced pressure delayed dehiscence. CO2 and ethylene were competitive in their effects on cotton fruit dehiscence. All of the results are compatible with a hypothetical role of ethylene as a natural regulator of dehiscence, a dominant aspect of ripening of cotton, pecan, and some other fruits. PMID:16658260
MRI-Based Evaluation of the Vaginal Cuff in Brachytherapy Planning: Are We Missing the Target?
DOE Office of Scientific and Technical Information (OSTI.GOV)
Chapman, Christina Hunter; Prisciandaro, Joann I.; Maturen, Katherine E.
2016-06-01
Purpose: Although recurrences and toxicity occur after vaginal cuff (VC) brachytherapy, little is known about dosimetry due to the inability to clearly visualize the VC on computed tomography (CT). T2-weighted (T2W) magnetic resonance imaging (MRI) is superior to CT in this setting, and we hypothesized that it could provide previously unascertainable dosimetric information. Methods and Materials: In a cohort of 32 patients who underwent cylinder-based brachytherapy for endometrial cancer with available MR simulation images, the VC was retrospectively contoured on T2W images, and cases were replanned to treat the upper VC to a dose of 7 Gy/fraction prescribed to 5 mm. Relevantmore » dose-volume parameters for the VC were calculated. Results: T2W MRI identified significant underdosing not observed on CT or T1-weighted imaging. Over two-thirds (69%) of patients had at least 1 cm{sup 3} of VC that received less than 75% of the prescription dose and half (50%) of patients had a least 1 cm{sup 3} of VC that received less than 50% of the prescription dose. The mean minimum point dose to the VC was 2.4 Gy, or 34% of the intended prescription dose (range: 0.53-6.4 Gy). Conclusions: We identified previously unreported VC underdosing in over two-thirds of our patients, with most of these patients having volumes of undistended VC that received less than half of the prescription dose. The maximum dimension was along the craniocaudal axis in some patients or left-right/anterior-posterior axis in others, suggesting that suture material may be restricting access to the vaginal apex and that alternative applicators may be needed when the diameter of the apex is larger than the introitus. Additional follow-up will be needed to determine whether underdosing is associated with isolated VC failure or whether low failure rates across the cohort suggest that some patients are being exposed to excessive dose and unnecessary risk of toxicity.« less
Postoperative sternal dehiscence in obese patients: incidence and prevention.
Molina, J Ernesto; Lew, Rachel Saik-Leng; Hyland, Kasi J
2004-09-01
Obesity has been identified as the single most important risk factor for postoperative sternal infection in coronary bypass surgery patients. It is also a major risk factor for sternal dehiscence, with or without infection, for any type of cardiac operation. We assessed whether prophylactic measures could prevent this complication. Two studies were conducted. In study A, 3,158 heart surgery patients were analyzed at 3 cardiac units. Obesity was defined as body mass index (BMI) more than 30. Group I (1,253 obese [39.7%]) was compared with group II (1,905 nonobese [60.3%]). Sternal closure was done at the surgeon's preference: (a) plain wires through and through the bone; (b) peristernal figure-of-eight wires; or (c) peristernal method, using stainless-steel cables. In study B, 123 obese patients were prospectively divided into 2 subgroups. Group B-1 (54 patients) underwent lateral prophylactic sternal reinforcement before placement of peristernal wires. Group B-2 (69 patients) had standard sternal closure, as in study A. In study A, group I had 81 dehiscences (6.46%); 78 also suffered deep sternal infection and mediastinitis (96%). Despite treatment, dehiscence recurred in 13, and mortality was 38.4%. In group II nonobese patients, 31 dehisced (1.6%, p = 0.000), with no mortality. In study B, group B-1 (54) had 0% dehiscence versus group B-2 (69) with 6 dehiscences (8.7%). In our study, the rate of obesity is high ( approximately 40%). Sternal dehiscence is real when the BMI is more than 30 (6.46%), and has high morbidity and mortality. Prophylactic sternal reinforcement seems to prevent this complication.
Posterior semicircular canal dehiscence: value of VEMP and multidetector CT.
Vanspauwen, R; Salembier, L; Van den Hauwe, L; Parizel, P; Wuyts, F L; Van de Heyning, P H
2006-01-01
To illustrate that posterior semicircular canal dehiscence can present similarly to superior semicircular canal dehiscence. The symptomatology initially presented as probable Menière's disease evolving into a mixed conductive hearing loss with a Carhart notch-type perceptive component suggestive of otosclerosis-type stapes fixation. A small hole stapedotomy resulted in a dead ear and a horizontal semicircular canal hypofunction. Recurrent incapacitating vertigo attacks developed. Vestibular evoked myogenic potential (VEMP) testing demonstrated intact vestibulocollic reflexes. Additional evaluation with high resolution multidetector computed tomography (MDCT) of the temporal bone showed a dehiscence of the left posterior semicircular canal. Besides superior semicircular canal dehiscence, posterior semicircular canal dehiscence has to be included in the differential diagnosis of atypical Menière's disease and/or low tone conductive hearing loss. The value of performing MDCT before otosclerosis-type surgery is stressed. VEMP might contribute to establishing the differential diagnosis.
[Pterygium surgery and fibrin glue: avoiding dehiscence].
Pérez-Silguero, D; Díaz-Ginory, A; Santana-Rodríguez, C; Pérez-Silguero, M A
2014-01-01
The purpose of the study is to evaluate those cases of pterygium surgery with fibrin sealant that produced dehiscence of the graft, and then apply and evaluate the efficacy of a different surgical technique in an attempt eliminate this complication in previously identified cases of high risk. The first phase is a retrospective study of 42 cases of pterygium surgery. In the second phase, the variation in the surgical technique was prospectively used in 14 cases of pterygium surgery. Cases of recurrent pterygium, broad pterygium, and complicated surgery were identified as the groups with a risk of suffering dehiscence of the graft. With the variant applied surgery no dehiscence occurred when using the variation in surgical technique, with no added complications. Copyright © 2012 Sociedad Española de Oftalmología. Published by Elsevier Espana. All rights reserved.
Tunitsky-Bitton, Elena; Propst, Katie; Muffly, Tyler
2016-03-01
The number of robotically assisted hysterectomies is increasing, and therefore, the opportunities for trainees to become competent in performing traditional laparoscopic hysterectomy are decreasing. Simulation-based training is ideal for filling this gap in training. The objective of the study was to design a surgical model for training in laparoscopic vaginal cuff closure and to present evidence of its validity and reliability as an assessment and training tool. Participants included gynecology staff and trainees at 2 tertiary care centers. Experienced surgeons were also recruited at the combined International Urogynecologic Association and American Urogynecologic Society scientific meeting. Participants included 19 experts and 21 trainees. All participants were recorded using the laparoscopic hysterectomy cuff closure simulation model. The model was constructed using the an advanced uterine manipulation system with a sacrocolopexy tip/vaginal stent, a vaginal cuff constructed from neoprene material and lined with a swimsuit material (nylon and spandex) secured to the vaginal stent with a plastic cable tie. The uterine manipulation system was attached to the fundamentals of laparoscopic surgery laparoscopic training box trainer using a metal bracket. Performance was evaluated using the Global Operative Assessment of Laparoscopic Skills scale. In addition, needle handling, knot tying, and incorporation of epithelial edge were also evaluated. The Student t test was used to compare the scores and the operating times between the groups. Intrarater reliability between the scores by the 2 masked experts was measured using the interclass correlation coefficient. Total and annual experience with laparoscopic suturing and specifically vaginal cuff closure varied greatly among the participants. For the construct validity, the participants in the expert group received significantly higher scores in each of the domains of the Global Operative Assessment of Laparoscopic Skills
The Effect of Superior Semicircular Canal Dehiscence on Intracochlear Sound Pressures
Pisano, Dominic V.; Niesten, Marlien E.F.; Merchant, Saumil N.; Nakajima, Hideko Heidi
2013-01-01
Semicircular canal dehiscence (SCD) is a pathological opening in the bony wall of the inner ear that can result in conductive hearing loss. The hearing loss is variable across patients, and the precise mechanism and source of variability are not fully understood. Simultaneous measurements of basal intracochlear sound pressures in scala vestibuli (SV) and scala tympani (ST) enable quantification of the differential pressure across the cochlear partition, the stimulus that excites the cochlear partition. We used intracochlear sound pressure measurements in cadaveric preparations to study the effects of SCD size. Sound-induced pressures in SV and ST, as well as stapes velocity and ear-canal pressure were measured simultaneously for various sizes of SCD followed by SCD patching. Our results showed that at low frequencies (<600 Hz), SCD decreased the pressure in both SV and ST, as well as differential pressure, and these effects became more pronounced as dehiscence size was increased. Near 100 Hz, SV decreased about 10 dB for a 0.5 mm dehiscence and 20 dB for a 2 mm dehiscence, while ST decreased about 8 dB for a 0.5 mm dehiscence and 18 dB for a 2mm dehiscence. Differential pressure decreased about 10 dB for a 0.5 mm dehiscence and about 20 dB for a 2 mm dehiscense at 100 Hz. In some ears, for frequencies above 1 kHz, the smallest pinpoint dehiscence had bigger effects on the differential pressure (10 dB decrease) than larger dehiscenses (less than 10 dB decrease), suggesting larger hearing losses in this frequency range. These effects due to SCD were reversible by patching the dehiscence. We also showed that under certain circumstances such as SCD, stapes velocity is not related to how the ear can transduce sound across the cochlear partition because it is not directly related to the differential pressure, emphasizing that certain pathologies cannot be fully assessed by measurements such as stapes velocity. PMID:22814034
Bogota bag in the treatment of abdominal wound dehiscence.
Sukumar, N; Shaharin, S; Razman, J; Jasmi, A Y
2004-06-01
A patient who underwent emergency laparotomy for rectal prolapse developed repeated abdominal wound dehiscence and subsequently an enteric fistula. The management of abdominal wound dehiscence is discussed, specifically with regards to the Bogota bag. Use of Bogota bag has been reported worldwide but this may be the first report here.
Variety of audiologic manifestations in patients with superior semicircular canal dehiscence.
Chi, Fang-Lu; Ren, Dong-Dong; Dai, Chun-Fu
2010-01-01
To present diverse symptoms, signs, and findings on diagnostic tests of 11 patients with superior semicircular canal dehiscence (SSCD) syndrome and surgical treatments for dehiscence of 3 patients. Retrospective case review. Tertiary neurotologic and audiologic center. Patients with SSCD documented by history, physical examination, vestibular function testing, and high-resolution computed tomographic scans. Two patients underwent surgical procedures through middle fossa approach, and 1 patient underwent transmastoid repair. The rest underwent conservative treatments. Eleven patients were identified as SSCD. The variety of clinical manifestations, including 1) hearing presentations: mix hearing loss (4 of 11), conductive hearing loss (3 of 11), profound sensorineural hearing loss (2 of 11), and normal hearing (2 of 11); 2) vestibular manifestations: chronic disequilibrium (8 of 11), Tullio phenomenon (7 of 11), Hennebert sign (8 of 11), tinnitus (3 of 11), and autophony (3 of 11); and 3) accompanying disorders: encephalomeningocele (1 of 11). Abnormal nystagmus was identified in 3 patients. Dehiscence of bone overlying superior semicircular canal was confirmed by high-resolution computed tomographic scan in all cases. Three patients underwent operative management. (2 through the middle fossa approach and 1 through a transmastoid repair). Superior semicircular canal dehiscence demonstrates diverse and complex clinical features. Tegmental or petrosal bone rarefaction or mild dehiscences can be a harbinger or an aggressive cause of developing SSCD. No correlation was observed between the size of dehiscence and the severity of vestibular symptoms or the degree of hearing loss. Surgical repair of dehiscence can relieve symptoms with low morbidity.
Conservative Treatment of a Gossypiboma Causing Uterine Wound Dehiscence
Usta, Taner A.; Ozyurek, Sefik E.; Gundogdu, Elif C.
2013-01-01
We present a rare case with gossypiboma following cesarean section which led to uterine wound dehiscence. A 30-year-old woman had been submitted to an emergency cesarean section 4 months previously at another hospital. Clinical and ultrasound findings revealed a large intra-abdominal mass and diffuse peritonitis. At laparotomy, a gossypiboma causing an abscess and uterine wound dehiscence with necrosis of the margins was detected. We performed repetitive wound debridements under broad-spectrum antibiotic cover and eventually resutured the incision. Although hysterectomy has so far been the choice of treatment in the literature once a uterine wound dehiscence had occurred, it was possible in this case to preserve the uterus. PMID:24106624
Gucu, Arif; Toktas, Faruk; Eris, Cuneyt; Ata, Yusuf; Turk, Tamer
2012-01-01
Postoperative sternal dehiscence is a potentially catastrophic sequela to median sternotomy that can cause not only chest-wall discomfort and pulmonary dysfunction but infection, both superficial and mediastinal. Nitinol thermoreactive clips use a novel material in the treatment of sternal dehiscence. We sought to determine whether the use of these clips is an effective remedy for noninfective sternal dehiscence. From January 2008 through December 2011, we retrospectively studied the data on 10 patients whose sternums had been closed with nitinol thermoreactive clips after the development of noninfective sternal dehiscence. Diagnosis was made on the bases of clinical criteria, chest radiography, and microbiological investigation. There was no control group. No procedure-related sequelae occurred. There was no recurrent sternal instability and dehiscence, sternal-related hemorrhage, superficial wound infection, or mediastinal infection. We believe that the use of nitinol thermoreactive clips is a safe, easy, and efficient method of secondary sternal closure for noninfective sternal dehiscence. PMID:22949767
... smooth layer) lining these tendons. A rotator cuff tear occurs when one of the tendons is torn ... Poor posture over many years Aging Rotator cuff tears TEARS Rotator cuff tears may occur in two ...
Handcrafted cuff manometers do not accurately measure endotracheal tube cuff pressure
Annoni, Raquel; de Almeida, Antonio Evanir
2015-01-01
Objective To test the agreement between two handcrafted devices and a cuff-specific manometer. Methods The agreement between two handcrafted devices adapted to measure tracheal tube cuff pressure and a cuff-specific manometer was tested on 79 subjects. The cuff pressure was measured with a commercial manometer and with two handcrafted devices (HD) assembled with aneroid sphygmomanometers (HD1 and HD2). The data were compared using Wilcoxon and Spearman tests, the intraclass correlation coefficient (ICC) and limit-of-agreement analysis. Results Cuff pressures assessed with handcrafted devices were significantly different from commercial device measurements (pressures were higher when measured with HD1 and lower with HD2). The ICCs between the commercial device and HD1 and HD2 were excellent (ICC = 0.8 p < 0.001) and good (ICC = 0.66, p < 0.001), respectively. However, the Bland- Altman plots showed wide limits of agreement between HD1 and HD2 and the commercial device. Conclusion The handcrafted manometers do not provide accurate cuff pressure measurements when compared to a cuff-specific device and should not be used to replace the commercial cuff manometers in mechanically ventilated patients. PMID:26376160
Linder, Brian J; Viers, Boyd R; Ziegelmann, Matthew J; Rivera, Marcelino E; Elliott, Daniel S
2017-01-01
To compare outcomes for single urethral cuff downsizing versus tandem cuff placement during artificial urinary sphincter (AUS) revision for urethral atrophy. We identified 1778 AUS surgeries performed at our institution from 1990-2014. Of these, 406 were first AUS revisions, including 69 revisions for urethral atrophy. Multiple clinical and surgical variables were evaluated for potential association with device outcomes following revision, including surgical revision strategy (downsizing a single urethral cuff versus placing tandem urethral cuffs). Of the 69 revision surgeries for urethral atrophy at our institution, 56 (82%) were tandem cuff placements, 12 (18%) were single cuff downsizings and one was relocation of a single cuff. When comparing tandem cuff placements and single cuff downsizings, the cohorts were similar with regard to age (p=0.98), body-mass index (p=0.95), prior pelvic radiation exposure (p=0.73) and length of follow-up (p=0.12). Notably, there was no difference in 3-year overall device survival compared between single cuff and tandem cuff revisions (60% versus 76%, p=0.94). Likewise, no significant difference was identified for tandem cuff placement (ref. single cuff) when evaluating the risk of any tertiary surgery (HR 0.95, 95% CI 0.32-4.12, p=0.94) or urethral erosion/device infection following revision (HR 0.79, 95% CI 0.20-5.22, p=0.77). There was no significant difference in overall device survival in patients undergoing single cuff downsizing or tandem cuff placement during AUS revision for urethral atrophy. Copyright® by the International Brazilian Journal of Urology.
Diagnostic imaging in uterine incisional necrosis/dehiscence complicating cesarean section.
Rivlin, Michel E; Patel, Rameshkumar B; Carroll, C Shannon; Morrison, John C
2005-12-01
To review the diagnostic imaging studies in patients with surgically proven uterine incisional necrosis/dehiscence complicating cesarean section and to compare these studies with the findings at surgery. Over a 6-year period, the records of 7 patients with imaging studies prior to surgery for uterine incisional necrosis/dehiscence complicating cesarean delivery were reviewed and compared with the findings at surgery. Four cases underwent computed tomography (CT) and sonography, 1 underwent CT only, and 2 underwent sonography only. Abnormal findings included abdominal free fluid in 4, pleural effusions in 3, dilated bowel in 3, possible bladder flap hematoma in 2 and single instances of liver abscess and retained products of conception. In no cases were all the studies normal, and necrosis/dehiscence was not demonstrated in any patient. Abdominal free fluid, bowel distension, pleural effusion and bladder flap hematoma seen on CT or sonogram in the postcesarean context suggest the possibility of uterine incisional necrosis/dehiscence. Magnetic resonance imaging (MRI) might then be indicated since MRI may be superior to CT in evaluating complications at the incisional site because of its multiplanar capability and greater degree of soft tissue contrast.
[Rotator cuff tear athropathy prevalence].
Guerra-Soriano, F; Encalada-Díaz, M I; Ruiz-Suárez, M; Valero-González, F S
2017-01-01
Glenohumeral arthritis secondary to massive rotator cuff tear presents with a superior displacement and femoralization of the humeral head with coracoacromial arch acetabularization. The purpose of this study was to establish prevalence of rotator cuff tear artropathy (CTA) at our institution. Four hundred electronic records were reviewed from which we identified 136 patients with rotator cuff tears. A second group was composed with patients with massive cuff tears that were analized and staged by the Seebauer cuff tear arthropathy classification. Thirty four patients with massive rotator cuff tears were identified, 8 male and 26 female (age 60.1 ± 10.26 years). Massive rotator cuff tear prevalence was 25%. CTA prevalence found in the rotator cuff group was 19 and 76% in the massive cuff tears group. Patients were staged according to the classification with 32% in stage 1a, 11% 1b, 32% 2a and 0% 2b. CTA prevalence in patients with rotator cuff tears and massive cuff tears is higher than the one reported in American population. We consider that a revision of the Seebauer classification to be appropriate to determine its reliability.
A mechano-acoustic model of the effect of superior canal dehiscence on hearing in chinchilla
Songer, Jocelyn E.; Rosowski, John J.
2008-01-01
Superior canal dehiscence (SCD) is a pathological condition of the ear that can cause a conductive hearing loss. The effect of SCD (a hole in the bony wall of the superior semicircular canal) on chinchilla middle- and inner-ear mechanics is analyzed with a circuit model of the dehiscence. The model is used to predict the effect of dehiscence on auditory sensitivity and mechanics. These predictions are compared to previously published measurements of dehiscence related changes in chinchilla cochlear potential, middle-ear input admittance and stapes velocity. The comparisons show that the model predictions are both qualitatively and quantitatively similar to the physiological results for frequencies where physiologic data are available. The similarity supports the third-window hypothesis of the effect of superior canal dehiscence on auditory sensitivity and mechanics and provides the groundwork for the development of a model that predicts the effect of superior canal dehiscence syndrome on auditory sensitivity and mechanics in humans. PMID:17672643
Dosimetric Effects of Air Pockets Around High-Dose Rate Brachytherapy Vaginal Cylinders
DOE Office of Scientific and Technical Information (OSTI.GOV)
Richardson, Susan, E-mail: srichardson@radonc.wustl.ed; Palaniswaamy, Geethpriya; Grigsby, Perry W.
2010-09-01
Purpose: Most physicians use a single-channel vaginal cylinder for postoperative endometrial cancer brachytherapy. Recent published data have identified air pockets between the vaginal cylinders and the vaginal mucosa. The purpose of this research was to evaluate the incidence, size, and dosimetric effects of these air pockets. Methods and Materials: 25 patients receiving postoperative vaginal cuff brachytherapy with a high-dose rate vaginal cylinders were enrolled in this prospective data collection study. Patients were treated with 6 fractions of 200 to 400 cGy per fraction prescribed at 5 mm depth. Computed tomography simulation for brachytherapy treatment planning was performed for each fraction.more » The quantity, volume, and dosimetric impact of the air pockets surrounding the cylinder were quantified. Results: In 25 patients, a total of 90 air pockets were present in 150 procedures (60%). Five patients had no air pockets present during any of their treatments. The average number of air pockets per patient was 3.6, with the average total air pocket volume being 0.34 cm{sup 3} (range, 0.01-1.32 cm{sup 3}). The average dose reduction to the vaginal mucosa at the air pocket was 27% (range, 9-58%). Ten patients had no air pockets on their first fraction but air pockets occurred in subsequent fractions. Conclusion: Air pockets between high-dose rate vaginal cylinder applicators and the vaginal mucosa are present in the majority of fractions of therapy, and their presence varies from patient to patient and fraction to fraction. The existence of air pockets results in reduced radiation dose to the vaginal mucosa.« less
The Effect of Superior Semicircular Canal Dehiscence on Intracochlear Sound Pressures
NASA Astrophysics Data System (ADS)
Nakajima, Hideko Heidi; Pisano, Dominic V.; Merchant, Saumil N.; Rosowski, John J.
2011-11-01
Semicircular canal dehiscence (SCD) is a pathological opening in the bony wall of the inner ear that can result in conductive hearing loss. The hearing loss is variable across patients, and the precise mechanism and source of variability is not fully understood. We use intracochlear sound pressure measurements in cadaveric preparations to study the effects of SCD size. Simultaneous measurement of basal intracochlear sound pressures in scala vestibuli (SV) and scala tympani (ST) quantifies the complex differential pressure across the cochlear partition, the stimulus that excites the partition. Sound-induced pressures in SV and ST, as well as stapes velocity and ear-canal pressure are measured simultaneously for various sizes of SCD followed by SCD patching. At low frequencies (<600 Hz) our results show that SCD decreases the pressure in both SV and ST, as well as differential pressure, and these effects become more pronounced as dehiscence size is increased. For frequencies above 1 kHz, the smallest pinpoint dehiscence can have the larger effect on the differential pressure in some ears. These effects due to SCD are reversible by patching the dehiscence.
Hypersensitive Ethylene Signaling and ZMdPG1 Expression Lead to Fruit Softening and Dehiscence
Li, Min; Zhang, Yanmin; Zhang, Zongying; Ji, Xiaohao; Zhang, Rui; Liu, Daliang; Gao, Liping; Zhang, Jing; Wang, Biao; Wu, Yusen; Wu, Shujing; Chen, Xiaoliu; Feng, Shouqian; Chen, Xuesen
2013-01-01
‘Taishanzaoxia’ fruit rapid softening and dehiscence during ripening stage and this process is very sensitive to endogenous ethylene. In this study, we cloned five ethylene signal transcription factors (ZMdEIL1, ZMdEIL2, ZMdEIL3, ZMdERF1 and ZMdERF2) and one functional gene, ZMdPG1, encoding polygalacturonase that could loose the cell connection which associated with fruit firmness decrease and fruit dehiscence to illustrate the reasons for this specific fruit phenotypic and physiological changes. Expression analysis showed that ZMdERF1 and ZMdEIL2 transcription were more abundant in ‘Taishanzaoxia’ softening fruit and dehiscent fruit and their expression was inhibited by an ethylene inhibitor 1-methylcyclopropene. Therefore, ZMdERF1 and ZMdEIL2 expression were responses to endogenous ethylene and associated with fruit softening and dehiscence. ZMdPG1 expression was induced when fruit softening and dehiscence but this induction can be blocked by 1-MCP, indicating that ZMdPG1 was essential for fruit softening and dehiscence and its expression was mediated by the endogenously occurred ethylene. ZMdPG1 overexpression in Arabidopsis led to silique early dehiscence while suppressing ZMdPG1 expression by antisense ZMdPG1 prevented silique naturally opening. The result also suggested that ZMdPG1 related with the connection between cells that contributed to fruit softening and dehiscence. ZMdERF1 was more closely related with ethylene signaling but it was not directly regulated the ZMdPG1, which might be regulated by the synergic pattern of ethylene transcription factors because of both the ZMdERF1 and ZMdERF2 could interact with ZMdEIL2. PMID:23527016
A new classification of post-sternotomy dehiscence
Anger, Jaime; Dantas, Daniel Chagas; Arnoni, Renato Tambellini; Farsky, Pedro Sílvio
2015-01-01
The dehiscence after median transesternal sternotomy used as surgical access for cardiac surgery is one of its complications and it increases the patient's morbidity and mortality. A variety of surgical techniques were recently described resulting to the need of a classification bringing a measure of objectivity to the management of these complex and dangerous wounds. The different related classifications are based in the primary causal infection, but recently the anatomical description of the wound including the deepness and the vertical extension showed to be more useful. We propose a new classification based only on the anatomical changes following sternotomy dehiscence and chronic wound formation separating it in four types according to the deepness and in two sub-groups according to the vertical extension based on the inferior insertion of the pectoralis major muscle. PMID:25859875
Paunović, Milorad
2013-01-01
Dehiscence after laparotomy is one of the major complications of laparotomy. This is a partial or complete wound with disruption and evisceratio abdominal organs and require urgent reintervention. The aim of this study was to determine the impact of neoplastic disease and systemic disease of connective tissue on the occurrence of dehiscence laparotomy. A prospective study were included 612 patients operated at the Clinic for General Surgery in Nis in the period from January 2009 to December 2010. The effect of neoplastic disease and the presence of systemic disease of connective tissue on the occurrence of dehiscence laparotomy. Results are displayed numerically and in percentages. Of the total 24 patients with dehiscence laparotomy, 15 patients were male or 62.5% and 9 female patients, or 37.5%. There was a statistically significant association between dehiscence laparotomy and neoplastic diseases (c2 = 42,196; p < 0.01). There was no statistically significant association between dehiscence laparo-tomy and systemic disease of connective tissue (c2 = 0,028; p > 0.05). In patients with neoplastic diseases dehis-cence laparotomy is common, and in patients suffering from systemic disease of connective tissue dehiscence laparotomy occurs less frequently.
Petersen, M; Sander, L; Child, R; van Onckelen, H; Ulvskov, P; Borkhardt, B
1996-06-01
Seven distinct partial cDNAs, similar in sequence to previously described polygalacturonases (PGs), were amplified from cDNA derived from rape pod wall, dehiscence zone and leaves by the polymerase chain reaction. Northern analysis showed that one clone, PG35-8, was expressed at low levels in the dehiscence zone during the first five weeks after anthesis but was very abundantly expressed at week 6. In contrast, no PG35-8-related RNA was detected in the pod wall. Our data suggest that there are temporal and spatial correlations between the breakdown of the middle lamella, of the dehiscence zone cells and the pattern of synthesis of PG35-8 transcripts which may indicate a role for this particular PG in rape pod dehiscence. PG35-8 was used to isolate five cDNA clones from a rape dehiscence zone cDNA library. Restriction enzyme analysis and partial sequencing revealed that they were derived from four highly homologous transcripts which are probably allelic forms of a single gene. One full-length clone, RDPG1, was completely sequenced. The predicted protein of RDPG1 showed its highest identity with PG from apple fruit with an identity of 52%.
Carotid artery protrusion and dehiscence in patients with acromegaly.
Sasagawa, Yasuo; Tachibana, Osamu; Doai, Mariko; Hayashi, Yasuhiko; Tonami, Hisao; Iizuka, Hideaki; Nakada, Mitsutoshi
2016-10-01
Acromegaly is a systemic disease which causes multiple bony alterations. Some authors reported that acromegalic patients have risk factors for an intraoperative vascular injury due to the specific anatomical features of their sphenoid sinus. The objective of our study was to analyze the anatomic characteristics of sphenoid sinus in acromegalic patients compared with controls, by evaluation of computed tomography (CT) findings. We examined 45 acromegalic (acromegaly group) and 45 non-acromegalic patients (control group) with pituitary adenomas who were matched for sex, age, height, tumor size, and cavernous sinus invasion (Knosp grade). Preoperative CT of the pituitary region including the sphenoid sinus was used to evaluate the following anatomic characteristics: type of sphenoid sinus (sellar or pre-sellar/conchal); intrasphenoid septa (non/single or multiple); carotid artery protrusion; carotid artery dehiscence; intercarotid distance. Sixteen acromegalic patients (35.5 %) and 6 controls (13.3 %) had carotid artery protrusion. Additionally, 10 acromegalic patients (22.2 %) and 3 controls (6.6 %) had carotid artery dehiscence. Carotid artery protrusion and dehiscence were more frequent in the acromegaly group than in control group (p = 0.013 and 0.035, respectively). Other anatomic characteristics (type of sphenoid sinus, intrasphenoid septa, and intracarotid distance) showed no significant differences between acromegaly and control groups. Our study suggests that carotid artery protrusion and dehiscence occur more frequently among acromegalic patients, compared with non-acromegalic patients. It is important for surgeons to be aware of these anatomic variations to avoid vital complications, such as carotid injuries, during surgery.
Poiani, Silvana B; Costa-Leonardo, Ana M
2016-03-01
During Isoptera evolution, the caste of soldiers disappeared in some Apicotermitinae termites as in the Neotropical Ruptitermes. Paired dorsolateral structures located between the metathorax and abdomen of foraging workers of Ruptitermes were previously denominated dehiscent glands, and are responsible for releasing an adhesive secretion that immobilizes enemies, causing their death. In this study, we investigated the morphology of dehiscent organs of workers of Ruptitermes reconditus, Ruptitermes xanthochiton, and Ruptitermes pitan and also second instar larvae of R. reconditus using light, laser scanning confocal, and transmission electron microscopy. Additionally, we performed a preliminary protein analysis using SDS-PAGE to further characterize the secretion of Ruptitermes dehiscent organs. Our results showed that the dehiscent organs do not exhibit the typical characteristics of the exocrine glandular cells class I, II or III of insects, suggesting that they constitute a new type of defensive organ. Thus, the denomination dehiscent gland was not used but dehiscent organ. Dehiscent organs in larvae are formed by fat body cells. In workers, dehiscent organs are composed by compact masses of cells that accumulate a defensive secretion and are poor in organelles related to the production of secretion. Since the dehiscent organs are not glands, we hypothesize that the dehiscent organs originate from larval fat body. The defensive secretion may have been produced at younger developmental stages of worker or the defensive compounds were absorbed from food and accumulated in the worker fat body. Histochemical techniques and SDS-PAGE revealed that the secretion of Ruptitermes dehiscent organs is constituted mainly by a protein of high molecular weight (200 kDa). In conclusion, the dehiscent organs are extremely different from the exocrine glands of termites and other insects described until now. In fact, they seem to be a specialized fat body that is peculiar and
2017-01-31
AFRL-SA-WP-SR-2017-0004 Correlation Between Endotracheal Tube Cuff Pressure and Tracheal Wall Pressure Using Air- and Saline -Filled...Correlation Between Endotracheal Tube Cuff Pressure and Tracheal Wall Pressure Using Air- and Saline -Filled Cuffs 5a. CONTRACT NUMBER FA8650-14...descending from altitude. When using saline in the ETT cuff, TW pressure differences with the 7.5 high-volume, low-pressure cuff and 8.0 TaperGuard
Factors affecting rotator cuff healing.
Mall, Nathan A; Tanaka, Miho J; Choi, Luke S; Paletta, George A
2014-05-07
Several studies have noted that increasing age is a significant factor for diminished rotator cuff healing, while biomechanical studies have suggested the reason for this may be an inferior healing environment in older patients. Larger tears and fatty infiltration or atrophy negatively affect rotator cuff healing. Arthroscopic rotator cuff repair, double-row repairs, performing a concomitant acromioplasty, and the use of platelet-rich plasma (PRP) do not demonstrate an improvement in structural healing over mini-open rotator cuff repairs, single-row repairs, not performing an acromioplasty, or not using PRP. There is conflicting evidence to support postoperative rehabilitation protocols using early motion over immobilization following rotator cuff repair.
Hedberg, Pia; Eklund, Carolina; Högqvist, Sandra
2015-06-01
The most common complication due to intubation is a high cuff pressure. A high cuff pressure can cause postanesthetic tracheal mucosal injuries in patients undergoing surgery. The aim of this cross-sectional study was to describe whether anesthetic nurses and anesthesiologists identified a very high cuff pressure by manual palpation of the external cuff balloon on an endotracheal tube. An airway device was intubated with an endotracheal tube cuffed to 95 cm H2O. Each participant palpated the external cuff balloon and then filled out a questionnaire, including estimation of the cuff pressure and user frequency of the cuff pressure manometer. The results showed that 89.1% estimated that the cuff pressure was high. Among the participants who rated the cuff pressure as high, 44.8% rated the pressure as quite high and 60.6% rated the pressure as very high. There was no significant relationship between profession and skill in identifying a very high cuff pressure (P = .843) or between work experience and skill in terms of identifying a very high cuff pressure (P = .816). These findings indicate that 10% of patients are at risk of tracheal erosion because of a high cuff pressure.
Effect of tracheal tube cuff shape on fluid leakage across the cuff: an in vitro study.
Dave, M H; Frotzler, A; Spielmann, N; Madjdpour, C; Weiss, M
2010-10-01
This study compared the fluid leakage in the new 'tapered' shaped against the classic 'cylindrical' shaped tracheal tube cuffs when placed in different sized tracheas. The 7.5 mm internal diameter (ID) tracheal tube cuffs-Tapered Seal Guard (TSG), Standard Seal Guard (SSG), Hi-Lo, Microcuff, Ruesch, and Portex Profile-were compared in an in vitro apparatus. Vertical artificial tracheas with 16, 20, and 22 mm ID were intubated, 5 ml clear water was applied above the unlubricated tube cuffs, and fluid leakage was measured up to 60 min. Data of tapered vs non-tapered tube cuffs (16 observations) were compared for each tracheal diameter using the Mann-Whitney test. Median (range) fluid leakage (ml) at 60 min was 2.14 (0.05-4.88), 1.14 (0.00-4.84), and 0.13 (0.00-1.32), respectively, for 16, 20, and 22 mm tracheas in the TSG tube studies when compared with 4.58 (0.44-4.88), 2.21 (0.00-4.81), and 0.00 (0.00-4.81) in the SSG tube and 4.54 (1.54-4.82), 0.90 (0.00-4.49), and 4.85 (4.40-4.99) in the Microcuff tube studies. Leakage in all polyvinylchloride (PVC) tube cuffs was almost complete (5 ml) within 5 min (P<0.001). The tapered PU tube cuff was as effective as the cylindrical PU cuffs in smaller tracheal diameters and was more efficient than the cylindrical Microcuff PU tube cuff in larger tracheal diameter in preventing subglottic fluid leakage across the tube cuff tested in this in vitro study. PVC tube cuffs leaked much more and faster than PU cuffs.
Gwak, Heui-Chul; Kim, Chang-Wan; Kim, Jung-Han; Choo, Hye-Jeung; Sagong, Seung-Yeob; Shin, John
2015-05-01
The purpose of this study was to evaluate the extension of delamination and the cuff integrity after arthroscopic repair of delaminated rotator cuff tears. Sixty-five patients with delaminated rotator cuff tears were retrospectively reviewed. The delaminated tears were divided into full-thickness delaminated tears and partial-thickness delaminated tears. To evaluate the medial extension, we calculated the coronal size of the delaminated portion. To evaluate the posterior extension, we checked the tendon involved. Cuff integrity was evaluated by computed tomography arthrography. The mean medial extension in the full-thickness and partial-thickness delaminated tears was 18.1 ± 6.0 mm and 22.7 ± 6.3 mm, respectively (P = .0084). The posterior extension into the supraspinatus and the infraspinatus was 36.9% and 32.3%, respectively, in the full-thickness delaminated tears, and it was 27.7% and 3.1%, respectively, in the partial-thickness delaminated tears (P = .0043). With regard to cuff integrity, 35 cases of anatomic healing, 10 cases of partial healing defects, and 17 cases of retear were detected. Among the patients with retear and partial healing of the defect, all the partially healed defects showed delamination. Three retear patients showed delamination, and 14 retear patients did not show delamination; the difference was statistically significant (P = .0001). The full-thickness delaminated tears showed less medial extension and more posterior extension than the partial-thickness delaminated tears. Delamination did not develop in retear patients, but delamination was common in the patients with partially healed defects. Copyright © 2015 Journal of Shoulder and Elbow Surgery Board of Trustees. Published by Elsevier Inc. All rights reserved.
Modified closure technique for reducing sternal dehiscence; a clinical and in vitro assessment.
John, Lindsay C H
2008-05-01
Although the incidence of sternal dehiscence is low its mortality can be high. An alternative technique is described (modified closure) which aims to redistribute the dehiscence force into the longer longitudinal axis rather than the shorter transverse axis, thereby maximising the closure strength. Four ethibond sutures, which interlock anteriorly, are used in addition to eight transverse sternal wires. The aim of the study was to assess the modified closure using both an in vitro and a clinical study. (a) In vitro study: A weight and traction pulley system applied a force of 0.1kN to pairs of silicone rubber hemisterna approximated to each other using alternative closure techniques. The dehiscence tendency (DT) was measured as the amount of separation under tension. Using 10 pairs of hemisterna for each closure technique the measured DT for the modified closure (MC) was compare with those for each of five alternative closures (two figure-of-eight and four transverse sutures (2C), 6 (6T), 8 (8T), 10 (10T) and 12 transverse sutures (12T)). (b) Clinical study: The incidence of sternal dehiscence for the first 4 years of a consultants' practice (using 8T) was compared with the second 4 years (using MC). (a) Measured DT (mean+/-SEM), (MC: 149+/-14; 6T: 256+/-13; 8T: 223+/-9; 10T: 213+/-13; 12T: 203+/-8; 2C: 294+/-15). DT was significantly smaller for MC (p<0.003). (b) The incidence of dehiscence was significantly smaller in the second 4 years (MC) than in the first (8T): 0.2% (1/529) versus 1.6% (13/788); p=0.01 In vitro and clinical studies suggest that the modified closure technique can reduce the incidence of sternal dehiscence.
Ghai, Babita; Sethi, Sameer; Ram, Jagat; Wig, Jyotsna
2013-02-01
Clinical end points are often used to guide inflation and adequacy of cuff seal after laryngeal mask airway placement. However, clinical end points for cuff inflation have been shown to have significantly higher intracuff pressure. The adjusted cuff pressure between 55 and 60 cm H(2)O causes significantly better seal of laryngeal mask airway. We prospectively assessed the cuff pressures generated by cuff inflation guided by clinical end points, and the actual volume of air required to achieve cuff pressures between 55 and 60 cm H(2)O for sizes 1-2.5 reusable classic laryngeal mask airway. Two hundred and three ASA I and II children undergoing elective cataract surgery requiring general anesthesia receiving laryngeal mask airway sizes 1-2.5 were recruited to this study. The laryngeal mask airway was placed using standard technique. After insertion of laryngeal mask airway, the cuff was slowly inflated until a slight outward shift of device was noted. Cuff pressures were measured using calibrated hand held Portex Cuff Inflator Pressure Gauge (Portex Limited, Hythe, Kent, UK). If the cuff pressure was >60 cm H(2)O, the cuff was deflated to achieve a cuff pressure of 55-60 cm H(2)O. The volume of air required to achieve this pressure was recorded. The volume of air required to achieve the pressure between 55 and 60 cm H(2)O in laryngeal mask airway size 1, 1.5, 2.0, and 2.5 were 2.750 ± 0.2565, 4.951 ± 0.5378, 6.927 ± 0.6328, and 10.208 ± 1.4535 ml, respectively. The difference between the initial and the final cuff volumes and pressures in all laryngeal mask airway sizes were statistically significant(P = 0.000). Lower cuff volumes are required to achieve a pressure of 60 cm H(2)O than those required if clinical end points are used as a sole guide for determining cuff inflation for patients receiving pediatric laryngeal mask airways. © 2012 Blackwell Publishing Ltd.
Frequency of Dehiscence in Hand-Sutured and Stapled Intestinal Anastomoses in Dogs.
Duell, Jason R; Thieman Mankin, Kelley M; Rochat, Mark C; Regier, Penny J; Singh, Ameet; Luther, Jill K; Mison, Michael B; Leeman, Jessica J; Budke, Christine M
2016-01-01
To determine the frequency of dehiscence of hand-sutured and stapled intestinal anastomoses in the dog and compare the surgery duration for the methods of anastomosis. Historical cohort study. Two hundred fourteen client-owned dogs undergoing hand-sutured (n = 142) or stapled (n = 72) intestinal anastomoses. Medical records from 5 referral institutions were searched for dogs undergoing intestinal resection and anastomosis between March 2006 and February 2014. Demographic data, presence of septic peritonitis before surgery, surgical technique (hand-sutured or stapled), surgery duration, surgeon (resident versus faculty member), indication for surgical intervention, anatomic location of resection and anastomosis, and if dehiscence was noted postoperatively were retrieved. Estimated frequencies were summarized and presented as proportions and 95% confidence intervals (CI) and continuous outcomes as mean (95% CI). Comparisons were made across methods of anastomosis. Overall, 29/205 dogs (0.14, 95% CI 0.10-00.19) had dehiscence, including 21/134 dogs (0.16, 0.11-0.23) undergoing hand-sutured anastomosis and 8/71 dogs (0.11, 0.06-0.21) undergoing stapled anastomosis. There was no significant difference in the frequency of dehiscence across anastomosis methods (χ(2), P = .389). The mean (95% CI) surgery duration of 140 minutes (132-147) for hand- sutured anastomoses and 108 minutes (99-119) for stapled anastomoses was significantly different (t-test, P < .001). No significant difference in frequency of dehiscence was noted between hand- sutured and stapled anastomoses in dogs but surgery duration is significantly reduced by the use of staples for intestinal closure. © Copyright 2015 by The American College of Veterinary Surgeons.
Rotator cuff crepitus: could Codman really feel a cuff tear?
Ponce, Brent A; Kundukulam, Joseph A; Sheppard, Evan D; Determann, Jason R; McGwin, Gerald; Narducci, Carl A; Crowther, Marshall J
2014-07-01
The objective of this study was to assess the accuracy of palpating crepitus to diagnose rotator cuff tears. Seventy consecutive consenting patients who presented with shoulder pain and no previous imaging or surgery on the affected shoulder were prospectively enrolled during a 10-month period. A standardized patient history and examination, including the crepitus test, were recorded in addition to obtaining standard radiographs. Additional imaging after initial evaluation was performed with magnetic resonance imaging and interpreted by a musculoskeletal radiologist blinded to the examination findings. Statistical analysis was used to determine sensitivity, specificity, positive predictive value (PPV), and negative predictive value (NPV) of the crepitus test in the clinical diagnosis of a rotator cuff tear. Sixty-three patients had histories, examinations, and imaging studies available for analysis. The crepitus test had a sensitivity of 67%, specificity of 80%, PPV of 91%, and NPV of 43% for all types of rotator cuff tears. The sensitivity and specificity for full-thickness or high-grade partial tears was 82% and 73%, respectively; the PPV and NPV were 77% and 79%. Increasing age improved accuracy as the presence of crepitus in patients older than 55 years had a sensitivity of 76%, specificity of 100%, PPV of 100%, and NPV of 38%. The crepitus test has a favorable sensitivity, specificity, PPV, and NPV to assess the integrity of the rotator cuff and may be a useful examination in the clinical diagnosis of a rotator cuff tear. Published by Mosby, Inc.
Songer, Jocelyn E.; Rosowski, John J.
2006-01-01
A superior semicircular canal dehiscence (SCD) is a break or hole in the bony wall of the superior semicircular canal. Patients with SCD syndrome present with a variety of symptoms: some with vestibular symptoms, others with auditory symptoms (including low-frequency conductive hearing loss) and yet others with both. We are interested in whether or not mechanically altering the superior canal by introducing a dehiscence is sufficient to cause the low-frequency conductive hearing loss associated with SCD syndrome. We evaluated the effect of a surgically introduced dehiscence on auditory responses to air-conducted (AC) stimuli in 11 chinchilla ears. Cochlear potential (CP) was recorded at the round-window before and after a dehiscence was introduced. In each ear, a decrease in CP in response to low frequency (<2 kHz) sound stimuli was observed after the introduction of the dehiscence. The dehiscence was then patched with cyanoacrylate glue leading to a reversal of the dehiscence-induced changes in CP. The reversible decrease in auditory sensitivity observed in chinchilla is consistent with the elevated AC thresholds observed in patients with SCD. According to the ‘third-window’ hypothesis the SCD shunts sound-induced stapes velocity away from the cochlea, resulting in decreased auditory sensitivity to AC sounds. The data collected in this study are consistent with predictions of this hypothesis. PMID:16150562
Optimized Dose Distribution of Gammamed Plus Vaginal Cylinders
DOE Office of Scientific and Technical Information (OSTI.GOV)
Supe, Sanjay S.; Bijina, T.K.; Varatharaj, C.
2009-04-01
Endometrial carcinoma is the most common malignancy arising in the female genital tract. Intracavitary vaginal cuff irradiation may be given alone or with external beam irradiation in patients determined to be at risk for locoregional recurrence. Vaginal cylinders are often used to deliver a brachytherapy dose to the vaginal apex and upper vagina or the entire vaginal surface in the management of postoperative endometrial cancer or cervical cancer. The dose distributions of HDR vaginal cylinders must be evaluated carefully, so that clinical experiences with LDR techniques can be used in guiding optimal use of HDR techniques. The aim of thismore » study was to optimize dose distribution for Gammamed plus vaginal cylinders. Placement of dose optimization points was evaluated for its effect on optimized dose distributions. Two different dose optimization point models were used in this study, namely non-apex (dose optimization points only on periphery of cylinder) and apex (dose optimization points on periphery and along the curvature including the apex points). Thirteen dwell positions were used for the HDR dosimetry to obtain a 6-cm active length. Thus 13 optimization points were available at the periphery of the cylinder. The coordinates of the points along the curvature depended on the cylinder diameters and were chosen for each cylinder so that four points were distributed evenly in the curvature portion of the cylinder. Diameter of vaginal cylinders varied from 2.0 to 4.0 cm. Iterative optimization routine was utilized for all optimizations. The effects of various optimization routines (iterative, geometric, equal times) was studied for the 3.0-cm diameter vaginal cylinder. The effect of source travel step size on the optimized dose distributions for vaginal cylinders was also evaluated. All optimizations in this study were carried for dose of 6 Gy at dose optimization points. For both non-apex and apex models of vaginal cylinders, doses for apex point and
Rehabilitation after Rotator Cuff Repair.
Nikolaidou, Ourania; Migkou, Stefania; Karampalis, Christos
2017-01-01
Rotator cuff tears are a very common condition that is often incapacitating. Whether non-surgical or surgical, successful management of rotator cuff disease is dependent on appropriate rehabilitation. If conservative management is insufficient, surgical repair is often indicated. Postsurgical outcomes for patients having had rotator cuff repair can be quite good. A successful outcome is much dependent on surgical technique as it is on rehabilitation. Numerous rehabilitation protocols for the management of rotator cuff disease are based primarily on clinical experience and expert opinion. This article describes the different rehabilitation protocols that aim to protect the repair in the immediate postoperative period, minimize postoperative stiffness and muscle atrophy. A review of currently available literature on rehabilitation after arthroscopic rotator cuff tear repair was performed to illustrate the available evidence behind various postoperative treatment modalities. There were no statistically significant differences between a conservative and an accelerated rehabilitation protocol . Early passive range of motion (ROM) following arthroscopic cuff repair is thought to decrease postoperative stiffness and improve functionality. However, early aggressive rehabilitation may compromise repair integrity. The currently available literature did not identify any significant differences in functional outcomes and relative risks of re-tears between delayed and early motion in patients undergoing arthroscopic rotator cuff repairs. A gentle rehabilitation protocol with limits in range of motion and exercise times after arthroscopic rotator cuff repair would be better for tendon healing without taking any substantial risks. A close communication between the surgeon, the patient and the physical therapy team is important and should continue throughout the whole recovery process.
Dudley, L; Kettle, C; Thomas, P W; Ismail, K M K
2017-02-10
To establish the feasibility of conducting a definitive randomised controlled trial (RCT) comparing the effectiveness of resuturing versus expectant management for dehisced perineal wounds. A multicentre pilot and feasibility RCT. Ten UK maternity units from July 2011 to July 2013. Eligible women with a dehisced perineal wound within 2 weeks of childbirth. The interventions were resuturing or expectancy. Randomisation was via web or telephone, stratified by participating centre. Blinding was not possible due to the nature of the interventions. Analysis was by intention-to-treat. The primary outcome measure was wound healing at 6-8 weeks. The study revealed a number of feasibility issues, particularly strong patient and clinician preference for treatment options at recruiting centres and the timing of the primary outcome measure. Thirty-four women were randomised (17 in each arm). Data from 33 women were analysed on an intention-to-treat analysis to obtain preliminary estimates of effect size. There was a difference in wound healing at 2 weeks favouring resuturing (OR 20.00, 95% CI 2.04 to 196.37, p=0.004). However, by 6-8 weeks all but one wound in both groups had healed. PREVIEW revealed a number of feasibility issues, which impacted on recruitment rate. These will have to be taken into account in the design of any future definitive study. In this feasibility study, resuturing was associated with quicker wound healing and women reported higher satisfaction rates with the outcome at 3 months. ISRCTN05754020. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://www.bmj.com/company/products-services/rights-and-licensing/.
Austin, Luke; Pepe, Matthew; Tucker, Bradford; Ong, Alvin; Nugent, Robert; Eck, Brandon; Tjoumakaris, Fotios
2015-06-01
Sleep disturbance is a common complaint of patients with a rotator cuff tear. Inadequate and restless sleep, along with pain, is often a driving symptom for patients to proceed with rotator cuff repair. To date, no studies have examined sleep disturbance in patients undergoing rotator cuff repair, and there is no evidence that surgery improves sleep disturbance. Sleep disturbance is prevalent in patients with a symptomatic rotator cuff tear, and sleep disturbance improves after arthroscopic rotator cuff repair. Case series; Level of evidence, 4. A total of 56 patients undergoing arthroscopic rotator cuff repair for full-thickness tears were enrolled in a prospective study. Patients were surveyed preoperatively and postoperatively at intervals of 2, 6, 12, 18, and 24 weeks. Patient outcomes were scored using the Pittsburgh Sleep Quality Index (PSQI), Simple Shoulder Test (SST), visual analog scale for pain (VAS), and single assessment numeric evaluation (SANE). Demographic and surgical factors were also collected for analysis. Preoperative PSQI scores indicative of sleep disturbance were reported in 89% of patients. After surgery, a statistically significant improvement in PSQI was achieved at 3 months (P = .0012; 91% follow-up) and continued through 6 months (P = .0179; 93% follow-up). Six months after surgery, only 38% of patients continued to have sleep disturbance. Multivariable linear regression of all surgical and demographic factors versus PSQI was performed and demonstrated that preoperative and prolonged postoperative narcotic use negatively affected sleep. Sleep disturbance is common in patients undergoing rotator cuff repair. After surgery, sleep disturbance improves to levels comparable with those of the general public. Preoperative and prolonged postoperative use of narcotic pain medication negatively affects sleep. © 2015 The Author(s).
Obesity, hypertension and home sphygmomanometer cuffs.
Akpolat, Tekin
2010-08-01
Since the increasing prevalence of obesity leads to a larger mean arm circumferences in the hypertensive population and appropriate cuff size is essential for accurate measurement of blood pressure, overweight and obese patients often require automated home sphygmomanometers with large- or extra large-sized cuffs. The aims of this study were to evaluate the information about cuff size on automated upper arm home sphygmomanometer packing boxes and compare the findings with wrist device boxes. One hundred twelve different device boxes (49 automated upper arm, 5 semi-automatic, and 58 wrist) produced by 40 manufacturers were investigated. Three different types of information were observed (written, graphical, or a combination of both). There was not any information about cuff size on 49 (44%) device boxes. Most of the information expressed on the boxes was not attractive or informative for the patients. This study showed that the information regarding cuff size on most of the device boxes was obtuse and the patients are not warned sufficiently about appropriate cuff size. Physicians and health care providers should inform and train their patients about appropriate cuff size.
Chu, Stephen J; Sarnachiaro, Guido O; Hochman, Mark N; Tarnow, Dennis P
2015-01-01
Immediate implant therapy involving implants placed into intact Type 1 extraction sockets has become a consistent clinical technique. The classification of Type 2 extraction sockets, where the mucosal tissues are present but there is a midfacial osseous dehiscence defect, has been described according to the extent of the buccal bone plate absence. The literature has offered different techniques in the treatment of Type 2 sockets; however, the extent of the defect has never been defined or delineated. In this article, the authors describe a subclassification of Type 2 sockets: Type 2A presents with a dehiscence defect roughly 5 mm to 6 mm from the free gingival margin (FGM) involving the coronal one-third of the labial bone plate; Type 2B presents with a dehiscence defect involving the middle one-third of the labial plate, approximately 7 mm to 9 mm from the FGM; and in Type 2C the dehiscence defect involves the apical one-third of the labial osseous plate roughly 10 mm or greater from the FGM. The authors also offer a protocol and technique employing immediate implant placement, guided bone regeneration, and bone graft containment with a custom two-piece healing abutment that can lead to consistent and satisfactory clinical outcomes in low-smile-line patients. The treatment protocol and sequence is outlined in a clinical case presentation involving a Type 2B socket.
Special report: Occlusive cuff controller
NASA Technical Reports Server (NTRS)
Baker, J. T.
1975-01-01
A mechanical occlusive cuff controller suitable for blood flow experiments in space shuttle flights is described. The device requires 115 volt ac power and a pressurized gas source. Two occluding cuff pressures (30 and 50 mmHg) are selectable by a switch on the front panel. A screw driver adjustment allows accurate cuff pressurization levels for under or oversized limbs. Two pressurization cycles (20 second and 2 minutes) can be selected by a front panel switch. Adjustment of the timing cycles is also available through the front panel. A pushbutton hand switch allows remote start of the cuff inflation cycle. A stop/reset switch permits early termination of the cycle and disabling of the controller to prevent inadvertent reactivation. Pressure in the cuff is monitored by a differential aneroid barometer. In addition, an electrocardiogram trigger circuit permits the initiation of the pressurization cycle by an externally supplied ECG cycle.
Wong, Chee Wai; Wong, Doric; Mathur, Ranjana
2014-01-01
A 37-year-old Bangladeshi male presented with an inferotemporal optic disk pit and serous macular detachment in the left eye. Imaging with spectral domain optical coherence tomography (OCT) revealed a multilayer macular schisis pattern with a small subfoveal outer retinal dehiscence. This case illustrates a rare phenotype of optic disk maculopathy with macular schisis and a small outer retinal layer dehiscence. Spectral domain OCT was a useful adjunct in delineating the retinal layers in optic disk pit maculopathy, and revealed a small area of outer retinal layer dehiscence that could only have been detected on high-resolution OCT. PMID:25349471
Vaginal birth after one previous caesarean section in a tertiary institution in Nigeria.
Aisien, A O; Oronsaye, A U
2004-11-01
Vaginal birth after one previous lower segment caesarean section represents one of the most significant and challenging issues in obstetric practice. A 5-year retrospective study was carried out at the University of Benin Teaching Hospital between January 1999 and December 2003, to determine the incidence, the maternal and fetal outcome following vaginal delivery after one previous caesarean section with a view to evaluating its safety and efficacy. There were 5234 deliveries, with 395 cases of one previous caesarean section, giving an incidence of 7.5%. The incidences of emergency caesarean section, elective caesarean section and spontaneous vaginal delivery following trial of vaginal delivery were 34.7%, 9.4% and 48.1%, respectively. During the study period there were 1317 cases of caesarean section, giving an incidence of 25.2% caesarean section rate. The incidence of one previous section among all caesarean section births was 30%. The major morbidity following vaginal delivery was uterine rupture with an incidence of 1.5% and hysterectomy of 0.8%. Three of the uterine ruptures occurred before admission because the patients laboured at home. One maternal death occurred as a result of uterine rupture and postpartum haemorrhage, giving a maternal mortality ratio of 19/100,000 and a case fatality rate of 0.3%. The corrected perinatal mortality rate was 15.2/1000, mainly from obstructed labour, abruptio placenta and fetal distress. Both maternal and fetal mortalities from vaginal birth after one previous section were significantly less than the respective overall maternal and fetal mortality from the institution. The 1-minute apgar score of babies delivered by elective section was significantly (P < 0.001) higher than the apgar score of babies delivered by emergency section and vaginally. There was only one patient with wound dehiscence at elective section without associated perinatal death. Vaginal delivery following caesarean section is relatively safe. However
Round window plugging in the treatment of superior semicircular canal dehiscence.
Succar, Eric F; Manickam, Periakaruppan V; Wing, Sara; Walter, Jeffrey; Greene, Joseph S; Azeredo, William J
2018-06-01
Objectives were to describe the use of round window plugging for superior semicircular canal dehiscence syndrome and review further recommendations regarding the procedure based on our experience and to compare results with recent literature on round window plugging. Retrospective case series. Fourteen patients underwent round window plugging for superior semicircular canal dehiscence at our institution from 2012 to 2015. All patients underwent the same surgical procedure. Available pre- and postoperative data were reviewed. Fourteen patient charts were reviewed. Symptoms of autophony improved in nine of 14 (64%) patients. Symptoms of pressure-induced vertigo improved in seven of 12 (58%) patients. Hennebert's sign that was positive preoperatively only improved in one of six (17%) patients. A positive preoperative vestibular evoked myogenic potential improved in only one of six (17%) patients. Six of 13 (46%) patients had increased air conduction thresholds postoperatively. Round window plugging has been described as a less-invasive treatment for patients with superior semicircular canal dehiscence. Although the procedure did benefit some of our patients, successful outcomes were not predictable. Improvement in at least one objective finding was seen in only 21% of the patients studied. Hennebert's sign and vestibular evoked myogenic potentials that were positive preoperatively only improved in 17% of patients. At our institution, round window plugging is no longer considered a reasonable treatment option for most patients with superior semicircular canal dehiscence. We recommend that further study on this topic follow a standardized pre- and postoperative assessment. 4. Laryngoscope, 128:1445-1452, 2018. © 2017 The American Laryngological, Rhinological and Otological Society, Inc.
Posterior repair with perforated porcine dermal graft.
Taylor, G Bernard; Moore, Robert D; Miklos, John R; Mattox, T Fleming
2008-01-01
To compare postoperative vaginal incision separation and healing in patients undergoing posterior repair with perforated porcine dermal grafts with those that received grafts without perforations. Secondarily, the tensile properties of the perforated and non-perforated grafts were measured and compared. This was a non-randomized retrospective cohort analysis of women with stage II or greater rectoceles who underwent posterior repair with perforated and non-perforated porcine dermal grafts (Pelvicol(TM) CR Bard Covington, GA USA). The incidence of postoperative vaginal incision separation (dehiscence) was compared. A secondary analysis to assess graft tensile strength, suture pull out strength, and flexibility after perforation was performed using standard test method TM 0133 and ASTM bending and resistance protocols. Seventeen percent of patients (21/127) who received grafts without perforations developed vaginal incision dehiscence compared to 7% (5/71) of patients who received perforated grafts (p = 0.078). Four patients with vaginal incision dehiscence with non-perforated grafts required surgical revision to facilitate healing. Neither tensile strength or suture pull out strength were significantly different between perforated and non-perforated grafts (p = 0.81, p = 0.29, respectively). There was no difference in the flexibility of the two grafts (p = 0.20). Perforated porcine dermal grafts retain their tensile properties and are associated with fewer vaginal incision dehiscences.
Severed cuff inflation tubing of endotracheal tube: A novel way to prevent cuff deflation.
Rao, Amrut K; Chaudhuri, Souvik; Joseph, Tim T; Kamble, Deependra; Gotur, Gopal; Venkatesh, Sandeep
2014-01-01
A well-secured endotracheal tube (ETT) is essential for safe anesthesia. The ETT has to be fixed with the adhesive plasters or with tie along with adhesive plasters appropriately. It is specially required in patients having beard, in intensive care unit (ICU) patients or in oral surgeries. If re-adjustment of the ETT is necessary, we should be cautious while removal of the plasters and tie, as there may be damage to the cuff inflation system. This can be a rare cause of ETT cuff leak, thus making maintenance of adequate ventilation difficult and requiring re-intubation. In a difficult airway scenario, it can be extremely challenging to re-intubate again. We report an incidence where the ETT cuff tubing was severed while attempting to re-adjust and re-fix the ETT and the patient required re-intubation. Retrospectively, we thought of and describe a safe, reliable and novel technique to prevent cuff deflation of the severed inflation tube. The technique can also be used to monitor cuff pressure in such scenarios.
Ultrasound determination of rotator cuff tear repairability
Tse, Andrew K; Lam, Patrick H; Walton, Judie R; Hackett, Lisa
2015-01-01
Background Rotator cuff repair aims to reattach the torn tendon to the greater tuberosity footprint with suture anchors. The present study aimed to assess the diagnostic accuracy of ultrasound in predicting rotator cuff tear repairability and to assess which sonographic and pre-operative features are strongest in predicting repairability. Methods The study was a retrospective analysis of measurements made prospectively in a cohort of 373 patients who had ultrasounds of their shoulder and underwent rotator cuff repair. Measurements of rotator cuff tear size and muscle atrophy were made pre-operatively by ultrasound to enable prediction of rotator cuff repairability. Tears were classified following ultrasound as repairable or irreparable, and were correlated with intra-operative repairability. Results Ultrasound assessment of rotator cuff tear repairability has a sensitivity of 86% (p < 0.0001) and a specificity of 67% (p < 0.0001). The strongest predictors of rotator cuff repairability were tear size (p < 0.001) and age (p = 0.004). Sonographic assessments of tear size ≥4 cm2 or anteroposterior tear length ≥25 mm indicated an irreparable rotator cuff tear. Conclusions Ultrasound assessment is accurate in predicting rotator cuff tear repairability. Tear size or anteroposterior tear length and age were the best predictors of repairability. PMID:27582996
An in vitro comparison of tracheostomy tube cuffs
Maguire, Seamus; Haury, Frances; Jew, Korinne
2015-01-01
Introduction The Shiley™ Flexible adult tracheostomy tube with TaperGuard™ cuff has been designed through its geometry, materials, diameter, and wall thickness to minimize micro-aspiration of fluids past the cuff and to provide an effective air seal in the trachea while also minimizing the risk of excessive contact pressure on the tracheal mucosa. The cuff also has a deflated profile that may allow for easier insertion through the stoma site. This unique design is known as the TaperGuard™ cuff. The purpose of the observational, in vitro study reported here was to compare the TaperGuard™ taper-shaped cuff to a conventional high-volume low-pressure cylindrical-shaped cuff (Shiley™ Disposable Inner Cannula Tracheostomy Tube [DCT]) with respect to applied tracheal wall pressure, air and fluid sealing efficacy, and insertion force. Methods Three sizes of tracheostomy tubes with the two cuff types were placed in appropriately sized tracheal models and lateral wall pressure was measured via pressure-sensing elements on the inner surface. Fluid sealing performance was assessed by inflating the cuffs within the tracheal models (25 cmH2O), instilling water above the cuff, and measuring fluid leakage past the cuff. To measure air leak, tubes were attached to a test lung and ventilator, and leak was calculated by subtracting the average exhaled tidal volume from the average delivered tidal volume. A tensile test machine was used to measure insertion force for each tube with the cuff deflated to simulate clinical insertion through a stoma site. Results The average pressure exerted on the lateral wall of the model trachea was lower for the taper-shaped cuff than for the cylindrical cuff under all test conditions (P<0.05). The taper-shaped cuff also demonstrated a more even, lower pressure distribution along the lateral wall of the model trachea. The average air and fluid seal performance with the taper-shaped cuff was significantly improved, when compared to the
Chien, Wade; Ravicz, Michael E.; Rosowski, John J.; Merchant, Saumil N.
2008-01-01
Objectives (1) To develop a cadaveric temporal-bone preparation to study the mechanism of hearing loss resulting from superior semicircular canal dehiscence (SCD) and (2) to assess the potential usefulness of clinical measurements of umbo velocity for the diagnosis of SCD. Background The syndrome of dehiscence of the superior semicircular canal is a clinical condition encompassing a variety of vestibular and auditory symptoms, including an air-bone gap at low frequencies. It has been hypothesized that the dehiscence acts as a “third window” into the inner ear that shunts acoustic energy away from the cochlea at low frequencies, causing hearing loss. Methods Sound-induced stapes, umbo, and round-window velocities were measured in prepared temporal bones (n = 8) using laser-Doppler vibrometry (1) with the superior semicircular canal intact, (2) after creation of a dehiscence in the superior canal, and (3) with the dehiscence patched. Clinical measurements of umbo velocity in live SCD ears (n = 29) were compared with similar data from our cadaveric temporal-bone preparations. Results An SCD caused a significant reduction in sound-induced round-window velocity at low frequencies, small but significant increases in sound-induced stapes and umbo velocities, and a measurable fluid velocity inside the dehiscence. The increase in sound-induced umbo velocity in temporal bones was also found to be similar to that measured in the 29 live ears with SCD. Conclusion Findings from the cadaveric temporal-bone preparation were consistent with the third-window hypothesis. In addition, measurement of umbo velocity in live ears is helpful in distinguishing SCD from other otologic pathologies presenting with an air-bone gap (e.g., otosclerosis). PMID:17255894
Code of Federal Regulations, 2011 CFR
2011-04-01
... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Nerve cuff. 882.5275 Section 882.5275 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES NEUROLOGICAL DEVICES Neurological Therapeutic Devices § 882.5275 Nerve cuff. (a) Identification. A nerve cuff...
Code of Federal Regulations, 2010 CFR
2010-04-01
... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Nerve cuff. 882.5275 Section 882.5275 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES NEUROLOGICAL DEVICES Neurological Therapeutic Devices § 882.5275 Nerve cuff. (a) Identification. A nerve cuff...
Makhni, Eric C; Swart, Eric; Steinhaus, Michael E; Mather, Richard C; Levine, William N; Bach, Bernard R; Romeo, Anthony A; Verma, Nikhil N
2016-09-01
To compare the cost-effectiveness within the United States health care system of arthroscopic rotator cuff repair versus reverse total shoulder arthroplasty in patients with symptomatic large and massive rotator cuff tears without cuff-tear arthropathy. An expected-value decision analysis was constructed comparing the costs and outcomes of patients undergoing arthroscopic rotator cuff repair and reverse total shoulder arthroplasty for large and massive rotator cuff tears (and excluding cases of cuff-tear arthropathy). Comprehensive literature search provided input data to extrapolate costs and health utility states for these outcomes. The primary outcome assessed was that of incremental cost-effectiveness ratio (ICER) of reverse total shoulder arthroplasty versus rotator cuff repair. For the base case, both arthroscopic rotator cuff repair and reverse total shoulder were superior to nonoperative care, with an ICER of $15,500/quality-adjusted life year (QALY) and $37,400/QALY, respectively. Arthroscopic rotator cuff repair was dominant over primary reverse total shoulder arthroplasty, with lower costs and slightly improved clinical outcomes. Arthroscopic rotator cuff repair was the preferred strategy as long as the lifetime progression rate from retear to end-stage cuff-tear arthropathy was less than 89%. However, when the model was modified to account for worse outcomes when reverse shoulder arthroplasty was performed after a failed attempted rotator cuff repair, primary reverse total shoulder had superior outcomes with an ICER of $90,000/QALY. Arthroscopic rotator cuff repair-despite high rates of tendon retearing-for patients with large and massive rotator cuff tears may be a more cost-effective initial treatment strategy when compared with primary reverse total shoulder arthroplasty and when assuming no detrimental impact of previous surgery on outcomes after arthroplasty. Clinical judgment should still be prioritized when formulating treatment plans for these
Tympanometric findings in superior semicircular canal dehiscence syndrome.
Castellucci, A; Brandolini, C; Piras, G; Modugno, G C
2013-04-01
The diagnostic role of audio-impedancemetry in superior semicircular canal dehiscence (SSCD) disease is well known. In particular, since the first reports, the presence of evoked acoustic reflexes has represented a determining instrumental exhibit in differential diagnosis with other middle ear pathologies that are responsible for a mild-low frequencies air-bone gap (ABG). Even though high resolution computed tomography (HRCT) completed by parasagittal reformatted images still represents the diagnostic gold standard, several instrumental tests can support a suspect of labyrinthine capsule dehiscence when "suggestive" symptoms occur. Objective and subjective audiometry often represents the starting point of the diagnostic course aimed at investigating the cause responsible for the so-called "intra-labyrinthine conductive hearing loss". The purpose of this study is to evaluate the role of tympanometry, in particular of the inter-aural asymmetry ratio in peak compliance as a function of different mild-low frequencies ABG on the affected side, in the diagnostic work-up in patients with unilateral SSCD. The working hypothesis is that an increase in admittance of the "inner-middle ear" conduction system due to a "third mobile window" could be detected by tympanometry. A retrospective review of the clinical records of 45 patients with unilateral dehiscence selected from a pool of 140 subjects diagnosed with SSCD at our institution from 2003 to 2011 was performed. Values of ABG amplitude on the dehiscent side and tympanometric measurements of both ears were collected for each patient in the study group (n = 45). An asymmetry between tympanometric peak compliance of the involved side and that of the contralateral side was investigated by calculating the inter-aural difference and the asymmetry ratio of compliance at the eardrum. A statistically significant correlation (p = 0.015 by Fisher's test) between an asymmetry ratio ≥ 14% in favour of the pathologic ear and an ABG
On cuff imbalance and tripolar ENG amplifier configurations.
Triantis, Iasonas F; Demosthenous, Andreas; Donaldson, Nick
2005-02-01
Electroneurogram (ENG) recording techniques benefit from the use of tripolar cuffs because they assist in reducing interference from sources outside the cuff. However, in practice the performance of ENG amplifier configurations, such as the quasi-tripole and the true-tripole, has been widely reported to be degraded due to the departure of the tripolar cuff from ideal behavior. This paper establishes the presence of cuff imbalance and investigates its relationship to cuff asymmetry, cuff end-effects and interference source proximity. The paper also presents a comparison of the aforementioned amplifier configurations with a new alternative, termed the adaptive-tripole, developed to automatically compensate for cuff imbalance. The output signal-to-interference ratio of the three amplifier configurations were compared in vivo for two interference signals (stimulus artifact and M-wave) superimposed on compound action potentials. The experiments showed (for the first time) that the two interference signals result in different cuff imbalance values. Nevertheless, even with two distinct cuff imbalances present, the adaptive-tripole performed better than the other two systems in 61.9% of the trials.
Kim, Min-Jeong; Shim, Chang-Ki; Kim, Yong-Ki; Hong, Sung-Jun; Park, Jong-Ho; Han, Eun-Jung; Kim, Seok-Cheol
2017-01-01
Seed dehiscence of ginseng (Panax ginseng C. A. Mayer) is affected by moisture, temperature, storage conditions and microbes. Several microbes were isolated from completely dehisced seed coat of ginseng cultivars, Chunpoong and Younpoong at Gumsan, Korea. We investigated the potential of five Talaromyces flavus isolates from the dehiscence of ginseng seed in four traditional stratification facilities. The isolates showed antagonistic activities against fungal plant pathogens, such as Cylindrocarpon destructans, Fusarium oxysporum, Rhizoctonia solani, Sclerotinia nivalis, Botrytis cinerea, and Phytophthora capsici. The dehiscence ratios of ginseng seed increased more than 33% by treatment of T. flavus GG01, GG02, GG04, GG12, and GG23 in comparison to control (28%). Among the treatments, the reformulating treatment of T. flavus isolates GG01 and GG04 showed the highest of stratification ratio of ginseng seed. After 16 weeks, the reformulating treatment of T. flavus isolates GG01 and GG04 significantly enhanced dehiscence of ginseng seed by about 81% compared to the untreated control. The candidate’s treatment of T. flavus GG01 and GG04 showed the highest decreasing rate of 93% in seed coat hardness for 112 days in dehiscence period. The results suggested that the pre-inoculation of T. flavus GG01 and GG04 found to be very effective applications in improving dehiscence and germination of ginseng seed. PMID:28167883
Zhang, Hualin; Gopalakrishnan, Mahesh; Lee, Plato; Kang, Zhuang; Sathiaseelan, Vythialingam
2016-09-08
The purpose of this study was to evaluate the dosimetric impact of cylinder size in high-dose-rate (HDR) vaginal cuff brachytherapy (VCBT). Sample plans of HDR VCBT in a list of cylinders ranging from 2.5 to 4 cm in diameter at 0.5 cm incre-ment were created and analyzed. The doses were prescribed either at the 0.5cm depth with 5.5 Gy for 4 fractions or at the cylinder surface with 8.8 Gy for 4 frac-tions, in various treatment lengths. A 0.5 cm shell volume called PTV_Eval was contoured for each plan and served as the target volume for dosimetric evaluation. The cumulative and differential dose volume histograms (c-DVH and d-DVH), mean doses (D-mean) and the doses covering 90% (D90), 10% (D10), and 5% (D5) of PTV_Eval were calculated. In the 0.5 cm depth regimen, the DVH curves were found to have shifted toward the lower dose zone when a larger cylinder was used, but in the surface regimen the DVH curves shifted toward the higher dose zone as the cylinder size increased. The D-means of the both regimens were between 6.9 and 7.8 Gy and dependent on the cylinder size but independent of the treatment length. A 0.5 cm variation of diameter could result in a 4% change of D-mean. Average D90s were 5.7 (ranging from 5.6 to 5.8 Gy) and 6.1 Gy (from 5.7 to 6.4 Gy), respectively, for the 0.5 cm and surface regimens. Average D10 and D5 were 9.2 and 11 Gy, respectively, for the 0.5 cm depth regimen, and 8.9 and 9.7 Gy, respectively, for the surface regimen. D-mean, D90, D10, and D5 for other prescription doses could be calculated from the lookup tables of this study. Results indicated that the cylinder size has moderate dosimetric impact, and that both regimens are comparable in dosimetric quality. © 2016 The Authors.
Almarakbi, Waleed A; Kaki, Abdullah M
2014-07-01
The main function of an endotracheal tube (ETT) cuff is to prevent aspiration. High cuff pressure is usually associated with postoperative complications. We tried to compare cuff inflation guided by pressure volume loop closure (PV-L) with those by just to seal technique (JS) and assess the postoperative incidence of sore throat, cough and hoarseness. In a prospective, randomized clinical trial, 100 patients' tracheas were intubated. In the first group (n = 50), ETT cuff inflation was guided by PV-L, while in the second group (n. = 50) the ETT cuff was inflated using the JS technique. Intracuff pressures and volumes were measured. The incidence of postoperative cuff-related complications was reported. Demographic data and durations of intubation were comparable between the groups. The use of PV-L was associated with a lesser amount of intracuff air [4.05 (3.7-4.5) vs 5 (4.8-5.5), P < 0.001] and lower cuff pressure than those in the JS group [18.25 (18-19) vs 33 (32-35), P ≤ 0.001]. The incidence of postextubation cuff-related complications was significantly less frequent among the PV-L group patients as compared with the JS group patients (P ≤ 0.009), except for hoarseness of voice, which was less frequent among the PV-L group, but not statistically significant (P ≤ 0.065). Multiple regression models for prediction of intra-cuff pressure after intubation and before extubation revealed a statistically significant association with the technique used for cuff inflation (P < 0.0001). The study confirms that PV-L-guided ETT cuff inflation is an effective way to seal the airway and associates with a lower ETT cuff pressure and lower incidence of cuff-related complications.
Moon, Hye-Sung
2018-06-01
Using the da Vinci single-site platform, surgeons can perform more minimally invasive surgery. However, surgical challenges exist due to the limitations of single-site instrumental movements. To aid in the performance of successful robotic single-site hysterectomy, a new suturing technique using the current set of limited instruments is introduced in this study. New vaginal cuff suturing techniques have been used in 55 robotic single-site hysterectomies in our institute over the past 2 years. A needle driver approach utilizing screwing and advancing the needle driver in the correct direction at an increasing angle from the transverse cuff margin with dragging and formation of an adequate loop of thread was used when suturing the vaginal cuff. Using the new vaginal suturing techniques, easy and firm vaginal cuff closure with reduced operative time relative to previous hysterectomies was achieved. The new vaginal cuff suturing techniques may convince more surgeons to perform robotic single-site hysterectomies more frequently and with greater ease. Copyright © 2018. Published by Elsevier B.V.
The minimal leak test technique for endotracheal cuff maintenance.
Harvie, D A; Darvall, J N; Dodd, M; De La Cruz, A; Tacey, M; D'Costa, R L; Ward, D
2016-09-01
Endotracheal tube (ETT) cuff pressure management is an essential part of airway management in intubated and mechanically ventilated patients. Both under- and over-inflation of the ETT cuff can lead to patient complications, with an ideal pressure range of 20-30 cmH 2 O defined. A range of techniques are employed to ensure adequate ETT cuff inflation, with little comparative data. We performed an observational cross-sectional study in a tertiary metropolitan ICU, assessing the relationship between the minimal leak test and cuff manometry. Forty-five mechanically ventilated patients, over a three-month period, had ETT cuff manometry performed at the same time as their routine cuff maintenance (minimal leak test). Bedside nurse measurements were compared with investigator measurements. At the endpoint of cuff inflation, 20 of 45 patients (44%) had cuff pressures between 20 and 30 cmH 2 O; 11 of 45 patients (24%) had cuff pressures <20 cmH 2 O; 14 of 45 patients (31%) had cuff pressures ≥30 cmH 2 O. Univariate analysis demonstrated an association between both patient obesity and female gender requiring less ETT cuff volume ( P =0.008 and P <0.001 respectively), though this association was lost on multivariate analysis. No association was demonstrated between any measured variables and cuff pressures. Inter-operator reliability in performing the minimal leak test showed no evidence of bias between nurse and investigators (Pearson coefficient = 0.897). We conclude the minimal leak test for maintenance of ETT cuffs leads to both over- and under-inflation, and alternative techniques, such as cuff manometry, should be employed.
Rothrauff, Benjamin B; Pauyo, Thierry; Debski, Richard E; Rodosky, Mark W; Tuan, Rocky S; Musahl, Volker
2017-08-01
The torn rotator cuff remains a persistent orthopedic challenge, with poor outcomes disproportionately associated with chronic, massive tears. Degenerative changes in the tissues that comprise the rotator cuff organ, including muscle, tendon, and bone, contribute to the poor healing capacity of chronic tears, resulting in poor function and an increased risk for repair failure. Tissue engineering strategies to augment rotator cuff repair have been developed in an effort to improve rotator cuff healing and have focused on three principal aims: (1) immediate mechanical augmentation of the surgical repair, (2) restoration of muscle quality and contractility, and (3) regeneration of native enthesis structure. Work in these areas will be reviewed in sequence, highlighting the relevant pathophysiology, developmental biology, and biomechanics, which must be considered when designing therapeutic applications. While the independent use of these strategies has shown promise, synergistic benefits may emerge from their combined application given the interdependence of the tissues that constitute the rotator cuff organ. Furthermore, controlled mobilization of augmented rotator cuff repairs during postoperative rehabilitation may provide mechanotransductive cues capable of guiding tissue regeneration and restoration of rotator cuff function. Present challenges and future possibilities will be identified, which if realized, may provide solutions to the vexing condition of chronic massive rotator cuff tears.
Crusher, R H
2000-07-01
Different types of rotator cuff injuries frequently present to Accident and Emergency departments and minor injury units but can be difficult to differentiate clinically. This brief case study describes the examination and diagnosis of related shoulder injuries, specifically rotator cuff tears/disruption and calcifying supraspinatus tendinitis. The relevant anatomy and current therapies for these injuries is also discussed to enable the emergency nurse practitioner to have a greater understanding of the theory surrounding their diagnosis and treatments.
Injection Therapies for Rotator Cuff Disease.
Lin, Kenneth M; Wang, Dean; Dines, Joshua S
2018-04-01
Rotator cuff disease affects a large proportion of the overall population and encompasses a wide spectrum of pathologies, including subacromial impingement, rotator cuff tendinopathy or tear, and calcific tendinitis. Various injection therapies have been used for the treatment of rotator cuff disease, including corticosteroid, prolotherapy, platelet-rich plasma, stem cells, and ultrasound-guided barbotage for calcific tendinitis. However, the existing evidence for these therapies remains controversial or sparse. Ultimately, improved understanding of the underlying structural and compositional deficiencies of the injured rotator cuff tissue is needed to identify the biological needs that can potentially be targeted with injection therapies. Copyright © 2017 Elsevier Inc. All rights reserved.
