Sample records for validated stability-indicating hplc

  1. Development and validation of a stability indicating HPLC method for determination of lisinopril, lisinopril degradation product and parabens in the lisinopril extemporaneous formulation.

    PubMed

    Beasley, Christopher A; Shaw, Jessica; Zhao, Zack; Reed, Robert A

    2005-03-09

    The purpose of the research described herein was to develop and validate a stability-indicating HPLC method for lisinopril, lisinopril degradation product (DKP), methyl paraben and propyl paraben in a lisinopril extemporaneous formulation. The method developed in this report is selective for the components listed above, in the presence of the complex and chromatographically rich matrix presented by the Bicitra and Ora-Sweet SF formulation diluents. The method was also shown to have adequate sensitivity with a detection limit of 0.0075 microg/mL (0.03% of lisinopril method concentration). The validation elements investigated showed that the method has acceptable specificity, recovery, linearity, solution stability, and method precision. Acceptable robustness indicates that the assay method remains unaffected by small but deliberate variations, which are described in ICH Q2A and Q2B guidelines.

  2. Stability-indicating HPLC-DAD methods for determination of two binary mixtures: Rabeprazole sodium-mosapride citrate and rabeprazole sodium-itopride hydrochloride.

    PubMed

    El-Fatatry, Hamed M; Mabrouk, Mokhtar M; Hewala, Ismail I; Emam, Ehab H

    2014-08-01

    Two selective stability-indicating HPLC methods are described for determination of rabeprazole sodium (RZ)-mosapride citrate (MR) and RZ-itopride hydrochloride (IO) mixtures in the presence of their ICH-stress formed degradation products. Separations were achieved on X-Bridge C18 column using two mobile phases: the first for RZ-MR mixture consisted of acetonitrile: 0.025 M KH 2 PO 4 solution: TEA (30:69:1 v/v; pH 7.0); the second for RZ-IO mixture was at ratio of 25:74:1 (v/v; pH 9.25). The detection wavelength was 283 nm. The two methods were validated and validation acceptance criteria were met in all cases. Peak purity testing using contrast angle theory, relative absorbance and log  A versus the wavelengths plots were presented. The % recoveries of the intact drugs were between 99.1% and 102.2% with RSD% values less than 1.6%. Application of the proposed HPLC methods indicated that the methods could be adopted to follow the stability of their formulations.

  3. Development and validation of a novel stability-indicating HPLC method for the simultaneous assay of betamethasone-17-valerate, fusidic acid, potassium sorbate, methylparaben and propylparaben in a topical cream preparation.

    PubMed

    Byrne, Jonathan; Velasco-Torrijos, Trinidad; Reinhardt, Robert

    2014-08-05

    A novel stability-indicating reversed phase high performance liquid chromatographic (RP-HPLC) method for the simultaneous assay of betamethasone-17-valerate, fusidic acid and potassium sorbate as well as methyl- and propylparaben in a topical cream preparation has been developed. A 100mm×3.0mm ID. Ascentis Express C18 column maintained at 30°C and UV detection at 240nm were used. A gradient programme was employed at a flow-rate of 0.75ml/min. Mobile phase A comprised of an 83:17 (v/v) mixture of acetonitrile and methanol and mobile phase B of a 10g/l solution of 85% phosphoric acid in purified water. The method has been validated according to current International Conference on Harmonisation (ICH) guidelines and applied during formulation development and stability studies. The procedure has been shown to be stability-indicating for the topical cream. Copyright © 2014 Elsevier B.V. All rights reserved.

  4. Development and Validation of a Stability-Indicating Assay of Etofenamate by RP-HPLC and Characterization of Degradation Products

    PubMed Central

    Peraman, Ramalingam; Nayakanti, Devanna; Dugga, Hari Hara Theja; Kodikonda, Sudhakara

    2013-01-01

    A validated stability-indicating RP-HPLC method for etofenamate (ETF) was developed by separating its degradation products on a C18 (250 mm × 4.6 mm 5 μm) Qualisil BDS column using a phosphate buffer (pH-adjusted to 6.0 with orthophosphoric acid) and methanol in the ratio of 20:80 % v/v as the mobile phase at a flow rate of 1.0 mL/min. The column effluents were monitored by a photodiode array detector set at 286 nm. The method was validated in terms of specificity, linearity, accuracy, precision, detection limit, quantification limit, and robustness. Forced degradation of etofenamate was carried out under acidic, basic, thermal, photo, and peroxide conditions and the major degradation products of acidic and basic degradation were isolated and characterized by 1H-NMR, 13C-NMR, and mass spectral studies. The mass balance of the method varied between 92–99%. PMID:24482770

  5. Validation and Uncertainty Estimation of an Ecofriendly and Stability-Indicating HPLC Method for Determination of Diltiazem in Pharmaceutical Preparations

    PubMed Central

    Sadeghi, Fahimeh; Navidpour, Latifeh; Bayat, Sima; Afshar, Minoo

    2013-01-01

    A green, simple, and stability-indicating RP-HPLC method was developed for the determination of diltiazem in topical preparations. The separation was based on a C18 analytical column using a mobile phase consisted of ethanol: phosphoric acid solution (pH = 2.5) (35 : 65, v/v). Column temperature was set at 50°C and quantitation was achieved with UV detection at 240 nm. In forced degradation studies, the drug was subjected to oxidation, hydrolysis, photolysis, and heat. The method was validated for specificity, selectivity, linearity, precision, accuracy, and robustness. The applied procedure was found to be linear in diltiazem concentration range of 0.5–50 μg/mL (r 2 = 0.9996). Precision was evaluated by replicate analysis in which % relative standard deviation (RSD) values for areas were found below 2.0. The recoveries obtained (99.25%–101.66%) ensured the accuracy of the developed method. The degradation products as well as the pharmaceutical excipients were well resolved from the pure drug. The expanded uncertainty (5.63%) of the method was also estimated from method validation data. Accordingly, the proposed validated and sustainable procedure was proved to be suitable for routine analyzing and stability studies of diltiazem in pharmaceutical preparations. PMID:24163778

  6. Development and validation of stability indicating HPLC methods for related substances and assay analyses of amoxicillin and potassium clavulanate mixtures.

    PubMed

    Bellur Atici, Esen; Yazar, Yücel; Ağtaş, Çağan; Ridvanoğlu, Nurten; Karlığa, Bekir

    2017-03-20

    Antibacterial combinations consisting of the semisynthetic antibiotic amoxicillin (amox) and the β-lactamase inhibitor potassium clavulanate (clav) are commonly used and several chromatographic methods were reported for their quantification in mixtures. In the present work, single HPLC method for related substances analyses of amoxicillin and potassium clavulanate mixtures was developed and validated according to international conference on harmonization (ICH) guidelines. Eighteen amoxicillin and six potassium clavulanate impurities were successfully separated from each other by using triple gradient elution using a Thermo Hypersil Zorbax BDS C18 (250 mm×4.6mm, 3μm) column with 50μL injection volumes at a wavelength of 215nm. Commercially unavailable impurities were formed by degradation of amoxicillin and potassium clavulanate, identified by LC-MS studies and used during analytical method development and validation studies. Also, process related amoxicillin impurity-P was synthesized and characterized by using nuclear magnetic resonance (NMR) and mass spectroscopy (MS) for the first time. As complementary of this work, an assay method for amoxicillin and potassium clavulanate mixtures was developed and validated; stress-testing and stability studies of amox/clav mixtures was carried out under specified conditions according to ICH and analyzed by using validated stability-indicating assay and related substances methods. Copyright © 2016 Elsevier B.V. All rights reserved.

  7. Stability-Indicating TLC-Densitometric and HPLC Methods for the Simultaneous Determination of Piracetam and Vincamine in the Presence of Their Degradation Products.

    PubMed

    Ahmed, Amal B; Abdelrahman, Maha M; Abdelwahab, Nada S; Salama, Fathy M

    2016-11-01

    Newly established TLC-densitometric and RP-HPLC methods were developed and validated for the simultaneous determination of Piracetam (PIR) and Vincamine (VINC) in their pharmaceutical formulation and in the presence of PIR and VINC degradation products, PD and VD, respectively. The proposed TLC-densitometric method is based on the separation and quantitation of the studied components using a developing system that consists of chloroform-methanol-glacial acetic acid-triethylamine (8 + 2 + 0.1 + 0.1, v/v/v/v) on TLC silica gel 60 F254 plates, followed by densitometric scanning at 230 nm. On the other hand, the developed RP-HPLC method is based on the separation of the studied components using an isocratic elution of 0.05 M KH2PO4 (containing 0.1% triethylamine adjusted to pH 3 with orthophosphoric acid)-methanol (95 + 5, v/v) on a C8 column at a flow rate of 1 mL/min with diode-array detection at 230 nm. The developed methods were validated according to International Conference on Harmonization guidelines and demonstrated good accuracy and precision. Moreover, the developed TLC-densitometric and RP-HPLC methods are suitable as stability-indicating assay methods for the simultaneous determination of PD and VD either in bulk powder or pharmaceutical formulation. The results were statistically compared with those obtained by the reported RP-HPLC method using t- and F-tests.

  8. Stability Indicating Reverse Phase HPLC Method for Estimation of Rifampicin and Piperine in Pharmaceutical Dosage Form.

    PubMed

    Shah, Umang; Patel, Shraddha; Raval, Manan

    2018-01-01

    High performance liquid chromatography is an integral analytical tool in assessing drug product stability. HPLC methods should be able to separate, detect, and quantify the various drug-related degradants that can form on storage or manufacturing, plus detect any drug-related impurities that may be introduced during synthesis. A simple, economic, selective, precise, and stability-indicating HPLC method has been developed and validated for analysis of Rifampicin (RIFA) and Piperine (PIPE) in bulk drug and in the formulation. Reversed-phase chromatography was performed on a C18 column with Buffer (Potassium Dihydrogen Orthophosphate) pH 6.5 and Acetonitrile, 30:70), (%, v/v), as mobile phase at a flow rate of 1 mL min-1. The detection was performed at 341 nm and sharp peaks were obtained for RIFA and PIPE at retention time of 3.3 ± 0.01 min and 5.9 ± 0.01 min, respectively. The detection limits were found to be 2.385 ng/ml and 0.107 ng/ml and quantification limits were found to be 7.228ng/ml and 0.325ng/ml for RIFA and PIPE, respectively. The method was validated for accuracy, precision, reproducibility, specificity, robustness, and detection and quantification limits, in accordance with ICH guidelines. Stress study was performed on RIFA and PIPE and it was found that these degraded sufficiently in all applied chemical and physical conditions. Thus, the developed RP-HPLC method was found to be suitable for the determination of both the drugs in bulk as well as stability samples of capsule containing various excipients. Copyright© Bentham Science Publishers; For any queries, please email at epub@benthamscience.org.

  9. Development and validation of a stability-indicating RP-HPLC method for determination of atomoxetine hydrochloride in tablets.

    PubMed

    Patel, Sejal K; Patel, Natvarlal J

    2010-01-01

    This paper describes the development of a stability-indicating RP-HPLC method for the determination of atomoxetine hydrochloride (ATX) in the presence of its degradation products generated from forced decomposition studies. The drug substance was subjected to stress conditions of acid, base, oxidation, wet heat, dry heat, and photodegradation. In stability tests, the drug was susceptible to acid, base, oxidation, and dry and wet heat degradation. It was found to be stable under the photolytic conditions tested. The drug was successfully separated from the degradation products formed under stress conditions on a Phenomenex C18 column (250 x 4.6 mm id, 5 microm particle size) by using acetonitrile-methanol-0.032 M ammonium acetate (55 + 05 + 40, v/v/v) as the mobile phase at 1.0 mL/min and 40 degrees C. Photodiode array detection at 275 nm was used for quantitation after RP-HPLC over the concentration range of 0.5-5 microg/mL with a mean recovery of 100.8 +/- 0.4% for ATX. Statistical analysis demonstrated that the method is repeatable, specific, and accurate for the estimation of ATX. Because the method effectively separates the drug from its degradation products, it can be used as a stability-indicating method.

  10. Development and Validation of a Stability-Indicating RP-HPLC Method for Duloxetine Hydrochloride in its Bulk and Tablet Dosage Form

    PubMed Central

    Chhalotiya, Usmangani K.; Bhatt, Kashyap K.; Shah, Dimal A.; Baldania, Sunil L.

    2010-01-01

    The objective of the present work was to develop a stability-indicating RP-HPLC method for duloxetine hydrochloride (DUL) in the presence of its degradation products generated from forced decomposition studies. The drug substance was found to be susceptible to stress conditions of acid hydrolysis. The drug was found to be stable to dry heat, photodegradation, oxidation and basic condition attempted. Successful separation of the drug from the degradation products formed under acidic stress conditions was achieved on a Hypersil C-18 column (250 mm × 4.6 mm id, 5μm particle size) using acetonitrile: 0.01 M potassium dihydrogen phosphate buffer (pH 5.4 adjusted with orthophosphoric acid) (50:50, v/v) as the mobile phase at a flow rate of 1.0 ml/min. Quantification was achieved with photodiode array detection at 229 nm over the concentration range 1–25 μg/ml with range of recovery 99.8–101.3 % for DUL by the RP-HPLC method. Statistical analysis proved the method to be repeatable, specific, and accurate for estimation of DUL. It can be used as a stability-indicating method due to its effective separation of the drug from its degradation products, PMID:21179321

  11. Stability of extemporaneously prepared preservative-free prochlorperazine nasal spray.

    PubMed

    Yellepeddi, Venkata K

    2018-01-01

    The stability of an extemporaneously prepared preservative-free prochlorperazine 5-mg/mL nasal spray was evaluated. The preservative-free prochlorperazine nasal spray was prepared by adding 250 mg of prochlorperazine edisylate to 50 mL of citrate buffer in a low-density polyethylene nasal spray bottle. A stability-indicating high-performance liquid chromatography (HPLC) method was developed and validated using the major degradant prochlorperazine sulfoxide and by performing forced-degradation studies. For chemical stability studies, 3 100-μL samples of the preservative-free prochlorperazine from 5 nasal spray bottles stored at room temperature were collected at days 0, 20, 30, 45, and 60 and were assayed in triplicate using the stability-indicating HPLC method. Microbiological testing involved antimicrobial effectiveness testing based on United States Pharmacopeia ( USP ) chapter 51 and quantitative microbiological enumeration of aerobic bacteria, yeasts, and mold based on USP chapter 61. Samples for microbiological testing were collected at days 0, 30, and 60. The stability-indicating HPLC method clearly identified the degradation product prochlorperazine sulfoxide without interference from prochlorperazine. All tested solutions retained over 90% of the initial prochlorperazine concentration for the 60-day study period. There were no detectable changes in color, pH, and viscosity in any sample. There was no growth of bacteria, yeast, and mold for 60 days in all samples tested. An extemporaneously prepared preservative-free nasal spray solution of prochlorperazine edisylate 5 mg/mL was physically, chemically, and microbiologically stable for 60 days when stored at room temperature in low-density polyethylene bottles. Copyright © 2018 by the American Society of Health-System Pharmacists, Inc. All rights reserved.

  12. Development and validation of stability indicating method for the quantitative determination of venlafaxine hydrochloride in extended release formulation using high performance liquid chromatography

    PubMed Central

    Kaur, Jaspreet; Srinivasan, K. K.; Joseph, Alex; Gupta, Abhishek; Singh, Yogendra; Srinivas, Kona S.; Jain, Garima

    2010-01-01

    Objective: Venlafaxine,hydrochloride is a structurally novel phenethyl bicyclic antidepressant, and is usually categorized as a serotonin–norepinephrine reuptake inhibitor (SNRI) but it has been referred to as a serotonin–norepinephrine–dopamine reuptake inhibitor. It inhibits the reuptake of dopamine. Venlafaxine HCL is widely prescribed in the form of sustained release formulations. In the current article we are reporting the development and validation of a fast and simple stability indicating, isocratic high performance liquid chromatographic (HPLC) method for the determination of venlafaxine hydrochloride in sustained release formulations. Materials and Methods: The quantitative determination of venlafaxine hydrochloride was performed on a Kromasil C18 analytical column (250 × 4.6 mm i.d., 5 μm particle size) with 0.01 M phosphate buffer (pH 4.5): methanol (40: 60) as a mobile phase, at a flow rate of 1.0 ml/min. For HPLC methods, UV detection was made at 225 nm. Results: During method validation, parameters such as precision, linearity, accuracy, stability, limit of quantification and detection and specificity were evaluated, which remained within acceptable limits. Conclusions: The method has been successfully applied for the quantification and dissolution profiling of Venlafaxine HCL in sustained release formulation. The method presents a simple and reliable solution for the routine quantitative analysis of Venlafaxine HCL. PMID:21814426

  13. Development and validation of a rapid stability indicating HPLC-method using monolithic stationary phase and two spectrophotometric methods for determination of antihistaminic acrivastine in capsules

    NASA Astrophysics Data System (ADS)

    Gouda, Ayman A.; Hashem, Hisham; Jira, Thomas

    2014-09-01

    Simple, rapid and accurate high performance liquid chromatographic (HPLC) and spectrophotometric methods are described for determination of antihistaminic acrivastine in capsules. The first method (method A) is based on accurate, sensitive and stability indicating chromatographic separation method. Chromolith® Performance RP-18e column, a relatively new packing material consisting of monolithic rods of highly porous silica, was used as stationary phase applying isocratic binary mobile phase of ACN and 25 mM NaH2PO4 pH 4.0 in the ratio of 22.5:77.5 at flow rate of 5.0 mL/min and 40 °C. A diode array detector was used at 254 nm for detection. The elution time of acrivastine was found to be 2.080 ± 0.032. The second and third methods (methods B and C) are based on the oxidation of acrivastine with excess N-bromosuccinimide (NBS) and determination of the unconsumed NBS with, metol-sulphanilic acid (λmax: 520 nm) or amaranth dye (λmax: 530 nm). The reacted oxidant corresponds to the drug content. Beer’s law is obeyed over the concentration range 1.563-50, 2.0-20 and 1.0-10 μg mL-1 for methods A, B and C, respectively. The limits of detection and quantitation were 0.40, 0.292 and 0.113 μg mL-1 and 0.782, 0.973 and 0.376 μg mL-1 for methods A, B and C, respectively. The HPLC method was validated for system suitability, linearity, precision, limits of detection and quantitation, specificity, stability and robustness. Stability tests were done through exposure of the analyte solution for four different stress conditions and the results indicate no interference of degradants with HPLC-method. The proposed methods was favorably applied for determination of acrivastine in capsules formulation. Statistical comparison of the obtained results from the analysis of the studied drug to those of the reported method using t- and F-tests showed no significant difference between them.

  14. New Stability Indicating RP-HPLC Method for the Estimation of Cefpirome Sulphate in Bulk and Pharmaceutical Dosage Forms.

    PubMed

    Rao, Kareti Srinivasa; Kumar, Keshar Nargesh; Joydeep, Datta

    2011-01-01

    A simple stability indicating reversed-phase HPLC method was developed and subsequently validated for estimation of Cefpirome sulphate (CPS) present in pharmaceutical dosage forms. The proposed RP-HPLC method utilizes a LiChroCART-Lichrosphere100, C18 RP column (250 mm × 4mm × 5 μm) in an isocratic separation mode with mobile phase consisting of methanol and water in the proportion of 50:50 % (v/v), at a flow rate 1ml/min, and the effluent was monitored at 270 nm. The retention time of CPS was 2.733 min and its formulation was exposed to acidic, alkaline, photolytic, thermal and oxidative stress conditions, and the stressed samples were analyzed by the proposed method. The described method was linear over a range of 0.5-200μg/ml. The percentage recovery was 99.46. F-test and t-test at 95% confidence level were used to check the intermediate precision data obtained under different experimental setups; the calculated value was found to be less than the critical value.

  15. Development and validation of a stability-indicating RP-HPLC method for assay of betamethasone and estimation of its related compounds.

    PubMed

    Fu, Qiang; Shou, Minshan; Chien, Dwight; Markovich, Robert; Rustum, Abu M

    2010-02-05

    Betamethasone (9alpha-fluoro-16beta-methylprednisolone) is one of the members of the corticosteriod family of active pharmaceutical ingredient (API), which is widely used as an anti-inflammatory agent and also as a starting material to manufacture various esters of betamethasone. A stability-indicating reverse-phase high performance liquid chromatography (RP-HPLC) method has been developed and validated which can separate and accurately quantitate low levels of 26 betamethasone related compounds. The stability-indicating capability of the method was demonstrated through adequate separation of all potential betamethasone related compounds from betamethasone and also from each other that are present in aged and stress degraded betamethasone stability samples. Chromatographic separation of betamethasone and its related compounds was achieved by using a gradient elution at a flow rate of 1.0mL/min on a ACE 3 C18 column (150mmx4.6mm, 3microm particle size, 100A pore size) at 40 degrees C. Mobile phase A of the gradient was 0.1% methanesulfonic acid in aqueous solution and mobile phase B was a mixture of tert-butanol and 1,4-dioxane (7:93, v/v). UV detection at 254nm was employed to monitor the analytes. For betamethasone 21-aldehyde, the QL and DL were 0.02% and 0.01% respectively. For betamethasone and the rest of the betamethasone related compounds, the QL and DL were 0.05% and 0.02%. The precision of betamethasone assay is 0.6% and the accuracy of betamethasone assay ranged from 98.1% to 99.9%.

  16. Validated stability-indicating HPLC method for paricalcitol in pharmaceutical dosage form according to ICH guidelines: application to stability studies.

    PubMed

    Ortega, Raquel; Navas, Natalia; Salmerón, Antonio; Cabeza, José; Capitán-Vallvey, Luís F

    2011-01-01

    A stability-indicating HPLC method with diode array detection for the determination of paricalcitol, a synthetic vitamin D2 analog, was developed. Analytical parameters were studied according to International Conference on Harmonization guidelines. A C18 column (250 x 4.6 mm, 5 microm particle size) maintained at 25 degrees C was used as the stationary phase, and acetonitrile-water (70 + 30, v/v) as the mobile phase. Chromatograms were recorded at 250 nm. In forced degradation studies, the effects of acid, base, oxidation, temperature, and UV light were investigated and showed no interference with the drug peak. The method was found to be linear (r = 0.9989) at concentrations ranging from 0.6 to 10.0 mg/L paricalcitol, precise (repeatability and intermediate precision estimated as RSD less than 3.5%), accurate (recoveries higher than 95%), specific, and robust. The LOD and LOQ were 0.6 and 0.2 mg/L, respectively. The validated method was used for paricalcitol determination in a formal stability study of its pharmaceutical dosage form in preloaded syringes. The stability of a diluted solution of its pharmaceutical form in Viaflo bags was also tested. The results showed that paricalcitol was stable in preloaded syringes during a period of 30 days from preparation in the different storage conditions tested (room temperature without protection from daylight and 4.4 degrees C with protection from daylight). On the contrary, paricalcitol was quickly lost when stored in Viaflo bags by adsorption onto the walls of the container.

  17. Comparative Assessment of the Effect of Hyper-glycosylation on the Pattern and Kinetics of Degradation of Darbepoetin Alfa using a Stability-Indicating Orthogonal Testing Protocol.

    PubMed

    Moenes, Eman M; Al-Ghobashy, Medhat A; Mohamed, Abeer A; Salem, Maissa Y

    2018-01-01

    Darbepoetin alfa (DA); hyper-glycosylated Erythropoietin alfa (EPO) is an essential treatment of anemia in patients with chronic kidney failure and cancer. In this study, DA and EPO were subjected to physicochemical stress factors that might be encountered during production, transport and storage (pH, temperature, agitation, repeated freeze-thaw and oxidation). An orthogonal stability-indicating assay protocol comprised of SE-HPLC, RP-HPLC, ELISA and SDS-PAGE was developed and validated to investigate the effect of further glycosylation of DA on the pattern and kinetics of degradation. Results showed a relatively higher stability and lower tendency to form high molecular weight aggregates in the case of DA when compared to EPO, under equivalent stress conditions. Dimers and aggregates were formed for both drugs across the whole pH range and following incubation at temperatures higher than 2-8°C or repeated freeze/thaw. The same observation was noted upon agitation of standard samples prepared in the formulation buffers at high speed and upon oxidation with hydrogen peroxide. The agreement between SE-HPLC, supported with spectral purity data and ELISA confirmed the specificity of both techniques for the intact drugs. Results of RP-HPLC and SDS-PAGE indicated that dimerization occurred through disulfide and bi-tyrosine covalent bonds in the case of pH and oxidation, respectively. It was evident that aggregation was significantly suppressed upon increasing the glycan size and under any of the studied stress factors loss of the glycan has not been observed. These observations supported with the slow kinetics of degradation confirmed the superiority of glyco-engineering over chemical pegylation to enhance the stability of EPO. Formation of such potentially immunogenic product-related impurities at all tested stress factors confirmed the need for orthogonal testing protocols to investigate the complex pattern of degradation of such sensitive products. Copyright © 2017 Elsevier B.V. All rights reserved.

  18. Storage stability study of porcine hepatic and intestinal cytochrome P450 isoenzymes by use of a newly developed and fully validated highly sensitive HPLC-MS/MS method.

    PubMed

    Schelstraete, Wim; Devreese, Mathias; Croubels, Siska

    2018-02-01

    Microsomes are an ideal medium to investigate cytochrome P450 (CYP450) enzyme-mediated drug metabolism. However, before microsomes are prepared, tissues can be stored for a long time. Studies about the stability of these enzymes in porcine hepatic and intestinal tissues upon storage are lacking. To be able to investigate CYP450 stability in microsomes prepared from these tissues, a highly sensitive and rapid HPLC-MS/MS method for the simultaneous determination of six CYP450 metabolites in incubation medium was developed and validated. The metabolites, paracetamol (CYP1A), 7-hydroxy-coumarin (CYP2A), 1-hydroxy-midazolam (CYP3A), 4-hydroxy-tolbutamide (CYP2C), dextrorphan (CYP2D), and 6-hydroxy-chlorzoxazone (CYP2E) were extracted with ethyl acetate at pH 1.0, followed by evaporation and separation on an Agilent Zorbax Eclipse Plus C18 column. The method was fully validated in a GLP-compliant laboratory according to European guidelines and was highly sensitive (LOQ = 0.25-2.5 ng/mL), selective, had good precision (RSD-within, 1.0-9.1%; RSD-between, 1.0-18.4%) and accuracy (within-run, 83.3-102%; between-run, 78.5-102%), and showed no relative signal suppression and enhancement. Consequently, this method was applied to study the stability of porcine hepatic and intestinal CYP450 isoenzymes when tissues were stored at - 80 °C. The results indicate that porcine CYP450 isoenzymes are stable in tissues at least up to 4 months when snap frozen and stored at - 80 °C. Moreover, the results indicate differences in porcine CYP450 stability compared to rat, rabbit, and fish CYP450, as observed by other research groups, hence stressing the importance to investigate the CYP450 stability of a specific species.

  19. Stress Degradation Studies on Varenicline Tartrate and Development of a Validated Stability-Indicating HPLC Method

    PubMed Central

    Pujeri, Sudhakar S.; Khader, Addagadde M. A.; Seetharamappa, Jaldappagari

    2012-01-01

    A simple, rapid and stability-indicating reversed-phase liquid chromatographic method was developed for the assay of varenicline tartrate (VRT) in the presence of its degradation products generated from forced decomposition studies. The HPLC separation was achieved on a C18 Inertsil column (250 mm × 4.6 mm i.d. particle size is 5 μm) employing a mobile phase consisting of ammonium acetate buffer containing trifluoroacetic acid (0.02M; pH 4) and acetonitrile in gradient program mode with a flow rate of 1.0 mL min−1. The UV detector was operated at 237 nm while column temperature was maintained at 40 °C. The developed method was validated as per ICH guidelines with respect to specificity, linearity, precision, accuracy, robustness and limit of quantification. The method was found to be simple, specific, precise and accurate. Selectivity of the proposed method was validated by subjecting the stock solution of VRT to acidic, basic, photolysis, oxidative and thermal degradation. The calibration curve was found to be linear in the concentration range of 0.1–192 μg mL−1 (R2 = 0.9994). The peaks of degradation products did not interfere with that of pure VRT. The utility of the developed method was examined by analyzing the tablets containing VRT. The results of analysis were subjected to statistical analysis. PMID:22396908

  20. Spectroscopic characterization and quantitative determination of atorvastatin calcium impurities by novel HPLC method

    NASA Astrophysics Data System (ADS)

    Gupta, Lokesh Kumar

    2012-11-01

    Seven process related impurities were identified by LC-MS in the atorvastatin calcium drug substance. These impurities were identified by LC-MS. The structure of impurities was confirmed by modern spectroscopic techniques like 1H NMR and IR and physicochemical studies conducted by using synthesized authentic reference compounds. The synthesized reference samples of the impurity compounds were used for the quantitative HPLC determination. These impurities were detected by newly developed gradient, reverse phase high performance liquid chromatographic (HPLC) method. The system suitability of HPLC analysis established the validity of the separation. The analytical method was validated according to International Conference of Harmonization (ICH) with respect to specificity, precision, accuracy, linearity, robustness and stability of analytical solutions to demonstrate the power of newly developed HPLC method.

  1. Stability of Cyclophosphamide in Extemporaneous Oral Suspensions

    PubMed Central

    Kennedy, Rachel; Groepper, Daniel; Tagen, Michael; Christensen, Robbin; Navid, Fariba; Gajjar, Amar; Stewart, Clinton F.

    2010-01-01

    Background Cyclophosphamide, an alkylating agent, is widely used for the treatment of many adult and pediatric malignancies. The stability of cyclophosphamide in aqueous- and methylcellulose-based oral suspending vehicles is currently unknown. Objectives The goals of this study were (1) to develop and validate a stability-indicating HPLC method to measure cyclophosphamide concentrations in simple syrup and Ora-Plus, and (2) to assess the 56-day chemical stability and physical appearance of cyclophosphamide in these suspensions at both room temperature and 4°C. Methods The i.v. formulation of cyclophosphamide was diluted to 20 mg/mL in normal saline, compounded 1:1 with either suspending vehicle, and stored in the dark in 3mL amber polypropylene oral syringes at 4°C and 22°C. Aliquots from each syringe were obtained on days 0, 3, 7, 14, 21, 28, 35, 42, 49, and 56 and assayed using the validated stability-indicating HPLC-UV method. A C18 analytical column was used to separate cyclophosphamide from the internal standard, ifosfamide, with a mobile phase of 21% acetonitrile in 79% sodium phosphate buffer. The suspension was examined for odor change, visually examined under normal fluorescent light for color change, and examined under a light microscope for evidence of microbial growth. Results Samples of cyclophosphamide in both simple syrup and Ora-Plus were stable when kept at 4°C for at least 56 days. At room temperature, cyclophosphamide in simple syrup and Ora-Plus had a shelf life of 8 and 3 days, respectively. No changes in color or odor or evidence of microbial growth were observed. Conclusion Cyclophosphamide can be extemporaneously prepared in simple syrup or Ora-Plus and stored at least 2 months under refrigeration without significant degradation. PMID:20103616

  2. Stability of cyclophosphamide in extemporaneous oral suspensions.

    PubMed

    Kennedy, Rachel; Groepper, Daniel; Tagen, Michael; Christensen, Robbin; Navid, Fariba; Gajjar, Amar; Stewart, Clinton F

    2010-02-01

    Cyclophosphamide, an alkylating agent, is widely used for the treatment of many adult and pediatric malignancies. The stability of cyclophosphamide in aqueous- and methylcellulose-based oral suspending vehicles is currently unknown. To develop and validate a stability-indicating high-performance liquid chromatography (HPLC) method to measure cyclophosphamide concentrations in simple syrup and Ora-Plus, and assess the 56-day chemical stability and physical appearance of cyclophosphamide in these suspensions at both room temperature (22 degrees C) and 4 degrees C. The intravenous formulation of cyclophosphamide was diluted to 20 mg/mL in NaCl 0.9%, compounded 1:1 with either suspending vehicle, and stored in the dark in 3-mL amber polypropylene oral syringes at 4 degrees C and 22 degrees C. Aliquots from each syringe were obtained on days 0, 3, 7, 14, 21, 28, 35, 42, 49, and 56 and assayed using the validated stability-indicating HPLC-UV method. A C18 analytical column was used to separate cyclophosphamide from the internal standard, ifosfamide, with a mobile phase of 21% acetonitrile in 79% sodium phosphate buffer. The suspension was examined for odor change, visually examined under normal fluorescent light for color change, and examined under a light microscope for evidence of microbial growth. Samples of cyclophosphamide in both simple syrup and Ora-Plus were stable when kept at 4 degrees C for at least 56 days. At room temperature, cyclophosphamide in simple syrup and Ora-Plus had a shelf life of 8 and 3 days, respectively. No changes in color or odor or evidence of microbial growth were observed. Cyclophosphamide can be extemporaneously prepared in simple syrup or Ora-Plus and stored for at least 2 months under refrigeration without significant degradation.

