Sample records for validated sample collection

  1. Validation of Statistical Sampling Algorithms in Visual Sample Plan (VSP): Summary Report

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Nuffer, Lisa L; Sego, Landon H.; Wilson, John E.

    2009-02-18

    The U.S. Department of Homeland Security, Office of Technology Development (OTD) contracted with a set of U.S. Department of Energy national laboratories, including the Pacific Northwest National Laboratory (PNNL), to write a Remediation Guidance for Major Airports After a Chemical Attack. The report identifies key activities and issues that should be considered by a typical major airport following an incident involving release of a toxic chemical agent. Four experimental tasks were identified that would require further research in order to supplement the Remediation Guidance. One of the tasks, Task 4, OTD Chemical Remediation Statistical Sampling Design Validation, dealt with statisticalmore » sampling algorithm validation. This report documents the results of the sampling design validation conducted for Task 4. In 2005, the Government Accountability Office (GAO) performed a review of the past U.S. responses to Anthrax terrorist cases. Part of the motivation for this PNNL report was a major GAO finding that there was a lack of validated sampling strategies in the U.S. response to Anthrax cases. The report (GAO 2005) recommended that probability-based methods be used for sampling design in order to address confidence in the results, particularly when all sample results showed no remaining contamination. The GAO also expressed a desire that the methods be validated, which is the main purpose of this PNNL report. The objective of this study was to validate probability-based statistical sampling designs and the algorithms pertinent to within-building sampling that allow the user to prescribe or evaluate confidence levels of conclusions based on data collected as guided by the statistical sampling designs. Specifically, the designs found in the Visual Sample Plan (VSP) software were evaluated. VSP was used to calculate the number of samples and the sample location for a variety of sampling plans applied to an actual release site. Most of the sampling designs

  2. Validating a biometric authentication system: sample size requirements.

    PubMed

    Dass, Sarat C; Zhu, Yongfang; Jain, Anil K

    2006-12-01

    Authentication systems based on biometric features (e.g., fingerprint impressions, iris scans, human face images, etc.) are increasingly gaining widespread use and popularity. Often, vendors and owners of these commercial biometric systems claim impressive performance that is estimated based on some proprietary data. In such situations, there is a need to independently validate the claimed performance levels. System performance is typically evaluated by collecting biometric templates from n different subjects, and for convenience, acquiring multiple instances of the biometric for each of the n subjects. Very little work has been done in 1) constructing confidence regions based on the ROC curve for validating the claimed performance levels and 2) determining the required number of biometric samples needed to establish confidence regions of prespecified width for the ROC curve. To simplify the analysis that address these two problems, several previous studies have assumed that multiple acquisitions of the biometric entity are statistically independent. This assumption is too restrictive and is generally not valid. We have developed a validation technique based on multivariate copula models for correlated biometric acquisitions. Based on the same model, we also determine the minimum number of samples required to achieve confidence bands of desired width for the ROC curve. We illustrate the estimation of the confidence bands as well as the required number of biometric samples using a fingerprint matching system that is applied on samples collected from a small population.

  3. Impact of sample collection participation on the validity of estimated measures of association in the National Birth Defects Prevention Study when assessing gene-environment interactions.

    PubMed

    Jenkins, Mary M; Reefhuis, Jennita; Herring, Amy H; Honein, Margaret A

    2017-12-01

    To better understand the impact that nonresponse for specimen collection has on the validity of estimates of association, we examined associations between self-reported maternal periconceptional smoking, folic acid use, or pregestational diabetes mellitus and six birth defects among families who did and did not submit buccal cell samples for DNA following a telephone interview as part of the National Birth Defects Prevention Study (NBDPS). Analyses included control families with live born infants who had no birth defects (N = 9,465), families of infants with anorectal atresia or stenosis (N = 873), limb reduction defects (N = 1,037), gastroschisis (N = 1,090), neural tube defects (N = 1,764), orofacial clefts (N = 3,836), or septal heart defects (N = 4,157). Estimated dates of delivery were between 1997 and 2009. For each exposure and birth defect, odds ratios and 95% confidence intervals were calculated using logistic regression stratified by race-ethnicity and sample collection status. Tests for interaction were applied to identify potential differences between estimated measures of association based on sample collection status. Significant differences in estimated measures of association were observed in only four of 48 analyses with sufficient sample sizes. Despite lower than desired participation rates in buccal cell sample collection, this validation provides some reassurance that the estimates obtained for sample collectors and noncollectors are comparable. These findings support the validity of observed associations in gene-environment interaction studies for the selected exposures and birth defects among NBDPS participants who submitted DNA samples. Published 2017. This article is a U.S. Government work and is in the public domain in the USA.

  4. The UK Biobank sample handling and storage validation studies.

    PubMed

    Peakman, Tim C; Elliott, Paul

    2008-04-01

    and aims UK Biobank is a large prospective study in the United Kingdom to investigate the role of genetic factors, environmental exposures and lifestyle in the causes of major diseases of late and middle age. It involves the collection of blood and urine from 500 000 individuals aged between 40 and 69 years. How the samples are collected, processed and stored will have a major impact on the future scientific usefulness of the UK Biobank resource. A series of validation studies was recommended to test the robustness of the draft sample handling and storage protocol. Samples of blood and urine were collected from 40 healthy volunteers and either processed immediately according to the protocol or maintained at specified temperatures (4 degrees C for all tubes with the exception of vacutainers containing acid citrate dextrose that were maintained at 18 degrees C) for 12, 24 or 36 h prior to processing. A further sample was maintained for 24 h at 4 degrees C, processed and the aliquots frozen at -80 degrees C for 20 days and then thawed under controlled conditions. The stability of the samples was compared for the different times in a wide variety of assays. The samples maintained at 4 degrees C were stable for at least 24 h after collection for a wide range of assays. Small but significant changes were observed in metabonomic studies in samples maintained at 4 degrees C for 36 h. There was no degradation of the samples for a range of biochemical assays after short-term freezing and thawing under controlled conditions. Whole blood maintained at 18 degrees C for 24 h in vacutainers containing acid citrate dextrose is suitable for viral immortalization techniques. The validation studies reported in this supplement provide justification for the sample handling and storage procedures adopted in the UK Biobank project.

  5. Molecular epidemiology biomarkers-Sample collection and processing considerations

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Holland, Nina T.; Pfleger, Laura; Berger, Eileen

    2005-08-07

    Biomarker studies require processing and storage of numerous biological samples with the goals of obtaining a large amount of information and minimizing future research costs. An efficient study design includes provisions for processing of the original samples, such as cryopreservation, DNA isolation, and preparation of specimens for exposure assessment. Use of standard, two-dimensional and nanobarcodes and customized electronic databases assure efficient management of large sample collections and tracking results of data analyses. Standard operating procedures and quality control plans help to protect sample quality and to assure validity of the biomarker data. Specific state, federal and international regulations are inmore » place regarding research with human samples, governing areas including custody, safety of handling, and transport of human samples. Appropriate informed consent must be obtained from the study subjects prior to sample collection and confidentiality of results maintained. Finally, examples of three biorepositories of different scale (European Cancer Study, National Cancer Institute and School of Public Health Biorepository, University of California, Berkeley) are used to illustrate challenges faced by investigators and the ways to overcome them. New software and biorepository technologies are being developed by many companies that will help to bring biological banking to a new level required by molecular epidemiology of the 21st century.« less

  6. Validation of Marek's disease diagnosis and monitoring of Marek's disease vaccines from samples collected in FTA cards.

    PubMed

    Cortes, Aneg L; Montiel, Enrique R; Gimeno, Isabel M

    2009-12-01

    The use of Flinders Technology Associates (FTA) filter cards to quantify Marek's disease virus (MDV) DNA for the diagnosis of Marek's disease (MD) and to monitor MD vaccines was evaluated. Samples of blood (43), solid tumors (14), and feather pulp (FP; 36) collected fresh and in FTA cards were analyzed. MDV DNA load was quantified by real-time PCR. Threshold cycle (Ct) ratios were calculated for each sample by dividing the Ct value of the internal control gene (glyceraldehyde-3-phosphate dehydrogenase) by the Ct value of the MDV gene. Statistically significant correlation (P < 0.05) within Ct ratios was detected between samples collected fresh and in FTA cards by using Pearson's correlation test. Load of serotype 1 MDV DNA was quantified in 24 FP, 14 solid tumor, and 43 blood samples. There was a statistically significant correlation between FP (r = 0.95), solid tumor (r = 0.94), and blood (r = 0.9) samples collected fresh and in FTA cards. Load of serotype 2 MDV DNA was quantified in 17 FP samples, and the correlation between samples collected fresh and in FTA cards was also statistically significant (Pearson's coefficient, r = 0.96); load of serotype 3 MDV DNA was quantified in 36 FP samples, and correlation between samples taken fresh and in FTA cards was also statistically significant (r = 0.84). MDV DNA samples extracted 3 days (t0) and 8 months after collection (t1) were used to evaluate the stability of MDV DNA in archived samples collected in FTA cards. A statistically significant correlation was found for serotype 1 (r = 0.96), serotype 2 (r = 1), and serotype 3 (r = 0.9). The results show that FTA cards are an excellent media to collect, transport, and archive samples for MD diagnosis and to monitor MD vaccines. In addition, FTA cards are widely available, inexpensive, and adequate for the shipment of samples nationally and internationally.

  7. Validation and Clinical Evaluation of a Novel Method To Measure Miltefosine in Leishmaniasis Patients Using Dried Blood Spot Sample Collection

    PubMed Central

    Rosing, H.; Hillebrand, M. J. X.; Blesson, S.; Mengesha, B.; Diro, E.; Hailu, A.; Schellens, J. H. M.; Beijnen, J. H.

    2016-01-01

    To facilitate future pharmacokinetic studies of combination treatments against leishmaniasis in remote regions in which the disease is endemic, a simple cheap sampling method is required for miltefosine quantification. The aims of this study were to validate a liquid chromatography-tandem mass spectrometry method to quantify miltefosine in dried blood spot (DBS) samples and to validate its use with Ethiopian patients with visceral leishmaniasis (VL). Since hematocrit (Ht) levels are typically severely decreased in VL patients, returning to normal during treatment, the method was evaluated over a range of clinically relevant Ht values. Miltefosine was extracted from DBS samples using a simple method of pretreatment with methanol, resulting in >97% recovery. The method was validated over a calibration range of 10 to 2,000 ng/ml, and accuracy and precision were within ±11.2% and ≤7.0% (≤19.1% at the lower limit of quantification), respectively. The method was accurate and precise for blood spot volumes between 10 and 30 μl and for Ht levels of 20 to 35%, although a linear effect of Ht levels on miltefosine quantification was observed in the bioanalytical validation. DBS samples were stable for at least 162 days at 37°C. Clinical validation of the method using paired DBS and plasma samples from 16 VL patients showed a median observed DBS/plasma miltefosine concentration ratio of 0.99, with good correlation (Pearson's r = 0.946). Correcting for patient-specific Ht levels did not further improve the concordance between the sampling methods. This successfully validated method to quantify miltefosine in DBS samples was demonstrated to be a valid and practical alternative to venous blood sampling that can be applied in future miltefosine pharmacokinetic studies with leishmaniasis patients, without Ht correction. PMID:26787691

  8. Validation sampling can reduce bias in healthcare database studies: an illustration using influenza vaccination effectiveness

    PubMed Central

    Nelson, Jennifer C.; Marsh, Tracey; Lumley, Thomas; Larson, Eric B.; Jackson, Lisa A.; Jackson, Michael

    2014-01-01

    Objective Estimates of treatment effectiveness in epidemiologic studies using large observational health care databases may be biased due to inaccurate or incomplete information on important confounders. Study methods that collect and incorporate more comprehensive confounder data on a validation cohort may reduce confounding bias. Study Design and Setting We applied two such methods, imputation and reweighting, to Group Health administrative data (full sample) supplemented by more detailed confounder data from the Adult Changes in Thought study (validation sample). We used influenza vaccination effectiveness (with an unexposed comparator group) as an example and evaluated each method’s ability to reduce bias using the control time period prior to influenza circulation. Results Both methods reduced, but did not completely eliminate, the bias compared with traditional effectiveness estimates that do not utilize the validation sample confounders. Conclusion Although these results support the use of validation sampling methods to improve the accuracy of comparative effectiveness findings from healthcare database studies, they also illustrate that the success of such methods depends on many factors, including the ability to measure important confounders in a representative and large enough validation sample, the comparability of the full sample and validation sample, and the accuracy with which data can be imputed or reweighted using the additional validation sample information. PMID:23849144

  9. Validation Relaxation: A Quality Assurance Strategy for Electronic Data Collection

    PubMed Central

    Gordon, Nicholas; Griffiths, Thomas; Kraemer, John D; Siedner, Mark J

    2017-01-01

    Background The use of mobile devices for data collection in developing world settings is becoming increasingly common and may offer advantages in data collection quality and efficiency relative to paper-based methods. However, mobile data collection systems can hamper many standard quality assurance techniques due to the lack of a hardcopy backup of data. Consequently, mobile health data collection platforms have the potential to generate datasets that appear valid, but are susceptible to unidentified database design flaws, areas of miscomprehension by enumerators, and data recording errors. Objective We describe the design and evaluation of a strategy for estimating data error rates and assessing enumerator performance during electronic data collection, which we term “validation relaxation.” Validation relaxation involves the intentional omission of data validation features for select questions to allow for data recording errors to be committed, detected, and monitored. Methods We analyzed data collected during a cluster sample population survey in rural Liberia using an electronic data collection system (Open Data Kit). We first developed a classification scheme for types of detectable errors and validation alterations required to detect them. We then implemented the following validation relaxation techniques to enable data error conduct and detection: intentional redundancy, removal of “required” constraint, and illogical response combinations. This allowed for up to 11 identifiable errors to be made per survey. The error rate was defined as the total number of errors committed divided by the number of potential errors. We summarized crude error rates and estimated changes in error rates over time for both individuals and the entire program using logistic regression. Results The aggregate error rate was 1.60% (125/7817). Error rates did not differ significantly between enumerators (P=.51), but decreased for the cohort with increasing days of application

  10. Validation Relaxation: A Quality Assurance Strategy for Electronic Data Collection.

    PubMed

    Kenny, Avi; Gordon, Nicholas; Griffiths, Thomas; Kraemer, John D; Siedner, Mark J

    2017-08-18

    The use of mobile devices for data collection in developing world settings is becoming increasingly common and may offer advantages in data collection quality and efficiency relative to paper-based methods. However, mobile data collection systems can hamper many standard quality assurance techniques due to the lack of a hardcopy backup of data. Consequently, mobile health data collection platforms have the potential to generate datasets that appear valid, but are susceptible to unidentified database design flaws, areas of miscomprehension by enumerators, and data recording errors. We describe the design and evaluation of a strategy for estimating data error rates and assessing enumerator performance during electronic data collection, which we term "validation relaxation." Validation relaxation involves the intentional omission of data validation features for select questions to allow for data recording errors to be committed, detected, and monitored. We analyzed data collected during a cluster sample population survey in rural Liberia using an electronic data collection system (Open Data Kit). We first developed a classification scheme for types of detectable errors and validation alterations required to detect them. We then implemented the following validation relaxation techniques to enable data error conduct and detection: intentional redundancy, removal of "required" constraint, and illogical response combinations. This allowed for up to 11 identifiable errors to be made per survey. The error rate was defined as the total number of errors committed divided by the number of potential errors. We summarized crude error rates and estimated changes in error rates over time for both individuals and the entire program using logistic regression. The aggregate error rate was 1.60% (125/7817). Error rates did not differ significantly between enumerators (P=.51), but decreased for the cohort with increasing days of application use, from 2.3% at survey start (95% CI 1

  11. Sample Collection Procedures and Strategies

    EPA Pesticide Factsheets

    Individuals responsible for collecting environmental and building material samples following a contamination incident, can use these procedures to plan for and/or collect samples for analysis using the analytical methods listed in EPA's SAM

  12. 40 CFR 761.392 - Preparing validation study samples.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 40 Protection of Environment 30 2010-07-01 2010-07-01 false Preparing validation study samples..., AND USE PROHIBITIONS Comparison Study for Validating a New Performance-Based Decontamination Solvent Under § 761.79(d)(4) § 761.392 Preparing validation study samples. (a)(1) To validate a procedure to...

  13. 40 CFR 761.392 - Preparing validation study samples.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... 40 Protection of Environment 31 2011-07-01 2011-07-01 false Preparing validation study samples..., AND USE PROHIBITIONS Comparison Study for Validating a New Performance-Based Decontamination Solvent Under § 761.79(d)(4) § 761.392 Preparing validation study samples. (a)(1) To validate a procedure to...

  14. Validation sampling can reduce bias in health care database studies: an illustration using influenza vaccination effectiveness.

    PubMed

    Nelson, Jennifer Clark; Marsh, Tracey; Lumley, Thomas; Larson, Eric B; Jackson, Lisa A; Jackson, Michael L

    2013-08-01

    Estimates of treatment effectiveness in epidemiologic studies using large observational health care databases may be biased owing to inaccurate or incomplete information on important confounders. Study methods that collect and incorporate more comprehensive confounder data on a validation cohort may reduce confounding bias. We applied two such methods, namely imputation and reweighting, to Group Health administrative data (full sample) supplemented by more detailed confounder data from the Adult Changes in Thought study (validation sample). We used influenza vaccination effectiveness (with an unexposed comparator group) as an example and evaluated each method's ability to reduce bias using the control time period before influenza circulation. Both methods reduced, but did not completely eliminate, the bias compared with traditional effectiveness estimates that do not use the validation sample confounders. Although these results support the use of validation sampling methods to improve the accuracy of comparative effectiveness findings from health care database studies, they also illustrate that the success of such methods depends on many factors, including the ability to measure important confounders in a representative and large enough validation sample, the comparability of the full sample and validation sample, and the accuracy with which the data can be imputed or reweighted using the additional validation sample information. Copyright © 2013 Elsevier Inc. All rights reserved.

  15. Validating Analytical Protocols to Determine Selected Pesticides and PCBs Using Routine Samples.

    PubMed

    Pindado Jiménez, Oscar; García Alonso, Susana; Pérez Pastor, Rosa María

    2017-01-01

    This study aims at providing recommendations concerning the validation of analytical protocols by using routine samples. It is intended to provide a case-study on how to validate the analytical methods in different environmental matrices. In order to analyze the selected compounds (pesticides and polychlorinated biphenyls) in two different environmental matrices, the current work has performed and validated two analytical procedures by GC-MS. A description is given of the validation of the two protocols by the analysis of more than 30 samples of water and sediments collected along nine months. The present work also scopes the uncertainty associated with both analytical protocols. In detail, uncertainty of water sample was performed through a conventional approach. However, for the sediments matrices, the estimation of proportional/constant bias is also included due to its inhomogeneity. Results for the sediment matrix are reliable, showing a range 25-35% of analytical variability associated with intermediate conditions. The analytical methodology for the water matrix determines the selected compounds with acceptable recoveries and the combined uncertainty ranges between 20 and 30%. Analyzing routine samples is rarely applied to assess trueness of novel analytical methods and up to now this methodology was not focused on organochlorine compounds in environmental matrices.

  16. A methodology for collecting valid software engineering data

    NASA Technical Reports Server (NTRS)

    Basili, Victor R.; Weiss, David M.

    1983-01-01

    An effective data collection method for evaluating software development methodologies and for studying the software development process is described. The method uses goal-directed data collection to evaluate methodologies with respect to the claims made for them. Such claims are used as a basis for defining the goals of the data collection, establishing a list of questions of interest to be answered by data analysis, defining a set of data categorization schemes, and designing a data collection form. The data to be collected are based on the changes made to the software during development, and are obtained when the changes are made. To insure accuracy of the data, validation is performed concurrently with software development and data collection. Validation is based on interviews with those people supplying the data. Results from using the methodology show that data validation is a necessary part of change data collection. Without it, as much as 50% of the data may be erroneous. Feasibility of the data collection methodology was demonstrated by applying it to five different projects in two different environments. The application showed that the methodology was both feasible and useful.

  17. Validation of a Sampling Method to Collect Exposure Data for Central-Line-Associated Bloodstream Infections.

    PubMed

    Hammami, Naïma; Mertens, Karl; Overholser, Rosanna; Goetghebeur, Els; Catry, Boudewijn; Lambert, Marie-Laurence

    2016-05-01

    Surveillance of central-line-associated bloodstream infections requires the labor-intensive counting of central-line days (CLDs). This workload could be reduced by sampling. Our objective was to evaluate the accuracy of various sampling strategies in the estimation of CLDs in intensive care units (ICUs) and to establish a set of rules to identify optimal sampling strategies depending on ICU characteristics. Analyses of existing data collected according to the European protocol for patient-based surveillance of ICU-acquired infections in Belgium between 2004 and 2012. CLD data were reported by 56 ICUs in 39 hospitals during 364 trimesters. We compared estimated CLD data obtained from weekly and monthly sampling schemes with the observed exhaustive CLD data over the trimester by assessing the CLD percentage error (ie, observed CLDs - estimated CLDs/observed CLDs). We identified predictors of improved accuracy using linear mixed models. When sampling once per week or 3 times per month, 80% of ICU trimesters had a CLD percentage error within 10%. When sampling twice per week, this was >90% of ICU trimesters. Sampling on Tuesdays provided the best estimations. In the linear mixed model, the observed CLD count was the best predictor for a smaller percentage error. The following sampling strategies provided an estimate within 10% of the actual CLD for 97% of the ICU trimesters with 90% confidence: 3 times per month in an ICU with >650 CLDs per trimester or each Tuesday in an ICU with >480 CLDs per trimester. Sampling of CLDs provides an acceptable alternative to daily collection of CLD data.

  18. Sample Collection Information Document for Chemical & ...

    EPA Pesticide Factsheets

    Report This Sample Collection Information Document (SCID) provides general information for use by EPA and its contractors when collecting samples during environmental remediation following a contamination incident. The document is intended to be used with SAM, and to provide information needed for collection of samples to be analyzed using the specific methods and procedures listed in SAM 2012 (EPA/600/R-12/555).

  19. Feasibility of using subject-collected dust samples in epidemiologic and clinical studies of indoor allergens.

    PubMed

    Arbes, Samuel J; Sever, Michelle; Vaughn, Ben; Mehta, Jigna; Lynch, Jeffrey T; Mitchell, Herman; Hoppin, Jane A; Spencer, Harvey L; Sandler, Dale P; Zeldin, Darryl C

    2005-06-01

    Studies of indoor allergen exposures are often limited by the cost and logistics of sending technicians to homes to collect dust. In this study we evaluated the feasibility of having subjects collect their own dust samples. The objectives were to compare allergen concentrations between subject- and technician-collected samples and to examine the sample return rate. Using a dust collection device and written instructions provided to them by mail, 102 subjects collected a combined dust sample from a bed and bedroom floor. Later the same day, a technician collected a side-by-side sample. Dust samples were weighed and analyzed for the cat allergen Fel d 1 and the dust mite allergen Der p 1. Fifty additional subjects who were enrolled by telephone were mailed dust collection packages and asked to return a dust sample and questionnaire by mail. A technician did not visit their homes. Correlations between subject- and technician-collected samples were strong for concentrations of Fel d 1 (r = 0.88) and Der p 1 (r = 0.87). With allergen concentrations dichotomized at lower limits of detection and clinically relevant thresholds, agreements between methodologies ranged from 91 to 98%. Although dust weights were correlated (r = 0.48, p < 0.001), subjects collected lighter samples. Among the group of 50 subjects, 46 returned a dust sample and completed questionnaire. The median number of days to receive a sample was 15. With some limitations, subject-collected dust sampling appears to be a valid and practical option for epidemiologic and clinical studies that report allergen concentration as a measure of exposure.

  20. Urine sampling and collection system

    NASA Technical Reports Server (NTRS)

    Fogal, G. L.; Mangialardi, J. K.; Reinhardt, C. G.

    1971-01-01

    This specification defines the performance and design requirements for the urine sampling and collection system engineering model and establishes requirements for its design, development, and test. The model shall provide conceptual verification of a system applicable to manned space flight which will automatically provide for collection, volume sensing, and sampling of urine.

  1. Sample collection of virulent and non-virulent B. anthracis and Y. pestis for bioforensics analysis

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Hong-geller, Elizabeth; Valdez, Yolanda E; Shou, Yulin

    2009-01-01

    Validated sample collection methods are needed for recovery of microbial evidence in the event of accidental or intentional release of biological agents into the environment. To address this need, we evaluated the sample recovery efficiencies of two collection methods -- swabs and wipes -- for both non-virulent and virulent strains of B. anthracis and Y. pestis from four types of non-porous surfaces: two hydrophilic surfaces, stainless steel and glass, and two hydrophobic surfaces, vinyl and plastic. Sample recovery was quantified using Real-time qPCR to assay for intact DNA signatures. We found no consistent difference in collection efficiency between swabs ormore » wipes. Furthermore, collection efficiency was more surface-dependent for virulent strains than non-virulent strains. For the two non-virulent strains, B. anthracis Sterne and Y. pestis A1122, collection efficiency was approximately 100% and 1 %, respectively, from all four surfaces. In contrast, recovery of B. anthracis Ames spores and Y. pestis C092 from vinyl and plastic was generally lower compared to collection from glass or stainless steel, suggesting that surface hydrophobicity may playa role in the strength of pathogen adhesion. The surface-dependent collection efficiencies observed with the virulent strains may arise from strain-specific expression of capsular material or other cell surface receptors that alter cell adhesion to specific surfaces. These findings contribute to validation of standard bioforensics procedures and emphasize the importance of specific strain and surface interactions in pathogen detection.« less

  2. [Location of semen collection and semen quality: clinic-collected versus home-collected samples].

    PubMed

    Wang, Wei; Zhong, Zhi-min; Su, Ning; Peng, Ya-ya; Huang, Ting-ting

    2014-11-01

    To investigate the differences in semen quality between samples collected by masturbation in the clinic and at home. Based on the WHO guidelines, we analyzed the ejaculates collected by masturbation in the clinic and at home from 342 men under infertility assessment and measured the contents of such biochemical markers in the seminal plasma as neutral α-glucosidase, zinc, and fructose. According to the location of semen collection, we divided the samples into two groups, clinic-collected and home-collected, and analyzed the differences in the semen parameters between the two groups with the SPSS 16.0 software. Compared with the clinic-collected semen, the home-collected samples had significantly higher mean values in semen volume (4.0 vs 4.9%), sperm concentration (41 vs 64 x 10(6)/ml), total sperm count (175 vs 270 x 10(6) per ejaculate), progressive sperm motility (40 vs 52%), total count of progressively motile sperm (82 vs 135 x 10(6) per ejaculate) (all P <0.05). No significant differences were found between the two groups in normal sperm morphology (4.0 vs 5.0%) and the contents of neutral α-glucosidase (26 vs 24 mU per ejaculate), zinc (8.0 vs 8.0 μmol per ejaculate), and fructose (62 vs 60 μmol per ejaculate) (all P >0.05). Abnormal sperm concentration (<20 x 10(6)/ml) was observed in significantly fewer of the home-collected samples than the clinic-collected ones (18% [62/342] vs 30% [103/342], P<0.05), and so was abnormal progressive sperm motility (<32%) (64% [219/342] vs 75% [256/342], P<0.05). Our findings show that semen samples collected by masturbation at home has a higher quality than those collected in the clinic. So the location of semen collection should be taken into consideration in infertility investigation.

  3. Performance of OncoE6 cervical test with collection methods enabling self-sampling.

    PubMed

    Krings, Amrei; Dückelmann, Anna M; Moser, Lutz; Gollrad, Johannes; Wiegerinck, Maarten; Schweizer, Johannes; Kaufmann, Andreas M

    2018-05-21

    The paradigm shift from cytological screening to Human Papillomavirus (HPV)-based screening for cervical cancer allows the introduction of new technologies in sample collection and diagnostics. The OncoE6™ Cervical Test (OncoE6 Test) is a rapid, easy-to-use lateral flow method detecting HPV16/18 E6 oncoproteins that has proven to detect high-grade cervical lesions with high specificity. If compatible with self-collection samples, this technology might allow for decentralized screening of hard-to-reach populations. For technical validation, cervicovaginal lavages were collected from 20 patients with confirmed HPV16+ or HPV18+ invasive cervical cancer. Cervical smears were collected by polyester-tipped swabs and cytobrushes. All samples were applied to the OncoE6 Test and cytobrush samples additionally genotyped. Lavage, swab, and cytobrush revealed concordant outcome in 18/20 samples. HPV types corresponded with the HPV genotyping by GP5+/6+ PCR analyses. Due to a rare mutation found in the E6 antibody binding site one sample was not detected, another sample had very low cellularity. Overall, vaginal lavages are technically adequate for the OncoE6 Test. Combining self-sampling with oncoprotein rapid testing to detect women with highest risk for severe dysplasia or cancer may allow for secondary cancer prevention in settings where other screening modalities were unsuccessful to date.

  4. Sample collection system for gel electrophoresis

    DOEpatents

    Olivares, Jose A.; Stark, Peter C.; Dunbar, John M.; Hill, Karen K.; Kuske, Cheryl R.; Roybal, Gustavo

    2004-09-21

    An automatic sample collection system for use with an electrophoretic slab gel system is presented. The collection system can be used with a slab gel have one or more lanes. A detector is used to detect particle bands on the slab gel within a detection zone. Such detectors may use a laser to excite fluorescently labeled particles. The fluorescent light emitted from the excited particles is transmitted to low-level light detection electronics. Upon the detection of a particle of interest within the detection zone, a syringe pump is activated, sending a stream of buffer solution across the lane of the slab gel. The buffer solution collects the sample of interest and carries it through a collection port into a sample collection vial.

  5. Design and validation of a wind tunnel system for odour sampling on liquid area sources.

    PubMed

    Capelli, L; Sironi, S; Del Rosso, R; Céntola, P

    2009-01-01

    The aim of this study is to describe the methods adopted for the design and the experimental validation of a wind tunnel, a sampling system suitable for the collection of gaseous samples on passive area sources, which allows to simulate wind action on the surface to be monitored. The first step of the work was the study of the air velocity profiles. The second step of the work consisted in the validation of the sampling system. For this purpose, the odour concentration of some air samples collected by means of the wind tunnel was measured by dynamic olfactometry. The results of the air velocity measurements show that the wind tunnel design features enabled the achievement of a uniform and homogeneous air flow through the hood. Moreover, the laboratory tests showed a very good correspondence between the odour concentration values measured at the wind tunnel outlet and the odour concentration values predicted by the application of a specific volatilization model, based on the Prandtl boundary layer theory. The agreement between experimental and theoretical trends demonstrate that the studied wind tunnel represents a suitable sampling system for the simulation of specific odour emission rates from liquid area sources without outward flow.

  6. Dynamic Method for Identifying Collected Sample Mass

    NASA Technical Reports Server (NTRS)

    Carson, John

    2008-01-01

    G-Sample is designed for sample collection missions to identify the presence and quantity of sample material gathered by spacecraft equipped with end effectors. The software method uses a maximum-likelihood estimator to identify the collected sample's mass based on onboard force-sensor measurements, thruster firings, and a dynamics model of the spacecraft. This makes sample mass identification a computation rather than a process requiring additional hardware. Simulation examples of G-Sample are provided for spacecraft model configurations with a sample collection device mounted on the end of an extended boom. In the absence of thrust knowledge errors, the results indicate that G-Sample can identify the amount of collected sample mass to within 10 grams (with 95-percent confidence) by using a force sensor with a noise and quantization floor of 50 micrometers. These results hold even in the presence of realistic parametric uncertainty in actual spacecraft inertia, center-of-mass offset, and first flexibility modes. Thrust profile knowledge is shown to be a dominant sensitivity for G-Sample, entering in a nearly one-to-one relationship with the final mass estimation error. This means thrust profiles should be well characterized with onboard accelerometers prior to sample collection. An overall sample-mass estimation error budget has been developed to approximate the effect of model uncertainty, sensor noise, data rate, and thrust profile error on the expected estimate of collected sample mass.

  7. Validation of the MODIS Collection 6 MCD64 Global Burned Area Product

    NASA Astrophysics Data System (ADS)

    Boschetti, L.; Roy, D. P.; Giglio, L.; Stehman, S. V.; Humber, M. L.; Sathyachandran, S. K.; Zubkova, M.; Melchiorre, A.; Huang, H.; Huo, L. Z.

    2017-12-01

    The research, policy and management applications of satellite products place a high priority on rigorously assessing their accuracy. A number of NASA, ESA and EU funded global and continental burned area products have been developed using coarse spatial resolution satellite data, and have the potential to become part of a long-term fire Essential Climate Variable. These products have usually been validated by comparison with reference burned area maps derived by visual interpretation of Landsat or similar spatial resolution data selected on an ad hoc basis. More optimally, a design-based validation method should be adopted, characterized by the selection of reference data via probability sampling. Design based techniques have been used for annual land cover and land cover change product validation, but have not been widely used for burned area products, or for other products that are highly variable in time and space (e.g. snow, floods, other non-permanent phenomena). This has been due to the challenge of designing an appropriate sampling strategy, and to the cost and limited availability of independent reference data. This paper describes the validation procedure adopted for the latest Collection 6 version of the MODIS Global Burned Area product (MCD64, Giglio et al, 2009). We used a tri-dimensional sampling grid that allows for probability sampling of Landsat data in time and in space (Boschetti et al, 2016). To sample the globe in the spatial domain with non-overlapping sampling units, the Thiessen Scene Area (TSA) tessellation of the Landsat WRS path/rows is used. The TSA grid is then combined with the 16-day Landsat acquisition calendar to provide tri-dimensonal elements (voxels). This allows the implementation of a sampling design where not only the location but also the time interval of the reference data is explicitly drawn through stratified random sampling. The novel sampling approach was used for the selection of a reference dataset consisting of 700

  8. Data Validation Package - July 2016 Groundwater Sampling at the Gunnison, Colorado, Disposal Site

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Linard, Joshua; Campbell, Sam

    Groundwater sampling at the Gunnison, Colorado, Disposal Site is conducted every 5 years to monitor disposal cell performance. During this event, samples were collected from eight monitoring wells as specified in the 1997 Long-Term Surveillance Plan for the Gunnison, Colorado, Disposal Site. Sampling and analyses were conducted as specified in the Sampling and Analysis Plan for US Department of Energy Office of Legacy Management Sites (LMS/PRO/S04351, continually updated, http://energy.gov/lm/downloads/sampling-and­ analysis-plan-us-department-energy-office-legacy-management-sites). Planned monitoring locations are shown in Attachment 1, Sampling and Analysis Work Order. A duplicate sample was collected from location 0723. Water levels were measured at all monitoring wells thatmore » were sampled and seven additional wells. The analytical data and associated qualifiers can be viewed in environmental database reports and are also available for viewing with dynamic mapping via the GEMS (Geospatial Environmental Mapping System) website at http://gems.lm.doe.gov/#. No issues were identified during the data validation process that require additional action or follow-up.« less

  9. Validation of a sampling plan to generate food composition data.

    PubMed

    Sammán, N C; Gimenez, M A; Bassett, N; Lobo, M O; Marcoleri, M E

    2016-02-15

    A methodology to develop systematic plans for food sampling was proposed. Long life whole and skimmed milk, and sunflower oil were selected to validate the methodology in Argentina. Fatty acid profile in all foods, proximal composition, and calcium's content in milk were determined with AOAC methods. The number of samples (n) was calculated applying Cochran's formula with variation coefficients ⩽12% and an estimate error (r) maximum permissible ⩽5% for calcium content in milks and unsaturated fatty acids in oil. n were 9, 11 and 21 for long life whole and skimmed milk, and sunflower oil respectively. Sample units were randomly collected from production sites and sent to labs. Calculated r with experimental data was ⩽10%, indicating high accuracy in the determination of analyte content of greater variability and reliability of the proposed sampling plan. The methodology is an adequate and useful tool to develop sampling plans for food composition analysis. Copyright © 2015 Elsevier Ltd. All rights reserved.

  10. 75 FR 43989 - Agency Information Collection Activities; Proposed Collection; Comment Request; Sample Collection...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-07-27

    ... for Dogs Treated With SLENTROL AGENCY: Food and Drug Administration, HHS. ACTION: Notice. SUMMARY: The... on the sample collection plan for dogs treated with the drug SLENTROL. DATES: Submit either... technology. Sample Collection Plan for Dogs Treated With SLENTROL--21 CFR 514.80 (OMB Control Number 0910-NEW...

  11. Technical note: Instantaneous sampling intervals validated from continuous video observation for behavioral recording of feedlot lambs.

    PubMed

    Pullin, A N; Pairis-Garcia, M D; Campbell, B J; Campler, M R; Proudfoot, K L

    2017-11-01

    When considering methodologies for collecting behavioral data, continuous sampling provides the most complete and accurate data set whereas instantaneous sampling can provide similar results and also increase the efficiency of data collection. However, instantaneous time intervals require validation to ensure accurate estimation of the data. Therefore, the objective of this study was to validate scan sampling intervals for lambs housed in a feedlot environment. Feeding, lying, standing, drinking, locomotion, and oral manipulation were measured on 18 crossbred lambs housed in an indoor feedlot facility for 14 h (0600-2000 h). Data from continuous sampling were compared with data from instantaneous scan sampling intervals of 5, 10, 15, and 20 min using a linear regression analysis. Three criteria determined if a time interval accurately estimated behaviors: 1) ≥ 0.90, 2) slope not statistically different from 1 ( > 0.05), and 3) intercept not statistically different from 0 ( > 0.05). Estimations for lying behavior were accurate up to 20-min intervals, whereas feeding and standing behaviors were accurate only at 5-min intervals (i.e., met all 3 regression criteria). Drinking, locomotion, and oral manipulation demonstrated poor associations () for all tested intervals. The results from this study suggest that a 5-min instantaneous sampling interval will accurately estimate lying, feeding, and standing behaviors for lambs housed in a feedlot, whereas continuous sampling is recommended for the remaining behaviors. This methodology will contribute toward the efficiency, accuracy, and transparency of future behavioral data collection in lamb behavior research.

  12. Sample Collection Information Document for Pathogens and ...

    EPA Pesticide Factsheets

    Report This Sample Collection Information Document (SCID) provides general information for use by EPA and its contractors when collecting samples during environmental remediation following a homeland security event. The document is intended to be used with SAM, and to provide information needed for collection of samples to be analyzed using the specific methods and procedures listed in SAM Revision 5.0.*

  13. 28 CFR 28.12 - Collection of DNA samples.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 28 Judicial Administration 1 2010-07-01 2010-07-01 false Collection of DNA samples. 28.12 Section 28.12 Judicial Administration DEPARTMENT OF JUSTICE DNA IDENTIFICATION SYSTEM DNA Sample Collection, Analysis, and Indexing § 28.12 Collection of DNA samples. (a) The Bureau of Prisons shall collect a DNA...

  14. 28 CFR 28.12 - Collection of DNA samples.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... 28 Judicial Administration 1 2011-07-01 2011-07-01 false Collection of DNA samples. 28.12 Section 28.12 Judicial Administration DEPARTMENT OF JUSTICE DNA IDENTIFICATION SYSTEM DNA Sample Collection, Analysis, and Indexing § 28.12 Collection of DNA samples. (a) The Bureau of Prisons shall collect a DNA...

  15. 28 CFR 28.12 - Collection of DNA samples.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... 28 Judicial Administration 1 2012-07-01 2012-07-01 false Collection of DNA samples. 28.12 Section 28.12 Judicial Administration DEPARTMENT OF JUSTICE DNA IDENTIFICATION SYSTEM DNA Sample Collection, Analysis, and Indexing § 28.12 Collection of DNA samples. (a) The Bureau of Prisons shall collect a DNA...

  16. 28 CFR 28.12 - Collection of DNA samples.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... 28 Judicial Administration 1 2014-07-01 2014-07-01 false Collection of DNA samples. 28.12 Section 28.12 Judicial Administration DEPARTMENT OF JUSTICE DNA IDENTIFICATION SYSTEM DNA Sample Collection, Analysis, and Indexing § 28.12 Collection of DNA samples. (a) The Bureau of Prisons shall collect a DNA...

  17. 28 CFR 28.12 - Collection of DNA samples.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... 28 Judicial Administration 1 2013-07-01 2013-07-01 false Collection of DNA samples. 28.12 Section 28.12 Judicial Administration DEPARTMENT OF JUSTICE DNA IDENTIFICATION SYSTEM DNA Sample Collection, Analysis, and Indexing § 28.12 Collection of DNA samples. (a) The Bureau of Prisons shall collect a DNA...

  18. Evaluation of Bacillus anthracis and Yersinia pestis sample collection from nonporous surfaces by quantitative real-time PCR.

    PubMed

    Hong-Geller, E; Valdez, Y E; Shou, Y; Yoshida, T M; Marrone, B L; Dunbar, J M

    2010-04-01

    We will validate sample collection methods for recovery of microbial evidence in the event of accidental or intentional release of biological agents into the environment. We evaluated the sample recovery efficiencies of two collection methods - swabs and wipes - for both nonvirulent and virulent strains of Bacillus anthracis and Yersinia pestis from four types of nonporous surfaces: two hydrophilic surfaces, stainless steel and glass, and two hydrophobic surfaces, vinyl and plastic. Sample recovery was quantified using real-time qPCR to assay for intact DNA signatures. We found no consistent difference in collection efficiency between swabs or wipes. Furthermore, collection efficiency was more surface-dependent for virulent strains than nonvirulent strains. For the two nonvirulent strains, collection efficiency was similar between all four surfaces, albeit B. anthracis Sterne exhibited higher levels of recovery compared to Y. pestis A1122. In contrast, recovery of B. anthracis Ames spores and Y. pestis CO92 from the hydrophilic glass or stainless steel surfaces was generally more efficient compared to collection from the hydrophobic vinyl and plastic surfaces. Our results suggest that surface hydrophobicity may play a role in the strength of pathogen adhesion. The surface-dependent collection efficiencies observed with the virulent strains may arise from strain-specific expression of capsular material or other cell surface receptors that alter cell adhesion to specific surfaces. These findings contribute to the validation of standard bioforensics procedures and emphasize the importance of specific strain and surface interactions in pathogen detection.

  19. Analysis of the research sample collections of Uppsala biobank.

    PubMed

    Engelmark, Malin T; Beskow, Anna H

    2014-10-01

    Uppsala Biobank is the joint and only biobank organization of the two principals, Uppsala University and Uppsala University Hospital. Biobanks are required to have updated registries on sample collection composition and management in order to fulfill legal regulations. We report here the results from the first comprehensive and overall analysis of the 131 research sample collections organized in the biobank. The results show that the median of the number of samples in the collections was 700 and that the number of samples varied from less than 500 to over one million. Blood samples, such as whole blood, serum, and plasma, were included in the vast majority, 84.0%, of the research sample collections. Also, as much as 95.5% of the newly collected samples within healthcare included blood samples, which further supports the concept that blood samples have fundamental importance for medical research. Tissue samples were also commonly used and occurred in 39.7% of the research sample collections, often combined with other types of samples. In total, 96.9% of the 131 sample collections included samples collected for healthcare, showing the importance of healthcare as a research infrastructure. Of the collections that had accessed existing samples from healthcare, as much as 96.3% included tissue samples from the Department of Pathology, which shows the importance of pathology samples as a resource for medical research. Analysis of different research areas shows that the most common of known public health diseases are covered. Collections that had generated the most publications, up to over 300, contained a large number of samples collected systematically and repeatedly over many years. More knowledge about existing biobank materials, together with public registries on sample collections, will support research collaborations, improve transparency, and bring us closer to the goals of biobanks, which is to save and prolong human lives and improve health and quality of life.

  20. Nonclinical dose formulation analysis method validation and sample analysis.

    PubMed

    Whitmire, Monica Lee; Bryan, Peter; Henry, Teresa R; Holbrook, John; Lehmann, Paul; Mollitor, Thomas; Ohorodnik, Susan; Reed, David; Wietgrefe, Holly D

    2010-12-01

    Nonclinical dose formulation analysis methods are used to confirm test article concentration and homogeneity in formulations and determine formulation stability in support of regulated nonclinical studies. There is currently no regulatory guidance for nonclinical dose formulation analysis method validation or sample analysis. Regulatory guidance for the validation of analytical procedures has been developed for drug product/formulation testing; however, verification of the formulation concentrations falls under the framework of GLP regulations (not GMP). The only current related regulatory guidance is the bioanalytical guidance for method validation. The fundamental parameters for bioanalysis and formulation analysis validations that overlap include: recovery, accuracy, precision, specificity, selectivity, carryover, sensitivity, and stability. Divergence in bioanalytical and drug product validations typically center around the acceptance criteria used. As the dose formulation samples are not true "unknowns", the concept of quality control samples that cover the entire range of the standard curve serving as the indication for the confidence in the data generated from the "unknown" study samples may not always be necessary. Also, the standard bioanalytical acceptance criteria may not be directly applicable, especially when the determined concentration does not match the target concentration. This paper attempts to reconcile the different practices being performed in the community and to provide recommendations of best practices and proposed acceptance criteria for nonclinical dose formulation method validation and sample analysis.

  1. Efficient Genome-Wide Sequencing and Low-Coverage Pedigree Analysis from Noninvasively Collected Samples

    PubMed Central

    Snyder-Mackler, Noah; Majoros, William H.; Yuan, Michael L.; Shaver, Amanda O.; Gordon, Jacob B.; Kopp, Gisela H.; Schlebusch, Stephen A.; Wall, Jeffrey D.; Alberts, Susan C.; Mukherjee, Sayan; Zhou, Xiang; Tung, Jenny

    2016-01-01

    Research on the genetics of natural populations was revolutionized in the 1990s by methods for genotyping noninvasively collected samples. However, these methods have remained largely unchanged for the past 20 years and lag far behind the genomics era. To close this gap, here we report an optimized laboratory protocol for genome-wide capture of endogenous DNA from noninvasively collected samples, coupled with a novel computational approach to reconstruct pedigree links from the resulting low-coverage data. We validated both methods using fecal samples from 62 wild baboons, including 48 from an independently constructed extended pedigree. We enriched fecal-derived DNA samples up to 40-fold for endogenous baboon DNA and reconstructed near-perfect pedigree relationships even with extremely low-coverage sequencing. We anticipate that these methods will be broadly applicable to the many research systems for which only noninvasive samples are available. The lab protocol and software (“WHODAD”) are freely available at www.tung-lab.org/protocols-and-software.html and www.xzlab.org/software.html, respectively. PMID:27098910

  2. Evaluation of a novel dried blood spot collection device (HemaSpot™) to test blood samples collected from dogs for antibodies to Leishmania infantum.

    PubMed

    Rosypal, Alexa C; Pick, Leanne D; Hernandez, Jaime O Esquivel; Lindsay, David S

    2014-09-15

    Collection of blood samples from veterinary and wildlife patients is often challenging because the samples have to be collected on farm or in the wild under various environmental conditions. This poses many technical problems associated with venipuncture materials, their safe use and disposal, transportation and processing of collected samples. Dried blood spot (DBS) sample collection techniques offer a simple and practical alternative to traditional blood collection methods to obtain blood samples from animals for parasite antibody evaluation. The DBS collection devices are compact, simple to use, and are particularly useful for large number of samples. Additionally, DBS samples take up less space and they are easier to transport than traditional venipuncture-collected blood samples. Visceral leishmaniasis (VL) is a potentially fatal parasitic disease of dogs and humans and it is frequently diagnosed by antibody tests. Immunochromatographic tests (ICT) for antibodies to Leishmania infantum are commercially available for dogs and they produce qualitative results in minutes. Measurement of canine antibodies to L. infantum with the ICT using traditional venipuncture has been validated previously, but the use of DBS samples has not been evaluated using this method. The purpose of the present study was to determine the ability of DBS samples to detect antibodies to L. infantum in dogs using a commercial ICT assay. One hundred plasma samples from dogs experimentally infected with the LIVT-1 strain of L. infantum were collected by venipuncture and frozen. Individual samples were thawed, and then 80 μl plasma (2 drops) was aliquotted onto the 8-spoked disk pad on individual DBS sample collection devices (HemaSpot™, Spot-On Sciences, Austin, TX), dried, and stored in the dark at room temperature. After one month and six months, respectively, 2 spokes of the 8 spokes of the disk pad of each DBS sample were removed and eluted in 200 μl PBS. The eluate was used to test

  3. Collecting Ground Samples for Balloon-Borne Instruments

    NASA Technical Reports Server (NTRS)

    Jones, Jack; Zimmerman, Wayne; Wu, Jiunn Jenq

    2009-01-01

    A proposed system in a gondola containing scientific instruments suspended by a balloon over the surface of the Saturn moon Titan would quickly acquire samples of rock or ice from the ground below. Prototypes of a sample-collecting device that would be a major part of the system have been tested under cryogenic and non-cryogenic conditions on Earth. Systems like this one could also be used in non-cryogenic environments on Earth to collect samples of rock, soil, ice, mud, or other ground material from such inaccessible or hazardous locations as sites of suspected chemical spills or biological contamination. The sample-collecting device would be a harpoonlike device that would be connected to the balloon-borne gondola by a tether long enough to reach the ground. The device would be dropped from the gondola to acquire a sample, then would be reeled back up to the gondola, where the sample would be analyzed by the onboard instruments. Each prototype of the sample-collecting device has a sharp front (lower) end, a hollow core for retaining a sample, a spring for holding the sample in the hollow core, and a rear (upper) annular cavity for retaining liquid sample material. Aerodynamic fins at the rear help to keep the front end pointed downward. In tests, these prototype devices were dropped from various heights and used to gather samples of dry sand, moist sand, cryogenic water ice, and warmer water ice.

  4. JSC Advanced Curation: Research and Development for Current Collections and Future Sample Return Mission Demands

    NASA Technical Reports Server (NTRS)

    Fries, M. D.; Allen, C. C.; Calaway, M. J.; Evans, C. A.; Stansbery, E. K.

    2015-01-01

    Curation of NASA's astromaterials sample collections is a demanding and evolving activity that supports valuable science from NASA missions for generations, long after the samples are returned to Earth. For example, NASA continues to loan hundreds of Apollo program samples to investigators every year and those samples are often analyzed using instruments that did not exist at the time of the Apollo missions themselves. The samples are curated in a manner that minimizes overall contamination, enabling clean, new high-sensitivity measurements and new science results over 40 years after their return to Earth. As our exploration of the Solar System progresses, upcoming and future NASA sample return missions will return new samples with stringent contamination control, sample environmental control, and Planetary Protection requirements. Therefore, an essential element of a healthy astromaterials curation program is a research and development (R&D) effort that characterizes and employs new technologies to maintain current collections and enable new missions - an Advanced Curation effort. JSC's Astromaterials Acquisition & Curation Office is continually performing Advanced Curation research, identifying and defining knowledge gaps about research, development, and validation/verification topics that are critical to support current and future NASA astromaterials sample collections. The following are highlighted knowledge gaps and research opportunities.

  5. 40 CFR 761.392 - Preparing validation study samples.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... establish a surface concentration to be included in the standard operating procedure. The surface levels of... Under § 761.79(d)(4) § 761.392 Preparing validation study samples. (a)(1) To validate a procedure to... surfaces must be ≥20 µg/100 cm2. (2) To validate a procedure to decontaminate a specified surface...

  6. 40 CFR 761.392 - Preparing validation study samples.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... establish a surface concentration to be included in the standard operating procedure. The surface levels of... Under § 761.79(d)(4) § 761.392 Preparing validation study samples. (a)(1) To validate a procedure to... surfaces must be ≥20 µg/100 cm2. (2) To validate a procedure to decontaminate a specified surface...

  7. 40 CFR 761.392 - Preparing validation study samples.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... establish a surface concentration to be included in the standard operating procedure. The surface levels of... Under § 761.79(d)(4) § 761.392 Preparing validation study samples. (a)(1) To validate a procedure to... surfaces must be ≥20 µg/100 cm2. (2) To validate a procedure to decontaminate a specified surface...

  8. Data Validation Package - April and July 2015 Groundwater and Surface Water Sampling at the Gunnison, Colorado, Processing Site

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Linard, Joshua; Campbell, Sam

    This event included annual sampling of groundwater and surface water locations at the Gunnison, Colorado, Processing Site. Sampling and analyses were conducted as specified in Sampling and Analysis Plan for U.S. Department of Energy Office of Legacy Management Sites. Samples were collected from 28 monitoring wells, three domestic wells, and six surface locations in April at the processing site as specified in the 2010 Ground Water Compliance Action Plan for the Gunnison, Colorado, Processing Site. Domestic wells 0476 and 0477 were sampled in July because the homes were unoccupied in April, and the wells were not in use. Duplicate samplesmore » were collected from locations 0113, 0248, and 0477. One equipment blank was collected during this sampling event. Water levels were measured at all monitoring wells that were sampled. No issues were identified during the data validation process that requires additional action or follow-up.« less

  9. USEPA/USGS Sample Collection Protocol for Bacterial ...

    EPA Pesticide Factsheets

    Report/SOP This Sample Collection Procedure (SCP) describes the activities and considerations for the collection of bacterial pathogens from representative surface soil samples (0-5 cm). This sampling depth can be reached without the use of a drill rig, direct-push technology, or other mechanized equipment. Analizing soil samples for biothreat agents may, for instance, define the extent of contamination or determine whether the concentrations of contaminants present a risk to public health, welfare, or the environment.

  10. Matrix isolation apparatus with extended sample collection capability

    DOEpatents

    Reedy, Gerald T.

    1987-01-01

    A gas-sample collection device provides for the matrix isolation of increased amounts of a sample material for spectrographic analysis from a gas chromatographic separation. The device includes an evacuated sample collection chamber containing a disc-like specular carousel having a generally circular lateral surface upon which the sample is deposited in an inert gas matrix for infrared (IR) spectral analysis. The evacuated sample chamber is mounted in a fixed manner and is coupled to and supports a rotating cryostatic coupler which, in turn, supports the specular carousel within the collection chamber. A rotational drive system connected to the cryostatic coupler provides for its rotational displacement as well as that of the sample collecting carousel. In addition, rotation of the cryostatic coupler effects vertical displacement of the carousel to permit the collection of an extended sample band in a helical configuration on the entire lateral surface of the carousel. The various components of the carousel's angular/linear displacement drive system are located exterior to the cryostatic coupler for easy access and improved operation. The cryostatic coupler includes a 360.degree. rotary union assembly for permitting the delivery of a high pressure working fluid to the cryostatic coupler in a continuous flow manner for maintaining the specular carousel at a low temperature, e.g., 10.degree.-20.degree. K., for improved uninterrupted gas sample collection and analysis.

  11. Review of sampling, sample and data collection procedures in nursing research--An example of research on ethical climate as perceived by nurses.

    PubMed

    Suhonen, Riitta; Stolt, Minna; Katajisto, Jouko; Leino-Kilpi, Helena

    2015-12-01

    To report a review of quality regarding sampling, sample and data collection procedures of empirical nursing research of ethical climate studies where nurses were informants. Surveys are needed to obtain generalisable information about topics sensitive to nursing. Methodological quality of the studies is of key concern, especially the description of sampling and data collection procedures. Methodological literature review. Using the electronic MEDLINE database, empirical nursing research articles focusing on ethical climate were accessed in 2013 (earliest-22 November 2013). Using the search terms 'ethical' AND ('climate*' OR 'environment*') AND ('nurse*' OR 'nursing'), 376 citations were retrieved. Based on a four-phase retrieval process, 26 studies were included in the detailed analysis. Sampling method was reported in 58% of the studies, and it was random in a minority of the studies (26%). The identification of target sample and its size (92%) was reported, whereas justification for sample size was less often given. In over two-thirds (69%) of the studies with identifiable response rate, it was below 75%. A variety of data collection procedures were used with large amount of missing data about the details of who distributed, recruited and collected the questionnaires. Methods to increase response rates were seldom described. Discussion about nonresponse, representativeness of the sample and generalisability of the results was missing in many studies. This review highlights the methodological challenges and developments that need to be considered in ensuring the use of valid information in developing health care through research findings. © 2015 Nordic College of Caring Science.

  12. The development of a Martian atmospheric Sample collection canister

    NASA Astrophysics Data System (ADS)

    Kulczycki, E.; Galey, C.; Kennedy, B.; Budney, C.; Bame, D.; Van Schilfgaarde, R.; Aisen, N.; Townsend, J.; Younse, P.; Piacentine, J.

    The collection of an atmospheric sample from Mars would provide significant insight to the understanding of the elemental composition and sub-surface out-gassing rates of noble gases. A team of engineers at the Jet Propulsion Laboratory (JPL), California Institute of Technology have developed an atmospheric sample collection canister for Martian application. The engineering strategy has two basic elements: first, to collect two separately sealed 50 cubic centimeter unpressurized atmospheric samples with minimal sensing and actuation in a self contained pressure vessel; and second, to package this atmospheric sample canister in such a way that it can be easily integrated into the orbiting sample capsule for collection and return to Earth. Sample collection and integrity are demonstrated by emulating the atmospheric collection portion of the Mars Sample Return mission on a compressed timeline. The test results achieved by varying the pressure inside of a thermal vacuum chamber while opening and closing the valve on the sample canister at Mars ambient pressure. A commercial off-the-shelf medical grade micro-valve is utilized in the first iteration of this design to enable rapid testing of the system. The valve has been independently leak tested at JPL to quantify and separate the leak rates associated with the canister. The results are factored in to an overall system design that quantifies mass, power, and sensing requirements for a Martian atmospheric Sample Collection (MASC) canister as outlined in the Mars Sample Return mission profile. Qualitative results include the selection of materials to minimize sample contamination, preliminary science requirements, priorities in sample composition, flight valve selection criteria, a storyboard from sample collection to loading in the orbiting sample capsule, and contributions to maintaining “ Earth” clean exterior surfaces on the orbiting sample capsule.

  13. Evaluation of standardized sample collection, packaging, and ...

    EPA Pesticide Factsheets

    Journal Sample collection procedures and primary receptacle (sample container and bag) decontamination methods should prevent contaminant transfer between contaminated and non-contaminated surfaces and areas during bio-incident operations. Cross-contamination of personnel, equipment, or sample containers may result in the exfiltration of biological agent from the exclusion (hot) zone and have unintended negative consequences on response resources, activities and outcomes. The current study was designed to: (1) evaluate currently recommended sample collection and packaging procedures to identify procedural steps that may increase the likelihood of spore exfiltration or contaminant transfer; (2) evaluate the efficacy of currently recommended primary receptacle decontamination procedures; and (3) evaluate the efficacy of outer packaging decontamination methods. Wet- and dry-deposited fluorescent tracer powder was used in contaminant transfer tests to qualitatively evaluate the currently-recommended sample collection procedures. Bacillus atrophaeus spores, a surrogate for Bacillus anthracis, were used to evaluate the efficacy of spray- and wipe-based decontamination procedures.

  14. Conducting Internet Research With the Transgender Population: Reaching Broad Samples and Collecting Valid Data.

    PubMed

    Miner, Michael H; Bockting, Walter O; Romine, Rebecca Swinburne; Raman, Sivakumaran

    2012-05-01

    Health research on transgender people has been hampered by the challenges inherent in studying a hard-to-reach, relatively small, and geographically dispersed population. The Internet has the potential to facilitate access to transgender samples large enough to permit examination of the diversity and syndemic health disparities found among this population. In this article, we describe the experiences of a team of investigators using the Internet to study HIV risk behaviors of transgender people in the United States. We developed an online instrument, recruited participants exclusively via websites frequented by members of the target population, and collected data using online quantitative survey and qualitative synchronous and asynchronous interview methods. Our experiences indicate that the Internet environment presents the investigator with some unique challenges and that commonly expressed criticisms about Internet research (e.g., lack of generalizable samples, invalid study participants, and multiple participation by the same subject) can be overcome with careful method design, usability testing, and pilot testing. The importance of both usability and pilot testing are described with respect to participant engagement and retention and the quality of data obtained online.

  15. Barratt collects sample from WRS

    NASA Image and Video Library

    2009-05-19

    ISS019-E-017918 (19 May 2009) --- Astronaut Michael Barratt, Expedition 19/20 flight engineer, collects a sample from the Water Recovery System (WRS) in the Destiny laboratory of the International Space Station.

  16. Biopolymers for sample collection, protection, and preservation.

    PubMed

    Sorokulova, Iryna; Olsen, Eric; Vodyanoy, Vitaly

    2015-07-01

    One of the principal challenges in the collection of biological samples from air, water, and soil matrices is that the target agents are not stable enough to be transferred from the collection point to the laboratory of choice without experiencing significant degradation and loss of viability. At present, there is no method to transport biological samples over considerable distances safely, efficiently, and cost-effectively without the use of ice or refrigeration. Current techniques of protection and preservation of biological materials have serious drawbacks. Many known techniques of preservation cause structural damages, so that biological materials lose their structural integrity and viability. We review applications of a novel bacterial preservation process, which is nontoxic and water soluble and allows for the storage of samples without refrigeration. The method is capable of protecting the biological sample from the effects of environment for extended periods of time and then allows for the easy release of these collected biological materials from the protective medium without structural or DNA damage. Strategies for sample collection, preservation, and shipment of bacterial, viral samples are described. The water-soluble polymer is used to immobilize the biological material by replacing the water molecules within the sample with molecules of the biopolymer. The cured polymer results in a solid protective film that is stable to many organic solvents, but quickly removed by the application of the water-based solution. The process of immobilization does not require the use of any additives, accelerators, or plastifiers and does not involve high temperature or radiation to promote polymerization.

  17. Reliability and validity of an Internet traumatic stress survey with a college student sample.

    PubMed

    Fortson, Beverly L; Scotti, Joseph R; Del Ben, Kevin S; Chen, Yi-Chuen

    2006-10-01

    The reliability and validity of Internet-based questionnaires were assessed in a sample of undergraduates (N = 411) by comparing data collected via the Internet with data collected in a more traditional format. A 2 x 2 x 2 repeated measures factorial design was used, forming four groups: Paper-Paper, Paper-Internet, Internet-Paper, and Internet-Internet. Scores on measures of trauma exposure, depression, and posttraumatic stress symptoms formed the dependent variables. Statistical analyses demonstrated that the psychometric properties of Internet-based questionnaires are similar to those established via formats that are more traditional. Questionnaire format and presentation order did not affect rates of psychological symptoms endorsed by participants. Researchers can feel comfortable that Internet data collection is a viable--and reliable--means for conducting trauma research.

  18. Comparative Evaluation of Drug Deposition in Hair Samples Collected from Different Anatomical Body Sites.

    PubMed

    Tzatzarakis, Manolis N; Alegakis, Athanasios K; Kavvalakis, Matthaios P; Vakonaki, Elena; Stivaktakis, Polychronis D; Kanaki, Katerina; Vardavas, Alexander I; Barbounis, Emmanouil G; Tsatsakis, Aristidis M

    2017-04-01

    In this study, we focused on the validation of a method for the simultaneous detection and quantification of cannabinoids, cocaine and opiates in hair as well as on the distribution of the drugs deposition in hair collected from different anatomical body sites. The proposed analytical procedure was validated for various parameters such as selectivity, linearity, limit of quantification, precision, accuracy, matrix effect and recovery. Four hundred and eighty-one samples were collected during 2010-2015 from 231 drug abusers. A 6-h ultrasonic-assisted methanolic extraction was applied for the isolation of the drugs. The analysis was performed in an liquid chromatography-mass spectrometry system for the opiates and cocaine and in a gas chromatography-mass spectrometry system for the cannabinoids. Cocaine was the most frequent detected drug (68.8-80.5%) followed by cannabinoids (47.6-63.3%) and opiates (34.7-46.7%) depending on the body site that the samples were collected. The mean concentrations of Δ9-tetrahydrocannabinol (THC) were 0.63 ± 2.11 for head, 0.54 ± 1.03 for pubic, 0.34 ± 0.51 for axillary and 0.18 ± 0.18 ng/mg for chest hair samples. The values of cocaine were 6.52 ± 15.98, 4.64 ± 10.77, 6.96 ± 38.21 and 3.94 ± 6.35 ng/mg, while the values of 6-monoacetylmorphine (MAM) were 3.33 ± 5.89, 3.06 ± 9.33, 1.37 ± 1.37 and 16.4 ± 1.77 ng/mg for head, pubic, axillary and chest samples, respectively. Differences between the detected concentrations of cocaine and opiates between the hair samples of different anatomical sites, as well as the ratio of drug metabolites to the parent compounds were observed in some cases. Statistically significant differences in the mean detected levels were noticed for morphine and heroin between head and pubic hair and also for cocaine and benzoylecgonine, between head and axillary hair samples. Moreover, the ratio of MAM to morphine and THC to cannabinol seems to correlate statistically with the total opiate or

  19. Validating internet research: a test of the psychometric equivalence of internet and in-person samples.

    PubMed

    Meyerson, Paul; Tryon, Warren W

    2003-11-01

    This study evaluated the psychometric equivalency of Web-based research. The Sexual Boredom Scale was presented via the World-Wide Web along with five additional scales used to validate it. A subset of 533 participants that matched a previously published sample (Watt & Ewing, 1996) on age, gender, and race was identified. An 8 x 8 correlation matrix from the matched Internet sample was compared via structural equation modeling with a similar 8 x 8 correlation matrix from the previously published study. The Internet and previously published samples were psychometrically equivalent. Coefficient alpha values calculated on the matched Internet sample yielded reliability coefficients almost identical to those for the previously published sample. Factors such as computer administration and uncontrollable administration settings did not appear to affect the results. Demographic data indicated an overrepresentation of males by about 6% and Caucasians by about 13% relative to the U.S. Census (2000). A total of 2,230 participants were obtained in about 8 months without remuneration. These results suggest that data collection on the Web is (1) reliable, (2) valid, (3) reasonably representative, (4) cost effective, and (5) efficient.

  20. Conducting Internet Research With the Transgender Population: Reaching Broad Samples and Collecting Valid Data

    PubMed Central

    Miner, Michael H.; Bockting, Walter O.; Romine, Rebecca Swinburne; Raman, Sivakumaran

    2013-01-01

    Health research on transgender people has been hampered by the challenges inherent in studying a hard-to-reach, relatively small, and geographically dispersed population. The Internet has the potential to facilitate access to transgender samples large enough to permit examination of the diversity and syndemic health disparities found among this population. In this article, we describe the experiences of a team of investigators using the Internet to study HIV risk behaviors of transgender people in the United States. We developed an online instrument, recruited participants exclusively via websites frequented by members of the target population, and collected data using online quantitative survey and qualitative synchronous and asynchronous interview methods. Our experiences indicate that the Internet environment presents the investigator with some unique challenges and that commonly expressed criticisms about Internet research (e.g., lack of generalizable samples, invalid study participants, and multiple participation by the same subject) can be overcome with careful method design, usability testing, and pilot testing. The importance of both usability and pilot testing are described with respect to participant engagement and retention and the quality of data obtained online. PMID:24031157

  1. Data Validation Package - June 2016 Groundwater and Surface Water Sampling at the Green River, Utah, Disposal Site

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Linard, Joshua; Price, Jeffrey

    This event included annual sampling of groundwater and surface water locations at the Green River, Utah, Disposal Site. Sampling and analyses were conducted as specified in Sampling and Analysis Plan for US. Department of Energy Office of Legacy Management Sites (LMS/PRO/S04351, continually updated, http://energy.gov/lrnldownloads/sampling-and- analysis-plan-us-department-energy-office-legacy-management-sites). Samples were collected from 15 monitoring wells and two surface locations at the disposal site as specified in the draft 2011 Ground Water Compliance Action Plan for the Green River, Utah, Disposal Site. Planned monitoring locations are shown in Attachment 1, Sampling and Analysis Work Order. A duplicate sample was collected from location 0179. Onemore » equipment blank was collected during this sampling event. Water levels were measured at all monitoring wells that were sampled. See Attachment 2, Trip Reports for additional details. The analytical data and associated qualifiers can be viewed in environmental database reports and are also available for viewing with dynamic mapping via the GEMS (Geospatial Environmental Mapping System) website at http://gems.lm.doe.gov/#. No issues were identified during the data validation process that requires additional action or follow-up.« less

  2. Total airborne mold particle sampling: evaluation of sample collection, preparation and counting procedures, and collection devices.

    PubMed

    Godish, Diana; Godish, Thad

    2008-02-01

    This study was conducted to evaluate (i) procedures used to collect, prepare, and count total airborne mold spore/particle concentrations, and (ii) the relative field performance of three commercially available total airborne mold spore/particle sampling devices. Differences between factory and laboratory airflow calibration values of axial fan-driven sampling instruments (used in the study) indicated a need for laboratory calibration using a mass flow meter to ensure that sample results were accurately calculated. An aniline blue-amended Calberla's solution adjusted to a pH of 4.2-4.4 provided good sample mounting/counting results using Dow Corning high vacuum grease, Dow Corning 280A adhesive, and Dow Corning 316 silicone release spray for samples collected using mini-Burkard and Allergenco samplers. Count variability among analysts was most pronounced in 5% counts of relatively low mold particle deposition density samples and trended downward with increased count percentage and particle deposition density. No significant differences were observed among means of 5, 10, and 20% counts and among analysts; a significant interaction effect was observed between analysts' counts and particle deposition densities. Significantly higher mini-Burkard and Air-O-Cell total mold spore/particle counts for 600x vs. 400x (1.9 and 2.3 x higher, respectively), 1000x vs. 600x (1.9 and 2.2 x higher, respectively) and 1000x vs. 400x (3.6 and 4.6 x higher, respectively) comparisons indicated that 1000x magnification counts best quantified total airborne mold spore/particles using light microscopy, and that lower magnification counts may result in unacceptable underreporting of airborne mold spore/particle concentrations. Modest but significantly higher (1.2x) total mold spore concentrations were observed with Allergenco vs. mini-Burkard samples collected in co-located, concurrently operated sampler studies; moderate but significantly higher mini-Burkard count values (1.4x) were

  3. Anthrax Detection: Agencies Need to Validate Sampling Activities in Order to Increase Confidence in Negative Results

    DTIC Science & Technology

    2005-03-01

    validate all activities related to other biothreat agents. In September and October 2001, letters laced with Bacillus anthracis (anthrax) spores were...2001, contaminated letters laced with Bacillus anthracis, or anthrax spores ,1 were sent through the mail to two senators, Thomas Daschle and Patrick...equipped workforce collecting the environmental samples; maximized isolation of viable Bacillus anthracis through preservation of spores during transport

  4. Cluster designs to assess the prevalence of acute malnutrition by lot quality assurance sampling: a validation study by computer simulation

    PubMed Central

    Olives, Casey; Pagano, Marcello; Deitchler, Megan; Hedt, Bethany L; Egge, Kari; Valadez, Joseph J

    2009-01-01

    Traditional lot quality assurance sampling (LQAS) methods require simple random sampling to guarantee valid results. However, cluster sampling has been proposed to reduce the number of random starting points. This study uses simulations to examine the classification error of two such designs, a 67×3 (67 clusters of three observations) and a 33×6 (33 clusters of six observations) sampling scheme to assess the prevalence of global acute malnutrition (GAM). Further, we explore the use of a 67×3 sequential sampling scheme for LQAS classification of GAM prevalence. Results indicate that, for independent clusters with moderate intracluster correlation for the GAM outcome, the three sampling designs maintain approximate validity for LQAS analysis. Sequential sampling can substantially reduce the average sample size that is required for data collection. The presence of intercluster correlation can impact dramatically the classification error that is associated with LQAS analysis. PMID:20011037

  5. Cluster designs to assess the prevalence of acute malnutrition by lot quality assurance sampling: a validation study by computer simulation.

    PubMed

    Olives, Casey; Pagano, Marcello; Deitchler, Megan; Hedt, Bethany L; Egge, Kari; Valadez, Joseph J

    2009-04-01

    Traditional lot quality assurance sampling (LQAS) methods require simple random sampling to guarantee valid results. However, cluster sampling has been proposed to reduce the number of random starting points. This study uses simulations to examine the classification error of two such designs, a 67x3 (67 clusters of three observations) and a 33x6 (33 clusters of six observations) sampling scheme to assess the prevalence of global acute malnutrition (GAM). Further, we explore the use of a 67x3 sequential sampling scheme for LQAS classification of GAM prevalence. Results indicate that, for independent clusters with moderate intracluster correlation for the GAM outcome, the three sampling designs maintain approximate validity for LQAS analysis. Sequential sampling can substantially reduce the average sample size that is required for data collection. The presence of intercluster correlation can impact dramatically the classification error that is associated with LQAS analysis.

