Sample records for validated plasma samples

  1. An integrated bioanalytical method development and validation approach: case studies.

    PubMed

    Xue, Y-J; Melo, Brian; Vallejo, Martha; Zhao, Yuwen; Tang, Lina; Chen, Yuan-Shek; Keller, Karin M

    2012-10-01

    We proposed an integrated bioanalytical method development and validation approach: (1) method screening based on analyte's physicochemical properties and metabolism information to determine the most appropriate extraction/analysis conditions; (2) preliminary stability evaluation using both quality control and incurred samples to establish sample collection, storage and processing conditions; (3) mock validation to examine method accuracy and precision and incurred sample reproducibility; and (4) method validation to confirm the results obtained during method development. This integrated approach was applied to the determination of compound I in rat plasma and compound II in rat and dog plasma. The effectiveness of the approach was demonstrated by the superior quality of three method validations: (1) a zero run failure rate; (2) >93% of quality control results within 10% of nominal values; and (3) 99% incurred sample within 9.2% of the original values. In addition, rat and dog plasma methods for compound II were successfully applied to analyze more than 900 plasma samples obtained from Investigational New Drug (IND) toxicology studies in rats and dogs with near perfect results: (1) a zero run failure rate; (2) excellent accuracy and precision for standards and quality controls; and (3) 98% incurred samples within 15% of the original values. Copyright © 2011 John Wiley & Sons, Ltd.

  2. MRM validation of targeted nonglycosylated peptides from N-glycoprotein biomarkers using direct trypsin digestion of undepleted human plasma.

    PubMed

    Lee, Ju Yeon; Kim, Jin Young; Cheon, Mi Hee; Park, Gun Wook; Ahn, Yeong Hee; Moon, Myeong Hee; Yoo, Jong Shin

    2014-02-26

    A rapid, simple, and reproducible MRM-based validation method for serological glycoprotein biomarkers in clinical use was developed by targeting the nonglycosylated tryptic peptides adjacent to N-glycosylation sites. Since changes in protein glycosylation are known to be associated with a variety of diseases, glycoproteins have been major targets in biomarker discovery. We previously found that nonglycosylated tryptic peptides adjacent to N-glycosylation sites differed in concentration between normal and hepatocellular carcinoma (HCC) plasma due to differences in steric hindrance of the glycan moiety in N-glycoproteins to tryptic digestion (Lee et al., 2011). To increase the feasibility and applicability of clinical validation of biomarker candidates (nonglycosylated tryptic peptides), we developed a method to effectively monitor nonglycosylated tryptic peptides from a large number of plasma samples and to reduce the total analysis time with maximizing the effect of steric hindrance by the glycans during digestion of glycoproteins. The AUC values of targeted nonglycosylated tryptic peptides were excellent (0.955 for GQYCYELDEK, 0.880 for FEDGVLDPDYPR and 0.907 for TEDTIFLR), indicating that these could be effective biomarkers for hepatocellular carcinoma. This method provides the necessary throughput required to validate glycoprotein biomarkers, as well as quantitative accuracy for human plasma analysis, and should be amenable to clinical use. Difficulties in verifying and validating putative protein biomarkers are often caused by complex sample preparation procedures required to determine their concentrations in a large number of plasma samples. To solve the difficulties, we developed MRM-based protein biomarker assays that greatly reduce complex, time-consuming, and less reproducible sample pretreatment steps in plasma for clinical implementation. First, we used undepleted human plasma samples without any enrichment procedures. Using nanoLC/MS/MS, we targeted nonglycosylated tryptic peptides adjacent to N-linked glycosylation sites in N-linked glycoprotein biomarkers, which could be detected in human plasma samples without depleting highly abundant proteins. Second, human plasma proteins were digested with trypsin without reduction and alkylation procedures to minimize sample preparation. Third, trypsin digestion times were shortened so as to obtain reproducible results with maximization of the steric hindrance effect of the glycans during enzyme digestion. Finally, this rapid and simple sample preparation method was applied to validate targeted nonglycosylated tryptic peptides as liver cancer biomarker candidates for diagnosis in 40 normal and 41 hepatocellular carcinoma (HCC) human plasma samples. This strategy provided the necessary throughput required to monitor protein biomarkers, as well as quantitative accuracy in human plasma analysis. From biomarker discovery to clinical implementation, our method will provide a biomarker study platform that is suitable for clinical deployment, and can be applied to high-throughput approaches. Copyright © 2014 Elsevier B.V. All rights reserved.

  3. Quantitative bioanalysis of strontium in human serum by inductively coupled plasma-mass spectrometry

    PubMed Central

    Somarouthu, Srikanth; Ohh, Jayoung; Shaked, Jonathan; Cunico, Robert L; Yakatan, Gerald; Corritori, Suzana; Tami, Joe; Foehr, Erik D

    2015-01-01

    Aim: A bioanalytical method using inductively-coupled plasma-mass spectrometry to measure endogenous levels of strontium in human serum was developed and validated. Results & methodology: This article details the experimental procedures used for the method development and validation thus demonstrating the application of the inductively-coupled plasma-mass spectrometry method for quantification of strontium in human serum samples. The assay was validated for specificity, linearity, accuracy, precision, recovery and stability. Significant endogenous levels of strontium are present in human serum samples ranging from 19 to 96 ng/ml with a mean of 34.6 ± 15.2 ng/ml (SD). Discussion & conclusion: Calibration procedures and sample pretreatment were simplified for high throughput analysis. The validation demonstrates that the method was sensitive, selective for quantification of strontium (88Sr) and is suitable for routine clinical testing of strontium in human serum samples. PMID:28031925

  4. Validation and use of three complementary analytical methods (LC-FLS, LC-MS/MS and ICP-MS) to evaluate the pharmacokinetics, biodistribution and stability of motexafin gadolinium in plasma and tissues.

    PubMed

    Miles, Dale R; Mesfin, Mimi; Mody, Tarak D; Stiles, Mark; Lee, Jean; Fiene, John; Denis, Bernie; Boswell, Garry W

    2006-05-01

    Liquid chromatography-fluorescence (LC-FLS), liquid chromatography-tandem mass spectrometry (LC-MS/MS) and inductively coupled plasma-mass spectrometry (ICP-MS) methods were developed and validated for the evaluation of motexafin gadolinium (MGd, Xcytrin) pharmacokinetics and biodistribution in plasma and tissues. The LC-FLS method exhibited the greatest sensitivity (0.0057 microg mL(-1)), and was used for pharmacokinetic, biodistribution, and protein binding studies with small sample sizes or low MGd concentrations. The LC-MS/MS method, which exhibited a short run time and excellent selectivity, was used for routine clinical plasma sample analysis. The ICP-MS method, which measured total Gd, was used in conjunction with LC methods to assess MGd stability in plasma. All three methods were validated using human plasma. The LC-FLS method was also validated using plasma, liver and kidneys from mice and rats. All three methods were shown to be accurate, precise and robust for each matrix validated. For three mice, the mean (standard deviation) concentration of MGd in plasma/tissues taken 5 hr after dosing with 23 mg kg(-1) MGd was determined by LC-FLS as follows: plasma (0.025+/-0.002 microg mL(-1)), liver (2.89+/-0.45 microg g(-1)), and kidney (6.09+/-1.05 microg g(-1)). Plasma samples from a subset of patients with brain metastases from extracranial tumors were analyzed using both LC-MS/MS and ICP-MS methods. For a representative patient, > or = 90% of the total Gd in plasma was accounted for as MGd over the first hour post dosing. By 24 hr post dosing, 63% of total Gd was accounted for as MGd, indicating some metabolism of MGd.

  5. An Improved LC-ESI-MS/MS Method to Quantify Pregabalin in Human Plasma and Dry Plasma Spot for Therapeutic Monitoring and Pharmacokinetic Applications.

    PubMed

    Dwivedi, Jaya; Namdev, Kuldeep K; Chilkoti, Deepak C; Verma, Surajpal; Sharma, Swapnil

    2018-06-06

    Therapeutic drug monitoring (TDM) of anti-epileptic drugs provides a valid clinical tool in optimization of overall therapy. However, TDM is challenging due to the high biological samples (plasma/blood) storage/shipment costs and the limited availability of laboratories providing TDM services. Sampling in the form of dry plasma spot (DPS) or dry blood spot (DBS) is a suitable alternative to overcome these issues. An improved, simple, rapid, and stability indicating method for quantification of pregabalin in human plasma and DPS has been developed and validated. Analyses were performed on liquid chromatography tandem mass spectrometer under positive ionization mode of electrospray interface. Pregabain-d4 was used as internal standard, and the chromatographic separations were performed on Poroshell 120 EC-C18 column using an isocratic mobile phase flow rate of 1 mL/min. Stability of pregabalin in DPS was evaluated under simulated real-time conditions. Extraction procedures from plasma and DPS samples were compared using statistical tests. The method was validated considering the FDA method validation guideline. The method was linear over the concentration range of 20-16000 ng/mL and 100-10000 ng/mL in plasma and DPS, respectively. DPS samples were found stable for only one week upon storage at room temperature and for at least four weeks at freezing temperature (-20 ± 5 °C). Method was applied for quantification of pregabalin in over 600 samples of a clinical study. Statistical analyses revealed that two extraction procedures in plasma and DPS samples showed statistically insignificant difference and can be used interchangeably without any bias. Proposed method involves simple and rapid steps of sample processing that do not require a pre- or post-column derivatization procedure. The method is suitable for routine pharmacokinetic analysis and therapeutic monitoring of pregabalin.

  6. Development and validation of a new method to simultaneously quantify triazoles in plasma spotted on dry sample spot devices and analysed by HPLC-MS.

    PubMed

    Baietto, Lorena; D'Avolio, Antonio; Marra, Cristina; Simiele, Marco; Cusato, Jessica; Pace, Simone; Ariaudo, Alessandra; De Rosa, Francesco Giuseppe; Di Perri, Giovanni

    2012-11-01

    Therapeutic drug monitoring (TDM) of triazoles is widely used in clinical practice to optimize therapy. TDM is limited by technical problems and cost considerations, such as sample storage and dry-ice shipping. We aimed to develop and validate a new method to analyse itraconazole, posaconazole and voriconazole in plasma spotted on dry sample spot devices (DSSDs) and to quantify them by an HPLC system. Extraction from DSSDs was done using n-hexane/ethyl acetate and ammonia solution. Samples were analysed using HPLC with mass spectrometry (HPLC-MS). Accuracy and precision were assayed by inter- and intra-day validation. The stability of triazoles in plasma spotted on DSSDs was investigated at room temperature for 1 month. The method was compared with a validated standard HPLC method for quantification of triazoles in human plasma. Mean inter- and intra-day accuracy and precision were <15% for all compounds. Triazoles were stable for 2 weeks at room temperature. The method was linear (r(2) > 0.999) in the range 0.031-8 mg/L for itraconazole and posaconazole, and 0.058-15 mg/L for voriconazole. High sensitivity was observed; limits of detection were 0.008, 0.004 and 0.007 mg/L for itraconazole, posaconazole and voriconazole, respectively. A high degree of correlation (r(2) > 0.94) was obtained between the DSSD method and the standard method of analysis. The method that we developed and validated to quantify triazoles in human plasma spotted on DSSDs is accurate and precise. It overcomes problems related to plasma sample storage and shipment, allowing TDM to be performed in a cheaper and safer manner.

  7. A system of equations to approximate the pharmacokinetic parameters of lacosamide at steady state from one plasma sample.

    PubMed

    Cawello, Willi; Schäfer, Carina

    2014-08-01

    Frequent plasma sampling to monitor pharmacokinetic (PK) profile of antiepileptic drugs (AEDs), is invasive, costly and time consuming. For drugs with a well-defined PK profile, such as AED lacosamide, equations can accurately approximate PK parameters from one steady-state plasma sample. Equations were derived to approximate steady-state peak and trough lacosamide plasma concentrations (Cpeak,ss and Ctrough,ss, respectively) and area under concentration-time curve during dosing interval (AUCτ,ss) from one plasma sample. Lacosamide (ka: ∼2 h(-1); ke: ∼0.05 h(-1), corresponding to half-life of 13 h) was calculated to reach Cpeak,ss after ∼1 h (tmax,ss). Equations were validated by comparing approximations to reference PK parameters obtained from single plasma samples drawn 3-12h following lacosamide administration, using data from double-blind, placebo-controlled, parallel-group PK study. Values of relative bias (accuracy) between -15% and +15%, and root mean square error (RMSE) values≤15% (precision) were considered acceptable for validation. Thirty-five healthy subjects (12 young males; 11 elderly males, 12 elderly females) received lacosamide 100mg/day for 4.5 days. Equation-derived PK values were compared to reference mean Cpeak,ss, Ctrough,ss and AUCτ,ss values. Equation-derived PK data had a precision of 6.2% and accuracy of -8.0%, 2.9%, and -0.11%, respectively. Equation-derived versus reference PK values for individual samples obtained 3-12h after lacosamide administration showed correlation (R2) range of 0.88-0.97 for AUCτ,ss. Correlation range for Cpeak,ss and Ctrough,ss was 0.65-0.87. Error analyses for individual sample comparisons were independent of time. Derived equations approximated lacosamide Cpeak,ss, Ctrough,ss and AUCτ,ss using one steady-state plasma sample within validation range. Approximated PK parameters were within accepted validation criteria when compared to reference PK values. Copyright © 2014 Elsevier B.V. All rights reserved.

  8. Liquid chromatography tandem-mass spectrometry (LC-MS/MS) and dried blood spot sampling applied to pharmacokinetics studies in animals: Correlation of classic and block design.

    PubMed

    Baldo, Matías N; Angeli, Emmanuel; Gareis, Natalia C; Hunzicker, Gabriel A; Murguía, Marcelo C; Ortega, Hugo H; Hein, Gustavo J

    2018-04-01

    A relative bioavailability study (RBA) of two phenytoin (PHT) formulations was conducted in rabbits, in order to compare the results obtained from different matrices (plasma and blood from dried blood spot (DBS) sampling) and different experimental designs (classic and block). The method was developed by liquid chromatography tandem-mass spectrometry (LC-MS/MS) in plasma and blood samples. The different sample preparation techniques, plasma protein precipitation and DBS, were validated according to international requirements. The analytical method was validated with ranges 0.20-50.80 and 0.12-20.32 µg ml -1 , r > 0.999 for plasma and blood, respectively. Accuracy and precision were within acceptance criteria for bioanalytical assay validation (< 15 for bias and CV% and < 20 for limit of quantification (LOQ)). PHT showed long-term stability, both for plasma and blood, and under refrigerated and room temperature conditions. Haematocrit values were measured during the validation process and RBA study. Finally, the pharmacokinetic parameters (C max , T max and AUC 0-t ) obtained from the RBA study were tested. Results were highly comparable for matrices and experimental designs. A matrix correlation higher than 0.975 and a ratio of (PHT blood) = 1.158 (PHT plasma) were obtained. The results obtained herein show that the use of classic experimental design and DBS sampling for animal pharmacokinetic studies should be encouraged as they could help to prevent the use of a large number of animals and also animal euthanasia. Finally, the combination of DBS sampling with LC-MS/MS technology showed to be an excellent tool not only for therapeutic drug monitoring but also for RBA studies.

  9. Simultaneous determination of nicotine, cotinine, and nicotine N-oxide in human plasma, semen, and sperm by LC-Orbitrap MS.

    PubMed

    Abu-Awwad, Ahmad; Arafat, Tawfiq; Schmitz, Oliver J

    2016-09-01

    Nicotine (Nic) distribution in human fluids and tissues has a deleterious effect on human health. In addition to its poisoning profile, Nic may contribute to the particular impact of smoking on human reproduction. Although present in seminal fluid, still nobody knows whether nicotine is available in sperm or not. Herein, we developed and validated a new bioanalytical method, for simultaneous determination of Nic, cotinine (Cot), and nicotine N'-oxide (Nox) in human plasma, semen, and sperm by LC-ESI-orbitrap-MS. Blood and semen samples were collected from 12 healthy smoking volunteers in this study. Sperm bodies were then separated quantitatively from 1 mL of semen samples by centrifugation. The developed method was fully validated for plasma following European and American guidelines for bioanalytical method validation, and partial validation was applied to semen analysis. Plasma, semen, and sperm samples were treated by trichloroacetic acid solution for protein direct precipitation in single extraction step. The established calibration range for Nic and Nox in plasma and semen was linear between 5 and 250 ng/mL, and for Cot between 10 and 500 ng/mL. Nic and Cot were detected in human sperm at concentrations as high as in plasma. In addition, Nox was present in semen and sperm but not in plasma. Graphical abstract Nicotine correlation between plasma and semen a; Nicotine correlation between semen and sperm c; Cotinine correlation between plasma and semen b; Cotinine correlation between semen and sperm d.

  10. A validated method for the quantification of fosfomycin on dried plasma spots by HPLC-MS/MS: application to a pilot pharmacokinetic study in humans.

    PubMed

    Parker, Suzanne L; Lipman, Jeffrey; Dimopoulos, George; Roberts, Jason A; Wallis, Steven C

    2015-11-10

    Quantification of fosfomycin in the plasma samples of patients is the basis of clinical pharmacokinetic studies from which evidence based dosing regimens can be devised to maximise antibiotic effectiveness against a pathogen. We have developed and validated a LC-MS/MS method to quantify fosfomycin using dried plasma spot sampling. Following HILIC chromatography, fosfomycin and ethylphosphonic acid, used as internal standard, were measured using negative-ion multiple reaction monitoring. The method was linear over the calibration range of 5-2000mg/L of fosfomycin. Intra-day assay results for dried plasma spot quality control samples at 15.6, 79.9 and 1581mg/L of fosfomycin had precision of ±4.2, 8.2, and 2.0%, respectively, and accuracy of +3.9, -0.1, and -1.2%, respectively. Recovery of fosfomycin from dried plasma spots was calculated as 83.6% and the dried plasma spot samples were found to be stable stored at room temperature for three months and when stored for four hours at 50°C. A Bland-Altman plot comparing DPS to plasma sampling found a negative bias of 16.6%, with all but one sample within the mean limits of agreement (-2.6 to 30.6%). Dried plasma spot sampling provides a useful tool for pharmacokinetic research of fosfomycin. Copyright © 2015 Elsevier B.V. All rights reserved.

  11. Validation of a LC-fluorescence method for determination of free captopril in human plasma, using a pre-column derivatization reaction with monobromobimane.

    PubMed

    Tache, Florentin; Farca, Alexandru; Medvedovici, Andrei; David, Victor

    2002-05-15

    Both derivatization of free captopril in human plasma samples using monobromobimane as fluorescent label and the corresponding HPLC-fluorescence detection (FLD) method were validated. Calibration curve for the fluorescent captopril derivative in plasma samples is linear in the ppb-ppm range with a detection limit of 4 ppb and an identification limit of 10 ppb (P%: 90; nu > or = 5). These methods were successfully applied on bioequivalence studies carried out on some marketed pharmaceutical formulations.

  12. Development and validation of a liquid chromatography-isotope dilution tandem mass spectrometry for determination of olanzapine in human plasma and its application to bioavailability study.

    PubMed

    Zhang, Meng-Qi; Jia, Jing-Ying; Lu, Chuan; Liu, Gang-Yi; Yu, Cheng-Yin; Gui, Yu-Zhou; Liu, Yun; Liu, Yan-Mei; Wang, Wei; Li, Shui-Jun; Yu, Chen

    2010-06-01

    A simple, reliable and sensitive liquid chromatography-isotope dilution mass spectrometry (LC-ID/MS) was developed and validated for quantification of olanzapine in human plasma. Plasma samples (50 microL) were extracted with tert-butyl methyl ether and isotope-labeled internal standard (olanzapine-D3) was used. The chromatographic separation was performed on XBridge Shield RP 18 (100 mm x 2.1 mm, 3.5 microm, Waters). An isocratic program was used at a flow rate of 0.4 m x min(-1) with mobile phase consisting of acetonitrile and ammonium buffer (pH 8). The protonated ions of analytes were detected in positive ionization by multiple reactions monitoring (MRM) mode. The plasma method, with a lower limit of quantification (LLOQ) of 0.1 ng x mL(-1), demonstrated good linearity over a range of 0.1 - 30 ng x mL(-1) of olanzapine. Specificity, linearity, accuracy, precision, recovery, matrix effect and stability were evaluated during method validation. The validated method was successfully applied to analyzing human plasma samples in bioavailability study.

  13. Determination of efavirenz in human dried blood spots by reversed-phase high-performance liquid chromatography with UV detection.

    PubMed

    Hoffman, Justin T; Rossi, Steven S; Espina-Quinto, Rowena; Letendre, Scott; Capparelli, Edmund V

    2013-04-01

    Previously published methods for determination of efavirenz (EFV) in human dried blood spots (DBS) use costly and complex liquid chromatography/mass spectrometry. We describe the validation and evaluation of a simple and inexpensive high-performance liquid chromatography method for EFV quantification in human DBS and dried plasma spots (DPS), using ultraviolet detection appropriate for resource-limited settings. One hundred microliters of heparinized whole blood or plasma were spotted onto blood collection cards, dried, punched, and eluted. Eluates are injected onto a C-18 reversed phase high-performance liquid chromatography column. EFV is separated isocratically using a potassium phosphate and acetonitrile mobile phase. Ultraviolet detection is at 245 nm. Quantitation is by use of external calibration standards. Following validation, the method was evaluated using whole blood and plasma from HIV-positive patients undergoing EFV therapy. Mean recovery of drug from DBS is 91.5%. The method is linear over the validated concentration range of 0.3125-20.0 μg/mL. A good correlation (Spearman r = 0.96) between paired plasma and DBS EFV concentrations from the clinical samples was observed, and hematocrit level was not found to be a significant determinant of the EFV DBS level. The mean observed C DBS/C plasma ratio was 0.68. A good correlation (Spearman r = 0.96) between paired plasma and DPS EFV concentrations from the clinical samples was observed. The mean percent deviation of DPS samples from plasma samples is 1.68%. Dried whole blood spot or dried plasma spot sampling is well suited for monitoring EFV therapy in resource-limited settings, particularly when high sensitivity is not essential.

  14. Validation of a multiplex electrochemiluminescent immunoassay platform in human and mouse samples

    PubMed Central

    Bastarache, J.A.; Koyama, T.; Wickersham, N.E; Ware, L.B.

    2014-01-01

    Despite the widespread use of multiplex immunoassays, there are very few scientific reports that test the accuracy and reliability of a platform prior to publication of experimental data. Our laboratory has previously demonstrated the need for new assay platform validation prior to use of biologic samples from large studies in order to optimize sample handling and assay performance. In this study, our goal was to test the accuracy and reproducibility of an electrochemiluminescent multiplex immunoassay platform (Meso Scale Discovery, MSD®) and compare this platform to validated, singleplex immunoassays (R&D Systems®) using actual study subject (human plasma and mouse bronchoalveolar lavage fluid (BALF) and plasma) samples. We found that the MSD platform performed well on intra- and inter-assay comparisons, spike and recovery and cross-platform comparisons. The mean intra-assay CV% and range for MSD was 3.49 (0.0-10.4) for IL-6 and 2.04 (0.1-7.9) for IL-8. The correlation between values for identical samples measured on both MSD and R&D was R=0.97 for both analytes. The mouse MSD assay had a broader range of CV% with means ranging from 9.5-28.5 depending on the analyte. The range of mean CV% was similar for single plex ELISAs at 4.3-23.7 depending on the analyte. Regardless of species or sample type, CV% was more variable at lower protein concentrations. In conclusion, we validated a multiplex electrochemiluminscent assay system and found that it has superior test characteristics in human plasma compared to mouse BALF and plasma. Both human and MSD assays compared favorably to well-validated singleplex ELISA's PMID:24768796

  15. Determination of Efavirenz in Human Dried Blood Spots by Reversed-Phase High Performance Liquid Chromatography with UV Detection

    PubMed Central

    Hoffman, Justin T; Rossi, Steven S; Espina-Quinto, Rowena; Letendre, Scott; Capparelli, Edmund V

    2013-01-01

    Background Previously published methods for determination of efavirenz (EFV) in human dried blood spots (DBS) employ costly and complex liquid chromatography/mass spectrometry. We describe the validation and evaluation of a simple and inexpensive high-performance liquid chromatography (HPLC) method for EFV quantification in human DBS and dried plasma spots (DPS), using ultraviolet (UV) detection appropriate for resource-limited settings. Methods 100μl of heparinized whole blood or plasma were spotted onto blood collection cards, dried, punched, and eluted. Eluates are injected onto a C-18 reversed phase HPLC column. EFV is separated isocratically using a potassium phosphate and ACN mobile phase. UV detection is at 245nm. Quantitation is by use of external calibration standards. Following validation, the method was evaluated using whole blood and plasma from HIV-positive patients undergoing EFV therapy. Results Mean recovery of drug from dried blood spots is 91.5%. The method is linear over the validated concentration range of 0.3125 – 20.0μg/mL. A good correlation (Spearman r=0.96) between paired plasma and DBS EFV concentrations from the clinical samples was observed, and hematocrit level was not found to be a significant determinant of the EFV DBS level. The mean observed CDBS/Cplasma ratio was 0.68. A good correlation (Spearman r=0.96) between paired plasma and DPS EFV concentrations from the clinical samples was observed. The mean percent deviation of DPS samples from plasma samples is 1.68%. Conclusions Dried whole blood spot or dried plasma spot sampling is well suited for monitoring EFV therapy in resource limited settings, particularly when high sensitivity is not essential. PMID:23503446

  16. Simultaneous determination of trimethoprim and sulfamethoxazole in dried plasma and urine spots.

    PubMed

    Gonzalez, Daniel; Melloni, Chiara; Poindexter, Brenda B; Yogev, Ram; Atz, Andrew M; Sullivan, Janice E; Mendley, Susan R; Delmore, Paula; Delinsky, Amy; Zimmerman, Kanecia; Lewandowski, Andrew; Harper, Barrie; Lewis, Kenneth C; Benjamin, Daniel K; Cohen-Wolkowiez, Michael

    2015-01-01

    Trimethoprim-sulfamethoxazole (TMP-SMX) is an antimicrobial drug combination commonly prescribed in children and adults. The study objectives were to validate and apply an HPLC-MS/MS method to quantify TMP-SMX in dried plasma spots (DPS) and dried urine spots (DUS), and perform a comparability analysis with liquid matrices. For TMP the validated range was 100-50,000 ng/ml for DPS and 500-250,000 ng/ml for DUS; for SMX, the validated range was 1000-500,000 ng/ml for both DPS and DUS. Good agreement was noted between DPS/DUS and liquid plasma and urine samples for TMP, while only modest agreement was observed for SMX in both matrices. A precise, accurate and reproducible method was developed to quantify TMP-SMX in DPS and DUS samples.

  17. Validation of a Commercially Available Enzyme ImmunoAssay for the Determination of Oxytocin in Plasma Samples from Seven Domestic Animal Species.

    PubMed

    Bienboire-Frosini, Cecile; Chabaud, Camille; Cozzi, Alessandro; Codecasa, Elisa; Pageat, Patrick

    2017-01-01

    The neurohormone oxytocin (OT) has a broad range of behavioral effects in mammals. It modulates a multitude of social behaviors, e.g., affiliative and sexual interactions. Consequently, the OT role in various animal species is increasingly explored. However, several issues have been raised regarding the peripheral OT measurement. Indeed, various methods have been described, leading to assay discrepancies and inconsistent results. This highlights the need for a recognized and reliable method to measure peripheral OT. Our aim was to validate a method combining a pre-extraction step, previously demonstrated as essential by several authors, and a commercially available enzyme immunoassay (EIA) for OT measurement, using plasma from seven domestic species (cat, dog, horse, cow, pig, sheep, and goat). The Oxytocin EIA kit (EnzoLifeSciences) was used to assay the solid-phase extracted samples following the manufacturer's instructions with slight modifications. For all species except dogs and cats, concentration factors were applied to work above the kit's sensitivity (15 pg/ml). To validate the method, the following performance characteristics were evaluated using Validation Samples (VS) at various concentrations in each species: extraction efficiency via spiking tests and intra- and inter-assay precision, allowing for the calculation of total errors. Parallelism studies to assess matrix effects could not be performed because of too low basal concentrations. Quantification ranges and associated precision profiles were established to account for the various OT plasma concentrations in each species. According to guidelines for bioanalytical validation of immunoassays, the measurements were sufficiently precise and accurate in each species to achieve a total error ≤30% in each VS sample. In each species, the inter-assay precision after 3 runs was acceptable, except in low concentration samples. The linearity under dilution of dogs and cats' samples was verified. Although matrix effects assessments are lacking, our results indicate that OT plasma levels can reliably be measured in several domestic animal species by the method described here. Studies involving samples with low OT plasma concentrations should pay attention to reproducibility issues. This work opens new perspectives to reliably study peripheral OT in a substantial number of domestic animal species in various behavioral contexts.

  18. Simultaneous determination of dextromethorphan, dextrorphan, and guaifenesin in human plasma using semi-automated liquid/liquid extraction and gradient liquid chromatography tandem mass spectrometry.

    PubMed

    Eichhold, Thomas H; McCauley-Myers, David L; Khambe, Deepa A; Thompson, Gary A; Hoke, Steven H

    2007-01-17

    A method for the simultaneous determination of dextromethorphan (DEX), dextrorphan (DET), and guaifenesin (GG) in human plasma was developed, validated, and applied to determine plasma concentrations of these compounds in samples from six clinical pharmacokinetic (PK) studies. Semi-automated liquid handling systems were used to perform the majority of the sample manipulation including liquid/liquid extraction (LLE) of the analytes from human plasma. Stable-isotope-labeled analogues were utilized as internal standards (ISTDs) for each analyte to facilitate accurate and precise quantification. Extracts were analyzed using gradient liquid chromatography coupled with tandem mass spectrometry (LC-MS/MS). Use of semi-automated LLE with LC-MS/MS proved to be a very rugged and reliable approach for analysis of more than 6200 clinical study samples. The lower limit of quantification was validated at 0.010, 0.010, and 1.0 ng/mL of plasma for DEX, DET, and GG, respectively. Accuracy and precision of quality control (QC) samples for all three analytes met FDA Guidance criteria of +/-15% for average QC accuracy with coefficients of variation less than 15%. Data from the thorough evaluation of the method during development, validation, and application are presented to characterize selectivity, linearity, over-range sample analysis, accuracy, precision, autosampler carry-over, ruggedness, extraction efficiency, ionization suppression, and stability. Pharmacokinetic data are also provided to illustrate improvements in systemic drug and metabolite concentration-time profiles that were achieved by formulation optimization.

  19. Analytical validation of bovine plasma ceruloplasmin measurement by p-phenylenediamine oxidation and effect of storage time and freezing temperature.

    PubMed

    Hussein, Hussein Awad; Staufenbiel, Rudolf

    2017-10-04

    Determination of ceruloplasmin (Cp) activity in plasma can provide an objective measure of the health of dairy cows as well as it can be used for various diagnostic purposes. The current study was designed to perform an analytical validation of a method for the determination of plasma Cp activity in dairy cows and to evaluate the influences of plasma storage times and temperatures as well as freeze-thaw cycles on the activity of this enzyme. This cohort was carried out on ten cows. For each cow, 24 aliquots of plasma, which were stored at different temperature regimes, were prepared. Both intra- and interassay coefficients of variation (CVs) were determined. The linearity was evaluated using bovine plasma Cp standard. The mean values of intra- and interassay CVs were 1.08 and 2.12%, respectively. Results of linearity testing showed a high correlation coefficient (r = 0.998, P < 0.001). After 3 days of storage at room temperature and refrigeration, the plasma activity of Cp was significantly lowered (P < 0.05). Plasma samples kept at freezing for 3 months revealed insignificant changes in the activity of Cp. Repeated freeze-thaw cycles for three times had no significant influence on the activity of Cp. The method is easy and may be valid at values of Cp ranging from 100 to 1000 mg/L. It seems that keeping of plasma samples at room temperature and refrigeration longer than 3 days is unsuitable for Cp measurement. In addition, Cp remains stable in plasma samples stored at freezing as well as repeat freeze-thaw cycles.

  20. A simple, rapid and stability indicating validated method for quantification of lamotrigine in human plasma and dry plasma spot using LC-ESI-MS/MS: Application in clinical study.

    PubMed

    Namdev, Kuldeep Kumar; Dwivedi, Jaya; Chilkoti, Deepak Chandra; Sharma, Swapnil

    2018-01-01

    Lamotrigine (LTZ) is a phenyltriazine derivative which belongs to anti-epileptic drugs (AEDs) class and prescribed as mono- or adjunctive-therapy in treatment of epilepsy. Therapeutic drug monitoring (TDM) of AEDs provides a valid clinical tool in optimization of overall therapy. However, TDM is challenging due to the high biological samples (plasma/blood) storage/shipment costs and the limited availability of laboratories providing TDM services. Sampling in the form of dry plasma spot (DPS) or dry blood spot (DBS) are suitable alternative to overcome these issues. We developed and validated a new method for quantification of LTZ in human plasma and DPS. The extraction of LTZ from plasma and DPS was performed using liquid-liquid extraction with diethyl ether and an extraction solution composed of diethyl ether- methyl tert-butyl ether- acetone (50:30:20, v/v/v), respectively. Lamotrigine- 13C3, d3 was used as internal standard (ISTD) and the chromatographic separation was achieved on Hypurity Advance C18 column (150×4.6mm, 5μm). Quantitative estimation of LTZ and ISTD was performed on a liquid chromatography tandem mass spectrometer coupled with electrospray ionization interface operated under positive mode of ionization. Calibration curves were linear (r 2 >0.99) over the concentration range of 10-3020ng/mL for both plasma and DPS. Statistical analysis provides insignificant difference between LTZ concentration extracted from plasma and DPS samples. The method is found suitable for application in clinical study and in therapeutic monitoring of LTZ. To the best of our knowledge this is the first report which describing a validated stability indicating assay for quantification of LTZ in dry plasma spot. Copyright © 2017 Elsevier B.V. All rights reserved.

  1. Development and validation of a sensitive HPLC method for the quantification of HI-6 in guinea pig plasma and evaluated in domestic swine.

    PubMed

    Bohnert, Sara; Vair, Cory; Mikler, John

    2010-05-15

    A rapid and small volume assay to quantify HI-6 in plasma was developed to further the development and licensing of an intravenous formulation of HI-6. The objective of this method was to develop a sensitive and rapid assay that clearly resolved HI-6 and an internal standard in saline and plasma matrices. A fully validated method using ion-pair HPLC and 2-PAM as the internal standard fulfilled these requirements. Small plasma samples of 35 microL were extracted using acidification, filtration and neutralization. Linearity was shown for over 4 microg/mL to 1mg/mL with accuracy and precision within 6% relative error at the lower limit of detection. This method was utilized in the pharmacokinetic analysis HI-6 dichloride (2Cl) and HI-6 dimethane sulfonate (DMS) in anaesthetized guinea pigs and domestic swine following an intravenous bolus administration. From the resultant pharmacokinetic parameters a target plasma concentration of 100 microM was established and maintained in guinea pigs receiving an intravenous infusion. This validated method allows for the analysis of low volume samples, increased sample numbers and is applicable to the determination of pharmacokinetic profiles and parameters. Copyright (c) 2010. Published by Elsevier B.V.

  2. Validation of a simple HPLC-UV method for rifampicin determination in plasma: Application to the study of rifampicin arteriovenous concentration gradient.

    PubMed

    Goutal, Sébastien; Auvity, Sylvain; Legrand, Tiphaine; Hauquier, Fanny; Cisternino, Salvatore; Chapy, Hélène; Saba, Wadad; Tournier, Nicolas

    2016-05-10

    In clinical practice, rifampicin exposure is estimated from its concentration in venous blood samples. In this study, we hypothesized that differences in rifampicin concentration may exist between arterial and venous plasma. An HPLC-UV method for determining rifampicin concentration in plasma using rifapentine as an internal standard was validated. The method, which requires a simple protein precipitation procedure as sample preparation, was performed to compare venous and arterial plasma kinetics after a single therapeutic dose of rifampicin (8.6 mg/kg i.v, infused over 30 min) in baboons (n=3). The method was linear from 0.1 to 40 μg mL(-1) and all validation parameters fulfilled the international requirements. In baboons, rifampicin concentration in arterial plasma was higher than in venous plasma. Arterial Cmax was 2.1±0.2 fold higher than venous Cmax. The area under the curve (AUC) from 0 to 120 min was ∼80% higher in arterial plasma, indicating a significant arteriovenous concentration gradient in early rifampicin pharmacokinetics. Arterial and venous plasma concentrations obtained 6h after rifampicin injection were not different. An important arteriovenous equilibration delay for rifampicin pharmacokinetics is reported. Determination in venous plasma concentrations may considerably underestimate rifampicin exposure to organs during the distribution phase. Copyright © 2016 Elsevier B.V. All rights reserved.

  3. Simultaneous determination of trimethoprim and sulfamethoxazole in dried plasma and urine spots

    PubMed Central

    Gonzalez, Daniel; Melloni, Chiara; Poindexter, Brenda B; Yogev, Ram; Atz, Andrew M; Sullivan, Janice E; Mendley, Susan R; Delmore, Paula; Delinsky, Amy; Zimmerman, Kanecia; Lewandowski, Andrew; Harper, Barrie; Lewis, Kenneth C; Benjamin, Daniel K; Cohen-Wolkowiez, Michael

    2015-01-01

    Background: Trimethoprim-sulfamethoxazole (TMP-SMX) is an antimicrobial drug combination commonly prescribed in children and adults. The study objectives were to validate and apply an HPLC–MS/MS method to quantify TMP-SMX in dried plasma spots (DPS) and dried urine spots (DUS), and perform a comparability analysis with liquid matrices. Results: For TMP the validated range was 100–50,000 ng/ml for DPS and 500–250,000 ng/ml for DUS; for SMX, the validated range was 1000–500,000 ng/ml for both DPS and DUS. Good agreement was noted between DPS/DUS and liquid plasma and urine samples for TMP, while only modest agreement was observed for SMX in both matrices. Conclusion: A precise, accurate and reproducible method was developed to quantify TMP-SMX in DPS and DUS samples. PMID:26039810

  4. Experimental Validation Plan for the Xolotl Plasma-Facing Component Simulator Using Tokamak Sample Exposures

    NASA Astrophysics Data System (ADS)

    Chan, V. S.; Wong, C. P. C.; McLean, A. G.; Luo, G. N.; Wirth, B. D.

    2013-10-01

    The Xolotl code under development by PSI-SciDAC will enhance predictive modeling capability of plasma-facing materials under burning plasma conditions. The availability and application of experimental data to compare to code-calculated observables are key requirements to validate the breadth and content of physics included in the model and ultimately gain confidence in its results. A dedicated effort has been in progress to collect and organize a) a database of relevant experiments and their publications as previously carried out at sample exposure facilities in US and Asian tokamaks (e.g., DIII-D DiMES, and EAST MAPES), b) diagnostic and surface analysis capabilities available at each device, and c) requirements for future experiments with code validation in mind. The content of this evolving database will serve as a significant resource for the plasma-material interaction (PMI) community. Work supported in part by the US Department of Energy under GA-DE-SC0008698, DE-AC52-07NA27344 and DE-AC05-00OR22725.

  5. DBS-LC-MS/MS assay for caffeine: validation and neonatal application.

    PubMed

    Bruschettini, Matteo; Barco, Sebastiano; Romantsik, Olga; Risso, Francesco; Gennai, Iulian; Chinea, Benito; Ramenghi, Luca A; Tripodi, Gino; Cangemi, Giuliana

    2016-09-01

    DBS might be an appropriate microsampling technique for therapeutic drug monitoring of caffeine in infants. Nevertheless, its application presents several issues that still limit its use. This paper describes a validated DBS-LC-MS/MS method for caffeine. The results of the method validation showed an hematocrit dependence. In the analysis of 96 paired plasma and DBS clinical samples, caffeine levels measured in DBS were statistically significantly lower than in plasma but the observed differences were independent from hematocrit. These results clearly showed the need for extensive validation with real-life samples for DBS-based methods. DBS-LC-MS/MS can be considered to be a good alternative to traditional methods for therapeutic drug monitoring or PK studies in preterm infants.

  6. Quantification of vosaroxin and its metabolites N-desmethylvosaroxin and O-desmethylvosaroxin in human plasma and urine using high-performance liquid chromatography-tandem mass spectrometry.

    PubMed

    Nijenhuis, C M; Lucas, L; Rosing, H; Jamieson, G; Fox, J A; Schellens, J H M; Beijnen, J H

    2016-08-01

    Vosaroxin is a first-in-class anticancer quinolone derivative topoisomerase II inhibitor that is currently in development in combination with cytarabine for the treatment of acute myeloid leukemia (AML). To investigate vosaroxin pharmacokinetics (PK) in patients, liquid chromatography tandem mass spectrometry (LC-MS/MS) assays to quantify vosaroxin and the two metabolites N-desmethylvosaroxin and O-desmethylvosaroxin in human plasma and urine were developed and validated. Immediately after collection the samples were stored at -80°C. Prior to analysis, the plasma samples were subjected to protein precipitation and the urine samples were diluted. For both assays the reconstituted extracts were injected on a Symmetry Shield RP8 column and gradient elution was applied using 0.1% formic acid in water and acetonitrile-methanol (50:50, v/v). Analyses were performed with a triple quadruple mass spectrometer in positive-ion mode. A deuterated isotope of vosaroxin was used as internal standard for the quantification. The validated assays quantify vosaroxin and N-desmethylvosaroxin in the concentration range of 2-500ng/mL in plasma and urine. For O-desmethylvosaroxin the concentration range of 4-500ng/mL in plasma and urine was validated. Dilution integrity experiments show that samples can be diluted 25 fold in control matrix prior to analysis. The expanded concentration range for plasma and urine for vosaroxin and N-desmethylvosaroxin is therefore from 2 to 15,000ng/mL and in plasma for O-desmethylvosaroxin from 4 to 15,000ng/mL. Copyright © 2016 Elsevier B.V. All rights reserved.

  7. Quantification and clinical application of carboplatin in plasma ultrafiltrate.

    PubMed

    Downing, Kim; Jensen, Berit Packert; Grant, Sue; Strother, Matthew; George, Peter

    2017-05-10

    Carboplatin is a chemotherapy drug used in a variety of cancers with the primary toxicity being exposure-dependant myelosuppression. We present the development and validation of a simple, robust inductively coupled plasma mass spectrometry (ICP-MS) method to measure carboplatin in plasma ultrafiltrate. Plasma ultrafiltrates samples were prepared using Amicon Ultra 30,000da cut-off filters and then diluted with ammonia EDTA before ICP-MS analysis. The assay was validated in the range 0.19-47.5mg/L carboplatin in ultrafiltrate. The assay was linear (r 2 >0.9999), accurate (<6% bias, 12% bias at LLOQ) and precise (intra- and inter-day precision of <3% coefficient of variation). No matrix effects were observed between plasma ultrafiltrate and aqueous platinum calibrators and recovery was complete. The assay was applied to 10 clinical samples from patients receiving carboplatin. Incurred sample reanalysis showed reproducible values over 3 analysis days (<6% CV). As plasma stability prior to ultrafiltration has been a major concern in previous clinical studies this was studied extensively at room temperature (22°C) over 24h. Carboplatin was found to be stable in both spiked plasma (n=3) and real patient samples (n=10) at room temperature for up to 8h before ultrafiltration. This makes routine measurement of carboplatin concentrations in clinical settings feasible. Copyright © 2017 Elsevier B.V. All rights reserved.

  8. Development and validation of UHPLC-MS/MS methods for the quantification of colistin in plasma and dried plasma spots.

    PubMed

    Cangemi, Giuliana; Barco, Sebastiano; Castagnola, Elio; Tripodi, Gino; Favata, Fabio; D'Avolio, Antonio

    2016-09-10

    Quantification of colistin in plasma samples may be very useful in optimizing therapy especially in special patients' population. Nevertheless, therapeutic drug monitoring of colistin is still limited probably for the low number of laboratories which perform this analysis and for high shipment costs. We developed and validated new UHPLC-MS/MS methods to quantify colistin in plasma and in dried plasma spots (DPS) collected on dried sample spots devices (DSSD). Colistin A, Colistin B and polimixin B, used as internal standard, were detected using multiple reaction monitoring (MRM) of the following specific transitions: 585.5→534.9; 576, 578.5→527.9; 568.9 and 602.5→100.9, 551.9, 592.8, respectively. Colistin A and B were extracted from plasma using protein precipitation and from DSSD using an extraction basic solution. Both methods were validated, and the mean intra and inter-day accuracies and precisions were in accordance with FDA and EMA guidelines. Colistin in DPS was found to be stable for at least one week at room temperature (20-25°C). A statistically significant linear correlation was found between colistin extracted from plasma and from DPS [r(2) 0.9864 (P<0.0001, 95% CI 0.9699-0.9939) for colistin A and 0.9695 (P<0.0001, 95% CI 0.9310-0.9866) for colistin B, respectively]. DPS on DSSD represents a safe and cheap strategy to store and ship at room temperature plasma samples. Thus, it is suited for pharmacokinetic studies and therapeutic drug monitoring of colistin. Copyright © 2016 Elsevier B.V. All rights reserved.

  9. IL8 and IL16 levels indicate serum and plasma quality.

    PubMed

    Kofanova, Olga; Henry, Estelle; Quesada, Rocio Aguilar; Bulla, Alexandre; Linares, Hector Navarro; Lescuyer, Pierre; Shea, Kathi; Stone, Mars; Tybring, Gunnel; Bellora, Camille; Betsou, Fay

    2018-02-09

    Longer pre-centrifugation times alter the quality of serum and plasma samples. Markers for such delays in sample processing and hence for the sample quality, have been identified. Twenty cytokines in serum, EDTA plasma and citrate plasma samples were screened for changes in concentration induced by extended blood pre-centrifugation delays at room temperature. The two cytokines that showed the largest changes were further validated for their "diagnostic performance" in identifying serum or plasma samples with extended pre-centrifugation times. In this study, using R&D Systems ELISA kits, EDTA plasma samples and serum samples with a pre-centrifugation delay longer than 24 h had an IL16 concentration higher than 313 pg/mL, and an IL8 concentration higher than 125 pg/mL, respectively. EDTA plasma samples with a pre-centrifugation delay longer than 48 h had an IL16 concentration higher than 897 pg/mL, citrate plasma samples had an IL8 concentration higher than 21.5 pg/mL and serum samples had an IL8 concentration higher than 528 pg/mL. These robust and accurate tools, based on simple and commercially available ELISA assays can greatly facilitate qualification of serum and plasma legacy collections with undocumented pre-analytics.

  10. Validation of a Plasma-Based Comprehensive Cancer Genotyping Assay Utilizing Orthogonal Tissue- and Plasma-Based Methodologies.

    PubMed

    Odegaard, Justin I; Vincent, John J; Mortimer, Stefanie; Vowles, James V; Ulrich, Bryan C; Banks, Kimberly C; Fairclough, Stephen R; Zill, Oliver A; Sikora, Marcin; Mokhtari, Reza; Abdueva, Diana; Nagy, Rebecca J; Lee, Christine E; Kiedrowski, Lesli A; Paweletz, Cloud P; Eltoukhy, Helmy; Lanman, Richard B; Chudova, Darya I; Talasaz, AmirAli

    2018-04-24

    Purpose: To analytically and clinically validate a circulating cell-free tumor DNA sequencing test for comprehensive tumor genotyping and demonstrate its clinical feasibility. Experimental Design: Analytic validation was conducted according to established principles and guidelines. Blood-to-blood clinical validation comprised blinded external comparison with clinical droplet digital PCR across 222 consecutive biomarker-positive clinical samples. Blood-to-tissue clinical validation comprised comparison of digital sequencing calls to those documented in the medical record of 543 consecutive lung cancer patients. Clinical experience was reported from 10,593 consecutive clinical samples. Results: Digital sequencing technology enabled variant detection down to 0.02% to 0.04% allelic fraction/2.12 copies with ≤0.3%/2.24-2.76 copies 95% limits of detection while maintaining high specificity [prevalence-adjusted positive predictive values (PPV) >98%]. Clinical validation using orthogonal plasma- and tissue-based clinical genotyping across >750 patients demonstrated high accuracy and specificity [positive percent agreement (PPAs) and negative percent agreement (NPAs) >99% and PPVs 92%-100%]. Clinical use in 10,593 advanced adult solid tumor patients demonstrated high feasibility (>99.6% technical success rate) and clinical sensitivity (85.9%), with high potential actionability (16.7% with FDA-approved on-label treatment options; 72.0% with treatment or trial recommendations), particularly in non-small cell lung cancer, where 34.5% of patient samples comprised a directly targetable standard-of-care biomarker. Conclusions: High concordance with orthogonal clinical plasma- and tissue-based genotyping methods supports the clinical accuracy of digital sequencing across all four types of targetable genomic alterations. Digital sequencing's clinical applicability is further supported by high rates of technical success and biomarker target discovery. Clin Cancer Res; 1-11. ©2018 AACR. ©2018 American Association for Cancer Research.

  11. Development and validation of a UPLC-MS/MS method for simultaneous determination of fotagliptin and its two major metabolites in human plasma and urine.

    PubMed

    Wang, Zhenlei; Jiang, Ji; Hu, Pei; Zhao, Qian

    2017-02-01

    Fotagliptin is a novel dipeptidyl peptidase IV inhibitor under clinical development for the treatment of Type II diabetes mellitus. The objective of this study was to develop and validate a specific and sensitive ultra-performance liquid chromatography (UPLC)-MS/MS method for simultaneous determination of fotagliptin and its two major metabolites in human plasma and urine. Methodology & results: After being pretreated using an automatized procedure, the plasma and urine samples were separated and detected using a UPLC-ESI-MS/MS method, which was validated following the international guidelines. A selective and sensitive UPLC-MS/MS method was first developed and validated for quantifying fotagliptin and its metabolite in human plasma and urine. The method was successfully applied to support the clinical study of fotagliptin in Chinese healthy subjects.

  12. LC-MS/MS determination of 2-(4-((2-(2S,5R)-2-Cyano-5-ethynyl-1-pyrrolidinyl)-2-oxoethylamino)-4-methyl-1-piperidinyl)-4-pyridinecarboxylic acid (ABT-279) in dog plasma with high-throughput protein precipitation sample preparation.

    PubMed

    Kim, Joseph; Flick, Jeanette; Reimer, Michael T; Rodila, Ramona; Wang, Perry G; Zhang, Jun; Ji, Qin C; El-Shourbagy, Tawakol A

    2007-11-01

    As an effective DPP-IV inhibitor, 2-(4-((2-(2S,5R)-2-Cyano-5-ethynyl-1-pyrrolidinyl)-2-oxoethylamino)-4-methyl-1-piperidinyl)-4-pyridinecarboxylic acid (ABT-279), is an investigational drug candidate under development at Abbott Laboratories for potential treatment of type 2 diabetes. In order to support the development of ABT-279, multiple analytical methods for an accurate, precise and selective concentration determination of ABT-279 in different matrices were developed and validated in accordance with the US Food and Drug Administration Guidance on Bioanalytical Method Validation. The analytical method for ABT-279 in dog plasma was validated in parallel to other validations for ABT-279 determination in different matrices. In order to shorten the sample preparation time and increase method precision, an automated multi-channel liquid handler was used to perform high-throughput protein precipitation and all other liquid transfers. The separation was performed through a Waters YMC ODS-AQ column (2.0 x 150 mm, 5 microm, 120 A) with a mobile phase of 20 mm ammonium acetate in 20% acetonitrile at a flow rate of 0.3 mL/min. Data collection started at 2.2 min and continued for 2.0 min. The validated linear dynamic range in dog plasma was between 3.05 and 2033.64 ng/mL using a 50 microL sample volume. The achieved r(2) coefficient of determination from three consecutive runs was between 0.998625 and 0.999085. The mean bias was between -4.1 and 4.3% for all calibration standards including lower limit of quantitation. The mean bias was between -8.0 and 0.4% for the quality control samples. The precision, expressed as a coefficient of variation (CV), was < or =4.1% for all levels of quality control samples. The validation results demonstrated that the high-throughput method was accurate, precise and selective for the determination of ABT-279 in dog plasma. The validated method was also employed to support two toxicology studies. The passing rate was 100% for all 49 runs from one validation study and two toxicology studies. Copyright (c) 2007 John Wiley & Sons, Ltd.

  13. Salivary caffeine concentrations are comparable to plasma concentrations in preterm infants receiving extended caffeine therapy

    PubMed Central

    Liu, Xiaoxi; Rhein, Lawrence M.; Darnall, Robert A.; Corwin, Michael J.; McEntire, Betty L.; Ward, Robert M.; James, Laura P.; Sherwin, Catherine M. T.; Heeren, Timothy C.; Hunt, Carl E.

    2016-01-01

    Aims Caffeine concentrations in preterm infants are usually measured in the blood. However, salivary assays may provide a valid and practical alternative. The present study explored the validity and clinical utility of salivary caffeine concentrations as an alternative to blood concentrations and developed a novel plasma/salivary caffeine distribution model. Methods Paired salivary and plasma samples were obtained in 29 infants. Salivary samples were obtained using a commercially available salivary collection system. Caffeine concentrations in the saliva and plasma were determined using high‐performance liquid chromatography. A population pharmacokinetic (PK) model was developed using NONMEM 7.3. Results The mean (± standard deviation) gestational age (GA) at birth and birth weight were 27.9 ± 2.1 weeks and 1171.6 ± 384.9 g, respectively. Paired samples were obtained at a mean postmenstrual age (PMA) of 35.5 ± 1.1 weeks. The range of plasma caffeine concentrations was 9.5–54.1 μg ml−1, with a mean difference (95% confidence interval) between plasma and salivary concentrations of −0.18 μg ml−1 (−1.90, 1.54). Salivary and plasma caffeine concentrations were strongly correlated (Pearson's correlation coefficient = 0.87, P < 0.001). Caffeine PK in plasma and saliva was simultaneously described by a three‐compartment recirculation model. Current body weight, birth weight, GA, PMA and postnatal age were not significantly correlated with any PK parameter. Conclusions Salivary sampling provides an easy, non‐invasive method for measuring caffeine concentrations. Salivary concentrations correlate highly with plasma concentrations. Caffeine PK in saliva and plasma are well described by a three‐compartment recirculation model. PMID:27145974

  14. A validated ultra-high-performance liquid chromatography-tandem mass spectrometry method for the selective analysis of free and total folate in plasma and red blood cells.

    PubMed

    Kiekens, Filip; Van Daele, Jeroen; Blancquaert, Dieter; Van Der Straeten, Dominique; Lambert, Willy E; Stove, Christophe P

    2015-06-12

    A stable isotope dilution LC-MS/MS method is the method of choice for the selective quantitative determination of several folate species in clinical samples. By implementing an integrated approach to determine both the plasma and red blood cell (RBC) folate status, the use of consumables and time remains limited. Starting from a single 300μl whole blood sample, the folate status in plasma and RBCs can be determined after separating plasma and RBCs and sequential washing of the latter with isotonic buffer, followed by reproducible lysis using an ammonium-based buffer. Acidification combines both liberation of protein bound folates and protein precipitation. Sample cleanup is performed using a 96-well reversed-phase solid-phase extraction procedure, similar for both plasma and RBC samples. Analyses are performed by UHPLC-MS/MS. Method validation was successfully performed based on EMA-guidelines and encompassed selectivity, carry-over, linearity, accuracy, precision, recovery, matrix effect and stability. Plasma and RBC folates could be quantified in the range of 1-150nmol/l and 5-1500nmol/l, respectively. This method allows for the determination of 6 folate monoglutamates in both plasma and RBCs. It can be used to determine short and long term folate status in both normal and severely deficient subjects in a single analytical sequence. Copyright © 2015 Elsevier B.V. All rights reserved.

  15. TK Modeler version 1.0, a Microsoft® Excel®-based modeling software for the prediction of diurnal blood/plasma concentration for toxicokinetic use.

    PubMed

    McCoy, Alene T; Bartels, Michael J; Rick, David L; Saghir, Shakil A

    2012-07-01

    TK Modeler 1.0 is a Microsoft® Excel®-based pharmacokinetic (PK) modeling program created to aid in the design of toxicokinetic (TK) studies. TK Modeler 1.0 predicts the diurnal blood/plasma concentrations of a test material after single, multiple bolus or dietary dosing using known PK information. Fluctuations in blood/plasma concentrations based on test material kinetics are calculated using one- or two-compartment PK model equations and the principle of superposition. This information can be utilized for the determination of appropriate dosing regimens based on reaching a specific desired C(max), maintaining steady-state blood/plasma concentrations, or other exposure target. This program can also aid in the selection of sampling times for accurate calculation of AUC(24h) (diurnal area under the blood concentration time curve) using sparse-sampling methodologies (one, two or three samples). This paper describes the construction, use and validation of TK Modeler. TK Modeler accurately predicted blood/plasma concentrations of test materials and provided optimal sampling times for the calculation of AUC(24h) with improved accuracy using sparse-sampling methods. TK Modeler is therefore a validated, unique and simple modeling program that can aid in the design of toxicokinetic studies. Copyright © 2012 Elsevier Inc. All rights reserved.

  16. Bacteria-killing ability of fresh blood plasma compared to frozen blood plasma

    DOE PAGES

    Jacobs, Anne C.; Fair, Jeanne Marie

    2015-10-09

    In recent years, the bacteria-killing assay (BKA) has become a popular technique among ecoimmunologists. New variations of that assay allow researchers to use smaller volumes of blood, an important consideration for those working on small-bodied animals. However, this version of the assay requires access to a lab with a nanodrop spectrophotometer, something that may not be available in the field. One possible solution is to freeze plasma for transport; however, this assumes that frozen plasma samples will give comparable results to fresh ones. Here, we tested this assumption using plasma samples from three species of birds: chickens (Gallus gallus), ash-throatedmore » flycatchers (Myiarchus cinerascens), and western bluebirds (Sialia mexicana). Chicken plasma samples lost most or all of their bacterial killing ability after freezing. This did not happen in flycatchers and bluebirds; however, frozen plasma did not produce results comparable to those obtained using fresh plasma. Finally, we caution researchers using the BKA to use fresh samples whenever possible, and to validate the use of frozen samples on a species-by-species basis.« less

  17. Bacteria-killing ability of fresh blood plasma compared to frozen blood plasma.

    PubMed

    Jacobs, Anne C; Fair, Jeanne M

    2016-01-01

    In recent years, the bacteria-killing assay (BKA) has become a popular technique among ecoimmunologists. New variations of that assay allow researchers to use smaller volumes of blood, an important consideration for those working on small-bodied animals. However, this version of the assay requires access to a lab with a nanodrop spectrophotometer, something that may not be available in the field. One possible solution is to freeze plasma for transport; however, this assumes that frozen plasma samples will give comparable results to fresh ones. We tested this assumption using plasma samples from three species of birds: chickens (Gallus gallus), ash-throated flycatchers (Myiarchus cinerascens), and western bluebirds (Sialia mexicana). Chicken plasma samples lost most or all of their bacterial killing ability after freezing. This did not happen in flycatchers and bluebirds; however, frozen plasma did not produce results comparable to those obtained using fresh plasma. We caution researchers using the BKA to use fresh samples whenever possible, and to validate the use of frozen samples on a species-by-species basis. Copyright © 2015 Elsevier Inc. All rights reserved.

  18. Bacteria-killing ability of fresh blood plasma compared to frozen blood plasma

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Jacobs, Anne C.; Fair, Jeanne Marie

    In recent years, the bacteria-killing assay (BKA) has become a popular technique among ecoimmunologists. New variations of that assay allow researchers to use smaller volumes of blood, an important consideration for those working on small-bodied animals. However, this version of the assay requires access to a lab with a nanodrop spectrophotometer, something that may not be available in the field. One possible solution is to freeze plasma for transport; however, this assumes that frozen plasma samples will give comparable results to fresh ones. Here, we tested this assumption using plasma samples from three species of birds: chickens (Gallus gallus), ash-throatedmore » flycatchers (Myiarchus cinerascens), and western bluebirds (Sialia mexicana). Chicken plasma samples lost most or all of their bacterial killing ability after freezing. This did not happen in flycatchers and bluebirds; however, frozen plasma did not produce results comparable to those obtained using fresh plasma. Finally, we caution researchers using the BKA to use fresh samples whenever possible, and to validate the use of frozen samples on a species-by-species basis.« less

  19. Soil Sample Dissolution Development by Ultrawave Digester, Followed by Isotopic Separation and Analysis

    DTIC Science & Technology

    2017-01-09

    uranium, americium, and thorium were analyzed, along with other transition and rare earth metals, utilizing inductively coupled plasma- mass spectrometry...inductively coupled plasma- mass spectrometry and/or alpha spectrometry, following digestion. For validation of the microwave protocol, radioactive... actinide elements. HF is a hazardous acid to work with and it is highly toxic. In this evaluation and validation, the actinides are of particular

  20. Quantitative determination of galantamine in human plasma by sensitive liquid chromatography-tandem mass spectrometry using loratadine as an internal standard.

    PubMed

    Nirogi, Ramakrishna V S; Kandikere, Vishwottam N; Mudigonda, Koteshwara; Maurya, Santosh

    2007-02-01

    A simple, rapid, sensitive, and selective liquid chromatography-tandem mass spectrometry method is developed and validated for the quantitation of galantamine, an acetylcholinesterase inhibitor in human plasma, using a commercially available compound, loratadine, as the internal standard. Following liquid-liquid extraction, the analytes are separated using an isocratic mobile phase on a reverse-phase C18 column and analyzed by mass spectrometry in the multiple reaction monitoring mode using the respective (M+H)+ ions, m/z 288 to 213 for galantamine and m/z 383 and 337 for the internal standard. The assay exhibit a linear dynamic range of 0.5-100 ng/mL for galantamine in human plasma. The lower limit of quantitation is 0.5 ng/mL, with a relative standard deviation of less than 8%. Acceptable precision and accuracy are obtained for concentrations over the standard curve range. A run time of 2.5 min for each sample makes it possible to analyze more than 400 human plasma samples per day. The validated method is successfully used to analyze human plasma samples for application in pharmacokinetic, bioavailability, or bioequivalence studies.

  1. Validated Method for the Quantification of Baclofen in Human Plasma Using Solid-Phase Extraction and Liquid Chromatography–Tandem Mass Spectrometry

    PubMed Central

    Nahar, Limon Khatun; Cordero, Rosa Elena; Nutt, David; Lingford-Hughes, Anne; Turton, Samuel; Durant, Claire; Wilson, Sue; Paterson, Sue

    2016-01-01

    Abstract A highly sensitive and fully validated method was developed for the quantification of baclofen in human plasma. After adjusting the pH of the plasma samples using a phosphate buffer solution (pH 4), baclofen was purified using mixed mode (C8/cation exchange) solid-phase extraction (SPE) cartridges. Endogenous water-soluble compounds and lipids were removed from the cartridges before the samples were eluted and concentrated. The samples were analyzed using triple-quadrupole liquid chromatography–tandem mass spectrometry (LC–MS-MS) with triggered dynamic multiple reaction monitoring mode for simultaneous quantification and confirmation. The assay was linear from 25 to 1,000 ng/mL (r2 > 0.999; n = 6). Intraday (n = 6) and interday (n = 15) imprecisions (% relative standard deviation) were <5%, and the average recovery was 30%. The limit of detection of the method was 5 ng/mL, and the limit of quantification was 25 ng/mL. Plasma samples from healthy male volunteers (n = 9, median age: 22) given two single oral doses of baclofen (10 and 60 mg) on nonconsecutive days were analyzed to demonstrate method applicability. PMID:26538544

  2. Dried Blood Spot Methodology in Combination With Liquid Chromatography/Tandem Mass Spectrometry Facilitates the Monitoring of Teriflunomide

    PubMed Central

    Lunven, Catherine; Turpault, Sandrine; Beyer, Yann-Joel; O'Brien, Amy; Delfolie, Astrid; Boyanova, Neli; Sanderink, Ger-Jan; Baldinetti, Francesca

    2016-01-01

    Background: Teriflunomide, a once-daily oral immunomodulator approved for treatment of relapsing-remitting multiple sclerosis, is eliminated slowly from plasma. If necessary to rapidly lower plasma concentrations of teriflunomide, an accelerated elimination procedure using cholestyramine or activated charcoal may be used. The current bioanalytical assay for determination of plasma teriflunomide concentration requires laboratory facilities for blood centrifugation and plasma storage. An alternative method, with potential for greater convenience, is dried blood spot (DBS) methodology. Analytical and clinical validations are required to switch from plasma to DBS (finger-prick sampling) methodology. Methods: Using blood samples from healthy subjects, an LC-MS/MS assay method for quantification of teriflunomide in DBS over a range of 0.01–10 mcg/mL was developed and validated for specificity, selectivity, accuracy, precision, reproducibility, and stability. Results were compared with those from the current plasma assay for determination of plasma teriflunomide concentration. Results: Method was specific and selective relative to endogenous compounds, with process efficiency ∼88%, and no matrix effect. Inaccuracy and imprecision for intraday and interday analyses were <15% at all concentrations tested. Quantification of teriflunomide in DBS assay was not affected by blood deposit volume and punch position within spot, and hematocrit level had a limited but acceptable effect on measurement accuracy. Teriflunomide was stable for at least 4 months at room temperature, and for at least 24 hours at 37°C with and without 95% relative humidity, to cover sampling, drying, and shipment conditions in the field. The correlation between DBS and plasma concentrations (R2 = 0.97), with an average blood to plasma ratio of 0.59, was concentration independent and constant over time. Conclusions: DBS sampling is a simple and practical method for monitoring teriflunomide concentrations. PMID:27015245

  3. Development and validation of a sensitive liquid chromatographic-tandem mass spectrometric method for the simultaneous analysis of granisetron and 7-hydroxy granisetron in human plasma and urine samples: application in a clinical pharmacokinetic study in pregnant subject.

    PubMed

    Zhao, Yang; Chen, Hui-Jun; Caritis, Steve; Venkataramanan, Raman

    2016-02-01

    A liquid chromatography-tandem mass spectrometric method for the quantification of granisetron and its major metabolite, 7-hydroxy granisetron in human plasma and urine samples was developed and validated. Respective stable isotopically labeled granisetron and 7-hydroxy granisetron were used as internal standards (IS). Chromatography was performed using an Xselect HSS T3 analytical column with a mobile phase of 20% acetonitrile in water (containing 0.2 mM ammonium formate and 0.14% formic acid, pH 4) delivered in an isocratic mode. Tandem mass spectrometry operating in positive electrospray ionization mode with multiple reaction monitoring was used for quantification. The standard curves were linear in the concentration ranges of 0.5-100 ng/mL for granisetron and 0.1-100 ng/mL for 7-hydroxy granisetron in human plasma samples, and 2-2000 ng/mL for granisetron and 2-1000 ng/mL for 7-hydroxy granisetron in human urine samples, respectively. The accuracies were >85% and the precision as determined by the coefficient of variations was <10%. No significant matrix effects were observed for granisetron or 7-hydroxy granisetron in either plasma or urine samples. Granisetron was stable under various storage and experimental conditions. This validated method was successfully applied to a pharmacokinetic study after intravenous administration of 1 mg granisetron to a pregnant subject. Copyright © 2015 John Wiley & Sons, Ltd.

  4. Determination of molindone enantiomers in human plasma by high-performance liquid chromatography-tandem mass spectrometry using macrocyclic antibiotic chiral stationary phases.

    PubMed

    Jiang, Hongliang; Li, Yinghe; Pelzer, Mary; Cannon, Michelle J; Randlett, Christopher; Junga, Heiko; Jiang, Xiangyu; Ji, Qin C

    2008-05-30

    A sensitive and selective bioanalytical assay was developed and validated for the determination of enantiomeric molindone in human plasma using high-performance liquid chromatography-tandem mass spectrometry along with supported liquid extraction procedures. The chiral separation was evaluated and optimized on macrocyclic antibiotic type chiral stationary phases (CSPs) based on teicoplanin aglycone (Chirobiotic TAG) in polar organic, polar ionic, and reversed-phase mode chromatography, respectively. Complete baseline separation was achieved on a Chirobiotic TAG column under isocratic condition in reversed-phase chromatography. The method validation was conducted using a Chirobiotic TAG column (100 mm x 2.1 mm) over the curve range 0.100-100 ng/ml for each molindone enantiomer using 0.0500 ml of plasma sample. The flow rate was 0.8 ml/min and the total run time was 9 min. Supported liquid extraction in a 96-well plate format was used for sample preparation. Parameters including recovery, matrix effect, linearity, sensitivity, specificity, carryover, precision, accuracy, dilution integrity, and stability were evaluated. The intra- and inter-day precision and accuracy of the quality control samples at low, medium, and high concentration levels were RSD

  5. Standard Specimen Reference Set: Colon — EDRN Public Portal

    Cancer.gov

    The Early Detection Research Network, Great Lakes-New England Clinical, Epidemiological and Validation Center (GLNE CVC) announces the availability of serum, plasma and urine samples for the early detection for colon cancer and validation studies.

  6. A novel LC-MS/MS method for the simultaneous quantification of topiramate and its main metabolites in human plasma.

    PubMed

    Milosheska, Daniela; Roškar, Robert

    2017-05-10

    The aim of the present report was to develop and validate simple, sensitive and reliable LC-MS/MS method for quantification of topiramate (TPM) and its main metabolites: 2,3-desisopropylidene TPM, 4,5-desisopropylidene TPM, 10-OH TPM and 9-OH TPM in human plasma samples. The most abundant metabolite 2,3-desisopropylidene TPM was isolated from patients urine, characterized and afterwards used as an authentic standard for method development and validation. Sample preparation method employs 100μL of plasma sample and liquid-liquid extraction with a mixture of ethyl acetate and diethyl ether as extraction solvent. Chromatographic separation was achieved on a 1290 Infinity UHPLC coupled to 6460 Triple Quad Mass Spectrometer operated in negative MRM mode using Kinetex C18 column (50×2.1mm, 2.6μm) by gradient elution using water and methanol as a mobile phase and stable isotope labeled TPM as internal standard. The method showed to be selective, accurate, precise and linear over the concentration ranges of 0.10-20μg/mL for TPM, 0.01-2.0μg/mL for 2,3-desisopropylidene TPM, and 0.001-0.200μg/mL for 4,5-desisopropylidene TPM, 10-OH TPM and 9-OH TPM. The described method is the first fully validated method capable of simultaneous determination of TPM and its main metabolites in plasma over the selected analytical range. The suitability of the method was successfully demonstrated by the quantification of all analytes in plasma samples of patients with epilepsy and can be considered as reliable analytical tool for future investigations of the TPM metabolism. Copyright © 2017 Elsevier B.V. All rights reserved.

  7. Development of water-phase derivatization followed by solid-phase microextraction and gas chromatography/mass spectrometry for fast determination of valproic acid in human plasma.

    PubMed

    Deng, Chunhui; Li, Ning; Ji, Jie; Yang, Bei; Duan, Gengli; Zhang, Xiangmin

    2006-01-01

    In this study, a simple, rapid, and sensitive method was developed and validated for the quantification of valproic acid (VPA), an antiepileptic drug, in human plasma, which was based on water-phase derivatization followed by headspace solid-phase microextraction (HS-SPME) and gas chromatography/mass spectrometry (GC/MS). In the proposed method, VPA in plasma was rapidly derivatized with a mixture of isobutyl chloroformate, ethanol and pyridine under mild conditions (room temperature, aqueous medium), and the VPA ethyl ester formed was headspace-extracted and simultaneously concentrated using the SPME technique. Finally, the analyte extracted on SPME fiber was analyzed by GC/MS. The experimental parameters and method validations were studied. The optimal conditions were obtained: PDMS fiber, stirring rate of 1100 rpm, sample temperature of 80 degrees C, extraction time of 20 min, NaCl concentration of 30%. The proposed method had a limit of quantification (0.3 microg/mL), good recovery (89-97%) and precision (RSD value less than 10%). Because the proposed method combined a rapid water-phase derivatization with a fast, simple and solvent-free sample extraction and concentration technique of SPME, the sample preparation time was less than 25 min. This much shortens the whole analysis time of VPA in plasma. The validated method has been successfully used to analyze VPA in human plasma samples for application in pharmacokinetic studies. All these results show that water-phase derivatization followed by HS-SPME and GC/MS is an alternative and powerful method for fast determination of VPA in biological fluids. Copyright 2006 John Wiley & Sons, Ltd.

  8. HPLC-electrospray mass spectrometric assay for the determination of (R,R)-fenoterol in rat plasma.

    PubMed

    Siluk, Danuta; Kim, Hee Seung; Cole, Tyler; Wainer, Irving W

    2008-11-04

    A fast and specific liquid chromatography-mass spectrometry method for the determination of (R,R)-fenoterol ((R,R)-Fen) in rat plasma has been developed and validated. (R,R)-Fen was extracted from 125 microl of plasma using solid phase extraction and analyzed on Atlantis HILIC Silica 3 microm column. The mobile phase was composed of acetonitrile:ammonium acetate (pH 4.1; 20mM) (85:15, v/v), at a flow rate of 0.2 ml/min. The lower limit of detection (LLOD) was 2 ng/ml . The procedure was validated and applied to the analysis of plasma samples from rats previously administered (R,R)-Fen in an intravenous bolus.

  9. Development and Validation of an Inductively Coupled Plasma Mass Spectrometry (ICP-MS) Method for Quantitative Analysis of Platinum in Plasma, Urine, and Tissues.

    PubMed

    Zhang, Ti; Cai, Shuang; Forrest, Wai Chee; Mohr, Eva; Yang, Qiuhong; Forrest, M Laird

    2016-09-01

    Cisplatin, a platinum chemotherapeutic, is one of the most commonly used chemotherapeutic agents for many solid tumors. In this work, we developed and validated an inductively coupled plasma mass spectrometry (ICP-MS) method for quantitative determination of platinum levels in rat urine, plasma, and tissue matrices including liver, brain, lungs, kidney, muscle, heart, spleen, bladder, and lymph nodes. The tissues were processed using a microwave accelerated reaction system (MARS) system prior to analysis on an Agilent 7500 ICP-MS. According to the Food and Drug Administration guidance for industry, bioanalytical validation parameters of the method, such as selectivity, accuracy, precision, recovery, and stability were evaluated in rat biological samples. Our data suggested that the method was selective for platinum without interferences caused by other presenting elements, and the lower limit of quantification was 0.5 ppb. The accuracy and precision of the method were within 15% variation and the recoveries of platinum for all tissue matrices examined were determined to be 85-115% of the theoretical values. The stability of the platinum-containing solutions, including calibration standards, stock solutions, and processed samples in rat biological matrices was investigated. Results indicated that the samples were stable after three cycles of freeze-thaw and for up to three months. © The Author(s) 2016.

  10. Development and Validation of an Inductively Coupled Plasma Mass Spectrometry (ICP-MS) Method for Quantitative Analysis of Platinum in Plasma, Urine, and Tissues

    PubMed Central

    Zhang, Ti; Cai, Shuang; Forrest, Wai Chee; Mohr, Eva; Yang, Qiuhong; Forrest, M. Laird

    2016-01-01

    Cisplatin, a platinum chemotherapeutic, is one of the most commonly used chemotherapeutic agents for many solid tumors. In this work, we developed and validated an inductively coupled plasma mass spectrometry (ICP-MS) method for quantitative determination of platinum levels in rat urine, plasma, and tissue matrices including liver, brain, lungs, kidney, muscle, heart, spleen, bladder, and lymph nodes. The tissues were processed using a microwave accelerated reaction system (MARS) system prior to analysis on an Agilent 7500 ICP-MS. According to the Food and Drug Administration guidance for industry, bioanalytical validation parameters of the method, such as selectivity, accuracy, precision, recovery, and stability were evaluated in rat biological samples. Our data suggested that the method was selective for platinum without interferences caused by other presenting elements, and the lower limit of quantification was 0.5 ppb. The accuracy and precision of the method were within 15% variation and the recoveries of platinum for all tissue matrices examined were determined to be 85–115% of the theoretical values. The stability of the platinum-containing solutions, including calibration standards, stock solutions, and processed samples in rat biological matrices was investigated. Results indicated that the samples were stable after three cycles of freeze–thaw and for up to three months. PMID:27527103

  11. Validation and Clinical Evaluation of a Novel Method To Measure Miltefosine in Leishmaniasis Patients Using Dried Blood Spot Sample Collection

    PubMed Central

    Rosing, H.; Hillebrand, M. J. X.; Blesson, S.; Mengesha, B.; Diro, E.; Hailu, A.; Schellens, J. H. M.; Beijnen, J. H.

    2016-01-01

    To facilitate future pharmacokinetic studies of combination treatments against leishmaniasis in remote regions in which the disease is endemic, a simple cheap sampling method is required for miltefosine quantification. The aims of this study were to validate a liquid chromatography-tandem mass spectrometry method to quantify miltefosine in dried blood spot (DBS) samples and to validate its use with Ethiopian patients with visceral leishmaniasis (VL). Since hematocrit (Ht) levels are typically severely decreased in VL patients, returning to normal during treatment, the method was evaluated over a range of clinically relevant Ht values. Miltefosine was extracted from DBS samples using a simple method of pretreatment with methanol, resulting in >97% recovery. The method was validated over a calibration range of 10 to 2,000 ng/ml, and accuracy and precision were within ±11.2% and ≤7.0% (≤19.1% at the lower limit of quantification), respectively. The method was accurate and precise for blood spot volumes between 10 and 30 μl and for Ht levels of 20 to 35%, although a linear effect of Ht levels on miltefosine quantification was observed in the bioanalytical validation. DBS samples were stable for at least 162 days at 37°C. Clinical validation of the method using paired DBS and plasma samples from 16 VL patients showed a median observed DBS/plasma miltefosine concentration ratio of 0.99, with good correlation (Pearson's r = 0.946). Correcting for patient-specific Ht levels did not further improve the concordance between the sampling methods. This successfully validated method to quantify miltefosine in DBS samples was demonstrated to be a valid and practical alternative to venous blood sampling that can be applied in future miltefosine pharmacokinetic studies with leishmaniasis patients, without Ht correction. PMID:26787691

  12. Development and validation of a high-performance liquid chromatography method for the quantification of talazoparib in rat plasma: Application to plasma protein binding studies.

    PubMed

    Hidau, Mahendra Kumar; Kolluru, Srikanth; Palakurthi, Srinath

    2018-02-01

    A sensitive and selective RP-HPLC method has been developed and validated for the quantification of a highly potent poly ADP ribose polymerase inhibitor talazoparib (TZP) in rat plasma. Chromatographic separation was performed with isocratic elution method. Absorbance for TZP was measured with a UV detector (SPD-20A UV-vis) at a λ max of 227 nm. Protein precipitation was used to extract the drug from plasma samples using methanol-acetonitrile (65:35) as the precipitating solvent. The method proved to be sensitive and reproducible over a 100-2000 ng/mL linearity range with a lower limit of quantification (LLQC) of 100 ng/mL. TZP recovery was found to be >85%. Following analytical method development and validation, it was successfully employed to determine the plasma protein binding of TZP. TZP has a high level of protein binding in rat plasma (95.76 ± 0.38%) as determined by dialysis method. Copyright © 2017 John Wiley & Sons, Ltd.

  13. Validation of a liquid chromatography-triple quadrupole mass spectrometric method for the determination of 5-nitro-5'-hydroxy-indirubin-3'-oxime (AGM-130) in human plasma and its application to microdose clinical trial.

    PubMed

    Park, Min-Ho; Lee, Yun Young; Cho, Kyung Hee; La, Sookie; Lee, Hee Joo; Yim, Dong-Seok; Ban, Sooho; Park, Moon-Young; Kim, Yong-Chul; Kim, Yoon-Gyoon; Shin, Young G

    2016-03-01

    A liquid chromatography-triple quadrupole mass spectrometric (LC-MS/MS) method was developed and validated for the determination of 5-nitro-5'-hydroxy-indirubin-3'-oxime (AGM-130) in human plasma to support a microdose clinical trial. The method consisted of a liquid-liquid extraction for sample preparation and LC-MS/MS analysis in the positive ion mode using TurboIonSpray(TM) for analysis. d3 -AGM-130 was used as the internal standard. A linear regression (weighted 1/concentration) was used to fit calibration curves over the concentration range of 10-2000 pg/mL for AGM-130. There were no endogenous interference components in the blank human plasma tested. The accuracy at the lower limit of quantitation was 96.6% with a precision (coefficient of variation, CV) of 4.4%. For quality control samples at 30, 160 and 1600 pg/mL, the between run CV was ≤5.0 %. Between-run accuracy ranged from 98.1 to 101.0%. AGM-130 was stable in 50% acetonitrile for 168 h at 4°C and 6 h at room temperature. AGM-130 was also stable in human plasma at room temperature for 6 h and through three freeze-thaw cycles. The variability of selected samples for the incurred sample reanalysis was ≤12.7% when compared with the original sample concentrations. This validated LC-MS/MS method for determination of AGM-130 was used to support a phase 0 microdose clinical trial. Copyright © 2015 John Wiley & Sons, Ltd.

  14. A validated UPLC-MS/MS method for the analysis of linezolid and a novel oxazolidinone derivative (PH027) in plasma and its application to tissue distribution study in rabbits.

    PubMed

    Hedaya, Mohsen A; Thomas, Vidhya; Abdel-Hamid, Mohamed E; Kehinde, Elijah O; Phillips, Oludotun A

    2017-01-01

    Linezolid is the first approved oxazolidinone antibacterial agent, whereas PH027 is a novel compound of the same class that exhibits good in vitro antibacterial activity. The objective of this study was to develop an UPLC-MS/MS assay for the analysis of linezolid and PH027 in plasma and to apply the method for comparative pharmacokinetic and tissue distribution studies of both compounds. Plasma samples and calibrators were extracted with diethyl ether after addition of the internal standard solution. After evaporation of the ether layer, the residue was reconstituted in mobile phase and injected into UPLC-MS/MS. The mobile phase consisted of 2mM ammonium acetate buffer solution and acetonitrile (70:30) at a flow rate of 0.2ml/min. Separation was achieved using UPLC BEH C 18 column, and quantitative determination of the analytes was performed using multiple-reaction monitoring (MRM) scanning mode. The method was validated by analyzing quality control tissue homogenate samples, and was applied to analyze tissue homogenate samples obtained following IV injections of linezolid and PH027 in rabbits. The developed UPLC-MS/MS method was linear in the concentration range of 50-5000ng/ml. Validation of the method proved that the method's precision, selectivity and stability were all within the acceptable limits. Linezolid and PH027 concentrations were accurately determined in the quality control tissue homogenate samples, and analysis of samples obtained following IV administration of the two compounds showed that the tissue to plasma concentration ratio of PH027 was higher than that of linezolid probably due to its higher lipophilicity. The developed UPLC-MS/MS method for the analysis of linezolid and PH027 in rabbit's plasma can accurately determine the concentrations of these compounds in different tissues. Copyright © 2016 Elsevier B.V. All rights reserved.

  15. Validated Method for the Quantification of Baclofen in Human Plasma Using Solid-Phase Extraction and Liquid Chromatography-Tandem Mass Spectrometry.

    PubMed

    Nahar, Limon Khatun; Cordero, Rosa Elena; Nutt, David; Lingford-Hughes, Anne; Turton, Samuel; Durant, Claire; Wilson, Sue; Paterson, Sue

    2016-03-01

    A highly sensitive and fully validated method was developed for the quantification of baclofen in human plasma. After adjusting the pH of the plasma samples using a phosphate buffer solution (pH 4), baclofen was purified using mixed mode (C8/cation exchange) solid-phase extraction (SPE) cartridges. Endogenous water-soluble compounds and lipids were removed from the cartridges before the samples were eluted and concentrated. The samples were analyzed using triple-quadrupole liquid chromatography-tandem mass spectrometry (LC-MS-MS) with triggered dynamic multiple reaction monitoring mode for simultaneous quantification and confirmation. The assay was linear from 25 to 1,000 ng/mL (r(2) > 0.999; n = 6). Intraday (n = 6) and interday (n = 15) imprecisions (% relative standard deviation) were <5%, and the average recovery was 30%. The limit of detection of the method was 5 ng/mL, and the limit of quantification was 25 ng/mL. Plasma samples from healthy male volunteers (n = 9, median age: 22) given two single oral doses of baclofen (10 and 60 mg) on nonconsecutive days were analyzed to demonstrate method applicability. © The Author 2015. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.

  16. A Simple Method to Quantitate IP-10 in Dried Blood and Plasma Spots

    PubMed Central

    Aabye, Martine G.; Eugen-Olsen, Jesper; Werlinrud, Anne Marie; Holm, Line Lindebo; Tuuminen, Tamara; Ravn, Pernille; Ruhwald, Morten

    2012-01-01

    Background Antigen specific release of IP-10 is an established marker for infection with M.tuberculosis. Compared to IFN-γ, IP-10 is released in 100-fold higher concentrations enabling the development of novel assays for detection. Dried blood spots are a convenient sample for high throughput newborn screening. Aim To develop a robust and sensitive ELISA-based assay for IP-10 detection in plasma, dried blood spots (DBS) and dried plasma spots (DPS); to validate the ELISA in clinically relevant samples; and to assess the performance of the assay for detection of Cytomegalovirus (CMV) and M.tuberculosis specific immune responses. Method We raised mice and rat monoclonal antibodies against human IP-10 and developed an ELISA. The assay was validated and applied to the detection of CMV and M.tuberculosis specific responses in 18 patients with immune reactivity towards M.tuberculosis and 32 healthy controls of which 22 had immune reactivity towards CMV and none towards M.tuberculosis. We compared the performance of this new assay to IFN-γ. Results The ELISA was reliable for IP-10 detection in both plasma and filter paper samples. The linear range of the ELISA was 2.5–600 pg/ml. IFN-γ was not readily detectable in DPS samples. IP-10 was stabile in filter paper samples for at least 4 weeks at 37°C. The correlation between IP-10 detected in plasma, DPS and DBS samples was excellent (r2>0.97). Conclusions This newly developed assay is reliable for IP-10 quantification in plasma, DBS and DPS samples from antigen stimulated and non-stimulated whole blood. The filter paper assays enable easy sample acquisition and transport at ambient temperature e.g. via the postal system. The system can potentially simplify diagnostic assays for M.tuberculosis and CMV infection. PMID:22761744

  17. Development and validation of a sensitive LC/MS/MS method for the simultaneous determination of naloxone and its metabolites in mouse plasma.

    PubMed

    Jiang, Hongliang; Wang, Yurong; Shet, Manjunath S; Zhang, Yang; Zenke, Duane; Fast, Douglas M

    2011-09-01

    A rapid, specific, and reliable LC-MS/MS based bioanalytical method was developed and validated for the simultaneous determination of naloxone (NLX) and its two metabolites, 6β-naloxol (NLL) and naloxone-3β-D-glucuronide (NLG) in mouse plasma. The optimal chromatographic behavior of these analytes was achieved on an Aquasil C18 column (50 mm × 2.1 mm, 5 μm) using reversed phase chromatography. The total LC analysis time per injection was 2.5 min with a flow rate of 1.0 mL/min with gradient elution. Sample preparation via protein precipitation with acetonitrile in a 96-well format was applied for analyses of these analytes. The analytes were monitored by electrospray ionization in positive ion multiple reaction monitoring (MRM) mode. Modification of collision energy besides chromatographic separation was applied to further eliminate interference peaks for NLL and NLG. The method validation was conducted over the curve range of 0.200/0.400/0.500 to 100/200/250 ng/mL for NLX/NLL/NLG, respectively, using 0.0250 mL of plasma sample. The intra- and inter-day precision and accuracy of the quality control samples at low, medium, and high concentration levels showed ≤ 6.5% relative standard deviation (RSD) and -8.3 to -2.5% relative error (RE). The method was successfully applied to determine the concentrations of NLX, NLL, and NLG in incurred mouse plasma samples. Copyright © 2011 Elsevier B.V. All rights reserved.

  18. Alemtuzumab: validation of a sensitive and simple enzyme-linked immunosorbent assay.

    PubMed

    Jilani, Iman; Keating, Michael; Giles, Francis J; O'Brien, Susan; Kantarjian, Hagop M; Albitar, Maher

    2004-12-01

    Alemtuzumab (MabCampath) is a humanized rat monoclonal antibody that targets the CD52 antigen. It has been approved for the treatment of patients with resistant chronic lymphocytic leukaemia (CLL). Measuring plasma/serum levels of alemtuzumab is important for optimizing the dosing and scheduling of therapy; however, current assays in serum or plasma, based on the capture of alemtuzumab using CD52, are complicated and difficult to adapt for high throughput testing. We developed a simple sandwich enzyme-linked immunosorbent assay (ELISA) to measure alemtuzumab that takes advantage of the remaining rat sequence in alemtuzumab. Using specific anti-rat immunoglobulin (Ig) antibodies (absorbed against human Ig), alemtuzumab levels were measured in the serum and plasma of patients treated with alemtuzumab. Levels were similar between plasma and serum samples, in fresh samples and samples stored at 4 degrees C for 24 h, but were significantly lower in samples stored at room temperature for 24h. The assay was successfully used to determine serum alemtuzumab pre- and post-treatment. This assay is simple and adaptable for high throughput testing, with a limit of detection of 0.05 microg/ml and a coefficient of variation of +/-12.5%. No false positivity was observed in >200 samples tested. This validated assay should help optimize the dosing and scheduling of alemtuzumab therapy. The underlying principles are also applicable to the measurement of other humanized antibodies using an appropriate anti-Ig.

  19. HPLC–electrospray mass spectrometric assay for the determination of (R,R)-fenoterol in rat plasma

    PubMed Central

    Siluk, Danuta; Kim, Hee Seung; Cole, Tyler; Wainer, Irving W.

    2008-01-01

    A fast and specific liquid chromatography–mass spectrometry method for the determination of (R,R)-fenoterol ((R,R)-Fen) in rat plasma has been developed and validated. (R,R)-Fen was extracted from 125 µl of plasma using solid phase extraction and analyzed on Atlantis HILIC Silica 3 µm column. The mobile phase was composed of acetonitrile:ammonium acetate (pH 4.1; 20 mM) (85:15, v/v), at a flow rate of 0.2 ml/min. The lower limit of detection (LLOD) was 2 ng/ml . The procedure was validated and applied to the analysis of plasma samples from rats previously administered (R,R)-Fen in an intravenous bolus. PMID:18617349

  20. A liquid chromatography/tandem mass spectrometry assay for the analysis of atomoxetine in human plasma and in vitro cellular samples

    PubMed Central

    Appel, David I.; Brinda, Bryan; Markowitz, John S.; Newcorn, Jeffrey H.; Zhu, Hao-Jie

    2012-01-01

    A simple, rapid and sensitive method for quantification of atomoxetine by liquid chromatography- tandem mass spectrometry (LC-MS/MS) was developed. This assay represents the first LC-MS/MS quantification method for atomoxetine utilizing electrospray ionization. Deuterated atomoxetine (d3-atomoxetine) was adopted as the internal standard. Direct protein precipitation was utilized for sample preparation. This method was validated for both human plasma and in vitro cellular samples. The lower limit of quantification was 3 ng/ml and 10 nM for human plasma and cellular samples, respectively. The calibration curves were linear within the ranges of 3 ng/ml to 900 ng/ml and 10 nM to 10 μM for human plasma and cellular samples, respectively (r2 > 0.999). The intra- and inter-day assay accuracy and precision were evaluated using quality control samples at 3 different concentrations in both human plasma and cellular lysate. Sample run stability, assay selectivity, matrix effect, and recovery were also successfully demonstrated. The present assay is superior to previously published LC-MS and LC-MS/MS methods in terms of sensitivity or the simplicity of sample preparation. This assay is applicable to the analysis of atomoxetine in both human plasma and in vitro cellular samples. PMID:22275222

  1. Fully automated method for the liquid chromatographic determination of cyproterone acetate in plasma using restricted access material for sample pre-treatment.

    PubMed

    Christiaens, B; Chiap, P; Rbeida, O; Cello, D; Crommen, J; Hubert, Ph

    2003-09-25

    A new fully automated method for the quantitative analysis of an antiandrogenic substance, cyproterone acetate (CPA), in plasma samples has been developed using on-line solid-phase extraction (SPE) prior to the determination by reversed-phase liquid chromatography (LC). The automated method was based on the use of a precolumn packed with an internal-surface reversed-phase packing material (LiChrospher RP-4 ADS) for sample clean-up coupled to LC analysis on an octadecyl stationary phase using a column-switching system. A 200-microL volume of plasma sample was injected directly on the precolumn packed with restricted access material using a mixture of water-acetonitrile (90:10, v/v) as washing liquid. The analyte was then eluted in the back-flush mode with the LC mobile phase which consisted of a mixture of phosphate buffer, pH 7.0-acetonitrile (54:46, v/v). The elution profiles of CPA and blank plasma samples on the precolumn and the time needed for analyte transfer from the precolumn to the analytical column were determined. Different compositions of washing liquid and mobile phase were tested to reduce the interference of plasma endogenous components. UV detection was achieved at 280 nm. Finally, the developed method was validated using a new approach, namely the application of the accuracy profile based on the interval confidence at 90% of the total measurement error (bias+standard deviation). The limit of quantification of cyproterone acetate in plasma was determined at 15 ng mL(-1). The validated method should be applicable to the determination of CPA in patients treated by at least 50 mg day(-1).

  2. A rapid and sensitive LC-MS/MS method for the determination of Pulsatilla saponin D in rat plasma and its application in a rat pharmacokinetic and bioavailability study.

    PubMed

    Ouyang, Hui; Guo, Yicheng; He, Mingzhen; Zhang, Jinlian; Huang, Xiaofang; Zhou, Xin; Jiang, Hongliang; Feng, Yulin; Yang, Shilin

    2015-03-01

    A simple, sensitive and specific liquid chromatography-tandem mass spectrometry method was developed and validated for the determination of Pulsatilla saponin D, a potential antitumor constituent isolated from Pulsatilla chinensis in rat plasma. Rat plasma samples were pretreated by protein precipitation with methanol. The method validation was performed in accordance with US Food and Drug Administration guidelines and the results met the acceptance criteria. The method was successfully applied to assess the pharmacokinetics and oral bioavailability of Pulsatilla saponin D in rats. Copyright © 2014 John Wiley & Sons, Ltd.

  3. Comparison of the quantification of acetaminophen in plasma, cerebrospinal fluid and dried blood spots using high-performance liquid chromatography-tandem mass spectrometry

    PubMed Central

    Taylor, Rachel R.; Hoffman, Keith L.; Schniedewind, Björn; Clavijo, Claudia; Galinkin, Jeffrey L.; Christians, Uwe

    2013-01-01

    Acetaminophen (paracetamol, N-(4-hydroxyphenyl) acetamide) is one of the most commonly prescribed drugs for the management of pain in children. Quantification of acetaminophen in pre-term and term neonates and small children requires the availability of highly sensitive assays in small volume blood samples. We developed and validated an LC-MS/MS assay for the quantification of acetaminophen in human plasma, cerebro-spinal fluid (CSF) and dried blood spots (DBS). Reconstitution in water (DBS only) and addition of a protein precipitation solution containing the deuterated internal standard were the only manual steps. Extracted samples were analyzed on a Kinetex 2.6 μm PFP column using an acetonitrile/formic acid gradient. The analytes were detected in the positive multiple reaction mode. Alternatively, DBS were automatically processed using direct desorption in a sample card and preparation (SCAP) robotic autosampler in combination with online extraction. The range of reliable response in plasma and CSF was 3.05-20,000 ng/ml (r2 > 0.99) and 27.4-20,000 ng/ml (r2 > 0.99) for DBS (manual extraction and automated direct desorption). Inter-day accuracy was always within 85-115% and inter-day precision for plasma, CSF and manually extracted DBS were less than 15%. Deming regression analysis comparing 167 matching pairs of plasma and DBS samples showed a correlation coefficient of 0.98. Bland Altman analysis indicated a 26.6% positive bias in DBS, most likely reflecting the blood: plasma distribution ratio of acetaminophen. DBS are a valid matrix for acetaminophen pharmacokinetic studies. PMID:23670126

  4. A Novel HPLC Method for the Concurrent Analysis and Quantitation of Seven Water-Soluble Vitamins in Biological Fluids (Plasma and Urine): A Validation Study and Application

    PubMed Central

    Grotzkyj Giorgi, Margherita; Howland, Kevin; Martin, Colin; Bonner, Adrian B.

    2012-01-01

    An HPLC method was developed and validated for the concurrent detection and quantitation of seven water-soluble vitamins (C, B1, B2, B5, B6, B9, B12) in biological matrices (plasma and urine). Separation was achieved at 30°C on a reversed-phase C18-A column using combined isocratic and linear gradient elution with a mobile phase consisting of 0.01% TFA aqueous and 100% methanol. Total run time was 35 minutes. Detection was performed with diode array set at 280 nm. Each vitamin was quantitatively determined at its maximum wavelength. Spectral comparison was used for peak identification in real samples (24 plasma and urine samples from abstinent alcohol-dependent males). Interday and intraday precision were <4% and <7%, respectively, for all vitamins. Recovery percentages ranged from 93% to 100%. PMID:22536136

  5. A novel HPLC method for the concurrent analysis and quantitation of seven water-soluble vitamins in biological fluids (plasma and urine): a validation study and application.

    PubMed

    Giorgi, Margherita Grotzkyj; Howland, Kevin; Martin, Colin; Bonner, Adrian B

    2012-01-01

    An HPLC method was developed and validated for the concurrent detection and quantitation of seven water-soluble vitamins (C, B(1), B(2), B(5), B(6), B(9), B(12)) in biological matrices (plasma and urine). Separation was achieved at 30°C on a reversed-phase C18-A column using combined isocratic and linear gradient elution with a mobile phase consisting of 0.01% TFA aqueous and 100% methanol. Total run time was 35 minutes. Detection was performed with diode array set at 280 nm. Each vitamin was quantitatively determined at its maximum wavelength. Spectral comparison was used for peak identification in real samples (24 plasma and urine samples from abstinent alcohol-dependent males). Interday and intraday precision were <4% and <7%, respectively, for all vitamins. Recovery percentages ranged from 93% to 100%.

  6. The validity and reproducibility of food-frequency questionnaire-based total antioxidant capacity estimates in Swedish women.

    PubMed

    Rautiainen, Susanne; Serafini, Mauro; Morgenstern, Ralf; Prior, Ronald L; Wolk, Alicja

    2008-05-01

    Total antioxidant capacity (TAC) provides an assessment of antioxidant activity and synergistic interactions of redox molecules in foods and plasma. We investigated the validity and reproducibility of food-frequency questionnaire (FFQ)-based TAC estimates assessed by oxygen radical absorbance capacity (ORAC), total radical-trapping antioxidant parameters (TRAP), and ferric-reducing antioxidant power (FRAP) food values. Validity and reproducibility were evaluated in 2 random samples from the Swedish Mammography Cohort. Validity was studied by comparing FFQ-based TAC estimates with one measurement of plasma TAC in 108 women (54-73-y-old dietary supplement nonusers). Reproducibility was studied in 300 women (56-75 y old, 50.7% dietary supplement nonusers) who completed 2 FFQs 1 y apart. Fruit and vegetables (mainly apples, pears, oranges, and berries) were the major contributors to FFQ-based ORAC (56.5%), TRAP (41.7%), and FRAP (38.0%) estimates. In the validity study, whole plasma ORAC was correlated (Pearson) with FFQ-based ORAC (r = 0.35), TRAP (r = 0.31), and FRAP (r = 0.28) estimates from fruit and vegetables. Correlations between lipophilic plasma ORAC and FFQ-based ORAC, TRAP, and FRAP estimates from fruit and vegetables were 0.41, 0.31, and 0.28, and correlations with plasma TRAP estimates were 0.31, 0.30, and 0.28, respectively. Hydrophilic plasma ORAC and plasma FRAP values did not correlate with FFQ-based TAC estimates. Reproducibility, assessed by intraclass correlations, was 0.60, 0.61, and 0.61 for FFQ-based ORAC, TRAP, and FRAP estimates, respectively, from fruit and vegetables. FFQ-based TAC values represent valid and reproducible estimates that may be used in nutritional epidemiology to assess antioxidant intake from foods. Further studies in other populations to confirm these results are needed.

  7. Analytical validation of a new point-of-care assay for serum amyloid A in horses.

    PubMed

    Schwartz, D; Pusterla, N; Jacobsen, S; Christopher, M M

    2018-01-17

    Serum amyloid A (SAA) is a major acute phase protein in horses. A new point-of-care (POC) test for SAA (Stablelab) is available, but studies evaluating its analytical accuracy are lacking. To evaluate the analytical performance of the SAA POC test by 1) determining linearity and precision, 2) comparing results in whole blood with those in serum or plasma, and 3) comparing POC results with those obtained using a previously validated turbidimetric immunoassay (TIA). Assay validation. Analytical validation of the POC test was done in accordance with American Society of Veterinary Clinical Pathology guidelines using residual equine serum/plasma and whole blood samples from the Clinical Pathology Laboratory at the University of California-Davis. A TIA was used as the reference method. We also evaluated the effect of haematocrit (HCT). The POC test was linear for SAA concentrations of up to at least 1000 μg/mL (r = 0.991). Intra-assay CVs were 13, 18 and 15% at high (782 μg/mL), intermediate (116 μg/mL) and low (64 μg/mL) concentrations. Inter-assay (inter-batch) CVs were 45, 14 and 15% at high (1372 μg/mL), intermediate (140 μg/mL) and low (56 μg/mL) concentrations. SAA results in whole blood were significantly lower than those in serum/plasma (P = 0.0002), but were positively correlated (r = 0.908) and not affected by HCT (P = 0.261); proportional negative bias was observed in samples with SAA>500 μg/mL. The difference between methods exceeded the 95% confidence interval of the combined imprecision of both methods (15%). Analytical validation could not be performed in whole blood, the sample most likely to be used stall side. The POC test has acceptable accuracy and precision in equine serum/plasma with SAA concentrations of up to at least 1000 μg/mL. Low inter-batch precision at high concentrations may affect serial measurements, and the use of the same test batch and sample type (serum/plasma or whole blood) is recommended. Comparison of results between the POC test and the TIA is not recommended. © 2018 EVJ Ltd.