  3. Development of validated stability indicating assay method for simultaneous estimation of metformin hydrochloride and vildagliptin by RP-HPLC.

    PubMed

    Satheeshkumar, N; Pradeepkumar, M; Shanthikumar, S; Rao, V J

    2014-03-01

    A simple, precise and stability-indicating HPLC method was developed and validated for the simultaneous determination of metformin hydrochloride (MET) and vildagliptin (VLG) in pharmaceutical dosage forms. The method involves use of easily available inexpensive laboratory reagents. The separation was achieved on Grace Cyano column (250 mm×4.6 mm) 5 µm with isocratic flow. The mobile phase was pumped at a flow rate of 1.0 mL/min, consisted of 25 mM ammonium bicarbonate buffer and acetonitrile (65:35, v/v). The UV detection was carried out at 207 nm. A linear response was observed over the concentration range of 25-125 µg/mL for MET and 50-250 µg/mL for VLG respectively. Limit of detection and limit of quantification for MET were 0.36 µg/mL and 1.22 µg/mL, and for VLG were 0.75 µg/mL and 2.51 µg/mL respectively. The method was successfully validated in accordance to ICH guidelines acceptance criteria for specificity, linearity, accuracy, precision, robustness, and system suitability. Individual drugs (MET and VLG) were exposed to thermal, photolytic, hydrolytic and oxidative stress conditions. The resultant stressed samples were analyzed by the proposed method. The method gave high resolution among the degradation products and the analytes. The peak purity of analyte peak in the stressed samples was confirmed by photo diode array detector. The proposed method was successfully applied for the quantitative analysis of MET and VLG in tablet dosage form, which will help to improve quality control and contribute to stability studies of pharmaceutical tablets containing these drugs. © Georg Thieme Verlag KG Stuttgart · New York.

  4. Validation and application of a stability-indicating HPLC method for the in vitro determination of gastric and intestinal stability of venlafaxine.

    PubMed

    Asafu-Adjaye, Ebenezer B; Faustino, Patrick J; Tawakkul, Mobin A; Anderson, Lawrence W; Yu, Lawrence X; Kwon, Hyojong; Volpe, Donna A

    2007-04-11

    Gastrointestinal stability of venlafaxine was evaluated in vitro in simulated gastric (SGF) and intestinal (SIF) fluids using a stability indicating HPLC method. The method was validated using a 5 microm Ascentis C18 column (150 mm x 4.6 mm) and mobile phase consisting of 30% acetonitrile in 20 mM potassium phosphate buffer (pH 6.5) delivered isocratically at a flow rate of 1 mL/min with UV detection at 228 nm. Venlafaxine in USP simulated gastric and intestinal fluids (0.4 mg/mL) was incubated at 37 degrees C in a shaking water bath. The gastric stability study samples were assayed at 0, 15, 30 and 60 min intervals while sampling for the intestinal stability study was at 0, 1, 2 and 3 h. System suitability determinations gave R.S.D.s of 0.68, 0.5 and 3.9% for retention factor (k'), peak area and tailing factor, respectively. The method was shown to be accurate, precise, specific, and linear over the analytical range. Intra- and inter-day precision was <5.3%. Forced degradation studies of drug substance in basic media at 70 degrees C as well as in H2O2 for 1 h and ultra-violet photostability studies at 255 and 365 nm for 24 h did not produce any detectable degradation products. Forced degradation studies of drug substance in acidic media at 70 degrees C for 1 h produced the dehydro-venlafaxine degradant. Venlafaxine was stable in SGF (pH approximately 1.2) for the 1-h incubation period and in SIF (pH 6.8) up to 3 h with <1.5% relative difference (RD) between the amount of drug added and that found for all time points. This stability experiment in simulated gastric and intestinal fluids suggests that drug loss in the gastrointestinal tract takes place by membrane permeation rather than a degradation process.

  5. A Stability Indicating HPLC Method for the Determination of Fluvoxamine in Pharmaceutical Dosage Forms.

    PubMed

    Souri, Effat; Donyayi, Hassan; Khaniha, Reza Ahmad; Barazandeh Tehrani, Maliheh

    2015-01-01

    Fluvoxamine maleate is a selective serotonin reuptake inhibitor, which is used for the treatment of different types of depressive disorders. In the present study, a stability indicating HPLC method was developed and validated for the determination of fluvoxamine maleate. The chromatographic separation was carried out using a Nova-Pak CN column and a mixture of K2HPO4 50 mM (pH 7.0) and acetonitrile (60: 40, v/v) as the mobile phase. Target compounds were detected using a UV detector set at 235 nm. The developed method was linear over the concentration range of 1-80 μg/ml with acceptable precision (CV values < 2.0%) and accuracy (error values < 1.6%). The degradation studies showed that fluvoxamine maleate is relatively unstable under acidic, basic and oxidative conditions and also when exposed to UV radiation. On the other hand, the bulk powder of fluvoxamine maleate was relatively stable when exposed to visible light or heat. The proposed method was successfully applied for the determination of active ingredient of fluvoxamine dosage form without any interference from tablet excipients.

  6. A Stability-Indicating HPLC-DAD Method for Determination of Stiripentol: Development, Validation, Kinetics, Structure Elucidation and Application to Commercial Dosage Form

    PubMed Central

    Darwish, Hany W.; Abdelhameed, Ali S.; Bakheit, Ahmed H.; Khalil, Nasr Y.; Al-Majed, Abdulrahman A.

    2014-01-01

    A rapid, simple, sensitive, and accurate isocratic reversed-phase stability-indicating high performance liquid chromatography method has been developed and validated for the determination of stiripentol and its degradation product in its bulk form and pharmaceutical dosage form. Chromatographic separation was achieved on a Symmetry C18 column and quantification was achieved using photodiode array detector (DAD). The method was validated in accordance with the ICH requirements showing specificity, linearity (r 2 = 0.9996, range of 1–25 μg/mL), precision (relative standard deviation lower than 2%), accuracy (mean recovery 100.08 ± 1.73), limits of detection and quantitation (LOD = 0.024 and LOQ = 0.081 μg/mL), and robustness. Stiripentol was subjected to various stress conditions and it has shown marked stability under alkaline hydrolytic stress conditions, thermal, oxidative, and photolytic conditions. Stiripentol degraded only under acidic conditions, forming a single degradation product which was well resolved from the pure drug with significantly different retention time values. This degradation product was characterized by 1H-NMR and 13C-NMR spectroscopy as well as ion trap mass spectrometry. The results demonstrated that the method would have a great value when applied in quality control and stability studies for stiripentol. PMID:25371844

  7. Identification of new impurities of enalapril maleate on oxidation in the presence of magnesium monoperoxyphthalate.

    PubMed

    Toporisic, Rebeka; Mlakar, Anita; Hvala, Jernej; Prislan, Iztok; Zupancic-Kralj, Lucija

    2010-06-05

    Stress stability testing and forced degradation were used to determine the stability of enalapril maleate (EM) and to find a degradation pathway for the drug. The degradation impurities, formed under different stressed conditions, were investigated by HPLC and UPLC-MS methods. HPLC analysis showed several degradation impurities of which several were already determined, but on oxidation in the presence of magnesium monoperoxyphthalate (MMPP) several impurities of EM were observed which were not yet characterized. The HPLC methods for determination of EM were validated. The linearity of HPLC method was established in the concentration range between 0.5 and 10 microg/mL with correlation coefficient greater than 0.99. The LOD of EM was 0.2 microg/mL and LOQ was 0.5 microg/mL. The validated HPLC method was used to determine the degradation impurities in samples after stress stability testing and forced degradation of EM. In order to identify new degradation impurities of EM after forced degradation UPLC-MS/MS(n), Orbitrap has been used. It was found that new impurities are oxidation products: (S)-1-((S)-2-((S)-1-ethoxy-4-(o,m,p-hydroxyphenyl)-1-oxobutan-2-ylamino)propanoyl)pyrrolidine-2-carboxylic acid, (2S)-1-((2S)-2-((2S)-1-ethoxy-4-hydroxy-1-oxo-4-phenylbutan-2-ylamino)propanoyl)pyrrolidine-2-carboxylic acid. (S)-2-(3-phenylpropylamino)-1-(pyrrolidin-1-yl)propan-1-one was identified as a new degradation impurity. Copyright (c) 2010. Published by Elsevier B.V.

  8. Stability-indicating HPLC Method for Simultaneous Determination of Terbutaline Sulphate, Bromhexine Hydrochloride and Guaifenesin

    PubMed Central

    Porel, A.; Haty, Sanjukta; Kundu, A.

    2011-01-01

    The aim of the present study was the development and subsequent validation of a simple, precise and stability-indicating reversed phase HPLC method for the simultaneous determination of guaifenesin, terbutaline sulphate and bromhexine hydrochloride in the presence of their potential impurities in a single run. The photolytic as well as hydrolytic impurities were detected as 3,5-dihydroxybenzoic acid, 3,5-dihydroxybenzaldehyde, 1-(3,5-dihydroxyphenyl)-2-[(1,1-dimethylethyl) amino]-ethanone from terbutaline, 2-methoxyphenol and an unknown impurity identified as (2RS)-3-(2-hydroxyphenoxy)-propane-1,2-diol from guaifenesin. The chromatographic separation of all the three active components and their impurities was achieved on Wakosil II column, using phosphate buffer (pH 3.0) and acetonitrile as mobile phase which was delivered initially in the ratio of 80:20 (v/v) for 18 min, then changed to 60:40 (v/v) for next 12 min, and finally equilibrated back to 80:20 (v/v) for 10 min. Other HPLC parameters were: Flow rate at 1.0 ml/min, detection wavelengths 248 and 280 nm, injection volume 10 μl. The calibration graphs plotted with five concentrations of each component were linear with a regression coefficient R2 >0.9999. The limit of detection and limit of quantitation were estimated for all the five impurities. The established method was then validated for linearity, precision, accuracy, and specificity and demonstrated to be applicable to the determination of the active ingredients in commercial and model cough syrup. No interference from the formulation excipients was observed. These results suggest that this LC method can be used for the determination of multiple active ingredients and their impurities in a cough and cold syrup. PMID:22131621

  9. Stability-indicating HPLC Method for Simultaneous Determination of Terbutaline Sulphate, Bromhexine Hydrochloride and Guaifenesin.

    PubMed

    Porel, A; Haty, Sanjukta; Kundu, A

    2011-01-01

    The aim of the present study was the development and subsequent validation of a simple, precise and stability-indicating reversed phase HPLC method for the simultaneous determination of guaifenesin, terbutaline sulphate and bromhexine hydrochloride in the presence of their potential impurities in a single run. The photolytic as well as hydrolytic impurities were detected as 3,5-dihydroxybenzoic acid, 3,5-dihydroxybenzaldehyde, 1-(3,5-dihydroxyphenyl)-2-[(1,1-dimethylethyl) amino]-ethanone from terbutaline, 2-methoxyphenol and an unknown impurity identified as (2RS)-3-(2-hydroxyphenoxy)-propane-1,2-diol from guaifenesin. The chromatographic separation of all the three active components and their impurities was achieved on Wakosil II column, using phosphate buffer (pH 3.0) and acetonitrile as mobile phase which was delivered initially in the ratio of 80:20 (v/v) for 18 min, then changed to 60:40 (v/v) for next 12 min, and finally equilibrated back to 80:20 (v/v) for 10 min. Other HPLC parameters were: Flow rate at 1.0 ml/min, detection wavelengths 248 and 280 nm, injection volume 10 μl. The calibration graphs plotted with five concentrations of each component were linear with a regression coefficient R(2) >0.9999. The limit of detection and limit of quantitation were estimated for all the five impurities. The established method was then validated for linearity, precision, accuracy, and specificity and demonstrated to be applicable to the determination of the active ingredients in commercial and model cough syrup. No interference from the formulation excipients was observed. These results suggest that this LC method can be used for the determination of multiple active ingredients and their impurities in a cough and cold syrup.

  10. Dual Wavelength RP-HPLC Method for Simultaneous Determination of Two Antispasmodic Drugs: An Application in Pharmaceutical and Human Serum.

    PubMed

    Hasan, Najmul; Chaiharn, Mathurot; Khan, Sauleha; Khalid, Hira; Sher, Nawab; Siddiqui, Farhan Ahmed; Siddiqui, Muhammad Zain

    2013-01-01

    A reverse phase stability indicating HPLC method for simultaneous determination of two antispasmodic drugs in pharmaceutical parenteral dosage forms (injectable) and in serum has been developed and validated. Mobile phase ingredients consist of Acetonitrile : buffer : sulfuric acid 0.1 M (50 : 50 : 0.3 v/v/v), at flow rate 1.0 mL/min using a Hibar μ Bondapak ODS C18 column monitored at dual wavelength of 266 nm and 205 nm for phloroglucinol and trimethylphloroglucinol, respectively. The drugs were subjected to stress conditions of hydrolysis (oxidation, base, acid, and thermal degradation). Oxidation degraded the molecule drastically while there was not so much significant effect of other stress conditions. The calibration curve was linear with a correlation coefficient of 0.9999 and 0.9992 for PG and TMP, respectively. The drug recoveries fall in the range of 98.56% and 101.24% with 10 pg/mL and 33 pg/mL limit of detection and limit of quantification for both phloroglucinol and trimethylphloroglucinol. The method was validated in accordance with ICH guidelines and was applied successfully to quantify the amount of trimethylphloroglucinol and phloroglucinol in bulk, injectable form and physiological fluid. Forced degradation studies proved the stability indicating abilities of the method.

  11. A Simple and Specific Stability- Indicating RP-HPLC Method for Routine Assay of Adefovir Dipivoxil in Bulk and Tablet Dosage Form.

    PubMed

    Darsazan, Bahar; Shafaati, Alireza; Mortazavi, Seyed Alireza; Zarghi, Afshin

    2017-01-01

    A simple and reliable stability-indicating RP-HPLC method was developed and validated for analysis of adefovir dipivoxil (ADV).The chromatographic separation was performed on a C 18 column using a mixture of acetonitrile-citrate buffer (10 mM at pH 5.2) 36:64 (%v/v) as mobile phase, at a flow rate of 1.5 mL/min. Detection was carried out at 260 nm and a sharp peak was obtained for ADV at a retention time of 5.8 ± 0.01 min. No interferences were observed from its stress degradation products. The method was validated according to the international guidelines. Linear regression analysis of data for the calibration plot showed a linear relationship between peak area and concentration over the range of 0.5-16 μg/mL; the regression coefficient was 0.9999and the linear regression equation was y = 24844x-2941.3. The detection (LOD) and quantification (LOQ) limits were 0.12 and 0.35 μg/mL, respectively. The results proved the method was fast (analysis time less than 7 min), precise, reproducible, and accurate for analysis of ADV over a wide range of concentration. The proposed specific method was used for routine quantification of ADV in pharmaceutical bulk and a tablet dosage form.

  12. Influence of sodium metabisulfite and glutathione on the stability of vitamin C in O/W emulsion and extemporaneous aqueous gel.

    PubMed

    Maia, Adriana M; Baby, André Rolim; Pinto, Claudinéia A S O; Yasaka, Wilson J; Suenaga, Eunice; Kaneko, Telma M; Velasco, Maria Valéria Robles

    2006-09-28

    Vitamin C exerts several functions on skin as collagen synthesis, depigmentant and antioxidant activity. Vitamin C is unstable in the presence of oxygen, luminosity, humidity, high temperatures and heavy metals, which presents a significant challenge to the development of cosmetic formulations. Therefore, the utilization of an effective antioxidant system is required to maintain the vitamin C stability. The purpose of this research work was to develop prototypes of cosmetic formulations, as O/W emulsion and extemporaneous aqueous gel, containing vitamin C and to evaluate the influence of sodium metabisulfite (SMB) and glutathione (GLT), as antioxidants, on the stability of the active substance. A HPLC stability-indicating method was developed and validated for this study and stability assays were performed in 90 and 26 days and storage conditions were 5.0+/-0.5, 24+/-2 and 40.0+/-0.5 degrees C. The HPLC stability-indicating method showed linearity (r(2)>0.99), specificity, R.S.D.<1.22% and accuracy/recovery ranging from 95.46 to 101.54%. Preparations with SMB or GLT and the antioxidant-free presented results statistically distinct, demonstrating the necessity of the antioxidant system addition. O/W emulsions with SMB or GLT retained the vitamin C content >90.38% stored at 5.0+/-0.5 and 24+/-2 degrees C. For the aqueous gel with SMB or GLT, the active substance concentration was maintained >94.03%. Considering the vitamin C stability, the SMB and the GLT showed to be statistically adequate, as antioxidants, for the cosmetic formulations.

  13. Quantitative and pattern recognition analyses of magnoflorine, spinosin, 6'''-feruloyl spinosin and jujuboside A by HPLC in Zizyphi Semen.

    PubMed

    Kim, Won Il; Zhao, Bing Tian; Zhang, Hai Yan; Lee, Je Hyun; Son, Jong Keun; Woo, Mi Hee

    2014-01-01

    Two rapid and simple HPLC methods with UV detector to determine three main compounds (magnoflorine, spinosin and 6'''-feruloyl spinosin) and evaporative light scattering detector (ELSD) to determine jujuboside A were developed for the chemical analyses of Zizyphi Semen. Magnoflorine, spinosin, and 6'''-feruloyl spinosin were separated with an YMC J'sphere ODS-H80 column (250 mm × 4.6 mm, 4 μm) by the gradient elution followed by the isocratic elution using methanol with 0.1 % formic acid and water with 0.1 % formic acid as the mobile phase. The flow rate was 1.0 mL/min. Jujuboside A was separated by HPLC-ELSD with YoungJinBioChrom Aegispak C18-L column (250 mm × 4.6 mm, 5 μm) column in a gradient elution using methanol with 0.1 % formic acid (A) and water with 0.1 % formic acid as the mobile phase. These two methods were fully validated with respect to linearity, precision, accuracy, stability, and robustness. These HPLC methods were applied successfully to quantify four compounds in a Zizyphi Semen extract. The HPLC analytical methods were validated for pattern recognition analysis by repeated analysis of 91 seed samples corresponding to 48 Zizyphus jujuba var. spinosa (J01-J48) and 43 Zizyphus mauritiana (M01-M43). The results indicate that these methods are suitable for a quality evaluation of Zizyphi Semen.

  14. Validation of an HPLC method for the quantification of ambroxol hydrochloride and benzoic acid in a syrup as pharmaceutical form stress test for stability evaluation.

    PubMed

    Heinänen, M; Barbas, C

    2001-03-01

    A method is described for ambroxol, trans-4-(2-amino-3,5-dibromobenzylamino) cyclohexanol hydrochloride, and benzoic acid separation by HPLC with UV detection at 247 nm in a syrup as pharmaceutical presentation. Optimal conditions were: Column Symmetry Shield RPC8, 5 microm 250 x 4.6 mm, and methanol/(H(3)PO(4) 8.5 mM/triethylamine pH=2.8) 40:60 v/v. Validation was performed using standards and the pharmaceutical preparation which contains the compounds described above. Results from both standards and samples show suitable validation parameters. The pharmaceutical grade substances were tested by factors that could influence the chemical stability. These reaction mixtures were analysed to evaluate the capability of the method to separate degradation products. Degradation products did not interfere with the determination of the substances tested by the assay.

  15. A New Improved RP-HPLC Method for Assay of Rosuvastatin Calcium in Tablets

    PubMed Central

    Kaila, H. O.; Ambasana, M. A.; Thakkar, R. S.; Saravaia, H. T.; Shah, A. K.

    2010-01-01

    A reliable and sensitive isocratic stability indicating RP-HPLC method has been developed and validated for assay of rosuvastatin calcium in tablets and for determination of content uniformity. An isocratic separation of rosuvastatin calcium was achieved on YMC C8, 150×4.6 mm i.d., 5 μm particle size columns with a flow rate of 1.5 ml/min and using a photodiode array detector to monitor the eluate at 242 nm. The mobile phase consisted of acetonitrile: water (40:60, v/v) pH 3.5 adjusted with phosphoric acid. The drug was subjected to oxidation, hydrolysis, photolysis and thermal degradation. All degradation products in an overall analytical run time of approximately 10 min with the parent compound rosuvastatin eluting at approximately 5.2 min. Response was a linear function of drug concentration in the range of 0.5-80 μg/ml (r2= 0.9993) with a limit of detection and quantification of 0.1 and 0.5 μg/ml respectively. Accuracy (recovery) was between 99.6 and 101.7%. Degradation products resulting from the stress studies did not interfere with the detection of rosuvastatin and the assay is thus stability-indicating. PMID:21694991

  16. Nifedipine-loaded polymeric nanocapsules: validation of a stability-indicating HPLC method to evaluate the drug entrapment efficiency and in vitro release profiles.

    PubMed

    Granada, Andréa; Tagliari, Monika Piazzon; Soldi, Valdir; Silva, Marcos António Segatto; Zanetti-Ramos, Betina Ghiel; Fernandes, Daniel; Stulzer, Hellen Karine

    2013-01-01

    A simple stability-indicating analytical method was developed and validated to quantify nifedipine in polymeric nanocapsule suspensions; an in vitro drug release study was then carried out. The analysis was performed using an RP C18 column, UV-Vis detection at 262 nm, and methanol-water (70 + 30, v/v) mobile phase at a flow rate of 1.2 mL/min. The method was validated in terms of specificity, linearity and range, LOQ, accuracy, precision, and robustness. The results obtained were within the acceptable ranges. The nanocapsules, made of poly(epsilon-caprolactone), were prepared by the solvent displacement technique and showed high entrapment efficiency. The entrapment efficiency was 97.6 and 98.2% for the nifedipine-loaded polymeric nanocapsules prepared from polyvinyl alcohol (PVA) and Pluronic F68 (PF68), respectively. The particle size and zeta potential of nanocapsules were found to be influenced by the nature of the stabilizer used. The mean diameter and zeta potential for nanocapsules with PVA and PF68 were 290.9 and 179.9 nm, and -17.7 mV and -32.7 mV, respectively. The two formulations prepared showed a drug release of up to 70% over 4 days. This behavior indicates the viability of this drug delivery system for use as a controlled-release system.

  17. Development of Modern Methods for Determination of Stabilizers in Propellants

    DTIC Science & Technology

    1996-04-01

    powder will! . gtve information Jbout the history of this powder and an indication of its future: usefulness. In othdrs words, the determination of...been excluded in Tables I and II. According to Table I, in order to develop an HPLC method for DPA-stabilized powders , the products that should be... powders were determined by each country using its own HPLC method . The results are given in Table XVI. As indicated, the agreement between the two

  18. Identification and characterization of stress degradants of lacosamide by LC-MS and ESI-Q-TOF-MS/MS: development and validation of a stability indicating RP-HPLC method.

    PubMed

    Ramisetti, Nageswara Rao; Kuntamukkala, Ramakrishna; Lakshetti, Sridhar; Sripadi, Prabhakar

    2014-07-01

    The current study dealt with the degradation behavior of lacosamide (LAC) under ICH prescribed stress conditions. LAC was found to be labile under acid and base hydrolytic stress conditions, while it was stable to neutral hydrolytic, oxidative, photolytic and thermal stress. In total, seven degradation products (DPs) were formed, which were separated on a C18 column using a stability-indicating method. LC-MS analyses indicated that one of the DPs had the same molecular mass as that of the drug. Structural characterization of DPs was carried out using ESI-Q-TOF-MS/MS technique. The degradation pathways and mechanisms of degradation of the drug were delineated by carrying out the degradation in different co-solvents viz. methanol, deuterated methanol, ethanol, 1-propanol and acetonitrile. The developed LC method was validated for the determination of related substances and assay of LAC as per ICH guidelines. This study demonstrates a comprehensive approach of LAC degradation studies during its development phase. Copyright © 2014. Published by Elsevier B.V.

  19. A bioanalytical HPLC method for coumestrol quantification in skin permeation tests followed by UPLC-QTOF/HDMS stability-indicating method for identification of degradation products.

    PubMed

    Bianchi, Sara E; Teixeira, Helder F; Kaiser, Samuel; Ortega, George G; Schneider, Paulo Henrique; Bassani, Valquiria L

    2016-05-01

    Coumestrol is present in several species of the Fabaceae family widely distributed in plants. The estrogenic and antioxidant activities of this molecule show its potential as skin anti-aging agent. These characteristics reveal the interest in developing analytical methodology for permeation studies, as well as to know the stability of coumestrol identifying the major degradation products. Thus, the present study was designed, first, to develop and validate a versatile liquid chromatography (HPLC) method to quantify coumestrol in a hydrogel formulation in different porcine skin layers (stratum corneum, epidermis, and dermis) in permeation tests. In the stability-indicating test coumestrol samples were exposed to stress conditions: temperature, UVC light, oxidative, acid and alkaline media. The degradation products, as well as the constituents extracted from the hydrogel, adhesive tape or skin were not eluted in the retention time of the coumestrol. Hence, the HPLC method showed to be versatile, specific, accurate, precise and robust showing excellent performance for quantifying coumestrol in complex matrices involving skin permeation studies. Coumestrol recovery from porcine ear skin was found to be in the range of 97.07-107.28 μg/mL; the intra-day precision (repeatability) and intermediate precision (inter-day precision), respectively lower than 4.71% and 2.09%. The analysis using ultra-performance liquid chromatography coupled to a quadrupole time-of-flight high definition mass spectrometry detector (UPLC-QTOF/HDMS) suggest the MS fragmentation patterns and the chemical structure of the main degradation products. These results represent new and relevant findings for the development of coumestrol pharmaceutical and cosmetic products. Copyright © 2016 Elsevier B.V. All rights reserved.

  20. Stability of alemtuzumab solutions at room temperature.

    PubMed

    Goldspiel, Justin T; Goldspiel, Barry R; Grimes, George J; Yuan, Peng; Potti, Gopal

    2013-03-01

    The 24-hour stability of alemtuzumab solutions prepared at concentrations not included in the product label and stored in glass or polyolefin containers at room temperature was evaluated. Triplicate solutions of alemtuzumab (6.67, 40, and 120 μg/mL) in 0.9% sodium chloride were prepared in either glass bottles or polyolefin containers and stored at room temperature under normal fluorescent lighting conditions. The solutions were analyzed by a validated stability-indicating high-performance liquid chromatography (HPLC) assay at time zero and 8, 14, and 24 hours after preparation; solution pH values were measured and the containers visually inspected at all time points. Stability was defined as the retention of ≥90% of the initial alemtuzumab concentration. HPLC analysis indicated that the percentage of the initial alemtuzumab concentration retained was >90% for all solutions evaluated, with no significant changes over the study period. The most dilute alemtuzumab solution (6.67 μg/mL) showed some degradation (91% of the initial concentration retained at hour 24), whereas the retained concentration was >99% for all other preparations throughout the study period. Solution pH values varied by drug concentration but did not change significantly over 24 hours. No evidence of particle formation was detected in any solution by visual inspection at any time during the study. Solutions of alemtuzumab 6.67 μg/mL stored in glass bottles and solutions of 40 and 120 μg/mL stored in polyolefin containers were stable for at least 24 hours at room temperature.

  1. A validated stability-indicating HPLC method for determination of varenicline in its bulk and tablets

    PubMed Central

    2011-01-01

    A simple, sensitive and accurate stability-indicating HPLC method has been developed and validated for determination of varenicline (VRC) in its bulk form and pharmaceutical tablets. Chromatographic separation was achieved on a Zorbax Eclipse XDB-C8 column (150 mm × 4.6 mm i.d., particle size 5 μm, maintained at ambient temperature) by a mobile phase consisted of acetonitrile and 50 mM potassium dihydrogen phosphate buffer (10:90, v/v) with apparent pH of 3.5 ± 0.1 and a flow rate of 1.0 ml/min. The detection wavelength was set at 235 nm. VRC was subjected to different accelerated stress conditions. The degradation products, when any, were well resolved from the pure drug with significantly different retention time values. The method was linear (r = 0.9998) at a concentration range of 2 - 14 μg/ml. The limit of detection and limit of quantitation were 0.38 and 1.11 μg/ml, respectively. The intra- and inter-assay precisions were satisfactory; the relative standard deviations did not exceed 2%. The accuracy of the method was proved; the mean recovery of VRC was 100.10 ± 1.08%. The proposed method has high throughput as the analysis involved short run-time (~ 6 min). The method met the ICH/FDA regulatory requirements. The proposed method was successfully applied for the determination of VRC in bulk and tablets with acceptable accuracy and precisions; the label claim percentages were 99.65 ± 0.32%. The results demonstrated that the method would have a great value when applied in quality control and stability studies for VRC. PMID:21672253

  2. A Study of Method Development, Validation, and Forced Degradation for Simultaneous Quantification of Paracetamol and Ibuprofen in Pharmaceutical Dosage Form by RP-HPLC Method

    PubMed Central

    Jahan, Md. Sarowar; Islam, Md. Jahirul; Begum, Rehana; Kayesh, Ruhul; Rahman, Asma

    2014-01-01

    A rapid and stability-indicating reversed phase high-performance liquid chromatography (RP-HPLC) method was developed for simultaneous quantification of paracetamol and ibuprofen in their combined dosage form especially to get some more advantages over other methods already developed for this combination. The method was validated according to United States Pharmacopeia (USP) guideline with respect to accuracy, precision, specificity, linearity, solution stability, robustness, sensitivity, and system suitability. Forced degradation study was validated according to International Conference on Harmonisation (ICH). For this, an isocratic condition of mobile phase comprising phosphate buffer (pH 6.8) and acetonitrile in a ratio of 65:35, v/v at a flow rate of 0.7 mL/minute over RP C18 (octadecylsilane (ODS), 150 × 4.6 mm, 5 μm, Phenomenex Inc.) column at ambient temperature was maintained. The method showed excellent linear response with correlation coefficient (R2) values of 0.999 and 1.0 for paracetamol and ibuprofen respectively, which were within the limit of correlation coefficient (R2 > 0.995). The percent recoveries for two drugs were found within the acceptance limit of (97.0–103.0%). Intra-and inter-day precision studies of the new method were less than the maximum allowable limit percentage of relative standard deviation (%RSD) ≤ 2.0. Forced degradation of the drug product was carried out as per the ICH guidelines with a view to establishing the stability-indicating property of this method and providing useful information about the degradation pathways, degradation products, and how the quality of a drug substance and drug product changes with time under the influence of various stressing conditions. The degradation of ibuprofen was within the limit (5–20%, according to the guideline of ICH), while paracetamol showed <20% degradation in oxidation and basic condition. PMID:25452691

  3. A Study of Method Development, Validation, and Forced Degradation for Simultaneous Quantification of Paracetamol and Ibuprofen in Pharmaceutical Dosage Form by RP-HPLC Method.

    PubMed

    Jahan, Md Sarowar; Islam, Md Jahirul; Begum, Rehana; Kayesh, Ruhul; Rahman, Asma

    2014-01-01

    A rapid and stability-indicating reversed phase high-performance liquid chromatography (RP-HPLC) method was developed for simultaneous quantification of paracetamol and ibuprofen in their combined dosage form especially to get some more advantages over other methods already developed for this combination. The method was validated according to United States Pharmacopeia (USP) guideline with respect to accuracy, precision, specificity, linearity, solution stability, robustness, sensitivity, and system suitability. Forced degradation study was validated according to International Conference on Harmonisation (ICH). For this, an isocratic condition of mobile phase comprising phosphate buffer (pH 6.8) and acetonitrile in a ratio of 65:35, v/v at a flow rate of 0.7 mL/minute over RP C18 (octadecylsilane (ODS), 150 × 4.6 mm, 5 μm, Phenomenex Inc.) column at ambient temperature was maintained. The method showed excellent linear response with correlation coefficient (R (2)) values of 0.999 and 1.0 for paracetamol and ibuprofen respectively, which were within the limit of correlation coefficient (R (2) > 0.995). The percent recoveries for two drugs were found within the acceptance limit of (97.0-103.0%). Intra-and inter-day precision studies of the new method were less than the maximum allowable limit percentage of relative standard deviation (%RSD) ≤ 2.0. Forced degradation of the drug product was carried out as per the ICH guidelines with a view to establishing the stability-indicating property of this method and providing useful information about the degradation pathways, degradation products, and how the quality of a drug substance and drug product changes with time under the influence of various stressing conditions. The degradation of ibuprofen was within the limit (5-20%, according to the guideline of ICH), while paracetamol showed <20% degradation in oxidation and basic condition.