  6. Adaptive Sampling-Based Information Collection for Wireless Body Area Networks.

    PubMed

    Xu, Xiaobin; Zhao, Fang; Wang, Wendong; Tian, Hui

    2016-08-31

    To collect important health information, WBAN applications typically sense data at a high frequency. However, limited by the quality of wireless link, the uploading of sensed data has an upper frequency. To reduce upload frequency, most of the existing WBAN data collection approaches collect data with a tolerable error. These approaches can guarantee precision of the collected data, but they are not able to ensure that the upload frequency is within the upper frequency. Some traditional sampling based approaches can control upload frequency directly, however, they usually have a high loss of information. Since the core task of WBAN applications is to collect health information, this paper aims to collect optimized information under the limitation of upload frequency. The importance of sensed data is defined according to information theory for the first time. Information-aware adaptive sampling is proposed to collect uniformly distributed data. Then we propose Adaptive Sampling-based Information Collection (ASIC) which consists of two algorithms. An adaptive sampling probability algorithm is proposed to compute sampling probabilities of different sensed values. A multiple uniform sampling algorithm provides uniform samplings for values in different intervals. Experiments based on a real dataset show that the proposed approach has higher performance in terms of data coverage and information quantity. The parameter analysis shows the optimized parameter settings and the discussion shows the underlying reason of high performance in the proposed approach.

  7. Techniques to Collect and Analyze the Cognitive Map Knowledge of Persons with Visual Impairment or Blindness: Issues of Validity.

    ERIC Educational Resources Information Center

    Kitchin, R. M.; Jacobson, R. D.

    1997-01-01

    Assesses techniques used by researchers to collect and analyze data on how people with visual impairments or blindness learn, understand, and think about geographic space. Recommendations are made for increasing the validity of studies, including the use of multiple, mutually supportive tests; larger samples; and real-world environments.…

  8. Adaptive Sampling-Based Information Collection for Wireless Body Area Networks

    PubMed Central

    Xu, Xiaobin; Zhao, Fang; Wang, Wendong; Tian, Hui

    2016-01-01

    To collect important health information, WBAN applications typically sense data at a high frequency. However, limited by the quality of wireless link, the uploading of sensed data has an upper frequency. To reduce upload frequency, most of the existing WBAN data collection approaches collect data with a tolerable error. These approaches can guarantee precision of the collected data, but they are not able to ensure that the upload frequency is within the upper frequency. Some traditional sampling based approaches can control upload frequency directly, however, they usually have a high loss of information. Since the core task of WBAN applications is to collect health information, this paper aims to collect optimized information under the limitation of upload frequency. The importance of sensed data is defined according to information theory for the first time. Information-aware adaptive sampling is proposed to collect uniformly distributed data. Then we propose Adaptive Sampling-based Information Collection (ASIC) which consists of two algorithms. An adaptive sampling probability algorithm is proposed to compute sampling probabilities of different sensed values. A multiple uniform sampling algorithm provides uniform samplings for values in different intervals. Experiments based on a real dataset show that the proposed approach has higher performance in terms of data coverage and information quantity. The parameter analysis shows the optimized parameter settings and the discussion shows the underlying reason of high performance in the proposed approach. PMID:27589758

  9. Citizen science networks in natural history and the collective validation of biodiversity data.

    PubMed

    Turnhout, Esther; Lawrence, Anna; Turnhout, Sander

    2016-06-01

    Biodiversity data are in increasing demand to inform policy and management. A substantial portion of these data is generated in citizen science networks. To ensure the quality of biodiversity data, standards and criteria for validation have been put in place. We used interviews and document analysis from the United Kingdom and The Netherlands to examine how data validation serves as a point of connection between the diverse people and practices in natural history citizen science networks. We found that rather than a unidirectional imposition of standards, validation was performed collectively. Specifically, it was enacted in ongoing circulations of biodiversity records between recorders and validators as they jointly negotiated the biodiversity that was observed and the validity of the records. These collective validation practices contributed to the citizen science character or natural history networks and tied these networks together. However, when biodiversity records were included in biodiversity-information initiatives on different policy levels and scales, the circulation of records diminished. These initiatives took on a more extractive mode of data use. Validation ceased to be collective with important consequences for the natural history networks involved and citizen science more generally. © 2016 The Authors. Conservation Biology published by Wiley Periodicals, Inc. on behalf of Society for Conservation Biology.

  10. Scientific guidelines for preservation of samples collected from Mars

    NASA Technical Reports Server (NTRS)

    Gooding, James L. (Editor)

    1990-01-01

    The maximum scientific value of Martian geologic and atmospheric samples is retained when the samples are preserved in the conditions that applied prior to their collection. Any sample degradation equates to loss of information. Based on detailed review of pertinent scientific literature, and advice from experts in planetary sample analysis, number values are recommended for key parameters in the environmental control of collected samples with respect to material contamination, temperature, head-space gas pressure, ionizing radiation, magnetic fields, and acceleration/shock. Parametric values recommended for the most sensitive geologic samples should also be adequate to preserve any biogenic compounds or exobiological relics.

  11. Automated collection and processing of environmental samples

    DOEpatents

    Troyer, Gary L.; McNeece, Susan G.; Brayton, Darryl D.; Panesar, Amardip K.

    1997-01-01

    For monitoring an environmental parameter such as the level of nuclear radiation, at distributed sites, bar coded sample collectors are deployed and their codes are read using a portable data entry unit that also records the time of deployment. The time and collector identity are cross referenced in memory in the portable unit. Similarly, when later recovering the collector for testing, the code is again read and the time of collection is stored as indexed to the sample collector, or to a further bar code, for example as provided on a container for the sample. The identity of the operator can also be encoded and stored. After deploying and/or recovering the sample collectors, the data is transmitted to a base processor. The samples are tested, preferably using a test unit coupled to the base processor, and again the time is recorded. The base processor computes the level of radiation at the site during exposure of the sample collector, using the detected radiation level of the sample, the delay between recovery and testing, the duration of exposure and the half life of the isotopes collected. In one embodiment, an identity code and a site code are optically read by an image grabber coupled to the portable data entry unit.

  12. Can human papillomavirus DNA testing of self-collected vaginal samples compare with physician-collected cervical samples and cytology for cervical cancer screening in developing countries?

    PubMed Central

    Bhatla, Neerja; Dar, Lalit; Patro, A. Rajkumar; Kumar, Pankaj; Kriplani, Alka; Gulati, Arti; Iyer, Venkateswaran K.; Mathur, Sandeep R.; Sreenivas, Vishnubhatla; Shah, Keerti V.; Gravitt, Patti E.

    2013-01-01

    Background To determine human papillomavirus (HPV) types by polymerase chain reaction (PCR)-reverse line blot assay and examine the concordance between HPV by Hybrid Capture 2 (HC2) and PCR on self-collected vaginal and physician-collected cervical samples and cytology. Methods This was a cross-sectional study of 546 sexually active women aged ≥30 years with persistent vaginal discharge, intermenstrual or postcoital bleeding or an unhealthy cervix. Participants self-collected vaginal samples (HPV-S) and physicians collected cervical samples for conventional Pap smear and HPV DNA (HPV-P) testing and performed colposcopy, with directed biopsy, if indicated. HPV testing and genotyping was done by HC2 and PCR reverse line blot assay. Concordance between HC2 and PCR results of self- and physician-collected samples was determined using a Kappa statistic (κ) and Chi-square test. Results Complete data were available for 512 sets with 98% of women providing a satisfactory self-sample. PCR detected oncogenic HPV in 12.3% of self- and 13.0% of physician-collected samples. Overall, there was 93.8% agreement between physician-collected and self-samples (κ = 76.31%, 95% confidence interval [CI]: 64.97–82.29%, p = 0.04)—complete concordance in 473 cases (57 positive, 416 negative), partial concordance in seven pairs and discordance in 32 pairs. The sensitivity, specificity, positive predictive value (PPV) and negative predictive value (NPV) of self-sampling for detection of cervical intraepithelial neoplasia (CIN)2+ disease were 82.5%, 93.6%, 52.4% and 98.4%, respectively; for physician-sampling they were 87.5%, 93.2%, 52.2% and 98.9%, respectively; and for cytology they were 77.5%, 87.3%, 34.1% and 97.9%, respectively. Concordance between HC2 and PCR was 90.9% for self-samples (κ = 63.7%, 95% CI: 55.2–72.2%) and 95.3% for physician-collected samples (κ = 80.4%, 95% CI: 71.8–89.0%). Conclusions Self-HPV sampling compares favourably with physician-sampling and

  13. Simultaneous LC-MS/MS quantitation of acetaminophen and its glucuronide and sulfate metabolites in human dried blood spot samples collected by subjects in a pilot clinical study.

    PubMed

    Li, Wenkui; Doherty, John P; Kulmatycki, Kenneth; Smith, Harold T; Tse, Francis Ls

    2012-06-01

    In support of a pilot clinical trial using acetaminophen as the model compound to assess dried blood spot (DBS) sampling as the method for clinical pharmacokinetic sample collection, a novel sensitive LC-MS/MS method was developed and validated for the simultaneous determination of acetaminophen and its major metabolites, acetaminophen glucuronide and sulfate, in human DBS samples collected by subjects via fingerprick. The validated assay dynamic range was from 50.0 to 5000 ng/ml for each compound using a 1/8´´ (3-mm) disc punched from a DBS sample. Baseline separation of the three analytes was achieved to eliminate the possible impact of insource fragmentation of the conjugated metabolites on the analysis of the parent. The overall extraction efficiency was from 61.3 to 78.8% for the three analytes by direct extraction using methanol. The validated method was successfully implemented in the pilot clinical study with the obtained pharmacokinetic parameters in agreement with the values reported in literature.

  14. 40 CFR 761.286 - Sample size and procedure for collecting a sample.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... collecting a sample. 761.286 Section 761.286 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY... On-Site Disposal of Bulk PCB Remediation Waste and Porous Surfaces in Accordance With § 761.61(a)(6... PCB remediation waste or porous surfaces, collect at least 20 milliliters of waste, or a portion of...

  15. 40 CFR 761.286 - Sample size and procedure for collecting a sample.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... collecting a sample. 761.286 Section 761.286 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY... On-Site Disposal of Bulk PCB Remediation Waste and Porous Surfaces in Accordance With § 761.61(a)(6... PCB remediation waste or porous surfaces, collect at least 20 milliliters of waste, or a portion of...

  16. 40 CFR 761.286 - Sample size and procedure for collecting a sample.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... collecting a sample. 761.286 Section 761.286 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY... On-Site Disposal of Bulk PCB Remediation Waste and Porous Surfaces in Accordance With § 761.61(a)(6... PCB remediation waste or porous surfaces, collect at least 20 milliliters of waste, or a portion of...

  17. 40 CFR 761.286 - Sample size and procedure for collecting a sample.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... collecting a sample. 761.286 Section 761.286 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY... On-Site Disposal of Bulk PCB Remediation Waste and Porous Surfaces in Accordance With § 761.61(a)(6... PCB remediation waste or porous surfaces, collect at least 20 milliliters of waste, or a portion of...

  18. 7 CFR 29.426 - Collection of pesticide test samples.

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... 7 Agriculture 2 2013-01-01 2013-01-01 false Collection of pesticide test samples. 29.426 Section... CONTAINER REGULATIONS TOBACCO INSPECTION Regulations Miscellaneous § 29.426 Collection of pesticide test samples. Any lot of tobacco not certified by the importer as being free of prohibited pesticide residues...

  19. 7 CFR 29.426 - Collection of pesticide test samples.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... 7 Agriculture 2 2011-01-01 2011-01-01 false Collection of pesticide test samples. 29.426 Section... CONTAINER REGULATIONS TOBACCO INSPECTION Regulations Miscellaneous § 29.426 Collection of pesticide test samples. Any lot of tobacco not certified by the importer as being free of prohibited pesticide residues...

  20. 7 CFR 29.426 - Collection of pesticide test samples.

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... 7 Agriculture 2 2012-01-01 2012-01-01 false Collection of pesticide test samples. 29.426 Section... CONTAINER REGULATIONS TOBACCO INSPECTION Regulations Miscellaneous § 29.426 Collection of pesticide test samples. Any lot of tobacco not certified by the importer as being free of prohibited pesticide residues...

  1. 7 CFR 29.426 - Collection of pesticide test samples.

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... 7 Agriculture 2 2014-01-01 2014-01-01 false Collection of pesticide test samples. 29.426 Section... CONTAINER REGULATIONS TOBACCO INSPECTION Regulations Miscellaneous § 29.426 Collection of pesticide test samples. Any lot of tobacco not certified by the importer as being free of prohibited pesticide residues...

  2. 7 CFR 29.426 - Collection of pesticide test samples.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... 7 Agriculture 2 2010-01-01 2010-01-01 false Collection of pesticide test samples. 29.426 Section... CONTAINER REGULATIONS TOBACCO INSPECTION Regulations Miscellaneous § 29.426 Collection of pesticide test samples. Any lot of tobacco not certified by the importer as being free of prohibited pesticide residues...

  3. 40 CFR 1065.545 - Validation of proportional flow control for batch sampling.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... 40 Protection of Environment 34 2013-07-01 2013-07-01 false Validation of proportional flow control for batch sampling. 1065.545 Section 1065.545 Protection of Environment ENVIRONMENTAL PROTECTION... Specified Duty Cycles § 1065.545 Validation of proportional flow control for batch sampling. For any...

  4. 40 CFR 1065.545 - Validation of proportional flow control for batch sampling.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... 40 Protection of Environment 34 2012-07-01 2012-07-01 false Validation of proportional flow control for batch sampling. 1065.545 Section 1065.545 Protection of Environment ENVIRONMENTAL PROTECTION... Specified Duty Cycles § 1065.545 Validation of proportional flow control for batch sampling. For any...

  5. 40 CFR 1065.545 - Validation of proportional flow control for batch sampling.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... 40 Protection of Environment 33 2011-07-01 2011-07-01 false Validation of proportional flow control for batch sampling. 1065.545 Section 1065.545 Protection of Environment ENVIRONMENTAL PROTECTION... Specified Duty Cycles § 1065.545 Validation of proportional flow control for batch sampling. For any...

  6. A perception and manipulation system for collecting rock samples

    NASA Technical Reports Server (NTRS)

    Choi, T.; Delingette, H.; Deluise, M.; Hsin, Y.; Hebert, M.; Ikeuchi, Katsushi

    1991-01-01

    An important part of a planetary exploration mission is to collect and analyze surface samples. As part of the Carnegie Mellon University Ambler Project, researchers are investigating techniques for collecting samples using a robot arm and a range sensor. The aim of this work is to make the sample collection operation fully autonomous. Described here are the components of the experimental system, including a perception module that extracts objects of interest from range images and produces models of their shapes, and a manipulation module that enables the system to pick up the objects identified by the perception module. The system was tested on a small testbed using natural terrain.

  7. The Resilience Scale for Adults: Construct Validity and Measurement in a Belgian Sample

    ERIC Educational Resources Information Center

    Hjemdal, Odin; Friborg, Oddgeir; Braun, Stephanie; Kempenaers, Chantal; Linkowski, Paul; Fossion, Pierre

    2011-01-01

    The Resilience Scale for Adults (RSA) was developed and has been extensively validated in Norwegian samples. The purpose of this study was to explore the construct validity of the Resilience Scale for Adults in a French-speaking Belgian sample and test measurement invariance between the Belgian and a Norwegian sample. A Belgian student sample (N =…

  8. Self-Collected versus Clinician-Collected Sampling for Chlamydia and Gonorrhea Screening: A Systemic Review and Meta-Analysis

    PubMed Central

    Lunny, Carole; Taylor, Darlene; Hoang, Linda; Wong, Tom; Gilbert, Mark; Lester, Richard; Krajden, Mel; Ogilvie, Gina

    2015-01-01

    Background The increases in STI rates since the late 1990s in Canada have occurred despite widespread primary care and targeted public health programs and in the setting of universal health care. More innovative interventions are required that would eliminate barriers to STI testing such as internet-based or mail-in home and community service testing for patients that are hard to reach, who refuse to go for clinician-based testing, or who decline an examination. Jurisdictions such as New Zealand and some American states currently use self-collected sampling, but without the required evidence to determine whether self-collected specimens are as accurate as clinician-collected specimens in terms of chlamydia and gonorrhea diagnostic accuracy. The objective of the review is to compare self-collected vaginal, urine, pharyngeal and rectal samples to our reference standard - clinician-collected cervical, urethral, pharyngeal and rectal sampling techniques to identify a positive specimen using nucleic acid amplification test assays. Methods The hierarchical summary receiver operating characteristic and the fixed effect models were used to assess the accuracy of comparable specimens that were collected by patients compared to clinicians. Sensitivity and specificity estimates with 95% confidence intervals (CI) were reported as our main outcome measures. Findings We included 21 studies based on over 6100 paired samples. Fourteen included studies examined chlamydia only, 6 compared both gonorrhea and chlamydia separately in the same study, and one examined gonorrhea. The six chlamydia studies comparing self-collection by vaginal swab to a clinician-collected cervical swab had the highest sensitivity (92%, 95% CI 87-95) and specificity (98%, 95% CI 97-99), compared to other specimen-types (urine/urethra or urine/cervix). Six studies compared urine self-samples to urethra clinician-collected samples in males and produced a sensitivity of 88% (95% CI 83-93) and a specificity of

  9. Acceptability of self-collected versus provider-collected sampling for HPV DNA testing among women in rural El Salvador.

    PubMed

    Rosenbaum, Alan J; Gage, Julia C; Alfaro, Karla M; Ditzian, Lauren R; Maza, Mauricio; Scarinci, Isabel C; Felix, Juan C; Castle, Philip E; Villalta, Sofia; Miranda, Esmeralda; Cremer, Miriam L

    2014-08-01

    To determine the acceptability of self-collected versus provider-collected sampling among women participating in public sector HPV-based cervical cancer screening in El Salvador. Two thousand women aged 30-49 years underwent self-collected and provider-collected sampling with careHPV between October 2012 and March 2013 (Qiagen, Gaithersburg, MD, USA). After sample collection, a random sample of women (n=518) were asked about their experience. Participants were questioned regarding sampling method preference, previous cervical cancer screening, HPV and cervical cancer knowledge, HPV risk factors, and demographic information. All 518 women approached to participate in this questionnaire study agreed and were enrolled, 27.8% (142 of 511 responding) of whom had not received cervical cancer screening within the past 3 years and were considered under-screened. Overall, 38.8% (n=201) preferred self-collection and 31.9% (n=165) preferred provider collection. Self-collection preference was associated with prior tubal ligation, HPV knowledge, future self-sampling preference, and future home-screening preference (P<0.05). Reasons for self-collection preference included privacy/embarrassment, ease, and less pain; reasons cited for provider-collection preference were result accuracy and provider knowledge/experience. Self-sampling was found to be acceptable, therefore screening programs could consider offering this option either in the clinic or at home. Self-sampling at home may increase coverage in low-resource countries and reduce the burden that screening places upon clinical infrastructure. Copyright © 2014 International Federation of Gynecology and Obstetrics. All rights reserved.

  10. Evaluation of standard methods for collecting and processing fuel moisture samples

    Treesearch

    Sally M. Haase; José Sánchez; David R. Weise

    2016-01-01

    A variety of techniques for collecting and processing samples to determine moisture content of wildland fuels in support of fire management activities were evaluated. The effects of using a chainsaw or handsaw to collect samples of largediameter wood, containers for storing and transporting collected samples, and quick-response ovens for estimating moisture content...

  11. [Systematic review of the validity of urine cultures collected by sterile perineal bags].

    PubMed

    Ochoa Sangrador, C; Pascual Terrazas, A

    2016-02-01

    The perineal adhesive bag is the most used method in our country for urine culture collection in infants, despite having a high risk of contamination and false-positive results. We aim to quantify both types of risks through a systematic review. Search updated in May 2014 in PUBMED, SCOPUS (includes EMBASE), IBECS; CINAHL, LILACS AND CUIDEN, without language or time limits. Percentages of contaminated urines, false positives, sensitivity and specificity (with respect to catheterization or bladder puncture) were recorded. A total of 21 studies of medium quality (7,659 samples) were selected. The pooled percentage of contaminated urines was 46.6% (15 studies; 6856 samples; 95% confidence interval [95% CI]: 35.6 to 57.8%; I(2): 97.3%). The pooled percentage of false positives was 61.1% (12 studies; 575 samples; 95% CI: 37.9 to 82.2%; I(2): 96.2%). Sensitivity (88%; 95% CI: 81-93%; I(2): 55.2%), and specificity (82%; 95% CI: 75-89%; I(2): 41.3%) were estimated in five studies, but without including contaminated urines. The perineal adhesive bag is not a valid enough method for urine culture collection, because almost half are contaminated and, if they are positive, two out of three are false. Although these estimates are imprecise, because of their great heterogeneity, they should be considered when choosing the method of urine collection. The estimates of sensitivity and specificity are not applicable because they do not take into account the risk of contamination. Copyright © 2015 Asociación Española de Pediatría. Published by Elsevier España, S.L.U. All rights reserved.

  12. Development and Validation of a Questionnaire on Breastfeeding Intentions, Attitudes and Knowledge of a Sample of Croatian Secondary-School Students.

    PubMed

    Čatipović, Marija; Marković, Martina; Grgurić, Josip

    2018-04-27

    Validating a questionnaire/instrument before proceeding to the field for data collection is important. An 18-item breastfeeding intention, 39-item attitude and 44-item knowledge questionnaire was validated in a Croatian sample of secondary-school students ( N = 277). For the intentions, principal component analysis (PCA) yielded a four-factor solution with 8 items explaining 68.3% of the total variance. Cronbach’s alpha (0.71) indicated satisfactory internal consistency. For the attitudes, PCA showed a seven-factor structure with 33 items explaining 58.41% of total variance. Cronbach’s alpha (0.87) indicated good internal consistency. There were 13 knowledge questions that were retained after item analysis, showing good internal consistency (KR20 = 0.83). In terms of criterion validity, the questionnaire differentiated between students who received breastfeeding education compared to students who were not educated in breastfeeding. Correlations between intentions and attitudes (r = 0.49), intentions and knowledge (r = 0.29), and attitudes and knowledge (r = 0.38) confirmed concurrent validity. The final instrument is reliable and valid for data collection on breastfeeding. Therefore, the instrument is recommended for evaluation of breastfeeding education programs aimed at upper-grade elementary and secondary school students.

  13. The UK Biobank sample handling and storage protocol for the collection, processing and archiving of human blood and urine.

    PubMed

    Elliott, Paul; Peakman, Tim C

    2008-04-01

    UK Biobank is a large prospective study in the UK to investigate the role of genetic factors, environmental exposures and lifestyle in the causes of major diseases of late and middle age. Extensive data and biological samples are being collected from 500,000 participants aged between 40 and 69 years. The biological samples that are collected and how they are processed and stored will have a major impact on the future scientific usefulness of the UK Biobank resource. The aim of the UK Biobank sample handling and storage protocol is to specify methods for the collection and storage of participant samples that give maximum scientific return within the available budget. Processing or storage methods that, as far as can be predicted, will preclude current or future assays have been avoided. The protocol was developed through a review of the literature on sample handling and processing, wide consultation within the academic community and peer review. Protocol development addressed which samples should be collected, how and when they should be processed and how the processed samples should be stored to ensure their long-term integrity. The recommended protocol was extensively tested in a series of validation studies. UK Biobank collects about 45 ml blood and 9 ml of urine with minimal local processing from each participant using the vacutainer system. A variety of preservatives, anti-coagulants and clot accelerators is used appropriate to the expected end use of the samples. Collection of other material (hair, nails, saliva and faeces) was also considered but rejected for the full cohort. Blood and urine samples from participants are transported overnight by commercial courier to a central laboratory where they are processed and aliquots of urine, plasma, serum, white cells and red cells stored in ultra-low temperature archives. Aliquots of whole blood are also stored for potential future production of immortalized cell lines. A standard panel of haematology assays is

  14. Urine sampling and collection system optimization and testing

    NASA Technical Reports Server (NTRS)

    Fogal, G. L.; Geating, J. A.; Koesterer, M. G.

    1975-01-01

    A Urine Sampling and Collection System (USCS) engineering model was developed to provide for the automatic collection, volume sensing and sampling of urine from each micturition. The purpose of the engineering model was to demonstrate verification of the system concept. The objective of the optimization and testing program was to update the engineering model, to provide additional performance features and to conduct system testing to determine operational problems. Optimization tasks were defined as modifications to minimize system fluid residual and addition of thermoelectric cooling.

  15. CTEPP STANDARD OPERATING PROCEDURE FOR COLLECTION OF URINE SAMPLES (SOP-2.14)

    EPA Science Inventory

    This SOP describes the method for collecting urine samples from the study participants (children and their primary caregivers). Urine samples will be approximate 48-hr collections, collected as spot urine samples accumulated over the 48-hr sampling period. If the household or da...

  16. Development and Preliminary Validation of the Collective Efficacy Questionnaire for Sports

    ERIC Educational Resources Information Center

    Short, Sandra E.; Sullivan, Philip; Feltz, Deborah L.

    2005-01-01

    This study presents the development and preliminary validation of the Collective Efficacy Questionnaire for Sports (CEQS). The study was conducted in 3 phases. In Phase 1, a 42-item questionnaire was developed and tested with 271 college-aged student-athletes. An exploratory factor analysis revealed 5 collective efficacy factors with 27 items…

  17. Techniques for Down-Sampling a Measured Surface Height Map for Model Validation

    NASA Technical Reports Server (NTRS)

    Sidick, Erkin

    2012-01-01

    This software allows one to down-sample a measured surface map for model validation, not only without introducing any re-sampling errors, but also eliminating the existing measurement noise and measurement errors. The software tool of the current two new techniques can be used in all optical model validation processes involving large space optical surfaces

  18. Curating NASA's Past, Present, and Future Astromaterial Sample Collections

    NASA Technical Reports Server (NTRS)

    Zeigler, R. A.; Allton, J. H.; Evans, C. A.; Fries, M. D.; McCubbin, F. M.; Nakamura-Messenger, K.; Righter, K.; Zolensky, M.; Stansbery, E. K.

    2016-01-01

    The Astromaterials Acquisition and Curation Office at NASA Johnson Space Center (hereafter JSC curation) is responsible for curating all of NASA's extraterrestrial samples. JSC presently curates 9 different astromaterials collections in seven different clean-room suites: (1) Apollo Samples (ISO (International Standards Organization) class 6 + 7); (2) Antarctic Meteorites (ISO 6 + 7); (3) Cosmic Dust Particles (ISO 5); (4) Microparticle Impact Collection (ISO 7; formerly called Space-Exposed Hardware); (5) Genesis Solar Wind Atoms (ISO 4); (6) Stardust Comet Particles (ISO 5); (7) Stardust Interstellar Particles (ISO 5); (8) Hayabusa Asteroid Particles (ISO 5); (9) OSIRIS-REx Spacecraft Coupons and Witness Plates (ISO 7). Additional cleanrooms are currently being planned to house samples from two new collections, Hayabusa 2 (2021) and OSIRIS-REx (2023). In addition to the labs that house the samples, we maintain a wide variety of infra-structure facilities required to support the clean rooms: HEPA-filtered air-handling systems, ultrapure dry gaseous nitrogen systems, an ultrapure water system, and cleaning facilities to provide clean tools and equipment for the labs. We also have sample preparation facilities for making thin sections, microtome sections, and even focused ion-beam sections. We routinely monitor the cleanliness of our clean rooms and infrastructure systems, including measurements of inorganic or organic contamination, weekly airborne particle counts, compositional and isotopic monitoring of liquid N2 deliveries, and daily UPW system monitoring. In addition to the physical maintenance of the samples, we track within our databases the current and ever changing characteristics (weight, location, etc.) of more than 250,000 individually numbered samples across our various collections, as well as more than 100,000 images, and countless "analog" records that record the sample processing records of each individual sample. JSC Curation is co-located with JSC

  19. Characterization and validation of sampling and analytical methods for mycotoxins in workplace air.

    PubMed

    Jargot, Danièle; Melin, Sandrine

    2013-03-01

    Mycotoxins are produced by certain plant or foodstuff moulds under growing, transport or storage conditions. They are toxic for humans and animals, some are carcinogenic. Methods to monitor occupational exposure to seven of the most frequently occurring airborne mycotoxins have been characterized and validated. Experimental aerosols have been generated from naturally contaminated particles for sampler evaluation. Air samples were collected on foam pads, using the CIP 10 personal aerosol sampler with its inhalable health-related aerosol fraction selector. The samples were subsequently solvent extracted from the sampling media, cleaned using immunoaffinity (IA) columns and analyzed by liquid chromatography with fluorescence detection. Ochratoxin A (OTA) or fumonisin and aflatoxin derivatives were detected and quantified. The quantification limits were 0.015 ng m(-3) OTA, 1 ng m(-3) fumonisins or 0.5 pg m(-3) aflatoxins, with a minimum dust concentration level of 1 mg m(-3) and a 4800 L air volume sampling. The methods were successfully applied to field measurements, which confirmed that workers could be exposed when handling contaminated materials. It was observed that airborne particles may be more contaminated than the bulk material itself. The validated methods have measuring ranges fully adapted to the concentrations found in the workplace. Their performance meets the general requirements laid down for chemical agent measurement procedures, with an expanded uncertainty less than 50% for most mycotoxins. The analytical uncertainty, comprised between 14 and 24%, was quite satisfactory given the low mycotoxin amounts, when compared to the food benchmarks. The methods are now user-friendly enough to be adopted for personal workplace sampling. They will later allow for mycotoxin occupational risk assessment, as only very few quantitative data have been available till now.

  20. Random sampling and validation of covariance matrices of resonance parameters

    NASA Astrophysics Data System (ADS)

    Plevnik, Lucijan; Zerovnik, Gašper

    2017-09-01

    Analytically exact methods for random sampling of arbitrary correlated parameters are presented. Emphasis is given on one hand on the possible inconsistencies in the covariance data, concentrating on the positive semi-definiteness and consistent sampling of correlated inherently positive parameters, and on the other hand on optimization of the implementation of the methods itself. The methods have been applied in the program ENDSAM, written in the Fortran language, which from a file from a nuclear data library of a chosen isotope in ENDF-6 format produces an arbitrary number of new files in ENDF-6 format which contain values of random samples of resonance parameters (in accordance with corresponding covariance matrices) in places of original values. The source code for the program ENDSAM is available from the OECD/NEA Data Bank. The program works in the following steps: reads resonance parameters and their covariance data from nuclear data library, checks whether the covariance data is consistent, and produces random samples of resonance parameters. The code has been validated with both realistic and artificial data to show that the produced samples are statistically consistent. Additionally, the code was used to validate covariance data in existing nuclear data libraries. A list of inconsistencies, observed in covariance data of resonance parameters in ENDF-VII.1, JEFF-3.2 and JENDL-4.0 is presented. For now, the work has been limited to resonance parameters, however the methods presented are general and can in principle be extended to sampling and validation of any nuclear data.

  1. Asteroid Redirect Mission: EVA and Sample Collection

    NASA Technical Reports Server (NTRS)

    Abell, Paul; Stich, Steve

    2015-01-01

    Asteroid Redirect Mission (ARM) Overview (1) Notional Development Schedule, (2) ARV Crewed Mission Accommodations; Asteroid Redirect Crewed Mission (ARCM) Mission Summary; ARCM Accomplishments; Sample collection/curation plan (1) CAPTEM Requirements; SBAG Engagement Plan

  2. Stepping Outside the Normed Sample: Implications for Validity

    ERIC Educational Resources Information Center

    Hays, Danica G.; Wood, Chris

    2017-01-01

    We present considerations for validity when a population outside of a normed sample is assessed and those data are interpreted. Using a career group counseling example exploring life satisfaction changes as evidenced by the Quality of Life Inventory (Frisch, 1994), we showcase qualitative and quantitative approaches to explore how normative data…

  3. Collecting the data but missing the point: validity of hand hygiene audit data.

    PubMed

    Jeanes, A; Coen, P G; Wilson, A P; Drey, N S; Gould, D J

    2015-06-01

    Monitoring of hand hygiene compliance (HHC) by observation has been used in healthcare for more than a decade to provide assurance of infection control practice. The validity of this information is rarely tested. To examine the process and validity of collecting and reporting HHC data based on direct observation of compliance. Five years of HHC data routinely collected in one large National Health Service hospital trust were examined. The data collection process was reviewed by survey and interview of the auditors. HHC data collected for other research purposes undertaken during this period were compared with the organizational data set. After an initial increase, the reported HHC remained unchanged close to its intended target throughout this period. Examination of the data collection process revealed changes, including local interpretations of the data collection system, which invalidated the results. A minority of auditors had received formal training in observation and feedback of results. Whereas observation of HHC is the current gold standard, unless data collection definitions and methods are unambiguous, published, carefully supervised, and regularly monitored, variations may occur which affect the validity of the data. If the purpose of HHC monitoring is to improve practice and minimize transmission of infection, then a focus on progressively improving performance rather than on achieving a target may offer greater opportunities to achieve this. Copyright © 2015 The Healthcare Infection Society. Published by Elsevier Ltd. All rights reserved.

  4. Experimental Validation Plan for the Xolotl Plasma-Facing Component Simulator Using Tokamak Sample Exposures

    NASA Astrophysics Data System (ADS)

    Chan, V. S.; Wong, C. P. C.; McLean, A. G.; Luo, G. N.; Wirth, B. D.

    2013-10-01

    The Xolotl code under development by PSI-SciDAC will enhance predictive modeling capability of plasma-facing materials under burning plasma conditions. The availability and application of experimental data to compare to code-calculated observables are key requirements to validate the breadth and content of physics included in the model and ultimately gain confidence in its results. A dedicated effort has been in progress to collect and organize a) a database of relevant experiments and their publications as previously carried out at sample exposure facilities in US and Asian tokamaks (e.g., DIII-D DiMES, and EAST MAPES), b) diagnostic and surface analysis capabilities available at each device, and c) requirements for future experiments with code validation in mind. The content of this evolving database will serve as a significant resource for the plasma-material interaction (PMI) community. Work supported in part by the US Department of Energy under GA-DE-SC0008698, DE-AC52-07NA27344 and DE-AC05-00OR22725.

  5. Analytical method validation for the determination of 2,3,3,3-tetrafluoropropene in air samples using gas chromatography with flame ionization detection.

    PubMed

    Mawn, Michael P; Kurtz, Kristine; Stahl, Deborah; Chalfant, Richard L; Koban, Mary E; Dawson, Barbara J

    2013-01-01

    A new low global warming refrigerant, 2,3,3,3-tetrafluoro propene, or HFO-1234yf, has been successfully evaluated for automotive air conditioning, and is also being evaluated for stationary refrigeration and air conditioning systems. Due to the advantageous environmental properties of HFO-1234yf versus HFC-134a, coupled with its similar physical properties and system performance, HFO-1234yf is also being evaluated to replace HFC-134a in refrigeration applications where neat HFC-134a is currently used. This study reports on the development and validation of a sampling and analytical method for the determination of HFO-1234yf in air. Different collection media were screened for desorption and simulated sampling efficiency with three-section (350/350/350 mg) Anasorb CSC showing the best results. Therefore, air samples were collected using two 3-section Anasorb CSC sorbent tubes in series at 0.02 L/min for up to 8 hr for sample volumes of up to 9.6 L. The sorbent tubes were extracted in methylene chloride, and analyzed by gas chromatography with flame ionization detection. The method was validated from 0.1× to 20× the target level of 0.5 ppm (2.3 mg/m(3)) for a 9.6 L air volume. Desorption efficiencies for HFO-1234yf were 88 to 109% for all replicates over the validation range with a mean overall recovery of 93%. Simulated sampling efficiencies ranged from 87 to 104% with a mean of 94%. No migration or breakthrough to the back tube was observed under the sampling conditions evaluated. HFO-1234yf samples showed acceptable storage stability on Anasorb CSC sorbent up to a period of 30 days when stored under ambient, refrigerated, or frozen temperature conditions.

  6. Development and Validation of a Questionnaire on Breastfeeding Intentions, Attitudes and Knowledge of a Sample of Croatian Secondary-School Students

    PubMed Central

    Marković, Martina; Grgurić, Josip

    2018-01-01

    Background: Validating a questionnaire/instrument before proceeding to the field for data collection is important. Methods: An 18-item breastfeeding intention, 39-item attitude and 44-item knowledge questionnaire was validated in a Croatian sample of secondary-school students (N = 277). Results: For the intentions, principal component analysis (PCA) yielded a four-factor solution with 8 items explaining 68.3% of the total variance. Cronbach’s alpha (0.71) indicated satisfactory internal consistency. For the attitudes, PCA showed a seven-factor structure with 33 items explaining 58.41% of total variance. Cronbach’s alpha (0.87) indicated good internal consistency. There were 13 knowledge questions that were retained after item analysis, showing good internal consistency (KR20 = 0.83). In terms of criterion validity, the questionnaire differentiated between students who received breastfeeding education compared to students who were not educated in breastfeeding. Correlations between intentions and attitudes (r = 0.49), intentions and knowledge (r = 0.29), and attitudes and knowledge (r = 0.38) confirmed concurrent validity. Conclusions: The final instrument is reliable and valid for data collection on breastfeeding. Therefore, the instrument is recommended for evaluation of breastfeeding education programs aimed at upper-grade elementary and secondary school students. PMID:29702616

  7. Protocol for collecting eDNA samples from streams [Version 2.3

    Treesearch

    K. J. Carim; T. Wilcox; M. K. Young; K. S. McKelvey; M. K. Schwartz

    2015-01-01

    Throughout the 2014 field season, we had over two dozen biologist throughout the western US collect over 300 samples for eDNA analysis with paired controls. Control samples were collected by filtering 0.5 L of distilled water. No samples had any evidence of field contamination. This method of sampling verifies the cleanliness of the field equipment, as well as the...

  8. Comparison of Collection Methods for Fecal Samples in Microbiome Studies

    PubMed Central

    Vogtmann, Emily; Chen, Jun; Amir, Amnon; Shi, Jianxin; Abnet, Christian C.; Nelson, Heidi; Knight, Rob; Chia, Nicholas; Sinha, Rashmi

    2017-01-01

    Prospective cohort studies are needed to assess the relationship between the fecal microbiome and human health and disease. To evaluate fecal collection methods, we determined technical reproducibility, stability at ambient temperature, and accuracy of 5 fecal collection methods (no additive, 95% ethanol, RNAlater Stabilization Solution, fecal occult blood test cards, and fecal immunochemical test tubes). Fifty-two healthy volunteers provided fecal samples at the Mayo Clinic in Rochester, Minnesota, in 2014. One set from each sample collection method was frozen immediately, and a second set was incubated at room temperature for 96 hours and then frozen. Intraclass correlation coefficients (ICCs) were calculated for the relative abundance of 3 phyla, 2 alpha diversity metrics, and 4 beta diversity metrics. Technical reproducibility was high, with ICCs for duplicate fecal samples between 0.64 and 1.00. Stability for most methods was generally high, although the ICCs were below 0.60 for 95% ethanol in metrics that were more sensitive to relative abundance. When compared with fecal samples that were frozen immediately, the ICCs were below 0.60 for the metrics that were sensitive to relative abundance; however, the remaining 2 alpha diversity and 3 beta diversity metrics were all relatively accurate, with ICCs above 0.60. In conclusion, all fecal sample collection methods appear relatively reproducible, stable, and accurate. Future studies could use these collection methods for microbiome analyses. PMID:27986704

  9. Collection of Calibration and Validation Data for An Airport Landside Dynamic Simulation Model

    DOT National Transportation Integrated Search

    1980-04-01

    The report summarizes the airport data collection procedures employed to obtain the necessary calibration and validation information. The preparation for the data collection effort is explained. A description is presented of the initial work tasks, w...

  10. Validation of a High Sampling Rate Inertial Measurement Unit for Acceleration During Running.

    PubMed

    Provot, Thomas; Chiementin, Xavier; Oudin, Emeric; Bolaers, Fabrice; Murer, Sébastien

    2017-08-25

    The musculo-skeletal response of athletes to various activities during training exercises has become a critical issue in order to optimize their performance and minimize injuries. However, dynamic and kinematic measures of an athlete's activity are generally limited by constraints in data collection and technology. Thus, the choice of reliable and accurate sensors is crucial for gathering data in indoor and outdoor conditions. The aim of this study is to validate the use of the accelerometer of a high sampling rate ( 1344 Hz ) Inertial Measurement Unit (IMU) in the frame of running activities. To this end, two validation protocols are imposed: a classical one on a shaker, followed by another one during running, the IMU being attached to a test subject. For each protocol, the response of the IMU Accelerometer (IMUA) is compared to a calibrated industrial accelerometer, considered as the gold standard for dynamic and kinematic data collection. The repeatability, impact of signal frequency and amplitude (on shaker) as well as the influence of speed (while running) are investigated. Results reveal that the IMUA exhibits good repeatability. Coefficient of Variation CV is 1 % 8.58 ± 0.06 m / s 2 on the shaker and 3 % 26.65 ± 0.69 m / s 2 while running. However, the shaker test shows that the IMUA is affected by the signal frequency (error exceeds 10 % beyond 80 Hz ), an observation confirmed by the running test. Nevertheless, the IMUA provides a reliable measure in the range 0-100 Hz, i.e., the most relevant part in the energy spectrum over the range 0-150 Hz during running. In our view, these findings emphasize the validity of IMUs for the measurement of acceleration during running.

  11. A simple technic for repeated collection of blood samples from mice.

    PubMed

    Stoltz, D R; Bendall, R D

    1975-06-01

    A device for repeated collection of small blood samples from mice was constructed from a plastic syringe. Blood was collected into a 3.33 lambda capillary tube. Bleeding was stopped by a hemostat made from a rubber stopper. This technic allows easy collection of approximately 20 serial samples within an 8-hr period.

  12. Validation and Evaluation of Army Aviation Collective Performance Measures

    DTIC Science & Technology

    2014-01-01

    Research Report 1972 Validation and Evaluation of Army Aviation Collective Performance Measures Martin L. Bink U.S. Army...United States Army Research Institute for the Behavioral and Social Sciences Approved for public release; distribution is unlimited. U.S. Army...Research Institute for the Behavioral and Social Sciences Department of the Army Deputy Chief of Staff, G1 Authorized and approved for

  13. Pesticide-sampling equipment, sample-collection and processing procedures, and water-quality data at Chicod Creek, North Carolina, 1992

    USGS Publications Warehouse

    Manning, T.K.; Smith, K.E.; Wood, C.D.; Williams, J.B.

    1994-01-01

    Water-quality samples were collected from Chicod Creek in the Coastal Plain Province of North Carolina during the summer of 1992 as part of the U.S. Geological Survey's National Water-Quality Assessment Program. Chicod Creek is in the Albemarle-Pamlico drainage area, one of four study units designated to test equipment and procedures for collecting and processing samples for the solid-phase extraction of selected pesticides, The equipment and procedures were used to isolate 47 pesticides, including organonitrogen, carbamate, organochlorine, organophosphate, and other compounds, targeted to be analyzed by gas chromatography/mass spectrometry. Sample-collection and processing equipment equipment cleaning and set-up procedures, methods pertaining to collecting, splitting, and solid-phase extraction of samples, and water-quality data resulting from the field test are presented in this report Most problems encountered during this intensive sampling exercise were operational difficulties relating to equipment used to process samples.

  14. A content validated questionnaire for assessment of self reported venous blood sampling practices

    PubMed Central

    2012-01-01

    Background Venous blood sampling is a common procedure in health care. It is strictly regulated by national and international guidelines. Deviations from guidelines due to human mistakes can cause patient harm. Validated questionnaires for health care personnel can be used to assess preventable "near misses"--i.e. potential errors and nonconformities during venous blood sampling practices that could transform into adverse events. However, no validated questionnaire that assesses nonconformities in venous blood sampling has previously been presented. The aim was to test a recently developed questionnaire in self reported venous blood sampling practices for validity and reliability. Findings We developed a questionnaire to assess deviations from best practices during venous blood sampling. The questionnaire contained questions about patient identification, test request management, test tube labeling, test tube handling, information search procedures and frequencies of error reporting. For content validity, the questionnaire was confirmed by experts on questionnaires and venous blood sampling. For reliability, test-retest statistics were used on the questionnaire answered twice. The final venous blood sampling questionnaire included 19 questions out of which 9 had in total 34 underlying items. It was found to have content validity. The test-retest analysis demonstrated that the items were generally stable. In total, 82% of the items fulfilled the reliability acceptance criteria. Conclusions The questionnaire could be used for assessment of "near miss" practices that could jeopardize patient safety and gives several benefits instead of assessing rare adverse events only. The higher frequencies of "near miss" practices allows for quantitative analysis of the effect of corrective interventions and to benchmark preanalytical quality not only at the laboratory/hospital level but also at the health care unit/hospital ward. PMID:22260505

  15. A content validated questionnaire for assessment of self reported venous blood sampling practices.

    PubMed

    Bölenius, Karin; Brulin, Christine; Grankvist, Kjell; Lindkvist, Marie; Söderberg, Johan

    2012-01-19

    Venous blood sampling is a common procedure in health care. It is strictly regulated by national and international guidelines. Deviations from guidelines due to human mistakes can cause patient harm. Validated questionnaires for health care personnel can be used to assess preventable "near misses"--i.e. potential errors and nonconformities during venous blood sampling practices that could transform into adverse events. However, no validated questionnaire that assesses nonconformities in venous blood sampling has previously been presented. The aim was to test a recently developed questionnaire in self reported venous blood sampling practices for validity and reliability. We developed a questionnaire to assess deviations from best practices during venous blood sampling. The questionnaire contained questions about patient identification, test request management, test tube labeling, test tube handling, information search procedures and frequencies of error reporting. For content validity, the questionnaire was confirmed by experts on questionnaires and venous blood sampling. For reliability, test-retest statistics were used on the questionnaire answered twice. The final venous blood sampling questionnaire included 19 questions out of which 9 had in total 34 underlying items. It was found to have content validity. The test-retest analysis demonstrated that the items were generally stable. In total, 82% of the items fulfilled the reliability acceptance criteria. The questionnaire could be used for assessment of "near miss" practices that could jeopardize patient safety and gives several benefits instead of assessing rare adverse events only. The higher frequencies of "near miss" practices allows for quantitative analysis of the effect of corrective interventions and to benchmark preanalytical quality not only at the laboratory/hospital level but also at the health care unit/hospital ward.

  16. Factorial validity of the Job Expectations Questionnaire in a sample of Mexican workers.

    PubMed

    Villa-George, Fabiola Itzel; Moreno-Jiménez, Bernardo; Rodríguez-Muñoz, Alfredo; Villalpando Uribe, Jessica

    2011-11-01

    The aim of this study was to examine the factorial validity of the Job Expectations Questionnaire (Cuestionario de Expectativas Laborales CEL) in a sample of Mexican workers. Following a cross validation approach, two samples were used in the study. The first sample consisted of 380 professionals who mainly performed administrative work in the Health Services in Puebla-Mexico. The second sample comprised 400 health professionals from the Hospital de la Mujer in Puebla-Mexico. Exploratory factor analysis yielded a three-factor solution, accounting for 51.8% of the variance. The results of confirmatory factorial analysis indicate that the three-factor model provided the best fit with the data (CFI = .96, GFI = .95, NNFI = .95, RMSEA = .04), maintaining the structure with 12 items. The reliability of the questionnaire and the diverse subscales showed high internal consistency. Significant correlations were found between job expectations and autonomy, vigor, dedication, and absorption, providing evidence of its construct validity. The evaluation of the psychometric qualities confirms this questionnaire as a valid and specific instrument to measure job expectations.

  17. Optimization and validation of sample preparation for metagenomic sequencing of viruses in clinical samples.

    PubMed

    Lewandowska, Dagmara W; Zagordi, Osvaldo; Geissberger, Fabienne-Desirée; Kufner, Verena; Schmutz, Stefan; Böni, Jürg; Metzner, Karin J; Trkola, Alexandra; Huber, Michael

    2017-08-08

    Sequence-specific PCR is the most common approach for virus identification in diagnostic laboratories. However, as specific PCR only detects pre-defined targets, novel virus strains or viruses not included in routine test panels will be missed. Recently, advances in high-throughput sequencing allow for virus-sequence-independent identification of entire virus populations in clinical samples, yet standardized protocols are needed to allow broad application in clinical diagnostics. Here, we describe a comprehensive sample preparation protocol for high-throughput metagenomic virus sequencing using random amplification of total nucleic acids from clinical samples. In order to optimize metagenomic sequencing for application in virus diagnostics, we tested different enrichment and amplification procedures on plasma samples spiked with RNA and DNA viruses. A protocol including filtration, nuclease digestion, and random amplification of RNA and DNA in separate reactions provided the best results, allowing reliable recovery of viral genomes and a good correlation of the relative number of sequencing reads with the virus input. We further validated our method by sequencing a multiplexed viral pathogen reagent containing a range of human viruses from different virus families. Our method proved successful in detecting the majority of the included viruses with high read numbers and compared well to other protocols in the field validated against the same reference reagent. Our sequencing protocol does work not only with plasma but also with other clinical samples such as urine and throat swabs. The workflow for virus metagenomic sequencing that we established proved successful in detecting a variety of viruses in different clinical samples. Our protocol supplements existing virus-specific detection strategies providing opportunities to identify atypical and novel viruses commonly not accounted for in routine diagnostic panels.

  18. Methods for collection and analysis of water samples

    USGS Publications Warehouse

    Rainwater, Frank Hays; Thatcher, Leland Lincoln

    1960-01-01

    This manual contains methods used by the U.S. Geological Survey to collect, preserve, and analyze water samples. Throughout, the emphasis is on obtaining analytical results that accurately describe the chemical composition of the water in situ. Among the topics discussed are selection of sampling sites, frequency of sampling, field equipment, preservatives and fixatives, analytical techniques of water analysis, and instruments. Seventy-seven laboratory and field procedures are given for determining fifty-three water properties.

  19. Astronaut Harrison Schmitt collects lunar rake samples during EVA

    NASA Image and Video Library

    1972-12-11

    AS17-134-20425 (11 Dec. 1972) --- Scientist-astronaut Harrison H. Schmitt, lunar module pilot, collects lunar rake samples at Station 1 during the first Apollo 17 extravehicular activity (EVA) at the Taurus-Littrow landing site. This picture was taken by astronaut Eugene Cernan, commander. The lunar rake, an Apollo lunar geology hand tool, is used to collect discrete samples of rocks and rock chips ranging in size from one-half inch (1.3 centimeter) to one inch (2.5 centimeter).

  20. Sample size determination for disease prevalence studies with partially validated data.

    PubMed

    Qiu, Shi-Fang; Poon, Wai-Yin; Tang, Man-Lai

    2016-02-01

    Disease prevalence is an important topic in medical research, and its study is based on data that are obtained by classifying subjects according to whether a disease has been contracted. Classification can be conducted with high-cost gold standard tests or low-cost screening tests, but the latter are subject to the misclassification of subjects. As a compromise between the two, many research studies use partially validated datasets in which all data points are classified by fallible tests, and some of the data points are validated in the sense that they are also classified by the completely accurate gold-standard test. In this article, we investigate the determination of sample sizes for disease prevalence studies with partially validated data. We use two approaches. The first is to find sample sizes that can achieve a pre-specified power of a statistical test at a chosen significance level, and the second is to find sample sizes that can control the width of a confidence interval with a pre-specified confidence level. Empirical studies have been conducted to demonstrate the performance of various testing procedures with the proposed sample sizes. The applicability of the proposed methods are illustrated by a real-data example. © The Author(s) 2012.

  1. Lead Concentration Levels in Water Samples Collected in Alameda County, CA

    NASA Astrophysics Data System (ADS)

    Sethy, D.; Hoang, R.; Yu, I.; Hernandez, N.; Fang, K.; Zhang, W.; Li, J.; Munui, K. N.; Sot, R.; Luong, K.; Bonzo, R.; Sankar, R.; Chiu, D.; Rodriguez, V. A.

    2016-12-01

    The recent health crisis in Flint, Michigan has attracted an amount of interest in other public utilities' water supplies and infrastructure with regards to concerns over the presence of lead. In an effort to begin assessing the potential for a health crisis similar to that experienced in Flynt, during 2016 our team measured lead concentration levels in water samples by collected in Alameda County. More than 12 sites were selected from which samples were collected. These sites included parks, schools, and private residences. At each site 500mL samples were collected and prepared for later analysis. Samples were subjected to an analytical chemistry technique designed to isolate and concentrate lead to detectable levels of 1 part per billion (ppb). All 8 samples yielded detectable levels of lead; all samples were also well below the EPA regulatory 15 ppb. Two samples collected in West Oakland parks were found to have the highest and lowest levels: DeFremery (4 ppb) and Raimondi (1ppb), respectively. Though preliminary in nature, results from this study suggest that further investigations should be undertaken to assess possible lead contamination associated with drinking water sources in Alameda County.

  2. Vascular Blood Collection protocol samples into MELFI

    NASA Image and Video Library

    2011-10-18

    iss029e028495 (10/18/2011) --- Japan Aerospace Exploration Agency astronaut Satoshi Furukawa,Expedition 29 flight engineer,prepares to put samples from the CSA (Canadian Space Agency) Vascular Blood Collection protocol into the MELFI-1 (Minus Eighty Laboratory Freezer for ISS 1) unit.

  3. Sample Collection for the Russian Biodegradatsiya Experiment

    NASA Image and Video Library

    2007-10-01

    ISS015-E-32031 (October 2007) --- Cosmonaut Oleg V. Kotov, Expedition 15 flight engineer representing Russia's Federal Space Agency, uses a Bioproby Kit to collect surface samples for analysis for the Russian Biodegradation experiment in the Zvezda Service Module of the International Space Station.

  4. Astronaut Harrison Schmitt collects lunar rake samples during EVA

    NASA Image and Video Library

    1972-12-11

    AS17-134-20426 (11 Dec. 1972) --- Scientist-astronaut Harrison H. Schmitt collects lunar rake samples at Station 1 during the first Apollo 17 extravehicular activity (EVA) at the Taurus-Littrow landing site. This picture was taken by astronaut Eugene A. Cernan, Apollo 17 commander. Schmitt is the lunar module pilot. The Lunar Rake, an Apollo Lunar Geology Hand Tool, is used to collect discrete samples of rocks and rock chips ranging in size from one-half inch (1.3 cm) to one inch (2.5 cm).

  5. The acceptability and validity of self-collected nasal swabs for detection of influenza virus infection among older adults in Thailand.

    PubMed

    Goyal, Sonal; Prasert, Kriengkrai; Praphasiri, Prabda; Chittaganpitch, Malinee; Waicharoen, Sunthareeya; Ditsungnoen, Darunee; Jaichuang, Siriluk; Lindblade, Kim A

    2017-09-01

    Self-collection of nasal swabs could improve the timeliness of influenza virus detection in older adults. Measure the acceptability, adequacy, timeliness, and validity of self-collected nasal swabs among adults >65 years in Thailand. Our evaluation consisted of two parts: a one-month study among randomly selected, community-dwelling older adults to simulate community-based surveillance for acute respiratory infections (ARI); and a clinic study of older adults with ARI to evaluate the sensitivity and specificity of self-collected nasal swabs for influenza virus infection compared with healthcare worker (HCW)-collected nasal and nasopharyngeal swabs. In the community study, 24% of participants experienced an ARI during the observation period. All (100%) participants with an ARI self-collected nasal swabs within 72 hours of symptom onset of which 92% were considered adequate samples. In the clinic study, 45% of patients with ARI presented within 72 hours of symptom onset. The sensitivity of self-collected nasal swabs for detection of influenza virus infection was 78% (95% CI 40-97) compared to nasopharyngeal and 88% (95% CI 47-100) compared to nasal swabs collected by HCWs. Specificity was 100% (95% CI 97-100) compared to both methods. Self-collection of nasal swabs was found acceptable by 99% of participants in both studies. Self-collection of nasal swabs was acceptable to older adults in Thailand who were able to take adequate samples. Self-collection of nasal swabs may improve the timeliness of sample collection but lower sensitivity will need to be considered. © 2017 The Authors. Influenza and Other Respiratory Viruses Published by John Wiley & Sons Ltd.

  6. Self-collected versus clinician-collected sampling for sexually transmitted infections: a systematic review and meta-analysis protocol.

    PubMed

    Taylor, Darlene; Lunny, Carole; Wong, Tom; Gilbert, Mark; Li, Neville; Lester, Richard; Krajden, Mel; Hoang, Linda; Ogilvie, Gina

    2013-10-10

    Three meta-analyses and one systematic review have been conducted on the question of whether self-collected specimens are as accurate as clinician-collected specimens for STI screening. However, these reviews predate 2007 and did not analyze rectal or pharyngeal collection sites. Currently, there is no consensus on which sampling method is the most effective for the diagnosis of genital chlamydia (CT), gonorrhea (GC) or human papillomavirus (HPV) infection. Our meta-analysis aims to be comprehensive in that it will examine the evidence of whether self-collected vaginal, urine, pharyngeal and rectal specimens provide as accurate a clinical diagnosis as clinician-collected samples (reference standard). Eligible studies include both randomized and non-randomized controlled trials, pre- and post-test designs, and controlled observational studies. The databases that will be searched include the Cochrane Database of Systematic Reviews, Web of Science, Database of Abstracts of Reviews of Effects (DARE), EMBASE and PubMed/Medline. Data will be abstracted independently by two reviewers using a standardized pre-tested data abstraction form. Heterogeneity will be assessed using the Q2 test. Sensitivity and specificity estimates with 95% confidence intervals as well as negative and positive likelihood ratios will be pooled and weighted using random effects meta-analysis, if appropriate. A hierarchical summary receiver operating characteristics curve for self-collected specimens will be generated. This synthesis involves a meta-analysis of self-collected samples (urine, vaginal, pharyngeal and rectal swabs) versus clinician-collected samples for the diagnosis of CT, GC and HPV, the most prevalent STIs. Our systematic review will allow patients, clinicians and researchers to determine the diagnostic accuracy of specimens collected by patients compared to those collected by clinicians in the detection of chlamydia, gonorrhea and HPV.

  7. Collection of biological samples in forensic toxicology.

    PubMed

    Dinis-Oliveira, R J; Carvalho, F; Duarte, J A; Remião, F; Marques, A; Santos, A; Magalhães, T

    2010-09-01

    Forensic toxicology is the study and practice of the application of toxicology to the purposes of the law. The relevance of any finding is determined, in the first instance, by the nature and integrity of the specimen(s) submitted for analysis. This means that there are several specific challenges to select and collect specimens for ante-mortem and post-mortem toxicology investigation. Post-mortem specimens may be numerous and can endow some special difficulties compared to clinical specimens, namely those resulting from autolytic and putrefactive changes. Storage stability is also an important issue to be considered during the pre-analytic phase, since its consideration should facilitate the assessment of sample quality and the analytical result obtained from that sample. The knowledge on degradation mechanisms and methods to increase storage stability may enable the forensic toxicologist to circumvent possible difficulties. Therefore, advantages and limitations of specimen preservation procedures are thoroughfully discussed in this review. Presently, harmonized protocols for sampling in suspected intoxications would have obvious utility. In the present article an overview is given on sampling procedures for routinely collected specimens as well as on alternative specimens that may provide additional information on the route and timing of exposure to a specific xenobiotic. Last, but not least, a discussion on possible bias that can influence the interpretation of toxicological results is provided. This comprehensive review article is intented as a significant help for forensic toxicologists to accomplish their frequently overwhelming mission.

  8. Validity of the MMPI-2-RF (Restructured Form) L-r and K-r Scales in Detecting Underreporting in Clinical and Nonclinical Samples

    ERIC Educational Resources Information Center

    Sellbom, Martin; Bagby, R. Michael

    2008-01-01

    In the current investigation, the authors examined the validity of the L-r and K-r scales on the recently developed Minnesota Multiphasic Personality Inventory-2-Restructured Form (MMPI-2-RF; Y. S. Ben-Porath & A. Tellegen, in press) in measuring underreported response bias. Three archival samples previously collected for examining MMPI-2…

  9. Variability of collagen crosslinks: impact of sample collection period

    NASA Technical Reports Server (NTRS)

    Smith, S. M.; Dillon, E. L.; DeKerlegand, D. E.; Davis-Street, J. E.

    2004-01-01

    Because of the variability of collagen crosslinks, their use as markers for bone resorption is often criticized. We hypothesized that the variability could be reduced by collecting urine for 24 hours (or longer) instead of using single voids, and by not normalizing to creatinine. Urine samples were collected from 22 healthy subjects during two or more 24-hour periods. Each 24-hour pool and each 2nd void of the day were analyzed for N-telopeptide (NTX), pyridinium (PYD), and deoxypyridinoline (DPD) crosslinks. Data were analyzed by using linear regression. For NTX, R2 for the two, 2nd-void samples (n = 38) was 0.55, whereas R2 for the two 24-hour pools was 0.51 or 0.52, expressed per day or per creatinine. For PYD and DPD, R2 for the 2nd-void samples was 0.26 and 0.18, R2 for the 24-hour pools expressed per day was 0.58 and 0.74, and R2 for the 24-hour pools expressed per creatinine was 0.65 and 0.76, respectively. Regression of the 2nd void and the corresponding 24-hour pool, expressed per day, yielded R2 = 0.19, 0.19, and 0.08, for NTX, PYD, and DPD, respectively (n = 76 each). For the 2nd-void sample and its corresponding 24-hour pool, expressed per creatinine, R2 = 0.24, 0.33, and 0.08, respectively. In a separate study, the coefficient of variation for NTX was reduced (P < 0.05) when data from more than one 24-hour collection were combined. Thus, the variability inherent in crosslink determinations can be reduced by collecting urine for longer periods. In research studies, the high variability of single-void collections, compounded by creatinine normalization, may alter or obscure findings.

  10. Fluid sample collection and distribution system. [qualitative analysis of aqueous samples from several points

    NASA Technical Reports Server (NTRS)

    Brooks, R. L. (Inventor)

    1979-01-01

    A multipoint fluid sample collection and distribution system is provided wherein the sample inputs are made through one or more of a number of sampling valves to a progressive cavity pump which is not susceptible to damage by large unfiltered particles. The pump output is through a filter unit that can provide a filtered multipoint sample. An unfiltered multipoint sample is also provided. An effluent sample can be taken and applied to a second progressive cavity pump for pumping to a filter unit that can provide one or more filtered effluent samples. The second pump can also provide an unfiltered effluent sample. Means are provided to periodically back flush each filter unit without shutting off the whole system.

  11. Driving simulator validation of driver behavior with limited safe vantage points for data collection in work zones.

    PubMed

    Bham, Ghulam H; Leu, Ming C; Vallati, Manoj; Mathur, Durga R

    2014-06-01

    This study is aimed at validating a driving simulator (DS) for the study of driver behavior in work zones. A validation study requires field data collection. For studies conducted in highway work zones, the availability of safe vantage points for data collection at critical locations can be a significant challenge. A validation framework is therefore proposed in this paper, demonstrated using a fixed-based DS that addresses the issue by using a global positioning system (GPS). The validation of the DS was conducted using objective and subjective evaluations. The objective validation was divided into qualitative and quantitative evaluations. The DS was validated by comparing the results of simulation with the field data, which were collected using a GPS along the highway and video recordings at specific locations in a work zone. The constructed work zone scenario in the DS was subjectively evaluated with 46 participants. The objective evaluation established the absolute and relative validity of the DS. The mean speeds from the DS data showed excellent agreement with the field data. The subjective evaluation indicated realistic driving experience by the participants. The use of GPS showed that continuous data collected along the highway can overcome the challenges of unavailability of safe vantage points especially at critical locations. Further, a validated DS can be used for examining driver behavior in complex situations by replicating realistic scenarios. Copyright © 2014 Elsevier Ltd. All rights reserved.

  12. Validation of a multiplex electrochemiluminescent immunoassay platform in human and mouse samples

    PubMed Central

    Bastarache, J.A.; Koyama, T.; Wickersham, N.E; Ware, L.B.

    2014-01-01

    Despite the widespread use of multiplex immunoassays, there are very few scientific reports that test the accuracy and reliability of a platform prior to publication of experimental data. Our laboratory has previously demonstrated the need for new assay platform validation prior to use of biologic samples from large studies in order to optimize sample handling and assay performance. In this study, our goal was to test the accuracy and reproducibility of an electrochemiluminescent multiplex immunoassay platform (Meso Scale Discovery, MSD®) and compare this platform to validated, singleplex immunoassays (R&D Systems®) using actual study subject (human plasma and mouse bronchoalveolar lavage fluid (BALF) and plasma) samples. We found that the MSD platform performed well on intra- and inter-assay comparisons, spike and recovery and cross-platform comparisons. The mean intra-assay CV% and range for MSD was 3.49 (0.0-10.4) for IL-6 and 2.04 (0.1-7.9) for IL-8. The correlation between values for identical samples measured on both MSD and R&D was R=0.97 for both analytes. The mouse MSD assay had a broader range of CV% with means ranging from 9.5-28.5 depending on the analyte. The range of mean CV% was similar for single plex ELISAs at 4.3-23.7 depending on the analyte. Regardless of species or sample type, CV% was more variable at lower protein concentrations. In conclusion, we validated a multiplex electrochemiluminscent assay system and found that it has superior test characteristics in human plasma compared to mouse BALF and plasma. Both human and MSD assays compared favorably to well-validated singleplex ELISA's PMID:24768796

  13. Efficiency of Different Sampling Tools for Aquatic Macroinvertebrate Collections in Malaysian Streams

    PubMed Central

    Ghani, Wan Mohd Hafezul Wan Abdul; Rawi, Che Salmah Md; Hamid, Suhaila Abd; Al-Shami, Salman Abdo

    2016-01-01

    This study analyses the sampling performance of three benthic sampling tools commonly used to collect freshwater macroinvertebrates. Efficiency of qualitative D-frame and square aquatic nets were compared to a quantitative Surber sampler in tropical Malaysian streams. The abundance and diversity of macroinvertebrates collected using each tool evaluated along with their relative variations (RVs). Each tool was used to sample macroinvertebrates from three streams draining different areas: a vegetable farm, a tea plantation and a forest reserve. High macroinvertebrate diversities were recorded using the square net and Surber sampler at the forested stream site; however, very low species abundance was recorded by the Surber sampler. Relatively large variations in the Surber sampler collections (RVs of 36% and 28%) were observed for the vegetable farm and tea plantation streams, respectively. Of the three sampling methods, the square net was the most efficient, collecting a greater diversity of macroinvertebrate taxa and a greater number of specimens (i.e., abundance) overall, particularly from the vegetable farm and the tea plantation streams (RV<25%). Fewer square net sample passes (<8 samples) were sufficient to perform a biological assessment of water quality, but each sample required a slightly longer processing time (±20 min) compared with those gathered via the other samplers. In conclusion, all three apparatuses were suitable for macroinvertebrate collection in Malaysian streams and gathered assemblages that resulted in the determination of similar biological water quality classes using the Family Biotic Index (FBI) and the Biological Monitoring Working Party (BMWP). However, despite a slightly longer processing time, the square net was more efficient (lowest RV) at collecting samples and more suitable for the collection of macroinvertebrates from deep, fast flowing, wadeable streams with coarse substrates. PMID:27019685

  14. Underway Sampling of Marine Inherent Optical Properties on the Tara Oceans Expedition as a Novel Resource for Ocean Color Satellite Data Product Validation

    NASA Technical Reports Server (NTRS)

    Werdell, P. Jeremy; Proctor, Christopher W.; Boss, Emmanuel; Leeuw, Thomas; Ouhssain, Mustapha

    2013-01-01

    Developing and validating data records from operational ocean color satellite instruments requires substantial volumes of high quality in situ data. In the absence of broad, institutionally supported field programs, organizations such as the NASA Ocean Biology Processing Group seek opportunistic datasets for use in their operational satellite calibration and validation activities. The publicly available, global biogeochemical dataset collected as part of the two and a half year Tara Oceans expedition provides one such opportunity. We showed how the inline measurements of hyperspectral absorption and attenuation coefficients collected onboard the R/V Tara can be used to evaluate near-surface estimates of chlorophyll-a, spectral particulate backscattering coefficients, particulate organic carbon, and particle size classes derived from the NASA Moderate Resolution Imaging Spectroradiometer onboard Aqua (MODISA). The predominant strength of such flow-through measurements is their sampling rate-the 375 days of measurements resulted in 165 viable MODISA-to-in situ match-ups, compared to 13 from discrete water sampling. While the need to apply bio-optical models to estimate biogeochemical quantities of interest from spectroscopy remains a weakness, we demonstrated how discrete samples can be used in combination with flow-through measurements to create data records of sufficient quality to conduct first order evaluations of satellite-derived data products. Given an emerging agency desire to rapidly evaluate new satellite missions, our results have significant implications on how calibration and validation teams for these missions will be constructed.

  15. Sample Collection for Investigation of Mars (SCIM): An Early Mars Sample Return Mission Through the Mars Scout Program

    NASA Technical Reports Server (NTRS)

    Leshin, L. A.; Yen, A.; Bomba, J.; Clark, B.; Epp, C.; Forney, L.; Gamber, T.; Graves, C.; Hupp, J.; Jones, S.

    2002-01-01

    The Sample Collection for Investigation of Mars (SCIM) mission is designed to: (1) make a 40 km pass through the Martian atmosphere; (2) collect dust and atmospheric gas; and (3) return the samples to Earth for analysis. Additional information is contained in the original extended abstract.

  16. Plume Collection Strategies for Icy World Sample Return

    NASA Technical Reports Server (NTRS)

    Neveu, M.; Glavin, D. P.; Tsou, P.; Anbar, A. D.; Williams, P.

    2015-01-01

    Three icy worlds in the solar system display evidence of pluming activity. Water vapor and ice particles emanate from cracks near the south pole of Saturn's moon Enceladus. The plume gas contains simple hydrocarbons that could be fragments of larger, more complex organics. More recently, observations using the Hubble and Herschel space telescopes have hinted at transient water vapor plumes at Jupiter's moon Europa and the dwarf planet Ceres. Plume materials may be ejected directly from possible sub-surface oceans, at least on Enceladus. In such oceans, liquid water, organics, and energy may co-exist, making these environments habitable. The venting of habitable ocean material into space provides a unique opportunity to capture this material during a relatively simple flyby mission and return it to Earth. Plume collection strategies should enable investigations of evidence for life in the returned samples via laboratory analyses of the structure, distribution, isotopic composition, and chirality of the chemical components (including biomolecules) of plume materials. Here, we discuss approaches for the collection of dust and volatiles during flybys through Enceladus' plume, based on Cassini results and lessons learned from the Stardust comet sample return mission. We also highlight areas where sample collector and containment technology development and testing may be needed for future plume sample return missions.

  17. 21 CFR 111.80 - What representative samples must you collect?

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... Process Control System § 111.80 What representative samples must you collect? The representative samples... unique lot within each unique shipment); (b) Representative samples of in-process materials for each manufactured batch at points, steps, or stages, in the manufacturing process as specified in the master...

  18. The Predictive Validity of Four Intelligence Tests for School Grades: A Small Sample Longitudinal Study

    PubMed Central

    Gygi, Jasmin T.; Hagmann-von Arx, Priska; Schweizer, Florine; Grob, Alexander

    2017-01-01

    Intelligence is considered the strongest single predictor of scholastic achievement. However, little is known regarding the predictive validity of well-established intelligence tests for school grades. We analyzed the predictive validity of four widely used intelligence tests in German-speaking countries: The Intelligence and Development Scales (IDS), the Reynolds Intellectual Assessment Scales (RIAS), the Snijders-Oomen Nonverbal Intelligence Test (SON-R 6-40), and the Wechsler Intelligence Scale for Children (WISC-IV), which were individually administered to 103 children (Mage = 9.17 years) enrolled in regular school. School grades were collected longitudinally after 3 years (averaged school grades, mathematics, and language) and were available for 54 children (Mage = 11.77 years). All four tests significantly predicted averaged school grades. Furthermore, the IDS and the RIAS predicted both mathematics and language, while the SON-R 6-40 predicted mathematics. The WISC-IV showed no significant association with longitudinal scholastic achievement when mathematics and language were analyzed separately. The results revealed the predictive validity of currently used intelligence tests for longitudinal scholastic achievement in German-speaking countries and support their use in psychological practice, in particular for predicting averaged school grades. However, this conclusion has to be considered as preliminary due to the small sample of children observed. PMID:28348543

  19. Data Validation Package, April and June 2016 Groundwater and Surface Water Sampling at the Gunnison, Colorado, Processing Site, October 2016

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Linard, Joshua; Campbell, Sam

    This event included annual sampling of groundwater and surface water locations at the Gunnison, Colorado, Processing Site. Sampling and analyses were conducted as specified in Sampling and Analysis Plan for US Department of Energy Office of Legacy Management Sites (LMS/PRO/S04351, continually updated, http://energy.gov/lm/downloads/sampling-and­ analysis-plan-us-department-energy-office-legacy-management-sites). Samples were collected from 28 monitoring wells, three domestic wells, and six surface locations in April at the processing site as specified in the draft 2010 Ground Water Compliance Action Plan for the Gunnison, Colorado, Processing Site. Planned monitoring locations are shown in Attachment 1, Sampling and Analysis Work Order. Domestic wells 0476 and 0477 weremore » sampled in June because the homes were unoccupied in April, and the wells were not in use. Duplicate samples were collected from locations 0126, 0477, and 0780. One equipment blank was collected during this sampling event. Water levels were measured at all monitoring wells that were sampled. See Attachment 2, Trip Reports for additional details. The analytical data and associated qualifiers can be viewed in environmental database reports and are also available for viewing with dynamic mapping via the GEMS (Geospatial Environmental Mapping System) website at http://gems.lm.doe.gov/#. No issues were identified during the data validation process that requires additional action or follow-up. An assessment of anomalous data is included in Attachment 3. Interpretation and presentation of results, including an assessment ofthe natural flushing compliance strategy, will be reported in the upcoming 2016 Verification Monitoring Report. U.S.« less

  20. Validity of the SAT® for Predicting First-Year Grades: 2011 SAT Validity Sample. Statistical Report 2013-3

    ERIC Educational Resources Information Center

    Patterson, Brian F.; Mattern, Krista D.

