Sample records for vaginal cylinder brachytherapy

  1. Dosimetric Effects of Air Pockets Around High-Dose Rate Brachytherapy Vaginal Cylinders

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Richardson, Susan, E-mail: srichardson@radonc.wustl.ed; Palaniswaamy, Geethpriya; Grigsby, Perry W.

    2010-09-01

    Purpose: Most physicians use a single-channel vaginal cylinder for postoperative endometrial cancer brachytherapy. Recent published data have identified air pockets between the vaginal cylinders and the vaginal mucosa. The purpose of this research was to evaluate the incidence, size, and dosimetric effects of these air pockets. Methods and Materials: 25 patients receiving postoperative vaginal cuff brachytherapy with a high-dose rate vaginal cylinders were enrolled in this prospective data collection study. Patients were treated with 6 fractions of 200 to 400 cGy per fraction prescribed at 5 mm depth. Computed tomography simulation for brachytherapy treatment planning was performed for each fraction.more » The quantity, volume, and dosimetric impact of the air pockets surrounding the cylinder were quantified. Results: In 25 patients, a total of 90 air pockets were present in 150 procedures (60%). Five patients had no air pockets present during any of their treatments. The average number of air pockets per patient was 3.6, with the average total air pocket volume being 0.34 cm{sup 3} (range, 0.01-1.32 cm{sup 3}). The average dose reduction to the vaginal mucosa at the air pocket was 27% (range, 9-58%). Ten patients had no air pockets on their first fraction but air pockets occurred in subsequent fractions. Conclusion: Air pockets between high-dose rate vaginal cylinder applicators and the vaginal mucosa are present in the majority of fractions of therapy, and their presence varies from patient to patient and fraction to fraction. The existence of air pockets results in reduced radiation dose to the vaginal mucosa.« less

  2. A novel method for vaginal cylinder treatment planning: a seamless transition to 3D brachytherapy

    PubMed Central

    Wu, Vincent; Wang, Zhou; Patil, Sachin

    2012-01-01

    Purpose Standard treatment plan libraries are often used to ensure a quick turn-around time for vaginal cylinder treatments. Recently there is increasing interest in transitioning from conventional 2D radiograph based brachytherapy to 3D image based brachytherapy, which has resulted in a substantial increase in treatment planning time and decrease in patient through-put. We describe a novel technique that significantly reduces the treatment planning time for CT-based vaginal cylinder brachytherapy. Material and methods Oncentra MasterPlan TPS allows multiple sets of data points to be classified as applicator points which has been harnessed in this method. The method relies on two hard anchor points: the first dwell position in a catheter and an applicator configuration specific dwell position as the plan origin and a soft anchor point beyond the last active dwell position to define the axis of the catheter. The spatial location of various data points on the applicator's surface and at 5 mm depth are stored in an Excel file that can easily be transferred into a patient CT data set using window operations and then used for treatment planning. The remainder of the treatment planning process remains unaffected. Results The treatment plans generated on the Oncentra MasterPlan TPS using this novel method yielded results comparable to those generated on the Plato TPS using a standard treatment plan library in terms of treatment times, dwell weights and dwell times for a given optimization method and normalization points. Less than 2% difference was noticed between the treatment times generated between both systems. Using the above method, the entire planning process, including CT importing, catheter reconstruction, multiple data point definition, optimization and dose prescription, can be completed in ~5–10 minutes. Conclusion The proposed method allows a smooth and efficient transition to 3D CT based vaginal cylinder brachytherapy planning. PMID:23349650

  3. SU-F-T-65: AutomaticTreatment Planning for High-Dose Rate (HDR) Brachytherapy with a VaginalCylinder Applicator

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Zhou, Y; Tan, J; Jiang, S

    Purpose: High dose rate (HDR) brachytherapy treatment planning is conventionally performed in a manual fashion. Yet it is highly desirable to perform computerized automated planning to improve treatment planning efficiency, eliminate human errors, and reduce plan quality variation. The goal of this research is to develop an automatic treatment planning tool for HDR brachytherapy with a cylinder applicator for vaginal cancer. Methods: After inserting the cylinder applicator into the patient, a CT scan was acquired and was loaded to an in-house developed treatment planning software. The cylinder applicator was automatically segmented using image-processing techniques. CTV was generated based on user-specifiedmore » treatment depth and length. Locations of relevant points (apex point, prescription point, and vaginal surface point), central applicator channel coordinates, and dwell positions were determined according to their geometric relations with the applicator. Dwell time was computed through an inverse optimization process. The planning information was written into DICOM-RT plan and structure files to transfer the automatically generated plan to a commercial treatment planning system for plan verification and delivery. Results: We have tested the system retrospectively in nine patients treated with vaginal cylinder applicator. These cases were selected with different treatment prescriptions, lengths, depths, and cylinder diameters to represent a large patient population. Our system was able to generate treatment plans for these cases with clinically acceptable quality. Computation time varied from 3–6 min. Conclusion: We have developed a system to perform automated treatment planning for HDR brachytherapy with a cylinder applicator. Such a novel system has greatly improved treatment planning efficiency and reduced plan quality variation. It also served as a testbed to demonstrate the feasibility of automatic HDR treatment planning for more complicated cases.« less

  4. Image-based multichannel vaginal cylinder brachytherapy for the definitive treatment of gynecologic malignancies in the vagina.

    PubMed

    Gebhardt, Brian J; Vargo, John A; Kim, Hayeon; Houser, Christopher J; Glaser, Scott M; Sukumvanich, Paniti; Olawaiye, Alexander B; Kelley, Joseph L; Edwards, Robert P; Comerci, John T; Courtney-Brooks, Madeleine; Beriwal, Sushil

    2018-06-18

    Brachytherapy is integral to vaginal cancer treatment and is typically delivered using an intracavitary single-channel vaginal cylinder (SCVC) or an interstitial brachytherapy (ISBT) applicator. Multi-channel vaginal cylinder (MCVC) applicators allow for improved organ-at-risk (OAR) sparing compared to SCVC while maintaining target coverage. We present clinical outcomes of patients treated with image-based high dose-rate (HDR) brachytherapy using a MCVC. Sixty patients with vaginal cancer (27% primary vaginal and 73% recurrence from other primaries) were treated with combination external beam radiotherapy (EBRT) and image-based HDR brachytherapy utilizing a MCVC if residual disease thickness was 7 mm or less after EBRT. All pts received 3D image-based BT to a total equivalent dose of 70-80 Gy. The median high-risk clinical target volume was 24.4 cm 3 (interquartile range [IQR], 14.1), with a median dose to 90% of 77.2 Gy (IQR, 2.8). After a median follow-up of 45 months (range, 11-78), the 4-year local-regional control, distant control, DFS, and OS rates were 92.6%, 76.1%, 64.0%, and 67.2%, respectively. The 4-year LRC rates were similar between the primary vaginal (92%) and recurrent (93%) groups (p = 0.290). Pts with lymph node positive disease had a lower rate of distant control at 4 years (22.7% vs. 89.0%, p < 0.001). There were no Grade 3 or higher acute complications. The 4-year rate of late Grade 3 or higher toxicity was 2.7%. Clinical outcomes of pts with primary and recurrent vaginal cancer treated definitively in a systematic manner with combination EBRT with image-guided HDR BT utilizing a MCVC applicator demonstrate high rates of local control and low rates of severe morbidity. The MCVC technique allows interstitial implantation to be avoided in select pts with ≤7 mm residual disease thickness following EBRT while maintaining excellent clinical outcomes with extended 4-year follow-up in this rare malignancy. Copyright © 2018

  5. SU-E-T-366: Clinical Implementation of MR-Guided Vaginal Cylinder Brachytherapy

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Owrangi, A; Jolly, S; Balter, J

    2014-06-01

    Purpose: To evaluate the accuracy of MR-based vaginal brachytherapy source localization using an in-house MR-visible marker versus the alignment of an applicator model to MR images. Methods: Three consecutive patients undergoing vaginal HDR brachytherapy with a plastic cylinder were scanned with both CT and MRI (including T1- and T2- weighted images). An MR-visible source localization marker, consisting of a sealed thin catheter filled with either water (for T2 contrast) or Gd-doped water (for T1 contrast), was assembled shortly before scanning. Clinically, the applicator channel was digitized on CT with an x-ray marker. To evaluate the efficacy of MR-based applicator reconstruction,more » each MR image volume was aligned locally to the CT images based on the region containing the cylinder. Applicator digitization was performed on the MR images using (1) the MR visible marker and (2) alignment of an applicator surface model from Varian's Brachytherapy Planning software to the MRI images. Resulting source positions were compared with the original CT digitization. Results: Although the source path was visualized by the MR marker, the applicator tip proved difficult to identify due to challenges in achieving a watertight seal. This resulted in observed displacements of the catheter tip, at times >1cm. Deviations between the central source positions identified via aligning the applicator surface model to MR and using the xray marker on CT ranged from 0.07 – 0.19 cm and 0.07 – 0.20 cm on T1- weighted and T2-weighted images, respectively. Conclusion: Based on the current study, aligning the applicator model to MRI provides a practical, current approach to perform MR-based brachytherapy planning. Further study is needed to produce catheters with reliably and reproducibly identifiable tips. Attempts are being made to improve catheter seals, as well as to increase the viscosity of the contrast material to decrease fluid mobility inside the catheter.« less

  6. Customized vaginal vault brachytherapy with computed tomography imaging-derived applicator prototyping.

    PubMed

    Wiebe, Ericka; Easton, Harry; Thomas, Gillian; Barbera, Lisa; D'Alimonte, Laura; Ravi, Ananth

    2015-01-01

    A novel customized vaginal brachytherapy mould technique has been developed for clinical use. This image-guided technique provides a brachytherapy applicator solution for irregular vaginal vault configuration and/or a wide vaginal apex relative to the vaginal introitus that would be sub-optimally treated with standard cylinders. The customized vaginal applicator is generated by the following process: CT images are obtained with contrast-soaked vaginal packing in situ to highlight unique anatomical detail. A 3-dimensional digital model is developed from the images and subsequently converted into a custom applicator with the use of stereolithography, which is an additive manufacturing technique whereby layers 50-100 μm thick of resin are deposited and polymerized using a laser to create intricate 3-dimensional objects. The density of the applicator and the dose delivered using the custom applicator were both measured to ensure accurate dosimetry. The CT-based densities of a clinical vaginal cylinder and the cylinder generated using stereolithography were 1.29 ± 0.06 g/cm(3) vs 1.28 ± 0.01 g/cm(3), respectively. The mean measured dose from a representative stereolithographed applicator normalized to dose measured for a single plastic catheter was 99.8 ± 4.2%. In patient dosimetric results indicate improved coverage of the lateral aspect of vaginal vault with the custom cylinder relative to the standard cylinder; 700 cGy vs 328 cGy, respectively, at a representative lateral vaginal dose point, while simultaneously achieving relatively narrow dose distribution in the anterior/posterior direction. Stereolithographic applicator production was available within a clinically acceptable timeframe, and its clinical feasibility and utility has been demonstrated. Copyright © 2015 American Brachytherapy Society. Published by Elsevier Inc. All rights reserved.

  7. Image-Based 3D Treatment Planning for Vaginal Cylinder Brachytherapy: Dosimetric Effects of Bladder Filling on Organs at Risk

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Hung, Jennifer; Shen Sui; De Los Santos, Jennifer F.

    2012-07-01

    Purpose: To investigate the dosimetric effects of bladder filling on organs at risk (OARs) using three-dimensional image-based treatment planning for vaginal cylinder brachytherapy. Methods and Materials: Twelve patients with endometrial or cervical cancer underwent postoperative high-dose rate vaginal cylinder brachytherapy. For three-dimensional planning, patients were simulated by computed tomography with an indwelling catheter in place (empty bladder) and with 180 mL of sterile water instilled into the bladder (full bladder). The bladder, rectum, sigmoid, and small bowel (OARs) were contoured, and a prescription dose was generated for 10 to 35 Gy in 2 to 5 fractions at the surface ormore » at 5 mm depth. For each OAR, the volume dose was defined by use of two different criteria: the minimum dose value in a 2.0-cc volume receiving the highest dose (D{sub 2cc}) and the dose received by 50% of the OAR volume (D{sub 50%}). International Commission on Radiation Units and Measurements (ICRU) bladder and rectum point doses were calculated for comparison. The cylinder-to-bowel distance was measured using the shortest distance from the cylinder apex to the contoured sigmoid or small bowel. Statistical analyses were performed with paired t tests. Results: Mean bladder and rectum D{sub 2cc} values were lower than their respective ICRU doses. However, differences between D{sub 2cc} and ICRU doses were small. Empty vs. full bladder did not significantly affect the mean cylinder-to-bowel distance (0.72 vs. 0.92 cm, p = 0.08). In contrast, bladder distention had appreciable effects on bladder and small bowel volume dosimetry. With a full bladder, the mean small bowel D{sub 2cc} significantly decreased from 677 to 408 cGy (p = 0.004); the mean bladder D{sub 2cc} did not increase significantly (1,179 cGy vs. 1,246 cGy, p = 0.11). Bladder distention decreased the mean D{sub 50%} for both the bladder (441 vs. 279 cGy, p = 0.001) and the small bowel (168 vs. 132 cGy, p = 0

  8. Automated high-dose rate brachytherapy treatment planning for a single-channel vaginal cylinder applicator

    NASA Astrophysics Data System (ADS)

    Zhou, Yuhong; Klages, Peter; Tan, Jun; Chi, Yujie; Stojadinovic, Strahinja; Yang, Ming; Hrycushko, Brian; Medin, Paul; Pompos, Arnold; Jiang, Steve; Albuquerque, Kevin; Jia, Xun

    2017-06-01

    High dose rate (HDR) brachytherapy treatment planning is conventionally performed manually and/or with aids of preplanned templates. In general, the standard of care would be elevated by conducting an automated process to improve treatment planning efficiency, eliminate human error, and reduce plan quality variations. Thus, our group is developing AutoBrachy, an automated HDR brachytherapy planning suite of modules used to augment a clinical treatment planning system. This paper describes our proof-of-concept module for vaginal cylinder HDR planning that has been fully developed. After a patient CT scan is acquired, the cylinder applicator is automatically segmented using image-processing techniques. The target CTV is generated based on physician-specified treatment depth and length. Locations of the dose calculation point, apex point and vaginal surface point, as well as the central applicator channel coordinates, and the corresponding dwell positions are determined according to their geometric relationship with the applicator and written to a structure file. Dwell times are computed through iterative quadratic optimization techniques. The planning information is then transferred to the treatment planning system through a DICOM-RT interface. The entire process was tested for nine patients. The AutoBrachy cylindrical applicator module was able to generate treatment plans for these cases with clinical grade quality. Computation times varied between 1 and 3 min on an Intel Xeon CPU E3-1226 v3 processor. All geometric components in the automated treatment plans were generated accurately. The applicator channel tip positions agreed with the manually identified positions with submillimeter deviations and the channel orientations between the plans agreed within less than 1 degree. The automatically generated plans obtained clinically acceptable quality.

  9. Comparison of doses to the rectum derived from treatment planning system with in-vivo dose values in vaginal vault brachytherapy using cylinder applicators

    PubMed Central

    Obed, Rachel Ibhade; Akinlade, Bidemi Idayat; Ntekim, Atara

    2015-01-01

    Purpose In-vivo measurements to determine doses to organs-at-risk can be an essential part of brachytherapy quality assurance (QA). This study compares calculated doses to the rectum with measured dose values as a means of QA in vaginal vault brachytherapy using cylinder applicators. Material and methods At the Department of Radiotherapy, University College Hospital (UCH), Ibadan, Nigeria, intracavitary brachytherapy (ICBT) was delivered by a GyneSource high-dose-rate (HDR) unit with 60Co. Standard 2D treatment plans were created with HDR basic 2.6 software for prescription doses 5-7 Gy at points 5 mm away from the posterior surface of vaginal cylinder applicators (20, 25, and 30 mm diameters). The LiF:Mg, Ti thermoluminescent dosimeter rods (1 x 6 mm) were irradiated to a dose of 7 Gy on Theratron 60Co machine for calibration purpose prior to clinical use. Measurements in each of 34 insertions involving fourteen patients were performed with 5 TLD-100 rods placed along a re-usable rectal marker positioned in the rectum. The dosimeters were read in Harshaw 3500 TLD reader and compared with doses derived from the treatment planning system (TPS) at 1 cm away from the dose prescription points. Results The mean calculated and measured doses ranged from 2.1-3.8 Gy and 1.2-5.6 Gy with averages of 3.0 ± 0.5 Gy and 3.1 ± 1.1 Gy, respectively, for treatment lengths 2-8 cm along the cylinder-applicators. The mean values correspond to 48.9% and 50.8% of the prescribed doses, respectively. The deviations of the mean in-vivo doses from the TPS values ranged from –1.9 to 2.1 Gy with a p-value of 0.427. Conclusions This study was part of efforts to verify rectal dose obtained from the TPS during vaginal vault brachytherapy. There was no significant difference in the dose to the rectum from the two methods of measurements. PMID:26816506

  10. Optimized Dose Distribution of Gammamed Plus Vaginal Cylinders

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Supe, Sanjay S.; Bijina, T.K.; Varatharaj, C.

    2009-04-01

    Endometrial carcinoma is the most common malignancy arising in the female genital tract. Intracavitary vaginal cuff irradiation may be given alone or with external beam irradiation in patients determined to be at risk for locoregional recurrence. Vaginal cylinders are often used to deliver a brachytherapy dose to the vaginal apex and upper vagina or the entire vaginal surface in the management of postoperative endometrial cancer or cervical cancer. The dose distributions of HDR vaginal cylinders must be evaluated carefully, so that clinical experiences with LDR techniques can be used in guiding optimal use of HDR techniques. The aim of thismore » study was to optimize dose distribution for Gammamed plus vaginal cylinders. Placement of dose optimization points was evaluated for its effect on optimized dose distributions. Two different dose optimization point models were used in this study, namely non-apex (dose optimization points only on periphery of cylinder) and apex (dose optimization points on periphery and along the curvature including the apex points). Thirteen dwell positions were used for the HDR dosimetry to obtain a 6-cm active length. Thus 13 optimization points were available at the periphery of the cylinder. The coordinates of the points along the curvature depended on the cylinder diameters and were chosen for each cylinder so that four points were distributed evenly in the curvature portion of the cylinder. Diameter of vaginal cylinders varied from 2.0 to 4.0 cm. Iterative optimization routine was utilized for all optimizations. The effects of various optimization routines (iterative, geometric, equal times) was studied for the 3.0-cm diameter vaginal cylinder. The effect of source travel step size on the optimized dose distributions for vaginal cylinders was also evaluated. All optimizations in this study were carried for dose of 6 Gy at dose optimization points. For both non-apex and apex models of vaginal cylinders, doses for apex point and

  11. Dosimetric impact of cylinder size in high-dose rate vaginal cuff brachytherapy (VCBT) for primary endometrial cancer.

    PubMed

    Zhang, Hualin; Gopalakrishnan, Mahesh; Lee, Plato; Kang, Zhuang; Sathiaseelan, Vythialingam

    2016-09-08

    The purpose of this study was to evaluate the dosimetric impact of cylinder size in high-dose-rate (HDR) vaginal cuff brachytherapy (VCBT). Sample plans of HDR VCBT in a list of cylinders ranging from 2.5 to 4 cm in diameter at 0.5 cm incre-ment were created and analyzed. The doses were prescribed either at the 0.5cm depth with 5.5 Gy for 4 fractions or at the cylinder surface with 8.8 Gy for 4 frac-tions, in various treatment lengths. A 0.5 cm shell volume called PTV_Eval was contoured for each plan and served as the target volume for dosimetric evaluation. The cumulative and differential dose volume histograms (c-DVH and d-DVH), mean doses (D-mean) and the doses covering 90% (D90), 10% (D10), and 5% (D5) of PTV_Eval were calculated. In the 0.5 cm depth regimen, the DVH curves were found to have shifted toward the lower dose zone when a larger cylinder was used, but in the surface regimen the DVH curves shifted toward the higher dose zone as the cylinder size increased. The D-means of the both regimens were between 6.9 and 7.8 Gy and dependent on the cylinder size but independent of the treatment length. A 0.5 cm variation of diameter could result in a 4% change of D-mean. Average D90s were 5.7 (ranging from 5.6 to 5.8 Gy) and 6.1 Gy (from 5.7 to 6.4 Gy), respectively, for the 0.5 cm and surface regimens. Average D10 and D5 were 9.2 and 11 Gy, respectively, for the 0.5 cm depth regimen, and 8.9 and 9.7 Gy, respectively, for the surface regimen. D-mean, D90, D10, and D5 for other prescription doses could be calculated from the lookup tables of this study. Results indicated that the cylinder size has moderate dosimetric impact, and that both regimens are comparable in dosimetric quality. © 2016 The Authors.

  12. SU-F-19A-03: Dosimetric Advantages in Critical Structure Dose Sparing by Using a Multichannel Cylinder in High Dose Rate Brachytherapy to Treat Vaginal Cuff Cancer

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Syh, J; Syh, J; Patel, B

    2014-06-15

    Purpose: The multichannel cylindrical vaginal applicator is a variation of traditional single channel cylindrical vaginal applicator. The multichannel applicator has additional peripheral channels that provide more flexibility in the planning process. The dosimetric advantage is to reduce dose to adjacent organ at risk (OAR) such as bladder and rectum while maintaining target coverage with the dose optimization from additional channels. Methods: Vaginal HDR brachytherapy plans are all CT based. CT images were acquired in 2 mm thickness to keep integrity of cylinder contouring. The CTV of 5mm Rind with prescribed treatment length was reconstructed from 5mm expansion of inserted cylinder.more » The goal was 95% of CTV covered by 95% of prescribed dose in both single channel planning (SCP)and multichannel planning (MCP) before proceeding any further optimization for dose reduction to critical structures with emphasis on D2cc and V2Gy . Results: This study demonstrated noticeable dose reduction to OAR was apparent in multichannel plans. The D2cc of the rectum and bladder were showing the reduced dose for multichannel versus single channel. The V2Gy of the rectum was 93.72% and 83.79% (p=0.007) for single channel and multichannel respectively (Figure 1 and Table 1). To assure adequate coverage to target while reducing the dose to the OAR without any compromise is the main goal in using multichannel vaginal applicator in HDR brachytherapy. Conclusion: Multichannel plans were optimized using anatomical based inverse optimization algorithm of inverse planning simulation annealing. The optimization solution of the algorithm was to improve the clinical target volume dose coverage while reducing the dose to critical organs such as bladder, rectum and bowels. The comparison between SCP and MCP demonstrated MCP is superior to SCP where the dwell positions were based on geometric array only. It concluded that MCP is preferable and is able to provide certain features superior

  13. Prospective Clinical Trial of Bladder Filling and Three-Dimensional Dosimetry in High-Dose-Rate Vaginal Cuff Brachytherapy

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Stewart, Alexandra J.; Cormack, Robert A.; Lee, Hang

    2008-11-01

    Purpose: To investigate the effect of bladder filling on dosimetry and to determine the best bladder dosimetric parameter for vaginal cuff brachytherapy. Methods and Materials: In this prospective clinical trial, a total of 20 women underwent vaginal cylinder high-dose-rate brachytherapy. The bladder was full for Fraction 2 and empty for Fraction 3. Dose-volume histogram and dose-surface histogram values were generated for the bladder, rectum, and urethra. The midline maximal bladder point (MBP) and the midline maximal rectal point were recorded. Paired t tests, Pearson correlations, and regression analyses were performed. Results: The volume and surface area of the irradiated bladdermore » were significantly smaller when the bladder was empty than when full. Of the several dose-volume histogram and dose-surface histogram parameters evaluated, the bladder maximal dose received by 2 cm{sup 3} of tissue, volume of bladder receiving {>=}50% of the dose, volume of bladder receiving {>=}70% of the dose, and surface area of bladder receiving {>=}50% of the dose significantly predicted for the difference between the empty vs. full filling state. The volume of bladder receiving {>=}70% of the dose and the maximal dose received by 2 cm{sup 3} of tissue correlated significantly with the MBP. Bladder filling did not alter the volume or surface area of the rectum irradiated. However, an empty bladder did result in the nearest point of bowel being significantly closer to the vaginal cylinder than when the bladder was full. Conclusions: Patients undergoing vaginal cuff brachytherapy treated with an empty bladder have a lower bladder dose than those treated with a full bladder. The MBP correlated well with the volumetric assessments of bladder dose and provided a noninvasive method for reporting the MBP dose using three-dimensional imaging. The MBP can therefore be used as a surrogate for complex dosimetry in the clinic.« less

  14. SU-G-201-01: An Automated Treatment Plan Quality Assurance Program for High-Dose Rate (HDR) Brachytherapy with a VaginalCylinder Applicator

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Zhou, Y; Tan, J; Jiang, S

    Purpose: Plan specific quality assurance (QA) is an important step in high dose rate (HDR) brachytherapy to ensure the integrity of a treatment plan. The conventional approach is to assemble a set of plan screen-captures in a document and have an independent plan-checker to verify it. Not only is this approach cumbersome and time-consuming, using a document also limits the items that can be verified, hindering plan quality and patient safety. We have initiated efforts to develop a web-based HDR brachytherapy QA system called AutoBrachy QA, for comprehensive and efficient QA. This abstract reports a new plugin in this systemmore » for the QA of a cylinder HDR brachytherapy treatment. Methods: A cylinder plan QA module was developed using Python. It was plugged into our AutoBrachy QA system. This module extracted information from CT images and treatment plan. Image processing techniques were employed to obtain geometric parameters, e.g. cylinder diameter. A comprehensive set of eight geometrical and eight dosimetric features of the plan were validated against user specified planning parameter, such as prescription value, treatment depth and length, etc. A PDF document was generated, consisting of a summary QA sheet with all the QA results, as well as images showing plan details. Results: The cylinder QA program has been implemented in our clinic. To date, it has been used in 11 patient cases and was able to successfully perform QA tests in all of them. The QA program reduced the average plan QA time from 7 min using conventional manual approach to 0.5 min. Conclusion: Being a new module in our AutoBrachy QA system, an automated treatment plan QA module for cylinder HDR brachytherapy has been successfully developed and clinically implemented. This module improved clinical workflow and plan integrity compared to the conventional manual approach.« less

  15. SU-E-T-579: Impact of Cylinder Size in High-Dose Rate Brachytherapy (HDRBT) for Primary Cancer in the Vagina

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Zhang, H; Gopalakrishnan, M; Lee, P

    2014-06-01

    Purpose: To evaluate the dosimetric impact of cylinder size in high dose rate Brachytherapy for primary vaginal cancers. Methods: Patients treated with HDR vaginal vault radiation in a list of cylinders ranging from 2.5 to 4 cm in diameter at 0.5 cm increment were analyzed. All patients’ doses were prescribed at the 0.5 cm from the vaginal surface with different treatment lengths. A series of reference points were created to optimize the dose distribution. The fraction dose was 5.5 Gy, the treatment was repeated for 4 times in two weeks. A cylinder volume was contoured in each case according tomore » the prescribed treatment length, and then expanded to 5 mm to get a volume Cylinder-5mm-exp. A volume of PTV-Eval was obtained by subtracting the cylinder volume from the Cylinder-5mm-exp. The shell volume, PTV-Eval serves as the target volume for dosimetric evaluation. Results: DVH curves and average doses of PTV-Eval were obtained. Our results indicated that the DVH curves shifted toward higher dose side when larger cylinder was used instead of smaller ones. When 3.0 cm cylinder was used instead of 2.5 cm, for 3.0 cm treatment length, the average dose only increased 1%, from 790 to 799 cGy. However, the average doses for 3.5 and 4 cm cylinders respectively are 932 and 1137 cGy at the same treatment length. For 5.0 cm treatment length, the average dose is 741 cGy for 2.5 cm cylinder, and 859 cGy for 3 cm cylinder. Conclusion: Our data analysis suggests that for the vaginal intracavitary HDRBT, the average dose is at least 35% larger than the prescribed dose in the studied cases; the size of the cylinder will impact the dose delivered to the target volume. The cylinder with bigger diameter tends to deliver larger average dose to the PTV-Eval.« less

  16. American Brachytherapy Society survey regarding practice patterns of postoperative irradiation for endometrial cancer: Current status of vaginal brachytherapy

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Small, William; Erickson, Beth; Kwakwa, Francis M.A.

    2005-12-01

    Purpose: To survey the current postoperative recommendations for radiotherapy (RT) in patients with endometrial cancer, with an emphasis on vaginal brachytherapy (VBT). Methods and Materials: In August 2003, a 32-item questionnaire was mailed to a random sample of 2396 members of the American Society for Therapeutic Radiology and Oncology and the American Brachytherapy Society. The sample excluded members-in-training, physicists, and non-U.S. members. A follow-up mailing was conducted in November 2003. Those who had not treated any patient in the previous year for endometrial carcinoma were instructed to indicate so at the beginning of the questionnaire and return it without respondingmore » to any other item. Responses were tabulated to determine the relative frequency distribution. Results: of the 2396 surveys sent out, 757 were returned, for a response rate of 31.6%. Of those who responded, 551 (72.8%) had performed postoperative irradiation for endometrial cancer and were included in this study. Of the 551 respondents, 99.8% had delivered external beam RT to some endometrial cancer patients. An increasing trend was found toward referrals for VBT; 91.5% of those who treated endometrial cancer performed VBT. The vaginal target most often irradiated was the upper vagina in 40.7%, upper 4-5 cm in 54.5%, and the entire vagina in 4.9%; 21.3% placed clips at the vaginal apex for applicator verification. The maximal dose to the bladder and rectum was recorded in 78.3% and 80.2% of patients, respectively. Of the respondents, 40% did not use low-dose-rate (LDR) VBT. The two most common LDR applicators were Delclos cylinders (29.7%) and Fletcher colpostats (29.3%). The mean boost dose delivered with LDR VBT when prescribed to the surface was 29.9 Gy and when prescribed to 0.5 cm was 23.8 Gy. When LDR therapy was used without external beam RT, the mean dose when prescribed to the surface was 56.8 Gy and when prescribed to 0.5 cm was 47.9 Gy. In 2002, 69.1% of respondents

  17. Determination of spatial dose distribution in UCC treatments with LDR brachytherapy using Monte Carlo methods.

    PubMed

    Benites-Rengifo, Jorge Luis; Vega-Carrillo, Hector Rene

    2018-05-19

    Using Monte Carlos methods, with the MCNP5 code, a gynecological phantom and a vaginal cylinder were modeled. The spatial distribution of absorbed dose rates in Uterine Cervical Cancer treatment through low dose rate brachytherapy was determined. A liquid water gynecology computational phantom, including a vaginal cylinder applicator made of Lucite, was designed. The applicator has a linear array of four radioactive sources of Cesium 137. Around the vaginal cylinder, 13 water spherical cells of 0.5 cm-diameter were modeled to calculate absorbed dose emulating the procedure made by the treatment planning system. The gamma-ray fluence distribution was estimated, as well as the absorbed doses resulting approximately symmetrical for cells located at upper and lower of vaginal cylinder. Obtained results allow the use of the radioactive decay law to determine dose rate for Uterine Cervical Cancer using low dose rate brachytherapy. Copyright © 2018 Elsevier Ltd. All rights reserved.

  18. Adherence to Vaginal Dilation Following High Dose Rate Brachytherapy for Endometrial Cancer

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Friedman, Lois C., E-mail: Lois.Friedman@UHhospitals.org; Abdallah, Rita; Schluchter, Mark

    Purpose: We report demographic, clinical, and psychosocial factors associated with adherence to vaginal dilation and describe the sexual and marital or nonmarital dyadic functioning of women following high dose rate (HDR) brachytherapy for endometrial cancer. Methods and Materials: We retrospectively evaluated women aged 18 years or older in whom early-stage endometrial (IAgr3-IIB) cancers were treated by HDR intravaginal brachytherapy within the past 3.5 years. Women with or without a sexual partner were eligible. Patients completed questionnaires by mail or by telephone assessing demographic and clinical variables, adherence to vaginal dilation, dyadic satisfaction, sexual functioning, and health beliefs. Results: Seventy-eight ofmore » 89 (88%) eligible women with early-stage endometrial cancer treated with HDR brachytherapy completed questionnaires. Only 33% of patients were adherers, based on reporting having used a dilator more than two times per week in the first month following radiation. Nonadherers who reported a perceived change in vaginal dimension following radiation reported that their vaginas were subjectively smaller after brachytherapy (p = 0.013). Adherers reported more worry about their sex lives or lack thereof than nonadherers (p = 0.047). Patients reported considerable sexual dysfunction following completion of HDR brachytherapy. Conclusions: Adherence to recommendations for vaginal dilator use following HDR brachytherapy for endometrial cancer is poor. Interventions designed to educate women about dilator use benefit may increase adherence. Although sexual functioning was compromised, it is likely that this existed before having cancer for many women in our study.« less

  19. Comparison of different treatment planning optimization methods for vaginal HDR brachytherapy with multichannel applicators: A reduction of the high doses to the vaginal mucosa is possible.

    PubMed

    Carrara, Mauro; Cusumano, Davide; Giandini, Tommaso; Tenconi, Chiara; Mazzarella, Ester; Grisotto, Simone; Massari, Eleonora; Mazzeo, Davide; Cerrotta, Annamaria; Pappalardi, Brigida; Fallai, Carlo; Pignoli, Emanuele

    2017-12-01

    A direct planning approach with multi-channel vaginal cylinders (MVCs) used for HDR brachytherapy of vaginal cancers is particularly challenging. Purpose of this study was to compare the dosimetric performances of different forward and inverse methods used for the optimization of MVC-based vaginal treatments for endometrial cancer, with a particular attention to the definition of strategies useful to limit the high doses to the vaginal mucosa. Twelve postoperative vaginal HDR brachytherapy treatments performed with MVCs were considered. Plans were retrospectively optimized with three different methods: Dose Point Optimization followed by Graphical Optimization (DPO + GrO), Inverse Planning Simulated Annealing with two different class solutions as starting conditions (surflPSA and homogIPSA) and Hybrid Inverse Planning Optimization (HIPO). Several dosimetric parameters related to target coverage, hot spot extensions and sparing of organs at risk were analyzed to evaluate the quality of the achieved treatment plans. Dose homogeneity index (DHI), conformal index (COIN) and a further parameter quantifying the proportion of the central catheter loading with respect to the overall loading (i.e., the central catheter loading index: CCLI) were also quantified. The achieved PTV coverage parameters were highly correlated with each other but uncorrelated with the hot spot quantifiers. HomogIPSA and HIPO achieved higher DHIs and CCLIs and lower volumes of high doses than DPO + GrO and surflPSA. Within the investigated optimization methods, HIPO and homoglPSA showed the highest dose homogeneity to the target. In particular, homogIPSA resulted also the most effective in reducing hot spots to the vaginal mucosa. Copyright © 2017 Associazione Italiana di Fisica Medica. Published by Elsevier Ltd. All rights reserved.

  20. Is there a subset of patients with recurrent cancer in the vagina who are not candidates for interstitial brachytherapy that can be treated with multichannel vaginal brachytherapy using graphic optimization?

    PubMed

    Singh, Deepinder P; Bylund, Kevin C; Matloubieh, Ahmad; Mazloom, Ali; Gray, Alexander; Sidhu, Ravinder; Barrette, Lucille; Chen, Yuhchyau

    2015-04-01

    To evaluate recurrent vaginal cancer treated with vaginal brachytherapy (VBT) using graphic optimization in patients not amenable to surgery and interstitial brachytherapy (ISBT). We retrospectively reviewed the records of 5 patients with recurrent cancer in the vagina that were deemed not to be good candidates for ISBT implant because of medical reasons. All patients received computed tomography/magnetic resonance imaging (CT/MRI) based evaluation in addition to a detailed clinical examination, and were noted to have recurrent nodules in the vagina with size ranging from 10-25 mm. Four of the 5 patients had recurrent disease in the vaginal apex, whereas one patient had recurrence in the lateral vaginal wall. Subsequently, all patients were treated with external beam radiation therapy (EBRT) followed by multichannel vaginal cylinder (MVC)-based VBT using graphic optimization for shaping the isodose to improve the clinical target volume (CTV) coverage, as well as to spare the organs at risk (OAR). The dose to the bladder and rectum with regard to 0.1 cc, 1 cc, and 2 cc were recorded. Median age of the patients was 78 years (range 58-86 years). Thickness of the lesions before VBT ranged from 6-15 mm. All patients were followed up with MRI at 3 months. All patients but one demonstrated complete clinical/ radiological response of the tumor. No patient had any grade III/IV toxicity at 24 months. MVC-based VBT using graphic optimization is safe and yields favorable results if used judiciously.

  1. Vaginal cuff dehiscence after intracavitary brachytherapy for endometrial cancer

    PubMed Central

    Shah, Karan; Potkul, Ronald

    2012-01-01

    We describe 2 unusual cases of vaginal dehiscence after intracavitary brachytherapy performed following robotic laparoscopic hysterectomy (RLH) along with their management. This unusual complication, which may be more common because of the robotic procedures, can be prevented by careful examination and possible delay of the onset of brachytherapy, if indicated. Our report reviews techniques of avoiding this complication and suggests that these complications should be discussed with the patients. PMID:23349653

  2. Optimisation techniques in vaginal cuff brachytherapy.

    PubMed

    Tuncel, N; Garipagaoglu, M; Kizildag, A U; Andic, F; Toy, A

    2009-11-01

    The aim of this study was to explore whether an in-house dosimetry protocol and optimisation method are able to produce a homogeneous dose distribution in the target volume, and how often optimisation is required in vaginal cuff brachytherapy. Treatment planning was carried out for 109 fractions in 33 patients who underwent high dose rate iridium-192 (Ir(192)) brachytherapy using Fletcher ovoids. Dose prescription and normalisation were performed to catheter-oriented lateral dose points (dps) within a range of 90-110% of the prescribed dose. The in-house vaginal apex point (Vk), alternative vaginal apex point (Vk'), International Commission on Radiation Units and Measurements (ICRU) rectal point (Rg) and bladder point (Bl) doses were calculated. Time-position optimisations were made considering dps, Vk and Rg doses. Keeping the Vk dose higher than 95% and the Rg dose less than 85% of the prescribed dose was intended. Target dose homogeneity, optimisation frequency and the relationship between prescribed dose, Vk, Vk', Rg and ovoid diameter were investigated. The mean target dose was 99+/-7.4% of the prescription dose. Optimisation was required in 92 out of 109 (83%) fractions. Ovoid diameter had a significant effect on Rg (p = 0.002), Vk (p = 0.018), Vk' (p = 0.034), minimum dps (p = 0.021) and maximum dps (p<0.001). Rg, Vk and Vk' doses with 2.5 cm diameter ovoids were significantly higher than with 2 cm and 1.5 cm ovoids. Catheter-oriented dose point normalisation provided a homogeneous dose distribution with a 99+/-7.4% mean dose within the target volume, requiring time-position optimisation.

  3. SU-E-T-149: Brachytherapy Patient Specific Quality Assurance for a HDR Vaginal Cylinder Case

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Barbiere, J; Napoli, J; Ndlovu, A

    2015-06-15

    Purpose: Commonly Ir-192 HDR treatment planning system commissioning is only based on a single absolute measurement of source activity supplemented by tabulated parameters for multiple factors without independent verification that the planned distribution corresponds to the actual delivered dose. The purpose on this work is to present a methodology using Gafchromic film with a statistically valid calibration curve that can be used to validate clinical HDR vaginal cylinder cases by comparing the calculated plan dose distribution in a plane with the corresponding measured planar dose. Methods: A vaginal cylinder plan was created with Oncentra treatment planning system. The 3D dosemore » matrix was exported to a Varian Eclipse work station for convenient extraction of a 2D coronal dose plane corresponding to the film position. The plan was delivered with a sheet of Gafchromic EBT3 film positioned 1mm from the catheter using an Ir-192 Nucletron HDR source. The film was then digitized with an Epson 10000 XL color scanner. Film analysis is performed with MatLab imaging toolbox. A density to dose calibration curve was created using TG43 formalism for a single dwell position exposure at over 100 points for statistical accuracy. The plan and measured film dose planes were registered using a known dwell position relative to four film marks. The plan delivered 500 cGy to points 2 cm from the sources. Results: The distance to agreement of the 500 cGy isodose between the plan and film measurement laterally was 0.5 mm but can be as much as 1.5 mm superior and inferior. The difference between the computed plan dose and film measurement was calculated per pixel. The greatest errors up to 50 cGy are near the apex. Conclusion: The methodology presented will be useful to implement more comprehensive quality assurance to verify patient-specific dose distributions.« less

  4. Vaginal dose de-escalation in image guided adaptive brachytherapy for locally advanced cervical cancer.

    PubMed

    Mohamed, Sandy; Lindegaard, Jacob Christian; de Leeuw, Astrid A C; Jürgenliemk-Schulz, Ina; Kirchheiner, Kathrin; Kirisits, Christian; Pötter, Richard; Tanderup, Kari

    2016-09-01

    Vaginal stenosis is a major problem following radiotherapy in cervical cancer. We investigated a new dose planning strategy for vaginal dose de-escalation (VDD). Fifty consecutive locally advanced cervical cancer patients without lower or middle vaginal involvement at diagnosis from 3 institutions were analysed. External beam radiotherapy was combined with MRI-guided brachytherapy. VDD was obtained by decreasing dwell times in ovoid/ring and increasing dwell times in tandem/needles. The aim was to maintain the target dose (D90 of HR-CTV⩾85Gy EQD2) while reducing the dose to the surface of the vagina to <140% of the physical fractional brachytherapy dose corresponding to a total EQD2 of 85Gy. The mean vaginal loading (ovoid/ring) was reduced from 51% to 33% of the total loading with VDD, which significantly reduced the dose to the vaginal dose points (p<0.001) without compromising the target dose. The dose to the ICRU recto-vaginal point was reduced by a mean of 4±4Gy EQD2 (p<0.001), while doses to bladder and rectum (D 2cm 3 ) were reduced by 2±2Gy and 3±2Gy, respectively (p<0.001). VDD significantly reduces dose to the upper vagina which is expected to result in reduction of vaginal stenosis. Copyright © 2016 Elsevier Ireland Ltd. All rights reserved.

  5. Adjuvant Vaginal Brachytherapy for Early Stage Endometrial Cancer: A Comprehensive Review

    PubMed Central

    Harkenrider, Matthew M; Block, Alec M; Alektiar, Kaled M; Gaffney, David K; Jones, Ellen; Klopp, Ann; Viswanathan, Akila N; Small, William

    2017-01-01

    This article aims to review the risk stratification of endometrial cancer, treatment rationale, outcomes, treatment planning, and treatment recommendations of vaginal brachytherapy (VBT) in the post-operative management of endometrial cancer patients. The authors performed a thorough review of the literature and reference pertinent articles pertaining to the aims of this review. Adjuvant VBT for early stage endometrial cancer patients results in very low rates of vaginal recurrence (0–3.1%) with low rates of late toxicity which are primarily vaginal in nature. PORTEC-2 supports that VBT results in non-inferior rates of vaginal recurrence compared to external beam radiotherapy (EBRT) for the treatment of high-intermediate risk patients. VBT as a boost following EBRT, in combination with chemotherapy, and for high-risk histologies have shown excellent results as well though randomized data do not exist supporting VBT boost. There are many different applicators, dose-fractionation schedules, and treatment planning techniques which all result in favorable clinical outcomes and low rates of toxicity. Recommendations have been published by the American Brachytherapy Society and the American Society of Radiation Oncology to help guide practitioners in the use of VBT. Data support that patients and physicians both prefer joint decision-making regarding the use of VBT, and patients often desire additional treatment for a marginal benefit in risk of recurrence. Discussions regarding adjuvant therapy for endometrial cancer are best performed in a multi-disciplinary setting and patients should be counseled properly regarding the risks and benefits of adjuvant therapy. PMID:27260082

  6. 360-degree 3D transvaginal ultrasound system for high-dose-rate interstitial gynaecological brachytherapy needle guidance

    NASA Astrophysics Data System (ADS)

    Rodgers, Jessica R.; Surry, Kathleen; D'Souza, David; Leung, Eric; Fenster, Aaron

    2017-03-01

    Treatment for gynaecological cancers often includes brachytherapy; in particular, in high-dose-rate (HDR) interstitial brachytherapy, hollow needles are inserted into the tumour and surrounding area through a template in order to deliver the radiation dose. Currently, there is no standard modality for visualizing needles intra-operatively, despite the need for precise needle placement in order to deliver the optimal dose and avoid nearby organs, including the bladder and rectum. While three-dimensional (3D) transrectal ultrasound (TRUS) imaging has been proposed for 3D intra-operative needle guidance, anterior needles tend to be obscured by shadowing created by the template's vaginal cylinder. We have developed a 360-degree 3D transvaginal ultrasound (TVUS) system that uses a conventional two-dimensional side-fire TRUS probe rotated inside a hollow vaginal cylinder made from a sonolucent plastic (TPX). The system was validated using grid and sphere phantoms in order to test the geometric accuracy of the distance and volumetric measurements in the reconstructed image. To test the potential for visualizing needles, an agar phantom mimicking the geometry of the female pelvis was used. Needles were inserted into the phantom and then imaged using the 3D TVUS system. The needle trajectories and tip positions in the 3D TVUS scan were compared to their expected values and the needle tracks visualized in magnetic resonance images. Based on this initial study, 360-degree 3D TVUS imaging through a sonolucent vaginal cylinder is a feasible technique for intra-operatively visualizing needles during HDR interstitial gynaecological brachytherapy.

  7. Adjuvant vaginal brachytherapy as a part of management in early endometrial cancer.

    PubMed

    Kellas-Ślęczka, Sylwia; Wojcieszek, Piotr; Białas, Brygida

    2012-12-01

    Endometrial cancer is the most frequent cancer of female genital tract. Metro- and menorrhagia or postmenopausal bleeding results in its early presentation. It allows radical treatment. However, controversies remain on surgery coverage or adjuvant therapies in early endometrial women cancer. Optimal management should minimize intervention instead of aggressive approach, as showed by recent studies. There is a role for brachytherapy as an adjuvant irradiation. Crucial publications including PORTEC-1, GOG 99, MRC ASTEC, ASTEC/EN.5, PORTEC-2 or Italian lymphadenectomy trial are discussed. Moreover, there is attention paid on adjuvant vaginal brachytherapy analyses for the past fifteen years.

  8. Adjuvant vaginal brachytherapy as a part of management in early endometrial cancer

    PubMed Central

    Wojcieszek, Piotr; Białas, Brygida

    2012-01-01

    Endometrial cancer is the most frequent cancer of female genital tract. Metro- and menorrhagia or postmenopausal bleeding results in its early presentation. It allows radical treatment. However, controversies remain on surgery coverage or adjuvant therapies in early endometrial women cancer. Optimal management should minimize intervention instead of aggressive approach, as showed by recent studies. There is a role for brachytherapy as an adjuvant irradiation. Crucial publications including PORTEC-1, GOG 99, MRC ASTEC, ASTEC/EN.5, PORTEC-2 or Italian lymphadenectomy trial are discussed. Moreover, there is attention paid on adjuvant vaginal brachytherapy analyses for the past fifteen years. PMID:23378855

  9. The Role of Vaginal Brachytherapy in the Treatment of Surgical Stage I Papillary Serous or Clear Cell Endometrial Cancer

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Barney, Brandon M., E-mail: barney.brandon@mayo.edu; Petersen, Ivy A.; Mariani, Andrea

    2013-01-01

    Objectives: The optimal adjuvant therapy for International Federation of Gynecology and Obstetrics (FIGO) stage I papillary serous (UPSC) or clear cell (CC) endometrial cancer is unknown. We report on the largest single-institution experience using adjuvant high-dose-rate vaginal brachytherapy (VBT) for surgically staged women with FIGO stage I UPSC or CC endometrial cancer. Methods and Materials: From 1998-2011, 103 women with FIGO 2009 stage I UPSC (n=74), CC (n=21), or mixed UPSC/CC (n=8) endometrial cancer underwent total abdominal hysterectomy with bilateral salpingo-oophorectomy followed by adjuvant high-dose-rate VBT. Nearly all patients (n=98, 95%) also underwent extended lymph node dissection of pelvic andmore » paraortic lymph nodes. All VBT was performed with a vaginal cylinder, treating to a dose of 2100 cGy in 3 fractions. Thirty-five patients (34%) also received adjuvant chemotherapy. Results: At a median follow-up time of 36 months (range, 1-146 months), 2 patients had experienced vaginal recurrence, and the 5-year Kaplan Meier estimate of vaginal recurrence was 3%. The rates of isolated pelvic recurrence, locoregional recurrence (vaginal + pelvic), and extrapelvic recurrence (including intraabdominal) were similarly low, with 5-year Kaplan-Meier estimates of 4%, 7%, and 10%, respectively. The estimated 5-year overall survival was 84%. On univariate analysis, delivery of chemotherapy did not affect recurrence or survival. Conclusions: VBT is effective at preventing vaginal relapse in women with surgical stage I UPSC or CC endometrial cancer. In this cohort of patients who underwent comprehensive surgical staging, the risk of isolated pelvic or extrapelvic relapse was low, implying that more extensive adjuvant radiation therapy is likely unnecessary.« less

  10. Selective perturbation of in vivo linear energy transfer using high- Z vaginal applicators for Cf-252 brachytherapy

    NASA Astrophysics Data System (ADS)

    Rivard, M. J.; Evans, K. E.; Leal, L. C.; Kirk, B. L.

    2004-01-01

    Californium-252 ( 252Cf) brachytherapy sources emit both neutrons and photons, and have the potential to vastly improve the current standard-of-practice for brachytherapy. While hydrogenous materials readily attenuate the 252Cf fission energy neutrons, high- Z materials are utilized to attenuate the 252Cf gamma-rays. These differences in shielding materials may be exploited when treating with a vaginal applicator to possibly improve patient survival through perturbation of the in vivo linear energy transfer radiation.

  11. MRI-Based Evaluation of the Vaginal Cuff in Brachytherapy Planning: Are We Missing the Target?

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Chapman, Christina Hunter; Prisciandaro, Joann I.; Maturen, Katherine E.

    2016-06-01

    Purpose: Although recurrences and toxicity occur after vaginal cuff (VC) brachytherapy, little is known about dosimetry due to the inability to clearly visualize the VC on computed tomography (CT). T2-weighted (T2W) magnetic resonance imaging (MRI) is superior to CT in this setting, and we hypothesized that it could provide previously unascertainable dosimetric information. Methods and Materials: In a cohort of 32 patients who underwent cylinder-based brachytherapy for endometrial cancer with available MR simulation images, the VC was retrospectively contoured on T2W images, and cases were replanned to treat the upper VC to a dose of 7 Gy/fraction prescribed to 5 mm. Relevantmore » dose-volume parameters for the VC were calculated. Results: T2W MRI identified significant underdosing not observed on CT or T1-weighted imaging. Over two-thirds (69%) of patients had at least 1 cm{sup 3} of VC that received less than 75% of the prescription dose and half (50%) of patients had a least 1 cm{sup 3} of VC that received less than 50% of the prescription dose. The mean minimum point dose to the VC was 2.4 Gy, or 34% of the intended prescription dose (range: 0.53-6.4 Gy). Conclusions: We identified previously unreported VC underdosing in over two-thirds of our patients, with most of these patients having volumes of undistended VC that received less than half of the prescription dose. The maximum dimension was along the craniocaudal axis in some patients or left-right/anterior-posterior axis in others, suggesting that suture material may be restricting access to the vaginal apex and that alternative applicators may be needed when the diameter of the apex is larger than the introitus. Additional follow-up will be needed to determine whether underdosing is associated with isolated VC failure or whether low failure rates across the cohort suggest that some patients are being exposed to excessive dose and unnecessary risk of toxicity.« less

  12. Therapeutic analysis of high-dose-rate {sup 192}Ir vaginal cuff brachytherapy for endometrial cancer using a cylindrical target volume model and varied cancer cell distributions

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Zhang, Hualin, E-mail: hualin.zhang@northwestern.edu; Donnelly, Eric D.; Strauss, Jonathan B.

    Purpose: To evaluate high-dose-rate (HDR) vaginal cuff brachytherapy (VCBT) in the treatment of endometrial cancer in a cylindrical target volume with either a varied or a constant cancer cell distributions using the linear quadratic (LQ) model. Methods: A Monte Carlo (MC) technique was used to calculate the 3D dose distribution of HDR VCBT over a variety of cylinder diameters and treatment lengths. A treatment planning system (TPS) was used to make plans for the various cylinder diameters, treatment lengths, and prescriptions using the clinical protocol. The dwell times obtained from the TPS were fed into MC. The LQ model wasmore » used to evaluate the therapeutic outcome of two brachytherapy regimens prescribed either at 0.5 cm depth (5.5 Gy × 4 fractions) or at the vaginal mucosal surface (8.8 Gy × 4 fractions) for the treatment of endometrial cancer. An experimentally determined endometrial cancer cell distribution, which showed a varied and resembled a half-Gaussian distribution, was used in radiobiology modeling. The equivalent uniform dose (EUD) to cancer cells was calculated for each treatment scenario. The therapeutic ratio (TR) was defined by comparing VCBT with a uniform dose radiotherapy plan in term of normal cell survival at the same level of cancer cell killing. Calculations of clinical impact were run twice assuming two different types of cancer cell density distributions in the cylindrical target volume: (1) a half-Gaussian or (2) a uniform distribution. Results: EUDs were weakly dependent on cylinder size, treatment length, and the prescription depth, but strongly dependent on the cancer cell distribution. TRs were strongly dependent on the cylinder size, treatment length, types of the cancer cell distributions, and the sensitivity of normal tissue. With a half-Gaussian distribution of cancer cells which populated at the vaginal mucosa the most, the EUDs were between 6.9 Gy × 4 and 7.8 Gy × 4, the TRs were in the range from (5.0){sup 4} to

  13. Vaginal Dose Is Associated With Toxicity in Image Guided Tandem Ring or Ovoid-Based Brachytherapy.

    PubMed

    Susko, Matthew; Craciunescu, Oana; Meltsner, Sheridan; Yang, Yun; Steffey, Beverly; Cai, Jing; Chino, Junzo

    2016-04-01

    To calculate vaginal doses during image guided brachytherapy with volume-based metrics and correlate with long-term vaginal toxicity. In this institutional review board-approved study, institutional databases were searched to identify women undergoing computed tomography and/or magnetic resonance-guided brachytherapy at the Duke Cancer Center from 2009 to 2015. All insertions were contoured to include the vagina as a 3-dimensional structure. All contouring was performed on computed tomography or magnetic resonance imaging and used a 0.4-cm fixed brush to outline the applicator and/or packing, expanded to include any grossly visible vagina. The surface of the cervix was specifically excluded from the contour. High-dose-rate (HDR) and low-dose-rate (LDR) doses were converted to the equivalent dose in 2-Gy fractions using an α/β of 3 for late effects. The parameters D0.1cc, D1cc, and D2cc were calculated for all insertions and summed with prior external beam therapy. Late and subacute toxicity to the vagina were determined by the Common Terminology Criteria for Adverse Events version 4.0 and compared by the median and 4th quartile doses, via the log-rank test. Univariate and multivariate hazard ratios were calculated via Cox regression. A total of 258 insertions in 62 women who underwent definitive radiation therapy including brachytherapy for cervical (n=48) and uterine cancer (n=14) were identified. Twenty HDR tandem and ovoid, 32 HDR tandem and ring, and 10 LDR tandem and ovoid insertions were contoured. The median values (interquartile ranges) for vaginal D0.1cc, D1cc, and D2cc were 157.9 (134.4-196.53) Gy, 112.6 (96.7-124.6) Gy, and 100.5 (86.8-108.4) Gy, respectively. At the 4th quartile cutoff of 108 Gy for D2cc, the rate of late grade 1 toxicity at 2 years was 61.2% (95% confidence interval [CI] 43.0%-79.4%) below 108 Gy and 83.9% (63.9%-100%) above (P=.018); grade 2 or greater toxicity was 36.2% (95% CI 15.8%-56.6%) below 108 Gy and 70.7% (95% CI 45

  14. High Dose-Rate Intracavitary Brachytherapy for Cervical Carcinomas With Lower Vaginal Infiltration

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Kazumoto, Tomoko; Kato, Shingo; Tabushi, Katsuyoshi

    2007-11-15

    Purpose: This report presents the clinical applications of an automated treatment-planning program of high-dose-rate intracavitary brachytherapy (HDR-ICBT) for advanced uterine cervical cancer infiltrating the parametrium and the lower vagina. Methods and Materials: We adopted HDR-ICBT under optimized dose distribution for 22 cervical cancer patients with tumor infiltration of the lower half of the vagina. All patients had squamous cell carcinoma with International Federation of Gynecology and Obstetrics clinical stages IIB-IVA. After whole pelvic external beam irradiation with a median dose of 30.6 Gy, a conventional ICBT was applied as 'pear-shaped' isodose curve. Then 3-4 more sessions per week of thismore » new method of ICBT were performed. With a simple determination of the treatment volume, the cervix-parametrium, and the lower vagina were covered automatically and simultaneously by this program, that was designated as 'utero-vaginal brachytherapy'. The mean follow-up period was 87.4 months (range, 51.8-147.9 months). Results: Isodose curve for this program was 'galaxy-shaped'. Five-year local-progression-free survival and overall survival rates were 90.7% and 81.8%, respectively. Among those patients with late complications higher than Grade 2 Radiation Therapy Oncology Group/European Organization for Research and Treatment of Cancer morbidity score, only one (4.5%) developed severe proctitis. Conclusions: Because of the favorable treatment outcomes, this treatment-planning program with a simplified target-volume based dosimetry was proposed for cervical cancer with lower vaginal infiltration.« less

  15. Determination of Prognostic Factors for Vaginal Mucosal Toxicity Associated With Intravaginal High-Dose Rate Brachytherapy in Patients With Endometrial Cancer

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Bahng, Agnes Y.; Dagan, Avner; Bruner, Deborah W.

    2012-02-01

    Purpose: The objective of this study was to determine the patient- and treatment-related prognostic factors associated with vaginal toxicity in patients who received intravaginal high dose rate (HDR) brachytherapy alone as adjuvant treatment for endometrial cancer. Secondary goals of this study included a quantitative assessment of optimal dilator use frequency and a crude assessment of clinical predictors for compliant dilator use. Methods and Materials: We retrospectively reviewed the charts of 100 patients with histologically confirmed endometrial cancer who underwent total hysterectomy and bilateral salpingo-oophorectomy with or without lymph node dissection and adjuvant intravaginal brachytherapy between 1995 and 2009 at themore » Hospital of University of Pennsylvania. The most common treatment regimen used was 21 Gy in three fractions (71 patients). Symptoms of vaginal mucosal toxicity were taken from the history and physical exams noted in the patients' charts and were graded according to the Common Toxicity Criteria for Adverse Events v. 4.02. Results: The incidence of Grade 1 or asymptomatic vaginal toxicity was 33% and Grade 2-3 or symptomatic vaginal toxicity was 14%. Multivariate analysis of age, active length, and dilator use two to three times a week revealed odds ratios of 0.93 (p = 0.013), 3.96 (p = 0.008), and 0.17 (p = 0.032) respectively. Conclusion: Increasing age, vaginal dilator use of at least two to three times a week, and shorter active length were found to be significantly associated with a decreased risk of vaginal stenosis. Future prospective studies are necessary to validate our findings.« less

  16. SU-G-TeP2-10: Feasibility of Newly Designed Applicator for High Dose Rate Brachytherapy Treatment of Patients with Vaginal Vault Recurrence

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Lee, V; Wong, M; Chan, M

    Purpose: To compare the dose of an in-house 3D-printed gynecology applicator (TMHGA) for vaginal vault recurrence of corpus cancer patients after operation for high dose rate brachytherapy treatment with commercially available applicators. Methods: A newly designed applicator is made from 3D-printing methods using ABSM30i. The isodose of the applicator is compared with Elekta multi-channel (MC) applicator and titanium Rotterdam applicator with coupling central tube and vaginal cylinder (RC). Three plans are created using three applicators in a CT set of water phantom. The applicators are anchored using the applicator library and implant library in the Elekta Oncentra treatment planning systemmore » (ver.4.5). The rectum is mimicked by creating a 2cm diameter cylinder, with a distance 1mm posteriorly away from the high risk CTV (HR-CTV). Similarly, the bladder is replicated by a 6cm diameter cylinder with distance 1mm anteriorly from the HR-CTV. Three plans are all normalized 1.5cm superior, 0.5cm anterior and 0.5cm posterior of the applicator surface. By fixing D90 of HR-CTV to 6Gy, the D2cc of rectum and bladder of three plans are compared. Results: The D2cc of the bladder for using TMHGA is lower than MC and RC by 14.0% and 11.9% respectively. While the D2cc of the rectum for using TMHGA is lower than MC and RC by 18.9% and 12.4% respectively. The total treatment time of TMHGA plan is shorter than MC and RC by 11.2% and 12.9%. Conclusion: The applicator created via 3D printing delivers a lower dose to the bladder and the rectum while keeping the same coverage to HR-CTV as other commercially available applicators. Additionally, the new applicator resulted in a reduction of treatment time, which is always welcome.« less

  17. Optimizing Local Control in High‐Grade Uterine Sarcoma: Adjuvant Vaginal Vault Brachytherapy as Part of a Multimodal Treatment

    PubMed Central

    Annede, Pierre; Gouy, Sébastien; Mazeron, Renaud; Bentivegna, Enrica; Maroun, Pierre; Petit, Claire; Dumas, Isabelle; Leary, Alexandra; Genestie, Catherine; Lhommé, Catherine; Deutsch, Eric; Morice, Philippe; Pautier, Patricia; Haie‐Meder, Christine

    2017-01-01

    Abstract Purpose. The phase III European Organization for Research and Treatment of Cancer 55874 study has shown that external beam radiotherapy (EBRT) given as adjuvant treatment decreased locoregional recurrences from 40% to 20% in patients (pts) with localized uterine sarcomas (US). No data exist, however, on the place of brachytherapy (BT). Material and Methods. We conducted a single‐center retrospective analysis of pts receiving adjuvant BT of the vaginal vault based on the vaginal mold technique as part of their multimodal adjuvant treatment for a high‐grade US from 1985 to 2015. Treatment characteristics, patterns of relapse, and toxicity were examined. Results. Median follow‐up time was 5.5 years. A total of 98 pts with high‐grade US were identified: 81 leiomyosarcomas and 17 undifferentiated sarcomas. Postoperative chemotherapy was delivered in 53 pts. Median dose of EBRT was 45 Gy in 25 fractions. High‐dose rate, low‐dose rate, and pulsed‐dose rate techniques were used in 66, 31, and 1 pts, respectively. At last follow‐up, six pts (6.1%) experienced a locoregional relapse as first event. The International Federation of Gynecology and Obstetrics stage and the tumor size were associated with a higher probability of local relapse. When focusing on pts with stage I‐III disease, 5‐year overall survival was 77% (95% confidence interval: 67%–87%) and 5‐year survival without locoregional failure was 91% (83%–98%). Toxicities were mild to moderate, with only four acute grade 3 toxicities and two grade 3 late effects. Conclusion. Vaginal vault BT as part of a multimodal adjuvant treatment was associated with a high locoregional control rate and with acceptable side effects in localized high‐grade US. Implications for Practice. This study suggests that an aggressive adjuvant treatment combining chemotherapy and pelvic external beam radiotherapy followed with a brachytherapy of the vaginal vault is associated with a high locoregional

  18. MCNP modelling of vaginal and uterine applicators used in intracavitary brachytherapy and comparison with radiochromic film measurements

    NASA Astrophysics Data System (ADS)

    Ceccolini, E.; Gerardy, I.; Ródenas, J.; van Dycke, M.; Gallardo, S.; Mostacci, D.

    Brachytherapy is an advanced cancer treatment that is minimally invasive, minimising radiation exposure to the surrounding healthy tissues. Microselectron© Nucletron devices with 192Ir source can be used for gynaecological brachytherapy, in patients with vaginal or uterine cancer. Measurements of isodose curves have been performed in a PMMA phantom and compared with Monte Carlo calculations and TPS (Plato software of Nucletron BPS 14.2) evaluation. The isodose measurements have been performed with radiochromic films (Gafchromic EBT©). The dose matrix has been obtained after digitalisation and use of a dose calibration curve obtained with a 6 MV photon beam provided by a medical linear accelerator. A comparison between the calculated and the measured matrix has been performed. The calculated dose matrix is obtained with a simulation using the MCNP5 Monte Carlo code (F4MESH tally).

  19. SU-E-T-10: A Clinical Implementation and the Dosimetric Evidence in High Dose Rate Vaginal Multichannel Applicator Brachytherapy

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Syh, J; Syh, J; Patel, B

    2015-06-15

    Purpose: The multichannel cylindrical applicator has a distinctive modification of the traditional single channel cylindrical applicator. The novel multichannel applicator has additional peripheral channels that provide more flexibility both in treatment planning process and outcomes. To protect by reducing doses to adjacent organ at risk (OAR) while maintaining target coverage with inverse plan optimization are the goals for such novel Brachytherapy device. Through a series of comparison and analysis of reults in more than forty patients who received HDR Brachytherapy using multichannel vaginal applicator, this procedure has been implemented in our institution. Methods: Multichannel planning was CT image based. Themore » CTV of 5mm vaginal cuff rind with prescribed length was well reconstructed as well as bladder and rectum. At least D95 of CTV coverage is 95% of prescribed dose. Multichannel inverse plan optimization algorithm not only shapes target dose cloud but set dose avoids to OAR’s exclusively. The doses of D2cc, D5cc and D5; volume of V2Gy in OAR’s were selected to compare with single channel results when sole central channel is only possibility. Results: Study demonstrates plan superiorly in OAR’s doe reduction in multi-channel plan. The D2cc of the rectum and bladder were showing a little lower for multichannel vs. single channel. The V2Gy of the rectum was 93.72% vs. 83.79% (p=0.007) for single channel vs. multichannel respectively. Absolute reduced mean dose of D5 by multichannel was 17 cGy (s.d.=6.4) and 44 cGy (s.d.=15.2) in bladder and rectum respectively. Conclusion: The optimization solution in multichannel was to maintain D95 CTV coverage while reducing the dose to OAR’s. Dosimetric advantage in sparing critical organs by using a multichannel applicator in HDR Brachytherapy treatment of the vaginal cuff is so promising and has been implemented clinically.« less

  20. Toward a 3D transrectal ultrasound system for verification of needle placement during high-dose-rate interstitial gynecologic brachytherapy.

    PubMed

    Rodgers, Jessica Robin; Surry, Kathleen; Leung, Eric; D'Souza, David; Fenster, Aaron

    2017-05-01

    Treatment for gynecologic cancers, such as cervical, recurrent endometrial, and vaginal malignancies, commonly includes external-beam radiation and brachytherapy. In high-dose-rate (HDR) interstitial gynecologic brachytherapy, radiation treatment is delivered via hollow needles that are typically inserted through a template on the perineum with a cylinder placed in the vagina for stability. Despite the need for precise needle placement to minimize complications and provide optimal treatment, there is no standard intra-operative image-guidance for this procedure. While some image-guidance techniques have been proposed, including magnetic resonance (MR) imaging, X-ray computed tomography (CT), and two-dimensional (2D) transrectal ultrasound (TRUS), these techniques have not been widely adopted. In order to provide intra-operative needle visualization and localization during interstitial brachytherapy, we have developed a three-dimensional (3D) TRUS system. This study describes the 3D TRUS system and reports on the system validation and results from a proof-of-concept patient study. To obtain a 3D TRUS image, the system rotates a conventional 2D endocavity transducer through 170 degrees in 12 s, reconstructing the 2D frames into a 3D image in real-time. The geometry of the reconstruction was validated using two geometric phantoms to ensure the accuracy of the linear measurements in each of the image coordinate directions and the volumetric accuracy of the system. An agar phantom including vaginal and rectal canals, as well as a model uterus and tumor, was designed and used to test the visualization and localization of the interstitial needles under idealized conditions by comparing the needles' positions between the 3D TRUS scan and a registered MR image. Five patients undergoing HDR interstitial gynecologic brachytherapy were imaged using the 3D TRUS system following the insertion of all needles. This image was manually, rigidly registered to the clinical

  1. Vulval and Vaginal Rhabdomyosarcoma in Children: Update and Reappraisal of Institut Gustave Roussy Brachytherapy Experience

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Magne, Nicolas; Oberlin, Odile; Martelli, Helene

    2008-11-01

    Purpose: To report the Institut Gustave Roussy brachytherapy (BT) experience in the management of vulval and vaginal rhabdomyosarcoma with special emphasis on long-term outcome. Patients and Methods: Between 1971 and 2005, the data concerning 39 girls who had undergone BT as a part of their treatment were retrospectively analyzed. Of the 39 girls, 20 had been treated before 1990, when the BT volume encompassed the initial tumor extension. After 1990, only residual disease was included in the BT volume. Side effects were classified using the Common Terminology Criteria for Adverse Events, version 3.0. Results: The median age was 16.3 monthsmore » at diagnosis. Vaginal or vulvar rhabdomyosarcoma was diagnosed in 26 and 6 patients, respectively. The median follow-up was 8.4 years. The 5-year overall survival rate was 91%. Of the 39 patients, 6 developed a relapse. Of the 20 patients treated before 1990, 6 experienced Grade 1-2 renal/genitourinary function symptoms and 75% developed sequelae, in the form of vaginal or urethral sclerosis or stenosis. Four patients received follow-up treatment for psychological disorders. Of the 19 patients treated after 1990, 2 developed acute side effects, with maximal Grade 1-2 renal/genitourinary function symptoms, and 20% developed vaginal or urethral sclerosis or stenosis. Two cases of psychological disturbances were also documented. Conclusion: Reducing the BT volume coverage, better indications for surgery, and more efficient chemotherapy, all combined within a multidisciplinary approach, tended to improve results in terms of both survival and long-term sequelae.« less

  2. Experimental verification of Advanced Collapsed-cone Engine for use with a multichannel vaginal cylinder applicator.

    PubMed

    Cawston-Grant, Brie; Morrison, Hali; Menon, Geetha; Sloboda, Ron S

    2017-05-01

    Model-based dose calculation algorithms have recently been incorporated into brachytherapy treatment planning systems, and their introduction requires critical evaluation before clinical implementation. Here, we present an experimental evaluation of Oncentra ® Brachy Advanced Collapsed-cone Engine (ACE) for a multichannel vaginal cylinder (MCVC) applicator using radiochromic film. A uniform dose of 500 cGy was specified to the surface of the MCVC using the TG-43 dose formalism under two conditions: (a) with only the central channel loaded or (b) only the peripheral channels loaded. Film measurements were made at the applicator surface and compared to the doses calculated using TG-43, standard accuracy ACE (sACE), and high accuracy ACE (hACE). When the central channel of the applicator was used, the film measurements showed a dose increase of (11 ± 8)% (k = 2) above the two outer grooves on the applicator surface. This increase in dose was confirmed with the hACE calculations, but was not confirmed with the sACE calculations at the applicator surface. When the peripheral channels were used, a periodic azimuthal variation in measured dose was observed around the applicator. The sACE and hACE calculations confirmed this variation and agreed within 1% of each other at the applicator surface. Additionally for the film measurements with the central channel used, a baseline dose variation of (10 ± 4)% (k = 2) of the mean dose was observed azimuthally around the applicator surface, which can be explained by offset source positioning in the central channel. © 2017 The Authors. Journal of Applied Clinical Medical Physics published by Wiley Periodicals, Inc. on behalf of American Association of Physicists in Medicine.

  3. Manifestation Pattern of Early-Late Vaginal Morbidity After Definitive Radiation (Chemo)Therapy and Image-Guided Adaptive Brachytherapy for Locally Advanced Cervical Cancer: An Analysis From the EMBRACE Study

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Kirchheiner, Kathrin, E-mail: kathrin.kirchheiner@meduniwien.ac.at; Christian Doppler Laboratory for Medical Radiation Research for Radiation Oncology, Medical University of Vienna; Nout, Remi A.

    2014-05-01

    Background and Purpose: Brachytherapy in the treatment of locally advanced cervical cancer has changed substantially because of the introduction of combined intracavitary/interstitial applicators and an adaptive target concept, which is the focus of the prospective, multi-institutional EMBRACE study ( (www.embracestudy.dk)) on image-guided adaptive brachytherapy (IGABT). So far, little has been reported about the development of early to late vaginal morbidity in the frame of IGABT. Therefore, the aim of the present EMBRACE analysis was to evaluate the manifestation pattern of vaginal morbidity during the first 2 years of follow-up. Methods and Materials: In total, 588 patients with a median follow-up timemore » of 15 months and information on vaginal morbidity were included. Morbidity was prospectively assessed at baseline, every 3 months during the first year, and every 6 months in the second year according to the Common Terminology Criteria for Adverse Events, version 3, regarding vaginal stenosis, dryness, mucositis, bleeding, fistula, and other symptoms. Crude incidence rates, actuarial probabilities, and prevalence rates were analyzed. Results: At 2 years, the actuarial probability of severe vaginal morbidity (grade ≥3) was 3.6%. However, mild and moderate vaginal symptoms were still pronounced (grade ≥1, 89%; grade ≥2, 29%), of which the majority developed within 6 months. Stenosis was most frequently observed, followed by vaginal dryness. Vaginal bleeding and mucositis were mainly mild and infrequently reported. Conclusion: Severe vaginal morbidity within the first 2 years after definitive radiation (chemo)therapy including IGABT with intracavitary/interstitial techniques for locally advanced cervical cancer is limited and is significantly less than has been reported from earlier studies. Thus, the new adaptive target concept seems to be a safe treatment with regard to the vagina being an organ at risk. However, mild to moderate vaginal

  4. SU-E-T-759: To Replan Or Not To Replan for Each Fraction Using Inverse Optimization for Multichannel Vaginal Cylinder

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Balik, M; Rybak, M; Strongosky, M

    2015-06-15

    Purpose: This study investigates whether replanning each fraction for vaginal cuff HDR therapy using a multichannel cylinder (MC) and brachytherapy inverse optimization (BIO) provides dosimetric benefits to organs-at-risk (OAR). The goal was to appropriately cover the target and limit dose to OAR, as well as evaluate dosimetric changes for each fraction, while doing this in a timely and cost effective manner. Methods: From an initial selection of 57 patients that were treated with 3 fractions using a MC and BIO, a subset of n=12 patients was selected based on the criterion that one plan was used for all 3 fractions.more » A simulation CT was acquired prior to each fraction. CT scans for fractions 2 and 3 were fused to the initial CT. Contours for the bladder and rectum were manually drawn on CTs for all 3 fractions, and the clinical treatment volume (PTVeval) was defined. Cylinders were reconstructed using applicator modeling library, influencing time and cost effectiveness. Planning objectives were at least 95% prescription dose to 95% (D95%) of target volume and limiting high dose to OAR. Dose to 2 cm{sup 3} (D2cc) for each OAR was analyzed using a t-test. Results: This study concentrated on comparing 2cm{sup 3} of highest dose to OAR (D2cc), for each fraction for the plans that were used to treat all 3 fraction. Based on statistical analysis, using the initial plan for fractions 2 and 3 resulted in approximately 6% change to the highest D2cc of the bladder (p=0.03). Conclusion: Performing CT fusion and contours of each OAR on each fraction allows objective plan evaluation and supports decision making on the necessity of replanning based on improved dose sparing for OAR. Future studies will investigate the effects of replanning on maximum dose (D0.1cc) using the same physician-drawn OAR contours to avoid subjectivity.« less

  5. Dose Reduction Study in Vaginal Balloon Packing Filled With Contrast for HDR Brachytherapy Treatment;HDR; Uterine cervix cancer; Vaginal balloon packing; Contrast; Monte Carlo

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Saini, Amarjit S.; Zhang, Geoffrey G., E-mail: geoffrey.zhang@moffitt.org; Finkelstein, Steven E.

    2011-07-15

    Purpose: Vaginal balloon packing is a means to displace organs at risk during high dose rate brachytherapy of the uterine cervix. We tested the hypothesis that contrast-filled vaginal balloon packing reduces radiation dose to organs at risk, such as the bladder and rectum, in comparison to water- or air-filled balloons. Methods and Materials: In a phantom study, semispherical vaginal packing balloons were filled with air, saline solution, and contrast agents. A high dose rate iridium-192 source was placed on the anterior surface of the balloon, and the diode detector was placed on the posterior surface. Dose ratios were taken withmore » each material in the balloon. Monte Carlo (MC) simulations, by use of the MC computer program DOSXYZnrc, were performed to study dose reduction vs. balloon size and contrast material, including commercially available iodine- and gadolinium-based contrast agents. Results: Measured dose ratios on the phantom with the balloon radius of 3.4 cm were 0.922 {+-} 0.002 for contrast/saline solution and 0.808 {+-} 0.001 for contrast/air. The corresponding ratios by MC simulations were 0.895 {+-} 0.010 and 0.781 {+-} 0.010. The iodine concentration in the contrast was 23.3% by weight. The dose reduction of contrast-filled balloon ranges from 6% to 15% compared with water-filled balloon and 11% to 26% compared with air-filled balloon, with a balloon size range between 1.4 and 3.8 cm, and iodine concentration in contrast of 24.9%. The dose reduction was proportional to the contrast agent concentration. The gadolinium-based contrast agents showed less dose reduction because of much lower concentrations in their solutions. Conclusions: The dose to the posterior wall of the bladder and the anterior wall of the rectum can be reduced if the vaginal balloon is filled with contrast agent in comparison to vaginal balloons filled with saline solution or air.« less

  6. MR- versus CT-based high-dose-rate interstitial brachytherapy for vaginal recurrence of endometrial cancer.

    PubMed

    Kamran, Sophia C; Manuel, Matthias M; Catalano, Paul; Cho, Linda; Damato, Antonio L; Lee, Larissa J; Schmidt, Ehud J; Viswanathan, Akila N

    To compare clinical outcomes of MR-based versus CT-based high-dose-rate interstitial brachytherapy (ISBT) for vaginal recurrence of endometrioid endometrial cancer (EC). We reviewed 66 patients with vaginal recurrent EC; 18 had MR-based ISBT on a prospective clinical trial and 48 had CT-based treatment. Kaplan-Meier survival modeling was used to generate estimates for local control (LC), disease-free interval (DFI), and overall survival (OS), and multivariate Cox modeling was used to assess prognostic factors. Toxicities were evaluated and compared. Median followup was 33 months (CT 30 months, MR 35 months). Median cumulative equivalent dose in 2-Gy fractions was 75.5 Gy for MR-ISBT and 73.8 Gy for CT-ISBT (p = 0.58). MR patients were older (p = 0.03) and had larger tumor size (>4 cm vs. ≤ 4 cm) compared to CT patients (p = 0.04). For MR-based versus CT-based ISBT, 3-year KM rate for local control was 100% versus 78% (p = 0.04), DFI was 69% versus 55% (p = 0.1), and OS was 63% versus 75% (p = 0.81), respectively. On multivariate analysis, tumor Grade 3 was associated with worse OS (HR 3.57, 95% CI 1.25, 11.36) in a model with MR-ISBT (HR 0.56, 95% CI 0.16, 1.89). Toxicities were not significantly different between the two modalities. Despite worse patient prognostic features, MR-ISBT was associated with a significantly better (100%) 3-year local control, comparable survival, and improved DFI rates compared to CT. Toxicities did not differ compared to CT-ISBT patients. Tumor grade contributed as the most significant predictor for survival. Larger prospective studies are needed to assess the impact of MR-ISBT on survival outcomes. Copyright © 2017 American Brachytherapy Society. Published by Elsevier Inc. All rights reserved.

  7. SU-E-T-795: Validations of Dose Calculation Accuracy of Acuros BV in High-Dose-Rate (HDR) Brachytherapy with a Shielded Cylinder Applicator Using Monte Carlo Simulation

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Li, Y; Department of Engineering Physics, Tsinghua University, Beijing; Tian, Z

    Purpose: Acuros BV has become available to perform accurate dose calculations in high-dose-rate (HDR) brachytherapy with phantom heterogeneity considered by solving the Boltzmann transport equation. In this work, we performed validation studies regarding the dose calculation accuracy of Acuros BV in cases with a shielded cylinder applicator using Monte Carlo (MC) simulations. Methods: Fifteen cases were considered in our studies, covering five different diameters of the applicator and three different shielding degrees. For each case, a digital phantom was created in Varian BrachyVision with the cylinder applicator inserted in the middle of a large water phantom. A treatment plan withmore » eight dwell positions was generated for these fifteen cases. Dose calculations were performed with Acuros BV. We then generated a voxelized phantom of the same geometry, and the materials were modeled according to the vendor’s specifications. MC dose calculations were then performed using our in-house developed fast MC dose engine for HDR brachytherapy (gBMC) on a GPU platform, which is able to simulate both photon transport and electron transport in a voxelized geometry. A phase-space file for the Ir-192 HDR source was used as a source model for MC simulations. Results: Satisfactory agreements between the dose distributions calculated by Acuros BV and those calculated by gBMC were observed in all cases. Quantitatively, we computed point-wise dose difference within the region that receives a dose higher than 10% of the reference dose, defined to be the dose at 5mm outward away from the applicator surface. The mean dose difference was ∼0.45%–0.51% and the 95-percentile maximum difference was ∼1.24%–1.47%. Conclusion: Acuros BV is able to accurately perform dose calculations in HDR brachytherapy with a shielded cylinder applicator.« less

  8. Uncertainties in Assesment of the Vaginal Dose for Intracavitary Brachytherapy of Cervical Cancer using a Tandem-ring Applicator

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Berger, Daniel; Dimopoulos, Johannes; Georg, Petra

    2007-04-01

    Purpose: The vagina has not been widely recognized as organ at risk in brachytherapy for cervical cancer. No widely accepted dose parameters are available. This study analyzes the uncertainties in dose reporting for the vaginal wall using tandem-ring applicators. Methods and Materials: Organ wall contours were delineated on axial magnetic resonance (MR) slices to perform dose-volume histogram (DVH) analysis. Different DVH parameters were used in a feasibility study based on 40 magnetic resonance imaging (MRI)-based treatment plans of different cervical cancer patients. Dose to the most irradiated, 0.1 cm{sup 3}, 1 cm{sup 3}, 2 cm{sup 3}, and at defined pointsmore » on the ring surface and at 5-mm tissue depth were reported. Treatment-planning systems allow different methods of dose point definition. Film dosimetry was used to verify the maximum dose at the surface of the ring applicator in an experimental setup. Results: Dose reporting for the vagina is extremely sensitive to geometrical uncertainties with variations of 25% for 1 mm shifts. Accurate delineation of the vaginal wall is limited by the finite pixel size of MRI and available treatment-planning systems. No significant correlation was found between dose-point and dose-volume parameters. The DVH parameters were often related to noncontiguous volumes and were not able to detect very different situations of spatial dose distributions inside the vaginal wall. Deviations between measured and calculated doses were up to 21%. Conclusions: Reporting either point dose values or DVH parameters for the vaginal wall is based on high inaccuracies because of contouring and geometric positioning. Therefore, the use of prospective dose constraints for individual treatment plans is not to be recommended at present. However, for large patient groups treated within one protocol correlation with vaginal morbidity can be evaluated.« less

  9. Suitability of point kernel dose calculation techniques in brachytherapy treatment planning

    PubMed Central

    Lakshminarayanan, Thilagam; Subbaiah, K. V.; Thayalan, K.; Kannan, S. E.