  4. ESI-MSn and LC-ESI-MS studies to characterize forced degradation products of bosentan and a validated stability-indicating LC-UV method.

    PubMed

    Bansal, Gulshan; Singh, Ranjit; Saini, Balraj; Bansal, Yogita

    2013-01-01

    The present study reports the characterization of forced degradation products of bosentan and a validated stability-indicating HPLC method for the stability testing of bosentan tablets. The forced degradation was carried out under the conditions of hydrolysis, oxidation, dry heat and photolysis. The drug was found unstable in acid, alkali and oxidative media whereas stable to the hydrolysis in water, to dry heat and to photolysis. In total, six degradation products were formed in all conditions which were resolved in a single run on a C-18 column with gradient elution using ammonium acetate buffer (pH 4.5, 5.0mM), methanol and acetonitrile. Structures of all the degradation products were characterized through +ESI-MS(n) and LC-ESI-MS spectral data of bosentan as well as LC-ESI-MS spectral data of the products. The products II-VI were characterized as 6-amino-[2,2']bipyrimidinyl-4,5-diol, 6-amino-5-(2-methoxyphenoxy)-[2,2']-bipyrimidinyl-4-ol, 2-[6-amino-5-(2-methoxyphenoxy)-[2,2']-bipyrimidinyl-4-yloxy]-ethanol, 4-tert-butyl-N-[6-(1-methoxyethoxy)-5-(2-methoxyphenoxy)-[2,2']-bipyrimidinyl-4-yl]-benzenesulfonamide and 4-tert-butyl-N-[6-hydroxy-5-(2-methoxyphenoxy)-[2,2']bipyrimidinyl-4-yl]-benzenesulfonamide, respectively. The peak of the product I was found to be due to two secondary degradation products which co-eluted and were characterized as β-hydroxyethyl p-tert-butylphenylsulfonate (Ia) and 2-[2-(2-hydroxyethoxy)-phenoxy]-ethanol (Ib). These products were formed due to hydrolysis of sulfonamide and alkylaryl ether and the diaryl ether linkages as well as dehydration of the primary alcohol group. The most probable degradation mechanisms were proposed. The HPLC method was found to be stability-indicating, linear (2-100 μg ml(-1)), accurate, precise, sensitive, specific, rugged and robust for quantitation of the drug. The method was applied to the stability testing of the commercially available bosentan tablets successfully. Copyright © 2012 Elsevier B.V. All rights reserved.

  5. A validated stability-indicating RP-HPLC method for levofloxacin in the presence of degradation products, its process related impurities and identification of oxidative degradant.

    PubMed

    Lalitha Devi, M; Chandrasekhar, K B

    2009-12-05

    The objective of current study was to develop a validated specific stability indicating reversed-phase liquid chromatographic method for the quantitative determination of levofloxacin as well as its related substances determination in bulk samples, pharmaceutical dosage forms in the presence of degradation products and its process related impurities. Forced degradation studies were performed on bulk sample of levofloxacin as per ICH prescribed stress conditions using acid, base, oxidative, water hydrolysis, thermal stress and photolytic degradation to show the stability indicating power of the method. Significant degradation was observed during oxidative stress and the degradation product formed was identified by LCMS/MS, slight degradation in acidic stress and no degradation was observed in other stress conditions. The chromatographic method was optimized using the samples generated from forced degradation studies and the impurity spiked solution. Good resolution between the peaks corresponds to process related impurities and degradation products from the analyte were achieved on ACE C18 column using the mobile phase consists a mixture of 0.5% (v/v) triethyl amine in sodium dihydrogen orthophosphate dihydrate (25 mM; pH 6.0) and methanol using a simple linear gradient. The detection was carried out at 294 nm. The limit of detection and the limit of quantitation for the levofloxacin and its process related impurities were established. The stressed test solutions were assayed against the qualified working standard of levofloxacin and the mass balance in each case was in between 99.4 and 99.8% indicating that the developed LC method was stability indicating. Validation of the developed LC method was carried out as per ICH requirements. The developed LC method was found to be suitable to check the quality of bulk samples of levofloxacin at the time of batch release and also during its stability studies (long term and accelerated stability).

  6. A validated specific stability-indicating RP-HPLC assay method for Ambrisentan and its related substances.

    PubMed

    Narayana, M B V; Chandrasekhar, K B; Rao, B M

    2014-09-01

    A validated specific stability-indicating reverse-phase liquid chromatographic method was developed for the quantitative determination of Ambrisentan as well as its related substances in bulk samples, pharmaceutical dosage forms in the presence of degradation products and its related impurities. Forced degradation studies were performed on bulk samples of Ambrisentan as per the ICH-prescribed stress conditions using acid, base, oxidative, thermal stress and photolytic degradation to show the stability-indicating power of the LC method. Significant degradation in acidic, basic stress conditions was observed and no degradation was observed in other stress conditions. The chromatographic method was optimized using the samples generated from the forced degradation studies and the impurity-spiked solution. Good resolution between the peaks corresponds to Ambrisentan-related impurities and degradation products from the analyte were achieved on a SunFire C18 column using a mobile phase consisting of a mixture of potassium dihydrogen orthophosphate at a pH adjusted to 2.5 with ortho-phosphoric acid in water and a mixture of acetonitrile:methanol using a simple linear gradient. The detection was carried out at 225 nm. The limit of detection and the limit of quantification for the Ambrisentan and its related impurities were established. The stressed test solutions were assayed against the qualified working standard of Ambrisentan and the mass balance in each case was between 98.9 and 100.3%, indicating that the developed LC method was stability indicating. Validation of the developed LC method was carried out as per the ICH requirements. The developed method was found to be suitable to check the quality of bulk samples of Ambrisentan at the time of batch release and also during its storage (long-term and accelerated stability). © The Author [2013]. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.

  7. Simultaneous quantification of five major active components in capsules of the traditional Chinese medicine ‘Shu-Jin-Zhi-Tong’ by high performance liquid chromatography

    PubMed Central

    Yang, Xing-Xin; Zhang, Xiao-Xia; Chang, Rui-Miao; Wang, Yan-Wei; Li, Xiao-Ni

    2011-01-01

    A simple and reliable high performance liquid chromatography (HPLC) method has been developed for the simultaneous quantification of five major bioactive components in ‘Shu-Jin-Zhi-Tong’ capsules (SJZTC), for the purposes of quality control of this commonly prescribed traditional Chinese medicine. Under the optimum conditions, excellent separation was achieved, and the assay was fully validated in terms of linearity, precision, repeatability, stability and accuracy. The validated method was applied successfully to the determination of the five compounds in SJZTC samples from different production batches. The HPLC method can be used as a valid analytical method to evaluate the intrinsic quality of SJZTC. PMID:29403711

  8. A validated stability indicating RP-HPLC method for estimation of Armodafinil in pharmaceutical dosage forms and characterization of its base hydrolytic product.

    PubMed

    Venkateswarlu, Kambham; Rangareddy, Ardhgeri; Narasimhaiah, Kanaka; Sharma, Hemraj; Bandi, Naga Mallikarjuna Raja

    2017-01-01

    The main objective of present study was to develop a RP-HPLC method for estimation of Armodafinil in pharmaceutical dosage forms and characterization of its base hydrolytic product. The method was developed for Armodafinil estimation and base hydrolytic products were characterized. The separation was carried out on C18 column by using mobile phase as mixture of water and methanol (45:55%v/v). Eluents were detected at 220nm at 1ml/min. Stress studies were performed with milder conditions followed by stronger conditions so as to get sufficient degradation around 20%. A total of five degradation products were detected and separated from analyte. The linearity of the proposed method was investigated in the range of 20-120µg/ml for Armodafinil. The detection limit and quantification limit was found to be 0.01183μg/ml and 0.035µg/ml respectively. The precision % RSD was found to be less than 2% and the recovery was between 98-102%. Armodafinil was found to be more sensitive to the base hydrolysis and yielded its carboxylic acid as degradant. The developed method was stability indicating assay, suitable to quantify Armodafinil in presence of possible degradants. The drug was sensitive to acid, base &photolytic stress and resistant to thermal &oxidation.

  9. Development of RP-HPLC, Stability Indicating Method for Degradation Products of Linagliptin in Presence of Metformin HCl by Applying 2 Level Factorial Design; and Identification of Impurity-VII, VIII and IX and Synthesis of Impurity-VII.

    PubMed

    Jadhav, Sushant B; Reddy, P Sunil; Narayanan, Kalyanaraman L; Bhosale, Popatrao N

    2017-06-27

    The novel reverse phase-high performance liquid chromatography (RP-HPLC), stability indicating method was developed for determination of linagliptin (LGP) and its related substances in linagliptin and metformin HCl (MET HCl) tablets by implementing design of experiment to understand the critical method parameters and their relation with critical method attributes; to ensure robustness of the method. The separation of nine specified impurities was achieved with a Zorbax SB-Aq 250 × 4.6 mm, 5 µm column, using gradient elution and a detector wavelength of 225 nm, and validated in accordance with International Conference on Harmonization (ICH) guidelines and found to be accurate, precise, reproducible, robust, and specific . The drug was found to be degrading extensively in heat, humidity, basic, and oxidation conditions and was forming degradation products during stability studies. After slight modification in the buffer and the column, the same method was used for liquid chromatography-mass spectrometry (LC-MS) and ultra-performance liquid chromatography -time-of-flight/mass spectrometry UPLC-TOF/MS analysis, to identify m/z and fragmentation of maximum unspecified degradation products i.e., Impurity-VII ( 7 ), Impurity-VIII ( 8 ), and Impurity-IX ( 9 ) formed during stability studies. Based on the results, a degradation pathway for the drug has been proposed and synthesis of Impurity-VII ( 7 ) is also discussed to ensure an in-depth understanding of LGP and its related degradation products and optimum performance during the lifetime of the product.

  10. Stability-indicating RP-HPLC method for the simultaneous determination of escitalopram oxalate and clonazepam.

    PubMed

    Kakde, Rajendra B; Satone, Dinesh D; Gadapayale, Kamalesh K; Kakde, Megha G

    2013-07-01

    The objective of the current study was to develop a validated, specific stability-indicating reversed-phase liquid chromatographic (LC) method for the quantitative determination of escitalopram oxalate and clonazepam and their related substances in bulk drugs and pharmaceutical dosage forms in the presence of degradation products. Forced degradation studies were performed on the pure drugs of escitalopram oxalate and clonazepam, as per the stress conditions prescribed by the International Conference on Harmonization (ICH) using acid, base, oxidation, thermal stress and photolytic degradation to show the stability-indicating power of the method. Significant degradation was observed during acid and alkaline hydrolysis and no degradation was observed in other stress conditions. The chromatographic method was optimized using the samples generated from forced degradation studies. Good resolution between the peaks corresponded to the active pharmaceutical ingredients, escitalopram oxalate and clonazepam, and degradation products from the analyte were achieved on an ODS Hypersil C18 column (250 × 4.6 mm) using a mobile phase consisting of a mixture of acetonitrile-50 mM phosphate buffer + 10 mM triethylamine (70:30, v/v). The detection was conducted at 268 nm. The limit of detection and the limit of quantitation for escitalopram oxalate and clonazepam were established. The stress test solutions were assayed against the qualified working standards of escitalopram oxalate and clonazepam, which indicated that the developed LC method was stability-indicating. Validation of the developed LC method was conducted as per ICH requirements. The developed LC method was found to be suitable to check the quality of bulk samples of escitalopram oxalate and clonazepam.

  11. A Stability-Indicating HPLC Method for the Determination of Nitrosylcobalamin (NO-Cbl), a Novel Vitamin B12 Analog.

    PubMed

    Dunphy, Michael J; Sysel, Annette M; Lupica, Joseph A; Griffith, Kristie; Sherrod, Taylor; Bauer, Joseph A

    2014-04-01

    Nitrosylcobalamin (NO-Cbl), a novel vitamin B 12 analog and anti-tumor agent, functions as a biologic 'Trojan horse', utilizing the vitamin B 12 transcobalamin II transport protein and cell surface receptor to specifically target cancer cells. a stability-indicating HPLC method was developed for the detection of NO-Cbl during forced degradation studies. This method utilized an ascentis ® RP-amide (150 mm × 4.6 mm, 5 μm) column at 35 °C with a mobile phase (1.0 mL min -1 ) combining a gradient of methanol and an acetate buffer at pH 6.0. Detection wavelengths of 450 and 254 nm were used to detect corrin and non-corrin-based products, respectively. NO-Cbl, synthesized from hydroxocobalamin and pure nitric oxide gas, was subjected to degradative stress conditions including oxidation, hydrolysis and thermal and radiant energy challenge. The method was validated by assessing linearity, accuracy, precision, detection and quantitation limits and robustness. The method was applied successfully for purity assessment of synthesized NO-Cbl and for the determination of NO-Cbl during kinetic studies in aqueous solution and in solid-state degradation assessments. This HPLC method is suitable for the separation of cobalamins in aqueous and methanolic solutions, for routine detection of NO-Cbl and for purity assessment of synthesized NO-Cbl. additionally, this method has potential application in identification and monitoring of diseases involving altered nitric oxide homeostasis where vitamin B 12 therapy is utilized to scavenge excess nitric oxide, subsequently resulting in the in vivo production of NO-Cbl.

  12. A Stability-Indicating HPLC Method for the Determination of Nitrosylcobalamin (NO-Cbl), a Novel Vitamin B12 Analog

    PubMed Central

    Dunphy, Michael J.; Sysel, Annette M.; Lupica, Joseph A.; Griffith, Kristie; Sherrod, Taylor

    2014-01-01

    Nitrosylcobalamin (NO-Cbl), a novel vitamin B12 analog and anti-tumor agent, functions as a biologic ‘Trojan horse’, utilizing the vitamin B12 transcobalamin II transport protein and cell surface receptor to specifically target cancer cells. a stability-indicating HPLC method was developed for the detection of NO-Cbl during forced degradation studies. This method utilized an ascentis® RP-amide (150 mm × 4.6 mm, 5 μm) column at 35 °C with a mobile phase (1.0 mL min−1) combining a gradient of methanol and an acetate buffer at pH 6.0. Detection wavelengths of 450 and 254 nm were used to detect corrin and non-corrin-based products, respectively. NO-Cbl, synthesized from hydroxocobalamin and pure nitric oxide gas, was subjected to degradative stress conditions including oxidation, hydrolysis and thermal and radiant energy challenge. The method was validated by assessing linearity, accuracy, precision, detection and quantitation limits and robustness. The method was applied successfully for purity assessment of synthesized NO-Cbl and for the determination of NO-Cbl during kinetic studies in aqueous solution and in solid-state degradation assessments. This HPLC method is suitable for the separation of cobalamins in aqueous and methanolic solutions, for routine detection of NO-Cbl and for purity assessment of synthesized NO-Cbl. additionally, this method has potential application in identification and monitoring of diseases involving altered nitric oxide homeostasis where vitamin B12 therapy is utilized to scavenge excess nitric oxide, subsequently resulting in the in vivo production of NO-Cbl. PMID:24855323

  13. Stability Indicating HPLC Determination of Risperidone in Bulk Drug and Pharmaceutical Formulations

    PubMed Central

    Dedania, Zarna R.; Dedania, Ronak R.; Sheth, Navin R.; Patel, Jigar B.; Patel, Bhavna

    2011-01-01

    The objective of the current study was to develop a validated stability-indicating assay method (SIAM) for risperidone after subjecting it to forced decomposition under hydrolysis, oxidation, photolysis, and thermal stress conditions. The liquid chromatographic separation was achieved isocratically on a symmetry C18 column (5 μm size, 250 mm × 4.6 mm i.d.) using a mobile phase containing methanol: acetonitrile (80 : 20, v/v) at a flow rate of 1 mL/min and UV detection at 280 nm. Retention time of risperidone was found to be 3.35 ± 0.01. The method was linear over the concentration range of 10–60 μg/mL(r 2 = 0.998) with a limit of detection and quantitation of 1.79 and 5.44 μg/mL, respectively. The method has the requisite accuracy, specificity, sensitivity, and precision to assay risperidone in bulk form and pharmaceutical dosage forms. Degradation products resulting from the stress studies did not interfere with the detection of Risperidone, and the assay is thus stability indicating. PMID:22007220

  14. Validation of a high performance liquid chromatography method for the stabilization of epigallocatechin gallate.

    PubMed

    Fangueiro, Joana F; Parra, Alexander; Silva, Amélia M; Egea, Maria A; Souto, Eliana B; Garcia, Maria L; Calpena, Ana C

    2014-11-20

    Epigallocatechin gallate (EGCG) is a green tea catechin with potential health benefits, such as anti-oxidant, anti-carcinogenic and anti-inflammatory effects. In general, EGCG is highly susceptible to degradation, therefore presenting stability problems. The present paper was focused on the study of EGCG stability in HEPES (N-2-hydroxyethylpiperazine-N'-2-ethanesulfonic acid) medium regarding the pH dependency, storage temperature and in the presence of ascorbic acid a reducing agent. The evaluation of EGCG in HEPES buffer has demonstrated that this molecule is not able of maintaining its physicochemical properties and potential beneficial effects, since it is partially or completely degraded, depending on the EGCG concentration. The storage temperature of EGCG most suitable to maintain its structure was shown to be the lower values (4 or -20 °C). The pH 3.5 was able to provide greater stability than pH 7.4. However, the presence of a reducing agent (i.e., ascorbic acid) was shown to provide greater protection against degradation of EGCG. A validation method based on RP-HPLC with UV-vis detection was carried out for two media: water and a biocompatible physiological medium composed of Transcutol®P, ethanol and ascorbic acid. The quantification of EGCG for purposes, using pure EGCG, requires a validated HPLC method which could be possible to apply in pharmacokinetic and pharmacodynamics studies. Copyright © 2014. Published by Elsevier B.V.

  15. Identification and quantification of flavonoids and chromes in Baeckea frutescens by using HPLC coupled with diode-array detection and quadruple time-of-flight mass spectrometry.

    PubMed

    Jia, Bei-Xi; Huangfu, Qian-Qian; Ren, Feng-Xiao; Jia, Lu; Zhang, Yan-Bing; Liu, Hong-Min; Yang, Jie; Wang, Qiang

    2015-01-01

    This article marks the first report on high-performance liquid chromatography (HPLC) coupled with diode-array detection (DAD) and quadruple time-of-flight mass spectrometry (Q-TOF/MS) for the identification and quantification of main bioactive constituents in Baeckea frutescens. In total, 24 compounds were identified or tentatively characterised based on their retention behaviours, UV profiles and MS fragment information. Furthermore, a validated method with good linearity, sensitivity, precision, stability, repeatability and accuracy was successfully applied for simultaneous determination of five flavonoids and one chromone in different plant parts of B. frutescens collected at different harvest times, and their dynamic contents revealed the appropriate harvest times. The established HPLC-DAD-Q-TOF/MS using multi-bioactive markers was proved to be a validated strategy for the quality evaluation on both raw materials and related products of B. frutescens.

  16. High performance liquid chromatography used for quality control of Achyranthis Radix.

    PubMed

    Zhao, Bing Tian; Jeong, Su Yang; Moon, Dong Cheul; Son, Kun Ho; Son, Jong Keun; Woo, Mi Hee

    2012-08-01

    To establish a standard of quality control and to identify reliable Achyranthis Radix, three phytoecdysones including ecdysterone (1), 25R-inokosterone (2) and 25S-inokosterone (3) were determined by quantitative HPLC/UV analysis. Three phytoecdysones were separated with an YMC J'sphere ODS C(18) column (250 mm × 4.6 mm, 4 μm) by isocratic elution using 0.1% formic acid in water and acetonitrile (85:15, v/v%) as the mobile phase. The flow rate was 1.0 mL/min and the UV detector wavelength was set at 245 nm. The standards were quantified by HPLC/UV from Achyranthes bidentata Blume and Achyranthes japonica Nakai, as well as Cyathula capitata Moq. and Cyathula officinalis Kuan, which are of a different genus but are comparative herbs. The method was successfully used in the analysis of Achyranthis Radix of different geographical origin or genera with relatively simple conditions and procedures, and the assay results were satisfactory for linearity, recovery, precision, accuracy, stability and robustness. The HPLC analytical method for pattern recognition analysis was validated by repeated analysis of eighteen A. bidentata Blume samples and ten A. japonica Nakai samples. The results indicate that the established HPLC/UV method is suitable for quantitation and pattern recognition analyses for quality evaluation of Achyranthis Radix.

  17. Development and validation of a new method to simultaneously quantify triazoles in plasma spotted on dry sample spot devices and analysed by HPLC-MS.

    PubMed

    Baietto, Lorena; D'Avolio, Antonio; Marra, Cristina; Simiele, Marco; Cusato, Jessica; Pace, Simone; Ariaudo, Alessandra; De Rosa, Francesco Giuseppe; Di Perri, Giovanni

    2012-11-01

    Therapeutic drug monitoring (TDM) of triazoles is widely used in clinical practice to optimize therapy. TDM is limited by technical problems and cost considerations, such as sample storage and dry-ice shipping. We aimed to develop and validate a new method to analyse itraconazole, posaconazole and voriconazole in plasma spotted on dry sample spot devices (DSSDs) and to quantify them by an HPLC system. Extraction from DSSDs was done using n-hexane/ethyl acetate and ammonia solution. Samples were analysed using HPLC with mass spectrometry (HPLC-MS). Accuracy and precision were assayed by inter- and intra-day validation. The stability of triazoles in plasma spotted on DSSDs was investigated at room temperature for 1 month. The method was compared with a validated standard HPLC method for quantification of triazoles in human plasma. Mean inter- and intra-day accuracy and precision were <15% for all compounds. Triazoles were stable for 2 weeks at room temperature. The method was linear (r(2) > 0.999) in the range 0.031-8 mg/L for itraconazole and posaconazole, and 0.058-15 mg/L for voriconazole. High sensitivity was observed; limits of detection were 0.008, 0.004 and 0.007 mg/L for itraconazole, posaconazole and voriconazole, respectively. A high degree of correlation (r(2) > 0.94) was obtained between the DSSD method and the standard method of analysis. The method that we developed and validated to quantify triazoles in human plasma spotted on DSSDs is accurate and precise. It overcomes problems related to plasma sample storage and shipment, allowing TDM to be performed in a cheaper and safer manner.

  18. [Study on arsenic speciation changes in crude and processed traditional Chinese medicines by HPLC-ICP-MS].

    PubMed

    Jin, Peng-fei; Wu, Xue-jun; Zou, Ding; Kuang, Yong-mei; Hu, Xin; Jiang, Wen-qing; Sun, Chun-hua

    2011-03-01

    A HPLC-ICP-MS method for simultaneous determination of As(III), As(V), MMA and DMA in traditional Chinese medicines (TCMs) was established, and the contents of As(III), As(V), MMA and DMA in a TCM with high total arsenic content (Cordyceps) and 5 crude and processed TCMs (Radix Astragali, Radix et Rhizoma Rhei, Radix Scutellariae, Radix Polygoni Multiflori and Radix Rehmanniae) were determined and analyzed. The method validation indicated that the correlative coefficients (r) for all speciations were bigger than 0.9984; the limits of quantitation (LOQ) were from 0.8 to 1.0 microg x L(-1); the reproducibility and stability were satisfactory with all RSDs less than 10%; the spiked recoveries ranged from 82.40% to 119.5%. The results of samples analysis showed that the inorganic arsenic (As(III) and As(V)) was the dominating speciation in the tested TCMs; MMA and DMA were not found in all plant resourced TCMs, but MMA was found in Cordyceps; all the tested TCMs indicated a content increasing of inorganic arsenic after processing.

  19. Stability indicating HPLC-DAD method for analysis of Ketorolac binary and ternary mixtures in eye drops: Quantitative analysis in rabbit aqueous humor.

    PubMed

    El Yazbi, Fawzy A; Hassan, Ekram M; Khamis, Essam F; Ragab, Marwa A A; Hamdy, Mohamed M A

    2017-11-15

    Ketorolac tromethamine (KTC) with phenylephrine hydrochloride (PHE) binary mixture (mixture 1) and their ternary mixture with chlorpheniramine maleate (CPM) (mixture 2) were analyzed using a validated HPLC-DAD method. The developed method was suitable for the in vitro as well as quantitative analysis of the targeted mixtures in rabbit aqueous humor. The analysis in dosage form (eye drops) was a stability indicating one at which drugs were separated from possible degradation products arising from different stress conditions (in vitro analysis). For analysis in aqueous humor, Guaifenesin (GUF) was used as internal standard and the method was validated according to FDA regulation for analysis in biological fluids. Agilent 5 HC-C18(2) 150×4.6mm was used as stationary phase with a gradient eluting solvent of 20mM phosphate buffer pH 4.6 containing 0.2% triethylamine and acetonitrile. The drugs were resolved with retention times of 2.41, 5.26, 7.92 and 9.64min for PHE, GUF, KTC and CPM, respectively. The method was sensitive and selective to analyze simultaneously the three drugs in presence of possible forced degradation products and dosage form excipients (in vitro analysis) and also with the internal standard, in presence of aqueous humor interferences (analysis in biological fluid), at a single wavelength (261nm). No extraction procedure was required for analysis in aqueous humor. The simplicity of the method emphasizes its capability to analyze the drugs in vivo (in rabbit aqueous humor) and in vitro (in pharmaceutical formulations). Copyright © 2017 Elsevier B.V. All rights reserved.

  20. Stability-Indicating Related Substances HPLC Method for Droxidopa and Characterization of Related Substances Using LC-MS and NMR.

    PubMed

    Kumar, Thangarathinam; Ramya, Mohandass; Arockiasamy Xavier, S J

    2016-11-01

    Stress degradation studies using high-performance liquid chromatography (HPLC) was performed and validated for Droxidopa (L-DOPS). Droxidopa was susceptible to acid hydrolysis (0.1 N HCl), alkaline hydrolysis (0.15 N NaOH) and thermal degradation (105°C). It was found to be resistant to white light, oxidation and UV light exposure (72 h). The thermal, acid and alkali degradation impurities were detected with the retention time (RT) of 12.7, 19.25 and 22.95 min. Our HPLC method detected process impurities (2R,3R)-2-amino-3-(3,4-dihydroxyphenyl)-3-hydroxypropionic acid (Impurity H), N-Hydroxypthalimide (Impurity N), (2R,3S)-2-amino-3-(benzo[d][1,3]dioxol-5-yl)-3-hydroxypropionic acid (Impurity L) and L-threo n-phthaloyl-3-(3, 4-dihydroxyphenyl)-serine (Intermediate) with RTs of 3.48, 15.5, 25.76 and 28.0 min. The related substances were further characterized and confirmed by liquid chromatography-mass spectroscopy (LC-MS), and nuclear magnetic resonance spectroscopy analysis. Our HPLC method detected up to 0.05 µg/mL of Droxidopa with S/N > 3.0 and quantified up to 0.10 µg /mL of Droxidopa with S/N ratio > 10.0. Droxidopa was highly stable for 12 h after its preparation for HPLC analysis. Our newly developed HPLC method was highly precise, specific, reliable and accurate for the analysis of Droxidopa and its related substances. © The Author 2016. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.

  1. A high-performance liquid chromatography method for the serotonin release assay is equivalent to the radioactive method.

    PubMed

    Sono-Koree, N K; Crist, R A; Frank, E L; Rodgers, G M; Smock, K J

    2016-02-01

    The serotonin release assay (SRA) is considered the gold standard laboratory test for heparin-induced thrombocytopenia (HIT). The historic SRA method uses platelets loaded with radiolabeled serotonin to evaluate platelet activation by HIT immune complexes. However, a nonradioactive method is desirable. We report the performance characteristics of a high-performance liquid chromatography (HPLC) SRA method. We validated the performance characteristics of an HPLC-SRA method, including correlation with a reference laboratory using the radioactive method. Serotonin released from reagent platelets was quantified by HPLC using fluorescent detection. Results were expressed as % release and classified as positive, negative, or indeterminate based on previously published cutoffs. Serum samples from 250 subjects with suspected HIT were tested in the HPLC-SRA and with the radioactive method. Concordant classifications were observed in 230 samples (92%). Sera from 41 healthy individuals tested negative. Between-run imprecision studies showed standard deviation of <6 (% release) for positive, weak positive, and negative serum pools. Stability studies demonstrated stability after two freeze-thaw cycles or up to a week of refrigeration. The HPLC-SRA has robust performance characteristics, equivalent to the historic radioactive method, but avoids the complexities of working with radioactivity. © 2015 John Wiley & Sons Ltd.

  2. Development and validation of stability indicating the RP-HPLC method for the estimation of related compounds of guaifenesin in pharmaceutical dosage forms.

    PubMed

    Reddy, Sunil Pingili; Babu, K Sudhakar; Kumar, Navneet; Sekhar, Y V V Sasi

    2011-10-01

    A stability-indicating gradient reverse phase liquid chromatographic (RP-LC) method was developed for the quantitative determination of related substances of guaifenesin in pharmaceutical formulations. The baseline separation for guaifenesin and all impurities was achieved by utilizing a Water Symmetry C18 (150 mm × 4.6 mm) 5 μm column particle size and a gradient elution method. The mobile phase A contains a mixture of 0.02 M KH2PO4 (pH 3.2) and methanol in the ratio of 90:10 v/v, while the mobile phase B contains 0.02 M KH2PO4 (pH 3.2) and methanol in the ratio of 10:90 v/v, respectively. The flow rate of the mobile phase was 0.8 ml/min with a column temperature of 25°C and detection wavelength at 273 nm. Guaifenesin was subjected to the stress conditions of oxidative, acid, base, hydrolytic, thermal, and photolytic degradation. The developed method was validated as per ICH guidelines with respect to specificity, linearity, limit of detection and quantification, accuracy, precision, and robustness.

  3. Development and validation of stability indicating the RP-HPLC method for the estimation of related compounds of guaifenesin in pharmaceutical dosage forms

    PubMed Central

    Reddy, Sunil Pingili; Babu, K. Sudhakar; Kumar, Navneet; Sekhar, Y. V. V. Sasi

    2011-01-01

    Aim and background: A stability-indicating gradient reverse phase liquid chromatographic (RP-LC) method was developed for the quantitative determination of related substances of guaifenesin in pharmaceutical formulations. Materials and methods: The baseline separation for guaifenesin and all impurities was achieved by utilizing a Water Symmetry C18 (150 mm × 4.6 mm) 5 μm column particle size and a gradient elution method. The mobile phase A contains a mixture of 0.02 M KH2PO4 (pH 3.2) and methanol in the ratio of 90:10 v/v, while the mobile phase B contains 0.02 M KH2PO4 (pH 3.2) and methanol in the ratio of 10:90 v/v, respectively. The flow rate of the mobile phase was 0.8 ml/min with a column temperature of 25°C and detection wavelength at 273 nm. Results: Guaifenesin was subjected to the stress conditions of oxidative, acid, base, hydrolytic, thermal, and photolytic degradation. Conclusion: The developed method was validated as per ICH guidelines with respect to specificity, linearity, limit of detection and quantification, accuracy, precision, and robustness. PMID:23781462

  4. Validation of a Stability-Indicating Method for Methylseleno-l-Cysteine (l-SeMC)

    PubMed Central

    Canady, Kristin; Cobb, Johnathan; Deardorff, Peter; Larson, Jami; White, Jonathan M.; Boring, Dan

    2016-01-01

    Methylseleno-l-cysteine (l-SeMC) is a naturally occurring amino acid analogue used as a general dietary supplement and is being explored as a chemopreventive agent. As a known dietary supplement, l-SeMC is not regulated as a pharmaceutical and there is a paucity of analytical methods available. To address the lack of methodology, a stability-indicating method was developed and validated to evaluate l-SeMC as both the bulk drug and formulated drug product (400 µg Se/capsule). The analytical approach presented is a simple, nonderivatization method that utilizes HPLC with ultraviolet detection at 220 nm. A C18 column with a volatile ion-pair agent and methanol mobile phase was used for the separation. The method accuracy was 99–100% from 0.05 to 0.15 mg/mL l-SeMC for the bulk drug, and 98–99% from 0.075 to 0.15 mg/mL l-SeMC for the drug product. Method precision was <1% for the bulk drug and was 3% for the drug product. The LOQ was 0.1 µg/mL l-SeMC or 0.002 µg l-SeMC on column. PMID:26199341

  5. Development and validation of stability-indicating high performance liquid chromatography method to analyze gatifloxacin in bulk drug and pharmaceutical preparations.