    2013-01-01

    The continued accumulation of validity evidence for the intended uses of educational assessments is critical to ensure that proper inferences will be made for those purposes. To that end, the College Board has continued to collect college outcome data to evaluate the relationship between SAT® scores and college success. This report provides…

  1. Validity of the SAT® for Predicting First-Year Grades: 2012 SAT Validity Sample. Statistical Report 2015 2

    ERIC Educational Resources Information Center

    Beard, Jonathan; Marini, Jessica P.

    2015-01-01

    The continued accumulation of validity evidence for the intended uses of educational assessment scores is critical to ensure that inferences made using the scores are sound. To that end, the College Board has continued to collect college outcome data to evaluate the relationship between SAT® scores and college success. This report provides updated…

  2. A FIELD VALIDATION OF TWO SEDIMENT-AMPHIPOD TOXICITY TESTS

    EPA Science Inventory

    A field validation study of two sediment-amphipod toxicity tests was conducted using sediment samples collected subtidally in the vicinity of a polycyclic aromatic hydrocarbon (PAH)-contaminated Superfund site in Elliott Bay, WA, USA. Sediment samples were collected at 30 stati...

  3. Lunar Samples: Apollo Collection Tools, Curation Handling, Surveyor III and Soviet Luna Samples

    NASA Technical Reports Server (NTRS)

    Allton, J.H.

    2009-01-01

    The 6 Apollo missions that landed on the lunar surface returned 2196 samples comprised of 382 kg. The 58 samples weighing 21.5 kg collected on Apollo 11 expanded to 741 samples weighing 110.5 kg by the time of Apollo 17. The main goal on Apollo 11 was to obtain some material and return it safely to Earth. As we gained experience, the sampling tools and a more specific sampling strategy evolved. A summary of the sample types returned is shown in Table 1. By year 1989, some statistics on allocation by sample type were compiled [2]. The "scientific interest index" is based on the assumption that the more allocations per gram of sample, the higher the scientific interest. It is basically a reflection of the amount of diversity within a given sample type. Samples were also set aside for biohazard testing. The samples set aside and used for biohazard testing were represen-tative, as opposed to diverse. They tended to be larger and be comprised of less scientifically valuable mate-rial, such as dust and debris in the bottom of sample containers.

  4. Contamination Knowledge Strategy for the Mars 2020 Sample-Collecting Rover

    NASA Technical Reports Server (NTRS)

    Farley, K. A.; Williford, K.; Beaty, D W.; McSween, H. Y.; Czaja, A. D.; Goreva, Y. S.; Hausrath, E.; Herd, C. D. K.; Humayun, M.; McCubbin, F. M.; hide

    2017-01-01

    The Mars 2020 rover will collect carefully selected samples of rock and regolith as it explores a potentially habitable ancient environment on Mars. Using the drill, rock cores and regolith will be collected directly into ultraclean sample tubes that are hermetically sealed and, later, deposited on the surface of Mars for potential return to Earth by a subsequent mission. Thorough characterization of any contamination of the samples at the time of their analysis will be essential for achieving the objectives of Mars returned sample science (RSS). We refer to this characterization as contamination knowledge (CK), which is distinct from contamination control (CC). CC is the set of activities that limits the input of contaminating species into a sample, and is specified by requirement thresholds. CK consists of identifying and characterizing both potential and realized contamination to better inform scientific investigations of the returned samples. Based on lessons learned by other sample return missions with contamination-sensitive scientific objectives, CC needs to be "owned" by engineering, but CK needs to be "owned" by science. Contamination present at the time of sample analysis will reflect the sum of contributions from all contamination vectors up to that point in time. For this reason, understanding the integrated history of contamination may be crucial for deciphering potentially confusing contaminant-sensitive observations. Thus, CK collected during the Mars sample return (MSR) campaign must cover the time period from the initiation of hardware construction through analysis of returned samples in labs on Earth. Because of the disciplinary breadth of the scientific objectives of MSR, CK must include a broad spectrum of contaminants covering inorganic (i.e., major, minor, and trace elements), organic, and biological molecules and materials.

  5. OSIRIS-REx Touch-and-Go (TAG) Mission Design for Asteroid Sample Collection

    NASA Technical Reports Server (NTRS)

    May, Alexander; Sutter, Brian; Linn, Timothy; Bierhaus, Beau; Berry, Kevin; Mink, Ron

    2014-01-01

    The Origins Spectral Interpretation Resource Identification Security Regolith Explorer (OSIRIS-REx) mission is a NASA New Frontiers mission launching in September 2016 to rendezvous with the near-Earth asteroid Bennu in October 2018. After several months of proximity operations to characterize the asteroid, OSIRIS-REx flies a Touch-And-Go (TAG) trajectory to the asteroid's surface to collect at least 60 g of pristine regolith sample for Earth return. This paper provides mission and flight system overviews, with more details on the TAG mission design and key events that occur to safely and successfully collect the sample. An overview of the navigation performed relative to a chosen sample site, along with the maneuvers to reach the desired site is described. Safety monitoring during descent is performed with onboard sensors providing an option to abort, troubleshoot, and try again if necessary. Sample collection occurs using a collection device at the end of an articulating robotic arm during a brief five second contact period, while a constant force spring mechanism in the arm assists to rebound the spacecraft away from the surface. Finally, the sample is measured quantitatively utilizing the law of conservation of angular momentum, along with qualitative data from imagery of the sampling device. Upon sample mass verification, the arm places the sample into the Stardust-heritage Sample Return Capsule (SRC) for return to Earth in September 2023.

  6. Analysis of human plasma proteins: a focus on sample collection and separation using free-flow electrophoresis.

    PubMed

    Nissum, Mikkel; Foucher, Aude L

    2008-08-01

    Due to ease of accessibility, plasma has become the sample of choice for proteomics studies directed towards biomarker discovery intended for use in diagnostics, prognostics and even in theranostics. The result of these extensive efforts is a long list of potential biomarkers, very few of which have led to clinical utility. Why have so many potential biomarkers failed validation? Herein, we address certain issues encountered, which complicate biomarker discovery efforts originating from plasma. The advantages of stabilizing the sample at collection by the addition of protease inhibitors are discussed. The principles of free-flow electrophoresis (FFE) separation are provided together with examples applying to various studies. Finally, particular attention is given to plasma or serum analysis using multidimensional separation strategies into which the FFE is incorporated. The advantages of using FFE separation in these workflows are discussed.

  7. Accuracy of human papillomavirus testing on self-collected versus clinician-collected samples: a meta-analysis.

    PubMed

    Arbyn, Marc; Verdoodt, Freija; Snijders, Peter J F; Verhoef, Viola M J; Suonio, Eero; Dillner, Lena; Minozzi, Silvia; Bellisario, Cristina; Banzi, Rita; Zhao, Fang-Hui; Hillemanns, Peter; Anttila, Ahti

    2014-02-01

    Screening for human papillomavirus (HPV) infection is more effective in reducing the incidence of cervical cancer than screening using Pap smears. Moreover, HPV testing can be done on a vaginal sample self-taken by a woman, which offers an opportunity to improve screening coverage. However, the clinical accuracy of HPV testing on self-samples is not well-known. We assessed whether HPV testing on self-collected samples is equivalent to HPV testing on samples collected by clinicians. We identified relevant studies through a search of PubMed, Embase, and CENTRAL. Studies were eligible for inclusion if they fulfilled all of the following selection criteria: a cervical cell sample was self-collected by a woman followed by a sample taken by a clinician; a high-risk HPV test was done on the self-sample (index test) and HPV-testing or cytological interpretation was done on the specimen collected by the clinician (comparator tests); and the presence or absence of cervical intraepithelial neoplasia grade 2 (CIN2) or worse was verified by colposcopy and biopsy in all enrolled women or in women with one or more positive tests. The absolute accuracy for finding CIN2 or worse, or CIN grade 3 (CIN3) or worse of the index and comparator tests as well as the relative accuracy of the index versus the comparator tests were pooled using bivariate normal models and random effect models. We included data from 36 studies, which altogether enrolled 154 556 women. The absolute accuracy varied by clinical setting. In the context of screening, HPV testing on self-samples detected, on average, 76% (95% CI 69-82) of CIN2 or worse and 84% (72-92) of CIN3 or worse. The pooled absolute specificity to exclude CIN2 or worse was 86% (83-89) and 87% (84-90) to exclude CIN3 or worse. The variation of the relative accuracy of HPV testing on self-samples compared with tests on clinician-taken samples was low across settings, enabling pooling of the relative accuracy over all studies. The pooled

  8. A 'feather-trap' for collecting DNA samples from birds.

    PubMed

    Maurer, Golo; Beck, Nadeena; Double, Michael C

    2010-01-01

    Genetic analyses of birds are usually based on DNA extracted from a blood sample. For some species, however, obtaining blood samples is difficult because they are sensitive to handling, pose a conservation or animal welfare concern, or evade capture. In such cases, feathers obtained from live birds in the wild can provide an alternative source of DNA. Here, we provide the first description and evaluation of a 'feather-trap', consisting of small strips of double-sided adhesive tape placed close to a nest with chicks, as a simple, inexpensive and minimally invasive method to collect feathers. The feather-trap was tested in tropical conditions on the Australian pheasant coucal (Centropus phasianinus). None of the 12 pairs of coucals on which the feather-trap was used abandoned the nest, and feeding rates did not differ from those of birds not exposed to a feather-trap. On average, 4.2 feathers were collected per trap over 2-5 days and, despite exposure to monsoonal rain, DNA was extracted from 71.4% of samples, albeit at low concentrations. The amount of genomic DNA extracted from each feather was sufficient to reliably genotype individuals at up to five microsatellite loci for parentage analysis. We show that a feather-trap can provide a reliable alternative for obtaining DNA in species where taking blood is difficult. It may also prove useful for collecting feather samples for other purposes, e.g. stable-isotope analysis. © 2009 Blackwell Publishing Ltd.

  9. Fitting distributions to microbial contamination data collected with an unequal probability sampling design.

    PubMed

    Williams, M S; Ebel, E D; Cao, Y

    2013-01-01

    The fitting of statistical distributions to microbial sampling data is a common application in quantitative microbiology and risk assessment applications. An underlying assumption of most fitting techniques is that data are collected with simple random sampling, which is often times not the case. This study develops a weighted maximum likelihood estimation framework that is appropriate for microbiological samples that are collected with unequal probabilities of selection. A weighted maximum likelihood estimation framework is proposed for microbiological samples that are collected with unequal probabilities of selection. Two examples, based on the collection of food samples during processing, are provided to demonstrate the method and highlight the magnitude of biases in the maximum likelihood estimator when data are inappropriately treated as a simple random sample. Failure to properly weight samples to account for how data are collected can introduce substantial biases into inferences drawn from the data. The proposed methodology will reduce or eliminate an important source of bias in inferences drawn from the analysis of microbial data. This will also make comparisons between studies and the combination of results from different studies more reliable, which is important for risk assessment applications. © 2012 No claim to US Government works.

  10. SNS Sample Activation Calculator Flux Recommendations and Validation

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    McClanahan, Tucker C.; Gallmeier, Franz X.; Iverson, Erik B.

    The Spallation Neutron Source (SNS) at Oak Ridge National Laboratory (ORNL) uses the Sample Activation Calculator (SAC) to calculate the activation of a sample after the sample has been exposed to the neutron beam in one of the SNS beamlines. The SAC webpage takes user inputs (choice of beamline, the mass, composition and area of the sample, irradiation time, decay time, etc.) and calculates the activation for the sample. In recent years, the SAC has been incorporated into the user proposal and sample handling process, and instrument teams and users have noticed discrepancies in the predicted activation of their samples.more » The Neutronics Analysis Team validated SAC by performing measurements on select beamlines and confirmed the discrepancies seen by the instrument teams and users. The conclusions were that the discrepancies were a result of a combination of faulty neutron flux spectra for the instruments, improper inputs supplied by SAC (1.12), and a mishandling of cross section data in the Sample Activation Program for Easy Use (SAPEU) (1.1.2). This report focuses on the conclusion that the SAPEU (1.1.2) beamline neutron flux spectra have errors and are a significant contributor to the activation discrepancies. The results of the analysis of the SAPEU (1.1.2) flux spectra for all beamlines will be discussed in detail. The recommendations for the implementation of improved neutron flux spectra in SAPEU (1.1.3) are also discussed.« less

  11. Evaluation of a standardized micro-vacuum sampling method for collection of surface dust.

    PubMed

    Ashley, Kevin; Applegate, Gregory T; Wise, Tamara J; Fernback, Joseph E; Goldcamp, Michael J

    2007-03-01

    A standardized procedure for collecting dust samples from surfaces using a micro-vacuum sampling technique was evaluated. Experiments were carried out to investigate the collection efficiency of the vacuum sampling method described in ASTM Standard D7144, "Standard Practice for Collection of Surface Dust by Micro-Vacuum Sampling for Subsequent Metals Determination." Weighed masses ( approximately 5, approximately 10 and approximately 25 mg) of three NIST Standard Reference Materials (SRMs) were spiked onto surfaces of various substrates. The SRMs used were: (1) Powdered Lead-Based Paint; (2) Urban Particulate Matter; and (3) Trace Elements in Indoor Dust. Twelve different substrate materials were chosen to be representative of surfaces commonly encountered in occupational and/or indoor settings: (1) wood, (2) tile, (3) linoleum, (4) vinyl, (5) industrial carpet, (6) plush carpet, (7,8) concrete block (painted and unpainted), (9) car seat material, (10) denim, (11) steel, and (12) glass. Samples of SRMs originally spiked onto these surfaces were collected using the standardized micro-vacuum sampling procedure. Gravimetric analysis of material collected within preweighed Accucapinserts (housed within the samplers) was used to measure SRM recoveries. Recoveries ranged from 21.6% (+/- 10.4%, 95% confidence limit [CL]) for SRM 1579 from industrial carpet to 59.2% (+/- 11.0%, 95% CL) for SRM 1579 from glass. For most SRM/substrate combinations, recoveries ranged from approximately 25% to approximately 50%; variabilities differed appreciably. In general, SRM recoveries were higher from smooth and hard surfaces and lower from rough and porous surfaces. Material captured within collection nozzles attached to the sampler inlets was also weighed. A significant fraction of SRM originally spiked onto substrate surfaces was captured within collection nozzles. Percentages of SRMs captured within collection nozzles ranged from approximately 13% (+/- 4 - +/- 5%, 95% CLs) for SRMs

  12. [Adolescents find it easy to collect their own samples to study sexually transmitted infections].

    PubMed

    Huneeus, Andrea; Fernández, Mario I; Schilling, Andrea; Parra, Paulina; Zakharova, Aleksandra

    2017-04-01

    As alternative for patients that fear genital examination, we assessed adolescent's comfort and ease with self-collected samples for nucleic acid amplification testing for sexually transmitted infections. Sexually active Chilean adolescents and youth under 25 years (174 males and 117 females) were enrolled. Females used self-collected vaginal swabs and males collected first-stream urine. A satisfaction survey evaluating self-sampling system was applied. Self-collection was considered easy in 99.3% of the interviewees (CI 95% 0.88-0.98). In women, 79.3% preferred vaginal self-collected samples than pelvic exam (CI 95% 0.73-0.85). In men, 80.3% preferred self-collected first-stream urine to urethral swabs (CI 95% 0.73-0.87). Assuming that self-collected sampling were available, 89.6% of women (CI 95% 0.85-0.94) and 93.2% of men (CI 95% 0.89-0.98) would be prone to be tested more often. Ease of self-collected sampling is not associated with age, gender, educational level or poverty. Chile currently does not have sexually transmitted infections surveillance or screening programs for youth and adolescents. Given self-collected sampling's good acceptability, it could be successfully used when these programs are implemented.

  13. Validation of an off line solid phase extraction liquid chromatography-tandem mass spectrometry method for the determination of systemic insecticide residues in honey and pollen samples collected in apiaries from NW Spain.

    PubMed

    García-Chao, María; Agruña, María Jesús; Flores Calvete, Gonzalo; Sakkas, Vasilis; Llompart, María; Dagnac, Thierry

    2010-07-05

    11843 standard for the following parameters: decision limit (CCalpha), detection capability (CCbeta), recovery, repeatability and reproducibility at 0.5, 1 and 1.5 folds the MRLs. Ion suppression/enhancement effects into the ion source were also assessed. The CCbeta values were included between 0.83 and 4.83 ng g(-1), well below the current MRLs. The validated method was applied to the determination of the target pesticides in 91 samples collected in colonies from 73 apiaries of NW Spain (two sampling campaigns during 2008). None of the target insecticides were detected among all the collected samples. Copyright 2010 Elsevier B.V. All rights reserved.

  14. Driving under the influence of cannabis: pitfalls, validation, and quality control of a UPLC-MS/MS method for the quantification of tetrahydrocannabinol in oral fluid collected with StatSure, Quantisal, or Certus collector.

    PubMed

    Wille, Sarah M R; Di Fazio, Vincent; Ramírez-Fernandez, Maria del Mar; Kummer, Natalie; Samyn, Nele

    2013-02-01

    "Driving under the influence of drugs" (DUID) has a large impact on the worldwide mortality risk. Therefore, DUID legislations based on impairment or analytical limits are adopted. Drug detection in oral fluid is of interest due to the ease of sampling during roadside controls. The prevalence of Δ9-tetrahydrocannabinol (THC) in seriously injured drivers ranges from 0.5% to 7.6% in Europe. For these reasons, the quantification of THC in oral fluid collected with 3 alternative on-site collectors is presented and discussed in this publication. An ultra-performance liquid chromatography-mass spectrometric quantification method for THC in oral fluid samples collected with the StatSure (Diagnostic Systems), Quantisal (Immunalysis), and Certus (Concateno) devices was validated according to the international guidelines. Small sample volumes of 100-200 μL were extracted using hexane. Special attention was paid to factors such as matrix effects, THC adsorption onto the collector, and stability in the collection fluid. A relatively high-throughput analysis was developed and validated according to ISO 17025 requirements. Although the effects of the matrix on the quantification could be minimized using a deuterated internal standard, and stability was acceptable according the validation data, adsorption of THC onto the collectors was a problem. For the StatSure device, THC was totally recovered from the collector pad after storage for 24 hours at room temperature or 7 days at 4°C. A loss of 15%-25% was observed for the Quantisal collector, whereas the recovery from the Certus device was irreproducible (relative standard deviation, 44%-85%) and low (29%-80%). During the roadside setting, a practical problem arose: small volumes of oral fluid (eg, 300 μL) were collected. However, THC was easily detected and concentrations ranged from 8 to 922 ng/mL in neat oral fluid. A relatively high-throughput analysis (40 samples in 4 hours) adapted for routine DUID analysis was developed

  15. The Internet of Samples in the Earth Sciences: Providing Access to Uncurated Collections

    NASA Astrophysics Data System (ADS)

    Carter, M. R.; Lehnert, K. A.

    2014-12-01

    Vast amounts of physical samples have been collected in the Earth Sciences for studies that address a wide range of scientific questions. Only a fraction of these samples are well curated and preserved long-term in sample repositories and museums. Many samples and collections are stored in the offices and labs of investigators, or in basements and sheds of institutions and investigators' homes. These 'uncurated' collections often contain samples that have been well studied, or are unique and irreplaceable. They may also include samples that could reveal new insights if re-analyzed using new techniques, or specimens that could have unanticipated relevance to research being conducted in fields other than the one for which they were collected. Currently, these samples cannot be accessed or discovered online by the broader science community. Investigators and departments often lack the resources to properly catalog and curate the samples and respond to requests for splits. Long-term preservation of and access to these samples is usually not provided for. iSamplES, a recently-funded EarthCube Research Coordination Network (RCN), seeks to integrate scientific samples, including 'uncurated' samples, into digital data and information infrastructure in the Earth Sciences and to facilitate their curation, discovery, access, sharing, and analysis. The RCN seeks to develop and implement best practices that increase digital access to samples with the goal of establishing a comprehensive infrastructure not only for the digital, but also physical curation of samples. The RCN will engage a broad group of individuals from domain scientists to curators to publishers to computer scientists to define, articulate, and address the needs and challenges of digital sample management and recommend community-endorsed best practices and standards for registering, describing, identifying, and citing physical specimens, drawing upon other initiatives and existing or emerging software tools for

  16. Collection of Oral Fluids Using Cotton Ropes as a Sampling Method to Detect Foot-and-Mouth Disease Virus Infection in Pigs.

    PubMed

    Vosloo, W; Morris, J; Davis, A; Giles, M; Wang, J; Nguyen, H T T; Kim, P V; Quach, N V; Le, P T T; Nguyen, P H N; Dang, H; Tran, H X; Vu, P P; Hung, V V; Le, Q T; Tran, T M; Mai, T M T; Le, Q T V; Singanallur, N B

    2015-10-01

    In high-density farming practices, it is important to constantly monitor for infectious diseases, especially diseases that have the potential to spread rapidly between holdings. Pigs are known to amplify foot-and-mouth disease (FMD) by excreting large amounts of virus, and it is therefore important to detect the virus quickly and accurately to minimize the spread of disease. Ropes were used to collect oral fluid samples from pigs, and each sample was compared to saliva samples collected from individual animals by detecting FMD virus RNA using real-time PCR. Two different experiments are described where groups of pigs were infected with different serotypes of FMD virus, either with or without vaccination, and unvaccinated pigs were kept in aerosol contact. The sensitivity of the rope sampling varied between 0.67 and 0.92, and the statistical agreement between this method and individual sampling ranged from substantial to moderate for the two different serotypes. The ease of collecting oral fluids using ropes together with the high sensitivity of subsequent FMD detection through PCR indicates that this could be a useful method to monitor pig populations for FMD virus infection. With further validation of the sensitivity of detection of FMD virus RNA, this can be a cost-effective, non-invasive diagnostic tool. © 2013 Blackwell Verlag GmbH.

  17. Validation of electronic systems to collect patient-reported outcome (PRO) data-recommendations for clinical trial teams: report of the ISPOR ePRO systems validation good research practices task force.

    PubMed

    Zbrozek, Arthur; Hebert, Joy; Gogates, Gregory; Thorell, Rod; Dell, Christopher; Molsen, Elizabeth; Craig, Gretchen; Grice, Kenneth; Kern, Scottie; Hines, Sheldon

    2013-06-01

    Outcomes research literature has many examples of high-quality, reliable patient-reported outcome (PRO) data entered directly by electronic means, ePRO, compared to data entered from original results on paper. Clinical trial managers are increasingly using ePRO data collection for PRO-based end points. Regulatory review dictates the rules to follow with ePRO data collection for medical label claims. A critical component for regulatory compliance is evidence of the validation of these electronic data collection systems. Validation of electronic systems is a process versus a focused activity that finishes at a single point in time. Eight steps need to be described and undertaken to qualify the validation of the data collection software in its target environment: requirements definition, design, coding, testing, tracing, user acceptance testing, installation and configuration, and decommissioning. These elements are consistent with recent regulatory guidance for systems validation. This report was written to explain how the validation process works for sponsors, trial teams, and other users of electronic data collection devices responsible for verifying the quality of the data entered into relational databases from such devices. It is a guide on the requirements and documentation needed from a data collection systems provider to demonstrate systems validation. It is a practical source of information for study teams to ensure that ePRO providers are using system validation and implementation processes that will ensure the systems and services: operate reliably when in practical use; produce accurate and complete data and data files; support management control and comply with any existing regulations. Furthermore, this short report will increase user understanding of the requirements for a technology review leading to more informed and balanced recommendations or decisions on electronic data collection methods. Copyright © 2013 International Society for

  18. On the improvement of blood sample collection at clinical laboratories

    PubMed Central

    2014-01-01

    Background Blood samples are usually collected daily from different collection points, such hospitals and health centers, and transported to a core laboratory for testing. This paper presents a project to improve the collection routes of two of the largest clinical laboratories in Spain. These routes must be designed in a cost-efficient manner while satisfying two important constraints: (i) two-hour time windows between collection and delivery, and (ii) vehicle capacity. Methods A heuristic method based on a genetic algorithm has been designed to solve the problem of blood sample collection. The user enters the following information for each collection point: postal address, average collecting time, and average demand (in thermal containers). After implementing the algorithm using C programming, this is run and, in few seconds, it obtains optimal (or near-optimal) collection routes that specify the collection sequence for each vehicle. Different scenarios using various types of vehicles have been considered. Unless new collection points are added or problem parameters are changed substantially, routes need to be designed only once. Results The two laboratories in this study previously planned routes manually for 43 and 74 collection points, respectively. These routes were covered by an external carrier company. With the implementation of this algorithm, the number of routes could be reduced from ten to seven in one laboratory and from twelve to nine in the other, which represents significant annual savings in transportation costs. Conclusions The algorithm presented can be easily implemented in other laboratories that face this type of problem, and it is particularly interesting and useful as the number of collection points increases. The method designs blood collection routes with reduced costs that meet the time and capacity constraints of the problem. PMID:24406140

  19. Refining Collective Coordinates and Improving Free Energy Representation in Variational Enhanced Sampling.

    PubMed

    Yang, Yi Isaac; Parrinello, Michele

    2018-06-12

    Collective variables are used often in many enhanced sampling methods, and their choice is a crucial factor in determining sampling efficiency. However, at times, searching for good collective variables can be challenging. In a recent paper, we combined time-lagged independent component analysis with well-tempered metadynamics in order to obtain improved collective variables from metadynamics runs that use lower quality collective variables [ McCarty, J.; Parrinello, M. J. Chem. Phys. 2017 , 147 , 204109 ]. In this work, we extend these ideas to variationally enhanced sampling. This leads to an efficient scheme that is able to make use of the many advantages of the variational scheme. We apply the method to alanine-3 in water. From an alanine-3 variationally enhanced sampling trajectory in which all the six dihedral angles are biased, we extract much better collective variables able to describe in exquisite detail the protein complex free energy surface in a low dimensional representation. The success of this investigation is helped by a more accurate way of calculating the correlation functions needed in the time-lagged independent component analysis and from the introduction of a new basis set to describe the dihedral angles arrangement.

  20. Device for collecting and analyzing matrix-isolated samples

    DOEpatents

    Reedy, Gerald T.

    1979-01-01

    A gas-sample collection device is disclosed for matrix isolation of individual gas bands from a gas chromatographic separation and for presenting these distinct samples for spectrometric examination. The device includes a vacuum chamber containing a rotatably supported, specular carrousel having a number of external, reflecting surfaces around its axis of rotation for holding samples. A gas inlet is provided for depositing sample and matrix material on the individual reflecting surfaces maintained at a sufficiently low temperature to cause solidification. Two optical windows or lenses are installed in the vacuum chamber walls for transmitting a beam of electromagnetic radiation, for instance infrared light, through a selected sample. Positioned within the chamber are two concave mirrors, the first aligned to receive the light beam from one of the lenses and focus it to the sample on one of the reflecting surfaces of the carrousel. The second mirror is aligned to receive reflected light from that carrousel surface and to focus it outwardly through the second lens. The light beam transmitted from the sample is received by a spectrometer for determining absorption spectra.

  1. A sampling plan for conduit-flow karst springs: Minimizing sampling cost and maximizing statistical utility

    USGS Publications Warehouse

    Currens, J.C.

    1999-01-01

    Analytical data for nitrate and triazines from 566 samples collected over a 3-year period at Pleasant Grove Spring, Logan County, KY, were statistically analyzed to determine the minimum data set needed to calculate meaningful yearly averages for a conduit-flow karst spring. Results indicate that a biweekly sampling schedule augmented with bihourly samples from high-flow events will provide meaningful suspended-constituent and dissolved-constituent statistics. Unless collected over an extensive period of time, daily samples may not be representative and may also be autocorrelated. All high-flow events resulting in a significant deflection of a constituent from base-line concentrations should be sampled. Either the geometric mean or the flow-weighted average of the suspended constituents should be used. If automatic samplers are used, then they may be programmed to collect storm samples as frequently as every few minutes to provide details on the arrival time of constituents of interest. However, only samples collected bihourly should be used to calculate averages. By adopting a biweekly sampling schedule augmented with high-flow samples, the need to continuously monitor discharge, or to search for and analyze existing data to develop a statistically valid monitoring plan, is lessened.Analytical data for nitrate and triazines from 566 samples collected over a 3-year period at Pleasant Grove Spring, Logan County, KY, were statistically analyzed to determine the minimum data set needed to calculate meaningful yearly averages for a conduit-flow karst spring. Results indicate that a biweekly sampling schedule augmented with bihourly samples from high-flow events will provide meaningful suspended-constituent and dissolved-constituent statistics. Unless collected over an extensive period of time, daily samples may not be representative and may also be autocorrelated. All high-flow events resulting in a significant deflection of a constituent from base-line concentrations

  2. 21 CFR 864.3260 - OTC test sample collection systems for drugs of abuse testing.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false OTC test sample collection systems for drugs of... Instrumentation and Accessories § 864.3260 OTC test sample collection systems for drugs of abuse testing. (a) Identification. An over-the-counter (OTC) test sample collection system for drugs of abuse testing is a device...

  3. A New Technique for Measuring Concentration Dependence of Self and Collective Diffusivity by using a Single Sample

    NASA Astrophysics Data System (ADS)

    Sirorattanakul, Krittanon; Shen, Chong; Ou-Yang, Daniel

    Diffusivity governs the dynamics of interacting particles suspended in a solvent. At high particle concentration, the interactions between particles become non-negligible, making the values of self and collective diffusivity diverge and concentration-dependent. Conventional methods for measuring this dependency, such as forced Rayleigh scattering, fluorescence correlation spectroscopy (FCS), and dynamic light scattering (DLS) require preparation of multiple samples. We present a new technique to measure this dependency by using only a single sample. Dielectrophoresis (DEP) is used to create concentration gradient in the solution. Across this concentration distribution, we use FCS to measure the concentration-dependent self diffusivity. Then, we switch off DEP to allow the particles to diffuse back to equilibrium. We obtain the time series of concentration distribution from fluorescence microscopy and use them to determine the concentration-dependent collective diffusivity. We compare the experimental results with computer simulations to verify the validity of this technique. Time and spatial resolution limits of FCS and imaging are also analyzed to estimate the limitation of the proposed technique. NSF DMR-0923299, Lehigh College of Arts and Sciences Undergraduate Research Grant, Lehigh Department of Physics, Emulsion Polymers Institute.

  4. [Validation of a scale of attitudes towards sexuality in a sample of Puerto Rican elderly].

    PubMed

    Rodríguez Benítez, Rosa Janet; Rodríguez Gómez, José; Sayers Montalvo, Sean

    2010-01-01

    The literature indicates that elderly population is at high risk that affects their sexual activity; however, this is not the end of sexuality expression in this population. Elderly (people 65 years and older) who are healthy and active has more opportunities of sexual expression and activity in all forms, (including masturbation, and oral sex), and these activities can continue until 74 years or older. This study tries to explore if the Scale of Attitudes towards Sexuality Behavior in the Elderly develop in Puerto Rico, is a valid and reliable instrument to measure attitudes towards the sexuality in an elderly sample. In addition, the research tries to contribute to the progress and development of instruments that measure, and screen, sexuality aspects and risk behaviors that focus in the elderly population. This may help to promote future studies and the development of preventive programs that help to fulfill specific necessities in elderly. The research subjects consist of a secondary database sample of 265 adults of 65 years or older. The design of this study was an ex post facto type. The collected data were analyzed using descriptive statistics and factorial analyses to establish an association between the study variables (i.e., attitudes towards the sexuality and sexuality) using SPSS-X program version 14; also was concluded that the instrument is a valid and reliable (Alpha Cronbach = 0.95), which is considered adequate. It's expected that the scale will be valuable for future research in this area.

  5. Comparison and Field Validation of Binomial Sampling Plans for Oligonychus perseae (Acari: Tetranychidae) on Hass Avocado in Southern California.

    PubMed

    Lara, Jesus R; Hoddle, Mark S

    2015-08-01

    Oligonychus perseae Tuttle, Baker, & Abatiello is a foliar pest of 'Hass' avocados [Persea americana Miller (Lauraceae)]. The recommended action threshold is 50-100 motile mites per leaf, but this count range and other ecological factors associated with O. perseae infestations limit the application of enumerative sampling plans in the field. Consequently, a comprehensive modeling approach was implemented to compare the practical application of various binomial sampling models for decision-making of O. perseae in California. An initial set of sequential binomial sampling models were developed using three mean-proportion modeling techniques (i.e., Taylor's power law, maximum likelihood, and an empirical model) in combination with two-leaf infestation tally thresholds of either one or two mites. Model performance was evaluated using a robust mite count database consisting of >20,000 Hass avocado leaves infested with varying densities of O. perseae and collected from multiple locations. Operating characteristic and average sample number results for sequential binomial models were used as the basis to develop and validate a standardized fixed-size binomial sampling model with guidelines on sample tree and leaf selection within blocks of avocado trees. This final validated model requires a leaf sampling cost of 30 leaves and takes into account the spatial dynamics of O. perseae to make reliable mite density classifications for a 50-mite action threshold. Recommendations for implementing this fixed-size binomial sampling plan to assess densities of O. perseae in commercial California avocado orchards are discussed. © The Authors 2015. Published by Oxford University Press on behalf of Entomological Society of America. All rights reserved. For Permissions, please email: journals.permissions@oup.com.

  6. Astronaut John Young photographed collecting lunar samples

    NASA Technical Reports Server (NTRS)

    1972-01-01

    Astronaut John W. Young, commander of the Apollo 16 lunar landing mission, is photographed collecting lunar samples near North Ray crater during the third Apollo 16 extravehicular activity (EVA-3) at the Descartes landing site. This picture was taken by Astronaut Charles M. Duke Jr., lunar module pilot. Young is using the lunar surface rake and a set of tongs. The Lunar Roving Vehicle is parked in the field of large boulders in the background.

  7. [Formal sample size calculation and its limited validity in animal studies of medical basic research].

    PubMed

    Mayer, B; Muche, R

    2013-01-01

    Animal studies are highly relevant for basic medical research, although their usage is discussed controversially in public. Thus, an optimal sample size for these projects should be aimed at from a biometrical point of view. Statistical sample size calculation is usually the appropriate methodology in planning medical research projects. However, required information is often not valid or only available during the course of an animal experiment. This article critically discusses the validity of formal sample size calculation for animal studies. Within the discussion, some requirements are formulated to fundamentally regulate the process of sample size determination for animal experiments.

  8. Evaluation of sample stability for a quantitative faecal immunochemical test and comparison of two sample collection approaches.

    PubMed

    Mellen, Samantha; de Ferrars, Maria; Chapman, Claire; Bevan, Sarah; Turvill, James; Turnock, Daniel

    2018-01-01

    Background Faecal immunochemical testing is increasingly being used to triage symptomatic patients for suspected colorectal cancer. However, there are limited data on the effect of preanalytical factors on faecal haemoglobin when measured by faecal immunochemical testing. The aim of this work was to evaluate the stability of faecal haemoglobin in faeces and to compare two methods of faecal haemoglobin sampling for faecal immunochemical testing. Methods Six patients provided faeces for faecal haemoglobin measurement which were transferred into specialized collection devices at baseline and at 1, 2, 3 and 7 days after storage at either room temperature or 4°C. A total of 137 patients returned both faeces transferred into the specialized collection device and faeces in a standard collection pot. A quantitative immunoturbidometric method was used to measure faecal haemoglobin and results were compared categorically. Discrepant results were assessed against diagnosis. Results Faecal haemoglobin concentration declined rapidly within a day of storage at room temperature but results remained ≥10 μg Hb/g faeces in 5/6 patients after two days. A faecal haemoglobin result ≥10 μg Hb/g faeces was obtained in 4/6 patients after storage for seven days at 4°C. Results obtained when patients used specialized collection devices were significantly different from results obtained when faeces was transferred into the specialized collection device in the laboratory. Conclusion There is considerable heterogeneity in the sample stability of faecal haemoglobin; therefore, samples should be transferred rapidly into specialized collection devices to prevent false-negative results. Use of collection devices by patients can lead to false-positive results compared with their use in a laboratory.

  9. Psychosocial Adjustment to Illness Scale: Factor structure, reliability, and validity assessment in a sample of Greek breast cancer patients.

    PubMed

    Kolokotroni, Philippa; Anagnostopoulos, Fotios; Missitzis, Ioannis

    2017-07-01

    The study and measurement of psychosocial adjustment is important for evaluating patients' well-being, and assessing the illness's course, treatment's success, and patients' recovery. In this study, internal consistency reliability and construct validity of the Greek version of the Psychosocial Adjustment to Illness Scale-Self-Report (PAIS-SR) were examined. Demographic and psychosocial data were collected from a sample of 243 women with breast cancer, recruited from September 2011 to December 2012. With some exceptions in specific items, the original conceptually-derived PAIS-SR subscales emerged in a seven-factor solution. Social Environment, Job and Household Duties, and Psychological Distress accounted for more of the total variance than other subscales. PAIS-SR showed good internal consistency reliability, with Cronbach's alpha coefficients >0.62. Correlations of PAIS-SR domains with measures of quality of life and posttraumatic stress symptoms supported the convergent validity of the PAIS-SR and its significance for cancer research. The Greek version of the PAIS-SR has acceptable internal consistency reliability and construct validity, as well as satisfactory convergent validity. Results provide some suggestions for the development of programs to evaluate adjustment status and implement psychosocial interventions among breast cancer survivors.

  10. Collecting, archiving and processing DNA from wildlife samples using FTA® databasing paper

    PubMed Central

    Smith, LM; Burgoyne, LA

    2004-01-01

    Background Methods involving the analysis of nucleic acids have become widespread in the fields of traditional biology and ecology, however the storage and transport of samples collected in the field to the laboratory in such a manner to allow purification of intact nucleic acids can prove problematical. Results FTA® databasing paper is widely used in human forensic analysis for the storage of biological samples and for purification of nucleic acids. The possible uses of FTA® databasing paper in the purification of DNA from samples of wildlife origin were examined, with particular reference to problems expected due to the nature of samples of wildlife origin. The processing of blood and tissue samples, the possibility of excess DNA in blood samples due to nucleated erythrocytes, and the analysis of degraded samples were all examined, as was the question of long term storage of blood samples on FTA® paper. Examples of the end use of the purified DNA are given for all protocols and the rationale behind the processing procedures is also explained to allow the end user to adjust the protocols as required. Conclusions FTA® paper is eminently suitable for collection of, and purification of nucleic acids from, biological samples from a wide range of wildlife species. This technology makes the collection and storage of such samples much simpler. PMID:15072582

  11. Developmental validation of a Nextera XT mitogenome Illumina MiSeq sequencing method for high-quality samples.

    PubMed

    Peck, Michelle A; Sturk-Andreaggi, Kimberly; Thomas, Jacqueline T; Oliver, Robert S; Barritt-Ross, Suzanne; Marshall, Charla

    2018-05-01

    Generating mitochondrial genome (mitogenome) data from reference samples in a rapid and efficient manner is critical to harnessing the greater power of discrimination of the entire mitochondrial DNA (mtDNA) marker. The method of long-range target enrichment, Nextera XT library preparation, and Illumina sequencing on the MiSeq is a well-established technique for generating mitogenome data from high-quality samples. To this end, a validation was conducted for this mitogenome method processing up to 24 samples simultaneously along with analysis in the CLC Genomics Workbench and utilizing the AQME (AFDIL-QIAGEN mtDNA Expert) tool to generate forensic profiles. This validation followed the Federal Bureau of Investigation's Quality Assurance Standards (QAS) for forensic DNA testing laboratories and the Scientific Working Group on DNA Analysis Methods (SWGDAM) validation guidelines. The evaluation of control DNA, non-probative samples, blank controls, mixtures, and nonhuman samples demonstrated the validity of this method. Specifically, the sensitivity was established at ≥25 pg of nuclear DNA input for accurate mitogenome profile generation. Unreproducible low-level variants were observed in samples with low amplicon yields. Further, variant quality was shown to be a useful metric for identifying sequencing error and crosstalk. Success of this method was demonstrated with a variety of reference sample substrates and extract types. These studies further demonstrate the advantages of using NGS techniques by highlighting the quantitative nature of heteroplasmy detection. The results presented herein from more than 175 samples processed in ten sequencing runs, show this mitogenome sequencing method and analysis strategy to be valid for the generation of reference data. Copyright © 2018 Elsevier B.V. All rights reserved.

  12. An unmanned mission to Mars with sample collection and in-situ resource utilization

    NASA Technical Reports Server (NTRS)

    1994-01-01

    The design for the Mars Analysis and Return Vehicle with In-Situ Resource Utilization (MARVIN) project is outlined. The MARVIN mission is designed to collect samples of the Martian environment; to produce fuel from local Martian resources; and to use the fuel produced to return the samples to earth. It uses only existing technologies. Exploratory Technologies' mission-design efforts have focused on methods of orbit determination, sample collection, fuel production, power, communications, control, and structural design. Lambert Targeting provided Delta-V's, launch dates, and travel times. The landing site is the Tharsis Plateau, to the southeast of Olympus Mons, chosen for its substantial scientific value. Samples of soil, dust, and atmosphere are collected with lander-based collection devices: the soil sample, with a robotic arm similar to those used in the Viking missions; the atmospheric sample, from a bleed line to the compressor in the fuel-production facility; a dust sample, from the dust-collection container in the fuel-production facility; and a redundant dust sample, with a with a passive filter system, which relies upon neither a power source nor other collection methods. The sample-return capsule (SRC) houses these samples, which are triply contained to prevent contamination. Proven technology can be used to produce methane and oxygen for fuel with relative ease at the landing site: the Sabatier reactor produces methane and water by combining carbon dioxide and hydrogen (brought from earth); the Reverse Water-Gas Shift unit combines carbon dioxide and hydrogen to form carbon monoxide and water; a water-electrolysis unit splits the water into hydrogen and oxygen. The Mars-lander vehicle (MLV) transports the equipment from earth to Mars. The Mars-ascent vehicle (MAV) contains the SRC and the engine, which is the same for both the MLV and the MAV. All equipment that is unnecessary for the Mars-Earth trajectory remains on Mars. This report presents detailed

  13. An unmanned mission to Mars with sample collection and in-situ resource utilization

    NASA Astrophysics Data System (ADS)

    1994-05-01

    The design for the Mars Analysis and Return Vehicle with In-Situ Resource Utilization (MARVIN) project is outlined. The MARVIN mission is designed to collect samples of the Martian environment; to produce fuel from local Martian resources; and to use the fuel produced to return the samples to earth. It uses only existing technologies. Exploratory Technologies' mission-design efforts have focused on methods of orbit determination, sample collection, fuel production, power, communications, control, and structural design. Lambert Targeting provided Delta-V's, launch dates, and travel times. The landing site is the Tharsis Plateau, to the southeast of Olympus Mons, chosen for its substantial scientific value. Samples of soil, dust, and atmosphere are collected with lander-based collection devices: the soil sample, with a robotic arm similar to those used in the Viking missions; the atmospheric sample, from a bleed line to the compressor in the fuel-production facility; a dust sample, from the dust-collection container in the fuel-production facility; and a redundant dust sample, with a with a passive filter system, which relies upon neither a power source nor other collection methods. The sample-return capsule (SRC) houses these samples, which are triply contained to prevent contamination. Proven technology can be used to produce methane and oxygen for fuel with relative ease at the landing site: the Sabatier reactor produces methane and water by combining carbon dioxide and hydrogen (brought from earth); the Reverse Water-Gas Shift unit combines carbon dioxide and hydrogen to form carbon monoxide and water; a water-electrolysis unit splits the water into hydrogen and oxygen. The Mars-lander vehicle (MLV) transports the equipment from earth to Mars. The Mars-ascent vehicle (MAV) contains the SRC and the engine, which is the same for both the MLV and the MAV. All equipment that is unnecessary for the Mars-Earth trajectory remains on Mars. This report presents detailed

  14. Comparison of Collection Methods for Fecal Samples for Discovery Metabolomics in Epidemiologic Studies.

    PubMed

    Loftfield, Erikka; Vogtmann, Emily; Sampson, Joshua N; Moore, Steven C; Nelson, Heidi; Knight, Rob; Chia, Nicholas; Sinha, Rashmi

    2016-11-01

    The gut metabolome may be associated with the incidence and progression of numerous diseases. The composition of the gut metabolome can be captured by measuring metabolite levels in the feces. However, there are little data describing the effect of fecal sample collection methods on metabolomic measures. We collected fecal samples from 18 volunteers using four methods: no solution, 95% ethanol, fecal occult blood test (FOBT) cards, and fecal immunochemical test (FIT). One set of samples was frozen after collection (day 0), and for 95% ethanol, FOBT, and FIT, a second set was frozen after 96 hours at room temperature. We evaluated (i) technical reproducibility within sample replicates, (ii) stability after 96 hours at room temperature for 95% ethanol, FOBT, and FIT, and (iii) concordance of metabolite measures with the putative "gold standard," day 0 samples without solution. Intraclass correlation coefficients (ICC) estimating technical reproducibility were high for replicate samples for each collection method. ICCs estimating stability at room temperature were high for 95% ethanol and FOBT (median ICC > 0.87) but not FIT (median ICC = 0.52). Similarly, Spearman correlation coefficients (r s ) estimating metabolite concordance with the "gold standard" were higher for 95% ethanol (median r s = 0.82) and FOBT (median r s = 0.70) than for FIT (median r s = 0.40). Metabolomic measurements appear reproducible and stable in fecal samples collected with 95% ethanol or FOBT. Concordance with the "gold standard" is highest with 95% ethanol and acceptable with FOBT. Future epidemiologic studies should collect feces using 95% ethanol or FOBT if interested in studying fecal metabolomics. Cancer Epidemiol Biomarkers Prev; 25(11); 1483-90. ©2016 AACR. ©2016 American Association for Cancer Research.

  15. Sampling bias in blending validation and a different approach to homogeneity assessment.

    PubMed

    Kraemer, J; Svensson, J R; Melgaard, H

    1999-02-01

    Sampling of batches studied for validation is reported. A thief particularly suited for granules, rather than cohesive powders, was used in the study. It is shown, as has been demonstrated in the past, that traditional 1x to 3x thief sampling of a blend is biased, and that the bias decreases as the sample size increases. It is shown that taking 50 samples of tablets after blending and testing this subpopulation for normality is a discriminating manner of testing for homogeneity. As a criterion, it is better than sampling at mixer or drum stage would be even if an unbiased sampling device were available.

  16. Molecular identification of Blastocystis sp. subtypes in water samples collected from Black sea, Turkey.

    PubMed

    Koloren, Zeynep; Gulabi, Berivan Basak; Karanis, Panagiotis

    2018-04-01

    The aim of this study was to identify the subtypes of Blastocystis sp. and complete a phylogenetic analysis of 268 water samples that were collected from the Samsun, Amasya and Sinop Provinces of the Black Sea in Turkey, between the years 2011 and 2014. Blastocystis sp. was investigated in 48 uncultured sea water samples that were collected from 4 sites within the Sinop Province. A total of 100 river water samples were collected from 37 sites in the Samsun Province and 120 river water samples were collected from 10 sampling sites within the Amasya Province. The small subunit (SSU) rDNA gene Polymerase chain reaction (PCR) were performed for the detection of Blastocytis sp. and the PCR-positive samples were sequenced. Subsequently, the (SSU) rDNA sequences were aligned by Bioedit and phylogenetic trees were constructed for Blastocystis with reference to the genotypes from GenBank. Blastocystis sp. were found in 3 out of the 75 (4%) river water samples that were collected from the Samsun Province. Six of the 120 (5%) river water samples and 1 out of the 48 (2%) seawater samples were positive for Blastocystis in the Amasya and Sinop Provinces. There were two different subtypes (ST; 1 and 3) found from sequencing all of the samples from the investigated sites. Two and one PCR products were found to be positive for ST1 and ST3 from the different samples collected within the Samsun Province. Two and 4 PCR products from the Amasya Province were ST1 and ST3, respectively and only one sample from the Sinop Province was found to be positive for ST1. This is the first report to identify and report the occurrence of Blastocystis subtypes within the Black Sea of Turkey. Copyright © 2018 Elsevier B.V. All rights reserved.

  17. SAMPLE COLLECTION AND HANDLING FOR MICROBIOLOGICAL EXAMINATION OF BIOSOLIDS

    EPA Science Inventory

    The objective of this presentation is to discuss sample collection and handling methods currently in use for detection and enumeration of microorganisms in biosolids and municipal wastewater sludges. Untreated sludges and biosolids are rarely homogeneous and present a challenge ...

  18. A long-term validation of the modernised DC-ARC-OES solid-sample method.

    PubMed

    Flórián, K; Hassler, J; Förster, O

    2001-12-01

    The validation procedure based on ISO 17025 standard has been used to study and illustrate both the longterm stability of the calibration process of the DC-ARC solid sample spectrometric method and the main validation criteria of the method. In the calculation of the validation characteristics depending on the linearity(calibration), also the fulfilment of predetermining criteria such as normality and homoscedasticity was checked. In order to decide whether there are any trends in the time-variation of the analytical signal or not, also the Neumann test of trend was applied and evaluated. Finally, a comparison with similar validation data of the ETV-ICP-OES method was carried out.

  19. On the validity of the Poisson assumption in sampling nanometer-sized aerosols

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Damit, Brian E; Wu, Dr. Chang-Yu; Cheng, Mengdawn

    2014-01-01

    A Poisson process is traditionally believed to apply to the sampling of aerosols. For a constant aerosol concentration, it is assumed that a Poisson process describes the fluctuation in the measured concentration because aerosols are stochastically distributed in space. Recent studies, however, have shown that sampling of micrometer-sized aerosols has non-Poissonian behavior with positive correlations. The validity of the Poisson assumption for nanometer-sized aerosols has not been examined and thus was tested in this study. Its validity was tested for four particle sizes - 10 nm, 25 nm, 50 nm and 100 nm - by sampling from indoor air withmore » a DMA- CPC setup to obtain a time series of particle counts. Five metrics were calculated from the data: pair-correlation function (PCF), time-averaged PCF, coefficient of variation, probability of measuring a concentration at least 25% greater than average, and posterior distributions from Bayesian inference. To identify departures from Poissonian behavior, these metrics were also calculated for 1,000 computer-generated Poisson time series with the same mean as the experimental data. For nearly all comparisons, the experimental data fell within the range of 80% of the Poisson-simulation values. Essentially, the metrics for the experimental data were indistinguishable from a simulated Poisson process. The greater influence of Brownian motion for nanometer-sized aerosols may explain the Poissonian behavior observed for smaller aerosols. Although the Poisson assumption was found to be valid in this study, it must be carefully applied as the results here do not definitively prove applicability in all sampling situations.« less

  20. Comparison of PIXE and XRF analysis of airborne particulate matter samples collected on Teflon and quartz fibre filters

    NASA Astrophysics Data System (ADS)

    Chiari, M.; Yubero, E.; Calzolai, G.; Lucarelli, F.; Crespo, J.; Galindo, N.; Nicolás, J. F.; Giannoni, M.; Nava, S.

    2018-02-01

    Within the framework of research projects focusing on the sampling and analysis of airborne particulate matter, Particle Induced X-ray Emission (PIXE) and Energy Dispersive X-ray Fluorescence (ED-XRF) techniques are routinely used in many laboratories throughout the world to determine the elemental concentration of the particulate matter samples. In this work an inter-laboratory comparison of the results obtained from analysing several samples (collected on both Teflon and quartz fibre filters) using both techniques is presented. The samples were analysed by PIXE (in Florence, at the 3 MV Tandetron accelerator of INFN-LABEC laboratory) and by XRF (in Elche, using the ARL Quant'X EDXRF spectrometer with specific conditions optimized for specific groups of elements). The results from the two sets of measurements are in good agreement for all the analysed samples, thus validating the use of the ARL Quant'X EDXRF spectrometer and the selected measurement protocol for the analysis of aerosol samples. Moreover, thanks to the comparison of PIXE and XRF results on Teflon and quartz fibre filters, possible self-absorption effects due to the penetration of the aerosol particles inside the quartz fibre-filters were quantified.

  1. COLLECTING URINE SAMPLES FROM YOUNG CHILDREN FOR PESTICIDE STUDIES

    EPA Science Inventory

    To estimate pesticide exposure for young children wearing diapers, a method for collecting urine samples for analysis of pesticide metabolites is needed. To find a practical method, two possibilities were investigated: (1) analysis of expressed urine from cotton diaper inserts ...

  2. Impact of Pre-analytic Blood Sample Collection Factors on Metabolomics.

    PubMed

    Townsend, Mary K; Bao, Ying; Poole, Elizabeth M; Bertrand, Kimberly A; Kraft, Peter; Wolpin, Brian M; Clish, Clary B; Tworoger, Shelley S

    2016-05-01

    Many epidemiologic studies are using metabolomics to discover markers of carcinogenesis. However, limited data are available on the influence of pre-analytic blood collection factors on metabolite measurement. We quantified 166 metabolites in archived plasma from 423 Health Professionals Follow-up Study and Nurses' Health Study participants using liquid chromatography-tandem mass spectrometry (LC-MS). We compared multivariable-adjusted geometric mean metabolite LC-MS peak areas across fasting time, season of blood collection, and time of day of blood collection categories. The majority of metabolites (160 of 166 metabolites) had geometric mean peak areas that were within 15% comparing samples donated after fasting 9 to 12 versus ≥13 hours; greater differences were observed in samples donated after fasting ≤4 hours. Metabolite peak areas generally were similar across season of blood collection, although levels of certain metabolites (e.g., bile acids and purines/pyrimidines) tended to be different in the summer versus winter months. After adjusting for fasting status, geometric mean peak areas for bile acids and vitamins, but not other metabolites, differed by time of day of blood collection. Fasting, season of blood collection, and time of day of blood collection were not important sources of variability in measurements of most metabolites in our study. However, considering blood collection variables in the design or analysis of studies may be important for certain specific metabolites, particularly bile acids, purines/pyrimidines, and vitamins. These results may be useful for investigators formulating analysis plans for epidemiologic metabolomics studies, including determining which metabolites to a priori exclude from analyses. Cancer Epidemiol Biomarkers Prev; 25(5); 823-9. ©2016 AACR. ©2016 American Association for Cancer Research.

  3. Private practice outcomes: validated outcomes data collection in private practice.

    PubMed

    Goldstein, Jack

    2010-10-01

    Improved patient care is related to validated outcome measures requiring the collection of three distinct data types: (1) demographics; (2) patient outcome measures; and (3) physician treatment. Previous impediments to widespread data collection have been: cost, office disruption, personnel requirements, physician motivation, data integration, and security. There are currently few means to collect data to be used for collaborative analysis. We therefore developed an inexpensive, patient-centric mechanism to reduce redundant data entry, limiting cost and personnel requirements. Using an intuitive touch-screen kiosk interface program, all data elements have been captured in a private practice setting since 2000. Developed for small to medium sized offices, this is scalable to larger organizations. Questionnaire navigation is patient driven, with demographics shared with EMR and billing systems. Integration of billing and EMR with outcomes minimizes cost and personnel time. Data are deidentified locally and may be centrally shared. Since data are entered by the patients, minimal personnel costs are incurred. Physician disincentives are minimized with cost reduction, time savings and ease of use. To date, we have collected high level data on most total joint patients, with excellent patient compliance. By addressing impediments to broad application, we may enable widespread local data collection in all practice settings. Data may be shared centrally, allowing comparative effectiveness research to become a reality. Future success will require broad physician participation, uniformity of data collected, and designation of a central site for receipt of data and its collaborative comparative analysis.

  4. Methods for collection and analysis of aquatic biological and microbiological samples

    USGS Publications Warehouse

    Britton, L.J.; Greeson, P.E.

    1989-01-01

    The series of chapters on techniques describes methods used by the U.S. Geological Survey for planning and conducting water-resources investigations. The material is arranged under major subject headings called books and is further subdivided into sections and chapters. Book 5 is on laboratory analysis. Section A is on water. The unit of publication, the chapter, is limited to a narrow field of subject matter. "Methods for Collection and Analysis of Aquatic Biological and Microbiological Samples" is the fourth chapter to be published under Section A of Book 5. The chapter number includes the letter of the section.This chapter was prepared by several aquatic biologists and microbiologists of the U.S. Geological Survey to provide accurate and precise methods for the collection and analysis of aquatic biological and microbiological samples.Use of brand, firm, and trade names in this chapter is for identification purposes only and does not constitute endorsement by the U.S. Geological Survey.This chapter supersedes "Methods for Collection and Analysis of Aquatic Biological and Microbiological Samples" edited by P.E. Greeson, T.A. Ehlke, G.A. Irwin, B.W. Lium, and K.V. Slack (U.S. Geological Survey Techniques of Water-Resources Investigations, Book 5, Chapter A4, 1977) and also supersedes "A Supplement to-Methods for Collection and Analysis of Aquatic Biological and Microbiological Samples" by P.E. Greeson (U.S. Geological Survey Techniques of Water-Resources Investigations, Book 5, Chapter A4), Open-File Report 79-1279, 1979.

  5. The Psychopathy Q-Sort. Construct Validity Evidence in a Nonclinical Sample

    ERIC Educational Resources Information Center

    Fowler, Katherine A.; Lilienfeld, Scott O.

    2007-01-01

    Scant research has examined the validity of instruments that permit observer ratings of psychopathy. Using a nonclinical (undergraduate) sample, the authors examined the associations between both self- and observer ratings on a psychopathy prototype (Psychopathy Q-Sort, PQS) and widely used measures of psychopathy, antisocial behavior, and…

  6. Human blood RNA stabilization in samples collected and transported for a large biobank

    PubMed Central

    2012-01-01

    Background The Norwegian Mother and Child Cohort Study (MoBa) is a nation-wide population-based pregnancy cohort initiated in 1999, comprising more than 108.000 pregnancies recruited between 1999 and 2008. In this study we evaluated the feasibility of integrating RNA analyses into existing MoBa protocols. We compared two different blood RNA collection tube systems – the PAXgene™ Blood RNA system and the Tempus™ Blood RNA system - and assessed the effects of suboptimal blood volumes in collection tubes and of transportation of blood samples by standard mail. Endpoints to characterize the samples were RNA quality and yield, and the RNA transcript stability of selected genes. Findings High-quality RNA could be extracted from blood samples stabilized with both PAXgene and Tempus tubes. The RNA yields obtained from the blood samples collected in Tempus tubes were consistently higher than from PAXgene tubes. Higher RNA yields were obtained from cord blood (3 – 4 times) compared to adult blood with both types of tubes. Transportation of samples by standard mail had moderate effects on RNA quality and RNA transcript stability; the overall RNA quality of the transported samples was high. Some unexplained changes in gene expression were noted, which seemed to correlate with suboptimal blood volumes collected in the tubes. Temperature variations during transportation may also be of some importance. Conclusions Our results strongly suggest that special collection tubes are necessary for RNA stabilization and they should be used for establishing new biobanks. We also show that the 50,000 samples collected in the MoBa biobank provide RNA of high quality and in sufficient amounts to allow gene expression analyses for studying the association of disease with altered patterns of gene expression. PMID:22988904

  7. Demonstration/Validation of Incremental Sampling at Two Diverse Military Ranges and Development of an Incremental Sampling Tool

    DTIC Science & Technology

    2010-06-01

    Sampling (MIS)? • Technique of combining many increments of soil from a number of points within exposure area • Developed by Enviro Stat (Trademarked...Demonstrating a reliable soil sampling strategy to accurately characterize contaminant concentrations in spatially extreme and heterogeneous...into a set of decision (exposure) units • One or several discrete or small- scale composite soil samples collected to represent each decision unit

  8. Get the most out of blow hormones: validation of sampling materials, field storage and extraction techniques for whale respiratory vapour samples.

    PubMed

    Burgess, Elizabeth A; Hunt, Kathleen E; Kraus, Scott D; Rolland, Rosalind M

    2016-01-01

    Studies are progressively showing that vital physiological data may be contained in the respiratory vapour (blow) of cetaceans. Nonetheless, fundamental methodological issues need to be addressed before hormone analysis of blow can become a reliable technique. In this study, we performed controlled experiments in a laboratory setting, using known doses of pure parent hormones, to validate several technical factors that may play a crucial role in hormone analyses. We evaluated the following factors: (i) practical field storage of samples on small boats during daylong trips; (ii) efficiency of hormone extraction methods; and (iii) assay interference of different sampler types (i.e. veil nylon, nitex nylon mesh and polystyrene dish). Sampling materials were dosed with mock blow samples of known mixed hormone concentrations (progesterone, 17β-estradiol, testosterone, cortisol, aldosterone and triiodothyronine), designed to mimic endocrine profiles characteristic of pregnant females, adult males, an adrenal glucocorticoid response or a zero-hormone control (distilled H 2 O). Results showed that storage of samples in a cooler on ice preserved hormone integrity for at least 6 h ( P  = 0.18). All sampling materials and extraction methods yielded the correct relative patterns for all six hormones. However, veil and nitex mesh produced detectable assay interference (mean 0.22 ± 0.04 and 0.18 ± 0.03 ng/ml, respectively), possibly caused by some nylon-based component affecting antibody binding. Polystyrene dishes were the most efficacious sampler for accuracy and precision ( P  < 0.001), but required an ethanol rinse for improved progesterone recovery (increased 81%; P  < 0.001). Awareness of assay interference from exogenous materials is crucial to future studies. This study establishes critical groundwork to help ensure that hormones can be measured accurately in samples obtained from field collections of whale blow.

  9. [Rosenberg self-esteem scale: validation in a representative sample of Chilean adults].

    PubMed

    Rojas-Barahona, Cristian A; Zegers, Beatriz; Förster, Carla E

    2009-06-01

    Self-esteem is positively associated to the well being of people and could be a good mental health indicator. To determine the reliability and validity of the Rosenberg Self-esteem Scale in a Chilean adult sample. The instrument was applied to 473 subjects living in the Metropolitan Region of Santiago, evenly distributed according to gender, age, educational level and income. The Neugarten Life Satisfaction index (LSI-A) was also applied to the sample. Cronbach's alpha for reliability of the scale was 0.754. There was no gender bias and factor analysis grouped items into two factors (5 positive and 5 negative). The instrument had a correlation of 0.455 with the LSI-A. The Rosenberg Self-esteem Scale meets the criteria for validity and reliability of a quality instrument to measure self-esteem in Chile.

  10. Validation of the Novaco Anger Scale-Provocation Inventory (Danish) With Nonclinical, Clinical, and Offender Samples.

    PubMed

    Moeller, Stine Bjerrum; Novaco, Raymond W; Heinola-Nielsen, Vivian; Hougaard, Helle

    2016-10-01

    Anger has high prevalence in clinical and forensic settings, and it is associated with aggressive behavior and ward atmosphere on psychiatric units. Dysregulated anger is a clinical problem in Danish mental health care systems, but no anger assessment instruments have been validated in Danish. Because the Novaco Anger Scale and Provocation Inventory (NAS-PI) has been extensively validated with different clinical populations and lends itself to clinical case formulation, it was selected for translation and evaluation in the present multistudy project. Psychometric properties of the NAS-PI were investigated with samples of 477 nonclinical, 250 clinical, 167 male prisoner, and 64 male forensic participants. Anger prevalence and its relationship with other anger measures, anxiety/depression, and aggression were examined. NAS-PI was found to have high reliability, concurrent validity, and discriminant validity, and its scores discriminated the samples. High scores in the offender group demonstrated the feasibility of obtaining self-report assessments of anger with this population. Retrospective and prospective validity of the NAS were tested with the forensic patient sample regarding physically aggressive behavior in hospital. Regression analyses showed that higher scores on NAS increase the risk of having acted aggressively in the past and of acting aggressively in the future. © The Author(s) 2015.

  11. Breath-collection device for delayed breath-alcohol analysis

    DOT National Transportation Integrated Search

    1980-12-01

    The report includes the details of a study to develop, evaluate, and validate a breath collection device (BCD) for delayed breath-alcohol analysis. Primary applications of the BCD include collection of breath-alcohol samples for field surveys or for ...

  12. Evaluating the reliability, validity, acceptability, and practicality of SMS text messaging as a tool to collect research data: results from the Feeding Your Baby project.

    PubMed

    Whitford, Heather M; Donnan, Peter T; Symon, Andrew G; Kellett, Gillian; Monteith-Hodge, Ewa; Rauchhaus, Petra; Wyatt, Jeremy C

    2012-01-01

    To test the reliability, validity, acceptability, and practicality of short message service (SMS) messaging for collection of research data. The studies were carried out in a cohort of recently delivered women in Tayside, Scotland, UK, who were asked about their current infant feeding method and future feeding plans. Reliability was assessed by comparison of their responses to two SMS messages sent 1 day apart. Validity was assessed by comparison of their responses to text questions and the same question administered by phone 1 day later, by comparison with the same data collected from other sources, and by correlation with other related measures. Acceptability was evaluated using quantitative and qualitative questions, and practicality by analysis of a researcher log. Reliability of the factual SMS message gave perfect agreement. Reliabilities for the numerical question were reasonable, with κ between 0.76 (95% CI 0.56 to 0.96) and 0.80 (95% CI 0.59 to 1.00). Validity for data compared with that collected by phone within 24 h (κ =0.92 (95% CI 0.84 to 1.00)) and with health visitor data (κ =0.85 (95% CI 0.73 to 0.97)) was excellent. Correlation validity between the text responses and other related demographic and clinical measures was as expected. Participants found the method a convenient and acceptable way of providing data. For researchers, SMS text messaging provided an easy and functional method of gathering a large volume of data. In this sample and for these questions, SMS was a reliable and valid method for capturing research data.

  13. Construct Validity of the Anxiety Sensitivity Index-3 in Clinical Samples

    ERIC Educational Resources Information Center

    Kemper, Christoph J.; Lutz, Johannes; Bahr, Tobias; Ruddel, Heinz; Hock, Michael

    2012-01-01

    Using two clinical samples of patients, the presented studies examined the construct validity of the recently revised Anxiety Sensitivity Index-3 (ASI-3). Confirmatory factor analyses established a clear three-factor structure that corresponds to the postulated subdivision of the construct into correlated somatic, social, and cognitive components.…

  14. Blood venous sample collection: Recommendations overview and a checklist to improve quality.

    PubMed

    Giavarina, Davide; Lippi, Giuseppe

    2017-07-01

    The extra-analytical phases of the total testing process have substantial impact on managed care, as well as an inherent high risk of vulnerability to errors which is often greater than that of the analytical phase. The collection of biological samples is a crucial preanalytical activity. Problems or errors occurring shortly before, or soon after, this preanalytical step may impair sample quality and characteristics, or else modify the final results of testing. The standardization of fasting requirements, rest, patient position and psychological state of the patient are therefore crucial for mitigating the impact of preanalytical variability. Moreover, the quality of materials used for collecting specimens, along with their compatibility, can guarantee sample quality and persistence of chemical and physical characteristics of the analytes over time, so safeguarding the reliability of testing. Appropriate techniques and sampling procedures are effective to prevent problems such as hemolysis, undue clotting in the blood tube, draw of insufficient sample volume and modification of analyte concentration. An accurate identification of both patient and blood samples is a key priority as for other healthcare activities. Good laboratory practice and appropriate training of operators, by specifically targeting collection of biological samples, blood in particular, may greatly improve this issue, thus lowering the risk of errors and their adverse clinical consequences. The implementation of a simple and rapid check-list, including verification of blood collection devices, patient preparation and sampling techniques, was found to be effective for enhancing sample quality and reducing some preanalytical errors associated with these procedures. The use of this tool, along with implementation of objective and standardized systems for detecting non-conformities related to unsuitable samples, can be helpful for standardizing preanalytical activities and improving the quality of

  15. Enhanced Conformational Sampling Using Replica Exchange with Collective-Variable Tempering.

    PubMed

    Gil-Ley, Alejandro; Bussi, Giovanni

    2015-03-10

    The computational study of conformational transitions in RNA and proteins with atomistic molecular dynamics often requires suitable enhanced sampling techniques. We here introduce a novel method where concurrent metadynamics are integrated in a Hamiltonian replica-exchange scheme. The ladder of replicas is built with different strengths of the bias potential exploiting the tunability of well-tempered metadynamics. Using this method, free-energy barriers of individual collective variables are significantly reduced compared with simple force-field scaling. The introduced methodology is flexible and allows adaptive bias potentials to be self-consistently constructed for a large number of simple collective variables, such as distances and dihedral angles. The method is tested on alanine dipeptide and applied to the difficult problem of conformational sampling in a tetranucleotide.

  16. Enhanced Conformational Sampling Using Replica Exchange with Collective-Variable Tempering

    PubMed Central

    2015-01-01

    The computational study of conformational transitions in RNA and proteins with atomistic molecular dynamics often requires suitable enhanced sampling techniques. We here introduce a novel method where concurrent metadynamics are integrated in a Hamiltonian replica-exchange scheme. The ladder of replicas is built with different strengths of the bias potential exploiting the tunability of well-tempered metadynamics. Using this method, free-energy barriers of individual collective variables are significantly reduced compared with simple force-field scaling. The introduced methodology is flexible and allows adaptive bias potentials to be self-consistently constructed for a large number of simple collective variables, such as distances and dihedral angles. The method is tested on alanine dipeptide and applied to the difficult problem of conformational sampling in a tetranucleotide. PMID:25838811

  17. Development and Validation of Pathogen Environmental Monitoring Programs for Small Cheese Processing Facilities.

    PubMed

    Beno, Sarah M; Stasiewicz, Matthew J; Andrus, Alexis D; Ralyea, Robert D; Kent, David J; Martin, Nicole H; Wiedmann, Martin; Boor, Kathryn J

    2016-12-01

    Pathogen environmental monitoring programs (EMPs) are essential for food processing facilities of all sizes that produce ready-to-eat food products exposed to the processing environment. We developed, implemented, and evaluated EMPs targeting Listeria spp. and Salmonella in nine small cheese processing facilities, including seven farmstead facilities. Individual EMPs with monthly sample collection protocols were designed specifically for each facility. Salmonella was detected in only one facility, with likely introduction from the adjacent farm indicated by pulsed-field gel electrophoresis data. Listeria spp. were isolated from all nine facilities during routine sampling. The overall Listeria spp. (other than Listeria monocytogenes ) and L. monocytogenes prevalences in the 4,430 environmental samples collected were 6.03 and 1.35%, respectively. Molecular characterization and subtyping data suggested persistence of a given Listeria spp. strain in seven facilities and persistence of L. monocytogenes in four facilities. To assess routine sampling plans, validation sampling for Listeria spp. was performed in seven facilities after at least 6 months of routine sampling. This validation sampling was performed by independent individuals and included collection of 50 to 150 samples per facility, based on statistical sample size calculations. Two of the facilities had a significantly higher frequency of detection of Listeria spp. during the validation sampling than during routine sampling, whereas two other facilities had significantly lower frequencies of detection. This study provides a model for a science- and statistics-based approach to developing and validating pathogen EMPs.

  18. Toward Lower Organic Environments in Astromaterial Sample Curation for Diverse Collections

    NASA Technical Reports Server (NTRS)

    Allton, J. H.; Allen, C. C.; Burkett, P. J.; Calaway, M. J.; Oehler, D. Z.

    2012-01-01

    Great interest was taken during the frenzied pace of the Apollo lunar sample return to achieve and monitor organic cleanliness. Yet, the first mission resulted in higher organic contamination to samples than desired. But improvements were accomplished by Apollo 12 [1]. Quarantine complicated the goal of achieving organic cleanliness by requiring negative pressure glovebox containment environments, proximity of animal, plant and microbial organic sources, and use of organic sterilants in protocols. A special low organic laboratory was set up at University of California Berkeley (UCB) to cleanly subdivide a subset of samples [2, 3, 4]. Nevertheless, the basic approach of handling rocks and regolith inside of a positive pressure stainless steel glovebox and restrict-ing the tool and container materials allowed in the gloveboxes was established by the last Apollo sample re-turn. In the last 40 years, the collections have grown to encompass Antarctic meteorites, Cosmic Dust, Genesis solar wind, Stardust comet grains and Hayabusa asteroid grains. Each of these collections have unique curation requirements for organic contamination monitor-ing and control. Here is described some changes allowed by improved technology or driven by changes in environmental regulations and economy, concluding with comments on organic witness wafers. Future sample return missions (OSIRIS-Rex; Mars; comets) will require extremely low levels of organic contamination in spacecraft collection and thus similarly low levels in curation. JSC Curation is undertaking a program to document organic baseline levels in current operations and devise ways to reduce those levels.

  19. The use of Vacutainer tubes for collection of soil samples for helium analysis

    USGS Publications Warehouse

    Hinkle, Margaret E.; Kilburn, James E.

