Miles, Dale R; Mesfin, Mimi; Mody, Tarak D; Stiles, Mark; Lee, Jean; Fiene, John; Denis, Bernie; Boswell, Garry W
2006-05-01
Liquid chromatography-fluorescence (LC-FLS), liquid chromatography-tandem mass spectrometry (LC-MS/MS) and inductively coupled plasma-mass spectrometry (ICP-MS) methods were developed and validated for the evaluation of motexafin gadolinium (MGd, Xcytrin) pharmacokinetics and biodistribution in plasma and tissues. The LC-FLS method exhibited the greatest sensitivity (0.0057 microg mL(-1)), and was used for pharmacokinetic, biodistribution, and protein binding studies with small sample sizes or low MGd concentrations. The LC-MS/MS method, which exhibited a short run time and excellent selectivity, was used for routine clinical plasma sample analysis. The ICP-MS method, which measured total Gd, was used in conjunction with LC methods to assess MGd stability in plasma. All three methods were validated using human plasma. The LC-FLS method was also validated using plasma, liver and kidneys from mice and rats. All three methods were shown to be accurate, precise and robust for each matrix validated. For three mice, the mean (standard deviation) concentration of MGd in plasma/tissues taken 5 hr after dosing with 23 mg kg(-1) MGd was determined by LC-FLS as follows: plasma (0.025+/-0.002 microg mL(-1)), liver (2.89+/-0.45 microg g(-1)), and kidney (6.09+/-1.05 microg g(-1)). Plasma samples from a subset of patients with brain metastases from extracranial tumors were analyzed using both LC-MS/MS and ICP-MS methods. For a representative patient, > or = 90% of the total Gd in plasma was accounted for as MGd over the first hour post dosing. By 24 hr post dosing, 63% of total Gd was accounted for as MGd, indicating some metabolism of MGd.
Yang, Samuel H; Wang, Jenny; Zhang, Kelly
2017-04-07
Despite the advantages of 2D-LC, there is currently little to no work in demonstrating the suitability of these 2D-LC methods for use in a quality control (QC) environment for good manufacturing practice (GMP) tests. This lack of information becomes more critical as the availability of commercial 2D-LC instrumentation has significantly increased, and more testing facilities begin to acquire these 2D-LC capabilities. It is increasingly important that the transferability of developed 2D-LC methods be assessed in terms of reproducibility, robustness and performance across different laboratories worldwide. The work presented here focuses on the evaluation of a heart-cutting 2D-LC method used for the analysis of a pharmaceutical material, where a key, co-eluting impurity in the first dimension ( 1 D) is resolved from the main peak and analyzed in the second dimension ( 2 D). A design-of-experiments (DOE) approach was taken in the collection of the data, and the results were then modeled in order to evaluate method robustness using statistical modeling software. This quality by design (QBD) approach gives a deeper understanding of the impact of these 2D-LC critical method attributes (CMAs) and how they affect overall method performance. Although there are multiple parameters that may be critical from method development point of view, a special focus of this work is devoted towards evaluation of unique 2D-LC critical method attributes from method validation perspective that transcend conventional method development and validation. The 2D-LC method attributes are evaluated for their recovery, peak shape, and resolution of the two co-eluting compounds in question on the 2 D. In the method, linearity, accuracy, precision, repeatability, and sensitivity are assessed along with day-to-day, analyst-to-analyst, and lab-to-lab (instrument-to-instrument) assessments. The results of this validation study demonstrate that the 2D-LC method is accurate, sensitive, and robust and is ultimately suitable for QC testing with good method transferability. Copyright © 2017 Elsevier B.V. All rights reserved.
Dubreil, Estelle; Gautier, Sophie; Fourmond, Marie-Pierre; Bessiral, Mélaine; Gaugain, Murielle; Verdon, Eric; Pessel, Dominique
2017-04-01
An approach is described to validate a fast and simple targeted screening method for antibiotic analysis in meat and aquaculture products by LC-MS/MS. The strategy of validation was applied for a panel of 75 antibiotics belonging to different families, i.e., penicillins, cephalosporins, sulfonamides, macrolides, quinolones and phenicols. The samples were extracted once with acetonitrile, concentrated by evaporation and injected into the LC-MS/MS system. The approach chosen for the validation was based on the Community Reference Laboratory (CRL) guidelines for the validation of screening qualitative methods. The aim of the validation was to prove sufficient sensitivity of the method to detect all the targeted antibiotics at the level of interest, generally the maximum residue limit (MRL). A robustness study was also performed to test the influence of different factors. The validation showed that the method is valid to detect and identify 73 antibiotics of the 75 antibiotics studied in meat and aquaculture products at the validation levels.
DBS-LC-MS/MS assay for caffeine: validation and neonatal application.
Bruschettini, Matteo; Barco, Sebastiano; Romantsik, Olga; Risso, Francesco; Gennai, Iulian; Chinea, Benito; Ramenghi, Luca A; Tripodi, Gino; Cangemi, Giuliana
2016-09-01
DBS might be an appropriate microsampling technique for therapeutic drug monitoring of caffeine in infants. Nevertheless, its application presents several issues that still limit its use. This paper describes a validated DBS-LC-MS/MS method for caffeine. The results of the method validation showed an hematocrit dependence. In the analysis of 96 paired plasma and DBS clinical samples, caffeine levels measured in DBS were statistically significantly lower than in plasma but the observed differences were independent from hematocrit. These results clearly showed the need for extensive validation with real-life samples for DBS-based methods. DBS-LC-MS/MS can be considered to be a good alternative to traditional methods for therapeutic drug monitoring or PK studies in preterm infants.
This document is a standardized single laboratory validated liquid chromatography/tandem mass spectrometry (LC/MS/MS) method for the detection and quantification of cyanotoxins (combined intracellular and extracellular) in ambient freshwaters.
USDA-ARS?s Scientific Manuscript database
A liquid chromatography-mass spectrometry (LC/MS) method for simultaneous quantitation of seven ergot alkaloids (lysergic acid, ergonovine, ergovaline, ergocornine, ergotamine, ergocryptine and ergocrystine) in vascular tissue was developed and validated. Reverse-phase chromatography, coupled to an...
This document is a standardized, single laboratory validated liquid chromatography/tandem mass spectrometry (LC/MS/MS) method for the detection of cyanotoxins—microsystins and nodularin (combined intracellular and extracellular)—in ambient freshwaters.
This product is an LC/MS/MS single laboratory validated method for the determination of cylindrospermopsin and anatoxin-a in ambient waters. The product contains step-by-step instructions for sample preparation, analyses, preservation, sample holding time and QC protocols to ensu...
Park, Ah Yeon; Park, So-Young; Lee, Jaehyun; Jung, Mihye; Kim, Jinwoong; Kang, Sam Sik; Youm, Jeong-Rok; Han, Sang Beom
2009-10-01
Rapid, simple and reliable HPLC/UV and LC-ESI-MS/MS methods for the simultaneous determination of five active coumarins of Angelicae dahuricae Radix, byakangelicol (1), oxypeucedanin (2), imperatorin (3), phellopterin (4) and isoimperatorin (5) were developed and validated. The separation condition for HPLC/UV was optimized using a Develosil RPAQUEOUS C(30) column using 70% acetonitrile in water as the mobile phase. This HPLC/UV method was successful for providing the baseline separation of the five coumarins with no interfering peaks detected in the 70% ethanol extract of Angelicae dahuricae Radix. The specific determination of the five coumarins was also accomplished by a triple quadrupole tandem mass spectrometer equipped with an electrospray ionization source (LC-ESI-MS/MS). Multiple reaction monitoring (MRM) in the positive mode was used to enhance the selectivity of detection. The LC-ESI-MS/MS methods were successfully applied for the determination of the five major coumarins in Angelicae dahuricae Radix. These HPLC/UV and LC-ESI-MS/MS methods were validated in terms of recovery, linearity, accuracy and precision (intra- and inter-day validation). Taken together, the shorter analysis time involved makes these HPLC/UV and LC-ESI-MS/MS methods valuable for the commercial quality control of Angelicae dahuricae Radix extracts and its pharmaceutical preparations. Copyright (c) 2009 John Wiley & Sons, Ltd.
Peixoto, Maria Paula Garofo; Kaiser, Samuel; Verza, Simone Gasparin; de Resende, Pedro Ernesto; Treter, Janine; Pavei, Cabral; Borré, Gustavo Luís; Ortega, George González
2012-01-01
Ilex paraguariensis A. St. Hil. (mate) is known in several South American countries because of the use of its leaves in stimulant herbal beverages. High saponin contents were reported in mate leaves and unripe fruits that possess a dissimilar composition. Two LC-UV methods previously reported for mate saponins assay focused on mate leaves and the quantification of the less polar saponin fraction in mate fruits. To develop and validate a LC-UV method to assay the total content of saponins in unripe mate fruits and characterise the chemical structure of triterpenic saponins by UPLC/Q-TOF-MS. From unripe fruits of mate a crude ethanolic extract was prepared (EX40) and the mate saponin fraction (MSF) purified by solid phase extraction. The LC-UV method was validated using ilexoside II as external standard. UPLC/Q-TOF-MS was adjusted from the LC-UV method to obtain the fragmentation patterns of the main saponins present in unripe fruits. Both LC-UV and UPLC/Q-TOF-MS methods indicate a wide range of Ilex saponins polarity. The ilexoside II and total saponin content of EX40 were 8.20% (w/w) and 47.60% (w/w), respectively. The total saponin content in unripe fruits was 7.28% (w/w). The saponins present in MSF characterised by UPLC/Q-TOF-MS are derived mainly from ursolic/oleanolic, acetyl ursolic or pomolic acid. The validated LC-UV method was shown to be linear, precise, accurate and to cover several saponins previously isolated from Ilex species and could be applied for the quality control of unripe fruit saponins. Copyright © 2011 John Wiley & Sons, Ltd.
Patient-specific lean body mass can be estimated from limited-coverage computed tomography images.
Devriese, Joke; Beels, Laurence; Maes, Alex; van de Wiele, Christophe; Pottel, Hans
2018-06-01
In PET/CT, quantitative evaluation of tumour metabolic activity is possible through standardized uptake values, usually normalized for body weight (BW) or lean body mass (LBM). Patient-specific LBM can be estimated from whole-body (WB) CT images. As most clinical indications only warrant PET/CT examinations covering head to midthigh, the aim of this study was to develop a simple and reliable method to estimate LBM from limited-coverage (LC) CT images and test its validity. Head-to-toe PET/CT examinations were retrospectively retrieved and semiautomatically segmented into tissue types based on thresholding of CT Hounsfield units. LC was obtained by omitting image slices. Image segmentation was validated on the WB CT examinations by comparing CT-estimated BW with actual BW, and LBM estimated from LC images were compared with LBM estimated from WB images. A direct method and an indirect method were developed and validated on an independent data set. Comparing LBM estimated from LC examinations with estimates from WB examinations (LBMWB) showed a significant but limited bias of 1.2 kg (direct method) and nonsignificant bias of 0.05 kg (indirect method). This study demonstrates that LBM can be estimated from LC CT images with no significant difference from LBMWB.
Emory, Joshua F.; Seserko, Lauren A.; Marzinke, Mark A.
2014-01-01
Background Maraviroc is a CCR5 antagonist that has been utilized as a viral entry inhibitor in the management of HIV-1. Current clinical trials are pursuing maraviroc drug efficacy in both oral and topical formulations. Therefore, in order to fully understand drug pharmacokinetics, a sensitive method is required to quantify plasma drug concentrations. Methods Maraviroc-spiked plasma was combined with acetonitrile containing an isotopically-labeled internal standard, and following protein precipitation, samples were evaporated to dryness and reconstituted for liquid chromatographic-tandem mass spectrometric (LC-MS/MS) analysis. Chromatographic separation was achieved on a Waters BEH C8, 50 × 2.1 mm UPLC column, with a 1.7 μm particle size and the eluent was analyzed using an API 4000 mass analyzer in selected reaction monitoring mode. The method was validated as per FDA Bioanalytical Method Validation guidelines. Results The analytical measuring range of the LC-MS/MS method is 0.5-1000 ng/ml. Calibration curves were generated using weighted 1/x2 quadratic regression. Inter-and intra-assay precision was ≤ 5.38% and ≤ 5.98%, respectively; inter-and intra-assay accuracy (%DEV) was ≤ 10.2% and ≤ 8.44%, respectively. Additional studies illustrated similar matrix effects between maraviroc and its internal standard, and that maraviroc is stable under a variety of conditions. Method comparison studies with a reference LC-MS/MS method show a slope of 0.948 with a Spearman coefficient of 0.98. Conclusions Based on the validation metrics, we have generated a sensitive and automated LC-MS/MS method for maraviroc quantification in human plasma. PMID:24561264
Rama Raju, Kanumuri Siva; Taneja, Isha; Singh, Sheelendra Pratap; Tripathi, Amit; Mishra, Durga Prasad; Hussain, K Mahaboob; Gayen, Jiaur Rahman; Singh, Shio Kumar; Wahajuddin, Muhammad
2015-01-01
Tamoxifen and centchroman are two non-steroidal, selective estrogen receptors modulators, intended for long term therapy in the woman. Because of their wide spread use, there is a possibility of co-prescription of these agents. We studied the probable pharmacokinetic interaction between these agents in breast cancer model rats. A simple, sensitive and rapid LC-ESI-MS/MS method was developed and validated for the simultaneous determination of tamoxifen, centchroman and their active metabolites. The method was linear over a range of 0.2-200 ng/ml. All validation parameters met the acceptance criteria according to regulatory guidelines. LC-MS/MS method for determination of tamoxifen, centchroman and their metabolites was developed and validated. Results show the potential of drug-drug interaction upon co-administration these two marketed drugs.
Sandra, Koen; Mortier, Kjell; Jorge, Lucie; Perez, Luis C; Sandra, Pat; Priem, Sofie; Poelmans, Sofie; Bouche, Marie-Paule
2014-05-01
Nanobodies(®) are therapeutic proteins derived from the smallest functional fragments of heavy chain-only antibodies. The development and validation of an LC-MS/MS-based method for the quantification of an IgE binding Nanobody in cynomolgus monkey plasma is presented. Nanobody quantification was performed making use of a proteotypic tryptic peptide chromatographically enriched prior to LC-MS/MS analysis. The validated LLOQ at 36 ng/ml was measured with an intra- and inter-assay precision and accuracy <20%. The required sensitivity could be obtained based on the selectivity of 2D LC combined with MS/MS. No analyte specific tools for affinity purification were used. Plasma samples originating from a PK/PD study were analyzed and compared with the results obtained with a traditional ligand-binding assay. Excellent correlations between the two techniques were obtained, and similar PK parameters were estimated. A 2D LC-MS/MS method was successfully developed and validated for the quantification of a next generation biotherapeutic.
Yang, He S; Wu, Alan H B; Lynch, Kara L
2016-06-01
With the rise in the use and misuse of prescription opioids, there is an increasing need for the confirmed identification of opioid analgesics in toxicology laboratories. The goals of this study were to (i) systematically evaluate the hydrolysis efficiency of four β-glucuronidase enzymes under optimized condition; (ii) evaluate compound recovery, matrix effects and precision of three protein precipitation plates and (iii) develop and validate a qualitative liquid-chromatography mass spectrometry (LC-MS/MS) assay to identify 13 opioids in urine. A recombinant β-glucuronidase exhibited the best overall hydrolysis efficiency for seven opioid glucuronide conjugates compared with β-glucuronidase from red abalone, Escherichia coli and Patella vulgata One of the protein precipitation plates tested exhibited overall better recovery of the opioids and lower ion suppression compared with the other two plates. An ESI positive mode LC-MS/MS assay for qualitative opioid analysis was developed and validated. Linearity, LOD, precision, matrix effect, recovery, carryover and interference of the method were evaluated. Sixty-two patient samples were analyzed by both a legacy GC-MS opioid method and the LC-MS/MS method, and 22 samples were analyzed by the LC-MS/MS and an LC-MS/MS reference method. The results of the comparisons showed good concordance. Overall, we described an efficient sample preparation procedure for a sensitive qualitative opioid confirmation assay in urine. © The Author 2016. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.
Barco, Sebastiano; Castagnola, Elio; Moscatelli, Andrea; Rudge, James; Tripodi, Gino; Cangemi, Giuliana
2017-10-25
In this paper we show the development and validation of a volumetric absorptive microsampling (VAMS™)-LC-MS/MS method for the simultaneous quantification of four antibiotics: piperacillin-tazobactam, meropenem, linezolid and ceftazidime in 10μL human blood. The novel VAMS-LC-MS/MS method has been compared with a dried blood spot (DBS)-based method in terms of impact of hematocrit (HCT) on accuracy, reproducibility, recovery and matrix effect. Antibiotics were extracted from VAMS and DBS by protein precipitation with methanol after a re-hydration step at 37°C for 10min. LC-MS/MS was carried out on a Thermo Scientific™ TSQ Quantum™ Access MAX triple quadrupole coupled to an Accela ™UHPLC system. The VAMS-LC-MS/MS method is selective, precise and reproducible. In contrast to DBS, it allows an accurate quantification without any HCT influence. It has been applied to samples derived from pediatric patients under therapy. VAMS is a valid alternative sampling strategy for the quantification of antibiotics and is valuable in support of clinical PK/PD studies and consequently therapeutic drug monitoring (TDM) in pediatrics. Copyright © 2017 Elsevier B.V. All rights reserved.
Jiang, Hui; Sidhu, Rohini; Fujiwara, Hideji; De Meulder, Marc; de Vries, Ronald; Gong, Yong; Kao, Mark; Porter, Forbes D.; Yanjanin, Nicole M.; Carillo-Carasco, Nuria; Xu, Xin; Ottinger, Elizabeth; Woolery, Myra; Ory, Daniel S.; Jiang, Xuntian
2014-01-01
2-Hydroxypropyl-β-cyclodextrin (HP-β-CD), a widely used excipient for drug formulation, has emerged as an investigational new drug for the treatment of Niemann-Pick type C1 (NPC1) disease, a neurodegenerative cholesterol storage disorder. Development of a sensitive quantitative LC-MS/MS assay to monitor the pharmacokinetics (PKs) of HP-β-CD required for clinical trials has been challenging owing to the dispersity of the HP-β-CD. To support a phase 1 clinical trial for ICV delivery of HP-β-CD in NPC1 patients, novel methods for quantification of HP-β-CD in human plasma and cerebrospinal fluid (CSF) using LC-MS/MS were developed and validated: a 2D-LC-in-source fragmentation-MS/MS (2D-LC-IF-MS/MS) assay and a reversed phase ultra performance LC-MS/MS (RP-UPLC-MS/MS) assay. In both assays, protein precipitation and “dilute and shoot” procedures were used to process plasma and CSF, respectively. The assays were fully validated and in close agreement, and allowed determination of PK parameters for HP-β-CD. The LC-MS/MS methods are ∼100-fold more sensitive than the current HPLC assay, and were successfully employed to analyze HP-β-CD in human plasma and CSF samples to support the phase 1 clinical trial of HP-β-CD in NPC1 patients. PMID:24868096
Jiang, Hui; Sidhu, Rohini; Fujiwara, Hideji; De Meulder, Marc; de Vries, Ronald; Gong, Yong; Kao, Mark; Porter, Forbes D; Yanjanin, Nicole M; Carillo-Carasco, Nuria; Xu, Xin; Ottinger, Elizabeth; Woolery, Myra; Ory, Daniel S; Jiang, Xuntian
2014-07-01
2-Hydroxypropyl-β-cyclodextrin (HP-β-CD), a widely used excipient for drug formulation, has emerged as an investigational new drug for the treatment of Niemann-Pick type C1 (NPC1) disease, a neurodegenerative cholesterol storage disorder. Development of a sensitive quantitative LC-MS/MS assay to monitor the pharmacokinetics (PKs) of HP-β-CD required for clinical trials has been challenging owing to the dispersity of the HP-β-CD. To support a phase 1 clinical trial for ICV delivery of HP-β-CD in NPC1 patients, novel methods for quantification of HP-β-CD in human plasma and cerebrospinal fluid (CSF) using LC-MS/MS were developed and validated: a 2D-LC-in-source fragmentation-MS/MS (2D-LC-IF-MS/MS) assay and a reversed phase ultra performance LC-MS/MS (RP-UPLC-MS/MS) assay. In both assays, protein precipitation and "dilute and shoot" procedures were used to process plasma and CSF, respectively. The assays were fully validated and in close agreement, and allowed determination of PK parameters for HP-β-CD. The LC-MS/MS methods are ∼100-fold more sensitive than the current HPLC assay, and were successfully employed to analyze HP-β-CD in human plasma and CSF samples to support the phase 1 clinical trial of HP-β-CD in NPC1 patients. Copyright © 2014 by the American Society for Biochemistry and Molecular Biology, Inc.
Zhang, Yanhua; Dufield, Dawn; Klover, Jon; Li, Wenlin; Szekely-Klepser, Gabriella; Lepsy, Christopher; Sadagopan, Nalini
2009-02-15
An LC-MS/MS method was developed and validated to quantify endogenous cyclic guanosine 3',5'-monophosphate (cGMP) in human plasma. The LC-MS/MS and competitive enzyme immunoassay (EIA) assays were compared. cGMP concentrations of 20 human plasma samples were measured by both methods. For the MS-based assay, plasma samples were subjected to a simple protein precipitation procedure by acetonitrile prior to analysis by electrospray ionization LC-MS/MS. De-protonated analytes generated in negative ionization mode were monitored through multiple reaction monitoring (MRM). A stable isotope-labeled internal standard, (13)C(10),(15)N(5)-cGMP, which was biosynthesized in-house, was used in the LC-MS/MS method. The competitive EIA was validated using a commercially available cGMP fluorescence assay kit. The intra-assay accuracy and precision for MS-based assay for cGMP were 6-10.1% CV and -3.6% to 7.3% relative error (RE), respectively, while inter-assay precision and accuracy were 5.6-8.1% CV and -2.1% to 6.3% RE, respectively. The intra-assay accuracy and precision for EIA were 17.9-27.1% CV and -4.9% to 24.5% RE, respectively, while inter-assay precision and accuracy were 15.1-39.5% CV and -30.8% to 4.37% RE, respectively. Near the lower limits of detection, there was little correlation between the cGMP concentration values in human plasma generated by these two methods (R(2)=0.197, P=0.05). Overall, the MS-based assay offered better selectivity, recovery, precision and accuracy over a linear range of 0.5-20ng/mL. The LC-MS/MS method provides an effective tool for the quantitation of cGMP to support clinical mechanistic studies of curative pharmaceuticals.
Simultaneous analysis of 17 diuretics in dietary supplements by HPLC and LC-MS/MS.
Woo, H; Kim, J W; Han, K M; Lee, J H; Hwang, I S; Lee, J H; Kim, J; Kweon, S J; Cho, S; Chae, K R; Han, S Y; Kim, J
2013-01-01
In order to test health foods for illegally added diuretics for weight loss, we developed simple, rapid, selective, and sensitive methods using HPLC and LC-MS/MS for the simultaneous analysis of 17 diuretics in dietary supplements. HPLC conditions were set with a Capcell-pak C18, using a mobile phase consisting of gradient conditions, UV detection at 254 nm and validated for linearity (r(2)> 0.999), precision (CV ≤ 3%), recoveries (90.4-102.8%) and reproducibility. Identification and quantification of 17 diuretics were accomplished by ion-spray LC-MS/MS using multiple reaction monitoring (MRM). The chromatographic separation was carried out under the reversed-phase mechanism on an HSS-T3 column. The LC-MS/MS method was validated for linearity (r(2)> 0.99) and precision (CV < 13%). Sixteen dietary supplements were tested with the developed methods. Diuretics were not detected in all samples. Extraction recovery was also investigated and the extraction recoveries in different formulations were from 88% to 110% and from 81% to 116% using HPLC and LC-MS/MS, respectively. There was no significant difference in recoveries in the type of dietary supplements. Based on this result, the developed methods to monitor illegal drug adulterations in dietary supplements using HPLC and LC-MS/MS are simple, fast and reliable. Therefore, it is applicable to routine drug-adulteration screening.
Analytical Stability-Indicating Methods for Alogliptin in Tablets by LC-CAD and LC-UV.
Bertol, Charise Dallazem; Friedrich, Maria Tereza; Carlos, Graciela; Froehlich, Pedro Eduardo
2017-03-01
Stability-indicating LC methods using a UV detector and a charged aerosol detector (CAD) simultaneously were validated for the assessment of alogliptin (ALG) in tablets. The analysis was performed on a C8 column (250 × 4.6 mm, 5 μm) at a flow of 0.8 mL/min, using acetonitrile-10 mM ammonium acetate buffer (pH 3.5; 90 + 10, v/v) as mobile phase and UV detection at 275 nm. Validation followed the International Conference on Harmonization guidelines. The method was linear over the range of 25-200 μg/mL. Normality of the residuals showed a normal distribution, no autocorrelation, and homoscedasticity. LODs were 6.25 and 2.65 µg/mL and LOQs were 20.85 and 8.84 µg/mL for the CAD and the UV detector, respectively. The methods were precise and accurate. Excipients and degradation products did not interfere in the methods in studies of specificity. None of the factors studied in the analysis of robustness had a significant effect on the quantification of the ALG by the Pareto chart. The results of the assay obtained with LC-CAD and LC-UV were similar. The methods could be considered interchangeable and stability-indicating, and can be applied as an appropriate QC tool for analysis of ALG in tablets.
Noegrohati, Sri; Hernadi, Elan; Asviastuti, Syanti
2018-06-01
Production of red flesh dragon fruit (Hylocereus polyrhizus) was hampered by Colletotrichum sp. Pre-harvest application of azoxystrobin and difenoconazole mixture is recommended, therefore, a selective and sensitive multi residues analytical method is required in monitoring and evaluating the commodity's safety. LC-MS/MS is a well-established analytical technique for qualitative and quantitative determination in complex matrices. However, this method is hurdled by co-eluted coextractives interferences. This work evaluated the pH effect of acetate buffered and citrate buffered QuEChERS sample preparation in their effectiveness of matrix effect reduction. Citrate buffered QuEChERS proved to produce clean final extract with relative matrix effect 0.4%-0.7%. Method validation of the selected sample preparation followed by LC-MS/MS for whole dragon fruit, flesh and peel matrices fortified at 0.005, 0.01, 0.1 and 1 g/g showed recoveries 75%-119%, intermediate repeatability 2%-14%. The expanded uncertainties were 7%-48%. Based on the international acceptance criteria, this method is valid.
Rhea, Jeanne M; French, Deborah; Molinaro, Ross J
2013-05-01
To develop and validate liquid chromatography tandem mass spectrometry (LC-MS/MS) methods for the direct measurement of total and free testosterone in patient samples on two different analytical systems. An API 4000 and 5000 triple quadropoles were used and compared; the former is reported to be 3-5 times less sensitive, as was used to set the quantitation limits. Free testosterone was separated from the protein-bound fraction by equilibrium dialysis followed by derivatization. Either free or total testosterone, and a deuterated internal standard (d3-testosterone) were extracted by liquid-liquid extraction. The validation results were compared to two different clinical laboratories. The use of d2-testosterone was found to be unacceptable for our method. The total testosterone LC-MS/MS methods on both systems were linear over a wide concentration range of 1.5-2000ng/dL. Free testosterone was measured directly using equilibrium dialysis coupled LC-MS/MS and linear over the concentration range of 2.5-2500pg/mL. Good correlation (total testosterone, R(2)=0.96; free testosterone, R(2)=0.98) was observed between our LC-MS/MS systems and comparator laboratory. However, differences in absolute values for both free and total testosterone measurements were observed while a comparison to a second published LC-MS/MS method showed excellent correlation. Free and total testosterone measurements correlated well with clinical observations. To our knowledge, this is the first published validation of free and total testosterone methods across two analytical systems of different analytical sensitivities. A less sensitive system does not sacrifice analytical or clinical sensitivity to directly measure free and total testosterone in patient samples. Copyright © 2013 The Canadian Society of Clinical Chemists. Published by Elsevier Inc. All rights reserved.
Lei, Q Paula; Lamb, David H; Shannon, Anthony G; Cai, Xinxing; Heller, Ronald K; Huang, Michael; Zablackis, Earl; Ryall, Robert; Cash, Patricia
2004-12-25
An LC-MS/MS method for determination of the break down product of N-ethyl-N'-(3-dimethylaminopropyl) carbodiimide (EDC) urea derivative, EDU, has been developed and validated for monitoring the residual coupling reagents. Results indicate that the method exhibits suitable specificity, sensitivity, precision, linearity and accuracy for quantification of residual EDU in the presence of meningococcal polysaccharide-diphtheria toxoid conjugate vaccine and other vaccine matrix compounds. The assay has been validated for a detection range of 10-100 ng/mL and then successfully transferred to quality control (QC) lab. This same method has also been applied to the determination of residual diaminohexane (DAH) in the presence of EDU. LC-MS/MS has proven to be useful as a quick and sensitive approach for simultaneous determination of multiple residual compounds in glycoconjugate vaccine samples.
Zhang, Jie; Wei, Shimin; Ayres, David W; Smith, Harold T; Tse, Francis L S
2011-09-01
Although it is well known that automation can provide significant improvement in the efficiency of biological sample preparation in quantitative LC-MS/MS analysis, it has not been widely implemented in bioanalytical laboratories throughout the industry. This can be attributed to the lack of a sound strategy and practical procedures in working with robotic liquid-handling systems. Several comprehensive automation assisted procedures for biological sample preparation and method validation were developed and qualified using two types of Hamilton Microlab liquid-handling robots. The procedures developed were generic, user-friendly and covered the majority of steps involved in routine sample preparation and method validation. Generic automation procedures were established as a practical approach to widely implement automation into the routine bioanalysis of samples in support of drug-development programs.
Stypulkowska, Karolina; Fijalek, Zbigniew; Sarna, Katarzyna
2010-01-01
A new, simple and repeatable liquid chromatography method with charged aerosol detection (LC-CAD) for the determination of gentamicin sulphate composition and related substances has been developed. Gentamicin lacks of chromophores, therefore its determination is quite problematic. Using a universal CAD enables to achieve good separation without sample derivatization. Mass spectrometry was employed to confirm the LC-CAD peak profile. The proposed method was validated and applied for the determination of gentamicin sulphate composition and related substances in pharmaceutical preparations. PMID:21212825
Kim, Borahm; Lee, Mi Na; Park, Hyung Doo; Kim, Jong Won; Chang, Yun Sil; Park, Won Soon; Lee, Soo Youn
2015-11-01
Conventional screening for congenital adrenal hyperplasia (CAH) using immunoassays generates a large number of false-positive results. A more specific liquid chromatography-tandem mass spectrometry (LC-MS/MS) method has been introduced to minimize unnecessary follow-ups. However, because of limited data on its use in the Korean population, LC-MS/MS has not yet been incorporated into newborn screening programs in this region. The present study aims to develop and validate an LC-MS/MS method for the simultaneous determination of seven steroids in dried blood spots (DBS) for CAH screening, and to define age-specific reference intervals in the Korean population. We developed and validated an LC-MS/MS method to determine the reference intervals of cortisol, 17-hydroxyprogesterone, 11-deoxycortisol, 21-deoxycortisol, androstenedione, corticosterone, and 11-deoxycorticosterone simultaneously in 453 DBS samples. The samples were from Korean subjects stratified by age group (78 full-term neonates, 76 premature neonates, 89 children, and 100 adults). The accuracy, precision, matrix effects, and extraction recovery were satisfactory for all the steroids at three concentrations; values of intra- and inter-day precision coefficients of variance, bias, and recovery were 0.7-7.7%, -1.5-9.8%, and 49.3-97.5%, respectively. The linearity range was 1-100 ng/mL for cortisol and 0.5-50 ng/mL for other steroids (R²>0.99). The reference intervals were in agreement with the previous reports. This LC-MS/MS method and the reference intervals validated in the Korean population can be successfully applied to analyze seven steroids in DBS for the diagnosis of CAH.
Neiens, Patrick; De Simone, Angela; Ramershoven, Anna; Höfner, Georg; Allmendinger, Lars; Wanner, Klaus T
2018-03-03
MS Binding Assays represent a label-free alternative to radioligand binding assays. In this study, we present an LC-ESI-MS/MS method for the quantification of (R,R)-4-(2-benzhydryloxyethyl)-1-(4-fluorobenzyl)piperidin-3-ol [(R,R)-D-84, (R,R)-1], (S,S)-reboxetine [(S,S)-2], and (S)-citalopram [(S)-3] employed as highly selective nonlabeled reporter ligands in MS Binding Assays addressing the dopamine [DAT, (R,R)-D-84], norepinephrine [NET, (S,S)-reboxetine] and serotonin transporter [SERT, (S)-citalopram], respectively. The developed LC-ESI-MS/MS method uses a pentafluorphenyl stationary phase in combination with a mobile phase composed of acetonitrile and ammonium formate buffer for chromatography and a triple quadrupole mass spectrometer in the multiple reaction monitoring mode for mass spectrometric detection. Quantification is based on deuterated derivatives of all three analytes serving as internal standards. The established LC-ESI-MS/MS method enables fast, robust, selective and highly sensitive quantification of all three reporter ligands in a single chromatographic run. The method was validated according to the Center for Drug Evaluation and Research (CDER) guideline for bioanalytical method validation regarding selectivity, accuracy, precision, calibration curve and sensitivity. Finally, filtration-based MS Binding Assays were performed for all three monoamine transporters based on this LC-ESI-MS/MS quantification method as read out. The affinities determined in saturation experiments for (R,R)-D-84 toward hDAT, for (S,S)-reboxetine toward hNET, and for (S)-citalopram toward hSERT, respectively, were in good accordance with results from literature, clearly demonstrating that the established MS Binding Assays have the potential to be an efficient alternative to radioligand binding assays widely used for this purpose so far. Copyright © 2018 John Wiley & Sons, Ltd.
USDA-ARS?s Scientific Manuscript database
Prior to conducting a collaborative study of AOAC First Action 2012.25 LC-MS/MS analytical method for the determination of residues of three triphenylmethane dyes (malachite green, crystal violet, and brilliant green) and their metabolites (leucomalachite green and leucocrystal violet) in seafood, a...
Zimmermann, Estevan Sonego; da Silva, Lucélia Magalhães; Calegari, Guilherme Zanini; Stamm, Fernanda Pavani; Souto, Ricardo Bizogne; Dalmora, Sérgio Luiz
2013-01-01
A size-exclusion LC method was validated for the determination of interferon-a2a (rhlFN-alpha2a) in pharmaceutical formulations without interference from human serum albumin. Chromatographic separation was performed on a BioSep-SEC-S 2000 column (300 x 7.8 mm id). The mobile phase consisted of 0.001 M monobasic potassium phosphate, 0.008 M sodium phosphate dibasic; 0.2 M sodium chloride buffer, pH 7.4, run at a gradient flow rate and using photodiode array detection at 214 nm, was used. Chromatographic separation was achieved with a retention time of 17.2 min, and the analysis was linear over the concentration range of 1.98 to 198 microg/mL (r2 = 0.9996). The accuracy was 101.39%, with bias lower than 1.67%. The LOD and LOQ were 0.87 and 1.98 microg/mL, respectively. Moreover, method validation demonstrated acceptable results for precision and robustness. The method was applied to the assessment of rhlFN-alpha2a and related proteins in biopharmaceutical dosage forms, and the content/potencies were correlated to those given by a validated RP-LC method and an in vitro bioassay. It was concluded that use of the methods in conjunction allows a great improvement in monitoring stability and QC, thereby ensuring the therapeutic efficacy of the biotechnology-derived medicine.
Ok, Hyun Ee; Tian, Fei; Hong, Eun Young; Paek, Ockjin; Kim, Sheen-Hee; Kim, Dongsul; Chun, Hyang Sook
2016-01-01
An interlaboratory study was performed in eight laboratories to validate a liquid chromatography–tandem mass spectrometry (LC/MS/MS) method for the simultaneous determination of aflatoxins and sterigmatocystin (STC) in white rice and sorghum (Sorghum bicolor). Fortified samples (at three different levels) of white rice and sorghum were extracted, purified through a solid-phase extraction (SPE) column, and then analyzed by LC/MS/MS. The apparent recoveries (ARs) ranged from 78.8% to 95.0% for aflatoxins and from 85.3% to 96.7% for STC. The relative standard deviations for repeatability (RSDr) and reproducibility (RSDR) of aflatoxins were in the ranges 7.9%–33.8% and 24.4%–81.0%, respectively. For STC, the RSDr ranged from 7.1% to 40.2% and the RSDR ranged from 28.1% to 99.2%. The Horwitz ratio values for the aflatoxins and STC ranged from 0.4 to 1.2 in white rice and from 0.3 to 1.0 in sorghum, respectively. These results validated this method for the simultaneous determination of aflatoxins and STC by LC/MS/MS after SPE column cleanup. The percentages of satisfactory Z-score values (|Z| ≤ 2) were the following: for white rice, 100% for aflatoxins and STC; for sorghum, 100%, except in data from two laboratories for STC (0.3 μg/kg). This validated that the LC/MS/MS method was successfully applied for the determination of aflatoxins and STC in 20 white rice and 20 sorghum samples sourced from Korean markets. PMID:27983588
Frey, Alexander J; Wang, Qingqing; Busch, Christine; Feldman, Daniel; Bottalico, Lisa; Mesaros, Clementina A; Blair, Ian A; Vachani, Anil; Snyder, Nathaniel W
2016-12-01
A multiplexed quantitative method for the analysis of three major unconjugated steroids in human serum by stable isotope dilution liquid chromatography-high resolution mass spectrometry (LC-HRMS) was developed and validated on a Q Exactive Plus hybrid quadrupole/Orbitrap mass spectrometer. This quantification utilized isotope dilution and Girard P derivatization on the keto-groups of testosterone (T), androstenedione (AD) and dehydroepiandrosterone (DHEA) to improve ionization efficiency using electrospray ionization. Major isomeric compounds to T and DHEA; the inactive epimer of testosterone (epiT), and the metabolite of AD, 5α-androstanedione (5α-AD) were completely resolved on a biphenyl column within an 18min method. Inter- and intra-day method validation using LC-HRMS with qualifying product ions was performed and acceptable analytical performance was achieved. The method was further validated by comparing steroid levels from 100μL of serum from young vs older subjects. Since this approach provides high-dimensional HRMS data, untargeted analysis by age group was performed. DHEA and T were detected among the top analytes most significantly different across the two groups after untargeted LC-HRMS analysis, as well as a number of other still unknown metabolites, indicating the potential for combined targeted/untargeted analysis in steroid analysis. Copyright © 2016 Elsevier Inc. All rights reserved.
Urine Multi-drug Screening with GC-MS or LC-MS-MS Using SALLE-hybrid PPT/SPE.
Lee, Junhui; Park, Jiwon; Go, Ahra; Moon, Heesung; Kim, Sujin; Jung, Sohee; Jeong, Wonjoon; Chung, Heesun
2018-05-14
To intoxicated patients in the emergency room, toxicological analysis can be considerably helpful for identifying the involved toxicants. In order to develop a urine multi-drug screening (UmDS) method, gas chromatography-mass spectrometry (GC-MS) and liquid chromatography-tandem mass spectrometry (LC-MS-MS) were used to determine targeted and unknown toxicants in urine. A GC-MS method in scan mode was validated for selectivity, limit of detection (LOD) and recovery. An LC-MS-MS multiple reaction monitoring (MRM) method was validated for lower LOD, recovery and matrix effect. The results of the screening analysis were compared with patient medical records to check the reliability of the screen. Urine samples collected from an emergency room were extracted through a combination of salting-out assisted liquid-liquid extraction (SALLE) and hybrid protein precipitation/solid phase extraction (hybrid PPT/SPE) plates and examined by GC-MS and LC-MS-MS. GC-MS analysis was performed as unknown drug screen and LC-MS-MS analysis was conducted as targeted drug screen. After analysis by GC-MS, a library search was conducted using an in-house library established with the automated mass spectral deconvolution and identification system (AMDISTM). LC-MS-MS used Cliquid®2.0 software for data processing and acquisition in MRM mode. An UmDS method by GC-MS and LC-MS-MS was developed by using a SALLE-hybrid PPT/SPE and in-house library. The results of UmDS by GC-MS and LC-MS-MS showed that toxicants could be identified from 185 emergency room patient samples containing unknown toxicants. Zolpidem, acetaminophen and citalopram were the most frequently encountered drugs in emergency room patients. The UmDS analysis developed in this study can be used effectively to detect toxic substances in a short time. Hence, it could be utilized in clinical and forensic toxicology practices.
Simithy, Johayra; Gill, Gobind; Wang, Yu; Goodwin, Douglas C; Calderón, Angela I
2015-02-17
A simple and reliable liquid chromatography-mass spectrometry (LC-MS) assay has been developed and validated for the kinetic characterization and evaluation of inhibitors of shikimate kinase from Mycobacterium tuberculosis (MtSK), a potential target for the development of novel antitubercular drugs. This assay is based on the direct determination of the reaction product shikimate-3-phosphate (S3P) using electrospray ionization (ESI) and a quadrupole time-of-flight (Q-TOF) detector. A comparative analysis of the kinetic parameters of MtSK obtained by the LC-MS assay with those obtained by a conventional UV-assay was performed. Kinetic parameters determined by LC-MS were in excellent agreement with those obtained from the UV assay, demonstrating the accuracy, and reliability of this method. The validated assay was successfully applied to the kinetic characterization of a known inhibitor of shikimate kinase; inhibition constants and mode of inhibition were accurately delineated with LC-MS.
Glauser, Gaétan; Grund, Baptiste; Gassner, Anne-Laure; Menin, Laure; Henry, Hugues; Bromirski, Maciej; Schütz, Frédéric; McMullen, Justin; Rochat, Bertrand
2016-03-15
A paradigm shift is underway in the field of quantitative liquid chromatography-mass spectrometry (LC-MS) analysis thanks to the arrival of recent high-resolution mass spectrometers (HRMS). The capability of HRMS to perform sensitive and reliable quantifications of a large variety of analytes in HR-full scan mode is showing that it is now realistic to perform quantitative and qualitative analysis with the same instrument. Moreover, HR-full scan acquisition offers a global view of sample extracts and allows retrospective investigations as virtually all ionized compounds are detected with a high sensitivity. In time, the versatility of HRMS together with the increasing need for relative quantification of hundreds of endogenous metabolites should promote a shift from triple-quadrupole MS to HRMS. However, a current "pitfall" in quantitative LC-HRMS analysis is the lack of HRMS-specific guidance for validated quantitative analyses. Indeed, false positive and false negative HRMS detections are rare, albeit possible, if inadequate parameters are used. Here, we investigated two key parameters for the validation of LC-HRMS quantitative analyses: the mass accuracy (MA) and the mass-extraction-window (MEW) that is used to construct the extracted-ion-chromatograms. We propose MA-parameters, graphs, and equations to calculate rational MEW width for the validation of quantitative LC-HRMS methods. MA measurements were performed on four different LC-HRMS platforms. Experimentally determined MEW values ranged between 5.6 and 16.5 ppm and depended on the HRMS platform, its working environment, the calibration procedure, and the analyte considered. The proposed procedure provides a fit-for-purpose MEW determination and prevents false detections.
Sato, Tamaki; Miyamoto, Iori; Uemura, Masako; Nakatani, Tadashi; Kakutani, Naoya; Yamano, Tetsuo
2016-01-01
A validation study was carried out on a rapid method for the simultaneous determination of pesticide residues in vegetables and fruits by LC-MS/MS. Preparation of the test solution was performed by a solid-phase extraction technique with QuEChERS (STQ method). Pesticide residues were extracted with acetonitrile using a homogenizer, followed by salting-out and dehydration at the same time. The acetonitrile layer was purified with C18 and PSA mini-columns. The method was assessed for 130 pesticide residues in 14 kinds of vegetables and fruits at the concentration level of 0.01 μg/g according to the method validation guideline of the Ministry of Health, Labour and Welfare of Japan. As a result 75 to 120 pesticide residues were determined satisfactorily in the tested samples. Thus, this method could be useful for a rapid and simultaneous determination of multi-class pesticide residues in various vegetables and fruits.
Wang, Zhenyu; Li, Shiming; Ferguson, Stephen; Goodnow, Robert; Ho, Chi-Tang
2008-01-01
Polymethoxyflavones (PMFs), which exist exclusively in the citrus genus, have biological activities including anti-inflammatory, anticarcinogenic, and antiatherogenic properties. A validated RPLC method was developed for quantitative analysis of six major PMFs, namely nobiletin, tangeretin, sinensetin, 5,6,7,4'-tetramethoxyflavone, 3,5,6,7,3',4'-hexamethoxyflavone, and 3,5,6,7,8,3',4'-heptamethoxyflavone. The polar embedded LC stationary phase was able to fully resolve the six analogues. The developed method was fully validated in terms of linearity, accuracy, precision, sensitivity, and system suitability. The LOD of the method was calculated as 0.15 microg/mL and the recovery rate was between 97.0 and 105.1%. This analytical method was successfully applied to quantify the individual PMFs in four commercially available citrus peel extracts (CPEs). Each extract shows significant difference in the PMF composition and concentration. This method may provide a simple, rapid, and reliable tool to help reveal the correlation between the bioactivity of the PMF extracts and the individual PMF content.
Gören, Ahmet C; Bilsel, Gökhan; Şimşek, Adnan; Bilsel, Mine; Akçadağ, Fatma; Topal, Kevser; Ozgen, Hasan
2015-05-15
High Performance Liquid Chromatography LC-UV and LC-MS/MS methods were developed and validated for quantitative analyses of sodium benzoate and potassium sorbate in foods and beverages. HPLC-UV and LC-MS/MS methods were compared for quantitative analyses of sodium benzoate and potassium sorbate in a representative ketchup sample. Optimisation of the methods enabled the chromatographic separation of the analytes in less than 4 min. A correlation coefficient of 0.999 was achieved over the measured calibration range for both compounds and methods (HPLC and LC-MS/MS). The uncertainty values of sodium benzoate and potassium sorbate were found as 0.199 and 0.150 mg/L by HPLC and 0.072 and 0.044 mg/L by LC-MS/MS, respectively. Proficiency testing performance of Turkish accredited laboratories between the years 2005 and 2013 was evaluated and reported herein. The aim of the proficiency testing scheme was to evaluate the performance of the laboratories, analysing benzoate and sorbate in tomato ketchup. Copyright © 2014 Elsevier Ltd. All rights reserved.
USDA-ARS?s Scientific Manuscript database
An LC-MS/MS method was developed and validated to determine 7alpha-OH cholesterol in liver microsome. This method was convenient and fast with high specificity and sensitivity. Briefly, a gradient elution was performed on a Synergi polar-C18 column (50 x 4.6mm i.d., 3microm). The mobile phase (cons...
van Dooren, Ines; Foubert, Kenn; Theunis, Mart; Naessens, Tania; Pieters, Luc; Apers, Sandra
2018-01-30
The berries of Vaccinium macrocarpon, cranberry, are widely used for the prevention of urinary tract infections. This species contains A-type proanthocyanidins (PACs), which intervene in the initial phase of the development of urinary tract infections by preventing the adherence of Escherichia coli by their P-type fimbriae to uroepithelial cells. Unfortunately, the existing clinical studies used different cranberry preparations, which were poorly standardized. Because of this, the results were hard to compare, which led sometimes to conflicting results. Currently, PACs are quantified using the rather non-specific spectrophotometric 4-dimethylaminocinnamaldehyde (DMAC) method. In addition, a normal phase HPTLC-densitometric method, a HPLC-UV method and three LC-MS/MS methods for quantification of procyanidin A2 were recently published. All these methods contain some shortcomings and errors. Hence, the development and validation of a fast and sensitive standard addition LC-MS/MS method for the simultaneous quantification of A-type dimers and trimers in a cranberry dry extract was carried out. A linear calibration model could be adopted for dimers and, after logaritmic transformation, for trimers. The maximal interday and interconcentration precision was found to be 4.86% and 4.28% for procyanidin A2, and 5.61% and 7.65% for trimeric PACs, which are all acceptable values for an analytical method using LC-MS/MS. In addition, twelve different cranberry extracts were analyzed by means of the newly validated method and other widely used methods. There appeared to be an enormous variation in dimeric and trimeric PAC content. Comparison of these results with LC-MS/MS analysis without standard addition showed the presence of matrix effects for some of the extracts and proved the necessity of standard addition. A comparison of the well-known and widely used DMAC method, the butanol-HCl assay and this newly developed LC-MS/MS method clearly indicated the need for a reliable method able to quantify A-type PACs, which are considered to be the pharmacologically active constituents of cranberry, since neither the DMAC or butanol-HCl assays are capable of distinguishing between A and B-type PACs and therefore cannot detect adulterations with, for example, extracts with a high B-type PAC content. Hence, the combination of the DMAC method or butanol-HCl assay with this more specific LC-MS/MS assay could overcome these shortcomings. Copyright © 2017 Elsevier B.V. All rights reserved.
Carter, Melissa D.; Calcutt, M. Wade; Malow, Beth A.; Rose, Kristie L.; Hachey, David L.
2012-01-01
Melatonin (MEL) and its chemical precursor N-acetylserotonin (NAS) are believed to be potential biomarkers for sleep-related disorders. Measurement of these compounds, however, has proven to be difficult due to their low circulating levels, especially that of NAS. Few methods offer the sensitivity, specificity and dynamic range needed to monitor MEL and its precursors and metabolites in small blood samples, such as those obtained from pediatric patients. In support of our ongoing study to determine the safety, tolerability, and PK dosing strategies for MEL in treating insomnia in children with autism spectrum disorder, two highly sensitive LC-MS/MS assays were developed for the quantitation of MEL and precursor NAS at pg/mL levels in small volumes of human plasma. A validated electrospray ionization (ESI) method was used to quantitate high levels of MEL in PK studies and a validated nanospray (nESI) method was developed for quantitation of MEL and NAS at endogenous levels. In both assays plasma samples were processed by centrifugal membrane dialysis after addition of stable isotopic internal standards, and the components were separated by either conventional LC using a Waters SymmetryShield RP18 column (2.1×100 mm, 3.5 μm) or on a polyimide-coated, fused-silica capillary self-packed with 17 cm AquaC18 (3 μm, 125 Å). Quantitation was done using the SRM transitions m/z 233→174 and m/z 219→160 for MEL and NAS, respectively. The analytical response ratio vs. concentration curves were linear for MEL (nanoflow LC: 11.7–1165 pg/mL, LC: 1165–116500 pg/mL) and for NAS (nanoflow LC: 11.0–1095 pg/mL). PMID:22431453
NASA Astrophysics Data System (ADS)
Gupta, Lokesh Kumar
2012-11-01
Seven process related impurities were identified by LC-MS in the atorvastatin calcium drug substance. These impurities were identified by LC-MS. The structure of impurities was confirmed by modern spectroscopic techniques like 1H NMR and IR and physicochemical studies conducted by using synthesized authentic reference compounds. The synthesized reference samples of the impurity compounds were used for the quantitative HPLC determination. These impurities were detected by newly developed gradient, reverse phase high performance liquid chromatographic (HPLC) method. The system suitability of HPLC analysis established the validity of the separation. The analytical method was validated according to International Conference of Harmonization (ICH) with respect to specificity, precision, accuracy, linearity, robustness and stability of analytical solutions to demonstrate the power of newly developed HPLC method.
Ananthula, Suryatheja; Janagam, Dileep R; Jamalapuram, Seshulatha; Johnson, James R; Mandrell, Timothy D; Lowe, Tao L
2015-10-15
Rapid, sensitive, selective and accurate LC/MS/MS method was developed for quantitative determination of levonorgestrel (LNG) in rat plasma and further validated for specificity, linearity, accuracy, precision, sensitivity, matrix effect, recovery efficiency and stability. Liquid-liquid extraction procedure using hexane:ethyl acetate mixture at 80:20 v:v ratio was employed to efficiently extract LNG from rat plasma. Reversed phase Luna column C18(2) (50×2.0mm i.d., 3μM) installed on a AB SCIEX Triple Quad™ 4500 LC/MS/MS system was used to perform chromatographic separation. LNG was identified within 2min with high specificity. Linear calibration curve was drawn within 0.5-50ng·mL(-1) concentration range. The developed method was validated for intra-day and inter-day accuracy and precision whose values fell in the acceptable limits. Matrix effect was found to be minimal. Recovery efficiency at three quality control (QC) concentrations 0.5 (low), 5 (medium) and 50 (high) ng·mL(-1) was found to be >90%. Stability of LNG at various stages of experiment including storage, extraction and analysis was evaluated using QC samples, and the results showed that LNG was stable at all the conditions. This validated method was successfully used to study the pharmacokinetics of LNG in rats after SubQ injection, providing its applicability in relevant preclinical studies. Copyright © 2015 Elsevier B.V. All rights reserved.
Determination of aliskiren in tablet dosage forms by a validated stability-indicating RP-LC method.
Wrasse-Sangoi, M; Sangoi, M S; Oliveira, P R; Secretti, L T; Rolim, C M B
2011-02-01
A reversed-phase liquid chromatography (RP-LC) method is validated for the determination of aliskiren in tablet dosage form. The LC method is carried out on a Waters XBridge C(18) column (150 × 4.6 mm i.d.), maintained at 25°C. The mobile phase consisted of acetonitrile:water (95:5, v/v)/phosphoric acid (25 mM, pH 3.0) (40:60, v/v), run at a flow rate of 1.0 mL/min, with photodiode array detector set at 229 nm. The chromatographic separation is obtained with aliskiren retention time of 3.68 min, and it is linear in the range of 10-300 μg/mL (r = 0.9999). The limits of detection and quantitation are 2.38 and 7.93 μg/mL, respectively. The specificity and stability-indicating capability of the method are proven through degradation studies, which also showed that there is no interference of the formulation excipients, showing that peak is free from any coeluting peak. The method showed adequate precision, with a relative standard deviation (RSD) values lower than 0.92%. Good values of accuracy were also obtained, with a mean value of 99.55%. Experimental design is used during validation to calculate method robustness. The proposed method is applied for the analysis of the tablet dosage forms, contributing to improve the quality control and to assure the therapeutic efficacy.
Hessling, Bernd; Büttner, Knut; Hecker, Michael; Becher, Dörte
2013-10-01
Quantitative LC-MALDI is an underrepresented method, especially in large-scale experiments. The additional fractionation step that is needed for most MALDI-TOF-TOF instruments, the comparatively long analysis time, and the very limited number of established software tools for the data analysis render LC-MALDI a niche application for large quantitative analyses beside the widespread LC-electrospray ionization workflows. Here, we used LC-MALDI in a relative quantification analysis of Staphylococcus aureus for the first time on a proteome-wide scale. Samples were analyzed in parallel with an LTQ-Orbitrap, which allowed cross-validation with a well-established workflow. With nearly 850 proteins identified in the cytosolic fraction and quantitative data for more than 550 proteins obtained with the MASCOT Distiller software, we were able to prove that LC-MALDI is able to process highly complex samples. The good correlation of quantities determined via this method and the LTQ-Orbitrap workflow confirmed the high reliability of our LC-MALDI approach for global quantification analysis. Because the existing literature reports differences for MALDI and electrospray ionization preferences and the respective experimental work was limited by technical or methodological constraints, we systematically compared biochemical attributes of peptides identified with either instrument. This genome-wide, comprehensive study revealed biases toward certain peptide properties for both MALDI-TOF-TOF- and LTQ-Orbitrap-based approaches. These biases are based on almost 13,000 peptides and result in a general complementarity of the two approaches that should be exploited in future experiments.
van der Heeft, E; Dijkman, E; Baumann, R A; Hogendoorn, E A
2000-05-19
The performance of mass spectrometric (MS) detection and UV detection in combination with reversed-phase liquid chromatography without and with the use of coupled column RPLC (LC-LC) has been compared for the trace analysis of phenylurea herbicides in environmental waters. The selected samples of this comparative study originated from an inter-laboratory study. For both detection modes, a 50 mm x 4.6 mm I.D. column and a 100 mm x 4.6 mm I.D. column packed with 3 microm C18 were used as the first (C-1) and second (C-2) column, respectively. Atmospheric pressure chemical ionization mass spectrometry was performed on a magnetic sector instrument. The LC-LC-MS analysis was carried out on-line by means of direct large volume (11.7 ml) injection (LVI). The performance of both on-line (LVI, 4 ml of sample) and off-line LC-LC-UV (244 nm) analysis was investigated. The latter procedure consisted of a solid-phase extraction (SPE) of 250 ml of water sample on a 500 mg C18 cartridge. The comparative study showed that LC-LC-MS is more selective then LC-LC-UV and, in most cases, more sensitive. The LVI-LC-LC-MS approach combines direct quantification and confirmation of most of the analytes down to a level of 0.01 microg/l in water samples in less then 30 min. As regards LC-LC-UV, the off-line method appeared to be a more viable approach in comparison with the on-line procedure. This method allows the screening of phenylurea's in various types of water samples down to a level of at least 0.05 microg/l. On-line analysis with LVI provided marginal sensitivity (limits of detection of about 0.1 microg/l) and selectivity was sometimes less in case of surface water samples. Both the on-line LVI-LC-LC-MS method and the LC-LC-UV method using off-line SPE were validated by analysing a series of real-life reference samples. These samples were part of an inter-laboratory test and contained residues of herbicides ranging from 0.02 to 0.8 microg/l. Beside good correlation between the methods the data agreed very well with the true values of the samples.
Lee, Ji Hyun; Kang, Gihaeng; Park, Han Na; Kim, Jihee; Kim, Nam Sook; Park, Seongsoo; Park, Sung-Kwan; Baek, Sun Young; Kang, Hoil
2018-02-01
In this study, we developed a UPLC-PDA and LC-Q-TOF/MS method to identify and measure the following prohibited substances that may be found in dietary supplements:triaminodil, minoxidil, bimatoprost, alimemazine, diphenylcyclopropenone, α-tradiol, finasteride, methyltestosterone, spironolatone, flutamide, cyproterone, dutasteride, and testosterone 17-propionate.The method was validated according to International Conference on Harmonization guidelines in terms of specificity, linearity, accuracy, precision, LOD, LOQ, recovery, and stability. The method was completely validated showing satisfactory data for all method validation parameters. The linearity was good (R 2 > 0.999) with intra- and inter-day precision values of 0.2-3.4% and 0.3-2.9%, respectively. Moreover, the intra- and inter-day accuracies were 87-102% and 86-103%, respectively, and the precision was better than 9.4% (relative standard deviation).Hence, the proposed method is precise and has high quality,and can be utilised to comprehensively and continually monitor illegal drug adulteration in various forms of dietary supplements. Furthermore, to evaluate the applicability of the proposed method, we analysed 13 hair-growth compounds in 78 samples including food and dietary supplements. Minoxidil and triaminodil were detected in capsules at concentrations of 4.69 mg/g and 6.54 mg/g. In addition, finasteride was detected in a tablet at 13.45 mg/g. In addition, the major characteristic fragment ions were confirmed once again using LC-Q-TOF/MS for higher accuracy.
Ramisetti, Nageswara Rao; Kuntamukkala, Ramakrishna; Lakshetti, Sridhar; Sripadi, Prabhakar
2014-07-01
The current study dealt with the degradation behavior of lacosamide (LAC) under ICH prescribed stress conditions. LAC was found to be labile under acid and base hydrolytic stress conditions, while it was stable to neutral hydrolytic, oxidative, photolytic and thermal stress. In total, seven degradation products (DPs) were formed, which were separated on a C18 column using a stability-indicating method. LC-MS analyses indicated that one of the DPs had the same molecular mass as that of the drug. Structural characterization of DPs was carried out using ESI-Q-TOF-MS/MS technique. The degradation pathways and mechanisms of degradation of the drug were delineated by carrying out the degradation in different co-solvents viz. methanol, deuterated methanol, ethanol, 1-propanol and acetonitrile. The developed LC method was validated for the determination of related substances and assay of LAC as per ICH guidelines. This study demonstrates a comprehensive approach of LAC degradation studies during its development phase. Copyright © 2014. Published by Elsevier B.V.
Determination of chlormequat in pig serum and sow milk by LC-MS/MS.
Poulsen, M E; Christensen, H B; Sørensen, M T; Leffers, H; Andersen, J H
2007-11-01
Chlormequat is a plant growth regulator widely used on cereals, and there is general concern that it may impair human fertility. A LC-MS/MS method for the analysis of chlormequat in milk and serum was developed and validated in connection with an investigation on the effect of chlormequat on pig reproduction. Validation of the method was based on recovery tests at three spiking levels, determined as double determinations and repeated at least four times. Samples were extracted with methanol-water-acetic acid, centrifuged, filtrated and determined by LC-MS/MS. The mean recoveries were in the range 80-110%, and the LOD was 0.2 ng/g for serum and 0.3 ng/g for milk. The values for repeatability and reproducibility were within 2/3 of the limits given by the Horwitz equation. Samples of pig serum (59) and sow milk (27) were analyzed using the method. Chlormequat was determined in four milk samples in the range of 0.4 ng/g to 1.2 ng/g and in all serum samples in the range of 0.2 ng/g-4.0 ng/g.
Quantitative Method for Simultaneous Analysis of Acetaminophen and 6 Metabolites.
Lammers, Laureen A; Achterbergh, Roos; Pistorius, Marcel C M; Romijn, Johannes A; Mathôt, Ron A A
2017-04-01
Hepatotoxicity after ingestion of high-dose acetaminophen [N-acetyl-para-aminophenol (APAP)] is caused by the metabolites of the drug. To gain more insight into factors influencing susceptibility to APAP hepatotoxicity, quantification of APAP and metabolites is important. A few methods have been developed to simultaneously quantify APAP and its most important metabolites. However, these methods require a comprehensive sample preparation and long run times. The aim of this study was to develop and validate a simplified, but sensitive method for the simultaneous quantification of acetaminophen, the main metabolites acetaminophen glucuronide and acetaminophen sulfate, and 4 Cytochrome P450-mediated metabolites by using liquid chromatography with mass spectrometric (LC-MS) detection. The method was developed and validated for the human plasma, and it entailed a single method for sample preparation, enabling quick processing of the samples followed by an LC-MS method with a chromatographic run time of 9 minutes. The method was validated for selectivity, linearity, accuracy, imprecision, dilution integrity, recovery, process efficiency, ionization efficiency, and carryover effect. The method showed good selectivity without matrix interferences. For all analytes, the mean process efficiency was >86%, and the mean ionization efficiency was >94%. Furthermore, the accuracy was between 90.3% and 112% for all analytes, and the within- and between-run imprecision were <20% for the lower limit of quantification and <14.3% for the middle level and upper limit of quantification. The method presented here enables the simultaneous quantification of APAP and 6 of its metabolites. It is less time consuming than previously reported methods because it requires only a single and simple method for the sample preparation followed by an LC-MS method with a short run time. Therefore, this analytical method provides a useful method for both clinical and research purposes.
Slaughter, Andrew R; Palmer, Carolyn G; Muller, Wilhelmine J
2007-04-01
In aquatic ecotoxicology, acute to chronic ratios (ACRs) are often used to predict chronic responses from available acute data to derive water quality guidelines, despite many problems associated with this method. This paper explores the comparative protectiveness and accuracy of predicted guideline values derived from the ACR, linear regression analysis (LRA), and multifactor probit analysis (MPA) extrapolation methods applied to acute toxicity data for aquatic macroinvertebrates. Although the authors of the LRA and MPA methods advocate the use of extrapolated lethal effects in the 0.01% to 10% lethal concentration (LC0.01-LC10) range to predict safe chronic exposure levels to toxicants, the use of an extrapolated LC50 value divided by a safety factor of 5 was in addition explored here because of higher statistical confidence surrounding the LC50 value. The LRA LC50/5 method was found to compare most favorably with available experimental chronic toxicity data and was therefore most likely to be sufficiently protective, although further validation with the use of additional species is needed. Values derived by the ACR method were the least protective. It is suggested that there is an argument for the replacement of ACRs in developing water quality guidelines by the LRA LC50/5 method.
Andersen, Wendy C; Casey, Christine R; Schneider, Marilyn J; Turnipseed, Sherri B
2015-01-01
Prior to conducting a collaborative study of AOAC First Action 2012.25 LC-MS/MS analytical method for the determination of residues of three triphenylmethane dyes (malachite green, crystal violet, and brilliant green) and their metabolites (leucomalachite green and leucocrystal violet) in seafood, a single-laboratory validation of method 2012.25 was performed to expand the scope of the method to other seafood matrixes including salmon, catfish, tilapia, and shrimp. The validation included the analysis of fortified and incurred residues over multiple weeks to assess analyte stability in matrix at -80°C, a comparison of calibration methods over the range 0.25 to 4 μg/kg, study of matrix effects for analyte quantification, and qualitative identification of targeted analytes. Method accuracy ranged from 88 to 112% with 13% RSD or less for samples fortified at 0.5, 1.0, and 2.0 μg/kg. Analyte identification and determination limits were determined by procedures recommended both by the U. S. Food and Drug Administration and the European Commission. Method detection limits and decision limits ranged from 0.05 to 0.24 μg/kg and 0.08 to 0.54 μg/kg, respectively. AOAC First Action Method 2012.25 with an extracted matrix calibration curve and internal standard correction is suitable for the determination of triphenylmethane dyes and leuco metabolites in salmon, catfish, tilapia, and shrimp by LC-MS/MS at a residue determination level of 0.5 μg/kg or below.
Kakde, Rajendra B; Satone, Dinesh D; Gadapayale, Kamalesh K; Kakde, Megha G
2013-07-01
The objective of the current study was to develop a validated, specific stability-indicating reversed-phase liquid chromatographic (LC) method for the quantitative determination of escitalopram oxalate and clonazepam and their related substances in bulk drugs and pharmaceutical dosage forms in the presence of degradation products. Forced degradation studies were performed on the pure drugs of escitalopram oxalate and clonazepam, as per the stress conditions prescribed by the International Conference on Harmonization (ICH) using acid, base, oxidation, thermal stress and photolytic degradation to show the stability-indicating power of the method. Significant degradation was observed during acid and alkaline hydrolysis and no degradation was observed in other stress conditions. The chromatographic method was optimized using the samples generated from forced degradation studies. Good resolution between the peaks corresponded to the active pharmaceutical ingredients, escitalopram oxalate and clonazepam, and degradation products from the analyte were achieved on an ODS Hypersil C18 column (250 × 4.6 mm) using a mobile phase consisting of a mixture of acetonitrile-50 mM phosphate buffer + 10 mM triethylamine (70:30, v/v). The detection was conducted at 268 nm. The limit of detection and the limit of quantitation for escitalopram oxalate and clonazepam were established. The stress test solutions were assayed against the qualified working standards of escitalopram oxalate and clonazepam, which indicated that the developed LC method was stability-indicating. Validation of the developed LC method was conducted as per ICH requirements. The developed LC method was found to be suitable to check the quality of bulk samples of escitalopram oxalate and clonazepam.
LC-MSMS assays of urinary cortisol, a comparison between four in-house assays.
Brossaud, Julie; Leban, Monique; Corcuff, Jean-Benoit; Boux de Casson, Florence; Leloupp, Anne-Gaëlle; Masson, Damien; Moal, Valérie; Bach-Ngohou, Kalyane
2018-06-27
Twenty-four hour urinary free cortisol (UFC) determination can be used for screening and follow-up of Cushing syndrome (CS). As immunoassay methods lack specificity for UFC measurement, the use of high-performance liquid chromatography coupled to mass spectrometer (LC-MSMS) is recommended. The aim of our study was to compare UFC results using four LC-MSMS methods performed in four independent laboratories in order to evaluate interlaboratory agreement. Frozen aliquots of 24-h urine samples (78 healthy volunteers and 20 patients with CS) were sent to four different laboratories for analysis. Following liquid-liquid or solid-liquid extraction, UFC were determined using four different LC-MSMS assay. UFC intra- and interassays variation coefficients were lower than 10% for each centre. External quality control results were not significantly different. UFC normal ranges (established from healthy volunteers) were 17-126, 15-134, 12-118 and 27-157 nmol/day, respectively. Classification of UFC from healthy volunteers and patients with CS using a 95th percentile threshold was similar. However, for extreme UFC values (<50 or >270 nmol/day), negative or positive bias was noted. Even for highly specific methods such as LC-MSMS, variations of results can be found depending on analytical process. Validation of LC-MSMS methods including determination of the reference range is essential.
Crews, Colin
2015-01-01
The principles and application of established and newer methods for the quantitative and semi-quantitative determination of ergot alkaloids in food, feed, plant materials and animal tissues are reviewed. The techniques of sampling, extraction, clean-up, detection, quantification and validation are described. The major procedures for ergot alkaloid analysis comprise liquid chromatography with tandem mass spectrometry (LC-MS/MS) and liquid chromatography with fluorescence detection (LC-FLD). Other methods based on immunoassays are under development and variations of these and minor techniques are available for specific purposes. PMID:26046699
Pastor, Maria Delores; Nogal, Ana; Molina-Pinelo, Sonia; Quintanal-Villalonga, Álvaro; Meléndez, Ricardo; Ferrer, I; Romero-Romero, Beatrice; De Miguel, Maria José; López-Campos, José Luis; Corral, Jesús; García-Carboner, Rocío; Carnero, Amancio; Paz-Ares, Luis
2016-12-01
Lung cancer (LC) and chronic obstructive pulmonary disease (COPD) are smoking-related diseases, with the presence of COPD itself increasing the risk for development of LC, probably owing to underlying inflammation. LC is typically detected at late stages of the disease and carries a poor prognosis. There is an unmet need for methods to facilitate the early detection of LC in high-risk subjects such as smokers. The expression of inflammatory proteins in bronchoalveolar lavage fluid (BALF) samples was studied by antibody arrays in a prospective cohort of 60 smokers of more than 30 pack-years divided into four groups (control, patients with LC, patients with COPD, and patients with LC plus COPD). Relevant biomarkers were validated by Western blot. Additional validation with enzyme-linked immunosorbent assay (ELISA) was carried out on two independent controlled cohorts of 139 patients (control, patients with LC, patients with COPD, and patients with LC plus COPD) and 160 patients (control and patients with LC of all histological types). A total of 16 differentially expressed proteins in samples from patients with LC, COPD, and LC plus COPD were identified by antibody arrays and validated by Western blot and ELISA. C-C motif chemokine ligand 1 (CCL-1) and interleukin-11 (IL)-11 were selectively expressed in samples from patients with adenocarcinoma with or without COPD (p < 0.005). These proteins exhibited a remarkable diagnostic performance for lung adenocarcinoma in an independent cohort of 139 patients. Receiver operating characteristic curves showed that the optimum diagnostic cutoff value for IL-11 was 42 pg/mL (area under the curve = 0.93 [95% confidence interval: 0.896-0.975], sensitivity 90%, specificity 86%), whereas for CCL-1 it was 39.5 pg/mL (0.83 [95% confidence interval: 0.749-0.902], sensitivity 83%, and specificity 74%). Further validation of the ELISA biomarkers at the aforementioned cutoffs was performed in an additional cohort of 160 patients (20 controls, 66 patients with LC, and 74 patients with LC plus COPD). There was a significant correlation between BALF levels of IL-11 and CCL-1 (r 2 = 0.76, p < 0.001), and the use of both biomarkers increased the diagnostic accuracy to 96.1% in the two validation cohorts. Appropriate diagnostic performance was observed for all subgroups regardless of stage at diagnosis, involvement of the bronchial tract, pack-years smoked, and number of cells in BALF. IL-11 and CCL-1 are highly specific biomarkers with great accuracy for the diagnosis of lung adenocarcinoma in BALF specimens. Further study of these proteins as markers for the early diagnosis and screening of plasma and other biological materials is warranted. Copyright © 2016 International Association for the Study of Lung Cancer. Published by Elsevier Inc. All rights reserved.
Wang, Jin; Cao, Xianshuang; Jiang, Hao; Qi, Yadong; Chin, Kit L; Yue, Yongde
2014-12-17
Hibiscus sabdariffa has gained attention for its antioxidant activity. There are many accessions of H. sabdariffa in the world. However, information on the quantification of antioxidant compounds in different accessions is rather limited. In this paper, a liquid chromatography/quadrupole-time-of-flight mass spectrometry (LC-Q-TOF-MS) method for simultaneous determination of five antioxidant compounds (neochlorogenic acid, chlorogenic acid, cryptochlorogenic acid, rutin, and isoquercitrin) in H. sabdariffa leaves was developed. The method was validated for linearity, sensitivity, precision, repeatability and accuracy. The validated method has been successfully applied for determination of the five analytes in eight accessions of H. sabdariffa. The eight accessions of H. sabdariffa were evaluated for their antioxidant activities by DPPH free radical scavenging assay. The investigated accessions of H. sabdariffa were rich in rutin and exhibited strong antioxidant activity. The two accessions showing the highest antioxidant activities were from Cuba (No. 2) and Taiwan (No. 5). The results indicated that H. sabdariffa leaves could be considered as a potential antioxidant source for the food industry. The developed LC-Q-TOF-MS method is helpful for quality control of H. sabdariffa.
A simple, fast and sensitive screening LC-ESI-MS/MS method for antibiotics in fish.
Guidi, Letícia Rocha; Santos, Flávio Alves; Ribeiro, Ana Cláudia S R; Fernandes, Christian; Silva, Luiza H M; Gloria, Maria Beatriz A
2017-01-15
The objective of this study was to develop and validate a fast, sensitive and simple liquid chromatography-electrospray ionization-tandem mass spectrometry (LC-ESI-MS/MS) method for the screening of six classes of antibiotics (aminoglycosides, beta-lactams, macrolides, quinolones, sulfonamides and tetracyclines) in fish. Samples were extracted with trichloroacetic acid. LC separation was achieved on a Zorbax Eclipse XDB C18 column and gradient elution using 0.1% heptafluorobutyric acid in water and acetonitrile as mobile phase. Analysis was carried out in multiple reaction monitoring mode via electrospray interface operated in the positive ionization mode, with sulfaphenazole as internal standard. The method was suitable for routine screening purposes of 40 antibiotics, according to EC Guidelines for the Validation of Screening Methods for Residues of Veterinary Medicines, taking into consideration threshold value, cut-off factor, detection capability, limit of detection, sensitivity and specificity. Real fish samples (n=193) from aquaculture were analyzed and 15% were positive for enrofloxacin (quinolone), one of them at a higher concentration than the level of interest (50µgkg -1 ), suggesting possible contamination or illegal use of that antibiotic. Copyright © 2016 Elsevier B.V. All rights reserved.
Rower, Joseph E.; Bushman, Lane R.; Hammond, Kyle P.; Kadam, Rajendra S.; Aquilante, Christina L.
2011-01-01
Gemfibrozil, a fibric acid hypolipidemic agent, is increasingly being used in clinical drug-drug interaction studies as an inhibitor of drug metabolizing enzymes and drug transporters. The validation of a fast, accurate, and precise LC/MS method is described for the quantitative determination of gemfibrozil in an EDTA-anticoagulated human plasma matrix. Briefly, gemfibrozil was extracted from human plasma by an acetonitrile protein precipitation method. The assay was reproducible with intra-assay precision between 1.6% and 10.7%, and inter-assay precision ranging from 4.4% to 7.8%. The assay also showed good accuracy, with intra-assay concentrations within 85.6% and 108.7% of the expected value, and inter-assay concentrations within 89.4 to 104.0% of the expected value. The linear concentration range was between 0.5 and 50 μg/mL with a lower limit of quantitation of 0.5 μg/mL when 125 μL of plasma were extracted. This LC/MS method yielded a quick, simple, and reliable protocol for determining gemfibrozil concentrations in plasma and is applicable to clinical pharmacokinetic studies. PMID:21077249
Rower, Joseph E; Bushman, Lane R; Hammond, Kyle P; Kadam, Rajendra S; Aquilante, Christina L
2010-12-01
Gemfibrozil, a fibric acid hypolipidemic agent, is increasingly being used in clinical drug-drug interaction studies as an inhibitor of drug metabolizing enzymes and drug transporters. The validation of a fast, accurate and precise LC/MS method is described for the quantitative determination of gemfibrozil in an EDTA-anticoagulated human plasma matrix. Briefly, gemfibrozil was extracted from human plasma by an acetonitrile protein precipitation method. The assay was reproducible with intra-assay precision between 1.6 and 10.7%, and inter-assay precision ranging from 4.4 to 7.8%. The assay also showed good accuracy, with intra-assay concentrations within 85.6-108.7% of the expected value, and inter-assay concentrations within 89.4-104.0% of the expected value. The linear concentration range was between 0.5 and 50 µg/mL with a lower limit of quantitation of 0.5 µg/mL when 125 µL of plasma were extracted. This LC/MS method yielded a quick, simple and reliable protocol for determining gemfibrozil concentrations in plasma and is applicable to clinical pharmacokinetic studies. Copyright © 2010 John Wiley & Sons, Ltd.
Bateman, J; Proctor, M; Buchnev, O; Podoliak, N; D'Alessandro, G; Kaczmarek, M
2014-07-01
The voltage transfer function is a rapid and visually effective method to determine the electrical response of liquid crystal (LC) systems using optical measurements. This method relies on crosspolarized intensity measurements as a function of the frequency and amplitude of the voltage applied to the device. Coupled with a mathematical model of the device it can be used to determine the device time constants and electrical properties. We validate the method using photorefractive LC cells and determine the main time constants and the voltage dropped across the layers using a simple nonlinear filter model.
Hwang, Taeik; Noh, Eunyoung; Jeong, Ji Hye; Park, Sung-Kwan; Shin, Dongwoo; Kang, Hoil
2018-02-28
A sensitive and specific high-performance liquid chromatography-quadrupole time-of-flight-mass spectrometry (LC-QTOF-MS) method combined with liquid chromatography-tandem mass spectrometry (LC-MS/MS) was developed for the determination of grayanotoxins I and III in dietary supplements and homemade wine. Grayanotoxins I and III were successfully extracted using solid-phase extraction cartridges, characterized by LC-QTOF-MS, and quantitated by LC-MS/MS. The LC-MS/MS calibration curves were linear over concentrations of 10-100 ng/mL (grayanotoxin I) and 20-400 ng/mL (grayanotoxin III). Grayanotoxins I and III were found in 51 foodstuffs, with quantitative determinations revealing total toxin concentrations of 18.4-101 000 ng/mL (grayanotoxin I) and 15.3-56 000 ng/mL (grayanotoxin III). The potential of the validated method was demonstrated by successful quantitative analysis of grayanotoxins I and III in dietary supplements and homemade wine; the method appears suitable for the routine detection of grayanotoxins I and III from Rhododendron brachycarpum.
Chen, Lin; Xiao, Qingqing; Zhang, Xian; Yang, Jin
2016-03-20
2-[1-Hexyloxyethyl]-2-devinyl pyropheophorbide-a (HPPH) is a second-generation photosensitizer that has been applied in clinical studies of photodynamic therapy for a variety of malignant lesions. Based on the differences in selectivity and labour intensity, three novel methods - fluorescence detection coupled with high performance liquid chromatography (LC-FLD), LC-tandem mass spectrometry (LC-MS/MS) and fluorescence-based microplate reader methods - were developed for the determination of HPPH in human serum, which allowed comparison of fluorescence and MS platform for HPPH quantification. All three methods have been validated and successfully applied to support the clinical pharmacokinetic study of HPPH. The concentrations measured by LC-FLD matched those by LC-MS/MS with a correlation coefficient (r=0.994) and coefficient of determination (r(2)=0.989). Data consistency was also found between the measurements of microplate reader and LC-MS/MS with a correlation coefficient (r=0.999) and coefficient of determination (r(2)=0.998), indicating that fluorescence assay, the low cost alternative with a relatively poorer selectivity, is clearly suitable for the quantification of HPPH. Calibration curves in the methods of LC-FLD and microplate reader were linear (r˃0.998) over the concentration range from 50 to 5000 ng/mL, and linearity was obtained over the concentration range from 5 to 1000 ng/mL in the LC-MS/MS method. Compared with the other two methods, the fluorescence-based microplate reader method with proven high selectivity should be strongly recommended because of obvious advantages such as the lowest labour intensity, the lowest instrument cost, a better sensitivity than LC-FLD and the very rapid determination of large number of samples (24 samples/40 s). Copyright © 2015 Elsevier B.V. All rights reserved.
Xiong, Shan; Deng, Zhipeng; Sun, Peilu; Mu, Yanling; Xue, Mingxing
2017-11-01
Osimertinib is a new-generation epidermal growth factor inhibitor for the treatment of non-small cell lung cancer. In the present study, a rapid and sensitive LC with tandem MS method was developed and validated for the determination of osimertinib in rat plasma. Chromatographic separation was carried out on a C18 column using acetonitrile and water containing 0.1% formic acid. The assay was validated over a concentration range of 1.0-1000 ng/mL for osimertinib, with a lower LOQ of 1.0 ng/mL. The intra- and interday accuracy values for osimertinib ranged from 92.66 to 101.50% and from 97.08 to 99.15%, respectively, and the intra- and interday precision values for osimertinib ranged from 6.25 to 10.34% and from 3.43 to 10.44%, respectively. The method was successfully applied in a pharmacokinetic study of osimertinib after oral administration of osimertinib (4.5 mg/kg) to rats.
da Luz, Suzane Rickes; Pazdiora, Paulo Cesar; Dallagnol, Leandro José; Dors, Giniani Carla; Chaves, Fábio Clasen
2017-04-01
Wheat (Triticum aestivum) is an annual crop, cultivated in the winter and spring and susceptible to several pathogens, especially fungi, which are managed with fungicides. It is also one of the most consumed cereals, and can be contaminated by mycotoxins and fungicides. The objective of this study was to validate an analytical method by LC-MS for simultaneous determination of mycotoxins and fungicide residues in wheat grains susceptible to fusarium head blight treated with fungicides, and to evaluate the relationship between fungicide application and mycotoxin production. All parameters of the validated analytical method were within AOAC and ANVISA limits. Deoxynivalenol was the prevalent mycotoxin in wheat grain and epoxiconazole was the fungicide residue found in the highest concentration. All fungicidal treatments induced an increase in AFB2 production when compared to the control (without application). AFB1 and deoxynivalenol, on the contrary, were reduced in all fungicide treatments compared to the control. Copyright © 2016 Elsevier Ltd. All rights reserved.
Carter, Melissa D; Calcutt, M Wade; Malow, Beth A; Rose, Kristie L; Hachey, David L
2012-03-01
Melatonin (MEL) and its chemical precursor N-acetylserotonin (NAS) are believed to be potential biomarkers for sleep-related disorders. Measurement of these compounds, however, has proven to be difficult due to their low circulating levels, especially that of NAS. Few methods offer the sensitivity, specificity and dynamic range needed to monitor MEL and its precursors and metabolites in small blood samples, such as those obtained from pediatric patients. In support of our ongoing study to determine the safety, tolerability and PK dosing strategies for MEL in treating insomnia in children with autism spectrum disorder, two highly sensitive LC-MS/MS assays were developed for the quantitation of MEL and precursor NAS at pg/mL levels in small volumes of human plasma. A validated electrospray ionization (ESI) method was used to quantitate high levels of MEL in PK studies, and a validated nanospray (nESI) method was developed for quantitation of MEL and NAS at endogenous levels. In both assays, plasma samples were processed by centrifugal membrane dialysis after addition of stable isotopic internal standards, and the components were separated by either conventional LC using a Waters SymmetryShield RP18 column (2.1 × 100 mm, 3.5 µm) or on a polyimide-coated, fused-silica capillary self-packed with 17 cm AquaC18 (3 µm, 125 Å). Quantitation was done using the SRM transitions m/z 233 → 174 and m/z 219 → 160 for MEL and NAS, respectively. The analytical response ratio versus concentration curves were linear for MEL (nanoflow LC: 11.7-1165 pg/mL, LC: 1165-116,500 pg/mL) and for NAS (nanoflow LC: 11.0-1095 pg/mL). Copyright © 2012 John Wiley & Sons, Ltd.
Federal Register 2010, 2011, 2012, 2013, 2014
2012-09-28
...-nitroguanidine, in or on fruiting, vegetables, group 8-10, except pepper/eggplant subgroup 8-10B at 0.2 ppm; and pepper/eggplant subgroup 8-10B at 0.7 ppm. Adequate enforcement methodology (LC/MS/MS analysis) is... validated, including LC- MS/MS methods for use on tomato, pepper, melon, and cucumber. The analytical...
Born, Christoph; Amann, Benedikt L; Grunze, Heinz; Post, Robert M; Schärer, Lars
2014-05-07
Careful observation of the longitudinal course of bipolar disorders is pivotal to finding optimal treatments and improving outcome. A useful tool is the daily prospective Life-Chart Method, developed by the National Institute of Mental Health. However, it remains unclear whether the patient version is as valid as the clinician version. We compared the patient-rated version of the Lifechart (LC-self) with the Young-Mania-Rating Scale (YMRS), Inventory of Depressive Symptoms-Clinician version (IDS-C), and Clinical Global Impression-Bipolar version (CGI-BP) in 108 bipolar I and II patients who participated in the Naturalistic Follow-up Study (NFS) of the German centres of the Bipolar Collaborative Network (BCN; formerly Stanley Foundation Bipolar Network). For statistical evaluation, levels of severity of mood states on the Lifechart were transformed numerically and comparison with affective scales was performed using chi-square and t tests. For testing correlations Pearson´s coefficient was calculated. Ratings for depression of LC-self and total scores of IDS-C were found to be highly correlated (Pearson coefficient r = -.718; p < .001), whilst the correlation of ratings for mania with YMRS compared to LC-self were slightly less robust (Pearson coefficient r = .491; p = .001). These results were confirmed by good correlations between the CGI-BP IA (mania), IB (depression) and IC (overall mood state) and the LC-self ratings (Pearson coefficient r = .488, r = .721 and r = .65, respectively; all p < .001). The LC-self shows a significant correlation and good concordance with standard cross sectional affective rating scales, suggesting that the LC-self is a valid and time and money saving alternative to the clinician-rated version which should be incorporated in future clinical research in bipolar disorder. Generalizability of the results is limited by the selection of highly motivated patients in specialized bipolar centres and by the open design of the study.
USDA-ARS?s Scientific Manuscript database
The purpose of this study was to develop a Single-Lab Validated Method using high-performance liquid chromatography (HPLC) with different detectors (diode array detector - DAD, fluorescence detector - FLD, and mass spectrometer - MS) for determination of seven B-complex vitamins (B1 - thiamin, B2 – ...
Zhang, Donglu; Raghavan, Nirmala; Chando, Theodore; Gambardella, Janice; Fu, Yunlin; Zhang, Duxi; Unger, Steve E; Humphreys, W Griffith
2007-12-01
An LC-MS/MS-based approach that employs authentic radioactive metabolites as reference standards was developed to estimate metabolite exposures in early drug development studies. This method is useful to estimate metabolite levels in studies done with non-radiolabeled compounds where metabolite standards are not available to allow standard LC-MS/MS assay development. A metabolite mixture obtained from an in vivo source treated with a radiolabeled compound was partially purified, quantified, and spiked into human plasma to provide metabolite standard curves. Metabolites were analyzed by LC-MS/MS using the specific mass transitions and an internal standard. The metabolite concentrations determined by this approach were found to be comparable to those determined by valid LC-MS/MS assays. This approach does not requires synthesis of authentic metabolites or the knowledge of exact structures of metabolites, and therefore should provide a useful method to obtain early estimates of circulating metabolites in early clinical or toxicological studies.