    PubMed

    Aljuffali, Ibrahim A; Kalam, Mohd Abul; Sultana, Yasmin; Imran, Ahamad; Alshamsan, Aws

    2015-01-01

    Quantitative determination of gatifloxacin in tablets, solid lipid nanoparticles (SLNs) and eye-drops using a very simple and rapid chromatographic technique was validated and developed. Formulations were analyzed using a reverse phase SUPELCO® 516 C-18-DB, 50306-U, HPLC column (250 mm × 4.6 mm, 5 μm) and a mobile phase consisting of disodium hydrogen phosphate buffer:acetonitrile (75:25, v/v) and with orthophosphoric acid pH was adjusted to 3.3 The flow rate was 1.0 mL/min and analyte concentrations were measured using a UV-detector at 293 nm. The analyses were performed at room temperature (25 ± 2 °C). Gatifloxacin was separated in all the formulations within 2.767 min. There were linear calibration curves over a concentration range of 4.0-40 μg.mL(-1) and correlation coefficients of 0.9998 with an average recovery above 99.91%. Detection of analyte from different dosage forms at the same Rt indicates the specificity and stability of the developed method.

  6. Least-Squares Regression and Spectral Residual Augmented Classical Least-Squares Chemometric Models for Stability-Indicating Analysis of Agomelatine and Its Degradation Products: A Comparative Study.

    PubMed

    Naguib, Ibrahim A; Abdelrahman, Maha M; El Ghobashy, Mohamed R; Ali, Nesma A

    2016-01-01

    Two accurate, sensitive, and selective stability-indicating methods are developed and validated for simultaneous quantitative determination of agomelatine (AGM) and its forced degradation products (Deg I and Deg II), whether in pure forms or in pharmaceutical formulations. Partial least-squares regression (PLSR) and spectral residual augmented classical least-squares (SRACLS) are two chemometric models that are being subjected to a comparative study through handling UV spectral data in range (215-350 nm). For proper analysis, a three-factor, four-level experimental design was established, resulting in a training set consisting of 16 mixtures containing different ratios of interfering species. An independent test set consisting of eight mixtures was used to validate the prediction ability of the suggested models. The results presented indicate the ability of mentioned multivariate calibration models to analyze AGM, Deg I, and Deg II with high selectivity and accuracy. The analysis results of the pharmaceutical formulations were statistically compared to the reference HPLC method, with no significant differences observed regarding accuracy and precision. The SRACLS model gives comparable results to the PLSR model; however, it keeps the qualitative spectral information of the classical least-squares algorithm for analyzed components.

  7. Development and optimization of SPE-HPLC-UV/ELSD for simultaneous determination of nine bioactive components in Shenqi Fuzheng Injection based on Quality by Design principles.

    PubMed

    Wang, Lu; Qu, Haibin

    2016-03-01

    A method combining solid phase extraction, high performance liquid chromatography, and ultraviolet/evaporative light scattering detection (SPE-HPLC-UV/ELSD) was developed according to Quality by Design (QbD) principles and used to assay nine bioactive compounds within a botanical drug, Shenqi Fuzheng Injection. Risk assessment and a Plackett-Burman design were utilized to evaluate the impact of 11 factors on the resolutions and signal-to-noise of chromatographic peaks. Multiple regression and Pareto ranking analysis indicated that the sorbent mass, sample volume, flow rate, column temperature, evaporator temperature, and gas flow rate were statistically significant (p < 0.05) in this procedure. Furthermore, a Box-Behnken design combined with response surface analysis was employed to study the relationships between the quality of SPE-HPLC-UV/ELSD analysis and four significant factors, i.e., flow rate, column temperature, evaporator temperature, and gas flow rate. An analytical design space of SPE-HPLC-UV/ELSD was then constructed by calculated Monte Carlo probability. In the presented approach, the operating parameters of sample preparation, chromatographic separation, and compound detection were investigated simultaneously. Eight terms of method validation, i.e., system-suitability tests, method robustness/ruggedness, sensitivity, precision, repeatability, linearity, accuracy, and stability, were accomplished at a selected working point. These results revealed that the QbD principles were suitable in the development of analytical procedures for samples in complex matrices. Meanwhile, the analytical quality and method robustness were validated by the analytical design space. The presented strategy provides a tutorial on the development of a robust QbD-compliant quantitative method for samples in complex matrices.

  8. Development and Validation of a Precise, Single HPLC Method for the Determination of Tolperisone Impurities in API and Pharmaceutical Dosage Forms.

    PubMed

    Raju, Thummala Veera Raghava; Seshadri, Raja Kumar; Arutla, Srinivas; Mohan, Tharlapu Satya Sankarsana Jagan; Rao, Ivaturi Mrutyunjaya; Nittala, Someswara Rao

    2013-01-01

    A novel, sensitive, stability-indicating HPLC method has been developed for the quantitative estimation of Tolperisone-related impurities in both bulk drugs and pharmaceutical dosage forms. Effective chromatographic separation was achieved on a C18 stationary phase with a simple mobile phase combination delivered in a simple gradient programme, and quantitation was by ultraviolet detection at 254 nm. The mobile phase consisted of a buffer and acetonitrile delivered at a flow rate 1.0 ml/min. The buffer consisted of 0.01 M potassium dihydrogen phosphate with the pH adjusted to 8.0 by using diethylamine. In the developed HPLC method, the resolution between Tolperisone and its four potential impurities was found to be greater than 2.0. Regression analysis showed an R value (correlation coefficient) of greater than 0.999 for the Tolperisone impurities. This method was capable of detecting all four impurities of Tolperisone at a level of 0.19 μg/mL with respect to the test concentration of 1000 μg/mL for a 10 µl injection volume. The tablets were subjected to the stress conditions of hydrolysis, oxidation, photolysis, and thermal degradation. Considerable degradation was found to occur in base hydrolysis, water hydrolysis, and oxidation. The stress samples were assayed against a qualified reference standard and the mass balance was found to be close to 100%. The established method was validated and found to be linear, accurate, precise, specific, robust, and rugged.

  9. A validated RP-HPLC method for simultaneous determination of propranolol and valsartan in bulk drug and gel formulation

    PubMed Central

    Imam, Syed Sarim; Ahad, Abdul; Aqil, Mohammed; Sultana, Yasmin; Ali, Asgar

    2013-01-01

    Objective: A simple, precise, and stability indicating high performance liquid chromatography (HPLC) method was developed and validated for the simultaneous determination of propranolol hydrochloride and valsartan in pharmaceutical dosage form. Materials and Methods: The method involves the use of easily available inexpensive laboratory reagents. The separation was achieved on Hypersil ODS C-18 column (250*4.6 mm, i.d., 5 μm particle size) with isocratic flow with UV detector. The mobile phase at a flow rate of 1.0 mL/min consisted of acetonitrile, methanol, and 0.01 M disodium hydrogen phosphate (pH 3.5) in the ratio of 50:35:15 v/v. Results: A linear response was observed over the concentration range 5-50 μg/mL of propranolol and the concentration range 4-32 μg/mL of valsartan. Limit of detection and limit of quantitation for propranolol were 0.27 μg/mL and 0.85 μg/mL, and for valsartan were 0.45 μg/mL and 1.39 μg/mL, respectively. The method was successfully validated in accordance to ICH guidelines acceptance criteria for linearity, accuracy, precision, specificity, robustness. Conclusion: The analysis concluded that the method was selective for simultaneous estimation of propranolol and valsartan can be potentially used for the estimation of these drugs in combined dosage form. PMID:23559826

  10. A Validated Stability Indicating RP-HPLC Method for the Determination of Emtricitabine, Tenofovir Disoproxil Fumarate, Elvitegravir and Cobicistat in Pharmaceutical Dosage Form

    PubMed Central

    Runja, Chinnalalaiah; Ravi Kumar, Pigili; Avanapu, Srinivasa Rao

    2016-01-01

    A new simple, rapid stability indicating assay method has been developed and validated for the determination of emtricitabine, tenofovir disoproxil fumarate, elvitegravir and cobicistat using reverse-phase high-performance liquid chromatography in their pharmaceutical dosage form. The chromatographic separation was performed on an ODS column (250 × 4.6 mm, 5 µm) using mobile phase A (potassium dihydrogen orthophosphate, pH adjusted to 2.5) and mobile phase B (acetonitrile) in the ratio of 55:45% v/v at a flow rate of 1 mL/min. The analytes were detected at 250 nm. The method was found to be linear in the concentration range of 2–12 µg/mL for EMT, 3–18 µg/mL for TNDF, 1.5–9 µg/mL for ELV and COB, with the coefficient value (R2) of >0.9990. The accuracy was measured via recovery studies and found to be acceptable, and the percentage recoveries were found in the range of 99.93–100.08 ± 0.5%. Forced degradation studies were also conducted, and the drugs were subjected to various stress conditions such as acid hydrolysis, base hydrolysis, oxidative, photolytic and thermal degradation. The proposed method was successfully validated and applied for the quantitative estimation of these drugs in both bulk and tablet dosage forms. PMID:26865655

  11. Development and validation of a single robust HPLC method for the characterization of a pharmaceutical starting material and impurities from three suppliers using three separate synthetic routes.

    PubMed

    Sheldon, E M; Downar, J B

    2000-08-15

    Novel approaches to the development of analytical procedures for monitoring incoming starting material in support of chemical/pharmaceutical processes are described. High technology solutions were utilized for timely process development and preparation of high quality clinical supplies. A single robust HPLC method was developed and characterized for the analysis of the key starting material from three suppliers. Each supplier used a different process for the preparation of this material and, therefore, each suppliers' material exhibited a unique impurity profile. The HPLC method utilized standard techniques acceptable for release testing in a QC/manufacturing environment. An automated experimental design protocol was used to characterize the robustness of the HPLC method. The method was evaluated for linearity, limit of quantitation, solution stability, and precision of replicate injections. An LC-MS method that emulated the release HPLC method was developed and the identities of impurities were mapped between the two methods.

  12. Multivariate optimization and validation of an analytical methodology by RP-HPLC for the determination of losartan potassium in capsules.

    PubMed

    Bonfilio, Rudy; Tarley, César Ricardo Teixeira; Pereira, Gislaine Ribeiro; Salgado, Hérida Regina Nunes; de Araújo, Magali Benjamim

    2009-11-15

    This paper describes the optimization and validation of an analytical methodology for the determination of losartan potassium in capsules by HPLC using 2(5-1) fractional factorial and Doehlert designs. This multivariate approach allows a considerable improvement in chromatographic performance using fewer experiments, without additional cost for columns or other equipment. The HPLC method utilized potassium phosphate buffer (pH 6.2; 58 mmol L(-1))-acetonitrile (65:35, v/v) as the mobile phase, pumped at a flow rate of 1.0 mL min(-1). An octylsilane column (100 mm x 4.6mm i.d., 5 microm) maintained at 35 degrees C was used as the stationary phase. UV detection was performed at 254 nm. The method was validated according to the ICH guidelines, showing accuracy, precision (intra-day relative standard deviation (R.S.D.) and inter-day R.S.D values <2.0%), selectivity, robustness and linearity (r=0.9998) over a concentration range from 30 to 70 mg L(-1) of losartan potassium. The limits of detection and quantification were 0.114 and 0.420 mg L(-1), respectively. The validated method may be used to quantify losartan potassium in capsules and to determine the stability of this drug.

  13. New Stability-Indicating RP-HPLC Method for Determination of Diclofenac Potassium and Metaxalone from their Combined Dosage Form

    PubMed Central

    Panda, Sagar Suman; Patanaik, Debasis; Ravi Kumar, Bera V. V.

    2012-01-01

    A simple, precise and accurate isocratic RP-HPLC stability-indicating assay method has been developed to determine diclofenac potassium and metaxalone in their combined dosage forms. Isocratic separation was achieved on a Hibar-C18, Lichrosphere-100® (250 mm × 4.6 mm i.d., particle size 5 μm) column at room temperature in isocratic mode, the mobile phase consists of methanol: water (80:20, v/v) at a flow rate of 1.0 ml/min, the injection volume was 20 μl and UV detection was carried out at 280nm. The drug was subjected to acid and alkali hydrolysis, oxidation, photolysis and heat as stress conditions. The method was validated for specificity, linearity, precision, accuracy, robustness and system suitability. The method was linear in the drug concentration range of 2.5–30 μg/ml and 20–240 μg/ml for diclofenac potassium and metaxalone, respectively. The precision (RSD) of six samples was 0.83 and 0.93% for repeatability, and the intermediate precision (RSD) among six-sample preparation was 1.63 and 0.49% for diclofenac potassium and metaxalone, respectively. The mean recoveries were between 100.99–102.58% and 99.97–100.01% for diclofenac potassium and metaxalone, respectively. The proposed method can be used successfully for routine analysis of the drug in bulk and combined pharmaceutical dosage forms. PMID:22396909

  14. Analysis of sesquiterpene lactones, lignans, and flavonoids in wormwood (Artemisia absinthium L.) using high-performance liquid chromatography (HPLC)-mass spectrometry, reversed phase HPLC, and HPLC-solid phase extraction-nuclear magnetic resonance.

    PubMed

    Aberham, Anita; Cicek, Serhat Sezai; Schneider, Peter; Stuppner, Hermann

    2010-10-27

    Today, the medicinal use of wormwood (Artemisia absinthium) is enjoying a resurgence of popularity. This study presents a specific and validated high-performance liquid chromatography (HPLC)-diode array detection method for the simultaneous determination and quantification of bioactive compounds in wormwood and commercial preparations thereof. Five sesquiterpene lactones, two lignans, and a polymethoxylated flavonoid were baseline separated on RP-18 material, using a solvent gradient consisting of 0.085% (v/v) o-phosphoric acid and acetonitrile. The flow rate was 1.0 mL/min, and chromatograms were recorded at 205 nm. The stability of absinthin was tested exposing samples to light, moisture, and different temperatures. Methanolic and aqueous solutions of absinthin were found to be stable for up to 6 months. This was also the case when the solid compound was kept in the refrigerator at -35 °C. In contrast, the colorless needles, when stored at room temperature, turned yellow. Three degradation compounds (anabsin, anabsinthin, and the new dimer 3'-hydroxyanabsinthin) were identified by HPLC-mass spectrometry and HPLC-solid-phase extraction-nuclear magnetic resonance and quantified by the established HPLC method.

  15. Validation of a Stability-Indicating Method for Methylseleno-L-Cysteine (L-SeMC).

    PubMed

    Canady, Kristin; Cobb, Johnathan; Deardorff, Peter; Larson, Jami; White, Jonathan M; Boring, Dan

    2016-01-01

    Methylseleno-L-cysteine (L-SeMC) is a naturally occurring amino acid analogue used as a general dietary supplement and is being explored as a chemopreventive agent. As a known dietary supplement, L-SeMC is not regulated as a pharmaceutical and there is a paucity of analytical methods available. To address the lack of methodology, a stability-indicating method was developed and validated to evaluate L-SeMC as both the bulk drug and formulated drug product (400 µg Se/capsule). The analytical approach presented is a simple, nonderivatization method that utilizes HPLC with ultraviolet detection at 220 nm. A C18 column with a volatile ion-pair agent and methanol mobile phase was used for the separation. The method accuracy was 99-100% from 0.05 to 0.15 mg/mL L-SeMC for the bulk drug, and 98-99% from 0.075 to 0.15 mg/mL L-SeMC for the drug product. Method precision was <1% for the bulk drug and was 3% for the drug product. The LOQ was 0.1 µg/mL L-SeMC or 0.002 µg L-SeMC on column. © The Author 2015. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.

  16. Determination of osthol and its metabolites in a phase I reaction system and the Caco-2 cell model by HPLC-UV and LC-MS/MS

    PubMed Central

    Yuan, Zhenting; Xu, Haiyan; Wang, Ke; Zhao, Zhonghua; Hu, Ming

    2012-01-01

    A straightforward and sensitive reversed-phase high-performance liquid chromatography (HPLC) assay was developed and validated for the analysis of osthol and its phase I metabolites (internal standard: umbelliferone). The method was validated for the determination of osthol with respect to selectivity, precision, linearity, limit of detection, recovery, and stability. The linear response range was 0.47 ~ 60 μM, and the average recoveries ranged from 98 to 101%. The inter-day and intra-day relative standard deviations were both less than 5%. Using this method, we showed that more than 80% of osthol was metabolized in 20 min in a phase I metabolic reaction system. Transport experiments in the Caco-2 cell culture model indicated that osthol was easily absorbed with high absorptive permeability (>10×10-6 cm/sec). The permeability did not display concentration-dependence or vectorial-dependence and is mildly temperature sensitive (activation energy less than 10 Kcal/mole), indicating passive mechanism of transport. When analyzed by LC-MS/MS, five metabolites were detected in a phase I reaction system and in the receiver side of a modified Caco-2 cell model, which was supplemented with the phase I reaction system. The major metabolites appeared to be desmethyl-osthol and multiple isomers of dehydro-osthol. In conclusion, a likely cause of poor osthol bioavailability is rapid phase I metabolism via the cytochrome P-450 pathways. PMID:19304430

  17. Development and validation of a stability-indicating high performance liquid chromatographic assay for benoxinate.

    PubMed

    Chorny, Michael; Levy, Daniel; Schumacher, Ilana; Lichaa, Chaim; Gruzman, Boris; Livshits, Oleg; Lomnicky, Yossi

    2003-04-24

    Benoxinate is a local anaesthetic used for ophthalmic applications. The aim of this study was to develop a rapid and simple stability-indicating method for the determination of benoxinate formulated for ophthalmic use, evaluate its long-term stability and identify its major degradation product. Benoxinate was eluted on a 10 microm Spherisorb phenyl column, 250 x 3.2 mm, with a mobile phase consisting of acetonitrile-buffer (pH 3.5) (35:65, v/v), pumped at 0.8 ml min(-1) flow rate. The buffer was composed of sodium dihydrogen phosphate (50 mM), sodium hydrogen sulfate (2.5 mM) and 1-heptanesulfonic acid sodium salt (5 mM). The analyte was quantified spectrophotometrically at 308 nm. The chromatograms of benoxinate formulations obtained by this method showed benoxinate (t = 4.5 min) well resolved from its degradation product (t = 2.3 min), which was separately identified by means of HPLC-MS as 4-amino-3-butoxybenzoic acid. The assay was demonstrated to have high accuracy, precision and linearity. The method was implemented in investigating the long-term stability of benoxinate 0.4% ophthalmic solutions. The method was found to be simple, quick and selective in determining benoxinate concentrations in fresh and aged preparations.

  18. Development and validation of a novel stability-indicating HPLC method for the quantitative determination of eleven related substances in ezetimibe drug substance and drug product.

    PubMed

    Luo, Zhiqiang; Deng, Zhongqing; Liu, Yang; Wang, Guopeng; Yang, Wenning; Hou, Chengbo; Tang, Minming; Yang, Ruirui; Zhou, Huaming

    2015-07-01

    Ezetimibe is a novel lipid-lowering agent that inhibits intestinal absorption of dietary and biliary cholesterol. In the present work, a simple, sensitive and reproducible gradient reverse phase high performance liquid chromatographic (RP-HPLC) method for separation and determination of the related substances of ezetimibe was developed and validated. Eleven potential process-related impurities (starting materials, (3S,4S,3'S)-isomer, degradants and byproducts) were identified in the crude samples. Tentative structures for all the impurities were assigned primarily based on comparison of their retention time and mass spectrometric data with that of available standards and references. This method can be applied to routine analysis in quality control of both bulk drugs and commercial tablets. Separation of all these compounds was performed on a Phenomenex Luna Phenyl-Hexyl (100mm×4.6mm, 5μm) analytical column. The mobile phase-A consists of acetonitrile-water (pH adjusted to 4.0 with phosphoric acid)-methanol at 15:75:10 (v/v/v), and mobile phase-B contains acetonitrile. The eluted compounds were monitored at 210nm. Ezetimibe was subjected to hydrolytic, acid, base, oxidative, photolytic and thermal stress conditions as per ICH serves to generate degradation products that can be used as a worst case to assess the analytical method performance. The drug showed extensive degradation in thermal, acid, oxidative, base and hydrolytic stress conditions, while it was stable to photolytic degradation conditions. The main degradation product formed under thermal, acid, oxidative, base and hydrolytic stress conditions corresponding to (2R,3R,6S)-N, 6-bis(4-fluorophenyl)-2-(4-hydroxyphenyl)-oxane-3-carboxamide (Ezetimibe tetrahydropyran impurity) was characterized by LC-MS/MS analysis. The degradation products were well resolved from the main peak and its impurities, thus proved the stability-indicating power of the method. The developed method was validated as per international conference on harmonization (ICH) guidelines with respect to specificity, linearity, limit of detection (LOD), limit of quantification (LOQ), accuracy, precision and robustness. Copyright © 2015 Elsevier B.V. All rights reserved.

  19. Development, Validation and Application of RP-HPLC Method: Simultaneous Determination of Antihistamine and Preservatives with Paracetamol in Liquid Formulations and Human Serum.

    PubMed

    Hasan, Najmul; Chaiharn, Mathurot; Toor, Umair Ali; Mirani, Zulfiqar Ali; Sajjad, Ghulam; Sher, Nawab; Aziz, Mubashir; Siddiqui, Farhan Ahmed

    2016-01-01

    In this article we describe development and validation of stability indicating, accurate, specific, precise and simple Ion-pairing RP-HPLC method for simultaneous determination of paracetamol and cetirizine HCl along with preservatives i.e. propylparaben, and methylparaben in pharmaceutical dosage forms of oral solution and in serum. Acetonitrile: Buffer: Sulfuric Acid (45:55:0.3 v/v/v) was the mobile phase at flow rate 1.0 mL min(-1) using a Hibar(®) Lichrosorb(®) C18 column and monitored at wavelength of 230nm. The averages of absolute and relative recoveries were found to be 99.3%, 99.5%, 99.8% and 98.7% with correlation coefficient of 0.9977, 0.9998, 0.9984, and 0.9997 for cetirizine HCl, paracetamol, methylparaben and Propylparaben respectively. The limit of quantification and limit of detection were in range of 0.3 to 2.7 ng mL(-1) and 0.1 to 0.8 ng mL(-1) respectively. Under stress conditions of acidic, basic, oxidative, and thermal degradation, maximum degradation was observed in basic and oxidative stress where a significant impact was observed while all drugs were found almost stable in the other conditions. The developed method was validated in accordance with ICH and AOAC guidelines. The proposed method was successfully applied to quantify amount of paracetamol, cetirizine HCl and two most common microbial preservatives in bulk, dosage form and physiological fluid.

  20. Development, Validation and Application of RP-HPLC Method: Simultaneous Determination of Antihistamine and Preservatives with Paracetamol in Liquid Formulations and Human Serum

    PubMed Central

    Hasan, Najmul; Chaiharn, Mathurot; Toor, Umair Ali; Mirani, Zulfiqar Ali; Sajjad, Ghulam; Sher, Nawab; Aziz, Mubashir; Siddiqui, Farhan Ahmed

    2016-01-01

    In this article we describe development and validation of stability indicating, accurate, specific, precise and simple Ion-pairing RP-HPLC method for simultaneous determination of paracetamol and cetirizine HCl along with preservatives i.e. propylparaben, and methylparaben in pharmaceutical dosage forms of oral solution and in serum. Acetonitrile: Buffer: Sulfuric Acid (45:55:0.3 v/v/v) was the mobile phase at flow rate 1.0 mL min-1 using a Hibar® Lichrosorb® C18 column and monitored at wavelength of 230nm. The averages of absolute and relative recoveries were found to be 99.3%, 99.5%, 99.8% and 98.7% with correlation coefficient of 0.9977, 0.9998, 0.9984, and 0.9997 for cetirizine HCl, paracetamol, methylparaben and Propylparaben respectively. The limit of quantification and limit of detection were in range of 0.3 to 2.7 ng mL-1 and 0.1 to 0.8 ng mL-1 respectively. Under stress conditions of acidic, basic, oxidative, and thermal degradation, maximum degradation was observed in basic and oxidative stress where a significant impact was observed while all drugs were found almost stable in the other conditions. The developed method was validated in accordance with ICH and AOAC guidelines. The proposed method was successfully applied to quantify amount of paracetamol, cetirizine HCl and two most common microbial preservatives in bulk, dosage form and physiological fluid. PMID:27651840

  1. Validated stability-indicating HPLC method for the determination of pridinol mesylate. Kinetics study of its degradation in acid medium.

    PubMed

    Bianchini, Romina M; Castellano, Patricia M; Kaufman, Teodoro S

    2008-12-01

    The stability of pridinol mesylate (PRI) was investigated under different stress conditions, including hydrolytic, oxidative, photolytic and thermal, as recommended by the ICH guidelines. Relevant degradation was found to take place under acidic (0.1N HCl) and photolytic (visible and long-wavelength UV-light) conditions, both yielding the product resulting from water elimination (ELI), while submission to an oxidizing environment gave the N-oxidation derivative (NOX). The standards of these degradation products were synthesized and characterized by IR, (1)H and (13)C NMR spectroscopy. A simple, sensitive and specific HPLC method was developed for the quantification of PRI, ELI and NOX in bulk drug, and the conditions were optimized by means of a statistical design strategy. The separation employs a C(18) column and a 51:9:40 (v/v/v) mixture of MeOH, 2-propanol and potassium phosphate solution (50mM, pH 6.0), as mobile phase, delivered at 1.0 ml min(-1); the analytes were detected and quantified at 220 nm. The method was validated, demonstrating to be accurate and precise (repeatability and intermediate precision levels) within the corresponding linear ranges of PRI (0.1-1.5 mg ml(-1); r=0.9983, n=18) and both impurities (0.1-1.3% relative to PRI, r=0.9996 and 0.9995 for ELI and NOX, respectively, n=18). Robustness against small modifications of pH and percentage of the aqueous mobile phase was ascertained and the limits of quantification of the analytes were also determined (0.4 and 0.5 microg ml(-1); 0.04% and 0.05% relative to PRI for ELI and NOX, respectively). Peak purity indices (>0.9997), obtained with the aid of diode-array detection, and satisfactory resolution (R(s)>2.0) between PRI and its impurities established the specificity of the determination, all these results proving the stability-indicating capability of the method. The kinetics of the degradation of PRI in acid medium was also studied, determining that this is a first-order process with regards to drug concentration, with an activation energy of 25.5 Kcal mol(-1) and a t(1/2)=10,830 h, in 0.1N HCl at 38 degrees C.

  2. Simultaneous Determination of Potassium Sorbate, Sodium Benzoate, Quinoline Yellow and Sunset Yellow in Lemonades and Lemon Sauces by HPLC Using Experimental Design.

    PubMed

    Dinç Zor, Şule; Aşçı, Bürge; Aksu Dönmez, Özlem; Yıldırım Küçükkaraca, Dilek

    2016-07-01

    In this study, development and validation of a HPLC method was described for simultaneous determination of potassium sorbate, sodium benzoate, quinoline yellow and sunset yellow. A Box-Behnken design using three variables at three levels was employed to determine the optimum conditions of chromatographic separation: pH of mobile phase, 6.0-7.0; flow rate, 0.8-1.2 mL min(-1) and the ratio of mobile phase composed of a 0.025 M sodium acetate/acetic acid buffer, 80-90%. Resolution was chosen as a response. The optimized method was validated for linearity, the limits of detection and quantification, accuracy, precision and stability. All the validation parameters were within the acceptance range. The applicability of the developed method to the determination of these food additives in commercial lemonade and lemon sauce samples was successfully demonstrated. © The Author 2016. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.

  3. Optimization and Validation of a Sensitive Method for HPLC-PDA Simultaneous Determination of Torasemide and Spironolactone in Human Plasma using Central Composite Design.

    PubMed

    Subramanian, Venkatesan; Nagappan, Kannappan; Sandeep Mannemala, Sai

    2015-01-01

    A sensitive, accurate, precise and rapid HPLC-PDA method was developed and validated for the simultaneous determination of torasemide and spironolactone in human plasma using Design of experiments. Central composite design was used to optimize the method using content of acetonitrile, concentration of buffer and pH of mobile phase as independent variables, while the retention factor of spironolactone, resolution between torasemide and phenobarbitone; and retention time of phenobarbitone were chosen as dependent variables. The chromatographic separation was achieved on Phenomenex C(18) column and the mobile phase comprising 20 mM potassium dihydrogen ortho phosphate buffer (pH-3.2) and acetonitrile in 82.5:17.5 v/v pumped at a flow rate of 1.0 mL min(-1). The method was validated according to USFDA guidelines in terms of selectivity, linearity, accuracy, precision, recovery and stability. The limit of quantitation values were 80 and 50 ng mL(-1) for torasemide and spironolactone respectively. Furthermore, the sensitivity and simplicity of the method suggests the validity of method for routine clinical studies.

  4. Application of quality by design concept to develop a dual gradient elution stability-indicating method for cloxacillin forced degradation studies using combined mixture-process variable models.

    PubMed

    Zhang, Xia; Hu, Changqin

    2017-09-08

    Penicillins are typical of complex ionic samples which likely contain large number of degradation-related impurities (DRIs) with different polarities and charge properties. It is often a challenge to develop selective and robust high performance liquid chromatography (HPLC) methods for the efficient separation of all DRIs. In this study, an analytical quality by design (AQbD) approach was proposed for stability-indicating method development of cloxacillin. The structures, retention and UV characteristics rules of penicillins and their impurities were summarized and served as useful prior knowledge. Through quality risk assessment and screen design, 3 critical process parameters (CPPs) were defined, including 2 mixture variables (MVs) and 1 process variable (PV). A combined mixture-process variable (MPV) design was conducted to evaluate the 3 CPPs simultaneously and a response surface methodology (RSM) was used to achieve the optimal experiment parameters. A dual gradient elution was performed to change buffer pH, mobile-phase type and strength simultaneously. The design spaces (DSs) was evaluated using Monte Carlo simulation to give their possibility of meeting the specifications of CQAs. A Plackett-Burman design was performed to test the robustness around the working points and to decide the normal operating ranges (NORs). Finally, validation was performed following International Conference on Harmonisation (ICH) guidelines. To our knowledge, this is the first study of using MPV design and dual gradient elution to develop HPLC methods and improve separations for complex ionic samples. Copyright © 2017 Elsevier B.V. All rights reserved.

  5. Stability indicating HPLC-UV method for detection of curcumin in Curcuma longa extract and emulsion formulation.

    PubMed

    Syed, Haroon Khalid; Liew, Kai Bin; Loh, Gabriel Onn Kit; Peh, Kok Khiang

    2015-03-01

    A stability-indicating HPLC-UV method for the determination of curcumin in Curcuma longa extract and emulsion was developed. The system suitability parameters, theoretical plates (N), tailing factor (T), capacity factor (K'), height equivalent of a theoretical plate (H) and resolution (Rs) were calculated. Stress degradation studies (acid, base, oxidation, heat and UV light) of curcumin were performed in emulsion. It was found that N>6500, T<1.1, K' was 2.68-3.75, HETP about 37 and Rs was 1.8. The method was linear from 2 to 200 μg/mL with a correlation coefficient of 0.9998. The intra-day precision and accuracy for curcumin were ⩽0.87% and ⩽2.0%, while the inter-day precision and accuracy values were ⩽2.1% and ⩽-1.92. Curcumin degraded in emulsion under acid, alkali and UV light. In conclusion, the stability-indicating method could be employed to determine curcumin in bulk and emulsions. Copyright © 2014 Elsevier Ltd. All rights reserved.