    1979-01-01

    Measurements of the helium concentration of soil samples collected and stored in Vacutainer-brand evacuated glass tubes show that Vacutainers are reliable containers for soil collection. Within the limits of reproducibility, helium content of soils appears to be independent of variations in soil temperature, barometric pressure, and quantity of soil moisture present in the sample.

  20. Variation in aluminum, iron, and particle concentrations in oxic groundwater samples collected by use of tangential-flow ultrafiltration with low-flow sampling

    NASA Astrophysics Data System (ADS)

    Szabo, Zoltan; Oden, Jeannette H.; Gibs, Jacob; Rice, Donald E.; Ding, Yuan

    2002-02-01

    Particulates that move with ground water and those that are artificially mobilized during well purging could be incorporated into water samples during collection and could cause trace-element concentrations to vary in unfiltered samples, and possibly in filtered samples (typically 0.45-um (micron) pore size) as well, depending on the particle-size fractions present. Therefore, measured concentrations may not be representative of those in the aquifer. Ground water may contain particles of various sizes and shapes that are broadly classified as colloids, which do not settle from water, and particulates, which do. In order to investigate variations in trace-element concentrations in ground-water samples as a function of particle concentrations and particle-size fractions, the U.S. Geological Survey, in cooperation with the U.S. Air Force, collected samples from five wells completed in the unconfined, oxic Kirkwood-Cohansey aquifer system of the New Jersey Coastal Plain. Samples were collected by purging with a portable pump at low flow (0.2-0.5 liters per minute and minimal drawdown, ideally less than 0.5 foot). Unfiltered samples were collected in the following sequence: (1) within the first few minutes of pumping, (2) after initial turbidity declined and about one to two casing volumes of water had been purged, and (3) after turbidity values had stabilized at less than 1 to 5 Nephelometric Turbidity Units. Filtered samples were split concurrently through (1) a 0.45-um pore size capsule filter, (2) a 0.45-um pore size capsule filter and a 0.0029-um pore size tangential-flow filter in sequence, and (3), in selected cases, a 0.45-um and a 0.05-um pore size capsule filter in sequence. Filtered samples were collected concurrently with the unfiltered sample that was collected when turbidity values stabilized. Quality-assurance samples consisted of sequential duplicates (about 25 percent) and equipment blanks. Concentrations of particles were determined by light scattering.

  1. Variation in aluminum, iron, and particle concentrations in oxic ground-water samples collected by use of tangential-flow ultrafiltration with low-flow sampling

    USGS Publications Warehouse

    Szabo, Z.; Oden, J.H.; Gibs, J.; Rice, D.E.; Ding, Y.; ,

    2001-01-01

    Particulates that move with ground water and those that are artificially mobilized during well purging could be incorporated into water samples during collection and could cause trace-element concentrations to vary in unfiltered samples, and possibly in filtered samples (typically 0.45-um (micron) pore size) as well, depending on the particle-size fractions present. Therefore, measured concentrations may not be representative of those in the aquifer. Ground water may contain particles of various sizes and shapes that are broadly classified as colloids, which do not settle from water, and particulates, which do. In order to investigate variations in trace-element concentrations in ground-water samples as a function of particle concentrations and particle-size fractions, the U.S. Geological Survey, in cooperation with the U.S. Air Force, collected samples from five wells completed in the unconfined, oxic Kirkwood-Cohansey aquifer system of the New Jersey Coastal Plain. Samples were collected by purging with a portable pump at low flow (0.2-0.5 liters per minute and minimal drawdown, ideally less than 0.5 foot). Unfiltered samples were collected in the following sequence: (1) within the first few minutes of pumping, (2) after initial turbidity declined and about one to two casing volumes of water had been purged, and (3) after turbidity values had stabilized at less than 1 to 5 Nephelometric Turbidity Units. Filtered samples were split concurrently through (1) a 0.45-um pore size capsule filter, (2) a 0.45-um pore size capsule filter and a 0.0029-um pore size tangential-flow filter in sequence, and (3), in selected cases, a 0.45-um and a 0.05-um pore size capsule filter in sequence. Filtered samples were collected concurrently with the unfiltered sample that was collected when turbidity values stabilized. Quality-assurance samples consisted of sequential duplicates (about 25 percent) and equipment blanks. Concentrations of particles were determined by light scattering

  2. A Pilot Psychometric Study on the Validation of the Older Women’s Non-Medical Stress Scale (OWN-MSS) on an Ethnically Diverse Sample

    PubMed Central

    Laganà, Luciana; Prilutsky, Roxanne R.

    2016-01-01

    Introduction Older women often experience various types of stressors, including the death of a spouse and associated financial stress (often with a lack of social support), emotional stress due to factors such as caregiving and being single, and the challenges of the aging process. These circumstances could produce or aggravate anxious symptomatology that can in turn compound the negative effects of aging. A brief scale of perceived stress that is not confounded with health status and covers multiple culturally relevant potential stressors is needed for quick use in busy medical settings. Aim To assess the reliability and the validity of an original stress scale designed to measure perceptions of stress beyond health status in a non-clinical convenience sample of community-dwelling older women. Method In this cross-sectional pilot investigation, via conducting item-total correlations and correlational tests of validity, we studied the psychometric properties of our measure using data from volunteer older subjects (mainly low-income and from non-Caucasian backgrounds). The domains covered by the nine items of the tool were selected based on a literature review of common stressors experienced by older adults, especially by older women. Data were collected face-to-face using a demographic list, a well-established depression measure, a brief posttraumatic stress disorder (PTSD) screener, and our 9-item stress tool. Primary outcomes: reliability and validity of the scale of older women’s non-medical stress. Secondary outcomes: demographic characteristics of the sample and correlations between stress items. Results Based on our sample of older women (N=40, mean age 71 years), good internal consistency between the items of the stress scale was found (Cronbach’s a=.66). The findings of the data analyses also revealed that our psychometric tool has good convergent validity with the PTSD screener (r=.53). Moreover, in contrast with most other stress tools, it has strong

  3. PIXE Analysis of Aerosol and Soil Samples Collected in the Adirondack Mountains

    NASA Astrophysics Data System (ADS)

    Yoskowitz, Joshua; Ali, Salina; Nadareski, Benjamin; Labrake, Scott; Vineyard, Michael

    2014-09-01

    We have performed an elemental analysis of aerosol and soil samples collected at Piseco Lake in Upstate New York using proton induced X-ray emission spectroscopy (PIXE). This work is part of a systematic study of airborne pollution in the Adirondack Mountains. Of particular interest is the sulfur content that can contribute to acid rain, a well-documented problem in the Adirondacks. We used a nine-stage cascade impactor to collect the aerosol samples near Piseco Lake and distribute the particulate matter onto Kapton foils by particle size. The soil samples were also collected at Piseco Lake and pressed into cylindrical pellets for experimentation. PIXE analysis of the aerosol and soil samples were performed with 2.2-MeV proton beams from the 1.1-MV Pelletron accelerator in the Union College Ion-Beam Analysis Laboratory. There are higher concentrations of sulfur at smaller particle sizes (0.25-1 μm), suggesting that it could be suspended in the air for days and originate from sources very far away. Other elements with significant concentrations peak at larger particle sizes (1-4 μm) and are found in the soil samples, suggesting that these elements could originate in the soil. The PIXE analysis will be described and the resulting data will be presented.

  4. Determination of methylmercury in marine biota samples with advanced mercury analyzer: method validation.

    PubMed

    Azemard, Sabine; Vassileva, Emilia

    2015-06-01

    In this paper, we present a simple, fast and cost-effective method for determination of methyl mercury (MeHg) in marine samples. All important parameters influencing the sample preparation process were investigated and optimized. Full validation of the method was performed in accordance to the ISO-17025 (ISO/IEC, 2005) and Eurachem guidelines. Blanks, selectivity, working range (0.09-3.0ng), recovery (92-108%), intermediate precision (1.7-4.5%), traceability, limit of detection (0.009ng), limit of quantification (0.045ng) and expanded uncertainty (15%, k=2) were assessed. Estimation of the uncertainty contribution of each parameter and the demonstration of traceability of measurement results was provided as well. Furthermore, the selectivity of the method was studied by analyzing the same sample extracts by advanced mercury analyzer (AMA) and gas chromatography-atomic fluorescence spectrometry (GC-AFS). Additional validation of the proposed procedure was effectuated by participation in the IAEA-461 worldwide inter-laboratory comparison exercises. Copyright © 2014 Elsevier Ltd. All rights reserved.

  5. Advanced Curation Activities at NASA: Implications for Astrobiological Studies of Future Sample Collections

    NASA Technical Reports Server (NTRS)

    McCubbin, F. M.; Evans, C. A.; Fries, M. D.; Harrington, A. D.; Regberg, A. B.; Snead, C. J.; Zeigler, R. A.

    2017-01-01

    The Astromaterials Acquisition and Curation Office (henceforth referred to herein as NASA Curation Office) at NASA Johnson Space Center (JSC) is responsible for curating all of NASA's extraterrestrial samples. Under the governing document, NASA Policy Directive (NPD) 7100.10F JSC is charged with curation of all extraterrestrial material under NASA control, including future NASA missions. The Directive goes on to define Curation as including documentation, preservation, preparation, and distribution of samples for re-search, education, and public outreach. Here we briefly describe NASA's astromaterials collections and our ongoing efforts related to enhancing the utility of our current collections as well as our efforts to prepare for future sample return missions. We collectively refer to these efforts as advanced curation.

  6. Evaluating the reliability, validity, acceptability, and practicality of SMS text messaging as a tool to collect research data: results from the Feeding Your Baby project

    PubMed Central

    Donnan, Peter T; Symon, Andrew G; Kellett, Gillian; Monteith-Hodge, Ewa; Rauchhaus, Petra; Wyatt, Jeremy C

    2012-01-01

    Objective To test the reliability, validity, acceptability, and practicality of short message service (SMS) messaging for collection of research data. Materials and methods The studies were carried out in a cohort of recently delivered women in Tayside, Scotland, UK, who were asked about their current infant feeding method and future feeding plans. Reliability was assessed by comparison of their responses to two SMS messages sent 1 day apart. Validity was assessed by comparison of their responses to text questions and the same question administered by phone 1 day later, by comparison with the same data collected from other sources, and by correlation with other related measures. Acceptability was evaluated using quantitative and qualitative questions, and practicality by analysis of a researcher log. Results Reliability of the factual SMS message gave perfect agreement. Reliabilities for the numerical question were reasonable, with κ between 0.76 (95% CI 0.56 to 0.96) and 0.80 (95% CI 0.59 to 1.00). Validity for data compared with that collected by phone within 24 h (κ =0.92 (95% CI 0.84 to 1.00)) and with health visitor data (κ =0.85 (95% CI 0.73 to 0.97)) was excellent. Correlation validity between the text responses and other related demographic and clinical measures was as expected. Participants found the method a convenient and acceptable way of providing data. For researchers, SMS text messaging provided an easy and functional method of gathering a large volume of data. Conclusion In this sample and for these questions, SMS was a reliable and valid method for capturing research data. PMID:22539081

  7. Methods for collection and analysis of aquatic biological and microbiological samples

    USGS Publications Warehouse

    Greeson, Phillip E.; Ehlke, T.A.; Irwin, G.A.; Lium, B.W.; Slack, K.V.

    1977-01-01

    Chapter A4 contains methods used by the U.S. Geological Survey to collect, preserve, and analyze waters to determine their biological and microbiological properties. Part 1 discusses biological sampling and sampling statistics. The statistical procedures are accompanied by examples. Part 2 consists of detailed descriptions of more than 45 individual methods, including those for bacteria, phytoplankton, zooplankton, seston, periphyton, macrophytes, benthic invertebrates, fish and other vertebrates, cellular contents, productivity, and bioassays. Each method is summarized, and the application, interferences, apparatus, reagents, collection, analysis, calculations, reporting of results, precision and references are given. Part 3 consists of a glossary. Part 4 is a list of taxonomic references.

  8. An automation-assisted generic approach for biological sample preparation and LC-MS/MS method validation.

    PubMed

    Zhang, Jie; Wei, Shimin; Ayres, David W; Smith, Harold T; Tse, Francis L S

    2011-09-01

    Although it is well known that automation can provide significant improvement in the efficiency of biological sample preparation in quantitative LC-MS/MS analysis, it has not been widely implemented in bioanalytical laboratories throughout the industry. This can be attributed to the lack of a sound strategy and practical procedures in working with robotic liquid-handling systems. Several comprehensive automation assisted procedures for biological sample preparation and method validation were developed and qualified using two types of Hamilton Microlab liquid-handling robots. The procedures developed were generic, user-friendly and covered the majority of steps involved in routine sample preparation and method validation. Generic automation procedures were established as a practical approach to widely implement automation into the routine bioanalysis of samples in support of drug-development programs.

  9. Starting a European Space Agency Sample Analogue Collection for Robotic Exploration Missions

    NASA Astrophysics Data System (ADS)

    Smith, C. L.; Mavris, C.; Michalski, J. R.; Rumsey, M. S.; Russell, S. S.; Jones, C.; Schroeven-Deceuninck, H.

    2015-12-01

    The Natural History Museum is working closely with the European Space Agency (ESA) and the UK Space Agency to develop a European collection of analogue materials with appropriate physical/mechanical and chemical (mineralogical) properties which can support the development and verification of both spacecraft and scientific systems for potential science and exploration missions to Phobos/Deimos, Mars, C-type asteroids and the Moon. As an ESA Collection it will be housed at the ESA Centre based at Harwell, UK. The "ESA Sample Analogues Collection" will be composed of both natural and artificial materials chosen to (as closely as possible) replicate the surfaces and near-surfaces of different Solar System target bodies of exploration interest. The analogue samples will be fully characterised in terms of both their physical/mechanical properties (compressive strength, bulk density, grain shape, grain size, cohesion and angle of internal friction) and their chemical/mineralogical properties (texture, modal mineralogy, bulk chemical composition - major, minor and trace elements and individual mineralogical compositions). The Collection will be fully curated to international standards including implementation of a user-friendly database and will be available for use by engineers and scientists across the UK and Europe. Enhancement of the initial Collection will be possible through collaborations with other ESA and UK Space Agency supported activities, such as the acquisition of new samples during field trials.

  10. The U.S. Geological Survey Geologic Collections Management System (GCMS)—A master catalog and collections management plan for U.S. Geological Survey geologic samples and sample collections

    USGS Publications Warehouse

    ,

    2015-01-01

    The general consideration for implementation of the GCMS is that all active USGS geologic sample repositories will form the core of GCMS and that participating science centers will develop procedures based on proposed GCMS methodologies. The GCMS is a collective resource for the entire USGS community and the users who discover the geologic materials kept in these repositories and seek to access them.

  11. Improving the quality of adult mortality data collected in demographic surveys: validation study of a new siblings' survival questionnaire in Niakhar, Senegal.

    PubMed

    Helleringer, Stéphane; Pison, Gilles; Masquelier, Bruno; Kanté, Almamy Malick; Douillot, Laetitia; Duthé, Géraldine; Sokhna, Cheikh; Delaunay, Valérie

    2014-05-01

    In countries with limited vital registration, adult mortality is frequently estimated using siblings' survival histories (SSHs) collected during Demographic and Health Surveys (DHS). These data are affected by reporting errors. We developed a new SSH questionnaire, the siblings' survival calendar (SSC). It incorporates supplementary interviewing techniques to limit omissions of siblings and uses an event history calendar to improve reports of dates and ages. We hypothesized that the SSC would improve the quality of adult mortality data. We conducted a retrospective validation study among the population of the Niakhar Health and Demographic Surveillance System in Senegal. We randomly assigned men and women aged 15-59 y to an interview with either the DHS questionnaire or the SSC. We compared SSHs collected in each group to prospective data on adult mortality collected in Niakhar. The SSC reduced respondents' tendency to round reports of dates and ages to the nearest multiple of five or ten ("heaping"). The SSC also had higher sensitivity in recording adult female deaths: among respondents whose sister(s) had died at an adult age in the past 15 y, 89.6% reported an adult female death during SSC interviews versus 75.6% in DHS interviews (p = 0.027). The specificity of the SSC was similar to that of the DHS questionnaire, i.e., it did not increase the number of false reports of deaths. However, the SSC did not improve the reporting of adult deaths among the brothers of respondents. Study limitations include sample selectivity, limited external validity, and multiple testing. The SSC has the potential to collect more accurate SSHs than the questionnaire used in DHS. Further research is needed to assess the effects of the SSC on estimates of adult mortality rates. Additional validation studies should be conducted in different social and epidemiological settings. Controlled-Trials.com ISRCTN06849961

  12. DEVELOPMENT OF A TAMPER RESISTANT/INDICATING AEROSOL COLLECTION SYSTEM FOR ENVIRONMENTAL SAMPLING AT BULK HANDLING FACILITIES

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Sexton, L.

    2012-06-06

    Environmental sampling has become a key component of International Atomic Energy Agency (IAEA) safeguards approaches since its approval for use in 1996. Environmental sampling supports the IAEA's mission of drawing conclusions concerning the absence of undeclared nuclear material or nuclear activities in a Nation State. Swipe sampling is the most commonly used method for the collection of environmental samples from bulk handling facilities. However, augmenting swipe samples with an air monitoring system, which could continuously draw samples from the environment of bulk handling facilities, could improve the possibility of the detection of undeclared activities. Continuous sampling offers the opportunity tomore » collect airborne materials before they settle onto surfaces which can be decontaminated, taken into existing duct work, filtered by plant ventilation, or escape via alternate pathways (i.e. drains, doors). Researchers at the Savannah River National Laboratory and Oak Ridge National Laboratory have been working to further develop an aerosol collection technology that could be installed at IAEA safeguarded bulk handling facilities. The addition of this technology may reduce the number of IAEA inspector visits required to effectively collect samples. The principal sample collection device is a patented Aerosol Contaminant Extractor (ACE) which utilizes electrostatic precipitation principles to deposit particulates onto selected substrates. Recent work has focused on comparing traditional swipe sampling to samples collected via an ACE system, and incorporating tamper resistant and tamper indicating (TRI) technologies into the ACE system. Development of a TRI-ACE system would allow collection of samples at uranium/plutonium bulk handling facilities in a manner that ensures sample integrity and could be an important addition to the international nuclear safeguards inspector's toolkit. This work was supported by the Next Generation Safeguards Initiative (NGSI

  13. The Brief Negative Symptom Scale (BNSS): Independent validation in a large sample of Italian patients with schizophrenia.

    PubMed

    Mucci, A; Galderisi, S; Merlotti, E; Rossi, A; Rocca, P; Bucci, P; Piegari, G; Chieffi, M; Vignapiano, A; Maj, M

    2015-07-01

    The Brief Negative Symptom Scale (BNSS) was developed to address the main limitations of the existing scales for the assessment of negative symptoms of schizophrenia. The initial validation of the scale by the group involved in its development demonstrated good convergent and discriminant validity, and a factor structure confirming the two domains of negative symptoms (reduced emotional/verbal expression and anhedonia/asociality/avolition). However, only relatively small samples of patients with schizophrenia were investigated. Further independent validation in large clinical samples might be instrumental to the broad diffusion of the scale in clinical research. The present study aimed to examine the BNSS inter-rater reliability, convergent/discriminant validity and factor structure in a large Italian sample of outpatients with schizophrenia. Our results confirmed the excellent inter-rater reliability of the BNSS (the intraclass correlation coefficient ranged from 0.81 to 0.98 for individual items and was 0.98 for the total score). The convergent validity measures had r values from 0.62 to 0.77, while the divergent validity measures had r values from 0.20 to 0.28 in the main sample (n=912) and in a subsample without clinically significant levels of depression and extrapyramidal symptoms (n=496). The BNSS factor structure was supported in both groups. The study confirms that the BNSS is a promising measure for quantifying negative symptoms of schizophrenia in large multicenter clinical studies. Copyright © 2015 Elsevier Masson SAS. All rights reserved.

  14. Validation of a new HPV self-sampling device for cervical cancer screening: The Cervical and Self-Sample In Screening (CASSIS) study.

    PubMed

    El-Zein, Mariam; Bouten, Sheila; Louvanto, Karolina; Gilbert, Lucy; Gotlieb, Walter; Hemmings, Robert; Behr, Marcel A; Franco, Eduardo L

    2018-04-17

    We compared the self-sampling performance of the newly designed HerSwab™ device with a physician-collected cervical sample and another self-sample using the cobas® PCR Female swab for the detection of cervical intraepithelial neoplasia (CIN) and cancer. Women referred for colposcopy at McGill University affiliated hospital clinics collected two consecutive self-samples, one with HerSwab™ and one with cobas® swab, after receiving instructions. The order of sampling was randomized. The colposcopist then collected a cervical sample and conducted a colposcopic examination. Samples were tested for human papillomavirus (HPV) DNA. Sensitivity and specificity to detect CIN2+ and respective 95% confidence intervals (CI) were calculated to compare sampling approaches. The HPV testing agreement between samples was measured using the Kappa statistic. Of 1217 women enrolled, 1076 had complete results for HPV and cytology; 148 (13.8%) had CIN1, 147 (13.7%) had CIN2/3, and 5 (0.5%) had cancer. There was very good agreement between methods for HPV detection (HerSwab™ versus physician: kappa=0.84; cobas® swabs versus physician: kappa=0.81; HerSwab™ versus cobas® swabs: kappa=0.87). The sensitivity of HPV detection for CIN2+ was 87.6% (95%CI: 79.8-93.2) with self-sampling using HerSwab™, 88.6% (95%CI: 80.9-94.0) with self-sampling using the cobas® swab, and 92.4% (95%CI: 85.5-96.7) with physician sampling. Corresponding estimates of specificity were 58.1% (95%CI: 54.1-62.1), 55.0% (95%CI: 50.9-59.0) and 58.7% (95%CI: 54.6-62.6). Cytology (ASC-US or more severe) done on the physician-collected specimen was 80.2% (95%CI: 70.8-87.6) sensitive and 61.4% (95%CI: 57.2-65.5) specific for CIN2+. The HerSwab™ had good agreement with physician sampling in detecting HPV, and adequate performance in detecting high-grade lesions among women referred to colposcopy for abnormal cytology. Copyright © 2018 Elsevier Inc. All rights reserved.

  15. A Tool for Comparative Collection Analysis: Conducting a Shelflist Sample to Construct a Collection Profile.

    ERIC Educational Resources Information Center

    Paskoff, Beth M.; Perrault, Anna H.

    1990-01-01

    Describes a project that examined a random sample of 5 percent of a shelflist to provide detailed information about the distribution of imprints according to age and language, percentage of duplication, and distribution of serial and monographic formats. It is concluded that the resulting collection profile provides a multidimensional, quantified…

  16. Sample collection of ash and burned soils from the October 2007 southern California Wildfires

    USGS Publications Warehouse

    Hoefen, Todd M.; Kokaly, Raymond F.; Martin, Deborah A.; Rochester, Carlton J.; Plumlee, Geoffrey S.; Mendez, Greg; Reichard, Eric G.; Fisher, Robert N.

    2009-01-01

    Between November 2 through 9, 2007 scientists from the U.S. Geological Survey (USGS) collected samples of ash and burned soils from 28 sites in six areas burned as a result of the Southern California wildfires of October 2007, including the Harris, Witch, Santiago, Ammo, Canyon, and Grass Valley Fires. The primary goal of this sampling and analysis effort was to understand how differences in ash and burned soil composition relate to vegetation type, underlying bedrock geology, burn intensity, and residential versus wildland. Sampling sites were chosen with the input of local experts from the USGS Water Resources and Biological Resources Disciplines to help understand possible effects of the fires on water supplies, ecosystems, and endangered species. The sampling was also carried out in conjunction with detailed field analysis of the spectral reflectance characteristics of the ash, so that chemical and mineralogical characteristics of the field samples could be used to help interpret data collected as part of an airborne, hyperspectral remote-sensing survey of several of the burned areas in mid-late November, 2007.This report presents an overview of the field sampling methodologies used to collect the samples, includes representative photos of the sites sampled, and summarizes important characteristics of each of the collection sites. In this report we use the term “ash” to refer collectively to white mineral ash, which results from full combustion of vegetation and black charred organic matter from partial combustion of vegetation or other materials. These materials were found to be intermingled as a deposited residue on the soil surface following the Southern California fires of 2007.

  17. Convergent Validity Evidence regarding the Validity of the Chilean Standards-Based Teacher Evaluation System

    ERIC Educational Resources Information Center

    Santelices, Maria Veronica; Taut, Sandy

    2011-01-01

    This paper describes convergent validity evidence regarding the mandatory, standards-based Chilean national teacher evaluation system (NTES). The study examined whether NTES identifies--and thereby rewards or punishes--the "right" teachers as high- or low-performing. We collected in-depth teaching performance data on a sample of 58…

  18. Portable Automation of Static Chamber Sample Collection for Quantifying Soil Gas Flux

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Davis, Morgan P.; Groh, Tyler A.; Parkin, Timothy B.

    Quantification of soil gas flux using the static chamber method is labor intensive. The number of chambers that can be sampled is limited by the spacing between chambers and the availability of trained research technicians. An automated system for collecting gas samples from chambers in the field would eliminate the need for personnel to return to the chamber during a flux measurement period and would allow a single technician to sample multiple chambers simultaneously. This study describes Chamber Automated Sampling Equipment (FluxCASE) to collect and store chamber headspace gas samples at assigned time points for the measurement of soil gasmore » flux. The FluxCASE design and operation is described, and the accuracy and precision of the FluxCASE system is evaluated. In laboratory measurements of nitrous oxide (N2O), carbon dioxide (CO2), and methane (CH4) concentrations of a standardized gas mixture, coefficients of variation associated with automated and manual sample collection were comparable, indicating no loss of precision. In the field, soil gas fluxes measured from FluxCASEs were in agreement with manual sampling for both N2O and CO2. Slopes of regression equations were 1.01 for CO2 and 0.97 for N2O. The 95% confidence limits of the slopes of the regression lines included the value of one, indicating no bias. Additionally, an expense analysis found a cost recovery ranging from 0.6 to 2.2 yr. Implementing the FluxCASE system is an alternative to improve the efficiency of the static chamber method for measuring soil gas flux while maintaining the accuracy and precision of manual sampling.« less

  19. Validation, residue analysis, and risk assessment of fipronil and flonicamid in cotton (Gossypium sp.) samples and soil.

    PubMed

    Chawla, Suchi; Gor, Hetal N; Patel, Hemlatta K; Parmar, Kaushik D; Patel, Anil R; Shukla, Varsha; Ilyas, Mohammad; Parsai, Satish K; Somashekar; Meena, Roop Singh; Shah, Paresh G

    2018-05-04

    Cotton crop is highly susceptible to attack by sucking pests. Being an important oilseed and feed crop, it is essential to monitor the pesticides and ensure health protection at consumer level. Therefore, a method was validated to estimate fipronil and flonicamid in various cotton samples and risk assessment was performed. Contamination of oil in the extracts from the various oil seeds and cake samples is a major problem as this oil contaminates the column and interferes with the detection of pesticides. The present manuscript for the first time describes successful analysis of the pesticides from various cotton samples including cotton oil, seed, and cake. Quick, easy, cheap, effective, rugged, and safe (QuEChERS)-based methods were validated for estimation of fipronil and flonicamid in cotton samples and in soil by LC-MS/MS. Recoveries were within the acceptable range of 70-120% with relative standard deviation ≤ 20% and HorRat values < 0.3-1.3. R 2 was > 0.99. Matrix effects of 150 and 13.5% were observed for fipronil and flonicamid, respectively, in cotton leaves. Limits of quantitation (LOQs) were in the range of 0.0004 to 0.004 mg kg -1 for fipronil and flonicamid. Cotton samples collected from a field study at different locations were analyzed. Half-life ranged from 2.2 to 5.8 for fipronil and 4.6 to 7.0 days for flonicamid. A pre-harvest interval of 33 days is suggested. The risk assessment studies at maximum residue level values showed HQ < 1 at pre-harvest interval (PHI). The methods being short and easy can be extended to estimate more types of pesticides in different oilseeds. Following a PHI of 33 days, fipronil and flonicamid can be used on cotton at standard dose. As the levels of fipronil and flonicamid were below determination limit in all the soils, the environmental risk is negligible.

  20. A comparison of human papillomavirus testing of clinician-collected and self-collected samples during follow-up after screen-and-treat.

    PubMed

    Taylor, Sylvia; Wang, Chunhui; Wright, Thomas C; Denny, Lynette; Kuhn, Louise

    2011-08-15

    Screen-and-treat cervical cancer prevention programs based on high-risk human papillomavirus (HPV) testing and cryotherapy have been shown to be effective in resource-limited settings. However, because cryotherapy is not 100% effective, follow-up is needed after treatment to detect post-treatment failures. We compared the test performances of high-risk HPV testing (Hybrid Capture 2) using self-collected and clinician-collected samples as well as cervical cytology for identifying cervical intraepithelial neoplasia grades 2 or 3 or invasive cervical cancer (CIN2+) among women who did (n=812) and did not (n=1858) undergo cryotherapy in a South African screen-and-treat trial. At 6 months after enrolment (and after cryotherapy, if performed), women were tested using all three screening methods and then underwent colposcopy/biopsy. A predefined subset of women (n=1,455) had extended follow-up with colposcopy/biopsy at 12 months. A total of 33 and 91 cases of CIN2+ were detected among treated and untreated women, respectively. The sensitivity of HPV testing using clinician-collected samples and cervical cytology did not differ by treatment status. HPV testing of clinician-collected samples detected the most cases of CIN2+ among both treated (85%) and untreated (91%) women (p=0.31). Cytology (at a cutoff of atypical squamous cells of undetermined significance or greater) detected 76% of cases among both treated and untreated women. However, the sensitivity of HPV testing using self-collected samples was significantly lower among treated versus untreated women (55% vs. 78%, p=0.01). HPV testing using self-collected vaginal specimens may be useful in primary screening but performs poorly for detecting post-treatment failures. Copyright © 2010 UICC.

  1. Adaptation and Validation of the Sexual Assertiveness Scale (SAS) in a Sample of Male Drug Users.

    PubMed

    Vallejo-Medina, Pablo; Sierra, Juan Carlos

    2015-04-21

    The aim of the present study was to adapt and validate the Sexual Assertiveness Scale (SAS) in a sample of male drug users. A sample of 326 male drug users and 322 non-clinical males was selected by cluster sampling and convenience sampling, respectively. Results showed that the scale had good psychometric properties and adequate internal consistency reliability (Initiation = .66, Refusal = .74 and STD-P = .79). An evaluation of the invariance showed strong factor equivalence between both samples. A high and moderate effect of Differential Item Functioning was only found in items 1 and 14 (∆R 2 Nagelkerke = .076 and .037, respectively). We strongly recommend not using item 1 if the goal is to compare the scores of both groups, otherwise the comparison will be biased. Correlations obtained between the CSFQ-14 and the safe sex ratio and the SAS subscales were significant (CI = 95%) and indicated good concurrent validity. Scores of male drug users were similar to those of non-clinical males. Therefore, the adaptation of the SAS to drug users provides enough guarantees for reliable and valid use in both clinical practice and research, although care should be taken with item 1.

  2. Stardust Sample Collection at Wild 2 and Its Preliminary Examination

    NASA Technical Reports Server (NTRS)

    Tsou, P.; Brownlee, D. E.; Hoerz, F.; Newburn, R. L.; Sandford, S. A.; Sekanina, Z.; Zolensky, M. E.

    2004-01-01

    The primary objective of STARDUST is to collect coma samples from 81P/Wild 2. This was made on January 2, 2004. Before the encounter three significant model predictions existed for the number and size of samples to be captured. Three investigations during the Wild 2 encounter (Dust Flux Monitor, Comet and Interstellar Dust Analyzer and Dynamic Science) made in situ measurements of the dust. Spectacular images were captured of the Wild 2 nucleus and dust jets. This abstract compares the model predictions with the in situ measurements and Wild 2 images and assesses the likely samples to be returned for analysis on January 15, 2006. To give some lead time for sample analysts to prepare for the analyses of the returned samples, the organization of the Preliminary Examination is presented.

  3. Methods for collecting algal samples as part of the National Water-Quality Assessment Program

    USGS Publications Warehouse

    Porter, Stephen D.; Cuffney, Thomas F.; Gurtz, Martin E.; Meador, Michael R.

    1993-01-01

    Benthic algae (periphyton) and phytoplankton communities are characterized in the U.S. Geological Survey's National Water-Quality Assessment Program as part of an integrated physical, chemical, and biological assessment of the Nation's water quality. This multidisciplinary approach provides multiple lines of evidence for evaluating water-quality status and trends, and for refining an understanding of the factors that affect water-quality conditions locally, regionally, and nationally. Water quality can be characterized by evaluating the results of qualitative and quantitative measurements of the algal community. Qualitative periphyton samples are collected to develop of list of taxa present in the sampling reach. Quantitative periphyton samples are collected to measure algal community structure within selected habitats. These samples of benthic algal communities are collected from natural substrates, using the sampling methods that are most appropriate for the habitat conditions. Phytoplankton samples may be collected in large nonwadeable streams and rivers to meet specific program objectives. Estimates of algal biomass (chlorophyll content and ash-free dry mass) also are optional measures that may be useful for interpreting water-quality conditions. A nationally consistent approach provides guidance on site, reach, and habitat selection, as well as information on methods and equipment for qualitative and quantitative sampling. Appropriate quality-assurance and quality-control guidelines are used to maximize the ability to analyze data locally, regionally, and nationally.

  4. Assembly for collecting samples for purposes of identification or analysis and method of use

    DOEpatents

    Thompson, Cyril V [Knoxville, TN; Smith, Rob R [Knoxville, TN

    2010-02-02

    An assembly and an associated method for collecting a sample of material desired to be characterized with diagnostic equipment includes or utilizes an elongated member having a proximal end with which the assembly is manipulated by a user and a distal end. In addition, a collection tip which is capable of being placed into contact with the material to be characterized is supported upon the distal end. The collection tip includes a body of chemically-inert porous material for binding a sample of material when the tip is placed into contact with the material and thereby holds the sample of material for subsequent introduction to the diagnostic equipment.

  5. Extravehicular Activity Asteroid Exploration and Sample Collection Capability

    NASA Technical Reports Server (NTRS)

    Scoville, Zebulon; Sipila, Stephanie; Bowie, Jonathan

    2014-01-01

    NASA's Asteroid Redirect Crewed Mission (ARCM) is challenged with primary mission objectives of demonstrating deep space Extravehicular Activity (EVA) and tools, and obtaining asteroid samples to return to Earth for further study. Although the Modified Advanced Crew Escape Suit (MACES) is used for the EVAs, it has limited mobility which increases fatigue and decreases the crews' capability to perform EVA tasks. Furthermore, previous Shuttle and International Space Station (ISS) spacewalks have benefited from EVA interfaces which have been designed and manufactured on Earth. Rigid structurally mounted handrails, and tools with customized interfaces and restraints optimize EVA performance. For ARCM, some vehicle interfaces and tools can leverage heritage designs and experience. However, when the crew ventures onto an asteroid capture bag to explore the asteroid and collect rock samples, EVA complexity increases due to the uncertainty of the asteroid properties. The variability of rock size, shape and composition, as well as bunching of the fabric bag will complicate EVA translation, tool restraint and body stabilization. The unknown asteroid hardness and brittleness will complicate tool use. The rock surface will introduce added safety concerns for cut gloves and debris control. Feasible solutions to meet ARCM EVA objectives were identified using experience gained during Apollo, Shuttle, and ISS EVAs, terrestrial mountaineering practices, NASA Extreme Environment Mission Operations (NEEMO) 16 mission, and during Neutral Buoyancy Laboratory testing in the MACES suit. The proposed concept utilizes expandable booms and integrated features of the asteroid capture bag to position and restrain the crew at the asteroid worksite. These methods enable the capability to perform both finesse, and high load tasks necessary to collect samples for scientific characterization of the asteroid. This paper will explore the design trade space and options that were examined for EVA, the

  6. 21 CFR 864.3260 - OTC test sample collection systems for drugs of abuse testing.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... abuse testing. 864.3260 Section 864.3260 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF... Instrumentation and Accessories § 864.3260 OTC test sample collection systems for drugs of abuse testing. (a) Identification. An over-the-counter (OTC) test sample collection system for drugs of abuse testing is a device...

  7. 21 CFR 864.3260 - OTC test sample collection systems for drugs of abuse testing.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... abuse testing. 864.3260 Section 864.3260 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF... Instrumentation and Accessories § 864.3260 OTC test sample collection systems for drugs of abuse testing. (a) Identification. An over-the-counter (OTC) test sample collection system for drugs of abuse testing is a device...

  8. 21 CFR 864.3260 - OTC test sample collection systems for drugs of abuse testing.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... abuse testing. 864.3260 Section 864.3260 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF... Instrumentation and Accessories § 864.3260 OTC test sample collection systems for drugs of abuse testing. (a) Identification. An over-the-counter (OTC) test sample collection system for drugs of abuse testing is a device...

  9. 21 CFR 864.3260 - OTC test sample collection systems for drugs of abuse testing.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... abuse testing. 864.3260 Section 864.3260 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF... Instrumentation and Accessories § 864.3260 OTC test sample collection systems for drugs of abuse testing. (a) Identification. An over-the-counter (OTC) test sample collection system for drugs of abuse testing is a device...

  10. Macroinvertebrate community sample collection methods and data collected from Sand Creek and Medano Creek, Great Sand Dunes National Park and Preserve, Colorado, 2005–07

    USGS Publications Warehouse

    Ford, Morgan A.; Zuellig, Robert E.; Walters, David M.; Bruce, James F.

    2016-08-11

    This report provides a table of site descriptions, sample information, and semiquantitative aquatic macroinvertebrate data from 105 samples collected between 2005 and 2007 from 7 stream sites within the Sand Creek and Medano Creek watersheds in Great Sand Dunes National Park and Preserve, Saguache County, Colorado. Additionally, a short description of sample collection methods and laboratory sample processing procedures is presented. These data were collected in anticipation of assessing the potential effects of fish toxicants on macroinvertebrates.

  11. Field guide for collecting and processing stream-water samples for the National Water-Quality Assessment Program

    USGS Publications Warehouse

    Shelton, Larry R.

    1994-01-01

    The U.S. Geological Survey's National Water-Quality Assessment program includes extensive data- collection efforts to assess the quality of the Nations's streams. These studies require analyses of stream samples for major ions, nutrients, sediments, and organic contaminants. For the information to be comparable among studies in different parts of the Nation, consistent procedures specifically designed to produce uncontaminated samples for trace analysis in the laboratory are critical. This field guide describes the standard procedures for collecting and processing samples for major ions, nutrients, organic contaminants, sediment, and field analyses of conductivity, pH, alkalinity, and dissolved oxygen. Samples are collected and processed using modified and newly designed equipment made of Teflon to avoid contamination, including nonmetallic samplers (D-77 and DH-81) and a Teflon sample splitter. Field solid-phase extraction procedures developed to process samples for organic constituent analyses produce an extracted sample with stabilized compounds for more accurate results. Improvements to standard operational procedures include the use of processing chambers and capsule filtering systems. A modified collecting and processing procedure for organic carbon is designed to avoid contamination from equipment cleaned with methanol. Quality assurance is maintained by strict collecting and processing procedures, replicate sampling, equipment blank samples, and a rigid cleaning procedure using detergent, hydrochloric acid, and methanol.

  12. Comparison of semen parameters in samples collected by masturbation at a clinic and at home.

    PubMed

    Elzanaty, Saad; Malm, Johan

    2008-06-01

    To investigate differences in semen quality between samples collected by masturbation at a clinic and at home. Cross-sectional study. Fertility center. Three hundred seventy-nine men assessed for infertility. None. Semen was analyzed according to World Health Organization guidelines. Seminal markers of epididymal (neutral alpha-glucosidase), prostatic (prostate-specific antigen and zinc), and seminal vesicle (fructose) function were measured. Two patient groups were defined according to sample collection location: at a clinic (n = 273) or at home (n = 106). Compared with clinic-collected semen, home-collected samples had statistically significantly higher values for sperm concentration, total sperm count, rapid progressive motility, and total count of progressive motility. Semen volume, proportion of normal sperm morphology, neutral alpha-glucosidase, prostate-specific antigen, zinc, and fructose did not differ significantly between groups. An abnormal sperm concentration (<20 x 10(6)/mL) was seen in statistically significantly fewer of the samples obtained at home (19/106, 18%) than at the clinic (81/273, 30%), and the same applied to proportions of samples with abnormal (< 25%) rapid progressive motility (68/106 [64%] and 205/273 [75%], respectively). The present results demonstrate superior semen quality in samples collected by masturbation at home compared with at a clinic. This should be taken into consideration in infertility investigations.

  13. Development and validation of a measure of criminal social identity within a sample of Polish recidivistic prisoners.

    PubMed

    Boduszek, Daniel; Adamson, Gary; Shevlin, Mark; Hyland, Philip

    2012-12-01

    Social identity is a well-established theoretical concept within psychological research; however, the role of criminal social identity has received far less research attention. One salient reason for the limited research relating to the concept of criminal social identity is the absence of a specific measure. To develop and test the construct validity of a new measure of criminal social identity (MCSI) and to provide additional evidence relating to Cameron's three-factor conceptualisation of social identity. The eight-item MCSI was used to collect data from recidivists incarcerated in high-security prison (N=312) to assess criminal social identification. These data were subjected to confirmatory factor analysis. Three alternative models of criminal social identity were specified and tested in Mplus 6, and results revealed that the data were best explained by a three-factor model of criminal social identity (cognitive centrality, in-group affect and in-group ties). The current study is important in terms of future research in criminology and psychology because the MCSI provides the first reliable MCSI, which was developed and validated on a relatively large recidivistic prison sample. Copyright © 2012 John Wiley & Sons, Ltd.

  14. The Importance of Meteorite Collections to Sample Return Missions: Past, Present, and Future Considerations

    NASA Technical Reports Server (NTRS)

    Welzenbach, L. C.; McCoy, T. J.; Glavin, D. P.; Dworkin, J. P.; Abell, P. A.

    2012-01-01

    While much of the scientific community s current attention is drawn to sample return missions, it is the existing meteorite and cosmic dust collections that both provide the paradigms to be tested by these missions and the context for interpreting the results. Recent sample returns from the Stardust and Hayabusa missions provided us with new materials and insights about our Solar System history and processes. As an example, Stardust sampled CAIs among the population of cometary grains, requiring extensive and unexpected radial mixing in the early solar nebula. This finding would not have been possible, however, without extensive studies of meteoritic CAIs that established their high-temperature, inner Solar System formation. Samples returned by Stardust also revealed the first evidence of a cometary amino acid, a discovery that would not have been possible with current in situ flight instrument technology. The Hayabusa mission provided the final evidence linking ordinary chondrites and S asteroids, a hypothesis that developed from centuries of collection and laboratory and ground-based telescopic studies. In addition to these scientific findings, studies of existing meteorite collections have defined and refined the analytical techniques essential to studying returned samples. As an example, the fortuitous fall of the Allende CV3 and Murchison CM2 chondrites within months before the return of Apollo samples allowed testing of new state-of-the-art analytical facilities. The results of those studies not only prepared us to better study lunar materials, but unanticipated discoveries changed many of our concepts about the earliest history and processes of the solar nebula. This synergy between existing collections and future space exploration is certainly not limited to sample return missions. Laboratory studies confirmed the existence of meteorites from Mars and raised the provocative possibility of preservation of ancient microbial life. The laboratory studies in

  15. Integration of DNA sample collection into a multi-site birth defects case-control study.

    PubMed

    Rasmussen, Sonja A; Lammer, Edward J; Shaw, Gary M; Finnell, Richard H; McGehee, Robert E; Gallagher, Margaret; Romitti, Paul A; Murray, Jeffrey C

    2002-10-01

    Advances in quantitative analysis and molecular genotyping have provided unprecedented opportunities to add biological sampling and genetic information to epidemiologic studies. The purpose of this article is to describe the incorporation of DNA sample collection into the National Birth Defects Prevention Study (NBDPS), an ongoing case-control study in an eight-state consortium with a primary goal to identify risk factors for birth defects. Babies with birth defects are identified through birth defects surveillance systems in the eight participating centers. Cases are infants with one or more of over 30 major birth defects. Controls are infants without defects from the same geographic area. Epidemiologic information is collected through an hour-long interview with mothers of both cases and controls. We added the collection of buccal cytobrush DNA samples for case-infants, control-infants, and their parents to this study. We describe here the methods by which the samples have been collected and processed, establishment of a centralized resource for DNA banking, and quality control, database management, access, informed consent, and confidentiality issues. Biological sampling and genetic analyses are important components to epidemiologic studies of birth defects aimed at identifying risk factors. The DNA specimens collected in this study can be used for detection of mutations, study of polymorphic variants that confer differential susceptibility to teratogens, and examination of interactions among genetic risk factors. Information on the methods used and issues faced by the NBDPS may be of value to others considering the addition of DNA sampling to epidemiologic studies.

  16. Apparatus and process for collection of gas and vapor samples

    DOEpatents

    Jackson, Dennis G [Augusta, GA; Peterson, Kurt D [Aiken, SC; Riha, Brian D [Augusta, GA

    2008-04-01

    A gas sampling apparatus and process is provided in which a standard crimping tool is modified by an attached collar. The collar permits operation of the crimping tool while also facilitating the introduction of a supply of gas to be introduced into a storage vial. The introduced gas supply is used to purge ambient air from a collection chamber and an interior of the sample vial. Upon completion of the purging operation, the vial is sealed using the crimping tool.

  17. Comparison of water-quality samples collected by siphon samplers and automatic samplers in Wisconsin

    USGS Publications Warehouse

    Graczyk, David J.; Robertson, Dale M.; Rose, William J.; Steur, Jeffrey J.

    2000-01-01

    In small streams, flow and water-quality concentrations often change quickly in response to meteorological events. Hydrologists, field technicians, or locally hired stream ob- servers involved in water-data collection are often unable to reach streams quickly enough to observe or measure these rapid changes. Therefore, in hydrologic studies designed to describe changes in water quality, a combination of manual and automated sampling methods have commonly been used manual methods when flow is relatively stable and automated methods when flow is rapidly changing. Auto- mated sampling, which makes use of equipment programmed to collect samples in response to changes in stage and flow of a stream, has been shown to be an effective method of sampling to describe the rapid changes in water quality (Graczyk and others, 1993). Because of the high cost of automated sampling, however, especially for studies examining a large number of sites, alternative methods have been considered for collecting samples during rapidly changing stream conditions. One such method employs the siphon sampler (fig. 1). also referred to as the "single-stage sampler." Siphon samplers are inexpensive to build (about $25- $50 per sampler), operate, and maintain, so they are cost effective to use at a large number of sites. Their ability to collect samples representing the average quality of water passing though the entire cross section of a stream, however, has not been fully demonstrated for many types of stream sites.

  18. Extending the Collection Duration of Breath Samples for Enteric Methane Emission Estimation Using the SF6 Tracer Technique

    PubMed Central

    Pinares-Patiño, César; Gere, José; Williams, Karen; Gratton, Roberto; Juliarena, Paula; Molano, German; MacLean, Sarah; Sandoval, Edgar; Taylor, Grant; Koolaard, John

    2012-01-01

    Simple Summary Extended sample collection for the SF6 tracer technique is desirable for extensive grazing systems. Breath samples from eight cows were collected while lucerne silage was fed to achieve fixed intakes among the cows. Samples were collected over a 10-day period, using either apparatuses used in New Zealand (NZL) or Argentina (ARG), and either daily, over two consecutive 5-day periods or over a 10-day period (in duplicate). The NZL system had a greater sampling success and more consistent CH4 emission estimates than the ARG system, with no differences in mean emissions among sample collection periods. This study showed that extended sample collection is feasible, but definitive evaluation under grazing situation is required before a decision on recommendation can be made. Abstract The daily sample collection protocol of the sulphur hexafluoride (SF6) tracer technique for the estimation of methane (CH4) emissions from ruminants may not be practical under extensive grazing systems. Here, under controlled conditions, we evaluated extended periods of sampling as an alternative to daily sample collections. Eight rumen-fistulated cows were housed and fed lucerne silage to achieve common daily feed intakes of 6.4 kg dry matter per cow. Following SF6 permeation tube dosing, eight sampling lines were fitted to the breath collection harness, so that a common gas mix was available to each line. Half of the lines collected samples into PVC yokes using a modified capillary system as commonly used in New Zealand (NZL), and half collected samples into stainless steel cylinders using a ball-bearing flow restrictor as used in Argentina (ARG), all within a 10-day time frame, either daily, across two consecutive 5-day periods or across one 10-day period (in duplicate). The NZL system had greater sampling success (97.3 vs. 79.5%) and yielded more consistent CH4 emission estimates than the ARG system. Emission estimates from NZL daily, NZL 5-day and NZL 10-day samplings

  19. Collecting and validating experiential expertise is doable but poses methodological challenges.

    PubMed

    Burda, Marika H F; van den Akker, Marjan; van der Horst, Frans; Lemmens, Paul; Knottnerus, J André

    2016-04-01

    To give an overview of important methodological challenges in collecting, validating, and further processing experiential expertise and how to address these challenges. Based on our own experiences in studying the concept, operationalization, and contents of experiential expertise, we have formulated methodological issues regarding the inventory and application of experiential expertise. The methodological challenges can be categorized in six developmental research stages, comprising the conceptualization of experiential expertise, methods to harvest experiential expertise, the validation of experiential expertise, evaluation of the effectiveness, how to translate experiential expertise into acceptable guidelines, and how to implement these. The description of methodological challenges and ways to handle those are illustrated using diabetes mellitus as an example. Experiential expertise can be defined and operationalized in terms of successful illness-related behaviors and translated into recommendations regarding life domains. Pathways have been identified to bridge the gaps between the world of patients' daily lives and the medical world. Copyright © 2016 Elsevier Inc. All rights reserved.

  20. EDRN Breast and Ovary Cancer CVC, Study 3: Phase 3 Validation of screening decision rules in preclinical UKCTOCS serial samples — EDRN Public Portal

    Cancer.gov

    We will collaborate with investigators from University College London to test a screening decision rule in preclinical serial samples from the U.K. Collaborative Trial of Ovarian Cancer Screening (UKCTOCS) to learn if the panel can do better than CA125 alone. The UKCTOCS is an ideal setting for retrospective validation of an early detection marker panel and decision rule because it offers serial samples collected annually and use of imaging in women with rising CA125. Multi-modal strategies using serum markers HE4, MSLN, MMP7, and CA125 will be compared to strategies relying exclusively on CA125 and transvaginal sonography (TVS).

  1. Evaluation of rayon swab surface sample collection method for Bacillus spores from nonporous surfaces.

    PubMed

    Brown, G S; Betty, R G; Brockmann, J E; Lucero, D A; Souza, C A; Walsh, K S; Boucher, R M; Tezak, M S; Wilson, M C; Rudolph, T; Lindquist, H D A; Martinez, K F

    2007-10-01

    To evaluate US Centers for Disease Control and Prevention recommended swab surface sample collection method for recovery efficiency and limit of detection for powdered Bacillus spores from nonporous surfaces. Stainless steel and painted wallboard surface coupons were seeded with dry aerosolized Bacillus atrophaeus spores and surface concentrations determined. The observed mean rayon swab recovery efficiency from stainless steel was 0.41 with a standard deviation (SD) of +/-0.17 and for painted wallboard was 0.41 with an SD of +/-0.23. Evaluation of a sonication extraction method for the rayon swabs produced a mean extraction efficiency of 0.76 with an SD of +/-0.12. Swab recovery quantitative limits of detection were estimated at 25 colony forming units (CFU) per sample area for both stainless steel and painted wallboard. The swab sample collection method may be appropriate for small area sampling (10 -25 cm2) with a high agent concentration, but has limited value for large surface areas with a low agent concentration. The results of this study provide information necessary for the interpretation of swab environmental sample collection data, that is, positive swab samples are indicative of high surface concentrations and may imply a potential for exposure, whereas negative swab samples do not assure that organisms are absent from the surfaces sampled and may not assure the absence of the potential for exposure. It is critical from a public health perspective that the information obtained is accurate and reproducible. The consequence of an inappropriate public health response founded on information gathered using an ineffective or unreliable sample collection method has the potential for undesired social and economic impact.

  2. Sources of variability in collection and preparation of paint and lead-coating samples.

    PubMed

    Harper, S L; Gutknecht, W F

    2001-06-01

    Chronic exposure of children to lead (Pb) can result in permanent physiological impairment. Since surfaces coated with lead-containing paints and varnishes are potential sources of exposure, it is extremely important that reliable methods for sampling and analysis be available. The sources of variability in the collection and preparation of samples were investigated to improve the performance and comparability of methods and to ensure that data generated will be adequate for its intended use. Paint samples of varying sizes (areas and masses) were collected at different locations across a variety of surfaces including metal, plaster, concrete, and wood. A variety of grinding techniques were compared. Manual mortar and pestle grinding for at least 1.5 min and mechanized grinding techniques were found to generate similar homogenous particle size distributions required for aliquots as small as 0.10 g. When 342 samples were evaluated for sample weight loss during mortar and pestle grinding, 4% had 20% or greater loss with a high of 41%. Homogenization and sub-sampling steps were found to be the principal sources of variability related to the size of the sample collected. Analysis of samples from different locations on apparently identical surfaces were found to vary by more than a factor of two both in Pb concentration (mg cm-2 or %) and areal coating density (g cm-2). Analyses of substrates were performed to determine the Pb remaining after coating removal. Levels as high as 1% Pb were found in some substrate samples, corresponding to more than 35 mg cm-2 Pb. In conclusion, these sources of variability must be considered in development and/or application of any sampling and analysis methodologies.

  3. The Validity of the Psychopathic Personality Inventory-Revised in a Community Sample

    ERIC Educational Resources Information Center

    Uzieblo, Katarzyna; Verschuere, Bruno; Van den Bussche, Eva; Crombez, Geert

    2010-01-01

    Research on the Psychopathic Personality Inventory-Revised (PPI-R) has revealed two factors: Fearless Dominance, and Self-Centered Impulsivity. This study examined the validity of these PPI-R factors in a community sample (N = 675). First, confirmatory factor analyses did not support the two-factor structure. Second, the PPI-R factors showed good…

  4. A design of experiments approach to validation sampling for logistic regression modeling with error-prone medical records.

    PubMed

    Ouyang, Liwen; Apley, Daniel W; Mehrotra, Sanjay

    2016-04-01

    Electronic medical record (EMR) databases offer significant potential for developing clinical hypotheses and identifying disease risk associations by fitting statistical models that capture the relationship between a binary response variable and a set of predictor variables that represent clinical, phenotypical, and demographic data for the patient. However, EMR response data may be error prone for a variety of reasons. Performing a manual chart review to validate data accuracy is time consuming, which limits the number of chart reviews in a large database. The authors' objective is to develop a new design-of-experiments-based systematic chart validation and review (DSCVR) approach that is more powerful than the random validation sampling used in existing approaches. The DSCVR approach judiciously and efficiently selects the cases to validate (i.e., validate whether the response values are correct for those cases) for maximum information content, based only on their predictor variable values. The final predictive model will be fit using only the validation sample, ignoring the remainder of the unvalidated and unreliable error-prone data. A Fisher information based D-optimality criterion is used, and an algorithm for optimizing it is developed. The authors' method is tested in a simulation comparison that is based on a sudden cardiac arrest case study with 23 041 patients' records. This DSCVR approach, using the Fisher information based D-optimality criterion, results in a fitted model with much better predictive performance, as measured by the receiver operating characteristic curve and the accuracy in predicting whether a patient will experience the event, than a model fitted using a random validation sample. The simulation comparisons demonstrate that this DSCVR approach can produce predictive models that are significantly better than those produced from random validation sampling, especially when the event rate is low. © The Author 2015. Published by Oxford

  5. Sampling and sample processing in pesticide residue analysis.

    PubMed

    Lehotay, Steven J; Cook, Jo Marie

    2015-05-13

    Proper sampling and sample processing in pesticide residue analysis of food and soil have always been essential to obtain accurate results, but the subject is becoming a greater concern as approximately 100 mg test portions are being analyzed with automated high-throughput analytical methods by agrochemical industry and contract laboratories. As global food trade and the importance of monitoring increase, the food industry and regulatory laboratories are also considering miniaturized high-throughput methods. In conjunction with a summary of the symposium "Residues in Food and Feed - Going from Macro to Micro: The Future of Sample Processing in Residue Analytical Methods" held at the 13th IUPAC International Congress of Pesticide Chemistry, this is an opportune time to review sampling theory and sample processing for pesticide residue analysis. If collected samples and test portions do not adequately represent the actual lot from which they came and provide meaningful results, then all costs, time, and efforts involved in implementing programs using sophisticated analytical instruments and techniques are wasted and can actually yield misleading results. This paper is designed to briefly review the often-neglected but crucial topic of sample collection and processing and put the issue into perspective for the future of pesticide residue analysis. It also emphasizes that analysts should demonstrate the validity of their sample processing approaches for the analytes/matrices of interest and encourages further studies on sampling and sample mass reduction to produce a test portion.

  6. Preliminary assessment of an economical fugitive road dust sampler for the collection of bulk samples for geochemical analysis.

    PubMed

    Witt, Emitt C; Wronkiewicz, David J; Shi, Honglan

    2013-01-01

    Fugitive road dust collection for chemical analysis and interpretation has been limited by the quantity and representativeness of samples. Traditional methods of fugitive dust collection generally focus on point-collections that limit data interpretation to a small area or require the investigator to make gross assumptions about the origin of the sample collected. These collection methods often produce a limited quantity of sample that may hinder efforts to characterize the samples by multiple geochemical techniques, preserve a reference archive, and provide a spatially integrated characterization of the road dust health hazard. To achieve a "better sampling" for fugitive road dust studies, a cyclonic fugitive dust (CFD) sampler was constructed and tested. Through repeated and identical sample collection routes at two collection heights (50.8 and 88.9 cm above the road surface), the products of the CFD sampler were characterized using particle size and chemical analysis. The average particle size collected by the cyclone was 17.9 μm, whereas particles collected by a secondary filter were 0.625 μm. No significant difference was observed between the two sample heights tested and duplicates collected at the same height; however, greater sample quantity was achieved at 50.8 cm above the road surface than at 88.9 cm. The cyclone effectively removed 94% of the particles >1 μm, which substantially reduced the loading on the secondary filter used to collect the finer particles; therefore, suction is maintained for longer periods of time, allowing for an average sample collection rate of about 2 g mi. Copyright © by the American Society of Agronomy, Crop Science Society of America, and Soil Science Society of America, Inc.

  7. Curating NASA's future extraterrestrial sample collections: How do we achieve maximum proficiency?

    NASA Astrophysics Data System (ADS)

    McCubbin, Francis; Evans, Cynthia; Allton, Judith; Fries, Marc; Righter, Kevin; Zolensky, Michael; Zeigler, Ryan

    2016-07-01

    Introduction: The Astromaterials Acquisition and Curation Office (henceforth referred to herein as NASA Curation Office) at NASA Johnson Space Center (JSC) is responsible for curating all of NASA's extraterrestrial samples. Under the governing document, NASA Policy Directive (NPD) 7100.10E "Curation of Extraterrestrial Materials", JSC is charged with "The curation of all extraterrestrial material under NASA control, including future NASA missions." The Directive goes on to define Curation as including "…documentation, preservation, preparation, and distribution of samples for research, education, and public outreach." Here we describe some of the ongoing efforts to ensure that the future activities of the NASA Curation Office are working to-wards a state of maximum proficiency. Founding Principle: Curatorial activities began at JSC (Manned Spacecraft Center before 1973) as soon as design and construction planning for the Lunar Receiving Laboratory (LRL) began in 1964 [1], not with the return of the Apollo samples in 1969, nor with the completion of the LRL in 1967. This practice has since proven that curation begins as soon as a sample return mission is conceived, and this founding principle continues to return dividends today [e.g., 2]. The Next Decade: Part of the curation process is planning for the future, and we refer to these planning efforts as "advanced curation" [3]. Advanced Curation is tasked with developing procedures, technology, and data sets necessary for curating new types of collections as envisioned by NASA exploration goals. We are (and have been) planning for future curation, including cold curation, extended curation of ices and volatiles, curation of samples with special chemical considerations such as perchlorate-rich samples, curation of organically- and biologically-sensitive samples, and the use of minimally invasive analytical techniques (e.g., micro-CT, [4]) to characterize samples. These efforts will be useful for Mars Sample Return

  8. Planning for the Collection and Analysis of Samples of Martian Granular Materials Potentially to be Returned by Mars Sample Return

    NASA Astrophysics Data System (ADS)

    Carrier, B. L.; Beaty, D. W.

    2017-12-01

    NASA's Mars 2020 rover is scheduled to land on Mars in 2021 and will be equipped with a sampling system capable of collecting rock cores, as well as a specialized drill bit for collecting unconsolidated granular material. A key mission objective is to collect a set of samples that have enough scientific merit to justify returning to Earth. In the case of granular materials, we would like to catalyze community discussion on what we would do with these samples if they arrived in our laboratories, as input to decision-making related to sampling the regolith. Numerous scientific objectives have been identified which could be achieved or significantly advanced via the analysis of martian rocks, "regolith," and gas samples. The term "regolith" has more than one definition, including one that is general and one that is much more specific. For the purpose of this analysis we use the term "granular materials" to encompass the most general meaning and restrict "regolith" to a subset of that. Our working taxonomy includes the following: 1) globally sourced airfall dust (dust); 2) saltation-sized particles (sand); 3) locally sourced decomposed rock (regolith); 4) crater ejecta (ejecta); and, 5) other. Analysis of martian granular materials could serve to advance our understanding areas including habitability and astrobiology, surface-atmosphere interactions, chemistry, mineralogy, geology and environmental processes. Results of these analyses would also provide input into planning for future human exploration of Mars, elucidating possible health and mechanical hazards caused by the martian surface material, as well as providing valuable information regarding available resources for ISRU and civil engineering purposes. Results would also be relevant to matters of planetary protection and ground-truthing orbital observations. We will present a preliminary analysis of the following, in order to generate community discussion and feedback on all issues relating to: What are the

  9. Validation and Assessment of Three Methods to Estimate 24-h Urinary Sodium Excretion from Spot Urine Samples in Chinese Adults

    PubMed Central

    Peng, Yaguang; Li, Wei; Wang, Yang; Chen, Hui; Bo, Jian; Wang, Xingyu; Liu, Lisheng

    2016-01-01

    24-h urinary sodium excretion is the gold standard for evaluating dietary sodium intake, but it is often not feasible in large epidemiological studies due to high participant burden and cost. Three methods—Kawasaki, INTERSALT, and Tanaka—have been proposed to estimate 24-h urinary sodium excretion from a spot urine sample, but these methods have not been validated in the general Chinese population. This aim of this study was to assess the validity of three methods for estimating 24-h urinary sodium excretion using spot urine samples against measured 24-h urinary sodium excretion in a Chinese sample population. Data are from a substudy of the Prospective Urban Rural Epidemiology (PURE) study that enrolled 120 participants aged 35 to 70 years and collected their morning fasting urine and 24-h urine specimens. Bias calculations (estimated values minus measured values) and Bland-Altman plots were used to assess the validity of the three estimation methods. 116 participants were included in the final analysis. Mean bias for the Kawasaki method was -740 mg/day (95% CI: -1219, 262 mg/day), and was the lowest among the three methods. Mean bias for the Tanaka method was -2305 mg/day (95% CI: -2735, 1875 mg/day). Mean bias for the INTERSALT method was -2797 mg/day (95% CI: -3245, 2349 mg/day), and was the highest of the three methods. Bland-Altman plots indicated that all three methods underestimated 24-h urinary sodium excretion. The Kawasaki, INTERSALT and Tanaka methods for estimation of 24-h urinary sodium excretion using spot urines all underestimated true 24-h urinary sodium excretion in this sample of Chinese adults. Among the three methods, the Kawasaki method was least biased, but was still relatively inaccurate. A more accurate method is needed to estimate the 24-h urinary sodium excretion from spot urine for assessment of dietary sodium intake in China. PMID:26895296

  10. Psychometric Validation of the Academic Motivation Scale in a Dental Student Sample.

    PubMed

    Orsini, Cesar; Binnie, Vivian; Evans, Phillip; Ledezma, Priscilla; Fuentes, Fernando; Villegas, Maria J

    2015-08-01

    The Academic Motivation Scale is one of the most frequently used instruments to assess academic motivation. It relies on the self-determination theory of human motivation. However, motivation has been understudied in dental education. Therefore, to address the lack of valid instruments to assess academic motivation in dental education and contribute to future research in the field, the aim of this study was to analyze the psychometric properties of this instrument in a sample of dental students. Participants were 989 Chilean undergraduate dental students (86% response rate) who completed a survey containing a Chilean face-valid version of the Spanish Academic Motivation Scale and three other motivation-related instruments to assess the survey's construct and criterion validity. Later, 76 of the students (out of 100 invited) took the survey again to assess its test-retest stability. The instrument's construct validity was supported by the superior goodness of fit of the seven-subscale Academic Motivation Scale over competing models through confirmatory factor analysis and by the expected correlations among its subscales. The concurrent criterion validity was supported by the confirmation of correlations between its subscales and external criteria. Adequate internal consistency and test-retest correlations were also found. The evidence from this study suggests that the Academic Motivation Scale is a preliminarily valid and reliable instrument to assess motivation in the predoctoral dental context. Future research in this area is needed to confirm or refute these results.

  11. The Pemberton Happiness Index: Validation of the Universal Portuguese version in a large Brazilian sample.

    PubMed

    Paiva, Bianca Sakamoto Ribeiro; de Camargos, Mayara Goulart; Demarzo, Marcelo Marcos Piva; Hervás, Gonzalo; Vázquez, Carmelo; Paiva, Carlos Eduardo

    2016-09-01

    The Pemberton Happiness Index (PHI) is a recently developed integrative measure of well-being that includes components of hedonic, eudaimonic, social, and experienced well-being. The PHI has been validated in several languages, but not in Portuguese. Our aim was to cross-culturally adapt the Universal Portuguese version of the PHI and to assess its psychometric properties in a sample of the Brazilian population using online surveys.An expert committee evaluated 2 versions of the PHI previously translated into Portuguese by the original authors using a standardized form for assessment of semantic/idiomatic, cultural, and conceptual equivalence. A pretesting was conducted employing cognitive debriefing methods. In sequence, the expert committee evaluated all the documents and reached a final Universal Portuguese PHI version. For the evaluation of the psychometric properties, the data were collected using online surveys in a cross-sectional study. The study population included healthcare professionals and users of the social network site Facebook from several Brazilian geographic areas. In addition to the PHI, participants completed the Satisfaction with Life Scale (SWLS), Diener and Emmons' Positive and Negative Experience Scale (PNES), Psychological Well-being Scale (PWS), and the Subjective Happiness Scale (SHS). Internal consistency, convergent validity, known-group validity, and test-retest reliability were evaluated. Satisfaction with the previous day was correlated with the 10 items assessing experienced well-being using the Cramer V test. Additionally, a cut-off value of PHI to identify a "happy individual" was defined using receiver-operating characteristic (ROC) curve methodology.Data from 1035 Brazilian participants were analyzed (health professionals = 180; Facebook users = 855). Regarding reliability results, the internal consistency (Cronbach alpha = 0.890 and 0.914) and test-retest (intraclass correlation coefficient = 0.814) were both considered

  12. Validation of the Sexual Orientation Microaggression Inventory in Two Diverse Samples of LGBTQ Youth.

    PubMed

    Swann, Gregory; Minshew, Reese; Newcomb, Michael E; Mustanski, Brian

    2016-08-01

    Critical race theory asserts that microaggressions, or low-level, covert acts of aggression, are commonplace in the lives of people of color. These theorists also assert a taxonomy of microaggressions, which includes "microassaults," "microinsults," and "microinvalidations". The theory of microaggressions has been adopted by researchers of LGBTQ communities. This study investigated the three-factor taxonomy as it relates to a diverse sample of LGBTQ youth using the newly developed Sexual Orientation Microaggression Inventory (SOMI). Exploratory factor analysis was used to determine the number of factors that exist in SOMI in a sample of 206 LGBTQ-identifying youth. Follow up confirmatory factor analyses were conducted in order to compare single-factor, unrestricted four-factor, second-order, and bi-factor models in a separate sample of 363 young men who have sex with men. The best fitting model was used to predict victimization, depressive symptoms, and depression diagnosis in order to test validity. The best fitting model was a bi-factor model utilizing 19 of the original 26 items with a general factor and four specific factors representing anti-gay attitudes ("microinsults"), denial of homosexuality, heterosexism ("microinvalidations"), and societal disapproval ("microassaults"). Reliability analyses found that the majority of reliable variance was accounted for by the general factor. The general factor was a significant predictor of victimization and depressive symptoms, as well as unrelated to social desirability, suggesting convergent, criterion-related, and discriminant validity. SOMI emerged as a scale with evidence of validity for assessing exposure to microaggressions in a diverse sample of LGBTQ youth.

  13. Collecting Quality Infrared Spectra from Microscopic Samples of Suspicious Powders in a Sealed Cell.

    PubMed

    Kammrath, Brooke W; Leary, Pauline E; Reffner, John A

    2017-03-01

    The infrared (IR) microspectroscopical analysis of samples within a sealed-cell containing barium fluoride is a critical need when identifying toxic agents or suspicious powders of unidentified composition. The dispersive nature of barium fluoride is well understood and experimental conditions can be easily adjusted during reflection-absorption measurements to account for differences in focus between the visible and IR regions of the spectrum. In most instances, the ability to collect a viable spectrum is possible when using the sealed cell regardless of whether visible or IR focus is optimized. However, when IR focus is optimized, it is possible to collect useful data from even smaller samples. This is important when a minimal sample is available for analysis or the desire to minimize risk of sample exposure is important. While the use of barium fluoride introduces dispersion effects that are unavoidable, it is possible to adjust instrument settings when collecting IR spectra in the reflection-absorption mode to compensate for dispersion and minimize impact on the quality of the sample spectrum.

  14. Astronaut John Young collecting samples at North Ray crater during EVA

    NASA Image and Video Library

    1972-04-23

    AS16-117-18825 (23 April 1972) --- Astronaut John W. Young, Apollo 16 commander, with a sample bag in his left hand, moves toward the bottom part of the gnomon (center) while collecting samples at the North Ray Crater geological site. Note how soiled Young's Extravehicular Mobility Unit (EMU) is during this the third and final Apollo 16 extravehicular activity (EVA). The Lunar Roving Vehicle (LRV) is parked at upper left.

  15. Acceptability of self-collection sampling for HPV-DNA testing in low-resource settings: a mixed methods approach.

    PubMed

    Bansil, Pooja; Wittet, Scott; Lim, Jeanette L; Winkler, Jennifer L; Paul, Proma; Jeronimo, Jose

    2014-06-12

    Vaginal self-sampling with HPV-DNA tests is a promising primary screening method for cervical cancer. However, women's experiences, concerns and the acceptability of such tests in low-resource settings remain unknown. In India, Nicaragua, and Uganda, a mixed-method design was used to collect data from surveys (N = 3,863), qualitative interviews (N = 72; 20 providers and 52 women) and focus groups (N = 30 women) on women's and providers' experiences with self-sampling, women's opinions of sampling at home, and their future needs. Among surveyed women, 90% provided a self- collected sample. Of these, 75% reported it was easy, although 52% were initially concerned about hurting themselves and 24% were worried about not getting a good sample. Most surveyed women preferred self-sampling (78%). However it was not clear if they responded to the privacy of self-sampling or the convenience of avoiding a pelvic examination, or both. In follow-up interviews, most women reported that they didn't mind self-sampling, but many preferred to have a provider collect the vaginal sample. Most women also preferred clinic-based screening (as opposed to home-based self-sampling), because the sample could be collected by a provider, women could receive treatment if needed, and the clinic was sanitary and provided privacy. Self-sampling acceptability was higher when providers prepared women through education, allowed women to examine the collection brush, and were present during the self-collection process. Among survey respondents, aids that would facilitate self-sampling in the future were: staff help (53%), additional images in the illustrated instructions (31%), and a chance to practice beforehand with a doll/model (26%). Self-and vaginal-sampling are widely acceptable among women in low-resource settings. Providers have a unique opportunity to educate and prepare women for self-sampling and be flexible in accommodating women's preference for self-sampling.