Petrillo, S; Longo, U G; Papalia, R; Denaro, V
2017-08-01
To report the outcomes and complications of reverse shoulder arthroplasty (RSA) in massive irreparable rotator cuff tears (MIRCT) and cuff tear arthropathy (CTA). A systematic review of the literature contained in Medline, Cochrane, EMBASE, Google Scholar and Ovid databases was conducted on May 1, 2016, according to PRISMA guidelines. The key words "reverse total shoulder arthroplasty" or "reverse total shoulder prostheses" with "rotator cuff tears"; "failed rotator cuff surgery"; "massive rotator cuff tears"; "irreparable rotator cuff tears"; "cuff tear arthropathy"; "outcomes"; "complications" were matched. All articles reporting outcomes and complications of RSA for the management of MIRCT or CTA were included. The comparison between preoperative and postoperative clinical scores, as well as range of motion (ROM), was performed using the Wilcoxon-Mann-Whitney test. P values lower than 0.05 were considered statistically significant. Seven articles were included in our qualitative synthesis. A statistically significant improvement in all clinical scores and ROM was found comparing the preoperative value with the postoperative value. The degrees of retroversion of the humeral stem of the RSA do not influence the functional outcomes in a statistically significant fashion. There were 17.4% of complications. The most frequent was heterotopic ossification, occurring in 6.6% of patients. Revision surgery was necessary in 7.3% of patients. RSA restores pain-free ROM and improves function of the shoulder in patients with MIRCT or CTA. However, complications occur in a high percentage of patients. The lack of level I studies limits the real understanding of the potentials and limitations of RSA for the management of MIRCT and CTA.
Rotator Cuff Injuries - Multiple Languages
... Are Here: Home → Multiple Languages → All Health Topics → Rotator Cuff Injuries URL of this page: https://medlineplus.gov/ ... V W XYZ List of All Topics All Rotator Cuff Injuries - Multiple Languages To use the sharing features ...
Wignall, Jamie R; Baines, Stephen J
2014-01-01
To evaluate the effect of cuff presence and cuff inflation on airway pressure in an inspiratory model of canine tracheostomy. Ex vivo experimental study. Cadaver tracheas from Beagle dogs were attached aborally to a vacuum. Airway pressure and flow rate was measured before and after placement of tracheostomy tubes. None. Adult uncuffed tubes and cuffed tracheostomy tubes (sizes 4, 6, 8, and 10) were placed within tracheas. Cuffs were investigated without inflation and at maximum cuff inflation. Airway pressure was measured at constant airflow rates at 30 and 60 L/min. At set flow rates, airway pressures of tracheostomy tubes were compared to the intact trachea. A size 4 uncuffed tracheostomy tube showed the lowest airway pressure and a size 4 cuffed trachestomy tube with inflation showed the highest airway pressures. For sizes 6, 8, and 10 tubes, the presence of a cuff with and without inflation significantly increased airway pressure. Inflation of a cuff always significantly increased airway pressure. Similar pressure is seen between sizes 4 and 6 uncuffed tubes. Cuffed tracheostomy tubes should not be used unless specifically indicated due to increased airway pressure. © Veterinary Emergency and Critical Care Society 2013.
Status of the contralateral rotator cuff in patients undergoing rotator cuff repair.
Ro, Kyung-Han; Park, Jong-Hoon; Lee, Soon-Hyuck; Song, Dong-Ik; Jeong, Ha-Joon; Jeong, Woong-Kyo
2015-05-01
Although the prevalence of rotator cuff tear (RCT) in the general population has been analyzed, little information is available on the status of the opposite-side rotator cuff in patients who have undergone arthroscopic rotator cuff repair. To identify the characteristics of the contralateral shoulder and to identify factors associated with RCT of the contralateral shoulder in patients who underwent surgery for symptomatic RCT. The hypothesis was that the prevalence of RCT in the contralateral shoulder would be higher in patients with increasingly larger cuff tears requiring surgical intervention. Case series; Level of evidence, 4. The study cohort consisted of 140 patients with RCT who underwent arthroscopic rotator cuff repair. Opposite-shoulder rotator cuff tendons of all patients were evaluated by ultrasonography. Demographic information and factors related to contralateral RCT were investigated, and risk factors associated with contralateral RCT were assessed. Of the 140 patients who underwent arthroscopic rotator cuff repair, 54 (38.6%) had an RCT of the contralateral shoulder. Of 51 patients with partial-thickness and small-sized full-thickness tears of the operated shoulder, 35 (68.6%) had no tears; 14 (27.5%) had partial-thickness tears; and 2 (3.9%) had small-sized full-thickness tears of the contralateral shoulder. Of 75 patients with medium-sized full-thickness tears, 43 (57.3%) had no tears; 12 (16%) had partial-thickness tears; and 20 (26.7%) had full-thickness tears of the contralateral shoulder. Of 14 patients with large to massive full-thickness tears, 8 (57.1%) had no tears; 1 (7.1%) had a partial-thickness tear; and 5 (35.7%) had full-thickness tears of the contralateral shoulder. The prevalence of RCT of the contralateral shoulder differed significantly among groups classified by tear size (P=.007). The mean American Shoulder and Elbow Surgeons score was significantly lower in the RCT than in the nontear group (55.8±16.9 vs 61.6±13.3; P=.03
Newly developed vaginal atrophy symptoms II and vaginal pH: a better correlation in vaginal atrophy?
Tuntiviriyapun, P; Panyakhamlerd, K; Triratanachat, S; Chatsuwan, T; Chaikittisilpa, S; Jaisamrarn, U; Taechakraichana, N
2015-04-01
The primary objective of this study was to evaluate the correlation among symptoms, signs, and the number of lactobacilli in postmenopausal vaginal atrophy. The secondary objective was to develop a new parameter to improve the correlation. A cross-sectional descriptive study. Naturally postmenopausal women aged 45-70 years with at least one clinical symptom of vaginal atrophy of moderate to severe intensity were included in this study. All of the objective parameters (vaginal atrophy score, vaginal pH, the number of lactobacilli, vaginal maturation index, and vaginal maturation value) were evaluated and correlated with vaginal atrophy symptoms. A new parameter of vaginal atrophy, vaginal atrophy symptoms II, was developed and consists of the two most bothersome symptoms (vaginal dryness and dyspareunia). Vaginal atrophy symptoms II was analyzed for correlation with the objective parameters. A total of 132 naturally postmenopausal women were recruited for analysis. Vaginal pH was the only objective parameter found to have a weak correlation with vaginal atrophy symptoms (r = 0.273, p = 0.002). The newly developed vaginal atrophy symptoms II parameter showed moderate correlation with vaginal pH (r = 0.356, p < 0.001) and a weak correlation with the vaginal atrophy score (r = 0.230, p < 0.001). History of sexual intercourse within 3 months was associated with a better correlation between vaginal atrophy symptoms and the objective parameters. Vaginal pH was significantly correlated with vaginal atrophy symptoms. The newly developed vaginal atrophy symptoms II was associated with a better correlation. The vaginal atrophy symptoms II and vaginal pH may be better tools for clinical evaluation and future study of the vaginal ecosystem.
Rotator cuff tear measurement by arthropneumotomography
DOE Office of Scientific and Technical Information (OSTI.GOV)
Kilcoyne, R.F.; Matsen, F.A. III
1983-02-01
Five years of experience with a method of shoulder arthrography using upright tomography in cases of suspected or known rotator cuff tears has demonstrated its effectiveness. The value of the procedure lies in its ability to demonstrate the size of the cuff tear and the thickness of the remaining cuff tissue. This information provides the surgeon with a preoperative estimate of the difficulty of the repair and the prognosis for a good functional recovery. In 33 cases, there was good correlation between the upright thin-section tomogram findings and the surgical results. The tomograms provided better information about the size ofmore » the tear and the quality of the remaining cuff than did plain arthrograms.« less
Pauna, Henrique F.; Monsanto, Rafael C.; Schachern, Patricia A.; Costa, Sady S.; Kwon, Geeyoun; Paparella, Michael M.; Cureoglu, Sebahattin
2016-01-01
Objective Endoscopic procedures are becoming common in middle ear surgery. Inflammation due to chronic ear disease can cause bony erosion of the carotid artery and Fallopian canals, making them more vulnerable during surgery. The objective of this study was to determine whether or not chronic ear disease increases dehiscence of the carotid artery and Fallopian canals. Design Comparative human temporal bone study. Setting Otopathology laboratory. Participants We selected 78 temporal bones from 55 deceased donors with chronic otitis media or cholesteatoma, and then compared those 2 groups with a control group of 27 temporal bones from 19 deceased donors with no middle ear disease. Main outcome measures We analyzed the middle ear, carotid artery canal, and Fallopian canal, looking for signs of dehiscence of its bony coverage, using light microscopy. Results We found an increased incidence in dehiscence of the carotid artery and Fallopian canals in temporal bones with chronic middle ear disease. The size of the carotid artery canal dehiscence was larger in the middle ear diseased groups, and its bony coverage, when present, was also thinner compared to the control group. Dehiscence of the carotid artery canal was more frequently located closer to the promontory. The incidence of Fallopian canal dehiscence was significantly higher in temporal bones from donors older than 18 years with chronic middle ear disease. Conclusion The increased incidence of the carotid artery and Fallopian canal dehiscence in temporal bones with chronic middle ear disease elevates the risk of adverse events during middle ear surgery. Level of Evidence N/A. PMID:27455393
21 CFR 870.1120 - Blood pressure cuff.
Code of Federal Regulations, 2013 CFR
2013-04-01
... 21 Food and Drugs 8 2013-04-01 2013-04-01 false Blood pressure cuff. 870.1120 Section 870.1120...) MEDICAL DEVICES CARDIOVASCULAR DEVICES Cardiovascular Diagnostic Devices § 870.1120 Blood pressure cuff. (a) Identification. A blood pressure cuff is a device that has an inflatable bladder in an inelastic...
21 CFR 870.1120 - Blood pressure cuff.
Code of Federal Regulations, 2012 CFR
2012-04-01
... 21 Food and Drugs 8 2012-04-01 2012-04-01 false Blood pressure cuff. 870.1120 Section 870.1120...) MEDICAL DEVICES CARDIOVASCULAR DEVICES Cardiovascular Diagnostic Devices § 870.1120 Blood pressure cuff. (a) Identification. A blood pressure cuff is a device that has an inflatable bladder in an inelastic...
21 CFR 870.1120 - Blood pressure cuff.
Code of Federal Regulations, 2014 CFR
2014-04-01
... 21 Food and Drugs 8 2014-04-01 2014-04-01 false Blood pressure cuff. 870.1120 Section 870.1120...) MEDICAL DEVICES CARDIOVASCULAR DEVICES Cardiovascular Diagnostic Devices § 870.1120 Blood pressure cuff. (a) Identification. A blood pressure cuff is a device that has an inflatable bladder in an inelastic...
21 CFR 870.1120 - Blood pressure cuff.
Code of Federal Regulations, 2011 CFR
2011-04-01
... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Blood pressure cuff. 870.1120 Section 870.1120...) MEDICAL DEVICES CARDIOVASCULAR DEVICES Cardiovascular Diagnostic Devices § 870.1120 Blood pressure cuff. (a) Identification. A blood pressure cuff is a device that has an inflatable bladder in an inelastic...
Soderberg, S F
1986-05-01
Chronic vaginitis is the most common vaginal disorder. Dogs with vaginitis show no signs of systemic illness but often lick at the vulva and have purulent or hemorrhagic vaginal discharges. Vaginitis is most commonly secondary to a noninfectious inciting factor such as congenital vaginal anomalies, clitoral hypertrophy, foreign bodies, trauma to the vaginal mucosa, or vaginal tumors. Inspection of the caudal vagina and vestibule both visually and digitally will often reveal the source of vaginal irritation. Vaginal cytology is used to establish the stage of the estrous cycle as well as distinguish uterine from vaginal sources of discharge. Vaginal cultures are used to establish the predominant offending organism associated with vaginal discharges and may be used as a guide for selection of a therapeutic agent. Vaginitis is best managed by removing the inciting cause and treating the area locally with antiseptic douches. Congenital malformations at the vestibulovaginal or vestibulovulvar junction may prevent normal intromission. Affected bitches may be reluctant to breed naturally because of pain. Such defects are detected best by digital examination. Congenital vaginal defects may be corrected by digital or surgical means. Prolapse of tissue through the lips of the vulva may be caused by clitoral hypertrophy, vaginal hyperplasia, or vaginal tumors. Enlargement of clitoral tissue is the result of endogenous or exogenous sources of androgens. Treatment of this condition includes removal of the androgen source and/or surgical removal of clitoral tissue. Vaginal hyperplasia is detected during proestrus or estrus of young bitches. Hyperplastic tissue will regress during diestrus. Tissue that is excessively traumatized and/or prolapse of the entire vaginal circumference may be removed surgically. Ovariohysterectomy may be used to prevent recurrence. Vaginal tumors are detected most often in older intact bitches. Such tumors are generally of smooth muscle or fibrous
Rotator Cuff Deficient Arthritis of the Glenohumeral Joint
Macaulay, Alec A.; Greiwe, R. Michael
2010-01-01
Rotator cuff deficient arthritis of the glenohumeral joint, especially cuff tear arthropathy, has proved a challenging clinical entity for orthopaedic surgeons ever since Charles Neer originally detailed the problem in 1983. Understanding has improved regarding the pathophysiology and pathomechanics underlying cuff tear arthropathy. Surgical reconstruction options can lead to excellent outcomes for patients afflicted with these painful and functionally limited shoulders. Humeral hemiarthroplasty and reverse total shoulder arthroplasty have jumped to the forefront in the treatment of cuff tear arthropathy. As studies continue to look at the results of these procedures in cuff tear arthropathy, existing indications and treatment algorithms will be further refined. In this article the history and pathophysiology of cuff tear arthropathy are reviewed. Additionally, the clinical findings and results of surgical reconstruction are discussed. PMID:21119934
Ang, Benjamin Fu Hong; Chen, Jerry Yongqiang; Yeo, William; Lie, Denny Tijauw Tjoen; Chang, Paul Chee Cheng
2018-01-01
The aim of our study is to compare the improvement in clinical outcomes after conventional arthroscopic double-row rotator cuff repair and arthroscopic undersurface rotator cuff repair. A consecutive series of 120 patients who underwent arthroscopic rotator cuff repair was analysed. Sixty-one patients underwent conventional double-row rotator cuff repair and 59 patients underwent undersurface rotator cuff repair. Several clinical outcomes, including numerical pain rating scale (NPRS), constant shoulder score (CSS), Oxford shoulder score (OSS) and University of California Los Angeles shoulder score (UCLASS), were prospectively recorded by a trained healthcare professional preoperatively and at 3, 6, 12 and 24 months after surgery. Comparing both groups, there were no differences in age, gender and preoperative NPRS, CSS, OSS and UCLASS. However, the tear size was 0.7 ± 0.2 (95% confidence interval (CI) 0.3-1.1) cm larger in the conventional group ( p = 0.002). There was no difference in the improvement of NPRS, CSS, OSS and UCLASS at all time points of follow-up, that is, at 3, 6, 12 and 24 months after surgery. The duration of operation was shorter by 35 ± 3 (95% CI 28-42) min in the undersurface group ( p < 0.001). Both arthroscopic undersurface rotator cuff repair and conventional arthroscopic double-row rotator cuff repair showed marked improvements in clinical scores when compared preoperatively, and there was no difference in improvements between both groups. Arthroscopic undersurface rotator cuff repair is a faster technique compared to the conventional arthroscopic double-row rotator cuff repair.
Hu, Chen; Gong, Ting; Lin, Weimin; Yuan, Quan; Man, Yi
2017-10-01
To evaluate bone reconstruction and soft tissue reactions at immediate implants placed into intact sockets and those with buccal bone dehiscence defects. Fifty-nine internal connection implants from four different manufacturers were immediately placed in intact sockets(non-dehiscence group, n=40), and in alveoli with buccal bone dehiscence defects: 1) Group 1(n= N10), the defect depth measured 3-5 mm from the gingival margin. 2) Group 2(n=9), the depth ranged from 5mm to 7mm. The surrounding bony voids were grafted with deproteinized bovine bone mineral (DBBM) particles. Cone beam computed tomography(CBCT) was performed immediately after surgery (T1), and at 6 months later(T2). Radiographs were taken at prosthesis placement and one year postloading(T3). Soft tissue parameters were measured at baseline (T0), prosthesis placement and T3. No implants were lost during the observation period. For the dehiscence groups, the buccal bone plates were radiographically reconstructed to comparable horizontal and vertical bone volumes compared with the non-dehiscence group. Marginal bone loss occurred between the time of final restoration and 1-year postloading was not statistically different(P=0.732) between groups. Soft tissue parameters did not reveal inferior results for the dehiscence groups. Within the limitations of this study, flapless implant placement into compromised sockets in combination with DBBM grafting may be a viable technique to reconstitute the defected buccal bone plates due to space maintenance and primary socket closure provided by healing abutments and bone grafts. Immediate implants and DBBM grafting without using membranes may be indicated for sockets with buccal bone defects. Copyright © 2017 Elsevier Ltd. All rights reserved.
Automated control of endotracheal tube cuff pressure during simulated flight.
Blakeman, Thomas; Rodriquez, Dario; Woods, James; Cox, Daniel; Elterman, Joel; Branson, Richard
2016-11-01
Successful mechanical ventilation requires that the airway be controlled by an endotracheal tube (ETT) with an inflatable cuff to seal the airway. Aeromedical evacuation represents a unique challenge in which to manage ETT cuffs. We evaluated three methods of automatic ETT cuff pressure adjustment during changes in altitude in an altitude chamber. Size 7.5 and 8.0 mm ETTs that are currently included in the Critical Care Air Transport Team allowance standard were used for the evaluation. Three automatic cuff pressure controllers-Intellicuff, Hamilton Medical; Pyton, ARM Medical; and Cuff Sentry, Outcome Solutions-were used to manage cuff pressures. The fourth group had cuff pressure set at sea level without further adjustment. Each ETT was inserted into a tracheal model and taken to 8,000 feet and then to 16,000 feet at 2,500 ft/min. Baseline cuff pressure at sea level was approximately 25 cm H2O. Mean cuff pressure at both altitudes with both size ETTs was as follows: Control arm, 141 ± 64 cm H2O; Pyton, 25 ± 0.8 cm H2O; Cuff Sentry, 22 ± 0.3 cm H2O; and Intellicuff, 29 ± 6.6 cm H2O. The mean time that cuff pressure was >30 cm H2O using Intellicuff at both altitudes was 2.8 ± 0.8 minutes. Pressure differences from baseline in the control arm and with Intellicuff were statistically significant. Cuff pressure with the Cuff Sentry tended to be lower than indicated on the device. Mean cuff pressures were within the recommended range with all three devices. Intellicuff had difficulty regulating the cuff pressure initially with increases in altitude but was able to reduce the pressure to a safe level during the stabilization period at each altitude. The Pyton and Cuff Sentry allowed the least variation in pressure throughout the evaluation, although the Cuff Sentry set pressure was less than the actual pressure. Therapeutic study, level V.
Vaginal toxic shock reaction triggering desquamative inflammatory vaginitis.
Pereira, Nigel; Edlind, Thomas D; Schlievert, Patrick M; Nyirjesy, Paul
2013-01-01
The study aimed to report 2 cases of desquamative inflammatory vaginitis associated with toxic shock syndrome toxin 1 (TSST-1)-producing Staphylococcus aureus strains. Case report of 2 patients, 1 with an acute and 1 with a chronic presentation, diagnosed with desquamative inflammatory vaginitis on the basis of clinical findings and wet mount microscopy. Pretreatment and posttreatment vaginal bacterial and yeast cultures were obtained. Pretreatment vaginal bacterial cultures from both patients grew TSST-1-producing S. aureus. Subsequent vaginal bacterial culture results after oral antibiotic therapy were negative. Desquamative inflammatory vaginitis may be triggered through TSST-1-mediated vaginal toxic shock reaction.
[Shoulder instability and rotator cuff tear].
Voigt, C; Lill, H
2009-01-01
A rotator cuff tear as a complication of anterior shoulder dislocation is well known in patients over 40 years old. The incidence of this accompanying injury correlates with the patient's age and the number of redislocations. The tear localization and dimension depend on the patient's age. To what extent these tears are a complication of shoulder dislocation is often unclear, as rotator cuff tears and glenohumeral instability interact. Reports on this combined injury pattern are rare, but based on the patient's age, activity level, and functional demand, therapeutic concepts have been devised. In active patients younger than 60 years and in cases of redislocation, both the rotator cuff tear and the capsule-labrum-ligament lesion should be reconstructed arthroscopically. In lesser active patients age 60 years or older, an isolated rotator cuff reconstruction is often sufficient to stabilize the glenohumeral joint. This treatment concept shows a predominantly good outcome.As a special form of anterior shoulder dislocation, a rotator cuff tear and a plexus brachialis lesion--the"terrible triad of the shoulder"--is described here.
Composition of Muscle Fiber Types in Rat Rotator Cuff Muscles.
Rui, Yongjun; Pan, Feng; Mi, Jingyi
2016-10-01
The rat is a suitable model to study human rotator cuff pathology owing to the similarities in morphological anatomy structure. However, few studies have reported the composition muscle fiber types of rotator cuff muscles in the rat. In this study, the myosin heavy chain (MyHC) isoforms were stained by immunofluorescence to show the muscle fiber types composition and distribution in rotator cuff muscles of the rat. It was found that rotator cuff muscles in the rat were of mixed fiber type composition. The majority of rotator cuff fibers labeled positively for MyHCII. Moreover, the rat rotator cuff muscles contained hybrid fibers. So, compared with human rotator cuff muscles composed partly of slow-twitch fibers, the majority of fast-twitch fibers in rat rotator cuff muscles should be considered when the rat model study focus on the pathological process of rotator cuff muscles after injury. Gaining greater insight into muscle fiber types in rotator cuff muscles of the rat may contribute to elucidate the mechanism of pathological change in rotator cuff muscles-related diseases. Anat Rec, 299:1397-1401, 2016. © 2016 Wiley Periodicals, Inc. © 2016 Wiley Periodicals, Inc.
Jaradat, Masrur R; Ruegger, Max; Bowling, Andrew; Butler, Holly; Cutler, Adrian J
2014-01-01
Asynchronous flowering of Brassica napus (canola) leads to seeds and siliques at varying stages of maturity as harvest approaches. This range of maturation can result in premature silique dehiscence (pod shattering), resulting in yield losses, which may be worsened by environmental stresses. Therefore, a goal for canola crop improvement is to reduce shattering in order to maximize yield. We performed a comprehensive transcriptome analysis on the dehiscence zone (DZ) and valve of Arabidopsis and Brassica siliques in shatter resistant and sensitive genotypes at several developmental stages. Among known Arabidopsis dehiscence genes, we confirmed that homologs of SHP1/2, FUL, ADPG1, NST1/3 and IND were associated with shattering in B. juncea and B. napus. We noted a correlation between reduced pectin degradation genes and shatter-resistance. Tension between lignified and non-lignified cells in the silique DZ plays a major role in dehiscence. Light microscopy revealed a smaller non-lignified separation layer in relatively shatter-resistant B. juncea relative to B. napus and this corresponded to increased expression of peroxidases involved in monolignol polymerization. Sustained repression of auxin biosynthesis, transport and signaling in B. juncea relative to B. napus may cause differences in dehiscence zone structure and cell wall constituents. Tension on the dehiscence zone is a consequence of shrinkage and loss of flexibility in the valves, which is caused by senescence and desiccation. Reduced shattering was generally associated with upregulation of ABA signaling and down-regulation of ethylene and jasmonate signaling, corresponding to more pronounced stress responses and reduced senescence and photosynthesis. Overall, we identified 124 cell wall related genes and 103 transcription factors potentially involved in silique dehiscence.
Jaradat, Masrur R; Ruegger, Max; Bowling, Andrew; Butler, Holly; Cutler, Adrian J
2014-01-01
Asynchronous flowering of Brassica napus (canola) leads to seeds and siliques at varying stages of maturity as harvest approaches. This range of maturation can result in premature silique dehiscence (pod shattering), resulting in yield losses, which may be worsened by environmental stresses. Therefore, a goal for canola crop improvement is to reduce shattering in order to maximize yield. We performed a comprehensive transcriptome analysis on the dehiscence zone (DZ) and valve of Arabidopsis and Brassica siliques in shatter resistant and sensitive genotypes at several developmental stages. Among known Arabidopsis dehiscence genes, we confirmed that homologs of SHP1/2, FUL, ADPG1, NST1/3 and IND were associated with shattering in B. juncea and B. napus. We noted a correlation between reduced pectin degradation genes and shatter-resistance. Tension between lignified and non-lignified cells in the silique DZ plays a major role in dehiscence. Light microscopy revealed a smaller non-lignified separation layer in relatively shatter-resistant B. juncea relative to B. napus and this corresponded to increased expression of peroxidases involved in monolignol polymerization. Sustained repression of auxin biosynthesis, transport and signaling in B. juncea relative to B. napus may cause differences in dehiscence zone structure and cell wall constituents. Tension on the dehiscence zone is a consequence of shrinkage and loss of flexibility in the valves, which is caused by senescence and desiccation. Reduced shattering was generally associated with upregulation of ABA signaling and down-regulation of ethylene and jasmonate signaling, corresponding to more pronounced stress responses and reduced senescence and photosynthesis. Overall, we identified 124 cell wall related genes and 103 transcription factors potentially involved in silique dehiscence. PMID:25523176
Lansley, J A; Tucker, W; Eriksen, M R; Riordan-Eva, P; Connor, S E J
2017-09-01
Pulsatile tinnitus is experienced by most patients with idiopathic intracranial hypertension. The pathophysiology remains uncertain; however, transverse sinus stenosis and sigmoid sinus diverticulum/dehiscence have been proposed as potential etiologies. We aimed to determine whether the prevalence of transverse sinus stenosis and sigmoid sinus diverticulum/dehiscence was increased in patients with idiopathic intracranial hypertension and pulsatile tinnitus relative to those without pulsatile tinnitus and a control group. CT vascular studies of patients with idiopathic intracranial hypertension with pulsatile tinnitus ( n = 42), without pulsatile tinnitus ( n = 37), and controls ( n = 75) were independently reviewed for the presence of severe transverse sinus stenosis and sigmoid sinus diverticulum/dehiscence according to published criteria. The prevalence of transverse sinus stenosis and sigmoid sinus diverticulum/dehiscence in patients with idiopathic intracranial hypertension with pulsatile tinnitus was compared with that in the nonpulsatile tinnitus idiopathic intracranial hypertension group and the control group. Further comparisons included differing degrees of transverse sinus stenosis (50% and 75%), laterality of transverse sinus stenosis/sigmoid sinus diverticulum/dehiscence, and ipsilateral transverse sinus stenosis combined with sigmoid sinus diverticulum/dehiscence. Severe bilateral transverse sinus stenoses were more frequent in patients with idiopathic intracranial hypertension than in controls ( P < .001), but there was no significant association between transverse sinus stenosis and pulsatile tinnitus within the idiopathic intracranial hypertension group. Sigmoid sinus dehiscence (right- or left-sided) was also more common in patients with idiopathic intracranial hypertension compared with controls ( P = .01), but there was no significant association with pulsatile tinnitus within the idiopathic intracranial hypertension group. While our data
Partial Thickness Rotator Cuff Tears: Current Concepts
Matthewson, Graeme; Beach, Cara J.; Nelson, Atiba A.; Woodmass, Jarret M.; Ono, Yohei; Boorman, Richard S.; Lo, Ian K. Y.; Thornton, Gail M.
2015-01-01
Partial thickness rotator cuff tears are a common cause of pain in the adult shoulder. Despite their high prevalence, the diagnosis and treatment of partial thickness rotator cuff tears remains controversial. While recent studies have helped to elucidate the anatomy and natural history of disease progression, the optimal treatment, both nonoperative and operative, is unclear. Although the advent of arthroscopy has improved the accuracy of the diagnosis of partial thickness rotator cuff tears, the number of surgical techniques used to repair these tears has also increased. While multiple repair techniques have been described, there is currently no significant clinical evidence supporting more complex surgical techniques over standard rotator cuff repair. Further research is required to determine the clinical indications for surgical and nonsurgical management, when formal rotator cuff repair is specifically indicated and when biologic adjunctive therapy may be utilized. PMID:26171251
Current Biomechanical Concepts for Rotator Cuff Repair
2013-01-01
For the past few decades, the repair of rotator cuff tears has evolved significantly with advances in arthroscopy techniques, suture anchors and instrumentation. From the biomechanical perspective, the focus in arthroscopic repair has been on increasing fixation strength and restoration of the footprint contact characteristics to provide early rehabilitation and improve healing. To accomplish these objectives, various repair strategies and construct configurations have been developed for rotator cuff repair with the understanding that many factors contribute to the structural integrity of the repaired construct. These include repaired rotator cuff tendon-footprint motion, increased tendon-footprint contact area and pressure, and tissue quality of tendon and bone. In addition, the healing response may be compromised by intrinsic factors such as decreased vascularity, hypoxia, and fibrocartilaginous changes or aforementioned extrinsic compression factors. Furthermore, it is well documented that torn rotator cuff muscles have a tendency to atrophy and become subject to fatty infiltration which may affect the longevity of the repair. Despite all the aforementioned factors, initial fixation strength is an essential consideration in optimizing rotator cuff repair. Therefore, numerous biomechanical studies have focused on elucidating the strongest devices, knots, and repair configurations to improve contact characteristics for rotator cuff repair. In this review, the biomechanical concepts behind current rotator cuff repair techniques will be reviewed and discussed. PMID:23730471
Passive contribution of the rotator cuff to abduction and joint stability.
Tétreault, Patrice; Levasseur, Annie; Lin, Jenny C; de Guise, Jacques; Nuño, Natalia; Hagemeister, Nicola
2011-11-01
The purpose of this study is to compare shoulder joint biomechanics during abduction with and without intact non-functioning rotator cuff tissue. A cadaver model was devised to simulate the clinical findings seen in patients with a massive cuff tear. Eight full upper limb shoulder specimens were studied. Initially, the rotator cuff tendons were left intact, representing a non-functional rotator cuff, as seen in suprascapular nerve paralysis or in cuff repair with a patch. Subsequently, a massive rotator cuff tear was re-created. Three-dimensional kinematics and force requirements for shoulder abduction were analyzed for each condition using ten abduction cycles in the plane of the scapula. Mediolateral displacements of the glenohumeral rotation center (GHRC) during abduction with an intact non-functioning cuff were minimal, but massive cuff tear resulted in significant lateral displacement of the GHRC (p < 0.013). Similarly, massive cuff tear caused increased superior migration of the GHRC during abduction compared with intact non-functional cuff (p < 0.01). From 5 to 30° of abduction, force requirements were significantly less with an intact non-functioning cuff than with massive cuff tear (p < 0.009). During abduction, an intact but non-functioning rotator cuff resulted in decreased GHRC displacement in two axes as well as lowered the force requirement for abduction from 5 to 30° as compared with the results following a massive rotator cuff tear. This provides insight into the potential biomechanical effect of repairing massive rotator cuff tears with a biological or synthetic "patch," which is a new treatment for massive cuff tear.
Non-specific vaginitis or vaginitis of undetermined aetiology.
Faro, S; Phillips, L E
1987-01-01
Vaginitis is a complex syndrome that is probably the most common outpatient disease seen by the gynaecologist. The specific aetiologies of vaginitis are many. One of the most common entities, however, is "non-specific vaginitis" which can be subdivided into: Gardnerella vaginitis, anaerobic vaginosis, and vaginitis of undetermined aetiology. The role of Gardnerella as a causative agent for vaginitis has been studied in depth but its specific role remains controversial. Anaerobic vaginosis can be diagnosed by noting on microscopic examination the presence of clue cells, free-floating bacteria and numerous white blood cells (WBC's). Culturing an aliquot of the vaginal discharge reveals a high number of anaerobes. In addition, this condition responds to antibiotics effective against anaerobes, e.g., metronidazole. Vaginitis of undetermined aetiology is more complex and is characterized by a purulent vaginal discharge, a pH of 4.0-4.6, numerous WBC's, and a high concentration of bacteria. The microbiology of this vaginitis includes many facultative Gram-negative rods and Gram-positive cocci. Anaerobes may be present but do not make up a large component of the endogenous microflora. This condition does not respond to the usual antibiotic therapies employed in treating bacterial vaginitis. Since this condition appears to be primarily an inflammatory reaction, it may be responsive to topical antiinflammatory agents such as benzydamine.
Vaginal cancer; Cancer - vagina; Tumor - vaginal ... Most vaginal cancers occur when another cancer, such as cervical or endometrial cancer , spreads. This is called secondary vaginal cancer. Cancer ...
Zheng, Dingchang; Pan, Fan; Murray, Alan
2013-10-01
The aim of this study was to investigate the effect of different mechanical behaviour of the brachial artery on blood pressure (BP) measurements during cuff inflation and deflation. BP measurements were taken from each of 40 participants, with three repeat sessions under three randomized cuff deflation/inflation conditions. Cuff pressure was linearly deflated and inflated at a standard rate of 2-3 mmHg/s and also linearly inflated at a fast rate of 5-6 mmHg/s. Manual auscultatory systolic and diastolic BPs, and pulse pressure (SBP, DBP, PP) were measured. Automated BPs were determined from digitally recorded cuff pressures by fitting a polynomial model to the oscillometric pulse amplitudes. The BPs from cuff deflation and inflation were then compared. Repeatable measurements between sessions and between the sequential order of inflation/deflation conditions (all P > 0.1) indicated stability of arterial mechanical behaviour with repeat measurements. Comparing BPs obtained by standard inflation with those from standard deflation, manual SBP was 2.6 mmHg lower (P < 0.01), manual DBP was 1.5 mmHg higher (P < 0.01), manual PP was 4.2 mmHg lower (P < 0.001), automated DBP was 6.7 mmHg higher (P < 0.001) and automatic PP was 7.5 mmHg lower (P < 0.001). There was no statistically significant difference for any automated BPs between fast and standard cuff inflation. The statistically significant BP differences between inflation and deflation suggest different arterial mechanical behaviour between arterial opening and closing during BP measurement. We have shown that the mechanical behaviour of the brachial artery during BP measurement differs between cuff deflation and cuff inflation.
Indications for reverse total shoulder arthroplasty in rotator cuff disease.
Drake, Gregory N; O'Connor, Daniel P; Edwards, T Bradley
2010-06-01
Reverse total shoulder arthroplasty (RTSA) was introduced to treat rotator cuff tear arthropathy but is now used to treat a variety of problems. Although its use has expanded substantially since the FDA's approval in 2004, the appropriateness in patients with rotator cuff disease is unclear. We review the use of RTSA in patients with rotator cuff disease to (1) describe classification of rotator cuff tear reparability and the concept of a balanced shoulder; (2) explore the theory behind RTSA design relative to rotator cuff arthropathy; (3) discuss the indications and contraindications for RTSA; and (4) review published outcomes of RTSA for rotator cuff arthropathy. We performed a selective review of the literature on the use of RTSA in the treatment of rotator cuff disease. Modern RTSA designs restore deltoid tension and a functional fulcrum to the rotator cuff deficient shoulder, which allows recovery of active shoulder elevation and effectively restores function in short- and medium-term followup studies. In short-term followup the RTSA relieves symptoms and restores function for patients with cuff tear arthropathy and irreparable rotator cuff tears with pseudoparalysis (preserved deltoid contraction but loss of active elevation). Severely impaired deltoid function, an isolated supraspinatus tear, and the presence of full active shoulder elevation with a massive rotator cuff tear and arthritis are contraindications to RTSA. For properly selected patients who have symptomatic and disabling rotator cuff deficiency, RTSA can result in life-changing improvements in pain, motion, function, and patient satisfaction. Level V therapeutic study. See Guidelines for Authors for a complete description of levels of evidence.
Three-Dimensional Printed Prosthesis for Repair of Superior Canal Dehiscence.
Kozin, Elliott D; Remenschneider, Aaron K; Cheng, Song; Nakajima, Hideko Heidi; Lee, Daniel J
2015-10-01
Outcomes following repair of superior canal dehiscence (SCD) are variable, and surgery carries a risk of persistent or recurrent SCD symptoms, as well as a risk of hearing loss and vestibulopathy. Poor outcomes may occur from inadequate repair of the SCD or mechanical insult to the membranous labyrinth. Repair of SCD using a customized, fixed-length prosthesis may address current operative limitations and improve surgical outcomes. We aim to 3-dimensionally print customized prostheses to resurface or occlude bony SCD defects. Dehiscences were created along the arcuate eminence of superior semicircular canals in cadaveric temporal bones. Prostheses were designed and created using computed tomography and a 3-dimensional printer. The prostheses occupied the superior semicircular canal defect, reflected in postrepair computed tomography scans. This novel approach to SCD repair could have advantages over current techniques. Refinement of prosthesis design and materials will be important if this approach is translated into clinical use. © American Academy of Otolaryngology-Head and Neck Surgery Foundation 2015.
Rhee, Yong Girl; Cho, Nam Su; Song, Jong Hoon; Park, Jung Gwan; Kim, Tae Yong
2017-09-01
If the balance of the rotator cuff force couple is disrupted, pseudoparalysis may occur, but the exact mechanism remains unknown. This study investigated the effect of rotator cuff force couple disruption on active range of motion in massive rotator cuff tear (mRCT) by rotator cuff muscle volume analysis. The study included 53 patients with irreparable mRCT: 22 in the nonpseudoparalysis group and 31 in the pseudoparalysis group. The volumes of the subscapularis (SBS), infraspinatus (ISP), and teres minor (TM) muscles were measured using magnetic resonance imaging (MRI), and the ratios of each muscle volume to the anatomic external rotator (aER) volume were calculated. A control group of 25 individuals with normal rotator cuffs was included. Anterior-to-posterior cuff muscle volume ratio (SBS/ISP + TM) was imbalanced in both mRCT groups (1.383 nonpseudoparalysis and 1.302 pseudoparalysis). Between the 2 groups, the ISP/aER ratio (0.277 vs. 0.249) and the inferior SBS/aER ratio (0.426 vs. 0.390) were significantly decreased in the pseudoparalysis group (P= .022 and P= .040, respectively). However, neither the TM/aER ratio (0.357 vs. 0.376) nor the superior SBS/aER ratio (0.452 vs. 0.424) showed a significant difference between the two groups (P= .749 and P= .068, respectively). If the inferior SBS was torn, a high frequency of pseudoparalysis was noted (81.0%, P= .010). The disruption of transverse force couple was noted in both irreparable mRCT groups, although no significant difference was found between the nonpseudoparalysis and pseudoparalysis groups. ISP and inferior SBS muscle volumes showed a significant decrease in pseudoparalysis group and, therefore, were considered to greatly influence the loss of active motion in mRCT. The TM did not exert significant effect on the incidence of pseudoparalysis. Copyright © 2017 Journal of Shoulder and Elbow Surgery Board of Trustees. Published by Elsevier Inc. All rights reserved.
... an Endocrinologist Search Featured Resource Menopause Map™ View Vaginal Atrophy October 2017 Download PDFs English Editors Christine ... during this time, including vaginal dryness. What is vaginal atrophy? Vaginal atrophy (also referred to as vulvovaginal ...
Saline-filled cuffs help prevent laser-induced polyvinylchloride endotracheal tube fires.
Sosis, M B; Dillon, F X
1991-02-01
To determine whether the filling of tracheal tube cuffs with saline would decrease their combustibility during laser surgery, 20 polyvinylchloride tracheal tubes were studied. The cuffed end of each tracheal tube was inserted into the neck of an empty flask, and the tube and flask were flushed with oxygen for 5 min before cuff inflation. Ten tracheal tubes had their cuffs inflated with air, and 10 were inflated with saline. A Lasersonics LS880 CO2 laser, set to 5 W for five of each of the two types of filled cuffs and to 40 W for the other pair of five tubes, was fired continuously at the cuffs for up to 1 min. No combustion occurred at the 5-W setting. The times to cuff perforation when the laser was set at 5 W were (mean +/- SD) 1.00 +/- 0.83 and 4.21 +/- 3.91 s for the air- and saline-filled cuffs, respectively, a difference that was not statistically significant. The time to deflation of the saline-filled cuff (104.6 +/- 67.5 s) was, however, significantly longer than that of the air-filled cuff (2.59 +/- 1.97 s). When the tracheal tube cuffs were exposed to 40-W laser radiation, the cuff and adjacent tube shaft ignited in all cases when the cuffs were inflated with air, but only in one of five cases when the cuffs were filled with saline (P less than 0.05). The filling of tracheal tube cuffs with saline provides simple, moderately effective partial protection of the cuff of endotracheal tubes during CO2 laser airway surgery.
Charmoy, Alexia; Würzner, Grégoire; Ruffieux, Christiane; Hasler, Christopher; Cachat, François; Waeber, Bernard; Burnier, Michel
2007-10-01
Cuff inflation at the arm is known to cause an instantaneous rise in blood pressure, which might be due to the discomfort of the procedure and might interfere with the precision of the blood pressure measurement. In this study, we compared the reactive rise in blood pressure induced by cuff inflation when the cuff was placed at the upper arm level and at the wrist. The reactive rise in systolic and diastolic blood pressure to cuff inflation was measured in 34 normotensive participants and 34 hypertensive patients. Each participant was equipped with two cuffs, one around the right upper arm (OMRON HEM-CR19, 22-32 cm) and one around the right wrist (OMRON HEM-CS 19, 17-22 cm; Omron Health Care Europe BV, Hoofddorp, The Netherlands). The cuffs were inflated in a double random order (maximal cuff pressure and position of the cuff) with two maximal cuff pressures: 180 and 240 mmHg. The cuffs were linked to an oscillometric device (OMRON HEM 907; Omron Health Care). Simultaneously, blood pressure was measured continuously at the middle finger of the left hand using photoplethysmography. Three measurements were made at each level of blood pressure at the arm and at the wrist, and the sequence of measurements was randomized. In normotensive participants, no significant difference was observed in the reactive rise in blood pressure when the cuff was inflated either at the arm or at the wrist irrespective of the level of cuff inflation. Inflating a cuff at the arm, however, induced a significantly greater rise in blood pressure than inflating it at the wrist in hypertensive participants for both systolic and diastolic pressures (P<0.01), and at both levels of cuff inflation. The blood pressure response to cuff inflation was independent of baseline blood pressure. The results show that in hypertensive patients, cuff inflation at the wrist produces a smaller reactive rise in blood pressure. The difference between the arm and the wrist is independent of the patient's level of
Kim, Jong Ok; Lee, Jong-Ho; Kim, Kwang-Sup; Ji, Jong-Hun; Koh, Sung-Jun; Lee, Jae-Ho
2017-11-01
This study investigated the efficacy of the bridging repair using an acellular dermal matrix (ADM) and an ADM with stem cells in rabbits. Also investigated were clinical outcomes of ADM bridging repair for large to massive rotator cuff tears. ADM, with and without stem cells, was used to cover a 5- × 5-mm-sized cuff defect in 17 rabbits, and biomechanical, histologic, and immunohistochemical analyses were conducted. Also evaluated were 24 patients with large to massive rotator cuff tears after ADM bridging repair. In the biomechanical test, the normal rotator cuff, cuff with ADM plus stem cells, and cuff with ADM in the rabbit model showed a maximum load (N) of 287.3, 217.5, and 170.3 and ultimate tensile strength (N/mm 2 ) of 11.1, 8.0, and 5.2, respectively. Histologically, the cuff tendons with the ADM or ADM plus stem cells showed characteristically mature tendons as time passed. In the clinical study, the mean American Shoulder and Elbow Surgeons score improved from preoperative 50 to postoperative 83, the University of California Los Angeles Shoulder Rating Scale from 17 to 30, and the Simple Shoulder Test from 4 to 8, respectively. No further fatty deteriorations or muscle atrophy were observed on follow-up magnetic resonance imaging. A retear was found in 5 of 24 patients (21%). Bridging repair with ADM or stem cells in the rabbit model showed cellular infiltration into the graft and some evidence of neotendon formation. Clinically, ADM repair was a safe alternative that did not show any further fatty deterioration nor muscle atrophy in large to massive rotator cuff tears. Copyright © 2017 Journal of Shoulder and Elbow Surgery Board of Trustees. Published by Elsevier Inc. All rights reserved.
Factors predicting rotator cuff retears: an analysis of 1000 consecutive rotator cuff repairs.
Le, Brian T N; Wu, Xiao L; Lam, Patrick H; Murrell, George A C
2014-05-01
The rate of retears after rotator cuff repair varies from 11% to 94%. A retear is associated with poorer subjective and objective clinical outcomes than intact repair. This study was designed to determine which preoperative and/or intraoperative factors held the greatest association with retears after arthroscopic rotator cuff repair. Cohort study; Level of evidence, 3. This study retrospectively evaluated 1000 consecutive patients who had undergone a primary rotator cuff repair by a single surgeon using an arthroscopic inverted-mattress knotless technique and who had undergone an ultrasound evaluation 6 months after surgery to assess repair integrity. Exclusion criteria included previous rotator cuff repair on the same shoulder, incomplete repair, and repair using a synthetic polytetrafluoroethylene patch. All patients had completed the modified L'Insalata Questionnaire and underwent a clinical examination before surgery. Measurements of tear size, tear thickness, associated shoulder injury, tissue quality, and tendon mobility were recorded intraoperatively. The overall retear rate at 6 months after surgery was 17%. Retears occurred in 27% of full-thickness tears and 5% of partial-thickness tears (P < .0001). The best independent predictors of retears were anteroposterior tear length (correlation coefficient r = 0.41, P < .0001), tear size area (r = 0.40, P < .0001), mediolateral tear length (r = 0.34, P < .0001), tear thickness (r = 0.29, P < .0001), age at surgery (r = 0.27, P < .0001), and operative time (r = 0.18, P < .0001). These factors produced a predictive model for retears: logit P = (0.039 × age at surgery in years) + (0.027 × tear thickness in %) + (1 × anteroposterior tear length in cm) + (0.76 × mediolateral tear length in cm) - (0.17 × tear size area in cm(2)) + (0.018 × operative time in minutes) -9.7. Logit P can be transformed into P, which is the chance of retears at 6 months after surgery. A rotator cuff retear is a multifactorial process
Schröder, Femke F; Huis In't Veld, Rianne; den Otter, Lydia A; van Raak, Sjoerd M; Ten Haken, Bennie; Vochteloo, Anne J H
2018-04-01
The rate of retear after rotator cuff surgery is 17%. Magnetic resonance imaging (MRI) scans are used for confirmative diagnosis of retear. However, because of the presence of titanium suture anchors, metal artefacts on the MRI are common. The present study evaluated the diagnostic value of MRI after rotator cuff tendon surgery with respect to assessing the integrity as well as the degeneration and atrophy of the rotator cuff tendons when titanium anchors are in place. Twenty patients who underwent revision surgery of the rotator cuff as a result of a clinically suspected retear between 2013 and 2015 were included. The MRI scans of these patients were retrospectively analyzed by four specialized shoulder surgeons and compared with intra-operative findings (gold standard). Sensitivity and interobserver agreement among the surgeons in assessing retears as well as the Goutallier and Warner classification were examined. In 36% (range 15% to 50%) of the pre-operative MRI scans, the observers could not review the rotator cuff tendons. When the rotator cuff tendons were assessable, a diagnostic accuracy with a mean sensitivity of 0.84 (0.70 to 1.0) across the surgeons was found, with poor interobserver agreement (kappa = 0.12). Metal artefacts prevented accurate diagnosis from MRI scans of rotator cuff retear in 36% of the patients studied.
Vaginal health in contraceptive vaginal ring users - A review.
Lete, Iñaki; Cuesta, María C; Marín, Juan M; Guerra, Sandra
2013-08-01
To provide an overview of the available data from clinical studies of vaginal conditions in women who use a vaginal ring as a contraceptive. A systematic review of the literature. Millions of women have already used the ethylene vinyl acetate vaginal ring that releases ethinylestradiol and etonogestrel for contraception. Because of its small size, more than four out of five women using the ring report that they do not feel it, even during sexual intercourse. No colposcopic or cytological changes have been observed in users, although approximately 10% have increased vaginal discharge. While in vitro studies have shown adhesion of Candida yeasts to the vaginal ring surface, clinical studies have not demonstrated a greater incidence of Candida infections compared to users of equivalent oral contraceptives. Some clinical studies suggest a lower incidence of bacterial vaginosis. No interaction exists between concomitant use of the vaginal ring and other drugs or products for vaginal use. The use of a contraceptive vaginal ring does not alter the vaginal ecosystem and therefore does not substantially affect vaginal health.
Recurrent rotator cuff tear: is ultrasound imaging reliable?
Gilat, Ron; Atoun, Ehud; Cohen, Ornit; Tsvieli, Oren; Rath, Ehud; Lakstein, Dror; Levy, Ofer
2018-02-02
The diagnostic workup of the painful shoulder after rotator cuff repair (RCR) can be quite challenging. The aim of this study was to assess the reliability of ultrasonography (US) for the detection of recurrent rotator cuff tears in patients with shoulder pain after RCR. We hypothesized that US for the diagnosis of recurrent rotator cuff tear after RCR would not prove to be reliable when compared with surgical arthroscopic confirmation (gold standard). In this cohort study (diagnosis), we retrospectively analyzed the data of 39 patients with shoulder pain after arthroscopic RCR who had subsequently undergone US, followed by revision arthroscopy. The rotator cuff was evaluated first using US for the presence of retears. Thereafter, revision arthroscopy was performed, and the diagnosis was either established or disproved. The sensitivity and specificity of US were assessed in reference to revision arthroscopy (gold standard). A rotator cuff retear was indicated by US in 21 patients (54%) and by revision arthroscopy in 26 patients (67%). US showed a sensitivity of 80.8% and specificity of 100% in the diagnosis of rotator cuff retears. Omission of partial rotator cuff retears resulted in a spike in sensitivity to 94.7%, with 100% specificity remaining. US imaging is a highly sensitive and specific test for the detection of recurrent rotator cuff tears, as confirmed by revision arthroscopy, in patients with a painful shoulder after primary RCR. Copyright © 2017 Journal of Shoulder and Elbow Surgery Board of Trustees. Published by Elsevier Inc. All rights reserved.
Hunter, Jacob B; O'Connell, Brendan P; Wang, Jianing; Chakravorti, Srijata; Makowiec, Katie; Carlson, Matthew L; Dawant, Benoit; McCaslin, Devin L; Noble, Jack H; Wanna, George B
2016-09-01
To correlate objective measures of vestibular and audiometric function as well as subjective measures of dizziness handicap with the surface area of the superior canal dehiscence (SCD). Retrospective chart review and radiological analysis. Single tertiary academic referral center. Preoperative computed tomography imaging, patient survey, audiometric thresholds, and vestibular evoked myogenic potential (VEMP) testing in patients with confirmed SCD. Image analysis techniques were developed to measure the surface area of each SCD in computed tomography imaging. Preoperative ocular and cervical VEMPs, air and bone conduction thresholds, air-bone gap, dizziness handicap inventory scores, and surface area of the SCD. Fifty-three patients (mean age 52.7 yr) with 84 SCD were analyzed. The median surface area of dehiscence was 1.44 mm (0.068-8.23 mm). Ocular VEMP amplitudes (r = 0.61, p <0.0001), cervical VEMP amplitudes (r = 0.62, p <0.0001), air conduction thresholds at 250 Hz (r = 0.25, p = 0.043), and air-bone gap at 500 Hz (r = 0.27, p = 0.01) positively correlated with increasing size of dehiscence. An inverse relationship between cervical VEMP thresholds (r = -0.56, p < 0.0001) and surface area of the dehiscence was observed. No association between dizziness handicap and surface area was identified. Among patients with confirmed SCD, ocular and cervical VEMP amplitudes, cervical VEMP thresholds, and air conduction thresholds at 250 Hz are significantly correlated with the surface area of the dehiscence.
Watson, Sheri; Aguas, Marita; Bienapfl, Tracy; Colegrove, Pat; Foisy, Nancy; Jondahl, Bonnie; Yosses, Mary Beth; Yu, Larissa; Anastas, Zoe
2011-06-01
The purpose of this study was to determine if blood pressure (BP) measured in the forearm or with an extra-long BP cuff in the upper arm accurately reflects BP measured in the upper arm with an appropriately sized BP cuff in patients with large upper arm circumference. A method-comparison design was used with a convenience sample of 49 PACU patients. Noninvasive blood pressures were obtained in two different locations (forearm; upper arm) and in the upper arm with an extra-long adult and recommended large adult cuff sizes. Data were analyzed by calculating bias and precision for the BP cuff size and location and Student's t-tests, with P < .0125 considered significant. Significantly higher forearm systolic (P < .0001) and diastolic (P < .0002) BP measurements were found compared to BP obtained in the upper arm with the reference standard BP cuff. Significantly higher systolic (t(48df) = 5.38, P < .0001), but not diastolic (t(48df) = 4.11, P < .019), BP differences were found for BP measured with the extra-long cuff at the upper arm site compared to the upper arm, reference standard BP. Findings suggest that the clinical practice of using the forearm or an extra-long cuff in the upper arm for BP measurement in post anesthesia patients with large upper arm circumferences may result in inaccurate BP values. Copyright © 2011 American Society of PeriAnesthesia Nurses. Published by Elsevier Inc. All rights reserved.
Gellhorn, Alfred C; Gillenwater, Cody; Mourad, Pierre D
2015-09-01
The objective of this preliminary study was to evaluate the ability of individual 0.1-s long pulses of intense focused ultrasound (iFU) emitted with a carrier frequency of 2 MHz to evoke diagnostic sensations when applied to patients whose shoulders have rotator cuff tears or tendinopathy. Patients were adults with painful shoulders and clinical and imaging findings consistent with rotator cuff disease. iFU stimulation of the shoulder was performed using B-mode ultrasound coupled with a focused ultrasound transducer that allowed image-guided delivery of precisely localized pulses of energy to different anatomic areas around the rotator cuff. The main outcome measure was iFU spatial average-temporal average intensity (I_SATA), and location required to elicit sensation. In control patients, iFU produced no sensation throughout the range of stimulation intensities (≤2000 W/cm(2) I_SATA). In patients with rotator cuff disease, iFU was able to induce sensation in the tendons of the rotator cuff, the subacromial bursa, and the subchondral bone in patients with chronic shoulder pain and rotator cuff disease, with an average ± standard deviation intensity equaling 680 ± 281 W/cm(2) I_SATA. This result suggests a primary role for these tissues in the pathogenesis of shoulder pain related to rotator cuff tendinopathy. Copyright © 2015 World Federation for Ultrasound in Medicine & Biology. Published by Elsevier Inc. All rights reserved.
Superior glenoid inclination and rotator cuff tears.
Chalmers, Peter N; Beck, Lindsay; Granger, Erin; Henninger, Heath; Tashjian, Robert Z
2018-03-23
The objectives of this study were to determine whether glenoid inclination (1) could be measured accurately on magnetic resonance imaging (MRI) using computed tomography (CT) as a gold standard, (2) could be measured reliably on MRI, and (3) whether it differed between patients with rotator cuff tears and age-matched controls without evidence of rotator cuff tears or glenohumeral osteoarthritis. In this comparative retrospective radiographic study, we measured glenoid inclination on T1 coronal MRI corrected into the plane of the scapula. We determined accuracy by comparison with CT and inter-rater reliability. We compared glenoid inclination between patients with full-thickness rotator cuff tears and patients aged >50 years without evidence of a rotator cuff tear or glenohumeral arthritis. An a priori power analysis determined adequate power to detect a 2° difference in glenoid inclination. (1) In a validation cohort of 37 patients with MRI and CT, the intraclass correlation coefficient was 0.877, with a mean difference of 0° (95% confidence interval, -1° to 1°). (2) For MRI inclination, the inter-rater intraclass correlation coefficient was 0.911. (3) Superior glenoid inclination was 2° higher (range, 1°-4°, P < .001) in the rotator cuff tear group of 192 patients than in the control cohort of 107 patients. Glenoid inclination can be accurately and reliably measured on MRI. Although superior glenoid inclination is statistically greater in those with rotator cuff tears than in patients of similar age without rotator cuff tears or glenohumeral arthritis, the difference is likely below clinical significance. Copyright © 2018 Journal of Shoulder and Elbow Surgery Board of Trustees. Published by Elsevier Inc. All rights reserved.
Analysis of Vaginal Cell Populations during Experimental Vaginal Candidiasis
Fidel, Paul L.; Luo, Wei; Steele, Chad; Chabain, Joseph; Baker, Marc; Wormley, Floyd
1999-01-01
Studies with an estrogen-dependent murine model of vaginal candidiasis suggest that local cell-mediated immunity (CMI) is more important than systemic CMI for protection against vaginitis. The present study, however, showed that, compared to uninfected mice, little to no change in the percentage or types of vaginal T cells occurred during a primary vaginal infection or during a secondary vaginal infection where partial protection was observed. Furthermore, depletion of polymorphonuclear leukocytes (PMN) had no effect on infection in the presence or absence of pseudoestrus. These results indicate a lack of demonstrable effects by systemic CMI or PMN against vaginitis and suggest that if local T cells are important, they are functioning without showing significant increases in numbers within the vaginal mucosa during infection. PMID:10338532
Sarnachiaro, Guido O; Chu, Stephen J; Sarnachiaro, Evangelina; Gotta, Sergio Luis; Tarnow, Dennis P
2016-08-01
To measure the buccal plate reconstruction of extraction sockets with labial plate dehiscence defects using a bone allograft in combination with an absorbable collagen membrane and a custom-healing abutment at the time of tooth removal. Ten patients underwent immediate implant placement and reconstruction of the buccal plate. Cone beam computed tomography (CBCT) was performed preextraction, immediately after bone grafting and implant placement (day 0), and between 6 and 9 months following implant surgery. Measurements were taken at three levels: coronal (L1), middle (L2), and apical (L3) level. Implants placed into sockets with labial plate dehiscence defects demonstrated radiographic reformation of the labial plate dehiscence defect at 6 to 9 months posttreatment. The net gain in labial plate on cone beam computerized tomography (CBCT) in L1 and L2 was 3.0 mm, where 0 mm existed at pretreatment. The minimum amount of labial plate thickness of 2.0 mm was achieved in all treated sites, evaluated radiographically at 6 to 9 months postoperatively, in a single procedure, without flap elevation and maintaining the gingival architecture and satisfactory esthetics. Placing an absorbable membrane, bone graft, and custom-healing abutment at the time of flapless anterior tooth extraction and immediate implant placement into a socket with a labial osseous dehiscence is a viable clinical technique to reconstitute the absence of the labial bone plate. © 2015 Wiley Periodicals, Inc.
Vaginal Toxic Shock Reaction Triggering Desquamative Inflammatory Vaginitis
Pereira, Nigel; Edlind, Thomas D.; Schlievert, Patrick M.; Nyirjesy, Paul
2012-01-01
Objective To report two cases of desquamative inflammatory vaginitis (DIV) associated with toxic shock syndrome toxin-1 (TSST-1)-producing Staphylococcus aureus strains. Materials and Methods Case report of two patients, one with an acute and one with a chronic presentation, diagnosed with DIV on the basis of clinical findings and wet mount microscopy. Pre- and posttreatment vaginal bacterial and yeast cultures were obtained. Results Pretreatment vaginal bacterial cultures from both patients grew TSST-1-producing S. aureus. Subsequent vaginal bacterial cultures following oral antibiotic therapy were negative. Conclusions DIV may be triggered through TSST-1-mediated vaginal toxic shock reaction. PMID:23222054
The Repaired Rotator Cuff: MRI and Ultrasound Evaluation.
Lee, Susan C; Williams, Danielle; Endo, Yoshimi
2018-03-01
The purposes of this review were to provide an overview of the current practice of evaluating the postoperative rotator cuff on imaging and to review the salient imaging findings of the normal and abnormal postoperative rotator cuff, as well as of postoperative complications. The repaired rotator cuff frequently appears abnormal on magnetic resonance imaging (MRI) and ultrasound (US). Recent studies have shown that while the tendons typically normalize, they can demonstrate clinically insignificant abnormal imaging appearances for longer than 6 months. Features of capsular thickening or subacromial-subdeltoid bursal thickening and fluid distension were found to decrease substantially in the first 6-month postoperative period. MRI and US were found to be highly comparable in the postoperative assessment of the rotator cuff, although they had a lower sensitivity for partial thickness tears. Imaging evaluation of newer techniques such as patch augmentation and superior capsular reconstruction needs to be further investigated. MRI and US are useful in the postoperative assessment of the rotator cuff, not only for evaluation of the integrity of the rotator cuff, but also for detecting hardware complications and other etiologies of shoulder pain.
Mechanisms of rotator cuff tendinopathy: intrinsic, extrinsic, or both?
Seitz, Amee L; McClure, Philip W; Finucane, Sheryl; Boardman, N Douglas; Michener, Lori A
2011-01-01
The etiology of rotator cuff tendinopathy is multi-factorial, and has been attributed to both extrinsic and intrinsic mechanisms. Extrinsic factors that encroach upon the subacromial space and contribute to bursal side compression of the rotator cuff tendons include anatomical variants of the acromion, alterations in scapular or humeral kinematics, postural abnormalities, rotator cuff and scapular muscle performance deficits, and decreased extensibility of pectoralis minor or posterior shoulder. A unique extrinsic mechanism, internal impingement, is attributed to compression of the posterior articular surface of the tendons between the humeral head and glenoid and is not related to subacromial space narrowing. Intrinsic factors that contribute to rotator cuff tendon degradation with tensile/shear overload include alterations in biology, mechanical properties, morphology, and vascularity. The varied nature of these mechanisms indicates that rotator cuff tendinopathy is not a homogenous entity, and thus may require different treatment interventions. Treatment aimed at addressing mechanistic factors appears to be beneficial for patients with rotator cuff tendinopathy, however, not for all patients. Classification of rotator cuff tendinopathy into subgroups based on underlying mechanism may improve treatment outcomes. 2010 Elsevier Ltd. All rights reserved.
Assessment and treatment strategies for rotator cuff tears
Al-Hakim, Wisam; Noorani, Ali
2014-01-01
Tears of the rotator cuff are common and becoming an increasingly frequent problem. There is a vast amount of literature on the merits and limitations of the various methods of clinical and radiological assessment of rotator cuff tears. This is also the case with regard to treatment strategies. Certain popular beliefs and principles practiced widely and the basis upon which they are derived may be prone to inaccuracy. We provide an overview of the historical management of rotator cuff tears, as well as an explanation for how and why rotator cuff tears should be managed, and propose a structured methodology for their assessment and treatment. PMID:27582960
Complicated sternal dehiscence: reconstruction with plates, cables, and cannulated screws.
Voss, Bernhard; Bauernschmitt, Robert; Brockmann, Gernot; Krane, Markus; Will, Albrecht; Lange, Rüdiger
2009-04-01
Sternal dehiscence after median sternotomy can be a challenging problem in case of multiple fractures or infection. For sternal refixation, the principles of rigid plate and screw osteosynthesis gained from orthopedic surgery have been recommended by several authors. We present a new system for sternal reconstruction consisting of reconstruction plates, steel cables, and cannulated screws.
Marwah, Sanjay; Marwah, Nisha; Singh, Mandeep; Kapoor, Ajay; Karwasra, Rajender Kumar
2005-02-01
The incidence of fascial dehiscence and incisional hernia after two methods for abdominal wound closure (rectus sheath relaxation incisions and conventional mass closure) was studied in a randomized prospective clinical trial in a consecutive series of 100 patients undergoing midline laparotomy for peritonitis. The two groups were well matched for etiologies of peritonitis, the surgical procedures performed, and the presence of known risk factors for fascial dehiscence. Fifty patients each were randomized either to the conventional continuous mass closure procedure or the rectus sheath relaxation incision technique (designed to increase wound elasticity and decrease tension in the suture line) using identical polypropylene sutures. The incidence of postoperative complications such as duration of ileus, chest infection, and wound infection were not statistically different between the two groups. The intensity of postoperative pain in the rectus sheath relaxation incision group was significantly less. The incidence of wound hematoma was significantly increased in the rectus sheath relaxation incision group. The incidences of fascial dehiscence (16% vs,28%; p < 0.05) and incisional hernia (18% vs, 30%; p < 0.05) were significantly lower after rectus sheath relaxation incisions compared to conventional mass closure. Closure of the midline laparotomy wound in cases of peritonitis using the rectus sheath relaxation technique is safe and less painful, provides increased wound elasticity and decreased tension on the suture line, and significantly decreases the incidence of wound dehiscence.
Clinical evaluation of stethoscope-guided inflation of tracheal tube cuffs.
Kumar, R D C; Hirsch, N P
2011-11-01
Tracheal tube cuffs are commonly inflated to pressures exceeding the recommended upper limit of 30 cmH(2)O. We evaluated whether a stethoscope-guided method of cuff inflation results in pressures within the recommended range. Patients were randomly assigned to receive one of two methods of cuff inflation. In the standard 'just seal' group, air was introduced into the tracheal cuff until the audible leak at the mouth disappeared. In the stethoscope-guided group, air was introduced into the cuff until a change from harsh to soft breath sounds occurred, whilst listening with a stethoscope bell placed over the thyroid cartilage. Twenty-five patients were recruited to each group. The median (IQR [range]) cuff pressure in the 'just seal' group was 34 (28-40 [18-49]) cmH(2)O, and in the stethoscope-guided group was 20 (20-26 [16-28]) cmH(2)O, p < 0.0001. The stethoscope-guided method of tracheal tube cuff inflation is a novel, simple technique that reliably results in acceptable tracheal cuff pressures. © 2011 The Authors. Anaesthesia © 2011 The Association of Anaesthetists of Great Britain and Ireland.
Lewis, P; Naqvi, S; Mandal, P; Potluri, P
2015-06-01
Sphygmomanometer cuff pressure during deflation is assumed to equal systolic arterial pressure at the point of resumption of flow. Previous studies demonstrated that pressure decreases with increasing depth of soft tissues whilst visco-elastic characteristics of the arm tissue cause spatial and temporal variation in pressure magnitude. These generally used non-anatomical axisymmetrical arm simulations without incorporating arterial pressure variation. We used data from a volunteer's Magnetic Resonance (MR) arm scan and investigated the effect of variations in cuff materials and construction on the simulated transmission of pressure from under the cuff to the arterial wall under sinusoidal flow conditions. Pressure was measured under 8 different cuffs using Oxford Pressure Monitor Sensors placed at 90 degrees around the mid upper arm of a healthy male. Each cuff was inflated 3 times to 155 mmHg and then deflated to zero with 90 seconds between inflations. Young's modulus, flexural rigidity and thickness of each cuff was measured.Using DICOM data from the MR scan of the arm, a 3D model was derived using ScanIP and imported into Abaqus for Finite Element Analysis (FEA). Published mechanical properties of arm tissues and geometric non-linearity were assumed. The measured sub-cuff pressures were applied to the simulated arm and pressure was calculated around the brachial arterial wall. which was loaded with a sinusoidal pressure of 125/85 mmHg. FEA estimates of pressure around the brachial artery cuffs varied by up to 27 mmHg SBP and 17 mmHg DBP with different cuffs. Pressures within the cuffs varied up to 27 mmHg. Pressure transmission from the cuff to the arterial surface achieved a 95% transmission ratio with one rubber-bladdered cuff but varied between 76 and 88% for the others. Non-uniform pressure distribution around the arterial wall was strongly related to cuff fabric elastic modulus. Identical size cuffs with a separate rubber bladder produced peri
DOE Office of Scientific and Technical Information (OSTI.GOV)
Fuse, Takeo; Tada, Yuichiro; Aoyagi, Masaru
1996-03-01
The purpose of this study was to determine the accuracy of high resolution CT (HRCT) in the detection of facial canal dehiscence and semicircular canal fistula, the preoperative evaluation of both of which is clinically very important for ear surgery. We retrospectively reviewed the HRCT findings in 61 patients who underwent mastoidectomy at Yamagata University between 1989 and 1993. The HRCT images were obtained in the axial and semicoronal planes using 1 mm slice thickness and 1 mm intersection gap. In 46 (75%) of the 61 patients, the HRCT image-based assessment of the facial canal dehiscence coincided with the surgicalmore » findings. The data for the facial canal revealed sensitivity of 66% and specificity of 84%. For semicircular canal fistula. in 59 (97%) of the 61 patients, the HRCT image-based assessment and the surgical findings coincided. The image-based assessment in the remaining two patients, who both had massive cholesteatoma, was false-positive. HRCT is useful in the diagnosis of facial canal dehiscence and labyrinthine fistula, but its limitations should also be recognized. 12 refs., 3 figs., 6 tabs.« less
... syndrome of menopause (GSM) increases your risk of: Vaginal infections. Changes in the acid balance of your vagina makes vaginal infections (vaginitis) more likely. Urinary problems. Urinary changes associated ...
Kim, Do Hoon; Jang, Young Hoon; Choi, Young Eun; Lee, Hwa-Ryeong; Kim, Sae Hoon
2016-11-01
Repair tension of a torn rotator cuff can affect healing after repair. However, a measurement of the actual tension during arthroscopic rotator cuff repair is not feasible. The relationship between repair tension and healing of a rotator cuff repair remains unclear. The purpose of this study was to evaluate the effect of repair tension on healing at the repair site. The hypothesis was that repair tension would be a major factor in determining the anatomic outcome of rotator cuff repair. Cohort study; Level of evidence, 2. Arthroscopic rotator cuff repairs (132 patients) for full-thickness rotator cuff tears were analyzed. An intraoperative model was designed for the estimation of repair tension using a tensiometer. Magnetic resonance imaging (MRI) was performed approximately 1 year (mean [±SD], 12.7 ± 3.2 months) postoperatively for the evaluation of healing at the repair site. Multivariable analysis was performed for tear size, amount of retraction, and fatty degeneration (FD) of rotator cuff muscles. The mean repair tension measured during the arthroscopic procedure was 28.5 ± 23.1 N. There was a statistically significant correlation between tension and tear size (Pearson correlation coefficient [PCC], 0.529; P < .001), amount of retraction (PCC, 0.619; P < .001), and FD of the supraspinatus (Spearman correlation coefficient [SCC], 0.308; P < .001) and infraspinatus (SCC, 0.332; P < .001). At the final follow-up (12.7 ± 3.2 months), healing failure was observed in 18.2% (24/132), and repair tension also showed a significant inverse correlation with healing at the repair site (SCC, 0.195; P = .025). However, when sex, age, tear size, amount of retraction, tendon quality, and FD of rotator cuff muscles were included for multivariable logistic regression analysis, only FD of the infraspinatus showed an association with the anatomic outcome of repair (Exp(B) = 0.596; P = .010). Our intraoperative model for the estimation of rotator cuff repair tension showed an
Tang, Xin; Huang, Fuguo; Chen, Gang; Li, Qi; Fu, Weili; Li, Jian
2018-01-01
To investigate effectiveness of rotator cuff repair with manipulation release and arthroscopic debridement for rotator cuff tear with shoulder stiffness. A retrospectively study was performed on the data of 15 patients with rotator cuff tear combined with shoulder stiffness (stiff group) and 24 patients without stiffness (non-stiff group) between January 2014 and December 2015. The patients in the stiff group underwent arthroscopic rotator cuff repair with manipulation release and arthroscopic debridement while the patients in the non-stiff group only received arthroscopic rotator cuff repair. The patients in the stiff group were older than the patients in the non-stiff group, showing significant difference ( P <0.05). There was no significant difference in gender, type of rotator cuff tear, side of rotator cuff tear, and combined with diabetes between 2 groups ( P >0.05). The visual analogue scale (VAS) score, University of California Los Angeles (UCLA) score, American Shoulder and Elbow Surgeons (ASES) score, and range of motion (ROM) were used to evaluate the effectiveness after operation. All incisions healed by first intention without any complication after operation. The patients were followed up 13-31 months in the stiff group (mean, 19.2 months) and 13-23 months in the non-stiff group (mean, 20.3 months). There was no significant difference in follow- up time between 2 groups ( t =-0.573, P =0.570). The VAS score in the stiff group was higher than that in the non-stiff group before operation ( t =-2.166, P =0.037); there was no significant difference between 2 groups at 3, 6, 12 months and last follow-up ( P >0.05). The forward flexion and external rotation were significantly lower in the stiff group than those in the non-stiff group before operation and at 3 months after operation ( P <0.05); there was no significant difference between 2 groups at 6, 12 months and last follow-up ( P >0.05). At last follow-up, the internal rotation was beyond L 3 level in 2
Topical negative pressure for the treatment of neonatal post-sternotomy wound dehiscence.
Hardwicke, J; Richards, H; Jagadeesan, J; Jones, T; Lester, R
2012-01-01
The use of topical negative pressure (TNP) dressings for sternal wound dehiscence or mediastinitis in the neonatal population is rare. The majority of case reports have focused on wound healing as an endpoint and have not discussed the physiological advantage that TNP dressings may impart with regard to sternal stabilisation, improved respiratory function and early weaning from mechanical ventilation. We present a case of the use of TNP in neonatal post-sternotomy wound dehiscence and mediastinitis, from a UK perspective, with an emphasis on wound healing and physiological optimisation. As well as an improvement in sternal wound healing due to the local effects of the TNP system, serial arterial blood gas analysis revealed a significant improvement in systemic physiological parameters, including a reduction in pCO(2) in the period (days 20-31) after application of TNP (p<0.0001) compared to the period before where simple occlusive dressings were applied. Hydrogen ion concentration also significantly reduced in this period (p=0.0058). The use of the TNP system in association with systemic antibiotics successfully treated the mediastinitis. A sealed, controlled wound environment also allowed ease of nursing and an expedited return to care by the parents. We would recommend the consideration of TNP dressings in similar cases of neonatal and paediatric sternal wound dehiscence. Not only do we observe the local effects of improved wound healing, the systemic effects of improved lung function are also valuable in the early management of such complex cases.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Syh, J; Syh, J; Patel, B
2015-06-15
Purpose: The multichannel cylindrical applicator has a distinctive modification of the traditional single channel cylindrical applicator. The novel multichannel applicator has additional peripheral channels that provide more flexibility both in treatment planning process and outcomes. To protect by reducing doses to adjacent organ at risk (OAR) while maintaining target coverage with inverse plan optimization are the goals for such novel Brachytherapy device. Through a series of comparison and analysis of reults in more than forty patients who received HDR Brachytherapy using multichannel vaginal applicator, this procedure has been implemented in our institution. Methods: Multichannel planning was CT image based. Themore » CTV of 5mm vaginal cuff rind with prescribed length was well reconstructed as well as bladder and rectum. At least D95 of CTV coverage is 95% of prescribed dose. Multichannel inverse plan optimization algorithm not only shapes target dose cloud but set dose avoids to OAR’s exclusively. The doses of D2cc, D5cc and D5; volume of V2Gy in OAR’s were selected to compare with single channel results when sole central channel is only possibility. Results: Study demonstrates plan superiorly in OAR’s doe reduction in multi-channel plan. The D2cc of the rectum and bladder were showing a little lower for multichannel vs. single channel. The V2Gy of the rectum was 93.72% vs. 83.79% (p=0.007) for single channel vs. multichannel respectively. Absolute reduced mean dose of D5 by multichannel was 17 cGy (s.d.=6.4) and 44 cGy (s.d.=15.2) in bladder and rectum respectively. Conclusion: The optimization solution in multichannel was to maintain D95 CTV coverage while reducing the dose to OAR’s. Dosimetric advantage in sparing critical organs by using a multichannel applicator in HDR Brachytherapy treatment of the vaginal cuff is so promising and has been implemented clinically.« less
Comparison of outcomes after single or DOUBLE-CUFF artificial urinary sphincter insertion.
O'Connor, R Corey; Gerber, Glenn S; Avila, Desiderio; Chen, Andrew A; Bales, Gregory T
2003-10-01
To assess the effectiveness and complications associated with single and double-cuff artificial urinary sphincter (AUS) implantation for postprostatectomy stress urinary incontinence. A retrospective study of 56 men with postprostatectomy stress urinary incontinence who underwent either single (28 patients) or double (28 patients) cuff AUS placement was performed. Patients in each cohort were matched on the basis of preoperative pad use, risk factors for complications, and age. Patient selection was blinded relative to outcome. Continence, quality of life, and complications were assessed using the Incontinence Impact Questionnaire Short Form (IIQ-7), postoperative pad use, and chart review. The mean age was 67 years for each group. Daily pad use decreased from 7.7 to 1.1 in patients treated with a single-cuff AUS and from 7.8 to 0.7 in patients with a double-cuff AUS (P = 0.25). Complete continence (0 pads daily) was reported in 3 (11%) of 28 men with single-cuff and 12 (43%) of 28 men with double-cuff sphincters (P = 0.008). The IIQ-7 scores improved from 14.8 to 3.1 after single-cuff placement and from 16.3 to 2.5 after double-cuff placement (P = 0.03). With an average follow-up of 41.3 and 21.2 months for the single and double-cuff cohorts, respectively, five complications were reported in the single-cuff recipients and four in the double-cuff patients. A significantly greater rate of complete continence and improvement in the IIQ-7 were seen in men with double-cuff AUS compared with single-cuff devices. Additional study is needed to confirm the relative advantages of double-cuff insertion.
Rotator Cuff Repair in Adolescent Athletes.
Azzam, Michael G; Dugas, Jeffrey R; Andrews, James R; Goldstein, Samuel R; Emblom, Benton A; Cain, E Lyle
2018-04-01
Rotator cuff tears are rare injuries in adolescents but cause significant morbidity if unrecognized. Previous literature on rotator cuff repairs in adolescents is limited to small case series, with few data to guide treatment. Adolescent patients would have excellent functional outcome scores and return to the same level of sports participation after rotator cuff repair but would have some difficulty with returning to overhead sports. Case series; Level of evidence 4. A retrospective search of the practice's billing records identified all patients participating in at least 1 sport who underwent rotator cuff repair between 2006 and 2014 with an age <18 years at the time of surgery and a minimum follow-up of 2 years. Clinical records were evaluated for demographic information, and telephone follow-up was obtained regarding return to play, performance, other surgery and complications, a numeric pain rating scale (0-10) for current shoulder pain, American Shoulder and Elbow Surgeons (ASES) Shoulder Assessment Form, and the Western Ontario Rotator Cuff Index. Thirty-two consecutive adolescent athletes (28 boys and 4 girls) with a mean age of 16.1 years (range, 13.2-17.9 years) met inclusion criteria. Twenty-nine patients (91%) had a traumatic event, and 27 of these patients (93%) had no symptoms before the trauma. The most common single tendon injury was to the supraspinatus (21 patients, 66%), of which 2 were complete tendon tears, 1 was a bony avulsion of the tendon, and 18 were high-grade partial tears. Fourteen patients (56%) underwent single-row repair of their rotator cuff tear, and 11 (44%) underwent double-row repair. All subscapularis injuries were repaired in open fashion, while all other tears were repaired arthroscopically. Twenty-seven patients (84%) completed the outcome questionnaires at a mean 6.2 years after surgery (range, 2-10 years). The mean ASES score was 93 (range, 65-100; SD = 9); mean Western Ontario Rotator Cuff Index, 89% (range, 60%-100%; SD
21 CFR 868.5750 - Inflatable tracheal tube cuff.
Code of Federal Regulations, 2010 CFR
2010-04-01
... cuff. (a) Identification. An inflatable tracheal tube cuff is a device used to provide an airtight seal between a tracheal tube and a patient's trachea. (b) Classification. Class II (performance standards). ...
Lima-Silva, Joana; Vieira-Baptista, Pedro; Cavaco-Gomes, João; Maia, Tiago; Beires, Jorge
2015-04-01
Emphysematous vaginitis is a rare condition, characterized by the presence of multiple gas-filled cysts in the vaginal and/or exocervical mucosa. Although its etiology is not completely understood, it is self-limited, with a benign clinical course. Vaginal discharge, sometimes bloody, and pruritus are the most common symptoms. Chronic and acute inflammation can be found, and diseases that impair the immune system and pregnancy have been associated with this condition. A 48-year-old postmenopausal woman, with a history of hysterectomy with several comorbidities, presented with a 4-month history of bloody discharge and vulvar pruritus. Examination showed multiple cystic lesions, 1 to 5 mm, occupying the posterior and right lateral vaginal walls. Speculum examination produced crepitus. Vaginal wet mount was normal, except for diminished lactobacilli; results of Trichomonas vaginalis DNA test and vaginal cultures were negative. Lugol's iodine applied to the vagina was taken up by the intact lesions. Biopsy result showed typical features of emphysematous vaginitis. This is an unusual entity, presenting with common gynecological complaints, and both physicians and pathologists should be aware to prevent misdiagnosis and overtreatment.