    2010-01-01

    Brachytherapy treatment planning system (TPS) is necessary to estimate the dose to target volume and organ at risk (OAR). TPS is always recommended to account for the effect of tissue, applicator and shielding material heterogeneities exist in applicators. However, most brachytherapy TPS software packages estimate the absorbed dose at a point, taking care of only the contributions of individual sources and the source distribution, neglecting the dose perturbations arising from the applicator design and construction. There are some degrees of uncertainties in dose rate estimations under realistic clinical conditions. In this regard, an attempt is made to explore the suitability of point kernels for brachytherapy dose rate calculations and develop new interactive brachytherapy package, named as BrachyTPS, to suit the clinical conditions. BrachyTPS is an interactive point kernel code package developed to perform independent dose rate calculations by taking into account the effect of these heterogeneities, using two regions build up factors, proposed by Kalos. The primary aim of this study is to validate the developed point kernel code package integrated with treatment planning computational systems against the Monte Carlo (MC) results. In the present work, three brachytherapy applicators commonly used in the treatment of uterine cervical carcinoma, namely (i) Board of Radiation Isotope and Technology (BRIT) low dose rate (LDR) applicator and (ii) Fletcher Green type LDR applicator (iii) Fletcher Williamson high dose rate (HDR) applicator, are studied to test the accuracy of the software. Dose rates computed using the developed code are compared with the relevant results of the MC simulations. Further, attempts are also made to study the dose rate distribution around the commercially available shielded vaginal applicator set (Nucletron). The percentage deviations of BrachyTPS computed dose rate values from the MC results are observed to be within plus/minus 5.5% for

  10. Treatment of Locally Advanced Vaginal Cancer With Radiochemotherapy and Magnetic Resonance Image-Guided Adaptive Brachytherapy: Dose-Volume Parameters and First Clinical Results

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Dimopoulos, Johannes C.A.; Schmid, Maximilian P., E-mail: maximilian.schmid@akhwien.at; Fidarova, Elena

    2012-04-01

    Purpose: To investigate the clinical feasibility of magnetic resonance image-guided adaptive brachytherapy (IGABT) for patients with locally advanced vaginal cancer and to report treatment outcomes. Methods and Materials: Thirteen patients with vaginal cancer were treated with external beam radiotherapy (45-50.4 Gy) plus IGABT with or without chemotherapy. Distribution of International Federation of Gynecology and Obstetrics stages among patients were as follows: 4 patients had Stage II cancer, 5 patients had Stage III cancer, and 4 patients had Stage IV cancer. The concept of IGABT as developed for cervix cancer was transferred and adapted for vaginal cancer, with corresponding treatment planningmore » and reporting. Doses were converted to the equivalent dose in 2 Gy, applying the linear quadratic model ({alpha}/{beta} = 10 Gy for tumor; {alpha}/{beta} = 3 for organs at risk). Endpoints studied were gross tumor volume (GTV), dose-volume parameters for high-risk clinical target volume (HRCTV), and organs at risk, local control (LC), adverse side effects, and survival. Results: The mean GTV ({+-} 1 standard deviation) at diagnosis was 45.3 ({+-}30) cm{sup 3}, and the mean GTV at brachytherapy was 10 ({+-}14) cm{sup 3}. The mean D90 for the HRCTV was 86 ({+-}13) Gy. The mean D2cc for bladder, urethra, rectum, and sigmoid colon were 80 ({+-}20) Gy, 76 ({+-}16) Gy, 70 ({+-}9) Gy, and 60 ({+-}9) Gy, respectively. After a median follow-up of 43 months (range, 19-87 months), one local recurrence and two distant metastases cases were observed. Actuarial LC and overall survival rates at 3 years were 92% and 85%. One patient with Stage IVA and 1 patient with Stage III disease experienced fistulas (one vesicovaginal, one rectovaginal), and 1 patient developed periurethral necrosis. Conclusions: The concept of IGABT, originally developed for treating cervix cancer, appears to be applicable to vaginal cancer treatment with only minor adaptations. Dose-volume parameters for

  11. SU-F-P-61: Does It Matter Not to Use Optimization Points at the Apex for Vaginal Cylinder HDR Brachytherapy Planning?

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Kim, Y

    2016-06-15

    Purpose: To test the impact of the use of apex optimization points for new vaginal cylinder (VC) applicators. Methods: New “ClickFit” single channel VC applicators (Varian) that have a different top thicknesses but the same diameters as the old VC applicators (2.3 cm diameter, 2.6 cm, 3.0 cm, and 3.5 cm) were compared using phantom studies. Old VC applicator plans without apex optimization points were also compared to the plans with the optimization points. The apex doses were monitored at 5 mm depth doses (8 points) where a prescription dose (Rx) of 6Gy was prescribed. VC surface doses (8 points)more » were also analyzed. Results: The new VC applicator plans without apex optimization points presented significantly lower 5mm depth doses than Rx (on average −31 ± 7%, p <0.00001) due to their thicker VC tops (3.4 ± 1.1 mm thicker with the range of 1.2 to 4.4 mm) than the old VC applicators. Old VC applicator plans also showed a statistically significant reduction (p <0.00001) due to Ir-192 source anisotropic effect at the apex region but the % reduction over Rx was only −7 ± 9%. However, by adding apex optimization points to the new VC applicator plans, the plans improved 5 mm depth doses (−7 ± 9% over Rx) that were not statistically different from old VC plans (p = 0.923), along with apex VC surface doses (−22 ± 10% over old VC versus −46 ± 7% without using apex optimization points). Conclusion: The use of apex optimization points are important in order to avoid significant additional cold doses (−24 ± 2%) at the prescription depth (5 mm) of apex, especially for the new VC applicators that have thicker tops.« less

  12. Impact of the vaginal applicator and dummy pellets on the dosimetry parameters of Cs-137 brachytherapy source.

    PubMed

    Sina, Sedigheh; Faghihi, Reza; Meigooni, Ali S; Mehdizadeh, Simin; Mosleh Shirazi, M Amin; Zehtabian, Mehdi

    2011-05-19

    In this study, dose rate distribution around a spherical 137Cs pellet source, from a low-dose-rate (LDR) Selectron remote afterloading system used in gynecological brachytherapy, has been determined using experimental and Monte Carlo simulation techniques. Monte Carlo simulations were performed using MCNP4C code, for a single pellet source in water medium and Plexiglas, and measurements were performed in Plexiglas phantom material using LiF TLD chips. Absolute dose rate distribution and the dosimetric parameters, such as dose rate constant, radial dose functions, and anisotropy functions, were obtained for a single pellet source. In order to investigate the effect of the applicator and surrounding pellets on dosimetric parameters of the source, the simulations were repeated for six different arrangements with a single active source and five non-active pellets inside central metallic tubing of a vaginal cylindrical applicator. In commercial treatment planning systems (TPS), the attenuation effects of the applicator and inactive spacers on total dose are neglected. The results indicate that this effect could lead to overestimation of the calculated F(r,θ), by up to 7% along the longitudinal axis of the applicator, especially beyond the applicator tip. According to the results obtained in this study, in a real situation in treatment of patients using cylindrical vaginal applicator and using several active pellets, there will be a large discrepancy between the result of superposition and Monte Carlo simulations.

  13. A dosimetric analysis of intensity-modulated radiation therapy (IMRT) as an alternative to adjuvant high-dose-rate (HDR) brachytherapy in early endometrial cancer patients

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Aydogan, Bulent; Mundt, Arno J.; Department of Radiation Oncology, University of Illinois at Chicago, Chicago, IL

    2006-05-01

    Purpose: To evaluate the role of intensity-modulated radiation treatment (IMRT) as an alternative to high-dose-rate (HDR) brachytherapy in the treatment of the vagina in postoperative early endometrial cancer patients after surgery. Methods and Materials: Planning computed tomography (CT) scans of 10 patients previously treated with HDR were used in this study. In all cases, a dose of 700 cGy/fraction was prescribed at a distance of 0.5 cm from the cylinder surface. The same CT scans were then used in IMRT planning. In this paradigm, the vaginal cylinder represents a component of a hypothetical immobilization system that would be indexed tomore » the linac treatment table. Results: Our study showed that IMRT provided relatively lower rectal doses than HDR when treatment was prescribed at a distance of 0.5 cm away from the cylinder surface. Maximum rectal doses were lower with IMRT compared with HDR (average: 89.0% vs. 142.6%, respectively, p < 0.05). Moreover, the mean rectal dose was lower in IMRT plans compared with HDR plans with treatment prescribed either to the surface (average: 14.8% vs. 21.4%, respectively, p < 0.05) or to 0.5 cm (average: 19.6% vs. 33.5%, respectively, p < 0.05). IMRT plans had planning target volume (PTV) coverage comparable with HDR (average PTV minimum for treatment prescribed to 0.5 cm: 93.9% vs. 92.1%, p = 0.71, respectively) with less inhomogeneity (average PTV maximum: 110.8% vs. 381.6%, p < 0.05). Conclusion: Our dosimetric analysis suggests that when used in conjunction with a suitable immobilization system, IMRT may provide an alternative to HDR brachytherapy in women with early endometrial cancer after hysterectomy. However, more studies are needed to evaluate the clinical merit of the IMRT in these patients.« less

  14. SU-F-T-26: A Study of the Consistency of Brachytherapy Treatments for Vaginal Cuff

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Shojaei, M; Pella, S; Dumitru, N

    2016-06-15

    Purpose: To evaluate to treatment consistency over the total number of fractions when treatment what HDR brachytherapy using the ML cylinders. At the same time the dosimetric impact on the critical organs is monitored over the total number of fractions. Methods: A retrospective analysis of 10 patients treated with Cylinder applicators, from 2015–2016 were considered for this study. The CT scans of these patients, taken before each treatment were separately imported in to the treatment planning system and paired with the initial CT scan after completing the contouring. Two sets of CT images were fused together with respective to themore » applicator, using landmark registration. The doses of each plan were imported as well and a cumulative dosimetric analysis was made for bladder, bowels, and rectum and PTV. Results: No contour of any of the OAR was exactly similar when CT images were fused on each other. The PTV volumes vary from fraction to fraction. There was always a difference between the doses received by the OARs between treatments. The maximum dose varied between 5% and 30% in rectum and bladder. The minimum dose varied between 5% and 8% in rectum and bladder. The average dose varied between 15% and 20% in rectum and bladder. Deviation in placement were noticed between fractions. Conclusion: The variation in volumes of OARs and isodoses near the OARs, indicate that the estimated doses to OARs on the planning system may not be the same dose delivered to the patient in all the fractions. There are no major differences between the prescribed dose and the delivered dose over the total number of fractions. In some cases the critical organs will benefit if the consecutive plans will made after the CT scans will be registered with the initial scan and then planned.« less

  15. Development of 3D ultrasound needle guidance for high-dose-rate interstitial brachytherapy of gynaecological cancers

    NASA Astrophysics Data System (ADS)

    Rodgers, J.; Tessier, D.; D'Souza, D.; Leung, E.; Hajdok, G.; Fenster, A.

    2016-04-01

    High-dose-rate (HDR) interstitial brachytherapy is often included in standard-of-care for gynaecological cancers. Needles are currently inserted through a perineal template without any standard real-time imaging modality to assist needle guidance, causing physicians to rely on pre-operative imaging, clinical examination, and experience. While two-dimensional (2D) ultrasound (US) is sometimes used for real-time guidance, visualization of needle placement and depth is difficult and subject to variability and inaccuracy in 2D images. The close proximity to critical organs, in particular the rectum and bladder, can lead to serious complications. We have developed a three-dimensional (3D) transrectal US system and are investigating its use for intra-operative visualization of needle positions used in HDR gynaecological brachytherapy. As a proof-of-concept, four patients were imaged with post-insertion 3D US and x-ray CT. Using software developed in our laboratory, manual rigid registration of the two modalities was performed based on the perineal template's vaginal cylinder. The needle tip and a second point along the needle path were identified for each needle visible in US. The difference between modalities in the needle trajectory and needle tip position was calculated for each identified needle. For the 60 needles placed, the mean trajectory difference was 3.23 +/- 1.65° across the 53 visible needle paths and the mean difference in needle tip position was 3.89 +/- 1.92 mm across the 48 visible needles tips. Based on the preliminary results, 3D transrectal US shows potential for the development of a 3D US-based needle guidance system for interstitial gynaecological brachytherapy.

  16. SU-E-T-758: To Determine the Source Dwell Positions of HDR Brachytherapy Using 2D 729 Ion Chamber Array

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Kumar, Syam; Sitha

    2015-06-15

    Purpose: Determination of source dwell positions of HDR brachytherapy using 2D 729 ion chamber array Methods: Nucletron microselectron HDR and PTW 2D array were used for the study. Different dwell positions were assigned in the HDR machine. Rigid interstitial needles and vaginal applicator were positioned on the 2D array. The 2D array was exposed for this programmed dwell positions. The positional accuracy of the source was analyzed after the irradiation of the 2D array. This was repeated for different dwell positions. Different test plans were transferred from the Oncentra planning system and irradiated with the same applicator position on themore » 2D array. The results were analyzed using the in house developed excel program. Results: Assigned dwell positions versus corresponding detector response were analyzed. The results show very good agreement with the film measurements. No significant variation found between the planned and measured dwell positions. Average dose response with 2D array between the planned and nearby dwell positions was found to be 0.0804 Gy for vaginal cylinder applicator and 0.1234 Gy for interstitial rigid needles. Standard deviation between the doses for all the measured dwell positions for interstitial rigid needle for 1 cm spaced positions were found to be 0.33 and 0.37 for 2cm spaced dwell positions. For intracavitory vaginal applicator this was found to be 0.21 for 1 cm spaced dwell positions and 0.06 for 2cm spaced dwell positions. Intracavitory test plans reproduced on the 2D array with the same applicator positions shows the ideal dose distribution with the TPS planned. Conclusion: 2D array is a good tool for determining the dwell position of HDR brachytherapy. With the in-house developed program in excel it is easy and accurate. The traditional way with film analysis can be replaced by this method, as the films will be more costly.« less

  17. WE-F-16A-01: Commissioning and Clinical Use of PC-ISO for Customized, 3D Printed, Gynecological Brachytherapy Applicators

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Cunha, J; Sethi, R; Mellis, K

    Purpose: (1) Evaluate the safety and radiation attenuation properties of PCISO, a bio-compatible, sterilizable 3D printing material by Stratasys, (2) establish a method for commissioning customized multi- and single-use 3D printed applicators, (3) report on use of customized vaginal cylinders used to treat a series of serous endometrial cancer patient. Methods: A custom film dosimetry apparatus was designed to hold a Gafchromic radio film segment between two blocks of PC-ISO and 3D-printed using a Fortus 400mc (StrataSys). A dose plan was computed using 13 dwell positions at 2.5 mm spacing and normalized to 1500 cGy at 1 cm. Film exposuremore » was compared to control tests in only air and only water. The average Hounsfield Unit (HU) was computed and used to verify water equivalency. For the clinical use cases, the physician specifies the dimensions and geometry of a custom applicator from which a CAD model is designed and printed. Results: The doses measured from the PC-ISO Gafchromic film test were within 1% of the dose measured in only water between 1cm and 6cm from the channel. Doses increased 7–4% measured in only air. HU range was 11–43. The applicators were sterilized using the Sterrad system multiple times without damage. As of submission 3 unique cylinders have been designed, printed, and used in the clinic. A standardizable workflow for commissioning custom 3D printed applicators was codified and will be reported. Conclusions: Quality assurance (QA) evaluation of the PC-ISO 3D-printing material showed that PC-ISO is a suitable material for a gynecological brachytherapy vaginal cylinder in a clinical setting. With the material commissioning completed, if the physician determines that a better treatment would Result, a customized design is fabricated with limited additional QA necessary. Although this study was specific to PC-ISO, the same setup can be used to evaluate other 3D-printing materials.« less

  18. Administration of Concurrent Vaginal Brachytherapy During Chemotherapy for Treatment of Endometrial Cancer

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Nagar, Himanshu; Boothe, Dustin; Parikh, Amar

    2013-11-15

    Purpose: To evaluate the tolerability and toxicity of administering vaginal brachytherapy (VB) concurrently during chemotherapy compared with the sequential approach for patients with endometrial cancer. Methods and Materials: A retrospective analysis of 372 surgically staged patients with endometrial cancer American Joint Committee on Cancer 2009 stages I to IV treated with adjuvant postoperative radiation therapy (RT) at our institution from 2001 to 2012 was conducted. All patients received VB + external beam RT (EBRT) + 6 cycles of adjuvant carboplatin- and paclitaxel-based chemotherapy. The VB mean dose was 15.08 Gy (range, 15-20 Gy), with 3 to 4 weekly applications, andmore » the EBRT mean dose was 45 Gy delivered with 3-dimensional or intensity modulated RT techniques. Hematologic, gastrointestinal (GI), and genitourinary (GU) toxicities were assessed by Common Toxicity Criteria (CTC) and compared between sequential and concurrent chemotherapy and VB schedules. Results: Among patients who received RT and adjuvant chemotherapy, 180 of 372 patients (48%) received RT sandwiched between cycles 3 and 4 of chemotherapy. A separate group of 192 patients (52%) were treated with VB during the first 3 cycles of chemotherapy, with a weekly application on nonchemotherapy days, and received the EBRT portion in a sandwiched fashion. Patients treated with VB during chemotherapy had a decreased overall treatment time by 4 weeks (P<.001; 95% confidence interval: 3.99-4.02) and sustained no difference in CTC-graded acute hematologic, GI, or GU toxicities in comparison with the patients treated with VB and chemotherapy in a sequential manner (P>.05). CTC grade 3 or 4 hematologic, GI, and GU toxicities were zero. Conclusions: VB during chemotherapy is well tolerated, decreases overall treatment time, and does not render more toxicity than the sequential regimen.« less

  19. Study of two different radioactive sources for prostate brachytherapy treatment

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Pereira Neves, Lucio; Perini, Ana Paula; Souza Santos, William de

    In this study we evaluated two radioactive sources for brachytherapy treatments. Our main goal was to quantify the absorbed doses on organs and tissues of an adult male patient, submitted to a brachytherapy treatment with two radioactive sources. We evaluated a {sup 192}Ir and a {sup 125}I radioactive sources. The {sup 192}Ir radioactive source is a cylinder with 0.09 cm in diameter and 0.415 cm long. The {sup 125}I radioactive source is also a cylinder, with 0.08 cm in diameter and 0.45 cm long. To evaluate the absorbed dose distribution on the prostate, and other organs and tissues of anmore » adult man, a male virtual anthropomorphic phantom MASH, coupled in the radiation transport code MCNPX 2.7.0, was employed.We simulated 75, 90 and 102 radioactive sources of {sup 125}I and one of {sup 192}Ir, inside the prostate, as normally used in these treatments, and each treatment was simulated separately. As this phantom was developed in a supine position, the displacement of the internal organs of the chest, compression of the lungs and reduction of the sagittal diameter were all taken into account. For the {sup 192}Ir, the higher doses values were obtained for the prostate and surrounding organs, as the colon, gonads and bladder. Considering the {sup 125}I sources, with photons with lower energies, the doses to organs that are far from the prostate were lower. All values for the dose rates are in agreement with those recommended for brachytherapy treatments. Besides that, the new seeds evaluated in this work present usefulness as a new tool in prostate brachytherapy treatments, and the methodology employed in this work may be applied for other radiation sources, or treatments. (authors)« less

  20. Clinical Outcomes in International Federation of Gynecology and Obstetrics Stage IA Endometrial Cancer With Myometrial Invasion Treated With or Without Postoperative Vaginal Brachytherapy

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Diavolitsis, V.; Rademaker, A.; Lurain, J.

    2012-10-01

    Purpose: To assess the clinical outcomes of patients with Stage IA endometrial cancer with myometrial invasion treated with postoperative vaginal brachytherapy (VBT) with those who received no adjuvant therapy (NAT). Methods and Materials: All patients treated with hysterectomy for endometrial cancer at Northwestern Memorial Hospital between 1978 and 2005 were identified. Those patients with Stage IA disease with myometrial invasion who were treated with VBT alone or NAT were identified and included in the present analysis. Results: Of 252 patients with Stage IA endometrial cancer with superficial (<50%) myometrial invasion who met the inclusion criteria, 169 underwent VBT and 83more » received NAT. The median follow-up in the VBT and NAT groups was 103 and 61 months, respectively. In the VBT group, 56.8% had Grade 1, 37.9% had Grade 2, and 5.3% had Grade 3 tumors. In the NAT group, 75.9%, 20.5%, and 3.6% had Grade 1, 2, and 3 tumors, respectively. Lymphatic or vascular space invasion was noted in 12.4% of the VBT patients and 5.6% of the NAT patients. The 5-year overall survival rate was 95.5%. The 5-year recurrence-free survival rate was 92.4% for all patients, 94.4% for the VBT group, and 87.4% for the NAT group (p = NS). Of the 169 VBT patients and 83 NAT patients, 8 (4.7%) and 6 (7.2%) developed recurrent disease. One vaginal recurrence occurred in the VBT group (0.6%) and three in the NAT group (3.8%). Recurrences developed 2-102 months after surgical treatment. Two of the four vaginal recurrences were salvaged. No Grade 3 or higher acute or late radiation toxicity was noted. Conclusions: The use of postoperative VBT in patients with Stage I endometrial cancer with <50% myometrial invasion yielded excellent vaginal disease control and disease-free survival, with minimal toxicity.« less

  1. Radiation-induced vaginal stenosis: current perspectives

    PubMed Central

    Morris, Lucinda; Do, Viet; Chard, Jennifer; Brand, Alison H

    2017-01-01

    Treatment of gynecological cancer commonly involves pelvic radiation therapy (RT) and/or brachytherapy. A commonly observed side effect of such treatment is radiation-induced vaginal stenosis (VS). This review analyzed the incidence, pathogenesis, clinical manifestation(s) and assessment and grading of radiation-induced VS. In addition, risk factors, prevention and treatment options and follow-up schedules are also discussed. The limited available literature on many of these aspects suggests that additional studies are required to more precisely determine the best management strategy of this prevalent group after RT. PMID:28496367

  2. Single line source with and without vaginal loading and the impact on target coverage and organ at risk doses for cervix cancer Stages IB, II, and IIIB: treatment planning simulation in patients treated with MRI-guided adaptive brachytherapy in a multicentre study (EMBRACE).

    PubMed

    Nkiwane, Karen S; Pötter, Richard; Tanderup, Kari; Federico, Mario; Lindegaard, Jacob C; Kirisits, Christian

    2013-01-01

    Three-dimensional evaluation and comparison of target and organs at risk (OARs) doses from two traditional standard source loading patterns in the frame of MRI-guided cervical cancer brachytherapy for various clinical scenarios based on patient data collected in a multicenter trial setting. Two nonoptimized three-dimensional MRI-based treatment plans, Plan 1 (tandem and vaginal loading) and Plan 2 (tandem loading only), were generated for 134 patients from seven centers participating in the EMBRACE study. Both plans were normalized to point A (Pt. A). Target and OAR doses were evaluated in terms of minimum dose to 90% of the high-risk clinical target volume (HRCTV D90) grouped by tumor stage and minimum dose to the most exposed 2cm³ of the OARs volume. An HRCTV D90 ≥ Pt. A was achieved in 82% and 44% of the patients with Plans 1 and 2, respectively. Median HRCTV D90 with Plans 1 and 2 was 120% and 90% of Pt. A dose, respectively. Both plans had optimal dose coverage in 88% of Stage IB tumors; however, the tandem-only plan resulted in about 50% of dose reduction to the vagina and rectum. For Stages IIB and IIIB, Plan 1 had on average 35% better target coverage but with significant doses to OARs. Standard tandem loading alone results in good target coverage in most Stage IB tumors without violating OAR dose constraints. For Stage IIB tumors, standard vaginal loading improves the therapeutic window, however needs optimization to fulfill the dose prescription for target and OAR. In Stage IIIB, even optimized vaginal loading often does not fulfill the needs for dose prescription. The significant dose variation across various clinical scenarios for both target and OARs indicates the need for image-guided brachytherapy for optimal dose adaptation both for limited and advanced diseases. Copyright © 2013 American Brachytherapy Society. Published by Elsevier Inc. All rights reserved.

  3. Vaginal vault dehiscence after robotic hysterectomy for gynecologic cancers: search for risk factors and literature review.

    PubMed

    Drudi, Laura; Press, Joshua Z; Lau, Susie; Gotlieb, Raphael; How, Jeffrey; Eniu, Ioana; Drummond, Nancy; Brin, Sonya; Deland, Claire; Gotlieb, Walter H

    2013-06-01

    Vaginal vault dehiscence following robotic-assisted hysterectomy for gynecologic cancer may be attributed to surgical techniques and postoperative therapeutic interventions. We searched for risk factors in patients with gynecologic cancers and complemented this with a literature review. Evaluation of prospectively gathered information on all consecutive robotic surgeries for gynecologic cancers was performed in a tertiary academic cancer center between December 2007 and March 2012. The literature was reviewed for articles relevant to "gynecologic oncology" and "robotics" with "vaginal cuff dehiscence" in the English and French languages. Respective authors were contacted to complete relevant information. Seven dehiscences were identified of 441 cases with established gynecologic cancers. The closures in these 7 were performed using interrupted 1-Vicryl (Ethicon Inc) (3/167; 1.8%), combination of interrupted 1-Vicryl and 1-Biosyn (Covidien Inc) (3/156, 1.9%), and V-Loc (Covidien Inc) (1/118, 0.8%) sutures. Associated risk factors included adjuvant chemotherapy and/or brachytherapy, early resumption of sexual activity, and low body mass index (mean, 23 ± 3.23 kg/m²). Dehiscences occurred regardless of suturing by staff or trainees. Review of operative videos did not reveal a detectable etiologic factor, such as excessive cautery damage to the vaginal cuff or shallow tissue sutured. All 7 colporrhexis repairs were performed through a vaginal approach without the need of laparoscopy or laparotomy. Postoperative chemotherapy, brachytherapy, and early resumption of sexual activities are risk factors for vaginal vault dehiscence. Surgical technique, particularly the use of delayed absorbable sutures, deserves further evaluation.

  4. EM-navigated catheter placement for gynecologic brachytherapy: an accuracy study

    NASA Astrophysics Data System (ADS)

    Mehrtash, Alireza; Damato, Antonio; Pernelle, Guillaume; Barber, Lauren; Farhat, Nabgha; Viswanathan, Akila; Cormack, Robert; Kapur, Tina

    2014-03-01

    Gynecologic malignancies, including cervical, endometrial, ovarian, vaginal and vulvar cancers, cause significant mortality in women worldwide. The standard care for many primary and recurrent gynecologic cancers consists of chemoradiation followed by brachytherapy. In high dose rate (HDR) brachytherapy, intracavitary applicators and /or interstitial needles are placed directly inside the cancerous tissue so as to provide catheters to deliver high doses of radiation. Although technology for the navigation of catheters and needles is well developed for procedures such as prostate biopsy, brain biopsy, and cardiac ablation, it is notably lacking for gynecologic HDR brachytherapy. Using a benchtop study that closely mimics the clinical interstitial gynecologic brachytherapy procedure, we developed a method for evaluating the accuracy of image-guided catheter placement. Future bedside translation of this technology offers the potential benefit of maximizing tumor coverage during catheter placement while avoiding damage to the adjacent organs, for example bladder, rectum and bowel. In the study, two independent experiments were performed on a phantom model to evaluate the targeting accuracy of an electromagnetic (EM) tracking system. The procedure was carried out using a laptop computer (2.1GHz Intel Core i7 computer, 8GB RAM, Windows 7 64-bit), an EM Aurora tracking system with a 1.3mm diameter 6 DOF sensor, and 6F (2 mm) brachytherapy catheters inserted through a Syed-Neblett applicator. The 3D Slicer and PLUS open source software were used to develop the system. The mean of the targeting error was less than 2.9mm, which is comparable to the targeting errors in commercial clinical navigation systems.

  5. Combined experimental and Monte Carlo verification of brachytherapy plans for vaginal applicators

    NASA Astrophysics Data System (ADS)

    Sloboda, Ron S.; Wang, Ruqing

    1998-12-01

    Dose rates in a phantom around a shielded and an unshielded vaginal applicator containing Selectron low-dose-rate sources were determined by experiment and Monte Carlo simulation. Measurements were performed with thermoluminescent dosimeters in a white polystyrene phantom using an experimental protocol geared for precision. Calculations for the same set-up were done using a version of the EGS4 Monte Carlo code system modified for brachytherapy applications into which a new combinatorial geometry package developed by Bielajew was recently incorporated. Measured dose rates agree with Monte Carlo estimates to within 5% (1 SD) for the unshielded applicator, while highlighting some experimental uncertainties for the shielded applicator. Monte Carlo calculations were also done to determine a value for the effective transmission of the shield required for clinical treatment planning, and to estimate the dose rate in water at points in axial and sagittal planes transecting the shielded applicator. Comparison with dose rates generated by the planning system indicates that agreement is better than 5% (1 SD) at most positions. The precision thermoluminescent dosimetry protocol and modified Monte Carlo code are effective complementary tools for brachytherapy applicator dosimetry.

  6. Clinical analysis of speculum-based vaginal packing for high-dose-rate intracavitary tandem and ovoid brachytherapy in cervical cancer

    PubMed Central

    Sud, Shivani; Roth, Toni

    2018-01-01

    Purpose Intra-vaginal packing is used to fix the applicator and displace organs at risk (OAR) during high-dose-rate intracavitary tandem and ovoid brachytherapy (HDR-ICB). We retain the speculum from applicator placement as a dual-function bladder and rectum retractor during treatment. Our objective is to review salient techniques for OAR displacement, share our packing technique, and determine the reduction in dose to OAR and inter-fraction variability of dose to OAR, associated with speculum-based vaginal packing (SBVP) in comparison to conventional gauze packing during HDR-ICB. Material and methods We reviewed HDR-ICB treatment plans for 45 patients, including 10 who underwent both conventional gauze packing and SBVP. Due to institutional inter-provider practice differences, patients non-selectively received either packing procedure. Packing was performed under conscious sedation, followed by cone beam computed tomography used for dosimetric planning. Maximum absolute and percent-of-prescription dose to the International Commission of Radiation Units bladder and rectal points in addition to D0.1cc, D1.0cc, and D2.0cc volumes of the bladder and rectum were analyzed and compared for each packing method using an independent sample t-test. Results Of the 179 fractions included, 73% and 27% used SBVP and gauze packing, respectively. For patients prescribed 6 Gy to point A, SBVP was associated with reduced mean D0.1cc bladder dose, inter-fraction variability in D0.1cc bladder dose by 9.3% (p = 0.026) and 9.0%, respectively, and statistically equivalent rectal D0.1cc, D1.0cc, and D2.0cc. Patients prescribed 5.5 Gy or 5 Gy to point A after dose optimization, were less likely to benefit from SBVP. In the intra-patient comparison, 80% of patients had reduction in at least one rectum or bladder parameter. Conclusions In patients with conducive anatomy, SBVP is a cost-efficient packing method that is associated with improved bladder sparing and comparable rectal sparing

  7. Magnitude of Interfractional Vaginal Cuff Movement: Implications for External Irradiation

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Ma, Daniel J.; Michaletz-Lorenz, Martha; Goddu, S. Murty

    2012-03-15

    Purpose: To quantify the extent of interfractional vaginal cuff movement in patients receiving postoperative irradiation for cervical or endometrial cancer in the absence of bowel/bladder instruction. Methods and Materials: Eleven consecutive patients with cervical or endometrial cancer underwent placement of three gold seed fiducial markers in the vaginal cuff apex as part of standard of care before simulation. Patients subsequently underwent external irradiation and brachytherapy treatment based on institutional guidelines. Daily megavoltage CT imaging was performed during each external radiation treatment fraction. The daily positions of the vaginal apex fiducial markers were subsequently compared with the original position of themore » fiducial markers on the simulation CT. Composite dose-volume histograms were also created by summing daily target positions. Results: The average ({+-} standard deviation) vaginal cuff movement throughout daily pelvic external radiotherapy when referenced to the simulation position was 16.2 {+-} 8.3 mm. The maximum vaginal cuff movement for any patient during treatment was 34.5 mm. In the axial plane the mean vaginal cuff movement was 12.9 {+-} 6.7 mm. The maximum vaginal cuff axial movement was 30.7 mm. In the craniocaudal axis the mean movement was 10.3 {+-} 7.6 mm, with a maximum movement of 27.0 mm. Probability of cuff excursion outside of the clinical target volume steadily dropped as margin size increased (53%, 26%, 4.2%, and 1.4% for 1.0, 1.5, 2.0, and 2.5 cm, respectively.) However, rectal and bladder doses steadily increased with larger margin sizes. Conclusions: The magnitude of vaginal cuff movement is highly patient specific and can impact target coverage in patients without bowel/bladder instructions at simulation. The use of vaginal cuff fiducials can help identify patients at risk for target volume excursion.« less

  8. Cervical brachytherapy technique for locally advanced carcinoma of the cervix in a patient with septate uterus.

    PubMed

    Platta, Christopher S; Wallace, Charlie; Gondi, Vinai; Das, Rupak; Straub, Margaret; Al-Niaimi, Ahmed; Applegate, Glenn; Bradley, Kristin A

    2014-03-01

    To describe an approach to cervical brachytherapy in a patient with congenital septate uterus and locally advanced cervical carcinoma. The patient is a 34-year-old female with septate uterus presenting with pelvic pain. Workup demonstrated a stage IIB cervical adenocarcinoma with imaging evidence of an involved right external iliac lymph node. The patient received whole pelvic radiation, with concurrent weekly cisplatin (40 mg/m(2)), to a dose of 45 Gy in 25 fractions followed by a parametrial boost of 5.4 Gy and an additional nodal boost of 9 Gy. The patient was initiated on cervical brachytherapy following fraction 23 of pelvic radiation. To conform to her septated uterus, a Rotte-Y tandem was used. Additionally, 2 CT-compatible ovoids were placed in the vaginal apex to enhance dose distribution and coverage of the target volume. Each fraction of brachytherapy was performed with CT-based planning. A high-risk clinical target volume (HR-CTV) and normal structures were defined and constrained per American Brachytherapy Society (ABS) and Groupe Européen de Curiethérapie/European Society for Therapeutic Radiology and Oncology (GEC-ESTRO) guidelines. The brachytherapy dose was 27.5 Gy in 5 fractions of 5.5 Gy each, prescribed to the HR-CTV. Herein, we report the first documented case of cervical brachytherapy in a patient with septate uterus and locally advanced cervical carcinoma. Using CT-guided planning, in conjunction with the ABS and GEC-ESTRO guidelines, the patient was effectively treated with adapted cervical brachytherapy, meeting criteria for HR-CTV coverage and normal tissue tolerances.

  9. New thermal method for evaluating vaginal blood flow.

    PubMed

    Frisinger, J E; Abrams, R M; Graichen, H; Cassin, S

    1981-01-01

    The goal of this study was the development noninvasive technique for measurement of vaginal blood flow. A vaginal probe (diameter 1.84 cm; length 7.0 cm) was constructed by winding 23 m of 34-gauge enameled copper wire around a hollow cylinder of epoxy-impregnated glass wool. Resistance of the wire was 20 omega at 40 degrees C. Surface area of coil was 40.5 cm2. The temperature of the wire midway along the coil was measured continuously with a thermcouple. Temperature difference (delta T) between coil and vagina was raised by delivery of 300 mA with a resultant production of 1.8 W. In ewes treated with 1 mg estrone im., delta T fell significantly (p less than 0.025) by 90 min and (p less than 0.005) by 120 min after injection. There was a significant correlation between delta T and vaginal blood flow as measured by the radiolabeled microsphere technique.

  10. Factors associated with changes in vaginal length and diameter during pelvic radiotherapy for cervical cancer.

    PubMed

    Martins, Jumara; Vaz, Ana Francisca; Grion, Regina Celia; Esteves, Sérgio Carlos Barros; Costa-Paiva, Lúcia; Baccaro, Luiz Francisco

    2017-12-01

    This study reports the incidence and factors associated with vaginal stenosis and changes in vaginal dimensions after pelvic radiotherapy for cervical cancer. A descriptive longitudinal study with 139 women with cervical cancer was conducted from January 2013 to November 2015. The outcome variables were vaginal stenosis assessed using the Common Terminology Criteria for Adverse Events (CTCAE v3.0) and changes in vaginal diameter and length after the end of radiotherapy. Independent variables were the characteristics of the neoplasm, clinical and sociodemographic data. Bivariate analysis was carried out using χ 2 , Kruskal-Wallis and Mann-Whitney's test. Multiple analysis was carried out using Poisson regression and a generalized linear model. Most women (50.4%) had stage IIIB tumors. According to CTCAE v3.0 scale, 30.2% had no stenosis, 69.1% had grade 1 and 0.7% had grade 2 stenosis after radiotherapy. Regarding changes in vaginal measures, the mean variation in diameter was - 0.6 (± 1.7) mm and the mean variation in length was - 0.6 (± 1.3) cm. In the final statistical model, having tumoral invasion of the vaginal walls (coefficient + 0.73, p < 0.01) and diabetes (coefficient + 1.16; p < 0.01) were associated with lower vaginal stenosis and lower reduction of vaginal dimensions. Advanced clinical stage (coefficient + 1.44; p = 0.02) and receiving brachytherapy/teletherapy (coefficient - 1.17, p < 0.01) were associated with higher reduction of vaginal dimensions. Most women had mild vaginal stenosis with slight reductions in both diameter and length of the vaginal canal. Women with tumoral invasion of the vagina have an increase in vaginal length soon after radiotherapy due to a reduction in tumoral volume.

  11. Comparative dosimetric and radiobiological assessment among a nonstandard RapidArc, standard RapidArc, classical intensity-modulated radiotherapy, and 3D brachytherapy for the treatment of the vaginal vault in patients affected by gynecologic cancer

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Pedicini, Piernicola, E-mail: ppiern@libero.it; Caivano, Rocchina; Fiorentino, Alba

    2012-01-01

    To evaluate a nonstandard RapidArc (RA) modality as alternative to high-dose-rate brachytherapy (HDR-BRT) or IMRT treatments of the vaginal vault in patients with gynecological cancer (GC). Nonstandard (with vaginal applicator) and standard (without vaginal applicator) RapidArc plans for 27 women with GC were developed to compare with HDR-BRT and IMRT. Dosimetric and radiobiological comparison were performed by means of dose-volume histogram and equivalent uniform dose (EUD) for planning target volume (PTV) and organs at risk (OARs). In addition, the integral dose and the overall treatment times were evaluated. RA, as well as IMRT, results in a high uniform dose onmore » PTV compared with HDR-BRT. However, the average of EUD for HDR-BRT was significantly higher than those with RA and IMRT. With respect to the OARs, standard RA was equivalent of IMRT but inferior to HDR-BRT. Furthermore, nonstandard RA was comparable with IMRT for bladder and sigmoid and better than HDR-BRT for the rectum because of a significant reduction of d{sub 2cc}, d{sub 1cc}, and d{sub max} (p < 0.01). Integral doses were always higher than HDR-BRT, although the values were very low. Delivery times were about the same and more than double for HDR-BRT compared with IMRT and RA, respectively. In conclusion, the boost of dose on vaginal vault in patients affected by GC delivered by a nonstandard RA technique was a reasonable alternative to the conventional HDR-BRT because of a reduction of delivery time and rectal dose at substantial comparable doses for the bladder and sigmoid. However HDR-BRT provides better performance in terms of PTV coverage as evidenced by a greater EUD.« less

  12. SU-G-201-07: Dosimetric Verification of a 3D Printed HDR Skin Brachytherapy Applicator

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Rasmussen, K; Stanley, D; Eng, T

    Purpose: The use of radiation as a treatment modality for skin cancer has increased significantly over the last decade with standardized applicators. Utilizing 3D printing, the ability to make applicators specifically designed for each patient’s anatomy has become economically feasible. With this in mind it was the aim of this study to determine the dosimetric accuracy of a 3-D printed HDR brachytherapy applicator for the skin. Methods: A CT reference image was used to generate a custom applicator based on an anthropomorphic head and neck phantom. To create the applicator a 1cm expansion anteriorly with 0.5cmX0.5cm trenches on the outermore » surface that were spaced 1cm sup-inf to accommodate standard 6F flexible catheters. The applicator was printed using PLA material using a printrbot simple printer. A treatment plan optimized to deliver a clinically representative volume was created in Oncentra and delivered with a nucletron afterloader. Measurements were made using TLDs and EBT3 gafchromic film that were placed between the applicator and the phantom’s forehead. An additional piece of film was also used to qualitatively asses the dose distribution in the transverse plane. Using a standard vaginal cylinder and bolus, a standardized curve correlating TLD and film exposure-to-radiation dose was established by irradiating film to known doses (200,500,700 cGy) at a 3.5 cm radius distance. Results: Evaluated TLDs showed the absolute dose delivered to the skin surface using the 3-D printed bolus was 615cGy±6%, with a mean predicted TPS value in the measured area of 617.5±7%. Additionally, planar dose distributions had good qualitative agreement with calculated TPS isodoses. Conclusion: This work demonstrates patient specific 3-D printed HDR brachytherapy applicators for skin cancer treatments are practical and accurate in TPS calculations but additional measurements are needed to verify additional sites and dose at depth.« less

  13. Definitive radiotherapy for primary vaginal cancer: correlation between treatment patterns and recurrence rate.

    PubMed

    Kanayama, Naoyuki; Isohashi, Fumiaki; Yoshioka, Yasuo; Baek, Sungjae; Chatani, Masashi; Kotsuma, Tadayuki; Tanaka, Eiichi; Yoshida, Ken; Seo, Yuji; Suzuki, Osamu; Mabuchi, Seiji; Shiki, Yasuhiko; Tatsumi, Keiji; Kimura, Tadashi; Teshima, Teruki; Ogawa, Kazuhiko

    2015-03-01

    The purpose of this study was to determine the outcomes and optimal practice patterns of definitive radiotherapy for primary vaginal cancer. Between 1993 and 2012, 49 patients were treated with definitive radiotherapy for primary vaginal cancer in three hospitals. Of these, 15 patients (31%) had clinically positive regional lymph node metastasis. A total of 34 patients (70%) received external beam radiotherapy with high-dose-rate brachytherapy (interstitial or intracavitary), and 8 (16%) (with small superficial Stage I tumors) were treated with local radiotherapy. The median follow-up was 33 months (range: 1-169 months). The 3-year overall survival (OS), disease-free survival (DFS), and loco-regional control (LRC) rates were 83%, 59% and 71%, respectively. In multivariate analysis, the histological type (P = 0.044) was significant risk factors for LRC. In Federation of Gynecology and Obstetrics (FIGO) Stage I cases, 3 of 8 patients (38%) who did not undergo prophylactic lymph node irradiation had lymph node recurrence, compared with 2 of 12 patients (17%) who underwent prophylactic pelvic irradiation. For Stage III-IV tumors, the local recurrence rate was 50% and the lymph node recurrence rate was 40%. Patients with FIGO Stage I/II or clinical Stage N1 had a higher recurrence rate with treatment using a single modality compared with the recurrence rate using combined modalities. In conclusion, our treatment outcomes for vaginal cancer were acceptable, but external beam radiotherapy with brachytherapy (interstitial or intracavitary) was needed regardless of FIGO stage. Improvement of treatment outcomes in cases of FIGO Stage III or IV remains a significant challenge. © The Author 2015. Published by Oxford University Press on behalf of The Japan Radiation Research Society and Japanese Society for Radiation Oncology.

  14. SU-F-T-18: The Importance of Immobilization Devices in Brachytherapy Treatments of Vaginal Cuff

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Shojaei, M; Dumitru, N; Pella, S

    2016-06-15

    Purpose: High dose rate brachytherapy is a highly localized radiation therapy that has a very high dose gradient. Thus one of the most important parts of the treatment is the immobilization. The smallest movement of the patient or applicator can result in dose variation to the surrounding tissues as well as to the tumor to be treated. We will revise the ML Cylinder treatments and their localization challenges. Methods: A retrospective study of 25 patients with 5 treatments each looking into the applicator’s placement in regard to the organs at risk. Motion possibilities for each applicator intra and inter fractionationmore » with their dosimetric implications were covered and measured in regard with their dose variance. The localization immobilization devices used were assessed for the capability to prevent motion before and during the treatment delivery. Results: We focused on the 100% isodose on central axis and a 15 degree displacement due to possible rotation analyzing the dose variations to the bladder and rectum walls. The average dose variation for bladder was 15% of the accepted tolerance, with a minimum variance of 11.1% and a maximum one of 23.14% on the central axis. For the off axis measurements we found an average variation of 16.84% of the accepted tolerance, with a minimum variance of 11.47% and a maximum one of 27.69%. For the rectum we focused on the rectum wall closest to the 120% isodose line. The average dose variation was 19.4%, minimum 11.3% and a maximum of 34.02% from the accepted tolerance values Conclusion: Improved immobilization devices are recommended. For inter-fractionation, localization devices are recommended in place with consistent planning in regards with the initial fraction. Many of the present immobilization devices produced for external radiotherapy can be used to improve the localization of HDR applicators during transportation of the patient and during treatment.« less

  15. Dose distribution verification for GYN brachytherapy using EBT Gafchromic film and TG-43 calculation.

    PubMed

    Gholami, Somayeh; Mirzaei, Hamid Reza; Jabbary Arfaee, Ali; Jaberi, Ramin; Nedaie, Hassan Ali; Rabi Mahdavi, Seied; Rajab Bolookat, Eftekhar; Meigooni, Ali S

    2016-01-01

    Verification of dose distributions for gynecological (GYN) brachytherapy implants using EBT Gafchromic film. One major challenge in brachytherapy is to verify the accuracy of dose distributions calculated by a treatment planning system. A new phantom was designed and fabricated using 90 slabs of 18 cm × 16 cm × 0.2 cm Perspex to accommodate a tandem and Ovoid assembly, which is normally used for GYN brachytherapy treatment. This phantom design allows the use of EBT Gafchromic films for dosimetric verification of GYN implants with a cobalt-60 HDR system or a LDR Cs-137 system. Gafchromic films were exposed using a plan that was designed to deliver 1.5 Gy of dose to 0.5 cm distance from the lateral surface of ovoids from a pair of ovoid assembly that was used for treatment vaginal cuff. For a quantitative analysis of the results for both LDR and HDR systems, the measured dose values at several points of interests were compared with the calculated data from a commercially available treatment planning system. This planning system was utilizing the TG-43 formalism and parameters for calculation of dose distributions around a brachytherapy implant. The results of these investigations indicated that the differences between the calculated and measured data at different points were ranging from 2.4% to 3.8% for the LDR Cs-137 and HDR Co-60 systems, respectively. The EBT Gafchromic films combined with the newly designed phantom could be utilized for verification of the dose distributions around different GYN implants treated with either LDR or HDR brachytherapy procedures.

  16. In Vivo Dosimetry of High-Dose-Rate Interstitial Brachytherapy in the Pelvic Region: Use of a Radiophotoluminescence Glass Dosimeter for Measurement of 1004 Points in 66 Patients With Pelvic Malignancy

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Nose, Takayuki; Department of Physics, Cancer Institute of the Japanese Foundation for Cancer Research, Tokyo; Koizumi, Masahiko

    2008-02-01

    Purpose: To perform the largest in vivo dosimetry study for interstitial brachytherapy yet to be undertaken using a new radiophotoluminescence glass dosimeter (RPLGD) in patients with pelvic malignancy and to study the limits of contemporary planning software based on the results. Patients and Methods: Sixty-six patients with pelvic malignancy were treated with high-dose-rate interstitial brachytherapy, including prostate (n = 26), gynecological (n = 35), and miscellaneous (n = 5). Doses for a total of 1004 points were measured by RPLGDs and calculated with planning software in the following locations: rectum (n = 549), urethra (n = 415), vagina (n =more » 25), and perineum (n = 15). Compatibility (measured dose/calculated dose) was analyzed according to dosimeter location. Results: The compatibility for all dosimeters was 0.98 {+-} 0.23, stratified by location: rectum, 0.99 {+-} 0.20; urethra, 0.96 {+-} 0.26; vagina, 0.91 {+-} 0.08; and perineum, 1.25 {+-} 0.32. Conclusions: Deviations between measured and calculated doses for the rectum and urethra were greater than 20%, which is attributable to the independent movements of these organs and the applicators. Missing corrections for inhomogeneity are responsible for the 9% negative shift near the vaginal cylinder (specific gravity = 1.24), whereas neglect of transit dose contributes to the 25% positive shift in the perineal dose. Dose deviation of >20% for nontarget organs should be taken into account in the planning process. Further development of planning software and a real-time dosimetry system are necessary to use the current findings and to achieve adaptive dose delivery.« less

  17. Patterns of brachytherapy practice for patients with carcinoma of the cervix (1996-1999): a patterns of care study.

    PubMed

    Erickson, Beth; Eifel, Patricia; Moughan, Jennifer; Rownd, Jason; Iarocci, Thomas; Owen, Jean

    2005-11-15

    or interstitial, respectively; in facilities that treated fewer patients, 3.4% had HDR brachytherapy, and only 1.2% had interstitial brachytherapy. Patients treated with LDR intracavitary radiotherapy had one (23.5%), two (74.1%), or three (2.4%) implants. For patients treated with curative intent who completed radiation therapy with LDR intracavitary radiation therapy without hysterectomy, the median brachytherapy dose to Point A was 40.3 Gy, and the median total dose to Point A was 82.9 Gy. Patients were treated with HDR intracavitary radiation therapy using a variety of treatment schedules using 1-2 fractions (7.5%), 3-4 fractions (17.4%), 5-6 fractions (38.5%), 7-9 fractions (33.5%), or 12 fractions (3%). Fraction sizes were <500 cGy (29.5%), 500-<600 (25.2%), 600 (28.1%), >600 (8%), or unknown (9.2%). For patients treated with HDR, the median total dose to Point A (corrected for fraction size using a alpha/beta = 10) was 85.8 Gy (range: 56.2-116.1 Gy). At institutions treating <500 new patients per year, the percentage of patients receiving a brachytherapy dose <40 Gy was significantly higher than at institutions treating > or =500 new patients per year (p < 0.0001). For LDR intracavitary radiation therapy, 5.8% had neither bladder nor rectal doses recorded for any of their implants, whereas in HDR intracavitary radiation therapy, 73.4% had neither bladder nor rectal doses recorded for any of their implants. The median total duration of radiation therapy was identical for patients who had HDR or LDR intracavitary radiation therapy (57 days). For LDR at institutions treating <500 new patients per year, the percentage of patients with treatment duration >56 days was significantly greater than at institutions > or =500 new patients per year (p = 0.002). Of the patients who had LDR intracavitary radiation therapy implants, 65% were treated using tandem and shielded Fletcher-Suit-Delclos colpostats; other patients had mini ovoids (10.9%), cylinders (3.9%), Henschke

  18. SU-F-T-50: Evaluation of Monte Carlo Simulations Performance for Pediatric Brachytherapy Dosimetry

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Chatzipapas, C; Kagadis, G; Papadimitroulas, P

    Purpose: Pediatric tumors are generally treated with multi-modal procedures. Brachytherapy can be used with pediatric tumors, especially given that in this patient population low toxicity on normal tissues is critical as is the suppression of the probability for late malignancies. Our goal is to validate the GATE toolkit on realistic brachytherapy applications, and evaluate brachytherapy plans on pediatrics for accurate dosimetry on sensitive and critical organs of interest. Methods: The GATE Monte Carlo (MC) toolkit was used. Two High Dose Rate (HDR) 192Ir brachytherapy sources were simulated (Nucletron mHDR-v1 and Varian VS2000), and fully validated using the AAPM and ESTROmore » protocols. A realistic brachytherapy plan was also simulated using the XCAT anthropomorphic computational model .The simulated data were compared to the clinical dose points. Finally, a 14 years old girl with vaginal rhabdomyosarcoma was modelled based on clinical procedures for the calculation of the absorbed dose per organ. Results: The MC simulations resulted in accurate dosimetry in terms of dose rate constant (Λ), radial dose gL(r) and anisotropy function F(r,θ) for both sources.The simulations were executed using ∼1010 number of primaries resulting in statistical uncertainties lower than 2%.The differences between the theoretical values and the simulated ones ranged from 0.01% up to 3.3%, with the largest discrepancy (6%) being observed in the dose rate constant calculation.The simulated DVH using an adult female XCAT model was also compared to a clinical one resulting in differences smaller than 5%. Finally, a realistic pediatric brachytherapy simulation was performed to evaluate the absorbed dose per organ and to calculate DVH with respect to heterogeneities of the human anatomy. Conclusion: GATE is a reliable tool for brachytherapy simulations both for source modeling and for dosimetry in anthropomorphic voxelized models. Our project aims to evaluate a variety of pediatric

  19. [Brachytherapy training].

    PubMed

    Hannoun-Lévi, J-M; Marchesi, V; Peiffert, D

    2013-04-01

    Treatment technique training needs theoretical and practical knowledge allowing proposing the right treatment for the right patient, but also allowing performing the technical gesture in the best conditions for an optimal result with a maximal security. The evolution of the brachytherapy techniques needs the set up of specific theoretical and practical training sessions. The present article focuses on the importance of the brachytherapy training as well as the different means currently available for the young radiation oncologist community for perfecting their education. National and international trainings are presented. The role of the simulation principle in the frame of brachytherapy is also discussed. Even if brachytherapy is not always an easy technique, its efficacy and its medico-economical impact need to be passed down to motivated students with the implementation of relevant educational means. Copyright © 2013 Société française de radiothérapie oncologique (SFRO). Published by Elsevier SAS. All rights reserved.

  20. MRI-guided brachytherapy

    PubMed Central

    Tanderup, Kari; Viswanathan, Akila; Kirisits, Christian; Frank, Steven J.

    2014-01-01

    The application of MRI-guided brachytherapy has demonstrated significant growth during the last two decades. Clinical improvements in cervix cancer outcomes have been linked to the application of repeated MRI for identification of residual tumor volumes during radiotherapy. This has changed clinical practice in the direction of individualized dose administration, and mounting evidence of improved clinical outcome with regard to local control, overall survival as well as morbidity. MRI-guided prostate HDR and LDR brachytherapy has improved the accuracy of target and organs-at-risk (OAR) delineation, and the potential exists for improved dose prescription and reporting for the prostate gland and organs at risk. Furthermore, MRI-guided prostate brachytherapy has significant potential to identify prostate subvolumes and dominant lesions to allow for dose administration reflecting the differential risk of recurrence. MRI-guided brachytherapy involves advanced imaging, target concepts, and dose planning. The key issue for safe dissemination and implementation of high quality MRI-guided brachytherapy is establishment of qualified multidisciplinary teams and strategies for training and education. PMID:24931089

  1. Newly developed vaginal atrophy symptoms II and vaginal pH: a better correlation in vaginal atrophy?

    PubMed

    Tuntiviriyapun, P; Panyakhamlerd, K; Triratanachat, S; Chatsuwan, T; Chaikittisilpa, S; Jaisamrarn, U; Taechakraichana, N

    2015-04-01

    The primary objective of this study was to evaluate the correlation among symptoms, signs, and the number of lactobacilli in postmenopausal vaginal atrophy. The secondary objective was to develop a new parameter to improve the correlation. A cross-sectional descriptive study. Naturally postmenopausal women aged 45-70 years with at least one clinical symptom of vaginal atrophy of moderate to severe intensity were included in this study. All of the objective parameters (vaginal atrophy score, vaginal pH, the number of lactobacilli, vaginal maturation index, and vaginal maturation value) were evaluated and correlated with vaginal atrophy symptoms. A new parameter of vaginal atrophy, vaginal atrophy symptoms II, was developed and consists of the two most bothersome symptoms (vaginal dryness and dyspareunia). Vaginal atrophy symptoms II was analyzed for correlation with the objective parameters. A total of 132 naturally postmenopausal women were recruited for analysis. Vaginal pH was the only objective parameter found to have a weak correlation with vaginal atrophy symptoms (r = 0.273, p = 0.002). The newly developed vaginal atrophy symptoms II parameter showed moderate correlation with vaginal pH (r = 0.356, p < 0.001) and a weak correlation with the vaginal atrophy score (r = 0.230, p < 0.001). History of sexual intercourse within 3 months was associated with a better correlation between vaginal atrophy symptoms and the objective parameters. Vaginal pH was significantly correlated with vaginal atrophy symptoms. The newly developed vaginal atrophy symptoms II was associated with a better correlation. The vaginal atrophy symptoms II and vaginal pH may be better tools for clinical evaluation and future study of the vaginal ecosystem.

  2. New era of electronic brachytherapy

    PubMed Central

    Ramachandran, Prabhakar

    2017-01-01

    Traditional brachytherapy refers to the placement of radioactive sources on or inside the cancer tissues. Based on the type of sources, brachytherapy can be classified as radionuclide and electronic brachytherapy. Electronic brachytherapy uses miniaturized X-ray sources instead of radionuclides to deliver high doses of radiation. The advantages of electronic brachytherapy include low dose to organs at risk, reduced dose to treating staff, no leakage radiation in off state, less shielding, and no radioactive waste. Most of these systems operate between 50 and 100 kVp and are widely used in the treatment of skin cancer. Intrabeam, Xoft and Papillon systems are also used in the treatment of intra-operative radiotherapy to breast in addition to other treatment sites. The rapid fall-off in the dose due to its low energy is a highly desirable property in brachytherapy and results in a reduced dose to the surrounding normal tissues compared to the Ir-192 source. The Xoft Axxent brachytherapy system uses a 2.25 mm miniaturized X-ray tube and the source almost mimics the high dose rate Ir-192 source in terms of dose rate and it is the only electronic brachytherapy system specifically used in the treatment of cervical cancers. One of the limiting factors that impede the use of electronic brachytherapy for interstitial application is the source dimension. However, it is highly anticipated that the design of miniaturized X-ray tube closer to the dimension of an Ir-192 wire is not too far away, and the new era of electronic brachytherapy has just begun. PMID:28529679

  3. Vaginal disorders.

    PubMed

    Soderberg, S F

    1986-05-01

    Chronic vaginitis is the most common vaginal disorder. Dogs with vaginitis show no signs of systemic illness but often lick at the vulva and have purulent or hemorrhagic vaginal discharges. Vaginitis is most commonly secondary to a noninfectious inciting factor such as congenital vaginal anomalies, clitoral hypertrophy, foreign bodies, trauma to the vaginal mucosa, or vaginal tumors. Inspection of the caudal vagina and vestibule both visually and digitally will often reveal the source of vaginal irritation. Vaginal cytology is used to establish the stage of the estrous cycle as well as distinguish uterine from vaginal sources of discharge. Vaginal cultures are used to establish the predominant offending organism associated with vaginal discharges and may be used as a guide for selection of a therapeutic agent. Vaginitis is best managed by removing the inciting cause and treating the area locally with antiseptic douches. Congenital malformations at the vestibulovaginal or vestibulovulvar junction may prevent normal intromission. Affected bitches may be reluctant to breed naturally because of pain. Such defects are detected best by digital examination. Congenital vaginal defects may be corrected by digital or surgical means. Prolapse of tissue through the lips of the vulva may be caused by clitoral hypertrophy, vaginal hyperplasia, or vaginal tumors. Enlargement of clitoral tissue is the result of endogenous or exogenous sources of androgens. Treatment of this condition includes removal of the androgen source and/or surgical removal of clitoral tissue. Vaginal hyperplasia is detected during proestrus or estrus of young bitches. Hyperplastic tissue will regress during diestrus. Tissue that is excessively traumatized and/or prolapse of the entire vaginal circumference may be removed surgically. Ovariohysterectomy may be used to prevent recurrence. Vaginal tumors are detected most often in older intact bitches. Such tumors are generally of smooth muscle or fibrous

  4. Monte Carlo dose calculations for high-dose-rate brachytherapy using GPU-accelerated processing.

    PubMed

    Tian, Z; Zhang, M; Hrycushko, B; Albuquerque, K; Jiang, S B; Jia, X

    2016-01-01

    Current clinical brachytherapy dose calculations are typically based on the Association of American Physicists in Medicine Task Group report 43 (TG-43) guidelines, which approximate patient geometry as an infinitely large water phantom. This ignores patient and applicator geometries and heterogeneities, causing dosimetric errors. Although Monte Carlo (MC) dose calculation is commonly recognized as the most accurate method, its associated long computational time is a major bottleneck for routine clinical applications. This article presents our recent developments of a fast MC dose calculation package for high-dose-rate (HDR) brachytherapy, gBMC, built on a graphics processing unit (GPU) platform. gBMC-simulated photon transport in voxelized geometry with physics in (192)Ir HDR brachytherapy energy range considered. A phase-space file was used as a source model. GPU-based parallel computation was used to simultaneously transport multiple photons, one on a GPU thread. We validated gBMC by comparing the dose calculation results in water with that computed TG-43. We also studied heterogeneous phantom cases and a patient case and compared gBMC results with Acuros BV results. Radial dose function in water calculated by gBMC showed <0.6% relative difference from that of the TG-43 data. Difference in anisotropy function was <1%. In two heterogeneous slab phantoms and one shielded cylinder applicator case, average dose discrepancy between gBMC and Acuros BV was <0.87%. For a tandem and ovoid patient case, good agreement between gBMC and Acruos BV results was observed in both isodose lines and dose-volume histograms. In terms of the efficiency, it took ∼47.5 seconds for gBMC to reach 0.15% statistical uncertainty within the 5% isodose line for the patient case. The accuracy and efficiency of a new GPU-based MC dose calculation package, gBMC, for HDR brachytherapy make it attractive for clinical applications. Copyright © 2016 American Brachytherapy Society. Published by

  5. Image Guided Cervical Brachytherapy: 2014 Survey of the American Brachytherapy Society

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Grover, Surbhi, E-mail: Surbhi.grover@uphs.upenn.edu; Harkenrider, Matthew M.; Cho, Linda P.

    Purpose: To provide an update of the 2007 American brachytherapy survey on image-based brachytherapy, which showed that in the setting of treatment planning for gynecologic brachytherapy, although computed tomography (CT) was often used for treatment planning, most brachytherapists used point A for dose specification. Methods and Materials: A 45-question electronic survey on cervical cancer brachytherapy practice patterns was sent to all American Brachytherapy Society members and additional radiation oncologists and physicists based in the United States between January and September 2014. Responses from the 2007 survey and the present survey were compared using the χ{sup 2} test. Results: There weremore » 370 respondents. Of those, only respondents, not in training, who treat more than 1 cervical cancer patient per year and practice in the United States, were included in the analysis (219). For dose specification to the target (cervix and tumor), 95% always use CT, and 34% always use MRI. However, 46% use point A only for dose specification to the target. There was a lot of variation in parameters used for dose evaluation of target volume and normal tissues. Compared with the 2007 survey, use of MRI has increased from 2% to 34% (P<.0001) for dose specification to the target. Use of volume-based dose delineation to the target has increased from 14% to 52% (P<.0001). Conclusion: Although use of image-based brachytherapy has increased in the United States since the 2007 survey, there is room for further growth, particularly with the use of MRI. This increase may be in part due to educational initiatives. However, there is still significant heterogeneity in brachytherapy practice in the United States, and future efforts should be geared toward standardizing treatment.« less

  6. Vaginal toxic shock reaction triggering desquamative inflammatory vaginitis.

    PubMed

    Pereira, Nigel; Edlind, Thomas D; Schlievert, Patrick M; Nyirjesy, Paul

    2013-01-01

    The study aimed to report 2 cases of desquamative inflammatory vaginitis associated with toxic shock syndrome toxin 1 (TSST-1)-producing Staphylococcus aureus strains. Case report of 2 patients, 1 with an acute and 1 with a chronic presentation, diagnosed with desquamative inflammatory vaginitis on the basis of clinical findings and wet mount microscopy. Pretreatment and posttreatment vaginal bacterial and yeast cultures were obtained. Pretreatment vaginal bacterial cultures from both patients grew TSST-1-producing S. aureus. Subsequent vaginal bacterial culture results after oral antibiotic therapy were negative. Desquamative inflammatory vaginitis may be triggered through TSST-1-mediated vaginal toxic shock reaction.

  7. External Pelvic and Vaginal Irradiation Versus Vaginal Irradiation Alone as Postoperative Therapy in Medium-Risk Endometrial Carcinoma-A Prospective Randomized Study

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Sorbe, Bengt, E-mail: bengt.sorbe@orebroll.se; Horvath, Gyoergy; Andersson, Hakan

    Purpose: To evaluate the value of adjuvant external beam pelvic radiotherapy as adjunct to vaginal brachytherapy (VBT) in medium-risk endometrial carcinoma, with regard to locoregional tumor control, recurrences, survival, and toxicity. Methods and Materials: Consecutive series of 527 evaluable patients were included in this randomized trial. Median follow-up for patients alive was 62 months. The primary study endpoints were locoregional recurrences and overall survival. Secondary endpoints were recurrence-free survival, recurrence-free interval, cancer-specific survival, and toxicity. Results: Five-year locoregional relapse rates were 1.5% after external beam radiotherapy (EBRT) plus VBT and 5% after vaginal irradiation alone (p = 0.013), and 5-yearmore » overall survival rates were 89% and 90%, respectively (p = 0.548). Endometrial cancer-related death rates were 3.8% after EBRT plus VBT and 6.8% after VBT (p = 0.118). Pelvic recurrences (exclusively vaginal recurrence) were reduced by 93% by the addition of EBRT to VBT. Deep myometrial infiltration was a significant prognostic factor in this medium-risk group of endometrioid carcinomas but not International Federation of Gynecology and Obstetrics grade or DNA ploidy. Combined radiotherapy was well tolerated, with serious (Grade 3) late side effects of less than 2%. However, there was a significant difference in favor of VBT alone. Conclusions: Despite a significant locoregional control benefit with combined radiotherapy, no survival improvement was recorded, but increased late toxicity was noted in the intestine, bladder, and vagina. Combined RT should probably be reserved for high-risk cases with two or more high-risk factors. VBT alone should be the adjuvant treatment option for purely medium-risk cases.« less

  8. Clinical outcomes from an innovative protocol using serial ultrasound imaging and a single MR image to guide brachytherapy for locally advanced cervix cancer.

    PubMed

    van Dyk, Sylvia; Narayan, Kailash; Bernshaw, David; Kondalsamy-Chennakesavan, Srinivas; Khaw, Pearly; Lin, Ming Yin; Schneider, Michal

    The aim of this study was to report clinical outcomes in a series of patients who underwent serial ultrasound and a single MRI to plan and verify intracavitary brachytherapy. Data for patients who were referred for curative intent radiotherapy for International Federation of Gynecology and Obstetrics (FIGO) Stage 1-1V cervix cancer between January 2007 and March 2012 were analyzed. All patients received external beam radiotherapy with concurrent chemotherapy and sequential high-dose rate brachytherapy. Brachytherapy was planned and verified using serial ultrasound imaging and a single MRI. Data from 191 patients were available for analyses. The median (range) followup time was 5.08 (0.25-8.25) years. Five-year local control, failure-free survival, cancer-specific survival, and overall survival were 86%, 57.3%, 70% and 63%, respectively. Mean (standard deviation) combined external beam radiotherapy and brachytherapy target doses, equivalent to doses in 2 Gy fractions were 80.4 Gy10 (3.89), median (range) 80 (49-96) Gy10. Grade 3 or greater gastrointestinal, genitourinary, or vaginal late toxicity occurred in 3%, 1.6%, and 2% of patients, respectively. Survival, patterns of failure, and late complication rates were similar to published series of MRI/CT-based brachytherapy practices. This large study demonstrates that favorable treatment outcomes can be obtained using a pragmatic and innovative combination of ultrasound and MR imaging. Crown Copyright © 2016. Published by Elsevier Inc. All rights reserved.

  9. Non-specific vaginitis or vaginitis of undetermined aetiology.

    PubMed

    Faro, S; Phillips, L E

    1987-01-01

    Vaginitis is a complex syndrome that is probably the most common outpatient disease seen by the gynaecologist. The specific aetiologies of vaginitis are many. One of the most common entities, however, is "non-specific vaginitis" which can be subdivided into: Gardnerella vaginitis, anaerobic vaginosis, and vaginitis of undetermined aetiology. The role of Gardnerella as a causative agent for vaginitis has been studied in depth but its specific role remains controversial. Anaerobic vaginosis can be diagnosed by noting on microscopic examination the presence of clue cells, free-floating bacteria and numerous white blood cells (WBC's). Culturing an aliquot of the vaginal discharge reveals a high number of anaerobes. In addition, this condition responds to antibiotics effective against anaerobes, e.g., metronidazole. Vaginitis of undetermined aetiology is more complex and is characterized by a purulent vaginal discharge, a pH of 4.0-4.6, numerous WBC's, and a high concentration of bacteria. The microbiology of this vaginitis includes many facultative Gram-negative rods and Gram-positive cocci. Anaerobes may be present but do not make up a large component of the endogenous microflora. This condition does not respond to the usual antibiotic therapies employed in treating bacterial vaginitis. Since this condition appears to be primarily an inflammatory reaction, it may be responsive to topical antiinflammatory agents such as benzydamine.

  10. Vaginal cancer

    MedlinePlus

    Vaginal cancer; Cancer - vagina; Tumor - vaginal ... Most vaginal cancers occur when another cancer, such as cervical or endometrial cancer , spreads. This is called secondary vaginal cancer. Cancer ...

  11. Dosimetric audit in brachytherapy

    PubMed Central

    Bradley, D A; Nisbet, A

    2014-01-01

    Dosimetric audit is required for the improvement of patient safety in radiotherapy and to aid optimization of treatment. The reassurance that treatment is being delivered in line with accepted standards, that delivered doses are as prescribed and that quality improvement is enabled is as essential for brachytherapy as it is for the more commonly audited external beam radiotherapy. Dose measurement in brachytherapy is challenging owing to steep dose gradients and small scales, especially in the context of an audit. Several different approaches have been taken for audit measurement to date: thimble and well-type ionization chambers, thermoluminescent detectors, optically stimulated luminescence detectors, radiochromic film and alanine. In this work, we review all of the dosimetric brachytherapy audits that have been conducted in recent years, look at current audits in progress and propose required directions for brachytherapy dosimetric audit in the future. The concern over accurate source strength measurement may be essentially resolved with modern equipment and calibration methods, but brachytherapy is a rapidly developing field and dosimetric audit must keep pace. PMID:24807068

  12. Vaginal Atrophy

    MedlinePlus

    ... an Endocrinologist Search Featured Resource Menopause Map™ View Vaginal Atrophy October 2017 Download PDFs English Editors Christine ... during this time, including vaginal dryness. What is vaginal atrophy? Vaginal atrophy (also referred to as vulvovaginal ...

  13. Vaginal health in contraceptive vaginal ring users - A review.

    PubMed

    Lete, Iñaki; Cuesta, María C; Marín, Juan M; Guerra, Sandra

    2013-08-01

    To provide an overview of the available data from clinical studies of vaginal conditions in women who use a vaginal ring as a contraceptive. A systematic review of the literature. Millions of women have already used the ethylene vinyl acetate vaginal ring that releases ethinylestradiol and etonogestrel for contraception. Because of its small size, more than four out of five women using the ring report that they do not feel it, even during sexual intercourse. No colposcopic or cytological changes have been observed in users, although approximately 10% have increased vaginal discharge. While in vitro studies have shown adhesion of Candida yeasts to the vaginal ring surface, clinical studies have not demonstrated a greater incidence of Candida infections compared to users of equivalent oral contraceptives. Some clinical studies suggest a lower incidence of bacterial vaginosis. No interaction exists between concomitant use of the vaginal ring and other drugs or products for vaginal use. The use of a contraceptive vaginal ring does not alter the vaginal ecosystem and therefore does not substantially affect vaginal health.

  14. Analysis of Vaginal Cell Populations during Experimental Vaginal Candidiasis

    PubMed Central

    Fidel, Paul L.; Luo, Wei; Steele, Chad; Chabain, Joseph; Baker, Marc; Wormley, Floyd

    1999-01-01

    Studies with an estrogen-dependent murine model of vaginal candidiasis suggest that local cell-mediated immunity (CMI) is more important than systemic CMI for protection against vaginitis. The present study, however, showed that, compared to uninfected mice, little to no change in the percentage or types of vaginal T cells occurred during a primary vaginal infection or during a secondary vaginal infection where partial protection was observed. Furthermore, depletion of polymorphonuclear leukocytes (PMN) had no effect on infection in the presence or absence of pseudoestrus. These results indicate a lack of demonstrable effects by systemic CMI or PMN against vaginitis and suggest that if local T cells are important, they are functioning without showing significant increases in numbers within the vaginal mucosa during infection. PMID:10338532

  15. An investigation of a PRESAGE® in-vivo dosimeter for brachytherapy

    PubMed Central

    Vidovic, A K; Juang, T; Meltsner, S; Adamovics, J; Chino, J; Steffey, B; Craciunescu, O; Oldham, M

    2014-01-01

    Determining accurate in-vivo dosimetry in brachytherapy treatment with high dose gradients is challenging. Here we introduce, investigate, and characterize a novel in-vivo dosimeter and readout technique with the potential to address this problem. A cylindrical (4 mm x 20 mm) tissue equivalent radiochromic dosimeter PRESAGE® In-Vivo (PRESAGE®-IV) is investigated. Two readout methods of the radiation induced change in optical density (OD) were investigated: (i) volume-averaged readout by spectrophotometer, and (ii) a line profile readout by 2D projection imaging utilizing a high-resolution (50 micron) telecentric optical system. Method (i) is considered the gold standard when applied to PRESAGE® in optical cuvettes. The feasibility of both methods was evaluated by comparison to standard measurements on PRESAGE® in optical cuvettes via spectrophotometer. An end-to-end feasibility study was performed by a side-by-side comparison with TLDs in an 192Ir HDR delivery. 7 and 8 Gy was delivered to PRESAGE®-IV and TLDs attached to the surface of a vaginal cylinder. Known geometry enabled direct comparison of measured dose with commissioned treatment planning system. A high-resolution readout study under a steep dose gradient region showed 98.9% (5%/1 mm) agreement between PRESAGE®-IV and Gafchromic® EBT2 Film. Spectrometer measurements exhibited a linear dose response between 0–15 Gy with sensitivity of 0.0133 ± 0.0007 ΔOD/(Gy·cm) at the 95% confidence interval. Method (ii) yielded a linear response with sensitivity of 0.0132 ± 0.0006 (ΔOD/Gy), within 2% of method (i). Method (i) has poor spatial resolution due to volume averaging. Method (ii) has higher resolution (~1mm) without loss of sensitivity or increased noise. Both readout methods are shown to be feasible. The end-to-end comparison revealed a 2.5% agreement between PRESAGE®-IV and treatment plan in regions of uniform high dose. PRESAGE®-IV shows promise for in-vivo dose verification, although

  16. An investigation of a PRESAGE® in vivo dosimeter for brachytherapy

    NASA Astrophysics Data System (ADS)

    Vidovic, A. K.; Juang, T.; Meltsner, S.; Adamovics, J.; Chino, J.; Steffey, B.; Craciunescu, O.; Oldham, M.

    2014-07-01

    Determining accurate in vivo dosimetry in brachytherapy treatment with high dose gradients is challenging. Here we introduce, investigate, and characterize a novel in vivo dosimeter and readout technique with the potential to address this problem. A cylindrical (4 mm × 20 mm) tissue equivalent radiochromic dosimeter PRESAGE® in vivo (PRESAGE®-IV) is investigated. Two readout methods of the radiation induced change in optical density (OD) were investigated: (i) volume-averaged readout by spectrophotometer, and (ii) a line profile readout by 2D projection imaging utilizing a high-resolution (50 micron) telecentric optical system. Method (i) is considered the gold standard when applied to PRESAGE® in optical cuvettes. The feasibility of both methods was evaluated by comparison to standard measurements on PRESAGE® in optical cuvettes via spectrophotometer. An end-to-end feasibility study was performed by a side-by-side comparison with TLDs in an 192Ir HDR delivery. 7 and 8 Gy was delivered to PRESAGE®-IV and TLDs attached to the surface of a vaginal cylinder. Known geometry enabled direct comparison of measured dose with a commissioned treatment planning system. A high-resolution readout study under a steep dose gradient region showed 98.9% (5%/1 mm) agreement between PRESAGE®-IV and Gafchromic® EBT2 Film. Spectrometer measurements exhibited a linear dose response between 0-15 Gy with sensitivity of 0.0133 ± 0.0007 ΔOD/(Gy ṡ cm) at the 95% confidence interval. Method (ii) yielded a linear response with sensitivity of 0.0132 ± 0.0006 (ΔOD/Gy), within 2% of method (i). Method (i) has poor spatial resolution due to volume averaging. Method (ii) has higher resolution (˜1 mm) without loss of sensitivity or increased noise. Both readout methods are shown to be feasible. The end-to-end comparison revealed a 2.5% agreement between PRESAGE®-IV and treatment plan in regions of uniform high dose. PRESAGE®-IV shows promise for in vivo dose verification

  17. Vaginal Toxic Shock Reaction Triggering Desquamative Inflammatory Vaginitis

    PubMed Central

    Pereira, Nigel; Edlind, Thomas D.; Schlievert, Patrick M.; Nyirjesy, Paul

    2012-01-01

    Objective To report two cases of desquamative inflammatory vaginitis (DIV) associated with toxic shock syndrome toxin-1 (TSST-1)-producing Staphylococcus aureus strains. Materials and Methods Case report of two patients, one with an acute and one with a chronic presentation, diagnosed with DIV on the basis of clinical findings and wet mount microscopy. Pre- and posttreatment vaginal bacterial and yeast cultures were obtained. Results Pretreatment vaginal bacterial cultures from both patients grew TSST-1-producing S. aureus. Subsequent vaginal bacterial cultures following oral antibiotic therapy were negative. Conclusions DIV may be triggered through TSST-1-mediated vaginal toxic shock reaction. PMID:23222054

  18. Impact of point A asymmetry on local control and survival for low dose-rate (LDR) brachytherapy in cervical cancer.

    PubMed

    Opfermann, Krisha J; Wahlquist, Amy; Watkins, John; Kohler, Matthew; Jenrette, Joseph

    2012-03-01

    To evaluate whether Point A asymmetry in low dose-rate (LDR) brachytherapy is associated with local control (LC), disease-free survival (DFS) and/or overall survival (OS). A retrospective analysis of disease control and survival outcomes was conducted for patients who underwent LDR brachytherapy for advanced cervical cancer. Institutional protocol entailed concurrent chemotherapy and whole pelvis radiotherapy (WPRT) over 5 weeks, followed by placement of Fletcher-Suit tandem and colpostat applicators at weeks 6 and 8. Objective Point A doses, 80-85 Gy, were accomplished by placement of Cesium-137 (Cs-137) sources. Cox proportional hazards regression models were used to assess associations between disease control and survival endpoints with variables of interest. The records of 50 patients with FIGO stage IB1-IVA cervical cancer undergoing LDR brachytherapy at our institution were identified. Thirty of these patients had asymmetry > 2.5%, and 11 patients had asymmetry > 5%. At a median survivor follow-up of 20.25 months, 15 patients had experienced disease failure (including 5 cervical/vaginal apex only failures and 2 failures encompassing the local site). Right/left dose asymmetry at Point A was associated with statistically significantly inferior LC (p = 0.035) and inferior DFS (p = 0.011) for patients with mean Point A dose of > 80 Gy. Insufficient evidence existed to conclude an association with OS. LDR brachytherapy may be associated with clinically significant dose asymmetry. The present study demonstrates that patients with Point A asymmetry have a higher risk of failure for DFS and LC.

  19. Impact of point A asymmetry on local control and survival for low dose-rate (LDR) brachytherapy in cervical cancer

    PubMed Central

    Wahlquist, Amy; Watkins, John; Kohler, Matthew; Jenrette, Joseph

    2012-01-01

    Purpose To evaluate whether Point A asymmetry in low dose-rate (LDR) brachytherapy is associated with local control (LC), disease-free survival (DFS) and/or overall survival (OS). Material and methods A retrospective analysis of disease control and survival outcomes was conducted for patients who underwent LDR brachytherapy for advanced cervical cancer. Institutional protocol entailed concurrent chemotherapy and whole pelvis radiotherapy (WPRT) over 5 weeks, followed by placement of Fletcher-Suit tandem and colpostat applicators at weeks 6 and 8. Objective Point A doses, 80-85 Gy, were accomplished by placement of Cesium-137 (Cs-137) sources. Cox proportional hazards regression models were used to assess associations between disease control and survival endpoints with variables of interest. Results The records of 50 patients with FIGO stage IB1-IVA cervical cancer undergoing LDR brachytherapy at our institution were identified. Thirty of these patients had asymmetry > 2.5%, and 11 patients had asymmetry > 5%. At a median survivor follow-up of 20.25 months, 15 patients had experienced disease failure (including 5 cervical/vaginal apex only failures and 2 failures encompassing the local site). Right/left dose asymmetry at Point A was associated with statistically significantly inferior LC (p = 0.035) and inferior DFS (p = 0.011) for patients with mean Point A dose of > 80 Gy. Insufficient evidence existed to conclude an association with OS. Conclusions LDR brachytherapy may be associated with clinically significant dose asymmetry. The present study demonstrates that patients with Point A asymmetry have a higher risk of failure for DFS and LC. PMID:23346133

  20. Vaginal Atrophy

    MedlinePlus

    ... syndrome of menopause (GSM) increases your risk of: Vaginal infections. Changes in the acid balance of your vagina makes vaginal infections (vaginitis) more likely. Urinary problems. Urinary changes associated ...

  1. Should helical tomotherapy replace brachytherapy for cervical cancer? Case report.

    PubMed

    Hsieh, Chen-Hsi; Wei, Ming-Chow; Hsu, Yao-Peng; Chong, Ngot-Swan; Chen, Yu-Jen; Hsiao, Sheng-Mou; Hsieh, Yen-Ping; Wang, Li-Ying; Shueng, Pei-Wei

    2010-11-23

    Stereotactic body radiation therapy (SBRT) administered via a helical tomotherapy (HT) system is an effective modality for treating lung cancer and metastatic liver tumors. Whether SBRT delivered via HT is a feasible alternative to brachytherapy in treatment of locally advanced cervical cancer in patients with unusual anatomic configurations of the uterus has never been studied. A 46-year-old woman presented with an 8-month history of abnormal vaginal bleeding. Biopsy revealed squamous cell carcinoma of the cervix. Magnetic resonance imaging (MRI) showed a cervical tumor with direct invasion of the right parametrium, bilateral hydronephrosis, and multiple uterine myomas. International Federation of Gynecology and Obstetrics (FIGO) stage IIIB cervical cancer was diagnosed. Concurrent chemoradiation therapy (CCRT) followed by SBRT delivered via HT was administered instead of brachytherapy because of the presence of multiple uterine myomas with bleeding tendency. Total abdominal hysterectomy was performed after 6 weeks of treatment because of the presence of multiple uterine myomas. Neither pelvic MRI nor results of histopathologic examination at X-month follow-up showed evidence of tumor recurrence. Only grade 1 nausea and vomiting during treatment were noted. Lower gastrointestinal bleeding was noted at 14-month follow-up. No fistula formation and no evidence of haematological, gastrointestinal or genitourinary toxicities were noted on the most recent follow-up. CCRT followed by SBRT appears to be an effective and safe modality for treatment of cervical cancer. Larger-scale studies are warranted.

  2. A retrospective analysis of rectal and bladder dose for gynecological brachytherapy treatments with GZP6 HDR afterloading system.