  16. Collection of Pyrethroids in Water and Sediment Matrices: Development and Validation of a Standard Operating Procedure

    USGS Publications Warehouse

    Hladik, Michelle; Orlando, James L.; Kuivila, Kathryn

    2009-01-01

    Loss of pyrethroid insecticides onto surfaces during sample collection can confound the interpretation of analytical and toxicity test results. Sample collection devices, container materials, and water matrix composition have a significant influence on the association of pyrethroids to container walls, which can be as high as 50 percent. Any sample collection method involving transfer through multiple containers or pieces of equipment increases the potential for pyrethroid loss. This loose 'surface-association' with container walls can be reversed through agitation. When sampling water matrices with pumps or autosamplers, no pyrethroids were lost as long as the water was moving continuously through the system. When collecting water matrices in containers, the material with the least amount of pyrethroid sorption is as follows: glass less than (<) plastic less than (<) Teflon. Additionally, pyrethroids were easier to re-suspend from the glass container walls. Since the amount of surface-association is proportional to the ratio of volume-to-contact-area of the sample, taking larger-volume field samples (greater than 3 liters) reduced pyrethroid losses to less than 10 percent. The amount of surface-association cannot be predicted easily because of the dependence on water matrix composition; samples with higher dissolved organic carbon or suspended-sediment concentrations were observed to have lower percent loss. Sediment samples were not affected by glass-container sorption (the only containers tested). Standardized sample-collection protocols are critical to yield accurate pyrethroid concentrations for assessment of potential effects, and have been summarized in an accompanying standard operating procedure.

  17. A New Symptom Model for Autism Cross-Validated in an Independent Sample

    ERIC Educational Resources Information Center

    Boomsma, A.; Van Lang, N. D. J.; De Jonge, M. V.; De Bildt, A. A.; Van Engeland, H.; Minderaa, R. B.

    2008-01-01

    Background: Results from several studies indicated that a symptom model other than the DSM triad might better describe symptom domains of autism. The present study focused on a) investigating the stability of a new symptom model for autism by cross-validating it in an independent sample and b) examining the invariance of the model regarding three…

  18. Validity of the Aberrant Behavior Checklist in a Clinical Sample of Toddlers

    ERIC Educational Resources Information Center

    Karabekiroglu, Koray; Aman, Michael G.

    2009-01-01

    We investigated the congruent and criterion validity of the Aberrant Behavior Checklist (ABC) in a clinical sample of toddlers seen over 1 year in Turkey. All consecutive patients (N = 93), 14-43 months old (mean, 30.6 mos.), in a child psychiatry outpatient clinic were included. The ABC, Autism Behavior Checklist (AuBC), and Child Behavior…

  19. Conceptual study and key technology development for Mars Aeroflyby sample collection

    NASA Astrophysics Data System (ADS)

    Fujita, K.; Ozawa, T.; Okudaira, K.; Mikouchi, T.; Suzuki, T.; Takayanagi, H.; Tsuda, Y.; Ogawa, N.; Tachibana, S.; Satoh, T.

    2014-01-01

    Conceptual study of Mars Aeroflyby Sample Collection (MASC) is conducted as a part of the next Mars exploration mission currently entertained in Japan Aerospace Exploration Agency. In the mission scenario, an atmospheric entry vehicle is flown into the Martian atmosphere, collects the Martian dust particles as well as atmospheric gases during the guided hypersonic flight, exits the Martian atmosphere, and is inserted into a parking orbit from which a return system departs for the earth to deliver the dust and gas samples. In order to accomplish a controlled flight and a successful orbit insertion, aeroassist orbit transfer technologies are introduced into the guidance and control system. System analysis is conducted to assess the feasibility and to make a conceptual design, finding that the MASC system is feasible at the minimum system mass of 600 kg approximately. The aerogel, which is one of the candidates for the dust sample collector, is assessed by arcjet heating tests to examine its behavior when exposed to high-temperature gases, as well as by particle impingement tests to evaluate its dust capturing capability.

  20. Validation and Uncertainty Estimates for MODIS Collection 6 "Deep Blue" Aerosol Data

    NASA Technical Reports Server (NTRS)

    Sayer, A. M.; Hsu, N. C.; Bettenhausen, C.; Jeong, M.-J.

    2013-01-01

    The "Deep Blue" aerosol optical depth (AOD) retrieval algorithm was introduced in Collection 5 of the Moderate Resolution Imaging Spectroradiometer (MODIS) product suite, and complemented the existing "Dark Target" land and ocean algorithms by retrieving AOD over bright arid land surfaces, such as deserts. The forthcoming Collection 6 of MODIS products will include a "second generation" Deep Blue algorithm, expanding coverage to all cloud-free and snow-free land surfaces. The Deep Blue dataset will also provide an estimate of the absolute uncertainty on AOD at 550 nm for each retrieval. This study describes the validation of Deep Blue Collection 6 AOD at 550 nm (Tau(sub M)) from MODIS Aqua against Aerosol Robotic Network (AERONET) data from 60 sites to quantify these uncertainties. The highest quality (denoted quality assurance flag value 3) data are shown to have an absolute uncertainty of approximately (0.086+0.56Tau(sub M))/AMF, where AMF is the geometric air mass factor. For a typical AMF of 2.8, this is approximately 0.03+0.20Tau(sub M), comparable in quality to other satellite AOD datasets. Regional variability of retrieval performance and comparisons against Collection 5 results are also discussed.

  1. Bayesian assurance and sample size determination in the process validation life-cycle.

    PubMed

    Faya, Paul; Seaman, John W; Stamey, James D

    2017-01-01

    Validation of pharmaceutical manufacturing processes is a regulatory requirement and plays a key role in the assurance of drug quality, safety, and efficacy. The FDA guidance on process validation recommends a life-cycle approach which involves process design, qualification, and verification. The European Medicines Agency makes similar recommendations. The main purpose of process validation is to establish scientific evidence that a process is capable of consistently delivering a quality product. A major challenge faced by manufacturers is the determination of the number of batches to be used for the qualification stage. In this article, we present a Bayesian assurance and sample size determination approach where prior process knowledge and data are used to determine the number of batches. An example is presented in which potency uniformity data is evaluated using a process capability metric. By using the posterior predictive distribution, we simulate qualification data and make a decision on the number of batches required for a desired level of assurance.

  2. Control of the positional relationship between a sample collection instrument and a surface to be analyzed during a sampling procedure with image analysis

    DOEpatents

    Van Berkel, Gary J.; Kertesz, Vilmos

    2011-08-09

    A system and method utilizes an image analysis approach for controlling the collection instrument-to-surface distance in a sampling system for use, for example, with mass spectrometric detection. Such an approach involves the capturing of an image of the collection instrument or the shadow thereof cast across the surface and the utilization of line average brightness (LAB) techniques to determine the actual distance between the collection instrument and the surface. The actual distance is subsequently compared to a target distance for re-optimization, as necessary, of the collection instrument-to-surface during an automated surface sampling operation.

  3. Water column and bed-sediment core samples collected from Brownlee Reservoir near Oxbow, Oregon, 2012

    USGS Publications Warehouse

    Fosness, Ryan L.; Naymik, Jesse; Hopkins, Candice B.; DeWild, John F.

    2013-01-01

    The U.S. Geological Survey, in cooperation with Idaho Power Company, collected water-column and bed-sediment core samples from eight sites in Brownlee Reservoir near Oxbow, Oregon, during May 5–7, 2012. Water-column and bed-sediment core samples were collected at each of the eight sites and analyzed for total mercury and methylmercury. Additional bed-sediment core samples, collected from three of the eight sites, were analyzed for pesticides and other organic compounds, trace metals, and physical characteristics, such as particle size. Total mercury and methylmercury were detected in each of the water column and bed-sediment core samples. Only 17 of the 417 unique pesticide and organic compounds were detected in bed-sediment core samples. Concentrations of most organic wastewater compounds detected in bed sediment were less than the reporting level. Trace metals detected were greater than the reporting level in all the bed-sediment core samples submitted for analysis. The particle size distribution of bed-sediment core samples was predominantly clay mixed with silt.

  4. Validity of the Malaise Inventory in general population samples.

    PubMed

    Rodgers, B; Pickles, A; Power, C; Collishaw, S; Maughan, B

    1999-06-01

    The Malaise Inventory is a commonly used self-completion scale for assessing psychiatric morbidity. There is some evidence that it may represent two separate psychological and somatic subscales rather than a single underlying factor of distress. This paper provides further information on the factor structure of the Inventory and on the reliability and validity of the total scale and two sub-scales. Two general population samples completed the full Inventory: over 11,000 subjects from the National Child Development Study at ages 23 and 33, and 544 mothers of adolescents included in the Isle of Wight epidemiological surveys. The internal consistency of the full 24-item scale and the 15-item psychological subscale were found to be acceptable, but the eight-item somatic sub-scale was less reliable. Factor analysis of all 24 items identified a first main general factor and a second more purely psychological factor. Receiver operating characteristic (ROC) analysis indicated that the validity of the scale held for men and women separately and for different socio-economic groups, by reference to external criteria covering current or recent psychiatric morbidity and service use, and that the psychological sub-scale had no greater validity than the full scale. This study did not support the separate scoring of a somatic sub-scale of the Malaise Inventory. Use of the 15-item psychological sub-scale can be justified on the grounds of reduced time and cost for completion, with little loss of reliability or validity, but this approach would not significantly enhance the properties of the Inventory by comparison with the full 24-item scale. Inclusion of somatic items may be more problematic when the full scale is used to compare particular sub-populations with different propensities for physical morbidity, such as different age groups, and in these circumstances it would be a sensible precaution to utilise the 15-item psychological sub-scale.

  5. Evaluation of a new simple collection device for sampling of microparticles in exhaled breath.

    PubMed

    Seferaj, Sabina; Ullah, Shahid; Tinglev, Åsa; Carlsson, Sten; Winberg, Jesper; Stambeck, Peter; Beck, Olof

    2018-03-12

    The microparticle fraction of exhaled breath is of interest for developing clinical biomarkers. Exhaled particles may contain non-volatile components from all parts of the airway system, formed during normal breathing. This study aimed to evaluate a new, simple sampling device, based on impaction, for collecting microparticles from exhaled breath. Performance of the new device was compared with that of the existing SensAbues membrane filter device. The analytical work used liquid chromatography-tandem mass spectrometry methods. The new device collected three subsamples and these were separately analysed from eight individuals. No difference was observed between the centre position (0.91 ng/sample) and the side positions (1.01 ng/sample) using major phosphatidylcholine (PC) 16:0/16:0 as the analyte. Exhaled breath was collected from eight patients on methadone maintenance treatment. The intra-individual variability in measured methadone concentration between the three collectors was 8.7%. In another experiment using patients on methadone maintenance treatment, the sampling efficiency was compared with an established filter device. Compared to the existing device, the efficiency of the new device was 121% greater for methadone and 1450% greater for DPPC. The data from lipid analysis also indicated that a larger fraction of the collected material was from the distal parts. Finally, a study using an optical particle counter indicated that the device preferentially collects the larger particle fraction. In conclusion, this study demonstrates the usefulness of the new device for collecting non-volatile components from exhaled breath. The performance of the device was superior to the filter device in several aspects.

  6. The Development and Validation of an Instrument That Measures Student Perceptions of Teacher Credibility.

    ERIC Educational Resources Information Center

    Lapan, Stephen D.

    The purpose of this study was to develop and validate an instrument to collect student judgments regarding their teacher's credibility. Items were developed and evidence of content validity generated. A pilot sample and a final sample of high school students were administered the Source Credibility Measure (SCM) so that actual response data could…

  7. [Establishment and Management of Multicentral Collection Bio-sample Banks of Malignant Tumors from Digestive System].

    PubMed

    Shen, Si; Shen, Junwei; Zhu, Liang; Wu, Chaoqun; Li, Dongliang; Yu, Hongyu; Qiu, Yuanyuan; Zhou, Yi

    2015-11-01

    To establish and manage of multicentral collection bio-sample banks of malignant tumors from digestive system, the paper designed a multicentral management system, established the standard operation procedures (SOPs) and leaded ten hospitals nationwide to collect tumor samples. The biobank has been established for half a year, and has collected 695 samples from patients with digestive system malignant tumor. The clinical data is full and complete, labeled in a unified way and classified to be managed. The clinical and molecular biology researches were based on the biobank, and obtained achievements. The biobank provides a research platform for malignant tumor of digestive system from different regions and of different types.

  8. Sample collection and preparation of biofluids and extracts for gas chromatography-mass spectrometry.

    PubMed

    Emwas, Abdul-Hamid M; Al-Talla, Zeyad A; Kharbatia, Najeh M

    2015-01-01

    To maximize the utility of gas chromatography-mass spectrometry (GC-MS) in metabonomics research, all stages of the experimental design should be standardized, including sample collection, storage, preparation, and sample separation. Moreover, the prerequisite for any GC-MS analysis is that a compound must be volatile and thermally stable if it is to be analyzed using this technique. Since many metabolites are nonvolatile and polar in nature, they are not readily amenable to analysis by GC-MS and require initial chemical derivatization of the polar functional groups in order to reduce the polarity and to increase the thermal stability and volatility of the analytes. In this chapter, an overview is presented of the optimum approach to sample collection, storage, and preparation for gas chromatography-mass spectrometry-based metabonomics with particular focus on urine samples as example of biofluids.

  9. Improving the Quality of Adult Mortality Data Collected in Demographic Surveys: Validation Study of a New Siblings' Survival Questionnaire in Niakhar, Senegal

    PubMed Central

    Helleringer, Stéphane; Pison, Gilles; Masquelier, Bruno; Kanté, Almamy Malick; Douillot, Laetitia; Duthé, Géraldine; Sokhna, Cheikh; Delaunay, Valérie

    2014-01-01

    Background In countries with limited vital registration, adult mortality is frequently estimated using siblings' survival histories (SSHs) collected during Demographic and Health Surveys (DHS). These data are affected by reporting errors. We developed a new SSH questionnaire, the siblings' survival calendar (SSC). It incorporates supplementary interviewing techniques to limit omissions of siblings and uses an event history calendar to improve reports of dates and ages. We hypothesized that the SSC would improve the quality of adult mortality data. Methods and Findings We conducted a retrospective validation study among the population of the Niakhar Health and Demographic Surveillance System in Senegal. We randomly assigned men and women aged 15–59 y to an interview with either the DHS questionnaire or the SSC. We compared SSHs collected in each group to prospective data on adult mortality collected in Niakhar. The SSC reduced respondents' tendency to round reports of dates and ages to the nearest multiple of five or ten (“heaping”). The SSC also had higher sensitivity in recording adult female deaths: among respondents whose sister(s) had died at an adult age in the past 15 y, 89.6% reported an adult female death during SSC interviews versus 75.6% in DHS interviews (p = 0.027). The specificity of the SSC was similar to that of the DHS questionnaire, i.e., it did not increase the number of false reports of deaths. However, the SSC did not improve the reporting of adult deaths among the brothers of respondents. Study limitations include sample selectivity, limited external validity, and multiple testing. Conclusions The SSC has the potential to collect more accurate SSHs than the questionnaire used in DHS. Further research is needed to assess the effects of the SSC on estimates of adult mortality rates. Additional validation studies should be conducted in different social and epidemiological settings. Trial Registration Controlled-Trials.com ISRCTN06849961

  10. Perceived Organizational Justice in Care Services: creation and multi-sample validation of a measure.

    PubMed

    Pérez-Arechaederra, Diana; Briones, Elena; Lind, Allan; García-Ortiz, Luis

    2014-02-01

    Organizational justice (OJ) perceptions predict attitudes and behaviors of customers and employees across a broad range of services. Although OJ has proven predictive power and relevance, it has rarely been studied in health care settings. This stems partially from the lack of a reliable and valid measure of patients' OJ in health care encounters. The objective here was to create and validate a measure of patients' OJ. With that purpose, a survey study with two sampling contexts - the U.S. and Spain - was carried out in order to provide a cross-national validation of the scale in two versions: English (Perceived Organizational Justice in Care Services, PJustCS) and Spanish (Percepción de Justicia Organizacional en el Ámbito Sanitario, PJustAS). Exploratory Factor Analysis (EFA) and Confirmatory Factor Analysis (CFA) were used to select the appropriate items in the final version of the instrument. Reliability and validity of the measure were tested. A total of 406 patients in the U.S. and 473 patients in Spain participated. The measures used were the newly created scale of Perceived Organizational Justice in Care Services (PJustCS/PJustAS) and scales of patients' Satisfaction, Trust and Global Justice. Factor Analyses supported the four dimensional structure of the instrument for each group. Multigroup CFA substantiated invariant factor loadings and invariant structural models across both samples, hence, supporting that the instrument is applicable in its two versions: English and Spanish. Validation results showed expected positive relations of OJ with patients' satisfaction, trust in clinicians and global perceived justice. These results point out the importance of health care customers' perceived organizational justice in the explanation of health care dynamics. The scale has desirable psychometric properties and shows adequate validity, contributing to the potential development of the area. Copyright © 2013 Elsevier Ltd. All rights reserved.

  11. Geochemical results from stream-water and stream-sediment samples collected in Colorado and New Mexico

    USGS Publications Warehouse

    Hageman, Philip L.; Todd, Andrew S.; Smith, Kathleen S.; DeWitt, Ed; Zeigler, Mathew P.

    2013-01-01

    Scientists from the U.S. Geological Survey are studying the relationship between watershed lithology and stream-water chemistry. As part of this effort, 60 stream-water samples and 43 corresponding stream-sediment samples were collected in 2010 and 2011 from locations in Colorado and New Mexico. Sample sites were selected from small to midsize watersheds composed of a high percentage of one rock type or geologic unit. Stream-water and stream-sediment samples were collected, processed, preserved, and analyzed in a consistent manner. This report releases geochemical data for this phase of the study.

  12. Validation of the Short Form of the Career Development Inventory with an Iranian High School Sample

    ERIC Educational Resources Information Center

    Sadeghi, Ahmad; Baghban, Iran; Bahrami, Fatemeh; Ahmadi, Ahmad; Creed, Peter

    2011-01-01

    A short 33-item form of the Career Development Inventory was validated on a sample of 310 Iranian high school students. Factor analysis indicated that attitude and cognitive subscale items loaded on their respective factors, and that internal reliability coefficients at all levels were satisfactory to good. Support for validity was demonstrated by…

  13. Reliability and validity of the Modified Erikson Psychosocial Stage Inventory in diverse samples.

    PubMed

    Leidy, N K; Darling-Fisher, C S

    1995-04-01

    The Modified Erikson Psychosocial Stage Inventory (MEPSI) is a relatively simple survey measure designed to assess the strength of psychosocial attributes that arise from progression through Erikson's eight stages of development. The purpose of this study was to employ secondary analysis to evaluate the internal-consistency reliability and construct validity of the MEPSI across four diverse samples: healthy young adults, hemophilic men, healthy older adults, and older adults with chronic obstructive pulmonary disease. Special attention was given to the performance of the measure across gender, with exploratory analyses examining possible age cohort and health status effects. Internal-consistency estimates for the aggregate measure were high, whereas subscale reliability levels varied across age groups. Construct validity was supported across samples. Gender, cohort, and health effects offered interesting psychometric and theoretical insights and direction for further research. Findings indicated that the MEPSI might be a useful instrument for operationalizing and testing Eriksonian developmental theory in adults.

  14. Sampling Participants’ Experience in Laboratory Experiments: Complementary Challenges for More Complete Data Collection

    PubMed Central

    McAuliffe, Alan; McGann, Marek

    2016-01-01

    Speelman and McGann’s (2013) examination of the uncritical way in which the mean is often used in psychological research raises questions both about the average’s reliability and its validity. In the present paper, we argue that interrogating the validity of the mean involves, amongst other things, a better understanding of the person’s experiences, the meaning of their actions, at the time that the behavior of interest is carried out. Recently emerging approaches within Psychology and Cognitive Science have argued strongly that experience should play a more central role in our examination of behavioral data, but the relationship between experience and behavior remains very poorly understood. We outline some of the history of the science on this fraught relationship, as well as arguing that contemporary methods for studying experience fall into one of two categories. “Wide” approaches tend to incorporate naturalistic behavior settings, but sacrifice accuracy and reliability in behavioral measurement. “Narrow” approaches maintain controlled measurement of behavior, but involve too specific a sampling of experience, which obscures crucial temporal characteristics. We therefore argue for a novel, mid-range sampling technique, that extends Hurlburt’s descriptive experience sampling, and adapts it for the controlled setting of the laboratory. This controlled descriptive experience sampling may be an appropriate tool to help calibrate both the mean and the meaning of an experimental situation with one another. PMID:27242588

  15. Archival policies and collections database for the Woods Hole Science Center's marine sediment samples

    USGS Publications Warehouse

    Buczkowski, Brian J.; Kelsey, Sarah A.

    2007-01-01

    The Woods Hole Science Center of the U.S. Geological Survey (USGS) has been an active member of the Woods Hole research community, Woods Hole, Massachusetts, for over 40 years. In that time there have been many projects that involved the collection of sediment samples conducted by USGS scientists and technicians for the research and study of seabed environments and processes. These samples were collected at sea or near shore and then brought back to the Woods Hole Science Center (WHSC) for analysis. While at the center, samples are stored in ambient temperature, refrigerated and freezing conditions ranging from +2º Celsius to -18º Celsius, depending on the best mode of preparation for the study being conducted or the duration of storage planned for the samples. Recently, storage methods and available storage space have become a major concern at the WHSC. The core and sediment archive program described herein has been initiated to set standards for the management, methods, and duration of sample storage. A need has arisen to maintain organizational consistency and define storage protocol. This handbook serves as a reference and guide to all parties interested in using and accessing the WHSC's sample archive and also defines all the steps necessary to construct and maintain an organized collection of geological samples. It answers many questions as to the way in which the archive functions.

  16. Quality Control and Analysis of Microphysical Data Collected in TRMM Aircraft Validation Experiments

    NASA Technical Reports Server (NTRS)

    Heymsfield, Andrew J.

    2004-01-01

    This report summarizes our efforts on the funded project 'Quality Control and Analysis of Microphysical Data Collected in TRMM Airborne Validation Experiments', NASA NAG5-9663, Andrew Heymsfield, P. I. We begin this report by summarizing our activities in FY2000-FY2004. We then present some highlights of our work. The last part of the report lists the publications that have resulted from our funding through this grant.

  17. Data Validation Package May 2015, Groundwater Sampling at the Shoal, Nevada, Site

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Findlay, Rick; Kautsky, Mark

    The U.S. Department of Energy Office of Legacy Management conducted annual sampling at the Shoal, Nevada, Site (Shoal) in May 2015. Groundwater samples were collected from wells MV-1, MV-2, MV-3, MV-4, MV-5, H-3, HC-1, HC-2d, HC-3, HC-4, HC-5, HC-6, HC-7, HC-8, and HS-1. Sampling was conducted as specified in the Sampling and Analysis Plan for US. Department of Energy Office of Legacy Management Sites (LMS/PRO/S04351, continually updated, http://energy.gov/lm/downloads/sampling-and-analysis-plan-us-department-energy­ office-legacy-management-sites). Monitoring wells MV-1, MV-2, MV-3, MV-4, MV-5, HC-2d, HC-4, HC-5, HC-7, HC-8, and HS-1 were purged prior to sampling using dedicated submersible pumps. At least one well casing volume was removed,more » and field parameters (temperature, pH, and specific conductance) were allowed to stabilize before samples were collected. Samples were collected from wells H-3, HC-1, HC-3, and HC-6 using a depth-specific bailer because these wells are not completed with dedicated submersible pumps. Samples were submitted under Requisition Index Number (RIN) 15057042 to ALS Laboratory Group in Fort Collins, Colorado, for the determination of bromide, gross alpha, gross beta, tritium, uranium isotopes, and total uranium (by mass); and under RIN 15057043 to the University of Arizona for the determination of carbon-14 and iodine-129. A duplicate sample from location MV-2 was included with RIN 15057042. The laboratory results from the 2015 sampling event are consistent with those of previous years with the exception of sample results from well HC-4. This well continues to be the only well with tritium concentrations above the laboratory’s minimum detectable concentration which is attributed to the wells proximity to the nuclear detonation. The tritium concentration (731 picocuries per liter [pCi/L]) is consistent with past results and is below the U.S. Environmental Protection Agency's (EPA) maximum contaminant level (MCL) of 20,000 p

  18. Validation of the Sexual Orientation Microaggression Inventory In Two Diverse Samples of LGBTQ Youth

    PubMed Central

    Swann, Gregory; Minshew, Reese; Newcomb, Michael E.; Mustanski, Brian

    2016-01-01

    Critical race theory asserts that microaggressions, or low-level, covert acts of aggression, are commonplace in the lives of people of color. These theorists also assert a taxonomy of microaggressions, which includes “microassaults,” “microinsults,” and “microinvalidations.” The theory of microaggressions has been adopted by researchers of LGBTQ communities. This study investigated the three-factor taxonomy as it relates to a diverse sample of LGBTQ youth using the newly developed Sexual Orientation Microaggression Inventory (SOMI). Exploratory factor analysis was used to determine the number of factors that exist in SOMI in a sample of 206 LGBTQ-identifying youth. Follow up confirmatory factor analyses (CFAs) were conducted in order to compare single factor, unrestricted four factor, second order, and bi-factor models in a separate sample of 363 young men who have sex with men. The best fitting model was used to predict victimization, depressive symptoms, and depression diagnosis in order to test validity. The best fitting model was a bi-factor model utilizing 19 of the original 26 items with a general factor and four specific factors representing anti-gay attitudes (“microinsults”), denial of homosexuality, heterosexism (“microinvalidations”), and societal disapproval (“microassaults”). Reliability analyses found that the majority of reliable variance was accounted for by the general factor. The general factor was a significant predictor of victimization and depressive symptoms, as well as unrelated to social desirability, suggesting convergent, criterion-related, and discriminant validity. SOMI emerged as a scale with evidence of validity for assessing exposure to microaggressions in a diverse sample of LGBTQ youth. PMID:27067241

  19. COLLECTING URINE SAMPLES FROM YOUNG CHILDREN USING GAUZE FOR PESTICIDE STUDIES

    EPA Science Inventory

    To estimate pesticide exposure, urine samples are often needed to analyze pesticide metabolites. However, this is difficult for children wearing diapers because simple and feasible techniques suitable for field collection are not available. The objectives of this study were to te...

  20. Validating the Orientations to Happiness Scale in a Chinese Sample of University Students

    ERIC Educational Resources Information Center

    Chen, Guo-Hai

    2010-01-01

    This paper examined the reliability and validity of the Orientation to Happiness Scale with a sample of Chinese correspondents. Chinese translation of the Orientation to Happiness Scale, Satisfaction with Life Scale, Temporal Satisfaction with Life Scale, and General Life Satisfaction Scale, were administered to 671 Chinese university students…

  1. Multidimensional Motivation and Engagement for Writing: Construct Validation with a Sample of Boys

    ERIC Educational Resources Information Center

    Collie, Rebecca J.; Martin, Andrew J.; Curwood, Jen Scott

    2016-01-01

    Given recent concerns around boys' literacy, this study examined multidimensional writing motivation and engagement among boys. We explored internal and external validity of 11 adaptive (e.g. self-efficacy for writing) and maladaptive (e.g. disengagement from writing) factors of writing motivation and engagement. The sample comprised 781 male…

  2. Incremental Validity of the Durand Adaptive Psychopathic Traits Questionnaire Above Self-Report Psychopathy Measures in Community Samples.

    PubMed

    Durand, Guillaume

    2018-05-03

    Although highly debated, the notion of the existence of an adaptive side to psychopathy is supported by some researchers. Currently, 2 instruments assessing psychopathic traits include an adaptive component, which might not cover the full spectrum of adaptive psychopathic traits. The Durand Adaptive Psychopathic Traits Questionnaire (DAPTQ; Durand, 2017 ) is a 41-item self-reported instrument assessing adaptive traits known to correlate with the psychopathic personality. In this study, I investigated in 2 samples (N = 263 and N = 262) the incremental validity of the DAPTQ over the Psychopathic Personality Inventory-Short Form (PPI-SF) and the Triarchic Psychopathy Measure (TriPM) using multiple criterion measures. Results showed that the DAPTQ significantly increased the predictive validity over the PPI-SF on 5 factors of the HEXACO. Additionally, the DAPTQ provided incremental validity over both the PPI-SF and the TriPM on measures of communication adaptability, perceived stress, and trait anxiety. Overall, these results support the validity of the DAPTQ in community samples. Directions for future studies to further validate the DAPTQ are discussed.

  3. Successful collection of stool samples for microbiome analyses from a large community-based population of elderly men.

    PubMed

    Abrahamson, Melanie; Hooker, Elizabeth; Ajami, Nadim J; Petrosino, Joseph F; Orwoll, Eric S

    2017-09-01

    The relationship of the gastrointestinal microbiome to health and disease is of major research interest, including the effects of the gut microbiota on age related conditions. Here we report on the outcome of a project to collect stool samples on a large number of community dwelling elderly men using the OMNIgene-GUT stool/feces collection kit (OMR-200, DNA Genotek, Ottawa, Canada). Among 1,328 men who were eligible for stool collection, 982 (74%) agreed to participate and 951 submitted samples. The collection process was reported to be acceptable, almost all samples obtained were adequate, the process of sample handling by mail was uniformly successful. The DNA obtained provided excellent results in microbiome analyses, yielding an abundance of species and a diversity of taxa as would be predicted. Our results suggest that population studies of older participants involving remote stool sample collection are feasible. These approaches would allow large scale research projects of the association of the gut microbiota with important clinical outcomes.

  4. Guidelines for collection and field analysis of ground-water samples for selected unstable constituents

    USGS Publications Warehouse

    Wood, Warren W.

    1976-01-01

    The unstable nature of many chemical and physical constituents in ground water requires special collection procedures and field analysis immediately after collection. This report describes the techniques and equipment commonly used m the collection and field analysis of samples for pH, temperature, carbonate, bicarbonate, specific conductance, Eh, and dissolved oxygen.

  5. Internal validation of the GlobalFiler™ Express PCR Amplification Kit for the direct amplification of reference DNA samples on a high-throughput automated workflow.

    PubMed

    Flores, Shahida; Sun, Jie; King, Jonathan; Budowle, Bruce

    2014-05-01

    The GlobalFiler™ Express PCR Amplification Kit uses 6-dye fluorescent chemistry to enable multiplexing of 21 autosomal STRs, 1 Y-STR, 1 Y-indel and the sex-determining marker amelogenin. The kit is specifically designed for processing reference DNA samples in a high throughput manner. Validation studies were conducted to assess the performance and define the limitations of this direct amplification kit for typing blood and buccal reference DNA samples on various punchable collection media. Studies included thermal cycling sensitivity, reproducibility, precision, sensitivity of detection, minimum detection threshold, system contamination, stochastic threshold and concordance. Results showed that optimal amplification and injection parameters for a 1.2mm punch from blood and buccal samples were 27 and 28 cycles, respectively, combined with a 12s injection on an ABI 3500xL Genetic Analyzer. Minimum detection thresholds were set at 100 and 120RFUs for 27 and 28 cycles, respectively, and it was suggested that data from positive amplification controls provided a better threshold representation. Stochastic thresholds were set at 250 and 400RFUs for 27 and 28 cycles, respectively, as stochastic effects increased with cycle number. The minimum amount of input DNA resulting in a full profile was 0.5ng, however, the optimum range determined was 2.5-10ng. Profile quality from the GlobalFiler™ Express Kit and the previously validated AmpFlSTR(®) Identifiler(®) Direct Kit was comparable. The validation data support that reliable DNA typing results from reference DNA samples can be obtained using the GlobalFiler™ Express PCR Amplification Kit. Copyright © 2014 Elsevier Ireland Ltd. All rights reserved.

  6. The presentation and preliminary validation of KIWEST using a large sample of Norwegian university staff.

    PubMed

    Innstrand, Siw Tone; Christensen, Marit; Undebakke, Kirsti Godal; Svarva, Kyrre

    2015-12-01

    The aim of the present paper is to present and validate a Knowledge-Intensive Work Environment Survey Target (KIWEST), a questionnaire developed for assessing the psychosocial factors among people in knowledge-intensive work environments. The construct validity and reliability of the measurement model where tested on a representative sample of 3066 academic and administrative staff working at one of the largest universities in Norway. Confirmatory factor analysis provided initial support for the convergent validity and internal consistency of the 30 construct KIWEST measurement model. However, discriminant validity tests indicated that some of the constructs might overlap to some degree. Overall, the KIWEST measure showed promising psychometric properties as a psychosocial work environment measure. © 2015 the Nordic Societies of Public Health.

  7. Impact of collection container material and holding times on sample integrity for mercury and methylmercury in water

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Riscassi, Ami L; Miller, Carrie L; Brooks, Scott C

    Mercury (Hg) and methylmercury (MeHg) concentrations in streamwater can vary on short timescales (hourly or less) during storm flow and on a diel cycle; the frequency and timing of sampling required to accurately characterize these dynamics may be difficult to accomplish manually. Automated sampling can assist in sample collection; however use has been limited for Hg and MeHg analysis due to stability concerns of trace concentrations during extended storage times. We examined the viability of using automated samplers with disposable low-density polyethylene (LDPE) sample bags to collect industrially contaminated streamwater for unfiltered and filtered Hg and MeHg analysis. Specifically wemore » investigated the effect of holding times ranging from hours to days on streamwater collected during baseflow and storm flow. Unfiltered and filtered Hg and MeHg concentrations decreased with increases in time prior to sample processing; holding times of 24 hours or less resulted in concentration changes (mean 11 7% different) similar to variability in duplicates collected manually during analogous field conditions (mean 7 10% different). Comparisons of samples collected with manual and automated techniques throughout a year for a wide range of stream conditions were also found to be similar to differences observed between duplicate grab samples. These results demonstrate automated sampling into LDPE bags with holding times of 24 hours or less can be effectively used to collect streamwater for Hg and MeHg analysis, and encourage the testing of these materials and methods for implementation in other aqueous systems where high-frequency sampling is warranted.« less

  8. Construct Validity Evidence for Single-Response Items to Estimate Physical Activity Levels in Large Sample Studies

    ERIC Educational Resources Information Center

    Jackson, Allen W.; Morrow, James R., Jr.; Bowles, Heather R.; FitzGerald, Shannon J.; Blair, Steven N.

    2007-01-01

    Valid measurement of physical activity is important for studying the risks for morbidity and mortality. The purpose of this study was to examine evidence of construct validity of two similar single-response items assessing physical activity via self-report. Both items are based on the stages of change model. The sample was 687 participants (men =…

  9. System for Earth Sample Registration SESAR: Services for IGSN Registration and Sample Metadata Management

    NASA Astrophysics Data System (ADS)

    Chan, S.; Lehnert, K. A.; Coleman, R. J.

    2011-12-01

    SESAR, the System for Earth Sample Registration, is an online registry for physical samples collected for Earth and environmental studies. SESAR generates and administers the International Geo Sample Number IGSN, a unique identifier for samples that is dramatically advancing interoperability amongst information systems for sample-based data. SESAR was developed to provide the complete range of registry services, including definition of IGSN syntax and metadata profiles, registration and validation of name spaces requested by users, tools for users to submit and manage sample metadata, validation of submitted metadata, generation and validation of the unique identifiers, archiving of sample metadata, and public or private access to the sample metadata catalog. With the development of SESAR v3, we placed particular emphasis on creating enhanced tools that make metadata submission easier and more efficient for users, and that provide superior functionality for users to manage metadata of their samples in their private workspace MySESAR. For example, SESAR v3 includes a module where users can generate custom spreadsheet templates to enter metadata for their samples, then upload these templates online for sample registration. Once the content of the template is uploaded, it is displayed online in an editable grid format. Validation rules are executed in real-time on the grid data to ensure data integrity. Other new features of SESAR v3 include the capability to transfer ownership of samples to other SESAR users, the ability to upload and store images and other files in a sample metadata profile, and the tracking of changes to sample metadata profiles. In the next version of SESAR (v3.5), we will further improve the discovery, sharing, registration of samples. For example, we are developing a more comprehensive suite of web services that will allow discovery and registration access to SESAR from external systems. Both batch and individual registrations will be possible

  10. Validity of a portable urine refractometer: the effects of sample freezing.

    PubMed

    Sparks, S Andy; Close, Graeme L

    2013-01-01

    The use of portable urine osmometers is widespread, but no studies have assessed the validity of this measurement technique. Furthermore, it is unclear what effect freezing has on osmolality. One-hundred participants of mean (±SD) age 25.1 ± 7.6 years, height 1.77 ± 0.1 m and weight 77.1 ± 10.8 kg provided single urine samples that were analysed using freeze point depression (FPD) and refractometry (RI). Samples were then frozen at -80°C (n = 81) and thawed prior to re-analysis. Differences between methods and freezing were determined using Wilcoxon's signed rank test. Relationships between measurements were assessed using intraclass correlation coefficients (ICC) and typical error of estimate (TE). Osmolality was lower (P = 0.001) using RI (634.2 ± 339.8 mOsm · kgH2O(-1)) compared with FPD (656.7 ± 334.1 mOsm · kgH2O(-1)) but the TE was trivial (0.17). Freezing significantly reduced mean osmolality using FPD (656.7 ± 341.1 to 606.5 ± 333.4 mOsm · kgH2O(-1); P < 0.001), but samples were still highly related following freezing (ICC, r = 0.979, P < 0.001, CI = 0.993-0.997; TE = 0.15; and r=0.995, P < 0.001, CI = 0.967-0.986; TE = 0.07 for RI and FPD respectively). Despite mean differences between methods and as a result of freezing, such differences are physiologically trivial. Therefore, the use of RI appears to be a valid measurement tool to determine urine osmolality.

  11. The Validity of the Five-Factor Model Prototypes for Personality Disorders in Two Clinical Samples

    ERIC Educational Resources Information Center

    Miller, Joshua D.; Reynolds, Sarah K.; Pilkonis, Paul A.

    2004-01-01

    The authors examined the validity of D. R. Lynam and T. A. Widiger's (2001) prototypes for personality disorders (PDs) derived from the facets of the 5-factor model (FFM) of personality in 2 clinical samples. In the 1st sample (N = 94), there was good agreement between the prototypes generated by experts and the profiles reported by patients.…

  12. Validity and Reliability of the Turkish Chronic Pain Acceptance Questionnaire

    PubMed

    Akmaz, Hazel Ekin; Uyar, Meltem; Kuzeyli Yıldırım, Yasemin; Akın Korhan, Esra

    2018-05-29

    Pain acceptance is the process of giving up the struggle with pain and learning to live a worthwhile life despite it. In assessing patients with chronic pain in Turkey, making a diagnosis and tracking the effectiveness of treatment is done with scales that have been translated into Turkish. However, there is as yet no valid and reliable scale in Turkish to assess the acceptance of pain. To validate a Turkish version of the Chronic Pain Acceptance Questionnaire developed by McCracken and colleagues. Methodological and cross sectional study. A simple randomized sampling method was used in selecting the study sample. The sample was composed of 201 patients, more than 10 times the number of items examined for validity and reliability in the study, which totaled 20. A patient identification form, the Chronic Pain Acceptance Questionnaire, and the Brief Pain Inventory were used to collect data. Data were collected by face-to-face interviews. In the validity testing, the content validity index was used to evaluate linguistic equivalence, content validity, construct validity, and expert views. In reliability testing of the scale, Cronbach’s α coefficient was calculated, and item analysis and split-test reliability methods were used. Principal component analysis and varimax rotation were used in factor analysis and to examine factor structure for construct concept validity. The item analysis established that the scale, all items, and item-total correlations were satisfactory. The mean total score of the scale was 21.78. The internal consistency coefficient was 0.94, and the correlation between the two halves of the scale was 0.89. The Chronic Pain Acceptance Questionnaire, which is intended to be used in Turkey upon confirmation of its validity and reliability, is an evaluation instrument with sufficient validity and reliability, and it can be reliably used to examine patients’ acceptance of chronic pain.

  13. Y chromosome DNA in cervicovaginal self-collected samples of childbearing age women: Implications for epitheliotropic sexually transmitted infections?

    PubMed

    Silva, Jani; Cerqueira, Fátima; Medeiros, Rui

    2015-10-15

    Assuming a possible association between Y chromosome (Yc)-DNA and sexually transmitted infection (STI) transmission rate, could Yc-DNA be related to an increased prevalence of Human Papillomavirus (HPV), Herpes Simplex Virus (HSV-1/2) and Chlamydia trachomatis (CT)? Could Yc-DNA be used to validate self-reported condom use and sexual behaviors? Cervicovaginal (CV) self-collected samples of 612 Portuguese women at childbearing age were tested for Yc, HPV, HSV-1/2 and CT by polymerase chain reaction (PCR). The prevalence of Yc, HPV, CT and HSV-2 was 4.9%, 17.6%, 11.6% and 2.8%, respectively. There was a statistically significant trend for increased Yc-DNA prevalence in HPV positive samples [odds ratio (OR) 2.35, 95% confidence interval (CI) 1.03-5.31] and oral contraceptive (OC) use (OR 4.73, 95% CI 1.09-20.44). A protective effect of condom use was observed in Yc-DNA detection (OR 0.40, 95% CI 0.18-0.89). No statistically significant difference was found between Yc-DNA, CT and HSV-2 infection. HPV infection risk increased with age (>20 years), young age at first sexual intercourse (FSI) (≤18 years), >1 lifetime sexual partner (LSP) and OC use. Risk factors for CT infection were young age (≤20 years) and young age at FSI (≤18 years). HSV-2 infection risk increased with age (>20 years) and >1 LSP. Considering the prevalence of HPV and CT in Yc positive samples, we hypothesize a current infection due to recent sexual activity. The study of Yc PCR may add information as (i) a predictor of STI transmission and (ii) an indicative biomarker to validate self-reported condom use. Copyright © 2015. Published by Elsevier Inc.

  14. The DSM-5 social anxiety disorder severity scale: Evidence of validity and reliability in a clinical sample.

    PubMed

    LeBeau, Richard T; Mesri, Bita; Craske, Michelle G

    2016-10-30

    With DSM-5, the APA began providing guidelines for anxiety disorder severity assessment that incorporates newly developed self-report scales. The scales share a common template, are brief, and are free of copyright restrictions. Initial validation studies have been promising, but the English-language versions of the scales have not been formally validated in clinical samples. Forty-seven individuals with a principal diagnosis of Social Anxiety Disorder (SAD) completed a diagnostic assessment, as well as the DSM-5 SAD severity scale and several previously validated measures. The scale demonstrated internal consistency, convergent validity, and discriminant validity. The next steps in the validation process are outlined. Copyright © 2016 Elsevier Ireland Ltd. All rights reserved.

  15. Analysis of Samples Collected from the Surface of Interim Storage Canisters at Calvert Cliffs in June 2017: Revision 01.

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Bryan, Charles R.; Schindelholz, Eric John

    In June 2017, dust and salt samples were collected from the surface of Spent Nuclear Fuel (SNF) dry storage canisters at the Calvert Cliffs Nuclear Power Plant. The samples were delivered to Sandia National laboratories for analysis. Two types of samples were collected: filter-backed Scotch-Brite TM pads were used to collect dry dust samples for characterization of salt and dust morphologies and distributions; and Saltsmart TM test strips were used to collect soluble salts for determining salt surface loadings per unit area. After collection, the samples were sealed into plastic sleeves for shipping. Condensation within the sleeves containing the Scotch-Britemore » TM samples remobilized the salts, rendering them ineffective for the intended purpose, and also led to mold growth, further compromising the samples; for these reasons, the samples were not analyzed. The SaltSmart TM samples were unaffected and were analyzed by ion chromatography for major anions and cations. The results of those analyses are presented here.« less

  16. Optimization of sampling parameters for collection and preconcentration of alveolar air by needle traps.

    PubMed

    Filipiak, Wojciech; Filipiak, Anna; Ager, Clemens; Wiesenhofer, Helmut; Amann, Anton

    2012-06-01

    The approach for breath-VOCs' collection and preconcentration by applying needle traps was developed and optimized. The alveolar air was collected from only a few exhalations under visual control of expired CO(2) into a large gas-tight glass syringe and then warmed up to 45 °C for a short time to avoid condensation. Subsequently, a specially constructed sampling device equipped with Bronkhorst® electronic flow controllers was used for automated adsorption. This sampling device allows time-saving collection of expired/inspired air in parallel onto three different needle traps as well as improvement of sensitivity and reproducibility of NT-GC-MS analysis by collection of relatively large (up to 150 ml) volume of exhaled breath. It was shown that the collection of alveolar air derived from only a few exhalations into a large syringe followed by automated adsorption on needle traps yields better results than manual sorption by up/down cycles with a 1 ml syringe, mostly due to avoided condensation and electronically controlled stable sample flow rate. The optimal profile and composition of needle traps consists of 2 cm Carbopack X and 1 cm Carboxen 1000, allowing highly efficient VOCs' enrichment, while injection by a fast expansive flow technique requires no modifications in instrumentation and fully automated GC-MS analysis can be performed with a commercially available autosampler. This optimized analytical procedure considerably facilitates the collection and enrichment of alveolar air, and is therefore suitable for application at the bedside of critically ill patients in an intensive care unit. Due to its simplicity it can replace the time-consuming sampling of sufficient breath volume by numerous up/down cycles with a 1 ml syringe.

  17. Examining Returned Samples in their Collection Tubes Using Synchrotron Radiation-Based Techniques

    NASA Astrophysics Data System (ADS)

    Schoonen, M. A.; Hurowitz, J. A.; Thieme, J.; Dooryhee, E.; Fogelqvist, E.; Gregerson, J.; Farley, K. A.; Sherman, S.; Hill, J.

    2018-04-01

    Synchrotron radiation-based techniques can be leveraged for triaging and analysis of returned samples before unsealing collection tubes. Proof-of-concept measurements conducted at Brookhaven National Lab's National Synchrotron Light Source-II.

  18. A Feasibility Study of the Collection of Unscheduled Maintenance Data Using Statistical Sampling Techniques.

    DTIC Science & Technology

    1985-09-01

    TECHNIQUES THESIS Robert A. Heinlein Captain, USAF AFIT/GLM/LSM/855-32.- _ DTIC MU’noN ’ST.,TEMENT A A-ZELECTE Approved lt public teleo*I Al \\ Z #&N0V21...343" A FEASIBILITY STUDY OF THE COLLECTION OF UNSCHEDULED MAINTENANCE DATA USING STrATISTICAL SAMPLING TECHNIQUES THESIS L .9 Robe-t A. Heinlein...a AFIT/GLM/LSM/85S-32 A FEASIBILITY STUDY OF THE COLLECTION OF UNSCHEDULED MAINTENANCE DATA USING STATISTICAL SAMPLING TECHNIQUES THESIS

  19. Three-Step Validation of Exercise Behavior Processes of Change in an Adolescent Sample

    ERIC Educational Resources Information Center

    Rhodes, Ryan E.; Berry, Tanya; Naylor, Patti-Jean; Higgins, S. Joan Wharf

    2004-01-01

    Though the processes of change are conceived as the core constructs of the transtheoretical model (TTM), few researchers have examined their construct validity in the physical activity domain. Further, only 1 study was designed to investigate the processes of change in an adolescent sample. The purpose of this study was to examine the exercise…

  20. Factorial Validity and Invariance of the GHQ-12 among Clinical and Nonclinical Samples

    ERIC Educational Resources Information Center

    Fernandes, Helder Miguel; Vasconcelos-Raposo, Jose

    2013-01-01

    The purpose of this study was to examine the internal reliability, factorial validity, and measurement invariance of a Brazilian-Portuguese version of the General Health Questionnaire-12 (GHQ-12) across clinical and nonclinical groups. The clinical sample consisted of 228 chronic hemodialysis patients (41.7% female), with a mean age of 48.23 (SD =…

  1. School Anxiety Inventory: Reliability and Validity Evidence in a Sample of Slovenian Adolescents

    ERIC Educational Resources Information Center

    Levpušcek, Melita Puklek; Inglés, Candido J.; Marzo, Juan C.; García-Fernández, Jose M.

    2015-01-01

    The purpose of this study was to examine the reliability and validity of the School Anxiety Inventory (SAI) using a sample of 646 Slovenian adolescents (48% boys), ranging in age from 12 to 19 years. Single confirmatory factor analyses replicated the correlated four-factor structure of scores on the SAI for anxiety-provoking school situations…

  2. Use of self-collected capillary blood samples for islet autoantibody screening in relatives: a feasibility and acceptability study.

    PubMed

    Liu, Y; Rafkin, L E; Matheson, D; Henderson, C; Boulware, D; Besser, R E J; Ferrara, C; Yu, L; Steck, A K; Bingley, P J

    2017-07-01

    To evaluate the feasibility of using self-collected capillary blood samples for islet autoantibody testing to identify risk in relatives of people with Type 1 diabetes. Participants were recruited via the observational TrialNet Pathway to Prevention study, which screens and monitors relatives of people with Type 1 diabetes for islet autoantibodies. Relatives were sent kits for capillary blood collection, with written instructions, an online instructional video link and a questionnaire. Sera from capillary blood samples were tested for autoantibodies to glutamic acid decarboxylase, islet antigen-2, insulin and zinc transporter 8. 'Successful' sample collection was defined as obtaining sufficient volume and quality to provide definitive autoantibody results, including confirmation of positive results by repeat assay. In 240 relatives who returned samples, the median (range) age was 15.5 (1-49) years and 51% were male. Of these samples, 98% were sufficient for glutamic acid decarboxylase, islet antigen-2 and zinc transporter 8 autoantibody testing and 84% for insulin autoantibody testing and complete autoantibody screen. The upper 90% confidence bound for unsuccessful collection was 4.4% for glutamic acid decarboxylase, islet antigen-2 and/or zinc transporter 8 autoantibody assays, and 19.3% for insulin autoantibodies. Despite 43% of 220 questionnaire respondents finding capillary blood collection uncomfortable or painful, 82% preferred home self-collection of capillary blood samples compared with outpatient venepuncture (90% of those aged <8 years, 83% of those aged 9-18 years and 73% of those aged >18 years). The perceived difficulty of collecting capillary blood samples did not affect success rate. Self-collected capillary blood sampling offers a feasible alternative to venous sampling, with the potential to facilitate autoantibody screening for Type 1 diabetes risk. © 2017 Diabetes UK.

  3. Combining Laser Ablation/Liquid Phase Collection Surface Sampling and High-Performance Liquid Chromatography Electrospray Ionization Mass Spectrometry

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Ovchinnikova, Olga S; Kertesz, Vilmos; Van Berkel, Gary J

    This paper describes the coupling of ambient pressure transmission geometry laser ablation with a liquid phase sample collection method for surface sampling and ionization with subsequent mass spectral analysis. A commercially available autosampler was adapted to produce a liquid droplet at the end of the syringe injection needle while in close proximity to the surface to collect the sample plume produced by laser ablation. The sample collection was followed by either flow injection or a high performance liquid chromatography (HPLC) separation of the extracted components and detection with electrospray ionization mass spectrometry (ESI-MS). To illustrate the analytical utility of thismore » coupling, thin films of a commercial ink sample containing rhodamine 6G and of mixed isobaric rhodamine B and 6G dyes on glass microscope slides were analyzed. The flow injection and HPLC/ESI-MS analysis revealed successful laser ablation, capture and, with HPLC, the separation of the two compounds. The ablated circular area was about 70 m in diameter for these experiments. The spatial sampling resolution afforded by the laser ablation, as well as the ability to use sample processing methods like HPLC between the sample collection and ionization steps, makes this combined surface sampling/ionization technique a highly versatile analytical tool.« less

  4. Control of the positional relationship between a sample collection instrument and a surface to be analyzed during a sampling procedure using a laser sensor

    DOEpatents

    Van Berkel, Gary J [Clinton, TN; Kertesz, Vilmos [Knoxville, TN

    2012-02-21

    A system and method utilizes distance-measuring equipment including a laser sensor for controlling the collection instrument-to-surface distance during a sample collection process for use, for example, with mass spectrometric detection. The laser sensor is arranged in a fixed positional relationship with the collection instrument, and a signal is generated by way of the laser sensor which corresponds to the actual distance between the laser sensor and the surface. The actual distance between the laser sensor and the surface is compared to a target distance between the laser sensor and the surface when the collection instrument is arranged at a desired distance from the surface for sample collecting purposes, and adjustments are made, if necessary, so that the actual distance approaches the target distance.

  5. The focus on sample quality: Influence of colon tissue collection on reliability of qPCR data

    PubMed Central

    Korenkova, Vlasta; Slyskova, Jana; Novosadova, Vendula; Pizzamiglio, Sara; Langerova, Lucie; Bjorkman, Jens; Vycital, Ondrej; Liska, Vaclav; Levy, Miroslav; Veskrna, Karel; Vodicka, Pavel; Vodickova, Ludmila; Kubista, Mikael; Verderio, Paolo

    2016-01-01

    Successful molecular analyses of human solid tissues require intact biological material with well-preserved nucleic acids, proteins, and other cell structures. Pre-analytical handling, comprising of the collection of material at the operating theatre, is among the first critical steps that influence sample quality. The aim of this study was to compare the experimental outcomes obtained from samples collected and stored by the conventional means of snap freezing and by PAXgene Tissue System (Qiagen). These approaches were evaluated by measuring rRNA and mRNA integrity of the samples (RNA Quality Indicator and Differential Amplification Method) and by gene expression profiling. The collection procedures of the biological material were implemented in two hospitals during colon cancer surgery in order to identify the impact of the collection method on the experimental outcome. Our study shows that the pre-analytical sample handling has a significant effect on the quality of RNA and on the variability of qPCR data. PAXgene collection mode proved to be more easily implemented in the operating room and moreover the quality of RNA obtained from human colon tissues by this method is superior to the one obtained by snap freezing. PMID:27383461

  6. College Students' Perceptions of Collective Efficacy: Results from a Nonurban Sample

    ERIC Educational Resources Information Center

    Domoff, Sarah E.; Hayman, Jennifer; Tompsett, Carolyn J.

    2012-01-01

    Although the relationship between neighborhood characteristics and collective efficacy is well established in urban populations with community samples, it is unclear if this relationship holds in rural areas. The current study fills this gap by assessing the perceptions of adolescents from nonurban areas to examine the relationships between…

  7. A new device for collecting time-integrated water samples from springs and surface water bodies

    USGS Publications Warehouse

    Panno, S.V.; Krapac, I.G.; Keefer, D.A.

    1998-01-01

    A new device termed the 'seepage sampler' was developed to collect representative water samples from springs, streams, and other surface-water bodies. The sampler collects composite, time-integrated water samples over short (hours) or extended (weeks) periods without causing significant changes to the chemical composition of the samples. The water sample within the sampler remains at the ambient temperature of the water body and does not need to be cooled. Seepage samplers are inexpensive to construct and easy to use. A sampling program of numerous springs and/or streams can be designed at a relatively low cost through the use of these samplers. Transient solutes migrating through such flow systems, potentially unnoticed by periodic sampling, may be detected. In addition, the mass loading of solutes (e.g., agrichemicals) may be determined when seepage samplers are used in conjunction with discharge measurements.

  8. Paralytic shellfish toxins in phytoplankton and shellfish samples collected from the Bohai Sea, China.

    PubMed

    Liu, Yang; Yu, Ren-Cheng; Kong, Fan-Zhou; Chen, Zhen-Fan; Dai, Li; Gao, Yan; Zhang, Qing-Chun; Wang, Yun-Feng; Yan, Tian; Zhou, Ming-Jiang

    2017-02-15

    Phytoplankton and shellfish samples collected periodically from 5 representative mariculture zones around the Bohai Sea, Laishan (LS), Laizhou (LZ), Hangu (HG), Qinhuangdao (QHD) and Huludao (HLD), were analysed for paralytic shellfish toxins (PSTs) using an high-performance liquid chromatography (HPLC) method. Toxins were detected in 13 out of 20 phytoplankton samples, and N-sulfocarbamoyl toxins (C1/2) were predominant components of PSTs in phytoplankton samples with relatively low toxin content. However, two phytoplankton samples with high PST content collected from QHD and LS had unique toxin profiles characterized by high-potency carbamoyl toxins (GTX1/4) and decarbamoyl toxins (dcGTX2/3 and dcSTX), respectively. PSTs were commonly found in shellfish samples, and toxin content ranged from 0 to 27.6nmol/g. High level of PSTs were often found in scallops and clams. Shellfish from QHD in spring, and LZ and LS in autumn exhibited high risks of PST contamination. Copyright © 2016 Elsevier Ltd. All rights reserved.

  9. Methods for collection and analysis of aquatic biological and microbiological samples

    USGS Publications Warehouse

    Britton, L.J.; Greeson, P.E.

    1988-01-01

    Chapter A4, methods for collection and analyses of aquatic biological and microbiological samples, contains methods used by the U.S. Geological Survey to collect, preserve, and analyze waters to determine their biological and microbiological properties. Part 1 consists of detailed descriptions of more than 45 individual methods, including those for bacteria, phytoplankton, zooplankton, seston, periphyton, macrophytes, benthic invertebrates, fish and other vertebrates, cellular contents, productivity and bioassay. Each method is summarized, and the applications, interferences, apparatus, reagents, analyses, calculations, reporting of results, precisions, and references are given. Part 2 consists of a glossary. Part 3 is a list of taxonomic references. (USGS)

  10. The Development and Validation of the Client Expectations of Massage Scale

    PubMed Central

    Boulanger, Karen T.; Campo, Shelly; Glanville, Jennifer L.; Lowe, John B; Yang, Jingzhen

    2012-01-01

    Background: Although there is evidence that client expectations influence client outcomes, a valid and reliable scale for measuring the range of client expectations for both massage therapy and the behaviors of their massage therapists does not exist. Understanding how client expectations influence client outcomes would provide insight into how massage achieves its reported effects. Purpose: To develop and validate the Client Expectations of Massage Scale (CEMS), a measure of clients’ clinical, educational, interpersonal, and outcome expectations. Setting: Offices of licensed massage therapists in Iowa. Research Design: A practice-based research methodology was used to collect data from two samples of massage therapy clients. For Sample 1, 21 volunteer massage therapists collected data from their clients before the massage. Factor analysis was conducted to test construct validity and coefficient alpha was used to assess reliability. Correlational analyses with the CEMS, previous measures of client expectations, and the Life Orientation Test–Revised were examined to test the convergent and discriminant validity of the CEMS. For Sample 2, 24 massage therapists distributed study materials for clients to complete before and after a massage therapy session. Structural equation modeling was used to assess the construct, discriminant, and predictive validity of the CEMS. Participants: Sample 1 involved 320 and Sample 2 involved 321 adult massage clients. Intervention: Standard care provided by licensed massage therapists. Main Outcomes: Numeric Rating Scale for pain and Positive and Negative Affect Schedule–Revised (including the Serenity subscale). Results: The CEMS demonstrated good construct, convergent, discriminant and predictive validity, and adequate reliability. Client expectations were generally positive toward massage and their massage therapists. Positive outcome expectations had a positive effect on clients’ changes in pain and serenity. High

  11. The development and validation of the client expectations of massage scale.

    PubMed

    Boulanger, Karen T; Campo, Shelly; Glanville, Jennifer L; Lowe, John B; Yang, Jingzhen

    2012-01-01

    Although there is evidence that client expectations influence client outcomes, a valid and reliable scale for measuring the range of client expectations for both massage therapy and the behaviors of their massage therapists does not exist. Understanding how client expectations influence client outcomes would provide insight into how massage achieves its reported effects. To develop and validate the Client Expectations of Massage Scale (CEMS), a measure of clients' clinical, educational, interpersonal, and outcome expectations. Offices of licensed massage therapists in Iowa. A practice-based research methodology was used to collect data from two samples of massage therapy clients. For Sample 1, 21 volunteer massage therapists collected data from their clients before the massage. Factor analysis was conducted to test construct validity and coefficient alpha was used to assess reliability. Correlational analyses with the CEMS, previous measures of client expectations, and the Life Orientation Test-Revised were examined to test the convergent and discriminant validity of the CEMS. For Sample 2, 24 massage therapists distributed study materials for clients to complete before and after a massage therapy session. Structural equation modeling was used to assess the construct, discriminant, and predictive validity of the CEMS. Sample 1 involved 320 and Sample 2 involved 321 adult massage clients. Standard care provided by licensed massage therapists. Numeric Rating Scale for pain and Positive and Negative Affect Schedule-Revised (including the Serenity subscale). The CEMS demonstrated good construct, convergent, discriminant and predictive validity, and adequate reliability. Client expectations were generally positive toward massage and their massage therapists. Positive outcome expectations had a positive effect on clients' changes in pain and serenity. High interpersonal expectations had a negative effect on clients' changes in serenity. Client expectations contribute to

  12. CTEPP STANDARD OPERATING PROCEDURE FOR COLLECTION OF SOIL SAMPLES FOR PERSISTENT ORGANIC POLLUTANTS (SOP-2.20)

    EPA Science Inventory

    This SOP describes the method for collecting soil samples from the child's outdoor play area to measure for persistent organic pollutants. Soil samples are collected by scraping up the top 0.5 cm of soil in a 0.095 m2 (1 ft2) area in the middle of the child's play area.

  13. The Investigation of Construct Validity of Diagnostic and Statistical Manual of Mental Disorder-5 Personality Traits on Iranian sample with Antisocial and Borderline Personality Disorders.

    PubMed

    Amini, Mehdi; Pourshahbaz, Abbas; Mohammadkhani, Parvaneh; Ardakani, Mohammad-Reza Khodaie; Lotfi, Mozhgan

    2014-12-01

    The goal of this study was to examine the construct validity of the diagnostic and statistical manual of mental disorder-5 (DSM-5) conceptual model of antisocial and borderline personality disorders (PDs). More specifically, the aim was to determine whether the DSM-5 five-factor structure of pathological personality trait domains replicated in an independently collected sample that differs culturally from the derivation sample. This study was on a sample of 346 individuals with antisocial (n = 122) and borderline PD (n = 130), and nonclinical subjects (n = 94). Participants randomly selected from prisoners, out-patient, and in-patient clients. Participants were recruited from Tehran prisoners, and clinical psychology and psychiatry clinics of Razi and Taleghani Hospital, Tehran, Iran. The SCID-II-PQ, SCID-II, DSM-5 Personality Trait Rating Form (Clinician's PTRF) were used to diagnosis of PD and to assessment of pathological traits. The data were analyzed by exploratory factor analysis. Factor analysis revealed a 5-factor solution for DSM-5 personality traits. Results showed that DSM-5 has adequate construct validity in Iranian sample with antisocial and borderline PDs. Factors similar in number with the other studies, but different in the content. Exploratory factor analysis revealed five homogeneous components of antisocial and borderline PDs. That may represent personality, behavioral, and affective features central to the disorder. Furthermore, the present study helps understand the adequacy of DSM-5 dimensional approach to evaluation of personality pathology, specifically on Iranian sample.

  14. Clinical forensic sample collection techniques following consensual intercourse in volunteers - cervical canal brush compared to conventional swabs.

    PubMed

    Joki-Erkkilä, Minna; Tuomisto, Sari; Seppänen, Mervi; Huhtala, Heini; Ahola, Arja; Rainio, Juha; Karhunen, Pekka J

    2014-10-01

    The purpose of the research was to evaluate gynecological evidence collection techniques; the benefit of cervical canal brush sample compared to vaginal fornix and cervical swab samples and the time frame for detecting Y-chromosomal material QiAmp DNA Mini Kit(®) and Quantifiler Y Human Male DNA Quantification Kit(®) in adult volunteers following consensual intercourse. Eighty-four adult female volunteers following consensual intercourse were recruited for the study. By combining all sample collecting techniques, 81.0% of the volunteers were Y-DNA positive. Up to 60 h the conventional swab sampling techniques detected more Y-DNA positive samples when compared to the brush technique. However, after 60 h, the cervical canal brush sample technique showed its benefit by detecting 27.3% (6/22) of Y-DNA positive samples, which were Y-DNA negative in both conventional swab sampling techniques. By combining swab and brush techniques, 75% of the volunteers were still Y-DNA positive in 72-144 post-coital hours. The rate of measurable Y-DNA decreased approximately 3% per hour. Despite reported consensual intercourse, 6.8% (3/44) of volunteers were Y-DNA negative within 48 h. Y-DNA was not detected after 144 post-coital hours (6 days). In conclusion, the brush as a forensic evidence collection method may provide additional biological trace evidence from the cervical canal, although the best biological trace evidence collection can be obtained by combining all three sampling techniques. The time frame for gynecological forensic evidence sample collection should be considered to be at least a week if sexual violence is suspected. Copyright © 2014 Elsevier Ltd and Faculty of Forensic and Legal Medicine. All rights reserved.

  15. Improved explosive collection and detection with rationally assembled surface sampling materials

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Chouyyok, Wilaiwan; Bays, J. Timothy; Gerasimenko, Aleksandr A.

    Sampling and detection of trace explosives is a key analytical process in modern transportation safety. In this work we have explored some of the fundamental analytical processes for collection and detection of trace level explosive on surfaces with the most widely utilized system, thermal desorption IMS. The performance of the standard muslin swipe material was compared with chemically modified fiberglass cloth. The fiberglass surface was modified to include phenyl functional groups. When compared to standard muslin, the phenyl functionalized fiberglass sampling material showed better analyte release from the sampling material as well as improved response and repeatability from multiple usesmore » of the same swipe. The improved sample release of the functionalized fiberglass swipes resulted in a significant increase in sensitivity. Various physical and chemical properties were systematically explored to determine optimal performance. The results herein have relevance to improving the detection of other explosive compounds and potentially to a wide range of other chemical sampling and field detection challenges.« less

  16. Modeling and enhanced sampling of molecular systems with smooth and nonlinear data-driven collective variables.

    PubMed

    Hashemian, Behrooz; Millán, Daniel; Arroyo, Marino

    2013-12-07

    Collective variables (CVs) are low-dimensional representations of the state of a complex system, which help us rationalize molecular conformations and sample free energy landscapes with molecular dynamics simulations. Given their importance, there is need for systematic methods that effectively identify CVs for complex systems. In recent years, nonlinear manifold learning has shown its ability to automatically characterize molecular collective behavior. Unfortunately, these methods fail to provide a differentiable function mapping high-dimensional configurations to their low-dimensional representation, as required in enhanced sampling methods. We introduce a methodology that, starting from an ensemble representative of molecular flexibility, builds smooth and nonlinear data-driven collective variables (SandCV) from the output of nonlinear manifold learning algorithms. We demonstrate the method with a standard benchmark molecule, alanine dipeptide, and show how it can be non-intrusively combined with off-the-shelf enhanced sampling methods, here the adaptive biasing force method. We illustrate how enhanced sampling simulations with SandCV can explore regions that were poorly sampled in the original molecular ensemble. We further explore the transferability of SandCV from a simpler system, alanine dipeptide in vacuum, to a more complex system, alanine dipeptide in explicit water.

  17. Modeling and enhanced sampling of molecular systems with smooth and nonlinear data-driven collective variables

    NASA Astrophysics Data System (ADS)

    Hashemian, Behrooz; Millán, Daniel; Arroyo, Marino

    2013-12-01

    Collective variables (CVs) are low-dimensional representations of the state of a complex system, which help us rationalize molecular conformations and sample free energy landscapes with molecular dynamics simulations. Given their importance, there is need for systematic methods that effectively identify CVs for complex systems. In recent years, nonlinear manifold learning has shown its ability to automatically characterize molecular collective behavior. Unfortunately, these methods fail to provide a differentiable function mapping high-dimensional configurations to their low-dimensional representation, as required in enhanced sampling methods. We introduce a methodology that, starting from an ensemble representative of molecular flexibility, builds smooth and nonlinear data-driven collective variables (SandCV) from the output of nonlinear manifold learning algorithms. We demonstrate the method with a standard benchmark molecule, alanine dipeptide, and show how it can be non-intrusively combined with off-the-shelf enhanced sampling methods, here the adaptive biasing force method. We illustrate how enhanced sampling simulations with SandCV can explore regions that were poorly sampled in the original molecular ensemble. We further explore the transferability of SandCV from a simpler system, alanine dipeptide in vacuum, to a more complex system, alanine dipeptide in explicit water.

  18. Journal: A Review of Some Tracer-Test Design Equations for Tracer-Mass Estimation and Sample Collection Frequency

    EPA Science Inventory

    Determination of necessary tracer mass, initial sample-collection time, and subsequent sample-collection frequency are the three most difficult aspects to estimate for a proposed tracer test prior to conducting the tracer test. To facilitate tracer-mass estimation, 33 mass-estima...

  19. The Autism Simplex Collection: an international, expertly phenotyped autism sample for genetic and phenotypic analyses.

    PubMed

    Buxbaum, Joseph D; Bolshakova, Nadia; Brownfeld, Jessica M; Anney, Richard Jl; Bender, Patrick; Bernier, Raphael; Cook, Edwin H; Coon, Hilary; Cuccaro, Michael; Freitag, Christine M; Hallmayer, Joachim; Geschwind, Daniel; Klauck, Sabine M; Nurnberger, John I; Oliveira, Guiomar; Pinto, Dalila; Poustka, Fritz; Scherer, Stephen W; Shih, Andy; Sutcliffe, James S; Szatmari, Peter; Vicente, Astrid M; Vieland, Veronica; Gallagher, Louise

    2014-01-01

    There is an urgent need for expanding and enhancing autism spectrum disorder (ASD) samples, in order to better understand causes of ASD. In a unique public-private partnership, 13 sites with extensive experience in both the assessment and diagnosis of ASD embarked on an ambitious, 2-year program to collect samples for genetic and phenotypic research and begin analyses on these samples. The program was called The Autism Simplex Collection (TASC). TASC sample collection began in 2008 and was completed in 2010, and included nine sites from North America and four sites from Western Europe, as well as a centralized Data Coordinating Center. Over 1,700 trios are part of this collection, with DNA from transformed cells now available through the National Institute of Mental Health (NIMH). Autism Diagnostic Interview-Revised (ADI-R) and Autism Diagnostic Observation Schedule-Generic (ADOS-G) measures are available for all probands, as are standardized IQ measures, Vineland Adaptive Behavioral Scales (VABS), the Social Responsiveness Scale (SRS), Peabody Picture Vocabulary Test (PPVT), and physical measures (height, weight, and head circumference). At almost every site, additional phenotypic measures were collected, including the Broad Autism Phenotype Questionnaire (BAPQ) and Repetitive Behavior Scale-Revised (RBS-R), as well as the non-word repetition scale, Communication Checklist (Children's or Adult), and Aberrant Behavior Checklist (ABC). Moreover, for nearly 1,000 trios, the Autism Genome Project Consortium (AGP) has carried out Illumina 1 M SNP genotyping and called copy number variation (CNV) in the samples, with data being made available through the National Institutes of Health (NIH). Whole exome sequencing (WES) has been carried out in over 500 probands, together with ancestry matched controls, and this data is also available through the NIH. Additional WES is being carried out by the Autism Sequencing Consortium (ASC), where the focus is on sequencing complete

  20. The Autism Simplex Collection: an international, expertly phenotyped autism sample for genetic and phenotypic analyses

    PubMed Central

    2014-01-01

    Background There is an urgent need for expanding and enhancing autism spectrum disorder (ASD) samples, in order to better understand causes of ASD. Methods In a unique public-private partnership, 13 sites with extensive experience in both the assessment and diagnosis of ASD embarked on an ambitious, 2-year program to collect samples for genetic and phenotypic research and begin analyses on these samples. The program was called The Autism Simplex Collection (TASC). TASC sample collection began in 2008 and was completed in 2010, and included nine sites from North America and four sites from Western Europe, as well as a centralized Data Coordinating Center. Results Over 1,700 trios are part of this collection, with DNA from transformed cells now available through the National Institute of Mental Health (NIMH). Autism Diagnostic Interview-Revised (ADI-R) and Autism Diagnostic Observation Schedule-Generic (ADOS-G) measures are available for all probands, as are standardized IQ measures, Vineland Adaptive Behavioral Scales (VABS), the Social Responsiveness Scale (SRS), Peabody Picture Vocabulary Test (PPVT), and physical measures (height, weight, and head circumference). At almost every site, additional phenotypic measures were collected, including the Broad Autism Phenotype Questionnaire (BAPQ) and Repetitive Behavior Scale-Revised (RBS-R), as well as the non-word repetition scale, Communication Checklist (Children’s or Adult), and Aberrant Behavior Checklist (ABC). Moreover, for nearly 1,000 trios, the Autism Genome Project Consortium (AGP) has carried out Illumina 1 M SNP genotyping and called copy number variation (CNV) in the samples, with data being made available through the National Institutes of Health (NIH). Whole exome sequencing (WES) has been carried out in over 500 probands, together with ancestry matched controls, and this data is also available through the NIH. Additional WES is being carried out by the Autism Sequencing Consortium (ASC), where the

  1. Invention and validation of an automated camera system that uses optical character recognition to identify patient name mislabeled samples.

    PubMed

    Hawker, Charles D; McCarthy, William; Cleveland, David; Messinger, Bonnie L

    2014-03-01

    Mislabeled samples are a serious problem in most clinical laboratories. Published error rates range from 0.39/1000 to as high as 1.12%. Standardization of bar codes and label formats has not yet achieved the needed improvement. The mislabel rate in our laboratory, although low compared with published rates, prompted us to seek a solution to achieve zero errors. To reduce or eliminate our mislabeled samples, we invented an automated device using 4 cameras to photograph the outside of a sample tube. The system uses optical character recognition (OCR) to look for discrepancies between the patient name in our laboratory information system (LIS) vs the patient name on the customer label. All discrepancies detected by the system's software then require human inspection. The system was installed on our automated track and validated with production samples. We obtained 1 009 830 images during the validation period, and every image was reviewed. OCR passed approximately 75% of the samples, and no mislabeled samples were passed. The 25% failed by the system included 121 samples actually mislabeled by patient name and 148 samples with spelling discrepancies between the patient name on the customer label and the patient name in our LIS. Only 71 of the 121 mislabeled samples detected by OCR were found through our normal quality assurance process. We have invented an automated camera system that uses OCR technology to identify potential mislabeled samples. We have validated this system using samples transported on our automated track. Full implementation of this technology offers the possibility of zero mislabeled samples in the preanalytic stage.