  6. Identification and Structure Elucidation of Forced Degradation Products of the Novel Propionic acid Derivative Loxoprofen: Development of Stability-Indicating Chromatographic Methods Validated as per ICH Guidelines.

    PubMed

    Eissa, Maya S; Abd El-Sattar, Osama I

    2017-04-01

    Loxoprofen sodium (LOX) is a recently developed novel propionic acid derivative. Owing to its instability under both hydrolytic and oxidative conditions, the development of simple, rapid and sensitive methods for its determination in the presence of its possible forced degradation products becomes essential. Two simple chromatographic methods, high-performance thin layer chromatography (HPTLC) and high-performance liquid chromatography (HPLC), were developed associated with ultraviolet (UV) detection. In HPTLC-densitometric method, the separation of LOX from its degradation products was achieved using silica gel F254 plates and toluene:acetone:acetic acid (1.8:1.0:0.1, v/v/v) as the developing system followed by densitometric scanning at 220 nm. In the HPLC-UV method, the separation was performed using isocratic elution system with acetonitrile: 0.15% triethylamine (pH 2.2) (50:50, v/v) on C18 analytical column. The flow rate was optimized at 1.0 mL·min-1 and UV detection was achieved at 220 nm. Validation was performed in accordance with the International Conference on Harmonization guidelines and the method was perfectly applied for determination of LOX in its pharmaceutical preparation. The results obtained were statistically compared to those obtained after application of the official HPLC method, where no significant difference was found incompliance with precision and accuracy. Identification and characterization of the possible hydrolytic degradation product under alkaline conditions and that produced during oxidative degradation using hydrogen peroxide were structurally elucidated using infrared and mass spectrometry analyses. © The Author 2016. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.

  7. A Stability-Indicating HPLC Method for the Determination of Fingolimod in Pharmaceutical Dosage Forms.

    PubMed

    Souri, Effat; Zargarpoor, Mohammad; Mottaghi, Siavash; Ahmadkhaniha, Reza; Kebriaeezadeh, Abbas

    2015-01-01

    Fingolimod is an immunosuppressive agent which is used for the prophylaxis of organ transplantation rejection or multiple sclerosis treatment. In this study, systematic forced degradation studies on fingolimod bulk powder were performed to develop a stability-indicating HPLC method. Separation of fingolimod and its degradation products was achieved on a Nova-Pak C8 column. The mobile phase was a mixture of potassium dihydrogenphosphate 50 mM (pH 3.0) and acetonitrile (45:55, v/v) at a flow rate of 1 ml/min. The proposed method was linear in the range of 0.125-20 μg mL(-1). The within-day and between-day coefficients of variation were in the range of 0.6-1.2%. The developed method was successfully applied for the determination of the fingolimod amount in pharmaceutical dosage forms.

  8. Stability indicating RP-HPLC method development and validation for the simultaneous determination of aminexil and minoxidil in pharmaceutical dosage form.

    PubMed

    Siddiraju, S; Sahithi, M

    2015-03-01

    The objective of the present work is to develop stability indicating high-performance liquid chromatographic method for the simultaneous determination of aminexil and minoxidil in pharmaceutical dosage form. The chromatographic separation was achieved with BDS Hypersil C18 column (250 mm×4.6 mm×5 μ) as stationary phase and phosphate buffer and acetonitrile (78:22) as mobile phase. The method was employed by using a flow rate of 1.1 mL/min kept at 30°C. The detection wavelength was kept at 238 nm by using photo-diode array detector. The retention times of the aminexil and minoxidil were found to be 2.3 min and 3.9 min, respectively. The method developed was validated in accordance with ICH guidelines with respect to the stability indicating capacity of the method including system suitability, accuracy, precision, linearity, range, limit of detection, limit of quantification and robustness. The linearity responses of aminexil and minoxidil were found to be in the concentration ranges of 18.75-112.5 μg/mL and 25-150 μg/mL, respectively. The LOD and LOQ values for aminexil were found to be 0.31 and 0.92 μg/mL and minoxidil were found to be 0.03 and 0.10 μg/mL respectively. The percentage recoveries for both the drugs were found in the range of 98-101%. This method is accurate, precise and sensitive; hence, it can be employed for routine quality control of aminexil and minoxidil in pharmaceutical industries and drug testing laboratories. Copyright © 2014 Elsevier Masson SAS. All rights reserved.

  9. Physicochemical stability and biological activity of Withania somnifera extract under real-time and accelerated storage conditions.

    PubMed

    Patil, Dada; Gautam, Manish; Jadhav, Umesh; Mishra, Sanjay; Karupothula, Suresh; Gairola, Sunil; Jadhav, Suresh; Patwardhan, Bhushan

    2010-03-01

    Stability testing at preformulation stages is a crucial part of drug development. We studied physicochemical stability and biological activity of Withania somnifera (ashwagandha) dried root aqueous extract during six months real-time and under accelerated storage conditions. The characteristic constituents of ashwagandha roots include withanolides such as withaferin A and withanolide A. We modified and validated the HPLC-DAD method for quantitative measurement of withanolides and fingerprint analysis. The results suggest a significant decline in withaferin A and withanolide A content under real and accelerated conditions. The HPLC fingerprint analysis showed significant changes in some peaks during real and accelerated storage (> 20 %). We also observed incidences of clump formation and moisture sensitivity (> 10 %) under real-time and accelerated storage conditions. These changes were concurrent with a significant decline in immunomodulatory activity (p < 0.01) during the third month of the accelerated storage. Thus, adequate control of temperature and humidity is important for WSE containing formulations. This study may help in proposing suitable guidance for storage conditions and shelf life of ashwagandha formulations. (c) Georg Thieme Verlag KG Stuttgart . New York.

  10. Near-Infrared Spectroscopy Assay of Key Quality-Indicative Ingredients of Tongkang Tablets.

    PubMed

    Pan, Wenjie; Ma, Jinfang; Xiao, Xue; Huang, Zhengwei; Zhou, Huanbin; Ge, Fahuan; Pan, Xin

    2017-04-01

    The objective of this paper is to develop an easy and fast near-infrared spectroscopy (NIRS) assay for the four key quality-indicative active ingredients of Tongkang tablets by comparing the true content of the active ingredients measured by high performance liquid chromatography (HPLC) and the NIRS data. The HPLC values for the active ingredients content of Cimicifuga glycoside, calycosin glucoside, 5-O-methylvisamminol and hesperidin in Tongkang tablets were set as reference values. The NIRS raw spectra of Tongkang tablets were processed using first-order convolution method. The iterative optimization method was chosen to optimize the band for Cimicifuga glycoside and 5-O-methylvisamminol, and correlation coefficient method was used to determine the optimal band of calycosin glucoside and hesperidin. A near-infrared quantitative calibration model was established for each quality-indicative ingredient by partial least-squares method on the basis of the contents detected by HPLC and the obtained NIRS spectra. The correlation coefficient R 2 values of the four models of Cimicifuga glycoside, calycosin glucoside, 5-O-methylvisamminol and hesperidin were 0.9025, 0.8582, 0.9250, and 0.9325, respectively. It was demonstrated that the accuracy of the validation values was approximately 90% by comparison of the predicted results from NIRS models and the HPLC true values, which suggested that NIRS assay was successfully established and validated. It was expected that the quantitative analysis models of the four indicative ingredients could be used to rapidly perform quality control in industrial production of Tongkang tablets.

  11. Development of a validated HPLC method for the quantitative determination of trelagliptin succinate and its related substances in pharmaceutical dosage forms.

    PubMed

    Luo, Zhiqiang; Chen, Xinjing; Wang, Guopeng; Du, Zhibo; Ma, Xiaoyun; Wang, Hao; Yu, Guohua; Liu, Aoxue; Li, Mengwei; Peng, Wei; Liu, Yang

    2018-01-01

    Trelagliptin succinate is a dipeptidyl peptidase IV (DPP-4) inhibitor which is used as a new long-acting drug for once-weekly treatment of type 2 diabetes mellitus (DM). In the present study, a rapid, sensitive and accurate high-performance liquid chromatography (HPLC) method was developed and validated for separation and determination of trelagliptin succinate and its eight potential process-related impurities. The chromatographic separation was achieved on a Waters Xselect CSH™ C 18 (250mm×4.6mm, 5.0μm) column. The mobile phases comprised of 0.05% trifluoroacetic acid in water as well as acetonitrile containing 0.05% trifluoroacetic acid. The compounds of interest were monitored at 224nm and 275nm. The stability-indicating capability of this method was evaluated by performing stress test studies. Trelagliptin succinate was found to degrade significantly in acid, base, oxidative and thermal stress conditions and only stable in photolytic degradation condition. The degradation products were well resolved from the main peak and its impurities. In addition, the major degradation impurities formed under acid, base, oxidative and thermal stress conditions were characterized by ultra-high-performance liquid chromatography coupled with linear ion trap-Orbitrap tandem mass spectrometry (UHPLC-LTQ-Orbitrap). The method was validated to fulfill International Conference on Harmonisation (ICH) requirements and this validation included specificity, linearity, limit of detection (LOD), limit of quantification (LOQ), accuracy, precision and robustness. The developed method in this study could be applied for routine quality control analysis of trelagliptin succinate tablets, since there is no official monograph. Copyright © 2017 Elsevier B.V. All rights reserved.

  12. Development and validation of polar RP-HPLC method for screening for ectoine high-yield strains in marine bacteria with green chemistry.

    PubMed

    Chen, Jun; Chen, Jianwei; Wang, Sijia; Zhou, Guangmin; Chen, Danqing; Zhang, Huawei; Wang, Hong

    2018-04-02

    A novel, green, rapid, and precise polar RP-HPLC method has been successfully developed and screened for ectoine high-yield strain in marine bacteria. Ectoine is a polar and extremely useful solute which allows microorganisms to survive in extreme environmental salinity. This paper describes a polar-HPLC method employed polar RP-C18 (5 μm, 250 × 4.6 mm) using pure water as the mobile phase and a column temperature of 30 °C, coupled with a flow rate at 1.0 mL/min and detected under a UV detector at wavelength of 210 nm. Our method validation demonstrates excellent linearity (R 2  = 0.9993), accuracy (100.55%), and a limit of detection LOQ and LOD of 0.372 and 0.123 μgmL -1 , respectively. These results clearly indicate that the developed polar RP-HPLC method for the separation and determination of ectoine is superior to earlier protocols.

  13. Stability-Indicating HPLC Determination of Gemcitabine in Pharmaceutical Formulations

    PubMed Central

    Singh, Rahul; Shakya, Ashok K.; Naik, Rajashri; Shalan, Naeem

    2015-01-01

    A simple, sensitive, inexpensive, and rapid stability indicating high performance liquid chromatographic method has been developed for determination of gemcitabine in injectable dosage forms using theophylline as internal standard. Chromatographic separation was achieved on a Phenomenex Luna C-18 column (250 mm × 4.6 mm; 5μ) with a mobile phase consisting of 90% water and 10% acetonitrile (pH 7.00 ± 0.05). The signals of gemcitabine and theophylline were recorded at 275 nm. Calibration curves were linear in the concentration range of 0.5–50 μg/mL. The correlation coefficient was 0.999 or higher. The limit of detection and limit of quantitation were 0.1498 and 0.4541 μg/mL, respectively. The inter- and intraday precision were less than 2%. Accuracy of the method ranged from 100.2% to 100.4%. Stability studies indicate that the drug was stable to sunlight and UV light. The drug gives 6 different hydrolytic products under alkaline stress and 3 in acidic condition. Aqueous and oxidative stress conditions also degrade the drug. Degradation was higher in the alkaline condition compared to other stress conditions. The robustness of the methods was evaluated using design of experiments. Validation reveals that the proposed method is specific, accurate, precise, reliable, robust, reproducible, and suitable for the quantitative analysis. PMID:25838825

  14. Stability-indicating RP-HPLC Method for the Simultaneous Determination of Sitagliptin and Simvastatin in Tablets

    PubMed Central

    Ramalingam, P.; Bhaskar, V. Udaya; Reddy, Y. Padmanabha; Kumar, K. Vinod

    2014-01-01

    A new stability-indicating high-performance liquid chromatographic method for simultaneous analysis of sitagliptin and simvastatin in pharmaceutical dosage form was developed and validated. The mobile phase consisted of methanol and water (70:30, v/v) with 0.2 % of n-heptane sulfonic acid adjusted to pH 3.0 with ortho phosphoric acid was used. Retentions of sitagliptin and simvastatin were 4.3 min and 30.4 min, respectively with a flow rate of 1 ml/min on C8 (Qualisil BDS, 250×4.6 mm, 5 μ). Eluents were detected at 253 nm using photodiode diode array detector. The linear regression analysis data for the linearity plot showed correlation coefficient values of 0.9998 and 0.9993 for sitagliptin and simvastatin, with respective concentration ranges of 20-150 μg/ml and 8-60 μg/ml. The relative standard deviation for inter-day precision was lower than 2.0%. The assay of sitagliptin and simvastatin was determined in tablet dosage form was found to be within limits. Both drugs were subjected to a variety of stress conditions such as acidic, basic, oxidation, photolytic, neutral and thermal stress in order to achieve adequate degradation. Results revealed that considerable degradation was found in all stress conditions except oxidative degradations. The method has proven specificity for stability indicating assay method. PMID:25425754

  15. Quantitative Determination of α-Arbutin, β-Arbutin, Kojic Acid, Nicotinamide, Hydroquinone, Resorcinol, 4-Methoxyphenol, 4-Ethoxyphenol, and Ascorbic Acid from Skin Whitening Products by HPLC-UV.

    PubMed

    Wang, Yan-Hong; Avonto, Cristina; Avula, Bharathi; Wang, Mei; Rua, Diego; Khan, Ikhlas A

    2015-01-01

    An HPLC-UV method was developed for the quantitative analysis of nine skin whitening agents in a single injection. These compounds are α-arbutin, β-arbutin, kojic acid, nicotinamide, resorcinol, ascorbic acid, hydroquinone, 4-methoxyphenol, and 4-ethoxyphenol. The separation was achieved on a reversed-phase C18 column within 30 min. The mobile phase was composed of water and methanol, both containing 0.1% acetic acid (v/v). The stability of the analytes was evaluated at different pH values between 2.3 and 7.6, and the extraction procedure was validated for different types of skin whitening product matrixes, which included two creams, a soap bar, and a capsule. The best solvent system for sample preparation was 20 mM NaH2PO4 containing 10% methanol at pH 2.3. The analytical method was validated for accuracy, precision, LOD, and LOQ. The developed HPLC-UV method was applied for the quantitation of the nine analytes in 59 skin whitening products including creams, lotions, sera, foams, gels, mask sheets, soap bars, tablets, and capsules.

  16. Therapeutic drug monitoring of beta-lactam antibiotics - Influence of sample stability on the analysis of piperacillin, meropenem, ceftazidime and flucloxacillin by HPLC-UV.

    PubMed

    Pinder, Nadine; Brenner, Thorsten; Swoboda, Stefanie; Weigand, Markus A; Hoppe-Tichy, Torsten

    2017-09-05

    Therapeutic drug monitoring (TDM) is a useful tool to optimize antibiotic therapy. Increasing interest in alternative dosing strategies of beta-lactam antibiotics, e.g. continuous or prolonged infusion, require a feasible analytical method for quantification of these antimicrobial agents. However, pre-analytical issues including sample handling and stability are to be considered to provide valuable analytical results. For the simultaneous determination of piperacillin, meropenem, ceftazidime and flucloxacillin, a high performance liquid chromatography (HPLC) method including protein precipitation was established utilizing ertapenem as internal standard. Long-term stability of stock solutions and plasma samples were monitored. Furthermore, whole blood stability of the analytes in heparinized blood tubes was investigated comparing storage under ambient conditions and 2-8°C. A calibration range of 5-200μg/ml (piperacillin, ceftazidime, flucloxacillin) and 2-200μg/ml (meropenem) was linear with r 2 >0.999, precision and inaccuracy were <9% and <11%, respectively. The successfully validated HPLC assay was applied to clinical samples and stability investigations. At -80°C, plasma samples were stable for 9 months (piperacillin, meropenem) or 13 months (ceftazidime, flucloxacillin). Concentrations of the four beta-lactam antibiotics in whole blood tubes were found to remain within specifications for 8h when stored at 2-8°C but not at room temperature. The presented method is a rapid and simple option for routine TDM of piperacillin, meropenem, ceftazidime and flucloxacillin. Whereas long-term storage of beta-lactam samples at -80°C is possible for at least 9 months, whole blood tubes are recommended to be kept refrigerated until analysis. Copyright © 2017 Elsevier B.V. All rights reserved.

  17. Fingerprint chromatogram analysis of Pseudostellaria heterophylla (Miq.) Pax root by high performance liquid chromatography.

    PubMed

    Han, Chao; Chen, Junhui; Chen, Bo; Lee, Frank Sen-Chun; Wang, Xiaoru

    2006-09-01

    A simple and reliable high performance liquid chromatographic (HPLC) method has been developed and validated for the fingerprinting of extracts from the root of Pseudostellaria heterophylla (Miq.) Pax. HPLC with gradient elution was performed on an authentic reference standard of powdered P. heterophylla (Miq.) Pax root and 11 plant samples of the root were collected from different geographic locations. The HPLC chromatograms have been standardized through the selection and identification of reference peaks and the normalization of retention times and peak intensities of all the common peaks. The standardized HPLC fingerprints show high stability and reproducibility, and thus can be used effectively for the screening analysis or quality assessment of the root or its derived products. Similarity index calculations based on cosine angle values or correlation methods have been performed on the HPLC fingerprints. As a group, the fingerprints of the P. heterophylla (Miq.) Pax samples studied are highly correlated with closely similar fingerprints. Within the group, the samples can be further divided into subgroups based on hierarchical clustering analysis (HCA). Sample grouping based on HCA coincides nicely with those based on the geographical origins of the samples. The HPLC fingerprinting techniques thus have high potential in authentication or source-tracing types of applications.

  18. Evaluation of a novel semi-automated HPLC procedure for whole blood cyclosporin A confirms equivalence to adjusted monoclonal values from Abbott TDx.

    PubMed

    Roberts, Norman B; Dutton, John; Higgins, Gerald; Allars, Lesley

    2005-01-01

    The problem in the measurement of cyclosporin (CyA) is that the widely used immuno-based assays suffer from interference by metabolites present in unpredictable excess. To resolve this, the consensus view has been to develop more specific and robust procedures for the measurement of CyA alone in order to give values similar to those obtained by HPLC. We developed an alternative strategy based on Abbott poly- and monoclonal assays to derive an adjusted monoclonal value as an equivalent measurement to HPLC. We have now evaluated a recently developed semi-automated HPLC procedure and used it to test the validity of the adjusted monoclonal value. The automated HPLC procedure with online clean-up was optimised for the separation of CyA and internal standard CyD. The assay was simple to use, precise and gave good recovery of cyclosporin from whole blood. Comparisons with the more specific immunoassays Abbott AxSym and EMIT showed close agreement, whereas Abbott monoclonal values indicated up to 20% positive bias. In contrast, the adjusted monoclonal values gave good agreement with HPLC. Data obtained from HPLC linked to tandem mass spectrometry (MS) indicated closer agreement with Abbott monoclonal values than expected, suggesting some positive bias with MS. The benefit of using an adjusted monoclonal value is that a result equivalent to HPLC is obtained, as well as an indication of the concentration of metabolites from the Abbott polyclonal measurement.

  19. Measurement of HbA1c in Gingival Crevicular Blood Using a High Pressure Liquid Chromatography Procedure

    PubMed Central

    Pesce, Michael A.; Strauss, Shiela M.; Rosedale, Mary; Netterwald, Jane; Wang, Hangli

    2016-01-01

    Objectives To validate an ion exchange high-pressure liquid chromatography (HPLC) method for measuring glycated hemoglobin (HbA1c) in gingival crevicular blood (GCB) spotted on filter paper, for use in screening dental patients for diabetes. Methods We collected the GCB specimens for this study from the oral cavities of patients during dental visits, using rigorous strategies to obtain GCB that was as free of debris as possible. The analytical performance of the HPLC method was determined by measuring the precision, linearity, carryover, stability of HbA1c in GCB, and correlation of HbA1c results in GCB specimens with finger-stick blood (FSB) specimens spotted on filter paper. Results The coefficients of variation (CVs) for the inter- and intrarun precision of the method were less than 2.0%. Linearity ranged between 4.2% and 12.4%; carryover was less than 2.0%, and the stability of the specimen was 6 days at 4°C and as many as 14 days at −70°C. Linear regression analysis comparing the HbA1c results in GCB with FSB yielded a correlation coefficient of 0.993, a slope of 0.981, and an intercept of 0.13. The Bland-Altman plot showed no difference in the HbA1c results from the GCB and FSB specimens at normal, prediabetes, and diabetes HbA1c levels. Conclusion We validated an HPLC method for measuring HbA1c in GCB; this method can be used to screen dental patients for diabetes. PMID:26489673

  20. Development of new method for simultaneous analysis of piracetam and levetiracetam in pharmaceuticals and biological fluids: application in stability studies.

    PubMed

    Siddiqui, Farhan Ahmed; Sher, Nawab; Shafi, Nighat; Wafa Sial, Alisha; Ahmad, Mansoor; Mehjebeen; Naseem, Huma

    2014-01-01

    RP-HPLC ultraviolet detection simultaneous quantification of piracetam and levetiracetam has been developed and validated. The chromatography was obtained on a Nucleosil C18 column of 25 cm×0.46 cm, 10 μm, dimension. The mobile phase was a (70:30 v/v) mixture of 0.1 g/L of triethylamine and acetonitrile. Smooth flow of mobile phase at 1 mL/min was set and 205 nm wavelength was selected. Results were evaluated through statistical parameters which qualify the method reproducibility and selectivity for the quantification of piracetam, levetiracetam, and their impurities hence proving stability-indicating properties. The proposed method is significantly important, permitting the separation of the main constituent piracetam from levetiracetam. Linear behavior was observed between 20 ng/mL and 10,000 ng/mL for both drugs. The proposed method was checked in bulk drugs, dosage formulations, physiological condition, and clinical investigations and excellent outcome was witnessed.

  1. Development and validation of a stability-indicating RP-HPLC-FLD method for determination of 5-[(4-chlorophenoxy) methyl]-1, 3, 4-oxadiazole-2-thiol; A novel drug candidate.

    PubMed

    Shehzadi, Naureen; Hussain, Khalid; Islam, Muhammad; Bukhari, Nadeem Irfan; Asif, Noman; Khan, Muhammad Tanveer; Salman, Muhammad; Qamar, Shaista; Parveen, Sajida; Zahid, Fakhra; Shah, Arshad Ali; Bilal, Abida; Abbasi, Muhammad Athar; Siddiqui, Sabahat Zahra; Rehman, Azizur

    2018-03-01

    The present study describes the development and validation of a simple high performance liquid chromatographic method for the determination of a novel drug candidate, 5-[(4-chlorophenoxy) methyl]-1, 3, 4-oxadiazole-2-thiol. The stability-indicating capacity of the method was evaluated by subjecting the compound's solution to hydrolytic, oxidative, photolytic, transition metal- and thermal- stress. The chromatographic separation was achieved over a C18 column (Promosil, 5 µm, 4.60 × 250 mm), maintained at 25°C, using an isocratic mobile phase comprising a mixture of acetonitrile and acidified water of pH 2.67 (1:1, v/v), at a flow rate of 1.00 mL/min and detection using a fluorescent light detector (excitation at 250 nm and emission at 410 nm). The Beer's law was followed over the concentration range 2.50-50.00 μg/ml. The recovery (98.56-100.19%, SD <5%), intraday accuracy and precision (97.31-100.81%, RSD <5%), inter-day accuracy and precision (97.50-100.75%, RSD <5%) and intermediate accuracy and precision (98.10-99.91%, RSD <5%) indicated that the method was reliable, repeatable, reproducible and rugged. The resolution and selectivity factors of the compound's peak from the nearest resolving peak, particularly in case of dry heat and copper metal stress, were found to be greater than 2 and 1, respectively, which indicated specificity and selectivity. The compound was extensively decomposed in alkaline-hydrolytic, oxidative, metal- and dry heat- stress. However, the compound in acidic and neutral conditions was resistant to photolysis. The results of the present study indicate that the developed method is specific, selective, sensitive and suitable, hence, may be used for quality control, stability testing and preformulation studies.

  2. Chemical stability of oseltamivir in oral solutions.

    PubMed

    Albert, K; Bockshorn, J

    2007-09-01

    The stability of oseltamivir in oral aqueous solutions containing the preservative sodium benzoate was studied by a stability indicating HPLC-method. The separation was achieved on a RP-18 ec column using a gradient of mobile phase A (aqueous solution of 50 mM ammonium acetate) and mobile phase B (60% (v/v) acetonitrile/40% (v/v) mobile phase A). The assay was subsequently validated according to the ICH guideline Q2(R1). The extemporaneously prepared "Oseltamivir Oral Solution 15 mg/ml for Adults or for Children" (NRF 31.2.) according to the German National Formulary ("Neues Rezeptur-Formularium") was stable for 84 days if stored under refrigeration. After storage at 25 degrees C the content of oseltamivir decreased to 98.4%. Considering the toxicological limit of 0.5% of the 5-acetylamino derivative (the so-called isomer I) the solution is stable for 46 days. Oseltamivir was less stable in a solution prepared with potable water instead of purified water. Due to an increasing pH the stability of this solution decreased to 14 days. Furthermore a white precipitate of mainly calcium phosphate was observed. The addition of 0.1% anhydrous citric acid avoided these problems and improved the stability of the solution prepared with potable water to 63 days. Sodium benzoate was stable in all oral solutions tested.

  3. Development and validation of a stability-indicating HPLC-UV method for the determination of triamcinolone acetonide and its degradation products in an ointment formulation.

    PubMed

    van Heugten, A J P; de Boer, W; de Vries, W S; Markesteijn, C M A; Vromans, H

    2018-02-05

    A stability indicating high performance liquid chromatography method has been developed for the determination of triamcinolone acetonide (TCA) and its main degradation products in ointment formulations. The method, based on extensive stress testing using metal salts, azobisisobutyronitrile, acid, base and peroxide, showed that TCA undergoes oxidative degradation. All degradation products were identified using HPLC mass spectrometry. Separation and quantification was achieved using an Altima C18 RP18 HP column (250×4.6mm 2 , with 5μm particles) using a mobile phase consisting of acetonitrile and water buffered at pH 7 using 10mM phosphate buffer. A gradient mode was operated at a flow rate of 1.5ml/min and detection was at 241nm. The method showed linearity for TCA and Impurity C in 0.02-125% of the workload, both square roots of the correlation coefficients were larger than 0.9999. Repeatability and intermediate precision were performed by six consecutive injections of both 1.25% and 125% of the work load for both TCA and Impurity C divided equally over two days. RSD were 0.6% and 0.7% for TCA and 0.5% and 0.1% for Impurity C respectively. Accuracy was determined as well, the average recoveries were 99.5% (±0.1%, n=3) for TCA and 96.9% (±1.3%, n=3) for impurity C respectively from spiked ointment samples. The robustness was also evaluated by variations of column (old vs new), mobile phase pH and filter retention. The applicability of the method was evaluated by analysis of a commercial ointment formulation. Interestingly, the extensive stress tests were able to predict all degradation products of TCA in a long term stability ointment sample. Copyright © 2017 Elsevier B.V. All rights reserved.

  4. A Stability-Indicating HPLC Method for the Determination of Fingolimod in Pharmaceutical Dosage Forms

    PubMed Central

    Souri, Effat; Zargarpoor, Mohammad; Mottaghi, Siavash; Ahmadkhaniha, Reza; Kebriaeezadeh, Abbas

    2015-01-01

    Fingolimod is an immunosuppressive agent which is used for the prophylaxis of organ transplantation rejection or multiple sclerosis treatment. In this study, systematic forced degradation studies on fingolimod bulk powder were performed to develop a stability-indicating HPLC method. Separation of fingolimod and its degradation products was achieved on a Nova-Pak C8 column. The mobile phase was a mixture of potassium dihydrogenphosphate 50 mM (pH 3.0) and acetonitrile (45:55, v/v) at a flow rate of 1 ml/min. The proposed method was linear in the range of 0.125–20 μg mL−1. The within-day and between-day coefficients of variation were in the range of 0.6–1.2%. The developed method was successfully applied for the determination of the fingolimod amount in pharmaceutical dosage forms. PMID:26839803

  5. Identification, characterization, synthesis and HPLC quantification of new process-related impurities and degradation products in retigabine.

    PubMed

    Douša, Michal; Srbek, Jan; Rádl, Stanislav; Cerný, Josef; Klecán, Ondřej; Havlíček, Jaroslav; Tkadlecová, Marcela; Pekárek, Tomáš; Gibala, Petr; Nováková, Lucie

    2014-06-01

    Two new impurities were described and determined using gradient HPLC method with UV detection in retigabine (RET). Using LC-HRMS, NMR and IR analysis the impurities were identified as RET-dimer I: diethyl {4,4'-diamino-6,6'-bis[(4-fluorobenzyl)amino]biphenyl-3,3'-diyl}biscarbamate and RET-dimer II: ethyl {2-amino-5-[{2-amino-4-[(4-fluorobenzyl) amino] phenyl} (ethoxycarbonyl) amino]-4-[(4-fluorobenzyl)amino] phenyl}carbamate. Reference standards of these impurities were synthesized followed by semipreparative HPLC purification. The mechanism of the formation of these impurities is also discussed. An HPLC method was optimized in order to separate, selectively detect and quantify all process-related impurities and degradation products of RET. The presented method, which was validated in terms of linearity, limit of detection (LOD), limit of quantification (LOQ) and selectivity is very quick (less than 11min including re-equilibration time) and therefore highly suitable for routine analysis of RET related substances as well as stability studies. Copyright © 2014 Elsevier B.V. All rights reserved.

  6. Stability-indicating methods for the determination of piretanide in presence of the alkaline induced degradates.

    PubMed

    Youssef, Nadia F

    2005-10-04

    Stability-indicating high performance liquid chromatography (HPLC), thin-layer chromatography (TLC) and first-derivative of ratio spectra (1DD) methods are developed for the determination of piretanide in presence of its alkaline induced degradates. HPLC method depends on separation of piretanide from its degradates on mu-Bondapak C18 column using methanol:water:acetic acid (70:30:1, v/v/v) as a mobile phase at flow rate 1.0 ml/min and UV detector at 275 nm. TLC densitometic method is based on the difference in Rf-values between the intact drug and its degradates on thin-layer silica gel. Iso-propanol:ammonia 33% (8:2, v/v) was used as a developing mobile phase and the chromatogram was scanned at 275 nm. The derivative of ratio spectra method (1DD) depends on the measurement of the absorbance at 288 nm in the first-derivative of ratio spectra for the determination of the cited drug in the presence of its degradates. Calibration graphs of the three suggested methods are linear in the concentration ranges 0.02-0.3 microg/20 microl, 0.5-10 microg/spot and 5-50 microg/ml, with mean percentage recovery 99.27+/-0.52, 99,17+/-1.01 and 99.65+/-1.01%, respectively. The three proposed methods were successfully applied for the determination of piretanide in bulk powder, laboratory-prepared mixtures and pharmaceutical dosage form with good accuracy and precision. The results were statistically analyzed and compared with those obtained by the official method. Validation of the method was determined with favourable specificity, linearity, precision, and accuracy was assessed by applying the standard addition technique.

  7. Determination of three steroidal saponins from Ophiopogon japonicus (Liliaceae) via high-performance liquid chromatography with mass spectrometry.

    PubMed

    Wang, Yongyi; Xu, Jinzhong; Qu, Haibin

    2013-01-01

    A simple and accurate analytical method was developed for simultaneous quantification of three steroidal saponins in the roots of Ophiopogon japonicus via high-performance liquid chromatography (HPLC) with mass spectrometry (MS) in this study. Separation was performed on a Tigerkin C(18) column and detection was performed by mass spectrometry. A mobile phase consisted of 0.02% formic acid in water (v/v) and 0.02% formic acid in acetonitrile (v/v) was used with a flow rate of 0.5 mL min(-1). The quantitative HPLC-MS method was validated for linearity, precision, repeatability, stability, recovery, limits of detection and quantification. This developed method provides good linearity (r >0.9993), intra- and inter-day precisions (RSD <4.18%), repeatability (RSD <5.05%), stability (RSD <2.08%) and recovery (93.82-102.84%) for three steroidal saponins. It could be considered as a suitable quality control method for O. japonicus.