    PubMed

    Bahreyni Toossi, Mohammad Taghi; Ghorbani, Mahdi; Makhdoumi, Yasha; Taheri, Mojtaba; Homaee Shandiz, Fatemeh; Zahed Anaraki, Siavash; Soleimani Meigooni, Ali

    2012-01-01

    The aim of this work is to evaluate rectal and bladder dose for the patients treated for gynecological cancers. The GZP6 high dose rate brachytherapy system has been recently introduced to a number of radiation therapy departments in Iran, for treatment of various tumor sites such as cervix and vagina. Our analysis was based on dose measurements for 40 insertions in 28 patients, treated by a GZP6 unit between June 2009 and November 2010. Treatments consisted of combined teletherapy and intracavitary brachytherapy. In vivo dosimetry was performed with TLD-400 chips and TLD-100 microcubes in the rectum and bladder. The average of maximum rectal and bladder dose values were found to be 7.62 Gy (range 1.72-18.55 Gy) and 5.17 Gy (range 0.72-15.85 Gy), respectively. It has been recommended by the ICRU that the maximum dose to the rectum and bladder in intracavitary treatment of vaginal or cervical cancer should be lower than 80% of the prescribed dose to point A in the Manchester system. In this study, of the total number of 40 insertions, maximum rectal dose in 29 insertions (72.5% of treatment sessions) and maximum bladder dose in 18 insertions (45% of treatments sessions) were higher than 80% of the prescribed dose to the point of dose prescription. In vivo dosimetry for patients undergoing treatment by GZP6 brachytherapy system can be used for evaluation of the quality of brachytherapy treatments by this system. This information could be used as a base for developing the strategy for treatment of patients treated with GZP6 system.

  3. Clinical outcomes of image guided radiation therapy (IGRT) with gold fiducial vaginal cuff markers for high-risk endometrial cancer.

    PubMed

    Monroe, Alan T; Pikaart, Dirk; Peddada, Anuj V

    2013-06-01

    To report two year clinical outcomes of image guided radiation therapy (IGRT) to the vaginal cuff and pelvic lymph nodes in a series of high-risk endometrial cancer patients. Twenty-six consecutive high-risk endometrial cancer patients requiring adjuvant radiation to the vaginal cuff and regional lymph nodes were treated with vaginal cuff fiducial-based IGRT. Seventeen (65%) received sequential chemotherapy, most commonly with a sandwich technique. Brachytherapy followed external radiation in 11 patients to a median dose of 18 Gy in 3 fractions. The median external beam dose delivered was 47.5 Gy in 25 fractions. All 656 fractions were successfully imaged and treated. The median overall translational shift required for correction was 9.1 mm (standard deviation, 5.2 mm) relative to clinical set-up with skin tattoos. Shifts of 1 cm, 1.5 cm, and 2 cm or greater were performed in 43%, 14%, and 4% of patients, respectively. Acute grade 2 gastrointestinal (GI) toxicity occurred in eight patients (30%) and grade 3 toxicity occurred in one. At two years, there have been no local or regional failures and actuarial overall survival is 95%. Daily image guidance for high-risk endometrial cancer results in a low incidence of acute GI/genitourinary (GU) toxicity with uncompromised tumor control at two years. Vaginal cuff translations can be substantial and may possibly result in underdosing if not properly considered.

  4. High dose rate brachytherapy for oral cancer.

    PubMed

    Yamazaki, Hideya; Yoshida, Ken; Yoshioka, Yasuo; Shimizutani, Kimishige; Furukawa, Souhei; Koizumi, Masahiko; Ogawa, Kazuhiko

    2013-01-01

    Brachytherapy results in better dose distribution compared with other treatments because of steep dose reduction in the surrounding normal tissues. Excellent local control rates and acceptable side effects have been demonstrated with brachytherapy as a sole treatment modality, a postoperative method, and a method of reirradiation. Low-dose-rate (LDR) brachytherapy has been employed worldwide for its superior outcome. With the advent of technology, high-dose-rate (HDR) brachytherapy has enabled health care providers to avoid radiation exposure. This therapy has been used for treating many types of cancer such as gynecological cancer, breast cancer, and prostate cancer. However, LDR and pulsed-dose-rate interstitial brachytherapies have been mainstays for head and neck cancer. HDR brachytherapy has not become widely used in the radiotherapy community for treating head and neck cancer because of lack of experience and biological concerns. On the other hand, because HDR brachytherapy is less time-consuming, treatment can occasionally be administered on an outpatient basis. For the convenience and safety of patients and medical staff, HDR brachytherapy should be explored. To enhance the role of this therapy in treatment of head and neck lesions, we have reviewed its outcomes with oral cancer, including Phase I/II to Phase III studies, evaluating this technique in terms of safety and efficacy. In particular, our studies have shown that superficial tumors can be treated using a non-invasive mold technique on an outpatient basis without adverse reactions. The next generation of image-guided brachytherapy using HDR has been discussed. In conclusion, although concrete evidence is yet to be produced with a sophisticated study in a reproducible manner, HDR brachytherapy remains an important option for treatment of oral cancer.

  5. Physics of vascular brachytherapy.

    PubMed

    Jani, S K

    1999-08-01

    Basic physics plays an important role in understanding the clinical utility of radioisotopes in brachytherapy. Vascular brachytherapy is a very unique application of localized radiation in that dose levels very close to the source are employed to treat tissues within the arterial wall. This article covers basic physics of radioactivity and differentiates between beta and gamma radiations. Physical parameters such as activity, half-life, exposure and absorbed dose have been explained. Finally, the dose distribution around a point source and a linear source is described. The principles of basic physics are likely to play an important role in shaping the emerging technology and its application in vascular brachytherapy.

  6. Cylinder To Cylinder Balancing Using Intake Valve Actuation

    DOEpatents

    Duffy, Kevin P.; Kieser, Andrew J.; Kilkenny, Jonathan P.

    2005-01-18

    A method and apparatus for balancing a combustion phasing between a plurality of cylinders located in an engine. The method and apparatus includes a determining a combustion timing in each cylinder, establishing a baseline parameter for a desired combustion timing, and varying actuation of at least one of a plurality of intake valves, each intake valve being in fluid communication with a corresponding cylinder, such that the combustion timing in each cylinder is substantially equal to the desired combustion timing.

  7. Emphysematous vaginitis.

    PubMed

    Lima-Silva, Joana; Vieira-Baptista, Pedro; Cavaco-Gomes, João; Maia, Tiago; Beires, Jorge

    2015-04-01

    Emphysematous vaginitis is a rare condition, characterized by the presence of multiple gas-filled cysts in the vaginal and/or exocervical mucosa. Although its etiology is not completely understood, it is self-limited, with a benign clinical course. Vaginal discharge, sometimes bloody, and pruritus are the most common symptoms. Chronic and acute inflammation can be found, and diseases that impair the immune system and pregnancy have been associated with this condition. A 48-year-old postmenopausal woman, with a history of hysterectomy with several comorbidities, presented with a 4-month history of bloody discharge and vulvar pruritus. Examination showed multiple cystic lesions, 1 to 5 mm, occupying the posterior and right lateral vaginal walls. Speculum examination produced crepitus. Vaginal wet mount was normal, except for diminished lactobacilli; results of Trichomonas vaginalis DNA test and vaginal cultures were negative. Lugol's iodine applied to the vagina was taken up by the intact lesions. Biopsy result showed typical features of emphysematous vaginitis. This is an unusual entity, presenting with common gynecological complaints, and both physicians and pathologists should be aware to prevent misdiagnosis and overtreatment.

  8. High dose rate brachytherapy for oral cancer

    PubMed Central

    YamazakI, Hideya; Yoshida, Ken; Yoshioka, Yasuo; Shimizutani, Kimishige; Furukawa, Souhei; Koizumi, Masahiko; Ogawa, Kazuhiko

    2013-01-01

    Brachytherapy results in better dose distribution compared with other treatments because of steep dose reduction in the surrounding normal tissues. Excellent local control rates and acceptable side effects have been demonstrated with brachytherapy as a sole treatment modality, a postoperative method, and a method of reirradiation. Low-dose-rate (LDR) brachytherapy has been employed worldwide for its superior outcome. With the advent of technology, high-dose-rate (HDR) brachytherapy has enabled health care providers to avoid radiation exposure. This therapy has been used for treating many types of cancer such as gynecological cancer, breast cancer, and prostate cancer. However, LDR and pulsed-dose-rate interstitial brachytherapies have been mainstays for head and neck cancer. HDR brachytherapy has not become widely used in the radiotherapy community for treating head and neck cancer because of lack of experience and biological concerns. On the other hand, because HDR brachytherapy is less time-consuming, treatment can occasionally be administered on an outpatient basis. For the convenience and safety of patients and medical staff, HDR brachytherapy should be explored. To enhance the role of this therapy in treatment of head and neck lesions, we have reviewed its outcomes with oral cancer, including Phase I/II to Phase III studies, evaluating this technique in terms of safety and efficacy. In particular, our studies have shown that superficial tumors can be treated using a non-invasive mold technique on an outpatient basis without adverse reactions. The next generation of image-guided brachytherapy using HDR has been discussed. In conclusion, although concrete evidence is yet to be produced with a sophisticated study in a reproducible manner, HDR brachytherapy remains an important option for treatment of oral cancer. PMID:23179377

  9. 10 CFR 35.406 - Brachytherapy sources accountability.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... 10 Energy 1 2010-01-01 2010-01-01 false Brachytherapy sources accountability. 35.406 Section 35....406 Brachytherapy sources accountability. (a) A licensee shall maintain accountability at all times... area. (c) A licensee shall maintain a record of the brachytherapy source accountability in accordance...

  10. SU-F-T-25: Design and Implementation of a Multi-Purpose Applicator for Pelvic Brachytherapy Applications

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Bogue, J; Parsai, E

    Purpose: The current generation of inflatable multichannel brachytherapy applicators, such as the Varian Capri, have limited implementation to only vaginal and rectal cancers. While there are similar designs utilizing rigid, non-inflatable applicators, these alternatives could cause increased dose to surrounding tissue due to air gaps. Modification of the Capri could allow for easier treatment planning by reducing the number of channels and increased versatility by modifying the applicator to include an attachable single tandem for cervical or multiple tandems for endometrial applications. Methods: A Varian Capri applicator was simulated in water to replicate a patient. Multiple plans were optimized tomore » deliver a prescribed dose of 100 cGy at 5mm away from the exterior of the applicator using six to thirteen existing channels. The current model was expanded upon to include a detachable tandem or multiple tandoms to increase its functionality to both cervical and endometrial cancers. Models were constructed in both threedimensional rendering software and Monte Carlo to allow prototyping and simulations. Results: Treatment plans utilizing six to thirteen channels produced limited dosimetric differences between channel arrangements, with a seven channel plan very closely approximating the thirteen channels. It was concluded that only seven channels would be necessary in future simulations to give an accurate representation of the applicator. Tandem attachments were prototyped for the applicator to demonstrate the ease of which they could be included. Future simulation in treatment planning software and Monte Carlo results will be presented to further define the ideal applicator geometry Conclusion: The current Capri applicator design could be easily modified to increase applicability to include cervical and endometrial treatments in addition to vaginal and rectal cancers. This new design helps in a more versatile single use applicator that can easily be

  11. Complete response in a patient with gynecological hidradenocarcinoma treated with exclusive external beam radiotherapy and brachytherapy: a case report

    PubMed Central

    Giannelli, Flavio; Chiola, Ilaria; Garelli, Stefania; Pastorino, Alice; Marcenaro, Michela; Mammoliti, Serafina; Costantini, Sergio; Bizzarri, Nicolò; Vellone, Valerio; Barra, Salvina; Corvò, Renzo

    2017-01-01

    Hidradenocarcinoma (HC) is a very rare disease. This case report illustrates a successful treatment of a 60-year-old woman with vulvo-vaginal localization of hidradenocarcinoma treated with external beam radiotherapy delivered by helical tomotherapy with a simultaneous integrated boost (SIB), followed by brachytherapy. External beam radiotherapy dose prescription was 50.4 Gy in 28 fractions, five fractions per week to whole pelvis (planning target volume 1 – PTV1), 60.2 Gy in 28 fractions to SIB1 (fundus of uterus and right inguinal node), and 58.8 Gy in 28 fractions to SIB2 (lower/middle third of vagina, paraurethral region and right inguinal lymph nodes). Brachytherapy dose prescription was 28 Gy in 4 fractions for cervix, fundus of uterus and upper third of vagina (HR-CTV1), and 22 Gy in 4 fractions to middle third of vagina and paraurethral region (HR-CTV2). D90 for whole treatment was 91.9 Gy and 86.0 Gy for HR-CTV1 and HR-CTV2, respectively. Patient remained 12-months disease-free without treatment related side effects. PMID:29441103

  12. Complete response in a patient with gynecological hidradenocarcinoma treated with exclusive external beam radiotherapy and brachytherapy: a case report.

    PubMed

    Giannelli, Flavio; Chiola, Ilaria; Belgioia, Liliana; Garelli, Stefania; Pastorino, Alice; Marcenaro, Michela; Mammoliti, Serafina; Costantini, Sergio; Bizzarri, Nicolò; Vellone, Valerio; Barra, Salvina; Corvò, Renzo

    2017-12-01

    Hidradenocarcinoma (HC) is a very rare disease. This case report illustrates a successful treatment of a 60-year-old woman with vulvo-vaginal localization of hidradenocarcinoma treated with external beam radiotherapy delivered by helical tomotherapy with a simultaneous integrated boost (SIB), followed by brachytherapy. External beam radiotherapy dose prescription was 50.4 Gy in 28 fractions, five fractions per week to whole pelvis (planning target volume 1 - PTV1), 60.2 Gy in 28 fractions to SIB1 (fundus of uterus and right inguinal node), and 58.8 Gy in 28 fractions to SIB2 (lower/middle third of vagina, paraurethral region and right inguinal lymph nodes). Brachytherapy dose prescription was 28 Gy in 4 fractions for cervix, fundus of uterus and upper third of vagina (HR-CTV1), and 22 Gy in 4 fractions to middle third of vagina and paraurethral region (HR-CTV2). D 90 for whole treatment was 91.9 Gy and 86.0 Gy for HR-CTV1 and HR-CTV2, respectively. Patient remained 12-months disease-free without treatment related side effects.

  13. Brachytherapy

    MedlinePlus

    ... care for brachytherapy catheters. top of page What equipment is used? For permanent implants, radioactive material (which ... the tumor. top of page Who operates the equipment? The equipment is operated by a medical physicist, ...

  14. Vaginal Cancer Overview

    MedlinePlus

    ... are here Home > Types of Cancer > Vaginal Cancer Vaginal Cancer This is Cancer.Net’s Guide to Vaginal Cancer. Use the menu below to choose the ... social workers, and patient advocates. Cancer.Net Guide Vaginal Cancer Introduction Statistics Medical Illustrations Risk Factors and ...

  15. Vaginal Microbiomes Associated With Aerobic Vaginitis and Bacterial Vaginosis.

    PubMed

    Kaambo, Evelyn; Africa, Charlene; Chambuso, Ramadhani; Passmore, Jo-Ann Shelley

    2018-01-01

    A healthy vaginal microbiota is considered to be significant for maintaining vaginal health and preventing infections. However, certain vaginal bacterial commensal species serve an important first line of defense of the body. Any disruption of this microbial barrier might result in a number of urogenital conditions including aerobic vaginitis (AV) and bacterial vaginosis (BV). The health of the vagina is closely associated with inhabitant microbiota. Furthermore, these microbes maintain a low vaginal pH, prevent the acquisition of pathogens, stimulate or moderate the local innate immune system, and further protect against complications during pregnancies. Therefore, this review will focus on vaginal microbial "health" in the lower reproductive tract of women and on the physiological characteristics that determine the well-being of reproductive health. In addition, we explore the distinct versus shared characteristics of BV and AV, which are commonly associated with increased risk for preterm delivery.

  16. Vaginal Microbiomes Associated With Aerobic Vaginitis and Bacterial Vaginosis

    PubMed Central

    Kaambo, Evelyn; Africa, Charlene; Chambuso, Ramadhani; Passmore, Jo-Ann Shelley

    2018-01-01

    A healthy vaginal microbiota is considered to be significant for maintaining vaginal health and preventing infections. However, certain vaginal bacterial commensal species serve an important first line of defense of the body. Any disruption of this microbial barrier might result in a number of urogenital conditions including aerobic vaginitis (AV) and bacterial vaginosis (BV). The health of the vagina is closely associated with inhabitant microbiota. Furthermore, these microbes maintain a low vaginal pH, prevent the acquisition of pathogens, stimulate or moderate the local innate immune system, and further protect against complications during pregnancies. Therefore, this review will focus on vaginal microbial “health” in the lower reproductive tract of women and on the physiological characteristics that determine the well-being of reproductive health. In addition, we explore the distinct versus shared characteristics of BV and AV, which are commonly associated with increased risk for preterm delivery. PMID:29632854

  17. A retrospective analysis of rectal and bladder dose for gynecological brachytherapy treatments with GZP6 HDR afterloading system

    PubMed Central

    Bahreyni Toossi, Mohammad Taghi; Ghorbani, Mahdi; Makhdoumi, Yasha; Taheri, Mojtaba; Homaee Shandiz, Fatemeh; Zahed Anaraki, Siavash; Soleimani Meigooni, Ali

    2012-01-01

    Aim The aim of this work is to evaluate rectal and bladder dose for the patients treated for gynecological cancers. Background The GZP6 high dose rate brachytherapy system has been recently introduced to a number of radiation therapy departments in Iran, for treatment of various tumor sites such as cervix and vagina. Materials and methods Our analysis was based on dose measurements for 40 insertions in 28 patients, treated by a GZP6 unit between June 2009 and November 2010. Treatments consisted of combined teletherapy and intracavitary brachytherapy. In vivo dosimetry was performed with TLD-400 chips and TLD-100 microcubes in the rectum and bladder. Results The average of maximum rectal and bladder dose values were found to be 7.62 Gy (range 1.72–18.55 Gy) and 5.17 Gy (range 0.72–15.85 Gy), respectively. It has been recommended by the ICRU that the maximum dose to the rectum and bladder in intracavitary treatment of vaginal or cervical cancer should be lower than 80% of the prescribed dose to point A in the Manchester system. In this study, of the total number of 40 insertions, maximum rectal dose in 29 insertions (72.5% of treatment sessions) and maximum bladder dose in 18 insertions (45% of treatments sessions) were higher than 80% of the prescribed dose to the point of dose prescription. Conclusion In vivo dosimetry for patients undergoing treatment by GZP6 brachytherapy system can be used for evaluation of the quality of brachytherapy treatments by this system. This information could be used as a base for developing the strategy for treatment of patients treated with GZP6 system. PMID:24377037

  18. Treatment of postmenopausal vaginal atrophy with 10-μg estradiol vaginal tablets.

    PubMed

    Panay, Nick; Maamari, Ricardo

    2012-03-01

    Postmenopausal estrogen deficiency can lead to symptoms of urogenital atrophy. Individuals with urogenital atrophy have symptoms that include vaginal dryness, vaginal and vulval irritation, vaginal soreness, pain and burning during urination (dysuria), increased vaginal discharge, vaginal odour, vaginal infections, recurrent urinary tract infections, pain associated with sexual activity (dyspareunia) and vaginal bleeding associated with sexual activity. Despite the frequency and effects of vaginal atrophy symptoms, they are often under-reported and, consequently, under-treated. Therefore, care of a menopausal woman should include a physical assessment of vaginal atrophy and a dialogue between the physician and the patient that explores existing symptoms and their effect on vulvovaginal health, sexuality and quality-of-life issues. The development of the ultra-low-dose 10-µg estradiol vaginal tablets is in line with the requirements of regulatory agencies and women's health societies regarding the use of the lowest effective hormonal dose. Because of its effectiveness and safety profiles, in addition to its minimal systemic absorption, the 10-µg estradiol vaginal tablet can offer greater reassurance to health-care providers and postmenopausal women with an annual estradiol administration of only 1.14 mg.

  19. Premenarchal, recurrent vaginal discharge associated with an incomplete obstructing longitudinal vaginal septum.

    PubMed

    Hansen, Keith A; DeWitt, Jason

    2005-12-01

    To describe an unusual, premenarchal presentation of an obstructive vaginal anomaly. Case Report. University Medical Center. Premenarchal subject Vaginogram, vaginal septum resection. Vaginal septum resection with resolution of vaginal discharge. This case demonstrates some of the typical features of uterus didelphys bicollis with incomplete obstructing hemivagina, but had a unique presentation with premenarchal, recurrent vaginal discharge. Typically, patients with an obstructing mullerian anomaly present after menarche with pelvic pain and a mass. The vaginogram assists in the preoperative definition of abnormal anatomy which allows the surgeon to develop the most appropriate surgical approach. Resection of this incompletely obstructing vaginal septum resulted in resolution of the recurrent vaginal discharge.

  20. SU-D-19A-05: The Dosimetric Impact of Using Xoft Axxent® Electronic Brachytherapy Source TG-43 Dosimetry Parameters for Treatment with the Xoft 30 Mm Diameter Vaginal Applicator

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Simiele, S; Micka, J; Culberson, W

    2014-06-01

    Purpose: A full TG-43 dosimetric characterization has not been performed for the Xoft Axxent ® electronic brachytherapy source (Xoft, a subsidiary of iCAD, San Jose, CA) within the Xoft 30 mm diameter vaginal applicator. Currently, dose calculations are performed using the bare-source TG-43 parameters and do not account for the presence of the applicator. This work focuses on determining the difference between the bare-source and sourcein- applicator TG-43 parameters. Both the radial dose function (RDF) and polar anisotropy function (PAF) were computationally determined for the source-in-applicator and bare-source models to determine the impact of using the bare-source dosimetry data. Methods:more » MCNP5 was used to model the source and the Xoft 30 mm diameter vaginal applicator. All simulations were performed using 0.84p and 0.03e cross section libraries. All models were developed based on specifications provided by Xoft. The applicator is made of a proprietary polymer material and simulations were performed using the most conservative chemical composition. An F6 collision-kerma tally was used to determine the RDF and PAF values in water at various dwell positions. The RDF values were normalized to 2.0 cm from the source to accommodate the applicator radius. Source-in-applicator results were compared with bare-source results from this work as well as published baresource results. Results: For a 0 mm source pullback distance, the updated bare-source model and source-in-applicator RDF values differ by 2% at 3 cm and 4% at 5 cm. The largest PAF disagreements were observed at the distal end of the source and applicator with up to 17% disagreement at 2 cm and 8% at 8 cm. The bare-source model had RDF values within 2.6% of the published TG-43 data and PAF results within 7.2% at 2 cm. Conclusion: Results indicate that notable differences exist between the bare-source and source-in-applicator TG-43 simulated parameters. Xoft Inc. provided partial funding for this work.« less

  1. Hysterectomy - vaginal - discharge

    MedlinePlus

    Vaginal hysterectomy - discharge; Laparoscopically assisted vaginal hysterectomy - discharge; LAVH - discharge ... you were in the hospital, you had a vaginal hysterectomy. Your surgeon made a cut in your ...

  2. MO-E-BRD-03: Intra-Operative Breast Brachytherapy: Is One Stop Shopping Best? [Non-invasive Image-Guided Breast Brachytherapy

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Libby, B.

    2015-06-15

    Is Non-invasive Image-Guided Breast Brachytherapy Good? – Jess Hiatt, MS Non-invasive Image-Guided Breast Brachytherapy (NIBB) is an emerging therapy for breast boost treatments as well as Accelerated Partial Breast Irradiation (APBI) using HDR surface breast brachytherapy. NIBB allows for smaller treatment volumes while maintaining optimal target coverage. Considering the real-time image-guidance and immobilization provided by the NIBB modality, minimal margins around the target tissue are necessary. Accelerated Partial Breast Irradiation in brachytherapy: is shorter better? - Dorin Todor, PhD VCU A review of balloon and strut devices will be provided together with the origins of APBI: the interstitial multi-catheter implant.more » A dosimetric and radiobiological perspective will help point out the evolution in breast brachytherapy, both in terms of devices and the protocols/clinical trials under which these devices are used. Improvements in imaging, delivery modalities and convenience are among the factors driving the ultrashort fractionation schedules but our understanding of both local control and toxicities associated with various treatments is lagging. A comparison between various schedules, from a radiobiological perspective, will be given together with a critical analysis of the issues. to review and understand the evolution and development of APBI using brachytherapy methods to understand the basis and limitations of radio-biological ‘equivalence’ between fractionation schedules to review commonly used and proposed fractionation schedules Intra-operative breast brachytherapy: Is one stop shopping best?- Bruce Libby, PhD. University of Virginia A review of intraoperative breast brachytherapy will be presented, including the Targit-A and other trials that have used electronic brachytherapy. More modern approaches, in which the lumpectomy procedure is integrated into an APBI workflow, will also be discussed. Learning Objectives: To review past and

  3. Vaginal foreign bodies.

    PubMed

    Stricker, T; Navratil, F; Sennhauser, F H

    2004-04-01

    To evaluate the clinical features and outcome in girls with a vaginal foreign body. Retrospective review of medical records of 35 girls with a vaginal foreign body seen in an outpatient clinic for paediatric and adolescent gynaecology between 1980 and 2000. The ages ranged from 2.6 to 9.2 years. The most common symptom was blood-stained vaginal discharge/vaginal bleeding (49%). Duration of symptoms varied from 1 day to 2 years. Fifty-four percent of the patients recalled insertion of the foreign object, usually by the girl herself. All but three patients (91%) either recalled insertion of the foreign object and/or had vaginal bleeding or blood-stained or foul-smelling vaginal discharge, and/or visualization or palpation of the foreign body in physical examination. Symptoms resolved after removal of the foreign body followed by a single irrigation with Providon-Iod (Betadine). In the majority of patients a carefully obtained history and physical examination suggest the diagnosis of a vaginal foreign object. The leading symptoms are vaginal bleeding and blood-stained or foul smelling vaginal discharge. Removal of the foreign object followed by a single irrigation with Providon-Iod is the definitive treatment and does not require additional measures.

  4. State-of-the-art: prostate LDR brachytherapy.

    PubMed

    Voulgaris, S; Nobes, J P; Laing, R W; Langley, S E M

    2008-01-01

    This article on low dose rate (LDR) prostate brachytherapy reviews long-term results, patient selection and quality of life issues. Mature results from the United States and United Kingdom are reported and issues regarding definitions of biochemical failure are discussed. Latest data comparing brachytherapy with radical prostatectomy or no definitive treatment and also the risk of secondary malignancies after prostate brachytherapy are presented. Urological parameters of patient selection and quality of life issues concerning urinary, sexual and bowel function are reviewed. The position of prostate brachytherapy next to surgery as a first-line treatment modality is demonstrated.

  5. Clinical characteristics of aerobic vaginitis and its association to vaginal candidiasis, trichomonas vaginitis and bacterial vaginosis.

    PubMed

    Jahic, Mahira; Mulavdic, Mirsada; Nurkic, Jasmina; Jahic, Elmir; Nurkic, Midhat

    2013-12-01

    Examine clinical characteristics of aerobic vaginitis and mixed infection for the purpose of better diagnostic accuracy and treatment efficiency. Prospective research has been conducted at Clinic for Gynecology and Obstetrics, Department for Microbiology and Pathology at Polyclinic for laboratory diagnostic and Gynecology and Obstetrics Department at Health Center Sapna. Examination included 100 examinees with the signs of vaginitis. anamnesis, clinical, gynecological and microbiological examination of vaginal smear. The average age of the examinees was 32,62±2,6. Examining vaginal smears of the examinees with signs of vaginitis in 96% (N-96) different microorganisms have been isolated, while in 4% (N-4) findings were normal. AV has been found in 51% (N-51) of the examinees, Candida albicans in 17% (N-17), BV in 15% (N-15), Trichomonas vaginalis in 13% (N-13). In 21% (N-21) AV was diagnosed alone while associated with other agents in 30% (N-30). Most common causes of AV are E. coli (N-55) and E. faecalis (N-52). AV and Candida albicanis have been found in (13/30, 43%), Trichomonas vaginalis in (9/30, 30%) and BV (8/30, 26%). Vaginal secretion is in 70,05% (N-36) yellow coloured, red vagina wall is recorded in 31,13% (N-16) and pruritus in 72,54% (N-37). Increased pH value of vagina found in 94,10% (N-48). The average pH value of vaginal environment was 5,15±0,54 and in associated presence of AV and VVC, TV and BV was 5,29±0,56 which is higher value considering presence of AV alone but that is not statistically significant difference (p>0,05). Amino-odor test was positive in 29,94% (N-15) of associated infections. Lactobacilli are absent, while leukocytes are increased in 100% (N-51) of the examinees with AV. AV is vaginal infection similar to other vaginal infections. It is important to be careful while diagnosing because the treatment of AV differentiates from treatment of other vaginitis.

  6. Value of bacterial culture of vaginal swabs in diagnosis of vaginal infections.

    PubMed

    Nenadić, Dane; Pavlović, Miloš D

    2015-06-01

    Vaginal and cervical swab culture is still very common procedure in our country's everyday practice whereas simple and rapid diagnostic methods have been very rarely used. The aim of this study was to show that the employment of simple and rapid diagnostic tools [vaginal fluid wet mount microscopy (VFWMM), vaginal pH and potassium hydroxide (KOH) test] offers better assessment of vaginal environment than standard microbiologic culture commonly used in Serbia. This prospective study included 505 asymptomatic pregnant women undergoing VFWMM, test with 10% KOH, determination of vaginal pH and standard culture of cervicovaginal swabs. Combining findings from the procedures was used to make diagnoses of bacterial vaginosis (BV) and vaginitis. In addition, the number of polymorphonuclear leukocytes (PMN) was determined in each sample and analyzed along with other findings. Infections with Candida albicans and Trichomonas vaginalis were confirmed or excluded by microscopic examination. In 36 (6%) patients cervicovaginal swab cultures retrieved several aerobes and facultative anaerobes, whereas in 52 (11%) women Candida albicans was isolated. Based on VFWMM findings and clinical criteria 96 (19%) women had BV, 19 (4%) vaginitis, and 72 (14%) candidiasis. Of 115 women with BV and vaginitis, pH 4.5 was found in 5, and of 390 with normal findings 83 (21%) had vaginal pH 4.5. Elevated numbers of PMN were found in 154 (30%) women--in 83 (54%) of them VFWMM was normal. Specificity and sensitivity of KOH test and vaginal pH determination in defining pathological vaginal flora were 95% and 81%, and 79% and 91%, respectively. Cervicovaginal swab culture is expensive but almost non-informative test in clinical practice. The use of simpler and rapid methods as vaginal fluid wet mount microscopy, KOH test and vaginal pH offers better results in diagnosis, and probably in the treatment and prevention of sequels of vaginal infections.

  7. Quick release engine cylinder

    DOEpatents

    Sunnarborg, Duane A.

    2000-01-01

    A quick release engine cylinder allows optical access to an essentially unaltered combustion chamber, is suitable for use with actual combustion processes, and is amenable to rapid and repeated disassembly and cleaning. A cylinder member, adapted to constrain a piston to a defined path through the cylinder member, sealingly engages a cylinder head to provide a production-like combustion chamber. A support member mounts with the cylinder member. The support-to-cylinder mounting allows two relationships therebetween. In the first mounting relationship, the support engages the cylinder member and restrains the cylinder against the head. In the second mounting relationship, the cylinder member can pass through the support member, moving away from the head and providing access to the piston-top and head.

  8. Cylinder Test Specification

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Richard Catanach; Larry Hill; Herbert Harry

    1999-10-01

    The purpose of the cylinder testis two-fold: (1) to characterize the metal-pushing ability of an explosive relative to that of other explosives as evaluated by the E{sub 19} cylinder energy and the G{sub 19} Gurney energy and (2) to help establish the explosive product equation-of-state (historically, the Jones-Wilkins-Lee (JWL) equation). This specification details the material requirements and procedures necessary to assemble and fire a typical Los Alamos National Laboratory (LANL) cylinder test. Strict adherence to the cylinder. material properties, machining tolerances, material heat-treatment and etching processes, and high explosive machining tolerances is essential for test-to-test consistency and to maximize radialmore » wall expansions. Assembly and setup of the cylinder test require precise attention to detail, especially when placing intricate pin wires on the cylinder wall. The cylinder test is typically fired outdoors and at ambient temperature.« less

  9. Vaginal yeast infection

    MedlinePlus

    Yeast infection - vagina; Vaginal candidiasis; Monilial vaginitis ... Most women have a vaginal yeast infection at some time. Candida albicans is a common type of fungus. It is often found in small amounts in the ...

  10. Fracture mechanics analysis of NGV fuel cylinders. Part 1: Steel cylinders

    NASA Astrophysics Data System (ADS)

    Connolly, M. P.; Hudak, S. J.; Roy, S.

    1993-02-01

    Compressed natural gas (CNG) cylinders for natural gas vehicles (NGVs) are subject to a combination of pressure cycles, associated with periodic refueling, and a potentially corrosive CNG environment. Under these conditions it has been shown that the life of the cylinder is governed by the corrosion-fatigue crack growth of internal flaws such as voids, pits or folds that may be present after manufacture. For NGV applications, these cylinders are required to operate for at least 15 years and the report, through a detailed fracture mechanics analysis, describes approaches to achieving the desired life. The analysis shows that a 15 year cylinder life can be obtained by using quality control to ensure that no initial defects greater than 0.045 in. X 0.090 in. exist after manufacture. Alternatively, gas drying can be used at the distribution stations to reduce the detrimental effects of the remaining CNG impurities, and thereby, produce long cylinder lives. The analysis also considers the role of in-service inspection/retest and shows that in-service NDE has little advantage, either technically or economically, for ensuring the fitness-for-service of steel NGV cylinders. The analysis also shows that hydrostatic testing of cylinders, either at manufacture or in service, is ineffective for detecting fatigue cracks and therefore should not be implemented as part of a fitness-for-service plan for NGV fuel cylinders. The issue of cylinder geometry was also considered and the analysis shows that improperly designed flat-bottomed CNG cylinders can result in premature fatigue failures originating at the inner wall in the transition region between the cylinder end and sidewall.

  11. Bladder–Rectum Spacer Balloon in High-Dose-Rate Brachytherapy in Cervix Carcinoma

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Rai, Bhavana; Patel, Firuza D., E-mail: firuzapatel@gmail.com; Chakraborty, Santam

    2013-04-01

    Purpose: To compare bladder and rectum doses with the use of a bladder–rectum spacer balloon (BRSB) versus standard gauze packing in the same patient receiving 2 high-dose-rate intracavitary brachytherapy fractions. Methods and Materials: This was a randomized study to compare the reduction in bladder and rectum doses with the use of a BRSB compared with standard gauze packing in patients with carcinoma of the cervix being treated with high-dose-rate intracavitary brachytherapy. The patients were randomized between 2 arms. In arm A, vaginal packing was done with standard gauze packing in the first application, and BRSB was used in the secondmore » application. Arm B was the reverse of arm A. The International Commission for Radiation Units and Measurement (ICRU) point doses and doses to 0.1-cm{sup 3}, 1-cm{sup 3}, 2-cm{sup 3}, 5-cm{sup 3}, and 10-cm{sup 3} volumes of bladder and rectum were compared. The patients were also subjectively assessed for the ease of application and the time taken for application. Statistical analysis was done using the paired t test. Results: A total of 43 patients were enrolled; however, 3 patients had to be excluded because the BRSB could not be inserted owing to unfavorable local anatomy. Thus 40 patients (80 plans) were evaluated. The application was difficult in 3 patients with BRSB, and in 2 patients with BRSB the application time was prolonged. There was no significant difference in bladder doses to 0.1 cm{sup 3}, 1 cm{sup 3}, 2 cm{sup 3}, 5 cm{sup 3}, and 10 cm{sup 3} and ICRU bladder point. Statistically significant dose reductions to 0.1-cm{sup 3}, 1-cm{sup 3}, and 2-cm{sup 3} volumes for rectum were observed with the BRSB. No significant differences in 5-cm{sup 3} and 10-cm{sup 3} volumes and ICRU rectum point were observed. Conclusion: A statistically significant dose reduction was observed for small high-dose volumes in rectum with the BRSB. The doses to bladder were comparable for BRSB and gauze packing. Transparent

  12. The dosimetry of brachytherapy-induced erectile dysfunction

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Merrick, Gregory S.; Butler, Wayne M

    2003-12-31

    There is emerging evidence that brachytherapy-induced erectile dysfunction (ED) is technique-related and may be minimized by careful attention to source placement. Herein, we review the relationship between radiation doses to the prostate gland/surrounding structures and the development of brachytherapy-induced ED. The permanent prostate brachytherapy literature was reviewed using MEDLINE searches to ensure completeness. Although the site-specific structure associated with brachytherapy-induced ED remains unknown, there is an increasing body of data implicating the proximal penis. With day 0 CT-based dosimetry, the dose to 50% (D{sub 50}) and 25% (D{sub 25}) of the bulb of the penis should be maintained below 40%more » and 60% mPD, respectively, while the crura D{sub 50} should be maintained below 28% mPD to maximize post-brachytherapy potency. To date, there is no data to suggest that either radiation doses to the neurovascular bundles or choice of isotope is associated with brachytherapy-induced ED, while conflicting data has been reported regarding radiation dose to the prostate and the use of supplemental external beam radiation therapy. Although the etiology of brachytherapy-induced ED is likely multifactorial, the available data supports the proximal penis as an important site-specific structure. Refinements in implant technique, including preplanning and intraoperative seed placement, will result in lower radiation doses to the proximal penis with potential improvement in potency preservation.« less

  13. Clinical Characteristics of Aerobic Vaginitis and Its Association to Vaginal Candidiasis, Trichomonas Vaginitis and Bacterial Vaginosis

    PubMed Central

    Jahic, Mahira; Mulavdic, Mirsada; Nurkic, Jasmina; Jahic, Elmir; Nurkic, Midhat

    2013-01-01

    ABSTRACT Aim of the work: Examine clinical characteristics of aerobic vaginitis and mixed infection for the purpose of better diagnostic accuracy and treatment efficiency. Materials and methods: Prospective research has been conducted at Clinic for Gynecology and Obstetrics, Department for Microbiology and Pathology at Polyclinic for laboratory diagnostic and Gynecology and Obstetrics Department at Health Center Sapna. Examination included 100 examinees with the signs of vaginitis. Examination consisted of: anamnesis, clinical, gynecological and microbiological examination of vaginal smear. Results: The average age of the examinees was 32,62±2,6. Examining vaginal smears of the examinees with signs of vaginitis in 96% (N-96) different microorganisms have been isolated, while in 4% (N-4) findings were normal. AV has been found in 51% (N-51) of the examinees, Candida albicans in 17% (N-17), BV in 15% (N-15), Trichomonas vaginalis in 13% (N-13). In 21% (N-21) AV was diagnosed alone while associated with other agents in 30% (N-30). Most common causes of AV are E. coli (N-55) and E. faecalis (N-52). AV and Candida albicanis have been found in (13/30, 43%), Trichomonas vaginalis in (9/30, 30%) and BV (8/30, 26%). Vaginal secretion is in 70,05% (N-36) yellow coloured, red vagina wall is recorded in 31,13% (N-16) and pruritus in 72,54% (N-37). Increased pH value of vagina found in 94,10% (N-48). The average pH value of vaginal environment was 5,15±0,54 and in associated presence of AV and VVC, TV and BV was 5,29±0,56 which is higher value considering presence of AV alone but that is not statistically significant difference (p>0,05). Amino-odor test was positive in 29,94% (N-15) of associated infections. Lactobacilli are absent, while leukocytes are increased in 100% (N-51) of the examinees with AV. Conclusion: AV is vaginal infection similar to other vaginal infections. It is important to be careful while diagnosing because the treatment of AV differentiates from

  14. MO-B-BRC-01: Introduction [Brachytherapy

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Prisciandaro, J.

    2016-06-15

    Brachytherapy has proven to be an effective treatment option for prostate cancer. Initially, prostate brachytherapy was delivered through permanently implanted low dose rate (LDR) radioactive sources; however, high dose rate (HDR) temporary brachytherapy for prostate cancer is gaining popularity. Needle insertion during prostate brachytherapy is most commonly performed under ultrasound (U/S) guidance; however, treatment planning may be performed utilizing several imaging modalities either in an intra- or post-operative setting. During intra-operative prostate HDR, the needles are imaged during implantation, and planning may be performed in real time. At present, the most common imaging modality utilized for intra-operative prostate HDR ismore » U/S. Alternatively, in the post-operative setting, following needle implantation, patients may be simulated with computed tomography (CT) or magnetic resonance imaging (MRI). Each imaging modality and workflow provides its share of benefits and limitations. Prostate HDR has been adopted in a number of cancer centers across the nation. In this educational session, we will explore the role of U/S, CT, and MRI in HDR prostate brachytherapy. Example workflows and operational details will be shared, and we will discuss how to establish a prostate HDR program in a clinical setting. Learning Objectives: Review prostate HDR techniques based on the imaging modality Discuss the challenges and pitfalls introduced by the three imagebased options for prostate HDR brachytherapy Review the QA process and learn about the development of clinical workflows for these imaging options at different institutions.« less

  15. Yeast Infection (Vaginal)

    MedlinePlus

    Yeast infection (vaginal) Overview A vaginal yeast infection is a fungal infection that causes irritation, discharge and intense itchiness ... symptoms Causes The fungus candida causes a vaginal yeast infection. Your vagina naturally contains a balanced mix of yeast, including ...

  16. Place of modern imaging in brachytherapy planning.

    PubMed

    Hellebust, T P

    2018-06-01

    Imaging has probably been the most important driving force for the development of brachytherapy treatments the last 20 years. Due to implementation of three-dimensional imaging, brachytherapy is nowadays a highly accurate and reliable treatment option for many cancer patients. To be able to optimize the dose distribution in brachytherapy the anatomy and the applicator(s) or sources should be correctly localised in the images. For computed tomography (CT) the later criteria is easily fulfilled for most brachytherapy sites. However, for many sites, like cervix and prostate, CT is not optimal for delineation since soft tissue is not adequately visualized and the tumor is not well discriminated. For cervical cancer treatment planning based on magnetic resonance imaging (MRI) is recommended. Some centres also use MRI for postimplant dosimetry of permanent prostate seed implant and high dose rate prostate brachytherapy. Moreover, in so called focal brachytherapy where only a part of the prostate is treated, multiparametric MRI is an excellent tool that can assist in defining the target volume. Applicator or source localization is challenging using MRI, but tolls exist to assist this process. Also, geometrical distortions should be corrected or accounted for. Transrectal ultrasound is considered to be the gold standard for high dose rate prostate brachytherapy and transrectal ultrasound -based brachytherapy procedure offers a method for interactive treatment planning. Reconstruction of the needles is sometimes challenging, especially to identify the needle tip. The accuracy of the reconstruction could be improved by measuring the residuals needle length and by using a bi-planar transducer. The last decade several groups worldwide have explored the use of transrectal and transabdominal ultrasound for cervical cancer brachytherapy. Since ultrasonography is widely available, offers fast image acquisition and is a rather inexpensive modality such development is interesting

  17. Protection against rat vaginal candidiasis by adoptive transfer of vaginal B lymphocytes.

    PubMed

    De Bernardis, Flavia; Santoni, Giorgio; Boccanera, Maria; Lucciarini, Roberta; Arancia, Silvia; Sandini, Silvia; Amantini, Consuelo; Cassone, Antonio

    2010-06-01

    Vulvovaginal candidiasis is a mucosal infection affecting many women, but the immune mechanisms operating against Candida albicans at the mucosal level remain unknown. A rat model was employed to further characterize the contribution of B and T cells to anti-Candida vaginal protection. Particularly, the protective role of vaginal B cells was studied by means of adoptive transfer of vaginal CD3(-) CD5(+) IgM(+) cells from Candida-immunized rats to naïve animals. This passive transfer of B cells resulted into a number of vaginal C. albicans CFU approximately 50% lower than their controls. Sorted CD3(-) CD5(+) IgM(+) vaginal B lymphocytes from Candida-infected rats proliferated in response to stimulation with an immunodominant mannoprotein (MP) antigen of the fungus. Importantly, anti-MP antibodies and antibody-secreting B cells were detected in the supernatant and cell cultures, respectively, of vaginal B lymphocytes from infected rats incubated in vitro with vaginal T cells and stimulated with MP. No such specific antibodies were found when using vaginal B cells from uninfected rats. Furthermore, inflammatory and anti-inflammatory cytokines, such as interleukin-2 (IL-2), IL-6 and IL-10, were found in the supernatant of vaginal B cells from infected rats. These data are evidence of a partial anti-Candida protective role of CD3(-) CD5(+) IgM(+) vaginal B lymphocytes in our experimental model.

  18. Three-dimensional dosimetric considerations from different point A definitions in cervical cancer low-dose-rate brachytherapy

    PubMed Central

    Chen, Ting; Kim, Leonard H.; Nelson, Carl; Gabel, Molly; Narra, Venkat; Haffty, Bruce; Yue, Ning J.

    2013-01-01

    Purpose To investigate the dosimetric difference due to the different point A definitions in cervical cancer low-dose-rate (LDR) intracavitary brachytherapy. Material and methods Twenty CT-based LDR brachytherapy plans of 11 cervical patients were retrospectively reviewed. Two plans with point As following the modified Manchester system which defines point A being 2 cm superior to the cervical os along the tandem and 2 cm lateral (Aos), and the American Brachytherapy Society (ABS) guideline definition in which the point A is 2 cm superior to the vaginal fornices instead of os (Aovoid) were generated. Using the same source strength, two plans prescribed the same dose to Aos and Aovoid. Dosimetric differences between plans including point A dose rate, treatment volume encompassed by the prescription isodose line (TV), and dose rate of 2 cc of the rectum and bladder to the prescription dose were measured. Results On average Aovoid was 8.9 mm superior to Aos along the tandem direction with a standard deviation of 5.4 mm. With the same source strength and arrangement, Aos dose rate was 19% higher than Aovoid dose rate. The average TV(Aovoid) was 118.0 cc, which was 30% more than the average TV(Aos) of 93.0 cc. D2cc/D(Aprescribe) increased from 51% to 60% for rectum, and increased from 89% and 106% for bladder, if the prescription point changed from Aos to Aovoid. Conclusions Different point A definitions lead to significant dose differences. Careful consideration should be given when changing practice from one point A definition to another, to ensure dosimetric and clinical equivalency from the previous clinical experiences. PMID:24474971

  19. Vaginal Microbiota.

    PubMed

    Mendling, Werner

    2016-01-01

    The knowledge about the normal and abnormal vaginal microbiome has changed over the last years. Culturing techniques are not suitable any more for determination of a normal or abnormal vaginal microbiota. Non culture-based modern technologies revealed a complex and dynamic system mainly dominated by lactobacilli.The normal and the abnormal vaginal microbiota are complex ecosystems of more than 200 bacterial species influenced by genes, ethnic background and environmental and behavioral factors. Several species of lactobacilli per individuum dominate the healthy vagina. They support a defense system together with antibacterial substances, cytokines, defensins and others against dysbiosis, infections and care for an normal pregnancy without preterm birth.The numbers of Lactobacillus (L.) iners increase in the case of dysbiosis.Bacterial vaginosis (BV) - associated bacteria (BVAB), Atopobium vaginae and Clostridiales and one or two of four Gardnerella vaginalis - strains develop in different mixtures and numbers polymicrobial biofilms on the vaginal epithelium, which are not dissolved by antibiotic therapies according to guidelines and, thus, provoke recurrences.Aerobic vaginitis seems to be an immunological disorder of the vagina with influence on the microbiota, which is here dominated by aerobic bacteria (Streptococcus agalactiae, Escherichia coli). Their role in AV is unknown.Vaginal or oral application of lactobacilli is obviously able to improve therapeutic results of BV and dysbiosis.

  20. Predictors of Toxicity After Image-guided High-dose-rate Interstitial Brachytherapy for Gynecologic Cancer

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Lee, Larissa J.; Viswanathan, Akila N., E-mail: aviswanathan@lroc.harvard.edu

    2012-12-01

    Purpose: To identify predictors of grade 3-4 complications and grade 2-4 rectal toxicity after three-dimensional image-guided high-dose-rate (HDR) interstitial brachytherapy for gynecologic cancer. Methods and Materials: Records were reviewed for 51 women (22 with primary disease and 29 with recurrence) treated with HDR interstitial brachytherapy. A single interstitial insertion was performed with image guidance by computed tomography (n = 43) or magnetic resonance imaging (n = 8). The median delivered dose in equivalent 2-Gy fractions was 72.0 Gy (45 Gy for external-beam radiation therapy and 24 Gy for brachytherapy). Toxicity was reported according to the Common Toxicity Criteria for Adversemore » Events. Actuarial toxicity estimates were calculated by the Kaplan-Meier method. Results: At diagnosis, the median patient age was 62 years and the median tumor size was 3.8 cm. The median D90 and V100 were 71.4 Gy and 89.5%; the median D2cc for the bladder, rectum, and sigmoid were 64.6 Gy, 61.0 Gy, and 52.7 Gy, respectively. The actuarial rates of all grade 3-4 complications at 2 years were 20% gastrointestinal, 9% vaginal, 6% skin, 3% musculoskeletal, and 2% lymphatic. There were no grade 3-4 genitourinary complications and no grade 5 toxicities. Grade 2-4 rectal toxicity was observed in 10 patients, and grade 3-4 complications in 4; all cases were proctitis with the exception of 1 rectal fistula. D2cc for rectum was higher for patients with grade 2-4 (68 Gy vs 57 Gy for grade 0-1, P=.03) and grade 3-4 (73 Gy vs 58 Gy for grade 0-2, P=.02) rectal toxicity. The estimated dose that resulted in a 10% risk of grade 2-4 rectal toxicity was 61.8 Gy (95% confidence interval, 51.5-72.2 Gy). Discussion: Image-guided HDR interstitial brachytherapy results in acceptable toxicity for women with primary or recurrent gynecologic cancer. D2cc for the rectum is a reliable predictor of late rectal complications. Three-dimensional-based treatment planning should be performed to

  1. Vaginal Cancer—Patient Version

    Cancer.gov

    Two-thirds of vaginal cancer cases are caused by human papillomavirus (HPV). Vaccines that protect against infection with HPV may reduce the risk of vaginal cancer. When found early, vaginal cancer can often be cured. Start here to find information on vaginal cancer treatment and research.

  2. More frequent vaginal orgasm is associated with experiencing greater excitement from deep vaginal stimulation.

    PubMed

    Brody, Stuart; Klapilova, Katerina; Krejčová, Lucie

    2013-07-01

    Research indicated that: (i) vaginal orgasm (induced by penile-vaginal intercourse [PVI] without concurrent clitoral masturbation) consistency (vaginal orgasm consistency [VOC]; percentage of PVI occasions resulting in vaginal orgasm) is associated with mental attention to vaginal sensations during PVI, preference for a longer penis, and indices of psychological and physiological functioning, and (ii) clitoral, distal vaginal, and deep vaginal/cervical stimulation project via different peripheral nerves to different brain regions. The aim of this study is to examine the association of VOC with: (i) sexual arousability perceived from deep vaginal stimulation (compared with middle and shallow vaginal stimulation and clitoral stimulation), and (ii) whether vaginal stimulation was present during the woman's first masturbation. A sample of 75 Czech women (aged 18-36), provided details of recent VOC, site of genital stimulation during first masturbation, and their recent sexual arousability from the four genital sites. The association of VOC with: (i) sexual arousability perceived from the four genital sites and (ii) involvement of vaginal stimulation in first-ever masturbation. VOC was associated with greater sexual arousability from deep vaginal stimulation but not with sexual arousability from other genital sites. VOC was also associated with women's first masturbation incorporating (or being exclusively) vaginal stimulation. The findings suggest (i) stimulating the vagina during early life masturbation might indicate individual readiness for developing greater vaginal responsiveness, leading to adult greater VOC, and (ii) current sensitivity of deep vaginal and cervical regions is associated with VOC, which might be due to some combination of different neurophysiological projections of the deep regions and their greater responsiveness to penile stimulation. © 2013 International Society for Sexual Medicine.

  3. Management of aerobic vaginitis.

    PubMed

    Tempera, Gianna; Furneri, Pio Maria

    2010-01-01

    Aerobic vaginitis is a new nonclassifiable pathology that is neither specific vaginitis nor bacterial vaginosis. The diversity of this microbiological peculiarity could also explain several therapeutic failures when patients were treated for infections identified as bacterial vaginosis. The diagnosis 'aerobic vaginitis' is essentially based on microscopic examinations using a phase-contrast microscope (at ×400 magnification). The therapeutic choice for 'aerobic vaginitis' should take into consideration an antibiotic characterized by an intrinsic activity against the majority of bacteria of fecal origin, bactericidal effect and poor/absent interference with the vaginal microbiota. Regarding the therapy for aerobic vaginitis when antimicrobial agents are prescribed, not only the antimicrobial spectrum but also the presumed ecological disturbance on the anaerobic and aerobic vaginal and rectal microbiota should be taken into a consideration. Because of their very low impact on the vaginal microbiota, kanamycin or quinolones are to be considered a good choice for therapy. Copyright © 2010 S. Karger AG, Basel.

  4. SU-E-T-297: Dosimetric Assessment of An Air-Filled Balloon Applicator in HDR Vaginal Cuff Brachytherapy Using the Monte Carlo Method

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Jiang, H; Lee, Y; Pokhrel, D

    2015-06-15

    Purpose: As an alternative to cylindrical applicators, air inflated balloon applicators have been introduced into HDR vaginal cuff brachytherapy treatment to achieve sufficient dose to vagina mucosa as well as to spare rectum and bladder. In general, TG43 formulae based treatment planning systems do not take into account tissue inhomogeneity, and air in the balloon applicator can cause higher delivered dose to mucosa than treatment plan reported. We investigated dosimetric effect of air in balloon applicator using the Monte Carlo method. Methods: The thirteen-catheter Capri applicator with a Nucletron Ir-192 seed was modeled for various balloon diameters (2cm to 3.5cm)more » using the MCNP Monte Carlo code. Ir-192 seed was placed in both central and peripheral catheters to replicate real patient situations. Existence of charged particle equilibrium (CPE) with air balloon was evaluated by comparing kerma and dose at various distances (1mm to 70mm) from surface of air-filled applicator. Also mucosa dose by an air-filled applicator was compared with by a water-filled applicator to evaluate dosimetry accuracy of planning system without tissue inhomogeneity correction. Results: Beyond 1mm from air/tissue interface, the difference between kerma and dose was within 2%. CPE (or transient CPE) condition was deemed existent, and in this region no electron transport was necessary in Monte Carlo simulations. At 1mm or less, the deviation of dose from kerma became more apparent. Increase of dose to mucosa depended on diameter of air balloon. The increment of dose to mucosa was 2.5% and 4.3% on average for 2cm and 3.5cm applicators, respectively. Conclusion: After introduction of air balloon applicator, CPE fails only at the proximity of air/tissue interface. Although dose to mucosa is increased, there is no significant dosimetric difference (<5%) between air and water filled applicators. Tissue inhomogeneity correction is not necessary for air-filled applicators.« less

  5. Brachytherapy for Prostate Cancer: A Systematic Review

    PubMed Central

    Koukourakis, Georgios; Kelekis, Nikolaos; Armonis, Vassilios; Kouloulias, Vassilios

    2009-01-01

    Low-dose rate brachytherapy has become a mainstream treatment option for men diagnosed with prostate cancer because of excellent long-term treatment outcomes in low-, intermediate-, and high-risk patients. To a great extend due to patient lead advocacy for minimally invasive treatment options, high-quality prostate implants have become widely available in the US, Europe, and Japan. High-dose-rate (HDR) afterloading brachytherapy in the management of localised prostate cancer has practical, physical, and biological advantages over low-dose-rate seed brachytherapy. There are no free live sources used, no risk of source loss, and since the implant is a temporary procedure following discharge no issues with regard to radioprotection use of existing facilities exist. Patients with localized prostate cancer may benefit from high-dose-rate brachytherapy, which may be used alone in certain circumstances or in combination with external-beam radiotherapy in other settings. The purpose of this paper is to present the essentials of brachytherapies techniques along with the most important studies that support their effectiveness in the treatment of prostate cancer. PMID:19730753

  6. Vaginal Bleeding

    MedlinePlus

    ... bleeding is any vaginal bleeding unrelated to normal menstruation. This type of bleeding may include spotting of ... two or more hours. Normal vaginal bleeding, or menstruation, occurs every 21 to 35 days when the ...

  7. Vaginal Odor

    MedlinePlus

    ... usually don't cause vaginal odors. Neither do yeast infections. Generally, if you have vaginal odor without ... Avoid douching. All healthy vaginas contain bacteria and yeast. The normal acidity of your vagina keeps bacteria ...

  8. Clindamycin Vaginal

    MedlinePlus

    ... an infection caused by an overgrowth of harmful bacteria in the vagina). Clindamycin is in a class ... works by slowing or stopping the growth of bacteria. Vaginal clindamycin cannot be used to treat vaginal ...

  9. Vaginal Diseases

    MedlinePlus

    Vaginal problems are some of the most common reasons women go to the doctor. They may have ... common problem is vaginitis, an inflammation of the vagina. Other problems that affect the vagina include sexually ...

  10. Successful vaginal delivery at term after vaginal reconstruction with labium minus flaps in a patient with vaginal atresia: A rare case report.

    PubMed

    Liu, Yu; Wang, Yi-Feng

    2017-07-01

    We report a case of successful vaginal delivery after vaginal reconstruction with labium minus flaps in a 23-year-old patient with congenital vaginal atresia. The patient primarily presented with amenorrhea and cyclic abdominal pain; transabdominal ultrasonography revealed an enlarged uterus due to hematometra and absence of the lower segment of the vagina. Eight years ago, she had undergone an unsuccessful attempt at canalization at a local hospital. Upon referral to our hospital, she underwent vaginal reconstruction with labium minus flaps. Four months after this procedure, she became pregnant and, subsequently, successfully and safely vaginally delivered a healthy female baby weighing 3250 g at 38 +1 weeks' gestation. The delivery did not involve perineal laceration by lateral episiotomy. To the best of our knowledge, this is the first reported case of successful vaginal delivery at term after vaginal reconstruction with labium minus flaps in a patient with vaginal atresia. © 2017 Japan Society of Obstetrics and Gynecology.

  11. Definition of a type of abnormal vaginal flora that is distinct from bacterial vaginosis: aerobic vaginitis.

    PubMed

    Donders, Gilbert G G; Vereecken, Annie; Bosmans, Eugene; Dekeersmaecker, Alfons; Salembier, Geert; Spitz, Bernard

    2002-01-01

    To define an entity of abnormal vaginal flora: aerobic vaginitis. Observational study. University Hospital Gasthuisberg, Leuven, Belgium. 631 women attending for routine prenatal care or attending vaginitis clinic. Samples were taken for fresh wet mount microscopy of vaginal fluid, vaginal cultures and measurement of lactate, succinate and cytokine levels in vaginal fluid. Smears deficient in lactobacilli and positive for clue cells were considered to indicate a diagnosis of bacterial vaginosis. Aerobic vaginitis was diagnosed if smears were deficient in lactobacilli, positive for cocci or coarse bacilli, positive for parabasal epithelial cells, and/or positive for vaginal leucocytes (plus their granular aspect). Genital complaints include red inflammation, yellow discharge, vaginal dyspareunia. Group B streptococci, escherichia coli, staphylococcus aureus and trichomonas vaginalis are frequently cultured. Vaginal lactate concentration is severely depressed in women with aerobic vaginitis, as in bacterial vaginosis, but vaginal succinate is not produced. Also in contrast to bacterial vaginosis, aerobic vaginitis produces a host immune response that leads to high production of interleukin-6, interleukin-1-beta and leukaemia inhibitory factor in the vaginal fluid. Aerobic vaginitis is associated with aerobic micro-organisms, mainly group B streptococci and E. coli. Its characteristics are different from those of bacterial vaginosis and elicit an important host response. The most severe form of aerobic vaginitis equals desquamative inflammatory vaginitis. In theory, aerobic vaginitis may be a better candidate than bacterial vaginosis as the cause of pregnancy complications, such as ascending chorioamnionitis, preterm rupture of the membranes and preterm delivery.

  12. Patterns of care for brachytherapy in Europe. Results in Spain.

    PubMed

    López Torrecilla, J; Guedea, F; Heeren, G; Nissin, R; Ellison, T; Cottier, B

    2006-05-01

    In 2003 ESTRO began a project whose primary objective, was to make a map in the European area of infrastructures in technology and personnel for brachytherapy. A survey and a web site were elaborated. The survey was sent to the 76 Spanish Radiation Oncology departments in May 2003. By the end of 2003, 66 (86.8%) services had responded, 40 (71.4%) of which had brachytherapy. The services with brachytherapy treated 73.5% of the total patients, an average of 1,199 patients. The mean number of patients treated with brachytherapy by department was 135.5 and the number of applications was 265 annually. The average number of specialists was 7, 4 of them trained in brachytherapy. The average weekly work load of the radiation oncologists, physicists, and technicians was 22.6 h, 13.8 h and 21.0 h, respectively. The mean time dedicated to each patient by radiation oncologists, physicists and technicians was 9.2 h; 6.19 h; 7.2 h, respectively. The total number of afterloaders was 43 (22 HDR, 18 LDR, 3 PDR). The tumours most frequently treated with brachytherapy were gynaecological (56.24%), breast (14.2%) and prostate (11.7%). High dose rate was used in 47.46% of the patients and low dose rate in 47.24%. Between 1997 and 2002 there was an increase of 50.53% in patients treated with brachytherapy. The survey shows the brachytherapy resources and activity in Spain up to 2003. Increased use of brachytherapy in prostate tumours, prevalence of gynaecology brachytherapy and similar number of treatments with HDR and LDR are demonstrated in the Patterns of Care of Brachytherapy in Europe (PCBE) study in Spain.

  13. Amine content of vaginal fluid from untreated and treated patients with nonspecific vaginitis.

    PubMed Central

    Chen, K C; Forsyth, P S; Buchanan, T M; Holmes, K K

    1979-01-01

    We examined the vaginal washings from patients with nonspecific vaginitis (NSV) to seek biochemical markers and possible explanations for the signs and symptoms of this syndrome. Seven amines were identified including methylamine, isobutylamine, putrescine, cadaverine, histamine, tyramine, and phenethylamine. These amines may contribute to the symptoms of NSV and may contribute to the elevated pH of the vaginal discharge. They may also be partly responsible for the "fishy" odor that is characteristic of vaginal discharges from these patients. Among the seven amines, putrescine and cadaverine were the most abundant and were present in all vaginal discharges from each of ten patients before treatment. These amines are produced in vitro during growth of mixed vaginal bacteria in chemically defined medium, presumably by decarboxylation of the corresponding amino acids. We hypothesize the anaerobic vaginal organisms, previously shown to be quantitatively increased in NSV, are responsible for the amine production, because metronidazole inhibited the production of amines by vaginal bacteria in vitro, and Haemophilus vaginalis did not produce amines. H. vaginalis did release high concentrations of pyruvic acid and of amino acids during growth in peptone-starch-dextrose medium, whereas, other vaginal flora consumed both pyruvic acid and amino acids in the same medium during growth. These findings suggest that a symbiotic relationship may exist between H. vaginalis and other vaginal flora in patients with NSV. Images PMID:447831

  14. The American brachytherapy society survey of brachytherapy practice for carcinoma of the cervix in the United States.

    PubMed

    Nag, S; Orton, C; Young, D; Erickson, B

    1999-04-01

    The purpose of this study was to survey the brachytherapy practice for cervical cancer in the United States. The Clinical Research Committee of the American Brachytherapy Society (ABS) performed a retrospective survey of individual physicians of the ABS and American Society of Therapeutic Radiologists and Oncologists regarding the details of the brachytherapy techniques they personally used in the treatment of cervical cancer patients for the year 1995. The replies (some of which may have been an estimate only) were tabulated. The scope of this survey did not allow us to verify the data by chart audits. A total of about 3500 questionnaires were mailed out; 521 responses were received. Of these responders, 206 (40%) did not perform any brachytherapy for carcinoma of the cervix in 1995. Of the other 315 responders reporting a total of 4892 patients treated in 1995, 88% used low dose rate (LDR) while 24% used high dose rate (HDR). There was a wide variation in the doses used. For LDR treatments, the median total external beam radiation therapy (EBRT) dose was 45 and 50 Gy and the LDR dose was 42 and 45 Gy for early and advanced cancers, respectively. For HDR treatments, the median EBRT dose was 48 and 50 Gy and the median HDR dose was 29 and 30 Gy for early and advanced cancers, respectively. The median dose per fraction was 6 Gy for a median of five fractions. Interstitial brachytherapy was used as a component of the treatment in 6% of the patients by 21% of responders. Very few responders treated with pulsed or medium dose rates. This retrospective survey showed the current brachytherapy practice pattern in the treatment of cervical cancer in the United States and can serve as a basis for future prospective national brachytherapy data registry. There was wide variation in the practice pattern, emphasizing the urgent need for consensus on these issues. Copyright 1999 Academic Press.

  15. Vaginal orgasm is associated with vaginal (not clitoral) sex education, focusing mental attention on vaginal sensations, intercourse duration, and a preference for a longer penis.

    PubMed

    Brody, Stuart; Weiss, Petr

    2010-08-01

    Evidence was recently provided for vaginal orgasm, orgasm triggered purely by penile-vaginal intercourse (PVI), being associated with better psychological functioning. Common sex education and sexual medicine approaches might undermine vaginal orgasm benefits. To examine the extent to which women's vaginal orgasm consistency is associated with (i) being told in childhood or adolescence that the vagina was the important zone for inducing female orgasm; (ii) how well they focus mentally on vaginal sensations during PVI; (iii) greater PVI duration; and (iv) preference for above-average penis length.   In a representative sample of the Czech population, 1,000 women reported their vaginal orgasm consistency (from never to almost every time; only 21.9% never had a vaginal orgasm), estimates of their typical foreplay and PVI durations, what they were told in childhood and adolescence was the important zone for inducing female orgasm, their degree of focus on vaginal sensations during PVI, and whether they were more likely to orgasm with a longer than average penis. The association of vaginal orgasm consistency with the predictors noted above. Vaginal orgasm consistency was associated with all hypothesized correlates. Multivariate analysis indicated the most important predictors were being educated that the vagina is important for female orgasm, being mentally focused on vaginal sensations during PVI, and in some analyses duration of PVI (but not foreplay) and preferring a longer than average penis. Focusing attention on penile-vaginal sensation supports vaginal orgasm and the myriad benefits thereof. Brody S, and Weiss P. Vaginal orgasm is associated with vaginal (not clitoral) sex education, focusing mental attention on vaginal sensations, intercourse duration, and a preference for a longer penis. © 2009 International Society for Sexual Medicine.

  16. Vaginal cysts

    MedlinePlus

    ... essential to determine what type of cyst or mass you may have. A mass or bulge of the vaginal wall may be ... to rule out vaginal cancer, especially if the mass appears to be solid. If the cyst is ...

  17. Menopause and the vaginal microbiome.

    PubMed

    Muhleisen, Alicia L; Herbst-Kralovetz, Melissa M

    2016-09-01

    For over a century it has been well documented that bacteria in the vagina maintain vaginal homeostasis, and that an imbalance or dysbiosis may be associated with poor reproductive and gynecologic health outcomes. Vaginal microbiota are of particular significance to postmenopausal women and may have a profound effect on vulvovaginal atrophy, vaginal dryness, sexual health and overall quality of life. As molecular-based techniques have evolved, our understanding of the diversity and complexity of this bacterial community has expanded. The objective of this review is to compare the changes that have been identified in the vaginal microbiota of menopausal women, outline alterations in the microbiome associated with specific menopausal symptoms, and define how hormone replacement therapy impacts the vaginal microbiome and menopausal symptoms; it concludes by considering the potential of probiotics to reinstate vaginal homeostasis following menopause. This review details the studies that support the role of Lactobacillus species in maintaining vaginal homeostasis and how the vaginal microbiome structure in postmenopausal women changes with decreasing levels of circulating estrogen. In addition, the associated transformations in the microanatomical features of the vaginal epithelium that can lead to vaginal symptoms associated with menopause are described. Furthermore, hormone replacement therapy directly influences the dominance of Lactobacillus in the microbiota and can resolve vaginal symptoms. Oral and vaginal probiotics hold great promise and initial studies complement the findings of previous research efforts concerning menopause and the vaginal microbiome; however, additional trials are required to determine the efficacy of bacterial therapeutics to modulate or restore vaginal homeostasis. Copyright © 2016 Elsevier Ireland Ltd. All rights reserved.

  18. 10 CFR 35.2406 - Records of brachytherapy source accountability.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... 10 Energy 1 2010-01-01 2010-01-01 false Records of brachytherapy source accountability. 35.2406... Records of brachytherapy source accountability. (a) A licensee shall maintain a record of brachytherapy source accountability required by § 35.406 for 3 years. (b) For temporary implants, the record must...

  19. Prevalence of vaginal candidiasis among pregnant women with abnormal vaginal discharge in Maiduguri.

    PubMed

    Ibrahim, S M; Bukar, M; Mohammed, Y; Mohammed, B; Yahaya, M; Audu, B M; Ibrahim, H M; Ibrahim, H A

    2013-01-01

    Pregnancy represents a risk factor in the occurrence of vaginal candidiasis. To determine the prevalence and clinical features associated with abnormal vaginal discharge and C. albicans infection in pregnant women. High vaginal swab samples and data on epidemiological characteristics were collected from 400 pregnant women with complaints of abnormal vaginal discharge at booking clinic of University of Maiduguri Teaching Hospital. The data was analysed using SPSS 16.0 statistical software. The prevalence of abnormal vaginal discharge in pregnancy was 31.5%. The frequency of abnormal vaginal discharge was 183 (45.8%) among those aged 20-24 years, 291 (72.8%) in multipara, 223 (55.8%) in those with Primary education and 293 (73.2%) in unemployed. Vulval pruritus 300 (75.0%) was significantly related to abnormal vaginal discharge (P < 0.001). The prevalence of C. albicans was 41%. The frequencies of Vulval itching, Dyspareunia and vulval excoriation among those with candidiasis were 151 (50.3%), 14 (56.0%) and 75 (75.0%) respectively (P < 0.001). The prevalence of abnormal vaginal discharge in pregnancy was high in this study and C. albicans was the commonest cause. It is recommended that a pregnant woman complaining of abnormal vaginal discharge be assessed and Laboratory diagnosis done in order to give appropriate treatment.

  20. Engine Cylinder Temperature Control

    DOEpatents

    Kilkenny, Jonathan Patrick; Duffy, Kevin Patrick

    2005-09-27

    A method and apparatus for controlling a temperature in a combustion cylinder in an internal combustion engine. The cylinder is fluidly connected to an intake manifold and an exhaust manifold. The method and apparatus includes increasing a back pressure associated with the exhaust manifold to a level sufficient to maintain a desired quantity of residual exhaust gas in the cylinder, and varying operation of an intake valve located between the intake manifold and the cylinder to an open duration sufficient to maintain a desired quantity of fresh air from the intake manifold to the cylinder, wherein controlling the quantities of residual exhaust gas and fresh air are performed to maintain the temperature in the cylinder at a desired level.

  1. Delamination of Composite Cylinders

    NASA Astrophysics Data System (ADS)

    Davies, Peter; Carlsson, Leif A.

    The delamination resistance of filament wound glass/epoxy cylinders has been characterized for a range of winding angles and fracture mode ratios using beam fracture specimens. The results reveal that the delamination fracture resistance increases with increasing winding angle and mode II (shear) fraction (GΠ/G). It was also found that interlaced fiber bundles in the filament wound cylinder wall acted as effective crack arresters in mode I loading. To examine the sensitivity of delamina-tion damage on the strength of the cylinders, external pressure tests were performed on filament-wound glass/epoxy composite cylinders with artificial defects and impact damage. The results revealed that the cylinder strength was insensitive to the presence of single delaminations but impact damage caused reductions in failure pressure. The insensitivity of the failure pressure to a single delamination is attributed to the absence of buckling of the delaminated sublaminates before the cylinder wall collapsed. The impacted cylinders contained multiple delaminations, which caused local reduction in the compressive load capability and reduction in failure pressure. The response of glass/epoxy cylinders was compared to impacted carbon reinforced cylinders. Carbon/epoxy is more sensitive to damage but retains higher implosion resistance while carbon/PEEK shows the opposite trend.

  2. Mental Nerve Blocks for Lip Brachytherapy: A Case Report.

    PubMed

    Hafez, Osama; Ackerman, Robert S; Evans, Trip; Patel, Sephalie Y; Padalia, Devang M

    2018-05-15

    High dose rate interstitial brachytherapy is a commonly performed procedure for carcinoma of the lower lip. Placement of the brachytherapy catheters can be painful and may require monitored anesthesia care or general anesthesia. We present the use of bilateral mental nerve blocks with minimal sedation to facilitate placement of brachytherapy catheters.

  3. The use of tetrahedral mesh geometries in Monte Carlo simulation of applicator based brachytherapy dose distributions

    NASA Astrophysics Data System (ADS)

    Paiva Fonseca, Gabriel; Landry, Guillaume; White, Shane; D'Amours, Michel; Yoriyaz, Hélio; Beaulieu, Luc; Reniers, Brigitte; Verhaegen, Frank

    2014-10-01

    Accounting for brachytherapy applicator attenuation is part of the recommendations from the recent report of AAPM Task Group 186. To do so, model based dose calculation algorithms require accurate modelling of the applicator geometry. This can be non-trivial in the case of irregularly shaped applicators such as the Fletcher Williamson gynaecological applicator or balloon applicators with possibly irregular shapes employed in accelerated partial breast irradiation (APBI) performed using electronic brachytherapy sources (EBS). While many of these applicators can be modelled using constructive solid geometry (CSG), the latter may be difficult and time-consuming. Alternatively, these complex geometries can be modelled using tessellated geometries such as tetrahedral meshes (mesh geometries (MG)). Recent versions of Monte Carlo (MC) codes Geant4 and MCNP6 allow for the use of MG. The goal of this work was to model a series of applicators relevant to brachytherapy using MG. Applicators designed for 192Ir sources and 50 kV EBS were studied; a shielded vaginal applicator, a shielded Fletcher Williamson applicator and an APBI balloon applicator. All applicators were modelled in Geant4 and MCNP6 using MG and CSG for dose calculations. CSG derived dose distributions were considered as reference and used to validate MG models by comparing dose distribution ratios. In general agreement within 1% for the dose calculations was observed for all applicators between MG and CSG and between codes when considering volumes inside the 25% isodose surface. When compared to CSG, MG required longer computation times by a factor of at least 2 for MC simulations using the same code. MCNP6 calculation times were more than ten times shorter than Geant4 in some cases. In conclusion we presented methods allowing for high fidelity modelling with results equivalent to CSG. To the best of our knowledge MG offers the most accurate representation of an irregular APBI balloon applicator.

  4. Vaginal Fistula

    MedlinePlus

    Vaginal fistula Overview A vaginal fistula is an abnormal opening that connects your vagina to another organ, such as your bladder, colon or rectum. Your ... describe the condition as a hole in your vagina that allows stool or urine to pass through ...

  5. Internal combustion engine cylinder-to-cylinder balancing with balanced air-fuel ratios

    DOEpatents

    Harris, Ralph E.; Bourn, Gary D.; Smalley, Anthony J.

    2006-01-03

    A method of balancing combustion among cylinders of an internal combustion engine. For each cylinder, a normalized peak firing pressure is calculated as the ratio of its peak firing pressure to its combustion pressure. Each cylinder's normalized peak firing pressure is compared to a target value for normalized peak firing pressure. The fuel flow is adjusted to any cylinder whose normalized peak firing pressure is not substantially equal to the target value.

  6. Comparison between vaginal royal jelly and vaginal estrogen effects on quality of life and vaginal atrophy in postmenopausal women: a clinical trial study.

    PubMed

    Seyyedi, Fatemeh; Kopaei, Mahmoud Rafiean; Miraj, Sepideh

    2016-11-01

    This study was conducted to evaluate the therapeutic effects of vaginal royal jelly and vaginal estrogen on quality of life and vaginal atrophy in postmenopausal women. This double-blind randomized controlled clinical trial was carried out at gynecology and obstetrics clinics of Hajar Hospital of Shahrekord University of Medical Sciences (Iran) from January 2013 to January 2014. The study was conducted on married postmenopausal women between 50 and 65 years old. Of 120 patients, 30 individuals were excluded based on the exclusion criteria, and 90 women were randomly distributed into three groups of 30 royal jelly vaginal cream 15%, vaginal Premarin, and placebo (lubricant), for three months. At the beginning and the end of the study, quality of life and vaginal cytology assay were evaluated. Data were analyzed by SPSS Version 11. Vaginal cream of royal jelly is significantly more effective than vaginal cream of Premarin and lubricant in improvement of quality of life in postmenopausal women (p<0.05). Moreover, Pap smear results showed that vaginal atrophy in vaginal Premarin group was lower than the other groups (p<0.001), and there was no significant difference between lubricant and royal jelly groups (p=0.89). Administration of vaginal royal jelly was effective in quality-of-life improvement of postmenopausal women. Given to the various properties of royal jelly and its effectiveness on quality of life and vaginal atrophy in postmenopausal women, further studies are recommended for using =royal jelly in improving menopausal symptoms. The trial was registered at the Iranian Registry of Clinical Trials (http://www.irct.ir) with the IRCT code: 2014112220043n1. Shahrekord University of Medical Sciences supported this research (project no. 1440).

  7. Brachytherapy for cervix cancer: low-dose rate or high-dose rate brachytherapy – a meta-analysis of clinical trials

    PubMed Central

    Viani, Gustavo A; Manta, Gustavo B; Stefano, Eduardo J; de Fendi, Ligia I

    2009-01-01

    Background The literature supporting high-dose rate brachytherapy (HDR) in the treatment of cervical carcinoma derives primarily from retrospective series. However, controversy still persists regarding the efficacy and safety of HDR brachytherapy compared to low-dose rate (LDR) brachytherapy, in particular, due to inadequate tumor coverage for stage III patients. Whether LDR or HDR brachytherapy produces better results for these patients in terms of survival rate, local control rate and the treatment complications remain controversial. Methods A meta-analysis of RCT was performed comparing LDR to HDR brachytherapy for cervix cancer treated for radiotherapy alone. The MEDLINE, EMBASE, CANCERLIT and Cochrane Library databases, as well as abstracts published in the annual proceedings were systematically searched. We assessed methodological quality for each outcome by grading the quality of evidence using the Grading of Recommendations Assessment, Development and Evaluation (GRADE) methodology. We used "recommend" for strong recommendations, and "suggest" for weak recommendations. Results Pooled results from five randomized trials (2,065 patients) of HDR brachytherapy in cervix cancer showed no significant increase of mortality (p = 0.52), local recurrence (p = 0.68), or late complications (rectal; p = 0.7, bladder; p = 0.95 or small intestine; p = 0.06) rates as compared to LDR brachytherapy. In the subgroup analysis no difference was observed for overall mortality and local recurrence in patients with clinical stages I, II and III. The quality of evidence was low for mortality and local recurrence in patients with clinical stage I, and moderate for other clinical stages. Conclusion Our meta-analysis shows that there are no differences between HDR and LDR for overall survival, local recurrence and late complications for clinical stages I, II and III. By means of the GRADE system, we recommend the use of HDR for all clinical stages of cervix cancer. PMID:19344527

  8. Vaginal lactobacilli profile in pregnant women with normal & abnormal vaginal flora.

    PubMed

    Yeruva, Thirupathaiah; Rajkumar, Hemalatha; Donugama, Vasundhara

    2017-10-01

    Lactobacilli species that are better adapted to vaginal environment of women may colonize better and offer protection against vaginal pathogenic bacteria. In this study, the distribution of common Lactobacillus species was investigated in pregnant women. Sixty seven pregnant women were included in the study and vaginal samples were collected for Gram staining. Women were classified as normal vaginal flora, intermediate flora and bacterial vaginosis (BV) based on Nugent's score. Vaginal samples were also collected for the identification of Lactobacillus spp. by multiplex polymerase chain reaction (PCR) profiling of 16S rDNA amplification method. Lactobacillus crispatus (100%) was the most predominant Lactobacillus spp. present in pregnant women with normal flora, followed by L. iners (77%), L. jensenii (74%) and L. helveticus (60%). While, L. iners was commonly present across groups in women with normal, intermediate or BV flora, L. crispatus, L. jensenii and L. helveticus decreased significantly as the vaginal flora changed to intermediate and BV. In women with BV, except L. iners other species of lactobacilli was less frequently prevalent. Species such as L. rhamnosus, L. fermentum, L. paracasei and L. casei were not detected in any vaginal sample. L. crispatus, L. jensinii and L. helveticus were predominant species in women with normal flora. L. crispatus alone or in combination with L. jensinii and L. helveticus may be evaluated for probiotic properties for the prevention and treatment of BV.

  9. Current status of brachytherapy in Korea: a national survey of radiation oncologists

    PubMed Central

    Kim, Joo-Young; Park, Won; Kim, Young Seok

    2016-01-01

    Objective The aim of the present study was to acquire information on brachytherapy resources in Korea through a national survey of radiation oncologists. Methods Between October 2014 and January 2015, a questionnaire on the current status of brachytherapy was distributed to all 86 radiation oncology departments in Korea. The questionnaire was divided into sections querying general information on human resources, brachytherapy equipment, and suggestions for future directions of brachytherapy policy in Korea. Results The response rate of the survey was 88.3%. The average number of radiation oncologists per center was 2.3. At the time of survey, 28 centers (36.8%) provided brachytherapy to patients. Among the 28 brachytherapy centers, 15 (53.5%) were located in in the capital Seoul and its surrounding metropolitan areas. All brachytherapy centers had a high-dose rate system using 192Ir (26 centers) or 60Co (two centers). Among the 26 centers using 192Ir sources, 11 treated fewer than 40 patients per year. In the two centers using 60Co sources, the number of patients per year was 16 and 120, respectively. The most frequently cited difficulties in performing brachytherapy were cost related. A total of 21 centers had a plan to sustain the current brachytherapy system, and four centers noted plans to upgrade their brachytherapy system. Two centers stated that they were considering discontinuation of brachytherapy due to cost burdens of radioisotope source replacement. Conclusion The present study illustrated the current status of brachytherapy in Korea. Financial difficulties were the major barriers to the practice of brachytherapy. PMID:27102244

  10. Current status of brachytherapy in Korea: a national survey of radiation oncologists.

    PubMed

    Kim, Haeyoung; Kim, Joo Young; Kim, Juree; Park, Won; Kim, Young Seok; Kim, Hak Jae; Kim, Yong Bae

    2016-07-01

    The aim of the present study was to acquire information on brachytherapy resources in Korea through a national survey of radiation oncologists. Between October 2014 and January 2015, a questionnaire on the current status of brachytherapy was distributed to all 86 radiation oncology departments in Korea. The questionnaire was divided into sections querying general information on human resources, brachytherapy equipment, and suggestions for future directions of brachytherapy policy in Korea. The response rate of the survey was 88.3%. The average number of radiation oncologists per center was 2.3. At the time of survey, 28 centers (36.8%) provided brachytherapy to patients. Among the 28 brachytherapy centers, 15 (53.5%) were located in in the capital Seoul and its surrounding metropolitan areas. All brachytherapy centers had a high-dose rate system using (192)Ir (26 centers) or (60)Co (two centers). Among the 26 centers using (192)Ir sources, 11 treated fewer than 40 patients per year. In the two centers using (60)Co sources, the number of patients per year was 16 and 120, respectively. The most frequently cited difficulties in performing brachytherapy were cost related. A total of 21 centers had a plan to sustain the current brachytherapy system, and four centers noted plans to upgrade their brachytherapy system. Two centers stated that they were considering discontinuation of brachytherapy due to cost burdens of radioisotope source replacement. The present study illustrated the current status of brachytherapy in Korea. Financial difficulties were the major barriers to the practice of brachytherapy.