Evaluation of cartilage degeneration in a rat model of rotator cuff tear arthropathy
Kramer, Erik J.; Bodendorfer, Blake M.; Laron, Dominique; Wong, Jason; Kim, Hubert T.; Liu, Xuhui; Feeley, Brian T.
2013-01-01
Introduction Rotator cuff tears are the most common injury seen by shoulder surgeons. Many late stage rotator cuff tear patients develop glenohumeral osteoarthritis as a result of torn cuff tendons, termed cuff tear arthropathy. However, the mechanisms of cuff tear arthropathy have not been fully established. It has been hypothesized that a combination of synovial and mechanical factors contribute equally to the development of cuff tear arthropathy. The goal of this study was to assess the utility of this model in investigating cuff-tear arthropathy. Methods We utilized a rat model which accurately reflects rotator cuff muscle degradation after massive rotator cuff tears through either infraspinatus and supraspinatus tenotomy or suprascapular nerve transection. Using a Modified-Mankin Scoring System (MMS), we found significant glenohumeral cartilage damage following both rotator cuff tenotomy and suprascapular nerve transection after only 12 weeks. Results Cartilage degeneration was similar between groups, and was present on both the humeral head and the glenoid. Denervation of the supraspinatus and infraspinatus muscles without opening the joint capsule caused cartilage degeneration similar to that found in the tendon transection group. Conclusions These results suggest that altered mechanical loading after rotator cuff tears is the primary factor in cartilage degeneration after rotator cuff tears. Clinically, understanding the process of cartilage degeneration after rotator cuff injury will help guide treatment decisions in the setting of rotator cuff tears. Level of evidence Basic Science Study, Animal Model PMID:23664745
Rotator cuff repair using cell sheets derived from human rotator cuff in a rat model.
Harada, Yoshifumi; Mifune, Yutaka; Inui, Atsuyuki; Sakata, Ryosuke; Muto, Tomoyuki; Takase, Fumiaki; Ueda, Yasuhiro; Kataoka, Takeshi; Kokubu, Takeshi; Kuroda, Ryosuke; Kurosaka, Masahiro
2017-02-01
To achieve biological regeneration of tendon-bone junctions, cell sheets of human rotator-cuff derived cells were used in a rat rotator cuff injury model. Human rotator-cuff derived cells were isolated, and cell sheets were made using temperature-responsive culture plates. Infraspinatus tendons in immunodeficient rats were resected bilaterally at the enthesis. In right shoulders, infraspinatus tendons were repaired by the transosseous method and covered with the cell sheet (sheet group), whereas the left infraspinatus tendons were repaired in the same way without the cell sheet (control group). Histological examinations (safranin-O and fast green staining, isolectin B4, type II collagen, and human-specific CD31) and mRNA expression (vascular endothelial growth factor; VEGF, type II collagen; Col2, and tenomodulin; TeM) were analyzed 4 weeks after surgery. Biomechanical tests were performed at 8 weeks. In the sheet group, proteoglycan at the enthesis with more type II collagen and isolectin B4 positive cells were seen compared with in the control group. Human specific CD31-positive cells were detected only in the sheet group. VEGF and Col2 gene expressions were higher and TeM gene expression was lower in the sheet group than in the control group. In mechanical testing, the sheet group showed a significantly higher ultimate failure load than the control group at 8 weeks. Our results indicated that the rotator-cuff derived cell sheet could promote cartilage regeneration and angiogenesis at the enthesis, with superior mechanical strength compared with the control. Treatment for rotator cuff injury using cell sheets could be a promising strategy for enthesis of tendon tissue engineering. © 2016 Orthopaedic Research Society. Published by Wiley Periodicals, Inc. J Orthop Res 35:289-296, 2017. © 2016 Orthopaedic Research Society. Published by Wiley Periodicals, Inc.
Asymptomatic rotator cuff tears: Patient demographics and baseline shoulder function
Keener, Jay D.; Steger-May, Karen; Stobbs, Georgia; Yamaguchi, Ken
2010-01-01
Background The purpose of this study is to characterize the demographic features and physical function of subjects with asymptomatic rotator cuff tears and to compare their shoulder function to controls with an intact rotator cuff. Materials and Methods 196 subjects with an asymptomatic rotator cuff tear and 54 subjects with an intact rotator cuff presenting with a painful rotator cuff tear in the contralateral shoulder were enrolled. Various demographic features, shoulder function (ASES score and SST score), range of motion and strength were compared. Results The demographic features of the study and control groups were similar. Hand dominance was associated with the presence of shoulder pain (p < .05). Subjects with an intact rotator cuff had greater but clinically insignificant ASES (p < .05) and SST scores (p < .05) than those with an asymptomatic tear. No differences in functional scores, range of motion or strength were seen between partial (n=61) and full-thickness tears (n=135). Of the full-thickness tears, 36 (27%) were classified as small, 85 (63%) as medium and 14 (10%) as large tears. No differences were seen in functional scores between full-thickness tears of various sizes. Conclusions When asymptomatic, a rotator cuff tear is associated with a clinically insignificant loss of shoulder function compared to those with an intact rotator cuff. Therefore, a clinically detectable decline in shoulder function may indicate an “at-risk” asymptomatic tear. The presence of pain is important in cuff deficient shoulders for creating a measurable loss of shoulder function. Hand dominance appears to be an important risk factor for pain. PMID:21030274
Altitude-Related Change in Endotracheal Tube Cuff Pressures in Helicopter EMS.
Weisberg, Stacy N; McCall, Jonathan C; Tennyson, Joseph
2017-06-01
Over-inflation of endotracheal tube (ETT) cuffs has the potential to lead to scarring and stenosis of the trachea.1, 2,3, 4 The air inside an ETT cuff is subject to expansion as atmospheric pressure decreases, as happens with an increase in altitude. Emergency medical services helicopters are not pressurized, thereby providing a good environment for studying the effects of altitude changes ETT cuff pressures. This study aims to explore the relationship between altitude and ETT cuff pressures in a helicopter air-medical transport program. ETT cuffs were initially inflated in a nonstandardized manner and then adjusted to a pressure of 25 cmH 2 O. The pressure was again measured when the helicopter reached maximum altitude. A final pressure was recorded when the helicopter landed at the receiving facility. We enrolled 60 subjects in the study. The mean for initial tube cuff pressures was 70 cmH 2 O. Maximum altitude for the program ranged from 1,000-3,000 feet above sea level, with a change in altitude from 800-2,480 feet. Mean cuff pressure at altitude was 36.52 ± 8.56 cmH 2 O. Despite the significant change in cuff pressure at maximum altitude, there was no relationship found between the maximum altitude and the cuff pressures measured. Our study failed to demonstrate the expected linear relationship between ETT cuff pressures and the maximum altitude achieved during typical air-medical transportation in our system. At altitudes less than 3,000 feet above sea level, the effect of altitude change on ETT pressure is minimal and does not require a change in practice to saline-filled cuffs.
21 CFR 870.1120 - Blood pressure cuff.
Code of Federal Regulations, 2010 CFR
2010-04-01
... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Blood pressure cuff. 870.1120 Section 870.1120 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES CARDIOVASCULAR DEVICES Cardiovascular Diagnostic Devices § 870.1120 Blood pressure cuff...
Biomaterials based strategies for rotator cuff repair.
Zhao, Song; Su, Wei; Shah, Vishva; Hobson, Divia; Yildirimer, Lara; Yeung, Kelvin W K; Zhao, Jinzhong; Cui, Wenguo; Zhao, Xin
2017-09-01
Tearing of the rotator cuff commonly occurs as among one of the most frequently experienced tendon disorders. While treatment typically involves surgical repair, failure rates to achieve or sustain healing range from 20 to 90%. The insufficient capacity to recover damaged tendon to heal to the bone, especially at the enthesis, is primarily responsible for the failure rates reported. Various types of biomaterials with special structures have been developed to improve tendon-bone healing and tendon regeneration, and have received considerable attention for replacement, reconstruction, or reinforcement of tendon defects. In this review, we first give a brief introduction of the anatomy of the rotator cuff and then discuss various design strategies to augment rotator cuff repair. Furthermore, we highlight current biomaterials used for repair and their clinical applications as well as the limitations in the literature. We conclude this article with challenges and future directions in designing more advanced biomaterials for augmentation of rotator cuff repair. Copyright © 2017 Elsevier B.V. All rights reserved.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Jiang, H; Lee, Y; Pokhrel, D
2015-06-15
Purpose: As an alternative to cylindrical applicators, air inflated balloon applicators have been introduced into HDR vaginal cuff brachytherapy treatment to achieve sufficient dose to vagina mucosa as well as to spare rectum and bladder. In general, TG43 formulae based treatment planning systems do not take into account tissue inhomogeneity, and air in the balloon applicator can cause higher delivered dose to mucosa than treatment plan reported. We investigated dosimetric effect of air in balloon applicator using the Monte Carlo method. Methods: The thirteen-catheter Capri applicator with a Nucletron Ir-192 seed was modeled for various balloon diameters (2cm to 3.5cm)more » using the MCNP Monte Carlo code. Ir-192 seed was placed in both central and peripheral catheters to replicate real patient situations. Existence of charged particle equilibrium (CPE) with air balloon was evaluated by comparing kerma and dose at various distances (1mm to 70mm) from surface of air-filled applicator. Also mucosa dose by an air-filled applicator was compared with by a water-filled applicator to evaluate dosimetry accuracy of planning system without tissue inhomogeneity correction. Results: Beyond 1mm from air/tissue interface, the difference between kerma and dose was within 2%. CPE (or transient CPE) condition was deemed existent, and in this region no electron transport was necessary in Monte Carlo simulations. At 1mm or less, the deviation of dose from kerma became more apparent. Increase of dose to mucosa depended on diameter of air balloon. The increment of dose to mucosa was 2.5% and 4.3% on average for 2cm and 3.5cm applicators, respectively. Conclusion: After introduction of air balloon applicator, CPE fails only at the proximity of air/tissue interface. Although dose to mucosa is increased, there is no significant dosimetric difference (<5%) between air and water filled applicators. Tissue inhomogeneity correction is not necessary for air-filled applicators.« less
... They include tendinitis, bursitis, and injuries such as tears. Rotator cuff tendons can become inflamed from frequent ... to wear down, which can lead to a tear. Some tears are not painful, but others can ...
... techniques are used to repair a rotator cuff tear: During open repair, a surgical incision is made ... repair is done for large or more complex tears. During arthroscopy, the arthroscope is inserted through small ...
The Societal and Economic Value of Rotator Cuff Repair
Mather, Richard C.; Koenig, Lane; Acevedo, Daniel; Dall, Timothy M.; Gallo, Paul; Romeo, Anthony; Tongue, John; Williams, Gerald
2013-01-01
Background: Although rotator cuff disease is a common musculoskeletal problem in the United States, the impact of this condition on earnings, missed workdays, and disability payments is largely unknown. This study examines the value of surgical treatment for full-thickness rotator cuff tears from a societal perspective. Methods: A Markov decision model was constructed to estimate lifetime direct and indirect costs associated with surgical and continued nonoperative treatment for symptomatic full-thickness rotator cuff tears. All patients were assumed to have been unresponsive to one six-week trial of nonoperative treatment prior to entering the model. Model assumptions were obtained from the literature and data analysis. We obtained estimates of indirect costs using national survey data and patient-reported outcomes. Four indirect costs were modeled: probability of employment, household income, missed workdays, and disability payments. Direct cost estimates were based on average Medicare reimbursements with adjustments to an all-payer population. Effectiveness was expressed in quality-adjusted life years (QALYs). Results: The age-weighted mean total societal savings from rotator cuff repair compared with nonoperative treatment was $13,771 over a patient’s lifetime. Savings ranged from $77,662 for patients who are thirty to thirty-nine years old to a net cost to society of $11,997 for those who are seventy to seventy-nine years old. In addition, surgical treatment results in an average improvement of 0.62 QALY. Societal savings were highly sensitive to age, with savings being positive at the age of sixty-one years and younger. The estimated lifetime societal savings of the approximately 250,000 rotator cuff repairs performed in the U.S. each year was $3.44 billion. Conclusions: Rotator cuff repair for full-thickness tears produces net societal cost savings for patients under the age of sixty-one years and greater QALYs for all patients. Rotator cuff repair is cost
NASA Astrophysics Data System (ADS)
Pinto, Nathali Cordeiro; Shoji, Nara; Junior, Mauro Favoretto; Muramatso, Mikiya; Chavantes, Maria Cristina; Stolf, Noedir A. G.
2008-04-01
Introduction: In Brazil, the main cause of death is the coronary heart disease and the surgical treatment applied in such cases is the Myocardial Revascularization (MR). Patients undergoing to MR through saphenous vein bypass development dehiscence in 10% of the cases. Dehiscence of surgical incision through Biomodulation treatment with Low Level Laser Therapy (LLLT) in patients who underwent to MR seems to be an unprecedented new therapy and a less invasive technique, which can benefit patients and Institutions, reducing costs. Methodology: It was analyzed 7 diabetic patients, mean age 51, 8 years old that post MR surgery presented dehiscence of the saphenectomy incision on lower limb with erithema, edema and pain. The wounds area varies from 2,2 until 34,8 cm and deep from 0,1 until 1,1 cm. It was used only Diode Laser C.W. (655 nm wavelength), Power = 25 mW, Time = 30 s, Fluence = 4 J/cm2 applied punctually around surgical wound's sore, by 2 cm distance. Results: It was observed granulated tissue all around the incision, as well as decreased inflammatory process, reduction fibrin and wound's size, besides analgesic effect since the first application. It was required in superficial wounds only 3 applications, while in the extensive wounds 8-10 applications were necessary. The LLLT has shown a remarkable role as a wound healing facilitated agent, reflecting the reduction of inflammatory process and improving analgesia. Conclusion: LLLT assisted dehiscence post saphenectomy showed a substantial improvement to the patient's quality of life, with a cost-effectiveness treatment that can benefit both patients and Institutions as an effective and less invasive therapy.
Anastomotic dehiscence after gastrectomy for cancer. Personal series.
Lanteri, Raffaele; Rapisarda, Cristian; Santangelo, Marco; Racalbuto, Agostino; Di Cataldo, Antonio; Licata, Antonio
2007-03-01
Nowadays the risk of anastomotic dehiscence after gastrectomy still exists. So the aim of this study was to analyze our experience regarding these anastomoses. In our Surgical Unit, which is located in the Department of Surgical Sciences, Organ Transplantation and Advanced Technologies of the University of Catania, from January 1st 1985 to December 31st 2000, 249 patients underwent surgery for gastric cancer. We observed a statistically significant decrease of leaks in the third period of our study. These data demonstrate a significant decrease of anastomotic leaks with stapler in comparison to manual anastomoses.
Neovascularization prevalence in the supraspinatus of patients with rotator cuff tendinopathy.
Kardouni, Joseph R; Seitz, Amee L; Walsworth, Matthew K; Michener, Lori A
2013-11-01
A high prevalence of neovascularity in lower extremity tendinopathies has been reported. Neovascularity in those with rotator cuff tendinopathy exclusively has not been examined. The objective was to determine the prevalence of neovascularization in patients with rotator cuff tendinopathy compared with asymptomatic controls. Single-blind cross-sectional study. Research laboratory. Participants (n = 40; age = 44.9 years, 23-62 years; 20 females) with rotator cuff tendinopathy (n = 20) but without full-thickness rotator cuff tears, and asymptomatic controls that were age, gender, and hand dominance matched (n = 20) to the patients. The participants laying in supine had their shoulder positioned in internal rotation and extension. Ultrasound images were collected of the supraspinatus tendon and subacromial bursae in the transverse and longitudinal planes using a linear transducer in color Doppler mode. Images were assessed for neovascularization by 2 trained raters who were blinded to group (rotator cuff tendinopathy or asymptomatic group). No statistically significant difference in neovascularization was identified between participants with and without rotator cuff tendinopathy (χ = 0.13, df = 1, P = 0.72). Neovascularization was identified in 6 of 20 patients with rotator cuff tendinopathy (30%) and 5 of 20 asymptomatic control participants (25%). The authors found no differences in neovascularization rate in patients with rotator cuff tendinopathy (30%) and asymptomatic controls (25%). The study indicates that neovascularization is not related to presence of symptomatic tendinopathy in those with rotator cuff tendinopathy. Neovascularization may not be a relevant sonographic finding to aid the clinical assessment of those with rotator cuff tendinopathy.
... are here Home > Types of Cancer > Vaginal Cancer Vaginal Cancer This is Cancer.Net’s Guide to Vaginal Cancer. Use the menu below to choose the ... social workers, and patient advocates. Cancer.Net Guide Vaginal Cancer Introduction Statistics Medical Illustrations Risk Factors and ...
Altitude-Related Change in Endotracheal Tube Cuff Pressures in Helicopter EMS
Weisberg, Stacy N.; McCall, Jonathan C.; Tennyson, Joseph
2017-01-01
Introduction Over-inflation of endotracheal tube (ETT) cuffs has the potential to lead to scarring and stenosis of the trachea.1, 2,3, 4 The air inside an ETT cuff is subject to expansion as atmospheric pressure decreases, as happens with an increase in altitude. Emergency medical services helicopters are not pressurized, thereby providing a good environment for studying the effects of altitude changes ETT cuff pressures. This study aims to explore the relationship between altitude and ETT cuff pressures in a helicopter air-medical transport program. Methods ETT cuffs were initially inflated in a nonstandardized manner and then adjusted to a pressure of 25 cmH2O. The pressure was again measured when the helicopter reached maximum altitude. A final pressure was recorded when the helicopter landed at the receiving facility. Results We enrolled 60 subjects in the study. The mean for initial tube cuff pressures was 70 cmH2O. Maximum altitude for the program ranged from 1,000–3,000 feet above sea level, with a change in altitude from 800–2,480 feet. Mean cuff pressure at altitude was 36.52 ± 8.56 cmH2O. Despite the significant change in cuff pressure at maximum altitude, there was no relationship found between the maximum altitude and the cuff pressures measured. Conclusion Our study failed to demonstrate the expected linear relationship between ETT cuff pressures and the maximum altitude achieved during typical air-medical transportation in our system. At altitudes less than 3,000 feet above sea level, the effect of altitude change on ETT pressure is minimal and does not require a change in practice to saline-filled cuffs. PMID:28611883
Predicting Rotator Cuff Tears Using Data Mining and Bayesian Likelihood Ratios
Lu, Hsueh-Yi; Huang, Chen-Yuan; Su, Chwen-Tzeng; Lin, Chen-Chiang
2014-01-01
Objectives Rotator cuff tear is a common cause of shoulder diseases. Correct diagnosis of rotator cuff tears can save patients from further invasive, costly and painful tests. This study used predictive data mining and Bayesian theory to improve the accuracy of diagnosing rotator cuff tears by clinical examination alone. Methods In this retrospective study, 169 patients who had a preliminary diagnosis of rotator cuff tear on the basis of clinical evaluation followed by confirmatory MRI between 2007 and 2011 were identified. MRI was used as a reference standard to classify rotator cuff tears. The predictor variable was the clinical assessment results, which consisted of 16 attributes. This study employed 2 data mining methods (ANN and the decision tree) and a statistical method (logistic regression) to classify the rotator cuff diagnosis into “tear” and “no tear” groups. Likelihood ratio and Bayesian theory were applied to estimate the probability of rotator cuff tears based on the results of the prediction models. Results Our proposed data mining procedures outperformed the classic statistical method. The correction rate, sensitivity, specificity and area under the ROC curve of predicting a rotator cuff tear were statistical better in the ANN and decision tree models compared to logistic regression. Based on likelihood ratios derived from our prediction models, Fagan's nomogram could be constructed to assess the probability of a patient who has a rotator cuff tear using a pretest probability and a prediction result (tear or no tear). Conclusions Our predictive data mining models, combined with likelihood ratios and Bayesian theory, appear to be good tools to classify rotator cuff tears as well as determine the probability of the presence of the disease to enhance diagnostic decision making for rotator cuff tears. PMID:24733553
National Trends in Surgery for Rotator Cuff Disease in Korea
2017-01-01
The objective of this study was to investigate the national trends in rotator cuff surgery in Korea and analyze hospital type-specific trends. We analyzed a nationwide database acquired from the Korean Health Insurance Review and Assessment Service (HIRA) from 2007 to 2015. International Classification of Diseases, 10th revision (ICD-10) codes, procedure codes, and arthroscopic device code were used to identify patients who underwent surgical treatment for rotator cuff disease. A total of 383,719 cases of rotator cuff surgeries were performed from 2007 to 2015. The mean annual percentage change in the age-adjusted rate of rotator cuff surgery per population of 100,000 persons rapidly increased from 2007 to 2012 (53.3%, P < 0.001), while that between 2012 to 2015 remained steady (2.3%, P = 0.34). The proportion of arthroscopic surgery among all rotator cuff surgeries steadily rose from 89.9% in 2007 to 96.8% in 2015 (P < 0.001). In terms of hospital types, the rate of rotator cuff surgery increased to the greatest degree in hospitals with 30–100 inpatient beds, and isolated acromioplasty procedure accounted for a larger proportion of the rotator cuff surgeries in small hospitals and clinics compared to large hospitals. Overall, our findings indicate that cases of rotator cuff surgery have increased rapidly recently in Korea, of which arthroscopic surgeries account for the greatest proportion. While rotator cuff surgery is a popular procedure that is commonly performed even in small hospitals, there was a difference in the component ratio of the procedure code in accordance with hospital type. PMID:28049250
Vaginal Microbiomes Associated With Aerobic Vaginitis and Bacterial Vaginosis.
Kaambo, Evelyn; Africa, Charlene; Chambuso, Ramadhani; Passmore, Jo-Ann Shelley
2018-01-01
A healthy vaginal microbiota is considered to be significant for maintaining vaginal health and preventing infections. However, certain vaginal bacterial commensal species serve an important first line of defense of the body. Any disruption of this microbial barrier might result in a number of urogenital conditions including aerobic vaginitis (AV) and bacterial vaginosis (BV). The health of the vagina is closely associated with inhabitant microbiota. Furthermore, these microbes maintain a low vaginal pH, prevent the acquisition of pathogens, stimulate or moderate the local innate immune system, and further protect against complications during pregnancies. Therefore, this review will focus on vaginal microbial "health" in the lower reproductive tract of women and on the physiological characteristics that determine the well-being of reproductive health. In addition, we explore the distinct versus shared characteristics of BV and AV, which are commonly associated with increased risk for preterm delivery.
Vaginal Microbiomes Associated With Aerobic Vaginitis and Bacterial Vaginosis
Kaambo, Evelyn; Africa, Charlene; Chambuso, Ramadhani; Passmore, Jo-Ann Shelley
2018-01-01
A healthy vaginal microbiota is considered to be significant for maintaining vaginal health and preventing infections. However, certain vaginal bacterial commensal species serve an important first line of defense of the body. Any disruption of this microbial barrier might result in a number of urogenital conditions including aerobic vaginitis (AV) and bacterial vaginosis (BV). The health of the vagina is closely associated with inhabitant microbiota. Furthermore, these microbes maintain a low vaginal pH, prevent the acquisition of pathogens, stimulate or moderate the local innate immune system, and further protect against complications during pregnancies. Therefore, this review will focus on vaginal microbial “health” in the lower reproductive tract of women and on the physiological characteristics that determine the well-being of reproductive health. In addition, we explore the distinct versus shared characteristics of BV and AV, which are commonly associated with increased risk for preterm delivery. PMID:29632854
Carvalho, Cassiano Diniz; Andreoli, Carlos Vicente; Pochini, Alberto de Castro; Ejnisman, Benno
2016-01-01
To evaluate the clinical and functional behavior of patients undergoing cuff tear arthroplasty at different stages of the disease. Cuff tear arthroplasty hemiarthroplasties were performed in 34 patients with rotator cuff arthropathy and associated comorbidities, classified according to Seebauer. The mean age was 76.3 years, and the sample comprised 23 females (67.6%) and 11 males (32.4%). The mean follow-up period was 21.7 months, and evaluations were performed using the Visual Analog Scale for pain and the Constant scale. There were no statistically significant differences in the mean reduction in the Visual Analog Scale or in the Constant scale increase between the female and male groups. The variation between the pre- and postoperative Visual Analog Scale and Constant scale evaluations was significant. There was also no statistically significant difference between the Seebauer classification groups regarding the mean Visual Analog Scale reduction, or the mean Constant scale increase. Cuff tear arthroplasty shoulder hemiarthroplasty is a good option for rotator cuff arthropathy in patients with comorbidities. Avaliar o comportamento clínico e funcional dos pacientes submetidos à artroplastia do tipo cuff tear arthroplasty para o tratamento da artropatia do manguito rotador em diferentes estágios da afecção. Foram realizadas 34 hemiartroplastias do tipo cuff tear arthroplasty em 34 pacientes com artropatia do manguito rotador e comorbidades associadas, classificadas de acordo com Seebauer. A média de idade foi de 76,3 anos, sendo 23 pacientes do sexo feminino (67,6%) e 11 do sexo masculino (32,4%). O seguimento médio foi de 21,7 meses e a avaliação foi realizada por meio da Escala Visual Analógica da dor e pela escala de Constant. Não houve diferença estatisticamente significante entre os grupos feminino e masculino, tanto nas médias de redução na Escala Visual Analógica quanto nas de aumento na escala de Constant. A variação entre as avalia
Improper tube fixation causing a leaky cuff.
Gupta, Babita; Farooque, Kamran; Jain, Divya; Kapoor, Rakesh
2010-04-01
Leaking endotracheal tube cuffs are common problems in intensive care units. We report a case wherein the inflation tube was damaged by the adhesive plaster used for tube fixation and resulted in leaking endotracheal tube cuff. We also give some suggestions regarding the tube fixation and some remedial measures for damaged inflation system.
Augmentation of Rotator Cuff Repair With Soft Tissue Scaffolds
Thangarajah, Tanujan; Pendegrass, Catherine J.; Shahbazi, Shirin; Lambert, Simon; Alexander, Susan; Blunn, Gordon W.
2015-01-01
Background Tears of the rotator cuff are one of the most common tendon disorders. Treatment often includes surgical repair, but the rate of failure to gain or maintain healing has been reported to be as high as 94%. This has been substantially attributed to the inadequate capacity of tendon to heal once damaged, particularly to bone at the enthesis. A number of strategies have been developed to improve tendon-bone healing, tendon-tendon healing, and tendon regeneration. Scaffolds have received considerable attention for replacement, reconstruction, or reinforcement of tendon defects but may not possess situation-specific or durable mechanical and biological characteristics. Purpose To provide an overview of the biology of tendon-bone healing and the current scaffolds used to augment rotator cuff repairs. Study Design Systematic review; Level of evidence, 4. Methods A preliminary literature search of MEDLINE and Embase databases was performed using the terms rotator cuff scaffolds, rotator cuff augmentation, allografts for rotator cuff repair, xenografts for rotator cuff repair, and synthetic grafts for rotator cuff repair. Results The search identified 438 unique articles. Of these, 214 articles were irrelevant to the topic and were therefore excluded. This left a total of 224 studies that were suitable for analysis. Conclusion A number of novel biomaterials have been developed into biologically and mechanically favorable scaffolds. Few clinical trials have examined their effect on tendon-bone healing in well-designed, long-term follow-up studies with appropriate control groups. While there is still considerable work to be done before scaffolds are introduced into routine clinical practice, there does appear to be a clear indication for their use as an interpositional graft for large and massive retracted rotator cuff tears and when repairing a poor-quality degenerative tendon. PMID:26665095
Does arthroscopic rotator cuff repair improve patients' activity levels?
Baumgarten, Keith M; Chang, Peter S; Dannenbring, Tasha M; Foley, Elaine K
2018-06-04
Rotator cuff repair decreases pain, improves range of motion, and increases strength. Whether these improvements translate to an improvement in a patient's activity level postoperatively remains unknown. The Shoulder Activity Level is a valid and reliable outcomes survey that can be used to measure a patient's shoulder-specific activity level. Currently, there are no studies that examine the effect of rotator cuff repair on shoulder activity level. Preoperative patient-determined outcomes scores collected prospectively on patients undergoing rotator cuff repair were compared with postoperative scores at a minimum of 2 years. These scores included the Shoulder Activity Level, Western Ontario Rotator Cuff Index, American Shoulder and Elbow Surgeons Standardized Shoulder Assessment Form, Single Assessment Numeric Evaluation, and simple shoulder test. Inclusion criteria were patients undergoing arthroscopic rotator cuff repair. Included were 281 shoulders from 273 patients with a mean follow-up of 3.7 years. The postoperative median Western Ontario Rotator Cuff Index (42 vs. 94), American Shoulder and Elbow Surgeons (41 vs. 95), Single Assessment Numeric Evaluation (30 vs. 95), and simple shoulder test (4 vs. 11) scores were statistically significantly improved compared with preoperative scores (P < .0001). The postoperative median Shoulder Activity Level score decreased compared with the preoperative score (12 vs. 11; P < .0001). Patients reported a statistically significant deterioration of their Shoulder Activity Level score after rotator cuff repair compared with their preoperative scores, although disease-specific and joint-specific quality of life scores all had statistically significantly improvement. This study suggests that patients generally have (1) significant improvements in their quality of life and (2) small deteriorations in activity level after arthroscopic rotator cuff repair. Copyright © 2018 Journal of Shoulder and Elbow Surgery Board of
Medial-row failure after arthroscopic double-row rotator cuff repair.
Yamakado, Kotaro; Katsuo, Shin-ichi; Mizuno, Katsunori; Arakawa, Hitoshi; Hayashi, Seigaku
2010-03-01
We report 4 cases of medial-row failure after double-row arthroscopic rotator cuff repair (ARCR) without arthroscopic subacromial decompression (ASAD), in which there was pullout of mattress sutures of the medial row and knots were caught between the cuff and the greater tuberosity. Between October 2006 and January 2008, 49 patients underwent double-row ARCR. During this period, ASAD was not performed with ARCR. Revision arthroscopy was performed in 8 patients because of ongoing symptoms after the index operation. In 4 of 8 patients the medial rotator cuff failed; the tendon appeared to be avulsed at the medial row, and there were exposed knots on the bony surface of the rotator cuff footprint. It appeared that the knots were caught between the cuff and the greater tuberosity. Three retear cuffs were revised with the arthroscopic transtendon technique, and one was revised with a single-row technique after completing the tear. ASAD was performed in all patients. Three of the four patients showed improvement of symptoms and returned to their preinjury occupation. Impingement of pullout knots may be a source of pain after double-row rotator cuff repair. Copyright 2010 Arthroscopy Association of North America. Published by Elsevier Inc. All rights reserved.
Castricini, Roberto; De Benedetto, Massimo; Familiari, Filippo; De Gori, Marco; De Nardo, Pasquale; Orlando, Nicola; Gasparini, Giorgio; Galasso, Olimpio
2016-04-01
Arthroscopic-assisted latissimus dorsi tendon transfer (LDTT) has been recently introduced for treatment of irreparable, posterosuperior massive rotator cuff tears. We sought to evaluate the functional outcomes of this technique and to check for possible outcome predictors. The study reviewed 86 patients (aged 59.8 ± 5.9 years) who underwent an arthroscopic-assisted latissimus dorsi tendon transfer after 36.4 ± 9 months of follow-up. Of these, 14 patients (16.3%) sustained an irreparable massive rotator cuff tear after a failed arthroscopic rotator cuff repair. The Constant and Murley score (CMS) was used to assess patients' functionality preoperatively and at follow-up. As a group, the CMS improved with surgery from 35.5 ± 6.1 to 69.5 ± 12.3 (P < .001). A lower preoperative CMS and a previous failed rotator cuff repair resulted in lower postoperative range of motion (P = .044 and P = .007, respectively) and CMS (P = .042 and P = .018, respectively). A previous rotator cuff repair resulted in lower satisfaction with surgery (P = .009). Gender and age did not affect the clinical outcomes. Our results support the effectiveness of arthroscopic-assisted LDTT in the treatment of patients with an irreparable, posterosuperior massive rotator cuff tears in pain relief, functional recovery, and postoperative satisfaction. Patients with lower preoperative CMS and a history of failed rotator cuff repair have a greater likelihood of having a lower clinical result. However, the favorable values of summary postoperative scores do not exclude these patients as candidates for arthroscopic-assisted LDTT. Copyright © 2016 Journal of Shoulder and Elbow Surgery Board of Trustees. Published by Elsevier Inc. All rights reserved.
Treatment of postmenopausal vaginal atrophy with 10-μg estradiol vaginal tablets.
Panay, Nick; Maamari, Ricardo
2012-03-01
Postmenopausal estrogen deficiency can lead to symptoms of urogenital atrophy. Individuals with urogenital atrophy have symptoms that include vaginal dryness, vaginal and vulval irritation, vaginal soreness, pain and burning during urination (dysuria), increased vaginal discharge, vaginal odour, vaginal infections, recurrent urinary tract infections, pain associated with sexual activity (dyspareunia) and vaginal bleeding associated with sexual activity. Despite the frequency and effects of vaginal atrophy symptoms, they are often under-reported and, consequently, under-treated. Therefore, care of a menopausal woman should include a physical assessment of vaginal atrophy and a dialogue between the physician and the patient that explores existing symptoms and their effect on vulvovaginal health, sexuality and quality-of-life issues. The development of the ultra-low-dose 10-µg estradiol vaginal tablets is in line with the requirements of regulatory agencies and women's health societies regarding the use of the lowest effective hormonal dose. Because of its effectiveness and safety profiles, in addition to its minimal systemic absorption, the 10-µg estradiol vaginal tablet can offer greater reassurance to health-care providers and postmenopausal women with an annual estradiol administration of only 1.14 mg.
Relationship of individual scapular anatomy and degenerative rotator cuff tears.
Moor, Beat K; Wieser, Karl; Slankamenac, Ksenija; Gerber, Christian; Bouaicha, Samy
2014-04-01
The etiology of rotator cuff disease is age related, as documented by prevalence data. Despite conflicting results, growing evidence suggests that distinct scapular morphologies may accelerate the underlying degenerative process. The purpose of the present study was to evaluate the predictive power of 5 commonly used radiologic parameters of scapular morphology to discriminate between patients with intact rotator cuff tendons and those with torn rotator cuff tendons. A pre hoc power analysis was performed to determine the sample size. Two independent readers measured the acromion index, lateral acromion angle, and critical shoulder angle on standardized anteroposterior radiographs. In addition, the acromial morphology according to Bigliani and the acromial slope were determined on true outlet views. Measurements were performed in 51 consecutive patients with documented degenerative rotator cuff tears and in an age- and sex-matched control group of 51 patients with intact rotator cuff tendons. Receiver operating characteristic analyses were performed to determine cutoff values and to assess the sensitivity and specificity of each parameter. Patients with degenerative rotator cuff tears demonstrated significantly higher acromion indices, smaller lateral acromion angles, and larger critical shoulder angles than patients with intact rotator cuffs. However, no difference was found between the acromial morphology according to Bigliani and the acromial slope. With an area under the receiver operating characteristic curve of 0.855 and an odds ratio of 10.8, the critical shoulder angle represented the strongest predictor for the presence of a rotator cuff tear. The acromion index, lateral acromion angle, and critical shoulder angle accurately predict the presence of degenerative rotator cuff tears. Copyright © 2014 Journal of Shoulder and Elbow Surgery Board of Trustees. Published by Mosby, Inc. All rights reserved.
Rotator Cuff Damage: Reexamining the Causes and Treatments.
ERIC Educational Resources Information Center
Nash, Heyward L.
1988-01-01
Sports medicine specialists are beginning to reexamine the causes and treatments of rotator cuff problems, questioning the role of primary impingement in a deficient or torn cuff and trying new surgical procedures as alternatives to the traditional open acromioplasty. (Author/CB)
Regenerative Medicine in Rotator Cuff Injuries
Randelli, Pietro; Ragone, Vincenza; Menon, Alessandra; Cabitza, Paolo; Banfi, Giuseppe
2014-01-01
Rotator cuff injuries are a common source of shoulder pathology and result in an important decrease in quality of patient life. Given the frequency of these injuries, as well as the relatively poor result of surgical intervention, it is not surprising that new and innovative strategies like tissue engineering have become more appealing. Tissue-engineering strategies involve the use of cells and/or bioactive factors to promote tendon regeneration via natural processes. The ability of numerous growth factors to affect tendon healing has been extensively analyzed in vitro and in animal models, showing promising results. Platelet-rich plasma (PRP) is a whole blood fraction which contains several growth factors. Controlled clinical studies using different autologous PRP formulations have provided controversial results. However, favourable structural healing rates have been observed for surgical repair of small and medium rotator cuff tears. Cell-based approaches have also been suggested to enhance tendon healing. Bone marrow is a well known source of mesenchymal stem cells (MSCs). Recently, ex vivo human studies have isolated and cultured distinct populations of MSCs from rotator cuff tendons, long head of the biceps tendon, subacromial bursa, and glenohumeral synovia. Stem cells therapies represent a novel frontier in the management of rotator cuff disease that required further basic and clinical research. PMID:25184132
Glenohumeral instability and rotator cuff tear.
Porcellini, Giuseppe; Caranzano, Francesco; Campi, Fabrizio; Pellegrini, Andrea; Paladini, Paolo
2011-12-01
The prevalence of rotator cuff tears after traumatic dislocation increases with advancing age, a likely consequence of the age-associated deterioration of the structure and mechanical properties of the tendons of the rotator cuff. These are the effective stabilizers of the glenohumeral joint, compressing the humeral head in the 3-dimensional concavity of the glenohumeral joint. It is impossible to establish whether a lesion of the capsular-labrum complex or of the rotator cuff causes or follows a dislocation, regardless of whether it is anterior or posterior. A peripheral nerve or a brachial plexus injury can be associated with tendon lesion and instability, developing the "terrible triad" of the shoulder. Both conservative and surgical management are possible, and surgeons must choose the most appropriate management modality according to the biologic age, functional demands, and type of lesion.
Relationship of ABO Blood Type on Rotator Cuff Tears.
Lee, Doo-Hyung; Lee, Han-Dong; Yoon, Seung-Hyun
2015-11-01
ABO blood groups are associated with various diseases. A relationship between Achilles tendon ruptures and blood type O has been reported, although its pathogenesis was not clear. To the best of our knowledge, there is no published study describing the relationship between blood type and rotator cuff tendon tears. To determine whether patients with rotator cuff tear had a greater prevalence of blood type O than those without rotator cuff tear. A cross-sectional study. Research hospital outpatient evaluation. A total of 316 subjects with shoulder pain were included and divided into "tear" and "no-tear" groups according to ultrasonographic examination. ABO blood group, gender, dominant arm, smoking history, trauma history, and age were compared between the 2 groups and the odds ratios of these factors were evaluated by logistic regression. The tear group (38.6%) had more instances of blood type O than the healthy population (27.2%; P = .002). The adjusted odds ratio for rotator cuff tear for blood type O to non-O was 2.38 (95% confidence interval 1.28-4.42). The odds ratios for rotator cuff tears for smoking, major trauma history, minor trauma history, and age were 2.08, 3.11, 2.29, and 1.06, respectively. Patients with rotator cuff tears were more likely to have blood type O. The odds ratios of factors for rotator cuff tears were high in the following order: major trauma history, blood type O, minor trauma history, and age. Copyright © 2015 American Academy of Physical Medicine and Rehabilitation. Published by Elsevier Inc. All rights reserved.
McNamara, William J; Lam, Patrick H; Murrell, George A C
2016-11-16
Retear and stiffness are not uncommon outcomes of rotator cuff repair. The purpose of this study was to evaluate the relationship between rotator cuff repair healing and shoulder stiffness. A total of 1,533 consecutive shoulders had an arthroscopic rotator cuff repair by a single surgeon. Patients assessed their shoulder stiffness using a Likert scale preoperatively and at 1, 6, 12, and 24 weeks (6 months) postoperatively, and examiners evaluated passive range of motion preoperatively and at 6, 12, and 24 weeks postoperatively. Repair integrity was determined by ultrasound evaluation at 6 months. After rotator cuff repair, there was an overall significant loss of patient-ranked and examiner-assessed shoulder motion at 6 weeks compared with preoperative measurements (p < 0.0001), a partial recovery at 12 weeks, and a full recovery at 24 weeks. Shoulders that were stiff before surgery were more likely to be stiff at 6, 12, and, to a lesser extent, 24 weeks after surgery (r = 0.10 to 0.31; p < 0.0001). A stiffer shoulder at 6 and 12 weeks (but not 24 weeks) postoperatively correlated with better rotator cuff integrity at 6 months postoperatively (r = 0.11 to 0.18; p < 0.001). The retear rate of patients with ≤20° of external rotation at 6 weeks postoperatively was 7%, while the retear rate of patients with >20° of external rotation at 6 weeks was 15% (p < 0.001). In patients who developed stiffness after surgery, a rotator cuff repair was more likely to heal. Therapeutic Level III. See Instructions for Authors for a complete description of levels of evidence. Copyright © 2016 by The Journal of Bone and Joint Surgery, Incorporated.
Cvetkovic, Aleksandar M; Milasinovic, Danko Z; Peulic, Aleksandar S; Mijailovic, Nikola V; Filipovic, Nenad D; Zdravkovic, Nebojsa D
2014-11-01
The main goal of this study was to numerically quantify risk of duodenal stump blowout after Billroth II (BII) gastric resection. Our hypothesis was that the geometry of the reconstructed tract after BII resection is one of the key factors that can lead to duodenal dehiscence. We used computational fluid dynamics (CFD) with finite element (FE) simulations of various models of BII reconstructed gastrointestinal (GI) tract, as well as non-perfused, ex vivo, porcine experimental models. As main geometrical parameters for FE postoperative models we have used duodenal stump length and inclination between gastric remnant and duodenal stump. Virtual gastric resection was performed on each of 3D FE models based on multislice Computer Tomography (CT) DICOM. According to our computer simulation the difference between maximal duodenal stump pressures for models with most and least preferable geometry of reconstructed GI tract is about 30%. We compared the resulting postoperative duodenal pressure from computer simulations with duodenal stump dehiscence pressure from the experiment. Pressure at duodenal stump after BII resection obtained by computer simulation is 4-5 times lower than the dehiscence pressure according to our experiment on isolated bowel segment. Our conclusion is that if the surgery is performed technically correct, geometry variations of the reconstructed GI tract by themselves are not sufficient to cause duodenal stump blowout. Pressure that develops in the duodenal stump after BII resection using omega loop, only in the conjunction with other risk factors can cause duodenal dehiscence. Increased duodenal pressure after BII resection is risk factor. Hence we recommend the routine use of Roux en Y anastomosis as a safer solution in terms of resulting intraluminal pressure. However, if the surgeon decides to perform BII reconstruction, results obtained with this methodology can be valuable. Copyright © 2014 Elsevier Ireland Ltd. All rights reserved.
Yılmaz, Kerim Bora; Akıncı, Melih; Doğan, Lütfi; Karaman, Niyazi; Özaslan, Cihangir; Atalay, Can
2013-01-01
Post-laparotomy wound dehiscence, evantration and evisceration are important complications leading to an increase in both morbidity and mortality. Incisional hernias are frequently observed following abdominal surgeries and their occurrence is related to various local and systemic factors. This study aims to analyze the factors affecting wound healing by investigating the parameters that may cause wound dehiscence, incisional hernia, sinus formation and chronic incisional pain. The records of 265 patients who underwent major abdominal surgery were analyzed. The data on patient characteristics, medication, surgical procedure type, type of suture and surgical instruments used and complications were recorded. The patients were followed up with respect to sinus formation, incisional hernia occurrence and presence of chronic incision pain. Statistical analysis was performed using SPSS 10.00 program. The groups were compared via chi-square tests. Significance was determined as p<0.05. Multi-variate analysis was done by forward logistic regression analysis. 115 (43.4%) patients were female and 150 (56.6%) were male. Ninety-four (35.5%) patients were under 50 years old and 171 (64.5%) were older than 50 years. The median follow-up period was 28 months (0-48). Factors affecting wound dehiscence were found to be; creation of an ostomy (p=0.002), postoperative pulmonary problems (p=0.001) and wound infection (p=0.001). Factors leading to incisional hernia were; incision type (p=0.002), formation of an ostomy (p=0.002), postoperative bowel obstruction (p=0.027), postoperative pulmonary problems (p=0.017) and wound infection (p=0.011). Awareness of the factors causing wound dehiscence and incisional hernia in abdominal surgery, means of intervention to the risk factors and taking relevant measures may prevent complications. Surgical complications that occur in the postoperative period are especially related to wound healing problems.
Oh, Joo Han; Jun, Bong Jae; McGarry, Michelle H; Lee, Thay Q
2011-11-16
It is unknown at which stage of rotator cuff tear the biomechanical environment is altered. The purpose of this study was to determine if a critical rotator cuff tear stage exists that alters glenohumeral joint biomechanics throughout the rotational range of shoulder motion, and to evaluate the biomechanical effect of parascapular muscle-loading. Eight cadaver shoulders were used with a custom testing system. Four progressive rotator cuff tear stages were investigated on the basis of footprint anatomy. Three muscle-loading conditions were examined: rotator cuff only; rotator cuff with deltoid muscle; and rotator cuff, deltoid, pectoralis major, and latissimus dorsi muscles. Testing was performed in the scapular plane with 0°, 30°, and 60° of shoulder abduction. The maximum internal and external rotations were measured with 3.4 Nm of torque. The position of the humeral head apex with respect to the glenoid was calculated with use of a MicroScribe 3DLX digitizing system throughout the rotational range of motion. The abduction capability was determined as the abduction angle achieved with increasing deltoid load. Tear of the entire supraspinatus tendon significantly increased maximum external rotation and significantly decreased abduction capability with higher deltoid loads (p < 0.05). Tear of the entire supraspinatus tendon and half of the infraspinatus tendon significantly shifted the humeral head apex posteriorly at the midrange of rotation and superiorly at maximum internal rotation (p < 0.05). Loading the pectoralis major and latissimus dorsi muscles decreased the amount of humeral head elevation due to deltoid loading. Tear of the entire supraspinatus tendon was the critical stage for increasing rotational range of shoulder motion and for decreased abduction capability. Further tear progression to the infraspinatus muscle was the critical stage for significant changes in humeral head kinematics. The pectoralis major and latissimus dorsi muscles played an
Hansen, Keith A; DeWitt, Jason
2005-12-01
To describe an unusual, premenarchal presentation of an obstructive vaginal anomaly. Case Report. University Medical Center. Premenarchal subject Vaginogram, vaginal septum resection. Vaginal septum resection with resolution of vaginal discharge. This case demonstrates some of the typical features of uterus didelphys bicollis with incomplete obstructing hemivagina, but had a unique presentation with premenarchal, recurrent vaginal discharge. Typically, patients with an obstructing mullerian anomaly present after menarche with pelvic pain and a mass. The vaginogram assists in the preoperative definition of abnormal anatomy which allows the surgeon to develop the most appropriate surgical approach. Resection of this incompletely obstructing vaginal septum resulted in resolution of the recurrent vaginal discharge.
Hysterectomy - vaginal - discharge
Vaginal hysterectomy - discharge; Laparoscopically assisted vaginal hysterectomy - discharge; LAVH - discharge ... you were in the hospital, you had a vaginal hysterectomy. Your surgeon made a cut in your ...
Stricker, T; Navratil, F; Sennhauser, F H
2004-04-01
To evaluate the clinical features and outcome in girls with a vaginal foreign body. Retrospective review of medical records of 35 girls with a vaginal foreign body seen in an outpatient clinic for paediatric and adolescent gynaecology between 1980 and 2000. The ages ranged from 2.6 to 9.2 years. The most common symptom was blood-stained vaginal discharge/vaginal bleeding (49%). Duration of symptoms varied from 1 day to 2 years. Fifty-four percent of the patients recalled insertion of the foreign object, usually by the girl herself. All but three patients (91%) either recalled insertion of the foreign object and/or had vaginal bleeding or blood-stained or foul-smelling vaginal discharge, and/or visualization or palpation of the foreign body in physical examination. Symptoms resolved after removal of the foreign body followed by a single irrigation with Providon-Iod (Betadine). In the majority of patients a carefully obtained history and physical examination suggest the diagnosis of a vaginal foreign object. The leading symptoms are vaginal bleeding and blood-stained or foul smelling vaginal discharge. Removal of the foreign object followed by a single irrigation with Providon-Iod is the definitive treatment and does not require additional measures.
Relationship between Surgically Treated Superior Canal Dehiscence Syndrome and Body Mass Index.
Jan, Taha A; Cheng, Yew Song; Landegger, Lukas D; Lin, Brian M; Srikanth, Priya; Niesten, Marlien E F; Lee, Daniel J
2017-04-01
Objective Examine the association between body mass index (BMI) and superior canal dehiscence (SCD) among patients who have undergone surgical repair for superior canal dehiscence. Study Design Retrospective comparison study. Setting Neurotology tertiary care center. Subjects and Methods Retrospective review of consecutive adult patients evaluated at our institution for SCD syndrome between November 2006 and August 2015. A control group who underwent imaging within the same period for reasons other than SCD was also included. Patient demographics, weight, and height were examined. We performed multiple subgroup analyses to investigate the relationship of BMI, surgery vs no surgery, and correlation between patient BMI and SCD size. Results Of the 268 patients with SCD, 99 underwent surgery; 96 of these patients had complete medical records and were eligible for inclusion. Eighty-eight patients were noted to have arcuate eminence defects, and the mean BMI of this surgical cohort was 28.09 ± 5.26 kg/m 2 . Nonsurgically treated patients with SCD with available data (n = 94) had a mean BMI of 27.97 ± 6.95 kg/m 2 . A control group of 204 patients who underwent computed tomography for non-SCD-related causes was analyzed, of whom 155 had available data with a mean BMI of 27.91 ± 6.38 kg/m 2 . Conclusion We demonstrate that adult patients who undergo surgery for SCD are not obese (mean BMI <30), and size of dehiscence poorly correlates with BMI. Our observations call into question the proposed theory that patient weight is a risk factor for the development of symptomatic SCD involving the arcuate eminence.
Endotracheal cuff pressure changes with change in position in neurosurgical patients.
Athiraman, UmeshKumar; Gupta, Rohit; Singh, Georgene
2015-01-01
Placement of a cuffed endotracheal tube for the administration of general anesthesia is routine. The cuff of the endotracheal tube is inflated with air to achieve an adequate seal to prevent micro-aspiration. Over inflation of the cuff can decrease the mucosal perfusion, leading to pressure necrosis and nerve palsies. Inadequate seal can lead to micro aspiration. So the cuff pressure has to be monitored and kept within the prescribed limits of 20-30 cms of water. To observe the effect of different positions on the endotracheal cuff pressure in patients undergoing neurosurgical procedures. This is an observational study conducted on 70 patients undergoing neurosurgical procedures in various positions. After intubation, the cuff pressure was checked with a cuff pressure manometer, Endotest (Teleflex Medical, Rush) and adjusted to be within the allowable pressure limits as is the routine practice. The cuff pressure was checked again at three time points after achieving the final position with the head on pins, at the end of the procedure and before extubation. Various factors such as the age, position, duration of surgery were studied. There were no major complications like aspiration, stridor or hoarseness of voice post extubation in any of the patients. A significant decline in the cuff pressures were noted from the initial supine position to extubation (P < .001) in the supine group. Also a significant decline in the cuff pressures were found in the prone group from their initial intubated supine position to all the other three corresponding time points namely after final positioning (P < .001), at the end of the procedure (P < .001) and before extubation (P < .001). Cuff pressure has to be checked after achieving the final positioning of the patient and adjusted to the prescribed limits to prevent micro aspiration.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Zhang, Hualin, E-mail: hualin.zhang@northwestern.edu; Donnelly, Eric D.; Strauss, Jonathan B.
Purpose: To evaluate high-dose-rate (HDR) vaginal cuff brachytherapy (VCBT) in the treatment of endometrial cancer in a cylindrical target volume with either a varied or a constant cancer cell distributions using the linear quadratic (LQ) model. Methods: A Monte Carlo (MC) technique was used to calculate the 3D dose distribution of HDR VCBT over a variety of cylinder diameters and treatment lengths. A treatment planning system (TPS) was used to make plans for the various cylinder diameters, treatment lengths, and prescriptions using the clinical protocol. The dwell times obtained from the TPS were fed into MC. The LQ model wasmore » used to evaluate the therapeutic outcome of two brachytherapy regimens prescribed either at 0.5 cm depth (5.5 Gy × 4 fractions) or at the vaginal mucosal surface (8.8 Gy × 4 fractions) for the treatment of endometrial cancer. An experimentally determined endometrial cancer cell distribution, which showed a varied and resembled a half-Gaussian distribution, was used in radiobiology modeling. The equivalent uniform dose (EUD) to cancer cells was calculated for each treatment scenario. The therapeutic ratio (TR) was defined by comparing VCBT with a uniform dose radiotherapy plan in term of normal cell survival at the same level of cancer cell killing. Calculations of clinical impact were run twice assuming two different types of cancer cell density distributions in the cylindrical target volume: (1) a half-Gaussian or (2) a uniform distribution. Results: EUDs were weakly dependent on cylinder size, treatment length, and the prescription depth, but strongly dependent on the cancer cell distribution. TRs were strongly dependent on the cylinder size, treatment length, types of the cancer cell distributions, and the sensitivity of normal tissue. With a half-Gaussian distribution of cancer cells which populated at the vaginal mucosa the most, the EUDs were between 6.9 Gy × 4 and 7.8 Gy × 4, the TRs were in the range from (5.0){sup 4} to
Jahic, Mahira; Mulavdic, Mirsada; Nurkic, Jasmina; Jahic, Elmir; Nurkic, Midhat
2013-12-01
Examine clinical characteristics of aerobic vaginitis and mixed infection for the purpose of better diagnostic accuracy and treatment efficiency. Prospective research has been conducted at Clinic for Gynecology and Obstetrics, Department for Microbiology and Pathology at Polyclinic for laboratory diagnostic and Gynecology and Obstetrics Department at Health Center Sapna. Examination included 100 examinees with the signs of vaginitis. anamnesis, clinical, gynecological and microbiological examination of vaginal smear. The average age of the examinees was 32,62±2,6. Examining vaginal smears of the examinees with signs of vaginitis in 96% (N-96) different microorganisms have been isolated, while in 4% (N-4) findings were normal. AV has been found in 51% (N-51) of the examinees, Candida albicans in 17% (N-17), BV in 15% (N-15), Trichomonas vaginalis in 13% (N-13). In 21% (N-21) AV was diagnosed alone while associated with other agents in 30% (N-30). Most common causes of AV are E. coli (N-55) and E. faecalis (N-52). AV and Candida albicanis have been found in (13/30, 43%), Trichomonas vaginalis in (9/30, 30%) and BV (8/30, 26%). Vaginal secretion is in 70,05% (N-36) yellow coloured, red vagina wall is recorded in 31,13% (N-16) and pruritus in 72,54% (N-37). Increased pH value of vagina found in 94,10% (N-48). The average pH value of vaginal environment was 5,15±0,54 and in associated presence of AV and VVC, TV and BV was 5,29±0,56 which is higher value considering presence of AV alone but that is not statistically significant difference (p>0,05). Amino-odor test was positive in 29,94% (N-15) of associated infections. Lactobacilli are absent, while leukocytes are increased in 100% (N-51) of the examinees with AV. AV is vaginal infection similar to other vaginal infections. It is important to be careful while diagnosing because the treatment of AV differentiates from treatment of other vaginitis.
Value of bacterial culture of vaginal swabs in diagnosis of vaginal infections.
Nenadić, Dane; Pavlović, Miloš D
2015-06-01
Vaginal and cervical swab culture is still very common procedure in our country's everyday practice whereas simple and rapid diagnostic methods have been very rarely used. The aim of this study was to show that the employment of simple and rapid diagnostic tools [vaginal fluid wet mount microscopy (VFWMM), vaginal pH and potassium hydroxide (KOH) test] offers better assessment of vaginal environment than standard microbiologic culture commonly used in Serbia. This prospective study included 505 asymptomatic pregnant women undergoing VFWMM, test with 10% KOH, determination of vaginal pH and standard culture of cervicovaginal swabs. Combining findings from the procedures was used to make diagnoses of bacterial vaginosis (BV) and vaginitis. In addition, the number of polymorphonuclear leukocytes (PMN) was determined in each sample and analyzed along with other findings. Infections with Candida albicans and Trichomonas vaginalis were confirmed or excluded by microscopic examination. In 36 (6%) patients cervicovaginal swab cultures retrieved several aerobes and facultative anaerobes, whereas in 52 (11%) women Candida albicans was isolated. Based on VFWMM findings and clinical criteria 96 (19%) women had BV, 19 (4%) vaginitis, and 72 (14%) candidiasis. Of 115 women with BV and vaginitis, pH 4.5 was found in 5, and of 390 with normal findings 83 (21%) had vaginal pH 4.5. Elevated numbers of PMN were found in 154 (30%) women--in 83 (54%) of them VFWMM was normal. Specificity and sensitivity of KOH test and vaginal pH determination in defining pathological vaginal flora were 95% and 81%, and 79% and 91%, respectively. Cervicovaginal swab culture is expensive but almost non-informative test in clinical practice. The use of simpler and rapid methods as vaginal fluid wet mount microscopy, KOH test and vaginal pH offers better results in diagnosis, and probably in the treatment and prevention of sequels of vaginal infections.
Saline soaked pledgets prevent carbon dioxide laser-induced endotracheal tube cuff ignition.
Sosis, M B
1995-08-01
To determine whether saline soaked pledgets would protect the cuffs of polyvinylchloride (PVC) endotracheal tubes from carbon dioxide (CO2) laser-induced combustion. 12 PVC endotracheal tubes were studied. The cuffed end of each was placed in a graduated cylinder and flushed with 5 L/min of oxygen for 5 minutes. The endotracheal tube's cuff was then inflated with air and the system pressure set to 20 cm H2O. Research laboratory of a university hospital. Six of the endotracheal tube cuffs were protected with 1 inch by 3 inch saline soaked pledgets and six were left unprotected. A CO2 laser set to 40 watts was then fired at the cuffs. All six unprotected cuffs were ignited in less than 1 second. No significant combustion occurred at the six pledget protected endotracheal tube cuffs after 1 minute of laser fire. Under the conditions of this experiment, saline soaked pledgets protected PVC endotracheal tube cuffs from the CO2 laser.
Characteristics and Clinical Outcomes in Overhead Sports Athletes after Rotator Cuff Repair
Inui, Hiroaki; Ninomiya, Hiroki; Tanaka, Hiroshi; Nobuhara, Katsuya
2017-01-01
Rotator cuff tears in young overhead sports athletes are rare. The pathomechanism causing rotator cuff tears in young overhead athletes is different from that in aged patients. The purpose of this study was to investigate rotator cuff tear characteristics in young overhead sports athletes to reveal the pathomechanism causing these injuries. This study included 25 overhead sports athletes less than 30 years old with atraumatic rotator cuff tears necessitating repair. Rotator cuff tear characteristics were evaluated intraoperatively, including rotator cuff tear shape and injured rotator cuff tendon. Clinical outcome measures were assessed before surgery and at the final follow-up. In this study, 22 patients reported minimal to no shoulder pain and returned to sports without significant complaints at last follow-up. The isolated infraspinatus tendon was most often injured; the incidence rate of the tear at this site was 32% (8 cases). In the deceleration phase of overhead motion, the eccentric contraction force of the ISP (infraspinatus) tendon peaks and the increased load leads to injury at the ISP tendon. The pathomechanism of rotator cuff injuries in young overhead athletes might be not only internal or subacromial impingement, but also these mechanisms. PMID:28702502
Miraftabi, Arezoo; Nilforushan, Naveed
2016-01-01
To report a complication pertaining to subconjunctival bevacizumab injection as an adjunct to Ahmed Glaucoma Valve (AGV) implantation. A 54-year-old woman with history of complicated cataract surgery was referred for advanced intractable glaucoma. AGV implantation with adjunctive subconjunctival bevacizumab (1.25 mg) was performed with satisfactory results during the first postoperative week. However, 10 days after surgery, she developed wound dehiscence and tube exposure. The second case was a 33-year-old man with history of congenital glaucoma and uncontrolled IOP who developed AGV exposure and wound dehiscence after surgery. In both cases, for prevention of endophthalmitis and corneal damage by the unstable tube, the shunt was removed and the conjunctiva was re-sutured. The potential adverse effect of subconjunctival bevacizumab injection on wound healing should be considered in AGV surgery.
Effect of contacts configuration and location on selective stimulation of cuff electrode.
Taghipour-Farshi, Hamed; Frounchi, Javad; Ahmadiasl, Nasser; Shahabi, Parviz; Salekzamani, Yaghoub
2015-01-01
Cuff electrodes have been widely used chronically in different clinical applications. Advancements have been made in selective stimulation by using multi-contact cuff electrodes. Steering anodic current is a strategy to increase selectivity by reshaping and localizing electric fields. There are two configurations for contacts to be implemented in cuff, monopolar and tripolar. A cuff electrode with tripolar configuration can restrict the activation to a more localized region within a nerve trunk compared to a cuff with monopolar configuration and improve the selectivity. Anode contacts in tripolar configuration can be made in two structures, "ring" and "dot". In this study, the stimulation capabilities of these two structures were evaluated. The recruitment properties and the selectivity of stimulation were examined by measuring the electric potential produced by stimulation currents. The results of the present study indicated that using dot configuration, the current needed to stimulate fascicles in tripolar topologies would be reduced by 10%. It was also shown that stimulation threshold was increased by moving anode contacts inward the cuff. On the other hand, stimulation threshold was decreased by moving the anode contacts outward the cuff which would decrease selectivity, too. We conclude that dot configuration is a better choice for stimulation. Also, a cuff inward placement of 10% relative to the cuff length was near optimal.
Extracorporeal shock wave treatment for chronic rotator cuff tendonitis (shoulder pain).
Ho, C
2007-01-01
(1) Electrohydraulic, electromagnetic, or piezoelectric devices are used to translate energy into acoustic waves during extracorporeal shock wave treatment (ESWT) for chronic rotator cuff tendonitis (shoulder pain). The acoustic waves may help to accelerate the healing process of chronic rotator cuff tendonitis via an unknown mechanism. (2) ESWT, which is performed as an outpatient procedure, is intended to alleviate the pain due to chronic rotator cuff tendonitis. (3) Limited evidence from a German study indicates that the cost of ESWT for rotator cuff tendonitis is one-fifth to one-seventh the cost of surgical treatment, with longer recovery time and time off work in the surgical treatment group accounting for about two-thirds of the overall cost. (4) The evidence reviewed for this bulletin supports the use of high-energy ESWT for chronic calcific rotator cuff tendonitis, but not for non-calcific rotator cuff tendonitis. High-quality RCTs with larger sample sizes are needed to provide stronger evidence.
Zehnder, Ashley M; Hawkins, Michelle G; Pascoe, Peter J; Kass, Philip H
2009-09-01
To compare Doppler and oscillometric methods of indirect arterial blood pressure (IBP) with direct arterial measurements in anesthetized and awake red-tailed hawks. Prospective, randomized, blinded study. Six, sex unknown, adult red-tailed hawks. Birds were anesthetized and IBP measurements were obtained by oscillometry (IBP-O) and Doppler (IBP-D) on the pectoral and pelvic limbs using three cuffs of different width based on limb circumference: cuff 1 (20-30% of circumference), cuff 2 (30-40%), and cuff 3 (40-50%). Direct arterial pressure measurements were obtained from the contralateral superficial ulnar artery. Indirect blood pressure measurements were compared to direct systolic arterial pressure (SAP) and mean arterial pressure (MAP) during normotension and induced states of hypotension and hypertension. Measurements were also obtained in awake, restrained birds. Three-way anova, linear regression and Bland-Altman analyses were used to evaluate the IBP-D data. Results are reported as mean bias (95% confidence intervals). The IBP-O monitor reported errors during 54% of the measurements. Indirect blood pressure Doppler measurements were most accurate with cuff 3 and were comparable to MAP with a bias of 2 (-9, 13 mmHg). However, this cuff consistently underestimated SAP with a bias of 33 (19, 48 mmHg). Variability in the readings within and among birds was high. There was no significant difference between sites of cuff placement. Awake birds had SAP, MAP and diastolic arterial pressure that were 56, 43, and 38 mmHg higher than anesthetized birds. Indirect blood pressure (oscillometric) measurements were unreliable in red-tailed hawks. Indirect blood pressure (Doppler) measurements were closer to MAP measurements than SAP measurements. There was slightly better agreement with the use of cuff 3 on either the pectoral or pelvic limbs. Awake, restrained birds have significantly higher arterial pressures than those under sevoflurane anesthesia.
Establishing Maximal Medical Improvement After Arthroscopic Rotator Cuff Repair.
Zuke, William A; Leroux, Timothy S; Gregory, Bonnie P; Black, Austin; Forsythe, Brian; Romeo, Anthony A; Verma, Nikhil N
2018-03-01
As health care transitions from a pay-for-service to a pay-for-performance infrastructure, the value of orthopaedic care must be defined accurately. Significant efforts have been made in defining quality and cost in arthroplasty; however, there remains a lag in ambulatory orthopaedic care. Two-year follow-up has been a general requirement for reporting outcomes after rotator cuff repair. However, this time requirement has not been established scientifically and is of increasing importance in the era of value-based health care. Given that arthroscopic rotator cuff repair is a common ambulatory orthopaedic procedure, the purpose of this study was to establish a time frame for maximal medical improvement (the state when improvement has stabilized) after arthroscopic rotator cuff repair. Systematic review. A systematic review of the literature was conducted, identifying studies reporting sequential patient-reported outcomes up to a minimum of 2 years after arthroscopic rotator cuff repair. The primary clinical outcome was patient-reported outcomes at 3-month, 6-month, 1-year, and 2-year follow-up. Secondary clinical outcomes included range of motion, strength, retears, and complications. Clinically significant improvement was determined between various time intervals by use of the minimal clinically important difference. The review included 19 studies including 1370 patients who underwent rotator cuff repair. Clinically significant improvement in patient-reported outcomes was seen up to 1 year after rotator cuff repair, but no clinical significance was noted from 1 year to 2 years. The majority of improvement in strength and range of motion was seen up to 6 months, but no clinically meaningful improvement was seen thereafter. All reported complications and the majority of retears occurred within 6 months after rotator cuff repair. After rotator cuff repair, a clinically significant improvement in patient-reported outcomes, range of motion, and strength was seen up to 1
Boorman, Richard S; More, Kristie D; Hollinshead, Robert M; Wiley, James P; Mohtadi, Nicholas G; Lo, Ian K Y; Brett, Kelly R
2018-03-01
The purpose of this study was to examine 5-year outcomes in a prospective cohort of patients previously enrolled in a nonoperative rotator cuff tear treatment program. Patients with chronic (>3 months), full-thickness rotator cuff tears (demonstrated on imaging) who were referred to 1 of 2 senior shoulder surgeons were enrolled in the study between October 2008 and September 2010. They participated in a comprehensive, nonoperative, home-based treatment program. After 3 months, the outcome in these patients was defined as "successful" or "failed." Patients in the successful group were essentially asymptomatic and did not require surgery. Patients in the failed group were symptomatic and consented to undergo surgical repair. All patients were followed up at 1 year, 2 years, and 5 or more years. At 5 or more years, all patients were contacted for follow-up; the response rate was 84%. Approximately 75% of patients remained successfully treated with nonoperative treatment at 5 years and reported a mean rotator cuff quality-of-life index score of 83 of 100 (SD, 16). Furthermore, between 2 and 5 years, only 3 patients who had previously been defined as having a successful outcome became more symptomatic and underwent surgical rotator cuff repair. Those in whom nonoperative treatment had failed and who underwent surgical repair had a mean rotator cuff quality-of-life index score of 89 (SD, 11) at 5-year follow-up. The operative and nonoperative groups at 5-year follow-up were not significantly different (P = .11). Nonoperative treatment is an effective and lasting option for many patients with a chronic, full-thickness rotator cuff tear. While some clinicians may argue that nonoperative treatment delays inevitable surgical repair, our study shows that patients can do very well over time. Copyright © 2017 Journal of Shoulder and Elbow Surgery Board of Trustees. Published by Elsevier Inc. All rights reserved.
Yeast infection - vagina; Vaginal candidiasis; Monilial vaginitis ... Most women have a vaginal yeast infection at some time. Candida albicans is a common type of fungus. It is often found in small amounts in the ...
Influence of rotator cuff tears on glenohumeral stability during abduction tasks.
Hölscher, Thomas; Weber, Tim; Lazarev, Igor; Englert, Carsten; Dendorfer, Sebastian
2016-09-01
One of the main goals in reconstructing rotator cuff tears is the restoration of glenohumeral joint stability, which is subsequently of utmost importance in order to prevent degenerative damage such as superior labral anterior posterior (SLAP) lesion, arthrosis, and malfunction. The goal of the current study was to facilitate musculoskeletal models in order to estimate glenohumeral instability introduced by muscle weakness due to cuff lesions. Inverse dynamics simulations were used to compute joint reaction forces for several static abduction tasks with different muscle weakness. Results were compared with the existing literature in order to ensure the model validity. Further arm positions taken from activities of daily living, requiring the rotator cuff muscles were modeled and their contribution to joint kinetics computed. Weakness of the superior rotator cuff muscles (supraspinatus; infraspinatus) leads to a deviation of the joint reaction force to the cranial dorsal rim of the glenoid. Massive rotator cuff defects showed higher potential for glenohumeral instability in contrast to single muscle ruptures. The teres minor muscle seems to substitute lost joint torque during several simulated muscle tears to maintain joint stability. Joint instability increases with cuff tear size. Weakness of the upper part of the rotator cuff leads to a joint reaction force closer to the upper glenoid rim. This indicates the comorbidity of cuff tears with SLAP lesions. The teres minor is crucial for maintaining joint stability in case of massive cuff defects and should be uprated in clinical decision-making. © 2016 Orthopaedic Research Society. Published by Wiley Periodicals, Inc. J Orthop Res 34:1628-1635, 2016. © 2016 Orthopaedic Research Society. Published by Wiley Periodicals, Inc.
Patch-Augmented Rotator Cuff Repair and Superior Capsule Reconstruction
Petri, M.; Greenspoon, J.A.; Moulton, S.G.; Millett, P.J.
2016-01-01
Background: Massive rotator cuff tears in active patients with minimal glenohumeral arthritis remain a particular challenge for the treating surgeon. Methods: A selective literature search was performed and personal surgical experiences are reported. Results: For patients with irreparable rotator cuff tears, a reverse shoulder arthroplasty or a tendon transfer are often performed. However, both procedures have rather high complication rates and debatable long-term results, particularly in younger patients. Therefore, patch-augmented rotator cuff repair or superior capsule reconstruction (SCR) have been recently developed as arthroscopically applicable treatment options, with promising biomechanical and early clinical results. Conclusion: For younger patients with irreparable rotator cuff tears wishing to avoid tendon transfers or reverse total shoulder arthroplasty, both patch-augmentation and SCR represent treatment options that may delay the need for more invasive surgery. PMID:27708733
de-Azevedo-Vaz, Sergio Lins; Vasconcelos, Karla de Faria; Neves, Frederico Sampaio; Melo, Saulo Leonardo Sousa; Campos, Paulo Sérgio Flores; Haiter-Neto, Francisco
2013-01-01
To assess the accuracy of cone-beam computed tomography (CBCT) in periimplant fenestration and dehiscence detection, and to determine the effects of 2 voxel sizes and scan modes. One hundred titanium implants were placed in bovine ribs in which periimplant fenestration and dehiscence were simulated. CBCT images were acquired with the use of 3 protocols of the i-CAT NG unit: A) 0.2 mm voxel size half-scan (180°); B) 0.2 mm voxel size full-scan (360°); and C) 0.12 mm voxel size full scan (360°). Receiver operating characteristic curves and diagnostic values were obtained. The Az values were compared with the use of analysis of variance. The Az value for dehiscence in protocol A was significantly lower than those of B or C (P < .01). They did not statistically differ for fenestration (P > .05). Protocol B yielded the highest values. The voxel sizes did not affect fenestration and dehiscence detection, and for dehiscence full-scan performed better than half-scan. Copyright © 2013 Elsevier Inc. All rights reserved.
Rotator cuff strength balance in glovebox workers
Lawton, Cindy M.; Weaver, Amelia M.; Chan, Martha Kwan Yi; ...
2016-11-23
Gloveboxes are essential to the pharmaceutical, semi-conductor, nuclear, and biochemical industries. While gloveboxes serve as effective containment systems, they are often difficult to work in and present a number of ergonomic hazards. One such hazard is injury to the rotator cuff, a group of tendons and muscles in the shoulder, connecting the upper arm to the shoulder blade. Rotator cuff integrity is critical to shoulder health. This study compared the rotator cuff muscle strength ratios of glovebox workers to the healthy norm. Descriptive statistics were collected using a short questionnaire. Handheld dynamometry was used to quantify the ratio of forcesmore » produced for shoulder internal and external rotation. Results showed this population to have shoulder strength ratios significantly different from the healthy norm. Strength ratios were found to be a sound predictor of symptom incidence. The deviation from the normal ratio demonstrates the need for solutions designed to reduce the workload on the rotator cuff musculature in order to improve health and safety. Assessment of strength ratios can be used to screen for risk of symptom development. As a result, this increases technical knowledge and augments operational safety.« less
Rotator cuff strength balance in glovebox workers
DOE Office of Scientific and Technical Information (OSTI.GOV)
Lawton, Cindy M.; Weaver, Amelia M.; Chan, Martha Kwan Yi
Gloveboxes are essential to the pharmaceutical, semi-conductor, nuclear, and biochemical industries. While gloveboxes serve as effective containment systems, they are often difficult to work in and present a number of ergonomic hazards. One such hazard is injury to the rotator cuff, a group of tendons and muscles in the shoulder, connecting the upper arm to the shoulder blade. Rotator cuff integrity is critical to shoulder health. This study compared the rotator cuff muscle strength ratios of glovebox workers to the healthy norm. Descriptive statistics were collected using a short questionnaire. Handheld dynamometry was used to quantify the ratio of forcesmore » produced for shoulder internal and external rotation. Results showed this population to have shoulder strength ratios significantly different from the healthy norm. Strength ratios were found to be a sound predictor of symptom incidence. The deviation from the normal ratio demonstrates the need for solutions designed to reduce the workload on the rotator cuff musculature in order to improve health and safety. Assessment of strength ratios can be used to screen for risk of symptom development. As a result, this increases technical knowledge and augments operational safety.« less
Platelet-rich plasma for rotator cuff repair.
Barber, F Alan
2013-12-01
Rotator cuff tears are a common cause of shoulder pain and disability. Because they combine both traumatic and degenerative elements, the surgical repair can be challenging. Even after surgical intervention, tendon residual defects or "retears" often develop. Risk factors for tendon "retears" include patient age, number of tendons involved, tear size, and smoking. Platelet-rich plasma (PRP) is a supraphysiological concentration of platelets, which may be able to positively augment rotator cuff tendon healing. Not all PRPs are the same and those containing higher leukocyte levels may be detrimental to tendon healing. Thrombin activation triggers an immediate release of growth factors from the PRP and may actually inhibit some parts of the healing response. As yet, the clinical data does not conclusively prove a benefit from PRP, but discernment is required in evaluating the published results. As different PRPs may act differently and the results may be dose dependent requiring more PRP to achieve a beneficial threshold. How success is measured (clinical outcomes vs. intact cuff tendons) and how long the patients are followed are also critical items. Currently, the PRP fibrin matrix version holds the greatest promise for improving clinical success after rotator cuff tendon repair.
Control device for prosthetic urinary sphincter cuff
NASA Technical Reports Server (NTRS)
Reinicke, Robert H. (Inventor)
1983-01-01
A device for controlling flow of fluid to and from a resilient inflatable cuff implanted about the urethra to control flow of urine therethrough. The device comprises a flexible bulb reservoir and a control unit that includes a manually operated valve that opens automatically when the bulb is squeezed to force fluid into the cuff for closing the urethra. The control unit also includes a movable valve seat member having a relatively large area exposed to pressure of fluid in a chamber that is connected to the cuff and which moves to a position in which the valve member is unseated by an abutment when fluid pressure in the chamber exceeds a predetermined value to thereby relieve excess fluid pressure in the cuff. The arrangement is such that the valve element is held closed against the seat member by the full differential in fluid pressures acting on both sides of the valve element until the seat member is moved away from the valve element to thus insure positive closing of the valve element until the seat member is moved out of engagement with the valve element by excess pressure differential.
Ogawa, Mikihiro; Kay, Pippa; Wilson, Sarah; Swain, Stephen M.
2009-01-01
Cell separation is thought to involve degradation of pectin by several hydrolytic enzymes, particularly polygalacturonase (PG). Here, we characterize an activation tagging line with reduced growth and male sterility caused by increased expression of a PG encoded by QUARTET2 (QRT2). QRT2 is essential for pollen grain separation and is part of a small family of three closely related endo-PGs in the Arabidopsis thaliana proteome, including ARABIDOPSIS DEHISCENCE ZONE POLYGALACTURONASE1 (ADPG1) and ADPG2. Functional assays and complementation experiments confirm that ADPG1, ADPG2, and QRT2 are PGs. Genetic analysis demonstrates that ADPG1 and ADPG2 are essential for silique dehiscence. In addition, ADPG2 and QRT2 contribute to floral organ abscission, while all three genes contribute to anther dehiscence. Expression analysis is consistent with the observed mutant phenotypes. INDEHISCENT (IND) encodes a putative basic helix-loop-helix required for silique dehiscence, and we demonstrate that the closely related HECATE3 (HEC3) gene is required for normal seed abscission and show that IND and HEC3 are required for normal expression of ADPG1 in the silique dehiscence zone and seed abscission zone, respectively. We also show that jasmonic acid and ethylene act together with abscisic acid to regulate floral organ abscission, in part by promoting QRT2 expression. These results demonstrate that multiple cell separation events, including both abscission and dehiscence, require closely related PG genes. PMID:19168715
Rotator Cuff Disease and Injury--Evaluation and Management.
ERIC Educational Resources Information Center
Williams, Randy
This presentation considers the incidence, evaluation, and management of rotator cuff disease and injury. Pathogenesis, symptoms, physical findings, treatment (therapeutic and surgical), and prevention are discussed. It is noted that rotator cuff problems, common in athletes, are usually related to an error in training or lack of training. They…
Rotator cuff tendon connections with the rotator cable.
Rahu, Madis; Kolts, Ivo; Põldoja, Elle; Kask, Kristo
2017-07-01
The literature currently contains no descriptions of the rotator cuff tendons, which also describes in relation to the presence and characteristics of the rotator cable (anatomically known as the ligamentum semicirculare humeri). The aim of the current study was to elucidate the detailed anatomy of the rotator cuff tendons in association with the rotator cable. Anatomic dissection was performed on 21 fresh-frozen shoulder specimens with an average age of 68 years. The rotator cuff tendons were dissected from each other and from the glenohumeral joint capsule, and the superior glenohumeral, coracohumeral, coracoglenoidal and semicircular (rotator cable) ligaments were dissected. Dissection was performed layer by layer and from the bursal side to the joint. All ligaments and tendons were dissected in fine detail. The rotator cable was found in all specimens. It was tightly connected to the supraspinatus (SSP) tendon, which was partly covered by the infraspinatus (ISP) tendon. The posterior insertion area of the rotator cable was located in the region between the middle and inferior facets of the greater tubercle of the humerus insertion areas for the teres minor (TM), and ISP tendons were also present and fibres from the SSP extended through the rotator cable to those areas. The connection between the rotator cable and rotator cuff tendons is tight and confirms the suspension bridge theory for rotator cuff tears in most areas between the SSP tendons and rotator cable. In its posterior insertion area, the rotator cable is a connecting structure between the TM, ISP and SSP tendons. These findings might explain why some patients with relatively large rotator cuff tears can maintain seamless shoulder function.