  8. Demonstration/Validation of the Snap Sampler Passive Groundwater Sampling Device at the Former McClellan Air Force Base

    DTIC Science & Technology

    2011-02-01

    and Development Center Fe Iron gpd Gallons per Day HDPE High Density Polyethylene Hg Mercury ICP Inductively Coupled Plasma ICP/MS...Inductively Coupled Plasma Mass Spectrometry IROD Interim Record of Decision ITRC Interstate Technology and Regulatory Council K Potassium Kow...alkaline earth metals, alkali metals, and a metalloid, were sampled. This particular demonstration took place at the McClellan Air Force Base (AFB) in

  9. Simultaneous determination of naringenin and hesperetin in rats after oral administration of Da-Cheng-Qi decoction by high-performance liquid chromatography-tandem mass spectrometry.

    PubMed

    Liu, Ying; Xu, Fengguo; Zhang, Zunjian; Song, Rui; Tian, Yuan

    2008-07-01

    To quantify naringenin and hesperetin in rat plasma after oral administration of Da-Cheng-Qi decoction, a famous purgative traditional Chinese medicine, a high-performance liquid chromatography-tandem mass spectrometry method was developed and validated. The HPLC separation was carried out on a Zorbax SB-C(18) column using 0.1% formic acid-methanol as mobile phase and estazolam as internal standard after the sample of rat plasma had been cleaned up with one-step protein precipitation using methanol. Atmospheric pressure chemical ionization in the positive ion mode and selected reaction monitoring method was developed to determine the active components. This method was validated in terms of recovery, linearity, accuracy and precision (intra- and inter-batch variation). The recoveries of naringenin and hesperetin were 72.8-76.6 and 75.7-77.2%, respectively. Linearity in rat plasma was observed over the range of 0.5-250 ng/mL (r2 > 0.99) for both naringenin and hesperetin. The accuracy and precision were well within the acceptable range and the relative standard deviation of the measured rat plasma samples was less than 15% (n = 5). The validated method was successfully applied for the evaluation of the pharmacokinetics of naringenin and hesperetin administered to six rats.

  10. Development and full validation of an UPLC-MS/MS method for the quantification of the plant-derived alkaloid indirubin in rat plasma.

    PubMed

    Jähne, Evelyn A; Sampath, Chethan; Butterweck, Veronika; Hamburger, Matthias; Oufir, Mouhssin

    2016-09-05

    An UPLC-MS/MS method for the quantification of indirubin in lithium heparinized rat plasma was developed and validated according to current international guidelines. Indirubin was extracted from rat plasma by using Waters Ostro™ pass-through sample preparation plates. The method was validated with a LLOQ of 5.00ng/mL and an ULOQ of 500ng/mL. The calibration curve was fitted by least-square quadratic regression, and a weighting factor of 1/X was applied. Recoveries of indirubin and I.S. were consistent and ≥75.5%. Stability studies demonstrated that indirubin was stable in lithium heparinized rat plasma for at least 3 freeze/thaw cycles, for 3h at RT, for 96h in the autosampler at 10°C, and for 84days when stored below -65°C. Preliminary pharmacokinetic (PK) data were obtained from Sprague Dawley rats after intravenous administration of indirubin (2mg/kg b.w.) and blood sampling up to 12h after injection. PK parameters were determined by non-compartmental analysis. Indirubin had a half-life (t1/2) of 35min, and a relatively high clearance (CL) of 2.71L/h/kg. Copyright © 2016 Elsevier B.V. All rights reserved.

  11. Ammonia concentrations in canine whole blood, EDTA-anticoagulated whole blood, and plasma measured by use of a point-of-care ammonia meter.

    PubMed

    Odunayo, Adesola; Tobias, Karen M; Okafor, Chika C; Flatland, Bente

    2017-11-01

    OBJECTIVE To investigate the use of canine whole blood (WB) for measurement of ammonia concentration by use of a point-of-care ammonia meter and to compare results of measuring ammonia concentrations in WB, EDTA-anticoagulated WB, and plasma. ANIMALS 40 client-owned dogs. PROCEDURES A blood sample (2 mL) was obtained from each dog. One drop of WB was immediately applied to a test strip for evaluation with an ammonia meter. The remainder of the blood sample was placed in an EDTA-containing tube, and 1 drop of EDTA-anticoagulated WB was applied to a test strip. The remaining EDTA-anticoagulated WB sample was centrifuged, and the plasma was harvested and placed on ice. One drop of plasma was applied to a test strip; the remainder of the plasma sample was transported on ice and used for ammonia measurement with a reference laboratory instrument. All samples were tested within 1 hour after sample collection. Results were evaluated to detect significant differences in ammonia concentration. RESULTS Ammonia concentrations did not differ significantly between WB and EDTA-anticoagulated WB and between plasma samples measured with the meter and reference laboratory instrument. However, median ammonia concentration was significantly higher in plasma than in WB or EDTA-anti-coagulated WB. CONCLUSIONS AND CLINICAL RELEVANCE Anticoagulant-free WB was a valid sample for measurement by use of the ammonia meter. Plasma samples had higher ammonia concentrations than did WB samples. Results for each sample type should be interpreted by use of specimen- and method-specific reference intervals.

  12. Validation of dilution of plasma samples with phosphate buffered saline to eliminate the problem of small volumes associated with children infected with HIV-1 for viral load testing using Cobas AmpliPrep/COBAS TaqMan HIV-1 test, version 2.0 (CAP CTM HIV v2.0).

    PubMed

    Mine, Madisa; Nkoane, Tapologo; Sebetso, Gaseene; Sakyi, Bright; Makhaola, Kgomotso; Gaolathe, Tendani

    2013-12-01

    The sample requirement of 1 mL for the Roche COBAS AmpliPrep/COBAS TaqMan HIV-1 test, version 2.0 (CAP CTM HIV v2.0) limits its utility in measuring plasma HIV-1 RNA levels for small volume samples from children infected with HIV-1. Viral load monitoring is the standard of care for HIV-1-infected patients on antiretroviral therapy in Botswana. The study aimed to validate the dilution of small volume samples with phosphate buffered saline (1× PBS) when quantifying HIV-1 RNA in patient plasma. HIV RNA concentrations were determined in undiluted and diluted pairs of samples comprising panels of quality assessment standards (n=52) as well as patient samples (n=325). There was strong correlation (R(2)) of 0.98 and 0.95 within the dynamic range of the CAP CTM HIV v2.0 test between undiluted and diluted samples from quality assessment standards and patients, respectively. The difference between viral load measurements of diluted and undiluted pairs of quality assessment standards and patient samples using the Altman-Bland test showed that the 95% limits of agreement were between -0.40 Log 10 and 0.49 Log 10. This difference was within the 0.5 Log 10 which is generally considered as normal assay variation of plasma RNA levels. Dilution of samples with 1× PBS produced comparable viral load measurements to undiluted samples. Copyright © 2013 Elsevier B.V. All rights reserved.

  13. Simple, fast and reliable liquid chromatographic and spectrophotometric methods for the determination of theophylline in urine, saliva and plasma samples.

    PubMed

    Charehsaz, Mohammad; Gürbay, Aylin; Aydin, Ahmet; Sahin, Gönül

    2014-01-01

    In this study, a high-performance liquid chromatographic method (HPLC) and UV spectrophotometric method were developed, validated and applied for the determination of theophylline in biological fluids. Liquid- liquid extraction is performed for isolation of the drug and elimination of plasma and saliva interferences. Urine samples were applied without any extraction. The chromatographic separation was achieved on a C18 column by using 60:40 methanol:water as mobile phase under isocratic conditions at a flow rate of 0.75 mL/min with UV detection at 280 nm in HPLC method. UV spectrophotometric analysis was performed at 275 nm. the limit of quantification: 1.1 µg/mL for urine, 1.9 µg/mL for saliva, 3.1 µg/mL for plasma; recovery: 94.85% for plasma, 100.45% for saliva, 101.39% for urine; intra-day precision: 0.22-2.33%, inter-day precision: 3.17-13.12%. Spectrophotometric analysis results were as follows: the limit of quantitation: 5.23 µg/mL for plasma, 8.7 µg/mL for urine; recovery: 98.27% for plasma, 95.25% for urine; intra-day precision: 2.37 - 3.00%, inter-day precision: 5.43-7.91%. It can be concluded that this validated HPLC method is easy, precise, accurate, sensitive and selective for determination of theophylline in biological samples. Also spectrophotometric analysis can be used where it can be applicable.

  14. Development and validation of LC-MS/MS method for quantitative determination of (-)-securinine in mouse plasma.

    PubMed

    Wabuyele, Simuli L; Wald, David; Xu, Yan

    2014-06-01

    (-)-Securinine (SE) is a major alkaloid found in plant Securinega suffruticosa, which has a wide range of pharmacological activities including anticancer, anti-parasitic and central nervous system stimulating effects, etc. To aid the pharmacological study of SE, we developed an LC-MS/MS method for quantitative determination of SE in mouse plasma. In this method, plasma samples were first prepared with salting-out assisted liquid-liquid extraction using cold acetonitrile (-20°C) and 2.00 M ammonium acetate. Separation of SE and the internal standard (IS) from sample matrix was achieved on a Gemini Nx C18 column using 40% acetonitrile and 60% 10.0mM ammonium acetate at a flow rate of 0.200 mL min(-1). Quantification of SE was accomplished with positive electrospray ionization tandem mass spectrometry using mass transitions m/z 218.1→84.1 for SE, and m/z 204.1→70.2 for the IS. This method has a lower limit of quantitation (LLOQ) of 0.600 ng mL(-1) and a linear calibration range up to 600 ng mL(-1) in mouse plasma. The intra- and inter-run accuracy (%RE) and precision (%CV) were ≤ ± 6% and 6%, respectively. The IS normalized matrix factors from six lots of plasma matrices ranged 0.92-1.07, and the recoveries of plasma SE were 99-109%. The validated method has been applied to the measurement of SE in plasma samples of a mouse study. Copyright © 2014 Elsevier B.V. All rights reserved.

  15. Quantitative determination of dopamine in human plasma by a highly sensitive LC-MS/MS assay: Application in preterm neonates.

    PubMed

    Zhang, Daping; Wu, Lei; Chow, Diana S-L; Tam, Vincent H; Rios, Danielle R

    2016-01-05

    The determination of dopamine facilitates better understanding of the complex brain disorders in the central nervous system and the regulation of endocrine system, cardiovascular functions and renal functions in the periphery. The purpose of this study was to develop a highly sensitive and reliable assay for the quantification of dopamine in human neonate plasma. Dopamine was extracted from human plasma by strong cation exchange (SCX) solid phase extraction (SPE), and subsequently derivatized with propionic anhydride. The derivatized analyte was separated by a Waters Acquity UPLC BEH C18 column using gradient elution at 0.4 ml/min with mobile phases A (0.2% formic acid in water [v/v]) and B (MeOH-ACN [v/v, 30:70]). Analysis was performed under positive electrospray ionization tandem mass spectrometer (ESI-MS/MS) in the multiple reaction monitoring (MRM) mode. The stable and relatively non-polar nature of the derivatized analyte enables reliable quantification of dopamine in the range of 10-1000 pg/ml using 200 μl of plasma sample. The method was validated with intra-day and inter-day precision less than 7%, and the intra-day and inter-day accuracy of 91.9-101.9% and 92.3-102.6%, respectively. The validated assay was applied to quantify dopamine levels in two preterm neonate plasma samples. In conclusion, a sensitive and selective LC-MS/MS method has been developed and validated, and successfully used for the determination of plasma dopamine levels in preterm neonates. Copyright © 2015 Elsevier B.V. All rights reserved.

  16. Development and validation of an UHPLC-ESI-QTOF-MS method for quantification of the highly hydrophilic amyloid-β oligomer eliminating all-D-enantiomeric peptide RD2 in mouse plasma.

    PubMed

    Hupert, Michelle; Elfgen, Anne; Schartmann, Elena; Schemmert, Sarah; Buscher, Brigitte; Kutzsche, Janine; Willbold, Dieter; Santiago-Schübel, Beatrix

    2018-01-15

    During preclinical drug development, a method for quantification of unlabeled compounds in blood plasma samples from treatment or pharmacokinetic studies in mice is required. In the current work, a rapid, specific, sensitive and validated liquid chromatography mass-spectrometric UHPLC-ESI-QTOF-MS method was developed for the quantification of the therapeutic compound RD2 in mouse plasma. RD2 is an all-D-enantiomeric peptide developed for the treatment of Alzheimer's disease, a progressive neurodegenerative disease finally leading to dementia. Due to RD2's highly hydrophilic properties, the sample preparation and the chromatographic separation and quantification were very challenging. The chromatographic separation of RD2 and its internal standard were accomplished on an Acquity UPLC BEH C18 column (2.1 × 100 mm, 1.7 μm particle size) within 6.5 min at 50 °C with a flow rate of 0.5 mL/min. Mobile phases consisted of water and acetonitrile with 1% formic acid and 0.025% heptafluorobutyric acid, respectively. Ions were generated by electrospray ionization (ESI) in the positive mode and the peptide was quantified by QTOF-MS. The developed extraction method for RD2 from mouse plasma revealed complete recovery. The linearity of the calibration curve was in the range of 5.3 ng/mL to 265 ng/mL (r 2  > 0.999) with a lower limit of detection (LLOD) of 2.65 ng/mL and a lower limit of quantification (LLOQ) of 5.3 ng/mL. The intra-day and inter-day accuracy and precision of RD2 in plasma ranged from -0.54% to 2.21% and from 1.97% to 8.18%, respectively. Moreover, no matrix effects were observed and RD2 remained stable in extracted mouse plasma at different conditions. Using this validated bioanalytical method, plasma samples of unlabeled RD2 or placebo treated mice were analyzed. The herein developed UHPLC-ESI-QTOF-MS method is a suitable tool for the quantitative analysis of unlabeled RD2 in plasma samples of treated mice. Copyright © 2017 Elsevier B.V. All rights reserved.

  17. Development and validation of a bioanalytical LC-MS method for the quantification of GHRP-6 in human plasma.

    PubMed

    Gil, Jeovanis; Cabrales, Ania; Reyes, Osvaldo; Morera, Vivian; Betancourt, Lázaro; Sánchez, Aniel; García, Gerardo; Moya, Galina; Padrón, Gabriel; Besada, Vladimir; González, Luis Javier

    2012-02-23

    Growth hormone-releasing peptide 6 (GHRP-6, His-(DTrp)-Ala-Trp-(DPhe)-Lys-NH₂, MW=872.44 Da) is a potent growth hormone secretagogue that exhibits a cytoprotective effect, maintaining tissue viability during acute ischemia/reperfusion episodes in different organs like small bowel, liver and kidneys. In the present work a quantitative method to analyze GHRP-6 in human plasma was developed and fully validated following FDA guidelines. The method uses an internal standard (IS) of GHRP-6 with ¹³C-labeled Alanine for quantification. Sample processing includes a precipitation step with cold acetone to remove the most abundant plasma proteins, recovering the GHRP-6 peptide with a high yield. Quantification was achieved by LC-MS in positive full scan mode in a Q-Tof mass spectrometer. The sensitivity of the method was evaluated, establishing the lower limit of quantification at 5 ng/mL and a range for the calibration curve from 5 ng/mL to 50 ng/mL. A dilution integrity test was performed to analyze samples at higher concentration of GHRP-6. The validation process involved five calibration curves and the analysis of quality control samples to determine accuracy and precision. The calibration curves showed R² higher than 0.988. The stability of the analyte and its internal standard (IS) was demonstrated in all conditions the samples would experience in a real time analyses. This method was applied to the quantification of GHRP-6 in plasma from nine healthy volunteers participating in a phase I clinical trial. Copyright © 2011 Elsevier B.V. All rights reserved.

  18. The development and validation of an UHPLC–MS/MS method for the rapid quantification of the antiretroviral agent dapivirine in human plasma

    PubMed Central

    Seserko, Lauren A; Emory, Joshua F; Hendrix, Craig W; Marzinke, Mark A

    2014-01-01

    Background Dapivirine is a non-nucleoside reverse transcriptase inhibitor designed to prevent HIV-1 viral replication and subsequent propagation. A sensitive method is required to quantify plasma concentrations to assess drug efficacy. Results Dapivirine-spiked plasma was combined with acetonitrile containing deuterated IS and was processed for analysis. The method has an analytical measuring range from 20 to 10,000 pg/ml. For the LLOQ, low, mid and high QCs, intra- and inter-assay precision (%CV) ranged from 5.58 to 13.89% and 5.23 to 13.36%, respectively, and intra- and inter-day accuracy (% deviation) ranged from -5.61 to 0.75% and -4.30 to 6.24%, respectively. Conclusion A robust and sensitive LC–MS/MS assay for the high-throughput quantification of the antiretroviral drug dapivirine in human plasma was developed and validated following bioanalytical validation guidelines. The assay meets criteria for the analysis of samples from large research trials. PMID:24256358

  19. The development and validation of an UHPLC-MS/MS method for the rapid quantification of the antiretroviral agent dapivirine in human plasma.

    PubMed

    Seserko, Lauren A; Emory, Joshua F; Hendrix, Craig W; Marzinke, Mark A

    2013-11-01

    Dapivirine is a non-nucleoside reverse transcriptase inhibitor designed to prevent HIV-1 viral replication and subsequent propagation. A sensitive method is required to quantify plasma concentrations to assess drug efficacy. Dapivirine-spiked plasma was combined with acetonitrile containing deuterated IS and was processed for analysis. The method has an analytical measuring range from 20 to 10,000 pg/ml. For the LLOQ, low, mid and high QCs, intra- and inter-assay precision (%CV) ranged from 5.58 to 13.89% and 5.23 to 13.36%, respectively, and intra- and inter-day accuracy (% deviation) ranged from -5.61 to 0.75% and -4.30 to 6.24%, respectively. A robust and sensitive LC-MS/MS assay for the high-throughput quantification of the antiretroviral drug dapivirine in human plasma was developed and validated following bioanalytical validation guidelines. The assay meets criteria for the analysis of samples from large research trials.

  20. Detection of gastric cancer-associated microRNAs on microRNA microarray comparing pre- and post-operative plasma

    PubMed Central

    Konishi, H; Ichikawa, D; Komatsu, S; Shiozaki, A; Tsujiura, M; Takeshita, H; Morimura, R; Nagata, H; Arita, T; Kawaguchi, T; Hirashima, S; Fujiwara, H; Okamoto, K; Otsuji, E

    2012-01-01

    Background: Recently, it was reported that plasma microRNAs (miRNAs) are low-invasive useful biomarkers for cancer. We attempted to isolate gastric cancer (GC)-associated miRNAs comparing pre- and post-operative paired plasma, thereby excluding the possible effects of individual variability. Methods: This study was divided into four steps: (1) microarray analysis comparing pre- and post-operative plasma; (2) validation of candidate miRNAs by quantitative RT–PCR; (3) validation study of selected miRNAs using paired plasma; and (4) comparison of the levels of selected miRNAs in plasma between healthy controls and patients. Results: From the results of microarray analysis, nine candidate miRNAs the levels of which were markedly decreased in post-operative plasma were selected for further studies. After confirmation of their post-operative marked reduction, two candidate miRNAs, miR-451 and miR-486, were selected as plasma biomarkers, considering the abundance in plasma, and marked decrease in post-operative samples. In validation, the two miRNAs were found to decrease in post-operative plasma in 90 and 93% of patients (both P<0.01). In comparison with healthy controls, the levels of both miRNAs were found to be significantly higher in patients, and the area under the curve values were high at 0.96 and 0.92. Conclusion: Plasma miR-451 and miR-486 could be useful blood-based biomarkers for screening GC. PMID:22262318

  1. Sensitive and rapid liquid chromatography/tandem mass spectrometric assay for the quantification of piperaquine in human plasma.

    PubMed

    Singhal, Puran; Gaur, Ashwani; Gautam, Anirudh; Varshney, Brijesh; Paliwal, Jyoti; Batra, Vijay

    2007-11-01

    A simple, sensitive and rapid liquid chromatography/tandem mass spectrometric (LC-MS/MS) method was developed and validated for quantification of piperaquine, an antimalarial drug, in human plasma using its structural analogue, piperazine bis chloroquinoline as internal standard (IS). The method involved a simple protein precipitation with methanol followed by rapid isocratic elution of analytes with 10mM ammonium acetate buffer/methanol/formic acid/ammonia solution (25/75/0.2/0.15, v/v) on Chromolith SpeedROD RP-18e reversed phase chromatographic column and quantification by mass spectrometry in the multiple reaction monitoring mode (MRM). The precursor to product ion transitions of m/z 535.3-->288.2 and m/z 409.1-->205.2 were used to measure the analyte and the IS, respectively. The assay exhibited a linear dynamic range of 1.0-250.2 ng/mL for piperaquine in plasma. The limit of detection (LOD) and lower limit of quantification (LLOQ) in plasma were 0.2 and 1.0 ng/mL, respectively. Acceptable precision and accuracy (+/-20% deviation for LLOQ standard and +/-15% deviation for other standards from the respective nominal concentration) were obtained for concentrations over the standard curve ranges. A run time of 2.5 min for a sample made it possible to achieve a throughput of more than 400 plasma samples analyzed per day. The validated method was successfully applied to analyze human plasma samples from phase-1 clinical studies. The mean pharmacokinetic parameters of piperaquine following 1000 mg oral dose: observed maximum plasma concentration (Cmax), time to maximum plasma concentration (Tmax) and elimination half-life (T1/2) were 46.1 ng/mL, 3.8h and 13 days, respectively.

  2. Defining Surrogate Endpoints for Clinical Trials in Severe Falciparum Malaria

    PubMed Central

    Plewes, Katherine; Maude, Richard J.; Hanson, Josh; Herdman, M. Trent; Leopold, Stije J.; Ngernseng, Thatsanun; Charunwatthana, Prakaykaew; Phu, Nguyen Hoan; Ghose, Aniruddha; Hasan, M. Mahtab Uddin; Fanello, Caterina I.; Faiz, Md Abul; Hien, Tran Tinh; Day, Nicholas P. J.; White, Nicholas J.; Dondorp, Arjen M.

    2017-01-01

    Background Clinical trials in severe falciparum malaria require a large sample size to detect clinically meaningful differences in mortality. This means few interventions can be evaluated at any time. Using a validated surrogate endpoint for mortality would provide a useful alternative allowing a smaller sample size. Here we evaluate changes in coma score and plasma lactate as surrogate endpoints for mortality in severe falciparum malaria. Methods Three datasets of clinical studies in severe malaria were re-evaluated: studies from Chittagong, Bangladesh (adults), the African ‘AQUAMAT’ trial comparing artesunate and quinine (children), and the Vietnamese ‘AQ’ study (adults) comparing artemether with quinine. The absolute change, relative change, slope of the normalization over time, and time to normalization were derived from sequential measurements of plasma lactate and coma score, and validated for their use as surrogate endpoint, including the proportion of treatment effect on mortality explained (PTE) by these surrogate measures. Results Improvements in lactate concentration or coma scores over the first 24 hours of admission, were strongly prognostic for survival in all datasets. In hyperlactataemic patients in the AQ study (n = 173), lower mortality with artemether compared to quinine closely correlated with faster reduction in plasma lactate concentration, with a high PTE of the relative change in plasma lactate at 8 and 12 hours of 0.81 and 0.75, respectively. In paediatric patients enrolled in the ‘AQUAMAT’ study with cerebral malaria (n = 785), mortality was lower with artesunate compared to quinine, but this was not associated with faster coma recovery. Conclusions The relative changes in plasma lactate concentration assessed at 8 or 12 hours after admission are valid surrogate endpoints for severe malaria studies on antimalarial drugs or adjuvant treatments aiming at improving the microcirculation. Measures of coma recovery are not valid surrogate endpoints for mortality. PMID:28052109

  3. Defining Surrogate Endpoints for Clinical Trials in Severe Falciparum Malaria.

    PubMed

    Jeeyapant, Atthanee; Kingston, Hugh W; Plewes, Katherine; Maude, Richard J; Hanson, Josh; Herdman, M Trent; Leopold, Stije J; Ngernseng, Thatsanun; Charunwatthana, Prakaykaew; Phu, Nguyen Hoan; Ghose, Aniruddha; Hasan, M Mahtab Uddin; Fanello, Caterina I; Faiz, Md Abul; Hien, Tran Tinh; Day, Nicholas P J; White, Nicholas J; Dondorp, Arjen M

    2017-01-01

    Clinical trials in severe falciparum malaria require a large sample size to detect clinically meaningful differences in mortality. This means few interventions can be evaluated at any time. Using a validated surrogate endpoint for mortality would provide a useful alternative allowing a smaller sample size. Here we evaluate changes in coma score and plasma lactate as surrogate endpoints for mortality in severe falciparum malaria. Three datasets of clinical studies in severe malaria were re-evaluated: studies from Chittagong, Bangladesh (adults), the African 'AQUAMAT' trial comparing artesunate and quinine (children), and the Vietnamese 'AQ' study (adults) comparing artemether with quinine. The absolute change, relative change, slope of the normalization over time, and time to normalization were derived from sequential measurements of plasma lactate and coma score, and validated for their use as surrogate endpoint, including the proportion of treatment effect on mortality explained (PTE) by these surrogate measures. Improvements in lactate concentration or coma scores over the first 24 hours of admission, were strongly prognostic for survival in all datasets. In hyperlactataemic patients in the AQ study (n = 173), lower mortality with artemether compared to quinine closely correlated with faster reduction in plasma lactate concentration, with a high PTE of the relative change in plasma lactate at 8 and 12 hours of 0.81 and 0.75, respectively. In paediatric patients enrolled in the 'AQUAMAT' study with cerebral malaria (n = 785), mortality was lower with artesunate compared to quinine, but this was not associated with faster coma recovery. The relative changes in plasma lactate concentration assessed at 8 or 12 hours after admission are valid surrogate endpoints for severe malaria studies on antimalarial drugs or adjuvant treatments aiming at improving the microcirculation. Measures of coma recovery are not valid surrogate endpoints for mortality.

  4. Simultaneous quantification of reparixin and paclitaxel in plasma and urine using ultra performance liquid chromatography-tandem mass spectroscopy (UHPLC-MS/MS): Application to a preclinical pharmacokinetic study in rats.

    PubMed

    Malhi, Sarandeep; Stesco, Nicholas; Alrushaid, Samaa; Lakowski, Ted M; Davies, Neal M; Gu, Xiaochen

    2017-03-01

    A liquid chromatography-tandem mass spectroscopy (LC-MS/MS) assay was developed and validated to simultaneously quantify anticancer drugs reparixin and paclitaxel in this study. The compounds were extracted from plasma and urine samples by protein precipitation with acetone (supplemented with 0.1% formic acid). Chromatographic separation was achieved using a C18 column, and drug molecules were ionized using dual ion source electrospray and atmospheric pressure chemical ionization (DUIS: ESI-APCI). Reparixin and paclitaxel were quantified using negative and positive multiple reaction monitoring (MRM) mode, respectively. Stable isotope palcitaxel-D5 was used as the internal standard (IS). The assay was validated for specificity, recovery, carryover and sample stability under various storage conditions; it was also successfully applied to measure drug concentrations collected from a pharmacokinetic study in rats. The results confirmed that the assay was accurate and simple in quantifying both reparixin and paclitaxel in plasma and urine with minimal sample pretreatment. Copyright © 2016 Elsevier B.V. All rights reserved.

  5. High-sensitivity simultaneous liquid chromatography-tandem mass spectrometry assay of ethinyl estradiol and levonorgestrel in human plasma.

    PubMed

    Gandhi, Abhishek; Guttikar, Swati; Trivedi, Priti

    2015-10-01

    A sensitive and simultaneous liquid chromatography-tandem mass spectrometry method was developed and validated for quantification of ethinyl estradiol and levonorgestrel. The analytes were extracted with methyl-tert-butyl ether: n-hexane (50:50, v/v) solvent mixture, followed by dansyl derivatization. The chromatographic separation was performed on a Kinetex C 18 (50 mm×4.6 mm, 2.6 µm) column with a mobile phase of 0.1% (v/v) formic acid in water and acetonitrile in gradient composition. The mass transitions were monitored in electrospray positive ionization mode. The assay exhibited a linear range of 0.100-20.0 ng/mL for levonorgestrel and 4.00-500 pg/mL for ethinyl estradiol in human plasma. A run time of 9.0 min for each sample made it possible to analyze a throughput of more than 100 samples per day. The validated method has been successfully used to analyze human plasma samples for application in pharmacokinetic and bioequivalence studies.

  6. Fabric phase sorptive extraction-high performance liquid chromatography-photo diode array detection method for simultaneous monitoring of three inflammatory bowel disease treatment drugs in whole blood, plasma and urine.

    PubMed

    Kabir, Abuzar; Furton, Kenneth G; Tinari, Nicola; Grossi, Laurino; Innosa, Denise; Macerola, Daniela; Tartaglia, Angela; Di Donato, Valentina; D'Ovidio, Cristian; Locatelli, Marcello

    2018-05-01

    This paper reports a novel fabric phase sorptive extraction-high performance liquid chromatography-photodiode array detection (FPSE-HPLC-PDA) method for the simultaneous extraction and analysis of three drug residues (ciprofloxacin, sulfasalazine, and cortisone) in human whole blood, plasma, and urine samples, generally administered in human patients to treat inflammatory bowel disease (IBD). The drugs of interest were well resolved using a Luna C 18 column (250 mm × 4.6 mm; 5 μm particle size) in gradient elution mode within 20 min. The analytical method was optimized and validated in the range 0.05-10 μg/mL for whole blood, 0.25-10 μg/mL for human plasma, and 0.10-10 μg/mL for human urine. Blank human whole blood, plasma, and urine were used as the sample matrix for the method development and validation; while methyl-p-hydroxybenzoate was used as the internal standard (IS). Weighted-matrix matched standard calibration curves showed a good linearity up to a concentration of 10 μg/mL. The intra- and inter-day accuracy values (precision and trueness) were found in the range from -10.9% to 12.3%, and the performances of the validated FPSE-HPLC-PDA were further tested on real IBD patient samples. This is the first FPSE procedure applied simultaneously to whole blood, plasma, and urine samples for the determination of residual IBD drugs, which possess a wide range of polarity (logP values ranging from 2.30 for Ciprofloxacin, to 1.66 for Cortisone, and 2.92 for Sulfasalazine). The new approach exhibits high potential for immediate adoptation as a rapid, robust and green analytical tool for future clinical and pharmaceutical applications. Copyright © 2018 Elsevier B.V. All rights reserved.

  7. Validation of a sensitive LC-MS assay for quantification of glyburide and its metabolite 4-transhydroxy glyburide in plasma and urine: an OPRU Network study

    PubMed Central

    Naraharisetti, Suresh Babu; Kirby, Brian J.; Hebert, Mary F.; Easterling, Thomas R.; Unadkat, Jashvant D.

    2009-01-01

    Glyburide (glibenclamide, INN), a second generation sulfonylurea is widely used in the treatment of gestational diabetes mellitus (GDM). None of the previously reported analytical methods provide adequate sensitivity for the expected sub-nanogram/mL maternal and umbilical cord plasma concentrations of glyburide during pregnancy. We developed and validated a sensitive and low sample volume liquid chromatographic-mass spectrometric (LC-MS) method for simultaneous determination of glyburide (GLY) and its metabolite, 4-transhydroxy glyburide (M1) in human plasma (0.5 ml) or urine (0.1 ml). The limits of quantitation (LOQ) for GLY and M1 in plasma were 0.25 and 0.40 ng/mL, respectively whereas it was 1.06 ng/mL for M1 in urine. As measured by quality control samples, precision (% coefficient of variation) of the assay was < 15% whereas the accuracy (% deviation from expected) ranged from −10.1–14.3%. We found that the GLY metabolite, M1 is excreted in the urine as the glucuronide-conjugate. PMID:17980680

  8. Optical diagnosis of malaria infection in human plasma using Raman spectroscopy

    NASA Astrophysics Data System (ADS)

    Bilal, Muhammad; Saleem, Muhammad; Amanat, Samina Tufail; Shakoor, Huma Abdul; Rashid, Rashad; Mahmood, Arshad; Ahmed, Mushtaq

    2015-01-01

    We present the prediction of malaria infection in human plasma using Raman spectroscopy. Raman spectra of malaria-infected samples are compared with those of healthy and dengue virus infected ones for disease recognition. Raman spectra were acquired using a laser at 532 nm as an excitation source and 10 distinct spectral signatures that statistically differentiated malaria from healthy and dengue-infected cases were found. A multivariate regression model has been developed that utilized Raman spectra of 20 malaria-infected, 10 non-malarial with fever, 10 healthy, and 6 dengue-infected samples to optically predict the malaria infection. The model yields the correlation coefficient r2 value of 0.981 between the predicted values and clinically known results of trainee samples, and the root mean square error in cross validation was found to be 0.09; both these parameters validated the model. The model was further blindly tested for 30 unknown suspected samples and found to be 86% accurate compared with the clinical results, with the inaccuracy due to three samples which were predicted in the gray region. Standard deviation and root mean square error in prediction for unknown samples were found to be 0.150 and 0.149, which are accepted for the clinical validation of the model.

  9. Monitoring of platinum surface contamination in seven Dutch hospital pharmacies using inductively coupled plasma mass spectrometry

    PubMed Central

    Huitema, A. D. R.; Bakker, E. N.; Douma, J. W.; Schimmel, K. J. M.; van Weringh, G.; de Wolf, P. J.; Schellens, J. H. M.; Beijnen, J. H.

    2007-01-01

    Objective: To develop, validate, and apply a method for the determination of platinum contamination, originating from cisplatinum, oxaliplatinum, and carboplatinum. Methods: Inductively coupled plasma mass spectrometry (ICP-MS) was used to determine platinum in wipe samples. The sampling procedure and the analytical conditions were optimised and the assay was validated. The method was applied to measure surface contamination in seven Dutch hospital pharmacies. Results: The developed method allowed reproducible quantification of 0.50 ng l−1 platinum (5 pg/wipe sample). Recoveries for stainless steel and linoleum surfaces ranged between 50.4 and 81.4% for the different platinum compounds tested. Platinum contamination was reported in 88% of the wipe samples. Although a substantial variation in surface contamination of the pharmacies was noticed, in most pharmacies, the laminar-airflow (LAF) hoods, the floor in front of the LAF hoods, door handles, and handles of service hatches showed positive results. This demonstrates that contamination is spread throughout the preparation rooms. Conclusion: We developed and validated an ultra sensitive and reliable ICP-MS method for the determination of platinum in surface samples. Surface contamination with platinum was observed in all hospital pharmacies sampled. The interpretation of these results is, however, complicated. PMID:17377802

  10. Simultaneous determination of paeoniflorin, albiflorin, ferulic acid, tetrahydropalmatine, protopine, typhaneoside, senkyunolide I in Beagle dogs plasma by UPLC-MS/MS and its application to a pharmacokinetic study after Oral Administration of Shaofu Zhuyu Decoction.

    PubMed

    Huang, Xiaochen; Su, Shulan; Cui, Wenxia; Liu, Pei; Duan, Jin-ao; Guo, Jianming; Li, Zhenhao; Shang, Erxin; Qian, Dawei; Huang, Zhijun

    2014-07-01

    In this present study, a sensitive and rapid UPLC-MS/MS method was developed for simultaneous quantification of paeoniflorin, albiflorin, ferulic acid, tetrahydropalmatine, protopine, typhaneoside and senkyunolide I in Beagle dog plasma after oral administration of the Shao-Fu-Zhu-Yu Decoction. Chloramphenicol and clarithromycin were used as internal standards. Plasma samples were processed by protein precipitation with methanol. The separation was performed on an Acquity BEH C18 column (100mm×2.1mm, 1.7μm) at a flow-rate of 0.4mL/min, using 0.1% formic acid-acetonitrile as mobile phase. Method validation was performed as per Food and Drug Administration guidelines and the results met the acceptance criteria. After validation, this method was successfully applied to a pharmacokinetic study. The results showed that the apparent plasma clearance of paeoniflorin, albiflorin, typhaneoside and senkyunolide I were significantly higher than others. Double peak was observed in plasma concentration curves of tetrahydropalmatine, the ferulic acid had a good absorption in Beagle dog plasma, and senkyunolide I was detected in plasma from the first blood sampling time (15min) and rapidly reached Tmax. The compound of typhaneoside has a low bioavailability according to the results. Copyright © 2014. Published by Elsevier B.V.

  11. A validated inductively coupled plasma mass spectrometry (ICP-MS) method for the quantification of total platinum content in plasma, plasma ultrafiltrate, urine and peritoneal fluid.

    PubMed

    Lemoine, Lieselotte; Thijssen, Elsy; Noben, Jean-Paul; Adriaensens, Peter; Carleer, Robert; Speeten, Kurt Van der

    2018-04-15

    Oxaliplatin is a platinum (Pt) 1 containing antineoplastic agent that is applied in current clinical practice for the treatment of colon and appendiceal neoplasms. A fully validated, highly sensitive, high throughput inductively coupled plasma mass spectrometry (ICP-MS) method is provided to quantify the total Pt content in plasma, plasma ultrafiltrate, urine and peritoneal fluid. In this ICP-MS approach, the only step of sample preparation is a 1000-fold dilution in 0.5% nitric acid, allowing the analysis of 17 samples per hour. Detection of Pt was achieved over a linear range of 0.01-100 ng/mL. The limit of quantification was 18.0 ng/mL Pt in plasma, 8.0 ng/mL in ultrafiltrate and 6.1 ng/mL in urine and peritoneal fluid. The ICP-MS method was further validated for inter-and intraday precision and accuracy (≤15%), recovery, robustness and stability. Short-term storage of the biofluids, for 14 days, can be performed at -4 °C, -24 °C and -80 °C. As to long-term stability, up to 5 months, storage at -80 °C is encouraged. Furthermore, a timeline assessing the total and unbound Pt fraction in plasma and ultrafiltrate over a period of 45 h is provided. Following an incubation period of 5 h at 37 °C, 19-21% of Pt was recovered in the ultrafiltrate, emphasizing the extensive and rapid binding of oxaliplatin-derived Pt to plasma proteins. The described method can easily be implemented in a routine setting for pharmacokinetic studies in patients treated with oxaliplatin-based hyperthermic intraperitoneal perioperative chemotherapy. Copyright © 2018 Elsevier B.V. All rights reserved.

  12. Comparison of the quantification of acetaminophen in plasma, cerebrospinal fluid and dried blood spots using high-performance liquid chromatography-tandem mass spectrometry.

    PubMed

    Taylor, Rachel R; Hoffman, Keith L; Schniedewind, Björn; Clavijo, Claudia; Galinkin, Jeffrey L; Christians, Uwe

    2013-09-01

    Acetaminophen (paracetamol, N-(4-hydroxyphenyl) acetamide) is one of the most commonly prescribed drugs for the management of pain in children. Quantification of acetaminophen in pre-term and term neonates and small children requires the availability of highly sensitive assays in small volume blood samples. We developed and validated an LC-MS/MS assay for the quantification of acetaminophen in human plasma, cerebro-spinal fluid (CSF) and dried blood spots (DBS). Reconstitution in water (DBS only) and addition of a protein precipitation solution containing the deuterated internal standard were the only manual steps. Extracted samples were analyzed on a Kinetex 2.6 μm PFP column using an acetonitrile/formic acid gradient. The analytes were detected in the positive multiple reaction mode. Alternatively, DBS were automatically processed using direct desorption in a sample card and preparation (SCAP) robotic autosampler in combination with online extraction. The range of reliable response in plasma and CSF was 3.05-20,000 ng/ml (r(2)>0.99) and 27.4-20,000 ng/ml (r(2)>0.99) for DBS (manual extraction and automated direct desorption). Inter-day accuracy was always within 85-115% and inter-day precision for plasma, CSF and manually extracted DBS were less than 15%. Deming regression analysis comparing 167 matching pairs of plasma and DBS samples showed a correlation coefficient of 0.98. Bland Altman analysis indicated a 26.6% positive bias in DBS, most likely reflecting the blood: plasma distribution ratio of acetaminophen. DBS are a valid matrix for acetaminophen pharmacokinetic studies. Copyright © 2013 Elsevier B.V. All rights reserved.

  13. A validated UPLC-MS/MS method for flibanserin in plasma and its pharmacokinetic interaction with bosentan in rats.

    PubMed

    Iqbal, Muzaffar; Ezzeldin, Essam; Rezk, Naser L; Bajrai, Amal A; Al-Rashood, Khalid A

    2018-04-25

    The purpose of this study was development, validation and application of ultra-performance liquid chromatography (UPLC)-ESI-MS/MS method for quantitation of flibanserin in plasma samples. After extraction of analyte from plasma by diethyl ether, separation was performed on UPLC C 18 column using mobile phase composition of 10 mM ammonium formate-acetonitrile (30:70, v/v) by isocratic elution of 0.3 ml/min. The multiple reaction monitoring transitions of m/z 391.13→ 161.04 and 384.20→ 253.06 were used for detection of analyte and internal standard (quetiapine), respectively. The calibration curves were linear (r ≥0.995) between 0.22 and 555 ng/ml concentration and all validation results were within the acceptable range as per US FDA guidelines. The assay procedure was fully validated and successfully applied in pharmacokinetic interaction study of flibanserin with bosentan in rats.

  14. Heparin removal by ecteola-cellulose pre-treatment enables the use of plasma samples for accurate measurement of anti-Yellow fever virus neutralizing antibodies.

    PubMed

    Campi-Azevedo, Ana Carolina; Peruhype-Magalhães, Vanessa; Coelho-Dos-Reis, Jordana Grazziela; Costa-Pereira, Christiane; Yamamura, Anna Yoshida; Lima, Sheila Maria Barbosa de; Simões, Marisol; Campos, Fernanda Magalhães Freire; de Castro Zacche Tonini, Aline; Lemos, Elenice Moreira; Brum, Ricardo Cristiano; de Noronha, Tatiana Guimarães; Freire, Marcos Silva; Maia, Maria de Lourdes Sousa; Camacho, Luiz Antônio Bastos; Rios, Maria; Chancey, Caren; Romano, Alessandro; Domingues, Carla Magda; Teixeira-Carvalho, Andréa; Martins-Filho, Olindo Assis

    2017-09-01

    Technological innovations in vaccinology have recently contributed to bring about novel insights for the vaccine-induced immune response. While the current protocols that use peripheral blood samples may provide abundant data, a range of distinct components of whole blood samples are required and the different anticoagulant systems employed may impair some properties of the biological sample and interfere with functional assays. Although the interference of heparin in functional assays for viral neutralizing antibodies such as the functional plaque-reduction neutralization test (PRNT), considered the gold-standard method to assess and monitor the protective immunity induced by the Yellow fever virus (YFV) vaccine, has been well characterized, the development of pre-analytical treatments is still required for the establishment of optimized protocols. The present study intended to optimize and evaluate the performance of pre-analytical treatment of heparin-collected blood samples with ecteola-cellulose (ECT) to provide accurate measurement of anti-YFV neutralizing antibodies, by PRNT. The study was designed in three steps, including: I. Problem statement; II. Pre-analytical steps; III. Analytical steps. Data confirmed the interference of heparin on PRNT reactivity in a dose-responsive fashion. Distinct sets of conditions for ECT pre-treatment were tested to optimize the heparin removal. The optimized protocol was pre-validated to determine the effectiveness of heparin plasma:ECT treatment to restore the PRNT titers as compared to serum samples. The validation and comparative performance was carried out by using a large range of serum vs heparin plasma:ECT 1:2 paired samples obtained from unvaccinated and 17DD-YFV primary vaccinated subjects. Altogether, the findings support the use of heparin plasma:ECT samples for accurate measurement of anti-YFV neutralizing antibodies. Copyright © 2017 Elsevier B.V. All rights reserved.

  15. Development of a Rapid LC-MS/MS Method for the Determination of Emerging Fusarium mycotoxins Enniatins and Beauvericin in Human Biological Fluids

    PubMed Central

    Serrano, Ana Belén; Capriotti, Anna Laura; Cavaliere, Chiara; Piovesana, Susy; Samperi, Roberto; Ventura, Salvatore; Laganà, Aldo

    2015-01-01

    A novel method for the simultaneous determination of enniatins A, A1, B and B1 and beauvericin, both in human urine and plasma samples, was developed and validated. The method consisted of a simple and easy pretreatment, specific for each matrix, followed by solid phase extraction (SPE) and detection by high performance liquid chromatography-tandem mass spectrometry with an electrospray ion source. The optimized SPE method was performed on graphitized carbon black cartridges after suitable dilution of the extracts, which allowed high mycotoxin absolute recoveries (76%–103%) and the removal of the major interferences from the matrix. The method was extensively evaluated for plasma and urine samples separately, providing satisfactory results in terms of linearity (R2 of 0.991–0.999), process efficiency (>81%), trueness (recoveries between 85% and 120%), intra-day precision (relative standard deviation, RSD < 18%), inter-day precision (RSD < 21%) and method quantification limits (ranging between 20 ng·L−1 and 40 ng·L−1 in plasma and between 5 ng·L−1 and 20 ng·L−1 in urine). Finally, the highly sensitive validated method was applied to some urine and plasma samples from different donors. PMID:26371043

  16. Simultaneous high-performance liquid chromatography-tandem mass spectrometry (HPLC-MS-MS) analysis of cyanide and thiocyanate from swine plasma.

    PubMed

    Bhandari, Raj K; Manandhar, Erica; Oda, Robert P; Rockwood, Gary A; Logue, Brian A

    2014-01-01

    An analytical procedure for the simultaneous determination of cyanide and thiocyanate in swine plasma was developed and validated. Cyanide and thiocyanate were simultaneously analyzed by high-performance liquid chromatography tandem mass spectrometry in negative ionization mode after rapid and simple sample preparation. Isotopically labeled internal standards, Na(13)C(15)N and NaS(13)C(15)N, were mixed with swine plasma (spiked and nonspiked), proteins were precipitated with acetone, the samples were centrifuged, and the supernatant was removed and dried. The dried samples were reconstituted in 10 mM ammonium formate. Cyanide was reacted with naphthalene-2,3-dicarboxaldehyde and taurine to form N-substituted 1-cyano[f]benzoisoindole, while thiocyanate was chemically modified with monobromobimane to form an SCN-bimane product. The method produced dynamic ranges of 0.1-50 and 0.2-50 μM for cyanide and thiocyanate, respectively, with limits of detection of 10 nM for cyanide and 50 nM for thiocyanate. For quality control standards, the precision, as measured by percent relative standard deviation, was below 8 %, and the accuracy was within ±10 % of the nominal concentration. Following validation, the analytical procedure successfully detected cyanide and thiocyanate simultaneously from the plasma of cyanide-exposed swine.

  17. Determination of the neuropharmacological drug nodakenin in rat plasma and brain tissues by liquid chromatography tandem mass spectrometry: Application to pharmacokinetic studies.

    PubMed

    Song, Yingshi; Yan, Huiyu; Xu, Jingbo; Ma, Hongxi

    2017-09-01

    A rapid and sensitive liquid chromatography tandem mass spectrometry detection using selected reaction monitoring in positive ionization mode was developed and validated for the quantification of nodakenin in rat plasma and brain. Pareruptorin A was used as internal standard. A single step liquid-liquid extraction was used for plasma and brain sample preparation. The method was validated with respect to selectivity, precision, accuracy, linearity, limit of quantification, recovery, matrix effect and stability. Lower limit of quantification of nodakenin was 2.0 ng/mL in plasma and brain tissue homogenates. Linear calibration curves were obtained over concentration ranges of 2.0-1000 ng/mL in plasma and brain tissue homogenates for nodakenin. Intra-day and inter-day precisions (relative standard deviation, RSD) were <15% in both biological media. This assay was successfully applied to plasma and brain pharmacokinetic studies of nodakenin in rats after intravenous administration. Copyright © 2017 John Wiley & Sons, Ltd.

  18. Quantification of seven β-lactam antibiotics and two β-lactamase inhibitors in human plasma using a validated UPLC-MS/MS method.

    PubMed

    Carlier, Mieke; Stove, Veronique; Roberts, Jason A; Van de Velde, Eric; De Waele, Jan J; Verstraete, Alain G

    2012-11-01

    There is an increasing interest in monitoring plasma concentrations of β-lactam antibiotics. The objective of this work was to develop and validate a rapid ultra-performance liquid chromatographic method with tandem mass spectrometric detection (UPLC-MS/MS) for simultaneous quantification of amoxicillin, ampicillin, cefuroxime, cefazolin, ceftazidime, meropenem, piperacillin, clavulanic acid and tazobactam. Sample clean-up included protein precipitation with acetonitrile and back-extraction of acetonitrile with dichloromethane. Six deuterated β-lactam antibiotics were used as internal standards. Chromatographic separation was performed on a Waters ACQUITY UPLC system using a BEH C(18) column (1.7 μm, 100 mm×2.1 mm) applying a binary gradient elution of water and acetonitrile both containing 0.1% formic acid. The total run time was 5.5 min. The developed method was validated in terms of precision, accuracy, linearity, matrix effect and recovery. The assay has now been successfully used to determine concentrations of amoxicillin/clavulanic acid, cefuroxime and meropenem in plasma samples from intensive care patients. Copyright © 2012 Elsevier B.V. and the International Society of Chemotherapy. All rights reserved.

  19. Quantification of myo-inositol, 1,5-anhydro-D-sorbitol, and D-chiro-inositol using high-performance liquid chromatography with electrochemical detection in very small volume clinical samples

    PubMed Central

    Schimpf, Karen J.; Meek, Claudia C.; Leff, Richard D.; Phelps, Dale L.; Schmitz, Daniel J.; Cordle, Christopher T.

    2015-01-01

    Inositol is a six-carbon sugar alcohol and is one of nine biologically significant isomers of hexahydroxycyclohexane. Myo-inositol is the primary biologically active form and is present in higher concentrations in the fetus and newborn than in adults. It is currently being examined for the prevention of retinopathy of prematurity in newborn preterm infants. A robust method for quantifying myo-inositol (MI), D-chiro-inositol (DCI) and 1,5-anhydro-D-sorbitol (ADS) in very small-volume (25 μL) urine, blood serum and/or plasma samples was developed. Using a multiple-column, multiple mobile phase liquid chromatographic system with electrochemical detection, the method was validated with respect to (a) selectivity, (b) accuracy/recovery, (c) precision/reproducibility, (d) sensitivity, (e) stability and (f) ruggedness. The standard curve was linear and ranged from 0.5 to 30 mg/L for each of the three analytes. Above-mentioned performance measures were within acceptable limits described in the Food and Drug Administration’s Guidance for Industry: Bioanalytical Method Validation. The method was validated using blood serum and plasma collected using four common anticoagulants, and also by quantifying the accuracy and sensitivity of MI measured in simulated urine samples recovered from preterm infant diaper systems. The method performs satisfactorily measuring the three most common inositol isomers on 25 μL clinical samples of serum, plasma milk, and/or urine. Similar performance is seen testing larger volume samples of infant formulas and infant formula ingredients. MI, ADS and DCI may be accurately tested in urine samples collected from five different preterm infant diapers if the urine volume is greater than 2–5 mL. PMID:26010453

  20. Development and validation of a high performance liquid chromatographic method for the determination of oxcarbazepine and its main metabolites in human plasma and cerebrospinal fluid and its application to pharmacokinetic study.

    PubMed

    Kimiskidis, Vasilios; Spanakis, Marios; Niopas, Ioannis; Kazis, Dimitrios; Gabrieli, Chrysi; Kanaze, Feras Imad; Divanoglou, Daniil

    2007-01-17

    An isocratic reversed-phase HPLC-UV procedure for the determination of oxcarbazepine and its main metabolites 10-hydroxy-10,11-dihydrocarbamazepine and 10,11-dihydroxy-trans-10,11-dihydrocarbamazepine in human plasma and cerebrospinal fluid has been developed and validated. After addition of bromazepam as internal standard, the analytes were isolated from plasma and cerebrospinal fluid by liquid-liquid extraction. Separation was achieved on a X-TERRA C18 column using a mobile phase composed of 20 mM KH(2)PO(4), acetonitrile, and n-octylamine (76:24:0.05, v/v/v) at 40 degrees C and detected at 237 nm. The described assay was validated in terms of linearity, accuracy, precision, recovery and lower limit of quantification according to the FDA validation guidelines. Calibration curves were linear with a coefficient of variation (r) greater than 0.998. Accuracy ranged from 92.3% to 106.0% and precision was between 2.3% and 8.2%. The method has been applied to plasma and cerebrospinal fluid samples obtained from patients treated with oxcarbazepine, both in monotherapy and adjunctive therapy.

  1. Analysis of non-esterified fatty acids in human samples by solid-phase-extraction and gas chromatography/mass spectrometry.

    PubMed

    Kopf, Thomas; Schmitz, Gerd

    2013-11-01

    The determination of the fatty acid (FA) profile of lipid classes is essential for lipidomic analysis. We recently developed a GC/MS-method for the analysis of the FA profile of total FAs, i.e. the totality of bound and unbound FAs, in any given biological sample (TOFAs). Here, we present a method for the analysis of non-esterified fatty acids (NEFAs) in biological samples, i.e. the fraction that is present as extractable free fatty acids. Lipid extraction is performed according to Dole using 80/20 2-propanol/n-hexane (v/v), with 0.1% H2SO4. The fatty acid-species composition of this NEFA-fraction is determined as FAME after derivatization with our GC/MS-method on a BPX column (Shimadzu). Validation of the NEFA-method presented was performed in human plasma samples. The validated method has been used with human plasma, cells and tissues, as well as mammalian body fluids and tissue samples. The newly developed solid-phase-extraction (SPE)-GC-MS method allows the rapid separation of the NEFA-fraction from a neutral lipid extract of plasma samples. As a major advantage compared to G-FID-methods, GC-MS allows the use of stable isotope labeled fatty acid precursors to monitor fatty acid metabolism. Copyright © 2013 Elsevier B.V. All rights reserved.

  2. Quantification of amlodipine and atorvastatin in human plasma by UPLC-MS/MS method and its application to a bioequivalence study.

    PubMed

    Rezk, Mamdouh R; Badr, Kamal A

    2018-07-01

    A robust, rapid and sensitive UPLC-MS/MS method has been developed, optimized and validated for the determination of amlodipine (AML) and atorvastatin (ATO) in human plasma using eplerenone as an internal standard (IS). Multiple-reaction monitoring in positive electrospray ionization mode was utilized in Xevo TQD LC-MS/MS. Double extraction was used in sample preparation using diethyl ether and ethyl acetate. The prepared samples were analyzed using an Acquity UPLC BEH C 18 (50 × 2.1 mm, 1.7 μm) column. Ammonium formate and acetonitrile, pumped isocraticaly at a flow rate of 0.25 mL/min, were used as a mobile phase. Method validation was done as per the US Food and Drug Administration guidelines. Linearity was achieved in the range of 0.1-10 ng/mL for AML and 0.05-50 ng/mL for ATO. Intra-day and inter-day accuracy and precision were calculated and found to be within the acceptable range. A short run time, of <1.5 min, permits analysis of a large number of plasma samples per batch. The developed and validated method was applied to estimate AML and ATO in a bioequivalence study in healthy human volunteers. Copyright © 2018 John Wiley & Sons, Ltd.

  3. A strategy for extending the applicability of a validated plasma calibration curve to quantitative measurements in multiple tissue homogenate samples: a case study from a rat tissue distribution study of JI-101, a triple kinase inhibitor.

    PubMed

    Gurav, Sandip Dhondiram; Jeniffer, Sherine; Punde, Ravindra; Gilibili, Ravindranath Reddy; Giri, Sanjeev; Srinivas, Nuggehally R; Mullangi, Ramesh

    2012-04-01

    A general practice in bioanalysis is that, whatever the biological matrix the analyte is being quantified in, the validation is performed in the same matrix as per regulatory guidelines. In this paper, we are presenting the applicability of a validated LC-MS/MS method in rat plasma for JI-101, to estimate the concentrations of JI-101 in various tissues that were harvested in a rat tissue distribution study. A simple protein precipitation technique was used to extract JI-101 and internal standard from the tissue homogenates. The recovery of JI-101 in all the matrices was found to be >70%. Chromatographic separation was achieved using a binary gradient using mobile phase A (acetonitrile) and B (0.2% formic acid in water) at a flow rate of 0.30 mL/min on a Prodigy ODS column with a total run time of 4.0 min. The MS/MS ion transitions monitored were 466.1 → 265 for JI-101 and 180.1 → 110.1 for internal standard. The linearity range was 5.02-4017 ng/mL. The JI-101 levels were quantifiable in the various tissue samples harvested in this study. Therefore, the use of a previously validated JI-101 assay in plasma circumvented the tedious process of method development/validation in various tissue matrices. Copyright © 2011 John Wiley & Sons, Ltd.

  4. Quantitative determination of metformin, glyburide and its metabolites in plasma and urine of pregnant patients by LC-MS/MS.

    PubMed

    Zhang, Xing; Wang, Xiaoming; Vernikovskaya, Daria I; Fokina, Valentina M; Nanovskaya, Tatiana N; Hankins, Gary D V; Ahmed, Mahmoud S

    2015-04-01

    This report describes the development and validation of an LC-MS/MS method for the quantitative determination of glyburide (GLB), its five metabolites (M1, M2a, M2b, M3 and M4) and metformin (MET) in plasma and urine of pregnant patients under treatment with a combination of the two medications. The extraction recovery of the analytes from plasma samples was 87-99%, and that from urine samples was 85-95%. The differences in retention times among the analytes and the wide range of the concentrations of the medications and their metabolites in plasma and urine patient samples required the development of three LC methods. The lower limit of quantitation (LLOQ) of the analytes in plasma samples was as follows: GLB, 1.02 ng/mL; its five metabolites, 0.100-0.113 ng/mL; and MET, 4.95 ng/mL. The LLOQ in urine samples was 0.0594 ng/mL for GLB, 0.984-1.02 ng/mL for its five metabolites and 30.0 µg/mL for MET. The relative deviation of this method was <14% for intra-day and inter-day assays in plasma and urine samples, and the accuracy was 86-114% in plasma, and 94-105% in urine. The method described in this report was successfully utilized for determining the concentrations of the two medications in patient plasma and urine. Copyright © 2014 John Wiley & Sons, Ltd.

  5. Quantitative determination of metformin, glyburide and its metabolites in plasma and urine of pregnant patients by LC-MS/MS

    PubMed Central

    Zhang, Xing; Wang, Xiaoming; Vernikovskaya, Daria I.; Fokina, Valentina M.; Nanovskaya, Tatiana N.; Hankins, Gary D.V.; Ahmed, Mahmoud S.

    2014-01-01

    This report describes the development and validation of an LC-MS/MS method for the quantitative determination of glyburide (GLB), its five metabolites (M1, M2a, M2b, M3, and M4) and metformin (MET) in plasma and urine of pregnant patients under treatment with a combination of the two medications. The extraction recovery of the analytes from plasma samples ranged between 87% and 99%, and 85%–95% for urine samples. The differences in retention times among the analytes, and the wide range of the concentrations of the medications and their metabolites in plasma and urine patient samples required the development of three LC methods. The lower limit of quantitation (LLOQ) of the analytes in plasma samples was as follows: GLB, 1.02 ng/mL; its five metabolites, 0.100–0.113 ng/mL and 4.95 ng/mL for MET. LLOQ in urine samples was 0.0594 ng/mL for GLB, 0.984–1.02 ng/mL for its five metabolites and 30.0 μg/mL for MET. The relative deviation of this method was < 14% for intra-day and inter-day assays in plasma and urine samples, and the accuracy ranged between 86% and 114% in plasma, and 94% to 105% in urine. The method described in this report was successfully utilized for determining the concentrations of the two medications in patient plasma and urine. PMID:25164921

  6. Simultaneous quantification of acetaminophen and five acetaminophen metabolites in human plasma and urine by high-performance liquid chromatography-electrospray ionization-tandem mass spectrometry: Method validation and application to a neonatal pharmacokinetic study.

    PubMed

    Cook, Sarah F; King, Amber D; van den Anker, John N; Wilkins, Diana G

    2015-12-15

    Drug metabolism plays a key role in acetaminophen (paracetamol)-induced hepatotoxicity, and quantification of acetaminophen metabolites provides critical information about factors influencing susceptibility to acetaminophen-induced hepatotoxicity in clinical and experimental settings. The aims of this study were to develop, validate, and apply high-performance liquid chromatography-electrospray ionization-tandem mass spectrometry (HPLC-ESI-MS/MS) methods for simultaneous quantification of acetaminophen, acetaminophen-glucuronide, acetaminophen-sulfate, acetaminophen-glutathione, acetaminophen-cysteine, and acetaminophen-N-acetylcysteine in small volumes of human plasma and urine. In the reported procedures, acetaminophen-d4 and acetaminophen-d3-sulfate were utilized as internal standards (IS). Analytes and IS were recovered from human plasma (10μL) by protein precipitation with acetonitrile. Human urine (10μL) was prepared by fortification with IS followed only by sample dilution. Calibration concentration ranges were tailored to literature values for each analyte in each biological matrix. Prepared samples from plasma and urine were analyzed under the same HPLC-ESI-MS/MS conditions, and chromatographic separation was achieved through use of an Agilent Poroshell 120 EC-C18 column with a 20-min run time per injected sample. The analytes could be accurately and precisely quantified over 2.0-3.5 orders of magnitude. Across both matrices, mean intra- and inter-assay accuracies ranged from 85% to 112%, and intra- and inter-assay imprecision did not exceed 15%. Validation experiments included tests for specificity, recovery and ionization efficiency, inter-individual variability in matrix effects, stock solution stability, and sample stability under a variety of storage and handling conditions (room temperature, freezer, freeze-thaw, and post-preparative). The utility and suitability of the reported procedures were illustrated by analysis of pharmacokinetic samples collected from neonates receiving intravenous acetaminophen. Copyright © 2015 Elsevier B.V. All rights reserved.

  7. Detection of Elevated Plasma Levels of EGF Receptor Prior to Breast Cancer Diagnosis among Hormone Therapy Users

    PubMed Central

    Pitteri, Sharon J.; Amon, Lynn M.; Buson, Tina Busald; Zhang, Yuzheng; Johnson, Melissa M.; Chin, Alice; Kennedy, Jacob; Wong, Chee-Hong; Zhang, Qing; Wang, Hong; Lampe, Paul D.; Prentice, Ross L.; McIntosh, Martin W.; Hanash, Samir M.; Li, Christopher I.

    2010-01-01

    Applying advanced proteomic technologies to prospectively collected specimens from large studies is one means of identifying preclinical changes in plasma proteins that are potentially relevant to the early detection of diseases like breast cancer. We conducted fourteen independent quantitative proteomics experiments comparing pooled plasma samples collected from 420 estrogen receptor positive (ER+) breast cancer patients ≤17 months prior to their diagnosis and matched controls. Based on the over 3.4 million tandem mass spectra collected in the discovery set, 503 proteins were quantified of which 57 differentiated cases from controls with a p-value<0.1. Seven of these proteins, for which quantitative ELISA assays were available, were assessed in an independent validation set. Of these candidates, epidermal growth factor receptor (EGFR) was validated as a predictor of breast cancer risk in an independent set of preclinical plasma samples for women overall [odds ratio (OR)=1.44, p-value=0.0008], and particularly for current users of estrogen plus progestin (E+P) menopausal hormone therapy (OR=2.49, p-value=0.0001). Among current E+P users EGFR's sensitivity for breast cancer risk was 31% with 90% specificity. While EGFR's sensitivity and specificity are insufficient for a clinically useful early detection biomarker, this study suggests that proteins that are elevated preclinically in women who go on to develop breast cancer can be discovered and validated using current proteomic technologies. Further studies are warranted to both examine the role of EGFR and to discover and validate other proteins that could potentially be used for breast cancer early detection. PMID:20959476

  8. Lack of reliability of nanotechnology in the of free plasma DNA in samples of patients with prostate cancer

    PubMed Central

    2013-01-01

    Background Several studies seek biological markers that give diagnostic and degree of tumor development. The aim of this study was to validate the determination of plasma DNA using nanotechnology (Nanovue™-NV) in samples of 80 patients with prostate cancer. Methods Blood samples of 80 patients of the Urology Ambulatory of Faculdade de Medicina do ABC with prostate cancer confirmed by anatomical-pathology criteria were analyzed. DNA extraction was performed using a GFX TM kit (Amersham Pharmacia Biotech, Inc, USA) following the adapted protocol. Plasma was subjected to centrifugation. Results There was a big difference between the first and the second value obtained by NanoVue Only two samples had no differences between duplicates. Maximum difference between duplicates was 38 μg/mL. Average variation between 51 samples was 10.29 μg/mL, although 21 samples had differences above this average. No correlation was observed between pDNA obtained by traditional spectrophotometry and by nanotechnology. Conclusion Determination of plasma DNA by nanotechnology was not reproducible. PMID:23311763

  9. Validation of an assay for quantification of free normetanephrine, metanephrine and methoxytyramine in plasma by high performance liquid chromatography with coulometric detection: Comparison of peak-area vs. peak-height measurements.

    PubMed

    Nieć, Dawid; Kunicki, Paweł K

    2015-10-01

    Measurements of plasma concentrations of free normetanephrine (NMN), metanephrine (MN) and methoxytyramine (MTY) constitute the most diagnostically accurate screening test for pheochromocytomas and paragangliomas. The aim of this article is to present the results from a validation of an analytical method utilizing high performance liquid chromatography with coulometric detection (HPLC-CD) for quantifying plasma free NMN, MN and MTY. Additionally, peak integration by height and area and the use of one calibration curve for all batches or individual calibration curve for each batch of samples was explored as to determine the optimal approach with regard to accuracy and precision. The method was validated using charcoal stripped plasma spiked with solutions of NMN, MN, MTY and internal standard (4-hydroxy-3-methoxybenzylamine) with the exception of selectivity which was evaluated by analysis of real plasma samples. Calibration curve performance, accuracy, precision and recovery were determined following both peak-area and peak-height measurements and the obtained results were compared. The most accurate and precise method of calibration was evaluated by analyzing quality control samples at three concentration levels in 30 analytical runs. The detector response was linear over the entire tested concentration range from 10 to 2000pg/mL with R(2)≥0.9988. The LLOQ was 10pg/mL for each analyte of interest. To improve accuracy for measurements at low concentrations, a weighted (1/amount) linear regression model was employed, which resulted in inaccuracies of -2.48 to 9.78% and 0.22 to 7.81% following peak-area and peak-height integration, respectively. The imprecisions ranged from 1.07 to 15.45% and from 0.70 to 11.65% for peak-area and peak-height measurements, respectively. The optimal approach to calibration was the one utilizing an individual calibration curve for each batch of samples and peak-height measurements. It was characterized by inaccuracies ranging from -3.39 to +3.27% and imprecisions from 2.17 to 13.57%. The established HPLC-CD method enables accurate and precise measurements of plasma free NMN, MN and MTY with reasonable selectivity. Preparing calibration curve based on peak-height measurements for each batch of samples yields optimal accuracy and precision. Copyright © 2015. Published by Elsevier B.V.

  10. Assay of free captopril in human plasma as monobromobimane derivative, using RPLC/(+)ESI/MS/MS: validation aspects and bioequivalence evaluation.

    PubMed

    Medvedovici, Andrei; Albu, Florin; Sora, Iuliana Daniela; Udrescu, Stefan; Galaon, Toma; David, Victor

    2009-10-01

    A sensitive method for determination of free captopril as monobromobimane derivative in plasma samples is discussed. The internal standard (IS) was 5-methoxy-1H-benzimidazole-2-thiol. Derivatization with monobromobimane immediately after blood collection and plasma preparation prevents oxidation of captopril to the corresponding disulfide compound and enhances the ionization yield. Consequently, derivatization enhances sample stability and detection sensitivity. Addition of the internal standard was made immediately after plasma preparation. The internal standard was also derivatized by monobromobimane, as it contains a thiol functional group. Preparation of plasma samples containing captopril and IS derivatives was based upon protein precipitation through addition of acetonitrile, in a volumetric ratio 1:2. The reversed-phase liquid chromatographic separation was achieved on a rapid resolution cartridge Zorbax SB-C(18), monitored through positive electrospray ionization and tandem MS detection using the multiple-reaction monitoring mode. Transitions were 408-362 amu for the captopril derivative and 371-260 amu for the internal standard derivative. The kinetics of captopril oxidation to the corresponding disulfide compound in plasma matrix was also studied using the proposed method. A linear log-log calibration was obtained over the concentration interval 2.5-750 ng/mL. A low limit of quantitation in the 2.5 ng/mL range was obtained. The analytical method was fully validated and successfully applied in a three-way, three-period, single-dose (50 mg), block-randomized bioequivalence study for two pharmaceutical formulations (captopril LPH 25 and 50 mg) against the comparator Capoten 50 mg. Copyright (c) 2009 John Wiley & Sons, Ltd.

  11. Standardization and validation of a cytometric bead assay to assess antibodies to multiple Plasmodium falciparum recombinant antigens.

    PubMed

    Ondigo, Bartholomew N; Park, Gregory S; Gose, Severin O; Ho, Benjamin M; Ochola, Lyticia A; Ayodo, George O; Ofulla, Ayub V; John, Chandy C

    2012-12-21

    Multiplex cytometric bead assay (CBA) have a number of advantages over ELISA for antibody testing, but little information is available on standardization and validation of antibody CBA to multiple Plasmodium falciparum antigens. The present study was set to determine optimal parameters for multiplex testing of antibodies to P. falciparum antigens, and to compare results of multiplex CBA to ELISA. Antibodies to ten recombinant P. falciparum antigens were measured by CBA and ELISA in samples from 30 individuals from a malaria endemic area of Kenya and compared to known positive and negative control plasma samples. Optimal antigen amounts, monoplex vs multiplex testing, plasma dilution, optimal buffer, number of beads required were assessed for CBA testing, and results from CBA vs. ELISA testing were compared. Optimal amounts for CBA antibody testing differed according to antigen. Results for monoplex CBA testing correlated strongly with multiplex testing for all antigens (r = 0.88-0.99, P values from <0.0001 - 0.004), and antibodies to variants of the same antigen were accurately distinguished within a multiplex reaction. Plasma dilutions of 1:100 or 1:200 were optimal for all antigens for CBA testing. Plasma diluted in a buffer containing 0.05% sodium azide, 0.5% polyvinylalcohol, and 0.8% polyvinylpyrrolidone had the lowest background activity. CBA median fluorescence intensity (MFI) values with 1,000 antigen-conjugated beads/well did not differ significantly from MFI with 5,000 beads/well. CBA and ELISA results correlated well for all antigens except apical membrane antigen-1 (AMA-1). CBA testing produced a greater range of values in samples from malaria endemic areas and less background reactivity for blank samples than ELISA. With optimization, CBA may be the preferred method of testing for antibodies to P. falciparum antigens, as CBA can test for antibodies to multiple recombinant antigens from a single plasma sample and produces a greater range of values in positive samples and lower background readings for blank samples than ELISA.

  12. Simultaneous quantification of the organophosphorus pesticides dimethoate and omethoate in porcine plasma and urine by LC-ESI-MS/MS and flow-injection-ESI-MS/MS.

    PubMed

    John, Harald; Eddleston, Michael; Clutton, R Eddie; Worek, Franz; Thiermann, Horst

    2010-05-15

    Dimethoate is an organophosphorus toxicant used in agri- and horticulture as a systemic broad-spectrum insecticide. It also exhibits toxic activity towards mammalian organism provoked by catalytic desulfuration in the liver producing its oxon-derivative omethoate thus inhibiting acetylcholinesterase, initiating cholinergic crisis and ultimately leading to death by respiratory paralysis and cardiovascular collapse. Pharmaco- and toxicokinetic studies in animal models help to broaden basic understanding of medical intervention by antidotes and supportive care. Therefore, we developed and validated a LC-ESI-MS/MS method suitable for the simultaneous, selective, precise (RSD(intra-day) 1-8%; RSD(inter-day) 5-14%), accurate (intra-day: 95-107%; inter-day: 90-115%), and robust quantification of both pesticides from porcine urine and plasma after deproteinization by precipitation and extensive dilution (1:11,250 for plasma and 1:40,000 for urine). Accordingly, lower limits of quantification (0.24-0.49 microg/ml plasma and 0.78-1.56 microg/ml urine) and lower limits of detection (0.12-0.24 microg/ml plasma and 0.39-0.78 microg/ml urine) were equivalent to quite low absolute on-column amounts (1.1-2.1 pg for plasma and 2.0-3.9 pg for urine). The calibration range (0.24-250 microg/ml plasma and 0.78-200 microg/ml urine) was subdivided into two linear ranges (r(2)>or=0.998) each covering nearly two orders of magnitude. The lack of any interfering peak in 6 individual blank specimens from plasma and urine demonstrated the high selectivity of the method. Furthermore, extensive sample dilution causing lowest concentration of potentially interfering matrix ingredients prompted us to develop and validate an additional flow-injection method (FI-ESI-MS/MS). Validation characteristics were as good as for the chromatographic method but sample throughput was enhanced by a factor of 6. Effects on ionization provoked by plasma and urine matrix from 6 individuals as well as in the presence of therapeutics (antidotes) administered in an animal study were investigated systematically underlying in the reliability of the presented methods. Both methods were applied to porcine samples derived from an in vivo animal study. Copyright (c) 2010 Elsevier B.V. All rights reserved.

  13. Analysis of human plasma proteins: a focus on sample collection and separation using free-flow electrophoresis.

    PubMed

    Nissum, Mikkel; Foucher, Aude L

    2008-08-01

    Due to ease of accessibility, plasma has become the sample of choice for proteomics studies directed towards biomarker discovery intended for use in diagnostics, prognostics and even in theranostics. The result of these extensive efforts is a long list of potential biomarkers, very few of which have led to clinical utility. Why have so many potential biomarkers failed validation? Herein, we address certain issues encountered, which complicate biomarker discovery efforts originating from plasma. The advantages of stabilizing the sample at collection by the addition of protease inhibitors are discussed. The principles of free-flow electrophoresis (FFE) separation are provided together with examples applying to various studies. Finally, particular attention is given to plasma or serum analysis using multidimensional separation strategies into which the FFE is incorporated. The advantages of using FFE separation in these workflows are discussed.

  14. Development and validation of a liquid chromatography-tandem mass spectrometry method for the determination of pyridostigmine bromide from guinea pig plasma.

    PubMed

    Needham, Shane R; Ye, Binying; Smith, J Richard; Korte, William D

    2003-11-05

    An HPLC/MS/MS method was validated for the low level analysis of pyridostigmine bromide (PB) from guinea pig plasma. An advantage of this strong-cation exchange HPLC/MS/MS method was the enhancement of the ESI-MS signal by providing good retention and good peak shape of PB with a mobile phase of 70% acetonitrile. In addition, the use of 70% acetonitrile in the mobile phase allowed the direct injection of the supernant from the protein precipitated extracted sample. The assay was linear from the range of 0.1 to 50 ng/ml using only 25 microl of sample. The precision and accuracy of the assay was better than 9.1 and 113%, respectively.

  15. Development and validation of a liquid chromatography-tandem mass spectrometry analytical method for the therapeutic drug monitoring of eight novel anticancer drugs.

    PubMed

    Herbrink, M; de Vries, N; Rosing, H; Huitema, A D R; Nuijen, B; Schellens, J H M; Beijnen, J H

    2018-04-01

    To support therapeutic drug monitoring of patients with cancer, a fast and accurate method for simultaneous quantification of the registered anticancer drugs afatinib, axitinib, ceritinib, crizotinib, dabrafenib, enzalutamide, regorafenib and trametinib in human plasma using liquid chromatography tandem mass spectrometry was developed and validated. Human plasma samples were collected from treated patients and stored at -20°C. Analytes and internal standards (stable isotopically labeled analytes) were extracted with acetonitrile. An equal amount of 10 mm NH 4 CO 3 was added to the supernatant to yield the final extract. A 2 μL aliquot of this extract was injected onto a C 18 -column, gradient elution was applied and triple-quadrupole mass spectrometry in positive-ion mode was used for detection. All results were within the acceptance criteria of the latest US Food and Drug Administration guidance and European Medicines Agency guidelines on method validation, except for the carry-over of ceritinib and crizotinib. These were corrected for by the injection order of samples. Additional stability tests were carried out for axitinib and dabrafenib in relation to their reported photostability. In conclusion, the described method to simultaneously quantify the eight selected anticancer drugs in human plasma was successfully validated and applied for therapeutic drug monitoring in cancer patients treated with these drugs. Copyright © 2017 John Wiley & Sons, Ltd.

  16. Development and Validation of a Sensitive LC-MS/MS Method for the Determination of Fenoterol in Human Plasma and Urine Samples

    PubMed Central

    Sanghvi, M.; Ramamoorthy, A.; Strait, J.; Wainer, I. W.; Moaddel, R.

    2013-01-01

    Due to the lack of sensitivity in current methods for the determination of fenoterol (Fen). A rapid, LC-MS/MS method was developed for the determination of (R,R′)-Fen and (R,R′;S,S′)-Fen in plasma and urine. The method was fully validated and was linear from 50 pg/ml to 2000 pg/ml for plasma and from 2.500 ng/ml to 160 ng/ml for urine with a lower limit of quantitation of 52.8 pg/ml in plasma. The coefficient of variation was <15% for the high QC standards and <10% for the low QC standards in plasma and was <15% for the high and low QC standards in urine. The relative concentrations of (R,R′)-Fen and (S,S′)-Fen were determined using a chirobiotic T chiral stationary phase. The method was used to determine the concentration of (R,R′)-Fen in plasma and urine samples obtained in an oral cross-over study of (R,R′)-Fen and (R,R′;S,S′)-Fen formulations. The results demonstrated a potential pre-systemic enantioselective interaction in which the (S,S′)-Fen reduces the sulfation of the active (R,R′)-Fen. The data suggests that a non-racemic mixture of the Fen enantiomers may provide better bioavailability of the active (R,R′)-Fen for use in the treatment of cardiovascular disease PMID:23872161

  17. Determination of tafenoquine in dried blood spots and plasma using LC and fluorescence detection.

    PubMed

    Römsing, Susanne; Lindegardh, Niklas; Bergqvist, Yngve

    2011-08-01

    The growing problem of parasites developing resistance to the traditional antimalarial drugs makes the development of new effective and safe drugs crucial. Tafenoquine is a new promising antimalarial drug for prophylaxis and treatment. A bioanalytical method for the determination of tafenoquine in 100 µl of capillary blood applied onto sampling paper and in 100 µl of plasma has been developed and validated. The Whatman 31 ET Chr paper was treated with 0.6 mol/l tartaric acid to improve the extraction recovery and solid-phase extraction was used for cleanup procedure of the blood samples. Plasma samples were precipitated with methanol. Tafenoquine and internal standard were separated on a Zorbax SB-CN column by reversed-phase LC and detected with fluorescence detection at 262 and 470 nm. The within- and between-day variations were below 10 and 14%, respectively, over the range 50-200 nmol/l for capillary blood on sampling paper and below 6 and 10% for plasma samples. The LLOQ of the method was 50 nmol/l. The developed method has adequate sensitivity and is highly suitable for clinical studies in dried blood spots and plasma.

  18. Drug use in pregnant women-a pilot study of the coherence between reported use of drugs and presence of drugs in plasma.

    PubMed

    Wolgast, Emelie; Josefsson, Ann; Josefsson, Martin; Lilliecreutz, Caroline; Reis, Margareta

    2018-04-01

    In Sweden, information on drug use during pregnancy is obtained through an interview and recorded in a standardized medical record at every visit to the antenatal care clinic throughout the pregnancy. Antenatal, delivery, and neonatal records constitute the basis for the Swedish Medical Birth Register (MBR). The purpose of this exploratory study was to investigate the reliability of reported drug use by simultaneous screening for drug substances in the blood stream of the pregnant woman and thereby validate self-reported data in the MBR. Plasma samples from 200 women were obtained at gestational weeks 10-12 and 25 and screened for drugs by using ultra-high performance liquid chromatography with time of flight mass spectrometry (UHPLC-TOF-MS). The results from the analysis were then compared to medical records. At the first sampling occasion, the drugs found by screening had been reported by 86% of the women and on the second sampling, 85.5%. Missed reported information was clearly associated with drugs for occasional use. The most common drugs in plasma taken in early and mid-pregnancy were meclizine and paracetamol. Two types of continuously used drugs, selective serotonin reuptake inhibitors and propranolol, were used. All women using them reported it and the drug screening revealed a 100% coherence. This study shows good coherence between reported drug intake and the drugs found in plasma samples, which in turn positively validates the MBR.

  19. Application of proteomics in the discovery of candidate protein biomarkers in a Diabetes Autoantibody Standardization Program (DASP) sample subset

    PubMed Central

    Metz, Thomas O.; Qian, Wei-Jun; Jacobs, Jon M.; Gritsenko, Marina A.; Moore, Ronald J.; Polpitiya, Ashoka D.; Monroe, Matthew E.; Camp, David G.; Mueller, Patricia W.; Smith, Richard D.

    2009-01-01

    Novel biomarkers of type 1 diabetes must be identified and validated in initial, exploratory studies before they can be assessed in proficiency evaluations. Currently, untargeted “-omics” approaches are under-utilized in profiling studies of clinical samples. This report describes the evaluation of capillary liquid chromatography (LC) coupled with mass spectrometry (MS) in a pilot proteomic analysis of human plasma and serum from a subset of control and type 1 diabetic individuals enrolled in the Diabetes Autoantibody Standardization Program with the goal of identifying candidate biomarkers of type 1 diabetes. Initial high-resolution capillary LC-MS/MS experiments were performed to augment an existing plasma peptide database, while subsequent LC-FTICR studies identified quantitative differences in the abundance of plasma proteins. Analysis of LC-FTICR proteomic data identified five candidate protein biomarkers of type 1 diabetes. Alpha-2-glycoprotein 1 (zinc), corticosteroid-binding globulin, and lumican were 2-fold up-regulated in type 1 diabetic samples relative to control samples, whereas clusterin and serotransferrin were 2-fold up-regulated in control samples relative to type 1 diabetic samples. Observed perturbations in the levels of all five proteins are consistent with the metabolic aberrations found in type 1 diabetes. While the discovery of these candidate protein biomarkers of type 1 diabetes is encouraging, follow up studies are required for validation in a larger population of individuals and for determination of laboratory-defined sensitivity and specificity values using blinded samples. PMID:18092746

  20. Application of proteomics in the discovery of candidate protein biomarkers in a diabetes autoantibody standardization program sample subset.

    PubMed

    Metz, Thomas O; Qian, Wei-Jun; Jacobs, Jon M; Gritsenko, Marina A; Moore, Ronald J; Polpitiya, Ashoka D; Monroe, Matthew E; Camp, David G; Mueller, Patricia W; Smith, Richard D

    2008-02-01

    Novel biomarkers of type 1 diabetes must be identified and validated in initial, exploratory studies before they can be assessed in proficiency evaluations. Currently, untargeted "-omics" approaches are underutilized in profiling studies of clinical samples. This report describes the evaluation of capillary liquid chromatography (LC) coupled with mass spectrometry (MS) in a pilot proteomic analysis of human plasma and serum from a subset of control and type 1 diabetic individuals enrolled in the Diabetes Autoantibody Standardization Program, with the goal of identifying candidate biomarkers of type 1 diabetes. Initial high-resolution capillary LC-MS/MS experiments were performed to augment an existing plasma peptide database, while subsequent LC-FTICR studies identified quantitative differences in the abundance of plasma proteins. Analysis of LC-FTICR proteomic data identified five candidate protein biomarkers of type 1 diabetes. alpha-2-Glycoprotein 1 (zinc), corticosteroid-binding globulin, and lumican were 2-fold up-regulated in type 1 diabetic samples relative to control samples, whereas clusterin and serotransferrin were 2-fold up-regulated in control samples relative to type 1 diabetic samples. Observed perturbations in the levels of all five proteins are consistent with the metabolic aberrations found in type 1 diabetes. While the discovery of these candidate protein biomarkers of type 1 diabetes is encouraging, follow up studies are required for validation in a larger population of individuals and for determination of laboratory-defined sensitivity and specificity values using blinded samples.

  1. Enhanced high-performance liquid chromatography method for the determination of retinoic acid in plasma. Development, optimization and validation.

    PubMed

    Teglia, Carla M; Gil García, María D; Galera, María Martínez; Goicoechea, Héctor C

    2014-08-01

    When determining endogenous compounds in biological samples, the lack of blank or analyte-free matrix samples involves the use of alternative strategies for calibration and quantitation. This article deals with the development, optimization and validation of a high performance liquid chromatography method for the determination of retinoic acid in plasma, obtaining at the same time information about its isomers, taking into account the basal concentration of these endobiotica. An experimental design was used for the optimization of three variables: mobile phase composition, flow rate and column temperature through a central composite design. Four responses were selected for optimization purposes (area under the peaks, quantity of peaks, analysis time and resolution between the first principal peak and the following one). The optimum conditions resulted in a mobile phase consisting of methanol 83.4% (v/v), acetonitrile 0.6% (v/v) and acid aqueous solution 16.0% (v/v); flow rate of 0.68 mL min(-1) and an column temperature of 37.10 °C. Detection was performed at 350 nm by a diode array detector. The method was validated following a holistic approach that included not only the classical parameters related to method performance but also the robustness and the expected proportion of acceptable results lying inside predefined acceptability intervals, i.e., the uncertainty of measurements. The method validation results indicated a high selectivity and good precision characteristics that were studied at four concentration levels, with RSD less than 5.0% for retinoic acid (less than 7.5% for the LOQ concentration level), in intra and inter-assay precision studies. Linearity was proved for a range from 0.00489 to 15.109 ng mL(-1) of retinoic acid and the recovery, which was studied at four different fortification levels in phuman plasma samples, varied from 99.5% to 106.5% for retinoic acid. The applicability of the method was demonstrated by determining retinoic acid and obtaining information about its isomers in human and frog plasma samples from different origins. Copyright © 2014 Elsevier B.V. All rights reserved.

  2. IV busulfan dose individualization in children undergoing hematopoietic stem cell transplant: limited sampling strategies.

    PubMed

    Dupuis, L Lee; Sibbald, Cathryn; Schechter, Tal; Ansari, Marc; Gassas, Adam; Théorêt, Yves; Kassir, Nastya; Champagne, Martin A; Doyle, John

    2008-05-01

    We currently calculate area under the busulfan concentration time curve (AUC) using 7 plasma busulfan concentrations (AUC7) drawn after the first of 16 i.v. busulfan doses given as a 2-hour infusion every 6 hours. The aim of this study was to develop and validate limited sampling strategies (LSSs) using 3 or fewer busulfan concentration values with which to reliably calculate AUC in children undergoing hematopoietic stem cell transplant (HSCT). Children in the development group (44) received i.v. busulfan at Sick Kids; the validation group consisted of 35 children who received care at CHU Ste-Justine. Busulfan doses given and subsequent plasma busulfan concentrations were recorded. LSSs using 1 to 3 concentration-time points were developed using multiple linear regression. LSS were considered to be acceptable when adjusted r(2) > 0.9, mean bias <15% and precision <15%. Extent of agreement between the AUC7 values and the LSS AUC was assessed by the intraclass correlation coefficient (ICC) and Bland-Altman (BA) analysis. Agreement was considered to be excellent when the lower limit of the 95% confidence limit of the ICC exceeded 0.9 and when the limits of agreement in the BA analysis were +/-15% for both AUC and dose. Administration of the theoretic adjusted busulfan doses based on each LSS was simulated and cases where the resulting AUC was >1500 or <900 microM x min were noted. LSSs using 1, 2, or 3 plasma busulfan concentrations were developed that showed excellent agreement with AUC7 and adjusted busulfan doses. In the validation sample, only the 2- and 3-point LSSs demonstrated acceptable precision and lack of bias. LSSs using 2 or 3 plasma busulfan concentrations can be used to reliably estimate busulfan AUC after IV administration in children undergoing HSCT.

  3. Sensitive Detection of Colorectal Cancer in Peripheral Blood by Septin 9 DNA Methylation Assay

    PubMed Central

    Grützmann, Robert; Molnar, Bela; Pilarsky, Christian; Habermann, Jens K.; Schlag, Peter M.; Saeger, Hans D.; Miehlke, Stephan; Stolz, Thomas; Model, Fabian; Roblick, Uwe J.; Bruch, Hans-Peter; Koch, Rainer; Liebenberg, Volker; deVos, Theo; Song, Xiaoling; Day, Robert H.; Sledziewski, Andrew Z.; Lofton-Day, Catherine

    2008-01-01

    Background Colorectal cancer (CRC) is the second leading cause of cancer deaths despite the fact that detection of this cancer in early stages results in over 90% survival rate. Currently less than 45% of at-risk individuals in the US are screened regularly, exposing a need for better screening tests. We performed two case-control studies to validate a blood-based test that identifies methylated DNA in plasma from all stages of CRC. Methodology/Principal Findings Using a PCR assay for analysis of Septin 9 (SEPT9) hypermethylation in DNA extracted from plasma, clinical performance was optimized on 354 samples (252 CRC, 102 controls) and validated in a blinded, independent study of 309 samples (126 CRC, 183 controls). 168 polyps and 411 additional disease controls were also evaluated. Based on the training study SEPT9-based classification detected 120/252 CRCs (48%) and 7/102 controls (7%). In the test study 73/126 CRCs (58%) and 18/183 control samples (10%) were positive for SEPT9 validating the training set results. Inclusion of an additional measurement replicate increased the sensitivity of the assay in the testing set to 72% (90/125 CRCs detected) while maintaining 90% specificity (19/183 for controls). Positive rates for plasmas from the other cancers (11/96) and non-cancerous conditions (41/315) were low. The rate of polyp detection (>1 cm) was ∼20%. Conclusions/Significance Analysis of SEPT9 DNA methylation in plasma represents a straightforward, minimally invasive method to detect all stages of CRC with potential to satisfy unmet needs for increased compliance in the screening population. Further clinical testing is warranted. PMID:19018278

  4. Simple validated LC-MS/MS method for the determination of atropine and scopolamine in plasma for clinical and forensic toxicological purposes.

    PubMed

    Koželj, Gordana; Perharič, Lucija; Stanovnik, Lovro; Prosen, Helena

    2014-08-05

    A liquid chromatography-tandem mass spectrometry (LC-MS/MS) method for the determination of atropine and scopolamine in 100μL human plasma was developed and validated. Sample pretreatment consisted of protein precipitation with acetonitrile followed by a concentration step. Analytes and levobupivacaine (internal standard) were separated on a Zorbax XDB-CN column (75mm×4.6mm i.d., 3.5μm) with gradient elution (purified water, acetonitrile, formic acid). The triple quadrupole MS was operated in ESI positive mode. Matrix effect was estimated for deproteinised plasma samples. Selected reaction monitoring (SRM) was used for quantification in the range of 0.10-50.00ng/mL. Interday precision for both tropanes and intraday precision for atropine was <10%, intraday precision for scopolamine was <14% and <18% at lower limit of quantification (LLOQ). Mean interday and intraday accuracies for atropine were within ±7% and for scopolamine within ±11%. The method can be used for determination of therapeutic and toxic levels of both compounds and has been successfully applied to a study of pharmacodynamic and pharmacokinetic properties of tropanes, where plasma samples of volunteers were collected at fixed time intervals after ingestion of a buckwheat meal, spiked with five low doses of tropanes. Copyright © 2014 Elsevier B.V. All rights reserved.

  5. Human exposure to Bisphenol A and liver health status: Quantification of urinary and circulating levels by LC-MS/MS.

    PubMed

    Nicolucci, Carla; Errico, Sonia; Federico, Alessandro; Dallio, Marcello; Loguercio, Carmelina; Diano, Nadia

    2017-06-05

    A selective and highly sensitive analytical methodology for determination of Bisphenol A in human plasma was developed and validated. The method was based on selective liquid/solid extraction, combined with liquid chromatography-electrospray ionization tandem mass spectrometry in the multiple reaction monitoring mode and negative ionization. The linearity of the detector response was verified in human plasma over the concentration range 0.100-200ngmL -1 . The detection limit was 0.03ngmL -1 and the quantification limit was 0.100ngmL -1 . The analytical features of the proposed in-house validated method were satisfactory: precision was <10% and recoveries were around 84-104%. The matrix effect was studied and compensated using deuterated labeled standard. The applicability of the proposed method was demonstrated analyzing human plasma samples from individuals affected by non-alcoholic fatty liver disease. Bisphenol A was detected above the detection limit in all samples. The data show a persistence of unconjugated Bisphenol A levels in plasma and indicate a chronic Bisphenol A exposure of the target organ, suggesting an association between liver health status and Bisphenol A exposure. The results from our study are valuable for further investigation with large sample size and longitudinal study designs, necessary to confirm the observed association. Copyright © 2017 Elsevier B.V. All rights reserved.

  6. Fully automated methods for the determination of hydrochlorothiazide in human plasma and urine.

    PubMed

    Hsieh, J Y; Lin, C; Matuszewski, B K; Dobrinska, M R

    1994-12-01

    LC assays utilizing fully automated sample preparation procedures on Zymark PyTechnology Robot and BenchMate Workstation for the quantification of hydrochlorothiazide (HCTZ) in human plasma and urine have been developed. After aliquoting plasma and urine samples, and adding internal standard (IS) manually, the robot executed buffer and organic solvent addition, liquid-liquid extraction, solvent evaporation and on-line LC injection steps for plasma samples, whereas, BenchMate performed buffer and organic solvent addition, liquid-liquid and solid-phase extractions, and on-line LC injection steps for urine samples. Chromatographic separations were carried out on Beckman Octyl Ultrasphere column using the mobile phase composed of 12% (v/v) acetonitrile and 88% of either an ion-pairing reagent (plasma) or 0.1% trifluoroacetic acid (urine). The eluent from the column was monitored with UV detector (271 nm). Peak heights for HCTZ and IS were automatically processed using a PE-Nelson ACCESS*CHROM laboratory automation system. The assays have been validated in the concentration range of 2-100 ng ml-1 in plasma and 0.1-20 micrograms ml-1 in urine. Both plasma and urine assays have the sensitivity and specificity necessary to determine plasma and urine concentrations of HCTZ from low dose (6.25/12.5 mg) administration of HCTZ to human subjects in the presence or absence of losartan.

  7. Clinical Validation of Therapeutic Drug Monitoring of Imipenem in Spent Effluent in Critically Ill Patients Receiving Continuous Renal Replacement Therapy: A Pilot Study.

    PubMed

    Wen, Aiping; Li, Zhe; Yu, Junxian; Li, Ren; Cheng, Sheng; Duan, Meili; Bai, Jing

    2016-01-01

    The primary objective of this pilot study was to investigate whether the therapeutic drug monitoring of imipenem could be performed with spent effluent instead of blood sampling collected from critically ill patients under continuous renal replacement therapy. A prospective open-label study was conducted in a real clinical setting. Both blood and effluent samples were collected pairwise before imipenem administration and 0.5, 1, 1.5, 2, 3, 4, 6, and 8 h after imipenem administration. Plasma and effluent imipenem concentrations were determined by reversed-phase high-performance liquid chromatography with ultraviolet detection. Pharmacokinetic and pharmacodynamic parameters of blood and effluent samples were calculated. Eighty-three paired plasma and effluent samples were obtained from 10 patients. The Pearson correlation coefficient of the imipenem concentrations in plasma and effluent was 0.950 (P<0.0001). The average plasma-to-effluent imipenem concentration ratio was 1.044 (95% confidence interval, 0.975 to 1.114) with Bland-Altman analysis. No statistically significant difference was found in the pharmacokinetic and pharmacodynamic parameters tested in paired plasma and effluent samples with Wilcoxon test. Spent effluent of continuous renal replacement therapy could be used for therapeutic drug monitoring of imipenem instead of blood sampling in critically ill patients.

  8. Charge-exchange plasma generated by an ion thruster

    NASA Technical Reports Server (NTRS)

    Kaufman, H. R.

    1977-01-01

    The charge exchange plasma generated by an ion thruster was investigated experimentally using both 5 cm and 15 cm thrusters. Results are shown for wide ranges of radial distance from the thruster and angle from the beam direction. Considerations of test environment, as well as distance from the thruster, indicate that a valid simulation of a thruster on a spacecraft was obtained. A calculation procedure and a sample calculation of charge exchange plasma density and saturation electron current density are included.

  9. A novel, simple and inexpensive procedure for the simultaneous determination of iopamidol and p-aminohippuric acid for renal function assessment from plasma samples in awake rats.

    PubMed

    Rodríguez-Romero, Violeta; González-Villalva, Karla I; Reyes, José L; Franco-Bourland, Rebecca E; Guízar-Sahagún, Gabriel; Castañeda-Hernández, Gilberto; Cruz-Antonio, Leticia

    2015-03-25

    The purpose of the current study was to design, validate and implement a novel analytical method for the simultaneous plasma measurement of iopamidol and p-aminohippuric acid (PAH) to estimate renal function in awake rats. A reverse-phase high performance liquid chromatographic (RP-HPLC) method for the simultaneous measurement of iopamidol (for glomerular filtration rate estimation, GFR) and PAH (for tubular secretion determination, TS) was designed and validated using a C-18 column, 0.1M acetic acid-10% acetonitrile (90:10, v/v) as mobile phase, at a flow rate of 0.3 ml/min, and UV detection at 270 nm. Iopamidol (244.8 mg/kg) was administered intravenously followed immediately by sodium PAH (100 mg/kg) to healthy female Sprague-Dawley rats. Plasma samples obtained at 2.5, 5, 10, 15, 20, 30, 45, 60, 90, and 120 min after drug administration were deproteinized with 2.5% trichloroacetic acid containing p-aminobenzoic acid as internal standard, and separated by the validated RP-HPLC method described above. The iopamidol and PAH chromatographic data were analyzed using a non-compartmental model. The results demonstrated that the RP-HPLC method was linear in ranges between 15-120 μg/ml and 2.5-120 μg/ml for iopamidol and PAH, respectively. Precision and accuracy were within 15% for both drugs. Recovery of iopamidol and PAH was 92% and 100%, respectively. Plasma iopamidol and PAH clearances in awake rats, estimates for GFR and TS, respectively, were 1.49±0.20 ml/min and 3.73±0.38 ml/min. In conclusion, the method here described is a simple and reliable procedure, for the simultaneous and time-saving determination of GFR and TS from plasma samples in the conscious rat. Copyright © 2014 Elsevier B.V. All rights reserved.

  10. Preparation of magnetic ODS-PAN thin-films for microextraction of quetiapine and clozapine in plasma and urine samples followed by HPLC-UV detection.

    PubMed

    Li, Dan; Zou, Juan; Cai, Pei-Shan; Xiong, Chao-Mei; Ruan, Jin-Lan

    2016-06-05

    In this study, conventional thin-film microextraction (TFME) was endowed with magnetic by introducing superparamagnetic SiO2@Fe3O4 nanoparticles in thin-films. Novel magnetic octadecylsilane (ODS)-polyacrylonitrile (PAN) thin-films were prepared by spraying, and used for the microextraction of quetiapine and clozapine in plasma and urine samples, followed by the detection of HPLC-UV. The influencing factors on the extraction efficiency of magnetic ODS-PAN TFME, including pH, extraction time, desorption solvent, desorption time, and ion strength were investigated systematically. Under the optimal conditions, both analytes showed good linearity over ranges of 0.070-9.000μgmL(-1) and 0.012-9.000μgmL(-1) in plasma and urine samples, respectively, with correlation coefficients (R(2)) above 0.9990. Limits of detection (LODs) for quetiapine in plasma and urine samples were 0.013 and 0.003μgmL(-1), respectively. LODs for clozapine in plasma and urine samples were 0.015 and 0.003μgmL(-1), respectively. The relative standard deviations (RSDs) for quetiapine and clozapine were less than 9.23%. After the validation, the protocol was successfully applied for the determination of quetiapine and clozapine in patients' plasma and urine samples with satisfactory recoveries between 99-110%. The proposed magnetic ODS-PAN TFME was very simple, fast and easy to handle. It showed high potential as a powerful pretreatment technology for routine therapeutic drug monitoring (TDM) in plasma and urine samples. Copyright © 2016 Elsevier B.V. All rights reserved.

  11. Concurrent determination of olanzapine, risperidone and 9-hydroxyrisperidone in human plasma by ultra performance liquid chromatography with diode array detection method: application to pharmacokinetic study.

    PubMed

    Siva Selva Kumar, M; Ramanathan, M

    2016-02-01

    A simple and sensitive ultra-performance liquid chromatography (UPLC) method has been developed and validated for simultaneous estimation of olanzapine (OLZ), risperidone (RIS) and 9-hydroxyrisperidone (9-OHRIS) in human plasma in vitro. The sample preparation was performed by simple liquid-liquid extraction technique. The analytes were chromatographed on a Waters Acquity H class UPLC system using isocratic mobile phase conditions at a flow rate of 0.3 mL/min and Acquity UPLC BEH shield RP18 column maintained at 40°C. Quantification was performed on a photodiode array detector set at 277 nm and clozapine was used as internal standard (IS). OLZ, RIS, 9-OHRIS and IS retention times were found to be 0.9, 1.4, .1.8 and 3.1 min, respectively, and the total run time was 4 min. The method was validated for selectivity, specificity, recovery, linearity, accuracy, precision and sample stability. The calibration curve was linear over the concentration range 1-100 ng/mL for OLZ, RIS and 9-OHRIS. Intra- and inter-day precisions for OLZ, RIS and 9-OHRIS were found to be good with the coefficient of variation <6.96%, and the accuracy ranging from 97.55 to 105.41%, in human plasma. The validated UPLC method was successfully applied to the pharmacokinetic study of RIS and 9-OHRIS in human plasma. Copyright © 2015 John Wiley & Sons, Ltd.