Bureš, Jan; Jansová, Hana; Stariat, Ján; Filipský, Tomáš; Mladěnka, Přemysl; Šimůnek, Tomáš; Kučera, Radim; Klimeš, Jiří; Wang, Qin; Franz, Katherine J.; Kovaříková, Petra
2015-01-01
Salicylaldehyde isonicotinoyl hydrazone (SIH) is an intracellular iron chelator with well documented potential to protect against oxidative injury both in vitro and in vivo. However, it suffers from short biological half-life caused by fast hydrolysis of the hydrazone bond. Recently, a concept of boronate prochelators has been introduced as a strategy that might overcome these limitations. This study presents two complementary analytical methods for detecting the prochelator BSIH (boronyl salicylaldehyde isonicotinoyl hydrazone) along with its active metal-binding chelator SIH in different solution matrices and concentration ranges. An LC-UV method for determination of BSIH and SIH in buffer and cell culture medium was validated over concentrations of 7 – 115 and 4 – 115 μM, respectively, and applied to BSIH activation experiments in vitro. An LC-MS assay was validated for quantification of BSIH and SIH in plasma over the concentration range of 0.06 – 23 and 0.24 – 23 μM, respectively, and applied to stability studies in plasma in vitro as well as analysis of plasma taken after i.v. administration of BSIH to rats. A Zorbax-RP bonus column and mobile phases containing either phosphate buffer with EDTA or ammonium formate and methanol/acetonitrile mixture provided suitable conditions for the LC-UV and LC-MS analysis, respectively. Samples were diluted or precipitated with methanol prior to analysis. These separative analytical techniques establish the first validated protocols to investigate BSIH activation by hydrogen peroxide in multiple matrices, directly compare the stabilities of the prochelator and chelator in plasma, and provide the first basic pharmacokinetic data of this prochelator. Experiments reveal that BSIH is stable in all media tested and is partially converted to SIH by H2O2. The observed integrity of BSIH in plasma samples from the in vivo study suggest that the concept of prochelation might be a promising strategy for further development of aroylhydrazone cytoprotective agents. PMID:25527982
Hsu, Wei-Yi; Chen, Ching-Ming; Tsai, Fuu-Jen; Lai, Chien-Chen
2013-05-01
Urinary homovanillic acid (HVA)/vanillylmandelic acid (VMA), orotic acid (OA), and homogentisic acid (HGA) are diagnostic biomarkers of neuroblastoma, ornithine carbamoyl transferase deficiency (OCTD), and alkaptonuria (AKU), respectively. In this study, a high-performance liquid chromatography-tandem mass spectrometry (LC-MS/MS) method was developed for simultaneous quantification of HVA, VMA, OA, and HGA in urine. After sample preparation, which involved only the dilution procedure, samples were quantified by LC-MS/MS. Full-scan MS/MS mode enabled the urinary markers to be quantified with a high degree of specificity and sensitivity. Rather than using a separate enzymatic method to normalize the concentration of creatinine in urine, we quantified the level of creatinine in urine in one LC-MS run. The limits of detection were 10 μg/l for HGA, 25 μg/l for HVA/VMA, and 50 μg/l for OA with a single-to-noise ratio of 3; the limits of quantification were 50 μg/l for HVA and HGA, 100 μg/l for VMA, and 250 μg/l for OA. The linear dynamic range for quantification of the analytes covered 2 to 3 orders of magnitude, depending on the analyte. The relative standard deviation of the developed LC-MS/MS method was less than 4% for the intra-day validation and 10% for the inter-day validation. The results show that our LC-MS/MS technique is a highly sensitive and rapid method for screening for biomarkers that are diagnostic of three metabolic diseases. Copyright © 2012 Elsevier B.V. All rights reserved.
Identification of Forced Degradation Products of Itopride by LC-PDA and LC-MS.
Joshi, Payal; Bhoir, Suvarna; Bhagwat, A M; Vishwanath, K; Jadhav, R K
2011-05-01
Degradation products of itopride formed under different forced conditions have been identified using LC-PDA and LC-MS techniques. Itopride was subjected to forced degradation under the conditions of hydrolysis, photolysis, oxidation, dry and wet heat, in accordance with the International Conference on Harmonization. The stress solutions were chromatographed on reversed phase C18 (250×4.6 mm, 5 μm) column with a mobile phase methanol:water (55:45, v/v) at a detection wavelength of 215 nm. Itopride degraded in acid, alkali and oxidative stress conditions. The stability indicating method was developed and validated. The degradation pathway of the drug to products II-VIII is proposed.
Identification of Forced Degradation Products of Itopride by LC-PDA and LC-MS
Joshi, Payal; Bhoir, Suvarna; Bhagwat, A. M.; Vishwanath, K.; Jadhav, R. K.
2011-01-01
Degradation products of itopride formed under different forced conditions have been identified using LC-PDA and LC-MS techniques. Itopride was subjected to forced degradation under the conditions of hydrolysis, photolysis, oxidation, dry and wet heat, in accordance with the International Conference on Harmonization. The stress solutions were chromatographed on reversed phase C18 (250×4.6 mm, 5 μm) column with a mobile phase methanol:water (55:45, v/v) at a detection wavelength of 215 nm. Itopride degraded in acid, alkali and oxidative stress conditions. The stability indicating method was developed and validated. The degradation pathway of the drug to products II-VIII is proposed. PMID:22457552
Shin, Jeong-Sook; Peng, Lei; Kang, Kyungsu; Choi, Yongsoo
2016-09-09
Direct analysis of prostaglandin-E2 (PGE2) and -D2 (PGD2) produced from a RAW264.7 cell-based reaction was performed by liquid chromatography high-resolution mass spectrometry (LC-HRMS), which was online coupled with turbulent flow chromatography (TFC). The capability of this method to accurately measure PG levels in cell reaction medium containing cytokines or proteins as a reaction byproduct was cross-validated by two conventional methods. Two methods, including an LC-HRMS method after liquid-liquid extraction (LLE) of the sample and a commercial PGE2 enzyme-linked immunosorbent assay (ELISA), showed PGE2 and/or PGD2 levels almost similar to those obtained by TFC LC-HRMS over the reaction time after LPS stimulation. After the cross-validation, significant analytical throughputs, allowing simultaneous screening and potency evaluation of 80 natural products including 60 phytochemicals and 20 natural product extracts for the inhibition of the PGD2 produced in the cell-based inflammatory reaction, were achieved using the TFC LC-HRMS method developed. Among the 60 phytochemicals screened, licochalcone A and formononetin inhibited PGD2 production the most with IC50 values of 126 and 151nM, respectively. For a reference activity, indomethacin and diclofenac were used, measuring IC50 values of 0.64 and 0.21nM, respectively. This method also found a butanol extract of Akebia quinata Decne (AQ) stem as a promising natural product for PGD2 inhibition. Direct and accurate analysis of PGs in the inflammatory cell reaction using the TFC LC-HRMS method developed enables the high-throughput screening and potency evaluation of as many as 320 samples in less than 48h without changing a TFC column. Copyright © 2016 Elsevier B.V. All rights reserved.
Hessling, Bernd; Büttner, Knut; Hecker, Michael; Becher, Dörte
2013-01-01
Quantitative LC-MALDI is an underrepresented method, especially in large-scale experiments. The additional fractionation step that is needed for most MALDI-TOF-TOF instruments, the comparatively long analysis time, and the very limited number of established software tools for the data analysis render LC-MALDI a niche application for large quantitative analyses beside the widespread LC–electrospray ionization workflows. Here, we used LC-MALDI in a relative quantification analysis of Staphylococcus aureus for the first time on a proteome-wide scale. Samples were analyzed in parallel with an LTQ-Orbitrap, which allowed cross-validation with a well-established workflow. With nearly 850 proteins identified in the cytosolic fraction and quantitative data for more than 550 proteins obtained with the MASCOT Distiller software, we were able to prove that LC-MALDI is able to process highly complex samples. The good correlation of quantities determined via this method and the LTQ-Orbitrap workflow confirmed the high reliability of our LC-MALDI approach for global quantification analysis. Because the existing literature reports differences for MALDI and electrospray ionization preferences and the respective experimental work was limited by technical or methodological constraints, we systematically compared biochemical attributes of peptides identified with either instrument. This genome-wide, comprehensive study revealed biases toward certain peptide properties for both MALDI-TOF-TOF- and LTQ-Orbitrap-based approaches. These biases are based on almost 13,000 peptides and result in a general complementarity of the two approaches that should be exploited in future experiments. PMID:23788530
Cheng, Keding; Sloan, Angela; McCorrister, Stuart; Peterson, Lorea; Chui, Huixia; Drebot, Mike; Nadon, Celine; Knox, J David; Wang, Gehua
2014-12-01
The need for rapid and accurate H typing is evident during Escherichia coli outbreak situations. This study explores the transition of MS-H, a method originally developed for rapid H antigen typing of E. coli using LC-MS/MS of flagella digest of reference strains and some clinical strains, to E. coli isolates in clinical scenario through quantitative analysis and method validation. Motile and nonmotile strains were examined in batches to simulate clinical sample scenario. Various LC-MS/MS batch run procedures and MS-H typing rules were compared and summarized through quantitative analysis of MS-H data output for a standard method development. Label-free quantitative data analysis of MS-H typing was proven very useful for examining the quality of MS-H result and the effects of some sample carryovers from motile E. coli isolates. Based on this, a refined procedure and protein identification rule specific for clinical MS-H typing was established and validated. With LC-MS/MS batch run procedure and database search parameter unique for E. coli MS-H typing, the standard procedure maintained high accuracy and specificity in clinical situations, and its potential to be used in a clinical setting was clearly established. © 2014 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.
Gielecińska, Iwona; Mojska, Hanna
2013-01-01
Numerous studies have demonstrated acrylamide to be both neurotoxic and carcinogenic. At present it is widely recognised that acrylamide is mainly formed through the Maillard reaction from free asparagine and reducing sugars. The major sources of dietary acrylamide are potato products, processed cereals and coffee. To optimise and validate an analytical method for determining acrylamide in coffee by liquid chromatography and tandem mass spectrometry analysis (LC/MS/MS) using SPE clean-up. Analytical separation of acrylamide from roasted coffee was performed by liquid chromatography using a Hypercarb column followed by LC/MS/MS analysis, with 2,3,3-d3 acrylamide as an internal standard. The method was based on two purification steps: the first with hexane and Carrez solutions in order to remove of fat and to precipitate proteins, respectively; and the second with a solid-phase extraction (SPE) column which proved to be efficient in the elimination of the main chromatographic interferences. Limit of quantification (LOQ) for measuring acrylamide in coffee was 50 microg/kg. The described method demonstrates satisfactory precision (RSD = 2.5%), repeatability (RSD = 9.2%) and accuracy (mean recovery - 97.4%). Our results confirm that LC-MS/MS with SPE clean-up is selective and suitable for determination of acrylamide in coffee. Indeed, this method meets the criteria of EU Commission Recommendations (No. 2007/331/EC and No. 2010/307/EU), on the monitoring of acrylamide levels in food.
Kahsay, Getu; Song, Huiying; Eerdekens, Fran; Tie, Yaxin; Hendriks, Danny; Van Schepdael, Ann; Cabooter, Deirdre; Adams, Erwin
2015-01-01
Misoprostol is a synthetic prostaglandin E1 analogue which is mainly used for prevention and treatment of gastric ulcers, but also for abortion due to its labour inducing effect. Misoprostol exists as a mixture of diastereoisomers (1:1) and has several related impurities owing to its instability at higher temperatures and moisture. A simple and robust reversed phase liquid chromatographic (RPLC) method is described for the separation of the related substances and a normal phase (NP) LC method for the separation of misoprostol diastereoisomers. The RPLC method was performed using an Ascentis Express C18 (150 mm × 4.6 mm, 5 μm) column kept at 35 °C. The mobile phase was a gradient mixture of mobile phase A (ACN-H2O-MeOH, 28:69:3 v/v/v) and mobile phase B (ACN-H2O-MeOH, 47:50:3 v/v/v) eluted at a flow rate of 1.5 mL/min. UV detection was performed at 200 nm. The NPLC method was undertaken by using an XBridge bare silica (150 mm × 2.1 mm, 3.5 μm) column at 35 °C. The mobile phase contained 1-propanol-heptane-TFA (4:96:0.1%, v/v/v), pumped at a flow rate of 0.5 mL/min. UV detection was performed at 205 nm. This LC method can properly separate the two diastereoisomers (Rs > 2) within an analysis time of less than 20 min. Both methods were validated according to the ICH guidelines. Furthermore, these new LC methods have been successfully applied for purity control and diastereoisomers ratio determination of misoprostol bulk drug, tablets and dispersion. Copyright © 2015 Elsevier B.V. All rights reserved.
Jank, Louise; Martins, Magda Targa; Arsand, Juliana Bazzan; Hoff, Rodrigo Barcellos; Barreto, Fabiano; Pizzolato, Tânia Mara
2015-01-01
This study describes the development and validation procedures for scope extension of a method for the determination of β-lactam antibiotic residues (ampicillin, amoxicillin, penicillin G, penicillin V, oxacillin, cloxacillin, dicloxacillin, nafcillin, ceftiofur, cefquinome, cefoperazone, cephapirine, cefalexin and cephalonium) in bovine milk. Sample preparation was performed by liquid-liquid extraction (LLE) followed by two clean-up steps, including low temperature purification (LTP) and a solid phase dispersion clean-up. Extracts were analysed using a liquid chromatography-electrospray-tandem mass spectrometry system (LC-ESI-MS/MS). Chromatographic separation was performed in a C18 column, using methanol and water (both with 0.1% of formic acid) as mobile phase. Method validation was performed according to the criteria of Commission Decision 2002/657/EC. Main validation parameters such as linearity, limit of detection, decision limit (CCα), detection capability (CCβ), accuracy, and repeatability were determined and were shown to be adequate. The method was applied to real samples (more than 250) and two milk samples had levels above maximum residues limits (MRLs) for cloxacillin - CLX and cefapirin - CFAP.
Magotra, Asmita; Sharma, Anjna; Gupta, Ajai Prakash; Wazir, Priya; Sharma, Shweta; Singh, Parvinder Pal; Tikoo, Manoj Kumar; Vishwakarma, Ram A; Singh, Gurdarshan; Nandi, Utpal
2017-08-15
In the present study, a simple, sensitive, specific and rapid liquid chromatography (LC) tandem mass spectrometry (MS/MS) method was developed and validated according to the Food and Drug Administration (FDA) guidelines for estimation of IIIM-MCD-211 (a potent oral candidate with promising action against tuberculosis) in mice plasma using carbamazepine as internal standard (IS). Bioanalytical method consisted of one step protein precipitation for sample preparation followed by quantitation in LC-MS/MS using positive electrospray ionization technique (ESI) operating in multiple reaction monitoring (MRM) mode. Elution was achieved in gradient mode on High Resolution Chromolith RP-18e column with mobile phase comprised of acetonitrile and 0.1% (v/v) formic acid in water at the flow rate of 0.4mL/min. Precursor to product ion transitions (m/z 344.5/218.4 and m/z 237.3/194.2) were used to measure analyte and IS, respectively. All validation parameters were well within the limit of acceptance criteria. The method was successfully applied to assess the pharmacokinetics of the candidate in mice following oral (10mg/kg) and intravenous (IV; 2.5mg/kg) administration. It was also effectively used to quantitate metabolic stability of the compound in mouse liver microsomes (MLM) and human liver microsomes (HLM) followed by its in-vitro-in-vivo extrapolation. Copyright © 2017 Elsevier B.V. All rights reserved.
Kinyua, Juliet; Covaci, Adrian; Maho, Walid; McCall, Ann-Kathrin; Neels, Hugo; van Nuijs, Alexander L N
2015-09-01
Sewage-based epidemiology (SBE) employs the analysis of sewage to detect and quantify drug use within a community. While SBE has been applied repeatedly for the estimation of classical illicit drugs, only few studies investigated new psychoactive substances (NPS). These compounds mimic effects of illicit drugs by introducing slight modifications to chemical structures of controlled illicit drugs. We describe the optimization, validation, and application of an analytical method using liquid chromatography coupled to positive electrospray tandem mass spectrometry (LC-ESI-MS/MS) for the determination of seven NPS in sewage: methoxetamine (MXE), butylone, ethylone, methylone, methiopropamine (MPA), 4-methoxymethamphetamine (PMMA), and 4-methoxyamphetamine (PMA). Sample preparation was performed using solid-phase extraction (SPE) with Oasis MCX cartridges. The LC separation was done with a HILIC (150 x 3 mm, 5 µm) column which ensured good resolution of the analytes with a total run time of 19 min. The lower limit of quantification (LLOQ) was between 0.5 and 5 ng/L for all compounds. The method was validated by evaluating the following parameters: sensitivity, selectivity, linearity, accuracy, precision, recoveries and matrix effects. The method was applied on sewage samples collected from sewage treatment plants in Belgium and Switzerland in which all investigated compounds were detected, except MPA and PMA. Furthermore, a consistent presence of MXE has been observed in most of the sewage samples at levels higher than LLOQ. Copyright © 2015 John Wiley & Sons, Ltd.
Tan, Zhirong; Ouyang, Dongsheng; Chen, Yao; Zhou, Gan; Cao, Shan; Wang, Yicheng; Peng, Xiujuan; Zhou, Honghao
2010-08-01
A sensitive and specific liquid chromatography-electrospray ionization-mass spectrometry (LC-ESI-MS/MS) method has been developed and validated for the identification and quantification of clebopride in human plasma using itopride as an internal standard. The method involves a simple liquid-liquid extraction. The analytes were separated by isocratic gradient elution on a CAPCELL MG-III C(18) (5 microm, 150 mm x 2.1 mm i.d.) column and analyzed in multiple reaction monitoring (MRM) mode with positive electrospray ionization (ESI) interface using the respective [M+H](+) ions, m/z 373.9-->m/z184.0 for clebopride, m/z 359.9-->m/z71.5 for itopride. The method was validated over the concentration range of 69.530-4450.0 pg/ml for clebopride. Within- and between-batch precision (RSD%) was all within 6.83% and accuracy ranged from -8.16 to 1.88%. The LLOQ was 69.530 pg/ml. The extraction recovery was on an average 77% for clebopride. The validated method was used to study the pharmacokinetics profile of clebopride in human plasma after oral administration of clebopride. Copyright 2010. Published by Elsevier B.V.
Bernardy, Jeffry A.; Hubert, Terrance D.; Ogorek, Jacob M.; Schmidt, Larry J.
2013-01-01
An LC/MS method was developed and validated for the quantitative determination and confirmation of antimycin-A (ANT-A) in water from lakes or streams. Three different water sample volumes (25, 50, and 250 mL) were evaluated. ANT-A was stabilized in the field by immediately extracting it from water into anhydrous acetone using SPE. The stabilized concentrated samples were then transported to a laboratory and analyzed by LC/MS using negative electrospray ionization. The method was determined to have adequate accuracy (78 to 113% recovery), precision (0.77 to 7.5% RSD with samples ≥500 ng/L and 4.8 to 17% RSD with samples ≤100 ng/L), linearity, and robustness over an LOQ range from 8 to 51 600 ng/L.
Bernardy, Jeffry A; Hubert, Terrance D; Ogorek, Jacob M; Schmidt, Larry J
2013-01-01
An LC/MS method was developed and validated for the quantitative determination and confirmation of antimycin-A (ANT-A) in water from lakes or streams. Three different water sample volumes (25, 50, and 250 mL) were evaluated. ANT-A was stabilized in the field by immediately extracting it from water into anhydrous acetone using SPE. The stabilized concentrated samples were then transported to a laboratory and analyzed by LC/MS using negative electrospray ionization. The method was determined to have adequate accuracy (78 to 113% recovery), precision (0.77 to 7.5% RSD with samples > or = 500 ng/L and 4.8 to 17% RSD with samples < or = 100 ng/L), linearity, and robustness over an LOQ range from 8 to 51 600 ng/L.
An improved brine shrimp larvae lethality microwell test method.
Zhang, Yi; Mu, Jun; Han, Jinyuan; Gu, Xiaojie
2012-01-01
This article described an improved brine shrimp larvae lethality microwell test method. A simply designed connecting vessel with alternative photoperiod was used to culture and collect high yield of active Artemia parthenogenetica nauplii for brine shrimp larvae lethality microwell test. Using this method, pure A. parthenogenetica nauplii suspension was easily cultured and harvested with high density about 100-150 larvae per milliliter and the natural mortality was reduced to near zero by elimination of unnecessary artificial disturbance. And its sensitivity was validated by determination of LC(50)-24 h of different reference toxicants including five antitumor agents, two pesticides, three organic pollutants, and four heavy metals salts, most of which exhibited LC(50)-24 h between 0.07 and 58.43 mg/L except for bleomycin and mitomycin C with LC(50)-24 h over 300 mg/L.
Liu, Yazhong; Zhou, Fang; Sang, Hua; Ye, Hui; Chen, Qianying; Yao, Lan; Ni, Ping; Wang, Guangji; Zhang, Jingwei
2017-04-15
Lysine-MCC-DM1, MCC-DM1 and DM1 are potential catabolites of trastuzumab emtansine (T-DM1). A convenient liquid chromatography-tandem mass spectrometry (LC-MS/MS) method was developed and validated to detect these catabolites simultaneously in in vitro investigations for the first time. Protein precipitation was utilized to prepare the samples. Chromatographic separation was achieved on a Phenomenex Kinetex C18 column (100×2.1mm, 2.6μm) with mobile-phase gradient elution. The calibration curves of each analyte ranging from 1 to 100nM showed good linearity (r 2 >0.995). The method was validated successfully and applied to the intracellular catabolism and regulation of T-DM1. Copyright © 2017 Elsevier B.V. All rights reserved.
Determination of lipophilic toxins by LC/MS/MS: single-laboratory validation.
Villar-González, Adriano; Rodríguez-Velasco, María Luisa; Gago-Martínez, Ana
2011-01-01
An LC/MS/MS method has been developed, assessed, and intralaboratory-validated for the analysis of the lipophilic toxins currently regulated by European Union legislation: okadaic acid (OA) and dinophysistoxins 1 and 2, including their ester forms; azaspiracids 1, 2, and 3; pectenotoxins 1 and 2; yessotoxin (YTX), and the analogs 45 OH-YTX, Homo YTX, and 45 OH-Homo YTX; as well as for the analysis of 13-desmetil-spirolide C. The method consists of duplicate sample extraction with methanol and direct analysis of the crude extract without further cleanup or concentration. Ester forms of OA and dinophysistoxins are detected as the parent ions after alkaline hydrolysis of the extract. The validation process of this method was performed using both fortified and naturally contaminated samples, and experiments were designed according to International Organization for Standardization, International Union of Pure and Applied Chemistry, and AOAC guidelines. With the exception of YTX in fortified samples, RSDr below 15% and RSDR were below 25%. Recovery values were between 77 and 95%, and LOQs were below 60 microg/kg. These data together with validation experiments for recovery, selectivity, robustness, traceability, and linearity, as well as uncertainty calculations, are presented in this paper.
Analysis of catecholamines in urine by unique LC/MS suitable ion-pairing chromatography.
Bergmann, Marianne L; Sadjadi, Seyed; Schmedes, Anne
2017-07-01
The catecholamines, epinephrine (E) and norepinephrine (NE) are small polar, hydrophilic molecules, posing significant challenges to liquid chromatography - tandem mass spectrometry (LC-MS/MS) method development. Specifically, these compounds show little retention on conventional reversed-phase liquid chromatography columns. This work presents development and validation of an LC-MS/MS method for determining catecholamines in urine, based on a new approach to ion-pairing chromatography (IPC), in which the ion-pairing reagent (IPR), 1-Heptane Sulfonic Acid (HSA), is added to the extracted samples instead of the mobile phases. A Hamilton STARlet workstation carried out the solid phase extraction of urine samples. The extracted samples were diluted with 60mmol/L HSA and injected on a Kinetex core-shell biphenyl column with conventional LC-MS/MS suitable mobile phases. Chromatographic separation of E and NE was achieved successfully with very stable retention times (RT). In 484 injections, the RTs were steady with a CV of less than ±4%. Furthermore, HSA was separated from E and NE, allowing HSA to be diverted to waste instead of entering the mass spectrometer ion chamber. The method was validated with good analytical performance, and even though the analysis for urinary catecholamines is increasingly being replaced by plasma free metanephrines in diagnosing pheochromocytomas, this work represents the application of a new analytical technique that can be transferred to other small polar molecules, that are difficult to chromatograph on traditional reversed phase columns. Copyright © 2017 Elsevier B.V. All rights reserved.
Geng, Chunmei; Li, Pingli; Chen, Xuwang; Yuan, Guiyan; Guo, Nan; Liu, Huanjun; Zhang, Rui; Guo, Ruichen
2017-05-23
To determine the feasibility of using a nanoparticle immunoassay for clinical therapeutic drug monitoring (TDM) of docetaxel concentrations, a sensitive and simple method of liquid chromatography-tandem mass spectrometry (LC-MS/MS) was established to measure the docetaxel concentration in human plasma and the results of LC-MS/MS and the immunoassay were compared. Docetaxel and paclitaxel (the internal standard, or IS) in human plasma were extracted through protein precipitation, separated on a Diamonsil C18 column (150 mm × 4.6 mm, 5 μm), ionized with positive ions, and detected with LC-MS/MS in multi-reaction monitoring (MRM) mode. Plasma samples from 248 cancer patients were assayed with LC-MS/MS and a nanoparticle immunoassay. Data from the samples were analyzed with the statistical software SPSS and the software MedCalc. Results indicated that the calibration curve of the validated method of LC-MS/MS was linear over the range of 10-2,000 ng/mL, with an lowest limit of quantitation (LLOQ) of 10 ng/mL, and the intra- and inter- day precision and accuracy were both < ± 15%. Comparison of the two methods indicated that results of the LC-MS/MS were closely related to those of the nanoparticle immunoassay, with a correlation coefficient (R) of 0.965 and acceptable 95% confidence intervals (CI) of ‒ 231.7-331.1 ng/mL. Overall, the established method of LC-MC/MS and the nanoparticle immunoassay were both suitable for measurement of the docetaxel concentration in human plasma, and the immunoassay was far more cost-effective and better at clinical TDM of docetaxel in clinical practice.
Robandt, P V; Bui, H M; Scancella, J M; Klette, K L
2010-10-01
An automated solid-phase extraction-liquid chromatography- tandem mass spectrometry (SPE-LC-MS-MS) method using the Spark Holland Symbiosis Pharma SPE-LC coupled to a Waters Quattro Micro MS-MS was developed for the analysis of 6-acetylmorphine (6-AM) in human urine specimens. The method was linear (R² = 0.9983) to 100 ng/mL, with no carryover at 200 ng/mL. Limits of quantification and detection were found to be 2 ng/mL. Interrun precision calculated as percent coefficient of variation (%CV) and evaluated by analyzing five specimens at 10 ng/mL over nine batches (n = 45) was 3.6%. Intrarun precision evaluated from 0 to 100 ng/mL ranged from 1.0 to 4.4%CV. Other opioids (codeine, morphine, oxycodone, oxymorphone, hydromorphone, hydrocodone, and norcodeine) did not interfere in the detection, quantification, or chromatography of 6-AM or the deuterated internal standard. The quantified values for 41 authentic human urine specimens previously found to contain 6-AM by a validated gas chromatography (GC)-MS method were compared to those obtained by the SPE-LC-MS-MS method. The SPE-LC-MS-MS procedure eliminates the human factors of specimen handling, extraction, and derivatization, thereby reducing labor costs and rework resulting from human error or technique issues. The time required for extraction and analysis was reduced by approximately 50% when compared to a validated 6-AM procedure using manual SPE and GC-MS analysis.
Reichert, Bárbara; de Kok, André; Pizzutti, Ionara Regina; Scholten, Jos; Cardoso, Carmem Dickow; Spanjer, Martien
2018-04-03
This paper describes the optimization and validation of an acetonitrile based method for simultaneous extraction of multiple pesticides and mycotoxins from raw coffee beans followed by LC-ESI-MS/MS determination. Before extraction, the raw coffee samples were milled and then slurried with water. The slurried samples were spiked with two separate standard solutions, one containing 131 pesticides and a second with 35 mycotoxins, which were divided into 3 groups of different relative concentration levels. Optimization of the QuEChERS approach included performance tests with acetonitrile acidified with acetic acid or formic acid, with or without buffer and with or without clean-up of the extracts before LC-ESI-MS/MS analysis. For the clean-up step, seven d-SPE sorbents and their various mixtures were evaluated. After method optimization a complete validation study was carried out to ensure adequate performance of the extraction and chromatographic methods. The samples were spiked at 3 concentrations levels with both mycotoxins and pesticides (with 6 replicates at each level, n = 6) and then submitted to the extraction procedure. Before LC-ESI-MS/MS analysis, the acetonitrile extracts were diluted 2-fold with methanol, in order to improve the chromatographic performance of the early-eluting polar analytes. Calibration standard solutions were prepared in organic solvent and in blank coffee extract at 7 concentration levels and analyzed 6 times each. The method was assessed for accuracy (recovery %), precision (RSD%), selectivity, linearity (r 2 ), limit of quantification (LOQ) and matrix effects (%). Copyright © 2017 Elsevier B.V. All rights reserved.
Trujillo, William A.; Sorenson, Wendy R.; La Luzerne, Paul; Austad, John W.; Sullivan, Darryl
2008-01-01
The presence of aristolochic acid in some dietary supplements is a concern to regulators and consumers. A method has been developed, by initially using a reference method as a guide, during single laboratory validation (SLV) for the determination of aristolochic acid I, also known as aristolochic acid A, in botanical species and dietary supplements at concentrations of approximately 2 to 32 μg/g. Higher levels were determined by dilution to fit the standard curve. Through the SLV, the method was optimized for quantification by liquid Chromatography with ultraviolet detection (LC-UV) and LC/mass Spectrometry (MS) confirmation. The test samples were extracted with organic solvent and water, then injected on a reverse phase LC column. Quantification was achieved with linear regression using a laboratory automation system. The SLV study included systematically optimizing the LC-UV method with regard to test sample size, fine grinding of solids, and solvent extraction efficiency. These parameters were varied in increments (and in separate optimization studies), in order to ensure that each parameter was individually studied; the test results include corresponding tables of parameter variations. In addition, the chromatographic conditions were optimized with respect to injection volume and detection wavelength. Precision studies produced overall relative standard deviation values from 2.44 up to 8.26% for aristolochic acid I. Mean recoveries were between 100 and 103% at the 2 μg/g level, between 102 and 103% at the 10 μg/g level, and 104% at the 30 μg/g level. PMID:16915829
Trujillo, William A; Sorenson, Wendy R; La Luzerne, Paul; Austad, John W; Sullivan, Darryl
2006-01-01
The presence of aristolochic acid in some dietary supplements is a concern to regulators and consumers. A method has been developed, by initially using a reference method as a guide, during single laboratory validation (SLV) for the determination of aristolochic acid I, also known as aristolochic acid A, in botanical species and dietary supplements at concentrations of approximately 2 to 32 microg/g. Higher levels were determined by dilution to fit the standard curve. Through the SLV, the method was optimized for quantification by liquid chromatography with ultraviolet detection (LC-UV) and LC/mass spectrometry (MS) confirmation. The test samples were extracted with organic solvent and water, then injected on a reverse phase LC column. Quantification was achieved with linear regression using a laboratory automation system. The SLV study included systematically optimizing the LC-UV method with regard to test sample size, fine grinding of solids, and solvent extraction efficiency. These parameters were varied in increments (and in separate optimization studies), in order to ensure that each parameter was individually studied; the test results include corresponding tables of parameter variations. In addition, the chromatographic conditions were optimized with respect to injection volume and detection wavelength. Precision studies produced overall relative standard deviation values from 2.44 up to 8.26% for aristolochic acid I. Mean recoveries were between 100 and 103% at the 2 microg/g level, between 102 and 103% at the 10 microg/g level, and 104% at the 30 microg/g level.
Li, Wenkui; Doherty, John P; Kulmatycki, Kenneth; Smith, Harold T; Tse, Francis Ls
2012-06-01
In support of a pilot clinical trial using acetaminophen as the model compound to assess dried blood spot (DBS) sampling as the method for clinical pharmacokinetic sample collection, a novel sensitive LC-MS/MS method was developed and validated for the simultaneous determination of acetaminophen and its major metabolites, acetaminophen glucuronide and sulfate, in human DBS samples collected by subjects via fingerprick. The validated assay dynamic range was from 50.0 to 5000 ng/ml for each compound using a 1/8´´ (3-mm) disc punched from a DBS sample. Baseline separation of the three analytes was achieved to eliminate the possible impact of insource fragmentation of the conjugated metabolites on the analysis of the parent. The overall extraction efficiency was from 61.3 to 78.8% for the three analytes by direct extraction using methanol. The validated method was successfully implemented in the pilot clinical study with the obtained pharmacokinetic parameters in agreement with the values reported in literature.
Gao, Xinliu; Lin, Hui; Krantz, Carsten; Garnier, Arlette; Flarakos, Jimmy; Tse, Francis L S; Li, Wenkui
2016-01-01
Factor P (Properdin), an endogenous glycoprotein, plays a key role in innate immune defense. Its quantification is important for understanding the pharmacodynamics (PD) of drug candidate(s). In the present work, an immunoaffinity capturing LC-MS/MS method has been developed and validated for the first time for the quantification of factor P in monkey serum with a dynamic range of 125 to 25,000 ng/ml using the calibration standards and QCs prepared in factor P depleted monkey serum. The intra- and inter-run precision was ≤7.2% (CV) and accuracy within ±16.8% (%Bias) across all QC levels evaluated. Results of other evaluations (e.g., stability) all met the acceptance criteria. The validated method was robust and implemented in support of a preclinical PK/PD study.
Goldschmidt, Robert J; Wolf, Wayne R
2010-05-01
Assessing dietary intake of vitamins from all sources, including foods, dietary supplements, and fortified foods, would be aided considerably by having analytical methodologies that are capable of simultaneous determination of several vitamins. Vitamins naturally present in foods may occur in different chemical forms, with levels ranging over several orders of magnitude. Vitamins in dietary supplements and fortified foods, however, are typically added in a single chemical form, and matrix issues are usually not as complex. These sources should thus be relatively amenable to approaches that aim for simultaneous determination of multiple vitamins. Our recent work has focused on development of liquid chromatography (LC)-UV/fluorescence and LC-tandem mass spectrometry methods for the simultaneous determination of water-soluble vitamins (thiamine, niacin, pyridoxine, pantothenic acid, folic acid, biotin, and riboflavin) in dietary supplement tablets and fortified foods, such as formula powders and breakfast cereals. As part of the validation of our methods and collaboration in characterization of a new NIST SRM 1849 Infant/Adult Nutritional Formula powder, we report data on SRM 1849 using isotope dilution mass spectrometric methods. Use of available NIST Standard Reference Materials(R) as test matrices in our method development and validation gives a benchmark for future application of these methods. We compare three chromatographic approaches and provide data on stability of vitamin standard solutions for LC-based multiple vitamin determinations.
Tang, Wai-Tong; Wong, Sui-Kay; Law, Tin-Yau; Pang, Kwok-Chu; Sin, Della; Tam, Yin-King
2008-01-01
A study of single-laboratory validation (SLV) of a reversed-phase liquid Chromatography (RP-LC) method was conducted for the determination of diester-diterpene Aconitum alkaloids, viz., aconitine, mesaconitine, and hypaconitine, in a variety of dietary supplements, including single-arid multiple-ingredient dry powder extracts, pills, capsules, and raw materials. The Aconitum alkaloids in the samples were extracted by diethyl ether in the presence of ammonia. After cleanup with solid-phase extraction to remove the matrix interferences, the alkaloids were determined by RP-LC with UV detection at 235 nm, and the results were confirmed by tandem mass Spectrometry. The linear responses for aconitine, mesaconitine, and hypaconitine based on the present LC system ranged from 0.5 to 200 μg/mL. Relative standard deviations of 2.0 to 6.9% were obtained from duplicate analysis of 6 test materials of different matrixes for the 3 Aconitum alkaloids performed by 2 analysts on 5 different days. The recoveries determined for supplements and raw materials spiked with 3 Aconitum alkaloids at levels of 2.5–10 μg/g were in the range of 86–99%. In view of the attainment of satisfactory results for accuracy, precision, and recovery in the SLV study, it is recommended that the method validation process proceed to a collaborative study. PMID:17225594
Peaston, Robert T; Graham, Kendon S; Chambers, Erin; van der Molen, Jan C; Ball, Stephen
2010-04-02
Plasma free metanephrines have proved a highly sensitive biochemical test for the diagnosis of pheochromocytoma. We have developed and validated a simple, LC-MS/MS method to determine plasma metanephrines and compared the diagnostic efficacy of the method with an enzyme immunoassay procedure in 151 patients, 38 with histologically confirmed pheochromocytoma. Off-line solid phase extraction in a 96-well plate format was used to isolate metanephrines from 100-microL of plasma, followed by rapid separation with hydrophilic interaction chromatography. Mass spectrometry detection was performed in multiple-reaction monitoring mode using a tandem quadrupole mass spectrometer with positive electrospray ionization. Detection limits were <0.1nmol/l with method linearity up to 23.0nmol/L for normetanephrine (NMN), metanephrine (MN) and 3-methoxytyramine (3-MT). Method comparison with an automated LC-MS/MS yielded Deming regression slopes of r=0.94 for NMN, r=0.98 for MN and r=0.94 for 3-MT. Method comparison with enzyme immunoassay revealed regression slope of r=1.28 (NMN) and 1.25 (MN) with values approximately 25% lower than LC-MS/MS. Plasma metanephrines by LC-MS/MS identified all 38 patients with phaeochromocytoma compared with 36 cases by immunoassay. Plasma metanephrines measured by LC-MS/MS are a reliable and sensitive test for the biochemical detection of pheochromocytoma. 2010 Elsevier B.V. All rights reserved.
Holland, Patrick T; McNabb, Paul; Selwood, Andrew I; Neil, Tracey
2003-01-01
A liquid chromatography/mass spectrometry (LC/MS) method for amnesic shellfish poisoning toxins in shellfish was developed and validated. Tissue homogenate (4 g) was extracted with 16 mL methanol-water (1 + 1, v/v). Dilution into acetonitrile-water (1 + 9, v/v) was followed by C18 solid-phase extraction cleanup. Domoic acid (DA) and epi-domoic acid were determined by LC/MS/MS with electrospray ionization and multiple reaction monitoring. External calibration was performed with dilutions of a certified reference standard. Advantages of this method include speed, lower detection limits, and a very high degree of specificity. The LC/MS response was highly linear, and there were no significant interferences to the determination of DA. Formal method validation was performed on 4 shellfish species. Fortification studies gave recoveries (mean +/- SD; n = 24) of 93 +/- 14% at 1 mg/kg, and 93.3 +/- 7.6% at 20 mg/kg over all the species. Analysis of a mussel certified reference material showed the bias as < 5%. The limits of detection and quantitation were 0.15 and 0.5 mg/kg, respectively. Routine application of the method over 4 months gave a recovery for the QC sample (1 mg/kg fortified blank mussel homogenate) run with each batch of 88.9 +/- 5.5% (mean +/- SD; n = 37). The total uncertainty of measurement results were estimated as 0.12 (12%) at 0.25-5 mg/kg and 0.079 (7.9%) at 5-50 mg/kg. The major contribution to the uncertainty was the repeatability of the LC/MS determination, probably arising from subtle matrix effects.
Analysis of benzodiazepines and their metabolites using DBS cards and LC-MS/MS.
Lee, Heesang; Park, Yujin; Jo, Jiyeong; In, Sangwhan; Park, Yonghoon; Kim, Eunmi; Pyo, Jaesung; Choe, Sanggil
2015-10-01
Dried Blood Spot (DBS) has been used a blood extraction method for inherited metabolic disorder screening since 1960s. With introduction of LC-MS/MS, not only DBS could be used to analysis drugs in small blood volume, but in various fields, such as toxicology, drug therapeutic monitoring, drug diagnostic screening, and illicit drugs. In toxicology field, many drugs (e.g. benzodiazepines, acetaminophen, small molecule drugs) have been tested with DBS. Compared with earlier blood extraction methods (SPE and LLE), DBS has lots of advantages; lower blood volume (less than 50μL), shorter analysis time caused by a more concise analysis procedure and lower cost. We optimized the DBS procedure and LC-MS/MS conditions for 18 benzodiazepines, seven benzodiazepine metabolites, and one z-drug (zolpidem) analysis in blood. 30μL of whole blood was spotted on FTA DMPK card C and dried for 2h in a desiccator. A 6-mm disk was punched and vortexed for 1min in a centrifuge tube with 300μL methanol/acetonitrile mixture (1:1, v/v). After evaporation, redissolved in 100μL mobile phase of LC-MS/MS and 5μL was injected. In the analysis for 26 target compounds in blood, all of the method validation parameters - LLOD, LLOQ, accuracy (intra- and inter-assay), and precision (intra- and inter-assay) - were satisfied with method validation criteria, within 15%. The results of matrix effect, recovery, and process efficiency were good. We developed a fast and reliable sample preparation method using DBS for 26 benzodiazepines, benzodiazepine metabolites, and z-drug (zolpidem). Copyright © 2015 Elsevier Ireland Ltd. All rights reserved.
Jiang, Hongliang; Wang, Yurong; Shet, Manjunath S; Zhang, Yang; Zenke, Duane; Fast, Douglas M
2011-09-01
A rapid, specific, and reliable LC-MS/MS based bioanalytical method was developed and validated for the simultaneous determination of naloxone (NLX) and its two metabolites, 6β-naloxol (NLL) and naloxone-3β-D-glucuronide (NLG) in mouse plasma. The optimal chromatographic behavior of these analytes was achieved on an Aquasil C18 column (50 mm × 2.1 mm, 5 μm) using reversed phase chromatography. The total LC analysis time per injection was 2.5 min with a flow rate of 1.0 mL/min with gradient elution. Sample preparation via protein precipitation with acetonitrile in a 96-well format was applied for analyses of these analytes. The analytes were monitored by electrospray ionization in positive ion multiple reaction monitoring (MRM) mode. Modification of collision energy besides chromatographic separation was applied to further eliminate interference peaks for NLL and NLG. The method validation was conducted over the curve range of 0.200/0.400/0.500 to 100/200/250 ng/mL for NLX/NLL/NLG, respectively, using 0.0250 mL of plasma sample. The intra- and inter-day precision and accuracy of the quality control samples at low, medium, and high concentration levels showed ≤ 6.5% relative standard deviation (RSD) and -8.3 to -2.5% relative error (RE). The method was successfully applied to determine the concentrations of NLX, NLL, and NLG in incurred mouse plasma samples. Copyright © 2011 Elsevier B.V. All rights reserved.
Bathena, Sai P; Huang, Jiangeng; Epstein, Adrian A; Gendelman, Howard E; Boska, Michael D; Alnouti, Yazen
2012-04-15
Amino acids and myo-inositol have long been proposed as putative biomarkers for neurodegenerative diseases. Accurate measures and stability have precluded their selective use. To this end, a sensitive liquid chromatography tandem mass spectrometry (LC-MS/MS) method based on multiple reaction monitoring was developed to simultaneously quantify glutamine, glutamate, γ-aminobutyric acid (GABA), aspartic acid, N-acetyl aspartic acid, taurine, choline, creatine, phosphocholine and myo-inositol in mouse brain by methanol extractions. Chromatography was performed using a hydrophilic interaction chromatography silica column within in a total run time of 15 min. The validated method is selective, sensitive, accurate, and precise. The method has a limit of quantification ranging from 2.5 to 20 ng/ml for a range of analytes and a dynamic range from 2.5-20 to 500-4000 ng/ml. This LC-MS/MS method was validated for biomarker discovery in models of human neurological disorders. Copyright © 2012 Elsevier B.V. All rights reserved.
EL-Houssini, Ola M.; Zawilla, Nagwan H.; Mohammad, Mohammad A.
2013-01-01
Specific stability indicating reverse-phase liquid chromatography (RP-LC) assay method (SIAM) was developed for the determination of cinnarizine (Cinn)/piracetam (Pira) and cinnarizine (Cinn)/heptaminol acefyllinate (Hept) in the presence of the reported degradation products of Cinn. A C18 column and gradient mobile phase was applied for good resolution of all peaks. The detection was achieved at 210 nm and 254 nm for Cinn/Pira and Cinn/Hept, respectively. The responses were linear over concentration ranges of 20–200, 20–1000 and 25–1000 μgmL−1 for Cinn, Pira, and Hept respectively. The proposed method was validated for linearity, accuracy, repeatability, intermediate precision, and robustness via statistical analysis of the data. The method was shown to be precise, accurate, reproducible, sensitive, and selective for the analysis of Cinn/Pira and Cinn/Hept in laboratory prepared mixtures and in pharmaceutical formulations. PMID:24137049
Kumar, Thangarathinam; Ramya, Mohandass; Srinivasan, Viswanathan; Xavier, N
2017-08-01
Hydroxylamine is a known genotoxic impurity compound that needs to be controlled down to ppm level in pharmaceutical processes. It is difficult to detect using conventional analytical techniques due to its physio-chemical properties like lack of chromophore, low molecular weight, absence of carbon atom and high polarity. In addition to that, analysis of the pharmaceutical samples encounters considerable obstruction from matrix components that greatly overshadow the response of hydroxylamine. This study describes a simple, sensitive and direct Liquid Chromatographic-Mass Spectrometric method (LC-MS) for detection of hydroxylamine in pharmaceutical compounds. The LC-MS method was detected up to 0.008 ppm of hydroxylamine with S/N > 3.0 and quantified up to 0.025 ppm of hydroxylamine with S/N ratio >10.0. This validated method can be applied as a generic method to detect the hydroxylamine for pharmaceutical process control and drug substance release. © The Author 2017. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.
Automated solid-phase extraction workstations combined with quantitative bioanalytical LC/MS.
Huang, N H; Kagel, J R; Rossi, D T
1999-03-01
An automated solid-phase extraction workstation was used to develop, characterize and validate an LC/MS/MS method for quantifying a novel lipid-regulating drug in dog plasma. Method development was facilitated by workstation functions that allowed wash solvents of varying organic composition to be mixed and tested automatically. Precision estimates for this approach were within 9.8% relative standard deviation (RSD) across the calibration range. Accuracy for replicate determinations of quality controls was between -7.2 and +6.2% relative error (RE) over 5-1,000 ng/ml(-1). Recoveries were evaluated for a wide variety of wash solvents, elution solvents and sorbents. Optimized recoveries were generally > 95%. A sample throughput benchmark for the method was approximately equal 8 min per sample. Because of parallel sample processing, 100 samples were extracted in less than 120 min. The approach has proven useful for use with LC/MS/MS, using a multiple reaction monitoring (MRM) approach.
Ichibangase, Tomoko; Sugawara, Yasuhiro; Yamabe, Akio; Koshiyama, Akiyo; Yoshimura, Akari; Enomoto, Takemi; Imai, Kazuhiro
2012-01-01
Systems biology aims to understand biological phenomena in terms of complex biological and molecular interactions, and thus proteomics plays an important role in elucidating protein networks. However, many proteomic methods have suffered from their high variability, resulting in only showing altered protein names. Here, we propose a strategy for elucidating cellular protein networks based on an FD-LC-MS/MS proteomic method. The strategy permits reproducible relative quantitation of differences in protein levels between different cell populations and allows for integration of the data with those obtained through other methods. We demonstrate the validity of the approach through a comparison of differential protein expression in normal and conditional superoxide dismutase 1 gene knockout cells and believe that beginning with an FD-LC-MS/MS proteomic approach will enable researchers to elucidate protein networks more easily and comprehensively. PMID:23029042
Barrett, Yu Chen; Akinsanya, Billy; Chang, Shu-Ying; Vesterqvist, Ole
2005-07-25
A sensitive method for quantitation of urinary 6beta-hydroxycortisol (6beta-HC) and cortisol using on-line SPE and LC-MS/MS was developed and validated. Human urine samples were injected directly onto an on-line solid phase extraction apparatus, Prospekt-2, followed by HPLC separation and electrospray triple quadrupole LC-MS/MS detection. The inter-day precision for the 6beta-HC:cortisol ratio was 7-9%. The lower limit of quantitation was 1 and 0.2 ng/mL for 6beta-HC and cortisol, respectively. Using the method we observed a diurnal variation on the 6beta-HC:cortisol ratio in healthy volunteers with the maximal ratio observed in the 2-10 pm urine collection period.
Molins, C; Hogendoorn, E A; Dijkman, E; Heusinkveld, H A; Baumann, R A
2000-02-11
The combination of microwave-assisted solvent extraction (MASE) and reversed-phase liquid chromatography (RPLC) with UV detection has been investigated for the efficient determination of phenylurea herbicides in soils involving the single-residue method (SRM) approach (linuron) and the multi-residue method (MRM) approach (monuron, monolinuron, isoproturon, metobromuron, diuron and linuron). Critical parameters of MASE, viz, extraction temperature, water content and extraction solvent were varied in order to optimise recoveries of the analytes while simultaneously minimising co-extraction of soil interferences. The optimised extraction procedure was applied to different types of soil with an organic carbon content of 0.4-16.7%. Besides freshly spiked soil samples, method validation included the analysis of samples with aged residues. A comparative study between the applicability of RPLC-UV without and with the use of column switching for the processing of uncleaned extracts, was carried out. For some of the tested analyte/matrix combinations the one-column approach (LC mode) is feasible. In comparison to LC, coupled-column LC (LC-LC mode) provides high selectivity in single-residue analysis (linuron) and, although less pronounced in multi-residue analysis (all six phenylurea herbicides), the clean-up performance of LC-LC improves both time of analysis and sample throughput. In the MRM approach the developed procedure involving MASE and LC-LC-UV provided acceptable recoveries (range, 80-120%) and RSDs (<12%) at levels of 10 microg/kg (n=9) and 50 microg/kg (n=7), respectively, for most analyte/matrix combinations. Recoveries from aged residue samples spiked at a level of 100 microg/kg (n=7) ranged, depending of the analyte/soil type combination, from 41-113% with RSDs ranging from 1-35%. In the SRM approach the developed LC-LC procedure was applied for the determination of linuron in 28 sandy soil samples collected in a field study. Linuron could be determined in soil with a limit of quantitation of 10 microg/kg.
Cronly, Mark; Behan, P; Foley, B; Malone, E; Earley, S; Gallagher, M; Shearan, P; Regan, L
2010-12-01
A confirmatory method has been developed to allow for the analysis of fourteen prohibited medicinal additives in pig and poultry compound feed. These compounds are prohibited for use as feed additives although some are still authorised for use in medicated feed. Feed samples are extracted by acetonitrile with addition of sodium sulfate. The extracts undergo a hexane wash to aid with sample purification. The extracts are then evaporated to dryness and reconstituted in initial mobile phase. The samples undergo an ultracentrifugation step prior to injection onto the LC-MS/MS system and are analysed in a run time of 26 min. The LC-MS/MS system is run in MRM mode with both positive and negative electrospray ionisation. The method was validated over three days and is capable of quantitatively analysing for metronidazole, dimetridazole, ronidazole, ipronidazole, chloramphenicol, sulfamethazine, dinitolimide, ethopabate, carbadox and clopidol. The method is also capable of qualitatively analysing for sulfadiazine, tylosin, virginiamycin and avilamycin. A level of 100 microg kg(-1) was used for validation purposes and the method is capable of analysing to this level for all the compounds. Validation criteria of trueness, precision, repeatability and reproducibility along with measurement uncertainty are calculated for all analytes. Copyright (c) 2010 Elsevier B.V. All rights reserved.
Du, Jiangbo; Ma, Zhiyu; Zhang, Yifan; Wang, Ting; Chen, Xiaoyan; Zhong, Dafang
2014-09-01
Ornidazole is a 5-nitroimidazole antimicrobial agent used for almost 40 years. A novel LC-MS/MS assay was developed and validated for the simultaneous determination of ornidazole and its main metabolites (M3, M6, M16-1, and M16-2) in human plasma. After extraction from 100 μl of plasma by protein precipitation with acetonitrile, all the analytes were separated on a Capcell PAK MG C18 column (100 × 4.6 mm, 5 μm) within 5.0 min and detected by ESI-MS/MS in the positive mode. The validation results met the acceptance criteria as per the US FDA and EMA guidelines. The validated method was successfully applied to a pharmacokinetic study after oral administration of 1000 mg ornidazole to six healthy Chinese volunteers.
Giebułtowicz, Joanna; Piotrowski, Roman; Baran, Jakub; Kułakowski, Piotr; Wroczyński, Piotr
2016-05-10
Antazoline is a first-generation antihistaminic agent with antiarrhythmic quinidine-like properties. In some countries, it is widely used for termination of cardiac arrhythmias, especially atrial fibrillation (AF). However, no human pharmacokinetic studies have been conducted with intravenous antazoline. The aim of our study was to develop and validate a novel liquid chromatography/tandem mass spectrometry (LC-MS/MS) method for the determination of antazoline in human plasma: the ELEPHANT-I [ELEctrophysiological, pharmacokinetic and hemodynamic effects of PHenazolinum (ANTazoline mesylate)] human pharmacokinetic study. Antazoline was extracted from plasma using liquid-liquid extraction. The concentration of the analyte was measured by LC-MS/MS with xylometazoline as an internal standard. The method was validated for linearity, precision, accuracy, stability (freeze/thaw stability, stability in autosampler, short and long term stability), dilution integrity and matrix effect. The analyzed validation criteria were fulfilled. The method was applied to a pharmacokinetic study involving 10 healthy volunteers. Following a single intravenous dose of antazoline mesylate (100 mg), the plasma concentration profile showed a relative fast elimination with a terminal elimination half-life of 2.29 h. A relatively high volume of distribution was observed (Vss=315 L). The values of mean residence time (MRT∞), area under the curve (AUC∞) and clearance were 3.45 h, 0.91 mg h L(-1) and 80.5 L h(-1), respectively. One volunteer showed significant differences in pharmacokinetic parameters. In conclusion, the proposed new LC-MS/MS method was successfully used for the first time for the determination of antazoline in human plasma. Copyright © 2016 Elsevier B.V. All rights reserved.
Method and platform standardization in MRM-based quantitative plasma proteomics.
Percy, Andrew J; Chambers, Andrew G; Yang, Juncong; Jackson, Angela M; Domanski, Dominik; Burkhart, Julia; Sickmann, Albert; Borchers, Christoph H
2013-12-16
There exists a growing demand in the proteomics community to standardize experimental methods and liquid chromatography-mass spectrometry (LC/MS) platforms in order to enable the acquisition of more precise and accurate quantitative data. This necessity is heightened by the evolving trend of verifying and validating candidate disease biomarkers in complex biofluids, such as blood plasma, through targeted multiple reaction monitoring (MRM)-based approaches with stable isotope-labeled standards (SIS). Considering the lack of performance standards for quantitative plasma proteomics, we previously developed two reference kits to evaluate the MRM with SIS peptide approach using undepleted and non-enriched human plasma. The first kit tests the effectiveness of the LC/MRM-MS platform (kit #1), while the second evaluates the performance of an entire analytical workflow (kit #2). Here, these kits have been refined for practical use and then evaluated through intra- and inter-laboratory testing on 6 common LC/MS platforms. For an identical panel of 22 plasma proteins, similar concentrations were determined, regardless of the kit, instrument platform, and laboratory of analysis. These results demonstrate the value of the kit and reinforce the utility of standardized methods and protocols. The proteomics community needs standardized experimental protocols and quality control methods in order to improve the reproducibility of MS-based quantitative data. This need is heightened by the evolving trend for MRM-based validation of proposed disease biomarkers in complex biofluids such as blood plasma. We have developed two kits to assist in the inter- and intra-laboratory quality control of MRM experiments: the first kit tests the effectiveness of the LC/MRM-MS platform (kit #1), while the second evaluates the performance of an entire analytical workflow (kit #2). In this paper, we report the use of these kits in intra- and inter-laboratory testing on 6 common LC/MS platforms. This article is part of a Special Issue entitled: Standardization and Quality Control in Proteomics. © 2013.
Grigori, Katerina; Loukas, Yannis L; Malenović, Anđelija; Samara, Vicky; Kalaskani, Anastasia; Dimovasili, Efi; Kalovidouri, Magda; Dotsikas, Yannis
2017-10-25
A sensitive Liquid Chromatography tandem mass spectrometry (LC-MS/MS) method was developed and validated for the quantitative analysis of three potential genotoxic impurities (318BP, M9, S5) in meropenem Active Pharmaceutical Ingredient (API). Due to the requirement for LOD values in ppb range, a high concentration of meropenem API (30mg/mL) had to be injected. Therefore, efficient determination of meropenem from its impurities became a critical aim of this study, in order to divert meropenem to waste, via a switching valve. After the selection of the important factors affecting analytes' elution, a Box-Behnken design was utilized to set the plan of experiments conducted with UV detector. As responses, the separation factor s between the last eluting impurity and meropenem, as well as meropenem retention factor k were used. Grid point search methodology was implemented aiming to obtain the optimal conditions that simultaneously comply to the conflicted criteria. Optimal mobile phase consisted of ACN, methanol and 0.09% HCOOH at a ratio 71/3.5/15.5v/v. All impurities and internal standard omeprazole were eluted before 7.5min and at 8.0min the eluents were directed to waste. The protocol was transferred to LC-MS/MS and validated according to ICH guidelines. Copyright © 2017 Elsevier B.V. All rights reserved.
MacMahon, Shaun; Ridge, Clark D; Begley, Timothy H
2014-12-03
A new analytical method has been developed and validated for the detection and quantification of 2-monochloropropanediol (2-MCPD) esters in edible oils. The target compounds are potentially carcinogenic contaminants formed during the processing of edible oils. As the 2-MCPD esters that occur most frequently in refined edible oils were not commercially available, standards were synthesized with identity and purity (95+%) confirmed by liquid chromatography-tandem mass spectrometry (LC-MS/MS) and (1)H NMR. Target analytes are separated from edible oil matrices using a two-step solid-phase extraction (SPE) procedure. The extracts are then analyzed using LC-MS/MS with electrospray ionization (ESI). The method has been validated for 11 2-MCPD diesters and 3 2-MCPD monoesters in soybean oil, olive oil, and palm oil using an external calibration curve. The ranges of average recoveries and relative standard deviations (RSD) across the three oil matrices at three spiking concentrations are 79-106% (3-13% RSD) for the 2-MCPD diesters and 72-108% (4-17% RSD) for the 2-MCPD monoesters, with limits of quantitation at or below 30 ng/g for the diesters and 90 ng/g for the monoesters.
Desmarchelier, Aurélien; Anizan, Sébastien; Minh Tien, Mai; Savoy, Marie-Claude; Bion, Cindy
2018-04-01
An LC-MS/MS method is presented for screening five tetracyclines and their epimers in a broad range of food products. The scope of matrices includes meat-, fish-, seafood-based products, various dairy ingredients, infant formulae and fats. The method principle is based on a liquid-liquid extraction with aqueous ethylenediaminetetraacetic acid (EDTA) and acetonitrile followed by a freezing step to promote phase separation at low temperature. After defatting with hexane, sample extracts were evaporated and reconstituted before injection onto the LC-MS/MS system. The addition of oxalic acid in the aqueous mobile phase was mandatory to maintain good peak shape and sensitivity over the run. The screening is based upon a double preparation of each sample, one 'as such' and a second one with the analytes spiked in the sample, in order to mitigate the risk of false negative response. The method was validated according to the European Community Reference Laboratories Residues Guidelines. A total of 93 samples were included in the validation by two independent laboratories giving both false-negative and false-positive rates at 0% for all compounds. Over the last two years, 2600 samples were analysed routinely and only one chicken sample was found above the regulatory limit.
van Nuland, M; Hillebrand, M J X; Rosing, H; Burgers, J A; Schellens, J H M; Beijnen, J H
2018-03-20
In microdose clinical trials a maximum of 100 μg of drug substance is administered to participants, in order to determine the pharmacokinetic properties of the agents. Measuring low plasma concentrations after administration of a microdose is challenging and requires the use of ulta-sensitive equipment. Novel liquid chromatography-mass spectrometry (LC-MS/MS) platforms can be used for quantification of low drug plasma levels. Here we describe the development and validation of an LC-MS/MS method for quantification of gemcitabine and its metabolite 2',2'-difluorodeoxyuridine (dFdU) in the low picogram per milliliter range to support a microdose trial. The validated assay ranges from 2.5-500 pg/mL for gemcitabine and 250-50,000 pg/mL for dFdU were linear, with a correlation coefficient (r 2 ) of 0.996 or better. Sample preparation with solid phase extraction provided a good and reproducible recovery. All results were within the acceptance criteria of the latest US FDA guidance and EMA guidelines. In addition, the method was successfully applied to measure plasma concentrations of gemcitabine in a patient after administration of a microdose of gemcitabine. Copyright © 2017 Elsevier B.V. All rights reserved.
Zou, Quanfei; Gu, Yuan; Lu, Rong; Zhang, Tiejun; Zhao, Guang-Rong; Liu, Changxiao; Si, Duanyun
2013-09-01
In this study, a simple and sensitive LC/MS/MS method was developed and validated for the determination of arctigenin in rat plasma. The MS detection was performed using multiple reaction monitoring at the transitions of m/z 373.2 → 137.3 for arctigenin and m/z 187.1 → 131.0 for psoralen (internal standard) with a Turbo IonSpray electrospray in positive mode. The calibration curves fitted a good linear relationship over the concentration range of 0.2-500 ng/mL. It was found that arctigenin is not stable enough at both room temperature and -80 °C unless mixed with methanol before storage. The validated LC/MS/MS method was successfully applied for the pharmacokinetic study of arctigenin in rats. After intravenous injection of 0.3 mg/kg arctigenin injection to rats, the maximum concentration, half-life and area under the concentration-time curve were 323 ± 65.2 ng/mL, 0.830 ± 0.166 and 81.0 ± 22.1 h ng/mL, respectively. Copyright © 2013 John Wiley & Sons, Ltd.
Ratiometric analysis of Acridine Orange staining in the study of acidic organelles and autophagy.
Thomé, Marcos P; Filippi-Chiela, Eduardo C; Villodre, Emilly S; Migliavaca, Celina B; Onzi, Giovana R; Felipe, Karina B; Lenz, Guido
2016-12-15
Acridine Orange is a cell-permeable green fluorophore that can be protonated and trapped in acidic vesicular organelles (AVOs). Its metachromatic shift to red fluorescence is concentration-dependent and, therefore, Acridine Orange fluoresces red in AVOs, such as autolysosomes. This makes Acridine Orange staining a quick, accessible and reliable method to assess the volume of AVOs, which increases upon autophagy induction. Here, we describe a ratiometric analysis of autophagy using Acridine Orange, considering the red-to-green fluorescence intensity ratio (R/GFIR) to quantify flow cytometry and fluorescence microscopy data of Acridine-Orange-stained cells. This method measured with accuracy the increase in autophagy induced by starvation or rapamycin, and the reduction in autophagy produced by bafilomycin A1 or the knockdown of Beclin1 or ATG7. Results obtained with Acridine Orange, considering R/GFIR, correlated with the conversion of the unlipidated form of LC3 (LC3-I) into the lipidated form (LC3-II), SQSTM1 degradation and GFP-LC3 puncta formation, thus validating this assay to be used as an initial and quantitative method for evaluating the late step of autophagy in individual cells, complementing other methods. © 2016. Published by The Company of Biologists Ltd.
NASA Astrophysics Data System (ADS)
Al-Qaim, Fouad Fadhil; Abdullah, Md Pauzi; Othman, Mohamed Rozali
2013-11-01
In this work, a developed method using solid - phase extraction (SPE) followed by liquid chromatography - time of flight mass spectrometry (LC-ESI-TOF/MS) was developed and validated for quantification and confirmation of eleven pharmaceuticals with different therapeutic classes in water samples, Malaysia. These compounds are caffeine (CAF), prazosin (PRZ), enalapril (ENL), carbamazepine (CBZ), nifedipine (NFD), levonorgestrel (LNG), simvastatin (SMV), hydrochlorothiazide (HYD), gliclazide (GLIC), diclofenac-Na (DIC-Na) and mefenamic acid (MEF). LC was performed on a Dionex Ultimate 3000/LC 09115047 (USA) system. Chromatography was performed on a Thermo Scientific C18 (250 mm × 2.1 mm, i.d.: 5μm) column. Several parameters were optimised such as; mobile phase, gradient elution, collision energy and solvent elution for extraction of compounds from water. The recoveries obtained ranged from 30-148 % in river water. Five pharmaceutical compounds were detected in the surface water samples: caffeine, prazosin, enalpril, diclofenac-Na and mefenamic acid. The developed method is precise and accepted recoveries were got. In addition, this method is suitable to identify and quantify trace concentrations of pharmaceuticals in surface water.
Landscape capability models as a tool to predict fine-scale forest bird occupancy and abundance
Loman, Zachary G.; DeLuca, William; Harrison, Daniel J.; Loftin, Cynthia S.; Rolek, Brian W.; Wood, Petra B.
2018-01-01
ContextSpecies-specific models of landscape capability (LC) can inform landscape conservation design. Landscape capability is “the ability of the landscape to provide the environment […] and the local resources […] needed for survival and reproduction […] in sufficient quantity, quality and accessibility to meet the life history requirements of individuals and local populations.” Landscape capability incorporates species’ life histories, ecologies, and distributions to model habitat for current and future landscapes and climates as a proactive strategy for conservation planning.ObjectivesWe tested the ability of a set of LC models to explain variation in point occupancy and abundance for seven bird species representative of spruce-fir, mixed conifer-hardwood, and riparian and wooded wetland macrohabitats.MethodsWe compiled point count data sets used for biological inventory, species monitoring, and field studies across the northeastern United States to create an independent validation data set. Our validation explicitly accounted for underestimation in validation data using joint distance and time removal sampling.ResultsBlackpoll warbler (Setophaga striata), wood thrush (Hylocichla mustelina), and Louisiana (Parkesia motacilla) and northern waterthrush (P. noveboracensis) models were validated as predicting variation in abundance, although this varied from not biologically meaningful (1%) to strongly meaningful (59%). We verified all seven species models [including ovenbird (Seiurus aurocapilla), blackburnian (Setophaga fusca) and cerulean warbler (Setophaga cerulea)], as all were positively related to occupancy data.ConclusionsLC models represent a useful tool for conservation planning owing to their predictive ability over a regional extent. As improved remote-sensed data become available, LC layers are updated, which will improve predictions.
Harun, Norlida; Anderson, Robert A; Miller, Eleanor I
2009-01-01
An ELISA and a liquid chromatography-tandem mass spectrometry (LC-MS-MS) confirmation method were developed and validated for the identification and quantitation of ketamine and its major metabolite norketamine in urine samples. The Neogen ketamine microplate ELISA was optimized with respect to sample and enzyme conjugate volumes and the sample preincubation time before addition of the enzyme conjugate. The ELISA kit was validated to include an assessment of the dose-response curve, intra- and interday precision, limit of detection (LOD), and cross-reactivity. The sensitivity and specificity were calculated by comparison to the results from the validated LC-MS-MS confirmation method. An LC-MS-MS method was developed and validated with respect to LOD, lower limit of quantitation (LLOQ), linearity, recovery, intra- and interday precision, and matrix effects. The ELISA dose-response curve was a typical S-shaped binding curve, with a linear portion of the graph observed between 25 and 500 ng/mL for ketamine. The cross-reactivity of 200 ng/mL norketamine to ketamine was 2.1%, and no cross-reactivity was detected with 13 common drugs tested at 10,000 ng/mL. The ELISA LOD was calculated to be 5 ng/mL. Both intra- (n = 10) and interday (n = 50) precisions were below 5.0% at 25 ng/mL. The LOD for ketamine and norketamine was calculated statistically to be 0.6 ng/mL. The LLOQ values were also calculated statistically and were 1.9 ng/mL and 2.1 ng/mL for ketamine and norketamine, respectively. The test linearity was 0-1200 ng/mL with correlation coefficient (R(2)) > 0.99 for both analytes. Recoveries at 50, 500, and 1000 ng/mL range from 97.9% to 113.3%. Intra- (n = 5) and interday (n = 25) precisions between extracts for ketamine and norketamine were excellent (< 10%). Matrix effects analysis showed an average ion suppression of 5.7% for ketamine and an average ion enhancement of 13.0% for norketamine for urine samples collected from six individuals. A comparison of ELISA and LC-MS-MS results demonstrated a sensitivity, specificity, and efficiency of 100%. These results indicated that a cutoff value of 25 ng/mL ketamine in the ELISA screen is particularly suitable and reliable for urine testing in a forensic toxicology setting. Furthermore, both ketamine and norketamine were detected in all 34 urine samples collected from individuals socializing in pubs by the Royal Malaysian Police. Ketamine concentrations detected by LC-MS-MS ranged from 22 to 31,670 ng/mL, and norketamine concentrations ranged from 25 to 10,990 ng/mL. The concentrations of ketamine and norketamine detected in the samples are most ikely indicative of ketamine abuse.
Ayoub, Bassam M; Mowaka, Shereen; Elzanfaly, Eman S; Ashoush, Nermeen; Elmazar, Mohamed M; Mousa, Shaker A
2017-05-31
The present study considered the pharmacokinetic evaluation of empagliflozin after administration to Egyptian volunteers, and the results were compared with other ethnic populations. The FDA recognizes that standard methods of defining racial subgroups are necessary to compare results across pharmacokinetic studies and to assess potential subgroup differences. The design of the study was as an open labeled, randomized, one treatment, one period, single dose pharmacokinetic study. The main pharmacokinetic parameters estimated were C max , T max , t 1/2 , elimination rate constant, AUC 0-t and AUC 0-inf . The insignificant difference in pharmacokinetic parameters between Egyptians and white German subjects suggests that no dose adjustment should be considered with administration of 25 mg empagliflozin to Egyptian population. A new LC-MS/MS method was developed and validated, allowing sensitive estimation of empagliflozin (25-600 ng mL -1 ) in human plasma using dapagliflozin as an internal standard (IS). The method was applied successfully on the underlying pharmacokinetic study with enhanced sample preparation that involved liquid-liquid extraction. Multiple Reaction Monitoring (MRM) of the transition pairs of m/z 449.01 to 371.21 for empagliflozin and m/z 407.00 to 328.81 for dapagliflozin (IS) was employed utilizing negative mode Electro Spray Ionization (ESI). The validated LC-MS/MS method is suitable for further toxicodynamic and bioequivalence studies.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Owens, J; Hok, S; Alcaraz, A
Tetramethylenedisulfotetramine, commonly known as tetramine, is a highly neurotoxic rodenticide (human oral LD{sub 50} = 0.1 mg/kg) used in hundreds of deliberate food poisoning events in China. Here we describe a method for quantitation of tetramine spiked into beverages, including milk, juice, tea, cola, and water and cleaned up by C8 solid phase extraction and liquid-liquid extraction. Quantitation by high performance liquid chromatography tandem mass spectrometry (LC/MS/MS) was based upon fragmentation of m/z 347 to m/z 268. The method was validated by gas chromatography mass spectrometry (GC/MS) operated in SIM mode for ions m/z 212, 240, and 360. The limitmore » of quantitation was 0.10 {micro}g/mL by LC/MS/MS versus 0.15 {micro}g/mL for GC/MS. Fortifications of the beverages at 2.5 {micro}g/mL and 0.25 {micro}g/mL were recovered ranging from 73-128% by liquid-liquid extraction for GC/MS analysis, 13-96% by SPE and 10-101% by liquid-liquid extraction for LC/MS/MS analysis.« less
Ellingson, David J; Shippar, Jeffrey J; Gilmore, Justin M
2016-01-01
Analytical methods for the analysis of both L-carnitine and choline are needed for reliable and accurate determination in infant formula and adult/pediatric nutritional formula. These compounds are different in how they are utilized by the human body, but are structurally similar. L-carnitine and choline are quaternary ammonium compounds, enabling both to be retained under acidic conditions with strong cation exchange (SCX) chromatography. This method analyzes both compounds simultaneously as either the free forms or as a total amount that includes bound sources such as phosphatidylcholine or acetylcarnitine. The free analysis consists of water extraction and analysis by LC/MS/MS, while the total analysis consists of extraction by acid assisted microwave hydrolysis and analysis by LC/MS/MS. Calibration standards used for calculations are extracted with all samples in the batch. A single laboratory validation (SLV) was performed following the guidelines of the AOAC Stakeholder Panel on Infant Formula and Adult Nutritionals (SPIFAN) utilizing the kit of materials provided. The results achieved meet the requirements of SMPR 2012.010 and 2012.013 for L-carnitine and total choline, respectively.
Detection of levamisole exposure in cocaine users by liquid chromatography-tandem mass spectrometry.
Lynch, Kara L; Dominy, Stephen S; Graf, Jonathan; Kral, Alexander H
2011-04-01
Levamisole, a veterinary antihelminthic, was recently recognized as an adulterant in cocaine and is known to cause severe adverse reactions in some cocaine users. Because of the health concerns involving levamisole-adulterated cocaine, we developed a liquid chromatography-tandem mass spectrometry (LC-MS-MS) method for the detection of levamisole in urine. This method was used to determine the prevalence of levamisole in cocaine-positive patient samples. All cocaine-positive urine samples that were sent to the San Francisco General Hospital Clinical Laboratory were tested for levamisole for one month. For LC, an Agilent 1200 series was used with a C(18) column and a gradient of mobile phase A (0.05% formic acid) and B (acetonitrile/methanol). Detection was carried out with an Applied Biosystems QTRAP(®) LC-MS-MS. The levamisole LC-MS-MS method was linear over the range of 5-2500 ng/mL (r > 0.996). Interassay and intraassay CVs were < 6%. The lower limit of detection for levamisole was 0.5 ng/mL. Out of 949 total urine drug screens, 20% were positive for benzoylecgonine, and of those, 88% were positive for levamisole. The high prevalence of levamisole-adulterated cocaine and potential toxicity in cocaine users is a serious public health concern. These findings validate the utility of an LC-MS-MS method for the detection of levamisole.
Lowe, Aaron M.; Bertics, Paul J.; Abbott, Nicholas L.
2009-01-01
We report methods for the acquisition and analysis of optical images formed by thin films of twisted nematic liquid crystals (LCs) placed into contact with surfaces patterned with bio/chemical functionality relevant to surface-based assays. The methods are simple to implement and are shown to provide easily interpreted maps of chemical transformations on surfaces that are widely exploited in the preparation of analytic devices. The methods involve acquisition of multiple images of the LC as a function of the orientation of a polarizer; data analysis condenses the information present in the stack of images into a spatial map of the twist angle of the LC on the analytic surface. The potential utility of the methods is illustrated by mapping (i) the displacement of a monolayer formed from one alkanethiol on a gold film by a second thiol in solution, (ii) coadsorption of mixtures of amine-terminated and ethyleneglycol-terminated alkanethiols on gold films, which leads to a type of mixed monolayer that is widely exploited for immobilization of proteins on analytic surfaces, and (iii) patterns of antibodies printed onto surfaces. These results show that maps of the twist angle of the LC constructed from families of optical images can be used to reveal surface features that are not apparent in a single image of the LC film. Furthermore, the twist angles of the LC can be used to quantify the energy of interaction of the LC with the surface with a spatial resolution of <10 µm. When combined, the results described in this paper suggest non-destructive methods to monitor and validate chemical transformations on surfaces of the type that are routinely employed in the preparation of surface-based analytic technologies. PMID:18355089
Uclés, A; Ulaszewska, M M; Hernando, M D; Ramos, M J; Herrera, S; García, E; Fernández-Alba, A R
2013-07-01
This work introduces a liquid chromatography-electrospray ionization-hybrid quadrupole/time-of-flight mass spectrometry (LC-ESI-QTOF-MS)-based method for qualitative and quantitative analysis of poly(amidoamine) (PAMAM) dendrimers of generations 0 to 3 in an aqueous matrix. The multiple charging of PAMAM dendrimers generated by means of ESI has provided key advantages in dendrimer identification by assignation of charge state through high resolution of isotopic clusters. Isotopic distribution in function of abundance of isotopes (12)C and (13)C yielded valuable and complementarity data for confident characterization. A mass accuracy below 3.8 ppm for the most abundant isotopes (diagnostic ions) provided unambiguous identification of PAMAM dendrimers. Validation of the LC-ESI-QTOF-MS method and matrix effect evaluation enabled reliable and reproducible quantification. The validation parameters, limits of quantification in the range of 0.012 to 1.73 μM, depending on the generation, good linear range (R > 0.996), repeatability (RSD < 13.4%), and reproducibility (RSD < 10.9%) demonstrated the suitability of the method for the quantification of dendrimers in aqueous matrices (water and wastewater). The added selectivity, achieved by multicharge phenomena, represents a clear advantage in screening aqueous mixtures due to the fact that the matrix had no significant effect on ionization, with what is evidenced by an absence of sensitivity loss in most generations of PAMAM dendrimers. Fig Liquid chromatography-electrospray ionization-hybrid quadrupole/time of flight mass spectrometry (LC-ESI-QTOF-MS) based method for qualitative and quantitative analysis of PAMAM dendrimers in aqueous matrix.
Maas, Alexandra; Maier, Christoph; Iwersen-Bergmann, Stefanie; Madea, Burkhard; Hess, Cornelius
2017-11-30
Besides its clinical application, the anaesthetic agent propofol is being increasingly misused, mostly by healthcare professionals, and its abuse potential gained worldwide attention after the tragic death of Michael Jackson in 2009. Due to the short duration of its narcotic effects, propofol abuse is especially easy to hide compared with the use of other recreational drugs. However, propofol possesses a very narrow therapeutic window between the desired effect and potentially fatal toxicity, making abuse of the drug extremely dangerous even in experienced physicians. Consequently, it is important that forensic laboratories possess a sensitive and specific method for the detection of chronic propofol abuse. We present a simple, fast and reliable method to simultaneously extract propofol and its main metabolite propofol glucuronide from hair, followed by sensitive LC-MS/MS analyses, allowing to determine a chronic propofol abuse. Difficulties regarding the detection of propofol using LC-MS/MS were solved by using a derivatization reaction with 2-fluoro-1-methylpyridinium-p-toluene-sulfonate and triethylamine. Reliability of extraction method and subsequent LC-MS/MS analyses was confirmed under consideration of the validation parameters selectivity, linearity, accuracy and precision, analytical limits, processed sample stability, matrix effects and recovery. Appropriate quantification (LLOQ=10pg/mg hair) and detection limits (3.6pg/mg hair for propofol and 7.8 pg/mg hair for propofol glucuronide) could be achieved, enabling to detect even small amounts of both analytes. Applicability of the method was confirmed by analysis of three human hair samples from deceased with suspicion of chronic propofol abuse. Copyright © 2017 Elsevier B.V. All rights reserved.
Frank, Nancy; Bessaire, Thomas; Tarres, Adrienne; Goyon, Alexandre; Delatour, Thierry
2017-11-01
The increasing number of food frauds using exogenous nitrogen-rich adulterants to artificially raise the protein content for economically motivated adulteration has demonstrated the need for a robust analytical methodology. This method should be applicable for quality control in operations covering a wide range of analyte concentrations to be able to analyse high levels as usually found in adulteration, as well as low levels due to contamination. The paper describes a LC-MS/MS method covering 14 nitrogen-rich adulterants using a simple and fast sample preparation based on dilution and clean-up by dispersive SPE. Quantification is carried out by isotopic dilution reaching LOQs of 0.05-0.20 mg/kg in a broad range of food matrices (infant formula, liquid milk, dairy ingredient, high protein meal, cereal, infant cereal, and meat/fish powder). Validation of seven commodity groups was performed according to SANCO 12571/2013, giving satisfactory results demonstrating the method's fitness for purpose at the validated range at contamination level. Method ruggedness was further assessed by transferring the developed method into another laboratory devoted to routine testing for quality control. Next to the method description, emphasis is placed on challenges and problems appearing during method development as well as validation. They are discussed in detail and solutions are provided.
A computer method of finding valuations forcing validity of LC formulae
NASA Astrophysics Data System (ADS)
Godlewski, Łukasz; Świetorzecka, Kordula; Mulawka, Jan
2014-11-01
The purpose of this paper is to present the computer implementation of a system known as LC temporal logic [1]. Firstly, to become familiar with some theoretical issues, a short introduction to this logic is discussed. The algorithms allowing a deep analysis of the formulae of LC logic are considered. In particular we discuss how to determine if a formula is a tautology, contrtautology or it is satisfable. Next, we show how to find all valuations to satisfy the formula. Finally, we consider finding histories generated by the formula and transforming these histories into the state machine. Moreover, a description of the experiments that verify the implementation are briefly presented.
Zhang, Jingjing; Liang, Jiabi; Tian, Yuan; Zhang, Zunjian; Chen, Yun
2007-10-15
A rapid, sensitive and selective LC-MS/MS method was developed and validated for the quantification of aniracetam in human plasma using estazolam as internal standard (IS). Following liquid-liquid extraction, the analytes were separated using a mobile phase of methanol-water (60:40, v/v) on a reverse phase C18 column and analyzed by a triple-quadrupole mass spectrometer in the selected reaction monitoring (SRM) mode using the respective [M+H]+ ions, m/z 220-->135 for aniracetam and m/z 295-->205 for the IS. The assay exhibited a linear dynamic range of 0.2-100 ng/mL for aniracetam in human plasma. The lower limit of quantification (LLOQ) was 0.2 ng/mL with a relative standard deviation of less than 15%. Acceptable precision and accuracy were obtained for concentrations over the standard curve range. The validated LC-MS/MS method has been successfully applied to study the pharmacokinetics of aniracetam in healthy male Chinese volunteers.
de-Torres, Juan P; Wilson, David O; Sanchez-Salcedo, Pablo; Weissfeld, Joel L; Berto, Juan; Campo, Arantzazu; Alcaide, Ana B; García-Granero, Marta; Celli, Bartolome R; Zulueta, Javier J
2015-02-01
Patients with chronic obstructive pulmonary disease (COPD) are at high risk for lung cancer (LC) and represent a potential target to improve the diagnostic yield of screening programs. To develop a predictive score for LC risk for patients with COPD. The Pamplona International Early Lung Cancer Detection Program (P-IELCAP) and the Pittsburgh Lung Screening Study (PLuSS) databases were analyzed. Only patients with COPD on spirometry were included. By logistic regression we determined which factors were independently associated with LC in PLuSS and developed a COPD LC screening score (COPD-LUCSS) to be validated in P-IELCAP. By regression analysis, age greater than 60, body mass index less than 25 kg/m(2), pack-years history greater than 60, and emphysema presence were independently associated with LC diagnosis and integrated into the COPD-LUCSS, which ranges from 0 to 10 points. Two COPD-LUCSS risk categories were proposed: low risk (scores 0-6) and high risk (scores 7-10). In comparison with low-risk patients, in both cohorts LC risk increased 3.5-fold in the high-risk category. The COPD-LUCSS is a good predictor of LC risk in patients with COPD participating in LC screening programs. Validation in two different populations adds strength to the findings.
Mezzullo, Marco; Fanelli, Flaminia; Fazzini, Alessia; Gambineri, Alessandra; Vicennati, Valentina; Di Dalmazi, Guido; Pelusi, Carlotta; Mazza, Roberta; Pagotto, Uberto; Pasquali, Renato
2016-10-01
Salivary steroid testing represents a valuable source of biological information; however, the proper measurement of low salivary levels is challenging for direct immunoassays, lacking adequate sensitivity and specificity and causing poor inter-laboratory reproducibility. Liquid chromatography-tandem mass spectrometry (LC-MS/MS) has overcome previous analytical limits, often providing results deviating from previous knowledge. Nowadays, LC-MS/MS is being introduced in clinical laboratories for salivary cortisol testing; however, so far only a few studies have reported thorough biological validation based on LC-MS/MS data. In this study, we provide a thorough analytical, pre-analytical and biological validation of an LC-MS/MS method for the measurement of salivary cortisol (F) and of its inactive metabolite cortisone (E). Analytes were extracted from 50μl of saliva, were then separated in 7.5min LC-gradient and detected by negative electrospray ionization-multiple reaction monitoring. The reliability of a widely diffused collection device, Salivette(®), was assessed and the overall procedure was validated. The diurnal cortisol and cortisone fluctuation in saliva and serum was described by a four paired collection protocol (8 am, 12 am, 4 pm and 8 pm) in 19 healthy subjects. The assay allowed the quantitation of F and E down to 39.1 and 78.1pg/ml, with an imprecision range of 5.5-9.5%, 3.9-14.1% and 2.6-14.4%, and an accuracy range of 105.5-113.1%, 88.5-98.7% and 90.7-96.7% for both analytes at low, medium and high levels, respectively. Salivette(®) provided comparable results and better precision (CV<1.0%) as referred to direct spitting (CV<13.0%). A parallel diurnal rhythm in saliva and serum was observed for cortisol and cortisone, with values lowering from the morning to the evening time points (P<0.0001). While salivary E linearly correlated to total serum F (R(2)=0.854, P<0.001), salivary F showed an exponential relationship (R(2)=0.903, P<0.001) with serum F reflecting the free circulating fraction. A non linear association between E and F was observed in saliva (R(2)=0.941, p<0.001) consistent with the type II 11β-HSD activity. We concluded that our LC-MS/MS method allowed a sensitive evaluation of salivary levels of cortisol and cortisone. The simultaneous determination of both hormones in saliva allowed the differential estimation of the active and of the total glucocorticoid exposure over the daytime. The assay could provide further insight into the comprehension of normal and dysfunctional glucocorticoid circadian rhythm. Copyright © 2016 Elsevier Ltd. All rights reserved.
In 't Veld, P H; van der Laak, L F J; van Zon, M; Biesta-Peters, E G
2018-04-12
A method for the quantification of the Bacillus cereus emetic toxin (cereulide) was developed and validated. The method principle is based on LC-MS as this is the most sensitive and specific method for cereulide. Therefore the study design is different from the microbiological methods validated under this mandate. As the method had to be developed a two stage validation study approach was used. The first stage (pre-study) focussed on the method applicability and the experience of the laboratories with the method. Based on the outcome of the pre-study and comments received during voting at CEN and ISO level a final method was agreed to be used for the second stage the (final) validation of the method. In the final (validation) study samples of cooked rice (both artificially contaminated with cereulide or contaminated with B. cereus for production of cereulide in the rice) and 6 other food matrices (fried rice dish, cream pastry with chocolate, hotdog sausage, mini pancakes, vanilla custard and infant formula) were used. All these samples were spiked by the participating laboratories using standard solutions of cereulide supplied by the organising laboratory. The results of the study indicate that the method is fit for purpose. Repeatability values were obtained of 0.6 μg/kg at low level spike (ca. 5 μg/kg) and 7 to 9.6 μg/kg at high level spike (ca. 75 μg/kg). Reproducibility at low spike level ranged from 0.6 to 0.9 μg/kg and from 8.7 to 14.5 μg/kg at high spike level. Recovery from the spiked samples ranged between 96.5% for mini-pancakes to 99.3% for fries rice dish. Copyright © 2018. Published by Elsevier B.V.