Jahic, Mahira; Mulavdic, Mirsada; Nurkic, Jasmina; Jahic, Elmir; Nurkic, Midhat
2013-01-01
ABSTRACT Aim of the work: Examine clinical characteristics of aerobic vaginitis and mixed infection for the purpose of better diagnostic accuracy and treatment efficiency. Materials and methods: Prospective research has been conducted at Clinic for Gynecology and Obstetrics, Department for Microbiology and Pathology at Polyclinic for laboratory diagnostic and Gynecology and Obstetrics Department at Health Center Sapna. Examination included 100 examinees with the signs of vaginitis. Examination consisted of: anamnesis, clinical, gynecological and microbiological examination of vaginal smear. Results: The average age of the examinees was 32,62±2,6. Examining vaginal smears of the examinees with signs of vaginitis in 96% (N-96) different microorganisms have been isolated, while in 4% (N-4) findings were normal. AV has been found in 51% (N-51) of the examinees, Candida albicans in 17% (N-17), BV in 15% (N-15), Trichomonas vaginalis in 13% (N-13). In 21% (N-21) AV was diagnosed alone while associated with other agents in 30% (N-30). Most common causes of AV are E. coli (N-55) and E. faecalis (N-52). AV and Candida albicanis have been found in (13/30, 43%), Trichomonas vaginalis in (9/30, 30%) and BV (8/30, 26%). Vaginal secretion is in 70,05% (N-36) yellow coloured, red vagina wall is recorded in 31,13% (N-16) and pruritus in 72,54% (N-37). Increased pH value of vagina found in 94,10% (N-48). The average pH value of vaginal environment was 5,15±0,54 and in associated presence of AV and VVC, TV and BV was 5,29±0,56 which is higher value considering presence of AV alone but that is not statistically significant difference (p>0,05). Amino-odor test was positive in 29,94% (N-15) of associated infections. Lactobacilli are absent, while leukocytes are increased in 100% (N-51) of the examinees with AV. Conclusion: AV is vaginal infection similar to other vaginal infections. It is important to be careful while diagnosing because the treatment of AV differentiates from
Comparison of endotracheal tube cuff pressure values before and after training seminar.
Özcan, Ayça Tuba Dumanlı; Döğer, Cihan; But, Abdülkadir; Kutlu, Işık; Aksoy, Şemsi Mustafa
2018-06-01
It is recommended that endotracheal cuff (ETTc) pressure be between 20 and 30 cm H 2 O. In this present study, we intend to observe average cuff pressure values in our clinic and the change in these values after the training seminar. The cuff pressure values of 200 patients intubated following general anesthesia induction in the operating theatre were measured following intubation. One hundred patients whose values were measured before the training seminar held for all physician assistants, and 100 patients whose values were measured after the training seminar were regarded as Group 1 and Group 2, respectively. Cuff pressures of both groups were recorded, and the difference between them was shown. Moreover, cuff pressure values were explored according to the working period of the physician assistants. There was no significant difference between the groups in terms of age, gender and tube diameters. Statistically significant difference was found between cuff pressure values before and after the training (p < 0.001). Average pressure measure for Group I was 54 cm H 2 O, while average pressure in Group II declined to 33 cm H 2 O. It was observed that as the working period and experience of physician assistants increased, cuff pressure values decreased, however no statistically significant different was found (p < 0.375). We believe that clinical experience does not have significant effects on cuff pressure and that training seminars held at intervals would prevent high cuff pressure values and potential complications.
The role of platelet-rich plasma in rotator cuff repair.
Mei-Dan, Omer; Carmont, Michael R
2011-09-01
The shoulder is a common source of disability resulting from traumatic and degenerate tears of the rotator cuff, subacromial impingement, and osteoarthritis. Nonoperative management has focused on treatment of the predisposing factors, the use of analgesics and anti-inflammatory medication usually in association with local anesthetic and steroid injections. Surgical intervention allows debridement of the degenerate cuff and partial thickness cuff tears, subacromial bursitis, impinging bone spurs and osteophytes together with rotator cuff repairs. Repairs of degenerate and torn tissue are often prone to failure due to many intrinsic and extrinsic factors. It is assumed that some biological therapies might improve clinical, mechanical, and histologic outcomes. Injections of platelet-rich plasma (PRP) have led to reduced pain and improved recovery in other degenerate pathologies areas together with the restoration of function. This study reviews the current literature on PRP and in particular discusses its relevance in the treatment of rotator cuff tears.
Yeast infection (vaginal) Overview A vaginal yeast infection is a fungal infection that causes irritation, discharge and intense itchiness ... symptoms Causes The fungus candida causes a vaginal yeast infection. Your vagina naturally contains a balanced mix of yeast, including ...
Vitrectomy for optic disk pit with macular schisis and outer retinal dehiscence.
Shukla, Dhananjay; Kalliath, Jay; Tandon, Manish; Vijayakumar, Balakrishnan
2012-07-01
To describe the outcomes of vitrectomy for optic disc pit-related maculopathy with central outer retinal dehiscence. This prospective interventional case series included seven patients with optic disc pit with macular schisis and central outer retinal dehiscence who underwent vitrectomy with internal limiting membrane peeling, barrage laser photocoagulation, and gas tamponade and were followed for at least 6 months. The surgical outcomes in terms of restoration of macular anatomy and visual improvement were recorded at each visit by fundus photography and optical coherence tomography. The mean age of the patients was 21.3 ± 8.6 years (range, 10-35 years), and the mean duration of defective vision was 6.7 ± 8.5 months (range, 1-24 months). Preoperatively, the median best-corrected visual acuity (BCVA) was 20/60 (range, 20/40 to 20/120). Full-thickness macular holes were noticed in 4 patients 1 month postoperatively. Gas tamponade was repeated in two patients with large macular holes. By the final follow-up, macular holes had closed and BCVA improved in all patients except one. Final mean central macular thickness was 176.83 ± 55.74 μ, the range being 109 μ to 256 μ. The median postoperative BCVA was 20/30 (range, 20/20 to 20/80). Six of 7 patients (85.7%) had improvement in BCVA postoperatively (mean, +2 lines; range, 1-4 lines). Five patients (71%) achieved a postoperative BCVA of ≥20/30. Best-corrected visual acuity dropped by one line in the patient with persistent macular hole. Vitrectomy with internal limiting membrane peeling can achieve excellent final surgical outcomes in optic pit maculopathy with outer retinal dehiscence despite the potential for macular hole formation.
Improved apparatus for predictive diagnosis of rotator cuff disease
NASA Astrophysics Data System (ADS)
Pillai, Anup; Hall, Brittany N.; Thigpen, Charles A.; Kwartowitz, David M.
2014-03-01
Rotator cuff disease impacts over 50% of the population over 60, with reports of incidence being as high as 90% within this population, causing pain and possible loss of function. The rotator cuff is composed of muscles and tendons that work in tandem to support the shoulder. Heavy use of these muscles can lead to rotator cuff tear, with the most common causes is age-related degeneration or sport injuries, both being a function of overuse. Tears ranges in severity from partial thickness tear to total rupture. Diagnostic techniques are based on physical assessment, detailed patient history, and medical imaging; primarily X-ray, MRI and ultrasonography are the chosen modalities for assessment. The final treatment technique and imaging modality; however, is chosen by the clinician is at their discretion. Ultrasound has been shown to have good accuracy for identification and measurement of full-thickness and partial-thickness rotator cuff tears. In this study, we report on the progress and improvement of our method of transduction and analysis of in situ measurement of rotator cuff biomechanics. We have improved the ability of the clinician to apply a uniform force to the underlying musculotendentious tissues while simultaneously obtaining the ultrasound image. This measurement protocol combined with region of interest (ROI) based image processing will help in developing a predictive diagnostic model for treatment of rotator cuff disease and help the clinicians choose the best treatment technique.
Protection against rat vaginal candidiasis by adoptive transfer of vaginal B lymphocytes.
De Bernardis, Flavia; Santoni, Giorgio; Boccanera, Maria; Lucciarini, Roberta; Arancia, Silvia; Sandini, Silvia; Amantini, Consuelo; Cassone, Antonio
2010-06-01
Vulvovaginal candidiasis is a mucosal infection affecting many women, but the immune mechanisms operating against Candida albicans at the mucosal level remain unknown. A rat model was employed to further characterize the contribution of B and T cells to anti-Candida vaginal protection. Particularly, the protective role of vaginal B cells was studied by means of adoptive transfer of vaginal CD3(-) CD5(+) IgM(+) cells from Candida-immunized rats to naïve animals. This passive transfer of B cells resulted into a number of vaginal C. albicans CFU approximately 50% lower than their controls. Sorted CD3(-) CD5(+) IgM(+) vaginal B lymphocytes from Candida-infected rats proliferated in response to stimulation with an immunodominant mannoprotein (MP) antigen of the fungus. Importantly, anti-MP antibodies and antibody-secreting B cells were detected in the supernatant and cell cultures, respectively, of vaginal B lymphocytes from infected rats incubated in vitro with vaginal T cells and stimulated with MP. No such specific antibodies were found when using vaginal B cells from uninfected rats. Furthermore, inflammatory and anti-inflammatory cytokines, such as interleukin-2 (IL-2), IL-6 and IL-10, were found in the supernatant of vaginal B cells from infected rats. These data are evidence of a partial anti-Candida protective role of CD3(-) CD5(+) IgM(+) vaginal B lymphocytes in our experimental model.
Mendling, Werner
2016-01-01
The knowledge about the normal and abnormal vaginal microbiome has changed over the last years. Culturing techniques are not suitable any more for determination of a normal or abnormal vaginal microbiota. Non culture-based modern technologies revealed a complex and dynamic system mainly dominated by lactobacilli.The normal and the abnormal vaginal microbiota are complex ecosystems of more than 200 bacterial species influenced by genes, ethnic background and environmental and behavioral factors. Several species of lactobacilli per individuum dominate the healthy vagina. They support a defense system together with antibacterial substances, cytokines, defensins and others against dysbiosis, infections and care for an normal pregnancy without preterm birth.The numbers of Lactobacillus (L.) iners increase in the case of dysbiosis.Bacterial vaginosis (BV) - associated bacteria (BVAB), Atopobium vaginae and Clostridiales and one or two of four Gardnerella vaginalis - strains develop in different mixtures and numbers polymicrobial biofilms on the vaginal epithelium, which are not dissolved by antibiotic therapies according to guidelines and, thus, provoke recurrences.Aerobic vaginitis seems to be an immunological disorder of the vagina with influence on the microbiota, which is here dominated by aerobic bacteria (Streptococcus agalactiae, Escherichia coli). Their role in AV is unknown.Vaginal or oral application of lactobacilli is obviously able to improve therapeutic results of BV and dysbiosis.
Pulley lesions in rotator cuff tears: prevalence, etiology, and concomitant pathologies.
Hawi, Nael; Liodakis, Emmanouil; Garving, Christina; Habermeyer, Peter; Tauber, Mark
2017-08-01
This study aimed to demonstrate the prevalence of lesions in the biceps pulley complex in a representative, consecutive series of rotator cuff tears and rotator cuff interval treatments. We also analyzed associated tear pattern of rotator cuff injuries and superior labrum anterior-posterior (SLAP) lesions. We evaluated the relationships of these lesions to traumatic genesis and the prevalence of pulley lesions in revision cases. This retrospective study analyzed all pre- and intra-operative documentation on arthroscopic rotator cuff reconstructions and isolated pulley lesion treatments performed by a single surgeon over 2 consecutive years. According to Habermeyer et al., we classified cases into four groups, based on the presence of additional or related complete or partial rotator cuff tears, SLAP lesions, trauma, and primary or revision surgery. Among 382 patients with rotator cuff tears, 345 (90.3%) had an injured pulley system; 151 (43.8%) had partial tears of the rotator cuff; out of these, 106 (30.6%) were articular-sided. All of these articular-sided partial tears showed extension into the pulley complex. In 154 cases (44.6%), history of shoulder trauma was associated with the beginning of symptoms. In addition, concomitant SLAP lesions occurred in 25-62% of pulley lesions, correlating with the severity of pulley lesions. Among the 345 cases, there have been 32 (9.3%) revision cases where a pulley lesion was intra-operatively identified and addressed. Pulley complex lesions are present in 90.3% of surgically treated rotator cuff lesions, particularly in articular-sided injuries. In addition, we found a significant relationship between the incidence of SLAP lesions and the severity of pulley lesions. It seems reasonable to assume an important role of pulley system injuries in the pathogenesis of rotator cuff lesions.
Miraftabi, Arezoo; Nilforushan, Naveed
2016-01-01
Purpose: To report a complication pertaining to subconjunctival bevacizumab injection as an adjunct to Ahmed Glaucoma Valve (AGV) implantation. Case Report: A 54-year-old woman with history of complicated cataract surgery was referred for advanced intractable glaucoma. AGV implantation with adjunctive subconjunctival bevacizumab (1.25 mg) was performed with satisfactory results during the first postoperative week. However, 10 days after surgery, she developed wound dehiscence and tube exposure. The second case was a 33-year-old man with history of congenital glaucoma and uncontrolled IOP who developed AGV exposure and wound dehiscence after surgery. In both cases, for prevention of endophthalmitis and corneal damage by the unstable tube, the shunt was removed and the conjunctiva was re-sutured. Conclusion: The potential adverse effect of subconjunctival bevacizumab injection on wound healing should be considered in AGV surgery. PMID:27195095
Sethi, Paul M; Sheth, Chirag D; Pauzenberger, Leo; McCarthy, Mary Beth R; Cote, Mark P; Soneson, Emma; Miller, Seth; Mazzocca, Augustus D
2018-03-01
Numerous studies have identified factors that may affect the chances of rotator cuff healing after surgery. Intraoperative tendon quality may be used to predict healing and to determine type of repair and/or consideration of augmentation. There are no data that correlate how gross tendon morphology and degree of tendinopathy affect patient outcome or postoperative tendon healing. Purpose/Hypothesis: The purposes of this study were to (1) compare the gross appearance of the tendon edge during arthroscopic rotator cuff repair with its histological degree of tendinopathy and (2) determine if gross appearance correlated with postoperative repair integrity. The hypothesis was that gross (macroscopic) tendon with normal thickness, no delamination, and elastic tissue before repair would have a correlation with low Bonar scores, higher postoperative American Shoulder and Elbow Surgeons (ASES) scores, and increased rates of postoperative tendon healing on ultrasound. Cross-sectional study; Level of evidence, 3. A total of 105 patients undergoing repair of medium-size (1-3 cm) full-thickness rotator cuff tears were enrolled in the study. Intraoperatively, the supraspinatus tendon was rated on thickness, fraying, and stiffness. Tendon tissue was recovered for histological analysis based on the Bonar scoring system. Postoperative ASES and ultrasound assessment of healing were obtained 1 year after repair. Correlation between gross appearance of the tendon and rotator cuff histology was determined. Of the 105 patients, 85 were followed the study to completion. The mean age of the patients was 61.6 years; Bonar score, 7.5; preoperative ASES score, 49; and postoperative ASES score, 86. Ninety-one percent of repairs were intact on ultrasound. Gross appearance of torn rotator cuff tendon tissue did not correlate with histological appearance. Neither histological (Bonar) score nor gross appearance correlated with multivariate analysis of ASES score, postoperative repair status, or
The Biomechanical Role of Scaffolds in Augmented Rotator Cuff Tendon Repairs
2012-01-01
failure loads of a human dermal allograft rotator cuff augmentation. Arthroscopy 2008;24:20-4. doi:10.1016/j.arthro.2007.07.013 5. Bartolozzi A...of the cuff. J Bone Joint Surg Am 1991;73-A:982-9. 17. Ide J, Maeda S, Takagi K. A comparison of arthroscopic and open rotator cuff repair. Arthroscopy
Endotracheal Tube Cuff Pressures in Patients Intubated Prior to Helicopter EMS Transport.
Tennyson, Joseph; Ford-Webb, Tucker; Weisberg, Stacy; LeBlanc, Donald
2016-11-01
Endotracheal intubation is a common intervention in critical care patients undergoing helicopter emergency medical services (HEMS) transportation. Measurement of endotracheal tube (ETT) cuff pressures is not common practice in patients referred to our service. Animal studies have demonstrated an association between the pressure of the ETT cuff on the tracheal mucosa and decreased blood flow leading to mucosal ischemia and scarring. Cuff pressures greater than 30 cmH 2 O impede mucosal capillary blood flow. Multiple prior studies have recommended 30 cmH 2 O as the maximum safe cuff inflation pressure. This study sought to evaluate the inflation pressures in ETT cuffs of patients presenting to HEMS. We enrolled a convenience sample of patients presenting to UMass Memorial LifeFlight who were intubated by the sending facility or emergency medical services (EMS) agency. Flight crews measured the ETT cuff pressures using a commercially available device. Those patients intubated by the flight crew were excluded from this analysis as the cuff was inflated with the manometer to a standardized pressure. Crews logged the results on a research form, and we analyzed the data using Microsoft Excel and an online statistical analysis tool. We analyzed data for 55 patients. There was a mean age of 57 years (range 18-90). The mean ETT cuff pressure was 70 (95% CI= [61-80]) cmH 2 O. The mean lies 40 cmH 2 O above the maximum accepted value of 30 cmH 2 O (p<0.0001). Eighty-four percent (84%) of patients encountered had pressures above the recommended maximum. The most frequently recorded pressure was >120 cmH 2 O, the maximum pressure on the analog gauge. Patients presenting to HEMS after intubation by the referral agency (EMS or hospital) have ETT cuffs inflated to pressures that are, on average, more than double the recommended maximum. These patients are at risk for tracheal mucosal injury and scarring from decreased mucosal capillary blood flow. Hospital and EMS providers should
Risk Factors for Infection After Rotator Cuff Repair.
Vopat, Bryan G; Lee, Bea J; DeStefano, Sherilyn; Waryasz, Gregory R; Kane, Patrick M; Gallacher, Stacey E; Fava, Joseph; Green, Andrew G
2016-03-01
To identify risk factors for infection after rotator cuff repair. We hypothesized that patient characteristics and surgical technique would affect the rate of infection. The records of 1,824 rotator cuff repairs performed by a single surgeon from 1995 to 2010 were reviewed retrospectively. Fourteen patients had an early deep postoperative wound infection that was treated with surgical irrigation and debridement. One hundred eighty-five control patients who were treated with rotator cuff repair and did not develop an infection were selected randomly for comparison and statistical analysis. Data regarding preoperative and intraoperative risk factors for infection were recorded, and a multiple logistic regression was conducted to investigate predictors of infection. The infection rate was 0.77% (14/1,822). On average 2.1 (range 1 to 4) surgical debridements were performed in addition to treatment with intravenous antibiotics. Patients who had open or miniopen rotator cuff repair had a significantly greater risk of acute postoperative infection (odds ratio [OR] = 8.63, P = .002). Seventy-nine percent of the patients in the infection group had an open or miniopen repair, whereas only 28% of the control group had an open or miniopen repair. Male patients also had a significantly greater risk of acute postoperative infection (OR = 9.52, P = .042). A total of 92% of the infection patients were male compared with 58% of the control group. In addition, as body mass index increased there was a reduction in the odds of infection (OR = 0.81, P = .023). The results of this case control study demonstrate that open or miniopen surgical technique and male sex are significant risk factors for infection after rotator cuff repair. In our study, arthroscopic rotator cuff repair reduced the risk of infection compared with open techniques. Level IV. Copyright © 2016 Arthroscopy Association of North America. Published by Elsevier Inc. All rights reserved.
Rotator cuff tear and sarcopenia: are these related?
Chung, Seok Won; Yoon, Jong Pil; Oh, Kyung-Soo; Kim, Hyung Sup; Kim, Young Gun; Lee, Hyun-Joo; Jeong, Won-Ju; Kim, Dong-Hyun; Lee, Jong Soo; Yoon, Jee Wook
2016-09-01
Sarcopenia is the loss of muscle mass and consequent loss of muscle function with aging. Its prevalence among the general population is 12% to 30% in those aged >60 years. We evaluated (1) the difference in the prevalence of sarcopenia between patients with rotator cuff tear and controls and (2) the sarcopenia severity according to the size of the rotator cuff tear. Group 1 included 48 consecutive patients with chronic symptomatic full-thickness rotator cuff tears (mean age, 60.1 ± 6.5 years; range, 46-76 years), and group 2 included 48 age- and sex-matched patients. The sarcopenic index was evaluated by using the grip strength of the asymptomatic contralateral side and the skeletal muscle mass. No significant differences were found in the baseline data and demographic factors between the groups. The sarcopenic index was significantly inferior in the rotator cuff tear group than in the age- and sex-matched control groups (P = .041, .007, and .05, respectively). Patients with large to massive tears had a significantly inferior sarcopenic index than those with small and medium tears. The results showed that sarcopenia was more severe in patients with a chronic symptomatic full-thickness rotator cuff tear than in the age- and sex-matched control population and was correlated with the size of the tear, with the numbers available. Despite the individual variance in the underlying medical condition and physical activities, this study suggests that clinicians should consider the sarcopenic condition of patients with a rotator cuff tear, especially in elderly patients with large to massive tears. Copyright © 2016 Journal of Shoulder and Elbow Surgery Board of Trustees. Published by Elsevier Inc. All rights reserved.
Functional outcomes after bilateral arthroscopic rotator cuff repair.
Aleem, Alexander W; Syed, Usman Ali M; Wascher, Jocelyn; Zoga, Adam C; Close, Koby; Abboud, Joseph A; Cohen, Steven B
2016-10-01
Arthroscopic repair of rotator cuff tears is a common procedure performed by orthopedic surgeons. There is a well-known incidence of up to 35% of bilateral rotator cuff tear disease in patients who have a known unilateral tear. The majority of the literature focuses on outcomes after unilateral surgery. The purpose of this study was to determine if there are clinical differences in shoulders of patients who underwent staged bilateral rotator cuff repairs during their lifetime. A retrospective review of all patients who underwent staged bilateral arthroscopic rotator cuff surgery at our institution was performed. All patients had at least 2 years of follow-up. Clinical outcome scores including the American Shoulder and Elbow Surgeons (ASES), Single Assessment Numeric Evaluation, and Rowe measures were obtained. A subset of patients returned for clinical and ultrasound evaluation performed by an independent fellowship-trained musculoskeletal radiologist. Overall, 110 shoulders in 55 patients, representing 68% of all eligible patients, participated. No clinical or statistical difference was found in any outcome measure. ASES scores averaged 86.5 (36.7-100) in the dominant shoulder compared with 89.6 (23.3-100) in the nondominant shoulder (P = .42). Ultrasound was available on 34 shoulders and showed complete healing rate of 88%. The shoulders with retearing of the rotator cuff (12%) demonstrated clinically relevant lower ASES scores (72.5) compared with shoulders with confirmed healed repairs (86.2; P = .2). Patients who undergo staged bilateral rotator cuff repair can expect to have similarly good clinical outcomes regardless of hand dominance or chronologic incidence with excellent healing rates in both shoulders. Copyright © 2016 Journal of Shoulder and Elbow Surgery Board of Trustees. Published by Elsevier Inc. All rights reserved.
Vaginal Cancer—Patient Version
Two-thirds of vaginal cancer cases are caused by human papillomavirus (HPV). Vaccines that protect against infection with HPV may reduce the risk of vaginal cancer. When found early, vaginal cancer can often be cured. Start here to find information on vaginal cancer treatment and research.
Brody, Stuart; Klapilova, Katerina; Krejčová, Lucie
2013-07-01
Research indicated that: (i) vaginal orgasm (induced by penile-vaginal intercourse [PVI] without concurrent clitoral masturbation) consistency (vaginal orgasm consistency [VOC]; percentage of PVI occasions resulting in vaginal orgasm) is associated with mental attention to vaginal sensations during PVI, preference for a longer penis, and indices of psychological and physiological functioning, and (ii) clitoral, distal vaginal, and deep vaginal/cervical stimulation project via different peripheral nerves to different brain regions. The aim of this study is to examine the association of VOC with: (i) sexual arousability perceived from deep vaginal stimulation (compared with middle and shallow vaginal stimulation and clitoral stimulation), and (ii) whether vaginal stimulation was present during the woman's first masturbation. A sample of 75 Czech women (aged 18-36), provided details of recent VOC, site of genital stimulation during first masturbation, and their recent sexual arousability from the four genital sites. The association of VOC with: (i) sexual arousability perceived from the four genital sites and (ii) involvement of vaginal stimulation in first-ever masturbation. VOC was associated with greater sexual arousability from deep vaginal stimulation but not with sexual arousability from other genital sites. VOC was also associated with women's first masturbation incorporating (or being exclusively) vaginal stimulation. The findings suggest (i) stimulating the vagina during early life masturbation might indicate individual readiness for developing greater vaginal responsiveness, leading to adult greater VOC, and (ii) current sensitivity of deep vaginal and cervical regions is associated with VOC, which might be due to some combination of different neurophysiological projections of the deep regions and their greater responsiveness to penile stimulation. © 2013 International Society for Sexual Medicine.
Apoptosis occurs throughout the diseased rotator cuff.
Lee, Hyo-Jin; Kim, Yang-Soo; Ok, Ji-Hoon; Song, Ha-Jung
2013-10-01
Even though apoptosis is known to be closely associated with rotator cuff tears, the differences in apoptosis according to the location within the torn supraspinatus tendon are still unknown. To elucidate where apoptosis begins within the supraspinatus tendon. Controlled laboratory study. Tendon tissues were collected from 14 patients undergoing arthroscopic rotator cuff repair surgery and 7 patients undergoing surgery for proximal humeral fracture who served as controls. In the patients with rotator cuff tears, the samples were harvested at 3 sites: the most lateral torn margin, 1 cm medial from the torn margin, and at the posterior torn corner. Caspase 3/7, 8, and 9 and cytochrome c activities were measured to determine the intracellular apoptosis pathway. Apoptotic cells were determined by in situ TUNEL (terminal deoxynucleotidyltransferase-mediated dUTP-biotin nick end labeling) staining, and immunohistochemistry was performed. The apoptotic activities of tendons from the experimental subjects were significantly higher than those of the controls. There were, however, no significant differences between the 3 sample sites. Immunohistochemistry also revealed strong expression of increased caspase 3/7, 8, and 9 and cytochrome c but no significant difference between them. This study shows that the intracellular apoptotic pathway is not only through the cell membrane receptor but also via intracellular mitochondria cascade. Because apoptosis occurs regardless of the location within the rotator cuff, debridement of the torn margin to obtain a healthy tendon may not be needed. Further study should focus on not only the technique of tying the torn tendon back to the bone but also biological augmentation to reverse or prevent further apoptosis within rotator cuff tendon.
Management of aerobic vaginitis.
Tempera, Gianna; Furneri, Pio Maria
2010-01-01
Aerobic vaginitis is a new nonclassifiable pathology that is neither specific vaginitis nor bacterial vaginosis. The diversity of this microbiological peculiarity could also explain several therapeutic failures when patients were treated for infections identified as bacterial vaginosis. The diagnosis 'aerobic vaginitis' is essentially based on microscopic examinations using a phase-contrast microscope (at ×400 magnification). The therapeutic choice for 'aerobic vaginitis' should take into consideration an antibiotic characterized by an intrinsic activity against the majority of bacteria of fecal origin, bactericidal effect and poor/absent interference with the vaginal microbiota. Regarding the therapy for aerobic vaginitis when antimicrobial agents are prescribed, not only the antimicrobial spectrum but also the presumed ecological disturbance on the anaerobic and aerobic vaginal and rectal microbiota should be taken into a consideration. Because of their very low impact on the vaginal microbiota, kanamycin or quinolones are to be considered a good choice for therapy. Copyright © 2010 S. Karger AG, Basel.
Rotator cuff tendinopathy: a model for the continuum of pathology and related management.
Lewis, Jeremy S
2010-10-01
Pathology of the soft tissues of the shoulder including the musculotendinous rotator cuff and subacromial bursa are extremely common and are a principal cause of pain and suffering. Competing theories have been proposed to explain the pathoaetiology of rotator cuff pathology at specific stages and presentations of the condition. This review proposes a model to describe the continuum of the rotator cuff pathology from asymptomatic tendon through full thickness rotator cuff tears. The pathoaetiology of rotator cuff failure is multifactorial and results from a combination of intrinsic, extrinsic and environmental factors. Recently a new and generic model detailing the continuum of tendon pathology has been proposed. This model is relevant for the rotator cuff and provides a framework to stage the continuity of rotator cuff pathology. Furthermore, it provides a structure to identify the substantial deficiencies in our knowledge base and areas where research would improve our understanding of the pathological and repair process, together with assessment and management. The strength of this model adapted for the rotator cuff tendons and subacromial bursa will be tested in its ability to incorporate and adapt to emerging research.
Model-based evaluation of the short-circuited tripolar cuff configuration.
Andreasen, Lotte N S; Struijk, Johannes J
2006-05-01
Recordings of neural information for use as feedback in functional electrical stimulation are often contaminated with interfering signals from muscles and from stimulus pulses. The cuff electrode used for the neural recording can be optimized to improve the S/I ratio. In this work, we evaluate a model of both the nerve signal and the interfering signals recorded by a cuff, and subsequently use this model to study the signal to interference ratio of different cuff designs and to evaluate a recently introduced short-circuited tripolar cuff configuration. The results of the model showed good agreement with results from measurements in rabbits and confirmed the superior performance of the short-circuited tripolar configuration as compared with the traditionally used tripolar configuration.
The diagnosis of aortoiliac disease. A noninvasive femoral cuff technique.
Barringer, M; Poole, G V; Shircliffe, A C; Meredith, J W; Hightower, F; Plonk, G W
1983-01-01
An inexpensive femoral "cuff" developed in this noninvasive vascular laboratory allows pulse volume recordings and systolic pressure measurements of the femoral arteries. Using the parameters 1) femoral/brachial systolic pressure ratio, 2) wave amplitude, and 3) status of the dicrotic notch for assessment of results, it was found that the cuff correctly identified 59 of 62 limbs with at least 50% aortoiliac stenosis, with only two false-positive results, for an accuracy of 97%. The high, wide thigh cuff identified 57 of the 62 limbs, but had 45 false-positive results (77% accuracy). Use of the femoral "cuff" has refined the ability to identify the anatomic location of significant arterial stenoses in the lower extremities. Images Fig. 1. Fig. 2. PMID:6824373
Bone mineralization changes of the glenoid in shoulders with symptomatic rotator cuff tear.
Harada, Yohei; Yokoya, Shin; Akiyama, Yuji; Mochizuki, Yu; Ochi, Mitsuo; Adachi, Nobuo
2018-06-06
Computed tomography osteoabsorptiometry (CTO) is a method to analyze the stress distribution in joints by measuring the subchondral bone density. The purpose of this study was to evaluate the bone mineralization changes of the glenoid in shoulders with rotator cuff tears by CTO and to evaluate whether rotator cuff tears are associated with stress changes in the glenoid. In total, 32 patients, who were diagnosed with unilateral rotator cuff tears and underwent arthroscopic rotator cuff repair, were enrolled in this study. They underwent CT scanning of both shoulders pre-operatively and the glenoid was evaluated using CTO. Hounsfield units (HU) in seven areas of the glenoid were compared between the affected and unaffected sides. The central area of the glenoid on the affected side had significantly lower HU than on the unaffected side among all patients. Focusing on the rotator cuff tear size and the subscapularis tendon, only patients with larger cuff tears or with subscapularis tendon tears showed significantly lower HU in the central area of the affected side. This study showed a decrease in bone mineralization density in the central glenoid in shoulders with rotator cuff tear. This change was observed in the case of larger cuff tears and subscapularis tendon tears. Our results help clarify the changes in stress distribution in the shoulder joint caused by symptomatic rotator cuff tears.
Comparison between Two Endotracheal Tube Cuff Inflation Methods; Just-Seal Vs. Stethoscope-Guided.
Borhazowal, Rishiraj; Harde, Minal; Bhadade, Rakesh; Dave, Sona; Aswar, Swapnil Ganeshrao
2017-06-01
The Endotracheal Tube (ETT) cuff performs a critical function of sealing the airway during positive pressure ventilation. There is a narrow range of cuff pressure required to maintain a functionally safe seal without exceeding capillary blood pressure. We aimed to compare Just-Seal (JS) and Stethoscope-Guided (SG) method of ETT cuff inflation with respect to the volume of air required to inflate the cuff, the manometric cuff pressure achieved and also to assess for the occurrence of postoperative sore throat after extubation in both the groups. It was a prospective observational study done in a Tertiary Teaching Public Hospital over a period of 1½ years on 100 patients with 50 each in two groups; JS or SG method of cuff inflation. SPSS Version 17 was used for data analysis. Statistically significant difference (p-value of less than 0.05) was noted between the two methods based on the volume of air injected into the cuff {the mean volume injected in JS was 6.79 ml and in the SG was 4.95 ml with p=5.71E-16 (< 0.05)} and cuff pressure achieved {mean cuff pressure achieved was 38.80 cm H 2 O in the JS and 29.64 cm H 2 O in SG with p=2.29E-14 (< 0.05)}. The incidence of post extubation sore throat was 54% (27 in 50) in the JS group and only 12% (6 in 50) in the SG; p= 0.00000797. ETT cuff inflation guided by a stethoscope is an effective technique for ensuring appropriate cuff pressures thus accomplishing the objective of providing safe and superior quality care of the patient both during and after anaesthesia and reducing the likelihood of even minimal risk complications that may still have legal implications.
Kim, Min-Soo; Lee, Jeong-Rim; Shin, Yang-Sik; Chung, Ji-Won; Lee, Kyu-Ho; Ahn, Ki Ryang
2014-03-01
This single-center, prospective, randomized, double-blind, 2-arm, parallel group comparison trial was performed to establish whether the adult-sized laryngeal mask airway (LMA) Classic (The Laryngeal Mask Company Ltd, Henley-on-Thames, UK) could be used safely without any consideration of cuff hyperinflation when a cuff of the LMA Classic was inflated using half the maximum inflation volume or the resting volume before insertion of device. Eighty patients aged 20 to 70 years scheduled for general anesthesia using the LMA Classic were included. Before insertion, the cuff was partially filled with half the maximum inflation volume in the half volume group or the resting volume created by opening the pilot balloon valve to equalize with atmospheric pressure in the resting volume group. Several parameters regarding insertion, intracuff pressure, airway leak pressure, and leakage volume/fraction were collected after LMA insertion. The LMA Classic with a partially inflated cuff was successfully inserted in all enrolled patients. Both groups had the same success rate of 95% at the first insertion attempt. The half volume group had a lower mean intracuff pressure compared with the resting volume group (54.5 ± 16.1 cm H2O vs 61.8 ± 16.1 cm H2O; P = .047). There was no difference in airway leak pressure or leakage volume/fraction between the 2 groups under mechanical ventilation. The partially inflated cuff method using half the maximum recommended inflation volume or the resting volume is feasible with the adult-sized LMA Classic, resulting in a high success rate of insertion and adequate range of intracuff pressures. Copyright © 2014 Elsevier Inc. All rights reserved.
The effect of glenoid cavity depth on rotator cuff tendinitis.
Malkoc, Melih; Korkmaz, Ozgur; Ormeci, Tugrul; Sever, Cem; Kara, Adna; Mahirogulları, Mahir
2016-03-01
Some of the most important causes of shoulder pain are inflammation and degenerative changes in the rotator cuff (RC). Magnetic resonance imaging (MRI) is a noninvasive and safe imaging modality. MRI can be used for the evaluation of cuff tendinopathy. In this study, we evaluated the relationship between glenoid cavity depth and cuff tendinopathy and we investigated glenoid cavity depth on the pathogenesis of cuff tendinopathy. We retrospectively evaluated 215 patients who underwent MRI. Of these, 60 patients showed cuff tendinopathy (group A) and 54 patients showed no pathology (group B). Glenoid cavity depth was calculated in the coronal and transverse planes. The mean axial depth was 1.7 ± 0.9 and the mean coronal depth 3.8 ± 0.9, for group A. The mean axial depth was 3.5 ± 0.7 and the mean coronal depth 1.5 ± 0.8, for group B. There were significant differences in the axial and coronal depths between the two groups. High coronal and low axial depth of the glenoid cavity can be used to diagnose RC tendinitis.
Natural History of Rotator Cuff Disease and Implications on Management
Hsu, Jason
2015-01-01
Degenerative rotator cuff disease is commonly associated with ageing and is often asymptomatic. The factors related to tear progression and pain development are just now being defined through longitudinal natural history studies. The majority of studies that follow conservatively treated painful cuff tears or asymptomatic tears that are monitored at regular intervals show slow progression of tear enlargement and muscle degeneration over time. These studies have highlighted greater risks for disease progression for certain variables, such as the presence of a full-thickness tear and involvement of the anterior aspect supraspinatus tendon. Coupling the knowledge of the natural history of degenerative cuff tear progression with variables associated with greater likelihood of successful tendon healing following surgery will allow better refinement of surgical indications for rotator cuff disease. In addition, natural history studies may better define the risks of nonoperative treatment over time. This article will review pertinent literature regarding degenerative rotator cuff disease with emphasis on variables important to defining appropriate initial treatments and refining surgical indications. PMID:26726288
Ultrasound-Guided Prolotherapy with Polydeoxyribonucleotide for Painful Rotator Cuff Tendinopathy.
Ryu, Kyoungho; Ko, Dongchan; Lim, Goeun; Kim, Eugene; Lee, Sung Hyun
2018-01-01
Rotator cuff tendinopathy is a primary cause of shoulder pain and dysfunction. Several effective nonsurgical treatment methods have been described for chronic rotator cuff tendinopathy. Prolotherapy with polydeoxyribonucleotide (PDRN), which consists of active deoxyribonucleotide polymers that stimulate tissue repair, is a nonsurgical regenerative injection that may be a viable treatment option. The objective of this study was to assess the efficacy of PDRN in the treatment of chronic rotator cuff tendinopathy. The records of patients with chronic rotator cuff tendinopathy ( n =131) were reviewed retrospectively, and the patients treated with PDRN prolotherapy ( n =32) were selected. We measured the main outcome of the shoulder pain and disability index score on a numerical rating scale of average shoulder pain. Compared with baseline data, significant improvements in the shoulder pain and disability index and pain visual analog scale scores were demonstrated at one week after the end of treatment, and at one month and three months later. PDRN prolotherapy may improve the conservative treatment of painful rotator cuff tendinopathy for a specific subset of patients.
... bleeding is any vaginal bleeding unrelated to normal menstruation. This type of bleeding may include spotting of ... two or more hours. Normal vaginal bleeding, or menstruation, occurs every 21 to 35 days when the ...
... usually don't cause vaginal odors. Neither do yeast infections. Generally, if you have vaginal odor without ... Avoid douching. All healthy vaginas contain bacteria and yeast. The normal acidity of your vagina keeps bacteria ...
... an infection caused by an overgrowth of harmful bacteria in the vagina). Clindamycin is in a class ... works by slowing or stopping the growth of bacteria. Vaginal clindamycin cannot be used to treat vaginal ...
Vaginal problems are some of the most common reasons women go to the doctor. They may have ... common problem is vaginitis, an inflammation of the vagina. Other problems that affect the vagina include sexually ...
[Analysis on risk factors of endotracheal cuff under inflation in mechanically ventilated patients].
Fu, You; Xi, Xiuming
2014-12-01
To investigate the prevalent condition of endotracheal cuff pressure and risk factors for under inflation. A prospective cohort study was conducted. Patients admitted to the Department of Critical Care Medicine of Fuxing Hospital Affiliated to Capital Medical University, who were intubated with a high-volume low-pressure endotracheal tube, and had undergone mechanical ventilation for at least 48 hours, were enrolled. The endotracheal cuff pressure was determined every 8 hours by a manual manometer connected to the distal edge of the valve cuff at 07 : 00, 15 : 00, and 23 : 00. Measurement of the endotracheal cuff pressure was continued until the extubation of endotracheal or tracheostomy tube, or death of the patient. According to the incidence of under inflation of endotracheal cuff, patients were divided into the incidence of under inflation lower than 25% group (lower low cuff pressure group) and higher than 25% group (higher low cuff pressure group). The possible influencing factors were evaluated in the two groups, including body mass index (BMI), size of endotracheal tube, duration of intubation, use of sedative or analgesic, number of leaving from intensive care unit (ICU), the number of turning over the patients, and aspiration of sputum. Logistic regression analysis was used to determine risk factors for under-inflation of the endotracheal cuff. During the study period, 53 patients were enrolled. There were 812 measurements, and 46.3% of them was abnormal, and 204 times (25.1%) of under inflation of endotracheal cuff were found. There were 24 patients (45.3%) in whom the incidence of under inflation rate was higher than 25%. The average of under inflation was 7 (4, 10) times. Compared with the group with lower rate of low cuff pressure, a longer time for intubation was found in group with higher rate of low cuff pressure [hours: 162 (113, 225) vs. 118 (97, 168), Z=-2.034, P=0.042]. There were no differences between the two groups in other factors
Identification of a genetic variant associated with rotator cuff repair healing.
Tashjian, Robert Z; Granger, Erin K; Zhang, Yue; Teerlink, Craig C; Cannon-Albright, Lisa A
2016-06-01
A familial and genetic predisposition for the development of rotator cuff tearing has been identified. The purpose of this study was to determine if a familial predisposition exists for healing after rotator cuff repair and if the reported significant association with a single-nucleotide polymorphism (SNP) in the ESRRB gene is present in patients who fail to heal. The study recruited 72 patients undergoing arthroscopic rotator cuff repair for a full-thickness posterosuperior tear. Magnetic resonance imaging studies were performed at a minimum of 1 year postoperatively (average, 2.6 years). Healing failures were classified as lateral or medial. Self-reported family history of rotator cuff tearing data and genome-wide genotypes were available. Characteristics of cases with and without a family history of rotator cuff tearing were compared, and a comparison of the frequency of SNP 1758384 (in ESRRB) was performed between patients who healed and those who failed to heal. Of the rotator cuff repairs, 42% failed to heal; 42% of patients reported a family history of rotator cuff tear. Multivariate regression analysis showed a significant association between familiality and overall healing failure (medial and lateral failures) (P = .036) and lateral failures independently (P = .006). An increased risk for the presence of a rare allele for SNP rs17583842 was present in lateral failures compared with those that healed (P = .005). Individuals with a family history of rotator cuff tearing were more likely to have repair failures. Significant association of a SNP variant in the ESRRB gene was also observed with lateral failure. Copyright © 2016 Journal of Shoulder and Elbow Surgery Board of Trustees. Published by Elsevier Inc. All rights reserved.
No prosthetic management of massive and irreparable rotator cuff tears
Garofalo, Raffaele; Cesari, Eugenio
2014-01-01
A massive rotator cuff tear is not necessarily irreparable. Number of tendons involved, muscle-tendon unit quality, and decreased acromionhumeral distance (AHD) are as important as tear size in determining reparability of lesion. Massive and irreparable rotator cuff tears cannot be anatomically repaired to the bone and are a common source of pain and disability even in middle-aged patients. In these patients when conservative management has failed, it is possible to perform different surgical techniques. A functional repair can help to restore the horizontal force couple of the cuff on the humeral head and to increase the AHD. Debridement of irreparable tears and biceps tenotomy or tenodesis can have a role in low functional demand patients but results deteriorate over time. Recently, several commercially available tissue-engineered biological and synthetic scaffolds have been developed to augment rotator cuff repairs. The aim is to provide a mechanical improvement in case of poor quality tissue at time zero and give a support to have a better cuff healing. In selected cases, the scaffold can be used also to bridge tendon defect. Patients who not have pseudoparalysis, cuff tear arthropathy and with intact deltoid function can benefit from tendon transfers with satisfactory outcomes. These different procedures should be chosen for each patient with selected criteria and after a satisfactory explanation about the really possible expectation after surgery. PMID:27582930
Liu, Yu; Wang, Yi-Feng
2017-07-01
We report a case of successful vaginal delivery after vaginal reconstruction with labium minus flaps in a 23-year-old patient with congenital vaginal atresia. The patient primarily presented with amenorrhea and cyclic abdominal pain; transabdominal ultrasonography revealed an enlarged uterus due to hematometra and absence of the lower segment of the vagina. Eight years ago, she had undergone an unsuccessful attempt at canalization at a local hospital. Upon referral to our hospital, she underwent vaginal reconstruction with labium minus flaps. Four months after this procedure, she became pregnant and, subsequently, successfully and safely vaginally delivered a healthy female baby weighing 3250 g at 38 +1 weeks' gestation. The delivery did not involve perineal laceration by lateral episiotomy. To the best of our knowledge, this is the first reported case of successful vaginal delivery at term after vaginal reconstruction with labium minus flaps in a patient with vaginal atresia. © 2017 Japan Society of Obstetrics and Gynecology.
Donders, Gilbert G G; Vereecken, Annie; Bosmans, Eugene; Dekeersmaecker, Alfons; Salembier, Geert; Spitz, Bernard
2002-01-01
To define an entity of abnormal vaginal flora: aerobic vaginitis. Observational study. University Hospital Gasthuisberg, Leuven, Belgium. 631 women attending for routine prenatal care or attending vaginitis clinic. Samples were taken for fresh wet mount microscopy of vaginal fluid, vaginal cultures and measurement of lactate, succinate and cytokine levels in vaginal fluid. Smears deficient in lactobacilli and positive for clue cells were considered to indicate a diagnosis of bacterial vaginosis. Aerobic vaginitis was diagnosed if smears were deficient in lactobacilli, positive for cocci or coarse bacilli, positive for parabasal epithelial cells, and/or positive for vaginal leucocytes (plus their granular aspect). Genital complaints include red inflammation, yellow discharge, vaginal dyspareunia. Group B streptococci, escherichia coli, staphylococcus aureus and trichomonas vaginalis are frequently cultured. Vaginal lactate concentration is severely depressed in women with aerobic vaginitis, as in bacterial vaginosis, but vaginal succinate is not produced. Also in contrast to bacterial vaginosis, aerobic vaginitis produces a host immune response that leads to high production of interleukin-6, interleukin-1-beta and leukaemia inhibitory factor in the vaginal fluid. Aerobic vaginitis is associated with aerobic micro-organisms, mainly group B streptococci and E. coli. Its characteristics are different from those of bacterial vaginosis and elicit an important host response. The most severe form of aerobic vaginitis equals desquamative inflammatory vaginitis. In theory, aerobic vaginitis may be a better candidate than bacterial vaginosis as the cause of pregnancy complications, such as ascending chorioamnionitis, preterm rupture of the membranes and preterm delivery.
Immobilization After Rotator Cuff Repair: What Evidence Do We Have Now?
Hsu, Jason E; Horneff, John G; Gee, Albert O
2016-01-01
Recurrent tears after rotator cuff repair are common. Postoperative rehabilitation after rotator cuff repair is a modifiable factor controlled by the surgeon that can affect re-tear rates. Some surgeons prefer early mobilization after rotator cuff repair, whereas others prefer a period of immobilization to protect the repair site. The tendon-healing process incorporates biochemical and biomechanical responses to mechanical loading. Healing can be optimized with controlled loading. Complete load removal and chronic overload can be deleterious to the process. Several randomized clinical studies have also characterized the role of postoperative mobilization after rotator cuff repair. Copyright © 2016 Elsevier Inc. All rights reserved.
Amine content of vaginal fluid from untreated and treated patients with nonspecific vaginitis.
Chen, K C; Forsyth, P S; Buchanan, T M; Holmes, K K
1979-01-01
We examined the vaginal washings from patients with nonspecific vaginitis (NSV) to seek biochemical markers and possible explanations for the signs and symptoms of this syndrome. Seven amines were identified including methylamine, isobutylamine, putrescine, cadaverine, histamine, tyramine, and phenethylamine. These amines may contribute to the symptoms of NSV and may contribute to the elevated pH of the vaginal discharge. They may also be partly responsible for the "fishy" odor that is characteristic of vaginal discharges from these patients. Among the seven amines, putrescine and cadaverine were the most abundant and were present in all vaginal discharges from each of ten patients before treatment. These amines are produced in vitro during growth of mixed vaginal bacteria in chemically defined medium, presumably by decarboxylation of the corresponding amino acids. We hypothesize the anaerobic vaginal organisms, previously shown to be quantitatively increased in NSV, are responsible for the amine production, because metronidazole inhibited the production of amines by vaginal bacteria in vitro, and Haemophilus vaginalis did not produce amines. H. vaginalis did release high concentrations of pyruvic acid and of amino acids during growth in peptone-starch-dextrose medium, whereas, other vaginal flora consumed both pyruvic acid and amino acids in the same medium during growth. These findings suggest that a symbiotic relationship may exist between H. vaginalis and other vaginal flora in patients with NSV. Images PMID:447831
Kvistgaard Olsen, Jack; Fener, Dilay Kesgin; Waehrens, Eva Elisabet; Wulf Christensen, Anton; Jespersen, Anders; Danneskiold-Samsøe, Bente; Bartels, Else Marie
2017-07-01
Computerized pneumatic cuff pressure algometry (CPA) using the DoloCuff is a new method for pain assessment. Intra- and inter-rater reliabilities have not yet been established. Our aim was to examine the inter- and intrarater reliabilities of DoloCuff measures in healthy subjects. Twenty healthy subjects (ages 20 to 29 years) were assessed three times at 24-hour intervals by two trained raters. Inter-rater reliability was established based on the first and second assessments, whereas intrarater reliability was based on the second and third assessments. Subjects were randomized 1:1 to first assessment at either rater 1 or rater 2. The variables of interest were pressure pain threshold (PT), pressure pain tolerance (PTol), and temporal summation index (TSI). Reliability was estimated by a two-way mixed intraclass correlation coefficient (ICC) absolute agreement analysis. Reliability was considered excellent if ICC > 0.75, fair to good if 0.4 < ICC < 0.75, and poor if ICC < 0.4. Bias and random errors between raters and assessments were evaluated using 95% confidence interval (CI) and Bland-Altman plots. Inter-rater reliability for PT, PTol, and TSI was 0.88 (95% CI: 0.69 to 0.95), 0.86 (95% CI: 0.65 to 0.95), and 0.81 (95% CI: 0.42 to 0.94), respectively. The intrarater reliability for PT, PTol, and TSI was 0.81 (95% CI: 0.53 to 0.92), 0.89 (95% CI: 0.74 to 0.96), and 0.75 (95% CI: 0.28 to 0.91), respectively. Inter-rater reliability was excellent for PT, PTol, and TSI. Similarly, the intrarater reliability for PT and PTol was excellent, while borderline excellent/good for TSI. Therefore, the DoloCuff can be used to obtain reliable measures of pressure pain parameters in healthy subjects. © 2016 World Institute of Pain.
Endotracheal Tube Cuff Pressures in Patients Intubated Prior to Helicopter EMS Transport
Tennyson, Joseph; Ford-Webb, Tucker; Weisberg, Stacy; LeBlanc, Donald
2016-01-01
Introduction Endotracheal intubation is a common intervention in critical care patients undergoing helicopter emergency medical services (HEMS) transportation. Measurement of endotracheal tube (ETT) cuff pressures is not common practice in patients referred to our service. Animal studies have demonstrated an association between the pressure of the ETT cuff on the tracheal mucosa and decreased blood flow leading to mucosal ischemia and scarring. Cuff pressures greater than 30 cmH2O impede mucosal capillary blood flow. Multiple prior studies have recommended 30 cmH2O as the maximum safe cuff inflation pressure. This study sought to evaluate the inflation pressures in ETT cuffs of patients presenting to HEMS. Methods We enrolled a convenience sample of patients presenting to UMass Memorial LifeFlight who were intubated by the sending facility or emergency medical services (EMS) agency. Flight crews measured the ETT cuff pressures using a commercially available device. Those patients intubated by the flight crew were excluded from this analysis as the cuff was inflated with the manometer to a standardized pressure. Crews logged the results on a research form, and we analyzed the data using Microsoft Excel and an online statistical analysis tool. Results We analyzed data for 55 patients. There was a mean age of 57 years (range 18–90). The mean ETT cuff pressure was 70 (95% CI= [61–80]) cmH2O. The mean lies 40 cmH2O above the maximum accepted value of 30 cmH2O (p<0.0001). Eighty-four percent (84%) of patients encountered had pressures above the recommended maximum. The most frequently recorded pressure was >120 cmH2O, the maximum pressure on the analog gauge. Conclusion Patients presenting to HEMS after intubation by the referral agency (EMS or hospital) have ETT cuffs inflated to pressures that are, on average, more than double the recommended maximum. These patients are at risk for tracheal mucosal injury and scarring from decreased mucosal capillary blood flow
Brody, Stuart; Weiss, Petr
2010-08-01
Evidence was recently provided for vaginal orgasm, orgasm triggered purely by penile-vaginal intercourse (PVI), being associated with better psychological functioning. Common sex education and sexual medicine approaches might undermine vaginal orgasm benefits. To examine the extent to which women's vaginal orgasm consistency is associated with (i) being told in childhood or adolescence that the vagina was the important zone for inducing female orgasm; (ii) how well they focus mentally on vaginal sensations during PVI; (iii) greater PVI duration; and (iv) preference for above-average penis length. In a representative sample of the Czech population, 1,000 women reported their vaginal orgasm consistency (from never to almost every time; only 21.9% never had a vaginal orgasm), estimates of their typical foreplay and PVI durations, what they were told in childhood and adolescence was the important zone for inducing female orgasm, their degree of focus on vaginal sensations during PVI, and whether they were more likely to orgasm with a longer than average penis. The association of vaginal orgasm consistency with the predictors noted above. Vaginal orgasm consistency was associated with all hypothesized correlates. Multivariate analysis indicated the most important predictors were being educated that the vagina is important for female orgasm, being mentally focused on vaginal sensations during PVI, and in some analyses duration of PVI (but not foreplay) and preferring a longer than average penis. Focusing attention on penile-vaginal sensation supports vaginal orgasm and the myriad benefits thereof. Brody S, and Weiss P. Vaginal orgasm is associated with vaginal (not clitoral) sex education, focusing mental attention on vaginal sensations, intercourse duration, and a preference for a longer penis. © 2009 International Society for Sexual Medicine.
Acromion Index in Korean Population and Its Relationship with Rotator Cuff Tears.
Kum, Dong Ho; Kim, Jun Ho; Park, Keun Min; Lee, Eun Su; Park, Yong Bok; Yoo, Jae Chul
2017-06-01
Among the many causes of rotator cuff tears, scapular morphology is associated with the accelerating degenerative process of the rotator cuff. Acromion index (AI) was previously introduced and compared in two populations. We enrolled 100 Korean patients diagnosed with full-thickness rotator cuff tears by magnetic resonance imaging and intraoperative arthroscopic findings between January and December 2013. Another 100 Korean patients with an intact rotator cuff tendon identified on magnetic resonance imaging and other shoulder diseases, such as frozen shoulder and instability, were enrolled as controls. We retrospectively compared these 100 rotator cuff tear patients (mean age, 63 years) and 100 controls (mean age, 51 years) in this study. Two independent orthopedic surgeons assessed the AI on radiographs. We performed an interobserver reliability test of the AI assessment, and then compared the AI between two groups. The measurement of the AI showed excellent reliability (intraclass correlation coefficient, 0.82). The mean AI in the rotator cuff tear group was 0.68 and it was significantly different between groups ( p <0.001, 95% confidence interval). The AI was not related to tear size. Our study showed that the AI was an effective predictive factor for rotator cuff tears in a Korean population.
ERIC Educational Resources Information Center
Connors, G. Patrick
Many baseball players suffer from shoulder injuries related to the rotator cuff muscles. These injuries may be classified as muscular strain, tendonitis or tenosynovitis, and impingement syndrome. Treatment varies from simple rest to surgery, so it is important to be seen by a physician as soon as possible. In order to prevent these injuries, the…
[Contribution of MRI to the preoperative evaluation of rotator cuff tears].
Gagey, N; Desmoineaux, P; Gagey, O; Idy-Peretti, I; Mazas, F
1991-01-01
The authors report a series of 38 patients who had been examined by MRI and then operated for a rotator cuff syndrome. The correlation between the description of the cuff lesions after MRI and the surgical observations were excellent for 37 patients. In one case MRI showed a false image of tear of the supra spinatus m. on its anterior edge. This was due to a bad knowledge of the anatomy of the muscle and tendon and to a poor orientation of the frontal cut plane. This study was completed with MRI and anatomic study of 12 non embalmed cadaveric shoulders. The results showed that MRI was very sensitive (0.93) and specific (0.94) for the diagnosis of rotator cuff tears. MRI allowed also to show partial tears of the tendons of the rotator cuff. The authors propose a MRI classification of cuff lesions which permits to establish a good surgical planning.
... essential to determine what type of cyst or mass you may have. A mass or bulge of the vaginal wall may be ... to rule out vaginal cancer, especially if the mass appears to be solid. If the cyst is ...
Menopause and the vaginal microbiome.
Muhleisen, Alicia L; Herbst-Kralovetz, Melissa M
2016-09-01
For over a century it has been well documented that bacteria in the vagina maintain vaginal homeostasis, and that an imbalance or dysbiosis may be associated with poor reproductive and gynecologic health outcomes. Vaginal microbiota are of particular significance to postmenopausal women and may have a profound effect on vulvovaginal atrophy, vaginal dryness, sexual health and overall quality of life. As molecular-based techniques have evolved, our understanding of the diversity and complexity of this bacterial community has expanded. The objective of this review is to compare the changes that have been identified in the vaginal microbiota of menopausal women, outline alterations in the microbiome associated with specific menopausal symptoms, and define how hormone replacement therapy impacts the vaginal microbiome and menopausal symptoms; it concludes by considering the potential of probiotics to reinstate vaginal homeostasis following menopause. This review details the studies that support the role of Lactobacillus species in maintaining vaginal homeostasis and how the vaginal microbiome structure in postmenopausal women changes with decreasing levels of circulating estrogen. In addition, the associated transformations in the microanatomical features of the vaginal epithelium that can lead to vaginal symptoms associated with menopause are described. Furthermore, hormone replacement therapy directly influences the dominance of Lactobacillus in the microbiota and can resolve vaginal symptoms. Oral and vaginal probiotics hold great promise and initial studies complement the findings of previous research efforts concerning menopause and the vaginal microbiome; however, additional trials are required to determine the efficacy of bacterial therapeutics to modulate or restore vaginal homeostasis. Copyright © 2016 Elsevier Ireland Ltd. All rights reserved.
Comorbidities in rotator cuff disease: a case-control study.
Titchener, Andrew G; White, Jonathan J E; Hinchliffe, Sally R; Tambe, Amol A; Hubbard, Richard B; Clark, David I
2014-09-01
Rotator cuff disease is a common condition in the general population, but relatively little is known about its associated risk factors. We have undertaken a large case-control study using The Health Improvement Network database to assess and to quantify the relative contributions of some constitutional and environmental risk factors for rotator cuff disease in the community. Our data set included 5000 patients with rotator cuff disease who were individually matched with a single control by age, sex, and general practice (primary care practice). The median age at diagnosis was 55 years (interquartile range, 44-65 years). Multivariate analysis showed that the risk factors associated with rotator cuff disease were Achilles tendinitis (odds ratio [OR] = 1.78), trigger finger (OR = 1.99), lateral epicondylitis (OR = 1.71), and carpal tunnel syndrome (OR = 1.55). Oral corticosteroid therapy (OR = 2.03), oral antidiabetic use (OR = 1.66), insulin use (OR = 1.77), and "overweight" body mass index of 25.1 to 30 (OR = 1.15) were also significantly associated. Current or previous smoking history, body mass index of greater than 30, any alcohol intake, medial epicondylitis, de Quervain syndrome, cubital tunnel syndrome, and rheumatoid arthritis were not found to be associated with rotator cuff disease. We have identified a number of comorbidities and risk factors for rotator cuff disease. These include lateral epicondylitis, carpal tunnel syndrome, trigger finger, Achilles tendinitis, oral corticosteroid use, and diabetes mellitus. The findings should alert the clinician to comorbid pathologic processes and guide future research into the etiology of this condition. Copyright © 2014 Journal of Shoulder and Elbow Surgery Board of Trustees. Published by Mosby, Inc. All rights reserved.
Prevalence of vaginal candidiasis among pregnant women with abnormal vaginal discharge in Maiduguri.
Ibrahim, S M; Bukar, M; Mohammed, Y; Mohammed, B; Yahaya, M; Audu, B M; Ibrahim, H M; Ibrahim, H A
2013-01-01
Pregnancy represents a risk factor in the occurrence of vaginal candidiasis. To determine the prevalence and clinical features associated with abnormal vaginal discharge and C. albicans infection in pregnant women. High vaginal swab samples and data on epidemiological characteristics were collected from 400 pregnant women with complaints of abnormal vaginal discharge at booking clinic of University of Maiduguri Teaching Hospital. The data was analysed using SPSS 16.0 statistical software. The prevalence of abnormal vaginal discharge in pregnancy was 31.5%. The frequency of abnormal vaginal discharge was 183 (45.8%) among those aged 20-24 years, 291 (72.8%) in multipara, 223 (55.8%) in those with Primary education and 293 (73.2%) in unemployed. Vulval pruritus 300 (75.0%) was significantly related to abnormal vaginal discharge (P < 0.001). The prevalence of C. albicans was 41%. The frequencies of Vulval itching, Dyspareunia and vulval excoriation among those with candidiasis were 151 (50.3%), 14 (56.0%) and 75 (75.0%) respectively (P < 0.001). The prevalence of abnormal vaginal discharge in pregnancy was high in this study and C. albicans was the commonest cause. It is recommended that a pregnant woman complaining of abnormal vaginal discharge be assessed and Laboratory diagnosis done in order to give appropriate treatment.
Managing endotracheal tube cuff pressure at altitude: a comparison of four methods.
Britton, Tyler; Blakeman, Thomas C; Eggert, John; Rodriquez, Dario; Ortiz, Heather; Branson, Richard D
2014-09-01
Ascent to altitude results in the expansion of gases in closed spaces. The management of overinflation of the endotracheal tube (ETT) cuff at altitude is critical to prevent mucosal injury. We continuously measured ETT cuff pressures during a Critical Care Air Transport Team training flight to 8,000-ft cabin pressure using four methods of cuff pressure management. ETTs were placed in a tracheal model, and mechanical ventilation was performed. In the control ETT, the cuff was inflated to 20 mm Hg to 22 mm Hg and not manipulated. The manual method used a pressure manometer to adjust pressure at cruising altitude and after landing. A PressureEasy device was connected to the pilot balloon of the third tube and set to a pressure of 20 mm Hg to 22 mm Hg. The final method filled the balloon with 10 mL of saline. Both size 8.0-mm and 7.5-mm ETT were studied during three flights. In the control tube, pressure exceeded 70 mm Hg at cruising altitude. Manual management corrected for pressure at altitude but resulted in low cuff pressures upon landing (<10 mm Hg). The PressureEasy reduced the pressure change to a maximum of 36 mm Hg, but on landing, cuff pressures were less than 15 mm Hg. Saline inflation ameliorated cuff pressure changes at altitude, but initial pressures were 40 mm Hg. None of the three methods using air inflation managed to maintain cuff pressures below those associated with tracheal damage at altitude or above pressures associated with secretion aspiration during descent. Saline inflation minimizes altitude-related alteration in cuff pressure but creates excessive pressures at sea level. New techniques need to be developed.
Ricinosomes Predict Programmed Cell Death Leading to Anther Dehiscence in Tomato1[C][W][OA
Senatore, Adriano; Trobacher, Christopher P.; Greenwood, John S.
2009-01-01
Successful development and dehiscence of the anther and release of pollen are dependent upon the programmed cell death (PCD) of the tapetum and other sporophytic tissues. Ultrastructural examination of the developing and dehiscing anther of tomato (Solanum lycopersicum) revealed that cells of the interlocular septum, the connective tissue, the middle layer/endothecium, and the epidermal cells surrounding the stomium all exhibit features consistent with progression through PCD. Ricinosomes, a subset of precursor protease vesicles that are unique to some incidents of plant PCD, were also present in all of these cell types. These novel organelles are known to harbor KDEL-tailed cysteine proteinases that act in the final stages of corpse processing following cell death. Indeed, a tomato KDEL-tailed cysteine proteinase, SlCysEP, was identified and its gene was cloned, sequenced, and characterized. SlCysEP transcript and protein were restricted to the anthers of the senescing tomato flower. Present in the interlocular septum and in the epidermal cells surrounding the stomium relatively early in development, SlCysEP accumulates later in the sporophytic tissues surrounding the locules as dehiscence ensues. At the ultrastuctural level, immunogold labeling localized SlCysEP to the ricinosomes within the cells of these tissues, but not in the tapetum. It is suggested that the accumulation of SlCysEP and the appearance of ricinosomes act as very early predictors of cell death in the tomato anther. PMID:19098090
Adogwa, Owoicho; Fatemi, Parastou; Perez, Edgar; Moreno, Jessica; Gazcon, Gustavo Chagoya; Gokaslan, Ziya L; Cheng, Joseph; Gottfried, Oren; Bagley, Carlos A
2014-12-01
Wound dehiscence and surgical site infections (SSIs) can have a profound impact on patients as they often require hospital readmission, additional surgical interventions, lengthy intravenous antibiotic administration, and delayed rehabilitation. Negative pressure wound therapy (NPWT) exposes the wound site to negative pressure, resulting in the improvement of blood supply, removal of excess fluid, and stimulation of cellular proliferation of granulation tissue. To assess the incidence of wound infection and dehiscence in patients undergoing long-segment thoracolumbar fusion before and after the routine use of NPWT. Retrospective study. One hundred sixty patients undergoing long-segment thoracolumbar spine fusions were included in this study. Postoperative incidence of wound infection and dehiscence. All adult patients undergoing thoracolumbar fusion for spinal deformity over a 6-year period at Duke University Medical Center by the senior author (CB) were included in this study. In 2012, a categorical change was made by the senior author (CB) that included the postoperative routine use of incisional NPWT devices after primary wound closure in all long-segment spine fusions. Before 2012, NPWT was not used. After primary wound closure, a negative pressure device is contoured to the size of the incision and placed over the incision site for 3 postoperative days. We retrospectively review the first 46 cases in which NPWT was used and compared them with the immediately preceding 114 cases to assess the incidence of wound infection and dehiscence. One hundred sixty (NPWT: 46 cases, non-NPWT: 114 cases) long-segment thoracolumbar spine fusions were performed for deformity correction. Baseline characteristics were similar between both cohorts. Compared with the non-NPWT cohort, a 50% decrease in the incidence of wound dehiscence was observed in the NPWT patient cohort (6.38% vs. 12.28%, p=.02). Similarly, compared with the non-NPWT cohort, the incidence of postoperative
Genome-wide association study identifies a locus associated with rotator cuff injury
Roos, Thomas R.; Roos, Andrew K.; Avins, Andrew L.; Ahmed, Marwa A.; Kleimeyer, John P.; Fredericson, Michael; Ioannidis, John P. A.; Dragoo, Jason L.
2017-01-01
Rotator cuff tears are common, especially in the fifth and sixth decades of life, but can also occur in the competitive athlete. Genetic differences may contribute to overall injury risk. Identifying genetic loci associated with rotator cuff injury could shed light on the etiology of this injury. We performed a genome-wide association screen using publically available data from the Research Program in Genes, Environment and Health including 8,357 cases of rotator cuff injury and 94,622 controls. We found rs71404070 to show a genome-wide significant association with rotator cuff injury with p = 2.31x10-8 and an odds ratio of 1.25 per allele. This SNP is located next to cadherin8, which encodes a protein involved in cell adhesion. We also attempted to validate previous gene association studies that had reported a total of 18 SNPs showing a significant association with rotator cuff injury. However, none of the 18 SNPs were validated in our dataset. rs71404070 may be informative in explaining why some individuals are more susceptible to rotator cuff injury than others. PMID:29228018
Perivascular fluid cuffs decrease lung compliance by increasing tissue resistance.
Lowe, Kevin; Alvarez, Diego F; King, Judy A; Stevens, Troy
2010-06-01
Lung inflammation causes perivascular fluid cuffs to form around extra-alveolar blood vessels; however, the physiologic consequences of such cuffs remain poorly understood. Herein, we tested the hypothesis that perivascular fluid cuffs, without concomitant alveolar edema, are sufficient to decrease lung compliance. Prospective, randomized, controlled study. Research laboratory. One hundred twenty male CD40 rats. To test this hypothesis, the plant alkaloid thapsigargin was used to activate store-operated calcium entry and increase cytosolic calcium in endothelium. Thapsigargin was infused into a central venous catheter of intact, sedated, and mechanically ventilated rats. Static and dynamic lung mechanics and hemodynamics were measured continuously. Thapsigargin produced perivascular fluid cuffs along extra-alveolar vessels but did not cause alveolar flooding or blood gas abnormalities. Lung compliance dose-dependently decreased after thapsigargin infusion, attributable to an increase in tissue resistance that was attributed to increased tissue damping and tissue elastance. Airway resistance was not changed. Neither central venous pressure nor left ventricular end diastolic pressure was altered by thapsigargin. Heart rate did not change, although thapsigargin decreased left ventricular systolic function sufficient to reduce cardiac output by 50%. Infusion of the type 4 phosphodiesterase inhibitor, rolipram, prevented thapsigargin from inducing perivascular cuffs and decreasing lung compliance. Rolipram also normalized pressure over time and corrected the deficit in cardiac output. Our findings resolve for the first time that perivascular cuff formation negatively impacts mechanical coupling between the bronchovascular bundle and the lung parenchyma, decreasing lung compliance without impacting central venous pressure.
Gene expression profiles of changes underlying different-sized human rotator cuff tendon tears.
Chaudhury, Salma; Xia, Zhidao; Thakkar, Dipti; Hakimi, Osnat; Carr, Andrew J
2016-10-01
Progressive cellular and extracellular matrix (ECM) changes related to age and disease severity have been demonstrated in rotator cuff tendon tears. Larger rotator cuff tears demonstrate structural abnormalities that potentially adversely influence healing potential. This study aimed to gain greater insight into the relationship of pathologic changes to tear size by analyzing gene expression profiles from normal rotator cuff tendons, small rotator cuff tears, and large rotator cuff tears. We analyzed gene expression profiles of 28 human rotator cuff tendons using microarrays representing the entire genome; 11 large and 5 small torn rotator cuff tendon specimens were obtained intraoperatively from tear edges, which we compared with 12 age-matched normal controls. We performed real-time polymerase chain reaction and immunohistochemistry for validation. Torn rotator cuff tendons demonstrated upregulation of a number of key genes, such as matrix metalloproteinase 3, 10, 12, 13, 15, 21, and 25; a disintegrin and metalloproteinase (ADAM) 12, 15, and 22; and aggrecan. Amyloid was downregulated in all tears. Small tears displayed upregulation of bone morphogenetic protein 5. Chemokines and cytokines that may play a role in chemotaxis were altered; interleukins 3, 10, 13, and 15 were upregulated in tears, whereas interleukins 1, 8, 11, 18, and 27 were downregulated. The gene expression profiles of normal controls and small and large rotator cuff tear groups differ significantly. Extracellular matrix remodeling genes were found to contribute to rotator cuff tear pathogenesis. Rotator cuff tears displayed upregulation of a number of matrix metalloproteinase (3, 10, 12, 13, 15, 21, and 25), a disintegrin and metalloproteinase (ADAM 12, 15, and 22) genes, and downregulation of some interleukins (1, 8, and 27), which play important roles in chemotaxis. These gene products may potentially have a role as biomarkers of failure of healing or therapeutic targets to improve tendon
Leakage of fluid around endotracheal tube cuffs: a cadaver study
Lucius, Ralph; Ewald, Kristian
2013-01-01
Background The aim of the study was to evaluate the leakage of liquid past the cuffs of tracheal tubes in fresh frozen human heads. Methods Six truncated fresh frozen heads were used and intubated with 8.0 mm endotracheal tubes. The intracuff pressures tested were 30 and 100 cmH2O. Subsequently, 20 ml of each of two oral antiseptic rinses (0.2% chlorhexidine and octenidine [octenidol®, Schülke & Mayr GmbH, Norderstedt, Germany]) was applied for thirty seconds in the mouth. During the trial, leakage of the cuffs was examined. Results The sealing between the tracheal cuff and tracheal wall was leakage-proof for all tested intracuff pressures and all tested antiseptic rinses. However, approximately 5.6 ml and 1.8 ml leaked into the esophagus and remained as a cuff-puddle, respectively. Conclusions The sealing between an endotracheal tube cuff with an intracuff pressure of 30 cmH2O and the tracheal wall is leakage-proof during oral care with antiseptic rinsing. An increase of intracuff pressure to 100 cmH2O does not appear to be required. PMID:24363847
Editorial Commentary: Subacromial Decompression Is Unnecessary in Most Routine Rotator Cuff Repairs.
Solomon, Daniel J
2017-07-01
There is no need to perform subacromial decompression in partial bursal-sided rotator cuff repairs to obtain a good result. This, paired with the findings of previous studies of full-thickness rotator cuff repairs, suggests that extrinsic factors rarely affect the rotator cuff. Copyright © 2017 Arthroscopy Association of North America. Published by Elsevier Inc. All rights reserved.
The development of confocal arthroscopy as optical histology for rotator cuff tendinopathy.
Wu, J-P; Walton, M; Wang, A; Anderson, P; Wang, T; Kirk, T B; Zheng, M H
2015-09-01
MRI, ultrasound and video arthroscopy are traditional imaging technologies for noninvasive or minimal invasive assessment of the rotator cuff tendon pathology. However, these imaging modalities do not have sufficient resolution to demonstrate the pathology of rotator cuff tendons at a microstructural level. Therefore, they are insensitive to low-level tendon diseases. Although traditional histology can be used to analyze the physiology of rotator cuff tendons, it requires biopsy that traumatizes the rotator cuff, thus, potentially comprising the mechanical properties of tendons. Besides, it cannot offer real-time histological information. Confocal endoscopy offers a way to assess the microstructural disorder in tissues without biopsy. However, the application of this useful technique for detecting low-level tendon diseases has been restricted by using clinical grade fluorescent contrast agent to acquire high-resolution microstructural images of tendons. In this study, using a clinical grade sodium fluorescein contrast agent, we have reported the development of confocal arthroscopy for optical histological assessment without biopsy. The confocal arthroscopic technique was able to demonstrate rotator cuff tendinopathy in human cadavers, which appeared macroscopically normal under video arthroscopic examinations. The tendinopathy status of the rotator cuff tendons was confirmed by corresponding traditional histology. The development of confocal arthroscopy may provide a minimally invasive imaging technique for real-time histology of rotator cuff without the need for tissue biopsy. This technique has the potential for surgeons to gain in real time the histological information of rotator cuff tendons, which may assist planning repair strategies and potentially improve intervention outcomes. © 2015 The Authors Journal of Microscopy © 2015 Royal Microscopical Society.
Vaginal fistula Overview A vaginal fistula is an abnormal opening that connects your vagina to another organ, such as your bladder, colon or rectum. Your ... describe the condition as a hole in your vagina that allows stool or urine to pass through ...
Teratani, Takeshi
2017-12-01
The purpose of this study was to investigate the prevalence, epidemiology, and outcomes of anterosuperior (A group) rotator cuff tears (RCTs) and posterosuperior (P group) RCTs treated by arthroscopic rotator cuff repair (ARCR). A total of 67 A group patients and 14 P group patients were included in the study. The prevalence of the A group (82.3%) was significantly higher than that of the P group (17.7%). The outcomes in both groups were good, even though the A group had a higher rate of injury to the LHB than the P group. Level III, case-control Study, treatment study.
Seyyedi, Fatemeh; Kopaei, Mahmoud Rafiean; Miraj, Sepideh
2016-11-01
This study was conducted to evaluate the therapeutic effects of vaginal royal jelly and vaginal estrogen on quality of life and vaginal atrophy in postmenopausal women. This double-blind randomized controlled clinical trial was carried out at gynecology and obstetrics clinics of Hajar Hospital of Shahrekord University of Medical Sciences (Iran) from January 2013 to January 2014. The study was conducted on married postmenopausal women between 50 and 65 years old. Of 120 patients, 30 individuals were excluded based on the exclusion criteria, and 90 women were randomly distributed into three groups of 30 royal jelly vaginal cream 15%, vaginal Premarin, and placebo (lubricant), for three months. At the beginning and the end of the study, quality of life and vaginal cytology assay were evaluated. Data were analyzed by SPSS Version 11. Vaginal cream of royal jelly is significantly more effective than vaginal cream of Premarin and lubricant in improvement of quality of life in postmenopausal women (p<0.05). Moreover, Pap smear results showed that vaginal atrophy in vaginal Premarin group was lower than the other groups (p<0.001), and there was no significant difference between lubricant and royal jelly groups (p=0.89). Administration of vaginal royal jelly was effective in quality-of-life improvement of postmenopausal women. Given to the various properties of royal jelly and its effectiveness on quality of life and vaginal atrophy in postmenopausal women, further studies are recommended for using =royal jelly in improving menopausal symptoms. The trial was registered at the Iranian Registry of Clinical Trials (http://www.irct.ir) with the IRCT code: 2014112220043n1. Shahrekord University of Medical Sciences supported this research (project no. 1440).
Walter, S G; Stadler, T; Thomas, T S; Thomas, W
2018-03-02
To introduce a (semi-)quantitative surgical score for the classification of rotator cuff tears. A total of 146 consecutive patients underwent rotator cuff repair and were assessed using the previously defined Advanced Rotator Cuff Tear Score (ARoCuS) criteria: muscle tendon, size, tissue quality, pattern as well as mobilization of the tear. The data set was split into a training (125 patients) and a testing set (21 patients). The training data set fitted a nonlinear predictive model of the tear score based on the ARoCuS criteria, while the testing data served as control. Based on the scoring results, rotator cuff tears were assigned to one of four categories (ΔV I-IV) and received a stage-adapted treatment. For statistical analysis, mean values ± standard deviation, interclass correlation coefficients (ICC) and kappa values were calculated. Overall, 32 patients were classified as ΔV I, 68 as ΔV II and 37 as ΔV III. Nine patients showed ΔV IV tears. Patients of all ΔV groups improved significantly their Constant scores (p < 0.001) and profited from significant pain reduction after surgery (p < 0.001). To date, ten patients have undergone revision surgery with five of them primarily classified as ΔV IV. Kappa values for the interobserver reliability ranged between 0.69 and 0.95. ICC scores for the ΔV category were 0.95 for interobserver reliability. The ARoCuS facilitates intra-operative decision-making and enables surgeons and researches to document rotator cuff tears in a standardized and reproducible manner.
From the RSNA refresher courses: US of the rotator cuff: pitfalls, limitations, and artifacts.
Rutten, Matthieu J C M; Jager, Gerrit J; Blickman, Johan G
2006-01-01
High-resolution ultrasonography (US) has gained increasing popularity as a diagnostic tool for assessment of the soft tissues in shoulder impingement syndrome. US is a powerful and accurate method for diagnosis of rotator cuff tears and other rotator cuff abnormalities, provided the examiner has a detailed knowledge of shoulder anatomy, uses a standardized examination technique, and has a thorough understanding of the potential pitfalls, limitations, and artifacts. False-positive sonographic findings of rotator cuff tears can be caused by the technique (anisotropy, transducer positioning, acoustic shadowing by the deltoid septum), by the anatomy (rotator cuff interval, supraspinatus-infraspinatus interface, musculotendinous junction, fibrocartilaginous insertion), or by disease (criteria for diagnosis of rotator cuff tears, tendon inhomogeneity, acoustic shadowing by scar tissue or calcification, rotator cuff thinning). False-negative sonographic findings of rotator cuff tears can be caused by the technique (transducer frequency, suboptimal focusing, imaging protocol, transducer handling), by the anatomy (nondiastasis of the ruptured tendon fibers, posttraumatic obscuration of landmarks), by disease (tendinosis, calcifications, synovial proliferation, granulation or scar tissue, bursal thickening, massive rotator cuff tears), or by patient factors (obesity, muscularity, limited shoulder motion). (c) RSNA, 2006.
Vaginal lactobacilli profile in pregnant women with normal & abnormal vaginal flora.
Yeruva, Thirupathaiah; Rajkumar, Hemalatha; Donugama, Vasundhara
2017-10-01
Lactobacilli species that are better adapted to vaginal environment of women may colonize better and offer protection against vaginal pathogenic bacteria. In this study, the distribution of common Lactobacillus species was investigated in pregnant women. Sixty seven pregnant women were included in the study and vaginal samples were collected for Gram staining. Women were classified as normal vaginal flora, intermediate flora and bacterial vaginosis (BV) based on Nugent's score. Vaginal samples were also collected for the identification of Lactobacillus spp. by multiplex polymerase chain reaction (PCR) profiling of 16S rDNA amplification method. Lactobacillus crispatus (100%) was the most predominant Lactobacillus spp. present in pregnant women with normal flora, followed by L. iners (77%), L. jensenii (74%) and L. helveticus (60%). While, L. iners was commonly present across groups in women with normal, intermediate or BV flora, L. crispatus, L. jensenii and L. helveticus decreased significantly as the vaginal flora changed to intermediate and BV. In women with BV, except L. iners other species of lactobacilli was less frequently prevalent. Species such as L. rhamnosus, L. fermentum, L. paracasei and L. casei were not detected in any vaginal sample. L. crispatus, L. jensinii and L. helveticus were predominant species in women with normal flora. L. crispatus alone or in combination with L. jensinii and L. helveticus may be evaluated for probiotic properties for the prevention and treatment of BV.