  12. Fast and parallel determination of PCB 77 and PCB 180 in plasma using ultra performance liquid chromatography with diode array detection: A pharmacokinetic study in Swiss albino mouse.

    PubMed

    Ramanujam, N; Sivaselvakumar, M; Ramalingam, S

    2017-11-01

    A simple, sensitive and reproducible ultra-performance liquid chromatography (UPLC) method has been developed and validated for simultaneous estimation of polychlorinated biphenyl (PCB) 77 and PCB 180 in mouse plasma. The sample preparation was performed by simple liquid-liquid extraction technique. The analytes were chromatographed on a Waters Acquity H class UPLC system using isocratic mobile phase conditions at a flow rate of 0.3 mL/min and Acquity UPLC BEH shield RP 18 column maintained at 35°C. Quantification was performed on a photodiode array detector set at 215 nm and PCB 101 was used as internal standard (IS). PCB 77, PCB 180, and IS retention times were 2.6, 4.7 and 2.8 min, respectively, and the total run time was 6 min. The method was validated for specificity, selectivity, recovery, linearity, accuracy, precision and sample stability. The calibration curve was linear over the concentration range 10-3000 ng/mL for PCB 77 and PCB 180. Intra- and inter-day precisions for PCBs 77 and 180 were found to be good with CV <4.64%, and the accuracy ranged from 98.90 to 102.33% in mouse plasma. The validated UPLC method was successfully applied to the pharmacokinetic study of PCBs 77 and 180 in mouse plasma. Copyright © 2017 John Wiley & Sons, Ltd.

  13. Peptidomic analysis of endogenous plasma peptides from patients with pancreatic neuroendocrine tumours.

    PubMed

    Kay, Richard G; Challis, Benjamin G; Casey, Ruth T; Roberts, Geoffrey P; Meek, Claire L; Reimann, Frank; Gribble, Fiona M

    2018-06-01

    Diagnosis of pancreatic neuroendocrine tumours requires the study of patient plasma with multiple immunoassays, using multiple aliquots of plasma. The application of mass spectrometry based techniques could reduce the cost and amount of plasma required for diagnosis. Plasma samples from two patients with pancreatic neuroendocrine tumours were extracted using an established acetonitrile based plasma peptide enrichment strategy. The circulating peptidome was characterised using nano and high flow rate LC/MS analyses. To assess the diagnostic potential of the analytical approach, a large sample batch (68 plasmas) from control subjects, and aliquots from subjects harbouring two different types of pancreatic neuroendocrine tumour (insulinoma and glucagonoma) were analysed using a 10-minute LC/MS peptide screen. The untargeted plasma peptidomics approach identified peptides derived from the glucagon prohormone, chromogranin A, chromogranin B and other peptide hormones and proteins related to control of peptide secretion. The glucagon prohormone derived peptides that were detected were compared against putative peptides that were identified using multiple antibody pairs against glucagon peptides. Comparison of the plasma samples for relative levels of selected peptides showed clear separation between the glucagonoma and the insulinoma and control samples. The combination of the organic solvent extraction methodology with high flow rate analysis could potentially be used to aid diagnosis and monitor treatment of patients with functioning pancreatic neuroendocrine tumours. However, significant validation will be required before this approach can be clinically applied. This article is protected by copyright. All rights reserved.

  14. Development and validation of a LC-MS/MS assay for quantitation of plasma citrulline for application to animal models of the acute radiation syndrome across multiple species.

    PubMed

    Jones, Jace W; Tudor, Gregory; Bennett, Alexander; Farese, Ann M; Moroni, Maria; Booth, Catherine; MacVittie, Thomas J; Kane, Maureen A

    2014-07-01

    The potential risk of a radiological catastrophe highlights the need for identifying and validating potential biomarkers that accurately predict radiation-induced organ damage. A key target organ that is acutely sensitive to the effects of irradiation is the gastrointestinal (GI) tract, referred to as the GI acute radiation syndrome (GI-ARS). Recently, citrulline has been identified as a potential circulating biomarker for radiation-induced GI damage. Prior to biologically validating citrulline as a biomarker for radiation-induced GI injury, there is the important task of developing and validating a quantitation assay for citrulline detection within the radiation animal models used for biomarker validation. Herein, we describe the analytical development and validation of citrulline detection using a liquid chromatography tandem mass spectrometry assay that incorporates stable-label isotope internal standards. Analytical validation for specificity, linearity, lower limit of quantitation, accuracy, intra- and interday precision, extraction recovery, matrix effects, and stability was performed under sample collection and storage conditions according to the Guidance for Industry, Bioanalytical Methods Validation issued by the US Food and Drug Administration. In addition, the method was biologically validated using plasma from well-characterized mouse, minipig, and nonhuman primate GI-ARS models. The results demonstrated that circulating citrulline can be confidently quantified from plasma. Additionally, circulating citrulline displayed a time-dependent response for radiological doses covering GI-ARS across multiple species.

  15. Rapid determination of tafenoquine in small volume human plasma samples by high-performance liquid chromatography-tandem mass spectrometry.

    PubMed

    Doyle, E; Fowles, S E; Summerfield, S; White, T J

    2002-03-25

    A method was developed for the determination of tafenoquine (I) in human plasma using high-performance liquid chromatography-tandem mass spectrometry. Prior to analysis, the protein in plasma samples was precipitated with methanol containing [2H3(15N)]tafenoquine (II) to act as an internal standard. The supernatant was injected onto a Genesis-C18 column without any further clean-up. The mass spectrometer was operated in the positive ion mode, employing a heat assisted nebulisation, electrospray interface. Ions were detected in multiple reaction monitoring mode. The assay required 50 microl of plasma and was precise and accurate within the range 2 to 500 ng/ml. The average within-run and between-run relative standard deviations were < 7% at 2 ng/ml and greater concentrations. The average accuracy of validation standards was generally within +/- 4% of the nominal concentration. There was no evidence of instability of I in human plasma following three complete freeze-thaw cycles and samples can safely be stored for at least 8 months at approximately -70 degrees C. The method was very robust and has been successfully applied to the analysis of clinical samples from patients and healthy volunteers dosed with I.

  16. Dried blood spot analysis for therapeutic drug monitoring of pazopanib.

    PubMed

    de Wit, Djoeke; den Hartigh, Jan; Gelderblom, Hans; Qian, Yanwen; den Hollander, Margret; Verheul, Henk; Guchelaar, Henk-Jan; van Erp, Nielka P

    2015-12-01

    Dried blood spot (DBS) sampling is potentially a more patient-friendly and flexible alternative to venous sampling of pazopanib. This study determined the agreement between pazopanib DBS and plasma concentrations to facilitate implementation of pazopanib DBS sampling into clinical practice. Paired DBS and plasma samples were collected in 12 patients. Pazopanib plasma concentrations were calculated from DBS concentrations using the formula: plasma concentration = DBSconcentration /(1 - hematocrit). Passing-Bablok and Bland-Altman analyses were used to determine the agreement between calculated and measured plasma concentrations. We predefined a clinical acceptance limit of 25% for the Bland-Altman analysis. Passing-Bablok analysis showed a small constant (intercept estimate, -8.53 [95%CI, -12.22 to -4.41]) and slightly proportional (slope estimate, 1.15 [95%CI, 1.04-1.24]) bias between calculated and measured concentrations. This bias was clinically nonrelevant, as shown by Bland-Altman analysis; the mean ratio of calculated to measured concentrations was 0.94 (95%CI, 0.65-1.23). The clinical acceptance limits were well within these 95% limits of agreement. More specifically, 92.6% of the data points were within the predefined acceptance limits. Pazopanib plasma concentrations can be accurately calculated from DBS concentrations. Although validation of DBS cards prepared by patients themselves is required, these results show that DBS sampling can be used to monitor pazopanib therapy in clinical practice. © 2015, The American College of Clinical Pharmacology.

  17. Development and validation of a sensitive LC-MS/MS method for the determination of fenoterol in human plasma and urine samples.

    PubMed

    Sanghvi, M; Ramamoorthy, A; Strait, J; Wainer, I W; Moaddel, R

    2013-08-15

    Due to the lack of sensitivity in current methods for the determination of fenoterol (Fen), a rapid LC-MS/MS method was developed for the determination of (R,R')-Fen and (R,R';S,S')-Fen in plasma and urine. The method was fully validated and was linear from 50pg/ml to 2000pg/ml for plasma and from 2.500ng/ml to 160ng/ml for urine with a lower limit of quantitation of 52.8pg/ml in plasma. The coefficient of variation was <15% for the high QC standards and <10% for the low QC standards in plasma and was <15% for the high and low QC standards in urine. The relative concentrations of (R,R')-Fen and (S,S')-Fen were determined using a chirobiotic T chiral stationary phase. The method was used to determine the concentration of (R,R')-Fen in plasma and urine samples obtained in an oral cross-over study of (R,R')-Fen and (R,R';S,S')-Fen formulations. The results demonstrated a potential pre-systemic enantioselective interaction in which the (S,S')-Fen reduces the sulfation of the active (R,R')-Fen. The data suggest that a non-racemic mixture of the Fen enantiomers may provide better bioavailability of the active (R,R')-Fen for use in the treatment of cardiovascular disease. Published by Elsevier B.V.

  18. A non-invasive assessment of skin carotenoid status through reflection spectroscopy is a feasible, reliable and potentially valid measure of fruit and vegetable consumption in a diverse community sample.

    PubMed

    Jilcott Pitts, Stephanie Bell; Jahns, Lisa; Wu, Qiang; Moran, Nancy E; Bell, Ronny A; Truesdale, Kimberly P; Laska, Melissa N

    2018-06-01

    To assess the feasibility, reliability and validity of reflection spectroscopy (RS) to assess skin carotenoids in a racially diverse sample. Study 1 was a cross-sectional study of corner store customers (n 479) who completed the National Cancer Institute Fruit and Vegetable Screener as well as RS measures. Feasibility was assessed by examining the time it took to complete three RS measures, reliability was assessed by examining the variation between three RS measures, and validity was examined by correlation with self-reported fruit and vegetable consumption. In Study 2, validity was assessed in a smaller sample (n 30) by examining associations between RS measures and dietary carotenoids, fruits and vegetables as calculated from a validated FFQ and plasma carotenoids. Eastern North Carolina, USA. It took on average 94·0 s to complete three RS readings per person. The average variation between three readings for each participant was 6·8 %. In Study 2, in models adjusted for age, race and sex, there were statistically significant associations between RS measures and (i) FFQ-estimated carotenoid intake (P<0·0001); (ii) FFQ-estimated fruit and vegetable consumption (P<0·010); and (iii) plasma carotenoids (P<0·0001). RS is a potentially improved method to approximate fruit and vegetable consumption among diverse participants. RS is portable and easy to use in field-based public health nutrition settings. More research is needed to investigate validity and sensitivity in diverse populations.

  19. Liquid chromatography/tandem mass spectrometry method for simultaneous determination of cocaine and its metabolite (-)ecgonine methyl ester in human acidified stabilized plasma samples.

    PubMed

    Liu, Yongzhen; Zheng, Bo; Strafford, Stephanie; Orugunty, Ravi; Sullivan, Michael; Gus, Jeffrey; Heidbreder, Christian; Fudala, Paul J; Nasser, Azmi

    2014-06-15

    Two simple, sensitive and rapid liquid chromatography/electrospray ionization tandem mass spectrometry (LC-ESI-MS/MS) methods (low range and high range) were developed and validated for the quantification of cocaine and its metabolite (-)ecgonine methyl ester (EME) in human acidified stabilized plasma samples. In the low range assay, cocaine and the internal standard, cocaine-D3, were extracted using a single step liquid-liquid extraction from human acidified stabilized plasma. For the high range assay, human acidified stabilized plasma containing cocaine, EME, and the internal standards, cocaine-D3 and EME-D3, was mixed with acetonitrile, and the protein precipitate was separated by centrifugation. Both cocaine and EME extracted from both assays were separated on a HILIC column and detected in positive ion mode using multiple reaction monitoring (MRM). Both methods were validated and the specificity, linearity, lower limit of quantitation (LLOQ), precision, accuracy, recoveries and stability were determined. The linear range for the low range assay was 0.01-5ng/mL for cocaine; in the high range assay values were 5-1000ng/mL for cocaine and 1-200ng/mL for EME. The correlation coefficient (R(2)) values for both assays were 0.993 or greater. The precision and accuracy for intra-day and inter-day were better than 13.0%. The recovery was above 85% and matrix effects were low with the matrix factor ranging from 0.817 to 1.10 for both analytes in both assays. The validated methods were successfully used to quantify the plasma concentrations of cocaine and EME in clinical pharmacokinetic and pharmacodynamic studies. Copyright © 2014 Elsevier B.V. All rights reserved.

  20. Capillary electrophoresis coupled with electrochemiluminescence for determination of atomoxetine hydrochloride and the study on its interactions with three proteins.

    PubMed

    Zeng, Hua-jin; Yang, Ran; Zhang, Ying; Li, Jian-jun; Qu, Ling-bo

    2015-03-01

    A simple, rapid and sensitive method for the determination of atomoxetine hydrochloride (AH) by capillary electrophoresis with electrochemiluminescence detection (CE-ECL) using tris(2,2'-bipyridyl) ruthenium (II) was developed. Under optimized conditions, the determinations of AH in capsules and rat plasmas and the study on its interactions with three plasma proteins, including bovine serum albumin, cytochrome c and myoglobin were performed successfully. Relative to some previous studies, in this paper the methodologies for the determination of AH in aqueous solution and spiked plasma systems were established, respectively. By comparing the difference between the two work curves of two systems, the matrix effect in plasma samples on the determination of AH by the CE-ECL method was discussed in detail. The results indicated that the effect of the matrix in plasma samples should not be ignored even if no obvious interference was found in the electropherograms and the establishment of method validation in complex samples by the CE-ECL method was necessary. Copyright © 2014 John Wiley & Sons, Ltd.

  1. Method validation and determinations of levofloxacin, metronidazole and sulfamethoxazole in an aqueous pharmaceutical, urine and blood plasma samples using quantitative nuclear magnetic resonance spectrometry.

    PubMed

    Salem, Alaa A; Mossa, Hussein A

    2012-01-15

    Selective, rapid and accurate quantitative proton nuclear magnetic resonance (qHNMR) method for the determination of levofloxacin, metronidazole benzoate and sulfamethoxazole in aqueous solutions was developed and validated. The method was successfully applied to the determinations of the drugs and their admixtures in pharmaceutical, urine and plasma samples. Maleic acid and sodium malate were used as internal standards. Effect of temperature on spectral measurements was evaluated. Linear dynamic ranges of 0.50-68.00, 0.13-11.30 and 0.24-21.00 mg per 0.60 mL solution were obtained for levofloxacin, metronidazole benzoate and sulfamethoxazole, respectively. Average recovery % in the range of 96.00-104.20 ± (0.17-2.91) was obtained for drugs in pure, pharmaceutical, plasma and urine samples. Inter and intra-day analyses gave average recoveries % in the ranges 96.10-98.40 ± (1.68-2.81) and 96.00-104.20 ± (0.17-2.91), respectively. Instrumental detection limits ≤0.03 mg per 0.6 mL were obtained for the three drugs. Developed method has demonstrated high performance characteristics for analyzing investigated drugs and their admixtures. Student t-test at 95% confidence level revealed insignificant bias between the real and measured contents of investigated drugs in pure, pharmaceutical, urine and plasma samples and its admixtures. Application of the statistical F-test revealed insignificant differences in precisions between the developed method and arbitrary selected reference methods. Copyright © 2011 Elsevier B.V. All rights reserved.

  2. ProteinSeq: High-Performance Proteomic Analyses by Proximity Ligation and Next Generation Sequencing

    PubMed Central

    Vänelid, Johan; Siegbahn, Agneta; Ericsson, Olle; Fredriksson, Simon; Bäcklin, Christofer; Gut, Marta; Heath, Simon; Gut, Ivo Glynne; Wallentin, Lars; Gustafsson, Mats G.; Kamali-Moghaddam, Masood; Landegren, Ulf

    2011-01-01

    Despite intense interest, methods that provide enhanced sensitivity and specificity in parallel measurements of candidate protein biomarkers in numerous samples have been lacking. We present herein a multiplex proximity ligation assay with readout via realtime PCR or DNA sequencing (ProteinSeq). We demonstrate improved sensitivity over conventional sandwich assays for simultaneous analysis of sets of 35 proteins in 5 µl of blood plasma. Importantly, we observe a minimal tendency to increased background with multiplexing, compared to a sandwich assay, suggesting that higher levels of multiplexing are possible. We used ProteinSeq to analyze proteins in plasma samples from cardiovascular disease (CVD) patient cohorts and matched controls. Three proteins, namely P-selectin, Cystatin-B and Kallikrein-6, were identified as putative diagnostic biomarkers for CVD. The latter two have not been previously reported in the literature and their potential roles must be validated in larger patient cohorts. We conclude that ProteinSeq is promising for screening large numbers of proteins and samples while the technology can provide a much-needed platform for validation of diagnostic markers in biobank samples and in clinical use. PMID:21980495

  3. Simultaneous determination of acetaminophen and dihydrocodeine in human plasma by UPLC-MS/MS: Its pharmacokinetic application.

    PubMed

    Qiu, Xiangjun; Lou, Dan; Su, Ding; Liu, Zebin; Gao, Pengtao; Zhang, Nan-sheng

    2015-06-15

    An ultra performance liquid chromatography tandem mass spectrometry (UPLC-MS/MS) method was developed and validated to determine acetaminophen (AAP) and dihydrocodeine (DHC) in human plasma simultaneously. Plasma samples were prepared using protein precipitation with acetonitrile, the two analytes and the internal standard midazolam were separated on an Acquity UPLC BEH C18 column and mass spectrometric analysis was performed using a QTrap5500 mass spectrometer coupled with an electro-spray ionization (ESI) source in the positive ion mode. The MRM transitions of m/z 151.2→110.0 and m/z 302.3→199.2 were used to quantify for AAP and DHC, respectively. The linearity of this method was found to be within the concentration range of 50-10000ng/mL for AAP, and 1-100ng/mL for DHC in human plasma, respectively. The lower limit of quantification (LLOQ) was 50ng/mL and 1ng/mL for AAP and DHC in human plasma, respectively. The relative standard deviations (RSD) of intra and inter precision were less than 10% for both AAP and DHC. The analysis time of per sample was 1.0min. The developed and validated method was successfully applied to a pharmacokinetic study of AAP (500mg) with DHC (20mg) capsule in Chinese healthy volunteers (N=20). Copyright © 2015 Elsevier B.V. All rights reserved.

  4. Ultra-performance liquid chromatography tandem mass spectrometry for simultaneous determination of natural steroid hormones in sea lamprey (Petromyzon marinus) plasma and tissues.

    PubMed

    Wang, Huiyong; Bussy, Ugo; Chung-Davidson, Yu-Wen; Li, Weiming

    2016-01-15

    This study aims to provide a rapid, sensitive and precise UPLC-MS/MS method for target steroid quantitation in biological matrices. We developed and validated an UPLC-MS/MS method to simultaneously determine 16 steroids in plasma and tissue samples. Ionization sources of Electrospray Ionization (ESI) and Atmospheric Pressure Chemical Ionization (APCI) were compared in this study by testing their spectrometry performances at the same chromatographic conditions, and the ESI source was found up to five times more sensitive than the APCI. Different sample preparation techniques were investigated for an optimal extraction of steroids from the biological matrices. The developed method exhibited excellent linearity for all analytes with regression coefficients higher than 0.99 in broad concentration ranges. The limit of detection (LOD) was from 0.003 to 0.1ng/mL. The method was validated according to FDA guidance and applied to determine steroids in sea lamprey plasma and tissues (fat and testes) by the developed method. Copyright © 2015. Published by Elsevier B.V.

  5. Spectrofluorimetric Method for Estimation of Curcumin in Rat Blood Plasma: Development and Validation

    NASA Astrophysics Data System (ADS)

    Trivedi, J.; Variya, B.; Gandhi, H.; Rathod, S. P.

    2016-01-01

    Curcumin is a medicinally important phytoconstituent of curcuminoids. The present study describes development of a simple method for estimation of curcumin in rat plasma. This method involves the use of spectrofluorimetry for evaluation of curcumin at 257 (Ex) and 504 nm (Em). Sample preparation involves only two steps: extraction of curcumin and drying the extract. Following this procedure, the samples are reconstituted with ethyl acetate, and relative fluorescence intensity is measured using a spectrofluorimeter. The method was validated as per CDER guidelines. The linearity of the method was found to be in the range of 100-500 ng/mL with accuracy and precision lying within 2% RSD. The LOD and LOQ were found to be 15.3 and 46.1 ng/mL, respectively. The method was applied for pharmacokinetic evaluation in rats, and AUC, Cmax, and Tmax were found to be 5580 ± 1006 h × ng/mL, 1526 ± 209 ng/mL, and 2.97 ± 0.28 h, respectively, with a plasma half-life of 1.14 ± 0.27 h.

  6. Quantitative determination of famotidine in human maternal plasma, umbilical cord plasma and urine using high-performance liquid chromatography - mass spectrometry

    PubMed Central

    Wang, Xiaoming; Rytting, Erik; Abdelrahman, Doaa R.; Nanovskaya, Tatiana N.; Hankins, Gary D.V.; Ahmed, Mahmoud S.

    2013-01-01

    The liquid chromatography with electrospray ionization mass spectrometry for the quantitative determination of famotidine in human urine, maternal and umbilical cord plasma was developed and validated. The plasma samples were alkalized with ammonium hydroxide and extracted twice with ethyl acetate. The extraction recovery of famotidine in maternal and umbilical cord plasma ranged from 53% to 64% and 72% to 79%, respectively. Urine samples were directly diluted with the initial mobile phase then injected into the HPLC system. Chromatographic separation of famotidine was achieved by using a Phenomenex Synergi™ Hydro-RP™ column with a gradient elution of acetonitrile and 10 mM ammonium acetate aqueous solution (pH 8.3, adjusted with ammonium hydroxide). Mass Spectrometric detection of famotidine was set in the positive mode and used a selected ion monitoring method. Carbon-13-labeled famotidine was used as internal standard. The calibration curves were linear (r2> 0.99) in the concentration ranges of 0.631-252 ng/mL for umbilical and maternal plasma samples, and of 0.075-30.0 μg/mL for urine samples. The relative deviation of method was less than 14% for intra- and inter-day assays, and the accuracy ranged between 93% and 110%. The matrix effect of famotidine in human urine, maternal and umbilical cord plasma is less than 17%. PMID:23401067

  7. A comparison of ARMS-Plus and droplet digital PCR for detecting EGFR activating mutations in plasma

    PubMed Central

    Zhang, Xinxin; Chang, Ning; Yang, Guohua; Zhang, Yong; Ye, Mingxiang; Cao, Jing; Xiong, Jie; Han, Zhiping; Wu, Shuo; Shang, Lei; Zhang, Jian

    2017-01-01

    In this study, we introduce a novel amplification refractory mutation system (ARMS)-based assay, namely ARMS-Plus, for the detection of epidermal growth factor receptor (EGFR) mutations in plasma samples. We evaluated the performance of ARMS-Plus in comparison with droplet digital PCR (ddPCR) and assessed the significance of plasma EGFR mutations in predicting efficacy of EGFR-tyrosine kinase inhibitor (TKI) regimen. A total of 122 advanced non-small cell lung cancer (NSCLC) patients were enrolled in this study. The tumor tissue samples from these patients were evaluated by conventional ARMS PCR method to confirm their EGFR mutation status. For the 116 plasma samples analyzed by ARMS-Plus, the sensitivity, specificity, and concordance rate were 77.27% (34/44), 97.22% (70/72), and 89.66% (104/116; κ=0.77, P<0.0001), respectively. Among the 71 plasma samples analyzed by both ARMS-Plus and ddPCR, ARMS-Plus showed a higher sensitivity than ddPCR (83.33% versus 70.83%). The presence of EGFR activating mutations in plasma was not associated with the response to EGFR-TKI, although further validation with a larger cohort is required to confirm the correlation. Collectively, the performance of ARMS-Plus and ddPCR are comparable. ARMS-Plus could be a potential alternative to tissue genotyping for the detection of plasma EGFR mutations in NSCLC patients. PMID:29340107

  8. Liquid chromatography tandem mass spectrometry method for the quantitative analysis of ceritinib in human plasma and its application to pharmacokinetic studies.

    PubMed

    Heudi, Olivier; Vogel, Denise; Lau, Yvonne Y; Picard, Franck; Kretz, Olivier

    2014-11-01

    Ceritinib is a highly selective inhibitor of an important cancer target, anaplastic lymphoma kinase (ALK). Because it is an investigational compound, there is a need to develop a robust and reliable analytical method for its quantitative determination in human plasma. Here, we report the validation of a liquid chromatography tandem mass spectrometry (LC-MS/MS) method for the rapid quantification of ceritinib in human plasma. The method consists of protein precipitation with acetonitrile, and salting-out assisted liquid-liquid extraction (SALLE) using a saturated solution of sodium chloride prior to analysis by LC-MS/MS with electrospray ionization (ESI) technique in positive mode. Samples were eluted at 0.800 mL min(-1) on Ascentis Express® C18 column (50 mm × 2.1 mm, 2.7 μm) with a mobile phase made of 0.1 % formic acid in water (A) and 0.1 % formic acid in acetonitrile (B). The method run time was 3.6 min and the low limit of quantification (LLOQ) was estimated at 1.00 ng mL(-1) when using 0.100 mL of human plasma. The assay was fully validated and the method exhibited sufficient specificity, accuracy, precision, and sensitivity. In addition, recovery data and matrix factor (MF) in normal and in hemolyzed plasmas were assessed, while incurred samples stability (ISS) for ceritinib was demonstrated for at least 21 months at a storage temperature of -65 °C or below. The method was successfully applied to the measurement of ceritinib in clinical samples and the data obtained on incurred samples reanalysis (ISR) showed that our method was reliable and suitable to support the analysis of samples from the clinical studies.

  9. Standardization and validation of a cytometric bead assay to assess antibodies to multiple Plasmodium falciparum recombinant antigens

    PubMed Central

    2012-01-01

    Background Multiplex cytometric bead assay (CBA) have a number of advantages over ELISA for antibody testing, but little information is available on standardization and validation of antibody CBA to multiple Plasmodium falciparum antigens. The present study was set to determine optimal parameters for multiplex testing of antibodies to P. falciparum antigens, and to compare results of multiplex CBA to ELISA. Methods Antibodies to ten recombinant P. falciparum antigens were measured by CBA and ELISA in samples from 30 individuals from a malaria endemic area of Kenya and compared to known positive and negative control plasma samples. Optimal antigen amounts, monoplex vs multiplex testing, plasma dilution, optimal buffer, number of beads required were assessed for CBA testing, and results from CBA vs. ELISA testing were compared. Results Optimal amounts for CBA antibody testing differed according to antigen. Results for monoplex CBA testing correlated strongly with multiplex testing for all antigens (r = 0.88-0.99, P values from <0.0001 - 0.004), and antibodies to variants of the same antigen were accurately distinguished within a multiplex reaction. Plasma dilutions of 1:100 or 1:200 were optimal for all antigens for CBA testing. Plasma diluted in a buffer containing 0.05% sodium azide, 0.5% polyvinylalcohol, and 0.8% polyvinylpyrrolidone had the lowest background activity. CBA median fluorescence intensity (MFI) values with 1,000 antigen-conjugated beads/well did not differ significantly from MFI with 5,000 beads/well. CBA and ELISA results correlated well for all antigens except apical membrane antigen-1 (AMA-1). CBA testing produced a greater range of values in samples from malaria endemic areas and less background reactivity for blank samples than ELISA. Conclusion With optimization, CBA may be the preferred method of testing for antibodies to P. falciparum antigens, as CBA can test for antibodies to multiple recombinant antigens from a single plasma sample and produces a greater range of values in positive samples and lower background readings for blank samples than ELISA. PMID:23259607

  10. A fabric phase sorptive extraction-High performance liquid chromatography-Photo diode array detection method for the determination of twelve azole antimicrobial drug residues in human plasma and urine.

    PubMed

    Locatelli, Marcello; Kabir, Abuzar; Innosa, Denise; Lopatriello, Teresa; Furton, Kenneth G

    2017-01-01

    This paper reports a novel fabric phase sorptive extraction-high performance liquid chromatography-photodiode array detection (FPSE-HPLC-PDA) method for the simultaneous extraction and analysis of twelve azole antimicrobial drug residues that include ketoconazole, terconazole, voriconazole, bifonazole, clotrimazole, tioconazole, econazole, butoconazole, miconazole, posaconazole, ravuconazole, and itraconazole in human plasma and urine samples. The selected azole antimicrobial drugs were well resolved by using a Luna C 18 column (250mm×4.6mm; 5μm particle size) in gradient elution mode within 36min. The analytical method was calibrated and validated in the range from 0.1 to 8μg/mL for all the drug compounds. Blank human plasma and urine were used as the sample matrix for the analysis; while benzyl-4-hydroxybenzoate was used as the internal standard (IS). The limit of quantification of the FPSE-HPLC-PDA method was found as 0.1μg/mL and the weighted-matrix matched standard calibration curves of the drugs showed a good linearity upto a concentration of 8μg/mL. The parallelism tests were also performed to evaluate whether overrange sample can be analyzed after dilution, without compromising the analytical performances of the validated method. The intra- and inter-day precision (RSD%) values were found ≤13.1% and ≤13.9%, respectively. The intra- and inter-day trueness (bias%) values were found in the range from -12.1% to 10.5%. The performances of the validated FPSE-HPLC-PDA were further tested on real samples collected from healthy volunteers after a single dose administration of itraconazole and miconazole. To the best of our knowledge, this is the first FPSE extraction procedure applied on plasma and urine samples for the simultaneous determination of twelve azole drugs possessing a wide range of logK ow values (extending from 0.4 for fluconazole to 6.70 of butoconazole) and could be adopted as a rapid and robust green analytical tool for clinical and pharmaceutical applications. Copyright © 2016 Elsevier B.V. All rights reserved.

  11. Clinical Validation of Therapeutic Drug Monitoring of Imipenem in Spent Effluent in Critically Ill Patients Receiving Continuous Renal Replacement Therapy: A Pilot Study

    PubMed Central

    Wen, Aiping; Li, Zhe; Yu, Junxian; Li, Ren; Cheng, Sheng; Duan, Meili; Bai, Jing

    2016-01-01

    Objectives The primary objective of this pilot study was to investigate whether the therapeutic drug monitoring of imipenem could be performed with spent effluent instead of blood sampling collected from critically ill patients under continuous renal replacement therapy. Methods A prospective open-label study was conducted in a real clinical setting. Both blood and effluent samples were collected pairwise before imipenem administration and 0.5, 1, 1.5, 2, 3, 4, 6, and 8 h after imipenem administration. Plasma and effluent imipenem concentrations were determined by reversed-phase high-performance liquid chromatography with ultraviolet detection. Pharmacokinetic and pharmacodynamic parameters of blood and effluent samples were calculated. Results Eighty-three paired plasma and effluent samples were obtained from 10 patients. The Pearson correlation coefficient of the imipenem concentrations in plasma and effluent was 0.950 (P<0.0001). The average plasma-to-effluent imipenem concentration ratio was 1.044 (95% confidence interval, 0.975 to 1.114) with Bland-Altman analysis. No statistically significant difference was found in the pharmacokinetic and pharmacodynamic parameters tested in paired plasma and effluent samples with Wilcoxon test. Conclusion Spent effluent of continuous renal replacement therapy could be used for therapeutic drug monitoring of imipenem instead of blood sampling in critically ill patients. PMID:27093294

  12. A plasma microRNA signature as a biomarker for acquired aplastic anemia.

    PubMed

    Hosokawa, Kohei; Kajigaya, Sachiko; Feng, Xingmin; Desierto, Marie J; Fernandez Ibanez, Maria Del Pilar; Rios, Olga; Weinstein, Barbara; Scheinberg, Phillip; Townsley, Danielle M; Young, Neal S

    2017-01-01

    Aplastic anemia is an acquired bone marrow failure characterized by marrow hypoplasia, a paucity of hematopoietic stem and progenitor cells, and pancytopenia of the peripheral blood, due to immune attack on the bone marrow. In aplastic anemia, a major challenge is to develop immune biomarkers to monitor the disease. We measured circulating microRNAs in plasma samples of aplastic anemia patients in order to identify disease-specific microRNAs. A total of 179 microRNAs were analyzed in 35 plasma samples from 13 aplastic anemia patients, 11 myelodysplastic syndrome patients, and 11 healthy controls using the Serum/Plasma Focus microRNA Polymerase Chain Reaction Panel. Subsequently, 19 microRNAs from the discovery set were investigated in the 108 plasma samples from 41 aplastic anemia patients, 24 myelodysplastic syndrome patients, and 43 healthy controls for validation, confirming that 3 microRNAs could be validated as dysregulated (>1.5-fold change) in aplastic anemia, compared to healthy controls. MiR-150-5p (induction of T-cell differentiation) and miR-146b-5p (involvement in the feedback regulation of innate immune response) were elevated in aplastic anemia plasma, whereas miR-1 was decreased in aplastic anemia. By receiver operating characteristic curve analysis, we developed a logistic model with these 3 microRNAs that enabled us to predict the probability of a diagnosis of aplastic anemia with an area under the curve of 0.86. Dysregulated expression levels of the microRNAs became normal after immunosuppressive therapy at 6 months. Specifically, miR-150-5p expression was significantly reduced after successful immunosuppressive therapy, but did not change in non-responders. We propose 3 novel plasma biomarkers in aplastic anemia, in which miR-150-5p, miR-146b-5p, and miR-1 can serve for diagnosis and miR-150-5p for disease monitoring. Clinicaltrials.gov identifiers:00260689, 00217594, 00961064. Copyright© Ferrata Storti Foundation.

  13. Analysis of malondialdehyde in human plasma samples through derivatization with 2,4-dinitrophenylhydrazine by ultrasound-assisted dispersive liquid-liquid microextraction-GC-FID approach.

    PubMed

    Malaei, Reyhane; Ramezani, Amir M; Absalan, Ghodratollah

    2018-05-04

    A sensitive and reliable ultrasound-assisted dispersive liquid-liquid microextraction (UA-DLLME) procedure was developed and validated for extraction and analysis of malondialdehyde (MDA) as an important lipids-peroxidation biomarker in human plasma. In this methodology, to achieve an applicable extraction procedure, the whole optimization processes were performed in human plasma. To convert MDA into readily extractable species, it was derivatized to hydrazone structure-base by 2,4-dinitrophenylhydrazine (DNPH) at 40 °C within 60 min. Influences of experimental variables on the extraction process including type and volume of extraction and disperser solvents, amount of derivatization agent, temperature, pH, ionic strength, sonication and centrifugation times were evaluated. Under the optimal experimental conditions, the enhancement factor and extraction recovery were 79.8 and 95.8%, respectively. The analytical signal linearly (R 2  = 0.9988) responded over a concentration range of 5.00-4000 ng mL -1 with a limit of detection of 0.75 ng mL -1 (S/N = 3) in the plasma sample. To validate the developed procedure, the recommend guidelines of Food and Drug Administration for bioanalytical analysis have been employed. Copyright © 2018. Published by Elsevier B.V.

  14. Analysis of ECs and related compounds in plasma: artifactual isomerization and ex vivo enzymatic generation of 2-MGs.

    PubMed

    Pastor, Antoni; Farré, Magí; Fitó, Montserrat; Fernandez-Aranda, Fernando; de la Torre, Rafael

    2014-05-01

    The analysis of peripheral endocannabinoids (ECs) is a good biomarker of the EC system. Their concentrations, from clinical studies, strongly depend on sample collection and time processing conditions taking place in clinical and laboratory settings. The analysis of 2-monoacylglycerols (MGs) (i.e., 2-arachidonoylglycerol or 2-oleoylglycerol) is a particularly challenging issue because of their ex vivo formation and chemical isomerization that occur after blood sample collection. We provide evidence that their ex vivo formation can be minimized by adding Orlistat, an enzymatic lipase inhibitor, to plasma. Taking into consideration the low cost of Orlistat, we recommend its addition to plasma collecting tubes while maintaining sample cold chain until storage. We have validated a method for the determination of the EC profile of a range of MGs and N-acylethanolamides in plasma that preserves the original isomer ratio of MGs. Nevertheless, the chemical isomerization of 2-MGs can only be avoided by an immediate processing and analysis of samples due to their instability during conservation. We believe that this new methodology can aid in the harmonization of the measurement of ECs and related compounds in clinical samples.

  15. Validation of the SHOX2/PTGER4 DNA Methylation Marker Panel for Plasma-Based Discrimination between Patients with Malignant and Nonmalignant Lung Disease.

    PubMed

    Weiss, Gunter; Schlegel, Anne; Kottwitz, Denise; König, Thomas; Tetzner, Reimo

    2017-01-01

    Low-dose computed tomography (LDCT) is used for screening for lung cancer (LC) in high-risk patients in the United States. The definition of high risk and the impact of frequent false-positive results of low-dose computed tomography remains a challenge. DNA methylation biomarkers are valuable noninvasive diagnostic tools for cancer detection. This study reports on the evaluation of methylation markers in plasma DNA for LC detection and discrimination of malignant from nonmalignant lung disease. Circulating DNA was extracted from 3.5-mL plasma samples, treated with bisulfite using a commercially available kit, purified, and assayed by real-time polymerase chain reaction for assessment of DNA methylation of short stature homeobox 2 gene (SHOX2), prostaglandin E receptor 4 gene (PTGER4), and forkhead box L2 gene (FOXL2). In three independent case-control studies these assays were evaluated and optimized. The resultant assay, a triplex polymerase chain reaction combining SHOX2, PTGER4, and the reference gene actin, beta gene (ACTB), was validated using plasma from patients with and without malignant disease. A panel of SHOX2 and PTGER4 provided promising results in three independent case-control studies examining a total of 330 plasma specimens (area under the receiver operating characteristic curve = 91%-98%). A validation study with 172 patient samples demonstrated significant discriminatory performance in distinguishing patients with LC from subjects without malignancy (area under the curve = 0.88). At a fixed specificity of 90%, sensitivity for LC was 67%; at a fixed sensitivity of 90%, specificity was 73%. Measurement of SHOX2 and PTGER4 methylation in plasma DNA allowed detection of LC and differentiation of nonmalignant diseases. Development of a diagnostic test based on this panel may provide clinical utility in combination with current imaging techniques to improve LC risk stratification. Copyright © 2016 International Association for the Study of Lung Cancer. Published by Elsevier Inc. All rights reserved.

  16. Method validation for simultaneous determination of chromium, molybdenum and selenium in infant formulas by ICP-OES and ICP-MS.

    PubMed

    Khan, Naeem; Jeong, In Seon; Hwang, In Min; Kim, Jae Sung; Choi, Sung Hwa; Nho, Eun Yeong; Choi, Ji Yeon; Kwak, Byung-Man; Ahn, Jang-Hyuk; Yoon, Taehyung; Kim, Kyong Su

    2013-12-15

    This study aimed to validate the analytical method for simultaneous determination of chromium (Cr), molybdenum (Mo), and selenium (Se) in infant formulas available in South Korea. Various digestion methods of dry-ashing, wet-digestion and microwave were evaluated for samples preparation and both inductively coupled plasma optical emission spectrometry (ICP-OES) and inductively coupled plasma mass spectrometry (ICP-MS) were compared for analysis. The analytical techniques were validated by detection limits, precision, accuracy and recovery experiments. Results showed that wet-digestion and microwave methods were giving satisfactory results for sample preparation, while ICP-MS was found more sensitive and effective technique than ICP-OES. The recovery (%) of Se, Mo and Cr by ICP-OES were 40.9, 109.4 and 0, compared to 99.1, 98.7 and 98.4, respectively by ICP-MS. The contents of Cr, Mo and Se in infant formulas by ICP-MS were found in good nutritional values in accordance to nutrient standards for infant formulas CODEX values. Copyright © 2013 Elsevier Ltd. All rights reserved.

  17. Analysis of iodinated X-ray contrast agents in water samples by ion chromatography and inductively-coupled plasma mass spectrometry.

    PubMed

    Sacher, Frank; Raue, Brigitte; Brauch, Heinz-Jürgen

    2005-08-26

    In this paper, an analytical method for the determination of six iodinated X-ray contrast agents (amidotrizoic acid, iohexol, iomeprol, iopamidol, iopromide, and ioxitalamic acid), iodide, and iodate in water samples is presented. The method is based on a separation of the analytes by ion chromatography (IC) and a subsequent detection by inductively-coupled plasma mass spectrometry (ICP-MS). The method was optimised with respect to separation conditions (column type and eluent composition) and extensively validated. Without pre-concentration of the samples, limits of detection below 0.2 microg/l could be achieved whereby reproducibility was below 6% for all compounds under investigation.

  18. Targeted Mass Spectrometric Approach for Biomarker Discovery and Validation with Nonglycosylated Tryptic Peptides from N-linked Glycoproteins in Human Plasma*

    PubMed Central

    Lee, Ju Yeon; Kim, Jin Young; Park, Gun Wook; Cheon, Mi Hee; Kwon, Kyung-Hoon; Ahn, Yeong Hee; Moon, Myeong Hee; Lee, Hyoung–Joo; Paik, Young Ki; Yoo, Jong Shin

    2011-01-01

    A simple mass spectrometric approach for the discovery and validation of biomarkers in human plasma was developed by targeting nonglycosylated tryptic peptides adjacent to glycosylation sites in an N-linked glycoprotein, one of the most important biomarkers for early detection, prognoses, and disease therapies. The discovery and validation of novel biomarkers requires complex sample pretreatment steps, such as depletion of highly abundant proteins, enrichment of desired proteins, or the development of new antibodies. The current study exploited the steric hindrance of glycan units in N-linked glycoproteins, which significantly affects the efficiency of proteolytic digestion if an enzymatically active amino acid is adjacent to the N-linked glycosylation site. Proteolytic digestion then results in quantitatively different peptide products in accordance with the degree of glycosylation. The effect of glycan steric hindrance on tryptic digestion was first demonstrated using alpha-1-acid glycoprotein (AGP) as a model compound versus deglycosylated alpha-1-acid glycoprotein. Second, nonglycosylated tryptic peptide biomarkers, which generally show much higher sensitivity in mass spectrometric analyses than their glycosylated counterparts, were quantified in human hepatocellular carcinoma plasma using a label-free method with no need for N-linked glycoprotein enrichment. Finally, the method was validated using a multiple reaction monitoring analysis, demonstrating that the newly discovered nonglycosylated tryptic peptide targets were present at different levels in normal and hepatocellular carcinoma plasmas. The area under the receiver operating characteristic curve generated through analyses of nonglycosylated tryptic peptide from vitronectin precursor protein was 0.978, the highest observed in a group of patients with hepatocellular carcinoma. This work provides a targeted means of discovering and validating nonglycosylated tryptic peptides as biomarkers in human plasma, without the need for complex enrichment processes or expensive antibody preparations. PMID:21940909

  19. Development and full validation of an UPLC-MS/MS method for the determination of an anti-allergic indolinone derivative in rat plasma, and application to a preliminary pharmacokinetic study.

    PubMed

    Oufir, Mouhssin; Sampath, Chethan; Butterweck, Veronika; Hamburger, Matthias

    2012-08-01

    The natural product (E,Z)-3-(4-hydroxy-3,5-dimethoxybenzylidene)indolin-2-one (indolinone) was identified some years ago as a nanomolar inhibitor of FcɛRI-receptor dependent mast cell degranulation. To further explore the potential of the compound, we established an UPLC-MS/MS assay for dosage in rat plasma. The method was fully validated according to FDA Guidance for industry. Results of this validation and long term stability study demonstrate that the method in lithium heparinized rat plasma is specific, accurate, precise and capable of producing reliable results according to recommendations of international guidelines. The method was validated with a LLOQ of 30.0 ng/mL and an ULOQ of 3000 ng/mL. The response versus concentration data were fitted with a first order polynomial with 1/X(2) weighting. No matrix effect was observed when using three independent sources of rat plasma. The average extraction recovery was consistent over the investigated range. This validation in rat plasma demonstrated that indolinone was stable for 190 days when stored below -65 °C; for 4 days at 10 °C in the autosampler; for 4h at RT, and during three successive freeze/thaw cycles at -65 °C. Preliminary pharmacokinetic data were obtained in male Sprague-Dawley rats (2 mg/kg BW i.v.). Blood samples taken from 0 to 12 h after injection were collected, and data analyzed with WinNonlin. A short half-life (4.30±0.14 min) and a relatively high clearance (3.83±1.46 L/h/kg) were found. Copyright © 2012 Elsevier B.V. All rights reserved.

  20. Quantitation of pregabalin in dried blood spots and dried plasma spots by validated LC-MS/MS methods.

    PubMed

    Kostić, Nađa; Dotsikas, Yannis; Jović, Nebojša; Stevanović, Galina; Malenović, Anđelija; Medenica, Mirjana

    2015-05-10

    In this paper, novel LC-MS/MS methods for the determination of antiepileptic drug pregabalin in dried matrix spots (DMS) are presented. This attractive technique of sample collection in micro amount was utilized in the form of dried blood spots (DBS) and dried plasma spots (DPS). Following a pre-column derivatization procedure, using n-propyl chloroformate in the presence of n-propanol, and consecutive liquid-liquid extraction, derivatized pregabalin and its internal standard, 4-aminocyclohexanecarboxylic acid, were detected in positive ion mode by applying two SRM transitions per analyte. A YMC-Pack Octyl column (50mm×4.0mm, 3μm particle size) maintained at 30°C, was utilized with running mobile phase composed of acetonitrile: 0.15% formic acid (85:15, v/v). Flow rate was 550μL/min and total run time 2min. Established methods were fully validated over the concentration range of 0.200-20.0μg/mL for DBS and 0.400-40.0μg/mL for DPS, respectively, while specificity, accuracy, precision, recovery, matrix-effect, stability, dilution integrity and spot homogeneity were found within acceptance criteria. Validated methods were applied for the determination of pregabalin levels in dried blood and plasma samples obtained from patients with epilepsy, after per os administration of commercial capsules. Comparison of drug level in blood and plasma, as well as correction steps undertaken in order to overcome hematocrit issue, when analyzing DBS, are also given. Copyright © 2015 Elsevier B.V. All rights reserved.

  1. Development and validation of an LC-MS/MS method for simultaneous quantification of levodopa and MD01 in rat plasma and its application to a pharmacokinetic study of mucuna pruriens extract.

    PubMed

    Yang, Guangjie; Zhang, Fangrong; Deng, Linfang; Chen, Chang; Cheng, Zhongzhe; Huang, Jiangeng; Liu, Jiangyun; Jiang, Hongliang

    2016-09-01

    Mucuna pruriens, an ancient Indian herbal medicine containing levodopa, is widely used for Parkinson's disease. In order to simultaneously determine levodopa and 1,1-dimethyl-3-carboxy-6,7-dihydroxy-1,2,3,4-tetrahydroisoquinoline (MD01) in rat plasma, an improved LC-MS/MS method was developed and validated for a pharmacokinetic study in rats orally administered levodopa or Mucuna pruriens extract (MPE). Elimination of matrix effect and improvement of extraction recovery were achieved through systematic optimization of reversed-phase and hydrophilic interaction chromatographic conditions together with sample clean-up procedures. A satisfactory chromatographic performance was obtained with a Thermo Aquasil C18 column (50 × 2.1 mm, 3 µm) using acetonitrile and water containing 0.2% formic acid as mobile phases. Futhermore, sodium metabisulfite and formic acid were used as stabilizers in neat solutions as well as rat plasma. The method was validated in a dynamic range of 20.0-10,000 ng/mL for levodopa and MD01; the intra- and inter-day precision and accuracy were acceptable. The method was successfully utilized to determine the levodopa level in plasma samples of rats administered levodopa or MPE. Pharmacokinetic results showed that an increase in the AUC of levodopa was observed in rats following oral administration of multiple doses of MPE. Copyright © 2016 John Wiley & Sons, Ltd. Copyright © 2016 John Wiley & Sons, Ltd.

  2. Development and validation of two liquid chromatography-tandem mass spectrometry methods for the determination of silibinin and silibinin hemisuccinate in human plasma.

    PubMed

    Sala, Federica; Albares, Pablo; Colovic, Milena; Persiani, Stefano; Rovati, Lucio C

    2014-01-15

    To investigate the pharmacokinetics of silibinin and silibinin hemisuccinate in human plasma, two high-performance liquid chromatography-tandem mass spectrometry (HPLC-MS/MS) methods were developed and validated. The methods require a small volume of sample (100μL), and the recovery of the analytes was complete with a good reproducibility (CV% 1.7-9.5), after a simple protein precipitation. Naringenin was used as internal standard. The chromatographic methods provided a good separation of diastereoisomers A and B of both silibinin and silibinin hemisuccinate onto a Chromolith Performance RP18e 100mm×3mm column, with a resolution of peaks from plasma matrix in less than 6min. The methods precision values expressed as CV% were always ≤6.2% and the accuracy was always well within the acceptable 15% range. Quantification was performed on a triple-quadrupole tandem mass spectrometer by Selected Reaction Monitoring (SRM) mode, in a negative ion mode, via electrospray ionization (ESI). The lower limit of quantitation was set at 5.0ng/mL (silibinin) and 25.0ng/mL (silibinin hemisuccinate), and the linearity was validated up to 1000.0 and 12,500.0ng/mL, for silibinin and silibinin hemisuccinate, respectively, with correlation coefficients (R(2)) of 0.991 or better. The methods were suitable for pharmacokinetic studies and were successfully applied to human plasma samples from subjects treated intravenously with Legalon(®) SIL at the dose of 20mg/kg, expressed as silibinin. Copyright © 2013 Elsevier B.V. All rights reserved.

  3. Analysis of nifedipine in human plasma and amniotic fluid by liquid chromatography-tandem mass spectrometry and its application to clinical pharmacokinetics in hypertensive pregnant women.

    PubMed

    Filgueira, Gabriela Campos de Oliveira; Filgueira, Osmany Alberto Silva; Carvalho, Daniela Miarelli; Marques, Maria Paula; Moisés, Elaine Christine Dantas; Duarte, Geraldo; Lanchote, Vera Lucia; Cavalli, Ricardo Carvalho

    2015-07-01

    Nifedipine is a dihydropyridine calcium channel blocker used for the treatment of hypertension in pregnant women. A liquid chromatography-tandem mass spectrometry (LC-MS/MS) method was developed and validated for analysis of nifedipine in human plasma and amniotic fluid. Separation of nifedipine and nitrendipine (IS) was performed using a LiChroCART(®) RP-Select B column and a mixture of water:acetonitrile:glacial acetic acid (30:70:0.5 v/v) as the mobile phase. Aliquots of 500μL of biological samples were extracted at pH 13 using dichloromethane:n-pentane (3:7 v/v). The validated method was applied to a study of the pharmacokinetics of nifedipine in human plasma and amniotic fluid samples collected up to 12h after administration of the last slow-release nifedipine (20mg/12h) dose to 12 hypertensive pregnant women. The estimated pharmacokinetic parameters of nifedipine showed a mean AUC(0-12) of 250.2ngh/mL, ClT/F of 89.2L/h, Vd/F of 600.0L and t1/2 5.1h. The mean amniotic fluid/plasma concentration ratio was 0.05. The methods proved to be highly sensitive by showing a lower quantification limit of 0.1ng/mL for both matrices. And this study reports for the first time the complete development and validation of the method to quantify nifedipine in amniotic fluid using LC-MS-MS. Copyright © 2015 Elsevier B.V. All rights reserved.

  4. Validation of a highly sensitive ICP-MS method for the determination of platinum in biofluids: application to clinical pharmacokinetic studies with oxaliplatin.

    PubMed

    Morrison, J G; White, P; McDougall, S; Firth, J W; Woolfrey, S G; Graham, M A; Greenslade, D

    2000-12-01

    ELOXATIN (Oxaliplatin) is a novel platinum containing anti-cancer agent with a diaminocyclohexane carrier ligand which has been approved in several major European countries. Clinical studies have demonstrated that the compound exhibits marked activity against colorectal cancers in combination with 5-fluorouracil (5-FU). The aim of this work was to develop and validate a highly sensitive inductively coupled plasma mass spectrometry assay for the determination of oxaliplatin-derived platinum in plasma ultrafiltrate, plasma and whole blood and to apply this technique to clinical pharmacokinetic studies with oxaliplatin. Ultratrace detection of platinum in plasma ultrafiltrate was achieved using ultrasonic nebulisation combined with ICP-MS. This technique allows detection of platinum at the 0.001 microg Pt/ml level in only 100 microl of matrix. Assays in blood and plasma utilised a standard Meinhardt nebuliser and spray chamber, achieving detection limits of 0.1 microg Pt/ml in 100 and 200 microl of matrix, respectively. The assays were validated (accuracy and precision within +/- 15%) over the concentration ranges: 0.001-0.250 microg Pt/ml in plasma ultrafiltrate and 0.1-10 microg Pt/ml for plasma and whole blood. The effect of sample digestion. dilution, long term frozen storage and quantitation in the presence of 5-FU were also investigated and validated. The method was used to monitor platinum exposure following oxaliplatin administration (130 mg/m2) to cancer patients. Following a 2 h i.v. infusion, peak platinum levels declined in a triphasic manner in all blood compartments. Free platinum was detected in plasma ultrafiltrate at low levels (0.001 0.010 microg Pt/ml) for up to 3 weeks. In conclusion, a highly sensitive and specific assay has been developed for the determination of platinum in biofluids. This method enabled characterisation of the long term exposure to platinum in patients following oxaliplatin treatment.

  5. Development and validation of a sensitive and fast UPLC-MS/MS method for simultaneous determination of seven bioactive compounds in rat plasma after oral administration of Guizhi-gancao decoction.

    PubMed

    Ji, Bin; Zhuo, Limeng; Yang, Bin; Wang, Yang; Li, Lin; Yu, Miao; Zhao, Yunli; Yu, Zhiguo

    2017-04-15

    Rapid, sensitive, selective and accurate UPLC-MS/MS method was developed and fully validated for simultaneous determination of cinnamaldehyde, cinnamic acid, 2-methoxy cinnamic acid, glycyrrhizic acid, glycyrrhetinic acid, liquiritigenin and isoliquiritin in rat plasma after oral administration of Guizhi-gancao decoction. Plasma samples were processed with a simple protein precipitation technique using acetonitrile, followed by chromatographic separation using a Thermo Hypersil GOLD C 18 column. A 11.0min linear gradient elution was used at a flow rate of 0.2mL/min with a mobile phase of 0.1% acetic acid containing 0.2mM ammonium acetate in water and acetonitrile. The analytes and internal standard, schisandrin, were detected using both positive and negative ion electrospray ionization in multiple reaction monitoring mode. The developed method was validated for intra-day and inter-day accuracy and precision whose values fell in the acceptable limits. Matrix effect was found to be minimal. Recovery efficiency of all the analytes was found to be >60%. Stability results showed that the analytes were stable at all the conditions. This validated method was successfully used to study the pharmacokinetics of multiple compounds in rat plasma after oral administration of Guizhi-gancao decoction. Copyright © 2017 Elsevier B.V. All rights reserved.

  6. Definitive Characterization of CA 19-9 in Resectable Pancreatic Cancer Using a Reference Set of Serum and Plasma Specimens.

    PubMed

    Haab, Brian B; Huang, Ying; Balasenthil, Seetharaman; Partyka, Katie; Tang, Huiyuan; Anderson, Michelle; Allen, Peter; Sasson, Aaron; Zeh, Herbert; Kaul, Karen; Kletter, Doron; Ge, Shaokui; Bern, Marshall; Kwon, Richard; Blasutig, Ivan; Srivastava, Sudhir; Frazier, Marsha L; Sen, Subrata; Hollingsworth, Michael A; Rinaudo, Jo Ann; Killary, Ann M; Brand, Randall E

    2015-01-01

    The validation of candidate biomarkers often is hampered by the lack of a reliable means of assessing and comparing performance. We present here a reference set of serum and plasma samples to facilitate the validation of biomarkers for resectable pancreatic cancer. The reference set includes a large cohort of stage I-II pancreatic cancer patients, recruited from 5 different institutions, and relevant control groups. We characterized the performance of the current best serological biomarker for pancreatic cancer, CA 19-9, using plasma samples from the reference set to provide a benchmark for future biomarker studies and to further our knowledge of CA 19-9 in early-stage pancreatic cancer and the control groups. CA 19-9 distinguished pancreatic cancers from the healthy and chronic pancreatitis groups with an average sensitivity and specificity of 70-74%, similar to previous studies using all stages of pancreatic cancer. Chronic pancreatitis patients did not show CA 19-9 elevations, but patients with benign biliary obstruction had elevations nearly as high as the cancer patients. We gained additional information about the biomarker by comparing two distinct assays. The two CA 9-9 assays agreed well in overall performance but diverged in measurements of individual samples, potentially due to subtle differences in antibody specificity as revealed by glycan array analysis. Thus, the reference set promises be a valuable resource for biomarker validation and comparison, and the CA 19-9 data presented here will be useful for benchmarking and for exploring relationships to CA 19-9.

  7. Definitive Characterization of CA 19-9 in Resectable Pancreatic Cancer Using a Reference Set of Serum and Plasma Specimens

    PubMed Central

    Haab, Brian B.; Huang, Ying; Balasenthil, Seetharaman; Partyka, Katie; Tang, Huiyuan; Anderson, Michelle; Allen, Peter; Sasson, Aaron; Zeh, Herbert; Kaul, Karen; Kletter, Doron; Ge, Shaokui; Bern, Marshall; Kwon, Richard; Blasutig, Ivan; Srivastava, Sudhir; Frazier, Marsha L.; Sen, Subrata; Hollingsworth, Michael A.; Rinaudo, Jo Ann; Killary, Ann M.; Brand, Randall E.

    2015-01-01

    The validation of candidate biomarkers often is hampered by the lack of a reliable means of assessing and comparing performance. We present here a reference set of serum and plasma samples to facilitate the validation of biomarkers for resectable pancreatic cancer. The reference set includes a large cohort of stage I-II pancreatic cancer patients, recruited from 5 different institutions, and relevant control groups. We characterized the performance of the current best serological biomarker for pancreatic cancer, CA 19–9, using plasma samples from the reference set to provide a benchmark for future biomarker studies and to further our knowledge of CA 19–9 in early-stage pancreatic cancer and the control groups. CA 19–9 distinguished pancreatic cancers from the healthy and chronic pancreatitis groups with an average sensitivity and specificity of 70–74%, similar to previous studies using all stages of pancreatic cancer. Chronic pancreatitis patients did not show CA 19–9 elevations, but patients with benign biliary obstruction had elevations nearly as high as the cancer patients. We gained additional information about the biomarker by comparing two distinct assays. The two CA 9–9 assays agreed well in overall performance but diverged in measurements of individual samples, potentially due to subtle differences in antibody specificity as revealed by glycan array analysis. Thus, the reference set promises be a valuable resource for biomarker validation and comparison, and the CA 19–9 data presented here will be useful for benchmarking and for exploring relationships to CA 19–9. PMID:26431551

  8. Development and validation of a fast micro-extraction by packed sorbent UHPLC-PDA method for the simultaneous determination of linezolid and ciprofloxacin in human plasma from patients with hospital-acquired pneumonia.

    PubMed

    Ferrone, Vincenzo; Carlucci, Maura; Cotellese, Roberto; Raimondi, Paolo; Cichella, Annadomenica; Marco, Lorenzo Di; Carlucci, Giuseppe

    2017-03-01

    An ultra high-performance liquid chromatographic (UHPLC) method with PDA detection was developed and validated for the simultaneous quantification of linezolid and ciprofloxacin in human plasma and applied in hospital acquired pneumonia patients (HAP). The method uses a semi-automated microextraction by packed sorbent for sample preparation. All parameters in the extraction step (pH, sample volume, sample dilution and number of aspiration - ejection cycles) and in the desorption step (percentage of acetonitrile in the solvent of elution and number of aspirations of elution solvent through the device) were statistically significant when the recovery was used as response. The method showed good linearity with correlation coefficients, r 2 >0.9995 for the two drugs, as well as high precision (RSD%<9.77% in each case), accuracy ranged from -6.2% to +8.2. The limit of quantification of the two drugs was established at 0.01 and 0.02μg/mL for ciprofloxacin and linezolid, respectively. Linezolid, ciprofloxacin and internal standard were extracted from human plasma with a mean recovery ranging from 92.4% to 97.4%. During validation, the concentrations of linezolid and ciprofloxacin were found to be stable after 3 freeze-thaw cycles and for at least 24h after extraction. This method will subsequently be used to quantify the drugs dosage in patients with HAP to establish if the dosage regimen given is sufficient to eradicate the infection at the target site. Copyright © 2016 Elsevier B.V. All rights reserved.

  9. Determination of albendazole sulfoxide in human plasma by using liquid chromatography-tandem mass spectrometry.

    PubMed

    Saraner, Nihal; Özkan, Güler Yağmur; Güney, Berrak; Alkan, Erkin; Burul-Bozkurt, Nihan; Sağlam, Onursal; Fikirdeşici, Ezgi; Yıldırım, Mevlüt

    2016-06-01

    A rapid, simple and sensitive method was developed and validated using liquid chromatography-tandem mass spectrometry (LC-MS/MS) for determination of albendazole sulfoxide (ABZOX) in human plasma. The plasma samples were extracted by protein precipitation using albendazole sulfoxide-d3 as internal standard (IS). The chromatographic separation was performed on Waters Xbridge C18Column (100×4.6mm, 3.5μm) with a mobile phase consisting of ammonia solution, water and methanol at a flow rate of 0.70mL/min. ABZOX was detected and identified by mass spectrometry with electrospray ionization (ESI) in positive ion and multiple-reaction monitoring (MRM) mode. The method was linear in the range of 3-1500ng/mL for ABZOX. This method was successfully applied to the bioequivalence study in human plasma samples. Copyright © 2016 Elsevier B.V. All rights reserved.

  10. Development and validation of a simple and sensitive method for quantification of levodopa and carbidopa in rat and monkey plasma using derivatization and UPLC-MS/MS.

    PubMed

    Junnotula, Venkatraman; Licea-Perez, Hermes

    2013-05-01

    A simple, selective, and sensitive quantitative method has been developed for the simultaneous determination of levodopa and carbidopa in rat and monkey plasma by protein precipitation using acetonitrile containing the derivatizing reagent, flourescamine. Derivatized products of levodopa and carbidopa were separated on a BEH C18 column (2.1 mm × 50 mm; 1.7 μm particle size) using ultra high performance liquid chromatography (UHPLC) without any further purification. Tandem mass spectrometry (MS/MS) was used for detection. The method was validated over the concentration range of 5-5000 ng/mL and 3-3000 ng/mL for levodopa and carbidopa, respectively in rat and monkey plasma. Due to the poor stability of the investigated analytes in biological matrices, a mixture of sodium metabisulfite and hydrazine dihydrochloride was used as a stabilizer. This method was successfully utilized to support pharmacokinetic studies in both species. The results from assay validations and incurred samples re-analysis show that the method is selective, sensitive and robust. To our knowledge, this is the first UHPLC-MS/MS based method that utilizes derivatization with fluorescamine and provides adequate sensitivity for both levodopa and carbidopa with 50 μL of sample and a run time of 3.5 min. Copyright © 2013 Elsevier B.V. All rights reserved.

  11. Effect of gemfibrozil on the pharmacokinetics of mitiglinide in rats.

    PubMed

    Jin, L; Cao, Q

    2012-01-01

    A sensitive and specific method was developed and validated for the determination of mitiglinide in plasma using LC-MS/MS. The effect of gemfibrozil on the pharmacokinetics of orally administered mitiglinide in rats was investigated. The validated method in positive electrospray ionization mode using MRM and fully validated according to commonly accepted criteria. The desired sensitivity of mitiglinide was achieved with an LOQ of 0.5 ng/mL and the short run time was suitable for analysis of the large batches of samples. The method was successfully used to analyze rats plasma samples for application in pharmacokinetic studies. Pharmacokinetic parameters of mitiglinide were determined in rats following oral (0.25, 0.5, 1 mg/kg) administration to rats in the presence and absence of gemfibrozil (1 mg/kg). Compared to those animals in an oral control group (given mitiglinide alone), the area under the plasma concentration-time curve (AUC) of mitiglinide were increased significantly by 2.8, 3.5, 4.1-fold (0.25, 0.5, 1 mg/kg) by gemfibrozil, respectively. Consequently, the bioavailability of mitiglinide in the presence of gemfibrozil was significantly enhanced compared to that in oral control group (only mitiglinide). Gemfibrozil significantly enhanced the oral bioavailability of mitiglinide, suggesting that concurrent use of gemfibrozil and mitiglinide should be monitored closely for potential drug interactions. © Georg Thieme Verlag KG Stuttgart · New York.

  12. Development of SPME-LC-MS method for screening of eight beta-blockers and bronchodilators in plasma and urine samples.

    PubMed

    Goryński, Krzysztof; Kiedrowicz, Alicja; Bojko, Barbara

    2016-08-05

    The current work describes the development and validation of a simple, efficient, and fast method using solid phase microextraction coupled to liquid chromatography-tandem mass spectrometry (SPME-LC-MS/MS) for the concomitant measurement of eight beta-blockers and bronchodilators in plasma and urine. The presented assay enables quantitative determination of acebutolol, atenolol, fenoterol, nadolol, pindolol, procaterol, sotalol, and timolol. In this work, samples were prepared on a high-throughput platform using the 96-well plate format of the thin film solid phase microextraction (TFME) system, and a biocompatible extraction phase made of hydrophilic-lipophilic balance particles. Analytes were separated on a pentafluorophenyl column (100mm×2.1mm, 3μm) by gradient elution using an UPLC Nexera coupled with an LCMS-8060 mass spectrometer. The mobile phase consisted of water-acetonitrile (0.1% formic acid) at a flow rate of 0.4mLmin(-1). The linearity of the method was checked within therapeutic blood-plasma concentrations, and shown to adequately reflect typically expected concentrations of future study samples. Post-extraction addition experiments showed that the matrix effect ranged in plasma from 98% for procaterol to 115% for nadolol, and in urine, from 85% for nadolol and pindolol to 119% for atenolol. The method was successfully validated using Food and Drug Administration (FDA) guidelines, and met all acceptance criteria for bioanalytical assays at five concentration levels for all selected drugs. The final protocol can be successfully applied for monitoring concentrations of the selected drugs in both plasma and urine matrices obtained from patients or athletes. Copyright © 2016 Elsevier B.V. All rights reserved.

  13. The local clinical validation of a new lithium heparin tube with a barrier: BD Vacutainer® Barricor LH Plasma tube.

    PubMed

    Arslan, Fatma Demet; Karakoyun, Inanc; Basok, Banu Isbilen; Aksit, Merve Zeytinli; Baysoy, Anil; Ozturk, Yasemin Kilic; Guclu, Yusuf Adnan; Duman, Can

    2017-10-15

    Although serum-providing blood tubes with a barrier are still widely used due to their significant advantages, the use of blood tubes with a barrier to provide plasma is becoming widespread. We compared 22 analytes in a BD Vacutainer® Barricor LH Plasma tube for local clinical validation of this new lithium heparin tube with a barrier. Samples from 44 volunteers were collected in different tubes (Becton Dickinson and Company): Z tube without additive (reference), clot-activator tube with gel (SST), lithium heparin tube without gel (LiH), and lithium heparin tube with barrier (Barricor). Analyte concentrations in different tubes were compared with the reference tube. All tubes were also evaluated according to additional testing (different centrifugation durations, blood-sampling techniques and individual differences). Aspartate aminotransferase (AST), glucose (Glc), potassium (K), lactate dehydrogenase (LD), sodium (Na), and total protein (TP) had a significant bias in Barricor (9.19%, - 3.24%, - 4.88%, 21.60%, - 0.40%, 5.03%, respectively) relative to the reference tube. There was no statistical difference between different centrifugation durations and individual differences for AST, K and LD in LiH and/or Barricor (P > 0.05). There was a significant bias for LD between LiH and Barricor in terms of blood-sampling techniques (21.2% and 12.4%, respectively). Recently, the use of plasma has become prominent due to some of its advantages. In this study, plasma AST, K, LD, Glc and TP levels in Barricor were clinically different in comparison to serum. The results of additional tests showed that higher levels of LD in Barricor did not result from haemolysis, and they might be related to other factors including number of platelets, cellular fragility, or functional environment.

  14. Multilaboratory Validation of First Action Method 2016.04 for Determination of Four Arsenic Species in Fruit Juice by High-Performance Liquid Chromatography-Inductively Coupled Plasma-Mass Spectrometry.

    PubMed

    Kubachka, Kevin; Heitkemper, Douglas T; Conklin, Sean

    2017-07-01

    Before being designated AOAC First Action Official MethodSM 2016.04, the U.S. Food and Drug Administration's method, EAM 4.10 High Performance Liquid Chromatography-Inductively Coupled Plasma-Mass Spectrometric Determination of Four Arsenic Species in Fruit Juice, underwent both a single-laboratory validation and a multilaboratory validation (MLV) study. Three federal and five state regulatory laboratories participated in the MLV study, which is the primary focus of this manuscript. The method was validated for inorganic arsenic (iAs) measured as the sum of the two iAs species arsenite [As(III)] and arsenate [As(V)], dimethylarsinic acid (DMA), and monomethylarsonic acid (MMA) by analyses of 13 juice samples, including three apple juice, three apple juice concentrate, four grape juice, and three pear juice samples. In addition, two water Standard Reference Materials (SRMs) were analyzed. The method LODs and LOQs obtained among the eight laboratories were approximately 0.3 and 2 ng/g, respectively, for each of the analytes and were adequate for the intended purpose of the method. Each laboratory analyzed method blanks, fortified method blanks, reference materials, triplicate portions of each juice sample, and duplicate fortified juice samples (one for each matrix type) at three fortification levels. In general, repeatability and reproducibility of the method was ≤15% RSD for each species present at a concentration >LOQ. The average recovery of fortified analytes for all laboratories ranged from 98 to 104% iAs, DMA, and MMA for all four juice sample matrixes. The average iAs results for SRMs 1640a and 1643e agreed within the range of 96-98% of certified values for total arsenic.

  15. Different exosome cargo from plasma/bronchoalveolar lavage in non-small-cell lung cancer.

    PubMed

    Rodríguez, Marta; Silva, Javier; López-Alfonso, Ana; López-Muñiz, María Belen; Peña, Cristina; Domínguez, Gemma; García, Jose Miguel; López-Gónzalez, Ana; Méndez, Miriam; Provencio, Mariano; García, Vanesa; Bonilla, Félix

    2014-09-01

    Tumor-derived exosomes mediate tumorigenesis by facilitating tumor growth, metastasis, development of drug resistance, and immunosuppression. However, little is known about the exosomes isolated from bronchoalveolar lavage (BAL) in patients with lung neoplasm. Exosomes isolated in plasma and BAL from 30 and 75 patients with tumor and nontumor pathology were quantified by acetylcholinesterase activity and characterized by Western Blot, Electron Microscopy, and Nanoparticle Tracking Analysis. Differences in exosome cargo were analyzed by miRNA quantitative PCR in pooled samples and validated in a second series of patients. More exosomes were detected in plasma than in BAL in both groups (P < 0.001). The most miRNAs evaluated by PCR array were detected in tumor plasma, tumor BAL, and nontumor BAL pools, but only 56% were detected in the nontumor plasma pool. Comparing the top miRNAs with the highest levels detected in each pool, we found close homology only between the BAL samples of the two pathologies. In tumor plasma, we found a higher percentage of miRNAs with increased levels than in tumor BAL or in nontumor plasma. The data reveal differences between BAL and plasma exosome amount and miRNA content. © 2014 Wiley Periodicals, Inc.

  16. A sensitive LC-MS/MS method for simultaneous determination of R-bambuterol and its active metabolite R-terbutaline in human plasma and urine with application to a clinical pharmacokinetic study.

    PubMed

    Zhou, Ting; Zhao, Ting; Cheng, Qing; Liu, Shan; Xu, Ling; Tan, Wen

    2014-07-01

    A sensitive liquid chromatography-tandem mass spectrometry (LC-MS/MS) method for simultaneous determination of R-bambuterol and its active metabolite R-terbutaline in human plasma and urine was established. The inhibition for the biotransformation of R-bambuterol in plasma was fully investigated. Plasma samples were prepared on ice and neostigmine metilsulfate added as a cholinesterase inhibitor immediately after sample collection. All samples were extracted with ethyl acetate and separated on a C₁₈ column under gradient elution with a mobile phase consisting of methanol and water containing 5 mm ammonium acetate at a flow rate of 0.6 mL/min. The analytes were detected by an API 4000 tandem mass spectrometer with positive electrospray ionization in multiple reaction monitoring mode. The established method was highly sensitive with the lower limit of quantification (LLOQ) of 10.00 pg/mL for each analyte in plasma. In urine samples, the LLOQs were 20.00 and 500.0 pg/mL for R-bambuterol and R-terbutaline, respectively. The intra- and inter-day precisions were <12.7 and <8.6% for plasma and urine, respectively. The analytical runtime within 6.0 min per sample made this method suitable for high-throughput determination. The validated method has been successfully applied to the human pharmacokinetic study of R-bambuterol involving 10 healthy volunteers. Copyright © 2013 John Wiley & Sons, Ltd.

  17. Validation of the Use of Dried Blood Spot (DBS) Method to Assess Vitamin A Status

    PubMed Central

    Fallah, Elham; Peighambardoust, Seyed Hadi

    2012-01-01

    Background: Vitamin A deficiency is an important dietary deficiency in the world. Thus, the ne¬cessity of screening for deficient populations is obvious. This paper introduces a fast, cheap and relatively reliable method called “dried blood spot” (DBS) method in screening the deficient populations. The validity of this method for retinol measurement was investigated. Method: The “precision” and “agreement” criteria of the DBS method were assessed. The preci¬sion was calculated and compared with those of plasma using F-test. The agreement was eva¬luated using Bland-Altman plot. Results: The imprecision of retinol measurements in dried spots was not significantly different from those of the control (plasma). A good correlation coefficient (r2=0.78) was obtained for dried spots’ retinol measurements versus plasma’s retinol analysis (P < 0.01). Paired t-test showed no significant difference between the DBS and retinol methods on a group level. Imprecision of DBS measurement was acceptable, compared to that of the plasma method. The difference be¬tween these two methods was not statistically significant on a group level. Conclusion: Application of DBS standard samples, in which a part of the plasma was replaced with the artificial plasma, was shown to be a reliable calibration mean for retinol measurements in DBS samples. Retinol in dried spots was stable for 90 days. Overall, the DBS method provided a precise measurement of retinol, showing results that were comparable with the measurement of retinol in plasma. PMID:24688932

  18. Could Digital PCR Be an Alternative as a Non-Invasive Prenatal Test for Trisomy 21: A Proof of Concept Study.

    PubMed

    El Khattabi, Laïla Allach; Rouillac-Le Sciellour, Christelle; Le Tessier, Dominique; Luscan, Armelle; Coustier, Audrey; Porcher, Raphael; Bhouri, Rakia; Nectoux, Juliette; Sérazin, Valérie; Quibel, Thibaut; Mandelbrot, Laurent; Tsatsaris, Vassilis; Vialard, François; Dupont, Jean-Michel

    2016-01-01

    NIPT for fetal aneuploidy by digital PCR has been hampered by the large number of PCR reactions needed to meet statistical requirements, preventing clinical application. Here, we designed an octoplex droplet digital PCR (ddPCR) assay which allows increasing the number of available targets and thus overcomes statistical obstacles. After technical optimization of the multiplex PCR on mixtures of trisomic and euploid DNA, we performed a validation study on samples of plasma DNA from 213 pregnant women. Molecular counting of circulating cell-free DNA was performed using a mix of hydrolysis probes targeting chromosome 21 and a reference chromosome. The results of our validation experiments showed that ddPCR detected trisomy 21 even when the sample's trisomic DNA content is as low as 5%. In a validation study of plasma samples from 213 pregnant women, ddPCR discriminated clearly between the trisomy 21 and the euploidy groups. Our results demonstrate that digital PCR can meet the requirements for non-invasive prenatal testing of trisomy 21. This approach is technically simple, relatively cheap, easy to implement in a diagnostic setting and compatible with ethical concerns regarding access to nucleotide sequence information. These advantages make it a potential technique of choice for population-wide screening for trisomy 21 in pregnant women.

  19. Detection of lung cancer using plasma protein profiling by matrix-assisted laser desorption/ionization mass spectrometry.

    PubMed

    Shevchenko, Valeriy E; Arnotskaya, Natalia E; Zaridze, David G

    2010-01-01

    There are no satisfactory plasma biomarkers which are available for the early detection and monitoring of lung cancer, one of the most frequent cancers worldwide. The aim of this study is to explore the application of matrix-assisted laser desorption/ionization time-of-flight mass spectrometry (MALDI-ToF MS) to plasma proteomic patterns to distinguish lung cancer patients from healthy individuals. The EDTA plasma samples have been pre-fractionated using magnetic bead kits functionalized with weak cation exchange coatings. We compiled MS protein profiles for 90 patients with squamous cell carcinomas (SCC) and compared them with profiles from 187 healthy controls. The MALDI-ToF spectra were analyzed statistically using ClinProTools bioinformatics software. Depending on the sample used, up to 441 peaks/spectrum could be detected in a mass range of 1000-20,000 Da; 33 of these proteins had statistically differential expression levels between SCC and control plasma (P < 0.001). The series of the peaks were automatically chosen as potential biomarker patterns in the training set. They allowed the discrimination of plasma samples from healthy control and samples from SCC patients (sensitivity and specificity >90%) in external validation test. These results suggest that plasma MALDI-ToF MS protein profiling can distinguish patients with SCC and also from healthy individuals with relatively high sensitivity and specificity and that MALDI- ToF MS is a potential tool for the screening of lung cancer.

  20. Comparison between dried blood spot and plasma sampling for therapeutic drug monitoring of antiepileptic drugs in children with epilepsy: A step towards home sampling.

    PubMed

    Linder, Camilla; Wide, Katarina; Walander, Malin; Beck, Olof; Gustafsson, Lars L; Pohanka, Anton

    2017-05-01

    To investigate if dried blood spots could be used for therapeutic drug monitoring of the antiepileptic drugs, carbamazepine, lamotrigine and valproic acid in children with epilepsy. Fingerprick blood samples from 46 children at a neuropediatric outpatient clinic was collected on filterpaper at the same time as capillary plasma sampling. A validated dried blood spot liquid chromatography tandem mass spectrometry method for carbamazepine, lamotrigine and valproic acid was compared with the routine plasma laboratory methods. Method agreement was evaluated and plasma concentrations were estimated by different conversion approaches. Strong correlation was shown between dried blood spot and plasma concentrations for all three drugs, with R2 values>0.89. Regression analysis showed a proportional bias with 35% lower dried blood spot concentrations for valproic acid (n=33) and concentrations were 18% higher for carbamazepine (n=17). A ratio approach was used to make a conversion from dried blood spots to estimated plasma for these two drugs. Dried blood spot concentrations were directly comparable with plasma for lamotrigine (n=20). This study supports that dried blood spot concentrations can be used as an alternative to plasma in a children population for three commonly used antiepileptic drugs with the possibility to expand by adding other antiepileptic drugs. Clinical decisions can be made based on converted (carbamazepine, valproic acid) or unconverted (lamotrigine) dried blood spot concentrations. Dried blood spot sampling, in the future taken at home, will simplify an effective therapeutic drug monitoring for this group of patients who often have concomitant disorders and also reduce costs for society. Copyright © 2016 The Canadian Society of Clinical Chemists. Published by Elsevier Inc. All rights reserved.

  1. Optimization and validation of sample preparation for metagenomic sequencing of viruses in clinical samples.

    PubMed

    Lewandowska, Dagmara W; Zagordi, Osvaldo; Geissberger, Fabienne-Desirée; Kufner, Verena; Schmutz, Stefan; Böni, Jürg; Metzner, Karin J; Trkola, Alexandra; Huber, Michael

    2017-08-08

    Sequence-specific PCR is the most common approach for virus identification in diagnostic laboratories. However, as specific PCR only detects pre-defined targets, novel virus strains or viruses not included in routine test panels will be missed. Recently, advances in high-throughput sequencing allow for virus-sequence-independent identification of entire virus populations in clinical samples, yet standardized protocols are needed to allow broad application in clinical diagnostics. Here, we describe a comprehensive sample preparation protocol for high-throughput metagenomic virus sequencing using random amplification of total nucleic acids from clinical samples. In order to optimize metagenomic sequencing for application in virus diagnostics, we tested different enrichment and amplification procedures on plasma samples spiked with RNA and DNA viruses. A protocol including filtration, nuclease digestion, and random amplification of RNA and DNA in separate reactions provided the best results, allowing reliable recovery of viral genomes and a good correlation of the relative number of sequencing reads with the virus input. We further validated our method by sequencing a multiplexed viral pathogen reagent containing a range of human viruses from different virus families. Our method proved successful in detecting the majority of the included viruses with high read numbers and compared well to other protocols in the field validated against the same reference reagent. Our sequencing protocol does work not only with plasma but also with other clinical samples such as urine and throat swabs. The workflow for virus metagenomic sequencing that we established proved successful in detecting a variety of viruses in different clinical samples. Our protocol supplements existing virus-specific detection strategies providing opportunities to identify atypical and novel viruses commonly not accounted for in routine diagnostic panels.

  2. Simultaneous and rapid determination of gefitinib, erlotinib and afatinib plasma levels using liquid chromatography/tandem mass spectrometry in patients with non-small-cell lung cancer.

    PubMed

    Hayashi, Hideki; Kita, Yutaro; Iihara, Hirotoshi; Yanase, Koumei; Ohno, Yasushi; Hirose, Chiemi; Yamada, Maya; Todoroki, Kenichiro; Kitaichi, Kiyoyuki; Minatoguchi, Shinya; Itoh, Yoshinori; Sugiyama, Tadashi

    2016-07-01

    A simultaneous, selective, sensitive and rapid liquid chromatography/tandem mass spectrometry method was developed and validated for the quantification of gefitinib, erlotinib and afatinib in 250 μL samples of human blood plasma. Diluted plasma samples were extracted using a liquid-phase extraction procedure with tert-butyl methyl ether. The three drugs were separated by high-performance liquid chromatography using a C18 column and an isocratic mobile phase running at a flow rate of 0.2 mL/min for 5 min. The drugs were detected using a tandem mass spectrometer with electrospray ionization using imatinib as an internal standard. Calibration curves were generated over the linear concentration range of 0.05-100 nm in plasma with a lower limit of quantification of 0.01 or 0.05 nm for all compounds. Finally, the validated method was applied to a clinical pharmacokinetic study in patients with nonsmall-cell lung cancer (NSCLC) following the oral administration of afatinib. These results indicate that this method is suitable for assessing the risks and benefits of chemotherapy in patients with NSCLC and is useful for therapeutic drug monitoring for NSCLC treatment. As far as we know, this is the first report on LC-MS/MS method for the simultaneous quantification of NSCLC tyrosine kinase inhibitor plasma concentrations including afatinib. Copyright © 2015 John Wiley & Sons, Ltd. Copyright © 2015 John Wiley & Sons, Ltd.

  3. Development and validation of a method using supported liquid extraction for the simultaneous determination of midazolam and 1'-hydroxy-midazolam in human plasma by liquid chromatography with tandem mass spectrometry detection.

    PubMed

    Svanström, Camilla; Hansson, Gunnar P; Svensson, Leif D; Sennbro, Carl Johan

    2012-01-25

    The metabolic conversion of midazolam (MDZ) to its main metabolite 1'-hydroxy-midazolam (1-OH-MDZ) can be used as a probe drug for cytochrome P450 3A (CYP3A) activity. A sensitive method for the simultaneous determination of MDZ and its metabolite 1-OH-MDZ in human plasma using supported liquid extraction (SLE) in combination with liquid chromatography-tandem mass spectrometry (LC-MS/MS) detection was developed and validated. Plasma samples (100 μL) were diluted with 0.5M NH(3) (aq) containing deuterated internal standards. The samples were extracted with ethyl acetate on a 96-well SLE-plate. Separation was performed on a Symmetry Shield RP18 column using an acidic gradient running from 2% to 95% methanol in 3 min. Detection was performed using a triple quadrupole mass spectrometer running in positive electrospray selected reaction monitoring (SRM) mode. The validated dynamic range was 0.2-100 nmol/L for both analytes. In the concentration range 0.6-75 nmol/L the extraction recoveries were in the ranges 91.2-98.6% and 94.5-98.3% for MDZ and 1-OH-MDZ, respectively. Matrix effects were more pronounced for MDZ than for 1-OH-MDZ but the response was still 75.4% or higher compared to a reference. The overall repeatability was within 2.2-7.6% for both analytes, the overall reproducibility was within 3.1-10.2% for both analytes and the overall accuracy bias was within -1.1 to 7.5% for both analytes. The method was successfully applied to determine the plasma concentrations of MDZ and 1-OH-MDZ in 14 healthy volunteers up to 24h after administration of a single oral dose of 2mg MDZ. The SLE technology was found to be convenient and suitable for sample preparation, and the developed method was found to be rapid, selective and reproducible for the simultaneous determination of MDZ and 1-OH-MDZ in human plasma. Copyright © 2011 Elsevier B.V. All rights reserved.

  4. LC-MS/MS quantification of next-generation biotherapeutics: a case study for an IgE binding Nanobody in cynomolgus monkey plasma.

    PubMed

    Sandra, Koen; Mortier, Kjell; Jorge, Lucie; Perez, Luis C; Sandra, Pat; Priem, Sofie; Poelmans, Sofie; Bouche, Marie-Paule

    2014-05-01

    Nanobodies(®) are therapeutic proteins derived from the smallest functional fragments of heavy chain-only antibodies. The development and validation of an LC-MS/MS-based method for the quantification of an IgE binding Nanobody in cynomolgus monkey plasma is presented. Nanobody quantification was performed making use of a proteotypic tryptic peptide chromatographically enriched prior to LC-MS/MS analysis. The validated LLOQ at 36 ng/ml was measured with an intra- and inter-assay precision and accuracy <20%. The required sensitivity could be obtained based on the selectivity of 2D LC combined with MS/MS. No analyte specific tools for affinity purification were used. Plasma samples originating from a PK/PD study were analyzed and compared with the results obtained with a traditional ligand-binding assay. Excellent correlations between the two techniques were obtained, and similar PK parameters were estimated. A 2D LC-MS/MS method was successfully developed and validated for the quantification of a next generation biotherapeutic.

  5. Development and Validation of Limited-Sampling Strategies for Predicting Amoxicillin Pharmacokinetic and Pharmacodynamic Parameters

    PubMed Central

    Suarez-Kurtz, Guilherme; Ribeiro, Frederico Mota; Vicente, Flávio L.; Struchiner, Claudio J.

    2001-01-01

    Amoxicillin plasma concentrations (n = 1,152) obtained from 48 healthy subjects in two bioequivalence studies were used to develop limited-sampling strategy (LSS) models for estimating the area under the concentration-time curve (AUC), the maximum concentration of drug in plasma (Cmax), and the time interval of concentration above MIC susceptibility breakpoints in plasma (T>MIC). Each subject received 500-mg amoxicillin, as reference and test capsules or suspensions, and plasma concentrations were measured by a validated microbiological assay. Linear regression analysis and a “jack-knife” procedure revealed that three-point LSS models accurately estimated (R2, 0.92; precision, <5.8%) the AUC from 0 h to infinity (AUC0-∞) of amoxicillin for the four formulations tested. Validation tests indicated that a three-point LSS model (1, 2, and 5 h) developed for the reference capsule formulation predicts the following accurately (R2, 0.94 to 0.99): (i) the individual AUC0-∞ for the test capsule formulation in the same subjects, (ii) the individual AUC0-∞ for both reference and test suspensions in 24 other subjects, and (iii) the average AUC0-∞ following single oral doses (250 to 1,000 mg) of various amoxicillin formulations in 11 previously published studies. A linear regression equation was derived, using the same sampling time points of the LSS model for the AUC0-∞, but using different coefficients and intercept, for estimating Cmax. Bioequivalence assessments based on LSS-derived AUC0-∞'s and Cmax's provided results similar to those obtained using the original values for these parameters. Finally, two-point LSS models (R2 = 0.86 to 0.95) were developed for T>MICs of 0.25 or 2.0 μg/ml, which are representative of microorganisms susceptible and resistant to amoxicillin. PMID:11600352

  6. NASA GRC and MSFC Space-Plasma Arc Testing Procedures

    NASA Technical Reports Server (NTRS)

    Ferguson, Dale C.; Vayner, Boris V.; Galofaro, Joel T.; Hillard, G. Barry; Vaughn, Jason; Schneider, Todd

    2007-01-01

    Tests of arcing and current collection in simulated space plasma conditions have been performed at the NASA Glenn Research Center (GRC) in Cleveland, Ohio, for over 30 years and at the Marshall Space Flight Center (MSFC) in Huntsville, Alabama, for almost as long. During this period, proper test conditions for accurate and meaningful space simulation have been worked out, comparisons with actual space performance in spaceflight tests and with real operational satellites have been made, and NASA has achieved our own internal standards for test protocols. It is the purpose of this paper to communicate the test conditions, test procedures, and types of analysis used at NASA GRC and MSFC to the space environmental testing community at large, to help with international space-plasma arcing-testing standardization. Discussed herein are neutral gas conditions, plasma densities and uniformity, vacuum chamber sizes, sample sizes and Debye lengths, biasing samples versus self-generated voltages, floating samples versus grounded samples, test electrical conditions, arc detection, preventing sustained discharges during testing, real samples versus idealized samples, validity of LEO tests for GEO samples, extracting arc threshold information from arc rate versus voltage tests, snapover, current collection, and glows at positive sample bias, Kapton pyrolysis, thresholds for trigger arcs, sustained arcs, dielectric breakdown and Paschen discharge, tether arcing and testing in very dense plasmas (i.e. thruster plumes), arc mitigation strategies, charging mitigation strategies, models, and analysis of test results. Finally, the necessity of testing will be emphasized, not to the exclusion of modeling, but as part of a complete strategy for determining when and if arcs will occur, and preventing them from occurring in space.

  7. Validation and long-term evaluation of a modified on-line chiral analytical method for therapeutic drug monitoring of (R,S)-methadone in clinical samples.

    PubMed

    Ansermot, Nicolas; Rudaz, Serge; Brawand-Amey, Marlyse; Fleury-Souverain, Sandrine; Veuthey, Jean-Luc; Eap, Chin B

    2009-08-01

    Matrix effects, which represent an important issue in liquid chromatography coupled to mass spectrometry or tandem mass spectrometry detection, should be closely assessed during method development. In the case of quantitative analysis, the use of stable isotope-labelled internal standard with physico-chemical properties and ionization behaviour similar to the analyte is recommended. In this paper, an example of the choice of a co-eluting deuterated internal standard to compensate for short-term and long-term matrix effect in the case of chiral (R,S)-methadone plasma quantification is reported. The method was fully validated over a concentration range of 5-800 ng/mL for each methadone enantiomer with satisfactory relative bias (-1.0 to 1.0%), repeatability (0.9-4.9%) and intermediate precision (1.4-12.0%). From the results obtained during validation, a control chart process during 52 series of routine analysis was established using both intermediate precision standard deviation and FDA acceptance criteria. The results of routine quality control samples were generally included in the +/-15% variability around the target value and mainly in the two standard deviation interval illustrating the long-term stability of the method. The intermediate precision variability estimated in method validation was found to be coherent with the routine use of the method. During this period, 257 trough concentration and 54 peak concentration plasma samples of patients undergoing (R,S)-methadone treatment were successfully analysed for routine therapeutic drug monitoring.

  8. Development and validation of a LC-MS method with electrospray ionization for the determination of the imidazole H3 antagonist ROS203 in rat plasma.

    PubMed

    Vacondio, Federica; Silva, Claudia; Fioni, Alessandro; Mor, Marco; Rivara, Mirko; Bordi, Fabrizio; Flammini, Lisa; Ballabeni, Vigilio; Barocelli, Elisabetta

    2008-01-07

    A rapid, simple and sensitive liquid chromatography-mass spectrometry (LC-MS) method was developed and validated for the determination of the imidazole H(3) antagonist ROS203 in rat plasma, using the superior homologue ROS287 as internal standard. Analyses were performed on an Agilent 1100 Series HPLC system employing a Supelco Ascentis C(18) column and isocratic elution with acetonitrile-10mM ammonium acetate buffer pH 4.0 (30:70, v/v) at a flow rate of 0.25 mL/min. An Applied Biosystems/MDS Sciex 150-EX single quadrupole mass spectrometer, equipped with an electrospray ionization interface was employed, operating in the positive ion mode. Plasma samples were deproteinized with acetonitrile (1:2), evaporated under nitrogen stream, reconstituted in the mobile phase and 5 microL were injected into the system. The retention times of ROS203 and IS were 2.20 and 2.90 min, respectively. Calibration curves in spiked plasma were linear over the concentration range of 2610-2.61 ng/mL with determination coefficients >0.99. The lower limit of quantification (LLOQ) was 2.61 ng/mL. The accuracy of the method was within 15%. Intra- and inter-day relative standard deviations were less or equal to 9.50% or 7.19%, respectively. The applicability of the LC-MS method was tested employing plasma samples obtained after i.p. administration of ROS203 to female Wistar rats to support a behavioral in vivo study. The specificity of the method was confirmed by the absence of interferences from endogenous substances. The reported method can provide the necessary sensitivity, linearity, precision, accuracy and specificity to allow the determination of ROS203 in rat plasma samples to support further pharmacokinetic assays.

  9. Large-Scale Interlaboratory Study to Develop, Analytically Validate and Apply Highly Multiplexed, Quantitative Peptide Assays to Measure Cancer-Relevant Proteins in Plasma*

    PubMed Central

    Abbatiello, Susan E.; Schilling, Birgit; Mani, D. R.; Zimmerman, Lisa J.; Hall, Steven C.; MacLean, Brendan; Albertolle, Matthew; Allen, Simon; Burgess, Michael; Cusack, Michael P.; Gosh, Mousumi; Hedrick, Victoria; Held, Jason M.; Inerowicz, H. Dorota; Jackson, Angela; Keshishian, Hasmik; Kinsinger, Christopher R.; Lyssand, John; Makowski, Lee; Mesri, Mehdi; Rodriguez, Henry; Rudnick, Paul; Sadowski, Pawel; Sedransk, Nell; Shaddox, Kent; Skates, Stephen J.; Kuhn, Eric; Smith, Derek; Whiteaker, Jeffery R.; Whitwell, Corbin; Zhang, Shucha; Borchers, Christoph H.; Fisher, Susan J.; Gibson, Bradford W.; Liebler, Daniel C.; MacCoss, Michael J.; Neubert, Thomas A.; Paulovich, Amanda G.; Regnier, Fred E.; Tempst, Paul; Carr, Steven A.

    2015-01-01

    There is an increasing need in biology and clinical medicine to robustly and reliably measure tens to hundreds of peptides and proteins in clinical and biological samples with high sensitivity, specificity, reproducibility, and repeatability. Previously, we demonstrated that LC-MRM-MS with isotope dilution has suitable performance for quantitative measurements of small numbers of relatively abundant proteins in human plasma and that the resulting assays can be transferred across laboratories while maintaining high reproducibility and quantitative precision. Here, we significantly extend that earlier work, demonstrating that 11 laboratories using 14 LC-MS systems can develop, determine analytical figures of merit, and apply highly multiplexed MRM-MS assays targeting 125 peptides derived from 27 cancer-relevant proteins and seven control proteins to precisely and reproducibly measure the analytes in human plasma. To ensure consistent generation of high quality data, we incorporated a system suitability protocol (SSP) into our experimental design. The SSP enabled real-time monitoring of LC-MRM-MS performance during assay development and implementation, facilitating early detection and correction of chromatographic and instrumental problems. Low to subnanogram/ml sensitivity for proteins in plasma was achieved by one-step immunoaffinity depletion of 14 abundant plasma proteins prior to analysis. Median intra- and interlaboratory reproducibility was <20%, sufficient for most biological studies and candidate protein biomarker verification. Digestion recovery of peptides was assessed and quantitative accuracy improved using heavy-isotope-labeled versions of the proteins as internal standards. Using the highly multiplexed assay, participating laboratories were able to precisely and reproducibly determine the levels of a series of analytes in blinded samples used to simulate an interlaboratory clinical study of patient samples. Our study further establishes that LC-MRM-MS using stable isotope dilution, with appropriate attention to analytical validation and appropriate quality control measures, enables sensitive, specific, reproducible, and quantitative measurements of proteins and peptides in complex biological matrices such as plasma. PMID:25693799

  10. A Simple and High-Throughput Analysis of Amatoxins and Phallotoxins in Human Plasma, Serum and Urine Using UPLC-MS/MS Combined with PRiME HLB μElution Platform

    PubMed Central

    Zhang, Shuo; Zhao, Yunfeng; Li, Haijiao; Zhou, Shuang; Chen, Dawei; Zhang, Yizhe; Yao, Qunmei; Sun, Chengye

    2016-01-01

    Amatoxins and phallotoxins are toxic cyclopeptides found in the genus Amanita and are among the predominant causes of fatal food poisoning in China. In the treatment of Amanita mushroom poisoning, an early and definite diagnosis is necessary for a successful outcome, which has prompted the development of protocols for the fast and confirmatory determination of amatoxins and phallotoxins in human biological fluids. For this purpose, a simple, rapid and sensitive multiresidue UPLC-MS/MS method for the simultaneous determination of α-amanitin, β-amanitin, γ-amanitin, phalloidin (PHD) and phallacidin (PCD) in human plasma, serum and urine was developed and validated. The diluted plasma, serum and urine samples were directly purified with a novel PRiME technique on a 96-well μElution plate platform, which allowed high-throughput sample processing and low reagent consumption. After purification, a UPLC-MS/MS analysis was performed using positive electrospray ionization (ESI+) in multiple reaction monitoring (MRM) mode. This method fulfilled the requirements of a validation test, with good results for the limit of detection (LOD), lower limit of quantification (LLOQ), accuracy, intra- and inter-assay precision, recovery and matrix effects. All of the analytes were confirmed and quantified in authentic plasma, serum and urine samples obtained from cases of poisoning using this method. Using the PRiME μElution technique for quantification reduces labor and time costs and represents a suitable method for routine toxicological and clinical emergency analysis. PMID:27153089

  11. Capillary electrophoresis tandem mass spectrometry determination of glutamic acid and homocysteine's metabolites: Potential biomarkers of amyotrophic lateral sclerosis.

    PubMed

    Cieslarova, Zuzana; Lopes, Fernando Silva; do Lago, Claudimir Lucio; França, Marcondes Cavalcante; Colnaghi Simionato, Ana Valéria

    2017-08-01

    Amyotrophic lateral sclerosis (ALS) is a neurodegenerative disease that affects both lower and upper motor neurons, leading to muscle atrophy, paralysis, and death caused by respiratory failure or infectious complications. Altered levels of homocysteine, cysteine, methionine, and glutamic acid have been observed in plasma of ALS patients. In this context, a method for determination of these potential biomarkers in plasma by capillary electrophoresis tandem mass spectrometry (CE-MS/MS) is proposed herein. Sample preparation was carefully investigated, since sulfur-containing amino acids may interact with plasma proteins. Owing to the non-thiol sulfur atom in methionine, it was necessary to split sample preparation into two methods: i) determination of homocysteine and cysteine as S-acetyl amino acids; ii) determination of glutamic acid and methionine. All amino acids were separated within 25min by CE-MS/MS using 5molL -1 acetic acid as background electrolyte and 5mmolL -1 acetic acid in 50% methanol/H 2 O (v/v) as sheath liquid. The proposed CE-MS/MS method was validated, presenting RSD values below 6% and 11% for intra- and inter-day precision, respectively, for the middle concentration level within the linear range. The limits of detection ranged from 35 (homocysteine) to 268nmolL -1 (glutamic acid). The validated method was applied to the analysis of plasma samples from a group of healthy individuals and patients with ALS, showing the potential of glutamic acid and homocysteine metabolites as biomarkers of ALS. Copyright © 2017 Elsevier B.V. All rights reserved.

  12. Quantitative determination of total cesium in highly active liquid waste by using liquid electrode plasma optical emission spectrometry.

    PubMed

    Do, Van-Khoai; Yamamoto, Masahiko; Taguchi, Shigeo; Takamura, Yuzuru; Surugaya, Naoki; Kuno, Takehiko

    2018-06-01

    A sensitive analytical method for determination of total cesium (Cs) in highly active liquid waste (HALW) by using modified liquid electrode plasma optical emission spectrometry (LEP-OES) is developed in this study. The instrument is modified to measure radioactive samples in a glove box. The effects of important factors, including pulsed voltage sequence and nitric acid concentration, on the emission of Cs are investigated. The limit of detection (LOD) and limit of quantification (LOQ) are 0.005 mg/L and 0.02 mg/L, respectively. The achieved LOD is one order lower than that of recently developed spectroscopic methods using liquid discharge plasma. The developed method is validated by subjecting a simulated HALW sample to inductively coupled plasma mass spectrometry (ICP-MS). The recoveries obtained from a spike-and-recovery test are 96-102%, implying good accuracy. The method is successfully applied to the quantification of Cs in a real HALW sample at the Tokai reprocessing plant in Japan. Apart from dilution and filtration of the HALW sample, no other pre-treatment process is required. The results agree well with the values obtained using gamma spectrometry. The developed method offers a reliable technique for rapid analysis of total Cs in HALW samples. Copyright © 2018 Elsevier B.V. All rights reserved.

  13. Low gas flow inductively coupled plasma optical emission spectrometry for the analysis of food samples after microwave digestion.