Xiong, Yeping; Zhao, Yuan-Yuan; Goruk, Sue; Oilund, Kirsten; Field, Catherine J; Jacobs, René L; Curtis, Jonathan M
2012-12-12
A hydrophilic interaction liquid chromatography-tandem mass spectrometry (HILIC LC-MS/MS) method was developed and validated to simultaneously quantify six aqueous choline-related compounds and eight major phospholipids classes in a single run. HILIC chromatography was coupled to positive ion electrospray mass spectrometry. A combination of multiple scan modes including precursor ion scan, neutral loss scan and multiple reaction monitoring was optimized for the determination of each compound or class in a single LC/MS run. This work developed a simplified extraction scheme in which both free choline and related compounds along with phospholipids were extracted into a homogenized phase using chloroform/methanol/water (1:2:0.8) and diluted into methanol for the analysis of target compounds in a variety of sample matrices. The analyte recoveries were evaluated by spiking tissues and food samples with two isotope-labeled internal standards, PC-d(3) and Cho-d(3). Recoveries of between 90% and 115% were obtained by spiking a range of sample matrices with authentic standards containing all 14 of the target analytes. The precision of the analysis ranged from 1.6% to 13%. Accuracy and precision was comparable to that obtained by quantification of selected phospholipid classes using (31)P NMR. A variety of sample matrices including egg yolks, human diets and animal tissues were analyzed using the validated method. The measurements of total choline in selected foods were found to be in good agreement with values obtained from the USDA choline database. Copyright © 2012 Elsevier B.V. All rights reserved.
Park, Min-Ho; Lee, Yun Young; Cho, Kyung Hee; La, Sookie; Lee, Hee Joo; Yim, Dong-Seok; Ban, Sooho; Park, Moon-Young; Kim, Yong-Chul; Kim, Yoon-Gyoon; Shin, Young G
2016-03-01
A liquid chromatography-triple quadrupole mass spectrometric (LC-MS/MS) method was developed and validated for the determination of 5-nitro-5'-hydroxy-indirubin-3'-oxime (AGM-130) in human plasma to support a microdose clinical trial. The method consisted of a liquid-liquid extraction for sample preparation and LC-MS/MS analysis in the positive ion mode using TurboIonSpray(TM) for analysis. d3 -AGM-130 was used as the internal standard. A linear regression (weighted 1/concentration) was used to fit calibration curves over the concentration range of 10-2000 pg/mL for AGM-130. There were no endogenous interference components in the blank human plasma tested. The accuracy at the lower limit of quantitation was 96.6% with a precision (coefficient of variation, CV) of 4.4%. For quality control samples at 30, 160 and 1600 pg/mL, the between run CV was ≤5.0 %. Between-run accuracy ranged from 98.1 to 101.0%. AGM-130 was stable in 50% acetonitrile for 168 h at 4°C and 6 h at room temperature. AGM-130 was also stable in human plasma at room temperature for 6 h and through three freeze-thaw cycles. The variability of selected samples for the incurred sample reanalysis was ≤12.7% when compared with the original sample concentrations. This validated LC-MS/MS method for determination of AGM-130 was used to support a phase 0 microdose clinical trial. Copyright © 2015 John Wiley & Sons, Ltd.
Parsons, Teresa L.; Emory, Joshua F.; Seserko, Lauren A.; Aung, Wutyi S.; Marzinke, Mark A.
2014-01-01
Background Topical microbicidal agents are being actively pursued as a modality to prevent HIV viral transmission during sexual intercourse. Quantification of antiretroviral agents in specimen sources where antiviral activity is elicited is critical, and drug measurements in cervicovaginal fluid can provide key information on local drug concentrations. Two antiretroviral drugs, dapivirine and maraviroc, have gained interest as vaginal microbicidal agents, and rugged methods are required for their quantification in cervicovaginal secretions. Methods Cervicovaginal fluid spiked with dapivirine and maraviroc were applied to ophthalmic tear strips or polyester-based swabs to mimic collection procedures used in clinical studies. Following sample extraction and the addition of isotopically-labeled internal standards, samples were subjected to liquid chromatographic-tandem mass spectrometric (LC-MS/MS) analysis using a Waters BEH C8, 50 × 2.1 mm, 1.7 µm particle size column, on an API 4000 mass analyzer operated in selective reaction monitoring mode. The method was validated according to FDA Bioanalytical Method Validation guidelines. Results Due to the disparate saturation capacity of the tested collection devices, the analytical measuring ranges for dapivirine and maravirocin cervicovaginal fluid on the ophthalmic tear strip were 0.05 to 25 ng/tear strip, and 0.025 to 25 ng/tear strip, respectively. As for the polyester-based swab, the analytical measuring ranges were 0.25 to 125 ng/swab for dapivirine and 0.125 to 125 ng/swab for maraviroc. Dilutional studies were performed for both analytes to extended ranges of 25,000 ng/tear strip and 11,250 ng/swab. Standard curves were generated via weighted (1/x2) linear or quadratic regression of calibrators. Precision, accuracy, stability and matrix effects studies were all performed and deemed acceptable according to the recommendations of the FDA Bioanalytical Method Validation guidelines. Conclusions A rugged LC-MS/MS method for the dual quantification of dapivirine and maraviroc in cervicovaginal fluid using two unique collection devices has been developed and validated. The described method meets the criteria to support large research trials. PMID:25005891
Hubert, C; Houari, S; Rozet, E; Lebrun, P; Hubert, Ph
2015-05-22
When using an analytical method, defining an analytical target profile (ATP) focused on quantitative performance represents a key input, and this will drive the method development process. In this context, two case studies were selected in order to demonstrate the potential of a quality-by-design (QbD) strategy when applied to two specific phases of the method lifecycle: the pre-validation study and the validation step. The first case study focused on the improvement of a liquid chromatography (LC) coupled to mass spectrometry (MS) stability-indicating method by the means of the QbD concept. The design of experiments (DoE) conducted during the optimization step (i.e. determination of the qualitative design space (DS)) was performed a posteriori. Additional experiments were performed in order to simultaneously conduct the pre-validation study to assist in defining the DoE to be conducted during the formal validation step. This predicted protocol was compared to the one used during the formal validation. A second case study based on the LC/MS-MS determination of glucosamine and galactosamine in human plasma was considered in order to illustrate an innovative strategy allowing the QbD methodology to be incorporated during the validation phase. An operational space, defined by the qualitative DS, was considered during the validation process rather than a specific set of working conditions as conventionally performed. Results of all the validation parameters conventionally studied were compared to those obtained with this innovative approach for glucosamine and galactosamine. Using this strategy, qualitative and quantitative information were obtained. Consequently, an analyst using this approach would be able to select with great confidence several working conditions within the operational space rather than a given condition for the routine use of the method. This innovative strategy combines both a learning process and a thorough assessment of the risk involved. Copyright © 2015 Elsevier B.V. All rights reserved.
Narayana, M B V; Chandrasekhar, K B; Rao, B M
2014-09-01
A validated specific stability-indicating reverse-phase liquid chromatographic method was developed for the quantitative determination of Ambrisentan as well as its related substances in bulk samples, pharmaceutical dosage forms in the presence of degradation products and its related impurities. Forced degradation studies were performed on bulk samples of Ambrisentan as per the ICH-prescribed stress conditions using acid, base, oxidative, thermal stress and photolytic degradation to show the stability-indicating power of the LC method. Significant degradation in acidic, basic stress conditions was observed and no degradation was observed in other stress conditions. The chromatographic method was optimized using the samples generated from the forced degradation studies and the impurity-spiked solution. Good resolution between the peaks corresponds to Ambrisentan-related impurities and degradation products from the analyte were achieved on a SunFire C18 column using a mobile phase consisting of a mixture of potassium dihydrogen orthophosphate at a pH adjusted to 2.5 with ortho-phosphoric acid in water and a mixture of acetonitrile:methanol using a simple linear gradient. The detection was carried out at 225 nm. The limit of detection and the limit of quantification for the Ambrisentan and its related impurities were established. The stressed test solutions were assayed against the qualified working standard of Ambrisentan and the mass balance in each case was between 98.9 and 100.3%, indicating that the developed LC method was stability indicating. Validation of the developed LC method was carried out as per the ICH requirements. The developed method was found to be suitable to check the quality of bulk samples of Ambrisentan at the time of batch release and also during its storage (long-term and accelerated stability). © The Author [2013]. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.
Lalitha Devi, M; Chandrasekhar, K B
2009-12-05
The objective of current study was to develop a validated specific stability indicating reversed-phase liquid chromatographic method for the quantitative determination of levofloxacin as well as its related substances determination in bulk samples, pharmaceutical dosage forms in the presence of degradation products and its process related impurities. Forced degradation studies were performed on bulk sample of levofloxacin as per ICH prescribed stress conditions using acid, base, oxidative, water hydrolysis, thermal stress and photolytic degradation to show the stability indicating power of the method. Significant degradation was observed during oxidative stress and the degradation product formed was identified by LCMS/MS, slight degradation in acidic stress and no degradation was observed in other stress conditions. The chromatographic method was optimized using the samples generated from forced degradation studies and the impurity spiked solution. Good resolution between the peaks corresponds to process related impurities and degradation products from the analyte were achieved on ACE C18 column using the mobile phase consists a mixture of 0.5% (v/v) triethyl amine in sodium dihydrogen orthophosphate dihydrate (25 mM; pH 6.0) and methanol using a simple linear gradient. The detection was carried out at 294 nm. The limit of detection and the limit of quantitation for the levofloxacin and its process related impurities were established. The stressed test solutions were assayed against the qualified working standard of levofloxacin and the mass balance in each case was in between 99.4 and 99.8% indicating that the developed LC method was stability indicating. Validation of the developed LC method was carried out as per ICH requirements. The developed LC method was found to be suitable to check the quality of bulk samples of levofloxacin at the time of batch release and also during its stability studies (long term and accelerated stability).
Boison, Joe; Lee, Stephen; Gedir, Ron
2009-01-01
A liquid chromatographic-mass spectrometric (LC-MS) method was developed and validated for the determination and confirmation of virginiamycin (VMY) M1 residues in porcine liver, kidney, and muscle tissues at concentrations > or =2 ng/g. Porcine liver, kidney, or muscle tissue is homogenized with methanol-acetonitrile. After centrifugation, the supernatant is diluted with phosphate buffer and cleaned up on a C18 solid-phase extraction cartridge. VMY in the eluate is partitioned into chloroform and the aqueous upper layer is removed by aspiration. After evaporating the chloroform in the residual mixture to dryness, the dried extract is reconstituted in mobile phase and VMY is quantified by LC-MS. Any samples eliciting quantifiable levels of VMY M1 (i.e., at concentrations > or =2 ng/g) are subjected to confirmatory analysis by LC-MSIMS. VMY S1, a minor component of the VMY complex, is monitored but not quantified or confirmed.
Tache, Florentin; Farca, Alexandru; Medvedovici, Andrei; David, Victor
2002-05-15
Both derivatization of free captopril in human plasma samples using monobromobimane as fluorescent label and the corresponding HPLC-fluorescence detection (FLD) method were validated. Calibration curve for the fluorescent captopril derivative in plasma samples is linear in the ppb-ppm range with a detection limit of 4 ppb and an identification limit of 10 ppb (P%: 90; nu > or = 5). These methods were successfully applied on bioequivalence studies carried out on some marketed pharmaceutical formulations.
Yao, Chang-liang; Yang, Wen-zhi; Wu, Wan-Yyng; Da, Juan; Hou, Jin-jun; Zhang, Jing-xian; Zhang, Yan-hai; Jin, Yan; Yang, Min; Jiang, Bao-hong; Liu, Xuan; Guo, De-an
2015-07-10
Current China Pharmacopoeia (ChP) standards employ diversified and case-dependent assay methods to evaluate the quality of different Chinese patent medicines (CPMs) that contain Panax notoginseng as the monarch drug. These conventional, HPLC-based approaches, utilizing a complex sample preparation procedure, can easily result in low analytical efficiency and possible component loss. Here, a "monomethod-heterotrait matrix" (MHM) strategy is proposed, that is, developing a universal multi heart-cutting two-dimensional liquid chromatography (MHC-2D-LC) approach that facilitates the simultaneous quantitation of five P. notoginseng saponins (noto-R1, Re, Rg1, Rb1, and Rd) in eight different CPMs. The MHC-2D-LC system was constructed on a dual-gradient liquid chromatography instrument equipped with a Poroshell SB C18 column and a Zorbax SB-Aq column for respective (1)D and (2)D separation. Method validation was performed in terms of specificity, linearity (r(2) and F-test), intra-/inter-day precision (0.4-7.9%), stability (1.2-3.9%), and recovery (90.2-108.7%), and the LODs and LOQs (loaded masses) of the five analytes varied between 4.0-11.0ng and 6.0-33.0ng, respectively. The validated MHC-2D-LC approach was subsequently applied to quantify the five saponins in thirty batches of different CPMs. The method demonstrated superiority over the current ChP assay methods in respect of specificity (avoiding co-elution), resolution (Rs>1.5), sample preparation (easy-to-implement ultrasonic extraction without repeated re-extraction), and transfer rate (minimum component loss). This is the first application of an MHC-2D-LC method for the quantitative assessment of the constituents of CPMs. The MHM approach represents a new, strategically significant methodology for the quality control of CPMs that involve complex chemical matrix. Copyright © 2015 Elsevier B.V. All rights reserved.
Kovarikova, Petra; Pasakova-Vrbatova, Ivana; Vavrova, Anna; Stariat, Jan; Klimes, Jiri; Simunek, Tomas
2013-03-25
Dexrazoxane (DEX) is the only clinically used drug effective against anthracycline-induced cardiotoxicity and extravasation injury. However, the mechanism of its cardioprotective action still remains elusive. This paucity of comprehensive data is at least partially caused by the analytical difficulties associated with selective and sensitive simultaneous determination of the parent drug and its putative active metabolite ADR-925 in the relevant biological material. The aim of this study was to develop and validate the first LC-MS/MS method for simultaneous determination of DEX and ADR-925 in the isolated rat neonatal ventricular cardiomyocytes (NVCMs) and the cell culture medium. The analysis was performed on a Synergi Polar-RP column using the gradient profile of the mobile phase composed of 2mM ammonium formate and methanol. Electrospray ionization and ion trap mass analyzer were used as ionization and detection techniques, respectively. NVCMs were precipitated with methanol and the cell culture medium samples were diluted with the same solvent prior the LC-MS/MS analysis. The method was validated within the range of 4-80pmol/10(6) NVCMs and 7-70pmol/10(6) NVCMs for DEX and ADR-925, respectively, and at the concentrations of 8-100μM for both compounds in the culture cell medium. The practical applicability of this method was confirmed by the pilot analysis of NVCMs and the corresponding cell medium samples from relevant in vitro experiment. Hence, the LC-MS/MS method developed in this study represents a modern analytical tool suitable for investigation of DEX bioactivation inside the cardiomyocytes. In addition, the basic utility of the method for the analysis of DEX and ADR-925 in plasma samples was proved in a pilot experiment. Copyright © 2013 Elsevier B.V. All rights reserved.
NASA Astrophysics Data System (ADS)
Zhang, Rui; Roberts, Tyler; de Pablo, Juan; dePablo Team
2014-11-01
Liquid crystals (LC) posses anisotropic viscoelastic properties, and, as such, LC flow can be incredibly complicated. Here we employ a hybrid lattice Boltzmann method (pioneered by Deniston, Yeomans and Cates) to systematically study the hydrodynamics of nematic liquid crystals (LCs) with and without solid particles. This method evolves the velocity field through lattice Boltzmann and the LC-order parameter via a finite-difference solver of the Beris-Edwards equation. The evolution equation of the boundary points with finite anchoring is obtained through Poisson bracket formulation. Our method has been validated by matching the Ericksen-Leslie theory. We demonstrate two applications in the flow alignment regime. We first investigate a hybrid channel flow in which the top and bottom walls have different anchoring directions. By measuring the apparent shear viscosity in terms of Couette flow, we achieve a viscosity inhomogeneous system which may be applicable to nano particle processing. In the other example, we introduce a homeotropic spherical particle to the channel, and focus on the deformations of the defect ring due to anchorings and flow. The results are then compared to the molecular dynamics simulations of a colloid particle in an LC modeled by a Gay-Berne potential.
Yamane, Naoe; Takami, Tomonori; Tozuka, Zenzaburo; Sugiyama, Yuichi; Yamazaki, Akira; Kumagai, Yuji
2009-01-01
A sample treatment procedure and high-sensitive liquid chromatography/tandem mass spectrometry (LC/MS/MS) method for quantitative determination of nicardipine in human plasma were developed for a microdose clinical trial with nicardipine, a non-radioisotope labeled drug. The calibration curve was linear in the range of 1-500 pg/mL using 1 mL of plasma. Analytical method validation for the clinical dose, for which the calibration curve was linear in the range of 0.2-100 ng/mL using 20 microL of plasma, was also conducted. Each method was successfully applied to making determinations in plasma using LC/MS/MS after administration of a microdose (100 microg) and clinical dose (20 mg) to each of six healthy volunteers. We tested new approaches in the search for metabolites in plasma after microdosing. In vitro metabolites of nicardipine were characterized using linear ion trap-fourier transform ion cyclotron resonance mass spectrometry (LIT-FTICRMS) and the nine metabolites predicted to be in plasma were analyzed using LC/MS/MS. There is a strong possibility that analysis of metabolites by LC/MS/MS may advance to utilization in microdose clinical trials with non-radioisotope labeled drugs.
Seraglio, Siluana Katia Tischer; Valese, Andressa Camargo; Daguer, Heitor; Bergamo, Greici; Azevedo, Mônia Stremel; Gonzaga, Luciano Valdemiro; Fett, Roseane; Costa, Ana Carolina Oliveira
2016-09-01
A simple, reproducible and sensitive method has been optimized and validated for simultaneous determination of 32 phenolic compounds in bracatinga (Mimosa scabrella Benth.) with the diluted-and-shoot approach, without the need of any additional clean-up steps. It has been based on high performance liquid chromatography coupled with triple quadrupole tandem mass spectrometry and electrospray ionization (HPLC-ESI-MS/MS). The chromatography conditions were optimized, and due to the selectivity provided by MRM monitoring, LC separation required only 9min. The developed method was validated on the basis of Eurachem and European Commission Decision 2002/657/EC guidelines. Mean recoveries ranged from 70.4 to 110%. Intra-day and inter-day precision with RSD (relative standard deviations) from 0.14 to 18.9% and 0.34 to 20.0%, respectively were achieved. Limits of detection (LOD) and quantification (LOQ) ranged from 0.03 to 3.20μgL -1 and 0.20-12.8μgL -1 . Finally, the method was applied to samples and 20 phenolic compounds were quantified in all the samples analyzed, representing a contribution to the characterization and quantification of phenolic compounds from bracatinga (M. scabrella Bentham) honeydew honey. Copyright © 2016 Elsevier Ltd. All rights reserved.
Jank, Louise; Martins, Magda Targa; Arsand, Juliana Bazzan; Campos Motta, Tanara Magalhães; Hoff, Rodrigo Barcellos; Barreto, Fabiano; Pizzolato, Tânia Mara
2015-11-01
A fast and simple method for residue analysis of the antibiotics classes of macrolides (erythromycin, azithromycin, tylosin, tilmicosin and spiramycin) and lincosamides (lincomycin and clindamycin) was developed and validated for cattle, swine and chicken muscle and for bovine milk. Sample preparation consists in a liquid-liquid extraction (LLE) with acetonitrile, followed by liquid chromatography-electrospray-tandem mass spectrometry analysis (LC-ESI-MS/MS), without the need of any additional clean-up steps. Chromatographic separation was achieved using a C18 column and a mobile phase composed by acidified acetonitrile and water. The method was fully validated according the criteria of the Commission Decision 2002/657/EC. Validation parameters such as limit of detection, limit of quantification, linearity, accuracy, repeatability, specificity, reproducibility, decision limit (CCα) and detection capability (CCβ) were evaluated. All calculated values met the established criteria. Reproducibility values, expressed as coefficient of variation, were all lower than 19.1%. Recoveries range from 60% to 107%. Limits of detection were from 5 to 25 µg kg(-1).The present method is able to be applied in routine analysis, with adequate time of analysis, low cost and a simple sample preparation protocol. Copyright © 2015. Published by Elsevier B.V.
Validation of a mass spectrometry-based method for milk traces detection in baked food.
Lamberti, Cristina; Cristina, Lamberti; Acquadro, Elena; Elena, Acquadro; Corpillo, Davide; Davide, Corpillo; Giribaldi, Marzia; Marzia, Giribaldi; Decastelli, Lucia; Lucia, Decastelli; Garino, Cristiano; Cristiano, Garino; Arlorio, Marco; Marco, Arlorio; Ricciardi, Carlo; Carlo, Ricciardi; Cavallarin, Laura; Laura, Cavallarin; Giuffrida, Maria Gabriella; Gabriella, Giuffrida Maria
2016-05-15
A simple validated LC-MS/MS-based method was set up to detect milk contamination in bakery products, taking the effects of food processing into account for the evaluation of allergen recovery and quantification. Incurred cookies were prepared at eight levels of milk contamination and were cooked to expose all milk components, including allergenic proteins, to food processing conditions. Remarkable results were obtained in term of sufficiently low LOD and LOQ (1.3 and 4 mg/kg cookies, respectively). Precision was calculated as intra-day repeatability (RSD in the 5-20% range) and inter-day repeatability (4 days; RSD never exceeded 12%). The extraction recovery values ranged from 20% to 26%. Method applicability was evaluated by analysing commercial cookies labelled either as "milk-free" or "may contain milk". Although the ELISA methodology is considered the gold standard for detecting allergens in foods, this robust LC-MS/MS approach should be a useful confirmatory method for assessing and certifying "milk-free" food products. Copyright © 2015 Elsevier Ltd. All rights reserved.
Bae, Jung-Woo; Choi, Chang-Ik; Jang, Choon-Gon; Lee, Seok-Yong
2011-11-01
A simple and sensitive liquid chromatography-electrospray ionization-tandem mass spectrometry (LC-ESI-MS/MS) technique was developed and validated for the determination of sibutramine and its N-desmethyl metabolites (M1 and M2) in human plasma. After extraction with methyl t-butyl ether, chromatographic separation of analytes in human plasma was performed using a reverse-phase Luna C18 column with a mobile phase of acetonitrile-10 mm ammonium formate buffer (50:50, v/v) and quantified by ESI-MS/MS detection in positive ion mode. The flow rate of the mobile phase was 200 μL/min and the retention times of sibutramine, M1, M2 and internal standard (chlorpheniramine) were 1.5, 1.4, 1.3 and 0.9 min, respectively. The calibration curves were linear over the range 0.05-20 ng/mL, for sibutramine, M1 and M2. The lower limit of quantification was 0.05 ng/mL using 500 μL of human plasma. The mean accuracy and the precision in the intra- and inter-day validation for sibutramine, M1 and M2 were acceptable. This LC-MS/MS method showed improved sensitivity and a short run time for the quantification of sibutramine and its two active metabolites in plasma. The validated method was successfully applied to a pharmacokinetic study in human. Copyright © 2011 John Wiley & Sons, Ltd.
Parsons, Teresa L; Emory, Joshua F; Seserko, Lauren A; Aung, Wutyi S; Marzinke, Mark A
2014-09-01
Topical microbicidal agents are being actively pursued as a modality to prevent HIV viral transmission during sexual intercourse. Quantification of antiretroviral agents in specimen sources where antiviral activity is elicited is critical, and drug measurements in cervicovaginal fluid can provide key information on local drug concentrations. Two antiretroviral drugs, dapivirine and maraviroc, have gained interest as vaginal microbicidal agents, and rugged methods are required for their quantification in cervicovaginal secretions. Cervicovaginal fluid spiked with dapivirine and maraviroc were applied to ophthalmic tear strips or polyester-based swabs to mimic collection procedures used in clinical studies. Following sample extraction and the addition of isotopically labeled internal standards, samples were subjected to liquid chromatographic-tandem mass spectrometric (LC-MS/MS) analysis using a Waters BEH C8, 50mm×2.1mm, 1.7μm particle size column, on an API 4000 mass analyzer operated in selective reaction monitoring mode. The method was validated according to FDA Bioanalytical Method Validation guidelines. Due to the disparate saturation capacity of the tested collection devices, the analytical measuring ranges for dapivirine and maravirocin cervicovaginal fluid on the ophthalmic tear strip were 0.05-25ng/tear strip, and 0.025-25ng/tear strip, respectively. As for the polyester-based swab, the analytical measuring ranges were 0.25-125ng/swab for dapivirine and 0.125-125ng/swab for maraviroc. Dilutional studies were performed for both analytes to extended ranges of 25,000ng/tear strip and 11,250ng/swab. Standard curves were generated via weighted (1/x(2)) linear or quadratic regression of calibrators. Precision, accuracy, stability and matrix effects studies were all performed and deemed acceptable according to the recommendations of the FDA Bioanalytical Method Validation guidelines. A rugged LC-MS/MS method for the dual quantification of dapivirine and maraviroc in cervicovaginal fluid using two unique collection devices has been developed and validated. The described method meets the criteria to support large research trials. Copyright © 2014 Elsevier B.V. All rights reserved.
Sun, Hanwen; Wang, Fengchi; Ai, Lianfeng; Guo, Chunhai; Chen, Ruichun
2009-01-01
A sensitive method based on solid-phase extraction-liquid chromatography-tandem mass spectrometry interfaced with electrospray ionization (SPE-LC-MS/MS-ESI) was developed for the simultaneous determination of 8 banned nitroimidazole (NOZ) drugs including metronidazole (MNZ), ronidazole (RNZ), dimetridazole (DMZ), tinidazole, ornidazole, secnidazole, metronidazole-OH (MNZOH, the metabolite of MNZ), and 2-hydroxymethyl-1-methyl-5-nitroimidazole (HMMNI, the metabolite of RNZ and DMZ) in natural casings. After extraction with ethyl acetate and evaporation, the NOZs were reconstituted in ethyl acetate and purified on a strong cation-exchange SPE column, and then LC/MS/MS analysis was performed by positive ESI applying multiple reaction monitoring of 2 transition reactions for each compound. The method was validated according to the European Union requirements (Commission Decision 2002/657/EC). Specificity, linearity, decision limit (CCalpha), detection capability (CCbeta), accuracy, and precision were determined. Average recoveries of the 8 NOZs from natural animal casing fortified at 3 levels (0.1, 0.5, and 1 microg/kg) ranged from 87.3 to 116.5%. The calculated CCalpha for NOZs ranged from 0.029 to 0.049 microg/kg, and CCbeta ranged from 0.049 to 0.083 microg/kg. Repeatability was in the range of 3.35-10.1%, and within-laboratory reproducibility was <10.3%.
Appel, David I.; Brinda, Bryan; Markowitz, John S.; Newcorn, Jeffrey H.; Zhu, Hao-Jie
2012-01-01
A simple, rapid and sensitive method for quantification of atomoxetine by liquid chromatography- tandem mass spectrometry (LC-MS/MS) was developed. This assay represents the first LC-MS/MS quantification method for atomoxetine utilizing electrospray ionization. Deuterated atomoxetine (d3-atomoxetine) was adopted as the internal standard. Direct protein precipitation was utilized for sample preparation. This method was validated for both human plasma and in vitro cellular samples. The lower limit of quantification was 3 ng/ml and 10 nM for human plasma and cellular samples, respectively. The calibration curves were linear within the ranges of 3 ng/ml to 900 ng/ml and 10 nM to 10 μM for human plasma and cellular samples, respectively (r2 > 0.999). The intra- and inter-day assay accuracy and precision were evaluated using quality control samples at 3 different concentrations in both human plasma and cellular lysate. Sample run stability, assay selectivity, matrix effect, and recovery were also successfully demonstrated. The present assay is superior to previously published LC-MS and LC-MS/MS methods in terms of sensitivity or the simplicity of sample preparation. This assay is applicable to the analysis of atomoxetine in both human plasma and in vitro cellular samples. PMID:22275222
Comparison of ESI- and APCI-LC-MS/MS methods: A case study of levonorgestrel in human plasma.
Wang, Rulin; Zhang, Lin; Zhang, Zunjian; Tian, Yuan
2016-12-01
Electrospray ionization (ESI) and atmospheric pressure chemical ionization (APCI) techniques for liquid chromatography-tandem mass spectrometry (LC-MS/MS) determination of levonorgestrel were evaluated. In consideration of difference in ionization mechanism, the two ionization sources were compared in terms of LC conditions, MS parameters and performance of method. The sensitivity for detection of levonorgestrel with ESI was 0.25 ng/mL which was lower than 1 ng/mL with APCI. Matrix effects were evaluated for levonorgestrel and canrenone (internal standard, IS) in human plasma, and the results showed that APCI source appeared to be slightly less liable to matrix effect than ESI source. With an overall consideration, ESI was chosen as a better ionization technique for rapid and sensitive quantification of levonorgestrel. The optimized LC-ESI-MS/MS method was validated for a linear range of 0.25-50 ng/mL with a correlation coefficient ≥0.99. The intra- and inter-batch precision and accuracy were within 11.72% and 6.58%, respectively. The application of this method was demonstrated by a bioequivalence study following a single oral administration of 1.5 mg levonorgestrel tablets in 21 Chinese healthy female volunteers.
Athar Masood, M; Veenstra, Timothy D
2017-08-26
Urine Drug Testing (UDT) is an important analytical/bio-analytical technique that has inevitably become an integral and vital part of a testing program for diagnostic purposes. This manuscript presents a tailor-made LC-MS/MS quantitative assay method development and validation for a custom group of 33 pain panel drugs and their metabolites belonging to different classes (opiates, opioids, benzodiazepines, illicit, amphetamines, etc.) that are prescribed in pain management and depressant therapies. The LC-MS/MS method incorporates two experiments to enhance the sensitivity of the assay and has a run time of about 7 min. with no prior purification of the samples required and a flow rate of 0.7 mL/min. The method also includes the second stage metabolites for some drugs that belong to different classes but have first stage similar metabolic pathways that will enable to correctly identify the right drug or to flag the drug that might be due to specimen tampering. Some real case examples and difficulties in peak picking were provided with some of the analytes in subject samples. Finally, the method was deliberated with some randomly selected de-identified clinical subject samples, and the data evaluated from "direct dilute and shoot analysis" and after "glucuronide hydrolysis" were compared. This method is now used to run routinely more than 100 clinical subjects samples on a daily basis. This article is protected by copyright. All rights reserved. This article is protected by copyright. All rights reserved.
A new LC-MS/MS bioanalytical method for atenolol in human plasma and milk.
Phyo Lwin, Ei Mon; Gerber, Cobus; Song, Yunmei; Leggett, Catherine; Ritchie, Usha; Turner, Sean; Garg, Sanjay
2017-04-01
A new sensitive LC-MS/MS method for the quantification of atenolol in human plasma and milk has been developed for clinical lactation studies. Atenolol and the internal standard, phenazone, were extracted from biological matrices by protein precipitation. A Phenomenex ® C-18 column and gradient chromatographic conditions were used for separation of the analyte, followed by detection with MS. Stability of samples was confirmed for atenolol in human plasma and milk for up to 3 months. Linearity range of 1-800 ng/ml (r 2 = 0.9995), the precision within 15% CV and the recovery of the analyte (80-100% range) were achieved. A new validated analytical method for atenolol in plasma and milk was developed.
NASA Astrophysics Data System (ADS)
Greer, Tyler; Lietz, Christopher B.; Xiang, Feng; Li, Lingjun
2015-01-01
Absolute quantification of protein targets using liquid chromatography-mass spectrometry (LC-MS) is a key component of candidate biomarker validation. One popular method combines multiple reaction monitoring (MRM) using a triple quadrupole instrument with stable isotope-labeled standards (SIS) for absolute quantification (AQUA). LC-MRM AQUA assays are sensitive and specific, but they are also expensive because of the cost of synthesizing stable isotope peptide standards. While the chemical modification approach using mass differential tags for relative and absolute quantification (mTRAQ) represents a more economical approach when quantifying large numbers of peptides, these reagents are costly and still suffer from lower throughput because only two concentration values per peptide can be obtained in a single LC-MS run. Here, we have developed and applied a set of five novel mass difference reagents, isotopic N, N-dimethyl leucine (iDiLeu). These labels contain an amine reactive group, triazine ester, are cost effective because of their synthetic simplicity, and have increased throughput compared with previous LC-MS quantification methods by allowing construction of a four-point standard curve in one run. iDiLeu-labeled peptides show remarkably similar retention time shifts, slightly lower energy thresholds for higher-energy collisional dissociation (HCD) fragmentation, and high quantification accuracy for trypsin-digested protein samples (median errors <15%). By spiking in an iDiLeu-labeled neuropeptide, allatostatin, into mouse urine matrix, two quantification methods are validated. The first uses one labeled peptide as an internal standard to normalize labeled peptide peak areas across runs (<19% error), whereas the second enables standard curve creation and analyte quantification in one run (<8% error).
Baldo, Matías N; Angeli, Emmanuel; Gareis, Natalia C; Hunzicker, Gabriel A; Murguía, Marcelo C; Ortega, Hugo H; Hein, Gustavo J
2018-04-01
A relative bioavailability study (RBA) of two phenytoin (PHT) formulations was conducted in rabbits, in order to compare the results obtained from different matrices (plasma and blood from dried blood spot (DBS) sampling) and different experimental designs (classic and block). The method was developed by liquid chromatography tandem-mass spectrometry (LC-MS/MS) in plasma and blood samples. The different sample preparation techniques, plasma protein precipitation and DBS, were validated according to international requirements. The analytical method was validated with ranges 0.20-50.80 and 0.12-20.32 µg ml -1 , r > 0.999 for plasma and blood, respectively. Accuracy and precision were within acceptance criteria for bioanalytical assay validation (< 15 for bias and CV% and < 20 for limit of quantification (LOQ)). PHT showed long-term stability, both for plasma and blood, and under refrigerated and room temperature conditions. Haematocrit values were measured during the validation process and RBA study. Finally, the pharmacokinetic parameters (C max , T max and AUC 0-t ) obtained from the RBA study were tested. Results were highly comparable for matrices and experimental designs. A matrix correlation higher than 0.975 and a ratio of (PHT blood) = 1.158 (PHT plasma) were obtained. The results obtained herein show that the use of classic experimental design and DBS sampling for animal pharmacokinetic studies should be encouraged as they could help to prevent the use of a large number of animals and also animal euthanasia. Finally, the combination of DBS sampling with LC-MS/MS technology showed to be an excellent tool not only for therapeutic drug monitoring but also for RBA studies.
Boison, Joe O; Asea, Philip A; Matus, Johanna L
2012-08-01
A new and sensitive multi-residue method (MRM) with detection by LC-MS/MS was developed and validated for the screening, determination, and confirmation of residues of 7 nitroimidazoles and 3 of their metabolites in turkey muscle tissues at concentrations ≥ 0.05 ng/g. The compounds were extracted into a solvent with an alkali salt. Sample clean-up and concentration was then done by solid-phase extraction (SPE) and the compounds were quantified by liquid chromatography-tandem mass spectrometry (LC-MS/MS). The characteristic parameters including repeatability, selectivity, ruggedness, stability, level of quantification, and level of confirmation for the new method were determined. Method validation was achieved by independent verification of the parameters measured during method characterization. The seven nitroimidazoles included are metronidazole (MTZ), ronidazole (RNZ), dimetridazole (DMZ), tinidazole (TNZ), ornidazole (ONZ), ipronidazole (IPR), and carnidazole (CNZ). It was discovered during the single laboratory validation of the method that five of the seven nitroimidazoles (i.e. metronidazole, dimetridazole, tinidazole, ornidazole and ipronidazole) and the 3 metabolites (1-(2-hydroxyethyl)-2-hydroxymethyl-5-nitroimidazole (MTZ-OH), 2-hydroxymethyl-1-methyl-5-nitroimidazole (HMMNI, the common metabolite of ronidazole and dimetridazole), and 1-methyl-2-(2'-hydroxyisopropyl)-5-nitroimidazole (IPR-OH) included in this study could be detected, confirmed, and quantified accurately whereas RNZ and CNZ could only be detected and confirmed but not accurately quantified. © Her Majesty the Queen in Right of Canada as Represented by the Minister of Agriculture and Agri-food Canada 2012.
Oliveira, Fabiano Aurélio da Silva; Pereira, Elba Nathália Corrêa; Gobbi, Jennifer Mattedi; Soto-Blanco, Benito; Melo, Marília Martins
2018-01-01
Beef meat is an important food that can be contaminated by pesticides. This study aimed to optimize a multiresidue method for identification and quantification of pesticides in beef meat by liquid chromatography coupled to mass spectrometry detection (LC-MS). The extraction and clean-up procedures were adapted from the QuECHERS method. From the 188 analytes tested, the method was validated as qualitative method for 19 compounds and as quantitative method for 152 compounds. The results were satisfactory, yielding coefficients of variation of less than 20% and recoveries ranging from 70% to 120% and expanded uncertainty of less than 50%. The quantification limit was typically 10 µg kg -1 (but 25 µg kg -1 for 12 of the compounds) and the detection limit was 5.0 µg kg -1 . Thirty-two real samples of commercialized beef meat were analyzed without any residual pesticide being found. Thus, the results showed that the multiresidue method for detecting 171 pesticides, using adapted QuECHERS for extraction and LC-MS for detection, is suitable for analyzing beef meat.
Maier, Barbara; Vogeser, Michael
2013-04-01
Isotope dilution LC-MS/MS methods used in the clinical laboratory typically involve multi-point external calibration in each analytical series. Our aim was to test the hypothesis that determination of target analyte concentrations directly derived from the relation of the target analyte peak area to the peak area of a corresponding stable isotope labelled internal standard compound [direct isotope dilution analysis (DIDA)] may be not inferior to conventional external calibration with respect to accuracy and reproducibility. Quality control samples and human serum pools were analysed in a comparative validation protocol for cortisol as an exemplary analyte by LC-MS/MS. Accuracy and reproducibility were compared between quantification either involving a six-point external calibration function, or a result calculation merely based on peak area ratios of unlabelled and labelled analyte. Both quantification approaches resulted in similar accuracy and reproducibility. For specified analytes, reliable analyte quantification directly derived from the ratio of peak areas of labelled and unlabelled analyte without the need for a time consuming multi-point calibration series is possible. This DIDA approach is of considerable practical importance for the application of LC-MS/MS in the clinical laboratory where short turnaround times often have high priority.
Dillon, Gerald Patrick; Keegan, Jason D; Wallace, Geoff; Yiannikouris, Alexandros; Moran, Colm Anthony
2018-06-01
Docosahexaenoic acid (DHA), is an omega 3 fatty acid (n-3 FA) that has been shown to play a role in canine growth and physiological integrity and improvements in skin and coat condition. However, potential adverse effects of n-3 FA specifically, impaired cellular immunity has been observed in dogs fed diets with elevated levels of n-3 FA. As such, a safe upper limit (SUL) for total n-3 FAs (DHA and EPA) in dogs has been established. Considering this SUL, sensitive methods detecting DHA in blood serum as a biomarker when conducting n-3 FA supplementation trials involving dogs are required. In this study, an LC-ESI-MS/MS method of DHA detection in dog serum was validated and verified. Recovery of DHA was optimized and parallelism tests were conducted with spiked samples demonstrating that the serum matrix did not interfere with quantitation. The stability of DHA in serum was also investigated, with -80 °C considered suitable when storing samples for up to six months. The method was linear over a calibration range of 1-500 μg/mL and precision and accuracy were found to meet the requirements for validation. This method was verified in an alternative laboratory using a different analytical system and operator, with the results meeting the criteria for verification. Copyright © 2018. Published by Elsevier Inc.
Tsuchiya, Megumi; Karim, M Rezaul; Matsumoto, Taro; Ogawa, Hidesato; Taniguchi, Hiroaki
2017-01-24
Transcriptional coregulators are vital to the efficient transcriptional regulation of nuclear chromatin structure. Coregulators play a variety of roles in regulating transcription. These include the direct interaction with transcription factors, the covalent modification of histones and other proteins, and the occasional chromatin conformation alteration. Accordingly, establishing relatively quick methods for identifying proteins that interact within this network is crucial to enhancing our understanding of the underlying regulatory mechanisms. LC-MS/MS-mediated protein binding partner identification is a validated technique used to analyze protein-protein interactions. By immunoprecipitating a previously-identified member of a protein complex with an antibody (occasionally with an antibody for a tagged protein), it is possible to identify its unknown protein interactions via mass spectrometry analysis. Here, we present a method of protein preparation for the LC-MS/MS-mediated high-throughput identification of protein interactions involving nuclear cofactors and their binding partners. This method allows for a better understanding of the transcriptional regulatory mechanisms of the targeted nuclear factors.
Castilhos, Tamara S; Barreto, Fabiano; Meneghini, Leonardo; Bergold, Ana Maria
2016-07-01
A reliable and simple method for the detection and quantification of residues of 14 non-steroidal anti-inflammatory drugs and a metamizole metabolite in swine muscle was developed using liquid chromatography-electrospray ionisation-tandem mass spectrometry (LC-ESI-MS/MS). The samples were extracted with acetonitrile (ACN) in solid-liquid extraction followed by a low-temperature partitioning (LLE-LTP) process at -20 ± 2°C. After evaporation to dryness, the residue was reconstituted with hexane and a mixture of water:acetonitrile (1:1). LC separation was achieved on a reversed-phase (RP18) column with gradient elution using water (phase A) and ACN (phase B) both containing 1 mmol l(-)(1) ammonium acetate (NH4COO) with 0.025% acetic acid. Analysis was carried out on a triple-quadrupole tandem mass spectrometer (LC-MS/MS) in multiple reaction monitoring mode using an electrospray interface in negative and positive mode in a single run. Method validation was performed according to the criteria of Commission Decision No. 2002/657/EC. The matrix effect and linearity were evaluated. Decision limit (CCα), detection capability (CCβ), accuracy and repeatability of the method are also reported. The proposed method proved to be simple, easy and adequate for high-throughput analysis and was applied to routine analysis by the Brazilian Ministry of Agriculture, Livestock and Food Supply.
Sakai, Hiroyuki; Nagao, Hidenori; Sakurai, Mamoru; Okumura, Takako; Nagai, Yoshiyuki; Shikuma, Junpei; Ito, Rokuro; Imazu, Tetsuya; Miwa, Takashi; Odawara, Masato
2015-01-01
For measuring serum 3,3',5'-triiodothyronine (rT3) levels, radioimmunoassay (RIA) has traditionally been used owing to the lack of other reliable methods; however, it has recently become difficult to perform. Meanwhile, liquid chromatography-tandem mass spectrometry (LC-MS/MS) has recently been attracting attention as a novel alternative method in clinical chemistry. To the best of our knowledge, there are no studies to date comparing results of the quantification of human serum rT3 between LC-MS/MS and RIA. We therefore examined the feasibility of LC-MS/MS as a novel alternative method for measuring serum rT3, thyroxine (T4), and 3,5,3'-triiodothyronine (T3) levels. Assay validation was performed by LC-MS/MS using quality control samples of rT3, T4, and T3 at 4 various concentrations which were prepared from reference compounds. Serum samples of 50 outpatients in our department were quantified both by LC-MS/MS and conventional immunoassay for rT3, T4, and T3. Correlation coefficients between the 2 measurement methods were statistically analyzed respectively. Matrix effects were not observed with our method. Intra-day and inter-day precisions were less than 10.8% and 9.6% for each analyte at each quality control level, respectively. Intra-day and inter-day accuracies were between 96.2% and 110%, and between 98.3% and 108.6%, respectively. The lower limit of quantification was 0.05 ng/mL. Strong correlations were observed between the 2 measurement methods (correlation coefficient, T4: 0.976, p < 0.001; T3: 0.912, p < 0.001; rT3: 0.928, p < 0.001). Our LC-MS/MS system requires no manual cleanup operation, and the process after application of a sample is fully automated; furthermore, it was found to be highly sensitive, and superior in both precision and accuracy. The correlation between the 2 methods over a wide range of concentrations was strong. LC-MS/MS is therefore expected to become a useful tool for clinical diagnosis and research.
de Jager, Lowri S; Perfetti, Gracia A; Diachenko, Gregory W
2007-03-23
A LC-MS method was developed for the determination of coumarin, vanillin, and ethyl vanillin in vanilla products. Samples were analyzed using LC-electrospray ionization (ESI)-MS in the positive ionization mode. Limits of detection for the method ranged from 0.051 to 0.073 microg mL(-1). Using the optimized method, 24 vanilla products were analyzed. All samples tested negative for coumarin. Concentrations ranged from 0.38 to 8.59 mg mL(-1) (x =3.73) for vanillin and 0.33 to 2.27 mg mL(-1) (x =1.03) for ethyl vanillin. The measured concentrations are compared to values calculated using UV monitoring and to results reported in a similar survey in 1988. Analytical results, method precision, and accuracy data are presented.
Slimani, Kahina; Pirotais, Yvette; Maris, Pierre; Abjean, Jean-Pierre; Hurtaud-Pessel, Dominique
2018-10-01
A novel and reliable method to quantify residual levels of N-(3-aminopropyl)-N-dodecylpropane-1,3-diamine in dairy products using ion-pairing reversed-phase liquid chromatography-tandem mass spectrometry (LC-MS/MS) was developed and fully validated. Sample extraction was done with salting-out technique using acetonitrile and sodium chloride. For LC-MS/MS, the analyte was detected using positive electrospray ionization (ESI+) and two multiple reaction monitoring (MRM) transitions were monitored. The method was validated in the 5-150 µg kg -1 range using total error approach. Thus, performance criteria of the method were evaluated. Relative standard deviations for trueness and precision were lower than 10%; with the exception of hard pressed cheese at 5 µg kg -1 for precision. The limit of quantification (LOQ) was around 5-7 µg kg -1 depending on the matrix of interest. The method was successfully applied to accurately quantify N-(3-aminopropyl)-N-dodecylpropane-1,3-diamine in 146 various dairy products with a maximum contamination level of 225 µg kg -1 in cheese. Copyright © 2018 Elsevier Ltd. All rights reserved.
BMAA extraction of cyanobacteria samples: which method to choose?
Lage, Sandra; Burian, Alfred; Rasmussen, Ulla; Costa, Pedro Reis; Annadotter, Heléne; Godhe, Anna; Rydberg, Sara
2016-01-01
β-N-Methylamino-L-alanine (BMAA), a neurotoxin reportedly produced by cyanobacteria, diatoms and dinoflagellates, is proposed to be linked to the development of neurological diseases. BMAA has been found in aquatic and terrestrial ecosystems worldwide, both in its phytoplankton producers and in several invertebrate and vertebrate organisms that bioaccumulate it. LC-MS/MS is the most frequently used analytical technique in BMAA research due to its high selectivity, though consensus is lacking as to the best extraction method to apply. This study accordingly surveys the efficiency of three extraction methods regularly used in BMAA research to extract BMAA from cyanobacteria samples. The results obtained provide insights into possible reasons for the BMAA concentration discrepancies in previous publications. In addition and according to the method validation guidelines for analysing cyanotoxins, the TCA protein precipitation method, followed by AQC derivatization and LC-MS/MS analysis, is now validated for extracting protein-bound (after protein hydrolysis) and free BMAA from cyanobacteria matrix. BMAA biological variability was also tested through the extraction of diatom and cyanobacteria species, revealing a high variance in BMAA levels (0.0080-2.5797 μg g(-1) DW).
Application of a new vitamin D blood test on the Emirati population.
Shah, Iltaf; Al-Dabbagh, Bayan; Gariballa, Salah; Al-Menhali, Asma; Muhammad, Neak; Yasin, Javed; Ashraf, S Salman
2018-06-01
Research shows that immunoassay techniques are not the best choice for the estimation of vitamin D in human blood samples. The main reasons are that some immunoassays are not able to distinguish between 25-OHD3 and 25-OHD2 vitamin D metabolites. Furthermore, immunoassays cannot differentiate between 25OHD and inactive epimers of vitamin D. Vitamin D epimers and isobars have been known to overlap with the 25OHD signals and give false positives when tested. Liquid chromatography tandem-mass spectrometry (LC-MS/MS) can differentiate between 25OHD3 and 25OHD2. Separating epimers and isobars (which have the same molecular weight) from vitamin D is achieved through chromatographic separation from actual 25OHD peaks, although this could also cause inaccuracies in vitamin D measurements. The main aim of this study was to develop and validate an improved LC-MS/MS method (using a Shimadzu 8060 system) that could accurately detect and quantitate up to 10 different metabolites of vitamin D, as well as differentiate the epimers and isobars. The secondary aim was to apply the developed LC-MS/MS method for the accurate measurement of blood vitamin D levels in the Emirati population. The Shimadzu 8060 system was run using positive ion electrospray ionization (ESI) in Dynamic Multiple Reaction Monitoring (DMRM) mode for quantification. The method involved blood sample collection from 80 Emirati volunteers, followed by serum extraction and liquid-liquid extraction. The chromatography column used for the analysis was an Ascentis Express F5. Precursor and product ions were detected using a Shimadzu 8060 LC-MS/MS system, and 10 metabolites of vitamin D were detected and quantified, including epimers and isobars. The method validation showed good sensitivity, recovery, linearity, precision, specificity, and accuracy. Furthermore, the data showed that vitamin D epimer 3-epi-25OHD and isobar 7-α-hydroxy-4-cholesten-3-one (7αC4) accounted for a significant portion of vitamin D results in the Emirati population. We report a more reliable, reproducible, and robust LC-MS/MS method for the accurate detection of 25OHD (vitamin D) in the Emirati population. The method has the capacity to detect and separate 10 metabolites of vitamin D as well as separate 25OHD from co-eluting epimers and isobars. The method has also been successfully implemented in gauging vitamin D deficiency in the Emirati population. Thus, this improved LC-MS/MS method could prove very useful in accurately estimating the levels of vitamin D in the Emirati population and in further clinical studies. Copyright © 2018 Elsevier Ltd. All rights reserved.
Liu, Jia; Zhao, Mingming; Zhou, Juntuo; Liu, Changjie; Zheng, Lemin; Yin, Yuxin
2016-11-01
Trimethylamine-N-oxide (TMAO) is a metabolite generated from choline, betaine and carnitine in a gut microbiota-dependent way. This molecule is associated with development of atherosclerosis and cardiovascular events. A sensitive liquid chromatographic electrospray ionization tandem mass spectrometry (LC-ESI-MS/MS) has been developed and validated for the simultaneous determination of TMAO related molecules including TMAO, betaine, choline, and carnitine in mouse plasma. Analytes are extracted after protein precipitation by methanol and subjected to LC-ESI-MS/MS without preliminary derivatization. Separation of analytes was achieved on an amide column with acetonitrile-water as the mobile phase. This method has been fully validated in this study in terms of selectivity, linearity, sensitivity, precision, accuracy, and carryover effect, and the stability of the analyte under various conditions has been confirmed. This developed method has successfully been applied to plasma samples of our mouse model. Copyright © 2016 Elsevier B.V. All rights reserved.
Jorge, Tiago F; Florêncio, Maria H; António, Carla
2017-01-01
Drought is a major limiting factor in agriculture and responsible for dramatic crop yield losses worldwide. The adjustment of the metabolic status via accumulation of drought stress-responsive osmolytes is one of the many strategies that some plants have developed to cope with water deficit conditions. Osmolytes are highly polar compounds, analysis of whcih is difficult with typical reversed-phase chromatography. Porous graphitic carbon (PGC) has shown to be a suitable alternative to reversed-phase stationary phases for the analysis of highly polar compounds typically found in the plant metabolome. In this chapter, we describe the development and validation of a PGC-based liquid chromatography tandem mass spectrometry (LC-MS n ) method suitable for the target analysis of water-soluble carbohydrates, such as raffinose family oligosaccharides (RFOs). We present detailed information regarding PGC column equilibration, LC-MS n system operation, data analysis, and important notes to be considered during the steps of method development and validation.
Song, Yuelin; Song, Qingqing; Li, Jun; Zheng, Jiao; Li, Chun; Zhang, Yuan; Zhang, Lingling; Jiang, Yong; Tu, Pengfei
2016-07-08
Direct analysis is of great importance to understand the real chemical profile of a given sample, notably biological materials, because either chemical degradation or diverse errors and uncertainties might be resulted from sophisticated protocols. In comparison with biofluids, it is still challenging for direct analysis of solid biological samples using high performance liquid chromatography coupled with tandem mass spectrometry (LC-MS/MS). Herein, a new analytical platform was configured by online hyphenating pressurized liquid extraction (PLE), turbulent flow chromatography (TFC), and LC-MS/MS. A facile, but robust PLE module was constructed based on the phenomenon that noticeable back-pressure can be generated during rapid fluid passing through a narrow tube. TFC column that is advantageous at extracting low molecular analytes from rushing fluid was employed to link at the outlet of the PLE module to capture constituents-of-interest. An electronic 6-port/2-position valve was introduced between TFC column and LC-MS/MS to fragment each measurement into extraction and elution phases, whereas LC-MS/MS took the charge of analyte separation and monitoring. As a proof of concept, simultaneous determination of 24 endogenous substances including eighteen steroids, five eicosanoids, and one porphyrin in feces was carried out in this paper. Method validation assays demonstrated the analytical platform to be qualified for directly simultaneous measurement of diverse endogenous analytes in fecal matrices. Application of this integrated platform on homolog-focused profiling of feces is discussed in a companion paper. Copyright © 2016 Elsevier B.V. All rights reserved.
Reagen, William K; Lindstrom, Kent R; Thompson, Kathy L; Flaherty, John M
2004-09-01
The widespread use of semi- and nonvolatile organofluorochemicals in industrial facilities, concern about their persistence, and relatively recent advancements in liquid chromatography/mass spectrometry (LC/MS) technology have led to the development of new analytical methods to assess potential worker exposure to airborne organofluorochemicals. Techniques were evaluated for the determination of 19 organofluorochemicals and for total fluorine in ambient air samples. Due to the potential biphasic nature of most of these fluorochemicals when airborne, Occupational Safety and Health Administration (OSHA) versatile sampler (OVS) tubes were used to simultaneously trap fluorochemical particulates and vapors from workplace air. Analytical methods were developed for OVS air samples to quantitatively analyze for total fluorine using oxygen bomb combustion/ion selective electrode and for 17 organofluorochemicals using LC/MS and gas chromatography/mass spectrometry (GC/MS). The experimental design for this validation was based on the National Institute of Occupational Safety and Health (NIOSH) Guidelines for Air Sampling and Analytical Method Development and Evaluation, with some revisions of the experimental design. The study design incorporated experiments to determine analytical recovery and stability, sampler capacity, the effect of some environmental parameters on recoveries, storage stability, limits of detection, precision, and accuracy. Fluorochemical mixtures were spiked onto each OVS tube over a range of 0.06-6 microg for each of 12 compounds analyzed by LC/MS and 0.3-30 microg for 5 compounds analyzed by GC/MS. These ranges allowed reliable quantitation at 0.001-0.1 mg/m3 in general for LC/MS analytes and 0.005-0.5 mg/m3 for GC/MS analytes when 60 L of air are sampled. The organofluorochemical exposure guideline (EG) is currently 0.1 mg/m3 for many analytes, with one exception being ammonium perfluorooctanoate (EG is 0.01 mg/m3). Total fluorine results may be used to determine if the individual compounds quantified provide a suitable mass balance of total airborne organofluorochemicals based on known fluorine content. Improvements in precision and/or recovery as well as some additional testing would be needed to meet all NIOSH validation criteria. This study provided valuable information about the accuracy of this method for organofluorochemical exposure assessment.
Shaikh, Abdul S; Guo, Ruichen
2017-01-01
Phenytoin has very challenging pharmacokinetic properties. To prevent its toxicity and ensure efficacy, continuous therapeutic monitoring is required. It is hard to get a simple, accurate, rapid, easily available, economical and highly sensitive assay in one method for therapeutic monitoring of phenytoin. The present study is directed towards establishing and validating a simpler, rapid, an accurate, highly sensitive, novel and environment friendly liquid chromatography/mass spectrometry (LC/MS) method for offering rapid and reliable TDM results of phenytoin in epileptic patients to physicians and clinicians for making immediate and rational decision. 27 epileptics patients with uncontrolled seizures or suspected of non-compliance or toxicity of phenytoin were selected and advised for TDM of phenytoin by neurologists of Qilu Hospital Jinan, China. The LC/MS assay was used for performing of therapeutic monitoring of phenytoin. The Agilent 1100 LC/MS system was used for TDM. The mixture of Ammonium acetate 5mM: Methanol at (35: 65 v/v) was used for the composition of mobile phase. The Diamonsil C18 (150mm×4.6mm, 5μm) column was used for the extraction of analytes in plasma. The samples were prepared with one step simple protein precipitation method. The technique was validated with the guidelines of International Conference on Harmonisation (ICH). The calibration curve demonstrated decent linearity within (0.2-20 µg/mL) concentration range with linearity equation, y= 0.0667855 x +0.00241785 and correlation coefficient (R2) of 0.99928. The specificity, recovery, linearity, accuracy, precision and stability results were within the accepted limits. The concentration of 0.2 µg/mL was observed as lower limit of quantitation (LLOQ), which is 12.5 times lower than the currently available enzyme-multiplied immunoassay technique (EMIT) for measurement of phenytoin in epilepsy patients. A rapid, simple, economical, precise, highly sensitive and novel LC/MS assay has been established, validated and applied successfully in TDM of 27 epileptics patients. It was alarmingly found that TDM results of all these patients were out of safe range except two patients. However, it needs further evaluation. Besides TDM, the stated method can also be applied in bioequivalence, pharmacokinetics, toxicokinetics and pharmacovigilance studies. Copyright© Bentham Science Publishers; For any queries, please email at epub@benthamscience.org.
Huang, Fei-Fei; Yang, Qing; Han, Xuan Ye; Zhang, Jing-Ping; Lin, Ting
2017-08-01
The purpose of this study was to develop a Self-Efficacy Scale for Rehabilitation Management designed specifically for postoperative lung cancer patients (SESPRM-LC) and to evaluate its psychometric properties. Based on the concept of self-management of chronic disease, items were developed from literature review and semistructured interviews of 10 lung cancer patients and screened by expert consultation and pilot testing. Psychometric evaluation was done with 448 postoperative lung cancer patients recruited from 5 tertiary hospitals in Fuzhou, China, by incorporating classical test theory and item response theory methods. A 6-factor structure was illustrated by exploratory factor analysis and confirmed by confirmatory factor analysis, explaining 60.753% of the total variance. The SESPRM-LC achieved Cronbach's α of 0.694 to 0.893, 2-week test-retest reliability of 0.652 to 0.893, and marginal reliability of 0.565 to 0.934. The predictive and criterion validities were demonstrated by significant association with theoretically supported quality-of-life variables (r = 0.211-0.392, P < .01), and General Perceived Self-efficacy Scale (r = 0.465, P < .01), respectively. Item response theory analysis showed that the SESPRM-LC offers information about a broad range of self-efficacy measures and discriminates well between patients with high and low levels of self-efficacy. We demonstrated initial support for the reliability and validity of the 27-item SESPRM-LC, as a developmentally appropriate instrument for assessing self-efficacy among lung cancer patients during postoperative rehabilitation. Copyright © 2016 John Wiley & Sons, Ltd.
Illamola, S M; Labat, L; Benaboud, S; Tubiana, R; Warszawski, J; Tréluyer, J M; Hirt, D
2014-08-15
Lopinavir is an HIV protease inhibitor with high protein binding (98-99%) in human plasma. This study was designed to develop an ultrafiltration method to measure the unbound concentrations of lopinavir overcoming the non-specific binding issue. A liquid chromatography-tandem mass spectrometry (LC-MS/MS) method for the determination of total concentrations of lopinavir in plasma was developed and validated, and an adaptation was also optimized and validated for the determination of unbound concentrations. The chromatographic separation was performed with a C18 column (100 mm × 2.1mm i.d., 5 μm particle size) using a mobile phase containing deionized water with formic acid, and acetonitrile, with gradient elution at a flow-rate of 350 μL min(-1). Identification of the compounds was performed by multiple reaction monitoring, using electrospray ionization in positive ion mode. The method was validated over a clinical range of 0.01-1 μg/mL for human plasma ultrafiltrate and 0.1-15 μg/mL in human plasma. The inter and intra-assay accuracies and precisions were between 0.23% and 11.37% for total lopinavir concentrations, and between 3.50% and 13.30% for plasma ultrafiltrate (unbound concentration). The ultrafiltration method described allows an accurate separation of the unbound fraction of lopinavir, circumscribing the loss of drug by nonspecific binding (NSB), and the validated LC-MS/MS methodology proposed is suitable for the determination of total and unbound concentrations of lopinavir in clinical practice. Copyright © 2014 Elsevier B.V. All rights reserved.
Determination of benzoylurea insecticides in food by pressurized liquid extraction and LC-MS.
Brutti, Monia; Blasco, Cristina; Picó, Yolanda
2010-01-01
A method based on pressurized liquid extraction and LC-MS/MS has been developed for determining nine benzoylureas (BUs) in fruit, vegetable, cereals, and animal products. Samples (5 g) were homogenized with diatomaceous earth and extracted in a 22 mL cell with 22 mL of ethyl acetate at 80 degrees C and 1500 psi. After solvent concentration and exchange to methanol, BUs were analyzed by LC-MS/MS using an IT mass analyzer, which achieved several transitions of precursor ions that increase selectivity providing identification. LOQs were between 0.002 and 0.01 mg/kg, which are equal or lower than maximum residue limits established by the Codex Alimentarius. Excellent linearity was achieved over a range of concentrations from 0.01 to 1 mg/kg with correlation coefficients 0.995-0.999 (n=7). Validation of the total method was performed by analyzing in quintuplicate seven different commodities (milk, eggs, meat, rice, lettuce, avocado, and lemon) at three concentration levels (0.01, 0.1, and 1 mg/kg). The recoveries ranged from 58 to 97% and the RSDs from 5 to 19% depending on the compound and the commodity. The combination of pressurized liquid extraction with LC-MS/MS provides a sensitive and selective method for the determination of BUs in food.
Guale, Fessessework; Shahreza, Shahriar; Walterscheid, Jeffrey P; Chen, Hsin-Hung; Arndt, Crystal; Kelly, Anna T; Mozayani, Ashraf
2013-01-01
Liquid chromatography time-of-flight mass spectrometry (LC-TOF-MS) analysis provides an expansive technique for identifying many known and unknown analytes. This study developed a screening method that utilizes automated solid-phase extraction to purify a wide array of analytes involving stimulants, benzodiazepines, opiates, muscle relaxants, hypnotics, antihistamines, antidepressants and newer synthetic "Spice/K2" cannabinoids and cathinone "bath salt" designer drugs. The extract was applied to LC-TOF-MS analysis, implementing a 13 min chromatography gradient with mobile phases of ammonium formate and methanol using positive mode electrospray. Several common drugs and metabolites can share the same mass and chemical formula among unrelated compounds, but they are structurally different. In this method, the LC-TOF-MS was able to resolve many isobaric compounds by accurate mass correlation within 15 ppm mass units and a narrow retention time interval of less than 10 s of separation. Drug recovery yields varied among spiked compounds, but resulted in overall robust area counts to deliver an average match score of 86 when compared to the retention time and mass of authentic standards. In summary, this method represents a rapid, enhanced screen for blood and urine specimens in postmortem, driving under the influence, and drug facilitated sexual assault forensic toxicology casework.
Abushareeda, Wadha; Vonaparti, Ariadni; Saad, Khadija Al; Almansoori, Moneera; Meloug, Mbarka; Saleh, Amal; Aguilera, Rodrigo; Angelis, Yiannis; Horvatovich, Peter L; Lommen, Arjen; Alsayrafi, Mohammed; Georgakopoulos, Costas
2018-03-20
The aim of this paper is to present the development and validation of a high-resolution full scan (HR-FS) electrospray ionization (ESI) liquid chromatography coupled to quadrupole Orbitrap mass spectrometer (LC/Q/Orbitrap MS) platform for the screening of prohibited substances in human urine according to World Antidoping Agency (WADA) requirements. The method was also validated for quantitative analysis of six endogenous steroids (epitestosterone, testosterone, 5α-dihydrotestosterone, dehydroepiandrosterone, androsterone and etiocholanolone) in their intact sulfates form. The sample preparation comprised a combination of a hydrolyzed urine liquid-liquid extraction and the dilute & shoot addition of original urine in the extracted aliquot. The HR-FS MS acquisition mode with Polarity Switching was applied in combination of the Quadrupole-Orbitrap mass filter. The HR-FS acquisition of analytical signal, for known and unknown small molecules, allows the inclusion of all analytes detectable with LC-MS for antidoping investigations to identify the use of known or novel prohibited substances and metabolites after electronic data files' reprocessing. The method has been validated to be fit-for-purpose for the antidoping analysis. Copyright © 2017 Elsevier B.V. All rights reserved.
Ouyang, Hui; Guo, Yicheng; He, Mingzhen; Zhang, Jinlian; Huang, Xiaofang; Zhou, Xin; Jiang, Hongliang; Feng, Yulin; Yang, Shilin
2015-03-01
A simple, sensitive and specific liquid chromatography-tandem mass spectrometry method was developed and validated for the determination of Pulsatilla saponin D, a potential antitumor constituent isolated from Pulsatilla chinensis in rat plasma. Rat plasma samples were pretreated by protein precipitation with methanol. The method validation was performed in accordance with US Food and Drug Administration guidelines and the results met the acceptance criteria. The method was successfully applied to assess the pharmacokinetics and oral bioavailability of Pulsatilla saponin D in rats. Copyright © 2014 John Wiley & Sons, Ltd.
Quantifying MMA by SLE LC-MS/MS: Unexpected challenges in assay development.
Lo, Sheng-Ying; Gordon, Cindy; Sadilkova, Katerina; Jack, Rhona M; Dickerson, Jane A
2016-09-01
Analysis of serum/plasma methylmalonic acid (MMA) is important for the diagnosis and management of methylmalonic acidemia in pediatric populations. This work focuses on developing and validating a liquid chromatography tandem mass spectrometry (LC-MS/MS) method to monitor methylmalonic acidemia using a simple method preparation. MMA and stable isotope labeled d3-MMA was extracted using supported liquid extraction (SLE). Assay imprecision, bias, linearity, recovery and carryover were determined. The relationship between MMA and propionyl acylcarnitine (C3-acylcarnitine) was also evaluated using historical paired results from 51 unique individuals. Baseline separation between MMA and succinic acid was completed in 7min. The assay was linear from 0.1 to 500μM. The intra-day and inter-day imprecision CV ranged from 4.1 to 13.2% (0.3 to 526μM) and 5.0 to 15.7% (0.3 to 233μM), respectively. Recovery ranged from 93 to 125%. The correlation with a national reference laboratory LC-MS/MS assay showed a Deming regression of 1.026 and intercept of -1.335. Carryover was determined to be <0.04%. Patient-specific correlation was observed between MMA and C3-acylcarnitine. This report describes the first LC-MS/MS method using SLE for MMA extraction. In addition, we illustrate the challenges encountered during this method development that should be assessed and resolved by any laboratory implementing a SLE LC-MS/MS assay designed to quantify analytes across several orders of magnitude. Copyright © 2016 The Canadian Society of Clinical Chemists. Published by Elsevier Inc. All rights reserved.
Gajbhiye, Narendra A; Makasana, Jayanti; Kumar, Satyanshu
2015-01-01
A comprehensive experiment was conducted to study the accumulation pattern and determination of three important bioactive compounds namely withaferin-A (WA), 12-deoxywithastramonolide (WO) and withanolide-A (WD) and its determination by the liquid chromatography/electrospray ionization tandem mass spectrometry (LC-ESI-MS-MS) method in root, stem, fruits and leaves of Withania somnifera. A rapid and sensitive LC-ESI-MS-MS method was developed and validated for the determination of these three important bioactive compounds, having same molecular weight. The multiple reaction monitoring method was established by two transitions for each analyte and intense transition used for quantification. Separation of the three analytes was achieved within a run time of 5 min on an RP-18 column using a mobile phase consisting of acetonitrile and 0.1% acetic acid in water in an isocratic condition. The developed method was validated as per the ICH guidelines. The developed method was found to be suitable for identification and quantification of WA, WO and WD in different plant parts such as roots, stems, fruits and leaves of W. somnifera. The accumulation of WA was highest in leaves samples (8.84 ± 0.37 mg/g) and it was 2.23, 5.85 and 27.26 times higher than its concentration in fruits, stems and roots, respectively. WO and WD contents were highest (0.44 ± 0.016 and 0.72 ± 0.016 mg/g, respectively) in root. © The Author 2015. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.
Camino-Sánchez, F J; Zafra-Gómez, A; Oliver-Rodríguez, B; Ballesteros, O; Navalón, A; Crovetto, G; Vílchez, J L
2010-11-01
A rapid, simple and sensitive multi-residue method was developed and validated for the simultaneous quantification and confirmation of 69 pesticides in fruit and vegetables using liquid chromatography-tandem mass spectrometry (LC-MS/MS). The samples were extracted following the quick, easy, cheap, effective, rugged and safe method known as QuEChERS. Mass spectrometric conditions were individually optimised for each analyte in order to achieve maximum sensitivity in multiple reaction monitoring (MRM) mode. Using the developed chromatographic conditions, 69 pesticides can be separated in less than 17 min. Two selected reaction monitoring (SRM) assays were used for each pesticide to obtain simultaneous quantification and identification in one run. With this method in SRM mode, more than 150 pesticides can be analysed and quantified, but their confirmation is not possible in all cases according to the European regulations on pesticide residues. Nine common representative matrices (zucchini, melon, cucumber, watermelon, tomato, garlic, eggplant, lettuce and pepper) were selected to investigate the effect of different matrices on recovery and precision. Mean recoveries ranged from 70% to 120%, with relative standard deviations (RSDs) lower than 20% for all the pesticides. The proposed method was applied to the analysis of more than 2000 vegetable samples from the extensive greenhouse cultivation in the province of Almeria, Spain, during one year. The methodology combines the advantages of both QuEChERS and LC-MS/MS producing a very rapid, sensitive, accurate and reliable procedure that can be applied in routine analytical laboratories. The method was validated and accredited according to UNE-EN-ISO/IEC 17025:2005 international standard (accreditation number 278/LE1027).
NASA Astrophysics Data System (ADS)
Stefanović, S.; Đorđevic, V.; Jelušić, V.
2017-09-01
The aim of this paper is to verify the performance characteristics and fitness for purpose of rapid and simple QuEChERS-based LC-MS/MS method for determination of acrylamide in potato chips and coffee. LC-MS/MS is by far the most suitable analytical technique for acrylamide measurements given its inherent sensitivity and selectivity, as well as capability of analyzing underivatized molecule. Acrylamide in roasted coffee and potato chips wasextracted with water:acetonitrile mixture using NaCl and MgSO4. Cleanup was carried out with MgSO4 and PSA. Obtained results were satisfactory. Recoveries were in the range of 85-112%, interlaboratory reproducibility (Cv) was 5.8-7.6% and linearity (R2) was in the range of 0.995-0.999. LoQ was 35 μg kg-1 for coffee and 20 μg kg-1 for potato chips. Performance characteristic of the method are compliant with criteria for analytical methods validation. Presented method for quantitative determination of acrylamide in roasted coffee and potato chips is fit for purposes of self-control in food industry as well as regulatory controls carried out by the governmental agencies.
Simões, Rodrigo Almeida; Bonato, Pierina Sueli; Mirnaghi, Fatemeh S; Bojko, Barbara; Pawliszyn, Janusz
2015-01-01
A high-throughput bioanalytical method using 96-blade thin film microextraction (TFME) and LC-MS/MS for the analysis of repaglinide (RPG) and two of its main metabolites was developed and used for an in vitro metabolism study. The target analytes were extracted from human microsomal medium by a 96-blade-TFME system employing the low-cost prototype 'SPME multi-sampler' using C18 coating. Method validation showed recoveries around 90% for all analytes and was linear over the concentration range of 2-1000 ng ml(-1) for RPG and of 2-500 ng ml(-1) for each RPG metabolite. The method was applied to an in vitro metabolism study of RPG employing human liver microsomes and proved to be very useful for this purpose.
Ewles, Matthew; Mannu, Ranbir; Fox, Chris; Stanta, Johannes; Evans, Graeme; Goodwin, Lee; Duffy, James; Bell, Len; Estdale, Sian; Firth, David
2016-12-01
We aimed to establish novel, high-throughput LC-MS/MS strategies for quantification of monoclonal antibodies in human serum and examine the potential impact of antidrug antibodies. We present two strategies using a thermally stable immobilized trypsin. The first strategy uses whole serum digestion and the second introduces Protein G enrichment to improve the selectivity. The impact of anti-trastuzumab antibodies on the methods was tested. Whole serum digestion has been validated for trastuzumab (LLOQ 0.25 µg/ml). Protein G enrichment has been validated for trastuzumab (LLOQ 0.1 µg/ml), bevacizumab (LLOQ 0.1 µg/ml) and adalimumab (LLOQ 0.25 µg/ml). We have shown the potential for anti-drug antibodies to impact on the quantification and we have subsequently established a strategy to overcome this impact where total quantification is desired.
Breindahl, Torben; Evans-Brown, Michael; Hindersson, Peter; McVeigh, Jim; Bellis, Mark; Stensballe, Allan; Kimergård, Andreas
2015-02-01
New methods were developed and validated to determine the identity, contents, and purity of samples of melanotan II, a synthetic melanocortin receptor agonist, sold in vials as injectable skin-tanning products that were purchased from three online shops. Methods were based on liquid chromatography with ultra-violet detection (LC-UV) at wavelength 218 nm, and tandem mass spectrometric detection (MS/MS) after collision-induced fragmentation of the double charged [M+2H](2+) precursor ion (m/z 513). Identification of melanotan II was verified by correct chromatographic retention time, and relative abundance ratios of five qualifying fragment ions. LC-UV was used to quantify melanotan II as well as impurities. Method validation was performed with reference to guidelines for assessing active substances in authorized medicinal products to reach acceptable accuracy and precision. Vials from two shops contained unknown impurities ranging from 4.1 to 5.9%; impurities from one shop were below the quantification limit. The total amount of melanotan II in vials ranged between 4.32 and 8.84 mg, although each shop claimed that vials contained 10 mg melanotan II. A broad range of drugs used for enhancement purposes can be obtained from the illicit market. However, users of these drugs may be exposed to a range of potential harms, as shown in this study, given that these products are manufactured, distributed and supplied from an illicit market. Copyright © 2014 John Wiley & Sons, Ltd.
McCleary, Barry V; DeVries, Jonathan W; Rader, Jeanne I; Cohen, Gerald; Prosky, Leon; Mugford, David C; Champ, Martine; Okuma, Kazuhiro
2010-01-01
A method for the determination of total dietary fiber (TDF), as defined by the CODEX Alimentarius, was validated in foods. Based upon the principles of AOAC Official Methods 985.29, 991.43, 2001.03, and 2002.02, the method quantitates high- and low-molecular-weight dietary fiber (HMWDF and LMWDF, respectively). In 2007, McCleary described a method of extended enzymatic digestion at 37 degrees C to simulate human intestinal digestion followed by gravimetric isolation and quantitation of HMWDF and the use of LC to quantitate low-molecular-weight soluble dietary fiber (LMWSDF). The method thus quantitates the complete range of dietary fiber components from resistant starch (by utilizing the digestion conditions of AOAC Method 2002.02) to digestion resistant oligosaccharides (by incorporating the deionization and LC procedures of AOAC Method 2001.03). The method was evaluated through an AOAC collaborative study. Eighteen laboratories participated with 16 laboratories returning valid assay data for 16 test portions (eight blind duplicates) consisting of samples with a range of traditional dietary fiber, resistant starch, and nondigestible oligosaccharides. The dietary fiber content of the eight test pairs ranged from 11.57 to 47.83%. Digestion of samples under the conditions of AOAC Method 2002.02 followed by the isolation and gravimetric procedures of AOAC Methods 985.29 and 991.43 results in quantitation of HMWDF. The filtrate from the quantitation of HMWDF is concentrated, deionized, concentrated again, and analyzed by LC to determine the LMWSDF, i.e., all nondigestible oligosaccharides of degree of polymerization > or =3. TDF is calculated as the sum of HMWDF and LMWSDF. Repeatability standard deviations (Sr) ranged from 0.41 to 1.43, and reproducibility standard deviations (S(R)) ranged from 1.18 to 5.44. These results are comparable to other official dietary fiber methods, and the method is recommended for adoption as Official First Action.
Jardim, Andréia Nunes Oliveira; Mello, Denise Carvalho; Goes, Fernanda Caroline Silva; Frota Junior, Elcio Ferreira; Caldas, Eloisa Dutra
2014-12-01
A multiresidue method for the determination of 46 pesticides in fruits was validated. Samples were extracted with acidified ethyl acetate, MgSO4 and CH3COONa and cleaned up by dispersive SPE with PSA. The compounds were analysed by GC-FPD, GC-μECD or LC-MS/MS, with LOQs from 1 to 8 μg/kg. The method was used to analyse 238 kaki, cashew apple, guava, and peach fruit and pulp samples, which were also analysed for dithiocarbamates (DTCs) using a spectrophotometric method. Over 70% of the samples were positive, with DTC present in 46.5%, λ-cyhalothrin in 37.1%, and omethoate in 21.8% of the positive samples. GC-MS/MS confirmed the identities of the compounds detected by GC. None of the pesticides found in kaki, cashew apple and guava was authorised for these crops in Brazil. The risk assessment has shown that the cumulative acute intake of organophosphorus or pyrethroid compounds from the consumption of these fruits is unlikely to pose a health risk to consumers. Copyright © 2014 Elsevier Ltd. All rights reserved.
Mochizuki, Ayumi; Ieki, Katsunori; Kamimori, Hiroshi; Nagao, Akemi; Nakai, Keiko; Nakayama, Akira; Nanba, Eitaro
2018-04-01
The guidance and several guidelines on bioanalytical method validation, which were issued by the US FDA, EMA and Ministry of Health, Labour and Welfare, list the 'full' validation parameters; however, none of these provide any details for 'partial' validation. Japan Bioanalysis Forum approved a total of three annual discussion groups from 2012 to 2014. In the discussion groups, members from pharmaceutical companies and contract research organizations discussed the details of partial validation from a risk assessment viewpoint based on surveys focusing on bioanalysis of small molecules using LC-MS/MS in Japan. This manuscript presents perspectives and recommendations for most conceivable changes that can be made to full and partial validations by members of the discussion groups based on their experiences and discussions at the Japan Bioanalysis Forum Symposium.
Assessment of data pre-processing methods for LC-MS/MS-based metabolomics of uterine cervix cancer.
Chen, Yanhua; Xu, Jing; Zhang, Ruiping; Shen, Guoqing; Song, Yongmei; Sun, Jianghao; He, Jiuming; Zhan, Qimin; Abliz, Zeper
2013-05-07
A metabolomics strategy based on rapid resolution liquid chromatography/tandem mass spectrometry (RRLC-MS/MS) and multivariate statistics has been implemented to identify potential biomarkers in uterine cervix cancer. Due to the importance of the data pre-processing method, three popular software packages have been compared. Then they have been used to acquire respective data matrices from the same LC-MS/MS data. Multivariate statistics was subsequently used to identify significantly changed biomarkers for uterine cervix cancer from the resulting data matrices. The reliabilities of the identified discriminated metabolites have been further validated on the basis of manually extracted data and ROC curves. Nine potential biomarkers have been identified as having a close relationship with uterine cervix cancer. Considering these in combination as a biomarker group, the AUC amounted to 0.997, with a sensitivity of 92.9% and a specificity of 95.6%. The prediction accuracy was 96.6%. Among these potential biomarkers, the amounts of four purine derivatives were greatly decreased, which might be related to a P2 receptor that might lead to a decrease in cell number through apoptosis. Moreover, only two of them were identified simultaneously by all of the pre-processing tools. The results have demonstrated that the data pre-processing method could seriously bias the metabolomics results. Therefore, application of two or more data pre-processing methods would reveal a more comprehensive set of potential biomarkers in non-targeted metabolomics, before a further validation with LC-MS/MS based targeted metabolomics in MRM mode could be conducted.
Cho, Doo-Yeoun; Bae, Soo Hyeon; Shon, Ji-Hong; Bae, Soo Kyung
2013-03-01
A high-sensitivity LC/MS/MS method was developed and validated for the simultaneous determination of mirodenafil and its major metabolite, SK-3541, in human plasma. Mirodenafil, SK-3541, and udenafil as an internal standard were extracted from plasma samples with methyl tert-butyl ether. Chromatographic separation was performed on a Luna phenyl-hexyl column (100 × 2.0 mm) with an isocratic mobile phase consisting of 5 mM ammonium formate and ACN (23:77, v/v) at a flow rate of 0.35 mL/min. Detection and quantification were performed using a mass spectrometer in selected reaction monitoring mode with positive ESI at m/z 532.3 → 296.1 for mirodenafil, m/z 488.1 → 296.1 for SK-3541, and m/z 517.3 → 283.2 for udenafil. The calibration curves were linear over a concentration range of 2-500 pg/mL using 0.5 mL plasma for the microdose of mirodenafil (100 μg). Analytical method validation of the clinical dose (100 mg), with a calibration curve range of 2-500 ng/mL using 0.025-mL plasma, was also conducted. The other LC-MS/MS conditions were similar to those used for the microdosing. Each method was applied successfully to pharmacokinetic studies after a microdose or clinical dose of mirodenafil to six healthy Korean male volunteers. © 2013 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.
Satoh, Mamoru; Ishige, Takayuki; Ogawa, Shoujiro; Nishimura, Motoi; Matsushita, Kazuyuki; Higashi, Tatsuya; Nomura, Fumio
2016-11-01
The quantification of serum 25-hydroxyvitamin D [25(OH)D] as an indicator of vitamin D status is currently primarily conducted by immunoassays, yet LC-MS/MS would allow more accurate determination. Furthermore, LC-MS/MS would allow simultaneous measurement of multiple analytes. The aim of this study was to develop and validate an LC-MS/MS method to simultaneously measure four vitamin D metabolites (25(OH)D 3 , 3-epi-25(OH)D 3 , 25(OH)D 2 , and 24,25(OH) 2 D 3 ) in serum for clinical laboratory applications. Serum samples were first prepared in a 96-well supported liquid extraction plate and the eluate was derivatized using the Cookson-type reagent 4-(4'-dimethylaminophenyl)-1,2,4-triazoline-3,5-dione (DAPTAD), which rapidly and quantitatively reacts with the s-cis-diene structure of vitamin D metabolites. The derivatized samples were subjected to LC-MS/MS, ionized by electrospray ionization (positive-ion mode), and detected by selected reaction monitoring. The lower limits of quantification for 25(OH)D 3 , 3-epi-25(OH)D 3 , 25(OH)D 2 , and 24,25(OH) 2 D 3 were 0.091, 0.020, 0.013, and 0.024 ng/mL, respectively. The accuracy values and the extraction recoveries for these four metabolites were satisfactory. Serum 25(OH)D levels determined by our LC-MS/MS were compared with those obtained by conventional radioimmunoassay (RIA) that cannot distinguish 25(OH)D 3 and 25(OH)D 2 . The values obtained by the RIA method exhibited a mean bias of about 8.35 ng/mL, most likely as a result of cross reaction of the antibody with low-abundance metabolites, including 24,25(OH) 2 D 3 . Various preanalytical factors, such as long sample sitting prior to serum separation, repeated freeze-thaw cycles, and the presence of anticoagulants, had no significant effects on these determinations. This high-throughput LC-MS/MS simultaneous assay of the four vitamin D metabolites 25(OH)D 3 , 3-epi-25(OH)D 3 , 25(OH)D 2 , and 24,25(OH) 2 D 3 required as little as 20 μL serum. This method will aid further understanding of low-abundance vitamin D metabolites, as well as the accurate determination of 25(OH)D 3 and 25(OH)D 2 .
USDA-ARS?s Scientific Manuscript database
A multiresidue analytical method using a modification of the “quick, easy, cheap, effective, rugged, and safe” (QuEChERS) sample preparation approach combined with liquid chromatography–tandem mass spectrometry (LC-MS/MS) analysis was established and validated for the rapid determination of 69 pesti...
Stephanson, N N; Signell, P; Helander, A; Beck, O
2017-08-01
The influx of new psychoactive substances (NPS) has created a need for improved methods for drug testing in toxicology laboratories. The aim of this work was to design, validate and apply a multi-analyte liquid chromatography-high-resolution mass spectrometry (LC-HRMS) method for screening of 148 target analytes belonging to the NPS class, plant alkaloids and new psychoactive therapeutic drugs. The analytical method used a fivefold dilution of urine with nine deuterated internal standards and injection of 2 μl. The LC system involved a 2.0 μm 100 × 2.0 mm YMC-UltraHT Hydrosphere-C 18 column and gradient elution with a flow rate of 0.5 ml/min and a total analysis time of 6.0 min. Solvent A consisted of 10 mmol/l ammonium formate and 0.005% formic acid, pH 4.8, and Solvent B was methanol with 10 mmol/l ammonium formate and 0.005% formic acid. The HRMS (Q Exactive, Thermo Scientific) used a heated electrospray interface and was operated in positive mode with 70 000 resolution. The scan range was 100-650 Da, and data for extracted ion chromatograms used ± 10 ppm tolerance. Product ion monitoring was applied for confirmation analysis and for some selected analytes also for screening. Method validation demonstrated limited influence from urine matrix, linear response within the measuring range (typically 0.1-1.0 μg/ml) and acceptable imprecision in quantification (CV <15%). A few analytes were found to be unstable in urine upon storage. The method was successfully applied for routine drug testing of 17 936 unknown samples, of which 2715 (15%) contained 52 of the 148 analytes. It is concluded that the method design based on simple dilution of urine and using LC-HRMS in extracted ion chromatogram mode may offer an analytical system for urine drug testing that fulfils the requirement of a 'black box' solution and can replace immunochemical screening applied on autoanalyzers. Copyright © 2017 John Wiley & Sons, Ltd. Copyright © 2017 John Wiley & Sons, Ltd.
Schofield, Ryan C.; Ramanathan, Lakshmi V.; Murata, Kazunori; Grace, Marie; Fleisher, Martin; Pessin, Melissa S.; Carlow, Dean C.