  11. Vaginal biogenic amines: biomarkers of bacterial vaginosis or precursors to vaginal dysbiosis?

    PubMed Central

    Nelson, Tiffanie M.; Borgogna, Joanna-Lynn C.; Brotman, Rebecca M.; Ravel, Jacques; Walk, Seth T.; Yeoman, Carl J.

    2015-01-01

    Bacterial vaginosis (BV) is the most common vaginal disorder among reproductive age women. One clinical indicator of BV is a “fishy” odor. This odor has been associated with increases in several biogenic amines (BAs) that may serve as important biomarkers. Within the vagina, BA production has been linked to various vaginal taxa, yet their genetic capability to synthesize BAs is unknown. Using a bioinformatics approach, we show that relatively few vaginal taxa are predicted to be capable of producing BAs. Many of these taxa (Dialister, Prevotella, Parvimonas, Megasphaera, Peptostreptococcus, and Veillonella spp.) are more abundant in the vaginal microbial community state type (CST) IV, which is depleted in lactobacilli. Several of the major Lactobacillus species (L. crispatus, L. jensenii, and L. gasseri) were identified as possessing gene sequences for proteins predicted to be capable of putrescine production. Finally, we show in a small cross sectional study of 37 women that the BAs putrescine, cadaverine and tyramine are significantly higher in CST IV over CSTs I and III. These data support the hypothesis that BA production is conducted by few vaginal taxa and may be important to the outgrowth of BV-associated (vaginal dysbiosis) vaginal bacteria. PMID:26483694

  12. Vaginal biogenic amines: biomarkers of bacterial vaginosis or precursors to vaginal dysbiosis?

    PubMed

    Nelson, Tiffanie M; Borgogna, Joanna-Lynn C; Brotman, Rebecca M; Ravel, Jacques; Walk, Seth T; Yeoman, Carl J

    2015-01-01

    Bacterial vaginosis (BV) is the most common vaginal disorder among reproductive age women. One clinical indicator of BV is a "fishy" odor. This odor has been associated with increases in several biogenic amines (BAs) that may serve as important biomarkers. Within the vagina, BA production has been linked to various vaginal taxa, yet their genetic capability to synthesize BAs is unknown. Using a bioinformatics approach, we show that relatively few vaginal taxa are predicted to be capable of producing BAs. Many of these taxa (Dialister, Prevotella, Parvimonas, Megasphaera, Peptostreptococcus, and Veillonella spp.) are more abundant in the vaginal microbial community state type (CST) IV, which is depleted in lactobacilli. Several of the major Lactobacillus species (L. crispatus, L. jensenii, and L. gasseri) were identified as possessing gene sequences for proteins predicted to be capable of putrescine production. Finally, we show in a small cross sectional study of 37 women that the BAs putrescine, cadaverine and tyramine are significantly higher in CST IV over CSTs I and III. These data support the hypothesis that BA production is conducted by few vaginal taxa and may be important to the outgrowth of BV-associated (vaginal dysbiosis) vaginal bacteria.

  13. Vaginal bleeding in pregnancy

    MedlinePlus

    Pregnancy - vaginal bleeding; Maternal blood loss - vaginal ... Up to 1 in 4 women have vaginal bleeding at some time during their pregnancy. Bleeding is more common in the first 3 months (first trimester), especially with twins.

  14. Vaginitis: diagnosis and management.

    PubMed

    Faro, S

    1996-01-01

    The various conditions that give rise to vaginitis include specific and nonspecific entities, such as candidiasis, trichomoniasis, bacterial vaginosis, group B streptococcal vaginitis, purulent vaginitis, volvodynia, and vestibulitis. The patient with chronic vaginitis usually develops this condition because of a misdiagnosis. It is critical that patients who have chronic vaginitis be thoroughly evaluated to determine if there is a specific etiology and whether their condition is recurrent or persistent, or is a reinfection. This also must include obtaining a detailed history, beginning with the patient's best recollection of when she felt perfectly normal. The physician must have an understanding of a healthy vaginal ecosystem and what mechanisms are in place to maintain the equilibrium. The vaginal ecosystem is a complex system of micro-organisms interacting with host factors to maintain its equilibrium. The endogenous microflora consists of a variety of bacteria, which include aerobic, facultative and obligate anaerobic bacteria. These organisms exist in a commensal, synergistic or antagonistic relationship. Therefore, it is important to understand what factors control the delicate equilibrium of the vaginal ecosystem, and which factors, both endogenous and exogenous, can disrupt this system. It is also important for the physician to understand that when a patient has symptoms of vaginitis it is not always due to an infectious etiology. There are situations in which an inflammatory reaction occurs but the specific etiology may not be determined. Thus, it is important that the physician not rush through the history or the examination.

  15. 4. View showing cylinder end of two, cylinder, compound Corliss ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    4. View showing cylinder end of two, cylinder, compound Corliss steam engine with tandem air compressor. - International Smelting & Refining Company, Tooele Smelter, Powerhouse, State Route 178, Tooele, Tooele County, UT

  16. Comparison between vaginal royal jelly and vaginal estrogen effects on quality of life and vaginal atrophy in postmenopausal women: a clinical trial study

    PubMed Central

    Seyyedi, Fatemeh; Kopaei, Mahmoud Rafiean; Miraj, Sepideh

    2016-01-01

    Objective This study was conducted to evaluate the therapeutic effects of vaginal royal jelly and vaginal estrogen on quality of life and vaginal atrophy in postmenopausal women. Methods This double-blind randomized controlled clinical trial was carried out at gynecology and obstetrics clinics of Hajar Hospital of Shahrekord University of Medical Sciences (Iran) from January 2013 to January 2014. The study was conducted on married postmenopausal women between 50 and 65 years old. Of 120 patients, 30 individuals were excluded based on the exclusion criteria, and 90 women were randomly distributed into three groups of 30 royal jelly vaginal cream 15%, vaginal Premarin, and placebo (lubricant), for three months. At the beginning and the end of the study, quality of life and vaginal cytology assay were evaluated. Data were analyzed by SPSS Version 11. Results Vaginal cream of royal jelly is significantly more effective than vaginal cream of Premarin and lubricant in improvement of quality of life in postmenopausal women (p<0.05). Moreover, Pap smear results showed that vaginal atrophy in vaginal Premarin group was lower than the other groups (p<0.001), and there was no significant difference between lubricant and royal jelly groups (p=0.89). Conclusion Administration of vaginal royal jelly was effective in quality-of-life improvement of postmenopausal women. Given to the various properties of royal jelly and its effectiveness on quality of life and vaginal atrophy in postmenopausal women, further studies are recommended for using =royal jelly in improving menopausal symptoms. Clinical trial registration The trial was registered at the Iranian Registry of Clinical Trials (http://www.irct.ir) with the IRCT code: 2014112220043n1. Funding Shahrekord University of Medical Sciences supported this research (project no. 1440). PMID:28070251

  17. Vaginal Cancer—Health Professional Version

    Cancer.gov

    Vaginal cancer is often squamous cell carcinoma. Other types of vaginal cancer are adenocarcinoma, melanoma, and sarcoma. Infection with certain types of human papillomavirus (HPV) causes most vaginal cancer. Find evidence-based information on vaginal cancer treatment and research.

  18. Vaginal drug distribution modeling.

    PubMed

    Katz, David F; Yuan, Andrew; Gao, Yajing

    2015-09-15

    This review presents and applies fundamental mass transport theory describing the diffusion and convection driven mass transport of drugs to the vaginal environment. It considers sources of variability in the predictions of the models. It illustrates use of model predictions of microbicide drug concentration distribution (pharmacokinetics) to gain insights about drug effectiveness in preventing HIV infection (pharmacodynamics). The modeling compares vaginal drug distributions after different gel dosage regimens, and it evaluates consequences of changes in gel viscosity due to aging. It compares vaginal mucosal concentration distributions of drugs delivered by gels vs. intravaginal rings. Finally, the modeling approach is used to compare vaginal drug distributions across species with differing vaginal dimensions. Deterministic models of drug mass transport into and throughout the vaginal environment can provide critical insights about the mechanisms and determinants of such transport. This knowledge, and the methodology that obtains it, can be applied and translated to multiple applications, involving the scientific underpinnings of vaginal drug distribution and the performance evaluation and design of products, and their dosage regimens, that achieve it. Copyright © 2015 Elsevier B.V. All rights reserved.

  19. Long duration mild temperature hyperthermia and brachytherapy.

    PubMed

    Armour, E P; Raaphorst, G P

    2004-03-01

    Combining long duration mild temperature hyperthermia (LDMH) and low dose-rate (LDR) brachytherapy to enhance therapeutic killing of cancer cells was proposed many years ago. The cellular and tumour research that supports this hypothesis is presented in this review. Research describing LDMH interaction with pulsed brachytherapy and high dose-rate brachytherapy using clinically relevant parameters are compared with LDMH/LDR brachytherapy. The mechanism by which LDMH sensitizes LDR has been established as the inhibition of sublethal damage repair. The molecular mechanisms have been shown to involve DNA repair enzymes, but the exact nature of these processes is still under investigation. The relative differences between LDMH interactions with human and rodent cells are presented to help in the understanding of possible roles of LDMH in clinical application. The role of LDMH in modifying tumour blood flow and its possible role in LDR sensitization of tumours is also presented. The positive aspects of LDMH-brachytherapy for clinical application are sixfold; (1) the thermal goals (temperature, time and volume) are achievable with currently available technology, (2) the hyperthermia by itself has no detectable toxic effects, (3) thermotolerance appears to play a minor if any role in radiation sensitization, (4) TER of around 2 can be expected, (5) hypoxic fraction may be decreased due to blood flow modification and (6) simultaneous chemotherapy may also be sensitized. Combined LDMH and brachytherapy is a cancer therapy that has established biological rationale and sufficient technical and clinical advancements to be appropriately applied. This modality is ripe for clinical testing.

  20. Vaginal Cancer

    MedlinePlus

    Vaginal cancer is a rare type of cancer. It is more common in women 60 and older. You are also more likely to get it if you have had a human ... test can find abnormal cells that may be cancer. Vaginal cancer can often be cured in its ...

  1. 21 CFR 892.5730 - Radionuclide brachytherapy source.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Radionuclide brachytherapy source. 892.5730 Section 892.5730 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES RADIOLOGY DEVICES Therapeutic Devices § 892.5730 Radionuclide brachytherapy...

  2. The effect of vaginal cream containing ginger in users of clotrimazole vaginal cream on vaginal candidiasis.

    PubMed

    Shabanian, Sheida; Khalili, Sima; Lorigooini, Zahra; Malekpour, Afsaneh; Heidari-Soureshjani, Saeid

    2017-01-01

    Vulvovaginal candidiasis is one of the most common infections of the genital tract in women that causes many complications. Therefore, we examined the clinical effect of ginger cream along with clotrimazole compared to vaginal clotrimazole alone in this study. This double-blind clinical trial was conducted on 67 women admitted to the Gynecology Clinic of Hajar Hospital with vaginal candidiasis. The patients were divided randomly into two groups of 33 and 34 people. The diagnosis was made according to clinical symptoms, wet smear, and culture. Ginger-clotrimazole vaginal cream 1% and clotrimazole vaginal cream 1% were administered to groups 1 and 2, respectively, once a day for 7 days and therapeutic effects and symptoms were evaluated in readmission. Data analysis was performed using SPSS version 22, t -test and Chi-square. The mean value of variables itching ( P > 0.05), burning ( P > 0.05), and cheesy secretion ( P < 0.05) in users of ginger-clotrimazole was less than the other group after the treatment. Recurrence in clotrimazole group was 48.5% and in ginger-clotrimazole group 51.2% during the 1-month follow-up with no significant difference. Study results showed that cream containing ginger and clotrimazole 1% was more effective and may be more useful than the clotrimazole to treat vaginal candidiasis.

  3. Vaginal mucosal flap as a sling preservation for the treatment of vaginal exposure of mesh.

    PubMed

    Kim, Sea Young; Park, Jong Yeon; Kim, Han Kwon; Park, Chang Hoo; Kim, Sung Jin; Sung, Gi Teck; Park, Chang Myon

    2010-06-01

    Tension-free vaginal tape (TVT) procedures are used for the treatment of stress urinary incontinence in women. The procedures with synthetic materials can have a risk of vaginal erosion. We experienced transobturator suburethral sling (TOT) tape-induced vaginal erosion and report the efficacy of a vaginal mucosal covering technique. A total of 560 female patients diagnosed with stress urinary incontinence underwent TOT procedures at our hospital between January 2005 and August 2009. All patients succeeded in follow-ups, among which 8 patients (mean age: 50.5 years) presented with vaginal exposure of the mesh. A vaginal mucosal covering technique was performed under local anesthesia after administration of antibiotics and vaginal wound dressings for 3-4 days. Seven of the 8 patients complained of persistent vaginal discharge postoperatively. Two of the 8 patients complained of dyspareunia of their male partners. The one remaining patient was otherwise asymptomatic, but mesh erosion was discovered at the routine follow-up visit. Six of the 8 patients showed complete mucosal covering of the mesh after the operation (mean follow-up period: 16 moths). Vaginal mucosal erosion recurred in 2 patients, and the mesh was then partially removed. One patient had recurrent stress urinary incontinence. Vaginal mucosal covering as a sling preservation with continued patient continence may be a feasible and effective option for the treatment of vaginal exposure of mesh after TOT tape procedures.

  4. [Valorisation of brachytherapy and medico-economic considerations].

    PubMed

    Pommier, P; Morelle, M; Millet-Lagarde, F; Peiffert, D; Gomez, F; Perrier, L

    2013-04-01

    Economic data in the literature for brachytherapy are still sparse and heterogeneous, with few controlled prospective studies and a perspective most often limited to those of the provider (health insurances). Moreover, these observation and conclusions are difficult to generalize in France. The prospective health economic studies performed in France in the framework of a national program to sustain innovative and costly therapies (STIC program) launched by the French cancer national institute are therefore of most importance. With the exception of prostate brachytherapy with permanent seeds, the valorisation of the brachytherapy activity by the French national health insurance does not take into account the degree of complexity and the real costs supported by health institutions (i.e. no specific valorisation for 3D image-based treatment planning and dose optimization and for the use of pulsed dose rate brachytherapy). Copyright © 2013 Société française de radiothérapie oncologique (SFRO). Published by Elsevier SAS. All rights reserved.

  5. High versus low-dose rate brachytherapy for cervical cancer.

    PubMed

    Patankar, Sonali S; Tergas, Ana I; Deutsch, Israel; Burke, William M; Hou, June Y; Ananth, Cande V; Huang, Yongmei; Neugut, Alfred I; Hershman, Dawn L; Wright, Jason D

    2015-03-01

    Brachytherapy plays an important role in the treatment of cervical cancer. While small trials have shown comparable survival outcomes between high (HDR) and low-dose rate (LDR) brachytherapy, little data is available in the US. We examined the utilization of HDR brachytherapy and analyzed the impact of type of brachytherapy on survival for cervical cancer. Women with stages IB2-IVA cervical cancer treated with primary (external beam and brachytherapy) radiotherapy between 2003-2011 and recorded in the National Cancer Database (NCDB) were analyzed. Generalized linear mixed models and Cox proportional hazards regression were used to examine predictors of HDR brachytherapy use and the association between HDR use and survival. A total of 10,564 women including 2681 (25.4%) who received LDR and 7883 (74.6%) that received HDR were identified. Use of HDR increased from 50.2% in 2003 to 83.9% in 2011 (P<0.0001). In a multivariable model, year of diagnosis was the strongest predictor of use of HDR. While patients in the Northeast were more likely to receive HDR therapy, there were no other clinical or socioeconomic characteristics associated with receipt of HDR. In a multivariable Cox model, survival was similar between the HDR and LDR groups (HR=0.93; 95% CI 0.83-1.03). Similar findings were noted in analyses stratified by stage and histology. Kaplan-Meier analyses demonstrated no difference in survival based on type of brachytherapy for stage IIB (P=0.68), IIIB (P=0.17), or IVA (P=0.16) tumors. The use of HDR therapy has increased rapidly. Overall survival is similar for LDR and HDR brachytherapy. Copyright © 2015 Elsevier Inc. All rights reserved.

  6. High versus Low-Dose Rate Brachytherapy for Cervical Cancer

    PubMed Central

    Patankar, Sonali S.; Tergas, Ana I.; Deutsch, Israel; Burke, William M.; Hou, June Y.; Ananth, Cande V.; Huang, Yongmei; Neugut, Alfred I.; Hershman, Dawn L.; Wright, Jason D.

    2015-01-01

    Objectives Brachytherapy plays an important role in the treatment of cervical cancer. While small trials have shown comparable survival outcomes between high (HDR) and low-dose rate (LDR) brachytherapy, little data is available in the US. We examined the utilization of HDR brachytherapy and analyzed the impact of type of brachytherapy on survival for cervical cancer. Methods Women with stage IB2–IVA cervical cancer treated with primary (external beam and brachytherapy) radiotherapy between 2003–2011 and recorded in the National Cancer Database (NCDB) were analyzed. Generalized linear mixed models and Cox proportional hazards regression were used to examine predictors of HDR brachytherapy use and the association between HDR use and survival. Results A total of 10,564 women including 2681 (25.4%) who received LDR and 7883 (74.6%) that received HDR were identified. Use of HDR increased from 50.2% in 2003 to 83.9% in 2011 (P<0.0001). In a multivariable model, year of diagnosis was the strongest predictor of use of HDR. While patients in the Northeast were more likely to receive HDR therapy, there were no other clinical or socioeconomic characteristics associated with receipt of HDR. In a multivariable Cox model, survival was similar between the HDR and LDR groups (HR=0.93; 95% 0.83–1.03). Similar findings were noted in analyses stratified by stage and histology. Kaplan-Meier analyses demonstrated no difference in survival based on type of brachytherapy for stage IIB (P=0.68), IIIB (P=0.17), or IVA (P=0.16) tumors. Conclusions The use of HDR therapy has increased rapidly. Overall survival is similar for LDR and HDR brachytherapy. PMID:25575481

  7. Lactobacilli Dominance and Vaginal pH: Why Is the Human Vaginal Microbiome Unique?

    PubMed

    Miller, Elizabeth A; Beasley, DeAnna E; Dunn, Robert R; Archie, Elizabeth A

    2016-01-01

    The human vaginal microbiome is dominated by bacteria from the genus Lactobacillus , which create an acidic environment thought to protect women against sexually transmitted pathogens and opportunistic infections. Strikingly, lactobacilli dominance appears to be unique to humans; while the relative abundance of lactobacilli in the human vagina is typically >70%, in other mammals lactobacilli rarely comprise more than 1% of vaginal microbiota. Several hypotheses have been proposed to explain humans' unique vaginal microbiota, including humans' distinct reproductive physiology, high risk of STDs, and high risk of microbial complications linked to pregnancy and birth. Here, we test these hypotheses using comparative data on vaginal pH and the relative abundance of lactobacilli in 26 mammalian species and 50 studies ( N = 21 mammals for pH and 14 mammals for lactobacilli relative abundance). We found that non-human mammals, like humans, exhibit the lowest vaginal pH during the period of highest estrogen. However, the vaginal pH of non-human mammals is never as low as is typical for humans (median vaginal pH in humans = 4.5; range of pH across all 21 non-human mammals = 5.4-7.8). Contrary to disease and obstetric risk hypotheses, we found no significant relationship between vaginal pH or lactobacilli relative abundance and multiple metrics of STD or birth injury risk ( P -values ranged from 0.13 to 0.99). Given the lack of evidence for these hypotheses, we discuss two alternative explanations: the common function hypothesis and a novel hypothesis related to the diet of agricultural humans. Specifically, with regard to diet we propose that high levels of starch in human diets have led to increased levels of glycogen in the vaginal tract, which, in turn, promotes the proliferation of lactobacilli. If true, human diet may have paved the way for a novel, protective microbiome in human vaginal tracts. Overall, our results highlight the need for continuing research on non

  8. Carbon-carbon cylinder block

    NASA Technical Reports Server (NTRS)

    Ransone, Philip O. (Inventor)

    1995-01-01

    A lightweight cylinder block composed of carbon-carbon is disclosed. The use of carbon-carbon over conventional materials, such as cast iron or aluminum, reduces the weight of the cylinder block and improves thermal efficiency of the internal combustion reciprocating engine. Due to the negligible coefficient of thermal expansion and unique strength at elevated temperatures of carbon-carbon, the piston-to-cylinder wall clearance can be small, especially when the carbon-carbon cylinder block is used in conjunction with a carbon-carbon piston. Use of the carbon-carbon cylinder has the effect of reducing the weight of other reciprocating engine components allowing the piston to run at higher speeds and improving specific engine performance.

  9. Clothing factors and vaginitis.

    PubMed

    Heidrich, F E; Berg, A O; Bergman, J J

    1984-10-01

    Associations of clothing factors and vulvovaginal symptoms, signs, and microbiology were sought in 203 women seeking care at a university family medicine clinic. Clothing factors studied were use of panty hose, underwear for sleep, cotton lining panels, and pants vs skirts. Women wearing and not wearing panty hose had similar rates of vaginitis symptoms and signs, but yeast vaginitis was about three times more common among wearers. Relationships of other clothing factors to vaginitis were not found. Nonspecific vaginitis was not found to be related to clothing.

  10. The interaction between vaginal microbiota, cervical length, and vaginal progesterone treatment for preterm birth risk.

    PubMed

    Kindinger, Lindsay M; Bennett, Phillip R; Lee, Yun S; Marchesi, Julian R; Smith, Ann; Cacciatore, Stefano; Holmes, Elaine; Nicholson, Jeremy K; Teoh, T G; MacIntyre, David A

    2017-01-19

    Preterm birth is the primary cause of infant death worldwide. A short cervix in the second trimester of pregnancy is a risk factor for preterm birth. In specific patient cohorts, vaginal progesterone reduces this risk. Using 16S rRNA gene sequencing, we undertook a prospective study in women at risk of preterm birth (n = 161) to assess (1) the relationship between vaginal microbiota and cervical length in the second trimester and preterm birth risk and (2) the impact of vaginal progesterone on vaginal bacterial communities in women with a short cervix. Lactobacillus iners dominance at 16 weeks of gestation was significantly associated with both a short cervix <25 mm (n = 15, P < 0.05) and preterm birth <34 +0  weeks (n = 18; P < 0.01; 69% PPV). In contrast, Lactobacillus crispatus dominance was highly predictive of term birth (n = 127, 98% PPV). Cervical shortening and preterm birth were not associated with vaginal dysbiosis. A longitudinal characterization of vaginal microbiota (<18, 22, 28, and 34 weeks) was then undertaken in women receiving vaginal progesterone (400 mg/OD, n = 25) versus controls (n = 42). Progesterone did not alter vaginal bacterial community structure nor reduce L. iners-associated preterm birth (<34 weeks). L. iners dominance of the vaginal microbiota at 16 weeks of gestation is a risk factor for preterm birth, whereas L. crispatus dominance is protective against preterm birth. Vaginal progesterone does not appear to impact the pregnancy vaginal microbiota. Patients and clinicians who may be concerned about "infection risk" associated with the use of a vaginal pessary during high-risk pregnancy can be reassured.

  11. Proficiency-based cervical cancer brachytherapy training.

    PubMed

    Zhao, Sherry; Francis, Louise; Todor, Dorin; Fields, Emma C

    2018-04-25

    Although brachytherapy increases the local control rate for cervical cancer, there has been a progressive decline in its use. Furthermore, the training among residency programs for gynecologic brachytherapy varies considerably, with some residents receiving little to no training. This trend is especially concerning given the association between poor applicator placement and decline in local control. Considering the success of proficiency-based training in other procedural specialties, we developed and implemented a proficiency-based cervical brachytherapy training curriculum for our residents. Each resident placed tandem and ovoid applicators with attending guidance and again alone 2 weeks later using a pelvic model that was modified to allow for cervical brachytherapy. Plain films were taken of the pelvic model, and applicator placement quality was evaluated. Other evaluated metrics included retention of key procedural details, the time taken for each procedure and presession and postsession surveys to assess confidence. During the initial session, residents on average met 4.5 of 5 placement criteria, which improved to 5 the second session. On average, residents were able to remember 7.6 of the 8 key procedural steps. Execution time decreased by an average of 10.5%. Resident confidence with the procedure improved dramatically, from 2.6 to 4.6 of 5. Residents who had previously never performed a tandem and ovoid procedure showed greater improvements in these criteria than those who had. All residents strongly agreed that the training was helpful and wanted to participate again the following year. Residents participating in this simulation training had measurable improvements in the time to perform the procedure, applicator placement quality, and confidence. This curriculum is easy to implement and is of great value for training residents, and would be particularly beneficial in programs with low volume of cervical brachytherapy cases. Simulation programs could

  12. Effect of vaginal or systemic estrogen on dynamics of collagen assembly in the rat vaginal wall.

    PubMed

    Montoya, T Ignacio; Maldonado, P Antonio; Acevedo, Jesus F; Word, R Ann

    2015-02-01

    The objective of this study was to compare the effects of systemic and local estrogen treatment on collagen assembly and biomechanical properties of the vaginal wall. Ovariectomized nulliparous rats were treated with estradiol or conjugated equine estrogens (CEEs) either systemically, vaginal CEE, or vaginal placebo cream for 4 wk. Low-dose local CEE treatment resulted in increased vaginal epithelial thickness and significant vaginal growth without uterine hyperplasia. Furthermore, vaginal wall distensibility increased without compromise of maximal force at failure. Systemic estradiol resulted in modest increases in collagen type I with no change in collagen type III mRNA. Low-dose vaginal treatment, however, resulted in dramatic increases in both collagen subtypes whereas moderate and high dose local therapies were less effective. Consistent with the mRNA results, low-dose vaginal estrogen resulted in increased total and cross-linked collagen content. The inverse relationship between vaginal dose and collagen expression may be explained in part by progressive downregulation of estrogen receptor-alpha mRNA with increasing estrogen dose. We conclude that, in this menopausal rat model, local estrogen treatment increased total and cross-linked collagen content and markedly stimulated collagen mRNA expression in an inverse dose-effect relationship. High-dose vaginal estrogen resulted in downregulation of estrogen receptor-alpha and loss of estrogen-induced increases in vaginal collagen. These results may have important clinical implications regarding the use of local vaginal estrogen therapy and its role as an adjunctive treatment in women with loss of vaginal support. © 2015 by the Society for the Study of Reproduction, Inc.

  13. [Why is brachytherapy still essential in 2017?

    PubMed

    Haie-Méder, C; Maroun, P; Fumagalli, I; Lazarescu, I; Dumas, I; Martinetti, F; Chargari, C

    2018-05-16

    These recent years, brachytherapy has benefited from imaging modalities advances. A more systematic use of tomodensitometric, ultrasonographic and MRI images during brachytherapy procedures has allowed an improvement in target and organs at risk assessment as well as their relationship with the applicators. New concepts integrating tumor regression during treatment have been defined and have been clinically validated. New applicators have been developed and are commercially available. Optimization processes have been developed, integrating hypofractionation modalities leading to tumor control improvement. All these opportunities led to further development of brachytherapy, with indisputable ballistic advantages, especially compared to external irradiation. Copyright © 2018. Published by Elsevier SAS.

  14. MO-D-BRD-00: Electronic Brachytherapy

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    NONE

    Electronic brachytherapy (eBT) has seen an insurgence of manufacturers entering the US market for use in radiation therapy. In addition to the established interstitial, intraluminary, and intracavitary applications of eBT, many centers are now using eBT to treat skin lesions. It is important for medical physicists working with electronic brachytherapy sources to understand the basic physics principles of the sources themselves as well as the variety of applications for which they are being used. The calibration of the sources is different from vendor to vendor and the traceability of calibrations has evolved as new sources came to market. In 2014,more » a new air-kerma based standard was introduced by the National Institute of Standards and Technology (NIST) to measure the output of an eBT source. Eventually commercial treatment planning systems should accommodate this new standard and provide NIST traceability to the end user. The calibration and commissioning of an eBT system is unique to its application and typically entails a list of procedural recommendations by the manufacturer. Commissioning measurements are performed using a variety of methods, some of which are modifications of existing AAPM Task Group protocols. A medical physicist should be familiar with the different AAPM Task Group recommendations for applicability to eBT and how to properly adapt them to their needs. In addition to the physical characteristics of an eBT source, the photon energy is substantially lower than from HDR Ir-192 sources. Consequently, tissue-specific dosimetry and radiobiological considerations are necessary when comparing these brachytherapy modalities and when making clinical decisions as a radiation therapy team. In this session, the physical characteristics and calibration methodologies of eBt sources will be presented as well as radiobiology considerations and other important clinical considerations. Learning Objectives: To understand the basic principles of

  15. Methods for prostate stabilization during transperineal LDR brachytherapy.

    PubMed

    Podder, Tarun; Sherman, Jason; Rubens, Deborah; Messing, Edward; Strang, John; Ng, Wan-Sing; Yu, Yan

    2008-03-21

    In traditional prostate brachytherapy procedures for a low-dose-rate (LDR) radiation seed implant, stabilizing needles are first inserted to provide some rigidity and support to the prostate. Ideally this will provide better seed placement and an overall improved treatment. However, there is much speculation regarding the effectiveness of using regular brachytherapy needles as stabilizers. In this study, we explored the efficacy of two types of needle geometries (regular brachytherapy needle and hooked needle) and several clinically feasible configurations of the stabilization needles. To understand and assess the prostate movement during seed implantation, we collected in vivo data from patients during actual brachytherapy procedures. In vitro experimentation with tissue-equivalent phantoms allowed us to further understand the mechanics behind prostate stabilization. We observed superior stabilization with the hooked needles compared to the regular brachytherapy needles (more than 40% in bilateral parallel needle configuration). Prostate movement was also reduced significantly when regular brachytherapy needles were in an angulated configuration as compared to the parallel configuration (more than 60%). When the hooked needles were angulated for stabilization, further reduction in prostate displacement was observed. In general, for convenience of dosimetric planning and to avoid needle collision, all needles are desired to be in a parallel configuration. In this configuration, hooked needles provide improved stabilization of the prostate. On the other hand, both regular and hooked needles appear to be equally effective in reducing prostate movement when they are in angulated configurations, which will be useful in seed implantation using a robotic system. We have developed nonlinear spring-damper model for the prostate movement which can be used for adapting dosimetric planning during brachytherapy as well as for developing more realistic haptic devices and

  16. Percutaneous interstitial brachytherapy for adrenal metastasis: technical report.

    PubMed

    Kishi, Kazushi; Tamura, Shinji; Mabuchi, Yasushi; Sonomura, Tetsuo; Noda, Yasutaka; Nakai, Motoki; Sato, Morio; Ino, Kazuhiko; Yamanaka, Noboru

    2012-09-01

    We developed and evaluated the feasibility of a brachytherapy technique as a safe and effective treatment for adrenal metastasis. Adapting a paravertebral insertion technique in radiofrequency ablation of adrenal tumors, we developed an interstitial brachytherapy for adrenal metastasis achievable on an outpatient basis. Under local anesthesia and under X-ray CT guidance, brachytherapy applicator needles were percutaneously inserted into the target. A treatment plan was created to eradicate the tumor while preserving normal organs including the spinal cord and kidney. We applied this interstitial brachytherapy technique to two patients: one who developed adrenal metastasis as the third recurrence of uterine cervical cancer after reirradiation, and one who developed metachronous multiple metastases from malignant melanoma. The whole procedure was completed in 2.5 hours. There were no procedure-related or radiation-related early/late complications. FDG PET-CT images at two and three months after treatment showed absence of FDG uptake, and no recurrence of the adrenal tumor was observed for over seven months until expiration, and for six months until the present, respectively. This interventional interstitial brachytherapy procedure may be useful as a safe and eradicative treatment for adrenal metastasis.

  17. Assisted Vaginal Delivery

    MedlinePlus

    ... Patient Education FAQs Assisted Vaginal Delivery Patient Education Pamphlets - Spanish Assisted Vaginal Delivery FAQ192, February 2016 PDF ... on Patient Safety For Patients Patient FAQs Spanish Pamphlets Teen Health About ACOG About Us Leadership & Governance ...

  18. Vaginal estrogen: a dual-edged sword in postoperative healing of the vaginal wall.

    PubMed

    Ripperda, Christopher M; Maldonado, Pedro Antonio; Acevedo, Jesus F; Keller, Patrick W; Akgul, Yucel; Shelton, John M; Word, Ruth Ann

    2017-07-01

    Reconstructive surgery for pelvic organ prolapse is plagued with high failure rates possibly due to impaired healing or regeneration of the vaginal wall. Here, we tested the hypothesis that postoperative administration of local estrogen, direct injection of mesenchymal stem cells (MSCs), or both lead to improved wound healing of the injured vagina in a menopausal rat model. Ovariectomized rats underwent surgical injury to the posterior vaginal wall and were randomized to treatment with placebo (n = 41), estrogen cream (n = 47), direct injection of MSCs (n = 39), or both (n = 43). MSCs did not survive after injection and had no appreciable effects on healing of the vaginal wall. Acute postoperative administration of vaginal estrogen altered the response of the vaginal wall to injury with decreased stiffness, decreased collagen content, and decreased expression of transcripts for matrix components in the stromal compartment. Conversely, vaginal estrogen resulted in marked proliferation of the epithelial layer and increased expression of genes related to epithelial barrier function and protease inhibition. Transcripts for genes involved in chronic inflammation and adaptive immunity were also down-regulated in the estrogenized epithelium. Collectively, these data indicate that, in contrast to the reported positive effects of preoperative estrogen on the uninjured vagina, acute administration of postoperative vaginal estrogen has adverse effects on the early phase of healing of the stromal layer. In contrast, postoperative estrogen plays a positive role in healing of the vaginal epithelium after injury.

  19. Vaginal estrogen: a dual-edged sword in postoperative healing of the vaginal wall

    PubMed Central

    Ripperda, Christopher M.; Maldonado, Pedro Antonio; Acevedo, Jesus F.; Keller, Patrick W.; Akgul, Yucel; Shelton, John M.; Word, Ruth Ann

    2017-01-01

    Abstract Objective: Reconstructive surgery for pelvic organ prolapse is plagued with high failure rates possibly due to impaired healing or regeneration of the vaginal wall. Here, we tested the hypothesis that postoperative administration of local estrogen, direct injection of mesenchymal stem cells (MSCs), or both lead to improved wound healing of the injured vagina in a menopausal rat model. Methods: Ovariectomized rats underwent surgical injury to the posterior vaginal wall and were randomized to treatment with placebo (n = 41), estrogen cream (n = 47), direct injection of MSCs (n = 39), or both (n = 43). Results: MSCs did not survive after injection and had no appreciable effects on healing of the vaginal wall. Acute postoperative administration of vaginal estrogen altered the response of the vaginal wall to injury with decreased stiffness, decreased collagen content, and decreased expression of transcripts for matrix components in the stromal compartment. Conversely, vaginal estrogen resulted in marked proliferation of the epithelial layer and increased expression of genes related to epithelial barrier function and protease inhibition. Transcripts for genes involved in chronic inflammation and adaptive immunity were also down-regulated in the estrogenized epithelium. Conclusions: Collectively, these data indicate that, in contrast to the reported positive effects of preoperative estrogen on the uninjured vagina, acute administration of postoperative vaginal estrogen has adverse effects on the early phase of healing of the stromal layer. In contrast, postoperative estrogen plays a positive role in healing of the vaginal epithelium after injury. PMID:28169915

  20. Enhancement of polarizabilities of cylinders with cylinder-slab resonances

    PubMed Central

    Xiao, Meng; Huang, Xueqin; Liu, H.; Chan, C. T.

    2015-01-01

    If an object is very small in size compared with the wavelength of light, it does not scatter light efficiently. It is hence difficult to detect a very small object with light. We show using analytic theory as well as full wave numerical calculation that the effective polarizability of a small cylinder can be greatly enhanced by coupling it with a superlens type metamaterial slab. This kind of enhancement is not due to the individual resonance effect of the metamaterial slab, nor due to that of the object, but is caused by a collective resonant mode between the cylinder and the slab. We show that this type of particle-slab resonance which makes a small two-dimensional object much “brighter” is actually closely related to the reverse effect known in the literature as “cloaking by anomalous resonance” which can make a small cylinder undetectable. We also show that the enhancement of polarizability can lead to strongly enhanced electromagnetic forces that can be attractive or repulsive, depending on the material properties of the cylinder. PMID:25641391

  1. Anaesthesia Gas Supply: Gas Cylinders

    PubMed Central

    Srivastava, Uma

    2013-01-01

    Invention of oxygen cylinder was one of the most important developments in the field of medical practice. Oxygen and other gases were compressed and stored at high pressure in seamless containers constructed from hand-forged steel in1880. Materials technology has continued to evolve and now medical gas cylinders are generally made of steel alloys or aluminum. The filling pressure as well as capacity has increased considerably while at the same time the weight of cylinders has reduced. Today oxygen cylinder of equivalent size holds a third more oxygen but weighs about 20 kg less. The cylinders are of varying sizes and are color coded. They are tested at regular intervals by the manufacturer using hydraulic, impact, and tensile tests. The top end of the cylinder is fitted with a valve with a variety of number and markings stamped on it. Common valve types include: Pin index valve, bull nose, hand wheel and integral valve. The type of valve varies with cylinder size. Small cylinders have a pin index valve while large have a bull nose type. Safety features in the cylinder are: Color coding, pin index, pressure relief device, Bodok seal, and label attached etc., Safety rules and guidelines must be followed during storage, installation and use of cylinders to ensure safety of patients, hospital personnel and the environment. PMID:24249883

  2. Anaesthesia gas supply: gas cylinders.

    PubMed

    Srivastava, Uma

    2013-09-01

    Invention of oxygen cylinder was one of the most important developments in the field of medical practice. Oxygen and other gases were compressed and stored at high pressure in seamless containers constructed from hand-forged steel in1880. Materials technology has continued to evolve and now medical gas cylinders are generally made of steel alloys or aluminum. The filling pressure as well as capacity has increased considerably while at the same time the weight of cylinders has reduced. Today oxygen cylinder of equivalent size holds a third more oxygen but weighs about 20 kg less. The cylinders are of varying sizes and are color coded. They are tested at regular intervals by the manufacturer using hydraulic, impact, and tensile tests. The top end of the cylinder is fitted with a valve with a variety of number and markings stamped on it. Common valve types include: Pin index valve, bull nose, hand wheel and integral valve. The type of valve varies with cylinder size. Small cylinders have a pin index valve while large have a bull nose type. Safety features in the cylinder are: Color coding, pin index, pressure relief device, Bodok seal, and label attached etc., Safety rules and guidelines must be followed during storage, installation and use of cylinders to ensure safety of patients, hospital personnel and the environment.

  3. Lung tumor motion prediction during lung brachytherapy using finite element model

    NASA Astrophysics Data System (ADS)

    Shirzadi, Zahra; Sadeghi Naini, Ali; Samani, Abbas

    2012-02-01

    A biomechanical model is proposed to predict deflated lung tumor motion caused by diaphragm respiratory motion. This model can be very useful for targeting the tumor in tumor ablative procedures such as lung brachytherapy. To minimize motion within the target lung, these procedures are performed while the lung is deflated. However, significant amount of tissue deformation still occurs during respiration due to the diaphragm contact forces. In the absence of effective realtime image guidance, biomechanical models can be used to estimate tumor motion as a function of diaphragm's position. To develop this model, Finite Element Method (FEM) was employed. To demonstrate the concept, we conducted an animal study of an ex-vivo porcine deflated lung with a tumor phantom. The lung was deformed by compressing a diaphragm mimicking cylinder against it. Before compression, 3D-CT image of this lung was acquired, which was segmented and turned into FE mesh. The lung tissue was modeled as hyperelastic material with a contact loading to calculate the lung deformation and tumor motion during respiration. To validate the results from FE model, the motion of a small area on the surface close to the tumor was tracked while the lung was being loaded by the cylinder. Good agreement was demonstrated between the experiment results and simulation results. Furthermore, the impact of tissue hyperelastic parameters uncertainties in the FE model was investigated. For this purpose, we performed in-silico simulations with different hyperelastic parameters. This study demonstrated that the FEM was accurate and robust for tumor motion prediction.

  4. Lactobacilli Dominance and Vaginal pH: Why Is the Human Vaginal Microbiome Unique?

    PubMed Central

    Miller, Elizabeth A.; Beasley, DeAnna E.; Dunn, Robert R.; Archie, Elizabeth A.

    2016-01-01

    The human vaginal microbiome is dominated by bacteria from the genus Lactobacillus, which create an acidic environment thought to protect women against sexually transmitted pathogens and opportunistic infections. Strikingly, lactobacilli dominance appears to be unique to humans; while the relative abundance of lactobacilli in the human vagina is typically >70%, in other mammals lactobacilli rarely comprise more than 1% of vaginal microbiota. Several hypotheses have been proposed to explain humans' unique vaginal microbiota, including humans' distinct reproductive physiology, high risk of STDs, and high risk of microbial complications linked to pregnancy and birth. Here, we test these hypotheses using comparative data on vaginal pH and the relative abundance of lactobacilli in 26 mammalian species and 50 studies (N = 21 mammals for pH and 14 mammals for lactobacilli relative abundance). We found that non-human mammals, like humans, exhibit the lowest vaginal pH during the period of highest estrogen. However, the vaginal pH of non-human mammals is never as low as is typical for humans (median vaginal pH in humans = 4.5; range of pH across all 21 non-human mammals = 5.4–7.8). Contrary to disease and obstetric risk hypotheses, we found no significant relationship between vaginal pH or lactobacilli relative abundance and multiple metrics of STD or birth injury risk (P-values ranged from 0.13 to 0.99). Given the lack of evidence for these hypotheses, we discuss two alternative explanations: the common function hypothesis and a novel hypothesis related to the diet of agricultural humans. Specifically, with regard to diet we propose that high levels of starch in human diets have led to increased levels of glycogen in the vaginal tract, which, in turn, promotes the proliferation of lactobacilli. If true, human diet may have paved the way for a novel, protective microbiome in human vaginal tracts. Overall, our results highlight the need for continuing research on non

  5. Gas Cylinder Safety, Course 9518

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Glass, George

    2016-10-27

    This course, Gas Cylinder Safety (#9518), presents an overview of the hazards and controls associated with handling, storing, using, and transporting gas cylinders. Standard components and markings of gas cylinders are also presented, as well as the process for the procurement, delivery, and return of gas cylinders at Los Alamos National Laboratory (LANL).

  6. True vaginal prolapse in a bitch.

    PubMed

    Alan, M; Cetin, Y; Sendag, S; Eski, F

    2007-08-01

    Frequently, vaginal fold prolapse is the protrusion of edematous vaginal tissue into and through the opening of the vulva occurring during proestrus and estrus stages of the sexual cycle. True vaginal prolapse may occur near parturition, as the concentration of serum progesterone declines and the concentration of serum oestrogen increases. In the bitch, this type of true vaginal prolapse is a very rare condition. This short communication describes a 5-year-old female, cross-breed dog in moderate condition, weighing 33 kg, with distocia and true vaginal prolapse. Abdominal palpation and transabdominal ultrasonography revealed live and dead foetuses in the uterine horns. One dead and four live fetuses were removed from uterus by cesarean section. The ovariohysterectomy was performed after repositioning the vaginal wall with a combination of traction from within the abdomen and external manipulation through the vulva. Re-occurrence of a vaginal prolapse was not observed and the bitch recovered completely after the surgical therapy. Compared to other vaginal disorders, vaginal prolapse is an uncommon condition in the bitch. In the present case, extreme tenesmus arising from distocia may have predisposed to the vaginal prolapse. The cause of dystocia was probably the disposition of the first foetus. We concluded that the vaginal prolapse was the result of dystocia in the present case.

  7. Dosimetric characterization and output verification for conical brachytherapy surface applicators. Part I. Electronic brachytherapy source

    PubMed Central

    Fulkerson, Regina K.; Micka, John A.; DeWerd, Larry A.

    2014-01-01

    Purpose: Historically, treatment of malignant surface lesions has been achieved with linear accelerator based electron beams or superficial x-ray beams. Recent developments in the field of brachytherapy now allow for the treatment of surface lesions with specialized conical applicators placed directly on the lesion. Applicators are available for use with high dose rate (HDR) 192Ir sources, as well as electronic brachytherapy sources. Part I of this paper will discuss the applicators used with electronic brachytherapy sources; Part II will discuss those used with HDR 192Ir sources. Although the use of these applicators has gained in popularity, the dosimetric characteristics including depth dose and surface dose distributions have not been independently verified. Additionally, there is no recognized method of output verification for quality assurance procedures with applicators like these. Existing dosimetry protocols available from the AAPM bookend the cross-over characteristics of a traditional brachytherapy source (as described by Task Group 43) being implemented as a low-energy superficial x-ray beam (as described by Task Group 61) as observed with the surface applicators of interest. Methods: This work aims to create a cohesive method of output verification that can be used to determine the dose at the treatment surface as part of a quality assurance/commissioning process for surface applicators used with HDR electronic brachytherapy sources (Part I) and 192Ir sources (Part II). Air-kerma rate measurements for the electronic brachytherapy sources were completed with an Attix Free-Air Chamber, as well as several models of small-volume ionization chambers to obtain an air-kerma rate at the treatment surface for each applicator. Correction factors were calculated using MCNP5 and EGSnrc Monte Carlo codes in order to determine an applicator-specific absorbed dose to water at the treatment surface from the measured air-kerma rate. Additionally, relative dose

  8. Dinoprostone vaginal insert versus intravenous oxytocin to reduce postpartum blood loss following vaginal or cesarean delivery.

    PubMed

    Ozalp, E; Tanir, H M; Sener, T

    2010-01-01

    To compare the impact of a dinoprostone vaginal insert and intravenous oxytocin in reducing blood loss of women undergoing vaginal or cesarean delivery. This study was conducted among term singleton pregnancies delivered vaginally or by elective cesarean section. In the vaginally delivered cases, active management of the third stage of labor was conducted. During cesarean delivery, 20 IU of intravenous oxytocin was administered. Women, who either delivered via the vaginal or abdominal route, were then randomly allocated to receive 10 mg vaginal dinoprostone insert for 12 hours (group I, n: 100) or intravenous oxytocin (group II, n: 100), respectively. Mean blood loss and need for additional uterotonics and postpartum hemoglobin and hematocrit levels at 24 and 36 hours after delivery did not differ between the two groups. Women allocated to the dinoprostone vaginal insert arm experienced more nausea and vomiting. Dinoprostone vaginal insert was as effective as intravenous oxytocin in the prevention of postpartum blood loss.

  9. A novel applicator design for intracavitary brachytherapy of the nasopharynx: Simulated reconstruction, image-guided adaptive brachytherapy planning, and dosimetry.

    PubMed

    Bacorro, Warren R; Agas, Ryan Anthony F; Cabrera, Stellar Marie R; Bojador, Maureen R; Sogono, Paolo G; Mejia, Michael Benedict A; Sy Ortin, Teresa T

    2018-05-11

    In nasopharyngeal cancer, brachytherapy is given as boost in primary treatment or as salvage for recurrent or persistent disease. The Rotterdam nasopharyngeal applicator (RNA) allows for suboptimal reduction of soft palate radiation dose, based on image-guided brachytherapy plans. Building on the RNA, we propose a novel design, the Benavides nasopharyngeal applicator (BNA). The virtual BNA was reconstructed on two cases (one T1, one T2) previously treated with intracavitary brachytherapy using the RNA. Dose was prescribed to the high-risk clinical target volumes (CTVs) and optimization was such that high-risk CTV D90 ≥ 100% of prescribed dose (PD), intermediate-risk-CTV D90 ≥ 75% PD, and soft palate D2cc ≤ 120% PD. The optimized RNA and BNA image-guided brachytherapy plans were compared in terms of CTV coverage and organs-at-risk sparing. Optimization objectives were more easily met with the BNA. For the T1 case, all three planning objectives were easily achieved in both the RNA and BNA, but with 18-19% lower soft palate doses with the BNA. For the T2 case, the CTV planning objectives were achieved in both the RNA and BNA, but the soft palate constraint was only achieved with the BNA, with 38-41% lower soft palate doses. Compared to the RNA, the BNA permits easier optimization and improves therapeutic ratio by a significant reduction of soft palate doses, based on simulation using a proposed system for CTV/organs-at-risk delineation, prescription, and optimization for image-guided adaptive brachytherapy. Clinical piloting using a prototype is necessary to evaluate its feasibility and utility. Copyright © 2018 American Brachytherapy Society. Published by Elsevier Inc. All rights reserved.

  10. Evaluation of vaginal complaints.

    PubMed

    Anderson, Matthew R; Klink, Kathleen; Cohrssen, Andreas

    2004-03-17

    Vaginal symptoms are one of the most common reasons for gynecological consultation. Clinicians have traditionally diagnosed vaginal candidiasis, bacterial vaginosis, and vaginal trichomoniasis using some combination of physical examination, pH, the wet mount, and the whiff test. To evaluate the role of the clinical examination and determine the positive and negative likelihood ratios (LRs) for the diagnosis of vaginal candidiasis, bacterial vaginosis, and vaginal trichomoniasis. Using a structured literature review, we abstracted information on sensitivity and specificity for symptoms, signs, and office laboratory procedures. We chose published (1966 to April 2003) articles that appeared in the MEDLINE database and were indexed under the combined search terms of diagnosis with vaginitis, vaginal discharge, candidiasis, bacterial vaginosis, and trichomoniasis. Included studies of symptomatic premenopausal women seen in primary care settings. Tests were evaluated only if they would provide diagnostic information during the office visit and were compared with an acceptable criterion standard. All 3 authors extracted the data and computed sensitivity and specificity from each article independently. The absence of standard definitions for symptoms and signs made it impossible to combine results across studies. Symptoms alone do not allow clinicians to distinguish confidently between the causes of vaginitis. However, a patient's lack of itching makes candidiasis less likely (range of LRs, 0.18 [95% confidence interval [CI], 0.05-0.70] to 0.79 [95% CI, 0.72-0.87]) and lack of perceived odor makes bacterial vaginosis unlikely (LR, 0.07 [95% CI, 0.01-0.51]). Similarly, physical examination signs are limited in their diagnostic power. The presence of inflammatory signs is associated with candidiasis (range of LRs, 2.1 [95% CI, 1.5-2.8] to 8.4 [95% CI, 2.3-31]). Presence of a "high cheese" odor on examination is predictive of bacterial vaginosis (LR, 3.2 [95% CI, 2

  11. Application of the MCNP5 code to the Modeling of vaginal and intra-uterine applicators used in intracavitary brachytherapy: a first approach

    NASA Astrophysics Data System (ADS)

    Gerardy, I.; Rodenas, J.; Van Dycke, M.; Gallardo, S.; Tondeur, F.

    2008-02-01

    Brachytherapy is a radiotherapy treatment where encapsulated radioactive sources are introduced within a patient. Depending on the technique used, such sources can produce high, medium or low local dose rates. The Monte Carlo method is a powerful tool to simulate sources and devices in order to help physicists in treatment planning. In multiple types of gynaecological cancer, intracavitary brachytherapy (HDR Ir-192 source) is used combined with other therapy treatment to give an additional local dose to the tumour. Different types of applicators are used in order to increase the dose imparted to the tumour and to limit the effect on healthy surrounding tissues. The aim of this work is to model both applicator and HDR source in order to evaluate the dose at a reference point as well as the effect of the materials constituting the applicators on the near field dose. The MCNP5 code based on the Monte Carlo method has been used for the simulation. Dose calculations have been performed with *F8 energy deposition tally, taking into account photons and electrons. Results from simulation have been compared with experimental in-phantom dose measurements. Differences between calculations and measurements are lower than 5%.The importance of the source position has been underlined.

  12. Prostate brachytherapy - discharge

    MedlinePlus

    ... chap 84. Read More Prostate brachytherapy Prostate cancer Prostate-specific antigen (PSA) blood test Radical prostatectomy Review Date 2/21/2017 Updated by: Jennifer Sobol, DO, Urologist with the Michigan ... Cancer Browse the Encyclopedia A.D.A.M., ...

  13. Management of vaginal extrusion after tension-free vaginal tape procedure for urodynamic stress incontinence.

    PubMed

    Giri, Subhasis K; Sil, Debasri; Narasimhulu, Girish; Flood, Hugh D; Skehan, Mark; Drumm, John

    2007-06-01

    To report our experience in the management of vaginal extrusion after the tension-free vaginal tape (TVT) procedure for urodynamic stress incontinence. Five patients diagnosed with vaginal extrusion after a TVT procedure performed at our institution were identified. We reviewed the patients' records retrospectively. The interval from TVT placement to diagnosis, presenting symptoms and signs, duration of symptoms, diagnostic test findings, treatment, and postoperative results were recorded. Patients were followed up for at least 12 months. From January 2001 to June 2004, a total of 166 patients underwent the TVT procedure. Of these, 5 patients (3%) were diagnosed with isolated vaginal extrusion 4 to 40 months postoperatively. No cases of urethral or bladder erosion occurred in this series. The symptoms included vaginal discharge, pain, bleeding, and dyspareunia. The eroded margin of the vaginal mucosa was trimmed, mobilized, and closed over the tape with interrupted vertical mattress sutures in a single layer using 2-0 polyglactin 910 to avoid mucosal inversion. All patients remained symptom free without any evidence of defective healing or additional extrusion at a minimal follow-up of 12 months. Primary reclosure of the vaginal mucosa over the TVT tape is an effective first-line treatment option for vaginal extrusion without compromising continence. Patients undergoing the TVT procedure should be adequately counseled about the possibility of this complication and the available treatment options.

  14. Vaginitis: current microbiologic and clinical concepts.

    PubMed Central

    Hill, L V; Embil, J A

    1986-01-01

    Infectious vaginitis occurs when the normal vaginal flora is disrupted; it may arise when saprophytes overwhelm the host immune response, when pathogenic organisms are introduced into the vagina or when changes in substrate allow an imbalance of microorganisms to develop. Examples of these types of vaginitis include the presence of chronic fungal infection in women with an inadequate cellular immune response to the yeast, the introduction of trichomonads into vaginal epithelium that has a sufficient supply of glycogen, and the alteration in bacterial flora, normally dominated by Lactobacillus spp., and its metabolites that is characteristic of "nonspecific vaginitis". The authors review microbiologic and clinical aspects of the fungal, protozoal and bacterial infections, including the interactions of bacteria thought to produce nonspecific vaginitis, that are now recognized as causing vaginitis. Other causes of vaginitis are also discussed. PMID:3510698

  15. Vaginitis: current microbiologic and clinical concepts.

    PubMed

    Hill, L V; Embil, J A

    1986-02-15

    Infectious vaginitis occurs when the normal vaginal flora is disrupted; it may arise when saprophytes overwhelm the host immune response, when pathogenic organisms are introduced into the vagina or when changes in substrate allow an imbalance of microorganisms to develop. Examples of these types of vaginitis include the presence of chronic fungal infection in women with an inadequate cellular immune response to the yeast, the introduction of trichomonads into vaginal epithelium that has a sufficient supply of glycogen, and the alteration in bacterial flora, normally dominated by Lactobacillus spp., and its metabolites that is characteristic of "nonspecific vaginitis". The authors review microbiologic and clinical aspects of the fungal, protozoal and bacterial infections, including the interactions of bacteria thought to produce nonspecific vaginitis, that are now recognized as causing vaginitis. Other causes of vaginitis are also discussed.

  16. Effect of Vaginal or Systemic Estrogen on Dynamics of Collagen Assembly in the Rat Vaginal Wall1

    PubMed Central

    Montoya, T. Ignacio; Maldonado, P. Antonio; Acevedo, Jesus F.; Word, R. Ann

    2014-01-01

    ABSTRACT The objective of this study was to compare the effects of systemic and local estrogen treatment on collagen assembly and biomechanical properties of the vaginal wall. Ovariectomized nulliparous rats were treated with estradiol or conjugated equine estrogens (CEEs) either systemically, vaginal CEE, or vaginal placebo cream for 4 wk. Low-dose local CEE treatment resulted in increased vaginal epithelial thickness and significant vaginal growth without uterine hyperplasia. Furthermore, vaginal wall distensibility increased without compromise of maximal force at failure. Systemic estradiol resulted in modest increases in collagen type I with no change in collagen type III mRNA. Low-dose vaginal treatment, however, resulted in dramatic increases in both collagen subtypes whereas moderate and high dose local therapies were less effective. Consistent with the mRNA results, low-dose vaginal estrogen resulted in increased total and cross-linked collagen content. The inverse relationship between vaginal dose and collagen expression may be explained in part by progressive downregulation of estrogen receptor-alpha mRNA with increasing estrogen dose. We conclude that, in this menopausal rat model, local estrogen treatment increased total and cross-linked collagen content and markedly stimulated collagen mRNA expression in an inverse dose-effect relationship. High-dose vaginal estrogen resulted in downregulation of estrogen receptor-alpha and loss of estrogen-induced increases in vaginal collagen. These results may have important clinical implications regarding the use of local vaginal estrogen therapy and its role as an adjunctive treatment in women with loss of vaginal support. PMID:25537371

  17. Directed shift of vaginal microbiota induced by vaginal application of sucrose gel in rhesus macaques.

    PubMed

    Hu, Kai-tao; Zheng, Jin-xin; Yu, Zhi-jian; Chen, Zhong; Cheng, Hang; Pan, Wei-guang; Yang, Wei-zhi; Wang, Hong-yan; Deng, Qi-wen; Zeng, Zhong-ming

    2015-04-01

    Sucrose gel was used to treat bacterial vaginosis in a phase III clinical trial. However, the changes of vaginal flora after treatment were only examined by Nugent score in that clinical trial, While the vaginal microbiota of rhesus macaques is characterized by anaerobic, Gram-negative bacteria, few lactobacilli, and pH levels above 4.6, similar to the microbiota of patients with bacterial vaginosis. This study is aimed to investigate the change of the vaginal microbiota of rehsus macaques after topical use of sucrose gel to reveal more precisely the bacterial population shift after the topical application of sucrose gel. Sixteen rhesus macaques were treated with 0.5 g sucrose gel vaginally and three with 0.5 g of placebo gel. Vaginal swabs were collected daily following treatment. Vaginal pH levels and Nugent scores were recorded. The composition of the vaginal micotbiota was tested by V3∼V4 16S rDNA metagenomic sequencing. Dynamic changes in the Lactobacillus genus were analyzed by qPCR. The vaginal microbiota of rhesus macaques are dominated by anaerobic Gram-negative bacteria, with few lactobacilli and high pH levels above 4.6. After five days' treatment with topical sucrose gel, the component percentage of Lactobacillus in vaginal microbiota increased from 1.31% to 81.59%, while the component percentage of Porphyromonas decreased from 18.60% to 0.43%, Sneathia decreased from 15.09% to 0.89%, Mobiluncus decreased from 8.23% to 0.12%, etc.. The average vaginal pH values of 16 rhesus macaques of the sucrose gel group decreased from 5.4 to 3.89. There were no significant changes in microbiota and vaginal pH observed in the placebo group. Rhesus macaques can be used as animal models of bacterial vaginosis to develop drugs and test treatment efficacy. Furthermore, the topical application of sucrose gel induced the shifting of vaginal flora of rhesus macaques from a BV kind of flora to a lactobacilli-dominating flora. Copyright © 2015 The Authors. Published by

  18. Fast track vaginal surgery.

    PubMed

    Ottesen, Marianne; Sørensen, Mette; Rasmussen, Yvonne; Smidt-Jensen, Steen; Kehlet, Henrik; Ottesen, Bent

    2002-02-01

    Our aim was to describe the need for postoperative hospitalization after vaginal surgery for utero-vaginal prolapse with well-defined charts for postoperative care. A prospective, descriptive study. Consecutive women admitted for first-time vaginal surgery for utero-vaginal prolapse at a public university hospital in Copenhagen, Denmark, underwent surgery and postoperative care in a fast track setting from September 15, 1999 to June 15 2000. A multimodal rehabilitation model with emphasis on information, standardized general anesthesia, reduced surgical distress, optimized pain-relief, early oral nutrition and ambulation, minimal use of indwelling catheter and vaginal packing. Postoperative hospital stay, complications, re-admission, success rate, patients' satisfaction and acceptability. Forty-one women with a median age of 69 years (range, 44-88 years) were included. All underwent anterior and/or posterior vaginal repair. Nineteen (46.3%) underwent vaginal hysterectomy, and eight (19.5%) underwent the Manchester procedure. Postoperative hospital stay was median 24 hr. Only three (7.3%) were discharged later than 48 hr. No re-admissions occurred. The most frequent complications were urinary retention exceeding 450 ml, and urinary tract infection (12.2%, and 9.8%, respectively). Short-term success rate was 97.6%. Patients' satisfaction rates were 85.4-95.1%. The median score of acceptability was 10 on a 0-10 points scale. The need for postoperative hospitalization was median 24 hr after vaginal surgery in a fast track setting, independently of the complexity of the procedure performed. Short-term success rate, satisfaction rates, and acceptability were all excellent. Follow up has been established to evaluate long-term success rates and recurrence.

  19. Semaphorin 4D induces vaginal epithelial cell apoptosis to control mouse postnatal vaginal tissue remodeling.

    PubMed

    Ito, Takuji; Bai, Tao; Tanaka, Tetsuji; Yoshida, Kenji; Ueyama, Takashi; Miyajima, Masayasu; Negishi, Takayuki; Kawasaki, Takahiko; Takamatsu, Hyota; Kikutani, Hitoshi; Kumanogoh, Atsushi; Yukawa, Kazunori

    2015-02-01

    The opening of the mouse vaginal cavity to the skin is a postnatal tissue remodeling process that occurs at approximately five weeks of age for the completion of female genital tract maturation at puberty. The tissue remodeling process is primarily composed of a hormonally triggered apoptotic process predominantly occurring in the epithelium of the distal section of the vaginal cavity. However, the detailed mechanism underlying the apoptotic induction remains to be elucidated. In the present study, it was observed that the majority of BALB/c mice lacking the class 4 semaphorin, semaphorin 4D (Sema4D), developed imperforate vagina and hydrometrocolpos resulting in a perpetually unopened vaginal cavity regardless of a normal estrogen level comparable with that in wild‑type (WT) mice. Administration of β‑estradiol to infant Sema4D‑deficient (Sema4D‑/‑) mice did not induce precocious vaginal opening, which was observed in WT mice subjected to the same β‑estradiol administration, excluding the possibility that the closed vaginal phenotype was due to insufficient estrogen secretion at the time of vaginal opening. In order to assess the role of Sema4D in the postnatal vaginal tissue remodeling process, the expression of Sema4D and its receptor, plexin‑B1, was examined as well as the level of apoptosis in the vaginal epithelia of five‑week‑old WT and Sema4D‑/‑ mice. Immunohistochemical analyses confirmed the localization of Sema4D and plexin‑B1 in the mouse vaginal epithelia. Terminal deoxynucleotidyl transferase dUTP nick end labeling assay and immunohistochemistry detecting activated caspase‑3 revealed significantly fewer apoptotic cells in situ in the vaginal mucosa of five‑week‑old Sema4D‑/‑ mice compared with WT mice. The addition of recombinant Sema4D to Sema4D‑/‑ vaginal epithelial cells in culture significantly enhanced apoptosis of the vaginal epithelial cells, demonstrating the apoptosis‑inducing activity of Sema4D. The

  20. Semaphorin 4D induces vaginal epithelial cell apoptosis to control mouse postnatal vaginal tissue remodeling

    PubMed Central

    ITO, TAKUJI; BAI, TAO; TANAKA, TETSUJI; YOSHIDA, KENJI; UEYAMA, TAKASHI; MIYAJIMA, MASAYASU; NEGISHI, TAKAYUKI; KAWASAKI, TAKAHIKO; TAKAMATSU, HYOTA; KIKUTANI, HITOSHI; KUMANOGOH, ATSUSHI; YUKAWA, KAZUNORI

    2015-01-01

    The opening of the mouse vaginal cavity to the skin is a postnatal tissue remodeling process that occurs at approximately five weeks of age for the completion of female genital tract maturation at puberty. The tissue remodeling process is primarily composed of a hormonally triggered apoptotic process predominantly occurring in the epithelium of the distal section of the vaginal cavity. However, the detailed mechanism underlying the apoptotic induction remains to be elucidated. In the present study, it was observed that the majority of BALB/c mice lacking the class 4 semaphorin, semaphorin 4D (Sema4D), developed imperforate vagina and hydrometrocolpos resulting in a perpetually unopened vaginal cavity regardless of a normal estrogen level comparable with that in wild-type (WT) mice. Administration of β-estradiol to infant Sema4D-deficient (Sema4D−/−) mice did not induce precocious vaginal opening, which was observed in WT mice subjected to the same β-estradiol administration, excluding the possibility that the closed vaginal phenotype was due to insufficient estrogen secretion at the time of vaginal opening. In order to assess the role of Sema4D in the postnatal vaginal tissue remodeling process, the expression of Sema4D and its receptor, plexin-B1, was examined as well as the level of apoptosis in the vaginal epithelia of five-week-old WT and Sema4D−/− mice. Immunohistochemical analyses confirmed the localization of Sema4D and plexin-B1 in the mouse vaginal epithelia. Terminal deoxynucleotidyl transferase dUTP nick end labeling assay and immunohistochemistry detecting activated caspase-3 revealed significantly fewer apoptotic cells in situ in the vaginal mucosa of five-week-old Sema4D−/− mice compared with WT mice. The addition of recombinant Sema4D to Sema4D−/− vaginal epithelial cells in culture significantly enhanced apoptosis of the vaginal epithelial cells, demonstrating the apoptosis-inducing activity of Sema4D. The experimental reduction of

  1. Bacterial vaginosis, vaginal flora patterns and vaginal hygiene practices in patients presenting with vaginal discharge syndrome in The Gambia, West Africa

    PubMed Central

    Demba, Edward; Morison, Linda; van der Loeff, Maarten Schim; Awasana, Akum A; Gooding, Euphemia; Bailey, Robin; Mayaud, Philippe; West, Beryl

    2005-01-01

    Background Bacterial vaginosis (BV) – a syndrome characterised by a shift in vaginal flora – appears to be particularly common in sub-Saharan Africa, but little is known of the pattern of vaginal flora associated with BV in Africa. We conducted a study aimed at determining the prevalence of BV and patterns of BV-associated vaginal micro-flora among women with vaginal discharge syndrome (VDS) in The Gambia, West Africa. Methods We enrolled 227 women with VDS from a large genito-urinary medicine clinic in Fajara, The Gambia. BV was diagnosed by the Nugent's score and Amsel's clinical criteria. Vaginal swabs were collected for T vaginalis and vaginal flora microscopy, and for Lactobacillus spp, aerobic organisms, Candida spp and BV-associated bacteria (Gardnerella vaginalis, anaerobic bacteria, and Mycoplasma spp) cultures; and cervical swabs were collected for N gonorrhoeae culture and C trachomatis PCR. Sera were tested for HIV-1 and HIV-2 antibodies. Sexual health history including details on sexual hygiene were obtained by standardised questionnaire. Results BV prevalence was 47.6% by Nugent's score and 30.8% by Amsel's clinical criteria. Lactobacillus spp were isolated in 37.8% of women, and 70% of the isolates were hydrogen-peroxide (H202)-producing strains. Prevalence of BV-associated bacteria were: G vaginalis 44.4%; Bacteroides 16.7%; Prevotella 15.2%; Peptostretococcus 1.5%; Mobiluncus 0%; other anaerobes 3.1%; and Mycoplasma hominis 21.4%. BV was positively associated with isolation of G vaginalis (odds-ratio [OR] 19.42, 95%CI 7.91 – 47.6) and anaerobes (P = 0.001 [OR] could not be calculated), but not with M hominis. BV was negatively associated with presence of Lactobacillus (OR 0.07, 95%CI 0.03 – 0.15), and H2O2-producing lactobacilli (OR 0.12, 95% CI 0.05 – 0.28). Presence of H2O2-producing lactobacilli was associated with significantly lower prevalence of G vaginalis, anaerobes and C trachomatis. HIV prevalence was 12.8%. Overall, there was

  2. Heterogeneity of Vaginal Microbial Communities within Individuals▿ #

    PubMed Central

    Kim, Tae Kyung; Thomas, Susan M.; Ho, Mengfei; Sharma, Shobha; Reich, Claudia I.; Frank, Jeremy A.; Yeater, Kathleen M.; Biggs, Diana R.; Nakamura, Noriko; Stumpf, Rebecca; Leigh, Steven R.; Tapping, Richard I.; Blanke, Steven R.; Slauch, James M.; Gaskins, H. Rex; Weisbaum, Jon S.; Olsen, Gary J.; Hoyer, Lois L.; Wilson, Brenda A.

    2009-01-01

    Recent culture-independent studies have revealed that a healthy vaginal ecosystem harbors a surprisingly complex assemblage of microorganisms. However, the spatial distribution and composition of vaginal microbial populations have not been investigated using molecular methods. Here, we evaluated site-specific microbial composition within the vaginal ecosystem and examined the influence of sampling technique in detection of the vaginal microbiota. 16S rRNA gene clone libraries were prepared from samples obtained from different locations (cervix, fornix, outer vaginal canal) and by different methods (swabbing, scraping, lavaging) from the vaginal tracts of eight clinically healthy, asymptomatic women. The data reveal that the vaginal microbiota is not homogenous throughout the vaginal tract but differs significantly within an individual with regard to anatomical site and sampling method used. Thus, this study illuminates the complex structure of the vaginal ecosystem and calls for the consideration of microenvironments when sampling vaginal microbiota as a clinical predictor of vaginal health. PMID:19158255

  3. Effects of a One Year Reusable Contraceptive Vaginal Ring on Vaginal Microflora and the Risk of Vaginal Infection: An Open-Label Prospective Evaluation.

    PubMed

    Huang, Yongmei; Merkatz, Ruth B; Hillier, Sharon L; Roberts, Kevin; Blithe, Diana L; Sitruk-Ware, Régine; Creinin, Mitchell D

    2015-01-01

    A contraceptive vaginal ring (CVR) containing Nestorone® (NES) and ethinyl estradiol (EE) that is reusable for 1- year (13 cycles) is under development. This study assessed effects of this investigational CVR on the incidence of vaginal infections and change in vaginal microflora. There were 120 women enrolled into a NES/EE CVR Phase III trial and a microbiology sub-study for up to 1- year of cyclic product use. Gynecological examinations were conducted at baseline, the first week of cycle 6 and last week of cycle 13 (or during early discontinuation visits). Vaginal swabs were obtained for wet mount microscopy, Gram stain and culture. The CVR was removed from the vagina at the last study visit and cultured. Semi-quantitative cultures for Lactobacillus, Gardnerella vaginalis, Enterococcus faecalis, Staphylococcus aureus, Escherichia coli, anaerobic gram negative rods (GNRs), Candida albicans and other yeasts were performed on vaginal and CVR samples. Vaginal infections were documented throughout the study. Over 1- year of use, 3.3% of subjects were clinically diagnosed with bacterial vaginosis, 15.0% with vulvovaginal candidiasis, and 0.8% with trichomoniasis. The detection rate of these three infections did not change significantly from baseline to either Cycle 6 or 13. Nugent scores remained stable. H2O2-positive Lactobacillus dominated vaginal flora with a non-significant prevalence increase from 76.7% at baseline to 82.7% at cycle 6 and 90.2% at cycle 13, and a median concentration of 107 colony forming units (cfu) per gram. Although anaerobic GNRs prevalence increased significantly, the median concentration decreased slightly (104 to 103cfu per gram). There were no significant changes in frequency or concentrations of other pathogens. High levels of agreement between vaginal and ring surface microbiota were observed. Sustained use of the NES/EE CVR did not increase the risk of vaginal infection and was not disruptive to the vaginal ecosystem. Clinical

  4. Effects of a One Year Reusable Contraceptive Vaginal Ring on Vaginal Microflora and the Risk of Vaginal Infection: An Open-Label Prospective Evaluation

    PubMed Central

    Huang, Yongmei; Merkatz, Ruth B.; Hillier, Sharon L.; Roberts, Kevin; Blithe, Diana L.; Sitruk-Ware, Régine; Creinin, Mitchell D.

    2015-01-01

    Background A contraceptive vaginal ring (CVR) containing Nestorone® (NES) and ethinyl estradiol (EE) that is reusable for 1- year (13 cycles) is under development. This study assessed effects of this investigational CVR on the incidence of vaginal infections and change in vaginal microflora. Methods There were 120 women enrolled into a NES/EE CVR Phase III trial and a microbiology sub-study for up to 1- year of cyclic product use. Gynecological examinations were conducted at baseline, the first week of cycle 6 and last week of cycle 13 (or during early discontinuation visits). Vaginal swabs were obtained for wet mount microscopy, Gram stain and culture. The CVR was removed from the vagina at the last study visit and cultured. Semi-quantitative cultures for Lactobacillus, Gardnerella vaginalis, Enterococcus faecalis, Staphylococcus aureus, Escherichia coli, anaerobic gram negative rods (GNRs), Candida albicans and other yeasts were performed on vaginal and CVR samples. Vaginal infections were documented throughout the study. Results Over 1- year of use, 3.3% of subjects were clinically diagnosed with bacterial vaginosis, 15.0% with vulvovaginal candidiasis, and 0.8% with trichomoniasis. The detection rate of these three infections did not change significantly from baseline to either Cycle 6 or 13. Nugent scores remained stable. H2O2-positive Lactobacillus dominated vaginal flora with a non-significant prevalence increase from 76.7% at baseline to 82.7% at cycle 6 and 90.2% at cycle 13, and a median concentration of 107 colony forming units (cfu) per gram. Although anaerobic GNRs prevalence increased significantly, the median concentration decreased slightly (104 to 103cfu per gram). There were no significant changes in frequency or concentrations of other pathogens. High levels of agreement between vaginal and ring surface microbiota were observed. Conclusion Sustained use of the NES/EE CVR did not increase the risk of vaginal infection and was not disruptive to

  5. [Brachytherapy for head and neck cancers].

    PubMed

    Peiffert, D; Coche-Dequéant, B; Lapeyre, M; Renard, S

    2018-05-29

    The main indications of the brachytherapy of head and neck cancers are the limited tumours of the lip, the nose, the oral cavity and the oropharynx. Nasopharynx tumours are nowadays treated by intensity-modulated radiotherapy. This technique can be exclusive, associated with external radiotherapy or postoperative. It can also be a salvage treatment for the second primaries in previously irradiated areas. If the low dose rate brachytherapy rules remain the reference, the pulse dose rate technique allows the prescription of the dose rate and the optimisation of the dose distribution. Results of high dose rate brachytherapy are now published. This paper reports the recommendations of the Gec-ESTRO, published in 2017, and takes into account the data of the historical low dose rate series, and is upgraded with the pulsed-dose rate and high dose rate series. Copyright © 2018. Published by Elsevier SAS.

  6. Surgical removal of a large vaginal calculus formed after a tension-free vaginal tape procedure.

    PubMed

    Zilberlicht, Ariel; Feiner, Benjamin; Haya, Nir; Auslender, Ron; Abramov, Yoram

    2016-11-01

    Vaginal calculus is a rare disorder which has been reported in association with urethral diverticulum, urogenital sinus anomaly, bladder exstrophy and the tension-free vaginal tape (TVT) procedure. We report a 42-year-old woman who presented with persistent, intractable urinary tract infection (UTI) following a TVT procedure. Cystoscopy demonstrated an eroded tape with the formation of a bladder calculus, and the patient underwent laser cystolithotripsy and cystoscopic resection of the tape. Following this procedure, her UTI completely resolved and she remained asymptomatic for several years. Seven years later she presented with a solid vaginal mass. Pelvic examination followed by transvaginal ultrasonography and magnetic resonance imaging demonstrated a large vaginal calculus located at the lower third of the anterior vaginal wall adjacent to the bladder neck. This video presents the transvaginal excision and removal of the vaginal calculus.

  7. Vaginal Calculus in a Woman With Mixed Urinary Incontinence and Vaginal Mesh Exposure.

    PubMed

    Winkelman, William D; Rabban, Joseph T; Korn, Abner P

    2016-01-01

    Vaginal calculi are extremely rare and are most commonly encountered in the setting of an urethrovaginal or vesicovaginal fistula. We present a case of a 72-year-old woman with mixed urinary incontinence and vaginal mesh exposure incidentally found to have a large vaginal calculus. We removed the calculus surgically and analyzed the components. Results demonstrated the presence of ammonium-magnesium phosphate hexahydrate and carbonate apatite.

  8. Tandem Cylinder Noise Predictions

    NASA Technical Reports Server (NTRS)

    Lockard, David P.; Khorrami, Mehdi R.; CHoudhari, Meelan M.; Hutcheson, Florence V.; Brooks, Thomas F.; Stead, Daniel J.

    2007-01-01

    In an effort to better understand landing-gear noise sources, we have been examining a simplified configuration that still maintains some of the salient features of landing-gear flow fields. In particular, tandem cylinders have been studied because they model a variety of component level interactions. The present effort is directed at the case of two identical cylinders spatially separated in the streamwise direction by 3.7 diameters. Experimental measurements from the Basic Aerodynamic Research Tunnel (BART) and Quiet Flow Facility (QFF) at NASA Langley Research Center (LaRC) have provided steady surface pressures, detailed off-surface measurements of the flow field using Particle Image Velocimetry (PIV), hot-wire measurements in the wake of the rear cylinder, unsteady surface pressure data, and the radiated noise. The experiments were conducted at a Reynolds number of 166 105 based on the cylinder diameter. A trip was used on the upstream cylinder to insure a fully turbulent shedding process and simulate the effects of a high Reynolds number flow. The parallel computational effort uses the three-dimensional Navier-Stokes solver CFL3D with a hybrid, zonal turbulence model that turns off the turbulence production term everywhere except in a narrow ring surrounding solid surfaces. The current calculations further explore the influence of the grid resolution and spanwise extent on the flow and associated radiated noise. Extensive comparisons with the experimental data are used to assess the ability of the computations to simulate the details of the flow. The results show that the pressure fluctuations on the upstream cylinder, caused by vortex shedding, are smaller than those generated on the downstream cylinder by wake interaction. Consequently, the downstream cylinder dominates the noise radiation, producing an overall directivity pattern that is similar to that of an isolated cylinder. Only calculations based on the full length of the model span were able to

  9. Providers' Experiences with Vaginal Dilator Training for Patients with Vaginal Agenesis.

    PubMed

    Patel, Vrunda; Hakim, Julie; Gomez-Lobo, Veronica; Amies Oelschlager, Anne-Marie

    2018-02-01

    To examine providers' experiences with vaginal dilator training for patients with vaginal agenesis. Anonymous electronic survey. Members of the North American Society for Pediatric and Adolescent Gynecology. How providers learn about vaginal dilator training, common techniques, and methods used for patient training, assessment of patient readiness, common patient complaints, issues leading to early discontinuation. There were a total of 55 completed survey responses of which 31 respondents (56%) had been in practice for more than 10 years. Forty-nine were gynecologists (89%), 20 had completed a fellowship in pediatric and adolescent gynecology (36%), and 6 were reproductive endocrinologists (11%). Thirty-one respondents had first learned about vaginal dilator training through lectures (56%) whereas only 9 through mentorship and fellowship (16%). According to respondents, the most common issue leading to early discontinuation was lack of patient motivation and readiness (n = 42; 76%). The most common complication was pain or discomfort (n = 45; 82%). More than half of respondents determined dilator therapy was successful when patients reported comfortable sexual intercourse (n = 30; 55%) and 65% (n = 35) did not delineate any restrictions to initiation of sexual intercourse. Most respondents (87%) requested further vaginal dilator training at either a clinical meeting (n = 26; 47%) or with a training video (n = 22; 40%). Our study in an experienced cohort of pediatric gynecology providers highlights the need for further research and training on vaginal dilation education. Copyright © 2017 North American Society for Pediatric and Adolescent Gynecology. Published by Elsevier Inc. All rights reserved.

  10. Trends in the Utilization of Adjuvant Vaginal Cuff Brachytherapy and/or External Beam Radiation Treatment in Stage I and II Endometrial Cancer: A Surveillance, Epidemiology, and End-Results Study

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Patel, Mehul K.; Cote, Michele L.; Ali-Fehmi, Rouba

    2012-05-01

    Purpose: The optimal adjuvant radiation treatment for endometrial carcinoma (EC) remains controversial. Adjuvant vaginal cuff brachytherapy (VB) has emerged as an increasingly common treatment modality. However, the time trends for using VB, external beam radiation therapy (EBRT), or combined therapy (VB+EBRT) have not been well characterized. We therefore examined the utilization trends of VB, EBRT, and VB+EBRT for adjuvant RT in International Federation of Gynecologic Oncology (FIGO) stage I and II EC over time. Methods and Materials: We evaluated treatment patterns for 48,122 patients with EC diagnosed between January 1995 and December 2005, using the National Cancer Institute's Surveillance, Epidemiology,more » and End Results (SEER) public use database. Chi-squared tests were used to assess differences by radiation type (VB, EBRT, and VB+EBRT) and various demographic and clinical variables. Results: Analyses were limited to 9,815 patients (20.4%) with EC who met the inclusion criteria. Among women who received adjuvant RT, the proportion receiving VB increased yearly (12.9% in 1995 compared to 32.8% in 2005 (p < 0.0001). The increasing use of VB was proportional to the decreasing use of EBRT (56.1% in 1995 to 45.8% in 2005; p < 0.0001) and VB+EBRT (31.0% in 1995 to 21.4% in 2005; p < 0.001). Conclusions: This population-based report demonstrates an increasing trend in the use of VB in the adjuvant setting after hysterectomy for treatment of women with FIGO stage I-II EC. VB alone appears to be replacing pelvic EBRT and VB+EBRT therapy in the management of stage I-II EC.« less

  11. Impact of a commercially available model-based dose calculation algorithm on treatment planning of high-dose-rate brachytherapy in patients with cervical cancer.

    PubMed

    Abe, Kota; Kadoya, Noriyuki; Sato, Shinya; Hashimoto, Shimpei; Nakajima, Yujiro; Miyasaka, Yuya; Ito, Kengo; Umezawa, Rei; Yamamoto, Takaya; Takahashi, Noriyoshi; Takeda, Ken; Jingu, Keiichi

    2018-03-01

    We evaluated the impact of model-based dose calculation algorithms (MBDCAs) on high-dose-rate brachytherapy (HDR-BT) treatment planning for patients with cervical cancer. Seven patients with cervical cancer treated using HDR-BT were studied. Tandem and ovoid applicators were used in four patients, a vaginal cylinder in one, and interstitial needles in the remaining two patients. MBDCAs were applied to the Advanced Collapsed cone Engine (ACE; Elekta, Stockholm, Sweden). All plans, which were originally calculated using TG-43, were re-calculated using both ACE and Monte Carlo (MC) simulations. Air was used as the rectal material. The mean difference in the rectum D2cm3 between ACErec-air and MCrec-air was 8.60 ± 4.64%, whereas that in the bladder D2cm3 was -2.80 ± 1.21%. Conversely, in the small group analysis (n = 4) using water instead of air as the rectal material, the mean difference in the rectum D2cm3 between TG-43 and ACErec-air was 11.87 ± 2.65%, whereas that between TG-43 and ACErec-water was 0.81 ± 2.04%, indicating that the use of water as the rectal material reduced the difference in D2cm3 between TG-43 and ACE. Our results suggested that the differences in the dose-volume histogram (DVH) parameters of TG-43 and ACE were large for the rectum when considerable air (gas) volume was present in it, and that this difference was reduced when the air (gas) volume was reduced. Also, ACE exhibited better dose calculation accuracy than that of TG-43 in this situation. Thus, ACE may be able to calculate the dose more accurately than TG-43 for HDR-BT in treating cervical cancers, particularly for patients with considerable air (gas) volume in the rectum.