    PubMed

    Nowak, Sascha; Gesell, Monika; Holtkamp, Michael; Scheffer, Andy; Sperling, Michael; Karst, Uwe; Buscher, Wolfgang

    2014-11-01

    In this work, the recently introduced low flow inductively coupled plasma optical emission spectrometry (ICP-OES) with a total argon consumption below 0.7 L/min is applied for the first time to the field of food analysis. One goal is the investigation of the performance of this low flow plasma compared to a conventional ICP-OES system when non-aqueous samples with a certain matrix are introduced into the system. For this purpose, arsenic is determined in three different kinds of fish samples. In addition several nutrients (K, Na, Mg, Ca) and trace metals (Co, Cu, Mn, Cd, Pb, Zn, Fe, and Ni) are determined in honey samples (acacia) after microwave digestion. The precision of the measurements is characterized by relative standard deviations (RSD) and compared to the corresponding precision values achieved using the conventional Fassel-type torch of the ICP. To prove the accuracy of the low flow ICP-OES method, the obtained data from honey samples are validated by a conventional ICP-OES. For the measurements concerning arsenic in fish, the low flow ICP-OES values are validated by conventional Fassel-type ICP-OES. Furthermore, a certified reference material was investigated with the low gas flow setup. Limits of detection (LOD), according to the 3σ criterion, were determined to be in the low microgram per liter range for all analytes. Recovery rates in the range of 96-106% were observed for the determined trace metal elements. It was proven that the low gas flow ICP-OES leads to results that are comparable with those obtained with the Fassel-type torch for the analysis of food samples. Copyright © 2014 Elsevier B.V. All rights reserved.

  14. Simple and rapid determination of norethindrone in human plasma by supported liquid extraction and ultra performance liquid chromatography with tandem mass spectrometry.

    PubMed

    Gong, Zhilong; Chandler, Kiresha; Webster, Stephen; Kerley, Remy; Buist, Susan; McCort-Tipton, Melanie

    2012-03-15

    We report for the first time an ultra performance liquid chromatographic method with tandem mass spectrometric detection (UPLC/MS/MS) for the determination of norethindrone alone in human plasma over the concentration range of 50.0-25000 pg mL(-1) using a sample volume of 0.250 mL. Norethindrone and its internal standard (ISTD), norethindrone-(13)C(2), were extracted from human plasma by supported liquid extraction (SLE). After evaporation of the organic solvent, samples were reconstituted and analyzed on an UPLC/MS/MS system. The UPLC system used a Waters BEH C18 (100 mm × 2.1mm, 1.7 μm) column with mobile phase A of 0.05% formic acid in water:acetonitrile (65:35, v/v) and mobile phase B of 0.05% formic acid in methanol:acetonitrile (50:50, v/v). The flow rate was 0.500 mL min(-1). The method was fully validated. The inter-run accuracy and precision at the lower limit of quantitation (LLOQ), low, mid and high quality control (QC) concentration levels were 99.2-108.4% with a <8.1% CV (coefficient of variation), respectively. The validated method has been successfully applied to analysis of thousands of pharmacokinetic samples. Copyright © 2012 Elsevier B.V. All rights reserved.

  15. Blood Sampling and Preparation Procedures for Proteomic Biomarker Studies of Psychiatric Disorders.

    PubMed

    Guest, Paul C; Rahmoune, Hassan

    2017-01-01

    A major challenge in proteomic biomarker discovery and validation for psychiatric diseases is the inherent biological complexity underlying these conditions. There are also many technical issues which hinder this process such as the lack of standardization in sampling, processing and storage of bio-samples in preclinical and clinical settings. This chapter describes a reproducible procedure for sampling blood serum and plasma that is specifically designed for maximizing data quality output in two-dimensional gel electrophoresis, multiplex immunoassay and mass spectrometry profiling studies.

  16. External validation of the bilirubin-atazanavir nomogram for assessment of atazanavir plasma exposure in HIV-1-infected patients.

    PubMed

    Rekić, Dinko; Röshammar, Daniel; Bergstrand, Martin; Tarning, Joel; Calcagno, Andrea; D'Avolio, Antonio; Ormaasen, Vidar; Vigan, Marie; Barrail-Tran, Aurélie; Ashton, Michael; Gisslén, Magnus; Äbelö, Angela

    2013-04-01

    Atazanavir increases plasma bilirubin levels in a concentration-dependent manner. Due to less costly and readily available assays, bilirubin has been proposed as a marker of atazanavir exposure. In this work, a previously developed nomogram for detection of suboptimal atazanavir exposure is validated against external patient populations. The bilirubin nomogram was validated against 311 matching bilirubin and atazanavir samples from 166 HIV-1-infected Norwegian, French, and Italian patients on a ritonavir-boosted regimen. In addition, the nomogram was evaluated in 56 Italian patients on an unboosted regimen. The predictive properties of the nomogram were validated against observed atazanavir plasma concentrations. The use of the nomogram to detect non-adherence was also investigated by simulation. The bilirubin nomogram predicted suboptimal exposure in the patient populations on a ritonavir-boosted regimen with a negative predictive value of 97% (95% CI 95-100). The bilirubin nomogram and monitoring of atazanavir concentrations had similar predictive properties for detecting non-adherence based on simulations. Although both methods performed adequately during a period of non-adherence, they had lower predictive power to detect past non-adherence episodes. Using the bilirubin nomogram for detection of suboptimal atazanavir exposure in patients on a ritonavir-boosted regimen is a rapid and cost-effective alternative to routine measurements of the actual atazanavir exposure in plasma. Its application may be useful in clinical settings if atazanavir concentrations are not available.

  17. HPLC-MS method for the quantification of nine anti-HIV drugs from dry plasma spot on glass filter and their long term stability in different conditions.

    PubMed

    D'Avolio, Antonio; Simiele, Marco; Siccardi, Marco; Baietto, Lorena; Sciandra, Mauro; Bonora, Stefano; Di Perri, Giovanni

    2010-09-05

    A bioanalytical method for the determination of most commonly prescribed protease inhibitors (saquinavir, atazanavir, amprenavir, darunavir, lopinavir and ritonavir) and non-nucleoside reverse transcriptase inhibitors (etravirine, efavirenz and nevirapine) was developed, modifying our previous HPLC-MS chromatographic run, validated and a complete short and long term stability evaluation was carried out. One hundred microlitres of plasma were distributed on a collection glass paper filter (Glass-Microfibre from Sartorius), then the filter underwent thermal treatment, both for drying and for HIV inactivation, and stored at room temperature, 4 degrees C and -20 degrees C. The analytes were extracted from the filter disc using tert-butylmethylether with basic pH, after the addition of the internal standards quinoxaline. The extract was dried, reconstituted and the chromatographic separation was performed on a reversed-phase C-18 column (150 mm x 2.0 mm) and the analytes were quantified using a single quadrupole mass spectrometer. The method was validated considering the concentration ranges encountered in clinical trials and the routine clinical practice. The assay was linear over the concentration ranges tested. Accuracies ranged from 92.1% to 111.9% and intra-day and inter-day relative standard deviation for all quality control levels ranged from 0.2 to 12.9 and 3.1 to 14.4, respectively. Analytes in dried plasma spots were stable for longer time when dried/inactivation step was carried out before storage compared to samples not dried/inactivated before the analysis. The dried/inactivation step allows shipment of samples at room temperature without any risks, therefore the developed and validated method enables an easy and cheap sample shipment for therapeutic drug monitoring and pharmacokinetic studies. 2010 Elsevier B.V. All rights reserved.

  18. Acamprosate determinations in plasma and cerebrospinal fluid after multiple dosing measured by liquid chromatography-mass spectroscopy: a pharmacokinetic study in healthy volunteers.

    PubMed

    Hammarberg, Anders; Beck, Olof; Eksborg, Staffan; Jayaram-Lindström, Nitya; Lindefeldt, Annika; Andersson, Maria; Brundin, Lou; Reid, Malcolm S; Franck, Johan

    2010-08-01

    The central nervous system-active medication acamprosate has been shown to modulate alcohol-related behavior in both preclinical and clinical studies. Although commonly used in the treatment of alcohol dependence, there are still unanswered questions concerning the pharmacokinetic properties of acamprosate. The aims of the present study were to 1) to validate liquid chromatography-mass spectrometry as a method to study the presence of acamprosate in plasma and cerebrospinal fluid (CSF) in humans; and 2) validate previous results on clinically important pharmacokinetic data for acamprosate. In an open label, single-site design, 13 healthy males and females were recruited to 22 days of oral acamprosate treatment (1998 mg/day). Subjects provided in all 256 plasma samples for analysis at regular intervals at Day 1, 7, 14, and 22 of treatment. On Day 22, subjects also left a sample of CSF for measurement of acamprosate. The results showed that steady-state level of acamprosate was accomplished within 5 days after the start of treatment and remained fairly stable for 2 to 3 days after termination of treatment. Variations in plasma concentrations corresponded to earlier studies and did not exceed those for comparable pharmacotherapeutic agents. Acamprosate concentrations in the CSF were below the limit of quantification, ie, estimated concentrations between 9 and 33 ng/mL. Plasma concentrations were more than 25 times higher than in lumbar CSF. The low CSF levels seen after 3 weeks of treatment may provide an explanation to the delay in therapeutic effect noticed in treatment studies on acamprosate. A longer duration of treatment might be necessary to obtain clinically significant brain levels of acamprosate. In summary, the present study validated liquid chromatography-mass spectrometry as a method for assessment of compliance to acamprosate treatment. Furthermore, the results suggest that the mechanism of action of acamprosate needs to be further explored with regard to the peripheral actions of the drug.

  19. LC-UV/MS methods for the analysis of prochelator - boronyl salicylaldehyde isonicotinoyl hydrazone (BSIH) and its active chelator salicylaldehyde isonicotinoyl hydrazone (SIH)

    PubMed Central

    Bureš, Jan; Jansová, Hana; Stariat, Ján; Filipský, Tomáš; Mladěnka, Přemysl; Šimůnek, Tomáš; Kučera, Radim; Klimeš, Jiří; Wang, Qin; Franz, Katherine J.; Kovaříková, Petra

    2015-01-01

    Salicylaldehyde isonicotinoyl hydrazone (SIH) is an intracellular iron chelator with well documented potential to protect against oxidative injury both in vitro and in vivo. However, it suffers from short biological half-life caused by fast hydrolysis of the hydrazone bond. Recently, a concept of boronate prochelators has been introduced as a strategy that might overcome these limitations. This study presents two complementary analytical methods for detecting the prochelator BSIH (boronyl salicylaldehyde isonicotinoyl hydrazone) along with its active metal-binding chelator SIH in different solution matrices and concentration ranges. An LC-UV method for determination of BSIH and SIH in buffer and cell culture medium was validated over concentrations of 7 – 115 and 4 – 115 μM, respectively, and applied to BSIH activation experiments in vitro. An LC-MS assay was validated for quantification of BSIH and SIH in plasma over the concentration range of 0.06 – 23 and 0.24 – 23 μM, respectively, and applied to stability studies in plasma in vitro as well as analysis of plasma taken after i.v. administration of BSIH to rats. A Zorbax-RP bonus column and mobile phases containing either phosphate buffer with EDTA or ammonium formate and methanol/acetonitrile mixture provided suitable conditions for the LC-UV and LC-MS analysis, respectively. Samples were diluted or precipitated with methanol prior to analysis. These separative analytical techniques establish the first validated protocols to investigate BSIH activation by hydrogen peroxide in multiple matrices, directly compare the stabilities of the prochelator and chelator in plasma, and provide the first basic pharmacokinetic data of this prochelator. Experiments reveal that BSIH is stable in all media tested and is partially converted to SIH by H2O2. The observed integrity of BSIH in plasma samples from the in vivo study suggest that the concept of prochelation might be a promising strategy for further development of aroylhydrazone cytoprotective agents. PMID:25527982

  20. Validated hydrophilic interaction LC-MS/MS method for simultaneous quantification of dacarbazine and 5-amino-4-imidazole-carboxamide in human plasma.

    PubMed

    Liu, Yanhong; Zhang, Weihua; Yang, Yuhui

    2008-10-19

    A hydrophilic interaction high performance liquid chromatography-tandem mass spectrometric method has been developed and validated for simultaneous quantification of dacarbazine (DTIC) and its terminal metabolite, 5-amino-4-imidazole-carboxamide (AIC) in human plasma. The plasma samples are first extracted by a C8+SCX mixed-mode 96-well plate to extend the extraction stability of DTIC and AIC. The extracted residues are further cleaned by a primary and secondary amine (PSA) adsorbent for minimization of matrix effect. Analyses are done on an Amide-80 HPLC column coupled to a tandem mass spectrometer fitted with an atmospheric pressure turbo ion spray ionization interface in the positive-ion mode. Both DTIC and AIC have reproducible retention times on the Amide-80 HPLC column. This type of column not only has an excellent column life (over 4000 injections), but also has zero carryover effect. The injection volume should be limited at 10 microL or less to avoid the peak splitting. The validated concentration ranges are from 0.5 to 500 ng/mL for DTIC and from 2.0 to 500 ng/mL for AIC. The validated method has been successfully applied to determine the pharmacokinetic profiles for human patients receiving DTIC infusions.

  1. Validation and Application of a Dried Blood Spot Ceftriaxone Assay

    PubMed Central

    Page-Sharp, Madhu; Nunn, Troy; Salman, Sam; Moore, Brioni R.; Batty, Kevin T.; Davis, Timothy M. E.

    2015-01-01

    Dried blood spot (DBS) antibiotic assays can facilitate pharmacokinetic/pharmacodynamic (PK/PD) studies in situations where venous blood sampling is logistically and/or ethically problematic. In this study, we aimed to develop, validate, and apply a DBS ceftriaxone assay. A liquid chromatography-tandem mass spectroscopy (LC-MS/MS) DBS ceftriaxone assay was assessed for matrix effects, process efficiency, recovery, variability, and limits of quantification (LOQ) and detection (LOD). The effects of hematocrit, protein binding, red cell partitioning, and chad positioning were evaluated, and thermal stability was assessed. Plasma, DBS, and cell pellet ceftriaxone concentrations in 10 healthy adults were compared, and plasma concentration-time profiles of DBS and plasma ceftriaxone were incorporated into population PK models. The LOQ and LOD for ceftriaxone in DBS were 0.14 mg/liter and 0.05 mg/liter, respectively. Adjusting for hematocrit, red cell partitioning, and relative recovery, DBS-predicted plasma concentrations were comparable to measured plasma concentrations (r > 0.95, P < 0.0001), and Bland-Altman plots showed no significant bias. The final population PK estimates of clearance, volume of distribution, and time above threshold MICs for measured and DBS-predicted plasma concentrations were similar. At 35°C, 21°C, 4°C, −20°C, and −80°C, ceftriaxone retained >95% initial concentrations in DBS for 14 h, 35 h, 30 days, 21 weeks, and >11 months, respectively. The present DBS ceftriaxone assay is robust and can be used as a surrogate for plasma concentrations to provide valid PK and PK/PD data in a variety of clinical situations, including in studies of young children and of those in remote or resource-poor settings. PMID:26438505

  2. Therapeutic drug monitoring of nevirapine in saliva in Uganda using high performance liquid chromatography and a low cost thin-layer chromatography technique.

    PubMed

    Lamorde, Mohammed; Fillekes, Quirine; Sigaloff, Kim; Kityo, Cissy; Buzibye, Allan; Kayiwa, Joshua; Merry, Concepta; Nakatudde-Katumba, Lillian; Burger, David; de Wit, Tobias F Rinke

    2014-09-01

    In resource limited settings access to laboratory monitoring of HIV treatment is limited and therapeutic drug monitoring is generally unavailable. This study aimed to evaluate nevirapine concentrations in saliva using low-cost thin-layer chromatography (TLC) and nevirapine concentrations in plasma and saliva using high performance liquid chromatography (HPLC) methods; and to correlate nevirapine plasma concentrations to HIV treatment outcomes in Ugandan patients. Paired plasma and stimulated saliva samples were obtained from Ugandan, HIV-infected adults on nevirapine-based ART. Nevirapine concentrations were measured using a validated HPLC method and a novel TLC method. Plasma nevirapine concentrations <3.0 mg/L using HPLC were considered subtherapeutic. Negative/positive predictive values of different thresholds for subtherapeutic nevirapine concentrations in saliva were determined. Virologic testing and, if applicable, HIV drug resistance testing was performed. Median (interquartile range, IQR) age of 297 patients was 39.1 (32.8-45.2) years. Three hundred saliva and 287 plasma samples were available for analysis. Attempts failed to determine nevirapine saliva concentrations by TLC. Using HPLC, median (IQR) nevirapine concentrations in saliva and plasma were 3.40 (2.59-4.47) mg/L and 6.17 (4.79-7.96) mg/L, respectively. The mean (coefficient of variation,%) nevirapine saliva/plasma ratio was 0.58 (62%). A cut-off value of 1.60 mg/L nevirapine in saliva was associated with a negative/positive predictive value of 0.99/0.72 and a sensitivity/specificity of 87%/98% for predicting subtherapeutic nevirapine plasma concentrations, respectively. Only 5% (15/287) of patients had subtherapeutic nevirapine plasma concentrations, of which 3 patients had viral load results > 400 copies/mL. Patients with nevirapine concentrations in plasma <3.0 mg/L had an Odds Ratio of 3.29 (95% CI: 1.00 - 10.74) for virological failure (viral load >400 copies/mL). The low-cost TLC technique for monitoring nevirapine in saliva was unsuccessful but monitoring nevirapine saliva and plasma concentrations using HPLC was shown to be feasible in the research/specialist context in Uganda. Further optimization and validation is required for the low-cost TLC technique.

  3. Evaluation of on-line desalter-inductively coupled plasma-mass spectrometry system for determination of Cr(III), Cr(VI), and total chromium concentrations in natural water and urine samples

    NASA Astrophysics Data System (ADS)

    Sun, Y. C.; Lin, C. Y.; Wu, S. F.; Chung, Y. T.

    2006-02-01

    We have developed a simple and convenient method for the determination of Cr(III), Cr(VI), and the total chromium concentrations in natural water and urine samples that use a flow injection on-line desalter-inductively coupled plasma-mass spectrometry system. When using aqueous ammonium chloride (pH 8) as the stripping solution, the severe interference from sodium in the matrix can be eliminated prior to inductively coupled plasma-mass spectrometry measurement, and the Cr(VI) level can be determined directly. To determine the total concentration of Cr in natural water and urine samples, we used H 2O 2 or HNO 3 to decompose the organic matter and convert all chromium species into the Cr(VI) oxidation state. To overcome the spectral interference caused by the matrix chloride ion in the resulting solutions, we employed cool plasma to successfully suppress chloride-based molecular ion interference during the inductively coupled plasma-mass spectrometry measurement. By significantly eliminating interference from the cationic and anionic components in the matrices prior to the inductively coupled plasma-mass spectrometry measurement, we found that the detection limit reached 0.18 μg L - 1 (based on 3 sigma). We validated this method through the analysis of the total chromium content in two reference materials (NIST 1643c and 2670E) and through measuring the recovery in spiked samples.

  4. Development and validation of a sensitive enzyme immunoassay (EIA) for blood plasma cortisol in female cattle, buffaloes, and goats.

    PubMed

    Yadav, R; Mohan, K; Kumar, V; Sarkar, M; Nitu, K; Meyer, H H D; Prakash, B S

    2013-08-01

    A highly sensitive enzyme immunoassay (EIA) that used the second antibody coating technique and the cortisol-horseradish peroxidase conjugate as a label for determination of free and total cortisol in blood plasma of dairy animals (cows, buffaloes, and goats) was developed. For biological validation of the EIA, blood samples were collected from the animals at 48 and 24 h before and 0, 12, 24, 36, 48, 60, 72, 84, 96, 108, 120, and 132 h after dexamethasone administration. The EIA was performed directly with 20 μL of fresh plasma (for free cortisol) and also with 20 μL of heat-treated plasma (for total cortisol) after 1:5 dilutions with PBS. Cortisol standards ranging from 0.39 to 200 pg/well/20 μL were used, and the sensitivity of the EIA procedure was found to be 0.39 pg/well/20 μL, which corresponded to 0.02 ng/mL. In comparison with RIA the EIA was at least 4 times more sensitive and required 5 times less cortisol antiserum. In female cattle, buffaloes, and goats, the total, free, and bound plasma cortisol before dexamethasone administration was significantly (P < 0.05) higher than the total, free, and bound cortisol after dexamethasone administration. It can be concluded from these studies that the direct, sensitive EIA validated for estimating the free and total cortisol concentrations was sufficiently reliable and quick for studying the dynamics of cortisol distribution in blood plasma of dairy animals. Copyright © 2013 Elsevier Inc. All rights reserved.

  5. Bioanalytical LC-MS/MS method validation for plasma determination of topiramate in healthy Indian volunteers.

    PubMed

    Goswami, Dipanjan; Kumar, Ajay; Khuroo, Arshad H; Monif, Tausif; Rab, Shamsur

    2009-11-01

    A LC-MS/MS method for plasma topiramate analysis is delineated involving least number of healthy volunteers. Topiramate and amlodipine internal standard (IS) were extracted by simple centrifuge-coupled solid-phase extraction and reverse-phase chromatographic separation was performed on an Ascentis C(18) column. Turbo-spray negative-ion mode multiple-reaction monitoring was selected for mass pair detection at m/z 338.3 --> 78.0 and m/z 407.3 --> 295.5 for analyte and IS respectively. The method showed a dynamic linearity range from 10.4 to 2045.0 ng/mL, lower limit of quantitation achieved at 10.4 ng/mL and finally a mass spectrometric total run time of within 2.5 min for human sample analysis. Bioequivalence was assessed successfully using this fully validated method on 16 fasted Indian male subjects with 25 mg topiramate tablet administration. An appropriate study design describes plasma samples collection up to 216 h post dose in two periods, separated by a 28 day washout period. The challenge of half-life matching for test and reference drug was achieved with 73.43 +/- 9.68 and 73.06 +/- 14.03 h, respectively, and intra-subject coefficient of variation achieved within 11% for AUCs and C(max) evaluated by non-compartmental pharmacokinetic analysis. The results of LCMS topiramate complete method validation supported by pharmacokinetic study have not been published before, and are presented and discussed for the first time in this article. Copyright (c) 2009 John Wiley & Sons, Ltd.

  6. Validation of high-throughput methods for measuring blood urea nitrogen and urinary albumin concentrations in mice.

    PubMed

    Grindle, Susan; Garganta, Cheryl; Sheehan, Susan; Gile, Joe; Lapierre, Andree; Whitmore, Harry; Paigen, Beverly; DiPetrillo, Keith

    2006-12-01

    Chronic kidney disease is a substantial medical and economic burden. Animal models, including mice, are a crucial component of kidney disease research; however, recent studies disprove the ability of autoanalyzer methods to accurately quantify plasma creatinine levels, an established marker of kidney disease, in mice. Therefore, we validated autoanalyzer methods for measuring blood urea nitrogen (BUN) and urinary albumin concentrations, 2 common markers of kidney disease, in samples from mice. We used high-performance liquid chromatography to validate BUN concentrations measured using an autoanalyzer, and we utilized mouse albumin standards to determine the accuracy of the autoanalyzer over a wide range of albumin concentrations. We observed a significant, linear correlation between BUN concentrations measured by autoanalyzer and high-performance liquid chromatography. We also found a linear relationship between known and measured albumin concentrations, although the autoanalyzer method underestimated the known amount of albumin by 3.5- to 4-fold. We confirmed that plasma and urine constituents do not interfere with the autoanalyzer methods for measuring BUN and urinary albumin concentrations. In addition, we verified BUN and albuminuria as useful markers to detect kidney disease in aged mice and mice with 5/6-nephrectomy. We conclude that autoanalyzer methods are suitable for high-throughput analysis of BUN and albumin concentrations in mice. The autoanalyzer accurately quantifies BUN concentrations in mouse plasma samples and is useful for measuring urinary albumin concentrations when used with mouse albumin standards.

  7. Development and validation of a high-performance liquid chromatography method for determination of cefquinome concentrations in sheep plasma and its application to pharmacokinetic studies.

    PubMed

    Uney, Kamil; Altan, Feray; Elmas, Muammer

    2011-02-01

    Cefquinome has a broad spectrum of antibacterial activity and was developed especially for use in animals. A simple and sensitive high-performance liquid chromatography (HPLC) method with UV-visible detection for quantification of cefquinome concentrations in sheep plasma was developed and validated. Separation of cefquinome from plasma components was achieved on a Phenomenex Gemini C(18) column (250 mm by 4.6 mm; internal diameter [i.d.], 5 μm). The mobile phase consisted of acetonitrile and 0.1% trifluoroacetic acid in water and was delivered at a rate of 0.9 ml/min. A simple and rapid sample preparation involved the addition of methanol to 200 μl of plasma to precipitate plasma proteins followed by direct injection of 50 μl of supernatant into the high-performance liquid chromatography system. The linearity range of the proposed method was 0.02 to 12 μg/ml. The intraday and interday coefficients of variation obtained from cefquinome were less than 5%, and biases ranged from -3.76% to 1.24%. Mean recovery based on low-, medium-, and high-quality control standards ranged between 92.0 and 93.9%. Plasma samples were found to be stable in various storage conditions (freeze-thaw, postpreparative, short-term, and long-term stability). The method described was found to be readily available, practicable, cheap, rapid, sensitive, precise, and accurate. It was successfully applied to the study of the pharmacokinetics of cefquinome in sheep. This method can be very useful and an alternate to performing pharmacokinetic studies in the determination of cefquinome for clinical use.

  8. Simultaneous determination of parecoxib sodium and its active metabolite valdecoxib in rat plasma by UPLC-MS/MS and its application to a pharmacokinetic study after intravenous and intramuscular administration.

    PubMed

    Liu, Meina; Yu, Qiuyang; Li, Ping; Zhu, Meng; Fang, Mingming; Sun, Bingjun; Sun, Mengchi; Sun, Yinghua; Zhang, Peng; He, Zhonggui; Sun, Jin; Wang, Yongjun; Liu, Xiaohong

    2016-06-01

    In this study, we developed and validated a new, rapid, specific and sensitive ultra-performance liquid chromatography-tandem mass spectrometric (UPLC-MS/MS) method to simultaneously determine parecoxib sodium (PX) and its active metabolite, valdecoxib (VX), in rat plasma. Plasma samples were prepared by plasma protein precipitation combined with a liquid-liquid extraction method. The separation was carried out on a Kinetex C18 column (2.1mm×50mm, 2.6μm) with a gradient elution using methanol (A) and a 2mM ammonium acetate aqueous solution (B). The analysis was performed in less than 3min with a flow rate of 0.2mL/min. Ketoprofen was used as an internal standard (IS). Mass spectrometric detection was conducted with a triple quadrupole detector equipped with electrospray ionization in the negative ion mode (ESI(-)) using multiple reaction monitoring (MRM). The calibration curves were linear over the concentration ranges of 5-4000ng/mL for PX and 5-2000ng/mL for VX with all correlation coefficients greater than 0.998. The intra- and inter-day relative standard deviations (RSD) for both analytes were within 15% and the accuracy was within 85-115% at all quality control levels. The mean extraction recoveries for all analytes obtained from three concentrations of QC plasma samples were more than 89.0% efficient. Selectivity, matrix effect, dilution integrity and stability were also validated. The method was successfully used to investigate the pharmacokinetics of PX and VX in rat plasma after intravenous and intramuscular administration of PX. Copyright © 2016 Elsevier B.V. All rights reserved.

  9. LC-MS-MS simultaneous determination of atorvastatin and ezetimibe in human plasma.

    PubMed

    El-Bagary, Ramzia I; Elkady, Ehab F; El-Sherif, Zeinab Abdelaziz; Kadry, Ahmed M

    2014-09-01

    Atorvastatin and ezetimibe are lipid-lowering drugs prescribed for the treatment of hypercholesterolemia. An LC-MS-MS method has been developed and validated for the simultaneous estimation of atorvastatin and ezetimibe in human plasma using pitavastatin as an internal standard. Liquid-liquid extraction was used for the purification and preconcentration of analytes from human plasma matrix. The chromatographic separation was achieved within 3.0 min by an isocratic mobile phase consisting of 0.2% formic acid in water-acetonitrile (30:70, v/v), flowing through Agilent Eclipse-plus C18, 100 × 4.6 mm, 3.5 µm analytical column, at a flow rate of 0.6 mL min(-1). Multiple reaction monitoring transitions were measured in the positive ion mode for atorvastatin and internal standard, while ezetimibe was measured in negative ion mode. A detailed validation of the method was performed as per US-FDA guidelines and the standard curves were found to be linear in the range of 0.2-30.0 ng mL(-1) with a mean correlation coefficient >0.999 for both drugs. In human plasma, atorvastatin and ezetimibe were stable for at least 36 days at -70 ± 5 °C and 6 h at ambient temperature. After extraction from plasma, the reconstituted samples of atorvastatin and ezetimibe were stable in an autosampler at ambient temperature for 6 h. Also, the cited drugs were stable in plasma samples upon subjecting to three freeze thaw cycles. The method is simple, specific, sensitive, precise, accurate and suitable for bioequivalence and pharmacokinetic studies of this combination. © The Author [2013]. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.

  10. Proteomic-Biostatistic Integrated Approach for Finding the Underlying Molecular Determinants of Hypertension in Human Plasma.

    PubMed

    Gajjala, Prathibha R; Jankowski, Vera; Heinze, Georg; Bilo, Grzegorz; Zanchetti, Alberto; Noels, Heidi; Liehn, Elisa; Perco, Paul; Schulz, Anna; Delles, Christian; Kork, Felix; Biessen, Erik; Narkiewicz, Krzysztof; Kawecka-Jaszcz, Kalina; Floege, Juergen; Soranna, Davide; Zidek, Walter; Jankowski, Joachim

    2017-08-01

    Despite advancements in lowering blood pressure, the best approach to lower it remains controversial because of the lack of information on the molecular basis of hypertension. We, therefore, performed plasma proteomics of plasma from patients with hypertension to identify molecular determinants detectable in these subjects but not in controls and vice versa. Plasma samples from hypertensive subjects (cases; n=118) and controls (n=85) from the InGenious HyperCare cohort were used for this study and performed mass spectrometric analysis. Using biostatistical methods, plasma peptides specific for hypertension were identified, and a model was developed using least absolute shrinkage and selection operator logistic regression. The underlying peptides were identified and sequenced off-line using matrix-assisted laser desorption ionization orbitrap mass spectrometry. By comparison of the molecular composition of the plasma samples, 27 molecular determinants were identified differently expressed in cases from controls. Seventy percent of the molecular determinants selected were found to occur less likely in hypertensive patients. In cross-validation, the overall R 2 was 0.434, and the area under the curve was 0.891 with 95% confidence interval 0.8482 to 0.9349, P <0.0001. The mean values of the cross-validated proteomic score of normotensive and hypertensive patients were found to be -2.007±0.3568 and 3.383±0.2643, respectively, P <0.0001. The molecular determinants were successfully identified, and the proteomic model developed shows an excellent discriminatory ability between hypertensives and normotensives. The identified molecular determinants may be the starting point for further studies to clarify the molecular causes of hypertension. © 2017 American Heart Association, Inc.

  11. A Validated UPLC-MS-MS Assay for the Rapid Determination of Lorcaserin in Plasma and Brain Tissue Samples.

    PubMed

    Bajrai, Amal A; Ezzeldin, Essam; Al-Rashood, Khalid A; Raish, Mohammad; Iqbal, Muzaffar

    2016-03-01

    Lorcaserin is a novel, potent and highly efficacious 5-HT2C receptor agonist, recently approved by US Food and Drug Administration for the treatment of obesity. It has some abuse potential also and is listed as a Schedule IV drug in the Controlled Substances Act. Herein, a sensitive, selective and reliable UPLC-MS-MS assay was developed and validated for the quantitative analysis of lorcaserin in rat plasma and brain tissue using carbamazepine as an internal standard (IS). After the extraction of samples by protein precipitation, both lorcaserin and IS were separated on an Acquity BEH™ C18 (50 × 2.1 mm, 1.7 µm) column using a mobile phase consisting of acetonitrile-10 mM ammonium acetate-formic acid (85:15:0.1, v/v/v) at a flow rate of 0.25 mL/min. Detection and quantification were performed on a positive electrospray ionization interface in the multiple-reaction monitoring (MRM) mode. The MS-MS ion transitions were monitored at m/z 195.99 > 143.91 for lorcaserin and m/z 237.00 > 178.97 for IS, respectively. The calibration curves were linear over a concentration range of 1.08-500 ng/mL in plasma and 3.07-500 ng/mL in brain tissue homogenates, respectively. All the validation parameters results were within the acceptable range described in guidelines for bioanalytical method validation. The assay was successfully applied in a pharmacokinetic study of lorcaserin after oral administration in rats. © The Author 2015. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.

  12. Validation and Application of a Dried Blood Spot Assay for Biofilm-Active Antibiotics Commonly Used for Treatment of Prosthetic Implant Infections

    PubMed Central

    Knippenberg, Ben; Page-Sharp, Madhu; Clark, Ben; Dyer, John; Batty, Kevin T.; Davis, Timothy M. E.

    2016-01-01

    Dried blood spot (DBS) antibiotic assays can facilitate pharmacokinetic (PK)/pharmacodynamic (PD) studies in situations where venous blood sampling is logistically difficult. We sought to develop, validate, and apply a DBS assay for rifampin (RIF), fusidic acid (FUS), and ciprofloxacin (CIP). These antibiotics are considered active against organisms in biofilms and are therefore commonly used for the treatment of infections associated with prosthetic implants. A liquid chromatography-mass spectroscopy DBS assay was developed and validated, including red cell partitioning and thermal stability for each drug and the rifampin metabolite desacetyl rifampin (Des-RIF). Plasma and DBS concentrations in 10 healthy adults were compared, and the concentration-time profiles were incorporated into population PK models. The limits of quantification for RIF, Des-RIF, CIP, and FUS in DBS were 15 μg/liter, 14 μg/liter, 25 μg/liter, and 153 μg/liter, respectively. Adjusting for hematocrit, red cell partitioning, and relative recovery, DBS-predicted plasma concentrations were comparable to measured plasma concentrations for each antibiotic (r > 0.95; P < 0.0001), and Bland-Altman plots showed no significant bias. The final population PK estimates of clearance, volume of distribution, and time above threshold MICs for measured and DBS-predicted plasma concentrations were comparable. These drugs were stable in DBSs for at least 10 days at room temperature and 1 month at 4°C. The present DBS antibiotic assays are robust and can be used as surrogates for plasma concentrations to provide valid PK and PK/PD data in a variety of clinical situations, including therapeutic drug monitoring or studies of implant infections. PMID:27270283

  13. Development and validation of a high-performance liquid chromatography-tandem mass spectrometry assay quantifying vemurafenib in human plasma.

    PubMed

    Nijenhuis, C M; Rosing, H; Schellens, J H M; Beijnen, J H

    2014-01-01

    Vemurafenib is an inhibitor of mutated serine/threonine-protein kinase B-Raf (BRAF) and is registered as Zelboraf(®) for the treatment of adult patients with BRAF V600 mutation-positive unresectable or metastatic melanoma. To support Therapeutic Drug Monitoring (TDM) and clinical trials, we developed and validated a method for the quantification of vemurafenib in human plasma. Additionally two LC-MS systems with different detectors were tested: the TSQ Quantum Ultra and the API3000. Human plasma samples were collected in the clinic and stored at nominally -20°C. Vemurafenib was isolated from plasma by liquid-liquid extraction, separated on a C18 column with gradient elution, and analysed with triple quadrupole mass spectrometry in positive-ion mode. A stable isotope was used as internal standard for the quantification. Ranging from 1 to 100μg/ml the assay was linear with correlation coefficients (r(2)) of 0.9985 or better. Inter-assay and intra-assay accuracies were within ±7.6% of the nominal concentration; inter-assay and intra-assay precision were within ≤9.3% of the nominal concentration. In addition all results were within the acceptance criteria of the US FDA and the latest EMA guidelines for method validation for both MS detectors. In conclusion, the presented analytical method for vemurafenib in human plasma was successfully validated and the performance of the two LC-MS systems for this assay was comparable. In addition the method was successfully applied to evaluate the pharmacokinetic quantification of vemurafenib in cancer patients treated with vemurafenib. Copyright © 2013 Elsevier B.V. All rights reserved.

  14. Therapeutic drug monitoring of seven psychotropic drugs and four metabolites in human plasma by HPLC-MS.

    PubMed

    Choong, Eva; Rudaz, Serge; Kottelat, Astrid; Guillarme, Davy; Veuthey, Jean-Luc; Eap, Chin B

    2009-12-05

    A simple and sensitive LC-MS method was developed and validated for the simultaneous quantification of aripiprazole (ARI), atomoxetine (ATO), duloxetine (DUL), clozapine (CLO), olanzapine (OLA), sertindole (STN), venlafaxine (VEN) and their active metabolites dehydroaripiprazole (DARI), norclozapine (NCLO), dehydrosertindole (DSTN) and O-desmethylvenlafaxine (OVEN) in human plasma. The above mentioned compounds and the internal standard (remoxipride) were extracted from 0.5 mL plasma by solid-phase extraction (mix mode support). The analytical separation was carried out on a reverse phase liquid chromatography at basic pH (pH 8.1) in gradient mode. All analytes were monitored by MS detection in the single ion monitoring mode and the method was validated covering the corresponding therapeutic range: 2-200 ng/mL for DUL, OLA, and STN, 4-200 ng/mL for DSTN, 5-1000 ng/mL for ARI, DARI and finally 2-1000 ng/mL for ATO, CLO, NCLO, VEN, OVEN. For all investigated compounds, good performance in terms of recoveries, selectivity, stability, repeatability, intermediate precision, trueness and accuracy, was obtained. Real patient plasma samples were then successfully analysed.

  15. A 96-well screen filter plate for high-throughput biological sample preparation and LC-MS/MS analysis.

    PubMed

    Peng, Sean X; Cousineau, Martin; Juzwin, Stephen J; Ritchie, David M

    2006-01-01

    A novel 96-well screen filter plate (patent pending) has been invented to eliminate a time-consuming and labor-intensive step in preparation of in vivo study samples--to remove blood or plasma clots. These clots plug the pipet tips during a manual or automated sample-transfer step causing inaccurate pipetting or total pipetting failure. Traditionally, these blood and plasma clots are removed by picking them out manually one by one from each sample tube before any sample transfer can be made. This has significantly slowed the sample preparation process and has become a bottleneck for automated high-throughput sample preparation using robotic liquid handlers. Our novel screen filter plate was developed to solve this problem. The 96-well screen filter plate consists of 96 stainless steel wire-mesh screen tubes connected to the 96 openings of a top plate so that the screen filter plate can be readily inserted into a 96-well sample storage plate. Upon insertion, the blood and plasma clots are excluded from entering the screen tube while clear sample solutions flow freely into it. In this way, sample transfer can be easily completed by either manual or automated pipetting methods. In this report, three structurally diverse compounds were selected to evaluate and validate the use of the screen filter plate. The plasma samples of these compounds were transferred and processed in the presence and absence of the screen filter plate and then analyzed by LC-MS/MS methods. Our results showed a good agreement between the samples prepared with and without the screen filter plate, demonstrating the utility and efficiency of this novel device for preparation of blood and plasma samples. The device is simple, easy to use, and reusable. It can be employed for sample preparation of other biological fluids that contain floating particulates or aggregates.

  16. HPLC Plasma Assay of a Novel Anti-MRSA Compound, Kaempferol-3-O-Alpha-L-(2",3"-di-p-coumaroyl)rhamnoside, from Sycamore Leaves.

    PubMed

    Zhang, Yiguan; Valeriote, Frederick; Swartz, Kenneth; Chen, Ben; Hamann, Mark T; Rodenburg, Douglas L; McChesney, James D; Shaw, Jiajiu

    2015-08-01

    Methicillin-resistant Staphylococcus aureus (MRSA) is a serious pathogen that is resistant to current antibiotic therapy. Thus, there is an urgent need for novel antimicrobial agents that can effectively combat these new strains of drug-resistant "superbugs". Recently, fractionation of an extract from Platanus occidentalis (American sycamore) leaves produced an active kaempferol molecule, 3-O-alpha-L-(2",3"-di-p-coumaroyl)rhamnoside (KCR), in four isomeric forms; all four isomers exhibit potent anti-MRSA activity. In order to further the preclinical development of KCR as a new antibiotic class, we developed and validated a simple analytical method for assaying KCR plasma concentration. Because KCR will be developed as a new drug, although comprising four stereoisomers, the analytical method was devised to assay the total amount of all four isomers. In the present work, both a plasma processing procedure and an HPLC method have been developed and validated. Mouse plasma containing KCR was first treated with ethanol and then centrifuged. The supernatant was dried, suspended in ethanol, centrifuged, and the supernatant was injected into an HPLC system comprising a Waters C18, a mobile phase composing methanol, acetonitrile, and trifluoroacetic acid and monitored at 313 nm. The method was validated by parameters including a good linear correlation, a limit of quantification of 0.27 microg/mL, and high accuracy. In summary, this method allows a rapid analysis of KCR in the plasma samples for pharmacokinetics studies.

  17. Simultaneous quantification of paeoniflorin, nobiletin, tangeretin, liquiritigenin, isoliquiritigenin, liquiritin and formononetin from Si-Ni-San extract in rat plasma and tissues by liquid chromatography-tandem mass spectrometry.

    PubMed

    Li, Tianxue; Yan, Zhixiang; Zhou, Chen; Sun, Jian; Jiang, Chuan; Yang, Xinghao

    2013-08-01

    In this study, a sensitive and reliable liquid chromatography-tandem mass spectrometry (LC-MS/MS) method was developed and validated for the determination of seven bioactive components including paeoniflorin, nobiletin, tangeretin, liquiritigenin, isoliquiritigenin, liquiritin and formononetin in rat plasma and tissues after oral administration of Si-Ni-San extract using astragaloside IV as internal standard (IS). The plasma and tissue samples were extracted by solid-phase extraction. Chromatographic separation was accomplished on a C18 column with a multiple-step gradient elution. The quantification was obtained by scanning with multiple reaction monitoring via an electrospray ionization source that was operated by switching between the positive and negative modes in two MS/MS scan segments. Full validation of the assay was implemented. In conclusion, this method demonstrated good linearity and specificity. The lower limits of quantification for the analytes were <7.5 ng/mL. Intra- and inter-day precisions (RSD) were <12.5% and accuracy (RE) ranged from -10.2 to 7.3%. The average recoveries of the analytes from rat plasma and tissues were >65.2% and 58.6%, respectively. The validated method was further applied to the determination of actual rat plasma and tissues after oral administration of Si-Ni-San extract. The results provided a meaningful basis for the clinical application of this prescription. Copyright © 2013 John Wiley & Sons, Ltd.

  18. HPLC Plasma Assay of a Novel Anti-MRSA Compound, Kaempferol-3-O-Alpha-L-(2",3"-di-p-coumaroyl)rhamnoside, from Sycamore Leaves

    PubMed Central

    Zhang, Yiguan; Valeriote, Frederick; Swartz, Kenneth; Chen, Ben; Hamann, Mark T.; Rodenburg, Douglas L.; McChesney, James D.

    2016-01-01

    Methicillin-resistant Staphylococcus aureus (MRSA) is a serious pathogen that is resistant to current antibiotic therapy. Thus, there is an urgent need for novel antimicrobial agents that can effectively combat these new strains of drug-resistant “superbugs”. Recently, fractionation of an extract from Platanus occidentalis (American sycamore) leaves produced an active kaempferol molecule, 3-O-alpha-L-(2",3"-di-p-coumaroyl)rhamnoside (KCR), in four isomeric forms; all four isomers exhibit potent anti-MRSA activity. In order to further the preclinical development of KCR as a new antibiotic class, we developed and validated a simple analytical method for assaying KCR plasma concentration. Because KCR will be developed as a new drug, although comprising four stereoisomers, the analytical method was devised to assay the total amount of all four isomers. In the present work, both a plasma processing procedure and an HPLC method have been developed and validated. Mouse plasma containing KCR was first treated with ethanol and then centrifuged. The supernatant was dried, suspended in ethanol, centrifuged, and the supernatant was injected into an HPLC system comprising a Waters C18, a mobile phase composing methanol, acetonitrile, and trifluoroacetic acid and monitored at 313 nm. The method was validated by parameters including a good linear correlation, a limit of quantification of 0.27 µg/mL, and high accuracy. In summary, this method allows a rapid analysis of KCR in the plasma samples for pharmacokinetics studies. PMID:26434123

  19. Multielemental analysis of prehistoric animal teeth by laser-induced breakdown spectroscopy and laser ablation inductively coupled plasma mass spectrometry

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Galiova, Michaela; Kaiser, Jozef; Fortes, Francisco J.

    2010-05-01

    Laser-induced breakdown spectroscopy (LIBS) and laser ablation (LA) inductively coupled plasma (ICP) mass spectrometry (MS) were utilized for microspatial analyses of a prehistoric bear (Ursus arctos) tooth dentine. The distribution of selected trace elements (Sr, Ba, Fe) was measured on a 26 mmx15 mm large and 3 mm thick transverse cross section of a canine tooth. The Na and Mg content together with the distribution of matrix elements (Ca, P) was also monitored within this area. The depth of the LIBS craters was measured with an optical profilometer. As shown, both LIBS and LA-ICP-MS can be successfully used for themore » fast, spatially resolved analysis of prehistoric teeth samples. In addition to microchemical analysis, the sample hardness was calculated using LIBS plasma ionic-to-atomic line intensity ratios of Mg (or Ca). To validate the sample hardness calculations, the hardness was also measured with a Vickers microhardness tester.« less

  20. BRSCW Reference Set Application: Karen Abbott -University of Arkansas (2014) — EDRN Public Portal

    Cancer.gov

    Our earlier glycoproteomic studies have identified bisecting glycoslyation and core fucosylation changes on particular glycoproteins in endometrioid ovarian cancer tissues and plasma (Abbott et al, 2010, Proteomics). We have validated that these glycan changes occur on the same glycoproteins in serous ovarian cancer plasma using a lectin-pull down western blot assays. We would like to used pooled reference samples to develop a sensitive magnetic bead-based assay to detect these glycoproteins with bisecting and core fucosylation changes.

  1. Quantification of ethanol in plasma by electrochemical detection with an unmodified screen printed carbon electrode

    NASA Astrophysics Data System (ADS)

    Tian, Gang; Zhang, Xiao-Qing; Zhu, Ming-Song; Zhang, Zhong; Shi, Zheng-Hu; Ding, Min

    2016-03-01

    Simple, rapid and accurate detection of ethanol concentration in blood is very crucial in the diagnosis and management of potential acute ethanol intoxication patients. A novel electrochemical detection method was developed for the quantification of ethanol in human plasma with disposable unmodified screen-printed carbon electrode (SPCE) without sample preparation procedure. Ethanol was detected indirectly by the reaction product of ethanol dehydrogenase (ADH) and cofactor nicotinamide adenine dinucleotide (NAD+). Method validation indicated good quantitation precisions with intra-day and inter-day relative standard deviations of ≤9.4% and 8.0%, respectively. Ethanol concentration in plasma is linear ranging from 0.10 to 3.20 mg/mL, and the detection limit is 40.0 μg/mL (S/N > 3). The method shows satisfactory correlation with the reference method of headspace gas chromatography in twenty human plasma samples (correlation coefficient 0.9311). The proposed method could be applied to diagnose acute ethanol toxicity or ethanol-related death.

  2. Quantification of ethanol in plasma by electrochemical detection with an unmodified screen printed carbon electrode

    PubMed Central

    Tian, Gang; Zhang, Xiao-Qing; Zhu, Ming-Song; Zhang, Zhong; Shi, Zheng-Hu; Ding, Min

    2016-01-01

    Simple, rapid and accurate detection of ethanol concentration in blood is very crucial in the diagnosis and management of potential acute ethanol intoxication patients. A novel electrochemical detection method was developed for the quantification of ethanol in human plasma with disposable unmodified screen-printed carbon electrode (SPCE) without sample preparation procedure. Ethanol was detected indirectly by the reaction product of ethanol dehydrogenase (ADH) and cofactor nicotinamide adenine dinucleotide (NAD+). Method validation indicated good quantitation precisions with intra-day and inter-day relative standard deviations of ≤9.4% and 8.0%, respectively. Ethanol concentration in plasma is linear ranging from 0.10 to 3.20 mg/mL, and the detection limit is 40.0 μg/mL (S/N > 3). The method shows satisfactory correlation with the reference method of headspace gas chromatography in twenty human plasma samples (correlation coefficient 0.9311). The proposed method could be applied to diagnose acute ethanol toxicity or ethanol-related death. PMID:27006081

  3. Development and validation of a sensitive assay for analysis of midazolam, free and conjugated 1-hydroxymidazolam and 4-hydroxymidazolam in pediatric plasma: Application to Pediatric Pharmacokinetic Study.

    PubMed

    Moorthy, Ganesh S; Jogiraju, Harini; Vedar, Christina; Zuppa, Athena F

    2017-11-01

    Pharmacokinetic, pharmacodynamic and pharmacogenomic studies of midazolam are currently being performed in critically ill children to find suitable dose regimens. Sensitive assays using small volumes of plasma are necessary to determine the concentrations of midazolam and its respective metabolites in pediatric studies. Midazolam is metabolized to hydroxylated midazolam isomers, which are present as free as well as the corresponding glucuronide conjugates. A high-performance liquid chromatographic method with tandem mass spectrometry has been developed and validated for the quantification of midazolam, and free and total 1-hydroxymidazolam and 4-hydroxymidazolam metabolites in small volumes of plasma. Cleanup consisted of 96-well μ-elution solid phase extraction (SPE). The analytes were separated by gradient elution using a C 18 analytical column with a total run time of 5min. Multiple reaction monitoring was employed using precursor to product ion transitions of m/z 326.2→291.3 for midazolam, m/z 342.1→203.0 for 1-hydroxymidazolam, m/z 342.1→325.1 for 4-hydroxymidazolam and m/z 330.2→295.3 for 2 H 4 -midazolam (internal standard). Since authentic hydroxymidazolamglucuronide standards are not available, samples were hydrolyzed with β-glucuronidase under optimized conditions. Assay conditions were modified and optimized to provide appropriate recovery and stability because 4-hydroxymidazolam was very acid sensitive. Standard curves were linear from 0.5 to 1000ng/mL for all three analytes. Intra- and inter day accuracy and precision for quality control samples (2, 20, 200 and 800ng/mL) were within 85-115% and 15% (coefficient of variation), respectively. Stability in plasma and extracts were sufficient under assay conditions. Plasma samples were processed and analyzed for midazolam, and free 1-hydroxymidazolam and 4-hydroxymidazolam metabolites. Plasma samples that were hydrolyzed with β-glucuronidase were processed and analyzed for midazolam, and total 1-hydroxymidazolam and 4-hydroxymidazolam metabolites under the same assay conditions. The difference in concentration between the total and free hydroxymidazolam metabolites provided an estimate of conjugated hydroxymidazolam metabolites. The combination of 96-well μ-elution SPE and LC-MS/MS allows reliable quantification of midazolam and its metabolites in small volumes of plasma for pediatric patients. This assay is currently being successfully utilized for analysis of samples from ongoing clinical trials. Copyright © 2017 Elsevier B.V. All rights reserved.

  4. Association between the miRNA signatures in plasma and bronchoalveolar fluid in respiratory pathologies.

    PubMed

    Molina-Pinelo, Sonia; Suárez, Rocío; Pastor, María Dolores; Nogal, Ana; Márquez-Martín, Eduardo; Martín-Juan, José; Carnero, Amancio; Paz-Ares, Luis

    2012-01-01

    The identification of new less invasive biomarkers is necessary to improve the detection and prognostic outcome of respiratory pathological processes. The measurement of miRNA expression through less invasive techniques such as plasma and serum have been suggested to analysis of several lung malignancies including lung cancer. These studies are assuming a common deregulated miRNA expression both in blood and lung tissue. The present study aimed to obtain miRNA representative signatures both in plasma and bronchoalveolar cell fraction that could serve as biomarker in respiratory diseases. Ten patients were evaluated to assess the expression levels of 381 miRNAs. We found that around 50% miRNAs were no detected in both plasma and bronchoalveolar cell fraction and only 20% of miRNAs showed similar expression in both samples. These results show a lack of association of miRNA signatures between plasma and bronchoalveolar cytology in the same patient. The profiles are not comparable; however, there is a similarity in the relative expression in a very small subset of miRNAs (miR-17, miR-19b, miR-195 and miR-20b) between both biological samples in all patients. This finding supports that the miRNAs profiles obtained from different biological samples have to be carefully validated to link with respiratory diseases.

  5. Validation of an optimized method for the determination of iodine in human breast milk by inductively coupled plasma mass spectrometry (ICPMS) after tetramethylammonium hydroxide extraction.

    PubMed

    Huynh, Dao; Zhou, Shao Jia; Gibson, Robert; Palmer, Lyndon; Muhlhausler, Beverly

    2015-01-01

    In this study a novel method to determine iodine concentrations in human breast milk was developed and validated. The iodine was analyzed by inductively coupled plasma mass spectrometry (ICPMS) following tetramethylammonium hydroxide (TMAH) extraction at 90°C in disposable polypropylene tubes. While similar approaches have been used previously, this method adopted a shorter extraction time (1h vs. 3h) and used antimony (Sb) as the internal standard, which exhibited greater stability in breast milk and milk powder matrices compared to tellurium (Te). Method validation included: defining iodine linearity up to 200μgL(-1); confirming recovery of iodine from NIST 1549 milk powder. A recovery of 94-98% was also achieved for the NIST 1549 milk powder and human breast milk samples spiked with sodium iodide and thyroxine (T4) solutions. The method quantitation limit (MQL) for human breast milk was 1.6μgL(-1). The intra-assay and inter-assay coefficient of variation for the breast milk samples and NIST powder were <1% and <3.5%, respectively. NIST 1549 milk powder, human breast milk samples and calibration standards spiked with the internal standard were all stable for at least 2.5 months after extraction. The results of the validation process confirmed that this newly developed method provides greater accuracy and precision in the assessment of iodine concentrations in human breast milk than previous methods and therefore offers a more reliable approach for assessing iodine concentrations in human breast milk. Copyright © 2014 Elsevier GmbH. All rights reserved.

  6. A new LC-MS/MS bioanalytical method for atenolol in human plasma and milk.

    PubMed

    Phyo Lwin, Ei Mon; Gerber, Cobus; Song, Yunmei; Leggett, Catherine; Ritchie, Usha; Turner, Sean; Garg, Sanjay

    2017-04-01

    A new sensitive LC-MS/MS method for the quantification of atenolol in human plasma and milk has been developed for clinical lactation studies. Atenolol and the internal standard, phenazone, were extracted from biological matrices by protein precipitation. A Phenomenex ® C-18 column and gradient chromatographic conditions were used for separation of the analyte, followed by detection with MS. Stability of samples was confirmed for atenolol in human plasma and milk for up to 3 months. Linearity range of 1-800 ng/ml (r 2 = 0.9995), the precision within 15% CV and the recovery of the analyte (80-100% range) were achieved. A new validated analytical method for atenolol in plasma and milk was developed.

  7. Regulated bioanalysis of conformers - A case study with ASP2151 in dog plasma and urine.

    PubMed

    Ohtsu, Yoshiaki; Otsuka, Shohei; Nakamura, Takeshi; Noguchi, Kiyoshi

    2015-08-01

    We developed and validated bioanalytical methods for a potent helicase-primase inhibitor ASP2151 that has two conformers. These conformers elute as unseparated broad peaks under ordinary high-performance liquid chromatographic conditions, indicating discernable differences in hydrophobicity. We observed that column temperature and mobile phase pH have no effect on these peaks and that conformers form a single symmetrical peak when tetrahydrofuran is added to the mobile phase. In addition, we needed to develop semi-automated methods where inter-conversion of the conformers is unlikely to cause sample-to-sample extraction variability. Briefly, following the addition of deuterium-labeled ASP2151 as an internal standard (IS), dog plasma samples or acetonitrile-added urine samples were filtrated. The filtrates were then injected into a column-switching liquid chromatography-tandem mass spectrometry (LC-MS/MS) system and trapped onto an extraction column. Extracts were back-flushed onto an analytical C18 column (4.6×50mm, 3μm) with a mobile phase consisting of methanol, tetrahydrofuran, and 20mmol/L ammonium acetate (45:5:50, v/v/v). The eluent was monitored in the negative atmospheric pressure chemical ionization mode. The calibration curve was linear over a range of 5-1000ng/mL for plasma and 0.5-100μg/mL for urine. Validation data met the acceptance criteria in accordance with regulatory guidance and demonstrated that these methods were selective, accurate, and reproducible. In addition, the present methods were successfully applied to a pharmacokinetic study in dogs. Copyright © 2015 Elsevier B.V. All rights reserved.

  8. Cloud-point extraction is compatible with liquid chromatography coupled to electrospray ionization mass spectrometry for the determination of antazoline in human plasma.

    PubMed

    Giebułtowicz, Joanna; Kojro, Grzegorz; Piotrowski, Roman; Kułakowski, Piotr; Wroczyński, Piotr

    2016-09-05

    Cloud-point extraction (CPE) is attracting increasing interest in a number of analytical fields, including bioanalysis, as it provides a simple, safe and environmentally-friendly sample preparation technique. However, there are only few reports on the application of this extraction technique in liquid chromatography-electrospray ionization-tandem mass spectrometry (LC-ESI-MS/MS) analysis. In this study, CPE was used for the isolation of antazoline from human plasma. To date, only one method of antazoline isolation from plasma exists-liquid-liquid extraction (LLE). The aim of this study was to prove the compatibility of CPE and LC-ESI-MS/MS and the applicability of CPE to the determination of antazoline in spiked human plasma and clinical samples. Antazoline was isolated from human plasma using Triton X-114 as a surfactant. Xylometazoline was used as an internal standard. NaOH concentration, temperature and Triton X-114 concentration were optimized. The absolute matrix effect was carefully investigated. All validation experiments met international acceptance criteria and no significant relative matrix effect was observed. The compatibility of CPE and LC-ESI-MS/MS was confirmed using clinical plasma samples. The determination of antazoline concentration in human plasma in the range 10-2500ngmL(-1) by the CPE method led to results which are equivalent to those obtained by the widely used liquid-liquid extraction method. Copyright © 2016 Elsevier B.V. All rights reserved.

  9. Penicillin Dried Blood Spot Assay for Use in Patients Receiving Intramuscular Benzathine Penicillin G and Other Penicillin Preparations To Prevent Rheumatic Fever.

    PubMed

    Page-Sharp, Madhu; Coward, Jonathan; Moore, Brioni R; Salman, Sam; Marshall, Lewis; Davis, Timothy M E; Batty, Kevin T; Manning, Laurens

    2017-08-01

    Rheumatic heart disease (RHD) remains an important global health challenge. Administration of benzathine penicillin (BPG) every 3 to 4 weeks is recommended as a secondary prophylaxis to prevent recurrent episodes of acute rheumatic fever and subsequent RHD. Following intramuscular injection, BPG is hydrolyzed to penicillin G (benzylpenicillin). However, little is known of the pharmacokinetics (PK) of BPG in pediatric populations at high risk of RHD or of the pharmacokinetic-pharmacodynamic relationship between penicillin exposure and clinically relevant outcomes. Dried blood spot (DBS) assays can facilitate PK studies in situations where frequent venous blood sampling is logistically difficult. A liquid chromatography-mass spectroscopy assay for penicillin G in plasma and DBS was developed and validated. Application of the DBS assay for PK studies was confirmed using samples from adult patients receiving penicillin as part of an infection management plan. The limit of quantification for penicillin G in DBS was 0.005 mg/liter. Penicillin G is stable in DBS for approximately 12 h at room temperature (22°C), 6 days at 4°C, and >1 month at -20°C. Plasma and DBS penicillin G concentrations for patients receiving BPG and penicillin G given via bolus doses correlated well and had comparable time-concentration profiles. There was poor correlation for patients receiving penicillin via continuous infusions, perhaps as a result of the presence of residual penicillin in the peripherally inserted central catheter, from which the plasma samples were collected. The present DBS penicillin G assay can be used as a surrogate for plasma concentrations to provide valid PK data for studies of BPG and other penicillin preparations developed to prevent rheumatic fever and RHD. Copyright © 2017 American Society for Microbiology.

  10. Quantitative determination of fenoterol and fenoterol derivatives in rat plasma using on-line immunoextraction and liquid chromatography/mass spectrometry.

    PubMed

    Kim, Hee Seung; Siluk, Danuta; Wainer, Irving W

    2009-04-17

    An on-line immunoextraction and liquid chromatography/mass spectrometry (LC/MS) method was developed and validated for the determination of R,R'-fenoterol, R,R'-methoxyfenoterol and R,S'-naphthylfenoterol in rat plasma. Sample preparation involved immunoextraction of analytes using an antibody raised against R,R'- and R,S'-aminofenoterol that was immobilized onto chromatographic support. LC was performed on a Waters hydrophilic interaction chromatography (HILIC) column (150 mm x 2.1mm), using an isocratic mobile phase of methanol:ammonium acetate (10mM, pH 6.8) (90:10, v/v) at a flow rate of 0.2 ml/min. The MS was operated in the single ion monitoring mode (m/z 304.2 for R,R'-fenoterol, m/z 318.1 for R,R'-methoxyfenoterol, and m/z 339.2 for R,S'-naphthylfenoterol). Optimization of analytes desorption process from the immunoextraction column was performed by factorial analysis and the sample calibration curves were made with spiked rat plasma samples containing 0.5-100 ng/ml of drugs. The cross-selectivity studies of the antibody were determined and the results suggested high selectivities toward R,R'-fenoterol, R,R'-methoxyfenoterol and R,S'-naphthylfenoterol. The accuracy of assay was more than 96% while intra- and inter-day precision of assay were less than 12.4%. Stability studies (2h benchtop, freeze/thaw, and autosampler stability) were conducted and the analytes were stable through out studies. The validated method was used to determine the plasma concentration-time profiles of drugs after oral administration to rats of R,R'-fenoterol, R,R'-methoxyfenoterol and R,S'-naphthylfenoterol.

  11. Quantitative determination of fenoterol and fenoterol derivatives in rat plasma using on-line immunoextraction and liquid chromatography/mass spectrometry

    PubMed Central

    Kim, Hee Seung; Siluk, Danuta; Wainer, Irving W.

    2008-01-01

    An on-line immunoextraction and liquid chromatography/mass spectrometry (LC/MS) method was developed and validated for the determination of R,R′-fenoterol, R,R′-methoxyfenoterol and R,S′-naphthylfenoterol in rat plasma. Sample preparation involved immunoextraction of analytes using an antibody raised against R,R′- and R,S′-aminofenoterol that was immobilized onto chromatographic support. LC was performed on a Waters hydrophilic interaction chromatography (HILIC) column (150 mm × 2.1 mm), using an isocratic mobile phase of methanol:ammonium acetate (10 mM, pH 6.8) (90:10, v/v) at a flow rate of 0.2 ml/min. The MS was operated in the single ion monitoring mode (m/z 304.2 for R,R′-fenoterol, m/z 318.1 for R,R′-methoxyfenoterol, and m/z 339.2 for R,S′-naphthylfenoterol). Optimization of analytes desorption process from the immunoextraction column was performed by factorial analysis and the sample calibration curves were made with spiked rat plasma samples containing 0.5−100 ng/ml of drugs. The cross-selectivity studies of the antibody were determined and the results suggested high selectivities toward R,R′-fenoterol, R,R′-methoxyfenoterol and R,S′-naphthylfenoterol. The accuracy of assay was more than 96% while intra- and inter-day precision of assay were less than 12.4%. Stability studies (2 h benchtop, freeze/thaw, and autosampler stability) were conducted and the analytes were stable through out studies. The validated method was used to determine the plasma concentration–time profiles of drugs after oral administration to rats of R,R′-fenoterol, R,R′-methoxyfenoterol and R,S′-naphthylfenoterol. PMID:18778830

  12. Penicillin Dried Blood Spot Assay for Use in Patients Receiving Intramuscular Benzathine Penicillin G and Other Penicillin Preparations To Prevent Rheumatic Fever

    PubMed Central

    Page-Sharp, Madhu; Coward, Jonathan; Moore, Brioni R.; Marshall, Lewis; Batty, Kevin T.

    2017-01-01

    ABSTRACT Rheumatic heart disease (RHD) remains an important global health challenge. Administration of benzathine penicillin (BPG) every 3 to 4 weeks is recommended as a secondary prophylaxis to prevent recurrent episodes of acute rheumatic fever and subsequent RHD. Following intramuscular injection, BPG is hydrolyzed to penicillin G (benzylpenicillin). However, little is known of the pharmacokinetics (PK) of BPG in pediatric populations at high risk of RHD or of the pharmacokinetic-pharmacodynamic relationship between penicillin exposure and clinically relevant outcomes. Dried blood spot (DBS) assays can facilitate PK studies in situations where frequent venous blood sampling is logistically difficult. A liquid chromatography-mass spectroscopy assay for penicillin G in plasma and DBS was developed and validated. Application of the DBS assay for PK studies was confirmed using samples from adult patients receiving penicillin as part of an infection management plan. The limit of quantification for penicillin G in DBS was 0.005 mg/liter. Penicillin G is stable in DBS for approximately 12 h at room temperature (22°C), 6 days at 4°C, and >1 month at −20°C. Plasma and DBS penicillin G concentrations for patients receiving BPG and penicillin G given via bolus doses correlated well and had comparable time-concentration profiles. There was poor correlation for patients receiving penicillin via continuous infusions, perhaps as a result of the presence of residual penicillin in the peripherally inserted central catheter, from which the plasma samples were collected. The present DBS penicillin G assay can be used as a surrogate for plasma concentrations to provide valid PK data for studies of BPG and other penicillin preparations developed to prevent rheumatic fever and RHD. PMID:28559267

  13. A rapid, accurate and robust particle-based assay for the simultaneous screening of plasma samples for the presence of five different anti-cytokine autoantibodies.

    PubMed

    Guldager, Daniel Kring Rasmussen; von Stemann, Jakob Hjorth; Larsen, Rune; Bay, Jakob Thaning; Galle, Pia Søndergaard; Svenson, Morten; Ullum, Henrik; Hansen, Morten Bagge

    2015-10-01

    To establish and validate a rapid, cost-effective and accurate screening assay for the simultaneous testing of human naturally occurring anti-cytokine autoantibodies (c-aAb) targeting interleukin-1α (IL-1α), interleukin-6 (IL-6), interleukin-10 (IL-10), granulocyte-macrophage colony-stimulating factor (GM-CSF), and interferon α (IFNα). Because the c-aAbs can be transferred to patients through blood transfusion, the assay was used to assess c-aAb levels in a cohort of patients who were receiving blood transfusions and subsequently presented with or without febrile reactions. The microsphere-based Luminex platform was used. Recombinant forms of human IL-1α, IL-6, IL-10, GM-CSF, and IFNα were gently coupled to MAG-PLEX beads. Plasma IgG binding was measured with phycoerythrin (PE)-labeled secondary antibodies. Previously confirmed c-aAb positive and negative donor plasma samples and pooled normal immunoglobulin preparations were used to validate the assay. Plasma samples from 98 transfusion recipients, half of whom presented with febrile reactions, were tested by the assay. The assay detected specific and saturable immunoglobulin G (IgG) binding to each of the tested cytokines in previously confirmed c-aAb positive plasmas and in preparations of pooled normal immunoglobulin. Confirmed c-aAb negative plasmas gave no saturable binding. The detection limit of the cytokine autoantibodies was estimated to be between 1 pM and 10 pM. The recovery of confirmed cytokine autoantibodies quantities in the negative plasma samples ranged between 80% and 125%. The analytical intra- and inter-assay variations were 4% and 11%, respectively. Varying c-aAb levels were detectable in the transfusion recipients. There was no difference in c-aAb frequency between the patients with or without febrile transfusion reactions. The c-aAb level before and after the blood transfusions varied only slightly and in an irregular manner. This assay simultaneously detected up to five different c-aAbs in pooled human IgG and in plasma from individual blood donors, and it was deemed suitable for larger screenings. Based on confirmed antibody binding characteristics and the resultant reactivity in this multiplex assay, a classification of the c-aAb levels was suggested. The screening results of the recipients who received blood transfusions indicate that more studies are needed to clarify the role of antibodies, if any, in transfusion medicine and in high-dose immunoglobulin treatment. Copyright © 2015 Elsevier B.V. All rights reserved.

  14. Comparison of ESR1 Mutations in Tumor Tissue and Matched Plasma Samples from Metastatic Breast Cancer Patients.

    PubMed

    Takeshita, Takashi; Yamamoto, Yutaka; Yamamoto-Ibusuki, Mutsuko; Tomiguchi, Mai; Sueta, Aiko; Murakami, Keiichi; Omoto, Yoko; Iwase, Hirotaka

    2017-10-01

    ESR1 mutation in circulating cell-free DNA (cfDNA) is emerging as a noninvasive biomarker of acquired resistance to endocrine therapy, but there is a paucity of data comparing the status of ESR1 gene in cfDNA with that in its corresponding tumor tissue. The objective of this study is to validate the degree of concordance of ESR1 mutations between plasma and tumor tissue. ESR1 ligand-binding domain mutations Y537S, Y537N, Y537C, and D538G were analyzed using droplet digital PCR in 35 patients with metastatic breast cancer (MBC) (35 tumor tissue samples and 67 plasma samples). Of the 35 paired samples, 26 (74.3%) were concordant: one patient had detectable ESR1 mutations both plasma (ESR1 Y537S/Y537N) and tumor tissue (ESR1 Y537S/Y537C), and 25 had WT ESR1 alleles in both. Nine (25.7%) had discordance between the plasma and tissue results: five had mutations detected only in their tumor tissue (two Y537S, one Y537C, one D538G, and one Y537S/Y537N/D538G), and four had mutations detected only in their plasma (one Y537S, one Y537N, and two Y537S/Y537N/D538G). Furthermore, longitudinal plasma samples from 19 patients were used to assess changes in the presence of ESR1 mutations during treatment. Eleven patients had cfDNA ESR1 mutations over the course of treatment. A total of eight of 11 patients with MBC with cfDNA ESR1 mutations (72.7%) had the polyclonal mutations. We have shown the independent distribution of ESR1 mutations between plasma and tumor tissue in 35 patients with MBC. Copyright © 2017 The Authors. Published by Elsevier Inc. All rights reserved.

  15. A contaminant-free assessment of Endogenous Retroviral RNA in human plasma

    PubMed Central

    Karamitros, Timokratis; Paraskevis, Dimitrios; Hatzakis, Angelos; Psichogiou, Mina; Elefsiniotis, Ioannis; Hurst, Tara; Geretti, Anna-Maria; Beloukas, Apostolos; Frater, John; Klenerman, Paul; Katzourakis, Aris; Magiorkinis, Gkikas

    2016-01-01

    Endogenous retroviruses (ERVs) comprise 6–8% of the human genome. HERVs are silenced in most normal tissues, up-regulated in stem cells and in placenta but also in cancer and HIV-1 infection. Crucially, there are conflicting reports on detecting HERV RNA in non-cellular clinical samples such as plasma that suggest the study of HERV RNA can be daunting. Indeed, we find that the use of real-time PCR in a quality assured clinical laboratory setting can be sensitive to low-level proviral contamination. We developed a mathematical model for low-level contamination that allowed us to design a laboratory protocol and standard operating procedures for robust measurement of HERV RNA. We focus on one family, HERV-K HML-2 (HK2) that has been most recently active even though they invaded our ancestral genomes almost 30 millions ago. We extensively validated our experimental design on a model cell culture system showing high sensitivity and specificity, totally eliminating the proviral contamination. We then tested 236 plasma samples from patients infected with HIV-1, HCV or HBV and found them to be negative. The study of HERV RNA for human translational studies should be performed with extensively validated protocols and standard operating procedures to control the widespread low-level human DNA contamination. PMID:27640347

  16. A fast and validated method for the determination of malondialdehyde in fish liver using high-performance liquid chromatography with a photodiode array detector.

    PubMed

    Faizan, Mohammad; Esatbeyoglu, Tuba; Bayram, Banu; Rimbach, Gerald

    2014-04-01

    Malondialdehyde (MDA) is a biomarker of lipid peroxidation and is present in foods and biological samples such as plasma. A high-performance liquid chromatography (HPLC) method was applied to determine MDA in fish liver samples after derivatization with 2,4-dinitrophenylhydrazine (DNPH) using a ODS2 column (10 cm × 4.6 mm, 3 μm) and a photodiode array detector. The mobile phase consisted of 0.2% acetic acid (v/v) in distilled water and acetonitrile (42:58, v/v). The present method was validated in terms of linearity, lower limit of quantification, lower limit of detection, precision, accuracy, recovery, and stability of MDA according to U.S. Food and Drug Administration (FDA) guidelines. The limit of quantification of MDA was 0.39 μmol/L, which is comparable to other methods. The recovery of the spiked MDA liver samples was in the range of 92.4% to 104.2%. This newly modified HPLC method is specific, sensitive, and accurate and allows the analysis of MDA within 4 min in fish liver but also in other tissues and plasma. © 2014 Institute of Food Technologists®

  17. The validation of the Z-Scan technique for the determination of plasma glucose

    NASA Astrophysics Data System (ADS)

    Alves, Sarah I.; Silva, Elaine A. O.; Costa, Simone S.; Sonego, Denise R. N.; Hallack, Maira L.; Coppini, Ornela L.; Rowies, Fernanda; Azzalis, Ligia A.; Junqueira, Virginia B. C.; Pereira, Edimar C.; Rocha, Katya C.; Fonseca, Fernando L. A.

    2013-11-01

    Glucose is the main energy source for the human body. The concentration of blood glucose is regulated by several hormones including both antagonists: insulin and glucagon. The quantification of glucose in the blood is used for diagnosing metabolic disorders of carbohydrates, such as diabetes, idiopathic hypoglycemia and pancreatic diseases. Currently, the methodology used for this determination is the enzymatic colorimetric with spectrophotometric. This study aimed to validate the use of measurements of nonlinear optical properties of plasma glucose via the Z-Scan technique. For this we used samples of calibrator patterns that simulate commercial samples of patients (ELITech ©). Besides calibrators, serum glucose levels within acceptable reference values (normal control serum - Brazilian Society of Clinical Pathology and Laboratory Medicine) and also overestimated (pathological control serum - Brazilian Society of Clinical Pathology and Laboratory Medicine) were used in the methodology proposal. Calibrator dilutions were performed and determined by the Z-Scan technique for the preparation of calibration curve. In conclusion, Z-Scan method can be used to determinate glucose levels in biological samples with enzymatic colorimetric reaction and also to apply the same quality control parameters used in biochemistry clinical.

  18. Determination of rivaroxaban in patient's plasma samples by anti-Xa chromogenic test associated to High Performance Liquid Chromatography tandem Mass Spectrometry (HPLC-MS/MS).

    PubMed

    Derogis, Priscilla Bento Matos; Sanches, Livia Rentas; de Aranda, Valdir Fernandes; Colombini, Marjorie Paris; Mangueira, Cristóvão Luis Pitangueira; Katz, Marcelo; Faulhaber, Adriana Caschera Leme; Mendes, Claudio Ernesto Albers; Ferreira, Carlos Eduardo Dos Santos; França, Carolina Nunes; Guerra, João Carlos de Campos

    2017-01-01

    Rivaroxaban is an oral direct factor Xa inhibitor, therapeutically indicated in the treatment of thromboembolic diseases. As other new oral anticoagulants, routine monitoring of rivaroxaban is not necessary, but important in some clinical circumstances. In our study a high-performance liquid chromatography-tandem mass spectrometry (HPLC-MS/MS) method was validated to measure rivaroxaban plasmatic concentration. Our method used a simple sample preparation, protein precipitation, and a fast chromatographic run. It was developed a precise and accurate method, with a linear range from 2 to 500 ng/mL, and a lower limit of quantification of 4 pg on column. The new method was compared to a reference method (anti-factor Xa activity) and both presented a good correlation (r = 0.98, p < 0.001). In addition, we validated hemolytic, icteric or lipemic plasma samples for rivaroxaban measurement by HPLC-MS/MS without interferences. The chromogenic and HPLC-MS/MS methods were highly correlated and should be used as clinical tools for drug monitoring. The method was applied successfully in a group of 49 real-life patients, which allowed an accurate determination of rivaroxaban in peak and trough levels.

  19. Development and validation of a high throughput assay for the quantification of multiple green tea-derived catechins in human plasma.

    PubMed

    Mawson, Deborah H; Jeffrey, Keon L; Teale, Philip; Grace, Philip B

    2018-06-19

    A rapid, accurate and robust method for the determination of catechin (C), epicatechin (EC), gallocatechin (GC), epigallocatechin (EGC), catechin gallate (Cg), epicatechin gallate (ECg), gallocatechin gallate (GCg) and epigallocatechin gallate (EGCg) concentrations in human plasma has been developed. The method utilises protein precipitation following enzyme hydrolysis, with chromatographic separation and detection using reversed-phase liquid chromatography - tandem mass spectrometry (LC-MS/MS). Traditional issues such as lengthy chromatographic run times, sample and extract stability, and lack of suitable internal standards have been addressed. The method has been evaluated using a comprehensive validation procedure, confirming linearity over appropriate concentration ranges, and inter/intra batch precision and accuracies within suitable thresholds (precisions within 13.8% and accuracies within 12.4%). Recoveries of analytes were found to be consistent between different matrix samples, compensated for using suitable internal markers and within the performance of the instrumentation used. Similarly, chromatographic interferences have been corrected using the internal markers selected. Stability of all analytes in matrix is demonstrated over 32 days and throughout extraction conditions. This method is suitable for high throughput sample analysis studies. This article is protected by copyright. All rights reserved.

  20. Determination of a PDE4 inhibitor Hemay005 in human plasma and urine by UPLC-MS/MS and its application to a PK study.

    PubMed

    Liu, Xuemei; Chen, Rui; Zeng, Guanghuai; Gao, Ying; Liu, Xiuping; Zhang, Donglei; Hu, Pei; Wang, Hongyun; Jiang, Ji

    2018-06-04

    Hemay005 is a novel small-molecule inhibitor of phosphodiesterase-4 developed for the treatment of psoriasis. Measurement of Hemay005 in biological samples is critical for evaluation of its pharmacokinetics in clinical studies. Methodology & results: Plasma and urine samples were extracted and then chromatographed on an Acquity UPLC HSS T3 column with a gradient elution. Detection was performed on a Xevo TQ-S tandem mass spectrometer using negative ESI. For the first time, a sensitive and robust ultra-high performance liquid chromatography-tandem mass spectrometry (UPLC-MS/MS) method was established and validated for the quantitative determination of Hemay005 in human plasma and urine, and it was successfully applied to evaluate the pharmacokinetics of Hemay005 in healthy subjects in a first-in-human study.

  1. Quantitative determination of carfilzomib in mouse plasma by liquid chromatography-tandem mass spectrometry and its application to a pharmacokinetic study.

    PubMed

    Min, Jee Sun; Kim, Jiseon; Kim, Jung Ho; Kim, Doyun; Zheng, Yu Fen; Park, Ji Eun; Lee, Wooin; Bae, Soo Kyung

    2017-11-30

    A highly sensitive and rapid LC-MS/MS method was developed and validated to determine the levels of carfilzomib in mice plasma by using chlorpropamide as an internal standard. Carfilzomib and chlorpropamide were extracted from 5 μL of plasma after protein precipitation with acetonitrile. Chromatographic separation was performed on Phenomenex Luna C 18 column (50×2.0mm id, 3μm). The mobile phase consisted of 0.1% formic acid in acetonitrile -0.1% formic acid in water (1:1v/v) and the flow rate was 0.3mL/min. The total chromatographic run time was 2.5min. Detection was performed on a triple quadrupole mass spectrometer equipped with positive-ion electrospray ionization by selected reaction monitoring of the transitions at m/z 720.20>100.15 (for carfilzomib) and m/z 277.05>111.05 (for the internal standard). The lower limit of quantification was 0.075ng/mL and the linear range was 0.075-1250ng/mL (r≥0.9974). All validation data, including selectivity, precision, accuracy, matrix effect, recovery, dilution integrity, stability, and incurred sample reanalysis, were well within acceptance limits. This newly developed bioanalytical method was simple, highly sensitive, required only a small volume of plasma, and was suitable for application in pharmacokinetic studies in mice that used serial blood sampling. Copyright © 2017 Elsevier B.V. All rights reserved.

  2. High-Resolution Inductively Coupled Plasma Optical Emission Spectrometry for (234)U/(238)Pu Age Dating of Plutonium Materials and Comparison to Sector Field Inductively Coupled Plasma Mass Spectrometry.

    PubMed

    Krachler, Michael; Alvarez-Sarandes, Rafael; Rasmussen, Gert

    2016-09-06

    Employing a commercial high-resolution inductively coupled plasma optical emission spectrometry (HR-ICP-OES) instrument, an innovative analytical procedure for the accurate determination of the production age of various Pu materials (Pu powder, cardiac pacemaker battery, (242)Cm heat source, etc.) was developed and validated. This undertaking was based on the fact that the α decay of (238)Pu present in the investigated samples produced (234)U and both mother and daughter could be identified unequivocally using HR-ICP-OES. Benefiting from the high spectral resolution of the instrument (<5 pm) and the isotope shift of the emission lines of both nuclides, (234)U and (238)Pu were selectively and directly determined in the dissolved samples, i.e., without a chemical separation of the two analytes from each other. Exact emission wavelengths as well as emission spectra of (234)U centered around λ = 411.590 nm and λ = 424.408 nm are reported here for the first time. Emission spectra of the isotopic standard reference material IRMM-199, comprising about one-third each of (233)U, (235)U, and (238)U, confirmed the presence of (234)U in the investigated samples. For the assessment of the (234)U/(238)Pu amount ratio, the emission signals of (234)U and (238)Pu were quantified at λ = 424.408 nm and λ = 402.148 nm, respectively. The age of the investigated samples (range: 26.7-44.4 years) was subsequently calculated using the (234)U/(238)Pu chronometer. HR-ICP-OES results were crossed-validated through sector field inductively coupled plasma mass spectrometry (SF-ICPMS) analysis of the (234)U/(238)Pu amount ratio of all samples applying isotope dilution combined with chromatographic separation of U and Pu. Available information on the assumed ages of the analyzed samples was consistent with the ages obtained via the HR-ICP-OES approach. Being based on a different physical detection principle, HR-ICP-OES provides an alternative strategy to the well-established mass spectrometric approach and thus effectively adds to the quality assurance of (234)U/(238)Pu age dates.

  3. A simple assay for the simultaneous determination of human plasma albendazole and albendazole sulfoxide levels by high performance liquid chromatography in tandem mass spectrometry with solid-phase extraction.

    PubMed

    Wojnicz, Aneta; Cabaleiro-Ocampo, Teresa; Román-Martínez, Manuel; Ochoa-Mazarro, Dolores; Abad-Santos, Francisco; Ruiz-Nuño, Ana

    2013-11-15

    A simple, reproducible and fast (4 min chromatogram) method of liquid chromatography in tandem with mass spectrometry (LC/MS-MS) was developed to determine simultaneously the plasma levels of albendazole (ABZ) and its metabolite albendazole sulfoxide (ABZOX) for pharmacokinetic and clinical analysis. Each plasma sample was extracted by solid phase extraction (SPE) using phenacetin as internal standard (IS). The extracted sample was eluted with a Zorbax XDB-CN column using an isocratic method. The mobile phase consisting of water with 1% acetic acid (40%, A) and MeOH (60%, B), was used at a flow rate of 1 mL/min. ABZ and ABZOX were detected and identified by mass spectrometry with electrospray ionization (ESI) in the positive ion and multiple-reaction monitoring (MRM) mode. The method was linear in the range of 5-1000 ng/mL for ABZ and 10-1500 ng/mL (full validation) or 10-5000 ng/mL (partial validation) for ABZOX, with 5 and 10 ng/mL lower limit of quantification (LLOQ) for ABZ and ABZOX, respectively. The tests of accuracy and precision, matrix effect, extraction recovery and stability of the samples for both ABZ and ABZOX did not deviate more than 20% for the LLOQ and no more than 15% for other quality controls (QCs), according to regulatory agencies. © 2013.

  4. Improving the sensitivity and specificity of a bioanalytical assay for the measurement of certolizumab pegol.

    PubMed

    Smeraglia, John; Silva, John-Paul; Jones, Kieran

    2017-08-01

    In order to evaluate placental transfer of certolizumab pegol (CZP), a more sensitive and selective bioanalytical assay was required to accurately measure low CZP concentrations in infant and umbilical cord blood. Results & methodology: A new electrochemiluminescence immunoassay was developed to measure CZP levels in human plasma. Validation experiments demonstrated improved selectivity (no matrix interference observed) and a detection range of 0.032-5.0 μg/ml. Accuracy and precision met acceptance criteria (mean total error ≤20.8%). Dilution linearity and sample stability were acceptable and sufficient to support the method. The electrochemiluminescence immunoassay was validated for measuring low CZP concentrations in human plasma. The method demonstrated a more than tenfold increase in sensitivity compared with previous assays, and improved selectivity for intact CZP.

  5. A Population Pharmacokinetic Model for Disposition in Plasma, Saliva and Urine of Scopolamine after Intranasal Administration to Healthy Human Subjects

    NASA Technical Reports Server (NTRS)

    Wu, L.; Tam, V. H.; Chow, D. S. L.; Putcha, L.

    2014-01-01

    An intranasal gel formulation of scopolamine (INSCOP) was developed for the treatment of Space Motion Sickness. The bioavailability and pharmacokinetics (PK) were evaluated under the Food and Drug Administration guidelines for clinical trials with an Investigative New Drug (IND) protocol. The aim of this project was to develop a PK model that can predict the relationship between plasma, saliva and urinary scopolamine concentrations using data collected from the IND clinical trials with INSCOP. Methods: Twelve healthy human subjects were administered three dose levels (0.1, 0.2 and 0.4 mg) of INSCOP. Serial blood, saliva and urine samples were collected between 5 min and 24 h after dosing and scopolamine concentrations were measured by using a validated LC-MS-MS assay. Pharmacokinetic Compartmental models, using actual dosing and sampling times, were built using Phoenix (version 1.2). Model selection was based on the likelihood ratio test on the difference of criteria (-2LL) and comparison of the quality of fit plots. Results: The best structural model for INSCOP (minimal -2LL= 502.8) was established. It consisted of one compartment each for plasma, saliva and urine, respectively, which were connected with linear transport processes except the nonlinear PK process from plasma to saliva compartment. The best-fit estimates of PK parameters from individual PK compartmental analysis and Population PK model analysis were shown in Tables 1 and 2, respectively. Conclusion: A population PK model that could predict population and individual PK of scopolamine in plasma, saliva and urine after dosing was developed and validated. Incorporating a non-linear transfer from plasma to saliva compartments resulted in a significantly improved model fitting. The model could be used to predict scopolamine plasma concentrations from salivary and urinary drug levels, allowing non-invasive therapeutic monitoring of scopolamine in space and other remote environments.

  6. Enantioselective quantitation of the ecstasy compound (R)- and (S)-N-ethyl-3,4-methylenedioxyamphetamine and its major metabolites in human plasma and urine.

    PubMed

    Buechler, Jochen; Schwab, Matthias; Mikus, Gerd; Fischer, Beate; Hermle, Leo; Marx, Claudia; Grön, Georg; Spitzer, Manfred; Kovar, Karl Artur

    2003-08-15

    An enantioselective HPLC method has been developed and validated for the stereospecific analysis of N-ethyl-3,4-methylenedioxyamphetamine (MDE) and its major metabolites N-ethyl-4-hydroxy-3-methoxyamphetamine (HME) and 3,4-methylenedioxyamphetamine (MDA). These compounds have been analyzed both from human plasma and urine after administration of 70 mg pure MDE-hydrochloride enantiomers to four subjects. The samples were prepared by hydrolysis of the o-glucuronate and sulfate conjugates using beta-glucuronidase/arylsulfatase and solid-phase extraction with a cation-exchange phase. A chiral stationary protein phase (chiral-CBH) was used for the stereoselective determination of MDE, HME and MDA in a single HPLC run using sodium dihydrogenphosphate, ethylendiaminetetraacetic acid disodium salt and isopropanol as the mobile phase (pH 6.44) and fluorimetric detection (lambda(ex) 286 nm, lambda(em) 322 nm). Moreover, a suitable internal standard (N-ethyl-3,4-methylenedioxybenzylamine) was synthesized and qualified for quantitation purposes. The method showed high recovery rates (>95%) and limits of quantitation for MDE and MDA of 5 ng/ml and for HME of 10 ng/ml. The RSDs for all working ranges of MDE, MDA and HME in plasma and urine, respectively, were less than 1.5%. After validation of the analytical methods in plasma and urine samples pharmacokinetic parameters were calculated. The plasma concentrations of (R)-MDE exceeded those of the S-enantiomer (ratio R:S of the area under the curve, 3.1) and the plasma half time of (R)-MDE was longer than that of (S)-MDE (7.9 vs. 4.0 h). In contrast, the stereochemical disposition of the MDE metabolites HME and MDA was reversed. Concentrations of the (S)-metabolites in plasma of volunteers were much higher than those of the (R)-enantiomers.

  7. Validation of an HPLC method for the determination of urinary and plasma levels of N1-methylnicotinamide, an endogenous marker of renal cationic transport and plasma flow.

    PubMed

    Musfeld, C; Biollaz, J; Bélaz, N; Kesselring, U W; Decosterd, L A

    2001-01-01

    N1-Methylnicotinamide (NMN) is an endogenous cationic metabolite of nicotinamide (niacine, vitamine PP) whose renal clearance reflects both the capacity of the renal tubular transport system to secrete organic cations and renal plasma flow. NMN is present in human plasma and urine at the 1-117-ng ml(-1) and 0.5-25-microg ml(-1) concentration range, respectively, and its level depends notably on pathophysiological (age, renal or hepatic diseases) conditions. We report the optimization and validation of an HPLC method for the measurement of endogenous NMN in biological fluids after derivatization into a fluorescent compound. Plasma is first deproteinized with TCA 20% and the urine diluted 1:10 with HCI 10(-4) M prior to the derivatization procedure, which includes a condensation reaction of NMN with acetophenone in NaOH at 0 degrees C, followed by dehydration in formic acid and subsequent formation of the fluorescent 1,6-naphthyridine derivatives after heating samples in a boiling water bath. The synthetic homologous derivative N1-ethylnicotinamide (NEN) reacts similarly and is added as internal standard into the biological fluid. The reaction mixture is subjected to reverse phase high performance liquid chromatography on a Nucleosil 100-C18 column using a mobile phase (acetonitrile 22%, triethylamine 0.5%, 0.01 M sodium heptanesulfonate adjusted to pH 3.2), delivered isocratically at a flow rate of 1 ml min(-1), NMN and NEN are detected at 7.8 and 10 min by spectrofluorimetry with excitation and emission wavelengths set at 366 and 418 nm, respectively. The addition-calibration method is used with plasma and urine pools. Calibration curves (using the internal standard method) are linear (r2 > 0.997) at concentrations up to 109 ng ml(-1) and 15.7 microg ml(-1) in plasma and urine, respectively. Both intra- and inter-assay precision of plasma control samples at 10, 50 and 90 ng ml(-1) were lower than 3.3% and concentrations not deviating more than 2.7% from their nominal values. In urine intra- and inter-assay CVs of control samples at 1, 5 and 9 microg ml(-1) are lower than 8.3%, with concentrations not deviating more than -9.0 to +11.8% from their nominal values. This analytical method has therefore the required sensitivity and selectivity to measure NMN in plasma and urine, enabling the non-invasive determination of the tubular secretory capacity of the kidney and the renal plasma flow.

  8. Development and validation of an HPLC method for the determination of dibenzoylmethane in rat plasma and its application to the pharmacokinetic study.

    PubMed

    Shen, Guoxiang; Hong, Jin-Liern; Kong, Ah-Ng Tony

    2007-06-01

    A highly sensitive and simple high-performance liquid chromatographic (HPLC) assay has been developed and validated for the quantification of dibenzoylmethane (DBM) in rat plasma. DBM and internal standard (I.S.) 1-(5-chloro-2-hydroxy-4-methylphenyl)-3-phenyl-1,3-propanedione (CHMPP) were extracted from rat plasma by ethyl acetate/methanol (95:5, v/v) and analyzed using reverse-phase gradient elution with a Phenomenex Gemini C18 5-mum column. A gradient of mobile phase (mobile phase A: water/methanol (80:20, v/v) with 0.1% TFA and mobile phase B: acetonitrile with 0.1% TFA) at a flow rate of 0.2 mL/min, and ultraviolet (UV) detection at 335 nm were utilized. The lower limit of quantification (LLOQ) using 50 microL rat plasma was 0.05 microg/mL. The calibration curve was linear over a concentration range of 0.05-20 microg/mL. The mean recoveries were 80.6+/-5.7, 83.4+/-1.6 and 77.1+/-3.4% with quality control (QC) level of 0.05, 1 and 20 microg/mL, respectively. Intra- and inter-day assay accuracy and precision fulfilled US FDA guidance for industry bioanalytical method validation. Stability studies showed that DBM was stable in rat plasma after 4h incubation at room temperature, one month storage at -80 degrees C and three freeze/thaw cycles, as well as in reconstitute buffer for 48 h at 4 degrees C. The utility of the assay was confirmed by the successful analysis of plasma samples from DBM pharmacokinetics studies in the rats after oral and intravenous administrations.

  9. Analytical validation of BRAF mutation testing from circulating free DNA using the amplification refractory mutation testing system.

    PubMed

    Aung, Kyaw L; Donald, Emma; Ellison, Gillian; Bujac, Sarah; Fletcher, Lynn; Cantarini, Mireille; Brady, Ged; Orr, Maria; Clack, Glen; Ranson, Malcolm; Dive, Caroline; Hughes, Andrew

    2014-05-01

    BRAF mutation testing from circulating free DNA (cfDNA) using the amplification refractory mutation testing system (ARMS) holds potential as a surrogate for tumor mutation testing. Robust assay validation is needed to establish the optimal clinical matrix for measurement and cfDNA-specific mutation calling criteria. Plasma- and serum-derived cfDNA samples from 221 advanced melanoma patients were analyzed for BRAF c.1799T>A (p.V600E) mutation using ARMS in two stages in a blinded fashion. cfDNA-specific mutation calling criteria were defined in stage 1 and validated in stage 2. cfDNA concentrations in serum and plasma, and the sensitivities and specificities of BRAF mutation detection in these two clinical matrices were compared. Sensitivity of BRAF c.1799T>A (p.V600E) mutation detection in cfDNA was increased by using mutation calling criteria optimized for cfDNA (these criteria were adjusted from those used for archival tumor biopsies) without compromising specificity. Sensitivity of BRAF mutation detection in serum was 44% (95% CI, 35% to 53%) and in plasma 52% (95% CI, 43% to 61%). Specificity was 96% (95% CI, 90% to 99%) in both matrices. Serum contains significantly higher total cfDNA than plasma, whereas the proportion of tumor-derived mutant DNA was significantly higher in plasma. Using mutation calling criteria optimized for cfDNA improves sensitivity of BRAF c.1799T>A (p.V600E) mutation detection. The proportion of tumor-derived cfDNA in plasma was significantly higher than in serum. Copyright © 2014 American Society for Investigative Pathology and the Association for Molecular Pathology. Published by Elsevier Inc. All rights reserved.

  10. Rapid LC-MRM-MS assay for simultaneous quantification of choline, betaine, trimethylamine, trimethylamine N-oxide, and creatinine in human plasma and urine.

    PubMed

    Zhao, Xueqing; Zeisel, Steven H; Zhang, Shucha

    2015-06-17

    There is a growing interest in analyzing choline, betaine, and their gut microbial metabolites including trimethylamine (TMA) and trimethylamine N-oxide (TMAO) in body fluids due to the high relevance of these compounds for human health and diseases. A stable isotope dilution (SID)-LC-MRM-MS assay was developed for the simultaneous determination of choline, betaine, TMA, TMAO, and creatinine in human plasma and urine. The assay was validated using quality control (QC) plasma samples, spiked at low, medium, and high levels. Freeze-thaw stability was also evaluated. The utility of this assay for urine was demonstrated using a nutritional clinical study on the effect of various egg doses on TMAO production in humans. This assay has a wide dynamic range (R 2 > 0.994) for all the analytes (choline: 0.122-250 μM; betaine: 0.488-1000 μM; TMA: 0.244-250 μM; TMAO: 0.061-62.5 μM; and creatinine: 0.977-2000 μM). High intra- and inter-day precision (CV < 6%) and high accuracy (< 15% error) were observed from the QC plasma samples. The assay is reliable for samples undergoing multiple freeze-thaw cycles (tested up to eight cycles). The assay also works for urine samples as demonstrated by a clinical study in which we observed a significant, positive linear response to various egg doses for urinary concentrations of all the analytes except creatinine. A rapid SID-LC-MRM-MS assay for simultaneous quantification of choline, betaine, TMA, TMAO, and creatinine has been developed and validated, and is expected to find wide application in nutrition and cardiovascular studies as well as diagnosis and management of trimethylaminuria. © 2015 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  11. UPLC-MS/MS assay of riluzole in human plasma and cerebrospinal fluid (CSF): Application in samples from spinal cord injured patients.

    PubMed

    Sarkar, Mahua; Grossman, Robert G; Toups, Elizabeth G; Chow, Diana S-L

    2017-11-30

    In the present study, a sensitive and robust LC-MS/MS method has been developed and validated for the quantification of riluzole in human plasma and cerebrospinal fluid (CSF) in clinical samples from patients with spinal cord injury (SCI). Riluzole and its labeled internal standard (IS) were isolated from plasma and CSF by liquid-liquid extraction using ethyl acetate. Riluzole (m/z 235→166) and IS (m/z 238→169) were detected by electrospray ionization (ESI) using multiple reaction monitoring (MRM) in a positive mode. The assay was linear in the concentration range of 0.5 (LLOQ, signal/noise ratio>10)-800ng/ml in plasma, and 1.0 (LLOQ)-800ng/ml in CSF samples. The intra- and inter-day accuracy in plasma were 94.2-110.0% and 97.8-102.0%, respectively, and those in CSF were 87.6-105.1% and 91.9-98.8%, respectively. The intra- and inter-day precision were 2.2-7.2% and 4.0-9.1%, respectively, in plasma, and 1.4-14.1% and 2.6-11.5%, respectively in CSF. Matrix effect was negligible from both matrices with signal percentages of 97.6-100.6% in plasma and 99.4-106.4% in CSF. The recoveries were >75% in plasma, >84% in CSF with low protein (53.9mg/dl), and >68% in CSF with high protein (348.2mg/dl). This method was successfully applied to quantify riluzole concentrations in plasma and CSF from patients with SCI. Copyright © 2017 Elsevier B.V. All rights reserved.

  12. The materials irradiation experiment for testing plasma facing materials at fusion relevant conditions

    DOE PAGES

    Garrison, L. M.; Zenobia, Samuel J.; Egle, Brian J.; ...

    2016-08-01

    The Materials Irradiation Experiment (MITE-E) was constructed at the University of Wisconsin-Madison Inertial Electrostatic Confinement Laboratory to test materials for potential use as plasma-facing materials (PFMs) in fusion reactors. PFMs in fusion reactors will be bombarded with x-rays, neutrons, and ions of hydrogen and helium. More needs to be understood about the interactions between the plasma and the materials to validate their use for fusion reactors. The MITE-E simulates some of the fusion reactor conditions by holding samples at temperatures up to 1000°C while irradiating them with helium or deuterium ions with energies from 10 to 150 keV. The ionmore » gun can irradiate the samples with ion currents of 20 μA–500 μA; the typical current used is 72 μA, which is an average flux of 9 × 10 14 ions/(cm 2 s). The ion gun uses electrostatic lenses to extract and shape the ion beam. A variable power (1-20 W), steady-state, Nd:YAG laser provides additional heating to maintain a constant sample temperature during irradiations. The ion beam current reaching the sample is directly measured and monitored in real-time during irradiations. The ion beam profile has been investigated using a copper sample sputtering experiment. In conclusion, the MITE-E has successfully been used to irradiate polycrystalline and single crystal tungsten samples with helium ions and will continue to be a source of important data for plasma interactions with materials.« less

  13. The materials irradiation experiment for testing plasma facing materials at fusion relevant conditions.

    PubMed

    Garrison, L M; Zenobia, S J; Egle, B J; Kulcinski, G L; Santarius, J F

    2016-08-01

    The Materials Irradiation Experiment (MITE-E) was constructed at the University of Wisconsin-Madison Inertial Electrostatic Confinement Laboratory to test materials for potential use as plasma-facing materials (PFMs) in fusion reactors. PFMs in fusion reactors will be bombarded with x-rays, neutrons, and ions of hydrogen and helium. More needs to be understood about the interactions between the plasma and the materials to validate their use for fusion reactors. The MITE-E simulates some of the fusion reactor conditions by holding samples at temperatures up to 1000 °C while irradiating them with helium or deuterium ions with energies from 10 to 150 keV. The ion gun can irradiate the samples with ion currents of 20 μA-500 μA; the typical current used is 72 μA, which is an average flux of 9 × 10(14) ions/(cm(2) s). The ion gun uses electrostatic lenses to extract and shape the ion beam. A variable power (1-20 W), steady-state, Nd:YAG laser provides additional heating to maintain a constant sample temperature during irradiations. The ion beam current reaching the sample is directly measured and monitored in real-time during irradiations. The ion beam profile has been investigated using a copper sample sputtering experiment. The MITE-E has successfully been used to irradiate polycrystalline and single crystal tungsten samples with helium ions and will continue to be a source of important data for plasma interactions with materials.

  14. The materials irradiation experiment for testing plasma facing materials at fusion relevant conditions

    NASA Astrophysics Data System (ADS)

    Garrison, L. M.; Zenobia, S. J.; Egle, B. J.; Kulcinski, G. L.; Santarius, J. F.