  8. Validation of RP-HPLC method and stress degradation for the combination of metformin HCl, atorvastatin calcium and glimepiride: application to nanoparticles.

    PubMed

    Gite, Sandip; Patravale, Vandana

    2015-01-01

    A stability-indicating high-performance liquid chromatography (HPLC) procedure was developed for the determination of metformin HCl (MTH), atorvastatin calcium (AC) and glimepiride (GP) in combination and their main degradation products. The separation and quantization were achieved on a 5-µm Qualisil gold, C18 column (4.6 mm × 250 mm). The mobile phase selected was phosphate buffer (pH 2.9)-organic phase in proportion of 70:30. Organic phase consisted of methanol-acetonitrile (90:10) at a flow rate of 1 mL/min and detection of analytes was carried out at 230 nm. The method exhibited good linearity over the range of 10-60 µg/mL for MTH, 2-20 µg/mL for AC and 5-30 µg/mL for GP. Square of the correlation coefficients was found to be >0.999. Various stress degradation studies were carried out in combination as per International Conference of Harmonization (ICH) guidelines for 4 h. The recovery and precision were determined in terms of intraday and interday precisions and expressed as relative standard deviations. These were <1 and <2%, respectively. Finally, the applicability of the method was evaluated in nanoparticle analysis of MTH, AC and GP as well as in stability studies of nanoformulation. © The Author 2015. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.

  9. Pediatric oral solutions with propranolol hydrochloride for extemporaneous compounding: the formulation and stability study.

    PubMed

    Klovrzová, Sylva; Zahálka, Lukáš; Matysová, Ludmila; Horák, Petr; Sklubalová, Zdenka

    2013-02-01

    The aim of this study is to formulate an extemporaneous pediatric oral solution of propranolol hydrochloride (PRO) 2 mg/ml for the therapy of infantile haemangioma or hypertension in a target age group of 1 month to school children and to evaluate its stability. A citric acid solution and/or a citrate-phosphate buffer solution, respectively, were used as the vehicles to achieve pH value of about 3, optimal for the stability of PRO. In order to mask the bitter taste of PRO, simple syrup was used as the sweetener. All solutions were stored in tightly closed brown glass bottles at 5 ± 3 °C and/or 25 ± 3 °C, respectively. The validated HPLC method was used to evaluate the concentration of PRO and a preservative, sodium benzoate, at time intervals of 0-180 days. All preparations were stable at both storage temperatures with pH values in the range of 2.8-3.2. According to pharmacopoeial requirements, the efficacy of sodium benzoate 0.05 % w/v was proved (Ph.Eur., 5.1.3). The preparation formulated with the citrate-phosphate buffer, in our experience, had better palatability than that formulated with the citric acid solution. propranolol hydrochloride pediatric preparation extemporaneous preparation solution stability testing HPLC.

  10. Quantitative determination of a chemically modified hammerhead ribozyme in blood plasma using 96-well solid-phase extraction coupled with high-performance liquid chromatography or capillary gel electrophoresis.

    PubMed

    Bellon, L; Maloney, L; Zinnen, S P; Sandberg, J A; Johnson, K E

    2000-08-01

    Versatile bioanalytical assays to detect chemically stabilized hammerhead ribozyme and putative ribozyme metabolites from plasma are described. The extraction protocols presented are based on serial solid-phase extractions performed on a 96-well plate format and are compatible with either IEX-HPLC or CGE back-end analysis. A validation of both assays confirmed that both the HPLC and the CGE methods possess the required linearity, accuracy, and precision to accurately measure concentrations of hammerhead ribozyme extracted from plasma. These methods should be of general use to detect and quantitate ribozymes from other biological fluids such as serum and urine. Copyright 2000 Academic Press.

  11. First derivative ratio spectrophotometric, HPTLC-densitometric, and HPLC determination of nicergoline in presence of its hydrolysis-induced degradation product.

    PubMed

    Ahmad, Abdel Kader S; Kawy, M Abdel; Nebsen, M

    2002-10-15

    Three methods are presented for the determination of Nicergoline in presence of its hydrolysis-induced degradation product. The first method was based on measurement of the first derivative of ratio spectra amplitude of Nicergoline at 291 nm. The second method was based on separation of Nicergoline from its degradation product followed by densitometric measurement of the spots at 287 nm. The separation was carried out on HPTLC silica gel F(254) plates, using methanol-ethyl acetate-glacial acetic acid (5:7:3, v/v/v) as mobile phase. The third method was based on high performance liquid chromatographic (HPLC) separation and determination of Nicergoline from its degradation product on a reversed phase, nucloesil C(18) column using a mobile phase of methanol-water-glacial acetic acid (80:20:0.1, v/v/v) with UV detection at 280 nm. Chlorpromazine hydrochloride was used as internal standard. Laboratory prepared mixtures containing different percentages of the degradation product were analysed by the proposed methods and satisfactory results were obtained. These methods have been successfully applied to the analysis of Nicergoline in Sermion tablets. The validities of these methods were ascertained by applying standard addition technique, the mean percentage recovery +/- R.S.D.% was found to be 99.47 +/- 0.752, 100.01 +/- 0.940, 99.75 +/- 0.740 for the first derivative of ratio spectra method, the HPTLC method and the HPLC method, respectively. The proposed methods were statistically compared with the manufacturer's HPLC method of analysis of Nicergoline and no significant difference was found with respect to both precision and accuracy. They have the advantage of being stability indicating. Therefore, they can be used for routine analysis of the drug in quality control laboratories. Copyright 2002 Elsevier Science B.V.

  12. In Vitro Evaluation of Eslicarbazepine Delivery via Enteral Feeding Tubes.

    PubMed

    Reindel, Kristin; Zhao, Fang; Hughes, Susan; Dave, Vivek S

    2017-12-01

    Purpose: The feasibility of preparing an eslicarbazepine acetate suspension using Aptiom tablets for administration via enteral feeding tubes was evaluated. Methods: Eslicarbazepine acetate suspension (40 mg/mL) was prepared using Aptiom tablets after optimizing the tablet crushing methods and the vehicle composition. A stability-indicating high-performance liquid chromatography (HPLC) method was developed to monitor the eslicarbazepine stability in the prepared suspension. Three enteric feeding tubes of various composition and dimensions were evaluated for the delivery of the suspensions. The suspension was evaluated for the physical and chemical stability for 48 hours. Results: The reproducibility and consistency of particle size reduction was found to be best with standard mortar/pestle. The viscosity analysis and physical stability studies showed that ORA-Plus:water (50:50 v/v) was optimal for suspending ability and flowability of suspension through the tubes. The developed HPLC method was found to be stability indicating and suitable for the assay of eslicarbazepine acetate in the prepared suspension. The eslicarbazepine concentrations in separately prepared suspensions were within acceptable range (±3%), indicating accuracy and reproducibility of the procedure. The eslicarbazepine concentrations in suspensions before and after delivery through the enteric feeding tubes were within acceptable range (±4%), indicating absence of any physical/chemical interactions of eslicarbazepine with the tubes and a successful delivery of eslicarbazepine dosage via enteric feeding tubes. The stability study results showed that eslicarbazepine concentration in the suspension remained unchanged when stored at room temperature for 48 hours. Conclusion: The study presents a convenient procedure for the preparation of a stable suspension of eslicarbazepine acetate (40 mg/mL) using Aptiom tablets, for administration via enteral feeding tubes.

  13. Quality evaluation of Yin Chen Hao Tang extract based on fingerprint chromatogram and simultaneous determination of five bioactive constituents.

    PubMed

    Wang, Xijun; Lv, Haitao; Sun, Hui; Jiang, Xingang; Wu, Zeming; Sun, Wenjun; Wang, Ping; Liu, Lian; Bi, Kaishun

    2008-01-01

    A completely validated method based on HPLC coupled with photodiode array detector (HPLC-UV) was described for evaluating and controlling quality of Yin Chen Hao Tang extract (YCHTE). First, HPLC-UV fingerprint chromatogram of YCHTE was established for preliminarily elucidating amount and chromatographic trajectory of chemical constituents in YCHTE. Second, for the first time, five mainly bioactive constituents in YCHTE were simultaneously determined based on fingerprint chromatogram for furthermore controlling the quality of YCHTE quantitatively. The developed method was applied to analyze 12 batches of YCHTE samples which consisted of herbal drugs from different places of production, showed acceptable linearity, intraday (RSD <5%), interday precision (RSD <4.80%), and accuracy (RSD <2.80%). As a result, fingerprint chromatogram determined 15 representative general fingerprint peaks, and the fingerprint chromatogram resemblances are all better than 0.9996. The contents of five analytes in different batches of YCHTE samples do not indicate significant difference. So, it is concluded that the developed HPLC-UV method is a more fully validated and complete method for evaluating and controlling the quality of YCHTE.

  14. Investigation of folic acid stability in fortified instant noodles by use of capillary electrophoresis and reversed-phase high performance liquid chromatography.

    PubMed

    Hau Fung Cheung, Rodney; Morrison, Paul D; Small, Darryl M; Marriott, Philip J

    2008-12-05

    A single enzyme treatment with alpha-amylase, prior to the quantification of added folic acid (FA) in fortified instant fried Asian noodles with analysis performed by capillary zone electrophoresis (CZE) and reversed-phase high performance liquid chromatography (RP-HPLC) with UV detection, is described. The method was validated and optimized for capillary electrophoresis (CE) with separation achieved using a 8 mM phosphate-12 mM borate run buffer with 5% MeOH at pH 9.5. FA was well separated from matrix components with nicotinic acid (NA) employed as an internal standard. In a comparative study, separation of FA was performed using HPLC with a mobile phase consisting of 27% MeOH (v/v) in aqueous potassium phosphate buffer (3.5 mM KH(2)PO(4) and 3.2 mM K(2)HPO(4)), pH 8.5, and containing 5 mM tetrabutylammonium dihydrogen phosphate as an ion-pairing agent. For both methods, excellent results were obtained for various analytical parameters including linearity, accuracy and precision. The limit of detection was calculated to be 2.2 mg/L for CE without sample stacking and 0.10 mg/L with high performance liquid chromatography (HPLC). Sample extraction involved homogenization and enzymatic extraction with alpha-amylase. Results indicated that FA was stable during four main stages of instant fried noodle manufacturing (dough crumbs, cut sheets, steaming and frying).

  15. QbD-Based Development and Validation of a Stability-Indicating HPLC Method for Estimating Ketoprofen in Bulk Drug and Proniosomal Vesicular System.

    PubMed

    Yadav, Nand K; Raghuvanshi, Ashish; Sharma, Gajanand; Beg, Sarwar; Katare, Om P; Nanda, Sanju

    2016-03-01

    The current studies entail systematic quality by design (QbD)-based development of simple, precise, cost-effective and stability-indicating high-performance liquid chromatography method for estimation of ketoprofen. Analytical target profile was defined and critical analytical attributes (CAAs) were selected. Chromatographic separation was accomplished with an isocratic, reversed-phase chromatography using C-18 column, pH 6.8, phosphate buffer-methanol (50 : 50v/v) as a mobile phase at a flow rate of 1.0 mL/min and UV detection at 258 nm. Systematic optimization of chromatographic method was performed using central composite design by evaluating theoretical plates and peak tailing as the CAAs. The method was validated as per International Conference on Harmonization guidelines with parameters such as high sensitivity, specificity of the method with linearity ranging between 0.05 and 250 µg/mL, detection limit of 0.025 µg/mL and quantification limit of 0.05 µg/mL. Precision was demonstrated using relative standard deviation of 1.21%. Stress degradation studies performed using acid, base, peroxide, thermal and photolytic methods helped in identifying the degradation products in the proniosome delivery systems. The results successfully demonstrated the utility of QbD for optimizing the chromatographic conditions for developing highly sensitive liquid chromatographic method for ketoprofen. © The Author 2015. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.

  16. Simultaneous determination and stability studies of linezolid, meropenem and vancomycin in bacterial growth medium by high-performance liquid chromatography.

    PubMed

    Wicha, Sebastian G; Kloft, Charlotte

    2016-08-15

    For pharmacokinetic/pharmacodynamic (PK/PD) assessment of antibiotics combinations in in vitro infection models, accurate and precise quantification of drug concentrations in bacterial growth medium is crucial for derivation of valid PK/PD relationships. We aimed to (i) develop a high-performance liquid chromatography (HPLC) assay to simultaneously quantify linezolid (LZD), vancomycin (VAN) and meropenem (MER), as typical components of broad-spectrum antibiotic combination therapy, in bacterial growth medium cation-adjusted Mueller-Hinton broth (CaMHB) and (ii) determine the stability profiles of LZD, VAN and MER under conditions in in vitro infection models. To separate sample matrix components, the final method comprised the pretreatment of 100μL sample with 400μL methanol, the evaporation of supernatant and its reconstitution in water. A low sample volume of 2μL processed sample was injected onto an Accucore C-18 column (2.6μm, 100×2.1mm) coupled to a Dionex Ultimate 3000 HPLC+ system. UV detection at 251, 240 and 302nm allowed quantification limits of 0.5, 2 and 0.5μg/mL for LZD, VAN and MER, respectively. The assay was successfully validated according to the relevant EMA guideline. The rapid method (14min) was successfully applied to quantify significant degradation of LZD, VAN and MER in in vitro infection models: LZD was stable, VAN degraded to 90.6% and MER to 62.9% within 24h compared to t=0 in CaMHB at 37°C, which should be considered when deriving PK/PD relationships in in vitro infection models. Inclusion of further antibiotics into the flexible gradient-based HPLC assay seems promising. Copyright © 2016 Elsevier B.V. All rights reserved.

  17. Measurement of HbA1c in Gingival Crevicular Blood Using a High-Pressure Liquid Chromatography Procedure.

    PubMed

    Pesce, Michael A; Strauss, Shiela M; Rosedale, Mary; Netterwald, Jane; Wang, Hangli

    2015-01-01

    To validate an ion exchange high-pressure liquid chromatography (HPLC) method for measuring glycated hemoglobin (HbA1c) in gingival crevicular blood (GCB) spotted on filter paper, for use in screening dental patients for diabetes. We collected the GCB specimens for this study from the oral cavities of patients during dental visits, using rigorous strategies to obtain GCB that was as free of debris as possible. The analytical performance of the HPLC method was determined by measuring the precision, linearity, carryover, stability of HbA1c in GCB, and correlation of HbA1c results in GCB specimens with finger-stick blood (FSB) specimens spotted on filter paper. The coefficients of variation (CVs) for the inter- and intrarun precision of the method were less than 2.0%. Linearity ranged between 4.2% and 12.4%; carryover was less than 2.0%, and the stability of the specimen was 6 days at 4°C and as many as 14 days at -70°C. Linear regression analysis comparing the HbA1c results in GCB with FSB yielded a correlation coefficient of 0.993, a slope of 0.981, and an intercept of 0.13. The Bland-Altman plot showed no difference in the HbA1c results from the GCB and FSB specimens at normal, prediabetes, and diabetes HbA1c levels. We validated an HPLC method for measuring HbA1c in GCB; this method can be used to screen dental patients for diabetes. Copyright© by the American Society for Clinical Pathology (ASCP).

  18. Rapid Development and Validation of Improved Reversed-Phase High-performance Liquid Chromatography Method for the Quantification of Mangiferin, a Polyphenol Xanthone Glycoside in Mangifera indica

    PubMed Central

    Naveen, P.; Lingaraju, H. B.; Prasad, K. Shyam

    2017-01-01

    Mangiferin, a polyphenolic xanthone glycoside from Mangifera indica, is used as traditional medicine for the treatment of numerous diseases. The present study was aimed to develop and validate a reversed-phase high-performance liquid chromatography (RP-HPLC) method for the quantification of mangiferin from the bark extract of M. indica. RP-HPLC analysis was performed by isocratic elution with a low-pressure gradient using 0.1% formic acid: acetonitrile (87:13) as a mobile phase with a flow rate of 1.5 ml/min. The separation was done at 26°C using a Kinetex XB-C18 column as stationary phase and the detection wavelength at 256 nm. The proposed method was validated for linearity, precision, accuracy, limit of detection, limit of quantification, and robustness by the International Conference on Harmonisation guidelines. In linearity, the excellent correlation coefficient more than 0.999 indicated good fitting of the curve and also good linearity. The intra- and inter-day precision showed < 1% of relative standard deviation of peak area indicated high reliability and reproducibility of the method. The recovery values at three different levels (50%, 100%, and 150%) of spiked samples were found to be 100.47, 100.89, and 100.99, respectively, and low standard deviation value < 1% shows high accuracy of the method. In robustness, the results remain unaffected by small variation in the analytical parameters, which shows the robustness of the method. Liquid chromatography–mass spectrometry analysis confirmed the presence of mangiferin with M/Z value of 421. The assay developed by HPLC method is a simple, rapid, and reliable for the determination of mangiferin from M. indica. SUMMARY The present study was intended to develop and validate an RP-HPLC method for the quantification of mangiferin from the bark extract of M. indica. The developed method was validated for linearity, precision, accuracy, limit of detection, limit of quantification and robustness by International Conference on Harmonization guidelines. This study proved that the developed assay by HPLC method is a simple, rapid and reliable for the quantification of the mangiferin from M. indica. Abbreviations Used: M. indica: Mangifera indica, RP-HPLC: Reversed-phase high-performance liquid chromatography, M/Z: Mass to charge ratio, ICH: International conference on harmonization, % RSD: Percentage of relative standard deviation, ppm: Parts per million, LOD: Limit of detection, LOQ: Limit of quantification. PMID:28539748

  19. Rapid Development and Validation of Improved Reversed-Phase High-performance Liquid Chromatography Method for the Quantification of Mangiferin, a Polyphenol Xanthone Glycoside in Mangifera indica.

    PubMed

    Naveen, P; Lingaraju, H B; Prasad, K Shyam

    2017-01-01

    Mangiferin, a polyphenolic xanthone glycoside from Mangifera indica , is used as traditional medicine for the treatment of numerous diseases. The present study was aimed to develop and validate a reversed-phase high-performance liquid chromatography (RP-HPLC) method for the quantification of mangiferin from the bark extract of M. indica . RP-HPLC analysis was performed by isocratic elution with a low-pressure gradient using 0.1% formic acid: acetonitrile (87:13) as a mobile phase with a flow rate of 1.5 ml/min. The separation was done at 26°C using a Kinetex XB-C18 column as stationary phase and the detection wavelength at 256 nm. The proposed method was validated for linearity, precision, accuracy, limit of detection, limit of quantification, and robustness by the International Conference on Harmonisation guidelines. In linearity, the excellent correlation coefficient more than 0.999 indicated good fitting of the curve and also good linearity. The intra- and inter-day precision showed < 1% of relative standard deviation of peak area indicated high reliability and reproducibility of the method. The recovery values at three different levels (50%, 100%, and 150%) of spiked samples were found to be 100.47, 100.89, and 100.99, respectively, and low standard deviation value < 1% shows high accuracy of the method. In robustness, the results remain unaffected by small variation in the analytical parameters, which shows the robustness of the method. Liquid chromatography-mass spectrometry analysis confirmed the presence of mangiferin with M/Z value of 421. The assay developed by HPLC method is a simple, rapid, and reliable for the determination of mangiferin from M. indica . The present study was intended to develop and validate an RP-HPLC method for the quantification of mangiferin from the bark extract of M. indica . The developed method was validated for linearity, precision, accuracy, limit of detection, limit of quantification and robustness by International Conference on Harmonization guidelines. This study proved that the developed assay by HPLC method is a simple, rapid and reliable for the quantification of the mangiferin from M. indica . Abbreviations Used: M. indica : Mangifera indica , RP-HPLC: Reversed-phase high-performance liquid chromatography, M/Z: Mass to charge ratio, ICH: International conference on harmonization, % RSD: Percentage of relative standard deviation, ppm: Parts per million, LOD: Limit of detection, LOQ: Limit of quantification.

  20. Analysis of anti-neoplastic drug in bacterial ghost matrix, w/o/w double nanoemulsion and w/o nanoemulsion by a validated 'green' liquid chromatographic method.

    PubMed

    Youssof, Abdullah M E; Salem-Bekhit, Mounir M; Shakeel, Faiyaz; Alanazi, Fars K; Haq, Nazrul

    2016-07-01

    The objective of the present investigation was to develop and validate a 'green' reversed phase high-performance liquid chromatography (RP-HPLC) method for rapid analysis of a cytotoxic drug 5-fluorouracil (5-FU) in bulk drug, marketed injection, water-in-oil (w/o) nanoemulsion, double water-in-oil-in-water (w/o/w) nanoemulsion and bacterial ghost (BG) matrix. The chromatography study was carried out at room temperature (25±1°C) using an HPLC system with the help of ultraviolet (UV)-visible detector. The chromatographic performance was achieved with a Nucleodur 150mm×4.6mm RP C8 column filled with 5µm filler as a static phase. The mobile phase consisted of ethyl acetate: methanol (7:3% v/v) which was delivered at a flow rate of 1.0mLmin(-1) and the drug was detected in UV mode at 254nm. The developed method was validated in terms of linearity (r(2)=0.998), accuracy (98.19-102.09%), precision (% RSD=0.58-1.17), robustness (% RSD=0.12-0.53) and sensitivity with satisfactory results. The efficiency of the method was demonstrated by the assay of the drug in marketed injection, w/o nanoemulsion, w/o/w nanoemulsion and BG with satisfactory results. The successful resolution of the drug along with its degradation products clearly established the stability-indicating nature of the proposed method. Overall, these results suggested that the proposed analytical method could be effectively applied to the routine analysis of 5-FU in bulk drug, various pharmaceutical dosage forms and BG. Copyright © 2016 Elsevier B.V. All rights reserved.

  1. Stability of dronabinol capsules when stored frozen, refrigerated, or at room temperature.

    PubMed

    Wempe, Michael F; Oldland, Alan; Stolpman, Nancy; Kiser, Tyree H

    2016-07-15

    Results of a study to determine the 90-day stability of dronabinol capsules stored under various temperature conditions are reported. High-performance liquid chromatography (HPLC) with ultraviolet (UV) detection was used to assess the stability of dronabinol capsules (synthetic delta-9-tetrahydrocannabinol [Δ9-THC] mixed with high-grade sesame oil and other inactive ingredients and encapsulated as soft gelatin capsules) that were frozen, refrigerated, or kept at room temperature for three months. The dronabinol capsules remained in the original foil-sealed blister packs until preparation for HPLC-UV assessment. The primary endpoint was the percentage of the initial Δ9-THC concentration remaining at multiple designated time points. The secondary aim was to perform forced-degradation studies under acidic conditions to demonstrate that the HPLC-UV method used was stability indicating. The appearance of the dronabinol capsules remained unaltered during frozen, cold, or room-temperature storage. Regardless of storage condition, the percentage of the initial Δ9-THC content remaining was greater than 97% for all evaluated samples at all time points over the three-month study. These experimental data indicate that the product packaging and the sesame oil used to formulate dronabinol capsules efficiently protect Δ9-THC from oxidative degradation to cannabinol; this suggests that pharmacies can store dronabinol capsules in nonrefrigerated automated dispensing systems, with a capsule expiration date of 90 days after removal from the refrigerator. Dronabinol capsules may be stored at room temperature in their original packaging for up to three months without compromising capsule appearance and with minimal reduction in Δ9-THC concentration. Copyright © 2016 by the American Society of Health-System Pharmacists, Inc. All rights reserved.

  2. Determination of CMPO using HPLC -UV

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Gracy Elias; Gary S. Groenewold; Bruce J. Mincher

    Octyl(phenyl)-N,N-diisobutylcarbamoylmethylphosphine oxide (CMPO) is an extractant proposed for selective separation of radionuclide metals from used nuclear fuel solutions using solvent extraction. Radiolysis reactions can degrade CMPO and reduce separation performance and hence methods for measuring concentration of CMPO and identifying degradation products are needed. A novel high performance liquid chromatography (HPLC) method employing ultraviolet detection (UV) was developed to detect and quantitate CMPO in dodecane. Some radiolysis products in gamma and alpha irradiated CMPO solutions were identified using HPLC/electrospray ionization-mass spectrometry (ESI-MS). Validation data indicated that the HPLC-UV method for CMPO determination provided good linearity, sensitivity, procedure accuracy and systemmore » precision. CMPO-nitric acid complexes were also identified, that account for the apparent loss of CMPO in acidic environment, independent of irradiation.« less

  3. Validated hydrophilic interaction LC-MS/MS method for simultaneous quantification of dacarbazine and 5-amino-4-imidazole-carboxamide in human plasma.

    PubMed

    Liu, Yanhong; Zhang, Weihua; Yang, Yuhui

    2008-10-19

    A hydrophilic interaction high performance liquid chromatography-tandem mass spectrometric method has been developed and validated for simultaneous quantification of dacarbazine (DTIC) and its terminal metabolite, 5-amino-4-imidazole-carboxamide (AIC) in human plasma. The plasma samples are first extracted by a C8+SCX mixed-mode 96-well plate to extend the extraction stability of DTIC and AIC. The extracted residues are further cleaned by a primary and secondary amine (PSA) adsorbent for minimization of matrix effect. Analyses are done on an Amide-80 HPLC column coupled to a tandem mass spectrometer fitted with an atmospheric pressure turbo ion spray ionization interface in the positive-ion mode. Both DTIC and AIC have reproducible retention times on the Amide-80 HPLC column. This type of column not only has an excellent column life (over 4000 injections), but also has zero carryover effect. The injection volume should be limited at 10 microL or less to avoid the peak splitting. The validated concentration ranges are from 0.5 to 500 ng/mL for DTIC and from 2.0 to 500 ng/mL for AIC. The validated method has been successfully applied to determine the pharmacokinetic profiles for human patients receiving DTIC infusions.

  4. Stability Indicating HPLC Method for the Determination of Chiral Purity of R-(-)-5-[2-aminopropyl]-2-methoxybenzene Sulfonamide.

    PubMed

    Kasawar, G B; Farooqui, M N

    2009-09-01

    A chiral reverse phase liquid chromatographic method was developed for the enantiomeric resolution of racemic mixture of (-)-5-[2-aminopropyl]-2-methoxybenzene sulfonamide in bulk drug. The enantiomeric separation of sulfonamide was resolved on a Crownpak CR (+) column using perchloric acid buffer of pH 1.0 as mobile phase and with UV detection at 226 nm. The method is validated and proved to be robust. The limit of detection and quantification of S (-)-(5)-[2-aminopropyl]-2-methoxybenzene sulfonamide] was found to be 0.084 and 0.159 mug/ml, respectively for 20 mul injection volume. The percentage recovery of S (-)-(5)-[2-aminopropyl]-2-methoxybenzene sulfonamide] ranged from 99.57 to 101.88 in bulk drug samples of R (-)-(5)-[2- aminopropyl]-2-methoxybenzene sulfonamide].

  5. Stability Indicating HPLC Method for the Determination of Chiral Purity of R-(-)-5-[2-aminopropyl]-2-methoxybenzene Sulfonamide

    PubMed Central

    Kasawar, G. B.; Farooqui, M. N.

    2009-01-01

    A chiral reverse phase liquid chromatographic method was developed for the enantiomeric resolution of racemic mixture of (-)-5-[2-aminopropyl]-2-methoxybenzene sulfonamide in bulk drug. The enantiomeric separation of sulfonamide was resolved on a Crownpak CR (+) column using perchloric acid buffer of pH 1.0 as mobile phase and with UV detection at 226 nm. The method is validated and proved to be robust. The limit of detection and quantification of S (-)-(5)-[2-aminopropyl]-2-methoxybenzene sulfonamide] was found to be 0.084 and 0.159 μg/ml, respectively for 20 μl injection volume. The percentage recovery of S (-)-(5)-[2-aminopropyl]-2-methoxybenzene sulfonamide] ranged from 99.57 to 101.88 in bulk drug samples of R (-)-(5)-[2- aminopropyl]-2-methoxybenzene sulfonamide]. PMID:20502572

  6. Studies on the stability of preservatives under subcritical water conditions.

    PubMed

    Kapalavavi, B; Marple, R; Gamsky, C; Yang, Y

    2015-06-01

    The goal of this work was to further validate the subcritical water chromatography (SBWC) methods for separation and analysis of preservatives through the evaluation of analyte stability in subcritical water. In this study, the degradation of preservatives was investigated at temperatures of 100-200°C using two different approaches. First, the peak areas obtained by SBWC at high temperatures were compared with those achieved using the traditional high-performance liquid chromatography (HPLC) at 25°C. In the second approach, several preservatives and water were loaded into a vessel and heated at high temperatures for 30 or 60 min. The heated mixtures were then analysed by GC/MS to determine the stability of preservatives. The t- and F-test on the results of the first approach reveal that the peak areas achieved by HPLC and SBWC are not significantly different at the 95% confidence level, meaning that the preservatives studied are stable during the high-temperature SBWC runs. Although the results of the second approach show approximately 10% degradation of preservatives into mainly p-hydroxybenzoic acid and phenol at 200°C, the preservatives studied are stable at 100 and 150°C. This is in good agreement with the validation results obtained by the first approach. The findings of this work confirm that SBWC methods at temperatures up to 150°C are reliable for separation and analysis of preservatives in cosmetic and other samples. © 2014 Society of Cosmetic Scientists and the Société Française de Cosmétologie.

  7. Hydrogen sulfide measurement using sulfide dibimane: critical evaluation with electrospray ion trap mass spectrometry

    PubMed Central

    Shen, Xinggui; Chakraborty, Sourav; Dugas, Tammy R; Kevil, Christopher G

    2015-01-01

    Accurate measurement of hydrogen sulfide bioavailability remains a technical challenge due to numerous issues involving sample processing, detection methods used, and actual biochemical products measured. Our group and others have reported that reverse phase HPLC detection of sulfide dibimane (SDB) product from the reaction of H2S/HS− with monobromobimane allows for analytical detection of hydrogen sulfide bioavailability in free and other biochemical forms. However, it remains unclear whether possible interfering contaminants may contribute to HPLC SDB peak readings that may result in inaccurate measurements of bioavailable sulfide. In this study, we critically compared hydrogen sulfide dependent SDB detection using reverse phase HPLC (RP-HPLC) versus quantitative SRM electrospray ionization mass spectrometry (ESI/MS) to obtain greater clarity into the validity of the reverse phase HPLC method for analytical measurement of hydrogen sulfide. Using an LCQ-deca ion-trap mass spectrometer, SDB was identified by ESI/MS positive ion mode, and quantified by selected reaction monitoring (SRM) using hydrocortisone as an internal standard. Collision induced dissociation (CID) parameters were optimized at MS2 level for SDB and hydrocortisone. ESI/MS detection of SDB standard was found to be a log order more sensitive than RP-HPLC with a lower limit of 0.25 nM. Direct comparison of tissue and plasma SDB levels using RP-HPLC and ESI/MS methods revealed comparable sulfide levels in plasma, aorta, heart, lung and brain. Together, these data confirm the use of SDB as valid indicator of H2S bioavailability and highlights differences between analytical detection methods. PMID:24932544

  8. Spectrum-effect relationship between HPLC fingerprints and hypolipidemic effect of Curcuma aromatica.

    PubMed

    Liu, Meiqiong; Wu, Youjiao; Huang, Shushi; Liu, Huagang; Feng, Jie

    2018-02-23

    Curcuma aromatica is used as a traditional Chinese medicine, and it is mainly distributed in Guangxi, China. In this study, 10 batches of C. aromatica were collected from different origins in Guangxi. The fingerprints were established by HPLC technique to investigate the quality stability of C. aromatica. The spectrum-effect relationship between HPLC fingerprints and hypolipidemic effect of C. aromatica was assessed by similarity analysis, gray relational analysis and multiple linear regression analysis. From the results, the similarity values between each batch of C. aromatica and reference fingerprint were >0.880, indicating the good quality stability of the 10 batches of C. aromatica. Twenty common peaks were selected as the fingerprints to evaluate the quality and hypolipidemic effect of C. aromatica. The results of spectrum-effect relationship showed that peaks 10, 18, 13, 15 and 17 in the fingerprints were closely related to hypolipidemic effect. This study successfully established the spectrum-effect relationship between HPLC fingerprints and hypolipidemic effect of C. aromatica, which provided methods for quality control and more effectively studies on bioactive compounds of C. aromatica. It could also provide a new simple and effective method for utilizing the fingerprints to optimize the Chinese prescription and develop traditional Chinese medicine. Copyright © 2018 John Wiley & Sons, Ltd.