2016-01-01
A rapid and simple turbulent flow liquid chromatography (TFC–LC) method implementing positive heated electrospray ionization (HESI) for the accurate and precise determination of methotrexate (MTX), 7-hydroxy methotrexate (7-OH MTX), and 4-amino-4-deoxy-N10-methylpteroic acid (DAMPA) concentrations in serum was developed. MTX was isolated from serum samples (100 μL) after protein precipitation with methanol containing formic acid and internal standard (MTX-D3) followed by centrifugation. The supernatant was injected into the turbulent flow liquid chromatography which is followed by electrospray positive ionization tandem mass spectrometry (TFC–LC–MS/MS) and quantified using a six-point calibration curve. For MTX and DAMPA the assays were linear from 10 to 1000 nmol/L and for 7-OH MTX from 20 to 2000 nmol/L. Dilutions of 10, 100 and 1000-fold were validated giving a clinically reportable range of 10 nmol/L to 5 × 105 nmol/L. Within-day and between-day precisions at concentrations spanning the analytical measurement ranges were less than 10% for all three analytes. MTX, DAMPA and 7-OH MTX were sufficiently stable under all relevant analytical conditions. No significant matrix effect was observed during the method validation. The TFC–LC-MS/MS MTX method was also compared with three other clinically validated MTX assays: a dihydrofolate reductase (DHFR) inhibition assay, an immunoassay based on fluorescence polarization and a previously developed LC–MS/MS assay. PMID:26322588
Goswami, Dipanjan; Kumar, Ajay; Khuroo, Arshad H; Monif, Tausif; Rab, Shamsur
2009-11-01
A LC-MS/MS method for plasma topiramate analysis is delineated involving least number of healthy volunteers. Topiramate and amlodipine internal standard (IS) were extracted by simple centrifuge-coupled solid-phase extraction and reverse-phase chromatographic separation was performed on an Ascentis C(18) column. Turbo-spray negative-ion mode multiple-reaction monitoring was selected for mass pair detection at m/z 338.3 --> 78.0 and m/z 407.3 --> 295.5 for analyte and IS respectively. The method showed a dynamic linearity range from 10.4 to 2045.0 ng/mL, lower limit of quantitation achieved at 10.4 ng/mL and finally a mass spectrometric total run time of within 2.5 min for human sample analysis. Bioequivalence was assessed successfully using this fully validated method on 16 fasted Indian male subjects with 25 mg topiramate tablet administration. An appropriate study design describes plasma samples collection up to 216 h post dose in two periods, separated by a 28 day washout period. The challenge of half-life matching for test and reference drug was achieved with 73.43 +/- 9.68 and 73.06 +/- 14.03 h, respectively, and intra-subject coefficient of variation achieved within 11% for AUCs and C(max) evaluated by non-compartmental pharmacokinetic analysis. The results of LCMS topiramate complete method validation supported by pharmacokinetic study have not been published before, and are presented and discussed for the first time in this article. Copyright (c) 2009 John Wiley & Sons, Ltd.
Simultaneous quantitative analysis of nine vitamin D compounds in human blood using LC-MS/MS.
Abu Kassim, Nur Sofiah; Gomes, Fabio P; Shaw, Paul Nicholas; Hewavitharana, Amitha K
2016-01-01
It has been suggested that each member of the family of vitamin D compounds may have different function(s). Therefore, selective quantification of each compound is important in clinical research. Development and validation attempts of a simultaneous determination method of 12 vitamin D compounds in human blood using precolumn derivatization followed by LC-MS/MS is described. Internal standard calibration with 12 stable isotope labeled analogs was used to correct for matrix effects in MS detector. Nine vitamin D compounds were quantifiable in blood samples with detection limits within femtomole levels. Serum (compared with plasma) was found to be a more suitable sample type, and protein precipitation (compared with saponification) a more effective extraction method for vitamin D assay.
A novel approach for quantitation of glucosylceramide in human dried blood spot using LC-MS/MS.
Ji, Allena Ji; Wang, Haixing; Ziso-Qejvanaj, Enida; Zheng, Kefei; Chung, Lee Lee; Foley, Timothy; Chuang, Wei-Lien; Richards, Susan; Sung, Crystal
2015-01-01
Glucosylceramide, an efficacy biomarker for Gaucher Type 1 disease, exhibits poor solubility in polar solvents and whole blood which makes it difficult to prepare a homogenous blood standard. We developed a novel method using standard addition approach by spiking a small volume of analyte solution on the surface of prespotted dried blood spot. The whole spots were punched out for subsequent extraction and LC-MS/MS analysis. The assay performance met all validation acceptance criteria. Glucosylceramide concentrations in 50 paired plasma and dry blood spot samples obtained from Gaucher Type 1 patients were tested and the results demonstrated the feasibility of using the DBS method for clinical biomarker monitoring. The new approach greatly improves assay precision and accuracy.
Korse, Catharina M; Buning-Kager, Johanna C G M; Linders, Theodora C; Heijboer, Annemieke C; van den Broek, Daan; Tesselaar, Margot E T; van Tellingen, Olaf; van Rossum, Huub H
2017-06-01
Serotonin is used for the diagnosis and follow-up of neuroendocrine tumors (NET). We describe the analytical and clinical validation of a liquid chromatography tandem mass spectrometry (LC-MS/MS) based serotonin assay for serum and platelet-rich plasma (PRP). An LC-MS/MS based method for serum and PRP serotonin was validated by determination of assay imprecision, carry-over, linearity, interference, recovery, sample stability and a matrix/method comparison of serum and PRP serotonin was made with whole blood serotonin. Furthermore, upper limits of normal were determined and serotonin concentrations of healthy individuals, 14 NET patients without evidence of disease and 51 NET patients with evidence of disease were compared. For serum and PRP fractions, total assay imprecision was <5%. All correlation coefficients were 0.98 and the serum and platelet-rich serotonin upper limit of normal were 5.5nmol/10 9 platelet and 5.1nmol/10 9 platelet, respectively. NET patients with confirmed evidence of disease had significantly higher serum and PRP serotonin levels when compared to NET patients without evidence of disease and healthy volunteers. LC-MS/MS based serum and PRP serotonin assays were developed with suitable analytical characteristics. Furthermore, serum and PRP serotonin was found to be useful for monitoring NET patients. Copyright © 2017 Elsevier B.V. All rights reserved.
Suassuna, Fernanda Clotilde Mariz; Maia, Ana Marly Araújo; Melo, Daniela Pita; Antonino, Antônio Celso Dantas; Gomes, Anderson Stevens Leônidas; Bento, Patrícia Meira
2018-02-01
To comparein vitro differences in the apical filling regarding working length (WL) change and presence of voids and to validate optical coherence tomography (OCT) in comparison with computerized microtomography (µCT) for the detection of failures in the apical filling. Forty-five uniradicular teeth with round canals, divided into groups (n = 15) following the obturation protocols: LC (lateral condensation), TMC (thermomechanical compaction) and SC (single cone). Samples were scanned using µCT (parameters: 80 kV, 222 µA, and resolution of 11 µm), OCT (parameters: SSOCT, 1300 nm and axial resolution of 12 µm), and periapical digital radiography. The images were analyzsed by two blind and calibrated observers using ImageJ software to measure the boundary of the obturation WL and voids presence. Categorical and metric data were submitted to inferential analysis, and the validity of the OCT as a diagnostic test was assessed with performance and reliability tests. The WL average remained constant for all obturation techniques and image methods. OCT showed adequate sensitivity and specificity to detect voids in the WL of apical obturations in vitro in comparison with µCT. Both image methods found a higher number of voids for LC technique (µCT p = 0.011/OCT p = 0.002). OCT can be used in apical obturation voids assessment and the LC technique revealed more voids with larger dimensions.
Christiaens, B; Chiap, P; Rbeida, O; Cello, D; Crommen, J; Hubert, Ph
2003-09-25
A new fully automated method for the quantitative analysis of an antiandrogenic substance, cyproterone acetate (CPA), in plasma samples has been developed using on-line solid-phase extraction (SPE) prior to the determination by reversed-phase liquid chromatography (LC). The automated method was based on the use of a precolumn packed with an internal-surface reversed-phase packing material (LiChrospher RP-4 ADS) for sample clean-up coupled to LC analysis on an octadecyl stationary phase using a column-switching system. A 200-microL volume of plasma sample was injected directly on the precolumn packed with restricted access material using a mixture of water-acetonitrile (90:10, v/v) as washing liquid. The analyte was then eluted in the back-flush mode with the LC mobile phase which consisted of a mixture of phosphate buffer, pH 7.0-acetonitrile (54:46, v/v). The elution profiles of CPA and blank plasma samples on the precolumn and the time needed for analyte transfer from the precolumn to the analytical column were determined. Different compositions of washing liquid and mobile phase were tested to reduce the interference of plasma endogenous components. UV detection was achieved at 280 nm. Finally, the developed method was validated using a new approach, namely the application of the accuracy profile based on the interval confidence at 90% of the total measurement error (bias+standard deviation). The limit of quantification of cyproterone acetate in plasma was determined at 15 ng mL(-1). The validated method should be applicable to the determination of CPA in patients treated by at least 50 mg day(-1).
Swortwood, Madeleine J; Boland, Diane M; DeCaprio, Anthony P
2013-02-01
Recently, clandestine drug lab operators have attempted to bypass controlled substances laws and regulations with "designer" compounds chemically and pharmacologically similar to controlled substances. For example, "bath salts" have erupted onto the scene as "legal highs" containing cathinone analogs that have produced severe side effects in users worldwide. These products have sparked concern among law enforcement agencies, and emergency bans have been placed on the sale of such items. Despite the increasing number of designer drugs available, there are few comprehensive screening techniques for their detection and quantification in biological specimens. The liquid chromatography triple quadrupole tandem mass spectrometry (LC-QQQ-MS/MS) method presented here encompasses over thirty important compounds within the phenethylamine, tryptamine, and piperazine designer drug classes. Analytes were determined by LC-QQQ-MS/MS in the multiple-reaction monitoring mode after mixed-mode solid-phase extraction. The bioanalytical method was fully validated according to recommended international guidelines. The assay was selective for all analytes with acceptable accuracy and precision. Limits of quantification were in the range of 1-10 ng/mL for each compound with limits of detection near 10 pg/mL. In order to evaluate its applicability in a forensic toxicological setting, the validated method was used to analyze post-mortem specimens from two cases that were suspected of containing designer drugs. The method was able to identify and quantify seven of these compounds at concentrations as low as 11 ng/mL. The method should have wide applicability for rapid screening of important new drugs of abuse at high sensitivity in both post- and ante-mortem forensic analysis.
Quantification of CSF cystatin C using liquid chromatography tandem mass spectrometry.
Matsuda, Chikashi; Shiota, Yuri; Sheikh, Abdullah Md; Okazaki, Ryota; Yamada, Kazuo; Yano, Shozo; Minohata, Toshikazu; Matsumoto, Ken-Ichi; Yamaguchi, Shuhei; Nagai, Atsushi
2018-03-01
Cystatin C (CST3), a ubiquitously expressed cysteine protease inhibitor, is implicated in several neurological diseases. Here, we have developed an accurate CST3 measurement system based on liquid chromatography tandem mass spectrometry (LC-MS/MS). LC-MS/MS based measurement for CSF CST3 was validated by determination of assay precision, accuracy and recovery. The values were compared with those measured by immunoassay. Glycosylation of CST3 in CSF was analyzed by Western blotting and lectin blotting. Measuring standard CST3 by LC-MS/MS produced a linear standard curve that correlated with assigned values (r 2 =0.99). Both intra- and inter-assay variation was <10%. Although showed a correlation, the average CST3 concentration measured by LC-MS/MS was significantly higher than that of immunoassay. Western blotting showed the presence of a 25KDa species along with CST3 monomer (14KDa) in CSF. The volume of 25KDa species was decreased by deglycosylation. Lectin blotting revealed a 25KDa glycosylated protein in sialidase-treated CSF, which was decreased by deglycosylation. However, deglycosylation did not alter CST3 concentration measured by immunoassay. Our results suggest that LC-MS/MS-based CST3 measurement is a robust method with higher detection ability. Such method could be useful for the diagnosis and monitoring of neurological diseases. Copyright © 2017 Elsevier B.V. All rights reserved.
Machonis, Philip R; Jones, Matthew A; Kwik-Uribe, Catherine
2014-01-01
Recently, a multilaboratory validation (MLV) of AOAC Official Method 2012.24 for the determination of cocoa flavanols and procyanidins (CF-CP) in cocoa-based ingredients and products determined that the method was robust, reliable, and transferrable. Due to the complexity of the CF-CP molecules, this method required a run time exceeding 1 h to achieve acceptable separations. To address this issue, a rapid resolution normal phase LC method was developed, and a single-laboratory validation (SLV) study conducted. Flavanols and procyanidins with a degree of polymerization (DP) up to 10 were eluted in 15 min using a binary gradient applied to a diol stationary phase, detected using fluorescence detection, and reported as a total sum of DP 1-10. Quantification was achieved using (-)-epicatechin-based relative response factors for DP 2-10. Spike recovery samples and seven different types of cocoa-based samples were analyzed to evaluate the accuracy, precision, LOD, LOQ, and linearity of the method. The within-day precision of the reported content for the samples was 1.15-5.08%, and overall precision was 3.97-13.61%. Spike-recovery experiments demonstrated recoveries of over 98%. The results of this SLV were compared to those previously obtained in the MLV and found to be consistent. The translation to rapid resolution LC allowed for an 80% reduction in analysis time and solvent usage, while retaining the accuracy and reliability of the original method. The savings in both cost and time of this rapid method make it well-suited for routine laboratory use.
Challenges for Detecting Valproic Acid in a Nontargeted Urine Drug Screening Method.
Pope, Jeffrey D; Black, Marion J; Drummer, Olaf H; Schneider, Hans G
2017-08-01
Valproic acid (VPA) is a widely prescribed medicine, and acute toxicity is possible. As such, it should be included in any nontargeted urine drug screening method. In many published liquid chromatography-electrospray ionization-mass spectrometry (LC-ESI-MS/MS) methods, VPA is usually measured using a pseudo-multiple reaction monitoring (MRM) transition. We investigate a simple ultra-high-performance liquid chromatography-quadrupole time-of-flight (QTof) approach to detect the presence of VPA with more confidence. Three commercially sourced VPA metabolites were characterized and added to a nontargeted high-resolution MS urine drug screening method. All analyses were performed on a Waters Xevo G2-XS LC-QTof in negative electrospray ionization mode. The mass detector was operated in MS mode, and data were processed with UNIFI software. Sixty-eight patient urine samples, which were previously identified by a well-established gas chromatography-MS method as containing VPA, were analyzed on the Waters Xevo G2-XS LC-QTof, to validate this approach. VPA metabolite standards were characterized, and their detection data were added to the broad drug screening library. VPA metabolites were readily detectable in the urine of patients taking VPA. The inclusion of characterized VPA metabolites provides a simple and reliable method enabling the detection of VPA in nontargeted urine drug screening.
Kaymak, Tugrul; Türker, Levent; Tulay, Hüseyin; Stroka, Joerg
2018-04-27
Background : Pekmez and pestil are traditional Turkish foods made from concentrated grapejuice, which can be contaminated with mycotoxins such as aflatoxins and ochratoxin A (OTA). Objective : To carry out a single-laboratory validation of a method to simultaneously determine aflatoxins B 1 , B₂, G 1 , and G₂ and ochratoxin A in pekmez and pestil. Methods : The homogenized sample is extracted with methanol-water (80 + 20) using a high-speed blender. The (sample) extract is filtered, diluted with phosphate-buffered saline solution, and applied to a multi-immunoaffinity column (AFLAOCHRA PREP®). Aflatoxins and ochratoxin A are removed with (neat) methanol and then directly analyzed by reversed-phase LC with fluorescence detection using post-column bromination (Kobra cell®). Results : Test portions of blank pekmez and pestil were spiked with a mixture of aflatoxins and ochratoxin A to give levels ranging from 2.6 to 10.4 μg/kg and 1.0-4.0 μg/kg, respectively. Recoveries for total aflatoxins and ochratoxin A ranged from 84 to 106% and 80-97%, respectively, for spiked samples. Based on results for spiked pekmez and pestil (30 replicates each at three levels), the repeatability RSD ranged from 1.6 to 12% and 2.7-11% for total aflatoxins and ochratoxin A, respectively. Conclusions : The method performance in terms of recovery, repeatability, and detection limits has been demonstrated to be suitable for use as an Official Method. Highlights : First immunoaffinity column method validated for simultaneous analysis of aflatoxins and ochratoxin A in pekmez and pestil. Suitability for use for official purposes in Turkey, demonstrated by single-laboratory validation. Co-occurrence of aflatoxins and OTA in mulberry and carob pekmez reported for the first time.
Kakiyama, Genta; Muto, Akina; Takei, Hajime; Nittono, Hiroshi; Murai, Tsuyoshi; Kurosawa, Takao; Hofmann, Alan F.; Pandak, William M.; Bajaj, Jasmohan S.
2014-01-01
We have developed a simple and accurate HPLC method for measurement of fecal bile acids using phenacyl derivatives of unconjugated bile acids, and applied it to the measurement of fecal bile acids in cirrhotic patients. The HPLC method has the following steps: 1) lyophilization of the stool sample; 2) reconstitution in buffer and enzymatic deconjugation using cholylglycine hydrolase/sulfatase; 3) incubation with 0.1 N NaOH in 50% isopropanol at 60°C to hydrolyze esterified bile acids; 4) extraction of bile acids from particulate material using 0.1 N NaOH; 5) isolation of deconjugated bile acids by solid phase extraction; 6) formation of phenacyl esters by derivatization using phenacyl bromide; and 7) HPLC separation measuring eluted peaks at 254 nm. The method was validated by showing that results obtained by HPLC agreed with those obtained by LC-MS/MS and GC-MS. We then applied the method to measuring total fecal bile acid (concentration) and bile acid profile in samples from 38 patients with cirrhosis (17 early, 21 advanced) and 10 healthy subjects. Bile acid concentrations were significantly lower in patients with advanced cirrhosis, suggesting impaired bile acid synthesis. PMID:24627129
Dhanure, Shivanand; Savalia, Atulkumar; More, Pravinkumar; Shirode, Prashant; Kapse, Kailas; Shah, Virag
2014-01-01
A simple, sensitive, and selective LC-MS/MS method was developed and validated for the quantification of carbocisteine in human plasma. Rosiglitazone was used as the internal standard and heparin was used as the anticoagulant. The chromatographic separation was performed by using the Waters Symmetry Shield RP 8, 150 × 3.9 mm, 5 μ column at 40°C with a mobile phase consisting of a mixture of methanol and 0.5% formic acid solution in a 40:60 proportion. The flow rate was 500 μl/min along with a 5 μl injection volume. Protein precipitation was used as the extraction method. Mass spectrometric data were detected in positive ion mode. The MRM mode of the ions for carbocisteine was 180.0 > 89.0 and for rosiglitazone it was 238.1 > 135.1. The method was validated in the concentration curve range of 50.000 ng/mL to 6000.000 ng/mL. The retention times of carbocisteine and the internal standard rosiglitazone were approximately 2.20 and 3.01 min, respectively. The overall run time was 4.50 min. This method was found suitable to analyze human plasma samples for the application in pharmacokinetic and BA/BE studies.
Multiplexed LC-MS/MS analysis of horse plasma proteins to study doping in sport.
Barton, Chris; Beck, Paul; Kay, Richard; Teale, Phil; Roberts, Jane
2009-06-01
The development of protein biomarkers for the indirect detection of doping in horse is a potential solution to doping threats such as gene and protein doping. A method for biomarker candidate discovery in horse plasma is presented using targeted analysis of proteotypic peptides from horse proteins. These peptides were first identified in a novel list of the abundant proteins in horse plasma. To monitor these peptides, an LC-MS/MS method using multiple reaction monitoring was developed to study the quantity of 49 proteins in horse plasma in a single run. The method was optimised and validated, and then applied to a population of race-horses to study protein variance within a population. The method was finally applied to longitudinal time courses of horse plasma collected after administration of an anabolic steroid to demonstrate utility for hypothesis-driven discovery of doping biomarker candidates.
Kaale, Eliangiringa; Van Schepdael, Ann; Roets, Eugène; Hoogmartens, Jos
2002-11-07
A reversed-phase liquid chromatography (LC) method has been developed, optimised and validated for the separation and quantitation of capsaicin (CP) and dihydrocapsaicin (DHCP) in a topical cream formulation. Sample preparation involves liquid-liquid extraction prior to LC analysis. The method uses a Hypersil C(18) BDS, 5 micrometer, 250x4.6 mm I.D. column maintained at 35 degrees C. The mobile phase comprises methanol, water, acetonitrile (ACN) and acetic acid (47:42:10:1, v/v/v/v) at a flow rate of 1.0 ml/min. Robustness was evaluated by performing a central composite face-centred design (CCF) experiment. The method shows good selectivity, linearity, sensitivity and repeatability. The conditions allow the separation and quantitation of CP and DHCP without interference from the other substances contained in the cream.
Quantitation of Tenofovir and Emtricitabine in Dried Blood Spots (DBS) with LC-MS/MS
Zheng, Jia-Hua; Guida, Louis A; Rower, Caitlin; Castillo-Mancilla, Jose; Meditz, Amie; Klein, Brandon; Kerr, Becky Jo; Langness, Jacob; Bushman, Lane; Kiser, Jennifer; Anderson, Peter L.
2013-01-01
A reversed-phase high performance liquid chromatographic (LC), tandem mass spectrometry (MS/MS) assay for the determination of tenofovir (TFV) and emtricitabine (FTC) in dried blood spots (DBS) from human whole blood was developed and validated. Whole blood samples were spotted, dried, and a 3mm punch was extracted with methanol for analysis by LC-MS/MS utilizing stable isotope labeled internal standards. The assay was validated over the range of 2.5ng/mL to 1,000ng/mL for TFV and 2.5ng/mL to 5,000ng/mL for FTC. The method was accurate (within ± 15% of control) and precise (coefficient of variation ≤ 15%) for hematocrit concentrations ranging from 25% to 76%; using edge punches versus center punches; and spot volumes of 10µL to 50µL. Analytes were stable for five freeze/thaw cycles and up to 6 days at room temperature, whereas long-term storage required −20°C or −80°C. Comparison of TFV and FTC in DBS versus plasma yielded r2 ≥ 0.96, indicating that DBS can be used as a plasma alternative for pharmacokinetic analyses in vivo. PMID:24055850
LC-MS/MS assay for the quantitation of the tyrosine kinase inhibitor neratinib in human plasma.
Kiesel, Brian F; Parise, Robert A; Wong, Alvin; Keyvanjah, Kiana; Jacobs, Samuel; Beumer, Jan H
2017-02-05
Neratinib is an orally available tyrosine kinase inhibitor targeting HER2 (ERBB2) and EGFR (ERBB). It is being clinically evaluated for the treatment of breast and other solid tumors types as a single agent or in combination with other chemotherapies. In support of several phase I/II clinical trials investigating neratinib combinations, we developed and validated a novel LC-MS/MS assay for the quantification of neratinib in 100μL of human plasma with a stable isotopic internal standard. Analytes were extracted from plasma using protein precipitation and evaporation of the resulting supernatant followed by resuspension. Chromatographic separation was achieved using an Acquity UPLC BEH Shield RP18 column and a gradient methanol-water mobile phase containing 10% ammonium acetate. An ABI 4000 mass spectrometer and electrospray positive mode ionization were used for detection. The assay was linear from 2 to 1,000ng/mL and proved to be accurate (98.9-106.5%) and precise (<6.2%CV), and met the FDA guidance for bioanalytical method validation. This LC-MS/MS assay will be an essential tool to further define the pharmacokinetics of neratinib. Copyright © 2016 Elsevier B.V. All rights reserved.
Ramadan, Gouda; Al Jabir, Muna; Alabdulmalik, Najat; Mohammed, Ali
2016-05-01
Most countries have clearly defined regulations governing the use of pesticides in agricultural activity. The application of pesticides in agriculture usually leads to a residual amount of these pesticides on food products such as fruit and vegetables. The presence of pesticide residues on these foods destined for human consumption may pose food safety risks to consumers. To protect consumers, national authorities have established maximum limits for pesticide residues in foods. These limits can only be enforced if there are methods available to detect and monitor their concentrations in the applicable food products. To support the enforcement of this legislation, we have developed a multi-residue liquid chromatography-tandem mass spectrometry (LC-MS/MS) method for the analysis of 120 pesticide residues in apples and cucumbers which has been validated and implemented in the routine monitoring and surveillance programme for these pesticides. In this method, apple and cucumber samples are extracted using the QuEChERS method (quick, easy, cheap, effective, rugged, and safe) and the extracts were analyzed directly by LC-MS/MS. The mean recoveries at three different concentrations of 0.01 µg/g , 0.05 µg/g, and 0.1 µg/g over the analytical range varied between 70 and 120%. The repeatability of the method expressed as %RSD was less than 20%. The limit of detection (LOD) of the method ranged between 0.0014 and 0.0110 µg/g for apples and between 0.0012 and 0.0075 µg/g for cucumbers. The limit of quantification (LOQ) of the method was 0.01 µg/g for apples and cucumbers. The method has been used for the analysis of over 600 apple and 550 cucumber samples over the past two years. Copyright © 2016 John Wiley & Sons, Ltd. Copyright © 2016 John Wiley & Sons, Ltd.
Kotnala, A; Senthilkumari, S; Halder, N; Kumar, A; Velpandian, T
2018-01-15
To develop a microwave assisted method for the rapid synthesis of A2E and also to develop a method to quantify N-retinylidene-N-retinylethanolamine(A2E), all-trans retinal dimer (ATRD), A2-glycerophospho ethanolamine (A2GPE), dihydropyridine phosphatidyl ethanolamine (A2DHPE) and monofuran A2E (MFA2E) in age matched retina. The development of microwave assisted synthesis of A2E, its purification and characterization for its utility in quantification in human retina. The semi-quantitative method development using LC-ESI-MS, LC-ESI-MS/MS and LC-APCI-MS/MS from pooled macula and peripheral retina for the bisretinoid analysis has been done. Maximum A2E conversion using microwave assisted process took place at 80°C for 45min with a yield of 55.01%. Highly sensitive and specific mass spectrometric method was developed using reverse phase C-18 separation with positive electrospray ionization and positive atmospheric phase chemical ionization of tandom mass spectrometry. A gradient mobile phase separation was achieved using water and methanol with 0.1% TFA. Multiple reaction monitoring acquisition for ESI and APCI was performed at ATRD m/z 551.2/522.2, A2GPE m/z 746.4/729.5, A2DHPEm/z 594.4/576.5, MFA2E m/z 608.2/591.2, A2E m/z 592.4/418.2. Method was validated using LC-ESI-SIM mode to determine selectivity, linearity, sensitivity, precision and accuracy. An attempt towards optimization of the synthetic procedure of A2E was made so as to reduce the lengthy reaction time without compromising the yield. Developed method was capable enough for the detection of low level of bisretinids in retina. Copyright © 2017 Elsevier B.V. All rights reserved.
Rota, Cristina; Cristoni, Simone; Trenti, Tommaso; Cariani, Elisabetta
2013-01-01
Oxidative attack to DNA is of particular interest since DNA modifications can lead to heritable mutations. The most studied product of DNA oxidation is 8-oxo-7,8-dihydro-2′-deoxyguanosine (8-oxodG). While 8-oxodG determination in blood and tissue cells is prone to artifacts, its measurement in urine employing liquid chromatography tandem mass spectrometry (LC-MS/MS) has gained more and more interest for increased reliability. LC-MS/MS can be affected by matrix effects and this is particularly true when ion trap is used as MS analyzer, due to ion accumulation in the trap and related space charge effect. In the present work, we have developed a LC-MS/MS method where the combination of cation exchange and reverse phase solid phases resulted in LC separation optimization. This together with the employment of an isotopically labeled internal standard, allowed the usage of ion trap LC-MS/MS, typically not employed for quantitative measurement in biological samples, for the measurement of 8-oxodG in urine samples from control populations. Four different urine matrices were employed for method validation. Limit of quantitation was set at least at 0.5 ng/ml. While analyzing urine samples from healthy volunteers, 8-oxodG levels reported as ng/ml were statistically different comparing males with females (p<0.05, Mann Whitney test); while comparing results normalized for creatinine no statistical significant difference was found. Mean urinary 8-oxodG level found in healthy volunteers was 1.16±0.46 nmol/mmol creatinine. The present method by enhancing at best the chromatographic performances allows the usage of ion trap LC-MS/MS for the measurement of 8-oxodG in urine samples from control populations. PMID:24251117
Godin, Jean-Philippe; Breuillé, Denis; Obled, Christiane; Papet, Isabelle; Schierbeek, Henk; Hopfgartner, Gérard; Fay, Laurent-Bernard
2008-10-01
On-line gas chromatography-combustion-isotope ratio mass spectrometry (GC-C-IRMS) is commonly used to measure isotopic ratios at natural abundance as well as for tracer studies in nutritional and medical research. However, high-precision (13)C isotopic enrichment can also be measured by liquid chromatography-isotope ratio mass spectrometry (LC-IRMS). Indeed, LC-IRMS can be used, as shown by the new method reported here, to obtain a baseline separation and to measure (13)C isotopic enrichment of underivatised amino acids (Asp, Thr-Ser, Glu, Pro, Gly, Ala, Cys and Val). In case of Val, at natural abundance, the SD(delta(13)C) reported with this method was found to be below 1 per thousand . Another key feature of the new LC-IRMS method reported in this paper is the comparison of the LC-IRMS approach with the conventional GC-C-IRMS determination. To perform this comparative study, isotopic enrichments were measured from underivatised Val and its N(O, S)-ethoxycarbonyl ethyl ester derivative. Between 0.0 and 1.0 molar percent excess (MPE) (delta(13)C= -12.3 to 150.8 per thousand), the calculated root-mean-square (rms) of SD was 0.38 and 0.46 per thousand and the calculated rms of accuracy was 0.023 and 0.005 MPE, respectively, for GC-C-IRMS and LC-IRMS. Both systems measured accurately low isotopic enrichments (0.002 atom percent excess (APE)) with an SD (APE) of 0.0004. To correlate the relative (delta(13)C) and absolute (atom%, APE and MPE) isotopic enrichment of Val measured by the GC-C-IRMS and LC-IRMS devices, mathematical equations showing the slope and intercept of the curves were established and validated with experimental data between 0.0 to 2.3 MPE. Finally, both GC-C-IRMS and LC-IRMS instruments were also used to assess isotopic enrichment of protein-bound (13)C-Val in tibial epiphysis in a tracer study performed in rats. Isotopic enrichments measured by LC-IRMS and GC-C-IRMS were not statistically different (p>0.05). The results of this work indicate that the LC-IRMS was successful for high-precision (13)C isotopic measurements in tracer studies giving (13)C isotopic enrichment similar to the GC-C-IRMS but without the step of GC derivatisation. Therefore, for clinical studies requiring high-precision isotopic measurement, the LC-IRMS is the method of choice to measure the isotopic ratio.
Famiglini, Giorgio; Termopoli, Veronica; Palma, Pierangela; Capriotti, Fabiana; Cappiello, Achille
2014-05-01
An LC-MS method for the analysis of personal care and household products without sample preparation is presented. The method takes advantage of the Direct-electron ionization (EI) LC-MS interface for the quantitation of principal components, as well as for the identification of unknown or undeclared ingredients. The technique has proven its inertness toward matrix effects and the electron ionization allows quantitation and library identification. Commercially available products (shower gel, perfume, and hand cream) were diluted with methanol and injected directly into a nano-LC column. Limonene, linalool, and citral were selected as target compounds because of their use as fragrances in toiletry and detergent products. These and all other fragrances are commonly determined with GC-MS analysis, prior to sample cleanup, a procedure that can lead to analytes loss. The selected compounds are not detected with ESI because of their poor or very low response. Figures of merit and validation studies were executed and special attention was devoted to matrix-effects evaluation, because a sample preparation procedure is not involved. No matrix effects were observed, and the repeatability was excellent even after several weeks of operation. Products composition was investigated in full scan mode to determine the presence of unknown or not listed ingredients. © 2013 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.
Suhr, Anna Catharina; Vogeser, Michael; Grimm, Stefanie H
2016-05-30
For quotable quantitative analysis of endogenous analytes in complex biological samples by isotope dilution LC-MS/MS, the creation of appropriate calibrators is a challenge, since analyte-free authentic material is in general not available. Thus, surrogate matrices are often used to prepare calibrators and controls. However, currently employed validation protocols do not include specific experiments to verify the suitability of a surrogate matrix calibration for quantification of authentic matrix samples. The aim of the study was the development of a novel validation experiment to test whether surrogate matrix based calibrators enable correct quantification of authentic matrix samples. The key element of the novel validation experiment is the inversion of nonlabelled analytes and their stable isotope labelled (SIL) counterparts in respect to their functions, i.e. SIL compound is the analyte and nonlabelled substance is employed as internal standard. As a consequence, both surrogate and authentic matrix are analyte-free regarding SIL analytes, which allows a comparison of both matrices. We called this approach Isotope Inversion Experiment. As figure of merit we defined the accuracy of inverse quality controls in authentic matrix quantified by means of a surrogate matrix calibration curve. As a proof-of-concept application a LC-MS/MS assay addressing six corticosteroids (cortisol, cortisone, corticosterone, 11-deoxycortisol, 11-deoxycorticosterone, and 17-OH-progesterone) was chosen. The integration of the Isotope Inversion Experiment in the validation protocol for the steroid assay was successfully realized. The accuracy results of the inverse quality controls were all in all very satisfying. As a consequence the suitability of a surrogate matrix calibration for quantification of the targeted steroids in human serum as authentic matrix could be successfully demonstrated. The Isotope Inversion Experiment fills a gap in the validation process for LC-MS/MS assays quantifying endogenous analytes. We consider it a valuable and convenient tool to evaluate the correct quantification of authentic matrix samples based on a calibration curve in surrogate matrix. Copyright © 2016 Elsevier B.V. All rights reserved.
Zuben, E S Von; Oliveira, A G; Chorilli, M; Scarpa, M V
2018-03-05
A reversed-phase liquid chromatography (RP-LC) method was successfully developed and validated for the determination of methotrexate in nanostructured liquid crystalline systems composed by polyether functional siloxane and silicone polyether copolymer. The LC method was performed on RP C18-ODS column, Agilent Zorbax® (4.6 x 250 mm, 5 μm), maintained at room temperature, with a mobile phase constituted by a mixture of 50 mM ammonium acetate buffer (pH 6.0) and methanol (77:23,v/v) with a flow rate of 1.0 mL/min, using ultraviolet detection at 313 nm. The parameters used in the validation process were linearity, specificity, intra and inter-day precision, accuracy, robustness. The quantitation and detection limits yielded good results. The calibration plot assumed linear behavior from 5.0-150.0 μg. mL-1 (r2 = 0.9999). The methotrexate was subjected to oxidation, acid, base and neutral degradation, photolysis and heat as stress conditions. There were no interfering peaks at or near the retention time of methotrexate. The nanostructured liquid crystalline systems did not interfere with the analysis and the recovery was quantitative. The intra and inter-day assay relative standard deviation were less than 0.20 %. The method developed proved to be simple, sensitive, accurate, precise, reproducible and therefore adequate for routine analysis of methotrexate in nanostructured liquid crystalline systems.
Honda, Akira; Yamashita, Kouwa; Ikegami, Tadashi; Hara, Takashi; Miyazaki, Teruo; Hirayama, Takeshi; Numazawa, Mitsuteru; Matsuzaki, Yasushi
2009-01-01
We describe a new sensitive and specific method for the quantification of serum malonate (malonic acid, MA), which could be a new biomarker for de novo lipogenesis (fatty acid synthesis). This method is based upon a stable isotope-dilution technique using LC-MS/MS. MA from 50 μl of serum was derivatized into di-(1-methyl-3-piperidinyl)malonate (DMP-MA) and quantified by LC-MS/MS using the positive electrospray ionization mode. The detection limit of the DMP-MA was approximately 4.8 fmol (500 fg) (signal-to-noise ratio = 10), which was more than 100 times more sensitive compared with that of MA by LC-MS/MS using the negative electrospray ionization mode. The relative standard deviations between sample preparations and measurements made using the present method were 4.4% and 3.2%, respectively, by one-way ANOVA. Recovery experiments were performed using 50 μl aliquots of normal human serum spiked with 9.6 pmol (1 ng) to 28.8 pmol (3 ng) of MA and were validated by orthogonal regression analysis. The results showed that the estimated amount within a 95% confidence limit was 14.1 ± 1.1 pmol, which was in complete agreement with the observed X¯0 = 15.0 ± 0.6 pmol, with a mean recovery of 96.0%. This method provides reliable and reproducible results for the quantification of MA in human serum. PMID:19403942
Analysis of anabolic steroids in human hair using LC-MS/MS.
Deshmukh, Nawed; Hussain, Iltaf; Barker, James; Petroczi, Andrea; Naughton, Declan P
2010-10-01
New highly sensitive, specific, reliable, reproducible and robust LC-MS/MS methods were developed to detect the anabolic steroids, nandrolone and stanozolol, in human hair for the first time. Hair samples from 180 participants (108 males, 72 females, 62% athletes) were screened using ELISA which revealed 16 athletes as positive for stanozolol and 3 for nandrolone. Positive samples were confirmed on LC-MS/MS in selective reaction monitoring (SRM) mode. The assays for stanozolol and nandrolone showed good linearity in the range 1-400pg/mg and 5-400pg/mg, respectively. The methods were validated for LLOD, interday precision, intraday precision, specificity, extraction recovery and accuracy. The assays were capable of detecting 0.5pg stanozolol and 3.0pg nandrolone per mg of hair, when approximately 20mg of hair were processed. Analysis using LC-MS/MS confirmed 11 athletes' positive for stanozolol (5.0pg/mg to 86.3pg/mg) and 1 for nandrolone (14.0pg/mg) thus avoiding false results from ELISA screening. The results obtained demonstrate the application of these hair analysis methods to detect both steroids at low concentrations, hence reducing the amount of hair required significantly. The new methods complement urinalysis or blood testing and facilitate improved doping testing regimes. Hair analysis benefits from non-invasiveness, negligible risk of infection and facile sample storage and collection, whilst reducing risks of tampering and cross-contamination. Owing to the wide detection window, this approach may also offer an alternative approach for out-of-competition testing.
LC-PROM: Validation of a patient reported outcomes measure for liver cirrhosis patients.
Zhang, Ying; Yang, Yuanyuan; Lv, Jing; Zhang, Yanbo
2016-05-10
The aim of the study is to develop a specific patient-reported scale of liver cirrhosis according to the Patient Reported Outcome guidelines of the Food and Drug Administration (FDA), and to examine its capacity to fill gaps in this field. A conceptual framework was developed and a preliminary item pool developed through literature review and interviews of 10 patients with liver cirrhosis. With the preliminary items, we performed a pilot survey that included a cognitive test with patients and interviews with experts; the focus was on content and language of the scale. In the item selection stage, seven statistical methods including discrete trends method, discrimination analysis, exploratory factor analysis, Cronbach's α coefficient, correlation coefficient, test-retest reliability, Item-Response Theory were applied to survey data from 200 subjects (150 liver cirrhosis patients and 50 controls). This produced the preliminary Liver Cirrhosis Patient-reported Outcome Measure (LC-PROM). In the next stage, we conducted the survey with 620 subjects (500 patients and 120 controls) to validate reliability, validity and acceptability of this scale. The 55 items and 13 dimensions addressed four domains: physical, psychological, social, and therapeutic. Cronbach's α coefficients were 0.921 for the total scale; the confirmatory factor analysis, t-tests and ANOVA supported scale validity; the model fit index as Root Mean Square Error of Approximation (RMSEA), Root Mean Square Residual (RMR), Normed Fit Index (NFI), Non-Normed Fit Index (NNFI), Comparative Fit Index (CFI) and Incremental Fit Index (IFI) met the criterion generally. The acceptance ratio and response rate indicated good feasibility. This study developed an accurate and stable patient-reported outcome scale of liver cirrhosis, which is able to evaluate clinical effects effectively, is helpful to patients in recognizing their health condition, and contributes to clinical decision making both for patients and physicians. Additionally, the LC-PROM can perform as an ultimate assessment of medical and health care effects and can inform clinical trials of new drugs for liver cirrhosis.
Federal Register 2010, 2011, 2012, 2013, 2014
2010-03-24
... for plant commodities) are both gas liquid chromatography (GLC) methods with electron capture... analytical methodology using liquid chromatography/mass spectrometry/mass spectrometry (LC/MS/MS) detection...-aminopropane]) using gas chromatography (GC) have been submitted to the EPA. In addition, a new validated...
USDA-ARS?s Scientific Manuscript database
Microcystins (MCs) are the most common cyanotoxins found world-wide in freshwater, brackish and marine environments. The rapid and accurate analysis of microcystins and nodularin in fish tissue is important for determining occurrence, monitoring trends, and exposure monitoring for risk assessment a...
Naraharisetti, Suresh Babu; Kirby, Brian J.; Hebert, Mary F.; Easterling, Thomas R.; Unadkat, Jashvant D.
2009-01-01
Glyburide (glibenclamide, INN), a second generation sulfonylurea is widely used in the treatment of gestational diabetes mellitus (GDM). None of the previously reported analytical methods provide adequate sensitivity for the expected sub-nanogram/mL maternal and umbilical cord plasma concentrations of glyburide during pregnancy. We developed and validated a sensitive and low sample volume liquid chromatographic-mass spectrometric (LC-MS) method for simultaneous determination of glyburide (GLY) and its metabolite, 4-transhydroxy glyburide (M1) in human plasma (0.5 ml) or urine (0.1 ml). The limits of quantitation (LOQ) for GLY and M1 in plasma were 0.25 and 0.40 ng/mL, respectively whereas it was 1.06 ng/mL for M1 in urine. As measured by quality control samples, precision (% coefficient of variation) of the assay was < 15% whereas the accuracy (% deviation from expected) ranged from −10.1–14.3%. We found that the GLY metabolite, M1 is excreted in the urine as the glucuronide-conjugate. PMID:17980680
Moukas, Athanasios I; Thomaidis, Nikolaos S; Calokerinos, Antony C
2016-01-01
This study presents the development, optimization, and validation of a novel method for the determination of polychlorinated naphthalenes (PCNs) by liquid chromatography-atmospheric pressure photoionization (APPI), using toluene as dopant. The mass spectra of PCN 52, 54, 66, 67, 73, and 75 were recorded in negative ionization. The base ions corresponded to [M-Cl+O](-), where M is the analyte molecule. A strategy, which includes designs of experiments, for the development, the evaluation, and the optimization of the LC-APPI-MS/MS methods is also described. Finally, a highly sensitive method with low instrumental limits of detection (LoDs), ranging from 0.8 pg for PCN 75 to 16 pg for PCN 54 on column, was validated. A Thermo Hypersil Green PAH (100 mm × 2.1 mm, 3 μm) column was used with acetonitrile/water/methanol as mobile phase. The method was applied for the determination of the selected PCNs in surface and tap water samples. A simple liquid-liquid extraction method for the extraction of PCNs from water samples was used. Method LoQs ranged from 29 ng L(-1), for PCN 73, to 63 ng L(-1), for PCN 54, and the recoveries ranged from 97 to 99%, for all congeners. This is the first LC-APPI-MS/MS method for the determination of PCNs in water samples.
Dickson, Leslie C; O'Byrne, Collin; Chan, Wayne
2012-01-01
An LC/MS/MS-based multiresidue quantitative method was developed for the macrolides erythromycin A, neospiramycin I, oleandomycin, spiramycin I, tilmicosin, and tylosin A in porcine kidney tissues. The Canadian Food Inspection Agency (CFIA) had as part of its analytical scope an LC/UV method for quantification of residues of two macrolide antibiotics, tilmicosin and tylosin A, in the kidney, liver, and muscle of cattle, swine, and poultry. The method could not reliably detect concentrations below 10 microg/kg. To increase the scope of the CFIA's analytical capabilities, a sensitive multiresidue quantitative method for macrolide residues in food animal tissues was required. Porcine kidney samples were extracted with acetonitrile and alkaline buffer and cleaned-up using silica-based C18 SPE cartridges. Sample extracts were analyzed using LC/MS/MS with positive electrospray ionization. Fitness for purpose was verified in a single-laboratory validation study using a second analyst. The working analytical range was 5 to 50 microg/kg. LOD and LOQ were 0.5 to 0.6 microg/kg and 1.5 to 3.0 microg/kg, respectively. Limits of identification were 0.5 to 2.0 microg/kg. Relative intermediate precisions were 8 to 17%. Average absolute recoveries were 68 to 76%.
Bajpai, Vikas; Singh, Awantika; Chandra, Preeti; Negi, M P S; Kumar, Nikhil; Kumar, Brijesh
2016-01-01
The stem of dioecious Tinospora cordifolia (Menispermaceae) is a commonly used traditional Ayurvedic medicine in India having several therapeutic properties. To develop and validate LC-MS methods for the identification and simultaneous quantitation of various secondary metabolites and to study metabolomic variations in the stem of male and female plants. Ethanolic extract of stems were analysed by HPLC/ESI-QTOF-MS/MS for rapid screening of bioactive phytochemicals. High resolution MS and MS/MS in positive ESI mode were used for structural investigation of secondary metabolites. An UPLC/ESI-QqQ(LIT) -MS/MS method in MRM mode was developed and validated for the simultaneous quantitation of five bioactive alkaloids. Identification and characterisation of 36 metabolites including alkaloids, sesquiterpenes and phytoecdysteroids were performed using LC-MS and MS/MS techniques. The bioactive alkaloids such as jatrorrhizine, magnoflorine, isocorydine, palmatine and tetrahydropalmatine were successfully quantified in male and female plants. The mean abundances of magnoflorine jatrorrhizine, and oblongine were significantly (P < 0.05) higher in male plants while mean abundances of tetrahydropalmatine, norcoclaurine, and reticuline were significantly (P < 0.05) higher in female plants. Phytochemicals in the stem of male and female Tinospora cordifolia showed significant qualitative and quantitative variations. LC-MS and MS/MS methods can be used to differentiate between male and female plants based on their chemical profiles and quantities of the marker bioactive alkaloids. This chemical composition difference was also evident during vegetative stage when there were no male and female flowers. Copyright © 2015 John Wiley & Sons, Ltd.
Hummert, Pamela; Parsons, Teresa L; Ensign, Laura M; Hoang, Thuy; Marzinke, Mark A
2018-04-15
The nucleotide reverse transcriptase inhibitor tenofovir (TFV) is widely administered in a disoproxil prodrug form (tenofovir disoproxil fumarate, TDF) for HIV management and prevention. Recently, novel prodrugs tenofovir alafenamide fumarate (TAF) and hexadecyloxypropyl tenofovir (CMX157) have been pursued for HIV treatment while minimizing adverse effects associated with systemic TFV exposure. Dynamic and sensitive bioanalytical tools are required to characterize the pharmacokinetics of these prodrugs in systemic circulation. Two parallel methods have been developed, one to combinatorially quantify TAF and TFV, and a second method for CMX157 quantification, in plasma. K 2 EDTA plasma was spiked with TAF and TFV, or CMX157. Following the addition of isotopically labeled internal standards and sample extraction via solid phase extraction (TAF and TFV) or protein precipitation (CMX157), samples were subjected to liquid chromatographic-tandem mass spectrometric (LC-MS/MS) analysis. For TAF and TFV, separation occurred using a Zorbax Eclipse Plus C18 Narrow Bore RR, 2.1 × 50 mm, 3.5 μm column and analytes were detected on an API5000 mass analyzer; CMX157 was separated using a Kinetex C8, 2.1 × 50 mm, 2.6 μm column and quantified using an API4500 mass spectrometer. Methods were validated according to FDA Bioanalytical Method Validation guidelines. Analytical methods: were optimized for the multiplexed monitoring of TAF and TFV, and CMX157 in plasma. The lower limits of quantification (LLOQs) for TAF, TFV, and CMX157 were 0.03, 1.0, and 0.25 ng/mL, respectively. Calibration curves were generated via weighted linear regression of standards. Intra- and inter-assay precision and accuracy studies demonstrated %CVs ≤ 14.4% and %DEVs ≤ ± 7.95%, respectively. Stability and matrix effects studies were also performed. All results were acceptable and in accordance with the recommended guidelines for bioanalytical methods. Assays were also applied to quantify in vivo concentrations of prodrugs and TFV in a preclinical study post-rectal administration. Sensitive, specific, and dynamic LC-MS/MS assays have been developed and validated for the multiplexed quantification TAF and TFV, as well as an independent assay for CMX157 quantification, in plasma. The described methods meet sufficient throughput criteria to support large research trials. Copyright © 2018 Elsevier B.V. All rights reserved.
Kim, Jihyun; Ji, Dajeong; Kang, Soyoung; Park, Meejung; Yang, Wonkyung; Kim, Eunmi; Choi, Hwakyung; Lee, Sooyeun
2014-02-01
Natural and synthetic opioids have efficient analgesic activity but can also be addictive. Thus, the determination of opioids and their metabolites in biological specimens is of interest in clinical and forensic toxicology laboratories. The analysis of drugs in hair provides valuable information on previous chronic drug use and has been successfully applied to the diagnosis of drug abuse, tolerance, compliance and gestational drug exposure. Despite the abuse of prescription opioids along with heroin and other illegal opiates, few studies have been conducted on the simultaneous determination of the broad range of opioids covering those drugs in hair. In the present study, an analytical method for the simultaneous detection in hair of 18 opioids and metabolites considered to have a high abuse risk based on the results of urine drug screening was established and validated using liquid chromatography-tandem mass spectrometry (LC-MS/MS) for the purpose of clinical and forensic applications. The drugs and metabolites were extracted from hair using methanol and analyzed using LC-MS/MS. The validation results proved that the method was selective, accurate and precise with acceptable linearity within calibration ranges. No significant variation was observed by different sources of matrices. The limits of detection and the limits of quantification ranged from 0.05 to 0.25ng/10mg hair and from 0.05 to 0.5ng/10mg hair, respectively. The developed method was successfully applied to 15 hair samples from opioids users. This method will be very useful for monitoring the inappropriate use of opioid drugs. Copyright © 2013 Elsevier B.V. All rights reserved.
Cai, Shuang; Wang, Lei
2012-05-15
A simple and rapid high-performance liquid chromatography-electrospray ionization tandem mass spectrometry (LC-ESI-MS/MS) method has been developed and validated for the determination of 4-p-anisamidobutyric acid (ABA; or N-anysoyl-γ-aminobutiryc acid, N-anisoyl-GABA), a major active metabolite of aniracetam, in human plasma. After protein precipitation of plasma sample with methanol, ABA and the internal standard lisinopril were separated on a Venusil ASB C₁₈ column at 25 °C. The mobile phase consisted of methanol-ammonium acetate (10 mmol/L) (30:70, v/v). The detection was performed on a triple quadrupole tandem mass spectrometer with an ESI source in negative ion mode. Multiple reaction monitoring (MRM) using the precursor→product ion combinations of m/z 235.8→m/z 106.6, and m/z 403.8→m/z 113.6 was used to quantify ABA and lisinopril, respectively. This is the first LC-MS/MS method for ABA with advantages of short analysis time (4.5 min per sample run) and high selectivity attributable to the MRM detection and optimized HPLC conditions. The response was linear in a concentration range of 0.0485-19.4 μg/mL in plasma. The extraction recovery of ABA was between 89.1% and 100.7%. The precision (RSD) and accuracy (RE) of the method were evaluated to be within 7.3% and from 2.5% to 6.9%. The validated method has been applied to the pharmacokinetic study after a single oral administration of aniracetam dispersible tablets to human beings. Copyright © 2012 Elsevier B.V. All rights reserved.
Jang, Moonhee; Kim, Jihyun; Han, Inhoi; Yang, Wonkyung
2015-11-10
Lysergic acid diethylamide (LSD) is administered in low dosages, which makes its detection in biological matrices a major challenge in forensic toxicology. In this study, two sensitive and reliable methods based on liquid chromatography-tandem mass spectrometry (LC-MS/MS) were established and validated for the simultaneous determination of LSD and its metabolite, 2-oxo-3-hydroxy-LSD (O-H-LSD), in hair and urine. Target analytes in hair were extracted using methanol at 38°C for 15h and analyzed by LC-MS/MS. For urine sample preparation, liquid-liquid extraction was performed. Limits of detection (LODs) in hair were 0.25pg/mg for LSD and 0.5pg/mg for O-H-LSD. In urine, LODs were 0.01 and 0.025ng/ml for LSD and O-H-LSD, respectively. Method validation results showed good linearity and acceptable precision and accuracy. The developed methods were applied to authentic specimens from two legal cases of LSD ingestion, and allowed identification and quantification of LSD and O-H-LSD in the specimens. In the two cases, LSD concentrations in hair were 1.27 and 0.95pg/mg; O-H-LSD was detected in one case, but its concentration was below the limit of quantification. In urine samples collected from the two suspects 8 and 3h after ingestion, LSD concentrations were 0.48 and 2.70ng/ml, respectively, while O-H-LSD concentrations were 4.19 and 25.2ng/ml, respectively. These methods can be used for documenting LSD intake in clinical and forensic settings. Copyright © 2015 Elsevier B.V. All rights reserved.
Robandt, P V; Klette, K L; Sibum, M
2009-10-01
An automated solid-phase extraction coupled with liquid chromatography and tandem mass spectrometry (SPE-LC-MS-MS) method for the analysis of 11-nor-Delta(9)-tetrahydrocannabinol-9-carboxylic acid (THC-COOH) in human urine specimens was developed. The method was linear (R(2) = 0.9986) to 1000 ng/mL with no carryover evidenced at 2000 ng/mL. Limits of quantification and detection were found to be 2 ng/mL. Interrun precision was evaluated at the 15 ng/mL level over nine batches spanning 15 days (n = 45). The coefficient of variation (%CV) was found to be 5.5% over the course of the validation. Intrarun precision of a 15 ng/mL control (n = 5) ranged from 0.58% CV to 7.4% CV for the same set of analytical batches. Interference was tested using (+/-)-11-hydroxy-Delta(9)-tetrahydrocannabinol, cannabidiol, (-)-Delta(8)-tetrahydrocannabinol, and cannabinol. One hundred and nineteen specimens previously found to contain THC-COOH by a previously validated gas chromatographic mass spectrometry (GC-MS) procedure were compared to the SPE-LC-MS-MS method. Excellent agreement was found (R(2) = 0.9925) for the parallel comparison study. The automated SPE procedure eliminates the human factors of specimen handling, extraction, and derivatization, thereby reducing labor costs and rework resulting from human error or technique issues. Additionally, method runtime is greatly reduced (e.g., during parallel studies the SPE-LC-MS-MS instrument was often finished with analysis by the time the technician finished the offline SPE and derivatization procedure prior to the GC-MS analysis).
Kallem, Raja Reddy; Jillela, Bhupathi; Ravula, Arun Reddy; Samala, Ramakrishna; Andy, Adinarayana; Ramesh, Mullangi; Rao, Jvln Seshagiri
2016-06-01
A selective, sensitive and rapid LC-MS/MS method has been developed and validated for quantification of the phenelzine (PZ) in 200μL of human plasma using hydroxyzine (HZ) as an internal standard (IS) as per regulatory guidelines. The sample preparation involved the derivatization of PZ using pentaflurobenzaldehyde followed by solid phase extraction process to extract PZ and HZ from human plasma. LC-MS/MS was operated under the multiple reaction-monitoring mode (MRM) using the electro spray ionization technique in positive ion mode and the transitions of m/z 305.1→105.1 and m/z 375.3→201.1 were used to measure the derivative of PZ and IS, respectively. The total run time was 3.5min and the elution of PZ and HZ occurred at 2.53, and 1.92min, respectively; this was achieved with a mobile phase consisting of 10mM ammonium acetate: acetonitrile (20:80, v/v) at a flow rate of 1.0mL/min on an Ace C18 column with a split ratio of 70:30. The developed method was validated in human plasma with a lower limit of quantitation 0.51ng/mL. A linear response function was established for the range of concentrations 0.51-25.2ng/mL (r>0.995) for PZ. The intra- and inter-day precision values met the acceptance criteria. PZ was stable in the battery of stability studies viz., stock solution, bench-top, auto-sampler, long-term and freeze/thaw cycles. The developed assay method was applied to an oral bioequivalence study in humans. Copyright © 2016 Elsevier B.V. All rights reserved.
Bushman, Lane R; Kiser, Jennifer J; Rower, Joseph E; Klein, Brandon; Zheng, Jia-Hua; Ray, Michelle L; Anderson, Peter L
2011-09-10
An ultra-sensitive liquid chromatography tandem mass spectrometry (LC-MS/MS) assay was developed and validated to facilitate the assessment of clinical pharmacokinetics of nucleotide analogs from lysed intracellular matrix. The method utilized a strong anion exchange isolation of mono-(MP), di-(DP), and tri-phosphates (TP) from intracellular matrix. Each fraction was then dephosphorylated to the parent moiety yielding a molar equivalent to the original nucleotide analog intracellular concentration. The analytical portion of the methodology was optimized in specific nucleoside analog centric modes (i.e. tenofovir (TFV) centric, zidovudine (ZDV) centric), which included desalting/concentration by solid phase extraction and detection by LC-MS/MS. Nucleotide analog MP-, DP-, and TP-determined on the TFV centric mode of analysis include TFV, lamivudine (3TC), and emtricitibine (FTC). The quantifiable linear range for TFV was 2.5-2000 fmol/sample, and that for 3TC/FTC was 0.1 200 pmol/sample. Nucleoside analog MP-, DP-, and TP-determined on the ZDV centric mode of analysis included 3TC and ZDV. The quantifiable linear range for 3TC was 0.1 100 pmol/sample, and 5-2000 fmol/sample for ZDV. Stable labeled isotopic internal standards facilitated accuracy and precision in alternative cell matrices, which supported the intended use of the method for MP, DP, and TP determinations in various cell types. The method was successfully applied to clinical research samples generating novel intracellular information for TFV, FTC, ZDV, and 3TC nucleotides. This document outlines method development, validation, and application to clinical research. Copyright © 2011 Elsevier B.V. All rights reserved.
Milosheska, Daniela; Roškar, Robert
2017-05-10
The aim of the present report was to develop and validate simple, sensitive and reliable LC-MS/MS method for quantification of topiramate (TPM) and its main metabolites: 2,3-desisopropylidene TPM, 4,5-desisopropylidene TPM, 10-OH TPM and 9-OH TPM in human plasma samples. The most abundant metabolite 2,3-desisopropylidene TPM was isolated from patients urine, characterized and afterwards used as an authentic standard for method development and validation. Sample preparation method employs 100μL of plasma sample and liquid-liquid extraction with a mixture of ethyl acetate and diethyl ether as extraction solvent. Chromatographic separation was achieved on a 1290 Infinity UHPLC coupled to 6460 Triple Quad Mass Spectrometer operated in negative MRM mode using Kinetex C18 column (50×2.1mm, 2.6μm) by gradient elution using water and methanol as a mobile phase and stable isotope labeled TPM as internal standard. The method showed to be selective, accurate, precise and linear over the concentration ranges of 0.10-20μg/mL for TPM, 0.01-2.0μg/mL for 2,3-desisopropylidene TPM, and 0.001-0.200μg/mL for 4,5-desisopropylidene TPM, 10-OH TPM and 9-OH TPM. The described method is the first fully validated method capable of simultaneous determination of TPM and its main metabolites in plasma over the selected analytical range. The suitability of the method was successfully demonstrated by the quantification of all analytes in plasma samples of patients with epilepsy and can be considered as reliable analytical tool for future investigations of the TPM metabolism. Copyright © 2017 Elsevier B.V. All rights reserved.
Gesquiere, Laurence R.; Ziegler, Toni E.; Chen, Patricia A.; Epstein, Katherine A.; Alberts, Susan C.; Altmann, Jeanne
2014-01-01
The development of non-invasive methods, particularly fecal determination, has made possible the assessment of hormone concentrations in wild animal populations. However, measuring fecal metabolites needs careful validation for each species and for each sex. We investigated whether radioimmunoassays (RIAs) previously used to measure fecal testosterone (fT) in male baboons and fecal estrogens (fE) in female baboons were well suited to measure these hormones in the opposite sex. We compared fE and fT concentrations determined by RIA to those measured by liquid chromatography combined with triple quadropole mass spectrometry (LC/MS/MS), a highly specific method. Additionally, we conducted a biological validation to assure that the measurements of fecal concentrations reflected physiological levels of the hormone of interest. Several tests produced expected results that led us to conclude that our RIAs can reliably measure fT and fE in both sexes, and that within-sex comparisons of these measures are valid: (i) fTRIA were significantly correlated to fTLC/MS/MS for both sexes; (ii) fTRIA were higher in adult than in immature males; (iii) fTRIA were higher in pregnant than non-pregnant females; (iv) fERIA were correlated with 17β-estradiol (fE2) and with estrone (fE1) determined by LC/MS/MS in pregnant females; (v) fERIA were significantly correlated with fE2 in non-pregnant females and nearly significantly correlated in males; (vi) fERIA were higher in adult males than in immature males. fERIA were higher in females than in males, as predicted, but unexpectedly, fTRIA were higher in females than in males, suggesting a difference in steroid metabolism in the two sexes; consequently, we conclude that while within-sex comparisons are valid, fTRIA should not be used for intersexual comparisons. Our results should open the field to important additional studies, as to date the roles of testosterone in females and estrogens in males have been little investigated. PMID:24798581
Li, Xiaofang; Parks, Elizabeth J; McLaren, David G; Lambert, Jennifer E; Cardasis, Helene L; Chappell, Derek L; McAvoy, Thomas; Salituro, Gino; Alon, Achilles; Dennie, Justin; Chakravarthy, Manu; Shankar, Sudha S; Laterza, Omar F; Lassman, Michael E
2016-06-01
A traditional oral fatty acid challenge assesses absorption of triacylglycerol (TG) into the periphery through the intestines, but cannot distinguish the composition or source of fatty acid in the TG. Stable isotope-labeled tracers combined with LC-MRM can be used to identify and distinguish TG synthesized with dietary and stored fatty acids. Concentrations of three abundant TGs (52:2, 54:3 and 54:4) were monitored for incorporation of one or two (2)H11-oleate molecules per TG. This method was subjected to routine assay validation and meets typical requirements for an assay to be used to support clinical studies. Calculations for the fractional appearance rate of TG in plasma are presented along with the intracellular enterocyte precursor pool for 12 study participants.
Abu-Awwad, Ahmad; Arafat, Tawfiq; Schmitz, Oliver J
2016-09-01
Nicotine (Nic) distribution in human fluids and tissues has a deleterious effect on human health. In addition to its poisoning profile, Nic may contribute to the particular impact of smoking on human reproduction. Although present in seminal fluid, still nobody knows whether nicotine is available in sperm or not. Herein, we developed and validated a new bioanalytical method, for simultaneous determination of Nic, cotinine (Cot), and nicotine N'-oxide (Nox) in human plasma, semen, and sperm by LC-ESI-orbitrap-MS. Blood and semen samples were collected from 12 healthy smoking volunteers in this study. Sperm bodies were then separated quantitatively from 1 mL of semen samples by centrifugation. The developed method was fully validated for plasma following European and American guidelines for bioanalytical method validation, and partial validation was applied to semen analysis. Plasma, semen, and sperm samples were treated by trichloroacetic acid solution for protein direct precipitation in single extraction step. The established calibration range for Nic and Nox in plasma and semen was linear between 5 and 250 ng/mL, and for Cot between 10 and 500 ng/mL. Nic and Cot were detected in human sperm at concentrations as high as in plasma. In addition, Nox was present in semen and sperm but not in plasma. Graphical abstract Nicotine correlation between plasma and semen a; Nicotine correlation between semen and sperm c; Cotinine correlation between plasma and semen b; Cotinine correlation between semen and sperm d.
Brêtas, Juliana Machado; César, Isabela Costa; Brêtas, Camila Machado; Teixeira, Leonardo de Souza; Bellorio, Karini Bruno; Mundim, Iram Moreira; Pianetti, Gerson Antônio
2016-06-01
A sensitive and fast liquid chromatography-electrospray ionization tandem mass spectrometry (LC-ESI-MS/MS) method was developed and validated for the simultaneous quantification of naproxen and sumatriptan in human plasma. A simple liquid-liquid extraction procedure, with a mixture of ethyl acetate, methyl tert-butyl ether, and dichloromethane (4:3:3, v/v), was used for the cleanup of plasma. Naratriptan and aceclofenac were employed as internal standards. The analyses were carried out using an ACE C18 column (50 × 4.6 mm i.d.; particle size 5 μm) and a mobile phase consisting of 2 mM aqueous ammonium acetate with 0.025 % formic acid and methanol (38:62, v/v). A triple-quadrupole mass spectrometer equipped with an electrospray source in the positive mode was set up in the selective reaction monitoring mode to detect the ion transitions m/z 231.67 → m/z 185.07, m/z 296.70 → m/z 157.30, m/z 354.80 → m/z 215.00, and m/z 336.80 → m/z 97.94 for naproxen, sumatriptan, aceclofenac, and naratriptan, respectively. The method was validated and proved to be linear, accurate, precise, and selective over the ranges of 2.5-130 μg mL(-1) for naproxen and 1-50 ng mL(-1) for sumatriptan. The validated method was successfully applied to a pharmacokinetic study with simultaneous administration of naproxen sodium and sumatriptan succinate tablet formulations in healthy volunteers.
Nijenhuis, C M; Rosing, H; Schellens, J H M; Beijnen, J H
2014-01-01
Vemurafenib is an inhibitor of mutated serine/threonine-protein kinase B-Raf (BRAF) and is registered as Zelboraf(®) for the treatment of adult patients with BRAF V600 mutation-positive unresectable or metastatic melanoma. To support Therapeutic Drug Monitoring (TDM) and clinical trials, we developed and validated a method for the quantification of vemurafenib in human plasma. Additionally two LC-MS systems with different detectors were tested: the TSQ Quantum Ultra and the API3000. Human plasma samples were collected in the clinic and stored at nominally -20°C. Vemurafenib was isolated from plasma by liquid-liquid extraction, separated on a C18 column with gradient elution, and analysed with triple quadrupole mass spectrometry in positive-ion mode. A stable isotope was used as internal standard for the quantification. Ranging from 1 to 100μg/ml the assay was linear with correlation coefficients (r(2)) of 0.9985 or better. Inter-assay and intra-assay accuracies were within ±7.6% of the nominal concentration; inter-assay and intra-assay precision were within ≤9.3% of the nominal concentration. In addition all results were within the acceptance criteria of the US FDA and the latest EMA guidelines for method validation for both MS detectors. In conclusion, the presented analytical method for vemurafenib in human plasma was successfully validated and the performance of the two LC-MS systems for this assay was comparable. In addition the method was successfully applied to evaluate the pharmacokinetic quantification of vemurafenib in cancer patients treated with vemurafenib. Copyright © 2013 Elsevier B.V. All rights reserved.
Yi, Ling; Qi, Lian-Wen; Li, Ping; Ma, Yi-Han; Luo, Yong-Jing; Li, Hai-Yun
2007-09-01
Danggui Buxue Tang (DBT), a classical traditional Chinese formula comprising Radix Angelicae Sinensis (RAS) and Radix Astragali (RA), has been widely used to treat menopausal irregularity in Chinese women for nearly 800 years. In this study, a comprehensive analytical method of simultaneously determining the main types of bioactive constituents, eighteen in all from the formula, involving flavonoids, saponins, organic acid and some volatile compounds, was developed. This method was based on HPLC coupled to a diode array and evaporative light scattering detectors (HPLC-DAD-ELSD) on a common reverse-phase C(18) column. Liquid chromatography coupled with on-line electrospray ionization mass spectrometry (LC-ESI-MS) was also used to further validate and analyze the constituents. It was found that 0.3% aqueous formic acid and acetonitrile was the optimum mobile phase for gradient elution. This method, which showed good precision and accuracy, was successfully used to quantify the bioactive constituents in six products. As a result, the validated HPLC method, together with the LC-ESI-MS analysis, provided a new basis for assessing the quality of traditional Chinese medicinal compound preparations (TCMCPs) consisting of many bioactive components.
Palazzoli, Federica; Citti, Cinzia; Licata, Manuela; Vilella, Antonietta; Manca, Letizia; Zoli, Michele; Vandelli, Maria Angela; Forni, Flavio; Cannazza, Giuseppe
2018-02-20
The investigation of the possible conversion of cannabidiol (CBD) into Δ 9 -tetrahydrocannabinol (THC) in vivo after oral administration of CBD is reported herein since recent publications suggested a rapid conversion in simulated gastric fluid. To this end, single high dose of CBD (50mg/kg) was administered orally to rats and their blood was collected after 3 and 6h. A highly sensitive and selective LC-MS/MS method was developed and fully validated in compliance with the Scientific Working Group of Forensic Toxicology (SWGTOX) standard practices for method validation in forensic toxicology. This method also involved the optimization of cannabinoids and their metabolites extraction in order to remove co-eluting phospholipids and increase the sensitivity of the MS detection. Neither THC nor its metabolites were detected in rat whole blood after 3 or 6h from CBD administration. After oral administration, the amount of CBD dissolved in olive oil was higher than that absorbed from an ethanolic solution. This could be explained by the protection of lipid excipients towards CBD from acidic gastric juice. Copyright © 2017 Elsevier B.V. All rights reserved.
Chiu, Huai-Hsuan; Liao, Hsiao-Wei; Shao, Yu-Yun; Lu, Yen-Shen; Lin, Ching-Hung; Tsai, I-Lin; Kuo, Ching-Hua
2018-08-17
Monoclonal antibody (mAb) drugs have generated much interest in recent years for treating various diseases. Immunoglobulin G (IgG) represents a high percentage of mAb drugs that have been approved by the Food and Drug Administration (FDA). To facilitate therapeutic drug monitoring and pharmacokinetic/pharmacodynamic studies, we developed a general liquid chromatography-tandem mass spectrometry (LC-MS/MS) method to quantify the concentration of IgG-based mAbs in human plasma. Three IgG-based drugs (bevacizumab, nivolumab and pembrolizumab) were selected to demonstrate our method. Protein G beads were used for sample pretreatment due to their universal ability to trap IgG-based drugs. Surrogate peptides that were obtained after trypsin digestion were quantified by using LC-MS/MS. To calibrate sample preparation errors and matrix effects that occur during LC-MS/MS analysis, we used two internal standards (IS) method that include the IgG-based drug-IS tocilizumab and post-column infused IS. Using two internal standards was found to effectively improve quantification accuracy, which was within 15% for all mAb drugs that were tested at three different concentrations. This general method was validated in term of its precision, accuracy, linearity and sensitivity for 3 demonstration mAb drugs. The successful application of the method to clinical samples demonstrated its' applicability in clinical analysis. It is anticipated that this general method could be applied to other mAb-based drugs for use in precision medicine and clinical studies. Copyright © 2018 Elsevier B.V. All rights reserved.
Singh, Pritam; Aggarwal, Rajesh; Tahir, Muaaz; Pucher, Philip H; Darzi, Ara
2015-05-01
This study evaluates whether video-based coaching can enhance laparoscopic surgical skills performance. Many professions utilize coaching to improve performance. The sports industry employs video analysis to maximize improvement from every performance. Laparoscopic novices were baseline tested and then trained on a validated virtual reality (VR) laparoscopic cholecystectomy (LC) curriculum. After competence, subjects were randomized on a 1:1 ratio and each performed 5 VRLCs. After each LC, intervention group subjects received video-based coaching by a surgeon, utilizing an adaptation of the GROW (Goals, Reality, Options, Wrap-up) coaching model. Control subjects viewed online surgical lectures. All subjects then performed 2 porcine LCs. Performance was assessed by blinded video review using validated global rating scales. Twenty subjects were recruited. No significant differences were observed between groups in baseline performance and in VRLC1. For each subsequent repetition, intervention subjects significantly outperformed controls on all global rating scales. Interventions outperformed controls in porcine LC1 [Global Operative Assessment of Laparoscopic Skills: (20.5 vs 15.5; P = 0.011), Objective Structured Assessment of Technical Skills: (21.5vs 14.5; P = 0.001), and Operative Performance Rating System: (26 vs 19.5; P = 0.001)] and porcine LC2 [Global Operative Assessment of Laparoscopic Skills: (28 vs 17.5; P = 0.005), Objective Structured Assessment of Technical Skills: (30 vs 16.5; P < 0.001), and Operative Performance Rating System: (36 vs 21; P = 0.004)]. Intervention subjects took significantly longer than controls in porcine LC1 (2920 vs 2004 seconds; P = 0.009) and LC2 (2297 vs 1683; P = 0.003). Despite equivalent exposure to practical laparoscopic skills training, video-based coaching enhanced the quality of laparoscopic surgical performance on both VR and porcine LCs, although at the expense of increased time. Video-based coaching is a feasible method of maximizing performance enhancement from every clinical exposure.
Analysis of 70 Environmental Protection Agency priority pharmaceuticals in water by EPA Method 1694.
Ferrer, Imma; Zweigenbaum, Jerry A; Thurman, E Michael
2010-09-03
The U.S. Environmental Protection Agency (EPA) Method 1694 for the determination of pharmaceuticals in water recently brought a new challenge for treatment utilities, where pharmaceuticals have been reported in the drinking water of 41-million Americans. This proposed methodology, designed to address this important issue, consists of solid-phase extraction (SPE) followed by liquid chromatography-mass spectrometry (LC/MS-MS) using triple quadrupole. Under the guidelines of Method 1694, a multi-residue method was developed, validated, and applied to wastewater, surface water and drinking water samples for the analysis of 70 pharmaceuticals. Four distinct chromatographic gradients and LC conditions were used according to the polarity and extraction of the different pharmaceuticals. Positive and negative ion electrospray were used with two MRM transitions (a quantifier and a qualifier ion for each compound), which adds extra confirmation not included in the original Method 1694. Finally, we verify, for the first time, EPA Method 1694 on water samples collected in several locations in Colorado, where positive identifications for several pharmaceuticals were found. This study is a valuable indicator of the potential of LC/MS-MS for routine quantitative multi-residue analysis of pharmaceuticals in drinking water and wastewater samples and will make monitoring studies much easier to develop for water utilities across the US, who are currently seeking guidance on analytical methods for pharmaceuticals in their water supplies. 2010 Elsevier B.V. All rights reserved.
Lehmann, Sabrina; Kieliba, Tobias; Beike, Justus; Thevis, Mario; Mercer-Chalmers-Bender, Katja
2017-10-01
A detailed description is given of the development and validation of a fully automated in-line solid-phase extraction-liquid chromatography-tandem mass spectrometry (SPE-LC-MS/MS) method capable of detecting 90 central-stimulating new psychoactive substances (NPS) and 5 conventional amphetamine-type stimulants (amphetamine, 3,4-methylenedioxy-methamphetamine (MDMA), 3,4-methylenedioxy-amphetamine (MDA), 3,4-methylenedioxy-N-ethyl-amphetamine (MDEA), methamphetamine) in serum. The aim was to apply the validated method to forensic samples. The preparation of 150μL of serum was performed by an Instrument Top Sample Preparation (ITSP)-SPE with mixed mode cation exchanger cartridges. The extracts were directly injected into an LC-MS/MS system, using a biphenyl column and gradient elution with 2mM ammonium formate/0.1% formic acid and acetonitrile/0.1% formic acid as mobile phases. The chromatographic run time amounts to 9.3min (including re-equilibration). The total cycle time is 11min, due to the interlacing between sample preparation and analysis. The method was fully validated using 69 NPS and five conventional amphetamine-type stimulants, according to the guidelines of the Society of Toxicological and Forensic Chemistry (GTFCh). The guidelines were fully achieved for 62 analytes (with a limit of detection (LOD) between 0.2 and 4μg/L), whilst full validation was not feasible for the remaining 12 analytes. For the fully validated analytes, the method achieved linearity in the 5μg/L (lower limit of quantification, LLOQ) to 250μg/L range (coefficients of determination>0.99). Recoveries for 69 of these compounds were greater than 50%, with relative standard deviations≤15%. The validated method was then tested for its capability in detecting a further 21 NPS, thus totalling 95 tested substances. An LOD between 0.4 and 1.6μg/L was obtained for these 21 additional qualitatively-measured substances. The method was subsequently successfully applied to 28 specimens from routine forensic case work, of which 7 samples were determined to be positive for NPS consumption. Copyright © 2017 Elsevier B.V. All rights reserved.
Paul, Atish T; Vir, Sanjay; Bhutani, K K
2008-10-24
A new liquid chromatography-mass spectrometry (LC-MS)-based method coupled with pressurized liquid extraction (PLE) as an efficient sample preparation technique has been developed for the quantification and fingerprint analysis of Solanum xanthocarpum. Optimum separations of the samples were achieved on a Waters MSC-18 XTerra column, using 0.5% (v/v) formic acid in water (A) and acetonitrile (ACN):2-propanol:formic acid (94.5:5:0.5, v/v/v) (B) as mobile phase. The separation was carried out using linear gradient elution with a flow rate of 1.0mL/min. The gradient was: 0min, 20% B; 14min, 30% B; 20min, 30% B; 27min, 60% B and the column was re-equilibrated to the initial condition (20% B) for 10min prior to next injection. The steroidal glycoalkaloids (SGAs) which are the major active constituents were isolated as pure compounds from the crude methanolic extract of S. xanthocarpum by preparative LC-MS and after characterization were used as external standards for the development and validation of the method. Extracts prepared by conventional Soxhlet extraction, PLE and ultrasonication were used for analysis. The method was validated for repeatability, precision (intra- and inter-day variation), accuracy (recovery) and sensitivity (limit of detection and limit of quantitation). The purpose of the work was to develop a validated method, which can be used for the quantification of SGAs in commercialized S. xanthocarpum products and the fingerprint analysis for their routine quality control.
Gowda, Nagaraj; Kumar, Pradeep; Panghal, Surender; Rajshree, Mashru
2010-02-01
This study presents the development and validation of a reversed-phase liquid chromatographic method for the determination of mangiferin (MGN) in alcoholic extracts of mangifera indica. A Lichrospher 100 C(18)-ODS (250 x 4.6 mm, 5 microm size) (Merck, Whitehouse Station, NJ) prepacked column and a mobile phase of potassium dihydrogen orthophosphate (0.01M) pH 2.7 +/- 0.2-acetonitrile (15:85, v/v) with the flow rate of 1 mL/min was used. MGN detection was achieved at a wavelength monitored at 254 nm with SPD-M 10A vp PDA detector or SPD 10AD vp UV detector in combination with class LC 10A software. The proposed method was validated as prescribed by International Conference on Harmonization (ICH) with respect to linearity, specificity, accuracy, precision, stability, and quantification. The method validation was realized using alcoholic extracts and raw materials of leaves and barks. All the validation parameters were within the acceptable limits, and the developed analytical method can successfully be applied for MGN determination.
Alberti, Ágnes; Béni, Szabolcs; Lackó, Erzsébet; Riba, Pál; Al-Khrasani, Mahmoud; Kéry, Ágnes
2012-11-01
Sempervivum tectorum L. (houseleek) leaf juice has been known as a traditional herbal remedy. The aim of the present study was the chemical characterization of its phenolic compounds and to develop quantitation methods for its main flavonol glycoside, as well as to evaluate its antinociceptive activity. Lyophilized houseleek leaf juice was studied by HPLC-DAD coupled to electrospray ionization tandem mass spectrometry (LC-ESI-MS/MS) to identify flavonol glycosides, hydroxy-benzoic and hydroxy-cinnamic acids. Ten flavonol glycosides and sixteen phenolic acid compounds were identified or tentatively characterized. Structure of the main flavonol compound was identified by nuclear magnetic resonance spectroscopy. Three characteristic kaempferol glycosides were isolated and determined by LC-ESI-MS/MS with external calibration method, using the isolated compounds as standard. The main flavonol glycoside was also determined by HPLC-DAD. Validated HPLC-DAD and LC-ESI-MS/MS methods were developed to quantify kaempferol-3-O-rhamnosyl-glucoside-7-O-rhamnoside and two other kaempferol glycosides. Antinociceptive activity of houseleek leaf juice was investigated by writhing test of mice. Sempervivum extract significantly reduced pain in the mouse writhing test. Copyright © 2012 Elsevier B.V. All rights reserved.
Guo, Pengqi; Xu, Xinya; Xian, Liang; Ge, Yanhui; Luo, Zhimin; Du, Wei; Jing, Wanghui; Zeng, Aiguo; Chang, Chun; Fu, Qiang
2016-12-01
Nowadays, the illegal use of estradiol in cosmetics has caused a series of events which endangering public health seriously. Therefore, it is imperative to establish a simple, fast and specific method for monitoring the illegal use of estradiol in cosmetics. In current study, we developed a molecular imprinted monolithic column two dimensional liquid chromatography method (MIMC-2D-LC) for rapid and selective determination of estradiol in various cosmetic samples. The best polymerization, morphology, structure property, surface groups, and the adsorption performance of the prepared material were investigated. The MIMC-2D-LC was validated and successfully used for detecting estradiol in cosmetic samples with good selectivity, sensitivity, efficiency and reproducibility. The linear range of the MIMC-2D-LC for estradiol was 0.5-50μgg -1 with the limit of detection of 0.08μgg -1 . Finally, six batches of cosmetic samples obtained from local markets were tested by the proposed method. The test results showed that the illegal use of estradiol still existed in the commercially available samples. Copyright © 2016 Elsevier B.V. All rights reserved.
Ma, Jianshe; Cai, Jinzhang; Lin, Guanyang; Chen, Huilin; Wang, Xianqin; Wang, Xianchuan; Hu, Lufeng
2014-05-15
Corynoxeine(CX), isolated from the extract of Uncaria rhynchophylla, is a useful and prospective compound in the prevention and treatment for vascular diseases. A simple and selective liquid chromatography mass spectrometry (LC-MS) method was developed to determine the concentration of CX in rat plasma. The chromatographic separation was achieved on a Zorbax SB-C18 (2.1 mm × 150 mm, 5 μm) column with acetonitrile-0.1% formic acid in water as mobile phase. Selective ion monitoring (SIM) mode was used for quantification using target ions m/z 383 for CX and m/z 237 for the carbamazepine (IS). After the LC-MS method was validated, it was applied to a back-propagation artificial neural network (BP-ANN) pharmacokinetic model study of CX in rats. The results showed that after intravenous administration of CX, it was mainly distributed in blood and eliminated quickly, t1/2 was less than 1h. The predicted concentrations generated by BP-ANN model had a high correlation coefficient (R>0.99) with experimental values. The developed BP-ANN pharmacokinetic model can be used to predict the concentration of CX in rats. Copyright © 2014 Elsevier B.V. All rights reserved.
Accuracy assessment of seven global land cover datasets over China
NASA Astrophysics Data System (ADS)
Yang, Yongke; Xiao, Pengfeng; Feng, Xuezhi; Li, Haixing
2017-03-01
Land cover (LC) is the vital foundation to Earth science. Up to now, several global LC datasets have arisen with efforts of many scientific communities. To provide guidelines for data usage over China, nine LC maps from seven global LC datasets (IGBP DISCover, UMD, GLC, MCD12Q1, GLCNMO, CCI-LC, and GlobeLand30) were evaluated in this study. First, we compared their similarities and discrepancies in both area and spatial patterns, and analysed their inherent relations to data sources and classification schemes and methods. Next, five sets of validation sample units (VSUs) were collected to calculate their accuracy quantitatively. Further, we built a spatial analysis model and depicted their spatial variation in accuracy based on the five sets of VSUs. The results show that, there are evident discrepancies among these LC maps in both area and spatial patterns. For LC maps produced by different institutes, GLC 2000 and CCI-LC 2000 have the highest overall spatial agreement (53.8%). For LC maps produced by same institutes, overall spatial agreement of CCI-LC 2000 and 2010, and MCD12Q1 2001 and 2010 reach up to 99.8% and 73.2%, respectively; while more efforts are still needed if we hope to use these LC maps as time series data for model inputting, since both CCI-LC and MCD12Q1 fail to represent the rapid changing trend of several key LC classes in the early 21st century, in particular urban and built-up, snow and ice, water bodies, and permanent wetlands. With the highest spatial resolution, the overall accuracy of GlobeLand30 2010 is 82.39%. For the other six LC datasets with coarse resolution, CCI-LC 2010/2000 has the highest overall accuracy, and following are MCD12Q1 2010/2001, GLC 2000, GLCNMO 2008, IGBP DISCover, and UMD in turn. Beside that all maps exhibit high accuracy in homogeneous regions; local accuracies in other regions are quite different, particularly in Farming-Pastoral Zone of North China, mountains in Northeast China, and Southeast Hills. Special attention should be paid for data users who are interested in these regions.
Screening of 23 β-lactams in foodstuffs by LC-MS/MS using an alkaline QuEChERS-like extraction.
Bessaire, Thomas; Mujahid, Claudia; Beck, Andrea; Tarres, Adrienne; Savoy, Marie-Claude; Woo, Pei-Mun; Mottier, Pascal; Desmarchelier, Aurélien
2018-04-01
A fast and robust high performance LC-MS/MS screening method was developed for the analysis of β-lactam antibiotics in foods of animal origin: eggs, raw milk, processed dairy ingredients, infant formula, and meat- and fish-based products including baby foods. QuEChERS extraction with some adaptations enabled 23 drugs to be simultaneously monitored. Screening target concentrations were set at levels adequate to ensure compliance with current European, Chinese, US and Canadian regulations. The method was fully validated according to the European Community Reference Laboratories Residues Guidelines using 93 food samples of different composition. False-negative and false-positive rates were below 5% for all analytes. The method is adequate for use in high-routine laboratories. A 1-year study was additionally conducted to assess the stability of the 23 analytes in the working standard solution.
Wang, Qing; Zhao, Hua; Xi, Cunxian; Wang, Guomin; Chen, Dongdong; Ding, Shijia
2014-01-01
An immunoaffinity column clean-up and LC-MS/MS method was successfully developed for simultaneous determination of chloramphenicol, zearalanone, α-zearalanol, β-zearalanol, zearalenone, α-zearalenol and β-zearalenol in pig muscle. The sample was extracted with diethyl ether after enzymatic digestion by β-glucuronidase/sulfatase. The extracted solution was evaporated to dryness and the residue was then dissolved in 1 ml of 50% acetonitrile solution. After filtration and dilution with phosphate buffer solution (PBS), the reconstituted solution was cleaned-up with an IAC-CZ immunoaffinity column and then analysed by HPLC-MS/MS. The established method were validated by linearity (r ≥ 0.9990), precision (RSD ≥ 2.9%), average recovery (74.5-105.0%) and limit of detection (0.04-0.10 μg kg(-1)). The developed method is rapid, reliable, sensitive, accurate and has good applicability for real samples.