    2016-08-01

    The Materials Irradiation Experiment (MITE-E) was constructed at the University of Wisconsin-Madison Inertial Electrostatic Confinement Laboratory to test materials for potential use as plasma-facing materials (PFMs) in fusion reactors. PFMs in fusion reactors will be bombarded with x-rays, neutrons, and ions of hydrogen and helium. More needs to be understood about the interactions between the plasma and the materials to validate their use for fusion reactors. The MITE-E simulates some of the fusion reactor conditions by holding samples at temperatures up to 1000 °C while irradiating them with helium or deuterium ions with energies from 10 to 150 keV. The ion gun can irradiate the samples with ion currents of 20 μA-500 μA; the typical current used is 72 μA, which is an average flux of 9 × 1014 ions/(cm2 s). The ion gun uses electrostatic lenses to extract and shape the ion beam. A variable power (1-20 W), steady-state, Nd:YAG laser provides additional heating to maintain a constant sample temperature during irradiations. The ion beam current reaching the sample is directly measured and monitored in real-time during irradiations. The ion beam profile has been investigated using a copper sample sputtering experiment. The MITE-E has successfully been used to irradiate polycrystalline and single crystal tungsten samples with helium ions and will continue to be a source of important data for plasma interactions with materials.

  15. Determination of tigecycline in turkey plasma by LC-MS/MS: validation and application in a pharmacokinetic study.

    PubMed

    Jasiecka-Mikołajczyk, A; Jaroszewski, J J

    2017-03-01

    Tigecycline (TIG), a novel glycylcycline antibiotic, plays an important role in the management of complicated skin and intra-abdominal infections. The available data lack any description of a method for determination of TIG in avian plasma. In our study, a selective, accurate and reversed-phase high performance liquid chromatography-tandem mass spectrometry method was developed for the determination of TIG in turkey plasma. Sample preparation was based on protein precipitation and liquid-liquid extraction using 1,2-dichloroethane. Chromatographic separation of TIG and minocycline (internal standard, IS) was achieved on an Atlantis T3 column (150 mm × 3.0 mm, 3.0 μm) using gradient elution. The selected reaction monitoring transitions were performed at 293.60 m/z → 257.10 m/z for TIG and 458.00 m/z → 441.20 m/z for IS. The developed method was validated in terms of specificity, selectivity, linearity, lowest limit of quantification, limit of detection, precision, accuracy, matrix effect, carry-over effect, extraction recovery and stability. All parameters of the method submitted to validation met the acceptance criteria. The assay was linear over the concentration range of 0.01-100 μg/ml. This validated method was successfully applied to a TIG pharmacokinetic study in turkey after intravenous and oral administration at a dose of 10 mg/kg at various time-points.

  16. Development and validation of an LC-MS/MS method to quantify lysergic acid diethylamide (LSD), iso-LSD, 2-oxo-3-hydroxy-LSD, and nor-LSD and identify novel metabolites in plasma samples in a controlled clinical trial.

    PubMed

    Dolder, Patrick C; Liechti, Matthias E; Rentsch, Katharina M

    2018-02-01

    Lysergic acid diethylamide (LSD) is a widely used recreational drug. The aim of this study was to develop and validate a liquid chromatography tandem mass spectrometry (LC-MS/MS) method for the quantification of LSD, iso-LSD, 2-oxo-3-hydroxy LSD (O-H-LSD), and nor-LSD in plasma samples from 24 healthy subjects after controlled administration of 100 μg LSD in a clinical trial. In addition, metabolites that have been recently described in in vitro studies, including lysergic acid monoethylamide (LAE), lysergic acid ethyl-2-hydroxyethylamide (LEO), 2-oxo-LSD, trioxylated-LSD, and 13/14-hydroxy-LSD, should be identified. Separation of LSD and its metabolites was achieved on a reversed phase chromatography column after turbulent-flow online extraction. For the identification and quantification, a triple-stage quadrupole LC-MS/MS instrument was used. The validation data showed slight matrix effects for LSD, iso-LSD, O-H-LSD, or nor-LSD. Mean intraday and interday accuracy and precision were 105%/4.81% and 105%/4.35% for LSD, 98.7%/5.75% and 99.4%/7.21% for iso-LSD, 106%/4.54% and 99.4%/7.21% for O-H-LSD, and 107%/5.82% and 102%/5.88% for nor-LSD, respectively. The limit of quantification was 0.05 ng/mL for LSD, iso-LSD, and nor-LSD and 0.1 ng/mL for O-H-LSD. The limit of detection was 0.01 ng/mL for all compounds. The method described herein was accurate, precise, and the calibration range within the range of expected plasma concentrations. LSD was quantified in the plasma samples of the 24 subjects of the clinical trial, whereas iso-LSD, O-H-LSD, nor-LSD, LAE, LEO, 13/14-hydroxy-LSD, and 2-oxo-LSD could only sporadically be detected but were too low for quantification. © 2017 Wiley Periodicals, Inc.

  17. A fully validated method for the determination of lacosamide in human plasma using gas chromatography with mass spectrometry: application for therapeutic drug monitoring.

    PubMed

    Nikolaou, Panagiota; Papoutsis, Ioannis; Spiliopoulou, Chara; Voudris, Constantinos; Athanaselis, Sotiris

    2015-01-01

    A simple gas chromatographic method with mass spectrometry detection was developed and validated for the determination of lacosamide in human plasma. Lacosamide and the internal standard, levetiracetam-d6, were extracted from 200 μL plasma, by a solid-phase extraction through HF Bond Elut C18 columns, and derivatized using N-methyl-N-tert-butyldimethylsilyltrifluoroacetamide with 1% tert-butyldimethylsilylchloride in acetonitrile. The limit of quantification was found to be 0.20 μg/mL and the assay was linear up to 20.0 μg/mL with correlation coefficient ≥0.994. The intra- and interday precision values were <4.1% in terms of relative standard deviation (%) and the values of intra- and interday accuracy were found to be within -7.2 and 5.3% in terms of relative error (%). Absolute recovery of the method for lacosamide was determined at three concentration levels and ranged from 92.5 to 97.6%. The developed method uses small volumes of plasma and proved to be simple, rapid, and sensitive for the determination of lacosamide in plasma. This method can be used in routine every day analysis of plasma samples obtained from patients who follow respective antiepileptic treatment and for the investigation of clinical and forensic cases where lacosamide is involved. © 2014 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  18. Vitamins D and A can be successfully measured by LC-MS/MS in cord blood diluted plasma.

    PubMed

    Albarhani, Ali A; Collier, Fiona; Greaves, Ronda F; Ponsonby, Anne-Louise; Allen, Katrina J; Vuillermin, Peter J; Roche, Peter; Clarke, Michael W

    2015-11-01

    In widely used protocols for the collection and isolation of cord blood mononuclear cells, investigators are left with substantial volumes of diluted plasma which could be used for other measurements. The aim of this study was to ascertain the validity of umbilical cord blood (UCB) diluted plasma samples for vitamin D, A and E analysis compared to UCB serum samples. Twenty UCB matched samples of diluted plasma and serum were collected. The samples were analysed by two liquid chromatography-tandem mass spectrometry (LC-MS/MS) methods on two separate occasions. The results of 25(OH)D3 obtained by the two laboratories demonstrated close agreement with a mean difference of 0.14nmol/L [95% confidence interval (95% CI), -6.8 to 7.1]. Both methods demonstrate close agreement for 25(OH)D3 in UCB serum versus diluted UCB plasma; mean difference 2.2nmol/L [95% CI, -9.5 to 13.9] and 4.1nmol/L [95% CI, -14.5 to 6.1] for the results from Lab A and Lab B, respectively. Vitamin A was quantified by Lab A in UCB serum and diluted UCB plasma; mean difference 0.07μmol/L [95% CI, -0.41 to 0.28]. Results of 25(OH)D3 epimer and vitamin E in the diluted UCB plasma were below the limit of quantification, and could not be compared with UCB serum. Diluted UCB plasma can be used for the quantification of retinol and 25(OH)D3 by LC-MS/MS. By contrast, quantification of 25(OH)D3 epimer and vitamin E in diluted UCB plasma is not supported by this study due to limitations in analytical sensitivity. Copyright © 2015 The Canadian Society of Clinical Chemists. Published by Elsevier Inc. All rights reserved.

  19. Standard Specimen Reference Set: Lung — EDRN Public Portal

    Cancer.gov

    The NCI/EDRN/SPORE Lung Cancer Biomarkers Group (LCBG) began its activities back in November 2004 and developed clear objectives and strategies on how to begin validating a series of candidate biomarkers for the early detection of lung cancer. The initial goal of the LCBG is to develop the requisite sample resources to validate serum/plasma biomarkers for the early diagnosis of lung cancer. Researchers may use these resources and process for continued biomarker refinement but this is not the primary activity of the LCBG.

  20. Quantification of plasma myo-inositol using gas chromatography-mass spectrometry.

    PubMed

    Guo, Jin; Shi, Yingfei; Xu, Chengbao; Zhong, Rugang; Zhang, Feng; Zhang, Ting; Niu, Bo; Wang, Jianhua

    2016-09-01

    Myo-inositol (MI) deficiency is associated with an increased risk for neural tube defects (NTDs), mental disorders and metabolic diseases. We developed a gas chromatography-mass spectrometry (GC-MS) method to detect MI in human plasma, which was accurate, relatively efficient and convenient for clinical application. An external standard method was used for determination of plasma MI. Samples were analyzed by GC-MS after derivatization. The stable-isotope labeled internal standard approach was used to validate the method's accuracy. Alpha fetal protein (AFP) was detected by chemiluminescence immunoassay. The method was validated by determining the linearity, sensitivity and recovery rate. There was a good agreement between the internal standard approach and the present method. The NTD-affected pregnancies showed lower plasma MI (P=0.024) and higher AFP levels (P=0.001) than control. Maternal MI level showed a better discrimination in spina bifida subgroup, while AFP level showed a better discrimination in anencephaly subgroup after stratification analysis. We developed a sensitive and reliable method for the detection of clinical plasma MI, which might be a marker for NTDs screening, and established fundamental knowledge for clinical diagnosis and prevention for the diseases related to disturbed MI metabolism. Copyright © 2016 Elsevier B.V. All rights reserved.

  1. Myocardial Injury Is Distinguished from Stable Angina by a Set of Candidate Plasma Biomarkers Identified Using iTRAQ/MRM-Based Approach.

    PubMed

    Cheow, Esther Sok Hwee; Cheng, Woo Chin; Yap, Terence; Dutta, Bamaprasad; Lee, Chuen Neng; Kleijn, Dominique P V de; Sorokin, Vitaly; Sze, Siu Kwan

    2018-01-05

    The lack of precise biomarkers that identify patients at risk for myocardial injury and stable angina delays administration of optimal therapy. Hence, the search for noninvasive biomarkers that could accurately stratify patients with impending heart attack, from patients with stable coronary artery disease (CAD), is urgently needed in the clinic. Herein, we performed comparative quantitative proteomics on whole plasma sampled from patients with stable angina (NMI), acute myocardial infarction (MI), and healthy control subjects (Ctrl). We detected a total of 371 proteins with high confidence (FDR < 1%, p < 0.05) including 53 preliminary biomarkers that displayed ≥2-fold modulated expression in patients with CAD (27 associated with atherosclerotic stable angina, 26 with myocardial injury). In the verification phase, we used label-free LC-MRM-MS-based targeted method to verify the preliminary biomarkers in pooled plasma, excluded peptides that were poorly distinguished from background, and performed further validation of the remaining candidates in 49 individual plasma samples. Using this approach, we identified a final panel of eight novel candidate biomarkers that were significantly modulated in CAD (p < 0.05) including proteins associated with atherosclerotic stable angina that were implicated in endothelial dysfunction (F10 and MST1), proteins associated with myocardial injury reportedly involved in plaque destabilization (SERPINA3, CPN2, LUM), and in tissue protection/repair mechanisms (ORM2, ACTG1, NAGLU). Taken together, our data showed that candidate biomarkers with potential diagnostic values can be successfully detected in nondepleted human plasma using an iTRAQ/MRM-based discovery-validation approach and demonstrated the plausible clinical utility of the proposed panel in discriminating atherosclerotic stable angina from myocardial injury in the studied cohort.

  2. Development and validation of an LC-MS/MS analysis for simultaneous determination of delphinidin-3-glucoside, cyanidin-3-glucoside and cyanidin-3-(6-malonylglucoside) in human plasma and urine after blood orange juice administration.

    PubMed

    Giordano, Lucia; Coletta, Walter; Rapisarda, Paolo; Donati, Maria Benedetta; Rotilio, Domenico

    2007-12-01

    Blood orange juice has a high content in anthocyanins, especially represented by delphinidin-3-glucoside (D3G), cyanidin-3-glucoside (C3G) and cyanidin-3-(6-malonylglucoside) (CMG). An LC-MS/MS method for the simultaneous determination of D3G and C3G in human plasma and urine was developed and validated. After sample preparation by SPE, chromatographic separation was performed with an RP-C(18) column, using a water/methanol linear gradient. The quantitation of target compounds was determined by multiple reaction monitoring (MRM) mode, using ESI. The method showed good selectivity, sensitivity (LOD = 0.05 and 0.10 ng/mL for C3G in plasma and urine, respectively; LOD = 0.10 ng/mL for D3G in plasma and urine), linearity (0.20-200 ng/mL; r >or= 0.998), intra- and interday precision and accuracy (

  3. Salting-out assisted liquid-liquid extraction coupled with hydrophilic interaction chromatography for the determination of biguanides in biological and environmental samples.

    PubMed

    Alshishani, Anas; Salhimi, Salizawati Muhamad; Saad, Bahruddin

    2018-01-15

    A new salting-out assisted liquid-liquid extraction (SALLE) sample preparation method for the determination of the polar anti-diabetic biguanide drugs (metformin, buformin and phenformin) in blood plasma, urine and lake water samples were developed. The SALLE was performed by mixing samples (plasma (0.2mL), urine or lake water (1.0mL)) with acetonitrile (0.4mL for plasma, 0.5mL for urine or lake water), sodium hydroxide powder was then added for the phase separation. The effects of type of salting-out reagent, type of extraction solvent, volumes of acetonitrile and sample, amount of sodium hydroxide, vortexing and centrifugation times on the extraction efficiency were investigated. The upper layer, containing the biguanides, was directly injected into a HPLC unit using ZIC-HILIC column (150mm×2.1mm×3.5μm) and was detected at 236nm. The method was validated and calibration curves were linear with r 2 >0.99 over the range of 20-2000μgL -1 for plasma and 5-2000μgL -1 for urine and lake water samples. The limits of detection were in the range (3.8-5.6)μgL -1 , (0.8-1.5)μgL -1 and (0.3-0.8)μgL -1 for plasma, urine and lake water, respectively. The accuracies in the three matrices were within 87.3-103%, 87.4-109%, 82.2-109% of the nominal concentration for metformin, buformin and phenformin, respectively. The relative standard deviation for inter- and intra -day precision were in the range of 1.0-17% for all analytes in the three matrices. Copyright © 2017 Elsevier B.V. All rights reserved.

  4. Novel enzyme-linked immunosorbent assay for determination of fluvastatin in plasma at picogram level.

    PubMed

    Darwish, Ibrahim A; Al-Obaid, Abdul-Rahman M; Al-Malaq, Hamoud A

    2009-11-15

    For the first time, an enzyme-linked immunosorbent assay (ELISA) has been developed and validated for the determination of fluvastatin (FLV) in plasma samples at picogram level. The assay employed a polyclonal antibody that specifically recognizes FLV with high affinity, and FLV conjugate of bovine serum albumin (FLV-BSA) immobilized onto microplate wells as a solid-phase. The assay involved a competitive binding reaction between FLV, in plasma sample, and the immobilized FLV-BSA for the binding sites on a limited amount of the anti-FLV antibody. The bound anti-FLV antibody was quantified with horseradish peroxidase-labeled second anti-rabbit IgG antibody (HRP-IgG) and 3,3',5,5'-tetramethylbenzidine (TMB) as a substrate for the peroxidase enzyme. The concentration of FLV in the sample was quantified by its ability to inhibit the binding of the anti-FLV antibody to the immobilized FLV-BSA and subsequently the color intensity in the assay wells. The conditions for the proposed ELISA were investigated and the optimum conditions were employed in the determination of FLV in plasma samples. The assay limit of detection was 10 pg mL(-1) and the effective working range at relative standard deviations (RSD) of

  5. Experimental transition probabilities for Mn II spectral lines

    NASA Astrophysics Data System (ADS)

    Manrique, J.; Aguilera, J. A.; Aragón, C.

    2018-06-01

    Transition probabilities for 46 spectral lines of Mn II with wavelengths in the range 2000-3500 Å have been measured by CSigma laser-induced breakdown spectroscopy (Cσ-LIBS). For 28 of the lines, experimental data had not been reported previously. The Cσ-LIBS method, based in the construction of generalized curves of growth called Cσ graphs, avoids the error due to self-absorption. The samples used to generate the laser-induced plasmas are fused glass disks prepared from pure MnO. The Mn concentrations in the samples and the lines included in the study are selected to ensure the validity of the model of homogeneous plasma used. The results are compared to experimental and theoretical values available in the literature.

  6. A Novel and Rapid Method to Determine Doxycycline in Human Plasma by Liquid Chromatography Tandem Mass Spectrometry

    PubMed Central

    Krishna, A. Chaitanya; Sathiyaraj, M.; Saravanan, R. S.; Chelladurai, R.; Vignesh, R.

    2012-01-01

    A simple, rapid, specific and sensitive liquid chromatography tandem mass spectrometric method has been developed and validated for the determination of doxycycline from the human plasma. Doxycycline is extracted from human plasma by solid phase extraction. Demeclocycline was used as an internal standard. Detection was performed at transitions of 444.800→428.200 for doxycycline and 464.700→448.100 for demeclocycline using mass spectrometry. Chromatographic separation of analyte and internal standard were carried out using a reverse phase C18, column at 0.500 ml/min flow. The assay of doxycycline is linear over the range of 0.055-7.612 μg/ml, with a precision <14.83%, regression coefficient (r2)=0.9961 and the limit of quantification in plasma for doxycycline was 0.055 μg/ml. Mean extraction recovery obtained was 95.55%. Samples are stable at room temperature for 6 h, processed samples were stable at least for 30.20 h and also stable at three freeze-thaw cycles. The method has been used to perform pharmacokinetic and bioequivalence studies in human plasma. PMID:23798780

  7. Simple equation for calculation of plasma clearance for evaluation of renal function without urine collection in rats.

    PubMed

    Liu, Xiang; Peng, Dejun; Tian, Hao; Lu, Chengyu

    2017-01-01

    To develop an equation for the evaluation of renal function in rats using three dilutions of plasma samples and to validate this method by comparison with a reference method. The investigation was conducted in Sprague-Dawley (SD) rats after delivery of three doses of iohexol, with blood samples collected before and after dosage using a quantitative blood collection method. Plasma iohexol concentrations were detected by high performance liquid chromatography (HPLC). The extraction recovery of iohexol from plasma was >97.30% and the calibration curve was linear (r 2  = 0.9997) over iohexol concentrations ranging from 10 to 1000 µg/mL. The method had an RE of <9.310 and intra- and inter-day RSD of <5.137% and <3.693%, respectively. The plasma clearance values obtained from the equation correlated closely (r = 0.763) with those obtained using the reference method. The relatively correlation in the results obtained using the method under investigation and the reference method indicate that this new equation can be used for preliminary assessment of renal function in rats. © 2016 Asian Pacific Society of Nephrology.

  8. Quantification of low molecular weight selenium metabolites in human plasma after treatment with selenite in pharmacological doses by LC-ICP-MS.

    PubMed

    Flouda, Konstantina; Dersch, Julie Maria; Gabel-Jensen, Charlotte; Stürup, Stefan; Misra, Sougat; Björnstedt, Mikael; Gammelgaard, Bente

    2016-03-01

    The paper presents an analytical method for quantification of low molecular weight (LMW) selenium compounds in human plasma based on liquid chromatography inductively coupled plasma mass spectrometry (LC-ICP-MS) and post column isotope dilution-based quantification. Prior to analysis, samples were ultrafiltrated using a cut-off value of 3000 Da. The method was validated in aqueous solution as well as plasma using standards of selenomethionine (SeMet), Se-methylselenocysteine (MeSeCys), selenite, and the selenosugar Se-methylseleno-N-acetylgalactosamine (SeGal) for linearity, precision, recoveries, and limits of detection and quantitation with satisfactory results. The method was applied for analysis of a set of plasma samples from cancer patients receiving selenite treatment in a clinical trial. Three LMW selenium compounds were observed. The main compounds, SeGal and selenite were tentatively identified by retention time matching with standards in different chromatographic systems, while the third minor compound was not identified. The identity of the selenosugar was verified by ESI-MS-MS product ion scanning, while selenite was identified indirectly as the glutathione (GSH) reaction product, GS-Se-SG.

  9. Analytical and Clinical Validation of a Digital Sequencing Panel for Quantitative, Highly Accurate Evaluation of Cell-Free Circulating Tumor DNA

    PubMed Central

    Zill, Oliver A.; Sebisanovic, Dragan; Lopez, Rene; Blau, Sibel; Collisson, Eric A.; Divers, Stephen G.; Hoon, Dave S. B.; Kopetz, E. Scott; Lee, Jeeyun; Nikolinakos, Petros G.; Baca, Arthur M.; Kermani, Bahram G.; Eltoukhy, Helmy; Talasaz, AmirAli

    2015-01-01

    Next-generation sequencing of cell-free circulating solid tumor DNA addresses two challenges in contemporary cancer care. First this method of massively parallel and deep sequencing enables assessment of a comprehensive panel of genomic targets from a single sample, and second, it obviates the need for repeat invasive tissue biopsies. Digital SequencingTM is a novel method for high-quality sequencing of circulating tumor DNA simultaneously across a comprehensive panel of over 50 cancer-related genes with a simple blood test. Here we report the analytic and clinical validation of the gene panel. Analytic sensitivity down to 0.1% mutant allele fraction is demonstrated via serial dilution studies of known samples. Near-perfect analytic specificity (> 99.9999%) enables complete coverage of many genes without the false positives typically seen with traditional sequencing assays at mutant allele frequencies or fractions below 5%. We compared digital sequencing of plasma-derived cell-free DNA to tissue-based sequencing on 165 consecutive matched samples from five outside centers in patients with stage III-IV solid tumor cancers. Clinical sensitivity of plasma-derived NGS was 85.0%, comparable to 80.7% sensitivity for tissue. The assay success rate on 1,000 consecutive samples in clinical practice was 99.8%. Digital sequencing of plasma-derived DNA is indicated in advanced cancer patients to prevent repeated invasive biopsies when the initial biopsy is inadequate, unobtainable for genomic testing, or uninformative, or when the patient’s cancer has progressed despite treatment. Its clinical utility is derived from reduction in the costs, complications and delays associated with invasive tissue biopsies for genomic testing. PMID:26474073

  10. Association between the miRNA Signatures in Plasma and Bronchoalveolar Fluid in Respiratory Pathologies

    PubMed Central

    Molina-Pinelo, Sonia; Suárez, Rocío; Pastor, María Dolores; Nogal, Ana; Márquez-Martín, Eduardo; Martín-Juan, José; Carnero, Amancio; Paz-Ares, Luis

    2012-01-01

    The identification of new less invasive biomarkers is necessary to improve the detection and prognostic outcome of respiratory pathological processes. The measurement of miRNA expression through less invasive techniques such as plasma and serum have been suggested to analysis of several lung malignancies including lung cancer. These studies are assuming a common deregulated miRNA expression both in blood and lung tissue. The present study aimed to obtain miRNA representative signatures both in plasma and bronchoalveolar cell fraction that could serve as biomarker in respiratory diseases. Ten patients were evaluated to assess the expression levels of 381 miRNAs. We found that around 50% miRNAs were no detected in both plasma and bronchoalveolar cell fraction and only 20% of miRNAs showed similar expression in both samples. These results show a lack of association of miRNA signatures between plasma and bronchoalveolar cytology in the same patient. The profiles are not comparable; however, there is a similarity in the relative expression in a very small subset of miRNAs (miR-17, miR-19b, miR-195 and miR-20b) between both biological samples in all patients. This finding supports that the miRNAs profiles obtained from different biological samples have to be carefully validated to link with respiratory diseases. PMID:22430188

  11. Determination and pharmacokinetic study of pirfenidone in rat plasma by UPLC-MS/MS.

    PubMed

    Sun, Wei; Jiang, Zhe-li; Zhou, Lei; Chen, Rui-min; Wang, Zhe; Li, Wan-shu; Jiang, Shuo-min; Hu, Guo-xin; Chen, Rui-jie

    2015-02-15

    A rapid, sensitive and selective ultra-performance liquid chromatography tandem mass spectrometry (UPLC-MS/MS) was developed and validated for the determination and pharmacokinetic investigation of pirfenidone in rat plasma. Sample preparation was accomplished through a simple one-step deproteinization procedure with 0.2 mL of acetonitrile to a 0.1 mL plasma sample. Plasma samples were separated by UPLC on an Acquity UPLC BEH C18 column using a mobile phase consisting of acetonitrile-0.1% formic acid in water with gradient elution. The total run time was 3.0 min and the elution of pirfenidone was at 1.39 min. The detection was performed on a triple quadrupole tandem mass spectrometer in the multiple reaction-monitoring (MRM) mode using the respective transitions m/z 186.2→92.1 for pirfenidone and m/z 237.1→194.2 for carbamazepine (IS), respectively. The calibration curve was linear over the range of 5-2000 ng/mL with a lower limit of quantitation (LLOQ) of 5 ng/mL. Mean recovery of pirfenidone in plasma was in the range of 80.4-84.3%. Intra-day and inter-day precision were both <12.1%. This method was successfully applied in pharmacokinetic study after oral administration of 10.0mg/kg pirfenidone in rats. Copyright © 2015 Elsevier B.V. All rights reserved.

  12. Assays for hydrophilic and lipophilic antioxidant capacity (oxygen radical absorbance capacity (ORAC(FL))) of plasma and other biological and food samples.

    PubMed

    Prior, Ronald L; Hoang, Ha; Gu, Liwei; Wu, Xianli; Bacchiocca, Mara; Howard, Luke; Hampsch-Woodill, Maureen; Huang, Dejian; Ou, Boxin; Jacob, Robert

    2003-05-21

    Methods are described for the extraction and analysis of hydrophilic and lipophilic antioxidants, using modifications of the oxygen radical absorbing capacity (ORAC(FL)) procedure. These methods provide, for the first time, the ability to obtain a measure of "total antioxidant capacity" in the protein free plasma, using the same peroxyl radical generator for both lipophilic and hydrophilic antioxidants. Separation of the lipophilic and hydrophilic antioxidant fractions from plasma was accomplished by extracting with hexane after adding water and ethanol to the plasma (hexane/plasma/ethanol/water, 4:1:2:1, v/v). Lipophilic and hydrophilic antioxidants were efficiently partitioned between hexane and aqueous solvents. Conditions for controlling temperature effects and decreasing assay variability using fluorescein as the fluorescent probe were validated in different laboratories. Incubation (37 degrees C for at least 30 min) of the buffer to which AAPH was dissolved was critical in decreasing assay variability. Lipophilic antioxidants represented 33.1 +/- 1.5 and 38.2 +/- 1.9% of the total antioxidant capacity of the protein free plasma in two independent studies of 6 and 10 subjects, respectively. Methods are described for application of the assay techniques to other types of biological and food samples.

  13. Unsuccessful Detection of Plant MicroRNAs in Beer, Extra Virgin Olive Oil and Human Plasma After an Acute Ingestion of Extra Virgin Olive Oil.

    PubMed

    Micó, Victor; Martín, Roberto; Lasunción, Miguel A; Ordovás, Jose M; Daimiel, Lidia

    2016-03-01

    The recent description of the presence of exogenous plant microRNAs from rice in human plasma had profound implications for the interpretation of microRNAs function in human health. If validated, these results suggest that food should not be considered only as a macronutrient and micronutrient supplier but it could also be a way of genomic interchange between kingdoms. Subsequently, several studies have tried to replicate these results in rice and other plant foods and most of them have failed to find plant microRNAs in human plasma. In this scenario, we aimed to detect plant microRNAs in beer and extra virgin olive oil (EVOO)--two plant-derived liquid products frequently consumed in Spain--as well as in human plasma after an acute ingestion of EVOO. Our hypothesis was that microRNAs present in beer and EVOO raw material could survive manufacturing processes, be part of these liquid products, be absorbed by human gut and circulate in human plasma. To test this hypothesis, we first optimized the microRNA extraction protocol to extract microRNAs from beer and EVOO, and then tried to detect microRNAs in those samples and in plasma samples of healthy volunteers after an acute ingestion of EVOO.

  14. Application of real-time PCR of sex-independent insertion-deletion polymorphisms to determine fetal sex using cell-free fetal DNA from maternal plasma.

    PubMed

    Ho, Sherry Sze Yee; Barrett, Angela; Thadani, Henna; Asibal, Cecille Laureano; Koay, Evelyn Siew-Chuan; Choolani, Mahesh

    2015-07-01

    Prenatal diagnosis of sex-linked disorders requires invasive procedures, carrying a risk of miscarriage of up to 1%. Cell-free fetal DNA (cffDNA) present in cell-free DNA (cfDNA) from maternal plasma offers a non-invasive source of fetal genetic material for analysis. Detection of Y-chromosome sequences in cfDNA indicates presence of a male fetus; in the absence of a Y-chromosome signal a female fetus is inferred. We aimed to validate the clinical utility of insertion-deletion polymorphisms (INDELs) to confirm presence of a female fetus using cffDNA. Quantitative real-time PCR (qPCR) for the Y-chromosome-specific sequence, SRY, was performed on cfDNA from 82 samples at 6-39 gestational weeks. In samples without detectable SRY, qPCRs for eight INDELs were performed on maternal genomic DNA and cfDNA. Detection of paternally inherited fetal alleles in cfDNA negative for SRY confirmed a female fetus. Fetal sex was correctly determined in 77/82 (93.9%) cfDNA samples. SRY was detected in all 39 samples from male-bearing pregnancies, and none of the 43 female-bearing pregnancies (sensitivity and specificity of SRY qPCR is therefore 100%; 95% CI 91%-100%). Paternally inherited fetal alleles were detected in 38/43 samples with no SRY signal, confirming the presence of a female fetus (INDEL assay sensitivity is therefore 88.4%; 95% CI 74.1%-95.6%). Since paternally inherited fetal INDELs were not used in women bearing male fetuses, the specificity of INDELs cannot be calculated. Five cfDNA samples were negative for both SRY and INDELS. We have validated a non-invasive prenatal test to confirm fetal sex as early as 6 gestational weeks using cffDNA from maternal plasma.

  15. An ultra-high pressure liquid chromatography-tandem mass spectrometry method for the quantification of teicoplanin in plasma of neonates.

    PubMed

    Begou, O; Kontou, A; Raikos, N; Sarafidis, K; Roilides, E; Papadoyannis, I N; Gika, H G

    2017-03-15

    The development and validation of an ultra-high pressure liquid chromatography (UHPLC) tandem mass spectrometry (MS/MS) method was performed with the aim to be applied for the quantification of plasma teicoplanin concentrations in neonates. Pharmacokinetic data of teicoplanin in the neonatal population is very limited, therefore, a sensitive and reliable method for the determination of all isoforms of teicoplanin applied in a low volume of sample is of real importance. Teicoplanin main components were extracted by a simple acetonitrile precipitation step and analysed on a C18 chromatographic column by a triple quadrupole MS with electrospray ionization. The method provides quantitative data over a linear range of 25-6400ng/mL with LOD 8.5ng/mL and LOQ 25ng/mL for total teicoplanin. The method was applied in plasma samples from neonates to support pharmacokinetic data and proved to be a reliable and fast method for the quantification of teicoplanin concentration levels in plasma of infants during therapy in Intensive Care Unit. Copyright © 2016 Elsevier B.V. All rights reserved.

  16. Development and validation of an LC-MS/MS method for quantification of cyclic guanosine 3',5'-monophosphate (cGMP) in clinical applications: a comparison with a EIA method.

    PubMed

    Zhang, Yanhua; Dufield, Dawn; Klover, Jon; Li, Wenlin; Szekely-Klepser, Gabriella; Lepsy, Christopher; Sadagopan, Nalini

    2009-02-15

    An LC-MS/MS method was developed and validated to quantify endogenous cyclic guanosine 3',5'-monophosphate (cGMP) in human plasma. The LC-MS/MS and competitive enzyme immunoassay (EIA) assays were compared. cGMP concentrations of 20 human plasma samples were measured by both methods. For the MS-based assay, plasma samples were subjected to a simple protein precipitation procedure by acetonitrile prior to analysis by electrospray ionization LC-MS/MS. De-protonated analytes generated in negative ionization mode were monitored through multiple reaction monitoring (MRM). A stable isotope-labeled internal standard, (13)C(10),(15)N(5)-cGMP, which was biosynthesized in-house, was used in the LC-MS/MS method. The competitive EIA was validated using a commercially available cGMP fluorescence assay kit. The intra-assay accuracy and precision for MS-based assay for cGMP were 6-10.1% CV and -3.6% to 7.3% relative error (RE), respectively, while inter-assay precision and accuracy were 5.6-8.1% CV and -2.1% to 6.3% RE, respectively. The intra-assay accuracy and precision for EIA were 17.9-27.1% CV and -4.9% to 24.5% RE, respectively, while inter-assay precision and accuracy were 15.1-39.5% CV and -30.8% to 4.37% RE, respectively. Near the lower limits of detection, there was little correlation between the cGMP concentration values in human plasma generated by these two methods (R(2)=0.197, P=0.05). Overall, the MS-based assay offered better selectivity, recovery, precision and accuracy over a linear range of 0.5-20ng/mL. The LC-MS/MS method provides an effective tool for the quantitation of cGMP to support clinical mechanistic studies of curative pharmaceuticals.

  17. Development and validation of an UPLC-MS/MS method for the quantification of irinotecan, SN-38 and SN-38 glucuronide in plasma, urine, feces, liver and kidney: Application to a pharmacokinetic study of irinotecan in rats.

    PubMed

    Basu, Sumit; Zeng, Min; Yin, Taijun; Gao, Song; Hu, Ming

    2016-03-15

    The objective of this research is to develop and validate a sensitive and reproducible UPLC-MS/MS method to quantify irinotecan, its active metabolite SN-38 and SN-38 glucuronide (phase II metabolite of SN-38) simultaneously in different bio-matrices (plasma, urine, feces), tissues (liver and kidney) and to use the method to investigate its pharmacokinetic behavior in rats. Irinotecan, SN-38 and SN-38 glucuronide has been resolved and separated by C18 column using acetonitrile and 0.1% formic acid in water used as the mobile phases. Triple quadruple mass spectrometer using multiple reaction monitoring (MRM) with positive scan mode were employed to perform mass analysis. The results showed that the linear response range of irinotecan and SN-38 in plasma, feces, liver and kidney is 4.88-10000 nM, 39-5000 nM, 48.8-6250 nM and 48.8-6250 nM, respectively (R(2)>0.99). In case of SN-38 glucuronide, the standard curves were linear in the concentration range of 6.25-2000 nM, 4.88-1250 nM, 9.8-1250 nM and 9.8-1250 nM in plasma, feces, liver and kidney homogenates, respectively. The lower limit of detection (LLOD) of irinotecan, SN-38 and SN-38 glucuronide was determined to be less than 25 nM in all bio-matrices as well as tissue homogenates. Recoveries of irinotecan, SN-38 and SN-38 glucuronide at three different concentrations (low, medium and high) were not less than 85% at three different concentrations in plasma and feces. The percentage matrix factors in different bio-matrices and tissues were within 20%. The UPLC-MS/MS method was validated with intra-day and inter-day precision of less than 15% in plasma, feces, liver and kidney. Owing to the high sensitivity of this method, only 20 μl of plasma, urine and homogenates of liver, kidney and feces is needed. The validated method has been successfully employed for pharmacokinetic evaluation of irinotecan in male wistar rats to quantify irinotecan, SN-38 and SN-38 glucuronide in plasma, feces, and urine samples. Published by Elsevier B.V.

  18. Development and validation of an UPLC-MS/MS method for the quantification of irinotecan, SN 38 and SN-38 glucuronide in plasma, urine, feces, liver and kidney: Application to a pharmacokinetic study of irinotecan in rats

    PubMed Central

    Basu, Sumit; Zeng, Min; Yin, Taijun; Gao, Song; Hu, Ming

    2016-01-01

    The objective of this research is to develop and validate a sensitive and reproducible UPLC-MS/MS method to quantify irinotecan, its active metabolite SN-38 and SN-38 glucuronide (phase II metabolite of SN-38) simultaneously in different bio-matrices (plasma, urine, feces), tissues (liver and kidney) and to use the method to investigate its pharmacokinetic behavior in rats. Irinotecan, SN-38 and SN-38 glucuronide has been resolved and separated by C18 column using acetonitrile and 0.1% formic acid in water used as the mobile phases. Triple quadruple mass spectrometer using multiple reaction monitoring (MRM) with positive scan mode were employed to perform mass analysis. The results showed that the linear response range of irinotecan and SN-38 in plasma, feces, liver and kidney is 4.88 –10000 nM, 39 – 5000 nM, 48.8 –6250 nM and 48.8 – 6250 nM, respectively (R2 > 0.99). In case of SN-38 glucuronide, the standard curves were linear in the concentration range of 6.25 – 2000 nM, 4.88 – 1250 nM, 9.8 – 1250 nM and 9.8 – 1250 nM in plasma, feces, liver and kidney homogenates, respectively. The lower limit of detection (LLOD) of irinotecan, SN-38 and SN-38 glucuronide was determined to be less than 25 nM in all bio-matrices as well as tissue homogenates. Recoveries of irinotecan, SN-38 and SN-38 glucuronide at three different concentrations (low, medium and high) were not less than 85% at three different concentrations in plasma and feces. The percentage matrix factors in different bio-matrices and tissues were within 20%. The UPLC-MS/MS method was validated with intra-day and inter-day precision of less than 15% in plasma, feces, liver and kidney. Owing to the high sensitivity of this method, only 20 µl of plasma, urine and homogenates of liver, kidney and feces is needed. The validated method has been successfully employed for pharmacokinetic evaluation of irinotecan in male wistar rats to quantify irinotecan, SN-38 and SN-38 glucuronide in plasma, feces, and urine samples. PMID:26894853

  19. Simultaneous quantification of PGI2 and TXA2 metabolites in plasma and urine in NO-deficient mice by a novel UHPLC/MS/MS method.

    PubMed

    Kij, Agnieszka; Mateuszuk, Lukasz; Sitek, Barbara; Przyborowski, Kamil; Zakrzewska, Agnieszka; Wandzel, Krystyna; Walczak, Maria; Chlopicki, Stefan

    2016-09-10

    The balance between vascular prostacyclin (PGI2) generated mainly via cyclooxygenase-2 (COX-2) and its physiological antagonist platelet-derived thromboxane A2 (TXA2) formed by cyclooxygenase-1 (COX-1) determines cardiovascular homeostasis. In the present work, a novel bioanalytical method for simultaneous quantification of stable plasma and urinary metabolites of PGI2 (6-keto-PGF1α, 2,3-dinor-6-keto-PGF1α) and TXA2 (TXB2, 2,3-dinor-TXB2) using ultra high-performance liquid chromatography coupled with tandem mass spectrometry (UHPLC/MS/MS) was developed. The method was validated using artificial plasma and urine and linearity range, intra- and inter-day precision and accuracy, recovery of analytes, relative and absolute matrix effect and stability of analytes were determined. The use of artificial biofluids improved the method sensitivity as it eliminated the contribution of endogenous metabolites present in mice plasma and urine to validation procedure. The newly developed and validated method allowed to quantify 6-keto-PGF1α and TXB2 in mice plasma as well as 2,3-dinor-6-keto-PGF1α and 2,3-dinor-TXB2 in urine samples with high sensitivity and accuracy. The calibration range was established from 0.1 to 100ng/mL for all analytes using artificial biofluids and the recoveries were greater than 89.9%. All validated parameters met the criteria of acceptance specified in FDA and EMA guidance. This method was successfully employed for profiling of the changes in PGI2 and TXA2 generation in NO-deficient mice. This work demonstrated that NO-deficiency induced by L-NAME, evidenced by a fall in nitrite in plasma and urine, was associated with platelet activation, robust increase in TXB2 and mild increase in 6-keto-PGF1α concentration in plasma. Changes in 2,3-dinor-6-keto-PGF1α and 2,3-dinor-TXB2 concentration in urine were less evident suggesting that the measurements in plasma better reflect modest changes in PGI2/TXA2 homeostasis than measurements in urine. Copyright © 2016 Elsevier B.V. All rights reserved.

  20. Correlations between Fruit, Vegetables, Fish, Vitamins, and Fatty Acids Estimated by Web-Based Nonconsecutive Dietary Records and Respective Biomarkers of Nutritional Status.

    PubMed

    Lassale, Camille; Castetbon, Katia; Laporte, François; Deschamps, Valérie; Vernay, Michel; Camilleri, Géraldine M; Faure, Patrice; Hercberg, Serge; Galan, Pilar; Kesse-Guyot, Emmanuelle

    2016-03-01

    It is of major importance to measure the validity of self-reported dietary intake using web-based instruments before applying them in large-scale studies. This study aimed to validate self-reported intake of fish, fruit and vegetables, and selected micronutrient intakes assessed by a web-based self-administered dietary record tool used in the NutriNet-Santé prospective cohort study, against the following concentration biomarkers: plasma beta carotene, vitamin C, and n-3 polyunsaturated fatty acids. One hundred ninety-eight adult volunteers (103 men and 95 women, mean age=50.5 years) were included in the protocol: they completed 3 nonconsecutive-day dietary records and two blood samples were drawn 3 weeks apart. The study was conducted in the area of Paris, France, between October 2012 and May 2013. Reported fish, fruit and vegetables, and selected micronutrient intakes and plasma beta carotene, vitamin C, and n-3 polyunsaturated fatty acid levels were compared. Simple and adjusted Spearman's rank correlation coefficients were estimated after de-attenuation for intra-individual variation. Regarding food groups in men, adjusted correlations ranged from 0.20 for vegetables and plasma vitamin C to 0.49 for fruits and plasma vitamin C, and from 0.40 for fish and plasma c20:5 n-3 (eicosapentaenoic acid [EPA]) to 0.55 for fish and plasma c22:6 n-3 (docosahexaenoic acid). In women, correlations ranged from 0.13 (nonsignificant) for vegetables and plasma vitamin C to 0.41 for fruits and vegetables and plasma beta carotene, and from 0.27 for fatty fish and EPA to 0.54 for fish and EPA+docosahexaenoic acid. Regarding micronutrients, adjusted correlations ranged from 0.36 (EPA) to 0.58 (vitamin C) in men and from 0.32 (vitamin C) to 0.38 (EPA) in women. The findings suggest that three nonconsecutive web-based dietary records provide reasonable estimates of true intake of fruits, vegetables, fish, beta carotene, vitamin C, and n-3 fatty acids. Along with other validation studies, this study shows acceptable validity of using such diet-assessment methods in large epidemiologic surveys and broadens new perspectives for epidemiology. Copyright © 2016 Academy of Nutrition and Dietetics. Published by Elsevier Inc. All rights reserved.

  1. Immunoassays for the detection of nicergoline and its metabolites in human plasma.

    PubMed

    Ezan, E; Delestre, L; Legendre, S; Rivière, R; Doignon, J L; Grognet, J M

    2001-04-01

    In order to determine nicergoline pharmacokinetics after oral administration to humans, we have developed two radioimmunoassays, one directed against nicergoline and the other directed against known nicergoline metabolites. The assays were validated according to the recommendations of international regulatory agencies and their limits of quantification were 40 and 10 pg/ml, respectively. In order to further validate the methods, a chromatographic separation of immunoreactive entities was performed with samples from healthy volunteers who were given 15 mg of Sermion (nicergoline orally administered). Chromatographic determination of assay specificity showed that the metabolite radioimmunoassay recognised known nicergoline metabolites but also a new metabolite. Using the antibodies directed against nicergoline, we were unable to detect nicergoline in the human plasma. This suggests that nicergoline is absent in the circulation because of complete metabolism through its first-pass effect.

  2. Development and validation of amitriptyline and its metabolite in human plasma by ultra performance liquid chromatography-tandem mass spectrometry and its application to a bioequivalence study.

    PubMed

    Bhatt, Mitesh; Shah, Sanjay

    2010-11-01

    A method based on ultra performance liquid chromatography tandem mass spectrometry (UPLC-MS/MS) in combination with solid-phase extraction for sample pretreatment has been developed for the simultaneous analysis of amitriptyline and its main metabolite in human plasma. The extraction of the analytes from plasma samples was carried out by means of a selective SPE procedure using hydrophilic-lipophilic balance cartridges. The assay involves a simple solid-phase extraction (SPE) procedure of 0.2 mL of human plasma and analysis was performed on a triple-quadrupole tandem mass spectrometer by multiple reactions monitoring (MRM) mode via electrospray ionization (ESI). The standard calibration curve was linear over the ranges 0.370-95.539 ng/mL for amitriptyline and 0.365-94.374 ng/mL for nortriptyline, expressed by the linear correlation coefficient r², which was better than 0.995 for both. The intra- and inter-day precision and accuracy of the quality control samples were within 10.0%. The recovery was 85.3, 88.4 and 80.7% for amitriptyline, nortriptyline and doxepin respectively. Total run time was 1.2 min only for each sample, which makes it possible to analyze more than 400 samples per day. The method was highly reproducible and gave peaks with excellent chromatography properties. Copyright © 2010 John Wiley & Sons, Ltd.

  3. Novel stereoselective high-performance liquid chromatographic method for simultaneous determination of guaifenesin and ketorolac enantiomers in human plasma.

    PubMed

    Maher, Hadir M; Al-Taweel, Shorog M; Alshehri, Mona M; Alzoman, Nourah Z

    2014-10-01

    A novel method was developed for the simultaneous determination of guaifenesin (GUA) and ketorolac tromethamine (KET) enantiomers in plasma samples. Since GUA probably increases the absorption of coadministered drugs (e.g., KET), it would be extremely important to monitor KET plasma levels for the purpose of dose adjustment with a subsequent decrease in the side effects. Enantiomeric resolution was achieved on a polysaccharide-based chiral stationary phase, amylose-2, as a chiral selector under the normal phase (NP) mode and using ornidazole (ORN) as internal standard. This innovative method has the advantage of the ease and reliability of sample preparation for plasma samples. Sample clean-up was based on simply using methanol for protein precipitation followed by direct extraction of drug residues using ethanol. Both GUA and KET enantiomers were separated using an isocratic mobile phase composed of hexane/isopropanol/trifluoroacetic acid, 85:15:0.05 v/v/v. Peak area ratios were linear over the range 0.05-20 µg/mL for the four enantiomers S (+) GUA, R (-) GUA, R (+) KET, and S (-) KET. The method was fully validated according to the International Conference on Harmonization (ICH) guidelines in terms of system suitability, specificity, accuracy, precision, robustness, and solution stability. Finally, this procedure was innovative to apply the rationale of developing a chiral high-performance liquid chromatography (HPLC) procedure for the simultaneous quantitative analysis of drug isomers in clinical samples. © 2014 Wiley Periodicals, Inc.

  4. Validation of Reported Whole-Grain Intake from a Web-Based Dietary Record against Plasma Alkylresorcinol Concentrations in 8- to 11-Year-Olds Participating in a Randomized Controlled Trial.

    PubMed

    Biltoft-Jensen, Anja; Damsgaard, Camilla T; Andersen, Elisabeth W; Ygil, Karin H; Andersen, Rikke; Ege, Majken; Christensen, Tue; Thorsen, Anne-Vibeke; Tetens, Inge; Wu, Huaxing; Landberg, Rikard

    2016-02-01

    Whole-grain (WG) intake is important for human health, but accurate intake estimation is challenging. Use of a biomarker for WG intake provides a possible way to validate dietary assessment methods. Our aim was to validate WG intake from 2 diets reported by children, using plasma alkylresorcinol (AR) concentrations, and to investigate the 3-mo reproducibility of AR concentrations and reported WG intake. AR concentrations were analyzed in fasting blood plasma samples, and WG intake was estimated in a 7-d web-based diary by 750 participants aged 8-11 y in a 2 school meal × 3 mo crossover trial. Reported WG intake and plasma AR concentrations were compared when children ate their usual bread-based lunch (UBL) and when served a hot lunch meal (HLM). Correlations and cross-classification were used to rank subjects according to intake. The intraclass correlation coefficients (ICCs) between subjects' measurements at baseline and after the UBL were used to assess reproducibility. Correlations between reported WG wheat + rye intake and plasma AR were 0.40 and 0.37 (P < 0.001) for the UBL and the HLM diets, and 78% and 77% were classified in the same or adjacent quartiles for the UBL and HLM diets, respectively. The ICC over 3 mo was 0.47 (95% CI: 0.38, 0.55) for plasma total ARs and 0.64 (95% CI: 0.58, 0.70) for reported WG intake. Correlations were higher when using the AR C17:0 homolog as a biomarker, reflecting rye intake instead of plasma total ARs [UBL: r = 0.47; HLM: r = 0.43, P < 0.001; ICC = 0.51 (95% CI: 0.43, 0.59)]. Self-reported WG wheat + rye intake among children showed moderate correlations with plasma AR concentrations. Substantial intraindividual variation was found in WG intake and plasma AR concentrations. The AR homolog C17:0 may be used as a biomarker for WG intake when the WG intake primarily comes from rye as in the present study. This trial was registered at clinicaltrials.gov as NCT01457794. © 2016 American Society for Nutrition.

  5. Validation of a new point-of-care assay for determination of β-carotene concentration in bovine whole blood and plasma.

    PubMed

    Raila, Jens; Enjalbert, Francis; Mothes, Ralf; Hurtienne, Andrea; Schweigert, Florian J

    2012-03-01

    β-Carotene is an important precursor of vitamin A, and is associated with bovine fertility. β-Carotene concentrations in plasma are used to optimize β-carotene supplementation in cattle, but measurement requires specialized equipment to separate plasma and extract and measure β-carotene, either using spectrophotometry or high performance liquid chromatography (HPLC). The objective of this study was to validate a new 2-step point-of-care (POC) assay for measuring β-carotene in whole blood and plasma. β-carotene concentrations in plasma from 166 cows were measured using HPLC and compared with results obtained using a POC assay, the iCheck-iEx-Carotene test kit. Whole blood samples from 23 of these cattle were also evaluated using the POC assay and compared with HPLC-plasma results from the same 23 animals. The POC assay includes an extraction vial (iEx Carotene) and hand-held photometer (iCheck Carotene). Concentrations of β-carotene in plasma measured using the POC assay ranged from 0.40 to 15.84 mg/L (n = 166). No differences were observed between methods for assay of plasma (mean ± SD; n = 166): HPLC-plasma 4.23 ± 2.35 mg/L; POC-plasma 4.49 ± 2.36 mg/L. Similar good agreement was found when plasma analyzed using HPLC was compared with whole blood analyzed using the POC system (n = 23): HPLC-plasma 3.46 ± 2.12 mg/L; POC-whole blood 3.67 ± 2.29 mg/L. Concentrations of β-carotene can be measured in blood and plasma from cattle easily and rapidly using a POC assay, and results are comparable to those obtained by the highly sophisticated HPLC method. Immediate feedback regarding β-carotene deficiency facilitates rapid and appropriate optimization of β-carotene supplementation in feed. © 2012 American Society for Veterinary Clinical Pathology.

  6. Head-to-Head Comparison and Evaluation of 92 Plasma Protein Biomarkers for Early Detection of Colorectal Cancer in a True Screening Setting.

    PubMed

    Chen, Hongda; Zucknick, Manuela; Werner, Simone; Knebel, Phillip; Brenner, Hermann

    2015-07-15

    Novel noninvasive blood-based screening tests are strongly desirable for early detection of colorectal cancer. We aimed to conduct a head-to-head comparison of the diagnostic performance of 92 plasma-based tumor-associated protein biomarkers for early detection of colorectal cancer in a true screening setting. Among all available 35 carriers of colorectal cancer and a representative sample of 54 men and women free of colorectal neoplasms recruited in a cohort of screening colonoscopy participants in 2005-2012 (N = 5,516), the plasma levels of 92 protein biomarkers were measured. ROC analyses were conducted to evaluate the diagnostic performance. A multimarker algorithm was developed through the Lasso logistic regression model and validated in an independent validation set. The .632+ bootstrap method was used to adjust for the potential overestimation of diagnostic performance. Seventeen protein markers were identified to show statistically significant differences in plasma levels between colorectal cancer cases and controls. The adjusted area under the ROC curves (AUC) of these 17 individual markers ranged from 0.55 to 0.70. An eight-marker classifier was constructed that increased the adjusted AUC to 0.77 [95% confidence interval (CI), 0.59-0.91]. When validating this algorithm in an independent validation set, the AUC was 0.76 (95% CI, 0.65-0.85), and sensitivities at cutoff levels yielding 80% and 90% specificities were 65% (95% CI, 41-80%) and 44% (95% CI, 24-72%), respectively. The identified profile of protein biomarkers could contribute to the development of a powerful multimarker blood-based test for early detection of colorectal cancer. ©2015 American Association for Cancer Research.

  7. Development and Bioanalytical Validation of a Liquid Chromatographic-Tandem Mass Spectrometric (LC-MS/MS) Method for the Quantification of the CCR5 Antagonist Maraviroc in Human Plasma

    PubMed Central

    Emory, Joshua F.; Seserko, Lauren A.; Marzinke, Mark A.

    2014-01-01

    Background Maraviroc is a CCR5 antagonist that has been utilized as a viral entry inhibitor in the management of HIV-1. Current clinical trials are pursuing maraviroc drug efficacy in both oral and topical formulations. Therefore, in order to fully understand drug pharmacokinetics, a sensitive method is required to quantify plasma drug concentrations. Methods Maraviroc-spiked plasma was combined with acetonitrile containing an isotopically-labeled internal standard, and following protein precipitation, samples were evaporated to dryness and reconstituted for liquid chromatographic-tandem mass spectrometric (LC-MS/MS) analysis. Chromatographic separation was achieved on a Waters BEH C8, 50 × 2.1 mm UPLC column, with a 1.7 μm particle size and the eluent was analyzed using an API 4000 mass analyzer in selected reaction monitoring mode. The method was validated as per FDA Bioanalytical Method Validation guidelines. Results The analytical measuring range of the LC-MS/MS method is 0.5-1000 ng/ml. Calibration curves were generated using weighted 1/x2 quadratic regression. Inter-and intra-assay precision was ≤ 5.38% and ≤ 5.98%, respectively; inter-and intra-assay accuracy (%DEV) was ≤ 10.2% and ≤ 8.44%, respectively. Additional studies illustrated similar matrix effects between maraviroc and its internal standard, and that maraviroc is stable under a variety of conditions. Method comparison studies with a reference LC-MS/MS method show a slope of 0.948 with a Spearman coefficient of 0.98. Conclusions Based on the validation metrics, we have generated a sensitive and automated LC-MS/MS method for maraviroc quantification in human plasma. PMID:24561264

  8. Development and validation of a high performance liquid chromatography quantification method of levo-tetrahydropalmatine and its metabolites in plasma and brain tissues: application to a pharmacokinetic study.

    PubMed

    Abdallah, Inas A; Huang, Peng; Liu, Jing; Lee, David Y; Liu-Chen, Lee-Yuan; Hassan, Hazem E

    2017-04-01

    Levo-tetrahydropalmatine (l-THP) is an alkaloid isolated from Chinese medicinal herbs of the Corydalis and Stephania genera. It has been used in China for more than 40 years mainly as an analgesic with sedative/hypnotic effects. Despite its extensive use, its metabolism has not been quantitatively studied, nor there a sensitive reliable bioanalytical method for its quantification simultaneously with its metabolites. As such, the objective of this study was to develop and validate a sensitive and selective HPLC method for simultaneous quantification of l-THP and its desmethyl metabolites l-corydalmine (l-CD) and l-corypalmine (l-CP) in rat plasma and brain tissues. Rat plasma and brain samples were processed by liquid-liquid extraction using ethyl acetate. Chromatographic separation was achieved on a reversed-phase Symmetry® C 18 column (4.6 × 150 mm, 5 μm) at 25°C. The mobile phase consisted of acetonitrile-methanol-10 mm ammonium phosphate (pH 3) (10:30:60, v/v) and was used at a flow rate of 0.8 mL/min. The column eluent was monitored at excitation and emission wavelengths of 230 and 315 nm, respectively. The calibration curves were linear over the concentration range of 1-10,000 ng/mL. The intra- and interday reproducibility studies demonstrated accuracy and precision within the acceptance criteria of bioanalytical guidelines. The validated HPLC method was successfully applied to analyze samples from a pharmacokinetic study of l-THP in rats. Taken together, the developed method can be applied for bioanalysis of l-THP and its metabolites in rodents and potentially can be transferred for bioanalysis of human samples. Copyright © 2016 John Wiley & Sons, Ltd.

  9. Development and validation of sensitive LC-MS/MS assays for quantification of HP-β-CD in human plasma and CSF

    PubMed Central

    Jiang, Hui; Sidhu, Rohini; Fujiwara, Hideji; De Meulder, Marc; de Vries, Ronald; Gong, Yong; Kao, Mark; Porter, Forbes D.; Yanjanin, Nicole M.; Carillo-Carasco, Nuria; Xu, Xin; Ottinger, Elizabeth; Woolery, Myra; Ory, Daniel S.; Jiang, Xuntian

    2014-01-01

    2-Hydroxypropyl-β-cyclodextrin (HP-β-CD), a widely used excipient for drug formulation, has emerged as an investigational new drug for the treatment of Niemann-Pick type C1 (NPC1) disease, a neurodegenerative cholesterol storage disorder. Development of a sensitive quantitative LC-MS/MS assay to monitor the pharmacokinetics (PKs) of HP-β-CD required for clinical trials has been challenging owing to the dispersity of the HP-β-CD. To support a phase 1 clinical trial for ICV delivery of HP-β-CD in NPC1 patients, novel methods for quantification of HP-β-CD in human plasma and cerebrospinal fluid (CSF) using LC-MS/MS were developed and validated: a 2D-LC-in-source fragmentation-MS/MS (2D-LC-IF-MS/MS) assay and a reversed phase ultra performance LC-MS/MS (RP-UPLC-MS/MS) assay. In both assays, protein precipitation and “dilute and shoot” procedures were used to process plasma and CSF, respectively. The assays were fully validated and in close agreement, and allowed determination of PK parameters for HP-β-CD. The LC-MS/MS methods are ∼100-fold more sensitive than the current HPLC assay, and were successfully employed to analyze HP-β-CD in human plasma and CSF samples to support the phase 1 clinical trial of HP-β-CD in NPC1 patients. PMID:24868096

  10. Development and validation of sensitive LC-MS/MS assays for quantification of HP-β-CD in human plasma and CSF.

    PubMed

    Jiang, Hui; Sidhu, Rohini; Fujiwara, Hideji; De Meulder, Marc; de Vries, Ronald; Gong, Yong; Kao, Mark; Porter, Forbes D; Yanjanin, Nicole M; Carillo-Carasco, Nuria; Xu, Xin; Ottinger, Elizabeth; Woolery, Myra; Ory, Daniel S; Jiang, Xuntian

    2014-07-01

    2-Hydroxypropyl-β-cyclodextrin (HP-β-CD), a widely used excipient for drug formulation, has emerged as an investigational new drug for the treatment of Niemann-Pick type C1 (NPC1) disease, a neurodegenerative cholesterol storage disorder. Development of a sensitive quantitative LC-MS/MS assay to monitor the pharmacokinetics (PKs) of HP-β-CD required for clinical trials has been challenging owing to the dispersity of the HP-β-CD. To support a phase 1 clinical trial for ICV delivery of HP-β-CD in NPC1 patients, novel methods for quantification of HP-β-CD in human plasma and cerebrospinal fluid (CSF) using LC-MS/MS were developed and validated: a 2D-LC-in-source fragmentation-MS/MS (2D-LC-IF-MS/MS) assay and a reversed phase ultra performance LC-MS/MS (RP-UPLC-MS/MS) assay. In both assays, protein precipitation and "dilute and shoot" procedures were used to process plasma and CSF, respectively. The assays were fully validated and in close agreement, and allowed determination of PK parameters for HP-β-CD. The LC-MS/MS methods are ∼100-fold more sensitive than the current HPLC assay, and were successfully employed to analyze HP-β-CD in human plasma and CSF samples to support the phase 1 clinical trial of HP-β-CD in NPC1 patients. Copyright © 2014 by the American Society for Biochemistry and Molecular Biology, Inc.

  11. Validation of a sensitive LC/MS/MS method for the determination of telaprevir and its R-isomer in human plasma.

    PubMed

    Chen, Xinhui; Bushman, Lane R; McAllister, Kevin J; Anderson, Peter L; Kiser, Jennifer J

    2014-12-01

    The purpose of this study was to validate a reversed-phase high-performance liquid chromatographic (HPLC), tandem mass spectrometry (MS/MS) assay for the determination of telaprevir and its R-diastereomer (VRT-127394) in acidified and nonacidified human plasma. The chromatographic baseline separation of telaprevir and telaprevir-R was performed on a Waters XBridge(TM) BEH Shield C18 , 2.1 × 75 mm column with a 2.5 µm particle size, under isocratic conditions consisting of a mobile phase of 50:45:5 water-acetonitrile-isopropanol with 1% ammonia at 0.2 mL/min. This method utilized a stable isotope internal standard with 11 deuterium atoms on the structure of the telaprevir molecule (telaprevir-d11). An internal standard for the telaprevir-R (telaprevir-R-d11) was also prepared by incubating telaprevir-d11 in basic solution, which facilitated isomer inter-conversion. The detection and quantitation of telaprevir, telaprevir-R, telaprevir-IS and telaprevir-R-IS was achieved by positive ion electrospray (ESI+) MS/MS detection. The assay quantifiable limit was 5.0 ng/mL when 0.100 mL of acidified human plasma was extracted. Accuracy and precision were validated over the calibration range of 5.0-5000 ng/mL. It was demonstrated using patient samples that, contrary to previous recommendations, quantitation of telaprevir does not require acidified plasma. Copyright © 2014 John Wiley & Sons, Ltd.

  12. A high-performance liquid chromatography-tandem mass spectrometry method coupled with protein precipitation for determination of granisetron in human plasma and its application to a comparative pharmacokinetic study.

    PubMed

    Zhou, Ying; Jiang, Ji; Hu, Pei; Wang, Hongyun

    2014-12-01

    A rapid, simple and validated method based on liquid chromatography coupled with tandem mass spectrometry (LC-MS/MS) has been developed for the determination of granisetron in human plasma. Plasma samples were pre-purified by protein precipitation procedure. The chromatographic separation was achieved with Synergi Polar-RP (75 × 2 mm, 4 µm) column using a mixture of 5 mm pH4.0 ammonium formate and methanol (300:316, v/v) under isocratic conditions at a flow rate of 0.3 mL/min. The detection was performed on a triple quadrupole tandem mass spectrometer in multiple reaction monitoring mode using positive electrospray ionization. The analysis time was about 2.5 min. The method was fully validated over the concentration range 0.1-10 ng/mL. The lower limit of quantification was 0.1 ng/mL. Inter- and intra-batch precision was <6.1% and the accuracy was within 95.6-100.0%. The mean extraction recovery was 96.3%. Selectivity, matrix effect and stability were also validated. The method was applied to the comparative pharmacokinetic study of granisetron in Chinese healthy subjects. Copyright © 2014 John Wiley & Sons, Ltd.

  13. HPLC-ESI-MS/MS validated method for simultaneous quantification of zopiclone and its metabolites, N-desmethyl zopiclone and zopiclone-N-oxide in human plasma.

    PubMed

    Mistri, Hiren N; Jangid, Arvind G; Pudage, Ashutosh; Shrivastav, Pranav

    2008-03-15

    A simple, selective and sensitive isocratic HPLC method with triple quadrupole mass spectrometry detection has been developed and validated for simultaneous quantification of zopiclone and its metabolites in human plasma. The analytes were extracted using solid phase extraction, separated on Symmetry shield RP8 column (150 mm x 4.6 mm i.d., 3.5 microm particle size) and detected by tandem mass spectrometry with a turbo ion spray interface. Metaxalone was used as an internal standard. The method had a chromatographic run time of 4.5 min and linear calibration curves over the concentration range of 0.5-150 ng/mL for both zopiclone and N-desmethyl zopiclone and 1-150 ng/mL for zopiclone-N-oxide. The intra-batch and inter-batch accuracy and precision evaluated at lower limit of quantification and quality control levels were within 89.5-109.1% and 3.0-14.7%, respectively, for all the analytes. The recoveries calculated for the analytes and internal standard were > or = 90% from spiked plasma samples. The validated method was successfully employed for a comparative bioavailability study after oral administration of 7.5 mg zopiclone (test and reference) to 16 healthy volunteers under fasted condition.

  14. Lung Reference Set A Application: LaszloTakacs - Biosystems (2010) — EDRN Public Portal

    Cancer.gov

    We would like to access the NCI lung cancer Combined Pre-Validation Reference Set A in order to further validate a lung cancer diagnostic test candidate. Our test is based on a panel of antibodies which have been tested on 4 different cohorts (see below, paragraph “Preliminary Data and Methods”). This Reference Set A, whose clinical setting is “Diagnosis of lung cancer”, will be used to validate the panel of monoclonal antibodies which have been demonstrated by extensive data analysis to provide the best discrimination between controls and Lung Cancer patient plasma samples, sensitivity and specificity values from ROC analyses are superior than 85 %.

  15. Simultaneous determination of glucose, triglycerides, urea, cholesterol, albumin and total protein in human plasma by Fourier transform infrared spectroscopy: direct clinical biochemistry without reagents.

    PubMed

    Jessen, Torben E; Höskuldsson, Agnar T; Bjerrum, Poul J; Verder, Henrik; Sørensen, Lars; Bratholm, Palle S; Christensen, Bo; Jensen, Lene S; Jensen, Maria A B

    2014-09-01

    Direct measurement of chemical constituents in complex biologic matrices without the use of analyte specific reagents could be a step forward toward the simplification of clinical biochemistry. Problems related to reagents such as production errors, improper handling, and lot-to-lot variations would be eliminated as well as errors occurring during assay execution. We describe and validate a reagent free method for direct measurement of six analytes in human plasma based on Fourier-transform infrared spectroscopy (FTIR). Blood plasma is analyzed without any sample preparation. FTIR spectrum of the raw plasma is recorded in a sampling cuvette specially designed for measurement of aqueous solutions. For each analyte, a mathematical calibration process is performed by a stepwise selection of wavelengths giving the optimal least-squares correlation between the measured FTIR signal and the analyte concentration measured by conventional clinical reference methods. The developed calibration algorithms are subsequently evaluated for their capability to predict the concentration of the six analytes in blinded patient samples. The correlation between the six FTIR methods and corresponding reference methods were 0.87

  16. NASA GRC and MSFC Space-Plasma Arc Testing Procedures

    NASA Technical Reports Server (NTRS)

    Ferguson, Dale C.; Vayner, Boris V.; Galofaro, Joel T,; Hillard, G. Barry; Vaughn, Jason; Schneider, Todd

    2005-01-01

    Tests of arcing and current collection in simulated space plasma conditions have been performed at the NASA Glenn Research Center (GRC) in Cleveland, Ohio, for over 30 years and at the Marshall Space Flight Center (MSFC) in Huntsville, Alabama, for almost as long. During this period, proper test conditions for accurate and meaningful space simulation have been worked out, comparisons with actual space performance in spaceflight tests and with real operational satellites have been made, and NASA has achieved our own internal standards for test protocols. It is the purpose of this paper to communicate the test conditions, test procedures, and types of analysis used at NASA GRC and MSFC to the space environmental testing community at large, to help with international space-plasma arcing-testing standardization. To be discussed are: 1.Neutral pressures, neutral gases, and vacuum chamber sizes. 2. Electron and ion densities, plasma uniformity, sample sizes, and Debuy lengths. 3. Biasing samples versus self-generated voltages. Floating samples versus grounded. 4. Power supplies and current limits. Isolation of samples from power supplies during arcs. 5. Arc circuits. Capacitance during biased arc-threshold tests. Capacitance during sustained arcing and damage tests. Arc detection. Prevention sustained discharges during testing. 6. Real array or structure samples versus idealized samples. 7. Validity of LEO tests for GEO samples. 8. Extracting arc threshold information from arc rate versus voltage tests. 9. Snapover and current collection at positive sample bias. Glows at positive bias. Kapon (R) pyrolisis. 10. Trigger arc thresholds. Sustained arc thresholds. Paschen discharge during sustained arcing. 11. Testing for Paschen discharge threshold. Testing for dielectric breakdown thresholds. Testing for tether arcing. 12. Testing in very dense plasmas (ie thruster plumes). 13. Arc mitigation strategies. Charging mitigation strategies. Models. 14. Analysis of test results. Finally, the necessity of testing will be emphasized, not to the exclusion of modeling, but as part of a complete strategy for determining when and if arcs will occur, and preventing them from occurring in space.

  17. Qualitative and quantitative spectro-chemical analysis of dates using UV-pulsed laser induced breakdown spectroscopy and inductively coupled plasma mass spectrometry.

    PubMed

    Mehder, A O; Habibullah, Y B; Gondal, M A; Baig, Umair

    2016-08-01

    Laser Induced Breakdown Spectroscopy (LIBS) is demonstrated for the spectral analysis of nutritional and toxic elements present in several varieties of date fruit samples available in the Saudi Arabia market. The method analyzes the optical emission of a test sample when subjected to pulsed laser ablation. In this demonstration, our primary focus is on calcium (Ca) and magnesium (Mg), as nutritional elements, and on chromium (Cr), as a toxic element. The local thermodynamic equilibrium (LTE) condition was confirmed prior to the elemental characterization of date samples to ensure accuracy of the LIBS analysis. This was achieved by measuring parameters associated with the plasma, such as the electron temperature and the electron number density. These plasma parameters aid interpretation of processes such as ionization, dissociation, and excitation occurring in the plasma plume formed by ablating the date palm sample. The minimum detection limit was established from calibration curves that involved plotting the LIBS signal intensity as a function of standard date samples with known concentrations. The concentration of Ca and Mg detected in different varieties of date samples was between 187 and 515 and 35-196mgL(-1) respectively, while Cr concentration measured between 1.72 and 7.76mgL(-1). In order to optimize our LIBS system, we have studied how the LIBS signal intensity depends on the incident laser energy and the delay time. In order to validate our LIBS analysis results, standard techniques such as inductively coupled plasma mass spectrometry (ICP-MS) were also applied on an identical (duplicate) date samples as those used for the LIBS analysis. The LIBS results exhibit remarkable agreement with those obtained from the ICP-MS analysis. In addition, the finger print wavelengths of other elements present in date samples were also identified and are reported here, which has not been previously reported, to the best of our knowledge. Copyright © 2016 Elsevier B.V. All rights reserved.

  18. NASA GRC and MSFC Space-Plasma Arc Testing Procedures

    NASA Technical Reports Server (NTRS)

    Ferguson, Dale C.a; Vayner, Boris V.; Galofaro, Joel T.; Hillard, G. Barry; Vaughn, Jason; Schneider, Todd

    2005-01-01

    Tests of arcing and current collection in simulated space plasma conditions have been performed at the NASA Glenn Research Center (GRC) in Cleveland, Ohio, for over 30 years and at the Marshall Space flight Center (MSFC) for almost as long. During this period, proper test conditions for accurate and meaningful space simulation have been worked out, comparisons with actual space performance in spaceflight tests and with real operational satellites have been made, and NASA has achieved our own internal standards for test protocols. It is the purpose of this paper to communicate the test conditions, test procedures, and types of analysis used at NASA GRC and MSFC to the space environmental testing community at large, to help with international space-plasma arcing testing standardization. To be discussed are: 1. Neutral pressures, neutral gases, and vacuum chamber sizes. 2. Electron and ion densities, plasma uniformity, sample sizes, and Debye lengths. 3. Biasing samples versus self-generated voltages. Floating samples versus grounded. 4. Power supplies and current limits. Isolation of samples from power supplies during arcs. Arc circuits. Capacitance during biased arc-threshold tests. Capacitance during sustained arcing and damage tests. Arc detection. Preventing sustained discharges during testing. 5. Real array or structure samples versus idealized samples. 6. Validity of LEO tests for GEO samples. 7. Extracting arc threshold information from arc rate versus voltage tests. 8 . Snapover and current collection at positive sample bias. Glows at positive bias. Kapton pyrolization. 9. Trigger arc thresholds. Sustained arc thresholds. Paschen discharge during sustained arcing. 10. Testing for Paschen discharge thresholds. Testing for dielectric breakdown thresholds. Testing for tether arcing. 11. Testing in very dense plasmas (ie thruster plumes). 12. Arc mitigation strategies. Charging mitigation strategies. Models. 13. Analysis of test results. Finally, the necessity of testing will be emphasized, not to the exclusion of modeling, but as part of a complete strategy for determining when and if arcs will occur, and preventing them from occurring in space.

  19. Quantification of nicotine, cotinine, trans-3'-hydroxycotinine and varenicline in human plasma by a sensitive and specific UPLC-tandem mass-spectrometry procedure for a clinical study on smoking cessation.

    PubMed

    Dobrinas, Maria; Choong, Eva; Noetzli, Muriel; Cornuz, Jacques; Ansermot, Nicolas; Eap, Chin B

    2011-11-15

    A sensitive and specific ultra performance liquid chromatography-tandem mass spectrometry method for the simultaneous quantification of nicotine, its metabolites cotinine and trans-3'-hydroxycotinine and varenicline in human plasma was developed and validated. Sample preparation was realized by solid phase extraction of the target compounds and of the internal standards (nicotine-d4, cotinine-d3, trans-3'-hydroxycotinine-d3 and CP-533,633, a structural analog of varenicline) from 0.5 mL of plasma, using a mixed-mode cation exchange support. Chromatographic separations were performed on a hydrophilic interaction liquid chromatography column (HILIC BEH 2.1×100 mm, 1.7 μm). A gradient program was used, with a 10 mM ammonium formate buffer pH 3/acetonitrile mobile phase at a flow of 0.4 mL/min. The compounds were detected on a triple quadrupole mass spectrometer, operated with an electrospray interface in positive ionization mode and quantification was performed using multiple reaction monitoring. Matrix effects were quantitatively evaluated with success, with coefficients of variation inferior to 8%. The procedure was fully validated according to Food and Drug Administration guidelines and to Société Française des Sciences et Techniques Pharmaceutiques. The concentration range was 2-500 ng/mL for nicotine, 1-1000 ng/mL for cotinine, 2-1000 ng/mL for trans-3'-hydroxycotinine and 1-500 ng/mL for varenicline, according to levels usually measured in plasma. Trueness (86.2-113.6%), repeatability (1.9-12.3%) and intermediate precision (4.4-15.9%) were found to be satisfactory, as well as stability in plasma. The procedure was successfully used to quantify nicotine, its metabolites and varenicline in more than 400 plasma samples from participants in a clinical study on smoking cessation. Copyright © 2011 Elsevier B.V. All rights reserved.

  20. Gas-phase detection of solid-state fission product complexes for post-detonation nuclear forensic analysis

    DOE PAGES

    Stratz, S. Adam; Jones, Steven A.; Oldham, Colton J.; ...

    2016-06-27

    This study presents the first known detection of fission products commonly found in post-detonation nuclear debris samples using solid sample introduction and a uniquely coupled gas chromatography inductively-coupled plasma time-of-flight mass spectrometer. Rare earth oxides were chemically altered to incorporate a ligand that enhances the volatility of the samples. These samples were injected (as solids) into the aforementioned instrument and detected for the first time. Repeatable results indicate the validity of the methodology, and this capability, when refined, will prove to be a valuable asset for rapid post-detonation nuclear forensic analysis.

  1. Gas-phase detection of solid-state fission product complexes for post-detonation nuclear forensic analysis

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Stratz, S. Adam; Jones, Steven A.; Oldham, Colton J.

    This study presents the first known detection of fission products commonly found in post-detonation nuclear debris samples using solid sample introduction and a uniquely coupled gas chromatography inductively-coupled plasma time-of-flight mass spectrometer. Rare earth oxides were chemically altered to incorporate a ligand that enhances the volatility of the samples. These samples were injected (as solids) into the aforementioned instrument and detected for the first time. Repeatable results indicate the validity of the methodology, and this capability, when refined, will prove to be a valuable asset for rapid post-detonation nuclear forensic analysis.

  2. An LC-MS/MS method for rapid and sensitive high-throughput simultaneous determination of various protein kinase inhibitors in human plasma.

    PubMed

    Abdelhameed, Ali S; Attwa, Mohamed W; Kadi, Adnan A

    2017-02-01

    A reliable, high-throughput and sensitive LC-MS/MS procedure was developed and validated for the determination of five tyrosine kinase inhibitors in human plasma. Following their extraction from human plasma, samples were eluted on a RP Luna®-PFP 100 Å column using a mobile phase system composed of acetonitrile and 0.01 m ammonium formate in water (pH ~4.1) with a ratio of (50:50, v/v) flowing at 0.3 mL min -1 . The mass spectrometer was operating with electrospray ionization in the positive ion multiple reaction monitoring mode. The proposed methodology resulted in linear calibration plots with correlation coefficients values of r 2  = 0.9995-0.9999 from concentration ranges of 2.5-100 ng mL -1 for imatinib, 5.0-100 ng mL -1 for sorafenib, tofacitinib and afatinib, and 1.0-100 ng mL -1 for cabozantinib. The procedure was validated in terms of its specificity, limit of detection (0.32-1.71 ng mL -1 ), lower limit of quantification (0.97-5.07 ng mL -1 ), intra- and inter assay accuracy (-3.83 to +2.40%) and precision (<3.37%), matrix effect and recovery and stability. Our results demonstrated that the proposed method is highly reliable for routine quantification of the investigated tyrosine kinase inhibitors in human plasma and can be efficiently applied in the rapid and sensitive analysis of their clinical samples. Copyright © 2016 John Wiley & Sons, Ltd.

  3. Determination of valproic acid in human plasma using dispersive liquid-liquid microextraction followed by gas chromatography-flame ionization detection

    PubMed Central

    Fazeli-Bakhtiyari, Rana; Panahi-Azar, Vahid; Sorouraddin, Mohammad Hossein; Jouyban, Abolghasem

    2015-01-01

    Objective(s): Dispersive liquid-liquid microextraction coupled with gas chromatography (GC)-flame ionization detector was developed for the determination of valproic acid (VPA) in human plasma. Materials and Methods: Using a syringe, a mixture of suitable extraction solvent (40 µl chloroform) and disperser (1 ml acetone) was quickly added to 10 ml of diluted plasma sample containing VPA (pH, 1.0; concentration of NaCl, 4% (w/v)), resulting in a cloudy solution. After centrifugation (6000 rpm for 6 min), an aliquot (1 µl) of the sedimented organic phase was removed using a 1-µl GC microsyringe and injected into the GC system for analysis. One variable at a time optimization method was used to study various parameters affecting the extraction efficiency of target analyte. Then, the developed method was fully validated for its accuracy, precision, recovery, stability, and robustness. Results: Under the optimum extraction conditions, good linearity range was obtained for the calibration graph, with correlation coefficient higher than 0.998. Limit of detection and lower limit of quantitation were 3.2 and 6 μg/ml, respectively. The relative standard deviations of intra and inter-day analysis of examined compound were less than 11.5%. The relative recoveries were found in the range of 97 to 107.5%. Finally, the validated method was successfully applied to the analysis of VPA in patient sample. Conclusion: The presented method has acceptable levels of precision, accuracy and relative recovery and could be used for therapeutic drug monitoring of VPA in human plasma. PMID:26730332

  4. A simple, rapid and sensitive liquid chromatography-tandem mass spectrometry method for the determination of dienogest in human plasma and its pharmacokinetic applications under fasting.

    PubMed

    Pallapothu, Leela Mohan Kumar; Batta, Neelima; Pigili, Ravi Kumar; Yejella, Rajendra Prasad

    2015-02-01

    A simple, rapid and sensitive analytical method using liquid chromatography coupled to tandem mass spectrometry (LC-MS/MS) detection with positive ion electrospray ionization was developed for the determination of dienogest in human K2 EDTA plasma using levonorgestrel d6 as an internal standard (IS). Dienogest and IS were extracted from human plasma using simple liquid-liquid extraction. Chromatographic separation was achieved on a Zorbax XDB-Phenyl column (4.6 × 75 mm, 3.5 µm) under isocratic conditions using acetonitrile-5 mm ammonium acetate (70:30, v/v) at a flow rate of 0.60 mL/min. The protonated precursor to product ion transitions monitored for dienogest and IS were at m/z 312.30 → 135.30 and 319.00 → 251.30, respectively. The method was validated with a linearity range of 1.003-200.896 ng/mL having a total analysis time for each chromatograph of 3.0 min. The method has shown tremendous reproducibility with intra- and inter-day precision (coefficient of variation) <3.97 and 6.10%, respectively, and accuracy within ±4.0% of nominal values. The validated method was applied to a pharmacokinetic study in human plasma samples generated after administration of a single oral dose of 2.0 mg dienogest tablets to healthy female volunteers and was proved to be highly reliable for the analysis of clinical samples. Copyright © 2014 John Wiley & Sons, Ltd.

  5. A novel ultra performance liquid chromatography-tandem mass spectrometry method for the determination of sucrose octasulfate in dog plasma.

    PubMed

    Ke, Yuyong; Li, Steve Lianghong; Chang, Linda Dongxia; Kapanadze, Theo

    2015-01-26

    A novel, specific and sensitive bioanalytical method has been developed for the determination of sucrose octasulfate (SOS) in dog plasma and urine using ion-pair reversed-phase ultraperformance liquid chromatography coupled with electrospray triple quadruple mass spectrometry (IPRP-UPLC ESI MS/MS). (13)C-labeled sucrose octasulfate-(13)C12 sodium salt is used as the internal standard. 200 μL of plasma or serum sample is extracted using weak anion exchange solid phase cartridge. In this method, a polar amide column is employed for the liquid chromatograph (LC) separation while the diethylamine and formic acid buffer is used as the ion-pairing reagent. The low limitation of quantitation of sucrose octasulfate is 0.20 ng on the column with a signal to noise ratio larger than 50. Parameters such as linearity, accuracy and precision have been validated in full compliance with the FDA guidelines for the bioanalytical method development and validation. A linear regression model fit the calibration curve very well with R>0.99. The bias and coefficient of variation of all levels of QCs are within the range of 15%. The selectivity, matrix effect and stabilities of analytes in solution and matrix have also been evaluated and the results met the acceptance criteria according to the guidelines. Based on these results, the method has qualified to analyze sucrose octasulfate in dog plasma for clinic research. This method has been applied to 1000 preclinical samples. Copyright © 2014 Elsevier B.V. All rights reserved.

  6. Determination of triapine, a ribonucleotide reductase inhibitor, in human plasma by liquid chromatography tandem mass spectrometry.

    PubMed

    Feng, Ye; Kunos, Charles A; Xu, Yan

    2015-09-01

    Triapine is an inhibitor of ribonucleotide reductase (RNR). Studies have shown that triapine significantly decreases the activity of RNR and enhanced the radiation-mediated cytotoxicity in cervical and colon cancer. In this work, we have developed and validated a selective and sensitive LC-MS/MS method for the determination of triapine in human plasma. In this method, 2-[(3-fluoro-2-pyridinyl)methylene] hydrazinecarbothioamide (NSC 266749) was used as the internal standard (IS); plasma samples were prepared by deproteinization with acetonitrile; tripaine and the IS were separated on a Waters Xbridge Shield RP18 column (3.5 µm; 2.1 × 50 mm) using a mobile phase containing 25.0% methanol and 75.0% ammonium bicarbonate buffer (10.0 mM, pH 8.50; v/v); column eluate was monitored by positive turbo-ionspray tandem mass spectrometry; and quantitation of triapine was carried out in multiple-reaction-monitoring mode. The method developed had a linear calibration range of 0.250-50.0 ng/mL with correlation coefficient of 0.999 for triapine in human plasma. The IS-normalized recovery and the IS-normalized matrix factor of triapine were 101-104% and 0.89-1.05, respectively. The accuracy expressed as percentage error and precision expressed as coefficient of variation were ≤±6 and ≤8%, respectively. The validated LC-MS/MS method was applied to the measurement of triapine in patient samples from a phase I clinical trial. Copyright © 2015 John Wiley & Sons, Ltd.

  7. Development and validation of an LC-MS/MS method for the toxicokinetic study of deoxynivalenol and its acetylated derivatives in chicken and pig plasma.

    PubMed

    Broekaert, N; Devreese, M; De Mil, T; Fraeyman, S; De Baere, S; De Saeger, S; De Backer, P; Croubels, S

    2014-11-15

    This study aims to develop an LC-MS/MS method allowing the determination of 3-acetyl-deoxynivalenol, 15-acetyl-deoxynivalenol, deoxynivalenol and its main in vivo metabolite, deepoxy-deoxynivalenol, in broiler chickens and pigs. These species have a high exposure to these toxins, given their mainly cereal based diet. Several sample cleanup strategies were tested and further optimized by means of fractional factorial designs. A simple and straightforward sample preparation method was developed consisting out of a deproteinisation step with acetonitrile, followed by evaporation of the supernatant and reconstitution in water. The method was single laboratory validated according to European guidelines and found to be applicable for the intended purpose, with a linear response up to 200ngml(-1) and limits of quantification of 0.1-2ngml(-1). As a proof of concept, biological samples from a broiler chicken that received either deoxynivalenol, 3- or 15-acetyl-deoxynivalenol were analyzed. Preliminary results indicate nearly complete hydrolysis of 3-acetyl-deoxynivalenol to deoxynivalenol; and to a lesser extent of 15-acetyl-deoxynivalenol to deoxynivalenol. No deepoxy-deoxynivalenol was detected in any of the plasma samples. The method will be applied to study full toxicokinetic properties of deoxynivalenol, 3-acetyl-deoxynivalenol and 15-acetyl-deoxynivalenol in broiler chickens and pigs. Copyright © 2014 Elsevier B.V. All rights reserved.

  8. Determination of chloramphenicol residues in meat, seafood, egg, honey, milk, plasma and urine with liquid chromatography-tandem mass spectrometry, and the validation of the method based on 2002/657/EC.

    PubMed

    Rønning, Helene Thorsen; Einarsen, Kristin; Asp, Tone Normann

    2006-06-23

    A simple and rapid method for the determination and confirmation of chloramphenicol in several food matrices with LC-MS/MS was developed. Following addition of d5-chloramphenicol as internal standard, meat, seafood, egg, honey and milk samples were extracted with acetonitrile. Chloroform was then added to remove water. After evaporation, the residues were reconstituted in methanol/water (3+4) before injection. The urine and plasma samples were after addition of internal standard applied to a Chem Elut extraction cartridge, eluted with ethyl acetate, and hexane washed. Also these samples were reconstituted in methanol/water (3+4) after evaporation. By using an MRM acquisition method in negative ionization mode, the transitions 321-->152, 321-->194 and 326-->157 were used for quantification, confirmation and internal standard, respectively. Quantification of chloramphenicol positive samples regardless of matrix could be achieved with a common water based calibration curve. The validation of the method was based on EU-decision 2002/657 and different ways of calculating CCalpha and CCbeta were evaluated. The common CCalpha and CCbeta for all matrices were 0.02 and 0.04 microg/kg for the 321-->152 ion transition, and 0.02 and 0.03 microg/kg for the 321-->194 ion transition. At fortification level 0.1 microg/kg the within-laboratory reproducibility is below 25%.

  9. Exploring the Process of Energy Generation in Pathophysiology by Targeted Metabolomics: Performance of a Simple and Quantitative Method.

    PubMed

    Riera-Borrull, Marta; Rodríguez-Gallego, Esther; Hernández-Aguilera, Anna; Luciano, Fedra; Ras, Rosa; Cuyàs, Elisabet; Camps, Jordi; Segura-Carretero, Antonio; Menendez, Javier A; Joven, Jorge; Fernández-Arroyo, Salvador

    2016-01-01

    Abnormalities in mitochondrial metabolism and regulation of energy balance contribute to human diseases. The consequences of high fat and other nutrient intake, and the resulting acquired mitochondrial dysfunction, are essential to fully understand common disorders, including obesity, cancer, and atherosclerosis. To simultaneously and noninvasively measure and quantify indirect markers of mitochondrial function, we have developed a method based on gas chromatography coupled to quadrupole-time of flight mass spectrometry and an electron ionization interface, and validated the system using plasma from patients with peripheral artery disease, human cancer cells, and mouse tissues. This approach was used to increase sensibility in the measurement of a wide dynamic range and chemical diversity of multiple intermediate metabolites used in energy metabolism. We demonstrate that our targeted metabolomics method allows for quick and accurate identification and quantification of molecules, including the measurement of small yet significant biological changes in experimental samples. The apparently low process variability required for its performance in plasma, cell lysates, and tissues allowed a rapid identification of correlations between interconnected pathways. Our results suggest that delineating the process of energy generation by targeted metabolomics can be a valid surrogate for predicting mitochondrial dysfunction in biological samples. Importantly, when used in plasma, targeted metabolomics should be viewed as a robust and noninvasive source of biomarkers in specific pathophysiological scenarios.

  10. Exploring the Process of Energy Generation in Pathophysiology by Targeted Metabolomics: Performance of a Simple and Quantitative Method

    NASA Astrophysics Data System (ADS)

    Riera-Borrull, Marta; Rodríguez-Gallego, Esther; Hernández-Aguilera, Anna; Luciano, Fedra; Ras, Rosa; Cuyàs, Elisabet; Camps, Jordi; Segura-Carretero, Antonio; Menendez, Javier A.; Joven, Jorge; Fernández-Arroyo, Salvador

    2016-01-01

    Abnormalities in mitochondrial metabolism and regulation of energy balance contribute to human diseases. The consequences of high fat and other nutrient intake, and the resulting acquired mitochondrial dysfunction, are essential to fully understand common disorders, including obesity, cancer, and atherosclerosis. To simultaneously and noninvasively measure and quantify indirect markers of mitochondrial function, we have developed a method based on gas chromatography coupled to quadrupole-time of flight mass spectrometry and an electron ionization interface, and validated the system using plasma from patients with peripheral artery disease, human cancer cells, and mouse tissues. This approach was used to increase sensibility in the measurement of a wide dynamic range and chemical diversity of multiple intermediate metabolites used in energy metabolism. We demonstrate that our targeted metabolomics method allows for quick and accurate identification and quantification of molecules, including the measurement of small yet significant biological changes in experimental samples. The apparently low process variability required for its performance in plasma, cell lysates, and tissues allowed a rapid identification of correlations between interconnected pathways. Our results suggest that delineating the process of energy generation by targeted metabolomics can be a valid surrogate for predicting mitochondrial dysfunction in biological samples. Importantly, when used in plasma, targeted metabolomics should be viewed as a robust and noninvasive source of biomarkers in specific pathophysiological scenarios.

  11. Simultaneous LC-MS/MS determination of phenylbutyrate, phenylacetate benzoate and their corresponding metabolites phenylacetylglutamine and hippurate in blood and urine.

    PubMed

    Laryea, Maurice D; Herebian, Diran; Meissner, Thomas; Mayatepek, Ertan

    2010-12-01

    Inborn errors of urea metabolism result in hyperammonemia. Treatment of urea cycle disorders can effectively lower plasma ammonium levels and results in survival in the majority of patients. Available medications for treating urea cycle disorders include sodium benzoate (BA), sodium phenylacetate (PAA), and sodium phenylbutyrate (PBA) and are given to provide alternate routes for disposition of waste nitrogen excretion. In this study, we develop and validate a liquid chromatography tandem mass spectrometry (LC-MS/MS) method for simultaneous determination of benzoic acid, phenylacetic acid, phenylbutyric acid, phenylacetylglutamine, and hippuric acid in plasma and urine from children with inborn errors of urea synthesis. Plasma extracts and diluted urine samples were injected on a reverse-phase column and identified and quantified by selected reaction monitoring (SRM) in negative ion mode. Deuterated analogues served as internal standards. Analysis time was 7 min. Assay precision, accuracy, and linearity and sample stability were determined using enriched samples. Quantification limits of the method were 100 ng/ml (0.3-0.8 μmol/L) for all analytes, and recoveries were >90%. Inter- and intraday relative standard deviations were <10%. Our newly developed LC-MS/MS represents a robust, sensitive, and rapid method that allows simultaneous determination of the five compounds in plasma and urine.

  12. The materials irradiation experiment for testing plasma facing materials at fusion relevant conditions

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Garrison, L. M., E-mail: garrisonlm@ornl.gov; Egle, B. J.; Fusion Technology Institute, University of Wisconsin-Madison, 1500 Engineering Drive, Madison, Wisconsin 53706

    2016-08-15

    The Materials Irradiation Experiment (MITE-E) was constructed at the University of Wisconsin-Madison Inertial Electrostatic Confinement Laboratory to test materials for potential use as plasma-facing materials (PFMs) in fusion reactors. PFMs in fusion reactors will be bombarded with x-rays, neutrons, and ions of hydrogen and helium. More needs to be understood about the interactions between the plasma and the materials to validate their use for fusion reactors. The MITE-E simulates some of the fusion reactor conditions by holding samples at temperatures up to 1000 °C while irradiating them with helium or deuterium ions with energies from 10 to 150 keV. The ionmore » gun can irradiate the samples with ion currents of 20 μA–500 μA; the typical current used is 72 μA, which is an average flux of 9 × 10{sup 14} ions/(cm{sup 2} s). The ion gun uses electrostatic lenses to extract and shape the ion beam. A variable power (1-20 W), steady-state, Nd:YAG laser provides additional heating to maintain a constant sample temperature during irradiations. The ion beam current reaching the sample is directly measured and monitored in real-time during irradiations. The ion beam profile has been investigated using a copper sample sputtering experiment. The MITE-E has successfully been used to irradiate polycrystalline and single crystal tungsten samples with helium ions and will continue to be a source of important data for plasma interactions with materials.« less

  13. Trace elemental composition of curry by inductively coupled plasma optical emission spectrometry (ICP-OES).

    PubMed

    Gonzálvez, A; Armenta, S; De La Guardia, M

    2008-01-01

    A methodology based on inductively coupled plasma optical emission spectrometry (ICP-OES) after microwave-assisted acid digestion was developed to determine the content of traces elements in curry samples from the Spanish market. The methodology was validated in terms of accuracy by the analysis of citrus and tomato leaf reference materials achieving comparable results with the certified values. The trace metal content of curry samples was compared with data available from previously published reports concerning Indian samples, especially in terms of heavy metal composition, in order to guarantee the quality of the commercially available spices in the European countries. Values found for the analysis of arsenic, lead and cadmium were significantly lower than the maximum limit allowed by European Union statutory limits for heavy metals and lower than those obtained for Indian curry leaves reported by Indian research teams by using neutron activation and γ-ray analysis.

  14. Use of laser ablation-inductively coupled plasma-time of flight-mass spectrometry to identify the elemental composition of vanilla and determine the geographic origin by discriminant function analysis.

    PubMed

    Hondrogiannis, Ellen M; Ehrlinger, Erin; Poplaski, Alyssa; Lisle, Meredith

    2013-11-27

    A total of 11 elements found in 25 vanilla samples from Uganda, Madagascar, Indonesia, and Papua New Guinea were measured by laser ablation-inductively coupled plasma-time-of-flight-mass spectrometry (LA-ICP-TOF-MS) for the purpose of collecting data that could be used to discriminate among the origins. Pellets were prepared of the samples, and elemental concentrations were obtained on the basis of external calibration curves created using five National Institute of Standards and Technology (NIST) standards and one Chinese standard with (13)C internal standardization. These curves were validated using NIST 1573a (tomato leaves) as a check standard. Discriminant analysis was used to successfully classify the vanilla samples by their origin. Our method illustrates the feasibility of using LA-ICP-TOF-MS with an external calibration curve for high-throughput screening of spice screening analysis.

  15. Rapid determination of 237Np in soil samples by multi-collector inductively-coupled plasma mass spectrometry and gamma spectrometry.

    PubMed

    Yi, Xiaowei; Shi, Yanmei; Xu, Jiang; He, Xiaobing; Zhang, Haitao; Lin, Jianfeng

    A radiochemical procedure is developed for the determination of 237 Np in soil with multi-collector inductively-coupled plasma mass spectrometry (MC-ICP-MS) and gamma-spectrometry. 239 Np (milked from 243 Am) was used as an isotopic tracer for chemical yield determination. The neptunium in the soil is separated by thenoyl-trifluoracetone extraction from 1 M HNO 3 solution after reducing Np to Np(IV) with ferrous sulfamate, and then purified with Dowex 1 × 2 anion exchange resin. 239 Np in the resulting solution is measured with gamma-spectrometry for chemical yield determination while the 237 Np is measured with MC-ICP-MS. Measurement results for soil samples are presented together with those for two reference samples. By comparing the determined value with the reference value of the 237 Np activity concentration, the feasibility of the procedure was validated.

  16. Determination of rivaroxaban in patient’s plasma samples by anti-Xa chromogenic test associated to High Performance Liquid Chromatography tandem Mass Spectrometry (HPLC-MS/MS)

    PubMed Central

    Derogis, Priscilla Bento Matos; Sanches, Livia Rentas; de Aranda, Valdir Fernandes; Colombini, Marjorie Paris; Mangueira, Cristóvão Luis Pitangueira; Katz, Marcelo; Faulhaber, Adriana Caschera Leme; Mendes, Claudio Ernesto Albers; Ferreira, Carlos Eduardo dos Santos; França, Carolina Nunes; Guerra, João Carlos de Campos

    2017-01-01

    Rivaroxaban is an oral direct factor Xa inhibitor, therapeutically indicated in the treatment of thromboembolic diseases. As other new oral anticoagulants, routine monitoring of rivaroxaban is not necessary, but important in some clinical circumstances. In our study a high-performance liquid chromatography-tandem mass spectrometry (HPLC-MS/MS) method was validated to measure rivaroxaban plasmatic concentration. Our method used a simple sample preparation, protein precipitation, and a fast chromatographic run. It was developed a precise and accurate method, with a linear range from 2 to 500 ng/mL, and a lower limit of quantification of 4 pg on column. The new method was compared to a reference method (anti-factor Xa activity) and both presented a good correlation (r = 0.98, p < 0.001). In addition, we validated hemolytic, icteric or lipemic plasma samples for rivaroxaban measurement by HPLC-MS/MS without interferences. The chromogenic and HPLC-MS/MS methods were highly correlated and should be used as clinical tools for drug monitoring. The method was applied successfully in a group of 49 real-life patients, which allowed an accurate determination of rivaroxaban in peak and trough levels. PMID:28170419

  17. Clinical validation of an ultra high-throughput spiral microfluidics for the detection and enrichment of viable circulating tumor cells.

    PubMed

    Khoo, Bee Luan; Warkiani, Majid Ebrahimi; Tan, Daniel Shao-Weng; Bhagat, Ali Asgar S; Irwin, Darryl; Lau, Dawn Pingxi; Lim, Alvin S T; Lim, Kiat Hon; Krisna, Sai Sakktee; Lim, Wan-Teck; Yap, Yoon Sim; Lee, Soo Chin; Soo, Ross A; Han, Jongyoon; Lim, Chwee Teck

    2014-01-01

    Circulating tumor cells (CTCs) are cancer cells that can be isolated via liquid biopsy from blood and can be phenotypically and genetically characterized to provide critical information for guiding cancer treatment. Current analysis of CTCs is hindered by the throughput, selectivity and specificity of devices or assays used in CTC detection and isolation. Here, we enriched and characterized putative CTCs from blood samples of patients with both advanced stage metastatic breast and lung cancers using a novel multiplexed spiral microfluidic chip. This system detected putative CTCs under high sensitivity (100%, n = 56) (Breast cancer samples: 12-1275 CTCs/ml; Lung cancer samples: 10-1535 CTCs/ml) rapidly from clinically relevant blood volumes (7.5 ml under 5 min). Blood samples were completely separated into plasma, CTCs and PBMCs components and each fraction were characterized with immunophenotyping (Pan-cytokeratin/CD45, CD44/CD24, EpCAM), fluorescence in-situ hybridization (FISH) (EML4-ALK) or targeted somatic mutation analysis. We used an ultra-sensitive mass spectrometry based system to highlight the presence of an EGFR-activating mutation in both isolated CTCs and plasma cell-free DNA (cf-DNA), and demonstrate concordance with the original tumor-biopsy samples. We have clinically validated our multiplexed microfluidic chip for the ultra high-throughput, low-cost and label-free enrichment of CTCs. Retrieved cells were unlabeled and viable, enabling potential propagation and real-time downstream analysis using next generation sequencing (NGS) or proteomic analysis.