Liang, Fuyou; Takagi, Shu; Himeno, Ryutaro; Liu, Hao
2013-01-01
A variety of methods have been proposed to noninvasively assess arterial stiffness using single or multiple oscillometric cuffs. A common pitfall of most of such methods is that the individual-specific accuracy of assessment is not clearly known due to an insufficient understanding of the relationships between the characteristics of cuff oscillometry and cardiovascular properties. To provide a tool for quantitatively investigating such relationships, we developed a computational model of the cardiovascular system coupled with an oscillometric cuff wrapped around the left upper arm. The model was first examined by simulating the inflation-deflation process of the cuff. The simulated results reasonably reproduced the well-established characteristics of cuff oscillometry. The model was then applied to study the oscillation wave generated by a suprasystolic cuff that is currently under considerable debate regarding its validity for assessing aortic stiffness. The simulated results confirmed the experimental observations that the suprasystolic cuff oscillation wave resembles the blood pressure wave in the proximal brachial artery and is characterised by the presence of two systolic peaks. A systemic analysis on the simulation results for various cardiovascular/physiological conditions revealed that neither the time lag nor the height difference between the two peaks is a direct indicator of aortic stiffness. These findings provided useful evidence for explaining the conflicts among previous studies. Finally, it was stressed that although the emphasis of this study has been placed on a suprasystolic upper-arm cuff, the model could be employed to address more issues related to oscillometric cuffs.
Vaginal biogenic amines: biomarkers of bacterial vaginosis or precursors to vaginal dysbiosis?
Nelson, Tiffanie M.; Borgogna, Joanna-Lynn C.; Brotman, Rebecca M.; Ravel, Jacques; Walk, Seth T.; Yeoman, Carl J.
2015-01-01
Bacterial vaginosis (BV) is the most common vaginal disorder among reproductive age women. One clinical indicator of BV is a “fishy” odor. This odor has been associated with increases in several biogenic amines (BAs) that may serve as important biomarkers. Within the vagina, BA production has been linked to various vaginal taxa, yet their genetic capability to synthesize BAs is unknown. Using a bioinformatics approach, we show that relatively few vaginal taxa are predicted to be capable of producing BAs. Many of these taxa (Dialister, Prevotella, Parvimonas, Megasphaera, Peptostreptococcus, and Veillonella spp.) are more abundant in the vaginal microbial community state type (CST) IV, which is depleted in lactobacilli. Several of the major Lactobacillus species (L. crispatus, L. jensenii, and L. gasseri) were identified as possessing gene sequences for proteins predicted to be capable of putrescine production. Finally, we show in a small cross sectional study of 37 women that the BAs putrescine, cadaverine and tyramine are significantly higher in CST IV over CSTs I and III. These data support the hypothesis that BA production is conducted by few vaginal taxa and may be important to the outgrowth of BV-associated (vaginal dysbiosis) vaginal bacteria. PMID:26483694
Vaginal biogenic amines: biomarkers of bacterial vaginosis or precursors to vaginal dysbiosis?
Nelson, Tiffanie M; Borgogna, Joanna-Lynn C; Brotman, Rebecca M; Ravel, Jacques; Walk, Seth T; Yeoman, Carl J
2015-01-01
Bacterial vaginosis (BV) is the most common vaginal disorder among reproductive age women. One clinical indicator of BV is a "fishy" odor. This odor has been associated with increases in several biogenic amines (BAs) that may serve as important biomarkers. Within the vagina, BA production has been linked to various vaginal taxa, yet their genetic capability to synthesize BAs is unknown. Using a bioinformatics approach, we show that relatively few vaginal taxa are predicted to be capable of producing BAs. Many of these taxa (Dialister, Prevotella, Parvimonas, Megasphaera, Peptostreptococcus, and Veillonella spp.) are more abundant in the vaginal microbial community state type (CST) IV, which is depleted in lactobacilli. Several of the major Lactobacillus species (L. crispatus, L. jensenii, and L. gasseri) were identified as possessing gene sequences for proteins predicted to be capable of putrescine production. Finally, we show in a small cross sectional study of 37 women that the BAs putrescine, cadaverine and tyramine are significantly higher in CST IV over CSTs I and III. These data support the hypothesis that BA production is conducted by few vaginal taxa and may be important to the outgrowth of BV-associated (vaginal dysbiosis) vaginal bacteria.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Patel, Mehul K.; Cote, Michele L.; Ali-Fehmi, Rouba
2012-05-01
Purpose: The optimal adjuvant radiation treatment for endometrial carcinoma (EC) remains controversial. Adjuvant vaginal cuff brachytherapy (VB) has emerged as an increasingly common treatment modality. However, the time trends for using VB, external beam radiation therapy (EBRT), or combined therapy (VB+EBRT) have not been well characterized. We therefore examined the utilization trends of VB, EBRT, and VB+EBRT for adjuvant RT in International Federation of Gynecologic Oncology (FIGO) stage I and II EC over time. Methods and Materials: We evaluated treatment patterns for 48,122 patients with EC diagnosed between January 1995 and December 2005, using the National Cancer Institute's Surveillance, Epidemiology,more » and End Results (SEER) public use database. Chi-squared tests were used to assess differences by radiation type (VB, EBRT, and VB+EBRT) and various demographic and clinical variables. Results: Analyses were limited to 9,815 patients (20.4%) with EC who met the inclusion criteria. Among women who received adjuvant RT, the proportion receiving VB increased yearly (12.9% in 1995 compared to 32.8% in 2005 (p < 0.0001). The increasing use of VB was proportional to the decreasing use of EBRT (56.1% in 1995 to 45.8% in 2005; p < 0.0001) and VB+EBRT (31.0% in 1995 to 21.4% in 2005; p < 0.001). Conclusions: This population-based report demonstrates an increasing trend in the use of VB in the adjuvant setting after hysterectomy for treatment of women with FIGO stage I-II EC. VB alone appears to be replacing pelvic EBRT and VB+EBRT therapy in the management of stage I-II EC.« less
Brand, Jefferson C
2016-03-01
In "Risk Factors for Infection After Rotator Cuff Repair," B. G. Vopat et al. report a lower rate of postoperative infection with an arthroscopic rotator cuff repair than with an open or mini-open approach. Although there were only 14 infections (infection rate of 0.77%), the reason for the preponderance of male patients, 13 of the 14 infections, needs further research to determine effective preventive strategies. Copyright © 2016 Arthroscopy Association of North America. Published by Elsevier Inc. All rights reserved.
Pregnancy - vaginal bleeding; Maternal blood loss - vaginal ... Up to 1 in 4 women have vaginal bleeding at some time during their pregnancy. Bleeding is more common in the first 3 months (first trimester), especially with twins.
User-independent assessment of conditioning pain modulation by cuff pressure algometry.
Graven-Nielsen, T; Izumi, M; Petersen, K K; Arendt-Nielsen, L
2017-03-01
The use of conditioning pain modulation (CPM) is hampered by poor reproducibility and lack of user-independent paradigms. This study refined the CPM paradigm by applying user-independent cuff algometry. In 20 subjects, the CPM effect of conditioning with cuff stimulation on the arm was investigated by pain test stimuli on the contralateral leg before and in parallel with different cuff conditionings (10, 30, 60 kPa/60 s; 30, 60 kPa/10 s). As test stimulus, another cuff was inflated (1 kPa/s) until the subjects detected the pain tolerance threshold (PTT) during which the pain detection threshold (PDT) and the pressure at a pain intensity of 6 cm on a 10-cm visual analogue scale (PVAS6) were extracted. For comparison, pressure pain thresholds (PPTs) as test stimuli were recorded by the user-dependent handheld pressure algometry. Combinations of cuff locations for conditioning (pain intensity standardized) and contralateral test stimuli were additionally evaluated (leg-arm, leg-leg, arm-thigh). The test-retest reliability in two sessions 1 month apart was assessed in five CPM protocols. In all protocols, the PDT, PVAS6 and PTT increased during conditioning compared with baseline (p < 0.05). The CPM effect (i.e. conditioning minus baseline) for PVAS6, PTT and PPT increased for increasing conditioning intensities (p < 0.05). The CPM effects were not significantly different for changes in conditioning durations or conditioning/test stimulus locations. In two sessions, the CPM effects for PVAS6 and PTT assessed after 60 s of conditioning on the leg/thigh showed the highest intra-class correlations (0.47-0.73), where they were 0.04-0.6 for PPTs. The user-independent cuff algometry is reliable for CPM assessment and for supra-pain threshold test stimuli better than the user-dependent technology. A user-independent CPM technique where the conditioning is controlled by one cuff stimulation, and the test-stimulus is provided by another cuff stimulation. This study
Arthroscopic rotator cuff repair in the weight-bearing shoulder.
Kerr, Jacek; Borbas, Paul; Meyer, Dominik C; Gerber, Christian; Buitrago Téllez, Carlos; Wieser, Karl
2015-12-01
In wheelchair-dependent individuals, pain often develops because of rotator cuff tendon failure and/or osteoarthritis of the glenohumeral joint. The purposes of this study were to investigate (1) specific rotator cuff tear patterns, (2) structural healing, and (3) clinical outcomes after arthroscopic rotator cuff repair in a cohort of wheelchair-dependent patients. Forty-six shoulders with a mean follow-up of 46 months (range, 24-82 months; SD, 13 months) from a consecutive series of 61 shoulders in 56 patients (46 men and 10 women) undergoing arthroscopic rotator cuff repair were available for analysis. Clinical outcome analysis was performed using the Constant-Murley score, the Subjective Shoulder Value, and the American Shoulder and Elbow Surgeons score. The integrity of the repair was analyzed by ultrasound. Of the shoulders, 87% had supraspinatus involvement, 70% had subscapularis involvement, and 57% had an anterosuperior lesion involving both the supraspinatus and subscapularis. Despite an overall structural failure rate of 33%, the patients showed improvements in the Constant-Murley score from 50 points (range, 22-86 points; SD, 16 points) preoperatively to 80 points (range, 40-98 points; SD, 12 points) postoperatively and in the American Shoulder and Elbow Surgeons score from 56 points (range, 20-92 points; SD, 20 points) preoperatively to 92 points (range, 53-100 points; SD, 10 points) postoperatively, with a mean postoperative Subjective Shoulder Value of 84% (range, 25%-100%; SD, 17%). Failure of the rotator cuff in weight-bearing shoulders occurs primarily anterosuperiorly. Arthroscopic rotator cuff repair leads to a structural failure rate of 33% but satisfactory functional results with high patient satisfaction at midterm follow-up. Copyright © 2015 Journal of Shoulder and Elbow Surgery Board of Trustees. Published by Elsevier Inc. All rights reserved.
Li, X-X; Wang, H; Gituru, R W; Guo, Y-H; Yang, C-F
2014-01-01
Pollen presentation theory (PPT) predicts that plant species typically pollinated by frequent and wasteful pollinators ought to be much more parsimonious and only gradually release pollen compared to plant species pollinated by infrequent pollinators that are efficient at delivering the pollen they remove. To test PPT, we compare the pollen presentation schedules and pollination systems in three related Epimedium species, having different pollinators. Results showed that differences in anther dehiscence and flowering traits resulted in different pollen packaging schedules. For E. sutchuenense and E. franchetii, a special 'roll-up' movement of the anther wall during anther dehiscence increased pollen removal compared to the dehiscence pattern in E. mikinorii, which lacked the 'roll-up' movement. Investigations revealed that honeybees had a higher pollen removal rate and lower stigmatic pollen load compared to bumblebees. In accordance with PPT, E. sutchuenense presents pollen sequentially and slowly for the frequent and wasteful honeybees. In comparison to E. sutchuenense, E. franchetii had a faster presentation rate and was adapted to the efficient and infrequent bumblebees. However, E. mikinorii was pollinated by both bumblebees and honeybees at high frequency and had the fastest pollen presentation. This pattern could reduce pollen wastage by honeybees and might be an adaptation to its short flower longevity (less than 1 day), to increase the chances of pollen deposition on stigmas. The study indicates that pollen presentation schedules can be a consequence of interactions among anther dehiscence, flowering traits and pollination environments for a given species. © 2013 German Botanical Society and The Royal Botanical Society of the Netherlands.
Vaginitis: diagnosis and management.
Faro, S
1996-01-01
The various conditions that give rise to vaginitis include specific and nonspecific entities, such as candidiasis, trichomoniasis, bacterial vaginosis, group B streptococcal vaginitis, purulent vaginitis, volvodynia, and vestibulitis. The patient with chronic vaginitis usually develops this condition because of a misdiagnosis. It is critical that patients who have chronic vaginitis be thoroughly evaluated to determine if there is a specific etiology and whether their condition is recurrent or persistent, or is a reinfection. This also must include obtaining a detailed history, beginning with the patient's best recollection of when she felt perfectly normal. The physician must have an understanding of a healthy vaginal ecosystem and what mechanisms are in place to maintain the equilibrium. The vaginal ecosystem is a complex system of micro-organisms interacting with host factors to maintain its equilibrium. The endogenous microflora consists of a variety of bacteria, which include aerobic, facultative and obligate anaerobic bacteria. These organisms exist in a commensal, synergistic or antagonistic relationship. Therefore, it is important to understand what factors control the delicate equilibrium of the vaginal ecosystem, and which factors, both endogenous and exogenous, can disrupt this system. It is also important for the physician to understand that when a patient has symptoms of vaginitis it is not always due to an infectious etiology. There are situations in which an inflammatory reaction occurs but the specific etiology may not be determined. Thus, it is important that the physician not rush through the history or the examination.
Seyyedi, Fatemeh; Kopaei, Mahmoud Rafiean; Miraj, Sepideh
2016-01-01
Objective This study was conducted to evaluate the therapeutic effects of vaginal royal jelly and vaginal estrogen on quality of life and vaginal atrophy in postmenopausal women. Methods This double-blind randomized controlled clinical trial was carried out at gynecology and obstetrics clinics of Hajar Hospital of Shahrekord University of Medical Sciences (Iran) from January 2013 to January 2014. The study was conducted on married postmenopausal women between 50 and 65 years old. Of 120 patients, 30 individuals were excluded based on the exclusion criteria, and 90 women were randomly distributed into three groups of 30 royal jelly vaginal cream 15%, vaginal Premarin, and placebo (lubricant), for three months. At the beginning and the end of the study, quality of life and vaginal cytology assay were evaluated. Data were analyzed by SPSS Version 11. Results Vaginal cream of royal jelly is significantly more effective than vaginal cream of Premarin and lubricant in improvement of quality of life in postmenopausal women (p<0.05). Moreover, Pap smear results showed that vaginal atrophy in vaginal Premarin group was lower than the other groups (p<0.001), and there was no significant difference between lubricant and royal jelly groups (p=0.89). Conclusion Administration of vaginal royal jelly was effective in quality-of-life improvement of postmenopausal women. Given to the various properties of royal jelly and its effectiveness on quality of life and vaginal atrophy in postmenopausal women, further studies are recommended for using =royal jelly in improving menopausal symptoms. Clinical trial registration The trial was registered at the Iranian Registry of Clinical Trials (http://www.irct.ir) with the IRCT code: 2014112220043n1. Funding Shahrekord University of Medical Sciences supported this research (project no. 1440). PMID:28070251
Accuracy and reliability of wrist-cuff devices for self-measurement of blood pressure.
Kikuya, Masahiro; Chonan, Kenichi; Imai, Yutaka; Goto, Eiji; Ishii, Masao
2002-04-01
Self-measurement of blood pressure (BP) might offer some advantages in diagnosis and therapeutic evaluation and in patient management of hypertension. Recently, wrist-cuff devices for self-measurement of BP have gained more than one-third of the world market share. In the present study, we validated wrist-cuff devices and compared the results between wrist- and arm-cuff devices. The factors affecting the accuracy of wrist-cuff devices were also studied. The research group to assess the validity of automated blood pressure measuring device consisted of 13 institutes in Japan, which validated two wrist-cuff devices (WC-1 and WC-2) and two arm-cuff devices (AC-1 and AC-2). They used a crossover method, where the comparison was done between auscultation, by two observers by means of a double stethoscope on one arm and the device on the opposite arm or wrist. There was good inter-observer agreement for the auscultation method in each institute (systolic blood pressure (SBP), -0.1 +/- 2.8 mmHg; diastolic blood pressure (DBP), -0.1 +/- 2.6 mmHg, n = 498). The mean difference between auscultation and the device was minimal both in arm-cuff devices (mean difference for AC-1, 2.2/1.9 mmHg, n = 97 and for AC-2, 5.1/2.9 mmHg, n = 136, SBP/DBP) and wrist-cuff devices (mean difference for WC-1, -2.1/1.2 mmHg, n = 173 mmHg and for WC-2, -2.3/-5.6 mmHg, n = 92). The standard deviation of the difference (SDD) in wrist-cuff devices, however (SDD for WC-1, 9.7/7.3 mmHg and for WC-2, 10.2/8.6 mmHg), was larger than that of the arm-cuff devices (SDD for AC-1, 5.6/6.6 mmHg and for AC-2, 6.3/5.1 mmHg). Grading of AC-1 and AC-2 based on criteria of British Hypertension Society was A/A and B/A, respectively, while that of WC-1 and WC-2 was C/B and D/B, respectively. Using the same validation protocol, the results of validation for one device were divergent in each institute. In wrist-cuff devices, the BP value obtained in palmar flexion was significantly higher and that obtained in palmar
Vaginal Cancer—Health Professional Version
Vaginal cancer is often squamous cell carcinoma. Other types of vaginal cancer are adenocarcinoma, melanoma, and sarcoma. Infection with certain types of human papillomavirus (HPV) causes most vaginal cancer. Find evidence-based information on vaginal cancer treatment and research.
Vaginal drug distribution modeling.
Katz, David F; Yuan, Andrew; Gao, Yajing
2015-09-15
This review presents and applies fundamental mass transport theory describing the diffusion and convection driven mass transport of drugs to the vaginal environment. It considers sources of variability in the predictions of the models. It illustrates use of model predictions of microbicide drug concentration distribution (pharmacokinetics) to gain insights about drug effectiveness in preventing HIV infection (pharmacodynamics). The modeling compares vaginal drug distributions after different gel dosage regimens, and it evaluates consequences of changes in gel viscosity due to aging. It compares vaginal mucosal concentration distributions of drugs delivered by gels vs. intravaginal rings. Finally, the modeling approach is used to compare vaginal drug distributions across species with differing vaginal dimensions. Deterministic models of drug mass transport into and throughout the vaginal environment can provide critical insights about the mechanisms and determinants of such transport. This knowledge, and the methodology that obtains it, can be applied and translated to multiple applications, involving the scientific underpinnings of vaginal drug distribution and the performance evaluation and design of products, and their dosage regimens, that achieve it. Copyright © 2015 Elsevier B.V. All rights reserved.
Defining normal apical vaginal support: a relook at the POSST study.
Patnam, Radhika; Edenfield, Autumn; Swift, Steven
2018-06-16
The purpose of this study is to reanalyze data from the original 2005 Pelvic Organ Support Study (POSST) data set to define normal values for apical Pelvic Organ Prolapse Quantification (POP-Q) points C and D and total vaginal length (TVL) in an asymptomatic population of women. In this retrospective observational data-set review, patient were >18 years presenting for annual gynecologic exams to six centers in the United States. Data included demographics, questions about prolapse symptoms, and POP-Q points. Means and standard deviations were determined for each POP-Q point in the total population. The data set comprised 1011 women; 59 were excluded because they met criteria for having POP or were missing data. This left 948 for study. Mean age of our study population was 42 ± 14 years, and 45.6% were white, 25.1% black, and 25.2% Hispanic. One hundred fifty-six had a prior hysterectomy. Mean values with standard deviations (SD) for POP-Q values are as following: point C (vaginal cuff) -7.3 ± 1.5 cm, point C (cervix) -5.9 ± 1.5, point D -8.7 cm ± 1.5 cm, TVL (no hysterectomy) 9.8 cm ± 1.3 cm, and TVL (hysterectomy) 8.9 cm ± 1.5 cm. This data suggests normal values for POP-Q apical points in a population of patient with annual gynecological exams.
Dyrna, Felix; Kumar, Neil S; Obopilwe, Elifho; Scheiderer, Bastian; Comer, Brendan; Nowak, Michael; Romeo, Anthony A; Mazzocca, Augustus D; Beitzel, Knut
2018-05-01
Previous biomechanical studies regarding deltoid function during glenohumeral abduction have primarily used static testing protocols. (1) Deltoid forces required for scapular plane abduction increase as simulated rotator cuff tears become larger, and (2) maximal abduction decreases despite increased deltoid forces. Controlled laboratory study. Twelve fresh-frozen cadaveric shoulders with a mean age of 67 years (range, 64-74 years) were used. The supraspinatus and anterior, middle, and posterior deltoid tendons were attached to individual shoulder simulator actuators. Deltoid forces and maximum abduction were recorded for the following tear patterns: intact, isolated subscapularis (SSC), isolated supraspinatus (SSP), anterosuperior (SSP + SSC), posterosuperior (infraspinatus [ISP] + SSP), and massive (SSC + SSP + ISP). Optical triads tracked 3-dimensional motion during dynamic testing. Fluoroscopy and computed tomography were used to measure critical shoulder angle, acromial index, and superior humeral head migration with massive tears. Mean values for maximum glenohumeral abduction and deltoid forces were determined. Linear mixed-effects regression examined changes in motion and forces over time. Pearson product-moment correlation coefficients ( r) among deltoid forces, critical shoulder angles, and acromial indices were calculated. Shoulders with an intact cuff required 193.8 N (95% CI, 125.5 to 262.1) total deltoid force to achieve 79.8° (95% CI, 66.4° to 93.2°) of maximum glenohumeral abduction. Compared with native shoulders, abduction decreased after simulated SSP (-27.2%; 95% CI, -43.3% to -11.1%, P = .04), anterosuperior (-51.5%; 95% CI, -70.2% to -32.8%, P < .01), and massive (-48.4%; 95% CI, -65.2% to -31.5%, P < .01) cuff tears. Increased total deltoid forces were required for simulated anterosuperior (+108.1%; 95% CI, 68.7% to 147.5%, P < .01) and massive (+57.2%; 95% CI, 19.6% to 94.7%, P = .05) cuff tears. Anterior deltoid forces were significantly
Internal impingement in the etiology of rotator cuff tendinosis revisited.
Budoff, Jeffrey E; Nirschl, Robert P; Ilahi, Omer A; Rodin, Dennis M
2003-10-01
The theory of internal impingement holds that, in overhead athletes, repeated contact between the undersurface of the rotator cuff and the posterosuperior glenoid rim leads to articular-sided partial-thickness rotator cuff tears and superior labral lesions. However, we have noted this same constellation of lesions in our general patient population. These recreational athletic patients do not routinely assume the position of extreme abduction and external rotation, and thus are unlikely to experience significant internal impingement forces. The goal of this study was to document the prevalence of superior labral lesions in patients being treated for partial-thickness undersurface rotator cuff tears. Retrospective case series. We retrospectively reviewed the records of 75 shoulders arthroscopically treated for partial-thickness articular-sided rotator cuff tears. With the exception of one professional tennis player, no patients were playing sports at a professional or major college level. No professional or collegiate throwing athletes were included. The prevalence of these lesions and their association with recreational athletics was noted. We found that 55 of 75 (73.3%) shoulders with articular-sided partial-thickness rotator cuff tears also had superior labral lesions. A statistically significant increased prevalence of superior labral lesions in the dominant shoulder was seen (P =.03). In addition, our patients who engaged in overhand throwing had significantly fewer superior labral lesions in the dominant shoulders than did nonthrowers (P =.017). The "kissing lesions" of undersurface rotator cuff tears and posterosuperior labral damage may be explained by mechanisms other than "internal impingement."
[A novel technique for distal ureterectomy and bladder cuff excision].
Sotelo, R; Ramírez, D; Carmona, O; di Grazia, E; de Andrade, R; Giedelman, C; Pascal, Z; Gill, I; Desai, M
2011-03-01
We describe a novel endoscopic approach and provide a literature review for the "en bloc" dissection of the distal ureter and bladder cuff during laparoscopic radical nephroureterectomy using a transvesical single port approach under pneumovesicum. The procedure was performed in an 80-year old male with a history of gross hematuria due to left renal pelvic TCC and no history of prior bladder TCC. Laparoscopic radical nephroureterectomy was performed and the ureter was dissected down to the bladder and clipped. A single-port device was inserted transvesically and pneumovesicum established. A full thickness incision of the bladder around the ureter was performed with progressive intravesical mobilization of the distal ureter. Subsequently, a water-tight closure of the bladder defect was achieved. The distal ureter, together with the bladder cuff, was then delivered en bloc laparoscopically with the specimen. The operating time (LESS radical nephroureterectomy, RPLND, and bladder cuff excision) was 6hours and 15minutes. The bladder cuff time was 45minutes. There were no intra or postoperative complications and the catheter was removed after 6 days. Histopathological analysis showed kidney-invasive papillary urothelial cancer, pT3 pN0 (0/7) G3. The distal ureter and bladder cuff techniques have not yet been standardized. Management of the bladder cuff with a single port is feasible. Additional studies are needed to identify the best approach for management of the distal ureter at the time of laparoscopic nephroureterectomy. Copyright © 2010 AEU. Published by Elsevier Espana. All rights reserved.
[HEALING MODEL RESEARCH OF ROTATOR CUFF INJURY IN CANINE].
Ye, Wei; Bao, Nirong; Zhaq, Jianning
2016-04-01
To compare the difference of rotator cuff healing between different types of injury andbetween different repair methods, and to explore the animal model to accurately simulate the restorative process afterrepair of rotator cuff injury. Twelve adult male beagle dogs (weighing, 10-15 kg) were divided into 3 groups (n = 4) according to different processing methods: acute rotator cuff injury+Mason-Allen suture repair (group A), huge rotator cuff injury+Mason-Allen suture repair (group B), and huge rotator cuff injury+Mason-Allen combined with autogenous semitendinosus expansion suture repair (group C). The external fixation was used for immobilization after repair. After operation, the general situation of the animals was observed, and the infraspinatus tendon was harvested for gross observation at 6 weeks after operation. The biomechanical test of limit load and histological observation of tendon fibers were carried out. All the animals survived to the end of the experiment. All incisions healed well and no infection occurred. Gross observation showed more scar tissues at the end of infraspinatus muscle tendon than normal tendon in group A; no obvious tendon tissue was observed at the end of infraspinatus muscle tendon in group B; the infraspinatus muscle tendon was covered with some white scar tissue, but the tendon and the general direction could be observed in group C. The limit load of groups A, B, and C were (223.75 ± 24.28), (159.25 ± 34.87), and (233.25 ± 14.24) N respectively, group B was significantly lower than groups A and C (P < 0.05), and no significant differnce was found between group A and group C (P > 0.05). Histological observation showed normal arrangement of tendon fibers in group A; tendon fibers arranged disorderly in group B and tendon cells were significantly less than those of group A; tendon fibers arranged in neat in group C and tendon cells were more than those of group B. Canine autologous semitendinosus expansion repair of massive
Vaginal cancer is a rare type of cancer. It is more common in women 60 and older. You are also more likely to get it if you have had a human ... test can find abnormal cells that may be cancer. Vaginal cancer can often be cured in its ...
Tissue Engineering for Rotator Cuff Repair: An Evidence-Based Systematic Review
Maffulli, Nicola; Longo, Umile Giuseppe; Loppini, Mattia; Berton, Alessandra; Spiezia, Filippo; Denaro, Vincenzo
2012-01-01
The purpose of this systematic review was to address the treatment of rotator cuff tears by applying tissue engineering approaches to improve tendon healing, specifically platelet rich plasma (PRP) augmentation, stem cells, and scaffolds. Our systematic search was performed using the combination of the following terms: “rotator cuff”, “shoulder”, “PRP”, “platelet rich plasma”, “stemcells”, “scaffold”, “growth factors”, and “tissue engineering”. No level I or II studies were found on the use of scaffolds and stem cells for rotator cuff repair. Three studies compared rotator cuff repair with or without PRP augmentation. All authors performed arthroscopic rotator cuff repair with different techniques of suture anchor fixation and different PRP augmentation. The three studies found no difference in clinical rating scales and functional outcomes between PRP and control groups. Only one study showed clinical statistically significant difference between the two groups at the 3-month follow up. Any statistically significant difference in the rates of tendon rerupture between the control group and the PRP group was found using the magnetic resonance imaging. The current literature on tissue engineering application for rotator cuff repair is scanty. Comparative studies included in this review suggest that PRP augmented repair of a rotator cuff does not yield improved functional and clinical outcome compared with non-augmented repair at a medium and long-term followup. PMID:25098365
Triantis, Iasonas F; Demosthenous, Andreas
2008-06-01
Ideally, interference in neural measurements due to signals from nearby muscles can be completely eliminated with the use of tripolar cuffs, in combination with appropriate amplifier configurations, such as the quasi-tripole (QT) and the true-tripole (TT). The operation of these amplifiers, is based on the theoretical property of the nerve cuff to produce a linear relationship of potential versus distance along its length, internally, when external potentials appear between its ends. Thus, in principle, electroneurogram (ENG) recordings from an ideal tripolar cuff would be free from electromyogram (EMG) interference generated by nearby muscles. However, in practice the cuff exhibits non-ideal behaviour leading to "cuff imbalance". The main focus of this paper is to investigate the causes of cuff imbalance, to demonstrate that it should be incorporated as a main parameter in the theoretical ENG-recording cuff electrode model. In addition to cuff asymmetry and tissue growth, the proximity of the interference source to the cuff is shown to result in cuff imbalance. The influence of proximity imbalance on the performance of the QT and TT amplifiers is also considered. Proximity imbalance is studied using bioelectric field simulations and saline-bath experiments. Variation is observed with both distance (40 mm and 70 mm was examined) and orientation (0-180 degrees), with the latter causing a more severe effect especially when the source dipole and the cuff are vertical to each other. The simulations and measurements are in close agreement. Tissue growth imbalance and asymmetry imbalance are also investigated in vitro. Finally, the signal-to-interference ratio (SIR; ENG/EMG) of the QT and TT amplifiers is examined in the presence of cuff imbalance. It is shown that proximity imbalance results in their SIR to peak only at certain cuff orientation values. This important finding offers an insight as to why in practice ENG recordings using these amplifiers have been widely
Shabanian, Sheida; Khalili, Sima; Lorigooini, Zahra; Malekpour, Afsaneh; Heidari-Soureshjani, Saeid
2017-01-01
Vulvovaginal candidiasis is one of the most common infections of the genital tract in women that causes many complications. Therefore, we examined the clinical effect of ginger cream along with clotrimazole compared to vaginal clotrimazole alone in this study. This double-blind clinical trial was conducted on 67 women admitted to the Gynecology Clinic of Hajar Hospital with vaginal candidiasis. The patients were divided randomly into two groups of 33 and 34 people. The diagnosis was made according to clinical symptoms, wet smear, and culture. Ginger-clotrimazole vaginal cream 1% and clotrimazole vaginal cream 1% were administered to groups 1 and 2, respectively, once a day for 7 days and therapeutic effects and symptoms were evaluated in readmission. Data analysis was performed using SPSS version 22, t -test and Chi-square. The mean value of variables itching ( P > 0.05), burning ( P > 0.05), and cheesy secretion ( P < 0.05) in users of ginger-clotrimazole was less than the other group after the treatment. Recurrence in clotrimazole group was 48.5% and in ginger-clotrimazole group 51.2% during the 1-month follow-up with no significant difference. Study results showed that cream containing ginger and clotrimazole 1% was more effective and may be more useful than the clotrimazole to treat vaginal candidiasis.
Effectiveness Of Plain Shoulder Radiograph In Detecting Degenerate Rotator Cuff Tears.
Hussain, Adnan; Muzzammil, Muhammad; Butt, Faisal; Valsamis, Epaminondas Markos; Dwyer, Amitabh J
2018-01-01
Studies have demonstrated radiographic findings of sclerosis and cortical irregularity at the greater tuberosity can suggest a rotator cuff tear. Plain radiographs are the most easily attainable first-line investigations in evaluating shoulder injuries. This study determines the effectiveness in predicting degenerate rotator cuff tears by detecting radiographic changes on shoulder x-rays. Retrospective cross-sectional study with a consecutive series of patients conducted in Hinchingbrooke Hospital, Huntingdon, United Kingdom from January 2015 to June 2017. Anteroposterior shoulder radiographs of 150 symptomatic patients who underwent shoulder arthroscopy were independently analysed by surgeons who were blinded from the arthroscopic results. Patients aged fewer than 30 and over 70 years were excluded. Patients with advanced osteoarthritis and cuff tear arthropathy evident on x-rays were also excluded. Sixty-five patients included in the study had rotator cuff tears on arthroscopy. Radiographic changes were correlated with arthroscopic findings to determine this test's ability to predict degenerate rotator cuff tears. When both cortical irregularity and sclerosis were present on the plain radiograph, these signs had a sensitivity of 78.8% [95% CI 65.7, 87.8%] and specificity 77.4% [95% CI 67.2, 85.0%] with a positive predictive value of 68.3%, using contingency table analysis. The presence of cortical irregularity was found to be a better predictor of a tear as compared to sclerosis. This study concludes that plain radiograph are good modality for initial evaluation of rotator cuff tears and detecting when both cortical irregularity and sclerosis. Consideration of these radiographic findings serves as a useful adjunct in diagnostic workup and can guide subsequent investigations and treatment when evaluating rotator cuff tears of the shoulder.
Kumar, Rakesh; Gupta, Ekta; Kumar, Sunil; Rani Sharma, Kavita; Rani Gupta, Neera
2013-03-01
Softer endotracheal (ET) tubes are more difficult to navigate in the oropharynx than the stiffer polyvinyl chloride (PVC) tubes during nasotracheal intubation (NTI). Cuff inflation has been used to guide PVC tubes into the laryngeal inlet during blind NTI, but it has not been tested when performing NTI under direct laryngoscopic guidance. We assessed the role of cuff inflation in improving oropharyngeal navigation of 3 ET tubes of varying stiffness during direct laryngoscope-guided NTI. Simultaneously, we also assessed and compared the nasotracheal navigability and incidence of nasal injury with these ET tubes during cuff inflation-supplemented, laryngoscope-guided NTI. One hundred sixty-two adults were randomized to undergo NTI with either a conventional PVC (n = 54), wire reinforced (WR; n = 54) or a silicone-tipped WR (SWR; n = 54) ET tube. Ease of insertion of these tubes was assessed during passage from nose into oropharynx, from oropharynx into laryngeal inlet aided by cuff inflation if needed, and from laryngeal inlet into trachea. Nasal morbidity was assessed by a blinded observer. All ET tubes could be inserted into the trachea. Seventy-one of 162 ET tubes could be inserted from the oropharynx into the laryngeal inlet without cuff inflation. Eighty-six of the remaining 91 tubes that did not enter the laryngeal inlet without cuff inflation could be inserted when using the cuff inflation technique. Thus, a total of 157 ET tubes could be inserted into the laryngeal inlet with cuff inflation (95% confidence interval of difference of proportions between total number of tubes passed [157] and those without cuff inflation [71]: 53% [45%-61%]). The remaining 5 tubes had to be inserted with the help of Magill forceps. The incidence of epistaxis was lowest with the SWR tube (difference of proportions [95% confidence interval] SWR versus PVC 27% [8%-45%]; SWR versus WR 20% [1%-38%]; WR versus PVC 7% [-12% to 26%]). The cuff inflation technique consistently improved
Evaluation of the Risk Factors for a Rotator Cuff Retear After Repair Surgery.
Lee, Yeong Seok; Jeong, Jeung Yeol; Park, Chan-Deok; Kang, Seung Gyoon; Yoo, Jae Chul
2017-07-01
A retear is a significant clinical problem after rotator cuff repair. However, no study has evaluated the retear rate with regard to the extent of footprint coverage. To evaluate the preoperative and intraoperative factors for a retear after rotator cuff repair, and to confirm the relationship with the extent of footprint coverage. Cohort study; Level of evidence, 3. Data were retrospectively collected from 693 patients who underwent arthroscopic rotator cuff repair between January 2006 and December 2014. All repairs were classified into 4 types of completeness of repair according to the amount of footprint coverage at the end of surgery. All patients underwent magnetic resonance imaging (MRI) after a mean postoperative duration of 5.4 months. Preoperative demographic data, functional scores, range of motion, and global fatty degeneration on preoperative MRI and intraoperative variables including the tear size, completeness of rotator cuff repair, concomitant subscapularis repair, number of suture anchors used, repair technique (single-row or transosseous-equivalent double-row repair), and surgical duration were evaluated. Furthermore, the factors associated with failure using the single-row technique and transosseous-equivalent double-row technique were analyzed separately. The retear rate was 7.22%. Univariate analysis revealed that rotator cuff retears were affected by age; the presence of inflammatory arthritis; the completeness of rotator cuff repair; the initial tear size; the number of suture anchors; mean operative time; functional visual analog scale scores; Simple Shoulder Test findings; American Shoulder and Elbow Surgeons scores; and fatty degeneration of the supraspinatus, infraspinatus, and subscapularis. Multivariate logistic regression analysis revealed patient age, initial tear size, and fatty degeneration of the supraspinatus as independent risk factors for a rotator cuff retear. Multivariate logistic regression analysis of the single-row group
Vaginal mucosal flap as a sling preservation for the treatment of vaginal exposure of mesh.
Kim, Sea Young; Park, Jong Yeon; Kim, Han Kwon; Park, Chang Hoo; Kim, Sung Jin; Sung, Gi Teck; Park, Chang Myon
2010-06-01
Tension-free vaginal tape (TVT) procedures are used for the treatment of stress urinary incontinence in women. The procedures with synthetic materials can have a risk of vaginal erosion. We experienced transobturator suburethral sling (TOT) tape-induced vaginal erosion and report the efficacy of a vaginal mucosal covering technique. A total of 560 female patients diagnosed with stress urinary incontinence underwent TOT procedures at our hospital between January 2005 and August 2009. All patients succeeded in follow-ups, among which 8 patients (mean age: 50.5 years) presented with vaginal exposure of the mesh. A vaginal mucosal covering technique was performed under local anesthesia after administration of antibiotics and vaginal wound dressings for 3-4 days. Seven of the 8 patients complained of persistent vaginal discharge postoperatively. Two of the 8 patients complained of dyspareunia of their male partners. The one remaining patient was otherwise asymptomatic, but mesh erosion was discovered at the routine follow-up visit. Six of the 8 patients showed complete mucosal covering of the mesh after the operation (mean follow-up period: 16 moths). Vaginal mucosal erosion recurred in 2 patients, and the mesh was then partially removed. One patient had recurrent stress urinary incontinence. Vaginal mucosal covering as a sling preservation with continued patient continence may be a feasible and effective option for the treatment of vaginal exposure of mesh after TOT tape procedures.
Physiotherapy assessment of patients with rotator cuff pathology
2014-01-01
Pathology of the rotator cuff and sub-acromial bursa are considered to be the main cause of shoulder pain and dysfunction. In the absence of trauma, conservative care, including physiotherapy is the primary treatment. This paper aims to present the key features of a physiotherapy assessment, excluding diagnostic tests for rotator cuff pathology. It describes and explores how assessment can be used to direct management options and develop a treatment plan. PMID:27582940
Andreas Vesalius' five hundreth anniversary: initiation of the rotator cuff concept.
Brinkman, Romy J; Hage, J Joris
2015-12-01
The rotator cuff concept refers to the four scapulohumeral muscles that stabilize and rotate the humerus relative to the scapula. To date, the first description of the rotator cuff remained unidentified. In light of the 500th birthday of Andreas Vesalius (1515-1564) we searched his 1543 masterwork "Fabrica Corporis Humani Libri Septem" for references to the morphology and function of the rotator cuff muscles. Even though he distinguished three rather than four scapulohumeral muscles, Vesalius recognized the need for structures that prevent dislocation of the shoulder inherent to the morphology of the humeral caput and scapular socket. He recorded "three strong ligaments" and the "three muscles that rotate the arm" of which the tendons completely "embrace the ligaments of the joint" as such structures. Vesalius defined the rotator cuff concept avant la lettre.
Oh, Joo Han; McGarry, Michelle H; Jun, Bong Jae; Gupta, Akash; Chung, Kyung Chil; Hwang, James; Lee, Thay Q
2012-11-01
Complete repair in massive rotator cuff tear may not be possible, allowing for only partial repair. However, the effect of partial repair on glenohumeral biomechanics has not been evaluated. Therefore, the purpose of this study was to compare the rotational range of motion (ROM), glenohumeral kinematics, and gap formation at the repaired tendon edge following massive cuff tear and repair according to the degree of repair completion. Posterior fixation will restore the altered biomechanics of massive rotator cuff tear. Controlled laboratory study. Eight cadaveric shoulders were tested at 0°, 30°, and 60° of abduction in the scapular plane. Muscle loading was applied based on physiological muscle cross-sectional area ratios. Maximum internal (MaxIR) and external rotations (MaxER) were measured. Humeral head apex (HHA) position and gap formation at the repaired tendon edge were measured using a MicroScribe from MaxIR to MaxER in 30° increments. Testing was performed for intact, massive cuff tear, complete repair, and 4 types of partial repair. A repeated-measures analysis of variance was used to determine significant differences. Massive tear significantly increased ROM and shifted HHA superiorly in MaxIR at all abduction angles (P < .05). The complete repair restored ROM to intact (P < .05), while all partial repairs did not. Abnormal HHA elevation due to massive tear was restored by all repairs (P < .05). Release of the anterior single row alone and release of the marginal convergence significantly increased gap formation at the anterior tendon edge (P < .05). This study emphasizes the importance of anterior fixation in massive cuff tear to restore rotational range of motion and decrease gap formation at the repaired tendon edge and of posterior fixation to restore abnormal glenohumeral kinematics due to massive cuff tear. If complete repair of massive cuff tear is not possible, posterior cuff (infraspinatus) repair is necessary to restore abnormal glenohumeral
Lactobacilli Dominance and Vaginal pH: Why Is the Human Vaginal Microbiome Unique?
Miller, Elizabeth A; Beasley, DeAnna E; Dunn, Robert R; Archie, Elizabeth A
2016-01-01
The human vaginal microbiome is dominated by bacteria from the genus Lactobacillus , which create an acidic environment thought to protect women against sexually transmitted pathogens and opportunistic infections. Strikingly, lactobacilli dominance appears to be unique to humans; while the relative abundance of lactobacilli in the human vagina is typically >70%, in other mammals lactobacilli rarely comprise more than 1% of vaginal microbiota. Several hypotheses have been proposed to explain humans' unique vaginal microbiota, including humans' distinct reproductive physiology, high risk of STDs, and high risk of microbial complications linked to pregnancy and birth. Here, we test these hypotheses using comparative data on vaginal pH and the relative abundance of lactobacilli in 26 mammalian species and 50 studies ( N = 21 mammals for pH and 14 mammals for lactobacilli relative abundance). We found that non-human mammals, like humans, exhibit the lowest vaginal pH during the period of highest estrogen. However, the vaginal pH of non-human mammals is never as low as is typical for humans (median vaginal pH in humans = 4.5; range of pH across all 21 non-human mammals = 5.4-7.8). Contrary to disease and obstetric risk hypotheses, we found no significant relationship between vaginal pH or lactobacilli relative abundance and multiple metrics of STD or birth injury risk ( P -values ranged from 0.13 to 0.99). Given the lack of evidence for these hypotheses, we discuss two alternative explanations: the common function hypothesis and a novel hypothesis related to the diet of agricultural humans. Specifically, with regard to diet we propose that high levels of starch in human diets have led to increased levels of glycogen in the vaginal tract, which, in turn, promotes the proliferation of lactobacilli. If true, human diet may have paved the way for a novel, protective microbiome in human vaginal tracts. Overall, our results highlight the need for continuing research on non
Does the Rotator Cuff Tear Pattern Influence Clinical Outcomes After Surgical Repair?
Watson, Scott; Allen, Benjamin; Robbins, Chris; Bedi, Asheesh; Gagnier, Joel J; Miller, Bruce
2018-03-01
Limited literature exists regarding the influence of rotator cuff tear morphology on patient outcomes. To determine the effect of rotator cuff tear pattern (crescent, U-shape, L-shape) on patient-reported outcomes after rotator cuff repair. Cohort study; Level of evidence, 3. Patients undergoing arthroscopic repair of known full-thickness rotator cuff tears were observed prospectively at regular intervals from baseline to 1 year. The tear pattern was classified at the time of surgery as crescent, U-shaped, or L-shaped. Primary outcome measures were the Western Ontario Rotator Cuff Index (WORC), the American Shoulder and Elbow Surgeons (ASES), and a visual analog scale (VAS) for pain. The tear pattern was evaluated as the primary predictor while controlling for variables known to affect rotator cuff outcomes. Mixed-methods regression and analysis of variance (ANOVA) were used to examine the effects of tear morphology on patient-reported outcomes after surgical repair from baseline to 1 year. A total of 82 patients were included in the study (53 male, 29 female; mean age, 58 years [range, 41-75 years]). A crescent shape was the most common tear pattern (54%), followed by U-shaped (25%) and L-shaped tears (21%). There were no significant differences in outcome scores between the 3 groups at baseline. All 3 groups showed statistically significant improvement from baseline to 1 year, but analysis failed to show any predictive effect in the change in outcome scores from baseline to 1 year for the WORC, ASES, or VAS when tear pattern was the primary predictor. Further ANOVA also failed to show any significant difference in the change in outcome scores from baseline to 1 year for the WORC ( P = .96), ASES ( P = .71), or VAS ( P = .86). Rotator cuff tear pattern is not a predictor of functional outcomes after arthroscopic rotator cuff repair.
Extracorporeal shock wave therapy is not useful after arthroscopic rotator cuff repair.
Kim, Jae Yoon; Lee, Jae Sung; Park, Chi Woo
2012-12-01
Extracorporeal shock wave therapy (ESWT) is known to accelerate the healing of musculoskeletal tissue. The purpose of this study was to test the hypothesis that ESWT stimulates rotator cuff healing after arthroscopic repair. Seventy-one consecutive patients with a small- to large-sized rotator cuff tear underwent arthroscopic rotator cuff repair. The patients were randomized into two groups: 35 patients underwent ESWT at 6 weeks after surgery (ESWT group) and 36 patients did not (control group). Cuff integrity was evaluated with computed tomographic arthrography at 6 months after surgery. Constant and UCLA scores were measurable outcomes. All patients were available for a minimum one-year follow-up. The mean age of the ESWT and control groups was 59.4 (SD: 7.7) and 58.6 years (SD: 7.8) (n.s.). There were no significant differences in tear size and repair method between the two groups (n.s.). The mean Constant and UCLA scores, respectively, increased from 54.6 to 90.6 (P < 0.001) and from 18.5 to 27.4 (P < 0.001) in the ESWT group, and from 58.9 to 89.3 (P < 0.001) and 18.5 to 27.4 in the control group. Computed tomographic arthrography was performed in 26 patients from the ESWT group and 24 from the control group, and cuff integrity was maintained in 46 out of 50 patients. Definite re-tear was observed in two patients of the ESWT group and four of the controls. There were no complications associated with ESWT. This study failed to prove that ESWT stimulates rotator cuff healing after arthroscopic rotator cuff repair. Additional ESWT after rotator cuff repair could theoretically be advantageous, and it was proven to be safe in this study. II.
Effects of asymptomatic rotator cuff pathology on in vivo shoulder motion and clinical outcomes.
Baumer, Timothy G; Dischler, Jack; Mende, Veronica; Zauel, Roger; van Holsbeeck, Marnix; Siegal, Daniel S; Divine, George; Moutzouros, Vasilios; Bey, Michael J
2017-06-01
The incidence of asymptomatic rotator cuff tears has been reported to range from 15% to 39%, but the influence of asymptomatic rotator cuff pathology on shoulder function is not well understood. This study assessed the effects of asymptomatic rotator cuff pathology on shoulder kinematics, strength, and patient-reported outcomes. A clinical ultrasound examination was performed in 46 asymptomatic volunteers (age: 60.3 ± 7.5 years) with normal shoulder function to document the condition of their rotator cuff. The ultrasound imaging identified the participants as healthy (n = 14) or pathologic (n = 32). Shoulder motion was measured with a biplane x-ray imaging system, strength was assessed with a Biodex (Biodex Medical Systems, Inc., Shirley, NY, USA), and patient-reported outcomes were assessed using the Western Ontario Rotator Cuff Index and visual analog scale pain scores. Compared with healthy volunteers, those with rotator cuff pathology had significantly less abduction (P = .050) and elevation (P = .041) strength, their humerus was positioned more inferiorly on the glenoid (P = .018), and the glenohumeral contact path length was longer (P = .007). No significant differences were detected in the Western Ontario Rotator Cuff Index, visual analog scale, range of motion, or acromiohumeral distance. The differences observed between the healthy volunteers and those with asymptomatic rotator cuff pathology lend insight into the changes in joint mechanics, shoulder strength, and conventional clinical outcomes associated with the early stages of rotator cuff pathology. Furthermore, these findings suggest a plausible mechanical progression of kinematic and strength changes associated with the development of rotator cuff pathology. Copyright © 2016 Journal of Shoulder and Elbow Surgery Board of Trustees. Published by Elsevier Inc. All rights reserved.
Effects of Asymptomatic Rotator Cuff Pathology On In-Vivo Shoulder Motion and Clinical Outcomes
Baumer, Timothy G.; Dischler, Jack; Mende, Veronica; Zauel, Roger; van Holsbeeck, Marnix; Siegal, Daniel S.; Divine, George; Moutzouros, Vasilios; Bey, Michael J.
2017-01-01
Background The incidence of asymptomatic rotator cuff tears has been reported to range from 15–39%, but the influence of asymptomatic rotator cuff pathology on shoulder function is not well understood. The objective of this study was to assess the effects of asymptomatic rotator cuff pathology on shoulder kinematics, strength, and patient-reported outcomes. Methods 46 asymptomatic volunteers (age: 60.3±7.5) with normal shoulder function underwent a clinical ultrasound exam to document the condition of their rotator cuff. The ultrasound imaging identified subjects as healthy (n=14) or pathologic (n=32). Shoulder motion was measured with a biplane x-ray imaging system, strength was assessed with a Biodex, and patient-reported outcomes were assessed using the Western Ontario Rotator Cuff Index and VAS pain scores. Results Compared to healthy subjects, the subjects with rotator cuff pathology had significantly less abduction (p=0.050) and elevation (p=0.041) strength, their humerus was positioned more inferiorly on the glenoid (p=0.018), and the glenohumeral contact path length was longer (p=0.007). No significant differences were detected in terms of WORC, VAS, ROM, or acromiohumeral distance. Discussion The differences observed between the healthy subjects and subjects with asymptomatic rotator cuff pathology lend insight into the changes in joint mechanics, shoulder strength, and conventional clinical outcomes associated with the early stages of rotator cuff pathology. Furthermore, these findings suggest a plausible mechanical progression of kinematic and strength changes associated with the development of rotator cuff pathology. Level of evidence Basic Science Study, Kinesiology PMID:28131679
Clothing factors and vaginitis.
Heidrich, F E; Berg, A O; Bergman, J J
1984-10-01
Associations of clothing factors and vulvovaginal symptoms, signs, and microbiology were sought in 203 women seeking care at a university family medicine clinic. Clothing factors studied were use of panty hose, underwear for sleep, cotton lining panels, and pants vs skirts. Women wearing and not wearing panty hose had similar rates of vaginitis symptoms and signs, but yeast vaginitis was about three times more common among wearers. Relationships of other clothing factors to vaginitis were not found. Nonspecific vaginitis was not found to be related to clothing.
Cancienne, Jourdan M; Brockmeier, Stephen F; Rodeo, Scott A; Young, Chris; Werner, Brian C
2017-07-01
To evaluate the association of postoperative fluoroquinolone use following arthroscopic primary rotator cuff repair with failure requiring revision rotator cuff repair. An insurance database was queried for patients undergoing rotator cuff repair from 2007 to 2015. These patients were divided into three groups: (1) patients prescribed fluoroquinolones within 6 months postoperatively (divided into 0-2, 2-4, and 4-6 months), (2) a matched negative control cohort of patients not prescribed fluoroquinolones, and (3) a matched positive control cohort of patients prescribed fluoroquinolones between 6 and 18 months following rotator cuff repair. Rates of failure requiring revision rotator cuff repair were compared within 2 years. A total of 1292 patients were prescribed fluoroquinolones within 6 months after rotator cuff repair, including 442 within 2 months, 433 within 2 to 4 months, and 417 within 4 to 6 months, and were compared to 5225 matched negative controls and 1597 matched positive controls. The rate of revision rotator cuff repair was significantly higher in patients prescribed fluoroquinolones within 2 months (6.1 %) compared to matched negative (2.2 %, P = 0.0009) and positive controls (2.4 %, P = 0.0026). There were no significant differences in the rate of revision rotator cuff repair when fluoroquinolones were prescribed >2 months after rotator cuff repair. Early use of fluoroquinolones following rotator cuff repair was independently associated with significantly increased rates of failure requiring revision rotator cuff repair. This is the first clinical study examining the association of postoperative fluoroquinolone use with failure following arthroscopic rotator cuff repair. III.
Kindinger, Lindsay M; Bennett, Phillip R; Lee, Yun S; Marchesi, Julian R; Smith, Ann; Cacciatore, Stefano; Holmes, Elaine; Nicholson, Jeremy K; Teoh, T G; MacIntyre, David A
2017-01-19
Preterm birth is the primary cause of infant death worldwide. A short cervix in the second trimester of pregnancy is a risk factor for preterm birth. In specific patient cohorts, vaginal progesterone reduces this risk. Using 16S rRNA gene sequencing, we undertook a prospective study in women at risk of preterm birth (n = 161) to assess (1) the relationship between vaginal microbiota and cervical length in the second trimester and preterm birth risk and (2) the impact of vaginal progesterone on vaginal bacterial communities in women with a short cervix. Lactobacillus iners dominance at 16 weeks of gestation was significantly associated with both a short cervix <25 mm (n = 15, P < 0.05) and preterm birth <34 +0 weeks (n = 18; P < 0.01; 69% PPV). In contrast, Lactobacillus crispatus dominance was highly predictive of term birth (n = 127, 98% PPV). Cervical shortening and preterm birth were not associated with vaginal dysbiosis. A longitudinal characterization of vaginal microbiota (<18, 22, 28, and 34 weeks) was then undertaken in women receiving vaginal progesterone (400 mg/OD, n = 25) versus controls (n = 42). Progesterone did not alter vaginal bacterial community structure nor reduce L. iners-associated preterm birth (<34 weeks). L. iners dominance of the vaginal microbiota at 16 weeks of gestation is a risk factor for preterm birth, whereas L. crispatus dominance is protective against preterm birth. Vaginal progesterone does not appear to impact the pregnancy vaginal microbiota. Patients and clinicians who may be concerned about "infection risk" associated with the use of a vaginal pessary during high-risk pregnancy can be reassured.
Preoperative and post-operative sleep quality evaluation in rotator cuff tear patients.
Serbest, Sancar; Tiftikçi, Uğur; Askın, Aydogan; Yaman, Ferda; Alpua, Murat
2017-07-01
The aim of this study was to examine the potential relationship between subjective sleep quality and degree of pain in patients with rotator cuff repair. Thirty-one patients who underwent rotator cuff repair prospectively completed the Pittsburgh Sleep Quality Index, the Western Ontario Rotator Cuff Index, and the Constant and Murley shoulder scores before surgery and at 6 months after surgery. Preoperative demographic, clinical, and radiologic parameters were also evaluated. The study analysed 31 patients with a median age of 61 years. There was a significant difference preoperatively versus post-operatively in terms of all PSQI global scores and subdivisions (p < 0.001). A statistically significant improvement was determined by the Western Ontario Rotator Cuff Scale and the Constant and Murley shoulder scores (p ˂ 0.001). Sleep disorders are commonly seen in patients with rotator cuff tear, and after repair, there is an increase in the quality of sleep with a parallel improvement in shoulder functions. However, no statistically significant correlation was determined between arthroscopic procedures and the size of the tear and sleep quality. It is suggested that rotator cuff tear repair improves the quality of sleep and the quality of life. IV.
Preexisting Rotator Cuff Tears as a Predictor of Outcomes in National Football League Athletes.
Gibbs, Daniel B; Lynch, T Sean; Gombera, M Mustafa; Saltzman, Matthew D; Nuber, Gordon W; Schroeder, Gregory D; Labelle, Mark; Hollett, Brian P
A preexisting rotator cuff tear may affect the draft status and career performance of National Football League (NFL) players. Preexisting rotator cuff tears decrease a player's draft status, performance, and longevity in the NFL. Retrospective cohort study. Level 3. Medical reports of prospective NFL players during the NFL Scouting Combine from 2003 to 2011 were evaluated to identify players with a previous rotator cuff tear. Athletes were matched to control draftees without documented shoulder pathology by age, position, year drafted, and round drafted. Career statistics and performance scores were calculated. Between 2003 and 2011, 2965 consecutive athletes were evaluated. Forty-nine athletes had preexisting rotator cuff tears: 22 athletes underwent surgical intervention for their tear and 27 were treated nonoperatively. Those with a rotator cuff tear were significantly less likely to be drafted than those without a previous injury (55.1% vs 77.5%, P = 0.002). The 27 drafted athletes with preexisting rotator cuff tears started significantly fewer games (23.7 vs 43.0, P = 0.02) and played significantly fewer years (4.3 vs 5.7, P = 0.04) and significantly fewer games (47.1 vs 68.4, P = 0.04) than matched control athletes without rotator cuff tears. Athletes with a preexisting rotator cuff tear were less likely to be drafted and had decreased career longevity.
Proximal Long Head Biceps Rupture: A Predictor of Rotator Cuff Pathology.
Kowalczuk, Marcin; Kohut, Kevin; Sabzevari, Soheil; Naendrup, Jan-Hendrik; Lin, Albert
2018-04-01
To investigate whether acute rupture of the proximal long head biceps is a harbinger of disease of the nearby supraspinatus and subscapularis tendons. A retrospective chart review from February 1, 2008, to August 31, 2016, was performed at our institution identifying patients who presented with an acute (<12-week) history of "Popeye" deformity of the distal biceps and a magnetic resonance imaging (MRI) of the affected shoulder. MRI images were then reviewed in duplicate to determine supraspinatus and subscapularis tendon tear incidence, size, chronicity, and depth. The association between rotator cuff status and acute long head biceps rupture as well as patient age, sex, smoking status, hand dominance, and history of diabetes mellitus or trauma was then evaluated. A total of 116 patients were included in this study (mean age: 61.9 ± 10.9 years). A significant proportion (n = 99; incidence: 85%) were found to have some degree of supraspinatus or subscapularis tendon tearing on MRI (P < .001). These patients were also found to be significantly older compared with those with an intact rotator cuff (mean age 63.3 ± 10.7 vs 54.2 ± 9.2; P = .001). Full thickness rotator cuff tears were significantly more likely to involve the supraspinatus as opposed to the subscapularis (incidence: 44% and 21%; P = .002). Despite the expected association of rotator cuff disease with increasing patient age, the results of this study also affirm the hypothesis that inflammation in the rotator cuff interval signaled by rupture of the long head of biceps is a harbinger of rotator cuff disease. Clinicians should have a high index of suspicion regarding concomitant anterosuperior rotator cuff pathology in patients presenting with acute long head of biceps rupture. Early evaluation with advanced imaging should be strongly considered. Level IV, case series. Published by Elsevier Inc.
Surgery or conservative treatment for rotator cuff tear: a meta-analysis.
Ryösä, Anssi; Laimi, Katri; Äärimaa, Ville; Lehtimäki, Kaisa; Kukkonen, Juha; Saltychev, Mikhail
2017-07-01
Comparative evidence on treating rotator cuff tear is inconclusive. The objective of this review was to evaluate the evidence on effectiveness of tendon repair in reducing pain and improving function of the shoulder when compared with conservative treatment of symptomatic rotator cuff tear. Search on CENTRAL, MEDLINE, EMBASE, CINAHL, Web of Science and Pedro databases. Randomised controlled trials (RCT) comparing surgery and conservative treatment of rotator cuff tear. Study selection and extraction based on the Cochrane Handbook for Systematic reviews of Interventions. Random effects meta-analysis. Three identified RCTs involved 252 participants (123 cases and 129 controls). The risk of bias was considered low for all three RCTs. For Constant score, statistically insignificant effect size was 5.6 (95% CI -0.41 to 11.62) points in 1-year follow up favouring surgery and below the level of minimal clinically important difference. The respective difference in pain reduction was -0.93 (95% CI -1.65 to -0.21) cm on a 0-10 pain visual analogue scale favouring surgery. The difference was statistically significant (p = 0.012) in 1-year follow up but below the level of minimal clinically important difference. There is limited evidence that surgery is not more effective in treating rotator cuff tear than conservative treatment alone. Thus, a conservative approach is advocated as the initial treatment modality. Implications for Rehabilitation There is limited evidence that surgery is not more effective in treating rotator cuff tear than conservative treatment alone. There was no clinically significant difference between surgery and active physiotherapy in 1-year follow-up in improving Constant score or reducing pain caused by rotator cuff tear. As physiotherapy is less proneness to complications and less expensive than surgery, a conservative approach is advocated as the initial treatment modality to rotator cuff tears.
Effect of vaginal or systemic estrogen on dynamics of collagen assembly in the rat vaginal wall.
Montoya, T Ignacio; Maldonado, P Antonio; Acevedo, Jesus F; Word, R Ann
2015-02-01
The objective of this study was to compare the effects of systemic and local estrogen treatment on collagen assembly and biomechanical properties of the vaginal wall. Ovariectomized nulliparous rats were treated with estradiol or conjugated equine estrogens (CEEs) either systemically, vaginal CEE, or vaginal placebo cream for 4 wk. Low-dose local CEE treatment resulted in increased vaginal epithelial thickness and significant vaginal growth without uterine hyperplasia. Furthermore, vaginal wall distensibility increased without compromise of maximal force at failure. Systemic estradiol resulted in modest increases in collagen type I with no change in collagen type III mRNA. Low-dose vaginal treatment, however, resulted in dramatic increases in both collagen subtypes whereas moderate and high dose local therapies were less effective. Consistent with the mRNA results, low-dose vaginal estrogen resulted in increased total and cross-linked collagen content. The inverse relationship between vaginal dose and collagen expression may be explained in part by progressive downregulation of estrogen receptor-alpha mRNA with increasing estrogen dose. We conclude that, in this menopausal rat model, local estrogen treatment increased total and cross-linked collagen content and markedly stimulated collagen mRNA expression in an inverse dose-effect relationship. High-dose vaginal estrogen resulted in downregulation of estrogen receptor-alpha and loss of estrogen-induced increases in vaginal collagen. These results may have important clinical implications regarding the use of local vaginal estrogen therapy and its role as an adjunctive treatment in women with loss of vaginal support. © 2015 by the Society for the Study of Reproduction, Inc.
Dose-Response Evaluation of Braslet-M Occlusion Cuffs
NASA Technical Reports Server (NTRS)
Ebert, Douglas; Garcia, Kathleen; Sargsyan, Ashot E.; Ham, David; Hamilton, Douglas; Dulchavsky, Scott A.
2010-01-01
Introduction: Braslet-M is a set of special elasticized thigh cuffs used by the Russian space agency to reduce the effects of the head-ward fluid shift during early adaptation to microgravity by sequestering fluid in the lower extremities. Currently, no imaging modalities are used in the calibration of the device, and the pressure required to produce a predictable physiological response is unknown. This investigation intends to relate the pressure exerted by the cuffs to the extent of fluid redistribution and commensurate physiological effects. Materials and Methods: Ten healthy subjects with standardized fluid intake participated in the study. Data collection included femoral and internal jugular vein imaging in two orthogonal planes, pulsed Doppler of cervical and femoral vessels and middle cerebral artery, optic nerve imaging, and echocardiography. Braslet-M cuff pressure was monitored at the skin interface using pre-calibrated pressure sensors. Using 6 and 30 head-down tilt in two separate sessions, the effect of Braslet-M was assessed while incrementally tightening the cuffs. Cuffs were then simultaneously released to document the resulting hemodynamic change. Results: Preliminary analysis shows correlation between physical pressure exerted by the Braslet-M device and several parameters such as jugular and femoral vein cross-sections, resistivity of the lower extremity vascular bed, and others. A number of parameters reflect blood redistribution and will be used to determine the therapeutic range of the device and to prevent unsafe application. Conclusion: Braslet-M exerts a physical effect that can be measured and correlated with many changes in central and peripheral hemodynamics. Analysis of the full data set will be required to make definitive recommendations regarding the range of safe therapeutic application. Objective data and subjective responses suggest that a safer and equally effective use of Braslet can be achieved when compared with the current
[Rotator cuff repair: single- vs double-row. Clinical and biomechanical results].
Baums, M H; Kostuj, T; Klinger, H-M; Papalia, R
2016-02-01
The goal of rotator cuff repair is a high initial mechanical stability as a requirement for adequate biological recovery of the tendon-to-bone complex. Notwithstanding the significant increase in publications concerning the topic of rotator cuff repair, there are still controversies regarding surgical technique. The aim of this work is to present an overview of the recently published results of biomechanical and clinical studies on rotator cuff repair using single- and double-row techniques. The review is based on a selective literature research of PubMed, Embase, and the Cochrane Database on the subject of the clinical and biomechanical results of single- and double-row repair. In general, neither the biomechanical nor the clinical evidence can recommend the use of a double-row concept for the treatment for every rotator cuff tear. Only tears of more than 3 cm seem to benefit from better results on both imaging and in clinical outcome studies compared with the use of single-row techniques. Despite a significant increase in publications on the surgical treatment of rotator cuff tears in recent years, the clinical results were not significantly improved in the literature so far. Unique information and algorithms, from which the optimal treatment of this entity can be derived, are still inadequate. Because of the cost-effectiveness and the currently vague evidence, the double-row techniques cannot be generally recommended for the repair of all rotator cuff tears.
Arthroscopic treatment options for irreparable rotator cuff tears of the shoulder
Anley, Cameron M; Chan, Samuel KL; Snow, Martyn
2014-01-01
The management of patients with irreparable rotator cuff tears remains a challenge for orthopaedic surgeons with the final treatment option in many algorithms being either a reverse shoulder arthroplasty or a tendon transfer. The long term results of these procedures are however still widely debated, especially in younger patients. A variety of arthroscopic treatment options have been proposed for patients with an irreparable rotator cuff tear without the presence of arthritis of the glenohumeral joint. These include a simple debridement with or without a biceps tenotomy, partial rotator cuff repair with or without an interval slide, tuberplasty, graft interposition of the rotator cuff, suprascapular nerve ablation, superior capsule reconstruction and insertion of a biodegradable spacer (Inspace) to depress the humeral head. These options should be considered as part of the treatment algorithm in patients with an irreparable rotator cuff and could be used as either as an interim procedure, delaying the need for more invasive surgery in the physiologically young and active, or as potential definitive procedures in the medically unfit. The aim of this review is to highlight and summarise arthroscopic procedures and the results thereof currently utilised in the management of these challenging patients. PMID:25405083
[Continuous inflation of a leaking cuff of an intubation tube].
Boussard, N; Helmer, J; Rose, E; Lascombes, P
1988-01-01
Perforation of the cuff of the endotracheal tube peroperatively is a very serious problem, especially when it occurs in a patient prone on an orthopaedic table. This is even more dramatic when the patient is not breathing spontaneously and he cannot be turned over to be reintubated. Given the unusual character of this situation, an apparatus has been designed to keep the cuff inflated permanently. It was a circuit consisting of a manual pressure valve, flexible tubing, a peripheral catheter and the cuff supply tube. The gas used was medical air at 3 bar pressure. This method proved perfectly safe and efficient, the operation having continued without reintubation.
The Role of Platelet Rich Plasma (PRP) and Other Biologics for Rotator Cuff Repair.
Greenspoon, Joshua A; Moulton, Samuel G; Millett, Peter J; Petri, Maximilian
2016-01-01
Surgical treatment of rotator cuff tears has consistently demonstrated good clinical and functional outcomes. However, in some cases, the rotator cuff fails to heal. While improvements in rotator cuff constructs and biomechanics have been made, the role of biologics to aid healing is currently being investigated. A selective literature search was performed and personal surgical experiences are reported. Biologic augmentation of rotator cuff repairs can for example be performed wtableith platelet-rich plasma (PRP) and mesenchymal stem cells (MSCs). Clinical results on PRP application have been controversial. Application of MSCs has shown promise in animal studies, but clinical data on its effectiveness is presently lacking. The role of Matrix Metalloproteinase (MMP) inhibitors is another interesting field for potential targeted drug therapy after rotator cuff repair. Large randomized clinical studies need to confirm the benefit of these approaches, in order to eventually lower retear rates and improve clinical outcomes after rotator cuff repair.
Irreparable Rotator Cuff Tears: Restoring Joint Kinematics by Tendon Transfers
Greenspoon, Joshua A.; Millett, Peter J.; Moulton, Samuel G.; Petri, Maximilian
2016-01-01
Background: Tendon transfers can be a surgical treatment option in managing younger, active patients with massive irreparable rotator cuff tears. The purpose of this article is to provide an overview of the use of tendon transfers to treat massive irreparable rotator cuff tears and to summarize clinical outcomes. Methods: A selective literature search was performed and personal surgical experiences are reported. Results: Latissimus dorsi transfers have been used for many years in the management of posterosuperior rotator cuff tears with good reported clinical outcomes. It can be transferred without or with the teres major (L’Episcopo technique). Many surgical techniques have been described for latissimus dorsi transfer including single incision, double incision, and arthroscopically assisted transfer. Transfer of the pectoralis major tendon is the most common tendon transfer procedure performed for anterosuperior rotator cuff deficiencies. Several surgical techniques have been described, however transfer of the pectoralis major beneath the coracoid process has been found to most closely replicate the force vector that is normally provided by the intact subscapularis. Conclusion: Tendon transfers can be used successfully in the management of younger patients with massive irreparable rotator cuff tears and minimal glenohumeral arthritis. Improvements in clinical outcomes scores and range of motion have been demonstrated. This can delay arthroplasty, which is of particular importance for younger patients with high functional demands. PMID:27708730
Rotator cuff tears in children and adolescents: experience at a large pediatric hospital.
Zbojniewicz, Andrew M; Maeder, Matthew E; Emery, Kathleen H; Salisbury, Shelia R
2014-06-01
Prior literature, limited to small case series and case reports, suggests that rotator cuff tears are rare in adolescents. However, we have identified rotator cuff tears in numerous children and adolescents who have undergone shoulder MRI evaluation. The purpose of this study is to describe the prevalence and characteristics of rotator cuff tears in children and adolescents referred for MRI evaluation of the shoulder at a large pediatric hospital and to correlate the presence of rotator cuff tears with concurrent labral pathology, skeletal maturity and patient activity and outcomes. We reviewed reports from 455 consecutive non-contrast MRI and magnetic resonance arthrogram examinations of the shoulder performed during a 2-year period, and following exclusions we yielded 205 examinations in 201 patients (ages 8-18 years; 75 girls, 126 boys). Rotator cuff tears were classified by tendon involved, tear thickness (partial or full), surface and location of tear (when partial) and presence of delamination. We recorded concurrent labral pathology when present. Physeal patency of the proximal humerus was considered open, closing or closed. Statistical analysis was performed to evaluate for a relationship between rotator cuff tears and degree of physeal patency. We obtained patient activity at the time of injury, surgical reports and outcomes from clinical records when available. Twenty-five (12.2%) rotator cuff tears were identified in 17 boys and 7 girls (ages 10-18 years; one patient had bilateral tears). The supraspinatus tendon was most frequently involved (56%). There were 2 full-thickness and 23 partial-thickness tears with articular-side partial-thickness tears most frequent (78%). Insertional partial-thickness tears were more common (78%) than critical zone tears (22%) and 10 (43%) partial-thickness tears were delamination tears. Nine (36%) patients with rotator cuff tears had concurrent labral pathology. There was no statistically significant relationship between
... Patient Education FAQs Assisted Vaginal Delivery Patient Education Pamphlets - Spanish Assisted Vaginal Delivery FAQ192, February 2016 PDF ... on Patient Safety For Patients Patient FAQs Spanish Pamphlets Teen Health About ACOG About Us Leadership & Governance ...
Vaginal estrogen: a dual-edged sword in postoperative healing of the vaginal wall.
Ripperda, Christopher M; Maldonado, Pedro Antonio; Acevedo, Jesus F; Keller, Patrick W; Akgul, Yucel; Shelton, John M; Word, Ruth Ann
2017-07-01
Reconstructive surgery for pelvic organ prolapse is plagued with high failure rates possibly due to impaired healing or regeneration of the vaginal wall. Here, we tested the hypothesis that postoperative administration of local estrogen, direct injection of mesenchymal stem cells (MSCs), or both lead to improved wound healing of the injured vagina in a menopausal rat model. Ovariectomized rats underwent surgical injury to the posterior vaginal wall and were randomized to treatment with placebo (n = 41), estrogen cream (n = 47), direct injection of MSCs (n = 39), or both (n = 43). MSCs did not survive after injection and had no appreciable effects on healing of the vaginal wall. Acute postoperative administration of vaginal estrogen altered the response of the vaginal wall to injury with decreased stiffness, decreased collagen content, and decreased expression of transcripts for matrix components in the stromal compartment. Conversely, vaginal estrogen resulted in marked proliferation of the epithelial layer and increased expression of genes related to epithelial barrier function and protease inhibition. Transcripts for genes involved in chronic inflammation and adaptive immunity were also down-regulated in the estrogenized epithelium. Collectively, these data indicate that, in contrast to the reported positive effects of preoperative estrogen on the uninjured vagina, acute administration of postoperative vaginal estrogen has adverse effects on the early phase of healing of the stromal layer. In contrast, postoperative estrogen plays a positive role in healing of the vaginal epithelium after injury.
Vaginal estrogen: a dual-edged sword in postoperative healing of the vaginal wall
Ripperda, Christopher M.; Maldonado, Pedro Antonio; Acevedo, Jesus F.; Keller, Patrick W.; Akgul, Yucel; Shelton, John M.; Word, Ruth Ann
2017-01-01
Abstract Objective: Reconstructive surgery for pelvic organ prolapse is plagued with high failure rates possibly due to impaired healing or regeneration of the vaginal wall. Here, we tested the hypothesis that postoperative administration of local estrogen, direct injection of mesenchymal stem cells (MSCs), or both lead to improved wound healing of the injured vagina in a menopausal rat model. Methods: Ovariectomized rats underwent surgical injury to the posterior vaginal wall and were randomized to treatment with placebo (n = 41), estrogen cream (n = 47), direct injection of MSCs (n = 39), or both (n = 43). Results: MSCs did not survive after injection and had no appreciable effects on healing of the vaginal wall. Acute postoperative administration of vaginal estrogen altered the response of the vaginal wall to injury with decreased stiffness, decreased collagen content, and decreased expression of transcripts for matrix components in the stromal compartment. Conversely, vaginal estrogen resulted in marked proliferation of the epithelial layer and increased expression of genes related to epithelial barrier function and protease inhibition. Transcripts for genes involved in chronic inflammation and adaptive immunity were also down-regulated in the estrogenized epithelium. Conclusions: Collectively, these data indicate that, in contrast to the reported positive effects of preoperative estrogen on the uninjured vagina, acute administration of postoperative vaginal estrogen has adverse effects on the early phase of healing of the stromal layer. In contrast, postoperative estrogen plays a positive role in healing of the vaginal epithelium after injury. PMID:28169915
Lactobacilli Dominance and Vaginal pH: Why Is the Human Vaginal Microbiome Unique?
Miller, Elizabeth A.; Beasley, DeAnna E.; Dunn, Robert R.; Archie, Elizabeth A.
2016-01-01
The human vaginal microbiome is dominated by bacteria from the genus Lactobacillus, which create an acidic environment thought to protect women against sexually transmitted pathogens and opportunistic infections. Strikingly, lactobacilli dominance appears to be unique to humans; while the relative abundance of lactobacilli in the human vagina is typically >70%, in other mammals lactobacilli rarely comprise more than 1% of vaginal microbiota. Several hypotheses have been proposed to explain humans' unique vaginal microbiota, including humans' distinct reproductive physiology, high risk of STDs, and high risk of microbial complications linked to pregnancy and birth. Here, we test these hypotheses using comparative data on vaginal pH and the relative abundance of lactobacilli in 26 mammalian species and 50 studies (N = 21 mammals for pH and 14 mammals for lactobacilli relative abundance). We found that non-human mammals, like humans, exhibit the lowest vaginal pH during the period of highest estrogen. However, the vaginal pH of non-human mammals is never as low as is typical for humans (median vaginal pH in humans = 4.5; range of pH across all 21 non-human mammals = 5.4–7.8). Contrary to disease and obstetric risk hypotheses, we found no significant relationship between vaginal pH or lactobacilli relative abundance and multiple metrics of STD or birth injury risk (P-values ranged from 0.13 to 0.99). Given the lack of evidence for these hypotheses, we discuss two alternative explanations: the common function hypothesis and a novel hypothesis related to the diet of agricultural humans. Specifically, with regard to diet we propose that high levels of starch in human diets have led to increased levels of glycogen in the vaginal tract, which, in turn, promotes the proliferation of lactobacilli. If true, human diet may have paved the way for a novel, protective microbiome in human vaginal tracts. Overall, our results highlight the need for continuing research on non
Tail-Cuff Technique and Its Influence on Central Blood Pressure in the Mouse.
Wilde, Elena; Aubdool, Aisah A; Thakore, Pratish; Baldissera, Lineu; Alawi, Khadija M; Keeble, Julie; Nandi, Manasi; Brain, Susan D
2017-06-27
Reliable measurement of blood pressure in conscious mice is essential in cardiovascular research. Telemetry, the "gold-standard" technique, is invasive and expensive and therefore tail-cuff, a noninvasive alternative, is widely used. However, tail-cuff requires handling and restraint during measurement, which may cause stress affecting blood pressure and undermining reliability of the results. C57Bl/6J mice were implanted with radio-telemetry probes to investigate the effects of the steps of the tail-cuff technique on central blood pressure, heart rate, and temperature. This included comparison of handling techniques, operator's sex, habituation, and influence of hypertension induced by angiotensin II. Direct comparison of measurements obtained by telemetry and tail-cuff were made in the same mouse. The results revealed significant increases in central blood pressure, heart rate, and core body temperature from baseline following handling interventions without significant difference among the different handling technique, habituation, or sex of the investigator. Restraint induced the largest and sustained increase in cardiovascular parameters and temperature. The tail-cuff readings significantly underestimated those from simultaneous telemetry recordings; however, "nonsimultaneous" telemetry, obtained in undisturbed mice, were similar to tail-cuff readings obtained in undisturbed mice on the same day. This study reveals that the tail-cuff technique underestimates the core blood pressure changes that occur simultaneously during the restraint and measurement phases. However, the measurements between the 2 techniques are similar when tail-cuff readings are compared with telemetry readings in the nondisturbed mice. The differences between the simultaneous recordings by the 2 techniques should be recognized by researchers. © 2017 The Authors. Published on behalf of the American Heart Association, Inc., by Wiley.
Analysis of Direct Costs of Outpatient Arthroscopic Rotator Cuff Repair.
Narvy, Steven J; Ahluwalia, Avtar; Vangsness, C Thomas
2016-01-01
Arthroscopic rotator cuff surgery is one of the most commonly performed orthopedic surgical procedures. We conducted a study to calculate the direct cost of arthroscopic repair of rotator cuff tears confirmed by magnetic resonance imaging. Twenty-eight shoulders in 26 patients (mean age, 54.5 years) underwent primary rotator cuff repair by a single fellowship-trained arthroscopic surgeon in the outpatient surgery center of a major academic medical center. All patients had interscalene blocks placed while in the preoperative holding area. Direct costs of this cycle of care were calculated using the time-driven activity-based costing algorithm. Mean time in operating room was 148 minutes; mean time in recovery was 105 minutes. Calculated surgical cost for this process cycle was $5904.21. Among material costs, suture anchor costs were the main cost driver. Preoperative bloodwork was obtained in 23 cases, adding a mean cost of $111.04. Our findings provide important preliminary information regarding the direct economic costs of rotator cuff surgery and may be useful to hospitals and surgery centers negotiating procedural reimbursement for the increased cost of repairing complex tears.
True vaginal prolapse in a bitch.
Alan, M; Cetin, Y; Sendag, S; Eski, F
2007-08-01
Frequently, vaginal fold prolapse is the protrusion of edematous vaginal tissue into and through the opening of the vulva occurring during proestrus and estrus stages of the sexual cycle. True vaginal prolapse may occur near parturition, as the concentration of serum progesterone declines and the concentration of serum oestrogen increases. In the bitch, this type of true vaginal prolapse is a very rare condition. This short communication describes a 5-year-old female, cross-breed dog in moderate condition, weighing 33 kg, with distocia and true vaginal prolapse. Abdominal palpation and transabdominal ultrasonography revealed live and dead foetuses in the uterine horns. One dead and four live fetuses were removed from uterus by cesarean section. The ovariohysterectomy was performed after repositioning the vaginal wall with a combination of traction from within the abdomen and external manipulation through the vulva. Re-occurrence of a vaginal prolapse was not observed and the bitch recovered completely after the surgical therapy. Compared to other vaginal disorders, vaginal prolapse is an uncommon condition in the bitch. In the present case, extreme tenesmus arising from distocia may have predisposed to the vaginal prolapse. The cause of dystocia was probably the disposition of the first foetus. We concluded that the vaginal prolapse was the result of dystocia in the present case.