  12. Impact of a commercially available model-based dose calculation algorithm on treatment planning of high-dose-rate brachytherapy in patients with cervical cancer

    PubMed Central

    Abe, Kota; Kadoya, Noriyuki; Sato, Shinya; Hashimoto, Shimpei; Nakajima, Yujiro; Miyasaka, Yuya; Ito, Kengo; Umezawa, Rei; Yamamoto, Takaya; Takahashi, Noriyoshi; Takeda, Ken; Jingu, Keiichi

    2018-01-01

    Abstract We evaluated the impact of model-based dose calculation algorithms (MBDCAs) on high-dose-rate brachytherapy (HDR-BT) treatment planning for patients with cervical cancer. Seven patients with cervical cancer treated using HDR-BT were studied. Tandem and ovoid applicators were used in four patients, a vaginal cylinder in one, and interstitial needles in the remaining two patients. MBDCAs were applied to the Advanced Collapsed cone Engine (ACE; Elekta, Stockholm, Sweden). All plans, which were originally calculated using TG-43, were re-calculated using both ACE and Monte Carlo (MC) simulations. Air was used as the rectal material. The mean difference in the rectum D2cm3 between ACErec-air and MCrec-air was 8.60 ± 4.64%, whereas that in the bladder D2cm3 was −2.80 ± 1.21%. Conversely, in the small group analysis (n = 4) using water instead of air as the rectal material, the mean difference in the rectum D2cm3 between TG-43 and ACErec-air was 11.87 ± 2.65%, whereas that between TG-43 and ACErec-water was 0.81 ± 2.04%, indicating that the use of water as the rectal material reduced the difference in D2cm3 between TG-43 and ACE. Our results suggested that the differences in the dose–volume histogram (DVH) parameters of TG-43 and ACE were large for the rectum when considerable air (gas) volume was present in it, and that this difference was reduced when the air (gas) volume was reduced. Also, ACE exhibited better dose calculation accuracy than that of TG-43 in this situation. Thus, ACE may be able to calculate the dose more accurately than TG-43 for HDR-BT in treating cervical cancers, particularly for patients with considerable air (gas) volume in the rectum. PMID:29378024

  13. Outcomes and toxicities in patients with intermediate-risk prostate cancer treated with brachytherapy alone or brachytherapy and supplemental external beam radiation therapy.

    PubMed

    Schlussel Markovic, Emily; Buckstein, Michael; Stone, Nelson N; Stock, Richard G

    2018-05-01

    To evaluate the cancer control outcomes and long-term treatment-related morbidity of brachytherapy as well as combination brachytherapy and external beam radiation therapy (EBRT) in patients with intermediate-risk prostate cancer. A retrospective review was conducted in a prospectively collected database of patients with intermediate-risk prostate cancer who were treated either with brachytherapy or brachytherapy and EBRT, with or without androgen deprivation therapy (ADT), in the period 1990-2014. Urinary and erectile dysfunction symptoms were measured using the International Prostate Symptom Score (IPSS), the Mount Sinai erectile function scale and the Sexual Health Inventory for Men (SHIM). Cancer control endpoints included biochemical failure and development of distant metastases. All statistical analyses were carried out using the Statistical Package for Social Science (SPSS). Survival curves were calculated using Kaplan-Meier actuarial methods and compared using log-rank tests. Cox regression multivariate analyses were used to test the effect of multiple variables on treatment outcomes. A total of 902 patients were identified, with a median follow-up of 91 months. Of these, 390 received brachytherapy and 512 received combination therapy with EBRT. In patients with one intermediate-risk factor, the addition of EBRT did not significantly affect freedom from biochemical failure or distant metastases. Among patients with two or three intermediate-risk factors, added EBRT did not improve freedom from biochemical failure. Significant differences in late toxicity between patients treated with brachytherapy vs combination brachytherapy and EBRT were identified including urge incontinence (P < 0.001), haematuria (P < 0.001), dysuria (P < 0.001), and change in quality-of-life IPSS (P = 0.002). These symptoms were reported by patients at any point during treatment follow-up. Analysis of patients who were potent before treatment using actuarial methods showed that

  14. 4 x 8 inch concrete cylinders versus 6 x 12 cylinders.

    DOT National Transportation Integrated Search

    1984-01-01

    Laboratory and field investigations were conducted to compare the compressive strengths obtained for 4 x 8 in. (100 x 200 mm) cylinders with those for standard 6 x 12 in. (150 x 300 mm) cylinders, both made with aggregate having a nominal maximum siz...

  15. Trends in the Utilization of Brachytherapy in Cervical Cancer in the United States

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Han, Kathy, E-mail: Kathy.Han@rmp.uhn.on.ca; Milosevic, Michael; Fyles, Anthony

    2013-09-01

    Purpose: To determine the trends in brachytherapy use in cervical cancer in the United States and to identify factors and survival benefits associated with brachytherapy treatment. Methods and Materials: Using the Surveillance, Epidemiology, and End Results (SEER) database, we identified 7359 patients with stages IB2-IVA cervical cancer treated with external beam radiation therapy (EBRT) between 1988 and 2009. Propensity score matching was used to adjust for differences between patients who received brachytherapy and those who did not from 2000 onward (after the National Cancer Institute alert recommending concurrent chemotherapy). Results: Sixty-three percent of the 7359 women received brachytherapy in combinationmore » with EBRT, and 37% received EBRT alone. The brachytherapy utilization rate has decreased from 83% in 1988 to 58% in 2009 (P<.001), with a sharp decline of 23% in 2003 to 43%. Factors associated with higher odds of brachytherapy use include younger age, married (vs single) patients, earlier years of diagnosis, earlier stage and certain SEER regions. In the propensity score-matched cohort, brachytherapy treatment was associated with higher 4-year cause-specific survival (CSS; 64.3% vs 51.5%, P<.001) and overall survival (OS; 58.2% vs 46.2%, P<.001). Brachytherapy treatment was independently associated with better CSS (hazard ratio [HR], 0.64; 95% confidence interval [CI], 0.57-0.71), and OS (HR 0.66; 95% CI, 0.60 to 0.74). Conclusions: This population-based analysis reveals a concerning decline in brachytherapy utilization and significant geographic disparities in the delivery of brachytherapy in the United States. Brachytherapy use is independently associated with significantly higher CSS and OS and should be implemented in all feasible cases.« less

  16. Vaginitis test - wet mount

    MedlinePlus

    ... prep - vaginitis; Vaginosis - wet mount; Trichomoniasis - wet mount; Vaginal candida - wet mount ... provider gently inserts an instrument (speculum) into the vagina to hold it open and view inside. A ...

  17. Fractionated stereotactic radiotherapy boost for gynecologic tumors: An alternative to brachytherapy?

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Molla, Meritxell; Escude, Lluis D.; Nouet, Philippe

    2005-05-01

    Purpose: A brachytherapy (BT) boost to the vaginal vault is considered standard treatment for many endometrial or cervical cancers. We aimed to challenge this treatment standard by using stereotactic radiotherapy (SRT) with a linac-based micromultileaf collimator technique. Methods and Materials: Since January 2002, 16 patients with either endometrial (9) or cervical (7) cancer have been treated with a final boost to the areas at higher risk for relapse. In 14 patients, the target volume included the vaginal vault, the upper vagina, the parametria, or (if not operated) the uterus (clinical target volume [CTV]). In 2 patients with local relapse, themore » CTV was the tumor in the vaginal stump. Margins of 6-10 mm were added to the CTV to define the planning target volume (PTV). Hypofractionated dynamic-arc or intensity-modulated radiotherapy techniques were used. Postoperative treatment was delivered in 12 patients (2 x 7 Gy to the PTV with a 4-7-day interval between fractions). In the 4 nonoperated patients, a dose of 4 Gy/fraction in 5 fractions with 2 to 3 days' interval was delivered. Patients were immobilized in a customized vacuum body cast and optimally repositioned with an infrared-guided system developed for extracranial SRT. To further optimize daily repositioning and target immobilization, an inflated rectal balloon was used during each treatment fraction. In 10 patients, CT resimulation was performed before the last boost fraction to assess for repositioning reproducibility via CT-to-CT registration and to estimate PTV safety margins around the CTV. Finally, a comparative treatment planning study between BT and SRT was performed in 2 patients with an operated endometrial Stage I cancer. Results: No patient developed severe acute urinary or low-intestinal toxicity. No patient developed urinary late effects (>6 months). One patient with a vaginal relapse previously irradiated to the pelvic region presented with Grade 3 rectal bleeding 18 months after

  18. Vaginitis.

    PubMed

    Friedrich, E G

    1985-06-01

    Vaginitis is one of the most common complaints of women in the United States today. About 90% of patients with this problem suffer from infection of the vagina caused by Candida, Gardnerella, or Trichomonas. The diagnosis and effective treatment of these common infections depend on accurate identification of the entity, effective specific therapy, and restoration of the normal ecosystem of the vagina. At the same time women should be made aware that not all discharge means infection and that any attempts at self-treatment may only worsen their condition. Proper hygiene habits, dietary control, and management of stress are all helpful factors in the control of recurrent vaginal infections.

  19. Protective activity of geranium oil and its component, geraniol, in combination with vaginal washing against vaginal candidiasis in mice.

    PubMed

    Maruyama, Naho; Takizawa, Toshio; Ishibashi, Hiroko; Hisajima, Tatsuya; Inouye, Shigeharu; Yamaguchi, Hideyo; Abe, Shigeru

    2008-08-01

    In order to evaluate an effective administration method of essential oils for vaginal candidiasis, efficacy of vaginal application of essential oils against murine experimental candidiasis was investigated. The effect on vaginal inflammation and Candida growth form was also studied. Vaginal candidiasis was established by intravaginal infection of C. albicans to estradiol-treated mice. These mice intravaginally received essential oils such as geranium and tea tree singly or in combination with vaginal washing. Vaginal administration of clotrimazole significantly decreased the number of viable C. albicans cells in the vaginal cavity by itself. In contrast, these essential oils did not lower the cell number. When application of geranium oil or geraniol was combined with vaginal washing, the cell number was decreased significantly. The myeloperoxidase activity assay exhibited the possibility that essential oils worked not only to reduce the viable cell number of C. albicans, but also to improve vaginal inflammation. The smear of vaginal washing suspension suggested that more yeast-form cells appeared in vaginal smears of these oil-treated mice than in control mice. In vitro study showed that a very low concentration (25 microg/ml) of geranium oil and geraniol inhibited mycelial growth, but not yeast growth. Based on these findings, it is estimated that vaginal application of geranium oil or its main component, geraniol, suppressed Candida cell growth in the vagina and its local inflammation when combined with vaginal washing.

  20. Beneficial effects of a Coriolus versicolor-based vaginal gel on cervical epithelization, vaginal microbiota and vaginal health: a pilot study in asymptomatic women.

    PubMed

    Palacios, Santiago; Losa, Fernando; Dexeus, Damián; Cortés, Javier

    2017-03-16

    To assess the effect of a 12-day treatment using a vaginal gel based on niosomes containing hyaluronic acid, ß-glucan, alpha-glucan oligosaccharide, Coriolus versicolor, Asian centella, Azadirachta indica and Aloe vera on vaginal microbiota, cervical epithelization and vaginal health. Open-label, prospective pilot study conducted in asymptomatic women in daily practice. Cervical epithelization was evaluated by colposcopy using an ectopy epithelization score (from 5: no ectopy to 1: severe ectopy and bleeding), vaginal microbiota using the VaginaStatus-Diagnostic test (Instiüt für Mikroökologie, Herborn, Germany) and further rated by the investigator using a 5-point Liker scale (from 5: normal to 1: very severe deterioration in which all evaluated species were altered), and vaginal health using the Vaginal Health Index. In 21 women, a positive effect to improve epithelization of the cervical mucosa, with a mean score of 4.42 at the final visit as compared to 3.09 at baseline (P < 0.0001) (43% improvement). In 10 women, there was a trend of improving of vaginal microbiota status, with a mean score of 4.0 at the final visit vs. 3.3 at baseline (P = NS) (21.2% improvement). In 11 women, the Vaginal Health Index increased from 19.0 at baseline to 22.3 at the final visit (P = 0.007). The concentration of Lactobacillus spp. increased 54.5% of women and pH decreased from 4.32 to 4.09. These encouraging preliminary results provide the basis for designing a randomized controlled study, and for potential use in human papilloma virus infection. ISRCTN77955077 . Registration date: February 15, 2017. Retrospectively registered.

  1. Vaginal metastasis presenting as postmenopausal bleeding.

    PubMed

    Ng, Qiu Ju; Namuduri, Rama Padma; Yam, Kwai Lam; Lim-Tan, Soo Kim

    2015-08-01

    Vaginal cancer is rare worldwide and represents 2% of all gynaecological cancers in Singapore. Primary vaginal malignancies are rare and vaginal metastases constitute the majority of vaginal malignancies. Most of these metastases arise from the cervix, endometrium or ovary, although they can also metastasise from distant sites such as the colon, breast and pancreas. We report a rare case of vaginal metastasis in a patient with previous gastric and rectal adenocarcinomas. An 89-year-old woman with a history of gastric and rectal malignancy presented with postmenopausal bleeding. A 2-cm vaginal tumour at the introitus was discovered upon examination. This case demonstrates the importance of performing a gynaecological examination during follow-up for patients with a history of malignancy. The prognosis for vaginal metastasis is poor, as it is often associated with disseminated disease. Depending on the extent of the lesions, radiotherapy or surgery can be considered.

  2. Administration of oral and vaginal prebiotic lactoferrin for a woman with a refractory vaginitis recurring preterm delivery: appearance of lactobacillus in vaginal flora followed by term delivery.

    PubMed

    Otsuki, Katsufumi; Tokunaka, Mayumi; Oba, Tomohiro; Nakamura, Masamitsu; Shirato, Nahoko; Okai, Takashi

    2014-02-01

    Lactoferrin (LF) is one of the prebiotics present in the human body. A 38-year-old multiparous woman with poor obstetrical histories, three consecutive preterm premature rupture of membrane at the 19th, 23rd and 25th week of pregnancy, was referred to our hospital. She was diagnosed as having refractory vaginitis. Although estriol vaginal tablets were used for 4 months, the vaginitis was not cured. We administrated vaginal tablets and oral agents of prebiotic LF, resulting in a Lactobacillus predominant vaginal flora. When she was pregnant, she continued to use the LF, and the Lactobacillus in the vaginal flora was continuously observed during pregnancy. An elective cesarean section was performed at the 38th week of pregnancy. When the administration of LF was discontinued after the delivery, Lactobacillus in the vaginal flora was disappeared. © 2013 The Authors. Journal of Obstetrics and Gynaecology Research © 2013 Japan Society of Obstetrics and Gynecology.

  3. American Brachytherapy Society consensus report for accelerated partial breast irradiation using interstitial multicatheter brachytherapy.

    PubMed

    Hepel, Jaroslaw T; Arthur, Douglas; Shaitelman, Simona; Polgár, Csaba; Todor, Dorin; Zoberi, Imran; Kamrava, Mitchell; Major, Tibor; Yashar, Catheryn; Wazer, David E

    To develop a consensus report for the quality practice of accelerated partial breast irradiation (APBI) using interstitial multicatheter brachytherapy (IMB). The American Brachytherapy Society Board appointed an expert panel with clinical and research experience with breast brachytherapy to provide guidance for the current practice of IMB. This report is based on a comprehensive literature review with emphasis on randomized data and expertise of the panel. Randomized trials have demonstrated equivalent efficacy of APBI using IMB compared with whole breast irradiation for select patients with early-stage breast cancer. Several techniques for placement of interstitial catheters are described, and importance of three-dimensional planning with appropriate optimization is reviewed. Optimal target definition is outlined. Commonly used dosing schemas include 50 Gy delivered in pulses of 0.6-0.8 Gy/h using pulsed-dose-rate technique and 34 Gy in 10 fractions, 32 Gy in eight fractions, or 30 Gy in seven fractions using high-dose-rate technique. Potential toxicities and strategies for toxicity avoidance are described in detail. Dosimetric constraints include limiting whole breast volume that receives ≥50% of prescription dose to <60%, skin dose to ≤100% of prescription dose (≤60-70% preferred), chest wall dose to ≤125% of prescription dose, Dose Homogeneity Index to >0.75 (>0.85 preferred), V 150  < 45 cc, and V 200  < 14 cc. Using an optimal implant technique coupled with optimal planning and appropriate dose constraints, a low rate of toxicity and a good-to-excellent cosmetic outcome of ≥90% is expected. IMB is an effective technique to deliver APBI for appropriately selected women with early-stage breast cancer. This consensus report has been created to assist clinicians in the appropriate practice of APBI using IMB. Copyright © 2017 American Brachytherapy Society. Published by Elsevier Inc. All rights reserved.

  4. Radioactive implant migration in patients treated for localized prostate cancer with interstitial brachytherapy.

    PubMed

    Older, R A; Synder, B; Krupski, T L; Glembocki, D J; Gillenwater, J Y

    2001-05-01

    In several of the initial patients undergoing brachytherapy at our institution radioactive implants were visible in the thorax on chest radiography. The clinical ramifications of this unanticipated finding were unclear. Thus, we investigated the incidence of brachytherapy seed migration to the chest and whether these seeds were associated with any clinical significance. We retrospectively reviewed the records of all patients who underwent ultrasound or computerized tomography guided brachytherapy of 103palladium seeds from March 1997 to March 1999. This list of patients on brachytherapy was then matched against the radiology computer system to determine those who had undergone chest X-ray after brachytherapy. When the radiology report was unclear regarding brachytherapy seeds, chest x-rays were reviewed by one of us (R. O.) to determine the presence and position of the seeds. Post-brachytherapy chest x-rays were available in 110 of the 183 patients. In 78 cases no brachytherapy seeds were identified. Radioactive implants were identified on chest radiography in 32 patients (29%), including 1 to 5 seeds in 20, 8, 1, 2 and 1, respectively. No patients complained of any change in pulmonary symptoms after brachytherapy. Radioactive implants migrated after brachytherapy for localized prostate cancer in 29% of the patients who underwent post-procedure radiography. There did not appear to be a pattern to the seed distribution. However, while the incidence was not negligible, no patient appeared to have any acute pulmonary symptoms. Therefore, while the migration of radioactive implants to the chest is a real phenomenon, it appears to have no adverse clinical consequences in the early post-procedure period.

  5. Radioactive seed migration following parotid gland interstitial brachytherapy.

    PubMed

    Fan, Yi; Huang, Ming-Wei; Zhao, Yi-Jiao; Gao, Hong; Zhang, Jian-Guo

    To evaluate the incidence and associated factors of pulmonary seed migration after parotid brachytherapy using a novel migrated seed detection technique. Patients diagnosed with parotid cancer who underwent permanent parotid brachytherapy from January 2006 to December 2011 were reviewed retrospectively. Head and neck CT scans and chest X-rays were evaluated during routine follow-up. Mimics software and Geomagic Studio software were used for seed reconstruction and migrated seed detection from the original implanted region, respectively. Postimplant dosimetry analysis was performed after seeds migration if the seeds were still in their emitting count. Adverse clinical sequelae from seed embolization to the lung were documented. The radioactive seed implants were identified on chest X-rays in 6 patients. The incidence rate of seed migration in 321 parotid brachytherapy patients was 1.87% (6/321) and that of individual seed migration was 0.04% (6/15218 seeds). All migrated seeds were originally from the retromandibular region. No adverse dosimetric consequences were found in the target region. Pulmonary symptoms were not reported by any patient in this study. In our patient set, migration of radioactive seeds with an initial radioactivity of 0.6-0.7 mCi to the chest following parotid brachytherapy was rare. Late migration of a single seed from the central target region did not affect the dosimetry significantly, and patients did not have severe short-term complications. This study proposed a novel technique to localize the anatomical origin of the migrated seeds during brachytherapy. Our evidence suggested that placement of seeds adjacent to blood vessels was associated with an increased likelihood of seed migration to the lungs. Copyright © 2017 American Brachytherapy Society. Published by Elsevier Inc. All rights reserved.

  6. Urethral toxicity after LDR brachytherapy: experience in Japan.

    PubMed

    Tanaka, Nobumichi; Asakawa, Isao; Hasegawa, Masatoshi; Fujimoto, Kiyohide

    2015-01-01

    Urinary toxicity is common after low-dose-rate (LDR) brachytherapy, and the resolution of urinary toxicity is a concern. In particular, urinary frequency is the most common adverse event among the urinary toxicities. We have previously reported that approximately 70% of patients experience urinary frequency during the first 6 months after seed implantation. Most urinary adverse events were classified as Grade 1, and Grade 2 or higher adverse events were rare. The incidence of urinary retention was approximately 2-4%. A high International Prostate Symptom Score before seed implantation was an independent predictor of acute urinary toxicity of Grade 2 or higher. Several previous reports from the United States also supported this trend. In Japan, LDR brachytherapy was legally approved in 2003. A nationwide prospective cohort study entitled Japanese Prostate Cancer Outcome Study of Permanent Iodine-125 Seed Implantation was initiated in July 2005. It is an important issue to limit urinary toxicities in patients who undergo LDR brachytherapy. Copyright © 2015 American Brachytherapy Society. Published by Elsevier Inc. All rights reserved.

  7. [Developments in brachytherapy].

    PubMed

    Ikeda, H

    1995-09-01

    Brachytherapy is one of the ideal methods of radiotherapy because of the concentration of a high dose on the target. Recent developments, including induction of afterloading method, utilization of small-sized high-activity sources such as Iridium-192, and induction of high technology and computerization, have made for shortening of irradiation time and source handling, which has led to easier management of the patient during treatment. Dose distribution at high dose rate (HDR) is at least as good as that of low dose rate (LDR), and selection of fractionation and treatment time assures even greater biological effects on hypoxic tumor cells than LDR. Experience with HDR brachytherapy in uterine cervix cancer using Cobalt-60 during the past 20 years in this country has gradually been evaluated in U.S. and Europe. The indications for HDR treatment have extended to esophagus, bronchus, bile duct, brain, intraoperative placement of source guide, and perineal region using templates, as well as the conventional use for uterus, tongue and so on.

  8. Dynamic Friction Performance of a Pneumatic Cylinder with Al2O3 Film on Cylinder Surface.

    PubMed

    Chang, Ho; Lan, Chou-Wei; Wang, Hao-Xian

    2015-11-01

    A friction force system is proposed for accurately measuring friction force and motion properties produced by reciprocating motion of piston in a pneumatic cylinder. In this study, the proposed system is used to measure the effects of lubricating greases of different viscosities on the friction properties of pneumatic cylinder, and improvement of stick-slip motion for the cylinder bore by anodizing processes. A servo motor-driven ball screw is used to drive the pneumatic cylinder to be tested and to measure the change in friction force of the pneumatic cylinder. Experimental results show, that under similar test conditions, the lubricating grease with viscosity VG100 is best suited for measuring reciprocating motion of the piston of pneumatic cylinder. The wear experiment showed that, in the Al2O3 film obtained at a preset voltage 40 V in the anodic process, the friction coefficient and hardness decreased by 55% and increased by 274% respectively, thus achieving a good tribology and wear resistance. Additionally, the amplitude variation in the friction force of the pneumatic cylinder wall that received the anodizing treatment was substantially reduced. Additionally, the stick-slip motion of the pneumatic cylinder during low-speed motion was substantially improved.

  9. Vaginal sponge and spermicides

    MedlinePlus

    Birth control - over the counter; Contraceptives - over the counter; Family planning - vaginal sponge; Contraception - vaginal sponge ... preventing pregnancy as some other forms of birth control. However, using a spermicide or sponge is much ...

  10. Douching for perceived vaginal odor with no infectious cause of vaginitis: a randomized controlled trial.

    PubMed

    Hassan, Sarmina; Chatwani, Ashwin; Brovender, Herman; Zane, Richard; Valaoras, Thomas; Sobel, Jack D

    2011-04-01

    To demonstrate the effectiveness of medical-grade stainless steel Water Works Douching Device for treating abnormal vaginal odor in comparison with a commercially available over-the-counter plastic douching device. In a multicenter study, 140 women with perceived vaginal odor with no vaginal infection were randomized to either Water Works or control group in a 1:1 ratio and were douched daily for 4 weeks. A visual analog scale (VAS) was used to assess the intensity of vaginal odor. Primary outcome included subject assessment of odor improvement and Nugent Gram stain score of vaginal secretions. Secondary outcome compared the efficacy and safety of Water Works with control douching device. Each patient underwent baseline, week 2, and week 4 visits. The final analytic sample consisted of 96 women. Success score at 4 weeks was 78% for the Water Works group and 38.5% for the control group. Mean VAS was significantly reduced, and Nugent and Lactobacillus scores were maintained in both groups. In the Water Works group, VAS was reduced from 7.3 ± 0.3 to 1.8 ± 0.6 (p < .001) after 4 weeks. In the control group, baseline versus 4 weeks VAS was 7.2 ± 0.3 and 3.4 ± 0.8 (p < .003). Women reported significant reduction of vaginal odor after douching with water for 4 weeks without any alteration of vaginal flora. The Water Works Douching Device was superior to over- the-counter device in reducing vaginal odor.

  11. Innovative non-surgical management of pelvic and anterior vaginal wall abscess following vaginal surgery.

    PubMed

    Singh, Nisha; Negi, Neha; Kumar, Namrata

    2016-08-29

    Surgical site infections remain a common cause of morbidity following gynaecological surgery. The widespread implementation of antibiotic prophylaxis prior to surgery, as well as cognizance of modifiable risk factors for postoperative infection, has led to a significant reduction in postoperative infection rates. However, in low resource settings where sepsis and infections are common, surgical site infections following vaginal hysterectomy are sometimes encountered. It is a challenge to treat these infections with minimal intervention avoiding repeat surgery. We report here a unique situation following vaginal hysterectomy and then laparotomy; where a pelvic abscess communicated with the vesicovaginal space and drained through an opening into the anterior vaginal wall. An innovative technique was used to drain this anterior vaginal wall abscess connecting to pelvic cavity using a 40 cm long disposable urinary catheter (made of polyvinyl chloride), which was inserted into the vaginal opening under ultrasound guidance. 2016 BMJ Publishing Group Ltd.

  12. Three or four fractions of 4-5 Gy per week in postoperative high-dose-rate brachytherapy for endometrial carcinoma.

    PubMed

    Rovirosa, Angeles; Ascaso, Carlos; Sánchez-Reyes, Alberto; Herreros, Antonio; Abellana, Rosa; Pahisa, Jaume; Lejarcegui, Jose Antonio; Biete, Albert

    2011-10-01

    To evaluate the results of high-dose-rate brachytherapy (HDRBT) using a schedule of three or four fractions per week, when possible, in 89 patients on local control and toxicity in postoperative treatment of endometrial carcinoma. The effect of the overall HDRBT treatment time (OTT) on toxicity was also evaluated. Fédération Internationale de Gynécologie Obstétrique Stage: 24 IB, 45 IC, 4 IIA, 6 IIB, 4 IIIA, 2 IIIB, and 4 IIIC. Radiotherapy: Group 1-67 of 89 patients received external beam irradiation (EBI; 44-50 Gy) plus HDRBT (3 fractions of 4-6 Gy); Group 2-22 of 89 patients received HDRBT alone (6 fractions of 4-5 Gy). OTT: Group 1-HDRBT was completed in a median of 5 days in 32 patients and in >5 days in 35; Group 2-HDRBT was completed in <15 days in 11 patients and in ≥16 days in 11. Toxicity was evaluated using Radiation Therapy Oncology Group scores and the bioequivalent dose (BED) study was performed in vaginal mucosa surface. Statistics included Student's t test, chi-square test, and receiving operator curves. With a mean follow-up of 31 months (range, 6-70), 1 of 89 patients had vaginal relapse. Early toxicity appeared in 8 of 89 (9%) patients and was resolved. Late toxicity appeared in 13/89 (14%): vaginal nine Grade 1, three Grade 2, one Grade 4; bladder two Grade 2; rectal three Grade 1, one Grade 2. No differences were found in relation to OTT in Groups 1 and 2. Mean BED was 88.48 Gy in Group 1 and 165.28 Gy in Group 2. Cases with Grade 2 late vaginal toxicity received >75 Gy after EBI and >165 Gy in Group 2. Three fractions of 4-5 Gy in 3-5 days after EBI or 6 fractions in <15 days in patients receiving HDRBT alone was a safe treatment in relation to toxicity and local control. Vaginal surface BED less than 75 Gy after EBI and less than 160 Gy in HDRBT alone may be safe to avoid G2 toxicity. Copyright © 2011 Elsevier Inc. All rights reserved.

  13. Three or Four Fractions of 4-5 Gy per Week in Postoperative High-Dose-Rate Brachytherapy for Endometrial Carcinoma

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Rovirosa, Angeles, E-mail: rovirosa@clinic.ub.es; Ascaso, Carlos; Sanchez-Reyes, Alberto

    2011-10-01

    Purpose: To evaluate the results of high-dose-rate brachytherapy (HDRBT) using a schedule of three or four fractions per week, when possible, in 89 patients on local control and toxicity in postoperative treatment of endometrial carcinoma. The effect of the overall HDRBT treatment time (OTT) on toxicity was also evaluated. Patients and Methods: Federation Internationale de Gynecologie Obstetrique Stage: 24 IB, 45 IC, 4 IIA, 6 IIB, 4 IIIA, 2 IIIB, and 4 IIIC. Radiotherapy: Group 1-67 of 89 patients received external beam irradiation (EBI; 44-50 Gy) plus HDRBT (3 fractions of 4-6 Gy); Group 2-22 of 89 patients received HDRBTmore » alone (6 fractions of 4-5 Gy). OTT: Group 1-HDRBT was completed in a median of 5 days in 32 patients and in >5 days in 35; Group 2-HDRBT was completed in <15 days in 11 patients and in {>=}16 days in 11. Toxicity was evaluated using Radiation Therapy Oncology Group scores and the bioequivalent dose (BED) study was performed in vaginal mucosa surface. Statistics included Student's t test, chi-square test, and receiving operator curves. Results: With a mean follow-up of 31 months (range, 6-70), 1 of 89 patients had vaginal relapse. Early toxicity appeared in 8 of 89 (9%) patients and was resolved. Late toxicity appeared in 13/89 (14%): vaginal nine Grade 1, three Grade 2, one Grade 4; bladder two Grade 2; rectal three Grade 1, one Grade 2. No differences were found in relation to OTT in Groups 1 and 2. Mean BED was 88.48 Gy in Group 1 and 165.28 Gy in Group 2. Cases with Grade 2 late vaginal toxicity received >75 Gy after EBI and >165 Gy in Group 2. Conclusions: Three fractions of 4-5 Gy in 3-5 days after EBI or 6 fractions in <15 days in patients receiving HDRBT alone was a safe treatment in relation to toxicity and local control. Vaginal surface BED less than 75 Gy after EBI and less than 160 Gy in HDRBT alone may be safe to avoid G2 toxicity.« less

  14. The stimulation of the vaginal immune system with short-term administration of a vaginal gel containing fraction of Propionibacterium acnes, hyaluronic acid and polycarbophil is efficacious in vaginal infections dependent on disorders in the vaginal ecosystem.

    PubMed

    Melis, Gian Benedetto; Piras, Bruno; Marotto, Maria Francesca; Neri, Manuela; Corda, Valentina; Vallerino, Valerio; Saba, Alessandra; Lello, Stefano; Pilloni, Monica; Zedda, Pierina; Paoletti, Anna Maria; Mais, Valerio

    2018-04-12

    The vaginal immune system (VIS) is the first defense against antigens recognized as foreign. Substances capable of locally activating the VIS could be a valid strategy to treat vulvo-vaginal infections (VVI), caused by changes in the vaginal ecosystem, such as bacterial vaginosis (BV), vulvo-vaginal candidiasis (CA), and mixed vaginitis (MV). Bacterial lysates, obtained by crushing bacterial cultures, exert immuno-modulatory activities. The parietal fraction from Propionibacterium acnes is a patent of Depofarma (MoglianoVeneto, Italy). The preparation that associates such fraction to hyaluronic acid and polycarbophil is a registered trademark, commercially available in Italy as vaginal gel, Immunovag ® . The study aimed to evaluate whether a 5-day-treatment with Immunovag ® improves the symptoms and signs of VVI, in 60 women with Gardnerella vaginalis (GV), 154 with CA, 95 with MV, diagnosed with vulvar vaginal swab (VVS), and in 283 with BV, diagnosed with the Amsel criteria. At the end of the treatment (visit 2), the symptoms and signs of VVI disappeared in a significant number of subjects (χ 2 p < .02 vs pre-treatment) in all VVI groups, and their intensity was significantly (p < .0002) reduced in the subjects in which they were still present. Immunovag ® represents a valid treatment of VVI induced by changes in the vaginal ecosystem.

  15. A survey of current clinical practice in permanent and temporary prostate brachytherapy: 2010 update.

    PubMed

    Buyyounouski, Mark K; Davis, Brian J; Prestidge, Bradley R; Shanahan, Thomas G; Stock, Richard G; Grimm, Peter D; Demanes, D Jeffrey; Zaider, Marco; Horwitz, Eric M

    2012-01-01

    To help establish patterns of care and standards of care of interstitial permanent low-dose-rate (LDR) and temporary high-dose-rate brachytherapy for prostate cancer and to compare the results with a similar 1998 American Brachytherapy Society (ABS) survey. A comprehensive questionnaire intended to survey specific details of current clinical brachytherapy practice was provided to the participants of the seventh ABS Prostate Brachytherapy School. Responses were tabulated and descriptive statistics are reported. Sixty-five brachytherapy practitioners responded to the survey. Eighty-nine percent (89%) of respondents performed LDR and 49% perform high-dose-rate brachytherapy. The median number of years of experience for LDR brachytherapists increased from 5 to 10 years over the course of the 12 years since the preceding survey. Compared with the first ABS, a smaller proportion of respondents received formal brachytherapy residency training (43% vs. 56%) or formal "hands-on" brachytherapy training (15% vs. 63%). There has been a marked decline in the utilization of the Mick applicator (Mick Radio-Nuclear Instruments, Inc., Mount Vernon, NY, USA) (60% vs. 28%) and an increase in the use of stranded seeds (40% vs. 11%). Compliance with postimplant dosimetry was higher in the 2010 survey. This survey does suggest an evolution in the practice of LDR brachytherapy since 1998 and aids in identifying aspects that require further progress or investigation. ABS guidelines and other practice recommendations appear to impact the practice of brachytherapy. Copyright © 2012 American Brachytherapy Society. Published by Elsevier Inc. All rights reserved.

  16. Reducing cylinder drag by adding a plate

    NASA Astrophysics Data System (ADS)

    Frolov, Vladimir A.; Kozlova, Anna S.

    2017-10-01

    Reducing the drag of bodies is a central problem of modern aerohydrodynamics. The paper presents theoretical and experimental studies of a new method for reducing the drag of a circular cylinder. To reduce the drag we propose to install a flat plate along the flow in front of the cylinder. The theoretical investigation of the drag was carried out using FlowSimulation software. An experimental study of the body drag was performed in an open wind tunnel. The drag coefficient results of the cylinder depended on the different locations of the flat plate relative to the cylinder. The following geometric characteristics of the cylinder/plate are studied: the width of the gap between the cylinder and the plate and the meridional angle of the plate with respect to the cylinder. On the basis of Numerical and Physical Modeling, the values of the drag coefficient for the cylinder/plate are presented. The results included establishment the locations of the cylinder/plate which give the value of the drag coefficient for the combination of the two bodies. That total drag coefficient of the cylinder/plate can be less than the cylinder alone.

  17. Dosimetric characteristics of a new unit for electronic skin brachytherapy

    PubMed Central

    Garcia-Martinez, Teresa; Chan, Jan-Pieter; Perez-Calatayud, Jose

    2014-01-01

    Purpose Brachytherapy with radioactive high dose rate (HDR) 192Ir source is applied to small skin cancer lesions, using surface applicators, i.e. Leipzig or Valencia type. New developments in the field of radiotherapy for skin cancer include electronic brachytherapy. This technique involves the placement of an HDR X-ray source close to the skin, therefore combining the benefits of brachytherapy with the reduced shielding requirements and targeted energy of low energy X-rays. Recently, the Esteya® Electronic Brachytherapy System (Esteya EBS, Elekta AB-Nucletron, Stockholm, Sweden) has been developed specifically for HDR brachytherapy treatment of surface lesions. The system provides radionuclide free HDR brachytherapy by means of a small 69.5 kV X-ray source. The purpose of this study is to obtain the dosimetric characterization required for clinical implementation, providing the detailed methodology to perform the commissioning. Material and methods Flatness, symmetry and penumbra, percentage of depth dose (PDD), kV stability, HVL, output, spectrum, linearity, and leakage have been evaluated for a set of applicators (from 10 mm to 30 mm in diameter). Results Flatness and symmetry resulted better than 5% with around 1 mm of penumbra. The depth dose gradient is about 7%/mm. A kV value of 68.4 ± 1.0 kV (k = 1) was obtained, in good agreement with manufacturer data (69.5 kV). HVL was 1.85 mm Al. Dose rate for a typical 6 Gy to 7 Gy prescription resulted about 3.3 Gy/min and the leakage value was < 100 µGy/min. Conclusions The new Esteya® Electronic Brachytherapy System presents excellent flatness and penumbra as with the Valencia applicator case, combined with an improved PDD, allowing treatment of lesions of up to a depth of 5 mm in combination with reduced treatment duration. The Esteya unit allows HDR brachytherapy superficial treatment within a minimally shielded environment due its low energy. PMID:24790622

  18. Air kerma and absorbed dose standards for reference dosimetry in brachytherapy

    PubMed Central

    2014-01-01

    This article reviews recent developments in primary standards for the calibration of brachytherapy sources, with an emphasis on the currently most common photon-emitting radionuclides. The introduction discusses the need for reference dosimetry in brachytherapy in general. The following section focuses on the three main quantities, i.e. reference air kerma rate, air kerma strength and absorbed dose rate to water, which are currently used for the specification of brachytherapy photon sources and which can be realized with primary standards from first principles. An overview of different air kerma and absorbed dose standards, which have been independently developed by various national metrology institutes over the past two decades, is given in the next two sections. Other dosimetry techniques for brachytherapy will also be discussed. The review closes with an outlook on a possible transition from air kerma to absorbed dose to water-based calibrations for brachytherapy sources in the future. PMID:24814696

  19. MO-E-BRD-01: Is Non-Invasive Image-Guided Breast Brachytherapy Good?

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Hiatt, J.

    2015-06-15

    Is Non-invasive Image-Guided Breast Brachytherapy Good? – Jess Hiatt, MS Non-invasive Image-Guided Breast Brachytherapy (NIBB) is an emerging therapy for breast boost treatments as well as Accelerated Partial Breast Irradiation (APBI) using HDR surface breast brachytherapy. NIBB allows for smaller treatment volumes while maintaining optimal target coverage. Considering the real-time image-guidance and immobilization provided by the NIBB modality, minimal margins around the target tissue are necessary. Accelerated Partial Breast Irradiation in brachytherapy: is shorter better? - Dorin Todor, PhD VCU A review of balloon and strut devices will be provided together with the origins of APBI: the interstitial multi-catheter implant.more » A dosimetric and radiobiological perspective will help point out the evolution in breast brachytherapy, both in terms of devices and the protocols/clinical trials under which these devices are used. Improvements in imaging, delivery modalities and convenience are among the factors driving the ultrashort fractionation schedules but our understanding of both local control and toxicities associated with various treatments is lagging. A comparison between various schedules, from a radiobiological perspective, will be given together with a critical analysis of the issues. to review and understand the evolution and development of APBI using brachytherapy methods to understand the basis and limitations of radio-biological ‘equivalence’ between fractionation schedules to review commonly used and proposed fractionation schedules Intra-operative breast brachytherapy: Is one stop shopping best?- Bruce Libby, PhD. University of Virginia A review of intraoperative breast brachytherapy will be presented, including the Targit-A and other trials that have used electronic brachytherapy. More modern approaches, in which the lumpectomy procedure is integrated into an APBI workflow, will also be discussed. Learning Objectives: To review past and

  20. High brachytherapy doses can counteract hypoxia in cervical cancer—a modelling study

    NASA Astrophysics Data System (ADS)

    Lindblom, Emely; Dasu, Alexandru; Beskow, Catharina; Toma-Dasu, Iuliana

    2017-01-01

    Tumour hypoxia is a well-known adverse factor for the outcome of radiotherapy. For cervical tumours in particular, several studies indicate large variability in tumour oxygenation. However, clinical evidence shows that the management of cervical cancer including brachytherapy leads to high rate of success. It was the purpose of this study to investigate whether the success of brachytherapy for cervical cancer, seemingly regardless of oxygenation status, could be explained by the characteristics of the brachytherapy dose distributions. To this end, a previously used in silico model of tumour oxygenation and radiation response was further developed to simulate the treatment of cervical cancer employing a combination of external beam radiotherapy and intracavitary brachytherapy. Using a clinically-derived brachytherapy dose distribution and assuming a homogeneous dose delivered by external radiotherapy, cell survival was assessed on voxel level by taking into account the variation of sensitivity with oxygenation as well as the effects of repair, repopulation and reoxygenation during treatment. Various scenarios were considered for the conformity of the brachytherapy dose distribution to the hypoxic region in the target. By using the clinically-prescribed brachytherapy dose distribution and varying the total dose delivered with external beam radiotherapy in 25 fractions, the resulting values of the dose for 50% tumour control, D 50, were in agreement with clinically-observed values for high cure rates if fast reoxygenation was assumed. The D 50 was furthermore similar for the different degrees of conformity of the brachytherapy dose distribution to the tumour, regardless of whether the hypoxic fraction was 10%, 25%, or 40%. To achieve 50% control with external RT only, a total dose of more than 70 Gy in 25 fractions would be required for all cases considered. It can thus be concluded that the high doses delivered in brachytherapy can counteract the increased

  1. Temporal relationship between prostate brachytherapy and the diagnosis of colorectal cancer

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Gutman, Sarah A.; Merrick, Gregory S.; Butler, Wayne M.

    2006-09-01

    Purpose: To identify the location of pretreatment and posttreatment colorectal malignancies and posttreatment colorectal polyps in patients with clinically localized prostate cancer managed with brachytherapy. Methods and Materials: From April 1995 through July 2004, 1,351 consecutive patients underwent brachytherapy for clinical stage T1b-T3a (American Joint Committee on Cancer, 2002) prostate cancer. Supplemental external beam radiotherapy (XRT) was administered to 699 patients. The median follow-up was 4.6 years. Operative and pathology reports were reviewed for all patients with pretreatment and posttreatment colorectal cancer and posttreatment colorectal polyps. Multiple parameters were evaluated for the development of colorectal cancer or colorectal polyps. Results:more » Colorectal cancer was diagnosed in 23 and 25 patients before and after prostate brachytherapy, respectively. No differences were identified in the distribution of colorectal cancers either before or after treatment (3 and 4 rectal cancers in the pre- and postbrachytherapy cohorts). Thirty-five of the 48 colorectal cancers (73%) were diagnosed within 5 years of brachytherapy with a peak incidence 1 year after brachytherapy. One hundred ninety-two colorectal polyps were diagnosed after brachytherapy, 160 (83%) occurred within 4 years of brachytherapy, and only 27 (14%) were located in the rectum. In multivariate Cox regression analysis, prostate D{sub 9} (minimum percentage of the dose covering 90% of the target volume) predicted for posttreatment colorectal cancer. Rectal polyps were most closely related to patient age and percent positive biopsies, whereas sigmoid/colon polyps were best predicted by patient age, planning volume, and supplemental XRT. Conclusions: Colorectal cancer was diagnosed with equal frequency before and after brachytherapy with comparable geographic distributions. In addition, the vast majority of postbrachytherapy colorectal polyps were located beyond the confines

  2. Detection of cylinder unbalance from Bayesian inference combining cylinder pressure and vibration block measurement in a Diesel engine

    NASA Astrophysics Data System (ADS)

    Nguyen, Emmanuel; Antoni, Jerome; Grondin, Olivier

    2009-12-01

    In the automotive industry, the necessary reduction of pollutant emission for new Diesel engines requires the control of combustion events. This control is efficient provided combustion parameters such as combustion occurrence and combustion energy are relevant. Combustion parameters are traditionally measured from cylinder pressure sensors. However this kind of sensor is expensive and has a limited lifetime. Thus this paper proposes to use only one cylinder pressure on a multi-cylinder engine and to extract combustion parameters from the other cylinders with low cost knock sensors. Knock sensors measure the vibration circulating on the engine block, hence they do not all contain the information on the combustion processes, but they are also contaminated by other mechanical noises that disorder the signal. The question is how to combine the information coming from one cylinder pressure and knock sensors to obtain the most relevant combustion parameters in all engine cylinders. In this paper, the issue is addressed trough the Bayesian inference formalism. In that cylinder where a cylinder pressure sensor is mounted, combustion parameters will be measured directly. In the other cylinders, they will be measured indirectly from Bayesian inference. Experimental results obtained on a four cylinder Diesel engine demonstrate the effectiveness of the proposed algorithm toward that purpose.

  3. [Aerobic vaginitis--diagnostic problems and treatment].

    PubMed

    Romanik, Małgorzata; Wojciechowska-Wieja, Anna; Martirosian, Gayane

    2007-06-01

    The diagnostic criteria and treatment of aerobic vaginitis--AV--have been summarized in this review. An expansion of mixed aerobic microflora, especially Group B Streptococcus--GBS, Escherichia coli--E. coli, Enterococcus spp., and the development of inflammation of the vaginal mucous membrane due to a decreasing amount of Lactobacillus spp., have been observed in women with AV. Disruptions of the vaginal ecosystem during AV cause an increase in pH to >6, a decrease in lactates concentration and an increase in proinflammatory cytokines concentration in vaginal discharge. An optimal treatment scheme for AV, which includes antibacterial agents and simultaneously normalizes the vaginal ecosystem, has not been established until today.

  4. Focal surfaces of hyperbolic cylinders

    NASA Astrophysics Data System (ADS)

    Georgiev, Georgi Hristov; Pavlov, Milen Dimov

    2017-12-01

    Cylindrical surfaces have many applications in geometric modeling, architecture and other branches of engineering. In this paper, we describe two cylindrical surfaces associated to a given hyperbolic cylinder. The first one is a focal surface which is determined by reciprocal principle curvature of the hyperbolic cylinder. The second one is a generalized focal surface obtained by reciprocal mean curvature of the same hyperbolic cylinder. In particular, we show that each of these surfaces admits three different parametric representations. As consequence, it is proved that the focal and generalized focal surfaces of the hyperbolic cylinder are rational surfaces. An illustrative example is included.

  5. LDR vs. HDR brachytherapy for localized prostate cancer: the view from radiobiological models.

    PubMed

    King, Christopher R

    2002-01-01

    Permanent LDR brachytherapy and temporary HDR brachytherapy are competitive techniques for clinically localized prostate radiotherapy. Although a randomized trial will likely never be conducted comparing these two forms of brachytherapy, a comparative radiobiological modeling analysis proves useful in understanding some of their intrinsic differences, several of which could be exploited to improve outcomes. Radiobiological models based upon the linear quadratic equations are presented for fractionated external beam, fractionated (192)Ir HDR brachytherapy, and (125)I and (103)Pd LDR brachytherapy. These models incorporate the dose heterogeneities present in brachytherapy based upon patient-derived dose volume histograms (DVH) as well as tumor doubling times and repair kinetics. Radiobiological parameters are normalized to correspond to three accepted clinical risk factors based upon T-stage, PSA, and Gleason score to compare models with clinical series. Tumor control probabilities (TCP) for LDR and HDR brachytherapy (as monotherapy or combined with external beam) are compared with clinical bNED survival rates. Predictions are made for dose escalation with HDR brachytherapy regimens. Model predictions for dose escalation with external beam agree with clinical data and validate the models and their underlying assumptions. Both LDR and HDR brachytherapy achieve superior tumor control when compared with external beam at conventional doses (<70 Gy), but similar to results from dose escalation series. LDR brachytherapy as boost achieves superior tumor control than when used as monotherapy. Stage for stage, both LDR and current HDR regimens achieve similar tumor control rates, in agreement with current clinical data. HDR monotherapy with large-dose fraction sizes might achieve superior tumor control compared with LDR, especially if prostate cancer possesses a high sensitivity to dose fractionation (i.e., if the alpha/beta ratio is low). Radiobiological models support the

  6. Calculated and measured brachytherapy dosimetry parameters in water for the Xoft Axxent X-Ray Source: an electronic brachytherapy source.

    PubMed

    Rivard, Mark J; Davis, Stephen D; DeWerd, Larry A; Rusch, Thomas W; Axelrod, Steve

    2006-11-01

    A new x-ray source, the model S700 Axxent X-Ray Source (Source), has been developed by Xoft Inc. for electronic brachytherapy. Unlike brachytherapy sources containing radionuclides, this Source may be turned on and off at will and may be operated at variable currents and voltages to change the dose rate and penetration properties. The in-water dosimetry parameters for this electronic brachytherapy source have been determined from measurements and calculations at 40, 45, and 50 kV settings. Monte Carlo simulations of radiation transport utilized the MCNP5 code and the EPDL97-based mcplib04 cross-section library. Inter-tube consistency was assessed for 20 different Sources, measured with a PTW 34013 ionization chamber. As the Source is intended to be used for a maximum of ten treatment fractions, tube stability was also assessed. Photon spectra were measured using a high-purity germanium (HPGe) detector, and calculated using MCNP. Parameters used in the two-dimensional (2D) brachytherapy dosimetry formalism were determined. While the Source was characterized as a point due to the small anode size, < 1 mm, use of the one-dimensional (1D) brachytherapy dosimetry formalism is not recommended due to polar anisotropy. Consequently, 1D brachytherapy dosimetry parameters were not sought. Calculated point-source model radial dose functions at gP(5) were 0.20, 0.24, and 0.29 for the 40, 45, and 50 kV voltage settings, respectively. For 1

  7. Variation in uterus position prior to brachytherapy of the cervix: A case report.

    PubMed

    Georgescu, M T; Anghel, R

    2017-01-01

    Rationale: brachytherapy is administered in the treatment of patients with locally advanced cervical cancer following chemoradiotherapy. Lack of local anatomy evaluation prior to this procedure might lead to the selection of an inappropriate brachytherapy applicator, increasing the risk of side effects (e.g. uterus perforation, painful procedure ...). Objective: To assess the movement of the uterus and cervix prior to brachytherapy in patients with gynecological cancer, in order to select the proper type of brachytherapy applicator. Also we wanted to promote the replacement of the plain X-ray brachytherapy with the image-guided procedure. Methods and results: We presented the case of a 41-year-old female diagnosed with a biopsy that was proven cervical cancer stage IIIB. At diagnosis, the imaging studies identified an anteverted uterus. The patient underwent preoperative chemoradiotherapy. Prior to brachytherapy, the patient underwent a pelvic magnetic resonance imaging (MRI), which identified a displacement of the uterus in the retroverted position. Discussion: A great variety of brachytherapy applicators is available nowadays. Major changes in uterus position and lack of evaluation prior to brachytherapy might lead to a higher rate of incidents during this procedure. Also, by using orthogonal simulation and bidimensional (2D) treatment planning, brachytherapy would undoubtedly fail to treat the remaining tumoral tissue. This is the reason why we proposed the implementation of a prior imaging of the uterus and computed tomography (CT)/ MRI-based simulation in the brachytherapy procedure. Abbreviations: MRI = magnetic resonance imaging, CT = computed tomography, CTV = clinical target volume, DVH = dose-volume histogram, EBRT = external beam radiotherapy, GTV = gross tumor volume, Gy = Gray (unit), ICRU = International Commission of Radiation Units, IGRT = image guided radiotherapy, IM = internal margin, IMRT = image modulated radiotherapy, ITV = internal target

  8. Advantages of high-dose rate (HDR) brachytherapy in treatment of prostate cancer

    NASA Astrophysics Data System (ADS)

    Molokov, A. A.; Vanina, E. A.; Tseluyko, S. S.

    2017-09-01

    One of the modern methods of preserving organs radiation treatment is brachytherapy. This article analyzes the results of prostate brachytherapy. These studies of the advantages of high dose brachytherapy lead to the conclusion that this method of radiation treatment for prostate cancer has a favorable advantage in comparison with remote sensing methods, and is competitive, preserving organs in comparison to surgical methods of treatment. The use of the method of polyfocal transperineal biopsy during the brachytherapy session provides information on the volumetric spread of prostate cancer and adjust the dosimetry plan taking into account the obtained data.

  9. The evolution of brachytherapy for prostate cancer.

    PubMed

    Zaorsky, Nicholas G; Davis, Brian J; Nguyen, Paul L; Showalter, Timothy N; Hoskin, Peter J; Yoshioka, Yasuo; Morton, Gerard C; Horwitz, Eric M

    2017-06-30

    Brachytherapy (BT), using low-dose-rate (LDR) permanent seed implantation or high-dose-rate (HDR) temporary source implantation, is an acceptable treatment option for select patients with prostate cancer of any risk group. The benefits of HDR-BT over LDR-BT include the ability to use the same source for other cancers, lower operator dependence, and - typically - fewer acute irritative symptoms. By contrast, the benefits of LDR-BT include more favourable scheduling logistics, lower initial capital equipment costs, no need for a shielded room, completion in a single implant, and more robust data from clinical trials. Prospective reports comparing HDR-BT and LDR-BT to each other or to other treatment options (such as external beam radiotherapy (EBRT) or surgery) suggest similar outcomes. The 5-year freedom from biochemical failure rates for patients with low-risk, intermediate-risk, and high-risk disease are >85%, 69-97%, and 63-80%, respectively. Brachytherapy with EBRT (versus brachytherapy alone) is an appropriate approach in select patients with intermediate-risk and high-risk disease. The 10-year rates of overall survival, distant metastasis, and cancer-specific mortality are >85%, <10%, and <5%, respectively. Grade 3-4 toxicities associated with HDR-BT and LDR-BT are rare, at <4% in most series, and quality of life is improved in patients who receive brachytherapy compared with those who undergo surgery.

  10. Underuse of brachytherapy for the treatment of dysphagia owing to esophageal cancer. An Italian survey.

    PubMed

    Fuccio, Lorenzo; Guido, Alessandra; Hassan, Cesare; Frazzoni, Leonardo; Arcelli, Alessandra; Farioli, Andrea; Giaccherini, Lucia; Galuppi, Andrea; Mandolesi, Daniele; Cellini, Francesco; Mantello, Giovanna; Macchia, Gabriella; de Bortoli, Nicola; Repici, Alessandro; Valentini, Vincenzo; Bazzoli, Franco; Morganti, Alessio Giuseppe

    2016-10-01

    International guidelines strongly recommend brachytherapy as valid alternative or in addition to stenting in patients with dysphagia owing to esophageal cancer. However, for not well understood reasons, brachytherapy is definitively underused for the palliative treatment of malignant dysphagia. Aim of the current survey was to investigate the use of brachytherapy for the treatment of malignant dysphagia in Italy. A structured questionnaire was submitted to the 1510 members of the Italian Association of Radiation Oncologists (AIRO). These members refer to 177 centres of radiotherapy across Italy and in 68 (38.4%) of them brachytherapy is routinely performed. Of the 1510 invited members, 178 completed the survey (11.7%). The answers provided by the 178 participants allowed to get information on 40 out of 68 brachytherapy centres (58.8%). Seven out of 40 (17.5%) centres perform brachytherapy of the oesophagus, in 3 out of 40 (7.5%) centres brachytherapy represents the first line of treatment. The main reason why brachytherapy is not routinely performed is the lack of experience. Despite the strong recommendations of the international guidelines and the wide diffusion of brachytherapy centres across Italy, only very few of them routinely considered brachytherapy for the treatment of dysphagia due to esophageal cancer. Copyright © 2016 Editrice Gastroenterologica Italiana S.r.l. Published by Elsevier Ltd. All rights reserved.

  11. Numerical investigation of flow past 17-cylinder array of square cylinders

    NASA Astrophysics Data System (ADS)

    Shams-ul-Islam, Nazeer, Ghazala; Ying, Zhou Chao

    2018-06-01

    In this work, flow past 17-cylinder array is simulated using the two-dimensional lattice Boltzmann method. Effect of gap spacings (0.5 ≤ gx* ≤ 3, 0.5 ≤ gy* ≤ 3) and Reynolds number (Re = 75 - 150) is analyzed in details. Results are presented in the form of vorticity contours plots, time-histories of drag and lift coefficients and power spectrum of lift coefficient. Six distinct flow regimes are identified for different gap spacings and Reynolds numbers: steady flow regime, single bluff body flow regime, non-fully developed flow regime, chaotic flow regime, quasi-periodic-I flow regime and quasi-periodic-II flow regime. Chaotic flow regime is the mostly observed flow regime while the single bluff body flow regime rarely occurs for this configuration. It is observed that drag force along each cylinder in 17-cylinder array decreases in the streamwise direction for fixed Reynold number and gap spacing. C1 and C2 cylinders experience the maximum drag at small gap spacing and Reynolds number. Also the Reynolds number is found to be more effective on flow characteristics as compared to gap spacings.

  12. Brachytherapy for Buccal Cancer: From Conventional Low Dose Rate (LDR) or Mold Technique to High Dose Rate Interstitial Brachytherapy (HDR-ISBT).

    PubMed

    Kotsuma, Tadayuki; Yamazaki, Hideya; Masui, Koji; Yoshida, Ken; Shimizutani, Kimishige; Akiyama, Hironori; Murakami, Shumei; Isohashi, Fumiaki; Yoshioka, Yasuo; Ogawa, Kazuhiko; Tanaka, Eiichi

    2017-12-01

    To examine the effectiveness of newly-installed high-dose-rate interstitial brachytherapy (HDR-ISBT) for buccal cancer. We retrospectively reviewed 36 patients (25 men and 11 women) with buccal cancer treated with curative brachytherapy with or without external radiotherapy with a median follow-up of 99 months. A total of 15 HDR-ISBT (median 48 Gy/ 8 fractions, range=24-60 Gy) patients were compared to conventional 15 cases LDR-ISBT (70 Gy, range=42.8-110 Gy) and 7 molds techniques (15 Gy, range=9-74 Gy). A total of 31 patients also underwent external radiotherapy (30 Gy, range=24-48 Gy). They comprised of 3T1, 23 T2, 8 T3, 3 T4 including 11 node positive cases. HDR-ISBT provided 82% of local control rate at 5 years, whereas conventional brachytherapy showed 72% [p=0.44; LDR-ISBT (65%), mold therapy (85.7%)]. Patients with early lesions (T1-2 or stage I-II) showed better local control rates than those with advanced lesions (T3-4 or stage III-IV). Severe late grade 3 complications developed in two patients treated with LDR-ISBT and EBRT. There is no significant difference in toxicity grade ≤2 between conventional brachytherapy (5/15=33%) and HDR-ISBT (7/32=32%, p=0.92). HDR-ISBT achieved good and comparable local control rates to conventional brachytherapy without elevating the toxicity. Copyright© 2017, International Institute of Anticancer Research (Dr. George J. Delinasios), All rights reserved.

  13. Recurrent vaginal discharge in children.

    PubMed

    McGreal, Sharon; Wood, Paul

    2013-08-01

    Childhood vaginal discharge remains a frequent reason for referral from primary to secondary care. The Pediatric and Adolescent Gynecology (PAG) service at Kettering General Hospital was established in 1993 and provides a specialized service that meets the needs of children with gynaecological conditions. To investigate recurrent vaginal discharge noting symptomatology, defining pathogens, common and rarer causes, exploring management regimes, and any changes in practice over time. Retrospective review spanning 15 years identifying prepubertal children attending the outpatient PAG clinic with recurrent vaginal discharge. We reviewed the medical notes individually. 110 patients were identified; 85% were referred from primary care. The age distribution was bimodal at four and eight years. Thirty-five percent of our patients were discharged after the initial consultation. The commonest cause of discharge was vulvovaginitis (82%). Other important causes included suspected sexual abuse (5%), foreign body (3%), labial adhesions (3%), vaginal agenesis (2%). 35% of patients were admitted for vaginoscopy. Vaginal discharge is the most common gynecological symptom in prepubertal girls and can cause repeated clinical episodes. Vulvovaginitis is the most common cause and often responds to simple hygiene measures. Awareness of the less common causes of vaginal discharge is essential. Copyright © 2013 North American Society for Pediatric and Adolescent Gynecology. Published by Elsevier Inc. All rights reserved.

  14. Brachytherapy Improves Survival in Stage III Endometrial Cancer With Cervical Involvement

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Bingham, Brian; Orton, Andrew; Boothe, Dustin

    Purpose: To evaluate the survival benefit of adding vaginal brachytherapy (BT) to pelvic external beam radiation therapy (EBRT) in women with stage III endometrial cancer. Methods and Materials: The National Cancer Data Base was used to identify patients with stage III endometrial cancer from 2004 to 2013. Only women who received adjuvant EBRT were analyzed. Women were grouped according to receipt of BT. Logistic regression modeling was used to identify predictors of receiving BT. Log–rank statistics were used to compare survival outcomes. Cox proportional hazards modeling was used to evaluate the effect of BT on survival. A propensity score–matched analysismore » was also conducted among women with cervical involvement. Results: We evaluated 12,988 patients with stage III endometrial carcinoma, 39% of whom received EBRT plus BT. Women who received BT were more likely to have endocervical or cervical stromal involvement (odds ratios 2.03 and 1.77; P<.01, respectively). For patients receiving EBRT alone, the 5-year survival was 66% versus 69% with the addition of BT at 5 years (P<.01). Brachytherapy remained significantly predictive of decreased risk of death (hazard ratio 0.86; P<.01) on multivariate Cox regression. The addition of BT to EBRT did not affect survival among women without cervical involvement (P=.84). For women with endocervical or cervical stromal invasion, the addition of BT significantly improved survival (log–rank P<.01). Receipt of EBRT plus BT was associated with improved survival in women with positive and negative surgical margins, and receiving chemotherapy did not alter the benefit of BT. Propensity score–matched analysis results confirmed the benefit of BT among women with cervical involvement (hazard ratio 0.80; P=.01). Conclusions: In this population of women with stage III endometrial cancer the addition of BT to EBRT was associated with an improvement in survival for women with endocervical or cervical stromal invasion.« less

  15. Oncentra brachytherapy planning system.

    PubMed

    Yang, Jack

    2018-03-27

    In modern cancer management, treatment planning has progressed as a contemporary tool with all the advances in computing power in recent years. One of the advanced planning tools uses 3-dimensional (3D) data sets for accurate dose distributions in patient prescription. Among these planning processes, brachytherapy has been a very important part of a successful cancer management program, offering clinical benefits with specific or combined treatments with external beam therapy. In this chapter, we mainly discussed the Elekta Oncentra planning system, which is the main treatment planning tool for high-dose rate (HDR) modality in our facility and in many other facilities in the United States. HDR is a technically advanced form of brachytherapy; a high-intensity radiation source (3.6 mm in length) is delivered with step motor in submillimeter precision under computer guidance directly into the tumor areas while minimizing injury to surrounding normal healthy tissue. Oncentra planning is the key component to generate a deliverable brachytherapy procedure, which is executed on the microSelectron V3 remote afterloader treatment system. Creating a highly conformal plan can be a time-consuming task. The development of Oncentra software (version 4.5.3) offers a variety of useful tools that facilitate many of the clinical challenging tasks for planning, such as contouring and image reconstruction, as well as rapid planning calculations with dose and dose volume histogram analysis. Oncentra Brachy module creates workflow and optimizes the planning accuracy for wide varieties of clinical HDR treatments, such as skin, gynecologic (GYN), breast, prostate, and many other applications. The treatment file can also be transferred to the afterloader control station for speedy delivery. The design concept, calculation algorithms, and optimization modules presented some key characteristics to plan and treat the patients effectively and accurately. The dose distribution and accuracy of

  16. Secretory Aspartyl Proteinases Cause Vaginitis and Can Mediate Vaginitis Caused by Candida albicans in Mice

    PubMed Central

    Pericolini, Eva; Gabrielli, Elena; Amacker, Mario; Kasper, Lydia; Roselletti, Elena; Luciano, Eugenio; Sabbatini, Samuele; Kaeser, Matthias; Moser, Christian; Hube, Bernhard; Vecchiarelli, Anna

    2015-01-01

    ABSTRACT Vaginal inflammation (vaginitis) is the most common disease caused by the human-pathogenic fungus Candida albicans. Secretory aspartyl proteinases (Sap) are major virulence traits of C. albicans that have been suggested to play a role in vaginitis. To dissect the mechanisms by which Sap play this role, Sap2, a dominantly expressed member of the Sap family and a putative constituent of an anti-Candida vaccine, was used. Injection of full-length Sap2 into the mouse vagina caused local neutrophil influx and accumulation of the inflammasome-dependent interleukin-1β (IL-1β) but not of inflammasome-independent tumor necrosis factor alpha. Sap2 could be replaced by other Sap, while no inflammation was induced by the vaccine antigen, the N-terminal-truncated, enzymatically inactive tSap2. Anti-Sap2 antibodies, in particular Fab from a human combinatorial antibody library, inhibited or abolished the inflammatory response, provided the antibodies were able, like the Sap inhibitor Pepstatin A, to inhibit Sap enzyme activity. The same antibodies and Pepstatin A also inhibited neutrophil influx and cytokine production stimulated by C. albicans intravaginal injection, and a mutant strain lacking SAP1, SAP2, and SAP3 was unable to cause vaginal inflammation. Sap2 induced expression of activated caspase-1 in murine and human vaginal epithelial cells. Caspase-1 inhibition downregulated IL-1β and IL-18 production by vaginal epithelial cells, and blockade of the IL-1β receptor strongly reduced neutrophil influx. Overall, the data suggest that some Sap, particularly Sap2, are proinflammatory proteins in vivo and can mediate the inflammasome-dependent, acute inflammatory response of vaginal epithelial cells to C. albicans. These findings support the notion that vaccine-induced or passively administered anti-Sap antibodies could contribute to control vaginitis. PMID:26037125

  17. A new surgical approach of temporary ovarian transposition for children undergoing brachytherapy: technical assessment and dose evaluation.

    PubMed

    de Lambert, Guénolée; Haie-Meder, Christine; Guérin, Florent; Boubnova, Julia; Martelli, Hélène

    2014-07-01

    We developed a new technique of temporary ovarian transposition (OT) for prepubertal girls undergoing brachytherapy. The aim of this study was to describe it, assess its feasibility and safety and calculate the dose delivered to the ovary in order to prove its efficacy. Sixteen prepubertal patients underwent temporary OT for brachytherapy at our center from March 2001 to December 2012. OT was done either by laparotomy or by laparoscopy. In all patients, the ovaries were grasped with an atraumatic forceps and mobilized above the iliac crest level as high as possible without any dissection or division of the ovarian ligaments or of the fallopian tube. They were sutured to the anterior abdominal wall by a transfixing stitch of non-dissolvable suture knotted on the outside of the patient on a pledget. Median age at surgery was 3 years (range: 2-9 years). The integrity of the fallopian tube was respected and not a single ligament was dissected or divided. None of the patients had intraoperative or postoperative complications. The stitches were retrieved after completion of irradiation and the ovaries in all the patients fell back into the pelvis. The calculated median radiation dose to the ovary was 1.4 Gy (range: 0.4-2.4 Gy). This surgical technique is simple and safe, either by laparotomy or by laparoscopy. It meets the radiation and physical constraints in prepubertal girls with vaginal or bladder RMS. However, longer follow-up is required to assess the ovarian function. Copyright © 2014 Elsevier Inc. All rights reserved.

  18. MO-FG-210-00: US Guided Systems for Brachytherapy

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    NONE

    Ultrasound (US) is one of the most widely used imaging modalities in medical practice. Since US imaging offers real-time imaging capability, it has becomes an excellent option to provide image guidance for brachytherapy (IGBT). (1) The physics and the fundamental principles of US imaging are presented, and the typical steps required to commission an US system for IGBT is provided for illustration. (2) Application of US for prostate HDR brachytherapy, including partial prostate treatments using MR-ultrasound co-registration to enable a focused treatment on the disease within the prostate is also presented. Prostate HDR with US image guidance planning can benefitmore » from real time visualization of the needles, and fusion of the ultrasound images with T2 weighted MR allows the focusing of the treatment to the specific areas of disease within the prostate, so that the entire gland need not be treated. Finally, (3) ultrasound guidance for an eye plaque program is presented. US can be a key component of placement and QA for episcleral plaque brachytherapy for ocular cancer, and the UCLA eye plaque program with US for image guidance is presented to demonstrate the utility of US verification of plaque placement in improving the methods and QA in episcleral plaque brachytherapy. Learning Objectives: To understand the physics of an US system and the necessary aspects of commissioning US for image guided brachytherapy (IGBT). To understand real time planning of prostate HDR using ultrasound, and its application in partial prostate treatments using MR-ultrasound fusion to focus treatment on disease within the prostate. To understand the methods and QA in applying US for localizing the target and the implant during a episcleral plaque brachytherapy procedures.« less

  19. 21 CFR 884.5920 - Vaginal insufflator.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Vaginal insufflator. 884.5920 Section 884.5920 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED... § 884.5920 Vaginal insufflator. (a) Identification. A vaginal insufflator is a device used to treat...

  20. Quantitative studies on the vaginal flora of asymptomatic women and patients with vaginitis and vaginosis.

    PubMed

    Hammann, R; Kronibus, A; Lang, N; Werner, H

    1987-07-01

    Vaginal washings of 22 patients with vaginitis, 11 with vaginosis, and 12 healthy subjects were investigated quantitatively and qualitatively for aerobic and anaerobic bacteria and yeasts. Gardnerella vaginalis was recovered from 9 of the vaginitis patients, 7 of the vaginosis patients, and 4 of the asymptomatic subjects. Obligate anaerobes were found in 11 of the vaginitis patients, 4 of the vaginosis patients, and none of the control subjects. Bacteroides bivius was the anaerobe most frequently isolated from symptomatic subjects. Anaerobic vibrios were recovered twice from symptomatic subjects. The counts for Gardnerella vaginalis and anaerobes when present were generally very high. The most frequent aerobes were beta-hemolytic streptococci (group B) and staphylococci.

  1. Vaginitis

    MedlinePlus

    ... discharge usually is thin and dark or dull gray, but may have a greenish color. Itching is ... trichomoniasis? Signs of trichomoniasis may include a yellow-gray or green vaginal discharge. The discharge may have ...

  2. Massless rotating fermions inside a cylinder

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Ambruş, Victor E., E-mail: victor.ambrus@gmail.com; Winstanley, Elizabeth

    2015-12-07

    We study rotating thermal states of a massless quantum fermion field inside a cylinder in Minkowski space-time. Two possible boundary conditions for the fermion field on the cylinder are considered: the spectral and MIT bag boundary conditions. If the radius of the cylinder is sufficiently small, rotating thermal expectation values are finite everywhere inside the cylinder. We also study the Casimir divergences on the boundary. The rotating thermal expectation values and the Casimir divergences have different properties depending on the boundary conditions applied at the cylinder. This is due to the local nature of the MIT bag boundary condition, whilemore » the spectral boundary condition is nonlocal.« less

  3. Efficient visual grasping alignment for cylinders

    NASA Technical Reports Server (NTRS)

    Nicewarner, Keith E.; Kelley, Robert B.

    1992-01-01

    Monocular information from a gripper-mounted camera is used to servo the robot gripper to grasp a cylinder. The fundamental concept for rapid pose estimation is to reduce the amount of information that needs to be processed during each vision update interval. The grasping procedure is divided into four phases: learn, recognition, alignment, and approach. In the learn phase, a cylinder is placed in the gripper and the pose estimate is stored and later used as the servo target. This is performed once as a calibration step. The recognition phase verifies the presence of a cylinder in the camera field of view. An initial pose estimate is computed and uncluttered scan regions are selected. The radius of the cylinder is estimated by moving the robot a fixed distance toward the cylinder and observing the change in the image. The alignment phase processes only the scan regions obtained previously. Rapid pose estimates are used to align the robot with the cylinder at a fixed distance from it. The relative motion of the cylinder is used to generate an extrapolated pose-based trajectory for the robot controller. The approach phase guides the robot gripper to a grasping position. The cylinder can be grasped with a minimal reaction force and torque when only rough global pose information is initially available.

  4. Efficient visual grasping alignment for cylinders

    NASA Technical Reports Server (NTRS)

    Nicewarner, Keith E.; Kelley, Robert B.

    1991-01-01

    Monocular information from a gripper-mounted camera is used to servo the robot gripper to grasp a cylinder. The fundamental concept for rapid pose estimation is to reduce the amount of information that needs to be processed during each vision update interval. The grasping procedure is divided into four phases: learn, recognition, alignment, and approach. In the learn phase, a cylinder is placed in the gripper and the pose estimate is stored and later used as the servo target. This is performed once as a calibration step. The recognition phase verifies the presence of a cylinder in the camera field of view. An initial pose estimate is computed and uncluttered scan regions are selected. The radius of the cylinder is estimated by moving the robot a fixed distance toward the cylinder and observing the change in the image. The alignment phase processes only the scan regions obtained previously. Rapid pose estimates are used to align the robot with the cylinder at a fixed distance from it. The relative motion of the cylinder is used to generate an extrapolated pose-based trajectory for the robot controller. The approach phase guides the robot gripper to a grasping position. The cylinder can be grasped with a minimal reaction force and torque when only rough global pose information is initially available.

  5. 21 CFR 884.3575 - Vaginal pessary.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Vaginal pessary. 884.3575 Section 884.3575 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL... Vaginal pessary. (a) Identification. A vaginal pessary is a removable structure placed in the vagina to...

  6. Comparison of the hypothetical 57Co brachytherapy source with the 192Ir source

    PubMed Central

    Toossi, Mohammad Taghi Bahreyni; Rostami, Atefeh; Khosroabadi, Mohsen; Khademi, Sara; Knaup, Courtney

    2016-01-01

    Aim of the study The 57Co radioisotope has recently been proposed as a hypothetical brachytherapy source due to its high specific activity, appropriate half-life (272 days) and medium energy photons (114.17 keV on average). In this study, Task Group No. 43 dosimetric parameters were calculated and reported for a hypothetical 57Co source. Material and methods A hypothetical 57Co source was simulated in MCNPX, consisting of an active cylinder with 3.5 mm length and 0.6 mm radius encapsulated in a stainless steel capsule. Three photon energies were utilized (136 keV [10.68%], 122 keV [85.60%], 14 keV [9.16%]) for the 57Co source. Air kerma strength, dose rate constant, radial dose function, anisotropy function, and isodose curves for the source were calculated and compared to the corresponding data for a 192Ir source. Results The results are presented as tables and figures. Air kerma strength per 1 mCi activity for the 57Co source was 0.46 cGyh–1 cm 2 mCi–1. The dose rate constant for the 57Co source was determined to be 1.215 cGyh–1U–1. The radial dose function for the 57Co source has an increasing trend due to multiple scattering of low energy photons. The anisotropy function for the 57Co source at various distances from the source is more isotropic than the 192Ir source. Conclusions The 57Co source has advantages over 192Ir due to its lower energy photons, longer half-life, higher dose rate constant and more isotropic anisotropic function. However, the 192Ir source has a higher initial air kerma strength and more uniform radial dose function. These properties make 57Co a suitable source for use in brachytherapy applications. PMID:27688731

  7. Elevated vaginal pH in the absence of current vaginal infection, still a challenging obstetrical problem.

    PubMed

    Hantoushzadeh, Sedigheh; Sheikh, Mahdi; Javadian, Pouya; Shariat, Mamak; Amini, Elaheh; Abdollahi, Alireza; Kashanian, Maryam

    2014-04-01

    To assess the association of vaginal pH ≥ 5 in the absence of vaginal infection with systemic inflammation and adverse pregnancy outcome. Four-hundred sixty pregnant women completed the study, upon enrollment Vaginal pH was measured for all women, maternal and umbilical sera were obtained for determining C-reactive protein (CRP) and uric acid levels. Umbilical blood was tested for gas parameters, 1 and 5 min Apgar scores, the need for neonatal resuscitation and neonatal intensive care unit (NICU) admission were recorded. Elevated vaginal pH was significantly associated with preterm birth (odds ratio (OR), 2.23; 95% confidence interval (CI), 1.04-4.76), emergency cesarean section (OR 2.57; 95% CI 1.32-5), neonatal resuscitation in the delivery room (OR 2.85; 95% CI 1.1-7.38), elevated cord base deficit (OR 8.01; 95% CI 1.61-39.81), low cord bicarbonate (OR 4.16, 95% CI 1.33-12.92) and NICU admission (OR 2.02; 95% CI 1.12-3.66). Increased vaginal pH was also significantly associated with maternal leukocytosis, hyperuricemia and elevated CRP levels in maternal and umbilical sera. Elevated vaginal pH in the absence of current vaginal infection still constitutes a risk for adverse pregnancy outcome which is mediated by systemic inflammatory response.

  8. Vaginal eroticism: a replication study.

    PubMed

    Alzate, H

    1985-12-01

    Vaginal eroticism was investigated in a group of 27 coitally experienced volunteers by means of systematic digital stimulation of both vaginal walls. Erogenous zones were found in all subjects, mainly located on the upper anterior wall and the lower posterior one. An orgasmic response was elicited by stimulation of these zones in 89% of the subjects. This study supports previous findings regarding vaginal eroticism. It does not support the existence of the discrete anatomical structure called the Grafenberg spot. It supports the contention that there are two distinct types of female orgasm, vaginally evoked and clitorally evoked. It also supports the finding that some women expel a fluid through the urethra at the time of orgasm. In this particular case the fluid was chemically indistinguishable from urine.

  9. Disease-specific survival following the brachytherapy management of prostate cancer.

    PubMed

    Stock, Richard G; Cesaretti, Jamie A; Stone, Nelson N

    2006-03-01

    To determine disease-specific survival (DSS) and associated predictive factors after prostate brachytherapy. A total of 1561 patients underwent brachytherapy for prostate cancer from 1990 to 2004 (median follow-up, 3.8 years). Treatment included brachytherapy alone (n = 634), brachytherapy and hormonal therapy (n = 420), and implant and external beam therapy (n = 507). The DSS and overall survival rates at 10 years were 96% and 74%, respectively. Gleason score significantly impacted DSS, with 10-year rates of 98%, 91%, and 92% for scores of < or = 6, 7, and > or = 8, respectively (p < 0.0001). Multivariate analysis revealed that PSA status after treatment had the most significant effect on DSS. Ten-year DSS rates were 100%, 52%, and 98%, respectively for patients without PSA failure (n = 1430), failure with a doubling time (DT) < or = 10 months (n = 64), and failure with a DT > 10 months (n = 67), respectively (p < 0.0001). In patients with PSA failure, DSS rates were 30%, 67%, and 98%, for those with DT < or = 6 months, > 6-10 months, and > 10 months, respectively (p < 0.0001). The 10-year DSS rate supports the efficacy of brachytherapy. Patients dying with disease within 10 years after treatment harbor inherently aggressive cancer with high Gleason scores and short DT.

  10. Comparison of outcomes between operative vaginal deliveries and spontaneous vaginal deliveries in southeast Nigeria.

    PubMed

    Lawani, Lucky O; Anozie, Okechukwu B; Ezeonu, Paul O; Iyoke, Chukwuemeka A

    2014-06-01

    To evaluate the incidence of, indications for, and outcome of operative vaginal deliveries compared with spontaneous vaginal deliveries in southeast Nigeria. A retrospective cohort study was conducted involving cases of operative vaginal delivery performed at Ebonyi State University Teaching Hospital over a 10-year period. Data on the procedures were abstracted from the operation notes of the medical records of parturients. An incidence of 4.7% (n = 461) was recorded. The most common indications for vacuum and forceps delivery were prolonged second stage of labor (44.9%) and poor maternal effort (27.8%). The only indication for destructive operation was intrauterine fetal death (3.7%). The risk ratio (RR) for hemorrhage/vulvar hematoma was 1.14 (95% confidence interval [CI], 0.53-2.48) for vacuum-assisted delivery and 5.49 (95% CI, 0.82-36.64) for forceps delivery. The RR for genital laceration was 1.21 (95% CI, 0.44-3.30) for vacuum-assisted delivery and 9.41 (95% CI, 1.33-66.65) for forceps delivery. The risk of fetal scalp bruises and caput succedaneum was higher for operative vaginal delivery than for spontaneous vaginal delivery, with no significant difference in maternal morbidity. The perinatal mortality rate was 0.9 per 1000 live births. Operative vaginal delivery by experienced healthcare providers is associated with good obstetric outcomes with minimal risk. Copyright © 2014 International Federation of Gynecology and Obstetrics. Published by Elsevier Ireland Ltd. All rights reserved.

  11. Relativistic Bessel cylinders

    NASA Astrophysics Data System (ADS)

    Krisch, J. P.; Glass, E. N.

    2014-10-01

    A set of cylindrical solutions to Einstein's field equations for power law densities is described. The solutions have a Bessel function contribution to the metric. For matter cylinders regular on axis, the first two solutions are the constant density Gott-Hiscock string and a cylinder with a metric Airy function. All members of this family have the Vilenkin limit to their mass per length. Some examples of Bessel shells and Bessel motion are given.

  12. MO-E-BRD-02: Accelerated Partial Breast Irradiation in Brachytherapy: Is Shorter Better?

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Todor, D.

    2015-06-15

    Is Non-invasive Image-Guided Breast Brachytherapy Good? – Jess Hiatt, MS Non-invasive Image-Guided Breast Brachytherapy (NIBB) is an emerging therapy for breast boost treatments as well as Accelerated Partial Breast Irradiation (APBI) using HDR surface breast brachytherapy. NIBB allows for smaller treatment volumes while maintaining optimal target coverage. Considering the real-time image-guidance and immobilization provided by the NIBB modality, minimal margins around the target tissue are necessary. Accelerated Partial Breast Irradiation in brachytherapy: is shorter better? - Dorin Todor, PhD VCU A review of balloon and strut devices will be provided together with the origins of APBI: the interstitial multi-catheter implant.more » A dosimetric and radiobiological perspective will help point out the evolution in breast brachytherapy, both in terms of devices and the protocols/clinical trials under which these devices are used. Improvements in imaging, delivery modalities and convenience are among the factors driving the ultrashort fractionation schedules but our understanding of both local control and toxicities associated with various treatments is lagging. A comparison between various schedules, from a radiobiological perspective, will be given together with a critical analysis of the issues. to review and understand the evolution and development of APBI using brachytherapy methods to understand the basis and limitations of radio-biological ‘equivalence’ between fractionation schedules to review commonly used and proposed fractionation schedules Intra-operative breast brachytherapy: Is one stop shopping best?- Bruce Libby, PhD. University of Virginia A review of intraoperative breast brachytherapy will be presented, including the Targit-A and other trials that have used electronic brachytherapy. More modern approaches, in which the lumpectomy procedure is integrated into an APBI workflow, will also be discussed. Learning Objectives: To review past and

  13. ALGEBRA: ALgorithm for the heterogeneous dosimetry based on GEANT4 for BRAchytherapy.

    PubMed

    Afsharpour, H; Landry, G; D'Amours, M; Enger, S; Reniers, B; Poon, E; Carrier, J-F; Verhaegen, F; Beaulieu, L

    2012-06-07

    Task group 43 (TG43)-based dosimetry algorithms are efficient for brachytherapy dose calculation in water. However, human tissues have chemical compositions and densities different than water. Moreover, the mutual shielding effect of seeds on each other (interseed attenuation) is neglected in the TG43-based dosimetry platforms. The scientific community has expressed the need for an accurate dosimetry platform in brachytherapy. The purpose of this paper is to present ALGEBRA, a Monte Carlo platform for dosimetry in brachytherapy which is sufficiently fast and accurate for clinical and research purposes. ALGEBRA is based on the GEANT4 Monte Carlo code and is capable of handling the DICOM RT standard to recreate a virtual model of the treated site. Here, the performance of ALGEBRA is presented for the special case of LDR brachytherapy in permanent prostate and breast seed implants. However, the algorithm is also capable of handling other treatments such as HDR brachytherapy.