  18. Phosphoproteins in extracellular vesicles as candidate markers for breast cancer

    PubMed Central

    Chen, I-Hsuan; Xue, Liang; Hsu, Chuan-Chih; Paez, Juan Sebastian Paez; Pan, Li; Andaluz, Hillary; Wendt, Michael K.; Iliuk, Anton B.; Tao, W. Andy

    2017-01-01

    The state of protein phosphorylation can be a key determinant of cellular physiology such as early-stage cancer, but the development of phosphoproteins in biofluids for disease diagnosis remains elusive. Here we demonstrate a strategy to isolate and identify phosphoproteins in extracellular vesicles (EVs) from human plasma as potential markers to differentiate disease from healthy states. We identified close to 10,000 unique phosphopeptides in EVs isolated from small volumes of plasma samples. Using label-free quantitative phosphoproteomics, we identified 144 phosphoproteins in plasma EVs that are significantly higher in patients diagnosed with breast cancer compared with healthy controls. Several biomarkers were validated in individual patients using paralleled reaction monitoring for targeted quantitation. This study demonstrates that the development of phosphoproteins in plasma EV as disease biomarkers is highly feasible and may transform cancer screening and monitoring. PMID:28270605

  19. Phosphoproteins in extracellular vesicles as candidate markers for breast cancer.

    PubMed

    Chen, I-Hsuan; Xue, Liang; Hsu, Chuan-Chih; Paez, Juan Sebastian Paez; Pan, Li; Andaluz, Hillary; Wendt, Michael K; Iliuk, Anton B; Zhu, Jian-Kang; Tao, W Andy

    2017-03-21

    The state of protein phosphorylation can be a key determinant of cellular physiology such as early-stage cancer, but the development of phosphoproteins in biofluids for disease diagnosis remains elusive. Here we demonstrate a strategy to isolate and identify phosphoproteins in extracellular vesicles (EVs) from human plasma as potential markers to differentiate disease from healthy states. We identified close to 10,000 unique phosphopeptides in EVs isolated from small volumes of plasma samples. Using label-free quantitative phosphoproteomics, we identified 144 phosphoproteins in plasma EVs that are significantly higher in patients diagnosed with breast cancer compared with healthy controls. Several biomarkers were validated in individual patients using paralleled reaction monitoring for targeted quantitation. This study demonstrates that the development of phosphoproteins in plasma EV as disease biomarkers is highly feasible and may transform cancer screening and monitoring.

  20. A validated HPLC-MS/MS assay for quantifying unstable pharmacologically active metabolites of clopidogrel in human plasma: application to a clinical pharmacokinetic study.

    PubMed

    Furlong, Michael T; Savant, Ishani; Yuan, Moucun; Scott, Laura; Mylott, William; Mariannino, Thomas; Kadiyala, Pathanjali; Roongta, Vikram; Arnold, Mark E

    2013-05-01

    Clopidogrel is prescribed for the treatment of Acute Coronary Syndrome and recent myocardial infarction, recent stroke, or established peripheral arterial disease. A sensitive and reliable high performance liquid chromatography-tandem mass spectrometry (HPLC-MS/MS) assay was developed and validated to enable reliable quantification of four diastereomeric and chemically reactive thiol metabolites, two of which are pharmacologically active, in human plasma. The metabolites were stabilized by alkylation of their reactive thiol moieties with 2-bromo-3'-methoxyacetophenone (MPB). Following organic solvent mediated-protein precipitation in a 96-well plate format, chromatographic separation was achieved by gradient elution on an Ascentis Express RP-amide column. Chromatographic conditions were optimized to ensure separation of the four derivatized active metabolites. Derivatized metabolites and stable isotope-labeled internal standards were detected by positive ion electrospray tandem mass spectrometry. The HPLC-MS/MS assay was validated over concentration ranges of 0.125-125 ng/mL for metabolites H1-H3 and 0.101-101 ng/mL for H4. Intra- and inter-assay precision values for replicate quality control samples were within 14.3% for all analytes during the assay validation. Mean quality control accuracy values were within ±6.3% of nominal values for all analytes. Assay recoveries were high (>79%). The four derivatized analytes were stable in human blood for at least 2 h at room temperature and on ice. The analytes were also stable in human plasma for at least 25 h at room temperature, 372 days at -20 °C and -70 °C, and following at least five freeze-thaw cycles. The validated assay was successfully applied to the quantification of all four thiol metabolites in human plasma in support of a human pharmacokinetic study. Copyright © 2013 Elsevier B.V. All rights reserved.

  1. Development and validation of sensitive LC/MS/MS method for quantitative bioanalysis of levonorgestrel in rat plasma and application to pharmacokinetics study.

    PubMed

    Ananthula, Suryatheja; Janagam, Dileep R; Jamalapuram, Seshulatha; Johnson, James R; Mandrell, Timothy D; Lowe, Tao L

    2015-10-15

    Rapid, sensitive, selective and accurate LC/MS/MS method was developed for quantitative determination of levonorgestrel (LNG) in rat plasma and further validated for specificity, linearity, accuracy, precision, sensitivity, matrix effect, recovery efficiency and stability. Liquid-liquid extraction procedure using hexane:ethyl acetate mixture at 80:20 v:v ratio was employed to efficiently extract LNG from rat plasma. Reversed phase Luna column C18(2) (50×2.0mm i.d., 3μM) installed on a AB SCIEX Triple Quad™ 4500 LC/MS/MS system was used to perform chromatographic separation. LNG was identified within 2min with high specificity. Linear calibration curve was drawn within 0.5-50ng·mL(-1) concentration range. The developed method was validated for intra-day and inter-day accuracy and precision whose values fell in the acceptable limits. Matrix effect was found to be minimal. Recovery efficiency at three quality control (QC) concentrations 0.5 (low), 5 (medium) and 50 (high) ng·mL(-1) was found to be >90%. Stability of LNG at various stages of experiment including storage, extraction and analysis was evaluated using QC samples, and the results showed that LNG was stable at all the conditions. This validated method was successfully used to study the pharmacokinetics of LNG in rats after SubQ injection, providing its applicability in relevant preclinical studies. Copyright © 2015 Elsevier B.V. All rights reserved.

  2. Determination of metoprolol enantiomers in human plasma and saliva samples utilizing microextraction by packed sorbent and liquid chromatography-tandem mass spectrometry.

    PubMed

    Elmongy, Hatem; Ahmed, Hytham; Wahbi, Abdel-Aziz; Amini, Ahmad; Colmsjö, Anders; Abdel-Rehim, Mohamed

    2016-08-01

    A sensitive, accurate and reliable bioanalytical method for the enantioselective determination of metoprolol in plasma and saliva samples utilizing liquid chromatography-electrospray ionization tandem mass spectrometry was developed and validated. Human plasma and saliva samples were pretreated by microextraction by packed sorbent (MEPS) prior to analysis. A new MEPS syringe form with two inputs was used. Metoprolol enantiomers and internal standard pentycaine (IS) were eluted from MEPS sorbent using isopropanol after removal of matrix interferences using aliquots of 5% methanol in water. Complete separation of metoprolol enantiomers was achieved on a Cellulose-SB column (150 × 4.6 mm, 5 μm) using isocratic elution with mobile phase 0.1% ammonium hydroxide in hexane-isopropanol (80:20, v/v) with a flow rate of 0.8 mL/min. A post-column solvent-assisted ionization was applied to enhance metoprolol ionization signal in positive mode monitoring (+ES) using 0.5% formic acid in isopropanol at a flow rate of 0.2 mL/min. The total chromatographic run time was 10 min for each injection. The detection of metoprolol in plasma and saliva samples was performed using triple quadrupole tandem mass spectrometer in +ES under the following mass transitions: m/z 268.08 → 72.09 for metoprolol and m/z 303.3 → 154.3 for IS. The linearity range was 2.5-500 ng/mL for both R- and S-metoprolol in plasma and saliva. The limits of detection and quantitation for both enantiomers were 0.5 and 2.5 ng/mL respectively, in both matrices (plasma and saliva). The intra- and inter-day precisions were presented in terms of RSD values for replicate analysis of quality control samples and were <5%; the accuracy of determinations varied from 96 to 99%. The method was able to determine the therapeutic levels of metoprolol enantiomers in both human plasma and saliva samples successfully, which can aid in therapeutic drug monitoring in clinical laboratories. Copyright © 2016 John Wiley & Sons, Ltd. Copyright © 2016 John Wiley & Sons, Ltd.

  3. Development and validation of an HPLC–MS/MS method to determine clopidogrel in human plasma

    PubMed Central

    Liu, Gangyi; Dong, Chunxia; Shen, Weiwei; Lu, Xiaopei; Zhang, Mengqi; Gui, Yuzhou; Zhou, Qinyi; Yu, Chen

    2015-01-01

    A quantitative method for clopidogrel using online-SPE tandem LC–MS/MS was developed and fully validated according to the well-established FDA guidelines. The method achieves adequate sensitivity for pharmacokinetic studies, with lower limit of quantifications (LLOQs) as low as 10 pg/mL. Chromatographic separations were performed on reversed phase columns Kromasil Eternity-2.5-C18-UHPLC for both methods. Positive electrospray ionization in multiple reaction monitoring (MRM) mode was employed for signal detection and a deuterated analogue (clopidogrel-d4) was used as internal standard (IS). Adjustments in sample preparation, including introduction of an online-SPE system proved to be the most effective method to solve the analyte back-conversion in clinical samples. Pooled clinical samples (two levels) were prepared and successfully used as real-sample quality control (QC) in the validation of back-conversion testing under different conditions. The result showed that the real samples were stable in room temperature for 24 h. Linearity, precision, extraction recovery, matrix effect on spiked QC samples and stability tests on both spiked QCs and real sample QCs stored in different conditions met the acceptance criteria. This online-SPE method was successfully applied to a bioequivalence study of 75 mg single dose clopidogrel tablets in 48 healthy male subjects. PMID:26904399

  4. Total Arsenic, Cadmium, and Lead Determination in Brazilian Rice Samples Using ICP-MS

    PubMed Central

    Buzzo, Márcia Liane; de Arauz, Luciana Juncioni; Carvalho, Maria de Fátima Henriques; Arakaki, Edna Emy Kumagai; Matsuzaki, Richard; Tiglea, Paulo

    2016-01-01

    This study is aimed at investigating a suitable method for rice sample preparation as well as validating and applying the method for monitoring the concentration of total arsenic, cadmium, and lead in rice by using Inductively Coupled Plasma Mass Spectrometry (ICP-MS). Various rice sample preparation procedures were evaluated. The analytical method was validated by measuring several parameters including limit of detection (LOD), limit of quantification (LOQ), linearity, relative bias, and repeatability. Regarding the sample preparation, recoveries of spiked samples were within the acceptable range from 89.3 to 98.2% for muffle furnace, 94.2 to 103.3% for heating block, 81.0 to 115.0% for hot plate, and 92.8 to 108.2% for microwave. Validation parameters showed that the method fits for its purpose, being the total arsenic, cadmium, and lead within the Brazilian Legislation limits. The method was applied for analyzing 37 rice samples (including polished, brown, and parboiled), consumed by the Brazilian population. The total arsenic, cadmium, and lead contents were lower than the established legislative values, except for total arsenic in one brown rice sample. This study indicated the need to establish monitoring programs for emphasizing the study on this type of cereal, aiming at promoting the Public Health. PMID:27766178

  5. A single method for detecting 11 organophosphate pesticides in human plasma and breastmilk using GC-FPD

    PubMed Central

    Naksen, Warangkana; Prapamontol, Tippawan; Mangklabruks, Ampica; Chantara, Somporn; Thavornyutikarn, Prasak; Robson, Mark G.; Ryan, P. Barry; Barr, Dana Boyd; Panuwet, Parinya

    2016-01-01

    Organophosphate (OP) pesticides are widely used for crop protection in many countries including Thailand. Aside from causing environmental contamination, they affect human health especially by over-stimulating of the neurotransmission system. OP pesticides, as with other non-persistent pesticides, degrade quickly in the environment as well as are metabolized quite rapidly in humans. Assessing human exposures to these compounds requires analytical methods that are sensitive, robust, and most importantly, suitable for specific laboratory settings. The aim of this study was to develop and validate an analytical method for measuring 11 OP pesticide residues in human plasma and breast milk. Analytes in both plasma and breast milk samples were extracted with acetone and methylene chloride, cleaned-up using aminopropyl solid phase extraction cartridges, and analyzed by gas chromatography with flame photometric detection. The optimized method exhibited good linearity, with the coefficients of determination of 0.996–0.999 and <7% error about the slope. Extraction recoveries from spiked plasma and breast milk samples at low and medium concentrations (0.8–5.0 and 1.6–10 ng mL−1, respectively) ranged from 59.4 % (ethion) to 94.0 % (chlorpyrifos). Intra-batch and inter-batch precisions ranged from 2.3–18.9% and 5.8–19.5%, respectively. Method detection limits of plasma and breast milk ranged from 0.18–1.36 and 0.09–2.66 ng mL−1, respectively. We analyzed 63 plasma and 30 breastmilk samples collected from farmworkers in Chiang Mai Province to determine the suitability of this method for occupational exposure assessment. Of the 11 pesticides measured, seven were detected in plasma samples and five were detected in breast milk samples. Mass spectrometry was used to confirm results. Overall, this method is rapid and reliable. It offers the laboratories with limited access to mass spectrometry a capacity to investigate levels OP pesticides in plasma and breastmilk in those occupationally exposed for health risk assessment. PMID:27232054

  6. Liquid chromatography-tandem mass spectrometric assay for the simultaneous determination of the irreversible BTK inhibitor ibrutinib and its dihydrodiol-metabolite in plasma and its application in mouse pharmacokinetic studies.

    PubMed

    Rood, Johannes J M; van Hoppe, Stephanie; Schinkel, Alfred H; Schellens, Jan H M; Beijnen, Jos H; Sparidans, Rolf W

    2016-01-25

    A validated simple, fast and sensitive bio-analytical assay for ibrutinib and its dihydrodiol metabolite in human and mouse plasma was set up. Sample preparation was performed by protein precipitation, and addition of the respective deuterated internal standards, followed by LC-MS/MS analysis. Separation was performed on a 3.5 μm particle-size, bridged ethylene hybrid column with gradient elution by 0.1% v/v formic acid and acetonitrile. The full eluate was transferred to an electrospray interface in positive ionization mode, and subsequently analyzed by a triple quadrupole mass spectrometer by selected reaction monitoring. The assay was validated in a 5-5000 ng/ml calibration range. Both ibrutinib and dihydrodiol-ibrutinib were deemed stable under refrigerated or frozen storage conditions. At room temperature, ibrutinib showed a not earlier described instability, and revealed rapid degradation at 37 °C. Finally, the assay was used for a pharmacokinetic study of plasma levels in treated FVB mice. Copyright © 2015 Elsevier B.V. All rights reserved.

  7. One mouse, one pharmacokinetic profile: quantitative whole blood serial sampling for biotherapeutics.

    PubMed

    Joyce, Alison P; Wang, Mengmeng; Lawrence-Henderson, Rosemary; Filliettaz, Cynthia; Leung, Sheldon S; Xu, Xin; O'Hara, Denise M

    2014-07-01

    The purpose of this study was to validate the approach of serial sampling from one mouse through ligand binding assay (LBA) quantification of dosed biotherapeutic in diluted whole blood to derive a pharmacokinetic (PK) profile. This investigation compared PK parameters obtained using serial and composite sampling methods following administration of human IgG monoclonal antibody. The serial sampling technique was established by collecting 10 μL of blood via tail vein at each time point following drug administration. Blood was immediately diluted into buffer followed by analyte quantitation using Gyrolab to derive plasma concentrations. Additional studies were conducted to understand matrix and sampling site effects on drug concentrations. The drug concentration profiles, irrespective of biological matrix, and PK parameters using both sampling methods were not significantly different. There were no sampling site effects on drug concentration measurements except that concentrations were slightly lower in sodium citrated plasma than other matrices. We recommend the application of mouse serial sampling, particularly with limiting drug supply or specialized animal models. Overall the efficiencies gained by serial sampling were 40-80% savings in study cost, animal usage, study length and drug conservation while inter-subject variability across PK parameters was less than 30%.

  8. Determination of vigabatrin in human plasma and urine by high-performance liquid chromatography with UV-Vis detection.

    PubMed

    Cetin, Sevil Müge; Atmaca, Sedef

    2004-03-26

    A simple and reliable high-performance liquid chromatographic (HPLC) method with UV-Vis detection has been developed and validated for the determination of vigabatrin (VG) in human plasma and urine. The samples were pre-column derivatizated with 1,2-naphthoquinone-4-sulphonic acid sodium salt (NQS). A good chromatographic separation was achieved on a C18 column with a mobile phase consisting of acetonitrile and 10 mM orthophosphoric acid (pH 2.5) gradient elution. Tranexamic acid was used as an internal standard (I.S.). The method was linear over the concentration range of 0.8-30.0 microg/ml for both samples. The method is precise (relative standard deviation (R.S.D.) <9.13%) and accurate (relative mean error (RME) <-8.75%); analytical recoveries were 81.07% for plasma and 83.05% for urine. The assay was applied to pharmacokinetic study in a healthy volunteer after a single oral administration of 1 g of vigabatrin.

  9. High wavenumber Raman spectroscopic characterization of normal and oral cancer using blood plasma

    NASA Astrophysics Data System (ADS)

    Pachaiappan, Rekha; Prakasarao, Aruna; Suresh Kumar, Murugesan; Singaravelu, Ganesan

    2017-02-01

    Blood plasma possesses the biomolecules released from cells/tissues after metabolism and reflects the pathological conditions of the subjects. The analysis of biofluids for disease diagnosis becomes very attractive in the diagnosis of cancers due to the ease in the collection of samples, easy to transport, multiple sampling for regular screening of the disease and being less invasive to the patients. Hence, the intention of this study was to apply near-infrared (NIR) Raman spectroscopy in the high wavenumber (HW) region (2500-3400 cm-1) for the diagnosis of oral malignancy using blood plasma. From the Raman spectra it is observed that the biomolecules protein and lipid played a major role in the discrimination between groups. The diagnostic algorithms based on principal components analysis coupled with linear discriminant analysis (PCA-LDA) with the leave-one-patient-out cross-validation method on HW Raman spectra yielded a promising results in the identification of oral malignancy. The details of results will be discussed.

  10. Circular RNA hsa_circ_0000745 may serve as a diagnostic marker for gastric cancer.

    PubMed

    Huang, Mei; He, Yi-Ren; Liang, Li-Chuan; Huang, Qiang; Zhu, Zhi-Qiang

    2017-09-14

    To determine whether circular RNAs (circRNAs) are involved in pathological processes of gastric cancer (GC). Three circRNAs with differential expression in GC and colorectal cancer were randomly selected for validation by quantitative reverse transcription-polymerase chain reaction (qRT-PCR), using 20 pairs of gastric tissues and normal tissues. Based on the predicted circRNA-miRNA network, we then focused on hsa_circ_0000745, which was found to be down-regulated in 20 GC tissues compared with normal tissues. The hsa_circ_0000745 levels were further analyzed by qRT-PCR in 60 GC tissues and paired adjacent non-tumor tissues, as well as 60 plasma samples from GC patients and 60 plasma samples from healthy controls. The associations between the levels of hsa_circ_0000745 and the clinicopathological features of GC patients were statistically assessed. A receiver operating characteristic (ROC) curve was used to evaluate the diagnostic value of hsa_circ_0000745 in GC. Hsa_circ_0000745 was down-regulated in GC tissues vs non-tumorous tissues ( P < 0.001) and in plasma samples from patients with GC vs healthy controls ( P < 0.001). The expression level of hsa_circ_0000745 in GC tissues correlated with tumor differentiation, while the expression level in plasma correlated with tumor-node-metastasis stage. The area under the ROC curve (AUC) of hsa_circ_0000745 in plasma was 0.683, suggesting good diagnostic value. Plasma hsa_circ_0000745 level combined with carcinoembryogenic antigen (CEA) level increased the AUC to 0.775. Hsa_circ_0000745 plays an important role in GC and its expression level in plasma in combination with CEA level is a promising diagnostic marker for this malignancy.

  11. A Novel LC-MS-MS Method With an Effective Antioxidant for the Determination of Edaravone, a Free-Radical Scavenger in Dog Plasma and its Application to a Pharmacokinetic Study.

    PubMed

    Shao, Feng; Hu, Xiao-Ling; Liu, Xin; Shan, Mang-Ting

    2017-07-01

    The objective of this study was to investigate the stability of edaravone in dog plasma by using an added antioxidant stabilizer, with an ultimate goal of developing and validating a sensitive, reliable and robust LC-MS-MS method for determination of edaravone in plasma samples. Edaravone was unstable in plasma, but it presented a good stability performance in the plasma with sodium metabisulfite (SMB), an effective antioxidant. The blood sample was collected in the heparinized eppendorf tube containing SMB and plasma sample was deproteinized using acetonitrile containing 20 ng/mL of phenacetin (Internal standard). The chromatographic separation was performed on a Zorbax Extend-C18 analytical column (2.1 mm × 150 mm I.D., particle size 3.5 µm, Agilent Technologies, USA). The mobile phase consisted of 0.1% formic acid in water (v/v) and methanol, and gradient elution was used. The analyte detection was performed on a triple quadrupole tandem mass spectrometer equipped with positive-ion electrospray ionization by multiple reaction ion monitoring mode of the transitions at m/z [M + H]+ 175.1 → 77.1 for edaravone, and m/z [M + H]+ 180.2 → 110.0 for phenacetin. The linearity of this method was within the concentration range of 10-1000 ng/mL for edaravone in dog plasma. The lower limit of quantification was 10 ng/mL. The relative standard deviations of intra- and inter-precision were <10%. This method was successfully employed in the pharmacokinetics evaluation of edaravone in beagle dogs after intravenous administration. © The Author 2017. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.

  12. Determinination of plasma osmolality and agreement between measured and calculated values in healthy adult Hispaniolan Amazon parrots (Amazona ventralis).

    PubMed

    Acierno, Mark J; Mitchell, Mark A; Freeman, Diana M; Schuster, Patricia J; Guzman, David Sanchez-Migallon; Tully, Thomas N

    2009-09-01

    To determine plasma osmolality in healthy adult Hispaniolan Amazon parrots (Amazona ventralis) and validate osmolality equations in these parrots. 20 healthy adult Hispaniolan Amazon parrots. A blood sample (0.5 mL) was collected from the right jugular vein of each parrot and placed into a lithium heparin microtainer tube. Samples were centrifuged, and plasma was harvested and frozen at -30 degrees C. Samples were thawed, and plasma osmolality was measured in duplicate with a freezing-point depression osmometer. The mean value was calculated for the 2 osmolality measurements. Plasma osmolality values were normally distributed, with a mean +/- SD of 326.0 +/- 6.878 mOsm/kg. The equations (2 x [Na(+) + K(+)]) + (glucose/18), which resulted in bias of 2.3333 mOsm/kg and limits of agreement of -7.0940 to 11.7606 mOsm/kg, and (2 x [Na(+) + K(+)]) + (uric acid concentration/16.8) + (glucose concentration/18), which resulted in bias of 5.8117 mOsm/kg and limits of agreement of -14.6640 to 3.0406 mOsm/kg, yielded calculated values that were in good agreement with the measured osmolality. IV administration of large amounts of hypotonic fluids can have catastrophic consequences. Osmolality of the plasma from parrots in this study was significantly higher than that of commercially available prepackaged fluids. Therefore, such fluids should be used with caution in Hispaniolan Amazon parrots as well as other psittacines. Additional studies are needed to determine whether the estimation of osmolality has the same clinical value in psittacines as it does in other animals.

  13. High-performance liquid chromatography-tandem mass spectrometry for simultaneous determination of raltegravir, dolutegravir and elvitegravir concentrations in human plasma and cerebrospinal fluid samples.

    PubMed

    Tsuchiya, Kiyoto; Ohuchi, Mayu; Yamane, Naoe; Aikawa, Hiroaki; Gatanaga, Hiroyuki; Oka, Shinichi; Hamada, Akinobu

    2018-02-01

    A simple sample treatment procedure and sensitive liquid chromatography-tandem mass spectrometry method were developed for the simultaneous quantification of the concentrations of human immunodeficiency virus-1 integrase strand transfer inhibitors - raltegravir, dolutegravir and elvitegravir - in human plasma and cerebrospinal fluid (CSF). Plasma and CSF samples (20 μL each) were deproteinized with acetonitrile. Raltegravir-d 3 was used as the internal standard. Chromatographic separation was achieved on an XBridge C 18 column (50 × 2.1 mm i.d., particle size 3.5 μm) using acetonitrile-water (7:3, v/v) containing 0.1% formic acid as the mobile phase at a flow rate of 0.2 mL/min. The run time was 5 min. Calibration curves for all three drugs were linear in the range 5-1500 ng/mL for plasma and 1-200 ng/mL for CSF. The intra- and inter-day precision and accuracy of all three drugs in plasma were coefficient of variation (CV) <12.9% and 100.0 ± 12.2%, respectively, while those in CSF were CV <12.3% and 100.0 ± 7.9%, respectively. Successful validation under the same LC-MS/MS conditions for both plasma and CSF indicates this analytical method is useful for monitoring the levels of these integrase strand transfer inhibitors in the management of treatment of HIV-1 carriers. Copyright © 2017 John Wiley & Sons, Ltd.

  14. Sample preparation and liquid chromatography-tandem mass spectrometry for multiple steroids in mammalian and avian circulation.

    PubMed

    Koren, Lee; Ng, Ella S M; Soma, Kiran K; Wynne-Edwards, Katherine E

    2012-01-01

    Blood samples from wild mammals and birds are often limited in volume, allowing researchers to quantify only one or two steroids from a single sample by immunoassays. In addition, wildlife serum or plasma samples are often lipemic, necessitating stringent sample preparation. Here, we validated sample preparation for simultaneous liquid chromatography--tandem mass spectrometry (LC-MS/MS) quantitation of cortisol, corticosterone, 11-deoxycortisol, dehydroepiandrosterone (DHEA), 17β-estradiol, progesterone, 17α-hydroxyprogesterone and testosterone from diverse mammalian (7 species) and avian (5 species) samples. Using 100 µL of serum or plasma, we quantified (signal-to-noise (S/N) ratio ≥ 10) 4-7 steroids depending on the species and sample, without derivatization. Steroids were extracted from serum or plasma using automated solid-phase extraction where samples were loaded onto C18 columns, washed with water and hexane, and then eluted with ethyl acetate. Quantitation by LC-MS/MS was done in positive ion, multiple reaction-monitoring (MRM) mode with an atmospheric pressure chemical ionization (APCI) source and heated nebulizer (500°C). Deuterated steroids served as internal standards and run time was 15 minutes. Extraction recoveries were 87-101% for the 8 analytes, and all intra- and inter-run CVs were ≤ 8.25%. This quantitation method yields good recoveries with variable lipid-content samples, avoids antibody cross-reactivity issues, and delivers results for multiple steroids. Thus, this method can enrich datasets by providing simultaneous quantitation of multiple steroids, and allow researchers to reimagine the hypotheses that could be tested with their volume-limited, lipemic, wildlife samples.

  15. Measuring factor IX activity of nonacog beta pegol with commercially available one-stage clotting and chromogenic assay kits: a two-center study.

    PubMed

    Bowyer, A E; Hillarp, A; Ezban, M; Persson, P; Kitchen, S

    2016-07-01

    Essentials Validated assays are required to precisely measure factor IX (FIX) activity in FIX products. N9-GP and two other FIX products were assessed in various coagulation assay systems at two sites. Large variations in FIX activity measurements were observed for N9-GP using some assays. One-stage and chromogenic assays accurately measuring FIX activity for N9-GP were identified. Background Measurement of factor IX activity (FIX:C) with activated partial thromboplastin time-based one-stage clotting assays is associated with a large degree of interlaboratory variation in samples containing glycoPEGylated recombinant FIX (rFIX), i.e. nonacog beta pegol (N9-GP). Validation and qualification of specific assays and conditions are necessary for the accurate assessment of FIX:C in samples containing N9-GP. Objectives To assess the accuracy of various one-stage clotting and chromogenic assays for measuring FIX:C in samples containing N9-GP as compared with samples containing rFIX or plasma-derived FIX (pdFIX) across two laboratory sites. Methods FIX:C, in severe hemophilia B plasma spiked with a range of concentrations (from very low, i.e. 0.03 IU mL(-1) , to high, i.e. 0.90 IU mL(-1) ) of N9-GP, rFIX (BeneFIX), and pdFIX (Mononine), was determined at two laboratory sites with 10 commercially available one-stage clotting assays and two chromogenic FIX:C assays. Assays were performed with a plasma calibrator and different analyzers. Results A high degree of variation in FIX:C measurement was observed for one-stage clotting assays for N9-GP as compared with rFIX or pdFIX. Acceptable N9-GP recovery was observed in the low-concentration to high-concentration samples tested with one-stage clotting assays using SynthAFax or DG Synth, or with chromogenic FIX:C assays. Similar patterns of FIX:C measurement were observed at both laboratory sites, with minor differences probably being attributable to the use of different analyzers. Conclusions These results suggest that, of the reagents tested, FIX:C in N9-GP-containing plasma samples can be most accurately measured with one-stage clotting assays using SynthAFax or DG Synth, or with chromogenic FIX:C assays. © 2016 International Society on Thrombosis and Haemostasis.

  16. Could Digital PCR Be an Alternative as a Non-Invasive Prenatal Test for Trisomy 21: A Proof of Concept Study

    PubMed Central

    El Khattabi, Laïla Allach; Rouillac-Le Sciellour, Christelle; Le Tessier, Dominique; Luscan, Armelle; Coustier, Audrey; Porcher, Raphael; Bhouri, Rakia; Nectoux, Juliette; Sérazin, Valérie; Quibel, Thibaut; Mandelbrot, Laurent; Tsatsaris, Vassilis

    2016-01-01

    Objective NIPT for fetal aneuploidy by digital PCR has been hampered by the large number of PCR reactions needed to meet statistical requirements, preventing clinical application. Here, we designed an octoplex droplet digital PCR (ddPCR) assay which allows increasing the number of available targets and thus overcomes statistical obstacles. Method After technical optimization of the multiplex PCR on mixtures of trisomic and euploid DNA, we performed a validation study on samples of plasma DNA from 213 pregnant women. Molecular counting of circulating cell-free DNA was performed using a mix of hydrolysis probes targeting chromosome 21 and a reference chromosome. Results The results of our validation experiments showed that ddPCR detected trisomy 21 even when the sample’s trisomic DNA content is as low as 5%. In a validation study of plasma samples from 213 pregnant women, ddPCR discriminated clearly between the trisomy 21 and the euploidy groups. Conclusion Our results demonstrate that digital PCR can meet the requirements for non-invasive prenatal testing of trisomy 21. This approach is technically simple, relatively cheap, easy to implement in a diagnostic setting and compatible with ethical concerns regarding access to nucleotide sequence information. These advantages make it a potential technique of choice for population-wide screening for trisomy 21 in pregnant women. PMID:27167625

  17. MicroRNA-6826 and -6875 in plasma are valuable non‑invasive biomarkers that predict the efficacy of vaccine treatment against metastatic colorectal cancer.

    PubMed

    Kijima, Taiki; Hazama, Shoichi; Tsunedomi, Ryouichi; Tanaka, Hironori; Takenouchi, Hiroko; Kanekiyo, Shinsuke; Inoue, Yuka; Nakashima, Masao; Iida, Michihisa; Sakamoto, Kazuhiko; Suzuki, Nobuaki; Takeda, Shigeru; Ueno, Tomio; Yamamoto, Shigeru; Yoshino, Shigefumi; Okuno, Kiyotaka; Nagano, Hiroaki

    2017-01-01

    Various vaccine treatments against metastatic colorectal cancer have been developed and applied. However, to improve the efficacy of immunotherapy, biomarkers that can predict the effects are needed. It has been reported that various microRNAs (miRNAs) in peripheral blood may be useful as non-invasive biomarkers. In this study, miRNAs influencing the efficacy of vaccine treatment were screened for in a microarray analysis of 13 plasma samples that were obtained from patients prior to vaccine treatment. To validate the screening results, real-time RT-PCR was performed using 93 plasma samples obtained from patients prior to vaccine treatment. Four candidate miRNAs were selected according to the results of the comprehensive analysis of miRNA expression, which were ranked using the Fisher criterion and the absolute value of the log2 ratio in the screening analysis. The validation analysis showed that in the HLA-A*2402‑matched patient group (vaccine-treated group), patients with a high expression of plasma miR-6826 had a poorer prognosis than those with a low expression (P=0.048). In contrast, in the HLA-A*2402-unmatched patient group (control group), there was no difference between the patients with high or low plasma miR-6826 expression (P=0.168). Similar results were obtained in the analysis of miR-6875 (P=0.029 and P=0.754, respectively). Moreover, multivariate analysis of the Cox regression model indicated that the expression of miR-6826 was the most significant predictor for overall survival (P=0.003, hazard ratio, 3.670). In conclusion, plasma miR-6826 and miR-6875 may be predictive biomarkers for a poor response to vaccine treatment. Although further clarification is needed regarding the functions of miR-6826 and miR-6875 and their relationship to immune‑related molecules, plasma miR-6826 and miR-6875 may be useful negative biomarkers for predicting the efficacy of vaccine treatment.

  18. Limited sampling strategy for determining metformin area under the plasma concentration–time curve

    PubMed Central

    Santoro, Ana Beatriz; Stage, Tore Bjerregaard; Struchiner, Claudio José; Christensen, Mette Marie Hougaard; Brosen, Kim

    2016-01-01

    Aim The aim was to develop and validate limited sampling strategy (LSS) models to predict the area under the plasma concentration–time curve (AUC) for metformin. Methods Metformin plasma concentrations (n = 627) at 0–24 h after a single 500 mg dose were used for LSS development, based on all subsets linear regression analysis. The LSS‐derived AUC(0,24 h) was compared with the parameter ‘best estimate’ obtained by non‐compartmental analysis using all plasma concentration data points. Correlation between the LSS‐derived and the best estimated AUC(0,24 h) (r 2), bias and precision of the LSS estimates were quantified. The LSS models were validated in independent cohorts. Results A two‐point (3 h and 10 h) regression equation with no intercept estimated accurately the individual AUC(0,24 h) in the development cohort: r 2 = 0.927, bias (mean, 95% CI) –0.5, −2.7–1.8% and precision 6.3, 4.9–7.7%. The accuracy of the two point LSS model was verified in study cohorts of individuals receiving single 500 or 1000 mg (r 2 = –0.933–0.934) or seven 1000 mg daily doses (r 2 = 0.918), as well as using data from 16 published studies covering a wide range of metformin doses, demographics, clinical and experimental conditions (r 2 = 0.976). The LSS model reproduced previously reported results for effects of polymorphisms in OCT2 and MATE1 genes on AUC(0,24 h) and renal clearance of metformin. Conclusions The two point LSS algorithm may be used to assess the systemic exposure to metformin under diverse conditions, with reduced costs of sampling and analysis, and saving time for both subjects and investigators. PMID:27324407

  19. Use of Dried Blood Spots to Elucidate Full-Length Transmitted/Founder HIV-1 Genomes

    PubMed Central

    Salazar-Gonzalez, Jesus F.; Salazar, Maria G.; Tully, Damien C.; Ogilvie, Colin B.; Learn, Gerald H.; Allen, Todd M.; Heath, Sonya L.; Goepfert, Paul; Bar, Katharine J.

    2016-01-01

    Background Identification of HIV-1 genomes responsible for establishing clinical infection in newly infected individuals is fundamental to prevention and pathogenesis research. Processing, storage, and transportation of the clinical samples required to perform these virologic assays in resource-limited settings requires challenging venipuncture and cold chain logistics. Here, we validate the use of dried-blood spots (DBS) as a simple and convenient alternative to collecting and storing frozen plasma. Methods We performed parallel nucleic acid extraction, single genome amplification (SGA), next generation sequencing (NGS), and phylogenetic analyses on plasma and DBS. Results We demonstrated the capacity to extract viral RNA from DBS and perform SGA to infer the complete nucleotide sequence of the transmitted/founder (TF) HIV-1 envelope gene and full-length genome in two acutely infected individuals. Using both SGA and NGS methodologies, we showed that sequences generated from DBS and plasma display comparable phylogenetic patterns in both acute and chronic infection. SGA was successful on samples with a range of plasma viremia, including samples as low as 1,700 copies/ml and an estimated ∼50 viral copies per blood spot. Further, we demonstrated reproducible efficiency in gp160 env sequencing in DBS stored at ambient temperature for up to three weeks or at -20°C for up to five months. Conclusions These findings support the use of DBS as a practical and cost-effective alternative to frozen plasma for clinical trials and translational research conducted in resource-limited settings. PMID:27819061

  20. Standardized protocols for quality control of MRM-based plasma proteomic workflows.

    PubMed

    Percy, Andrew J; Chambers, Andrew G; Smith, Derek S; Borchers, Christoph H

    2013-01-04

    Mass spectrometry (MS)-based proteomics is rapidly emerging as a viable technology for the identification and quantitation of biological samples, such as human plasma--the most complex yet commonly employed biofluid in clinical analyses. The transition from a qualitative to quantitative science is required if proteomics is going to successfully make the transition to a clinically useful technique. MS, however, has been criticized for a lack of reproducibility and interlaboratory transferability. Currently, the MS and plasma proteomics communities lack standardized protocols and reagents to ensure that high-quality quantitative data can be accurately and precisely reproduced by laboratories across the world using different MS technologies. Toward addressing this issue, we have developed standard protocols for multiple reaction monitoring (MRM)-based assays with customized isotopically labeled internal standards for quality control of the sample preparation workflow and the MS platform in quantitative plasma proteomic analyses. The development of reference standards and their application to a single MS platform is discussed herein, along with the results from intralaboratory tests. The tests highlighted the importance of the reference standards in assessing the efficiency and reproducibility of the entire bottom-up proteomic workflow and revealed errors related to the sample preparation and performance quality and deficits of the MS and LC systems. Such evaluations are necessary if MRM-based quantitative plasma proteomics is to be used in verifying and validating putative disease biomarkers across different research laboratories and eventually in clinical laboratories.

  1. Pharmacokinetic Modeling of Intranasal Scopolamine in Plasma Saliva and Urine

    NASA Technical Reports Server (NTRS)

    Wu, L.; Tam, V. H.; Chow, D. S. L.; Putcha, L.

    2015-01-01

    An intranasal gel dosage formulation of scopolamine (INSCOP) was developed for the treatment of Space Motion Sickness (SMS). The bioavailability and pharmacokinetics (PK) were evaluated under IND (Investigational New Drug) guidelines. The aim of the project was to develop a PK model that can predict the relationships among plasma, saliva and urinary scopolamine concentrations using data collected from the IND clinical trial protocol with INSCOP. Twelve healthy human subjects were administered at three dose levels (0.1, 0.2 and 0.4 mg) of INSCOP. Serial blood, saliva and urine samples were collected between 5 min to 24 h after dosing and scopolamine concentrations were measured by using a validated LC-MS-MS assay. PK compartmental models, using actual dosing and sampling time, were established using Phoenix (version 1.2). Model selection was based on a likelihood ratio test on the difference of criteria (-2LL (i.e. log-likelihood ratio test)) and comparison of the quality of fit plots. The results: Predictable correlations among scopolamine concentrations in compartments of plasma, saliva and urine were established, and for the first time the model satisfactorily predicted the population and individual PK of INSCOP in plasma, saliva and urine. The model can be utilized to predict the INSCOP plasma concentration by saliva and urine data, and it will be useful for monitoring the PK of scopolamine in space and other remote environments using non-invasive sampling of saliva and/or urine.

  2. Determination of parthenolide in rat plasma by UPLC-MS/MS and its application to a pharmacokinetic study.

    PubMed

    Zhao, Ai-qin; Zhao, Ji-hong; Zhang, Shu-qing; Pan, Yong-yang; Huo, Xu-lei

    2016-02-05

    A rapid, sensitive and selective ultra-performance liquid chromatography tandem mass spectrometry (UPLC-MS/MS) method was developed and validated for the determination and pharmacokinetic investigation of parthenolide in rat plasma. Sample preparation was accomplished through a simple one-step deproteinization procedure with 0.2mL of acetonitrile containing 30ng/mL of pirfenidone (IS), and to a 0.1mL plasma sample. Plasma samples were separated by UPLC on an Acquity UPLC BEH C18 column using a mobile phase consisting of acetonitrile-0.1% formic acid in water with gradient elution. The total run time was 3.0min and the elution of parthenolide was at 1.33min. The detection was performed on a triple quadrupole tandem mass spectrometer in the multiple reaction-monitoring (MRM) mode using the respective transitions m/z 249.2→231.1 for parthenolide and m/z 186.2→92.1 for pirfenidone (IS), respectively. The calibration curve was linear over the range of 2.0-500ng/mL with a lower limit of quantitation (LLOQ) of 2.0ng/mL. Mean recovery of parthenolide in plasma was in the range of 78.2-86.6%. Intra-day and inter-day precision were both <8.3%. This method was successfully applied in pharmacokinetic study after oral and intravenous administration of parthenolide in rats. Copyright © 2015 Elsevier B.V. All rights reserved.

  3. LC-MS/MS quantification of free and Fab-bound colchicine in plasma, urine and organs following colchicine administration and colchicine-specific Fab fragments treatment in Göttingen minipigs.

    PubMed

    Fabresse, Nicolas; Allard, Julien; Sardaby, Marine; Thompson, Adrian; Clutton, R Eddie; Eddleston, Michael; Alvarez, Jean-Claude

    2017-08-15

    Clinical evaluation of a colchicine specific antigen-binding fragment (Fab) in order to treat colchicine poisoning required the development of an accurate method allowing quantification of free and Fab-bound colchicine in plasma and urine, and free colchicine in tissues, to measure colchicine redistribution after Fab administration. Three methods have been developed for this purpose, and validated in plasma, urine and liver: total colchicine was determined after denaturation of Fab by dilution in water and heating; free colchicine was separated from Fab-bound colchicine by filtration with 30KDa micro-filters; tissues were homogenized in a tissue mixer. Deuterated colchicine was used as internal standard. Samples were extracted by liquid-liquid extraction and analyzed with a LC-MS/MS. LOQ were 0.5ng/mL in plasma and urine for free and total colchicine and 5pg/mg in tissues. The methods were linear in the 0.5-100ng/mL range in plasma and urine, and 5-300pg/mg in tissues with determination coefficients>0.99. Precision and accuracy of QC samples presented a CV<9.4%. The methods require only 200μL of sample and allow a high throughput due to short analytical run (2min). These methods were successfully applied to a pig intoxicated with colchicine and treated with colchicine specific Fab fragments. Copyright © 2017 Elsevier B.V. All rights reserved.

  4. Simultaneous determination of neochlorogenic acid, chlorogenic acid, cryptochlorogenic acid and geniposide in rat plasma by UPLC-MS/MS and its application to a pharmacokinetic study after administration of Reduning injection.

    PubMed

    Wang, Yanjuan; Wen, Jing; Zheng, Weihua; Zhao, Longshan; Fu, Xiaohuan; Wang, Zhenzhong; Xiong, Zhili; Li, Famei; Xiao, Wei

    2015-01-01

    A simple, specific and sensitive ultra-performance liquid chromatography tandem mass spectrometry (UPLC-MS/MS) method was established and validated for simultaneous determination of neochlorogenic acid, chlorogenic acid, cryptochlorogenic acid and geniposide in rat plasma using puerarin as an internal standard (IS). Plasma samples were pretreated by a one-step direct protein precipitation procedure with acetonitrile after acidified using as little as 50 μL plasma. Chromatographic separation was performed on an Acquity BEH C18 column (100 × 2.1 mm, 1.7 µm) at a flow rate of 0.2 mL/min by a gradient elution, using 0.2% acetic acid-methanol as mobile phase. The detection was performed on a triple quadrupole tandem mass spectrometer by multiple reaction monitoring via electrospray ionization source with negative ion mode. Calibration curves showed good linearity (r > 0.995) over wide concentration ranges. The intra- and inter-day precisions were <15%, and the accuracy was within ±8.0%. The validated method was successfully applied to a pharmacokinetic study of the four bioactive components in rats after intravenous administration of Reduning injection. Copyright © 2014 John Wiley & Sons, Ltd.

  5. Ultra-sensitive LC-MS/MS method for the quantification of gemcitabine and its metabolite 2',2'-difluorodeoxyuridine in human plasma for a microdose clinical trial.

    PubMed

    van Nuland, M; Hillebrand, M J X; Rosing, H; Burgers, J A; Schellens, J H M; Beijnen, J H

    2018-03-20

    In microdose clinical trials a maximum of 100 μg of drug substance is administered to participants, in order to determine the pharmacokinetic properties of the agents. Measuring low plasma concentrations after administration of a microdose is challenging and requires the use of ulta-sensitive equipment. Novel liquid chromatography-mass spectrometry (LC-MS/MS) platforms can be used for quantification of low drug plasma levels. Here we describe the development and validation of an LC-MS/MS method for quantification of gemcitabine and its metabolite 2',2'-difluorodeoxyuridine (dFdU) in the low picogram per milliliter range to support a microdose trial. The validated assay ranges from 2.5-500 pg/mL for gemcitabine and 250-50,000 pg/mL for dFdU were linear, with a correlation coefficient (r 2 ) of 0.996 or better. Sample preparation with solid phase extraction provided a good and reproducible recovery. All results were within the acceptance criteria of the latest US FDA guidance and EMA guidelines. In addition, the method was successfully applied to measure plasma concentrations of gemcitabine in a patient after administration of a microdose of gemcitabine. Copyright © 2017 Elsevier B.V. All rights reserved.

  6. Simultaneous determination of phenytoin, carbamazepine, and 10,11-carbamazepine epoxide in human plasma by high-performance liquid chromatography with ultraviolet detection.

    PubMed

    Bhatti, M M; Hanson, G D; Schultz, L

    1998-03-01

    The Bioanalytical Chemistry Department at the Madison facility of Covance Laboratories, has developed and validated a simple and sensitive method for the simultaneous determination of phenytoin (PHT), carbamazepine (CBZ) and 10,11-carbamazepine epoxide (CBZ-E) in human plasma by high-performance liquid chromatography with 10,11 dihydrocarbamazepine as the internal standard. Acetonitrile was added to plasma samples containing PHT, CBZ and CBZ-E to precipitate the plasma proteins. After centrifugation, the acetonitrile supernatant was transferred to a clean tube and evaporated under N2. The dried sample extract was reconstituted in 0.4 ml of mobile phase and injected for analysis by high-performance liquid chromatography. Separation was achieved on a Spherisorb ODS2 analytical column with a mobile phase of 18:18:70 acetonitrile:methanol:potassium phosphate buffer. Detection was at 210 nm using an ultraviolet detector. The mean retention times of CBZ-E, PHT and CBZ were 5.8, 9.9 and 11.8 min, respectively. Peak height ratios were fit to a least squares linear regression algorithm with a 1/(concentration)2 weighting. The method produces acceptable linearity, precision and accuracy to a minimum concentration of 0.050 micrograms ml-1 in human plasma. It is also simple and convenient, with no observable matrix interferences.

  7. A C8-Modified Graphene@mSiO2 Composites Based Method for Quantification of Gallic Acid in Rat Plasma after Oral Administration of Changtai Granule and Its Application to Pharmacokinetics.

    PubMed

    Xu, Chen; Yu, Yingjia; Ling, Li; Wang, Yang; Zhang, Jundong; Li, Yan; Duan, Gengli

    2017-01-01

    A rapid, effective extraction technique has been established for measuring the gallic acid in rat plasma by using sandwich-structured graphene/mesoporous silica composites with C 8 -modified interior pore-walls as adsorbent. The unique characteristics of the graphene-silica composites excluded large molecules, like proteins, from the mesopore channels as a result of size exclusion effect, leading to a direct extraction of drug molecules from protein-rich biological samples such as plasma without any other pretreatment procedure. Followed by elution and centrifugation, the gallic acid-absorbed composites were rapidly isolated before LC-MS/MS. Serving as a reliable tool for analysis of Traditional Chinese Medicine: Changtai Granule, the newly developed method was fully validated and successfully applied in the pharmacokinetic study of gallic acid in rat plasma. Extraction recovery, matrix effect and stability were satisfactory in rat plasma. According to the results of pharmacokinetic studies, Changtai Granule exhibited greater adsorption, distribution and clearance properties of gallic acid in the treatment of ulcerative colitis. Hence, this study may offer a valuable alternative to simplify and speed up sample preparation, and be useful for clinical studies of related preparations.

  8. Determination of antazoline hydrochloride in rat plasma and excreta by reversed-phase ion-pair chromatography and its application to pharmacokinetics.

    PubMed

    Wang, Rui; Chu, Yanle; Li, Xiaotian; Wan, Baoluo; Yu, Tong; Wang, Linxi; Hao, Lianqi; Guo, Maowen

    2013-12-01

    A reversed-phase ion pair chromatography method with liquid-liquid extraction analytical method was developed and validated for the determination of antazoline hydrochloride in plasma and excreta of rat. The aim of our study was to characterize the preclinical pharmacokinetics and excretion profiles of antazoline hydrochloride in rats after intravenous injection at the dose of 10 mg/kg. Plasma and excreta samples were extracted with ethyl acetate, and phenacetin was used as the internal standard. The result showed that the method is suitable for the quantification of antazoline hydrochloride in plasma and excreta samples. Analysis of accuracy (90.89-112.33%), imprecision (<7.1%) and recovery (>82.5%) showed adequate values. After a single intravenous administration at 10 mg/kg to rats, plasma concentration profile showed a relative fast elimination proceeding with a terminal elimination half-life of 3.53 h. Approximately 61.8 and 14.2% of the administered dose were recovered in urine and bile after 72 and 24 h post-dosing respectively; 5.9% of the administered dose was recovered in feces after 72 h post-dosing. The above results show that the major elimination route is urinary excretion. Copyright © 2013 John Wiley & Sons, Ltd.

  9. Ultrasound assisted dispersive liquid-liquid microextraction coupled with high performance liquid chromatography designated for bioavailability studies of felodipine combinations in rat plasma.

    PubMed

    Ahmed, Sameh; Atia, Noha N; Bakr Ali, Marwa Fathy

    2017-03-01

    Felodipine (FLD), a calcium channel antagonist, is commonly prescribed for the treatment of hypertension either with Metoprolol (MET) or Ramipril (RAM) in two different drug combinations. FLD has high plasma protein binding ability affecting its extraction recoveries from plasma samples. Hence, a specific ultrasound assisted dispersive liquid-liquid microextraction (UA-DLLME) method coupled with HPLC using photodiode array detector was developed and validated for the simultaneous determination of FLD, MET and RAM in rat plasma after oral administration of these combinations. The factors affecting UA-DLLME were carefully optimized. In this study, UA-DLLME method could provide simple and efficient plasma extraction procedures with superior recovery results. Under optimum condition, all target drugs were separated within 13min. The validation procedures was carried out in agreement with US-FDA guidelines and shown to be suitable for anticipated purposes. Linear calibration ranges were obtained in the range 0.05-2.0μgmL -1 for FLD and MET and 0.1-2.0μgmL -1 for RAM with detection limits of 0.013-0.031μgmL -1 for all the studied drug combinations. The%RSD for inter-day and intra-day precisions was in range of 0.63-3.85% and the accuracy results were in the range of 92.13-100.5%. The validated UA-DLLME-HPLC method was successfully applied for the bioavailability studies of FLD, MET and RAM. The pharmacokinetic parameters were calculated for all the investigated drugs in rats after single-dose administrations of two different drug combinations. Although FLD was bioequivalent in the two formulations, a small increase in plasma levels of MET and RAM was found in the presence of FLD. Copyright © 2017 Elsevier B.V. All rights reserved.

  10. Approaching the investigation of plasma turbulence through a rigorous verification and validation procedure: A practical example

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Ricci, P., E-mail: paolo.ricci@epfl.ch; Riva, F.; Theiler, C.

    In the present work, a Verification and Validation procedure is presented and applied showing, through a practical example, how it can contribute to advancing our physics understanding of plasma turbulence. Bridging the gap between plasma physics and other scientific domains, in particular, the computational fluid dynamics community, a rigorous methodology for the verification of a plasma simulation code is presented, based on the method of manufactured solutions. This methodology assesses that the model equations are correctly solved, within the order of accuracy of the numerical scheme. The technique to carry out a solution verification is described to provide a rigorousmore » estimate of the uncertainty affecting the numerical results. A methodology for plasma turbulence code validation is also discussed, focusing on quantitative assessment of the agreement between experiments and simulations. The Verification and Validation methodology is then applied to the study of plasma turbulence in the basic plasma physics experiment TORPEX [Fasoli et al., Phys. Plasmas 13, 055902 (2006)], considering both two-dimensional and three-dimensional simulations carried out with the GBS code [Ricci et al., Plasma Phys. Controlled Fusion 54, 124047 (2012)]. The validation procedure allows progress in the understanding of the turbulent dynamics in TORPEX, by pinpointing the presence of a turbulent regime transition, due to the competition between the resistive and ideal interchange instabilities.« less

  11. In-house validation of a method for determination of silver nanoparticles in chicken meat based on asymmetric flow field-flow fractionation and inductively coupled plasma mass spectrometric detection.

    PubMed

    Loeschner, Katrin; Navratilova, Jana; Grombe, Ringo; Linsinger, Thomas P J; Købler, Carsten; Mølhave, Kristian; Larsen, Erik H

    2015-08-15

    Nanomaterials are increasingly used in food production and packaging, and validated methods for detection of nanoparticles (NPs) in foodstuffs need to be developed both for regulatory purposes and product development. Asymmetric flow field-flow fractionation with inductively coupled plasma mass spectrometric detection (AF(4)-ICP-MS) was applied for quantitative analysis of silver nanoparticles (AgNPs) in a chicken meat matrix following enzymatic sample preparation. For the first time an analytical validation of nanoparticle detection in a food matrix by AF(4)-ICP-MS has been carried out and the results showed repeatable and intermediately reproducible determination of AgNP mass fraction and size. The findings demonstrated the potential of AF(4)-ICP-MS for quantitative analysis of NPs in complex food matrices for use in food monitoring and control. The accurate determination of AgNP size distribution remained challenging due to the lack of certified size standards. Copyright © 2015 Elsevier Ltd. All rights reserved.

  12. Determination of Δ9-tetrahydrocannabinolic acid A (Δ9-THCA-A) in whole blood and plasma by LC-MS/MS and application in authentic samples from drivers suspected of driving under the influence of cannabis.

    PubMed

    Raikos, Nikolaos; Schmid, Helene; Nussbaumer, Susanne; Ambach, Lars; Lanz, Stephan; Längin, Andreas; König, Stefan; Roth, Nadine; Auwärter, Volker; Weinmann, Wolfgang

    2014-10-01

    Delta-9-tetrahydrocannabinolic acid A (THCA-A) is the biosynthetic precursor of delta-9-tetrahydrocannabinol (THC) in cannabis plants, and has no psychotropic effects. THCA-A can be detected in blood and urine, and several metabolites have been identified. THCA-A was also shown to be incorporated in hair by side stream smoke to a minor extent, but incorporation via blood stream or sweat seems unlikely. The detection of THCA-A in biological fluids may serve as a marker for differentiating between the intake of prescribed THC medication - containing only pure THC - and cannabis products containing THC besides THC-acid A and other cannabinoids. However, the knowledge about its usefulness in forensic cases is very limited. The aim of the present work was the development of a reliable method for THCA-A determination in human blood or plasma using LC-MS/MS and application to cases of driving under the influence of drugs. Fifty eight (58) authentic whole blood and the respective plasma samples were collected from drivers suspected of driving under the influence of cannabis from the region of Bern (Switzerland). Samples were first tested for THC, 11-OH-THC and THC-COOH, and then additionally for THCA-A. For this purpose, the existing LC-MS/MS method was modified and validated, and found to be selective and linear over a range of 1.0 to 200ng/mL (the correlation coefficients were above 0.9980 in all validation runs). Limit of detection (LOD) and limit of quantification (LOQ) were 0.3ng/mL and 1.0ng/mL respectively. Intra- and inter-assay accuracy were equal or better than 90% and intra- and inter-assay precision were equal or better than 11.1%. The mean extraction efficiencies were satisfactory being equal or higher than 85.4%. THCA-A was stable in whole blood samples after 3 freeze/thaw cycles and storage at 4°C for 7 days. Re-injection (autosampler) stability was also satisfactory. THC was present in all blood samples with levels ranging from 0.7 to 51ng/mL. THCA-A concentrations ranged from 1.0 to 496ng/mL in blood samples and from 1.4 to 824ng/mL in plasma samples. The plasma:blood partition coefficient had a mean value of 1.7 (±0.21, SD). No correlation was found between the degree of intoxication or impairment stated in the police protocols or reports of medical examinations and the detected THCA-A-concentration in blood. Copyright © 2014 Elsevier Ireland Ltd. All rights reserved.

  13. Microfluidic point-of-care blood panel based on a novel technique: Reversible electroosmotic flow

    PubMed Central

    Mohammadi, Mahdi; Madadi, Hojjat; Casals-Terré, Jasmina

    2015-01-01

    A wide range of diseases and conditions are monitored or diagnosed from blood plasma, but the ability to analyze a whole blood sample with the requirements for a point-of-care device, such as robustness, user-friendliness, and simple handling, remains unmet. Microfluidics technology offers the possibility not only to work fresh thumb-pricked whole blood but also to maximize the amount of the obtained plasma from the initial sample and therefore the possibility to implement multiple tests in a single cartridge. The microfluidic design presented in this paper is a combination of cross-flow filtration with a reversible electroosmotic flow that prevents clogging at the filter entrance and maximizes the amount of separated plasma. The main advantage of this design is its efficiency, since from a small amount of sample (a single droplet ∼10 μl) almost 10% of this (approx 1 μl) is extracted and collected with high purity (more than 99%) in a reasonable time (5–8 min). To validate the quality and quantity of the separated plasma and to show its potential as a clinical tool, the microfluidic chip has been combined with lateral flow immunochromatography technology to perform a qualitative detection of the thyroid-stimulating hormone and a blood panel for measuring cardiac Troponin and Creatine Kinase MB. The results from the microfluidic system are comparable to previous commercial lateral flow assays that required more sample for implementing fewer tests. PMID:26396660

  14. Novel liquid chromatography method based on linear weighted regression for the fast determination of isoprostane isomers in plasma samples using sensitive tandem mass spectrometry detection.

    PubMed

    Aszyk, Justyna; Kot, Jacek; Tkachenko, Yurii; Woźniak, Michał; Bogucka-Kocka, Anna; Kot-Wasik, Agata

    2017-04-15

    A simple, fast, sensitive and accurate methodology based on a LLE followed by liquid chromatography-tandem mass spectrometry for simultaneous determination of four regioisomers (8-iso prostaglandin F 2α , 8-iso-15(R)-prostaglandin F 2α , 11β-prostaglandin F 2α , 15(R)-prostaglandin F 2α ) in routine analysis of human plasma samples was developed. Isoprostanes are stable products of arachidonic acid peroxidation and are regarded as the most reliable markers of oxidative stress in vivo. Validation of method was performed by evaluation of the key analytical parameters such as: matrix effect, analytical curve, trueness, precision, limits of detection and limits of quantification. As a homoscedasticity was not met for analytical data, weighted linear regression was applied in order to improve the accuracy at the lower end points of calibration curve. The detection limits (LODs) ranged from 1.0 to 2.1pg/mL. For plasma samples spiked with the isoprostanes at the level of 50pg/mL, intra-and interday repeatability ranged from 2.1 to 3.5% and 0.1 to 5.1%, respectively. The applicability of the proposed approach has been verified by monitoring of isoprostane isomers level in plasma samples collected from young patients (n=8) subjected to hyperbaric hyperoxia (100% oxygen at 280kPa(a) for 30min) in a multiplace hyperbaric chamber. Copyright © 2017 Elsevier B.V. All rights reserved.

  15. Development and validation of a HPLC-MS/MS method for the determination of phytolaccagenin in rat plasma and application to a pharmacokinetic study.

    PubMed

    Wei, Fenghuan; Singh, Ravi Shankar Prasad; Fueth, Matthias; Swarts, Steven; Okunieff, Paul; Derendorf, Hartmut

    2015-03-25

    Radix Phytolaccae (the dried root of Phytolacca acinosa Roxb. or Phytolacca americana L.) is widely used in East Asian countries for the treatment of inflammation-related diseases. The active component of Radix Phtolaccae is Phytolcaccagenin a triterpenoid saponin. Phytolcaccagenin has anti-inflammatory activities that exceed those of Esculentoside A and its derivatives regarding suppression of LPS-induced inflammation, and has a lower toxicity profile with less hemolysis. To date, no information is available about analytical method and pharmacokinetic studies of phytolaccagenin. To explore PK profile of this compound, a HPLC-MS/MS assay of phytolaccagenin in rat plasma was developed and validated. The method was fully validated according to FDA Guidance for industry. The detection was performed by a triple-quadrupole tandem mass spectrometer with multiple reactions monitoring (MRM) in positive ion mode via electrospray ionization. The monitored transitions were m/z 533.2>515.3 for Phytolcaccagenin, and 491.2>473.2 for I.S. The analysis was performed on a Symmetry C18 column (4.6 mm × 50 mm, 3.5 μm) using gradient elution with the mobile phase consisting of acetonitrile and 0.1% formic acid water at a flow rate of 1 ml/min with a 1:1 splitter ratio. The method was validated with a LLOQ of 20 ng/ml and an ULOQ of 1000 ng/ml. The response versus concentration data were fitted with 1/x weighting and the correlation coefficient (r) were greater than 0.999. The average matrix effect and the average extraction recovery were acceptable. This validation in rat plasma demonstrated that phytolaccagenin was stable for 30 days when stored below -20°C, for 6h at room temperature (RT, 22°C), for 12 h at RT for prepared control samples in auto-sampler vials, and during three successive freeze/thaw cycles results at -20°C. The validated method has been successfully applied to an intravenous bolus pharmacokinetic study of phytolaccagenin in male Sprague-Dawley rats (10 mg/kg, i.v.). Blood samples taken from 0 to 24h after injection were collected, and data analyzed with WinNonlin. The half-life and clearance were 1.4±0.9 h and 2.1±1.1 L/h/kg, respectively. Copyright © 2014 Elsevier B.V. All rights reserved.

  16. Identifying potential markers in Breast Cancer subtypes using plasma label-free proteomics.

    PubMed

    Corrêa, Stephany; Panis, Carolina; Binato, Renata; Herrera, Ana Cristina; Pizzatti, Luciana; Abdelhay, Eliana

    2017-01-16

    Breast Cancer (BC) is the most common neoplasia among women and has a high mortality rate worldwide. Over the past several decades, increasing molecular knowledge of BC has resulted in its stratification into 4 major molecular subtypes according to hormonal receptor expression. Unfortunately, although the data accumulated thus far has improved BC prognosis and treatment, there have been few achievements in its diagnosis. In this study, we applied a Label-free Nano-LC/MSMS approach to reveal systemic molecular features and possible plasma markers for BC patients. Compared to healthy control plasma donors, we identified 191, 166, 182, and 186 differentially expressed proteins in the Luminal, Lumina-HER2, HER2, and TN subtypes. In silico analysis demonstrated an overall downregulation of cellular basal machinery and, more importantly, brought new focus to the known pathways and signaling molecules in BC that are related to immune system alterations. Moreover, using western blot analysis, we verified high levels of BCAS3, IRX1, IRX4 and IRX5 in BC plasma samples, thus highlighting the potential use of plasma proteomics in investigations into cancer biomarkers. The results of this study provide new insight into Breast Cancer (BC). We determined the plasma proteomic profile of BC subtypes. Furthermore, we report that the signaling pathways correlating with late processes in BC already exhibit plasma alterations in less aggressive subtypes. Additionally, we validated the high levels of particular proteins in patient samples, which suggests the use of these proteins as potential disease markers.

  17. Further evidence for plasma progranulin as a biomarker in bipolar disorder.

    PubMed

    Kittel-Schneider, Sarah; Weigl, Johannes; Volkert, Julia; Geßner, Alexandra; Schmidt, Brigitte; Hempel, Susanne; Kiel, Tilman; Olmes, David G; Bartl, Jasmin; Weber, Heike; Kopf, Juliane; Reif, Andreas

    2014-03-01

    A recent study suggested that progranulin (encoded by the fronto-temporal dementia risk gene GRN) plasma levels are decreased in bipolar disorder (BD). Replication of this finding is however lacking. Progranulin plasma levels of bipolar patients (n=104) and healthy controls (n=80) were measured by enzyme-linked immunosorbent assay (ELISA). Participants were also genotyped for three single nucleotide polymorphisms (SNPs) in the GRN gene (rs2879096, rs4792938 and rs5848), and the effect of genetic variation on progranulin levels was examined. Plasma progranulin levels were decreased in BD (ANCOVA, p=0.001). Furthermore, age was significantly and positively correlated with plasma progranulin (Pearson׳s correlation, r=0.269, p<0.001). Also, lithium treatment but no other medication had a significant effect on progranulin plasma levels (ANCOVA, p=0.007). Specifically in BD, the GRN SNP rs5848 was associated with progranulin plasma levels (Kruskal-Wallis test, p<0.005). Subgroup analysis regarding bipolar I vs. bipolar II subtype and polarity of the episode at sampling (manic vs. depressed vs. mixed vs. rapid cycling vs. euthymic) could only be performed with limited validity due to the relatively small sample size. The suitability of peripheral progranulin as a biomarker for BD is limited due to the overlap between patients and controls. The findings strengthen the evidence for progranulin being involved in pathomechanisms of bipolar disorder, and suggest a genetic determinant of progranulin concentrations that is relevant specifically in bipolar patients. Copyright © 2014 Elsevier B.V. All rights reserved.

  18. Comparison of femtosecond and nanosecond laser ablation inductively coupled plasma mass spectrometry for uranium isotopic measurements

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Havrilla, George Joseph; McIntosh, Kathryn Gallagher; Judge, Elizabeth

    2016-10-20

    Feasibility tests were conducted using femtosecond and nanosecond laser ablation inductively coupled plasma mass spectrometry for rapid uranium isotopic measurements. The samples used in this study consisted of a range of pg quantities of known 235/238 U solutions as dried spot residues of 300 pL drops on silicon substrates. The samples spanned the following enrichments of 235U: 0.5, 1.5, 2, 3, and 15.1%. In this direct comparison using these particular samples both pulse durations demonstrated near equivalent data can be produced on either system with respect to accuracy and precision. There is no question that either LA-ICP-MS method offers themore » potential for rapid, accurate and precise isotopic measurements of U10Mo materials whether DU, LEU or HEU. The LA-ICP-MS equipment used for this work is commercially available. The program is in the process of validating this work for large samples using center samples strips from Y-12 MP-1 LEU-Mo Casting #1.« less

  19. Advantages of automation in plasma sample preparation prior to HPLC/MS/MS quantification: application to the determination of cilazapril and cilazaprilat in a bioequivalence study.

    PubMed

    Kolocouri, Filomila; Dotsikas, Yannis; Apostolou, Constantinos; Kousoulos, Constantinos; Soumelas, Georgios-Stefanos; Loukas, Yannis L

    2011-01-01

    An HPLC/MS/MS method characterized by complete automation and high throughput was developed for the determination of cilazapril and its active metabolite cilazaprilat in human plasma. All sample preparation and analysis steps were performed by using 2.2 mL 96 deep-well plates, while robotic liquid handling workstations were utilized for all liquid transfer steps, including liquid-liquid extraction. The whole procedure was very fast compared to a manual procedure with vials and no automation. The method also had a very short chromatographic run time of 1.5 min. Sample analysis was performed by RP-HPLC/MS/MS with positive electrospray ionization using multiple reaction monitoring. The calibration curve was linear in the range of 0.500-300 and 0.250-150 ng/mL for cilazapril and cilazaprilat, respectively. The proposed method was fully validated and proved to be selective, accurate, precise, reproducible, and suitable for the determination of cilazapril and cilazaprilat in human plasma. Therefore, it was applied to a bioequivalence study after per os administration of 2.5 mg tablet formulations of cilazapril.

  20. Determination of Cloretazine (VNP40101M) and its active metabolite (VNP4090CE) in human plasma by liquid chromatography electrospray tandem mass spectrometry (LC-ESI-MS/MS).

    PubMed

    Bai, Feng; Minkin, Patton; Fraga, Charles H; O'Shaughnessy, Melinda A; Gururangan, Sri; Stewart, Clinton F

    2007-06-15

    A sensitive method for the determination of Cloretazine (VNP40101M) and its metabolite (VNP4090CE) with an internal standard (ISTD) in human plasma was developed using high-performance liquid chromatographic separation with tandem mass spectrometric detection. Acidified plasma samples (500 microL) were prepared using solid phase extraction (SPE) columns, and 25 microL of the reconstituted sample was injected onto an Ascentis C18 HPLC column (3 microm, 5 cmx2.1 mm) with an isocratic mobile phase. Analytes were detected with an API-3000 LC-MS/MS System at unit (Q1) and low (Q3) resolution in negative multiple reaction monitoring mode: m/z 249.0 (precursor ion) to m/z 114.9 (product ion) for both Cloretazine (at 3.64 min) and VNP4090CE (at 2.91 min), and m/z 253.0 (precursor ion) to m/z 116.9 (product ion) for the ISTD. The mean recovery for Cloretazine (VNP40101M) and its metabolite (VNP4090CE) was greater than 87% with a lower limit of quantification of 1.0 ng/mL for Cloretazine (S/N=9.7, CV

  1. Determination of aniracetam's main metabolite, N-anisoyl-GABA, in human plasma by LC-MS/MS and its application to a pharmacokinetic study.

    PubMed

    Cai, Shuang; Wang, Lei

    2012-05-15

    A simple and rapid high-performance liquid chromatography-electrospray ionization tandem mass spectrometry (LC-ESI-MS/MS) method has been developed and validated for the determination of 4-p-anisamidobutyric acid (ABA; or N-anysoyl-γ-aminobutiryc acid, N-anisoyl-GABA), a major active metabolite of aniracetam, in human plasma. After protein precipitation of plasma sample with methanol, ABA and the internal standard lisinopril were separated on a Venusil ASB C₁₈ column at 25 °C. The mobile phase consisted of methanol-ammonium acetate (10 mmol/L) (30:70, v/v). The detection was performed on a triple quadrupole tandem mass spectrometer with an ESI source in negative ion mode. Multiple reaction monitoring (MRM) using the precursor→product ion combinations of m/z 235.8→m/z 106.6, and m/z 403.8→m/z 113.6 was used to quantify ABA and lisinopril, respectively. This is the first LC-MS/MS method for ABA with advantages of short analysis time (4.5 min per sample run) and high selectivity attributable to the MRM detection and optimized HPLC conditions. The response was linear in a concentration range of 0.0485-19.4 μg/mL in plasma. The extraction recovery of ABA was between 89.1% and 100.7%. The precision (RSD) and accuracy (RE) of the method were evaluated to be within 7.3% and from 2.5% to 6.9%. The validated method has been applied to the pharmacokinetic study after a single oral administration of aniracetam dispersible tablets to human beings. Copyright © 2012 Elsevier B.V. All rights reserved.

  2. Ultra-high performance liquid chromatography tandem mass spectrometric method for the determination of tamoxifen, N-desmethyltamoxifen, 4-hydroxytamoxifen and endoxifen in dried blood spots--development, validation and clinical application during breast cancer adjuvant therapy.

    PubMed

    Antunes, Marina Venzon; Raymundo, Suziane; de Oliveira, Vanessa; Staudt, Dilana Elisabeth; Gössling, Gustavo; Peteffi, Giovana Piva; Biazús, Jorge Villanova; Cavalheiro, José Antônio; Tre-Hardy, Marie; Capron, Arnaud; Haufroid, Vincent; Wallemacq, Pierre; Schwartsmann, Gilberto; Linden, Rafael

    2015-01-01

    A LC-MSMS method for the simultaneous determination of tamoxifen, N-desmethyltamoxifen, 4-hydroxytamoxifen and endoxifen in dried blood spots samples was developed and validated. The method employs an ultrasound-assisted liquid extraction and a reversed phase separation in an Acquity(®) C18 column (150×2.1 mm, 1.7 µm). Mobile phase was a mixture of formic acid 0.1% (v/v) pH 2.7 and acetonitrile (gradient from 60:40 to 50:50, v/v). Total analytical run time was 8 min. Precision assays showed CV % lower than 10.75% and accuracy in the range 94.5 to 110.3%. Mean analytes recoveries from DBS ranged from 40% to 92%. The method was successfully applied to 91 paired clinical DBS and plasma samples. Dried blood spots concentrations were highly correlated to plasma, with rs>0.83 (P<0.01). Median estimated plasma concentrations after hematocrit and partition factor adjustment were: TAM 123.3 ng mL(-1); NDT 267.9 ng mL(-1), EDF 10.0 ng mL(-1) and HTF 1.3 ng mL(-1,) representing in average 98 to 104% of the actually measured concentrations. The DBS method was able to identify 96% of patients with plasma EDF concentrations below the clinical threshold related to better prognosis (5.9 ng mL(-1)). The procedure has adequate analytical performance and can be an efficient tool to optimize adjuvant breast cancer treatment, especially in resource limited settings. Copyright © 2014 Elsevier B.V. All rights reserved.

  3. A parallel chiral-achiral liquid chromatographic method for the determination of the stereoisomers of ketamine and ketamine metabolites in the plasma and urine of patients with complex regional pain syndrome

    PubMed Central

    Moaddel, Ruin; Venkata, Swarajya Lakshmi Vattem; Tanga, Mary J.; Bupp, James E.; Green, Carol E.; Iyer, Lalitha; Furimsky, Anna; Goldberg, Michael E.; Torjman, Marc C.; Wainer, Irving W.

    2010-01-01

    A parallel chiral/achiral LC-MS/MS assay has been developed and validated to measure the plasma and urine concentrations of the enantiomers of ketamine, (R)- and (S)-Ket, in Complex Regional Pain Syndrome (CRPS) patients receiving a 5-day continuous infusion of a sub-anesthetic dose of (R,S)-Ket. The method was also validated for the determination of the enantiomers of the Ket metabolites norketamine, (R)-and (S)-norKet and dehydronorketamine, (R)- and (S)-DHNK, as well as the diastereomeric metabolites hydroxynorketamine, (2S,6S)-/(2R,6R)-HNK and two hydroxyketamines, (2S,6S)-HKet and (2S,6R)-Hket. In this method, (R,S)-Ket, (R,S)-norKet and (R,S)-DHNK and the diastereomeric hydroxyl-metabolites were separated and quantified using a C18 stationary phase and the relative enantiomeric concentrations of (R,S)-Ket, (R,S)-norKet and (R,S)-DHNK were determined using an AGP-CSP. The analysis of the results of microsomal incubations of (R)- and (S)-Ket and a plasma and urine sample from a CRPS patient indicated the presence of 10 additional compounds and glucuronides. The data from the analysis of the patient sample also demonstrated that a series of HNK metabolites were the primary metabolites in plasma and (R)- and (S)-DHNK were the major metabolites found in urine. The results suggest that norKet is the initial, but not the primary, metabolite and that downstream norKet metabolites play a role in (R,S)-Ket-related pain relief in CRPS patients. PMID:20875593

  4. A parallel chiral-achiral liquid chromatographic method for the determination of the stereoisomers of ketamine and ketamine metabolites in the plasma and urine of patients with complex regional pain syndrome.

    PubMed

    Moaddel, Ruin; Venkata, Swarajya Lakshmi Vattem; Tanga, Mary J; Bupp, James E; Green, Carol E; Iyer, Lalitha; Furimsky, Anna; Goldberg, Michael E; Torjman, Marc C; Wainer, Irving W

    2010-10-15

    A parallel chiral/achiral LC-MS/MS assay has been developed and validated to measure the plasma and urine concentrations of the enantiomers of ketamine, (R)- and (S)-Ket, in complex regional pain syndrome (CRPS) patients receiving a 5-day continuous infusion of a sub-anesthetic dose of (R,S)-Ket. The method was also validated for the determination of the enantiomers of the Ket metabolites norketamine, (R)- and (S)-norKet and dehydronorketamine, (R)- and (S)-DHNK, as well as the diastereomeric metabolites hydroxynorketamine, (2S,6S)-/(2R,6R)-HNK and two hydroxyketamines, (2S,6S)-HKet and (2S,6R)-Hket. In this method, (R,S)-Ket, (R,S)-norKet and (R,S)-DHNK and the diastereomeric hydroxyl-metabolites were separated and quantified using a C(18) stationary phase and the relative enantiomeric concentrations of (R,S)-Ket, (R,S)-norKet and (R,S)-DHNK were determined using an AGP-CSP. The analysis of the results of microsomal incubations of (R)- and (S)-Ket and a plasma and urine sample from a CRPS patient indicated the presence of 10 additional compounds and glucuronides. The data from the analysis of the patient sample also demonstrated that a series of HNK metabolites were the primary metabolites in plasma and (R)- and (S)-DHNK were the major metabolites found in urine. The results suggest that norKet is the initial, but not the primary metabolite and that downstream norKet metabolites play a role in (R,S)-Ket-related pain relief in CRPS patients. Published by Elsevier B.V.

  5. High-throughput SISCAPA quantitation of peptides from human plasma digests by ultrafast, liquid chromatography-free mass spectrometry.

    PubMed

    Razavi, Morteza; Frick, Lauren E; LaMarr, William A; Pope, Matthew E; Miller, Christine A; Anderson, N Leigh; Pearson, Terry W

    2012-12-07

    We investigated the utility of an SPE-MS/MS platform in combination with a modified SISCAPA workflow for chromatography-free MRM analysis of proteotypic peptides in digested human plasma. This combination of SISCAPA and SPE-MS/MS technology allows sensitive, MRM-based quantification of peptides from plasma digests with a sample cycle time of ∼7 s, a 300-fold improvement over typical MRM analyses with analysis times of 30-40 min that use liquid chromatography upstream of MS. The optimized system includes capture and enrichment to near purity of target proteotypic peptides using rigorously selected, high affinity, antipeptide monoclonal antibodies and reduction of background peptides using a novel treatment of magnetic bead immunoadsorbents. Using this method, we have successfully quantitated LPS-binding protein and mesothelin (concentrations of ∼5000 ng/mL and ∼10 ng/mL, respectively) in human plasma. The method eliminates the need for upstream liquid-chromatography and can be multiplexed, thus facilitating quantitative analysis of proteins, including biomarkers, in large sample sets. The method is ideal for high-throughput biomarker validation after affinity enrichment and has the potential for applications in clinical laboratories.

  6. An easy-to-use liquid chromatography assay for the analysis of lamotrigine in rat plasma and brain samples using microextraction by packed sorbent: Application to a pharmacokinetic study.

    PubMed

    Ventura, Sandra; Rodrigues, Márcio; Pousinho, Sarah; Falcão, Amílcar; Alves, Gilberto

    2016-11-01

    A simple and rapid high-performance liquid chromatography method with diode-array detection (HPLC-DAD) using microextraction by packed sorbent (MEPS) during the sample preparation step was developed and validated to quantify lamotrigine (LTG) in rat plasma and brain samples. MEPS variables such as pH, number of draw-eject cycles, and washing and desorption conditions were optimized. The chromatographic resolution of LTG and chloramphenicol, used as internal standard (IS), was accomplished in less than 5min on a C18 column, at 35°C, using an isocratic elution with acetonitrile (13%), methanol (13%) and water-triethylamine (99.7:0.3, v/v; pH 6.0) pumped at a flow rate of 1mL/min. Detection was performed at 215nm. Calibration curves were linear over the range of 0.1-20μg/mL (r 2 ≥0.9947) for LTG in both rat plasma and brain homogenate samples. The intra and interday imprecision did not exceed 8.6% and the intra and interday inaccuracy ranged from -8.1 to 13.5%. LTG was extracted from rat plasma and brain homogenate samples with an average absolute recovery ranging from 68.0 to 86.7%, and its stability was demonstrated in the assayed conditions. No interferences were observed at the retention times of the analyte (LTG) and IS. To the best of our knowledge, this is the first bioanalytical assay that uses MEPS procedure for the determination of LTG not only in rat plasma but also in tissue (brain) samples. This novel method was successfully applied to a preliminary pharmacokinetic study in rats and it seems to be a cost-effective tool to support non-clinical pharmacokinetic-based studies involving LTG treatment. Copyright © 2016 Elsevier B.V. All rights reserved.

  7. Simultaneous determination of blonanserin and its four metabolites in human plasma using ultra-performance liquid chromatography-tandem mass spectrometry.

    PubMed

    Zhou, Ying; Liu, Ming; Jiang, Ji; Wang, Hongyun; Hu, Pei

    2013-11-15

    A sensitive and rapid method based on ultra-performance liquid chromatography coupled with tandem mass spectrometry (UPLC-MS/MS) was developed and validated for the simultaneous determination of blonanserin, its major active metabolite (N-deethyl form) and other three metabolites (N-oxide form, Ethylenediamine form and Carboxylate form) in human plasma. Plasma samples were pre-purified by solid-phase extraction (SPE) and analyzed using a gradient chromatographic separation over an Acquity UPLC CSH C18 column. The mobile phase consisted of acetonitrile-water containing 5mM ammonium formate and 0.1% formic acid at a flow rate of 0.5mL/min. Positive electrospray ionization was employed as the ionization source in the multiple reaction monitoring (MRM) mode. The analysis time was about 3.5min. The method was fully validated over the concentration range of 0.01-1ng/mL for all analytes. The lower limit of quantification (LLOQ) was 0.01ng/mL. Inter- and intra-batch precision was less than 15% and the accuracy was within 85-115%. The mean extraction recoveries of all analytes at two concentration levels were consistent. Selectivity, matrix effect and stability were also validated. The method was applied to the pharmacokinetic study of blonanserin in Chinese healthy subjects. Copyright © 2013 Elsevier B.V. All rights reserved.

  8. Development of Validated Bioanalytical HPLC-UV Method for Simultaneous Estimation of Amlodipine and Atorvastatin in Rat Plasma

    PubMed Central

    Talele, G. S.; Porwal, P. K.

    2015-01-01

    A simple, economical and robust analytical high-performance liquid chromatography-ultraviolet method was developed and validated for simultaneous chromatographic elution of two cardiovascular drugs viz. amlodipine and atorvastatin in biological fluid for the first time. Only two liquid chromatography–mass spectrometry/mass spectrometry methods are available in literature for quantitation of selected pair of analytes. The bioanalytical method was developed in rat plasma by using Thermo beta-basic C18 (100×4.6 mm, 5 μm) and mobile phase was composed of dibasic phosphate buffer (pH 3.0):acetonitrile in the ratio of 55:45 at a flow rate of 1 ml/min with ultraviolet detection monitored at 240 nm. The selected chromatographic conditions were found to effectively separate amlodipine (5.1 min) and atorvastatin (12.1 min). The parametric statistics,i.e. correlation coefficient of 0.999, was assessed for both the drugs having linearity over the tested concentration range (0.05 to 10.0 μg/ml) in rat plasma using an unweighted calibration curve. The mean recovery (%) was more than 92.8% for both the drugs using protein precipitation method. The accuracy of samples for six replicate measurements at lower limit of quantitation level was within limit. The method was validated and was successfully applied to the nonclinical pharmacokinetic study of combination tablets containing amlodipine and atorvastatin in six Sprague Dawley rats. PMID:26997703

  9. Rapid and sensitive determination of tellurium in soil and plant samples by sector-field inductively coupled plasma mass spectrometry.

    PubMed

    Yang, Guosheng; Zheng, Jian; Tagami, Keiko; Uchida, Shigeo

    2013-11-15

    In this work, we report a rapid and highly sensitive analytical method for the determination of tellurium in soil and plant samples using sector field inductively coupled plasma mass spectrometry (SF-ICP-MS). Soil and plant samples were digested using Aqua regia. After appropriate dilution, Te in soil and plant samples was directly analyzed without any separation and preconcentration. This simple sample preparation approach avoided to a maximum extent any contamination and loss of Te prior to the analysis. The developed analytical method was validated by the analysis of soil/sediment and plant reference materials. Satisfactory detection limits of 0.17 ng g(-1) for soil and 0.02 ng g(-1) for plant samples were achieved, which meant that the developed method was applicable to studying the soil-to-plant transfer factor of Te. Our work represents for the first time that data on the soil-to-plant transfer factor of Te were obtained for Japanese samples which can be used for the estimation of internal radiation dose of radioactive tellurium due to the Fukushima Daiichi Nuclear Power Plant accident. Copyright © 2013 Elsevier B.V. All rights reserved.

  10. [Comparison between the LightCycler CMV Quant Kit (Roche Diagnostics) with a standardized in-house Taqman assay for cytomegalovirus blood viral load quantification].

    PubMed

    Alain, S; Lachaise, V; Hantz, S; Denis, F

    2010-04-01

    The broad use of cytomegalovirus (CMV) viral load quantification in blood to follow immunosuppressed patients need standardized assays. Choice of whole blood allows follow-up for several viruses and simplifies pretreatment and storage of samples. We therefore evaluated the LightCycler CMV Quant Kit (Roche Diagnostics) assay on whole blood after a manual extraction (High Pure viral nucleic acid kit, Roche Diagnostics), using as a reference an in-house Taqman assay (LC1UL83) which has been validated in various clinical situations. A panel obtained by serial dilutions of a virion stock in CMV whole blood, a commercial plasma quality control (VQC, Argène, France) crude or diluted in whole blood, infected cells extracts and 46 clinical samples from transplanted patients were tested simultaneously by both techniques. For plasma quality controls, both PCR assays are correlated VQC (R(2)=0.93). On whole blood or infected cells dilutions, correlation shows an overestimation by the LC1UL83 assay (mean 1.2 log copies/ml) over 3 log though R(2)=0.94. Results with CMV Quant Kit are closer to expected values. Results on clinical samples are close to quality controls with a lower variation of quantification (0.76 log copies/ml). CMV Quant Kit performs well when compared with a clinically validated PCR. Quality control results showed discrepancies between plasma and whole blood, demonstrating the need for whole blood standardized panels to compare the methods. This underlines the need to follow a patient with the same technique during his follow-up. Copyright 2009 Elsevier Masson SAS. All rights reserved.

  11. Quantification of Rifapentine, a Potent Antituberculosis Drug, from Dried Blood Spot Samples Using Liquid Chromatographic-Tandem Mass Spectrometric Analysis

    PubMed Central

    Parsons, Teresa L.; Marzinke, Mark A.; Hoang, Thuy; Bliven-Sizemore, Erin; Weiner, Marc; Mac Kenzie, William R.; Dorman, Susan E.

    2014-01-01

    The quantification of antituberculosis drug concentrations in multinational trials currently requires the collection of modest blood volumes, centrifugation, aliquoting of plasma, freezing, and keeping samples frozen during shipping. We prospectively enrolled healthy individuals into the Tuberculosis Trials Consortium Study 29B, a phase I dose escalation study of rifapentine, a rifamycin under evaluation in tuberculosis treatment trials. We developed a liquid chromatography-tandem mass spectrometry (LC-MS/MS) method for quantifying rifapentine in whole blood on dried blood spots (DBS) to facilitate pharmacokinetic/pharmacodynamic analyses in clinical trials. Paired plasma and whole-blood samples were collected by venipuncture, and whole blood was spotted on Whatman protein saver 903 cards. The methods were optimized for plasma and then validated for DBS. The analytical measuring range for quantification of rifapentine and its metabolite was 50 to 80,000 ng/ml in whole-blood DBS. The analyte was stable on the cards for 11 weeks with a desiccant at room temperature and protected from light. The method concordance for paired plasma and whole-blood DBS samples was determined after correcting for participant hematocrit or population-based estimates of bias from Bland-Altman plots. The application of either correction factor resulted in acceptable correlation between plasma and whole-blood DBS (Passing-Bablok regression corrected for hematocrit; y = 0.98x + 356). Concentrations of rifapentine may be determined from whole-blood DBS collected via venipuncture after normalization in order to account for the dilutional effects of red blood cells. Additional studies are focused on the application of this methodology to capillary blood collected by finger stick. The simplicity of processing, storage, shipping, and low blood volume makes whole-blood DBS attractive for rifapentine pharmacokinetic evaluations, especially in international and pediatric trials. PMID:25182637

  12. Quantitative determination of mogroside V in rat plasma by LC-MS/MS and its application to a pharmacokinetic study.

    PubMed

    Yan, Huiyu; Tao, Lina; Qu, Xiaoyu; Zhou, Liting; Zhang, Sixi

    2018-05-01

    Mogroside V is the most abundant (approximately 0.50%) cucurbitane-type triterpene glycoside in Siraitia grosvenorii and exhibits significant antitussive, expectorant, anti-carcinogenic, and anti-inflammatory effects. A sensitive, robust and selective liquid chromatography tandem with mass spectrometry (LC-MS/MS) was developed and validated for the determination and pharmacokinetic investigation of mogroside V in rat plasma. Samples were prepared through an one-step deproteinization procedure with 250 µL of methanol to a 75-µL plasma sample. Plasma samples were effectively separated on a Shiseido Capcell Pak UG120 C18 column (2.0 × 50mm, 3.0µm) using a mobile phase consisting of methanol: water (60:40, v/v) with an isocratic elution program. The running time for each sample was 7.0 min and the elution times of mogroside V and IS were 2.0 and 4.8 min, respectively. The detection relied on a triple-quadrupole tandem with mass spectrometer equipped with negative-ion electrospray ionization interface by selected-reaction monitoring (SRM) of the transitions at m/z 1285.6 → 1123.7 for mogroside V and m/z 1089.6 → 649.6 for IS. The calibration curve was linear over the range of 96.0-96000ng/mL with a limit of quantitation (LOQ) of 96.0ng/mL. Intra-day and inter-day precisions were both <10.1%. Mean recovery and matrix effect of mogroside V in plasma were in the range of 91.3-95.7% and 98.2-105.0%, respectively. This method was successfully applied in the pharmacokinetic study of mogroside V after intravenous or intraperitoneal administration of 1.12mg/kg mogroside V in rats.

  13. A Simple Method to Measure Renal Function in Swine by the Plasma Clearance of Iohexol

    PubMed Central

    Luis-Lima, Sergio; García-Contreras, Consolación; Carrara, Fabiola; Negrín-Mena, Natalia; Jiménez-Sosa, Alejandro; Jiménez-Hernández, Hugo; Porrini, Esteban

    2018-01-01

    There is no simple method to measure glomerular filtration rate (GFR) in swine, an established model for studying renal disease. We developed a protocol to measure GFR in conscious swine by using the plasma clearance of iohexol. We used two groups, test and validation, with eight animals each. Ten milliliters of iohexol (6.47 g) was injected into the marginal auricular vein and blood samples (3 mL) were collected from the orbital sinus at different points after injection. GFR was determined using two models: two-compartment (CL2: all samples) and one-compartment (CL1: the last six samples). In the test group, CL1 overestimated CL2 by ~30%: CL2 = 245 ± 93 and CL1 = 308 ± 123 mL/min. This error was corrected by a first-order polynomial quadratic equation to CL1, which was considered the simplified method: SM = −47.909 + (1.176xCL1) − (0.00063968xCL12). The SM showed narrow limits of agreement with CL2, a concordance correlation of 0.97, and a total deviation index of 14.73%. Similar results were obtained for the validation group. This protocol is reliable, reproducible, can be performed in conscious animals, uses a single dose of the marker, and requires a reduced number of samples, and avoids urine collection. Finally, it presents a significant improvement in animal welfare conditions and handling necessities in experimental trials. PMID:29329247

  14. Improved detection of CXCR4-using HIV by V3 genotyping: application of population-based and "deep" sequencing to plasma RNA and proviral DNA.

    PubMed

    Swenson, Luke C; Moores, Andrew; Low, Andrew J; Thielen, Alexander; Dong, Winnie; Woods, Conan; Jensen, Mark A; Wynhoven, Brian; Chan, Dennison; Glascock, Christopher; Harrigan, P Richard

    2010-08-01

    Tropism testing should rule out CXCR4-using HIV before treatment with CCR5 antagonists. Currently, the recombinant phenotypic Trofile assay (Monogram) is most widely utilized; however, genotypic tests may represent alternative methods. Independent triplicate amplifications of the HIV gp120 V3 region were made from either plasma HIV RNA or proviral DNA. These underwent standard, population-based sequencing with an ABI3730 (RNA n = 63; DNA n = 40), or "deep" sequencing with a Roche/454 Genome Sequencer-FLX (RNA n = 12; DNA n = 12). Position-specific scoring matrices (PSSMX4/R5) (-6.96 cutoff) and geno2pheno[coreceptor] (5% false-positive rate) inferred tropism from V3 sequence. These methods were then independently validated with a separate, blinded dataset (n = 278) of screening samples from the maraviroc MOTIVATE trials. Standard sequencing of HIV RNA with PSSM yielded 69% sensitivity and 91% specificity, relative to Trofile. The validation dataset gave 75% sensitivity and 83% specificity. Proviral DNA plus PSSM gave 77% sensitivity and 71% specificity. "Deep" sequencing of HIV RNA detected >2% inferred-CXCR4-using virus in 8/8 samples called non-R5 by Trofile, and <2% in 4/4 samples called R5. Triplicate analyses of V3 standard sequence data detect greater proportions of CXCR4-using samples than previously achieved. Sequencing proviral DNA and "deep" V3 sequencing may also be useful tools for assessing tropism.

  15. Technical note: Validation of a handheld meter for measuring β-hydroxybutyrate concentrations in plasma and serum from dairy cows.

    PubMed

    Pineda, A; Cardoso, F C

    2015-12-01

    The use of handheld meters for cow-side tests for β-hydroxybutyrate (BHB) concentrations in whole blood has become common. The aim of this study was to compare serum BHB (sBHB) and plasma BHB (pBHB) concentrations analyzed using either a "gold standard" enzymatic laboratory method (LM; Randox Laboratories Ltd., Antrim, UK; cat. no. RB1007) or a handheld meter (PX; Precision Xtra, Abbott Diabetes Care Inc., Alameda, CA). Results from 374 (187 serum and 187 plasma) samples taken from Holstein cows from 11 d before (52 samples) to 5 d after parturition (137 samples) were used for the analysis. Statistical analysis was performed using the MIXED, REG, and LOGISTIC procedures of SAS (v9.4; SAS Institute Inc., Cary, NC). A linear mixed model with repeated measures was fitted for LM and PX. Regression and correlation analyses were completed to estimate the relationship and agreement between the 2 methods. Lin's concordance correlation coefficient (CCC) and Bland-Altman plots were used to evaluate agreement between LM and PX. Cross-validation by randomly splitting the data in model-building and validation sets was performed to estimate and validate the equation that predicted the LM results using PX. Receiver operating characteristic (ROC) curves were used to estimate the sensitivity (Se) and specificity (Sp) of PX at different threshold levels. The CCC was 0.74 for pBHB and 0.68 for sBHB. The 95% confidence interval of agreement of the Bland-Altman plot encompassed 96% of the difference between LM and PX for pBHB and 95% for sBHB. The mean difference for pBHB was -0.50±0.25mmol, and that for sBHB was -0.63±0.41mmol. The highest Se and Sp for PX were achieved when the threshold for ketosis was set to 1.8mmol/L for pBHB and 2.1mmol/L for sBHB. The area under the ROC curve was 0.97 for pBHB and 0.96 for sBHB. The negative bias shown by the Bland-Altman plots suggested that PX yielded higher pBHB and sBHB concentrations than the LM. However, the excellent test characteristics and area under the ROC curve close to 1 indicated that PX at the adjusted thresholds was able to accurately classify between samples <1.2mmol/L and those ≥1.2mmol/L based on the gold standard test. Copyright © 2015 American Dairy Science Association. Published by Elsevier Inc. All rights reserved.

  16. A rapid UPLC-MS/MS assay for eicosanoids in human plasma: Application to evaluate niacin responsivity.

    PubMed

    Miller, Tricia M; Poloyac, Samuel M; Anderson, Kacey B; Waddell, Brooke L; Messamore, Erik; Yao, Jeffrey K

    2017-01-18

    A rapid and sensitive method using ultra-performance liquid chromatography-tandem mass spectrometry (UPLC-MS/MS) was developed to simultaneously quantify hydroxyeicosatetraenoic (HETE), dihydroxyeicosatrienoic (DiHETrE), epoxyeicosatrienoic acid (EET), and prostaglandin metabolites of arachidonic acid in human plasma. Sample preparation consisted of solid phase extraction with Oasis HLB (30mg) cartridges for all metabolites. Separation of HETEs, EETs, and DiHETrEs was achieved on an Acquity UPLC BEH C18, 1.7µm (100×2.1mm) reversed-phase column (Waters Corp, Millford, MA) with negative electrospray ionization mass spectrometric detection. A second injection of the same extracted sample allowed for separation and assessment of prostaglandin metabolites under optimized UPLC-MS/MS conditions. Additionally, the endogenous levels of these metabolites in five different matrices were determined in order to select the optimal matrix for assay development. Human serum albumin was shown to have the least amount of endogenous metabolites, a recovery efficiency of 79-100% and a matrix effect of 71 - 100%. Linear calibration curves ranging from 0.416 to 66.67ng/ml were validated. Inter-assay and intra-assay variance was less than 15% at most concentrations. This method was successfully applied to quantify metabolite levels in plasma samples of healthy control subjects receiving niacin administration to evaluate the association between niacin administration and eicosanoid plasma level response. Published by Elsevier Ltd.

  17. Validation of Roche LightCycler Epstein-Barr virus quantification reagents in a clinical laboratory setting.

    PubMed

    Gulley, Margaret L; Fan, Hongxin; Elmore, Sandra H

    2006-11-01

    Epstein-Barr virus (EBV) is associated with a wide range of benign and malignant diseases, including infectious mononucleosis, lymphoma, posttransplant lymphoproliferative disorder, and nasopharyngeal carcinoma. Measurement of EBV viral load in plasma is increasingly used for rapid assessment of disease status. We evaluated the performance characteristics of an EBV polymerase chain reaction assay that uses commercial reagents and instruments from Roche Diagnostics (Indianapolis, IN). DNA was extracted from plasma using a MagNaPure instrument, and viral load was measured by real-time polymerase chain reaction on a LightCycler. Analyte-specific reagents included primers and hybridization probes targeting the EBV LMP2 gene and a spiked control sequence. Accuracy and reproducibility were established using DNA from three cell lines. The assay was sensitive to approximately 750 copies of EBV DNA per milliliter of plasma and was linear across at least four orders of magnitude. The assay detected EBV DNA in three of five samples from nasopharyngeal carcinoma patients, seven of nine infectious mononucleosis samples, and 34/34 samples from immunosuppressed patients with clinically significant EBV-related disease, whereas EBV DNA was undetectable in plasma from 21 individuals without EBV-related disease. In conclusion, this LightCycler EBV assay is rapid, sensitive, and linear for quantifying EBV viral load. The assay appears to be useful for measuring clinically significant EBV levels in immunodeficient patients.

  18. Radioimmunoassay of erythropoietin: circulating levels in normal and polycythemic human beings

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Garcia, J.F.; Ebbe, S.N.; Hollander, L.

    1982-05-01

    Techniques are described in detail for the RIA of human Ep in unextracted plasma or serum. With 100 ..mu..l of sample, the assay is sensitive at an Ep concentration of approximately 4 mU/ml, and when required, the sensitivity can be increased to 0.4 mU/ml, a range considerably less than the concentration observed in normal human beings. This is approximately 100 times more sensitive than existing in vivo bioassays for this hormone. Studies concerned with the validation of the Ep RIA show a high degree of correlation with the polycythemic mouse bioassay. Dilutions of a variety of human serum samples showmore » a parallel relationship with the standard reference preparation for Ep. Validation of the RIA is further confirmed by observations of appropriate increases or decreases of circulating Ep levels in physiological and clinical conditions known to be associated with stimulation or suppression of Ep secretion. Significantly different mean serum concentrations of 17.2 mU/ml for normal male subjects and 18.8 mU/ml for normal female subjects were observed. Mean plasma Ep concentrations in patients with polycythemia vera are significantly decreased, and those of patients with secondary polycythemia are significantly increased as compared to plasma levels in normal subjects. These results demonstrate an initial practical value of the Ep RA in the hematology clinic, which will most certainly be expanded with its more extensive use.« less

  19. miR-22-5p revealed as a potential biomarker involved in the acute phase of myocardial infarction via profiling of circulating microRNAs.

    PubMed

    Maciejak, Agata; Kiliszek, Marek; Opolski, Grzegorz; Segiet, Agnieszka; Matlak, Krzysztof; Dobrzycki, Slawomir; Tulacz, Dorota; Sygitowicz, Grazyna; Burzynska, Beata; Gora, Monika

    2016-09-01

    Acute myocardial infarction (AMI) is a life-threatening episode of coronary artery disease. Recently, circulating myocardial-derived microRNAs (miRNAs) have been reported as potential biomarkers of infarction. The present study aimed to identify differentially expressed miRNAs in patients with ST-segment elevation myocardial infarction that could be potentially dysregulated in response to early myocardial damage. miRNA expression profile analysis was performed using the Serum/Plasma Focus miRNA Polymerase Chain Reaction (PCR) panel of Exiqon A/S (Vedbaek, Denmark) on plasma samples of patients on the first day of AMI (admission) and on samples from the identical patients collected six months following AMI. Selected miRNAs were validated by reverse transcription‑quantitative PCR (RT‑qPCR) using independent patients with AMI and a control group of patients with a stable coronary artery disease. Thirty‑two species of plasma miRNA were differentially expressed (P<0.05) on admission compared with six months following AMI. Subsequent validation in an independent patient group confirmed that miR‑133b and miR‑22‑5p were significantly up‑regulated in the serum of patients with AMI. The receiver operating characteristic (ROC) curve analysis demonstrated a diagnostic utility for miR-22-5p, which has not previously been reported to be associated with AMI. Among the selected miRNAs, miR‑22‑5p represents a novel promising biomarker for the diagnosis of AMI.