Pérez-Fernández, Virginia; Marchese, Stefano; Gentili, Alessandra; García, María Ángeles; Curini, Roberta; Caretti, Fulvia; Perret, Daniela
2014-11-07
This paper describes development and validation of a new method for the simultaneous determination of six antithyroid drugs (ATDs) in surface waters by using liquid chromatography-triple quadrupole mass spectrometry (LC-MS/MS). Target compounds include two ATD classes: thiouracil derivatives (thiouracil (TU), methyl-thiouracil (MTU), propyl-thiouracil (PTU), phenyl-thiouracil (PhTU)) and imidazole derivatives (tapazole (TAP), and mercaptobenzimidazole (MBI)). Sensitivity and selectivity of the LC-multiple reaction monitoring (MRM) analysis allowed applying a simple pre-concentration procedure and "shooting" the concentrated sample into the LC-MS/MS system without any other treatment. Recoveries were higher than 75% for all analytes. Intra-day precision and inter-day precision, calculated as relative standard deviation (RSD), were below 19 and 22%, respectively. Limits of detection (LODs) ranged from 0.05 to 0.25 μg/L; limits of quantitation (LOQs) varied between 0.15 and 0.75 μg/L. The validated method was successfully applied to the analysis of ATD residues in surface water samples collected from the Tiber River basin and three lakes of Lazio (central Italy). The analytes were quantified based on matrix-matched calibration curves with mercaptobenzimidazole-d4 (MBI-d4) as the internal standard (IS). The most widespread compound was TAP, one of the most common ATDs used in human medicine, but also TU and MBI were often detected in the analysed samples. Copyright © 2014 Elsevier B.V. All rights reserved.
Sun, Qi-ran; Xiang, Ping; Yan, Hui; Shen, Min
2008-12-01
A sensitive LC-MS/MS method to determine cocaine and its major metabolite benzoylecgonine in guinea pig' s hair has been established. About 20 mg of decontaminated hair sample was hydrolyzed with 0. 1 mol x L(-1) HCl at 50 degrees C overnight, in the presence of cocaine-d3 and benzoylecgonine-d8 used as internal standards, and then extracted with dichlormethane. The analysis was performed by liquid chromatography-tandem mass spectrometry (LC-MS/MS). Positive electrospray ionization (ESI +) and multiple reactions monitoring (MRM) mode were used. The limit of detection (LOD) for cocaine and benzoylecgonine was 1 pg x mg(-1). The calibration curves of extracted standards were linear over the range from 5 pg x mg(-1) to 250 pg x mg(-1) (r2 > or = 0.9997). The method was validated and applied to the analysis of guinea pig's hair after a single dose administration of cocaine hydrochloride. Cocaine and benzoylecgonine were not only detected, but also quantified in guinea pigs hair.
Multiclass determination and confirmation of antibiotic residues in honey using LC-MS/MS.
Lopez, Mayda I; Pettis, Jeffery S; Smith, I Barton; Chu, Pak-Sin
2008-03-12
A multiclass method has been developed for the determination and confirmation in honey of tetracyclines (chlortetracycline, doxycycline, oxytetracycline, and tetracycline), fluoroquinolones (ciprofloxacin, danofloxacin, difloxacin, enrofloxacin, and sarafloxacin), macrolides (tylosin), lincosamides (lincomycin), aminoglycosides (streptomycin), sulfonamides (sulfathiazole), phenicols (chloramphenicol), and fumagillin residues using liquid chromatography tandem mass spectrometry (LC-MS/MS). Erythromycin (a macrolide) and monensin (an ionophore) can be detected and confirmed but not quantitated. Honey samples (approximately 2 g) are dissolved in 10 mL of water and centrifuged. An aliquot of the supernatant is used to determine streptomycin. The remaining supernatant is filtered through a fine-mesh nylon fabric and cleaned up by solid phase extraction. After solvent evaporation and sample reconstitution, 15 antibiotics are assayed by LC-MS/MS using electrospray ionization (ESI) in positive ion mode. Afterward, chloramphenicol is assayed using ESI in negative ion mode. The method has been validated at the low part per billion levels for most of the drugs with accuracies between 65 and 104% and coefficients of variation less than 17%. The evaluation of matrix effects caused by honey of different floral origin is presented.
Tang, Hubert Po-On; Ho, Clare; Lai, Shirley Sau-Ling
2006-01-01
A rapid qualitative method using on-line column-switching liquid chromatography/tandem mass spectrometry (LC/MS/MS) was developed and validated for screening 13 target veterinary drugs: four macrolides - erythromycin A, josamycin (leucomycin A3), kitasamycin (leucomycin A5), and tylosin A; six (fluoro)quinolones - ciprofloxacin, danofloxacin, enrofloxacin, flumequine, oxolinic acid, and sarafloxacin; and lincomycin, virginiamycin M1, and trimethoprim in different animal muscles. Clindamycin, norfloxacin, nalidixic acid, oleandomycin, ormetoprim, and roxithromycin were used as the internal standards. After simple deproteination and analyte extraction of muscle samples using acetonitrile, the supernatant was subjected to on-line cleanup and direct analysis by LC/MS/MS. On-line cleanup with an extraction cartridge packed with hydrophilic-hydrophobic polymer sorbent followed by fast LC using a short C18 column resulted in a total analysis cycle of 6 min for 19 drugs. This screening method considerably reduced the time and the cost for the quantitative and confirmatory analyses. The application of a control point approach was also introduced and explained. Copyright (c) 2006 John Wiley & Sons, Ltd.
Poetzsch, Michael; Steuer, Andrea E; Roemmelt, Andreas T; Baumgartner, Markus R; Kraemer, Thomas
2014-12-02
Single hair analysis normally requires extensive sample preparation microscale protocols including time-consuming steps like segmentation and extraction. Matrix assisted laser desorption and ionization mass spectrometric imaging (MALDI-MSI) was shown to be an alternative tool in single hair analysis, but still, questions remain. Therefore, an investigation of MALDI-MSI in single hair analysis concerning the extraction process, usage of internal standard (IS), and influences on the ionization processes were systematically investigated to enable the reliable application to hair analysis. Furthermore, single dose detection, quantitative correlation to a single hair, and hair strand LC-MS/MS results were performed, and the performance was compared to LC-MS/MS single hair monitoring. The MALDI process was shown to be independent from natural hair color and not influenced by the presence of melanin. Ionization was shown to be reproducible along and in between different hair samples. MALDI image intensities in single hair and hair snippets showed good semiquantitative correlation to zolpidem hair concentrations obtained from validated routine LC-MS/MS methods. MALDI-MSI is superior to LC-MS/MS analysis when a fast, easy, and cheap sample preparation is necessary, whereas LC-MS/MS showed higher sensitivity with the ability of single dose detection for zolpidem. MALDI-MSI and LC-MS/MS segmental single hair analysis showed good correlation, and both are suitable for consumption monitoring of drugs of abuse with a high time resolution.
Kobayashi, Minatsu; Jwa, Seung Chik; Ogawa, Kohei; Morisaki, Naho; Fujiwara, Takeo
2017-01-01
The relative validity of food frequency questionnaires for estimating long-chain polyunsaturated fatty acid (LC-PUFA) intake among pregnant Japanese women is currently unclear. The aim of this study was to verify the external validity of a food frequency questionnaire, originally developed for non-pregnant adults, to assess the dietary intake of LC-PUFA using dietary records and serum phospholipid levels among Japanese women in early and late pregnancy. A validation study involving 188 participants in early pregnancy and 169 participants in late pregnancy was conducted. Intake LC-PUFA was estimated using a food frequency questionnaire and evaluated using a 3-day dietary record and serum phospholipid concentrations in both early and late pregnancy. The food frequency questionnaire provided estimates of eicosapentaenoic acid (EPA) and docosahexaenoic acid (DHA) intake with higher precision than dietary records in both early and late pregnancy. Significant correlations were observed for LC-PUFA intake estimated using dietary records in both early and late pregnancy, particularly for EPA and DHA (correlation coefficients ranged from 0.34 to 0.40, p < 0.0001). Similarly, high correlations for EPA and DHA in serum phospholipid composition were also observed in both early and late pregnancy (correlation coefficients ranged 0.27 to 0.34, p < 0.0001). Our findings suggest that the food frequency questionnaire, which was originally designed for non-pregnant adults and was evaluated in this study against dietary records and biological markers, has good validity for assessing LC-PUFA intake, especially EPA and DHA intake, among Japanese women in early and late pregnancy. Copyright © 2016 The Authors. Production and hosting by Elsevier B.V. All rights reserved.
Napolitano, José G.; Gödecke, Tanja; Lankin, David C.; Jaki, Birgit U.; McAlpine, James B.; Chen, Shao-Nong; Pauli, Guido F.
2013-01-01
The development of analytical methods for parallel characterization of multiple phytoconstituents is essential to advance the quality control of herbal products. While chemical standardization is commonly carried out by targeted analysis using gas or liquid chromatography-based methods, more universal approaches based on quantitative 1H NMR (qHNMR) measurements are being used increasingly in the multi-targeted assessment of these complex mixtures. The present study describes the development of a 1D qHNMR-based method for simultaneous identification and quantification of green tea constituents. This approach utilizes computer-assisted 1H iterative Full Spin Analysis (HiFSA) and enables rapid profiling of seven catechins in commercial green tea extracts. The qHNMR results were cross-validated against quantitative profiles obtained with an orthogonal LC-MS/MS method. The relative strengths and weaknesses of both approaches are discussed, with special emphasis on the role of identical reference standards in qualitative and quantitative analyses. PMID:23870106
RapidRIP quantifies the intracellular metabolome of 7 industrial strains of E. coli.
McCloskey, Douglas; Xu, Julia; Schrübbers, Lars; Christensen, Hanne B; Herrgård, Markus J
2018-04-25
Fast metabolite quantification methods are required for high throughput screening of microbial strains obtained by combinatorial or evolutionary engineering approaches. In this study, a rapid RIP-LC-MS/MS (RapidRIP) method for high-throughput quantitative metabolomics was developed and validated that was capable of quantifying 102 metabolites from central, amino acid, energy, nucleotide, and cofactor metabolism in less than 5 minutes. The method was shown to have comparable sensitivity and resolving capability as compared to a full length RIP-LC-MS/MS method (FullRIP). The RapidRIP method was used to quantify the metabolome of seven industrial strains of E. coli revealing significant differences in glycolytic, pentose phosphate, TCA cycle, amino acid, and energy and cofactor metabolites were found. These differences translated to statistically and biologically significant differences in thermodynamics of biochemical reactions between strains that could have implications when choosing a host for bioprocessing. Copyright © 2018. Published by Elsevier Inc.
Bansal, Gulshan; Singh, Ranjit; Saini, Balraj; Bansal, Yogita
2013-01-01
The present study reports the characterization of forced degradation products of bosentan and a validated stability-indicating HPLC method for the stability testing of bosentan tablets. The forced degradation was carried out under the conditions of hydrolysis, oxidation, dry heat and photolysis. The drug was found unstable in acid, alkali and oxidative media whereas stable to the hydrolysis in water, to dry heat and to photolysis. In total, six degradation products were formed in all conditions which were resolved in a single run on a C-18 column with gradient elution using ammonium acetate buffer (pH 4.5, 5.0mM), methanol and acetonitrile. Structures of all the degradation products were characterized through +ESI-MS(n) and LC-ESI-MS spectral data of bosentan as well as LC-ESI-MS spectral data of the products. The products II-VI were characterized as 6-amino-[2,2']bipyrimidinyl-4,5-diol, 6-amino-5-(2-methoxyphenoxy)-[2,2']-bipyrimidinyl-4-ol, 2-[6-amino-5-(2-methoxyphenoxy)-[2,2']-bipyrimidinyl-4-yloxy]-ethanol, 4-tert-butyl-N-[6-(1-methoxyethoxy)-5-(2-methoxyphenoxy)-[2,2']-bipyrimidinyl-4-yl]-benzenesulfonamide and 4-tert-butyl-N-[6-hydroxy-5-(2-methoxyphenoxy)-[2,2']bipyrimidinyl-4-yl]-benzenesulfonamide, respectively. The peak of the product I was found to be due to two secondary degradation products which co-eluted and were characterized as β-hydroxyethyl p-tert-butylphenylsulfonate (Ia) and 2-[2-(2-hydroxyethoxy)-phenoxy]-ethanol (Ib). These products were formed due to hydrolysis of sulfonamide and alkylaryl ether and the diaryl ether linkages as well as dehydration of the primary alcohol group. The most probable degradation mechanisms were proposed. The HPLC method was found to be stability-indicating, linear (2-100 μg ml(-1)), accurate, precise, sensitive, specific, rugged and robust for quantitation of the drug. The method was applied to the stability testing of the commercially available bosentan tablets successfully. Copyright © 2012 Elsevier B.V. All rights reserved.
Mostafa, Nadia M; Elsayed, Ghada M; Hassan, Nagiba Y; El Mously, Dina A
2017-11-01
Five simple, sensitive, and eco-friendly LC and UV spectrophotometric methods have been developed for the simultaneous determination of phenylephrine hydrochloride (PHE) and prednisolone acetate (PRD) in their combined dosage form. The first method was reversed-phase (RP) LC using methanol-water-heptane-1-sulfonic acid sodium salt (75 + 25 + 0.1, v/v/w) as a mobile phase. Separation was achieved using an XSelect HSS reversed-phase C18 analytical column (250 × 4.6 mm, 5µm). The flow rate was 1.0 mL/min and UV detection was done at 230 nm. Quantification was achieved over the concentration ranges of 5-50 µg/mL for PHE and 2-90 µg/mL for PRD. Four spectrophotometric methods were proposed, namely dual wavelength, first derivative of ratio spectra, ratio difference, and mean-centering of ratio spectra. Linearity was observed in the concentration ranges of 10-120 and 5-35 µg/mL for PHE and PRD, respectively, for the spectrophotometric methods. Green solvents were used in the proposed methods because they play a vital role in the analytical methods' influence on the environment. The suggested methods were validated regarding linearity, accuracy, and precision according to the International Conference on Harmonization guidelines, with satisfactory results. These methods could be used as harmless substitutes for routine analysis of the mentioned drugs, with no interference from excipients.
Jimmerson, Leah C.; Ray, Michelle L.; Bushman, Lane R.; Anderson, Peter L.; Klein, Brandon; Rower, Joseph E.; Zheng, Jia-Hua; Kiser, Jennifer J.
2014-01-01
Ribavirin (RBV) is a nucleoside analog used to treat a variety of DNA and RNA viruses. RBV undergoes intracellular phosphorylation to a mono- (MP), di- (DP), and triphosphate (TP). The phosphorylated forms have been associated with the mechanisms of antiviral effect observed in vitro, but the intracellular pharmacology of the drug has not been well characterized in vivo. A highly sensitive LC-MS/MS method was developed and validated for the determination of intracellular RBV MP, DP, and TP in multiple cell matrix types. For this method, the individual MP, DP, and TP fractions were isolated from lysed intracellular matrix using strong anion exchange solid phase extraction, dephosphorylated to parent RBV, desalted and concentrated and quantified using LC-MS/MS. The method utilized a stable labeled internal standard (RBV-13C5) which facilitated accuracy (% deviation within ±15%) and precision (coefficient of variation of ≤15%). The quantifiable linear range for the assay was 0.50 to 200 pmol/sample. The method was applied to the measurement of RBV MP, DP, and TP in human peripheral blood mononuclear cells (PBMC), red blood cells (RBC), and dried blood spot (DBS) samples obtained from patients taking RBV for the treatment of chronic Hepatitis C virus infection. PMID:25555148
Iwasaki, Motoki; Mukai, Tomomi; Takachi, Ribeka; Ishihara, Junko; Totsuka, Yukari; Tsugane, Shoichiro
2014-08-01
Clarification of the putative etiologic role of heterocyclic aromatic amines (HAAs) in the development of cancer requires a validated assessment tool for dietary HAAs. This study primarily aimed to evaluate the validity of a food frequency questionnaire (FFQ) in estimating HAA intake, using 2-amino-1-methyl-6-phenylimidazo[4,5-b]pyridine (PhIP) level in human hair as the reference method. We first updated analytical methods of PhIP using liquid chromatography-electrospray ionization/tandem mass spectrometry (LC-ESI/MS/MS) and measured 44 fur samples from nine rats from a feeding study as part-verification of the quantitative performance of LC-ESI/MS/MS. We next measured PhIP level in human hair samples from a validation study of the FFQ (n = 65). HAA intake from the FFQ was estimated using information on intake from six fish items and seven meat items and data on HAA content in each food item. Correlation coefficients between PhIP level in human hair and HAA intake from the FFQ were calculated. The animal feeding study of PhIP found a significant dose-response relationship between dosage and PhIP in rat fur. Mean level was 53.8 pg/g hair among subjects with values over the limit of detection (LOD) (n = 57). We found significant positive correlation coefficients between PhIP in human hair and HAA intake from the FFQ, with Spearman rank correlation coefficients of 0.35 for all subjects, 0.21 for subjects with over LOD values, and 0.34 for subjects with over limit of quantification. Findings from the validation study suggest that the FFQ is reasonably valid for the assessment of HAA intake.
Reference Proteome Extracts for Mass Spec Instrument Performance Validation and Method Development
Rosenblatt, Mike; Urh, Marjeta; Saveliev, Sergei
2014-01-01
Biological samples of high complexity are required to test protein mass spec sample preparation procedures and validate mass spec instrument performance. Total cell protein extracts provide the needed sample complexity. However, to be compatible with mass spec applications, such extracts should meet a number of design requirements: compatibility with LC/MS (free of detergents, etc.)high protein integrity (minimal level of protein degradation and non-biological PTMs)compatibility with common sample preparation methods such as proteolysis, PTM enrichment and mass-tag labelingLot-to-lot reproducibility Here we describe total protein extracts from yeast and human cells that meet the above criteria. Two extract formats have been developed: Intact protein extracts with primary use for sample preparation method development and optimizationPre-digested extracts (peptides) with primary use for instrument validation and performance monitoring
Vacondio, Federica; Silva, Claudia; Fioni, Alessandro; Mor, Marco; Rivara, Mirko; Bordi, Fabrizio; Flammini, Lisa; Ballabeni, Vigilio; Barocelli, Elisabetta
2008-01-07
A rapid, simple and sensitive liquid chromatography-mass spectrometry (LC-MS) method was developed and validated for the determination of the imidazole H(3) antagonist ROS203 in rat plasma, using the superior homologue ROS287 as internal standard. Analyses were performed on an Agilent 1100 Series HPLC system employing a Supelco Ascentis C(18) column and isocratic elution with acetonitrile-10mM ammonium acetate buffer pH 4.0 (30:70, v/v) at a flow rate of 0.25 mL/min. An Applied Biosystems/MDS Sciex 150-EX single quadrupole mass spectrometer, equipped with an electrospray ionization interface was employed, operating in the positive ion mode. Plasma samples were deproteinized with acetonitrile (1:2), evaporated under nitrogen stream, reconstituted in the mobile phase and 5 microL were injected into the system. The retention times of ROS203 and IS were 2.20 and 2.90 min, respectively. Calibration curves in spiked plasma were linear over the concentration range of 2610-2.61 ng/mL with determination coefficients >0.99. The lower limit of quantification (LLOQ) was 2.61 ng/mL. The accuracy of the method was within 15%. Intra- and inter-day relative standard deviations were less or equal to 9.50% or 7.19%, respectively. The applicability of the LC-MS method was tested employing plasma samples obtained after i.p. administration of ROS203 to female Wistar rats to support a behavioral in vivo study. The specificity of the method was confirmed by the absence of interferences from endogenous substances. The reported method can provide the necessary sensitivity, linearity, precision, accuracy and specificity to allow the determination of ROS203 in rat plasma samples to support further pharmacokinetic assays.
2014-01-01
Background Yakuchinone A has a plethora of beneficial biological effects. However, the pharmacokinetic (PK) data of yakuchinone A still remain unknown so far. Furthermore, the quantification of yakuchinone A in biological samples has not been reported in the literature. Therefore, in the present study we aimed to develop a new method for the fast, efficient and accurate assessment of yakuchinone A concentration in plasma, as a means for facilitating the PK evaluation of yakuchinone A. Results A liquid chromatography-electrospray ionization-tandem mass spectrometry (LC-ESI-MS/MS) method was developed and validated for the determination of yakuchinone A in rat plasma. Mass spectrometric and chromatographic conditions were optimized. Plasma samples were pretreated by protein precipitation with methanol. LC separation was performed on a Phenomenex Luna C18 column with gradient elution using a mobile phase consisting of methanol–water containing 0.5 mM formic acid (HCOOH) at a flow rate of 0.28 mL/min. ESI-MS spectra were acquired in positive ion multiple reaction monitoring mode (MRM). The precursor-to-product ion pairs used for MRM of yakuchinone A and yakuchinone B were m/z 313.1 → 137.0 and 311.2 → 117.1, respectively. Low concentration of HCOOH reduced the ion suppression caused by matrix components and clearly improved the analytical sensitivity. Yakuchinone A showed good linearity over a wide concentration range (r > 0.99). The accuracy, precision, stability and linearity were found to be within the acceptable criteria. This new method was successfully applied to analyze the rat plasma concentration of parent yakuchinone A after a single oral administration of SuoQuan capsules. Low systemic exposure to parent yakuchinone A was observed. Conclusion The proposed method is sensitive and reliable. It is hoped that this new method will prove useful for the future PK studies. PMID:24422995
Brozmanová, Hana; Kacířová, Ivana; Uřinovská, Romana; Šištík, Pavel; Grundmann, Milan
2017-06-01
A new LC-MS/MS method with simple sample extraction and a relatively short period of vancomycin analysis for routine therapeutic drug monitoring was developed and validated. 50μL serum was precipitated using 20μL 33% trichloroacetic acid and 0.5mol/L NH 4 OH was added to increase pH before analysis. A RP BEH C18, 1.7μm, 2.1×50mm column maintained at 30°C and tobramycin as internal standard were used. Mass detection was performed in positive electrospray mode. The results obtained with LC-MS/MS method were correlated with an FPIA assay (Abbott AxSYM) using mouse monoclonal antibody. Subjects were divided into three groups according to creatinine levels (53.5±19.1, 150.2±48.4, 471.7±124.7μmol/L) and Passing-Bablok regression analysis and Bland-Altman analysis were used to compare vancomycin concentrations. The results of subjects with both normal and higher creatinine levels correlated very well and the linear regression model equations were near ideal (LC-MS VAN =0.947×Abbott VAN +0.192 and LC-MS VAN =0.973×Abbott VAN -0.411 respectively). Dialyzed patients with the highest creatinine levels showed about 14% greater vancomycin concentration with the FPIA assay (LC-MS VAN =0.866×Abbott VAN +2.127). This overestimation probably due to the presence of the metabolite CDP ought not to be of clinical relevance owing to the wide range of recommended vancomycin concentration. Copyright © 2017 Elsevier B.V. All rights reserved.
Jourdil, Jean-François; Némoz, Benjamin; Gautier-Veyret, Elodie; Romero, Charlotte; Stanke-Labesque, Françoise
2018-03-30
Adalimumab (ADA) and infliximab (IFX) are therapeutic monoclonal antibodies (TMabs) targeting tumor necrosis factor-alpha (TNFα). They are used to treat inflammatory diseases. Clinical trials have suggested that therapeutic drug monitoring for ADA or IFX could improve treatment response and cost-effectiveness. However, ADA and IFX were quantified by ELISA in all these studies, and the discrepancies between the results obtained raise questions about their reliability.We describe here the validation of a liquid chromatography-tandem mass spectrometry (LC-MS/MS) method for the simultaneous quantification of ADA and IFX in human samples. Full-length antibodies labeled with stable isotopes were added to plasma samples as an internal standard. Samples were then prepared using Mass Spectrometry Immuno Assay (MSIA) followed by trypsin digestion prior ADA and IFX quantification by LC-MS/MS.ADA and IFX were quantified in serum from patients treated with ADA (n=21) or IFX (n=22), and the concentrations obtained were compared with those obtained with a commercial ELISA kit. The chromatography run lasted 8.6 minutes and the quantification range was 1 to 26 mg/L. The method was reproducible, repeatable and accurate. For both levels of internal quality control, for ADA and IFX inter and intra-day coefficients of variation and accuracies were all within 15%, in accordance with FDA recommendations. No significant cross-contamination effect was noted.Good agreement was found between LC-MS/MS and ELISA results, for both ADA and IFX. This LC-MS/MS method can be used for the quantification of ADA and IFX in a single analytical run and for the optimization of LC-MS/MS resource use in clinical pharmacology laboratories.
Analysis of Ethanolamines: Validation of Semi-Volatile Analysis by HPLC-MS/MS by EPA Method MS888
DOE Office of Scientific and Technical Information (OSTI.GOV)
Owens, J; Vu, A; Koester, C
The Environmental Protection Agency's (EPA) Region 5 Chicago Regional Laboratory (CRL) developed a method titled 'Analysis of Diethanolamine, Triethanolamine, n-Methyldiethanolamine, and n-Ethyldiethanolamine in Water by Single Reaction Monitoring Liquid Chromatography/Tandem Mass Spectrometry (LC/MS/MS): EPA Method MS888'. This draft standard operating procedure (SOP) was distributed to multiple EPA laboratories and to Lawrence Livermore National Laboratory, which was tasked to serve as a reference laboratory for EPA's Environmental Reference Laboratory Network (ERLN) and to develop and validate analytical procedures. The primary objective of this study was to validate and verify the analytical procedures described in 'EPA Method MS888' for analysis of themore » listed ethanolamines in aqueous samples. The gathered data from this validation study will be used to: (1) demonstrate analytical method performance; (2) generate quality control acceptance criteria; and (3) revise the SOP to provide a validated method that would be available for use during a homeland security event. The data contained in this report will be compiled, by EPA CRL, with data generated by other EPA Regional laboratories so that performance metrics of 'EPA Method MS888' can be determined.« less
Broekaert, N; Devreese, M; De Mil, T; Fraeyman, S; De Baere, S; De Saeger, S; De Backer, P; Croubels, S
2014-11-15
This study aims to develop an LC-MS/MS method allowing the determination of 3-acetyl-deoxynivalenol, 15-acetyl-deoxynivalenol, deoxynivalenol and its main in vivo metabolite, deepoxy-deoxynivalenol, in broiler chickens and pigs. These species have a high exposure to these toxins, given their mainly cereal based diet. Several sample cleanup strategies were tested and further optimized by means of fractional factorial designs. A simple and straightforward sample preparation method was developed consisting out of a deproteinisation step with acetonitrile, followed by evaporation of the supernatant and reconstitution in water. The method was single laboratory validated according to European guidelines and found to be applicable for the intended purpose, with a linear response up to 200ngml(-1) and limits of quantification of 0.1-2ngml(-1). As a proof of concept, biological samples from a broiler chicken that received either deoxynivalenol, 3- or 15-acetyl-deoxynivalenol were analyzed. Preliminary results indicate nearly complete hydrolysis of 3-acetyl-deoxynivalenol to deoxynivalenol; and to a lesser extent of 15-acetyl-deoxynivalenol to deoxynivalenol. No deepoxy-deoxynivalenol was detected in any of the plasma samples. The method will be applied to study full toxicokinetic properties of deoxynivalenol, 3-acetyl-deoxynivalenol and 15-acetyl-deoxynivalenol in broiler chickens and pigs. Copyright © 2014 Elsevier B.V. All rights reserved.
Sanghvi, M.; Ramamoorthy, A.; Strait, J.; Wainer, I. W.; Moaddel, R.
2013-01-01
Due to the lack of sensitivity in current methods for the determination of fenoterol (Fen). A rapid, LC-MS/MS method was developed for the determination of (R,R′)-Fen and (R,R′;S,S′)-Fen in plasma and urine. The method was fully validated and was linear from 50 pg/ml to 2000 pg/ml for plasma and from 2.500 ng/ml to 160 ng/ml for urine with a lower limit of quantitation of 52.8 pg/ml in plasma. The coefficient of variation was <15% for the high QC standards and <10% for the low QC standards in plasma and was <15% for the high and low QC standards in urine. The relative concentrations of (R,R′)-Fen and (S,S′)-Fen were determined using a chirobiotic T chiral stationary phase. The method was used to determine the concentration of (R,R′)-Fen in plasma and urine samples obtained in an oral cross-over study of (R,R′)-Fen and (R,R′;S,S′)-Fen formulations. The results demonstrated a potential pre-systemic enantioselective interaction in which the (S,S′)-Fen reduces the sulfation of the active (R,R′)-Fen. The data suggests that a non-racemic mixture of the Fen enantiomers may provide better bioavailability of the active (R,R′)-Fen for use in the treatment of cardiovascular disease PMID:23872161
Quantitation of brinzolamide in dried blood spots by a novel LC-QTOF-MS/MS method.
Foivas, Anargyros; Malenović, Anđelija; Kostić, Nađa; Božić, Marija; Knežević, Miroslav; Loukas, Yannis L; Dotsikas, Yannis
2016-02-05
In the current study, a rapid and sensitive LC-QTOF-MS/MS method for the determination of brinzolamide in dried blood spots (DBS) was developed and validated. This novel sample collection, storage and transfer technique was suitable for analyzing a drug with high distribution into red blood cells and negligible plasma levels. The method included an isocratic mobile phase consisting of methanol and 10mM ammonium formate (90:10, v/v) and detection in positive electrospray mode (ESI+). The flow rate was adjusted to 0.350mL/min yielding retention times of 1.7min for both brinzolamide and internal standard (IS) rabeprazole on a Cyano analytical column, respectively. The validation of the proposed method over the concentration range 0.500-20.0μg/mL was performed in compliance with EMEA and FDA guidelines, assessing all major performance characteristics. Inter- and intra- assay precisions were less than 14%, while inter- and intra- assay accuracies varied from 92.2 to 111%. No matrix effect was observed and the mean brinzolamide extraction recovery was 93.5%. The method was successfully applied to real DBS samples from patients in steady state condition, receiving brinzolamide ophthalmic suspension 1% (w/v) for several months. Initial concentrations were corrected due to hematocrit effect, using image processing algorithm written in Matlab. Copyright © 2015 Elsevier B.V. All rights reserved.
Ens, Waldemar; Senner, Frank; Gygax, Benjamin; Schlotterbeck, Götz
2014-05-01
A new method for the simultaneous determination of iodated X-ray contrast media (ICM) and artificial sweeteners (AS) by liquid chromatography-tandem mass spectrometry (LC-MS/MS) operated in positive and negative ionization switching mode was developed. The method was validated for surface, ground, and drinking water samples. In order to gain higher sensitivities, a 10-fold sample enrichment step using a Genevac EZ-2 plus centrifugal vacuum evaporator that provided excellent recoveries (90 ± 6 %) was selected for sample preparation. Limits of quantification below 10 ng/L were obtained for all compounds. Furthermore, sample preparation recoveries and matrix effects were investigated thoroughly for all matrix types. Considerable matrix effects were observed in surface water and could be compensated by the use of four stable isotope-labeled internal standards. Due to their persistence, fractions of diatrizoic acid, iopamidol, and acesulfame could pass the whole drinking water production process and were observed also in drinking water. To monitor the fate and occurrence of these compounds, the validated method was applied to samples from different stages of the drinking water production process of the Industrial Works of Basel (IWB). Diatrizoic acid was found as the most persistent compound which was eliminated by just 40 % during the whole drinking water treatment process, followed by iopamidol (80 % elimination) and acesulfame (85 % elimination). All other compounds were completely restrained and/or degraded by the soil and thus were not detected in groundwater. Additionally, a direct injection method without sample preparation achieving 3-20 ng/L limits of quantification was compared to the developed method.
Zweigenbaum, J; Henion, J
2000-06-01
The high-throughput determination of small molecules in biological matrixes has become an important part of drug discovery. This work shows that increased throughput LC/MS/MS techniques can be used for the analysis of selected estrogen receptor modulators in human plasma where more than 2000 samples may be analyzed in a 24-h period. The compounds used to demonstrate the high-throughput methodology include tamoxifen, raloxifene, 4-hydroxytamoxifen, nafoxidine, and idoxifene. Tamoxifen and raloxifene are used in both breast cancer therapy and osteoporosis and have shown prophylactic potential for the reduction of the risk of breast cancer. The described strategy provides LC/MS/MS separation and quantitation for each of the five test articles in control human plasma. The method includes sample preparation employing liquid-liquid extraction in the 96-well format, an LC separation of the five compounds in less than 30 s, and selected reaction monitoring detection from low nano- to microgram per milliter levels. Precision and accuracy are determined where each 96-well plate is considered a typical "tray" having calibration standards and quality control (QC) samples dispersed through each plate. A concept is introduced where 24 96-well plates analyzed in 1 day is considered a "grand tray", and the method is cross-validated with standards placed only at the beginning of the first plate and the end of the last plate. Using idoxifene-d5 as an internal standard, the results obtained for idoxifene and tamoxifen satisfy current bioanalytical method validation criteria on two separate days where 2112 and 2304 samples were run, respectively. Method validation included 24-h autosampler stability and one freeze-thaw cycle stability for the extracts. Idoxifene showed acceptable results with accuracy ranging from 0.3% for the high quality control (QC) to 15.4% for the low QC and precision of 3.6%-13.9% relative standard deviation. Tamoxifen showed accuracy ranging from 1.6% to 13.8% and precision from 7.8% to 15.2%. The linear dynamic range for these compounds was 3 orders of magnitude. The limit of quantification was 5 and 50 ng/ mL for tamoxifen and idoxifene, respectively. The other compounds in this study in general satisfy the more relaxed bioanalytical acceptance criteria for modern drug discovery. It is suggested that the quantification levels reported in this high-throughput analysis example are adequate for many drug discovery and related early pharmaceutical studies.
Lucentini, Luca; Ferretti, Emanuele; Veschetti, Enrico; Achene, Laura; Turrio-Baldassarri, Luigi; Ottaviani, Massimo; Bogialli, Sara
2009-01-01
A simple and sensitive liquid chromatographic-tandem mass spectrometric (LC/MS/MS) method has been developed and validated to confirm and quantify acrylamide monomer (AA) in drinking water using [13C3] acrylamide as internal standard (IS). After a preconcentration by solid-phase extraction with spherical activated carbon, analytes were chromatographed on IonPac ICE-AS1 column (9 x 250 mm) under isocratic conditions using acetonitrile-water-0.1 M formic acid (43 + 52 + 5, v/v/v) as the mobile phase. Analysis was achieved using a triple-quadrupole mass analyzer equipped with a turbo ion spray interface. For confirmation and quantification of the analytes, MS data acquisition was performed in the multireaction monitoring mode, selecting 2 precursor ion to product ion transitions for both AA and IS. The method was validated for linearity, sensitivity, accuracy, precision, extraction efficiency, and matrix effect. Linearity in tap water was observed over the concentration range 0.1-2.0 microg/L. Limits of detection and quantification were 0.02 and 0.1 microg/L, respectively. Interday and intraday assays were performed across 3 validation levels (0.1, 0.5, and 1.5 microg/L). Accuracy (as mean recovery) ranged from 89.3 to 96.2% with relative standard deviation <7.98%. Performance characteristics of this LC/MS/MS method make it suitable for regulatory confirmatory analysis of AA in drinking water in compliance with European Union and U.S. Environmental Protection Agency standards.
Ma, Hongda; Wang, Yongjun; Guo, Tao; He, Zhonggui; Chang, Xinyu; Pu, Xiaohui
2009-02-20
A sensitive and specific liquid chromatography-electrospray ionization-mass spectrometry (LC-ESI-MS) method has been developed and validated for the simultaneous quantification of tetrahydropalmatine, protopine and palmatine in rat plasma using phenacetin as the internal standard (IS). Two hundred microliters plasma samples were extracted by dichloromethane under a strong basic condition. The analytes were separated by a C18 column and detected with a single quadrupole mass spectrometer. The used mobile phase was acetonitrile-water (40:60, v/v) containing 5mM ammonium acetate and 0.2% glacial acetic acid. Detection was carried out by positive electrospray ionization in selected ion reaction (SIR) mode at m/z 356.6 for tetrahydropalmatine, 354.6 for protopine, 352.6 for palmatine and 180.4 for the IS, respectively. The method was validated over the concentration range of 1.00-500ngmL(-1) and the lower limit of quantification (LLOQ) was 1.00ngmL(-1) for all three analytes. The intra- and inter-day precision values were less than 9% relative standard deviation (R.S.D.), and the relative error ranged from -7.4 to 4.8%. The extraction recoveries were on average 91.42% for tetrahydropalmatine, 84.75% for protopine, 57.26% for palmatine, and 83.18% for IS. The validated method was successfully applied to a pharmacokinetic study of tetrahydropalmatine, protopine and palmatine in rats after oral administration of Rhizoma Corydalis Decumbentis extract.
Ferreyra, Carola F; Ortiz, Cristina S
2005-01-01
The aim of this research was to develop and validate a sensitive, rapid, easy, and precise reversed-phase liquid chromatography (LC) method for stability studies of bifonazole (I) formulated with tinctures of calendula flower (II). The method was especially developed for the analysis and quantitative determination of I and II in pure and combined forms in cream pharmaceutical formulations without using gradient elution and at room temperature. The influence on the stability of compound I of temperature, artificial radiation, and drug II used for the new pharmaceutical design was evaluated. The LC separation was carried out using a Supelcosil LC-18 column (25 cm x 4.6 mm id, 5 microm particle size); the mobile phase was composed of methanol-0.1 M ammonium acetate buffer (85 + 15, v/v) pumped isocratically at a flow rate of 1 mL/min; and ultraviolet detection was at 254 nm. The analysis time was less than 10 min. Calibration graphs were found to be linear in the 0.125-0.375 mg/mL (rI = 0.9991) and 0.639-1.916 mg/mL (rII = 0.9995) ranges for I and II, respectively. The linearity, precision, recovery, and limits of detection and quantification were satisfactory for I and II. The results obtained suggested that the developed LC method is selective and specific for the analysis of I and II in pharmaceutical products, and that it can be applied to stability studies.
Paoloni, Angela; Solfrizzo, Michele; Bibi, Rita; Pecorelli, Ivan
2018-05-04
The objective of this study was to develop a liquid chromatography tandem mass spectrometry (LC-MS/MS) method for the determination of Ochratoxin A (OTA) and Ochratoxin α (OTα) in poultry tissues and eggs. The two toxins were extracted by a mixture of acetonitrile/water, purified with a reversed phase C18 solid phase extraction column (SPE) and determined by LC-MS/MS. The LC-MS/MS method performances were evaluated in terms of linearity in solvent and in matrix (ranged from 0.5 to 15.10 µg L -1 for OTA and from 0.60 to 17.85 µg L -1 for OTα), limit of detection (LOD), limit of quantitation (LOQ), specificity, accuracy and precision in repeatability conditions. Recovery experiments were performed by spiking poultry liver, kidney, muscle and eggs around 1 µg kg -1 and 10 µg kg -1 . LODs were 0.27 and 0.26 µg kg -1 while LOQs were fixed at 1.0 and 1.2 µg kg -1 for OTA and OTα, respectively. Main recoveries for OTA ranged from 82 to 109% and for OTα ranged from 55 to 89%. The values of within-laboratory relative standard deviation (RSD r ) were equal to or below 20%. Considering the results obtained and that all analytical performance criteria were fulfilled, the new extraction and purification method developed for OTA and OTα determination in animal tissues and eggs was found appropriate for control laboratories and research activities designed to ensure food safety.
Optimized approaches for quantification of drug transporters in tissues and cells by MRM proteomics.
Prasad, Bhagwat; Unadkat, Jashvant D
2014-07-01
Drug transporter expression in tissues (in vivo) usually differs from that in cell lines used to measure transporter activity (in vitro). Therefore, quantification of transporter expression in tissues and cell lines is important to develop scaling factor for in vitro to in vivo extrapolation (IVIVE) of transporter-mediated drug disposition. Since traditional immunoquantification methods are semiquantitative, targeted proteomics is now emerging as a superior method to quantify proteins, including membrane transporters. This superiority is derived from the selectivity, precision, accuracy, and speed of analysis by liquid chromatography tandem mass spectrometry (LC-MS/MS) in multiple reaction monitoring (MRM) mode. Moreover, LC-MS/MS proteomics has broader applicability because it does not require selective antibodies for individual proteins. There are a number of recent research and review papers that discuss the use of LC-MS/MS for transporter quantification. Here, we have compiled from the literature various elements of MRM proteomics to provide a comprehensive systematic strategy to quantify drug transporters. This review emphasizes practical aspects and challenges in surrogate peptide selection, peptide qualification, peptide synthesis and characterization, membrane protein isolation, protein digestion, sample preparation, LC-MS/MS parameter optimization, method validation, and sample analysis. In particular, bioinformatic tools used in method development and sample analysis are discussed in detail. Various pre-analytical and analytical sources of variability that should be considered during transporter quantification are highlighted. All these steps are illustrated using P-glycoprotein (P-gp) as a case example. Greater use of quantitative transporter proteomics will lead to a better understanding of the role of drug transporters in drug disposition.
Bajerski, Lisiane; Rossi, Rochele Cassanta; Dias, Carolina Lupi; Bergold, Ana Maria; Fröehlich, Pedro Eduardo
2010-06-01
A dissolution test for tablets containing 40 mg of olmesartan medoxomil (OLM) was developed and validated using both LC-UV and UV methods. After evaluation of the sink condition, dissolution medium, and stability of the drug, the method was validated using USP apparatus 2, 50 rpm rotation speed, and 900 ml of deaerated H(2)O + 0.5% sodium lauryl sulfate (w/v) at pH 6.8 (adjusted with 18% phosphoric acid) as the dissolution medium. The model-independent method using difference factor (f(1)) and similarity factor (f(2)), model-dependent method, and dissolution efficiency were employed to compare dissolution profiles. The kinetic parameters of drug release were also investigated. The obtained results provided adequate dissolution profiles. The developed dissolution test was validated according to international guidelines. Since there is no monograph for this drug in tablets, the dissolution method presented here can be used as a quality control test for OLM in this dosage form, especially in a batch to batch evaluation.
Roberts, Michael S; Turner, David C; Owens, Thandranese S; Ramachandran, Abhijit; Wetmore, Cynthia; Throm, Stacy L; Stewart, Clinton F
2013-06-15
A LC-ESI-MS/MS method for the determination of crenolanib (CP-868,596) in human serum was developed and validated employing d4-CP-868,596 as an internal standard (ISTD). In addition to human serum, the method was also partially validated for crenolanib determination in human cerebrospinal fluid (CSF) samples. Sample aliquots (50μl of serum or CSF) were prepared for analysis using liquid-liquid extraction (LLE) with tert-butyl methyl ether. Chromatography was performed using a phenomenex Gemini C18 column (3μm, 100mm×4.6mm I.D.) in a column heater set at 50°C and an isocratic mobile phase (methanol/water/formic acid at a volume ratio of 25/25/0.15, v/v/v). The flow rate was 0.45mL/min, and the retention time for both analyte and ISTD was less than 3.5min. Samples were analyzed with an API-5500 LC-MS/MS system (ESI) in positive ionization mode coupled to a Shimadzu HPLC system. The ion transitions monitored were m/z 444.4→373.1 and m/z 448.2→374.2 for crenolanib and ISTD, respectively. The method was linear over the range of 5-1000ng/mL for serum and 0.5-1000ng/mL for CSF. For human serum, both intra-day and inter-day precision were <4%, while intra-day and inter-day accuracy were within 8% of nominal values. Recovery was greater than 50% for both the analyte and ISTD. For CSF samples, both intra-day and inter-day precision were <9% except at the lower limit of quantification (LLOQ) which was <17%. The intra-day and inter-day accuracy were within 11% of the nominal CSF concentrations. After validation, this method was successfully applied to the analysis of serial pharmacokinetic samples obtained from a child treated with oral crenolanib. Copyright © 2013 Elsevier B.V. All rights reserved.
Direct analysis of [6,6-(2)H2]glucose and [U-(13)C6]glucose dry blood spot enrichments by LC-MS/MS.
Coelho, Margarida; Mendes, Vera M; Lima, Inês S; Martins, Fátima O; Fernandes, Ana B; Macedo, M Paula; Jones, John G; Manadas, Bruno
2016-06-01
A liquid chromatography tandem mass spectrometry (LC-MS/MS) using multiple reaction monitoring (MRM) in a triple-quadrupole scan mode was developed and comprehensively validated for the determination of [6,6-(2)H2]glucose and [U-(13)C6]glucose enrichments from dried blood spots (DBS) without prior derivatization. The method is demonstrated with dried blood spots obtained from rats administered with a primed-constant infusion of [U-(13)C6]glucose and an oral glucose load enriched with [6,6-(2)H2]glucose. The sensitivity is sufficient for analysis of the equivalent to <5μL of blood and the overall method was accurate and precise for the determination of DBS isotopic enrichments. Copyright © 2016 Elsevier B.V. All rights reserved.
2012-01-01
Naturally occurring native peptides provide important information about physiological states of an organism and its changes in disease conditions but protocols and methods for assessing their abundance are not well-developed. In this paper, we describe a simple procedure for the quantification of non-tryptic peptides in body fluids. The workflow includes an enrichment step followed by two-dimensional fractionation of native peptides and MS/MS data management facilitating the design and validation of LC- MRM MS assays. The added value of the workflow is demonstrated in the development of a triplex LC-MRM MS assay used for quantification of peptides potentially associated with the progression of liver disease to hepatocellular carcinoma. PMID:22304756
Marmet, Cynthia; Actis-Goretta, Lucas; Renouf, Mathieu; Giuffrida, Francesca
2014-01-01
Chlorogenic acids and derivatives like phenolic acids are potentially bioactive phenolics, which are commonly found in many foods. Once absorbed, chlorogenic and phenolic acids are highly metabolized by the intestine and the liver, producing glucuronidated and/or sulphated compounds. These metabolites were analyzed in human plasma using a validated liquid chromatography-electrospray ionization-tandem mass spectrometry (LC-ESI-MS/MS) method. After protein precipitation, phenolic acids and their metabolites were extracted by using ethanol and chromatographic separation was achieved by reversed-phase using an Acquity UPLC BEH C18 column combined with a gradient elution system using 1% acetic acid aqueous solution and 1% acetic acid with 100% acetonitrile. The method was able to quantify 56 different compounds including 24 phenolic acids, 4 lactones, 15 sulfates and 13 glucuronides metabolites between 5 and 1000nM in plasma for most of them, except for m-dihydrocoumaric acid, 5-ferulloylquinic-glucuronide, 4-methoxycinnamic acid, 3-phenylpropionic acid, 3-(4-methoxyphenyl)propionic acid (25 to 1000nM) and p-dihydrocoumaric acid (50-1000nM). Values of repeatability and intermediate reproducibility were below 15% of deviation in general, and maximum 20% for the lowest concentrations. The validated method was successfully applied to quantify phenolic acids and their metabolites in plasma obtained after oral ingestion of soluble coffee. In conclusion, the developed and validated method is proved to be very sensitive, accurate and precise for the quantification of these possible dietary phenols. Copyright © 2013 Elsevier B.V. All rights reserved.
Kostić, Nađa; Dotsikas, Yannis; Jović, Nebojša; Stevanović, Galina; Malenović, Anđelija; Medenica, Mirjana
2015-05-10
In this paper, novel LC-MS/MS methods for the determination of antiepileptic drug pregabalin in dried matrix spots (DMS) are presented. This attractive technique of sample collection in micro amount was utilized in the form of dried blood spots (DBS) and dried plasma spots (DPS). Following a pre-column derivatization procedure, using n-propyl chloroformate in the presence of n-propanol, and consecutive liquid-liquid extraction, derivatized pregabalin and its internal standard, 4-aminocyclohexanecarboxylic acid, were detected in positive ion mode by applying two SRM transitions per analyte. A YMC-Pack Octyl column (50mm×4.0mm, 3μm particle size) maintained at 30°C, was utilized with running mobile phase composed of acetonitrile: 0.15% formic acid (85:15, v/v). Flow rate was 550μL/min and total run time 2min. Established methods were fully validated over the concentration range of 0.200-20.0μg/mL for DBS and 0.400-40.0μg/mL for DPS, respectively, while specificity, accuracy, precision, recovery, matrix-effect, stability, dilution integrity and spot homogeneity were found within acceptance criteria. Validated methods were applied for the determination of pregabalin levels in dried blood and plasma samples obtained from patients with epilepsy, after per os administration of commercial capsules. Comparison of drug level in blood and plasma, as well as correction steps undertaken in order to overcome hematocrit issue, when analyzing DBS, are also given. Copyright © 2015 Elsevier B.V. All rights reserved.
Yang, Guangjie; Zhang, Fangrong; Deng, Linfang; Chen, Chang; Cheng, Zhongzhe; Huang, Jiangeng; Liu, Jiangyun; Jiang, Hongliang
2016-09-01
Mucuna pruriens, an ancient Indian herbal medicine containing levodopa, is widely used for Parkinson's disease. In order to simultaneously determine levodopa and 1,1-dimethyl-3-carboxy-6,7-dihydroxy-1,2,3,4-tetrahydroisoquinoline (MD01) in rat plasma, an improved LC-MS/MS method was developed and validated for a pharmacokinetic study in rats orally administered levodopa or Mucuna pruriens extract (MPE). Elimination of matrix effect and improvement of extraction recovery were achieved through systematic optimization of reversed-phase and hydrophilic interaction chromatographic conditions together with sample clean-up procedures. A satisfactory chromatographic performance was obtained with a Thermo Aquasil C18 column (50 × 2.1 mm, 3 µm) using acetonitrile and water containing 0.2% formic acid as mobile phases. Futhermore, sodium metabisulfite and formic acid were used as stabilizers in neat solutions as well as rat plasma. The method was validated in a dynamic range of 20.0-10,000 ng/mL for levodopa and MD01; the intra- and inter-day precision and accuracy were acceptable. The method was successfully utilized to determine the levodopa level in plasma samples of rats administered levodopa or MPE. Pharmacokinetic results showed that an increase in the AUC of levodopa was observed in rats following oral administration of multiple doses of MPE. Copyright © 2016 John Wiley & Sons, Ltd. Copyright © 2016 John Wiley & Sons, Ltd.
Filgueira, Gabriela Campos de Oliveira; Filgueira, Osmany Alberto Silva; Carvalho, Daniela Miarelli; Marques, Maria Paula; Moisés, Elaine Christine Dantas; Duarte, Geraldo; Lanchote, Vera Lucia; Cavalli, Ricardo Carvalho
2015-07-01
Nifedipine is a dihydropyridine calcium channel blocker used for the treatment of hypertension in pregnant women. A liquid chromatography-tandem mass spectrometry (LC-MS/MS) method was developed and validated for analysis of nifedipine in human plasma and amniotic fluid. Separation of nifedipine and nitrendipine (IS) was performed using a LiChroCART(®) RP-Select B column and a mixture of water:acetonitrile:glacial acetic acid (30:70:0.5 v/v) as the mobile phase. Aliquots of 500μL of biological samples were extracted at pH 13 using dichloromethane:n-pentane (3:7 v/v). The validated method was applied to a study of the pharmacokinetics of nifedipine in human plasma and amniotic fluid samples collected up to 12h after administration of the last slow-release nifedipine (20mg/12h) dose to 12 hypertensive pregnant women. The estimated pharmacokinetic parameters of nifedipine showed a mean AUC(0-12) of 250.2ngh/mL, ClT/F of 89.2L/h, Vd/F of 600.0L and t1/2 5.1h. The mean amniotic fluid/plasma concentration ratio was 0.05. The methods proved to be highly sensitive by showing a lower quantification limit of 0.1ng/mL for both matrices. And this study reports for the first time the complete development and validation of the method to quantify nifedipine in amniotic fluid using LC-MS-MS. Copyright © 2015 Elsevier B.V. All rights reserved.
Granja, Rodrigo H M M; Nino, Alfredo M M; Reche, Karine V G; Giannotti, Fabio M; de Lima, Andreia C; Wanschel, Amarylis C B A; Salerno, Alessandro G
2013-01-01
Nitroimidazoles are a class of veterinary drugs used for the treatment and prevention of certain bacterial and protozoal diseases in poultry, swine dysentery and genital trichomoniasis in cattle. Since the safety assessment of nitroimidazoles showed them to be genotoxic, carcinogenic and mutagenic, a number of nitroimidazoles have been banned for therapeutic purposes in different countries. Moreover, nitroimidazoles have also been extensively used as growth promoters in food-producing animals. Due to their efficacious improvement in meat production and feed conversion, deliberate use still exists. Therefore, the illegal use of nitroimidazoles in animal husbandry must be monitored. A sensitive method based on LC-MS/MS for the simultaneous determination and confirmation of five banned nitroimidazole drugs including metronidazole, ronidazole, dimetridazole, metronidazole-OH (metabolite of metronidazole), and 2-hydroxymethyl-1-methyl-5-nitroimidazole (metabolite of ronidazole and dimetridazole) in bovine muscle, using ronidazole-d3 as an internal standard, was developed and validated. After extraction with ethyl acetate and evaporation, the nitroimidazoles were reconstituted in petroleum ether and purified, and LC-MS/MS analysis was performed. The method was validated according to Brazilian Regulation 24/2009 (equivalent to European Union Decision 2002/657/EC). Parameters such as decision limit (CCα), detection capability (CCβ), precision, accuracy, uncertaincy and ruggedness were determined. Average accuracy of the five nitroimidazoles from bovine muscle fortified at 5 levels (0.5, 1.0, 1.5, 2.0 and 2.5 μg kg(-1)) ranged from 96% to 103%. The calculated CCα ranged from 0.0 to 0.17 μg kg(-1); CCβ ranged from 0.08 to 0.41 μg kg(-1). A complete statistical analysis was performed and the results indicate that the method is robust when subjected to day-to-day analytical variations.
Boix, C; Ibáñez, M; Fabregat-Safont, D; Morales, E; Pastor, L; Sancho, J V; Sánchez-Ramírez, J E; Hernández, F
2016-01-01
In this work, two analytical methodologies based on liquid chromatography coupled to tandem mass spectrometry (LC-MS/MS) were developed for quantification of emerging pollutants identified in sewage sludge after a previous wide-scope screening. The target list included 13 emerging contaminants (EC): thiabendazole, acesulfame, fenofibric acid, valsartan, irbesartan, salicylic acid, diclofenac, carbamazepine, 4-aminoantipyrine (4-AA), 4-acetyl aminoantipyrine (4-AAA), 4-formyl aminoantipyrine (4-FAA), venlafaxine and benzoylecgonine. The aqueous and solid phases of the sewage sludge were analyzed making use of Solid-Phase Extraction (SPE) and UltraSonic Extraction (USE) for sample treatment, respectively. The methods were validated at three concentration levels: 0.2, 2 and 20 μg L(-1) for the aqueous phase, and 50, 500 and 2000 μg kg(-1) for the solid phase of the sludge. In general, the method was satisfactorily validated, showing good recoveries (70-120%) and precision (RSD < 20%). Regarding the limit of quantification (LOQ), it was below 0.1 μg L(-1) in the aqueous phase and below 50 μg kg(-1) in the solid phase for the majority of the analytes. The method applicability was tested by analysis of samples from a wider study on degradation of emerging pollutants in sewage sludge under anaerobic digestion. The key benefits of these methodologies are: • SPE and USE are appropriate sample procedures to extract selected emerging contaminants from the aqueous phase of the sewage sludge and the solid residue. • LC-MS/MS is highly suitable for determining emerging contaminants in both sludge phases. • Up to our knowledge, the main metabolites of dipyrone had not been studied before in sewage sludge.
Jenkinson, Carl; Taylor, Angela E; Hassan-Smith, Zaki K; Adams, John S; Stewart, Paul M; Hewison, Martin; Keevil, Brian G
2016-03-01
Recent studies suggest that vitamin D-deficiency is linked to increased risk of common human health problems. To define vitamin D 'status' most routine analytical methods quantify one particular vitamin D metabolite, 25-hydroxyvitamin D3 (25OHD3). However, vitamin D is characterized by complex metabolic pathways, and simultaneous measurement of multiple vitamin D metabolites may provide a more accurate interpretation of vitamin D status. To address this we developed a high-throughput liquid chromatography-tandem mass spectrometry (LC-MS/MS) method to analyse multiple vitamin D analytes, with particular emphasis on the separation of epimer metabolites. A supportive liquid-liquid extraction (SLE) and LC-MS/MS method was developed to quantify 10 vitamin D metabolites as well as separation of an interfering 7α-hydroxy-4-cholesten-3-one (7αC4) isobar (precursor of bile acid), and validated by analysis of human serum samples. In a cohort of 116 healthy subjects, circulating concentrations of 25-hydroxyvitamin D3 (25OHD3), 3-epi-25-hydroxyvitamin D3 (3-epi-25OHD3), 24,25-dihydroxyvitamin D3 (24R,25(OH)2D3), 1,25-dihydroxyvitamin D3 (1α,25(OH)2D3), and 25-hydroxyvitamin D2 (25OHD2) were quantifiable using 220μL of serum, with 25OHD3 and 24R,25(OH)2D3 showing significant seasonal variations. This high-throughput LC-MS/MS method provides a novel strategy for assessing the impact of vitamin D on human health and disease. Copyright © 2016 Elsevier B.V. All rights reserved.
Agger, Sean A.; Marney, Luke C.; Hoofnagle, Andrew N.
2011-01-01
BACKGROUND If liquid-chromatography–multiple-reaction–monitoring mass spectrometry (LC-MRM/MS) could be used in the large-scale preclinical verification of putative biomarkers, it would obviate the need for the development of expensive immunoassays. In addition, the translation of novel biomarkers to clinical use would be accelerated if the assays used in preclinical studies were the same as those used in the clinical laboratory. To validate this approach, we developed a multiplexed assay for the quantification of 2 clinically well-known biomarkers in human plasma, apolipoprotein A-I and apolipoprotein B (apoA-I and apoB). METHODS We used PeptideAtlas to identify candidate peptides. Human samples were denatured with urea or trifluoroethanol, reduced and alkylated, and digested with trypsin. We compared reversed-phase chromatographic separation of peptides with normal flow and microflow, and we normalized endogenous peptide peak areas to internal standard peptides. We evaluated different methods of calibration and compared the final method with a nephelometric immunoassay. RESULTS We developed a final method using trifluoroethanol denaturation, 21-h digestion, normal flow chromatography-electrospray ionization, and calibration with a single normal human plasma sample. For samples injected in duplicate, the method had intraassay CVs <6% and interassay CVs <12% for both proteins, and compared well with immunoassay (n = 47; Deming regression, LC-MRM/MS = 1.17 × immunoassay – 36.6; Sx|y = 10.3 for apoA-I and LC-MRM/MS = 1.21 × immunoassay + 7.0; Sx|y = 7.9 for apoB). CONCLUSIONS Multiplexed quantification of proteins in human plasma/serum by LC-MRM/MS is possible and compares well with clinically useful immunoassays. The potential application of single-point calibration to large clinical studies could simplify efforts to reduce day-to-day digestion variability. PMID:20923952
Turner, Andrew D; Waack, Julia; Lewis, Adam; Edwards, Christine; Lawton, Linda
2018-02-01
A simple, rapid UHPLC-MS/MS method has been developed and optimised for the quantitation of microcystins and nodularin in wide variety of sample matrices. Microcystin analogues targeted were MC-LR, MC-RR, MC-LA, MC-LY, MC-LF, LC-LW, MC-YR, MC-WR, [Asp3] MC-LR, [Dha7] MC-LR, MC-HilR and MC-HtyR. Optimisation studies were conducted to develop a simple, quick and efficient extraction protocol without the need for complex pre-analysis concentration procedures, together with a rapid sub 5min chromatographic separation of toxins in shellfish and algal supplement tablet powders, as well as water and cyanobacterial bloom samples. Validation studies were undertaken on each matrix-analyte combination to the full method performance characteristics following international guidelines. The method was found to be specific and linear over the full calibration range. Method sensitivity in terms of limits of detection, quantitation and reporting were found to be significantly improved in comparison to LC-UV methods and applicable to the analysis of each of the four matrices. Overall, acceptable recoveries were determined for each of the matrices studied, with associated precision and within-laboratory reproducibility well within expected guidance limits. Results from the formalised ruggedness analysis of all available cyanotoxins, showed that the method was robust for all parameters investigated. The results presented here show that the optimised LC-MS/MS method for cyanotoxins is fit for the purpose of detection and quantitation of a range of microcystins and nodularin in shellfish, algal supplement tablet powder, water and cyanobacteria. The method provides a valuable early warning tool for the rapid, routine extraction and analysis of natural waters, cyanobacterial blooms, algal powders, food supplements and shellfish tissues, enabling monitoring labs to supplement traditional microscopy techniques and report toxicity results within a short timeframe of sample receipt. The new method, now accredited to ISO17025 standard, is simple, quick, applicable to multiple matrices and is highly suitable for use as a routine, high-throughout, fast turnaround regulatory monitoring tool. Copyright © 2017 Elsevier B.V. All rights reserved.
Liu, Huaming; Zhang, Dandan; Tang, Zhidan; Sun, Mengjie; Azietaku, John Teye; Ouyang, Huizi; Chang, Yanxu; Wang, Meng; He, Jun; Gao, Xiumei
2018-05-29
Periplocin is a cardiac glycoside and has been used widely in the clinic for its cardiotonic, anti-inflammatory and anti-tumor effects. Though it was taken frequently by oral administration in clinic, there were no reports demonstrated that periplocin could be detected in vivo after an oral administration of periplocin, so it is badly need of searching the characteristic of periplocin in vivo after an oral administration. In this study, a sensitive and reliable liquid chromatography-tandem mass spectrometry (LC-MS/MS) method was developed and validated to identify and quantify periplocin and its two metabolites in rat tissue after a single dosage of perplocin at 50 mg/kg. The results demonstrated that periplocin and its two metabolites were detected in all of the selected tissues, periplocin could be reach peak concentration quickly after administration, while periplocymarin and periplogenin reached maximum concentration more than 4.83 h after administration. The tissue distribution of analytes tended to be mostly in the liver, and higher analytes concentrations were found in the heart, liver, spleen, lung, kidney, but a small amount of chemical constituents were distributed into the brain. The consequences obtained using this method might provide a meaningful insight for the clinical investigations and applications. This article is protected by copyright. All rights reserved.
Heinig, Katja; Miya, Kazuhiro; Kamei, Tomonori; Guerini, Elena; Fraier, Daniela; Yu, Li; Bansal, Surendra; Morcos, Peter N
2016-07-01
Alectinib is a novel anaplastic lymphoma kinase (ALK) inhibitor for treatment of patients with ALK-positive non-small-cell lung cancer who have progressed on or are intolerant to crizotinib. To support clinical development, concentrations of alectinib and metabolite M4 were determined in plasma from patients and healthy subjects. LC-MS/MS methods were developed and validated in two different laboratories: Chugai used separate assays for alectinib and M4 in a pivotal Phase I/II study while Roche established a simultaneous assay for both analytes for another pivotal study and all other studies. Cross-validation assessment revealed a bias between the two bioanalytical laboratories, which was confirmed with the clinical PK data between both pivotal studies using the different bioanalytical methods.
Gaudin, Valérie
2017-09-01
Screening methods are used as a first-line approach to detect the presence of antibiotic residues in food of animal origin. The validation process guarantees that the method is fit-for-purpose, suited to regulatory requirements, and provides evidence of its performance. This article is focused on intra-laboratory validation. The first step in validation is characterisation of performance, and the second step is the validation itself with regard to pre-established criteria. The validation approaches can be absolute (a single method) or relative (comparison of methods), overall (combination of several characteristics in one) or criterion-by-criterion. Various approaches to validation, in the form of regulations, guidelines or standards, are presented and discussed to draw conclusions on their potential application for different residue screening methods, and to determine whether or not they reach the same conclusions. The approach by comparison of methods is not suitable for screening methods for antibiotic residues. The overall approaches, such as probability of detection (POD) and accuracy profile, are increasingly used in other fields of application. They may be of interest for screening methods for antibiotic residues. Finally, the criterion-by-criterion approach (Decision 2002/657/EC and of European guideline for the validation of screening methods), usually applied to the screening methods for antibiotic residues, introduced a major characteristic and an improvement in the validation, i.e. the detection capability (CCβ). In conclusion, screening methods are constantly evolving, thanks to the development of new biosensors or liquid chromatography coupled to tandem-mass spectrometry (LC-MS/MS) methods. There have been clear changes in validation approaches these last 20 years. Continued progress is required and perspectives for future development of guidelines, regulations and standards for validation are presented here.
Applications of LC-MS in PET Radioligand Development and Metabolic Elucidation
Ma, Ying; Kiesewetter, Dale O.; Lang, Lixin; Gu, Dongyu; Chen, Xiaoyuan
2013-01-01
Positron emission tomography (PET) is a very sensitive molecular imaging technique that when employed with an appropriate radioligand has the ability to quantititate physiological processes in a non-invasive manner. Since the imaging technique detects all radioactive emissions in the field of view, the presence and biological activity of radiolabeled metabolites must be determined for each radioligand in order to validate the utility of the radiotracer for measuring the desired physiological process. Thus, the identification of metabolic profiles of radiolabeled compounds is an important aspect of design, development, and validation of new radiopharmaceuticals and their applications in drug development and molecular imaging. Metabolite identification for different chemical classes of radiopharmaceuticals allows rational design to minimize the formation and accumulation of metabolites in the target tissue, either through enhanced excretion or minimized metabolism. This review will discuss methods for identifying and quantitating metabolites during the pre-clinical development of radiopharmaceuticals with special emphasis on the application of LC/MS. PMID:20540692
Satyanarayana Raju, T; Vishweshwari Kutty, O; Ganesh, V; Yadagiri Swamy, P
2012-08-01
Although a number of methods are available for evaluating Linezolid and its possible impurities, a common method for separation if its potential impurities, degradants and enantiomer in a single method with good efficiency remain unavailable. With the objective of developing an advanced method with shorter runtimes, a simple, precise, accurate stability-indicating LC method was developed for the determination of purity of Linezolid drug substance and drug products in bulk samples and pharmaceutical dosage forms in the presence of its impurities and degradation products. This method is capable of separating all the related substances of Linezolid along with the chiral impurity. This method can also be used for the estimation of assay of Linezolid in drug substance as well as in drug product. The method was developed using Chiralpak IA (250 mm×4.6 mm, 5 μm) column. A mixture of acetonitrile, ethanol, n-butyl amine and trifluoro acetic acid in 96:4:0.10:0.16 (v/v/v/v) ratio was used as a mobile phase. The eluted compounds were monitored at 254 nm. Linezolid was subjected to the stress conditions of oxidative, acid, base, hydrolytic, thermal and photolytic degradation. The degradation products were well resolved from main peak and its impurities, proving the stability-indicating power of the method. The developed method was validated as per International Conference on Harmonization (ICH) guidelines with respect to specificity, limit of detection, limit of quantification, precision, linearity, accuracy, robustness and system suitability.
Andersson, Maria; Stephanson, Nikolai; Ohman, Inger; Terzuoli, Tommy; Lindh, Jonatan D; Beck, Olof
2014-04-01
Opiates comprise a class of abused drugs that is of primary interest in clinical and forensic urine drug testing. Determination of heroin, codeine, or a multi-drug ingestion is complicated since both heroin and codeine can lead to urinary excretion of free and conjugated morphine. Liquid chromatography-tandem mass spectrometry (LC-MS/MS) offers advantage over gas chromatography-mass spectrometry by simplifying sample preparation but increases the number of analytes. A method based on direct injection of five-fold diluted urine for confirmation of morphine, morphine-3-glucuronide, morphine-6-glucuronide, codeine, codeine-6-glucuronide and 6-acetylmorphine was validated using LC-MS/MS in positive electrospray mode monitoring two transitions using selected reaction monitoring. The method was applied for the analysis of 3155 unknown urine samples which were positive for opiates in immunochemical screening. A linear response was observed for all compounds in the calibration curves covering more than three orders of magnitude. Cut off was set to 2 ng/ml for 6-acetylmorphine and 150 ng/ml for the other analytes. 6-Acetylmorphine was found to be effective (sensitivity 82%) in detecting samples as heroin intake. Morphine-3-glucuronide and codeine-6-glucuronide was the predominant components of total morphine and codeine, 84% and 93%, respectively. The authors have validated a robust LC-MS/MS method for rapid qualitative and quantitative analysis of opiates in urine. 6-Acetylmorphine has been demonstrated as a sensitive and important parameter for a heroin intake. A possible interpretation strategy to conclude the source of detected analytes was proposed. The method might be further developed by reducing the number of analytes to morphine-3-glucuronide, codeine-6-glucuronide and 6-acetylmorphine without compromising test performance. Copyright © 2013 John Wiley & Sons, Ltd.
Fæste, Christiane Kruse; Moen, Anders; Schniedewind, Björn; Haug Anonsen, Jan; Klawitter, Jelena; Christians, Uwe
2016-02-05
The parasite Anisakis simplex is present in many marine fish species that are directly used as food or in processed products. The anisakid larvae infect mostly the gut and inner organs of fish but have also been shown to penetrate into the fillet. Thus, human health can be at risk, either by contracting anisakiasis through the consumption of raw or under-cooked fish, or by sensitisation to anisakid proteins in processed food. A number of different methods for the detection of A. simplex in fish and products thereof have been developed, including visual techniques and PCR for larvae tracing, and immunological assays for the determination of proteins. The recent identification of a number of anisakid proteins by mass spectrometry-based proteomics has laid the groundwork for the development of two quantitative liquid chromatography-tandem mass spectrometry methods for the detection of A. simplex in fish that are described in the present study. Both, the label-free semi-quantitative nLC-nESI-Orbitrap-MS/MS (MS1) and the heavy peptide-applying absolute-quantitative (AQUA) LC-TripleQ-MS/MS (MS2) use unique reporter peptides derived from anisakid hemoglobin and SXP/RAL-2 protein as analytes. Standard curves in buffer and in salmon matrix showed limits of detection at 1μg/mL and 10μg/mL for MS1 and 0.1μg/mL and 2μg/mL for MS2. Preliminary method validation included the assessment of sensitivity, repeatability, reproducibility, and applicability to incurred and naturally-contaminated samples for both assays. By further optimization and full validation in accordance with current recommendations the LC-MS/MS methods could be standardized and used generally as confirmative techniques for the detection of A. simplex protein in fish. Copyright © 2016 Elsevier B.V. All rights reserved.
Gerona, Roy; Wen, Anita; Chin, Aaron T.; Koss, Catherine A.; Bacchetti, Peter; Metcalfe, John; Gandhi, Monica
2016-01-01
Background Tuberculosis (TB) is the leading cause of death from an infectious pathogen worldwide and the most prevalent opportunistic infection in people living with HIV. Isoniazid preventive therapy (IPT) reduces the incidence of active TB and reduces morbidity and mortality in HIV-infected patients independently of antiretroviral therapy. However, treatment of latent or active TB is lengthy and inter-patient variability in pharmacokinetics and adherence common. Current methods of assessing adherence to TB treatment using drug levels in plasma or urine assess short-term exposure and pose logistical challenges. Drug concentrations in hair assess long-term exposure and have demonstrated pharmacodynamic relevance in HIV. Methods A large hair sample from a patient with active TB was obtained for assay development. Methods to pulverize hair and extract isoniazid were optimized and then the drug detected by liquid chromatography/ tandem mass spectrometry (LC/MS-MS). The method was validated for specificity, accuracy, precision, recovery, linearity and stability to establish the assay’s suitability for therapeutic drug monitoring (TDM). Hair samples from patients on directly-observe isoniazid-based latent or active TB therapy from the San Francisco Department of Public Health TB clinic were then tested. Results Our LC/MS-MS-based assay detected isoniazid in quantities as low as 0.02ng/mg using 10–25 strands hair. Concentrations in spiked samples demonstrated linearity from 0.05–50ng/mg. Assay precision and accuracy for spiked quality-control samples were high, with an overall recovery rate of 79.5%. In 18 patients with latent or active TB on treatment, isoniazid was detected across a wide linear dynamic range. Conclusions An LC-MS/MS-based assay to quantify isoniazid levels in hair with performance characteristics suitable for TDM was developed and validated. Hair concentrations of isoniazid assess long-term exposure and may be useful for monitoring adherence to latent or active TB treatment in the setting of HIV. PMID:27191185
ERIC Educational Resources Information Center
Homem, Vera; Alves, Arminda; Santos, Lu´cia
2014-01-01
A laboratory application with a strong component in analytical chemistry was designed for undergraduate students, in order to introduce a current problem in the environmental science field, the water contamination by antibiotics. Therefore, a simple and rapid method based on direct injection and high performance liquid chromatography-tandem mass…
Gil, Jeovanis; Cabrales, Ania; Reyes, Osvaldo; Morera, Vivian; Betancourt, Lázaro; Sánchez, Aniel; García, Gerardo; Moya, Galina; Padrón, Gabriel; Besada, Vladimir; González, Luis Javier
2012-02-23
Growth hormone-releasing peptide 6 (GHRP-6, His-(DTrp)-Ala-Trp-(DPhe)-Lys-NH₂, MW=872.44 Da) is a potent growth hormone secretagogue that exhibits a cytoprotective effect, maintaining tissue viability during acute ischemia/reperfusion episodes in different organs like small bowel, liver and kidneys. In the present work a quantitative method to analyze GHRP-6 in human plasma was developed and fully validated following FDA guidelines. The method uses an internal standard (IS) of GHRP-6 with ¹³C-labeled Alanine for quantification. Sample processing includes a precipitation step with cold acetone to remove the most abundant plasma proteins, recovering the GHRP-6 peptide with a high yield. Quantification was achieved by LC-MS in positive full scan mode in a Q-Tof mass spectrometer. The sensitivity of the method was evaluated, establishing the lower limit of quantification at 5 ng/mL and a range for the calibration curve from 5 ng/mL to 50 ng/mL. A dilution integrity test was performed to analyze samples at higher concentration of GHRP-6. The validation process involved five calibration curves and the analysis of quality control samples to determine accuracy and precision. The calibration curves showed R² higher than 0.988. The stability of the analyte and its internal standard (IS) was demonstrated in all conditions the samples would experience in a real time analyses. This method was applied to the quantification of GHRP-6 in plasma from nine healthy volunteers participating in a phase I clinical trial. Copyright © 2011 Elsevier B.V. All rights reserved.
Déglon, Julien; Versace, François; Lauer, Estelle; Widmer, Christèle; Mangin, Patrice; Thomas, Aurélien; Staub, Christian
2012-06-01
Dried blood spots (DBS) sampling has gained popularity in the bioanalytical community as an alternative to conventional plasma sampling, as it provides numerous benefits in terms of sample collection and logistics. The aim of this work was to show that these advantages can be coupled with a simple and cost-effective sample pretreatment, with subsequent rapid LC-MS/MS analysis for quantitation of 15 benzodiazepines, six metabolites and three Z-drugs. For this purpose, a simplified offline procedure was developed that consisted of letting a 5-µl DBS infuse directly into 100 µl of MeOH, in a conventional LC vial. The parameters related to the DBS pretreatment, such as extraction time or internal standard addition, were investigated and optimized, demonstrating that passive infusion in a regular LC vial was sufficient to quantitatively extract the analytes of interest. The method was validated according to international criteria in the therapeutic concentration ranges of the selected compounds. The presented strategy proved to be efficient for the rapid analysis of the selected drugs. Indeed, the offline sample preparation was reduced to a minimum, using a small amount of organic solvent and consumables, without affecting the accuracy of the method. Thus, this approach enables simple and rapid DBS analysis, even when using a non-DBS-dedicated autosampler, while lowering the costs and environmental impact.
Fast targeted analysis of 132 acidic and neutral drugs and poisons in whole blood using LC-MS/MS.
Di Rago, Matthew; Saar, Eva; Rodda, Luke N; Turfus, Sophie; Kotsos, Alex; Gerostamoulos, Dimitri; Drummer, Olaf H
2014-10-01
The aim of this study was to develop an LC-MS/MS based screening technique that covers a broad range of acidic and neutral drugs and poisons by combining a small sample volume and efficient extraction technique with simple automated data processing. After protein precipitation of 100μL of whole blood, 132 common acidic and neutral drugs and poisons including non-steroidal anti-inflammatory drugs, barbiturates, anticonvulsants, antidiabetics, muscle relaxants, diuretics and superwarfarin rodenticides (47 quantitated, 85 reported as detected) were separated using a Shimadzu Prominence HPLC system with a C18 separation column (Kinetex XB-C18, 4.6mm×150mm, 5μm), using gradient elution with a mobile phase of 25mM ammonium acetate buffer (pH 7.5)/acetonitrile. The drugs were detected using an ABSciex(®) API 2000 LC-MS/MS system (ESI+ and -, MRM mode, two transitions per analyte). The method was fully validated in accordance with international guidelines. Quantification data obtained using one-point calibration compared favorably to that using multiple calibrants. The presented LC-MS/MS assay has proven to be applicable for determination of the analytes in blood. The fast and reliable extraction method combined with automated processing gives the opportunity for high throughput and fast turnaround times for forensic and clinical toxicology. Copyright © 2014 Elsevier Ireland Ltd. All rights reserved.
He, Jun; Bo, Fang; Tu, Yaru; Azietaku, John Teye; Dou, Ting; Ouyang, Huizi; Chang, Yanxu; Liu, Hong; Gao, Xiumei
2015-10-10
A sensitive and reliable LC-MS/MS method was developed and validated for the simultaneous determination of periplocin and its two metabolites (periplocymarin and periplogenin) in rat plasma using psoralen as the internal standard (IS). After liquid-liquid extraction with ethyl acetate, chromatographic separation was performed on a C18 column with a 13 min gradient elution using 0.1% formic acid and acetonitrile as mobile phase at a flow rate of 0.3 mL/min. The detection was accomplished on a tandem mass spectrometer via an electrospray ionization (ESI) source by multiple reaction monitoring (MRM) in the positive ionization mode. The lower limits of quantitation (LLOQs) for periplocin, periplocymarin and periplogenin were 0.5, 1 and 0.1 ng/mL, respectively. The mean recoveries of the analytes and IS were higher than 67.7%. The proposed method was successfully applied to evaluating the pharmacokinetic studies of periplocin and its metabolites (periplocymarin and periplogenin) in rats after a single oral administration of periplocin at 50 mg/kg. Copyright © 2015 Elsevier B.V. All rights reserved.
Lawson, Graham; Cocks, Elizabeth; Tanna, Sangeeta
2012-05-15
The use of blood spot collection cards was investigated as a means of obtaining small volume samples for the quantification of therapeutic drugs for assessing medication adherence. A liquid chromatography-high resolution TOF mass spectrometry (LC-HRMS) method, based on the measurement at the accurate mass to charge ratio of the target analyte, was used to ensure specificity for atenolol in the dried blood spot (DBS) samples. A working method was developed and validated. For the preparation of DBS samples whole blood spiked with analyte was used to produce 30 μl blood spots on specimen collection cards. A 5mm disc was cut from the dried blood spot and extracted using methanol:water (60:40, v/v) containing the internal standard, atenolol-d(7). Extracts were vortexed, sonicated and then centrifuged. Gradient chromatographic elution was achieved using an Ascentis Express C18 100mm×2.1mm column and a mobile phase flow rate of 0.2 ml/min and the column oven temperature at 30 °C. MS detection was carried out in electrospray positive ion mode for target ions at accurate mass m/z 267.1703 for atenolol and 274.2143 for the IS. Drug extraction efficiency from spiked blood spots was demonstrated to be 96±5% and the drug was stable in DBS for at least 10 weeks. The developed LC-HRMS method was linear within the tested calibration range of 25-1500 ng/ml and validation showed the accuracy (relative error) and precision (coefficient of variation) values were within the pre-defined limits of ≤ 5% at all concentrations with a limit of quantification of 25 ng/ml. Factors with potential to affect drug quantification measurements such as the matrix effects, volume of blood applied onto the collection card and effect of different sampling cards were investigated. The developed LC-HRMS method was applied to blood spots on sampling card taken from adult healthy volunteers previously administered a 50mg atenolol tablet and a DBS concentration-time profile was obtained for atenolol. Requiring only a micro volume (30 μl) blood sample for analysis, the developed DBS based assay has the potential to assess patient adherence to atenolol. Copyright © 2012 Elsevier B.V. All rights reserved.
Albahrani, Ali A; Rotarou, Victor; Roche, Peter J; Greaves, Ronda F
2016-05-01
Non-classical roles of fat-soluble vitamins (FSVs) in many pathologies including cancer have been identified. There is also evidence of hormonal interactions between two of these vitamins, A and D. As a result of this enhanced clinical association with disease, translational clinical research and laboratory requests for FSV measurement has significantly increased. However there are still gaps in the analytical methods available for the measurement of these vitamins. This study aimed to develop a method for simultaneous quantification of 25-hydroxyvitamin-D2 (25-OHD2), 25-hydroxyvitamin-D3 (25-OHD3) and its 3-epimer (epi-25-OHD3), retinol and α-tocopherol in human serum using liquid chromatography-tandem mass spectrometry (LC-MS/MS). The procedure was developed and validated across two LC-MS/MS platforms, using commercial calibrators referenced to certified reference materials, controls, and deuterated internal standards. The samples were prepared by liquid-liquid extraction prior to injection and LC separation (using a Pursuit-PFP column) on two Agilent MS/MS systems (6410 and 6490) in electrospray ionisation positive mode with multiple reaction monitoring. Identification and quantification of 25-OHD3 from its 3-epimer as well as 25-OHD2, retinol and α-tocopherol were achieved. The dynamic ranges were 4-160 nmol/L for 25-OHD2 and epi-25-OHD3, 4-200 nmol/L for 25-OHD3, 0.1-4.0μmol/L for retinol and 4-70μmol/L for α-tocopherol with correlation (r(2)) of 0.997-0.998. Based on participation in an external quality assurance program, the overall performance of the simultaneous methods were: imprecision (CV%) and inaccuracy (average bias) 3.0% and 3.2 nmol/L, respectively, for 25-OHD3; 5.0% and 0.04μmol/L, respectively, for retinol; and 4.7% and 0.2μmol/L, respectively, for α-tocopherol. In summary, two simple LC-MS/MS methods were successfully developed and validated for the simultaneous quantification of the three vitamin D metabolites (25-OHD2, 25-OHD3 and 3-epimer of 25-OHD3), vitamin A (retinol) and vitamin E (α-tocopherol) in serum. Copyright © 2016 Elsevier Ltd. All rights reserved.
Noyes, Pamela D.; Lema, Sean C.; Roberts, Simon C.; Cooper, Ellen M.
2014-01-01
Thyroid hormones are critical regulators of normal development and physiological functioning in all vertebrates. Radioimmunoassay (RIA) approaches have been the method of choice for measuring circulating levels of thyroid hormones in vertebrates. While sensitive, RIA-based approaches only allow for a single analyte measurement per assay, can lack concordance across platforms and laboratories, and can be prone to analytical interferences especially when used with fish plasma. Ongoing advances in liquid chromatography tandem mass spectrometry (LC/MS/MS) have led to substantial decreases in detection limits for thyroid hormones and other biomolecules in complex matrices, including human plasma. Despite these advances, current analytical approaches do not allow for the measurement of native thyroid hormone in teleost fish plasma by mass spectrometry and continue to rely on immunoassay. In this study, we developed a new method that allows for the rapid extraction and simultaneous measurement of total T4 (TT4) and total T3 (TT3) in low volumes (50 μL) of fish plasma by LC/MS/MS. Methods were optimized initially in plasma from rainbow trout (Oncorhynchus mykiss) and applied to plasma from other teleost fishes, including fathead minnows (Pimephales promelas), mummichogs (Fundulus heteroclitus), sockeye salmon (Oncorhynchus nerka), and coho salmon (Oncorhynchus kisutch). Validation of method performance with T4- and T3-spiked rainbow trout plasma at 2 and 4 ng/mL produced mean recoveries ranging from 82 to 95 % and 97 to 105 %, respectively. Recovery of 13C12-T4 internal standard in plasma extractions was: 99±1.8 % in rainbow trout, 85±11 % in fathead minnow, 73±5.0 % in mummichog, 73±1.7 % in sockeye salmon, and 80±8.4 % in coho salmon. While absolute levels of thyroid hormones measured in identical plasma samples by LC/MS/MS and RIA varied depending on the assay used, T4/T3 ratios were generally consistent across both techniques. Less variability was measured among samples subjected to LC/MS/MS suggesting a more precise estimate of thyroid hormone homeostasis in the species targeted. Overall, a sensitive and reproducible method was established that takes advantage of LC/MS/MS techniques to rapidly measure TT4 and TT3 with negligible interferences in low volumes of plasma across a variety of teleost fishes. PMID:24343452
Scheidweiler, Karl B; Jarvis, Michael J Y; Huestis, Marilyn A
2015-01-01
Clandestine laboratories constantly produce new synthetic cannabinoids to circumvent legislative scheduling efforts, challenging and complicating toxicological analysis. Sundstrom et al. (Anal Bioanal Chem 405(26):8463-8474, [9]) and Kronstrand et al. (Anal Bioanal Chem 406(15):3599-3609, [10]) published nontargeted liquid chromatography, high-resolution, quadrupole/time-of-flight mass spectrometric (LC-QTOF) assays with validated detection of 18 and 38 urinary synthetic cannabinoid metabolites, respectively. We developed and validated a LC-QTOF urine method for simultaneously identifying the most current 47 synthetic cannabinoid metabolites from 21 synthetic cannabinoid families (5-fluoro AB-PINACA, 5-fluoro-AKB48, 5-fluoro PB-22, AB-PINACA, ADB-PINACA, AKB48, AM2201, JWH-018, JWH-019, JWH-073, JWH-081, JWH-122, JWH-200, JWH-210, JWH-250, JWH-398, MAM2201, PB-22, RCS-4, UR-144, and XLR11). β-Glucuronidase-hydrolyzed urine was extracted with 1-mL Biotage SLE+ columns. Specimens were reconstituted in 150-μL mobile phase consisting of 80% A (0.1% formic acid in water) and 20% B (0.1% formic acid in acetonitrile). Fifty microliters was injected, and SWATH™ MS data were acquired in positive electrospray mode. The LC-QTOF instrument consisted of a Shimadzu UFLCxr system and an ABSciex 5600+ TripleTOF® mass spectrometer. Gradient chromatographic separation was achieved with a Restek Ultra Biphenyl column with a 0.5-mL/min flow rate and an overall run time of 15 min. Identification criteria included molecular ion mass error, isotopic profiles, retention time, and library fit criteria. Limits of detection were 0.25-5 μg/L (N = 10 unique fortified urine samples), except for two PB-22 metabolites with limits of 10 and 20 μg/L. Extraction efficiencies and matrix effects (N = 10) were 55-104 and -65-107%, respectively. We present a highly useful novel LC-QTOF method for simultaneously confirming 47 synthetic cannabinoid metabolites in human urine.
Ge, Shufan; Gao, Song; Yin, Taijun; Hu, Ming
2015-03-25
Chrysin, a flavone found in many plants, is also available as a dietary supplement because of its reported anticancer activities. However, its bioavailability is very poor due to extensive phase II metabolism. The purpose of this study was to develop an UPLC-MS/MS method to simultaneously quantify chrysin and its phase II metabolites, and to determine its pharmacokinetics in FVB wild-type and Bcrp knockout (Bcrp1 -/-) mice. In addition, the role of BCRP in chrysin phase II disposition was further investigated in Caco-2 cells. The results showed that our sensitive and reproducible UPLC-MS/MS method was successfully applied to the pharmacokinetic study of chrysin in wild-type and Bcrp1 (-/-) FVB mice after oral administration (20 mg/kg). Although there was no significant change in systemic exposure of chrysin and its metabolites, it was found that the Tmax for chrysin glucuronide was significantly shorter (p < 0.01) in Bcrp1-deficient mice. Furthermore, it was shown that inhibition of BCRP by Ko143 significantly reduced the efflux of chrysin sulfate in Caco-2 cells. In conclusion, BCRP had significant but less than expected impact on pharmacokinetics of chrysin and its conjugates, which were determined using a newly developed and validated LC-MS/MS method.