The impact of rotator cuff tendinopathy on proprioception, measuring force sensation.
Maenhout, Annelies G; Palmans, Tanneke; De Muynck, Martine; De Wilde, Lieven F; Cools, Ann M
2012-08-01
The impact of rotator cuff tendinopathy and related impingement on proprioception is not well understood. Numerous quantitative and qualitative changes in shoulder muscles have been shown in patients with rotator cuff tendinopathy. These findings suggest that control of force might be affected. This investigation wants to evaluate force sensation, a submodality of proprioception, in patients with rotator cuff tendinopathy. Thirty-six patients with rotator cuff tendinopathy and 30 matched healthy subjects performed force reproduction tests to isometric external and internal rotation to investigate how accurately they could reproduce a fixed target (50% MVC). Relative error, constant error, and force steadiness were calculated to evaluate respectively magnitude of error made during the test, direction of this error (overshoot or undershoot), and fluctuations of produced forces. Patients significantly overshoot the target (mean, 6.04% of target) while healthy subjects underestimate the target (mean, -5.76% of target). Relative error and force steadiness are similar in patients with rotator cuff tendinopathy and healthy subjects. Force reproduction tests, as executed in this study, were found to be highly reliable (ICC 0.849 and 0.909). Errors were significantly larger during external rotation tests, compared to internal rotation. Patients overestimate the target during force reproduction tests. This should be taken into account in the rehabilitation of patients with rotator cuff tendinopathy; however, precision of force sensation and steadiness of force exertion remains unaltered. This might indicate that control of muscle force is preserved. Copyright © 2012 Journal of Shoulder and Elbow Surgery Board of Trustees. Published by Mosby, Inc. All rights reserved.
Incidence and treatment of postoperative stiffness following arthroscopic rotator cuff repair.
Huberty, David P; Schoolfield, John D; Brady, Paul C; Vadala, Antonio P; Arrigoni, Paolo; Burkhart, Stephen S
2009-08-01
The purpose of this study was to determine the incidence of clinically significant postoperative stiffness following arthroscopic rotator cuff repair. This study also sought to determine the clinical and surgical factors that were associated with higher rates of postoperative stiffness. Finally, we analyzed the result of arthroscopic lysis of adhesions and capsular release for treatment of patients who developed refractory postoperative stiffness 4 to 19 months (median, 8 months) following arthroscopic rotator cuff repair. A retrospective review of a consecutive series of arthroscopic rotator cuff repairs was conducted. During a 3-year time period, the senior author (S.S.B.) performed 489 arthroscopic rotator cuff repairs. The operative indications, technique of the rotator cuff repair, and the rehabilitation protocol were essentially unchanged during this time period. Demographic data, comorbid medical conditions, rotator cuff tear description, technique of repair, and concomitant surgical procedures were evaluated for their effect on stiffness. All office evaluations were reviewed to determine the pre- and postoperative motion, pain scores, functional strength, and patient satisfaction. Patients who were dissatisfied because of the development of postoperative stiffness underwent secondary arthroscopic lysis of adhesions. The final result of the secondary lysis of adhesions and capsular release were analyzed. In total, 24 patients (4.9%) were dissatisfied with the result of their procedure because of the development of postoperative stiffness, which was more likely (P < .05) to develop in patients with Workers' Compensation insurance (8.6%), patients younger than 50 years of age (8.6%), those with a coexisting diagnosis of calcific tendonitis (16.7%) or adhesive capsulitis (15.0%) requiring additional postoperative therapy, partial articular-sided tendon avulsion (PASTA) type rotator cuff tear (13.5%), or concomitant labral repair (11.0%). Patients with
Akiyama, Yasuhiro; Okamoto, Shogo; Yamada, Yoji; Ishiguro, Kenji
2016-07-01
Continuous use of wearable robots can cause skin injuries beneath the cuffs of robots. To prevent such injuries, understanding the contact behavior of the cuff is important. Thus far, this contact behavior has not been studied because of the difficulty involved in measuring the slippage under the cuff. In this study, for the first time, the relative displacement, slippage, and interaction force and moment at the thigh cuff of a robot during sit-to-stand motion were measured using an instrumented cuff, which was developed for this purpose. The results indicated that the slippage and relative displacement under the cuff was uneven because of the rotation of the cuff, which suggests that the risk of skin injuries is different at different positions. Especially, the skin closer to the hip showed larger dynamism, with a maximum slippage of approximately 10 mm and a displacement of 20 mm during motion. Another important phenomenon was the individual difference among subjects. During motion, the interaction force, moment, and slippage of some subjects suddenly increased. Such behavior results in stress concentration, which increases the risk of skin injuries. These analyses are intended to understand how skin injuries are caused and to design measures to prevent such injuries.
Differences in Risk Factors for Rotator Cuff Tears between Elderly Patients and Young Patients.
Watanabe, Akihisa; Ono, Qana; Nishigami, Tomohiko; Hirooka, Takahiko; Machida, Hirohisa
2018-02-01
It has been unclear whether the risk factors for rotator cuff tears are the same at all ages or differ between young and older populations. In this study, we examined the risk factors for rotator cuff tears using classification and regression tree analysis as methods of nonlinear regression analysis. There were 65 patients in the rotator cuff tears group and 45 patients in the intact rotator cuff group. Classification and regression tree analysis was performed to predict rotator cuff tears. The target factor was rotator cuff tears; explanatory variables were age, sex, trauma, and critical shoulder angle≥35°. In the results of classification and regression tree analysis, the tree was divided at age 64. For patients aged≥64, the tree was divided at trauma. For patients aged<64, the tree was divided at critical shoulder angle≥35°. The odds ratio for critical shoulder angle≥35° was significant for all ages (5.89), and for patients aged<64 (10.3) while trauma was only a significant factor for patients aged≥64 (5.13). Age, trauma, and critical shoulder angle≥35° were related to rotator cuff tears in this study. However, these risk factors showed different trends according to age group, not a linear relationship.
Federal Register 2010, 2011, 2012, 2013, 2014
2011-02-25
... DEPARTMENT OF ENERGY Federal Energy Regulatory Commission [Project No. 13880-000] Cuffs Run Pumped..., Motions To Intervene, and Competing Applications On November 18, 2010, Cuffs Run Pumped Storage, LLC filed... to study the feasibility of the Cuffs Run Pumped Storage Project, located on Cuffs Run and the...
Ozalp, E; Tanir, H M; Sener, T
2010-01-01
To compare the impact of a dinoprostone vaginal insert and intravenous oxytocin in reducing blood loss of women undergoing vaginal or cesarean delivery. This study was conducted among term singleton pregnancies delivered vaginally or by elective cesarean section. In the vaginally delivered cases, active management of the third stage of labor was conducted. During cesarean delivery, 20 IU of intravenous oxytocin was administered. Women, who either delivered via the vaginal or abdominal route, were then randomly allocated to receive 10 mg vaginal dinoprostone insert for 12 hours (group I, n: 100) or intravenous oxytocin (group II, n: 100), respectively. Mean blood loss and need for additional uterotonics and postpartum hemoglobin and hematocrit levels at 24 and 36 hours after delivery did not differ between the two groups. Women allocated to the dinoprostone vaginal insert arm experienced more nausea and vomiting. Dinoprostone vaginal insert was as effective as intravenous oxytocin in the prevention of postpartum blood loss.
Evaluation of vaginal complaints.
Anderson, Matthew R; Klink, Kathleen; Cohrssen, Andreas
2004-03-17
Vaginal symptoms are one of the most common reasons for gynecological consultation. Clinicians have traditionally diagnosed vaginal candidiasis, bacterial vaginosis, and vaginal trichomoniasis using some combination of physical examination, pH, the wet mount, and the whiff test. To evaluate the role of the clinical examination and determine the positive and negative likelihood ratios (LRs) for the diagnosis of vaginal candidiasis, bacterial vaginosis, and vaginal trichomoniasis. Using a structured literature review, we abstracted information on sensitivity and specificity for symptoms, signs, and office laboratory procedures. We chose published (1966 to April 2003) articles that appeared in the MEDLINE database and were indexed under the combined search terms of diagnosis with vaginitis, vaginal discharge, candidiasis, bacterial vaginosis, and trichomoniasis. Included studies of symptomatic premenopausal women seen in primary care settings. Tests were evaluated only if they would provide diagnostic information during the office visit and were compared with an acceptable criterion standard. All 3 authors extracted the data and computed sensitivity and specificity from each article independently. The absence of standard definitions for symptoms and signs made it impossible to combine results across studies. Symptoms alone do not allow clinicians to distinguish confidently between the causes of vaginitis. However, a patient's lack of itching makes candidiasis less likely (range of LRs, 0.18 [95% confidence interval [CI], 0.05-0.70] to 0.79 [95% CI, 0.72-0.87]) and lack of perceived odor makes bacterial vaginosis unlikely (LR, 0.07 [95% CI, 0.01-0.51]). Similarly, physical examination signs are limited in their diagnostic power. The presence of inflammatory signs is associated with candidiasis (range of LRs, 2.1 [95% CI, 1.5-2.8] to 8.4 [95% CI, 2.3-31]). Presence of a "high cheese" odor on examination is predictive of bacterial vaginosis (LR, 3.2 [95% CI, 2
Does the Rotator Cuff Tear Pattern Influence Clinical Outcomes After Surgical Repair?
Watson, Scott; Allen, Benjamin; Robbins, Chris; Bedi, Asheesh; Gagnier, Joel J.; Miller, Bruce
2018-01-01
Background: Limited literature exists regarding the influence of rotator cuff tear morphology on patient outcomes. Purpose: To determine the effect of rotator cuff tear pattern (crescent, U-shape, L-shape) on patient-reported outcomes after rotator cuff repair. Study Design: Cohort study; Level of evidence, 3. Methods: Patients undergoing arthroscopic repair of known full-thickness rotator cuff tears were observed prospectively at regular intervals from baseline to 1 year. The tear pattern was classified at the time of surgery as crescent, U-shaped, or L-shaped. Primary outcome measures were the Western Ontario Rotator Cuff Index (WORC), the American Shoulder and Elbow Surgeons (ASES), and a visual analog scale (VAS) for pain. The tear pattern was evaluated as the primary predictor while controlling for variables known to affect rotator cuff outcomes. Mixed-methods regression and analysis of variance (ANOVA) were used to examine the effects of tear morphology on patient-reported outcomes after surgical repair from baseline to 1 year. Results: A total of 82 patients were included in the study (53 male, 29 female; mean age, 58 years [range, 41-75 years]). A crescent shape was the most common tear pattern (54%), followed by U-shaped (25%) and L-shaped tears (21%). There were no significant differences in outcome scores between the 3 groups at baseline. All 3 groups showed statistically significant improvement from baseline to 1 year, but analysis failed to show any predictive effect in the change in outcome scores from baseline to 1 year for the WORC, ASES, or VAS when tear pattern was the primary predictor. Further ANOVA also failed to show any significant difference in the change in outcome scores from baseline to 1 year for the WORC (P = .96), ASES (P = .71), or VAS (P = .86). Conclusion: Rotator cuff tear pattern is not a predictor of functional outcomes after arthroscopic rotator cuff repair. PMID:29623283
In Vivo Shoulder Function After Surgical Repair of a Torn Rotator Cuff
Bey, Michael J.; Peltz, Cathryn D.; Ciarelli, Kristin; Kline, Stephanie K.; Divine, George W.; van Holsbeeck, Marnix; Muh, Stephanie; Kolowich, Patricia A.; Lock, Terrence R.; Moutzouros, Vasilios
2015-01-01
Background Surgical repair of a torn rotator cuff is based on the belief that repairing the tear is necessary to restore normal glenohumeral joint (GHJ) mechanics and achieve a satisfactory clinical outcome. Hypothesis Dynamic joint function is not completely restored by rotator cuff repair, thus compromising shoulder function and potentially leading to long-term disability. Study Design Controlled laboratory study and Case series; Level of evidence, 4. Methods Twenty-one rotator cuff patients and 35 control participants enrolled in the study. Biplane radiographic images were acquired bilaterally from each patient during coronal-plane abduction. Rotator cuff patients were tested at 3, 12, and 24 months after repair of a supraspinatus tendon tear. Control participants were tested once. Glenohumeral joint kinematics and joint contact patterns were accurately determined from the biplane radiographic images. Isometric shoulder strength and patient-reported outcomes were measured at each time point. Ultrasound imaging assessed rotator cuff integrity at 24 months after surgery. Results Twenty of 21 rotator cuff repairs appeared intact at 24 months after surgery. The humerus of the patients’ repaired shoulder was positioned more superiorly on the glenoid than both the patients’ contralateral shoulder and the dominant shoulder of control participants. Patient-reported outcomes improved significantly over time. Shoulder strength also increased over time, although strength deficits persisted at 24 months for most patients. Changes over time in GHJ mechanics were not detected for either the rotator cuff patients’ repaired or contralateral shoulders. Clinical outcome was associated with shoulder strength but not GHJ mechanics. Conclusion Surgical repair of an isolated supraspinatus tear may be sufficient to keep the torn rotator cuff intact and achieve satisfactory patient-reported outcomes, but GHJ mechanics and shoulder strength are not fully restored with current
Increased Upper Trapezius Muscle Stiffness in Overhead Athletes with Rotator Cuff Tendinopathy
Leong, Hio Teng; Hug, François; Fu, Siu Ngor
2016-01-01
Although excessive tension of the upper trapezius (UT) is thought to contribute to rotator cuff tendinopathy, no study examined UT tension in athletes with and without rotator cuff tendinopathy. Here we used UT shear modulus measured using ultrasound shear wave elastography as an index of muscle stiffness/tension. The aims of this study were twofold: 1) to determine whether the UT muscle shear modulus is altered in athletes with rotator cuff tendinopathy compared to asymptomatic athletes, and 2) to detect optimal cut-off points of UT shear modulus in identifying athletes with rotator cuff tendinopathy. Forty-three male volleyball players (17 asymptomatic and 26 with rotator cuff tendinopathy, mean age = 22.9±3.5 years) participated in the study. UT shear modulus was quantified during active arm holding at 30° and 60° of shoulder abduction and passive arm positioning at 0°, 30° and 60° of shoulder abduction. During the active tasks, the UT shear modulus was higher in athletes with rotator cuff tendinopathy than the asymptomatic athletes (p = 0.002), regardless the arm position. During the passive tasks, athletes with rotator cuff tendinopathy exhibited a higher UT shear modulus than asymptomatic athletes only at 0° of shoulder abduction (13.0±2.5 kPa vs 10.2±1.8 kPa, p = 0.001). When considering the active task, an optimal cut-off shear modulus of 12.0 kPa at 30° of shoulder abduction (sensitivity = 0.84, specificity = 0.57, AUC = 0.757, p = 0.008) and 9.5 kPa at 60° of shoulder abduction (sensitivity = 0.88, specificity = 0.67, AUC = 0.816, p = 0.002) was detected. When considering the passive task at 0° of shoulder abduction, a cut-off of 12.2 kPa was found (sensitivity = 0.73, AUC = 0.817, p = 0.001). Findings from the present study show that monitoring passive and active UT muscle shear modulus may provide important information for the prevention/rehabilitation of rotator cuff tendinopathy. PMID:27159276
Increased Upper Trapezius Muscle Stiffness in Overhead Athletes with Rotator Cuff Tendinopathy.
Leong, Hio Teng; Hug, François; Fu, Siu Ngor
2016-01-01
Although excessive tension of the upper trapezius (UT) is thought to contribute to rotator cuff tendinopathy, no study examined UT tension in athletes with and without rotator cuff tendinopathy. Here we used UT shear modulus measured using ultrasound shear wave elastography as an index of muscle stiffness/tension. The aims of this study were twofold: 1) to determine whether the UT muscle shear modulus is altered in athletes with rotator cuff tendinopathy compared to asymptomatic athletes, and 2) to detect optimal cut-off points of UT shear modulus in identifying athletes with rotator cuff tendinopathy. Forty-three male volleyball players (17 asymptomatic and 26 with rotator cuff tendinopathy, mean age = 22.9±3.5 years) participated in the study. UT shear modulus was quantified during active arm holding at 30° and 60° of shoulder abduction and passive arm positioning at 0°, 30° and 60° of shoulder abduction. During the active tasks, the UT shear modulus was higher in athletes with rotator cuff tendinopathy than the asymptomatic athletes (p = 0.002), regardless the arm position. During the passive tasks, athletes with rotator cuff tendinopathy exhibited a higher UT shear modulus than asymptomatic athletes only at 0° of shoulder abduction (13.0±2.5 kPa vs 10.2±1.8 kPa, p = 0.001). When considering the active task, an optimal cut-off shear modulus of 12.0 kPa at 30° of shoulder abduction (sensitivity = 0.84, specificity = 0.57, AUC = 0.757, p = 0.008) and 9.5 kPa at 60° of shoulder abduction (sensitivity = 0.88, specificity = 0.67, AUC = 0.816, p = 0.002) was detected. When considering the passive task at 0° of shoulder abduction, a cut-off of 12.2 kPa was found (sensitivity = 0.73, AUC = 0.817, p = 0.001). Findings from the present study show that monitoring passive and active UT muscle shear modulus may provide important information for the prevention/rehabilitation of rotator cuff tendinopathy.
Giri, Subhasis K; Sil, Debasri; Narasimhulu, Girish; Flood, Hugh D; Skehan, Mark; Drumm, John
2007-06-01
To report our experience in the management of vaginal extrusion after the tension-free vaginal tape (TVT) procedure for urodynamic stress incontinence. Five patients diagnosed with vaginal extrusion after a TVT procedure performed at our institution were identified. We reviewed the patients' records retrospectively. The interval from TVT placement to diagnosis, presenting symptoms and signs, duration of symptoms, diagnostic test findings, treatment, and postoperative results were recorded. Patients were followed up for at least 12 months. From January 2001 to June 2004, a total of 166 patients underwent the TVT procedure. Of these, 5 patients (3%) were diagnosed with isolated vaginal extrusion 4 to 40 months postoperatively. No cases of urethral or bladder erosion occurred in this series. The symptoms included vaginal discharge, pain, bleeding, and dyspareunia. The eroded margin of the vaginal mucosa was trimmed, mobilized, and closed over the tape with interrupted vertical mattress sutures in a single layer using 2-0 polyglactin 910 to avoid mucosal inversion. All patients remained symptom free without any evidence of defective healing or additional extrusion at a minimal follow-up of 12 months. Primary reclosure of the vaginal mucosa over the TVT tape is an effective first-line treatment option for vaginal extrusion without compromising continence. Patients undergoing the TVT procedure should be adequately counseled about the possibility of this complication and the available treatment options.
Differences of RNA Expression in the Tendon According to Anatomic Outcomes in Rotator Cuff Repair.
Ahn, Jin-Ok; Chung, Jin-Young; Kim, Do Hoon; Im, Wooseok; Kim, Sae Hoon
2017-11-01
Despite increased understanding of the pathophysiology of rotator cuff tears and the evolution of rotator cuff repair, healing failure remains a substantial problem. The critical roles played by biological factors have been emphasized, but little is known of the implications of gene expression profile differences at the time of repair. To document the relationship between the perioperative gene expression of healed and unhealed rotator cuffs by RNA microarray analysis. Case-control study; Level of evidence, 3. Superior (supraspinatus involvement) and posterosuperior (supraspinatus and infraspinatus involvement) tears were included in the study. Samples of rotator cuff tendons were prospectively collected during rotator cuff surgery. Three samples were harvested at the tendon ends of tears from the anterior, middle (apex), and posterior parts using an arthroscopic punch. Seven patients with an unhealed rotator cuff were matched one-to-one with patients with a healed rotator cuff by sex, age, tear size, and fatty degeneration of rotator cuff muscles. mRNA microarray analysis was used to identify genetic differences between healed and unhealed rotator cuff tendons. Gene ontology and gene association files were obtained from the Gene Ontology Consortium, and the Gene Ontology system in DAVID was used to identify enhanced biological processes. Microarray analyses identified 262 genes that were differentially expressed by at least 1.5-fold between the healed and unhealed groups. Overall, in the healed group, 103 genes were significantly downregulated, and 159 were significantly upregulated. DAVID Functional Annotation Cluster analysis showed that in the healed group, the genes most upregulated were related to the G protein-coupled receptor protein signaling pathway and to the neurological system. On the other hand, the genes most downregulated were related to immune and inflammatory responses. BMP5 was the gene most upregulated in the healed group, and the majority of
Vaginitis: current microbiologic and clinical concepts.
Hill, L V; Embil, J A
1986-01-01
Infectious vaginitis occurs when the normal vaginal flora is disrupted; it may arise when saprophytes overwhelm the host immune response, when pathogenic organisms are introduced into the vagina or when changes in substrate allow an imbalance of microorganisms to develop. Examples of these types of vaginitis include the presence of chronic fungal infection in women with an inadequate cellular immune response to the yeast, the introduction of trichomonads into vaginal epithelium that has a sufficient supply of glycogen, and the alteration in bacterial flora, normally dominated by Lactobacillus spp., and its metabolites that is characteristic of "nonspecific vaginitis". The authors review microbiologic and clinical aspects of the fungal, protozoal and bacterial infections, including the interactions of bacteria thought to produce nonspecific vaginitis, that are now recognized as causing vaginitis. Other causes of vaginitis are also discussed. PMID:3510698
Vaginitis: current microbiologic and clinical concepts.
Hill, L V; Embil, J A
1986-02-15
Infectious vaginitis occurs when the normal vaginal flora is disrupted; it may arise when saprophytes overwhelm the host immune response, when pathogenic organisms are introduced into the vagina or when changes in substrate allow an imbalance of microorganisms to develop. Examples of these types of vaginitis include the presence of chronic fungal infection in women with an inadequate cellular immune response to the yeast, the introduction of trichomonads into vaginal epithelium that has a sufficient supply of glycogen, and the alteration in bacterial flora, normally dominated by Lactobacillus spp., and its metabolites that is characteristic of "nonspecific vaginitis". The authors review microbiologic and clinical aspects of the fungal, protozoal and bacterial infections, including the interactions of bacteria thought to produce nonspecific vaginitis, that are now recognized as causing vaginitis. Other causes of vaginitis are also discussed.
Tempelaere, Christine; Pierrart, Jérome; Lefèvre-Colau, Marie-Martine; Vuillemin, Valérie; Cuénod, Charles-André; Hansen, Ulrich; Mir, Olivier; Skalli, Wafa; Gregory, Thomas
2016-01-01
MRI is the standard methodology in diagnosis of rotator cuff diseases. However, many patients continue to have pain despite treatment, and MRI of a static unloaded shoulder seems insufficient for best diagnosis and treatment. This study evaluated if Dynamic MRI provides novel kinematic data that can be used to improve the understanding, diagnosis and best treatment of rotator cuff diseases. Dynamic MRI provided real-time 3D image series and was used to measure changes in the width of subacromial space, superior-inferior translation and anterior-posterior translation of the humeral head relative to the glenoid during active abduction. These measures were investigated for consistency with the rotator cuff diseases classifications from standard MRI. The study included: 4 shoulders with massive rotator cuff tears, 5 shoulders with an isolated full-thickness supraspinatus tear, 5 shoulders with tendinopathy and 6 normal shoulders. A change in the width of subacromial space greater than 4mm differentiated between rotator cuff diseases with tendon tears (massive cuff tears and supraspinatus tear) and without tears (tendinopathy) (p = 0.012). The range of the superior-inferior translation was higher in the massive cuff tears group (6.4mm) than in normals (3.4mm) (p = 0.02). The range of the anterior-posterior translation was higher in the massive cuff tears (9.2 mm) and supraspinatus tear (9.3 mm) shoulders compared to normals (3.5mm) and tendinopathy (4.8mm) shoulders (p = 0.05). The Dynamic MRI enabled a novel measure; 'Looseness', i.e. the translation of the humeral head on the glenoid during an abduction cycle. Looseness was better able at differentiating different forms of rotator cuff disease than a simple static measure of relative glenohumeral position.
Tempelaere, Christine; Pierrart, Jérome; Lefèvre-Colau, Marie-Martine; Vuillemin, Valérie; Cuénod, Charles-André; Hansen, Ulrich; Mir, Olivier; Skalli, Wafa; Gregory, Thomas
2016-01-01
Background MRI is the standard methodology in diagnosis of rotator cuff diseases. However, many patients continue to have pain despite treatment, and MRI of a static unloaded shoulder seems insufficient for best diagnosis and treatment. This study evaluated if Dynamic MRI provides novel kinematic data that can be used to improve the understanding, diagnosis and best treatment of rotator cuff diseases. Methods Dynamic MRI provided real-time 3D image series and was used to measure changes in the width of subacromial space, superior-inferior translation and anterior-posterior translation of the humeral head relative to the glenoid during active abduction. These measures were investigated for consistency with the rotator cuff diseases classifications from standard MRI. Results The study included: 4 shoulders with massive rotator cuff tears, 5 shoulders with an isolated full-thickness supraspinatus tear, 5 shoulders with tendinopathy and 6 normal shoulders. A change in the width of subacromial space greater than 4mm differentiated between rotator cuff diseases with tendon tears (massive cuff tears and supraspinatus tear) and without tears (tendinopathy) (p = 0.012). The range of the superior-inferior translation was higher in the massive cuff tears group (6.4mm) than in normals (3.4mm) (p = 0.02). The range of the anterior-posterior translation was higher in the massive cuff tears (9.2 mm) and supraspinatus tear (9.3 mm) shoulders compared to normals (3.5mm) and tendinopathy (4.8mm) shoulders (p = 0.05). Conclusion The Dynamic MRI enabled a novel measure; ‘Looseness’, i.e. the translation of the humeral head on the glenoid during an abduction cycle. Looseness was better able at differentiating different forms of rotator cuff disease than a simple static measure of relative glenohumeral position. PMID:27434235
Effect of Vaginal or Systemic Estrogen on Dynamics of Collagen Assembly in the Rat Vaginal Wall1
Montoya, T. Ignacio; Maldonado, P. Antonio; Acevedo, Jesus F.; Word, R. Ann
2014-01-01
ABSTRACT The objective of this study was to compare the effects of systemic and local estrogen treatment on collagen assembly and biomechanical properties of the vaginal wall. Ovariectomized nulliparous rats were treated with estradiol or conjugated equine estrogens (CEEs) either systemically, vaginal CEE, or vaginal placebo cream for 4 wk. Low-dose local CEE treatment resulted in increased vaginal epithelial thickness and significant vaginal growth without uterine hyperplasia. Furthermore, vaginal wall distensibility increased without compromise of maximal force at failure. Systemic estradiol resulted in modest increases in collagen type I with no change in collagen type III mRNA. Low-dose vaginal treatment, however, resulted in dramatic increases in both collagen subtypes whereas moderate and high dose local therapies were less effective. Consistent with the mRNA results, low-dose vaginal estrogen resulted in increased total and cross-linked collagen content. The inverse relationship between vaginal dose and collagen expression may be explained in part by progressive downregulation of estrogen receptor-alpha mRNA with increasing estrogen dose. We conclude that, in this menopausal rat model, local estrogen treatment increased total and cross-linked collagen content and markedly stimulated collagen mRNA expression in an inverse dose-effect relationship. High-dose vaginal estrogen resulted in downregulation of estrogen receptor-alpha and loss of estrogen-induced increases in vaginal collagen. These results may have important clinical implications regarding the use of local vaginal estrogen therapy and its role as an adjunctive treatment in women with loss of vaginal support. PMID:25537371
Hu, Kai-tao; Zheng, Jin-xin; Yu, Zhi-jian; Chen, Zhong; Cheng, Hang; Pan, Wei-guang; Yang, Wei-zhi; Wang, Hong-yan; Deng, Qi-wen; Zeng, Zhong-ming
2015-04-01
Sucrose gel was used to treat bacterial vaginosis in a phase III clinical trial. However, the changes of vaginal flora after treatment were only examined by Nugent score in that clinical trial, While the vaginal microbiota of rhesus macaques is characterized by anaerobic, Gram-negative bacteria, few lactobacilli, and pH levels above 4.6, similar to the microbiota of patients with bacterial vaginosis. This study is aimed to investigate the change of the vaginal microbiota of rehsus macaques after topical use of sucrose gel to reveal more precisely the bacterial population shift after the topical application of sucrose gel. Sixteen rhesus macaques were treated with 0.5 g sucrose gel vaginally and three with 0.5 g of placebo gel. Vaginal swabs were collected daily following treatment. Vaginal pH levels and Nugent scores were recorded. The composition of the vaginal micotbiota was tested by V3∼V4 16S rDNA metagenomic sequencing. Dynamic changes in the Lactobacillus genus were analyzed by qPCR. The vaginal microbiota of rhesus macaques are dominated by anaerobic Gram-negative bacteria, with few lactobacilli and high pH levels above 4.6. After five days' treatment with topical sucrose gel, the component percentage of Lactobacillus in vaginal microbiota increased from 1.31% to 81.59%, while the component percentage of Porphyromonas decreased from 18.60% to 0.43%, Sneathia decreased from 15.09% to 0.89%, Mobiluncus decreased from 8.23% to 0.12%, etc.. The average vaginal pH values of 16 rhesus macaques of the sucrose gel group decreased from 5.4 to 3.89. There were no significant changes in microbiota and vaginal pH observed in the placebo group. Rhesus macaques can be used as animal models of bacterial vaginosis to develop drugs and test treatment efficacy. Furthermore, the topical application of sucrose gel induced the shifting of vaginal flora of rhesus macaques from a BV kind of flora to a lactobacilli-dominating flora. Copyright © 2015 The Authors. Published by
Redler, Lauren H.; Byram, Ian R.; Luchetti, Timothy J.; Tsui, Ying Lai; Moen, Todd C.; Gardner, Thomas R.; Ahmad, Christopher S.
2014-01-01
Background: Redundancies in the rotator cuff tissue, commonly referred to as “dog ear” deformities, are frequently encountered during rotator cuff repair. Knowledge of how these deformities are created and their impact on rotator cuff footprint restoration is limited. Purpose: The goals of this study were to assess the impact of tear size and repair method on the creation and management of dog ear deformities in a human cadaveric model. Study Design: Controlled laboratory study. Methods: Crescent-shaped tears were systematically created in the supraspinatus tendon of 7 cadaveric shoulders with increasing medial to lateral widths (0.5, 1.0, and 1.5 cm). Repair of the 1.5-cm tear was performed on each shoulder with 3 methods in a randomized order: suture bridge, double-row repair with 2-mm fiber tape, and fiber tape with peripheral No. 2 nonabsorbable looped sutures. Resulting dog ear deformities were injected with an acrylic resin mixture, digitized 3-dimensionally (3D), and photographed perpendicular to the footprint with calibration. The volume, height, and width of the rotator cuff tissue not in contact with the greater tuberosity footprint were calculated using the volume injected, 3D reconstructions, and calibrated photographs. Comparisons were made between tear size, dog ear measurement technique, and repair method utilizing 2-way analysis of variance and Student-Newman-Keuls multiple-comparison tests. Results: Utilizing 3D digitized and injection-derived volumes and dimensions, anterior dog ear volume, height, and width were significantly smaller for rotator cuff repair with peripheral looped sutures compared with a suture bridge (P < .05) or double-row repair with 2-mm fiber tape alone (P < .05). Similarly, posterior height and width were significantly smaller for repair with looped peripheral sutures compared with a suture bridge (P < .05). Dog ear volumes and heights trended larger for the 1.5-cm tear, but this was not statistically significant
Ottesen, Marianne; Sørensen, Mette; Rasmussen, Yvonne; Smidt-Jensen, Steen; Kehlet, Henrik; Ottesen, Bent
2002-02-01
Our aim was to describe the need for postoperative hospitalization after vaginal surgery for utero-vaginal prolapse with well-defined charts for postoperative care. A prospective, descriptive study. Consecutive women admitted for first-time vaginal surgery for utero-vaginal prolapse at a public university hospital in Copenhagen, Denmark, underwent surgery and postoperative care in a fast track setting from September 15, 1999 to June 15 2000. A multimodal rehabilitation model with emphasis on information, standardized general anesthesia, reduced surgical distress, optimized pain-relief, early oral nutrition and ambulation, minimal use of indwelling catheter and vaginal packing. Postoperative hospital stay, complications, re-admission, success rate, patients' satisfaction and acceptability. Forty-one women with a median age of 69 years (range, 44-88 years) were included. All underwent anterior and/or posterior vaginal repair. Nineteen (46.3%) underwent vaginal hysterectomy, and eight (19.5%) underwent the Manchester procedure. Postoperative hospital stay was median 24 hr. Only three (7.3%) were discharged later than 48 hr. No re-admissions occurred. The most frequent complications were urinary retention exceeding 450 ml, and urinary tract infection (12.2%, and 9.8%, respectively). Short-term success rate was 97.6%. Patients' satisfaction rates were 85.4-95.1%. The median score of acceptability was 10 on a 0-10 points scale. The need for postoperative hospitalization was median 24 hr after vaginal surgery in a fast track setting, independently of the complexity of the procedure performed. Short-term success rate, satisfaction rates, and acceptability were all excellent. Follow up has been established to evaluate long-term success rates and recurrence.
Ito, Takuji; Bai, Tao; Tanaka, Tetsuji; Yoshida, Kenji; Ueyama, Takashi; Miyajima, Masayasu; Negishi, Takayuki; Kawasaki, Takahiko; Takamatsu, Hyota; Kikutani, Hitoshi; Kumanogoh, Atsushi; Yukawa, Kazunori
2015-02-01
The opening of the mouse vaginal cavity to the skin is a postnatal tissue remodeling process that occurs at approximately five weeks of age for the completion of female genital tract maturation at puberty. The tissue remodeling process is primarily composed of a hormonally triggered apoptotic process predominantly occurring in the epithelium of the distal section of the vaginal cavity. However, the detailed mechanism underlying the apoptotic induction remains to be elucidated. In the present study, it was observed that the majority of BALB/c mice lacking the class 4 semaphorin, semaphorin 4D (Sema4D), developed imperforate vagina and hydrometrocolpos resulting in a perpetually unopened vaginal cavity regardless of a normal estrogen level comparable with that in wild‑type (WT) mice. Administration of β‑estradiol to infant Sema4D‑deficient (Sema4D‑/‑) mice did not induce precocious vaginal opening, which was observed in WT mice subjected to the same β‑estradiol administration, excluding the possibility that the closed vaginal phenotype was due to insufficient estrogen secretion at the time of vaginal opening. In order to assess the role of Sema4D in the postnatal vaginal tissue remodeling process, the expression of Sema4D and its receptor, plexin‑B1, was examined as well as the level of apoptosis in the vaginal epithelia of five‑week‑old WT and Sema4D‑/‑ mice. Immunohistochemical analyses confirmed the localization of Sema4D and plexin‑B1 in the mouse vaginal epithelia. Terminal deoxynucleotidyl transferase dUTP nick end labeling assay and immunohistochemistry detecting activated caspase‑3 revealed significantly fewer apoptotic cells in situ in the vaginal mucosa of five‑week‑old Sema4D‑/‑ mice compared with WT mice. The addition of recombinant Sema4D to Sema4D‑/‑ vaginal epithelial cells in culture significantly enhanced apoptosis of the vaginal epithelial cells, demonstrating the apoptosis‑inducing activity of Sema4D. The
ITO, TAKUJI; BAI, TAO; TANAKA, TETSUJI; YOSHIDA, KENJI; UEYAMA, TAKASHI; MIYAJIMA, MASAYASU; NEGISHI, TAKAYUKI; KAWASAKI, TAKAHIKO; TAKAMATSU, HYOTA; KIKUTANI, HITOSHI; KUMANOGOH, ATSUSHI; YUKAWA, KAZUNORI
2015-01-01
The opening of the mouse vaginal cavity to the skin is a postnatal tissue remodeling process that occurs at approximately five weeks of age for the completion of female genital tract maturation at puberty. The tissue remodeling process is primarily composed of a hormonally triggered apoptotic process predominantly occurring in the epithelium of the distal section of the vaginal cavity. However, the detailed mechanism underlying the apoptotic induction remains to be elucidated. In the present study, it was observed that the majority of BALB/c mice lacking the class 4 semaphorin, semaphorin 4D (Sema4D), developed imperforate vagina and hydrometrocolpos resulting in a perpetually unopened vaginal cavity regardless of a normal estrogen level comparable with that in wild-type (WT) mice. Administration of β-estradiol to infant Sema4D-deficient (Sema4D−/−) mice did not induce precocious vaginal opening, which was observed in WT mice subjected to the same β-estradiol administration, excluding the possibility that the closed vaginal phenotype was due to insufficient estrogen secretion at the time of vaginal opening. In order to assess the role of Sema4D in the postnatal vaginal tissue remodeling process, the expression of Sema4D and its receptor, plexin-B1, was examined as well as the level of apoptosis in the vaginal epithelia of five-week-old WT and Sema4D−/− mice. Immunohistochemical analyses confirmed the localization of Sema4D and plexin-B1 in the mouse vaginal epithelia. Terminal deoxynucleotidyl transferase dUTP nick end labeling assay and immunohistochemistry detecting activated caspase-3 revealed significantly fewer apoptotic cells in situ in the vaginal mucosa of five-week-old Sema4D−/− mice compared with WT mice. The addition of recombinant Sema4D to Sema4D−/− vaginal epithelial cells in culture significantly enhanced apoptosis of the vaginal epithelial cells, demonstrating the apoptosis-inducing activity of Sema4D. The experimental reduction of
[A design and study of a novel electronic device for cuff-pressure monitoring].
Wang, Shupeng; Li, Wei; Li, Wen; Song, Dejing; Chen, Desheng; Duan, Jun; Li, Chen; Li, Gang
2017-06-01
To design a novel electronic device for measuring the pressure in the cuff of the artificial airway; and to study the advantage of this device on continuous and intermittent cuff pressure monitoring. (1) a portable electronic device for cuff pressure measurement was invented, which could turn pressure signal into electrical signal through a pressure transducer. Meantime, it was possible to avoid pressure leak from the joint and the inside of the apparatus by modified Luer taper and sophisticated design. If the cuff pressure was out of the normal range, the apparatus could release a sound and light alarm. (2) Six traditional mechanical manometers were used to determine the cuff pressure in 6 tracheal tubes. The cuff pressure was maintain at 30 cmH 2 O (1 cmH 2 O = 0.098 kPa) by the manometer first, and repeated every 30 seconds for 4 times. (3) Study of continuous cuff pressure monitoring: We used a random number generator to randomize 6 tracheal tubes, 6 mechanical manometers and 6 our products by number 1-6, which has the same number of a group. Every group was further randomized into two balanced groups, one group used the mechanical manometer first, and the other used our product first. The baseline pressure was 30 cmH 2 O, measurement was performed every 4 hours for 6 times. When traditional mechanical manometer was used for cuff pressure monitoring, cuff pressure was decreased by an average of 2.9 cmH 2 O for each measurement (F = 728.2, P = 0.000). In study of continually monitoring, at each monitoring point, the pressure measured by electronic manometer was higher than the mechanical manometer. All the pressures measured by mechanical manometer were dropped below 20 cmH 2 O at 8th hour, and there was no pressure decrease below 20 cmH 2 O measured by electronic manometer in 24 hours by contrast. In study of intermittent monitoring, the same result was found. The pressure was dropped significantly with time when measured by mechanical manometer (F = 61.795, P
Rotator Cuff Strength Ratio and Injury in Glovebox Workers
DOE Office of Scientific and Technical Information (OSTI.GOV)
Weaver, Amelia M.
Rotator cuff integrity is critical to shoulder health. Due to the high workload imposed upon the shoulder while working in an industrial glovebox, this study investigated the strength ratio of the rotator cuff muscles in glovebox workers and compared this ratio to the healthy norm. Descriptive statistics were collected using a short questionnaire. Handheld dynamometry was used to quantify the ratio of forces produced in the motions of shoulder internal and external rotation. Results showed this population to have shoulder strength ratios that were significantly different from the healthy norm. The deviation from the normal ratio demonstrates the need formore » solutions designed to reduce the workload on the rotator cuff musculature of glovebox workers in order to improve health and safety. Assessment of strength ratios can be used to screen for risk of symptom development.« less
Classification of full-thickness rotator cuff lesions: a review
Lädermann, Alexandre; Burkhart, Stephen S.; Hoffmeyer, Pierre; Neyton, Lionel; Collin, Philippe; Yates, Evan; Denard, Patrick J.
2016-01-01
Rotator cuff lesions (RCL) have considerable variability in location, tear pattern, functional impairment, and repairability. Historical classifications for differentiating these lesions have been based upon factors such as the size and shape of the tear, and the degree of atrophy and fatty infiltration. Additional recent descriptions include bipolar rotator cuff insufficiency, ‘Fosbury flop tears’, and musculotendinous lesions. Recommended treatment is based on the location of the lesion, patient factors and associated pathology, and often includes personal experience and data from case series. Development of a more comprehensive classification which integrates historical and newer descriptions of RCLs may help to guide treatment further. Cite this article: Lädermann A, Burkhart SS, Hoffmeyer P, et al. Classification of full thickness rotator cuff lesions: a review. EFORT Open Rev 2016;1:420-430. DOI: 10.1302/2058-5241.1.160005. PMID:28461921
Demba, Edward; Morison, Linda; van der Loeff, Maarten Schim; Awasana, Akum A; Gooding, Euphemia; Bailey, Robin; Mayaud, Philippe; West, Beryl
2005-01-01
Background Bacterial vaginosis (BV) – a syndrome characterised by a shift in vaginal flora – appears to be particularly common in sub-Saharan Africa, but little is known of the pattern of vaginal flora associated with BV in Africa. We conducted a study aimed at determining the prevalence of BV and patterns of BV-associated vaginal micro-flora among women with vaginal discharge syndrome (VDS) in The Gambia, West Africa. Methods We enrolled 227 women with VDS from a large genito-urinary medicine clinic in Fajara, The Gambia. BV was diagnosed by the Nugent's score and Amsel's clinical criteria. Vaginal swabs were collected for T vaginalis and vaginal flora microscopy, and for Lactobacillus spp, aerobic organisms, Candida spp and BV-associated bacteria (Gardnerella vaginalis, anaerobic bacteria, and Mycoplasma spp) cultures; and cervical swabs were collected for N gonorrhoeae culture and C trachomatis PCR. Sera were tested for HIV-1 and HIV-2 antibodies. Sexual health history including details on sexual hygiene were obtained by standardised questionnaire. Results BV prevalence was 47.6% by Nugent's score and 30.8% by Amsel's clinical criteria. Lactobacillus spp were isolated in 37.8% of women, and 70% of the isolates were hydrogen-peroxide (H202)-producing strains. Prevalence of BV-associated bacteria were: G vaginalis 44.4%; Bacteroides 16.7%; Prevotella 15.2%; Peptostretococcus 1.5%; Mobiluncus 0%; other anaerobes 3.1%; and Mycoplasma hominis 21.4%. BV was positively associated with isolation of G vaginalis (odds-ratio [OR] 19.42, 95%CI 7.91 – 47.6) and anaerobes (P = 0.001 [OR] could not be calculated), but not with M hominis. BV was negatively associated with presence of Lactobacillus (OR 0.07, 95%CI 0.03 – 0.15), and H2O2-producing lactobacilli (OR 0.12, 95% CI 0.05 – 0.28). Presence of H2O2-producing lactobacilli was associated with significantly lower prevalence of G vaginalis, anaerobes and C trachomatis. HIV prevalence was 12.8%. Overall, there was
Chung, Seok Won; Oh, Joo Han; Gong, Hyun Sik; Kim, Joon Yub; Kim, Sae Hoon
2011-10-01
The prognostic factors associated with structural outcome after arthroscopic rotator cuff repair have not yet been fully determined. The hypothesis of this study was that bone mineral density (BMD) is an important prognostic factor affecting rotator cuff healing after arthroscopic cuff repair. Cohort study; Level of evidence, 3. Among 408 patients who underwent arthroscopic repair for full-thickness rotator cuff tear between January 2004 and July 2008, 272 patients were included whose postoperative cuff integrity was verified by computed tomography arthrography (CTA) or ultrasonography (USG) and simultaneously who were evaluated by various functional outcome instruments. The mean age at the time of operation was 59.5 ± 7.9 years. Postoperative CTA or USG was performed at a mean 13.0 ± 5.1 months after surgery, and the mean follow-up period was 37.2 ± 10.0 months (range, 24-65 months). The clinical, structural, and surgery-related factors affecting cuff integrity including BMD were analyzed using both univariate and multivariate analysis. Evaluation of postoperative cuff integrity was performed by musculoskeletal radiologists who were unaware of the present study. The failure rate of rotator cuff healing was 22.8% (62 of 272). The failure rate was significantly higher in patients with lower BMD (P < .001); older age (P < .001); female gender (P = .03); larger tear size (P < .001); higher grade of fatty infiltration (FI) of the supraspinatus, infraspinatus, and subscapularis (all P < .001); diabetes mellitus (P = .02); shorter acromiohumeral distance (P < .001); and associated biceps procedure (P < .001). However, in the multivariate analysis, only BMD (P = .001), FI of the infraspinatus (P = .01), and the amount of retraction (P = .03) showed a significant relationship with cuff healing failure following arthroscopic rotator cuff repair. Bone mineral density, as well as FI of the infraspinatus and amount of retraction, was an independent determining factor
Heterogeneity of Vaginal Microbial Communities within Individuals▿ #
Kim, Tae Kyung; Thomas, Susan M.; Ho, Mengfei; Sharma, Shobha; Reich, Claudia I.; Frank, Jeremy A.; Yeater, Kathleen M.; Biggs, Diana R.; Nakamura, Noriko; Stumpf, Rebecca; Leigh, Steven R.; Tapping, Richard I.; Blanke, Steven R.; Slauch, James M.; Gaskins, H. Rex; Weisbaum, Jon S.; Olsen, Gary J.; Hoyer, Lois L.; Wilson, Brenda A.
2009-01-01
Recent culture-independent studies have revealed that a healthy vaginal ecosystem harbors a surprisingly complex assemblage of microorganisms. However, the spatial distribution and composition of vaginal microbial populations have not been investigated using molecular methods. Here, we evaluated site-specific microbial composition within the vaginal ecosystem and examined the influence of sampling technique in detection of the vaginal microbiota. 16S rRNA gene clone libraries were prepared from samples obtained from different locations (cervix, fornix, outer vaginal canal) and by different methods (swabbing, scraping, lavaging) from the vaginal tracts of eight clinically healthy, asymptomatic women. The data reveal that the vaginal microbiota is not homogenous throughout the vaginal tract but differs significantly within an individual with regard to anatomical site and sampling method used. Thus, this study illuminates the complex structure of the vaginal ecosystem and calls for the consideration of microenvironments when sampling vaginal microbiota as a clinical predictor of vaginal health. PMID:19158255
Huang, Yongmei; Merkatz, Ruth B; Hillier, Sharon L; Roberts, Kevin; Blithe, Diana L; Sitruk-Ware, Régine; Creinin, Mitchell D
2015-01-01
A contraceptive vaginal ring (CVR) containing Nestorone® (NES) and ethinyl estradiol (EE) that is reusable for 1- year (13 cycles) is under development. This study assessed effects of this investigational CVR on the incidence of vaginal infections and change in vaginal microflora. There were 120 women enrolled into a NES/EE CVR Phase III trial and a microbiology sub-study for up to 1- year of cyclic product use. Gynecological examinations were conducted at baseline, the first week of cycle 6 and last week of cycle 13 (or during early discontinuation visits). Vaginal swabs were obtained for wet mount microscopy, Gram stain and culture. The CVR was removed from the vagina at the last study visit and cultured. Semi-quantitative cultures for Lactobacillus, Gardnerella vaginalis, Enterococcus faecalis, Staphylococcus aureus, Escherichia coli, anaerobic gram negative rods (GNRs), Candida albicans and other yeasts were performed on vaginal and CVR samples. Vaginal infections were documented throughout the study. Over 1- year of use, 3.3% of subjects were clinically diagnosed with bacterial vaginosis, 15.0% with vulvovaginal candidiasis, and 0.8% with trichomoniasis. The detection rate of these three infections did not change significantly from baseline to either Cycle 6 or 13. Nugent scores remained stable. H2O2-positive Lactobacillus dominated vaginal flora with a non-significant prevalence increase from 76.7% at baseline to 82.7% at cycle 6 and 90.2% at cycle 13, and a median concentration of 107 colony forming units (cfu) per gram. Although anaerobic GNRs prevalence increased significantly, the median concentration decreased slightly (104 to 103cfu per gram). There were no significant changes in frequency or concentrations of other pathogens. High levels of agreement between vaginal and ring surface microbiota were observed. Sustained use of the NES/EE CVR did not increase the risk of vaginal infection and was not disruptive to the vaginal ecosystem. Clinical
Huang, Yongmei; Merkatz, Ruth B.; Hillier, Sharon L.; Roberts, Kevin; Blithe, Diana L.; Sitruk-Ware, Régine; Creinin, Mitchell D.
2015-01-01
Background A contraceptive vaginal ring (CVR) containing Nestorone® (NES) and ethinyl estradiol (EE) that is reusable for 1- year (13 cycles) is under development. This study assessed effects of this investigational CVR on the incidence of vaginal infections and change in vaginal microflora. Methods There were 120 women enrolled into a NES/EE CVR Phase III trial and a microbiology sub-study for up to 1- year of cyclic product use. Gynecological examinations were conducted at baseline, the first week of cycle 6 and last week of cycle 13 (or during early discontinuation visits). Vaginal swabs were obtained for wet mount microscopy, Gram stain and culture. The CVR was removed from the vagina at the last study visit and cultured. Semi-quantitative cultures for Lactobacillus, Gardnerella vaginalis, Enterococcus faecalis, Staphylococcus aureus, Escherichia coli, anaerobic gram negative rods (GNRs), Candida albicans and other yeasts were performed on vaginal and CVR samples. Vaginal infections were documented throughout the study. Results Over 1- year of use, 3.3% of subjects were clinically diagnosed with bacterial vaginosis, 15.0% with vulvovaginal candidiasis, and 0.8% with trichomoniasis. The detection rate of these three infections did not change significantly from baseline to either Cycle 6 or 13. Nugent scores remained stable. H2O2-positive Lactobacillus dominated vaginal flora with a non-significant prevalence increase from 76.7% at baseline to 82.7% at cycle 6 and 90.2% at cycle 13, and a median concentration of 107 colony forming units (cfu) per gram. Although anaerobic GNRs prevalence increased significantly, the median concentration decreased slightly (104 to 103cfu per gram). There were no significant changes in frequency or concentrations of other pathogens. High levels of agreement between vaginal and ring surface microbiota were observed. Conclusion Sustained use of the NES/EE CVR did not increase the risk of vaginal infection and was not disruptive to
Radiographic progression of arthritic changes in shoulders with degenerative rotator cuff tears.
Chalmers, Peter N; Salazar, Dane H; Steger-May, Karen; Chamberlain, Aaron M; Stobbs-Cucchi, Georgia; Yamaguchi, Ken; Keener, Jay D
2016-11-01
Very little longitudinal information has been available regarding the relationship of cuff tears and arthritis. The purpose of this study was to determine the midterm risk of and risk factors for rotator cuff tear arthropathy progression in a cohort of subjects with an asymptomatic rotator cuff tear. Baseline (visit 1), 5-year (visit 2), and most recent follow-up (visit 3) radiographs were reviewed in a cohort of 105 subjects enrolled for longitudinal surveillance of asymptomatic degenerative rotator cuff tears and 33 controls. The radiographs were assessed in a blinded, randomized fashion by 3 observers who graded glenohumeral arthritic changes using the Hamada scores, Samilson-Prieto (SPO) scores, and acromiohumeral interval (AHI). Osteoarthritis (SPO classification), cuff tear arthropathy (Hamada classification), and AHI progressed between visits 1 and 3 (median, 8 years; P < .001 in all cases). SPO progression was not significantly different for partial- vs. full-thickness vs. control baseline tear types (P = .19). Both full-thickness and partial-thickness tears had greater progression in Hamada scores than controls did in the first 5 years of follow-up (P = .02 and P = .03, respectively), but scores did not differ between partial- and full-thickness tears. Tears with and without enlargement did not differ in progression in SPO grade, Hamada grade, or AHI. Glenohumeral arthritic changes progress significantly but remain minimal within an 8-year period in early to moderate degenerative cuff disease. Whereas the presence of a rotator cuff tear influences progression in Hamada grade, the magnitude of radiographic progression is not influenced by tear severity or enlargement at midterm time points. Copyright © 2016 Journal of Shoulder and Elbow Surgery Board of Trustees. Published by Elsevier Inc. All rights reserved.
The prevalence of rotator cuff tears: is the contralateral shoulder at risk?
Liem, Dennis; Buschmann, Vera Elisa; Schmidt, Carolin; Gosheger, Georg; Vogler, Tim; Schulte, Tobias L; Balke, Maurice
2014-04-01
Rotator cuff tears are a common cause of pain and disability of the shoulder. Information on the prevalence and identification of potential risk factors could help in early detection of rotator cuff tears and improve treatment outcome. Patients treated for a symptomatic rotator cuff tear on one side have a higher prevalence of rotator cuff tears and decreased shoulder function on the contralateral side compared with an age- and sex-matched group of healthy individuals. Case control study; Level of evidence, 3. One group consisted of 55 patients who had been arthroscopically treated on one shoulder for rotator cuff tear (tear group). In this group, the nonoperated contralateral shoulder was examined. For comparison, the matching shoulder in a control group consisting of 55 subjectively healthy individuals matched by age (±1 year) and sex to the tear group was included. Diagnosis of a rotator cuff tear was made by ultrasound. Outcomes were measured using the Constant score. The prevalence of supraspinatus tears was significantly higher (P < .0001) in the tear group (67.3%) compared with the control group (11.0%). The Constant score for the activities of daily living subscale, however, was significantly lower (18.4) in the tear group compared with the control group (19.9; P = .012). No other subcategory score nor the overall score showed a significant difference. There was a significantly higher tear prevalence in the tear group of patients aged between 50 and 59 years (P < .001) and 60 and 69 years (P = .004). No tear was diagnosed in the control group in individuals younger than 60 years. Patients treated for partial and full-thickness rotator cuff tears have a significantly higher risk of having a tear on the contralateral side and have noticeable deficits in their shoulder function regarding activities of daily living even if the tear is otherwise asymptomatic.
Early versus delayed rehabilitation following arthroscopic rotator cuff repair: A systematic review.
Gallagher, Brian P; Bishop, Meghan E; Tjoumakaris, Fotios P; Freedman, Kevin B
2015-05-01
Early passive range of motion (ROM) following arthroscopic cuff repair is thought to decrease postoperative stiffness and improve functionality. However, early aggressive rehabilitation may compromise repair integrity. Our purpose was to perform a systematic review to determine if there are differences between early and delayed rehabilitation after arthroscopic rotator cuff repair in terms of clinical outcomes and healing. We performed a literature search with the terms 'arthroscopic rotator cuff', 'immobilization', 'early', 'delayed', 'late', and 'rehabilitation' using PubMed, Cochrane Central Register of Controlled Trials, and EMBASE. Selection criteria included: level I/II evidence ≤ 6 months in duration, comparing early versus delayed rehabilitation following arthroscopic repair. Data regarding demographics, sample sizes, duration, cuff pathology, surgery, rehabilitation, functional outcomes, pain, ROM and anatomic assessment of healing were analyzed. PRIMSA criteria were followed. We identified six articles matching our criteria. Three reported significantly increased functional scores within the first 3-6 months with early rehabilitation compared to the delayed group, only one of which continued to observe a difference at a final follow-up of 15 months. Four articles showed improved ROM in the first 3-6 months post-operatively with early rehabilitation. One noted transient differences in pain scores. Only one study noted significant differences in ROM at final follow-up. No study reported any significant difference in rates of rotator cuff re-tear. However, two studies noted a trend towards increased re-tear with early rehabilitation that did not reach significance. This was more pronounced in studies including medium-large tears. Early rehabilitation after arthroscopic cuff repair is associated with some initial improvements in ROM and function. Ultimately, similar clinical and anatomical outcomes between groups existed at 1 year. While there was no
Surgical removal of a large vaginal calculus formed after a tension-free vaginal tape procedure.
Zilberlicht, Ariel; Feiner, Benjamin; Haya, Nir; Auslender, Ron; Abramov, Yoram
2016-11-01
Vaginal calculus is a rare disorder which has been reported in association with urethral diverticulum, urogenital sinus anomaly, bladder exstrophy and the tension-free vaginal tape (TVT) procedure. We report a 42-year-old woman who presented with persistent, intractable urinary tract infection (UTI) following a TVT procedure. Cystoscopy demonstrated an eroded tape with the formation of a bladder calculus, and the patient underwent laser cystolithotripsy and cystoscopic resection of the tape. Following this procedure, her UTI completely resolved and she remained asymptomatic for several years. Seven years later she presented with a solid vaginal mass. Pelvic examination followed by transvaginal ultrasonography and magnetic resonance imaging demonstrated a large vaginal calculus located at the lower third of the anterior vaginal wall adjacent to the bladder neck. This video presents the transvaginal excision and removal of the vaginal calculus.
The greater tuberosity angle: a new predictor for rotator cuff tear.
Cunningham, Gregory; Nicodème-Paulin, Emilie; Smith, Margaret M; Holzer, Nicolas; Cass, Benjamin; Young, Allan A
2018-04-24
The implication of scapular morphology in rotator cuff tears has been extensively studied. However, the role of the greater tuberosity (GT) should be of equal importance. The aim of this study was to propose a new radiographic marker, the GT angle (GTA), which measures the position of the GT in relation to the center of rotation of the humeral head. The hypothesis was that a higher angle value would be associated with a higher likelihood in detecting a rotator cuff tear. During 1 year, patients were prospectively recruited from a single institution specialized shoulder clinic in 2 different groups. The patient group consisted of individuals with a degenerative rotator cuff tear involving at least the supraspinatus. The control group consisted of individuals with no rotator cuff pathology. Individuals in both groups with congenital, post-traumatic, or degenerative alterations of the proximal humerus were excluded. The GTA was measured on an anteroposterior shoulder x-ray image with the arm in neutral rotation by 3 observers at 2 different times. The study recruited 71 patients (33 patients, 38 controls). Mean GTA value was 72.5° (range, 67.6°-79.2°) in patients and 65.2° (range, 55.8°-70.5°) for controls (P <.001). A value above 70° resulted in 93-fold higher odds of detecting a rotator cuff tear (P <.001). Interobserver and intraobserver reliability were high. GT morphology is implicated in rotator cuff tears. The GTA is a reliable radiographic marker, with more than 70° being highly predictive in detecting such lesions. Copyright © 2018 Journal of Shoulder and Elbow Surgery Board of Trustees. All rights reserved.
Genetic and Familial Predisposition to Rotator Cuff Disease: A Systematic Review
Dabija, Dominique I.; Gao, Chan; Edwards, Todd L; Kuhn, John E.; Jain, Nitin B.
2017-01-01
Background Rotator cuff disease is a common disorder leading to shoulder pain and loss of function. Its etiology in atraumatic cases is uncertain and likely extends beyond repetitive micro-trauma or overuse. Our objective was to determine whether there is a genetic or familial predisposition to rotator cuff disease. Methods A literature search of PubMed and EMBASE databases identified 251 citations. After reviewing the titles, abstracts, and full articles, seven met our inclusion/exclusion criteria. Results Four studies assessed familial predisposition to rotator cuff disease. One of these demonstrated that siblings of an individual with a rotator cuff tear were more likely to develop a full-thickness tear and more likely to be symptomatic. A five-year follow-up showed that the relative risks were increased for the siblings to have a full-thickness tear, for a tear to progress in size, and for being symptomatic. Another study demonstrated that a significantly higher number of individuals with tears had family members with a history of tears or surgery than those without tears. The other three studies investigated whether a genetic predisposition to rotator cuff disease exists and found significant association of haplotypes in DEFB1, FGFR1, FGFR3, ESRRB, and FGF10, and two single nucleotide polymorphisms within SAP30BP and SASH1. Conclusion Prior studies provide preliminary evidence for genetic and familial predisposition to rotator cuff disease. However, there is a lack of large genome-wide studies that can provide more definitive information and guide early detection of individuals at risk, prophylactic rehabilitation, and potential gene therapies and regenerative medicine interventions. Level of Evidence Systematic Review PMID:28162885
Vaginal Calculus in a Woman With Mixed Urinary Incontinence and Vaginal Mesh Exposure.
Winkelman, William D; Rabban, Joseph T; Korn, Abner P
2016-01-01
Vaginal calculi are extremely rare and are most commonly encountered in the setting of an urethrovaginal or vesicovaginal fistula. We present a case of a 72-year-old woman with mixed urinary incontinence and vaginal mesh exposure incidentally found to have a large vaginal calculus. We removed the calculus surgically and analyzed the components. Results demonstrated the presence of ammonium-magnesium phosphate hexahydrate and carbonate apatite.
Surgeon-Directed Cost Variation in Isolated Rotator Cuff Repair.
Terhune, E Bailey; Cannamela, Peter C; Johnson, Jared S; Saad, Charles D; Barnes, John; Silbernagel, Janette; Faciszewski, Thomas; Shea, Kevin G
2016-12-01
As value becomes a larger component of heath care decision making, cost data can be evaluated for regional and physician variation. Value is determined by outcome divided by cost, and reducing cost increases value for patients. "Third-party spend" items are individual selections by surgeons used to perform procedures. Cost data for third-party spend items provide surgeons and hospitals with important information regarding care value, potential cost-saving opportunities, and the total cost of ownership of specific clinical decisions. To perform a cost review of isolated rotator cuff repair within a regional 7-hospital system and to document procedure cost variation among operating surgeons. Economic and decision analysis; Level of evidence, 4. Current Procedural Terminology (CPT) codes were used to retrospectively identify subjects who received an isolated rotator cuff repair within a 7-hospital system. Cost data were collected for clinically sensitive third-party spend items and divided into 4 cost groups: (1) suture anchors, (2) suture-passing devices and needles, (3) sutures used for cuff repair, and (4) disposable tools or instruments. A total of 62 isolated rotator cuff repairs were performed by 17 surgeons over a 13-month period. The total cost per case for clinically sensitive third-party spend items (in 2015 US dollars) ranged from $293 to $3752 (mean, $1826). Four surgeons had a mean procedure cost that was higher than the data set mean procedure cost. The cost of an individual suture anchor ranged from $75 to $1775 (mean, $403). One disposable suture passer was used, which cost $140. The cost of passing needles ranged from $140 to $995 (mean, $468). The cost per repair suture (used to repair cuff tears) varied from $18 to $298 (mean, $61). The mean suture (used to close wounds) cost per case was $81 (range, $0-$454). A total of 316 tools or disposable instruments were used, costing $1 to $1573 per case (mean, $624). This study demonstrates significant cost
Surgical wound dehiscence: a conceptual framework for patient assessment.
Sandy-Hodgetts, Kylie; Carville, Keryln; Leslie, Gavin D
2018-03-02
This paper presents a conceptual framework which outlines the risk factors associated with surgical wound dehiscence (SWD) as identified in the literature. The purpose for the development of the conceptual framework was to derive an evidence-based, informed understanding of factors associated with SWD, in order to inform a programme of research on the aetiology and potential risk factors of SWD. Incorporated within the patient-centric conceptual framework are patient related comorbidities, intraoperative and postoperative risk factors related to SWD. These are categorised as either 'mechanical' or 'physiological mechanisms' posited to influence these relationships. The use of the conceptual model for assessment of patients has particular clinical relevance for identification of risk and the management of patients in the pre-, intra- and postoperative period.
Muscle fibers are injured at the time of acute and chronic rotator cuff repair.
Davis, Max E; Stafford, Patrick L; Jergenson, Matthew J; Bedi, Asheesh; Mendias, Christopher L
2015-01-01
Rotator cuff tears are a common source of shoulder pain and disability. Even after surgical repair, some patients continue to have reduced function and progression of fatty degeneration. Because patients with chronic cuff tears often experience muscle shortening, it is possible that repairing the tendon to its anatomic footprint induces a stretch-induced muscle injury that could contribute to failures of the repair and perhaps ongoing pain. We hypothesized that, compared with acutely torn and repaired muscles, the stretch that is required to repair a chronically torn cuff would result in more muscle fiber damage. Specifically, we asked: (1) Is there muscle fiber damage that occurs from repair of an acutely torn rotator cuff and does it vary by location in the muscle; and (2) is the damage greater in the case of repair of a chronic injury? We used an open surgical approach to create a full-thickness rotator cuff tear in rats, and measured changes in muscle mass, length, and the number of fibers containing the membrane impermeable Evans Blue Dye after acute (1 day) or chronic (28 days) cuff tear or repair in rats. Differences between groups were tested using a one-way ANOVA followed by Tukey's post hoc sorting. Chronic tears resulted in 24% to 35% decreases in mass and a 20% decrease in length. The repair of acutely and chronically torn muscles resulted in damage to 90% of fibers in the distal portion of the muscle. In the proximal portion, no differences between the acutely torn and repaired groups and controls were observed, whereas repairing the chronically torn group resulted in injury to almost 70% of fibers. In a rat model, marked injury to muscle fibers is induced when the tendons of torn rotator cuffs are repaired to their anatomic footprint. In this animal model, we found that repair of chronically torn cuff muscles results in extensive injury throughout the muscle. Based on these findings, we posit that inducing a widespread injury at the time of surgical
Providers' Experiences with Vaginal Dilator Training for Patients with Vaginal Agenesis.
Patel, Vrunda; Hakim, Julie; Gomez-Lobo, Veronica; Amies Oelschlager, Anne-Marie
2018-02-01
To examine providers' experiences with vaginal dilator training for patients with vaginal agenesis. Anonymous electronic survey. Members of the North American Society for Pediatric and Adolescent Gynecology. How providers learn about vaginal dilator training, common techniques, and methods used for patient training, assessment of patient readiness, common patient complaints, issues leading to early discontinuation. There were a total of 55 completed survey responses of which 31 respondents (56%) had been in practice for more than 10 years. Forty-nine were gynecologists (89%), 20 had completed a fellowship in pediatric and adolescent gynecology (36%), and 6 were reproductive endocrinologists (11%). Thirty-one respondents had first learned about vaginal dilator training through lectures (56%) whereas only 9 through mentorship and fellowship (16%). According to respondents, the most common issue leading to early discontinuation was lack of patient motivation and readiness (n = 42; 76%). The most common complication was pain or discomfort (n = 45; 82%). More than half of respondents determined dilator therapy was successful when patients reported comfortable sexual intercourse (n = 30; 55%) and 65% (n = 35) did not delineate any restrictions to initiation of sexual intercourse. Most respondents (87%) requested further vaginal dilator training at either a clinical meeting (n = 26; 47%) or with a training video (n = 22; 40%). Our study in an experienced cohort of pediatric gynecology providers highlights the need for further research and training on vaginal dilation education. Copyright © 2017 North American Society for Pediatric and Adolescent Gynecology. Published by Elsevier Inc. All rights reserved.
Midterm clinical outcomes following arthroscopic transosseous rotator cuff repair
Flanagin, Brody A.; Garofalo, Raffaele; Lo, Eddie Y.; Feher, LeeAnne; Castagna, Alessandro; Qin, Huanying; Krishnan, Sumant G.
2016-01-01
Purpose: Arthroscopic transosseous (TO) rotator cuff repair has recently emerged as a new option for surgical treatment of symptomatic rotator cuff tears. Limited data is available regarding outcomes using this technique. This study evaluated midterm clinical outcomes following a novel arthroscopic TO (anchorless) rotator cuff repair technique. Materials and Methods: A consecutive series of 107 patients and 109 shoulders underwent arthroscopic TO (anchorless) rotator cuff repair for a symptomatic full-thickness tear. Pre and postoperative range of motion (ROM) was compared at an average of 11.8 months. Postoperative outcome scores were obtained at an average of 38.0 months. Statistical analysis was performed to compare pre and postoperative ROM data. Univariate analysis was performed using Student's t-test to compare the effect of other clinical characteristics on final outcome. Results: Statistically significant improvements were noted in forward flexion, external rotation and internal rotation (P < 0.0001). Average postoperative subjective shoulder value was 93.7, simple shoulder test 11.6, and American Shoulder and Elbow Surgeons (ASES) score 94.6. According to ASES scores, results for the 109 shoulders available for final follow-up were excellent in 95 (87.1%), good in 8 (7.3%), fair in 3 (2.8%), and poor in 3 (2.8%). There was no difference in ROM or outcome scores in patients who underwent a concomitant biceps procedure (tenodesis or tenotomy) compared with those who did not. Furthermore, there was no significant difference in outcome between patients who underwent either biceps tenodesis or tenotomy. Age, history of injury preceding the onset of pain, tear size, number of TO tunnels required to perform the repair, and presence of fatty infiltration did not correlate with postoperative ROM or subjective outcome measures at final follow-up. Two complications and four failures were noted. Conclusions: Arthroscopic TO rotator cuff repair technique leads to
Fritz, M; Rinaldi, G
2008-01-01
Systolic blood pressure (SBP) is still measured in rats by the tail-cuff method, allowing readings when pulse/flow disappears during cuff inflation and reappears during deflation, separated by a compression interval. Although cuff deflation is habitually used to estimate SBP, we found cuff deflation-cuff inflation pressure to be usually negative, indicating that cuff deflation pressure < cuff inflation pressure. SBP was measured in 226 male Wistar and SHR utilizing compression intervals of different durations, and also pharmacological interventions intended to modulate the cuff deflation-cuff inflation cycle. Direct, simultaneous intravascular measurements were also performed in some animals. With compression interval congruent with 15 s, cuff deflation-cuff inflation was--6 +/- 0.6 mmHg in 73 Wistar and--6 +/- 1.4 mmHg in 51 SHR. Lengthening compression interval up to 4 min increased cuff deflation-cuff inflation pressure significantly to--27 +/- 3 mmHg in Wistar and to - 31 +/- 5 mmHg in SHR, suggesting accumulation of a vasodilating mediator. This increase of cuff deflation-cuff inflation pressure was prevented by papaverine (totally in Wistar, partially in SHR), indicating its dependence on vasodilatory capacity. Adrenergic blockade decreased cuff deflation-cuff inflation pressure to--13 +/- 5 mmHg (P < 0.05) in SHR, but had no effect in Wistar rats. Injection of L-NAME decreased cuff deflation-cuff inflation pressure to--5 +/- 2 mmHg (P < 0.05) in Wistar rats but was ineffective in SHR. Simultaneous measurements by tail-cuff method and carotid cannulation revealed that the cuff inflation most accurately estimated the intravascular SBP. 1) Cuff inflation measurements should be considered representative of SBP, as cuff deflation can underestimate SBP depending on compression interval duration, 2) nitric oxide accumulation due to flow deprivation is the main cause of SBP underestimation by cuff deflation in Wistar, and 3) in SHR, nitric oxide effects were minimal
Stevens, Gregory J; Warfel, Joel W; Aden, James K; Blackwell, Scott D
2018-02-13
Endotracheal intubation is a medical procedure that is often indicated in both the perioperative and critical care environments. Cuffed endotracheal tubes (ETT) allow for safer and more efficient delivery of positive pressure ventilation, as well as create a barrier to reduce the risk of micro-aspiration and anesthetic pollution in the operating room environment. Over-inflation of the endotracheal cuff can lead to serious and harmful sequelae. This study aimed to assess if departmental education paired with ready access to a manometer to assess cuff pressure would result in an improvement in the proportion of ETT cuff pressures in the goal range. A quality improvement study was conducted at the San Antonio Military Medical Center (SAMMC; Department of Defense hospital in San Antonio, TX). The initiative was divided into three key periods: pre-implementation, implementation, and post-implementation. During the pre-implementation period, ETT cuff pressures were obtained to assess the baseline state of ETT cuff pressures for patients in the operating room; the proportion of in-range (20-30 cmH2O) pressures was calculated. During the implementation phase, operating rooms were equipped with manometers and anesthesia departmental education was performed regarding the use of the manometers. Three months later, post-implementation cuff pressures were measured in the OR, and the proportion of in-range pressures was again calculated. The pre-implementation data showed an average cuff pressure of 48.92 cmH2O and a median of 38.5 cmH2O. Of the 100 pre-implementation pressures, 20 were in the goal range. Post-implementation data had an average cuff pressure of 41.96 cmH2O and a median of 30 cmH2O. A chi-squared test of pressures in the safe range from the pre-implementation versus post-implementation values yielded a highly significant p-value of 0.0003. The data from this study clearly demonstrated a statistically significant improvement in the proportion of in-range cuff
Schumann, R; Alyamani, O; Viswanath, A; Bonney, I
2016-01-01
The purpose of this study was to determine the correlation between body mass index (BMI) and upper and lower arm as well as lower leg circumferences and the frequency of correct blood pressure (BP) cuff fit. We explored recommendations for the most likely BP cuff size and location for the three BMI categories. Following IRB approval we retrospectively analyzed a research database of bariatric surgical patients with a BMI of ≥40 kg/m(2). Data included patients' characteristics, upper and lower arm as well as lower leg circumferences. Patients were divided into three groups based on BMI (kg/m(2), Group I: <45, Group II: 45-55, and Group III: >55). Appropriate cuff fit using a standard or large adult BP cuff (CRITIKON(®), GE Healthcare, Waukesha, Wisconsin, USA) on the upper and lower arm, and lower leg was determined. We analyzed the percent proportion of proper cuff fit for cuff sizes and locations between groups using appropriate nonparametric testing. Limb circumference correlated significantly with BMI (P = 0.01), and the upper arm correlated most closely (r = 0.76). A standard adult BP cuff on the lower arm fit properly in >90% and >80% and in Groups I and II, respectively. A large cuff on the lower arm was appropriate in 87% of Group III. In two participants, a large cuff fit properly on the lower leg. Limb circumference significantly correlated with BMI. Recommendations for proper cuff fit in different BMI categories can be made.
Exploding a myth: the capsule dehiscence mechanism and the function of pseudostomata in Sphagnum.
Duckett, Jeffrey G; Pressel, Silvia; P'ng, Ken M Y; Renzaglia, Karen S
2009-01-01
The nineteenth century air-gun explanation for explosive spore discharge in Sphagnum has never been tested experimentally. Similarly, the function of the numerous stomata ubiquitous in the capsule walls has never been investigated. Both intact and pricked Sphagnum capsules, that were allowed to dry out, all dehisced over an 8-12 h period during which time the stomatal guard cells gradually collapsed and their potassium content, measured by X-ray microanalysis in a cryoscanning electron microscope, gradually increased. By contrast, guard cell potassium fell in water-stressed Arabidopsis. The pricking experiments demonstrate that the air-gun notion for explosive spore discharge in Sphagnum is inaccurate; differential shrinkage of the capsule walls causes popping off the rigid operculum. The absence of evidence for a potassium-regulating mechanism in the stomatal guard cells and their gradual collapse before spore discharge indicates that their sole role is facilitation of sporophyte desiccation that ultimately leads to capsule dehiscence. Our novel functional data on Sphagnum, when considered in relation to bryophyte phylogeny, suggest the possibility that stomata first appeared in land plants as structures that facilitated sporophyte drying out before spore discharge and only subsequently acquired their role in the regulation of gaseous exchange.
Arthroscopic rotator cuff debridement without decompression for the treatment of tendinosis.
Budoff, Jeffrey E; Rodin, Dennis; Ochiai, Derek; Nirschl, Robert P
2005-09-01
The treatment of rotator cuff injury in the absence of a full-thickness tear has traditionally consisted of acromioplasty. However, this disorder may also be treated by arthroscopic rotator cuff debridement without acromioplasty. Our previous study of 79 shoulders so treated reported 87% good or excellent results at an average 53-month follow-up. The purpose of this article is to report the long-term, average 9.5-year follow-up of this cohort. Long-term follow-up of case series. We retrospectively reviewed the records of 62 shoulders in 60 patients who had undergone arthroscopic rotator cuff debridement for partial-thickness rotator cuff tears. Demographic criteria, residual pain, and the ability to return to recreational athletics were noted. The UCLA Shoulder Score and the Simple Shoulder Test scores were determined and statistical analysis performed. Using the UCLA Shoulder Score, there were 79% excellent or good results at an average 114 months of follow-up. Patients with Workers' Compensation claims had significantly worse results, with only 40% rated good or excellent. Of the 60 patients, 77% had no or only minimal pain, 57% were still able to perform recreational athletics without difficulty, and 20% could participate at a lower level of intensity. Arthroscopic debridement of rotator cuff injury in the absence of a full-thickness tear has good long-term results and minimizes additional surgical trauma. Level IV, case series.
Infection Rates in Arthroscopic Versus Open Rotator Cuff Repair.
Hughes, Jonathan D; Hughes, Jessica L; Bartley, Justin H; Hamilton, William P; Brennan, Kindyle L
2017-07-01
The prevalence of rotator cuff repair continues to rise, with a noted transition from open to arthroscopic techniques in recent years. One reported advantage of arthroscopic repair is a lower infection rate. However, to date, the infection rates of these 2 techniques have not been directly compared with large samples at a single institution with fully integrated medical records. To retrospectively compare postoperative infection rates between arthroscopic and open rotator cuff repair. Cohort study; Level of evidence, 3. From January 2003 until May 2011, a total of 1556 patients underwent rotator cuff repair at a single institution. These patients were divided into an arthroscopic repair group and an open group. A Pearson chi-square test and Fisher exact test were used, with a subgroup analysis to segment the open repair group into mini-open and open procedures. The odds ratio and 95% CI of developing a postoperative infection was calculated for the 2 groups. A multiple-regressions model was then utilized to identify predictors of the presence of infection. Infection was defined as only those treated with surgical intervention, thus excluding superficial infections treated with antibiotics alone. A total of 903 patients had an arthroscopic repair, while 653 had open repairs (600 mini-open, 53 open). There were 4 confirmed infections in the arthroscopic group and 16 in the open group (15 mini-open, 1 open), resulting in postoperative infection rates of 0.44% and 2.45%, respectively. Subgroup analysis of the mini-open and open groups demonstrated a postoperative infection rate of 2.50% and 1.89%, respectively. The open group had an odds ratio of 5.645 (95% CI, 1.9-17.0) to develop a postoperative infection compared with the arthroscopic group. Patients undergoing open rotator cuff repair had a significantly higher rate of postoperative infection compared with those undergoing arthroscopic rotator cuff repair.
Muscle atrophy and fatty infiltration after an acute rotator cuff repair in a sheep model
Luan, Tammy; Liu, Xuhui; Easley, Jeremiah T.; Ravishankar, Bharat; Puttlitz, Christian; Feeley, Brian T.
2015-01-01
Summary Introduction rotator cuff tears (RCTs) are the most common tendon injury seen in orthopedic patients. Muscle atrophy and fatty infiltration of the muscle are crucial factors that dictate the outcome following rotator cuff surgery. Though less studied in humans, rotator cuff muscle fibrosis has been seen in animal models as well and may influence outcomes as well. The purpose of this study was to determine if the rotator cuff would develop muscle changes even in the setting of an acute repair in a sheep model. We hypothesized that fatty infiltration and fibrosis would be present even after an acute repair six months after initial surgery. Methods twelve female adult sheep underwent an acute rotator cuff tear and immediate repair on the right shoulder. The left shoulder served as a control and did not undergo a tear or a repair. Six months following acute rotator cuff repairs, sheep muscles were harvested to study atrophy, fatty infiltration, and fibrosis by histological analysis, western blotting, and reverse transcription polymerase chain reaction (RT-PCR). Results the repair group demonstrated an increase expression of muscle atrophy, fatty infiltration, and fibrosis related genes. Significantly increased adipocytes, muscle fatty infiltration, and collagen deposition was observed in rotator cuff muscles in the tendon repair group compared to the control group. Conclusions rotator cuff muscle undergoes degradation changes including fatty infiltration and fibrosis even after the tendons are repair immediately after rupture. Level of Evidence Basic Science Study. PMID:26261789
Advances in biologic augmentation for rotator cuff repair
Patel, Sahishnu; Gualtieri, Anthony P.; Lu, Helen H.; Levine, William N.