  14. Dynamic modulated brachytherapy (DMBT) and intensity modulated brachytherapy (IMBT) for the treatment of rectal and breast carcinomas

    NASA Astrophysics Data System (ADS)

    Webster, Matthew Julian

    The ultimate goal of any treatment of cancer is to maximize the likelihood of killing the tumor while minimizing the chance of damaging healthy tissues. One of the most effective ways to accomplish this is through radiation therapy, which must be able to target the tumor volume with a high accuracy while minimizing the dose delivered to healthy tissues. A successful method of accomplishing this is brachytherapy which works by placing the radiation source in very close proximity to the tumor. However, most current applications of brachytherapy rely mostly on the geometric manipulation of isotropic sources, which limits the ability to specifically target the tumor. The purpose of this work is to introduce several types of shielded brachytherapy applicators which are capable of targeting tumors with much greater accuracy than existing technologies. These applicators rely on the modulation of the dose profile through a high-density tungsten alloy shields to create anisotropic dose distributions. Two classes of applicators have been developed in this work. The first relies on the active motion of the shield, to aim a highly directional radiation profile. This allows for very precise control of the dose distribution for treatment, achieving unparalleled dose coverage to the tumor while sparing healthy tissues. This technique has been given the moniker of Dynamic Modulated Brachytherapy (DMBT). The second class of applicators, designed to reduce treatment complexity uses static applicators. These applicators retain the use of the tungsten shield, but the shield is motionless during treatment. By intelligently designing the shield, significant improvements over current methods have been demonstrated. Although these static applicators fail to match the dosimetric quality of DMBT applicators the simplified setup and treatment procedure gives them significant appeal. The focus of this work has been to optimize these shield designs, specifically for the treatment of rectal and

  15. Desquamative inflammatory vaginitis. A review.

    PubMed Central

    Oates, J K; Rowen, D

    1990-01-01

    Desquamative inflammatory vaginitis is an uncommon cause of an intractable vaginitis often accompanied by serious dyspareunia, which can occur at any stage of reproductive life and after the menopause. The cytological changes are identical with those seen in atrophic vaginitis yet the disorder often occurs in the presence of apparently normal ovarian function. Vaginal synechiae and stenosis develop in an appreciable number of patients. Treatment is unsatisfactory though there is some response to either local or systemic steroid therapy. The literature is reviewed and the association of some cases with lichen planus of the mouth and genitals discussed. Its causation and natural history remain largely unknown and there is as yet, insufficient evidence to regard it as a single entity. It is likely that the incidence of the disorder is underestimated. PMID:2202657

  16. Human vaginal pH and microbiota: an update.

    PubMed

    Godha, Keshav; Tucker, Kelly M; Biehl, Colton; Archer, David F; Mirkin, Sebastian

    2018-06-01

    A woman's vaginal pH has many implications on her health and it can be a useful tool in disease diagnosis and prevention. For that reason, the further examination of the relationship between the human vaginal pH and microbiota is imperative. In the past several decades, much has been learned about the physiological mechanisms modulating the vaginal pH, and exogenous/genetic factors that may influence it. A unified, coherent understanding of these concepts is presented to comprehend their interrelationships and their cumulative effect on a woman's health. In this review, we explore research on vaginal pH and microbiota throughout a woman's life, vaginal intermediate cell anaerobic metabolism and net proton secretion by the vaginal epithelial, and the way these factors interact to acidify the vaginal pH. This review provides foundational information about what a microbiota is and its relationship with human physiology and vaginal pH. We then evaluate the influence of physiological mechanisms, demographic factors, and propose ideas for the mechanisms behind their action on the vaginal pH.

  17. Directional interstitial brachytherapy from simulation to application

    NASA Astrophysics Data System (ADS)

    Lin, Liyong

    Organs at risk (OAR) are sometimes adjacent to or embedded in or overlap with the clinical target volume (CTV) to be treated. The purpose of this PhD study is to develop directionally low energy gamma-emitting interstitial brachytherapy sources. These sources can be applied between OAR to selectively reduce hot spots in the OARs and normal tissues. The reduction of dose over undesired regions can expand patient eligibility or reduce toxicities for the treatment by conventional interstitial brachytherapy. This study covers the development of a directional source from design optimization to construction of the first prototype source. The Monte Carlo code MCNP was used to simulate the radiation transport for the designs of directional sources. We have made a special construction kit to assemble radioactive and gold-shield components precisely into D-shaped titanium containers of the first directional source. Directional sources have a similar dose distribution as conventional sources on the treated side but greatly reduced dose on the shielded side, with a sharp dose gradient between them. A three-dimensional dose deposition kernel for the 125I directional source has been calculated. Treatment plans can use both directional and conventional 125I sources at the same source strength for low-dose-rate (LDR) implants to optimize the dose distributions. For prostate tumors, directional 125I LDR brachytherapy can potentially reduce genitourinary and gastrointestinal toxicities and improve potency preservation for low risk patients. The combination of better dose distribution of directional implants and better therapeutic ratio between tumor response and late reactions enables a novel temporary LDR treatment, as opposed to permanent or high-dose-rate (HDR) brachytherapy for the intermediate risk T2b and high risk T2c tumors. Supplemental external-beam treatments can be shortened with a better brachytherapy boost for T3 tumors. In conclusion, we have successfully finished the

  18. Contemporary Toxicity Profile of Breast Brachytherapy Versus External Beam Radiation After Lumpectomy for Breast Cancer

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Huo, Jinhai; Giordano, Sharon H.; Department of Breast Medical Oncology, The University of Texas MD Anderson Cancer Center, Houston, Texas

    Purpose: We compared toxicities after brachytherapy versus external beam radiation therapy (EBRT) in contemporary breast cancer patients. Methods and Materials: Using MarketScan healthcare claims, we identified 64,112 women treated from 2003 to 2012 with lumpectomy followed by radiation (brachytherapy vs EBRT). Brachytherapy was further classified by multichannel versus single-channel applicator approach. We identified the risks and predictors of 1-year infectious and noninfectious postoperative adverse events using logistic regression and temporal trends using Cochran-Armitage tests. We estimated the 5-year Kaplan-Meier cumulative incidence of radiation-associated adverse events. Results: A total of 4522 (7.1%) patients received brachytherapy (50.2% multichannel vs 48.7% single-channel applicator).more » The overall risk of infectious adverse events was higher after brachytherapy than after EBRT (odds ratio [OR] = 1.21; 95% confidence interval [CI] 1.09-1.34, P<.001). However, over time, the frequency of infectious adverse events after brachytherapy decreased, from 17.3% in 2003 to 11.6% in 2012, and was stable after EBRT at 9.7%. Beyond 2007, there were no longer excess infections with brachytherapy (P=.97). The overall risk of noninfectious adverse events was higher after brachytherapy than after EBRT (OR=2.27; 95% CI 2.09-2.47, P<.0001). Over time, the frequency of noninfectious adverse events detected increased: after multichannel brachytherapy, from 9.1% in 2004 to 18.9% in 2012 (Ptrend = .64); single-channel brachytherapy, from 12.8% to 29.8% (Ptrend<.001); and EBRT, from 6.1% to 10.3% (Ptrend<.0001). The risk was significantly higher with single-channel than with multichannel brachytherapy (hazard ratio = 1.32; 95% CI 1.03-1.69, P=.03). Of noninfectious adverse events, 70.9% were seroma. Seroma significantly increased breast pain risk (P<.0001). Patients with underlying diabetes, cardiovascular disease, and treatment with chemotherapy had increased

  19. Bacterial vaginosis and vaginal yeast, but not vaginal cleansing, increase HIV-1 acquisition in African women.

    PubMed

    van de Wijgert, Janneke H H M; Morrison, Charles S; Cornelisse, Peter G A; Munjoma, Marshall; Moncada, Jeanne; Awio, Peter; Wang, Jing; Van der Pol, Barbara; Chipato, Tsungai; Salata, Robert A; Padian, Nancy S

    2008-06-01

    To evaluate interrelationships between bacterial vaginosis (BV), vaginal yeast, vaginal practices (cleansing and drying/tightening), mucosal inflammation, and HIV acquisition. A multicenter, prospective, observational cohort study was conducted, enrolling 4531 HIV-negative women aged 18 to 35 years attending family planning clinics in Zimbabwe and Uganda. Participants were tested for HIV and reproductive tract infections and were interviewed about vaginal practices every 3 months for 15 to 24 months. BV was measured by Gram stain Nugent scoring, vaginal yeast by wet mount, and mucosal inflammation by white blood cells on Gram stain. HIV incidence was 4.12 and 1.53 per 100 woman-years of follow-up in Zimbabwe and Uganda, respectively (a total of 213 incident infections). Women with BV or vaginal yeast were more likely to acquire HIV, especially if the condition was present at the same visit as the new HIV infection and the visit preceding it (hazard ratio [HR] = 2.50, 95% confidence interval [CI]: 1.68 to 3.72 and HR = 2.97, 95% CI: 1.67 to 5.28 for BV and yeast, respectively). These relationships did not seem to be mediated by mucosal inflammation. Vaginal drying/tightening was associated with HIV acquisition in univariate (HR = 1.49, 95% CI: 1.03 to 2.15) but not multivariate models. Vaginal cleansing was not associated with HIV acquisition. BV and yeast may contribute more to the HIV epidemic than previously thought.

  20. A novel multiport cylinder dryer.

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Choi, S. U.; Yu, W.; France, D. M.

    2001-02-01

    A multiport dryer design concept that could create breakthroughs in the drying of pulp and paper is under development. The feasibility of this novel concept was demonstrated in a proof-of-concept test. Experiments were performed in a specially designed test apparatus to investigate the condensing heat-transfer characteristics of a single channel (representative of a multiport cylinder dryer) under typical operating conditions. The experimental results showed that multiport cylinder-dryer technology provides very high heat-transfer coefficients of 15,000 W/m{sup 2}{center_dot}K (2600 Btu/h{center_dot}ft{sup 2} {sup o}F) and a highly uniform distribution of cylinder-wall temperature. These experimental results suggest that a multiport cylinder dryer canmore » increase the rate of paper drying compared with a conventional cylinder dryer. The increased dryer efficiency translates into either a reduction in the number of dryers at the same level of production or an increase in the rate of production with the same number of dryers.« less

  1. General Information about Vaginal Cancer

    MedlinePlus

    ... Research Vaginal Cancer Treatment (PDQ®)–Patient Version General Information About Vaginal Cancer Go to Health Professional Version ... the PDQ Adult Treatment Editorial Board . Clinical Trial Information A clinical trial is a study to answer ...

  2. [Clinical characteristics of aerobic vaginitis and its mixed infections].

    PubMed

    Fan, Ai-Ping; Xue, Feng-Xia

    2010-12-01

    To investigate clinical characteristics of aerobic vaginitis (AV) and its mixed infections for diagnosis efficiently. From April 2008 to December 2008, 516 patients with vaginitis treated in Tianjin Medical University General Hospital were enrolled in this study. AV, bacterial vaginosis (BV), vulvovaginal candidiasis (VVC), trichomonal vaginitis (TV), and cytolytic vaginosis (CV) were diagnosed based on symptoms, sign and vaginal discharge examination. Among 516 cases, AV cases were found in 14.7% (76/516), and AV was common vaginal infection. AV mixed infections was diagnosed in 58% (44/76), including mixed with BV (45%, 20/44), mixed with VVC (30%, 13/44), and mixed with TV (25%, 11/44). Those common symptom of AV were yellow vaginal discharge (63%, 20/32), more vaginal discharge (44%, 14/32). Vaginal pH value was usually more than 4.5 (84%, 27/32). Vaginal cleanliness mainly was grade III - IV (88%, 28/32). Six cases with enterococcus faecium and 4 cases with streptococci were frequently isolated. The symptom and sign of mixed AV infection was atypical. Aerobic vaginitis is a common lower vaginal infection and easily mixed with other pathogens, especially with BV, VVC or TV. When patients were diagnosed with AV or other vaginal infection, it should be mentioned whether those patients have mixed vaginal infection or AV.

  3. Inverse Planning Approach for 3-D MRI-Based Pulse-Dose Rate Intracavitary Brachytherapy in Cervix Cancer

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Chajon, Enrique; Dumas, Isabelle; Touleimat, Mahmoud B.Sc.

    2007-11-01

    Purpose: The purpose of this study was to evaluate the inverse planning simulated annealing (IPSA) software for the optimization of dose distribution in patients with cervix carcinoma treated with MRI-based pulsed-dose rate intracavitary brachytherapy. Methods and Materials: Thirty patients treated with a technique using a customized vaginal mold were selected. Dose-volume parameters obtained using the IPSA method were compared with the classic manual optimization method (MOM). Target volumes and organs at risk were delineated according to the Gynecological Brachytherapy Group/European Society for Therapeutic Radiology and Oncology recommendations. Because the pulsed dose rate program was based on clinical experience with lowmore » dose rate, dwell time values were required to be as homogeneous as possible. To achieve this goal, different modifications of the IPSA program were applied. Results: The first dose distribution calculated by the IPSA algorithm proposed a heterogeneous distribution of dwell time positions. The mean D90, D100, and V100 calculated with both methods did not differ significantly when the constraints were applied. For the bladder, doses calculated at the ICRU reference point derived from the MOM differed significantly from the doses calculated by the IPSA method (mean, 58.4 vs. 55 Gy respectively; p = 0.0001). For the rectum, the doses calculated at the ICRU reference point were also significantly lower with the IPSA method. Conclusions: The inverse planning method provided fast and automatic solutions for the optimization of dose distribution. However, the straightforward use of IPSA generated significant heterogeneity in dwell time values. Caution is therefore recommended in the use of inverse optimization tools with clinical relevance study of new dosimetric rules.« less

  4. HDR-192Ir intraluminal brachytherapy in treatment of malignant obstructive jaundice

    PubMed Central

    Chen, Yi; Wang, Xiao-Lin; Yan, Zhi-Ping; Cheng, Jie-Min; Wang, Jian-Hua; Gong, Gao-Quan; Qian, Sheng; Luo, Jian-Jun; Liu, Qing-Xin

    2004-01-01

    AIM: To determine the feasibility and safety of intraluminal brachytherapy in treatment of malignant obstructive jaundice (MOJ) and to evaluate the clinical effect of intraluminal brachytherapy on stent patency and patient survival. METHODS: Thirty-four patients with MOJ were included in this study. Having biliary stent placed, all patients were classified into intraluminal brachytherapy group (group A, n = 14) and control group (group B, n = 20) according to their own choice. Intraluminal brachytherapy regimen included: HDR-192Ir was used in the therapy, fractional doses of 4-7 Gy were given every 3-6 d for 3-4 times, and standard points were established at 0.5-1.0 cm. Some patients of both groups received transcatheter arterial chemoembolization (TACE) after stent placement. RESULTS: In group A, the success rate of intraluminal brachytherapy was 98.0%, RTOG grade 1 acute radiation morbidity occurred in 3 patients, RTOG/EORTC grade 1 late radiation morbidity occurred in 1 patient. Mean stent patency of group A (12.6 mo) was significantly longer than that of group B (8.3 mo) (P < 0.05). There was no significant difference in the mean survival (9.4 mo vs 6.0 mo) between the two groups. CONCLUSION: HDR-192Ir intraluminal brachytherapy is a safe palliative therapy in treating MOJ, and it may prolong stent patency and has the potentiality of extending survival of patients with MOJ. PMID:15526374

  5. Vaginal bleeding in late pregnancy

    MedlinePlus

    ... this page: //medlineplus.gov/ency/patientinstructions/000627.htm Vaginal bleeding in late pregnancy To use the sharing ... JavaScript. One out of 10 women will have vaginal bleeding during their 3rd trimester. At times, it ...

  6. Multi-cylinder hot gas engine

    DOEpatents

    Corey, John A.

    1985-01-01

    A multi-cylinder hot gas engine having an equal angle, V-shaped engine block in which two banks of parallel, equal length, equally sized cylinders are formed together with annular regenerator/cooler units surrounding each cylinder, and wherein the pistons are connected to a single crankshaft. The hot gas engine further includes an annular heater head disposed around a central circular combustor volume having a new balanced-flow hot-working-fluid manifold assembly that provides optimum balanced flow of the working fluid through the heater head working fluid passageways which are connected between each of the cylinders and their respective associated annular regenerator units. This balanced flow provides even heater head temperatures and, therefore, maximum average working fluid temperature for best operating efficiency with the use of a single crankshaft V-shaped engine block.

  7. Multiple Cylinder Free-Piston Stirling Machinery

    NASA Astrophysics Data System (ADS)

    Berchowitz, David M.; Kwon, Yong-Rak

    In order to improve the specific power of piston-cylinder type machinery, there is a point in capacity or power where an advantage accrues with increasing number of piston-cylinder assemblies. In the case of Stirling machinery where primary energy is transferred across the casing wall of the machine, this consideration is even more important. This is due primarily to the difference in scaling of basic power and the required heat transfer. Heat transfer is found to be progressively limited as the size of the machine increases. Multiple cylinder machines tend to preserve the surface area to volume ratio at more favorable levels. In addition, the spring effect of the working gas in the so-called alpha configuration is often sufficient to provide a high frequency resonance point that improves the specific power. There are a number of possible multiple cylinder configurations. The simplest is an opposed pair of piston-displacer machines (beta configuration). A three-cylinder machine requires stepped pistons to obtain proper volume phase relationships. Four to six cylinder configurations are also possible. A small demonstrator inline four cylinder alpha machine has been built to demonstrate both cooling operation and power generation. Data from this machine verifies theoretical expectations and is used to extrapolate the performance of future machines. Vibration levels are discussed and it is argued that some multiple cylinder machines have no linear component to the casing vibration but may have a nutating couple. Example applications are discussed ranging from general purpose coolers, computer cooling, exhaust heat power extraction and some high power engines.

  8. [Brachytherapy in France: current situation and economic outlook due to the unavailability of iridium wires].

    PubMed

    Le Vu, B; Boucher, S

    2014-10-01

    In 2013, about 6000 patients were treated with brachytherapy, the number diminishing by 2.6% per year since 2008. Prostate, breast and gynecological cancers are the most common types of cancers. Since 2008, the number of brachytherapy facilities has decreased by 18%. In medicoeconomic terms, brachytherapy faces many problems: the coding system is outdated; brachytherapy treatments cost as much as internal radiation; fees do not cover costs; since iridium wire has disappeared from the market, the technique will be transferred to more expensive high-speed or pulse dose rates. The French financing grid based on the national study of costs lags behind changes in such treatments and in the best of cases, hospitals resorting to alternatives such as in-hospital brachytherapy are funded at 46% of their additional costs. Brachytherapy is a reference technique. With intense pressure on hospital pricing, financing brachytherapy facilities will become even more problematic as a consequence of the disappearance of iridium 192 wires. The case of brachytherapy illustrates the limits of the French financing system and raises serious doubts as to its responsiveness. Copyright © 2014 Société française de radiothérapie oncologique (SFRO). Published by Elsevier SAS. All rights reserved.

  9. Imaging System for Vaginal Surgery.

    PubMed

    Taylor, G Bernard; Myers, Erinn M

    2015-12-01

    The vaginal surgeon is challenged with performing complex procedures within a surgical field of limited light and exposure. The video telescopic operating microscope is an illumination and imaging system that provides visualization during open surgical procedures with a limited field of view. The imaging system is positioned within the surgical field and then secured to the operating room table with a maneuverable holding arm. A high-definition camera and Xenon light source allow transmission of the magnified image to a high-definition monitor in the operating room. The monitor screen is positioned above the patient for the surgeon and assistants to view real time throughout the operation. The video telescopic operating microscope system was used to provide surgical illumination and magnification during total vaginal hysterectomy and salpingectomy, midurethral sling, and release of vaginal scar procedures. All procedures were completed without complications. The video telescopic operating microscope provided illumination of the vaginal operative field and display of the magnified image onto high-definition monitors in the operating room for the surgeon and staff to simultaneously view the procedures. The video telescopic operating microscope provides high-definition display, magnification, and illumination during vaginal surgery.

  10. Natural convective heat transfer from square cylinder

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Novomestský, Marcel, E-mail: marcel.novomestsky@fstroj.uniza.sk; Smatanová, Helena, E-mail: helena.smatanova@fstroj.uniza.sk; Kapjor, Andrej, E-mail: andrej.kapjor@fstroj.uniza.sk

    This article is concerned with natural convective heat transfer from square cylinder mounted on a plane adiabatic base, the cylinders having an exposed cylinder surface according to different horizontal angle. The cylinder receives heat from a radiating heater which results in a buoyant flow. There are many industrial applications, including refrigeration, ventilation and the cooling of electrical components, for which the present study may be applicable.

  11. A Sequence of Cylinders

    ERIC Educational Resources Information Center

    Johnson, Erica

    2006-01-01

    Hoping to develop in her students an understanding of mathematics as a way of thinking more than a way of doing, the author of this article describes how her students worked on a spatial reasoning problem stemming from an iteratively constructed sequence of cylinders. She presents an activity of making cylinders out of paper models, and for every…

  12. Low-Dose-Rate Brachytherapy Versus Cryotherapy in Low- and Intermediate-Risk Prostate Cancer

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Gestaut, Matthew M., E-mail: Matthew.Gestaut@BSWHealth.org; Cai, Wendi; Vyas, Shilpa

    Purpose: Cryotherapy and brachytherapy are definitive local treatment options for low- to intermediate-risk prostate cancer. There are both prospective and retrospective data for brachytherapy, but the use of cryotherapy has been limited primarily to single-institution retrospective studies. Currently, no published evidence has compared low-dose-rate brachytherapy versus cryotherapy. Methods and Materials: Institutional review board approval was obtained to conduct a retrospective chart review of consecutive patients treated at our institution from 1990 to 2012. For inclusion, patients must have received a prostate cancer diagnosis and have been considered to have low- to intermediate-risk disease according to the National Comprehensive Cancer Networkmore » criteria. All patients received brachytherapy or cryotherapy treatment. Disease specifics and failure details were collected for all patients. Failure was defined as prostate-specific antigen nadir +2 ng/mL. Results: A total of 359 patients were analyzed. The groups comprised 50 low-risk cryotherapy (LRC), 92 intermediate-risk cryotherapy (IRC), 133 low-risk brachytherapy (LRB), and 84 intermediate-risk brachytherapy (IRB) patients. The median prostate-specific antigen follow-up periods were 85.6 months (LRC), 59.2 months (IRC), 74.9 months (LRB), and 59.8 months (IRB). The 5-year biochemical progression–free survival (bPFS) rate was 57.9% in the cryotherapy group versus 89.6% in the brachytherapy group (P<.0001). The 5-year bPFS rate was 70.0% (LRC), 51.4% (IRC), 89.4% (LRB), and 89.7% (IRB). The bPFS rate was significantly different between brachytherapy and cryotherapy for low- and intermediate-risk groups (P<.05). The mean nadir temperature reached for cryotherapy patients was −35°C (range, −96°C to −6°C). Cryotherapy used a median of 2 freeze-thaw cycles (range, 2-4 freeze-thaw cycles). Conclusions: Results from this study suggest that cryotherapy is inferior to brachytherapy for

  13. WE-E-BRD-01: HDR Brachytherapy I: Overview of Clinical Application and QA

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Libby, B; Showalter, T

    2014-06-15

    With the increased usage of high dose rate (HDR) brachytherapy and the introduction of dedicated image guided brachytherapy suites, it is necessary to review the processes and procedures associated with safely delivering these treatments in the expedited time scales that dedicated treatment suites afford. The speakers will present the clinical aspects of switching from LDR to HDR treatments, including guidelines for patient selection, and the clinical outcomes comparing LDR to HDR. The speakers will also discuss the HDR treatment process itself, because the shortened clinical timeline involved with a streamlined scan/plan/treat workflow can introduce other issues. Safety and QA aspectsmore » involved with the streamlined process, including increased personnel required for parallel tasks, and possible interfering tasks causing delays in patient treatments will also be discussed. Learning Objectives: To understand the clinical aspects of HDR Brachytherapy, including common clinical indications, patient selection, and the evolving evidence in support of this therapeutic modality To review the current prominent clinical trials for HDR brachytherapy To interpret the established guidelines for HDR brachytherapy quality assurance for implementation into practical clinical settings. To introduce the basic requirements for image guided brachytherapy.« less

  14. Magnetic resonance imaging in prostate brachytherapy: Evidence, clinical end points to data, and direction forward.

    PubMed

    Pugh, Thomas J; Pokharel, Sajal S

    The integration of multiparametric MRI into prostate brachytherapy has become a subject of interest over the past 2 decades. MRI directed high-dose-rate and low-dose-rate prostate brachytherapy offers the potential to improve treatment accuracy and standardize postprocedure quality. This article reviews the evidence to date on MRI utilization in prostate brachytherapy and postulates future pathways for MRI integration. Copyright © 2016 American Brachytherapy Society. Published by Elsevier Inc. All rights reserved.

  15. Development of a brachytherapy audit checklist tool.

    PubMed

    Prisciandaro, Joann; Hadley, Scott; Jolly, Shruti; Lee, Choonik; Roberson, Peter; Roberts, Donald; Ritter, Timothy

    2015-01-01

    To develop a brachytherapy audit checklist that could be used to prepare for Nuclear Regulatory Commission or agreement state inspections, to aid in readiness for a practice accreditation visit, or to be used as an annual internal audit tool. Six board-certified medical physicists and one radiation oncologist conducted a thorough review of brachytherapy-related literature and practice guidelines published by professional organizations and federal regulations. The team members worked at two facilities that are part of a large, academic health care center. Checklist items were given a score based on their judged importance. Four clinical sites performed an audit of their program using the checklist. The sites were asked to score each item based on a defined severity scale for their noncompliance, and final audit scores were tallied by summing the products of importance score and severity score for each item. The final audit checklist, which is available online, contains 83 items. The audit scores from the beta sites ranged from 17 to 71 (out of 690) and identified a total of 7-16 noncompliance items. The total time to conduct the audit ranged from 1.5 to 5 hours. A comprehensive audit checklist was developed which can be implemented by any facility that wishes to perform a program audit in support of their own brachytherapy program. The checklist is designed to allow users to identify areas of noncompliance and to prioritize how these items are addressed to minimize deviations from nationally-recognized standards. Copyright © 2015 American Brachytherapy Society. All rights reserved.

  16. Vaginal itching and discharge - child

    MedlinePlus

    ... vulvae; Itching - vaginal area; Vulvar itching; Yeast infection - child ... To prevent and treat vaginal irritation, your child should: Avoid colored or perfumed toilet tissue and bubble bath. Use plain, unscented soap. Limit bath time to 15 minutes or less. Ask ...

  17. Vaginal Microbiota in Pregnancy: Evaluation Based on Vaginal Flora, Birth Outcome, and Race

    PubMed Central

    Subramaniam, Akila; Kumar, Ranjit; Cliver, Suzanne P.; Zhi, Degui; Szychowski, Jeff M.; Abramovici, Adi; Biggio, Joseph R.; Lefkowitz, Elliot J.; Morrow, Casey; Edwards, Rodney K.

    2016-01-01

    Objective This study aims to evaluate vaginal microbiota differences by bacterial vaginosis (BV), birth timing, and race, and to estimate parameters to power future vaginal microbiome studies. Methods Previously, vaginal swabs were collected at 21 to 25 weeks (stored at −80°C), and vaginal smears evaluated for BV (Nugent criteria). In a blinded fashion, 40 samples were selected, creating 8 equal-sized groups stratified by race (black/white), BV (present/absent), and birth timing (preterm/term). Samples were thawed, DNA extracted, and prepared. Polymerase chain reaction (PCR) with primers targeting the 16S rDNA V4 region was used to prepare an amplicon library. PCR products were sequenced and analyzed using quantitative insight into microbial ecology; taxonomy was assigned using ribosomal database program classifier (threshold 0.8) against the modified Greengenes database. Results After quality control, 97,720 sequences (mean) per sample, single-end 250 base-reads, were analyzed. BV samples had greater microbiota diversity (p < 0.05)—with BVAB1, Prevotella, and unclassified genus, Bifidobacteriaceae family (all p < 0.001) more abundant; there was minimal content of Gardnerella or Mobiluncus. Microbiota did not differ by race or birth timing, but there was an association between certain microbial clusters and preterm birth (p = 0.07). To evaluate this difference, 159 patients per group are needed. Conclusions There are differences in the vaginal microbiota between patients with and without BV. Larger studies should assess the relationship between microbiota composition and preterm birth. PMID:26479170

  18. Utilization of prostate brachytherapy for low risk prostate cancer: Is the decline overstated?

    PubMed

    Safdieh, Joseph; Wong, Andrew; Weiner, Joseph P; Schwartz, David; Schreiber, David

    2016-08-01

    Several prior studies have suggested that brachytherapy utilization has markedly decreased, coinciding with the recent increased utilization of intensity modulated radiation therapy, as well as an increase in urologist-owned centers. We sought to investigate the brachytherapy utilization in a large, hospital-based registry. Men with prostate cancer diagnosed between 2004-2012 and treated with either external beam radiation and/or prostate brachytherapy were abstracted from the National Cancer Database. In order to be included, men had to be clinically staged as T1c-T2aNx-0Mx-0, Gleason 6, PSA ≤ 10.0 ng/ml. Descriptive statistics were used to analyze brachytherapy utilization over time and were compared via χ(2). Multivariate logistic regression was used to assess for covariables associated with increased brachytherapy usage. There were 89,413 men included in this study, of which 37,054 (41.6%) received only external beam radiation, and 52,089 (58.4%) received prostate brachytherapy. The use of brachytherapy declined over time from 62.9% in 2004 to 51.3% in 2012 (p < 0.001). This decline was noted in both academic facilities (60.8% in 2004 to 47.0% in 2012, p < 0.001) as well as in non-academic facilities (63.7% in 2004 to 53.0% in 2012, p < 0.001). The decline was more pronounced in patients who lived closer to treatment facilities than those who lived further. The use of intensity modulated radiation therapy increased during this same time period from 18.4% in 2004 to 38.2% in 2012 (p < 0.001). On multivariate analysis, treatment at an academic center, increasing age, decreasing distance from the treatment center, and years of diagnosis from 2006-2012 were significantly associated with reduced brachytherapy usage. In this hospital-based registry, prostate brachytherapy usage has declined for low risk prostate cancer as intensity modulated radiation therapy usage has increased. However, it still remains the treatment of choice for 51.3% of patients as of 2012.

  19. Efficacy of rifaximin vaginal tablets in treatment of bacterial vaginosis: a molecular characterization of the vaginal microbiota.

    PubMed

    Cruciani, Federica; Brigidi, Patrizia; Calanni, Fiorella; Lauro, Vittoria; Tacchi, Raffaella; Donders, Gilbert; Peters, Klaus; Guaschino, Secondo; Vitali, Beatrice

    2012-08-01

    Bacterial vaginosis (BV) is a common vaginal disorder characterized by an alteration of the vaginal bacterial morphotypes, associated with sexually transmitted infections and adverse pregnancy outcomes. The purpose of the present study was to evaluate the impact of different doses of rifaximin vaginal tablets (100 mg/day for 5 days, 25 mg/day for 5 days, and 100 mg/day for 2 days) on the vaginal microbiota of 102 European patients with BV enrolled in a multicenter, double-blind, randomized, placebo-controlled study. An integrated molecular approach based on quantitative PCR (qPCR) and PCR-denaturing gradient gel electrophoresis (PCR-DGGE) was used to investigate the effects of vaginal tablets containing the antibiotic. An increase in members of the genus Lactobacillus and a decrease in the BV-related bacterial groups after the antibiotic treatment were demonstrated by qPCR. PCR-DGGE profiles confirmed the capability of rifaximin to modulate the composition of the vaginal microbial communities and to reduce their complexity. This molecular analysis supported the clinical observation that rifaximin at 25 mg/day for 5 days represents an effective treatment to be used in future pivotal studies for the treatment of BV.

  20. Efficacy of Rifaximin Vaginal Tablets in Treatment of Bacterial Vaginosis: a Molecular Characterization of the Vaginal Microbiota

    PubMed Central

    Cruciani, Federica; Brigidi, Patrizia; Calanni, Fiorella; Lauro, Vittoria; Tacchi, Raffaella; Donders, Gilbert; Peters, Klaus; Guaschino, Secondo

    2012-01-01

    Bacterial vaginosis (BV) is a common vaginal disorder characterized by an alteration of the vaginal bacterial morphotypes, associated with sexually transmitted infections and adverse pregnancy outcomes. The purpose of the present study was to evaluate the impact of different doses of rifaximin vaginal tablets (100 mg/day for 5 days, 25 mg/day for 5 days, and 100 mg/day for 2 days) on the vaginal microbiota of 102 European patients with BV enrolled in a multicenter, double-blind, randomized, placebo-controlled study. An integrated molecular approach based on quantitative PCR (qPCR) and PCR-denaturing gradient gel electrophoresis (PCR-DGGE) was used to investigate the effects of vaginal tablets containing the antibiotic. An increase in members of the genus Lactobacillus and a decrease in the BV-related bacterial groups after the antibiotic treatment were demonstrated by qPCR. PCR-DGGE profiles confirmed the capability of rifaximin to modulate the composition of the vaginal microbial communities and to reduce their complexity. This molecular analysis supported the clinical observation that rifaximin at 25 mg/day for 5 days represents an effective treatment to be used in future pivotal studies for the treatment of BV. PMID:22585228

  1. Sci-Thur PM – Brachytherapy 01: Fast brachytherapy dose calculations: Characterization of egs-brachy features to enhance simulation efficiency

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Chamberland, Marc; Taylor, Randle E.P.; Rogers, Da

    2016-08-15

    Purpose: egs-brachy is a fast, new EGSnrc user-code for brachytherapy applications. This study characterizes egs-brachy features that enhance simulation efficiency. Methods: Calculations are performed to characterize efficiency gains from various features. Simulations include radionuclide and miniature x-ray tube sources in water phantoms and idealized prostate, breast, and eye plaque treatments. Features characterized include voxel indexing of sources to reduce boundary checks during radiation transport, scoring collision kerma via tracklength estimator, recycling photons emitted from sources, and using phase space data to initiate simulations. Bremsstrahlung cross section enhancement (BCSE), uniform bremsstrahlung splitting (UBS), and Russian Roulette (RR) are considered for electronicmore » brachytherapy. Results: Efficiency is enhanced by a factor of up to 300 using tracklength versus interaction scoring of collision kerma and by up to 2.7 and 2.6 using phase space sources and particle recycling respectively compared to simulations in which particles are initiated within sources. On a single 2.5 GHz Intel Xeon E5-2680 processor cor, simulations approximating prostate and breast permanent implant ((2 mm){sup 3} voxels) and eye plaque ((1 mm){sup 3}) treatments take as little as 9 s (prostate, eye) and up to 31 s (breast) to achieve 2% statistical uncertainty on doses within the PTV. For electronic brachytherapy, BCSE, UBS, and RR enhance efficiency by a factor >2000 compared to a factor of >10{sup 4} using a phase space source. Conclusion: egs-brachy features provide substantial efficiency gains, resulting in calculation times sufficiently fast for full Monte Carlo simulations for routine brachytherapy treatment planning.« less

  2. A comparison study on various low energy sources in interstitial prostate brachytherapy.

    PubMed

    Bakhshabadi, Mahdi; Ghorbani, Mahdi; Khosroabadi, Mohsen; Knaup, Courtney; Meigooni, Ali S

    2016-02-01

    Low energy sources are routinely used in prostate brachytherapy. (125)I is one of the most commonly used sources. Low energy (131)Cs source was introduced recently as a brachytherapy source. The aim of this study is to compare dose distributions of (125)I, (103)Pd, and (131)Cs sources in interstitial brachytherapy of prostate. ProstaSeed (125)I brachytherapy source was simulated using MCNPX Monte Carlo code. Additionally, two hypothetical sources of (103)Pd and (131)Cs were simulated with the same geometry as the ProstaSeed (125)I source, while having their specific emitted gamma spectra. These brachytherapy sources were simulated with distribution of forty-eight seeds in a phantom including prostate. The prostate was considered as a sphere with radius of 1.5 cm. Absolute and relative dose rates were obtained in various distances from the source along the transverse and longitudinal axes inside and outside the tumor. Furthermore, isodose curves were plotted around the sources. Analyzing the initial dose profiles for various sources indicated that with the same time duration and air kerma strength, (131)Cs delivers higher dose to tumor. However, relative dose rate inside the tumor is higher and outside the tumor is lower for the (103)Pd source. The higher initial absolute dose in cGy/(h.U) of (131)Cs brachytherapy source is an advantage of this source over the others. The higher relative dose inside the tumor and lower relative dose outside the tumor for the (103)Pd source are advantages of this later brachytherapy source. Based on the total dose the (125)I source has advantage over the others due to its longer half-life.

  3. Clinical approach to vaginal/vestibular masses in the bitch.

    PubMed

    Manothaiudom, K; Johnston, S D

    1991-05-01

    The most common causes of vaginal/vestibular masses in the bitch are vaginal prolapse, vaginal neoplasia, and urethral neoplasia protruding into the vaginal vault. Other possible causes are clitoral enlargement, vaginal polyps, uterine prolapse, and vaginal abscessation or hematoma. Vaginal prolapse usually can be distinguished from neoplasia by the age of the patient, the time of occurrence during the estrous cycle, and the site of origin of the mass. Prolapse usually occurs in bitches under 4 years of age during proestrus, estrus, or at the end of diestrus and usually arises from the floor of the vagina, except for urethral tumors that protrude from the external urethral orifice. Appropriate diagnostic workup of bitches with vaginal vestibular masses includes complete history and physical examination, vaginal cytologic and vaginoscopic examination, retrograde vaginography or urethrocystography, serum progesterone and estradiol concentrations, and, in the case of suspect neoplasms, surgical or excision biopsy of the mass.

  4. Equivalence of expressions for the radiation force on cylinders and application to elliptical cylinders

    NASA Astrophysics Data System (ADS)

    Wei, Wei; Marston, Philip L.

    2005-09-01

    Using an appropriate grouping of terms, a radiation force expression for cylinders in a standing wave based on far-field scattering [W. Wei, D. B. Thiessen, and P. L. Marston, J. Acoust. Soc. Am. 116, 202-208 (2004)] is transformed to an expression given elsewhere [F. G. Mitri, Eur. Phys. J. B 44, 71-78 (2005)]. Mitri's result is from a near-field derivation for the specific case of a circular cylinder. In the usual case, in an ideal lossless media the far-field derivation is not an approximation. The far-field derivation also applies to noncircular objects having mirror symmetry about the incident wave vector. Some general and historical aspects of far-field derivations of optical and acoustical radiation force (going back to 1909) will be noted. Our formulation yields a simple low-frequency approximation for the radiation force on elliptical cylinders by introducing approximations for the partial-wave scattering coefficients of elliptical cylinders first derived by Rayleigh. [Work supported by NASA.

  5. Does vaginal irrigation with saline solution in women with infectious vaginitis contribute to the clinical and microbiological results of antibiotic therapy?

    PubMed

    Derbent, Aysel Uysal; Ulukanlıgil, Mustafa; Keskin, Esra Aktepe; Soylu, Gül; Kafalı, Hasan

    2012-01-01

    To compare the clinical and microbiological results between patients with infectious vaginitis receiving vaginal irrigation with saline or no irrigation before standard antibiotic therapy. Women with vaginitis (n = 109) were randomized to receive vaginal irrigation with saline or no irrigation before standard antibiotic therapy. The vaginal symptoms perceived by subjects and clinical findings were assessed with a standardized scale during four follow-up visits, and Gram stain Nugent scores and vaginal fluid cultures were analyzed at each visit. Vaginal discharge (z = 7.159; p < 0.001), pruritus (z = 5.169; p < 0.001), itching (z = 2.969; p < 0.003) and odor scores (z = 2.303; p < 0.021) were significantly reduced in the study group compared to the control group between the first visit and 3-5 days after irrigation, before the start of antibiotic therapy. The second and third visits (15 and 30-45 days after antibiotic therapy) showed that the patients' symptoms and amounts of visible vaginal discharge did not differ between the two groups. Moreover, the microbiological cures of patients in each group did not differ at these visits (z = 0.447; p = 0.655). Vaginal irrigation with saline significantly reduces self-reported symptoms in the short term but has no effect on long-term clinical and laboratory results in women with infectious vaginitis. Copyright © 2012 S. Karger AG, Basel.

  6. Ocular Response of Choroidal Melanoma With Monosomy 3 Versus Disomy 3 After Iodine-125 Brachytherapy

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Marathe, Omkar S.; Wu, Jeffrey; Lee, Steve P.

    2011-11-15

    Purpose: To report the ocular response of choroidal melanoma with monosomy 3 vs. disomy 3 after {sup 125}I brachytherapy. Methods and Materials: We evaluated patients with ciliochoroidal melanoma managed with fine needle aspiration biopsy immediately before plaque application for {sup 125}I brachytherapy between January 1, 2005 and December 31, 2008. Patients with (1) cytopathologic diagnosis of melanoma, (2) melanoma chromosome 3 status identified by fluorescence in situ hybridization, and (3) 6 or more months of follow-up after brachytherapy were sorted by monosomy 3 vs. disomy 3 and compared by Kruskal-Wallis test. Results: Among 40 ciliochoroidal melanomas (40 patients), 15 hadmore » monosomy 3 and 25 had disomy 3. Monosomy 3 melanomas had a median greatest basal diameter of 12.00 mm and a median tumor thickness of 6.69 mm before brachytherapy; at a median of 1.75 years after brachytherapy, median thickness was 3.10 mm. Median percentage decrease in tumor thickness was 48.3%. Disomy 3 melanomas had a median greatest basal diameter of 10.00 mm and median tumor thickness of 3.19 mm before brachytherapy; at a median of 2.00 years after brachytherapy, median tumor thickness was 2.37 mm. The median percentage decrease in tumor thickness was 22.7%. Monosomy 3 melanomas were statistically greater in size than disomy 3 melanomas (p < 0.001) and showed a greater decrease in tumor thickness after brachytherapy (p = 0.006). Conclusion: In this study, ciliochoroidal melanomas with monosomy 3 were significantly greater in size than disomy 3 melanoma and showed a significantly greater decrease in thickness at a median of 1.75 years after brachytherapy. The greater decrease in monosomy 3 melanoma thickness after brachytherapy is consistent with other malignancies in which more aggressive pathology has been shown to be associated with a greater initial response to radiotherapy.« less

  7. Effects of intrauterine contraception on the vaginal microbiota.

    PubMed

    Bassis, Christine M; Allsworth, Jenifer E; Wahl, Heather N; Sack, Daniel E; Young, Vincent B; Bell, Jason D

    2017-09-01

    There have been conflicting reports of altered vaginal microbiota and infection susceptibility associated with contraception use. The objectives of this study were to determine if intrauterine contraception altered the vaginal microbiota and to compare the effects of a copper intrauterine device (Cu-IUD) and a levonorgestrel intrauterine system (LNG-IUS) on the vaginal microbiota. DNA was isolated from the vaginal swab samples of 76 women using Cu-IUD (n=36) or LNG-IUS (n=40) collected prior to insertion of intrauterine contraception (baseline) and at 6 months. A third swab from approximately 12 months following insertion was available for 69 (Cu-IUD, n=33; LNG-IUS, n=36) of these women. The V4 region of the bacterial 16S rRNA-encoding gene was amplified from the vaginal swab DNA and sequenced. The 16S rRNA gene sequences were processed and analyzed using the software package mothur to compare the structure and dynamics of the vaginal bacterial communities. The vaginal microbiota from individuals in this study clustered into 3 major vaginal bacterial community types: one dominated by Lactobacillus iners, one dominated by Lactobacillus crispatus and one community type that was not dominated by a single Lactobacillus species. Changes in the vaginal bacterial community composition were not associated with the use of Cu-IUD or LNG-IUS. Additionally, we did not observe a clear difference in vaginal microbiota stability with Cu-IUD versus LNG-IUS use. Although the vaginal microbiota can be highly dynamic, alterations in the community associated with the use of intrauterine contraception (Cu-IUD or LNG-IUS) were not detected over 12 months. We found no evidence that intrauterine contraception (Cu-IUD or LNG-IUS) altered the vaginal microbiota composition. Therefore, the use of intrauterine contraception is unlikely to shift the composition of the vaginal microbiota such that infection susceptibility is altered. Copyright © 2017 Elsevier Inc. All rights reserved.

  8. The vaginal microbiome: rethinking health and diseases

    PubMed Central

    Ma, Bing; Forney, Larry J.; Ravel, Jacques

    2013-01-01

    Vaginal microbiota form a mutually beneficial relationship with their host and have major impact on health and disease. In recent years our understanding of vaginal bacterial community composition and structure has significantly broadened as a result of investigators using cultivation-independent methods based on the analysis of 16S ribosomal RNA (rRNA) gene sequences. In asymptomatic, otherwise healthy women, several kinds of vaginal microbiota exist, the majority often dominated by species of Lactobacillus, while others comprise a diverse array of anaerobic microorganisms. Bacterial vaginosis is the most common vaginal conditions and is vaguely characterized as the disruption of the equilibrium of the ‘normal’ vaginal microbiots. A better understanding of ‘normal’ and ‘healthy’ vaginal ecosystems that is based on its ‘true’ function and not simply on its composition would help better define health and further improve disease diagnostics as well as the development of more personalized regimens to promote health and treat diseases. PMID:22746335

  9. In Vitro Activity of Tea Tree Oil Vaginal Suppositories against Candida spp. and Probiotic Vaginal Microbiota.

    PubMed

    Di Vito, Maura; Mattarelli, Paola; Modesto, Monica; Girolamo, Antonietta; Ballardini, Milva; Tamburro, Annunziata; Meledandri, Marcello; Mondello, Francesca

    2015-10-01

    The aim of this work is to evaluate the in vitro microbicidal activity of vaginal suppositories (VS) containing tea tree oil (TTO-VS) towards Candida spp. and vaginal probiotics. A total of 20 Candida spp. strains, taken from patients with vaginitis and from an established type collection, including reference strains, were analysed by using the CLSI microdilution method. To study the action of VS towards the beneficial vaginal microbiota, the sensitivity of Bifidobacterium animalis subsp. lactis (DSM 10140) and Lactobacillus spp. (Lactobacillus casei R-215 and Lactobacillus acidophilus R-52) was tested. Both TTO-VS and TTO showed fungicidal activity against all strains of Candida spp. whereas placebo-VS or the Aloe gel used as controls were ineffective. The study of fractional fungicidal concentrations (FFC) showed synergistic interaction with the association between Amphotericin B and TTO (0.25 to 0.08 µg/ml, respectively) against Candida albicans. Instead, the probiotics were only affected by TTO concentration ≥ 4% v/v, while, at concentrations < 2% v/v, they remained viable. TTO-VS exhibits, in vitro, a selective fungicidal action, slightly affecting only the Bifidobacteriun animalis strain growth belonging to the vaginal microbiota. In vivo studies are needed to confirm the efficacy to prevent acute or recurrent vaginal candidiasis. Copyright © 2015 John Wiley & Sons, Ltd.

  10. Free Surface Wave Interaction with a Horizontal Cylinder

    NASA Astrophysics Data System (ADS)

    Oshkai, P.; Rockwell, D.

    1999-10-01

    Classes of vortex formation from a horizontal cylinder adjacent to an undulating free-surface wave are characterized using high-image-density particle image velocimetry. Instantaneous representations of the velocity field, streamline topology and vorticity patterns yield insight into the origin of unsteady loading of the cylinder. For sufficiently deep submergence of the cylinder, the orbital nature of the wave motion results in multiple sites of vortex development, i.e., onset of vorticity concentrations, along the surface of the cylinder, followed by distinctive types of shedding from the cylinder. All of these concentrations of vorticity then exhibit orbital motion about the cylinder. Their contributions to the instantaneous values of the force coefficients are assessed by calculating moments of vorticity. It is shown that large contributions to the moments and their rate of change with time can occur for those vorticity concentrations having relatively small amplitude orbital trajectories. In a limiting case, collision with the surface of the cylinder can occur. Such vortex-cylinder interactions exhibit abrupt changes in the streamline topology during the wave cycle, including abrupt switching of the location of saddle points in the wave. The effect of nominal depth of submergence of the cylinder is characterized in terms of the time history of patterns of vorticity generated from the cylinder and the free surface. Generally speaking, generic types of vorticity concentrations are formed from the cylinder during the cycle of the wave motion for all values of submergence. The proximity of the free surface, however, can exert a remarkable influence on the initial formation, the eventual strength, and the subsequent motion of concentrations of vorticity. For sufficiently shallow submergence, large-scale vortex formation from the upper surface of the cylinder is inhibited and, in contrast, that from the lower surface of the cylinder is intensified. Moreover

  11. Vaginal foreign body causing recurrent discharge and vaginal stenosis--a case report.

    PubMed

    Gurung, Geeta; Rana, Ashma; Amatya, Archana

    2007-06-01

    Chronic vaginal discharge in children and adolescents is a common gynaecological complaint which is often resistant to antibiotic treatment. We present a 14 years old, premenarcheal girl who presented to us with the complaints of recurrent, foul smelling purulent occasionally blood stained vaginal discharge for eight years, where a foreign body in the upper vagina was found after releasing a dense adhesion of the lower vagina which was unable to detect by pelvic ultrasound.

  12. Streptococcus agalactiae: a vaginal pathogen?

    PubMed

    Maniatis, A N; Palermos, J; Kantzanou, M; Maniatis, N A; Christodoulou, C; Legakis, N J

    1996-03-01

    The significance of Streptococcus agalactiae as an aetiological agent in vaginitis was evaluated. A total of 6226 samples from women who presented with vaginal symptoms was examined. The presence of >10 leucocytes/high-power field (h.p.f.) was taken to be the criterion of active infection. S. agalactiae was isolated from 10.1% of these samples. The isolation rates of other common pathogens such as Candida spp., Gardnerella vaginalis and Trichomonas spp. were 54.1%, 27.2% and 4.2%, respectively, in the same group of patients. In contrast, the isolation rates of these micro-organisms in the group of patients who had no infection (<10 leucocytes/h.p.f.) were 4.2%, 38.3%, 33% and 0.5%, respectively. In the majority of samples from which S. agalactiae was isolated, it was the sole pathogen isolated (83%) and its presence was associated with an inflammatory response in 80% of patients. Furthermore, the relative risk of vaginal infection with S. agalactiae (2.38) in patients with purulent vaginal discharge was greater than that of Candida spp. infection (1.41) and lower than that of Trichomonas spp. infection (8.32). These data suggest that S. agalactiae in symptomatic women with microscopic evidence of inflammation should be considered a causative agent of vaginitis.

  13. Minimal percentage of dose received by 90% of the urethra (%UD90) is the most significant predictor of PSA bounce in patients who underwent low-dose-rate brachytherapy (LDR-brachytherapy) for prostate cancer.

    PubMed

    Tanaka, Nobumichi; Asakawa, Isao; Fujimoto, Kiyohide; Anai, Satoshi; Hirayama, Akihide; Hasegawa, Masatoshi; Konishi, Noboru; Hirao, Yoshihiko

    2012-09-14

    To clarify the significant clinicopathological and postdosimetric parameters to predict PSA bounce in patients who underwent low-dose-rate brachytherapy (LDR-brachytherapy) for prostate cancer. We studied 200 consecutive patients who received LDR-brachytherapy between July 2004 and November 2008. Of them, 137 patients did not receive neoadjuvant or adjuvant androgen deprivation therapy. One hundred and forty-two patients were treated with LDR-brachytherapy alone, and 58 were treated with LDR-brachytherapy in combination with external beam radiation therapy. The cut-off value of PSA bounce was 0.1 ng/mL. The incidence, time, height, and duration of PSA bounce were investigated. Clinicopathological and postdosimetric parameters were evaluated to elucidate independent factors to predict PSA bounce in hormone-naïve patients who underwent LDR-brachytherapy alone. Fifty patients (25%) showed PSA bounce and 10 patients (5%) showed PSA failure. The median time, height, and duration of PSA bounce were 17 months, 0.29 ng/mL, and 7.0 months, respectively. In 103 hormone-naïve patients treated with LDR-brachytherapy alone, and univariate Cox proportional regression hazard model indicated that age and minimal percentage of the dose received by 30% and 90% of the urethra were independent predictors of PSA bounce. With a multivariate Cox proportional regression hazard model, minimal percentage of the dose received by 90% of the urethra was the most significant parameter of PSA bounce. Minimal percentage of the dose received by 90% of the urethra was the most significant predictor of PSA bounce in hormone-naïve patients treated with LDR-brachytherapy alone.

  14. Single-Cylinder Oil-Control Tests of Porous Chrome-Plated Cylinder Barrels for Radial Air-Cooled Engines

    DTIC Science & Technology

    1946-01-01

    plating, it will affect a choke as desired in the cylinder. When the clearance between the anode and the cathode (cylinder barrel) is decreased, an...National Advisory Commltteo for Aeronautics, Cltivel« oid , Ohio. RSFEFKICE3 1. Johnson, Robert L., wad Anderson, Roy I.: S.’.nglo-Cylindor Engine Tests...plating a choke in the bore. Choice la obtained by decreasing the clear- ance between the anode and the cylinder barrel ( cathode ). Taper on anode la

  15. Recommendations of the Spanish brachytherapy group (GEB) of Spanish Society of Radiation Oncology (SEOR) and the Spanish Society of Medical Physics (SEFM) for high-dose rate (HDR) non melanoma skin cancer brachytherapy.

    PubMed

    Rodríguez, S; Arenas, M; Gutierrez, C; Richart, J; Perez-Calatayud, J; Celada, F; Santos, M; Rovirosa, A

    2018-04-01

    Clinical indications of brachytherapy in non-melanoma skin cancers, description of applicators and dosimetry recommendations are described based on the literature review, clinical practice and experience of Spanish Group of Brachytherapy and Spanish Society of Medical Physics reported in the XIV Annual Consensus Meeting on Non Melanoma Skin Cancer Brachytherapy held in Benidorm, Alicante (Spain) on October 21st, 2016. All the recommendations for which consensus was achieved are highlighted in blue. Regular and small surfaces may be treated with Leipzig, Valencia, flap applicators or electronic brachytherapy (EBT). For irregular surfaces, customized molds or interstitial implants should be employed. The dose is prescribed at a maximum depth of 3-4 mm of the clinical target volume/planning target volume (CTV/PTV) in all cases except in flaps or molds in which 5 mm is appropriate. Interstitial brachytherapy should be used for CTV/PTV >5 mm. Different total doses and fraction sizes are used with very similar clinical and toxicity results. Hypofractionation is very useful twice or 3 times a week, being comfortable for patients and practical for Radiotherapy Departments. In interstitial brachytherapy 2 fractions twice a day are applied.

  16. Patterns of cetacean vaginal folds yield insights into functionality

    PubMed Central

    Orbach, Dara N.; Marshall, Christopher D.; Mesnick, Sarah L.; Würsig, Bernd

    2017-01-01

    Complex foldings of the vaginal wall are unique to some cetaceans and artiodactyls and are of unknown function(s). The patterns of vaginal length and cumulative vaginal fold length were assessed in relation to body length and to each other in a phylogenetic context to derive insights into functionality. The reproductive tracts of 59 female cetaceans (20 species, 6 families) were dissected. Phylogenetically-controlled reduced major axis regressions were used to establish a scaling trend for the female genitalia of cetaceans. An unparalleled level of vaginal diversity within a mammalian order was found. Vaginal folds varied in number and size across species, and vaginal fold length was positively allometric with body length. Vaginal length was not a significant predictor of vaginal fold length. Functional hypotheses regarding the role of vaginal folds and the potential selection pressures that could lead to evolution of these structures are discussed. Vaginal folds may present physical barriers, which obscure the pathway of seawater and/or sperm travelling through the vagina. This study contributes broad insights to the evolution of reproductive morphology and aquatic adaptations and lays the foundation for future functional morphology analyses. PMID:28362830

  17. Stabilization of flow past a rounded cylinder

    NASA Astrophysics Data System (ADS)

    Samtaney, Ravi; Zhang, Wei

    2016-11-01

    We perform global linear stability analysis on low-Re flow past a rounded cylinder. The cylinder corners are rounded with a radius R, normalized as R+ = R / D where D is the cylinder diameter, and its effect on the flow stability characteristics is investigated. We compute the critical Reynolds number (Recr) for the onset of first instability, and quantify the perturbation growth rate for the super-critical flows. It is found that the flow can be stabilized by partially rounding the cylinder. Compared with the square and circular cylinders, the partially rounded cylinder has a higher Recr , attaining a maximum at around R+ = 0 . 30 , and the perturbation growth rate of the super-critical flows is reduced for Re <= 100 . We perform sensitivity analysis to explore the source of the stabilization. The growth rate sensitivity to base flow modification has two different spatial structures: the growth rate is sensitive to the wake backflow in a large region for square-like cylinders (R+ -> 0 . 00), while only the near-wake backflow is crucial for circular-like cylinders (R+ -> 0 . 50). The stability analysis results are also verified with those of the direct simulations and very good agreement is achieved. Supported by the KAUST Office of Competitive Research Funds under Award No. URF/1/1394-01. The supercomputer Shaheen at KAUST was utilized for the simulations.

  18. Vaginal Microbiota in Pregnancy: Evaluation Based on Vaginal Flora, Birth Outcome, and Race.

    PubMed

    Subramaniam, Akila; Kumar, Ranjit; Cliver, Suzanne P; Zhi, Degui; Szychowski, Jeff M; Abramovici, Adi; Biggio, Joseph R; Lefkowitz, Elliot J; Morrow, Casey; Edwards, Rodney K

    2016-03-01

    This study aims to evaluate vaginal microbiota differences by bacterial vaginosis (BV), birth timing, and race, and to estimate parameters to power future vaginal microbiome studies. Previously, vaginal swabs were collected at 21 to 25 weeks (stored at -80°C), and vaginal smears evaluated for BV (Nugent criteria). In a blinded fashion, 40 samples were selected, creating 8 equal-sized groups stratified by race (black/white), BV (present/absent), and birth timing (preterm/term). Samples were thawed, DNA extracted, and prepared. Polymerase chain reaction (PCR) with primers targeting the 16S rDNA V4 region was used to prepare an amplicon library. PCR products were sequenced and analyzed using quantitative insight into microbial ecology; taxonomy was assigned using ribosomal database program classifier (threshold 0.8) against the modified Greengenes database. After quality control, 97,720 sequences (mean) per sample, single-end 250 base-reads, were analyzed. BV samples had greater microbiota diversity (p < 0.05)-with BVAB1, Prevotella, and unclassified genus, Bifidobacteriaceae family (all p < 0.001) more abundant; there was minimal content of Gardnerella or Mobiluncus. Microbiota did not differ by race or birth timing, but there was an association between certain microbial clusters and preterm birth (p = 0.07). To evaluate this difference, 159 patients per group are needed. There are differences in the vaginal microbiota between patients with and without BV. Larger studies should assess the relationship between microbiota composition and preterm birth. Thieme Medical Publishers 333 Seventh Avenue, New York, NY 10001, USA.

  19. Erectile Function Durability Following Permanent Prostate Brachytherapy

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Taira, Al V.; Merrick, Gregory S., E-mail: gmerrick@urologicresearchinstitute.or; Galbreath, Robert W.

    2009-11-01

    Purpose: To evaluate long-term changes in erectile function following prostate brachytherapy. Methods and Materials: This study included 226 patients with prostate cancer and preimplant erectile function assessed by the International Index of Erectile Function-6 (IIEF-6) who underwent brachytherapy in two prospective randomized trials between February 2001 and January 2003. Median follow-up was 6.4 years. Pre- and postbrachytherapy potency was defined as IIEF-6 >= 13 without pharmacologic or mechanical support. The relationship among clinical, treatment, and dosimetric parameters and erectile function was examined. Results: The 7-year actuarial rate of potency preservation was 55.6% with median postimplant IIEF of 22 in potentmore » patients. Potent patients were statistically younger (p = 0.014), had a higher preimplant IIEF (p < 0.001), were less likely to be diabetic (p = 0.002), and were more likely to report nocturnal erections (p = 0.008). Potency preservation in men with baseline IIEF scores of 29-30, 24-28, 18-23, and 13-17 were 75.5% vs. 73.6%, 51.7% vs. 44.8%, 48.0% vs. 40.0%, and 23.5% vs. 23.5% in 2004 vs. 2008. In multivariate Cox regression analysis, preimplant IIEF, hypertension, diabetes, prostate size, and brachytherapy dose to proximal penis strongly predicted for potency preservation. Impact of proximal penile dose was most pronounced for men with IIEF of 18-23 and aged 60-69. A significant minority of men who developed postimplant impotence ultimately regained erectile function. Conclusion: Potency preservation and median IIEF scores following brachytherapy are durable. Thoughtful dose sparing of proximal penile structures and early penile rehabilitation may further improve these results.« less

  20. A comparison study on various low energy sources in interstitial prostate brachytherapy

    PubMed Central

    Bakhshabadi, Mahdi; Ghorbani, Mahdi; Knaup, Courtney; Meigooni, Ali S.

    2016-01-01

    Purpose Low energy sources are routinely used in prostate brachytherapy. 125I is one of the most commonly used sources. Low energy 131Cs source was introduced recently as a brachytherapy source. The aim of this study is to compare dose distributions of 125I, 103Pd, and 131Cs sources in interstitial brachytherapy of prostate. Material and methods ProstaSeed 125I brachytherapy source was simulated using MCNPX Monte Carlo code. Additionally, two hypothetical sources of 103Pd and 131Cs were simulated with the same geometry as the ProstaSeed 125I source, while having their specific emitted gamma spectra. These brachytherapy sources were simulated with distribution of forty-eight seeds in a phantom including prostate. The prostate was considered as a sphere with radius of 1.5 cm. Absolute and relative dose rates were obtained in various distances from the source along the transverse and longitudinal axes inside and outside the tumor. Furthermore, isodose curves were plotted around the sources. Results Analyzing the initial dose profiles for various sources indicated that with the same time duration and air kerma strength, 131Cs delivers higher dose to tumor. However, relative dose rate inside the tumor is higher and outside the tumor is lower for the 103Pd source. Conclusions The higher initial absolute dose in cGy/(h.U) of 131Cs brachytherapy source is an advantage of this source over the others. The higher relative dose inside the tumor and lower relative dose outside the tumor for the 103Pd source are advantages of this later brachytherapy source. Based on the total dose the 125I source has advantage over the others due to its longer half-life. PMID:26985200

  1. GGEMS-Brachy: GPU GEant4-based Monte Carlo simulation for brachytherapy applications

    NASA Astrophysics Data System (ADS)

    Lemaréchal, Yannick; Bert, Julien; Falconnet, Claire; Després, Philippe; Valeri, Antoine; Schick, Ulrike; Pradier, Olivier; Garcia, Marie-Paule; Boussion, Nicolas; Visvikis, Dimitris

    2015-07-01

    In brachytherapy, plans are routinely calculated using the AAPM TG43 formalism which considers the patient as a simple water object. An accurate modeling of the physical processes considering patient heterogeneity using Monte Carlo simulation (MCS) methods is currently too time-consuming and computationally demanding to be routinely used. In this work we implemented and evaluated an accurate and fast MCS on Graphics Processing Units (GPU) for brachytherapy low dose rate (LDR) applications. A previously proposed Geant4 based MCS framework implemented on GPU (GGEMS) was extended to include a hybrid GPU navigator, allowing navigation within voxelized patient specific images and analytically modeled 125I seeds used in LDR brachytherapy. In addition, dose scoring based on track length estimator including uncertainty calculations was incorporated. The implemented GGEMS-brachy platform was validated using a comparison with Geant4 simulations and reference datasets. Finally, a comparative dosimetry study based on the current clinical standard (TG43) and the proposed platform was performed on twelve prostate cancer patients undergoing LDR brachytherapy. Considering patient 3D CT volumes of 400  × 250  × 65 voxels and an average of 58 implanted seeds, the mean patient dosimetry study run time for a 2% dose uncertainty was 9.35 s (≈500 ms 10-6 simulated particles) and 2.5 s when using one and four GPUs, respectively. The performance of the proposed GGEMS-brachy platform allows envisaging the use of Monte Carlo simulation based dosimetry studies in brachytherapy compatible with clinical practice. Although the proposed platform was evaluated for prostate cancer, it is equally applicable to other LDR brachytherapy clinical applications. Future extensions will allow its application in high dose rate brachytherapy applications.

  2. Cylinder head for internal combustion engine

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Bell, D.W.

    1992-10-06

    This patent describes a cylinder head for attachment to a block assembly having at least one cylinder bore therein. It comprises: a cylinder head body adapted for attachment to the block assembly and having at least one side-entry fluid intake opening in communication with the cylinder bore, and having at least one side-exit exhaust fluid opening in communication with the cylinderbore; an intake spool mounted for axial rotation within the intake spool cavity; an exhaust spool mounted for axial rotation within the exhaust spool cavity; timing means for rotating the intake spool and the exhaust spool; and at least onemore » intake port and at least one exhaust port.« less

  3. 30 CFR 57.4601 - Oxygen cylinder storage.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... 30 Mineral Resources 1 2011-07-01 2011-07-01 false Oxygen cylinder storage. 57.4601 Section 57.4601 Mineral Resources MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR METAL AND NONMETAL... and Control Welding/cutting/compressed Gases § 57.4601 Oxygen cylinder storage. Oxygen cylinders shall...

  4. 30 CFR 57.4601 - Oxygen cylinder storage.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... 30 Mineral Resources 1 2013-07-01 2013-07-01 false Oxygen cylinder storage. 57.4601 Section 57.4601 Mineral Resources MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR METAL AND NONMETAL... and Control Welding/cutting/compressed Gases § 57.4601 Oxygen cylinder storage. Oxygen cylinders shall...

  5. 30 CFR 57.4601 - Oxygen cylinder storage.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... 30 Mineral Resources 1 2012-07-01 2012-07-01 false Oxygen cylinder storage. 57.4601 Section 57.4601 Mineral Resources MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR METAL AND NONMETAL... and Control Welding/cutting/compressed Gases § 57.4601 Oxygen cylinder storage. Oxygen cylinders shall...

  6. 30 CFR 57.4601 - Oxygen cylinder storage.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... 30 Mineral Resources 1 2014-07-01 2014-07-01 false Oxygen cylinder storage. 57.4601 Section 57.4601 Mineral Resources MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR METAL AND NONMETAL... and Control Welding/cutting/compressed Gases § 57.4601 Oxygen cylinder storage. Oxygen cylinders shall...

  7. Vaginal microbial flora analysis by next generation sequencing and microarrays; can microbes indicate vaginal origin in a forensic context?

    PubMed

    Benschop, Corina C G; Quaak, Frederike C A; Boon, Mathilde E; Sijen, Titia; Kuiper, Irene

    2012-03-01

    Forensic analysis of biological traces generally encompasses the investigation of both the person who contributed to the trace and the body site(s) from which the trace originates. For instance, for sexual assault cases, it can be beneficial to distinguish vaginal samples from skin or saliva samples. In this study, we explored the use of microbial flora to indicate vaginal origin. First, we explored the vaginal microbiome for a large set of clinical vaginal samples (n = 240) by next generation sequencing (n = 338,184 sequence reads) and found 1,619 different sequences. Next, we selected 389 candidate probes targeting genera or species and designed a microarray, with which we analysed a diverse set of samples; 43 DNA extracts from vaginal samples and 25 DNA extracts from samples from other body sites, including sites in close proximity of or in contact with the vagina. Finally, we used the microarray results and next generation sequencing dataset to assess the potential for a future approach that uses microbial markers to indicate vaginal origin. Since no candidate genera/species were found to positively identify all vaginal DNA extracts on their own, while excluding all non-vaginal DNA extracts, we deduce that a reliable statement about the cellular origin of a biological trace should be based on the detection of multiple species within various genera. Microarray analysis of a sample will then render a microbial flora pattern that is probably best analysed in a probabilistic approach.

  8. Maximal liquid bridges between horizontal cylinders

    NASA Astrophysics Data System (ADS)

    Cooray, Himantha; Huppert, Herbert E.; Neufeld, Jerome A.

    2016-08-01

    We investigate two-dimensional liquid bridges trapped between pairs of identical horizontal cylinders. The cylinders support forces owing to surface tension and hydrostatic pressure that balance the weight of the liquid. The shape of the liquid bridge is determined by analytically solving the nonlinear Laplace-Young equation. Parameters that maximize the trapping capacity (defined as the cross-sectional area of the liquid bridge) are then determined. The results show that these parameters can be approximated with simple relationships when the radius of the cylinders is small compared with the capillary length. For such small cylinders, liquid bridges with the largest cross-sectional area occur when the centre-to-centre distance between the cylinders is approximately twice the capillary length. The maximum trapping capacity for a pair of cylinders at a given separation is linearly related to the separation when it is small compared with the capillary length. The meniscus slope angle of the largest liquid bridge produced in this regime is also a linear function of the separation. We additionally derive approximate solutions for the profile of a liquid bridge, using the linearized Laplace-Young equation. These solutions analytically verify the above-mentioned relationships obtained for the maximization of the trapping capacity.

  9. American Brachytherapy Society Task Group Report: Combination of brachytherapy and external beam radiation for high-risk prostate cancer.

    PubMed

    Spratt, Daniel E; Soni, Payal D; McLaughlin, Patrick W; Merrick, Gregory S; Stock, Richard G; Blasko, John C; Zelefsky, Michael J

    To review outcomes for high-risk prostate cancer treated with combined modality radiation therapy (CMRT) utilizing external beam radiation therapy (EBRT) with a brachytherapy boost. The available literature for high-risk prostate cancer treated with combined modality radiation therapy was reviewed and summarized. At this time, the literature suggests that the majority of high-risk cancers are curable with multimodal treatment. Several large retrospective studies and three prospective randomized trials comparing CMRT to dose-escalated EBRT have demonstrated superior biochemical control with CMRT. Longer followup of the randomized trials will be required to determine if this will translate to a benefit in metastasis-free survival, disease-specific survival, and overall survival. Although greater toxicity has been associated with CMRT compared to EBRT, recent studies suggest that technological advances that allow better definition and sparing of critical adjacent structures as well as increasing experience with brachytherapy have improved implant quality and the toxicity profile of brachytherapy. The role of androgen deprivation therapy is well established in the external beam literature for high-risk disease, but there is controversy regarding the applicability of these data in the setting of dose escalation. At this time, there is not sufficient evidence for the omission of androgen deprivation therapy with dose escalation in this population. Comparisons with surgery remain limited by differences in patient selection, but the evidence would suggest better disease control with CMRT compared to surgery alone. Due to a series of technological advances, modern combination series have demonstrated unparalleled rates of disease control in the high-risk population. Given the evidence from recent randomized trials, combination therapy may become the standard of care for high-risk cancers. Copyright © 2016 American Brachytherapy Society. Published by Elsevier Inc. All

  10. The Vaginal Eukaryotic DNA Virome and Preterm Birth.

    PubMed

    Wylie, Kristine M; Wylie, Todd N; Cahill, Alison G; Macones, George A; Tuuli, Methodius G; Stout, Molly J

    2018-05-05

    Despite decades of attempts to link infectious agents to preterm birth, an exact causative microbe or community of microbes remains elusive. Culture-independent sequencing of vaginal bacterial communities demonstrates community characteristics are associated with preterm birth, although none are specific enough to apply clinically. Viruses are important components of the vaginal microbiome and have dynamic relationships with vaginal bacterial communities. We hypothesized that vaginal eukaryotic DNA viral communities (the "vaginal virome") either alone or in the context of bacterial communities are associated with preterm birth. The objective of this study was to use high-throughput sequencing to examine the vaginal eukaryotic DNA virome in a cohort of pregnant women and examine associations between vaginal community characteristics and preterm birth. This is a nested case-control study within a prospective cohort study of women with singleton pregnancies, not on supplemental progesterone, and without cervical cerclage in situ. Serial mid-vaginal swabs were obtained at routine prenatal visits. DNA was extracted, bacterial communities were characterized by 16S rRNA gene sequencing, and eukaryotic viral communities were characterized by enrichment of viral nucleic acid with the ViroCap targeted sequence capture panel followed by nucleic acid sequencing. Viral communities were analyzed according to presence/absence of viruses, diversity, dynamics over time, and association with bacterial community data obtained from the same specimens. Sixty subjects contributed 128 vaginal swabs longitudinally across pregnancy. Twenty-four patients delivered preterm. Participants were predominantly African-American (65%). Six families of eukaryotic DNA viruses were detected in the vaginal samples. At least 1 virus was detected in 80% of women. No specific virus or group of viruses was associated with preterm delivery. Higher viral richness was significantly associated with preterm

  11. The Comparison of vaginal cream of mixing yogurt, honey and clotrimazole on symptoms of vaginal candidiasis.

    PubMed

    Darvishi, Maryam; Jahdi, Fereshteh; Hamzegardeshi, Zeinab; Goodarzi, Saied; Vahedi, Mohsen

    2015-04-03

    Vulvovaginal candidiasis is known as one of the most common fungal infection among women of reproductive age and considered as an important public health problem. In recent years, due to resistance to common antifungal medication, the use of traditional medicine of anti-fungal and herbal treatment increased. Therefore the objective of this study was to determine the effects of vaginal cream, mixture of yogurt and honey and comparing it with clotrimazole vaginal cream on symptoms of Vulvovaginal candidiasis in patients. In this randomized, triple blind clinical trial of 70 non-pregnant women infected with Candidal vulvovaginitis were placed in two groups of Vaginal cream mixed of yogurt and honey recipients (N=35) and clotrimazole vaginal cream (N=35). Both groups were treated for 7 days. At the beginning of study, Clinical and laboratory signs and symptoms were registered 7 and 14 days after treatment by questionnaire, observation form and secretions culture results. Data by chi-square test, t test, McNemar tests were analyzed by SPSS version 21. Significance level of 0.05 was considered. The result of present study reveals the significant differences in symptom improvement of ' yogurt and honey, than clotrimazole group (P<0.05) and also Positive results of the first cultures (one week after treatment) in "yogurt and honey" and clotrimazole (20% versus 8.6%) and second time cultivation (14 days after treatment) (17/1% versus 8.6%) were similar and there was no significant differences between the two groups. (P>0.05) CONCLUSION: This study indicated that he therapeutic effects of vaginal cream, yogurt and honey is not only similar with clotrimazole vaginal cream but more effective in relieving some symptoms of vaginal candidiasis. Therefore, the use of this product can be suggested as an herbal remedy for candida infection treatment.

  12. The Comparison of Vaginal Cream of Mixing Yogurt, Honey and Clotrimazole on Symptoms of Vaginal Candidiasis

    PubMed Central

    Darvishi, Maryam; Jahdi, Fereshteh; Hamzegardeshi, Zeinab; Goodarzi, Saied; Vahedi, Mohsen

    2015-01-01

    Background: Vulvovaginal candidiasis is known as one of the most common fungal infection among women of reproductive age and considered as an important public health problem. In recent years, due to resistance to common antifungal medication, the use of traditional medicine of anti-fungal and herbal treatmentis increased. Therefore the objective of this study was to determine the effects of vaginal cream, mixture of yogurt and honey and comparing it with clotrimazole vaginal cream on symptoms of Vulvovaginal candidiasis in patients. Methods: In this randomized, triple blind clinical trial of 70 non-pregnant women infected with Candidalvulvovaginitis were placed in two groups of Vaginal cream mixed of yogurt and honey recipients (N = 35) and clotrimazole vaginal cream (N = 35). Both groups were treated for 7 days.At the beginning of study, Clinical and laboratory signs and symptoms were registered 7 and 14 days after treatment by questionnaire, observation formand secretions medium culture results. Data were analyzed by chi-square test, t test, McNemar tests through SPSS version 21. Significance level of 0.05 was considered. Results: The result of present study reveals the significant differences in symptom improvement of yogurt and honey, toward clotrimazole group (P < 0.05) and also Positive results of the first cultures (one week after treatment) in “yogurt and honey” and clotrimazole (20% versus 8.6%) and second time cultivation (14 days after treatment) (17.1% versus 8.6%) were similar and there was no significant differences between the two groups. (P > 0.05). Conclusion: This study indicated that the therapeutic effects of vaginal cream, yogurt and honey is not only similar with clotrimazole vaginal cream but is more effective in relieving some symptoms of vaginal candidiasis. Therefore, the use of this product can be suggested as an herbal remedy for candida infection treatment. PMID:26153168

  13. 30 CFR 56.4601 - Oxygen cylinder storage.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... 30 Mineral Resources 1 2012-07-01 2012-07-01 false Oxygen cylinder storage. 56.4601 Section 56.4601 Mineral Resources MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR METAL AND NONMETAL... Control Welding/cutting/compressed Gases § 56.4601 Oxygen cylinder storage. Oxygen cylinders shall not be...

  14. 30 CFR 56.4601 - Oxygen cylinder storage.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... 30 Mineral Resources 1 2014-07-01 2014-07-01 false Oxygen cylinder storage. 56.4601 Section 56.4601 Mineral Resources MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR METAL AND NONMETAL... Control Welding/cutting/compressed Gases § 56.4601 Oxygen cylinder storage. Oxygen cylinders shall not be...

  15. 30 CFR 56.4601 - Oxygen cylinder storage.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... 30 Mineral Resources 1 2013-07-01 2013-07-01 false Oxygen cylinder storage. 56.4601 Section 56.4601 Mineral Resources MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR METAL AND NONMETAL... Control Welding/cutting/compressed Gases § 56.4601 Oxygen cylinder storage. Oxygen cylinders shall not be...

  16. 30 CFR 56.4601 - Oxygen cylinder storage.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... 30 Mineral Resources 1 2011-07-01 2011-07-01 false Oxygen cylinder storage. 56.4601 Section 56.4601 Mineral Resources MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR METAL AND NONMETAL... Control Welding/cutting/compressed Gases § 56.4601 Oxygen cylinder storage. Oxygen cylinders shall not be...

  17. Performance profiling for brachytherapy applications

    NASA Astrophysics Data System (ADS)

    Choi, Wonqook; Cho, Kihyeon; Yeo, Insung

    2018-05-01

    In many physics applications, a significant amount of software (e.g. R, ROOT and Geant4) is developed on novel computing architectures, and much effort is expended to ensure the software is efficient in terms of central processing unit (CPU) time and memory usage. Profiling tools are used during the evaluation process to evaluate the efficiency; however, few such tools are able to accommodate low-energy physics regions. To address this limitation, we developed a low-energy physics profiling system in Geant4 to profile the CPU time and memory of software applications in brachytherapy applications. This paper describes and evaluates specific models that are applied to brachytherapy applications in Geant4, such as QGSP_BIC_LIV, QGSP_BIC_EMZ, and QGSP_BIC_EMY. The physics range in this tool allows it to be used to generate low energy profiles in brachytherapy applications. This was a limitation in previous studies, which caused us to develop a new profiling tool that supports profiling in the MeV range, in contrast to the TeV range that is supported by existing high-energy profiling tools. In order to easily compare the profiling results between low-energy and high-energy modes, we employed the same software architecture as that in the SimpliCarlo tool developed at the Fermilab National Accelerator Laboratory (FNAL) for the Large Hadron Collider (LHC). The results show that the newly developed profiling system for low-energy physics (less than MeV) complements the current profiling system used for high-energy physics (greater than TeV) applications.

  18. Laboratory diagnosis of vaginal infections.

    PubMed

    Metzger, G D

    1998-01-01

    Vaginal discomfort and/or odor are a common complaint in primary care visits by female patients. This is especially true among sexually active women of childbearing age. Because treatment varies depending upon which syndrome is present, effective treatment depends upon accurate diagnosis. The microscopic exams for diagnosing vaginal complaints are most frequently done in primary care sites. Because of this, few clinical laboratory scientists (CLSs) have the opportunity to become familiar with microscopy on this specimen type. In addition, literature on the subject is only gradually becoming available. This paper will attempt to briefly review the clinical and microscopic features of the common syndromes associated with vaginal discomfort.

  19. Analysis of the Vaginal Microbiome by Next-Generation Sequencing and Evaluation of its Performance as a Clinical Diagnostic Tool in Vaginitis

    PubMed Central

    Hong, Ki Ho; Hong, Sung Kuk; Cho, Sung Im; Ra, Eunkyung; Han, Kyung Hee; Kang, Soon Beom; Kim, Eui-Chong; Park, Sung Sup

    2016-01-01

    Background Next-generation sequencing (NGS) can detect many more microorganisms of a microbiome than traditional methods. This study aimed to analyze the vaginal microbiomes of Korean women by using NGS that included bacteria and other microorganisms. The NGS results were compared with the results of other assays, and NGS was evaluated for its feasibility for predicting vaginitis. Methods In total, 89 vaginal swab specimens were collected. Microscopic examinations of Gram staining and microbiological cultures were conducted on 67 specimens. NGS was performed with GS junior system on all of the vaginal specimens for the 16S rRNA, internal transcribed spacer (ITS), and Tvk genes to detect bacteria, fungi, and Trichomonas vaginalis. In addition, DNA probe assays of the Candida spp., Gardnerella vaginalis, and Trichomonas vaginalis were performed. Various predictors of diversity that were obtained from the NGS data were analyzed to predict vaginitis. Results ITS sequences were obtained in most of the specimens (56.2%). The compositions of the intermediate and vaginitis Nugent score groups were similar to each other but differed from the composition of the normal score group. The fraction of the Lactobacillus spp. showed the highest area under the curve value (0.8559) in ROC curve analysis. The NGS and DNA probe assay results showed good agreement (range, 86.2-89.7%). Conclusions Fungi as well as bacteria should be considered for the investigation of vaginal microbiome. The intermediate and vaginitis Nugent score groups were indistinguishable in NGS. NGS is a promising diagnostic tool of the vaginal microbiome and vaginitis, although some problems need to be resolved. PMID:27374709

  20. Failed Operative Vaginal Delivery

    PubMed Central

    Alexander, James M.; Leveno, Kenneth J.; Hauth, John C.; Landon, Mark B.; Gilbert, Sharon; Spong, Catherine Y.; Varner, Michael W.; Caritis, Steve N.; Meis, Paul; Wapner, Ronald J.; Sorokin, Yoram; Miodovnik, Menachem; O'Sullivan, Mary J.; Sibai, Baha M.; Langer, Oded; Gabbe, Steven G.