  20. Validated method to measure yakuchinone A in plasma by LC-MS/MS and its application to a pharmacokinetic study in rats

    PubMed Central

    2014-01-01

    Background Yakuchinone A has a plethora of beneficial biological effects. However, the pharmacokinetic (PK) data of yakuchinone A still remain unknown so far. Furthermore, the quantification of yakuchinone A in biological samples has not been reported in the literature. Therefore, in the present study we aimed to develop a new method for the fast, efficient and accurate assessment of yakuchinone A concentration in plasma, as a means for facilitating the PK evaluation of yakuchinone A. Results A liquid chromatography-electrospray ionization-tandem mass spectrometry (LC-ESI-MS/MS) method was developed and validated for the determination of yakuchinone A in rat plasma. Mass spectrometric and chromatographic conditions were optimized. Plasma samples were pretreated by protein precipitation with methanol. LC separation was performed on a Phenomenex Luna C18 column with gradient elution using a mobile phase consisting of methanol–water containing 0.5 mM formic acid (HCOOH) at a flow rate of 0.28 mL/min. ESI-MS spectra were acquired in positive ion multiple reaction monitoring mode (MRM). The precursor-to-product ion pairs used for MRM of yakuchinone A and yakuchinone B were m/z 313.1 → 137.0 and 311.2 → 117.1, respectively. Low concentration of HCOOH reduced the ion suppression caused by matrix components and clearly improved the analytical sensitivity. Yakuchinone A showed good linearity over a wide concentration range (r > 0.99). The accuracy, precision, stability and linearity were found to be within the acceptable criteria. This new method was successfully applied to analyze the rat plasma concentration of parent yakuchinone A after a single oral administration of SuoQuan capsules. Low systemic exposure to parent yakuchinone A was observed. Conclusion The proposed method is sensitive and reliable. It is hoped that this new method will prove useful for the future PK studies. PMID:24422995

  1. A specific and sensitive HPLC-MS/MS micromethod for milrinone plasma levels determination after inhalation in cardiac patients.

    PubMed

    Gavra, Paul; Nguyen, Anne Q-N; Theoret, Yves; Litalien, Catherine; Denault, André Y; Varin, France

    2014-10-01

    Milrinone administered through inhalation is an emerging method aimed at specifically reducing pulmonary hypertension without affecting systemic pressures. Its administration has been shown to be useful both in patients undergoing cardiac surgery and for persistent pulmonary hypertension of the newborn. These populations are prone to receive many concomitant medications and/or blood sampling may require a low volume quantification method. To address these issues in view of pharmacokinetic studies, this article aims to develop and validate a specific and sensitive analytical assay using high performance liquid chromatography (HPLC) and tandem mass spectrometry (MS/MS) detection for the quantification of milrinone plasma concentrations after inhalation in patients undergoing cardiac surgery. Plasma samples (50 μL) were extracted using ethyl acetate. Milrinone was separated on a C18 analytical column at 50°C. The mobile phase consisted of methanol and 10 mM ammonium acetate (45:55 vol/vol). The electrospray was operated in the negative ionization mode and monitored the following mass transitions: m/z 212.1 → 140.0 at 36 eV for milrinone and m/z 252.1 → 156.1 at 32 eV for olprinone. Calibration curves followed a quadratic regression in the concentration range of 0.3125-640 ng/mL. The lower limit of quantification is 0.3125 ng/mL and is based on a low plasma volume of 50 μL. Mean drug recovery and accuracy were ≥72.3% and 96.0%, respectively. Intraday and interday precision coefficient of variation (%) was ≤7.4% and ≤11.5%, respectively. The specificity allowed milrinone quantification in the multidrug administration conditions of cardiopulmonary bypass. This validated micromethod proved to be highly sensitive and specific while using a low volume of plasma. Its low volume and its lower limit of quantification indicate that this approach is suitable for further characterization of milrinone pharmacokinetics in both adults (inhalation) and neonates.

  2. Clinical validation of a novel diagnostic HIV-2 total nucleic acid qualitative assay using the Abbott m2000 platform: Implications for complementary HIV-2 nucleic acid testing for the CDC 4th generation HIV diagnostic testing algorithm.

    PubMed

    Chang, Ming; Wong, Audrey J S; Raugi, Dana N; Smith, Robert A; Seilie, Annette M; Ortega, Jose P; Bogusz, Kyle M; Sall, Fatima; Ba, Selly; Seydi, Moussa; Gottlieb, Geoffrey S; Coombs, Robert W

    2017-01-01

    The 2014 CDC 4th generation HIV screening algorithm includes an orthogonal immunoassay to confirm and discriminate HIV-1 and HIV-2 antibodies. Additional nucleic acid testing (NAT) is recommended to resolve indeterminate or undifferentiated HIV seroreactivity. HIV-2 NAT requires a second-line assay to detect HIV-2 total nucleic acid (TNA) in patients' blood cells, as a third of untreated patients have undetectable plasma HIV-2 RNA. To validate a qualitative HIV-2 TNA assay using peripheral blood mononuclear cells (PBMC) from HIV-2-infected Senegalese study participants. We evaluated the assay precision, sensitivity, specificity, and diagnostic performance of an HIV-2 TNA assay. Matched plasma and PBMC samples were collected from 25 HIV-1, 30 HIV-2, 8 HIV-1/-2 dual-seropositive and 25 HIV seronegative individuals. Diagnostic performance was evaluated by comparing the outcome of the TNA assay to the results obtained by the 4th generation HIV screening and confirmatory immunoassays. All PBMC from 30 HIV-2 seropositive participants tested positive for HIV-2 TNA including 23 patients with undetectable plasma RNA. Of the 30 matched plasma specimens, one was HIV non-reactive. Samples from 50 non-HIV-2 infected individuals were confirmed as non-reactive for HIV-2 Ab and negative for HIV-2 TNA. The agreement between HIV-2 TNA and the combined immunoassay results was 98.8% (79/80). Furthermore, HIV-2 TNA was detected in 7 of 8 PBMC specimens from HIV-1/HIV-2 dual-seropositive participants. Our TNA assay detected HIV-2 DNA/RNA in PBMC from serologically HIV-2 reactive, HIV indeterminate or HIV undifferentiated individuals with undetectable plasma RNA, and is suitable for confirming HIV-2 infection in the HIV testing algorithm. Copyright © 2016 Elsevier B.V. All rights reserved.

  3. Affinity Proteomics for Fast, Sensitive, Quantitative Analysis of Proteins in Plasma.

    PubMed

    O'Grady, John P; Meyer, Kevin W; Poe, Derrick N

    2017-01-01

    The improving efficacy of many biological therapeutics and identification of low-level biomarkers are driving the analytical proteomics community to deal with extremely high levels of sample complexity relative to their analytes. Many protein quantitation and biomarker validation procedures utilize an immunoaffinity enrichment step to purify the sample and maximize the sensitivity of the corresponding liquid chromatography tandem mass spectrometry measurements. In order to generate surrogate peptides with better mass spectrometric properties, protein enrichment is followed by a proteolytic cleavage step. This is often a time-consuming multistep process. Presented here is a workflow which enables rapid protein enrichment and proteolytic cleavage to be performed in a single, easy-to-use reactor. Using this strategy Klotho, a low-abundance biomarker found in plasma, can be accurately quantitated using a protocol that takes under 5 h from start to finish.

  4. Lipidomic analysis of biological samples: Comparison of liquid chromatography, supercritical fluid chromatography and direct infusion mass spectrometry methods.

    PubMed

    Lísa, Miroslav; Cífková, Eva; Khalikova, Maria; Ovčačíková, Magdaléna; Holčapek, Michal

    2017-11-24

    Lipidomic analysis of biological samples in a clinical research represents challenging task for analytical methods given by the large number of samples and their extreme complexity. In this work, we compare direct infusion (DI) and chromatography - mass spectrometry (MS) lipidomic approaches represented by three analytical methods in terms of comprehensiveness, sample throughput, and validation results for the lipidomic analysis of biological samples represented by tumor tissue, surrounding normal tissue, plasma, and erythrocytes of kidney cancer patients. Methods are compared in one laboratory using the identical analytical protocol to ensure comparable conditions. Ultrahigh-performance liquid chromatography/MS (UHPLC/MS) method in hydrophilic interaction liquid chromatography mode and DI-MS method are used for this comparison as the most widely used methods for the lipidomic analysis together with ultrahigh-performance supercritical fluid chromatography/MS (UHPSFC/MS) method showing promising results in metabolomics analyses. The nontargeted analysis of pooled samples is performed using all tested methods and 610 lipid species within 23 lipid classes are identified. DI method provides the most comprehensive results due to identification of some polar lipid classes, which are not identified by UHPLC and UHPSFC methods. On the other hand, UHPSFC method provides an excellent sensitivity for less polar lipid classes and the highest sample throughput within 10min method time. The sample consumption of DI method is 125 times higher than for other methods, while only 40μL of organic solvent is used for one sample analysis compared to 3.5mL and 4.9mL in case of UHPLC and UHPSFC methods, respectively. Methods are validated for the quantitative lipidomic analysis of plasma samples with one internal standard for each lipid class. Results show applicability of all tested methods for the lipidomic analysis of biological samples depending on the analysis requirements. Copyright © 2017 Elsevier B.V. All rights reserved.

  5. ESR1 Methylation: A Liquid Biopsy-Based Epigenetic Assay for the Follow-up of Patients with Metastatic Breast Cancer Receiving Endocrine Treatment.

    PubMed

    Mastoraki, Sophia; Strati, Areti; Tzanikou, Eleni; Chimonidou, Maria; Politaki, Eleni; Voutsina, Alexandra; Psyrri, Amanda; Georgoulias, Vassilis; Lianidou, Evi

    2018-03-15

    Purpose: Liquid biopsy provides real-time monitoring of tumor evolution and response to therapy through analysis of circulating tumor cells (CTCs) and plasma-circulating tumor DNA (ctDNA). ESR1 epigenetic silencing potentially affects response to endocrine treatment. We evaluated ESR1 methylation in CTCs and paired plasma ctDNA. We evaluated ESR1 methylation in CTCs and paired plasma ctDNA as a potential biomarker for response to everolimus/exemestane treatment. Experimental Design: A highly sensitive and specific real-time MSP assay for ESR1 methylation was developed and validated in (i) 65 primary breast tumors formalin-fixed paraffin-embedded (FFPE), (ii) EpCAM + CTC fractions (122 patients and 30 healthy donors; HD), (iii) plasma ctDNA (108 patients and 30HD), and (iv) in CTCs (CellSearch) and in paired plasma ctDNA for 58 patients with breast cancer. ESR1 methylation status was investigated in CTCs isolated from serial peripheral blood samples of 19 patients with ER + /HER2 - advanced breast cancer receiving everolimus/exemestane. Results: ESR1 methylation was detected in: (i) 25/65 (38.5%) FFPEs, (ii) EpCAM + CTC fractions : 26/112 (23.3%) patients and 1/30 (3.3%) HD, and (iii) plasma ctDNA: 8/108 (7.4%) patients and 1/30 (3.3%) HD. ESR1 methylation was highly concordant in 58 paired DNA samples, isolated from CTCs (CellSearch) and corresponding plasma. In serial peripheral blood samples of patients treated with everolimus/exemestane, ESR1 methylation was observed in 10/36 (27.8%) CTC-positive samples, and was associated with lack of response to treatment ( P = 0.023, Fisher exact test). Conclusions: We report for the first time the detection of ESR1 methylation in CTCs and a high concordance with paired plasma ctDNA. ESR1 methylation in CTCs was associated with lack of response to everolimus/exemestane regimen. ESR1 methylation should be further evaluated as a potential liquid biopsy-based biomarker. Clin Cancer Res; 24(6); 1500-10. ©2017 AACR . ©2017 American Association for Cancer Research.

  6. Quantitation of pilsicainide in microscale samples of human biological fluids using liquid chromatography-tandem mass spectrometry.

    PubMed

    Shimizu, Mikiko; Hashiguchi, Masayuki; Shiga, Tsuyoshi; Nakamura, Koichi; Tamura, Hiro-omi; Mochizuki, Mayumi

    2015-03-15

    This paper describes a sensitive, reliable method to determine pilsicainide (PLC) levels in microscale sample volumes of human biological fluids using liquid chromatography-tandem mass spectrometry (LC-MS/MS) with electrospray ionization (ESI). PLC and quinidine as an internal standard were extracted with diethylether from 0.1mL of alkalinized biological fluids. The extract was injected into an analytical column (l-column 2 ODS, 75mm×2.1mm i.d.). The mobile phase for separation consisted of 5mM ammonium acetate (pH 4.5)/methanol (4:1, v/v) and was delivered at a flow rate of 0.2mL/min. The drift voltage was 100V. The sampling aperture was heated at 120°C and the shield temperature was 260°C. The ion transitions used to monitor analytes were m/z 273→m/z 110 for PLC and m/z 325→m/z 79 for quinidine. The total time for chromatographic separation was less than 8min. The validated concentration ranges of this method for PLC were 5-2000ng/mL in plasma, 5-500ng/mL in ultrafiltered plasma solution, and 25-2000ng/mL in urine. Mean recoveries of PLC in plasma, ultrafiltered plasma solution, and urine were 93.2-99.7%, 91.4-100.6%, and 93.9-104.7%, respectively. Intra- and interday coefficients of variation for PLC were less than 6.0% and 4.3% in plasma, 6.1% and 3.7% in ultrafiltered plasma solution, and 5.4% and 2.5% in urine at the above concentration ranges, respectively. The lower limit of quantification for PLC in plasma, ultrafiltered plasma solution, and urine were 5ng/mL, 5ng/mL, and 25ng/mL, respectively. This method can be applied to pharmacokinetic study and therapeutic drug monitoring in special populations such as neonates, infants, and the elderly by making effective use of residual samples used for general clinical laboratory testing. Copyright © 2015 Elsevier B.V. All rights reserved.

  7. Simultaneous quantification of fentanyl, sufentanil, cefazolin, doxapram and keto-doxapram in plasma using liquid chromatography - tandem mass spectrometry.

    PubMed

    Flint, Robert B; Bahmany, Soma; van der Nagel, Bart C H; Koch, Birgit C P

    2018-05-16

    A simple and specific UPLC-MS/MS method was developed and validated for simultaneous quantification of fentanyl, sufentanil, cefazolin, doxapram and its active metabolite keto-doxapram. The internal standard was fentanyl-d5 for all analytes. Chromatographic separation was achieved with a reversed phase Acquity UPLC HSS T3 column with a run-time of only 5.0 minutes per injected sample. Gradient elution was performed with a mobile phase consisting of ammonium acetate, formic acid in Milli-Q ultrapure water or in methanol with a total flow rate of 0.4 mL minute -1 . A plasma volume of only 50 μL was required to achieve both adequate accuracy and precision. Calibration curves of all 5 analytes were linear. All analytes were stable for at least 48 hours in the autosampler. The method was validated according to US Food and Drug Administration guidelines. This method allows quantification of fentanyl, sufentanil, cefazolin, doxapram and keto-doxapram, which serves purposes for research, as well as therapeutic drug monitoring, if applicable. The strength of this method is the combination of a small sample volume, a short run-time, a deuterated internal standard, an easy sample preparation method and the ability to simultaneously quantify all analytes in one run. This article is protected by copyright. All rights reserved.

  8. Targeted quantitative analysis of Streptococcus pyogenes virulence factors by multiple reaction monitoring.

    PubMed

    Lange, Vinzenz; Malmström, Johan A; Didion, John; King, Nichole L; Johansson, Björn P; Schäfer, Juliane; Rameseder, Jonathan; Wong, Chee-Hong; Deutsch, Eric W; Brusniak, Mi-Youn; Bühlmann, Peter; Björck, Lars; Domon, Bruno; Aebersold, Ruedi

    2008-08-01

    In many studies, particularly in the field of systems biology, it is essential that identical protein sets are precisely quantified in multiple samples such as those representing differentially perturbed cell states. The high degree of reproducibility required for such experiments has not been achieved by classical mass spectrometry-based proteomics methods. In this study we describe the implementation of a targeted quantitative approach by which predetermined protein sets are first identified and subsequently quantified at high sensitivity reliably in multiple samples. This approach consists of three steps. First, the proteome is extensively mapped out by multidimensional fractionation and tandem mass spectrometry, and the data generated are assembled in the PeptideAtlas database. Second, based on this proteome map, peptides uniquely identifying the proteins of interest, proteotypic peptides, are selected, and multiple reaction monitoring (MRM) transitions are established and validated by MS2 spectrum acquisition. This process of peptide selection, transition selection, and validation is supported by a suite of software tools, TIQAM (Targeted Identification for Quantitative Analysis by MRM), described in this study. Third, the selected target protein set is quantified in multiple samples by MRM. Applying this approach we were able to reliably quantify low abundance virulence factors from cultures of the human pathogen Streptococcus pyogenes exposed to increasing amounts of plasma. The resulting quantitative protein patterns enabled us to clearly define the subset of virulence proteins that is regulated upon plasma exposure.

  9. Validated method for determination of bromopride in human plasma by liquid chromatography--electrospray tandem mass spectrometry: application to the bioequivalence study.

    PubMed

    Nazare, P; Massaroti, P; Duarte, L F; Campos, D R; Marchioretto, M A M; Bernasconi, G; Calafatti, S; Barros, F A P; Meurer, E C; Pedrazzoli, J; Moraes, L A B

    2005-09-01

    A simple, sensitive and specific liquid chromatography-tandem mass spectrometry method for the quantification of bromopride I in human plasma is presented. Sample preparation consisted of the addition of procainamide II as the internal standard, liquid-liquid extraction in alkaline conditions using hexane-ethyl acetate (1 : 1, v/v) as the extracting solvent, followed by centrifugation, evaporation of the solvent and sample reconstitution in acetonitrile. Both I and II (internal standard, IS) were analyzed using a C18 column and the mobile-phase acetonitrile-water (formic acid 0.1%). The eluted compounds were monitored using electrospray tandem mass spectrometry. The analyses were carried out by multiple reaction monitoring (MRM) using the parent-to-daughter combinations of m/z 344.20 > 271.00 and m/z 236.30 > 163.10. The areas of peaks from analyte and IS were used for quantification of I. The achieved limit of quantification was 1.0 ng/ml and the assay exhibited a linear dynamic range of 1-100.0 ng/ml and gave a correlation coefficient (r) of 0.995 or better. Validation results on linearity, specificity, accuracy, precision and stability, as well as application to the analysis of samples taken up to 24 h after oral administration of 10 mg of I in healthy volunteers demonstrated the applicability to bioequivalence studies.

  10. A blood-based proteomic classifier for the molecular characterization of pulmonary nodules.

    PubMed

    Li, Xiao-jun; Hayward, Clive; Fong, Pui-Yee; Dominguez, Michel; Hunsucker, Stephen W; Lee, Lik Wee; McLean, Matthew; Law, Scott; Butler, Heather; Schirm, Michael; Gingras, Olivier; Lamontagne, Julie; Allard, Rene; Chelsky, Daniel; Price, Nathan D; Lam, Stephen; Massion, Pierre P; Pass, Harvey; Rom, William N; Vachani, Anil; Fang, Kenneth C; Hood, Leroy; Kearney, Paul

    2013-10-16

    Each year, millions of pulmonary nodules are discovered by computed tomography and subsequently biopsied. Because most of these nodules are benign, many patients undergo unnecessary and costly invasive procedures. We present a 13-protein blood-based classifier that differentiates malignant and benign nodules with high confidence, thereby providing a diagnostic tool to avoid invasive biopsy on benign nodules. Using a systems biology strategy, we identified 371 protein candidates and developed a multiple reaction monitoring (MRM) assay for each. The MRM assays were applied in a three-site discovery study (n = 143) on plasma samples from patients with benign and stage IA lung cancer matched for nodule size, age, gender, and clinical site, producing a 13-protein classifier. The classifier was validated on an independent set of plasma samples (n = 104), exhibiting a negative predictive value (NPV) of 90%. Validation performance on samples from a nondiscovery clinical site showed an NPV of 94%, indicating the general effectiveness of the classifier. A pathway analysis demonstrated that the classifier proteins are likely modulated by a few transcription regulators (NF2L2, AHR, MYC, and FOS) that are associated with lung cancer, lung inflammation, and oxidative stress networks. The classifier score was independent of patient nodule size, smoking history, and age, which are risk factors used for clinical management of pulmonary nodules. Thus, this molecular test provides a potential complementary tool to help physicians in lung cancer diagnosis.

  11. Methods to Detect Nitric Oxide and its Metabolites in Biological Samples

    PubMed Central

    Bryan, Nathan S.; Grisham, Matthew B.

    2007-01-01

    Nitric oxide (NO) methodology is a complex and often confusing science and the focus of many debates and discussion concerning NO biochemistry. NO is involved in many physiological processes including regulation of blood pressure, immune response and neural communication. Therefore its accurate detection and quantification is critical to understanding health and disease. Due to the extremely short physiological half life of this gaseous free radical, alternative strategies for the detection of reaction products of NO biochemistry have been developed. The quantification of NO metabolites in biological samples provides valuable information with regards to in vivo NO production, bioavailability and metabolism. Simply sampling a single compartment such as blood or plasma may not always provide an accurate assessment of whole body NO status, particularly in tissues. Therefore, extrapolation of plasma or blood NO status to specific tissues of interest is no longer a valid approach. As a result, methods continue to be developed and validated which allow the detection and quantification of NO and NO-related products/metabolites in multiple compartments of experimental animals in vivo. The methods described in this review is not an exhaustive or comprehensive discussion of all methods available for the detection of NO but rather a description of the most commonly used and practical methods which allow accurate and sensitive quantification of NO products/metabolites in multiple biological matrices under normal physiological conditions. PMID:17664129

  12. Field Evaluation of a Broadly Sensitive HIV-1 In-House Genotyping Assay for Use with both Plasma and Dried Blood Spot Specimens in a Resource-Limited Country

    PubMed Central

    Inzaule, Seth; Yang, Chunfu; Kasembeli, Alex; Nafisa, Lillian; Okonji, Jully; Oyaro, Boaz; Lando, Richard; Mills, Lisa A.; Laserson, Kayla; Thomas, Timothy; Nkengasong, John

    2013-01-01

    HIV-1 drug resistance (HIVDR) assays are important tools in clinical management of HIV-infected patients on antiretroviral therapy (ART) and surveillance of drug-resistant variants at population levels. The high cost associated with commercial assays hinders their use in resource-limited settings. We adopted and validated a low-cost in-house assay using 68 matched plasma and dried blood spot (DBS) samples with a median viral load (VL) of 58,187 copies/ml, ranging from 253 to 3,264,850 against the commercial assay ViroSeq. Results indicated that the in-house assay not only had a higher plasma genotyping rate than did ViroSeq (94% versus 78%) but also was able to genotype 89.5% (51/57) of the matched DBS samples with VLs of ≥1,000 copies/ml. The sensitivity in detecting DR mutations by the in-house assay was 98.29% (95% confidence interval [CI], 97.86 to 98.72) on plasma and 96.54 (95% CI, 95.93 to 97.15) on DBS, and the specificity was 99.97% (95% CI, 99.91 to 100.00) for both sample types compared to ViroSeq. The minor DR mutation differences detected by the in-house assay against ViroSeq did not result in clinical significance. In addition, cost analysis showed that the in-house assay could reduce the genotyping cost by about 60% for both plasma and DBS compared to ViroSeq. This field condition evaluation highlights the potential utility of a cost-effective, subtype-independent, in-house genotyping assay using both plasma and DBS specimens for HIVDR clinical monitoring and population-based surveillance in resource-limited settings. PMID:23224100

  13. Phenolic and microbial-targeted metabolomics to discovering and evaluating wine intake biomarkers in human urine and plasma.

    PubMed

    Urpi-Sarda, Mireia; Boto-Ordóñez, María; Queipo-Ortuño, María Isabel; Tulipani, Sara; Corella, Dolores; Estruch, Ramon; Tinahones, Francisco J; Andres-Lacueva, Cristina

    2015-09-01

    The discovery of biomarkers of intake in nutritional epidemiological studies is essential in establishing an association between dietary intake (considering their bioavailability) and diet-related risk factors for diseases. The aim is to study urine and plasma phenolic and microbial profile by targeted metabolomics approach in a wine intervention clinical trial for discovering and evaluating food intake biomarkers. High-risk male volunteers (n = 36) were included in a randomized, crossover intervention clinical trial. After a washout period, subjects received red wine or gin, or dealcoholized red wine over four weeks. Fasting plasma and 24-h urine were collected at baseline and after each intervention period. A targeted metabolomic analysis of 70 host and microbial phenolic metabolites was performed using ultra performance liquid chromatography-tandem mass spectrometer (UPLC-MS/MS). Metabolites were subjected to stepwise logistic regression to establish prediction models and received operation curves were performed to evaluate biomarkers. Prediction models based mainly on gallic acid metabolites, obtained sensitivity, specificity and area under the curve (AUC) for the training and validation sets of between 91 and 98% for urine and between 74 and 91% for plasma. Resveratrol, ethylgallate and gallic acid metabolite groups in urine samples also resulted in being good predictors of wine intake (AUC>87%). However, lower values for metabolites were obtained in plasma samples. The highest correlations between fasting plasma and urine were obtained for the prediction model score (r = 0.6, P<0.001), followed by gallic acid metabolites (r = 0.5-0.6, P<0.001). This study provides new insights into the discovery of food biomarkers in different biological samples. © 2015 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  14. Affinity proteomic profiling of plasma for proteins associated to area-based mammographic breast density.

    PubMed

    Byström, Sanna; Eklund, Martin; Hong, Mun-Gwan; Fredolini, Claudia; Eriksson, Mikael; Czene, Kamila; Hall, Per; Schwenk, Jochen M; Gabrielson, Marike

    2018-02-14

    Mammographic breast density is one of the strongest risk factors for breast cancer, but molecular understanding of how breast density relates to cancer risk is less complete. Studies of proteins in blood plasma, possibly associated with mammographic density, are well-suited as these allow large-scale analyses and might shed light on the association between breast cancer and breast density. Plasma samples from 1329 women in the Swedish KARMA project, without prior history of breast cancer, were profiled with antibody suspension bead array (SBA) assays. Two sample sets comprising 729 and 600 women were screened by two different SBAs targeting a total number of 357 proteins. Protein targets were selected through searching the literature, for either being related to breast cancer or for being linked to the extracellular matrix. Association between proteins and absolute area-based breast density (AD) was assessed by quantile regression, adjusting for age and body mass index (BMI). Plasma profiling revealed linear association between 20 proteins and AD, concordant in the two sets of samples (p < 0.05). Plasma levels of seven proteins were positively associated and 13 proteins negatively associated with AD. For eleven of these proteins evidence for gene expression in breast tissue existed. Among these, ABCC11, TNFRSF10D, F11R and ERRF were positively associated with AD, and SHC1, CFLAR, ACOX2, ITGB6, RASSF1, FANCD2 and IRX5 were negatively associated with AD. Screening proteins in plasma indicates associations between breast density and processes of tissue homeostasis, DNA repair, cancer development and/or progression in breast cancer. Further validation and follow-up studies of the shortlisted protein candidates in independent cohorts will be needed to infer their role in breast density and its progression in premenopausal and postmenopausal women.

  15. Simultaneous quantitation of delamanid (OPC-67683) and its eight metabolites in human plasma using UHPLC-MS/MS.

    PubMed

    Meng, Min; Smith, Benjamin; Johnston, Brad; Carter, Spencer; Brisson, Jerry; Roth, Sharin E

    2015-10-01

    Delamanid (OPC-67683) is a novel nitro-dihydroimidazo-oxazole derivative that is being developed by Otsuka Pharmaceutical Co., Ltd., Japan (referred to as Otsuka hereafter) for the treatment of tuberculosis (TB). An ultra-high performance liquid chromatographic-tandem mass spectrometry (UHPLC-MS/MS) method has been developed and validated for the determination of OPC-67683 and its eight metabolites, DM-6704, DM-6705, DM-6706, DM-6717, DM-6718, DM-6720, DM-6721 and DM-6722 in human plasma to support regulated clinical development. During method development several technical challenges such as poor chromatography, separation of structural isomers, conversion of the analytes, instability in matrix and long cycle time were encountered and overcome. A protein precipitation extraction (PPE) was used to extract plasma samples (50μL) and the resulting extracts were analyzed using reversed phase UHPLC-MS/MS with a electrospray (ESI) and selected reaction monitoring (SRM). The method was fully validated over the calibration curve range of 1.00-500ng/mL for all nine analytes with linear regression and 1/x(2) weighting according to regulatory guidance for bioanalysis. Based on three inter-day precision and accuracy runs, the between-run % relative standard deviation (RSD) for all nine analytes varied from 0.0 to 11.9% and the accuracy ranged from 92.7% to 102.5% of nominal at all quality controls (QC) concentrations, including the lower limit of quantitation (LLOQ) QC at 1.00ng/mL. The extraction recovery of OPC-67683 and its eight metabolites were above 95%. Various short term and long term solution and matrix stability were established including the stability of OPC-67683 and its eight metabolites in human plasma for 708 days at -70°C. Although this method has been used to support regulated clinic studies during the last decade and over ten thousand samples have been analyzed, this is the first time that the method development process and validation data have been published. Copyright © 2015 Elsevier B.V. All rights reserved.

  16. 68Ga-EDTA PET/CT imaging and plasma clearance for glomerular filtration rate quantification: comparison to conventional 51Cr-EDTA.

    PubMed

    Hofman, Michael; Binns, David; Johnston, Val; Siva, Shankar; Thompson, Mick; Eu, Peter; Collins, Marnie; Hicks, Rodney J

    2015-03-01

    Glomerular filtration rate (GFR) can accurately be determined using (51)Cr-ethylenediaminetetraacetic acid (EDTA) plasma clearance counting but is time-consuming and requires technical skills and equipment not always available in imaging departments. (68)Ga-EDTA can be readily available using an onsite generator, and PET/CT enables both imaging of renal function and accurate camera-based quantitation of clearance of activity from blood and its appearance in the urine. This study aimed to assess agreement between (68)Ga-EDTA GFR ((68)Ga-GFR) and (51)Cr-EDTA GFR ((51)Cr-GFR), using serial plasma sampling and PET imaging. (68)Ga-EDTA and (51)Cr-EDTA were injected concurrently in 31 patients. Dynamic PET/CT encompassing the kidneys was acquired for 10 min followed by 3 sequential 3-min multibed step acquisitions from kidneys to bladder. PET quantification was performed using renal activity at 1-2 min (PETinitial), renal excretion at 2-10 min (PETearly), and, subsequently, urinary excretion into the collecting system and bladder (PETlate). Plasma sampling at 2, 3, and 4 h was performed, with (68)Ga followed by (51)Cr counting after positron decay. The level of agreement for GFR determination was calculated using a Bland-Altman plot and Pearson correlation coefficient (PCC). (51)Cr-GFR ranged from 10 to 220 mL/min (mean, 85 mL/min). There was good agreement between (68)Ga-GFR and (51)Cr-GFR using serial plasma sampling, with a Bland-Altman bias of -14 ± 20 mL/min and a PCC of 0.94 (95% confidence interval, 0.88-0.97). Of the 3 methods used for camera-based quantification, the strongest correlation was for plasma sampling-derived GFR with PETlate (PCC of 0.90; 95% confidence interval, 0.80-0.95). (68)Ga-GFR agreed well with (51)Cr-GFR for estimation of GFR using serial plasma counting. PET dynamic imaging provides a method to estimate GFR without plasma sampling, with the additional advantage of enabling renal imaging in a single study. Additional validation in a larger cohort is warranted to further assess utility. © 2015 by the Society of Nuclear Medicine and Molecular Imaging, Inc.

  17. Determination of oxycodone and its major metabolites noroxycodone and oxymorphone by ultra-high-performance liquid chromatography tandem mass spectrometry in plasma and urine: application to real cases.

    PubMed

    Pantano, Flaminia; Brauneis, Stefano; Forneris, Alexandre; Pacifici, Roberta; Marinelli, Enrico; Kyriakou, Chrystalla; Pichini, Simona; Busardò, Francesco Paolo

    2017-08-28

    Oxycodone is a narcotic drug widely used to alleviate moderate and severe acute and chronic pain. Variability in analgesic efficacy could be explained by inter-subject variations in plasma concentrations of parent drug and its active metabolite, oxymorphone. To evaluate patient compliance and to set up therapeutic drug monitoring (TDM), an ultra-high-performance liquid chromatography-tandem mass spectrometry (UHPLC-MS/MS) assay was developed and validated for the parent drug and its major metabolites noroxycodone and oxymorphone. Extraction of analytes from plasma and urine samples was obtained by simple liquid-liquid extraction. The chromatographic separation was achieved with a reversed phase column using a linear gradient elution with two solvents: acetic acid 1% in water and methanol. The separated analytes were detected with a triple quadrupole mass spectrometer operated in multiple reaction monitoring (MRM) mode via positive electrospray ionization (ESI). Separation of analytes was obtained in less than 5 min. Linear calibration curves for all the analytes under investigation in urine and plasma samples showed determination coefficients (r2) equal or higher than 0.990. Mean absolute analytical recoveries were always above 86%. Intra- and inter-assay precision (measured as coefficient of variation, CV%) and accuracy (measured as % error) values were always better than 13%. Limit of detection at 0.06 and 0.15 ng/mL and limit of quantification at 0.2 and 0.5 ng/mL for plasma and urine samples, respectively, were adequate for the purpose of the present study. Rapid extraction, identification and quantification of oxycodone and its metabolites both in urine and plasma by UHPLC-MS/MS assay was tested for its feasibility in clinical samples and provided excellent results for rapid and effective drug testing in patients under oxycodone treatment.

  18. Robotic solid phase extraction and high performance liquid chromatographic analysis of ranitidine in serum or plasma.

    PubMed

    Lloyd, T L; Perschy, T B; Gooding, A E; Tomlinson, J J

    1992-01-01

    A fully automated assay for the analysis of ranitidine in serum and plasma, with and without an internal standard, was validated. It utilizes robotic solid phase extraction with on-line high performance liquid chromatographic (HPLC) analysis. The ruggedness of the assay was demonstrated over a three-year period. A Zymark Py Technology II robotic system was used for serial processing from initial aspiration of samples from original collection containers, to final direct injection onto the on-line HPLC system. Automated serial processing with on-line analysis provided uniform sample history and increased productivity by freeing the chemist to analyse data and perform other tasks. The solid phase extraction efficiency was 94% throughout the assay range of 10-250 ng/mL. The coefficients of variation for within- and between-day quality control samples ranged from 1 to 6% and 1 to 5%, respectively. Mean accuracy for between-day standards and quality control results ranged from 97 to 102% of the respective theoretical concentrations.

  19. Validation of a method for the determination of zolpidem in human plasma using LC with fluorescence detection.

    PubMed

    Ring, P R; Bostick, J M

    2000-04-01

    A sensitive and selective high-performance liquid chromatography (HPLC) method was developed for the determination of zolpidem in human plasma. Zolpidem and the internal standard (trazodone) were extracted from human plasma that had been made basic. The basic sample was loaded onto a conditioned Bond Elut C18 cartridge, rinsed with water and eluted with methanol. Forty microliters were then injected onto the LC system. Separation was achieved on a C18 column (150 x 4.6 mm, 5 microm) with a mobile phase composed of acetonitrile:50 mM potassium phosphate monobasic at pH 6.0 (4:6, v/v). Detection was by fluorescence, with excitation at 254 nm and emission at 400 nm. The retention times of zolpidem and internal standard were approximately 4.7 and 5.3 min, respectively. The LC run time was 8 min. The assay was linear in concentration range 1-400 ng/ml for zolpidem in human plasma. The analysis of quality control samples for zolpidem (3, 30, and 300 ng/ml) demonstrated excellent precision with relative standard deviations (RSD) of 3.7, 4.6, and 3.0%, respectively (n = 18). The method was accurate with all intraday (n = 6) and overall (n = 18) mean concentrations within 5.8% from nominal at all quality control sample concentrations. This method was also performed using a Gilson Aspec XL automated sample processor and autoinjector. The samples were manually fortified with internal standard and made basic. The aspec then performed the solid phase extraction and made injections of the samples onto the LC system. Using the automated procedure for analysis, quality control samples for zolpidem (3, 30, and 300 ng/ml) demonstrated acceptable precision with RSD values of 9.0, 4.9, and 5.1%, respectively (n = 12). The method was accurate with all intracurve (n = 4) and overall (n = 12) mean values being less than 10.8% from nominal at all quality control sample concentrations.

  20. A sensitive LC-MS/MS-based bioanalytical method for quantification of salviaflaside and rosmarinic acid in rat plasma and its application in a pharmacokinetic study.

    PubMed

    Yang, Yimin; Ying, Sha; Li, Te; Zhen, Juan; Chen, Dongmei; Wang, Jianmeng

    2018-04-14

    A selective and sensitive liquid chromatography tandem mass spectrometry method was developed for the simultaneous determination of salviaflaside and rosmarinic acid in rat plasma. Sample preparation was carried out through liquid-liquid extraction with ethyl acetate using curculigoside as internal standard (IS). The analytes were determined by selected reaction monitoring operated in the positive ESI mode. Chromatographic separation was performed on an Agilent Eclipse Plus C 18 column (100 × 4.6 mm, 1.8 μm) with a mobile phase consisting of methanol-water-formic acid (50:50:0.1, v/v/v) at a flow rate of 0.3 mL/min. The run time was 1.9 min per sample and the injection volume was 5 μL. The method had an LLOQ of 1.6 ng/mL for salviaflaside and 0.94 ng/mL for rosmarinic acid in plasma. The linear calibration curves were fitted over the range of 1.6-320 ng/mL for salviaflaside and 0.94-188 ng/mL for rosmarinic acid in plasma with correlation coefficients (r 2 ) >0.99. Intra- and inter-day precisions (relative standard deviation) were < 13.5%, and accuracies (relative error) were between -8.6% and 14.5% for all quality control samples. The method was validated and applied to the pharmacokinetics of salviaflaside and rosmarinic acid in plasma after oral administration of Prunella vulgaris extract to rats. Copyright © 2018 John Wiley & Sons, Ltd.

  1. Development and validation of an ultra-fast and sensitive microflow liquid chromatography-tandem mass spectrometry (MFLC-MS/MS) method for quantification of LSD and its metabolites in plasma and application to a controlled LSD administration study in humans.

    PubMed

    Steuer, Andrea E; Poetzsch, Michael; Stock, Lorena; Eisenbeiss, Lisa; Schmid, Yasmin; Liechti, Matthias E; Kraemer, Thomas

    2017-05-01

    Lysergic acid diethylamide (LSD) is a semi-synthetic hallucinogen that has gained popularity as a recreational drug and has been investigated as an adjunct to psychotherapy. Analysis of LSD represents a major challenge in forensic toxicology due to its instability, low drug concentrations, and short detection windows in biological samples. A new, fast, and sensitive microflow liquid chromatography (MFLC) tandem mass spectrometry method for the validated quantification of LSD, iso-LSD, 2-oxo 3-hydroxy-LSD (oxo-HO-LSD), and N-desmethyl-LSD (nor-LSD) was developed in plasma and applied to a controlled pharmacokinetic (PK) study in humans to test whether LSD metabolites would offer for longer detection windows. Five hundred microlitres of plasma were extracted by solid phase extraction. Analysis was performed on a Sciex Eksigent MFLC system coupled to a Sciex 5500 QTrap. The method was validated according to (inter)-national guidelines. MFLC allowed for separation of the mentioned analytes within 3 minutes and limits of quantification of 0.01 ng/mL. Validation criteria were fulfilled for all analytes. PK data could be calculated for LSD, iso-LSD, and oxo-HO-LSD in all participants. Additionally, hydroxy-LSD (HO-LSD) and HO-LSD glucuronide could be qualitatively detected and PK determined in 11 and 8 subjects, respectively. Nor-LSD was only sporadically detected. Elimination half-lives of iso-LSD (median 12 h) and LSD metabolites (median 9, 7.4, 12, and 11 h for oxo-HO-LSD, HO-LSD, HO-LSD-gluc, and nor-LSD, respectively) exceeded those of LSD (median 4.2 h). However, screening for metabolites to increase detection windows in plasma seems not to be constructive due to their very low concentrations. Copyright © 2016 John Wiley & Sons, Ltd. Copyright © 2016 John Wiley & Sons, Ltd.

  2. Uncertainty estimation in the determination of metals in superficial water by ICP-OES

    NASA Astrophysics Data System (ADS)

    Faustino, Mainara G.; Marques, Joyce R.; Monteiro, Lucilena R.; Stellato, Thamiris B.; Soares, Sabrina M. V.; Silva, Tatiane B. S. C.; da Silva, Douglas B.; Pires, Maria Aparecida F.; Cotrim, Marycel E. B.

    2016-07-01

    From validation studies, it was possible to estimate a measurement uncertainty of several elements such as Al, Ba, Ca, Cu, Cr, Cd, Fe, Mg, Mn, Ni and K in water samples from Guarapiranga Dam. These elements were analyzed by optical emission spectrometry with inductively coupled plasma (ICP-OES). The value of relative estimated uncertainties were between 3% and 15%. The greatest uncertainty contributions were analytical curve, and the recovery method, which were related with elements concentrations and the equipment response. Water samples analyzed were compared with CONAMA Resolution #357/2005.

  3. Determination of calcium, copper, iron, magnesium, manganese, potassium, phosphorus, sodium, and zinc in fortified food products by microwave digestion and inductively coupled plasma-optical emission spectrometry: single-laboratory validation and ring trial.

    PubMed

    Poitevin, Eric

    2012-01-01

    A single-laboratory validation (SLV) and a ring trial (RT) were undertaken to determine nine nutritional elements in food products by inductively coupled plasma-optical emission spectrometry in order to modernize AOAC Official Method 984.27. The improvements involved extension of the scope to all food matrixes (including infant formula), optimized microwave digestion, selected analytical lines, internal standardization, and ion buffering. Simultaneous determination of nine elements (calcium, copper, iron, potassium, magnesium, manganese, sodium, phosphorus, and zinc) was made in food products. Sample digestion was performed through wet digestion of food samples by microwave technology with either closed- or open-vessel systems. Validation was performed to characterize the method for selectivity, sensitivity, linearity, accuracy, precision, recovery, ruggedness, and uncertainty. The robustness and efficiency of this method was proven through a successful RT using experienced independent food industry laboratories. Performance characteristics are reported for 13 certified and in-house reference materials, populating the AOAC triangle food sectors, which fulfilled AOAC criteria and recommendations for accuracy (trueness, recovery, and z-scores) and precision (repeatability and reproducibility RSD, and HorRat values) regarding SLVs and RTs. This multielemental method is cost-efficient, time-saving, accurate, and fit-for-purpose according to ISO 17025 Norm and AOAC acceptability criteria, and is proposed as an extended updated version of AOAC Official Method 984.27 for fortified food products, including infant formula.

  4. Improvement of AOAC Official Method 984.27 for the determination of nine nutritional elements in food products by Inductively coupled plasma-atomic emission spectroscopy after microwave digestion: single-laboratory validation and ring trial.

    PubMed

    Poitevin, Eric; Nicolas, Marine; Graveleau, Laetitia; Richoz, Janique; Andrey, Daniel; Monard, Florence

    2009-01-01

    A single-laboratory validation (SLV) and a ring trial (RT) were undertaken to determine nine nutritional elements in food products by inductively coupled plasma-atomic emission spectroscopy in order to improve and update AOAC Official Method 984.27. The improvements involved optimized microwave digestion, selected analytical lines, internal standardization, and ion buffering. Simultaneous determination of nine elements (calcium, copper, iron, potassium, magnesium, manganese, sodium, phosphorus, and zinc) was made in food products. Sample digestion was performed through wet digestion of food samples by microwave technology with either closed or open vessel systems. Validation was performed to characterize the method for selectivity, sensitivity, linearity, accuracy, precision, recovery, ruggedness, and uncertainty. The robustness and efficiency of this method was proved through a successful internal RT using experienced food industry laboratories. Performance characteristics are reported for 13 certified and in-house reference materials, populating the AOAC triangle food sectors, which fulfilled AOAC criteria and recommendations for accuracy (trueness, recovery, and z-scores) and precision (repeatability and reproducibility RSD and HorRat values) regarding SLV and RT. This multielemental method is cost-efficient, time-saving, accurate, and fit-for-purpose according to ISO 17025 Norm and AOAC acceptability criteria, and is proposed as an improved version of AOAC Official Method 984.27 for fortified food products, including infant formula.

  5. Urinary and plasma oxytocin changes in response to MDMA or intranasal oxytocin administration.

    PubMed

    Francis, Sunday M; Kirkpatrick, Matthew G; de Wit, Harriet; Jacob, Suma

    2016-12-01

    The neuropeptide oxytocin (OT) has received increased experimental attention for its putative role in both normal social functioning and several psychiatric disorders that are partially characterized by social dysfunction (e.g., autism spectrum disorders: ASD). Many human experimental studies measure circulating plasma levels of OT in order to examine the relationship between the hormone and behavior. Urinary OT (uOT) assays offer a simple, easy, and non-invasive method to measure peripheral hormone levels, but the correspondence between uOT and plasma OT (pOT) levels is unclear. Here, we conducted two within-subjects, double-blind studies exploring changes in uOT and pOT levels following administration of two drugs: MDMA, an oxytocin-releasing drug (Study 1), and intranasal oxytocin (INOT: Study 1 and 2). In Study 1, 14 adult participants (2 females) were each administered either oral 1.5mg/kg MDMA or 40IU INOT across two different study sessions. In Study 2, 10 male participants (adolescents and young adults) diagnosed with ASD received either 40IU INOT or placebo across two different sessions. In both studies, blood and urine samples were collected before and after drug administration at each study session. For Study 1, 10 participants provided valid plasma and urine samples for the MDMA session, and 8 provided valid samples for the INOT session. For Study 2, all 10 participants provided valid samples for both INOT and placebo sessions. Pre- and post-administration levels of pOT and uOT were compared. Additionally, correlations between percent change from baseline uOT and pOT levels were examined. Study 1: Plasma OT and uOT levels significantly increased after administration of MDMA and INOT. Furthermore, uOT levels were positively correlated with pOT levels following administration of MDMA (r=0.57, p=0.042) but not INOT (r=0.51, p=0.097). Study 2: There was a significant increase in uOT levels after administration of INOT, but not after administration of placebo. Under both conditions, INOT and placebo, significant increases in pOT levels were not observed. Additionally, change from baseline uOT and pOT levels were positively correlated (r=0.57, p=0.021). There was no significant correlation between uOT and pOT levels following placebo administration. Our results show a measurable and significant increase in pOT and uOT levels after the administration of MDMA (Study 1) and INOT (Study 1 and Study 2). Additionally, a positive correlation between uOT and pOT levels was observed in both samples (healthy adults and ASD patients) in at least one condition. However, uOT and pOT levels were not correlated under all conditions, suggesting that uOT levels do not fully correspond to pOT levels in the time windows we measured. Future studies should further examine the relationship between levels of pOT and uOT in healthy and clinical populations on measures of social behavior because uOT may serve as an additional non-invasive method to measure peripheral OT changes. Copyright © 2016 Elsevier Ltd. All rights reserved.

  6. Size-dependent, sex-dependent and seasonal changes in insulin-lige growth-factor-I in the loggerhead sea turtle

    USGS Publications Warehouse

    Crain, D.A.; Bolten, A.B.; Bjorndal, K.A.; Guillette, L.J.; Gross, T.S.

    1995-01-01

    This study examines size-dependent, sex-dependent, and seasonal fluctuations in plasma insulin-like growth factor-I (IGF-I) concentrations in loggerhead sea turtles (Caretta caretta). Loggerhead turtles (n = 158) were captured in shrimp trawler nets during a 12-month survey in Cape Canaveral Channel, Florida. Plasma samples were analyzed using a validated heterologous radioimmunoassay. Large turtles (>75 cm straight-line carapace length) had significantly higher plasma IGF-I concentrations than small turtles (⩽75 cm; P < 0.0001). Plasma IGF-I concentrations did not vary seasonally in small turtles, but large turtles had significantly higher plasma IGF-I concentrations during the spring and summer months (P < 0.005). Within the large turtles, adult males had significantly lower IGF-I concentrations than females and subadult males (P < 0.05). These results and a review of loggerhead turtle natural history suggest that the seasonal fluctuations in plasma IGF-I of adult turtles are due to elevated IGF-I levels in reproductively active female turtles. Further research is needed to examine correlations between reproductive activities and plasma IGF-I concentrations in reptiles.

  7. Microdose clinical trial: quantitative determination of nicardipine and prediction of metabolites in human plasma.

    PubMed

    Yamane, Naoe; Takami, Tomonori; Tozuka, Zenzaburo; Sugiyama, Yuichi; Yamazaki, Akira; Kumagai, Yuji

    2009-01-01

    A sample treatment procedure and high-sensitive liquid chromatography/tandem mass spectrometry (LC/MS/MS) method for quantitative determination of nicardipine in human plasma were developed for a microdose clinical trial with nicardipine, a non-radioisotope labeled drug. The calibration curve was linear in the range of 1-500 pg/mL using 1 mL of plasma. Analytical method validation for the clinical dose, for which the calibration curve was linear in the range of 0.2-100 ng/mL using 20 microL of plasma, was also conducted. Each method was successfully applied to making determinations in plasma using LC/MS/MS after administration of a microdose (100 microg) and clinical dose (20 mg) to each of six healthy volunteers. We tested new approaches in the search for metabolites in plasma after microdosing. In vitro metabolites of nicardipine were characterized using linear ion trap-fourier transform ion cyclotron resonance mass spectrometry (LIT-FTICRMS) and the nine metabolites predicted to be in plasma were analyzed using LC/MS/MS. There is a strong possibility that analysis of metabolites by LC/MS/MS may advance to utilization in microdose clinical trials with non-radioisotope labeled drugs.

  8. Multivariate classification of edible salts: Simultaneous Laser-Induced Breakdown Spectroscopy and Laser-Ablation Inductively Coupled Plasma Mass Spectrometry Analysis

    NASA Astrophysics Data System (ADS)

    Lee, Yonghoon; Nam, Sang-Ho; Ham, Kyung-Sik; Gonzalez, Jhanis; Oropeza, Dayana; Quarles, Derrick; Yoo, Jonghyun; Russo, Richard E.

    2016-04-01

    Laser-Induced Breakdown Spectroscopy (LIBS) and Laser-Ablation Inductively Coupled Plasma Mass Spectrometry (LA-ICP-MS), both based on laser ablation sampling, can be employed simultaneously to obtain different chemical fingerprints from a sample. We demonstrated that this analysis approach can provide complementary information for improved classification of edible salts. LIBS could detect several of the minor metallic elements along with Na and Cl, while LA-ICP-MS spectra were used to measure non-metallic and trace heavy metal elements. Principal component analysis using LIBS and LA-ICP-MS spectra showed that their major spectral variations classified the sample salts in different ways. Three classification models were developed by using partial least squares-discriminant analysis based on the LIBS, LA-ICP-MS, and their fused data. From the cross-validation performances and confusion matrices of these models, the minor metallic elements (Mg, Ca, and K) detected by LIBS and the non-metallic (I) and trace heavy metal (Ba, W, and Pb) elements detected by LA-ICP-MS provided complementary chemical information to distinguish particular salt samples.

  9. Development of an on-column enrichment technique based on C18-functionalized magnetic silica nanoparticles for the determination of lidocaine in rat plasma by high performance liquid chromatography.

    PubMed

    Chu, Bin; Lou, Dujuan; Yu, Panfeng; Hu, Shaonan; Shen, Shun

    2011-10-14

    In this study, a novel on-column enrichment technique filled with C(18)-functionalized magnetic silica nanoparticles was successfully developed for the determination of lidocaine in rat plasma by high performance liquid chromatography (HPLC). The synthesized Fe(3)O(4)@SiO(2)-C(18) nanoparticles were locally packed into the capillary by the application of magnets. Lidocaine in the sample solutions pumped into the capillary tube could be easily adsorbed by Fe(3)O(4)@SiO(2)-C(18) through hydrophobic interaction by the interior C(18) groups, and eluted by acetonitrile solution. Different extraction conditions were investigated. Method validations including linear range, quantification limit, detection limit, precision, accuracy and recovery were also studied. The results showed that the proposed method based on on-column enrichment by Fe(3)O(4)@SiO(2)-C(18) was a novel, little solvent and efficient approach for the determination of lidocaine in the complex plasma samples. Copyright © 2011 Elsevier B.V. All rights reserved.

  10. Validation of an isotope dilution, ICP-MS method based on internal mass bias correction for the determination of trace concentrations of Hg in sediment cores.

    PubMed

    Ciceri, E; Recchia, S; Dossi, C; Yang, L; Sturgeon, R E

    2008-01-15

    The development and validation of a method for the determination of mercury in sediments using a sector field inductively coupled plasma mass spectrometer (SF-ICP-MS) for detection is described. The utilization of isotope dilution (ID) calibration is shown to solve analytical problems related to matrix composition. Mass bias is corrected using an internal mass bias correction technique, validated against the traditional standard bracketing method. The overall analytical protocol is validated against NRCC PACS-2 marine sediment CRM. The estimated limit of detection is 12ng/g. The proposed procedure was applied to the analysis of a real sediment core sampled to a depth of 160m in Lake Como, where Hg concentrations ranged from 66 to 750ng/g.

  11. LC-MS/MS analysis of metformin, saxagliptin and 5-hydroxy saxagliptin in human plasma and its pharmacokinetic study with a fixed-dose formulation in healthy Indian subjects.

    PubMed

    Shah, Priyanka A; Shah, Jaivik V; Sanyal, Mallika; Shrivastav, Pranav S

    2017-03-01

    A specific and rapid liquid chromatography-tandem mass spectrometry method is proposed for the simultaneous determination of metformin (MET), saxagliptin (SAXA) and its active metabolite, 5-hydroxy saxagliptin (5-OH SAXA) in human plasma. Sample preparation was accomplished from 50 μL plasma sample by solid-phase extraction using sodium dodecyl sulfate as an ion-pair reagent. Reversed-phase chromatographic resolution of analytes was possible within 3.5 min on ACE 5CN (150 × 4.6 mm, 5 μm) column using acetonitrile and10.0 mm ammonium formate buffer, pH 5.0 (80:20, v/v) as the mobile phase. Triple quadrupole mass spectrometric detection was performed using electrospray ionization in the positive ionization mode. The calibration curves showed good linearity (r 2  ≥ 0.9992) over the established concentration range with limit of quantification of 1.50, 0.10 and 0.20 ng/mL for MET, SAXA and 5-OH SAXA respectively. The extraction recoveries obtained from spiked plasma samples were highly consistent for MET (75.12-77.84%), SAXA (85.90-87.84%) and 5-OH SAXA (80.32-82.69%) across quality controls. The validated method was successfully applied to a bioequivalence study with a fixed-dose formulation consisting of 5 mg SAXA and 500 mg MET in 18 healthy subjects. The reproducibility of the assay was demonstrated by reanalysis of 87 incurred samples. Copyright © 2016 John Wiley & Sons, Ltd.

  12. Limited sampling strategy models for estimating the AUC of gliclazide in Chinese healthy volunteers.

    PubMed

    Huang, Ji-Han; Wang, Kun; Huang, Xiao-Hui; He, Ying-Chun; Li, Lu-Jin; Sheng, Yu-Cheng; Yang, Juan; Zheng, Qing-Shan

    2013-06-01

    The aim of this work is to reduce the cost of required sampling for the estimation of the area under the gliclazide plasma concentration versus time curve within 60 h (AUC0-60t ). The limited sampling strategy (LSS) models were established and validated by the multiple regression model within 4 or fewer gliclazide concentration values. Absolute prediction error (APE), root of mean square error (RMSE) and visual prediction check were used as criterion. The results of Jack-Knife validation showed that 10 (25.0 %) of the 40 LSS based on the regression analysis were not within an APE of 15 % using one concentration-time point. 90.2, 91.5 and 92.4 % of the 40 LSS models were capable of prediction using 2, 3 and 4 points, respectively. Limited sampling strategies were developed and validated for estimating AUC0-60t of gliclazide. This study indicates that the implementation of an 80 mg dosage regimen enabled accurate predictions of AUC0-60t by the LSS model. This study shows that 12, 6, 4, 2 h after administration are the key sampling times. The combination of (12, 2 h), (12, 8, 2 h) or (12, 8, 4, 2 h) can be chosen as sampling hours for predicting AUC0-60t in practical application according to requirement.

  13. Simultaneous quantification of major cannabinoids and metabolites in human urine and plasma by HPLC-MS/MS and enzyme-alkaline hydrolysis.

    PubMed

    Aizpurua-Olaizola, Oier; Zarandona, Iratxe; Ortiz, Laura; Navarro, Patricia; Etxebarria, Nestor; Usobiaga, Aresatz

    2017-04-01

    A high performance liquid chromatography coupled to tandem mass spectrometry (HPLC-MS/MS) method for simultaneous quantification of Δ9-tetrahydrocannabinol (THC), its two metabolites 11-hydroxy-Δ9-tetrahydrocannabinol (11-OH-THC) and 11-nor-9-carboxy-Δ9-tetrahydrocannabinol (THC-COOH), and four additional cannabinoids (cannabidiol (CBD), cannabigerol (CBG), tetrahydrocannabivarin (THCV), and cannabinol (CBN)) in 1 mL of human urine and plasma was developed and validated. The hydrolysis process was studied to ensure complete hydrolysis of glucuronide conjugates and the extraction of a total amount of analytes. Initially, urine and plasma blank samples were spiked with THC-COOH-glucuronide and THC-glucuronide, and four different pretreatment methods were compared: hydrolysis-free method, enzymatic hydrolysis with Escherichia Coli β-glucuronidase, alkaline hydrolysis with 10 M NaOH, and enzyme-alkaline tandem hydrolysis. The last approach assured the maximum efficiencies (close to 100%) for both urine and plasma matrices. Regarding the figures of merit, the limits of detection were below 1 ng/mL for all analytes, the accuracy ranged from 84% to 115%, and both within-day and between-day precision were lower than 12%. Finally, the method was successfully applied to real urine and plasma samples from cannabis users. Copyright © 2016 John Wiley & Sons, Ltd. Copyright © 2016 John Wiley & Sons, Ltd.

  14. Evaluation of single-nucleotide polymorphisms as internal controls in prenatal diagnosis of fetal blood groups.

    PubMed

    Doescher, Andrea; Petershofen, Eduard K; Wagner, Franz F; Schunter, Markus; Müller, Thomas H

    2013-02-01

    Determination of fetal blood groups in maternal plasma samples critically depends on adequate amplification of fetal DNA. We evaluated the routine inclusion of 52 single-nucleotide polymorphisms (SNPs) as internal reference in our polymerase chain reaction (PCR) settings to obtain a positive internal control for fetal DNA. DNA from 223 plasma samples of pregnant women was screened for RHD Exons 3, 4, 5, and 7 in a multiplex PCR including 52 SNPs divided into four primer pools. Amplicons were analyzed by single-base extension and the GeneScan method in a genetic analyzer. Results of D screening were compared to standard RHD genotyping of amniotic fluid or real-time PCR of fetal DNA from maternal plasma. The vast majority of all samples (97.8%) demonstrated differences in maternal and fetal SNP patterns when tested with four primer pools. These differences were not observed in less than 2.2% of the samples most probably due to an extraction failure for adequate amounts of fetal DNA. Comparison of the fetal genotypes with independent results did not reveal a single false-negative case among samples (n = 42) with positive internal control and negative fetal RHD typing. Coamplification of 52 SNPs with RHD-specific sequences for fetal blood group determination introduces a valid positive control for the amplification of fetal DNA to avoid false-negative results. This new approach does not require a paternal blood sample. It may also be applicable to other assays for fetal genotyping in maternal blood samples. © 2012 American Association of Blood Banks.

  15. Development and validation of an LC-MS/MS method for the determination of tigecycline in human plasma and cerebrospinal fluid and its application to a pharmacokinetic study.

    PubMed

    Mei, Shenghui; Luo, Xuying; Li, Xingang; Li, Qian; Huo, Jiping; Yang, Li; Zhu, Leting; Feng, Weixing; Zhou, Jianxin; Shi, Guangzhi; Zhao, Zhigang

    2016-12-01

    Tigecycline (TGC) is an important antibiotic in treating various drug-resistant bacteria. The dosage regimen for cerebral intraventricular TGC is still unknown. The aim of the study was to develop and validate liquid chromatography-tandem mass spectrometry (LC-MS/MS) methods for the determination of TGC in human plasma and cerebrospinal fluid (CSF) to obtain an applicable regimen. The ion transitions under ESI positive model were performed at m/z 586.3 > 513.2 and m/z 595.3 > 514.3 for TGC and d9-TGC internal standard (IS). For plasma and CSF samples, the calibration curve of TGC was linear within the ranges 25-2000 and 250-100,000 ng/mL; the IS normalized matrix effect was within the ranges 96.46-101.06% and 101.13-103.58%, respectively, for all. TGC was stable under all tested conditions. The patient received 1 mg intraventricular and 49 mg intravenous administration of TGC. The AUC 0-12 in plasma and CSF calculated according to our noncompartment model were 4713 and 23,0238 h ng/mL, respectively. Given our findings cerebral intraventricular TGC may be a choice for clinicians to treat drug-resistant Gram-negative bacterial-induced meningitis and the safety and efficacy of this administration route warrants further study. Copyright © 2016 John Wiley & Sons, Ltd.

  16. Determination of pseudoprotodioscin in rat plasma by UPLC-MS/MS: Assay development and application to pharmacokinetic study.

    PubMed

    Liao, Min; Chen, Xiao; Chen, Jiefeng; Liu, Mengping; Wang, Junyi; Chen, Zuanguang; Xie, Zhiyong; Yao, Meicun

    2016-07-15

    An original and sensitive ultraperformance liquid chromatography-tandem mass spectrometric (UPLC-MS/MS) method for the determination of pseudoprotodioscin (PPD) in rat plasma was developed and validated. Digitoxin was applied as an internal standard. Plasma samples were processed by acetonitrile-mediated plasma protein precipitation and chromatographed using a step gradient program on a C18 column (2.1×50mm i.d., 1.7μm). The mobile phase was comprised of acetonitrile and 0.1mmolL(-1) aqueous lithium acetate mixed with 0.03% formic acid at the flow rate of 0.2mLmin(-1). Multiple reaction monitoring (MRM) transitions were performed for detection and lithium adduct ions were employed with a significant improvement of the response of the analytes in electrospray positive ionization mode. The concentration range of calibration curve was linear over the range 2-5000ngmL(-1). The intra- and inter-day precisions were all less than 11.5% and accuracies were within the range of 94.1-103.5%, and the analytes exhibited no severe matrix effect. The validated method was successfully applied in the pharmacokinetics of PPD after intragastric (50mgkg(-1)) and intravenous (4mgkg(-1)) administration in rats. PPD showed rapid excretion and with bioavailability of simply about 5.7% in rats. Copyright © 2015 Elsevier B.V. All rights reserved.

  17. Validated high-performance liquid chromatographic method utilizing solid-phase extraction for the simultaneous determination of naringenin and hesperetin in human plasma.

    PubMed

    Kanaze, Feras Imad; Kokkalou, Eugene; Georgarakis, Manolis; Niopas, Ioannis

    2004-03-05

    Naringenin and hesperetin, the aglycones of the flavanone glucosides naringin and hesperidin occur naturally in citrus fruits. They exert a variety of pharmacological effects such as antioxidant, blood lipid-lowering, anticarcinogenic and inhibit selected cytochrome P-450 enzymes resulting in drug interactions. A specific, sensitive, precise, and accurate solid-phase extraction high-performance liquid chromatographic (HPLC) assay for the simultaneous determination of naringenin and hesperetin in human plasma was developed and validated. After addition of 7-ethoxycoumarin as internal standard, plasma samples were incubated with beta-glucuronidase/sulphatase, and the analytes were isolated from plasma by solid-phase extraction using C(18) cartridges and separated on a C(8) reversed phase column with methanol/water/acetic acid (40:58:2, v/v/v) as the eluent at 45 degrees C. The method was linear in the 10-300 ng/ml concentration range for both naringenin and hesperetin (r>0.999). Recovery for naringenin, hesperetin and internal standard was greater than 76.7%. Intra- and inter-day precision for naringenin ranged from 1.4 to 4.2% and from 1.9 to 5.2%, respectively, and for hesperetin ranged from 1.3 to 4.1% and from 1.7 to 5.1%, respectively. Accuracy was better than 91.5 and 91.3% for naringenin and hesperetin, respectively.

  18. Development and evaluation of a hydrophilic interaction liquid chromatography-MS/MS method to quantify 19 nucleobases and nucleosides in rat plasma.

    PubMed

    Du, Yan; Li, Yin-Jie; Hu, Xun-Xiu; Deng, Xu; Qian, Zeng-Ting; Li, Zheng; Guo, Meng-Zhe; Tang, Dao-Quan

    2017-04-01

    As essential endogenous compounds, nucleobases and nucleosides fulfill various functions in living organisms. This study presents the development and validation of a new hydrophilic interaction liquid chromatography tandem mass spectrometry method for simultaneous quantification of 19 nucleobases and nucleosides in rat plasma. For the sample preparation, 15 kinds of protein precipitants were evaluated according to the chromatographic profile and ion response of analytes. The optimization of chromatographic separation was respectively performed using reversed-phase liquid chromatography and hydrophilic interaction liquid chromatography mode; each separation mode included two test columns with different stationary phases. The chromatographic profile and parameters such as half-width (W 1/2 ), capacity factor (K') and tailing factor (f t ) were used to evaluate the separation efficiencies. Furthermore, the adopted composition of two mobile phase systems and the concentrations of the additives in the optimum buffer system were also investigated. The developed method was fully validated and successfully applied quantitatively to determine 19 nucleobases and nucleosides in plasma from normal and diabetic nephropathy (DN) rats. Significant differences between normal and DN rats were found in plasma levels of cytosine, xanthine, thymidine, adenosine, guanosine, inosine and 8-hydroxy-2'-deoxyguanosine. This information may provide a useful reference for the discovery of potential biomarkers of DN. Copyright © 2016 John Wiley & Sons, Ltd.

  19. A validated bioanalytical HPLC method for pharmacokinetic evaluation of 2-deoxyglucose in human plasma

    PubMed Central

    Gounder, Murugesan K.; Lin, Hongxia; Stein, Mark; Goodin, Susan; Bertino, Joseph R.; Kong, Ah-Ng Tony; DiPaola, Robert S.

    2015-01-01

    2-deoxyglucose (2-DG), an analog of glucose, is widely used to interfere with the glycolysis in tumor cells and studied as a therapeutic approach in clinical trials. To evaluate the pharmacokinetics of 2-DG, we describe the development and validation of a sensitive HPLC fluorescent method for the quantitation of 2-DG in plasma. Plasma samples were deproteinized with methanol and the supernatant was dried at 45°C. The residues were dissolved in methanolic sodium acetate/boric acid solution. 2-DG and other monosaccharides were derivatized to 2-aminobenzoic acid derivatives in a single step in the presence of sodium cyanoborohydride at 80°C for 45min. The analytes were separated on a YMC ODS C18 reversed-phase column using gradient elution. The excitation and emission wavelengths were set at 360 and 425nm. The 2-DG calibration curves were linear over the range of 0.63 to 300μg/mL with the limit of detection of 0.5μg/mL. The assay provided satisfactory intra-day and inter-day precision with RSD less than 9.8% and the accuracy ranged from 86.8% to 110.0%. The HPLC method is reproducible and suitable for the quantitation of 2-DG in plasma. The method was successfully applied to characterize the pharmacokinetics profile of 2-DG in patients with advanced solid tumors. PMID:21932382

  20. A highly sensitive LC-MS/MS method for the determination of S-citalopram in rat plasma: application to a pharmacokinetic study in rats.

    PubMed

    Suresh, P S; Giri, Sanjeev; Husain, Raghib; Mullangi, Ramesh

    2010-10-01

    A highly sensitive, rapid assay method has been developed and validated for the estimation of S-citalopram (S-CPM) in rat plasma with liquid chromatography coupled to tandem mass spectrometry with electrospray ionization in the positive-ion mode. The assay procedure involves a simple liquid-liquid extraction of S-CPM and phenacetin (internal standard, IS) from rat plasma with t-butyl methyl ether. Chromatographic separation was operated with 0.2% formic acid:acetonitrile (20:80, v/v) at a flow rate of 0.50 mL/min on a Symmetry Shield RP(18) column with a total run time of 3.0 min. The MS/MS ion transitions monitored were 325.26 → 109.10 for S-CPM and 180.10 → 110.10 for IS. Method validation and pre-clinical sample analysis were performed as per FDA guidelines and the results met the acceptance criteria. The lower limit of quantitation achieved was 0.5 ng/mL and the linearity was observed from 0.5 to 5000 ng/mL. The intra- and inter-day precisions were in the range of 1.14-5.56 and 0.25-12.3%, respectively. This novel method has been applied to a pharmacokinetic study and to estimate brain-to-plasma ratio of S-CPM in rats. Copyright © 2010 John Wiley & Sons, Ltd.

  1. Validation of an immunoassay to measure plasminogen-activator inhibitor-1 concentrations in human saliva

    PubMed Central

    Zhang, Xi; Dimeski, Goce; Punyadeera, Chamindie

    2014-01-01

    Introduction: We have previously shown that the concentrations of D-dimer are significantly elevated in saliva compared with plasma. Saliva offers several advantages compared with blood analysis. We hypothesised that human saliva contains plasminogen activator inhibitor-1 (PAI-1) and that the concentrations are not affected by the time of saliva collection. The aim was to adopt and validate an immunoassay to quantify PAI-1 concentrations in saliva and to determine whether saliva collection time has an influence in the measurement. Materials and methods: Two saliva samples (morning and afternoon) from the same day were collected from healthy subjects (N = 40) who have had no underlying heart conditions. A customized AlphaLISA® immunoassay (PerkinElmer®, MA, USA) was adopted and used to quantify PAI-1 concentrations. We validated the analytical performance of the customized immunoassay by calculating recovery of known amount of analyte spiked in saliva. Results: The recovery (95.03%), intra- (8.59%) and inter-assay (7.52%) variations were within the acceptable ranges. The median salivary PAI-1 concentrations were 394 pg/mL (interquartile ranges (IQR) 243.4–833.1 pg/mL) in the morning and 376 (129.1–615.4) pg/mL in the afternoon and the plasma concentration was 59,000 (24,000–110,000) pg/mL. Salivary PAI-1 did not correlate with plasma (P = 0.812). Conclusions: The adopted immunoassay produced acceptable assay sensitivity and specificity. The data demonstrated that saliva contains PAI-1 and that its concentration is not affected by the time of saliva collection. There is no correlation between salivary and plasma PAI-1 concentrations. Further studies are required to demonstrate the utility of salivary PAI-1 in CVD risk factor studies. PMID:24969919

  2. Determination of a highly selective mixed-affinity sigma receptor ligand, in rat plasma by ultra performance liquid chromatography mass spectrometry and its application to a pharmacokinetic study

    PubMed Central

    Jamalapuram, Seshulatha; Vuppala, Pradeep K.; Mesangeau, Christophe; McCurdy, Christopher R.; Avery, Bonnie A.

    2014-01-01

    A selective, rapid and sensitive ultra performance liquid chromatography mass spectrometry (UPLC/MS) method was developed and validated to quantitate a highly selective mixed-affinity sigma receptor ligand, CM156 (3-(4-(4-cyclohexylpiperazin-1-yl)butyl)benzo[d] thiazole-2(3H)-thione), in rat plasma. CM156 and the internal standard (aripiprazole) were extracted from plasma samples by a single step liquid–liquid extraction using chloroform. The analysis was carried out on an ACQUITY UPLCTM BEH HILIC column (1.7 µm, 2.1 mm × 50 mm) with isocratic elution at flow rate of 0.2 mL/min using 10 mM ammonium formate in 0.1% formic acid and acetonitrile (10:90) as the mobile phase. The detection of the analyte was performed on a mass spectrometer operated in selected ion recording (SIR) mode with positive electrospray ionization (ESI). The validated analytical method resulted in a run time of 4 min and the retention times observed were 2.6 ± 0.1 and 2.1 ± 0.1 min for CM156 and the IS, respectively. The calibration curve exhibited excellent linearity over a concentration range of 5–4000 ng/mL with the lower limit of quantification of 5 ng/mL. The intra- and inter-day precision values were below 15% and accuracy ranged from −6.5% to 5.0%. The mean recovery of CM156 from plasma was 96.8%. The validated method was applied to a pilot intravenous pharmacokinetic study in rats. PMID:22406103

  3. Validation of a chiral LC-MS/MS-ESI method for the simultaneous quantification of darolutamide diastereomers in mouse plasma and its application to a stereoselective pharmacokinetic study in mice.

    PubMed

    Balaji, Narayanan; Sulochana, Suresh P; Saini, Neeraj Kumar; A, Siva Kumar; Mullangi, Ramesh

    2018-05-01

    A simple, selective and reliable LC-MS/MS method was validated for simultaneous quantitation of darolutamide diastereomers in 50 μL mouse plasma using warfarin as an internal standard (IS) as per regulatory guidelines. Plasma samples were extracted by liquid-liquid extraction and the chromatographic separation was achieved on a Chiralpak IA column with an isocratic mobile phase 5 mm ammonium acetate-absolute alcohol (20:80, v/v) at a flow rate of 1.0 mL/min. Detection and quantitation was done in multiple reaction monitoring mode following the transitions m/z 397 → 202 and 307 → 250 for darolutamide diastereomers and the IS, respectively, in the negative ionization mode. The linearity range was 100-2400 ng/mL for each diastereomer. The intra- and inter-day precisions were in the ranges of 1.78-4.20 and 4.34-14.6, and 3.63-4.74 and 4.78-5.15 for diastereomer-1 and diastereomer-2, respectively. Both diastereomers were found to be stable under different stability conditions. The validated method was applied to a pharmacokinetic study in mice. Following oral administration of darolutamide at 10 mg/kg, maximum concentration in plasma was 4189 and 726 ng/mL for diastereomer-1 and diastereomer-2, respectively. The terminal half-life was found to be ~0.50 h for both the diastereomers. The AUC (0-t) was found to be 18,961 ng*h/mL for diastereomer-1 and 1340 ng*h/mL diastereomer-2. Copyright © 2018 John Wiley & Sons, Ltd.

  4. Development, validation and application of the liquid chromatography tandem mass spectrometry method for simultaneous quantification of azilsartan medoxomil (TAK-491), azilsartan (TAK-536), and its 2 metabolites in human plasma.

    PubMed

    Kuze, Yoji; Kogame, Akifumi; Jinno, Fumihiro; Kondo, Takahiro; Asahi, Satoru

    2015-09-15

    Azilsartan medoxomil potassium salt (TAK-491) is an orally administered angiotensin II type 1 receptor blocker for the treatment of hypertension and is an ester-based prodrug that is rapidly hydrolyzed to the pharmacologically active moiety, azilsartan (TAK-536), during absorption. TAK-536 is biotransformed to the 2 metabolites M-I by decarboxylation and M-II by dealkylation. In this study, we developed and validated a LC/MS/MS method which can simultaneously determine 4 analytes, TAK-491, TAK-536, M-I and M-II. The bioanalytical method can be outlined as follows: two structural analogues are used as the internal standards. The analytes and the IS are extracted from human plasma using solid phase extraction. After evaporating, the residue is reconstituted and injected into a LC/MS/MS system with an ESI probe and analyzed in the positive ion mode. Separation is performed through a conventional reversed-phase column with a mobile phase of water/acetonitrile/acetic acid (40:60:0.05, v/v/v) mixture at a flow rate of 0.2mL/min. The total run time is 8.5min. The calibration range is 1-2500ng/mL in human plasma for all the analytes. Instability issues of the prodrug, TAK-491, were overcome and all the validation results met the acceptance criteria in accordance with the regulatory guideline/guidance. As a result of the clinical study, the human PK profiles of TAK-536, M-I and M-II were successfully obtained and also it was confirmed that TAK-491 was below the LLOQ (1ng/mL) in the human plasma samples. Copyright © 2015 Elsevier B.V. All rights reserved.

  5. LC-MS/MS method for the determination of clodronate in human plasma.

    PubMed

    Hasan, Mahmoud; Schumacher, Gitta; Seekamp, Anne; Taedken, Tobias; Siegmund, Werner; Oswald, Stefan

    2014-11-01

    Clodronate belongs to the class of bisphosphonates which are used for the treatment of bone disorders. Due to its high polarity it has a low and highly variable oral bioavailability which results in low plasma concentrations and requires sensitive bioanalytical methods to characterize its pharmacokinetics in human. Here, we describe for the first time the development and validation of a LC-MS/MS assay for the quantification of clodronate in human plasma. The bisphosphonate was isolated from the biological matrix by protein precipitation using perchloric acid (10%), and derivatized with trimethylorthoacetate prior sample clean-up with liquid-liquid extraction using methyl tert-butyl ether. The chromatography was performed using an isocratic elution with ammonium acetate 5mM (85% v/v, pH 3.8) and acetonitrile (15% v/v) as mobile phase with a flow rate of 300μl/min on a reversed-phase column (Supelco Ascentis(®), C18) temporized at 50°C. The mass spectrometric detection was done using the API4000 triple quadruple mass spectrometer monitoring the mass/charge transitions 301.0/145 for clodronate and 305.2/137.1 for the internal standard etidronate. The analytical range was set to 5-800ng/ml, allowing an evaluation of the plasma concentration-time profiles of clodronate for approximately 7-8 half-life (∼24h). The method was validated according to current FDA/EMA guidelines on bioanalytical method validation with respect to specificity, linearity, intra- and inter-day accuracy and precision, matrix effect, recovery as well as stability. The precision of the assay was 0.6-6.9% and 0.6-8.1% for the intra-day and inter-day variability, respectively. The intra-day and inter-day accuracy (error) was 0.6-8.8% and 2.2-4.5%. The recovery of the analyte was low (2-3%) but reproducible over the entire validation range and sufficient to monitor the target concentrations in human plasma. The drug was shown to be stable in plasma at room temperature for at least 3h (96.0±6%) and for at least 24h when stored in the cooled autosampler at 4°C (102.4±4.5%). Clodronate can also undergo up to three freeze-thaw cycles without impaired stability. Thus, the method was shown to possess sufficient specificity, sensitivity, accuracy, precision and stability to measure plasma concentrations of clodronate. Finally, the developed method was successfully applied to study the clodronate serum levels in a pharmacokinetic study in healthy volunteers. Copyright © 2014 Elsevier B.V. All rights reserved.

  6. Comparison of pharmacokinetic profiles of moxifloxacin in Caesarean versus non-pregnant sectioned women by fully validated HPLC with fluorescence detection.

    PubMed

    Nemutlu, Emirhan; Kir, Sedef; Eroglu, Hakan; Katlan, Doruk; Ozek, Aykut; Özyüncü, Özgür; Oyüncü, Ozgür; Beksaç, M Sinan

    2010-07-01

    In this study, a simple, rapid, cost-effective, and sensitive reversed-phase high-performance liquid chromatographic method has been developed and validated for the analysis of moxifloxacin in plasma. The chromatographic separation was achieved on a Zorbax Eclipse XDB-C18 column (150 mm x 4.6 mm i.d.) connected to a Phenomenex C(18) column (4 mm x 3.0 mm i.d.) using a mixture of acetonitrile: 15 mM citrate buffer (pH 3) (23:77, v/v) as the mobile phase with isocratic system at a flow rate of 1 mL/min. Fluorescence detection was employed with excitation at 290 nm and emission at 500 nm. Lomefloxacin was used as internal standard. Plasma samples were prepared with addition of acetonitrile only. The method was fully validated according to the International Conference on Harmonization (ICH) guidelines. The results of the validation parameters were: linearity range, 3-6000 ng/mL (R(2) = 0.9994); mean recovery, 100.48 %; limit of quantification, 5 ng/mL; limit of detection, 1 ng/mL; and intra- and inter-day precision less than 3.2% and 5.1%, respectively. The robustness of the method was evaluated and confirmed with fractional factorial design. After validation studies, the method was applied in order to conclude the effects of pregnancy on postoperative pharmacokinetic profiles of moxifloxacin. For this aim, moxifloxacin was given to non-pregnant women (n=9) and caesarean-sectioned women (n=6) as a single intravenous dose (400 mg Avelox(R) infusion). Plasma samples were analyzed in order to compare pharmacokinetic profiles of pregnants and non-pregnants. Peak serum concentrations of non-pregnant and caesarean-sectioned women at the arterial port after the infusion were 4.95 +/- 1.50 and 1.56 +/- 0.16 microg/mL, respectively. The mean elimination half-life, volume of distribution and calculated area under the concentration-time curve (AUC)(0-infinity) were 5.54 +/- 0.73 h, 65.58 +/- 6.30 L and 49.95 +/- 6.30 microg.h/mL for non-pregnant women and 3.50 +/- 0.37 h, 215.85 +/- 24.87 L and 10.53 +/- 0.66 microg.h/mL for caesarean-sectioned women, respectively. These results indicated that pregnancy has a significant effect on the pharmacokinetics of moxifloxacin.

  7. Noninvasive Measurement of Steroid Hormones in Zebrafish Holding-Water

    PubMed Central

    Félix, Ana S.; Faustino, Ana I.; Cabral, Eduarda M.

    2013-01-01

    Abstract Zebrafish (Danio rerio) has recently emerged as a new animal model in neuroendocrinology and behavior (e.g., stress physiology and ecotoxicology studies). In these areas, the concentrations of steroid hormones in the blood are often used to study the endocrinological status of individuals. However, due to the small body size of zebrafish, blood sampling is difficult to perform and the amount of plasma obtained per sample for assaying hormones is very small (ca. 1–5 μL), and therefore most studies have been using whole-body hormone concentrations, which implies sacrificing the individuals and hampers sequential sampling of the same individual. Here a noninvasive method to assay steroid hormones from zebrafish holding-water, based on the fact that steroids are released into the fish holding-water through the gills by passive diffusion, is validated. Cortisol and the androgen 11-ketotestosterone (KT) were measured in water samples and compared to plasma levels in the same individuals. Cortisol released to holding-water correlates positively with plasma concentrations, but there was a lack of correlation between KT water and circulating levels. However, KT levels showed a highly significant sex difference that can be used to noninvasively sex individuals. An ACTH challenge test demonstrated that an induced increase in circulating cortisol concentration can be reliably detected in holding-water levels, hence attesting the responsiveness of holding-water levels to fluctuations in circulating levels. PMID:23445429

  8. Propagation of an ultrashort, intense laser pulse in a relativistic plasma

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Ritchie, B.; Decker, C.D.

    1997-12-31

    A Maxwell-relativistic fluid model is developed for the propagation of an ultrashort, intense laser pulse through an underdense plasma. The separability of plasma and optical frequencies ({omega}{sub p} and {omega} respectively) for small {omega}{sub p}/{omega} is not assumed; thus the validity of multiple-scales theory (MST) can be tested. The theory is valid when {omega}{sub p}/{omega} is of order unity or for cases in which {omega}{sub p}/{omega} {much_lt} 1 but strongly relativistic motion causes higher-order plasma harmonics to be generated which overlap the region of the first-order laser harmonic, such that MST would not expected to be valid although its principalmore » validity criterion {omega}{sub p}/{omega} {much_lt} 1 holds.« less

  9. Determination of psilocin, bufotenine, LSD and its metabolites in serum, plasma and urine by SPE-LC-MS/MS.

    PubMed

    Martin, Rafaela; Schürenkamp, Jennifer; Gasse, Angela; Pfeiffer, Heidi; Köhler, Helga

    2013-05-01

    A validated method for the simultaneous determination of psilocin, bufotenine, lysergic acid diethylamide and its metabolites in serum, plasma and urine using liquid chromatography-electrospray ionization/tandem mass spectrometry was developed. During the solid-phase extraction procedure with polymeric mixed-mode cation exchange columns, the unstable analytes were protected by ascorbic acid, drying with nitrogen and exclusion of light. The limits of detection and quantitation for all analytes were low. Recovery was ≥86 % for all analytes and no significant matrix effects were observed. Interday and intraday imprecisions at different concentrations ranged from 1.1 to 8.2 % relative standard deviation, bias was within ±5.3 %. Processed samples were stable in the autosampler for at least 2 days. Furthermore, freeze/thaw and long-term stability were investigated. The method was successfully applied to authentic serum and urine samples.

  10. Simultaneous analysis of hydrochlorothiazide, triamterene and reserpine in rat plasma by high performance liquid chromatography and tandem solid-phase extraction.

    PubMed

    Li, Hang; He, Junting; Liu, Qin; Huo, Zhaohui; Liang, Si; Liang, Yong

    2011-03-01

    A tandem solid-phase extraction method (SPE) of connecting two different cartridges (C(18) and MCX) in series was developed as the extraction procedure in this article, which provided better extraction yields (>86%) for all analytes and more appropriate sample purification from endogenous interference materials compared with a single cartridge. Analyte separation was achieved on a C(18) reversed-phase column at the wavelength of 265 nm by high-performance liquid chromatography (HPLC). The method was validated in terms of extraction yield, precision and accuracy. These assays gave mean accuracy values higher than 89% with RSD values that were always less than 3.8%. The method has been successfully applied to plasma samples from rats after oral administration of target compounds. Copyright © 2011 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  11. Characterization of the Phase Composition of Nanosized Lithium Titanates Synthesized by Inductive Thermal Plasma

    NASA Astrophysics Data System (ADS)

    Quesnel, François; Soucy, Gervais; Veilleux, Jocelyn; Hovington, Pierre; Zhu, Wen; Zaghib, Karim

    The properties of lithium titanates anodes in Li-ion batteries are highly dependent on their secondary constituents. While their main phase is usually constituted of Li4Ti5O12, significant quantity of lithium titanates compounds of various stoichiometry are often present, due to either the processing, usage or aging of the material. These may go underreported, as many of these spectrums overlap or display low signal in X-ray diffraction (XRD). Samples of nanosized lithium titanates synthetized by inductive plasma were characterized by XRD and scanning electron microscopy (SEM), as they provide a regular yet typical crystallite size and shape including multiple phases. A Rietveld refinement was developed to extract the composition of these samples. Mass balance through further annealing and differential scanning calorimetry (DSC) enthalpy measurements from phase transformations were also used as identification and validation techniques.

  12. A microfluidic biochip platform for electrical quantification of proteins.

    PubMed

    Valera, Enrique; Berger, Jacob; Hassan, Umer; Ghonge, Tanmay; Liu, Julia; Rappleye, Michael; Winter, Jackson; Abboud, Daniel; Haidry, Zeeshan; Healey, Ryan; Hung, Na-Teng; Leung, Nathaniel; Mansury, Naif; Hasnain, Alexander; Lannon, Christine; Price, Zachary; White, Karen; Bashir, Rashid

    2018-05-15

    Sepsis, an adverse auto-immune response to an infection often causing life-threatening complications, results in the highest mortality and treatment cost of any illness in US hospitals. Several immune biomarker levels, including Interleukin 6 (IL-6), have shown a high correlation to the onset and progression of sepsis. Currently, no technology diagnoses and stratifies sepsis progression using biomarker levels. This paper reports a microfluidic biochip platform to detect proteins in undiluted human plasma samples. The device uses a differential enumeration platform that integrates Coulter counting principles, antigen specific capture chambers, and micro size bead based immunodetection to quantify cytokines. This microfluidic biochip was validated as a potential point of care technology by quantifying IL-6 from plasma samples (n = 29) with good correlation (R2 = 0.81) and agreement (Bland-Altman) compared to controls. In combination with previous applications, this point of care platform can potentially detect cell and protein biomarkers simultaneously for sepsis stratification.

  13. Development and validation of an HPLC-MS/MS method to determine clopidogrel in human plasma. Use of incurred samples to test back-conversion.

    PubMed

    Silvestro, Luigi; Gheorghe, Mihaela Cristina; Tarcomnicu, Isabela; Savu, Silviu; Savu, Simona Rizea; Iordachescu, Adriana; Dulea, Constanta

    2010-11-15

    Quantitative methods using LC-MS/MS allow achievement of adequate sensitivity for pharmacokinetic studies with clopidogrel; three such methods, with LLOQs as low as 5 pg/mL, were developed and fully validated according to the well established FDA 2001 guidelines. The chromatographic separations were performed on reversed phase columns Ascentis RP-Amide (15 cm x 2.1 mm, 5 μm), Ascentis Express C8 (10 cm x 2.1 mm, 2.7 μm) and Ascentis Express RP Amide (10 cm x 2.1 mm, 2.7 μm), respectively. Positive electrospray ionization in MRM mode was employed for the detection and a deuterated analogue (d3-clopidogrel) was used as internal standard. Linearity, precision, extraction recovery, matrix effects and stability tests on blank plasma spiked with clopidogrel and stored in different conditions met the acceptance criteria. During the analysis of the real samples from the first pharmacokinetic study, a significant increase (>100%) of the measured clopidogrel concentrations in the extracts kept in the autosampler at 10 °C was observed. Investigations led to the conclusion that most probably a back-conversion of one or more of the clopidogrel metabolites is occurring. The next methods were optimized in order to minimize this back-conversion. After a series of experiments, the adjustment of the sample preparation (e.g. processing at low temperature and introducing a clean-up step on Supelco HybridSPE-Precipitation cartridges) has proven to be the most effective in order to improve the stability of the extracts. Incurred samples of real subjects were successfully used in the validation of the last two analytical methods to evaluate the back-conversion, while tests using only the known metabolites could not detect this important problem. Copyright © 2010 Elsevier B.V. All rights reserved.

  14. Validated HPLC-UV method for determination of naproxen in human plasma with proven selectivity against ibuprofen and paracetamol.

    PubMed

    Filist, Monika; Szlaska, Iwona; Kaza, Michał; Pawiński, Tomasz

    2016-06-01

    Estimating the influence of interfering compounds present in the biological matrix on the determination of an analyte is one of the most important tasks during bioanalytical method development and validation. Interferences from endogenous components and, if necessary, from major metabolites as well as possible co-administered medications should be evaluated during a selectivity test. This paper describes a simple, rapid and cost-effective HPLC-UV method for the determination of naproxen in human plasma in the presence of two other analgesics, ibuprofen and paracetamol. Sample preparation is based on a simple liquid-liquid extraction procedure with a short, 5 s mixing time. Fenoprofen, which is characterized by a similar structure and properties to naproxen, was first used as the internal standard. The calibration curve is linear in the concentration range of 0.5-80.0 µg/mL, which is suitable for pharmacokinetic studies following a single 220 mg oral dose of naproxen sodium. The method was fully validated according to international guidelines and was successfully applied in a bioequivalence study in humans. Copyright © 2015 John Wiley & Sons, Ltd. Copyright © 2015 John Wiley & Sons, Ltd.

  15. Novel rapid liquid chromatography tandem masspectrometry method for vemurafenib and metabolites in human plasma, including metabolite concentrations at steady state.

    PubMed

    Vikingsson, Svante; Strömqvist, Malin; Svedberg, Anna; Hansson, Johan; Höiom, Veronica; Gréen, Henrik

    2016-08-01

    A novel, rapid and sensitive liquid chromatography tandem-mass spectrometry method for quantification of vemurafenib in human plasma, that also for the first time allows for metabolite semi-quantification, was developed and validated to support clinical trials and therapeutic drug monitoring. Vemurafenib was analysed by precipitation with methanol followed by a 1.9 min isocratic liquid chromatography tandem masspectrometry analysis using an Acquity BEH C18 column with methanol and formic acid using isotope labelled internal standards. Analytes were detected in multireaction monitoring mode on a Xevo TQ. Semi-quantification of vemurafenib metabolites was performed using the same analytical system and sample preparation with gradient elution. The vemurafenib method was successfully validated in the range 0.5-100 μg/mL according to international guidelines. The metabolite method was partially validated owing to the lack of commercially available reference materials. For the first time concentration levels at steady state for melanoma patients treated with vemurafenib is presented. The low abundance of vemurafenib metabolites suggests that they lack clinical significance. Copyright © 2016 John Wiley & Sons, Ltd. Copyright © 2016 John Wiley & Sons, Ltd.

  16. Pharmacokinetic Modeling of Intranasal Scopolamine in Plasma Saliva and Urine

    NASA Technical Reports Server (NTRS)

    Wu, L.; Chow, D. S. L.; Tam, V.; Putcha, L.

    2014-01-01

    An intranasal gel formulation of scopolamine (INSCOP) was developed for the treatment of Space Motion Sickness. The bioavailability and pharmacokinetics (PK) were evaluated under the Food and Drug Administration guidelines for clinical trials for an Investigative New Drug (IND). The aim of this project was to develop a PK model that can predict the relationship between plasma, saliva and urinary scopolamine concentrations using data collected from the IND clinical trial with INSCOP. METHODS: Twelve healthy human subjects were administered three dose levels (0.1, 0.2 and 0.4 mg) of INSCOP. Serial blood, saliva and urine samples were collected between 5 min to 24 h after dosing and scopolamine concentrations measured by using a validated LC-MS-MS assay. Pharmacokinetic Compartmental models, using actual dosing and sampling times, were built using Phoenix (version 1.2). Model discrimination was performed, by minimizing the Akaike Information Criteria (AIC), maximizing the coefficient of determination (r²) and by comparison of the quality of fit plots. RESULTS: The best structural model to describe scopolamine disposition after INSCOP administration (minimal AIC =907.2) consisted of one compartment for plasma, saliva and urine respectively that were inter-connected with different rate constants. The estimated values of PK parameters were compiled in Table 1. The model fitting exercises revealed a nonlinear PK for scopolamine between plasma and saliva compartments for K21, Vmax and Km. CONCLUSION: PK model for INSCOP was developed and for the first time it satisfactorily predicted the PK of scopolamine in plasma, saliva and urine after INSCOP administration. Using non-linear PK yielded the best structural model to describe scopolamine disposition between plasma and saliva compartments, and inclusion of non-linear PK resulted in a significant improved model fitting. The model can be utilized to predict scopolamine plasma concentration using saliva and/or urine data that allows non-invasive assessment of pharmacotherapeutics of scopolamine in space and other remote environments without requiring blood sampling.

  17. Transfer of perfluoroalkyl substances from mother to fetus in a Spanish birth cohort.

    PubMed

    Manzano-Salgado, Cyntia B; Casas, Maribel; Lopez-Espinosa, Maria-Jose; Ballester, Ferran; Basterrechea, Mikel; Grimalt, Joan O; Jiménez, Ana-María; Kraus, Thomas; Schettgen, Thomas; Sunyer, Jordi; Vrijheid, Martine

    2015-10-01

    Prenatal exposure to perfluoroalkyl substances (PFAS) might affect child health; thus estimating PFAS fetal burden is relevant. PFAS fetal burden is best estimated in cord samples; previous studies have used either maternal plasma or serum during pregnancy as proxy, but their validity is not clear. We aimed to evaluate PFAS transfer between mother and fetus and determine its predictors in a Spanish birth cohort. We measured perfluorobutane sulfonate (PFBS), perfluorohexane sulfonate (PFHxS), perfluorooctane sulfonate (PFOS), perfluorooctanoate (PFOA), and perfluorononanoate (PFNA) in maternal blood and cord serum from 66 mother-child pairs. We used Spearman's rank coefficients to correlate PFAS concentrations in first trimester maternal plasma and serum, with cord serum samples. We assessed PFAS placental transfer by calculating maternal to cord ratios and examined their association with maternal socio-demographic characteristics and child sex using linear regression models. Median concentrations of PFAS (ng/mL) of PFHxS, PFOS, PFOA, and PFNA in maternal plasma (0.79, 6.18, 2.85 and 0.84, respectively) and serum (0.84, 6.99, 2.97 and 0.85) were higher than in cord serum (0.40, 1.86, 1.90 and 0.32). PFBS was not detected. Positive Spearman's correlations (p-values<0.001) were found between maternal plasma and serum (⍴≥0.80), maternal plasma and cord (⍴≥0.66), and maternal serum and cord samples (⍴≥0.67). Maternal plasma to cord ratios were above 1 (PFHxS: 2.35 [95%CI: 2.05, 2.70], PFOS: 3.33 [3.05, 3.62], PFOA: 1.37 [1.27, 1.48], PFNA: 2.39 [2.18, 2.63]); maternal serum to cord ratios were similar. Maternal to cord ratios decreased with maternal age, but not with other socio-demographic factors. Our results suggest that PFAS fetal body burden can be assessed using as proxy maternal plasma or serum collected early in pregnancy. Maternal age might influence PFAS placental transfer. Copyright © 2015 Elsevier Inc. All rights reserved.

  18. Measurement of neosaxitoxin in human plasma using liquid-chromatography tandem mass spectrometry: Proof of concept for a pharmacokinetic application.

    PubMed

    Peake, Roy W A; Zhang, Victoria Y; Azcue, Nina; Hartigan, Christina E; Shkreta, Aida; Prabhakara, Jasmina; Berde, Charles B; Kellogg, Mark D

    2016-11-15

    Neosaxitoxin, a member of the saxitoxin family of paralytic shellfish poisoning toxins, has shown potential as an effective, long-acting, anesthetic. We describe the development and validation of a highly sensitive method for measurement of neosaxitoxin in human plasma using liquid chromatography tandem mass spectrometry (LC-MS/MS) and provide evidence for its use in a human pharmacokinetic study. Samples were prepared using cation exchange solid phase extraction followed by hydrophilic interaction liquid chromatography and MS/MS detection in positive electrospray ionization mode. Multiple reaction monitoring was used to monitor neosaxitoxin (m/z 316.17>220.07) and the internal standard analogue decarbamoylneosaxitoxin (m/z 273.12>180.00). The method was validated for lower limit of quantification, precision, accuracy, linearity and matrix effect. The stability of neosaxitoxin in plasma matrix at various storage conditions was also investigated. Standard curves for calibration were linear (r>0.995) across the assay calibration range, 10 to 1000pg/mL. The analytical measurable range of the assay was 10-10,000pg/mL in plasma matrix. This method has demonstrated excellent sensitivity demonstrating a lower limit of quantification in human plasma of 10pg/mL. The mean, inter-batch variation was <5.2% across the concentration range 30 to 800pg/mL. This method was successfully used in a phase 1 trial to investigate the pharmacokinetic profile of neosaxitoxin in humans following the intravenous administration of the drug at a range of doses up to 40μg. We conclude that our high-sensitivity method for measurement of neosaxitoxin in human plasma is capable of supporting future clinical trials. Copyright © 2016 Elsevier B.V. All rights reserved.

  19. Validation of an enzyme-linked immunosorbent assay for the quantification of citrullinated histone H3 as a marker for neutrophil extracellular traps in human plasma.

    PubMed

    Thålin, Charlotte; Daleskog, Maud; Göransson, Sophie Paues; Schatzberg, Daphne; Lasselin, Julie; Laska, Ann-Charlotte; Kallner, Anders; Helleday, Thomas; Wallén, Håkan; Demers, Mélanie

    2017-06-01

    There is an emerging interest in the diverse functions of neutrophil extracellular traps (NETs) in a variety of disease settings. However, data on circulating NETs rely largely upon surrogate NET markers such as cell-free DNA, nucleosomes, and NET-associated enzymes. Citrullination of histone H3 by peptidyl arginine deiminase 4 (PAD4) is central for NET formation, and citrullinated histone H3 (H3Cit) is considered a NET-specific biomarker. We therefore aimed to optimize and validate a new enzyme-linked immunosorbent assay (ELISA) to quantify the levels of H3Cit in human plasma. A standard curve made of in vitro PAD4-citrullinated histones H3 allows for the quantification of H3Cit in plasma using an anti-histone antibody as capture antibody and an anti-histone H3 citrulline antibody for detection. The assay was evaluated for linearity, stability, specificity, and precision on plasma samples obtained from a human model of inflammation before and after lipopolysaccharide injection. The results revealed linearity and high specificity demonstrated by the inability of detecting non-citrullinated histone H3. Coefficients of variation for intra- and inter-assay variability ranged from 2.1 to 5.1% and from 5.8 to 13.5%, respectively, allowing for a high precision. Furthermore, our results support an inflammatory induction of a systemic NET burden by showing, for the first time, clear intra-individual elevations of plasma H3Cit in a human model of lipopolysaccharide-induced inflammation. Taken together, our work demonstrates the development of a new method for the quantification of H3Cit by ELISA that can reliably be used for the detection of NETs in human plasma.

  20. Simultaneous quantification and semi-quantification of ginkgolic acids and their metabolites in rat plasma by UHPLC-LTQ-Orbitrap-MS and its application to pharmacokinetics study.

    PubMed

    Qian, Yiyun; Zhu, Zhenhua; Duan, Jin-Ao; Guo, Sheng; Shang, Erxin; Tao, Jinhua; Su, Shulan; Guo, Jianming

    2017-01-15

    A highly sensitive method using ultra-high-pressure liquid chromatography coupled with linear ion trap-Orbitrap tandem mass spectrometry (UHPLC-LTQ-Orbitrap-MS) has been developed and validated for the simultaneous identification and quantification of ginkgolic acids and semi-quantification of their metabolites in rat plasma. For the five selected ginkgolic acids, the method was found to be with good linearities (r>0.9991), good intra- and inter-day precisions (RSD<15%), and good accuracies (RE, from -10.33% to 4.92%) as well. Extraction recoveries, matrix effects and stabilities for rat plasm samples were within the required limits. The validated method was successfully applied to investigate the pharmacokinetics of the five ginkgolic acids in rat plasma after oral administration of 3 dosage groups (900mg/kg, 300mg/kg and 100mg/kg). Meanwhile, six metabolites of GA (15:1) and GA (17:1) were identified by comparison of MS data with reported values. The results of validation in terms of linear ranges, precisions and stabilities were established for semi-quantification of metabolites. The curves of relative changes of these metabolites during the metabolic process were constructed by plotting the peak area ratios of metabolites to salicylic acid (internal standard, IS), respectively. Double peaks were observed in all 3 dose groups. Different type of metabolites and different dosage of each metabolite both resulted in different T max . Copyright © 2016 Elsevier B.V. All rights reserved.

  1. Simultaneous determination of tetrahydropalmatine, protopine, and palmatine in rat plasma by LC-ESI-MS and its application to a pharmacokinetic study.