  2. The Apollo Lunar Sample Image Collection: Digital Archiving and Online Access

    NASA Technical Reports Server (NTRS)

    Todd, Nancy S.; Lofgren, Gary E.; Stefanov, William L.; Garcia, Patricia A.

    2014-01-01

    The primary goal of the Apollo Program was to land human beings on the Moon and bring them safely back to Earth. This goal was achieved during six missions - Apollo 11, 12, 14, 15, 16, and 17 - that took place between 1969 and 1972. Among the many noteworthy engineering and scientific accomplishments of these missions, perhaps the most important in terms of scientific impact was the return of 382 kg (842 lb.) of lunar rocks, core samples, pebbles, sand, and dust from the lunar surface to Earth. Returned samples were curated at JSC (then known as the Manned Spacecraft Center) and, as part of the original processing, high-quality photographs were taken of each sample. The top, bottom, and sides of each rock sample were photographed, along with 16 stereo image pairs taken at 45-degree intervals. Photographs were also taken whenever a sample was subdivided and when thin sections were made. This collection of lunar sample images consists of roughly 36,000 photographs; all six Apollo missions are represented.

  3. January 2012 Groundwater Sampling at the Gnome-Coach, New Mexico, Site (Data Validation Package)

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Findlay, Richard C.

    2012-12-01

    Annual sampling was conducted January 18, 2012, to monitor groundwater for potential radionuclide contamination at the Gnome-Coach site in New Mexico. The sampling was performed as specified in the Sampling and Analysis Plan for U.S. Department of Energy Office of Legacy Management Sites (LMS/PLN/S04351, continually updated). Well LRL-7 was not sampled per instruction from the lead. A duplicate sample was collected from well USGS-1 and water levels were measured in the monitoring wells onsite.

  4. January 2011 Groundwater Sampling at the Gnome-Coach, New Mexico, Site (Data Validation Package)

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Findlay, Richard C.

    2011-11-01

    Annual sampling was conducted January 19, 2011, to monitor groundwater for potential radionuclide contamination at the Gnome-Coach site in New Mexico. The sampling was performed as specified in the Sampling and Analysis Plan for U.S. Department of Energy Office of Legacy Management Sites (LMS/PLN/S04351, continually updated). Well LRL-7 was not sampled per instruction from the lead. A duplicate sample was collected from well USGS-1.Water levels were measured in the monitoring wells onsite.

  5. Validation Study of a Gatekeeping Attitude Index for Social Work Education

    ERIC Educational Resources Information Center

    Tam, Dora M. Y.; Coleman, Heather

    2011-01-01

    This article reports on a study designed to validate the Gatekeeping Attitude Index, a 14-item Likert scaling index. The authors collected data from a convenience sample of social work field instructors (N = 188) with a response rate of 74.0%. Construct validation by exploratory factor analysis identified a 2-factor solution on the index after…

  6. Planning Considerations Related to Collecting and Analyzing Samples of the Martian Soils

    NASA Technical Reports Server (NTRS)

    Liu, Yang; Mellon, Mike T.; Ming, Douglas W.; Morris, Richard V.; Noble, Sarah K.; Sullivan, Robert J.; Taylor, Lawrence A.; Beaty, David W.

    2014-01-01

    The Mars Sample Return (MSR) End-to-End International Science Analysis Group (E2E-iSAG [1]) established scientific objectives associ-ated with Mars returned-sample science that require the return and investigation of one or more soil samples. Soil is defined here as loose, unconsolidated materials with no implication for the presence or absence of or-ganic components. The proposed Mars 2020 (M-2020) rover is likely to collect and cache soil in addition to rock samples [2], which could be followed by future sample retrieval and return missions. Here we discuss key scientific consid-erations for sampling and caching soil samples on the proposed M-2020 rover, as well as the state in which samples would need to be preserved when received by analysts on Earth. We are seeking feedback on these draft plans as input to mission requirement formulation. A related planning exercise on rocks is reported in an accompanying abstract [3].

  7. A multisite validation of whole slide imaging for primary diagnosis using standardized data collection and analysis.

    PubMed

    Wack, Katy; Drogowski, Laura; Treloar, Murray; Evans, Andrew; Ho, Jonhan; Parwani, Anil; Montalto, Michael C

    2016-01-01

    Text-based reporting and manual arbitration for whole slide imaging (WSI) validation studies are labor intensive and do not allow for consistent, scalable, and repeatable data collection or analysis. The objective of this study was to establish a method of data capture and analysis using standardized codified checklists and predetermined synoptic discordance tables and to use these methods in a pilot multisite validation study. Fifteen case report form checklists were generated from the College of American Pathology cancer protocols. Prior to data collection, all hypothetical pairwise comparisons were generated, and a level of harm was determined for each possible discordance. Four sites with four pathologists each generated 264 independent reads of 33 cases. Preestablished discordance tables were applied to determine site by site and pooled accuracy, intrareader/intramodality, and interreader intramodality error rates. Over 10,000 hypothetical pairwise comparisons were evaluated and assigned harm in discordance tables. The average difference in error rates between WSI and glass, as compared to ground truth, was 0.75% with a lower bound of 3.23% (95% confidence interval). Major discordances occurred on challenging cases, regardless of modality. The average inter-reader agreement across sites for glass was 76.5% (weighted kappa of 0.68) and for digital it was 79.1% (weighted kappa of 0.72). These results demonstrate the feasibility and utility of employing standardized synoptic checklists and predetermined discordance tables to gather consistent, comprehensive diagnostic data for WSI validation studies. This method of data capture and analysis can be applied in large-scale multisite WSI validations.

  8. [Health agents' perspective on the incorporation of self-collected samples in HPV screening programs].

    PubMed

    Curotto, Mariana; Barletta, Paula; Paolino, Melisa; Arrossi, Silvina

    2017-06-01

    The objective of this study was to analyze health agents' perception of self-collecting of samples for HPV testing among women and the degree of agreement by the agents to incorporate this approach into their daily tasks. A self-administered questionnaire was applied to 127/191 health agents that participated in the EMA Project (Proyecto Evaluación Modalidad Autotoma) in the province of Jujuy, Argentina, in 2012-2013. The health agents with and without the experience of offering self-collected sampling expressed a high degree of agreement towards adoption of the strategy (78.7%), given its potential to prevent cervical cancer and its contribution to health care for the women under their coverage. However, the health agents identified the extra work and problems linking to the formal health system as the main barriers to offering this modality in the future. The study found that self-collecting of samples is a practice that can be adopted by health agents in the province of Jujuy, but that it should be accompanied by support measures from the formal health system.

  9. Use of Body-Mounted Cameras to Enhance Data Collection: An Evaluation of Two Arthropod Sampling Techniques.

    PubMed

    Hagler, James R; Thompson, Alison L; Stefanek, Melissa A; Machtley, Scott A

    2018-03-01

    A study was conducted that compared the effectiveness of a sweepnet versus a vacuum suction device for collecting arthropods in cotton. The study differs from previous research in that body-mounted action cameras (B-MACs) were used to record the activity of the person conducting the arthropod collections. The videos produced by the B-MACs were then analyzed with behavioral event recording software to quantify various aspects of the sampling process. The sampler's speed and the number of sampling sweeps or vacuum suctions taken over a fixed distance (12.2 m) of cotton were two of the more significant sampling characteristics quantified for each method. The arthropod counts obtained, combined with the analyses of the videos, enabled us to estimate arthropod sampling efficiency for each technique based on fixed distance, time, and sample unit measurements. Data revealed that the vacuuming was the most precise method for collecting arthropods in the relatively small cotton research plots. However, data also indicates that the sweepnet method would be more efficient for collecting most of the cotton-dwelling arthropod taxa, especially if the sampler could continuously sweep for at least 1 min or ≥80 m (e.g., in larger research plots). The B-MACs are inexpensive and non-cumbersome, the video images generated are outstanding, and they can be archived to provide permanent documentation of a research project. The methods described here could be useful for other types of field-based research to enhance data collection efficiency.

  10. COLLECTING URINE SAMPLES FROM YOUNG CHILDREN USING COTTON GAUZE FOR PESTICIDE STUDIES

    EPA Science Inventory

    To estimate pesticide exposure, urine samples are often needed to analyze pesticide metabolites. However, this is difficult for children wearing diapers because simple and feasible techniques suitable for field collection are not available. The objectives of this study were to t...

  11. PIXE Analysis of Atmospheric Aerosol Samples Collected in the Adirondack Mountains

    NASA Astrophysics Data System (ADS)

    Yoskowitz, Josh; Ali, Salina; Nadareski, Benjamin; Safiq, Alexandrea; Smith, Jeremy; Labrake, Scott; Vineyard, Michael

    2013-10-01

    We have performed an elemental analysis of atmospheric aerosol samples collected at Piseco Lake in Upstate New York using proton induced x-ray emission spectroscopy (PIXE). This work is part of a systematic study of airborne pollution in the Adirondack Mountains. Of particular interest is the sulfur content that can contribute to acid rain, a well-documented problem in the Adirondacks. We used a nine-stage cascade impactor to collect the samples and distribute the particulate matter onto Kapton foils by particle size. The PIXE experiments were performed with 2.2-MeV proton beams from the 1.1-MV pelletron accelerator in the Union College Ion-Beam Analysis Laboratory. X-Ray energy spectra were measured with a silicon drift detector and analyzed with GUPIX software to determine the elemental concentrations of the aerosols. A broad range of elements from silicon to zinc were detected with significant sulfur concentrations measured for particulate matter between 0.25 and 0.5 μm in size. The PIXE analysis will be described and preliminary results will be presented.

  12. A disposable sampling device to collect volume-measured DBS directly from a fingerprick onto DBS paper.

    PubMed

    Lenk, Gabriel; Sandkvist, Sören; Pohanka, Anton; Stemme, Göran; Beck, Olof; Roxhed, Niclas

    2015-01-01

    DBS samples collected from a fingerprick typically vary in volume and homogeneity and hence make an accurate quantitative analysis of DBS samples difficult. We report a prototype which first defines a precise liquid volume and subsequently stores it to a conventional DBS matrix. Liquid volumes of 2.2 µl ± 7.1% (n = 21) for deionized water and 6.1 µl ± 8.8% (n = 15) for whole blood have been successfully metered and stored in DBS paper. The new method of collecting a defined volume of blood by DBS sampling has the potential to reduce assay bias for the quantitative evaluation of DBS samples while maintaining the simplicity of conventional DBS sampling.

  13. Construct validation of emotional labor scale for a sample of Pakistani corporate employees.

    PubMed

    Akhter, Noreen

    2017-02-01

    To translate, adapt and validate emotional labour scale for Pakistani corporate employees. This study was conducted in locale of Rawalpindi and Islamabad from October 2014 to December 2015, and comprised customer service employees of commercial banks and telecommunication companies. It comprised of two independent parts. Part one had two steps. Step one involved translation and adaptation of the instrument. In the second step psychometric properties of the translated scale were established by administering it to customer services employees from commercial banks and the telecommunication sector. Data of the pilot study was analysed by using exploratory factor analysis to extract the initial factor of emotional labour. Part two comprised the main study. Commercial bank employees were included in the sample by using convenient sampling technique. SPSS 20 was used for data analysis. There were 145 participants in the first study and 495 in the second study . Exploratory factor analysis initially generated three-factor model of emotional labour which was further confirmed by confirmatory factor analysis suggesting that emotional labour had three distinct dimensions, i.e. surface acting, deep acting and genuine expressions of emotions. The emotional labour scale was found to be a valid and reliable measure.

  14. Series: Practical guidance to qualitative research. Part 3: Sampling, data collection and analysis.

    PubMed

    Moser, Albine; Korstjens, Irene

    2018-12-01

    In the course of our supervisory work over the years, we have noticed that qualitative research tends to evoke a lot of questions and worries, so-called frequently asked questions (FAQs). This series of four articles intends to provide novice researchers with practical guidance for conducting high-quality qualitative research in primary care. By 'novice' we mean Master's students and junior researchers, as well as experienced quantitative researchers who are engaging in qualitative research for the first time. This series addresses their questions and provides researchers, readers, reviewers and editors with references to criteria and tools for judging the quality of qualitative research papers. The second article focused on context, research questions and designs, and referred to publications for further reading. This third article addresses FAQs about sampling, data collection and analysis. The data collection plan needs to be broadly defined and open at first, and become flexible during data collection. Sampling strategies should be chosen in such a way that they yield rich information and are consistent with the methodological approach used. Data saturation determines sample size and will be different for each study. The most commonly used data collection methods are participant observation, face-to-face in-depth interviews and focus group discussions. Analyses in ethnographic, phenomenological, grounded theory, and content analysis studies yield different narrative findings: a detailed description of a culture, the essence of the lived experience, a theory, and a descriptive summary, respectively. The fourth and final article will focus on trustworthiness and publishing qualitative research.

  15. Series: Practical guidance to qualitative research. Part 3: Sampling, data collection and analysis

    PubMed Central

    Moser, Albine; Korstjens, Irene

    2018-01-01

    Abstract In the course of our supervisory work over the years, we have noticed that qualitative research tends to evoke a lot of questions and worries, so-called frequently asked questions (FAQs). This series of four articles intends to provide novice researchers with practical guidance for conducting high-quality qualitative research in primary care. By ‘novice’ we mean Master’s students and junior researchers, as well as experienced quantitative researchers who are engaging in qualitative research for the first time. This series addresses their questions and provides researchers, readers, reviewers and editors with references to criteria and tools for judging the quality of qualitative research papers. The second article focused on context, research questions and designs, and referred to publications for further reading. This third article addresses FAQs about sampling, data collection and analysis. The data collection plan needs to be broadly defined and open at first, and become flexible during data collection. Sampling strategies should be chosen in such a way that they yield rich information and are consistent with the methodological approach used. Data saturation determines sample size and will be different for each study. The most commonly used data collection methods are participant observation, face-to-face in-depth interviews and focus group discussions. Analyses in ethnographic, phenomenological, grounded theory, and content analysis studies yield different narrative findings: a detailed description of a culture, the essence of the lived experience, a theory, and a descriptive summary, respectively. The fourth and final article will focus on trustworthiness and publishing qualitative research. PMID:29199486

  16. Validity and Reliability of the Turkish Chronic Pain Acceptance Questionnaire

    PubMed Central

    Akmaz, Hazel Ekin; Uyar, Meltem; Kuzeyli Yıldırım, Yasemin; Akın Korhan, Esra

    2018-01-01

    Background: Pain acceptance is the process of giving up the struggle with pain and learning to live a worthwhile life despite it. In assessing patients with chronic pain in Turkey, making a diagnosis and tracking the effectiveness of treatment is done with scales that have been translated into Turkish. However, there is as yet no valid and reliable scale in Turkish to assess the acceptance of pain. Aims: To validate a Turkish version of the Chronic Pain Acceptance Questionnaire developed by McCracken and colleagues. Study Design: Methodological and cross sectional study. Methods: A simple randomized sampling method was used in selecting the study sample. The sample was composed of 201 patients, more than 10 times the number of items examined for validity and reliability in the study, which totaled 20. A patient identification form, the Chronic Pain Acceptance Questionnaire, and the Brief Pain Inventory were used to collect data. Data were collected by face-to-face interviews. In the validity testing, the content validity index was used to evaluate linguistic equivalence, content validity, construct validity, and expert views. In reliability testing of the scale, Cronbach’s α coefficient was calculated, and item analysis and split-test reliability methods were used. Principal component analysis and varimax rotation were used in factor analysis and to examine factor structure for construct concept validity. Results: The item analysis established that the scale, all items, and item-total correlations were satisfactory. The mean total score of the scale was 21.78. The internal consistency coefficient was 0.94, and the correlation between the two halves of the scale was 0.89. Conclusion: The Chronic Pain Acceptance Questionnaire, which is intended to be used in Turkey upon confirmation of its validity and reliability, is an evaluation instrument with sufficient validity and reliability, and it can be reliably used to examine patients’ acceptance of chronic pain

  17. Profiling quinones in ambient air samples collected from the Athabasca region (Canada).

    PubMed

    Wnorowski, Andrzej; Charland, Jean-Pierre

    2017-12-01

    This paper presents new findings on polycyclic aromatic hydrocarbon oxidation products-quinones that were collected in ambient air samples in the proximity of oil sands exploration. Quinones were characterized for their diurnal concentration variability, phase partitioning, and molecular size distribution. Gas-phase (GP) and particle-phase (PM) ambient air samples were collected separately in the summer; a lower quinone content was observed in the PM samples from continuous 24-h sampling than from combined 12-h sampling (day and night). The daytime/nocturnal samples demonstrated that nighttime conditions led to lower concentrations and some quinones not being detected. The highest quinone levels were associated with wind directions originating from oil sands exploration sites. The statistical correlation with primary pollutants directly emitted from oil sands industrial activities indicated that the bulk of the detected quinones did not originate directly from primary emission sources and that quinone formation paralleled a reduction in primary source NO x levels. This suggests a secondary chemical transformation of primary pollutants as the origin of the determined quinones. Measurements of 19 quinones included five that have not previously been reported in ambient air or in Standard Reference Material 1649a/1649b and seven that have not been previously measured in ambient air in the underivatized form. This is the first paper to report on quinone characterization in secondary organic aerosols originating from oil sands activities, to distinguish chrysenequinone and anthraquinone positional isomers in ambient air, and to report the requirement of daylight conditions for benzo[a]pyrenequinone and naphthacenequinone to be present in ambient air. Crown Copyright © 2017. Published by Elsevier Ltd. All rights reserved.

  18. Data Validation Package: April 2016 Groundwater Sampling at the Falls City, Texas, Disposal Site

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Jasso, Tashina; Widdop, Michael

    Nine groundwater samples were collected at the Falls City, Texas, Disposal Site as specified in the March 2008 Long-Term Surveillance Plan for the US Department of Energy Falls City Uranium Mill Tailings Disposal Site, Falls City, Texas (DOE-LM/1602-2008). Sampling and analyses were conducted as specified in the Sampling and Analysis Plan for US Department of Energy Office of Legacy Management Sites (LMS/PRO/S04351, continually updated). The wells sampled included the cell performance monitoring wells (0709, 0858, 0880, 0906, and 0921) and the groundwater monitoring wells (0862, 0886, 0891, 0924, and 0963). A duplicate sample was collected from location 0891. Water levelsmore » were measured at each sampled well. Historically, cell performance monitoring wells 0908 and 0916 have not produced water and were confirmed as dry during this sampling event. These wells are completed above the saturated interval in the formation. Notable observations for time-concentration graphs in this report include: (1) uranium concentrations in well 0891 continue to increase; (2) the uranium concentration in well 0880 is higher than the 2015 value and lower than the 2014 value, and it remains within the range of historical values; and (3) uranium concentrations in the other sampled wells are below 2 mg/L and consistent with previous results.« less

  19. 78 FR 70577 - Agency Information Collection Activities; Proposed Collection, Comments Requested, New Collection...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-11-26

    ... Program the ability to conduct pretests which evaluate the validity and reliability of information... the proposed collection of information, including the validity of the methodology and assumptions used...

  20. Extracting samples of high diversity from thematic collections of large gene banks using a genetic-distance based approach

    PubMed Central

    2010-01-01

    Background Breeding programs are usually reluctant to evaluate and use germplasm accessions other than the elite materials belonging to their advanced populations. The concept of core collections has been proposed to facilitate the access of potential users to samples of small sizes, representative of the genetic variability contained within the gene pool of a specific crop. The eventual large size of a core collection perpetuates the problem it was originally proposed to solve. The present study suggests that, in addition to the classic core collection concept, thematic core collections should be also developed for a specific crop, composed of a limited number of accessions, with a manageable size. Results The thematic core collection obtained meets the minimum requirements for a core sample - maintenance of at least 80% of the allelic richness of the thematic collection, with, approximately, 15% of its size. The method was compared with other methodologies based on the M strategy, and also with a core collection generated by random sampling. Higher proportions of retained alleles (in a core collection of equal size) or similar proportions of retained alleles (in a core collection of smaller size) were detected in the two methods based on the M strategy compared to the proposed methodology. Core sub-collections constructed by different methods were compared regarding the increase or maintenance of phenotypic diversity. No change on phenotypic diversity was detected by measuring the trait "Weight of 100 Seeds", for the tested sampling methods. Effects on linkage disequilibrium between unlinked microsatellite loci, due to sampling, are discussed. Conclusions Building of a thematic core collection was here defined by prior selection of accessions which are diverse for the trait of interest, and then by pairwise genetic distances, estimated by DNA polymorphism analysis at molecular marker loci. The resulting thematic core collection potentially reflects the maximum

  1. Reliability and Validity of the Spanish Adaptation of EOSS, Comparing Normal and Clinical Samples

    ERIC Educational Resources Information Center

    Valero-Aguayo, Luis; Ferro-Garcia, Rafael; Lopez-Bermudez, Miguel Angel; de Huralde, Ma. Angeles Selva-Lopez

    2012-01-01

    The Experiencing of Self Scale (EOSS) was created for the evaluation of Functional Analytic Psychotherapy (Kohlenberg & Tsai, 1991, 2001, 2008) in relation to the concept of the experience of personal self as socially and verbally constructed. This paper presents a reliability and validity study of the EOSS with a Spanish sample (582…

  2. Cleaning the IceMole: collection of englacial samples from Blood Falls, Antarctica

    NASA Astrophysics Data System (ADS)

    Mikucki, J.; Digel, I.; Chua, M.; Davis, J.; Ghosh, D.; Lyons, W. B.; Welch, K. A.; Purcell, A.; Francke, G.; Feldmann, M.; Espe, C.; Heinen, D.; Dachwald, B.; Kowalski, J.; Tulaczyk, S. M.

    2016-12-01

    The Minimally Invasive Direct Glacial Access project (MIDGE) used a maneuverable thermoelectric melting probe called the IceMole to collect the first englacial samples of brine from Blood Falls, Antarctica. In order to maintain the scientific integrity of samples collected and minimize impact to this specially protected ecosystem, microbial and chemical contamination of the IceMole needed to be minimized. Guidelines have been established for research in Antarctic subglacial systems by the scientific and regulatory community and have been detailed by the "Code of Conduct for the Exploration and Research of Subglacial Aquatic Environments" put forth by the Scientific Committee on Antarctic Research (SCAR) Action Group, and was submitted to the Antarctic Treaty System. This Code of Conduct (CoC) recognizes the ecological importance and pristine nature of subglacial habitats and recommends a path forward towards clean exploration. Similarly, the US and European space agencies (NASA and ESA) have detailed instrument preparation protocols for the exploration of icy worlds in our solar system for planetary protection. Given the synergistic aims of these two groups we have adopted protocols from both subglacial and space exploration approaches. Here we present our approach to cleaning the IceMole in the field and report on ability to reduce the bioload inherent on the melter. Specifically our protocol reduced the exterior bio-load by an order of magnitude, to levels common in most clean rooms, and 1-3 orders of magnitude below that of Taylor Glacier ice surrounding Blood Falls. Our results indicate that the collection of englacial samples for microbiological analysis is feasible with melting probes.

  3. Mars sample collection and preservation

    NASA Technical Reports Server (NTRS)

    Blanchard, Douglas P.

    1988-01-01

    The intensive exploration of Mars is a major step in the systematic exploration of the solar system. Mars, earth, and Venus provide valuable contrasts in planetary evolution. Mars exploration has progressed through the stages of exploration and is now ready for a sample-return mission. About 5 kg of intelligently selected samples will be returned from Mars. A variety of samples are wanted. This requires accurate landing in areas of high interest, surface mobility and analytical capability, a variety of sampling tools, and stringent preservation and isolation measures.

  4. Validation of the MOS Social Support Survey 6-item (MOS-SSS-6) measure with two large population-based samples of Australian women.

    PubMed

    Holden, Libby; Lee, Christina; Hockey, Richard; Ware, Robert S; Dobson, Annette J

    2014-12-01

    This study aimed to validate a 6-item 1-factor global measure of social support developed from the Medical Outcomes Study Social Support Survey (MOS-SSS) for use in large epidemiological studies. Data were obtained from two large population-based samples of participants in the Australian Longitudinal Study on Women's Health. The two cohorts were aged 53-58 and 28-33 years at data collection (N = 10,616 and 8,977, respectively). Items selected for the 6-item 1-factor measure were derived from the factor structure obtained from unpublished work using an earlier wave of data from one of these cohorts. Descriptive statistics, including polychoric correlations, were used to describe the abbreviated scale. Cronbach's alpha was used to assess internal consistency and confirmatory factor analysis to assess scale validity. Concurrent validity was assessed using correlations between the new 6-item version and established 19-item version, and other concurrent variables. In both cohorts, the new 6-item 1-factor measure showed strong internal consistency and scale reliability. It had excellent goodness-of-fit indices, similar to those of the established 19-item measure. Both versions correlated similarly with concurrent measures. The 6-item 1-factor MOS-SSS measures global functional social support with fewer items than the established 19-item measure.

  5. Comparison of indoor air sampling and dust collection methods for fungal exposure assessment using quantitative PCR.

    PubMed

    Cox, Jennie; Indugula, Reshmi; Vesper, Stephen; Zhu, Zheng; Jandarov, Roman; Reponen, Tiina

    2017-10-18

    Evaluating fungal contamination indoors is complicated because of the many different sampling methods utilized. In this study, fungal contamination was evaluated using five sampling methods and four matrices for results. The five sampling methods were a 48 hour indoor air sample collected with a Button™ inhalable aerosol sampler and four types of dust samples: a vacuumed floor dust sample, newly settled dust collected for four weeks onto two types of electrostatic dust cloths (EDCs) in trays, and a wipe sample of dust from above floor surfaces. The samples were obtained in the bedrooms of asthmatic children (n = 14). Quantitative polymerase chain reaction (qPCR) was used to analyze the dust and air samples for the 36 fungal species that make up the Environmental Relative Moldiness Index (ERMI). The results from the samples were compared by four matrices: total concentration of fungal cells, concentration of fungal species associated with indoor environments, concentration of fungal species associated with outdoor environments, and ERMI values (or ERMI-like values for air samples). The ERMI values for the dust samples and the ERMI-like values for the 48 hour air samples were not significantly different. The total cell concentrations of the 36 species obtained with the four dust collection methods correlated significantly (r = 0.64-0.79, p < 0.05), with the exception of the vacuumed floor dust and newly settled dust. In addition, fungal cell concentrations of indoor associated species correlated well between all four dust sampling methods (r = 0.68-0.86, p < 0.01). No correlation was found between the fungal concentrations in the air and dust samples primarily because of differences in concentrations of Cladosporium cladosporioides Type 1 and Epicoccum nigrum. A representative type of dust sample and a 48 hour air sample might both provide useful information about fungal exposures.

  6. Astronaut Charles Duke photographed collecting lunar samples at Station 1

    NASA Technical Reports Server (NTRS)

    1972-01-01

    Astronaut Charles M. Duke Jr., lunar module pilot of the Apollo 16 lunar landing mission, is photographed collecting lunar samples at Station no. 1 during the first Apollo 16 extravehicular activity at the Descartes landing site. This picture, looking eastward, was taken by Astronaut John W. Young, commander. Duke is standing at the rim of Plum crater, which is 40 meters in diameter and 10 meters deep. The parked Lunar Roving Vehicle can be seen in the left background.

  7. Automation and validation of DNA-banking systems.

    PubMed

    Thornton, Melissa; Gladwin, Amanda; Payne, Robin; Moore, Rachael; Cresswell, Carl; McKechnie, Douglas; Kelly, Steve; March, Ruth

    2005-10-15

    DNA banking is one of the central capabilities on which modern genetic research rests. The DNA-banking system plays an essential role in the flow of genetic data from patients and genetics researchers to the application of genetic research in the clinic. Until relatively recently, large collections of DNA samples were not common in human genetics. Now, collections of hundreds of thousands of samples are common in academic institutions and private companies. Automation of DNA banking can dramatically increase throughput, eliminate manual errors and improve the productivity of genetics research. An increased emphasis on pharmacogenetics and personalized medicine has highlighted the need for genetics laboratories to operate within the principles of a recognized quality system such as good laboratory practice (GLP). Automated systems are suitable for such laboratories but require a level of validation that might be unfamiliar to many genetics researchers. In this article, we use the AstraZeneca automated DNA archive and reformatting system (DART) as a case study of how such a system can be successfully developed and validated within the principles of GLP.

  8. 40 CFR 761.283 - Determination of the number of samples to collect and sample collection locations.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... sampling points after the recleaning, but select three new pairs of sampling coordinates. (i) Beginning in the southwest corner (lower left when facing magnetic north) of the area to be sampled, measure in... new pair of sampling coordinates. Continue to select pairs of sampling coordinates until three are...

  9. Convergent Validity of the Early Memory Index in Two Primary Care Samples.

    PubMed

    Porcerelli, John H; Cogan, Rosemary; Melchior, Katherine A; Jasinski, Matthew J; Richardson, Laura; Fowler, Shannon; Morris, Pierre; Murdoch, William

    2016-01-01

    Karliner, Westrich, Shedler, and Mayman (1996) developed the Early Memory Index (EMI) to assess mental health, narrative coherence, and traumatic experiences in reports of early memories. We assessed the convergent validity of EMI scales with data from 103 women from an urban primary care clinic (Study 1) and data from 48 women and 24 men from a suburban primary care clinic (Study 2). Patients provided early memory narratives and completed self-report measures of psychopathology, trauma, and health care utilization. In both studies, lower scores on the Mental Health scale and higher scores on the Traumatic Experiences scale were related to higher scores on measures of psychopathology and childhood trauma. Less consistent associations were found between the Mental Health and Traumatic Experiences scores and measures of health care utilization. The Narrative Coherence scale showed inconsistent relationships across measures in both samples. In analyses assessing the overall fit between hypothesized and actual correlations between EMI scores and measures of psychopathology, severity of trauma symptoms, and health care utilization, the Mental Health scale of the EMI demonstrated stronger convergent validity than the EMI Traumatic Experiences scale. The results provide support for the convergent validity of the Mental Health scale of the EMI.

  10. An integrated bioanalytical method development and validation approach: case studies.

    PubMed

    Xue, Y-J; Melo, Brian; Vallejo, Martha; Zhao, Yuwen; Tang, Lina; Chen, Yuan-Shek; Keller, Karin M

    2012-10-01

    We proposed an integrated bioanalytical method development and validation approach: (1) method screening based on analyte's physicochemical properties and metabolism information to determine the most appropriate extraction/analysis conditions; (2) preliminary stability evaluation using both quality control and incurred samples to establish sample collection, storage and processing conditions; (3) mock validation to examine method accuracy and precision and incurred sample reproducibility; and (4) method validation to confirm the results obtained during method development. This integrated approach was applied to the determination of compound I in rat plasma and compound II in rat and dog plasma. The effectiveness of the approach was demonstrated by the superior quality of three method validations: (1) a zero run failure rate; (2) >93% of quality control results within 10% of nominal values; and (3) 99% incurred sample within 9.2% of the original values. In addition, rat and dog plasma methods for compound II were successfully applied to analyze more than 900 plasma samples obtained from Investigational New Drug (IND) toxicology studies in rats and dogs with near perfect results: (1) a zero run failure rate; (2) excellent accuracy and precision for standards and quality controls; and (3) 98% incurred samples within 15% of the original values. Copyright © 2011 John Wiley & Sons, Ltd.

  11. Astronauts Young and Duke collect rock samples along simulated lunar traverse

    NASA Technical Reports Server (NTRS)

    1971-01-01

    Astronauts John W. Young, left, prime crew commander for Apollo 16, and Charles M. Duke Jr., lunar module pilot, collect rock samples along a simulated lunar traverse route in the Coso Hills, near Ridgecrest, California. Astronaut Eugene A. Cernan, right background, prime crew commander for Apollo 17, looks on. The astronauts trained at the U.S. Naval Ordnance Test Station.

  12. Blood collection tubes as medical devices: The potential to affect assays and proposed verification and validation processes for the clinical laboratory.

    PubMed

    Bowen, Raffick A R; Adcock, Dorothy M

    2016-12-01

    Blood collection tubes (BCTs) are an often under-recognized variable in the preanalytical phase of clinical laboratory testing. Unfortunately, even the best-designed and manufactured BCTs may not work well in all clinical settings. Clinical laboratories, in collaboration with healthcare providers, should carefully evaluate BCTs prior to putting them into clinical use to determine their limitations and ensure that patients are not placed at risk because of inaccuracies due to poor tube performance. Selection of the best BCTs can be achieved through comparing advertising materials, reviewing the literature, observing the device at a scientific meeting, receiving a demonstration, evaluating the device under simulated conditions, or testing the device with patient samples. Although many publications have discussed method validations, few detail how to perform experiments for tube verification and validation. This article highlights the most common and impactful variables related to BCTs and discusses the validation studies that a typical clinical laboratory should perform when selecting BCTs. We also present a brief review of how in vitro diagnostic devices, particularly BCTs, are regulated in the United States, the European Union, and Canada. The verification and validation of BCTs will help to avoid the economic and human costs associated with incorrect test results, including poor patient care, unnecessary testing, and delays in test results. We urge laboratorians, tube manufacturers, diagnostic companies, and other researchers to take all the necessary steps to protect against the adverse effects of BCT components and their additives on clinical assays. Copyright © 2016 The Canadian Society of Clinical Chemists. Published by Elsevier Inc. All rights reserved.

  13. Validation of the Beck Depression Inventory-II in a Low-Income African American Sample of Medical Outpatients

    ERIC Educational Resources Information Center

    Grothe, Karen B.; Dutton, Gareth R.; Jones, Glenn N.; Bodenlos, Jamie; Ancona, Martin; Brantley, Phillip J.

    2005-01-01

    The psychometric properties of the Beck Depression Inventory-II (BDI-II) are well established with primarily Caucasian samples. However, little is known about its reliability and validity with minority groups. This study evaluated the psychometric properties of the BDI-II in a sample of low-income African American medical outpatients (N = 220).…

  14. Astrobiological relevance and feasibility of a sample collection mission to the atmosphere of Venus

    NASA Astrophysics Data System (ADS)

    Schulze-Makuch, Dirk; Irwin, Louis N.; Irwin, Troy

    2002-11-01

    The lower cloud level of the Venusian atmosphere is an environmental niche that could harbor microbial life. Particularly the mode 3 particles that are enriched in this atmospheric layer are of astrobiological interest. We propose here a sample collection mission to the atmosphere of Venus and evaluate three mission options. The first option is a Stardust-type spacecraft used for sample collection, the second option is a Rotating Probe Tether System, and the third option is a Parachute Drop - Balloon Floatation System. Given the current state of technology, the result of our preliminary analysis is that the Parachute Drop - Balloon Floatation Mission is the most feasible and practical option.

  15. CTEPP STANDARD OPERATING PROCEDURE FOR COLLECTION OF FLOOR DUST SAMPLES FOR PERSISTENT ORGANIC POLLUTANTS (SOP-2.19)

    EPA Science Inventory

    This SOP describes the method for collecting a floor dust sample from carpet. Dust samples will be collected in the room that the child uses most at home and/or at day care using a High Volume Small Surface Sampler (HVS3). In addition, participants will also be asked to donate a ...

  16. A Prototype Ice-Melting Probe for Collecting Biological Samples from Cryogenic Ice at Low Pressure

    NASA Astrophysics Data System (ADS)

    Davis, Ashley

    2017-08-01

    In the Solar System, the surface of an icy moon is composed of irregular ice formations at cryogenic temperatures (<200 K), with an oxidized surface layer and a tenuous atmosphere at very low pressure (<10-6 atm). A lander mission, whose aim is to collect and analyze biological samples from the surface ice, must contain a device that collects samples without refreezing liquid and without sublimation of ice. In addition, if the samples are biological in nature, then precautions must be taken to ensure the samples do not overheat or mix with the oxidized layer. To achieve these conditions, the collector must maintain temperatures close to maintenance or growth conditions of the organism (<293 K), and it must separate or neutralize the oxidized layer and be physically gentle. Here, we describe a device that addresses these requirements and is compatible with low atmospheric pressure while using no pumps. The device contains a heated conical probe with a central orifice, which is forced into surface ice and directs the meltwater upward into a reservoir. The force on the probe is proportional to the height of meltwater (pressure) obtained in the system and allows regulation of the melt rate and temperature of the sample. The device can collect 5-50 mL of meltwater from the surface of an ice block at 233-208 K with an environmental pressure of less than 10-2 atm while maintaining a sample temperature between 273 and 293 K. These conditions maintain most biological samples in a pristine state and maintain the integrity of most organisms' structure and function.

  17. Validity of the MMPI-2-RF (restructured form) L-r and K-r scales in detecting underreporting in clinical and nonclinical samples.

    PubMed

    Sellbom, Martin; Bagby, R Michael

    2008-12-01

    In the current investigation, the authors examined the validity of the L-r and K-r scales on the recently developed Minnesota Multiphasic Personality Inventory-2-Restructured Form (MMPI-2-RF; Y. S. Ben-Porath & A. Tellegen, in press) in measuring underreported response bias. Three archival samples previously collected for examining MMPI-2 validity scales were reanalyzed in 2 studies. In Study 1 L-r and K-r significantly differentiated 2 groups of participants (patients with schizophrenia and university students) who had been instructed to underreport on the MMPI-2 from participants who took the test under standard instructions. L-r and K-r also added incremental predictive variance to one another in differentiating these groups. In Study 2 a similar set of outcomes emerged through the use of a differential prevalence design in which L-r and K-r significantly differentiated a group of child custody litigants who were administered the MMPI-2 from university students taking the test under standard instructions. (c) 2008 APA, all rights reserved.

  18. Validation of a polymerase chain reaction aided transcript titration assay (PATTY) for topoisomerase II in lung cancer samples.

    PubMed

    Dingemans, A M; Van Ark-Otte, J; Smit, E F; Postmus, P E; Giaccone, G

    This report describes the validation of a polymerase chain reaction aided transcript titration assay (PATTY) for tumor samples. The results obtained with the PATTY were compared to those of RNase protection in a set of 7 human lung cancer cell lines and in 23 non-small cell lung cancer samples derived from resected patients. Whereas between PATTY and RNase protection assay a good correlation was observed in the cell lines (r = 0.74, p = 0.057), no correlation was observed within the tumor samples (r = 0.06, p = 0.78). This was also the case when only tumors with a high percentage of tumor cells (> 90%) were selected. Although PATTY is a valuable tool to measure mRNA expression in cell lines, our results caution the use of PATTY in human tumor samples without proper validation. The possible causes of these results are discussed.

  19. Advantage of multiple spot urine collections for estimating daily sodium excretion: comparison with two 24-h urine collections as reference.

    PubMed

    Uechi, Ken; Asakura, Keiko; Ri, Yui; Masayasu, Shizuko; Sasaki, Satoshi

    2016-02-01

    Several estimation methods for 24-h sodium excretion using spot urine sample have been reported, but accurate estimation at the individual level remains difficult. We aimed to clarify the most accurate method of estimating 24-h sodium excretion with different numbers of available spot urine samples. A total of 370 participants from throughout Japan collected multiple 24-h urine and spot urine samples independently. Participants were allocated randomly into a development and a validation dataset. Two estimation methods were established in the development dataset using the two 24-h sodium excretion samples as reference: the 'simple mean method' estimated by multiplying the sodium-creatinine ratio by predicted 24-h creatinine excretion, whereas the 'regression method' employed linear regression analysis. The accuracy of the two methods was examined by comparing the estimated means and concordance correlation coefficients (CCC) in the validation dataset. Mean sodium excretion by the simple mean method with three spot urine samples was closest to that by 24-h collection (difference: -1.62  mmol/day). CCC with the simple mean method increased with an increased number of spot urine samples at 0.20, 0.31, and 0.42 using one, two, and three samples, respectively. This method with three spot urine samples yielded higher CCC than the regression method (0.40). When only one spot urine sample was available for each study participant, CCC was higher with the regression method (0.36). The simple mean method with three spot urine samples yielded the most accurate estimates of sodium excretion. When only one spot urine sample was available, the regression method was preferable.

  20. Portable automation of static chamber sample collection for quantifying soil gas flux

    USDA-ARS?s Scientific Manuscript database

    The collection of soil gas flux using the static chamber method is labor intensive. The number of chambers that can be sampled in a given time period is limited by the spacing between chambers and the availability of trained research technicians. However, the static chamber method can limit spatial ...

  1. Bioculture System Validation

    NASA Technical Reports Server (NTRS)

    Sato, Kevin Y.

    2012-01-01

    The Bioculture System first flight will be to validate the performance of the hardware and its automated and manual operational capabilities in the space flight environment of the International Space Station. Biology, Engineering, and Operations tests will be conducted in the Bioculture System fully characterize its automated and manual functions to support cell culturing for short and long durations. No hypothesis-driven research will be conducted with biological sample, and the science leads have all provided their concurrence that none of the data they collect will be considered as proprietary and can be free distributed to the science community. The outcome of the validation flight will be to commission the hardware for use by the science community. This presentation will provide non-proprietary details about the Bioculture System and information about the activities for the first flight.

  2. The development of the Athens Emotional States Inventory (AESI): collection, validation and automatic processing of emotionally loaded sentences.

    PubMed

    Chaspari, Theodora; Soldatos, Constantin; Maragos, Petros

    2015-01-01

    The development of ecologically valid procedures for collecting reliable and unbiased emotional data towards computer interfaces with social and affective intelligence targeting patients with mental disorders. Following its development, presented with, the Athens Emotional States Inventory (AESI) proposes the design, recording and validation of an audiovisual database for five emotional states: anger, fear, joy, sadness and neutral. The items of the AESI consist of sentences each having content indicative of the corresponding emotion. Emotional content was assessed through a survey of 40 young participants with a questionnaire following the Latin square design. The emotional sentences that were correctly identified by 85% of the participants were recorded in a soundproof room with microphones and cameras. A preliminary validation of AESI is performed through automatic emotion recognition experiments from speech. The resulting database contains 696 recorded utterances in Greek language by 20 native speakers and has a total duration of approximately 28 min. Speech classification results yield accuracy up to 75.15% for automatically recognizing the emotions in AESI. These results indicate the usefulness of our approach for collecting emotional data with reliable content, balanced across classes and with reduced environmental variability.

  3. Outward Bound Outcome Model Validation and Multilevel Modeling

    ERIC Educational Resources Information Center

    Luo, Yuan-Chun

    2011-01-01

    This study was intended to measure construct validity for the Outward Bound Outcomes Instrument (OBOI) and to predict outcome achievement from individual characteristics and course attributes using multilevel modeling. A sample of 2,340 participants was collected by Outward Bound USA between May and September 2009 using the OBOI. Two phases of…

  4. Diagnosing Autism in Adults with Intellectual Disability: Validation of the DiBAS-R in an Independent Sample

    ERIC Educational Resources Information Center

    Heinrich, Manuel; Böhm, Julia; Sappok, Tanja

    2018-01-01

    The study assessed the diagnostic validity of the diagnostic behavioral assessment for autism spectrum disorders-revised (DiBAS-R; 19-item screening scale based on ratings by caregivers) in a clinical sample of 381 adults with ID. Analysis revealed a sensitivity of 0.82 and a specificity of 0.67 in the overall sample (70.3% agreement). Sensitivity…

  5. Validity of the Multidimensional Fatigue Symptom Inventory-Short Form in an African American Community-Based Sample

    PubMed Central

    Asvat, Yasmin; Malcarne, Vanessa L.; Sadler, Georgia R.; Jacobsen, Paul B.

    2014-01-01

    Objectives This study examined the psychometric properties of the Multidimensional Fatigue Symptom Inventory-Short Form (MFSI-SF) in a community-based sample of African Americans. Design. A sample of 340 African Americans (116 men, 224 women) ranging in age from 18–81 years were recruited from the community (e.g., churches, health fairs, beauty salons). Participants completed a brief demographic survey, the MFSI-SF and the Positive and Negative Affect Schedule. Results The structural validity of the MFSI-SF for a community-based sample of African Americans was not supported. The five dimensions of fatigue (General, Emotional, Physical, Mental, Vigor) found for Whites in prior research were not found for African Americans in this study. Instead, fatigue, while multidimensional for African Americans, was best represented by a unique four-four profile in which general and emotional fatigue are collapsed into a single dimension and physical fatigue, mental fatigue, and vigor are relatively distinct. Hence, in the absence of modifications, the MFSI-SF cannot be considered to be structurally invariant across ethnic groups. A modified four-factor version of the MFSI-SF exhibited excellent internal consistency reliability and evidence supports its convergent validity. Using the modified four-factor version, gender and age were not meaningfully associated with MFSI-SF scores. Conclusion Future research should further examine whether modifications to the MFSI-SF would, as the findings suggest, improve its validity as a measure of multidimensional fatigue in African Americans. PMID:24527980

  6. Developmental validation of the DNAscan™ Rapid DNA Analysis™ instrument and expert system for reference sample processing.

    PubMed

    Della Manna, Angelo; Nye, Jeffrey V; Carney, Christopher; Hammons, Jennifer S; Mann, Michael; Al Shamali, Farida; Vallone, Peter M; Romsos, Erica L; Marne, Beth Ann; Tan, Eugene; Turingan, Rosemary S; Hogan, Catherine; Selden, Richard F; French, Julie L

    2016-11-01

    Since the implementation of forensic DNA typing in labs more than 20 years ago, the analysis procedures and data interpretation have always been conducted in a laboratory by highly trained and qualified scientific personnel. Rapid DNA technology has the potential to expand testing capabilities within forensic laboratories and to allow forensic STR analysis to be performed outside the physical boundaries of the traditional laboratory. The developmental validation of the DNAscan/ANDE Rapid DNA Analysis System was completed using a BioChipSet™ Cassette consumable designed for high DNA content samples, such as single source buccal swabs. A total of eight laboratories participated in the testing which totaled over 2300 swabs, and included nearly 1400 unique individuals. The goal of this extensive study was to obtain, document, analyze, and assess DNAscan and its internal Expert System to reliably genotype reference samples in a manner compliant with the FBI's Quality Assurance Standards (QAS) and the NDIS Operational Procedures. The DNAscan System provided high quality, concordant results for reference buccal swabs, including automated data analysis with an integrated Expert System. Seven external laboratories and NetBio, the developer of the technology, participated in the validation testing demonstrating the reproducibility and reliability of the system and its successful use in a variety of settings by numerous operators. The DNAscan System demonstrated limited cross reactivity with other species, was resilient in the presence of numerous inhibitors, and provided reproducible results for both buccal and purified DNA samples with sensitivity at a level appropriate for buccal swabs. The precision and resolution of the system met industry standards for detection of micro-variants and displayed single base resolution. PCR-based studies provided confidence that the system was robust and that the amplification reaction had been optimized to provide high quality results

  7. Impact of Use of Smaller Volume, Smaller Vacuum Blood Collection Tubes on Hemolysis in Emergency Department Blood Samples.

    PubMed

    Phelan, Michael P; Reineks, Edmunds Z; Berriochoa, Jacob P; Schold, Jesse D; Hustey, Fredric M; Chamberlin, Janelle; Kovach, Annmarie

    2017-10-01

    Hemolyzed blood samples commonly occur in hospital emergency departments (EDs). Our objective was to determine whether replacing standard large-volume/high-vacuum sample tubes with low-volume/low-vacuum tubes would significantly affect ED hemolysis. This was a prospective intervention of the use of small-volume/vacuum collection tubes. We evaluated all potassium samples in ED patients and associated hemolysis. We used χ2 tests to compare hemolysis incidence prior to and following utilization of small tubes for chemistry collection. There were 35,481 blood samples collected during the study period. Following implementation of small-volume tubes, overall hemolysis decreased from a baseline of 11.8% to 2.9% (P < .001) with corresponding reductions in hemolysis with comment (8.95% vs 1.99%; P < .001) gross hemolysis (2.84% vs 0.90%; P < .007). This work demonstrates that significant improvements in ED hemolysis can be achieved by utilization of small-volume/vacuum sample collection tubes. © American Society for Clinical Pathology, 2017. All rights reserved. For permissions, please e-mail: journals.permissions@oup.com

  8. Swab or biopsy samples for bioburden testing of allograft musculoskeletal tissue?

    PubMed

    Varettas, Kerry

    2014-12-01

    Swab and biopsy samples of allograft musculoskeletal tissue are most commonly collected by tissue banks for bacterial and fungal bioburden testing. An in vitro study was performed using the National Committee for Clinical Laboratory Standards standard 'Quality control of microbiological transport systems' (2003) to validate and evaluate the recovery of six challenge organisms from swab and biopsy samples of allograft musculoskeletal tissue. On average, 8.4 to >100 and 7.2 to >100 % of the inoculum was recovered from swab and biopsy samples respectively. A retrospective review of donor episodes was also performed, consisting of paired swab and biopsy samples received in this laboratory during the period 2001-2012. Samples of allograft femoral heads were collected from living donors during hip operations. From the 3,859 donor episodes received, 21 paired swab and biopsy samples each recovered an isolate, 247 swab samples only and 79 biopsy samples only were culture positive. Low numbers of challenge organisms were recovered from inoculated swab and biopsy samples in the in vitro study and validated their use for bioburden testing of allograft musculoskeletal tissue. Skin commensals were the most common group of organisms isolated during a 12-year retrospective review of paired swab and biopsy samples from living donor allograft femoral heads. Paired swab and biopsy samples are a suitable representative sample of allograft musculoskeletal tissue for bioburden testing.

  9. A Prototype Ice-Melting Probe for Collecting Biological Samples from Cryogenic Ice at Low Pressure.

    PubMed

    Davis, Ashley

    2017-08-01

    In the Solar System, the surface of an icy moon is composed of irregular ice formations at cryogenic temperatures (<200 K), with an oxidized surface layer and a tenuous atmosphere at very low pressure (<10 -6 atm). A lander mission, whose aim is to collect and analyze biological samples from the surface ice, must contain a device that collects samples without refreezing liquid and without sublimation of ice. In addition, if the samples are biological in nature, then precautions must be taken to ensure the samples do not overheat or mix with the oxidized layer. To achieve these conditions, the collector must maintain temperatures close to maintenance or growth conditions of the organism (<293 K), and it must separate or neutralize the oxidized layer and be physically gentle. Here, we describe a device that addresses these requirements and is compatible with low atmospheric pressure while using no pumps. The device contains a heated conical probe with a central orifice, which is forced into surface ice and directs the meltwater upward into a reservoir. The force on the probe is proportional to the height of meltwater (pressure) obtained in the system and allows regulation of the melt rate and temperature of the sample. The device can collect 5-50 mL of meltwater from the surface of an ice block at 233-208 K with an environmental pressure of less than 10 -2 atm while maintaining a sample temperature between 273 and 293 K. These conditions maintain most biological samples in a pristine state and maintain the integrity of most organisms' structure and function. Key Words: Europa-Icy moon-Microbe-Eukaryote-Spacecraft. Astrobiology 17, 709-720.

  10. Physical Validation of TRMM TMI and PR Monthly Rain Products Over Oklahoma

    NASA Technical Reports Server (NTRS)

    Fisher, Brad L.

    2004-01-01

    The Tropical Rainfall Measuring Mission (TRMM) provides monthly rainfall estimates using data collected by the TRMM satellite. These estimates cover a substantial fraction of the earth's surface. The physical validation of TRMM estimates involves corroborating the accuracy of spaceborne estimates of areal rainfall by inferring errors and biases from ground-based rain estimates. The TRMM error budget consists of two major sources of error: retrieval and sampling. Sampling errors are intrinsic to the process of estimating monthly rainfall and occur because the satellite extrapolates monthly rainfall from a small subset of measurements collected only during satellite overpasses. Retrieval errors, on the other hand, are related to the process of collecting measurements while the satellite is overhead. One of the big challenges confronting the TRMM validation effort is how to best estimate these two main components of the TRMM error budget, which are not easily decoupled. This four-year study computed bulk sampling and retrieval errors for the TRMM microwave imager (TMI) and the precipitation radar (PR) by applying a technique that sub-samples gauge data at TRMM overpass times. Gridded monthly rain estimates are then computed from the monthly bulk statistics of the collected samples, providing a sensor-dependent gauge rain estimate that is assumed to include a TRMM equivalent sampling error. The sub-sampled gauge rain estimates are then used in conjunction with the monthly satellite and gauge (without sub- sampling) estimates to decouple retrieval and sampling errors. The computed mean sampling errors for the TMI and PR were 5.9% and 7.796, respectively, in good agreement with theoretical predictions. The PR year-to-year retrieval biases exceeded corresponding TMI biases, but it was found that these differences were partially due to negative TMI biases during cold months and positive TMI biases during warm months.

  11. Further development and construct validation of MMPI-2-RF indices of global psychopathy, fearless-dominance, and impulsive-antisociality in a sample of incarcerated women.

    PubMed

    Phillips, Tasha R; Sellbom, Martin; Ben-Porath, Yossef S; Patrick, Christopher J

    2014-02-01

    Replicating and extending research by Sellbom et al. (M. Sellbom, Y. S. Ben-Porath, C. J. Patrick, D. B. Wygant, D. M. Gartland, & K. P. Stafford, 2012, Development and Construct Validation of the MMPI-2-RF Measures of Global Psychopathy, Fearless-Dominance, and Impulsive-Antisociality, Personality Disorders: Theory, Research, and Treatment, 3, 17-38), the current study examined the criterion-related validity of three self-report indices of psychopathy that were derived from scores on the Minnesota Multiphasic Personality Inventory (MMPI)-2-Restructured Form (MMPI-2-RF; Y. S. Ben-Porath & A. Tellegen, 2008, Minnesota Multiphasic Personality Inventory-2-Restructured Form: Manual for Administration, Scoring, and Interpretation, Minneapolis, MN: University of Minnesota Press). We estimated psychopathy indices by regressing scores from the Psychopathic Personality Inventory (PPI; S. O. Lilienfeld & B. P. Andrews, 1996, Development and Preliminary Validation of a Self-Report Measure of Psychopathic Personality Traits in Noncriminal Populations, Journal of Personality Assessment, 66, 488-524) and its two distinct facets, Fearless-Dominance and Impulsive-Antisociality, onto conceptually selected MMPI-2-RF scales. Data for a newly collected sample of 230 incarcerated women were combined with existing data from Sellbom et al.'s (2012) male correctional and mixed-gender college samples to establish regression equations with optimal generalizability. Correlation and regression analyses were then used to examine associations between the MMPI-2-RF-based estimates of PPI psychopathy and criterion measures (i.e., other well-established measures of psychopathy and conceptually related personality traits), and to evaluate whether gender moderated these associations. The MMPI-2-RF-based psychopathy indices correlated as expected with criterion measures and showed only one significant moderating effect for gender, namely, in the association between psychopathy and narcissism. These

  12. A Brief Measure of Peer Affiliation and Social Acceptance (PASA): Validity in an Ethnically Diverse Sample of Early Adolescents

    PubMed Central

    Dishion, Thomas J.; Kim, Hanjoe; Stormshak, Elizabeth A.; O'Neill, Maya

    2014-01-01

    Objective Conduct a multiagent–multimethod analysis of the validity of a brief measure of deviant peer affiliations and social acceptance (PASA) in young adolescents. Peer relationships are critical to child and adolescent social and emotional development, but currently available measures are tedious and time consuming. The PASA consists of a youth, parent, and teacher report that can be collected longitudinally to study development and intervention effectiveness. Method This longitudinal study included 998 middle school students and their families. We collected the PASA and peer sociometrics data in Grade 7 and a multiagent–multimethod construct of deviant peer clustering in Grade 8. Results Confirmatory factor analyses of the multiagent–multimethod data revealed that the constructs of deviant peer affiliations and social acceptance and rejection were distinguishable as unique but correlated constructs within the PASA. Convergent, discriminant, concurrent, and predictive validity of the PASA was satisfactory, although the acceptance and rejection constructs were highly correlated and showed similar patterns of concurrent validity. Factor invariance was established for mother and for father reports. Conclusions Results suggest that the PASA is a valid and reliable measure of peer affiliation and of social acceptance among peers during the middle school years and provides a comprehensive yet brief assessment of peer affiliations and social acceptance. PMID:24611623

  13. Joint use of over- and under-sampling techniques and cross-validation for the development and assessment of prediction models.

    PubMed

    Blagus, Rok; Lusa, Lara

    2015-11-04

    Prediction models are used in clinical research to develop rules that can be used to accurately predict the outcome of the patients based on some of their characteristics. They represent a valuable tool in the decision making process of clinicians and health policy makers, as they enable them to estimate the probability that patients have or will develop a disease, will respond to a treatment, or that their disease will recur. The interest devoted to prediction models in the biomedical community has been growing in the last few years. Often the data used to develop the prediction models are class-imbalanced as only few patients experience the event (and therefore belong to minority class). Prediction models developed using class-imbalanced data tend to achieve sub-optimal predictive accuracy in the minority class. This problem can be diminished by using sampling techniques aimed at balancing the class distribution. These techniques include under- and oversampling, where a fraction of the majority class samples are retained in the analysis or new samples from the minority class are generated. The correct assessment of how the prediction model is likely to perform on independent data is of crucial importance; in the absence of an independent data set, cross-validation is normally used. While the importance of correct cross-validation is well documented in the biomedical literature, the challenges posed by the joint use of sampling techniques and cross-validation have not been addressed. We show that care must be taken to ensure that cross-validation is performed correctly on sampled data, and that the risk of overestimating the predictive accuracy is greater when oversampling techniques are used. Examples based on the re-analysis of real datasets and simulation studies are provided. We identify some results from the biomedical literature where the incorrect cross-validation was performed, where we expect that the performance of oversampling techniques was heavily

  14. Examination of the MMPI-2 restructured form (MMPI-2-RF) validity scales in civil forensic settings: findings from simulation and known group samples.

    PubMed

    Wygant, Dustin B; Ben-Porath, Yossef S; Arbisi, Paul A; Berry, David T R; Freeman, David B; Heilbronner, Robert L

    2009-11-01

    The current study examined the effectiveness of the MMPI-2 Restructured Form (MMPI-2-RF; Ben-Porath and Tellegen, 2008) over-reporting indicators in civil forensic settings. The MMPI-2-RF includes three revised MMPI-2 over-reporting validity scales and a new scale to detect over-reported somatic complaints. Participants dissimulated medical and neuropsychological complaints in two simulation samples, and a known-groups sample used symptom validity tests as a response bias criterion. Results indicated large effect sizes for the MMPI-2-RF validity scales, including a Cohen's d of .90 for Fs in a head injury simulation sample, 2.31 for FBS-r, 2.01 for F-r, and 1.97 for Fs in a medical simulation sample, and 1.45 for FBS-r and 1.30 for F-r in identifying poor effort on SVTs. Classification results indicated good sensitivity and specificity for the scales across the samples. This study indicates that the MMPI-2-RF over-reporting validity scales are effective at detecting symptom over-reporting in civil forensic settings.

  15. Method validation for control determination of mercury in fresh fish and shrimp samples by solid sampling thermal decomposition/amalgamation atomic absorption spectrometry.

    PubMed

    Torres, Daiane Placido; Martins-Teixeira, Maristela Braga; Cadore, Solange; Queiroz, Helena Müller

    2015-01-01

    A method for the determination of total mercury in fresh fish and shrimp samples by solid sampling thermal decomposition/amalgamation atomic absorption spectrometry (TDA AAS) has been validated following international foodstuff protocols in order to fulfill the Brazilian National Residue Control Plan. The experimental parameters have been previously studied and optimized according to specific legislation on validation and inorganic contaminants in foodstuff. Linearity, sensitivity, specificity, detection and quantification limits, precision (repeatability and within-laboratory reproducibility), robustness as well as accuracy of the method have been evaluated. Linearity of response was satisfactory for the two range concentrations available on the TDA AAS equipment, between approximately 25.0 and 200.0 μg kg(-1) (square regression) and 250.0 and 2000.0 μg kg(-1) (linear regression) of mercury. The residues for both ranges were homoscedastic and independent, with normal distribution. Correlation coefficients obtained for these ranges were higher than 0.995. Limits of quantification (LOQ) and of detection of the method (LDM), based on signal standard deviation (SD) for a low-in-mercury sample, were 3.0 and 1.0 μg kg(-1), respectively. Repeatability of the method was better than 4%. Within-laboratory reproducibility achieved a relative SD better than 6%. Robustness of the current method was evaluated and pointed sample mass as a significant factor. Accuracy (assessed as the analyte recovery) was calculated on basis of the repeatability, and ranged from 89% to 99%. The obtained results showed the suitability of the present method for direct mercury measurement in fresh fish and shrimp samples and the importance of monitoring the analysis conditions for food control purposes. Additionally, the competence of this method was recognized by accreditation under the standard ISO/IEC 17025.

  16. Miniature Blimps for Surveillance and Collection of Samples

    NASA Technical Reports Server (NTRS)

    Jones, Jack

    2004-01-01

    Miniature blimps are under development as robots for use in exploring the thick, cold, nitrogen atmosphere of Saturn's moon, Titan. Similar blimps can also be used for surveillance and collection of biochemical samples in buildings, caves, subways, and other, similar structures on Earth. The widely perceived need for means to thwart attacks on buildings and to mitigate the effects of such attacks has prompted consideration of the use of robots. Relative to rover-type (wheeled) robots that have been considered for such uses, miniature blimps offer the advantage of ability to move through the air in any direction and, hence, to perform tasks that are difficult or impossible for wheeled robots, including climbing stairs and looking through windows. In addition, miniature blimps are expected to have greater range and to cost less, relative to wheeled robots.

  17. Examination of the Structural, Convergent, and Incremental Validity of the Reynolds Intellectual Assessment Scales (RIAS) with a Clinical Sample

    ERIC Educational Resources Information Center

    Nelson, Jason M.; Canivez, Gary L.

    2012-01-01

    Empirical examination of the Reynolds Intellectual Assessment Scales (RIAS; C. R. Reynolds & R. W. Kamphaus, 2003a) has produced mixed results regarding its internal structure and convergent validity. Various aspects of validity of RIAS scores with a sample (N = 521) of adolescents and adults seeking psychological evaluations at a university-based…

  18. Landspotting: Social gaming to collect vast amounts of data for satellite validation

    NASA Astrophysics Data System (ADS)

    Fritz, S.; Purgathofer, P.; Kayali, F.; Fellner, M.; Wimmer, M.; Sturn, T.; Triebnig, G.; Krause, S.; Schindler, F.; Kollegger, M.; Perger, C.; Dürauer, M.; Haberl, W.; See, L.; McCallum, I.

    2012-04-01

    At present there is no single satellite-derived global land cover product that is accurate enough to provide reliable estimates of forest or cropland area to determine, e.g., how much additional land is available to grow biofuels or to tackle problems of food security. The Landspotting Project aims to improve the quality of this land cover information by vastly increasing the amount of in-situ validation data available for calibration and validation of satellite-derived land cover. The Geo-Wiki (Geo-Wiki.org) system currently allows users to compare three satellite derived land cover products and validate them using Google Earth. However, there is presently no incentive for anyone to provide this data so the amount of validation through Geo-Wiki has been limited. However, recent competitions have proven that incentive driven campaigns can rapidly create large amounts of input. The LandSpotting Project is taking a truly innovative approach through the development of the Landspotting game. The game engages users whilst simultaneously collecting a large amount of in-situ land cover information. The development of the game is informed by the current raft of successful social gaming that is available on the internet and as mobile applications, many of which are geo-spatial in nature. Games that are integrated within a social networking site such as Facebook illustrate the power to reach and continually engage a large number of individuals. The number of active Facebook users is estimated to be greater than 400 million, where 100 million are accessing Facebook from mobile devices. The Landspotting Game has similar game mechanics as the famous strategy game "Civilization" (i.e. build, harvest, research, war, diplomacy, etc.). When a player wishes to make a settlement, they must first classify the land cover over the area they wish to settle. As the game is played on the earth surface with Google Maps, we are able to record and store this land cover/land use classification

  19. Collecting a better water-quality sample: Reducing vertical stratification bias in open and closed channels

    USGS Publications Warehouse

    Selbig, William R.

    2017-01-01

    Collection of water-quality samples that accurately characterize average particle concentrations and distributions in channels can be complicated by large sources of variability. The U.S. Geological Survey (USGS) developed a fully automated Depth-Integrated Sample Arm (DISA) as a way to reduce bias and improve accuracy in water-quality concentration data. The DISA was designed to integrate with existing autosampler configurations commonly used for the collection of water-quality samples in vertical profile thereby providing a better representation of average suspended sediment and sediment-associated pollutant concentrations and distributions than traditional fixed-point samplers. In controlled laboratory experiments, known concentrations of suspended sediment ranging from 596 to 1,189 mg/L were injected into a 3 foot diameter closed channel (circular pipe) with regulated flows ranging from 1.4 to 27.8 ft3 /s. Median suspended sediment concentrations in water-quality samples collected using the DISA were within 7 percent of the known, injected value compared to 96 percent for traditional fixed-point samplers. Field evaluation of this technology in open channel fluvial systems showed median differences between paired DISA and fixed-point samples to be within 3 percent. The range of particle size measured in the open channel was generally that of clay and silt. Differences between the concentration and distribution measured between the two sampler configurations could potentially be much larger in open channels that transport larger particles, such as sand.

  20. 75 FR 59294 - Comment Request for Information Collection for The Data Validation Requirement for Employment and...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-09-27

    ...The Department of Labor, as part of its continuing effort to reduce paperwork and respondent burden, conducts a preclearance consultation program to provide the general public and Federal agencies with an opportunity to comment on proposed and/or continuing collections of information in accordance with the Paperwork Reduction Act of 1995 (PRA95) [44 U.S.C. 3506(c)(2)(A)]. This program helps to ensure that requested data can be provided in the desired format, reporting burden (time and financial resources) is minimized, collection instruments are clearly understood, and the impact of collection requirements on respondents can be properly assessed. Currently, the Employment and Training Administration is soliciting comments concerning the collection of data validation for the following employment and training programs: Workforce Investment Act (WIA) Title IB, Wagner-Peyser, Trade Adjustment Assistance (TAA), National Farmworker Jobs Program (NFJP) and Senior Community Service Employment Program (SCSEP). The current expiration date is February 28, 2011. A copy of the proposed information collection request (ICR) can be obtained by contacting the office listed below in the addresses section of this notice.

  1. Results of chemical and stable isotopic analyses of water samples collected in the Patagonia Mountains, southern Arizona

    USGS Publications Warehouse

    Wanty, Richard B.; Shanks, Wayne C.; Lamothe, Paul; Meier, A.L.; Lichte, Fred; Briggs, Paul H.; Berger, Byron R.

    2001-01-01

    Water samples were collected in the Patagonia Mountains in February, 1997. Most of the samples were collected from portals of abandoned mines, or from stream drainages immediately downstream from abandoned mines. Most of the samples have low pH ( 1000 mg/L). Anion composition of the water samples is dominated by sulfate, while cation compositions range from calcium-dominated to mixed calcium-magnesium or calcium-sodium-dominated waters. Metals such as iron, manganese, copper, zinc, and aluminum contribute a significant portion (>10%) of the cation content to the water samples. Because of the low pH?s, protons contribute up to several percent of the cation character of the waters in some of the samples. The data are presented in tabular and graphical formats, with descriptions of data quality and brief descriptions of results.

  2. K(3)EDTA Vacuum Tubes Validation for Routine Hematological Testing.

    PubMed

    Lima-Oliveira, Gabriel; Lippi, Giuseppe; Salvagno, Gian Luca; Montagnana, Martina; Poli, Giovanni; Solero, Giovanni Pietro; Picheth, Geraldo; Guidi, Gian Cesare

    2012-01-01

    Background and Objective. Some in vitro diagnostic devices (e.g, blood collection vacuum tubes and syringes for blood analyses) are not validated before the quality laboratory managers decide to start using or to change the brand. Frequently, the laboratory or hospital managers select the vacuum tubes for blood collection based on cost considerations or on relevance of a brand. The aim of this study was to validate two dry K(3)EDTA vacuum tubes of different brands for routine hematological testing. Methods. Blood specimens from 100 volunteers in two different K(3)EDTA vacuum tubes were collected by a single, expert phlebotomist. The routine hematological testing was done on Advia 2120i hematology system. The significance of the differences between samples was assessed by paired Student's t-test after checking for normality. The level of statistical significance was set at P < 0.05. Results and Conclusions. Different brand's tubes evaluated can represent a clinically relevant source of variations only on mean platelet volume (MPV) and platelet distribution width (PDW). Basically, our validation will permit the laboratory or hospital managers to select the brand's vacuum tubes validated according to him/her technical or economical reasons for routine hematological tests.

  3. Construct Validity of the Nutrition and Activity Knowledge Scale in a French Sample of Adolescents with Mild to Moderate Intellectual Disability

    ERIC Educational Resources Information Center

    Maiano, Christophe; Begarie, Jerome; Morin, Alexandre J. S.; Garbarino, Jean-Marie; Ninot, Gregory

    2010-01-01

    The purpose of this study was to test the reliability (i.e. internal consistency and test-retest reliability) and construct validity (i.e. content validity, factor validity, measurement invariance, and latent mean invariance) of the Nutrition and Activity Knowledge Scale (NAKS) in a sample of French adolescents with mild to moderate Intellectual…

  4. A Systematic Review of Published Respondent-Driven Sampling Surveys Collecting Behavioral and Biologic Data.

    PubMed

    Johnston, Lisa G; Hakim, Avi J; Dittrich, Samantha; Burnett, Janet; Kim, Evelyn; White, Richard G

    2016-08-01

    Reporting key details of respondent-driven sampling (RDS) survey implementation and analysis is essential for assessing the quality of RDS surveys. RDS is both a recruitment and analytic method and, as such, it is important to adequately describe both aspects in publications. We extracted data from peer-reviewed literature published through September, 2013 that reported collected biological specimens using RDS. We identified 151 eligible peer-reviewed articles describing 222 surveys conducted in seven regions throughout the world. Most published surveys reported basic implementation information such as survey city, country, year, population sampled, interview method, and final sample size. However, many surveys did not report essential methodological and analytical information for assessing RDS survey quality, including number of recruitment sites, seeds at start and end, maximum number of waves, and whether data were adjusted for network size. Understanding the quality of data collection and analysis in RDS is useful for effectively planning public health service delivery and funding priorities.

  5. A Citizen Science Soil Moisture Sensor to Support SMAP Calibration/Validation

    NASA Astrophysics Data System (ADS)

    Podest, E.; Das, N. N.

    2016-12-01

    The Soil Moisture Active Passive (SMAP) satellite mission was launched in Jan. 2015 and is currently acquiring global measurements of soil moisture in the top 5 cm of the soil every 3 days. SMAP has partnered with the GLOBE program to engage students from around the world to collect in situ soil moisture and help validate SMAP measurements. The current GLOBE SMAP soil moisture protocol consists in collecting a soil sample, weighing, drying and weighing it again in order to determine the amount of water in the soil. Preparation and soil sample collection can take up to 20 minutes and drying can take up to 3 days. We have hence developed a soil moisture measurement device based on Arduino-like microcontrollers along with off-the-shelf and homemade sensors that are accurate, robust, inexpensive and quick and easy to use so that they can be implemented by the GLOBE community and citizen scientists alike. This talk will discuss building, calibration and validation of the soil moisture measuring device and assessing the quality of the measurements collected. This work was carried out at the Jet Propulsion Laboratory, California Institute of Technology, under contract with the National Aeronautics and Space Administration.

  6. Blood sample collection and patient identification demand improvement: a questionnaire study of preanalytical practices in hospital wards and laboratories.

    PubMed

    Wallin, Olof; Söderberg, Johan; Van Guelpen, Bethany; Stenlund, Hans; Grankvist, Kjell; Brulin, Christine

    2010-09-01

    Scand J Caring Sci; 2010; 24; 581-591 
 Blood sample collection and patient identification demand improvement: a questionnaire study of preanalytical practices in hospital wards and laboratories   Most errors in venous blood testing result from human mistakes occurring before the sample reach the laboratory.   To survey venous blood sampling (VBS) practices in hospital wards and to compare practices with hospital laboratories.   Staff in two hospitals (all wards) and two hospital laboratories (314 respondents, response rate 94%), completed a questionnaire addressing issues relevant to the collection of venous blood samples for clinical chemistry testing.   The findings suggest that instructions for patient identification and the collection of venous blood samples were not always followed. For example, 79% of the respondents reported the undesirable practice (UDP) of not always using wristbands for patient identification. Similarly, 87% of the respondents noted the UDP of removing venous stasis after the sampling is finished. Compared with the ward staff, a significantly higher proportion of the laboratory staff reported desirable practices regarding the collection of venous blood samples. Neither education nor the existence of established sampling routines was clearly associated with VBS practices among the ward staff.   The results of this study, the first of its kind, suggest that a clinically important risk of error is associated with VBS in the surveyed wards. Most important is the risk of misidentification of patients. Quality improvement of blood sample collection is clearly needed, particularly in hospital wards. © 2009 The Authors. Journal compilation © 2009 Nordic College of Caring Science.