    2010-01-01

    Objective To compare maternal and neonatal outcomes in women undergoing a second stage cesarean after a trial of operative vaginal delivery with women undergoing a second stage cesarean without such an attempt. Methods This study is a secondary analysis of the women who underwent second stage cesarean. .The maternal outcomes examined included blood transfusion, endometritis, wound complication, anesthesia use, and maternal death. Infant outcomes examined included umbilical artery pH < 7.0, Apgar of 3 or less at 5 minutes, seizures within 24 hours of birth, hypoxic ischemic encephalopathy (HIE), stillbirth, skull fracture, and neonatal death. Results Of 3189 women who underwent second stage cesarean, operative vaginal delivery was attempted in 640. Labor characteristics were similar in the two groups with the exception of the admission to delivery time and cesarean indication. Those with an attempted operative vaginal delivery were more likely to undergo cesarean delivery for a non-reassuring fetal heart rate tracing (18.0% vs 13.9%, p=.01), have a wound complication (2.7% vs 1.0%; OR 2.65 95% CI 1.43–4.91), and require general anesthesia (8.0% vs 4.1%, OR 2.05 95% CI 1.44–2.91). Neonatal outcomes including umbilical artery pH less than 7.0, Apgar at or below 3 at 5 minutes, and hypoxic ischemic encephalopathy were more common for those with an attempted operative vaginal delivery. This was not significant when cases with a non-reassuring fetal heart rate tracing were removed. Conclusion Cesarean delivery after an attempt at operative vaginal delivery was not associated with adverse neonatal outcomes in the absence of a non-reassuring fetal heart rate tracing. PMID:20168101

  1. Brachytherapy of prostate cancer after colectomy for colorectal cancer: pilot experience.

    PubMed

    Koutrouvelis, Panos G; Theodorescu, Dan; Katz, Stuart; Lailas, Niko; Hendricks, Fred

    2005-01-01

    We present a method of brachytherapy for prostate cancer using a 3-dimensional stereotactic system and computerized tomography guidance in patients without a rectum due to previous treatment for colorectal cancer. From June 1994 to November 2003 a cohort of 800 patients were treated with brachytherapy for prostate cancer. Four patients had previously been treated for colorectal cancer with 4,500 cGy external beam radiation therapy, abdominoperineal resection and chemotherapy, while 1 underwent abdominoperineal resection alone for ulcerative colitis. Because of previous radiation therapy, these patients were not candidates for salvage external beam radiation therapy or radical prostatectomy and they had no rectum for transrectal ultrasound guided transperineal brachytherapy or cryotherapy. A previously described, 3-dimensional stereotactic system was used for brachytherapy in these patients. The prescribed radiation dose was 120 to 144 Gy with iodine seeds in rapid strand format. Patient followup included clinical examination and serum prostate specific antigen measurement. Average followup was 18.6 months. Four patients had excellent biochemical control, while 1 had biochemical failure. Patients did not experience any gastrointestinal morbidity. One patient had a stricture of the distal ureter, requiring a stent. Three-dimensional computerized tomography guided brachytherapy for prostate cancer in patients with a history of colorectal cancer who have no rectum is a feasible method of treatment.

  2. 46 CFR 197.338 - Compressed gas cylinders.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... STANDARDS GENERAL PROVISIONS Commercial Diving Operations Equipment § 197.338 Compressed gas cylinders. Each compressed gas cylinder must— (a) Be stored in a ventilated area; (b) Be protected from excessive heat; (c... 46 Shipping 7 2010-10-01 2010-10-01 false Compressed gas cylinders. 197.338 Section 197.338...

  3. Low-dose-rate or high-dose-rate brachytherapy in treatment of prostate cancer – between options

    PubMed Central

    2013-01-01

    Purpose Permanent low-dose-rate (LDR-BT) and temporary high-dose-rate (HDR-BT) brachytherapy are competitive techniques for clinically localized prostate radiotherapy. Although a randomized trial will likely never to be conducted comparing these two forms of brachytherapy, a comparative analysis proves useful in understanding some of their intrinsic differences, several of which could be exploited to improve outcomes. The aim of this paper is to look for possible similarities and differences between both brachytherapy modalities. Indications and contraindications for monotherapy and for brachytherapy as a boost to external beam radiation therapy (EBRT) are presented. It is suggested that each of these techniques has attributes that advocates for one or the other. First, they represent the extreme ends of the spectrum with respect to dose rate and fractionation, and therefore have inherently different radiobiological properties. Low-dose-rate brachytherapy has the great advantage of being practically a one-time procedure, and enjoys a long-term follow-up database supporting its excellent outcomes and low morbidity. Low-dose-rate brachytherapy has been a gold standard for prostate brachytherapy in low risk patients since many years. On the other hand, HDR is a fairly invasive procedure requiring several sessions associated with a brief hospital stay. Although lacking in significant long-term data, it possesses the technical advantage of control over its postimplant dosimetry (by modulating the source dwell time and position), which is absent in LDR brachytherapy. This important difference in dosimetric control allows HDR doses to be escalated safely, a flexibility that does not exist for LDR brachytherapy. Conclusions Radiobiological models support the current clinical evidence for equivalent outcomes in localized prostate cancer with either LDR or HDR brachytherapy, using current dose regimens. At present, all available clinical data regarding these two techniques

  4. Unraveling the Dynamics of the Human Vaginal Microbiome.

    PubMed

    Nunn, Kenetta L; Forney, Larry J

    2016-09-01

    Four Lactobacillus species, namely L. crispatus , L. iners , L. gasseri , and L. jensenii , commonly dominate the vaginal communities of most reproductive-age women. It is unclear why these particular species, and not others, are so prevalent. Historically, estrogen-induced glycogen production by the vaginal epithelium has been proffered as being key to supporting the proliferation of vaginal lactobacilli. However, the 'fly in the ointment' (that has been largely ignored) is that the species of Lactobacillus commonly found in the human vagina cannot directly metabolize glycogen. It would appear that this riddle has been solved as studies have demonstrated that vaginal lactobacilli can metabolize the products of glycogen depolymerization by α-amylase, and fortunately, amylase activity is found in vaginal secretions. These amylases are presumed to be host-derived, but we suggest that other bacterial populations in vaginal communities could also be sources of amylase in addition to (or instead of) the host. Here we briefly review what is known about human vaginal bacterial communities and discuss how glycogen-derived resources and resource competition might shape the composition and structure of these communities.

  5. Penile brachytherapy: Results for 49 patients

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Crook, Juanita M.; Jezioranski, John; Grimard, Laval

    2005-06-01

    Purpose: To report results for 49 men with squamous cell carcinoma (SCC) of the penis treated with primary penile interstitial brachytherapy at one of two institutions: the Ottawa Regional Cancer Center, Ottawa, and the Princess Margaret Hospital, Toronto, Ontario, Canada. Methods and Materials: From September 1989 to September 2003, 49 men (mean age, 58 years; range, 22-93 years) had brachytherapy for penile SCC. Fifty-one percent of tumors were T1, 33% T2, and 8% T3; 4% were in situ and 4% Tx. Grade was well differentiated in 31%, moderate in 45%, and poor in 2%; grade was unspecified for 20%. Onemore » tumor was verrucous. All tumors in Toronto had pulsed dose rate (PDR) brachytherapy (n = 23), whereas those in Ottawa had either Iridium wire (n 22) or seeds (n = 4). Four patients had a single plane implant with a plastic tube technique, and all others had a volume implant with predrilled acrylic templates and two or three parallel planes of needles (median, six needles). Mean needle spacing was 13.5 mm (range, 10-18 mm), mean dose rate was 65 cGy/h (range, 33-160 cGy/h), and mean duration was 98.8 h (range, 36-188 h). Dose rates for PDR brachytherapy were 50-61.2 cGy/h, with no correction in total dose, which was 60 Gy in all cases. Results: Median follow-up was 33.4 months (range, 4-140 months). At 5 years, actuarial overall survival was 78.3% and cause-specific survival 90.0%. Four men died of penile cancer, and 6 died of other causes with no evidence of recurrence. The cumulative incidence rate for never having experienced any type of failure at 5 years was 64.4% and for local failure was 85.3%. All 5 patients with local failure were successfully salvaged by surgery; 2 other men required penectomy for necrosis. The soft tissue necrosis rate was 16% and the urethral stenosis rate 12%. Of 8 men with regional failure, 5 were salvaged by lymph node dissection with or without external radiation. All 4 men with distant failure died of disease. Of 49 men, 42 had

  6. Vision-guided gripping of a cylinder

    NASA Technical Reports Server (NTRS)

    Nicewarner, Keith E.; Kelley, Robert B.

    1991-01-01

    The motivation for vision-guided servoing is taken from tasks in automated or telerobotic space assembly and construction. Vision-guided servoing requires the ability to perform rapid pose estimates and provide predictive feature tracking. Monocular information from a gripper-mounted camera is used to servo the gripper to grasp a cylinder. The procedure is divided into recognition and servo phases. The recognition stage verifies the presence of a cylinder in the camera field of view. Then an initial pose estimate is computed and uncluttered scan regions are selected. The servo phase processes only the selected scan regions of the image. Given the knowledge, from the recognition phase, that there is a cylinder in the image and knowing the radius of the cylinder, 4 of the 6 pose parameters can be estimated with minimal computation. The relative motion of the cylinder is obtained by using the current pose and prior pose estimates. The motion information is then used to generate a predictive feature-based trajectory for the path of the gripper.

  7. Long-term outcomes in younger men following permanent prostate brachytherapy.

    PubMed

    Shapiro, Edan Y; Rais-Bahrami, Soroush; Morgenstern, Carol; Napolitano, Barbara; Richstone, Lee; Potters, Louis

    2009-04-01

    We reviewed the long-term outcomes in men undergoing permanent prostate brachytherapy with a focus on those presenting before age 60 years. Between 1992 and 2005 a total of 2,119 patients with clinical stage T1-T2, N0, M0 prostate cancer treated with permanent prostate brachytherapy were included in this study. Treatment regimens consisted of permanent prostate brachytherapy with or without hormone therapy, permanent prostate brachytherapy with external beam radiotherapy, or all 3 modalities. Biochemical recurrence was defined using the Phoenix definition. Multivariate analysis was performed to determine if age and/or other clinicopathological features were associated with disease progression. The Kaplan-Meier method was used to calculate rates of freedom from progression with the log rank test to compare patients younger than 60 vs 60 years or older. Median followup was 56.1 months. In the study population 237 patients were younger than 60 years at diagnosis (11%). The 5 and 10-year freedom from progression rates were 90.1% and 85.6%, respectively, for the entire population. Multivariate analysis demonstrated that prostate specific antigen (p <0.01), biopsy Gleason score (p <0.0001) and year of treatment (p <0.001) were associated with freedom from progression while age (p = 0.95) and clinical stage (p = 0.11) were not. There was no significant difference in freedom from progression between men younger than 60, or 60 years or older (log rank p = 0.46). In the younger cohort the 10-year freedom from progression for patients presenting with low, intermediate and high risk disease was 91.3%, 80.0% and 70.2% compared to 91.8%, 83.4% and 72.1%, respectively, for men 60 years or older. Our long-term results confirm favorable outcomes after permanent prostate brachytherapy in men younger than 60 years. Outcomes are impacted by disease related risk factors but not by age or clinical stage. Definitive treatment options for younger men with clinically localized prostate

  8. Vaginal bleeding

    MedlinePlus

    ... who are approaching menopause. Women who take oral contraceptives may experience episodes of abnormal vaginal bleeding. Often ... Practice Bulletin No. 110: noncontraceptive uses of hormonal contraceptives. Obstet Gynecol . 2010;115(1):206-218. PMID: ...

  9. Vaginal Discharge

    MedlinePlus

    ... also be on the lookout for symptoms of yeast infections, bacterial vaginosis and trichomoniasis, 3 infections that ... cause changes in your vaginal discharge. Signs of yeast infections White, cottage cheese-like discharge Swelling and ...

  10. Effect of Vaginal Hygiene Module to Attitudes and Behavior of Pathological Vaginal Discharge Prevention Among Female Adolescents in Slemanregency, Yogyakarta, Indonesia

    PubMed Central

    Sumarah, Sumarah; Widyasih, Hesty

    2017-01-01

    Objective: To determine the effect of vaginal hygiene module to attitudes and behavior of pathological vaginal discharge prevention in adolescent girls in Sleman Regency, Yogyakarta, Indonesia. Materials and methods: This present study is a quasi experiment with pretest and post-test control group design. A total of 80 female students was selected randomly from two secondary schools at the study site and then distributed equally to control and experimental group. Only participants in the experimental group were given self-learning vaginal hygiene module to maintain vaginal cleanliness. A questionnaire was used as an instrument to measure the attitudes and behavior of vaginal discharge prevention. Paired and independent sample t-tests with significance level (p value) at 0.05 and Confidence Interval (CI) of 95%were employed to compare the mean difference. Results: There is a significant difference in the students’ attitude and practice of pathological vaginal discharge prevention between intervention and control group. The students who have been exposed to vaginal hygiene module for six months showed better attitudes and practice in pathological vaginal discharge prevention compared to their counterpart in control group who do not receive any module. Conclusion: The present study implied that vaginal hygiene module can be provided widely for female adolescents at their early puberty. District health officers may work closely with schools’ health promoter to reach the students and create a supportive environment for reproductive health discussion and forum in order to achieve better adolescents’ reproductive health status. PMID:29282418

  11. Measurements of the Flowfield Interaction Between Tandem Cylinders

    NASA Technical Reports Server (NTRS)

    Neuhart, Dan H.; Jenkins, Luther N.; Choudhari, Meelan M.; Khorrami, Mehdi R.

    2009-01-01

    This paper presents the most recent measurements from an ongoing investigation of the unsteady wake interference between a pair of circular cylinders in tandem. The purpose of this investigation is to help build an in-depth experimental database for this canonical flow configuration that embodies the effects of component interaction in landing gear noise. This new set of measurements augments the previous database at the primary Reynolds number (based on tunnel speed and cylinder diameter) of 1.66 105 in four important respects. First, better circumferential resolution of surface pressure fluctuations is obtained via cylinder "clocking". Second, higher resolution particle image velocimetry measurements of the shear layer separating from the cylinders are achieved. Third, the effects of simultaneous boundary layer trips along both the front and rear cylinders, versus front cylinder alone in the previous measurements, are studied. Lastly, on-surface and off-surface characteristics of unsteady flow near the "critical" cylinder spacing, wherein the flow switches intermittently between two states that are characteristic of lower and higher spacings, are examined. This critical spacing occurs in the middle of a relatively sudden change in the drag of either cylinder and is characterized by a loud intermittent noise and a flow behavior that randomly transitions between shear layer attachment to the rear cylinder and constant shedding and rollup in front of it. Analysis of this bistable flow state reveals much larger spanwise correlation lengths of surface pressure fluctuations than those at larger and smaller values of the cylinder spacing.

  12. Atrophic Vaginitis in Breast Cancer Survivors: A Difficult Survivorship Issue

    PubMed Central

    Lester, Joanne; Pahouja, Gaurav; Andersen, Barbara; Lustberg, Maryam

    2015-01-01

    Management of breast cancer includes systematic therapies including chemotherapy and endocrine therapy can lead to a variety of symptoms that can impair the quality of life of many breast cancer survivors. Atrophic vaginitis, caused by decreased levels of circulating estrogen to urinary and vaginal receptors, is commonly experienced by this group. Chemotherapy induced ovarian failure and endocrine therapies including aromatase inhibitors and selective estrogen receptor modulators can trigger the onset of atrophic vaginitis or exacerbate existing symptoms. Symptoms of atrophic vaginitis include vaginal dryness, dyspareunia, and irritation of genital skin, pruritus, burning, vaginal discharge, and soreness. The diagnosis of atrophic vaginitis is confirmed through patient-reported symptoms and gynecological examination of external structures, introitus, and vaginal mucosa. Lifestyle modifications can be helpful but are usually insufficient to significantly improve symptoms. Non-hormonal vaginal therapies may provide additional relief by increasing vaginal moisture and fluid. Systemic estrogen therapy is contraindicated in breast cancer survivors. Continued investigations of various treatments for atrophic vaginitis are necessary. Local estrogen-based therapies, DHEA, testosterone, and pH-balanced gels continue to be evaluated in ongoing studies. Definitive results are needed pertaining to the safety of topical estrogens in breast cancer survivors. PMID:25815692

  13. Atrophic vaginitis in breast cancer survivors: a difficult survivorship issue.

    PubMed

    Lester, Joanne; Pahouja, Gaurav; Andersen, Barbara; Lustberg, Maryam

    2015-03-25

    Management of breast cancer includes systematic therapies including chemotherapy and endocrine therapy can lead to a variety of symptoms that can impair the quality of life of many breast cancer survivors. Atrophic vaginitis, caused by decreased levels of circulating estrogen to urinary and vaginal receptors, is commonly experienced by this group. Chemotherapy induced ovarian failure and endocrine therapies including aromatase inhibitors and selective estrogen receptor modulators can trigger the onset of atrophic vaginitis or exacerbate existing symptoms. Symptoms of atrophic vaginitis include vaginal dryness, dyspareunia, and irritation of genital skin, pruritus, burning, vaginal discharge, and soreness. The diagnosis of atrophic vaginitis is confirmed through patient-reported symptoms and gynecological examination of external structures, introitus, and vaginal mucosa. Lifestyle modifications can be helpful but are usually insufficient to significantly improve symptoms. Non-hormonal vaginal therapies may provide additional relief by increasing vaginal moisture and fluid. Systemic estrogen therapy is contraindicated in breast cancer survivors. Continued investigations of various treatments for atrophic vaginitis are necessary. Local estrogen-based therapies, DHEA, testosterone, and pH-balanced gels continue to be evaluated in ongoing studies. Definitive results are needed pertaining to the safety of topical estrogens in breast cancer survivors.

  14. The perioperative charge equivalence of interstitial brachytherapy and radical prostatectomy with 1-year followup.

    PubMed

    Kohan, A D; Armenakas, N A; Fracchia, J A

    2000-02-01

    We compare the comprehensive 1-year charges in a consecutive group of patients undergoing radical prostatectomy and transperineal interstitial brachytherapy for clinically localized prostate cancer at a single urban institution. A total of 60 consecutive men with clinically localized prostate cancer (T1-T2, N0, M0) were treated during a 15-month period with radical prostatectomy or interstitial brachytherapy. Hospital and outpatient records were analyzed for each patient in regard to preoperative, operative and postoperative charges. Parameters included number of encounters, diagnostic and therapeutic interventions, hospitalization and operative charges, and followup visits, diagnostic tests and interventions for 1 year. All charge calculations were based arbitrarily on the 1996 Medicare fee schedule, factoring in the mandated global charge reimbursement period of 90 days for both procedures. Of the patients 38 underwent radical prostatectomy (prostatectomy group) and 22 underwent interstitial brachytherapy (brachytherapy group). The brachytherapy group was older with higher pretreatment serum prostate specific antigen and clinical stage disease, and more frequently received neoadjuvant hormonal therapy compared to the prostatectomy group. The 2 groups were similar in Gleason score and, when applicable, duration of neoadjuvant hormonal therapy. Preoperative charges were 15.3% lower for prostatectomy than for brachytherapy (not statistically significant). Conversely, operative charges for prostatectomy were 13.5% higher (p = 0.04). The major difference among preoperative, operative and postoperative charges was for those incurred postoperatively by the brachytherapy group, which were 56.0% higher than those for the prostatectomy group ($2,285.20 versus $1,007.20, p = 0.0004). Transperineal interstitial seed implantation is perceived by many as more cost-effective than radical prostatectomy for patients with clinically localized prostate cancer. We demonstrated that

  15. Design and optimization of a brachytherapy robot

    NASA Astrophysics Data System (ADS)

    Meltsner, Michael A.

    Trans-rectal ultrasound guided (TRUS) low dose rate (LDR) interstitial brachytherapy has become a popular procedure for the treatment of prostate cancer, the most common type of non-skin cancer among men. The current TRUS technique of LDR implantation may result in less than ideal coverage of the tumor with increased risk of negative response such as rectal toxicity and urinary retention. This technique is limited by the skill of the physician performing the implant, the accuracy of needle localization, and the inherent weaknesses of the procedure itself. The treatment may require 100 or more sources and 25 needles, compounding the inaccuracy of the needle localization procedure. A robot designed for prostate brachytherapy may increase the accuracy of needle placement while minimizing the effect of physician technique in the TRUS procedure. Furthermore, a robot may improve associated toxicities by utilizing angled insertions and freeing implantations from constraints applied by the 0.5 cm-spaced template used in the TRUS method. Within our group, Lin et al. have designed a new type of LDR source. The "directional" source is a seed designed to be partially shielded. Thus, a directional, or anisotropic, source does not emit radiation in all directions. The source can be oriented to irradiate cancerous tissues while sparing normal ones. This type of source necessitates a new, highly accurate method for localization in 6 degrees of freedom. A robot is the best way to accomplish this task accurately. The following presentation of work describes the invention and optimization of a new prostate brachytherapy robot that fulfills these goals. Furthermore, some research has been dedicated to the use of the robot to perform needle insertion tasks (brachytherapy, biopsy, RF ablation, etc.) in nearly any other soft tissue in the body. This can be accomplished with the robot combined with automatic, magnetic tracking.

  16. Comparison of aerodynamic noise from three nose-cylinder combinations

    NASA Technical Reports Server (NTRS)

    Guenther, R. A.; Reding, M. P.

    1970-01-01

    Results of experiments with three different cylinder and blunted nose combinations are discussed. Combinations include smooth cylinder with single 15 deg cone, smooth cylinder with double cone of 25 and 10 deg, and longitudinally corrugated cylinder with similar double cone.

  17. Effect of vaginal estrogen on pessary use

    PubMed Central

    Dessie, Sybil G.; Armstrong, Katherine; Modest, Anna M.; Hacker, Michele R.

    2016-01-01

    Introduction and hypothesis Many providers recommend concurrent estrogen therapy with pessary use to limit complications; however, limited data exist to support this practice. We hypothesized that vaginal estrogen supplementation decreases incidence of pessary-related complications and discontinuation. Methods We performed a retrospective cohort study of women who underwent a pessary fitting from 1 January 2007 through 1 September 2013 at one institution; participants were identified by billing code and were eligible if they were post-menopausal and had at least 3 months of pessary use and 6 months of follow-up. All tests were two sided, and P values < 0.05 were considered statistically significant. Results Data from 199 women were included; 134 used vaginal estrogen and 65 did not. Women who used vaginal estrogen had a longer median follow-up time (29.5 months) compared with women who did not (15.4 months) and were more likely to have at least one pessary check (98.5 % vs 86.2 %, P < 0.001). Those in the estrogen group were less likely to discontinue using their pessary (30.6 % vs 58.5 %, P < 0.001) and less likely to develop increased vaginal discharge than women who did not [hazard ratio (HR) 0.31, 95 % confidence interval (CI) 0.17–0.58]. Vaginal estrogen was not protective against erosions (HR 0.93, 95 % CI 0.54–1.6) or vaginal bleeding (HR 0.78, 95 % CI 0.36–1.7). Conclusions Women who used vaginal estrogen exhibited a higher incidence of continued pessary use and lower incidence of increased vaginal discharge than women who did not. PMID:26992727

  18. 21 CFR 884.5900 - Therapeutic vaginal douche apparatus.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... 21 Food and Drugs 8 2013-04-01 2013-04-01 false Therapeutic vaginal douche apparatus. 884.5900... (CONTINUED) MEDICAL DEVICES OBSTETRICAL AND GYNECOLOGICAL DEVICES Obstetrical and Gynecological Therapeutic Devices § 884.5900 Therapeutic vaginal douche apparatus. (a) Identification. A therapeutic vaginal douche...

  19. 21 CFR 884.5900 - Therapeutic vaginal douche apparatus.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... 21 Food and Drugs 8 2014-04-01 2014-04-01 false Therapeutic vaginal douche apparatus. 884.5900... (CONTINUED) MEDICAL DEVICES OBSTETRICAL AND GYNECOLOGICAL DEVICES Obstetrical and Gynecological Therapeutic Devices § 884.5900 Therapeutic vaginal douche apparatus. (a) Identification. A therapeutic vaginal douche...

  20. 21 CFR 884.5900 - Therapeutic vaginal douche apparatus.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... 21 Food and Drugs 8 2012-04-01 2012-04-01 false Therapeutic vaginal douche apparatus. 884.5900... (CONTINUED) MEDICAL DEVICES OBSTETRICAL AND GYNECOLOGICAL DEVICES Obstetrical and Gynecological Therapeutic Devices § 884.5900 Therapeutic vaginal douche apparatus. (a) Identification. A therapeutic vaginal douche...

  1. Whitmore, Henschke, and Hilaris: The reorientation of prostate brachytherapy (1970-1987).

    PubMed

    Aronowitz, Jesse N

    2012-01-01

    Urologists had performed prostate brachytherapy for decades before New York's Memorial Hospital retropubic program. This paper explores the contribution of Willet Whitmore, Ulrich Henschke, Basil Hilaris, and Memorial's physicists to the evolution of the procedure. Literature review and interviews with program participants. More than 1000 retropubic implants were performed at Memorial between 1970 and 1987. Unlike previous efforts, Memorial's program benefited from the participation of three disciplines in its conception and execution. Memorial's retropubic program was a collaboration of urologists, radiation therapists, and physicists. Their approach focused greater attention on dosimetry and radiation safety, and served as a template for subsequent prostate brachytherapy programs. Copyright © 2012 American Brachytherapy Society. Published by Elsevier Inc. All rights reserved.

  2. [Sulphurous vaginal douching and vulvovaginal atrophy].

    PubMed

    Costantino, M; Conti, V; Marongiu, M B; Napolano, G; Filippelli, A

    2017-01-01

    During climacteric the reduction or interruption of estrogenic stimulus determines a gradual atrophy of the tissues of the urogenital tract.Vulvovaginal atrophy can be cause of dryness, itch, burning, and dyspareunia. Vulvovaginal atrophy is associated also with depression. Hence the importance of an appropriate treatment of the vulvovaginal atrophy. Between therapeutic options we can add, particularly for women who suffer only from vaginal symptoms, the spa therapy that uses mineral waters with benefic effects on vaginal tissue wellness and health. On the basis of considerations described above and on the insufficient literature data, the objective of our single-arm pilot study has been to evaluate, in women suffering from vulvovaginal atrophy, the effects and safety of a vaginal douching cycle with sulphurous mineral water and impact on depression disorder frequently observed. The study was conducted on 24 women affected by vulvovaginal atrophy; mean age:57±11 years; age range:42-81 years. The subjects were treated, for 2 weeks, with sulphurous vaginal douching from Terme of Telese S.p.A. (Benevento-Italy). At the beginning and at the end of the SPA treatment the following symptoms were evaluated: dryness, burning, itch, dyspareunia and leucorrhoea (using VAS scale); the impact on psychological distress (using S.D.S. Zung-test). At the end of the spa treatment, the mean values±SD, compared to baseline, have showed a significant (p<0.05) reduction in leucorrhoea (-88%), in vulvar itch (-79%), in vaginal burning (-71%), in vaginal dryness (-65%) with an improvement of psichological distress as demonstrated by S.D.S. Zung-test. The data of this single-arm pilot clinical trial show that the sulphurous vaginal douching cycle can be considered very useful in women suffering from vulvovaginal atrophy with improving of the quality of life and social relationship.

  3. Parturition pit: the bony imprint of vaginal birth.

    PubMed

    McArthur, Tatum A; Meyer, Isuzu; Jackson, Bradford; Pitt, Michael J; Larrison, Matthew C

    2016-09-01

    To retrospectively evaluate for pits along the dorsum of the pubic body in females and compare the presence/absence of these pits to vaginal birth data. We retrospectively reviewed females with vaginal birth data who underwent pelvic CT. The presence of pits along the dorsum of the pubic body, pit grade (0 = not present; 1 = faintly imperceptible; 2 = present; 3 = prominent), and the presence of osteitis condensans ilii, preauricular sulcus, and sacroiliac joint vacuum phenomenon were assessed on imaging. Musculoskeletal radiologists who were blinded to the birth data evaluated the CTs. 48 males were also evaluated for the presence of pits. 482 female patients underwent CT pelvis and 171 were excluded due to lack of vaginal birth data. Of the 311 study patients, 262 had prior vaginal birth(s) and 194 had pits on CT. Only 7 of the 49 patients without prior vaginal birth had pits. There was a statistically significant association between vaginal birth and presence of pits (p < 0.0001). Patients with more prominent pits (grades 2/3) had a greater number of vaginal births. As vaginal deliveries increased, the odds of having parturition pits greatly increased, adjusting for age and race at CT (p < 0.0001). No males had pits. Our study indicates that parturition pits are associated with prior vaginal birth and should be considered a characteristic of the female pelvis. The lytic appearance of prominent pits on imaging can simulate disease and create a diagnostic dilemma for interpreting radiologists.

  4. Parturition Pit: The Bony Imprint of Vaginal Birth

    PubMed Central

    Meyer, Isuzu; Jackson, Bradford; Pitt, Michael J.; Larrison, Matthew C.

    2017-01-01

    Purpose To retrospectively evaluate for pits along the dorsum of the pubic body in females and compare the presence/absence of these pits to vaginal birth data. Materials and Methods We retrospectively reviewed females with vaginal birth data who underwent pelvic CT. The presence of pits along the dorsum of the pubic body, pit grade (0 = not present; 1 = faintly imperceptible; 2 = present; 3 = prominent), and the presence of osteitis condensans ilii, preauricular sulcus, and sacroiliac joint vacuum phenomenon were assessed on imaging. Musculoskeletal radiologists who were blinded to the birth data evaluated the CTs. 48 males were also evaluated for the presence of pits. Results 482 female patients underwent CT pelvis and 171 were excluded due to lack of vaginal birth data. Of the 311 study patients, 262 had prior vaginal birth(s) and 194 had pits on CT. Only 7 of the 49 patients without prior vaginal birth had pits. There was a statistically significant association between vaginal birth and presence of pits (p<0.0001). Patients with more prominent pits (grades 2/3) had a greater number of vaginal births. As vaginal deliveries increased, the odds of having parturition pits greatly increased, adjusting for age and race at CT (p<0.0001). No males had pits. Conclusion Our study indicates that parturition pits are associated prior vaginal birth and should be considered a characteristic of the female pelvis. The lytic appearance of prominent pits on imaging can simulate disease and create a diagnostic dilemma for interpreting radiologists. PMID:27270921

  5. Estrogen Vaginal

    MedlinePlus

    ... estradiol vaginal ring is also used to treat hot flushes ('hot flashes'; sudden strong feelings of heat and sweating) ... leave the ring in place when you have sex. If you choose to remove it or if ...

  6. The Performance of the Vaginal Discharge Syndromic Management in Treating Vaginal and Cervical Infection: A Systematic Review and Meta-Analysis

    PubMed Central

    Kiarie, James; Seuc, Armando; Mogasale, Vittal; Latif, Ahmed; Broutet, Nathalie

    2016-01-01

    Background This review aimed to synthesize and analyze the diagnostic accuracy and the likelihood of providing correct treatment of the syndromic approach Vaginal Discharge Flowchart in managing cervical infections caused by Neisseria gonorrhoeae (NG) and Chlamydia trachomatis (CT), and vaginal infections caused by Trichomonas vaginalis (TV) and Bacterial vaginosis (BV) and Candida albicans. This review will inform updating the WHO 2003 guidelines on Vaginal Discharge syndromic case management. Methods A systematic review was conducted on published studies from 01-01-2000 to 30-03-2015 in multiple databases. Studies evaluating the diagnostic accuracy and validation of the WHO Vaginal Discharge Flowchart were included. Validation parameters including sensitivity, specificity, positive predictive value (PPV) and negative predictive value (NPV) and the 95% confidence intervals for the different types of the flowchart were taken as outcomes, re-calculated, and analysed using a fixed model meta-analysis for data pooling. The level of agreement between the index and reference test were determined by the Cohen’s Kappa co-efficiency test. Each individual study was assessed on quality using the QUADAS-2 tool. Findings The search yielded 2,845 studies of which 16 met the eligibility criteria for final analysis. The diagnostic performance to identify cervical infections was low and resulted in a high proportion of over and missed treatment. The four flowcharts had a sensitivity between 27.37% in history and risk assessment and 90.13% with microscopy, with the inverse in specificity rates. The treatment performances between the flowcharts were inconsistent. The same applies to the use of vaginal discharge flowchart for treating vaginal infections. For vaginal infections the vaginal discharge flowchart had a good performance in flowchart 3 with 91.68% of sensitivity; 99.97% specificity; 99.93% PPV and 0.02% who missed their treatment and 8.32% of women who were over treated

  7. Vulvovaginitis and vaginal discharge in general practice

    PubMed Central

    Shannon, W.

    1975-01-01

    Ninety-four patients with vulvovaginitis and vaginal discharge were assessed clinically and had vaginal swabs taken in an effort to establish a definite diagnosis. A high incidence of fungous infection was found while there was a surprisingly low incidence of Trichomonal vaginitis. These findings vary markedly from recent surveys in other countries (Delaha et al. (1964); Gray and Barnes, 1965; Desai et al., 1966). PMID:1223281

  8. Evaluation and implementation of triple‐channel radiochromic film dosimetry in brachytherapy

    PubMed Central

    Bradley, David; Nisbet, Andrew

    2014-01-01

    The measurement of dose distributions in clinical brachytherapy, for the purpose of quality control, commissioning or dosimetric audit, is challenging and requires development. Radiochromic film dosimetry with a commercial flatbed scanner may be suitable, but careful methodologies are required to control various sources of uncertainty. Triple‐channel dosimetry has recently been utilized in external beam radiotherapy to improve the accuracy of film dosimetry, but its use in brachytherapy, with characteristic high maximum doses, steep dose gradients, and small scales, has been less well researched. We investigate the use of advanced film dosimetry techniques for brachytherapy dosimetry, evaluating uncertainties and assessing the mitigation afforded by triple‐channel dosimetry. We present results on postirradiation film darkening, lateral scanner effect, film surface perturbation, film active layer thickness, film curling, and examples of the measurement of clinical brachytherapy dose distributions. The lateral scanner effect in brachytherapy film dosimetry can be very significant, up to 23% dose increase at 14 Gy, at ± 9 cm lateral from the scanner axis for simple single‐channel dosimetry. Triple‐channel dosimetry mitigates the effect, but still limits the useable width of a typical scanner to less than 8 cm at high dose levels to give dose uncertainty to within 1%. Triple‐channel dosimetry separates dose and dose‐independent signal components, and effectively removes disturbances caused by film thickness variation and surface perturbations in the examples considered in this work. The use of reference dose films scanned simultaneously with brachytherapy test films is recommended to account for scanner variations from calibration conditions. Postirradiation darkening, which is a continual logarithmic function with time, must be taken into account between the reference and test films. Finally, films must be flat when scanned to avoid the Callier

  9. Dragging a floating horizontal cylinder

    NASA Astrophysics Data System (ADS)

    Lee, Duck-Gyu; Kim, Ho-Young

    2010-11-01

    A cylinder immersed in a fluid stream experiences a drag, and it is well known that the drag coefficient is a function of the Reynolds number only. Here we study the force exerted on a long horizontal cylinder that is dragged perpendicular to its axis while floating on an air-water interface with a high Reynolds number. In addition to the flow-induced drag, the floating body is subjected to capillary forces along the contact line where the three phases of liquid/solid/gas meet. We first theoretically predict the meniscus profile around the horizontally moving cylinder assuming the potential flow, and show that the profile is in good agreement with that obtained experimentally. Then we compare our theoretical predictions and experimental measurement results for the drag coefficient of a floating horizontal cylinder that is given by a function of the Weber number and the Bond number. This study can help us to understand the horizontal motion of partially submerged objects at air-liquid interface, such as semi-aquatic insects and marine plants.

  10. Vaginal pH: Home-Use Tests

    MedlinePlus

    ... streptococcus. How accurate is this test? Home vaginal pH tests showed good agreement with a doctor's diagnosis. However, ... to your doctor’s test? Yes. The home vaginal pH tests are practically identical to the ones sold to ...

  11. Ovine multiparity is associated with diminished vaginal muscularis, increased elastic fibres and vaginal wall weakness: implication for pelvic organ prolapse

    PubMed Central

    Emmerson, Stuart; Young, Natharnia; Rosamilia, Anna; Parkinson, Luke; Edwards, Sharon L.; Vashi, Aditya V.; Davies-Tuck, Miranda; White, Jacinta; Elgass, Kirstin; Lo, Camden; Arkwright, John; Werkmeister, Jerome A.; Gargett, Caroline E.

    2017-01-01

    Pelvic Organ Prolapse (POP) is a major clinical burden affecting 25% of women, with vaginal delivery a major contributing factor. We hypothesised that increasing parity weakens the vagina by altering the extracellular matrix proteins and smooth muscle thereby leading to POP vulnerability. We used a modified POP-quantification (POP-Q) system and a novel pressure sensor to measure vaginal wall weakness in nulliparous, primiparous and multiparous ewes. These measurements were correlated with histological, biochemical and biomechanical properties of the ovine vagina. Primiparous and multiparous ewes had greater displacement of vaginal tissue compared to nulliparous at points Aa, Ap and Ba and lower pressure sensor measurements at points equivalent to Ap and Ba. Vaginal wall muscularis of multiparous ewes was thinner than nulliparous and had greater elastic fibre content. Collagen content was lower in primiparous than nulliparous ewes, but collagen organisation did not differ. Biomechanically, multiparous vaginal tissue was weaker and less stiff than nulliparous. Parity had a significant impact on the structure and function of the ovine vaginal wall, as the multiparous vaginal wall was weaker and had a thinner muscularis than nulliparous ewes. This correlated with “POP-Q” and pressure sensor measurements showing greater tissue laxity in multiparous compared to nulliparous ewes. PMID:28374826

  12. Vaginal flora alterations and clinical symptoms in low-risk pregnant women.

    PubMed

    Gondo, Fausto; da Silva, Márcia G; Polettini, Jossimara; Tristao, Andréa da R; Peracoli, José C; Witkin, Steven S; Rudge, Marilza V C

    2011-01-01

    To evaluate associations between alterations in vaginal flora and clinical symptoms in low-risk pregnant women. Vaginal specimens from 245 pregnant women were analyzed by microscopy for vaginal flora. Signs and symptoms of vaginal infection were determined by patient interviews and gynecologic examinations. Abnormal vaginal flora was identified in 45.7% of the subjects. The final clinical diagnoses were bacterial vaginosis (21.6%), vaginal candidosis (10.2%), intermediate vaginal flora (5.2%), aerobic vaginitis (2.9%), mixed flora (2.9%) and other abnormal findings (2.9%). The percentage of women with or without clinical signs or symptoms was not significantly different between these categories. The presence of vaginal odor or vaginal discharge characteristics was not diagnostic of any specific flora alteration; pruritus was highly associated with candidosis (p < 0.0001). Compared to women with normal flora, pruritus was more prevalent in women with candidosis (p < 0.0001), while vaginal odor was associated with bacterial vaginosis (p = 0.0026). The prevalence of atypical vaginal flora is common in our low-risk pregnant population and is not always associated with pathology. The occurrence of specific signs or symptoms does not always discriminate between women with different types of atypical vaginal flora or between those with abnormal and normal vaginal flora. Copyright © 2010 S. Karger AG, Basel.

  13. A Temperature-Monitoring Vaginal Ring for Measuring Adherence

    PubMed Central

    Boyd, Peter; Desjardins, Delphine; Kumar, Sandeep; Fetherston, Susan M.; Le-Grand, Roger; Dereuddre-Bosquet, Nathalie; Helgadóttir, Berglind; Bjarnason, Ásgeir; Narasimhan, Manjula; Malcolm, R. Karl

    2015-01-01

    Background Product adherence is a pivotal issue in the development of effective vaginal microbicides to reduce sexual transmission of HIV. To date, the six Phase III studies of vaginal gel products have relied primarily on self-reporting of adherence. Accurate and reliable methods for monitoring user adherence to microbicide-releasing vaginal rings have yet to be established. Methods A silicone elastomer vaginal ring prototype containing an embedded, miniature temperature logger has been developed and tested in vitro and in cynomolgus macaques for its potential to continuously monitor environmental temperature and accurately determine episodes of ring insertion and removal. Results In vitro studies demonstrated that DST nano-T temperature loggers encapsulated in medical grade silicone elastomer were able to accurately and continuously measure environmental temperature. The devices responded quickly to temperature changes despite being embedded in different thickness of silicone elastomer. Prototype vaginal rings measured higher temperatures compared with a subcutaneously implanted device, showed high sensitivity to diurnal fluctuations in vaginal temperature, and accurately detected periods of ring removal when tested in macaques. Conclusions Vaginal rings containing embedded temperature loggers may be useful in the assessment of product adherence in late-stage clinical trials. PMID:25965956

  14. Unraveling the Dynamics of the Human Vaginal Microbiome

    PubMed Central

    Nunn, Kenetta L.; Forney, Larry J.

    2016-01-01

    Four Lactobacillus species, namely L. crispatus, L. iners, L. gasseri, and L. jensenii, commonly dominate the vaginal communities of most reproductive-age women. It is unclear why these particular species, and not others, are so prevalent. Historically, estrogen-induced glycogen production by the vaginal epithelium has been proffered as being key to supporting the proliferation of vaginal lactobacilli. However, the ‘fly in the ointment’ (that has been largely ignored) is that the species of Lactobacillus commonly found in the human vagina cannot directly metabolize glycogen. It would appear that this riddle has been solved as studies have demonstrated that vaginal lactobacilli can metabolize the products of glycogen depolymerization by α-amylase, and fortunately, amylase activity is found in vaginal secretions. These amylases are presumed to be host-derived, but we suggest that other bacterial populations in vaginal communities could also be sources of amylase in addition to (or instead of) the host. Here we briefly review what is known about human vaginal bacterial communities and discuss how glycogen-derived resources and resource competition might shape the composition and structure of these communities. PMID:27698617

  15. Resolution of Rectal Prolapse by Vaginal Reconstruction.

    PubMed

    Devakumar, Hemikaa; Chandrasekaran, Neeraja; Alas, Alexandriah; Martin, Laura; Davila, G Willy; Hurtado, Eric

    Rectal prolapse is a disorder of the pelvic floor in which the layers of the rectal mucosa protrude outward through the anus. Surgical repair is the mainstay of treatment. Options include intra-abdominal procedures such as rectopexy and perineal procedures such as the Delorme and Altemeier perineal rectosigmoidectomy. Rectal and vaginal prolapse can often coexist. However, to our knowledge, there are no reported cases of rectal prolapse resolved by the repair of a compressive enterocele abutting the anterior rectal wall through a vaginal approach alone. We present a novel case of rectal prolapse that resolved by correction of the vaginal defect. A 53-year-old female with prior history of abdominal hysterectomy, presented to the urogynecology clinic with complaints of vaginal bulge, urge urinary incontinence, and rectal bulge on straining with no fecal incontinence for several years. On physical examination, she was found to have stage 2 anterior, posterior, and apical vaginal prolapse and reducible rectal prolapse. Colorectal surgery (CRS) evaluation was requested, which revealed minimal anterior mucosal prolapse on Valsalva with no full-thickness prolapse. Magnetic resonance imaging (MRI) defecogram was performed, which demonstrated a large rectocele, enterocele, and small bowel prolapsing between the rectum and vagina during the evacuation phase, with no rectal prolapse. The decision to proceed with vaginal prolapse surgery without concomitant rectal prolapse repair was made, as the patient had no fecal incontinence, and the degree of rectal prolapse was minimal. On the day of surgery, which was 2 months later, she presented with a 2-cm anterior rectal prolapse with no incontinence. Colorectal surgery was consulted again, but unavailable. After counseling, the patient wished to proceed with her planned surgery. It was felt that correcting the anterior rectocele and enterocele, thereby eliminating the descent of the bowel on the anterior rectal wall, might cause

  16. A Murine Model of Group B Streptococcus Vaginal Colonization.

    PubMed

    Patras, Kathryn A; Doran, Kelly S

    2016-11-16

    Streptococcus agalactiae (group B Streptococcus, GBS), is a Gram-positive, asymptomatic colonizer of the human gastrointestinal tract and vaginal tract of 10 - 30% of adults. In immune-compromised individuals, including neonates, pregnant women, and the elderly, GBS may switch to an invasive pathogen causing sepsis, arthritis, pneumonia, and meningitis. Because GBS is a leading bacterial pathogen of neonates, current prophylaxis is comprised of late gestation screening for GBS vaginal colonization and subsequent peripartum antibiotic treatment of GBS-positive mothers. Heavy GBS vaginal burden is a risk factor for both neonatal disease and colonization. Unfortunately, little is known about the host and bacterial factors that promote or permit GBS vaginal colonization. This protocol describes a technique for establishing persistent GBS vaginal colonization using a single β-estradiol pre-treatment and daily sampling to determine bacterial load. It further details methods to administer additional therapies or reagents of interest and to collect vaginal lavage fluid and reproductive tract tissues. This mouse model will further the understanding of the GBS-host interaction within the vaginal environment, which will lead to potential therapeutic targets to control maternal vaginal colonization during pregnancy and to prevent transmission to the vulnerable newborn. It will also be of interest to increase our understanding of general bacterial-host interactions in the female vaginal tract.

  17. In vitro activity of farnesol against vaginal Lactobacillus spp.

    PubMed

    Wang, Fengjuan; Liu, Zhaohui; Zhang, Dai; Niu, Xiaoxi

    2017-05-01

    Farnesol, a quorum-sensing molecule in Candida albicans, can affect the growth of certain microorganisms. The objective of this study was to evaluate the in vitro activity of farnesol against vaginal Lactobacillus spp., which play a crucial role in the maintenance of vaginal health. Growth and metabolic viability of vaginal Lactobacillus spp. incubated with different concentrations of farnesol were determined by measuring the optical density of the cultures and with the MTT assay. Morphology of the farnesol-treated cells was evaluated using a scanning electron microscope. In vitro adherence of vaginal Lactobacillus cells treated with farnesol was determined by co-incubating with vaginal epithelial cells (VECs). The minimum inhibitory concentration (MIC) of farnesol for vaginal Lactobacillus spp. was 1500μM. No morphological changes were observed when the farnesol-treated Lactobacillus cells were compared with farnesol-free cells, and 100μM farnesol would reduce the adherence of vaginal Lactobacillus to VECs. Farnesol acted as a potential antimicrobial agent, had little impact on the growth, metabolism, and cytomorphology of the vaginal Lactobacillus spp.; however, it affected their adhering capacity to VECs. The safety of farnesol as an adjuvant for antimicrobial agents during the treatment of vaginitis needs to be studied further. Copyright © 2017 Elsevier B.V. All rights reserved.

  18. VBAC (Vaginal Birth After C-Section)

    MedlinePlus

    Vaginal birth after C-section (VBAC) Overview If you've delivered a baby by C-section and you're pregnant again, you might be able to choose between scheduling a repeat C-section or attempting vaginal birth after C-section ( ...

  19. Clinical and microbiological correlates of vaginal trichomoniasis during pregnancy. The Vaginal Infections and Prematurity Study Group.

    PubMed

    Pastorek, J G; Cotch, M F; Martin, D H; Eschenbach, D A

    1996-11-01

    Colonization with Trichomonas vaginalis is a possible cause of poor pregnancy outcome. To facilitate the diagnosis of this condition during pregnancy, we conducted a prospective, multicenter study of 13,816 gravid women who were between 23rd and 26th week of gestation. Findings significantly associated with T. vaginalis colonization included a yellow, green, or bloody discharge from the vagina or cervix; abnormal odor after KOH was added to a vaginal specimen; a vaginal pH of > 5.0; and cervical friability. The amount of vaginal discharge and abnormal consistency of the discharge were also associated with T. vaginalis colonization. These findings (except for cervical bleeding and odor after the addition of KOH to a vaginal specimen, which may be influenced by the presence of other flora) are consistent with those reported elsewhere. The clinical usefulness of these features is minimal, and it is more significant that other microorganisms are makers for trichomoniasis; therefore, controlling for other flora is important in the investigation of T. vaginalis colonization.

  20. Brachytherapy Application With In Situ Dose Painting Administered by Gold Nanoparticle Eluters

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Sinha, Neeharika; Cifter, Gizem; Department of Radiation Oncology, Dana-Farber Cancer Institute, Brigham and Women's Hospital and Harvard Medical School, Boston, Massachusetts

    Purpose: Recent studies show promise that administering gold nanoparticles (GNP) to tumor cells during brachytherapy could significantly enhance radiation damage to the tumor. A new strategy proposed for sustained administration of the GNP in prostate tumors is to load them into routinely used brachytherapy spacers for customizable in situ release after implantation. This in silico study investigated the intratumor biodistribution and corresponding dose enhancement over time due to GNP released from such GNP-loaded brachytherapy spacers (GBS). Method and Materials: An experimentally determined intratumoral diffusion coefficient (D) for 10-nm nanoparticles was used to estimate D for other sizes by using themore » Stokes-Einstein equation. GNP concentration profiles, obtained using D, were then used to calculate the corresponding dose enhancement factor (DEF) for each tumor voxel, using dose painting-by-numbers approach, for times relevant to the considered brachytherapy sources' lifetimes. The investigation was carried out as a function of GNP size for the clinically applicable low-dose-rate brachytherapy sources iodine-125 (I-125), palladium-103 (Pd-103), and cesium-131 (Cs-131). Results: Results showed that dose enhancement to tumor voxels and subvolumes during brachytherapy can be customized by varying the size of GNP released or eluted from the GBS. For example, using a concentration of 7 mg/g GNP, significant DEF (>20%) could be achieved 5 mm from a GBS after 5, 12, 25, 46, 72, 120, and 195 days, respectively, for GNP sizes of 2, 5, 10, 20, 30, and 50 nm and for 80 nm when treating with I-125. Conclusions: Analyses showed that using Cs-131 provides the highest dose enhancement to tumor voxels. However, given its relatively longer half-life, I-125 presents the most flexibility for customizing the dose enhancement as a function of GNP size. These findings provide a useful reference for further work toward development of potential new brachytherapy

  1. Dual-Force Vaginoplasty for Treatment of Segmental Vaginal Aplasia.

    PubMed

    El Saman, Ali M; Farag, Mohamad A; Shazly, Sherif A; Noor, Mohamed; Ali, Mohammed K; Othman, Essam R; Khalifa, Mansour; Farghly, Tarek A; El Saman, Dina A

    2017-05-01

    Vaginal aplasia occurs in 1 in 5,000-10,000 female live births. In this report, we evaluated a novel dual-force vaginoplasty technique for treatment of 11 patients with segmental vaginal aplasia. The principle of the approach is to thin the atretic part between two counteracting forces. The instrument was inserted laparoscopically into the proximal hematocolpos. Two balloon catheters, one for drainage and one for traction, were threaded over the inserter. The traction catheter was then threaded over a silicon tube, leaving the balloon in the proximal portion of the vagina and connecting across the vaginal septum to a fenestrated Teflon olive, which was positioned against the distal surface of the vaginal septum. This created a dual "pushing and pulling" force across the septum, which, over 3-4 days, pulls the upper vaginal pouch down while the vaginal dimple is pushed up. The aplastic segment becomes thin and easy to dilate and permits achievement of vaginal patency. The drainage of the hematocolpos is predominantly through the balloon catheter so postoperative wound management is facilitated. Eleven menarchal girls were diagnosed with segmental vaginal aplasia. The dual-force vaginoplasty was performed on each and was tolerated well with no operative complications. They all reported establishment of the menstrual cycle and significant improvement of pain during follow-up. Creation of a dual pushing-pulling force on the atretic vaginal segment is a feasible short procedure for management of segmental vaginal aplasia.

  2. An investigation of crankshaft oscillations for cylinder health diagnostics

    NASA Astrophysics Data System (ADS)

    Geveci, Mert; Osburn, Andrew W.; Franchek, Matthew A.

    2005-09-01

    The vibrational characteristics of an internal combustion engine crankshaft are investigated from a cylinder health diagnostics point of view. Experimental results from a six-cylinder industrial diesel engine are presented to demonstrate the effects of cylinder imbalance on the individual harmonic components of the engine speed signal. A crank-angle domain numerical model of the crankshaft dynamics for a six-cylinder industrial diesel engine is also adopted to establish the effects of continuous low-power production in individual cylinders of a multi-cylinder engine. Outline of a diagnostics algorithm that makes use of the properties of crankshaft vibration behaviour is provided. In particular, crank-angle domain notch filters are employed to extact the harmonic components of engine speed. The outlined method can be implemented for individual cylinder health diagnostics across a family of multi-cylinder engines and can be formulated to handle changes in crankshaft characteristics due to replacement of mechanical components and/or wear.

  3. 49 CFR 178.68 - Specification 4E welded aluminum cylinders.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... to cylinder by welding by inert gas shielded arc process or by threads. If threads are used, they... process and cylinders with longitudinal seams are not authorized. (b) Authorized material. The cylinder...'s lot number. (d) Manufacture. Cylinders must be manufactured using equipment and processes adequate...

  4. 49 CFR 178.68 - Specification 4E welded aluminum cylinders.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... to cylinder by welding by inert gas shielded arc process or by threads. If threads are used, they... process and cylinders with longitudinal seams are not authorized. (b) Authorized material. The cylinder...'s lot number. (d) Manufacture. Cylinders must be manufactured using equipment and processes adequate...

  5. 49 CFR 178.68 - Specification 4E welded aluminum cylinders.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... to cylinder by welding by inert gas shielded arc process or by threads. If threads are used, they... process and cylinders with longitudinal seams are not authorized. (b) Authorized material. The cylinder...'s lot number. (d) Manufacture. Cylinders must be manufactured using equipment and processes adequate...

  6. Flow past a rotating cylinder

    NASA Astrophysics Data System (ADS)

    Mittal, Sanjay; Kumar, Bhaskar

    2003-02-01

    Flow past a spinning circular cylinder placed in a uniform stream is investigated via two-dimensional computations. A stabilized finite element method is utilized to solve the incompressible Navier Stokes equations in the primitive variables formulation. The Reynolds number based on the cylinder diameter and free-stream speed of the flow is 200. The non-dimensional rotation rate, [alpha] (ratio of the surface speed and freestream speed), is varied between 0 and 5. The time integration of the flow equations is carried out for very large dimensionless time. Vortex shedding is observed for [alpha] < 1.91. For higher rotation rates the flow achieves a steady state except for 4.34 < [alpha] < 4:70 where the flow is unstable again. In the second region of instability, only one-sided vortex shedding takes place. To ascertain the instability of flow as a function of [alpha] a stabilized finite element formulation is proposed to carry out a global, non-parallel stability analysis of the two-dimensional steady-state flow for small disturbances. The formulation and its implementation are validated by predicting the Hopf bifurcation for flow past a non-rotating cylinder. The results from the stability analysis for the rotating cylinder are in very good agreement with those from direct numerical simulations. For large rotation rates, very large lift coefficients can be obtained via the Magnus effect. However, the power requirement for rotating the cylinder increases rapidly with rotation rate.

  7. Chitosan Ascorbate Nanoparticles for the Vaginal Delivery of Antibiotic Drugs in Atrophic Vaginitis

    PubMed Central

    Vigani, Barbara; Puccio, Antonella; Ferrari, Franca

    2017-01-01

    The aim of the present work was the development of chitosan ascorbate nanoparticles (CSA NPs) loaded into a fast-dissolving matrix for the delivery of antibiotic drugs in the treatment of atrophic vaginitis. CSA NPs loaded with amoxicillin trihydrate (AX) were obtained by ionotropic gelation in the presence of pentasodium tripolyphosphate (TPP). Different CSA:TPP and CSA:AX weight ratios were considered and their influence on the particle size, polydispersion index and production yield were investigated. CSA NPs were characterized for mucoadhesive, wound healing and antimicrobial properties. Subsequently, CSA NPs were loaded in polymeric matrices, whose composition was optimized using a DoE (Design of Experiments) approach (simplex centroid design). Matrices were obtained by freeze-drying aqueous solutions of three hydrophilic excipients, polyvinylpirrolidone, mannitol and glycin. They should possess a mechanical resistance suitable for the administration into the vaginal cavity and should readily dissolve in the vaginal fluid. In addition to antioxidant properties, due to the presence of ascorbic acid, CSA NPs showed in vitro mucoadhesive, wound healing and antimicrobial properties. In particular, nanoparticles were characterized by an improved antimicrobial activity with respect to a chitosan solution, prepared at the same concentration. The optimized matrix was characterized by mechanical resistance and by the fast release in simulated vaginal fluid of nanoparticles characterized by unchanged size. PMID:29048359

  8. [Etiology of bacterial vaginosis (non-specific vaginitis)].

    PubMed

    Lefèvre, J C; Jean, M; Averous, S; Viraben, R; Blanc, C; Bauriaud, R; Lareng, M B

    1985-01-01

    56 women who were diagnosed bioclinically as having a bacterial vaginal infection were studied, as were 35 women as a control group. The study was a semi-quantitative analysis of the vaginal bacterial flora, both aerobic and anaerobic. It shows that Gardnerella vaginalis and anaerobic bacteria such as Peptococcus, Peptostreptococcus, Bacteroïdes, Veillonella and Mobiluncus were associated in a statistically significant way with bacterial vaginitis. On the other hand Lactobacilli were less frequently found (p less than 0.001) than in the control group of women. The way in which the microbial flora is changed has been observed during attacks of vaginitis and is discussed, as is the importance of making the diagnosis and of treating this syndrome.

  9. Brachytherapy in Head and Neck Cancers: "Are We Doing It or Are We Done with It".

    PubMed

    Kirthi Koushik, A S; Alva, Ram Charith

    2018-06-01

    We performed an e-Survey and reviewed the literature on the prevalence of use of brachytherapy in head and neck cancers in order to understand the patterns of care and probable application of this modality. A five-point questionnaire was prepared and sent to 300 oncologists through a web-based survey engine. This was done in preparation for my lecture on "Ongoing Research and Potential Research Avenues" in IBSCON held in Chennai in August 2016. SPSS software was used for the statistical analysis. Of a total of 300 emails that were sent out for the survey, 120 replies were received, which is 40%. Among the results of various questions, (i) 65% of the oncologists felt that there were > 300 ongoing studies in brachytherapy and out of them only 10-20 were on head and neck brachytherapy; (ii) 58% of the responders felt that external beam radiotherapy (EBRT) advances followed by lack of training and experience are the reasons for declining role of brachytherapy; (iii) among the responders, numbers of head and neck brachytherapy performed stand third after gynecological and breast brachytherapy. This survey shows that brachytherapy in head and neck cancers is an essential tool, but seldom practiced. If no path-breaking event happens, we may be dealing with it as a dying art.

  10. Aerobic vaginitis in pregnancy.

    PubMed

    Donders, Ggg; Bellen, G; Rezeberga, D

    2011-09-01

    Aerobic vaginitis (AV) is an alteration in vaginal bacterial flora that differs from bacterial vaginosis (BV). AV is characterised by an abnormal vaginal microflora accompanied by an increased localised inflammatory reaction and immune response, as opposed to the suppressed immune response that is characteristic of BV. Given the increased local production of interleukin (IL)-1, IL-6 and IL-8 associated with AV during pregnancy, not surprisingly AV is associated with an increased risk of preterm delivery, chorioamnionitis and funisitis of the fetus. There is no consensus on the optimal treatment for AV in pregnant or non-pregnant women, but a broader spectrum drug such as clindamycin is preferred above metronidazole to prevent infection-related preterm birth. The exact role of AV in pregnancy, the potential benefit of screening, and the use of newer local antibiotics, disinfectants, probiotics and immune modulators need further study. © 2011 The Authors BJOG An International Journal of Obstetrics and Gynaecology © 2011 RCOG.

  11. A Visual Photographic Study of Cylinder Lubrication

    NASA Technical Reports Server (NTRS)

    Shaw, Milton C; Nussdorfer, Theodore

    1946-01-01

    A V-type engine provided with a glass cylinder was used to study visually the lubrication characteristics of an aircraft-type piston. Photographs and data were obtained with the engine motored at engine speeds up to 1000 r.p.m. and constant cylinder-head pressures of 0 and 50 pounds per square inch. A study was made of the orientation of the piston under various operating conditions, which indicated that the piston was inclined with the crown nearest the major-thrust cylinder face throughout the greater part of the cycle. The piston moved laterally in the cylinder under the influence of piston side thrust.

  12. Progesterone for Luteal Phase Support in In Vitro Fertilization: Comparison of Vaginal and Rectal Pessaries to Vaginal Capsules: A Randomized Controlled Study

    PubMed Central

    Khrouf, Mohamed; Slimani, Soufiene; Khrouf, Myriam Razgallah; Braham, Marouen; Bouyahia, Maha; Berjeb, Khadija Kacem; Chaabane, Hanene Elloumi; Merdassi, Ghaya; Kaffel, Aida Zahaf; Zhioua, Amel; Zhioua, Fethi

    2016-01-01

    BACKGROUND In IVF, Luteal phase support is usually performed using vaginal progesterone. A part of patients using this route reports being uncomfortable with this route. We tried to study whether the rectal route could be an effective alternative and associated with less discomfort. PATIENTS AND METHODS A prospective randomized controlled study. All patient were eligible for IVF treatment for infertility. After oocyte pickup, 186 patients were allocated to one the following protocols for luteal phase support: (i) rectal pessaries group: natural progesterone pessaries administered rectally 200 mg three times a day, (ii) vaginal pessaries group: natural progesterone pessaries administered vaginally 200 mg three times a day), and (iii) vaginal capsules group: natural micronized progesterone capsules administered vaginally 200 mg three times a day. On the day of pregnancy test, patients were asked to fill in a questionnaire conducted by an investigator in order to assess the tolerability and side effects of the LPS treatment taken. The primary endpoint was the occurrence of perineal irritation. RESULTS Fifty eight patients were assigned to the rectal pessaries group, 68 patients to the vaginal pessaries group, and 60 patients to the vaginal capsules group. All patients adhered to their allocated treatment. Implantation and clinical pregnancy rates per transfer did not differ between the three groups. Perineal irritation, which was our primary endpoint, was the same for all the three groups (respectively 1.7 % versus 5.9 % versus 11.7%). Regarding the other side effects, more patients experienced constipation and flatulence with the rectal route, whereas more patients reported vaginal discharge in the vaginal capsules group. CONCLUSION Rectal administration for luteal phase support is effective and well accepted alternative to vaginal route. PMID:28096703

  13. Progesterone for Luteal Phase Support in In Vitro Fertilization: Comparison of Vaginal and Rectal Pessaries to Vaginal Capsules: A Randomized Controlled Study.

    PubMed

    Khrouf, Mohamed; Slimani, Soufiene; Khrouf, Myriam Razgallah; Braham, Marouen; Bouyahia, Maha; Berjeb, Khadija Kacem; Chaabane, Hanene Elloumi; Merdassi, Ghaya; Kaffel, Aida Zahaf; Zhioua, Amel; Zhioua, Fethi

    2016-01-01

    In IVF, Luteal phase support is usually performed using vaginal progesterone. A part of patients using this route reports being uncomfortable with this route. We tried to study whether the rectal route could be an effective alternative and associated with less discomfort. A prospective randomized controlled study. All patient were eligible for IVF treatment for infertility. After oocyte pickup, 186 patients were allocated to one the following protocols for luteal phase support: (i) rectal pessaries group: natural progesterone pessaries administered rectally 200 mg three times a day, (ii) vaginal pessaries group: natural progesterone pessaries administered vaginally 200 mg three times a day), and (iii) vaginal capsules group: natural micronized progesterone capsules administered vaginally 200 mg three times a day. On the day of pregnancy test, patients were asked to fill in a questionnaire conducted by an investigator in order to assess the tolerability and side effects of the LPS treatment taken. The primary endpoint was the occurrence of perineal irritation. Fifty eight patients were assigned to the rectal pessaries group, 68 patients to the vaginal pessaries group, and 60 patients to the vaginal capsules group. All patients adhered to their allocated treatment. Implantation and clinical pregnancy rates per transfer did not differ between the three groups. Perineal irritation, which was our primary endpoint, was the same for all the three groups (respectively 1.7 % versus 5.9 % versus 11.7%). Regarding the other side effects, more patients experienced constipation and flatulence with the rectal route, whereas more patients reported vaginal discharge in the vaginal capsules group. Rectal administration for luteal phase support is effective and well accepted alternative to vaginal route.

  14. SU-F-T-29: The Important of Each Fraction Image-Guided Planning for Postoperative HDR-Brachytherapy in Endometrial Carcinoma

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Piriyasang, D; Pattaranutaporn, P; Manokhoon, K

    2016-06-15

    Purpose: Cylindrical applicators are often used for postoperative HDRbrachytherapy in endometrial carcinoma. It has been considered that dosimetric variation between fractions for this treatment is minimal and might not be necessary to perform treatment planning for every fractions. At our institute, it is traditional to perform treatment planning with CT simulation on the first fraction and uses this plan for the rest of treatment. This study was aim to evaluate the errors of critical structure doses between the fractions when simulation and planning were done for first fraction only. Methods: Treatment plans of 10 endometrial carcinoma patients who received postoperativemore » HDR-brachytherapy and underwent CT-simulation for every HDR-fractions at our department were retrospectively reviewed. All of these patients were treated with cylindrical applicator and prescribed dose 15Gy in 3 fractions to 0.5cm from vaginal surface. The treatment plan from the first fraction was used to simulate in second and third CT-simulation. Radiation dose for critical structures in term of Dose-to-2cc (D2cc) were evaluated and compared between planning CT. Results: The D2cc for bladder and rectum were evaluated. For bladder, the mean error of D2cc estimation for second and third fractions was 7.6% (0.1–20.1%, SD=5.7). And the mean error for D2cc of rectum was 8.5% (0.1–29.4%, SD=8.5). Conclusion: The critical structure doses could be significant difference between fractions which may affects treatment outcomes or toxicities. From our data, image-guided brachytherapy at least with CT-Simulation should be done for every treatment fractions.« less

  15. Vaginal microbial flora and outcome of pregnancy.

    PubMed

    Donati, Laura; Di Vico, Augusto; Nucci, Marta; Quagliozzi, Lorena; Spagnuolo, Terryann; Labianca, Antonietta; Bracaglia, Marina; Ianniello, Francesca; Caruso, Alessandro; Paradisi, Giancarlo

    2010-04-01

    The vaginal microflora of a healthy asymptomatic woman consists of a wide variety of anaerobic and aerobic bacterial genera and species dominated by the facultative, microaerophilic, anaerobic genus Lactobacillus. The activity of Lactobacillus is essential to protect women from genital infections and to maintain the natural healthy balance of the vaginal flora. Increasing evidence associates abnormalities in vaginal flora during pregnancy with preterm labor and delivery with potential neonatal sequelae due to prematurity and poor perinatal outcome. Although this phenomenon is relatively common, even in populations of women at low risk for adverse events, the pathogenetic mechanism that leads to complications in pregnancy is still poorly understood. This review summarizes the current knowledge and uncertainties in defining alterations of vaginal flora in non-pregnant adult women and during pregnancy, and, in particular, investigates the issue of bacterial vaginosis and aerobic vaginitis. This could help specialists to identify women amenable to treatment during pregnancy leading to the possibility to reduce the preterm birth rate, preterm premature rupture of membranes, chorioamnionitis, neonatal, puerperal and maternal-fetal infectious diseases. Vaginal ecosystem study with the detection of pathogens is a key instrument in the prevention of preterm delivery, pPROM, chorioamnionitis, neonatal, puerperal and maternal-fetal infections.

  16. CNG Cylinder Safety - Education, Outreach, and Next Steps (Presentation)

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Smith, M.; Schroeder, A.

    2014-01-01

    Mr. Schroeder discussed the work that NREL is performing for the U.S. Department of Transportation on compressed natural gas cylinder end-of-life requirements. CNG vehicles are different from most other vehicles in that the CNG fuel storage cylinders have a pre-determined lifetime that may be shorter than the expected life of the vehicle. The end-of-life date for a cylinder is based on construction and test protocols, and is specific to the construction and material of each cylinder. The end-of-life date is important because it provides a safe margin of error against catastrophic cylinder failure or rupture. The end-of-life dates range frommore » 15 to 25 years from the date of manufacture. NREL worked to develop outreach materials to increase awareness of cylinder end-of-life dates, has provided technical support for individual efforts related to cylinder safety and removal, and also worked with CVEF to document best practices for cylinder removal or inspection after an accident. Mr. Smith discussed the engagement of the DOE Clean Fleets Partners, which were surveyed to identify best practices on managing cylinder inventories and approached to provide initial data on cylinder age in a fleet environment. Both DOE and NREL will continue to engage these fleets and other stakeholders to determine how to best address this issue moving forward.« less

  17. Multihelix rotating shield brachytherapy for cervical cancer

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Dadkhah, Hossein; Kim, Yusung; Flynn, Ryan T., E-mail: ryan-flynn@uiowa.edu

    Purpose: To present a novel brachytherapy technique, called multihelix rotating shield brachytherapy (H-RSBT), for the precise angular and linear positioning of a partial shield in a curved applicator. H-RSBT mechanically enables the dose delivery using only linear translational motion of the radiation source/shield combination. The previously proposed approach of serial rotating shield brachytherapy (S-RSBT), in which the partial shield is rotated to several angular positions at each source dwell position [W. Yang et al., “Rotating-shield brachytherapy for cervical cancer,” Phys. Med. Biol. 58, 3931–3941 (2013)], is mechanically challenging to implement in a curved applicator, and H-RSBT is proposed as amore » feasible solution. Methods: A Henschke-type applicator, designed for an electronic brachytherapy source (Xoft Axxent™) and a 0.5 mm thick tungsten partial shield with 180° or 45° azimuthal emission angles and 116° asymmetric zenith angle, is proposed. The interior wall of the applicator contains six evenly spaced helical keyways that rigidly define the emission direction of the partial radiation shield as a function of depth in the applicator. The shield contains three uniformly distributed protruding keys on its exterior wall and is attached to the source such that it rotates freely, thus longitudinal translational motion of the source is transferred to rotational motion of the shield. S-RSBT and H-RSBT treatment plans with 180° and 45° azimuthal emission angles were generated for five cervical cancer patients with a diverse range of high-risk target volume (HR-CTV) shapes and applicator positions. For each patient, the total number of emission angles was held nearly constant for S-RSBT and H-RSBT by using dwell positions separated by 5 and 1.7 mm, respectively, and emission directions separated by 22.5° and 60°, respectively. Treatment delivery time and tumor coverage (D{sub 90} of HR-CTV) were the two metrics used as the basis for

  18. Multihelix rotating shield brachytherapy for cervical cancer

    PubMed Central

    Dadkhah, Hossein; Kim, Yusung; Wu, Xiaodong; Flynn, Ryan T.

    2015-01-01

    Purpose: To present a novel brachytherapy technique, called multihelix rotating shield brachytherapy (H-RSBT), for the precise angular and linear positioning of a partial shield in a curved applicator. H-RSBT mechanically enables the dose delivery using only linear translational motion of the radiation source/shield combination. The previously proposed approach of serial rotating shield brachytherapy (S-RSBT), in which the partial shield is rotated to several angular positions at each source dwell position [W. Yang et al., “Rotating-shield brachytherapy for cervical cancer,” Phys. Med. Biol. 58, 3931–3941 (2013)], is mechanically challenging to implement in a curved applicator, and H-RSBT is proposed as a feasible solution. Methods: A Henschke-type applicator, designed for an electronic brachytherapy source (Xoft Axxent™) and a 0.5 mm thick tungsten partial shield with 180° or 45° azimuthal emission angles and 116° asymmetric zenith angle, is proposed. The interior wall of the applicator contains six evenly spaced helical keyways that rigidly define the emission direction of the partial radiation shield as a function of depth in the applicator. The shield contains three uniformly distributed protruding keys on its exterior wall and is attached to the source such that it rotates freely, thus longitudinal translational motion of the source is transferred to rotational motion of the shield. S-RSBT and H-RSBT treatment plans with 180° and 45° azimuthal emission angles were generated for five cervical cancer patients with a diverse range of high-risk target volume (HR-CTV) shapes and applicator positions. For each patient, the total number of emission angles was held nearly constant for S-RSBT and H-RSBT by using dwell positions separated by 5 and 1.7 mm, respectively, and emission directions separated by 22.5° and 60°, respectively. Treatment delivery time and tumor coverage (D90 of HR-CTV) were the two metrics used as the basis for evaluation and

  19. Viscous free-surface flows on rotating elliptical cylinders

    NASA Astrophysics Data System (ADS)

    Li, Weihua; Carvalho, Marcio S.; Kumar, Satish

    2017-09-01

    The flow of liquid films on rotating discrete objects having complicated cross sections is encountered in coating processes for a broad variety of products. To advance fundamental understanding of this problem, we study viscous free-surface flows on rotating elliptical cylinders by solving the governing equations in a rotating reference frame using the Galerkin finite-element method. Results of our simulations agree well with Hunt's maximum-load condition [Hunt, Numer. Methods Partial Differ. Eqs. 24, 1094 (2008), 10.1002/num.20307], which was obtained in the absence of surface tension and inertia. The simulations are also used to track the transient behavior of the free surface. For O (1 ) cylinder aspect ratios, cylinder rotation results in a droplike liquid bulge hanging on the upward-moving side of the cylinder. This bulge shrinks in size due to surface tension provided that the liquid load is smaller than a critical value, leaving a relatively smooth coating on the cylinder. A decrease in cylinder aspect ratio leads to larger gradients in film thickness, but enhances the rate of bulge shrinkage and thus shortens the time required to obtain a smooth coating. Moreover, with a suitably chosen time-dependent rotation rate, more liquid can be supported by the cylinder relative to the constant-rotation-rate case. For cylinders with even smaller aspect ratios, film rupture and liquid shedding may occur over the cylinder tips, so simultaneous drying and rotation along with the introduction of Marangoni stresses will likely be especially important for obtaining a smooth coating.

  20. Vaginal hysterectomy with apical fixation and anterior vaginal wall repair for prolapse: surgical technique and medium-term results.

    PubMed

    Marschke, Juliane; Pax, Carlo Michael; Beilecke, Kathrin; Schwab, Frank; Tunn, Ralf

    2018-03-24

    Stabilization of the vaginal apex (level 1) is an important component of operations to correct pelvic organ prolapse (POP). We report functional and anatomical results and patient-reported outcomes of our technique of vaginal vault fixation at the time of vaginal hysterectomy. One hundred and nine patients-mean 69 years, range 50.4-83.8; body mass index (BMI) 26.3, range 17.7-39.5-with symptomatic stage 2-3 uterine prolapse combined with stage 3-4 cystocele underwent vaginal hysterectomy with anterior vaginal wall repair; the apex was formed with high closure of the peritoneum and incorporation of the uterosacral and round ligaments. Only absorbable sutures were used. Follow-up included clinical examination with Pelvic Organ Prolapse Quantification system (POP-Q) scoring, introital ultrasonography, quality of life (QoL) Likert scale, and the German Pelvic Floor Questionnaire. Seventy patients (64%) were available for a follow-up after a mean of 2.8 years (range, 1.6-4.2). At follow-up, point C was stage 0 in 55 (78.6%) women and stage 1 in 15 (21.4%). The anterior vaginal wall was stage 0 or 1 in 35 (50%), stage 2 (no cystocele beyond the hymen) in 34 (49%), and stage 3 in 1 (1.4%). Vaginal length (VL) was 9 cm. Four women (4%) were reoperated for prolapse: two for recurrent anterior compartment prolapse and two for de novo rectocele. Postvoid residuals >150 ml were seen in 21(30%) patients preoperatively and resolved postoperatively in 20. Urgency occurred in nine (13%), stress urinary incontinence (SUI) in ten (14%), and nocturia in 19 (27%). No patient had discomfort at the vaginal vault and 62 patients (87%) reported improved QoL, which did not correlate with anatomical results. Cystocele ≥ 2° at follow-up was associated with BMI >25 (p = 0.03). Our surgical technique without permanent material offers good apical support and functional and subjective results. Anatomical improvement was achieved in all cases of cystocele repair. Recurrent cystoceles

  1. Method for Making a Carbon-Carbon Cylinder Block

    NASA Technical Reports Server (NTRS)

    Ransone, Phillip O. (Inventor)

    1997-01-01

    A method for making a lightweight cylinder block composed of carbon-carbon is disclosed. The use of carbon-carbon over conventional materials. such as cast iron or aluminum, reduces the weight of the cylinder block and improves thermal efficiency of the internal combustion reciprocating engine. Due to the negligible coefficient of thermal expansion and unique strength at elevated temperatures of carbon-carbon, the piston-to-cylinder wall clearance can be small, especially when the carbon-carbon cylinder block is used in conjunction with a carbon-carbon piston. Use of the carbon-carbon cylinder block has the effect of reducing the weight of other reciprocating engine components allowing the piston to run at higher speeds and improving specific engine performance.

  2. Metronidazole Vaginal

    MedlinePlus

    ... is used to treat vaginal infections such as bacterial vaginosis (an infection caused from too much of certain bacteria in the vagina). Metronidazole is in a class of medications called nitroimidazole antimicrobials. It works by stopping the growth of bacteria.

  3. Scintillating fiber optic dosimeters for breast and prostate brachytherapy

    NASA Astrophysics Data System (ADS)

    Moutinho, L. M.; Castro, I. F.; Freitas, H.; Melo, J.; Silva, P.; Gonçalves, A.; Peralta, L.; Rachinhas, P. J.; Simões, P. C. P. S.; Pinto, S.; Pereira, A.; Santos, J. A. M.; Costa, M.; Veloso, J. F. C. A.

    2017-02-01

    Brachytherapy is a radiotherapy modality where the radioactive material is placed close to the tumor, being a common treatment for skin, breast, gynecological and prostate cancers. These treatments can be of low-dose-rate, using isotopes with mean energy of 30 keV, or high-dose-rate, using isotopes such as 192Ir with a mean energy of 380 keV. Currently these treatments are performed in most cases without in-vivo dosimetry for quality control and quality assurance. We developed a dosimeter using small diameter probes that can be inserted into the patient's body using standard brachytherapy needles. By performing real-time dosimetry in breast and prostate brachytherapy it will be possible to perform real-time dose correction when deviations from the treatment plan are observed. The dosimeter presented in this work was evaluated in-vitro. The studies consisted in the characterization of the dosimeter with 500 μm diameter sensitive probes (with a BCF-12 scintillating optical fiber) using an inhouse made gelatin breast phantom with a volume of 566 cm3. A breast brachytherapy treatment was simulated considering a tumor volume of 27 cm3 and a prescribed absolute dose of 5 Gy. The dose distribution was determined by the Inverse Planning Simulated Annealing (IPSA) optimization algorithm (ELEKTA). The dwell times estimated from the experimental measurements are in agreement with the prescribed dwell times, with relative error below 3%. The measured signal-to-noise ratio (SNR) including the stem-effect contribution is below 3%.

  4. Interventional Radiation Oncology (IRO): Transition of a magnetic resonance simulator to a brachytherapy suite.

    PubMed

    Anderson, Roberta; Armour, Elwood; Beeckler, Courtney; Briner, Valerie; Choflet, Amanda; Cox, Andrea; Fader, Amanda N; Hannah, Marie N; Hobbs, Robert; Huang, Ellen; Kiely, Marilyn; Lee, Junghoon; Morcos, Marc; McMillan, Paige E; Miller, Dave; Ng, Sook Kien; Prasad, Rashmi; Souranis, Annette; Thomsen, Robert; DeWeese, Theodore L; Viswanathan, Akila N

    As a core component of a new gynecologic cancer radiation program, we envisioned, structured, and implemented a novel Interventional Radiation Oncology (IRO) unit and magnetic resonance (MR)-brachytherapy environment in an existing MR simulator. We describe the external and internal processes required over a 6-8 month time frame to develop a clinical and research program for gynecologic brachytherapy and to successfully convert an MR simulator into an IRO unit. Support of the institution and department resulted in conversion of an MR simulator to a procedural suite. Development of the MR gynecologic brachytherapy program required novel equipment, staffing, infrastructural development, and cooperative team development with anesthetists, nurses, therapists, physicists, and physicians to ensure a safe and functional environment. Creation of a separate IRO unit permitted a novel billing structure. The creation of an MR-brachytherapy environment in an MR simulator is feasible. Developing infrastructure includes several collaborative elements. Unique to the field of radiation oncology, formalizing the space as an Interventional Radiation Oncology unit permits a sustainable financial structure. Copyright © 2018 American Brachytherapy Society. Published by Elsevier Inc. All rights reserved.

  5. Treating Locally Advanced Cervical Cancer With Concurrent Chemoradiation Without Brachytherapy in Low-resource Countries.

    PubMed

    Chuang, Linus; Kanis, Margaux J; Miller, Brigitte; Wright, Jason; Small, William; Creasman, William

    2016-02-01

    To summarize the literature on options of management of patients treated for locally advanced cervical cancers with a specific focus on resource-constrained settings where brachytherapy is not available. A Medline search was performed to summarize studies about treatment approaches including neoadjuvant chemotherapy, primary surgery for bulky cervical cancer, and chemoradiation followed by surgery. Summaries are by treatment approaches that are relevant to resource-constrained settings. There are a lack of studies performed on neoadjuvant chemotherapy in low-resource settings. Primary surgery followed by chemoradiation therapy for selected patients with bulky cervical cancer is a feasible option. The disadvantage is the potential increase in treatment complications. Chemoradiation without brachytherapy followed by surgery has been found to have equivalent outcomes and is associated with acceptable morbidity. In resource-constrained settings where brachytherapy is not available, performing radical hysterectomy after chemoradiation therapy without brachytherapy has been shown to produce equivalent outcomes. It seems reasonable to adopt a modified therapeutic protocol of chemoradiation followed by extrafascial hysterectomy as an alternative treatment option in low-resource countries where brachytherapy is not readily available.

  6. Analysis of the Oxidative Stress Status in Nonspecific Vaginitis and Its Role in Vaginal Epithelial Cells Apoptosis

    PubMed Central

    Chen, Zhaojie; Zhang, Zhen; Zhang, Haiyan; Xie, Beibei

    2015-01-01

    Nonspecific vaginitis (NSV), also named bacterial vaginosis, is one of the most common genital system diseases in women during their reproductive years. The specific pathogenic mechanism of NSV is not clear yet. Upon the balance alteration, large amount of reactive oxidant species (ROS) is generated and accumulated in the genital tract, and thus resulting in oxidative stress, which has been reported to be an important trigger of mitochondrial pathway cell apoptosis. In this study, the antioxidant secretion level and antioxidant enzyme activity in the vaginal discharge were evaluated to analyze the oxidative status in the vaginal tract of NSV patients. The effect of oxidative stress on the vaginal mucosa epithelial cell apoptosis was then studied. The role of oxidative stress on NSV development was uncovered; thus open new direction for the prevention and treatment of NSV by providing antiradical agents was revealed. PMID:26558281

  7. Relieving menstrual obstruction: surgical correction of vaginal agenesis.

    PubMed

    Schmitt, Jennifer J; Arora, Chetna; Gebhart, John B

    2016-04-01

    Mayer-Rokitansky-Küster-Hauser (MRKH) syndrome includes vaginal agenesis with varied uterine development. The objective of this video is to illustrate our surgical technique to create a cervical and vaginal canal to relieve menstrual obstruction for a teenager with a functional uterus and vaginal agenesis. Using vaginal dissection and a mini laparotomy, a sound placed through the fundus of the uterus created an endocervical and vaginal channel to relieve her menstrual obstruction. A Foley catheter stented the cervical canal and a red rubber chest tube catheter stented the vagina until epithelization was achieved. No complications were encountered. The patient was examined with intermittent hysteroscopy with gentle dilation of the cervix. She had the red rubber catheter removed at 3 months, and she started using a small dilator. Her menses were suppressed with a gonadotropin releasing-hormone agonist allowing for complete healing. She is now 17. Her vaginal canal is well-epithelialized. Hysteroscopy confirmed a patent endocervical canal and uterine cavity. MRKH is rare. A small percentage of affected women has a functional endometrium requiring intervention for menstrual obstruction. Full vaginal reconstruction may be considered, but creation of a small canal to provide menstrual relief can be a temporary solution in those not desiring sexual function.