2016-01-01
Rotator cuff tear is a very common shoulder injury that often necessitates surgical intervention for repair. Despite advances in surgical techniques for rotator cuff repair, there is a high incidence of failure after surgery because of poor healing capacity attributed to many factors. The complexity of tendon-to-bone integration inherently presents a challenge for repair because of a large biomechanical mismatch between the tendon and bone and insufficient regeneration of native tissue, leading to the formation of fibrovascular scar tissue. Therefore, various biological augmentation approaches have been investigated to improve rotator cuff repair healing. This review highlights recent advances in three fundamental approaches for biological augmentation for functional and integrative tendon–bone repair. First, the exploration, application, and delivery of growth factors to improve regeneration of native tissue is discussed. Second, applications of stem cell and other cell-based therapies to replenish damaged tissue for better healing is covered. Finally, this review will highlight the development and applications of compatible biomaterials to both better recapitulate the tendon–bone interface and improve delivery of biological factors for enhanced integrative repair. PMID:27750374
Rotator Cuff Tear Arthropathy: Pathophysiology, Imaging Characteristics, and Treatment Options.
Eajazi, Alireza; Kussman, Steve; LeBedis, Christina; Guermazi, Ali; Kompel, Andrew; Jawa, Andrew; Murakami, Akira M
2015-11-01
The purpose of this article is to review the biomechanical properties of the rotator cuff and glenohumeral joint and the pathophysiology, imaging characteristics, and treatment options of rotator cuff tear arthropathy (RCTA). Although multiple pathways have been proposed as causes of RCTA, the exact cause remains unclear. Increasing knowledge about the clinical diagnosis, imaging features, and indicators of severity improves recognition and treatment of this pathologic condition.
... prep - vaginitis; Vaginosis - wet mount; Trichomoniasis - wet mount; Vaginal candida - wet mount ... provider gently inserts an instrument (speculum) into the vagina to hold it open and view inside. A ...
Friedrich, E G
1985-06-01
Vaginitis is one of the most common complaints of women in the United States today. About 90% of patients with this problem suffer from infection of the vagina caused by Candida, Gardnerella, or Trichomonas. The diagnosis and effective treatment of these common infections depend on accurate identification of the entity, effective specific therapy, and restoration of the normal ecosystem of the vagina. At the same time women should be made aware that not all discharge means infection and that any attempts at self-treatment may only worsen their condition. Proper hygiene habits, dietary control, and management of stress are all helpful factors in the control of recurrent vaginal infections.
Maruyama, Naho; Takizawa, Toshio; Ishibashi, Hiroko; Hisajima, Tatsuya; Inouye, Shigeharu; Yamaguchi, Hideyo; Abe, Shigeru
2008-08-01
In order to evaluate an effective administration method of essential oils for vaginal candidiasis, efficacy of vaginal application of essential oils against murine experimental candidiasis was investigated. The effect on vaginal inflammation and Candida growth form was also studied. Vaginal candidiasis was established by intravaginal infection of C. albicans to estradiol-treated mice. These mice intravaginally received essential oils such as geranium and tea tree singly or in combination with vaginal washing. Vaginal administration of clotrimazole significantly decreased the number of viable C. albicans cells in the vaginal cavity by itself. In contrast, these essential oils did not lower the cell number. When application of geranium oil or geraniol was combined with vaginal washing, the cell number was decreased significantly. The myeloperoxidase activity assay exhibited the possibility that essential oils worked not only to reduce the viable cell number of C. albicans, but also to improve vaginal inflammation. The smear of vaginal washing suspension suggested that more yeast-form cells appeared in vaginal smears of these oil-treated mice than in control mice. In vitro study showed that a very low concentration (25 microg/ml) of geranium oil and geraniol inhibited mycelial growth, but not yeast growth. Based on these findings, it is estimated that vaginal application of geranium oil or its main component, geraniol, suppressed Candida cell growth in the vagina and its local inflammation when combined with vaginal washing.
Risk Factors, Pathobiomechanics and Physical Examination of Rotator Cuff Tears
Moulton, Samuel G.; Greenspoon, Joshua A.; Millett, Peter J.; Petri, Maximilian
2016-01-01
Background: It is important to appreciate the risk factors for the development of rotator cuff tears and specific physical examination maneuvers. Methods: A selective literature search was performed. Results: Numerous well-designed studies have demonstrated that common risk factors include age, occupation, and anatomic considerations such as the critical shoulder angle. Recently, research has also reported a genetic component as well. The rotator cuff axially compresses the humeral head in the glenohumeral joint and provides rotational motion and abduction. Forces are grouped into coronal and axial force couples. Rotator cuff tears are thought to occur when the force couples become imbalanced. Conclusion: Physical examination is essential to determining whether a patient has an anterosuperior or posterosuperior tear. Diagnostic accuracy increases when combining a series of examination maneuvers. PMID:27708731
Genetic and familial predisposition to rotator cuff disease: a systematic review.
Dabija, Dominique I; Gao, Chan; Edwards, Todd L; Kuhn, John E; Jain, Nitin B
2017-06-01
Rotator cuff disease is a common disorder leading to shoulder pain and loss of function. Its etiology in atraumatic cases is uncertain and is likely to extend beyond repetitive microtrauma or overuse. Our objective was to determine whether there is a genetic or familial predisposition to rotator cuff disease. A literature search of PubMed and Embase databases identified 251 citations. After review of the titles, abstracts, and full articles, 7 met our inclusion and exclusion criteria. Four studies assessed familial predisposition to rotator cuff disease. One of these demonstrated that siblings of an individual with a rotator cuff tear were more likely to develop a full-thickness tear and more likely to be symptomatic. A 5-year follow-up showed that the relative risks were increased for the siblings to have a full-thickness tear, for a tear to progress in size, and for being symptomatic. Another study demonstrated that a significantly higher number of individuals with tears had family members with a history of tears or surgery than those without tears did. The other 3 studies investigated whether a genetic predisposition to rotator cuff disease exists and found significant association of haplotypes in DEFB1, FGFR1, FGF3, ESRRB, and FGF10 and 2 single-nucleotide polymorphisms within SAP30BP and SASH1. Prior studies provide preliminary evidence for genetic and familial predisposition to rotator cuff disease. However, there is a lack of large genome-wide studies that can provide more definitive information and guide early detection of individuals at risk, prophylactic rehabilitation, and potential gene therapies and regenerative medicine interventions. Copyright © 2016 Journal of Shoulder and Elbow Surgery Board of Trustees. Published by Elsevier Inc. All rights reserved.
Palacios, Santiago; Losa, Fernando; Dexeus, Damián; Cortés, Javier
2017-03-16
To assess the effect of a 12-day treatment using a vaginal gel based on niosomes containing hyaluronic acid, ß-glucan, alpha-glucan oligosaccharide, Coriolus versicolor, Asian centella, Azadirachta indica and Aloe vera on vaginal microbiota, cervical epithelization and vaginal health. Open-label, prospective pilot study conducted in asymptomatic women in daily practice. Cervical epithelization was evaluated by colposcopy using an ectopy epithelization score (from 5: no ectopy to 1: severe ectopy and bleeding), vaginal microbiota using the VaginaStatus-Diagnostic test (Instiüt für Mikroökologie, Herborn, Germany) and further rated by the investigator using a 5-point Liker scale (from 5: normal to 1: very severe deterioration in which all evaluated species were altered), and vaginal health using the Vaginal Health Index. In 21 women, a positive effect to improve epithelization of the cervical mucosa, with a mean score of 4.42 at the final visit as compared to 3.09 at baseline (P < 0.0001) (43% improvement). In 10 women, there was a trend of improving of vaginal microbiota status, with a mean score of 4.0 at the final visit vs. 3.3 at baseline (P = NS) (21.2% improvement). In 11 women, the Vaginal Health Index increased from 19.0 at baseline to 22.3 at the final visit (P = 0.007). The concentration of Lactobacillus spp. increased 54.5% of women and pH decreased from 4.32 to 4.09. These encouraging preliminary results provide the basis for designing a randomized controlled study, and for potential use in human papilloma virus infection. ISRCTN77955077 . Registration date: February 15, 2017. Retrospectively registered.
Tashjian, Robert Z; Granger, Erin K; Farnham, James M; Cannon-Albright, Lisa A; Teerlink, Craig C
2016-02-01
The precise etiology of rotator cuff disease is unknown, but prior evidence suggests a role for genetic factors. Limited data exist identifying specific genes associated with rotator cuff tearing. The purpose of this study was to identify specific genes or genetic variants associated with rotator cuff tearing by a genome-wide association study with an independent set of rotator cuff tear cases. A set of 311 full-thickness rotator cuff tear cases genotyped on the Illumina 5M single-nucleotide polymorphism (SNP) platform were used in a genome-wide association study with 2641 genetically matched white population controls available from the Illumina iControls database. Tests of association were performed with GEMMA software at 257,558 SNPs that compose the intersection of Illumina SNP platforms and that passed general quality control metrics. SNPs were considered significant if P < 1.94 × 10(-7) (Bonferroni correction: 0.05/257,558). Tests of association revealed 2 significantly associated SNPs, one occurring in SAP30BP (rs820218; P = 3.8E-9) on chromosome 17q25 and another occurring in SASH1 (rs12527089; P = 1.9E-7) on chromosome 6q24. This study represents the first attempt to identify genetic factors influencing rotator cuff tearing by a genome-wide association study using a dense/complete set of SNPs. Two SNPs were significantly associated with rotator cuff tearing, residing in SAP30BP on chromosome 17 and SASH1 on chromosome 6. Both genes are associated with the cellular process of apoptosis. Identification of potential genes or genetic variants associated with rotator cuff tearing may help in identifying individuals at risk for the development of rotator cuff tearing. Copyright © 2016 Journal of Shoulder and Elbow Surgery Board of Trustees. Published by Elsevier Inc. All rights reserved.
Single-Versus Double-Row Arthroscopic Rotator Cuff Repair in Massive Tears
Wang, EnZhi; Wang, Liang; Gao, Peng; Li, ZhongJi; Zhou, Xiao; Wang, SongGang
2015-01-01
Background It is a challenge for orthopaedic surgeons to treat massive rotator cuff tears. The optimal management of massive rotator cuff tears remains controversial. Therefore, the goal of this study was to compare arthroscopic single- versus double-row rotator cuff repair with a larger sample size. Material/Methods Of the subjects with massive rotator cuff tears, 146 were treated using single-row repair, and 102 were treated using double-row repair. Pre- and postoperative functional outcomes and radiographic images were collected. The clinical outcomes were evaluated for a minimum of 2 years. Results No significant differences were shown between the groups in terms of functional outcomes. Regarding the integrity of the tendon, a lower rate of post-treatment retear was observed in patients who underwent double-row repair compared with single-row repair. Conclusions The results suggest that double-row repair is relatively superior in shoulder ROM and the strength of tendon compared with single-row repair. Future studies involving more patients in better-designed randomized controlled trials will be required. PMID:26017641
"Long-term stability of stimulating spiral nerve cuff electrodes on human peripheral nerves".
Christie, Breanne P; Freeberg, Max; Memberg, William D; Pinault, Gilles J C; Hoyen, Harry A; Tyler, Dustin J; Triolo, Ronald J
2017-07-11
Electrical stimulation of the peripheral nerves has been shown to be effective in restoring sensory and motor functions in the lower and upper extremities. This neural stimulation can be applied via non-penetrating spiral nerve cuff electrodes, though minimal information has been published regarding their long-term performance for multiple years after implantation. Since 2005, 14 human volunteers with cervical or thoracic spinal cord injuries, or upper limb amputation, were chronically implanted with a total of 50 spiral nerve cuff electrodes on 10 different nerves (mean time post-implant 6.7 ± 3.1 years). The primary outcome measures utilized in this study were muscle recruitment curves, charge thresholds, and percent overlap of recruited motor unit populations. In the eight recipients still actively involved in research studies, 44/45 of the spiral contacts were still functional. In four participants regularly studied over the course of 1 month to 10.4 years, the charge thresholds of the majority of individual contacts remained stable over time. The four participants with spiral cuffs on their femoral nerves were all able to generate sufficient moment to keep the knees locked during standing after 2-4.5 years. The dorsiflexion moment produced by all four fibular nerve cuffs in the active participants exceeded the value required to prevent foot drop, but no tibial nerve cuffs were able to meet the plantarflexion moment that occurs during push-off at a normal walking speed. The selectivity of two multi-contact spiral cuffs was examined and both were still highly selective for different motor unit populations for up to 6.3 years after implantation. The spiral nerve cuffs examined remain functional in motor and sensory neuroprostheses for 2-11 years after implantation. They exhibit stable charge thresholds, clinically relevant recruitment properties, and functional muscle selectivity. Non-penetrating spiral nerve cuff electrodes appear to be a suitable option
Vaginal metastasis presenting as postmenopausal bleeding.
Ng, Qiu Ju; Namuduri, Rama Padma; Yam, Kwai Lam; Lim-Tan, Soo Kim
2015-08-01
Vaginal cancer is rare worldwide and represents 2% of all gynaecological cancers in Singapore. Primary vaginal malignancies are rare and vaginal metastases constitute the majority of vaginal malignancies. Most of these metastases arise from the cervix, endometrium or ovary, although they can also metastasise from distant sites such as the colon, breast and pancreas. We report a rare case of vaginal metastasis in a patient with previous gastric and rectal adenocarcinomas. An 89-year-old woman with a history of gastric and rectal malignancy presented with postmenopausal bleeding. A 2-cm vaginal tumour at the introitus was discovered upon examination. This case demonstrates the importance of performing a gynaecological examination during follow-up for patients with a history of malignancy. The prognosis for vaginal metastasis is poor, as it is often associated with disseminated disease. Depending on the extent of the lesions, radiotherapy or surgery can be considered.
Otsuki, Katsufumi; Tokunaka, Mayumi; Oba, Tomohiro; Nakamura, Masamitsu; Shirato, Nahoko; Okai, Takashi
2014-02-01
Lactoferrin (LF) is one of the prebiotics present in the human body. A 38-year-old multiparous woman with poor obstetrical histories, three consecutive preterm premature rupture of membrane at the 19th, 23rd and 25th week of pregnancy, was referred to our hospital. She was diagnosed as having refractory vaginitis. Although estriol vaginal tablets were used for 4 months, the vaginitis was not cured. We administrated vaginal tablets and oral agents of prebiotic LF, resulting in a Lactobacillus predominant vaginal flora. When she was pregnant, she continued to use the LF, and the Lactobacillus in the vaginal flora was continuously observed during pregnancy. An elective cesarean section was performed at the 38th week of pregnancy. When the administration of LF was discontinued after the delivery, Lactobacillus in the vaginal flora was disappeared. © 2013 The Authors. Journal of Obstetrics and Gynaecology Research © 2013 Japan Society of Obstetrics and Gynecology.
Paré, Jessica; Froehlich, John E
2017-01-01
Context Recent advances within the field of genetics are currently changing many of the methodologies in which medicine is practiced. These advances are also beginning to influence the manner in which physical therapy services are rendered. Rotator cuff pathology is one of the most common diagnoses treated by the sports physical therapist. The purpose of this commentary is to educate sports physical therapists on the recent advances regarding how genetics influences rotator cuff pathology, including rotator cuff tears, and provide a perspective on how this information will likely influence post-operative shoulder rehabilitation in the near future. Evidence Acquisition A comprehensive review of the literature was completed using the Medline database along with individual searches of relevant physical therapy, surgical, cell biology, and sports medicine journals. Search terms included: shoulder, rotator cuff pathology, genetics, apoptosis, and physical therapy. Search results were compiled and evaluated; relevant primary studies and review articles were gathered; the results from this comprehensive review are summarized here. Study Design Clinical Commentary, Review of the Literature Results Recent advances within the understanding of rotator cuff pathology have further elucidated the cellular and molecular mechanisms associated with rotator cuff tears. There appears to be a hypoxic-induced apoptotic cellular pathway that contributes to rotator cuff tears. Activation of specific proteins termed matrix metalloproteinases appear to be involved in not only primary rotator cuff tears, but also may influence the re-tear rate after surgical intervention. Further advancements in the understanding of the cellular mechanisms contributing to rotator cuff tears and postoperative techniques to help prevent re-tears, may soon influence the methodology in which physical therapy services are provided to patients sustaining a rotator cuff injury. Conclusions At this time continued
Huang, Ling; Xie, Chen; Zhang, Lifeng; Meng, Liying; Li, Guizheng; Li, Yang; Huang, Bing; Pan, Linghui; Tang, Zhanhong
2017-01-01
To discuss the influence of intermittently monitoring on endotracheal tube cuff pressure using handheld pressure gauge, and to provide some reference for the clinical work. The experiment was carried out on the model of the glass tube, which was divided into three parts. Each part of the experiment was divided into normal pressure group and high pressure group according to the different inflation pressure target value. The endotracheal tube cuff pressure was determined intermittently by using the transparent tracheal models which had a static diameter of 2 cm. The target press value of normal pressure group was 32 cmH 2 O (1 cmH 2 O = 0.098 kPa) while that of high pressure group was 40 cmH 2 O. The handheld pressure gauge was connected with the indicated cuff through a tee joint, and the pressure in the cuff in both groups was determined. The pressure loss caused by intermittent measurement of the two groups was compared. By switching the tee joint, the pressure loss through the gauge self-structure and the pressure loss when connecting and disconnecting the indicated cuff were determined to analyze the causes of pressure loss caused by intermittent measurement of pressure gauge. The pressure loss caused by intermittent measurement of high pressure group was significantly higher than that of normal pressure group (cmH 2 O: 15.10±0.43 vs. 10.19±0.45) with statistical significance (t = -24.875, P = 0.000). The pressure loss through the gauge self-structure of high pressure group was also significantly higher than that of normal pressure group (cmH 2 O: 13.91±0.48 vs. 8.77±0.53), which showed a statistics significance (t = -22.854, P = 0.000). The pressure loss when connecting and disconnecting the indicated cuff of the normal pressure and high pressure groups were (1.33±0.49) cmH 2 O and (1.23±0.55) cmH 2 O, respectively, without statistics significance (t = 0.445, P = 0.662). It was figured that the total pressure loss caused by intermittent measurement of the
Reyes, Bryan A; Hull, Brandon R; Kurth, Alexander B; Kukowski, Nathan R; Mulligan, Edward P; Khazzam, Michael S
2017-11-01
Many patients with rotator cuff tears suffer from nocturnal shoulder pain, resulting in sleep disturbance. To determine whether rotator cuff tear size correlated with sleep disturbance in patients with full-thickness rotator cuff tears. Cross-sectional study; Level of evidence, 3. Patients with a diagnosis of unilateral full-thickness rotator cuff tears (diagnosed via magnetic resonance imaging [MRI]) completed the Pittsburgh Sleep Quality Index (PSQI), a visual analog scale (VAS) quantifying their shoulder pain, and the American Shoulder and Elbow Surgeons (ASES) questionnaire. Shoulder MRI scans were analyzed for anterior-posterior tear size (mm), tendon retraction (mm), Goutallier grade (0-4), number of tendons involved (1-4), muscle atrophy (none, mild, moderate, or severe), and humeral head rise (present or absent). Bivariate correlations were calculated between the MRI characteristics and baseline survey results. A total of 209 patients with unilateral full-thickness rotator cuff tears were included in this study: 112 (54%) female and 97 (46%) male (mean age, 64.1 years). On average, shoulder pain had been present for 24 months. The mean PSQI score was 9.8, and the mean VAS score was 5.0. No significant correlations were found between any of the rotator cuff tear characteristics and sleep quality. Only tendon retraction had a significant correlation with pain. Although rotator cuff tears are frequently associated with nocturnal pain and sleep disruption, this study demonstrated that morphological characteristics of full-thickness rotator cuff tears, such as size and tendon retraction, do not correlate with sleep disturbance and have little to no correlation with pain levels.
Bayle, Xavier; Pham, Thuy-Trang; Faruch, Marie; Gobet, Aurelie; Mansat, Pierre; Bonnevialle, Nicolas
2017-12-01
Arthroscopic techniques tend to become the gold standard in rotator cuff repair. However, little data are reported in the literature regarding the improvement of postoperative outcomes and re-tear rate relative to conventional open surgery. The aim of this study was to compare clinical outcomes and cuff integrity after arthroscopic versus open cuff repair. We prospectively assessed clinical outcomes and cuff integrity after an arthroscopic or open rotator cuff repair with a minimum follow-up of 12 months. Clinical evaluation was based on Constant score, Simple Shoulder Value (SSV) and American Shoulder and Elbow Score (ASES). Rotator cuff healing was explored with ultrasound. 44 patients in arthroscopic group A (mean age 56-year-old) and 43 in open group O (mean age 61-year-old) fulfilled the inclusion criteria. Tendons were repaired with a single row technique associated with biceps tenodesis and subacromial decompression. All objective clinical scores significantly improved postoperatively in both groups. No statistical difference was identified between group A and O regarding, respectively, Constant score (72 vs 75 points; p = 0.3), ASES score (88 vs 91 points; p = 0.3), and SSV (81 vs 85%). The overall rate of re-tear (Sugaya type IV or V) reached 7 and 9%, respectively, in group A and O (p = 0.8). This study did not prove any difference of arthroscopic over open surgery in case of rotator cuff repair regarding clinical outcome and cuff integrity at 1-year follow-up. Prospective comparative study.
Automated Control of Endotracheal Tube Cuff Pressure during Simulated Flight
2016-06-21
accomplished in the intensive care unit (ICU) with stand-alone devices as well as those integral to a ventilator [13,14]. We hypothesized that closed loop ... Administration approved automatic cuff pressure adjustment devices (Intellicuff, Hamilton Medical , Reno, NV; Pyton, ARM Medical , Bristol, CT; Cuff Sentry, Outcome...711th Human Performance Wing U.S. Air Force School of Aerospace Medicine Int’l Expeditionary Educ & Training Dept Air Force Expeditionary Medical
Automated Control of Endotracheal Tube Cuff Pressure During Simulated Flight
2016-06-01
ventilator, while the other two devices are stand-alone products. The fourth group of ETTs had the cuff pressure measured by the respiratory ...Maquet, Rastatt, Germany). To simulate a clinical environment, each model was ventilated using ventilator settings of respiratory rate of 12...rapidly changes with descent to below 10 cmH2O, allowing fluid above the cuff to readily move into the lower respiratory tract. As with ascent
Vaginal sponge and spermicides
Birth control - over the counter; Contraceptives - over the counter; Family planning - vaginal sponge; Contraception - vaginal sponge ... preventing pregnancy as some other forms of birth control. However, using a spermicide or sponge is much ...
Rotator cuff repair healing influenced by platelet-rich plasma construct augmentation.
Barber, F Alan; Hrnack, Scott A; Snyder, Stephen J; Hapa, Onur
2011-08-01
To assess the effect of platelet-rich plasma fibrin matrix (PRPFM) construct augmentation on postoperative tendon healing as determined by magnetic resonance imaging (MRI) and clinical outcome of arthroscopic rotator cuff repair. A comparative series of patients undergoing arthroscopic rotator cuff repair was studied. Two matched groups of patients (20 each) were included: rotator cuff repairs without PRPFM augmentation (group 1) and rotator cuff repairs augmented with 2 sutured platelet-rich plasma (PRP) constructs (group 2). A single-row cuff repair to the normal footprint without tension or marrow vents was performed by a single surgeon. Postoperative rehabilitation was held constant. Postoperative MRI scans were used to evaluate rotator cuff healing. Outcome measures included American Shoulder and Elbow Surgeons, Rowe, Single Assessment Numeric Evaluation, Simple Shoulder Test, and Constant scores. We followed up 40 patients (2 matched groups with 20 patients each) with a mean age of 57 years (range, 44 to 69 years) for a mean of 31 months (range, 24 to 44 months). Postoperative MRI studies showed persistent full-thickness tendon defects in 60% of controls (12 of 20) and 30% of PRPFM-augmented repairs (6 of 20) (P = .03). Of the control group tears measuring less than 3 cm in anteroposterior length, 50% (7 of 14) healed fully, whereas 86% of the PRPFM group tears measuring less than 3 cm in anteroposterior length (12 of 14) healed fully (P < .05). There was no significant difference between groups 1 and 2 in terms of American Shoulder and Elbow Surgeons (94.7 and 95.7, respectively; P = .35), Single Assessment Numeric Evaluation (93.7 and 94.5, respectively; P = .37), Simple Shoulder Test (11.4 and 11.3, respectively; P = .41), and Constant (84.7 and 88.1, respectively; P = .19) scores. The Rowe scores (84.8 and 94.9, respectively; P = .03) were statistically different. The addition of 2 PRPFM constructs sutured into a primary rotator cuff tendon repair
Osteoarthritis after rotator cuff repair: A 10-year follow-up study.
Flurin, P-H; Hardy, P; Valenti, P; Meyer, N; Collin, P; Kempf, J-F
2017-06-01
Joint surgery is often complicated by gradual bone and cartilage deterioration that eventually leads to secondary osteoarthritis. The primary objective of this study was to identify preoperative risk factors for gleno-humeral osteoarthritis after rotator cuff repair. The secondary objectives were to assess whether the risk of gleno-humeral osteoarthritis was influenced by the operative technique, occurrence of postoperative complications, cuff healing, and muscle degeneration and to determine whether gleno-humeral osteoarthritis affected the clinical outcome. The development of gleno-humeral osteoarthritis affects the postoperative clinical outcome. A retrospective multicentre study of patients who underwent rotator cuff repair in 2003 and were re-evaluated at least 10 years later was conducted under the aegis of the Société française de chirurgie orthopédique et traumatique (SOFCOT). Osteoarthritis severity was graded according to the Samilson-Prieto classification. Four hundred and one patients were included. At last follow-up, at least 10 years after surgery, the radiological Samilson-Prieto grades were distributed as follows: 0, n=181 (45%); 1, n=142 (n=35%); 2, n=57 (14%); 3, n=14 (4%); and 4, n=7 (2%). The mean Constant score was significantly higher in the patients without than with osteoarthritis at last follow-up (79/100 vs. 73/100, P<0.001). MRI assessment of cuff healing showed that the proportion of patients with osteoarthritis was significantly higher in the group with unhealed or re-torn cuffs (Sugaya type 4 or 5) than in the group with healed cuffs (Sugaya type 1, 2, or 3) (46% vs. 25%, P=0.012). Our study showed no associations linking the risk of gleno-humeral osteoarthritis to the patient activity profile, history of shoulder injury, or preoperative symptom duration. In contrast, statistically significant associations were identified between gleno-humeral osteoarthritis and age, male gender, initial tear severity, and the pain and mobility
Symptoms of Pain Do Not Correlate with Rotator Cuff Tear Severity
Dunn, Warren R.; Kuhn, John E.; Sanders, Rosemary; An, Qi; Baumgarten, Keith M.; Bishop, Julie Y.; Brophy, Robert H.; Carey, James L.; Holloway, G. Brian; Jones, Grant L.; Ma, C. Benjamin; Marx, Robert G.; McCarty, Eric C.; Poddar, Sourav K.; Smith, Matthew V.; Spencer, Edwin E.; Vidal, Armando F.; Wolf, Brian R.; Wright, Rick W.
2014-01-01
Background: For many orthopaedic disorders, symptoms correlate with disease severity. The objective of this study was to determine if pain level is related to the severity of rotator cuff disorders. Methods: A cohort of 393 subjects with an atraumatic symptomatic full-thickness rotator-cuff tear treated with physical therapy was studied. Baseline pretreatment data were used to examine the relationship between the severity of rotator cuff disease and pain. Disease severity was determined by evaluating tear size, retraction, superior humeral head migration, and rotator cuff muscle atrophy. Pain was measured on the 10-point visual analog scale (VAS) in the patient-reported American Shoulder and Elbow Surgeons (ASES) score. A linear multiple regression model was constructed with use of the continuous VAS score as the dependent variable and measures of rotator cuff tear severity and other nonanatomic patient factors as the independent variables. Forty-eight percent of the patients were female, and the median age was sixty-one years. The dominant shoulder was involved in 69% of the patients. The duration of symptoms was less than one month for 8% of the patients, one to three months for 22%, four to six months for 20%, seven to twelve months for 15%, and more than a year for 36%. The tear involved only the supraspinatus in 72% of the patients; the supraspinatus and infraspinatus, with or without the teres minor, in 21%; and only the subscapularis in 7%. Humeral head migration was noted in 16%. Tendon retraction was minimal in 48%, midhumeral in 34%, glenohumeral in 13%, and to the glenoid in 5%. The median baseline VAS pain score was 4.4. Results: Multivariable modeling, controlling for other baseline factors, identified increased comorbidities (p = 0.002), lower education level (p = 0.004), and race (p = 0.041) as the only significant factors associated with pain on presentation. No measure of rotator cuff tear severity correlated with pain (p > 0.25). Conclusions
Hassan, Sarmina; Chatwani, Ashwin; Brovender, Herman; Zane, Richard; Valaoras, Thomas; Sobel, Jack D
2011-04-01
To demonstrate the effectiveness of medical-grade stainless steel Water Works Douching Device for treating abnormal vaginal odor in comparison with a commercially available over-the-counter plastic douching device. In a multicenter study, 140 women with perceived vaginal odor with no vaginal infection were randomized to either Water Works or control group in a 1:1 ratio and were douched daily for 4 weeks. A visual analog scale (VAS) was used to assess the intensity of vaginal odor. Primary outcome included subject assessment of odor improvement and Nugent Gram stain score of vaginal secretions. Secondary outcome compared the efficacy and safety of Water Works with control douching device. Each patient underwent baseline, week 2, and week 4 visits. The final analytic sample consisted of 96 women. Success score at 4 weeks was 78% for the Water Works group and 38.5% for the control group. Mean VAS was significantly reduced, and Nugent and Lactobacillus scores were maintained in both groups. In the Water Works group, VAS was reduced from 7.3 ± 0.3 to 1.8 ± 0.6 (p < .001) after 4 weeks. In the control group, baseline versus 4 weeks VAS was 7.2 ± 0.3 and 3.4 ± 0.8 (p < .003). Women reported significant reduction of vaginal odor after douching with water for 4 weeks without any alteration of vaginal flora. The Water Works Douching Device was superior to over- the-counter device in reducing vaginal odor.
Singh, Nisha; Negi, Neha; Kumar, Namrata
2016-08-29
Surgical site infections remain a common cause of morbidity following gynaecological surgery. The widespread implementation of antibiotic prophylaxis prior to surgery, as well as cognizance of modifiable risk factors for postoperative infection, has led to a significant reduction in postoperative infection rates. However, in low resource settings where sepsis and infections are common, surgical site infections following vaginal hysterectomy are sometimes encountered. It is a challenge to treat these infections with minimal intervention avoiding repeat surgery. We report here a unique situation following vaginal hysterectomy and then laparotomy; where a pelvic abscess communicated with the vesicovaginal space and drained through an opening into the anterior vaginal wall. An innovative technique was used to drain this anterior vaginal wall abscess connecting to pelvic cavity using a 40 cm long disposable urinary catheter (made of polyvinyl chloride), which was inserted into the vaginal opening under ultrasound guidance. 2016 BMJ Publishing Group Ltd.
Melis, Gian Benedetto; Piras, Bruno; Marotto, Maria Francesca; Neri, Manuela; Corda, Valentina; Vallerino, Valerio; Saba, Alessandra; Lello, Stefano; Pilloni, Monica; Zedda, Pierina; Paoletti, Anna Maria; Mais, Valerio
2018-04-12
The vaginal immune system (VIS) is the first defense against antigens recognized as foreign. Substances capable of locally activating the VIS could be a valid strategy to treat vulvo-vaginal infections (VVI), caused by changes in the vaginal ecosystem, such as bacterial vaginosis (BV), vulvo-vaginal candidiasis (CA), and mixed vaginitis (MV). Bacterial lysates, obtained by crushing bacterial cultures, exert immuno-modulatory activities. The parietal fraction from Propionibacterium acnes is a patent of Depofarma (MoglianoVeneto, Italy). The preparation that associates such fraction to hyaluronic acid and polycarbophil is a registered trademark, commercially available in Italy as vaginal gel, Immunovag ® . The study aimed to evaluate whether a 5-day-treatment with Immunovag ® improves the symptoms and signs of VVI, in 60 women with Gardnerella vaginalis (GV), 154 with CA, 95 with MV, diagnosed with vulvar vaginal swab (VVS), and in 283 with BV, diagnosed with the Amsel criteria. At the end of the treatment (visit 2), the symptoms and signs of VVI disappeared in a significant number of subjects (χ 2 p < .02 vs pre-treatment) in all VVI groups, and their intensity was significantly (p < .0002) reduced in the subjects in which they were still present. Immunovag ® represents a valid treatment of VVI induced by changes in the vaginal ecosystem.
Clinical Assessment of Physical Examination Maneuvers for Rotator Cuff Lesions.
Somerville, Lyndsay E; Willits, Kevin; Johnson, Andrew M; Litchfield, Robert; LeBel, Marie-Eve; Moro, Jaydeep; Bryant, Dianne
2014-08-01
Shoulder pain and disability pose a diagnostic challenge for clinicians owing to the numerous causes that exist. Unfortunately, the evidence in support of most clinical tests is weak or absent. To determine the diagnostic validity of physical examination maneuvers for rotator cuff lesions. Cohort study (diagnosis); Level of evidence, 1. Consecutive shoulder patients recruited for this study were referred to 2 tertiary orthopaedic clinics. A surgeon took a thorough history and indicated his or her certainty about each possible diagnosis. A clinician performed the physical examination for diagnoses where uncertainty remained. Arthroscopy was considered the reference standard for patients who underwent surgery, and MRI with arthrogram was considered the reference for patients who did not. The sensitivity, specificity, and likelihood ratios were calculated to investigate whether combinations of the top tests provided stronger predictions of the presence or absence of disease. There were 139 participants. None of the tests were highly sensitive for diagnosing rotator cuff tears or tendinosis. Tests for subscapularis tears were all highly specific. No optimal combination of tests improved the ability to correctly diagnose rotator cuff tears. Closer analysis revealed the internal rotation and lateral rotation lag sign did not improve the ability to diagnose subscapularis or supraspinatus tears, respectively, although the lateral rotation lag sign demonstrated a discriminatory ability for tear size. No test in isolation is sufficient to diagnose a patient with rotator cuff damage. A combination of tests improves the ability to diagnose damage to the rotator cuff. It is recommended that the internal rotation and lateral rotation lag signs be removed from the gamut of physical examination tests for supraspinatus and subscapularis tears. © 2014 The Author(s).
Mannava, Sandeep; Plate, Johannes F; Tuohy, Christopher J; Seyler, Thorsten M; Whitlock, Patrick W; Curl, Walton W; Smith, Thomas L; Saul, Katherine R
2013-07-01
The purpose of this article is to review basic science studies using various animal models for rotator cuff research and to describe structural, biomechanical, and functional changes to muscle following rotator cuff tears. The use of computational simulations to translate the findings from animal models to human scale is further detailed. A comprehensive review was performed of the basic science literature describing the use of animal models and simulation analysis to examine muscle function following rotator cuff injury and repair in the ageing population. The findings from various studies of rotator cuff pathology emphasize the importance of preventing permanent muscular changes with detrimental results. In vivo muscle function, electromyography, and passive muscle-tendon unit properties were studied before and after supraspinatus tenotomy in a rodent rotator cuff injury model (acute vs chronic). Then, a series of simulation experiments were conducted using a validated computational human musculoskeletal shoulder model to assess both passive and active tension of rotator cuff repairs based on surgical positioning. Outcomes of rotator cuff repair may be improved by earlier surgical intervention, with lower surgical repair tensions and fewer electromyographic neuromuscular changes. An integrated approach of animal experiments, computer simulation analyses, and clinical studies may allow us to gain a fundamental understanding of the underlying pathology and interpret the results for clinical translation.
Talekar, C R; Udy, A A; Boots, R J; Lipman, J; Cook, D
2014-11-01
The application of tracheal cuff pressure monitoring is likely to vary between institutions. The aim of this study was therefore to review current evidence concerning this intervention in the intensive care unit (ICU) and to appraise regional practice by performing a state-wide survey. Publications for review were identified through searches of PubMed, EMBASE and Cochrane (1977 to 2014). All studies in English relevant to critical care and with complete data were included. Survey questions were developed by small-group consensus. Public and private ICUs across Queensland were contacted, with responses obtained from a representative member of the medical or nursing staff. Existing literature suggests significant variability in tracheal cuff pressure monitoring in the ICU, particularly in the applied technique, frequency of assessment and optimal intra-cuff pressures. Twenty-nine respondents completed the survey, representing 80.5% (29/36) of ICUs in Queensland. Twenty-eight out of twenty-nine respondents reported routinely monitoring tracheal cuff function, primarily employing cuff pressure measurement (26/28). Target cuff pressures varied, with 3/26 respondents aiming for 10 to 20 cmH2O, 10/26 for 21 to 25 cmH2O, and 13/26 for 26 to 30 cmH2O. Fifteen out of twenty-nine reported they had no current guideline or protocol for tracheal cuff management and only 16/29 indicated there was a dedicated area in the clinical record for reporting cuff intervention. Our results indicate that many ICUs across Queensland routinely measure tracheal cuff function, with most utilising pressure monitoring devices. Consistent with existing literature, the optimum cuff pressure remains uncertain. Most, however, considered that this should be a routine part of ICU care.
Cuff deflation: rehabilitation in critical care.
Bach, John R; Gonçalves, Miguel R; Rodriguez, Pedro Landete; Saporito, Louis; Soares, Luisa
2014-08-01
This is a case series of rehabilitation failures that resulted in severe reactive depression from patients unnecessarily bereft of verbal communication by being left to breathe or be ventilated via tracheostomy tubes, with or without inflated cuffs, for months to years.
Endotracheal tubes and fluid aspiration: an in vitro evaluation of new cuff technologies.
Mariyaselvam, Maryanne Z; Marsh, Lucy L; Bamford, Sarah; Smith, Ann; Wise, Matt P; Williams, David W
2017-03-04
Aspiration of subglottic secretions past the endotracheal tube (ETT) cuff is a prerequisite for developing ventilator-associated pneumonia (VAP). Subglottic secretion drainage (SSD) ETTs reduce aspiration of subglottic secretions and have demonstrated lower VAP rates. We compared the performance of seven SSD ETTs against a non-SSD ETT in preventing aspiration below inflated cuffs. ETTs were positioned vertically in 2 cm diameter cylinders. Four ml of a standard microbial suspension was added above inflated cuffs. After 1 h, aspiration was measured and ETTs demonstrating no leakage were subjected to rotational movement and evaluation over 24 h. Collected aspirated fluid was used to inoculate agar media and incubated aerobically at 37 °C for 24 h. The aspiration rate, volume and number of microorganisms that leaked past the cuff was measured. Experiments were repeated (×10) for each type of ETT, with new ETTs used for each repeat. Best performing ETTs were then tested in five different cylinder diameters (1.6, 1.8, 2.0, 2.2 and 2.4 cm). Experiments were repeated as above using sterile water. Volume and time taken for aspiration past the cuff was measured. Experiments were repeated (×10) for each type of ETT. Results were analysed using non-parametric tests for repeated measures. The PneuX ETT prevented aspiration past the cuff in all experiments. All other ETTs allowed aspiration, with considerable variability in performance. The PneuX ETT was statistically superior in reducing aspiration compared to the SealGuard (p < 0.009), KimVent (p < 0.002), TaperGuard (p < 0.004), Lanz (p < 0.001), ISIS (p < 0.001), SACETT (p < 0.001) and Soft Seal (p < 0.001) ETTs. Of the 4 ETTs tested in differing cylinder sizes, the PneuX significantly reduced aspiration across the range of diameters compared to the SealGuard (p < 0.0001), TaperGuard (p < 0.0001) and KimVent (p < 0.0001) ETTs. ETTs showed substantial variation in fluid
Increasing age and tear size reduce rotator cuff repair healing rate at 1 year.
Rashid, Mustafa S; Cooper, Cushla; Cook, Jonathan; Cooper, David; Dakin, Stephanie G; Snelling, Sarah; Carr, Andrew J
2017-12-01
Background and purpose - There is a need to understand the reasons why a high proportion of rotator cuff repairs fail to heal. Using data from a large randomized clinical trial, we evaluated age and tear size as risk factors for failure of rotator cuff repair. Patients and methods - Between 2007 and 2014, 65 surgeons from 47 hospitals in the National Health Service (NHS) recruited 447 patients with atraumatic rotator cuff tendon tears to the United Kingdom Rotator Cuff Trial (UKUFF) and 256 underwent rotator cuff repair. Cuff integrity was assessed by imaging in 217 patients, at 12 months post-operation. Logistic regression analysis was used to determine the influence of age and intra-operative tear size on healing. Hand dominance, sex, and previous steroid injections were controlled for. Results - The overall healing rate was 122/217 (56%) at 12 months. Healing rate decreased with increasing tear size (small tears 66%, medium tears 68%, large tears 47%, and massive tears 27% healed). The mean age of patients with a healed repair was 61 years compared with 64 years for those with a non-healed repair. Mean age increased with larger tear sizes (small tears 59 years, medium tears 62 years, large tears 64 years, and massive tears 66 years). Increasing age was an independent factor that negatively influenced healing, even after controlling for tear size. Only massive tears were an independent predictor of non-healing, after controlling for age. Interpretation - Although increasing age and larger tear size are both risks for failure of rotator cuff repair healing, age is the dominant risk factor.
[Cuff pressure control at the intersinve care unit: influence of nursing professionals' training].
Velasco Sanz, T R; Ronda Delgado de la Fuente, M; Sánchez de la Ventana, A B; Reyes Merino Martínez, M
2015-01-01
To analyze proper control of endotracheal cuff pressure in an intensive care unit. The specific objective is to verify whether training of nursing professionals improves monitoring endotracheal cuff pressure. the study type is descriptive, observational and retrospective. All patients were admitted to the Critical Unit II of the Clínico San Carlos Hospital between May 2010-November 2011, requiring either a tracheal tube or tracheal cannula. Studied variables were: number of in range measures, number of intubated patients, or with tracheal cannula and register. Four cuts were made on all admitted patients admitted during the study period in order to measure endotracheal cuff pressure. Two cuts were performed before the professional nurses training and the other two cuts after a specific training with respect to endotracheal cuff pressure and Zero pneumonia. There were 74 measurements. The first cut obtained 40.74% of measures in range. In the second cut 61.90% of measures were identified in range. In the third cut, it was found that 85.7% of measures were in range and in the fourth court, it was noted the 89.47% of measures were in range. Monitoring of the endotracheal cuff pressure was inadequate before specific training of professionals. Nursing professionals training facilitates the correct measurement of the endotracheal cuff pressure, which improves patient safety. Copyright © 2013 Elsevier España, S.L.U. y SEEIUC. All rights reserved.
A systematic review of cost-effective treatment of postoperative rotator cuff repairs.
Dickinson, Rebecca N; Kuhn, John E; Bergner, Jamie L; Rizzone, Katherine H
2017-05-01
The Bundled Payments for Care Improvement initiative combines payment of multiple services for episodes of care into 1 bundle. Rotator cuff repair is a likely candidate for future inclusion. The objective of this study was to determine cost-effective, high-quality postoperative rehabilitation dosing and cryotherapy for patients undergoing rotator cuff repair based on systematic review of the literature. Systematic review of level I and level II articles was performed in PubMed, Cochrane Databases, and PEDro. Conference references and bibliographies were also reviewed. For postoperative therapy, keywords included rotator cuff, rotator cuff repair, exercise therapy, exercise, unsupervised, self-care, postoperative period, physical therapy, and physiotherapy; for cryotherapy, keywords included rotator cuff repair, shoulder, cryotherapy, and ice. Five studies compared postoperative outcomes in participants assigned to supervised therapy vs. unsupervised therapy. Three found no difference between groups. One found improved outcomes in supervised therapy. Limitations included that therapies were not consistently defined and significant methodologic issues were present, decreasing the applicability and validity of the results. Five articles examined cryotherapy outcomes in the postoperative shoulder. Two studies showed improved patient outcomes with cryotherapy vs. no cryotherapy; 2 studies showed no decrease in joint space temperatures at 90 minutes but decrease in temperature at 4 to 23 hours postoperatively. One study indicated that an ice bag and Ace bandage might be as effective as continuous, compressive cryotherapy units using patient-reported outcomes. Further studies are needed to determine effective dosing of physical therapy after rotator cuff repair. Cryotherapy is favorable and cost-effective using simple methods for delivery. Copyright © 2017 Journal of Shoulder and Elbow Surgery Board of Trustees. Published by Elsevier Inc. All rights reserved.
Urita, Atsushi; Funakoshi, Tadanao; Horie, Tatsunori; Nishida, Mutsumi; Iwasaki, Norimasa
2017-01-01
Vascularity is the important factor of biologic healing of the repaired tissue. The purpose of this study was to clarify sequential vascular patterns of repaired rotator cuff by suture techniques. We randomized 21 shoulders in 20 patients undergoing arthroscopic rotator cuff repair into 2 groups: transosseous-equivalent repair (TOE group, n = 10) and transosseous repair (TO group, n = 11). Blood flow in 4 regions inside the cuff (lateral articular, lateral bursal, medial articular, and medial bursal), in the knotless suture anchor in the TOE group, and in the bone tunnel in the TO group was measured using contrast-enhanced ultrasound at 1 month, 2 months, 3 months, and 6 months postoperatively. The sequential vascular pattern inside the repaired rotator cuff was different between groups. The blood flow in the lateral articular area at 1 month, 2 months, and 3 months (P = .002, .005, and .025) and that in the lateral bursal area at 2 months (P = .031) in the TO group were significantly greater than those in the TOE group postoperatively. Blood flow was significantly greater for the bone tunnels in the TO group than for the knotless suture anchor in the TOE group at 1 month and 2 months postoperatively (P = .041 and .009). This study clarified that the sequential vascular pattern inside the repaired rotator cuff depends on the suture technique used. Bone tunnels through the footprint may contribute to biologic healing by increasing blood flow in the repaired rotator cuff. Copyright © 2017 Journal of Shoulder and Elbow Surgery Board of Trustees. Published by Elsevier Inc. All rights reserved.
Incidence of retear with double-row versus single-row rotator cuff repair.
Shen, Chong; Tang, Zhi-Hong; Hu, Jun-Zu; Zou, Guo-Yao; Xiao, Rong-Chi
2014-11-01
Rotator cuff tears have a high recurrence rate, even after arthroscopic rotator cuff repair. Although some biomechanical evidence suggests the superiority of the double-row vs the single-row technique, clinical findings regarding these methods have been controversial. The purpose of this study was to determine whether the double-row repair method results in a lower incidence of recurrent tearing compared with the single-row method. Electronic databases were systematically searched to identify reports of randomized, controlled trials (RCTs) comparing single-row with double-row rotator cuff repair. The primary outcome assessed was retear of the repaired cuff. Secondary outcome measures were the American Shoulder and Elbow Surgeons (ASES) shoulder score, the Constant shoulder score, and the University of California, Los Angeles (UCLA) score. Heterogeneity between the included studies was assessed. Six studies involving 428 patients were included in the review. Compared with single-row repair, double-row repair demonstrated a lower retear incidence (risk ratio [RR]=1.71 [95% confidence interval (CI), 1.18-2.49]; P=.005; I(2)=0%) and a reduced incidence of partial-thickness retears (RR=2.16 [95% CI, 1.26-3.71]; P=.005; I(2)=26%). Functional ASES, Constant, and UCLA scores showed no difference between single- and double-row cuff repairs. Use of the double-row technique decreased the incidence of retears, especially partial-thickness retears, compared with the single-row technique. The functional outcome was not significantly different between the 2 techniques. To improve the structural outcome of the repaired rotator cuff, surgeons should use the double-row technique. However, further long-term RCTs on this topic are needed. Copyright 2014, SLACK Incorporated.
Sabetian, Parisa; Popovic, Milos R; Yoo, Paul B
2017-06-01
Differential measurement of efferent and afferent peripheral nerve activity offers a promising means of improving the clinical utility of implantable neuroprostheses. The tripolar nerve cuff electrode has historically served as the gold standard for achieving high signal-to-noise ratios (SNRs) of the recordings. However, the symmetrical geometry of this electrode array (i.e. electrically-shorted side contacts) precludes it from measuring electrical signals that can be used to obtain directional information. In this study, we investigated the feasibility of using a bipolar nerve cuff electrode to achieve high-SNR of peripheral nerve activity. A finite element model was implemented to investigate the effects of electrode design parameters-electrode length, electrode edge length (EEL), and a conductive shielding layer (CSL)-on simulated single fiber action potentials (SFAP) and also artifact noise signals (ANS). Our model revealed that the EEL was particularly effective in increasing the peak-to-peak amplitude of the SFAP (319%) and reducing the common mode ANS (67%) of the bipolar cuff electrode. By adding a CSL to the bipolar cuff electrode, the SNR was found to be 65.2% greater than that of a conventional tripolar cuff electrode. In vivo experiments in anesthetized rats confirmed that a bipolar cuff electrode can achieve a SNR that is 38% greater than that achieved by a conventional tripolar cuff electrode (p < 0.05). The current study showed that bipolar nerve cuff electrodes can be designed to achieve SNR levels that are comparable to that of tripolar configuration. Further work is needed to confirm that these bipolar design parameters can be used to record bi-directional neural activity in a physiological setting.
Zhang, H; Zhu, L; Xu, T; Lang, J H
2016-07-25
To determine the association between simplified pelvic organ prolapse quantification system(S-POP-Q)and the standard pelvic organ prolapse quantification system(POP-Q)in describing pelvic organ prolapse. This was an observational study. From Jan. 2010 to Jan. 2014, 256 subjects with pelvic floor disorder symptoms underwent two exams: a POP-Q exam and a S-POP-Q exam. For the S-POP-Q system, vaginal segments of the exam were defined using points Ba, Bp, C, and D. For the POP-Q system vaginal segments of the exam were defined using points Aa, Ba, Ap, Bp, C, and D. The inter-system consistency between the overall ordinal stages, the anterior vaginal wall stages, the posterior vaginal wall stages, the cervix stages, the posterior fornix or vaginal cuff stages from each two kind of exam were compared. The Kendall tau-b correlation coefficient for overall stage was 0.81, the Kendall tau-b correlation coefficients were 0.81, 0.81, 0.85, 0.88 for the anterior vaginal wall, for the posterior vaginal wall, for the cervix, for the posterior fornix or vaginal cuff, respectively. There is almost perfect association between S-POP-Q and POP-Q in describing pelvic organ prolapse.
Performance of the PneuX System: A Bench Study Comparison With 4 Other Endotracheal Tube Cuffs.
Chenelle, Christopher T; Itagaki, Taiga; Fisher, Daniel F; Berra, Lorenzo; Kacmarek, Robert M
2017-01-01
Cuff design affects microaspiration, a risk factor for pneumonia. We questioned whether the PneuX low-volume fold-free cuff design would prevent cuff leakage and maintain the same tracheal wall pressure as high-volume, low-pressure (HVLP) cuffs. We evaluated 4 HVLP-cuffed endotracheal tubes (ETTs), Hi-Lo (polyvinyl chloride [PVC]), Microcuff (polyurethane [PU]), SealGuard (PU + tapered), and TaperGuard (PVC + tapered), and the PneuX with its dedicated tracheal seal monitor. In Part 1, we determined tracheal wall pressure using each cuff's capacity to support water columns across recommended intracuff pressures. In Part 2, we evaluated the tracheal seal monitor function at recommended settings. In Part 3, we compared leakage volumes of all ETTs during 30 min of simulated mechanical ventilation or during 8 h if no leak occurred. Parts 1 and 3 were performed with/without lubrication and PEEP. In Part 1, PneuX cuffs exerted an average tracheal wall pressure of 27.4 ± 2.4 cm H 2 O at the recommended intracuff pressure of approximately 80 cm H 2 O. Tracheal wall pressure did not differ among HVLP cuffs (19.6 ± 1.4 to 29.5 ± 1.4 cm H 2 O). In Part 2, preinflation intracuff pressure affected the time to obtain tracheal seal monitor pressure attainment (P < .01). The tracheal seal monitor generated average calculated tracheal wall pressure of 33.4 ± 1.2 cm H 2 O. In Part 3, PneuX ETT showed no leak across 8 h for all trials. Overall, leakage volume was lower with PU (P < .01) and PneuX (P < .01) than with PVC cuffs, regardless of shape, and lower with lubrication and/or PEEP (all P < .01). In each HVLP cuff, lubrication alone eliminated leak at an intracuff pressure of ≤30 cm H 2 O. The PneuX cuff generally exerted acceptable tracheal wall pressure, but the tracheal wall pressure monitor allowed pressures exceeding 30 cm H 2 O in some trials and was the only ETT to prevent leak in all tests. For HVLP cuffs, leak was reduced by PU and PEEP and eliminated by lubrication
The cost-effectiveness of single-row compared with double-row arthroscopic rotator cuff repair.
Genuario, James W; Donegan, Ryan P; Hamman, Daniel; Bell, John-Erik; Boublik, Martin; Schlegel, Theodore; Tosteson, Anna N A
2012-08-01
Interest in double-row techniques for arthroscopic rotator cuff repair has increased over the last several years, presumably because of a combination of literature demonstrating superior biomechanical characteristics and recent improvements in instrumentation and technique. As a result of the increasing focus on value-based health-care delivery, orthopaedic surgeons must understand the cost implications of this practice. The purpose of this study was to examine the cost-effectiveness of double-row arthroscopic rotator cuff repair compared with traditional single-row repair. A decision-analytic model was constructed to assess the cost-effectiveness of double-row arthroscopic rotator cuff repair compared with single-row repair on the basis of the cost per quality-adjusted life year gained. Two cohorts of patients (one with a tear of <3 cm and the other with a tear of ≥3 cm) were evaluated. Probabilities for retear and persistent symptoms, health utilities for the particular health states, and the direct costs for rotator cuff repair were derived from the orthopaedic literature and institutional data. The incremental cost-effectiveness ratio for double-row compared with single-row arthroscopic rotator cuff repair was $571,500 for rotator cuff tears of <3 cm and $460,200 for rotator cuff tears of ≥3 cm. The rate of radiographic or symptomatic retear alone did not influence cost-effectiveness results. If the increase in the cost of double-row repair was less than $287 for small or moderate tears and less than $352 for large or massive tears compared with the cost of single-row repair, then double-row repair would represent a cost-effective surgical alternative. On the basis of currently available data, double-row rotator cuff repair is not cost-effective for any size rotator cuff tears. However, variability in the values for costs and probability of retear can have a profound effect on the results of the model and may create an environment in which double-row repair
Rosero, Eric B; Ozayar, Esra; Eslava-Schmalbach, Javier; Minhajuddin, Abu; Joshi, Girish P
2017-11-17
Tracheal tube cuff pressures exceeding the perfusion pressures of the tracheal mucosa have been associated with complications such as sore throat, tracheal mucosa ulcers, tracheal rupture, and subglottic stenosis. Despite appropriate inflation, many factors can increase the tracheal cuff pressure during mechanical ventilation. This prospective observational cohort study was designed to test the hypothesis that during a clinical model of decreasing respiratory compliance, the pressure within the endotracheal tube cuff will rise in direct relationship to increases in the airway pressures. Twenty-eight adult obese patients (BMI ≥30 kg/m) scheduled for elective laparoscopic gynecologic procedures were enrolled. All patients received general anesthesia utilizing endotracheal tubes with low-pressure high-volume cuffs. After baseline adjustment of the cuff pressure to 25 cm H2O, the airway pressures and endotracheal cuff pressures were continuously measured using pressure transducers connected to the anesthesia circuit and cuff pilot, respectively. Data on cuff and airway pressures, mechanical ventilation parameters, intraabdominal pressures, and degree of surgical table inclination were collected throughout the anesthetic procedure. General linear regression models with fixed and random effects were fit to assess the effect of increases in airway pressures on cuff pressure, after adjusting for covariates and the clustered structure of the data. The mean (standard deviation) age and body mass index were 42.2 (8.8) years and 37.7 (5.1) kg/m, respectively. After tracheal intubation, the cuffs were overinflated (ie, intracuff pressures >30 cm H2O) in 89% of patients. The cuff pressures significantly changed after concomitant variations in the airway pressures from a mean (standard error) value of 29.6 (1.30) cm H2O before peritoneal insufflations, to 35.6 (0.68) cm H2O after peritoneal insufflation, and to 27.8 (0.79) cm H2O after peritoneal deflation (P < .0001). The
Bertholon, Pierre; Reynard, Pierre; Lelonge, Yann; Peyron, Roland; Vassal, François; Karkas, Alexandre
2018-02-01
Hearing of eyeball movements has been reported in superior semicircular canal dehiscence (SSCD), but not hearing of eyelid movements. Our main objective was to report the hearing of eyeball and/or eyelid movements in unilateral SSCD. Our secondary objective was to access its specificity to SSCD and discuss the underlying mechanism. Six patients with SSCD who could hear their eyeball and/or eyelid movements were retrospectively reviewed. With the aim of comparisons, eight patients with an enlarged vestibular aqueduct (EVA), who share the same mechanism of an abnormal third window, were questioned on their ability to hear their eyeball and/or eyelid movements. Three patients with SSCD could hear both their eyeball and eyelid movements as a soft low-pitch friction sound. Two patients with SSCD could hear only their eyelid movements, one of whom after the surgery of a traumatic chronic subdural hematoma. The latter remarked that every gently tapping on the skin covering the burr-hole was heard in his dehiscent ear as the sound produced when banging on a drum, in keeping with a direct transmission of the sound to the inner ear via the cerebrospinal fluid. One patient with SSCD, who could hear only his eyeball movements, had other disabling symptoms deserving operation through a middle fossa approach with an immediate relief of his symptoms. None of the eight patients with EVA could hear his/her eyeball or eyelid movements. Hearing of eyeball and/or eyelid movements is highly suggestive of a SSCD and do not seem to occur in EVA. In case of radiological SSCD, clinicians should search for hearing of eyeball and/or eyelid movements providing arguments for a symptomatic dehiscence. The underlying mechanism is discussed particularly the role of a cerebrospinal fluid transmission.
Zhang, X A; Li, Y; Dai, C F
2016-02-01
The objective of this study is to investigate the clinical manifestations of the superior semicircular canal dehiscence syndrome(SSCDS) and the treatment strategies. Data from 20 cases diagnosed with SSCDS from September 2004 to December 2014 were retrospectively analyzed in this study. The clinical presentations including symptoms, signs, audiological and vestibular function examination, and their imaging characteristics and treatment strategies were reviewed. All of the patients demonstrated variable degree of vertigo. Four patients could not tolerate the environmental noise. Autophony was noted in nine cases, among whom, two patients could feel their eye movements and heart beat, one patient could feel his footstep, one patient couldn't endure the singing by himself. Slow component vertical tortional eye movement away from the effected eye were observed in twelve patients when loud noise was given or middle ear or intracranial pressure increased. Head movement was induced by loud noise in one case. Ten patients presented with low frequency hearing loss. One case was concomitance with chronic otitis media and demonstrated severe sensorineural hearing loss. Nine patients demonstrated normal hearing. Decreased thresholds were showed by VEMP examination in six cases. Variable bone defect overlying in the SSCDS was confirmed by CT scans in all of the cases. The surgical repair of the superior semicircular canal dehiscence was performed through the middle cranial fossa approach in three cases and mastoid approach in two cases. The dizziness and the autophony were significantly alleviated after surgery. The clinical manifestations of SSCDS mainly demonstrate dizziness, autophony and loss of low frequency hearing. Treatment strategies are mainly composed of avoidance of environmental noise and shouting voice of the patients themselves. Surgical repair of the superior semicircular canal dehiscence was proposed to conduct, either through the middle cranial fossa approach
Robertson, Catherine M; Chen, Christopher T; Shindle, Michael K; Cordasco, Frank A; Rodeo, Scott A; Warren, Russell F
2012-09-01
Despite improvements in arthroscopic rotator cuff repair technique and technology, a significant rate of failed tendon healing persists. Improving the biology of rotator cuff repairs may be an important focus to decrease this failure rate. The objective of this study was to determine the mRNA biomarkers and histological characteristics of repaired rotator cuffs that healed or developed persistent defects as determined by postoperative ultrasound. Increased synovial inflammation and tendon degeneration at the time of surgery are correlated with the failed healing of rotator cuff tendons. Case-control study; Level of evidence, 3. Biopsy specimens from the subscapularis tendon, supraspinatus tendon, glenohumeral synovium, and subacromial bursa of 35 patients undergoing arthroscopic rotator cuff repair were taken at the time of surgery. Expression of proinflammatory cytokines, tissue remodeling genes, and angiogenesis factors was evaluated by quantitative real-time polymerase chain reaction. Histological characteristics of the affected tissue were also assessed. Postoperative (>6 months) ultrasound was used to evaluate the healing of the rotator cuff. General linear modeling with selected mRNA biomarkers was used to predict rotator cuff healing. Thirty patients completed all analyses, of which 7 patients (23%) had failed healing of the rotator cuff. No differences in demographic data were found between the defect and healed groups. American Shoulder and Elbow Surgeons shoulder scores collected at baseline and follow-up showed improvement in both groups, but there was no significant difference between groups. Increased expression of matrix metalloproteinase 1 (MMP-1) and MMP-9 was found in the supraspinatus tendon in the defect group versus the healed group (P = .006 and .02, respectively). Similar upregulation of MMP-9 was also found in the subscapularis tendon of the defect group (P = .001), which was consistent with the loss of collagen organization as determined by
Huang, Shih-Wei; Wang, Wei-Te; Chou, Lin-Chuan; Liou, Tsan-Hon; Chen, Yi-Wen; Lin, Hui-Wen
Rotator cuff tears are the most common cause of shoulder disability in people older than 50years, and surgical intervention is usually required for restoring functioning. However, in patients undergoing rotator cuff repair surgery, patients with DM had poorer functional outcomes than those without DM, and hence, DM is one of the possible risks factor for rotator cut off tear. The aim of this population-based study was to investigate the relationship between DM and the risk of rotator cuff tear in patients receiving rotator cuff repair surgery. In this retrospective longitudinal population-based 7-year cohort study, we investigated the risk of rotator cuff repair surgery in patients with DM. We performed a case-control matched analysis by using data from the Taiwan Longitudinal Health Insurance Database 2005. Patients were enrolled on the basis of the International Classification of Diseases, Ninth Revision, Clinical Modification diagnostic codes for DM between January 1, 2004, and December 31, 2007. The prevalence and the adjusted hazard ratios (HRs) of a rotator cuff repair surgery in patients with and without DM were estimated according to the Cox proportional hazard regression analysis using the frailty model. The DM and non-DM cohorts comprised 58,652 patients with DM and 117,304 (1:2) patients without DM after matching for age and sex. The incidence of rotator cuff repair surgery was 41 per 100,000 and 26 per 100,000 person-years in the DM and non-DM cohorts, respectively. The HR of rotator cuff repair surgery during the follow-up period was 1.56 (95% confidence interval [CI] 1.25-1.93, p<0.001) for patients with DM. After adjustment for covariates, the adjusted HR of rotator cuff repair surgery was 1.33 (95% CI, 1.05-1.68, p<0.001) in the DM cohort. DM is an independent risk factor for rotator cuff tear repair surgery. Copyright © 2016 Elsevier Inc. All rights reserved.
[Aerobic vaginitis--diagnostic problems and treatment].
Romanik, Małgorzata; Wojciechowska-Wieja, Anna; Martirosian, Gayane
2007-06-01
The diagnostic criteria and treatment of aerobic vaginitis--AV--have been summarized in this review. An expansion of mixed aerobic microflora, especially Group B Streptococcus--GBS, Escherichia coli--E. coli, Enterococcus spp., and the development of inflammation of the vaginal mucous membrane due to a decreasing amount of Lactobacillus spp., have been observed in women with AV. Disruptions of the vaginal ecosystem during AV cause an increase in pH to >6, a decrease in lactates concentration and an increase in proinflammatory cytokines concentration in vaginal discharge. An optimal treatment scheme for AV, which includes antibacterial agents and simultaneously normalizes the vaginal ecosystem, has not been established until today.
Treatment of Partial Rotator Cuff Tear with Ultrasound-guided Platelet-rich Plasma.
Sengodan, Vetrivel Chezian; Kurian, Sajith; Ramasamy, Raghupathy
2017-01-01
The treatment of symptomatic partial rotator cuff tear has presented substantial challenge to orthopaedic surgeons as it can vary from conservative to surgical repair. Researches have established the influence of platelet rich plasma in healing damaged tissue. Currently very few data are available regarding the evidence of clinical and radiological outcome of partial rotator cuff tear treated with ultrasound guided platelet rich plasma injection in English literature. 20 patients with symptomatic partial rotator cuff tears were treated with ultrasound guided platelet rich plasma injection. Before and after the injection of platelet rich plasma scoring was done with visual analogue score, Constant shoulder score, and UCLA shoulder score at 8 weeks and third month. A review ultrasound was performed 8 weeks after platelet rich plasma injection to assess the rotator cuff status. Our study showed statistically significant improvements in 17 patients in VAS pain score, constant shoulder score and UCLA shoulder score. No significant changes in ROM were noted when matched to the contra-lateral side ( P < 0.001) at the 3 month follow-up. The study also showed good healing on radiological evaluation with ultrasonogram 8 weeks after platelet rich plasma injection. Ultrasound guided platelet rich plasma injection for partial rotator cuff tears is an effective procedure that leads to significant decrease in pain, improvement in shoulder functions, much cost-effective and less problematic compared to a surgical treatment.
Vitamin D and the immunomodulation of rotator cuff injury
Dougherty, Kaitlin A; Dilisio, Matthew F; Agrawal, Devendra K
2016-01-01
Tendon-to-bone healing after rotator cuff repair surgery has a failure rate of 20%–94%. There has been a recent interest to determine the factors that act as determinants between successful and unsuccessful rotator cuff repair. Vitamin D level in patients is one of the factors that have been linked to bone and muscle proliferation and healing, and it may have an effect on tendon-to-bone healing. The purpose of this article is to critically review relevant published research that relates to the effect of vitamin D on rotator cuff tears and subsequent healing. A review of the literature was conducted to identify all studies that investigate the relationship between vitamin D and tendon healing, in addition to its mechanism of action. The data were then analyzed in order to summarize what is currently known about vitamin D, rotator cuff pathology, and tendon-to-bone healing. The activated metabolite of vitamin D, 1α,25-dihydroxyvitamin D3, affects osteoblast proliferation and differentiation. Likewise, vitamin D plays a significant role in the tendon-to-bone healing process by increasing the bone mineral density and strengthening the skeletal muscles. The 1α,25-dihydroxyvitamin D3 binds to vitamin D receptors on myocytes to stimulate growth and proliferation. The form of vitamin D produced by the liver, calcifediol, is a key initiator of the myocyte healing process by moving phosphate into myocytes, which improves function and metabolism. Investigation into the effect of vitamin D on tendons has been sparse, but limited studies have been promising. Matrix metalloproteinases play an active role in remodeling the extracellular matrix (ECM) of tendons, particularly deleterious remodeling of the collagen fibers. Also, the levels of transforming growth factor-β3 positively influence the success of the surgery for rotator cuff repair. In the tendon-to-bone healing process, vitamin D has been shown to successfully influence bone and muscle healing, but more research is
Cerciello, Simone; Monk, Andrew Paul; Visonà, Enrico; Carbone, Stefano; Edwards, Thomas Bradley; Maffulli, Nicola; Walch, Gilles
2017-07-01
Secondary cuff failure after shoulder replacement is disabling and often requires additional surgery. Increased critical shoulder angle (CSA) has been found in patients with cuff tear compared to normal subjects. The interobserver reliability of the CSA and the relationship between CSA and symptomatic secondary cuff failure after shoulder replacement were investigated. Nineteen patients with symptomatic cuff failure after anatomic shoulder replacement (mean FU 45 months) were compared to a control group of 29 patients showing no signs of symptomatic cuff failure (mean FU 105.7 months). The CSA was measured by two blinded surgeons at a mean follow-up of 45 and 105.7 months, respectively. Inter-observer reliability was calculated. The mean CSA in the study group in neutral, internal and external rotations were 33°, 34° and 34°, respectively. Corresponding values in the control group were 32°, 32° and 32°. The interclass correlation coefficient for the whole population between the two examiners were 0.956 (P < 0.01), 0.964 (P < 0.01) and 0.955 (P < 0.01), respectively. There were no significant differences of CSA values between patients who had undergone shoulder replacement and experienced late cuff failure and those in whom the same procedure had been successful. A good inter-observer reliability was found for the CSA method.
Livesey, Michael; Horneff, John G; Sholder, Daniel; Lazarus, Mark; Williams, Gerald; Namdari, Surena
2018-05-01
A well-functioning rotator cuff is necessary for successful anatomic total shoulder arthroplasty (TSA). This study evaluated patients who underwent concomitant TSA and rotator cuff repair (RCR) for functional outcomes, revision rates, and predictors of poor results. Retrospective chart review was conducted to identify patients who underwent TSA and RCR. Demographic data, rotator cuff tear and RCR characteristics, range of motion, and radiographs were recorded. Minimum 2-year functional outcomes were obtained. Predictors of reoperation and/or poor clinical results were determined. Forty-five patients met inclusion criteria (22 high-grade partial-thickness and 23 full-thickness tears). Fourteen (31%) patients were labeled as having a poor result; 8 (18%) patients required reoperation. There was a significant difference between the acromiohumeral interval preoperatively and immediately postoperatively (P=.013). However, at maximum radiographic follow-up, the acromiohumeral interval was not significantly different from preoperative values (P=.86). Patients with a preoperative acromiohumeral interval of less than 8 mm had an increased rate of cuff-related reoperation (P=.003). Although concomitant TSA and RCR is a reasonable consideration, 31% of patients had a poor clinical result. An acromiohumeral interval of less than 8 mm was a predictor of cuff-related reoperation and may be an indication to consider reverse arthroplasty in the setting of joint arthrosis with a rotator cuff tear. [Orthopedics. 2018; 41(3):e334-e339.]. Copyright 2018, SLACK Incorporated.
Functional evaluation of patient after arthroscopic repair of rotator cuff tear.
Kumar, Rohit; Jadhav, Umesh
2014-06-01
Rotator cuff tear is a common problem either after trauma or after degenerative tear in old age group. Arthroscopic repair is the current concept of rotator cuff repair. Here, we are trying to evaluate the functional outcome after arthroscopic repair of full thickness rotator cuff tear (single row) in Indian population. Twenty five patients (14 males and 11 females) who underwent arthroscopic repair of full thickness rotator cuff tear at a single institution were included in the study. Postoperatively patient's shoulder was rated according to UCLA score, pain was graded according to the visual analog score. The range of motion was analysed and documented. The mean age of the patients were 50.48 years. The preoperative VAS score mode was 7 and post operative VAS was 1 (p value <0.001). The UCLA grading was good in 80% (n = 20), fair in 12% (n = 3), excellent in 8% (n = 2) and poor results were seen in none of the patients. The mean UCLA improved from a score of 15.84 to 30.28 with a p value <0.001. Mean postoperative forward flexion was 161.6°, mean abduction was 147.6° and mean external rotation was 45.4°. Arthroscopic repair is a good procedure for full thickness rotator cuff tear with minimal complications. The newer double row repair claims to be biomechanically superior with faster healing rates without functional advantages, hence we used a single row repair considering the Indian population and the cost effectiveness of the surgery with good to excellent results.
Comparison of joint torque evoked with monopolar and tripolar-cuff electrodes.
Tarler, Matthew D; Mortimer, J Thomas
2003-09-01
Using a self-sizing spiral-cuff electrode placed on the sciatic nerve of the cat, the joint torque evoked with stimulation applied to contacts in a monopolar configuration was judged to be the same as the torque evoked by stimulation applied to contacts in a tripolar configuration. Experiments were carried out in six acute cat preparations. In each experiment, a 12-contact electrode was placed on the sciatic nerve and used to effect both the monopolar and tripolar electrode configurations. The ankle torque produced by electrically evoked isometric muscle contraction was measured in three dimensions: plantar flexion, internal rotation, and inversion. Based on the recorded ankle torque, qualitative and quantitative comparisons were performed to determine if any significant difference existed in the pattern or order in which motor nerve fibers were recruited. No significant difference was found at a 98% confidence interval in either the recruitment properties or the repeatability of the monopolar and tripolar configurations. Further, isolated activation of single fascicles within the sciatic nerve was observed. Once nerve fibers in a fascicle were activated, recruitment of that fascicle was modulated over the full range before "spill-over" excitation occurred in neighboring fascicles. These results indicate that a four contact, monopolar nerve-cuff electrode is a viable substitute for a 12 contact, tripolar nerve-cuff electrode. The results of this study are also consistent with the hypothesis that multicontact self-sizing spiral-cuff electrodes can be used in motor prostheses to provide selective control of many muscles. These findings should also apply to other neuroprostheses employing-cuff electrodes on nerve trunks.
The 50 Most Cited Articles in Rotator Cuff Repair Research.
Kraeutler, Matthew J; Freedman, Kevin B; MacLeod, Robert A; Schrock, John B; Tjoumakaris, Fotios P; McCarty, Eric C
2016-11-01
Analysis of the number of citations within a given specialty provides information on the classic publications of that specialty. The goals of this study were to identify the 50 most cited articles on rotator cuff repair and to analyze various characteristics of these articles. The ISI Web of Science (Thomson Reuters, Philadelphia, Pennsylvania) was used to conduct a search for the term rotator cuff repair. The 50 most cited articles were retrieved, and the following objective characteristics of each article were recorded: number of times cited, citation density, journal, country of origin, and language. The following subjective characteristics of each article were also recorded: article type (clinical vs basic science), article subtype, and level of evidence for clinical articles. Of the 50 most cited articles on rotator cuff repair, the number of citations ranged from 138 to 677 (mean, 232±133 citations) and citation density ranged from 3.8 to 53.5 citations per year (mean, 16.9±9.2 citations per year). The articles were published between 1974 and 2011, with most of the articles published in the 2000s (29 articles), followed by the 1990s (16 articles). The articles originated from 8 countries, with the United States accounting for 30 articles (60%). Overall, 66% of the articles were clinical and 34% were basic science. The most common article subtype was the clinical case series (48%). Of the 33 clinical articles, 24 (73%) were level IV. Among the 50 most cited articles on rotator cuff repair, the case series was the most common article subtype, showing the effect that publication of preliminary outcomes and new surgical techniques has had on surgeons performing rotator cuff repair. [Orthopedics. 2016; 39(6):e1045-e1051.]. Copyright 2016, SLACK Incorporated.
Ultrasound dimensions of the rotator cuff in young healthy adults.
Karthikeyan, Shanmugam; Rai, Santosh B; Parsons, Helen; Drew, Steve; Smith, Christopher D; Griffin, Damian R
2014-08-01
No studies have looked at the rotator cuff dimensions in the young healthy population using ultrasonography. Our aim is to define the ultrasound dimensions of the rotator cuff in the healthy young adult population and explore correlations with other patient characteristics. Thirty male and 30 female healthy volunteers (aged 18-40 years), with no shoulder problems, underwent ultrasound assessment of both shoulders by a musculoskeletal radiologist. The dimensions of the rotator cuff, deltoid, and biceps were measured in a standardized manner. A total of 120 shoulders were scanned. The mean maximum width of the supraspinatus footprint was 14.9 mm in men and 13.5 mm in women (P < .001). The mean thickness of the supraspinatus tendon was 4.9 mm in women and 5.6 mm in men. The mean thickness of the subscapularis was 4.4 in men and 3.8 mm in women and for the infraspinatus was 4.9 mm in men and 4.4 mm in women. There was no correlation between height, weight, biceps, or deltoid thickness with any tendon measurements. Apart from supraspinatus tendon thickness, the difference between dominant and nondominant shoulders in the same sex was not significant for any other tendon dimensions. This study has defined the dimensions of the rotator cuff in the young healthy adult, which has not been previously published. This is important for the documentation of normal ultrasound anatomy of the rotator cuff and also demonstrates that the asymptomatic contralateral shoulder can and should be used to estimate the expected dimensions. Copyright © 2014 Journal of Shoulder and Elbow Surgery Board of Trustees. Published by Mosby, Inc. All rights reserved.
Increasing age and tear size reduce rotator cuff repair healing rate at 1 year
Rashid, Mustafa S; Cooper, Cushla; Cook, Jonathan; Cooper, David; Dakin, Stephanie G; Snelling, Sarah; Carr, Andrew J
2017-01-01
Background and purpose — There is a need to understand the reasons why a high proportion of rotator cuff repairs fail to heal. Using data from a large randomized clinical trial, we evaluated age and tear size as risk factors for failure of rotator cuff repair. Patients and methods — Between 2007 and 2014, 65 surgeons from 47 hospitals in the National Health Service (NHS) recruited 447 patients with atraumatic rotator cuff tendon tears to the United Kingdom Rotator Cuff Trial (UKUFF) and 256 underwent rotator cuff repair. Cuff integrity was assessed by imaging in 217 patients, at 12 months post-operation. Logistic regression analysis was used to determine the influence of age and intra-operative tear size on healing. Hand dominance, sex, and previous steroid injections were controlled for. Results — The overall healing rate was 122/217 (56%) at 12 months. Healing rate decreased with increasing tear size (small tears 66%, medium tears 68%, large tears 47%, and massive tears 27% healed). The mean age of patients with a healed repair was 61 years compared with 64 years for those with a non-healed repair. Mean age increased with larger tear sizes (small tears 59 years, medium tears 62 years, large tears 64 years, and massive tears 66 years). Increasing age was an independent factor that negatively influenced healing, even after controlling for tear size. Only massive tears were an independent predictor of non-healing, after controlling for age. Interpretation — Although increasing age and larger tear size are both risks for failure of rotator cuff repair healing, age is the dominant risk factor. PMID:28880113
Effects of age and pathology on shear wave speed of the human rotator cuff.
Baumer, Timothy G; Dischler, Jack; Davis, Leah; Labyed, Yassin; Siegal, Daniel S; van Holsbeeck, Marnix; Moutzouros, Vasilios; Bey, Michael J
2018-01-01
Rotator cuff tears are common and often repaired surgically, but post-operative repair tissue healing, and shoulder function can be unpredictable. Tear chronicity is believed to influence clinical outcomes, but conventional clinical approaches for assessing tear chronicity are subjective. Shear wave elastography (SWE) is a promising technique for assessing soft tissue via estimates of shear wave speed (SWS), but this technique has not been used extensively on the rotator cuff. Specifically, the effects of age and pathology on rotator cuff SWS are not well known. The objectives of this study were to assess the association between SWS and age in healthy, asymptomatic subjects, and to compare measures of SWS between patients with a rotator cuff tear and healthy, asymptomatic subjects. SWE images of the supraspinatus muscle and intramuscular tendon were acquired from 19 asymptomatic subjects and 11 patients with a rotator cuff tear. Images were acquired with the supraspinatus under passive and active (i.e., minimal activation) conditions. Mean SWS was positively associated with age in the supraspinatus muscle and tendon under passive and active conditions (p ≤ 0.049). Compared to asymptomatic subjects, patients had a lower mean SWS in their muscle and tendon under active conditions (p ≤ 0.024), but no differences were detected under passive conditions (p ≥ 0.783). These findings identify the influences of age and pathology on SWS in the rotator cuff. These preliminary findings are an important step toward evaluating the clinical utility of SWE for assessing rotator cuff pathology. © 2017 Orthopaedic Research Society. Published by Wiley Periodicals, Inc. J Orthop Res 36:282-288, 2018. © 2017 Orthopaedic Research Society. Published by Wiley Periodicals, Inc.
Medialized repair for retracted rotator cuff tears.
Kim, Young-Kyu; Jung, Kyu-Hak; Won, Jun-Sung; Cho, Seung-Hyun
2017-08-01
The purpose of this study was to evaluate the functional outcomes of medialized rotator cuff repair and the continuity of repaired tendon in chronic retracted rotator cuff tears. Thirty-five consecutive patients were selected from 153 cases that underwent arthroscopic rotator cuff repair for more than medium-sized posterosuperior rotator cuff tears between July 2009 and July 2012 performed with the medialized repair. All cases were available for at least 2 years of postoperative follow-up. The visual analog scale of pain, muscle strength, Constant score, American Shoulder and Elbow Surgeons (ASES) score, and University of California-Los Angeles score were evaluated. At the final follow-up, all clinical outcomes were significantly improved. The visual analog scale score for pain improved from 6 ± 1 preoperatively to 2 ± 1 postoperatively. The range of motion increased from preoperatively to postoperatively: active forward elevation, from 134° ± 49° to 150° ± 16°; active external rotation at the side, from 47° ± 15° to 55° ± 10°; and active internal rotation, from L3 to L1. The shoulder score also improved: Constant score, from 53.5 ± 16.7 to 79 ± 10; American Shoulder and Elbow Surgeons score, from 51 ± 15 to 82 ± 8; and University of California-Los Angeles score, from 14 ± 4 to 28 ± 4. The retear cases at the final follow-up were 6 (17%). Medialized repair may be useful in cases in which anatomic bone-to-tendon repair would be difficult because of the excessive tension of the repaired tendon and a torn tendon that does not reach the anatomic insertion. Copyright © 2016 Journal of Shoulder and Elbow Surgery Board of Trustees. Published by Elsevier Inc. All rights reserved.