  7. NEON Data Products: Supporting the Validation of GCOS Essential Climate Variables

    NASA Astrophysics Data System (ADS)

    Petroy, S. B.; Fox, A. M.; Metzger, S.; Thorpe, A.; Meier, C. L.

    2014-12-01

    The National Ecological Observatory Network (NEON) is a continental-scale ecological observation platform designed to collect and disseminate data that contributes to understanding and forecasting the impacts of climate change, land use change, and invasive species on ecology. NEON will collect in-situ and airborne data over 60 sites across the US, including Alaska, Hawaii, and Puerto Rico. The NEON Biomass, Productivity, and Biogeochemistry protocols currently direct the collection of samples from distributed, gradient, and tower plots at each site, with sampling occurring either multiple times during the growing season, annually, or on three- or five-year centers (e.g. for coarse woody debris). These data are processed into a series of field-derived data products (e.g. Biogeochemistry, LAI, above ground Biomass, etc.), and when combined with the NEON airborne hyperspectral and LiDAR imagery, are used support validation efforts of algorithms for deriving vegetation characteristics from the airborne data. Sites are further characterized using airborne data combined with in-situ tower measurements, to create additional data products of interest to the GCOS community, such as Albedo and fPAR. Presented here are a summary of tower/field/airborne sampling and observation protocols and examples of provisional datasets collected at NEON sites that may be used to support the ongoing validation of GCOS Essential Climate Variables.

  8. Effect of peripheral IV based blood collection on catheter dwell time, blood collection, and patient response.

    PubMed

    Mulloy, Deborah F; Lee, Susan M; Gregas, Matthew; Hoffman, Kate E; Ashley, Stanley W

    2018-04-01

    To evaluate the effect of daily PIV-based phlebotomy using the PIVO device on PIVC dwell times and replacement rates, as well as the reliability of blood sample collection, and patient response to this method of blood collection. Blood draws which are also known as phlebotomy for laboratory analyses are one of the most common experiences for hospitalized patients. When performed by venipuncture, they are often associated with pain and anxiety for patients. Most hospitals avoid phlebotomy from peripheral IV catheters due to sample hemolysis, sample dilution by fluids in PIVC line or infused medications, PIVC dislodgement or infiltration, and increased rates of phlebitis. A prospective, randomized- controlled study of 160 GI surgery patients was enrolled. Patients were randomized to either control evaluation of PIVC dwell or to receive daily PIVO blood collections in addition to evaluation of PIVC dwell. Daily PIVO blood collections did not negatively affect PIVC dwell or replacement rates. Overall 81% of blood collection attempts were successful and the likelihood of success was strongly associated with PIVC condition. Patients reported 0.7/10 pain for PIVO blood collection on a 0-10 pain scale and a 9.1/10 preference for PIVO on a 0 (strongly prefer needle) to 10 (strongly prefer PIVO) preference scale. Results suggest that use of a PIV based blood collection was a reliable and valid approach and was superior to routine phlebotomy in self-reported responses from patients. Copyright © 2018 The Authors. Published by Elsevier Inc. All rights reserved.

  9. The childhood executive function inventory: confirmatory factor analyses and cross-cultural clinical validity in a sample of 8- to 11-year-old children.

    PubMed

    Catale, Corinne; Meulemans, Thierry; Thorell, Lisa B

    2015-06-01

    The aim was to investigate the psychometric characteristics of the French adaptation of the Childhood Executive Functioning Inventory (CHEXI) in children and to explore the cross-cultural validity of the CHEXI in discriminating between children with ADHD and controls in two culturally different samples (Belgian and Swedish). Study I included normally developing children (n = 242), whereas Study II included both children diagnosed with ADHD (n = 87) and controls (n = 87). CHEXI ratings were collected from parents. Confirmatory factor analyses replicated the two-factor solution, referred to as inhibition and working memory, which had been identified previously. Both subscales had good psychometric properties. Furthermore, the CHEXI was found to discriminate, with high sensitivity and specificity, between children with ADHD and controls in both cultural samples. The CHEXI can be considered as a valuable screening measure for ADHD in children, but the cross-cultural clinical implications of ratings have to be considered. © 2013 SAGE Publications.

  10. Simultaneous quantification of stevioside and rebaudioside A in different stevia samples collected from the Indian subcontinent

    PubMed Central

    Chester, Karishma; Tamboli, Ennus T.; Singh, Mhaveer; Ahmad, Sayeed

    2012-01-01

    Background: A high performance thin layer chromatographic (HPTLC) method was developed for simultaneous estimation of stevioside and rebaudioside A in Stevia rebaudiana samples collected from different regions of Indian subcontinent. Materials and Methods: The separation was achieved by using acetone: ethyl acetate: water (5:4:1, v/v/v) as the solvent system on precoated silica gel 60 F254 TLC plates. The densitometric quantification of stevia glycosides was carried out at wavelength 360 nm in absorption mode after spraying with anisaldehyde sulphuric acid as detecting reagent. Results: The well resolved peaks for stevioside and rebaudioside A were observed at Rf values 0.31± 0.02 and 0.21± 0.02 respectively. The calibration curves were found linear with a wide range of concentration 100 - 2000 ng spot-1 with good correlation coefficient 0.996 and 0.991 for stevioside and rebaudioside A, respectively. Conclusions: The proposed method was validated as per the ICH (International Conferences on Harmonization) guidelines and found simple, sensitive, economic, reproducible, robust and accurate for quantitative analysis of stevia glycosides, which can be applied for quality control of stevia as well as to check. PMID:23248559

  11. Airborne environmental endotoxin: a cross-validation of sampling and analysis techniques.

    PubMed Central

    Walters, M; Milton, D; Larsson, L; Ford, T

    1994-01-01

    A standard method for measurement of airborne environmental endotoxin was developed and field tested in a fiberglass insulation-manufacturing facility. This method involved sampling with a capillary-pore membrane filter, extraction in buffer using a sonication bath, and analysis by the kinetic-Limulus assay with resistant-parallel-line estimation (KLARE). Cross-validation of the extraction and assay method was performed by comparison with methanolysis of samples followed by 3-hydroxy fatty acid (3-OHFA) analysis by gas chromatography-mass spectrometry. Direct methanolysis of filter samples and methanolysis of buffer extracts of the filters yielded similar 3-OHFA content (P = 0.72); the average difference was 2.1%. Analysis of buffer extracts for endotoxin content by the KLARE method and by gas chromatography-mass spectrometry for 3-OHFA content produced similar results (P = 0.23); the average difference was 0.88%. The source of endotoxin was gram-negative bacteria growing in recycled washwater used to clean the insulation-manufacturing equipment. The endotoxin and bacteria become airborne during spray cleaning operations. The types of 3-OHFAs in bacteria cultured from the washwater, present in the washwater and in the air, were similar. Virtually all of the bacteria cultured from air and water were gram negative composed mostly of two species, Deleya aesta and Acinetobacter johnsonii. Airborne countable bacteria correlated well with endotoxin (r2 = 0.64). Replicate sampling showed that results with the standard sampling, extraction, and Limulus assay by the KLARE method were highly reproducible (95% confidence interval for endotoxin measurement +/- 0.28 log10). These results demonstrate the accuracy, precision, and sensitivity of the standard procedure proposed for airborne environmental endotoxin. PMID:8161191

  12. Validation of Procedures for Monitoring Crewmember Immune Function - Short Duration Biological Investigation

    NASA Technical Reports Server (NTRS)

    Sams, Clarence; Crucian, Brian; Stowe, Raymond; Pierson, Duane; Mehta, Satish; Morukov, Boris; Uchakin, Peter; Nehlsen-Cannarella, Sandra

    2008-01-01

    Validation of Procedures for Monitoring Crew Member Immune Function - Short Duration Biological Investigation (Integrated Immune-SDBI) will assess the clinical risks resulting from the adverse effects of space flight on the human immune system and will validate a flightcompatible immune monitoring strategy. Immune system changes will be monitored by collecting and analyzing blood, urine and saliva samples from crewmembers before, during and after space flight.

  13. Collection of Aerosolized Human Cytokines Using Teflon® Filters

    PubMed Central

    McKenzie, Jennifer H.; McDevitt, James J.; Fabian, M. Patricia; Hwang, Grace M.; Milton, Donald K.

    2012-01-01

    Background Collection of exhaled breath samples for the analysis of inflammatory biomarkers is an important area of research aimed at improving our ability to diagnose, treat and understand the mechanisms of chronic pulmonary disease. Current collection methods based on condensation of water vapor from exhaled breath yield biomarker levels at or near the detection limits of immunoassays contributing to problems with reproducibility and validity of biomarker measurements. In this study, we compare the collection efficiency of two aerosol-to-liquid sampling devices to a filter-based collection method for recovery of dilute laboratory generated aerosols of human cytokines so as to identify potential alternatives to exhaled breath condensate collection. Methodology/Principal Findings Two aerosol-to-liquid sampling devices, the SKC® Biosampler and Omni 3000™, as well as Teflon® filters were used to collect aerosols of human cytokines generated using a HEART nebulizer and single-pass aerosol chamber setup in order to compare the collection efficiencies of these sampling methods. Additionally, methods for the use of Teflon® filters to collect and measure cytokines recovered from aerosols were developed and evaluated through use of a high-sensitivity multiplex immunoassay. Our results show successful collection of cytokines from pg/m3 aerosol concentrations using Teflon® filters and measurement of cytokine levels in the sub-picogram/mL concentration range using a multiplex immunoassay with sampling times less than 30 minutes. Significant degradation of cytokines was observed due to storage of cytokines in concentrated filter extract solutions as compared to storage of dry filters. Conclusions Use of filter collection methods resulted in significantly higher efficiency of collection than the two aerosol-to-liquid samplers evaluated in our study. The results of this study provide the foundation for a potential new technique to evaluate biomarkers of inflammation in

  14. NHEXAS PHASE I ARIZONA STUDY--STANDARD OPERATING PROCEDURE FOR REIMBURSEMENT FOR FIELD COLLECTION OF FOOD SAMPLES (UA-F-23.1)

    EPA Science Inventory

    The purpose of this SOP is to provide a uniform procedure for the financial reimbursement of primary respondents for the collection of diet samples. Respondents were reimbursed for replicate food and beverage samples by type and amount collected over a 24-hour sampling period. ...

  15. Reliability, factor structure, and validity of the German version of the Trauma Symptom Checklist for Children in a sample of adolescents

    PubMed Central

    Matulis, Simone; Loos, Laura; Langguth, Nadine; Schreiber, Franziska; Gutermann, Jana; Gawrilow, Caterina; Steil, Regina

    2015-01-01

    Background The Trauma Symptom Checklist for Children (TSC-C) is the most widely used self-report scale to assess trauma-related symptoms in children and adolescents on six clinical scales. The purpose of the present study was to develop a German version of the TSC-C and to investigate its psychometric properties, such as factor structure, reliability, and validity, in a sample of German adolescents. Method A normative sample of N=583 and a clinical sample of N=41 adolescents with a history of physical or sexual abuse aged between 13 and 21 years participated in the study. Results The Confirmatory Factor Analysis on the six-factor model (anger, anxiety, depression, dissociation, posttraumatic stress, and sexual concerns with the subdimensions preoccupation and distress) revealed acceptable to good fit statistics in the normative sample. One item had to be excluded from the German version of the TSC-C because the factor loading was too low. All clinical scales presented acceptable to good reliability, with Cronbach's α's ranging from .80 to .86 in the normative sample and from .72 to .87 in the clinical sample. Concurrent validity was also demonstrated by the high correlations between the TSC-C scales and instruments measuring similar psychopathology. TSC-C scores reliably differentiated between adolescents with trauma history and those without trauma history, indicating discriminative validity. Conclusions In conclusion, the German version of the TSC-C is a reliable and valid instrument for assessing trauma-related symptoms on six different scales in adolescents aged between 13 and 21 years. PMID:26498182

  16. Reliability, factor structure, and validity of the German version of the Trauma Symptom Checklist for Children in a sample of adolescents.

    PubMed

    Matulis, Simone; Loos, Laura; Langguth, Nadine; Schreiber, Franziska; Gutermann, Jana; Gawrilow, Caterina; Steil, Regina

    2015-01-01

    The Trauma Symptom Checklist for Children (TSC-C) is the most widely used self-report scale to assess trauma-related symptoms in children and adolescents on six clinical scales. The purpose of the present study was to develop a German version of the TSC-C and to investigate its psychometric properties, such as factor structure, reliability, and validity, in a sample of German adolescents. A normative sample of N=583 and a clinical sample of N=41 adolescents with a history of physical or sexual abuse aged between 13 and 21 years participated in the study. The Confirmatory Factor Analysis on the six-factor model (anger, anxiety, depression, dissociation, posttraumatic stress, and sexual concerns with the subdimensions preoccupation and distress) revealed acceptable to good fit statistics in the normative sample. One item had to be excluded from the German version of the TSC-C because the factor loading was too low. All clinical scales presented acceptable to good reliability, with Cronbach's α's ranging from .80 to .86 in the normative sample and from .72 to .87 in the clinical sample. Concurrent validity was also demonstrated by the high correlations between the TSC-C scales and instruments measuring similar psychopathology. TSC-C scores reliably differentiated between adolescents with trauma history and those without trauma history, indicating discriminative validity. In conclusion, the German version of the TSC-C is a reliable and valid instrument for assessing trauma-related symptoms on six different scales in adolescents aged between 13 and 21 years.

  17. Laboratory evaluation of sample collection methods (organs vs swabs) for Tasmanian salmon reovirus detection in farmed Atlantic salmon, Salmo salar L.

    PubMed

    Zainathan, S C; Carson, J; Crane, M St J; Nowak, B F

    2013-04-01

    The use of swabs relative to organs as a sample collection method for the detection of Tasmanian salmon reovirus (TSRV) in farmed Tasmanian Atlantic salmon, Salmo salar L., was evaluated by RT-qPCR. Evaluation of individual and pooled sample collection (organs vs swabs) was carried out to determine the sensitivity of the collection methods and the effect of pooling of samples for the detection of TSRV. Detection of TSRV in individual samples was as sensitive when organs were sampled compared to swabs, and in pooled samples, organs demonstrated a sensitivity of one 10-fold dilution higher than sampling of pooled swabs. Storage of swabs at 4 °C for t = 24 h demonstrated results similar to those at t = 0. Advantages of using swabs as a preferred sample collection method for the detection of TSRV compared to organ samples are evident from these experimental trials. © 2012 Blackwell Publishing Ltd.

  18. Next Generation Offline Approaches to Trace Gas-Phase Organic Compound Speciation: Sample Collection and Analysis

    NASA Astrophysics Data System (ADS)

    Sheu, R.; Marcotte, A.; Khare, P.; Ditto, J.; Charan, S.; Gentner, D. R.

    2017-12-01

    Intermediate-volatility and semi-volatile organic compounds (I/SVOCs) are major precursors to secondary organic aerosol, and contribute to tropospheric ozone formation. Their wide volatility range, chemical complexity, behavior in analytical systems, and trace concentrations present numerous hurdles to characterization. We present an integrated sampling-to-analysis system for the collection and offline analysis of trace gas-phase organic compounds with the goal of preserving and recovering analytes throughout sample collection, transport, storage, and thermal desorption for accurate analysis. Custom multi-bed adsorbent tubes are used to collect samples for offline analysis by advanced analytical detectors. The analytical instrumentation comprises an automated thermal desorption system that introduces analytes from the adsorbent tubes into a gas chromatograph, which is coupled with an electron ionization mass spectrometer (GC-EIMS) and other detectors. In order to optimize the collection and recovery for a wide range of analyte volatility and functionalization, we evaluated a variety of commercially-available materials, including Res-Sil beads, quartz wool, glass beads, Tenax TA, and silica gel. Key properties for optimization include inertness, versatile chemical capture, minimal affinity for water, and minimal artifacts or degradation byproducts; these properties were assessed with a diverse mix of traditionally-measured and functionalized analytes. Along with a focus on material selection, we provide recommendations spanning the entire sampling-and-analysis process to improve the accuracy of future comprehensive I/SVOC measurements, including oxygenated and other functionalized I/SVOCs. We demonstrate the performance of our system by providing results on speciated VOCs-SVOCs from indoor, outdoor, and chamber studies that establish the utility of our protocols and pave the way for precise laboratory characterization via a mix of detection methods.

  19. Validity of the WISC-IV Spanish for a clinically referred sample of Hispanic children.

    PubMed

    San Miguel Montes, Liza E; Allen, Daniel N; Puente, Antonio E; Neblina, Cris

    2010-06-01

    The Wechsler Intelligence Scale for Children (WISC) is the most commonly used intelligence test for children. Five years ago, a Spanish version of the WISC-IV was published (WISC-IV Spanish; Wechsler, 2005), but a limited amount of published information is available regarding its utility when assessing clinical samples. The current study included 107 children who were Spanish speaking and of Puerto Rican descent that had been administered the WISC-IV Spanish. They were subdivided into a clinical sample of 35 children with diagnoses of various forms of brain dysfunction (primarily learning disability, attention-deficit/hyperactivity disorder, and epilepsy) and a comparison group made up of 72 normal children who were part of the WISC-IV Spanish version standardization sample. Comparisons between these groups and the standardization sample were performed for the WISC-IV Spanish index and subtest scores. Results indicated that the clinical sample performed worse than the comparison samples on the Working Memory and Processing Speed Indexes, although findings varied to some extent depending on whether the clinical group was compared with the normal comparison group or the standardization sample. These findings provide support for the criterion validity of the WISC-IV Spanish when it is used to assess a clinically referred sample with brain dysfunction.

  20. Data Validation Package June 2016 Groundwater and Surface Water Sampling at the Old and New Rifle, Colorado, Processing Sites September 2016

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Bush, Richard; Lemke, Peter

    Sampling Period: June 14–17 and July 7, 2016. Water samples were collected from 36 locations at New Rifle and Old Rifle, Colorado, Disposal/Processing Sites. Planned monitoring locations are shown in Attachment 1, Sampling and Analysis Work Order. Duplicate samples were collected from New Rifle locations 0216 and 0855, and Old Rifle location 0655. One equipment blank was collected after decontamination of non-dedicated equipment used to collect one surface water sample. See Attachment 2, Trip Report for additional details. Sampling and analyses were conducted as specified in the Sampling and Analysis Plan for U.S. Department of Energy Office of Legacy Managementmore » Sites (LMS/PRO/S04351, continually updated, http://energy.gov/lm/downloads/sampling-and- analysis-plan-us-department-energy-office-legacy-management-sites). New Rifle Site Samples were collected at the New Rifle site from 16 monitoring wells and 7 surface locations in compliance with the December 2008 Groundwater Compliance Action Plan [GCAP] for the New Rifle, Colorado, Processing Site (LMS/RFN/S01920). Monitoring well 0216 could not be sampled in June because it was surrounded by standing water due to the high river stage from spring runoff, it was later sampled in July. Monitoring well 0635 and surface location 0322 could not be sampled because access through the elk fence along Interstate 70 has not been completed at this time. Old Rifle Site Samples were collected at the Old Rifle site from eight monitoring wells and five surface locations in compliance with the December 2001 Ground Water Compliance Action Plan for the Old Rifle, Colorado, UMTRA Project Site (GJ0-2000-177-TAR).« less

  1. Sampling algorithms for validation of supervised learning models for Ising-like systems

    NASA Astrophysics Data System (ADS)

    Portman, Nataliya; Tamblyn, Isaac

    2017-12-01

    In this paper, we build and explore supervised learning models of ferromagnetic system behavior, using Monte-Carlo sampling of the spin configuration space generated by the 2D Ising model. Given the enormous size of the space of all possible Ising model realizations, the question arises as to how to choose a reasonable number of samples that will form physically meaningful and non-intersecting training and testing datasets. Here, we propose a sampling technique called ;ID-MH; that uses the Metropolis-Hastings algorithm creating Markov process across energy levels within the predefined configuration subspace. We show that application of this method retains phase transitions in both training and testing datasets and serves the purpose of validation of a machine learning algorithm. For larger lattice dimensions, ID-MH is not feasible as it requires knowledge of the complete configuration space. As such, we develop a new ;block-ID; sampling strategy: it decomposes the given structure into square blocks with lattice dimension N ≤ 5 and uses ID-MH sampling of candidate blocks. Further comparison of the performance of commonly used machine learning methods such as random forests, decision trees, k nearest neighbors and artificial neural networks shows that the PCA-based Decision Tree regressor is the most accurate predictor of magnetizations of the Ising model. For energies, however, the accuracy of prediction is not satisfactory, highlighting the need to consider more algorithmically complex methods (e.g., deep learning).

  2. The Third Round of the Czech Validation of the Motivated Strategies for Learning Questionnaire (MSLQ)

    ERIC Educational Resources Information Center

    Vaculíková, Jitka

    2016-01-01

    The authors present findings on the third round of the Czech validation of the Motivated Strategies for learning questionnaire (MSLQ), originally developed by Pintrich et al. (1991). The validation only covered an area designed to access motivation in self-regulated learning. Data was collected from a sample of university students in regular…

  3. Validation of the TTM processes of change measure for physical activity in an adult French sample.

    PubMed

    Bernard, Paquito; Romain, Ahmed-Jérôme; Trouillet, Raphael; Gernigon, Christophe; Nigg, Claudio; Ninot, Gregory

    2014-04-01

    Processes of change (POC) are constructs from the transtheoretical model that propose to examine how people engage in a behavior. However, there is no consensus about a leading model explaining POC and there is no validated French POC scale in physical activity This study aimed to compare the different existing models to validate a French POC scale. Three studies, with 748 subjects included, were carried out to translate the items and evaluate their clarity (study 1, n = 77), to assess the factorial validity (n = 200) and invariance/equivalence (study 2, n = 471), and to analyze the concurrent validity by stage × process analyses (study 3, n = 671). Two models displayed adequate fit to the data; however, based on the Akaike information criterion, the fully correlated five-factor model appeared as the most appropriate to measure POC in physical activity. The invariance/equivalence was also confirmed across genders and student status. Four of the five existing factors discriminated pre-action and post-action stages. These data support the validation of the POC questionnaire in physical activity among a French sample. More research is needed to explore the longitudinal properties of this scale.

  4. Establishment of a cervical cancer bio-bank for the Chinese population: from project-based sample collection to routine management.

    PubMed

    Yang, Ru; Li, Xiong; Zhou, Hang; Jia, Yao; Zhou, Jin; Huang, Kecheng; Tang, Fangxu; Hu, Ting; Shen, Jian; Chen, Zhilan; Wang, Shaoshuai; Sun, Haiying; Guo, Lili; Wang, Lin; Wang, Hui; Ma, Ding; Li, Shuang

    2015-08-01

    There is an increasing need for the establishment of a cervical cancer bio-bank that will facilitate both clinical and basic research. The cervical cancer bio-bank was first established in January 1999 and included two stages. First, a GWAS-based sample collection was conducted with special emphasis on the diagnosis and the retrieval of the corresponding bio-specimens, especially blood samples. Second, clinical data and their corresponding bio-specimens were routinely collected and handled. Notably, these bio-specimens also included samples from Wufeng Tujia Autonomous County, which has the highest incidence of cervical cancer in China. The specimens were collected from patients with cervical cancer and those with cervical intraepithelial neoplasia, while the control samples were collected from normal individuals. With special emphasis on clinical data and blood samples for the GWAS analysis, the collection of other bio-specimens was slow, and the pairing of specimens and clinical data was poor during the first stage. However, in the second stage, the pairing of the clinical data and its corresponding bio-specimens improved. At present, the samples procured and preserved in the bio-bank cover most regions of China and different ethnic groups for both the normal controls and cervical cancer patients of different pathological categories. This bio-bank of cervical cancer specimens from the Chinese population will greatly promote the studies of cervical cancer in China.

  5. 78 FR 79009 - Proposed Information Collection; Radiation Sampling and Exposure Records (Pertains to Underground...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-12-27

    ...The Department of Labor, as part of its continuing effort to reduce paperwork and respondent burden, conducts a pre-clearance consultation program to provide the general public and Federal agencies with an opportunity to comment on proposed and continuing collections of information in accordance with the Paperwork Reduction Act of 1995, 44 U.S.C. 3506(c)(2)(A). This program helps to assure that requested data can be provided in the desired format, reporting burden (time and financial resources) is minimized, collection instruments are clearly understood, and the impact of collection requirements on respondents can be properly assessed. Currently, the Mine Safety and Health Administration (MSHA) is soliciting comments concerning the proposed information collection for updating Radiation Sampling and Exposure Records.

  6. NHEXAS PHASE I ARIZONA STUDY--STANDARD OPERATING PROCEDURE FOR FIELD COLLECTION OF INDOOR FLOOR SAMPLES AND POST FIELD SAMPLE HANDLING (UA-F-7.1)

    EPA Science Inventory

    The purpose of this SOP is to establish a uniform procedure for the collection of indoor floor dust samples in the field. This procedure was followed to ensure consistent data retrieval of dust samples during the Arizona NHEXAS project and the "Border" study. Keywords: field; va...

  7. Preliminary Validation of a German Version of the Sexual Complaints Screener for Women in a Female Population Sample.

    PubMed

    Burri, Andrea; Porst, Hartmut

    2018-06-01

    To date, neither the original English nor any of the translated versions of the Sexual Complaints Screener for Women (SCS-W) have been tested for their psychometric properties. To evaluate the validity and utility of the German version of the SCS-W by assessing content, convergent, and discriminant validity. A population sample of 309 women (mean age = 26.9 years) completed the online survey and had matching data available on the SCS-W and the Female Sexual Function Index (FSFI). Spearman bivariate correlations between the SCS-W and FSFI domain scores and exploratory factor analysis with principal component analysis were conducted. Convergent validity was excellent for the domain of orgasm, good for satisfaction, dyspareunia, and the total questionnaire score, and acceptable for desire, lubrication, arousal, and vaginismus. Discriminant validity was present for all domains apart from arousal, lubrication, and vaginismus. Varimax rotation suggested an 8-factor model was the most robust. This brief screener seems suitable to provide a brief overview of female patients' sexual problems in a clinical setting. This is the 1st study to assess the psychometric properties of the German version of the SCS-W. However, available information on the psychometric properties of the German SCS-W was limited because the validity of the screener could not be counterchecked against a clinical diagnosis of female sexual dysfunction. Our results provide preliminary evidence of good validity of the German version of the SCS-W. Overall, the SCS-W can offer support for clinicians who are less familiar with sexual medicine and who might not routinely discuss sexual issues with their patients. Burri A, Porst H. Preliminary Validation of a German Version of the Sexual Complaints Screener for Women in a Female Population Sample. Sex Med 2018;6:123-130. Copyright © 2018 The Authors. Published by Elsevier Inc. All rights reserved.

  8. Trace gas measurements from whole air samples collected over the Antarctic continent

    NASA Technical Reports Server (NTRS)

    Heidt, L. E.; Vedder, J. F.; Pollock, Walter H.; Henry, Bruce E.; Lueb, Richard A.

    1988-01-01

    Whole air samples collected aboard the NASA DC-8 and ER-2 aircraft as part of the Airborne Antarctic Ozone Experiment (AAOE) were analyzed in a field laboratory set up at Punta Arenas, Chile, in August and September, 1987. Mixing ratios obtained from gas chromatographic analyses of these samples are presented for N2O, CFCl3, CFCl2, C2F3Cl3, CH3CCl3, CH4, and CO. Variations in the mixing ratios of these gases along the individual flight paths of the aircraft are used as tracers to indicate the history of air masses over and near the Antarctic continent.

  9. Collecting Comet Samples by ER-2 Aircraft: Cosmic Dust Collection During the Draconid Meteor Shower in October 2012

    NASA Technical Reports Server (NTRS)

    Bastien, Ron; Burkett, P. J.; Rodriquez, M.; Frank, D.; Gonzalez, C.; Robinson, G.-A.; Zolensky, M.; Brown, P.; Campbell-Brown, M.; Broce, S.; hide

    2014-01-01

    Many tons of dust grains, including samples of asteroids and comets, fall from space into the Earth's atmosphere each day. NASA periodically collects some of these particles from the Earth's stratosphere using sticky collectors mounted on NASA's high-flying aircraft. Sometimes, especially when the Earth experiences a known meteor shower, a special opportunity is presented to associate cosmic dust particles with a known source. NASA JSC's Cosmic Dust Collection Program has made special attempts to collect dust from particular meteor showers and asteroid families when flights can be planned well in advance. However, it has rarely been possible to make collections on very short notice. In 2012, the Draconid meteor shower presented that opportunity. The Draconid meteor shower, originating from Comet 21P/Giacobini-Zinner, has produced both outbursts and storms several times during the last century, but the 2012 event was not predicted to be much of a show. Because of these predictions, the Cosmic Dust team had not targeted a stratospheric collection effort for the Draconids, despite the fact that they have one of the slowest atmospheric entry velocities (23 km/s) of any comet shower, and thus offer significant possibilities of successful dust capture. However, radar measurements obtained by the Canadian Meteor Orbit Radar during the 2012 Draconids shower indicated a meteor storm did occur October 8 with a peak at 16:38 (+/-5 min) UTC for a total duration of approximately 2 hours.

  10. CTEPP STANDARD OPERATING PROCEDURE FOR COLLECTION OF DISLODGEABLE RESIDUES -- PUF ROLLER SAMPLES FOR PERSISTENT ORGANIC POLLUTANTS (SOP-2.18)

    EPA Science Inventory

    This SOP describes the method to collect transferable residues from indoor floor surfaces. The sampling procedures described are applicable to bare floors or covered floor surfaces, e.g., carpeting and vinyl flooring. The samples will be collected only in the day care centers o...

  11. Validity of CBCL-derived PTSD and dissociation scales: further evidence in a sample of neglected children and adolescents.

    PubMed

    Milot, Tristan; Plamondon, André; Ethier, Louise S; Lemelin, Jean-Pascal; St-Laurent, Diane; Rousseau, Michel

    2013-05-01

    There is growing evidence that child neglect is an important risk factor for posttraumatic stress disorder (PTSD) and dissociation. Considering that the Child Behavior Checklist (CBCL) is a widely used measure, the possibility of using validated CBCL-derived trauma symptoms scales could be particularly useful to better understand how trauma symptoms develop among neglected children and adolescents. This study examined the factor structure of three CBCL-derived measures of PTSD and dissociation (namely, PTSD scale, Dissociation scale, and PTSD/Dissociation scale) in a sample of 239 neglected children and adolescents aged 6 to 18 years using the latest version of CBCL (CBCL 6-18). Evidence of convergent validity of these scales was also examined for participants aged 12 and under using two well-validated measures of PTSD and Dissociation: the Trauma Symptoms Checklist for Young Children and the Child Dissociation Checklist. Findings suggest that CBCL-derived measures of trauma symptoms, especially PTSD and Dissociations scales, may be of heuristic value in the study of trauma symptomatology in neglected samples. Factor structure and evidence of convergent validity were supported for these two scales. Results also provide further support to the well-established assumption that PTSD and dissociation are two related but different constructs.

  12. Reliability and validity of the Adolescent Stress Questionnaire in a sample of European adolescents - the HELENA study

    PubMed Central

    2011-01-01

    Background Since stress is hypothesized to play a role in the etiology of obesity during adolescence, research on associations between adolescent stress and obesity-related parameters and behaviours is essential. Due to lack of a well-established recent stress checklist for use in European adolescents, the study investigated the reliability and validity of the Adolescent Stress Questionnaire (ASQ) for assessing perceived stress in European adolescents. Methods The ASQ was translated into the languages of the participating cities (Ghent, Stockholm, Vienna, Zaragoza, Pecs and Athens) and was implemented within the HELENA cross-sectional study. A total of 1140 European adolescents provided a valid ASQ, comprising 10 component scales, used for internal reliability (Cronbach α) and construct validity (confirmatory factor analysis or CFA). Contributions of socio-demographic (gender, age, pubertal stage, socio-economic status) characteristics to the ASQ score variances were investigated. Two-hundred adolescents also provided valid saliva samples for cortisol analysis to compare with the ASQ scores (criterion validity). Test-retest reliability was investigated using two ASQ assessments from 37 adolescents. Results Cronbach α-values of the ASQ scales (0.57 to 0.88) demonstrated a moderate internal reliability of the ASQ, and intraclass correlation coefficients (0.45 to 0.84) established an insufficient test-retest reliability of the ASQ. The adolescents' gender (girls had higher stress scores than boys) and pubertal stage (those in a post-pubertal development had higher stress scores than others) significantly contributed to the variance in ASQ scores, while their age and socio-economic status did not. CFA results showed that the original scale construct fitted moderately with the data in our European adolescent population. Only in boys, four out of 10 ASQ scale scores were a significant positive predictor for baseline wake-up salivary cortisol, suggesting a rather poor

  13. Application of the CometChip platform to assess DNA damage in field-collected blood samples from turtles.

    PubMed

    Sykora, Peter; Chiari, Ylenia; Heaton, Andrew; Moreno, Nickolas; Glaberman, Scott; Sobol, Robert W

    2018-05-01

    DNA damage has been linked to genomic instability and the progressive breakdown of cellular and organismal homeostasis, leading to the onset of disease and reduced longevity. Insults to DNA from endogenous sources include base deamination, base hydrolysis, base alkylation, and metabolism-induced oxidative damage that can lead to single-strand and double-strand DNA breaks. Alternatively, exposure to environmental pollutants, radiation or ultra-violet light, can also contribute to exogenously derived DNA damage. We previously validated a novel, high through-put approach to measure levels of DNA damage in cultured mammalian cells. This new CometChip Platform builds on the classical single cell gel electrophoresis or comet methodology used extensively in environmental toxicology and molecular biology. We asked whether the CometChip Platform could be used to measure DNA damage in samples derived from environmental field studies. To this end, we determined that nucleated erythrocytes from multiple species of turtle could be successfully evaluated in the CometChip Platform to quantify levels of DNA damage. In total, we compared levels of DNA damage in 40 animals from two species: the box turtle (Terrapene carolina) and the red-eared slider (Trachemys scripta elegans). Endogenous levels of DNA damage were identical between the two species, yet we did discover some sex-linked differences and changes in DNA damage accumulation. Based on these results, we confirm that the CometChip Platform allows for the measurement of DNA damage in a large number of samples quickly and accurately, and is particularly adaptable to environmental studies using field-collected samples. Environ. Mol. Mutagen. 59:322-333, 2018. © 2018 Wiley Periodicals, Inc. © 2018 Wiley Periodicals, Inc.

  14. Accuracy and Cost-Effectiveness of Cervical Cancer Screening by High-Risk HPV DNA Testing of Self-Collected Vaginal Samples

    PubMed Central

    Balasubramanian, Akhila; Kulasingam, Shalini L.; Baer, Atar; Hughes, James P.; Myers, Evan R.; Mao, Constance; Kiviat, Nancy B.; Koutsky, Laura A.

    2010-01-01

    Objective Estimate the accuracy and cost-effectiveness of cervical cancer screening strategies based on high-risk HPV DNA testing of self-collected vaginal samples. Materials and Methods A subset of 1,665 women (18-50 years of age) participating in a cervical cancer screening study were screened by liquid-based cytology and by high-risk HPV DNA testing of both self-collected vaginal swab samples and clinician-collected cervical samples. Women with positive/abnormal screening test results and a subset of women with negative screening test results were triaged to colposcopy. Based on individual and combined test results, five screening strategies were defined. Estimates of sensitivity and specificity for cervical intraepithelial neoplasia grade 2 or worse were calculated and a Markov model was used to estimate the incremental cost-effectiveness ratios (ICERs) for each strategy. Results Compared to cytology-based screening, high-risk HPV DNA testing of self-collected vaginal samples was more sensitive (68%, 95%CI=58%-78% versus 85%, 95%CI=76%-94%) but less specific (89%, 95%CI=86%-91% versus 73%, 95%CI=67%-79%). A strategy of high-risk HPV DNA testing of self-collected vaginal samples followed by cytology triage of HPV positive women, was comparably sensitive (75%, 95%CI=64%-86%) and specific (88%, 95%CI=85%-92%) to cytology-based screening. In-home self-collection for high-risk HPV DNA detection followed by in-clinic cytology triage had a slightly lower lifetime cost and a slightly higher quality-adjusted life expectancy than did cytology-based screening (ICER of triennial screening compared to no screening was $9,871/QALY and $12,878/QALY, respectively). Conclusions Triennial screening by high-risk HPV DNA testing of in-home, self-collected vaginal samples followed by in-clinic cytology triage was cost-effective. PMID:20592553

  15. Hexabromocyclododecane determination in seafood samples collected from Japanese coastal areas.

    PubMed

    Nakagawa, R; Murata, S; Ashizuka, Y; Shintani, Y; Hori, T; Tsutsumi, T

    2010-09-01

    The levels of three hexabromocyclododecane (HBCD) isomers and ΣHBCDs in 54 wild and 11 farmed seafood samples collected from four regions of Japan were determined by LC/MS/MS. For the fish classified as Anguilliformes, Perciformes, Clupeiformes and farmed Salmoniformes, the medians (ranges) of ΣHBCDs are 2.09 (0.05-36.9), 0.75 (ND-26.2), 0.12 (0.09-77.3) and 1.29 (1.09-1.34) ng g(-1)ww, respectively. However, HBCDs were not detected in samples classified as Crustacea, Mollusca, Pleuronectiformes and Scorpaeniformes, or if detected, the levels were very low. The rank correlation between ΣHBCDs (or α-HBCD) and fat content could not be found except for the Japanese sea bass of the Tohoku region. In HBCD isomer profiles, for fish samples above 20 ng g(-1)ww, the trend was found that γ-HBCD was predominant, which suggests the influence of discharge from a nearby industrial plant. In the other wild fish and the farmed fish samples, on the other hand, α-HBCD was mostly predominant, which suggests biomagnification via the food chain. Additionally, to assess the risk to human health, based on the determined HBCD median concentrations for Anguilliformes, farmed Salmoniformes and Perciformes, the daily intake of HBCDs from fish by an average Japanese adult was tentatively calculated to be 3.7, 2.3 and 1.3 ng (kg body weight)(-1) d(-1), respectively. Copyright © 2010 Elsevier Ltd. All rights reserved.

  16. Leveraging biospecimen resources for discovery or validation of markers for early cancer detection.

    PubMed

    Schully, Sheri D; Carrick, Danielle M; Mechanic, Leah E; Srivastava, Sudhir; Anderson, Garnet L; Baron, John A; Berg, Christine D; Cullen, Jennifer; Diamandis, Eleftherios P; Doria-Rose, V Paul; Goddard, Katrina A B; Hankinson, Susan E; Kushi, Lawrence H; Larson, Eric B; McShane, Lisa M; Schilsky, Richard L; Shak, Steven; Skates, Steven J; Urban, Nicole; Kramer, Barnett S; Khoury, Muin J; Ransohoff, David F

    2015-04-01

    Validation of early detection cancer biomarkers has proven to be disappointing when initial promising claims have often not been reproducible in diagnostic samples or did not extend to prediagnostic samples. The previously reported lack of rigorous internal validity (systematic differences between compared groups) and external validity (lack of generalizability beyond compared groups) may be effectively addressed by utilizing blood specimens and data collected within well-conducted cohort studies. Cohort studies with prediagnostic specimens (eg, blood specimens collected prior to development of clinical symptoms) and clinical data have recently been used to assess the validity of some early detection biomarkers. With this background, the Division of Cancer Control and Population Sciences (DCCPS) and the Division of Cancer Prevention (DCP) of the National Cancer Institute (NCI) held a joint workshop in August 2013. The goal was to advance early detection cancer research by considering how the infrastructure of cohort studies that already exist or are being developed might be leveraged to include appropriate blood specimens, including prediagnostic specimens, ideally collected at periodic intervals, along with clinical data about symptom status and cancer diagnosis. Three overarching recommendations emerged from the discussions: 1) facilitate sharing of existing specimens and data, 2) encourage collaboration among scientists developing biomarkers and those conducting observational cohort studies or managing healthcare systems with cohorts followed over time, and 3) conduct pilot projects that identify and address key logistic and feasibility issues regarding how appropriate specimens and clinical data might be collected at reasonable effort and cost within existing or future cohorts. © Published by Oxford University Press 2015.

  17. Leveraging Biospecimen Resources for Discovery or Validation of Markers for Early Cancer Detection

    PubMed Central

    Carrick, Danielle M.; Mechanic, Leah E.; Srivastava, Sudhir; Anderson, Garnet L.; Baron, John A.; Berg, Christine D.; Cullen, Jennifer; Diamandis, Eleftherios P.; Doria-Rose, V. Paul; Goddard, Katrina A. B.; Hankinson, Susan E.; Kushi, Lawrence H.; Larson, Eric B.; McShane, Lisa M.; Schilsky, Richard L.; Shak, Steven; Skates, Steven J.; Urban, Nicole; Kramer, Barnett S.; Khoury, Muin J.; Ransohoff, David F.

    2015-01-01

    Validation of early detection cancer biomarkers has proven to be disappointing when initial promising claims have often not been reproducible in diagnostic samples or did not extend to prediagnostic samples. The previously reported lack of rigorous internal validity (systematic differences between compared groups) and external validity (lack of generalizability beyond compared groups) may be effectively addressed by utilizing blood specimens and data collected within well-conducted cohort studies. Cohort studies with prediagnostic specimens (eg, blood specimens collected prior to development of clinical symptoms) and clinical data have recently been used to assess the validity of some early detection biomarkers. With this background, the Division of Cancer Control and Population Sciences (DCCPS) and the Division of Cancer Prevention (DCP) of the National Cancer Institute (NCI) held a joint workshop in August 2013. The goal was to advance early detection cancer research by considering how the infrastructure of cohort studies that already exist or are being developed might be leveraged to include appropriate blood specimens, including prediagnostic specimens, ideally collected at periodic intervals, along with clinical data about symptom status and cancer diagnosis. Three overarching recommendations emerged from the discussions: 1) facilitate sharing of existing specimens and data, 2) encourage collaboration among scientists developing biomarkers and those conducting observational cohort studies or managing healthcare systems with cohorts followed over time, and 3) conduct pilot projects that identify and address key logistic and feasibility issues regarding how appropriate specimens and clinical data might be collected at reasonable effort and cost within existing or future cohorts. PMID:25688116

  18. Validated low-volume aldosterone immunoassay tailored to GCLP-compliant investigations in small sample volumes.

    PubMed

    Schaefer, J; Burckhardt, B B; Tins, J; Bartel, A; Laeer, S

    2017-12-01

    Heart failure is well investigated in adults, but data in children is lacking. To overcome this shortage of reliable data, appropriate bioanalytical assays are required. Development and validation of a bioanalytical assay for the determination of aldosterone concentrations in small sample volumes applicable to clinical studies under Good Clinical Laboratory Practice. An immunoassay was developed based on a commercially available enzyme-linked immunosorbent assay and validated according to current bioanalytical guidelines of the EMA and FDA. The assay (range 31.3-1000 pg/mL [86.9-2775 pmol/L]) is characterized by a between-run accuracy from - 3.8% to - 0.8% and a between-run imprecision ranging from 4.9% to 8.9% (coefficient of variation). For within-run accuracy, the relative error was between - 11.1% and + 9.0%, while within-run imprecision ranged from 1.2% to 11.8% (CV). For parallelism and dilutional linearity, the relative error of back-calculated concentrations varied from - 14.1% to + 8.4% and from - 7.4% to + 10.5%, respectively. The immunoassay is compliant with the bioanalytical guidelines of the EMA and FDA and allows accurate and precise aldosterone determinations. As the assay can run low-volume samples, it is especially valuable for pediatric investigations.

  19. Analysis of Dust Samples Collected from an In-Service Interim Storage System at the Maine Yankee Nuclear Site.

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Bryan, Charles R.; Enos, David

    In July, 2016, the Electric Power Research Institute and industry partners performed a field test at the Maine Yankee Nuclear Site, located near Wiscasset, Maine. The primary goal of the field test was to evaluate the use of robots in surveying the surface of an in-service interim storage canister within an overpack; however, as part of the demonstration, dust and soluble salt samples were collected from horizontal surfaces within the interim storage system. The storage system is a vertical system made by NAC International, consisting of a steel-lined concrete overpack containing a 304 stainless steel (SS) welded storage canister. Themore » canister did not contain spent fuel but rather greater-than-class-C waste, which did not generate significant heat, limiting airflow through the storage system. The surfaces that were sampled for deposits included the top of the shield plug, the side of the canister, and a shelf at the bottom of the overpack, just below the level of the pillar on which the canister sits. The samples were sent to Sandia National Laboratories for analysis. This report summarizes the results of those analyses. Because the primary goal of the field test was to evaluate the use of robots in surveying the surface of the canister within the overpack, collection of dust samples was carried out in a qualitative fashion, using paper filters and sponges as the sampling media. The sampling focused mostly on determining the composition of soluble salts present in the dust. It was anticipated that a wet substrate would more effectively extract soluble salts from the surface that was sampled, so both the sponges and the filter paper were wetted prior to being applied to the surface of the metal. Sampling was accomplished by simply pressing the damp substrate against the metal surface for two minutes, and then removing it. It is unlikely that the sampling method quantitatively collected dust or salts from the metal surface; however, both substrates did

  20. Water-quality assessment of south-central Texas : comparison of water quality in surface-water samples collected manually and by automated samplers

    USGS Publications Warehouse

    Ging, Patricia B.

    1999-01-01

    Surface-water sampling protocols of the U.S. Geological Survey National Water-Quality Assessment (NAWQA) Program specify samples for most properties and constituents to be collected manually in equal-width increments across a stream channel and composited for analysis. Single-point sampling with an automated sampler (autosampler) during storms was proposed in the upper part of the South-Central Texas NAWQA study unit, raising the question of whether property and constituent concentrations from automatically collected samples differ significantly from those in samples collected manually. Statistical (Wilcoxon signed-rank test) analyses of 3 to 16 paired concentrations for each of 26 properties and constituents from water samples collected using both methods at eight sites in the upper part of the study unit indicated that there were no significant differences in concentrations for dissolved constituents, other than calcium and organic carbon.

  1. Anopheles sinensis mosquito insecticide resistance: comparison of three mosquito sample collection and preparation methods and mosquito age in resistance measurements.

    PubMed

    Xu, Tielong; Zhong, Daibin; Tang, Linhua; Chang, Xuelian; Fu, Fengyang; Yan, Guiyun; Zheng, Bin

    2014-01-28

    Insecticide resistance monitoring in malaria mosquitoes is essential for guiding the rational use of insecticides in vector control programs. Resistance bioassay is the first step for insecticide monitoring and it lays an important foundation for molecular examination of resistance mechanisms. In the literature, various mosquito sample collection and preparation methods have been used, but how mosquito sample collection and preparation methods affect insecticide susceptibility bioassay results is largely unknown. The objectives of this study were to determine whether mosquito sample collection and preparation methods affected bioassay results, which may cause incorrect classification of mosquito resistance status. The study was conducted in Anopheles sinensis mosquitoes in two study sites in central China. Three mosquito sample collection and preparation methods were compared for insecticide susceptibility, kdr frequencies and metabolic enzyme activities: 1) adult mosquitoes collected from the field; 2) F1 adults from field collected, blood-fed mosquitoes; and 3) adult mosquitoes reared from field collected larvae. Mosquito sample collection and preparation methods significantly affected mortality rates in the standard WHO tube resistance bioassay. Mortality rate of field-collected female adults was 10-15% higher than in mosquitoes reared from field-collected larvae and F1 adults from field collected blood-fed females. This pattern was consistent in mosquitoes from the two study sites. High kdr mutation frequency (85-95%) with L1014F allele as the predominant mutation was found in our study populations. Field-collected female adults consistently exhibited the highest monooxygenase and GST activities. The higher mortality rate observed in the field-collected female mosquitoes may have been caused by a mixture of mosquitoes of different ages, as older mosquitoes were more susceptible to deltamethrin than younger mosquitoes. Female adults reared from field-collected

  2. Validation of the Chronic Pain Acceptance Questionnaire-8 in an Australian pain clinic sample.

    PubMed

    Baranoff, John; Hanrahan, Stephanie J; Kapur, Dilip; Connor, Jason P

    2014-02-01

    Recently, an 8-item short-form version of the Chronic Pain Acceptance Questionnaire (CPAQ-8) was developed predominantly in an internet sample. Further investigation of the factor structure in a multidisciplinary pain clinic sample is required. Investigation of the concurrent validity of the CPAQ-8 after accounting for the effects of variables commonly measured in the pain clinic setting is also necessary. This study examines the factor structure and concurrent validity of the CPAQ-8 in a sample of treatment-seeking patients who attended a multidisciplinary pain clinic. Participants were 334 patients who attended an Australian multidisciplinary pain service. Participants completed the CPAQ, a demographic questionnaire, and measures of patient adjustment and functioning. Confirmatory factor analysis identified a two-factor 8-item model consisting of Activity Engagement and Pain Willingness factors (SRMR = 0.039, RMSEA = 0.063, CFI = 0.973, TLI = 0.960) was superior to both the CPAQ and CPAQ with an item removed. The CPAQ and CPAQ-8 total scores were highly correlated (r = 0.93). After accounting for pain intensity, the CPAQ-8 was a significant predictor of depression, anxiety, stress, and disability. The subscales of the CPAQ-8 were both unique contributors to depression and disability in regression analyses, after accounting for pain intensity and kinesiophobia, and after accounting for pain intensity and catastrophizing. The CPAQ-8 has a sound factor structure and similar psychometric properties to the CPAQ; it may have clinical utility as a measure of pain acceptance in treatment-seeking, chronic pain patients.

  3. Changes in sample collection and analytical techniques and effects on retrospective comparability of low-level concentrations of trace elements in ground water

    USGS Publications Warehouse

    Ivahnenko, T.; Szabo, Z.; Gibs, J.

    2001-01-01

    Ground-water sampling techniques were modified to reduce random low-level contamination during collection of filtered water samples for determination of trace-element concentrations. The modified sampling techniques were first used in New Jersey by the US Geological Survey in 1994 along with inductively coupled plasma-mass spectrometry (ICP-MS) analysis to determine the concentrations of 18 trace elements at the one microgram-per-liter (μg/L) level in the oxic water of the unconfined sand and gravel Kirkwood-Cohansey aquifer system. The revised technique tested included a combination of the following: collection of samples (1) with flow rates of about 2L per minute, (2) through acid-washed single-use disposable tubing and (3) a single-use disposable 0.45-μm pore size capsule filter, (4) contained within portable glove boxes, (5) in a dedicated clean sampling van, (6) only after turbidity stabilized at values less than 2 nephelometric turbidity units (NTU), when possible. Quality-assurance data, obtained from equipment blanks and split samples, indicated that trace element concentrations, with the exception of iron, chromium, aluminum, and zinc, measured in the samples collected in 1994 were not subject to random contamination at 1μg/L.Results from samples collected in 1994 were compared to those from samples collected in 1991 from the same 12 PVC-cased observation wells using the available sampling and analytical techniques at that time. Concentrations of copper, lead, manganese and zinc were statistically significantly lower in samples collected in 1994 than in 1991. Sampling techniques used in 1994 likely provided trace-element data that represented concentrations in the aquifer with less bias than data from 1991 when samples were collected without the same degree of attention to sample handling.

  4. Monitoring of uranium concentrations in water samples collected near potentially hazardous objects in North-West Tajikistan.

    PubMed

    Zoriy, P; Schläger, M; Murtazaev, K; Pillath, J; Zoriy, M; Heuel-Fabianek, B

    2018-01-01

    The water contamination near ecologically problematic objects was investigated between 2009 and 2014 in North-West Tajikistan as a part of a joint project between Forschungszentrum Jülich and Khujand State University. The main part of this work was the determination of uranium in water samples collected near the Degmay tailings dump, the Taboshar pit lake and the Syr Darya river. More than 130 water samples were collected and analyzed to monitor the uranium concentration near the investigated areas. Two different mass spectrometers and an ion chromatograph were used for element concentration measurements. Based on the results obtained, the uranium influence of the Degmay tailings on the rivers Khoja-Bakyrgan-Say and Syr Darya and surrounding water was not found. The uranium concentration in water samples was monitored for a lengthy period at seven locations Great differences in the uranium concentration in waters collected in 2010, 2011, 2012, 2013 for each location were not observed. Drinking water samples from the region of North-West Tajikistan were analyzed and compared with the World Health Organization's guidelines. Seven out of nine drinking water samples near Taboshar exceeded the WHO guideline value for uranium concentrations (30 μg/L). The average uranium concentration of water samples from Syr Darya for the period from 2009 to 2014 was determined to be 20.1 (±5.2) μg/L. The uranium contamination of the Syr Darya was determined from the western border to the eastern border and the results are shown in this paper. Copyright © 2017 Elsevier Ltd. All rights reserved.

  5. Cross-Cultural Validation of the Basic Psychological Needs in Physical Education Scale between Portugal and Brazil Samples.

    PubMed

    Cid, Luis; Lettnin, Carla; Stobäus, Claus; Monteiro, Diogo; Davoglio, Tárcia; Moutão, João

    2016-02-19

    The main propose of this study is the cross-cultural validation of the Basic Psychological Needs in Physical Education Scale among Portugal and Brazil samples, through the study of measurement model invariance. Participated in this study, two independent samples, one with 616 Portuguese students, of the 2nd and 3rd basic grade of public school, aged between 9 and 18 years old and another with 450 Brazilian students, from 1st, 2nd and 3rd middle grade of public and private school, aged between 14 and 18 years old. The results support the suitability of the model (three factors, each one with four items), showing an adequate fit to the data in each sample (Portugal: χ2 = 203.8, p = .001, df = 51, SRMR = .062, NNFI = .926, CFI = .943, RMSEA = .070, RMSEA 90% IC = .060-.080; Brazil: χ2 = 173.7, p = .001, df = 51, SRMR = .052, NNFI = .940, CFI = .954, RMSEA = .073, RMSEA 90% IC = .061-.085), as well valid cross-cultural invariance among Portuguese e Brazilian samples (∆CFI ≤ .01). Those findings allow us to conclude that scale can be used to measure the basic psychological needs in physical education in Portugal and in Brazil.

  6. SPRUCE Deep Peat Heat (DPH) Metagenomes for Peat Samples Collected June 2015

    DOE Data Explorer

    Klumber, Laurel A. [Oak Ridge National Laboratory, U.S. Department of Energy, Oak Ridge, Tennessee, U.S.A.; Yang, Zamin K. [Oak Ridge National Laboratory, U.S. Department of Energy, Oak Ridge, Tennessee, U.S.A.; Schadt, Christopher W. [Oak Ridge National Laboratory, U.S. Department of Energy, Oak Ridge, Tennessee, U.S.A.

    2015-01-01

    This data set provides links to the results of metagenomic analyses of 38 peat core samples collected on 16 June 2015 from SPRUCE experiment treatment plots after approximately one year of belowground heating. These metagenomes are archived in the U.S. Department of Energy Joint Genome Institute (DOE JGI) Integrated Microbial Genomes (IMG) system and are available at the accession numbers provided in the accompanying inventory file.

  7. Monitoring Phytophthora ramorum and P. kernoviae in soil and rainwater samples collected at two sites on a cornish estate

    Treesearch

    David Lockley; Judith Turner; Gillian Humphries; Phil Jennings

    2008-01-01

    Soil samples were collected from quadrats marked out below the canopies of two rhododendrons, one infected by Phytophthora ramorum (Site 1) and the other (Site 2) infected by Phytophthora kernoviae and P. ramorum. Rainwater was collected in high-level and low level traps. Soil and rainwater were sampled at...

  8. Integrated chemical/biochemical sample collection, pre-concentration, and analysis on a digital microfluidic lab-on-a-chip platform

    NASA Astrophysics Data System (ADS)

    Fair, Richard B.; Khlystov, A.; Srinivasan, Vijay; Pamula, Vamsee K.; Weaver, Kathryn N.

    2004-12-01

    An ideal on-site chemical/biochemical analysis system must be inexpensive, sensitive, fully automated and integrated, reliable, and compatible with a broad range of samples. The advent of digital microfluidic lab-on-a-chip (LoC) technology offers such a detection system due to the advantages in portability, reduction of the volumes of the sample and reagents, faster analysis times, increased automation, low power consumption, compatibility with mass manufacturing, and high throughput. We describe progress towards integrating sample collection onto a digital microfluidic LoC that is a component of a cascade impactor device. The sample collection is performed by impacting airborne particles directly onto the surface of the chip. After the collection phase, the surface of the chip is washed with a micro-droplet of solvent. The droplet will be digitally directed across the impaction surface, dissolving sample constituents. Because of the very small droplet volume used for extraction of the sample from a wide colection area, the resulting solution is realatively concentrated and the analytes can be detected after a very short sampling time (1 min) due to such pre-concentration. After the washing phase, the droplet is mixed with specific reagents that produce colored reaction products. The concentration of the analyte is quantitatively determined by measuring absorption at target wavelengths using a simple light emitting diode and photodiode setup. Specific applications include automatic measurements of major inorganic ions in aerosols, such as sulfate, nitrate and ammonium, with a time resolution of 1 min and a detection limit of 30 nm/m3. We have already demonstrated the detection and quantification of nitroaromatic explosives without integrating the sample collection. Other applications being developed include airborne bioagent detection.

  9. Field guide for collecting samples for analysis of volatile organic compounds in stream water for the National Water-Quality Assessment Program

    USGS Publications Warehouse

    Shelton, Larry R.

    1997-01-01

    For many years, stream samples for analysis of volatile organic compounds have been collected without specific guidelines or a sampler designed to avoid analyte loss. In 1996, the U.S. Geological Survey's National Water-Quality Assessment Program began aggressively monitoring urban stream-water for volatile organic compounds. To assure representative samples and consistency in collection procedures, a specific sampler was designed to collect samples for analysis of volatile organic compounds in stream water. This sampler, and the collection procedures, were tested in the laboratory and in the field for compound loss, contamination, sample reproducibility, and functional capabilities. This report describes that sampler and its use, and outlines field procedures specifically designed to provide contaminant-free, reproducible volatile organic compound data from stream-water samples. These guidelines and the equipment described represent a significant change in U.S. Geological Survey instructions for collecting and processing stream-water samples for analysis of volatile organic compounds. They are intended to produce data that are both defensible and interpretable, particularly for concentrations below the microgram-per-liter level. The guidelines also contain detailed recommendations for quality-control samples.

  10. Preliminary validation of the Yale Food Addiction Scale.

    PubMed

    Gearhardt, Ashley N; Corbin, William R; Brownell, Kelly D

    2009-04-01

    Previous research has found similarities between addiction to psychoactive substances and excessive food consumption. Further exploration is needed to evaluate the concept of "food addiction," as there is currently a lack of psychometrically validated measurement tools in this area. The current study represents a preliminary exploration of the Yale Food Addiction Scale (YFAS), designed to identify those exhibiting signs of addiction towards certain types of foods (e.g., high fat and high sugar). Survey data were collected from 353 respondents from a stratified random sample of young adults. In addition to the YFAS, the survey assessed eating pathology, alcohol consumption and other health behaviors. The YFAS exhibited adequate internal reliability, and showed good convergent validity with measures of similar constructs and good discriminant validity relative to related but dissimilar constructs. Additionally, the YFAS predicted binge-eating behavior above and beyond existing measures of eating pathology, demonstrating incremental validity. The YFAS is a sound tool for identifying eating patterns that are similar to behaviors seen in classic areas of addiction. Further evaluation of the scale is needed, especially due to a low response rate of 24.5% and a non-clinical sample, but confirmation of the reliability and validity of the scale has the potential to facilitate empirical research on the concept of "food addiction".

  11. 75 FR 79033 - Proposed Extension of Existing Information Collection; Radiation Sampling and Exposure Records...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-12-17

    ...The Department of Labor, as part of its continuing effort to reduce paperwork and respondent burden, conducts a pre-clearance consultation program to provide the general public and Federal agencies with an opportunity to comment on proposed and continuing collections of information in accordance with the Paperwork Reduction Act of 1995 [44 U.S.C. 3506(c)(2)(A)]. This program helps to assure that requested data can be provided in the desired format, reporting burden (time and financial resources) is minimized, collection instruments are clearly understood, and the impact of collection requirements on respondents can be properly assessed. Currently, the Mine Safety and Health Administration (MSHA) is soliciting comments concerning the extension of the information collection for Radiation Sampling and Exposure Records, 30 CFR 57.5037 and 57.5040.

  12. 75 FR 80072 - Proposed Extension of Existing Information Collection; Radiation Sampling and Exposure Records

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-12-21

    ...The Department of Labor, as part of its continuing effort to reduce paperwork and respondent burden, conducts a pre-clearance consultation program to provide the general public and Federal agencies with an opportunity to comment on proposed and continuing collections of information in accordance with the Paperwork Reduction Act of 1995 [44 U.S.C. 3506(c)(2)(A)]. This program helps to assure that requested data can be provided in the desired format, reporting burden (time and financial resources) is minimized, collection instruments are clearly understood, and the impact of collection requirements on respondents can be properly assessed. Currently, the Mine Safety and Health Administration (MSHA) is soliciting comments concerning the extension of the information collection for Radiation Sampling and Exposure Records, 30 CFR 57.5037 and 57.5040.

  13. Reliability and validity of the Spanish Language Wechsler Adult Intelligence Scale (3rd Edition) in a sample of American, urban, Spanish-speaking Hispanics.

    PubMed

    Renteria, Laura; Li, Susan Tinsley; Pliskin, Neil H

    2008-05-01

    The utility of the Spanish WAIS-III was investigated by examining its reliability and validity among 100 Spanish-speaking participants. Results indicated that the internal consistency of the subtests was satisfactory, but inadequate for Letter Number Sequencing. Criterion validity was adequate. Convergent and discriminant validity results were generally similar to the North American normative sample. Paired sample t-tests suggested that the WAIS-III may underestimate ability when compared to the criterion measures that were utilized to assess validity. This study provides support for the use of the Spanish WAIS-III in urban Hispanic populations, but also suggests that caution be used when administering specific subtests, due to the nature of the Latin America alphabet and potential test bias.

  14. Destructive testings: dry drilling operations with TruPro system to collect samples in a powder form, from two hulls containing immobilized wastes in a hydraulic binder

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Pombet, Denis; Desnoyers, Yvon; Charters, Grant

    2013-07-01

    The TruPro{sup R} process enables to collect a significant number of samples to characterize radiological materials. This innovative and alternative technique is experimented for the ANDRA quality-control inspection of cemented packages. It proves to be quicker and more prolific than the current methodology. Using classical statistics and geo-statistics approaches, the physical and radiological characteristics of two hulls containing immobilized wastes (sludges or concentrates) in a hydraulic binder are assessed in this paper. The waste homogeneity is also evaluated in comparison to ANDRA criterion. Sensibility to sample size (support effect), presence of extreme values, acceptable deviation rate and minimum number ofmore » data are discussed. The final objectives are to check the homogeneity of the two characterized radwaste packages and also to validate and reinforce this alternative characterization methodology. (authors)« less

  15. K3EDTA Vacuum Tubes Validation for Routine Hematological Testing

    PubMed Central

    Lima-Oliveira, Gabriel; Lippi, Giuseppe; Salvagno, Gian Luca; Montagnana, Martina; Poli, Giovanni; Solero, Giovanni Pietro; Picheth, Geraldo; Guidi, Gian Cesare

    2012-01-01

    Background and Objective. Some in vitro diagnostic devices (e.g, blood collection vacuum tubes and syringes for blood analyses) are not validated before the quality laboratory managers decide to start using or to change the brand. Frequently, the laboratory or hospital managers select the vacuum tubes for blood collection based on cost considerations or on relevance of a brand. The aim of this study was to validate two dry K3EDTA vacuum tubes of different brands for routine hematological testing. Methods. Blood specimens from 100 volunteers in two different K3EDTA vacuum tubes were collected by a single, expert phlebotomist. The routine hematological testing was done on Advia 2120i hematology system. The significance of the differences between samples was assessed by paired Student's t-test after checking for normality. The level of statistical significance was set at P < 0.05. Results and Conclusions. Different brand's tubes evaluated can represent a clinically relevant source of variations only on mean platelet volume (MPV) and platelet distribution width (PDW). Basically, our validation will permit the laboratory or hospital managers to select the brand's vacuum tubes validated according to him/her technical or economical reasons for routine hematological tests. PMID:22888448

  16. The Development and Validation of the Bergen-Yale Sex Addiction Scale With a Large National Sample.

    PubMed

    Andreassen, Cecilie S; Pallesen, Ståle; Griffiths, Mark D; Torsheim, Torbjørn; Sinha, Rajita

    2018-01-01

    The view that problematic excessive sexual behavior ("sex addiction") is a form of behavioral addiction has gained more credence in recent years, but there is still considerable controversy regarding operationalization of the concept. Furthermore, most previous studies have relied on small clinical samples. The present study presents a new method for assessing sex addiction-the Bergen-Yale Sex Addiction Scale (BYSAS)-based on established addiction components (i.e., salience/craving, mood modification, tolerance, withdrawal, conflict/problems, and relapse/loss of control). Using a cross-sectional survey, the BYSAS was administered to a broad national sample of 23,533 Norwegian adults [aged 16-88 years; mean (± SD ) age = 35.8 ± 13.3 years], together with validated measures of the Big Five personality traits, narcissism, self-esteem, and a measure of sexual addictive behavior. Both an exploratory and a confirmatory factor analysis (RMSEA = 0.046, CFI = 0.998, TLI = 0.996) supported a one-factor solution, although a local dependence between two items (Items 1 and 2) was detected. Furthermore, the scale had good internal consistency (Cronbach's α = 0.83). The BYSAS correlated significantly with the reference scale ( r = 0.52), and demonstrated similar patterns of convergent and discriminant validity. The BYSAS was positively related to extroversion, neuroticism, intellect/imagination, and narcissism, and negatively related to conscientiousness, agreeableness, and self-esteem. High scores on the BYSAS were more prevalent among those who were men, single, of younger age, and with higher education. The BYSAS is a brief, and psychometrically reliable and valid measure for assessing sex addiction. However, further validation of the BYSAS is needed in other countries and contexts.

  17. The Development and Validation of the Bergen–Yale Sex Addiction Scale With a Large National Sample

    PubMed Central

    Andreassen, Cecilie S.; Pallesen, Ståle; Griffiths, Mark D.; Torsheim, Torbjørn; Sinha, Rajita

    2018-01-01

    The view that problematic excessive sexual behavior (“sex addiction”) is a form of behavioral addiction has gained more credence in recent years, but there is still considerable controversy regarding operationalization of the concept. Furthermore, most previous studies have relied on small clinical samples. The present study presents a new method for assessing sex addiction—the Bergen–Yale Sex Addiction Scale (BYSAS)—based on established addiction components (i.e., salience/craving, mood modification, tolerance, withdrawal, conflict/problems, and relapse/loss of control). Using a cross-sectional survey, the BYSAS was administered to a broad national sample of 23,533 Norwegian adults [aged 16–88 years; mean (± SD) age = 35.8 ± 13.3 years], together with validated measures of the Big Five personality traits, narcissism, self-esteem, and a measure of sexual addictive behavior. Both an exploratory and a confirmatory factor analysis (RMSEA = 0.046, CFI = 0.998, TLI = 0.996) supported a one-factor solution, although a local dependence between two items (Items 1 and 2) was detected. Furthermore, the scale had good internal consistency (Cronbach's α = 0.83). The BYSAS correlated significantly with the reference scale (r = 0.52), and demonstrated similar patterns of convergent and discriminant validity. The BYSAS was positively related to extroversion, neuroticism, intellect/imagination, and narcissism, and negatively related to conscientiousness, agreeableness, and self-esteem. High scores on the BYSAS were more prevalent among those who were men, single, of younger age, and with higher education. The BYSAS is a brief, and psychometrically reliable and valid measure for assessing sex addiction. However, further validation of the BYSAS is needed in other countries and contexts. PMID:29568277

  18. Validation of the Spanish version of the "Questionnaire on the treatment of approximal and occlusal caries".

    PubMed

    Ruiz, Begoña; Urzúa, Iván; Cabello, Rodrigo; Rodríguez, Gonzalo; Espelid, Ivar

    2013-01-01

    To translate and validate a Spanish version of the "Questionnaire on the treatment of approximal and occlusal caries" as a method of collecting information about treatment decisions on caries management in Chilean primary health care services. The original questionnaire proposed by Espelid et al. was translated into Spanish using the forward-backward translation technique. Subsequently, validation of the Spanish version was undertaken. Data were collected from two separate samples; first, from 132 Spanish-speaking dentists recruited from primary health care services and second, from 21 individuals characterised as cariologists. Internal consistency was evaluated by the generation of Cronbach's alpha, test-retest reliability was evaluated by Cohen's kappa, convergent validity was evaluated by comparing the total scale scores to a global evaluation of treatment trends and discriminant validity was evaluated by investigating the differences in total scale scores between the Spanish-speaking dentist and cariologist samples. Cronbach's alpha indicated an internal consistency of 0.63 for the entire scale. Cohen's kappa correlation coefficient expressed a test-retest reliability of 0.83. Convergent validity determined a Pearson's correlation coefficient of 0.24 (p < 0.01). The comparison of proportions (chi-squared) indicated that discriminant validity was statistically significant (p < 0.01), using a one-tailed test. The Spanish version of the "Questionnaire on the treatment of approximal and occlusal caries" is a valid and reliable instrument for collecting information regarding treatment decisions in cariology. The clinical relevance of this study is to acquire a reliable instrument that allows for the determination of treatment decisions in Spanish-speaking dentists.

  19. Ram-air sample collection device for a chemical warfare agent sensor

    DOEpatents

    Megerle, Clifford A.; Adkins, Douglas R.; Frye-Mason, Gregory C.

    2002-01-01

    In a surface acoustic wave sensor mounted within a body, the sensor having a surface acoustic wave array detector and a micro-fabricated sample preconcentrator exposed on a surface of the body, an apparatus for collecting air for the sensor, comprising a housing operatively arranged to mount atop the body, the housing including a multi-stage channel having an inlet and an outlet, the channel having a first stage having a first height and width proximate the inlet, a second stage having a second lower height and width proximate the micro-fabricated sample preconcentrator, a third stage having a still lower third height and width proximate the surface acoustic wave array detector, and a fourth stage having a fourth height and width proximate the outlet, where the fourth height and width are substantially the same as the first height and width.

  20. Development and validation of a real-time PCR assay for the detection of Toxoplasma gondii DNA in animal and meat samples.

    PubMed

    Marino, Anna Maria Fausta; Percipalle, Maurizio; Giunta, Renato Paolo; Salvaggio, Antonio; Caracappa, Giulia; Alfonzetti, Tiziana; Aparo, Alessandra; Reale, Stefano

    2017-03-01

    We report a rapid and reliable method for the detection of Toxoplasma gondii in meat and animal tissues based on real-time polymerase chain reaction (PCR). Samples were collected from cattle, small ruminants, horses, and pigs raised or imported into Sicily, Italy. All DNA preparations were assayed by real-time PCR tests targeted to a 98-bp long fragment in the AF 529-bp repeat element and to the B1 gene using specific primers. Diagnostic sensitivity (100%), diagnostic specificity (100%), limit of detection (0.01 pg), efficiency (92-109%), and precision (mean coefficient of variation = 0.60%), repeatability (100%), reproducibility (100%), and robustness were evaluated using 240 DNA extracted samples (120 positives and 120 negative as per the OIE nested PCR method) from different matrices. Positive results were confirmed by the repetition of both real-time and nested PCR assays. Our study demonstrates the viability of a reliable, rapid, and specific real-time PCR on a large scale to monitor contamination with Toxoplasma cysts in meat and animal specimens. This validated method can be used for postmortem detection in domestic and wild animals and for food safety purposes.

  1. Aqueous Processing of Atmospheric Organic Particles in Cloud Water Collected via Aircraft Sampling.

    PubMed

    Boone, Eric J; Laskin, Alexander; Laskin, Julia; Wirth, Christopher; Shepson, Paul B; Stirm, Brian H; Pratt, Kerri A

    2015-07-21

    Cloudwater and below-cloud atmospheric particle samples were collected onboard a research aircraft during the Southern Oxidant and Aerosol Study (SOAS) over a forested region of Alabama in June 2013. The organic molecular composition of the samples was studied to gain insights into the aqueous-phase processing of organic compounds within cloud droplets. High resolution mass spectrometry (HRMS) with nanospray desorption electrospray ionization (nano-DESI) and direct infusion electrospray ionization (ESI) were utilized to compare the organic composition of the particle and cloudwater samples, respectively. Isoprene and monoterpene-derived organosulfates and oligomers were identified in both the particles and cloudwater, showing the significant influence of biogenic volatile organic compound oxidation above the forested region. While the average O:C ratios of the organic compounds were similar between the atmospheric particle and cloudwater samples, the chemical composition of these samples was quite different. Specifically, hydrolysis of organosulfates and formation of nitrogen-containing compounds were observed for the cloudwater when compared to the atmospheric particle samples, demonstrating that cloud processing changes the composition of organic aerosol.