Striegel, Lisa; Chebib, Soraya; Netzel, Michael E.; Rychlik, Michael
2018-01-01
Folates play an important role in the human body and a deficiency of this vitamin can cause several diseases. Therefore, a reliable analytical method is crucial for the determination of folate vitamers in strawberries and other dietary folate sources. A stable isotope dilution LC-MS/MS method for analyzing folates in food was developed and validated. The folate vitamers Pteroylmonoglutamic acid, tetrahydrofolate, 5-methyltetrahydrofolate, and 5-formyltetrahydrofolate were quantified using 13C-labeled internal standards. Validation of the assay was accomplished by determining linearity, precision, recovery, limit of detection, and limit of quantification and revealed to be a precise, sensitive, and accurate method to determine folate vitamers. Strawberries are worldwide consumed and known to be a good dietary source of nutritive compounds. Using this method, folate concentrations in selected commercial strawberry cultivars and experimental breeding lines grown in Germany and Australia were investigated. Total folates varied from 59 to 153 μg/100 g on fresh weight basis. Furthermore, folate content after lyophilizing or freezing did not show any significant differences compared to fresh strawberries. However, significant losses of total folates in pureed strawberries could be observed after 5 days of storage with only 16% of the original concentration retained. In summary, some of the investigated strawberry cultivars/breeding lines can be considered as rich dietary sources of natural folates. PMID:29468149
Qiu, Feng; Zhou, Shujun; Fu, Shujun; Kong, Weijun; Yang, Shihai; Yang, Meihua
2012-11-01
A sensitive and accurate LC-ESI-MS/MS method was developed and validated of for the determination of 6'-hydroxy justicidin A (HJA), a potential antitumor active component isolated from Justicia procumbens in rat plasma using a simple liquid-liquid extraction (LLE) method for sample preparation. Chromatographic separation was achieved on an Agilent Zorbax-C(18) column (2.1 mm × 50 mm, 3.5 μm) using a step gradient program with the mobile phase of 0.1% formic acid aqueous solution and acetonitrile with 0.1% formic acid. HJA and IS (buspirone) were detected using electrospray positive ionization mass spectrometry in the multiple reaction monitoring (MRM) mode. This method demonstrated good linearity and did not show any endogenous interference with the active compound and IS peaks. The lower limit of quantification (LLOQ) of HJA was 0.50 ng/ml in 50 μl rat plasma. The developed and validated method has been successfully applied to the quantification and pharmacokinetic study of HJA in rats after intravenous and oral administration of 0.25 mg/kg HJA. The oral bioavailability (F) of HJA was estimated to be 36.0±13.4% with an elimination half-life (t(1/2)) value of 1.04±0.20 h. Copyright © 2012 Elsevier B.V. All rights reserved.
Bharathi, D Vijaya; Hotha, Kishore Kumar; Sagar, P V Vidya; Kumar, S Sirish; Naidu, A; Mullangi, Ramesh
2009-02-01
A highly sensitive and specific LC-MS/MS method has been developed and validated for the estimation of pramipexole (PPX) with 500 microL human plasma using memantine as an internal standard (IS). The API-4000 was operated under multiple-reaction monitoring mode (MRM) using the electrospray ionization technique. Solid-phase extraction was used to extract PPX and IS from human plasma. The resolution of peaks was achieved with 0.01 m ammonium acetate buffer (pH 4.4):acetonitrile (30:70, v/v) on a Discovery CN column. The total chromatographic run time was 3.0 min and the elution of PPX and IS occurred at approximately 2.32 and 2.52, respectively. The MS/MS ion transitions monitored were 212.10 --> 153.10 for PPX and 180.20 --> 107.30 for IS. The method was proved to be accurate and precise at linearity range of 20-3540 pg/mL with a correlation coefficient (r) of > or =0.999. The intra- and inter-day precision and accuracy values found to be within the assay variability limits as per the FDA guidelines. The developed assay method was applied to a pharmacokinetic study in human volunteers following oral administration of 0.25 mg PPX tablet. Copyright (c) 2008 John Wiley & Sons, Ltd.
Klausz, Gabriella; Keller, Éva; Sára, Zoltán; Székely-Körmöczy, Péter; Laczay, Péter; Ary, Kornélia; Sótonyi, Péter; Róna, Kálmán
2015-12-01
A liquid chromatography-electrospray-mass spectrometry method (LC/MS) has been developed and validated for determination of praziquantel (PZQ), pyrantel (PYR), febantel (FBT), and the active metabolites fenbendazole (FEN) and oxfendazole (OXF), in dog plasma, using mebendazole as internal standard (IS). The method consists of solid-phase extractions on Strata-X polymeric cartridges. Chromatographic separation was carried out on a Phenomenex Gemini C6 -Phenyl column using binary gradient elution containing methanol and 50 mm ammonium-formate (pH 3). The method was linear (r(2) ≥ 0.990) over concentration ranges of 3-250 ng/mL for PYR andFEB, 5-250 ng/mL for OXF and FEN, and 24-1000 ng/mL for PZQ. The mean precisions were 1.3-10.6% (within-run) and 2.5-9.1% (between-run), and mean accuracies were 90.7-109.4% (within-run) and 91.6-108.2% (between-run). The relative standard deviations (RSD) were <9.1%. The mean recoveries of five targeted compounds from dog plasma ranged from 77 to 94%.The new LC/MS method described herein was fully validated and successfully applied to the bioequivalence studies of different anthelmintic formulations such as tablets containing PZQ, PYR embonate and FBT in dogs after oral administration. Copyright © 2015 John Wiley & Sons, Ltd.
Liu, Xiaoying; Liu, Qian; Wang, Dongmei; Wang, Xueya; Zhang, Peng; Xu, Haiyan; Zhao, Hui; Zhao, Huaiqing
2010-05-01
A highly sensitive and selective LC-MS/MS method was developed and validated for the determination of dauricine in human plasma, using protopine as internal standard (IS). The analyte and IS were extracted by liquid-liquid extraction and analyzed by LC-MS/MS. Chromatographic separation was performed on Agilent TC-C(18) column with a mobile phase of methanol-water-glacial acetic acid (60:40:0.8, v/v/v) at a flow rate of 0.7 mL/min. Detection was performed on a triple quadrupole tandem mass spectrum by multiple reaction monitoring (MRM) mode using the electrospray ionization technique in positive mode. The method was linear over the concentration range of 1-200 ng/mL. The lower limit of quantification (LLOQ) was 1 ng/mL in human plasma with acceptable precision and accuracy. The intra- and inter-day precision was less than 5.9% determined from quality control (QC) samples at concentrations of 2.0, 20.0 and 160 ng/mL, and the accuracy was within +/-9.9%. This method was successfully applied for the evaluation of pharmacokinetics of dauricine after oral doses of 100, 300 and 600 mg phenolic alkaloids of menispermum dauricum tablet (PAMDT) to 12 Chinese healthy volunteers. 2010 Elsevier B.V. All rights reserved.
NASA Astrophysics Data System (ADS)
Striegel, Lisa; Chebib, Soraya; Netzel, Michael E.; Rychlik, Michael
2018-02-01
Folates play an important role in the human body and a deficiency of this vitamin can cause several diseases. Therefore, a reliable analytical method is crucial for the determination of folate vitamers in strawberries and other dietary folate sources. A stable isotope dilution LC-MS/MS method for analyzing folates in food was developed and validated. The folate vitamers Pteroylmonoglutamic acid, tetrahydrofolate, 5-methyltetrahydrofolate and 5-formyltetrahydrofolate were quantified using 13C-labelled internal standards. Validation of the assay was accomplished by determining linearity, precision, recovery, limit of detection and limit of quantification and revealed to be a precise, sensitive and accurate method to determine folate vitamers. Strawberries are worldwide consumed and known to be a good dietary source of nutritive compounds. Using this method, folate concentrations in selected commercial strawberry cultivars and experimental breeding lines grown in Germany were investigated. Total folates varied from 59 to 153 µg/100 g on fresh weight basis. Furthermore, folate content after lyophilizing or freezing did not show any significant differences compared to fresh strawberries. However, significant losses of total folates in pureed strawberries could be observed after 5 days of storage with only 16 % of the original concentration retained. In summary, some of the investigated strawberry cultivars/breeding lines can be considered as rich dietary sources of natural folates.
Simultaneous Determination of 11 Illicit Phenethylamines in Hair by LC-MS-MS: In Vivo Application.
Nieddu, Maria; Burrai, Lucia; Demontis, Maria Piera; Varoni, Maria Vittoria; Baralla, Elena; Trignano, Claudia; Boatto, Gianpiero
2015-09-01
Existing phenethylamines are a class of synthetic compounds that differ from each other only in small changes to a largely conserved chemical structure. The recreational and illicit use of phenethylamines is a widespread problem. A simple procedure for the simultaneous quantitative determination in hair of 11 phenethylamines that are officially recognized as illicit by Italian legislation (p-methoxyamphetamine; p-methoxymethamphetamine; 3,4,5-trimethoxyamphetamine; 2,5-dimethoxyamphetamine; 2,5-dimethoxy-4-methylamphetamine; 2,5-dimethoxy-4-ethylamphetamine; 2,5-dimethoxy-4-bromoamphetamine; 2,5-dimethoxy-4-bromophenethylamine; 2,5-dimethoxy-4-iodophenethylamine; 2,5-dimethoxy-4-ethylthiophenethylamine and 2,5-dimethoxy-4-n-propylthiophenethylamine) has been developed and validated. Extraction from the matrix was performed after incubation in methanolic HCl and filtered reconstituted extracts were injected into a liquid chromatography/tandem mass spectrometry system (LC-MS-MS) without any further purification steps. This validated LC-MS-MS method has been used to determine the in vivo accumulation/retention of the above target analytes in hair after repeat oral administration to rats. This experiment further permitted investigation of the effect of pigmentation on the uptake of these phenethylamines by hair and the effect of hair pigmentation. The developed method could potentially be used for forensic and toxicological purposes, in the detection and quantitation of these illicit substances in human hair in workplace drug testing; drug-facilitated crime investigation; driver re-licensing; determining drug abuse history and postmortem toxicology. © The Author 2015. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.
Li, Bing; Gong, Shi-Yue; Zhou, Xu-Zheng; Yang, Ya-Jun; Li, Jian-Yong; Wei, Xiao-Juan; Cheng, Fu-Sheng; Niu, Jian-Rong; Liu, Xi-Wang; Zhang, Ji-Yu
2017-03-01
A rapid and sensitive high-performance liquid chromatography-tandem mass spectrometry (LC-MS/MS) method was developed and validated to quantify tilmicosin in pig plasma. Plasma samples were prepared by liquid-liquid extraction. Chromatographic separation was achieved on a C 18 column (2.1 × 30 mm, 3.5 μm) using acetonitrile-water (90:10, v/v; water included 0.1% formic acid) as the mobile phase. Mass detection was carried out using positive electrospray ionization in multiple reaction monitoring mode. The calibration curve was linear from 0.5 to 2000 ng/mL (r 2 = 0.9998). The intra- and inter-day accuracy and precision were within the acceptable limits of ±10% for all tilmicosin concentrations. The recoveries ranged from 95 to 99% for the three tested concentrations. The LC-MS/MS method described herein was simple, fast and less laborious than other methods, achieved high sensitivity using a small sample volume, and was successfully applied to pharmacokinetic studies of tilmicosin enteric granules after oral delivery to pigs. In comparison with tilmicosin premix, tilmicosin enteric granules slowed the elimination rate of tilmicosin, prolonged its period of action and significantly improved its bioavailability. Copyright © 2016 John Wiley & Sons, Ltd.
Laryea, Maurice D; Herebian, Diran; Meissner, Thomas; Mayatepek, Ertan
2010-12-01
Inborn errors of urea metabolism result in hyperammonemia. Treatment of urea cycle disorders can effectively lower plasma ammonium levels and results in survival in the majority of patients. Available medications for treating urea cycle disorders include sodium benzoate (BA), sodium phenylacetate (PAA), and sodium phenylbutyrate (PBA) and are given to provide alternate routes for disposition of waste nitrogen excretion. In this study, we develop and validate a liquid chromatography tandem mass spectrometry (LC-MS/MS) method for simultaneous determination of benzoic acid, phenylacetic acid, phenylbutyric acid, phenylacetylglutamine, and hippuric acid in plasma and urine from children with inborn errors of urea synthesis. Plasma extracts and diluted urine samples were injected on a reverse-phase column and identified and quantified by selected reaction monitoring (SRM) in negative ion mode. Deuterated analogues served as internal standards. Analysis time was 7 min. Assay precision, accuracy, and linearity and sample stability were determined using enriched samples. Quantification limits of the method were 100 ng/ml (0.3-0.8 μmol/L) for all analytes, and recoveries were >90%. Inter- and intraday relative standard deviations were <10%. Our newly developed LC-MS/MS represents a robust, sensitive, and rapid method that allows simultaneous determination of the five compounds in plasma and urine.
den Brok, Monique W J; Nuijen, Bastiaan; Hillebrand, Michel J X; Grieshaber, Charles K; Harvey, Michael D; Beijnen, Jos H
2005-09-01
C1311 (5-[[2-(diethylamino)ethyl]amino]-8-hydroxyimidazo [4,5,1-de]-acridin-6-one-dihydrochloride trihydrate) is the lead compound from the group of imidazoacridinones, a novel group of rationally designed anticancer agents. The pharmaceutical development of C1311 necessitated the availability of an assay for the quantification and purity determination of C1311 active pharmaceutical ingredient (API) and its pharmaceutical dosage form. A reversed-phase liquid chromatographic method (RP-LC) with ultraviolet (UV) detection was developed, consisting of separation on a C18 column with phosphate buffer (60 mM; pH 3 with 1 M citric acid)-acetonitrile-triethylamine (83:17:0.05, v/v/v) as the mobile phase and UV-detection at 280 nm. The method was found to be linear over a concentration range of 2.50-100 microg/mL, precise and accurate. Accelerated stress testing showed degradation products, which were well separated from the parent compound, confirming its stability-indicating capacity. Moreover, the use of LC-MS and on-line photo diode array detection enabled us to propose structures for four degradation products. Two of these products were also found as impurities in the API and more abundantly in an impure lot of API.
Munaretto, Juliana S; Viera, Mariela de S; Martins, Manoel L; Adaime, Martha B; Zanella, Renato
2016-11-01
Most of the analytical methods currently applied in food control laboratories are focused on the determination of target compounds using LC coupled to tandem MS, which is an effective technique, but low-resolution MS is limited. Thus, a method for determination of pesticide multiresidues in fruits (pear, apple, and grape) using a modified quick, easy, cheap, effective, rugged, and safe method and LC coupled to quadrupole time-of-flight (Q-TOF) MS was developed and validated. The proposed method showed good linearity (r2 > 0.99) from 1 to 100 μg/L. Recoveries for blank samples spiked at 0.01, 0.04, and 0.10 mg/kg were between 66 and 122%, with RSDs <28%. Respective LOQs for apple, pear, and grape matrixes were 0.01 mg/kg for 112, 120, and 118 compounds, and 0.04 mg/kg for 22, 12, and 17 compounds, and average mass accuracy error was 3.2 ppm. LC with Q-TOF MS detection using protonated molecular ion and/or adducts and mass accuracy provided reliability for the method. The proposed method is effective for pesticide residue determination in apple, pear, and grape samples, proving that high-resolution MS using full scan mode can be a powerful and reliable technique for quantification purposes, being adequate for application in the surveillance of maximum residue limits set by different legislations.
Herzog, Bastian; Lemmer, Hilde; Horn, Harald; Müller, Elisabeth
2014-02-22
Evaluation of xenobiotics biodegradation potential, shown here for benzotriazoles (corrosion inhibitors) and sulfamethoxazole (sulfonamide antibiotic) by microbial communities and/or pure cultures normally requires time intensive and money consuming LC/GC methods that are, in case of laboratory setups, not always needed. The usage of high concentrations to apply a high selective pressure on the microbial communities/pure cultures in laboratory setups, a simple UV-absorbance measurement (UV-AM) was developed and validated for screening a large number of setups, requiring almost no preparation and significantly less time and money compared to LC/GC methods. This rapid and easy to use method was evaluated by comparing its measured values to LC-UV and GC-MS/MS results. Furthermore, its application for monitoring and screening unknown activated sludge communities (ASC) and mixed pure cultures has been tested and approved to detect biodegradation of benzotriazole (BTri), 4- and 5-tolyltriazole (4-TTri, 5-TTri) as well as SMX. In laboratory setups, xenobiotics concentrations above 1.0 mg L(-1) without any enrichment or preparation could be detected after optimization of the method. As UV-AM does not require much preparatory work and can be conducted in 96 or even 384 well plate formats, the number of possible parallel setups and screening efficiency was significantly increased while analytic and laboratory costs were reduced to a minimum.
Hroch, Miloš; Mičuda, Stanislav; Havelek, Radim; Cermanová, Jolana; Cahlíková, Lucie; Hošťálková, Anna; Hulcová, Daniela; Řezáčová, Martina
2016-07-01
Evidence gathered in various studies points to the fact that haemanthamine, an isoquinoline alkaloid, has multiple medicinally interesting characteristics, including antitumor, antileukemic, antioxidant, antiviral, anticonvulsant and antimalarial activity. This work presents, for the first time, a universal LC-MS/MS method for analysis of haemanthamine in plasma, bile and urine which has been verified in a pilot pharmacokinetic experiment on rats. Chromatographic separation was performed on a pentafluorophenyl core-shell column in gradient elution mode with a mobile phase consisting of acetonitrile-methanol-ammonium formate buffer. A sample preparation based on liquid-liquid extraction with methyl tert-butyl ether was employed with ambelline used as an internal standard. Quantification was performed using LC-MS-ESI(+) in Selected Reaction Monitoring mode. The method was validated according to the European Medicines Agency guideline in a concentration range of 0.1-10 μmol/L in plasma, bile and urine. The concentration-time profiles of haemanthamine in plasma, bile and urine after a single i.v. bolus of 10 mg/kg have been described for the first time. The presented study addresses the lack of information on haemanthamine pharmacokinetics and also introduces a new universal method of haemanthamine analysis in complex biological matrices. Copyright © 2015 John Wiley & Sons, Ltd. Copyright © 2015 John Wiley & Sons, Ltd.
2014-01-01
Background Evaluation of xenobiotics biodegradation potential, shown here for benzotriazoles (corrosion inhibitors) and sulfamethoxazole (sulfonamide antibiotic) by microbial communities and/or pure cultures normally requires time intensive and money consuming LC/GC methods that are, in case of laboratory setups, not always needed. Results The usage of high concentrations to apply a high selective pressure on the microbial communities/pure cultures in laboratory setups, a simple UV-absorbance measurement (UV-AM) was developed and validated for screening a large number of setups, requiring almost no preparation and significantly less time and money compared to LC/GC methods. This rapid and easy to use method was evaluated by comparing its measured values to LC-UV and GC-MS/MS results. Furthermore, its application for monitoring and screening unknown activated sludge communities (ASC) and mixed pure cultures has been tested and approved to detect biodegradation of benzotriazole (BTri), 4- and 5-tolyltriazole (4-TTri, 5-TTri) as well as SMX. Conclusions In laboratory setups, xenobiotics concentrations above 1.0 mg L-1 without any enrichment or preparation could be detected after optimization of the method. As UV-AM does not require much preparatory work and can be conducted in 96 or even 384 well plate formats, the number of possible parallel setups and screening efficiency was significantly increased while analytic and laboratory costs were reduced to a minimum. PMID:24558966
Chatterjee, Niladri Sekhar; Kumar, K Ashok; Ajeeshkumar, K K; Kumari, K R Remya; Vishnu, K V; Anandan, Rangasamy; Mathew, Suseela; Ravishankar, C N
2017-05-01
Despite the potential of LC with tandem MS (MS/MS) in improving sensitivity and selectivity, analytical methods are scarce for the determination of protein-bound and phosphorylated forms of B vitamins in food. This prompted us to develop a method for LC-MS/MS determination of naturally occurring nicotinamide, nicotinic acid, thiamine, pyridoxine, riboflavin, pantothenic acid, biotin, folic acid, and cyanocobalamin in fish. Baseline separation of the vitamins was achieved in a hydrophilic interaction LC condition. An ultrasonication-assisted enzymatic extraction protocol for sample preparation was optimized and validated. The time required for extraction was significantly reduced (to 4 h), while maintaining good extraction efficiency. Acetonitrile content (80%, v/v) in the prepared sample was found to be optimum for excellent peak shape and sensitivity. The dynamic linear range of the vitamins ranged from 2.5 to 500 ng/g, and the regression coefficient values were greater than 0.99. LOQ values ranged from 0.4 to 50 ng/g for the different vitamins. The spike recovery values at 50 and 100 ng/g ranged from 87.5 to 97.5%. The intra- and interday precision values were satisfactory. Accuracy of the developed method was determined by analysis of a Certified Reference Material. The method could also be used for unambiguous determination of the natural content of the target vitamins in fish.
Liu, Liling; Cui, Zhiyi; Deng, Yuzhong; Dean, Brian; Hop, Cornelis E C A; Liang, Xiaorong
2016-02-01
A high-performance liquid chromatography tandem mass spectrometry (LC-MS/MS) assay for the quantitative determination of NAD(+) in human whole blood using a surrogate analyte approach was developed and validated. Human whole blood was acidified using 0.5N perchloric acid at a ratio of 1:3 (v:v, blood:perchloric acid) during sample collection. 25μL of acidified blood was extracted using a protein precipitation method and the resulting extracts were analyzed using reverse-phase chromatography and positive electrospray ionization mass spectrometry. (13)C5-NAD(+) was used as the surrogate analyte for authentic analyte, NAD(+). The standard curve ranging from 0.250 to 25.0μg/mL in acidified human blood for (13)C5-NAD(+) was fitted to a 1/x(2) weighted linear regression model. The LC-MS/MS response between surrogate analyte and authentic analyte at the same concentration was obtained before and after the batch run. This response factor was not applied when determining the NAD(+) concentration from the (13)C5-NAD(+) standard curve since the percent difference was less than 5%. The precision and accuracy of the LC-MS/MS assay based on the five analytical QC levels were well within the acceptance criteria from both FDA and EMA guidance for bioanalytical method validation. Average extraction recovery of (13)C5-NAD(+) was 94.6% across the curve range. Matrix factor was 0.99 for both high and low QC indicating minimal ion suppression or enhancement. The validated assay was used to measure the baseline level of NAD(+) in 29 male and 21 female human subjects. This assay was also used to study the circadian effect of endogenous level of NAD(+) in 10 human subjects. Copyright © 2015 Elsevier B.V. All rights reserved.
The (Un)Certainty of Selectivity in Liquid Chromatography Tandem Mass Spectrometry
NASA Astrophysics Data System (ADS)
Berendsen, Bjorn J. A.; Stolker, Linda A. M.; Nielen, Michel W. F.
2013-01-01
We developed a procedure to determine the "identification power" of an LC-MS/MS method operated in the MRM acquisition mode, which is related to its selectivity. The probability of any compound showing the same precursor ion, product ions, and retention time as the compound of interest is used as a measure of selectivity. This is calculated based upon empirical models constructed from three very large compound databases. Based upon the final probability estimation, additional measures to assure unambiguous identification can be taken, like the selection of different or additional product ions. The reported procedure in combination with criteria for relative ion abundances results in a powerful technique to determine the (un)certainty of the selectivity of any LC-MS/MS analysis and thus the risk of false positive results. Furthermore, the procedure is very useful as a tool to validate method selectivity.
Chang, Li-Wen; Hou, Mei-Ling; Tsai, Tung-Hu
2014-12-03
The aim of this study was to prepare silymarin formulations (silymarin entrapped in liposomes and ethosomes, formulations referred to as LSM and ESM, respectively) to improve oral bioavailability of silymarin and evaluate its tissue distribution by liquid chromatography with tandem mass spectrometry (LC-MS/MS) in free-moving rats. Silibinin is the major active constituent of silymarin, which is the main component to be analyzed. A rapid, sensitive, and repeatable LC-MS/MS method was developed and validated in terms of precision, accuracy, and extraction recovery. Furthermore, the established method was applied to study the pharmacokinetics and tissue distribution of silymarin in rats. The size, ζ potential, and drug release of the formulations were characterized. These results showed that the LSM and ESM encapsulated formulations of silymarin may provide more efficient tissue distribution and increased oral bioavailability, thus improving its therapeutic bioactive properties in the body.
Kang, Kyungsu; Peng, Lei; Jung, Yu-Jin; Kim, Joo Yeon; Lee, Eun Ha; Lee, Hee Ju; Kim, Sang Min; Sung, Sang Hyun; Pan, Cheol-Ho; Choi, Yongsoo
2018-02-01
To develop a high-throughput screening system to measure the conversion of testosterone to dihydrotestosterone (DHT) in cultured human prostate cancer cells using turbulent flow chromatography liquid chromatography-triple quadrupole mass spectrometry (TFC-LC-TQMS). After optimizing the cell reaction system, this method demonstrated a screening capability of 103 samples, including 78 single compounds and 25 extracts, in less than 12 h without manual sample preparation. Consequently, fucoxanthin, phenethyl caffeate, and Curcuma longa L. extract were validated as bioactive chemicals that inhibited DHT production in cultured DU145 cells. In addition, naringenin boosted DHT production in DU145 cells. The method can facilitate the discovery of bioactive chemicals that modulate the DHT production, and four phytochemicals are potential candidates of nutraceuticals to adjust DHT levels in male hormonal dysfunction.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Ang, C.Y.W.; Luo, Wenhong
1997-01-01
A rapid and sensitive liquid chromatographic (LC) method was developed for the determination of ampicillin residues in raw bovine milk, processed skim milk, and pasteurized, homogenized whole milk with vitamin D. Milk samples were deproteinized with trichloroacetic acid (TCA) and acetonictrile. After centrifugation, the clear supernatant was reacted with formaldehyde and TCA under heat. The major fluorescent derivative of ampicillin was then determined by reversed-phase LC with fluorescence detection. Average recoveries of ampicillin fortified at 5, 10, and 20 ppb (ng/mL) were all >85% with coefficients of variation <10%. Limits of detection ranged from 0.31 to 0.51 ppb and limitsmore » of quantitation, from 0.66 to 1.2 ppb. After appropriate validation, this method should be suitable for rapid analysis of milk for ampicillin residues at the tolerance level of 10 ppb. 16 refs., 4 figs., 3 tabs.« less
Sarah, S A; Faradalila, W N; Salwani, M S; Amin, I; Karsani, S A; Sazili, A Q
2016-05-15
The purpose of this study was to identify porcine-specific peptide markers from thermally processed meat that could differentiate pork from beef, chevon and chicken meat. In the initial stage, markers from tryptic digested protein of chilled, boiled and autoclaved pork were identified using LC-QTOF-MS. An MRM method was then established for verification. A thorough investigation of LC-QTOF-MS data showed that only seven porcine-specific peptides were consistently detected. Among these peptides, two were derived from lactate dehydrogenase, one from creatine kinase, and four from serum albumin protein. However, MRM could only detect four peptides (EVTEFAK, LVVITAGAR, FVIER and TVLGNFAAFVQK) that were consistently present in pork samples. In conclusion, meat species determination through a tandem mass spectrometry platform shows high potential in providing scientifically valid and reliable results even at peptide level. Besides, the specificity and selectivity offered by the proteomics approach also provide a robust platform for Halal authentication. Copyright © 2015 Elsevier Ltd. All rights reserved.
Carvalho, J J; Jerónimo, P C A; Gonçalves, C; Alpendurada, M F
2008-11-01
European Council Directive 98/83/EC on the quality of water intended for human consumption brought a new challenge for water-quality control routine laboratories, mainly on pesticides analysis. Under the guidelines of ISO/IEC 17025:2005, a multiresidue method was developed, validated, implemented in routine, and studied with real samples during a one-year period. The proposed method enables routine laboratories to handle a large number of samples, since 28 pesticides of 14 different chemical groups can be quantitated in a single procedure. The method comprises a solid-phase extraction step and subsequent analysis by liquid chromatography-mass spectrometry (LC-MS-MS). The accuracy was established on the basis of participation in interlaboratory proficiency tests, with encouraging results (majority |z-score| <2), and the precision was consistently analysed over one year. The limits of quantitation (below 0.050 microg L(-1)) are in agreement with the enforced threshold value for pesticides of 0.10 microg L(-1). Overall method performance is suitable for routine use according to accreditation rules, taking into account the data collected over one year.
Nakano, Yosuke; Konya, Yutaka; Taniguchi, Moyu; Fukusaki, Eiichiro
2017-01-01
d-Amino acids have recently attracted much attention in various research fields including medical, clinical and food industry due to their important biological functions that differ from l-amino acid. Most chiral amino acid separation techniques require complicated derivatization procedures in order to achieve the desirable chromatographic behavior and detectability. Thus, the aim of this research is to develop a highly sensitive analytical method for the enantioseparation of chiral amino acids without any derivatization process using liquid chromatography-tandem mass spectrometry (LC-MS/MS). By optimizing MS/MS parameters, we established a quantification method that allowed the simultaneous analysis of 18 d-amino acids with high sensitivity and reproducibility. Additionally, we applied the method to food sample (vinegar) for the validation, and successfully quantified trace levels of d-amino acids in samples. These results demonstrated the applicability and feasibility of the LC-MS/MS method as a novel, effective tool for d-amino acid measurement in various biological samples. Copyright © 2016 The Society for Biotechnology, Japan. Published by Elsevier B.V. All rights reserved.
Sanghvi, M; Ramamoorthy, A; Strait, J; Wainer, I W; Moaddel, R
2013-08-15
Due to the lack of sensitivity in current methods for the determination of fenoterol (Fen), a rapid LC-MS/MS method was developed for the determination of (R,R')-Fen and (R,R';S,S')-Fen in plasma and urine. The method was fully validated and was linear from 50pg/ml to 2000pg/ml for plasma and from 2.500ng/ml to 160ng/ml for urine with a lower limit of quantitation of 52.8pg/ml in plasma. The coefficient of variation was <15% for the high QC standards and <10% for the low QC standards in plasma and was <15% for the high and low QC standards in urine. The relative concentrations of (R,R')-Fen and (S,S')-Fen were determined using a chirobiotic T chiral stationary phase. The method was used to determine the concentration of (R,R')-Fen in plasma and urine samples obtained in an oral cross-over study of (R,R')-Fen and (R,R';S,S')-Fen formulations. The results demonstrated a potential pre-systemic enantioselective interaction in which the (S,S')-Fen reduces the sulfation of the active (R,R')-Fen. The data suggest that a non-racemic mixture of the Fen enantiomers may provide better bioavailability of the active (R,R')-Fen for use in the treatment of cardiovascular disease. Published by Elsevier B.V.
Hasegawa, Takashi; Takahashi, Kazunaga; Fukiwake, Tomohide; Saijo, Masaaki; Motoki, Yuji
2013-01-01
We developed a simple and rapid liquid chromatography/mass spectrometry (LC/MS) method for the enantiomeric determination of DOPA in dietary supplements containing Mucuna pruriens. L- and D-DOPA were ultrasonically extracted with 1% formic acid aqueous solution. The isolated extracts were analyzed by LC/MS using a Crownpak CR (-) column at 30℃. The mass spectrometer was operated in the positive mode of electrospray ionization, and the mobile phase was aqueous formic acid (pH 2.0). L-DOPA-ring-d3 was used as an internal standard. The method was validated for a dietary supplement spiked with L- and D-DOPA at 50 and 500 μg/g, respectively, and the recoveries of the DOPA enantiomers were between 97.5% and 101.3%. Relative standard deviation values of repeatability and intermediate precision were less than 7%. The method was applied to 14 dietary supplements. L-DOPA was detected in these supplements in the range of 0.88-12.8 mg/unit. D-DOPA was not detected.
Dried blood spot analysis of creatinine with LC-MS/MS in addition to immunosuppressants analysis.
Koster, Remco A; Greijdanus, Ben; Alffenaar, Jan-Willem C; Touw, Daan J
2015-02-01
In order to monitor creatinine levels or to adjust the dosage of renally excreted or nephrotoxic drugs, the analysis of creatinine in dried blood spots (DBS) could be a useful addition to DBS analysis. We developed a LC-MS/MS method for the analysis of creatinine in the same DBS extract that was used for the analysis of tacrolimus, sirolimus, everolimus, and cyclosporine A in transplant patients with the use of Whatman FTA DMPK-C cards. The method was validated using three different strategies: a seven-point calibration curve using the intercept of the calibration to correct for the natural presence of creatinine in reference samples, a one-point calibration curve at an extremely high concentration in order to diminish the contribution of the natural presence of creatinine, and the use of creatinine-[(2)H3] with an eight-point calibration curve. The validated range for creatinine was 120 to 480 μmol/L (seven-point calibration curve), 116 to 7000 μmol/L (1-point calibration curve), and 1.00 to 400.0 μmol/L for creatinine-[(2)H3] (eight-point calibration curve). The precision and accuracy results for all three validations showed a maximum CV of 14.0% and a maximum bias of -5.9%. Creatinine in DBS was found stable at ambient temperature and 32 °C for 1 week and at -20 °C for 29 weeks. Good correlations were observed between patient DBS samples and routine enzymatic plasma analysis and showed the capability of the DBS method to be used as an alternative for creatinine plasma measurement.
Zhang, Jie; Bai, Ruoshi; Zhou, Zhaojuan; Liu, Xingyu; Zhou, Jun
2017-04-01
A fully automated analytical method was developed and validated by this present study. The method was based on two-dimensional (2D) online solid-phase extraction liquid chromatography-tandem mass spectrometry (SPE-LC-MS/MS) to determine nine aromatic amines (AAs) in mainstream smoke (MSS) simultaneously. As a part of validation process, AAs yields for 16 top-selling commercial cigarettes from China market were evaluated by the developed method under both Health Canada Intensive (HCI) and ISO machine smoking regimes. The gas phase of MSS was trapped by 25 mL 0.6 M hydrochloric acid solution, while the particulate phase was collected on a glass fiber filter. Then, the glass fiber pad was extracted with hydrochloric acid solution in an ultrasonic bath. The extract was analyzed with 2D online SPE-LC-MS/MS. In order to minimize the matrix effects of sample on each analyte, two cartridges with different extraction mechanisms were utilized to cleanup disturbances of different polarity, which were performed by the 2D SPE. A phenyl-hexyl analytical column was used to achieve a chromatographic separation. Under the optimized conditions, the isomers of p-toluidine, m-toluidine and o-toluidine, 3-aminobiphenyl and 4-aminobiphenyl, and 1-naphthylamine and 2-naphthylamine were baseline separated with good peak shapes for the first time. The limits of detection for nine AAs ranged from 0.03 to 0.24 ng cig -1 . The recovery of the measurement of nine AAs was from 84.82 to 118.47%. The intra-day and inter-day precisions of nine AAs were less than 10 and 16%, respectively. Compared with ISO machine smoking regime, the AAs yields in MSS were 1.17 to 3.41 times higher under HCI machine smoking regime. Graphical abstract New method using online SPE-LC/MS/MS for analysis of aromatic amines in mainstream cigarette smoke.
Dolder, Patrick C; Liechti, Matthias E; Rentsch, Katharina M
2018-02-01
Lysergic acid diethylamide (LSD) is a widely used recreational drug. The aim of this study was to develop and validate a liquid chromatography tandem mass spectrometry (LC-MS/MS) method for the quantification of LSD, iso-LSD, 2-oxo-3-hydroxy LSD (O-H-LSD), and nor-LSD in plasma samples from 24 healthy subjects after controlled administration of 100 μg LSD in a clinical trial. In addition, metabolites that have been recently described in in vitro studies, including lysergic acid monoethylamide (LAE), lysergic acid ethyl-2-hydroxyethylamide (LEO), 2-oxo-LSD, trioxylated-LSD, and 13/14-hydroxy-LSD, should be identified. Separation of LSD and its metabolites was achieved on a reversed phase chromatography column after turbulent-flow online extraction. For the identification and quantification, a triple-stage quadrupole LC-MS/MS instrument was used. The validation data showed slight matrix effects for LSD, iso-LSD, O-H-LSD, or nor-LSD. Mean intraday and interday accuracy and precision were 105%/4.81% and 105%/4.35% for LSD, 98.7%/5.75% and 99.4%/7.21% for iso-LSD, 106%/4.54% and 99.4%/7.21% for O-H-LSD, and 107%/5.82% and 102%/5.88% for nor-LSD, respectively. The limit of quantification was 0.05 ng/mL for LSD, iso-LSD, and nor-LSD and 0.1 ng/mL for O-H-LSD. The limit of detection was 0.01 ng/mL for all compounds. The method described herein was accurate, precise, and the calibration range within the range of expected plasma concentrations. LSD was quantified in the plasma samples of the 24 subjects of the clinical trial, whereas iso-LSD, O-H-LSD, nor-LSD, LAE, LEO, 13/14-hydroxy-LSD, and 2-oxo-LSD could only sporadically be detected but were too low for quantification. © 2017 Wiley Periodicals, Inc.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Luo, Y; McShan, D; Matuszak, M
Purpose: NSCLC radiotherapy treatment is a trade-off between controlling the tumor while limiting radiation-induced toxicities. Here we identify hierarchical biophysical relationships that could simultaneously influence both local control (LC) and RP by using an integrated Bayesian Networks (BN) approach. Methods: We studied 79 NSCLC patients treated on prospective protocol with 56 cases of LC and 21 events of RP. Beyond dosimetric information, each patient had 193 features including 12 clinical factors, 60 circulating blood cytokines before and during radiotherapy, 62 microRNAs, and 59 single-nucleotide polymorphisms (SNPs). The most relevant biophysical predictors for both LC and RP were identified using amore » Markov blanket local discovery algorithm and the corresponding BN was constructed using a score-learning algorithm. The area under the free-response receiver operating characteristics (AU-FROC) was used for performance evaluation. Cross-validation was employed to guard against overfitting pitfalls. Results: A BN revealing the biophysical interrelationships jointly in terms of LC and RP was developed and evaluated. The integrated BN included two SNPs, one microRNA, one clinical factor, three pre-treatment cytokines, relative changes of two cytokines between pre and during-treatment, and gEUDs of the GTV (a=-20) and lung (a=1). On cross-validation, the AUC prediction of independent LC was 0.85 (95% CI: 0.75–0.95) and RP was 0.83 (0.73–0.92). The AU-FROC of the integrated BN to predict both LC/RP was 0.81 (0.71–0.90) based on 2000 stratified bootstrap, indicating minimal loss in joint prediction power. Conclusions: We developed a new approach for multiple outcome utility application in radiotherapy based on integrated BN techniques. The BN developed from large-scale retrospective data is able to simultaneously predict LC and RP in NSCLC treatments based on individual patient characteristics. The joint prediction is only slightly compromised compared to independent predictions. Our approach shows promise for use in clinical decision support system for personalized radiotherapy subject to multiple endpoints. These studies were supported by a grant from the NCI/NIH P01-CA59827.« less
Ni, Yang; Zhou, Ying; Xu, Mingzhen; He, Xiaomeng; Li, Huqun; Haseeb, Satter; Chen, Hui; Li, Weiyong
2015-03-25
A new method for simultaneous determination of phentermine and topiramate by liquid chromatography/electrospray tandem mass spectrometry (LC/MS/MS) operated in positive and negative ionization switching modes was developed and validated. Protein precipitation with acetonitrile was selected for sample preparation. Analyses were performed on a liquid chromatography system employing a Kromasil 60-5CN column (2.1 mm × 100 mm, 5 μm) and an isocratic elution with mixed solution of acetonitrile-20mM ammonium formate containing 0.3% formic acid (40:60, v/v), at a flow rate of 0.35 mL/min. Doxazosin mesylate and pioglitazone were used as the internal standard (IS) respectively for quantification. The determination was carried out on an API 4000 triple-quadrupole mass spectrometer operated in multiple reaction monitoring (MRM) mode using the following transitions monitored simultaneously: positive m/z 150.0/91.0 for phentermine, m/z 452.1/344.3 for doxazosin, and negative m/z 338.3/77.9 for topiramate, m/z 355.0/41.9 for pioglitazone. The method was validated to be linear over the concentration range of 1-800 ng mL(-1) for phentermine, 1-1000 ng mL(-1) for topiramate. Within- and between-day accuracy and precision of the validated method at three different concentration levels were within the acceptable limits of <15% at all concentrations. Blood samples were collected into heparinized tubes before and after administration. The simple and robust LC/MS/MS method was successfully applied for the simultaneous determination of phentermine and topiramate in a pharmacokinetic study in healthy male Chinese volunteers. Copyright © 2015 Elsevier B.V. All rights reserved.
Zhao, Yue; Liu, Guowen; Angeles, Aida; Hamuro, Lora L; Trouba, Kevin J; Wang, Bonnie; Pillutla, Renuka C; DeSilva, Binodh S; Arnold, Mark E; Shen, Jim X
2015-04-15
We have developed and fully validated a fast and simple LC-MS/MS assay to quantitate a therapeutic protein BMS-A in cynomolgus monkey serum. Prior to trypsin digestion, a recently reported sample pretreatment method was applied to remove more than 95% of the total serum albumin and denature the proteins in the serum sample. The pretreatment procedure simplified the biological sample prior to digestion, improved digestion efficiency and reproducibility, and did not require reduction and alkylation. The denatured proteins were then digested with trypsin at 60 °C for 30 min and the tryptic peptides were chromatographically separated on an Acquity CSH column (2.1 mm × 50 mm, 1.7 μm) using gradient elution. One surrogate peptide was used for quantitation and another surrogate peptide was selected for confirmation. Two corresponding stable isotope labeled peptides were used to compensate variations during LC-MS detection. The linear analytical range of the assay was 0.50-500 μg/mL. The accuracy (%Dev) was within ± 5.4% and the total assay variation (%CV) was less than 12.0% for sample analysis. The validated method demonstrated good accuracy and precision and the application of the innovative albumin removal sample pretreatment method improved both assay sensitivity and robustness. The assay has been applied to a cynomolgus monkey toxicology study and the serum sample concentration data were in good agreement with data generated using a quantitative ligand-binding assay (LBA). The use of a confirmatory peptide, in addition to the quantitation peptide, ensured the integrity of the drug concentrations measured by the method. Copyright © 2015 Elsevier B.V. All rights reserved.
De Kesel, Pieter M M; Lambert, Willy E; Stove, Christophe P
2015-11-01
Caffeine is the probe drug of choice to assess the phenotype of the drug metabolizing enzyme CYP1A2. Typically, molar concentration ratios of paraxanthine, caffeine's major metabolite, to its precursor are determined in plasma following administration of a caffeine test dose. The aim of this study was to develop and validate an LC-MS/MS method for the determination of caffeine and paraxanthine in hair. The different steps of a hair extraction procedure were thoroughly optimized. Following a three-step decontamination procedure, caffeine and paraxanthine were extracted from 20 mg of ground hair using a solution of protease type VIII in Tris buffer (pH 7.5). Resulting hair extracts were cleaned up on Strata-X™ SPE cartridges. All samples were analyzed on a Waters Acquity UPLC® system coupled to an AB SCIEX API 4000™ triple quadrupole mass spectrometer. The final method was fully validated based on international guidelines. Linear calibration lines for caffeine and paraxanthine ranged from 20 to 500 pg/mg. Precision (%RSD) and accuracy (%bias) were below 12% and 7%, respectively. The isotopically labeled internal standards compensated for the ion suppression observed for both compounds. Relative matrix effects were below 15%RSD. The recovery of the sample preparation procedure was high (>85%) and reproducible. Caffeine and paraxanthine were stable in hair for at least 644 days. The effect of the hair decontamination procedure was evaluated as well. Finally, the applicability of the developed procedure was demonstrated by determining caffeine and paraxanthine concentrations in hair samples of ten healthy volunteers. The optimized and validated method for determination of caffeine and paraxanthine in hair proved to be reliable and may serve to evaluate the potential of hair analysis for CYP1A2 phenotyping. Copyright © 2015 Elsevier B.V. All rights reserved.
Machado, J C; Lange, A D; Todeschini, V; Volpato, N M
2014-02-01
A dissolution method to analyze atorvastatin tablets using in vivo data for RP and test pilot (PB) was developed and validated. The appropriate conditions were determined after solubility tests using different media, and sink conditions were established. The conditions used were equipment paddle at 50 rpm and 900 mL of potassium phosphate buffer pH 6.0 as dissolution medium. In vivo release profiles were obtained from the bioequivalence study of RP and the generic candidate PB. The fraction of dose absorbed was calculated using the Loo-Riegelman method. It was necessary to use a scale factor of time similar to 6.0, to associate the values of absorbed fraction and dissolved fraction, obtaining an in vivo-in vitro correlation level A. The dissolution method to quantify the amount of drug dissolved was validated using high-performance liquid chromatography and ultraviolet spectrophotometry, and validated according to the USP protocol. The discriminative power of dissolution conditions was assessed using two different pilot batches of atorvastatin tablets (PA and PB) and RP. The dissolution test was validated and may be used as a discriminating method in quality control and in the development of the new formulations.
Munigunti, Ranjith; Calderón, Angela I
2012-09-15
Plasmodium falciparum (Pf) thioredoxin reductase (TrxR) catalyzes the reduction of thioredoxin disulfide (Trx-S(2)) to thioredoxin dithiol (Trx-(SH)(2)) that is essential for antioxidant defense mechanism and DNA synthesis in the parasite and is a validated drug target for new antimalarial agents. In this study, we have developed a liquid chromatography/mass spectrometry (LC/MS)-based functional assay to identify inhibitors of PfTrxR by quantifying the product formed (Trx-(SH)(2)) in the enzymatic reaction. Relative quantitation of the reaction product (intact Trx-(SH)(2)) was carried out using an Agilent 6520 QTOF mass spectrometer equipped with a positive mode electrospray ionization (ESI) source. The calibration curve prepared for Trx-(SH)(2) at concentrations ranging from 1.8 to 116.5 µg/mL was linear (R(2) >0.998). The limit of detection (LOD) and limit of quantification (LOQ) of Trx-(SH)(2) were at 0.45 and 1.8 µg/mL respectively. To validate the developed functional assay we have screened reference compounds 1, 2 and 3 for their PfTrxR inhibitory activity and ten natural compounds (at 10 μM) which were earlier identified as ligands of PfTrxR by a UF-LC/MS based binding assay. The developed LC/MS-based functional assay for identification of inhibitors of PfTrxR is a sensitive and reliable method that is also amendable for high-throughput format. This is the first representation of a relative quantitation of intact Trx-(SH)(2) using LC/MS. Copyright © 2012 John Wiley & Sons, Ltd.
Janssen, Marcel J W; Hendrickx, Ben H E; Habets-van der Poel, Carin D; van den Bergh, Joop P W; Haagen, Anton A M; Bakker, Jaap A
2010-12-01
The Precision(®) (Abbott Diabetes Care) point-of-care biosensor test strips are widely used by patients with diabetes and clinical laboratories for measurement of plasma β-hydroxybutyrate (β-HB) concentrations in capillary blood samples obtained by fingerstick. In the literature, this procedure has been validated only against the enzymatic determination of β-HB in venous plasma, i.e., the method to which the Precision(®) has been calibrated. In this study, the Precision(®) Xceed was compared to a methodologically different and superior procedure: determination of β-HB by liquid chromatography tandem-mass spectrometry (LC-MS/MS) in capillary blood spots. Blood spots were obtained from the same fingerstick sample from out of which Precision(®) measurements were performed. Linearity was tested by adding varying amounts of standard to an EDTA venous whole blood matrix. The Precision(®) was in good agreement with LC-MS/MS within the measuring range of 0.0-6.0 mmol/L (Passing and Bablok regression: slope=1.20 and no significant intercept, R=0.97, n=59). Surprisingly, the Precision(®) showed non-linearity and full saturation at concentrations above 6.0 mmol/L, which were confirmed by a standard addition experiment. Results obtained at the saturation level varied between 3.0 and 6.5 mmol/L. The Precision(®) β-HB test strips demonstrate good comparison with LC-MS/MS. Inter-individual variation around the saturation level, however, is large. Therefore, we advise reporting readings above 3.0 as >3.0 mmol/L. The test is valid for use in the clinically relevant range of 0.0-3.0 mmol/L.
El-Geidie, Ahmed Abdel-Raouf
2011-08-01
The intraoperative use of endoscopic retrograde cholangiopancreatography (ERCP) during laparoscopic cholecystectomy (LC) is a safe, single-stage option for the management of concomitant gallstones (GS) and common bile duct stones (CBDS). This study aims to compare between 2 techniques of combined laparoendoscopic management, which are laparoendoscopic Rendez-vous (LC/LERV) technique and standard ERCP after the completion of LC intraoperative endoscopic sphincterotomy (IOES). Patients with GS and suspected CBDS were included. They were divided into 2 groups; LC/LERV and LC/IOES. Both groups were compared for failure of endoscopic sphincterotomy/stone extraction, operative time, conversion rate, mortality/morbidity, and length of hospital stay. Between October 2007 and February 2010, 98 patients with GS and CBDS were eligible for inclusion in the study. They were prospectively randomized into 2 groups; LC/LERV (N=45) and LC/IOES (N=53). There were no differences in preoperative parameters between both groups. There was a significant difference in operative time (shorter for LC/IOES). No difference was noted in success/failure rate, post-ERCP pancreatitis. Both Standard ERCP after the completion of LC and LC/LERV are valid single-session management for CBD stones, but LC-ERCP may be preferred.
Eichhold, Thomas H; McCauley-Myers, David L; Khambe, Deepa A; Thompson, Gary A; Hoke, Steven H
2007-01-17
A method for the simultaneous determination of dextromethorphan (DEX), dextrorphan (DET), and guaifenesin (GG) in human plasma was developed, validated, and applied to determine plasma concentrations of these compounds in samples from six clinical pharmacokinetic (PK) studies. Semi-automated liquid handling systems were used to perform the majority of the sample manipulation including liquid/liquid extraction (LLE) of the analytes from human plasma. Stable-isotope-labeled analogues were utilized as internal standards (ISTDs) for each analyte to facilitate accurate and precise quantification. Extracts were analyzed using gradient liquid chromatography coupled with tandem mass spectrometry (LC-MS/MS). Use of semi-automated LLE with LC-MS/MS proved to be a very rugged and reliable approach for analysis of more than 6200 clinical study samples. The lower limit of quantification was validated at 0.010, 0.010, and 1.0 ng/mL of plasma for DEX, DET, and GG, respectively. Accuracy and precision of quality control (QC) samples for all three analytes met FDA Guidance criteria of +/-15% for average QC accuracy with coefficients of variation less than 15%. Data from the thorough evaluation of the method during development, validation, and application are presented to characterize selectivity, linearity, over-range sample analysis, accuracy, precision, autosampler carry-over, ruggedness, extraction efficiency, ionization suppression, and stability. Pharmacokinetic data are also provided to illustrate improvements in systemic drug and metabolite concentration-time profiles that were achieved by formulation optimization.
Koželj, Gordana; Perharič, Lucija; Stanovnik, Lovro; Prosen, Helena
2014-08-05
A liquid chromatography-tandem mass spectrometry (LC-MS/MS) method for the determination of atropine and scopolamine in 100μL human plasma was developed and validated. Sample pretreatment consisted of protein precipitation with acetonitrile followed by a concentration step. Analytes and levobupivacaine (internal standard) were separated on a Zorbax XDB-CN column (75mm×4.6mm i.d., 3.5μm) with gradient elution (purified water, acetonitrile, formic acid). The triple quadrupole MS was operated in ESI positive mode. Matrix effect was estimated for deproteinised plasma samples. Selected reaction monitoring (SRM) was used for quantification in the range of 0.10-50.00ng/mL. Interday precision for both tropanes and intraday precision for atropine was <10%, intraday precision for scopolamine was <14% and <18% at lower limit of quantification (LLOQ). Mean interday and intraday accuracies for atropine were within ±7% and for scopolamine within ±11%. The method can be used for determination of therapeutic and toxic levels of both compounds and has been successfully applied to a study of pharmacodynamic and pharmacokinetic properties of tropanes, where plasma samples of volunteers were collected at fixed time intervals after ingestion of a buckwheat meal, spiked with five low doses of tropanes. Copyright © 2014 Elsevier B.V. All rights reserved.
Cordero, Chiara; Canale, Francesca; Del Rio, Daniele; Bicchi, Carlo
2009-11-01
The present study is focused on flavan-3-ols characterizing the antioxidant properties of fermented tea (Camellia sinensis). These bioactive compounds, object of nutritional claims in commercial products, should be quantified with rigorous analytical procedures whose accuracy and precision have been stated with a certain level of confidence. An HPLC-UV/DAD method, able to detect and quantify flavan-3-ols in infusions and ready-to-drink teas, has been developed for routine analysis and validated by characterizing several performance parameters. The accuracy assessment has been run through a series of LC-MS/MS analyses. Epigallocatechin, (+)-catechin, (-)-epigallocatechingallate, (-)-epicatechin, (-)-gallocatechingallate, (-)-epicatechingallate, and (-)-catechingallate were chosen as markers of the polyphenolic fraction. Quantitative results showed that samples obtained from tea leaves infusion were richer in polyphenolic antioxidants than those obtained through other industrial processes. The influence of shelf-life and packaging material on the flavan-3-ols content was also considered; markers decreased, with an exponential trend, as a function of time within the shelf life while packaging materials demonstrated to influence differently the flavan-3-ol fraction composition over time. The method presented here provides quantitative results with a certain level of confidence and is suitable for a routine quality control of iced teas whose antioxidant properties are object of nutritional claim.
Kumar, Ajay; Monif, Tausif; Khuroo, Arshad; Sasmal, Dinakar; Goswami, Dipanjan; Lahkar, Vijay Kumar
2011-06-01
LC- ESI- MS/MS simultaneous bioanalytical method was developed to determine acitretin and its metabolite isoacitretin in human plasma using acitretin-d3 used as the internal standard for both analytes. The compounds were extracted using protein precipitation coupled with liquid-liquid extraction with flash freezing technique. Negative mass transitions (m/z) of acitretin, isoacitretin and acitretin-d3 were detected in multiple reactions monitoring (MRM) mode at 325.4 → 266.3, 325.2 → 266.1 and 328.3 → 266.3, respectively, with a turbo ion spray interface. The chromatographic separation was achieved on an Ascentis-RP amide column (4.6 × 150 mm, 5 µm) with mobile phase delivered in isocratic mode. The method was validated over a concentration range of 1.025-753.217 ng/mL for acitretin and 0.394-289.234 ng/mL for isoacitretin with a limit of quantification of 1.025 and 0.394 ng/mL. The intra-day and inter-day precisions were below 8.1% for acitretin and below 13.8% for isoacitretin, while accuracy was within ±7.0 and ±10.6% respectively. For the first time, the best possible conditions for plasma stability of acitretin and isoacitretin are presented and discussed with application to clinical samples. Copyright © 2010 John Wiley & Sons, Ltd.
McDonald, Mark; Malone, Edward; McBride, John
2010-01-01
A novel and rapid method was developed and validated for the confirmation of endogenous and synthetic hormones in animal serum using LC/MS/MS. Detection of 17 beta-estradiol and beta-testosterone below the respective European Union-recommended levels of 0.1 and 0.5 microg/L was achieved, as was a required performance level of 0.1 microg/L for 17 alpha-estradiol and 0.5 microg/L for 17 alpha-testosterone, medroxyprogesterone-17-acetate, and progesterone. The method was established with dilution of serum followed by ion-exchange SPE, LC separation and MS detection with electrospray ionization, selected reaction monitoring, and positivelnegative switching. Two characteristic transitions were monitored for each analyte. The method was applied to bovine, ovine, porcine, equine, and avian samples and validated according to European Commission Decision 2002/657/EC and accepted for ISO/IEC 17025:2005 accreditation. An extended calibration curve allows naturally occurring levels of endogenous hormones to be quantified. Recoveries ranged from 97.3% for 17 alpha-testosterone to 102.0% for 17 alpha-estradiol. The decision limit CCalpha ranged from 0.02 microg/L for 17 alpha- and beta-estradiol to 0.12 microg/L for progesterone. Detection capability CCbeta ranged from 0.03 microg/L for 17 a-estradiol to 0.20 microg/L for progesterone.
Hogendoorn, E A; Westhuis, K; Dijkman, E; Heusinkveld, H A; den Boer, A C; Evers, E A; Baumann, R A
1999-10-08
The coupled-column (LC-LC) configuration consisting of a 3 microm C18 column (50 x 4.6 mm I.D.) as the first column and a 5 microm C18 semi-permeable-surface (SPS) column (150 x 4.6 mm I.D.) as the second column appeared to be successful for the screening of acidic pesticides in surface water samples. In comparison to LC-LC employing two C18 columns, the combination of C18/SPS-C18 significantly decreased the baseline deviation caused by the hump of the co-extracted humic substances when using UV detection (217 nm). The developed LC-LC procedure allowed the simultaneous determination of the target analytes bentazone and bromoxynil in uncleaned extracts of surface water samples to a level of 0.05 microg/l in less than 15 min. In combination with a simple solid-phase extraction step (200 ml of water on a 500 mg C18-bonded silica) the analytical procedure provides a high sample throughput. During a period of about five months more than 200 ditch-water samples originating from agricultural locations were analyzed with the developed procedure. Validation of the method was performed by randomly analyzing recoveries of water samples spiked at levels of 0.1 microg/l (n=10), 0.5 microg/l (n=7) and 2.5 microg/l (n=4). Weighted regression of the recovery data showed that the method provides overall recoveries of 95 and 100% for bentazone and bromoxynil, respectively, with corresponding intra-laboratory reproducibilities of 10 and 11%, respectively. Confirmation of the analytes in part of the samples extracts was carried out with GC-negative ion chemical ionization MS involving a derivatization step with bis(trifluoromethyl)benzyl bromide. No false negatives or positives were observed.
Zheng, Shirui; Ma, Zhiyuan; Han, Haixia; Ye, Jianfeng; Wang, Ruwei; Cai, Sheng; Zhou, Hui; Yu, Lushan; Zeng, Su; Jiang, Huidi
2014-07-01
Flavonoids are a group of important naturally occurring polyphenolic compounds with a wide range of biological effects. In this study, a sensitive liquid chromatography tandem mass spectrometry method was developed to simultaneously determine multiple active flavonoids, including quercetin (Que), kaempferol (Kae), apigenin (Api), isorhamnetin (Iso), luteolin (Lut), and naringenin (Nar), in rat plasma. To achieve a satisfied peak shape and LC separation, formic acid with the concentration between 0.05 and 0.2%, or in some case 5%, was generally used to acidify the LC mobile phase in reported studies. Here we found that even 0.05% formic acid could lead to strong mass signal suppression, and the absence of formic acid could reverse the signal suppression but cause serious peak tailing. There is an irreconcilable contradiction between liquid chromatography (LC) and mass spectrometry (MS). In order to simultaneously satisfy LC and MS, LC mobile phase with 0.00075% formic acid and post column mobile phase adjustment with 0.0677% ammonium solution in isopropanol were applied. Compared with the conventional method with mobile phase containing 0.05% formic acid, the mass signal response of Que, Kae, Api, Iso, Lut, Nar, and Oka increased 26.2, 18.6, 13.6, 23.5, 17.5, 15.6 and 15.4 fold, respectively. In addition, the post column mobile phase addition exhibited the better peak shape for the reduction of analytes longitudinal diffusion. The method has been fully validated according to FDA guidelines within the linear range between 0.328 ng mL⁻¹ and 168 ng mL⁻¹, and successfully applied to a pilot pharmacokinetic study of rats after administering 5.43 g kg⁻¹ Pollen of Brassica campestris. Copyright © 2014 Elsevier B.V. All rights reserved.
The NISTmAb tryptic peptide spectral library for monoclonal antibody characterization.
Dong, Qian; Liang, Yuxue; Yan, Xinjian; Markey, Sanford P; Mirokhin, Yuri A; Tchekhovskoi, Dmitrii V; Bukhari, Tallat H; Stein, Stephen E
2018-04-01
We describe the creation of a mass spectral library composed of all identifiable spectra derived from the tryptic digest of the NISTmAb IgG1κ. The library is a unique reference spectral collection developed from over six million peptide-spectrum matches acquired by liquid chromatography-mass spectrometry (LC-MS) over a wide range of collision energy. Conventional one-dimensional (1D) LC-MS was used for various digestion conditions and 20- and 24-fraction two-dimensional (2D) LC-MS studies permitted in-depth analyses of single digests. Computer methods were developed for automated analysis of LC-MS isotopic clusters to determine the attributes for all ions detected in the 1D and 2D studies. The library contains a selection of over 12,600 high-quality tandem spectra of more than 3,300 peptide ions identified and validated by accurate mass, differential elution pattern, and expected peptide classes in peptide map experiments. These include a variety of biologically modified peptide spectra involving glycosylated, oxidized, deamidated, glycated, and N/C-terminal modified peptides, as well as artifacts. A complete glycation profile was obtained for the NISTmAb with spectra for 58% and 100% of all possible glycation sites in the heavy and light chains, respectively. The site-specific quantification of methionine oxidation in the protein is described. The utility of this reference library is demonstrated by the analysis of a commercial monoclonal antibody (adalimumab, Humira®), where 691 peptide ion spectra are identifiable in the constant regions, accounting for 60% coverage for both heavy and light chains. The NIST reference library platform may be used as a tool for facile identification of the primary sequence and post-translational modifications, as well as the recognition of LC-MS method-induced artifacts for human and recombinant IgG antibodies. Its development also provides a general method for creating comprehensive peptide libraries of individual proteins.
The NISTmAb tryptic peptide spectral library for monoclonal antibody characterization
Dong, Qian; Liang, Yuxue; Yan, Xinjian; Markey, Sanford P.; Mirokhin, Yuri A.; Tchekhovskoi, Dmitrii V.; Bukhari, Tallat H.; Stein, Stephen E.
2018-01-01
ABSTRACT We describe the creation of a mass spectral library composed of all identifiable spectra derived from the tryptic digest of the NISTmAb IgG1κ. The library is a unique reference spectral collection developed from over six million peptide-spectrum matches acquired by liquid chromatography-mass spectrometry (LC-MS) over a wide range of collision energy. Conventional one-dimensional (1D) LC-MS was used for various digestion conditions and 20- and 24-fraction two-dimensional (2D) LC-MS studies permitted in-depth analyses of single digests. Computer methods were developed for automated analysis of LC-MS isotopic clusters to determine the attributes for all ions detected in the 1D and 2D studies. The library contains a selection of over 12,600 high-quality tandem spectra of more than 3,300 peptide ions identified and validated by accurate mass, differential elution pattern, and expected peptide classes in peptide map experiments. These include a variety of biologically modified peptide spectra involving glycosylated, oxidized, deamidated, glycated, and N/C-terminal modified peptides, as well as artifacts. A complete glycation profile was obtained for the NISTmAb with spectra for 58% and 100% of all possible glycation sites in the heavy and light chains, respectively. The site-specific quantification of methionine oxidation in the protein is described. The utility of this reference library is demonstrated by the analysis of a commercial monoclonal antibody (adalimumab, Humira®), where 691 peptide ion spectra are identifiable in the constant regions, accounting for 60% coverage for both heavy and light chains. The NIST reference library platform may be used as a tool for facile identification of the primary sequence and post-translational modifications, as well as the recognition of LC-MS method-induced artifacts for human and recombinant IgG antibodies. Its development also provides a general method for creating comprehensive peptide libraries of individual proteins. PMID:29425077
Tiryaki, Osman
2016-10-02
This study was undertaken to validate the "quick, easy, cheap, effective, rugged and safe" (QuEChERS) method using Golden Delicious and Starking Delicious apple matrices spiked at 0.1 maximum residue limit (MRL), 1.0 MRL and 10 MRL levels of the four pesticides (chlorpyrifos, dimethoate, indoxacarb and imidacloprid). For the extraction and cleanup, original QuEChERS method was followed, then the samples were subjected to liquid chromatography-triple quadrupole mass spectrometry (LC-MS/MS) for chromatographic analyses. According to t test, matrix effect was not significant for chlorpyrifos in both sample matrices, but it was significant for dimethoate, indoxacarb and imidacloprid in both sample matrices. Thus, matrix-matched calibration (MC) was used to compensate matrix effect and quantifications were carried out by using MC. The overall recovery of the method was 90.15% with a relative standard deviation of 13.27% (n = 330). Estimated method detection limit of analytes blew the MRLs. Some other parameters of the method validation, such as recovery, precision, accuracy and linearity were found to be within the required ranges.
Bioassay of safinamide in biological fluids of humans and various animal species.
Dal Bo, Lorenzo; Mazzucchelli, Paolo; Fibbioli, Monia; Marzo, Antonio
2006-01-01
This paper describes three methods to bioassay safinamide (CAS 133865-89-1) in biological fluids of humans and laboratory animals for pharmacokinetic, toxicokinetic and bioavailability studies. Two methods profited from liquid chromatography tandem mass spectrometry (LC-MS-MS) system, one (micro bioassay) working in the low dynamic range 0.5-20 ng/ml, the other in the range 20-6000 ng/ml. A third method used high-performance liquid chromatrography with fluorimetric detection (HPLC-FD), working in the dynamic range 20-1000 ng/ml. All the three methods were validated in compliance with the accreditated views on analytical bioassays. The shorter run time (5.5 min vs 16 min) has led the authors to prefer the two LC-MS-MS methods to the HPLC-FD bioassay, even if all the performances of the three methods were excellent. The methods described in this paper were and are still now extensively used to assay safinamide in more than 10,000 specimens of biological fluids from humans and laboratory animals in the development program of the drug. Main pharmacokinetic results obtained in various Phase I trials on healthy volunteers are briefly reported.
Kamel, Alaa
2010-05-26
An analytical method was refined for the extraction and determination of neonicotinoid pesticide residues and their metabolites in honey bees and bee products. Samples were extracted with 2% triethylamine (TEA) in acetonitrile (ACN) followed by salting out, solid phase extraction (SPE) cleanup, and detection using liquid chromatography-tandem mass spectrometry (LC-MS/MS). The method was validated in triplicate at three fortification concentrations in each matrix. Good recoveries were observed for most analytes and ranged between 70 and 120% with relative standard deviations between replicates of <20% in most cases. The method limits of detection were 0.2 ng/g for the parent neonicotinoid pesticides and ranged between 0.2 and 15 ng/g for the neonicotinoid metabolites. This refined method provides lower detection limits and improved recovery of neonicotinoids and their metabolites, which will help researchers evaluate subchronic effects of these pesticides, address data gaps related to colony collapse disorder (CCD), and determine the role of pesticides in pollinator decline.
Multi-mycotoxin stable isotope dilution LC-MS/MS method for Fusarium toxins in beer.
Habler, Katharina; Gotthardt, Marina; Schüler, Jan; Rychlik, Michael
2017-03-01
A stable isotope dilution LC-MS/MS multi-mycotoxin method was developed for 12 different Fusarium toxins including modified mycotoxins in beer (deoxynivalenol-3-glucoside, deoxynivalenol, 3-acetyldeoxynivalenol, 15-acetyl-deoxynivalenol, HT2-toxin, T2-toxin, enniatin B, B1, A1, A, beauvericin and zearalenone). As sample preparation and purification of beer a combined solid phase extraction for trichothecenes, enniatins, beauvericin and zearalenone was firstly developed. The validation of the new method gave satisfying results: intra-day and inter-day precision and recoveries were 1-5%, 2-8% and 72-117%, respectively. In total, 61 different organic and conventional beer samples from Germany and all over the world were analyzed by using the newly developed multi-mycotoxin method. In summary, deoxynivalenol, deoxynivalenol-3-glucoside, 3-acetyldeoxynivaleneol and enniatin B were quantified in rather low contents in the investigated beer samples. None of the other monitored Fusarium toxins like 15-acetyldeoxynivalenol, HT2- and T2-toxin, zearalenone, enniatin B1, A1, A or beauvericin were detectable. Copyright © 2016 Elsevier Ltd. All rights reserved.
Economou, Anastasios; Petraki, Olympia; Tsipi, Despina; Botitsi, Eleni
2012-08-15
This work reports a sensitive liquid chromatography-tandem mass spectrometry (LC-MS/MS) method for identification and quantification of seven sulfonamides, trimethoprim and dapsone in honey. The method is based on a solid-phase extraction (SPE) step of the target analytes with Oasis HLB cartridges after acidic hydrolysis of the honey sample to liberate the sugar-bound sulfonamides. Analysis was performed using liquid chromatography-tandem mass spectrometry (LC-MS/MS) in the positive electro-spray ionization (ESI) mode with two different isotopically labeled internal standards with the view to improve the quantitative performance of the method. The method validation has been performed according to the Commission Decision 2002/657/EC; the average recoveries, measured at three concentration levels (1.5, 2.5 and 5.0 μg kg(-1)), have been estimated in the range 70 to 106% while the respective % relative standard deviations of the within-laboratory reproducibility ranged from 6 to 18%. Mean values of the expanded uncertainties calculated were in the range 22-41% at the 99% confidence level. Decision limit (CCα) and detection capability (CCβ) values were in the ranges 0.4-0.9 and 0.7-1.4 μg kg(-1), respectively. Matrix effects have been investigated demonstrating a moderate signal suppression/enhancement for most of the target compounds. The method described has been successfully applied to the analysis of honey samples; sulfamethoxazole, sulfathiazole and trimethoprim were detected in some cases. Copyright © 2012 Elsevier B.V. All rights reserved.
Maia, Alexandra S; Ribeiro, Ana R; Amorim, Catarina L; Barreiro, Juliana C; Cass, Quezia B; Castro, Paula M L; Tiritan, Maria Elizabeth
2014-03-14
Antibiotics are a therapeutic class widely found in environmental matrices and extensively studied due to its persistence and implications for multi-resistant bacteria development. This work presents an integrated approach of analytical multi-techniques on assessing biodegradation of fluorinated antibiotics at a laboratory-scale microcosmos to follow removal and formation of intermediate compounds. Degradation of four fluoroquinolone antibiotics, namely Ofloxacin (OFL), Norfloxacin (NOR), Ciprofloxacin (CPF) and Moxifloxacin (MOX), at 10 mg L(-1) using a mixed bacterial culture, was assessed for 60 days. The assays were followed by a developed and validated analytical method of LC with fluorescence detection (LC-FD) using a Luna Pentafluorophenyl (2) 3 μm column. The validated method demonstrated good selectivity, linearity (r(2)>0.999), intra-day and inter-day precisions (RSD<2.74%) and accuracy. The quantification limits were 5 μg L(-1) for OFL, NOR and CPF and 20 μg L(-1) for MOX. The optimized conditions allowed picturing metabolites/transformation products formation and accumulation during the process, stating an incomplete mineralization, also shown by fluoride release. OFL and MOX presented the highest (98.3%) and the lowest (80.5%) extent of degradation after 19 days of assay, respectively. A representative number of samples was selected and analyzed by LC-MS/MS with triple quadrupole and the molecular formulas were confirmed by a quadruple time of flight analyzer (QqTOF). Most of the intermediates were already described as biodegradation and/or photodegradation products in different conditions; however unknown metabolites were also identified. The microbial consortium, even when exposed to high levels of FQ, presented high percentages of degradation, never reported before for these compounds. Copyright © 2014 Elsevier B.V. All rights reserved.
LC-MS/MS assay for the quantitation of the ATR kinase inhibitor VX-970 in human plasma.
Kiesel, Brian F; Scemama, Jonas; Parise, Robert A; Villaruz, Liza; Iffland, Andre; Doyle, Austin; Ivy, Percy; Chu, Edward; Bakkenist, Christopher J; Beumer, Jan H
2017-11-30
DNA damaging chemotherapy and radiation are widely used standard-of-care modalities for the treatment of cancer. Nevertheless, the outcome for many patients remains poor and this may be attributed, at least in part, to highly effective DNA repair mechanisms. Ataxia-telangiectasia mutated and Rad3-related (ATR) is a key regulator of the DNA-damage response (DDR) that orchestrates the repair of damaged replication forks. ATR is a serine/threonine protein kinase and ATR kinase inhibitors potentiate chemotherapy and radiation. The ATR kinase inhibitor VX-970 (NSC 780162) is in clinical development in combination with primary cytotoxic agents and as a monotherapy for tumors harboring specific mutations. We have developed and validated an LC-MS/MS assay for the sensitive, accurate and precise quantitation of VX-970 in human plasma. A dilute-and-shoot method was used to precipitate proteins followed by chromatographic separation with a Phenomenex Polar-RP 80Å (4μm, 50×2mm) column and a gradient acetonitrile-water mobile phase containing 0.1% formic acid from a 50μL sample volume. Detection was achieved using an API 4000 mass spectrometer using electrospray positive ionization mode. The assay was linear from 3 to 5,000ng/mL, proved to be accurate (94.6-104.2%) and precise (<8.4% CV), and fulfilled criteria from the FDA guidance for bioanalytical method validation. This LC-MS/MS assay will be a crucial tool in defining the clinical pharmacokinetics and pharmacology of VX-970 as it progresses through clinical development. Copyright © 2017 Elsevier B.V. All rights reserved.
Yuan, Yin; Zhou, Xuan; Li, Jian; Ye, Suofu; Ji, Xiwei; Li, Liang; Zhou, Tianyan; Lu, Wei
2015-04-01
In the current study, a simple, sensitive and rapid analytical method for the determination of dexamethasone was developed and applied to a pharmacokinetic study in nude mice. Using testosterone as an internal standard, a liquid chromatography-tandem mass spectrometry (LC-MS/MS) approach after one-step precipitation with acetonitrile was validated and used to determine the concentrations of dexamethasone in nude mice plasma. The method utilized a simple isocratic reverse phase separation over a Dionex C18 column with a mobile phase composed of acetonitrile-water (40:60, v/v). The analyte was detected by a triple quadrupole tandem mass spectrometer via electrospray and multiple reaction monitoring was employed to select both dexamethasone at m/z 393.0/147.1 and testosterone at m/z 289.5/97.3 in the positive ion mode. The calibration curves were linear (r >0.99) ranging from 2.5 to 500 ng/mL with a lower limit of quantitation of 2.5 ng/mL. The relative standard deviation ranged from 1.69 to 9.22% while the relative error ranged from -1.92 to -8.46%. This method was successfully applied to a preclinical pharmacokinetic study of dexamethasone and its pharmacokinetics was characterized by a two-compartment model with first-order absorption in female nude mice. Copyright © 2014 John Wiley & Sons, Ltd.
Bystrowska, Beata; Smaga, Irena; Tyszka-Czochara, Małgorzata; Filip, Małgorzata
2014-05-01
In recent years, a potential participation of endocannabinoids (eCBs) and related endocannabinoid-like molecules, including N-acylethanolamines (NAEs), in the physiological and pathophysiological processes has been highlighted, whereas measurement of their levels still remains difficult. The aim of this study was to develop a bioanalytical method that would enable researchers to simultaneously determine quantitatively eCBs (anandamide - AEA and 2-arachidonoylglycerol - 2-AG) and NAEs (oleoylethanolamide or oleoylethanolamine - OEA, palmitoylethanolamide or palmitoylethanolamine - PEA and linoleoylethanolamide or linoleoylethanolamine - LEA) in the rat brain. The analytical problems with analysis and possible solutions have been also shown. The methodology for quantifying eCBs/NAEs by means of a sensitive and selective liquid chromatography tandem mass spectrometry (LC-MS/MS) with electrospray positive ionization and multiple reaction monitoring (MRM) mode was developed and validated. Analytical problems with analyzed compounds were estimated. Reasonably high precision and accuracy of the method were demonstrated in the validation process. The method is linear up to 200 ng/g for AEA, OEA, PEA and LEA and up to 100 μg/g for 2-AG, while the quantification limit reaches 0.2 ng/g and 0.8 μg/g, respectively. Simplicity and rapidity of the assay allows analyzing many samples on a routine basis. This article presents the new procedure applied to the analysis of brain tissues.
Leigh, Jessica K; MacMahon, Shaun
2016-12-14
A method was developed for the extraction of fatty acid esters of 3-chloro-1,2-propanediol (3-MCPD) and glycidol from infant formula, followed by quantitative analysis of the extracts using liquid chromatography-tandem mass spectrometry (LC-MS/MS). These process-induced chemical contaminants are found in refined vegetable oils, and studies have shown that they are potentially carcinogenic and/or genotoxic, making their presence in edible oils (and processed foods containing these oils) a potential health risk. The extraction procedure involves a liquid-liquid extraction, where powdered infant formula is dissolved in water and extracted with ethyl acetate. Following shaking, centrifugation, and drying of the organic phase, the resulting fat extract is cleaned-up using solid-phase extraction and analyzed by LC-MS/MS. Method performance was confirmed by verifying the percent recovery of each 3-MCPD and glycidyl ester in a homemade powdered infant formula reference material. Average ester recoveries in the reference material ranged from 84.9 to 109.0% (0.6-9.5% RSD). The method was also validated by fortifying three varieties of commercial infant formulas with a 3-MCPD and glycidyl ester solution. Average recoveries of the esters across all concentrations and varieties of infant formula ranged from 88.7 to 107.5% (1.0-9.5% RSD). Based on the validation results, this method is suitable for producing 3-MCPD and glycidyl ester occurrence data in all commercially available varieties of infant formula.
Matus, Johanna L; Boison, Joe O
2016-05-01
A new and sensitive multi-residue liquid chromatography-tandem mass spectrometry (LC-MS/MS) and liquid chromatography-quadrupole time-of-flight-mass spectrometry (LC-QToF-MS) method was developed and validated for the determination and confirmation of residues of 17 anticoccidials, plus free ractopamine in poultry muscle and liver, and bovine muscle, liver, and kidney tissues. The 17 anticoccidials are lasalocid, halofuginone, narasin, monensin, semduramicin, ethopabate, robenidine, buquinolate, toltrazuril as its sulfone metabolite, maduramicin, salinomycin, diclazuril, amprolium, decoquinate, dinitolmide, clopidol, and the nicarbazin metabolite DNC (N,N1-bis(4-nitrophenyl)urea). The analytes were extracted and cleaned up within a 3-hour period by simply extracting the analytes into a solvent mixture with salts followed by centrifugation, dilution, and filtration. The validated method was used in a pilot study for the analysis of 173 samples that included quail liver, bovine kidney, liver, muscle, and horse muscle. The predominant residues found in this study were monensin, ractopamine, and lasalocid. The results of this pilot study showed that this new method is applicable to real samples, and is fit for use in a regulatory testing programme. © 2016 Her Majesty the Queen in Right of Canada. Drug Testing and Analysis. © 2016 John Wiley & Sons, Ltd. © 2016 Her Majesty the Queen in Right of Canada. Drug Testing and Analysis. © 2016 John Wiley & Sons, Ltd.
Asea, Philip E; MacNeil, James D; Boison, Joe O
2006-01-01
A method was developed and validated to screen for residues of the thyreostatic drugs, tapazole (TAP), mercaptobenzimidazole (MBI), thiouracil (TU), methylthiouracil (MTU), propylthiouracil (PrTU), and phenylthiouracil (PhTU) in bovine, equine, ovine, and porcine thyroid and muscle tissues at concentrations > or = 5 ng/g using 2-methoxy-mercaptobenzimidazole (MeMBI) and dimethylthiouracil (DMTU) as internal standards. In this method, the drugs were solvent extracted from thyroid and muscle tissue and cleaned up on an amino-propyl solid-phase extraction (SPE) cartridge. The unretained fraction containing TAP and MBI and the internal standard, MeMBI, was collected as Fraction 1. The retained fraction containing TU, MTU, PrTU, PhTU, and the internal standard, DMTU, was eluted with 3% acetic acid-isopropanol as Fraction 2. Fraction 1 was further cleaned up on an alumina B SPE cartridge and analyzed by gradient elution on a C18 high-performance liquid chromatography (HPLC) column with ultraviolet detection at wavelengths of 255 and 300 nm. Fraction 2 was taken to dryness, derivatized with 4-chloro-7-nitrobenzo-2-furazan at pH 8, and analyzed by gradient elution on a C18 LC column with mass spectrometry (MS) detection. Any "presumptive positive" test results were submitted for further analysis by LC/MS/MS. The validated method was applied to the analysis of over 300 thyroid tissue samples.
Tölgyesi, Ádám; Stroka, Joerg; Tamosiunas, Vytautas; Zwickel, Theresa
2015-01-01
Alternaria toxins and citrinin are mycotoxins produced by fungi growing on different raw materials and agricultural commodities. Maximum levels of these toxins in foods are currently under consideration by the European Commission as a risk management measure. In this study, a new quantitative method is described for the determination of five Alternaria toxins and citrinin in tomato and tomato juice samples based on LC-MS/MS detection. Samples were extracted with pure methanol, followed by a derivatisation step with 2,4-dinitrophenylhydrazine to improve the determination of tenuazonic acid and to decrease the wide polarity difference between the compounds of interest. Samples were purified on hydrophilic-modified styrene polymer solid-phase extraction cartridges. High-performance liquid chromatographic columns packed with different core–shell materials were tested for the separation of toxins and a C-18 phase was in the final method applied to achieve sufficient separation of all relevant analytes. A key element of this approach was to prove successful transferability of the method to three different triple quadrupole mass spectrometers. A full single laboratory method validation was performed on two LC-MS/MS systems and performance characteristics met the predefined requirements. Moreover, the method was used in an international proficiency test and the satisfactory z-scores obtained (−0.1 to 0.8 in tomato juice samples) demonstrated the reliability of the approach described. The method will be validated in an inter-laboratory collaborative study and if the criteria for method precision are met, the method will be proposed as a new Work Item to the European Committee for Standardisation. PMID:26212568
Schaffer, Michael; Cheng, Chen-Chih; Chao, Oscar; Hill, Virginia; Matsui, Paul
2016-03-01
An LC/MS/MS method to identify and quantitate in hair the minor metabolites of cocaine-meta-, para-, and ortho-hydroxy cocaine-was developed and validated. Analysis was performed on a triple quadrupole ABSciex API 3000 MS equipped with an atmospheric pressure ionization source via an IonSpray (ESI). For LC, a series 200 micro binary pump with a Perkin Elmer Model 200 autosampler was used. The limit of detection (LOD) and limit of quantification (LOQ) were 0.02 ng/10 mg hair, with linearity from 0.02 to 10 ng/10 mg hair. Concentrations of the para isomer in extensively washed hair samples were in the range of 1-2 % of the cocaine in the sample, while the concentrations of the ortho form were considerably less. The method was used to analyze large numbers of samples from two populations: workplace and criminal justice. In vitro experiments to determine if deodorants or peroxide-containing cosmetic treatments could result in the presence of these metabolites in hair showed that this does not occur with extensively washed hair. Presence of hydroxycocaines, when detected after aggressive washing of the hair samples, provides a valuable additional indicator of ingestion of cocaine rather than mere environmental exposure.
Szerkus, Oliwia; Struck-Lewicka, Wiktoria; Kordalewska, Marta; Bartosińska, Ewa; Bujak, Renata; Borsuk, Agnieszka; Bienert, Agnieszka; Bartkowska-Śniatkowska, Alicja; Warzybok, Justyna; Wiczling, Paweł; Nasal, Antoni; Kaliszan, Roman; Markuszewski, Michał Jan; Siluk, Danuta
2017-02-01
The purpose of this work was to develop and validate a rapid and robust LC-MS/MS method for the determination of dexmedetomidine (DEX) in plasma, suitable for analysis of a large number of samples. Systematic approach, Design of Experiments, was applied to optimize ESI source parameters and to evaluate method robustness, therefore, a rapid, stable and cost-effective assay was developed. The method was validated according to US FDA guidelines. LLOQ was determined at 5 pg/ml. The assay was linear over the examined concentration range (5-2500 pg/ml), Results: Experimental design approach was applied for optimization of ESI source parameters and evaluation of method robustness. The method was validated according to the US FDA guidelines. LLOQ was determined at 5 pg/ml. The assay was linear over the examined concentration range (R 2 > 0.98). The accuracies, intra- and interday precisions were less than 15%. The stability data confirmed reliable behavior of DEX under tested conditions. Application of Design of Experiments approach allowed for fast and efficient analytical method development and validation as well as for reduced usage of chemicals necessary for regular method optimization. The proposed technique was applied to determination of DEX pharmacokinetics in pediatric patients undergoing long-term sedation in the intensive care unit.
Determination of Acid Herbicides Using Modified QuEChERS with Fast Switching ESI(+)/ESI(-) LC-MS/MS.
Sack, Chris; Vonderbrink, John; Smoker, Michael; Smith, Robert E
2015-11-04
A method for the determination of 35 acid herbicides in food matrices was developed, validated, and implemented. It utilizes a modified QuEChERS extraction procedure coupled with quantitation by liquid chromatography tandem mass spectrometry (LC-MS/MS). The acid herbicides analyzed are all organic carboxylic acids, including the older chlorophenoxy acid herbicides such as 2,4-dichlorophenoxyacetic acid (2,4-D), dicamba, 4-chlorophenoxyacetic acid (4-CPA), quinclorac, and many of the newer imidazolinone herbicides such as imazethapyr and imazaquin. In the procedure, 10 mL of water is added to 5 g of sample and then extracted with 1% formic acid in acetonitrile for 1 min. The acetonitrile phase is salted out of the extract by adding sodium chloride and magnesium sulfate, followed by centrifugation. The acetonitrile is diluted 1:1 with water to enable quantitation by LC-MS/MS using fast switching between positive and negative electrospray ionization modes. The average recoveries for all the compounds except aminocyclopyrachlor were 95% with a precision of 8%. The method detection limits for all residues were less than 10 ng/g, and the correlation coefficients for the calibration curves was greater than 0.99 for all but two compounds tested. The method was used successfully for the quantitation of acid herbicides in the FDA's total diet study. The procedure proved to be accurate, precise, linear, sensitive, and rugged.