NASA Astrophysics Data System (ADS)
Sabetian, Parisa; Popovic, Milos R.; Yoo, Paul B.
2017-06-01
Objective. Differential measurement of efferent and afferent peripheral nerve activity offers a promising means of improving the clinical utility of implantable neuroprostheses. The tripolar nerve cuff electrode has historically served as the gold standard for achieving high signal-to-noise ratios (SNRs) of the recordings. However, the symmetrical geometry of this electrode array (i.e. electrically-shorted side contacts) precludes it from measuring electrical signals that can be used to obtain directional information. In this study, we investigated the feasibility of using a bipolar nerve cuff electrode to achieve high-SNR of peripheral nerve activity. Approach. A finite element model was implemented to investigate the effects of electrode design parameters—electrode length, electrode edge length (EEL), and a conductive shielding layer (CSL)—on simulated single fiber action potentials (SFAP) and also artifact noise signals (ANS). Main results. Our model revealed that the EEL was particularly effective in increasing the peak-to-peak amplitude of the SFAP (319%) and reducing the common mode ANS (67%) of the bipolar cuff electrode. By adding a CSL to the bipolar cuff electrode, the SNR was found to be 65.2% greater than that of a conventional tripolar cuff electrode. In vivo experiments in anesthetized rats confirmed that a bipolar cuff electrode can achieve a SNR that is 38% greater than that achieved by a conventional tripolar cuff electrode (p < 0.05). Significance. The current study showed that bipolar nerve cuff electrodes can be designed to achieve SNR levels that are comparable to that of tripolar configuration. Further work is needed to confirm that these bipolar design parameters can be used to record bi-directional neural activity in a physiological setting.
Schwarz, Frank; Sager, Martin; Kadelka, Ines; Ferrari, Daniel; Becker, Jürgen
2010-05-01
The aim of the present study was to compare bone regeneration in dehiscence-type defects at titanium implants with chemically modified sandblasted/acid-etched (modSLA) or dual acid-etched surfaces with a calcium phosphate nanometre particle modification (DCD/CaP). Buccal dehiscence-type defects were surgically created following implant site preparation in both the upper and the lower jaws of 12 fox hounds. Both types of implants were randomly allocated in a split-mouth design and left to heal in a submerged position for 2 and 8 weeks. Dissected blocks were processed for histomorphometrical analysis [e.g. new bone height (NBH), percentage of bone-to-implant contact (BIC), area of new bone fill (BF), and area of mineralized tissue (MT) within BF]. At 2 and 8 weeks, both groups revealed comparable mean BF (2.3+/-0.6 to 2.5+/-0.6 mm(2)versus 2.0+/-0.6 to 1.4+/-0.5 mm(2)) and MT (31.1+/-14.3-83.2+/-8.2%versus 38.9+/-15.9-84.4+/-6.3%) values. However, modSLA implants revealed significantly higher mean NBH (2.4+/-0.8 to 3.6+/-0.3 mm versus 0.9+/-0.8 to 1.8+/-1.4 mm) and BIC (53.3+/-11.3-79.5+/-6.6%versus 19.3+/-16.4-47.2+/-30.7%) values than DCD/CaP implants. ModSLA implants may have a higher potential to support osseointegration in dehiscence-type defects than DCD/CaP implants.
Biomechanical and functional variation in rat sciatic nerve following cuff electrode implantation
2014-01-01
Background Nerve cuff electrodes are commonly and successfully used for stimulating peripheral nerves. On the other hand, they occasionally induce functional and morphological changes following chronic implantation, for reasons not always clear. We hypothesize that restriction of nerve mobility due to cuff implantation may alter nerve conduction. Methods We quantified acute changes in nerve-muscle electrophysiology, using electromyography, and nerve kinematics in anesthetized Sprague Dawley rat sciatic nerves during controlled hindlimb joint movement. We compared electrophysiological and biomechanical response in uncuffed nerves and those secured within a cuff electrode using analysis of variance (ANOVA) and regression analysis. Results Tethering resulting from cuff implantation resulted in altered nerve strain and a complex biomechanical environment during joint movement. Coincident with biomechanical changes, electromyography revealed significantly increased variability in the response of conduction latency and amplitude in cuffed, but not free, nerves following joint movement. Conclusion Our findings emphasize the importance of the mechanical interface between peripheral nerves and their devices on neurophysiological performance. This work has implications for nerve device design, implantation, and prediction of long-term efficacy. PMID:24758405
An epidemiological study of rotator cuff pathology using The Health Improvement Network database.
White, J J E; Titchener, A G; Fakis, A; Tambe, A A; Hubbard, R B; Clark, D I
2014-03-01
Little is known about the incidence of rotator cuff pathology or its demographic associations in the general population. We undertook a large epidemiological study of rotator cuff pathology in the United Kingdom using The Health Improvement Network (THIN) database. The incidence of rotator cuff pathology was 87 per 100,000 person-years. It was more common in women than in men (90 cases per 100,000 person-years in women and 83 per 100,000 person-years in men; p < 0.001). The highest incidence of 198 per 100,000 person-years was found in those aged between 55 and 59 years. The regional distribution of incidence demonstrated an even spread across 13 UK health authorities except Wales, where the incidence was significantly higher (122 per 100,000 person-years; p < 0.001). The lowest socioeconomic group had the highest incidence (98 per 100,000 person-years). The incidence has risen fourfold since 1987 and as of 2006 shows no signs of plateauing. This study represents the largest general population study of rotator cuff pathology reported to date. The results obtained provide an enhanced appreciation of the epidemiology of rotator cuff pathology and may help to direct future upper limb orthopaedic services.
Effects of the choice of reference on the selectivity of a multi-contact nerve cuff electrode.
Koh, Ryan G L; Zariffa, Jose
2016-08-01
Tripolar referencing is typically used in nerve cuff electrode recordings due to its ability to maximize the signal-to-noise ratio of contacts at the centre, but this may not be the optimal choice for a multi-contact nerve cuff consisting of contacts in off-centre rings. We conducted a simulation study to compare the effects of 3 different reference types on the recording selectivity of a multi-contact nerve cuff: the tripolar reference (TPR), common average reference (CAR), and multiple tripolar references based on consecutive groups of 3 rings (cTPR). For this purpose, we introduce a novel measure called the contact information metric (CIM). Selectivity was tested in 2 noise settings, one in which white Gaussian noise was added inside the nerve cuff electrode and the other in which electromyogram (EMG) noise was added outside the nerve cuff electrode. The mean CIMs values calculated for the best 8 contacts were 3.42±6.25, 2.70±3.37, and 3.65±1.90 for the TPR, the CAR and the cTPR, respectively, in the case of EMG noise added outside the nerve cuff electrode. This study shows that the use of cTPR reference is the optimal choice for selectivity when using a multi-contact nerve cuff electrode which contains off-centre rings.
Komasawa, Nobuyasu; Mihara, Ryosuke; Imagawa, Kentaro; Hattori, Kazuo; Minami, Toshiaki
2015-01-01
The present study compared changes in cuff pressure by head and neck position between high-volume low-pressure (HVLP) and taper-shaped (taper) cuffs in a prospective randomized clinical trial. Methods. Forty patients were intubated using tracheal tubes with either HVLP (n = 20; HVLP group) or taper-shaped (n = 20; Taper group) cuffs. Initial cuff pressure was adjusted to 15, 20, or 25 cmH2O in the neutral position. Cuff pressure was evaluated after changing the head and neck positions to flexion, extension, and rotation. Results. Cuff pressure significantly increased with flexion in both HVLP and Taper groups at all initial cuff pressures. It significantly increased with extension in the HVLP group, but not in the Taper group. Cuff pressure did not significantly differ with rotation in either group and was significantly smaller in the Taper group during flexion and extension than in the HVLP group, regardless of initial cuff pressure. Conclusion. Cuff pressure changes with head and neck flexion and extension were smaller in the Taper group than in the HVLP group. Our results highlight the potential for taper cuffs to prevent excessive cuff pressure increases with positional changes in the head and neck. This trial is registered with UMIN000016119. PMID:26509152
The Burden of Craft in Arthroscopic Rotator Cuff Repair: Where Have We Been and Where We Are Going.
Burkhart, Stephen S
2015-08-01
The rather turbulent history of arthroscopic rotator cuff repair went through stages of innovation, conflict, disruption, assimilation, and transformation that might be anticipated when a new and advanced technology (arthroscopic cuff repair) displaces an entrenched but outdated discipline (open cuff repair). The transition from open to arthroscopic rotator cuff repair has been a major paradigm shift that has greatly benefited patients. However, this technical evolution/revolution has also imposed a higher "burden of craft" on the practitioners of arthroscopic rotator cuff repair. Technological advancements in surgery demand that surgeons accept this burden of craft and master the advanced technology for the benefit of their patients. This article outlines the author's involvement in the development of arthroscopic rotator cuff repair, and it also explores the surgeon's obligation to accept the burden of craft that is imposed by this discipline.
Alterations of the Deltoid Muscle After Open Versus Arthroscopic Rotator Cuff Repair.
Cho, Nam Su; Cha, Sang Won; Rhee, Yong Girl
2015-12-01
Open repair can be more useful than arthroscopic repair for immobile and severely retracted, large to massive rotator cuff tears. However, it is not known whether the deltoid muscle is altered after open repair or to what extent the deltoid origin remains detached after surgery. To compare postoperative alterations of the deltoid muscle in open versus arthroscopic repair for severely retracted, large to massive rotator cuff tears. Case-control study; Level of evidence, 3. Enrolled in this study were 135 patients who underwent surgical repair for severely retracted, large to massive rotator cuff tears and who had routine follow-up MRIs at least 6 months after surgery. Open repairs were performed in 56 cases and arthroscopic repairs in 79 cases. The detachment and thickness of the deltoid muscle at its proximal origin were recorded in 5 zones on MRI. The alterations of the deltoid muscle and postoperative integrity of the repaired rotator cuff were evaluated. Partial detachment of the deltoid occurred in 1 patient (1.8%) in the open group and in 2 patients (2.5%) in the arthroscopic group (P = .80). All the partial detachments occurred in zones 2 and 3. Attenuation of the proximal origin of the deltoid was found in 3 patients (5.4%) in the open group and in 4 patients (5.1%) in the arthroscopic group (P = .87). Atrophy of the deltoid muscle was shown in 3 patients (5.4%) in the open group and 4 patients (5.1%) in the arthroscopic group (P = .61). The retear rate of the repaired cuff was 30.4% (17/56) in the open group and 38.0% (30/79) in the arthroscopic group (P = .74). Between open and arthroscopic repair for severely retracted, large to massive rotator cuff tears, there was no significant difference in detachment of the deltoid origin and alterations of the deltoid muscle after repair. Postoperative alterations of the deltoid occurred in arthroscopic surgery as well as in open surgery. For immobile massive rotator cuff tear, open repair is an acceptable technique
Surgical Versus Nonsurgical Management of Rotator Cuff Tears: Predictors of Treatment Allocation.
Kweon, Christopher; Gagnier, Joel J; Robbins, Christopher B; Bedi, Asheesh; Carpenter, James E; Miller, Bruce S
2015-10-01
Rotator cuff tears are a common shoulder disorder resulting in significant disability to patients and financial burden on the health care system. While both surgical and nonsurgical management are accepted treatment options, there is a paucity of data to support a treatment algorithm for care providers. Defining variables to guide treatment allocation may be important for patient education and counseling, as well as to deliver the most efficient care plan at the time of presentation. To identify independent variables at the time of initial clinical presentation that are associated with preferred allocation to surgical versus nonsurgical management for patients with known full-thickness rotator cuff tears. Case control study; Level of evidence, 3. A total of 196 consecutive adult patients with known full-thickness rotator cuff tears were enrolled into a prospective cohort study. Robust data were collected for each subject at baseline, including age, sex, body mass index (BMI), shoulder activity score, smoking status, size of cuff tear, duration of symptoms, functional comorbidity index, the American Shoulder and Elbow Surgeons (ASES) score, the Western Ontario Rotator Cuff index (WORC), and the Veterans Rand 12-Item Health Survey (VR-12). Logistic regression was performed to identify variables associated with treatment allocation, and the corresponding odds ratios were calculated. Of the 196 patients enrolled, 112 underwent surgical intervention and 84 nonoperative management. With covariates controlled for, significant baseline patient characteristics predictive of eventual allocation to surgical treatment included younger age, lower BMI, and durations of symptoms less than 1 year. Increasing age, higher BMI, and duration of symptoms longer than 1 year were predictive of nonsurgical treatment. Factors that were not associated with treatment allocation included sex, tear size, functional comorbidity score, or any of the patient-derived outcome scores at presentation
Recurrent vaginal discharge in children.
McGreal, Sharon; Wood, Paul
2013-08-01
Childhood vaginal discharge remains a frequent reason for referral from primary to secondary care. The Pediatric and Adolescent Gynecology (PAG) service at Kettering General Hospital was established in 1993 and provides a specialized service that meets the needs of children with gynaecological conditions. To investigate recurrent vaginal discharge noting symptomatology, defining pathogens, common and rarer causes, exploring management regimes, and any changes in practice over time. Retrospective review spanning 15 years identifying prepubertal children attending the outpatient PAG clinic with recurrent vaginal discharge. We reviewed the medical notes individually. 110 patients were identified; 85% were referred from primary care. The age distribution was bimodal at four and eight years. Thirty-five percent of our patients were discharged after the initial consultation. The commonest cause of discharge was vulvovaginitis (82%). Other important causes included suspected sexual abuse (5%), foreign body (3%), labial adhesions (3%), vaginal agenesis (2%). 35% of patients were admitted for vaginoscopy. Vaginal discharge is the most common gynecological symptom in prepubertal girls and can cause repeated clinical episodes. Vulvovaginitis is the most common cause and often responds to simple hygiene measures. Awareness of the less common causes of vaginal discharge is essential. Copyright © 2013 North American Society for Pediatric and Adolescent Gynecology. Published by Elsevier Inc. All rights reserved.
Arthroscopic trans-osseous rotator cuff repair
Chillemi, Claudio; Mantovani, Matteo
2017-01-01
Summary Background: Mechanical factors are at the basis of any tendon healing process, being pressure an aspect able to positively influence it. For this reason transosseous rotator cuff repair represents the gold standard procedure for patients affected by a cuff tear, maximizing the tendon footprint contact area and reducing motion at the tendon to bone interface. Methods: The Authors present an all arthroscopic suture bridge-like transosseous repair with the preparation of a single transosseous tunnel perfor med thanks to a precise dedicated instrument (Compasso®) and one implant (Elite-SPK®) with the use of only 3 suture wires. In addition this technique permits to accurately prepare the bony side of the lesion without any risk or complication, such as anchor pull-out and greater tuberosity bone osteolysis. Conclusions: However, even if this technique seems less demanding, the arthroscopic transosseous repair is still an advanced procedure, and should be performed only by well prepared arthroscopic shoulder surgeons. Level of evidence: V. PMID:28717607
Pericolini, Eva; Gabrielli, Elena; Amacker, Mario; Kasper, Lydia; Roselletti, Elena; Luciano, Eugenio; Sabbatini, Samuele; Kaeser, Matthias; Moser, Christian; Hube, Bernhard; Vecchiarelli, Anna
2015-01-01
ABSTRACT Vaginal inflammation (vaginitis) is the most common disease caused by the human-pathogenic fungus Candida albicans. Secretory aspartyl proteinases (Sap) are major virulence traits of C. albicans that have been suggested to play a role in vaginitis. To dissect the mechanisms by which Sap play this role, Sap2, a dominantly expressed member of the Sap family and a putative constituent of an anti-Candida vaccine, was used. Injection of full-length Sap2 into the mouse vagina caused local neutrophil influx and accumulation of the inflammasome-dependent interleukin-1β (IL-1β) but not of inflammasome-independent tumor necrosis factor alpha. Sap2 could be replaced by other Sap, while no inflammation was induced by the vaccine antigen, the N-terminal-truncated, enzymatically inactive tSap2. Anti-Sap2 antibodies, in particular Fab from a human combinatorial antibody library, inhibited or abolished the inflammatory response, provided the antibodies were able, like the Sap inhibitor Pepstatin A, to inhibit Sap enzyme activity. The same antibodies and Pepstatin A also inhibited neutrophil influx and cytokine production stimulated by C. albicans intravaginal injection, and a mutant strain lacking SAP1, SAP2, and SAP3 was unable to cause vaginal inflammation. Sap2 induced expression of activated caspase-1 in murine and human vaginal epithelial cells. Caspase-1 inhibition downregulated IL-1β and IL-18 production by vaginal epithelial cells, and blockade of the IL-1β receptor strongly reduced neutrophil influx. Overall, the data suggest that some Sap, particularly Sap2, are proinflammatory proteins in vivo and can mediate the inflammasome-dependent, acute inflammatory response of vaginal epithelial cells to C. albicans. These findings support the notion that vaccine-induced or passively administered anti-Sap antibodies could contribute to control vaginitis. PMID:26037125
Macías-Hernández, Salvador Israel; Pérez-Ramírez, Luis Enrique
2015-01-01
Rotator cuff tears are the leading cause of pain and functional disability of the shoulder. Conservative treatment is an essential part of their management. Despite the limited evidence, rehabilitation is the mainstay of the treatment for rotator cuff tears associated to impingement syndrome. There are current reports on the utility of strengthening with resistance, particularly by eccentric exercise. This report aims to present an overview of the efficacy of eccentric exercises in tendinopathies and current evidence of its benefit in rotator cuff tears. We describe the information available in tendinopathy and analyzed four studies published on eccentric strengthening for rotator cuff tears. There is theoretical evidence about its usefulness in this pathology, but only a controlled clinical trial has been published with data on improvement in strength but not in pain or functionality. More studies are needed with better methodological designs in order to generate evidence of their utility and recommendation. Copyright © 2015. Published by Masson Doyma México S.A.
Clinical effects of thigh cuffs during a 7-day 6° head-down bed rest
NASA Astrophysics Data System (ADS)
Pavy-Le Traon, Anne; Maillet, Alain; Vasseur Clausen, Pascale; Custaud, Marc-Antoine; Alferova, Irina; Gharib, Claude; Fortrat, Jacques-Olivier
2001-08-01
Thigh cuffs are used by Russian cosmonauts to limit the fluid shift induced by space flight. A ground simulation using the head-down bed rest (HDBR) model was performed to assess the effects of thigh cuffs on clinical tolerance and orthostatic adaptation. 8 male healthy volunteers (32.4±1.9 years) participated twice in a 7-day HDBR — one time with thigh cuffs (worm daily from 9 am to 7 pm) (TC) and one time without (WTC). Orthostatic tolerance was assessed by a 10 minute stand test and by a LBNP test (5 min at -15, -30, -45 mmHg) before (BDC-1) and at the end of the HDBR period (R+1). Plasma volume was measured before and at the end of HDBR by the Evans blue dye dilution technique. Thigh cuffs limits headache due to fluid shift, as well as the loss in plasma volume (TC: -5.85±0.95%; WTC: -9.09±0.82%, p<0.05). The mean duration of the stand test (R+1) did not differ in the two group (TC 7.1±1.3 min; WTC 7.0±1.0 min). The increase in HR and decrease in diastolic blood pressure were slightly but significantly larger without thigh cuffs. Duration of the LBNP tests did not differ with thigh cuffs. Thigh cuffs limit the symptoms due to fluid shift and the loss in plasma volume. They partly reduced the increase in HR during orthostatic stress but had no effect on duration of orthostatic stress tests.
21 CFR 884.5920 - Vaginal insufflator.
Code of Federal Regulations, 2010 CFR
2010-04-01
... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Vaginal insufflator. 884.5920 Section 884.5920 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED... § 884.5920 Vaginal insufflator. (a) Identification. A vaginal insufflator is a device used to treat...
Treatment of Partial Rotator Cuff Tear with Ultrasound-guided Platelet-rich Plasma
Sengodan, Vetrivel Chezian; Kurian, Sajith; Ramasamy, Raghupathy
2017-01-01
Background: The treatment of symptomatic partial rotator cuff tear has presented substantial challenge to orthopaedic surgeons as it can vary from conservative to surgical repair. Researches have established the influence of platelet rich plasma in healing damaged tissue. Currently very few data are available regarding the evidence of clinical and radiological outcome of partial rotator cuff tear treated with ultrasound guided platelet rich plasma injection in English literature. Materials and Methods: 20 patients with symptomatic partial rotator cuff tears were treated with ultrasound guided platelet rich plasma injection. Before and after the injection of platelet rich plasma scoring was done with visual analogue score, Constant shoulder score, and UCLA shoulder score at 8 weeks and third month. A review ultrasound was performed 8 weeks after platelet rich plasma injection to assess the rotator cuff status. Results: Our study showed statistically significant improvements in 17 patients in VAS pain score, constant shoulder score and UCLA shoulder score. No significant changes in ROM were noted when matched to the contra-lateral side (P < 0.001) at the 3 month follow-up. The study also showed good healing on radiological evaluation with ultrasonogram 8 weeks after platelet rich plasma injection. Conclusion: Ultrasound guided platelet rich plasma injection for partial rotator cuff tears is an effective procedure that leads to significant decrease in pain, improvement in shoulder functions, much cost-effective and less problematic compared to a surgical treatment. PMID:28900553
Combined electric and pressure cuff pain stimuli for assessing conditioning pain modulation (CPM).
Tsukamoto, M; Petersen, K K; Mørch, C D; Arendt-Nielsen, L
2017-12-29
Aims Traditionally, conditioning pain modulation (CPM) can be assessed by applying a test stimulus (TS) before and after application of a conditioning stimulus (CS), which is normally applied extra-segmental. Currently, no studies have attempted to apply the TS and CS to the same site using different stimuli modalities. The aim of this study was to evaluate electrical TS and cuff pressure CS applied to the same experimental site for studying CPM. Methods 20 male volunteers participated in this study, which consisted of stimulations applied by a cuff-algometer (NociTech and Aalborg University, Denmark) and current stimulator (Digitimer DS5, UK), through two Ag/AgCl electrodes (Ambu® Neuroline 700, Denmark). The cuff was wrapped around the lower leg and stimulation electrodes were placed under the cuff and to the same location on the contralateral leg. Electrical TS were applied to the non-dominant leg with or without cuff pressure CS on the dominant (CS1) or the same (non-dominant) leg (CS2, electrode under cuff). The subjects were instructed to rate the electrical evoked pain intensity on a 10-cm continuous visual analog scale (VAS, "0" represented "no pain", and "10" represented "maximal pain"). The pain detection threshold (PDT) was defined as "1" on the VAS scale. Results There was no significant deference in PDT for neither CS1 nor CS2. A median split subanalysis on CPM-responders versus CPM-nonresponders to the TS + CS1 combination. Using this grouping, there was significant increase in PDT when comparing TS to TS + CS1 or TS + CS2 (4.0 mA vs 5.6 mA; P < 0.05, 4.0 mA vs 5.1 mA; P < 0.05). Conclusions The study indicates that CPM can be evoked in a subgroup of subjects by applying the electrical test stimulus and cuff pressure conditioning stimuli to the same experimental site.
Rotator cuff tendinopathy: is there a role for polyunsaturated Fatty acids and antioxidants?
Lewis, Jeremy S; Sandford, Fiona M
2009-01-01
Despite the lack of robust evidence, there has been a steady increase in the use of dietary supplements, including Omega 3 fatty acids and antioxidants, in the management of musculoskeletal conditions. One reason for this is that unsatisfactory outcomes with conventional treatments have lead sufferers to seek alternative solutions including the use of nutritional supplements. In the United Kingdom alone, the current supplement market is estimated to be over 300 pounds million per annum. One target market for nutritional supplements is tendinopathies including conditions involving the rotator cuff. This condition is debilitating and associated with considerable morbidity. Incidence increases with advancing age. High levels of cytokines, such as the pro-inflammatory interleukin 1 beta and vascular endothelial growth factor, have been reported within the bursa of patients with rotator cuff disease. There is also evidence that high concentrations of free-radical oxidants may also be involved in tendon pathology. Therefore, the possibility exists that dietary supplements may have a beneficial effect on tendon pathology, including that of the rotator cuff. A review was conducted to synthesize the available research literature on the histopathology of rotator cuff disease and the effectiveness of polyunsaturated fatty acids (PUFAs) and antioxidants on tendinopathies. A search was conducted using the MEDLINE, CINAHL, AMED, EMBASE, Cochrane, and PEDro databases using the terms "rotator cuff" and "tear/s" and "subacromial impingement syndrome," "burase," "bursitis," "tendinopathy," "tendinitis," "tendinosis," "polyunsaturated fatty acids," "PUFA," "Omega 3," "histopathology," "etiology," and "antioxidants." English language was an inclusion criterion. There were no randomized clinical trials found relating specifically to the rotator cuff. Only one trial was found that investigated the efficacy of PUFAs and antioxidants on tendinopathies. The findings suggest that some (low
Hammann, R; Kronibus, A; Lang, N; Werner, H
1987-07-01
Vaginal washings of 22 patients with vaginitis, 11 with vaginosis, and 12 healthy subjects were investigated quantitatively and qualitatively for aerobic and anaerobic bacteria and yeasts. Gardnerella vaginalis was recovered from 9 of the vaginitis patients, 7 of the vaginosis patients, and 4 of the asymptomatic subjects. Obligate anaerobes were found in 11 of the vaginitis patients, 4 of the vaginosis patients, and none of the control subjects. Bacteroides bivius was the anaerobe most frequently isolated from symptomatic subjects. Anaerobic vibrios were recovered twice from symptomatic subjects. The counts for Gardnerella vaginalis and anaerobes when present were generally very high. The most frequent aerobes were beta-hemolytic streptococci (group B) and staphylococci.
... discharge usually is thin and dark or dull gray, but may have a greenish color. Itching is ... trichomoniasis? Signs of trichomoniasis may include a yellow-gray or green vaginal discharge. The discharge may have ...
Ohzono, Hiroki; Gotoh, Masafumi; Nakamura, Hidehiro; Honda, Hirokazu; Mitsui, Yasuhiro; Kakuma, Tatsuyuki; Okawa, Takahiro; Shiba, Naoto
2017-11-01
Fatty degeneration of the rotator cuff muscles is associated not only with postoperative retear but also with postoperative muscle weakness; therefore, fatty changes in the muscles may affect the clinical outcome even in patients with these tears who have intact tendons after arthroscopic rotator cuff repair (ARCR). To evaluate the effect of fatty infiltration on the clinical outcome in patients with intact tendons after arthroscopic repair of large/massive cuff tears. Case-control study; Level of evidence, 3. One hundred fifty-five consecutive patients with large/massive rotator cuff tears underwent ARCR. Of these, 55 patients (mean ± SD age, 64.4 ± 9.1 years) in whom intact tendons after surgery were confirmed with magnetic resonance imaging at final follow-up (mean ± SD, 2.5 ± 1.4 years) were included in this study. Depending on their University of California Los Angeles (UCLA) score at the final follow-up, they were assigned to either the unsatisfactory group (score ≤27; n = 12) or the satisfactory group (score >27; n = 43). Various clinical parameters affecting the clinical outcome were examined through univariate and multivariate analyses. The UCLA score of all patients significantly improved from 18.1 ± 4.4 points preoperatively to 29.8 ± 4.5 points postoperatively ( P < .0001). The mean preoperative UCLA scores were not significantly different between the satisfactory and unsatisfactory groups ( P = .39). Multivariate analysis showed that the preoperative Goutallier stages of the infraspinatus (odds ratio [OR], 8.87; 95% confidence interval [CI], 1.51-52.0; P = .016) and/or subscapularis (OR, 7.53; 95% CI, 1.58-35.9; P = .011) were significantly associated with outcome. Receiver operating characteristic curve analysis revealed a cutoff value of Goutallier stage 1 in both muscles, with area under the curve values of 0.79 (sensitivity 91% and specificity 51%) and 0.84 (sensitivity 100% and specificity 54%) in the infraspinatus and subscapularis
del Cotillo Fuente, M; Valls Matarín, J
2014-01-01
To quantify the hours of mechanical ventilation in patients with head of bed elevation≥30°. Determining compliance of cuff measurement every 6h. Descriptive longitudinal study. Measured: time head of bed elevation≥30°, <30° and reasons for non compliance, as well as cuff control every 6h. One hundred and seventy-two records of head of bed elevation and 584 of cuff pressure. Daily average head<30° for care or procedures: 2h (1h19'). The theoretical average number of hours that patients should remain at≥30° was 21h15' (3h) and actual 14h (5h) (P<.001). Registration of cuff was 76,7%. Cuffs between 20-30cmH2O were 75.9%. The 20% of cuff pressure were measured every 6h<20cmH2O and 33.7% when the interval was higher (P=.04). A third of the day patients are<30° without justification. Cuff pressure registration and percentage of therapeutic range are high. Control every 6h decreases the cuff with pressure<20cmH2O. Copyright © 2013 Elsevier España, S.L.U. y SEEIUC. All rights reserved.
Gurnani, Navin; van Deurzen, Derek F P; van den Bekerom, Michel P J
2017-10-01
Nontraumatic full-thickness rotator cuff tears are commonly initially treated conservatively. If conservative treatment fails, rotator cuff repair is a viable subsequent option. The objective of the present meta-analysis is to evaluate the shoulder-specific outcomes one year after arthroscopic or mini-open rotator cuff repair of nontraumatic rotator cuff tears. A literature search was conducted in PubMed and EMBASE within the period January 2000 to January 2017. All studies measuring the clinical outcome at 12 months after nontraumatic rotator cuff repair of full-thickness rotator cuff tears were listed. We included 16 randomized controlled trials that met our inclusion criteria with a total of 1.221 shoulders. At 12 months after rotator cuff repair, the mean Constant score had increased 29.5 points; the mean American Shoulder and Elbow Score score increased by 38.6 points; mean Simple Shoulder Test score was 5.6 points; mean University of California Los Angeles score improved by 13.0 points; and finally, mean Visual Analogue Scale score decreased by 4.1 points. Based on this meta-analysis, significant improvements in the shoulder-specific indices are observed 12 months after nontraumatic arthroscopic or mini-open rotator cuff repair.
Mook, William R; Greenspoon, Joshua A; Millett, Peter J
2016-01-01
Rotator cuff tears are a significant cause of shoulder morbidity. Surgical techniques for repair have evolved to optimize the biologic and mechanical variables critical to tendon healing. Double-row repairs have demonstrated superior biomechanical advantages to a single-row. The preferred technique for rotator cuff repair of the senior author was reviewed and described in a step by step fashion. The final construct is a knotless double row transosseous equivalent construct. The described technique includes the advantages of a double-row construct while also offering self reinforcement, decreased risk of suture cut through, decreased risk of medial row overtensioning and tissue strangulation, improved vascularity, the efficiency of a knotless system, and no increased risk for subacromial impingement from the burden of suture knots. Arthroscopic knotless double row rotator cuff repair is a safe and effective method to repair rotator cuff tears.
21 CFR 884.3575 - Vaginal pessary.
Code of Federal Regulations, 2010 CFR
2010-04-01
... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Vaginal pessary. 884.3575 Section 884.3575 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL... Vaginal pessary. (a) Identification. A vaginal pessary is a removable structure placed in the vagina to...
Hantoushzadeh, Sedigheh; Sheikh, Mahdi; Javadian, Pouya; Shariat, Mamak; Amini, Elaheh; Abdollahi, Alireza; Kashanian, Maryam
2014-04-01
To assess the association of vaginal pH ≥ 5 in the absence of vaginal infection with systemic inflammation and adverse pregnancy outcome. Four-hundred sixty pregnant women completed the study, upon enrollment Vaginal pH was measured for all women, maternal and umbilical sera were obtained for determining C-reactive protein (CRP) and uric acid levels. Umbilical blood was tested for gas parameters, 1 and 5 min Apgar scores, the need for neonatal resuscitation and neonatal intensive care unit (NICU) admission were recorded. Elevated vaginal pH was significantly associated with preterm birth (odds ratio (OR), 2.23; 95% confidence interval (CI), 1.04-4.76), emergency cesarean section (OR 2.57; 95% CI 1.32-5), neonatal resuscitation in the delivery room (OR 2.85; 95% CI 1.1-7.38), elevated cord base deficit (OR 8.01; 95% CI 1.61-39.81), low cord bicarbonate (OR 4.16, 95% CI 1.33-12.92) and NICU admission (OR 2.02; 95% CI 1.12-3.66). Increased vaginal pH was also significantly associated with maternal leukocytosis, hyperuricemia and elevated CRP levels in maternal and umbilical sera. Elevated vaginal pH in the absence of current vaginal infection still constitutes a risk for adverse pregnancy outcome which is mediated by systemic inflammatory response.
Jeon, Yoon Sang; Kim, Rag Gyu; Shin, Sang-Jin
2018-05-16
The purpose of this study was to identify the tear pattern that could be anatomically repaired by preserving the remaining tendon on footprint and evaluate clinical outcomes of patients who underwent remaining tendon preserving cuff repair. Of 523 patients with full-thickness rotator cuff tears who underwent arthroscopic repair, 41 (7.8%) patients had repairable rotator cuff tear while preserving the remaining tendon. Among them, 31 patients were followed-up for more than 2 years, including 26 patients with posterior L-shaped tear and 5 patients with transtendinous tear patterns. Clinical outcomes were evaluated using ASES and Constant score, SANE score for patient satisfaction, and VAS for pain. MRI was taken for tendon integrity 6 months postoperatively. Of the 31 patients, 11 (35.5%) had previous injury history before rotator cuff tear, including 7 (26.9%) of the 26 patients with posterior L-shaped tear and 4 (80%) of the 5 patients with transtendinous tear. The average size of preoperative cuff tear was 17.8 ± 6.8 mm in anterior-to-posterior direction and 15.2 ± 5.1 mm in medial-to-lateral direction. ASES and Constant score, SANE score, and VAS for pain were significantly (p < 0.001) improved after remaining tendon preserving rotator cuff repair. Rotator cuff tendons of 22(84.6%) patients with posterior L-shaped tear and 4(80%) patients with transtendinous tear patterns were healed. Patients who underwent rotator cuff repair with preservation of the remaining tendon on the footprint obtained satisfactory functional outcomes. Rotator cuff tears in patients who had posterior L-shaped tear extending between supraspinatus and infraspinatus tendons or transtendinous tear pattern with substantial remaining tendon could be repaired using remaining tendon preserving repair technique. Anatomic reduction of torn cuff tendon without undue tension could be achieved using the remaining tendon preserving repair technique.
Bowton, David L; Hite, R Duncan; Martin, R Shayn; Sherertz, Robert
2013-10-01
Aspiration of colonized oropharyngeal secretions is a major factor in the pathogenesis of ventilator-associated pneumonia (VAP). A tapered-cuff endotracheal tube (ETT) has been demonstrated to reduce aspiration around the cuff. Whether these properties are efficacious in reducing VAP is not known. This 2-period, investigator-initiated observational study was designed to assess the efficacy of a tapered-cuff ETT to reduce the VAP rate. All intubated, mechanically ventilated patients over the age of 18 were included. During the baseline period a standard, barrel-shaped-cuff ETT (Mallinckrodt Hi-Lo) was used. All ETTs throughout the hospital were then replaced with a tapered-cuff ETT (TaperGuard). The primary outcome variable was the incidence of VAP per 1,000 ventilator days. We included 2,849 subjects, encompassing 15,250 ventilator days. The mean ± SD monthly VAP rate was 3.29 ± 1.79/1,000 ventilator days in the standard-cuff group and 2.77 ± 2.00/1,000 ventilator days in the tapered-cuff group (P = .65). While adherence to the VAP prevention bundle was high throughout the study, bundle adherence was significantly higher during the standard-cuff period (96.5 ± 2.7%) than in the tapered-cuff period (90.3 ± 3.5%, P = .01). In the setting of a VAP rate very near the average of ICUs in the United States, and where there was high adherence to a VAP prevention bundle, the use of a tapered-cuff ETT was not associated with a reduction in the VAP rate.
Massive aspiration past the tracheal tube cuff caused by closed tracheal suction system.
Dave, Mital H; Frotzler, Angela; Madjdpour, Caveh; Koepfer, Nelly; Weiss, Markus
2011-01-01
Aspiration past the tracheal tube cuff has been recognized to be a risk factor for the development of ventilator-associated pneumonia (VAP). This study investigated the effect of closed tracheal suctioning on aspiration of fluid past the tracheal tube cuff in an in vitro benchtop model. High-volume low pressure tube cuffs of 7.5 mm internal diameter (ID) were placed in a 22 mm ID artificial trachea connected to a test lung. Positive pressure ventilation (PPV) with 15 cm H₂O peak inspiratory pressure and 5 cm H₂O positive end-expiratory pressure (PEEP) was used. A closed tracheal suction system (CTSS) catheter (size 14Fr) was attached to the tracheal tube and suction was performed for 5, 10, 15, or 20 seconds under 200 or 300 cm H₂O suction pressures. Amount of fluid (mL) aspirated along the tube cuff and the airway pressure changes were recorded for each suction procedure. Fluid aspiration during different suction conditions was compared using Kruskal-Wallis and Mann-Whitney test (Bonferroni correction [α = .01]). During 10, 15, and 20 seconds suction, airway pressure consistently dropped down to -8 to -13 cm H₂O (P < .001) from the preset level. Fluid aspiration was never observed under PPV + PEEP but occurred always during suctioning. Aspiration along the tube cuff was higher with -300 cm H₂O than with -200 cm H₂O suction pressure (P < .001) and was much more during 15 and 20 seconds suction time as compared to 5 seconds (P < .001). Massive aspiration of fluid occurs along the tracheal tube cuff during suction with the closed tracheal suction system. © SAGE Publications 2011.
Dilisio, Matthew F.; Miller, Lindsay R.; Higgins, Laurence D.
2014-01-01
Arthroscopic transtendinous techniques for the arthroscopic repair of partial-thickness, articular-surface rotator cuff tears offer the advantage of minimizing the disruption of the patient's remaining rotator cuff tendon fibers. In addition, double-row fixation of full-thickness rotator cuff tears has shown biomechanical advantages. We present a novel method combining these 2 techniques for transtendon, double-row, transosseous-equivalent arthroscopic repair of partial-thickness, articular-surface rotator cuff tears. Direct visualization of the reduction of the retracted articular tendon layer to its insertion on the greater tuberosity is the key to the procedure. Linking the medial-row anchors and using a double-row construct provide a stable repair that allows early shoulder motion to minimize the risk of postoperative stiffness. PMID:25473606
Dilisio, Matthew F; Miller, Lindsay R; Higgins, Laurence D
2014-10-01
Arthroscopic transtendinous techniques for the arthroscopic repair of partial-thickness, articular-surface rotator cuff tears offer the advantage of minimizing the disruption of the patient's remaining rotator cuff tendon fibers. In addition, double-row fixation of full-thickness rotator cuff tears has shown biomechanical advantages. We present a novel method combining these 2 techniques for transtendon, double-row, transosseous-equivalent arthroscopic repair of partial-thickness, articular-surface rotator cuff tears. Direct visualization of the reduction of the retracted articular tendon layer to its insertion on the greater tuberosity is the key to the procedure. Linking the medial-row anchors and using a double-row construct provide a stable repair that allows early shoulder motion to minimize the risk of postoperative stiffness.
Vaginal eroticism: a replication study.
Alzate, H
1985-12-01
Vaginal eroticism was investigated in a group of 27 coitally experienced volunteers by means of systematic digital stimulation of both vaginal walls. Erogenous zones were found in all subjects, mainly located on the upper anterior wall and the lower posterior one. An orgasmic response was elicited by stimulation of these zones in 89% of the subjects. This study supports previous findings regarding vaginal eroticism. It does not support the existence of the discrete anatomical structure called the Grafenberg spot. It supports the contention that there are two distinct types of female orgasm, vaginally evoked and clitorally evoked. It also supports the finding that some women expel a fluid through the urethra at the time of orgasm. In this particular case the fluid was chemically indistinguishable from urine.
Grewal, Harjeet; Varshney, Kavita; Thomas, Lee C; Kok, Jen; Shetty, Amith
2013-06-01
Blood pressure (BP) cuffs are potential vectors for transmission of multi-resistant organisms (MROs). The present study aims to determine MRO colonisation rates in BP cuffs from areas of high patient flow as an assessment of the quality of disinfection and infection control practices. BP cuffs in the ED, high dependency unit (HDU) and operating theatres (OT) were prospectively examined after routine disinfection procedures. Swabs collected from the inner and outer surfaces of BP cuffs during inter-patient intervals were plated onto replicate organism detection and counting, methicillin-resistant Staphylococcus aureus (MRSA) and vancomycin-resistant Enterococcus (VRE) chromogenic agar plates to detect rates of bacterial, MRSA and VRE colonisation, respectively. High bacterial colonisation rates were detected in BP cuffs from all three areas. BP cuffs from OT were significantly less colonised compared with cuffs from HDU and ED; 76% versus 96% and 100% (P < 0.0001) for inner surfaces and 86% versus 98% and 100% (P < 0.0001) for outer surfaces, respectively. Equivalent or higher bacterial growth was observed on the inner surface compared with outer surface in 54%, 84% and 86% of BP cuffs from OT, HDU and ED, respectively. MRSA was detected in 3 of 150 (2%) swabs collected, but no VRE was detected. Although MRSA and VRE were infrequently isolated, current disinfection and infection control protocols need to be improved given the greater recovery of organisms from the inner compared with outer surfaces of BP cuffs. © 2013 Australasian College for Emergency Medicine and Australasian Society for Emergency Medicine.
Lawani, Lucky O; Anozie, Okechukwu B; Ezeonu, Paul O; Iyoke, Chukwuemeka A
2014-06-01
To evaluate the incidence of, indications for, and outcome of operative vaginal deliveries compared with spontaneous vaginal deliveries in southeast Nigeria. A retrospective cohort study was conducted involving cases of operative vaginal delivery performed at Ebonyi State University Teaching Hospital over a 10-year period. Data on the procedures were abstracted from the operation notes of the medical records of parturients. An incidence of 4.7% (n = 461) was recorded. The most common indications for vacuum and forceps delivery were prolonged second stage of labor (44.9%) and poor maternal effort (27.8%). The only indication for destructive operation was intrauterine fetal death (3.7%). The risk ratio (RR) for hemorrhage/vulvar hematoma was 1.14 (95% confidence interval [CI], 0.53-2.48) for vacuum-assisted delivery and 5.49 (95% CI, 0.82-36.64) for forceps delivery. The RR for genital laceration was 1.21 (95% CI, 0.44-3.30) for vacuum-assisted delivery and 9.41 (95% CI, 1.33-66.65) for forceps delivery. The risk of fetal scalp bruises and caput succedaneum was higher for operative vaginal delivery than for spontaneous vaginal delivery, with no significant difference in maternal morbidity. The perinatal mortality rate was 0.9 per 1000 live births. Operative vaginal delivery by experienced healthcare providers is associated with good obstetric outcomes with minimal risk. Copyright © 2014 International Federation of Gynecology and Obstetrics. Published by Elsevier Ireland Ltd. All rights reserved.
Pepke, W; Brunner, M; Abel, R; Almansour, H; Gerner, H J; Hug, A; Zeifang, F; Kentar, Y; Bruckner, T; Akbar, M
2018-02-27
Shoulder pain and rotator cuff tears are highly prevalent among wheelchair dependent individuals with paraplegia. The purpose of this study was to identify potential risk factors associated with the development of rotator cuff tears in this population. A total of 217 wheelchair dependent individuals with paraplegia were included in this cross-sectional study (level of evidence III). The mean age of this population was 47.9 years and the mean duration of wheelchair dependence was 24.1 years. Each individual was asked to complete a questionnaire designed to identify risk factors for rotator cuff tears and underwent a standardized clinical examination with the documentation of the Constant-Murley shoulder outcome score and magnetic resonance imaging (MRI) of both shoulder joints. MRI analysis revealed at least one rotator cuff tear in 93 patients (43%). Multiple logistic regression analysis identified the following factors to be associated with the presence of rotator cuff tear: patient age, duration of spinal cord injury/wheelchair dependence, gender, and wheelchair athletic activity. Neither BMI nor the level of spinal cord injury was found to pose a risk factor in the population studied. With respect to patient age, the risk of developing a rotator cuff tear increased by 11% per annum. In terms of duration of spinal cord injury, the analysis revealed a 6% increased risk per year of wheelchair dependence (OR = 1.06). Females had a 2.6-fold higher risk of developing rotator cuff tears than males and wheelchair sport activity increased the risk 2.3-fold. There is a high prevalence of rotator cuff tears in wheel-chair dependent persons with paraplegia. Risk factors such as age, gender, duration of paraplegia, and wheel chair sport activity seem to play an important role in the development of rotator cuff tears.
Kholinne, Erica; Lee, Hyun Joo; Kim, Sung Jung; Park, So Hyun; Jeon, In-Ho
2018-01-01
The aim of this study was to compare the microarchitecture of the greater tuberosity with or without rotator cuff tear and to obtain optimum location for anchor screw insertion for rotator cuff repair. Twenty-five humeral heads were harvested from 13 male cadavers of mean age 58.4 years, including 6 humeri with rotator cuff tear and 19 intact humeri. Six regions of interest (proximal, intermediate, and distal zones of the superficial and deep regions) were divided into the anterior (G1), middle (G2), and posterior (G3) areas of the greater tuberosity. Trabecular bone volume and cortical thickness were evaluated. Total trabecular bone volume was greater in subjects <50 years old than in subjects >50 years old but did not differ significantly in subjects with and without rotator cuff tear. Cortical thickness in both intact and torn rotator cuff groups was significantly greater in the proximal and intermediate zones than in the distal zone. Cortical thickness was related to anatomic location rather than age or cuff tear. The optimal location for anchor screw insertion during rotator cuff repair is either the proximal or intermediate region of the greater tuberosity. Age has more influence in terms of trabecular bone volume loss than rotator cuff integrity. Copyright © 2017. Production and hosting by Elsevier B.V.
Cuff, Derek J; Pupello, Derek R; Santoni, Brandon G
2016-11-01
A subset of patients with massive irreparable rotator cuff tears present with retained overhead elevation and pain as their primary complaint. Our aim was to evaluate the outcomes of partial arthroscopic rotator cuff repair with biceps tenotomy and to report the failure rate of this procedure for patients with >5 years of follow-up. Thirty-four patients underwent partial rotator cuff repair and biceps tenotomy for treatment of a massive rotator cuff tear. Patients had preoperative active forward elevation >120° and no radiographic evidence of glenohumeral arthritis. Patients were followed up clinically and radiographically, and 28 patients had a minimum of 5 years of follow-up. Failure was defined as an American Shoulder and Elbow Surgeons score of <70, loss of active elevation >90°, or revision to reverse shoulder arthroplasty during the study period. Patients demonstrated improvements in average preoperative to postoperative American Shoulder and Elbow Surgeons scores (46.6 to 79.3 [P < .001]) and Simple Shoulder Test scores (5.7 to 9.1 [P < .001]) along with decrease in visual analog scale for pain scores (6.9 to 1.9 [P < .001]). No significant change in forward elevation (168° to 154° [P = .07]), external rotation (38° to 39° [P = 1.0]), or internal rotation (84% to 80% [P = 1.0]) was identified; 36% of patients had progression of the Hamada stage. The failure rate was 29%; 75% of patients were satisfied with their index procedure. Partial rotator cuff repair and biceps tenotomy for patients with massive irreparable rotator cuff tears with retained overhead elevation and pain as the primary complaint produced reasonable outcomes at midterm follow-up of at least 5 years. Copyright © 2016 Journal of Shoulder and Elbow Surgery Board of Trustees. Published by Elsevier Inc. All rights reserved.
A rare case of prosthetic endocarditis and dehiscence in a mechanical valved conduit
Kannan, Arun; Smith, Cristy; Subramanian, Sreekumar; Janardhanan, Rajesh
2014-01-01
A middle-aged adult patient with a history of aortic root replacement with a mechanical valved conduit and remote chest trauma was referred to our institution with prosthetic endocarditis. Transoesophageal echocardiogram at our institution confirmed a near-complete dehiscence of the prosthetic aortic valve from the conduit, with significant perivalvular flow forming a pseudoaneurysm. The patient underwent a high-risk re-operation, involving redo aortic root replacement with a homograft after extensive debridement of the infected tissue. The patient was discharged to an outside facility after an uncomplicated hospital course, and remains stable. PMID:24510692
A rare case of prosthetic endocarditis and dehiscence in a mechanical valved conduit.
Kannan, Arun; Smith, Cristy; Subramanian, Sreekumar; Janardhanan, Rajesh
2014-02-07
A middle-aged adult patient with a history of aortic root replacement with a mechanical valved conduit and remote chest trauma was referred to our institution with prosthetic endocarditis. Transoesophageal echocardiogram at our institution confirmed a near-complete dehiscence of the prosthetic aortic valve from the conduit, with significant perivalvular flow forming a pseudoaneurysm. The patient underwent a high-risk re-operation, involving redo aortic root replacement with a homograft after extensive debridement of the infected tissue. The patient was discharged to an outside facility after an uncomplicated hospital course, and remains stable.
Shamsudin, Aminudin; Lam, Patrick H; Peters, Karin; Rubenis, Imants; Hackett, Lisa; Murrell, George A C
2015-03-01
Symptomatic rotator cuff tears are often treated surgically. However, there is a paucity of information regarding the outcomes of revision arthroscopic rotator cuff repairs. To evaluate the outcome of revision arthroscopic rotator cuff surgery when compared with primary arthroscopic rotator cuff surgery in a large cohort of patients. Cohort study; Level of evidence, 3. A consecutive series of 50 revision arthroscopic rotator cuff repairs performed by a single surgeon, with minimum 2-year follow-up, were retrospectively reviewed using prospectively collected data. As a comparison, 3 primary arthroscopic rotator cuff repair cases (primary group; n = 310) were chosen immediately before each revision case, and 3 were chosen after. Standardized patient-ranked outcomes, examiner-determined assessments, and ultrasound-determined rotator cuff integrity were assessed preoperatively at 6 months and at a minimum of 2 years after surgery. The revision group was older (mean age, 63 years; range, 43-80 years) compared with the primary group (mean age, 60 years; range, 18-88 years) (P < .05) and had larger tear size (mean ± SEM) (4.1 ± 0.5 cm(2)) compared with the primary group (3.0 ± 0.2 cm(2)) (P < .05). Two years after surgery, the primary group reported less pain at rest (P < .02), during sleep (P < .05), and with overhead activity (P < .01) compared with the revision group. The primary group had better passive forward flexion (+13°; P < .05), abduction (+18°; P < .01), internal rotation (+2 vertebral levels; P < .001) and also significantly greater supraspinatus strength (+15 N; P < .001), lift-off strength (+9.3 N; P < .05), and adduction strength (+20 N; P < .01) compared with the revision group at 2 years. When compared with the primary group, the revision group was more satisfied with the overall shoulder function before surgery but was less satisfied with their shoulder function than the primary group at 2 years (P < .005). The retear rate for primary rotator cuff
Pang, Chun-Chiu; Scharaschkin, Tanya; Su, Yvonne C. F.; Saunders, Richard M. K.
2013-01-01
Unlike most genera in the early-divergent angiosperm family Annonaceae, Pseuduvaria exhibits a diversity of floral sex expression. Most species are structurally andromonoecious (or possibly androdioecious), although the hermaphroditic flowers have been inferred to be functionally pistillate, with sterile staminodes. Pseuduvaria presents an ideal model for investigating the evolution of floral sex in early-divergent angiosperms, although detailed empirical studies are currently lacking. The phenology and pollination ecology of the Australian endemic species Pseuduvaria mulgraveana are studied in detail, including evaluations of floral scent chemistry, pollen viability, and floral visitors. Results showed that the flowers are pollinated by small diurnal nitidulid beetles and are protogynous. Pollen from both hermaphroditic and staminate flowers are shown to be equally viable. The structurally hermaphroditic flowers are nevertheless functionally pistillate as anther dehiscence is delayed until after petal abscission and hence after the departure of pollinators. This mechanism to achieve functional unisexuality of flowers has not previously been reported in angiosperms. It is known that protogyny is widespread amongst early-divergent angiosperms, including the Annonaceae, and is effective in preventing autogamy. Delayed anther dehiscence represents a further elaboration of this, and is effective in preventing geitonogamy since very few sexually mature flowers occur simultaneously in an individual. We highlight the necessity for field-based empirical interpretations of functional floral sex expression prior to evaluations of evolutionary processes. PMID:23555844
Hollman, Freek; Wolterbeek, Nienke; Flikweert, Petra E; Yang, Kiem G Auw
2018-06-01
Fatty infiltration is an important prognostic factor for cuff healing after rotator cuff repair. Treatment options for stage 2-3 Goutallier rotator cuff tears vary widely and there is lack of decent comparative studies. The objective of this study was 1) to give an overview of the treatment options of stage 2-3 Goutallier rotator cuff tears and their clinical outcome and 2) to give a recommendation of the optimal treatment within this specific subgroup. We searched the databases of Medline, Embase, Cochrane library, NHS Centre for Reviews and Dissemination, PEDro from inception to December 12th, 2016. Two authors, F.H. and N.W., selected the studies after consensus. Data was extracted by one author (F.H.) and checked for completeness by a second author (N.W.). Our primary outcome was physical function, measured by shoulder-specific patient reported outcomes. Secondary outcomes were cuff integrity after rotator cuff repair, shoulder pain, general health, quality of life, activity level and adverse events. For the first research question 28 prospective as well as retrospective studies were included. For the clinical outcome of these treatments three randomized controlled trials were included. Despite the high reported retear rate, rotator cuff repair has comparable results (clinical improvement) as partial repair and isolated bicepstenotomy or tenodesis. These findings suggest that the additional effect of rotator cuff repair compared to the less extensive treatment options like isolated bicepstenotomy or tenodesis should be studied, as these might form a good alternative treatment based on this systematic review. Level IV; systematic review.
Magnetic resonance imaging assessment of the rotator cuff: is it really accurate?
Wnorowski, D C; Levinsohn, E M; Chamberlain, B C; McAndrew, D L
1997-12-01
Magnetic resonance imaging (MRI) is used increasingly for evaluating the rotator cuff. This study of 39 shoulders (38 patients) compared the accuracy of MRI interpretation of rotator cuff integrity by a group of community hospital radiologists (clinical community scenario, CCS) with that of a musculoskeletal radiologist (experienced specialist scenario, ESS), relative to arthroscopy. For the CCS subgroup, the sensitivity, specificity, positive predictive value (PV), negative PV, and accuracy for partial tears were: 0%, 68%, 0%, 82%, and 59%, respectively; for complete tears: 56%, 73%, 36%, 86%, and 69%, respectively; and for all tears combined: 85%, 52%, 50%, 87%, and 64%, respectively. For the ESS subgroup, the respective values for partial tears were: 20%, 88%, 20%, 88%, and 79%, respectively; for complete tears: 78%, 83%, 58%, 92%, and 82%, respectively; and for all tears: 71%, 71%, 59%, 81%, and 71%, respectively. We concluded that MRI assessment of the rotator cuff was not accurate relative to arthroscopy. MRI was most helpful if the result was negative, and MRI diagnosis of partial tear was of little value. Considering the high cost of shoulder MRI, this study has significant implications for the evaluation of patients with possible rotator cuff pathology.
Cadogan, Angela; McNair, Peter; Laslett, Mark; Hing, Wayne; Taylor, Stephen
2013-01-01
Objectives: Rotator cuff tears are a common and disabling complaint. The early diagnosis of medium and large size rotator cuff tears can enhance the prognosis of the patient. The aim of this study was to identify clinical features with the strongest ability to accurately predict the presence of a medium, large or multitendon (MLM) rotator cuff tear in a primary care cohort. Methods: Participants were consecutively recruited from primary health care practices (n = 203). All participants underwent a standardized history and physical examination, followed by a standardized X-ray series and diagnostic ultrasound scan. Clinical features associated with the presence of a MLM rotator cuff tear were identified (P<0.200), a logistic multiple regression model was derived for identifying a MLM rotator cuff tear and thereafter diagnostic accuracy was calculated. Results: A MLM rotator cuff tear was identified in 24 participants (11.8%). Constant pain and a painful arc in abduction were the strongest predictors of a MLM tear (adjusted odds ratio 3.04 and 13.97 respectively). Combinations of ten history and physical examination variables demonstrated highest levels of sensitivity when five or fewer were positive [100%, 95% confidence interval (CI): 0.86–1.00; negative likelihood ratio: 0.00, 95% CI: 0.00–0.28], and highest specificity when eight or more were positive (0.91, 95% CI: 0.86–0.95; positive likelihood ratio 4.66, 95% CI: 2.34–8.74). Discussion: Combinations of patient history and physical examination findings were able to accurately detect the presence of a MLM rotator cuff tear. These findings may aid the primary care clinician in more efficient and accurate identification of rotator cuff tears that may require further investigation or orthopedic consultation. PMID:24421626
Mook, William R.; Greenspoon, Joshua A.; Millett, Peter J.
2016-01-01
Background: Rotator cuff tears are a significant cause of shoulder morbidity. Surgical techniques for repair have evolved to optimize the biologic and mechanical variables critical to tendon healing. Double-row repairs have demonstrated superior biomechanical advantages to a single-row. Methods: The preferred technique for rotator cuff repair of the senior author was reviewed and described in a step by step fashion. The final construct is a knotless double row transosseous equivalent construct. Results: The described technique includes the advantages of a double-row construct while also offering self reinforcement, decreased risk of suture cut through, decreased risk of medial row overtensioning and tissue strangulation, improved vascularity, the efficiency of a knotless system, and no increased risk for subacromial impingement from the burden of suture knots. Conclusion: Arthroscopic knotless double row rotator cuff repair is a safe and effective method to repair rotator cuff tears. PMID:27733881
Desquamative inflammatory vaginitis. A review.
Oates, J K; Rowen, D
1990-01-01
Desquamative inflammatory vaginitis is an uncommon cause of an intractable vaginitis often accompanied by serious dyspareunia, which can occur at any stage of reproductive life and after the menopause. The cytological changes are identical with those seen in atrophic vaginitis yet the disorder often occurs in the presence of apparently normal ovarian function. Vaginal synechiae and stenosis develop in an appreciable number of patients. Treatment is unsatisfactory though there is some response to either local or systemic steroid therapy. The literature is reviewed and the association of some cases with lichen planus of the mouth and genitals discussed. Its causation and natural history remain largely unknown and there is as yet, insufficient evidence to regard it as a single entity. It is likely that the incidence of the disorder is underestimated. PMID:2202657
Human vaginal pH and microbiota: an update.
Godha, Keshav; Tucker, Kelly M; Biehl, Colton; Archer, David F; Mirkin, Sebastian
2018-06-01
A woman's vaginal pH has many implications on her health and it can be a useful tool in disease diagnosis and prevention. For that reason, the further examination of the relationship between the human vaginal pH and microbiota is imperative. In the past several decades, much has been learned about the physiological mechanisms modulating the vaginal pH, and exogenous/genetic factors that may influence it. A unified, coherent understanding of these concepts is presented to comprehend their interrelationships and their cumulative effect on a woman's health. In this review, we explore research on vaginal pH and microbiota throughout a woman's life, vaginal intermediate cell anaerobic metabolism and net proton secretion by the vaginal epithelial, and the way these factors interact to acidify the vaginal pH. This review provides foundational information about what a microbiota is and its relationship with human physiology and vaginal pH. We then evaluate the influence of physiological mechanisms, demographic factors, and propose ideas for the mechanisms behind their action on the vaginal pH.
Shinagawa, Kiyotsugu; Hatta, Taku; Yamamoto, Nobuyuki; Kawakami, Jun; Shiota, Yuki; Mineta, Mitsuyoshi; Itoi, Eiji
2018-05-03
Focus has recently been on the critical shoulder angle (CSA) as a factor related to rotator cuff tear and osteoarthritis (OA) in the European population. However, whether this relationship is observed in the Asian population is unclear. The correlation between the CSAs measured on anteroposterior radiographs and the presence or absence of rotator cuff tears or OA changes was assessed in 295 patients. Rotator cuff tears were diagnosed with magnetic resonance imaging or ultrasonography. OA findings were classified using the Samilson-Prieto classification. The CSAs among the patients with rotator cuff tears, OA changes, and those without pathologies were compared. Multivariable analyses were used to clarify the potential risks for these pathologies. The mean CSA with rotator cuff tear (33.9° ± 4.1°) was significantly greater than that without a rotator cuff tear (32.3° ± 4.5°; P = .002). Multivariable analysis also showed that a greater CSA had a significantly increased risk of rotator cuff tears, with the odds ratio of 1.08 per degree. OA findings showed no significant correlation to the CSAs. Our study demonstrates that the CSA is greater in those with a rotator cuff tear than in those without a tear or OA changes, which may be an independent risk factor for the incidence of rotator cuff tears in the Japanese population. Copyright © 2018 Journal of Shoulder and Elbow Surgery Board of Trustees. Published by Elsevier Inc. All rights reserved.
van de Wijgert, Janneke H H M; Morrison, Charles S; Cornelisse, Peter G A; Munjoma, Marshall; Moncada, Jeanne; Awio, Peter; Wang, Jing; Van der Pol, Barbara; Chipato, Tsungai; Salata, Robert A; Padian, Nancy S
2008-06-01
To evaluate interrelationships between bacterial vaginosis (BV), vaginal yeast, vaginal practices (cleansing and drying/tightening), mucosal inflammation, and HIV acquisition. A multicenter, prospective, observational cohort study was conducted, enrolling 4531 HIV-negative women aged 18 to 35 years attending family planning clinics in Zimbabwe and Uganda. Participants were tested for HIV and reproductive tract infections and were interviewed about vaginal practices every 3 months for 15 to 24 months. BV was measured by Gram stain Nugent scoring, vaginal yeast by wet mount, and mucosal inflammation by white blood cells on Gram stain. HIV incidence was 4.12 and 1.53 per 100 woman-years of follow-up in Zimbabwe and Uganda, respectively (a total of 213 incident infections). Women with BV or vaginal yeast were more likely to acquire HIV, especially if the condition was present at the same visit as the new HIV infection and the visit preceding it (hazard ratio [HR] = 2.50, 95% confidence interval [CI]: 1.68 to 3.72 and HR = 2.97, 95% CI: 1.67 to 5.28 for BV and yeast, respectively). These relationships did not seem to be mediated by mucosal inflammation. Vaginal drying/tightening was associated with HIV acquisition in univariate (HR = 1.49, 95% CI: 1.03 to 2.15) but not multivariate models. Vaginal cleansing was not associated with HIV acquisition. BV and yeast may contribute more to the HIV epidemic than previously thought.
Experimental rotator cuff repair. A preliminary study.
Gerber, C; Schneeberger, A G; Perren, S M; Nyffeler, R W
1999-09-01
The repair of chronic, massive rotator cuff tears is associated with a high rate of failure. Prospective studies comparing different repair techniques are difficult to design and carry out because of the many factors that influence structural and clinical outcomes. The objective of this study was to develop a suitable animal model for evaluation of the efficacy of different repair techniques for massive rotator cuff tears and to use this model to compare a new repair technique, tested in vitro, with the conventional technique. We compared two techniques of rotator cuff repair in vivo using the left shoulders of forty-seven sheep. With the conventional technique, simple stitches were used and both suture ends were passed transosseously and tied over the greater tuberosity of the humerus. With the other technique, the modified Mason-Allen stitch was used and both suture ends were passed transosseously and tied over a cortical-bone-augmentation device. This device consisted of a poly(L/D-lactide) plate that was fifteen millimeters long, ten millimeters wide, and two millimeters thick. Number-3 braided polyester suture material was used in all of the experiments. In pilot studies (without prevention of full weight-bearing), most repairs failed regardless of the technique that was used. The simple stitch always failed by the suture pulling through the tendon or the bone; the suture material did not break or tear. The modified Mason-Allen stitch failed in only two of seventeen shoulders. In ten shoulders, the suture material failed even though the stitches were intact. Thus, we concluded that the modified Mason-Allen stitch is a more secure method of achieving suture purchase in the tendon. In eight of sixteen shoulders, the nonaugmented double transosseous bone-fixation technique failed by the suture pulling through the bone. The cortical-bone-augmentation technique never failed. In definite studies, prevention of full weight-bearing was achieved by fixation of a ten
Shin, Sang-Jin; Chung, Jaeyoon; Lee, Juyeob; Ko, Young-Won
2016-04-01
The recovery of muscle strength after arthroscopic rotator cuff repair based on the preoperative tear size has not yet been well described. The purpose of this study was to evaluate the recovery period of muscle strength by a serial assessment of isometric strength after arthroscopic rotator cuff repair based on the preoperative tear size. The hypothesis was that muscle strength in patients with small and medium tears would recover faster than that in those with large-to-massive tears. Cohort study; Level of evidence, 3. A total of 164 patients who underwent arthroscopic rotator cuff repair were included. Isometric strength in forward flexion (FF), internal rotation (IR), and external rotation (ER) was evaluated preoperatively and at 6, 12, 18, and 24 months after surgery. Preoperative magnetic resonance imaging scans were assessed to evaluate the quality of the rotator cuff muscle, including fatty infiltration, occupation ratio, and tangent sign. Patient satisfaction as well as visual analog scale (VAS) for pain, American Shoulder and Elbow Surgeons (ASES), and Constant scores were assessed at every follow-up. Muscle strength demonstrated the slowest recovery in pain relief and the restoration of shoulder function. To reach the strength of the uninjured contralateral shoulder in all 3 planes of motion, recovery took 6 months in patients with small tears and 18 months in patients with medium tears. Patients with large-to-massive tears showed continuous improvement in strength up to 18 months; however, they did not reach the strength of the contralateral shoulder at final follow-up. At final follow-up, mean strength in FF, IR, and ER was 113.0%, 118.0%, and 112.6% of the contralateral shoulder in patients with small tears, respectively; 105.0%, 112.1%, and 102.6% in patients with medium tears, respectively; and 87.6%, 89.5%, and 85.2% in patients with large-to-massive tears, respectively. Muscle strength in any direction did not significantly correlate with
Hradilová, Iveta; Trněný, Oldřich; Válková, Markéta; Cechová, Monika; Janská, Anna; Prokešová, Lenka; Aamir, Khan; Krezdorn, Nicolas; Rotter, Björn; Winter, Peter; Varshney, Rajeev K.; Soukup, Aleš; Bednář, Petr; Hanáček, Pavel; Smýkal, Petr
2017-01-01
The origin of the agriculture was one of the turning points in human history, and a central part of this was the evolution of new plant forms, domesticated crops. Seed dispersal and germination are two key traits which have been selected to facilitate cultivation and harvesting of crops. The objective of this study was to analyze anatomical structure of seed coat and pod, identify metabolic compounds associated with water-impermeable seed coat and differentially expressed genes involved in pea seed dormancy and pod dehiscence. Comparative anatomical, metabolomics, and transcriptomic analyses were carried out on wild dormant, dehiscent Pisum elatius (JI64, VIR320) and cultivated, indehiscent Pisum sativum non-dormant (JI92, Cameor) and recombinant inbred lines (RILs). Considerable differences were found in texture of testa surface, length of macrosclereids, and seed coat thickness. Histochemical and biochemical analyses indicated genotype related variation in composition and heterogeneity of seed coat cell walls within macrosclereids. Liquid chromatography–electrospray ionization/mass spectrometry and Laser desorption/ionization–mass spectrometry of separated seed coats revealed significantly higher contents of proanthocyanidins (dimer and trimer of gallocatechin), quercetin, and myricetin rhamnosides and hydroxylated fatty acids in dormant compared to non-dormant genotypes. Bulk Segregant Analysis coupled to high throughput RNA sequencing resulted in identification of 770 and 148 differentially expressed genes between dormant and non-dormant seeds or dehiscent and indehiscent pods, respectively. The expression of 14 selected dormancy-related genes was studied by qRT-PCR. Of these, expression pattern of four genes: porin (MACE-S082), peroxisomal membrane PEX14-like protein (MACE-S108), 4-coumarate CoA ligase (MACE-S131), and UDP-glucosyl transferase (MACE-S139) was in agreement in all four genotypes with Massive analysis of cDNA Ends (MACE) data. In case of pod
General Information about Vaginal Cancer
... Research Vaginal Cancer Treatment (PDQ®)–Patient Version General Information About Vaginal Cancer Go to Health Professional Version ... the PDQ Adult Treatment Editorial Board . Clinical Trial Information A clinical trial is a study to answer ...
[Clinical characteristics of aerobic vaginitis and its mixed infections].
Fan, Ai-Ping; Xue, Feng-Xia
2010-12-01
To investigate clinical characteristics of aerobic vaginitis (AV) and its mixed infections for diagnosis efficiently. From April 2008 to December 2008, 516 patients with vaginitis treated in Tianjin Medical University General Hospital were enrolled in this study. AV, bacterial vaginosis (BV), vulvovaginal candidiasis (VVC), trichomonal vaginitis (TV), and cytolytic vaginosis (CV) were diagnosed based on symptoms, sign and vaginal discharge examination. Among 516 cases, AV cases were found in 14.7% (76/516), and AV was common vaginal infection. AV mixed infections was diagnosed in 58% (44/76), including mixed with BV (45%, 20/44), mixed with VVC (30%, 13/44), and mixed with TV (25%, 11/44). Those common symptom of AV were yellow vaginal discharge (63%, 20/32), more vaginal discharge (44%, 14/32). Vaginal pH value was usually more than 4.5 (84%, 27/32). Vaginal cleanliness mainly was grade III - IV (88%, 28/32). Six cases with enterococcus faecium and 4 cases with streptococci were frequently isolated. The symptom and sign of mixed AV infection was atypical. Aerobic vaginitis is a common lower vaginal infection and easily mixed with other pathogens, especially with BV, VVC or TV. When patients were diagnosed with AV or other vaginal infection, it should be mentioned whether those patients have mixed vaginal infection or AV.
Partial repair in irreparable rotator cuff tear: our experience in long-term follow-up.
Di Benedetto, E D; Di Benedetto, Paolo; Fiocchi, Andrea; Beltrame, Alessandro; Causero, Araldo
2017-10-18
Massive rotator cuff tears are a common source of shoulder pain and dysfunction, especially in middle age patient; these lesions represent about 20% of all rotator cuff tears and 80% of recurrent tears. Some lesions are not repairable or should not be repaired: in this case, a rotator cuff partial repair should be recommended. The aim of the study is to evaluate the outcome of rotator cuff partial repair in irreparable rotator cuff massive tear at medium and long-term follow-up. We have evaluated 74 consecutive patients treated with functional repair of rotator cuff by the same surgeon between 2006 and 2014. We divided patients into 2 groups, obtaining 2 average follow-up: at about 6,5 (group A) and 3 years (group B). In December 2015, we evaluated in every patient ROM and Constant Score. We analyzed difference between pre-operatory data and the 2 groups. Results: We found statistical significant difference in ROM and in Constant Score between pre-operatory data and group A and group B. Between group A and group B there is relevant difference in Constant Score but not in ROM. Partial repair can give good results in a medium follow-up, in terms of pain relief and improvement of ROM, as well as in quality of life. Difference in ROM and Constant Score between group A and group B may indicate the begin of partial repair failure; according to our data, 6-7 years may be the time limit for this surgery technique.
Evaluation and nonsurgical management of rotator cuff calcific tendinopathy.
Greis, Ari C; Derrington, Stephen M; McAuliffe, Matthew
2015-04-01
Rotator cuff calcific tendinopathy is a common finding that accounts for about 7% of patients with shoulder pain. There are numerous theories on the pathogenesis of rotator cuff calcific tendinopathy. The diagnosis is confirmed with radiography, MRI or ultrasound. There are numerous conservative treatment options available and most patients can be managed successfully without surgical intervention. Nonsteroidal anti-inflammatory drugs and multiple modalities are often used to manage pain and inflammation; physical therapy can help improve scapular mechanics and decrease dynamic impingement; ultrasound-guided needle aspiration and lavage techniques can provide long-term improvement in pain and function in these patients. Copyright © 2015 Elsevier Inc. All rights reserved.
Namdari, Surena; Baldwin, Keith; Ahn, Albert; Huffman, G Russell; Sennett, Brian J
2011-01-01
Little is known about pitching performance or lack of it among Major League Baseball (MLB) pitchers who undergo operative treatment of rotator cuff tears. To assess pitching performance outcomes in MLB players who needed operative treatment of rotator cuff tears and to compare performance in these athletes with that in a control group of MLB players. Case-control study. Publicly available player profiles, press releases, and team injury reports. Thirty-three MLB pitchers with documented surgery to treat rotator cuff tears and 117 control pitchers who did not have documented rotator cuff tears were identified. Major League Baseball pitching attrition and performance variables. Players who underwent rotator cuff surgery were no more likely not to play than control players. Performance variables of players who underwent surgery improved after surgery but never returned to baseline preoperative status. Players who needed rotator cuff surgery typically were more experienced and had better earned run averages than control players. Pitchers who had symptomatic rotator cuff tears that necessitated operative treatment tended to decline gradually in performance leading up to their operations and to improve gradually over the next 3 seasons. In contrast to what we expected, they did not have a greater attrition rate than their control counterparts; however, their performances did not return to preoperative levels over the course of the study.
Vaginal bleeding in late pregnancy
... this page: //medlineplus.gov/ency/patientinstructions/000627.htm Vaginal bleeding in late pregnancy To use the sharing ... JavaScript. One out of 10 women will have vaginal bleeding during their 3rd trimester. At times, it ...
Edwards, Peter; Ebert, Jay; Joss, Brendan; Bhabra, Gev; Ackland, Tim; Wang, Allan
2016-01-01
The incidence of rotator cuff tears increases with age, with full-thickness rotator cuff tears present in approximately 25% of individuals in their sixties, and more than 50% of those in their eighties. While surgery is considered an effective treatment, recurrent tears at the insertion site are common, especially with degenerative tears, which are frequent in the older population. More recently, there has been increasing interest in exercise rehabilitation and physical therapy as a means to manage partial and full thickness tears of the rotator cuff by addressing weakness and functional deficits. Recent studies have suggested that patients opting for physical therapy have demonstrated high satisfaction, an improvement in function, and success in avoiding surgery. When considering the increasing rate of shoulder surgery and the associated economic and social burden rotator cuff surgery places on both the patient and the health care system, non-surgical management such as physical therapy and exercise may, in selected cases, be a treatment alternative to surgical repair. The purpose of this clinical commentary is to provide an overview of rotator cuff pathology and pathogenesis, and to present an evidence-based case for the role of conservative rehabilitation in the management of rotator cuff injuries. Level of Evidence Level 5 PMID:27104061
Does Increased Body Mass Index Influence Outcomes After Rotator Cuff Repair?
Kessler, Katie E; Robbins, Christopher B; Bedi, Asheesh; Carpenter, James E; Gagnier, Joel J; Miller, Bruce S
2018-03-01
To investigate the influence of pre-existing obesity (body mass index [BMI] ≥ 30) on outcomes after rotator cuff repair surgery. We collected data on adult patients who underwent surgical repair for symptomatic full-thickness rotator cuff tears confirmed by imaging between 2012 and 2015. The required follow-up was 3 years. At baseline and 6, 12, 24, and 36 months, the American Shoulder and Elbow Surgeons score, Western Ontario Rotator Cuff index, and visual analog scale pain scores were collected. Complications were assessed by a chart review. Obesity was defined as BMI ≥ 30. Chi-square analysis and Student's t-test examined differences between categorical and continuous variables at baseline. Generalized estimating equations examined the effects of fixed factors on outcome variables longitudinally from baseline to 36 months. Thirty-nine percent of 213 subjects were obese (mean BMI = 29.2; range, 16-48; standard deviation, 5.8). There were no statistically significant differences between obese and nonobese subjects in other baseline characteristics. When controlling for covariates, obese subjects reported no differences in Western Ontario Rotator Cuff, American Shoulder and Elbow Surgeons, or visual analog scale pain scores when compared with nonobese subjects at baseline and over 3 years from surgery. Although obese patients were more likely to have inpatient surgery, there was no difference in the incidence of postoperative complications. Contrary to our hypothesis, obese participants who underwent rotator cuff repair reported no difference in functional outcome or pain scores compared with nonobese participants over 3 years. In addition, obesity was not associated with postoperative complications in this study. However, as we hypothesized, obese participants were more likely than nonobese participants to have repair in the inpatient setting. Level III, retrospective comparative study. Copyright © 2017 Arthroscopy Association of North America
Impact of spine alignment on the rotator cuff in long-term wheelchair users.
Kentar, Yasser; Brunner, Manuela; Bruckner, Thomas; Hug, Andreas; Raiss, Patric; Zeifang, Felix; Loew, Markus; Almansour, Haidara; Akbar, Michael
2018-06-01
We investigated the impact of poor seated posture on the prevalence of rotator cuff tears (RCTs) among wheelchair-dependent individuals with long-standing paraplegia. The study included 319 patients. Lateral radiographs of the spine were collected from a database and analyzed to assess the global spinopelvic alignment (SPA). Magnetic resonance images of both shoulders were obtained to detect the presence of cuff tears. Patients were divided into 2 groups: Group RCT-I included all patients with cuff tears (right, left, or bilateral), whereas group RCT-II consisted exclusively of patients with bilateral cuff tears. We used the classification systems developed by Kendall et al and Roussouly et al to assess the sagittal spine alignment and SPA, respectively. Univariate and multivariate analyses were performed. To fit both models (groups RCT-I and RCT-II) to the data, the 4 spine curves according to Roussouly et al were subdivided into 2 groups: Group SPA-I included both type 1 and type 2, whereas group SPA-II included both type 3 and type 4. Magnetic resonance images showed a cuff tear in 192 patients (60.19%) (group RCT-I). Among those, 37 patients (11.60%) had tears in both shoulders (group RCT-II). In group RCT-I, 70.31% of the patients had a kyphotic-lordotic posture. The kyphotic-lordotic posture, a longer duration, and a more rostral neurologic level of injury were highly associated with cuff tear prevalence. In group RCT-II, the multivariate analysis showed that only the duration of spinal cord injury was significantly associated with RCTs. Thoracic hyperkyphosis was associated with a markedly high rate of RCTs. The data from this study may provide support for developing preventive strategies. Copyright © 2017 Journal of Shoulder and Elbow Surgery Board of Trustees. Published by Elsevier Inc. All rights reserved.
Longo, Umile Giuseppe; Saris, Daniël; Poolman, Rudolf W; Berton, Alessandra; Denaro, Vincenzo
2012-10-01
The aims of this study were to obtain an overview of the methodological quality of studies on the measurement properties of rotator cuff questionnaires and to describe how well various aspects of the design and statistical analyses of studies on measurement properties are performed. A systematic review of published studies on the measurement properties of rotator cuff questionnaires was performed. Two investigators independently rated the quality of the studies using the Consensus-based Standards for the selection of health Measurement Instruments checklist. This checklist was developed in an international Delphi consensus study. Sixteen studies were included, in which two measurement instruments were evaluated, namely the Western Ontario Rotator Cuff Index and the Rotator Cuff Quality-of-Life Measure. The methodological quality of the included studies was adequate on some properties (construct validity, reliability, responsiveness, internal consistency, and translation) but need to be improved on other aspects. The most important methodological aspects that need to be developed are as follows: measurement error, content validity, structural validity, cross-cultural validity, criterion validity, and interpretability. Considering the importance of adequate measurement properties, it is concluded that, in the field of rotator cuff pathology, there is room for improvement in the methodological quality of studies measurement properties. II.
Gender, ethnicity and smoking affect pain and function in patients with rotator cuff tears.
Maher, Anthony; Leigh, Warren; Brick, Matt; Young, Simon; Millar, James; Walker, Cameron; Caughey, Michael
2017-09-01
This study is a collation of baseline demographic characteristics of those presenting for rotator cuff repair in New Zealand, and exploration of associations with preoperative function and pain. Data were obtained from the New Zealand Rotator Cuff Registry; a multicentre, nationwide prospective cohort of rotator cuff repairs undertaken from 1 March 2009 until 31 December 2010. A total of 1383 patients were included in the study. This required complete demographic information, preoperative Flex-SF (functional score) and pain scores. Following univariate analysis, a multivariate model was used. The average age was 58 years (69% males and 11% smokers). New Zealand Europeans made up 90% and Maori 5%. The average preoperative Flex-SF was significantly lower (poorer function) in those over 65 years, females, smokers and Maori, in the non-dominant patients, using a multivariate model. Average preoperative pain scores were significantly worse (higher scores) in females, Maori, Polynesians, smokers, using a multivariate model. This is the largest reported prospective cohort of patients presenting for rotator cuff surgery. Results can be used to understand the effect of rotator cuff tears on the different patients, for example Maori patients who are under-represented, present younger, with more pain and poorer function. © 2017 Royal Australasian College of Surgeons.