  8. 21 CFR 884.5900 - Therapeutic vaginal douche apparatus.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Therapeutic vaginal douche apparatus. 884.5900... Devices § 884.5900 Therapeutic vaginal douche apparatus. (a) Identification. A therapeutic vaginal douche apparatus is a device that is a bag or bottle with tubing and a nozzle. The apparatus does not include...

  9. 21 CFR 884.5900 - Therapeutic vaginal douche apparatus.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Therapeutic vaginal douche apparatus. 884.5900... Devices § 884.5900 Therapeutic vaginal douche apparatus. (a) Identification. A therapeutic vaginal douche apparatus is a device that is a bag or bottle with tubing and a nozzle. The apparatus does not include...

  10. Charging Characteristics of an Insulating Hollow Cylinder in Vacuum

    NASA Astrophysics Data System (ADS)

    Yamamoto, Osamu; Hayashi, Hirotaka; Wadahama, Toshihiko; Takeda, Daisuke; Hamada, Shoji; Ohsawa, Yasuharu

    This paper deals with charging characteristics of the inner surface of an insulating hollow cylinder in vacuum. We conducted measurements of electric field strength near the triple points on cathode by using an electrostatic probe. Also we conducted a computer simulation of charging based on the Secondary Electron Emission Avalanche (SEEA) mechanism. These results are compared with those obtained previously for solid cylinders. As a result, we have clarified that hollow cylinders acquire surface charge which is larger than that of solid cylinders. We have also found that charge controlling effect by roughening the inner surface, which have been proved effective to depress charging on the surface of solid cylinders in our previous studies, is limited for hollow cylinders.

  11. Theory of interacting dislocations on cylinders.

    PubMed

    Amir, Ariel; Paulose, Jayson; Nelson, David R

    2013-04-01

    We study the mechanics and statistical physics of dislocations interacting on cylinders, motivated by the elongation of rod-shaped bacterial cell walls and cylindrical assemblies of colloidal particles subject to external stresses. The interaction energy and forces between dislocations are solved analytically, and analyzed asymptotically. The results of continuum elastic theory agree well with numerical simulations on finite lattices even for relatively small systems. Isolated dislocations on a cylinder act like grain boundaries. With colloidal crystals in mind, we show that saddle points are created by a Peach-Koehler force on the dislocations in the circumferential direction, causing dislocation pairs to unbind. The thermal nucleation rate of dislocation unbinding is calculated, for an arbitrary mobility tensor and external stress, including the case of a twist-induced Peach-Koehler force along the cylinder axis. Surprisingly rich phenomena arise for dislocations on cylinders, despite their vanishing Gaussian curvature.

  12. Vaginal delivery among women who underwent labor induction with vaginal dinoprostone (PGE2) insert: a retrospective study of 1656 women in China.

    PubMed

    Zhao, Lei; Lin, Ying; Jiang, Ting-Ting; Wang, Ling; Li, Min; Wang, Ying; Sun, Guo-Qiang; Xiao, Mei

    2017-12-21

    This study aimed to qualify relevant factors for vaginal delivery among women who underwent labor induction with vaginal dinoprostone (PGE2) insert in a Chinese tertiary maternity hospital. A retrospective study was conducted in Hubei Maternal and Child Health Hospital. A total of 1656 pregnancies that underwent labor induction with vaginal dinoprostone insert between January and August 2016 were finally included in this study. Data were analyzed using univariate and multivariable regression modeling. Of 1656 women with PGE2-induced labor at term, 396 (23.91%) gave birth by cesarean section, 1260 (76.09%) had a vaginal delivery among which 921 (55.61%) delivered vaginally within 24 h. Multivariable regression analysis showed that maternal age (p < .001, OR = 0.89, 95%CI 0.85-0.93), parity (multiparous versus nulliparous, p < .001, OR = 8.74, 95%CI 4.36-17.50), baseline fetal heart rate (p = .009, OR = 0.98, 95%CI 0.96-0.99), and birth weight (p < .001, OR = 0.37, 95%CI 0.28-0.51) were significantly correlated with vaginal delivery. Moreover, body mass index (p < .001, OR = 1.11, 95%CI 1.05-1.19), parity (multiparous versus nulliparous, p < .001, OR = 6.57, 95%CI 2.37-18.23), baseline fetal heart rate (p = .004, OR = 0.96, 95%CI 0.94-0.99), and birth weight (p < .001, OR = 0.34, 95%CI 0.21-0.54) were independent predictors of vaginal delivery within 24-h. Our findings suggested a vaginal delivery rate of 76.09% when dinoprostone vaginal insert was used for labor induction, which was markedly higher than the overall annual vaginal delivery rate of 65.1% in China during 2014. Maternal age, parity, baseline fetal heart rate, and birth weight were significant factors for vaginal delivery. This study enables us to better understand the efficiency of dinoprostone and the potential predictors of vaginal delivery in dinoprostone-induced labor, which may be helpful to guide the clinical use of dinoprostone and therefore provide better

  13. Efficacy and safety of iodine-125 radioactive seeds brachytherapy for advanced non-small cell lung cancer-A meta-analysis.

    PubMed

    Zhang, Wenchao; Li, Jiawei; Li, Ran; Zhang, Ying; Han, Mingyong; Ma, Wei

    This meta-analysis was conducted to investigate the efficacy and safety of 125 I brachytherapy for locally advanced non-small cell lung cancer (NSCLC). Trials comparing 125 I brachytherapy with chemotherapy in NSCLC were identified. Meta-analysis was performed to obtain pooled risk ratios for an overall response rate (ORR), disease control rate (DCR) and complications, and pooled hazard ratio for overall survival (OS). Fifteen studies including 1188 cases were included. The pooled result indicated that there were significant differences in ORR, DCR, and OS between 125 I brachytherapy combined with chemotherapy and chemotherapy alone, but no statistic differences in gastrointestinal symptoms, leukopenia, myelosuppression, and hemoglobin reduction. Patients treated with 125 I brachytherapy combined with chemotherapy have a higher relative risk of pneumothorax, bloody sputum, and pneumorrhagia compared with chemotherapy alone. Seeds migration only occurred in the group treated with 125 I brachytherapy. There were significant differences in ORR, DCR, and myelosuppression between 125 I brachytherapy alone and chemotherapy. 125 I brachytherapy combined with chemotherapy can significantly enhance the clinical efficacy and improve the OS of patients with advanced NSCLC without increasing the incidence of complications of chemotherapy. 125 I brachytherapy alone can significantly enhance the clinical efficacy and reduce the incidence of myelosuppression compared with chemotherapy. However, 125 I brachytherapy may cause lung injury. Large sample and higher-quality randomized controlled trials are needed to confirm the pooled results of complications. Copyright © 2017 American Brachytherapy Society. Published by Elsevier Inc. All rights reserved.

  14. Aerobic vaginal pathogens and their sensitivity pattern.

    PubMed

    Mumtaz, Shamim; Ahmad, Mumtaz; Aftab, Irum; Akhtar, Naeem; ul Hassan, Masood; Hamid, Abdul

    2008-01-01

    The vaginal flora is a complicated environment, containing dozens of microbiological species in variable quantities and relative proportions. The frequent cause of vaginal discharge is an infection or colonization with different microorganisms. Some pathologic conditions causing vaginitis are well defined yet, 7-72% of women with vaginitis may remain undiagnosed and such forms of abnormal vaginal flora neither considered as normal, nor can be called bacterial vaginosis have been termed as 'intermediate flora' and its management probably differ from that of bacterial vaginosis. It is of crucial importance in pregnant females at risk of preterm delivery. The present study has been conducted especially to elucidate this type of aerobic vaginal isolates and their culture and sensitivity towards currently used antibiotics. This study was conducted at the Microbiology Department of Fauji Foundation Hospital, Rawalpindi over a period of two years (April 2004-March 2006). One thousand, nine hundred and twenty three high vaginal swabs, both from indoor and outdoor patients were collected, cultured and their susceptibility to various antibiotics was determined. Significant growth was obtained in 731 samples. The highest frequency of infection (39.5%) was observed at 31-40 years followed by 41-50 years (35.8%). About 76% were from outdoor and 24% were from indoor patients. Staphylococcus aureus was the most prevalent vaginal pathogen at 11-60 yrs & with highest prevalence at 31-40 years followed by 41-50 years. It was a predominant pathogen in both indoor (35%) as well as outdoor (41.6%) patients, followed by enteric gram-negative bacilli and other gram-positive cocci. There were very few antibiotics among the conventionally available aminoglycosides, third generation cephalosporins, penicillin, quinolones, sulfonamides and tetracyclines possessing good sensitivity (> 80%) against any one the common aerobic vaginal pathogens. The effective chemotherapeutics agents belong to

  15. 49 CFR 173.316 - Cryogenic liquids in cylinders.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... 49 Transportation 2 2013-10-01 2013-10-01 false Cryogenic liquids in cylinders. 173.316 Section... REQUIREMENTS FOR SHIPMENTS AND PACKAGINGS Gases; Preparation and Packaging § 173.316 Cryogenic liquids in cylinders. (a) General requirements. (1) A cylinder may not be loaded with a cryogenic liquid colder than...

  16. 49 CFR 173.316 - Cryogenic liquids in cylinders.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... 49 Transportation 2 2014-10-01 2014-10-01 false Cryogenic liquids in cylinders. 173.316 Section... REQUIREMENTS FOR SHIPMENTS AND PACKAGINGS Gases; Preparation and Packaging § 173.316 Cryogenic liquids in cylinders. (a) General requirements. (1) A cylinder may not be loaded with a cryogenic liquid colder than...

  17. Turbine endwall single cylinder program

    NASA Technical Reports Server (NTRS)

    Langston, L. S.

    1982-01-01

    Detailed measurement of the flow field in front of a large-scale single cylinder, mounted in a wind tunnel is discussed. A better understanding of the three dimensional separation occuring in front of the cylinder on the endwall, and of the vortex system that is formed is sought. A data base with which to check analytical and numerical computer models of three dimensional flows is also anticipated.

  18. The vaginal microbiota and susceptibility to HIV.

    PubMed

    Buve, Anne; Jespers, Vicky; Crucitti, Tania; Fichorova, Raina N

    2014-10-23

    There is some evidence that the risk of HIV infection per heterosexual act is higher in low-income countries than in high-income countries. We hypothesize that variations in per sex-act transmission probability of HIV may in part be attributed to differences in the composition and function of the vaginal microbiota between different populations. This paper presents data that are in support of this hypothesis. Experimental and clinical studies have provided evidence that the normal vaginal microbiota plays a protective role against acquisition of HIV and other sexually transmitted infections. Epidemiological studies have convincingly shown that disturbances of the vaginal microbiome, namely intermediate flora and bacterial vaginosis, increase the risk of acquisition of HIV infection. A review of the literature found large differences in prevalence of bacterial vaginosis between different populations, with the highest prevalence rates found in black populations. Possible explanations for these differences are presented including data suggesting that there are ethnic differences in the composition of the normal vaginal microbiota. Lastly, interventions are discussed to restore and maintain a healthy vaginal environment. 2014 Wolters Kluwer Health | Lippincott Williams & Wilkins

  19. SU-F-BRA-04: Prostate HDR Brachytherapy with Multichannel Robotic System

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Joseph, F Maria; Podder, T; Yu, Y

    Purpose: High-dose-rate (HDR) brachytherapy is gradually becoming popular in treating patients with prostate cancers. However, placement of the HDR needles at desired locations into the patient is challenging. Application of robotic system may improve the accuracy of the clinical procedure. This experimental study is to evaluate the feasibility of using a multichannel robotic system for prostate HDR brachytherapy. Methods: In this experimental study, the robotic system employed was a 6-DOF Multichannel Image-guided Robotic Assistant for Brachytherapy (MIRAB), which was designed and fabricated for prostate seed implantation. The MIRAB has the provision of rotating 16 needles while inserting them. Ten prostatemore » HDR brachytherapy needles were simultaneously inserted using MIRAB into a commercially available prostate phantom. After inserting the needles into the prostate phantom at desired locations, 2mm thick CT slices were obtained for dosimetric planning. HDR plan was generated using Oncetra planning system with a total prescription dose of 34Gy in 4 fractions. Plan quality was evaluated considering dose coverage to prostate and planning target volume (PTV), with 3mm margin around prostate, as well as the dose limit to the organs at risk (OARs) following the American Brachytherapy Society (ABS) guidelines. Results: From the CT scan, it is observed that the needles were inserted straight into the desired locations and they were adequately spaced and distributed for a clinically acceptable HDR plan. Coverage to PTV and prostate were about 91% (V100= 91%) and 96% (V100=96%), respectively. Dose to 1cc of urethra, rectum, and bladder were within the ABS specified limits. Conclusion: The MIRAB was able to insert multiple needles simultaneously into the prostate precisely. By controlling the MIRAB to insert all the ten utilized needles into the prostate phantom, we could achieve the robotic HDR brachytherapy successfully. Further study for assessing the system

  20. Bacterial vaginosis, aerobic vaginitis, vaginal inflammation and major Pap smear abnormalities.

    PubMed

    Vieira-Baptista, P; Lima-Silva, J; Pinto, C; Saldanha, C; Beires, J; Martinez-de-Oliveira, J; Donders, G

    2016-04-01

    The purpose of this investigation was to evaluate the impact of the vaginal milieu on the presence of abnormal Pap smears and a positive human papilloma virus (HPV) test. A cross-sectional study was conducted between June 2014 and May 2015, evaluating the vaginal discharge by fresh wet mount microscopy and comparing these data with Pap smear findings. Wet mount slides were scored for bacterial vaginosis (BV), aerobic vaginitis (AV), presence of Candida and Trichomonas vaginalis. Cytologic evaluation was done on all Pap smears according to the Bethesda criteria. The cobas© HPV Test (Roche) was performed for HPV detection. A total of 622 cases were evaluated. The mean age of the patients was 41.6 ± 10.65 years (range 21-75). Eighty-three women (13.3 %) had a cytology result worse than low-grade squamous intraepithelial lesion (LSIL). When comparing this group with the one with normal or minor [atypical squamous cells of undetermined significance (ASC-US) or LSIL] Pap smear abnormalities, there were no differences in the presence of Candida (32.5 % vs. 33.2 %, p = 1.0), absence of lactobacilli (38.6 % vs. 32.5 %, p = 0.32) or BV (20.5 % vs. 13.2 %, p = 0.09). On the other hand, moderate or severe inflammation (msI) (41.0 % vs. 28.8 %, p = 0,04), moderate or severe AV (msAV) (16.9 % vs. 7.2 %, p = 0.009) and msAV/BV (37.3 % vs. 20.0 %, p = 0.001) were more common in women with such major cervical abnormalities. No significant association was found between deviations of the vaginal milieu and high-risk HPV infection. The presence of msI or msAV, but not BV, is independently associated with an increased risk of major cervical cytological abnormalities, but not with HPV infection.

  1. Acceptability of the vaginal contraceptive ring among adolescent women.

    PubMed

    Terrell, Lekeisha R; Tanner, Amanda E; Hensel, Devon J; Blythe, Margaret J; Fortenberry, J Dennis

    2011-08-01

    Although underutilized, the vaginal contraceptive ring has several advantages over other contraceptive methods that could benefit adolescents. We examined factors that may influence willingness to try the vaginal ring including: sexual and contraceptive history, genital comfort, and vaginal ring characteristics. Cross sectional Midwestern adolescent health clinics Adolescent women (N = 200; 14-18 years; 89% African-American) INTERVENTIONS/MAIN OUTCOME MEASURES: All participants received education about the vaginal ring and viewed pictures demonstrating insertion; they then completed a visual/audio computer-assisted self interview. The primary outcome variable, willingness to try the vaginal ring, was a single Likert-scale item. Over half the participants reported knowledge of the vaginal ring with healthcare providers identified as the most important source of contraceptive information. Comfort with one's genitals, insertion and removal, using alternative methods of insertion, and knowing positive method characteristics were significantly associated with willingness to try the vaginal ring. A decreased willingness to try the vaginal ring was related to concerns of the ring getting lost inside or falling out of the vagina. Willingness to try the ring was associated with positive feelings about genitals (e.g., comfort with appearance, hygiene, function). Thus, to increase willingness to try the vaginal ring among adolescents, providers should make it common practice to discuss basic female reproductive anatomy, raise awareness about female genital health and address concerns about their genitals. Providers can offer alternative insertion techniques (e.g., gloves) to make use more accessible. These strategies may increase vaginal ring use among adolescents. 2011 North American Society for Pediatric and Adolescent Gynecology. Published by Elsevier Inc. All rights reserved.

  2. 78 FR 41125 - Interim Enforcement Policy for Permanent Implant Brachytherapy Medical Event Reporting

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-07-09

    ... Brachytherapy Medical Event Reporting AGENCY: Nuclear Regulatory Commission. ACTION: Policy statement; revision... medical events occurring under an NRC licensee's permanent implant brachytherapy program. This interim..., ``Adequacy of Medical Event Definitions in 10 CFR [Title 10 of the Code of Federal Regulations] 35.3045, and...

  3. 49 CFR 176.92 - Cylinders laden in vehicles.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... 49 Transportation 2 2014-10-01 2014-10-01 false Cylinders laden in vehicles. 176.92 Section 176.92... Requirements for Transport Vehicles Loaded With Hazardous Materials and Transported on Board Ferry Vessels § 176.92 Cylinders laden in vehicles. Any cylinder of Class 2 (compressed gas) material which is...

  4. 49 CFR 176.92 - Cylinders laden in vehicles.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 49 Transportation 2 2010-10-01 2010-10-01 false Cylinders laden in vehicles. 176.92 Section 176.92... Requirements for Transport Vehicles Loaded With Hazardous Materials and Transported on Board Ferry Vessels § 176.92 Cylinders laden in vehicles. Any cylinder of Class 2 (compressed gas) material which is...

  5. 49 CFR 176.92 - Cylinders laden in vehicles.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... 49 Transportation 2 2013-10-01 2013-10-01 false Cylinders laden in vehicles. 176.92 Section 176.92... Requirements for Transport Vehicles Loaded With Hazardous Materials and Transported on Board Ferry Vessels § 176.92 Cylinders laden in vehicles. Any cylinder of Class 2 (compressed gas) material which is...

  6. 49 CFR 176.92 - Cylinders laden in vehicles.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... 49 Transportation 2 2012-10-01 2012-10-01 false Cylinders laden in vehicles. 176.92 Section 176.92... Requirements for Transport Vehicles Loaded With Hazardous Materials and Transported on Board Ferry Vessels § 176.92 Cylinders laden in vehicles. Any cylinder of Class 2 (compressed gas) material which is...

  7. Vaginal foreign body presenting as bleeding with defecation in a child.

    PubMed

    Abdessamad, Hasan M; Greenfield, Marjorie

    2009-04-01

    Symptoms secondary to a vaginal foreign body are responsible for approximately 4% of pediatric gynecologic outpatient visits.(1) The classic symptom is vaginal bleeding, but vaginal discharge, foul odor, irritation, abdominal pain, and hematuria have been described. We are reporting a case of a microscopic vaginal foreign body presenting as hematochezia in a preadolescent girl. This case is unique in that the patient presented with bleeding with defecation, without vaginal bleeding. Vaginal foreign bodies can present with diverse symptomatology. Physicians should consider the diagnosis of vaginal foreign body when presented with a young female patient with unexplained hematochezia.

  8. Current situation of high-dose-rate brachytherapy for cervical cancer in Brazil*

    PubMed Central

    da Silva, Rogério Matias Vidal; Pinezi, Juliana Castro Dourado; Macedo, Luiz Eduardo Andrade; Souza, Divanízia do Nascimento

    2014-01-01

    Objective To assess the current situation of high-dose-rate (HDR) brachytherapy for cancer of the cervix in Brazil, regarding apparatuses, planning methods, prescription, fractionation schedule and evaluation of dose in organs at risk. Materials and Methods In the period between March/2012 and May/2013, a multiple choice questionnaire was developed and sent to 89 Brazilian hospitals which perform HDR brachytherapy. Results Sixty-one services answered the questionnaire. All regions of the country experienced a sharp increase in the number of HDR brachytherapy services in the period from 2001 to 2013. As regards planning, although a three-dimensional planning software was available in 91% of the centers, conventional radiography was mentioned by 92% of the respondents as their routine imaging method for such a purpose. Approximately 35% of respondents said that brachytherapy sessions are performed after teletherapy. The scheme of four 7 Gy intracavitary insertions was mentioned as the most frequently practiced. Conclusion The authors observed that professionals have difficulty accessing adjuvant three-dimensional planning tools such as computed tomography and magnetic resonance imaging. PMID:25741073

  9. Vaginal surgery for pelvic organ prolapse using mesh and a vaginal support device.

    PubMed

    Carey, M; Slack, M; Higgs, P; Wynn-Williams, M; Cornish, A

    2008-02-01

    To describe a new surgical procedure for pelvic organ prolapse using mesh and a vaginal support device (VSD) and to report the results of surgery. A prospective observational study. Two tertiary referral Urogynaecology practices. Ninety-five women with International Continence Society pelvic organ prolapse quantification stage 2 or more pelvic organ prolapse who underwent vaginal surgery using mesh augmentation and a VSD. Surgery involved a vaginal approach with mesh reinforcement and placement of a VSD for 4 weeks. At 6 and 12 months, women were examined for prolapse recurrence, and visual analogue scales for satisfaction were completed. Women completed quality-of-life (QOL) questionnaires preoperatively and at 6 and 12 months. Objective success of surgery at 6 and 12 months following surgery. Secondary outcomes were subjective success, complications, QOL outcomes and patients' satisfaction. Objective success rate was 92 and 85% at 6 and 12 months, respectively. Subjective success rate was 91 and 87% at 6 and 12 months, respectively. New prolapse in nonrepaired compartments accounted for 7 of 12 (58%) failures at 12 months. Two of 4 mesh exposures required surgery. Sexual dysfunction was reported by 58% of sexually active women preoperatively and 23% at 12 months. QOL scores significantly improved at 12 months compared with baseline (P < 0.0001). Vaginal surgery using mesh and a VSD is an effective procedure for pelvic organ prolapse. However, further studies are required to establish the role of the surgery described in this study.

  10. Mucoadhesive and thermogelling systems for vaginal drug delivery.

    PubMed

    Caramella, Carla M; Rossi, Silvia; Ferrari, Franca; Bonferoni, Maria Cristina; Sandri, Giuseppina

    2015-09-15

    This review focuses on two formulation approaches, mucoadhesion and thermogelling, intended for prolonging residence time on vaginal mucosa of medical devices or drug delivery systems, thus improving their efficacy. The review, after a brief description of the vaginal environment and, in particular, of the vaginal secretions that strongly affect in vivo performance of vaginal formulations, deals with the above delivery systems. As for mucoadhesive systems, conventional formulations (gels, tablets, suppositories and emulsions) and novel drug delivery systems (micro-, nano-particles) intended for vaginal administration to achieve either local or systemic effect are reviewed. As for thermogelling systems, poly(ethylene oxide-propylene oxide-ethylene oxide) copolymer-based and chitosan-based formulations are discussed as thermogelling systems. The methods employed for functional characterization of both mucoadhesive and thermogelling drug delivery systems are also briefly described. Copyright © 2015 Elsevier B.V. All rights reserved.

  11. Vaginal rhinosporidiosis: a case report.

    PubMed

    Jahan, S; Haque, M A; Nessa, F; Begum, A; Hasan, A H; Sen, S; Huq, M H

    2014-07-01

    The female genital tract is an extremely rare site for Rhinosporidiosis. Here we described a 13 year old girl who presented with a slow growing polypoid fleshy mass in the posterior vaginal wall near the orifice for 6 months with scanty bleeding from the mass. The girl was admitted to hospital with profuse watery vaginal discharge. Excision of the mass was followed by histopathological examination which confirmed the diagnosis Rhinosporidiosis.

  12. Twin vaginal delivery: innovate or abdicate.

    PubMed

    Easter, Sarah Rae; Taouk, Laura; Schulkin, Jay; Robinson, Julian N

    2017-05-01

    Neonatal safety data along with national guidelines have prompted renewed interest in vaginal delivery of twins, particularly in the case of the noncephalic second twin. Yet, the rising rate of twin cesarean deliveries, coupled with the national decline in operative obstetrics, raises concerns about the availability of providers who are skilled in twin vaginal birth. Providers are key stakeholders for increasing rates of twin vaginal delivery. We surveyed a group of practicing obstetricians to explore potential barriers to the vaginal birth of twins with a focus on delivery of the noncephalic second twin. Among 107 responding providers, only 57% would deliver a noncephalic second twin by breech extraction. Providers who preferred breech extraction had a higher rate of maternal-fetal medicine subspecialty training (26.2% vs 4.3%; P<.01) and were more likely to be in an academic practice environment (36.1% vs 10.9%; P<.01) and to practice in high-volume centers that deliver >30 sets of twins annually (57.4% vs 34.8%; P=.02). Most providers (54.2%) were familiar with the findings from the recent randomized trial that demonstrated the safety of twin vaginal birth. However, knowledge of the trial was not associated statistically with a preference for breech extraction (62.3% vs 43.5%; P=.05). Providers who preferred breech extraction were more likely to agree with recent society guidelines that encourage the vaginal birth of twins (86.9% vs 63.0%; P<.01). In an adjusted analysis, the 46% of providers with a perceived need for more training were far less likely to prefer breech extraction for delivery of a noncephalic second twin (adjusted odds ratio, 0.38; 95% confidence interval, 0.16-0.95). Furthermore, 57% of providers who would not offer their patient breech extraction would be willing to consult a colleague for support with a noncephalic twin delivery. These results suggest that scientific evidence and society opinion are likely insufficient to reverse the national

  13. Interactive multiobjective optimization for anatomy-based three-dimensional HDR brachytherapy

    NASA Astrophysics Data System (ADS)

    Ruotsalainen, Henri; Miettinen, Kaisa; Palmgren, Jan-Erik; Lahtinen, Tapani

    2010-08-01

    In this paper, we present an anatomy-based three-dimensional dose optimization approach for HDR brachytherapy using interactive multiobjective optimization (IMOO). In brachytherapy, the goals are to irradiate a tumor without causing damage to healthy tissue. These goals are often conflicting, i.e. when one target is optimized the other will suffer, and the solution is a compromise between them. IMOO is capable of handling multiple and strongly conflicting objectives in a convenient way. With the IMOO approach, a treatment planner's knowledge is used to direct the optimization process. Thus, the weaknesses of widely used optimization techniques (e.g. defining weights, computational burden and trial-and-error planning) can be avoided, planning times can be shortened and the number of solutions to be calculated is small. Further, plan quality can be improved by finding advantageous trade-offs between the solutions. In addition, our approach offers an easy way to navigate among the obtained Pareto optimal solutions (i.e. different treatment plans). When considering a simulation model of clinical 3D HDR brachytherapy, the number of variables is significantly smaller compared to IMRT, for example. Thus, when solving the model, the CPU time is relatively short. This makes it possible to exploit IMOO to solve a 3D HDR brachytherapy optimization problem. To demonstrate the advantages of IMOO, two clinical examples of optimizing a gynecologic cervix cancer treatment plan are presented.

  14. Photoacoustic imaging of prostate brachytherapy seeds with transurethral light delivery

    NASA Astrophysics Data System (ADS)

    Lediju Bell, Muyinatu A.; Guo, Xiaoyu; Song, Danny Y.; Boctor, Emad M.

    2014-03-01

    We present a novel approach to photoacoustic imaging of prostate brachytherapy seeds utilizing an existing urinary catheter for transurethral light delivery. Two canine prostates were surgically implanted with brachyther- apy seeds under transrectal ultrasound guidance. One prostate was excised shortly after euthanasia and fixed in gelatin. The second prostate was imaged in the native tissue environment shortly after euthanasia. A urinary catheter was inserted in the urethra of each prostate. A 1-mm core diameter optical fiber coupled to a 1064 nm Nd:YAG laser was inserted into the urinary catheter. Light from the fiber was either directed mostly parallel to the fiber axis (i.e. end-fire fire) or mostly 90° to the fiber axis (i.e. side-fire fiber). An Ultrasonix SonixTouch scanner, transrectal ultrasound probe with curvilinear (BPC8-4) and linear (BPL9-5) arrays, and DAQ unit were utilized for synchronized laser light emission and photoacoustic signal acquisition. The implanted brachytherapy seeds were visualized at radial distances of 6-16 mm from the catheter. Multiple brachytherapy seeds were si- multaneously visualized with each array of the transrectal probe using both delay-and-sum (DAS) and short-lag spatial coherence (SLSC) beamforming. This work is the first to demonstrate the feasibility of photoacoustic imaging of prostate brachytherapy seeds using a transurethral light delivery method.

  15. The vaginal microbiota, host defence and reproductive physiology.

    PubMed

    Smith, Steven B; Ravel, Jacques

    2017-01-15

    The interaction between the human host and the vaginal microbiota is highly dynamic. Major changes in the vaginal physiology and microbiota over a woman's lifetime are largely shaped by transitional periods such as puberty, menopause and pregnancy, while daily fluctuations in microbial composition observed through culture-independent studies are more likely to be the results of daily life activities and behaviours. The vaginal microbiota of reproductive-aged women is largely made up of at least five different community state types. Four of these community state types are dominated by lactic-acid producing Lactobacillus spp. while the fifth is commonly composed of anaerobes and strict anaerobes and is sometimes associated with vaginal symptoms. The production of lactic acid has been associated with contributing to the overall health of the vagina due to its direct and indirect effects on pathogens and host defence. Some species associated with non-Lactobacillus vaginal microbiota may trigger immune responses as well as degrade the host mucosa, processes that ultimately increase susceptibility to infections and contribute to negative reproductive outcomes such as infertility and preterm birth. Further studies are needed to better understand the functional underpinnings of how the vaginal microbiota affect host physiology but also how host physiology affects the vaginal microbiota. Understanding this fine-tuned interaction is key to maintaining women's reproductive health. © 2016 The Authors. The Journal of Physiology © 2016 The Physiological Society.

  16. The vaginal microbiota, host defence and reproductive physiology

    PubMed Central

    Smith, Steven B

    2016-01-01

    Abstract The interaction between the human host and the vaginal microbiota is highly dynamic. Major changes in the vaginal physiology and microbiota over a woman's lifetime are largely shaped by transitional periods such as puberty, menopause and pregnancy, while daily fluctuations in microbial composition observed through culture‐independent studies are more likely to be the results of daily life activities and behaviours. The vaginal microbiota of reproductive‐aged women is largely made up of at least five different community state types. Four of these community state types are dominated by lactic‐acid producing Lactobacillus spp. while the fifth is commonly composed of anaerobes and strict anaerobes and is sometimes associated with vaginal symptoms. The production of lactic acid has been associated with contributing to the overall health of the vagina due to its direct and indirect effects on pathogens and host defence. Some species associated with non‐Lactobacillus vaginal microbiota may trigger immune responses as well as degrade the host mucosa, processes that ultimately increase susceptibility to infections and contribute to negative reproductive outcomes such as infertility and preterm birth. Further studies are needed to better understand the functional underpinnings of how the vaginal microbiota affect host physiology but also how host physiology affects the vaginal microbiota. Understanding this fine‐tuned interaction is key to maintaining women's reproductive health. PMID:27373840

  17. Endovascular Management of Intractable Postpartum Hemorrhage Caused by Vaginal Laceration

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Koganemaru, Masamichi, E-mail: mkoganemaru@med.kurume-u.ac.jp; Nonoshita, Masaaki, E-mail: z2rs-1973@yahoo.co.jp; Iwamoto, Ryoji, E-mail: iwamoto-ryouji@kurume-u.ac.jp

    PurposeWe evaluated the management of transcatheter arterial embolization for postpartum hemorrhage caused by vaginal laceration.Materials and MethodsWe reviewed seven cases of patients (mean age 30.9 years; range 27–35) with intractable hemorrhages and pelvic hematomas caused by vaginal lacerations, who underwent superselective transcatheter arterial embolization from January 2008 to July 2014. Postpartum hemorrhage was evaluated by angiographic vascular mapping to determine the vaginal artery’s architecture, technical and clinical success rates, and complications.ResultsThe vaginal artery was confirmed as the source of bleeding in all cases. The artery was found to originate from the uterine artery in three cases, the uterine and obturator arteriesmore » in two, or the internal pudendal artery in two. After vaginal artery embolization, persistent contrast extravasation from the inferior mesenteric artery as an anastomotic branch was noted in one patient. Nontarget vessels (the inferior vesical artery and nonbleeding vaginal arterial branches) were embolized in one patient. Effective control of hemostasis and no post-procedural complications were confirmed for all cases.ConclusionPostpartum hemorrhages caused by vaginal lacerations involve the vaginal artery arising from the anterior trunk of the internal iliac artery with various branching patterns. Superselective vaginal artery embolization is clinically acceptable for the successful treatment of vaginal laceration hemorrhages, with no complications. After vaginal artery embolization, it is suggested to check for the presence of other possible bleeding vessels by pelvic aortography with a catheter tip at the L3 vertebral level, and to perform a follow-up assessment.« less

  18. PIV measurements of airflow past multiple cylinders

    NASA Astrophysics Data System (ADS)

    Wodziak, Waldemar; Sobczyk, Jacek

    2018-06-01

    Flow characteristics in vicinity of six circular cylinders aligned inline was investigated experimentally by means of PIV method. Experiments were conducted in a low speed closed circuit wind tunnel. Inflow velocity was 1.2 m/s which corresponds to Re=1600 based on the cylinder diameter. Spacing ratio between cylinders L/D was 1.5. Instantaneous and averaged velocity fields were presented. Experiments were designed in order to use their results as a test case for future numerical calculations.

  19. 21 CFR 529.1003 - Flurogestone acetate-impregnated vaginal sponge.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 21 Food and Drugs 6 2010-04-01 2010-04-01 false Flurogestone acetate-impregnated vaginal sponge... § 529.1003 Flurogestone acetate-impregnated vaginal sponge. (a) Specifications. Each vaginal sponge... ewes during their normal breeding season. (2) Limitations. Using applicator provided, insert sponge...

  20. Optical clearing of vaginal tissues

    NASA Astrophysics Data System (ADS)

    Chang, Chun-Hung; Myers, Erinn M.; Kennelly, Michael J.; Fried, Nathaniel M.

    2017-02-01

    Near-IR laser energy in conjunction with applied tissue cooling is being investigated for thermal remodeling of endopelvic fascia during minimally invasive treatment of female stress urinary incontinence. Previous simulations of light transport, heat transfer, and tissue thermal damage have shown that a transvaginal approach is more feasible than a transurethral approach. However, undesirable thermal insult to vaginal wall was predicted. This study explores whether an optical clearing agent (OCA) can improve optical penetration depth and completely preserve vaginal wall during subsurface treatment of endopelvic fascia. Several OCA mixtures were tested, and 100% glycerol was found to be optimal. Optical transmission studies, optical coherence tomography, reflection spectroscopy, and computer simulations of thermal damage to tissue using glycerol were performed. The OCA produced a 61% increase in optical transmission through porcine vaginal wall at 37 °C after 30 min. Monte Carlo (MC) light transport, heat transfer, and Arrhenius integral thermal damage simulations were performed. MC model showed improved energy deposition in endopelvic fascia using OCA. Without OCA, 62, 37, and 1% of energy was deposited in vaginal wall, endopelvic fascia, and urethral wall, compared with 50, 49, and 1% with OCA. Use of OCA also yielded 0.5 mm increase in treatment depth, allowing potential thermal tissue remodeling at 3 mm depth.

  1. Relationship between lactobacilli and opportunistic bacterial pathogens associated with vaginitis.

    PubMed

    Razzak, Mohammad Sabri A; Al-Charrakh, Alaa H; Al-Greitty, Bara Hamid

    2011-04-01

    Vaginitis, is an infectious inflammation of the vaginal mucosa, which sometimes involves the vulva. The balance of the vaginal flora is maintained by the Lactobacilli and its protective and probiotic role in treating and preventing vaginal infection by producing antagonizing compounds which are regarded as safe for humans. The aim of this study was to evaluate the protective role of Lactobacilli against common bacterial opportunistic pathogens in vaginitis and study the effects of some antibiotics on Lactobacilli isolates. In this study (110) vaginal swabs were obtained from women suffering from vaginitis who admitted to Babylon Hospital of Maternity and Paediatrics in Babylon province, Iraq. The study involved the role of intrauterine device among married women with vaginitis and also involved isolation of opportunistic bacterial isolates among pregnant and non pregnant women. This study also involved studying probiotic role of Lactobacilli by production of some defense factors like hydrogen peroxide, bacteriocin, and lactic acid. Results revealed that a total of 130 bacterial isolates were obtained. Intrauterine device was a predisposing factor for vaginitis. The most common opportunistic bacterial isolates were Staphylococcus aureus, Escherichia coli, Streptococcus agalactiae, and Klebsiella pneumoniae. All Lactobacilli were hydrogen peroxide producers while some isolates were bacteriocin producers that inhibited some of opportunistic pathogens (S. aureus, E. coli). Lactobacilli were sensitive to erythromycin while 93.3% of them were resistant to ciprofloxacin and (40%, 53.3%) of them were resistant to amoxicillin and gentamycin respectively. Results revealed that there was an inverse relationship between Lactobacilli presence and organisms causing vaginitis. This may be attributed to the production of defense factors by Lactobacilli. The types of antibiotics used to treat vaginitis must be very selective in order not to kill the beneficial bacteria

  2. Relationship between lactobacilli and opportunistic bacterial pathogens associated with vaginitis

    PubMed Central

    Razzak, Mohammad Sabri A.; Al-Charrakh, Alaa H.; AL-Greitty, Bara Hamid

    2011-01-01

    Background: Vaginitis, is an infectious inflammation of the vaginal mucosa, which sometimes involves the vulva. The balance of the vaginal flora is maintained by the Lactobacilli and its protective and probiotic role in treating and preventing vaginal infection by producing antagonizing compounds which are regarded as safe for humans. Aim: The aim of this study was to evaluate the protective role of Lactobacilli against common bacterial opportunistic pathogens in vaginitis and study the effects of some antibiotics on Lactobacilli isolates. Materials and Methods: In this study (110) vaginal swabs were obtained from women suffering from vaginitis who admitted to Babylon Hospital of Maternity and Paediatrics in Babylon province, Iraq. The study involved the role of intrauterine device among married women with vaginitis and also involved isolation of opportunistic bacterial isolates among pregnant and non pregnant women. This study also involved studying probiotic role of Lactobacilli by production of some defense factors like hydrogen peroxide, bacteriocin, and lactic acid. Results: Results revealed that a total of 130 bacterial isolates were obtained. Intrauterine device was a predisposing factor for vaginitis. The most common opportunistic bacterial isolates were Staphylococcus aureus, Escherichia coli, Streptococcus agalactiae, and Klebsiella pneumoniae. All Lactobacilli were hydrogen peroxide producers while some isolates were bacteriocin producers that inhibited some of opportunistic pathogens (S. aureus, E. coli). Lactobacilli were sensitive to erythromycin while 93.3% of them were resistant to ciprofloxacin and (40%, 53.3%) of them were resistant to amoxicillin and gentamycin respectively. Results revealed that there was an inverse relationship between Lactobacilli presence and organisms causing vaginitis. This may be attributed to the production of defense factors by Lactobacilli. Conclusion: The types of antibiotics used to treat vaginitis must be very

  3. An unusual cause of vaginal discharge following gender reassignment.

    PubMed

    Sukumaran, S; Moran, P A; Makar, A

    2009-02-01

    Neovaginal reconstruction is an important part of gender reassignment surgery. We report a case of stone formation at the apex of vaginal vault constructed with sigmoid colon segment. A 48-year-old woman presented with profuse vaginal discharge for 1 year. She had a history of gender reassignment surgery (male to female) in 1994, and the neovagina had been constructed with an isolated sigmoid colon. Vaginoscopy performed using a cystoscope revealed multiple calculi at the vaginal vault on the endoscopic gastrointestinal anastomosis staples that had been used to close the vault. Colon-vaginoplasty has the advantages of providing adequate lubrication, but excessive vaginal discharge could be a problem, as colon is a mucous membrane. Stone formation in the vaginal vault should be considered in cases of gender reassignment with persistent vaginal discharge. This case also highlights the use of cystoscope in visualising the upper vagina in difficult circumstances.

  4. Acoustics and Surface Pressure Measurements from Tandem Cylinder Configurations

    NASA Technical Reports Server (NTRS)

    Hutcheson, Florence V.; Brooks, Thomas F.; Lockard, David P.; Choudhari, Meelan M.; Stead, Daniel J.

    2014-01-01

    Acoustic and unsteady surface pressure measurements from two cylinders in tandem configurations were acquired to study the effect of spacing, surface trip and freestream velocity on the radiated noise. The Reynolds number ranged from 1.15x10(exp 5) to 2.17x10(exp 5), and the cylinder spacing varied between 1.435 and 3.7 cylinder diameters. The acoustic and surface pressure spectral characteristics associated with the different flow regimes produced by the cylinders' wake interference were identified. The dependence of the Strouhal number, peak Sound Pressure Level and spanwise coherence on cylinder spacing and flow velocity was examined. Directivity measurements were performed to determine how well the dipole assumption for the radiation of vortex shedding noise holds for the largest and smallest cylinder spacing tested.

  5. 21 CFR 884.3900 - Vaginal stent.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Vaginal stent. 884.3900 Section 884.3900 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES... stent. (a) Identification. A vaginal stent is a device used to enlarge the vagina by stretching, or to...

  6. The Cylinder and Semicylinder in Subsonic Flow

    NASA Technical Reports Server (NTRS)

    Bingham, Harry J.; Weimer, David K..; Griffith, Wayland

    1952-01-01

    In studying the diffraction of shock waves around various two-dimensional obstacles we have observed that flow separation and the formation of vortices contributes in an important way to transient loading of the obstacle. The cases of a cylinder and semicylinder are especially interesting because the breakaway point is not clearly defined as it is for objects having sharp corners. Accordingly a number of experiments have been made in the shock tube to observe the influence of Reynolds number and Mach number on the transient flow patterns about a cylinder and about a semicylinder mounted on a smooth plane. Some differences might be anticipated since the plane would impose a symmetry on the flow and produce a viscous boundary layer for which there is no counterpart with the cylinder. In the course of these experiments it was noted that a condition of steady subsonic flow about both the cylinder and semicylinder was approached. Thus a comparison with von Karrnan's theoretical calculation of the drag on a cylinder, from certain characteristics of its wake or "vortex street", was undertaken.

  7. Local Production of Chemokines during Experimental Vaginal Candidiasis

    PubMed Central

    Saavedra, Michael; Taylor, Brad; Lukacs, Nicholas; Fidel, Paul L.

    1999-01-01

    Recurrent vulvovaginal candidiasis, caused by Candida albicans, is a significant problem in women of childbearing age. Although cell-mediated immunity (CMI) due to T cells and cytokines is the predominant host defense mechanism against C. albicans at mucosal tissue sites, host defense mechanisms against C. albicans at the vaginal mucosa are poorly understood. Based on an estrogen-dependent murine model of vaginal candidiasis, our data suggest that systemic CMI is ineffective against C. albicans vaginal infections. Thus, we have postulated that local immune mechanisms are critical for protection against infection. In the present study, the kinetic production of chemokines normally associated with the chemotaxis of T cells, macrophages (RANTES, MIP-1α, MCP-1), and polymorphonuclear neutrophils (MIP-2) was examined following intravaginal inoculation of C. albicans in estrogen-treated or untreated mice. Results showed significant increases in MCP-1 protein and mRNA in vaginal tissue of infected mice as early as 2 and 4 days postinoculation, respectively, that continued through a 21-day observation period, irrespective of estrogen status. No significant changes were observed with RANTES, MIP-1α, or MIP-2, although relatively high constitutive levels of RANTES mRNA and MIP-2 protein were observed. Furthermore, intravaginal immunoneutralization of MCP-1 with anti-MCP-1 antibodies resulted in a significant increase in vaginal fungal burden early during infection, suggesting that MCP-1 plays some role in reducing the fungal burden during vaginal infection. However, the lack of changes in leukocyte profiles in vaginal lavage fluids collected from infected versus uninfected mice suggests that MCP-1 functions to control vaginal C. albicans titers in a manner independent of cellular chemotactic activity. PMID:10531235

  8. Vaginal Gene Expression During Treatment With Aromatase Inhibitors.

    PubMed

    Kallak, Theodora Kunovac; Baumgart, Juliane; Nilsson, Kerstin; Åkerud, Helena; Poromaa, Inger Sundström; Stavreus-Evers, Anneli

    2015-12-01

    Aromatase inhibitor (AI) treatment suppresses estrogen biosynthesis and causes genitourinary symptoms of menopause such as vaginal symptoms, ultimately affecting the quality of life for many postmenopausal women with breast cancer. Thus, the aim of this study was to examine vaginal gene expression in women during treatment with AIs compared with estrogen-treated women. The secondary aim was to study the presence and localization of vaginal aromatase. Vaginal biopsies were collected from postmenopausal women treated with AIs and from age-matched control women treated with vaginal estrogen therapy. Differential gene expression was studied with the Affymetrix Gene Chip Gene 1.0 ST Array (Affymetrix Inc, Santa Clara, CA) system, Ingenuity pathway analysis, quantitative real-time polymerase chain reaction, and immunohistochemistry. The expression of 279 genes differed between the 2 groups; AI-treated women had low expression of genes involved in cell differentiation, proliferation, and cell adhesion. Some differentially expressed genes were found to interact indirectly with the estrogen receptor alpha. In addition, aromatase protein staining was evident in the basal and the intermediate vaginal epithelium layers, and also in stromal cells with a slightly stronger staining intensity found in AI-treated women. In this study, we demonstrated that genes involved in cell differentiation, proliferation, and cell adhesion are differentially expressed in AI-treated women. The expression of vaginal aromatase suggests that this could be the result of local and systemic inhibition of aromatase. Our results emphasize the role of estrogen for vaginal cell differentiation and proliferation and future drug candidates should be aimed at improving cell differentiation and proliferation. Copyright © 2015 Elsevier Inc. All rights reserved.

  9. Causes and Diagnosis of Abnormal Vaginal Bleeding.

    PubMed

    Sokol, Elizabeth; Peddinti, Radhika

    2015-07-01

    Abnormal vaginal bleeding in a postmenarchal adolescent patient is most often related to dysfunctional uterine bleeding. However, there are other potential etiologies, including hematologic disorders, infections, and oncologic problems. We present a 12-year-old girl who presented with prolonged vaginal bleeding and was ultimately diagnosed with rhabdomyosarcoma. In this article, we discuss the approach to a patient with vaginal bleeding along with a more in-depth review of risk stratification in rhabdomyosarcoma, including treatment options such as chemotherapy, surgery, and radiation therapy. Copyright 2015, SLACK Incorporated.

  10. Douching with Water Works device for perceived vaginal odor with or without complaints of discharge in women with no infectious cause of vaginitis: a pilot study.

    PubMed

    Chatwani, Ashwin J; Hassan, Sarmina; Rahimi, Salma; Jeronis, Stacey; Dandolu, Vani

    2006-01-01

    To determine if douching with Water Works device for 1 month can (1) lower or eliminate perceived vaginal odor by subject; (2) have any effects on vaginal ecosystem. Ten women with perceived vaginal odor with or without discharge, douched every day for 4 weeks in an open-label, nonrandomized pilot study. Primary outcome measures included perceived vaginal odor by subject, lactobacilli score from Nugent slide, and acceptance of the Water Works douching system. Secondary outcome included the safety of using this douching device. At week 4, there was improvement in vaginal odor (P=.0006) and there was no significant change in lactobacilli score. Douching with Water Works device is associated with reduction or elimination of vaginal odor without adversely affecting the vaginal ecosystem.

  11. Water entry and exit of horizontal circular cylinders

    NASA Astrophysics Data System (ADS)

    Greenhow, M.; Moyo, S.

    This paper describes fully nonlinear two-dimensional numerical calculations of the free-surface deformations of initially calm water caused by the forced motion of totally or partially submerged horizontal circular cylinders. The paper considers the following. (i) Totally submerged cylinders moving with constant velocity in vertical, horizontal or combined motions. Results are compared with the small-time asymptotic solution obtained by Tyvand and Milohin 1995. Their results, which are taken to third-order (which is when gravity terms first appear in the expansions), are in excellent agreement with the numerical calculations for small times; beyond this only the numerical method gives accurate results until the free surface breaks or the cylinder emerges from the free surface. Breaking can occur during exit due to strongly negative pressures arising on the cylinder surface, or during the downwards motion causing a free-surface depression which closes up rapidly, forming splashes. Downwards motion is also shown to give rise to high-frequency waves in some cases. (ii) The free-surface deformations, pressures and forces acting on a cylinder in vertical or oblique forced motion during engulfment when it submerges from being initially half-submerged. The initial stages, when the cylinder still pierces the free surface, specify the initial conditions for a separate program for a completely submerged body, thereby allowing complete engulfment to be studied. The free surface closes up violently over the top of the cylinder resulting in jet flow, which, while difficult to handle numerically, has been shown to be insignificant for the bulk flow and the cylinder pressures and forces.

  12. Rectorrhagia and vaginal discharge caused by a vaginal foreign body--a case report and review of literature.

    PubMed

    Shiryazdi, S M; Heiranizadeh, N; Soltani, H R

    2013-06-01

    An 8-year-old girl was taken to an outpatient clinic of surgery suffering from rectorrhagia and purulent, smelly vaginal discharge. Colonoscopy and biopsy were done before referring and sulfasalazine regime was administrated for probable colitis. The surgeon performed a rigid rectosigmoidoscopy under general anesthesia and no positive evidence was found. Having examined the hymen, it was found to be intact but a purulent discharge was observed. After drying the discharge, a black foreign body was seen in the bottom of the vagina and brought out by a fine forceps. It was a toy's wheel. The patient and her mother both denied foreign body abusing history. It was recommended she go for a psychological consultation. Generally speaking, all young patients suffering from vaginal or rectal bleeding with or without discharge should have their vagina checked for a foreign body. What is recommended in such cases is to undergo sonography or plain radiography before considering invasive or non-invasive procedures for evaluating anal and sigmoid abnormalities. Last but not least, a vaginal irrigation, precise examination of hymen, and posterior fossa can prove very useful for detecting simple vaginal bodies that can lead to various vaginal, rectal and abdominal complications. Copyright © 2013 North American Society for Pediatric and Adolescent Gynecology. Published by Elsevier Inc. All rights reserved.

  13. Characterization of Low-Energy Photon-Emitting Brachytherapy Sources with Modified Strengths for Applications in Focal Therapy

    NASA Astrophysics Data System (ADS)

    Reed, Joshua L.

    Permanent implants of low-energy photon-emitting brachytherapy sources are used to treat a variety of cancers. Individual source models must be separately characterized due to their unique geometry, materials, and radionuclides, which all influence their dose distributions. Thermoluminescent dosimeters (TLDs) are often used for dose measurements around low-energy photon-emitting brachytherapy sources. TLDs are typically calibrated with higher energy sources such as 60Co, which requires a correction for the change in the response of the TLDs as a function of photon energy. These corrections have historically been based on TLD response to x ray bremsstrahlung spectra instead of to brachytherapy sources themselves. This work determined the TLD intrinsic energy dependence for 125I and 103Pd sources relative to 60Co, which allows for correction of TLD measurements of brachytherapy sources with factors specific to their energy spectra. Traditional brachytherapy sources contain mobile internal components and large amounts of high-Z material such as radio-opaque markers and titanium encapsulations. These all contribute to perturbations and uncertainties in the dose distribution around the source. The CivaString is a new elongated 103Pd brachytherapy source with a fixed internal geometry, polymer encapsulation, and lengths ranging from 1 to 6 cm, which offers advantages over traditional source designs. This work characterized the CivaString source and the results facilitated the formal approval of this source for use in clinical treatments. Additionally, the accuracy of a superposition technique for dose calculation around the sources with lengths >1 cm was verified. Advances in diagnostic techniques are paving the way for focal brachytherapy in which the dose is intentionally modulated throughout the target volume to focus on subvolumes that contain cancer cells. Brachytherapy sources with variable longitudinal strength (VLS) are a promising candidate for use in focal

  14. JEL Cylinder is moved into Crawler Transporter No. 2

    NASA Technical Reports Server (NTRS)

    2002-01-01

    KENNEDY SPACE CENTER, FLA. -- After technicians removed and replaced all of the 32 bearings located in the JEL (jacking, equalization and leveling) cylinders and reinstalled the 16 cylinders on Crawler Transporter No. 2, workers take the crawler for a test run. During routine inspections, technicians found cracks in some of the bearings in the 16 JEL cylinders on the vehicle. There are 16 cylinders and 32 bearings per crawler.

  15. The Federal Cylinder Project: A Guide to Field Cylinder Collections in Federal Agencies. Volume 8, Early Anthologies.

    ERIC Educational Resources Information Center

    Lee, Dorothy Sara, Ed; And Others

    This catalog describes wax cylinder recordings of music collected by two pioneers in ethnomusicology. The 101 cylinders in the Benjamin Ives Gilman Collection recorded at the 1893 World's Columbian Exposition in Chicago contain Fijian, Samoan, Uvean, Javanese, Turkish, and Kwakiutl or Vancouver Island Indian music. The Gilman Collection is…

  16. Adjuvant treatment for endometrial cancer: literature review and recommendations by the Comité de l'évolution des pratiques en oncologie (CEPO).

    PubMed

    Morneau, Mélanie; Foster, William; Lalancette, Marc; Van Nguyen-Huynh, Thu; Renaud, Marie-Claude; Samouëlian, Vanessa; Letarte, Nathalie; Almanric, Karine; Boily, Gino; Bouchard, Philippe; Boulanger, Jim; Cournoyer, Ghislain; Couture, Félix; Gervais, Normand; Goulet, Stéphanie; Guay, Marie-Pascale; Kavanagh, Mélanie; Lemieux, Julie; Lespérance, Bernard; Letarte, Nathalie; Morneau, Mélanie; Ouellet, Jean-François; Pineau, Gilles; Rajan, Raghu; Roy, Isabelle; Samson, Benoît; Sidéris, Lucas; Vincent, François

    2013-10-01

    Despite the very good prognosis of endometrial cancer, a number of patients with localized disease relapse following surgery. Therefore, various adjuvant therapeutic approaches have been studied. The objective of this review is to evaluate the efficacy and safety of neoadjuvant and adjuvant therapies in patients with resectable endometrial cancer and to develop evidence-based recommendations. A review of the scientific literature published between January 1990 and June 2012 was performed. The search was limited to published phase III clinical trials and meta-analyses evaluating the efficacy of neoadjuvant or adjuvant therapies in patients with endometrial carcinoma or carcinosarcoma. A total of 23 studies and five meta-analyses were identified. The selected literature showed that in patients with a low risk of recurrence, post-surgical observation is safe and recommended in most cases. There are several therapeutic modalities available for treatment of endometrial cancers with higher risk of recurrence, including vaginal brachytherapy, external beam radiotherapy, chemotherapy, or a combination of these. Considering the evidence available to date, the CEPO recommends the following: (1)post-surgical observation for most patients with a low recurrence risk; (2)adjuvant vaginal brachytherapy for patients with an intermediate recurrence risk; (3)adjuvant pelvic radiotherapy with or without vaginal brachytherapy for patients with a high recurrence risk; addition of adjuvant chemotherapy may be considered as an option for selected patients (excellent functional status, no significant co-morbidities, poor prognostic factors); (4)adjuvant chemotherapy and pelvic radiotherapy with or without brachytherapy and para-aortic irradiation for patients with advanced disease; © 2013.

  17. A woman's history of vaginal orgasm is discernible from her walk.

    PubMed

    Nicholas, Aurelie; Brody, Stuart; de Sutter, Pascal; de Carufel, François

    2008-09-01

    Research has demonstrated the association between vaginal orgasm and better mental health. Some theories of psychotherapy assert a link between muscle blocks and disturbances of both character and sexual function. In Functional-Sexological therapy, one focus of treatment is amelioration of voluntary movement. The present study examines the association of general everyday body movement with history of vaginal orgasm. The objective was to determine if appropriately trained sexologists could infer women's history of vaginal orgasm from observing only their gait. Women with known histories of either vaginal orgasm or vaginal anorgasmia were videotaped walking on the street, and their orgasmic status was judged by sexologists blind to their history. The concordance between having had orgasms triggered by penile-vaginal intercourse (not orgasm from direct clitoral stimulation) and raters' inferences of vaginal orgasm history based on observation of the woman's walk was the main outcome measure. In the sample of healthy young Belgian women (half of whom were vaginally orgasmic), history of vaginal orgasm (triggered solely by penile-vaginal intercourse) was diagnosable at far better than chance level (81.25% correct, Fisher's Exact Test P < 0.05) by appropriately trained sexologists. Clitoral orgasm history was unrelated to both ratings and to vaginal orgasm history. Exploratory analyses suggest that greater pelvic and vertebral rotation and stride length might be characteristic of the gait of women who have experienced vaginal orgasm (r = 0.51, P < 0.05). The discerning observer may infer women's experience of vaginal orgasm from a gait that comprises fluidity, energy, sensuality, freedom, and absence of both flaccid and locked muscles. Results are discussed with regard to previous research on gait, the effect of the musculature on sexual function, the special nature of vaginal orgasm, and implications for sexual therapy.

  18. Label inspection of approximate cylinder based on adverse cylinder panorama

    NASA Astrophysics Data System (ADS)

    Lin, Jianping; Liao, Qingmin; He, Bei; Shi, Chenbo

    2013-12-01

    This paper presents a machine vision system for automated label inspection, with the goal to reduce labor cost and ensure consistent product quality. Firstly, the images captured from each single-camera are distorted, since the inspection object is approximate cylindrical. Therefore, this paper proposes an algorithm based on adverse cylinder projection, where label images are rectified by distortion compensation. Secondly, to overcome the limited field of viewing for each single-camera, our method novelly combines images of all single-cameras and build a panorama for label inspection. Thirdly, considering the shake of production lines and error of electronic signal, we design the real-time image registration to calculate offsets between the template and inspected images. Experimental results demonstrate that our system is accurate, real-time and can be applied for numerous real- time inspections of approximate cylinders.

  19. Unsteady characteristics of low-Re flow past two tandem cylinders

    NASA Astrophysics Data System (ADS)

    Zhang, Wei; Dou, Hua-Shu; Zhu, Zuchao; Li, Yi

    2018-06-01

    This study investigated the two-dimensional flow past two tandem circular or square cylinders at Re = 100 and D / d = 4-10, where D is the center-to-center distance and d is the cylinder diameter. Numerical simulation was performed to comparably study the effect of cylinder geometry and spacing on the aerodynamic characteristics, unsteady flow patterns, time-averaged flow characteristics and flow unsteadiness. We also provided the first global linear stability analysis and sensitivity analysis on the physical problem for the potential application of flow control. The objective of this work is to quantitatively identify the effect of the cylinder geometry and spacing on the characteristic quantities. Numerical results reveal that there is wake flow transition for both geometries depending on the spacing. The characteristic quantities, including the time-averaged and fluctuating streamwise velocity and pressure coefficient, are quite similar to that of the single cylinder case for the upstream cylinder, while an entirely different variation pattern is observed for the downstream cylinder. The global linear stability analysis shows that the spatial structure of perturbation is mainly observed in the wake of the downstream cylinder for small spacing, while moves upstream with reduced size and is also observed after the upstream cylinder for large spacing. The sensitivity analysis reflects that the temporal growth rate of perturbation is the most sensitive to the near-wake flow of downstream cylinder for small spacing and upstream cylinder for large spacing.

  20. Diagnostic and therapeutic advancements for aerobic vaginitis.

    PubMed

    Han, Cha; Wu, Wenjuan; Fan, Aiping; Wang, Yingmei; Zhang, Huiying; Chu, Zanjun; Wang, Chen; Xue, Fengxia

    2015-02-01

    Aerobic vaginitis (AV) is a newly defined clinical entity that is distinct from candidiasis, trichomoniasis and bacterial vaginosis (BV). Because of the poor recognition of AV, this condition can lead to treatment failures and is associated with severe complications, such as pelvic inflammatory disease, infertility, preterm birth and foetal infections. This review describes the diagnosis and treatment of AV and the relationship between AV and pregnancy. The characteristics of AV include severely depressed levels of lactobacilli, increased levels of aerobic bacteria and an inflamed vagina. The diagnosis is made by microscopy on wet mounts of fresh vaginal fluid, and some distinct clinical features are recognized. Vaginal suppositories that contain kanamycin or clindamycin have shown curative effects in nonpregnant women. Additionally, the application of topical probiotics can restore the vaginal flora and reduce the recurrence of AV. Clindamycin vaginal suppositories and probiotics may be a better choice for gravida with AV than metronidazole. AV requires prompt attention, and the early diagnosis and treatment of AV during pregnancy significantly improves perinatal outcomes. Further research is needed to define the pathogenesis, diagnostic criteria and standard treatment guidelines for AV.

  1. A Study of Gas Economizing Pneumatic Cylinder

    NASA Astrophysics Data System (ADS)

    Li, T. C.; Wu, H. W.; Kuo, M. J.

    2006-10-01

    The pneumatic cylinder is the most typical actuator in the pneumatic equipment, and its mechanism is so simple that it is often used to operate point to point driving without the feedback loop in various automatic machines. But, the energy efficiency of pneumatic system is very poor compared with electrical systems and hydraulic systems. So, it is very important to discuss the energy saving for the pneumatic cylinder systems. In this thesis, we proposed three methods to apply the reduction in the air consumed for pneumatic cylinder systems. An air charge accumulator is used to absorb the exhausted compress air and a boost valve boosted the air to the higher pressure for used again. From the experiments, the direct used cylinder exhaust air may save about 40% of compress air.

  2. Application of vaginal temperature measurement in bitches.

    PubMed

    Maeder, B; Arlt, S; Burfeind, O; Heuwieser, W

    2012-12-01

    Finding innovative, non-invasive methods for continuously measuring body temperature minimizing human interference is important for accurate data collection. The objective of this study was to assess feasibility and accuracy of continuous body temperature measurements with loggers placed in the vaginal cavity of bitches. First, an in vitro experiment was performed to compare values obtained by temperature loggers (n = 26) to a calibrated liquid-in-glass thermometer. The mean differences between the two methods were low. Next, an in vivo experiment was performed using five healthy bitches, and values obtained by the vaginal loggers were compared to measurements collected rectally with digital thermometers. The results show that rectal and vaginal temperatures were correlated. The mean differences between rectal and vaginal temperatures were negligible. We conclude that the utilized temperature loggers provide accurate and reliable data. © 2012 Blackwell Verlag GmbH.

  3. In vivo TLD dose measurements in catheter-based high-dose-rate brachytherapy.

    PubMed

    Adlienė, Diana; Jakštas, Karolis; Urbonavičius, Benas Gabrielis

    2015-07-01

    Routine in vivo dosimetry is well established in external beam radiotherapy; however, it is restricted mainly to detection of gross errors in high-dose-rate (HDR) brachytherapy due to complicated measurements in the field of steep dose gradients in the vicinity of radioactive source and high uncertainties. The results of in vivo dose measurements using TLD 100 mini rods and TLD 'pin worms' in catheter-based HDR brachytherapy are provided in this paper alongside with their comparison with corresponding dose values obtained using calculation algorithm of the treatment planning system. Possibility to perform independent verification of treatment delivery in HDR brachytherapy using TLDs is discussed. © The Author 2015. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.

  4. Imaging method for monitoring delivery of high dose rate brachytherapy

    DOEpatents

    Weisenberger, Andrew G; Majewski, Stanislaw

    2012-10-23

    A method for in-situ monitoring both the balloon/cavity and the radioactive source in brachytherapy treatment utilizing using at least one pair of miniature gamma cameras to acquire separate images of: 1) the radioactive source as it is moved in the tumor volume during brachytherapy; and 2) a relatively low intensity radiation source produced by either an injected radiopharmaceutical rendering cancerous tissue visible or from a radioactive solution filling a balloon surgically implanted into the cavity formed by the surgical resection of a tumor.

  5. Size effect and cylinder test on several commercial explosives

    NASA Astrophysics Data System (ADS)

    Souers, P. Clark; Lauderbach, Lisa; Moua, Kou; Garza, Raul

    2012-03-01

    Some size (diameter) effect and the Cylinder test results for Kinepak (ammonium nitrate/nitromethane), Semtex 1, Semtex H and urea nitrate are presented. Cylinder test data appears normal despite faster sound speeds in the copper wall. Most explosives come to steady state in the Cylinder test as expected, but Kinepak shows a steadily increasing wall velocity with distance down the cylinder. Some data on powder densities as a function of loading procedure are also given.

  6. Creation of an acellular vaginal matrix for potential vaginal augmentation and cloacal repair.

    PubMed

    Greco, K V; Jones, L G; Obiri-Yeboa, I; Ansari, T

    2018-05-21

    our aim was to use porcine vagina to create a vaginal matrix and test its cellular biocompatibility. vagina was harvested from pigs and de-cellularised (DC) using a combination of detergents (Triton x-100 and sodium deoxycholate) and enzymes (DNAse/RNAse). the presence of cellular material, collagen structural integrity and basement membrane proteins were assessed histologically. To address cytocompatibility, porcine adipose derived-mesenchymal stem cells (AD-MSC) were harvested from abdominal fat together with vaginal epithelial cells (VEC) and seeded onto the mucosal aspect of the vaginal scaffold. Both cells populations were seeded individually and assessed histologically at days 3 and 10. MAIN OUTCOMES/RESULTS: the combination of enzymes and detergents resulted in a totally acellular matrix with very low DNA amount (control= 97.5ng/μl ± 10.8 vs DC= 40.1 ng/μl ±0.33 p=0.02). The extra cellular matrix (ECM) showed retention of collagen fibres and elastin and a 50% retention in glycosaminoglycan content; (control= 1.18μg/mg ± 0.28 DC = 1.35μg/mg ± 0.1 p=0.03) and an intact basement membrane (positive for both laminin and collagen IV). Seeded scaffolds showed cell attachment with both AD-MSC and VEC at days 3 and 10. it is possible to generate an acellular porcine vaginal matrix capable of supporting cells to reconstruct the vagina for future pre-clinical testing, and holds promise for creating clinically relevant sized tissue for human application. Copyright © 2018. Published by Elsevier Inc.

  7. Enrichment Assay Methods Development for the Integrated Cylinder Verification System

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Smith, Leon E.; Misner, Alex C.; Hatchell, Brian K.

    2009-10-22

    International Atomic Energy Agency (IAEA) inspectors currently perform periodic inspections at uranium enrichment plants to verify UF6 cylinder enrichment declarations. Measurements are typically performed with handheld high-resolution sensors on a sampling of cylinders taken to be representative of the facility's entire product-cylinder inventory. Pacific Northwest National Laboratory (PNNL) is developing a concept to automate the verification of enrichment plant cylinders to enable 100 percent product-cylinder verification and potentially, mass-balance calculations on the facility as a whole (by also measuring feed and tails cylinders). The Integrated Cylinder Verification System (ICVS) could be located at key measurement points to positively identify eachmore » cylinder, measure its mass and enrichment, store the collected data in a secure database, and maintain continuity of knowledge on measured cylinders until IAEA inspector arrival. The three main objectives of this FY09 project are summarized here and described in more detail in the report: (1) Develop a preliminary design for a prototype NDA system, (2) Refine PNNL's MCNP models of the NDA system, and (3) Procure and test key pulse-processing components. Progress against these tasks to date, and next steps, are discussed.« less

  8. Douching With Water Works Device for Perceived Vaginal Odor With or Without Complaints of Discharge in Women With No Infectious Cause of Vaginitis: A Pilot Study

    PubMed Central

    Chatwani, Ashwin J.; Hassan, Sarmina; Rahimi, Salma; Jeronis, Stacey; Dandolu, Vani

    2006-01-01

    Objective. To determine if douching with Water Works device for 1 month can (1) lower or eliminate perceived vaginal odor by subject; (2) have any effects on vaginal ecosystem. Methods. Ten women with perceived vaginal odor with or without discharge, douched every day for 4 weeks in an open-label, nonrandomized pilot study. Primary outcome measures included perceived vaginal odor by subject, lactobacilli score from Nugent slide, and acceptance of the Water Works douching system. Secondary outcome included the safety of using this douching device. Results. At week 4, there was improvement in vaginal odor (P = .0006) and there was no significant change in lactobacilli score. Conclusion. Douching with Water Works device is associated with reduction or elimination of vaginal odor without adversely affecting the vaginal ecosystem. PMID:17485816

  9. Stresses in and General Instability of Monocoque Cylinders with Cutouts I : Experimental Investigation of Cylinders with a Symmetric Cutout Subjected to Pure Bending

    NASA Technical Reports Server (NTRS)

    Hoff, N J; Boley, Bruno A

    1946-01-01

    Ten 24S-T alclad cylinders of 20-inch diameter, 45- or 58-inch length, and 0.012-inch wall thickness, reinforced with 24S-T aluminum alloy stringers and rings were tested in pure bending. In the middle of the compression side of the cylinders there was a cutout extending over 19 inches in the longitudinal direction, and over an angle of 45 degrees, 90 degrees, or 135 degrees in the circumferential direction. The strain in the stringers and in the sheet covering was measured with metal electric strain gages. The stress distribution in the cylinders deviate considerably from the linear law valid for cylinders without a cutout. The maximum strain measured was about four-thirds of the value calculated from the Mc/I formula when I was taken as the moment of inertia of the cross section of the portion of the cylinder where the cutout was situated. A diagram is presented containing the strain factors defined as the ratios of measured strain to strain calculated with the Mc/I formula. All the 10 cylinders tested failed in general instability. Two symmetric and one antisymmetric pattern of buckling were observed and the buckling load appeared to be independent of the method of manufacture and the length of the cylinder. The buckling load of the cylinders having cutouts extending over 45 degrees, 90 degrees, and 135 degrees was 66, 47, and 31 percent, respectively, of the buckling load of the cylinder without a cutout.

  10. Variation in vaginal breech delivery rates by hospital type.

    PubMed

    Gregory, K D; Korst, L M; Krychman, M; Cane, P; Platt, L D

    2001-03-01

    To relate vaginal breech delivery rates to the following hospital types: public, health maintenance organization, private teaching, or private nonteaching. In a retrospective study using administrative discharge data from Los Angeles County, California, we calculated the vaginal breech delivery rates of singleton breech deliveries during calendar years 1988 and 1991. Ten thousand four hundred breech deliveries were identified, 8988 (86.4%) term and 1412 (13.6%) preterm. Twelve percent (1252 of 10,400) were vaginal deliveries (10.1% term and 24.5% preterm). Term vaginal breech deliveries varied by hospital type and were more frequent in public hospitals (28.4%, 95% confidence interval [CI] 26.1%, 30.7%) and less frequent in private nonteaching hospitals (5.4%, 95% CI 4.8%, 5.9%). Term vaginal deliveries were 2.4 to 11.3 times more likely among black women and 1.3 to 6.3 times more likely for Hispanic women across all hospital types, compared with white women in private nonteaching hospitals. There was no difference in the proportion of preterm vaginal breech deliveries by hospital type (mean 24.5%). However, with the exception of public hospitals, the proportion of vaginal breech deliveries for both term and preterm deliveries varied significantly by ethnicity. The use of vaginal breech delivery varied by hospital type and patient ethnicity. Within private teaching and nonteaching hospitals, vaginal breech delivery was more likely for black women than for women of other ethnic groups. Further study is needed to understand the hospital policies or organizational factors, as well as the patient-related sociocultural and clinical factors, that contribute to those differences.

  11. Review of Vaginitis

    PubMed Central

    1993-01-01

    Adisruption of the dynamic equilibrium of the healthy vagina may have significant sequelae, leading to chronic or serious conditions. Therefore, all cases of vaginitis should be accurately diagnosed and appropriately treated. PMID:18475337

  12. Effect of vaginal distention on elastic fiber synthesis and matrix degradation in the vaginal wall: potential role in the pathogenesis of pelvic organ prolapse

    PubMed Central

    Rahn, D. D.; Acevedo, J. F.; Word, R. A.

    2008-01-01

    Matrix metalloprotease (MMP) activity is increased in the postpartum vagina of wild-type (WT) animals. This degradative activity is also accompanied by a burst in elastic fiber synthesis and assembly. The mechanisms that precipitate these changes are unclear. The goals of this study were to determine how vaginal distention (such as in parturition) affects elastic fiber homeostasis in the vaginal wall and the potential significance of these changes in the pathogenesis of pelvic organ prolapse. Vaginal distention with a balloon simulating parturition resulted in increased MMP-2 and MMP-9 activity in the vaginal wall of nonpregnant and pregnant animals. This was accompanied by visible fragmented and disrupted elastic fibers in the vaginal wall. In nonpregnant animals, the abundant amounts of tropoelastin and fibulin-5 in the vagina were not increased further by distention. In contrast, in pregnant animals, the suppressed levels of both proteins were increased 3-fold after vaginal distention. Distention performed in fibulin-5-deficient (Fbln5−/−) mice with defective elastic fiber synthesis and assembly induced accelerated pelvic organ prolapse, which never recovered. We conclude that, in pregnant mice, vaginal distention results in increased protease activity in the vaginal wall but also increased synthesis of proteins important for elastic fiber assembly. Distention may thereby contribute to the burst of elastic fiber synthesis in the postpartum vagina. The finding that distention results in accelerated pelvic organ prolapse in Fbln5−/− animals, but not in WT, indicates that elastic fiber synthesis is crucial for recovery of the vaginal wall from distention-induced increases in vaginal protease activity. PMID:18635445

  13. Application of the low-level laser therapy for the treatment of vaginitis

    NASA Astrophysics Data System (ADS)

    Passeniouk, A. N.; Mikhailov, V. A.

    2000-06-01

    Vaginitis is the most common female infectious disease. Females suffering from this disorder are annually increasing in number. There are a lot of modalities of treatment of vaginitis, but because of drug allergy and microbe's stability to drug the treatment of vaginitis is difficult. Our study compares the efficacy of laser-therapy with drug therapy in the treatment of non-specific vaginitis and vaginal candidiasis. Thirty women reci4eed the LLLT by local action with antiseptic liquid daily during ten days, 20 women received metronidazole and fluconozole and vaginal application of metronidazole. The results suggest that local laser-therapy is able to remove sights of vaginitis more efficiently and faster than drug therapy. Repair of normal vaginal microflora, which is the best indicator of recovery, was significantly at a faster rate in laser-therapy group. There were no report of adverse reaction with vaginal laser- therapy, whereas there were women on drug therapy who reported side effects. In conclusion, vaginal aser-therapy with antiseptic liquid is a suitable, effective, safe and chip alternative to drug therapy in the treatment of vaginitis.

  14. MONOMIALS AND BASIN CYLINDERS FOR NETWORK DYNAMICS.

    PubMed

    Austin, Daniel; Dinwoodie, Ian H

    We describe methods to identify cylinder sets inside a basin of attraction for Boolean dynamics of biological networks. Such sets are used for designing regulatory interventions that make the system evolve towards a chosen attractor, for example initiating apoptosis in a cancer cell. We describe two algebraic methods for identifying cylinders inside a basin of attraction, one based on the Groebner fan that finds monomials that define cylinders and the other on primary decomposition. Both methods are applied to current examples of gene networks.

  15. MONOMIALS AND BASIN CYLINDERS FOR NETWORK DYNAMICS

    PubMed Central

    AUSTIN, DANIEL; DINWOODIE, IAN H

    2014-01-01

    We describe methods to identify cylinder sets inside a basin of attraction for Boolean dynamics of biological networks. Such sets are used for designing regulatory interventions that make the system evolve towards a chosen attractor, for example initiating apoptosis in a cancer cell. We describe two algebraic methods for identifying cylinders inside a basin of attraction, one based on the Groebner fan that finds monomials that define cylinders and the other on primary decomposition. Both methods are applied to current examples of gene networks. PMID:25620893

  16. Medium-term clinical outcomes following surgical repair for vaginal prolapse with tension-free mesh and vaginal support device.

    PubMed

    Sayer, T; Lim, J; Gauld, J M; Hinoul, P; Jones, P; Franco, N; Van Drie, D; Slack, M

    2012-04-01

    This study was designed to evaluate clinical outcomes ≥2 years following surgery with polypropylene mesh and vaginal support device (VSD) in women with vaginal prolapse, in a prospective, multi-center setting. Patients re-consented for this extended follow-up (n = 110), with anatomic evaluation using Pelvic Organ Prolapse Quantification (POP-Q) and validated questionnaires to assess pelvic symptoms and sexual function. Complications were recorded (safety set; n = 121). Median length of follow-up was 29 months (range 24-34 months). The primary anatomic success, defined as POP-Q 0-I, was 69.1%; however, in 84.5% of the cases, the leading vaginal edge was above the hymen. Pelvic symptoms and sexual function improved significantly from baseline (p < 0.01). Mesh exposure rate was 9.1%. Five percent reported stress urinary incontinence and 3.3% required further prolapse surgery. These results indicate this non-anchored mesh repair is a safe and effective treatment for women with symptomatic vaginal prolapse in the medium term.

  17. Implantable chemothermal brachytherapy seeds: A synergistic approach to brachytherapy using polymeric dual drug delivery and hyperthermia for malignant solid tumor ablation.

    PubMed

    Aguilar, Ludwig Erik; Thomas, Reju George; Moon, Myeong Ju; Jeong, Yong Yeon; Park, Chan Hee; Kim, Cheol Sang

    2018-08-01

    Chemothermal brachytherapy seeds have been developed using a combination of polymeric dual drug chemotherapy and alternating magnetic field induced hyperthermia. The synergistic effect of chemotherapy and hyperthermia brachytherapy has been investigated in a way that has never been performed before, with an in-depth analysis of the cancer cell inhibition property of the new system. A comprehensive in vivo study on athymic mice model with SCC7 tumor has been conducted to determine optimal arrays and specifications of the chemothermal seeds. Dual drug chemotherapy has been achieved via surface deposition of polydopamine that carries bortezomib, and also via loading an acidic pH soluble hydrogel that contains 5-Fluorouracil inside the chemothermal seed; this increases the drug loading capacity of the chemothermal seed, and creates dual drug synergism. An external alternating magnetic field has been utilized to induce hyperthermia conditions, using the inherent ferromagnetic property of the nitinol alloy used as the seed casing. The materials used in this study were fully characterized using FESEM, H 1 NMR, FT-IR, and XPS to validate their properties. This new approach to experimental cancer treatment is a pilot study that exhibits the potential of thermal brachytherapy and chemotherapy as a combined treatment modality. Copyright © 2018 Elsevier B.V. All rights reserved.

  18. Vaginal cytokines do not correlate with postmenopausal vulvovaginal symptoms.

    PubMed

    Kollmann, Zahraa; Bersinger, Nick; von Wolff, Michael; Thurman, Andrea R; Archer, David F; Stute, Petra

    2015-04-01

    Exploratory pilot study to determine the correlation between postmenopausal vulvovaginal symptoms and vaginal cytokine levels. Postmenopausal women (n = 34) not using menopausal hormone therapy and presenting with or without symptoms of vulvovaginal irritation were screened. Each participant underwent a vaginal examination and screening for vaginitis. A cervicovaginal lavage (CVL) with sterile saline and a peripheral blood sample were obtained. Main outcome measures were assessed by Luminex® X-map method on the Bio-Plex® platform. Main outcome measures were cervicovaginal and serum interleukin (IL)-4, IL-5, IL-10, IL-12, IL-13, TNF-α, GM-CSF, MIP-1-alpha and RANTES level. Cervicovaginal cytokines were adjusted to total protein concentration [pg/mcg protein]. Twenty-six postmenopausal women were enrolled (symptomatic: n = 15; asymptomatic: n = 11). There were no significant differences between groups: age, age at menopause, vaginal pH and all CVL and serum cytokines (IL-4, IL-5, IL-10, IL-12, IL-13, TNF-α, GM-CSF, MIP-1-alpha and RANTES). GM-CSF was the most abundant vaginal cytokine (symptomatic: 146.5 ± 165.6 pg/mcg protein; asymptomatic: 146.0 ± 173.5 pg/mcg protein; p = 0.99). Postmenopausal vulvovaginal symptoms did not correlate with vaginal inflammatory marker. There was no difference in serum or CVL cytokines between symptomatic and asymptomatic postmenopasual women. Vaginal symptoms after menopause are not related to the vaginal cytokine changes associated with loss of estrogen.

  19. CT-based MCNPX dose calculations for gynecology brachytherapy employing a Henschke applicator

    NASA Astrophysics Data System (ADS)

    Yu, Pei-Chieh; Nien, Hsin-Hua; Tung, Chuan-Jong; Lee, Hsing-Yi; Lee, Chung-Chi; Wu, Ching-Jung; Chao, Tsi-Chian

    2017-11-01

    The purpose of this study is to investigate the dose perturbation caused by the metal ovoid structures of a Henschke applicator using Monte Carlo simulation in a realistic phantom. The Henschke applicator has been widely used for gynecologic patients treated by brachytherapy in Taiwan. However, the commercial brachytherapy planning system (BPS) did not properly evaluate the dose perturbation caused by its metal ovoid structures. In this study, Monte Carlo N-Particle Transport Code eXtended (MCNPX) was used to evaluate the brachytherapy dose distribution of a Henschke applicator embedded in a Plastic water phantom and a heterogeneous patient computed tomography (CT) phantom. The dose comparison between the MC simulations and film measurements for a Plastic water phantom with Henschke applicator were in good agreement. However, MC dose with the Henschke applicator showed significant deviation (-80.6%±7.5%) from those without Henschke applicator. Furthermore, the dose discrepancy in the heterogeneous patient CT phantom and Plastic water phantom CT geometries with Henschke applicator showed 0 to -26.7% dose discrepancy (-8.9%±13.8%). This study demonstrates that the metal ovoid structures of Henschke applicator cannot be disregard in brachytherapy dose calculation.

  20. Heat-transfer processes in air-cooled engine cylinders

    NASA Technical Reports Server (NTRS)

    Pinkel, Benjamin

    1938-01-01

    From a consideration of heat-transfer theory, semi-empirical expressions are set up for the transfer of heat from the combustion gases to the cylinder of an air-cooled engine and from the cylinder to the cooling air. Simple equations for the average head and barrel temperatures as functions of the important engine and cooling variables are obtained from these expressions. The expressions involve a few empirical constants, which may be readily determined from engine tests. Numerical values for these constants were obtained from single-cylinder engine tests for cylinders of the Pratt & Whitney 1535 and 1340-h engines. The equations provide a means of calculating the effect of the various engine and cooling variables on the cylinder temperatures and also of correlating the results of engine cooling tests. An example is given of the application of the equations to the correlation of cooling-test data obtained in flight.