Mottier, Pascal; Khong, Seu-Ping; Gremaud, Eric; Richoz, Janique; Delatour, Thierry; Goldmann, Till; Guy, Philippe A
2005-03-04
A confirmatory method based on isotope dilution liquid chromatography-tandem mass spectrometry (LC-MS/MS) has been developed for the low-level determination of residues of four nitrofuran veterinary drugs in meat, e.g., furazolidone, furaltadone, nitrofurantoin, and nitrofurazone. The procedure entails an acid-catalysed release of protein-bound metabolites, followed by their in situ conversion into the 2-nitrobenzaldehyde (NBA) imine-type derivatives. Liquid-liquid extraction and clean-up on a polymeric solid phase extraction cartridge are then performed before LC-MS/MS analysis by positive electrospray ionisation (ESI) applying multiple reaction monitoring of three transition reactions for each compound. Reliable quantitation is obtained by using one deuterated analogue per analyte (d4-NBA derivative) as internal standard (IS). Validation of the method in chicken meat was conducted following the European Union (EU) criteria for the analysis of veterinary drug residues in foods. The decision limits (CCalpha) were 0.11-0.21 microg/kg, and the detection capabilities (CCbeta) 0.19-0.36 microg/kg, thus below the minimum required performance limit (MRPL) set at 1 microg/kg by the EU. The method is robust and suitable for routine quality control operations, and more than 200 sample injections were performed without excessive pollution of the mass spectrometer or loss of LC column performance.
Optimal energy-splitting method for an open-loop liquid crystal adaptive optics system.
Cao, Zhaoliang; Mu, Quanquan; Hu, Lifa; Liu, Yonggang; Peng, Zenghui; Yang, Qingyun; Meng, Haoran; Yao, Lishuang; Xuan, Li
2012-08-13
A waveband-splitting method is proposed for open-loop liquid crystal adaptive optics systems (LC AOSs). The proposed method extends the working waveband, splits energy flexibly, and improves detection capability. Simulated analysis is performed for a waveband in the range of 350 nm to 950 nm. The results show that the optimal energy split is 7:3 for the wavefront sensor (WFS) and for the imaging camera with the waveband split into 350 nm to 700 nm and 700 nm to 950 nm, respectively. A validation experiment is conducted by measuring the signal-to-noise ratio (SNR) of the WFS and the imaging camera. The results indicate that for the waveband-splitting method, the SNR of WFS is approximately equal to that of the imaging camera with a variation in the intensity. On the other hand, the SNR of the WFS is significantly different from that of the imaging camera for the polarized beam splitter energy splitting scheme. Therefore, the waveband-splitting method is more suitable for an open-loop LC AOS. An adaptive correction experiment is also performed on a 1.2-meter telescope. A star with a visual magnitude of 4.45 is observed and corrected and an angular resolution ability of 0.31″ is achieved. A double star with a combined visual magnitude of 4.3 is observed as well, and its two components are resolved after correction. The results indicate that the proposed method can significantly improve the detection capability of an open-loop LC AOS.
Boenzi, Sara; Deodato, Federica; Taurisano, Roberta; Martinelli, Diego; Verrigni, Daniela; Carrozzo, Rosalba; Bertini, Enrico; Pastore, Anna; Dionisi-Vici, Carlo; Johnson, David W
2014-11-01
Two oxysterols, cholestan-3β,5α,6β-triol (C-triol) and 7-ketocholesterol (7-KC), have been recently proposed as diagnostic markers of Niemann-Pick type C (NP-C) disease, representing a potential alternative diagnostic tool to the more invasive and time consuming filipin test in cultured fibroblasts. Usually, the oxysterols are detected and quantified by liquid chromatography-tandem mass spectrometry (LC-MS/MS) method using atmospheric pressure chemical ionization (APCI) or electro-spray-ionization (ESI) sources, after a variety of derivatization procedures to enhance sensitivity. We developed a sensitive LC-MS/MS method to quantify the oxysterols in plasma as dimethylaminobutyrate ester, suitable for ESI analysis. This method, with an easy liquid-phase extraction and a short derivatization procedure, has been validated to demonstrate specificity, linearity, recovery, lowest limit of quantification, accuracy and precision. The assay was linear over a concentration range of 0.5-200ng/mL for C-triol and 1.0-200ng/mL for 7-KC. Intra-day and inter-day coefficients of variation (CV%) were <15% for both metabolites. Receiver operating characteristic analysis estimates that the area under curve was 0.998 for C-triol, and 0.972 for 7-KC, implying a significant discriminatory power for the method in this patient population of both oxysterols. In summary, our method provides a simple, rapid and non-invasive diagnostic tool for the biochemical diagnosis of NP-C disease. Copyright © 2014 Elsevier B.V. All rights reserved.
Raizman, Joshua E; Taylor, Katherine; Parshuram, Christopher; Colantonio, David A
2017-05-01
Milrinone is a potent selective phosphodiesterase type III inhibitor which stimulates myocardial function and improves myocardial relaxation. Although therapeutic monitoring is crucial to maintain therapeutic outcome, little data is available. A proof-of-principle study has been initiated in our institution to evaluate the clinical impact of optimizing milrinone dosing through therapeutic drug monitoring (TDM) in children following cardiac surgery. We developed a robust LC-MS/MS method to quantify milrinone in serum from pediatric patients in real-time. A liquid-liquid extraction procedure was used to prepare samples for analysis prior to measurement by LC-MS/MS. Performance characteristics, such as linearity, limit of quantitation (LOQ) and precision, were assessed. Patient samples were acquired post-surgery and analyzed to determine the concentration-time profile of the drug as well as to track turn-around-times. Within day precision was <8.3% across 3 levels of QC. Between-day precision was <12%. The method was linear from 50 to 800μg/l; the lower limit of quantification was 22μg/l. Comparison with another LC-MS/MS method showed good agreement. Using this simplified method, turnaround times within 3-6h were achievable, and patient drug profiles demonstrated that some milrinone levels were either sub-therapeutic or in the toxic range, highlighting the importance for milrinone TDM. This simplified and quick method proved to be analytically robust and able to provide therapeutic monitoring of milrinone in real-time in patients post-cardiac surgery. Copyright © 2017. Published by Elsevier B.V.
Mahu, Ştefania Corina; Hăncianu, Monica; Agoroaei, Luminiţa; Grigoriu, Ioana Cezara; Strugaru, Anca Monica; Butnaru, Elena
2015-01-01
Hypertension is one of the most common causes of death, a complex and incompletely controlled disease for millions of patients. Metoprolol, bisoprolol, nebivolol and atenolol are selective beta-blockers frequently used in the management of arterial hypertension, alone or in fixed combination with other substances. This study presents the most used analytical methods for simultaneous determination in biological fluids of fixed combinations containing selective beta-blockers. Articles in Pub-Med, Science Direct and Wiley Journals databases published between years 2004-2014 were reviewed. Methods such as liquid chromatography--mass spectrometry--mass spectrometry (LC-MS/MS), high performance liquid chromatography (HPLC) or high performance liquid chromatography--mass spectrometry (HPLC-MS) were used for determination of fixed combination with beta-blockers in human plasma, rat plasma and human breast milk. LC-MS/MS method was used for simultaneous determination of fixed combinations of metoprolol with simvastatin, hydrochlorothiazide or ramipril, combinations of nebivolol and valsartan, or atenolol and amlodipine. Biological samples were processed by protein precipitation techniques or by liquid-liquid extraction. For the determination of fixed dose combinations of felodipine and metoprolol in rat plasma liquid chromatography--electrospray ionization--mass spectrometry (LC-ESI-MS/MS) was applied, using phenacetin as internal standard. HPLC-MS method was applied for the determination of bisoprolol and hydrochlorothiazide in human plasma. For the determination of atenolol and chlorthalidone from human breast milk and human plasma the HPLC method was used. The analytical methods were validated according to the specialized guidelines, and were applied to biological samples, thing that confirms the permanent concern of researchers in this field.
Zhang, Tong; Watson, David G
2015-05-07
The applications of metabolomics as a methodology for providing better treatment and understanding human disease continue to expand rapidly. In this review, covering the last two years, the focus is on liquid chromatography-mass spectrometry (LC-MS) profiling of metabolites in urine. In LC-MS based metabolomics there are still problems with regard to: chromatographic separation, peak picking and alignment, metabolite identification, metabolite coverage, instrument sensitivity and data interpretation and in the case of urine sample normalisation. Progress has been made with regard to all of these issues during the period of the review. Of particular interest are the increasing use of orthogonal chromatographic methods for optimal metabolite coverage and the increasing adoption of receiver operator characteristic (ROC) curves for biomarker validation.
Zhang, Meng-Qi; Jia, Jing-Ying; Lu, Chuan; Liu, Gang-Yi; Yu, Cheng-Yin; Gui, Yu-Zhou; Liu, Yun; Liu, Yan-Mei; Wang, Wei; Li, Shui-Jun; Yu, Chen
2010-06-01
A simple, reliable and sensitive liquid chromatography-isotope dilution mass spectrometry (LC-ID/MS) was developed and validated for quantification of olanzapine in human plasma. Plasma samples (50 microL) were extracted with tert-butyl methyl ether and isotope-labeled internal standard (olanzapine-D3) was used. The chromatographic separation was performed on XBridge Shield RP 18 (100 mm x 2.1 mm, 3.5 microm, Waters). An isocratic program was used at a flow rate of 0.4 m x min(-1) with mobile phase consisting of acetonitrile and ammonium buffer (pH 8). The protonated ions of analytes were detected in positive ionization by multiple reactions monitoring (MRM) mode. The plasma method, with a lower limit of quantification (LLOQ) of 0.1 ng x mL(-1), demonstrated good linearity over a range of 0.1 - 30 ng x mL(-1) of olanzapine. Specificity, linearity, accuracy, precision, recovery, matrix effect and stability were evaluated during method validation. The validated method was successfully applied to analyzing human plasma samples in bioavailability study.
Ozkan Cansel, Kose; Ozgur, Esim; Sevinc, Kurbanoglu; Ayhan, Savaser; Ozkan, Sibel A; Yalcin, Ozkan
2016-01-01
Pharmaceutical preparations of ezetimibe and atorvastatin are generally used to regulate the lipid level in blood. It decreases the secondary events for patients with high cholesterol and clinical cardiovascular disease such as non-fatal or fatal heart attack. There is no any pharmacopoeia method available for the dissolution testing recommended by the FDA. Development of dissolution tests method is very critical parameter especially for the pharmaceutical preparations that contain Class II drugs (slightly soluble, good permeable). In the proposed method, the effects of pH and surfactant on the dissolution of poorly water soluble combined drug therapy with a different pKa values in an in vitro environment is investigated. The content of our study was designed to answer these open-ended questions. The optimized test conditions achieved under sink conditions with USP apparatus 2 at a paddle rotation speed of 75 rpm and 900 ml in 0.01 M Acetate buffer (pH= 6.8) containing 0.45% SDS as a dissolution medium. Quantification of dissolution samples were analyzed with a new fully validated RP-LC method with UV detection at 242 nm.
Li, Wei; Herrman, Timothy J; Dai, Susie Y
2010-01-01
A simple, fast, and robust method was developed for the determination of fumonisin B1 (FB1), fumonisin B2 (FB2), and fumonisin B3 (FB3) in corn-based human food and animal feed (cornmeal). The method involves a single extraction step followed by centrifugation and filtration before analysis by ultra-performance liquid chromatographylelectrospray ionization (UPLC/ESI)-MS/MS. The LC/MS/MS method developed here represents the fastest and simplest procedure (<30 min) among both conventional HPLC methods and other LC/MS methods using SPE cleanup. The potential for high throughput analysis makes the method particularly beneficial for regulatory agencies and analytical laboratories with a high sample volume. A single-laboratory validation was conducted by testing three different spiking levels (200, 500, and 1000 ng/g for FB1 and FB2; 100, 250, and 500 ng/g for FB3) for accuracy and precision. Recoveries of FB1 ranged from 93 to 98% with RSD values of 3-8%. Recoveries of FB2 ranged from 104 to 108%, with RSD values of 2-6%. Recoveries of FB3 ranged from 94 to 108%, with RSD values of 2-5%.
Hess, Cornelius; Ritke, Natalie; Broecker, Sebastian; Madea, Burkhard; Musshoff, Frank
2013-05-01
The antihelminthic drug Levamisole can enhance cocaine effects by conversion into the amphetamine-like drug aminorex. We describe an LC-MS method for the determination of levamisole and its metabolite aminorex in human urine. Selectivity is given, calibration curves were linear within the calibration range 2.5-250 ng/mL; limits of the method were LoD 0.51 ng/mL, LoQ 1.02 ng/mL for levamisole and LoD 0.65 ng/mL, LoQ 0.76 ng/mL for aminorex. Precision data was in accordance with the guidelines (intraday precision for aminorex ranged between 5.75 and 11.0 % for levamisole between 8.36 and 10.9 %; interday precision for levamisole 10.9-16.9 % and for aminorex 7.64-12.7 %; accuracy data for levamisole -1.96 to -14.3 % and for aminorex-11.9 to-18.5 %). The validated method was successfully applied to study the urinary excretion of levamisole after the administration of 100 mg of levamisole orally. Levamisole and aminorex could be detected in post-administration urine samples. Levamisole could be detected up to 39 h after ingestion, while aminorex was detectable up to 54 h. Maximum aminorex concentrations were 45 ng/mL urine. Further metabolites of levamisole after oral ingestion by means of liquid chromatography hybrid quadrupole time-of-flight high-resolution mass spectrometry (LC-QTOF-HRMS) were identified. Only 0.5 % of the ingested drug was quantified as unchanged levamisole in urine. Besides aminorex, five isomers of aminorex and 4 hydroxy-metabolites of aminorex or its isomers were found. Furthermore, levamisole is also hydroxylated and eliminated free or conjugated with sulfate or glucuronide into urine.
Absolute quantification of histone PTM marks by MRM-based LC-MS/MS.
Gao, Jun; Liao, Rijing; Yu, Yanyan; Zhai, Huili; Wang, Yingqi; Sack, Ragna; Peters, Antoine H F M; Chen, Jiajia; Wu, Haiping; Huang, Zheng; Hu, Min; Qi, Wei; Lu, Chris; Atadja, Peter; Oyang, Counde; Li, En; Yi, Wei; Zhou, Shaolian
2014-10-07
The N-terminal tails of core histones harbor the sites of numerous post-translational modifications (PTMs) with important roles in the regulation of chromatin structure and function. Profiling histone PTM marks provides data that help understand the epigenetics events in cells and their connections with cancer and other diseases. Our previous study demonstrated that specific derivatization of histone peptides by NHS propionate significantly improved their chromatographic performance on reversed phase columns for LC/MS analysis. As a step forward, we recently developed a multiple reaction monitoring (MRM) based LC-MS/MS method to analyze 42 targeted histone peptides. By using stable isotopic labeled peptides as internal standards that are spiked into the reconstituted solutions, this method allows to measure absolute concentration of the tryptic peptides of H3 histone proteins extracted from cancer cell lines. The method was thoroughly validated for the accuracy and reproducibility through analyzing recombinant histone proteins and cellular samples. The linear dynamic range of the MRM assays was achieved in 3 orders of magnitude from 1 nM to 1 μM for all targeted peptides. Excellent intrabatch and interbatch reproducibility (<15% CV) was obtained. This method has been used to study translocated NSD2 (a histone lysine methyltransferase that catalyzes the histone lysine 36 methylation) function with its overexpression in KMS11 multiple myeloma cells. From the results we have successfully quantitated both individual and combinatorial histone marks in parental and NSD2 selective knockout KMS11 cells.
Liu, Jingjing; Li, Qing; Yin, Yidi; Liu, Ran; Xu, Huarong; Bi, Kaishun
2014-01-01
A fast, sensitive, and efficient ultra-fast LC-ESI-MS/MS method was developed for the simultaneous quantitation of six highly toxic Aconitum alkaloids, that is, aconitine, mesaconitine, hypaconitine, benzoylaconine, benzoylmesaconine, and benzoylhypaconine, in rat plasma after oral administration of crude ethanol extracts from Aconiti kusnezoffii radix by ultrasonic extraction, reflux extraction for 1 h, and reflux extraction for 3 h, respectively. The separation of six Aconitum alkaloids and aminopyrine (internal standard) was performed on an InertSustain® C18 column, and the quantification of the analytes was performed on a 4000Q ultra-fast LC-MS/MS system with turbo ion spray source in the positive ion and multiple-reaction monitoring mode. Absolute recoveries ranged within 65.06-85.1% for plasma samples. The intra- and interday precision and accuracy of analytes were satisfactory. The methods were validated with sensitivity reaching the lower LOQ for aconitine, mesaconitine, hypaconitine, benzoylaconine, benzoylmesaconine, and benzoylhypaconine, which were 0.025, 0.025, 0.050, 0.025, 0.025, and 0.100 ng/mL, respectively. The method was successfully applied to a pharmacokinetic study of six Aconitum alkaloids in rat plasma after oral administration of crude ethanol extracts from the raw root of Aconitum kusnezoffii Reichb. by three different extraction processes. © 2013 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.
Zhang, Xing; Wang, Xiaoming; Vernikovskaya, Daria I; Fokina, Valentina M; Nanovskaya, Tatiana N; Hankins, Gary D V; Ahmed, Mahmoud S
2015-04-01
This report describes the development and validation of an LC-MS/MS method for the quantitative determination of glyburide (GLB), its five metabolites (M1, M2a, M2b, M3 and M4) and metformin (MET) in plasma and urine of pregnant patients under treatment with a combination of the two medications. The extraction recovery of the analytes from plasma samples was 87-99%, and that from urine samples was 85-95%. The differences in retention times among the analytes and the wide range of the concentrations of the medications and their metabolites in plasma and urine patient samples required the development of three LC methods. The lower limit of quantitation (LLOQ) of the analytes in plasma samples was as follows: GLB, 1.02 ng/mL; its five metabolites, 0.100-0.113 ng/mL; and MET, 4.95 ng/mL. The LLOQ in urine samples was 0.0594 ng/mL for GLB, 0.984-1.02 ng/mL for its five metabolites and 30.0 µg/mL for MET. The relative deviation of this method was <14% for intra-day and inter-day assays in plasma and urine samples, and the accuracy was 86-114% in plasma, and 94-105% in urine. The method described in this report was successfully utilized for determining the concentrations of the two medications in patient plasma and urine. Copyright © 2014 John Wiley & Sons, Ltd.
Zhang, Xing; Wang, Xiaoming; Vernikovskaya, Daria I.; Fokina, Valentina M.; Nanovskaya, Tatiana N.; Hankins, Gary D.V.; Ahmed, Mahmoud S.
2014-01-01
This report describes the development and validation of an LC-MS/MS method for the quantitative determination of glyburide (GLB), its five metabolites (M1, M2a, M2b, M3, and M4) and metformin (MET) in plasma and urine of pregnant patients under treatment with a combination of the two medications. The extraction recovery of the analytes from plasma samples ranged between 87% and 99%, and 85%–95% for urine samples. The differences in retention times among the analytes, and the wide range of the concentrations of the medications and their metabolites in plasma and urine patient samples required the development of three LC methods. The lower limit of quantitation (LLOQ) of the analytes in plasma samples was as follows: GLB, 1.02 ng/mL; its five metabolites, 0.100–0.113 ng/mL and 4.95 ng/mL for MET. LLOQ in urine samples was 0.0594 ng/mL for GLB, 0.984–1.02 ng/mL for its five metabolites and 30.0 μg/mL for MET. The relative deviation of this method was < 14% for intra-day and inter-day assays in plasma and urine samples, and the accuracy ranged between 86% and 114% in plasma, and 94% to 105% in urine. The method described in this report was successfully utilized for determining the concentrations of the two medications in patient plasma and urine. PMID:25164921
Dalmora, Sergio Luiz; Nogueira, Daniele Rubert; D'Avila, Felipe Bianchini; Souto, Ricardo Bizogne; Leal, Diogo Paim
2011-01-01
A stability-indicating capillary zone electrophoresis (CZE) method was validated for the analysis of entecavir in pharmaceutical formulations, using nimesulide as an internal standard. A fused-silica capillary (50 µm i.d.; effective length, 40 cm) was used while being maintained at 25°C; the applied voltage was 25 kV. A background electrolyte solution consisted of a 20 mM sodium tetraborate solution at pH 10. Injections were performed using a pressure mode at 50 mbar for 5 s, with detection at 216 nm. The specificity and stability-indicating capability were proven through forced degradation studies, evaluating also the in vitro cytotoxicity test of the degraded products. The method was linear over the concentration range of 1-200 µg mL(-1) (r(2) = 0.9999), and was applied for the analysis of entecavir in tablet dosage forms. The results were correlated to those of validated conventional and fast LC methods, showing non-significant differences (p > 0.05).
Ring, P R; Bostick, J M
2000-04-01
A sensitive and selective high-performance liquid chromatography (HPLC) method was developed for the determination of zolpidem in human plasma. Zolpidem and the internal standard (trazodone) were extracted from human plasma that had been made basic. The basic sample was loaded onto a conditioned Bond Elut C18 cartridge, rinsed with water and eluted with methanol. Forty microliters were then injected onto the LC system. Separation was achieved on a C18 column (150 x 4.6 mm, 5 microm) with a mobile phase composed of acetonitrile:50 mM potassium phosphate monobasic at pH 6.0 (4:6, v/v). Detection was by fluorescence, with excitation at 254 nm and emission at 400 nm. The retention times of zolpidem and internal standard were approximately 4.7 and 5.3 min, respectively. The LC run time was 8 min. The assay was linear in concentration range 1-400 ng/ml for zolpidem in human plasma. The analysis of quality control samples for zolpidem (3, 30, and 300 ng/ml) demonstrated excellent precision with relative standard deviations (RSD) of 3.7, 4.6, and 3.0%, respectively (n = 18). The method was accurate with all intraday (n = 6) and overall (n = 18) mean concentrations within 5.8% from nominal at all quality control sample concentrations. This method was also performed using a Gilson Aspec XL automated sample processor and autoinjector. The samples were manually fortified with internal standard and made basic. The aspec then performed the solid phase extraction and made injections of the samples onto the LC system. Using the automated procedure for analysis, quality control samples for zolpidem (3, 30, and 300 ng/ml) demonstrated acceptable precision with RSD values of 9.0, 4.9, and 5.1%, respectively (n = 12). The method was accurate with all intracurve (n = 4) and overall (n = 12) mean values being less than 10.8% from nominal at all quality control sample concentrations.
Seserko, Lauren A; Emory, Joshua F; Hendrix, Craig W; Marzinke, Mark A
2013-11-01
Dapivirine is a non-nucleoside reverse transcriptase inhibitor designed to prevent HIV-1 viral replication and subsequent propagation. A sensitive method is required to quantify plasma concentrations to assess drug efficacy. Dapivirine-spiked plasma was combined with acetonitrile containing deuterated IS and was processed for analysis. The method has an analytical measuring range from 20 to 10,000 pg/ml. For the LLOQ, low, mid and high QCs, intra- and inter-assay precision (%CV) ranged from 5.58 to 13.89% and 5.23 to 13.36%, respectively, and intra- and inter-day accuracy (% deviation) ranged from -5.61 to 0.75% and -4.30 to 6.24%, respectively. A robust and sensitive LC-MS/MS assay for the high-throughput quantification of the antiretroviral drug dapivirine in human plasma was developed and validated following bioanalytical validation guidelines. The assay meets criteria for the analysis of samples from large research trials.
Downes, Katherine; Terry, Leon A
2010-06-30
Onion soluble non-structural carbohydrates consist of fructose, glucose and sucrose plus fructooligosaccharides (FOS) with degrees of polymerisation (DP) in the range of 3-19. In onion, sugars and FOS are typically separated using liquid chromatography (LC) with acetonitrile (ACN) as a mobile phase. In recent times, however, the production of ACN has diminished due, in part, to the current worldwide economic recession. A study was therefore undertaken, to find an alternative LC method to quantify sugars and FOS from onion without the need for ACN. Two mobile phases were compared; the first taken from a paper by Vågen and Slimestad (2008) using ACN mobile phase, the second, a newly reported method using ethanol (EtOH). The EtOH mobile phase eluted similar concentrations of all FOS compared to the ACN mobile phase. In addition, limit of detection, limit of quantification and relative standard deviation values were sufficiently and consistently lower for all FOS using the EtOH mobile phase. The drawback of the EtOH mobile phase was mainly the inability to separate all individual sugar peaks, yet FOS could be successfully separated. However, using the same onion extract, a previously established LC method based on an isocratic water mobile phase could be used in a second run to separate sugars. Although the ACN mobile phase method is more convenient, in the current economic climate a method based on inexpensive and plentiful ethanol is a valid alternative and could potentially be applied to other fresh produce types. In addition to the mobile phase solvent, the effect of extraction solvents on sugar and FOS concentration was also investigated. EtOH is still widely used to extract sugars from onion although previous literature has concluded that MeOH is a superior solvent. For this reason, an EtOH-based extraction method was compared with a MeOH-based method to extract both sugars and FOS. The MeOH-based extraction method was more efficacious at extracting sugars and FOS from onion flesh, eluting significantly higher concentrations of glucose, kestose, nystose and DP5-DP8. Copyright 2010 Elsevier B.V. All rights reserved.
Khaksari, Maryam; Mazzoleni, Lynn R; Ruan, Chunhai; Kennedy, Robert T; Minerick, Adrienne R
2017-04-01
Two separate liquid chromatography (LC)-mass spectrometry (MS) methods were developed for determination and quantification of water-soluble and fat-soluble vitamins in human tear and blood serum samples. The water-soluble vitamin method was originally developed to detect vitamins B 1 , B 2 , B 3 (nicotinamide), B 5 , B 6 (pyridoxine), B 7 , B 9 and B 12 while the fat-soluble vitamin method detected vitamins A, D 3 , 25(OH)D 3, E and K 1 . These methods were then validated with tear and blood serum samples. In this data in brief article, we provide details on the two LC-MS methods development, methods sensitivity, as well as precision and accuracy for determination of vitamins in human tears and blood serum. These methods were then used to determine the vitamin concentrations in infant and parent samples under a clinical study which were reported in "Determination of Water-Soluble and Fat-Soluble Vitamins in Tears and Blood Serum of Infants and Parents by Liquid Chromatography/Mass Spectrometry DOI:10.1016/j.exer.2016.12.007 [1]". This article provides more details on comparison of vitamin concentrations in the samples with the ranges reported in the literature along with the medically accepted normal ranges. The details on concentrations below the limits of detection (LOD) and limits of quantification (LOQ) are also discussed. Vitamin concentrations were also compared and cross-correlated with clinical data and nutritional information. Significant differences and strongly correlated data were reported in [1]. This article provides comprehensive details on the data with slight differences or slight correlations.
Pruvost, A; Becher, F; Bardouille, P; Guerrero, C; Creminon, C; Delfraissy, J F; Goujard, C; Grassi, J; Benech, H
2001-01-01
The objective was to develop and validate a routine assay for active intracellular anabolites of stavudine (d4T), a nucleoside reverse transcriptase inhibitor in human PBMC, applicable to pharmacokinetic studies and treatment monitoring. This was achieved using liquid chromatography coupled to tandem mass spectrometry (LC/MS/MS), which theoretically allies optimum sensitivity, specificity and high sample throughput. After cellular lysis in a Tris/methanol buffer, the extract spiked with 2[H(8)]-ATP (internal standard) is directly injected into the LC/MS/MS system. Phosphorylated metabolites of d4T as well as deoxythymidine-triphosphate, the competitor on the reverse transcriptase, are separated from d4T on a reverse-phase microbore column with ion pairing. The detection is performed in the multiple reaction monitoring (MRM) mode after drug ionisation in negative mode electrospray. The limit of quantitation for d4T-TP was 138 fmol per 7 mL blood (9.8 fmol per 10(6) cells) and CV% for repeatability and intermediate precision were lower than 15%. Stability of compounds was checked before and during the process of isolation of PBMC. Cellular samples from several d4T-treated patients were successfully analysed using this method and d4T-triphosphate and deoxythymidine triphosphate were recovered. In conclusion, we have developed and validated a routine LC/MS/MS method that allows the simultaneous determination of mono-, di- and triphosphorylated anabolites of d4T in PBMC as well as the natural corresponding triphosphate in one analysis. For the first time, the chain terminator ratio (d4T-TP/dT-TP) could be directly measured. This method can be used simply and routinely on more than 35 samples per day. Extension to other nucleoside analogues is under development. Copyright 2001 John Wiley & Sons, Ltd.
Misra, A; Kushwaha, H N; Gautam, N; Singh, B; Verma, P C; Pratap, R; Singh, S K
2014-08-01
A sensitive and selective LC-MS/MS method has been developed and validated for CDRI antidiabetic candidate S007-1261 in rat plasma using 16-dehydropregnenolone as an internal standard. The API 4000 triple quadrupole LC-MS/MS system was operated under multiple reaction monitoring mode using electrospray ionization technique in positive mode. The sample processing method involves 2-step liquid-liquid extraction using n-hexane as an extracting solvent. The analyte was chromatographed on RP 18, waters column (3.5 µm, 2.1 mm i.d. × 30 mm) with guard using acetonitrile and ammonium acetate buffer (pH 5.0, 10 mM) in 90:10 (v/v) composition at a flow rate of 0.40 mL min(-1). The chromatographic run time was 5.30 min. Calibration curve shows linearity over concentration range 1.56-200 ng mL(-1). The lower limit of detection was 0.39 ng mL(-1) and lower limit of quantitation was 1.56 ng mL(-1). The inter- and intra-day accuracy and precision were found to be within the assay variability limits as per US FDA guidelines. The absolute recovery of S007-1261 was found to be >90%. S007-1261 does not show any stability problems as it was stable at room temperature for 8 h. S007-1261 was also stable up to 3 freeze-thaw cycles and can be stored up to 30 days at -60 °C. The assay was successfully applied to both oral (40 mg kg(-1)) and intravenous (10 mg kg(-1)) pharmacokinetic studies in male Sprague-Dawley rats. The oral bioavailability of S007-1261 was found to be 33.61%. © Georg Thieme Verlag KG Stuttgart · New York.
Balaji, Narayanan; Sulochana, Suresh P; Saini, Neeraj Kumar; A, Siva Kumar; Mullangi, Ramesh
2018-05-01
A simple, selective and reliable LC-MS/MS method was validated for simultaneous quantitation of darolutamide diastereomers in 50 μL mouse plasma using warfarin as an internal standard (IS) as per regulatory guidelines. Plasma samples were extracted by liquid-liquid extraction and the chromatographic separation was achieved on a Chiralpak IA column with an isocratic mobile phase 5 mm ammonium acetate-absolute alcohol (20:80, v/v) at a flow rate of 1.0 mL/min. Detection and quantitation was done in multiple reaction monitoring mode following the transitions m/z 397 → 202 and 307 → 250 for darolutamide diastereomers and the IS, respectively, in the negative ionization mode. The linearity range was 100-2400 ng/mL for each diastereomer. The intra- and inter-day precisions were in the ranges of 1.78-4.20 and 4.34-14.6, and 3.63-4.74 and 4.78-5.15 for diastereomer-1 and diastereomer-2, respectively. Both diastereomers were found to be stable under different stability conditions. The validated method was applied to a pharmacokinetic study in mice. Following oral administration of darolutamide at 10 mg/kg, maximum concentration in plasma was 4189 and 726 ng/mL for diastereomer-1 and diastereomer-2, respectively. The terminal half-life was found to be ~0.50 h for both the diastereomers. The AUC (0-t) was found to be 18,961 ng*h/mL for diastereomer-1 and 1340 ng*h/mL diastereomer-2. Copyright © 2018 John Wiley & Sons, Ltd.
Chandra, A; Rana, J; Li, Y
2001-08-01
A method has been established and validated for identification and quantification of individual, as well as total, anthocyanins by HPLC and LC/ES-MS in botanical raw materials used in the herbal supplement industry. The anthocyanins were separated and identified on the basis of their respective M(+) (cation) using LC/ES-MS. Separated anthocyanins were individually calculated against one commercially available anthocyanin external standard (cyanidin-3-glucoside chloride) and expressed as its equivalents. Amounts of each anthocyanin calculated as external standard equivalent were then multiplied by a molecular-weight correction factor to afford their specific quantities. Experimental procedures and use of a molecular-weight correction factors are substantiated and validated using Balaton tart cherry and elderberry as templates. Cyanidin-3-glucoside chloride has been widely used in the botanical industry to calculate total anthocyanins. In our studies on tart cherry and elderberry, its use as external standard followed by use of molecular-weight correction factors should provide relatively accurate results for total anthocyanins, because of the presence of cyanidin as their major anthocyanidin backbone. The method proposed here is simple and has a direct sample preparation procedure without any solid-phase extraction. It enables selection and use of commercially available anthocyanins as external standards for quantification of specific anthocyanins in the sample matrix irrespective of their commercial availability as analytical standards. It can be used as a template and applied for similar quantification in several anthocyanin-containing raw materials for routine quality control procedures, thus providing consistency in analytical testing of botanical raw materials used for manufacturing efficacious and true-to-the-label nutritional supplements.
Kuze, Yoji; Kogame, Akifumi; Jinno, Fumihiro; Kondo, Takahiro; Asahi, Satoru
2015-09-15
Azilsartan medoxomil potassium salt (TAK-491) is an orally administered angiotensin II type 1 receptor blocker for the treatment of hypertension and is an ester-based prodrug that is rapidly hydrolyzed to the pharmacologically active moiety, azilsartan (TAK-536), during absorption. TAK-536 is biotransformed to the 2 metabolites M-I by decarboxylation and M-II by dealkylation. In this study, we developed and validated a LC/MS/MS method which can simultaneously determine 4 analytes, TAK-491, TAK-536, M-I and M-II. The bioanalytical method can be outlined as follows: two structural analogues are used as the internal standards. The analytes and the IS are extracted from human plasma using solid phase extraction. After evaporating, the residue is reconstituted and injected into a LC/MS/MS system with an ESI probe and analyzed in the positive ion mode. Separation is performed through a conventional reversed-phase column with a mobile phase of water/acetonitrile/acetic acid (40:60:0.05, v/v/v) mixture at a flow rate of 0.2mL/min. The total run time is 8.5min. The calibration range is 1-2500ng/mL in human plasma for all the analytes. Instability issues of the prodrug, TAK-491, were overcome and all the validation results met the acceptance criteria in accordance with the regulatory guideline/guidance. As a result of the clinical study, the human PK profiles of TAK-536, M-I and M-II were successfully obtained and also it was confirmed that TAK-491 was below the LLOQ (1ng/mL) in the human plasma samples. Copyright © 2015 Elsevier B.V. All rights reserved.
Choi1, Yong Seok; Lee, Kelvin H.
2016-01-01
Alzheimer's disease (AD) is the most common type of dementia, but early and accurate diagnosis remains challenging. Previously, a panel of cerebrospinal fluid (CSF) biomarker candidates distinguishing AD and non-AD CSF accurately (> 90%) was reported. Furthermore, a multiple reaction monitoring (MRM) assay based on nano liquid chromatography tandem mass spectrometry (nLC-MS/MS) was developed to help validate putative AD CSF biomarker candidates including proteins from the panel. Despite the good performance of the MRM assay, wide acceptance may be challenging because of limited availability of nLC-MS/MS systems laboratories. Thus, here, a new MRM assay based on conventional LC-MS/MS is presented. This method monitors 16 peptides representing 16 (of 23) biomarker candidates that belonged to the previous AD CSF panel. A 30-times more concentrated sample than the sample used for the previous study was loaded onto a high capacity trap column, and all 16 MRM transitions showed good linearity (average R2 = 0.966), intra-day reproducibility (average coefficient of variance (CV) = 4.78%), and inter-day reproducibility (average CV = 9.85%). The present method has several advantages such as a shorter analysis time, no possibility of target variability, and no need for an internal standard. PMID:26404792
Pérez Fernández, Virginia; Ventura, Salvatore; Tomai, Pierpaolo; Curini, Roberta; Gentili, Alessandra
2017-03-01
This paper describes an analytical approach, based on LC-diode array detector-MS/MS (LC-DAD-MS/MS), for characterizing the fat-soluble micronutrient fraction in rainbow trout (Oncorhynchus mykiss). Two different procedures were applied to isolate the analytes from liver and muscle tissue: overnight cold saponification to hydrolyze bound forms and to simplify the analysis; matrix solid-phase dispersion to avoid artifacts and to maintain unaltered the naturally occurring forms. Analytes were separated on a C 30 analytical column by using a nonaqueous reversed mobile phase compatible with the atmospheric pressure chemical ionization. Compared to other works, the most relevant advantage of the here illustrated method is the large amount of information obtained with few analytical steps: nine fat-soluble vitamins (3,4-dehydroretinol, retinol, cholecalciferol, ergocalciferol, α-tocopherol, γ-tocopherol, δ-tocopherol, phylloquinone, and menaquinone-4) and eight carotenoids (all-trans-lutein, all-trans-astaxanthin, all-trans-zeaxanthin, all-trans-β-cryptoxanthin, all-trans-canthaxanthin, all-trans-ζ-carotene, all-trans-β-carotene, and all-trans-γ-carotene) were quantified after the method validation, while other untargeted carotenoids were tentatively identified by exploiting the identification power of the LC-DAD-MS/MS hyphenation. © 2016 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.
Chen, Xun; Stout, Steven; Mueller, Uwe; Boykow, George; Visconti, Richard; Siliphaivanh, Phieng; Spencer, Kerrie; Presland, Jeremy; Kavana, Michael; Basso, Andrea D; McLaren, David G; Myers, Robert W
2017-08-01
We have developed and validated label-free, liquid chromatography-mass spectrometry (LC-MS)-based equilibrium direct and competition binding assays to quantitate small-molecule antagonist binding to recombinant human and mouse BLT1 receptors expressed in HEK 293 cell membranes. Procedurally, these binding assays involve (1) equilibration of the BLT1 receptor and probe ligand, with or without a competitor; (2) vacuum filtration through cationic glass fiber filters to separate receptor-bound from free probe ligand; and (3) LC-MS analysis in selected reaction monitoring mode for bound probe ligand quantitation. Two novel, optimized probe ligands, compounds 1 and 2, were identified by screening 20 unlabeled BLT1 antagonists for direct binding. Saturation direct binding studies confirmed the high affinity, and dissociation studies established the rapid binding kinetics of probe ligands 1 and 2. Competition binding assays were established using both probe ligands, and the affinities of structurally diverse BLT1 antagonists were measured. Both binding assay formats can be executed with high specificity and sensitivity and moderate throughput (96-well plate format) using these approaches. This highly versatile, label-free method for studying ligand binding to membrane-associated receptors should find broad application as an alternative to traditional methods using labeled ligands.
Choi, Yong Seok; Lee, Kelvin H
2016-03-01
Alzheimer's disease (AD) is the most common type of dementia, but early and accurate diagnosis remains challenging. Previously, a panel of cerebrospinal fluid (CSF) biomarker candidates distinguishing AD and non-AD CSF accurately (>90 %) was reported. Furthermore, a multiple reaction monitoring (MRM) assay based on nano liquid chromatography tandem mass spectrometry (nLC-MS/MS) was developed to help validate putative AD CSF biomarker candidates including proteins from the panel. Despite the good performance of the MRM assay, wide acceptance may be challenging because of limited availability of nLC-MS/MS systems in laboratories. Thus, here, a new MRM assay based on conventional LC-MS/MS is presented. This method monitors 16 peptides representing 16 (of 23) biomarker candidates that belonged to the previous AD CSF panel. A 30-times more concentrated sample than the sample used for the previous study was loaded onto a high capacity trap column, and all 16 MRM transitions showed good linearity (average R(2) = 0.966), intra-day reproducibility (average coefficient of variance (CV) = 4.78 %), and inter-day reproducibility (average CV = 9.85 %). The present method has several advantages such as a shorter analysis time, no possibility of target variability, and no need for an internal standard.
Dolder, Patrick C; Liechti, Matthias E; Rentsch, Katharina M
2015-02-01
Lysergic acid diethylamide (LSD) is a widely used recreational drug. The aim of the present study is to develop a quantitative turboflow LC-MS/MS method that can be used for rapid quantification of LSD and its main metabolite 2-oxo-3-hydroxy LSD (O-H-LSD) in serum and urine in emergency toxicological cases without time-consuming extraction steps. The method was developed on an ion-trap LC-MS/MS instrument coupled to a turbulent-flow extraction system. The validation data showed no significant matrix effects and no ion suppression has been observed in serum and urine. Mean intraday accuracy and precision for LSD were 101 and 6.84%, in urine samples and 97.40 and 5.89% in serum, respectively. For O-H-LSD, the respective values were 97.50 and 4.99% in urine and 107 and 4.70% in serum. Mean interday accuracy and precision for LSD were 100 and 8.26% in urine and 101 and 6.56% in serum, respectively. For O-H-LSD, the respective values were 101 and 8.11% in urine and 99.8 and 8.35% in serum, respectively. The lower limit of quantification for LSD was determined to be 0.1 ng/ml. LSD concentrations in serum were expected to be up to 8 ng/ml. 2-Oxo-3-hydroxy LSD concentrations in urine up to 250 ng/ml. The new method was accurate and precise in the range of expected serum and urine concentrations in patients with a suspected LSD intoxication. Until now, the method has been applied in five cases with suspected LSD intoxication where the intake of the drug has been verified four times with LSD concentrations in serum in the range of 1.80-14.70 ng/ml and once with a LSD concentration of 1.25 ng/ml in urine. In serum of two patients, the O-H-LSD concentration was determined to be 0.99 and 0.45 ng/ml. In the urine of a third patient, the O-H-LSD concentration was 9.70 ng/ml.
Chen, Hui; Wang, Xu; Chopra, Shruti; Adams, Erwin; Van Schepdael, Ann
2014-03-01
A new method for monitoring the enzyme inhibition of Abl1 tyrosine kinase by liquid chromatography-indirect pulsed electrochemical detection (LC-InPED) was developed. In this method, adsorption of a peptide analyte at the noble metal electrode suppresses the oxidation of polyols under alkaline condition to elicit an indirect response resulting in a negative peak of the target peptide. Among the reagents tested, D-gluconic acid sodium salt gave the best overall signal to noise (S/N) values for the indirect detection of p-Abltide, the product of Abl1 enzymatic reaction. 50 μM D-gluconic acid sodium salt dissolved in a mixture of 78% water-22% acetonitrile-0.03% trifluoroacetic acid (TFA) was used as the mobile phase. Chromatographic separation was achieved on an Alltima C18 (I.D. 5 μm; 250 mm × 4.6 mm) column with the mobile phase flow rate of 0.5 ml/min. 0.5M sodium hydroxide was added post-column to maintain alkaline conditions in the PED cell. The limit of quantification (LOQ) was 0.2 μM for p-Abltide, which was about 50-fold lower than direct PED analysis. The residual plot of the linear calibration curve indicated a good fit with a linear model within the investigated concentration range of p-Abltide. Intra- and inter-day precision was not more than 6.5% and accuracy was from -5.75% to +1.54%. The validated LC-InPED method was successfully applied for monitoring of p-Abltide in Abl1 enzyme reaction and the inhibition study of Abl1. The determined IC50 values of model inhibitors, imatinib, nilotinib and dasatinib, were 601.4 nM (R(2)=0.99), 32.3 nM (R(2)=0.99) and 1.3 nM (R(2)=0.98), respectively. These results were consistent with literature data. To the best of our knowledge this is the first time a LC-InPED method has been used to monitor an enzyme reaction. Copyright © 2013 Elsevier B.V. All rights reserved.
Dispas, Amandine; Desfontaine, Vincent; Andri, Bertyl; Lebrun, Pierre; Kotoni, Dorina; Clarke, Adrian; Guillarme, Davy; Hubert, Philippe
2017-02-05
In the last years, supercritical fluid chromatography has largely been acknowledged as a singular and performing technique in the field of separation sciences. Recent studies highlighted the interest of SFC for the quality control of pharmaceuticals, especially in the case of the determination of the active pharmaceutical ingredient (API). Nevertheless, quality control requires also the determination of impurities. The objectives of the present work were to (i) demonstrate the interest of SFC as a reference technique for the determination of impurities in salbutamol sulfate API and (ii) to propose an alternative to a reference HPLC method from the European Pharmacopeia (EP) involving ion-pairing reagent. Firstly, a screening was carried out to select the most adequate and selective stationary phase. Secondly, in the context of robust optimization strategy, the method was developed using design space methodology. The separation of salbutamol sulfate and related impurities was achieved in 7min, which is seven times faster than the LC-UV method proposed by European Pharmacopeia (total run time of 50min). Finally, full validation using accuracy profile approach was successfully achieved for the determination of impurities B, D, F and G in salbutamol sulfate raw material. The validated dosing range covered 50 to 150% of the targeted concentration (corresponding to 0.3% concentration level), LODs close to 0.5μg/mL were estimated. The SFC method proposed in this study could be presented as a suitable fast alternative to EP LC method for the quantitative determination of salbutamol impurities. Copyright © 2016 Elsevier B.V. All rights reserved.
Wabuyele, Simuli L; Wald, David; Xu, Yan
2014-06-01
(-)-Securinine (SE) is a major alkaloid found in plant Securinega suffruticosa, which has a wide range of pharmacological activities including anticancer, anti-parasitic and central nervous system stimulating effects, etc. To aid the pharmacological study of SE, we developed an LC-MS/MS method for quantitative determination of SE in mouse plasma. In this method, plasma samples were first prepared with salting-out assisted liquid-liquid extraction using cold acetonitrile (-20°C) and 2.00 M ammonium acetate. Separation of SE and the internal standard (IS) from sample matrix was achieved on a Gemini Nx C18 column using 40% acetonitrile and 60% 10.0mM ammonium acetate at a flow rate of 0.200 mL min(-1). Quantification of SE was accomplished with positive electrospray ionization tandem mass spectrometry using mass transitions m/z 218.1→84.1 for SE, and m/z 204.1→70.2 for the IS. This method has a lower limit of quantitation (LLOQ) of 0.600 ng mL(-1) and a linear calibration range up to 600 ng mL(-1) in mouse plasma. The intra- and inter-run accuracy (%RE) and precision (%CV) were ≤ ± 6% and 6%, respectively. The IS normalized matrix factors from six lots of plasma matrices ranged 0.92-1.07, and the recoveries of plasma SE were 99-109%. The validated method has been applied to the measurement of SE in plasma samples of a mouse study. Copyright © 2014 Elsevier B.V. All rights reserved.
A new LC-MS/MS bioanalytical method for perindopril and perindoprilat in human plasma and milk.
Lwin, Ei Mon Phyo; Gerber, Cobus; Song, Yunmei; Leggett, Catherine; Ritchie, Usha; Turner, Sean; Garg, Sanjay
2017-10-01
A first of its kind, simple, rapid, and sensitive liquid chromatography mass spectrometry (LC-MS/MS) method was developed and validated for quantification of perindopril and perindoprilat in both human plasma and breast milk. The analytes and internal standards (phenazone and acetyl salicylic acid) were extracted from biological matrices by protein precipitation. A Phenomenex® C-18 column was used to provide an appropriate chromatographic separation of the analytes, followed by detection with tandem mass spectrometry. Gradient chromatographic and mass spectrometric detection conditions with mobile phases (A: 5% methanol + 0.1% formic acid in water v/v, and B: 95% methanol + 0.1% formic acid in water v/v) were developed to achieve a LOQ of 0.5 ng/mL in both human plasma and milk. The method was suitable of evaluating clinical samples. The mass transition was followed as m/z 369.10/172.00 for perindopril, m/z 339.00/168.10 for perindoprilat, m/z 188.90/55.95 for phenazone, and m/z 179.04/137.02 for acetyl salicylic acid. The developed method was optimized and validated with a linear range of 0.1-200 ng/mL (r 2 = better than 0.99 for both perindopril and perindoprilat). The precision and accuracy values were within 15% CV. The overall recovery of the analytes was 80-110%. The method has good specificity and repeatability. Stability studies were conducted in both human plasma and bovine milk for up to 3 months, at the storage conditions of 25, 4, and -80 °C.
Ponce-Robles, Laura; Rivas, Gracia; Esteban, Belen; Oller, Isabel; Malato, Sixto; Agüera, Ana
2017-10-01
An analytical method was developed and validated for the determination of ten pesticides in sewage sludge coming from an agro-food industry. The method was based on the application of Quick, Easy, Cheap, Effective, Rugged, and Safe (QuEChERS) extraction for solid sewage sludge and SPE extraction for sludge aqueous phase, followed by liquid chromatography (LC) coupled to hybrid quadrupole/linear ion trap mass spectrometry (QqLIT-MS). The QuEChERS method was reported 14 years ago and nowadays is mainly applied to the analysis of pesticides in food. More recent applications have been reported in other matrices as sewage sludge, but the complexity of the matrix makes necessary the optimization of the cleanup step to improve the efficiency of the analysis. With this aim, several dispersive solid-phase extraction cleanup sorbents were tested, choosing C18 + PSA as a d-SPE sorbent. The proposed method was satisfactorily validated for most compounds investigated, showing recoveries higher than 80% in most cases, with the only exception of prochloraz (71%) at low concentration level. Limits of quantification were lower than 40 ng l -1 in the aqueous phase and below 40 ng g -1 in the solid phase for the majority of the analytes. The method was applied to solid sludge and the sludge aqueous phase coming from an agro-food industry which processes fruits and vegetables. Graphical abstract Application of LC/MS/MS advanced analytical techniques for determination of pesticides contained in sewage sludge.
Ediage, Emmanuel Njumbe; Di Mavungu, José Diana; Monbaliu, Sofie; Van Peteghem, Carlos; De Saeger, Sarah
2011-05-25
This study was designed to develop a sensitive liquid chromatography tandem mass spectrometry (LC-MS/MS) method for the simultaneous detection and quantification of 25 mycotoxins in cassava flour, peanut cake and maize samples with particular focus on the optimization of the sample preparation protocol and method validation. All 25 mycotoxins were extracted in a single step with a mixture of methanol/ethyl acetate/water (70:20:10, v/v/v). The method limits of quantification (LOQ) varied from 0.3 μg/kg to 106 μg/kg. Good precision and linearity were observed for most of the mycotoxins. The method was applied for the analysis of naturally contaminated peanut cake, cassava flour and maize samples from the Republic of Benin. All samples analyzed (fifteen peanut cakes, four maize flour and four cassava flour samples) tested positive for one or more mycotoxins. Aflatoxins (total aflatoxins; 10-346 μg/kg) and ochratoxin A (
Teitelbaum, Aaron M.; Flaker, Alicia M.; Kharasch, Evan D.
2016-01-01
A stereoselective analytical method was developed and validated for the quantification of bupropion, and principle metabolites hydroxybupropion, erythrohydrobupropion and threohydrobupropion in human plasma. Separation of individual enantiomers (R)-bupropion, (S)-bupropion, (R,R)-hydroxybupropion, (S,S-hydroxybupropion), (1S,2S)-threohydrobupropion, (1R,2R)-threohydrobupropion, (1R,2S)-erythrohydrobupropion, and (1S,2R)-erythrohydrobupropion was achieved utilizing an α1-acid glycoprotein column within a 12-minute run time. Chromatograph separation was significantly influenced by mobile phase pH and variability between columns. Analytes were quantified by positive ion electrospray tandem mass spectrometry following plasma protein precipitation with 20% trichloroacetic acid. Identification of erythrohydrobupropion enantiomer peaks and threohydrobupropion enantiomer peaks was achieved by sodium borohydride reduction of enantiopure (R)- and (S)-bupropion. Initial assay validation and sensitivity determination was on AB Sciex 3200, 4000 QTRAP, and 6500 mass spectrometers. Accuracy and precision were within 15% for each analyte. The assay was fully validated over analyte-specific concentrations using an AB Sciex 3200 mass spectrometer. Intra- and inter-assay precision and accuracy were within 12% for each analyte. The limits of quantification for bupropion (R and S), hydroxybupropion (R,R and S,S), threohydrobupropion (1S,2S and 1R,2R), and erythrohydrobupropion (1R,2S and 1S,2R) were 0.5, 2, 1, and 1 ng/mL, respectively. All analytes were stable following freeze thaw cycles at −80°C and while stored at 4°C in the instrument autosampler. This method was applicable to clinical pharmacokinetic investigations of bupropion in patients. This is the first chromatographic method to resolve erythrohydrobupropion and threohydrobupropion enantiomers, and the first stereoselective LC-MS/MS assay to quantify bupropion, and principle metabolites hydroxybupropion, erythrohydrobupropion, and threohydrobupropion in human plasma. PMID:26963497
Sullards, M. Cameron; Liu, Ying; Chen, Yanfeng; Merrill, Alfred H.
2011-01-01
Sphingolipids are a highly diverse category of molecules that serve not only as components of biological structures but also as regulators of numerous cell functions. Because so many of the structural features of sphingolipids give rise to their biological activity, there is a need for comprehensive or “sphingolipidomic” methods for identification and quantitation of as many individual subspecies as possible. This review defines sphingolipids as a class, briefly discusses classical methods for their analysis, and focuses primarily on liquid chromatography tandem mass spectrometry (LC-MS/MS) and tissue imaging mass spectrometry (TIMS). Recently, a set of evolving and expanding methods have been developed and rigorously validated for the extraction, identification, separation, and quantitation of sphingolipids by LC-MS/MS. Quantitation of these biomolecules is made possible via the use of an internal standard cocktail. The compounds that can be readily analyzed are free long-chain (sphingoid) bases, sphingoid base 1-phosphates, and more complex species such as ceramides, ceramide 1-phosphates, sphingomyelins, mono- and di-hexosylceramides sulfatides, and novel compounds such as the 1-deoxy- and 1-(deoxymethyl)-sphingoid bases and their N-acyl-derivatives. These methods can be altered slightly to separate and quantitate isomeric species such as glucosyl/galactosylceramide. Because these techniques require the extraction of sphingolipids from their native environment, any information regarding their localization in histological slices is lost. Therefore, this review also describes methods for TIMS. This technique has been shown to be a powerful tool to determine the localization of individual molecular species of sphingolipids directly from tissue slices. PMID:21749933
Bellur Atici, Esen; Yazar, Yücel; Ağtaş, Çağan; Ridvanoğlu, Nurten; Karlığa, Bekir
2017-03-20
Antibacterial combinations consisting of the semisynthetic antibiotic amoxicillin (amox) and the β-lactamase inhibitor potassium clavulanate (clav) are commonly used and several chromatographic methods were reported for their quantification in mixtures. In the present work, single HPLC method for related substances analyses of amoxicillin and potassium clavulanate mixtures was developed and validated according to international conference on harmonization (ICH) guidelines. Eighteen amoxicillin and six potassium clavulanate impurities were successfully separated from each other by using triple gradient elution using a Thermo Hypersil Zorbax BDS C18 (250 mm×4.6mm, 3μm) column with 50μL injection volumes at a wavelength of 215nm. Commercially unavailable impurities were formed by degradation of amoxicillin and potassium clavulanate, identified by LC-MS studies and used during analytical method development and validation studies. Also, process related amoxicillin impurity-P was synthesized and characterized by using nuclear magnetic resonance (NMR) and mass spectroscopy (MS) for the first time. As complementary of this work, an assay method for amoxicillin and potassium clavulanate mixtures was developed and validated; stress-testing and stability studies of amox/clav mixtures was carried out under specified conditions according to ICH and analyzed by using validated stability-indicating assay and related substances methods. Copyright © 2016 Elsevier B.V. All rights reserved.
Rubirola, Adrià; Boleda, Mª Rosa; Galceran, Mª Teresa
2017-04-14
This paper reports the development of a fully multiresidue and automated on-line solid phase extraction (SPE) - liquid chromatography tandem mass spectrometry (LC-MS/MS) method for the determination of 24 priority substances (PS) belonging to different classes (pesticides, hormones or pharmaceuticals) included in the Directive 2013/39/UE and the recent Watch List (Decision 2015/495) in water samples (drinking water, surface water, and effluent wastewaters). LC-MS/MS conditions and on-line SPE parameters such as sorbent type, sample and wash volumes were optimized. The developed method is highly sensitive (limits of detection between 0.1 and 1.4ngL -1 ) and precise (relative standard deviations lower than 8%). As part of the method validation studies, linearity, accuracy and matrix effects were assessed. The main advantage of this method over traditional off-line procedures is the minimization of tedious sample preparation increasing productivity and sample throughput. The optimized method was applied to the analysis of water samples and the results revealed the presence of 16 PS in river water and effluent water of wastewater treatment plants. Copyright © 2017 Elsevier B.V. All rights reserved.
Uclés, Ana; Herrera López, Sonia; Dolores Hernando, Maria; Rosal, Roberto; Ferrer, Carmen; Fernández-Alba, Amadeo R
2015-11-01
The use of yttria-stabilized zirconium dioxide nanoparticles as d-SPE clean-up sorbent for a rapid and sensitive liquid chromatography-electrospray ionization-tandem mass spectrometry (LC-ESI-MS/MS) method for the determination of post-harvest fungicides (carbaryl, carbendazim, chlorpropham, diphenylamine, ethoxyquin, flutriafol, imazalil, iprodione, methomyl, myclobutanil, pirimiphos-methyl, prochloraz, pyrimethanil, thiabendazole, thiophanate-methyl and tolclofos-methyl) in orange and pear samples has been evaluated and validated. The sample preparation was a modification of the QuEChERS extraction method using yttria-stabilized zirconium dioxide and multi-walled carbon nanotubes (MWCNTs) nanoparticles as the solid phase extraction (d-SPE) clean-up sorbents prior to injecting the ten-fold diluted extracts into the LC system. By using the yttria-stabilized zirconium dioxide extraction method, more recoveries in the 70-120% range were obtained - thus this method was used for the validation. Quantification was carried out using a matrix-matched calibration curve which was linear in the 1-500 µg kg(-1) range for almost all the pesticides studied. The validated limit of quantification was 10 µg kg(-1) for most of the studied compounds, except chlorpropham, ethoxyquin and thiophanate-methyl. Pesticide recoveries at the 10 and 100 µg kg(-1) concentration levels were satisfactory, with values between 77% and 120% and relative standard deviations (RSD) lower than 10% (n=5). The developed method was applied for the determination of selected fungicides in 20 real orange and pear samples. Four different pesticide residues were detected in 10 of these commodities; 20% of the samples contained pesticide residues at a quantifiable level (equal to or above the LOQs) for at least one pesticide residue. The most frequently-detected pesticide residues were: carbendazim, thiabendazole and imazalil-all were below the MRL. The highest concentration found was imazalil at 1175 µg kg(-1) in a pear sample. Copyright © 2015 Elsevier B.V. All rights reserved.
Khorram-Manesh, Amir; Berlin, Johan; Carlström, Eric
2016-01-01
The aim of the current review wasto study the existing knowledge about decision-making and to identify and describe validated training tools.A comprehensive literature review was conducted by using the following keywords: decision-making, emergencies, disasters, crisis management, training, exercises, simulation, validated, real-time, command and control, communication, collaboration, and multi-disciplinary in combination or as an isolated word. Two validated training systems developed in Sweden, 3 level collaboration (3LC) and MacSim, were identified and studied in light of the literature review in order to identify how decision-making can be trained. The training models fulfilled six of the eight identified characteristics of training for decision-making.Based on the results, these training models contained methods suitable to train for decision-making. PMID:27878123
Weiss, Gunter; Schlegel, Anne; Kottwitz, Denise; König, Thomas; Tetzner, Reimo
2017-01-01
Low-dose computed tomography (LDCT) is used for screening for lung cancer (LC) in high-risk patients in the United States. The definition of high risk and the impact of frequent false-positive results of low-dose computed tomography remains a challenge. DNA methylation biomarkers are valuable noninvasive diagnostic tools for cancer detection. This study reports on the evaluation of methylation markers in plasma DNA for LC detection and discrimination of malignant from nonmalignant lung disease. Circulating DNA was extracted from 3.5-mL plasma samples, treated with bisulfite using a commercially available kit, purified, and assayed by real-time polymerase chain reaction for assessment of DNA methylation of short stature homeobox 2 gene (SHOX2), prostaglandin E receptor 4 gene (PTGER4), and forkhead box L2 gene (FOXL2). In three independent case-control studies these assays were evaluated and optimized. The resultant assay, a triplex polymerase chain reaction combining SHOX2, PTGER4, and the reference gene actin, beta gene (ACTB), was validated using plasma from patients with and without malignant disease. A panel of SHOX2 and PTGER4 provided promising results in three independent case-control studies examining a total of 330 plasma specimens (area under the receiver operating characteristic curve = 91%-98%). A validation study with 172 patient samples demonstrated significant discriminatory performance in distinguishing patients with LC from subjects without malignancy (area under the curve = 0.88). At a fixed specificity of 90%, sensitivity for LC was 67%; at a fixed sensitivity of 90%, specificity was 73%. Measurement of SHOX2 and PTGER4 methylation in plasma DNA allowed detection of LC and differentiation of nonmalignant diseases. Development of a diagnostic test based on this panel may provide clinical utility in combination with current imaging techniques to improve LC risk stratification. Copyright © 2016 International Association for the Study of Lung Cancer. Published by Elsevier Inc. All rights reserved.
Shah, Kumar A; Peoples, Michael C; Halquist, Matthew S; Rutan, Sarah C; Karnes, H Thomas
2011-01-25
The work described in this paper involves development of a high-throughput on-line microfluidic sample extraction method using capillary micro-columns packed with MIP beads coupled with tandem mass spectrometry for the analysis of urinary NNAL. The method was optimized and matrix effects were evaluated and resolved. The method enabled low sample volume (200 μL) and rapid analysis of urinary NNAL by direct injection onto the microfluidic column packed with molecularly imprinted beads engineered to NNAL. The method was validated according to the FDA bioanalytical method validation guidance. The dynamic range extended from 20.0 to 2500.0 pg/mL with a percent relative error of ±5.9% and a run time of 7.00 min. The lower limit of quantitation was 20.0 pg/mL. The method was used for the analysis of NNAL and NNAL-Gluc concentrations in smokers' urine. Copyright © 2010 Elsevier B.V. All rights reserved.
Hubert, C; Lebrun, P; Houari, S; Ziemons, E; Rozet, E; Hubert, Ph
2014-01-01
The understanding of the method is a major concern when developing a stability-indicating method and even more so when dealing with impurity assays from complex matrices. In the presented case study, a Quality-by-Design approach was applied in order to optimize a routinely used method. An analytical issue occurring at the last stage of a long-term stability study involving unexpected impurities perturbing the monitoring of characterized impurities needed to be resolved. A compliant Quality-by-Design (QbD) methodology based on a Design of Experiments (DoE) approach was evaluated within the framework of a Liquid Chromatography (LC) method. This approach allows the investigation of Critical Process Parameters (CPPs), which have an impact on Critical Quality Attributes (CQAs) and, consequently, on LC selectivity. Using polynomial regression response modeling as well as Monte Carlo simulations for error propagation, Design Space (DS) was computed in order to determine robust working conditions for the developed stability-indicating method. This QbD compliant development was conducted in two phases allowing the use of the Design Space knowledge acquired during the first phase to define the experimental domain of the second phase, which constitutes a learning process. The selected working condition was then fully validated using accuracy profiles based on statistical tolerance intervals in order to evaluate the reliability of the results generated by this LC/ESI-MS stability-indicating method. A comparison was made between the traditional Quality-by-Testing (QbT) approach and the QbD strategy, highlighting the benefit of this QbD strategy in the case of an unexpected impurities issue. On this basis, the advantages of a systematic use of the QbD methodology were discussed. Copyright © 2013 Elsevier B.V. All rights reserved.
Peifer, Susanne; Schneider, Konstantin; Nürenberg, Gudrun; Volmer, Dietrich A; Heinzle, Elmar
2012-11-01
Intermediates of the purine biosynthesis pathway play key roles in cellular metabolism including nucleic acid synthesis and signal mediation. In addition, they are also of major interest to the biotechnological industry as several intermediates either possess flavor-enhancing characteristics or are applied in medical therapy. In this study, we have developed an analytical method for quantitation of 12 intermediates from the purine biosynthesis pathway including important nucleotides and their corresponding nucleosides and nucleobases. The approach comprised a single-step acidic extraction/quenching procedure, followed by quantitative electrospray LC-MS/MS analysis. The assay was validated in terms of accuracy, precision, reproducibility, and applicability for complex biological matrices. The method was subsequently applied for determination of free intracellular pool sizes of purine biosynthetic pathway intermediates in the two Gram-positive bacteria Corynebacterium glutamicum and Corynebacterium ammoniagenes. Importantly, no ion pair reagents were applied in this approach as usually required for liquid chromatography analysis of large classes of diverse metabolites.
Hertzog, Gabriel I; Soares, Karina L; Caldas, Sergiane S; Primel, Ednei G
2015-06-01
A procedure based on vortex-assisted matrix solid-phase dispersion (MSPD) for the extraction of 15 pharmaceuticals from fish samples with determination by liquid chromatography-tandem mass spectrometry (LC-MS/MS) was validated. Florisil, C18, diatomaceous earth, chitin, and chitosan were evaluated as solid supports. Best results were obtained with 0.5 g of diatomaceous earth, 0.5 g of sodium sulfate, and 5 mL of methanol. Analytical recoveries ranged from 58 to 128 % with relative standard deviation (RSD) lower than 15 %. Limit of quantification (LOQ) values for the 15 compounds ranged from 5 to 1000 ng g(-1). The method under investigation has shown to be a simple and fast extraction tool with minimum instrumentation and low amount of reagent, resulting in method low cost. Besides, alternative materials, such as chitin and chitosan, which were applied to the dispersion step for the first time, were found to be interesting alternatives.
Zhang, Gong; Huang, Guangwei; Xiao, Lu; Mitchell, Alyson E
2011-11-23
A sensitive and reliable LC-(ESI)MS/MS method was developed and validated for the simultaneous analysis of five common advanced glycation endproducts (AGEs) after enzymatic digestion in raw and roasted almonds. AGEs included carboxymethyl-lysine (CML), carboxyethyl-lysine (CEL), pyralline (Pyr), argpyrimidine (Arg-p), and pentosidine (Pento-s). This method allows accurate quantitation of free and AGE-protein adducts of target AGEs. Results indicate that CML and CEL are found in both raw and roasted almonds. Pyr was identified for the first time in roasted almonds and accounted for 64.4% of free plus bound measured AGEs. Arg-p and Pento-s were below the limit of detection in all almond samples tested. Free AGEs accounted for 1.3-26.8% of free plus bound measured AGEs, indicating that protein-bound forms predominate. The roasting process significantly increased CML, CEL, and Pyr formation, but no significant correlation was observed between these AGEs and roasting temperature.
NASA Astrophysics Data System (ADS)
Buchalla, Rainer; Begley, Timothy H.
2006-01-01
Low-molecular-weight (low-MW) constituents of polyethylene terephthalate (PET), irradiated with 60Co gamma rays at 25 and 50 kGy, were analyzed by HPLC-MS with atmospheric-pressure chemical ionization (APCI). Consistent with earlier results, the concentrations of the major compounds that are present in the non-irradiated PET do not change perceptibly. However, we find a small but significant increase in terephthalic acid ethylester, from less than 1 mg/kg in the non-irradiated control to ca. 2 mg/kg after 50 kGy, which has not been described before. The finding is important because it gives an impression of the sensitivity of the analytical method. Additionally, it shows that even very radiation-resistant polymers can form measurable amounts of low-MW radiolysis products. The potential and limitations of LC-MS for the analysis of radiolysis products and unidentified migrants are briefly discussed in the context of the question: How can we validate our analytical methods for unknown analytes?
Xu, Xiaohui Sophia; Rose, Anne; Demers, Roger; Eley, Timothy; Ryan, John; Stouffer, Bruce; Cojocaru, Laura; Arnold, Mark
2014-01-01
The determination of drug-protein binding is important in the pharmaceutical development process because of the impact of protein binding on both the pharmacokinetics and pharmacodynamics of drugs. Equilibrium dialysis is the preferred method to measure the free drug fraction because it is considered to be more accurate. The throughput of equilibrium dialysis has recently been improved by implementing a 96-well format plate. Results/methodology: This manuscript illustrates the successful application of a 96-well rapid equilibrium dialysis (RED) device in the determination of atazanavir plasma-protein binding. This RED method of measuring free fraction was successfully validated and then applied to the analysis of clinical plasma samples taken from HIV-infected pregnant women administered atazanavir. Combined with LC-MS/MS detection, the 96-well format equilibrium dialysis device was suitable for measuring the free and bound concentration of pharmaceutical molecules in a high-throughput mode.
Characterization of NIST food-matrix Standard Reference Materials for their vitamin C content.
Thomas, Jeanice B; Yen, James H; Sharpless, Katherine E
2013-05-01
The vitamin C concentrations in three food-matrix Standard Reference Materials (SRMs) from the National Institute of Standards and Technology (NIST) have been determined by liquid chromatography (LC) with absorbance detection. These materials (SRM 1549a Whole Milk Powder, SRM 1849a Infant/Adult Nutritional Formula, and SRM 3233 Fortified Breakfast Cereal) have been characterized to support analytical measurements made by food processors that are required to provide information about their products' vitamin C content on the labels of products distributed in the United States. The SRMs are primarily intended for use in validating analytical methods for the determination of selected vitamins, elements, fatty acids, and other nutrients in these materials and in similar matrixes. They can also be used for quality assurance in the characterization of test samples or in-house control materials, and for establishing measurement traceability. Within-day precision of the LC method used to measure vitamin C in the food-matrix SRMs characterized in this study ranged from 2.7% to 6.5%.
Chen, Buyun; Lu, Pingping; Freeman, Dugan; Gao, Yang; Choo, Edna; DeMent, Kevin; Savage, Scott; Zhang, Kelly; Milanwoski, Dennis; Liu, Lichuan; Dean, Brian; Deng, Yuzhong
2018-05-30
The pH labile metabolite, hydrophobicity, high oral dose and systematic exposure of GDC-0810 posed tremendous challenges to develop a LC-MS method for a stable isotope labeled aBA study. In this study, we explored practical solutions to balance stability and sensitivity and to cope with the impact of high C p.o. to C i.v. ratio on the labeling selection and assay dynamic range. A [ 13 C 9 ] GDC-0810 was synthesized to minimize the isotopic interference between PO dose, internal standard and I.V. microtracer. A highly sensitive LC-MS assay was validated for quantitation of [ 13 C 9 ] GDC-0810 from 5 to 1250 pg/mL. The optimized method was applied to a proof of concept cynomolgus monkey aBA study and the bioavailability calculated using microtracer dosing and regular dosing were similar to each other. Copyright © 2018 Elsevier B.V. All rights reserved.
Muñoz, Eva; Muñoz, Gloria; Pineda, Laura; Serrahima, Eulalia; Centrich, Francesc
2012-01-01
A multiresidue method based on GC or LC and MS or MS/MS for the determination of 204 pesticides in diverse food matrixes of animal and plant origin is described. The method can include different stages of cleanup according to the chemical characteristics of each sample. Samples were extracted using accelerated solvent extraction. Those with a high fat content or that contained chlorophyll required further purification by gel permeation chromatography and/or SPE (ENVI-Carb). The methodology developed here was fully validated; the LOQs for the 204 pesticides are presented. The LOQ values lie between 0.01 to 0.02 mg/kg. However, in some cases, mainly in baby food, they were as low as 0.003 mg/kg, thereby meeting European Union requirements on maximum residue levels for pesticides, as outlined in European regulation 396/2005 and the Commission Directive 2003/13/EC. The procedure has been accredited for a wide scope of pesticides and matrixes by the Spanish Accreditation Body (ENAC) following ISO/IEC 17025:2005, as outlined in ENAC technical note NT-19.
Development and validation of an LC-UV method for the determination of sulfonamides in animal feeds.
Kumar, P; Companyó, R
2012-05-01
A simple LC-UV method was developed for the determination of residues of eight sulfonamides (sulfachloropyridazine, sulfadiazine, sulfadimidine, sulfadoxine, sulfamethoxypyridazine, sulfaquinoxaline, sulfamethoxazole, and sulfadimethoxine) in six types of animal feed. C18, Oasis HLB, Plexa and Plexa PCX stationary phases were assessed for the clean-up step and the latter was chosen as it showed greater efficiency in the clean-up of interferences. Feed samples spiked with sulfonamides at 2 mg/kg were used to assess the trueness (recovery %) and precision of the method. Mean recovery values ranged from 47% to 66%, intra-day precision (RSD %) from 4% to 15% and inter-day precision (RSD %) from 7% to 18% in pig feed. Recoveries and intra-day precisions were also evaluated in rabbit, hen, cow, chicken and piglet feed matrices. Calibration curves with standards prepared in mobile phase and matrix-matched calibration curves were compared and the matrix effects were ascertained. The limits of detection and quantification in the feeds ranged from 74 to 265 µg/kg and from 265 to 868 µg/kg, respectively. Copyright © 2011 John Wiley & Sons, Ltd.
Malinsky, Michelle Duval; Jacoby, Cliffton B; Reagen, William K
2011-01-10
We report herein a simple protein precipitation extraction-liquid chromatography tandem mass spectrometry (LC/MS/MS) method, validation, and application for the analysis of perfluorinated carboxylic acids (C7-C12), perfluorinated sulfonic acids (C4, C6, and C8), and perfluorooctane sulfonamide (FOSA) in fish fillet tissue. The method combines a rapid homogenization and protein precipitation tissue extraction procedure using stable-isotope internal standard (IS) calibration. Method validation in bluegill (Lepomis macrochirus) fillet tissue evaluated the following: (1) method accuracy and precision in both extracted matrix-matched calibration and solvent (unextracted) calibration, (2) quantitation of mixed branched and linear isomers of perfluorooctanoate (PFOA) and perfluorooctanesulfonate (PFOS) with linear isomer calibration, (3) quantitation of low level (ppb) perfluorinated compounds (PFCs) in the presence of high level (ppm) PFOS, and (4) specificity from matrix interferences. Both calibration techniques produced method accuracy of at least 100±13% with a precision (%RSD) ≤18% for all target analytes. Method accuracy and precision results for fillet samples from nine different fish species taken from the Mississippi River in 2008 and 2009 are also presented. Copyright © 2010 Elsevier B.V. All rights reserved.
Paniagua, Ricardo; Campbell, Andrew; Changelian, Paul S; Reitz, Bruce A; Prakash, Chandra; Borie, Dominic C
2005-10-01
A fast and accurate method to quantify the new immunosuppressive JAK3 inhibitor CP-690,550 in whole blood using a dual-pump liquid chromatography-liquid chromatography-mass spectrometry (LC/LC-MS) system was developed and validated in nonhuman primate blood. Before injection, blood samples were prepared by precipitation with a reagent that included methanol and acetonitrile (30:70, vol/vol) along with the internal standard (CP-istd). Column-switching LC/LC-MS analysis used online extraction followed by separation on a C8 analytic column and MS detection of the [M + H] CP-690,550 (m/z = 313.1) and CP internal standard (m/z = 288.1). Linearity was always better than r = 0.99 (n = 7) for CP-690,550 (range 2.5-750 ng/mL), with a lower limit of quantification (LLOQ) of 2.5 ng/mL. The intrarun accuracy and precision ranged from 103.0% to 105.4% and 2.7% to 4.3%, respectively (n = 5), and the interday precision ranged from 8.7% to 11.1%, and the interday accuracy ranged from 98.1% to 103.8% of nominal values (n = 14). The injection repeatability for the method was 1.3% (n = 7). Except for the LLOQ, the intraday accuracy and precision in human blood were also within 15% (n = 5). The combination of simple sample preparation and short analytic run time of this sensitive procedure makes it effective for monitoring the concentration of CP-690,550 in whole blood in organ-transplant recipients.
Validation of an ultra-fast UPLC-UV method for the separation of antituberculosis tablets.
Nguyen, Dao T-T; Guillarme, Davy; Rudaz, Serge; Veuthey, Jean-Luc
2008-04-01
A simple method using ultra performance LC (UPLC) coupled with UV detection was developed and validated for the determination of antituberculosis drugs in combined dosage form, i. e. isoniazid (ISN), pyrazinamide (PYR) and rifampicin (RIF). Drugs were separated on a short column (2.1 mm x 50 mm) packed with 1.7 mum particles, using an elution gradient procedure. At 30 degrees C, less than 2 min was necessary for the complete separation of the three antituberculosis drugs, while the original USP method was performed in 15 min. Further improvements were obtained with the combination of UPLC and high temperature (up to 90 degrees C), namely HT-UPLC, which allows the application of higher mobile phase flow rates. Therefore, the separation of ISN, PYR and RIF was performed in less than 1 min. After validation (selectivity, trueness, precision and accuracy), both methods (UPLC and HT-UPLC) have proven suitable for the routine quality control analysis of antituberculosis drugs in combined dosage form. Additionally, a large number of samples per day can be analysed due to the short analysis times.
Hill, Ryan C; Oman, Trent J; Shan, Guomin; Schafer, Barry; Eble, Julie; Chen, Cynthia
2015-08-26
Currently, traditional immunochemistry technologies such as enzyme-linked immunosorbent assays (ELISA) are the predominant analytical tool used to measure levels of recombinant proteins expressed in genetically engineered (GE) plants. Recent advances in agricultural biotechnology have created a need to develop methods capable of selectively detecting and quantifying multiple proteins in complex matrices because of increasing numbers of transgenic proteins being coexpressed or "stacked" to achieve tolerance to multiple herbicides or to provide multiple modes of action for insect control. A multiplexing analytical method utilizing liquid chromatography with tandem mass spectrometry (LC-MS/MS) has been developed and validated to quantify three herbicide-tolerant proteins in soybean tissues: aryloxyalkanoate dioxygenase (AAD-12), 5-enol-pyruvylshikimate-3-phosphate synthase (2mEPSPS), and phosphinothricin acetyltransferase (PAT). Results from the validation showed high recovery and precision over multiple analysts and laboratories. Results from this method were comparable to those obtained with ELISA with respect to protein quantitation, and the described method was demonstrated to be suitable for multiplex quantitation of transgenic proteins in GE crops.
Granada, Andréa; Murakami, Fabio S; Sartori, Tatiane; Lemos-Senna, Elenara; Silva, Marcos A S
2008-01-01
A simple, rapid, and sensitive reversed-phase column high-performance liquid chromatographic method was developed and validated to quantify camptothecin (CPT) in polymeric nanocapsule suspensions. The chromatographic separation was performed on a Supelcosil LC-18 column (15 cm x 4.6 mm id, 5 microm) using a mobile phase consisting of methanol-10 mM KH2PO4 (60 + 40, v/v; pH 2.8) at a flow rate of 1.0 mL/min and ultraviolet detection at 254 nm. The calibration graph was linear from 0.5 to 3.0 microg/mL with a correlation coefficient of 0.9979, and the limit of quantitation was 0.35 microg/mL. The assay recovery ranged from 97.3 to 105.0%. The intraday and interday relative standard deviation values were < 5.0%. The validation results confirmed that the developed method is specific, linear, accurate, and precise for its intended use. The current method was successfully applied to the evaluation of CPT entrapment efficiency and drug content in polymeric nanocapsule suspensions during the early stage of formulation development.
Hufnagel, P.; Glandorf, J.; Körting, G.; Jabs, W.; Schweiger-Hufnagel, U.; Hahner, S.; Lubeck, M.; Suckau, D.
2007-01-01
Analysis of complex proteomes often results in long protein lists, but falls short in measuring the validity of identification and quantification results on a greater number of proteins. Biological and technical replicates are mandatory, as is the combination of the MS data from various workflows (gels, 1D-LC, 2D-LC), instruments (TOF/TOF, trap, qTOF or FTMS), and search engines. We describe a database-driven study that combines two workflows, two mass spectrometers, and four search engines with protein identification following a decoy database strategy. The sample was a tryptically digested lysate (10,000 cells) of a human colorectal cancer cell line. Data from two LC-MALDI-TOF/TOF runs and a 2D-LC-ESI-trap run using capillary and nano-LC columns were submitted to the proteomics software platform ProteinScape. The combined MALDI data and the ESI data were searched using Mascot (Matrix Science), Phenyx (GeneBio), ProteinSolver (Bruker and Protagen), and Sequest (Thermo) against a decoy database generated from IPI-human in order to obtain one protein list across all workflows and search engines at a defined maximum false-positive rate of 5%. ProteinScape combined the data to one LC-MALDI and one LC-ESI dataset. The initial separate searches from the two combined datasets generated eight independent peptide lists. These were compiled into an integrated protein list using the ProteinExtractor algorithm. An initial evaluation of the generated data led to the identification of approximately 1200 proteins. Result integration on a peptide level allowed discrimination of protein isoforms that would not have been possible with a mere combination of protein lists.
Schläfli, A M; Berezowska, S; Adams, O; Langer, R; Tschan, M P
2015-05-05
Autophagy assures cellular homeostasis, and gains increasing importance in cancer, where it impacts on carcinogenesis, propagation of the malignant phenotype and development of resistance. To date, its tissue-based analysis by immunohistochemistry remains poorly standardized. Here we show the feasibility of specifically and reliably assessing the autophagy markers LC3B and p62 (SQSTM1) in formalin fixed and paraffin embedded human tissue by immunohistochemistry. Preceding functional experiments consisted of depleting LC3B and p62 in H1299 lung cancer cells with subsequent induction of autophagy. Western blot and immunofluorescence validated antibody specificity, knockdown efficiency and autophagy induction prior to fixation in formalin and embedding in paraffin. LC3B and p62 antibodies were validated on formalin fixed and paraffin embedded cell pellets of treated and control cells and finally applied on a tissue microarray with 80 human malignant and non-neoplastic lung and stomach formalin fixed and paraffin embedded tissue samples. Dot-like staining of various degrees was observed in cell pellets and 18/40 (LC3B) and 22/40 (p62) tumors, respectively. Seventeen tumors were double positive for LC3B and p62. P62 displayed additional significant cytoplasmic and nuclear staining of unknown significance. Interobserver-agreement for grading of staining intensities and patterns was substantial to excellent (kappa values 0.60 - 0.83). In summary, we present a specific and reliable IHC staining of LC3B and p62 on formalin fixed and paraffin embedded human tissue. Our presented protocol is designed to aid reliable investigation of dysregulated autophagy in solid tumors and may be used on large tissue collectives.
Zhang, Daping; Wu, Lei; Chow, Diana S-L; Tam, Vincent H; Rios, Danielle R
2016-01-05
The determination of dopamine facilitates better understanding of the complex brain disorders in the central nervous system and the regulation of endocrine system, cardiovascular functions and renal functions in the periphery. The purpose of this study was to develop a highly sensitive and reliable assay for the quantification of dopamine in human neonate plasma. Dopamine was extracted from human plasma by strong cation exchange (SCX) solid phase extraction (SPE), and subsequently derivatized with propionic anhydride. The derivatized analyte was separated by a Waters Acquity UPLC BEH C18 column using gradient elution at 0.4 ml/min with mobile phases A (0.2% formic acid in water [v/v]) and B (MeOH-ACN [v/v, 30:70]). Analysis was performed under positive electrospray ionization tandem mass spectrometer (ESI-MS/MS) in the multiple reaction monitoring (MRM) mode. The stable and relatively non-polar nature of the derivatized analyte enables reliable quantification of dopamine in the range of 10-1000 pg/ml using 200 μl of plasma sample. The method was validated with intra-day and inter-day precision less than 7%, and the intra-day and inter-day accuracy of 91.9-101.9% and 92.3-102.6%, respectively. The validated assay was applied to quantify dopamine levels in two preterm neonate plasma samples. In conclusion, a sensitive and selective LC-MS/MS method has been developed and validated, and successfully used for the determination of plasma dopamine levels in preterm neonates. Copyright © 2015 Elsevier B.V. All rights reserved.
Giordano, Lucia; Coletta, Walter; Rapisarda, Paolo; Donati, Maria Benedetta; Rotilio, Domenico
2007-12-01
Blood orange juice has a high content in anthocyanins, especially represented by delphinidin-3-glucoside (D3G), cyanidin-3-glucoside (C3G) and cyanidin-3-(6-malonylglucoside) (CMG). An LC-MS/MS method for the simultaneous determination of D3G and C3G in human plasma and urine was developed and validated. After sample preparation by SPE, chromatographic separation was performed with an RP-C(18) column, using a water/methanol linear gradient. The quantitation of target compounds was determined by multiple reaction monitoring (MRM) mode, using ESI. The method showed good selectivity, sensitivity (LOD = 0.05 and 0.10 ng/mL for C3G in plasma and urine, respectively; LOD = 0.10 ng/mL for D3G in plasma and urine), linearity (0.20-200 ng/mL; r >or= 0.998), intra- and interday precision and accuracy (
Imbert, L; Dulaurent, S; Mercerolle, M; Morichon, J; Lachâtre, G; Gaulier, J-M
2014-01-01
The two major challenges in hair analysis are the limited amount of samples usually available and the low targeted concentrations. To overcome these limitations, a liquid chromatography-electrospray-tandem mass spectrometry method (LC-ESI-MS/MS) allowing the simultaneous analysis of 17 amphetamines (amphetamine, BDB, m-CPP, dexfenfluramine, DOB, DOM, ephedrine, MBDB, MDA, MDEA, MDMA, methamphetamine, methylphenidate, 4-MTA, norephedrine, norfenfluramine and PMA), 5 opiates (morphine, codeine, heroin, ethylmorphine, and 6AM), cocaine and 5 metabolites [ecgonine methyl ester (EME), benzoylecgonine (BZE), anhydroecgonine methyl ester (AME), cocaethylene, and norcocaine] has been developed. The validation procedure included linearity, intra-day and inter-day variability and accuracy for 5 days (5 replicates at 3 concentration levels). Proficiency studies were used to check the accuracy of the method. As a result, all amphetamines, opiates and cocaine derivatives were satisfactory identified by 2 MRM transitions in 15 min. Calibration curves were performed by a quadratic 1/X weighted regression. The calibration model fits from 0.05 to 10 ng/mg. The limits of detection (LODs) range between 0.005 and 0.030 ng/mg. Precision has been checked by intra-day and inter-day RSD, and associated relative bias, which were lower than 25% for the limits of quantifications (LOQs) and lower than 20% for the other levels tested. This method was routinely applied to hair samples: two positive results of adult drug addicts are presented. Copyright © 2013 Elsevier Ireland Ltd. All rights reserved.