  9. Formulation, stability study, and pre-clinical evaluation of a vaginal cream containing curcumin in a rat model of vulvovaginal candidiasis.

    PubMed

    de Souza Fernandes, Lígia; Amorim, Yuri Martins; Silva, Elton Libério da; Silva, Samuel Calixto; Santos, Alécia Junia Aparecida; Peixoto, Franciele Natália; Pires, Luara Moniele Neves; Sakamoto, Raquel Yumi; Pinto, Flávia do Carmo Horta; Scarpa, Maria Virgínia Costa; Gonzaga de Freitas Araújo, Marcelo

    2018-03-08

    Owing to the growing resistance among isolates of Candida species to usual antifungal agents and the well-known therapeutic potential of curcumin, the purpose of this study was to develop and validate a vaginal formulation containing this substance and to evaluating its effectiveness in the treatment of experimental vulvovaginal candidiasis METHODS: Curcumin was incorporated in a vaginal cream in three concentrations (0.01, 0.1 and 1.0%). The different concentrations of the cream and its controls were intravaginally administered in an immunosuppressed rat model to evaluate the efficacy in the treatment of experimental vulvovaginal candidiasis. Samples of the cream were also subjected to centrifugation and physical stability tests and an analytical method for quantification of curcumin was validated based on HPLC RESULTS: The formulation was stable and the HPLC method could be considered suitable for the quantitative determination of curcumin in the cream. After six days of pre-clinical study, the number of infected animals was 1/6 in all groups treated with curcumin vaginal cream and the fungal burden showed a progressive reduction. Reduction of the inflammatory infiltrate was observed in the group treated with 1.0% cream CONCLUSION: Vaginal cream containing curcumin could be considered a promising effective antifungal medicine in the treatment of vulvovaginal candidiasis. This article is protected by copyright. All rights reserved. This article is protected by copyright. All rights reserved.

  10. Development of New Method for Simultaneous Analysis of Piracetam and Levetiracetam in Pharmaceuticals and Biological Fluids: Application in Stability Studies

    PubMed Central

    Siddiqui, Farhan Ahmed; Sher, Nawab; Shafi, Nighat; Wafa Sial, Alisha; Ahmad, Mansoor; Mehjebeen

    2014-01-01

    RP-HPLC ultraviolet detection simultaneous quantification of piracetam and levetiracetam has been developed and validated. The chromatography was obtained on a Nucleosil C18 column of 25 cm × 0.46 cm, 10 μm, dimension. The mobile phase was a (70 : 30 v/v) mixture of 0.1 g/L of triethylamine and acetonitrile. Smooth flow of mobile phase at 1 mL/min was set and 205 nm wavelength was selected. Results were evaluated through statistical parameters which qualify the method reproducibility and selectivity for the quantification of piracetam, levetiracetam, and their impurities hence proving stability-indicating properties. The proposed method is significantly important, permitting the separation of the main constituent piracetam from levetiracetam. Linear behavior was observed between 20 ng/mL and 10000 ng/mL for both drugs. The proposed method was checked in bulk drugs, dosage formulations, physiological condition, and clinical investigations and excellent outcome was witnessed. PMID:25114921

  11. The Second SeaWiFS HPLC Analysis Round-Robin Experiment (SeaHARRE-2)

    NASA Technical Reports Server (NTRS)

    2005-01-01

    Eight international laboratories specializing in the determination of marine pigment concentrations using high performance liquid chromatography (HPLC) were intercompared using in situ samples and a variety of laboratory standards. The field samples were collected primarily from eutrophic waters, although mesotrophic waters were also sampled to create a dynamic range in chlorophyll concentration spanning approximately two orders of magnitude (0.3 25.8 mg m-3). The intercomparisons were used to establish the following: a) the uncertainties in quantitating individual pigments and higher-order variables (sums, ratios, and indices); b) an evaluation of spectrophotometric versus HPLC uncertainties in the determination of total chlorophyll a; and c) the reduction in uncertainties as a result of applying quality assurance (QA) procedures associated with extraction, separation, injection, degradation, detection, calibration, and reporting (particularly limits of detection and quantitation). In addition, the remote sensing requirements for the in situ determination of total chlorophyll a were investigated to determine whether or not the average uncertainty for this measurement is being satisfied. The culmination of the activity was a validation of the round-robin methodology plus the development of the requirements for validating an individual HPLC method. The validation process includes the measurements required to initially demonstrate a pigment is validated, and the measurements that must be made during sample analysis to confirm a method remains validated. The so-called performance-based metrics developed here describe a set of thresholds for a variety of easily-measured parameters with a corresponding set of performance categories. The aggregate set of performance parameters and categories establish a) the overall performance capability of the method, and b) whether or not the capability is consistent with the required accuracy objectives.

  12. Determination of rivaroxaban in patient's plasma samples by anti-Xa chromogenic test associated to High Performance Liquid Chromatography tandem Mass Spectrometry (HPLC-MS/MS).

    PubMed

    Derogis, Priscilla Bento Matos; Sanches, Livia Rentas; de Aranda, Valdir Fernandes; Colombini, Marjorie Paris; Mangueira, Cristóvão Luis Pitangueira; Katz, Marcelo; Faulhaber, Adriana Caschera Leme; Mendes, Claudio Ernesto Albers; Ferreira, Carlos Eduardo Dos Santos; França, Carolina Nunes; Guerra, João Carlos de Campos

    2017-01-01

    Rivaroxaban is an oral direct factor Xa inhibitor, therapeutically indicated in the treatment of thromboembolic diseases. As other new oral anticoagulants, routine monitoring of rivaroxaban is not necessary, but important in some clinical circumstances. In our study a high-performance liquid chromatography-tandem mass spectrometry (HPLC-MS/MS) method was validated to measure rivaroxaban plasmatic concentration. Our method used a simple sample preparation, protein precipitation, and a fast chromatographic run. It was developed a precise and accurate method, with a linear range from 2 to 500 ng/mL, and a lower limit of quantification of 4 pg on column. The new method was compared to a reference method (anti-factor Xa activity) and both presented a good correlation (r = 0.98, p < 0.001). In addition, we validated hemolytic, icteric or lipemic plasma samples for rivaroxaban measurement by HPLC-MS/MS without interferences. The chromogenic and HPLC-MS/MS methods were highly correlated and should be used as clinical tools for drug monitoring. The method was applied successfully in a group of 49 real-life patients, which allowed an accurate determination of rivaroxaban in peak and trough levels.

  13. Stability of cyclosporine solutions stored in polypropylene-polyolefin bags and polypropylene syringes.

    PubMed

    Li, Mengqing; Forest, Jean-Marc; Coursol, Christian; Leclair, Grégoire

    2011-09-01

    The stability of cyclosporine diluted to 0.2 or 2.5 mg/mL with 0.9% sodium chloride injection or 5% dextrose injection and stored in polypropylene-polyolefin containers or polypropylene syringes was evaluated. Intravenous cyclosporine solutions (0.2 and 2.5 mg/mL) were aseptically prepared and transferred to 250-mL polypropylene-polyolefin bags or 60-mL polypropylene syringes. Chemical stability was measured using a stability-indicating high-performance liquid chromatography (HPLC) assay. Physical stability was assessed by visual inspection and a dynamic light scattering (DLS) method. After 14 days, HPLC assay showed that the samples of i.v. cyclosporine stored in polypropylene-polyolefin bags remained chemically stable (>98% of initial amount remaining); the physical stability of the samples was confirmed by DLS and visual inspection. The samples stored in polypropylene syringes were found to contain an impurity (attributed to leaching of a syringe component by the solution) that could be detected by HPLC after 1 day; on further investigation, no leaching was detected when the syringes were exposed to undiluted i.v. cyclosporine 50 mg/mL for 10 minutes. Samples of i.v. cyclosporine solutions of 0.2 and 2.5 mg/mL diluted in 0.9% sodium chloride injection or 5% dextrose injection and stored at 25 °C in polypropylene-polyolefin bags were physically and chemically stable for at least 14 days. When stored in polypropylene syringes, the samples were contaminated by an impurity within 1 day; however, the short-term (i.e., ≤10 minutes) use of the syringes for the preparation and transfer of i.v. cyclosporine solution is considered safe.

  14. Development of an Advanced HPLC-MS/MS Method for the Determination of Carotenoids and Fat-Soluble Vitamins in Human Plasma.

    PubMed

    Hrvolová, Barbora; Martínez-Huélamo, Miriam; Colmán-Martínez, Mariel; Hurtado-Barroso, Sara; Lamuela-Raventós, Rosa Maria; Kalina, Jiří

    2016-10-14

    The concentration of carotenoids and fat-soluble vitamins in human plasma may play a significant role in numerous chronic diseases such as age-related macular degeneration and some types of cancer. Although these compounds are of utmost interest for human health, methods for their simultaneous determination are scarce. A new high pressure liquid chromatography (HPLC)-tandem mass spectrometry (MS/MS) method for the quantification of selected carotenoids and fat-soluble vitamins in human plasma was developed, validated, and then applied in a pilot dietary intervention study with healthy volunteers. In 50 min, 16 analytes were separated with an excellent resolution and suitable MS signal intensity. The proposed HPLC-MS/MS method led to improvements in the limits of detection (LOD) and quantification (LOQ) for all analyzed compounds compared to the most often used HPLC-DAD methods, in some cases being more than 100-fold lower. LOD values were between 0.001 and 0.422 µg/mL and LOQ values ranged from 0.003 to 1.406 µg/mL, according to the analyte. The accuracy, precision, and stability met with the acceptance criteria of the AOAC (Association of Official Analytical Chemists) International. According to these results, the described HPLC-MS/MS method is adequately sensitive, repeatable and suitable for the large-scale analysis of compounds in biological fluids.

  15. HPLC-MS/MS method for the simultaneous determination of MB07133 and its metabolites, cytarabine and arabinofuranosyluracil, in rat plasma.

    PubMed

    Wang, Dan; Xiao, Qingqing; Yang, Wanqiu; Qian, Wei; Yang, Jin

    2016-02-20

    MB07133 is an intravenously administered cytarabine mononucleotide (araCMP) prodrug, for the treatment of hepatocellular carcinoma (HCC). A simple, selective and sensitive HPLC-MS/MS method using high pressure liquid chromatography (HPLC) coupled to triple-quadrupole mass spectrometer, was developed and validated for the detection of prodrug MB07133 and its metabolites, cytarabine (araC) and arabinofuranosyluracil (araU) in rat plasma. Protein precipitation using 3% trichloroacetic acid (TCA) was employed to extract analytes from 100μL rat plasma. Adequate separation of araC and araU from their endogenous compounds was achieved on the Synergi(®) fusion-RP column (150mm×4.6mm, 4μm) by a gradient-elution with a mobile phase consisting of ammonium formate (1mM) and methanol at a flow rate of 1mL/min. Multiple reaction monitoring mode (MRM) was applied in the detection of MB07133, araC, araU and Ganciclovir (internal standard) with ion pairs 441.2/330.2, 244.2/112.2, 245.2/113.2 and 256.1/152.2, respectively. The assays were validated with respect to specificity, linearity (100-50000ng/mL for MB07133, 2-1000ng/mL for araC and araU), accuracy and precision, extraction recovery, matrix effect and stability. The validated method has been successfully applied to an intravenous bolus pharmacokinetic study of MB07133 in male Sprague-Dawley rats (18mg/kg i.v.). Copyright © 2015 Elsevier B.V. All rights reserved.

  16. Spectrofluorometry, thin layer chromatography, and column high-performance liquid chromatography determination of rabeprazole sodium in the presence of its acidic and oxidized degradation products.

    PubMed

    Osman, Afaf Osman; Osman, Afaf; Osman, Mohamed

    2009-01-01

    The objective of this study is to develop validated stability-indicating spectrofluorometric, TLC-densitometric, and HPLC methods for the determination of rabeprazole sodium and its degradation products. The first method was based on measuring the fluorescence intensity of the drug at 416 and 311 nm for the emission and at 320 and 274 nm for the excitation for acid and oxidized solutions, respectively. The second method was based on the separation of the drug from its acidic and oxidized degradation products followed by densitometric measurement of the intact drug spot at 284 nm. The separation was carried out on Fluka TLC sheets of silica gel 60 F254 using isopropyl alcohol--30% ammonia (80 + 2, v/v) mobile phase. The third method was based on HPLC separation of rabeprazole sodium from its acidic and oxidized degradation products on a reversed-phase Waters Nova-Pak C18 column using 0.05 M potassium dihydrogen phosphate-methanol-acetonitrile (5 + 3 + 2, v/v/v) pH 7 +/- 0.2 mobile phase. The proposed procedures were successfully applied for the determination of rabeprazole sodium in pure form, laboratory-prepared mixtures, tablet, and expired batch. The obtained results were statistically compared with those of a reported method and validated according to United States Pharmacopeia guidelines. Two main acidic degradation products of the drug were separated and subjected to IR spectrometry and MS to confirm their structures, and the schemes for their formation were elucidated.

  17. Efficacy validation of synthesized retinol derivatives In vitro: stability, toxicity, and activity.

    PubMed

    Han, Hye-Sook; Kwon, Youn-Ja; Park, Myoung-Soon; Park, Si-Ho; Cho, So-Mi Kim; Rho, Young-Soy; Kim, Jin-Wou; Sin, Hong-Sig; Um, Soo-Jong

    2003-08-15

    Retinol (vitamin A) is used as an antiwrinkle agent in the cosmetics industry. However, its photo-instability makes it unsuitable for use in general cosmetic formulations. To improve the photo-stability of retinol, three derivatives (3, 4, and 5) were synthesized and their biological activities were analyzed. 1H NMR and HPLC analysis indicated that derivatives 3 and 5 were much more stable than retinol under our sunlight exposure conditions. When human adult fibroblasts were treated, the IC(50) of derivative 3 was 96 microM, which is similar to that of retinol, as determined by the MTT assay. Derivatives 4 and 5 were 2.5 and 8 times more toxic than retinol, respectively. At 1 microM treatment, like retinol, derivatives 3 and 4 were specifically active for RARalpha out of six retinoid receptors (RAR/RXRalpha, beta, gamma). Dose-dependent analysis confirmed that derivative 4 was as active as retinol and the other two derivatives were less active for RARalpha. The effect of our derivatives on the expression of collagenase, an indicator of wrinkle formation, was measured using the transient co-expression of c-Jun and RT-PCR in HaCaT cells. Collagenase promoter activity, which is increased by c-Jun expression, was reduced 42% by retinol treatment. The other derivatives inhibited collagenase promoter activity similarly. These results were further confirmed by RT-PCR analysis of the collagenase gene. Taken together, our results suggest that retinol derivative 3 is a promising antiwrinkle agent based on its higher photo-stability, lower RARalpha activity (possibly indicating reduced side effects), and similar effect on collagenase expression.

  18. A New Rapid and Sensitive Stability-Indicating UPLC Assay Method for Tolterodine Tartrate: Application in Pharmaceuticals, Human Plasma and Urine Samples.

    PubMed

    Yanamandra, Ramesh; Vadla, Chandra Sekhar; Puppala, Umamaheshwar; Patro, Balaram; Murthy, Yellajyosula L N; Ramaiah, Parimi Atchuta

    2012-01-01

    A new rapid, simple, sensitive, selective and accurate reversed-phase stability-indicating Ultra Performance Liquid Chromatography (RP-UPLC) technique was developed for the assay of Tolterodine Tartrate in pharmaceutical dosage form, human plasma and urine samples. The developed UPLC method is superior in technology to conventional HPLC with respect to speed, solvent consumption, resolution and cost of analysis. Chromatographic run time was 6 min in reversed-phase mode and ultraviolet detection was carried out at 220 nm for quantification. Efficient separation was achieved for all the degradants of Tolterodine Tartrate on BEH C18 sub-2-μm Acquity UPLC column using Trifluoroacetic acid and acetonitrile as organic solvent in a linear gradient program. The active pharmaceutical ingredient was extracted from tablet dosage form using a mixture of acetonitrile and water as diluent. The calibration graphs were linear and the method showed excellent recoveries for bulk and tablet dosage form. The test solution was found to be stable for 40 days when stored in the refrigerator between 2 and 8 °C. The developed UPLC method was validated and meets the requirements delineated by the International Conference on Harmonization (ICH) guidelines with respect to linearity, accuracy, precision, specificity and robustness. The intra-day and inter-day variation was found be less than 1%. The method was reproducible and selective for the estimation of Tolterodine Tartrate. Because the method could effectively separate the drug from its degradation products, it can be employed as a stability-indicating one.

  19. A New Rapid and Sensitive Stability-Indicating UPLC Assay Method for Tolterodine Tartrate: Application in Pharmaceuticals, Human Plasma and Urine Samples

    PubMed Central

    Yanamandra, Ramesh; Vadla, Chandra Sekhar; Puppala, Umamaheshwar; Patro, Balaram; Murthy, Yellajyosula. L. N.; Ramaiah, Parimi Atchuta

    2012-01-01

    A new rapid, simple, sensitive, selective and accurate reversed-phase stability-indicating Ultra Performance Liquid Chromatography (RP-UPLC) technique was developed for the assay of Tolterodine Tartrate in pharmaceutical dosage form, human plasma and urine samples. The developed UPLC method is superior in technology to conventional HPLC with respect to speed, solvent consumption, resolution and cost of analysis. Chromatographic run time was 6 min in reversed-phase mode and ultraviolet detection was carried out at 220 nm for quantification. Efficient separation was achieved for all the degradants of Tolterodine Tartrate on BEH C18 sub-2-μm Acquity UPLC column using Trifluoroacetic acid and acetonitrile as organic solvent in a linear gradient program. The active pharmaceutical ingredient was extracted from tablet dosage form using a mixture of acetonitrile and water as diluent. The calibration graphs were linear and the method showed excellent recoveries for bulk and tablet dosage form. The test solution was found to be stable for 40 days when stored in the refrigerator between 2 and 8 °C. The developed UPLC method was validated and meets the requirements delineated by the International Conference on Harmonization (ICH) guidelines with respect to linearity, accuracy, precision, specificity and robustness. The intra-day and inter-day variation was found be less than 1%. The method was reproducible and selective for the estimation of Tolterodine Tartrate. Because the method could effectively separate the drug from its degradation products, it can be employed as a stability-indicating one. PMID:22396907

  20. A validated HPLC-MS/MS assay for quantifying unstable pharmacologically active metabolites of clopidogrel in human plasma: application to a clinical pharmacokinetic study.

    PubMed

    Furlong, Michael T; Savant, Ishani; Yuan, Moucun; Scott, Laura; Mylott, William; Mariannino, Thomas; Kadiyala, Pathanjali; Roongta, Vikram; Arnold, Mark E

    2013-05-01

    Clopidogrel is prescribed for the treatment of Acute Coronary Syndrome and recent myocardial infarction, recent stroke, or established peripheral arterial disease. A sensitive and reliable high performance liquid chromatography-tandem mass spectrometry (HPLC-MS/MS) assay was developed and validated to enable reliable quantification of four diastereomeric and chemically reactive thiol metabolites, two of which are pharmacologically active, in human plasma. The metabolites were stabilized by alkylation of their reactive thiol moieties with 2-bromo-3'-methoxyacetophenone (MPB). Following organic solvent mediated-protein precipitation in a 96-well plate format, chromatographic separation was achieved by gradient elution on an Ascentis Express RP-amide column. Chromatographic conditions were optimized to ensure separation of the four derivatized active metabolites. Derivatized metabolites and stable isotope-labeled internal standards were detected by positive ion electrospray tandem mass spectrometry. The HPLC-MS/MS assay was validated over concentration ranges of 0.125-125 ng/mL for metabolites H1-H3 and 0.101-101 ng/mL for H4. Intra- and inter-assay precision values for replicate quality control samples were within 14.3% for all analytes during the assay validation. Mean quality control accuracy values were within ±6.3% of nominal values for all analytes. Assay recoveries were high (>79%). The four derivatized analytes were stable in human blood for at least 2 h at room temperature and on ice. The analytes were also stable in human plasma for at least 25 h at room temperature, 372 days at -20 °C and -70 °C, and following at least five freeze-thaw cycles. The validated assay was successfully applied to the quantification of all four thiol metabolites in human plasma in support of a human pharmacokinetic study. Copyright © 2013 Elsevier B.V. All rights reserved.

  1. Quality evaluation and pattern recognition analyses of marker compounds from five medicinal drugs of Rutaceae family by HPLC/PDA.

    PubMed

    Zhao, Bing Tian; Kim, Eun Jung; Son, Kun Ho; Son, Jong Keun; Min, Byung Sun; Woo, Mi Hee

    2015-08-01

    To establish a standard of quality control and to identify different origins for the Rutaceae family [Citri Unshiu Peel (CU), Citri Unshiu Immature Peel (CI), Ponciri Immature Fructus (PI), Aurantii Immature Fructus (AI), and Aurantii Fructus (AU)], 13 standards including rutin (1), narirutin (2), naringin (3), hesperidin (4), neohesperidin (5), neoponcirin (6), poncirin (7), naringenin (8), isosinensetin (9), sinensetin (10), nobiletin (11), heptamethoxyflavone (12), and tangeretin (13) were determined by high performance liquid chromatography (HPLC)/photo-diode array (PDA) analysis. A YMC ODS C18 (250 × 4.6 mm, 5 µm) column was used and the ratio of mobile phases of water (A) and acetonitrile (B) delivered to the column for gradient elution was applied. This method was fully validated with respect to linearity, accuracy, precision, stability, and robustness. The HPLC/PDA method was applied successfully to quantify 13 major compounds in the extracts of CU, CI, PI, AI, and AU. The pattern recognition analysis combined with LC chromatographic data was performed by repeated analysis of 27 reference samples in the above five Rutaceae oriental medicinal drugs. The established HPLC method was rapid and reliable for quantitative analysis and quality control of multiple components in five Rutaceae species with different origins.

  2. Microfluidic chip based nano liquid chromatography coupled to tandem mass spectrometry for the determination of abused drugs and metabolites in human hair.

    PubMed

    Zhu, Kevin Y; Leung, K Wing; Ting, Annie K L; Wong, Zack C F; Ng, Winki Y Y; Choi, Roy C Y; Dong, Tina T X; Wang, Tiejie; Lau, David T W; Tsim, Karl W K

    2012-03-01

    A microfluidic chip based nano-HPLC coupled to tandem mass spectrometry (nano-HPLC-Chip-MS/MS) has been developed for simultaneous measurement of abused drugs and metabolites: cocaine, benzoylecgonine, cocaethylene, norcocaine, morphine, codeine, 6-acetylmorphine, phencyclidine, amphetamine, methamphetamine, MDMA, MDA, MDEA, and methadone in the hair of drug abusers. The microfluidic chip was fabricated by laminating polyimide films and it integrated an enrichment column, an analytical column and a nanospray tip. Drugs were extracted from hairs by sonication, and the chromatographic separation was achieved in 15 min. The drug identification and quantification criteria were fulfilled by the triple quardropule tandem mass spectrometry. The linear regression analysis was calibrated by deuterated internal standards with all of the R(2) at least over 0.993. The limit of detection (LOD) and the limit of quantification (LOQ) were from 0.1 to 0.75 and 0.2 to 1.25 pg/mg, respectively. The validation parameters including selectivity, accuracy, precision, stability, and matrix effect were also evaluated here. In conclusion, the developed sample preparation method coupled with the nano-HPLC-Chip-MS/MS method was able to reveal the presence of drugs in hairs from the drug abusers, with the enhanced sensitivity, compared with the conventional HPLC-MS/MS.

  3. Stability studies of crude plant material of Bacopa monnieri and quantitative determination of bacopaside I and bacoside A by HPLC.

    PubMed

    Srivastava, Pratibha; Raut, Hema N; Puntambekar, Hemalata M; Desai, Anagha C

    2012-01-01

    Bacopa monnieri (BM) contains several dammarane-type triterpenoid saponins including bacopaside I and bacoside A. These bioactive compounds may be used as chemical markers for the quality control of different BM products used for promoting mental health and intellect. Quantification of bacopaside I and bacoside A in crude plant material of BM stored under the stability study conditions by HPLC. Crude BM samples were stored at long-term (LS; 30°C and 65% RH), accelerated (AS; 40°C and 75% RH) and real-time (RT) study conditions. HPLC of BM extracts was carried out using a LiChroCART Purospher® STAR RP-18 endcapped column along with a guard column, Purospher STAR RP 18e 4.0 4.0 mm 5 µm using a gradient of acetonitrile (A) and water containing 0.05% (v/v) orthophosphoric acid (B) at a flow rate 1.5 mL/min with UV detection at 205 nm. The linear range of bacopaside I and bacoside A was 0.2 to 1 mg/mL. With the help of a regression equation the coefficient of determination (r²) values for bacopaside I and bacoside A were found to be > 0.999 and > 0.994 respectively. Relative standard deviation (RSD) values were < 4.0 for all the concentrations injected (n = 3). The HPLC study indicated that BM samples kept under LS condition are rich in saponin contents as compared with the samples stored under AS and RT study conditions. The study indicated that BM plant material should be used fresh to obtain maximum concentration of active saponins or it should be stored under LS conditions up to 3 months. Copyright © 2012 John Wiley & Sons, Ltd.

  4. Composition and stability of phytochemicals in five varieties of black soybeans (glycine max)

    USDA-ARS?s Scientific Manuscript database

    Phytochemical compositions of five varieties of black soybeans (Glycine max) and their stabilities at room temperature, 4 deg.C and -80 deg.C over 14 months were determined by HPLC systems with electrochemical (HPLC-ECD) and UV detectors. Polyphenol profiling was carried out by liquid chromatography...

  5. Characterization of the isomeric configuration and impurities of (Z)-endoxifen by 2D NMR, high resolution LC⬜MS, and quantitative HPLC analysis.

    PubMed

    Elkins, Phyllis; Coleman, Donna; Burgess, Jason; Gardner, Michael; Hines, John; Scott, Brendan; Kroenke, Michelle; Larson, Jami; Lightner, Melissa; Turner, Gregory; White, Jonathan; Liu, Paul

    2014-01-01

    (Z)-Endoxifen (4-hydroxy-N-desmethyltamoxifen), an active metabolite generated via actions of CYP3A4/5 and CYP2D6, is a more potent selective estrogen receptor modulator (SERM) than tamoxifen. In the MCF-7 human mammary tumor xenograft model with female athymic mice, (Z)-endoxifen, at an oral dose of 4⬜8 mg/kg, significantly inhibits tumor growth. (Z)-Endoxifen's potential as an alternative therapeutic agent independent of CYP2D6 activities, which can vary widely in ER+ breast cancer patients, is being actively evaluated. This paper describes confirmation of the configuration of the active (Z)-isomer through 2D NMR experiments, including NOE (ROESY) to establish spatial proton⬜proton correlations, and identification of the major impurity as the (E)-isomer in endoxifen drug substance by HPLC/HRMS (HPLC/MS-TOF). Stability of NMR solutions was confirmed by HPLC/UV analysis. For pre-clinical studies, a reverse-phase HPLC⬜UV method, with methanol/water mobile phases containing 10 mM ammonium formate at pH 4.3, was developed and validated for the accurate quantitation and impurity profiling of drug substance and drug product. Validation included demonstration of linearity, method precision, accuracy, and specificity in the presence of impurities, excipients (for the drug product), and degradation products. Ruggedness and reproducibility of the method were confirmed by collaborative studies between two independent laboratories. The method is being applied for quality control of the API and oral drug product. Kinetic parameters of Z- to E-isomerization were also delineated in drug substance and in aqueous formulation, showing conversion at temperatures above 25 °C. Copyright © 2014 Elsevier B.V. All rights reserved.

  6. HPLC-MS method for the quantification of nine anti-HIV drugs from dry plasma spot on glass filter and their long term stability in different conditions.

    PubMed

    D'Avolio, Antonio; Simiele, Marco; Siccardi, Marco; Baietto, Lorena; Sciandra, Mauro; Bonora, Stefano; Di Perri, Giovanni

    2010-09-05

    A bioanalytical method for the determination of most commonly prescribed protease inhibitors (saquinavir, atazanavir, amprenavir, darunavir, lopinavir and ritonavir) and non-nucleoside reverse transcriptase inhibitors (etravirine, efavirenz and nevirapine) was developed, modifying our previous HPLC-MS chromatographic run, validated and a complete short and long term stability evaluation was carried out. One hundred microlitres of plasma were distributed on a collection glass paper filter (Glass-Microfibre from Sartorius), then the filter underwent thermal treatment, both for drying and for HIV inactivation, and stored at room temperature, 4 degrees C and -20 degrees C. The analytes were extracted from the filter disc using tert-butylmethylether with basic pH, after the addition of the internal standards quinoxaline. The extract was dried, reconstituted and the chromatographic separation was performed on a reversed-phase C-18 column (150 mm x 2.0 mm) and the analytes were quantified using a single quadrupole mass spectrometer. The method was validated considering the concentration ranges encountered in clinical trials and the routine clinical practice. The assay was linear over the concentration ranges tested. Accuracies ranged from 92.1% to 111.9% and intra-day and inter-day relative standard deviation for all quality control levels ranged from 0.2 to 12.9 and 3.1 to 14.4, respectively. Analytes in dried plasma spots were stable for longer time when dried/inactivation step was carried out before storage compared to samples not dried/inactivated before the analysis. The dried/inactivation step allows shipment of samples at room temperature without any risks, therefore the developed and validated method enables an easy and cheap sample shipment for therapeutic drug monitoring and pharmacokinetic studies. 2010 Elsevier B.V. All rights reserved.

  7. Determination of rivaroxaban in patient’s plasma samples by anti-Xa chromogenic test associated to High Performance Liquid Chromatography tandem Mass Spectrometry (HPLC-MS/MS)

    PubMed Central

    Derogis, Priscilla Bento Matos; Sanches, Livia Rentas; de Aranda, Valdir Fernandes; Colombini, Marjorie Paris; Mangueira, Cristóvão Luis Pitangueira; Katz, Marcelo; Faulhaber, Adriana Caschera Leme; Mendes, Claudio Ernesto Albers; Ferreira, Carlos Eduardo dos Santos; França, Carolina Nunes; Guerra, João Carlos de Campos

    2017-01-01

    Rivaroxaban is an oral direct factor Xa inhibitor, therapeutically indicated in the treatment of thromboembolic diseases. As other new oral anticoagulants, routine monitoring of rivaroxaban is not necessary, but important in some clinical circumstances. In our study a high-performance liquid chromatography-tandem mass spectrometry (HPLC-MS/MS) method was validated to measure rivaroxaban plasmatic concentration. Our method used a simple sample preparation, protein precipitation, and a fast chromatographic run. It was developed a precise and accurate method, with a linear range from 2 to 500 ng/mL, and a lower limit of quantification of 4 pg on column. The new method was compared to a reference method (anti-factor Xa activity) and both presented a good correlation (r = 0.98, p < 0.001). In addition, we validated hemolytic, icteric or lipemic plasma samples for rivaroxaban measurement by HPLC-MS/MS without interferences. The chromogenic and HPLC-MS/MS methods were highly correlated and should be used as clinical tools for drug monitoring. The method was applied successfully in a group of 49 real-life patients, which allowed an accurate determination of rivaroxaban in peak and trough levels. PMID:28170419

  8. Conformational stability of pGEX-expressed Schistosoma japonicum glutathione S-transferase: a detoxification enzyme and fusion-protein affinity tag.

    PubMed Central

    Kaplan, W.; Hüsler, P.; Klump, H.; Erhardt, J.; Sluis-Cremer, N.; Dirr, H.