  2. Aqueous Processing of Atmospheric Organic Particles in Cloud Water Collected via Aircraft Sampling

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Boone, Eric J.; Laskin, Alexander; Laskin, Julia

    2015-07-21

    Cloud water and below-cloud atmospheric particle samples were collected onboard a research aircraft during the Southern Oxidant and Aerosol Study (SOAS) over a forested region of Alabama in June 2013. The organic molecular composition of the samples was studied to gain insights into the aqueous-phase processing of organic compounds within cloud droplets. High resolution mass spectrometry with nanospray desorption electrospray ionization and direct infusion electrospray ionization were utilized to compare the organic composition of the particle and cloud water samples, respectively. Isoprene and monoterpene-derived organosulfates and oligomers were identified in both the particles and cloud water, showing the significant influencemore » of biogenic volatile organic compound oxidation above the forested region. While the average O:C ratios of the organic compounds were similar between the atmospheric particle and cloud water samples, the chemical composition of these samples was quite different. Specifically, hydrolysis of organosulfates and formation of nitrogen-containing compounds were observed for the cloud water when compared to the atmospheric particle samples, demonstrating that cloud processing changes the composition of organic aerosol.« less

  3. Variability of Organophosphorous Pesticide Metabolite Levels in Spot and 24-hr Urine Samples Collected from Young Children during 1 Week

    PubMed Central

    Kogut, Katherine; Eisen, Ellen A.; Jewell, Nicholas P.; Quirós-Alcalá, Lesliam; Castorina, Rosemary; Chevrier, Jonathan; Holland, Nina T.; Barr, Dana Boyd; Kavanagh-Baird, Geri; Eskenazi, Brenda

    2012-01-01

    Background: Dialkyl phosphate (DAP) metabolites in spot urine samples are frequently used to characterize children’s exposures to organophosphorous (OP) pesticides. However, variable exposure and short biological half-lives of OP pesticides could result in highly variable measurements, leading to exposure misclassification. Objective: We examined within- and between-child variability in DAP metabolites in urine samples collected during 1 week. Methods: We collected spot urine samples over 7 consecutive days from 25 children (3–6 years of age). On two of the days, we collected 24-hr voids. We assessed the reproducibility of urinary DAP metabolite concentrations and evaluated the sensitivity and specificity of spot urine samples as predictors of high (top 20%) or elevated (top 40%) weekly average DAP metabolite concentrations. Results: Within-child variance exceeded between-child variance by a factor of two to eight, depending on metabolite grouping. Although total DAP concentrations in single spot urine samples were moderately to strongly associated with concentrations in same-day 24-hr samples (r ≈ 0.6–0.8, p < 0.01), concentrations in spot samples collected > 1 day apart and in 24-hr samples collected 3 days apart were weakly correlated (r ≈ –0.21 to 0.38). Single spot samples predicted high (top 20%) and elevated (top 40%) full-week average total DAP excretion with only moderate sensitivity (≈ 0.52 and ≈ 0.67, respectively) but relatively high specificity (≈ 0.88 and ≈ 0.78, respectively). Conclusions: The high variability we observed in children’s DAP metabolite concentrations suggests that single-day urine samples provide only a brief snapshot of exposure. Sensitivity analyses suggest that classification of cumulative OP exposure based on spot samples is prone to type 2 classification errors. PMID:23052012

  4. May 2013 Groundwater and Surface Water Sampling at the Rio Blanco, Colorado, Site (Data Validation Package)

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Hutton, Rick

    2013-10-01

    Annual sampling was conducted at the Rio Blanco, Colorado, site for the Long-Term Hydrologic Monitoring Program May 14-16, 2013, to monitor groundwater and surface water for potential radionuclide contamination. Sampling and analyses were conducted as specified in Sampling and Analysis Plan for the U.S. Department of Energy Office of Legacy Management Sites (LMS/PRO/S04351, continually updated). A duplicate sample was collected from location CER #1 Black Sulphur. Samples were analyzed for gamma-emitting radionuclides by high-resolution gamma spectrometry and for tritium using the conventional and enrichment methods.

  5. To mix or not to mix venous blood samples collected in vacuum tubes?

    PubMed

    Parenmark, Anna; Landberg, Eva

    2011-09-08

    There are recommendations to mix venous blood samples by inverting the tubes immediately after venipuncture. Though mixing allows efficient anticoagulation in plasma tubes and fast initiation of coagulation in serum tubes, the effect on laboratory analyses and risk of haemolysis has not been thoroughly evaluated. Venous blood samples were collected by venipuncture in vacuum tubes from 50 patients (10 or 20 patients in each group). Four types of tubes and 18 parameters used in routine clinical chemistry were evaluated. For each patient and tube, three types of mixing strategies were used: instant mixing, no mixing and 5 min of rest followed by mixing. Most analyses did not differ significantly in samples admitted to different mixing strategies. Plasma lactate dehydrogenase and haemolysis index showed a small but significant increase in samples omitted to instant mixing compared to samples without mixing. However, in one out of twenty non-mixed samples, activated partial thromboplastin time was seriously affected. These results indicate that mixing blood samples after venipuncture is not mandatory for all types of tubes. Instant mixing may introduce interference for those analyses susceptible to haemolysis. However, tubes with liquid-based citrate buffer for coagulation testing should be mixed to avoid clotting.

  6. New Empirical Evidence on the Validity and the Reliability of the Early Life Stress Questionnaire in a Polish Sample.

    PubMed

    Sokołowski, Andrzej; Dragan, Wojciech Ł

    2017-01-01

    Background: The Early Life Stress Questionnaire (ELSQ) is widely used to estimate the prevalence of negative events during childhood, including emotional, physical, verbal, sexual abuse, negligence, severe conflicts, separation, parental divorce, substance abuse, poverty, and so forth. Objective: This study presents the psychometric properties of the Polish adaptation of the ELSQ. It also verifies if early life stress (ELS) is a good predictor of psychopathology symptoms during adulthood. Materials and Methods: We analyzed data from two samples. Sample 1 was selected by random quota method from across the country and included 609 participants aged 18-50 years, 306 women (50.2%) and 303 men (49.8%). Sample 2 contained 503 young adults (253 women and 250 men) aged 18-25. Confirmatory and exploratory factor analyses were used to measure ELSQ internal consistency. The validity was based on the relation to psychopathological symptoms and substance misuse. Results: Results showed good internal consistency and validity. Exploratory factor analysis indicates a six-factor structure of the ELSQ. ELS was related to psychopathology in adulthood, including depressive, sociophobic, vegetative as well as pain symptoms. ELSQ score correlated also with alcohol use, but not nicotine dependence. Moreover, ELS was correlated with stress in adulthood. Conclusion: The findings indicate that the Polish version of the ELSQ is a valid and reliable instrument for assessing ELS in the Polish population and may be applied in both clinical and community samples.

  7. Validation of the Narcissistic Admiration and Rivalry Questionnaire Short Scale (NARQ-S) in convenience and representative samples.

    PubMed

    Leckelt, Marius; Wetzel, Eunike; Gerlach, Tanja M; Ackerman, Robert A; Miller, Joshua D; Chopik, William J; Penke, Lars; Geukes, Katharina; Küfner, Albrecht C P; Hutteman, Roos; Richter, David; Renner, Karl-Heinz; Allroggen, Marc; Brecheen, Courtney; Campbell, W Keith; Grossmann, Igor; Back, Mitja D

    2018-01-01

    Due to increased empirical interest in narcissism across the social sciences, there is a need for inventories that can be administered quickly while also reliably measuring both the agentic and antagonistic aspects of grandiose narcissism. In this study, we sought to validate the factor structure, provide representative descriptive data and reliability estimates, assess the reliability across the trait spectrum, and examine the nomological network of the short version of the Narcissistic Admiration and Rivalry Questionnaire (NARQ-S; Back et al., 2013). We used data from a large convenience sample (total N = 11,937) as well as data from a large representative sample (total N = 4,433) that included responses to other narcissism measures as well as related constructs, including the other Dark Triad traits, Big Five personality traits, and self-esteem. Confirmatory factor analysis and item response theory were used to validate the factor structure and estimate the reliability across the latent trait spectrum, respectively. Results suggest that the NARQ-S shows a robust factor structure and is a reliable and valid short measure of the agentic and antagonistic aspects of grandiose narcissism. We also discuss future directions and applications of the NARQ-S as a short and comprehensive measure of grandiose narcissism. (PsycINFO Database Record (c) 2018 APA, all rights reserved).

  8. A Multitrait-Multimethod Analysis of the Construct Validity of Child Anxiety Disorders in a Clinical Sample

    ERIC Educational Resources Information Center

    Langer, David A.; Wood, Jeffrey J.; Bergman, R. Lindsey; Piacentini, John C.

    2010-01-01

    The present study examines the construct validity of separation anxiety disorder (SAD), social phobia (SoP), panic disorder (PD), and generalized anxiety disorder (GAD) in a clinical sample of children. Participants were 174 children, 6 to 17 years old (94 boys) who had undergone a diagnostic evaluation at a university hospital based clinic.…

  9. 78 FR 22889 - Agency Information Collection Activities; Proposed Collection; Comment Request

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-04-17

    ... the data collection plans and draft instruments, email [email protected] or call the HRSA Reports... technology to minimize the information collection burden. Information Collection Request Title: Data... utilize technology and systems for the purpose of collecting, validating and verifying information...

  10. Long-Term Ecological Monitoring Field Sampling Plan for 2007

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    T. Haney

    2007-07-31

    This field sampling plan describes the field investigations planned for the Long-Term Ecological Monitoring Project at the Idaho National Laboratory Site in 2007. This plan and the Quality Assurance Project Plan for Waste Area Groups 1, 2, 3, 4, 5, 6, 7, 10, and Removal Actions constitute the sampling and analysis plan supporting long-term ecological monitoring sampling in 2007. The data collected under this plan will become part of the long-term ecological monitoring data set that is being collected annually. The data will be used t determine the requirements for the subsequent long-term ecological monitoring. This plan guides the 2007more » investigations, including sampling, quality assurance, quality control, analytical procedures, and data management. As such, this plan will help to ensure that the resulting monitoring data will be scientifically valid, defensible, and of known and acceptable quality.« less

  11. Subrandom methods for multidimensional nonuniform sampling.

    PubMed

    Worley, Bradley

    2016-08-01

    Methods of nonuniform sampling that utilize pseudorandom number sequences to select points from a weighted Nyquist grid are commonplace in biomolecular NMR studies, due to the beneficial incoherence introduced by pseudorandom sampling. However, these methods require the specification of a non-arbitrary seed number in order to initialize a pseudorandom number generator. Because the performance of pseudorandom sampling schedules can substantially vary based on seed number, this can complicate the task of routine data collection. Approaches such as jittered sampling and stochastic gap sampling are effective at reducing random seed dependence of nonuniform sampling schedules, but still require the specification of a seed number. This work formalizes the use of subrandom number sequences in nonuniform sampling as a means of seed-independent sampling, and compares the performance of three subrandom methods to their pseudorandom counterparts using commonly applied schedule performance metrics. Reconstruction results using experimental datasets are also provided to validate claims made using these performance metrics. Copyright © 2016 Elsevier Inc. All rights reserved.

  12. Evaluation of a new APTIMA specimen collection and transportation kit for high-risk human papillomavirus E6/E7 messenger RNA in cervical and vaginal samples.

    PubMed

    Chernesky, Max; Jang, Dan; Gilchrist, Jodi; Elit, Laurie; Lytwyn, Alice; Smieja, Marek; Dockter, Janel; Getman, Damon; Reid, Jennifer; Hill, Craig

    2014-06-01

    An APTIMA specimen collection and transportation (SCT) kit was developed by Hologic/Gen-Probe. To compare cervical SCT samples to PreservCyt and SurePath samples and self-collected vaginal samples to physician-collected vaginal and cervical SCT samples. To determine ease and comfort of self-collection with the kit. Each woman (n = 580) self-collected a vaginal SCT, then filled out a questionnaire (n = 563) to determine ease and comfort of self-collection. Colposcopy physicians collected a vaginal SCT and cervical PreservCyt, SCT, and SurePath samples. Samples were tested by APTIMA HPV (AHPV) assay. Agreement between testing of cervical SCT and PreservCyt was 91.1% (κ = 0.82), and that of SurePath samples was 86.7% (κ = 0.72). Agreement of self-collected vaginal SCT to physician-collected SCT was 84.7% (κ = 0.68), and that of self-collected vaginal to cervical SCT was 82.0% (κ = 0.63). For 30 patients with CIN2+, AHPV testing of cervical SCT was 100% sensitive and 59.8% specific compared with PreservCyt (96.6% and 66.2%) and SurePath (93.3% and 70.9%). Vaginal SCT sensitivity was 86.7% for self-collection and 80.0% for physician collection. Most patients found that vaginal self-collection was easy, 5.3% reported some difficulty, and 87.6% expressed no discomfort. Cervical samples collected with the new SCT kit compared well to traditional liquid-based samples tested by AHPV. Although there was good agreement between self-collected and physician-collected samples with the SCT, in a limited number of 30 women, vaginal sampling identified fewer with CIN2+ precancerous cervical lesions than cervical SCT sampling. Comfort, ease of use, and detection of high-risk HPV demonstrated that the kit could be used for cervical and vaginal sampling.

  13. NHEXAS PHASE I ARIZONA STUDY--STANDARD OPERATING PROCEDURE FOR FIELD COLLECTION OF YARD COMPOSITE SOIL SAMPLES (UA-F-5.1)

    EPA Science Inventory

    The purpose of this SOP is to establish a uniform procedure for the collection of yard composite soil samples in the field. This procedure was followed to ensure consistent and reliable collection of outdoor soil samples during the Arizona NHEXAS project and the "Border" study. ...

  14. NHEXAS PHASE I ARIZONA STUDY--STANDARD OPERATING PROCEDURE FOR FIELD COLLECTION OF RESIDENTIAL FOUNDATION SOIL SAMPLES (UA-F-6.1)

    EPA Science Inventory

    The purpose of this SOP is to establish a uniform procedure for the collection of residential foundation soil samples in the field. This procedure was followed to ensure consistent and reliable collection of outdoor soil samples during the Arizona NHEXAS project and the "Border"...

  15. Preparation and validation of gross alpha/beta samples used in EML`s quality assessment program

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Scarpitta, S.C.

    1997-10-01

    A set of water and filter samples have been incorporated into the existing Environmental Measurements Laboratory`s (EML) Quality Assessment Program (QAP) for gross alpha/beta determinations by participating DOE laboratories. The participating laboratories are evaluated by comparing their results with the EML value. The preferred EML method for measuring water and filter samples, described in this report, uses gas flow proportional counters with 2 in. detectors. Procedures for sample preparation, quality control and instrument calibration are presented. Liquid scintillation (LS) counting is an alternative technique that is suitable for quantifying both the alpha ({sup 241}Am, {sup 230}Th and {sup 238}Pu) andmore » beta ({sup 90}Sr/{sup 90}Y) activity concentrations in the solutions used to prepare the QAP water and air filter samples. Three LS counting techniques (Cerenkov, dual dpm and full spectrum analysis) are compared. These techniques may be used to validate the activity concentrations of each component in the alpha/beta solution before the QAP samples are actually prepared.« less

  16. Airborne detection and quantification of swine influenza a virus in air samples collected inside, outside and downwind from swine barns.

    PubMed

    Corzo, Cesar A; Culhane, Marie; Dee, Scott; Morrison, Robert B; Torremorell, Montserrat

    2013-01-01

    Airborne transmission of influenza A virus (IAV) in swine is speculated to be an important route of virus dissemination, but data are scarce. This study attempted to detect and quantify airborne IAV by virus isolation and RRT-PCR in air samples collected under field conditions. This was accomplished by collecting air samples from four acutely infected pig farms and locating air samplers inside the barns, at the external exhaust fans and downwind from the farms at distances up to 2.1 km. IAV was detected in air samples collected in 3 out of 4 farms included in the study. Isolation of IAV was possible from air samples collected inside the barn at two of the farms and in one farm from the exhausted air. Between 13% and 100% of samples collected inside the barns tested RRT-PCR positive with an average viral load of 3.20E+05 IAV RNA copies/m³ of air. Percentage of exhaust positive air samples also ranged between 13% and 100% with an average viral load of 1.79E+04 RNA copies/m³ of air. Influenza virus RNA was detected in air samples collected between 1.5 and 2.1 Km away from the farms with viral levels significantly lower at 4.65E+03 RNA copies/m³. H1N1, H1N2 and H3N2 subtypes were detected in the air samples and the hemagglutinin gene sequences identified in the swine samples matched those in aerosols providing evidence that the viruses detected in the aerosols originated from the pigs in the farms under study. Overall our results indicate that pigs can be a source of IAV infectious aerosols and that these aerosols can be exhausted from pig barns and be transported downwind. The results from this study provide evidence of the risk of aerosol transmission in pigs under field conditions.

  17. Airborne Detection and Quantification of Swine Influenza A Virus in Air Samples Collected Inside, Outside and Downwind from Swine Barns

    PubMed Central

    Corzo, Cesar A.; Culhane, Marie; Dee, Scott; Morrison, Robert B.; Torremorell, Montserrat

    2013-01-01

    Airborne transmission of influenza A virus (IAV) in swine is speculated to be an important route of virus dissemination, but data are scarce. This study attempted to detect and quantify airborne IAV by virus isolation and RRT-PCR in air samples collected under field conditions. This was accomplished by collecting air samples from four acutely infected pig farms and locating air samplers inside the barns, at the external exhaust fans and downwind from the farms at distances up to 2.1 km. IAV was detected in air samples collected in 3 out of 4 farms included in the study. Isolation of IAV was possible from air samples collected inside the barn at two of the farms and in one farm from the exhausted air. Between 13% and 100% of samples collected inside the barns tested RRT-PCR positive with an average viral load of 3.20E+05 IAV RNA copies/m3 of air. Percentage of exhaust positive air samples also ranged between 13% and 100% with an average viral load of 1.79E+04 RNA copies/m3 of air. Influenza virus RNA was detected in air samples collected between 1.5 and 2.1 Km away from the farms with viral levels significantly lower at 4.65E+03 RNA copies/m3. H1N1, H1N2 and H3N2 subtypes were detected in the air samples and the hemagglutinin gene sequences identified in the swine samples matched those in aerosols providing evidence that the viruses detected in the aerosols originated from the pigs in the farms under study. Overall our results indicate that pigs can be a source of IAV infectious aerosols and that these aerosols can be exhausted from pig barns and be transported downwind. The results from this study provide evidence of the risk of aerosol transmission in pigs under field conditions. PMID:23951164

  18. Human Exploration of Near-Earth Asteroids and Sample Collection Considerations

    NASA Technical Reports Server (NTRS)

    Abell, Paul

    2013-01-01

    In 2009 the Augustine Commission identified near-Earth asteroids (NEAs) as high profile destinations for human exploration missions beyond the Earth-Moon system as part of the Flexible Path. Subsequently, the U.S. presidential administration directed NASA on April 15, 2010 to include NEAs as destinations for future human exploration with the goal of sending astronauts to a NEA in the mid to late 2020s. This directive became part of the official National Space Policy of the United States of America as of June 28, 2010. Human Exploration Considerations: These missions would be the first human expeditions to interplanetary bodies beyond the Earth-Moon system and would prove useful for testing technologies required for human missions to Mars, Phobos and Deimos, and other Solar System destinations. Missions to NEAs would undoubtedly provide a great deal of technical and engineering data on spacecraft operations for future human space exploration while conducting in-depth scientific examinations of these primitive objects. However, prior to sending human explorers to NEAs, robotic investigations of these bodies would be required in order to maximize operational efficiency and reduce mission risk. These precursor missions to NEAs would fill crucial strategic knowledge gaps concerning their physical characteristics that are relevant for human exploration of these relatively unknown destinations. Sample Science Benefits: Information obtained from a human investigation of a NEA, together with ground-based observations and prior spacecraft investigations of asteroids and comets, will also provide a real measure of ground truth to data obtained from terrestrial meteorite collections. Major advances in the areas of geochemistry, impact history, thermal history, isotope analyses, mineralogy, space weathering, formation ages, thermal inertias, volatile content, source regions, solar system formation, etc. can be expected from human NEA missions. Samples directly returned from a

  19. 76 FR 24053 - Agency Information Collection Activities: Proposed Collection; Comments Requested

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-04-29

    ... that captures valid, reliable data on the nature and extent of intimate partner violence, sexual... Information Collection Activity; Comment Request, Proposed Project entitled ``Violence and Victimization... Collection: (1) Type of Information Collection: Survey. (2) The title of the Form/Collection: Violence and...

  20. Assessing decentering: validation, psychometric properties, and clinical usefulness of the Experiences Questionnaire in a Spanish sample.

    PubMed

    Soler, Joaquim; Franquesa, Alba; Feliu-Soler, Albert; Cebolla, Ausias; García-Campayo, Javier; Tejedor, Rosa; Demarzo, Marcelo; Baños, Rosa; Pascual, Juan Carlos; Portella, Maria J

    2014-11-01

    Decentering is defined as the ability to observe one's thoughts and feelings in a detached manner. The Experiences Questionnaire (EQ) is a self-report instrument that originally assessed decentering and rumination. The purpose of this study was to evaluate the psychometric properties of the Spanish version of EQ-Decentering and to explore its clinical usefulness. The 11-item EQ-Decentering subscale was translated into Spanish and psychometric properties were examined in a sample of 921 adult individuals, 231 with psychiatric disorders and 690 without. The subsample of nonpsychiatric participants was also split according to their previous meditative experience (meditative participants, n=341; and nonmeditative participants, n=349). Additionally, differences among these three subgroups were explored to determine clinical validity of the scale. Finally, EQ-Decentering was administered twice in a group of borderline personality disorder, before and after a 10-week mindfulness intervention. Confirmatory factor analysis indicated acceptable model fit, sbχ(2)=243.8836 (p<.001), CFI=.939, GFI=.936, SRMR=.040, and RMSEA=.06 (.060-.077), and psychometric properties were found to be satisfactory (reliability: Cronbach's α=.893; convergent validity: r>.46; and divergent validity: r<-.35). The scale detected changes in decentering after a 10-session intervention in mindfulness (t=-4.692, p<.00001). Differences among groups were significant (F=134.8, p<.000001), where psychiatric participants showed the lowest scores compared to nonpsychiatric meditative and nonmeditative participants. The Spanish version of the EQ-Decentering is a valid and reliable instrument to assess decentering either in clinical and nonclinical samples. In addition, the findings show that EQ-Decentering seems an adequate outcome instrument to detect changes after mindfulness-based interventions. Copyright © 2014. Published by Elsevier Ltd.

  1. Validation of a Spanish-language version of the ADHD Rating Scale IV in a Spanish sample.

    PubMed

    Vallejo-Valdivielso, M; Soutullo, C A; de Castro-Manglano, P; Marín-Méndez, J J; Díez-Suárez, A

    2017-07-14

    The purpose of this study is to validate a Spanish-language version of the 18-item ADHD Rating Scale-IV (ADHD-RS-IV.es) in a Spanish sample. From a total sample of 652 children and adolescents aged 6 to 17 years (mean age was 11.14±3.27), we included 518 who met the DSM-IV-TR criteria for ADHD and 134 healthy controls. To evaluate the factorial structure, validity, and reliability of the scale, we performed a confirmatory factor analysis (CFA) using structural equation modelling on a polychoric correlation matrix and maximum likelihood estimation. The scale's discriminant validity and predictive value were estimated using ROC (receiver operating characteristics) curve analysis. Both the full scale and the subscales of the Spanish-language version of the ADHD-RS-IV showed good internal consistency. Cronbach's alpha was 0.94 for the full scale and ≥ 0.90 for the subscales, and ordinal alpha was 0.95 and ≥ 0.90, respectively. CFA showed that a two-factor model (inattention and hyperactivity/impulsivity) provided the best fit for the data. ADHD-RS-IV.es offered good discriminant ability to distinguish between patients with ADHD and controls (AUC=0.97). The two-factor structure of the Spanish-language version of the ADHD-RS-IV (ADHD-RS-IV.es) is consistent with those of the DSM-IV-TR and DSM-5 as well as with the model proposed by the author of the original scale. Furthermore, it has good discriminant ability. ADHD-RS-IV.es is therefore a valid and reliable tool for determining presence and severity of ADHD symptoms in the Spanish population. Copyright © 2017 Sociedad Española de Neurología. Publicado por Elsevier España, S.L.U. All rights reserved.

  2. Assessing the reliability and validity of the Chinese Sexual Assault Symptom Scale (C-SASS): scale development and validation.

    PubMed

    Wang, Chang-Hwai; Lee, Jin-Chuan; Yuan, Yu-Hsi

    2014-01-01

    The purpose of this research is to establish and verify the psychometric and structural properties of the self-report Chinese Sexual Assault Symptom Scale (C-SASS) to assess the trauma experienced by Chinese victims of sexual assault. An earlier version of the C-SASS was constructed using a modified list of the same trauma symptoms administered to an American sample and used to develop and validate the Sexual Assault Symptom Scale II (SASS II). The rationale of this study is to revise the earlier version of the C-SASS, using a larger and more representative sample and more robust statistical analysis than in earlier research, to permit a more thorough examination of the instrument and further confirm the dimensions of sexual assault trauma in Chinese victims of rape. In this study, a sample of 418 victims from northern Taiwan was collected to confirm the reliability and validity of the C-SASS. Exploratory factor analysis yielded five common factors: Safety Fears, Self-Blame, Health Fears, Anger and Emotional Lability, and Fears About the Criminal Justice System. Further tests of the validity and composite reliability of the C-SASS were provided by the structural equation modeling (SEM). The results indicated that the C-SASS was a brief, valid, and reliable instrument for assessing sexual assault trauma among Chinese victims in Taiwan. The scale can be used to evaluate victims in sexual assault treatment centers around Taiwan, as well as to capture the characteristics of sexual assault trauma among Chinese victims.

  3. How Differences among Data Collectors Are Reflected in the Reliability and Validity of Data Collected by Likert-Type Scales?

    ERIC Educational Resources Information Center

    Köksal, Mustafa Serdar; Ertekin, Pelin; Çolakoglu, Özgür Murat

    2014-01-01

    The purpose of this study is to investigate association of data collectors' differences with the differences in reliability and validity of scores regarding affective variables (motivation toward science learning and science attitude) that are measured by Likert-type scales. Four researchers trained in data collection and seven science teachers…

  4. A pilot study to understand feasibility and acceptability of stool and cord blood sample collection for a large-scale longitudinal birth cohort.

    PubMed

    Bailey, S R; Townsend, C L; Dent, H; Mallet, C; Tsaliki, E; Riley, E M; Noursadeghi, M; Lawley, T D; Rodger, A J; Brocklehurst, P; Field, N

    2017-12-28

    Few data are available to guide biological sample collection around the time of birth for large-scale birth cohorts. We are designing a large UK birth cohort to investigate the role of infection and the developing immune system in determining future health and disease. We undertook a pilot to develop methodology for the main study, gain practical experience of collecting samples, and understand the acceptability of sample collection to women in late pregnancy. Between February-July 2014, we piloted the feasibility and acceptability of collecting maternal stool, baby stool and cord blood samples from participants recruited at prolonged pregnancy and planned pre-labour caesarean section clinics at University College London Hospital. Participating women were asked to complete acceptability questionnaires. Overall, 265 women were approached and 171 (65%) participated, with ≥1 sample collected from 113 women or their baby (66%). Women had a mean age of 34 years, were primarily of white ethnicity (130/166, 78%), and half were nulliparous (86/169, 51%). Women undergoing planned pre-labour caesarean section were more likely than those who delivered vaginally to provide ≥1 sample (98% vs 54%), but less likely to provide maternal stool (10% vs 43%). Pre-sample questionnaires were completed by 110/171 women (64%). Most women reported feeling comfortable with samples being collected from their baby (<10% uncomfortable), but were less comfortable about their own stool (19% uncomfortable) or a vaginal swab (24% uncomfortable). It is possible to collect a range of biological samples from women around the time of delivery, and this was acceptable for most women. These data inform study design and protocol development for large-scale birth cohorts.

  5. The Cross-Cultural Validity of the MMPI-2-RF Higher-Order Scales in a Sample of North Korean Female Refugees.

    PubMed

    Kim, Seong-Hyeon; Goodman, Grace M; Toruno, Joseph A; Sherry, Alissa R; Kim, Hee Kyung

    2015-10-01

    We investigated the cross-cultural factorial validity of the three Higher-Order (H-O) scales in the Minnesota Multiphasic Personality Inventory-2 Restructured Form (MMPI-2-RF) among a sample of North Korean female refugees (N = 2,732). Given the importance of the H-O scales in the overall structure of the MMPI-2-RF scales and in interpretation, we were interested in exploring their cross-cultural validity. We conducted an exploratory factor analysis (EFA) on the nine Restructured Clinical (RC) scale raw scores and fitted and compared one- to three-factor models. The three-factor model, akin to the model in Tellegen and Ben-Porath, demonstrated the best fit to the data. Furthermore, the pattern matrices of loadings across the current sample and the U.S. samples were comparable despite some differences, such as the RC2 scale's salient, negative loading on a factor analogous to the Behavioral/Externalizing Dysfunction scale. We also investigated the unique psychological characteristics of the refugees, possibly resulting from the arduous, perilous journeys out of North Korea taken by this group of female refugees and discussed the results of EFA in light of those singular psychological traits and experiences. Overall, the three H-O scales of the Korean MMPI-2-RF evidenced reasonable cross-cultural factorial validity among the sample of North Korean female refugees. © The Author(s) 2014.

  6. Astronaut Charles Duke photographed collecting lunar samples at Station 1

    NASA Image and Video Library

    1972-04-21

    AS16-114-18423 (21 April 1972) --- Astronaut Charles M. Duke Jr., lunar module pilot, is photographed collecting lunar samples at Station No. 1, during the first Apollo 16 extravehicular activity (EVA), at the Descartes landing site. This picture, looking eastward, was taken by astronaut John W. Young, commander. Duke is standing at the rim of Plum Crater. The parked Lunar Roving Vehicle (LRV) can be seen in the left background. While astronauts Young and Duke descended in the Lunar Module (LM) "Orion" to explore the Descartes highlands region of the moon, astronaut Thomas K. Mattingly II, command module pilot, remained with the Command and Service Modules (CSM) "Casper" in lunar orbit.

  7. Floating sample-collection platform with stage-activated automatic water sampler for streams with large variation in stage

    USGS Publications Warehouse

    Tarte, Stephen R.; Schmidt, A.R.; Sullivan, Daniel J.

    1992-01-01

    A floating sample-collection platform is described for stream sites where the vertical or horizontal distance between the stream-sampling point and a safe location for the sampler exceed the suction head of the sampler. The platform allows continuous water sampling over the entire storm-runoff hydrogrpah. The platform was developed for a site in southern Illinois.

  8. Aerosol sampling system for collection of Capstone depleted uranium particles in a high-energy environment.

    PubMed

    Holmes, Thomas D; Guilmette, Raymond A; Cheng, Yung Sung; Parkhurst, Mary Ann; Hoover, Mark D

    2009-03-01

    The Capstone Depleted Uranium (DU) Aerosol Study was undertaken to obtain aerosol samples resulting from a large-caliber DU penetrator striking an Abrams or Bradley test vehicle. The sampling strategy was designed to (1) optimize the performance of the samplers and maintain their integrity in the extreme environment created during perforation of an armored vehicle by a DU penetrator, (2) collect aerosols as a function of time post perforation, and (3) obtain size-classified samples for analysis of chemical composition, particle morphology, and solubility in lung fluid. This paper describes the experimental setup and sampling methodologies used to achieve these objectives. Custom-designed arrays of sampling heads were secured to the inside of the target in locations approximating the breathing zones of the crew locations in the test vehicles. Each array was designed to support nine filter cassettes and nine cascade impactors mounted with quick-disconnect fittings. Shielding and sampler placement strategies were used to minimize sampler loss caused by the penetrator impact and the resulting fragments of eroded penetrator and perforated armor. A cyclone train was used to collect larger quantities of DU aerosol for measurement of chemical composition and solubility. A moving filter sample was used to obtain semicontinuous samples for DU concentration determination. Control for the air samplers was provided by five remotely located valve control and pressure monitoring units located inside and around the test vehicle. These units were connected to a computer interface chassis and controlled using a customized LabVIEW engineering computer control program. The aerosol sampling arrays and control systems for the Capstone study provided the needed aerosol samples for physicochemical analysis, and the resultant data were used for risk assessment of exposure to DU aerosol.

  9. Aerosol Sampling System for Collection of Capstone Depleted Uranium Particles in a High-Energy Environment

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Holmes, Thomas D.; Guilmette, Raymond A.; Cheng, Yung-Sung

    2009-03-01

    The Capstone Depleted Uranium Aerosol Study was undertaken to obtain aerosol samples resulting from a kinetic-energy cartridge with a large-caliber depleted uranium (DU) penetrator striking an Abrams or Bradley test vehicle. The sampling strategy was designed to (1) optimize the performance of the samplers and maintain their integrity in the extreme environment created during perforation of an armored vehicle by a DU penetrator, (2) collect aerosols as a function of time post-impact, and (3) obtain size-classified samples for analysis of chemical composition, particle morphology, and solubility in lung fluid. This paper describes the experimental setup and sampling methodologies used tomore » achieve these objectives. Custom-designed arrays of sampling heads were secured to the inside of the target in locations approximating the breathing zones of the vehicle commander, loader, gunner, and driver. Each array was designed to support nine filter cassettes and nine cascade impactors mounted with quick-disconnect fittings. Shielding and sampler placement strategies were used to minimize sampler loss caused by the penetrator impact and the resulting fragments of eroded penetrator and perforated armor. A cyclone train was used to collect larger quantities of DU aerosol for chemical composition and solubility. A moving filter sample was used to obtain semicontinuous samples for depleted uranium concentration determination. Control for the air samplers was provided by five remotely located valve control and pressure monitoring units located inside and around the test vehicle. These units were connected to a computer interface chassis and controlled using a customized LabVIEW engineering computer control program. The aerosol sampling arrays and control systems for the Capstone study provided the needed aerosol samples for physicochemical analysis, and the resultant data were used for risk assessment of exposure to DU aerosol.« less

  10. Collective Socialization and Child Conduct Problems: A Multilevel Analysis with an African American Sample

    ERIC Educational Resources Information Center

    Simons, Leslie Gordon; Simons, Ronald L.; Conger, Rand D.; Brody, Gene H.

    2004-01-01

    This article uses hierarchical linear modeling with a sample of African American children and their primary caregivers to examine the association between various community factors and child conduct problems. The analysis revealed a rather strong inverse association between level of collective socialization and conduct problems. This relationship…

  11. Validation of the Cognition Test Battery for Spaceflight in a Sample of Highly Educated Adults.

    PubMed

    Moore, Tyler M; Basner, Mathias; Nasrini, Jad; Hermosillo, Emanuel; Kabadi, Sushila; Roalf, David R; McGuire, Sarah; Ecker, Adrian J; Ruparel, Kosha; Port, Allison M; Jackson, Chad T; Dinges, David F; Gur, Ruben C

    2017-10-01

    Neuropsychological changes that may occur due to the environmental and psychological stressors of prolonged spaceflight motivated the development of the Cognition Test Battery. The battery was designed to assess multiple domains of neurocognitive functions linked to specific brain systems. Tests included in Cognition have been validated, but not in high-performing samples comparable to astronauts, which is an essential step toward ensuring their usefulness in long-duration space missions. We administered Cognition (on laptop and iPad) and the WinSCAT, counterbalanced for order and version, in a sample of 96 subjects (50% women; ages 25-56 yr) with at least a Master's degree in science, technology, engineering, or mathematics (STEM). We assessed the associations of age, sex, and administration device with neurocognitive performance, and compared the scores on the Cognition battery with those of WinSCAT. Confirmatory factor analysis compared the structure of the iPad and laptop administration methods using Wald tests. Age was associated with longer response times (mean β = 0.12) and less accurate (mean β = -0.12) performance, women had longer response times on psychomotor (β = 0.62), emotion recognition (β = 0.30), and visuo-spatial (β = 0.48) tasks, men outperformed women on matrix reasoning (β = -0.34), and performance on an iPad was generally faster (mean β = -0.55). The WinSCAT appeared heavily loaded with tasks requiring executive control, whereas Cognition assessed a larger variety of neurocognitive domains. Overall results supported the interpretation of Cognition scores as measuring their intended constructs in high performing astronaut analog samples.Moore TM, Basner M, Nasrini J, Hermosillo E, Kabadi S, Roalf DR, McGuire S, Ecker AJ, Ruparel K, Port AM, Jackson CT, Dinges DF, Gur RC. Validation of the Cognition Test Battery for spaceflight in a sample of highly educated adults. Aerosp Med Hum Perform. 2017; 88(10):937-946.

  12. Molecular dynamics based enhanced sampling of collective variables with very large time steps.

    PubMed

    Chen, Pei-Yang; Tuckerman, Mark E

    2018-01-14

    Enhanced sampling techniques that target a set of collective variables and that use molecular dynamics as the driving engine have seen widespread application in the computational molecular sciences as a means to explore the free-energy landscapes of complex systems. The use of molecular dynamics as the fundamental driver of the sampling requires the introduction of a time step whose magnitude is limited by the fastest motions in a system. While standard multiple time-stepping methods allow larger time steps to be employed for the slower and computationally more expensive forces, the maximum achievable increase in time step is limited by resonance phenomena, which inextricably couple fast and slow motions. Recently, we introduced deterministic and stochastic resonance-free multiple time step algorithms for molecular dynamics that solve this resonance problem and allow ten- to twenty-fold gains in the large time step compared to standard multiple time step algorithms [P. Minary et al., Phys. Rev. Lett. 93, 150201 (2004); B. Leimkuhler et al., Mol. Phys. 111, 3579-3594 (2013)]. These methods are based on the imposition of isokinetic constraints that couple the physical system to Nosé-Hoover chains or Nosé-Hoover Langevin schemes. In this paper, we show how to adapt these methods for collective variable-based enhanced sampling techniques, specifically adiabatic free-energy dynamics/temperature-accelerated molecular dynamics, unified free-energy dynamics, and by extension, metadynamics, thus allowing simulations employing these methods to employ similarly very large time steps. The combination of resonance-free multiple time step integrators with free-energy-based enhanced sampling significantly improves the efficiency of conformational exploration.

  13. Molecular dynamics based enhanced sampling of collective variables with very large time steps

    NASA Astrophysics Data System (ADS)

    Chen, Pei-Yang; Tuckerman, Mark E.

    2018-01-01

    Enhanced sampling techniques that target a set of collective variables and that use molecular dynamics as the driving engine have seen widespread application in the computational molecular sciences as a means to explore the free-energy landscapes of complex systems. The use of molecular dynamics as the fundamental driver of the sampling requires the introduction of a time step whose magnitude is limited by the fastest motions in a system. While standard multiple time-stepping methods allow larger time steps to be employed for the slower and computationally more expensive forces, the maximum achievable increase in time step is limited by resonance phenomena, which inextricably couple fast and slow motions. Recently, we introduced deterministic and stochastic resonance-free multiple time step algorithms for molecular dynamics that solve this resonance problem and allow ten- to twenty-fold gains in the large time step compared to standard multiple time step algorithms [P. Minary et al., Phys. Rev. Lett. 93, 150201 (2004); B. Leimkuhler et al., Mol. Phys. 111, 3579-3594 (2013)]. These methods are based on the imposition of isokinetic constraints that couple the physical system to Nosé-Hoover chains or Nosé-Hoover Langevin schemes. In this paper, we show how to adapt these methods for collective variable-based enhanced sampling techniques, specifically adiabatic free-energy dynamics/temperature-accelerated molecular dynamics, unified free-energy dynamics, and by extension, metadynamics, thus allowing simulations employing these methods to employ similarly very large time steps. The combination of resonance-free multiple time step integrators with free-energy-based enhanced sampling significantly improves the efficiency of conformational exploration.

  14. Cross Validation of Two Partitioning-Based Sampling Approaches in Mesocosms Containing PCB Contaminated Field Sediment, Biota, and Activated Carbon Amendment.

    PubMed

    Schmidt, Stine N; Wang, Alice P; Gidley, Philip T; Wooley, Allyson H; Lotufo, Guilherme R; Burgess, Robert M; Ghosh, Upal; Fernandez, Loretta A; Mayer, Philipp

    2017-09-05

    The Gold Standard for determining freely dissolved concentrations (C free ) of hydrophobic organic compounds in sediment interstitial water would be in situ deployment combined with equilibrium sampling, which is generally difficult to achieve. In the present study, ex situ equilibrium sampling with multiple thicknesses of silicone and in situ pre-equilibrium sampling with low density polyethylene (LDPE) loaded with performance reference compounds were applied independently to measure polychlorinated biphenyls (PCBs) in mesocosms with (1) New Bedford Harbor sediment (MA, U.S.A.), (2) sediment and biota, and (3) activated carbon amended sediment and biota. The aim was to cross validate the two different sampling approaches. Around 100 PCB congeners were quantified in the two sampling polymers, and the results confirmed the good precision of both methods and were in overall good agreement with recently published LDPE to silicone partition ratios. Further, the methods yielded C free in good agreement for all three experiments. The average ratio between C free determined by the two methods was factor 1.4 ± 0.3 (range: 0.6-2.0), and the results thus cross-validated the two sampling approaches. For future investigations, specific aims and requirements in terms of application, data treatment, and data quality requirements should dictate the selection of the most appropriate partitioning-based sampling approach.

  15. The Construct Validity of the Dutch Personality Inventory for DSM-5 Personality Disorders (PID-5) in a Clinical Sample.

    PubMed

    Bastiaens, Tim; Claes, Laurence; Smits, Dirk; De Clercq, Barbara; De Fruyt, Filip; Rossi, Gina; Vanwalleghem, Dominique; Vermote, Rudi; Lowyck, Benedicte; Claes, Stephan; De Hert, Marc

    2016-02-01

    The factor structure and the convergent validity of the Personality Inventory for DSM-5 (PID-5), a self-report questionnaire designed to measure personality pathology as advocated in the fifth edition, Section III of Diagnostic and Statistical Manual of Mental Disorders (DSM-5), are already demonstrated in general population samples, but need replication in clinical samples. In 240 Flemish inpatients, we examined the factor structure of the PID-5 by means of exploratory structural equation modeling. Additionally, we investigated differences in PID-5 higher order domain scores according to gender, age and educational level, and explored convergent and discriminant validity by relating the PID-5 with the Dimensional Assessment of Personality Pathology-Basic Questionnaire and by comparing PID-5 scores of inpatients with and without a DSM-IV categorical personality disorder diagnosis. Our results confirmed the original five-factor structure of the PID-5. The reliability and the convergent and discriminant validity of the PID-5 proved to be adequate. Implications for future research are discussed. © The Author(s) 2015.

  16. Development and Validation of a Quantitative Food Frequency Questionnaire among Rural- and Urban-Dwelling Adults in Colombia

    ERIC Educational Resources Information Center

    Dehghan, Mahshid; Lopez Jaramillo, Patricio; Duenas, Ruby; Anaya, Lilliam Lima; Garcia, Ronald G.; Zhang, Xiaohe; Islam, Shofiqul; Merchant, Anwar T.

    2012-01-01

    Objective: To validate a food frequency questionnaire (FFQ) against multiple 24-hour dietary recalls (DRs) that could be used for Colombian adults. Methods: A convenience sample of 219 individuals participated in the study. The validity of the FFQ was evaluated against multiple DRs. Four dietary recalls were collected during the year, and an FFQ…

  17. Assessing collective affect recognition via the Emotional Aperture Measure.

    PubMed

    Sanchez-Burks, Jeffrey; Bartel, Caroline A; Rees, Laura; Huy, Quy

    2016-01-01

    Curiosity about collective affect is undergoing a revival in many fields. This literature, tracing back to Le Bon's seminal work on crowd psychology, has established the veracity of collective affect and demonstrated its influence on a wide range of group dynamics. More recently, an interest in the perception of collective affect has emerged, revealing a need for a methodological approach for assessing collective emotion recognition to complement measures of individual emotion recognition. This article addresses this need by introducing the Emotional Aperture Measure (EAM). Three studies provide evidence that collective affect recognition requires a processing style distinct from individual emotion recognition and establishes the validity and reliability of the EAM. A sample of working managers further shows how the EAM provides unique insights into how individuals interact with collectives. We discuss how the EAM can advance several lines of research on collective affect.

  18. A novel personal air sampling device for collecting volatile organic compounds: a comparison to charcoal tubes and diffusive badges.

    PubMed

    Rossner, Alan; Farant, Jean-Pierre

    2004-02-01

    Evacuated canisters have been used for many years to collect ambient air samples for gases and vapors. Recently, significant interest has arisen in using evacuated canisters for personal breathing zone sampling as an alternative to sorbent sampling. A novel flow control device was designed and built at McGill University. The flow control device was designed to provide a very low flow rate, <0.5 mL/min, to allow a sample to be collected over an extended period of time. Previous experiments run at McGill have shown agreement between the mathematical and empirical models to predict flow rate. The flow control device combined with an evacuated canister (capillary flow control-canister) was used in a series of experiments to evaluate its performance against charcoal tubes and diffusive badges. Air samples of six volatile organic compounds were simultaneously collected in a chamber using the capillary flow control-canister, charcoal tubes, and diffusive badges. Five different concentrations of the six volatile organic compounds were evaluated. The results from the three sampling devices were compared to each other and to concentration values obtained using an online gas chromatograph (GC). Eighty-four samples of each method were collected for each of the six chemicals. Results indicate that the capillary flow control-canister device compares quite favorably to the online GC and to the charcoal tubes, p > 0.05 for most of the tests. The capillary flow control-canister was found to be more accurate for the compounds evaluated, easier to use, and easier to analyze than charcoal tubes and passive dosimeter badges.

  19. Critical review and meta-analysis of spurious hemolysis in blood samples collected from intravenous catheters

    PubMed Central

    Lippi, Giuseppe; Cervellin, Gianfranco; Mattiuzzi, Camilla

    2013-01-01

    Background: A number of preanalytical activities strongly influence sample quality, especially those related to sample collection. Since blood drawing through intravenous catheters is reported as a potential source of erythrocyte injury, we performed a critical review and meta-analysis about the risk of catheter-related hemolysis. Materials and methods: We performed a systematic search on PubMed, Web of Science and Scopus to estimate the risk of spurious hemolysis in blood samples collected from intravenous catheters. A meta-analysis with calculation of Odds ratio (OR) and Relative risk (RR) along with 95% Confidence interval (95% CI) was carried out using random effect mode. Results: Fifteen articles including 17 studies were finally selected. The total number of patients was 14,796 in 13 studies assessing catheter and evacuated tubes versus straight needle and evacuated tubes, and 1251 in 4 studies assessing catheter and evacuated tubes versus catheter and manual aspiration. A significant risk of hemolysis was found in studies assessing catheter and evacuated tubes versus straight needle and evacuated tubes (random effect OR 3.4; 95% CI = 2.9–3.9 and random effect RR 1.07; 95% CI = 1.06–1.08), as well as in studies assessing catheter and evacuated tubes versus catheter and manual aspiration of blood (OR 3.7; 95% CI = 2.7–5.1 and RR 1.32; 95% CI = 1.24–1.40). Conclusions: Sample collection through intravenous catheters is associated with significant higher risk of spurious hemolysis as compared with standard blood drawn by straight needle, and this risk is further amplified when intravenous catheter are associated with primary evacuated blood tubes as compared with manual aspiration. PMID:23894864

  20. Predicting dementia risk in primary care: development and validation of the Dementia Risk Score using routinely collected data.

    PubMed

    Walters, K; Hardoon, S; Petersen, I; Iliffe, S; Omar, R Z; Nazareth, I; Rait, G

    2016-01-21

    Existing dementia risk scores require collection of additional data from patients, limiting their use in practice. Routinely collected healthcare data have the potential to assess dementia risk without the need to collect further information. Our objective was to develop and validate a 5-year dementia risk score derived from primary healthcare data. We used data from general practices in The Health Improvement Network (THIN) database from across the UK, randomly selecting 377 practices for a development cohort and identifying 930,395 patients aged 60-95 years without a recording of dementia, cognitive impairment or memory symptoms at baseline. We developed risk algorithm models for two age groups (60-79 and 80-95 years). An external validation was conducted by validating the model on a separate cohort of 264,224 patients from 95 randomly chosen THIN practices that did not contribute to the development cohort. Our main outcome was 5-year risk of first recorded dementia diagnosis. Potential predictors included sociodemographic, cardiovascular, lifestyle and mental health variables. Dementia incidence was 1.88 (95% CI, 1.83-1.93) and 16.53 (95% CI, 16.15-16.92) per 1000 PYAR for those aged 60-79 (n = 6017) and 80-95 years (n = 7104), respectively. Predictors for those aged 60-79 included age, sex, social deprivation, smoking, BMI, heavy alcohol use, anti-hypertensive drugs, diabetes, stroke/TIA, atrial fibrillation, aspirin, depression. The discrimination and calibration of the risk algorithm were good for the 60-79 years model; D statistic 2.03 (95% CI, 1.95-2.11), C index 0.84 (95% CI, 0.81-0.87), and calibration slope 0.98 (95% CI, 0.93-1.02). The algorithm had a high negative predictive value, but lower positive predictive value at most risk thresholds. Discrimination and calibration were poor for the 80-95 years model. Routinely collected data predicts 5-year risk of recorded diagnosis of dementia for those aged 60-79, but not those aged 80+. This

  1. Validation of the Portuguese version of the Brief Multidimensional Measure of Religiousness/Spirituality (BMMRS-P) in clinical and non-clinical samples.

    PubMed

    Curcio, Cristiane Schumann Silva; Lucchetti, Giancarlo; Moreira-Almeida, Alexander

    2015-04-01

    Despite Brazil's high levels of religious involvement, there is a scarcity of validated religiousness/spirituality (R/S) measures in Portuguese, particularly multidimensional ones. This study presents the validation of the Portuguese version of the "Brief Multidimensional Measure in Religiousness and Spirituality" (BMMRS) within the Brazilian context. Inpatients (262) and caregivers (389) at two hospitals of Brazil answered the BMMRS, the DUREL-p, and a sociodemographic questionnaire. The internal and convergent validity and test-retest reliability for major dimensions were good. Discriminant validity was high (except for the Forgiveness dimension). The Portuguese version of the BMMRS is a reliable and valid instrument to assess multiple R/S dimensions in clinical and non-clinical samples.

  2. Validation of an enzyme-linked immunosorbent assay screening method and a liquid chromatography-tandem mass spectrometry confirmation method for the identification and quantification of ketamine and norketamine in urine samples from Malaysia.

    PubMed

    Harun, Norlida; Anderson, Robert A; Miller, Eleanor I

    2009-01-01

    An ELISA and a liquid chromatography-tandem mass spectrometry (LC-MS-MS) confirmation method were developed and validated for the identification and quantitation of ketamine and its major metabolite norketamine in urine samples. The Neogen ketamine microplate ELISA was optimized with respect to sample and enzyme conjugate volumes and the sample preincubation time before addition of the enzyme conjugate. The ELISA kit was validated to include an assessment of the dose-response curve, intra- and interday precision, limit of detection (LOD), and cross-reactivity. The sensitivity and specificity were calculated by comparison to the results from the validated LC-MS-MS confirmation method. An LC-MS-MS method was developed and validated with respect to LOD, lower limit of quantitation (LLOQ), linearity, recovery, intra- and interday precision, and matrix effects. The ELISA dose-response curve was a typical S-shaped binding curve, with a linear portion of the graph observed between 25 and 500 ng/mL for ketamine. The cross-reactivity of 200 ng/mL norketamine to ketamine was 2.1%, and no cross-reactivity was detected with 13 common drugs tested at 10,000 ng/mL. The ELISA LOD was calculated to be 5 ng/mL. Both intra- (n = 10) and interday (n = 50) precisions were below 5.0% at 25 ng/mL. The LOD for ketamine and norketamine was calculated statistically to be 0.6 ng/mL. The LLOQ values were also calculated statistically and were 1.9 ng/mL and 2.1 ng/mL for ketamine and norketamine, respectively. The test linearity was 0-1200 ng/mL with correlation coefficient (R(2)) > 0.99 for both analytes. Recoveries at 50, 500, and 1000 ng/mL range from 97.9% to 113.3%. Intra- (n = 5) and interday (n = 25) precisions between extracts for ketamine and norketamine were excellent (< 10%). Matrix effects analysis showed an average ion suppression of 5.7% for ketamine and an average ion enhancement of 13.0% for norketamine for urine samples collected from six individuals. A comparison of ELISA

  3. Radiological results for samples collected on paired glass- and cellulose-fiber filters at the Sandia complex, Tonopah Test Range, Nevada

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Mizell, Steve A.; Shadel, Craig A.

    Airborne particulates are collected at U.S. Department of Energy sites that exhibit radiological contamination on the soil surface to help assess the potential for wind to transport radionuclides from the contamination sites. Collecting these samples was originally accomplished by drawing air through a cellulose-fiber filter. These filters were replaced with glass-fiber filters in March 2011. Airborne particulates were collected side by side on the two filter materials between May 2013 and May 2014. Comparisons of the sample mass and the radioactivity determinations for the side-by-side samples were undertaken to determine if the change in the filter medium produced significant results.more » The differences in the results obtained using the two filter types were assessed visually by evaluating the time series and correlation plots and statistically by conducting a nonparametric matched-pair sign test. Generally, the glass-fiber filters collect larger samples of particulates and produce higher radioactivity values for the gross alpha, gross beta, and gamma spectroscopy analyses. However, the correlation between the radioanalytical results for the glass-fiber filters and the cellulose-fiber filters was not strong enough to generate a linear regression function to estimate the glass-fiber filter sample results from the cellulose-fiber filter sample results.« less

  4. Construct validity of the Nutrition and Activity Knowledge Scale in a French sample of adolescents with mild to moderate intellectual disability.

    PubMed

    Maïano, Christophe; Bégarie, Jérôme; Morin, Alexandre J S; Garbarino, Jean-Marie; Ninot, Grégory

    2010-01-01

    The purpose of this study was to test the reliability (i.e. internal consistency and test-retest reliability) and construct validity (i.e. content validity, factor validity, measurement invariance, and latent mean invariance) of the Nutrition and Activity Knowledge Scale (NAKS) in a sample of French adolescents with mild to moderate Intellectual Disability (ID). A total sample of 260 adolescents (144 boys and 116 girls), aged between 12 and 18 years old, with mild to moderate ID was involved in two studies. In the first study, analysis of items' content reveals that many words from the original version were not understood or induced confusion. These items were reworded and simplified while retaining their original meaning. In the second study, results provided support for: (i) the factor validity and reliability of a 15-item French version of the NAKS; (ii) the measurement invariance of the resulting NAKS across genders and ID levels; (iii) the partial measurement invariance of the resulting NAKS across age groups and type of school placement. In addition, the latent means of the 15-item French version of the NAKS proved to be invariant across gender, age categories, and ID levels, but to vary across type of school placement (with adolescents schooled in self-contained classes from regular schools presenting higher levels of NAK than adolescents placed in specialized establishments). The present results thus provide preliminary evidence regarding the construct validity of a 15-item French version of the NAKS in a sample of adolescents with ID.

  5. Sample Preparation and Extraction in Small Sample Volumes Suitable for Pediatric Clinical Studies: Challenges, Advances, and Experiences of a Bioanalytical HPLC-MS/MS Method Validation Using Enalapril and Enalaprilat

    PubMed Central

    Burckhardt, Bjoern B.; Laeer, Stephanie

    2015-01-01

    In USA and Europe, medicines agencies force the development of child-appropriate medications and intend to increase the availability of information on the pediatric use. This asks for bioanalytical methods which are able to deal with small sample volumes as the trial-related blood lost is very restricted in children. Broadly used HPLC-MS/MS, being able to cope with small volumes, is susceptible to matrix effects. The latter restrains the precise drug quantification through, for example, causing signal suppression. Sophisticated sample preparation and purification utilizing solid-phase extraction was applied to reduce and control matrix effects. A scale-up from vacuum manifold to positive pressure manifold was conducted to meet the demands of high-throughput within a clinical setting. Faced challenges, advances, and experiences in solid-phase extraction are exemplarily presented on the basis of the bioanalytical method development and validation of low-volume samples (50 μL serum). Enalapril, enalaprilat, and benazepril served as sample drugs. The applied sample preparation and extraction successfully reduced the absolute and relative matrix effect to comply with international guidelines. Recoveries ranged from 77 to 104% for enalapril and from 93 to 118% for enalaprilat. The bioanalytical method comprising sample extraction by solid-phase extraction was fully validated according to FDA and EMA bioanalytical guidelines and was used in a Phase I study in 24 volunteers. PMID:25873972

  6. Comparison of blood chemistry values for samples collected from juvenile chinook salmon by three methods

    USGS Publications Warehouse

    Congleton, J.L.; LaVoie, W.J.

    2001-01-01

    Thirteen blood chemistry indices were compared for samples collected by three commonly used methods: caudal transection, heart puncture, and caudal vessel puncture. Apparent biases in blood chemistry values for samples obtained by caudal transection were consistent with dilution with tissue fluids: alanine aminotransferase (ALT), aspartate aminotransferase (AST), lactate dehydrogenase (LDH), creatine kinase (CK), triglyceride, and K+ were increased and Na+ and Cl- were decreased relative to values for samples obtained by caudal vessel puncture. Some enzyme activities (ALT, AST, LDH) and K+ concentrations were also greater in samples taken by heart puncture than in samples taken by caudal vessel puncture. Of the methods tested, caudal vessel puncture had the least effect on blood chemistry values and should be preferred for blood chemistry studies on juvenile salmonids.

  7. 78 FR 31563 - Agency Information Collection Activities; Proposed Collection; Public Comment Request

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-05-24

    ... collecting, validating and verifying information, processing and maintaining information, and disclosing and... Information Collection Activities; Proposed Collection; Public Comment Request AGENCY: Health Resources and... utility of the proposed information collection for the proper performance of the agency's functions, (2...

  8. Macroinvertebrate and algal community sample collection methods and data collected at selected sites in the Eagle River watershed, Colorado, 2000-07

    USGS Publications Warehouse

    Zuellig, Robert E.; Bruce, James F.

    2010-01-01

    State and local agencies are concerned about the effects of increasing urban development and human population growth on water quality and the biological condition of regional streams in the Eagle River watershed. In response to these needs, the U.S. Geological Survey initiated a study in cooperation with the Colorado River Water Conservation District, Eagle County, Eagle River Water and Sanitation District, Upper Eagle Regional Water Authority, Colorado Department of Transportation, City of Aurora, Town of Eagle, Town of Gypsum, Town of Minturn, Town of Vail, Vail Resorts, Colorado Springs Utilities, Denver Water, and the U.S. Department of Agriculture Forest Service. As part of this study, previously collected macroinvertebrate and algal data from the Eagle River watershed were compiled. This report includes macroinvertebrate data collected by the U.S. Geological Survey and(or) the U.S. Department of Agriculture Forest Service from 73 sites from 2000 to 2007 and algal data collected from up to 26 sites between 2000 and 2001 in the Eagle River watershed. Additionally, a brief description of the sample collection methods and data processing procedures are presented.

  9. The Social Interaction Phobia Scale: Continued support for the psychometric validity of the SIPS using clinical and non-clinical samples.

    PubMed

    Menatti, Alison R; Weeks, Justin W; Carleton, R Nicholas; Morrison, Amanda S; Heimberg, Richard G; Hope, Debra A; Blanco, Carlos; Schneier, Franklin R; Liebowitz, Michael R

    2015-05-01

    The present study sought to extend findings supporting the psychometric validity of a promising measure of social anxiety (SA) symptoms, the Social Interaction Phobia Scale (SIPS; Carleton et al., 2009). Analyses were conducted using three samples: social anxiety disorder (SAD) patients, generalized anxiety disorder (GAD) patients, and healthy controls. SIPS scores of SAD patients demonstrated internal consistency and construct validity, and the previously demonstrated three-factor structure of the SIPS was replicated. Further, the SIPS total score uniquely predicted SA symptoms, and SIPS scores were significantly higher for SAD patients than GAD patients or controls. Two cut-off scores that discriminated SAD patients from GAD patients and from healthy controls were identified. The current study is the first to replicate the SIPS three-factor model in a large, treatment-seeking sample of SAD patients and establish a cut-off score discriminating SAD from GAD patients. Findings support the SIPS as a valid, SAD-specific assessment instrument. Copyright © 2015 Elsevier Ltd. All rights reserved.

  10. Occurrence, distribution, and concentrations of selected contaminants in streambed- and suspended-sediment samples collected in Bexar County, Texas, 2007-09

    USGS Publications Warehouse

    Wilson, Jennifer T.

    2011-01-01

    High concentrations of sediment-associated contaminants are typically associated with urban areas such as San Antonio, Texas, in Bexar County, the seventh most populous city in the United States. U.S. Geological Survey personnel periodically collected surficial streambed-sediment samples during 2007-09 and collected suspended-sediment samples from selected streams after storms during 2008 and 2009. All sediment samples were analyzed for major and trace elements, pesticides, polychlorinated biphenyls, and polycyclic aromatic hydrocarbons.

  11. Assessing women's willingness to collect their own cervical samples for HPV testing as part of the ASPIRE cervical cancer screening project in Uganda.

    PubMed

    Mitchell, Sheona; Ogilvie, Gina; Steinberg, Malcolm; Sekikubo, Musa; Biryabarema, Christine; Money, Deborah

    2011-08-01

    To assess women's willingness to collect their own samples for HPV testing as the first part of a screening program for cervical cancer in Uganda. In March and April 2010, trained assistants from Kisenyi interviewed 300 women aged 30 to 65 years who lived and/or worked in this community. Descriptive data and multivariate modeling were used to identify the predictors of the women's willingness to collect their own cervical samples. More than 80% of the 300 participants were willing to collect their own samples. In multivariate modeling, factors positively associated with this willingness were agreement to let outreach workers deliver the necessary swab at their homes (adjusted odds ratio [AOR], 4.10; 95% confidence interval [CI], 1.83-9.18) and willingness to undergo a pelvic examination if the sample was abnormal (AOR, 3.91; 95% CI,1.03-14.90). Factors negatively associated were embarrassment at collecting the sample at home where they lacked privacy (AOR, 0.09; 95% CI, 0.03-0.29) and concern of not collecting the sample properly (AOR, 0.1; 95% CI, 0.05-0.3). Self-collection is an option in impoverished settings in Africa. To improve acceptability, women should be taught how to properly collect their own cervical sample and encouraged to find ways to make the collection less embarrassing. Copyright © 2011 International Federation of Gynecology and Obstetrics. Published by Elsevier Ireland Ltd. All rights reserved.

  12. 78 FR 68846 - Agency Information Collection Activities; Proposed Collection; Public Comment Request

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-11-15

    ... systems for the purpose of collecting, validating and verifying information, processing and maintaining...-30D] Agency Information Collection Activities; Proposed Collection; Public Comment Request AGENCY..., announces plans to submit an Information Collection Request (ICR), described below, to the Office of...

  13. The Health Behavior Checklist: Factor structure in community samples and validity of a revised good health practices scale.

    PubMed

    Hampson, Sarah E; Edmonds, Grant W; Goldberg, Lewis R

    2017-01-01

    This study examined the factor structure and predictive validity of the commonly used multidimensional Health Behavior Checklist. A three-factor structure was found in two community samples that included men and women. The new 16-item Good Health Practices scale and the original Wellness Maintenance scale were the only Health Behavior Checklist scales to be related to cardiovascular and metabolic risk factors. While the other Health Behavior Checklist scales require further validation, the Good Health Practices scale could be used where more objective or longer measures are not feasible.

  14. Use of Latent Class Analysis to define groups based on validity, cognition, and emotional functioning.

    PubMed

    Morin, Ruth T; Axelrod, Bradley N

    Latent Class Analysis (LCA) was used to classify a heterogeneous sample of neuropsychology data. In particular, we used measures of performance validity, symptom validity, cognition, and emotional functioning to assess and describe latent groups of functioning in these areas. A data-set of 680 neuropsychological evaluation protocols was analyzed using a LCA. Data were collected from evaluations performed for clinical purposes at an urban medical center. A four-class model emerged as the best fitting model of latent classes. The resulting classes were distinct based on measures of performance validity and symptom validity. Class A performed poorly on both performance and symptom validity measures. Class B had intact performance validity and heightened symptom reporting. The remaining two Classes performed adequately on both performance and symptom validity measures, differing only in cognitive and emotional functioning. In general, performance invalidity was associated with worse cognitive performance, while symptom invalidity was associated with elevated emotional distress. LCA appears useful in identifying groups within a heterogeneous sample with distinct performance patterns. Further, the orthogonal nature of performance and symptom validities is supported.

  15. Concentration and characteristics of depleted uranium in water, air and biological samples collected in Serbia and Montenegro.

    PubMed

    Jia, Guogang; Belli, Maria; Sansone, Umberto; Rosamilia, Silvia; Gaudino, Stefania

    2005-09-01

    During the Balkan conflicts, in 1995 and 1999, depleted uranium (DU) rounds were employed and were left in the battlefield. Health concern is related to the risk arising from contamination of the environment with DU penetrators and dust. In order to evaluate the impact of DU on the environment and population in Serbia and Montenegro, radiological surveys of DU in water, air and biological samples were carried out over the period 27 October-5 November 2001. The uranium isotopic concentrations in biological samples collected in Serbia and Montenegro, mainly lichens and barks, were found to be in the range of 0.67-704 Bqkg(-1) for (238)U, 0.48-93.9 Bqkg(-1) for (234)U and 0.02-12.2 Bqkg(-1) for (235)U, showing uranium levels to be higher than in the samples collected at the control sites. Moreover, (236)U was detectable in some of the samples. The isotopic ratios of (234)U/(238)U showed DU to be detectable in many biological samples at all examined sites, especially in Montenegro, indicating widespread ground-surface DU contamination, albeit at very low level. The uranium isotopic concentrations in air obtained from the air filter samples collected in Serbia and Montenegro were found to be in the range of 1.99-42.1 microBqm(-3) for (238)U, 0.96-38.0 microBqm(-3) for (234)U, and 0.05-1.83 microBqm(-3) for (235)U, being in the typical range of natural uranium values. Thus said, most of the air samples are DU positive, this fact agreeing well with the widespread DU contamination detected in the biological samples. The uranium concentrations in water samples collected in Serbia and Montenegro were found to be in the range of 0.40-21.9 mBql(-1) for (238)U, 0.27-28.1 mBql(-1) for (234)U, and 0.01-0.88 mBql(-1) for (235)U, these values being much lower than those in mineral water found in central Italy and below the WHO guideline for drinking water. From a radiotoxicological point of view, at this moment there is no significant radiological risk related to these investigated

  16. Potential and Challenges in Collecting Social and Behavioral Data on Adolescent Alcohol Norms: Comparing Respondent-Driven Sampling and Web-Based Respondent-Driven Sampling

    PubMed Central

    Hildebrand, Janina; Burns, Sharyn; Zhao, Yun; Lobo, Roanna; Howat, Peter; Allsop, Steve

    2015-01-01

    Background Respondent-driven sampling (RDS) is a method successfully used to research hard-to-access populations. Few studies have explored the use of the Internet and social media with RDS, known as Web-based RDS (WebRDS). This study explored the use of combining both “traditional” RDS and WebRDS to examine the influences on adolescent alcohol use. Objective This paper reports on the recruitment processes and the challenges and enablers of both RDS and WebRDS. It details comparative recruitment data and provides a summary of the utility of both methods for recruiting adolescents to participate in an online survey investigating youth alcohol norms. Methods Process evaluation data collected from research staff throughout the study were used to assess the challenges and solutions of RDS and WebRDS. Pearson chi-square test (Fisher’s exact test if applicable) was used to compare the differences in sociodemographics and drinking behavior between data collected by RDS and WebRDS. Results Of the total sample (N=1012), 232 adolescents were recruited by RDS and 780 by WebRDS. A significantly larger proportion of Aboriginal or Torres Strait Islander (P<.001) participants who spoke English as their main language at home (P=.03), and of middle and lower socioeconomic status (P<.001) was found in the RDS sample. The RDS sample was also found to have a higher occurrence of past 7-day drinking (P<.001) and past 7-day risky drinking (P=.004). No significant differences in gender, age, past month alcohol use, and lifetime alcohol use were observed between the RDS and WebRDS samples. This study revealed RDS and WebRDS used similar lengths of chains for recruiting participants; however, WebRDS conducted a faster rate of recruitment at a lower average cost per participant compared to RDS. Conclusions Using WebRDS resulted in significant improvements in the recruitment rate and was a more effective and efficient use of resources than the traditional RDS method. However, Web

  17. Nutrition: blood sample collection

    NASA Image and Video Library

    2007-03-20

    ISS014-E-17550 (20 March 2007) --- Astronaut Michael E. Lopez-Alegria, Expedition 14 commander and NASA space station science officer, prepares to insert a test sample in the Minus Eighty Degree Laboratory Freezer for ISS (MELFI) as part of the Nutritional Status Assessment (NUTRITION) experiment in the Destiny laboratory of the International Space Station. MELFI is a low temperature freezer facility with nominal operating temperatures of -80, -26 and +4 degrees Celsius that will preserve experiment materials over long periods.

  18. Nutrition: blood sample collection

    NASA Image and Video Library

    2007-03-20

    ISS014-E-17547 (20 March 2007) --- Astronaut Michael E. Lopez-Alegria, Expedition 14 commander and NASA space station science officer, prepares to insert a test sample in the Minus Eighty Degree Laboratory Freezer for ISS (MELFI) as part of the Nutritional Status Assessment (NUTRITION) experiment in the Destiny laboratory of the International Space Station. MELFI is a low temperature freezer facility with nominal operating temperatures of -80, -26 and +4 degrees Celsius that will preserve experiment materials over long periods.

  19. Validation study of the Tanaka and Kawasaki equations to estimate the daily sodium excretion by a spot urine sample.

    PubMed

    Mill, José Geraldo; Rodrigues, Sérgio Lamêgo; Baldo, Marcelo Perim; Malta, Deborah Carvalho; Szwarcwald, Celia Landmann

    2015-12-01

    To validate Tanaka and Kawasaki's formulas to calculate the salt intake by the sodium/creatinine ratio in spot of urine. Two hundred and seventy two adults (20 - 69 years old; 52.6% women) with 24 h urine collection and two urinary spots collected on the same day (while fasting - spot 1 - or not fasting - spot 2). Anthropometry, blood pressure and fasting blood were measured on the same day. The analysis of agreement between salt consumption measured in the 24 h urine test and urinary spots were determined by the Pearson's correlation (r) and the Bland & Altman method. The mean salt consumption measured by the 24 h sodium excretion was 10.4 ± 5.3 g/day. The correlation between the measured 24 h sodium excretion and the estimation based on spots 1 and 2, respectively, was only moderated according to Tanaka (r = 0.51 and r = 0.55; p < 0.001) and to Kawasaki (r = 0.52 and r = 0.54; p < 0.001). We observed an increasing underestimation of salt consumption by Tanaka to increasing salt consumption and conversely, an overestimation of consumption by the Kawasaki formula. The estimation of salt consumption (difference between measured and calculated salt consumption lower than 1 g/day) was adequate only when the consumption was between 9 - 12 g/day (Tanaka) and 12 - 18 g/day (Kawasaki). Spot urine sampling is adequate to estimate salt consumption only among individuals with an actual consumption near the population mean.

  20. Validating the cross-cultural factor structure and invariance property of the Insomnia Severity Index: evidence based on ordinal EFA and CFA.

    PubMed

    Chen, Po-Yi; Yang, Chien-Ming; Morin, Charles M

    2015-05-01

    The purpose of this study is to examine the factor structure of the Insomnia Severity Index (ISI) across samples recruited from different countries. We tried to identify the most appropriate factor model for the ISI and further examined the measurement invariance property of the ISI across samples from different countries. Our analyses included one data set collected from a Taiwanese sample and two data sets obtained from samples in Hong Kong and Canada. The data set collected in Taiwan was analyzed with ordinal exploratory factor analysis (EFA) to obtain the appropriate factor model for the ISI. After that, we conducted a series of confirmatory factor analyses (CFAs), which is a special case of the structural equation model (SEM) that concerns the parameters in the measurement model, to the statistics collected in Canada and Hong Kong. The purposes of these CFA were to cross-validate the result obtained from EFA and further examine the cross-cultural measurement invariance of the ISI. The three-factor model outperforms other models in terms of global fit indices in Taiwan's population. Its external validity is also supported by confirmatory factor analyses. Furthermore, the measurement invariance analyses show that the strong invariance property between the samples from different cultures holds, providing evidence that the ISI results obtained in different cultures are comparable. The factorial validity of the ISI is stable in different populations. More importantly, its invariance property across cultures suggests that the ISI is a valid measure of the insomnia severity construct across countries. Copyright © 2014 Elsevier B.V. All rights reserved.