Genualdi, Susie; MacMahon, Shaun; Robbins, Katherine; Farris, Samantha; Shyong, Nicole; DeJager, Lowri
2016-01-01
Sudan I, II, III and IV dyes are banned for use as food colorants in the United States and European Union because they are toxic and carcinogenic. These dyes have been illegally used as food additives in products such as chilli spices and palm oil to enhance their red colour. From 2003 to 2005, the European Union made a series of decisions requiring chilli spices and palm oil imported to the European Union to contain analytical reports declaring them free of Sudan I–IV. In order for the USFDA to investigate the adulteration of palm oil and chilli spices with unapproved colour additives in the United States, a method was developed for the extraction and analysis of Sudan dyes in palm oil, and previous methods were validated for Sudan dyes in chilli spices. Both LC-DAD and LC-MS/MS methods were examined for their limitations and effectiveness in identifying adulterated samples. Method validation was performed for both chilli spices and palm oil by spiking samples known to be free of Sudan dyes at concentrations close to the limit of detection. Reproducibility, matrix effects, and selectivity of the method were also investigated. Additionally, for the first time a survey of palm oil and chilli spices was performed in the United States, specifically in the Washington, DC, area. Illegal dyes, primarily Sudan IV, were detected in palm oil at concentrations from 150 to 24 000 ng ml−1. Low concentrations (< 21 μg kg−1) of Sudan dyes were found in 11 out of 57 spices and are most likely a result of cross-contamination during preparation and storage and not intentional adulteration. PMID:26824489
Genualdi, Susie; MacMahon, Shaun; Robbins, Katherine; Farris, Samantha; Shyong, Nicole; DeJager, Lowri
2016-01-01
Sudan I, II, III and IV dyes are banned for use as food colorants in the United States and European Union because they are toxic and carcinogenic. These dyes have been illegally used as food additives in products such as chilli spices and palm oil to enhance their red colour. From 2003 to 2005, the European Union made a series of decisions requiring chilli spices and palm oil imported to the European Union to contain analytical reports declaring them free of Sudan I-IV. In order for the USFDA to investigate the adulteration of palm oil and chilli spices with unapproved colour additives in the United States, a method was developed for the extraction and analysis of Sudan dyes in palm oil, and previous methods were validated for Sudan dyes in chilli spices. Both LC-DAD and LC-MS/MS methods were examined for their limitations and effectiveness in identifying adulterated samples. Method validation was performed for both chilli spices and palm oil by spiking samples known to be free of Sudan dyes at concentrations close to the limit of detection. Reproducibility, matrix effects, and selectivity of the method were also investigated. Additionally, for the first time a survey of palm oil and chilli spices was performed in the United States, specifically in the Washington, DC, area. Illegal dyes, primarily Sudan IV, were detected in palm oil at concentrations from 150 to 24 000 ng ml(-1). Low concentrations (< 21 µg kg(-1)) of Sudan dyes were found in 11 out of 57 spices and are most likely a result of cross-contamination during preparation and storage and not intentional adulteration.
Madry, Milena M; Spycher, Barbara S; Kupper, Jacqueline; Fuerst, Anton; Baumgartner, Markus R; Kraemer, Thomas; Naegeli, Hanspeter
2016-06-01
Compared to blood or urine, drugs can be detected for much longer periods in the long hair of horses. The aim of this study was to establish and validate a highly sensitive liquid chromatography tandem mass spectrometry (LC-MS/MS) method for the detection and quantification of frequently prescribed opioids, sedatives and non-steroidal anti-inflammatory agents in the mane and tail hair of horses. Based on an average growth rate of about 2 cm per month, times of administration reported by horse owners or veterinary physicians were related to drug localizations in hair. Hair samples were collected from ten horses that received drug treatments and analyzed in segments of 2, 4 or 6 cm in length. Hair segments were decontaminated, cut into fragments and methanol-extracted under sonication. The extracts were analyzed by LC-MS/MS for 13 commonly used drugs using the validated procedure. Deuterated analogs were included as internal standards. Analytes were detected in hair samples with a length of up to 70 cm. Fourteen out of 16 hair samples were positive for at least one of the tested drugs. Segmentation allowed for time-resolved monitoring of periods of 1 to 3 months of drug administration. Concentrations in dark hair reached a maximum of 4.0 pg/mg for butorphanol, 6.0 pg/mg for tramadol, 1.4 pg/mg for morphine, 1.8 pg/mg for detomidine, 1.2 pg/mg for acepromazine, 39 pg/mg for flunixin, 5.0 pg/mg for firocoxib, and 3'600 pg/mg for phenylbutazone. Only trace amounts of meloxicam were detected. Drug detection correlated well with the reported period of medical treatment. No analytes were detected in the light-colored mane and tail hair samples from one horse despite preceding administrations of acepromazine and phenylbutazone. This study describes a sensitive and selective technique suitable for the validated detection and quantification of frequently prescribed veterinary drugs in horse hair. The segmental method can be applied for time-resolved long-term retrospective drug monitoring, for example in prepurchase examinations of horses as drug detection in hair can prove preceding medical treatments.
New 3D-printed sorbent for extraction of steroids from human plasma preceding LC-MS analysis.
Konieczna, Lucyna; Belka, Mariusz; Okońska, Magdalena; Pyszka, Magdalena; Bączek, Tomasz
2018-04-13
In recent years, there has been an increasing worldwide interest in the use of alternative sample preparation methods that are proceeded by separation techniques. Fused deposition modeling (FDM) is a 3D printing technique that is based the consecutive layering of softened/melted thermoplastic materials. In this study, a group of natural steroids and sexual hormones - namely, aldosterone, cortisol, β-estradiol, testosterone, dihydrotestosterone, and synthetic methyltestosterone and betamethasone - were separated and determined using an optimized high-performance liquid chromatography coupled to mass spectrometry (LC-MS) method in positive ionization mode. 3D-printed sorbents were selected as the pre-concentration technique because they are generally low cost, fast, and simple to make and automate. Furthermore, the use of 3D-printed sorbents helps to minimize potential errors due to their repeatability and reproducibility, and their ability to eliminate carry over by using one printed sorbent for a single extraction of steroids from biological matrices. The extraction procedure was optimized and the parameters influencing 3D-printed Layfomm 60 ® based sorbent and LC-MS were studied, including the type of extraction solvent used, sorption and desorption times, temperature, and the salting-out effect. To demonstrate this method's applicability for biological sample analysis, the SPME-LC-MS method was validated for its ability to simultaneously quantify endogenous steroids. This evaluation confirmed good linearity and an R 2 that was between 0.9970 and 0.9990. The recovery rates for human plasma samples were 86.34-93.6% for the studied steroids with intra- and inter-day RSDs of 1.44-7.42% and 1.44-9.46%, respectively. To our knowledge, this study is the first time that 3D-printed sorbents have been used to extract trace amounts of endogenous low-molecular-weight compounds, such as steroids, from biological samples, such as plasma. Copyright © 2018 Elsevier B.V. All rights reserved.
Giménez, Estela; Juan, M Emília; Calvo-Melià, Sara; Barbosa, José; Sanz-Nebot, Victoria; Planas, Joana M
2015-09-04
Pentacyclic triterpenes are gaining interest due to their beneficial health effects, as anti-inflammatory, anti-diabetic and anti-tumoral, among others. In this study, an analytical LC-MS method was developed for the simultaneous determination of maslinic, oleanolic and ursolic acids along with erythrodiol and uvaol, which are the main triterpenic compounds present in the fruits and leaves of Olea europaea L. A Zorbax Eclipse PAH column at 30°C with mobile phase of water (17%) and methanol (83%) at 0.8mL/min conformed the optimal chromatographic conditions that allowed the separation of the compounds of interest, two pairs of which are isomers differing only in the position of one methyl group (oleanolic-ursolic and erythrodiol-uvaol). The ionization was performed in an APCI source at 450°C programmed in negative mode for the triterpenic acids, and in positive for the alcohols. An ion trap (LC-IT-MS) and a triple quadrupole (LC-QqQ-MS) were assessed for maximal sensitivity that was achieved with LC-QqQ-MS. The LODs of triterpenic acids were lower than 1nM, whereas for erythrodiol and uvaol were 4.5 and 7.5nM, respectively. The method was linear for the five analytes in the range of concentrations from 0.005 to 15μM with correlation coefficients exceeding 0.99. The precision and accuracy were ≤9.90% and ≤9.57%, respectively. The applicability of the validated method was assessed in the analysis of the pentacyclic triterpenes in Marfil table olives, after the optimization of the extraction procedure. The developed method constitutes the first step for future studies of triterpenic compounds present in foods that would allow establishing their effects on human health. Copyright © 2015 Elsevier B.V. All rights reserved.
Székely, György; Henriques, Bruno; Gil, Marco; Alvarez, Carlos
2014-09-01
This paper discusses a design of experiments (DoE) assisted optimization and robustness testing of a liquid chromatography-tandem mass spectrometry (LC-MS/MS) method development for the trace analysis of the potentially genotoxic 1,3-diisopropylurea (IPU) impurity in mometasone furoate glucocorticosteroid. Compared to the conventional trial-and-error method development, DoE is a cost-effective and systematic approach to system optimization by which the effects of multiple parameters and parameter interactions on a given response are considered. The LC and MS factors were studied simultaneously: flow (F), gradient (G), injection volume (Vinj), cone voltage (E(con)), and collision energy (E(col)). The optimization was carried out with respect to four responses: separation of peaks (Sep), peak area (A(p)), length of the analysis (T), and the signal-to-noise ratio (S/N). An optimization central composite face (CCF) DoE was conducted leading to the early discovery of carry-over effect which was further investigated in order to establish the maximum injectable sample load. A second DoE was conducted in order to obtain the optimal LC-MS/MS method. As part of the validation of the obtained method, its robustness was determined by conducting a fractional factorial of resolution III DoE, wherein column temperature and quadrupole resolution were considered as additional factors. The method utilizes a common Phenomenex Gemini NX C-18 HPLC analytical column with electrospray ionization and a triple quadrupole mass detector in multiple reaction monitoring (MRM) mode, resulting in short analyses with a 10-min runtime. The high sensitivity and low limit of quantification (LOQ) was achieved by (1) MRM mode (instead of single ion monitoring) and (2) avoiding the drawbacks of derivatization (incomplete reaction and time-consuming sample preparation). Quantitatively, the DoE method development strategy resulted in the robust trace analysis of IPU at 1.25 ng/mL absolute concentration corresponding to 0.25 ppm LOQ in 5 g/l mometasone furoate glucocorticosteroid. Validation was carried out in a linear range of 0.25-10 ppm and presented a relative standard deviation (RSD) of 1.08% for system precision. Regarding IPU recovery in mometasone furoate, spiked samples produced recoveries between 96 and 109 % in the range of 0.25 to 2 ppm. Copyright © 2013 John Wiley & Sons, Ltd.
Kaufmann, Anton; Maden, Kathryn
2018-03-01
A quantitative method for the determination of biogenic amines was developed. The method is characterized by the virtual absence of sample cleanup and does not require a derivatization reaction. Diluted extracts are centrifuged, filtrated, and directly injected into an ultra-HPLC column, which is coupled to a single-stage high-resolution mass spectrometer (Orbitrap). The chromatography is based on a reversed-phase column and an eluent containing an ion-pairing agent (heptafluorobutyric acid). The high sensitivity of the instrument permits the injection of very diluted extracts, which ensures stable retention times and the virtual absence of signal suppression effects. In addition, the quantification of histamine (a regulated compound) is further aided by the use of an isotopically labeled internal standard. The method was validated for three fish-based matrixes. Both the sample processing and the analytical measurement are very fast; hence, the methodology is ideal for high-throughput work. In addition, the method is significantly more selective than conventional methods (i.e., derivatization followed by LC with UV/fluorescence (FL) detection) for biogenic amines. A comparison showed that LC-UV/FL methods can produce false-positive findings due to coeluting matrix compounds.
Chhonker, Yashpal S; Sleightholm, Richard L; Li, Jing; Oupický, David; Murry, Daryl J
2018-01-01
Hydroxychloroquine (HCQ) has been shown to disrupt autophagy and sensitize cancer cells to radiation and chemotherapeutic agents. However, the optimal delivery method, dose, and tumor concentrations required for these effects are not known. This is in part due to a lack of sensitive and reproducible analytical methods for HCQ quantitation in small animals. As such, we developed and validated a selective and sensitive liquid chromatography coupled with tandem mass spectrometry (LC-MS/MS) method for simultaneous quantitation of hydroxychloroquine and its metabolites in mouse blood and tissues. The chromatographic separation and detection of analytes were achieved on a reversed phase Thermo Aquasil C 18 (50×4.6mm, 3μ) column, with gradient elution using 0.2% formic acid and 0.1% formic acid in methanol as mobile phase at a flow rate of 0.5mL/min. Simple protein precipitation was utilized for extraction of analytes from the desired matrix. Analytes were separated and quantitated using MS/MS with an electrospray ionization source in positive multiple reaction monitoring (MRM) mode. The MS/MS response was linear over the concentration range from 1 to 2000ng/mL for all analytes with a correlation coefficient (R 2 ) of 0.998 or better. The within- and between-day precision (relative standard deviation, % RSD) and accuracy were within the acceptable limits per FDA guidelines. The validated method was successfully applied to a preclinical pharmacokinetic mouse study involving low volume blood and tissue samples for hydroxychloroquine and metabolites. Copyright © 2017 Elsevier B.V. All rights reserved.
Suraj, Joanna; Kurpińska, Anna; Olkowicz, Mariola; Niedzielska-Andres, Ewa; Smolik, Magdalena; Zakrzewska, Agnieszka; Jasztal, Agnieszka; Sitek, Barbara; Chlopicki, Stefan; Walczak, Maria
2018-02-05
The objective of this study was to develop and validate the method based on micro-liquid chromatography-tandem mass spectrometry (microLC/MS-MRM) for simultaneous determination of adiponectin (ADN), von Willebrand factor (vWF), soluble form of vascular cell adhesion molecule 1 (sVCAM-1), soluble form of intercellular adhesion molecule 1 (sICAM-1) and syndecan-1 (SDC-1) in mouse plasma. The calibration range was established from 2.5pmol/mL to 5000pmol/mL for ADN; 5pmol/mL to 5000pmol/mL for vWF; 0.375pmol/mL to 250pmol/mL for sVCAM-1 and sICAM-1; and 0.25pmol/mL to 250pmol/mL for SDC-1. The method was applied to measure the plasma concentration of selected proteins in mice fed high-fat diet (HFD), and revealed the pro-thrombotic status by increased concentration of vWF (1.31±0.17 nmol/mL (Control) vs 1.98±0.09 nmol/mL (HFD), p <0.05) and the dysregulation of adipose tissue metabolism by decreased concentration of ADN (0.62±0.08 nmol/mL (Control) vs 0.37±0.06 nmol/mL (HFD), p <0.05). In conclusion, the microLC/MS-MRM-based method allows for reliable measurements of selected protein biomarkers of endothelial dysfunction in mouse plasma. Copyright © 2017 Elsevier B.V. All rights reserved.
Xu, Mingzhen; Ni, Yang; Li, Shihong; Du, Juan; Li, Huqun; Zhou, Ying; Li, Weiyong; Chen, Hui
2016-08-01
A simple liquid chromatography-tandem mass spectrometry (LC-MS/MS) method was firstly developed and validated for simultaneous determination of netupitant and palonosetron in human plasma using ibrutinib as the internal standard (IS). Following liquid-liquid extraction, the compounds were eluted isocratically on a Phenomenex C18 column (50mm×2.0mm, 3μm) with the mobile phase consisting of acetonitrile and 10mM ammonium acetate buffer (pH 9.0) (89:11, v/v) at the flow rate of 0.3mL/min. The monitored ion transitions were m/z 579.5→522.4 for netupitant, m/z 297.3→110.2 for palonosetron and m/z 441.2→138.1 for IS. Chromatographic run time was 2.5min per injection, which made it possible to analyze more than 300 of samples per day. The assay exhibited a linear dynamic range of 5-1000ng/mL for netupitant and 0.02-10ng/mL for palonosetron in plasma. The values for both within- and between-day precision and accuracy were well within the generally accepted criteria for analytical methods (<15%). Selectivity, linearity, lower limit of quantification (LLOQ), accuracy, precision, stability, matrix effect, recovery and carry-over effect were evaluated for all analytes. The method is simple, rapid, and has been applied successfully to a pharmacokinetic study of netupitant and palonosetron in healthy volunteers. Copyright © 2016 Elsevier B.V. All rights reserved.
Feng, Ye; Kunos, Charles A; Xu, Yan
2015-09-01
Triapine is an inhibitor of ribonucleotide reductase (RNR). Studies have shown that triapine significantly decreases the activity of RNR and enhanced the radiation-mediated cytotoxicity in cervical and colon cancer. In this work, we have developed and validated a selective and sensitive LC-MS/MS method for the determination of triapine in human plasma. In this method, 2-[(3-fluoro-2-pyridinyl)methylene] hydrazinecarbothioamide (NSC 266749) was used as the internal standard (IS); plasma samples were prepared by deproteinization with acetonitrile; tripaine and the IS were separated on a Waters Xbridge Shield RP18 column (3.5 µm; 2.1 × 50 mm) using a mobile phase containing 25.0% methanol and 75.0% ammonium bicarbonate buffer (10.0 mM, pH 8.50; v/v); column eluate was monitored by positive turbo-ionspray tandem mass spectrometry; and quantitation of triapine was carried out in multiple-reaction-monitoring mode. The method developed had a linear calibration range of 0.250-50.0 ng/mL with correlation coefficient of 0.999 for triapine in human plasma. The IS-normalized recovery and the IS-normalized matrix factor of triapine were 101-104% and 0.89-1.05, respectively. The accuracy expressed as percentage error and precision expressed as coefficient of variation were ≤±6 and ≤8%, respectively. The validated LC-MS/MS method was applied to the measurement of triapine in patient samples from a phase I clinical trial. Copyright © 2015 John Wiley & Sons, Ltd.
Jing, Wei; Thompson, Joseph J; Jacobs, Wesley A; Salvati, Louis M
2015-01-01
A single-laboratory validation (SLV) has been performed for a method that simultaneously determines choline and carnitine in nutritional products by ultra performance LC (UPLC)/MS/MS. All 11 matrixes from the AOAC Stakeholder Panel on Infant Formula and Adult Nutritionals (SPIFAN) were tested. Depending on the sample preparation, either the added (free, with a water dilution and filtering) or total (after microwave digestion at 120°C in nitric acid and subsequent neutralization with ammonia) species can be detected. For nonmilk containing products, the total carnitine is almost always equal to the free carnitine. A substantial difference was noted between free and total choline in all products. All Standard Method Performance Requirements for carnitine and choline have been met. This report summarizes the material sent to the AOAC Expert Review Panel for SPIFAN nutrient methods for the review of this method, as well as some additional data from an internal validation. The method was granted AOAC First Action status for carnitine in 2014 (2014.04), but the choline data are also being presented. A comparison of choline results to those from other AOAC methods is given.
Giebułtowicz, Joanna; Kojro, Grzegorz; Piotrowski, Roman; Kułakowski, Piotr; Wroczyński, Piotr
2016-09-05
Cloud-point extraction (CPE) is attracting increasing interest in a number of analytical fields, including bioanalysis, as it provides a simple, safe and environmentally-friendly sample preparation technique. However, there are only few reports on the application of this extraction technique in liquid chromatography-electrospray ionization-tandem mass spectrometry (LC-ESI-MS/MS) analysis. In this study, CPE was used for the isolation of antazoline from human plasma. To date, only one method of antazoline isolation from plasma exists-liquid-liquid extraction (LLE). The aim of this study was to prove the compatibility of CPE and LC-ESI-MS/MS and the applicability of CPE to the determination of antazoline in spiked human plasma and clinical samples. Antazoline was isolated from human plasma using Triton X-114 as a surfactant. Xylometazoline was used as an internal standard. NaOH concentration, temperature and Triton X-114 concentration were optimized. The absolute matrix effect was carefully investigated. All validation experiments met international acceptance criteria and no significant relative matrix effect was observed. The compatibility of CPE and LC-ESI-MS/MS was confirmed using clinical plasma samples. The determination of antazoline concentration in human plasma in the range 10-2500ngmL(-1) by the CPE method led to results which are equivalent to those obtained by the widely used liquid-liquid extraction method. Copyright © 2016 Elsevier B.V. All rights reserved.
Andersen, David W; Linnet, Kristian
2014-01-01
A screening method for 18 frequently measured exogenous anabolic steroids and the testosterone/epitestosterone (T/E) ratio in forensic cases has been developed and validated. The method involves a fully automated sample preparation including enzyme treatment, addition of internal standards and solid phase extraction followed by analysis by liquid chromatography-tandem mass spectrometry (LC-MS-MS) using electrospray ionization with adduct formation for two compounds. Urine samples from 580 forensic cases were analyzed to determine the T/E ratio and occurrence of exogenous anabolic steroids. Extraction recoveries ranged from 77 to 95%, matrix effects from 48 to 78%, overall process efficiencies from 40 to 54% and the lower limit of identification ranged from 2 to 40 ng/mL. In the 580 urine samples analyzed from routine forensic cases, 17 (2.9%) were found positive for one or more anabolic steroids. Only seven different steroids including testosterone were found in the material, suggesting that only a small number of common steroids are likely to occur in a forensic context. The steroids were often in high concentrations (>100 ng/mL), and a combination of steroids and/or other drugs of abuse were seen in the majority of cases. The method presented serves as a fast and automated screening procedure, proving the suitability of LC-MS-MS for analyzing anabolic steroids. © The Author 2014. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.
Jager, Nynke Gl; Rosing, Hilde; Schellens, Jan Hm; Beijnen, Jos H
2014-01-01
We developed an HPLC-MS/MS method to quantify tamoxifen (2.5-250 ng/ml) and its metabolite (Z)-endoxifen (0.5-50 ng/ml) in dried blood spots. Extraction recovery of both analytes from Whatman DMPK-A cards was 100% and consistent over time, however, recovery of (Z)-endoxifen from Whatman 903 cards was incomplete and increased upon storage. When SDS, a constituent of the DMPK-A coating, was present during the extraction, recovery improved. The method using DMPK-A cards was validated using bioanalytical guidelines. Additionally, influence of haematocrit (0.29-0.48 L/L), spot volume (20-50 µl) and homogeneity was within limits and both analytes were stable in DBS for at least 4 months. The method for the quantification of tamoxifen and (Z)-endoxifen in DBS collected on DMPK-A cards was successfully validated.
Wang, Shunhai; Bobst, Cedric E.; Kaltashov, Igor A.
2018-01-01
Transferrin (Tf) is an 80 kDa iron-binding protein which is viewed as a promising drug carrier to target the central nervous system due to its ability to penetrate the blood-brain barrier (BBB). Among the many challenges during the development of Tf-based therapeutics, sensitive and accurate quantitation of the administered Tf in cerebrospinal fluid (CSF) remains particularly difficult due to the presence of abundant endogenous Tf. Herein, we describe the development of a new LC-MS based method for sensitive and accurate quantitation of exogenous recombinant human Tf in rat CSF. By taking advantage of a His-tag present in recombinant Tf and applying Ni affinity purification, the exogenous hTf can be greatly enriched from rat CSF, despite the presence of the abundant endogenous protein. Additionally, we applied a newly developed O18-labeling technique that can generate internal standards at the protein level, which greatly improved the accuracy and robustness of quantitation. The developed method was investigated for linearity, accuracy, precision and lower limit of quantitation, all of which met the commonly accepted criteria for bioanalytical method validation. PMID:26307718
Validated enantiospecific LC method for determination of (R)-enantiomer impurity in (S)-efavirenz.
Seshachalam, U; Narasimha Rao, D V L; Chandrasekhar, K B
2008-02-01
A high-performance liquid chromatographic method was developed for separation of the enantiomers of efavirenz. The developed method was applied for the determination of (R)-enantiomer in (S)-efavirenz and satisfactory results were achieved. The base line separation with a resolution of more than 4.0 was achieved on Chiralcel OD (250 mm x 4.6 mm, 10 microm) column containing tris-(3,5-dimethylphenylcarbomate) as stationary phase. The mobile phase consists of n-hexane: isopropyl alcohol (80:20 v/v) with 0.1% (v/v) of formic acid as additive. The flow rate was kept at 1.0 ml/min and the UV detection was monitored at 254 nm. The (R)-enantiomer was found linear over the range of 0.1 microg/ml--6 microg/ml. The limit of detection (LOD) was 0.03 microg/ml and the limit of quantification (LOQ) was 0.1 microg/ml (n=3. The precision of (R)-enantiomer at LOQ level was evaluated through six replicate injections and the RSD of the peak response was achieved as 1.34%. The results demonstrated that the developed LC method was simple, precise, robust and applicable for the purity determination of efavirenz.
Bohm, Detlef A; Stachel, Carolin S; Gowik, Petra
2012-07-01
The presented multi-method was developed for the confirmation of 37 antibiotic substances from the six antibiotic groups: macrolides, lincosamides, quinolones, tetracyclines, pleuromutilines and diamino-pyrimidine derivatives. All substances were analysed simultaneously in a single analytical run with the same procedure, including an extraction with buffer, a clean-up by solid-phase extraction, and the measurement by liquid chromatography tandem mass spectrometry in ESI+ mode. The method was validated on the basis of an in-house validation concept with factorial design by combination of seven factors to check the robustness in a concentration range of 5-50 μg kg(-1). The honeys used were of different types with regard to colour and origin. The values calculated for the validation parameters-decision limit CCα (range, 7.5-12.9 μg kg(-1)), detection capability CCβ (range, 9.4-19.9 μg kg(-1)), within-laboratory reproducibility RSD(wR) (<20% except for tulathromycin with 23.5% and tylvalosin with 21.4 %), repeatability RSD(r) (<20% except for tylvalosin with 21.1%), and recovery (range, 92-106%)-were acceptable and in agreement with the criteria of Commission Decision 2002/657/EC. The validation results showed that the method was applicable for the residue analysis of antibiotics in honey to substances with and without recommended concentrations, although some changes had been tested during validation to determine the robustness of the method.
Mei, Shenghui; Luo, Xuying; Li, Xingang; Li, Qian; Huo, Jiping; Yang, Li; Zhu, Leting; Feng, Weixing; Zhou, Jianxin; Shi, Guangzhi; Zhao, Zhigang
2016-12-01
Tigecycline (TGC) is an important antibiotic in treating various drug-resistant bacteria. The dosage regimen for cerebral intraventricular TGC is still unknown. The aim of the study was to develop and validate liquid chromatography-tandem mass spectrometry (LC-MS/MS) methods for the determination of TGC in human plasma and cerebrospinal fluid (CSF) to obtain an applicable regimen. The ion transitions under ESI positive model were performed at m/z 586.3 > 513.2 and m/z 595.3 > 514.3 for TGC and d9-TGC internal standard (IS). For plasma and CSF samples, the calibration curve of TGC was linear within the ranges 25-2000 and 250-100,000 ng/mL; the IS normalized matrix effect was within the ranges 96.46-101.06% and 101.13-103.58%, respectively, for all. TGC was stable under all tested conditions. The patient received 1 mg intraventricular and 49 mg intravenous administration of TGC. The AUC 0-12 in plasma and CSF calculated according to our noncompartment model were 4713 and 23,0238 h ng/mL, respectively. Given our findings cerebral intraventricular TGC may be a choice for clinicians to treat drug-resistant Gram-negative bacterial-induced meningitis and the safety and efficacy of this administration route warrants further study. Copyright © 2016 John Wiley & Sons, Ltd.
Moretti, Matteo; Andrello, Luisa; Visonà, Silvia; Vignali, Claudia; Groppi, Angelo; Freni, Francesca; Osculati, Antonio; Tajana, Luca; Morini, Luca
2018-04-15
The study aims the development and validation of a LC-MS/MS method for the identification and quantification of benzodiazepines and zolpidem in nails as alternative keratinized matrix to hair in long-term monitoring of anxiolytic and hypnotic drugs. Both fingernail and toenail samples (1-2 mm) were collected by clipping the excess overhang of the nail from volunteers and from postmortem cases. They were washed twice with organic solvents, dried under nitrogen stream, pulverized, immersed in a methanol solution (internal standard: diazepam-D5) and sonicated up to two hours. The solution was then direct injected in the LC-MS/MS system. Mass spectrometry was set in MRM mode, selecting two transitions for each substance. 32 analytes among benzodiazepines, metabolites and hypnotics were included in the list. The method fulfilled the internationally required criteria for validation. Limits of detection ranged from 0.03 pg/mg (zolpidem) to 13.1 pg/mg (bromazepam). 9 subjects under therapy were positive at 7 different benzodiazepines and/or metabolites (lorazepam, desalkylflurazepam, bromazepam, diazepam, alprazolam, lormetazepam and prazepam), while 5 molecules were measured in 4 postmortem cases (diazepam, desmethyldiazepam, delorazepam, 7-aminoclonazepam and zolpidem). In vitro experiments on eight authentic samples suggested that benzodiazepines in nails are influenced by the prolonged exposure to chlorinated water. Copyright © 2018 Elsevier B.V. All rights reserved.
McGuffey, James E.; Wei, Binnian; Bernert, John T.; Morrow, John C.; Xia, Baoyun; Wang, Lanqing; Blount, Benjamin C.
2014-01-01
Tobacco use is a major contributor to premature morbidity and mortality. The measurement of nicotine and its metabolites in urine is a valuable tool for evaluating nicotine exposure and for nicotine metabolic profiling—i.e., metabolite ratios. In addition, the minor tobacco alkaloids—anabasine and anatabine—can be useful for monitoring compliance in smoking cessation programs that use nicotine replacement therapy. Because of an increasing demand for the measurement of urinary nicotine metabolites, we developed a rapid, low-cost method that uses isotope dilution liquid chromatography-tandem mass spectrometry (LC-MS/MS) for simultaneously quantifying nicotine, six nicotine metabolites, and two minor tobacco alkaloids in smokers' urine. This method enzymatically hydrolyzes conjugated nicotine (primarily glucuronides) and its metabolites. We then use acetone pretreatment to precipitate matrix components (endogenous proteins, salts, phospholipids, and exogenous enzyme) that may interfere with LC-MS/MS analysis. Subsequently, analytes (nicotine, cotinine, hydroxycotinine, norcotinine, nornicotine, cotinine N-oxide, nicotine 1′-N-oxide, anatabine, and anabasine) are chromatographically resolved within a cycle time of 13.5 minutes. The optimized assay produces linear responses across the analyte concentrations typically found in urine collected from daily smokers. Because matrix ion suppression may influence accuracy, we include a discussion of conventions employed in this procedure to minimize matrix interferences. Simplicity, low cost, low maintenance combined with high mean metabolite recovery (76–99%), specificity, accuracy (0–10% bias) and reproducibility (2–9% C.V.) make this method ideal for large high through-put studies. PMID:25013964
Determination of Dextromethorphan in Oral Fluid by LC-MS-MS.
Amaratunga, Piyadarsha; Clothier, Morgan; Lorenz Lemberg, Bridget; Lemberg, Dave
2016-06-01
Dextromethorphan (DXM) is an antitussive drug found in commonly used nonprescription cold and cough medications. At low doses, DXM is a safe drug that does not produce adverse reactions. However, abuse of DXM has been reported among adolescents and young adults using the drug at higher doses. DXM is not a scheduled drug in the USA, and the primary reason for its abuse is the ease of availability. DXM is available to purchase in the form of over-the-counter cough medications, such as Robitussin(®) and Coricidin(®), or it can be purchased over the Internet in the form of a powder. In this research work, we developed an LC-MS-MS method that can quantify DXM and dextrorphan (DXO) in oral fluid in a high-throughput toxicology laboratory setting. The developed method was validated according to the Scientific Working Group for Forensic Toxicology guidelines. The linear dynamic range was 5-100 ng/mL with a lowest limit of quantitation (LLOQ) of 5.0 ng/mL for DXM and DXO. Overall, the results of the accuracy and the precision values were within the acceptance criteria for both drugs. In addition, selectivity, matrix effect and recovery were calculated for the LC-MS-MS method. Authentic samples (n = 59) were tested to evaluate the applicability of the method. Thirty samples were found to be positive for DXM and DXO and two samples were found to be positive for DXM only. © The Author 2016. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.
Song, Shiming; Zhang, Cuifang; Chen, Zhaojie; He, Fengmei; Wei, Jie; Tan, Huihua; Li, Xuesheng
2018-07-06
In this study, we developed an anion exchanger-disposable pipette extraction (DPX) method to detect the residual concentrations of eight neonicotinoid insecticides (dinotefuran, acetamiprid, clothianidin, thiacloprid, imidachloprid, imidaclothiz, nitenpyram, and thiamethoxam) and eight insect growth regulators (IGRs; triflumuron, cyromazine, buprofezin, methoxyfenozide, tebufenozide, chromafenozide, fenoxycarb, and RH 5849) in Chinese honey samples collected from different floral sources and different geographical regions using liquid chromatography tandem mass spectrometry (LC-MS/MS). QAE Sephadex A-25 was used as the anion exchanger in the DPX column for the purification and cleanup of honey samples. Analytes were eluted with a mixture of acetonitrile and 0.1 M HCl, and the elution was subjected to LC analysis. This method was thoroughly validated for its reproducibility, linearity, trueness, and recovery. Satisfactory recovery of pesticides was obtained ranging from 72% to 111% with intraday RSDs (n = 5) of 1%-10%. High linearity (R 2 ≥ 0.9987) was observed for all 16 pesticides. Limits of detection and quantification for all 16 compounds ranged from 0.3 to 3 μg/kg and from 1 to 10 μg/kg, respectively. Pesticide residues (9-113 μg/kg) were found in Chinese honey samples. The anion exchanger-DPX method was effective for removing sugars and retaining target analytes. Moreover, this method was highly reliable and sensitive for detecting neonicotinoids and IGRs in different floral sources of honey and will be applicable to matrixes with high sugar content. Copyright © 2018 Elsevier B.V. All rights reserved.
Sheng, Yanghao; Zhou, Boting
2017-05-26
Therapeutic drug monitoring (TDM) is one of the most important services of clinical laboratories. Two main techniques are commonly used: the immunoassay and chromatography method. We have developed a cost-effective system of two-dimensional liquid chromatography with ultraviolet detection (2D-LC-UV) for high-throughput determination of vancomycin in human plasma that combines the automation and low start-up costs of the immunoassay with the high selectivity and sensitivity of the liquid chromatography coupled with mass spectrometric detection without incurring their disadvantages, achieving high cost-effectiveness. This 2D-LC system offers a large volume injection to provide sufficient sensitivity and uses simulated gradient peak compression technology to control peak broadening and to improve peak shape. A middle column was added to reduce the analysis cycle time and make it suitable for high-throughput routine clinical assays. The analysis cycle time was 4min and the peak width was 0.8min. Compared with other chromatographic methods that have been developed, the analysis cycle time and peak width for vancomycin was reduced significantly. The lower limit of quantification was 0.20μg/mL for vancomycin, which is the same as certain LC-MS/MS methods that have been recently developed and validated. The method is rapid, automated, and low-cost and has high selectivity and sensitivity for the quantification of vancomycin in human plasma, thus making it well-suited for use in hospital clinical laboratories. Copyright © 2017 Elsevier B.V. All rights reserved.
Koesukwiwat, Urairat; Vaclavik, Lukas; Mastovska, Katerina
2018-05-08
According to the European Commission directive 2006/141/EC, haloxyfop residue levels should not exceed 0.003 mg/kg in ready-to-feed infant formula, and the residue definition includes sum of haloxyfop, its esters, salts, and conjugates expressed as haloxyfop. A simple method for total haloxyfop analysis in infant formula and related ingredient matrices was developed and validated using liquid chromatography-tandem mass spectrometry (LC-MS/MS). The sample preparation consisted of an alkaline hydrolysis with methanolic sodium hydroxide to release haloxyfop (parent acid) from its bound forms prior to the extraction with acetonitrile. A mixture of magnesium sulfate (MgSO 4 ) and sodium chloride (NaCl) (4:1, w/w) was added to the extract to induce phase separation and force the analyte into the upper acetonitrile-methanol layer and then a 1-mL aliquot was subsequently cleaned up by dispersive solid phase extraction with 150 mg of MgSO 4 and 50 mg of octadecyl (C 18 ) sorbent. The analytical procedure was developed and carefully optimized to enable low-level, total haloxyfop analysis in a variety of challenging matrices, including infant formulas and their important high-carbohydrate, high-protein, high-fat, and emulsifier ingredients. The final method was validated in two different laboratories by fortifying samples with haloxyfop and haloxyfop-methyl, which was used as a model compound simulating bound forms of the analyte. Mean recoveries of haloxyfop across all fortification levels and evaluated matrices ranged between 92.2 and 114% with repeatability, within-lab reproducibility, and reproducibility RSDs ≤ 14%. Based on the validation results, this method was capable to convert the haloxyfop ester into the parent acid in a wide range of sample types and to reliably identify and quantify total haloxyfop at the target 0.003 mg/kg level in infant formulas (both powdered and ready-to-feed liquid forms). Graphical abstract LC-MS/MS-based workflow for the determination of the total haloxyfop in infant formula and related ingredients.
Jiang, Jian; James, Christopher A; Wong, Philip
2016-09-05
A LC-MS/MS method has been developed and validated for the determination of glycine in human cerebrospinal fluid (CSF). The validated method used artificial cerebrospinal fluid as a surrogate matrix for calibration standards. The calibration curve range for the assay was 100-10,000ng/mL and (13)C2, (15)N-glycine was used as an internal standard (IS). Pre-validation experiments were performed to demonstrate parallelism with surrogate matrix and standard addition methods. The mean endogenous glycine concentration in a pooled human CSF determined on three days by using artificial CSF as a surrogate matrix and the method of standard addition was found to be 748±30.6 and 768±18.1ng/mL, respectively. A percentage difference of -2.6% indicated that artificial CSF could be used as a surrogate calibration matrix for the determination of glycine in human CSF. Quality control (QC) samples, except the lower limit of quantitation (LLOQ) QC and low QC samples, were prepared by spiking glycine into aliquots of pooled human CSF sample. The low QC sample was prepared from a separate pooled human CSF sample containing low endogenous glycine concentrations, while the LLOQ QC sample was prepared in artificial CSF. Standard addition was used extensively to evaluate matrix effects during validation. The validated method was used to determine the endogenous glycine concentrations in human CSF samples. Incurred sample reanalysis demonstrated reproducibility of the method. Copyright © 2016 Elsevier B.V. All rights reserved.
Holzhütter, H G; Genschow, E; Diener, W; Schlede, E
2003-05-01
The acute toxic class (ATC) methods were developed for determining LD(50)/LC(50) estimates of chemical substances with significantly fewer animals than needed when applying conventional LD(50)/LC(50) tests. The ATC methods are sequential stepwise procedures with fixed starting doses/concentrations and a maximum of six animals used per dose/concentration. The numbers of dead/moribund animals determine whether further testing is necessary or whether the test is terminated. In recent years we have developed classification procedures for the oral, dermal and inhalation routes of administration by using biometric methods. The biometric approach assumes a probit model for the mortality probability of a single animal and assigns the chemical to that toxicity class for which the best concordance is achieved between the statistically expected and the observed numbers of dead/moribund animals at the various steps of the test procedure. In previous publications we have demonstrated the validity of the biometric ATC methods on the basis of data obtained for the oral ATC method in two-animal ring studies with 15 participants from six countries. Although the test procedures and biometric evaluations for the dermal and inhalation ATC methods have already been published, there was a need for an adaptation of the classification schemes to the starting doses/concentrations of the Globally Harmonized Classification System (GHS) recently adopted by the Organization for Economic Co-operation and Development (OECD). Here we present the biometric evaluation of the dermal and inhalation ATC methods for the starting doses/concentrations of the GHS and of some other international classification systems still in use. We have developed new test procedures and decision rules for the dermal and inhalation ATC methods, which require significantly fewer animals to provide predictions of toxicity classes, that are equally good or even better than those achieved by using the conventional LD(50)/LC(50) methods. In order to cope with rather narrow dose/concentration classes of the GHS we have, as in our previous publications, combined the outcome of all results that can be obtained during testing for the allocation to one of the defined toxicity classes of the GHS. Our results strongly recommend the deletion of the dermal LD(50) and the inhalation LC(50) test as regulatory tests and the adoption of the dermal and inhalation ATC methods as internationally accepted alternatives.
Jimmerson, Leah C.; Zheng, Jia-Hua; Bushman, Lane R.; MacBrayne, Christine E.; Anderson, Peter L.; Kiser, Jennifer J.
2014-01-01
Efficient, inexpensive and sensitive assays for the measurement of drugs are of interest for pharmacokinetic and pharmacodynamics (PK-PD) analysis. Dried blood spots (DBS) are a unique bioanaltyical matrix with the potential to fulfill this interest for the measurement of numerous analytes. Here we describe the development and validation of a reversed-phase high performance liquid chromatographic (LC), tandem mass spectrometry (MS/MS) assay for the determination of ribavirin (RBV) in DBS. A 3mm punch from spotted and dried whole blood was extracted in methanol utilizing isotopically labeled internal standard for LC-MS/MS analysis. Validation was performed over a range of 0.05 μg/mL to 10.0 μg/mL and the method was shown to be precise (coefficient of variation ≤ 15%) and accurate (within ±15% of control). These acceptance criteria were met for hematocrit ranges of 20-54%, for center versus edge punches and for spot volumes from 10-60 μL. RBV was stable for up to 140 days at room temperature and −20°C as well as for three freeze/thaw cycles. Correlation of RBV in DBS versus in plasma yielded r2 ≥ 0.98 demonstrating that DBS can be used as an alternative to plasma for PK-PD studies in human subjects. PMID:24291608
Stoll, Dwight R; Sajulga, Ray W; Voigt, Bryan N; Larson, Eli J; Jeong, Lena N; Rutan, Sarah C
2017-11-10
An important research direction in the continued development of two-dimensional liquid chromatography (2D-LC) is to improve the detection sensitivity of the method. This is especially important in applications where injection of large volumes of effluent from the first dimension ( 1 D) column into the second dimension ( 2 D) column leads to severe 2 D peak broadening and peak shape distortion. For example, this is common when coupling two reversed-phase columns and the organic solvent content of the 1 D mobile phase overwhelms the 2 D column with each injection of 1 D effluent, leading to low resolution in the second dimension. In a previous study we validated a simulation approach based on the Craig distribution model and adapted from the work of Czok and Guiochon [1] that enabled accurate simulation of simple isocratic and gradient separations with very small injection volumes, and isocratic separations with mismatched injection and mobile phase solvents [2]. In the present study we have extended this simulation approach to simulate separations relevant to 2D-LC. Specifically, we have focused on simulating 2 D separations where gradient elution conditions are used, there is mismatch between the sample solvent and the starting point in the gradient elution program, injection volumes approach or even exceed the dead volume of the 2 D column, and the extent of sample loop filling is varied. To validate this simulation we have compared results from simulations and experiments for 101 different conditions, including variation in injection volume (0.4-80μL), loop filling level (25-100%), and degree of mismatch between sample organic solvent and the starting point in the gradient elution program (-20 to +20% ACN). We find that that the simulation is accurate enough (median errors in retention time and peak width of -1.0 and -4.9%, without corrections for extra-column dispersion) to be useful in guiding optimization of 2D-LC separations. However, this requires that real injection profiles obtained from 2D-LC interface valves are used to simulate the introduction of samples into the 2 D column. These profiles are highly asymmetric - simulation using simple rectangular pulses leads to peak widths that are far too narrow under many conditions. We believe the simulation approach developed here will be useful for addressing practical questions in the development of 2D-LC methods. Copyright © 2017 Elsevier B.V. All rights reserved.
Codevilla, Cristiane Franco; Lemos, Alice Machado; Delgado, Leila Schreiner; Rolim, Clarice Madalena Bueno; Adams, Andréa Inês Horn; Bergold, Ana Maria
2011-08-01
A stability-indicating liquid chromatographic method has been developed for the quantitative determination of lodenafil carbonate in tablets. The method employs a Synergi Fusion C18 column (250 × 4.6 mm, i.d., 4 μm particle size), with mobile phase consisting of a mixture of methanol-acetic acid 0.1% pH 4.0 (65:35, v/v) and UV detection at 290 nm, using a photodiode array detector. A linear response (r = 0.9999) was observed in the range of 10-80 μg/mL. The method showed good recoveries (average 100.3%) and also intra and inter-day precision (RSD < 2.0%). Validation parameters as specificity and robustness were also determined. Specificity analysis showed that no impurities or degradation products were co-eluting with the lodenafil carbonate peak. The method was found to be stability-indicating and due to its simplicity and accuracy can be applied for routine quality control analysis of lodenafil carbonate in tablets.
The EIPeptiDi tool: enhancing peptide discovery in ICAT-based LC MS/MS experiments.
Cannataro, Mario; Cuda, Giovanni; Gaspari, Marco; Greco, Sergio; Tradigo, Giuseppe; Veltri, Pierangelo
2007-07-15
Isotope-coded affinity tags (ICAT) is a method for quantitative proteomics based on differential isotopic labeling, sample digestion and mass spectrometry (MS). The method allows the identification and relative quantification of proteins present in two samples and consists of the following phases. First, cysteine residues are either labeled using the ICAT Light or ICAT Heavy reagent (having identical chemical properties but different masses). Then, after whole sample digestion, the labeled peptides are captured selectively using the biotin tag contained in both ICAT reagents. Finally, the simplified peptide mixture is analyzed by nanoscale liquid chromatography-tandem mass spectrometry (LC-MS/MS). Nevertheless, the ICAT LC-MS/MS method still suffers from insufficient sample-to-sample reproducibility on peptide identification. In particular, the number and the type of peptides identified in different experiments can vary considerably and, thus, the statistical (comparative) analysis of sample sets is very challenging. Low information overlap at the peptide and, consequently, at the protein level, is very detrimental in situations where the number of samples to be analyzed is high. We designed a method for improving the data processing and peptide identification in sample sets subjected to ICAT labeling and LC-MS/MS analysis, based on cross validating MS/MS results. Such a method has been implemented in a tool, called EIPeptiDi, which boosts the ICAT data analysis software improving peptide identification throughout the input data set. Heavy/Light (H/L) pairs quantified but not identified by the MS/MS routine, are assigned to peptide sequences identified in other samples, by using similarity criteria based on chromatographic retention time and Heavy/Light mass attributes. EIPeptiDi significantly improves the number of identified peptides per sample, proving that the proposed method has a considerable impact on the protein identification process and, consequently, on the amount of potentially critical information in clinical studies. The EIPeptiDi tool is available at http://bioingegneria.unicz.it/~veltri/projects/eipeptidi/ with a demo data set. EIPeptiDi significantly increases the number of peptides identified and quantified in analyzed samples, thus reducing the number of unassigned H/L pairs and allowing a better comparative analysis of sample data sets.
Moore, Douglas E; Liu, Tina X; Miao, William G; Edwards, Alison; Elliss, Russell
2002-09-05
A reversed-phase liquid chromatographic method has been developed and validated for the determination of the polydimethylsiloxane (PDMS) component of Simethicone, which is used as an anti-foaming agent in pharmaceutical formulations. The method involves acidification to neutralise antacid components of the formulation, then a single extraction of the PDMS with dichloromethane. This is followed by separation with a reversed-phase column using an acetonitrile-chloroform solvent gradient, and quantification by an evaporative light scattering detector. An assay precision of 3% was achieved in intraday and interday determinations. No interference was found from the aluminium and magnesium hydroxide components of antacid formulations.
Zhang, Wenjie; Sun, Beicheng
2015-01-20
The risk of liver cancer (LC) is regarded as age dependent. However, the influence of age on its prognosis is controversial. The aim of our study was to compare the long-term survival of younger versus older patients with LC. In this retrospective study, we searched Surveillance, Epidemiology, and End-RESULTS (SEER) population-based data and identified 27,255 patients diagnosed with LC between 1988 and 2003. These patients were categorized into younger (45 years and under) and older age (over 45 years of age) groups. Five-year cancer specific survival data was obtained. Kaplan-Meier methods and multivariable Cox regression models were used to analyze long-term survival outcomes and risk factors. There were significant differences between groups with regards to pathologic grading, histologic type, stage, and tumor size (p < 0.001). The 5-year liver cancer specific survival (LCSS) rates in the younger and older age groups were 14.5% and 8.4%, respectively (p < 0.001 by univariate and multivariate analysis). A stratified analysis of age on cancer survival showed only localized and regional stages to be validated as independent predictors, but not for advanced stages. Compared to older patients, younger patients with LC have a higher LCSS after surgery, despite the poorer biological behavior of this carcinoma.
2010-01-01
Chrom LC –MS...Literature 3. DATES COVERED (From - To) 4. TITLE AND SUBTITLE A liquid chromatographic–mass spectrometric ( LC –MS) method for the analysis of the 5a...Journal of Chromatography B journa l homepage: www.e lsev ier .com/ locate /chromb A liquid chromatographic–mass spectrometric ( LC –MS) method for
Jiang, Juanjuan; Tian, Lei; Huang, Yiling; Yan, Yan; Li, Yishi
2016-08-01
A liquid chromatography-tandem mass spectrometry (LC-MS) method to quantify tolvaptan and its two main metabolites and applied to human study was first developed and validated as a measure of compliance in clinical research. Because of the structure similarity of tolvaptan and its multiple metabolites, the method was optimized to obtain a chromatographic and MS separation of the endogenous interference and isotope ions as well as high analysis throughput. Tolvaptan, its two main metabolites and the internal standard were extracted from human serum (0.1mL) using solid-phase extraction, separated on a Waters nova-pak C18 column (150×3.9mm, 5μm) using isocratic elution with a mobile phase composed of acetonitrile, water and formic acid (65:35:0.25, v/v/v). The total run-time was shortened to 3.5min. The mass transition ranges under positive electrospray ionisation that were monitored for quantitation included m/z 449-252 for tolvaptan, m/z 479-252 for metabolite DM-4103, m/z 481-252 for metabolite DM-4107 and m/z 463-266 for the internal standard (IS). The limit of quantification in plasma for all three analytes was 1ng/mL. The method was validated over a linear range from 1 to 500ng/mL for all three analytes with acceptable inter- and intra-assay precision and accuracy. The stability of the analytes was determined to be suitable for routine laboratory practices. The method was successfully applied to samples taken from research volunteers who ingested a 15mg tolvaptan tablet. Copyright © 2016. Published by Elsevier B.V.
Zawadzka, Iwona; Rodziewicz, Lech
2014-01-01
The European Union prohibits the use of chloramphenicol (CAP) as a veterinary drug in food-producing animals. Nevertheless, CAP have been detected in milk products (liquid milk and milk powder). Therefore, it is necessary to develop sensitive methods for determining CAP residues in milk powder. The aim of this study was to develop and validate a confirmatory method for determination of CAP in milk powder. Chloramphenicol was determined in milk powder using LC-ESI-MS/MS in negative mode. After fat removing milk powder sample was extracted/cleaned-up with a Chem Elut extraction cartridge. Separation was achieved on a Phenomenex Luna C-18 column with acetonitrile-water as a mobile phase. The mass spectrometer was operated in multiple reaction monitoring mode (MRM). Four transitions were monitored m/z 321→152, 321→194, 321→257 (CAP) and 326→157 (IS CAP-d5). Linearity, accuracy, precision, decision limit (CCa), detection capability (CCb) and ruggedness were determined for m/z 321→152. The mean relative recoveries (inter standard-corrected) of CAP from whole milk powder spiked at levels 0.1, 0.2, 0.3 and 0.6 mg/kg were in the range 95 - 103%. Relative standard deviation (RSD%) of recoveries at all spiked levels were less than 14%. RSDs within-laboratory reproducibility calculated at fortification of 0.3 mg/kg was less than 16%. CCa and CCb were below 0.1 mg/kg. The developed LC-MS/MS method allows the determination of CAP in milk powder. The method was validated according to the Commission Decision No. 2002/657/EC requirements. This method can be applied to determination CAP in whole and skim milk powder.
French, Deborah
2013-01-16
At our institution, serum testosterone in adult males is measured by immunoassay while female and pediatric specimens are sent to a reference laboratory for liquid chromatography-tandem mass spectrometry (LC-MS/MS) analysis due to low concentrations. As this is of significant cost, a testosterone LC-MS/MS assay was developed in-house. A 5500 QTRAP® using electrospray ionization and a Shimadzu Prominence with a C18 column were used. Gradient elution with formic acid, water and methanol:acetonitrile at 0.5 ml/min had a 7-min run-time. A liquid-liquid extraction with hexane:ethyl acetate was carried out on 200 μl of serum. Multiple reaction monitoring was employed. Sample preparation took ~80 min for 21 samples. Six calibrators were used (0-1263 ng/dl; concentration assigned by NIST SRM 971) with 3 quality controls (9, 168 and 532 ng/dl). The limits of detection and quantitation were 1 and 2 ng/dl respectively. Extraction recovery was ~90% and ion suppression ~5%. Within-run and total precision studies yielded <15% CV at the limit of quantitation and <7% CV through the rest of the linear range. Isobaric interferences were baseline separated from testosterone. Method comparisons between this assay, an immunoassay, and another LC-MS/MS assay were completed. An accurate and sensitive LC-MS/MS assay for total testosterone was developed. Bringing this assay in-house reduces turnaround time for clinicians and patients and saves our institution funds. Copyright © 2012 Elsevier B.V. All rights reserved.
Miller, Eleanor I; Wylie, Fiona M; Oliver, John S
2008-09-01
A liquid chromatography-tandem mass spectrometry method was developed and validated for the simultaneous identification and quantification of amphetamines, diazepam and its metabolites, cocaine and its metabolites, and opiates from hair using a single extraction method. As part of the method development, Gemini C18, Synergi Hydro RP, and Zorbax Stablebond-Phenyl LC columns were tested with three different mobile phases. Analyte recovery and limit of detection were evaluated for two different solid-phase extraction methods that used Bond Elut Certify and Clean Screen cartridges. Phosphate buffer (pH 5.0) was chosen as the optimum hair incubation medium because of the high stability of cocaine and 6-monoacetylmorphine using this method and faster sample preparation. The optimized method was fully validated. Linearity was established over the concentration range 0.2-10 ng/mg hair, and the correlation coefficients were all greater than 0.99. Total extraction recoveries were greater than 76%, detection limits were between 0.02 and 0.09 ng/mg, and the intra- and interday imprecisions were generally less than 20% in spiked hair. The intra- and interbatch imprecision of the method for a pooled authentic hair sample ranged from 1.4 to 23.4% relative standard deviation (RSD) and 8.3 to 25.4% RSD, respectively, for representative analytes from the different drug groups. The percent matrix effect ranged from 63.5 to 135.6%, with most analytes demonstrating ion suppression. Sixteen postmortem samples collected from suspected drug-related deaths were analyzed for the 17 drugs of abuse and metabolites included in the method. The method was sufficiently sensitive and specific for the analysis of drugs and metabolites in postmortem hair samples. There is scope for the inclusion of other target drugs and metabolites in the method.
Spanjer, Martien C; Rensen, Peter M; Scholten, Jos M
2008-04-01
Mycotoxin analysis is usually carried out by high performance liquid chromatography after immunoaffinity column cleanup or in enzyme-linked immunosorbent assay tests. These methods normally involve determination of single compounds only. EU legislation already exists for the aflatoxins, ochratoxin A and patulin in food, and legislation will come into force for deoxynivalenol, zearalenone and the fumonisins in 2007. To enforce the various legal limits, it would be preferable to determine all mycotoxins by routine analysis in different types of matrices in one single extract. This would also be advantageous for HACCP control purposes. For this reason, a multi-method was developed with which 33 mycotoxins in various products could be analysed simultaneously. The mycotoxins were extracted with an acetonitrile/water mixture, diluted with water and then directly injected into a LC-MS/MS system. The mycotoxins were separated by reversed-phase HPLC and detected using an electrospray ionisation interface (ESI) and tandem MS, using MRM in the positive ion mode, to increase specificity for quality control. The following mycotoxins could be analysed in a single 30-min run: Aflatoxins B1, B2, G1 and G2, ochratoxin A, deoxynivalenol, zearalenone, T-2 toxin, HT-2 toxin, alpha-zearalenol, alpha-zearalanol, beta-zearalanol, sterigmatocystin, cyclopiazonic acid, penicillic acid, fumonisins B1, B2 and B3, diacetoxyscirpenol, 3- and 15-acetyl-deoxynivalenol, zearalanone, ergotamin, ergocornin, ergocristin, alpha-ergocryptin, citrinin, roquefortin C, fusarenone X, nivalenol, mycophenolic acid, alternariol and alternariol monomethyl ether. The limit of quantification for the aflatoxins and ochratoxin A was 1.0 microg kg(-1) and for deoxynivalenol 50 microg kg(-1). The quantification limits for the other mycotoxins were in the range 10-200 microg kg(-1). The matrix effect and validation data are presented for between 13 and 24 mycotoxins in peanuts, pistachios, wheat, maize, cornflakes, raisins and figs. The method has been compared with the official EU method for the determination of aflatoxins in food and relevant FAPAS rounds. The multi-mycotoxin method has been proven by the detection of more than one mycotoxin in maize, buckwheat, figs and nuts. The LC-MS/MS technique has also been applied to baby food, which is subject to lower limits for aflatoxin B1 and ochratoxin A, ergot alkaloids in naturally contaminated rye and freeze-dried silage samples.
Lai, Kuan-Ming; Cheng, Yung-Yi; Tsai, Tung-Hu
2015-06-09
The herbal decoction process is generally inconvenient and unpleasant. To avoid using herbal medicine decoctions, various high-quality industrial and pharmaceutical herbal decoction products have been used in clinical applications for more than ten years in Taiwan. However, the consistency and standardization of the quality of these herbal medicines are goals that remain to be achieved. The aim of study was to develop a validated liquid chromatography-tandem electrospray ionization mass spectrometry (LC-MS/MS) method to determine the biomarkers astragaloside I, astragaloside IV, formononetin, cinnamic acid, paeoniflorin and gingerol in the herbal preparation known as Huangqi-Guizhi-Wuwu (HGW). To investigate the physical quality of HGW, methods such as scanning electron microscopy, light microscopy with Congo red and potassium iodine staining, solubility measurements, swelling power tests, and crude fiber analysis were used to identify additives in commercial pharmaceutical products. The optimal LC-MS/MS multiple reaction-monitoring system included a gradient program using 5 mM ammonium acetate buffer with 0.05% formic acid/methanol. The results demonstrate deviations in biomarker content across different brands. In addition to the herbal extract, starch and excipients in the pharmaceutical granule, and crushed crude herb powder was added to the pharmaceutical products to increase their herbal ingredient content. In conclusion, a rigorous examination should be performed to certify the quality of the herbal products.
NASA Astrophysics Data System (ADS)
Huan, Tao; Troyer, Dean A.; Li, Liang
2016-08-01
We report a method of metabolomic profiling of intact tissue based on molecular preservation by extraction and fixation (mPREF) and high-performance chemical isotope labeling (CIL) liquid chromatography mass spectrometry (LC-MS). mPREF extracts metabolites by aqueous methanol from tissue biopsies without altering tissue architecture and thus conventional histology can be performed on the same tissue. In a proof-of-principle study, we applied dansylation LC-MS to profile the amine/phenol submetabolome of prostate needle biopsies from 25 patient samples derived from 16 subjects. 2900 metabolites were consistently detected in more than 50% of the samples. This unprecedented coverage allowed us to identify significant metabolites for differentiating tumor and normal tissues. The panel of significant metabolites was refined using 36 additional samples from 18 subjects. Receiver Operating Characteristic (ROC) analysis showed area-under-the-curve (AUC) of 0.896 with sensitivity of 84.6% and specificity of 83.3% using 7 metabolites. A blind study of 24 additional validation samples gave a specificity of 90.9% at the same sensitivity of 84.6%. The mPREF extraction can be readily implemented into the existing clinical workflow. Our method of combining mPREF with CIL LC-MS offers a powerful and convenient means of performing histopathology and discovering or detecting metabolite biomarkers in the same tissue biopsy.
Magalhães, Luana; de Oliveira, Arthur Henrique Cavalcante; de Souza Vasconcellos, Raphael; Mariotini-Moura, Christiane; de Cássia Firmino, Rafaela; Fietto, Juliana Lopes Rangel; Cardoso, Carmen Lúcia
2016-01-01
Nucleoside triphosphate diphosphohydrolase (NTPDase) is an enzyme belonging to the apyrase family that participates in the hydrolysis of the nucleosides di- and triphosphate to the corresponding nucleoside monophosphate. This enzyme underlies the virulence of parasites such as Leishmania. Recently, an NTPDase from Leishmania infantum (LicNTPDase-2) was cloned and expressed and has been considered as a new drug target for the treatment of leishmaniasis. With the intent of developing label-free online screening methodologies, LicNTPDase-2 was covalently immobilized onto a fused silica capillary tube in the present study to create an immobilized capillary enzyme reactor (ICER) based on LicNTPDase-2 (LicNTPDase-2-ICER). To perform the activity assays, a multidimensional chromatographic method was developed employing the LicNTPDase-2-ICER in the first dimension, and an analytical Ascentis C8 column was used in the second dimension to provide analytical separation of the substrates and products. The validated LicNTPDase-2-ICER method provided the following kinetic parameters of the immobilized enzyme: KM of 2.2 and 1.8mmolL(-1) for the ADP and ATP substrates, respectively. Suramin (1mmolL(-1)) was also shown to inhibit 32.9% of the enzymatic activity. The developed method is applicable to kinetic studies and enables the recognition of the ligands. Furthermore, a comparison of the values of LicNTPDase-2-ICER with those obtained with an LC method using free enzyme in solution showed that LicNTPDase-2-ICER-LC/UV was an accurate and reproducible method that enabled automated measurements for the rapid screening of ligands. Copyright © 2015 Elsevier B.V. All rights reserved.
Hamamura, Kensuke; Yanagida, Mitsuaki; Ishikawa, Hitoshi; Banzai, Michio; Yoshitake, Hiroshi; Nonaka, Daisuke; Tanaka, Kenji; Sakuraba, Mayumi; Miyakuni, Yasuka; Takamori, Kenji; Nojima, Michio; Yoshida, Koyo; Fujiwara, Hiroshi; Takeda, Satoru; Araki, Yoshihiko
2018-03-01
Purpose We previously attempted to develop quantitative enzyme-linked immunosorbent assay (ELISA) systems for the PDA039/044/071 peptides, potential serum disease biomarkers (DBMs) of pregnancy-induced hypertension (PIH), primarily identified by a peptidomic approach (BLOTCHIP®-mass spectrometry (MS)). However, our methodology did not extend to PDA071 (cysteinyl α2-HS-glycoprotein 341-367 ), due to difficulty to produce a specific antibody against the peptide. The aim of the present study was to establish an alternative PDA071 quantitation system using liquid chromatography-multiple reaction monitoring (LC-MRM)/MS, to explore the potential utility of PDA071 as a DBM for PIH. Methods We tested heat/acid denaturation methods in efforts to purify serum PDA071 and developed an LC-MRM/MS method allowing for specific quantitation thereof. We measured serum PDA071 concentrations, and these results were validated including by three-dimensional (3D) plotting against PDA039 (kininogen-1 439-456 )/044 (kininogen-1 438-456 ) concentrations, followed by discriminant analysis. Results PDA071 was successfully extracted from serum using a heat denaturation method. Optimum conditions for quantitation via LC-MRM/MS were developed; the assayed serum PDA071 correlated well with the BLOTCHIP® assay values. Although the PDA071 alone did not significantly differ between patients and controls, 3D plotting of PDA039/044/071 peptide concentrations and construction of a Jackknife classification matrix were satisfactory in terms of PIH diagnostic precision. Conclusions Combination analysis using both PDA071 and PDA039/044 concentrations allowed PIH diagnostic accuracy to be attained, and our method will be valuable in future pathophysiological studies of hypertensive disorders of pregnancy.
Ho, Emmie N M; Kwok, W H; Wong, April S Y; Wan, Terence S M
2012-01-13
Quaternary ammonium drugs (QADs) are anticholinergic agents some of which are known to have been abused or misused in equine sports. A recent review of literature shows that the screening methods reported thus far for QADs mainly cover singly-charged QADs. Doubly-charged QADs are extremely polar substances which are difficult to be extracted and poorly retained on reversed-phase columns. It would be ideal if a comprehensive method can be developed which can detect both singly- and doubly-charged QADs. This paper describes an efficient liquid chromatography/tandem mass spectrometry (LC/MS/MS) method for the simultaneous detection and confirmation of 38 singly- and doubly-charged QADs at sub-parts-per-billion (ppb) to low-ppb levels in equine urine after solid-phase extraction. Quaternary ammonium drugs were extracted from equine urine by solid-phase extraction (SPE) using an ISOLUTE(®) CBA SPE column and analysed by LC/MS/MS in the positive electrospray ionisation mode. Separation of the 38 QADs was achieved on a polar group embedded C18 LC column with a mixture of aqueous ammonium formate (pH 3.0, 10 mM) and acetonitrile as the mobile phase. Detection and confirmation of the 38 QADs at sub-ppb to low-ppb levels in equine urine could be achieved within 16 min using selected reaction monitoring (SRM). Matrix interference of the target transitions at the expected retention times was not observed. Other method validation data, including precision and recovery, were acceptable. The method was successfully applied to the analyses of drug-administration samples. Copyright © 2011 Elsevier B.V. All rights reserved.
Workshop Report: Crystal City VI-Bioanalytical Method Validation for Biomarkers.
Arnold, Mark E; Booth, Brian; King, Lindsay; Ray, Chad
2016-11-01
With the growing focus on translational research and the use of biomarkers to drive drug development and approvals, biomarkers have become a significant area of research within the pharmaceutical industry. However, until the US Food and Drug Administration's (FDA) 2013 draft guidance on bioanalytical method validation included consideration of biomarker assays using LC-MS and LBA, those assays were created, validated, and used without standards of performance. This lack of expectations resulted in the FDA receiving data from assays of varying quality in support of efficacy and safety claims. The AAPS Crystal City VI (CC VI) Workshop in 2015 was held as the first forum for industry-FDA discussion around the general issues of biomarker measurements (e.g., endogenous levels) and specific technology strengths and weaknesses. The 2-day workshop served to develop a common understanding among the industrial scientific community of the issues around biomarkers, informed the FDA of the current state of the science, and will serve as a basis for further dialogue as experience with biomarkers expands with both groups.
Yi, Deliang; Wang, Zhihua; Yi, Longzhi
2015-04-01
A selective and sensitive liquid chromatography-mass spectrometry (MS) method was developed and validated for the determination of karanjin in rat plasma. The target analyte, together with the internal standard (warfarin), was extracted from rat plasma by liquid-liquid extraction with ethyl acetate. Chromatographic separation was performed on a ZORBAX SB-C18 column using a mixture of acetonitrile and 0.1% aqueous formic acid as the mobile phase with linear gradient elution. MS detection was performed on a single quadrupole MS by selected ion monitoring mode via a positive electrospray ionization source. The assay exhibited a linear dynamic range of 2.50-3,000 ng/mL for karanjin. The intra- and inter-day precision was <10.8%, and the intra- and inter-day accuracy was <9.2%. The validated method has been applied to the preclinical pharmacokinetic studies of karanjin following oral administration of 5, 10 and 20 mg/kg karanjin to rats. © The Author 2014. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.
Bock, C; Stachel, C; Gowik, P
2007-03-14
A method for the detection and determination of nitrofuran derivatives in egg by liquid chromatography-tandem mass spectrometry (LC-MS/MS) was validated with the software InterVal and can be applied for the confirmation of nitrofuran metabolites in fresh or lyophilised eggs. The validation study comprises variations in operator, storage condition, breeding, equipment and duration of sample preparation. A comprehensive overview of the robustness of the method is obtained by analysing eight samples at six concentration levels. First results of short- and medium-term investigations for stability of analytes in solution show that standard solutions of nitrofuran metabolites are stable for at least 1 year when stored at +4 degrees C in the dark. The decision limit CCalpha expressed for the underivatised metabolite is 0.05 microg kg(-1) for 3-amino-5-methyl-morpholino-2-oxazolidinone, 0.03 microg kg(-1) for 3-amino-2-oxazolidinone, 0.20 microg kg(-1) for semicarbazide and 0.22 microg kg(-1) for 1-amino-hydantoin.
Dziadosz, Marek
2017-01-01
LC-MS using electrospray ionisation (negative ion mode) and low-energy collision-induced dissociation tandem mass spectrometric (CID-MS/MS) analysis, together with the multiple analyte adduct formation with the components of the mobile phase, were applied to analyse valproic acid in human serum with LC-MS 3 . The CID-fragmentation of the precursor analyte adduct [M+2CH 3 COONa-H] - was applied in the method validation (307.1/225.1/143.0). Chromatographic separation was performed with a Luna 5μm C18 (2) 100A, 150mm×2mm column and the elution with a mobile phase consisting of A (H 2 O/methanol=95/5, v/v) and B (H 2 O/methanol=3/97, v/v), both with 10mM ammonium acetate and 0.1% acetic acid. A binary flow pumping mode with a total flow rate of 0.400mL/min was used. The calculated limit of detection/quantification of the method calibrated in the range of 10-200μg/mL was 0.31/1.0μg/mL. The sample preparation based on protein precipitation with 1mL of H 2 O/methanol solution (3/97, v/v) with 10mM sodium acetate and 100mM acetic acid. On the basis of the experiments performed could be demonstrated, that multiple analyte adduct formation can be applied to generate MS 3 quantitation of analytes with problematic fragmentation. The presented new strategy makes the analysis of small drugs, which do not produce any stable product ions at all, on the basis of LC-MS 3 possible. Copyright © 2016 Elsevier B.V. All rights reserved.
Bortoluzzi, Eduardo A.; Niu, Li-na; Palani, Chithra D.; El-Awady, Ahmed R.; Hammond, Barry D.; Pei, Dan-dan; Tian, Fu-cong; Cutler, Christopher W.; Pashley, David H.; Tay, Franklin R.
2016-01-01
Objectives In pulpal revascularization, a protective material is placed coronal to the blood clot to prevent recontamination and to facilitate osteogenic differentiation of mesenchynal stem cells to produce new dental tissues. Although mineral trioxide aggregate (MTA) has been the material of choice for clot protection, it is easily displaced into the clot during condensation. The present study evaluated the effects of recently-introduced calcium silicate cements (Biodentine and TheraCal LC) on the viability and osteogenic differentiation of human dental pulp stem cells (hDPSCs) by comparing with MTA Angelus. Methods Cell viability was assessed using XTT assay and flow cytometry. The osteogenic potential of hDPSCs exposed to calcium silicate cements was examined using qRT-PCR for osteogeic gene expressions, alkaline phosphatase enzyme activity, Alizarin red S staining and transmission electron microscopy of extracellular calcium deposits. Parametric statistical methods were employed for analyses of significant difference among groups, with α=0.05. Results The cytotoxic effects of Biodentine and TheraCal LC on hDPSCs were time- and concentration-dependent. Osteogenic differentiation of hDPSCs was enhanced after exposure to Biodentine that was depleted of its cytotoxic components. This effect was less readily observed in hDPSCs exposed to TheraCal LC, although both cements supported extracelluar mineralization better than the positive control (zinc oxide-eugenol–based cement). Significance A favorable tissue response is anticipated to occur with the use of Biodentine as a blood clot-protecting material for pulpal revascularizaiton. Further investigations with the use of in vivo animal models are required to validate the potential adverse biological effects of TheraCal LC on hDPSCs. PMID:26494267
Székely, Gy; Henriques, B; Gil, M; Ramos, A; Alvarez, C
2012-11-01
The present study reports on a liquid chromatography-tandem mass spectrometry (LC-MS/MS) method development strategy supported by design of experiments (DoE) for the trace analysis of 4-dimethylaminopyridine (DMAP). The conventional approaches for development of LC-MS/MS methods are usually via trial and error, varying intentionally the experimental factors which is time consuming and interactions between experimental factors are not considered. The LC factors chosen for the DoE study include flow (F), gradient (G) and injection volume (V(inj)) while cone voltage (E(con)) and collision energy (E(col)) were chosen as MS parameters. All of the five factors were studied simultaneously. The method was optimized with respect to four responses: separation of peaks (Sep), peak area (A(peak)), length of the analysis (T) and the signal to noise ratio (S/N). A quadratic model, namely central composite face (CCF) featuring 29 runs was used instead of a less powerful linear model since the increase in the number of injections was insignificant. In order to determine the robustness of the method a new set of DoE experiments was carried out applying robustness around the optimal conditions was evaluated applying a fractional factorial of resolution III with 11 runs, wherein additional factors - such as column temperature and quadrupole resolution - were considered. The method utilizes a Phenomenex Gemini NX C-18 HPLC analytical column with electrospray ionization and a triple quadrupole mass detector in multiple reaction monitoring (MRM) mode, resulting in short analyses with a 10min runtime. Drawbacks of derivatization, namely incomplete reaction and time consuming sample preparation, have been avoided and the change from SIM to MRM mode resulted in increased sensitivity and lower LOQ. The DoE method development strategy led to a method allowing the trace analysis of DMAP at 0.5 ng/ml absolute concentration which corresponds to a 0.1 ppm limit of quantification in 5mg/ml mometasone furoate glucocorticoid. The obtained method was validated in a linear range of 0.1-10 ppm and presented a %RSD of 0.02% for system precision. Regarding DMAP recovery in mometasone furoate, spiked samples produced %recoveries between 83 and 113% in the range of 0.1-2 ppm. Copyright © 2012 Elsevier B.V. All rights reserved.
Gandhi, Adarsh; Matta, Murali; Garimella, Narayana; Zere, Tesfalem; Weaver, James
2018-06-01
Extensive use and misuse of antibiotics over the past 50 years has contributed to the emergence and spread of antibiotic-resistant bacterial strains, rendering them as a global health concern. To address this issue, a dynamic in vitro hollow-fiber system, which mimics the in vivo environment more closely than the static model, was used to study the emergence of bacterial resistance of Escherichia coli against fosfomycin (FOS). To aid in this endeavor we developed and validated a liquid chromatography-tandem mass spectrometry (LC-MS/MS) assay for quantitative analysis of FOS in lysogeny broth. FOS was resolved on a Kinetex HILIC (2.1 × 50 mm, 2.6 μm) column with 2 mm ammonium acetate (pH 4.76) and acetonitrile as mobile phase within 3 min. Multiple reaction monitoring was used to acquire data on a triple quadrupole mass spectrometer. The assay was linear from 1 to 1000 μg/mL. Inter- and intra-assay precision and accuracy were <15% and between ±85 and 115% respectively. No significant matrix effect was observed when corrected with the internal standard. FOS was stable for up to 24 h at room temperature, up to three freeze-thaw cycles and up to 24 h when stored at 4°C in the autosampler. In vitro experimental data were similar to the simulated plasma pharmacokinetic data, further confirming the appropriateness of the experimental design to quantitate antibiotics and study occurrence of antimicrobial resistance in real time. The validated LC-MS/MS assays for quantitative determination of FOS in lysogeny broth will help antimicrobial drug resistance studies. Published 2018. This article is a U.S. Government work and is in the public domain in the USA.
NASA Astrophysics Data System (ADS)
Raju, Kanumuri Siva Rama; Taneja, Isha; Rashid, Mamunur; Sonkar, Ashish Kumar; Wahajuddin, Muhammad; Singh, Sheelendra Pratap
2016-03-01
A simple, sensitive and high throughput LC-MS/MS method was developed and validated for quantification of fipronil, fipronil sulfone and fipronil desulfinyl in rat and human dried blood spots (DBS). DBS samples were prepared by spiking 10 μl blood on DMPK-C cards followed by drying at room temperature. The whole blood spots were then punched from the card and extracted using acetonitrile. The total chromatographic run time of the method was only 2 min. The lower limit of quantification of the method was 0.1 ng/ml for all the analytes. The method was successfully applied to determine fipronil desulfinyl in DBS samples obtained from its toxicokinetic study in rats following intravenous dose (1 mg/kg). In conclusion, the proposed DBS methodology has significant potential in toxicokinetics and biomonitoring studies of environmental toxicants. This microvolume DBS technique will be an ideal tool for biomonitoring studies, particularly in paediatric population. Small volume requirements, minimally invasive blood sampling method, easier storage and shipping procedure make DBS a suitable technique for such studies. Further, DBS technique contributes towards the principles of 3Rs resulting in significant reduction in the number of rodents used and refinement in sample collection for toxicokinetic studies.
NASA Astrophysics Data System (ADS)
Hu, Yong; Wu, Hai-Long; Yin, Xiao-Li; Gu, Hui-Wen; Xiao, Rong; Wang, Li; Fang, Huan; Yu, Ru-Qin
2017-03-01
A rapid interference-free spectrofluorometric method combined with the excitation-emission matrix fluorescence and the second-order calibration methods based on the alternating penalty trilinear decomposition (APTLD) and the self-weighted alternating trilinear decomposition (SWATLD) algorithms, was proposed for the simultaneous determination of nephrotoxic aristolochic acid I (AA-I) and aristololactam I (AL-I) in five Chinese herbal medicines. The method was based on a chemical derivatization that converts the non-fluorescent AA-I to high-fluorescent AL-I, achieving a high sensitive and simultaneous quantification of the analytes. The variables of the derivatization reaction that conducted by using zinc powder in acetose methanol aqueous solution, were studied and optimized for best quantification results of AA-I and AL-I. The satisfactory results of AA-I and AL-I for the spiked recovery assay were achieved with average recoveries in the range of 100.4-103.8% and RMSEPs < 0.78 ng mL- 1, which validate the accuracy and reliability of the proposed method. The contents of AA-I and AL-I in five herbal medicines obtained from the proposed method were also in good accordance with those of the validated LC-MS/MS method. In light of high sensitive fluorescence detection, the limits of detection (LODs) of AA-I and AL-I for the proposed method compare favorably with that of the LC-MS/MS method, with the LODs < 0.35 and 0.29 ng mL- 1, respectively. The proposed strategy based on the APTLD and SWATLD algorithms by virtue of the "second-order advantage", can be considered as an attractive and green alternative for the quantification of AA-I and AL-I in complex herbal medicine matrices without any prior separations and clear-up processes.
Review of Software Tools for Design and Analysis of Large scale MRM Proteomic Datasets
Colangelo, Christopher M.; Chung, Lisa; Bruce, Can; Cheung, Kei-Hoi
2013-01-01
Selective or Multiple Reaction monitoring (SRM/MRM) is a liquid-chromatography (LC)/tandem-mass spectrometry (MS/MS) method that enables the quantitation of specific proteins in a sample by analyzing precursor ions and the fragment ions of their selected tryptic peptides. Instrumentation software has advanced to the point that thousands of transitions (pairs of primary and secondary m/z values) can be measured in a triple quadrupole instrument coupled to an LC, by a well-designed scheduling and selection of m/z windows. The design of a good MRM assay relies on the availability of peptide spectra from previous discovery-phase LC-MS/MS studies. The tedious aspect of manually developing and processing MRM assays involving thousands of transitions has spurred to development of software tools to automate this process. Software packages have been developed for project management, assay development, assay validation, data export, peak integration, quality assessment, and biostatistical analysis. No single tool provides a complete end-to-end solution, thus this article reviews the current state and discusses future directions of these software tools in order to enable researchers to combine these tools for a comprehensive targeted proteomics workflow. PMID:23702368
Valkenborg, Dirk; Baggerman, Geert; Vanaerschot, Manu; Witters, Erwin; Dujardin, Jean-Claude; Burzykowski, Tomasz; Berg, Maya
2013-01-01
Abstract Combining liquid chromatography-mass spectrometry (LC-MS)-based metabolomics experiments that were collected over a long period of time remains problematic due to systematic variability between LC-MS measurements. Until now, most normalization methods for LC-MS data are model-driven, based on internal standards or intermediate quality control runs, where an external model is extrapolated to the dataset of interest. In the first part of this article, we evaluate several existing data-driven normalization approaches on LC-MS metabolomics experiments, which do not require the use of internal standards. According to variability measures, each normalization method performs relatively well, showing that the use of any normalization method will greatly improve data-analysis originating from multiple experimental runs. In the second part, we apply cyclic-Loess normalization to a Leishmania sample. This normalization method allows the removal of systematic variability between two measurement blocks over time and maintains the differential metabolites. In conclusion, normalization allows for pooling datasets from different measurement blocks over time and increases the statistical power of the analysis, hence paving the way to increase the scale of LC-MS metabolomics experiments. From our investigation, we recommend data-driven normalization methods over model-driven normalization methods, if only a few internal standards were used. Moreover, data-driven normalization methods are the best option to normalize datasets from untargeted LC-MS experiments. PMID:23808607
Development of HPLC-ELSD method for determination of maltodextrin in raw milk.
Moraes, Flávia Santana; da Costa, Marion Pereira; de Melo Silva, Vitor Luiz; de Barros Pinto Moreira, Rodrigo Vilela; de Barros, Raphael Ferreira; Mársico, Eliane Teixeira; Conte-Junior, Carlos Adam; de Oliveira Silva, Adriana Cristina
2017-02-15
An analytical method was developed and validated for the determination of maltodextrin in raw milk, using high-performance liquid chromatography with evaporative light scattering detection. Maltodextrin content was evaluated in adulterated raw milk using a Supelcosil LC-NH2 (25cm×4.6mm) column and isocratic elution (68% of acetonitrile). Validation parameters exhibited adequate linearity, with relative standard deviation values between 0.74 and 2.16% (n=10) for repeatability and 0.11-19.39% (n=5) for intermediate precision. Limits of detection and quantification were 0.78 and 1.56mg.mL(-1), respectively, and recovery rates were between 91 and 93% for three levels. The application of this method shows that maltodextrin concentrations found in adulterated samples are lower than expected, which may be related to the quality of the commercial maltodextrin used. The method proposed proved to be simple and appropriate for the determination of maltodextrin in raw milk, with detection down to adulteration levels of 1%. Copyright © 2016 Elsevier Ltd. All rights reserved.
Zeric Stosic, Marina Z; Jaksic, Sandra M; Stojanov, Igor M; Apic, Jelena B; Ratajac, Radomir D
2016-11-01
High-performance liquid chromatography (HPLC) method with diode array detection (DAD) were optimized and validated for separation and determination of tetramethrin in an antiparasitic human shampoo. In order to optimize separation conditions, two different columns, different column oven temperatures, as well as mobile phase composition and ratio, were tested. Best separation was achieved on the Supelcosil TM LC-18- DB column (4.6 x 250 mm), particle size 5 jim, with mobile phase methanol : water (78 : 22, v/v) at a flow rate of 0.8 mL/min and at temperature of 30⁰C. The detection wavelength of the detector was set at 220 nm. Under the optimum chromatographic conditions, standard calibration curve was measured with good linearity [r2 = 0.9997]. Accuracy of the method defined as a mean recovery of tetramethrin from shampoo matrix was 100.09%. The advantages of this method are that it can easily be used for the routine analysis of drug tetramethrin in pharmaceutical formulas and in all pharmaceutical researches involving tetramethrin.
Shu, Irene; Wang, Ping
2013-06-01
Concentrations of nicotine and its metabolites in blood are indicative of patients' current tobacco exposure, and their quantifications have been clinically applied to multiple assessments including demonstration of abstinence prior to heart-lung transplantation. For the purpose of transplant evaluation, the laboratory work up is extensive; thereby an assay with minimal sample volume is preferred. We developed and validated a rapid LC-MS/MS assay to simultaneously quantitate nicotine and its major metabolites, Cotinine and trans-3'-OH-cotinine (3-OH-Cot), in serum. 100μL of serum was spiked with deuterated internal standards and extracted by Oasis HLB solid phase extraction cartridge. Nicotine and metabolites in the reconstituted serum extract were separated by Agilent Eclipse XDB-C8 3.5μm 2.1mm×50mm HPLC column within 4.7min, and quantified by MS/MS with positive mode electrospray ionization and multiple reaction monitoring. Ion suppression was insignificant, and extraction efficiency was 79-110% at 50ng/mL for all compounds. Limit of detection was 1.0ng/mL for nicotine and 3-OH-Cot, and <0.5ng/mL for Cotinine. Linearity ranges for nicotine, cotinine and 3-OH-Cot were 2-100, 2-1000, and 5-1000ng/mL with recoveries of 86-115%. Within-day and twenty-day imprecision at nicotine/cotinine/3-OH-Cot levels of 22/150/90, 37/250/150, and 50/800/500ng/mL were all 1.1-6.5%. The reconstituted serum extracts were stable for at least 7 days stored in the HPLC autosampler at 5°C. Our method correlates well with alternative LC-MS/MS methods. We successfully developed and validated an LC-MS/MS assay to quantitate concentrations of nicotine and its metabolites in serum with minimal sample volume to assess tobacco exposure of heart-lung transplant patients. Copyright © 2013 Elsevier B.V. All rights reserved.
Dash, Alekha K; Sawhney, Angeli
2002-07-31
The objective of this study was to develop a simple and sensitive LC method for the determination of creatine and creatinine in various creatine supplement formulations. The chromatographic system comprised of a LC-600 pump, SCL-6B system controller, and SPD-6AV detector (Shimadzu, Japan). The mobile phase consisted of 0.045 M ammonium sulfate in water. The chromatographic separation was achieved at ambient temperature on a Betabasic C-18 column (250 x 4.6 mm, Keystone Sci.). The flow rate was maintained at 0.75 ml/min and effluents are monitored at 205 nm. 4-(2-Aminoethyl)benzene sulfonamide was used as an internal standard (IS). This method required less than 7 min of chromatographic time. The standard curves were linear over the concentration range of 1-100 microg/ml for creatine and 2-100 microg/ml for creatinine, respectively. The relative standard deviations (RSD) for the within-day and day-to-day precision for creatine were within 1.0-4.6 and 2.2-4.7%, respectively. The RSD for the accuracy of creatine assay was in the range of 2.4-4.7%. The RSD values for the within-day precision, day-to-day precision and accuracy for creatinine validation were 1.7-4.4, 2.3-5.4 and 2.4-4.8%, respectively. This method was used to determine: (i) the creatine concentration in various marketed products; (ii) saturated solubility of various creatine salts; and (iii) stability of creatine in aqueous solution. In conclusion, a simple and sensitive LC method with UV detection was developed for the simultaneous determination of creatine and creatinine in formulations. Di-creatine citrate salt showed a higher aqueous solubility (at 25 degrees C) as compared to creatine and creatine monohydrate. Some of the over-the-counter (OTC) products tested contained a very low level of creatine in contrast to their label claim. Substantial conversion of creatine into creatinine was noticed in liquid formulation.
Li, Tengfei; Cui, Zhimin; Wang, Yan; Yang, Wen; Li, Duo; Song, QinXin; Sun, Luning; Ding, Li
2018-03-20
As an orally active iron chelator, deferasirox forms its ion complexes in the prepared plasma samples and LC-MS mobile phase where ferric ion exists, and then comparing with the nominal concentration level, a lower detected concentration level of deferasirox would be obtained after LC-MS analysis, if no proper treatment was adopted. Meanwhile, the phenomenon would be observed that multiple repeat injections of the same deferasirox plasma sample in the same tube would show the lower and lower detected concentration levels of deferasirox, which caused by more and more ferric ions from the injection needle dissolved in the sample solution as multiple repeated injections. The addition of a proper concentration of EDTA in the mobile phase and the sample will competitively inhibit deferasirox from complexing with ferric ion, and prevent the decrease of deferasirox concentration. In this paper, an LC-MS/MS method was developed and validated for the determination of deferasirox in human plasma. To achieve the protein precipitation, the analytes were extracted from aliquots of 200 μL human plasma with acetonitrile. Chromatographic separation was performed on an ODS-C18 column with the mobile phase consisted of methanol and 0.1% formic acid containing 0.04 mM ethylenediamine tetraacetate dihydrate (EDTA) (80:20, v/v) at a flow rate of 0.5 mL/min. Deferasirox and the internal standard (IS, mifepristone) were detected using electrospray ionization in positive ion multiple reaction monitoring mode by monitoring the precursor-to-product ion transitions m/z 374.2 → 108.1 for deferasirox and m/z 430.1 → 372.2 for the IS. The method exhibited good linearity over the concentration range of 0.04-40 μg/mL for deferasirox. The method was successfully applied to a pharmacokinetic study in 10 Chinese healthy volunteers after oral administration of deferasirox. Copyright © 2018 Elsevier B.V. All rights reserved.