    PubMed

    Ma, Hongda; Wang, Yongjun; Guo, Tao; He, Zhonggui; Chang, Xinyu; Pu, Xiaohui

    2009-02-20

    A sensitive and specific liquid chromatography-electrospray ionization-mass spectrometry (LC-ESI-MS) method has been developed and validated for the simultaneous quantification of tetrahydropalmatine, protopine and palmatine in rat plasma using phenacetin as the internal standard (IS). Two hundred microliters plasma samples were extracted by dichloromethane under a strong basic condition. The analytes were separated by a C18 column and detected with a single quadrupole mass spectrometer. The used mobile phase was acetonitrile-water (40:60, v/v) containing 5mM ammonium acetate and 0.2% glacial acetic acid. Detection was carried out by positive electrospray ionization in selected ion reaction (SIR) mode at m/z 356.6 for tetrahydropalmatine, 354.6 for protopine, 352.6 for palmatine and 180.4 for the IS, respectively. The method was validated over the concentration range of 1.00-500ngmL(-1) and the lower limit of quantification (LLOQ) was 1.00ngmL(-1) for all three analytes. The intra- and inter-day precision values were less than 9% relative standard deviation (R.S.D.), and the relative error ranged from -7.4 to 4.8%. The extraction recoveries were on average 91.42% for tetrahydropalmatine, 84.75% for protopine, 57.26% for palmatine, and 83.18% for IS. The validated method was successfully applied to a pharmacokinetic study of tetrahydropalmatine, protopine and palmatine in rats after oral administration of Rhizoma Corydalis Decumbentis extract.

  2. Simultaneous targeted analysis of trimethylamine-N-oxide, choline, betaine, and carnitine by high performance liquid chromatography tandem mass spectrometry.

    PubMed

    Liu, Jia; Zhao, Mingming; Zhou, Juntuo; Liu, Changjie; Zheng, Lemin; Yin, Yuxin

    2016-11-01

    Trimethylamine-N-oxide (TMAO) is a metabolite generated from choline, betaine and carnitine in a gut microbiota-dependent way. This molecule is associated with development of atherosclerosis and cardiovascular events. A sensitive liquid chromatographic electrospray ionization tandem mass spectrometry (LC-ESI-MS/MS) has been developed and validated for the simultaneous determination of TMAO related molecules including TMAO, betaine, choline, and carnitine in mouse plasma. Analytes are extracted after protein precipitation by methanol and subjected to LC-ESI-MS/MS without preliminary derivatization. Separation of analytes was achieved on an amide column with acetonitrile-water as the mobile phase. This method has been fully validated in this study in terms of selectivity, linearity, sensitivity, precision, accuracy, and carryover effect, and the stability of the analyte under various conditions has been confirmed. This developed method has successfully been applied to plasma samples of our mouse model. Copyright © 2016 Elsevier B.V. All rights reserved.

  3. Laser-launched flyer plate and confined laser ablation for shock wave loading: validation and applications.

    PubMed

    Paisley, Dennis L; Luo, Sheng-Nian; Greenfield, Scott R; Koskelo, Aaron C

    2008-02-01

    We present validation and some applications of two laser-driven shock wave loading techniques: laser-launched flyer plate and confined laser ablation. We characterize the flyer plate during flight and the dynamically loaded target with temporally and spatially resolved diagnostics. With transient imaging displacement interferometry, we demonstrate that the planarity (bow and tilt) of the loading induced by a spatially shaped laser pulse is within 2-7 mrad (with an average of 4+/-1 mrad), similar to that in conventional techniques including gas gun loading. Plasma heating of target is negligible, in particular, when a plasma shield is adopted. For flyer plate loading, supported shock waves can be achieved. Temporal shaping of the drive pulse in confined laser ablation allows for flexible loading, e.g., quasi-isentropic, Taylor-wave, and off-Hugoniot loading. These techniques can be utilized to investigate such dynamic responses of materials as Hugoniot elastic limit, plasticity, spall, shock roughness, equation of state, phase transition, and metallurgical characteristics of shock-recovered samples.

  4. TnBP⁄Triton X-45 Treatment of Plasma for Transfusion Efficiently Inactivates Hepatitis C Virus

    PubMed Central

    Chou, Ming-Li; Burnouf, Thierry; Chang, Shun-Pang; Hung, Ting-Chun; Lin, Chun-Ching; Richardson, Christopher D.; Lin, Liang-Tzung

    2015-01-01

    Risk of transmission of hepatitis C virus (HCV) by clinical plasma remains high in countries with a high prevalence of hepatitis C, justifying the implementation of viral inactivation treatments. In this study, we assessed the extent of inactivation of HCV during minipool solvent/detergent (SD; 1% TnBP / 1% Triton X-45) treatment of human plasma. Luciferase-tagged infectious cell culture-derived HCV (HCVcc) particles were used to spike human plasma prior to treatment by SD at 31 ± 0.5°C for 30 min. Samples were taken before and after SD treatment and filtered on a Sep-Pak Plus C18 cartridge to remove the SD agents. Risk of cytotoxicity was assessed by XTT cell viability assay. Viral infectivity was analyzed based on the luciferase signals, 50% tissue culture infectious dose viral titer, and immunofluorescence staining for HCV NS5A protein. Total protein, cholesterol, and triglyceride contents were determined before and after SD treatment and C18 cartridge filtration. Binding analysis, using patient-derived HCV clinical isolates, was also examined to validate the efficacy of the inactivation by SD. SD treatment effectively inactivated HCVcc within 30 min, as demonstrated by the baseline level of reporter signals, total loss of viral infectivity, and absence of viral protein NS5A. SD specifically targeted HCV particles to render them inactive, with essentially no effect on plasma protein content and hemostatic function. More importantly, the efficacy of the SD inactivation method was confirmed against various genotypes of patient-derived HCV clinical isolates and against HCVcc infection of primary human hepatocytes. Therefore, treatment by 1% TnBP / 1% Triton X-45 at 31°C is highly efficient to inactivate HCV in plasma for transfusion, showing its capacity to enhance the safety of therapeutic plasma products. We propose that the methodology used here to study HCV infectivity can be valuable in the validation of viral inactivation and removal processes of human plasma-derived products. PMID:25658612

  5. Bioanalytical high-throughput selected reaction monitoring-LC/MS determination of selected estrogen receptor modulators in human plasma: 2000 samples/day.

    PubMed

    Zweigenbaum, J; Henion, J

    2000-06-01

    The high-throughput determination of small molecules in biological matrixes has become an important part of drug discovery. This work shows that increased throughput LC/MS/MS techniques can be used for the analysis of selected estrogen receptor modulators in human plasma where more than 2000 samples may be analyzed in a 24-h period. The compounds used to demonstrate the high-throughput methodology include tamoxifen, raloxifene, 4-hydroxytamoxifen, nafoxidine, and idoxifene. Tamoxifen and raloxifene are used in both breast cancer therapy and osteoporosis and have shown prophylactic potential for the reduction of the risk of breast cancer. The described strategy provides LC/MS/MS separation and quantitation for each of the five test articles in control human plasma. The method includes sample preparation employing liquid-liquid extraction in the 96-well format, an LC separation of the five compounds in less than 30 s, and selected reaction monitoring detection from low nano- to microgram per milliter levels. Precision and accuracy are determined where each 96-well plate is considered a typical "tray" having calibration standards and quality control (QC) samples dispersed through each plate. A concept is introduced where 24 96-well plates analyzed in 1 day is considered a "grand tray", and the method is cross-validated with standards placed only at the beginning of the first plate and the end of the last plate. Using idoxifene-d5 as an internal standard, the results obtained for idoxifene and tamoxifen satisfy current bioanalytical method validation criteria on two separate days where 2112 and 2304 samples were run, respectively. Method validation included 24-h autosampler stability and one freeze-thaw cycle stability for the extracts. Idoxifene showed acceptable results with accuracy ranging from 0.3% for the high quality control (QC) to 15.4% for the low QC and precision of 3.6%-13.9% relative standard deviation. Tamoxifen showed accuracy ranging from 1.6% to 13.8% and precision from 7.8% to 15.2%. The linear dynamic range for these compounds was 3 orders of magnitude. The limit of quantification was 5 and 50 ng/ mL for tamoxifen and idoxifene, respectively. The other compounds in this study in general satisfy the more relaxed bioanalytical acceptance criteria for modern drug discovery. It is suggested that the quantification levels reported in this high-throughput analysis example are adequate for many drug discovery and related early pharmaceutical studies.

  6. Matrix Extension and Multilaboratory Validation of Arsenic Speciation Method EAM §4.10 to Include Wine.

    PubMed

    Tanabe, Courtney K; Hopfer, Helene; Ebeler, Susan E; Nelson, Jenny; Conklin, Sean D; Kubachka, Kevin M; Wilson, Robert A

    2017-05-24

    A multilaboratory validation (MLV) was performed to extend the U.S. Food and Drug Administration's (FDA) analytical method Elemental Analysis Manual (EAM) §4.10, High Performance Liquid Chromatography-Inductively Coupled Plasma-Mass Spectrometric Determination of Four Arsenic Species in Fruit Juice, to include wine. Several method modifications were examined to optimize the method for the analysis of dimethylarsinic acid, monomethylarsonic acid, arsenate (AsV), and arsenite (AsIII) in various wine matrices with a range of ethanol concentrations by liquid chromatography-inductively coupled plasma-mass spectrometry. The optimized method was used for the analysis of five wines of different classifications (red, white, sparkling, rosé, and fortified) by three laboratories. Additionally, the samples were fortified in duplicate at levels of approximately 5, 10, and 30 μg kg -1 and analyzed by each participating laboratory. The combined average fortification recoveries of dimethylarsinic acid, monomethylarsonic acid, and inorganic arsenic (iAs the sum of AsV and AsIII) in these samples were 101, 100, and 100%, respectively. To further demonstrate the method, 46 additional wine samples were analyzed. The total As levels of all the wines analyzed in this study were between 1.0 and 38.2 μg kg -1 . The overall average mass balance based on the sum of the species recovered from the chromatographic separation compared to the total As measured was 89% with a range of 51-135%. In the 51 analyzed samples, iAs accounted for an average of 91% of the sum of the species with a range of 37-100%.

  7. Validation of a Rapid and Sensitive UPLC–MS-MS Method Coupled with Protein Precipitation for the Simultaneous Determination of Seven Pyrethroids in 100 µL of Rat Plasma by Using Ammonium Adduct as Precursor Ion

    PubMed Central

    Singh, Sheelendra Pratap; Dwivedi, Nistha; Raju, Kanumuri Siva Rama; Taneja, Isha; Wahajuddin, Mohammad

    2016-01-01

    United States Environmental Protection Agency has recommended estimating pyrethroids’ risk using cumulative exposure. For cumulative risk assessment, it would be useful to have a bioanalytical method for quantification of one or several pyrethroids simultaneously in a small sample volume to support toxicokinetic studies. Therefore, in the present study, a simple, sensitive and high-throughput ultraperformance liquid chromatography–tandem mass spectrometry method was developed and validated for simultaneous analysis of seven pyrethroids (fenvalerate, fenpropathrin, bifenthrin, lambda-cyhalothrin, cyfluthrin, cypermethrin and deltamethrin) in 100 µL of rat plasma. A simple single-step protein precipitation method was used for the extraction of target compounds. The total chromatographic run time of the method was 5 min. The chromatographic system used a Supelco C18 column and isocratic elution with a mobile phase consisting of methanol and 5 mM ammonium formate in the ratio of 90 : 10 (v/v). Mass spectrometer (API 4000) was operated in multiple reaction monitoring positive-ion mode using the electrospray ionization technique. The calibration curves were linear in the range of 7.8–2,000 ng/mL with correlation coefficients of ≥0.99. All validation parameters such as precision, accuracy, recovery, matrix effect and stability met the acceptance criteria according to the regulatory guidelines. The method was successfully applied to the toxicokinetic study of cypermethrin in rats. To the best of our knowledge, this is the first LC–MS-MS method for the simultaneous analysis of pyrethroids in rat plasma. This validated method with minimal modification can also be utilized for forensic and clinical toxicological applications due to its simplicity, sensitivity and rapidity. PMID:26801239

  8. Can Saliva and Plasma Methadone Concentrations Be Used for Enantioselective Pharmacokinetic and Pharmacodynamic Studies in Patients With Advanced Cancer?

    PubMed

    George, Rani; Haywood, Alison; Good, Phillip; Hennig, Stefanie; Khan, Sohil; Norris, Ross; Hardy, Janet

    2017-09-01

    Methadone is a potent analgesic used to treat refractory cancer pain. It is administered as a racemic mixture, with the l-enantiomer being primarily a μ-receptor agonist, whereas the d-enantiomer is an N-methyl-d-aspartate antagonist and inhibits serotonin and norepinephrine reuptake. Dose requirements vary greatly among patients to achieve optimal pain control and to avoid the risk of adverse effects. The relationship between plasma and saliva methadone enantiomer concentrations was investigated to determine if saliva could be a substitute for plasma in pharmacodynamic and pharmacokinetic studies for clinical monitoring and dose optimization of methadone in patients with advanced cancer. Patients with advanced cancer who were prescribed varying doses of oral methadone for pain management were recruited to obtain paired plasma and saliva samples. Pain scores were recorded at the time of sampling. The total and unbound plasma and saliva concentrations of the l- and d-enantiomers of methadone were quantified by using an HPLC-MS/MS method. The relationship between plasma (total and unbound) and saliva concentrations were compared. The saliva-to-plasma concentration ratio was compared versus the dose administered and the time after dosing for both enantiomers. The association of methadone concentrations with reported pain scores was compared by using a Mann-Whitney U test for significance. Fifty patients receiving a mean dose of 11mg/d of methadone provided 151 paired plasma and saliva samples. The median age of the population was 61 years with an interquartile range of 53-71 years with total body weight ranging from 59-88 kg. Median (interquartile) total plasma concentrations for l- and d-methadone were 50.78 ng/mL (30.6-113.0 ng/mL) and 62.0 ng/mL (28.7-116.0 ng/mL), respectively. Median (interquartile range) saliva concentrations for l- and d-methadone were 81.5 ng/mL (28.0-203.2 ng/mL) and 44.2 (16.2-149.7 ng/mL). No relationship could be established between plasma and saliva concentrations for l- and d-methadone (r 2 = 0.35 and 0.25). The saliva-to-plasma concentration analyzed with the methadone dose showed higher saliva concentrations at lower doses. Dose-normalized saliva concentrations followed a similar pattern over time compared with plasma concentrations. No correlation was found between l-methadone plasma, d-methadone plasma, l-methadone saliva, d-methadone saliva concentrations, and pain score. Saliva concentration was not a better predictor of pain control than plasma concentration for dose optimization and monitoring studies of methadone in patients with cancer. Although the saliva-to-plasma ratio of the concentration of methadone enantiomers was stable across the dosing range, due to the variability in individual saliva-to-plasma ratios, saliva sampling may not be a valid substitute in pharmacokinetic studies of methadone in cancer. Copyright © 2017 Elsevier HS Journals, Inc. All rights reserved.

  9. Quantification of Paclitaxel and Polyaspartate Paclitaxel Conjugate in Beagle Plasma: Application to a Pharmacokinetic Study.

    PubMed

    Gao, Yangyang; Chen, Junying; Zhang, Xiqian; Xie, Huiru; Wang, Yanran; Guo, Shuquan

    2017-03-01

    An LC-MS/MS method for the determination of polyaspartate paclitaxel conjugate (PASP-PTX) and paclitaxel (PTX) in dog plasma with cephalomannine (Internal Standard for PASP-PTX, IS-I) and clopidogrel bisulfate (Internal Standard for PTX, IS-II) as the internal standards was developed and validated. Plasma samples of PASP-PTX were extracted by ethyl acetate following the hydrolysis reaction, while protein precipitation was used for the extraction of PTX using acetonitrile. Analytes were separated by a CAPCELL PAK C18 MG II column using a gradient elution with the mobile phase (A) 5 mM ammonium containing 0.1% formic acid, and (B) acetonitrile. Quantification was performed by monitoring the m/z transitions of 286.2/105.0 for PASP-PTX, 264.2/83.0 for IS-I, 854.4/286.0 for PTX, and 322.1/184.1 for IS-II in the ESI positive mode. This method was validated in terms of specificity, linearity, precision, accuracy, and stability. The lower limit of quantification was 0.15 µg/mL for PASP-PTX and 0.01 µg/mL for PTX, and the calibration curves were linear over 0.15-300 µg/mL for PASP-PTX and over 0.01-10 µg/mL for PTX. The samples were stable under all the tested conditions. The method was successfully applied to study the pharmacokinetic profiles of PASP-PTX and PTX in beagles following intravenous administration of PASP-PTX. © The Author 2016. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.

  10. Screening for and validated quantification of amphetamines and of amphetamine- and piperazine-derived designer drugs in human blood plasma by gas chromatography/mass spectrometry.

    PubMed

    Peters, Frank T; Schaefer, Simone; Staack, Roland F; Kraemer, Thomas; Maurer, Hans H

    2003-06-01

    The classical stimulants amphetamine, methamphetamine, ethylamphetamine and the amphetamine-derived designer drugs MDA, MDMA ('ecstasy'), MDEA, BDB and MBDB have been widely abused for a relatively long time. In recent years, a number of newer designer drugs have entered the illicit drug market. 4-Methylthioamphetamine (MTA), p-methoxyamphetamine (PMA) and p-methoxymethamphetamine (PMMA) are also derived from amphetamine. Other designer drugs are derived from piperazine, such as benzylpiperazine (BZP), methylenedioxybenzylpiperazine (MDBP), trifluoromethylphenylpiperazine (TFMPP), m-chlorophenylpiperazine (mCPP) and p-methoxyphenylpiperazine (MeOPP). A number of severe or even fatal intoxications involving these newer substances, especially PMA, have been reported. This paper describes a method for screening for and simultaneous quantification of the above-mentioned compounds and the metabolites p-hydroxyamphetamine and p-hydroxymethamphetamine (pholedrine) in human blood plasma. The analytes were analyzed by gas chromatography/mass spectrometry in the selected-ion monitoring mode after mixed-mode solid-phase extraction (HCX) and derivatization with heptafluorobutyric anhydride. The method was fully validated according to international guidelines. It was linear from 5 to 1000 micro g l(-1) for all analytes. Data for accuracy and precision were within required limits with the exception of those for MDBP. The limit of quantification was 5 micro g l(-1) for all analytes. The applicability of the assay was proven by analysis of authentic plasma samples and of a certified reference sample. This procedure should also be suitable for confirmation of immunoassay results positive for amphetamines and/or designer drugs of the ecstasy type. Copyright 2003 John Wiley & Sons, Ltd.

  11. Elevated expression of CXC chemokines in pediatric osteosarcoma patients.

    PubMed

    Li, Yiting; Flores, Ricardo; Yu, Alexander; Okcu, M Fatih; Murray, Jeffrey; Chintagumpala, Murali; Hicks, John; Lau, Ching C; Man, Tsz-Kwong

    2011-01-01

    Osteosarcoma is the most common malignant bone tumor in children. Despite the advent of chemotherapy, the survival of osteosarcoma patients has not been significantly improved recently. Chemokines are a group of signaling molecules that have been implicated in tumorigenesis and metastasis. The authors used an antibody microarray to identify chemokines that were elevated in the plasma samples of osteosarcoma patients. The results were validated using enzyme-linked immunosorbent assays on an independent set of samples. The tumor expressions of 3 chemokines were examined in 2 sets of osteosarcoma tissue arrays. The authors also evaluated the proliferative effect of the chemokines in 4 osteosarcoma cell lines. The authors found that the plasma levels of CXCL4, CXCL6, and CXCL12 in the osteosarcoma patients were significantly higher than those in the controls, and the results were validated by an independent osteosarcoma cohort (P < .05). However, CXCL4 (100%) and CXCL6 (91%) were frequently expressed in osteosarcoma, whereas CXCL12 was only expressed in 4%. Survival analysis further showed that higher circulating levels of CXCL4 and CXCL6, but not CXCL12, were associated with a poorer outcome of osteosarcoma patients. Addition of exogenous chemokines significantly promoted the growth of different osteosarcoma cells (P < .05). The results demonstrate that CXCL4 and CXCL6 are frequently expressed in osteosarcoma, and that the plasma levels of these 2 chemokines are associated with patient outcomes. Further study of these circulating chemokines may provide a promising approach for prognostication of osteosarcoma. Targeting these chemokines or their receptors may also lead to a novel therapeutic invention. © 2010 American Cancer Society.

  12. Accurate detection of low prevalence AKT1 E17K mutation in tissue or plasma from advanced cancer patients

    PubMed Central

    de Bruin, Elza C.; Whiteley, Jessica L.; Corcoran, Claire; Kirk, Pauline M.; Fox, Jayne C.; Armisen, Javier; Lindemann, Justin P. O.; Schiavon, Gaia; Ambrose, Helen J.; Kohlmann, Alexander

    2017-01-01

    Personalized healthcare relies on accurate companion diagnostic assays that enable the most appropriate treatment decision for cancer patients. Extensive assay validation prior to use in a clinical setting is essential for providing a reliable test result. This poses a challenge for low prevalence mutations with limited availability of appropriate clinical samples harboring the mutation. To enable prospective screening for the low prevalence AKT1 E17K mutation, we have developed and validated a competitive allele-specific TaqMan® PCR (castPCR™) assay for mutation detection in formalin-fixed paraffin-embedded (FFPE) tumor tissue. Analysis parameters of the castPCR™ assay were established using an FFPE DNA reference standard and its analytical performance was assessed using 338 breast cancer and gynecological cancer FFPE samples. With recent technical advances for minimally invasive mutation detection in circulating tumor DNA (ctDNA), we subsequently also evaluated the OncoBEAM™ assay to enable plasma specimens as additional diagnostic opportunity for AKT1 E17K mutation testing. The analysis performance of the OncoBEAM™ test was evaluated using a novel AKT1 E17K ctDNA reference standard consisting of sheared genomic DNA spiked into human plasma. Both assays are employed at centralized testing laboratories operating according to quality standards for prospective identification of the AKT1 E17K mutation in ER+ breast cancer patients in the context of a clinical trial evaluating the AKT inhibitor AZD5363 in combination with endocrine (fulvestrant) therapy. PMID:28472036

  13. Evaluation of single-point sampling strategies for the estimation of moclobemide exposure in depressive patients.

    PubMed

    Ignjatovic, Anita Rakic; Miljkovic, Branislava; Todorovic, Dejan; Timotijevic, Ivana; Pokrajac, Milena

    2011-05-01

    Because moclobemide pharmacokinetics vary considerably among individuals, monitoring of plasma concentrations lends insight into its pharmacokinetic behavior and enhances its rational use in clinical practice. The aim of this study was to evaluate whether single concentration-time points could adequately predict moclobemide systemic exposure. Pharmacokinetic data (full 7-point pharmacokinetic profiles), obtained from 21 depressive inpatients receiving moclobemide (150 mg 3 times daily), were randomly split into development (n = 18) and validation (n = 16) sets. Correlations between the single concentration-time points and the area under the concentration-time curve within a 6-hour dosing interval at steady-state (AUC(0-6)) were assessed by linear regression analyses. The predictive performance of single-point sampling strategies was evaluated in the validation set by mean prediction error, mean absolute error, and root mean square error. Plasma concentrations in the absorption phase yielded unsatisfactory predictions of moclobemide AUC(0-6). The best estimation of AUC(0-6) was achieved from concentrations at 4 and 6 hours following dosing. As the most reliable surrogate for moclobemide systemic exposure, concentrations at 4 and 6 hours should be used instead of predose trough concentrations as an indicator of between-patient variability and a guide for dose adjustments in specific clinical situations.

  14. Discovery and Validation of Predictive Biomarkers of Survival for Non-small Cell Lung Cancer Patients Undergoing Radical Radiotherapy: Two Proteins With Predictive Value

    PubMed Central

    Walker, Michael J.; Zhou, Cong; Backen, Alison; Pernemalm, Maria; Williamson, Andrew J.K.; Priest, Lynsey J.C.; Koh, Pek; Faivre-Finn, Corinne; Blackhall, Fiona H.; Dive, Caroline; Whetton, Anthony D.

    2015-01-01

    Lung cancer is the most frequent cause of cancer-related death world-wide. Radiotherapy alone or in conjunction with chemotherapy is the standard treatment for locally advanced non-small cell lung cancer (NSCLC). Currently there is no predictive marker with clinical utility to guide treatment decisions in NSCLC patients undergoing radiotherapy. Identification of such markers would allow treatment options to be considered for more effective therapy. To enable the identification of appropriate protein biomarkers, plasma samples were collected from patients with non-small cell lung cancer before and during radiotherapy for longitudinal comparison following a protocol that carries sufficient power for effective discovery proteomics. Plasma samples from patients pre- and during radiotherapy who had survived > 18 mo were compared to the same time points from patients who survived < 14 mo using an 8 channel isobaric tagging tandem mass spectrometry discovery proteomics platform. Over 650 proteins were detected and relatively quantified. Proteins which showed a change during radiotherapy were selected for validation using an orthogonal antibody-based approach. Two of these proteins were verified in a separate patient cohort: values of CRP and LRG1 combined gave a highly significant indication of extended survival post one week of radiotherapy treatment. PMID:26425690

  15. Validated UHPLC-MS/MS assay for quantitative determination of etoposide, gemcitabine, vinorelbine and their metabolites in patients with lung cancer.

    PubMed

    Gong, Xiaobin; Yang, Le; Zhang, Feng; Liang, Youtian; Gao, Shouhong; Liu, Ke; Chen, Wansheng

    2017-11-01

    A fully valid UHPLC-MS/MS method was developed for the determination of etoposide, gemcitabine, vinorelbine and their metabolites (etoposide catechol, 2',2'-difluorodeoxyuridine and 4-O-deacetylvinorelbine) in human plasma. The multiple reaction monitoring mode was performed with an electrospray ionization interface operating in both the positive and negative ion modes per compound. The method required only 100 μL plasma with a one-step simple de-proteinization procedure, and a short run time of 7.5 min per sample. A Waters ACQUITY UPLC HSS T3 column (2.1 × 100 mm, 1.8 μm) provided chromatographic separation of analytes using a binary mobile phase gradient (A, 0.1% formic acid in acetonitrile, v/v; B, 0.1% formic acid in water, v/v). Linear coefficients of correlation were >0.995 for all analytes. The relative deviation of this method was <10% for intra- and inter-day assays and the accuracy ranged between 86.35% and 113.44%. The mean extraction recovery and matrix effect of all the analytes were 62.07-105.46% and 93.67-105.87%, respectively. This method was successfully applied to clinical samples from patients with lung cancer. Copyright © 2017 John Wiley & Sons, Ltd.

  16. Time effect and aliquot concentration in Streptococcus mutans elimination by plasma needle

    NASA Astrophysics Data System (ADS)

    García-Alcantara, E.; López-Callejas, R.; Peña-Eguiluz, R.; Lagunas-Bernabé, S.; Valencia-Alvarado, R.; Mercado-Cabrera, A.; Barocio, S. R.; Muñoz-Castro, A. E.; Rodríguez-Méndez, B. G.; de la Piedad-Beneitez, A.

    2012-06-01

    Atmospheric plasma needle systems are being intensively studied with a view to potential applications in medicine. The aim of this in vitro study is the improved elimination of Streptococcus Mutants (S. mutans) bacteria. A 5 ml volume of Luria-Bertani culture medium has been inoculated with a test bacterial population and incubated during 24 hours, followed by ten dilutions producing aliquots at 20, 50 and 100 micro l per dilution. Each aliquot is deposited on a paper filter and then exposed to a 2 W RF room pressure helium plasma needle discharge at a 1.5 l.p.m. rate for 1, 3, 5 or 7 minutes. Each sample paper is placed in a test tube, again containing Luria-Bertani fluid, in order to develop a new bacterium colony after a 24h incubation period. The plasma needle lethality has been evaluated from absorbance studies by means of a 6305 Jeway spectrophotometer at a 600 nm wavelength, indicating a clear correlation with exposure time. These studies validate the high disinfection efficacy of the plasma needle.

  17. Partnership for Edge Physics (EPSI), University of Texas Final Report

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Moser, Robert; Carey, Varis; Michoski, Craig

    Simulations of tokamak plasmas require a number of inputs whose values are uncertain. The effects of these input uncertainties on the reliability of model predictions is of great importance when validating predictions by comparison to experimental observations, and when using the predictions for design and operation of devices. However, high fidelity simulation of tokamak plasmas, particular those aimed at characterization of the edge plasma physics, are computationally expensive, so lower cost surrogates are required to enable practical uncertainty estimates. Two surrogate modeling techniques have been explored in the context of tokamak plasma simulations using the XGC family of plasma simulationmore » codes. The first is a response surface surrogate, and the second is an augmented surrogate relying on scenario extrapolation. In addition, to reduce the costs of the XGC simulations, a particle resampling algorithm was developed, which allows marker particle distributions to be adjusted to maintain optimal importance sampling. This means that the total number of particles in and therefore the cost of a simulation can be reduced while maintaining the same accuracy.« less

  18. Simple and sensitive HPLC method with fluorescence detection for the measurement of ibuprofen in rat plasma: application to a long-lasting dosage form.

    PubMed

    Hassan, Ahmed Sheikh; Sapin, Anne; Ubrich, Nathalie; Maincent, Philippe; Bolzan, Claire; Leroy, Pierre

    2008-10-01

    A simple and sensitive high-performance liquid chromatography (HPLC) assay applied to the measurement of ibuprofen in rat plasma has been developed. Two parameters have been investigated to improve ibuprofen detectability using fluorescence detection: variation of mobile phase pH and the use of beta-cyclodextrin (beta-CD). Increasing the pH value from 2.5 to 6.5 and adding 5 mM beta-CD enhanced the fluorescence signal (lambda(exc) = 224 nm; lambda(em) = 290 nm) by 2.5 and 1.3-fold, respectively, when using standards. In the case of plasma samples, only pH variation significantly lowered detection and quantification limits, down to 10 and 35 ng/mL, respectively. Full selectivity was obtained with a single step for plasma treatment, that is, protein precipitation with acidified acetonitrile. The validated method was applied to a pharmacokinetic study of ibuprofen encapsulated in microspheres and subcutaneously administered to rats.

  19. A sensitive liquid chromatography-mass spectrometry method for the simultaneous determination in plasma of pentacyclic triterpenes of Olea europaea L.

    PubMed

    Giménez, Estela; Juan, M Emília; Calvo-Melià, Sara; Planas, Joana M

    2017-08-15

    Table olives are especially rich in pentacyclic triterpenic compounds, which exert several biological activities. A crucial step in order to know if these compounds could contribute to the beneficial and healthy properties of this food is their measurement in blood. Therefore, the present study describes a simple and accurate liquid-liquid extraction followed by LC-QqQ-MS analysis for the simultaneous determination of the main pentacyclic triterpenes from Olea europaea L. in rat plasma. The method was validated by the analysis of blank plasma samples spiked with pure compounds, obtaining a linear correlation, adequate sensitivity with a limit of quantification ranging from 1nM for maslinic acid to 10nM for uvaol. Precision and accuracy were lower than 10% in all cases and recoveries were between 95 and 104%. The oral administration of olives to rats and its determination in plasma verified that the established methodology is appropriate for bioavailability studies. Copyright © 2017 Elsevier Ltd. All rights reserved.

  20. High-sensitive LC-MS/MS method for the simultaneous determination of mirodenafil and its major metabolite, SK-3541, in human plasma: application to microdose clinical trials of mirodenafil.

    PubMed

    Cho, Doo-Yeoun; Bae, Soo Hyeon; Shon, Ji-Hong; Bae, Soo Kyung

    2013-03-01

    A high-sensitivity LC/MS/MS method was developed and validated for the simultaneous determination of mirodenafil and its major metabolite, SK-3541, in human plasma. Mirodenafil, SK-3541, and udenafil as an internal standard were extracted from plasma samples with methyl tert-butyl ether. Chromatographic separation was performed on a Luna phenyl-hexyl column (100 × 2.0 mm) with an isocratic mobile phase consisting of 5 mM ammonium formate and ACN (23:77, v/v) at a flow rate of 0.35 mL/min. Detection and quantification were performed using a mass spectrometer in selected reaction monitoring mode with positive ESI at m/z 532.3 → 296.1 for mirodenafil, m/z 488.1 → 296.1 for SK-3541, and m/z 517.3 → 283.2 for udenafil. The calibration curves were linear over a concentration range of 2-500 pg/mL using 0.5 mL plasma for the microdose of mirodenafil (100 μg). Analytical method validation of the clinical dose (100 mg), with a calibration curve range of 2-500 ng/mL using 0.025-mL plasma, was also conducted. The other LC-MS/MS conditions were similar to those used for the microdosing. Each method was applied successfully to pharmacokinetic studies after a microdose or clinical dose of mirodenafil to six healthy Korean male volunteers. © 2013 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  1. Rapid and sensitive liquid chromatography-tandem mass spectrometry method for determination of protein-free pro-drug treosulfan and its biologically active monoepoxy-transformer in plasma and brain tissue.

    PubMed

    Romański, Michał; Teżyk, Artur; Zaba, Czesław; Główka, Franciszek K

    2014-09-01

    For the first time a high performance liquid chromatography method with tandem mass spectrometry detection (HPLC-MS/MS) was developed for simultaneous determination of a pro-drug treosulfan (TREO) and its active monoepoxide (S,S-EBDM) in biological matrices. Small volumes of rat plasma (50 μL) and the brain homogenate supernatant (100 μL), equivalent to 0.02 g of brain tissue, were required for the analysis. Protein-free TREO, S,S-EBDM and acetaminophen, internal standard (IS), were isolated from the samples by ultrafiltration. Complete resolution of the analytes and the IS was accomplished on Zorbax Eclipse column using an isocratic elution with a mobile phase composed of ammonium formate - formic acid buffer pH 4.0 and acetonitrile. Detection was performed on a triple-quadrupole MS via multiple-reaction-monitoring following electrospray ionization. The developed method was fully validated according to the current guidelines of the European Medicines Agency. Calibration curves were linear in ranges: TREO 0.2-5720 μM and S,S-EBDM 0.9-175 μM for plasma, and TREO 0.2-29 μM and S,S-EBDM 0.4-44 μM for the brain homogenate supernatant. The limits of quantitation of TREO and S,S-EBDM in the studied matrices were much lower in comparison to the previously used bioanalytical methods. The HPLC-MS/MS method was adequately precise (coefficient of variation≤12.2%), accurate (relative error≤8.6%), and provided no carry-over, acceptable matrix effect as well as dilution integrity. The analytes were stable in acidified plasma and the brain homogenate supernatant samples for 4 h at room temperature, for 4 months at-80°C as well as within two cycles of freezing and thawing, and demonstrated 18-24h autosampler stability. The validated method enabled determination of low concentrations of TREO and S,S-EBDM in incurred brain samples of the rats treated with TREO, which constitutes a novel bioanalytical application. Copyright © 2014 Elsevier B.V. All rights reserved.

  2. Preparation of immunochromatographic strips for rapid detection of early secreted protein ESAT-6 and culture filtrate protein CFP-10 from Mycobacterium tuberculosis

    PubMed Central

    Wu, Xiaoxin; Wang, Yeping; Weng, Tianhao; Hu, Chenyu; Wang, Frederick X.C.; Wu, Zhigang; Yu, Dongshan; Lu, Huoquan; Yao, Hangping

    2017-01-01

    Abstract The early secreted protein early secretory antigenic target 6(ESAT-6) and the culture filtrate protein 10 (CFP-10) are 2 antigens that are specific to Mycobacterium tuberculosis. These 2 antigens are good targets for tuberculosis (TB) detection. To rapidly diagnose TB across a variety of samples, we developed colloidal gold immunochromatographic strips (ICSs) based on ESAT-6 and CFP-10. The strips were evaluated using 233 samples, including sputum, plasma, and pleural effusion samples. The positive detection rates for ICSs for ESAT-6 and CFP-10 in sputum (culture-positive for M tuberculosis) were 100% and 91.2%, respectively. The positive detection rates for ICSs for ESAT-6 and CFP-10 in plasma were 34.1% and 29.4%, respectively. The positive detection rates for ICSs for ESAT-6 and CFP-10 in pleural effusion were 64.7% and 55.9%, respectively. Experimental analysis of culture supernatant showing that the ICS developed for ESAT-6 had a sensitivity of 100% and a specificity of 91.2%. While the ICS developed for CFP-10 had a sensitivity of 91.2% and a specificity of 88.2%. The validity of the test is limited by source of sample. The technique is sensitive and specific for samples in sputum and culture media but not for plasma or pleural effusion samples. Detection of M tuberculosis using ICSs is rapid, simple, and relatively effective; thus, ICSs are a potential screening tool for TB. PMID:29390519

  3. Anti-glucagon-like peptide-1 immunoreactivity in samples of blood and ileum obtained from neonatal and adult alpacas.

    PubMed

    Smith, Courtney C; Cebra, Christopher K; Heidel, Jerry R; Stang, Bernadette V

    2013-11-01

    To compare numbers of L cells in intestinal samples and blood concentrations of glucagon-like peptide (GLP)-1 between neonatal and mature alpacas. Intestinal samples from carcasses of 4 suckling crias and 4 postweaning alpacas for immunohistochemical analysis and blood samples from 32 suckling crias and 19 healthy adult alpacas for an ELISA. Immunohistochemical staining was conducted in accordance with Oregon State University Veterinary Diagnostic Laboratory standard procedures with a rabbit polyclonal anti-GLP-1 primary antibody. Stained cells with staining results in ileal tissue were counted in 20 fields by 2 investigators, and the mean value was calculated. For quantification of GLP-1 concentrations, blood samples were collected into tubes containing a dipeptidyl peptidase-4 inhibitor. Plasma samples were tested in duplicate with a commercial GLP-1 ELISA validated for use in alpacas. Counts of stained cells (mean ± SD, 50 ± 18 cells) and plasma GLP-1 concentrations (median, 0.086 ng/mL; interquartile range, 0.061 to 0.144 ng/mL) were higher for suckling alpacas than for postsuckling alpacas (stained cells, 26 ± 4 cells; plasma GLP-1 concentration, median, 0.034 ng/mL; interquartile range, 0.015 to 0.048 ng/mL). Older alpacas had lower numbers of L cells in intestinal tissues and lower blood concentrations of GLP-1 than those in neonates. These findings suggested that there may be a decrease in the contribution of GLP-1 to insulin production in adult alpacas, compared with the contribution in neonates.

  4. Bioanalysis works in the IAA AMS facility: Comparison of AMS analytical method with LSC method in human mass balance study

    NASA Astrophysics Data System (ADS)

    Miyaoka, Teiji; Isono, Yoshimi; Setani, Kaoru; Sakai, Kumiko; Yamada, Ichimaro; Sato, Yoshiaki; Gunji, Shinobu; Matsui, Takao

    2007-06-01

    Institute of Accelerator Analysis Ltd. (IAA) is the first Contract Research Organization in Japan providing Accelerator Mass Spectrometry (AMS) analysis services for carbon dating and bioanalysis works. The 3 MV AMS machines are maintained by validated analysis methods using multiple control compounds. It is confirmed that these AMS systems have reliabilities and sensitivities enough for each objective. The graphitization of samples for bioanalysis is prepared by our own purification lines including the measurement of total carbon content in the sample automatically. In this paper, we present the use of AMS analysis in human mass balance and metabolism profiling studies with IAA 3 MV AMS, comparing results obtained from the same samples with liquid scintillation counting (LSC). Human samples such as plasma, urine and feces were obtained from four healthy volunteers orally administered a 14C-labeled drug Y-700, a novel xanthine oxidase inhibitor, of which radioactivity was about 3 MBq (85 μCi). For AMS measurement, these samples were diluted 100-10,000-fold with pure-water or blank samples. The results indicated that AMS method had a good correlation with LSC method (e.g. plasma: r = 0.998, urine: r = 0.997, feces: r = 0.997), and that the drug recovery in the excreta exceeded 92%. The metabolite profiles of plasma, urine and feces obtained with HPLC-AMS corresponded to radio-HPLC results measured at much higher radioactivity level. These results revealed that AMS analysis at IAA is useful to measure 14C-concentration in bioanalysis studies at very low radioactivity level.

  5. Preparation of immunochromatographic strips for rapid detection of early secreted protein ESAT-6 and culture filtrate protein CFP-10 from Mycobacterium tuberculosis.

    PubMed

    Wu, Xiaoxin; Wang, Yeping; Weng, Tianhao; Hu, Chenyu; Wang, Frederick X C; Wu, Zhigang; Yu, Dongshan; Lu, Huoquan; Yao, Hangping

    2017-12-01

    The early secreted protein early secretory antigenic target 6(ESAT-6) and the culture filtrate protein 10 (CFP-10) are 2 antigens that are specific to Mycobacterium tuberculosis. These 2 antigens are good targets for tuberculosis (TB) detection.To rapidly diagnose TB across a variety of samples, we developed colloidal gold immunochromatographic strips (ICSs) based on ESAT-6 and CFP-10.The strips were evaluated using 233 samples, including sputum, plasma, and pleural effusion samples.The positive detection rates for ICSs for ESAT-6 and CFP-10 in sputum (culture-positive for M tuberculosis) were 100% and 91.2%, respectively. The positive detection rates for ICSs for ESAT-6 and CFP-10 in plasma were 34.1% and 29.4%, respectively. The positive detection rates for ICSs for ESAT-6 and CFP-10 in pleural effusion were 64.7% and 55.9%, respectively. Experimental analysis of culture supernatant showing that the ICS developed for ESAT-6 had a sensitivity of 100% and a specificity of 91.2%. While the ICS developed for CFP-10 had a sensitivity of 91.2% and a specificity of 88.2%.The validity of the test is limited by source of sample. The technique is sensitive and specific for samples in sputum and culture media but not for plasma or pleural effusion samples. Detection of M tuberculosis using ICSs is rapid, simple, and relatively effective; thus, ICSs are a potential screening tool for TB. Copyright © 2017 The Authors. Published by Wolters Kluwer Health, Inc. All rights reserved.

  6. Development of analytical methods for multiplex bio-assay with inductively coupled plasma mass spectrometry.

    PubMed

    Ornatsky, Olga I; Kinach, Robert; Bandura, Dmitry R; Lou, Xudong; Tanner, Scott D; Baranov, Vladimir I; Nitz, Mark; Winnik, Mitchell A

    2008-01-01

    Advances in the development of highly multiplexed bio-analytical assays with inductively coupled plasma mass spectrometry (ICP-MS) detection are discussed. Use of novel reagents specifically designed for immunological methods utilizing elemental analysis is presented. The major steps of method development, including selection of elements for tags, validation of tagged reagents, and examples of multiplexed assays, are considered in detail. The paper further describes experimental protocols for elemental tagging of antibodies, immunostaining of live and fixed human leukemia cells, and preparation of samples for ICP-MS analysis. Quantitative analysis of surface antigens on model cell lines using a cocktail of seven lanthanide labeled antibodies demonstrated high specificity and concordance with conventional immunophenotyping.

  7. HIV-1 tropism testing in subjects achieving undetectable HIV-1 RNA: diagnostic accuracy, viral evolution and compartmentalization.

    PubMed

    Pou, Christian; Codoñer, Francisco M; Thielen, Alexander; Bellido, Rocío; Pérez-Álvarez, Susana; Cabrera, Cecilia; Dalmau, Judith; Curriu, Marta; Lie, Yolanda; Noguera-Julian, Marc; Puig, Jordi; Martínez-Picado, Javier; Blanco, Julià; Coakley, Eoin; Däumer, Martin; Clotet, Bonaventura; Paredes, Roger

    2013-01-01

    Technically, HIV-1 tropism can be evaluated in plasma or peripheral blood mononuclear cells (PBMCs). However, only tropism testing of plasma HIV-1 has been validated as a tool to predict virological response to CCR5 antagonists in clinical trials. The preferable tropism testing strategy in subjects with undetectable HIV-1 viremia, in whom plasma tropism testing is not feasible, remains uncertain. We designed a proof-of-concept study including 30 chronically HIV-1-infected individuals who achieved HIV-1 RNA <50 copies/mL during at least 2 years after first-line ART initiation. First, we determined the diagnostic accuracy of 454 and population sequencing of gp120 V3-loops in plasma and PBMCs, as well as of MT-2 assays before ART initiation. The Enhanced Sensitivity Trofile Assay (ESTA) was used as the technical reference standard. 454 sequencing of plasma viruses provided the highest agreement with ESTA. The accuracy of 454 sequencing decreased in PBMCs due to reduced specificity. Population sequencing in plasma and PBMCs was slightly less accurate than plasma 454 sequencing, being less sensitive but more specific. MT-2 assays had low sensitivity but 100% specificity. Then, we used optimized 454 sequence data to investigate viral evolution in PBMCs during viremia suppression and only found evolution of R5 viruses in one subject. No de novo CXCR4-using HIV-1 production was observed over time. Finally, Slatkin-Maddison tests suggested that plasma and cell-associated V3 forms were sometimes compartmentalized. The absence of tropism shifts during viremia suppression suggests that, when available, testing of stored plasma samples is generally safe and informative, provided that HIV-1 suppression is maintained. Tropism testing in PBMCs may not necessarily produce equivalent biological results to plasma, because the structure of viral populations and the diagnostic performance of tropism assays may sometimes vary between compartments. Thereby, proviral DNA tropism testing should be specifically validated in clinical trials before it can be applied to routine clinical decision-making.

  8. Validation and implementation of liquid chromatographic-mass spectrometric (LC-MS) methods for the quantification of tenofovir prodrugs.

    PubMed

    Hummert, Pamela; Parsons, Teresa L; Ensign, Laura M; Hoang, Thuy; Marzinke, Mark A

    2018-04-15

    The nucleotide reverse transcriptase inhibitor tenofovir (TFV) is widely administered in a disoproxil prodrug form (tenofovir disoproxil fumarate, TDF) for HIV management and prevention. Recently, novel prodrugs tenofovir alafenamide fumarate (TAF) and hexadecyloxypropyl tenofovir (CMX157) have been pursued for HIV treatment while minimizing adverse effects associated with systemic TFV exposure. Dynamic and sensitive bioanalytical tools are required to characterize the pharmacokinetics of these prodrugs in systemic circulation. Two parallel methods have been developed, one to combinatorially quantify TAF and TFV, and a second method for CMX157 quantification, in plasma. K 2 EDTA plasma was spiked with TAF and TFV, or CMX157. Following the addition of isotopically labeled internal standards and sample extraction via solid phase extraction (TAF and TFV) or protein precipitation (CMX157), samples were subjected to liquid chromatographic-tandem mass spectrometric (LC-MS/MS) analysis. For TAF and TFV, separation occurred using a Zorbax Eclipse Plus C18 Narrow Bore RR, 2.1 × 50 mm, 3.5 μm column and analytes were detected on an API5000 mass analyzer; CMX157 was separated using a Kinetex C8, 2.1 × 50 mm, 2.6 μm column and quantified using an API4500 mass spectrometer. Methods were validated according to FDA Bioanalytical Method Validation guidelines. Analytical methods: were optimized for the multiplexed monitoring of TAF and TFV, and CMX157 in plasma. The lower limits of quantification (LLOQs) for TAF, TFV, and CMX157 were 0.03, 1.0, and 0.25 ng/mL, respectively. Calibration curves were generated via weighted linear regression of standards. Intra- and inter-assay precision and accuracy studies demonstrated %CVs ≤ 14.4% and %DEVs ≤ ± 7.95%, respectively. Stability and matrix effects studies were also performed. All results were acceptable and in accordance with the recommended guidelines for bioanalytical methods. Assays were also applied to quantify in vivo concentrations of prodrugs and TFV in a preclinical study post-rectal administration. Sensitive, specific, and dynamic LC-MS/MS assays have been developed and validated for the multiplexed quantification TAF and TFV, as well as an independent assay for CMX157 quantification, in plasma. The described methods meet sufficient throughput criteria to support large research trials. Copyright © 2018 Elsevier B.V. All rights reserved.

  9. Sex assignment of lake sturgeon (Acipenser fluvescens) based on plasma sex hormone and vitellogenin levels

    USGS Publications Warehouse

    Craig, J.M.; Papoulias, D.M.; Thomas, M.V.; Annis, M.L.; Boase, J.

    2009-01-01

    This study focused on identifying the sex of lake sturgeon by measuring the sex hormones estradiol and testosterone, and the phosphoprotein vitellogenin (Vtg) in blood plasma by radioimmunoassay and enzyme-linked immunosorbent assay, respectively, and evaluating these techniques as tools in lake sturgeon population management. Surveys of the St Clair River (SCR) lake sturgeon population have characterized it as rebounding by having steady or increasing recruitment since 1997. However, researchers have not been able to effectively determine the sex for most of the sturgeon they capture because few fish caught during surveys are releasing gametes. A total of 115 fish were sampled from May through June in 2004 and 2005 from the SCR, Michigan, USA. Of these, only four females and eight males were verified (i.e. they were releasing gametes at time of capture), resulting in very few fish with which to validate blood hormone and Vtg biomarkers of sex. Fifty-six percent of the fish were assigned a sex designation based on biomarker criteria. Correspondence between actual gonadal sex and biomarker-directed classification was good for the small subset of fish for which gonadal sex was definitively determined. Moreover, application of the steroid values in a predictive sex assignment model developed for white sturgeon misclassified only the same two fish that were misclassified with the steroid and Vtg biomarkers. The experimental results suggest a sex ratio of 1 : 2.7 (F:M), however more conclusive methods are needed to confirm this ratio because so few fish were available for sex validation. Of the 43 males, 14 were within the legal slot limit, 11 were smaller than 1067 mm total length (TL), and 18 were larger than 1270 mm TL. All 15 females were larger than 1270 mm TL, and thus protected by the slot limit criteria. Considering that lake sturgeon are threatened in Michigan, an advantage to using blood plasma assays was that fish were not harmed, and sample collection was quick, simple, and inexpensive. However, because a sufficiently large number of fish could not be validated for gonadal sex due to handling restrictions given the fish's protected status, assignment of sex is not based on a robust multi-variate model. An immediate alternative may be to use other non-invasive field methods (e.g. ultrasound, fiber-optic endoscope) to provide a more timely classification while establishing well-validated plasma hormone and Vtg-based predictive models for sex assignment of lake sturgeon. ?? 2009 Blackwell Verlag, Berlin.

  10. Precise Analysis of Gallium Isotopic Composition by MC-ICP-MS.

    PubMed

    Yuan, Wei; Chen, Jiu Bin; Birck, Jean-Louis; Yin, Zuo Ying; Yuan, Sheng Liu; Cai, Hong Ming; Wang, Zhong Wei; Huang, Qiang; Wang, Zhu Hong

    2016-10-04

    Though an isotope approach could be beneficial for better understanding the biogeochemical cycle of gallium (Ga), an analogue of the monoisotopic element aluminum (Al), the geochemistry of Ga isotopes has not been widely elaborated. We developed a two-step method for purifying Ga from geological (biological) samples for precise measurement of Ga isotope ratio using multicollector inductively coupled plasma mass spectrometry (MC-ICP-MS). Ga was thoroughly separated from other matrix elements using two chromatographic columns loaded with AG 1-X4 and Ln-spec resin, respectively. The separation method was carefully calibrated using both synthetic and natural samples and validated by assessing the extraction yield (99.8 ± 0.8%, 2SD, n = 23) and the reproducibility (2SD uncertainty better than 0.05‰, n = 116) of the measured isotopic ratio (expressed as δ 71 Ga). The validation of the whole protocol, together with instrumental analysis, was confirmed by the investigation of the matrix effect, the result of a standard addition experiment, and the comparison of Ga isotope measurement on two mass spectrometers-Nu Plasma II and Neptune Plus. Although the measurements using the sample-standard bracketing (SSB) correction method on both instruments resulted in identical δ 71 Ga values for reference materials, the modified empirical external normalization (MEEN) method gave relatively better precision compared to SSB on Neptune. Our preliminary results showed large variation of δ 71 Ga (up to 1.83‰) for 10 standards, with higher values in industrially produced materials, implying potential application of Ga isotopes.

  11. Analytical strategy for the determination of non-steroidal anti-inflammatory drugs in plasma and improved analytical strategy for the determination of authorized and non-authorized non-steroidal anti-inflammatory drugs in milk by LC-MS/MS.

    PubMed

    Dowling, Geraldine; Malone, Edward; Harbison, Tom; Martin, Sheila

    2010-07-01

    A sensitive and selective method for the determination of six non-steroidal anti-inflammatory drugs (NSAIDs) in bovine plasma was developed. An improved method for the determination of authorized and non-authorized residues of 10 non-steroidal anti-inflammatory drugs in milk was developed. Analytes were separated and acquired by high performance liquid chromatography coupled with an electrospray ionisation tandem mass spectrometer (ESI-MS/MS). Target compounds were acidified in plasma, and plasma and milk samples were extracted with acetonitrile and both extracts were purified on an improved solid phase extraction procedure utilising Evolute ABN cartridges. The accuracy of the methods for milk and plasma was between 73 and 109%. The precision of the method for authorized and non-authorized NSAIDs in milk and plasma expressed as % RSD, for the within lab reproducibility was less than 16%. The % RSD for authorized NSAIDs at their associated MRL(s) in milk was less than 10% for meloxicam, flunixin and tolfenamic acid and was less than 25% for hydroxy flunixin. The methods were validated according to Commission Decision 2002/657/EC.

  12. Three-Dimensionally Functionalized Reverse Phase Glycoprotein Array for Cancer Biomarker Discovery and Validation.

    PubMed

    Pan, Li; Aguilar, Hillary Andaluz; Wang, Linna; Iliuk, Anton; Tao, W Andy

    2016-11-30

    Glycoproteins have vast structural diversity that plays an important role in many biological processes and have great potential as disease biomarkers. Here, we report a novel functionalized reverse phase protein array (RPPA), termed polymer-based reverse phase glycoprotein array (polyGPA), to capture and profile glycoproteomes specifically, and validate glycoproteins. Nitrocellulose membrane functionalized with globular hydroxyaminodendrimers was used to covalently capture preoxidized glycans on glycoproteins from complex protein samples such as biofluids. The captured glycoproteins were subsequently detected using the same validated antibodies as in RPPA. We demonstrated the outstanding specificity, sensitivity, and quantitative capabilities of polyGPA by capturing and detecting purified as well as endogenous α-1-acid glycoprotein (AGP) in human plasma. We further applied quantitative N-glycoproteomics and the strategy to validate a panel of glycoproteins identified as potential biomarkers for bladder cancer by analyzing urine glycoproteins from bladder cancer patients or matched healthy individuals.

  13. Hydrophilic interaction liquid chromatography/positive ion electrospray ionization mass spectrometry method for the quantification of alprazolam and α-hydroxy-alprazolam in human plasma.

    PubMed

    Kalogria, Eleni; Pistos, Constantinos; Panderi, Irene

    2013-12-30

    A hydrophilic interaction liquid chromatography/positive ion electrospray-mass spectrometry (HILIC-ESI/MS) has been developed and fully validated for the quantification of alprazolam and its main metabolite, α-hydroxy-alprazolam, in human plasma. The assay is based on 50μL plasma samples, following liquid-liquid extraction. All analytes and the internal standard (tiamulin) were separated by hydrophilic interaction liquid chromatography using an X-Bridge-HILIC analytical column (150.0mm×2.1mm i.d., particle size 3.5μm) under isoscratic elution. The mobile phase was composed of a 7% 10mM ammonium formate water solution in acetonitrile and pumped at a flow rate of 0.20mLmin(-1). Running in positive electrospray ionization and selected ion monitoring (SIM) the mass spectrometer was set to analyze the protonated molecules [M+H](+) at m/z 309, 325 and 494 for alprazolam, α-hydroxy-alprazolam and tiamulin (ISTD) respectively. The assay was linear over the concentration range of 2.5-250ngmL(-1) for alprazolam and 2.5-50ngmL(-1) for α-hydroxy alprazolam. Intermediate precision was less than 4.1% over the tested concentration ranges. The method is the first reported application of HILIC in the analysis benzodiazepines in human plasma. With a small sample size (50μL human plasma) and a run time less than 10.0min for each sample the method can be used to support a wide range of clinical studies concerning alprazolam quantification. Copyright © 2013 Elsevier B.V. All rights reserved.

  14. Comparative Studies of the Proteome, Glycoproteome, and N-Glycome of Clear Cell Renal Cell Carcinoma Plasma before and after Curative Nephrectomy

    PubMed Central

    2015-01-01

    Clear cell renal cell carcinoma is the most prevalent of all reported kidney cancer cases, and currently there are no markers for early diagnosis. This has stimulated great research interest recently because early detection of the disease can significantly improve the low survival rate. Combining the proteome, glycoproteome, and N-glycome data from clear cell renal cell carcinoma plasma has the potential of identifying candidate markers for early diagnosis and prognosis and/or to monitor disease recurrence. Here, we report on the utilization of a multi-dimensional fractionation approach (12P-M-LAC) and LC–MS/MS to comprehensively investigate clear cell renal cell carcinoma plasma collected before (disease) and after (non-disease) curative nephrectomy (n = 40). Proteins detected in the subproteomes were investigated via label-free quantification. Protein abundance analysis revealed a number of low-level proteins with significant differential expression levels in disease samples, including HSPG2, CD146, ECM1, SELL, SYNE1, and VCAM1. Importantly, we observed a strong correlation between differentially expressed proteins and clinical status of the patient. Investigation of the glycoproteome returned 13 candidate glycoproteins with significant differential M-LAC column binding. Qualitative analysis indicated that 62% of selected candidate glycoproteins showed higher levels (upregulation) in M-LAC bound fraction of disease samples. This observation was further confirmed by released N-glycans data in which 53% of identified N-glycans were present at different levels in plasma in the disease vs non-disease samples. This striking result demonstrates the potential for significant protein glycosylation alterations in clear cell renal cell carcinoma cancer plasma. With future validation in a larger cohort, information derived from this study may lead to the development of clear cell renal cell carcinoma candidate biomarkers. PMID:25184692

  15. Measurement of titanium in hip-replacement patients by inductively coupled plasma optical emission spectroscopy.

    PubMed

    Harrington, Chris F; McKibbin, Craig; Rahanu, Monika; Langton, David; Taylor, Andrew

    2017-05-01

    Background Patients with metal-on-metal hip replacements require testing for cobalt and chromium. There may also be a need to test for titanium, which is used in the construction of the femoral stem in total hip replacements. It is not possible to use quadrupole inductively coupled plasma mass spectrometry due to interferences. Methods Titanium was measured using inductively coupled plasma optical emission spectroscopy using the emission line at 336.1 nm and Y (internal standard) at 371.0 nm. Internal quality control materials were prepared for blood and serum and concentrations assigned using a sector field-inductively coupled plasma mass spectrometer. A candidate whole blood certified reference material was also evaluated. Results The method had detection and quantitation limits of 0.6 and 1.9 µg/L, respectively. The respective bias (%) and measurement uncertainty ( U) (k = 2) were 3.3% and 2.0 µg/L (serum) and - 1.0% and 1.4 µg/L (whole blood). The respective repeatability and intermediate precision (%) were 5.1% and 10.9% (serum) and 2.4% and 8.6% (whole blood). The concentration of titanium was determined in patients' samples, serum (median = 2.4 µg/L, n = 897) and whole blood (median = 2.4 µg/L, n = 189). Serum is recommended for monitoring titanium in patients, since the concentration is higher than in whole blood and the matrix less problematic. In hip fluid samples, the concentrations were much higher (mean 58.5 µg/L, median 5.1 µg/L, n = 83). Conclusions A method based on inductively coupled plasma optical emission spectroscopy was developed and validated for measuring titanium in clinical samples.

  16. Doping control analysis of 46 polar drugs in horse plasma and urine using a 'dilute-and-shoot' ultra high performance liquid chromatography-high resolution mass spectrometry approach.

    PubMed

    Kwok, Wai Him; Choi, Timmy L S; Kwok, Karen Y; Chan, George H M; Wong, Jenny K Y; Wan, Terence S M

    2016-06-17

    The high sensitivity of ultra high performance liquid chromatography coupled with high resolution mass spectrometry (UHPLC-HRMS) allows the identification of many prohibited substances without pre-concentration, leading to the development of simple and fast 'dilute-and-shoot' methods for doping control for human and equine sports. While the detection of polar drugs in plasma and urine is difficult using liquid-liquid or solid-phase extraction as these substances are poorly extracted, the 'dilute-and-shoot' approach is plausible. This paper describes a 'dilute-and-shoot' UHPLC-HRMS screening method to detect 46 polar drugs in equine urine and plasma, including some angiotensin-converting enzyme (ACE) inhibitors, sympathomimetics, anti-epileptics, hemostatics, the new doping agent 5-aminoimidazole-4-carboxamide-1-β-d-ribofuranoside (AICAR), as well as two threshold substances, namely dimethyl sulfoxide and theobromine. For plasma, the sample (200μL) was protein precipitated using trichloroacetic acid, and the resulting supernatant was diluted using Buffer A with an overall dilution factor of 3. For urine, the sample (20μL) was simply diluted 50-fold with Buffer A. The diluted plasma or urine sample was then analysed using a UHPLC-HRMS system in full-scan ESI mode. The assay was validated for qualitative identification purpose. This straightforward and reliable approach carried out in combination with other screening procedures has increased the efficiency of doping control analysis in the laboratory. Moreover, since the UHPLC-HRMS data were acquired in full-scan mode, the method could theoretically accommodate an unlimited number of existing and new doping agents, and would allow a retrospectively search for drugs that have not been targeted at the time of analysis. Copyright © 2016 Elsevier B.V. All rights reserved.

  17. A simple LC-MS/MS method using HILIC chromatography for the determination of fosfomycin in plasma and urine: application to a pilot pharmacokinetic study in humans.

    PubMed

    Parker, Suzanne L; Lipman, Jeffrey; Roberts, Jason A; Wallis, Steven C

    2015-02-01

    A high performance liquid chromatography-tandem mass spectrometry (LC-MS/MS) method, using hydrophilic interaction liquid chromatography (HILIC) chromatography for the analysis of fosfomycin in human plasma and urine, has been developed and validated. The plasma method uses a simple protein precipitation using a low volume sample (10 μL) and is suitable for the concentration range of 1 to 2000 μg/mL. The urine method involves a simple dilution of 10 μL of sample and is suitable for a concentration range of 0.1 to 10 mg/mL. The plasma and urine results, reported, respectively, are for recovery (68, 72%), inter-assay precision (≤9.1%, ≤8.1%) and accuracy (range -7.2 to 3.3%, -1.9 to 1.6%), LLOQ precision (4.7%, 3.1%) and accuracy (1.7% and 1.2%), and includes investigations into the linearity, stability and matrix effects. The method was used in a pilot pharmacokinetic study of a critically ill patient receiving i.v. fosfomycin, which measured a maximum and minimum plasma concentration of 222 μg/mL and 172 μg/mL, respectively, after the initial dose, and a maximum and minimum plasma concentration of 868 μg/mL and 591μg/mL, respectively, after the fifth dose. The urine concentration was 2.03 mg/mL after the initial dose and 0.29 mg/mL after the fifth dose. Copyright © 2014 Elsevier B.V. All rights reserved.

  18. Investigation of Metabolomic Blood Biomarkers for Detection of Adenocarcinoma Lung Cancer

    PubMed Central

    Fahrmann, Johannes F.; Kim, Kyoungmi; DeFelice, Brian C.; Taylor, Sandra L.; Gandara, David R.; Yoneda, Ken Y.; Cooke, David T.; Fiehn, Oliver; Kelly, Karen; Miyamoto, Suzanne

    2015-01-01

    Background Untargeted metabolomics was utilized in case control studies of adenocarcinoma (ADC) lung cancer in order to develop and test metabolite classifiers in serum and plasma as potential biomarkers for diagnosing lung cancer. Methods Serum and plasma were collected and used in two independent case-control studies (ADC1 and ADC2). Controls were frequency matched for gender, age and smoking history. There were 52 ADC cases and 31 controls in ADC1 and 43 ADC cases and 43 controls in ADC2. Metabolomics was conducted using gas chromatography time-of-flight mass spectrometry. Differential analysis was performed on ADC1 and the top candidates (FDR < 0.05) for serum and plasma used to develop individual and multiplex-classifiers that were then tested on an independent set of serum and plasma samples (ADC2). Results Aspartate provided the best accuracy (81.4%) for an individual metabolite classifier in serum whereas pyrophosphate had the best accuracy (77.9%) in plasma when independently tested. Multiplex classifiers of either 2 or 4 serum metabolites had an accuracy of 72.7% when independently tested. For plasma, a multi-metabolite classifier consisting of 8 metabolites gave an accuracy of 77.3% when independently tested. Comparison of overall diagnostic performance between the two blood matrices yielded similar performances. However, serum is most ideal given higher sensitivity for low abundant metabolites. Conclusion This study shows the potential of metabolite-based diagnostic tests for detection of lung adenocarcinoma. Further validation in a larger pool of samples is warranted. Impact These biomarkers could improve early detection and diagnosis of lung cancer. PMID:26282632

  19. Determination of dextromethorphan in human plasma using pipette tip solid-phase extraction and gas chromatography-mass spectrometry.

    PubMed

    Hasegawa, Chika; Kumazawa, Takeshi; Uchigasaki, Seisaku; Lee, Xiao-Pen; Sato, Keizo; Terada, Masaru; Kurosaki, Kunihiko

    2011-10-01

    Dextromethorphan was extracted from human plasma samples (100 μL) using MonoTip C(18) tips, which are packed with C(18)-bonded monolithic silica gel that is attached to the inside of the tip. The samples, which contained dextromethorphan and trimeprazine as an internal standard (IS), were mixed with 200 μL of distilled water and 50 μL of 1 mol/L glycine-sodium hydroxide buffer (pH 10). The mixture was extracted to the C(18) phase of the tip by 20 sequential aspirating/dispensing cycles using a manual micropipettor. The analytes retained on the C(18) phase were then eluted with methanol by five sequential aspirating/dispensing cycles. The eluate was injected directly into a gas chromatograph and detected by a mass spectrometer with selected ion monitoring in positive electron ionization mode. An Equity-5 fused silica capillary column (30 m × 0.32 mm i.d., film thickness 0.5 μm) gave adequate separation of the dextromethorphan, IS, and impurities. The recoveries of dextromethorphan and the IS spiked into plasma were >87.4%. The regression equation for dextromethorphan showed excellent linearity from 2.5 to 320 ng/mL of plasma, and the limit of detection was 1.25 ng/mL of plasma. The intraday and interday coefficients of variation were less than 10.5% and 14.7%, respectively. The accuracy ranged from 91.9% to 107%. The validated method was successfully used to quantify the plasma concentration of dextromethorphan in a human subject after oral administration of the drug. © Springer-Verlag 2011

  20. Fast and sensitive HPLC/UV method for cefazolin quantification in plasma and subcutaneous tissue microdialysate of humans and rodents applied to pharmacokinetic studies in obese individuals.

    PubMed

    Palma, Eduardo Celia; Laureano, João Victor; de Araújo, Bibiana Verlindo; Meinhardt, Nelson Guardiola; Stein, Airton Tetelbom; Dalla Costa, Teresa

    2018-04-14

    Antimicrobial prophylactic dosing of morbidly obese patients may differ from normal weighted individuals owing to alterations in drug tissue distribution. Drug subcutaneous tissue distribution can be investigated by microdialysis patients and animals. The need for cefazolin prophylactic dose adjustment in obese patients remains under discussion. The paper describes the validation of an HPLC-UV method for cefazolin quantification in plasma and microdialysate samples from clinical and pre-clinical studies. A C 18 column with an isocratic mobile phase was used for drug separation, with detection at 272 nm. Total and unbound cefazolin lower limit of quantitation was 5 μg/mL in human plasma, 2 μg/mL in rat plasma, and 0.5 and 0.025 μg/mL in human and rat microdialysate samples, respectively. The maximum intra- and inter-day imprecisions were 10.7 and 8.1%, respectively. The inaccuracy was <9.7%. The limit of quantitation imprecision and inaccuracy were < 15%. Cefazolin stability in the experimental conditions was confirmed. Cefazolin plasma concentrations and subcutaneous tissue penetration were determined by microdialysis in morbidly obese patients (2 g i.v. bolus) and diet-induced obese rats (30 mg/kg i.v. bolus) using the method. This method has the main advantages of easy plasma clean-up and practicability and has proven to be useful in cefazolin clinical and pre-clinical pharmacokinetic investigations. Copyright © 2018 John Wiley & Sons, Ltd.

  1. Circulating Plasma Levels of MicroRNA-21 and MicroRNA-221 Are Potential Diagnostic Markers for Primary Intrahepatic Cholangiocarcinoma

    PubMed Central

    Kemeny, Nancy; Kingham, T. Peter; Allen, Peter J.; D’Angelica, Michael I.; DeMatteo, Ronald P.; Betel, Doron; Klimstra, David; Jarnagin, William R.; Ventura, Andrea

    2016-01-01

    Background MicroRNAs (miRNAs) are potential biomarkers in various malignancies. We aim to characterize miRNA expression in intrahepatic cholangiocarcinoma (ICC) and identify circulating plasma miRNAs with potential diagnostic and prognostic utility. Methods Using deep-sequencing techniques, miRNA expression between tumor samples and non-neoplastic liver parenchyma were compared. Overexpressed miRNAs were measured in plasma from an independent cohort of patients with cholangiocarcinoma using RT-qPCR and compared with that healthy volunteers. The discriminatory ability of the evaluated plasma miRNAs between patients and controls was evaluated with receiving operating characteristic (ROC) curves. Results Small RNAs from 12 ICC and 11 tumor-free liver samples were evaluated. Unsupervised hierarchical clustering using the miRNA expression data showed clear grouping of ICC vs. non-neoplastic liver parenchyma. We identified 134 down-regulated and 128 upregulated miRNAs. Based on overexpression and high fold-change, miR21, miR200b, miR221, and miR34c were measured in plasma from an independent cohort of patients with ICC (n = 25) and healthy controls (n = 7). Significant overexpression of miR-21 and miR-221 was found in plasma from ICC patients. Furthermore, circulating miR-21 demonstrated a high discriminatory ability between patients with ICC and healthy controls (AUC: 0.94). Conclusion Among the differentially expressed miRNAs in ICC, miR-21 and miR-221 are overexpressed and detectable in the circulation. Plasma expression levels of these miRNAs, particularly miR-21, accurately differentiates patients with ICC from healthy controls and could potentially serve as adjuncts in diagnosis. Prospective validation and comparison with other hepatobiliary malignancies is required to establish their potential role as diagnostic and prognostic biomarkers. PMID:27685844

  2. Comparison of Dilution, Filtration, and Microwave Digestion Sample Pretreatments in Elemental Profiling of Wine by ICP-MS.

    PubMed

    Godshaw, Joshua; Hopfer, Helene; Nelson, Jenny; Ebeler, Susan E

    2017-09-25

    Wine elemental composition varies by cultivar, geographic origin, viticultural and enological practices, and is often used for authenticity validation. Elemental analysis of wine by Inductively Coupled Plasma Mass Spectrometry (ICP-MS) is challenging due to the potential for non-spectral interferences and plasma instability arising from organic matrix components. Sample preparation mitigates these interferences, however, conflicting recommendations of best practices in ICP-MS analysis of wine have been reported. This study compared direct dilution, microwave-assisted acid digestion, and two filtration sample pretreatments, acidification prior to filtration and filtration followed by acidification, in elemental profiling of one white and three red table wines by ICP-MS. Of 43 monitored isotopes, 37 varied by sample preparation method, with significantly higher results of 17 isotopes in the microwave-digested samples. Both filtration treatments resulted in lower results for 11 isotopes compared to the other methods. Finally, isotope dilution determination of copper based on natural abundances and the 63 Cu: 65 Cu instrument response ratio agreed with external calibration and confirmed a significant sample preparation effect. Overall, microwave digestion did not compare favorably, and direct dilution was found to provide the best compromise between ease of use and result accuracy and precision, although all preparation strategies were able to differentiate the wines.

  3. Pre-analytical effects of blood sampling and handling in quantitative immunoassays for rheumatoid arthritis.

    PubMed

    Zhao, Xiaoyan; Qureshi, Ferhan; Eastman, P Scott; Manning, William C; Alexander, Claire; Robinson, William H; Hesterberg, Lyndal K

    2012-04-30

    Variability in pre-analytical blood sampling and handling can significantly impact results obtained in quantitative immunoassays. Understanding the impact of these variables is critical for accurate quantification and validation of biomarker measurements. Particularly, in the design and execution of large clinical trials, even small differences in sample processing and handling can have dramatic effects in analytical reliability, results interpretation, trial management and outcome. The effects of two common blood sampling methods (serum vs. plasma) and two widely-used serum handling methods (on the clot with ambient temperature shipping, "traditional", vs. centrifuged with cold chain shipping, "protocol") on protein and autoantibody concentrations were examined. Matched serum and plasma samples were collected from 32 rheumatoid arthritis (RA) patients representing a wide range of disease activity status. Additionally, a set of matched serum samples with two sample handling methods was collected. One tube was processed per manufacturer's instructions and shipped overnight on cold packs (protocol). The matched tube, without prior centrifugation, was simultaneously shipped overnight at ambient temperatures (traditional). Upon delivery, the traditional tube was centrifuged. All samples were subsequently aliquoted and frozen prior to analysis of protein and autoantibody biomarkers. Median correlation between paired serum and plasma across all autoantibody assays was 0.99 (0.98-1.00) with a median % difference of -3.3 (-7.5 to 6.0). In contrast, observed protein biomarker concentrations were significantly affected by sample types, with median correlation of 0.99 (0.33-1.00) and a median % difference of -10 (-55 to 23). When the two serum collection/handling methods were compared, the median correlation between paired samples for autoantibodies was 0.99 (0.91-1.00) with a median difference of 4%. In contrast, significant increases were observed in protein biomarker concentrations among certain biomarkers in samples processed with the 'traditional' method. Autoantibody quantification appears robust to both sample type (plasma vs. serum) and pre-analytical sample collection/handling methods (protocol vs. traditional). In contrast, for non-antibody protein biomarker concentrations, sample type had a significant impact; plasma samples generally exhibit decreased protein biomarker concentrations relative to serum. Similarly, sample handling significantly impacted the variability of protein biomarker concentrations. When biomarker concentrations are combined algorithmically into a single test score such as a multi-biomarker disease activity test for rheumatoid arthritis (MBDA), changes in protein biomarker concentrations may result in a bias of the score. These results illustrate the importance of characterizing pre-analytical methodology, sample type, sample processing and handling procedures for clinical testing in order to ensure test accuracy. Copyright © 2012 Elsevier B.V. All rights reserved.

  4. Dried blood spot analysis of creatinine with LC-MS/MS in addition to immunosuppressants analysis.

    PubMed

    Koster, Remco A; Greijdanus, Ben; Alffenaar, Jan-Willem C; Touw, Daan J

    2015-02-01

    In order to monitor creatinine levels or to adjust the dosage of renally excreted or nephrotoxic drugs, the analysis of creatinine in dried blood spots (DBS) could be a useful addition to DBS analysis. We developed a LC-MS/MS method for the analysis of creatinine in the same DBS extract that was used for the analysis of tacrolimus, sirolimus, everolimus, and cyclosporine A in transplant patients with the use of Whatman FTA DMPK-C cards. The method was validated using three different strategies: a seven-point calibration curve using the intercept of the calibration to correct for the natural presence of creatinine in reference samples, a one-point calibration curve at an extremely high concentration in order to diminish the contribution of the natural presence of creatinine, and the use of creatinine-[(2)H3] with an eight-point calibration curve. The validated range for creatinine was 120 to 480 μmol/L (seven-point calibration curve), 116 to 7000 μmol/L (1-point calibration curve), and 1.00 to 400.0 μmol/L for creatinine-[(2)H3] (eight-point calibration curve). The precision and accuracy results for all three validations showed a maximum CV of 14.0% and a maximum bias of -5.9%. Creatinine in DBS was found stable at ambient temperature and 32 °C for 1 week and at -20 °C for 29 weeks. Good correlations were observed between patient DBS samples and routine enzymatic plasma analysis and showed the capability of the DBS method to be used as an alternative for creatinine plasma measurement.

  5. Clinical Validation of Simultaneous Analysis of Tacrolimus, Cyclosporine A, and Creatinine in Dried Blood Spots in Kidney Transplant Patients.

    PubMed

    Veenhof, Herman; Koster, Remco A; Alffenaar, Jan-Willem C; Berger, Stefan P; Bakker, Stephan J L; Touw, Daan J

    2017-07-01

    Monitoring of creatinine and immunosuppressive drug concentrations, such as tacrolimus (TaC) and cyclosporin A (CsA), is important in the outpatient follow-up of kidney transplant recipients. Monitoring by dried blood spot (DBS) provides patients the opportunity to sample a drop of blood from a fingerprick at home, which can be sent to the laboratory by mail. We performed a clinical validation in which we compared measurements from whole-blood samples obtained by venapuncture with measurements from DBS samples simultaneously obtained by fingerprick. After exclusion of 10 DBS for poor quality, and 2 for other reasons, 199, 104, and 58 samples from a total of 172 patients were available for validation of creatinine, TaC and CsA, respectively. Validation was performed by means of Passing & Bablok regression, and bias was assessed by Bland-Altman analysis. For creatinine, we found y = 0.73x - 1.55 (95% confidence interval [95% CI] slope, 0.71-0.76), giving the conversion formula: (creatinine plasma concentration in μmol/L) = (creatinine concentration in DBS in μmol/L)/0.73, with a nonclinically relevant bias of -2.1 μmol/L (95% CI, -3.7 to -0.5 μmol/L). For TaC, we found y = 1.00x - 0.23 (95% CI slope, 0.91-1.08), with a nonclinically relevant bias of -0.28 μg/L (95% CI, -0.45 to -0.12 μg/L). For CsA, we found y = 0.99x - 1.86 (95% CI slope, 0.91-1.08) and no significant bias. Therefore, for neither TaC nor CsA, a conversion formula is required. DBS sampling for the simultaneous analysis of immunosuppressants and creatinine can replace conventional venous sampling in daily routine.

  6. A rapid and sensitive method for the quantitation of montelukast in sheep plasma using liquid chromatography/tandem mass spectrometry.

    PubMed

    Papp, Robert; Luk, Pauline; Mullett, Wayne M; Kwong, Elizabeth

    2007-10-15

    A rapid LC-MS/MS method was developed and partially validated for the quantitation of montelukast in spiked sheep plasma. A total run time of 1.5 min was achieved using a short monolithic column and employing a rapid gradient. Sample preparation involved protein precipitation with twofold acetonitrile by volume during which a deuterated internal standard (montelukast D-6) was incorporated. The MRM transitions for montelukast and the deuterated internal standard were 586/422 and 592/427, respectively. A linear dynamic range of 0.25-500 ng/mL with a correlation coefficient of 0.9999 was achieved. Precision was below 5% at all levels except at the LOQ (0.36 ng/mL) which demonstrated an overall of R.S.D. of 8%. Post-column infusion experiments were performed with precipitated plasma matrix and showed minimal interference with the peaks of interest.

  7. Determination of moxifloxacin in human plasma, plasma ultrafiltrate, and cerebrospinal fluid by a rapid and simple liquid chromatography- tandem mass spectrometry method.

    PubMed

    Pranger, Arianna D; Alffenaar, Jan-Willem C; Wessels, A Mireille A; Greijdanus, Ben; Uges, Donald R A

    2010-04-01

    Moxifloxacin (MFX) is a useful agent in the treatment of multi-drug-resistant tuberculosis (MDR-TB). At Tuberculosis Centre Beatrixoord, a referral center for tuberculosis in the Netherlands, approximately 36% of the patients have received MFX as treatment. Based on the variability of MFX AUC, the variability of in vitro susceptibility to MFX of M. tuberculosis, and the variability of penetration into sanctuary sites, measuring the concentration of MFX in plasma and cerebrospinal fluid (CSF) could be recommended. Therefore, a rapid and validated liquid chromatography-tandem mass spectrometry (LC-MS-MS) analyzing method with a simple pretreatment procedure was developed for therapeutic drug monitoring of MFX in human plasma and CSF. Because of the potential influence of protein binding on efficacy, we decided to determine both bound and unbound (ultrafiltrate) fraction of MFX. The calibration curves were linear in the therapeutic range of 0.05 to 5.0 mg/L plasma and CSF with CV in the range of -5.4% to 9.3%. MFX ultrafiltrate samples could be determined with the same method setup for analysis of MFX in CSF. The LC-MS-MS method developed in this study is suitable for monitoring MFX in human plasma, plasma ultrafiltrate, and CSF.

  8. Bioanalytical Method for Carbocisteine in Human Plasma by Using LC-MS/MS: A Pharmacokinetic Application.

    PubMed

    Dhanure, Shivanand; Savalia, Atulkumar; More, Pravinkumar; Shirode, Prashant; Kapse, Kailas; Shah, Virag

    2014-01-01

    A simple, sensitive, and selective LC-MS/MS method was developed and validated for the quantification of carbocisteine in human plasma. Rosiglitazone was used as the internal standard and heparin was used as the anticoagulant. The chromatographic separation was performed by using the Waters Symmetry Shield RP 8, 150 × 3.9 mm, 5 μ column at 40°C with a mobile phase consisting of a mixture of methanol and 0.5% formic acid solution in a 40:60 proportion. The flow rate was 500 μl/min along with a 5 μl injection volume. Protein precipitation was used as the extraction method. Mass spectrometric data were detected in positive ion mode. The MRM mode of the ions for carbocisteine was 180.0 > 89.0 and for rosiglitazone it was 238.1 > 135.1. The method was validated in the concentration curve range of 50.000 ng/mL to 6000.000 ng/mL. The retention times of carbocisteine and the internal standard rosiglitazone were approximately 2.20 and 3.01 min, respectively. The overall run time was 4.50 min. This method was found suitable to analyze human plasma samples for the application in pharmacokinetic and BA/BE studies.

  9. Simultaneous determination of multiclass pesticide residues in human plasma using a mini QuEChERS method.

    PubMed

    Srivastava, Anshuman; Rai, Satyajeet; Kumar Sonker, Ashish; Karsauliya, Kajal; Pandey, Chandra Prabha; Singh, Sheelendra Pratap

    2017-06-01

    Blood is one of the most assessable matrices for the determination of pesticide residue exposure in humans. Effective sample preparation/cleanup of biological samples is very important in the development of a sensitive, reproducible, and robust method. In the present study, a simple, cost-effective, and rapid gas chromatography-tandem mass spectrometry method has been developed and validated for simultaneous analysis of 31 multiclass (organophosphates, organochlorines, and synthetic pyrethroids) pesticide residues in human plasma by means of a mini QuEChERS (quick, easy, cheap, effective, rugged, and safe) method. We have adopted a modified version of the QuEChERS method, which is primarily used for pesticide residue analysis in food commodities. The QuEChERS method was optimized by use of different extraction solvents and different amounts and combinations of salts and sorbents (primary-secondary amines and C 18 ) for the dispersive solid-phase extraction step. The results show that a combination of ethyl acetate with 2% acetic acid, magnesium sulfate (0.4 g), and solid-phase extraction for sample cleanup with primary-secondary amines (50 mg) per 1-mL volume of plasma is the most suitable for generating acceptable results with high recoveries for all multiclass pesticides from human plasma. The mean recovery ranged from 74% to 109% for all the analytes. The limit of quantification and limit of detection of the method ranged from 0.12 to 13.53 ng mL -1 and from 0.04 to 4.10 ng mL -1 respectively. The intraday precision and the interday precision of the method were 6% or less and 11% or less respectively. This method would be useful for the analysis of a wide range of pesticides of interest in a small volume of clinical and/or forensic samples to support biomonitoring and toxicological applications. Graphical Abstract Pesticide residues analysis in human plasma using mini QuEChERS method.

  10. Salivary and plasma cortisol and testosterone responses to interval and tempo runs and a bodyweight-only circuit session in endurance-trained men.

    PubMed

    Tanner, Amy Vivien; Nielsen, Birthe Vejby; Allgrove, Judith

    2014-01-01

    The aim of this study was to examine the acute response to plasma and salivary cortisol and testosterone to three training protocols. Ten trained endurance athletes participated in three experimental trials, such as interval training (INT), tempo run (TEMP) and bodyweight-only circuit training (CIR), on separate days. Blood and saliva samples were collected pre- and 0, 15, 30 and 60 min post-exercise. Peak post-exercise salivary cortisol was higher than pre-exercise in all trials (P < 0.01). After INT, salivary cortisol remained elevated above pre-exercise than 60 min post-exercise. Salivary testosterone also increased post-exercise in all trials (P < 0.05). Plasma and salivary cortisol were correlated between individuals (r = 0.81, 0.73-0.88) and within individuals (r = 0.81, 0.73-0.87) (P < 0.01). Plasma and salivary testosterone was also correlated between (r = 0.57, 0.43-0.69) and within individuals (r = 0.60, 0.45-0.72), (P < 0.01). Peak cortisol and testosterone levels occurred simultaneously in plasma and saliva, but timing of post-exercise hormone peaks differed between trials and individuals. Further investigation is required to identify the mechanisms eliciting an increase in hormones in response to CIR. Furthermore, saliva is a valid alternative sampling technique for measurement of cortisol, although the complex, individual and situation dependent nature of the hormone response to acute exercise should be considered.

  11. Simultaneous quantification of 21 water soluble vitamin circulating forms in human plasma by liquid chromatography-mass spectrometry.

    PubMed

    Meisser Redeuil, Karine; Longet, Karin; Bénet, Sylvie; Munari, Caroline; Campos-Giménez, Esther

    2015-11-27

    This manuscript reports a validated analytical approach for the quantification of 21 water soluble vitamins and their main circulating forms in human plasma. Isotope dilution-based sample preparation consisted of protein precipitation using acidic methanol enriched with stable isotope labelled internal standards. Separation was achieved by reversed-phase liquid chromatography and detection performed by tandem mass spectrometry in positive electrospray ionization mode. Instrumental lower limits of detection and quantification reached <0.1-10nM and 0.2-25nM, respectively. Commercially available pooled human plasma was used to build matrix-matched calibration curves ranging 2-500, 5-1250, 20-5000 or 150-37500nM depending on the analyte. The overall performance of the method was considered adequate, with 2.8-20.9% and 5.2-20.0% intra and inter-day precision, respectively and averaged accuracy reaching 91-108%. Recovery experiments were also performed and reached in average 82%. This analytical approach was then applied for the quantification of circulating water soluble vitamins in human plasma single donor samples. The present report provides a sensitive and reliable approach for the quantification of water soluble vitamins and main circulating forms in human plasma. In the future, the application of this analytical approach will give more confidence to provide a comprehensive assessment of water soluble vitamins nutritional status and bioavailability studies in humans. Copyright © 2015 Elsevier B.V. All rights reserved.

  12. Determination of rhynchophylline and hirsutine in rat plasma by UPLC-MS/MS after oral administration of Uncaria rhynchophylla extract.

    PubMed

    Wu, Yu-Tse; Lin, Lie-Chwen; Tsai, Tung-Hu

    2014-03-01

    An ultra-performance liquid chromatography with tandem mass spectrometry (UPLC-MS/MS) method was developed and validated to concurrently determine rhynchophylline and hirsutine in rat plasma. The sample preparation of rat plasma was achieved by alkalization and liquid-liquid extraction. The mass transition of precursor ion → product ion pairs were monitored at m/z 385.2 → 160.0 for rhynchophylline, m/z 369.3 → 144.0 for hirsutine and m/z 414.0 → 220.0 for noscapine (internal standard). This method revealed linear relationships from 2.5 to 50 ng/mL (r(2)  > 0.997) for rhynchophylline and from 2.5 to 50 ng/mL (r(2)  > 0.998) for hirsutine. The limit of quantification values for rhynchophylline and hirsutine in rat plasma were both 2.5 ng/mL. Intra-day and inter-day precisions were within 10.6% and 12.5%, respectively, for rhynchophylline and hirsutine, and the accuracy (bias) was <10%. Liquid-liquid extraction of rat plasma samples resulted in insignificant matrix effect, and the extraction recoveries were >83.6% for rhynchophylline, 73.4% for hirsutine and 90.7% for the internal standard. This method was applied successfully to a pharmacokinetic study of rhynchophylline and hirsutine in rats after oral administration. Copyright © 2013 John Wiley & Sons, Ltd.

  13. Reliability and Validity of Food Frequency Questionnaire and Nutrient Biomarkers in Elders With and Without Mild Cognitive Impairment

    PubMed Central

    Bowman, Gene L.; Shannon, Jackilen; Ho, Emily; Traber, Maret G.; Frei, Balz; Oken, Barry S.; Kaye, Jeffery A.; Quinn, Joseph F.

    2010-01-01

    Introduction There is great interest in nutritional strategies for the prevention of age-related cognitive decline, yet the best methods for nutritional assessment in populations at risk for dementia are still evolving. Our study objective was to test the reliability and validity of two common nutritional assessments (plasma nutrient biomarkers and Food Frequency Questionnaire) in people at risk for dementia. Methods Thirty-eight elders, half with amnestic -Mild Cognitive Impairment and half with intact cognition were recruited. Nutritional assessments were collected together at baseline and again at 1 month. Intraclass and Pearson correlation coefficients quantified reliability and validity. Results Twenty-six nutrients were examined and reliability was very good or better for 77% (20/26, ICC ≥ .75) of the plasma nutrient biomarkers and for 88% of the FFQ estimates. Twelve of the plasma nutrient estimates were as reliable as the commonly measured plasma cholesterol (ICC=.92). FFQ and plasma long-chain fatty acids (docosahexaenoic acid, r =.39, eicosapentaenoic acid, r = .39) and carotenoids (α-carotene, r =.49; lutein + zeaxanthin, r = .48; β-carotene, r = .43; β-cryptoxanthin, r = .41) were correlated, but no other FFQ estimates correlated with respective nutrient biomarkers. Correlations between FFQ and plasma fatty acids and carotenoids were significantly stronger after removing subjects with MCI. Conclusion The reliability and validity of plasma and FFQ nutrient estimates vary according to the nutrient of interest. Memory deficit attenuates FFQ estimate validity and inflates FFQ estimate reliability. Many plasma nutrient biomarkers have very good reliability over 1-month regardless of memory state. This method can circumvent sources of error seen in other less direct methods of nutritional assessment. PMID:20856100

  14. A solid phase extraction-liquid chromatographic-tandem mass spectrometry method for determination of concentrations of GDC-0941, a small molecule class I phosphatidylinositide 3-kinase inhibitor, to support clinical development.

    PubMed

    Ding, X; Morrison, G; Dean, B; Hop, C E C A; Tobler, L; Percey, S; Meng, M; Reuschel, S; West, D A; Holden, S; Ware, J A

    2012-03-05

    A solid phase extraction (SPE) liquid chromatographic-tandem mass spectrometry (LC-MS/MS) method for the determination of GDC-0941 concentrations in human plasma has been developed and validated to support clinical development. An Oasis MCX 10mg 96-well SPE plate was used to extract plasma samples (50 μL) and the resulting extracts were analyzed using reverse-phase chromatography and mass spectrometer coupled with a turbo-ionspray interface. The method was validated over the calibration curve range 0.500-500 ng/mL with linear regression and 1/x(2) weighting. Within-run relative standard deviation (%RSD) ranged from 1.5 to 11.5%, while the between-run %RSD varied from 0.0 to 4.4%. The accuracy ranged from 96.0% to 110.0% of nominal for within-run and 98.0% to 108.0% of nominal for between-run at all concentrations including the LLOQ quality control at 0.500 ng/mL. Extraction recovery of GDC-0941 was between 79.0% and 86.2%. Stability of GDC-0941 was established in human plasma for 602 days at -70 °C and 598 days at -20°C, respectively, and established in reconstituted sample extracts for 167 h when stored at room temperature. Internal standard normalized matrix factor was 1.1, demonstrating that the use of the stable-labeled internal standard GDC-0941-d(8) effectively compensated observed matrix effect and resulting in no adverse impact on the quality of the data produced. This assay was used for the determination of GDC-0941 human plasma concentrations over a sufficient time period to determine pharmacokinetic parameters at relevant clinical doses. Copyright © 2011 Elsevier B.V. All rights reserved.

  15. Parallel achiral-chiral determination of oxybutynin, N-desethyl oxybutynin and their enantiomers in human plasma by LC-MS/MS to support a bioequivalence trial.

    PubMed

    Sharma, Primal; Patel, Daxesh P; Sanyal, Mallika; Guttikar, Swati; Shrivastav, Pranav S

    2014-01-01

    A parallel achiral and chiral determination of oxybutynin, its pharmacologically active metabolite N-desethyl oxybutynin and their enantiomers in human plasma is described using LC-MS/MS. Both the methods were developed and validated using deuterated analogues as internal standards. Achiral analysis of racemic oxybutynin and N-desethyl oxybutynin was carried out on Phenomenex Gemini C18 (150mm×4.6mm, 5μm) column under isocratic conditions using acetonitrile-5.0mM ammonium acetate, pH 4.0 (90:10, v/v) as the mobile phase. Separation of (S)- and (R)-enantiomers of the analytes was performed on Phenomenex Lux Amylose-2 (150mm×4.6mm, 3μm) chiral column using a mixture of solvent A [acetonitrile:10mM ammonium bicarbonate, 80:20 (v/v)] and solvent B [2-propanol:methanol, 50:50 (v/v)] in 20:80 (v/v) ratio as the mobile phase. Plasma samples were prepared by liquid-liquid extraction with ethyl acetate-diethyl ether-n-hexane solvent mixture. A linear range was established from 0.025 to 10.0ng/mL and 0.25 to 100ng/mL for the enantiomers of oxybutynin and N-desethyl oxybutynin respectively. The extraction recovery varied from 96.0 to 105.1%, while the IS-normalized matrix factors ranged from 0.96 to 1.07 for all the enantiomers. The validated method was applied for a pilot bioequivalence study with 5mg oxybutynin tablet formulation in 8 healthy subjects. The pharmacokinetic profiles showed that the plasma concentration of (R)-oxybutynin was lower than that of (S)-oxybutynin, while a reverse trend was observed for the enantiomers of N-desethyl oxybutynin. The reproducibility in the measurement of study data was demonstrated by reanalysis of 20 incurred samples. Copyright © 2013 Elsevier B.V. All rights reserved.

  16. Liquid-liquid extraction of strongly protein bound BMS-299897 from human plasma and cerebrospinal fluid, followed by high-performance liquid chromatography/tandem mass spectrometry.

    PubMed

    Xue, Y J; Pursley, Janice; Arnold, Mark

    2007-04-11

    BMS-299897 is a gamma-secretase inhibitor that is being developed for the treatment of Alzheimer's disease. Liquid-liquid extraction (LLE), chromatographic/tandem mass spectrometry (LC/MS/MS) methods have been developed and validated for the quantitation of BMS-299897 in human plasma and cerebrospinal fluid (CSF). Both methods utilized (13)C6-BMS-299897, the stable label isotope analog, as the internal standard. For the human plasma extraction method, two incubation steps were required after the addition of 5 mM ammonium acetate and the internal standard in acetonitrile to release the analyte bound to proteins prior to LLE with toluene. For the human CSF extraction method, after the addition of 0.5 N HCl and the internal standard, CSF samples were extracted with toluene and no incubation was required. The organic layers obtained from both extraction methods were removed and evaporated to dryness. The residues were reconstituted and injected into the LC/MS/MS system. Chromatographic separation was achieved isocratically on a MetaChem C18 Hypersil BDS column (2.0 mm x 50 mm, 3 microm). The mobile phase contained 10 mM ammonium acetate pH 5 and acetonitrile. Detection was by negative ion electrospray tandem mass spectrometry. The standard curves ranged from 1 to 1000 ng/ml for human plasma and 0.25-100 ng/ml for human CSF. Both standard curves were fitted to a 1/x weighted quadratic regression model. For both methods, the intra-assay precision was within 8.2% CV, the inter-assay precision was within 5.4% CV, and assay accuracy was within +/-7.4% of the nominal values. The validation and sample analysis results demonstrated that both methods had acceptable precision and accuracy across the calibration ranges.

  17. High Performance Liquid Chromatographic Assay for the Simultaneous Determination of Posaconazole and Vincristine in Rat Plasma

    PubMed Central

    Khalil, Hadeel A.; El-Yazbi, Ahmed F.; Belal, Tarek S.; Hamdy, Dalia A.

    2015-01-01

    Purpose. Developing a validated HPLC-DAD method for simultaneous determination of posaconazole (PSZ) and vincristine (VCR) in rat plasma. Methods. PSZ, VCR, and itraconazole (ITZ) were extracted from 200 μL plasma using diethyl ether in the presence of 0.1 M sodium hydroxide solution. The organic layer was evaporated in vacuo and dried residue was reconstituted and injected through HC-C18 (4.6 × 250 mm, 5 μm) column. In the mobile phase, acetonitrile and 0.015 M potassium dihydrogen orthophosphate (30 : 70 to 80 : 20, linear gradient over 7 minutes) pumped at 1.5 mL/min. VCR and PSZ were measured at 220 and 262 nm, respectively. Two Sprague Dawley rats were orally dosed PSZ followed by iv dosing of VCR and serial blood sampling was performed. Results. VCR, PSZ, and ITZ were successfully separated within 11 min. Calibration curves were linear over the range of 50–5000 ng/mL for both drugs. The CV% and % error of the mean were ≤18% and limit of quantitation was 50 ng/mL for both drugs. Rat plasma concentrations of PSZ and VCR were simultaneously measured up to 72 h and their calculated pharmacokinetics parameters were comparable to the literature. Conclusion. The assay was validated as per ICH guidelines and is appropriate for pharmacokinetics drug-drug interaction studies. PMID:27034675

  18. Simultaneous determination of acetylpuerarin and puerarin in rat plasma by liquid chromatography-tandem mass spectrometry: Application to a pharmacokinetic study following intravenous and oral administration.

    PubMed

    Sun, Deqing; Xue, Aiying; Wu, Jing; Zhang, Bin; Yu, Jinlong; Li, Qiang; Sun, Chao

    2015-07-15

    A rapid and sensitive liquid chromatography-tandem mass spectrometric (LC-MS/MS) method was developed and validated for the simultaneous determination of acetylpuerarin (AP) and its major metabolite puerarin (PUE) in rat plasma using genistein as the internal standard (IS). Plasma samples were pretreated by protein precipitation with a mixture of methanol and acetonitrile. Chromatographic separation was performed on a CAPCELL PAK C18 MGШ column with a mixture of 0.1% formic acid in water and methanol (35:65, v/v) as the mobile phase. The analytes were detected using a tandem mass spectrometer in the positive ionization and multiple-reaction monitoring mode. The ion transition of m/z 669.4→627.3, 417.5→297.6 and 271.3→153.0 was utilized to quantify AP, PUE and the IS, respectively. The calibration curves showed good linearity over the plasma concentration range of 1-2000ng/mL for AP and 2.5-5000ng/mL for PUE. The intra- and inter-day precisions (RSD %) for each analyte were less than 6.91%, and the accuracies ranged from -2.17% to 2.93%. The validated LC-MS/MS method was further successfully applied to a pharmacokinetic study of AP and PUE in rats following intravenous and oral administration. Copyright © 2015 Elsevier B.V. All rights reserved.

  19. HPLC with fluorescence detection assay of perampanel, a novel AMPA receptor antagonist, in human plasma for clinical pharmacokinetic studies.

    PubMed

    Mano, Yuji; Takenaka, Osamu; Kusano, Kazutomi

    2015-10-01

    Perampanel (Fycompa®), a novel α-amino-3-hydroxy-5-methyl-4-isoxazolepropionic acid (AMPA) receptor antagonist, is registered for the adjunctive treatment of patients (aged ≥12 years) with refractory partial-onset seizures. To support therapeutic drug monitoring, a simple high-performance liquid chromatography (HPLC) assay with fluorescence detection was developed to determine perampanel concentrations in human plasma and validated to support clinical trials. Human plasma samples (1.0 mL) were processed by liquid extraction using diethyl ether, followed by chromatographic separation on a YMC Pack Pro C18 column (150 × 4.6 mm i.d., 5 µm) with isocratic elution of acetonitrile-water-acetic acid-sodium acetate (840:560:3:1.8, v/v/v/w) at a flow rate of 1.0 mL/min. Column eluent was monitored at excitation and emission wavelengths of 290 and 430 nm, respectively. The assay was linear (range 1.0-500 ng/mL) and this could be extended to 25 µg/mL by 50-fold dilution integrity. No endogenous peaks were detected in the elution of analytes in drug-free blank human plasma from six individuals and no interference was observed with co-medications tested. Intra- and inter-batch reproducibility studies demonstrated accuracy and precision within the acceptance criteria of bioanalytical guidelines. Validation data demonstrated that our assay is simple, selective, reproducible and suitable for therapeutic drug monitoring of perampanel. Copyright © 2015 John Wiley & Sons, Ltd.

  20. A novel HPLC-MS/MS method for the simultaneous determination of astemizole and its major metabolite in dog or monkey plasma and application to pharmacokinetics.

    PubMed

    Back, Hyun-moon; Lee, Jong-Hwa; Chae, Jung-woo; Song, Byungjeong; Seo, Joung-Wook; Yun, Hwi-yeol; Kwon, Kwang-il

    2015-10-10

    Astemizole (AST), a second-generation antihistamine, is metabolized to desmethyl astemizole (DEA), and although it has been removed from the market for inducing QT interval prolongation, it has reemerged as a potential anticancer and antimalarial agent. This report describes a novel high-performance liquid chromatography-tandem mass spectrometry (HPLC-MS/MS) method for simultaneously determining the concentrations of AST and DEA in beagle dog and cynomolgus monkey plasma with simple preparation method and short retention time. Prior to HPLC analyses, the plasma samples were extracted with simple liquid-liquid extraction method. The isocratic mobile phase was 0.025% trifluoroacetic acid (TFA dissolved in acetonitrile) and 20 mM ammonium acetate (94:6) at a flow rate of 0.25 mL/min and diphenhydramine used as internal standard. In MS/MS analyses, precursor ions of the analytes were optimized as protonated molecular ions: [M+H](+). The lower limit of quantification of astemizole was 2.5 ng/mL in both species and desmethyl astemizole were 7.5 ng/mL and 10 ng/mL in dog and monkey plasma, respectively. The accuracy, precision, and stability of the method were in accordance with FDA guidelines for the validation of bioanalytical methods. Finally this validated method was successfully applied to a pharmacokinetic study in dogs and monkeys after oral administration of 10 mg/kg AST. Copyright © 2015 Elsevier B.V. All rights reserved.

Top