    1997-01-01

    A glutathione S-transferase (Sj26GST) from Schistosoma japonicum, which functions in the parasite's Phase II detoxification pathway, is expressed by the Pharmacia pGEX-2T plasmid and is used widely as a fusion-protein affinity tag. It contains all 217 residues of Sj26GST and an additional 9-residue peptide linker with a thrombin cleavage site at its C-terminus. Size-exclusion HPLC (SEC-HPLC) and SDS-PAGE studies indicate that purification of the homodimeric protein under nonreducing conditions results in the reversible formation of significant amounts of 160-kDa and larger aggregates without a loss in catalytic activity. The basis for oxidative aggregation can be ascribed to the high degree of exposure of the four cysteine residues per subunit. The conformational stability of the dimeric protein was studied by urea- and temperature-induced unfolding techniques. Fluorescence-spectroscopy, SEC-HPLC, urea- and temperature-gradient gel electrophoresis, differential scanning microcalorimetry, and enzyme activity were employed to monitor structural and functional changes. The unfolding data indicate the absence of thermodynamically stable intermediates and that the unfolding/refolding transition is a two-state process involving folded native dimer and unfolded monomer. The stability of the protein was found to be dependent on its concentration, with a delta G degree (H2O) = 26.0 +/- 1.7 kcal/mol. The strong relationship observed between the m-value and the size of the protein indicates that the amount of protein surface area exposed to solvent upon unfolding is the major structural determinant for the dependence of the protein's free energy of unfolding on urea concentration. Thermograms obtained by differential scanning microcalorimetry also fitted a two-state unfolding transition model with values of delta Cp = 7,440 J/mol per K, delta H = 950.4 kJ/mol, and delta S = 1,484 J/mol. PMID:9041642

  9. Conformational stability of pGEX-expressed Schistosoma japonicum glutathione S-transferase: a detoxification enzyme and fusion-protein affinity tag.

    PubMed

    Kaplan, W; Hüsler, P; Klump, H; Erhardt, J; Sluis-Cremer, N; Dirr, H

    1997-02-01

    A glutathione S-transferase (Sj26GST) from Schistosoma japonicum, which functions in the parasite's Phase II detoxification pathway, is expressed by the Pharmacia pGEX-2T plasmid and is used widely as a fusion-protein affinity tag. It contains all 217 residues of Sj26GST and an additional 9-residue peptide linker with a thrombin cleavage site at its C-terminus. Size-exclusion HPLC (SEC-HPLC) and SDS-PAGE studies indicate that purification of the homodimeric protein under nonreducing conditions results in the reversible formation of significant amounts of 160-kDa and larger aggregates without a loss in catalytic activity. The basis for oxidative aggregation can be ascribed to the high degree of exposure of the four cysteine residues per subunit. The conformational stability of the dimeric protein was studied by urea- and temperature-induced unfolding techniques. Fluorescence-spectroscopy, SEC-HPLC, urea- and temperature-gradient gel electrophoresis, differential scanning microcalorimetry, and enzyme activity were employed to monitor structural and functional changes. The unfolding data indicate the absence of thermodynamically stable intermediates and that the unfolding/refolding transition is a two-state process involving folded native dimer and unfolded monomer. The stability of the protein was found to be dependent on its concentration, with a delta G degree (H2O) = 26.0 +/- 1.7 kcal/mol. The strong relationship observed between the m-value and the size of the protein indicates that the amount of protein surface area exposed to solvent upon unfolding is the major structural determinant for the dependence of the protein's free energy of unfolding on urea concentration. Thermograms obtained by differential scanning microcalorimetry also fitted a two-state unfolding transition model with values of delta Cp = 7,440 J/mol per K, delta H = 950.4 kJ/mol, and delta S = 1,484 J/mol.

  10. A Pilot Chemical and Physical Stability Study of Extemporaneously Compounded Levetiracetam Intravenous Solution.

    PubMed

    Raphael, Chenzira D; Zhao, Fang; Hughes, Susan E; Juba, Katherine M

    2015-01-01

    Levetiracetam is a commonly used antiepileptic medication for tumor-related epilepsy. However, the 100 mL intravenous (IV) infusion volume can be burdensome to imminently dying hospice patients. A reduced infusion volume would improve patient tolerability. The purpose of this study was to evaluate the stability of 1000 mg/25 mL (40 mg/mL) levetiracetam IV solution in sodium chloride 0.9%. We prepared levetiracetam 40 mg/mL IV solution and added it to polyvinyl chloride (PVC) bags, polyolefin bags, and polypropylene syringes. Triplicate samples of each product were stored at refrigeration (2-8°C) and analyzed on days 0, 1, 4, 7, and 14. Samples were subjected to visual inspection, pH measurement, and stability-indicating high-performance liquid chromatography (HPLC) analysis. Over the 2-week storage period, there was no significant change in visual appearance or pH for any of the stability samples. The HPLC results confirmed that all stability samples retained 94.2-101.3% of initial drug concentration and no degradation products or leachable material from the packaging materials were observed. We conclude that levetiracetam 1000 mg/25 mL IV solution in sodium chloride 0.9% is physically and chemically stable for up to 14 days under refrigeration in polypropylene syringes, PVC bags, and polyolefin bags.

  11. Development and application of a validated stability-indicating high-performance liquid chromatographic method using photodiode array detection for simultaneous determination of granisetron, methylparaben, propylparaben, sodium benzoate, and their main degradation products in oral pharmaceutical preparations.

    PubMed

    Hewala, Ismail; El-Fatatry, Hamed; Emam, Ehab; Mabrouk, Mokhtar

    2011-01-01

    A simple, rapid, and sensitive RP-HPLC method using photodiode array detection was developed and validated for the simultaneous determination of granisetron hydrochloride, 1-methyl-1H-indazole-3-carboxylic acid (the main degradation product of granisetron), sodium benzoate, methylparaben, propylparaben, and 4-hydroxybenzoic acid (the main degradation product of parabens) in granisetron oral drops and solutions. The separation of the compounds was achieved within 8 min on a SymmetryShield RP18 column (100 x 4.6 mm id, 3.5 microm particle size) using the mobile phase acetonitrile--0.05 M KH2PO4 buffered to pH 3 using H3PO4 (3+7, v/v). The photodiode array detector was used to test the purity of the peaks, and the chromatograms were extracted at 240 nm. The method was validated, and validation acceptance criteria were met in all cases. The robust method was successfully applied to the determination of granisetron and preservatives, as well as their degradation products in different batches of granisetron oral drops and solutions. The method proved to be sensitive for determination down to 0.04% (w/w) of granisetron degradation product relative to granisetron and 0.03% (w/w) 4-hydroxybenzoic acid relative to total parabens.

  12. Optimization of Robust HPLC Method for Quantitation of Ambroxol Hydrochloride and Roxithromycin Using a DoE Approach.

    PubMed

    Patel, Rashmin B; Patel, Nilay M; Patel, Mrunali R; Solanki, Ajay B

    2017-03-01

    The aim of this work was to develop and optimize a robust HPLC method for the separation and quantitation of ambroxol hydrochloride and roxithromycin utilizing Design of Experiment (DoE) approach. The Plackett-Burman design was used to assess the impact of independent variables (concentration of organic phase, mobile phase pH, flow rate and column temperature) on peak resolution, USP tailing and number of plates. A central composite design was utilized to evaluate the main, interaction, and quadratic effects of independent variables on the selected dependent variables. The optimized HPLC method was validated based on ICH Q2R1 guideline and was used to separate and quantify ambroxol hydrochloride and roxithromycin in tablet formulations. The findings showed that DoE approach could be effectively applied to optimize a robust HPLC method for quantification of ambroxol hydrochloride and roxithromycin in tablet formulations. Statistical comparison between results of proposed and reported HPLC method revealed no significant difference; indicating the ability of proposed HPLC method for analysis of ambroxol hydrochloride and roxithromycin in pharmaceutical formulations. © The Author 2016. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.

  13. Stability indicating validated HPLC method for quantification of levothyroxine with eight degradation peaks in the presence of excipients.

    PubMed

    Shah, R B; Bryant, A; Collier, J; Habib, M J; Khan, M A

    2008-08-06

    A simple, sensitive, accurate, and robust stability indicating analytical method is presented for identification, separation, and quantitation of l-thyroxine and eight degradation impurities with an internal standard. The method was used in the presence of commonly used formulation excipients such as butylated hydroxyanisole, povidone, crospovidone, croscarmellose sodium, mannitol, sucrose, acacia, lactose monohydrate, confectionary sugar, microcrystalline cellulose, sodium laurel sulfate, magnesium stearate, talc, and silicon dioxide. The two active thyroid hormones: 3,3',5,5'-tetra-iodo-l-thyronine (l-thyroxine-T4) and 3,3',5-tri-iodo-l-thyronine (T3) and degradation products including di-iodothyronine (T2), thyronine (T0), tyrosine (Tyr), di-iodotyrosine (DIT), mono-iodotyrosine (MIT), 3,3',5,5'-tetra-iodothyroacetic acid (T4AA) and 3,3',5-tri-iodothyroacetic acid (T3AA) were assayed by the current method. The separation of l-thyroxine and eight metabolites along with theophylline (internal standard) was achieved using a C18 column (25 degrees C) with a mobile phase of trifluoroacetic acid (0.1%, v/v, pH 3)-acetonitrile in gradient elution at 0.8 ml/min at 223 nm. The sample diluent was 0.01 M methanolic NaOH. Method was validated according to FDA, USP, and ICH guidelines for inter-day accuracy, precision, and robustness after checking performance with system suitability. Tyr (4.97 min), theophylline (9.09 min), MIT (9.55 min), DIT (11.37 min), T0 (11.63 min), T2 (14.47 min), T3 (16.29 min), T4 (17.60 min), T3AA (22.71 min), and T4AA (24.83 min) separated in a single chromatographic run. Linear relationship (r2>0.99) was observed between the peak area ratio and the concentrations for all of the compounds within the range of 2-20 microg/ml. The total time for analysis, equilibration and recovery was 40 min. The method was shown to separate well from commonly employed formulation excipients. Accuracy ranged from 95 to 105% for T4 and 90 to 110% for all other compounds. Precision was <2% for all the compounds. The method was found to be robust with minor changes in injection volume, flow rate, column temperature, and gradient ratio. Validation results indicated that the method shows satisfactory linearity, precision, accuracy, and ruggedness and also stress degradation studies indicated that the method can be used as stability indicating method for l-thyroxine in the presence of excipients.

  14. Medicinal cannabis: Principal cannabinoids concentration and their stability evaluated by a high performance liquid chromatography coupled to diode array and quadrupole time of flight mass spectrometry method.

    PubMed

    Citti, Cinzia; Ciccarella, Giuseppe; Braghiroli, Daniela; Parenti, Carlo; Vandelli, Maria Angela; Cannazza, Giuseppe

    2016-09-05

    In the last few years, there has been a boost in the use of cannabis-based extracts for medicinal purposes, although their preparation procedure has not been standardized but rather decided by the individual pharmacists. The present work describes the development of a simple and rapid high performance liquid chromatography method with UV detection (HPLC-UV) for the qualitative and quantitative determination of the principal cannabinoids (CBD-A, CBD, CBN, THC and THC-A) that could be applied to all cannabis-based medicinal extracts (CMEs) and easily performed by a pharmacist. In order to evaluate the identity and purity of the analytes, a high-resolution mass spectrometry (HPLC-ESI-QTOF) analysis was also carried out. Full method validation has been performed in terms of specificity, selectivity, linearity, recovery, dilution integrity and thermal stability. Moreover, the influence of the solvent (ethyl alcohol and olive oil) was evaluated on cannabinoids degradation rate. An alternative extraction method has then been proposed in order to preserve cannabis monoterpene component in final CMEs. Copyright © 2016 Elsevier B.V. All rights reserved.

  15. HPLC & NMR-based forced degradation studies of ifosfamide: The potential of NMR in stability studies.

    PubMed

    Salman, D; Peron, J-M R; Goronga, T; Barton, S; Swinden, J; Nabhani-Gebara, S

    2016-03-01

    The aim of this study is to conduct a forced degradation study on ifosfamide under several stress conditions to investigate the robustness of the developed HPLC method. It also aims to provide further insight into the stability of ifosfamide and its degradation profile using both HPLC and NMR. Ifosfamide solutions (20mg/mL; n=15, 20mL) were stressed in triplicate by heating (70°C), under acidic (pH 1 & 4) and alkaline (pH 10 & 12) conditions. Samples were analysed periodically using HPLC and FT-NMR. Ifosfamide was most stable under weakly acidic conditions (pH 4). NMR results suggested that the mechanism of ifosfamide degradation involves the cleavage of the PN bond. For all stress conditions, HPLC was not able to detect ifosfamide degradation products that were detected by NMR. These results suggest that the developed HPLC method for ifosfamide did not detect the degradation products shown by NMR. It is possible that degradation products co-elute with ifosfamide, do not elute altogether or are not amenable to the detection method employed. Therefore, investigation of ifosfamide stability requires additional techniques that do not suffer from the aforementioned shortcomings. Copyright © 2015 Académie Nationale de Pharmacie. Published by Elsevier Masson SAS. All rights reserved.

  16. A novel HPLC-MS/MS method for the simultaneous determination of astemizole and its major metabolite in dog or monkey plasma and application to pharmacokinetics.

    PubMed

    Back, Hyun-moon; Lee, Jong-Hwa; Chae, Jung-woo; Song, Byungjeong; Seo, Joung-Wook; Yun, Hwi-yeol; Kwon, Kwang-il

    2015-10-10

    Astemizole (AST), a second-generation antihistamine, is metabolized to desmethyl astemizole (DEA), and although it has been removed from the market for inducing QT interval prolongation, it has reemerged as a potential anticancer and antimalarial agent. This report describes a novel high-performance liquid chromatography-tandem mass spectrometry (HPLC-MS/MS) method for simultaneously determining the concentrations of AST and DEA in beagle dog and cynomolgus monkey plasma with simple preparation method and short retention time. Prior to HPLC analyses, the plasma samples were extracted with simple liquid-liquid extraction method. The isocratic mobile phase was 0.025% trifluoroacetic acid (TFA dissolved in acetonitrile) and 20 mM ammonium acetate (94:6) at a flow rate of 0.25 mL/min and diphenhydramine used as internal standard. In MS/MS analyses, precursor ions of the analytes were optimized as protonated molecular ions: [M+H](+). The lower limit of quantification of astemizole was 2.5 ng/mL in both species and desmethyl astemizole were 7.5 ng/mL and 10 ng/mL in dog and monkey plasma, respectively. The accuracy, precision, and stability of the method were in accordance with FDA guidelines for the validation of bioanalytical methods. Finally this validated method was successfully applied to a pharmacokinetic study in dogs and monkeys after oral administration of 10 mg/kg AST. Copyright © 2015 Elsevier B.V. All rights reserved.

  17. HPLC and UPLC methods for the determination of zearalenone in noodles, cereal snacks and infant formula.

    PubMed

    Ok, Hyun Ee; Choi, Sung-Wook; Kim, Meehye; Chun, Hyang Sook

    2014-11-15

    High-performance liquid chromatography (HPLC) and ultra-performance liquid chromatography (UPLC) were compared to validate a method for determination of zearalenone (ZON) in noodles, cereal snacks, and infant formulas. The limits of detection and quantification in HPLC and UPLC were found to be 4.0 and 13.0 μg kg(-1) and 2.5 and 8.3 μg kg(-1), respectively. The average recoveries of ZON by HPLC and UPLC ranged from 79.1% to 105.3% and from 85.1% to 114.5%, respectively. The measurement uncertainties of the two methods for ZON determination were within the maximum standard uncertainty. The two methods showed that the levels of ZON in 163 naturally contaminated samples ranged from 4.3 to 8.3 μg kg(-1) by HPLC and 3.1 to 17.6 μg kg(-1) by UPLC. These findings indicate that either method is suitable for the determination of ZON in noodles, cereal snacks, and infant formulas, but UPLC gives faster results with better sensitivity. Copyright © 2014 Elsevier Ltd. All rights reserved.

  18. Study on the Multi-marker Components Quantitative HPLC Fingerprint of the Compound Chinese Medicine Wuwei Changyanning Granule

    PubMed Central

    Yang, Xian; Yang, Shui-Ping; Zhang, Xue; Yu, Xiao-Dong; He, Qi-Yi; Wang, Bo-Chu

    2014-01-01

    The aim of this paper is to develop a rapid and highly sensitive quantitative HPLC fingerprint method with multiple indicators by using the Compound Chinese Medicine Wuwei Changyanning granule and 5 herbs in the prescription. The quantitative fingerprint chromatogram with multiple indicators was investigated. і)6 compositions included rutin, gallic acid, chlorogenic acid, atractylenolide Ⅰ, pachymic acid and apigenin, which originated from 5 herbs respectively, were selected as quantitative compositions, and their contents were determined using HPLC from 11 batches granules and the corresponding 5 medicinal materials. ⅱ) The precision, stability and repeatability of fingerprinting were investigated. In addition, common peaks number, the percentage of non-common peaks and similarity were also studied. Among them, 21 common peaks in the granule could find the source of peaks from the 5 herbs, among of 10 peaks from Niuerfeng, 9 peaks from Laliao, 3 peaks from Baishu, 3 peaks from Fuling and 5 peaks from Guanghuoxiang. The results showed that the identification method of fingerprinting was reliable. PMID:25587307

  19. Development and Validation of High Performance Liquid Chromatography Method for Determination Atorvastatin in Tablet

    NASA Astrophysics Data System (ADS)

    Yugatama, A.; Rohmani, S.; Dewangga, A.

    2018-03-01

    Atorvastatin is the primary choice for dyslipidemia treatment. Due to patent expiration of atorvastatin, the pharmaceutical industry makes copy of the drug. Therefore, the development methods for tablet quality tests involving atorvastatin concentration on tablets needs to be performed. The purpose of this research was to develop and validate the simple atorvastatin tablet analytical method by HPLC. HPLC system used in this experiment consisted of column Cosmosil C18 (150 x 4,6 mm, 5 µm) as the stationary reverse phase chomatography, a mixture of methanol-water at pH 3 (80:20 v/v) as the mobile phase, flow rate of 1 mL/min, and UV detector at wavelength of 245 nm. Validation methods were including: selectivity, linearity, accuracy, precision, limit of detection (LOD), and limit of quantitation (LOQ). The results of this study indicate that the developed method had good validation including selectivity, linearity, accuracy, precision, LOD, and LOQ for analysis of atorvastatin tablet content. LOD and LOQ were 0.2 and 0.7 ng/mL, and the linearity range were 20 - 120 ng/mL.

  20. Cholesterol concentrations in lipoprotein fractions separated by anion-exchange-high-performance liquid chromatography in healthy dogs and dogs with hypercholesterolemia.

    PubMed

    Oda, Hitomi; Mori, Akihiro; Hirowatari, Yuji; Takoura, Toshie; Manita, Daisuke; Takahashi, Tomoya; Shono, Saori; Onozawa, Eri; Mizutani, Hisashi; Miki, Yohei; Itabashi, Yukiko; Sako, Toshinori

    2017-10-01

    Anion-exchange (AEX)-high-performance liquid chromatography (HPLC) for measurement of cholesterol can be used to separate serum lipoproteins (high-density lipoprotein (HDL); low-density lipoprotein (LDL); intermediate-density lipoprotein (IDL); very-low-density lipoprotein (VLDL)) in humans. However, AEX-HPLC has not been applied in veterinary practice. We had three objectives: (i) the validation of AEX-HPLC methods including the correlation of serum cholesterol concentration in lipoprotein fraction measured by AEX-HPLC and gel permeation-HPLC (GP-HPLC) in healthy dogs and those with hypercholesterolemia was investigated; (ii) the reference intervals of lipoprotein fractions measured by AEX-HPLC from healthy dogs (n=40) was established; (iii) lipoprotein fractions from the serum of healthy dogs (n=12) and dogs with hypercholesterolemia (n=23) were compared. Analytic reproducibility and precision of AEX-HPLC were acceptable. Positive correlation between serum concentrations of total cholesterol (Total-Chol), HDL cholesterol (HDL-Chol), LDL cholesterol (LDL-Chol)+IDL cholesterol (IDL-Chol), and VLDL cholesterol (VLDL-Chol) was noted for AEX-HPLC and GP-HPLC in healthy dogs and dogs with hypercholesterolemia. Reference intervals measured by AEX-HPLC for serum concentrations of Total-Chol, HDL-Chol, and LDL-Chol were determined to be 2.97-9.32, 2.79-6.57, 0.16-3.28mmol/L (2.5-97.5% interval), respectively. Furthermore, there was significant difference in lipoprotein profiles between healthy and dogs with hypercholesterolemia. These results suggest that AEX-HPLC can be used to evaluate lipoprotein profiles in dogs and could be a new useful indicator of hyperlipidemia in dogs. Copyright © 2017 Elsevier Ltd. All rights reserved.

  1. Simultaneous determination of some water-soluble vitamins and preservatives in multivitamin syrup by validated stability-indicating high-performance liquid chromatography method.

    PubMed

    Vidović, Stojanka; Stojanović, Biljana; Veljković, Jelena; Prazić-Arsić, Ljiljana; Roglić, Goran; Manojlović, Dragan

    2008-08-22

    HPLC stability-indicating method has been developed for the simultaneous determination of some water-soluble vitamins (ascorbic acid, thiamine hydrochloride, riboflavin-5'-phosphate sodium, pyridoxine hydrochloride, nicotinamide, D(+)-panthenol) and two preservatives (methylparaben and sodium benzoate) in multivitamin syrup preparation. Water-soluble vitamins, preservatives and their degradants were separated on Zorbax SB-Aq (C(18)) (250 mm x 4.6 mm, 5 microm) column at an ambient temperature. Combined isocratic and gradient elution was performed with a mobile phase consisting of 0.0125 M hexane-1-sulfonic acid sodium salt in 0.1% (m/v) o-phosphoric acid, pH 2.4-2.5 (solvent A) and acetonitrile (solvent B) at the flow-rate 1 ml min(-1). Starting with solvent A an isocratic elution was performed for 15 min, then the composition was changed to 85% of A and 15% of B during the next 20 min and it was constant for 5 min, then the composition was changed to 70% of A and 30% of B during next 15 min and it was constant for 5 min and finally was changed to 100% of A as at the beginning of the elution. Detection was performed with diode array detector at 210, 230 and 254 nm. Multivitamin syrup preparation was subjected to stress testing (forced degradation) in order to demonstrate that degradants from the vitamins, preservatives and/or product excipients do not interfere with the quantification of vitamins and preservatives. Typical validation characteristics: selectivity, accuracy, precision, linearity, range, limit of quantification and limit of detection were evaluated for vitamins and preservatives.

  2. [Comparison between colorimetry and HPLC on the stability test of roxithromycin].

    PubMed

    Wei, Z P; Mao, S R; Bi, D Z

    2000-11-01

    To compare the stability of roxithromycin in solutions of different pH. Roxithromycin solutions of different pH were prepared with water, simulate intestinal fluid (SIF) and simulate gastric fluid (SGF) shown to be the stability of these solutions were tested by colorimetry and HPLC. Roxithromycin was stable in water, SGF and SIF determined by colorimetry. However, it was found to be stable only in water and SIF but unstable in SGF as determined by HPLC. Roxithromycin is unstable in acidic medium like SGF. The metabolite of roxithromycin showed unfavorable interference on the assay of roxithromycin when colorimetry was used. Colorimetry can not be used for the determination and assay of roxithromycin in acidic solution like SGF.

  3. Development of a titanium dioxide-coated microfluidic-based photocatalyst-assisted reduction device to couple high-performance liquid chromatography with inductively coupled plasma-mass spectrometry for determination of inorganic selenium species.

    PubMed

    Shih, Tsung-Ting; Lin, Cheng-Hsing; Hsu, I-Hsiang; Chen, Jian-Yi; Sun, Yuh-Chang

    2013-11-05

    We developed a selective and sensitive hyphenated system employing a microfluidic-based vapor generation (VG) system in conjunction with high-performance liquid chromatography (HPLC) separation and inductively coupled plasma-mass spectrometry (ICPMS) detection for the determination of trace inorganic selenium (Se) species. The VG system exploited poly(methyl methacrylate) (PMMA) substrates of high optical quality to fabricate a microfluidic-based photocatalyst-assisted reduction device (microfluidic-based PCARD). Moreover, to reduce the consumption of photocatalysts during analytical procedures, a microfluidic-based PCARD coated with titanium dioxide nanoparticles (nano-TiO2) was employed to avoid consecutive loading. Notably, to simplify the coating procedure and improve the stability of the coating materials, a dynamic coating method was utilized. Under the optimized conditions for the selenicals of interest, the online HPLC/TiO2-coated microfluidic-based PCARD/ICPMS system enabled us to achieve detection limits (based on 3σ) of 0.043 and 0.042 μg L(-1) for Se(IV) and Se(VI), respectively. Both Se(IV) and Se(VI) could be efficiently vaporized within 15 s, while a series of validation experiments indicated that our proposed method could be satisfactorily applied to the determination of inorganic Se species in the environmental water samples.

  4. Quantitative and qualitative analysis of the novel antitumor 1,3,4-oxadiazole derivative (GLB) and its metabolites using HPLC-UV and UPLC-QTOF-MS

    PubMed Central

    Li, Pu; Wang, Xin; Li, Jian; Meng, Zhi-Yun; Li, Shu-Chun; Li, Zhong-Jun; Lu, Ying-Yuan; Ren, Hong; Lou, Ya-Qing; Lu, Chuang; Dou, Gui-Fang; Zhang, Guo-Liang

    2015-01-01

    Fructose-based 3-acetyl-2,3-dihydro-1,3,4-oxadiazole (GLB) is a novel antitumor agent and belongs to glycosylated spiro-heterocyclic oxadiazole scaffold derivative. This research first reported a simple, specific, sensitive and stable high performance liquid chromatography -ultraviolet detector (HPLC-UV) method for the quantitative determination of GLB in plasma. In this method, the chromatographic separation was achieved with a reversed phase C18 column. The calibration curve for GLB was linear at 300 nm. The lower limit of quantification was 10 ng/mL. The precision, accuracy and stability of the method were validated adequately. This method was successfully applied to the pharmacokinetic study in rats for detection of GLB after oral administration. Moreover, the structures of parent compound GLB and its two major metabolites M1 and M2 were identified in plasma using an ultra performance liquid chromatography- electrospray ionization-quadrupole-time of flight- mass spectrometry (UPLC-ESI-QTOF-MS) method. Our results indicated that the di-hydroxylation (M1) and hydroxylation (M2) of GLB are the major metabolites. In conclusion, the present study provided valuable information on an analytical method for the determination of GLB and its metabolites in rats, can be used to support further developing of this antitumor agent. PMID:26148672

  5. Quantitative determination and classification of energy drinks using near-infrared spectroscopy.

    PubMed

    Rácz, Anita; Héberger, Károly; Fodor, Marietta

    2016-09-01

    Almost a hundred commercially available energy drink samples from Hungary, Slovakia, and Greece were collected for the quantitative determination of their caffeine and sugar content with FT-NIR spectroscopy and high-performance liquid chromatography (HPLC). Calibration models were built with partial least-squares regression (PLSR). An HPLC-UV method was used to measure the reference values for caffeine content, while sugar contents were measured with the Schoorl method. Both the nominal sugar content (as indicated on the cans) and the measured sugar concentration were used as references. Although the Schoorl method has larger error and bias, appropriate models could be developed using both references. The validation of the models was based on sevenfold cross-validation and external validation. FT-NIR analysis is a good candidate to replace the HPLC-UV method, because it is much cheaper than any chromatographic method, while it is also more time-efficient. The combination of FT-NIR with multidimensional chemometric techniques like PLSR can be a good option for the detection of low caffeine concentrations in energy drinks. Moreover, three types of energy drinks that contain (i) taurine, (ii) arginine, and (iii) none of these two components were classified correctly using principal component analysis and linear discriminant analysis. Such classifications are important for the detection of adulterated samples and for quality control, as well. In this case, more than a hundred samples were used for the evaluation. The classification was validated with cross-validation and several randomization tests (X-scrambling). Graphical Abstract The way of energy drinks from cans to appropriate chemometric models.

  6. A fast and validated method for the determination of malondialdehyde in fish liver using high-performance liquid chromatography with a photodiode array detector.

    PubMed

    Faizan, Mohammad; Esatbeyoglu, Tuba; Bayram, Banu; Rimbach, Gerald

    2014-04-01

    Malondialdehyde (MDA) is a biomarker of lipid peroxidation and is present in foods and biological samples such as plasma. A high-performance liquid chromatography (HPLC) method was applied to determine MDA in fish liver samples after derivatization with 2,4-dinitrophenylhydrazine (DNPH) using a ODS2 column (10 cm × 4.6 mm, 3 μm) and a photodiode array detector. The mobile phase consisted of 0.2% acetic acid (v/v) in distilled water and acetonitrile (42:58, v/v). The present method was validated in terms of linearity, lower limit of quantification, lower limit of detection, precision, accuracy, recovery, and stability of MDA according to U.S. Food and Drug Administration (FDA) guidelines. The limit of quantification of MDA was 0.39 μmol/L, which is comparable to other methods. The recovery of the spiked MDA liver samples was in the range of 92.4% to 104.2%. This newly modified HPLC method is specific, sensitive, and accurate and allows the analysis of MDA within 4 min in fish liver but also in other tissues and plasma. © 2014 Institute of Food Technologists®

  7. Development and Validation of a Stability-Indicating HPLC Method for Imidapril and Its Degradation Products Using a Design of Experiment (DoE) Approach.

    PubMed

    Arumugam, Abiramasundari; Joshi, Amita; Vasu, Kamala K

    2017-11-01

    The present work focused on the application of design of experiment (DoE) principles to the development and optimization of a stability-indicating method (SIM) for the drug imidapril hydrochloride and its degradation products (DPs). The resolution of peaks for the DPs and their drug in a SIM can be influenced by many factors. The factors studied here were pH, gradient time, organic modifier, flow rate, molar concentration of the buffer, and wavelength, with the aid of a Plackett-Burman design. Results from the Plackett-Burman study conspicuously showed influence of two factors, pH and gradient time, on the analyzed response, particularly, the resolution of the closely eluting DPs (DP-5 and DP-6) and the retention time of the last peak. Optimization of the multiresponse processes was achieved through Derringer's desirability function with the assistance of a full factorial design. Separation was achieved using a C18 Phenomenex Luna column (250 × 4.6 mm id, 5 µm particle size) at a flow rate of 0.8 mL/min at 210 nm. The optimized mobile phase composition was ammonium-acetate buffer (pH 5) in pump A and acetonitrile-methanol (in equal ratio) in pump B with a run time of 40 min using a gradient method.

  8. A Rapid Novel HPLC Method for Estimation of Eight Related Compounds in Azilsartan Kamedoxomil and Identification of Degradation Compounds by Using LC-MS.

    PubMed

    Sreenivasulu, J; Venkata Ramana, P; Sampath Kumar Reddy, G; Nagaraju, Ch V S; Thirumalai Rajan, S; Eswaraiah, S

    2015-10-01

    A novel, rapid, specific and stability-indicating reverse-phase high-performance liquid chromatography method was developed for the quantitative determination of related compounds, obtained from two different synthetic routes and degradation products of Azilsartan kamedoxomil (AZL). The method was developed by using a YMC-Pack pro C18 (150 × 4.6 mm, 3 µm) column with a mobile phase containing a gradient mobile phase combination. The eluted compounds were measured at wavelength 220 nm. The developed method run time was 25 min, within which AZL and its eight impurities were well separated with minimum 3.0 resolution. The drug substance was subjected to stress conditions of hydrolysis (acid, base and water), oxidation, photolysis, sunlight, 75% relative humidity and thermal degradation as per International Conference on Harmonization (ICH) prescribed stress conditions to ascertain the stability-indicating power of the method. Significant degradation was observed during acid, base, peroxide, water hydrolysis and 75% relative humidity studies. The mass balance of AZL was close to 100% in all the stress condition. The developed method was validated as per the ICH guidelines with respect to specificity, linearity, limit of detection, limit of quantification, accuracy, precision and robustness. © The Author 2015. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.

  9. Application of solid-phase microextraction in the investigation of protein binding of pharmaceuticals.

    PubMed

    Theodoridis, Georgios

    2006-01-18

    Protein-drug interactions of seven common pharmaceuticals were studied using solid-phase microextraction (SPME). SPME can be used in such investigations on the condition that no analyte depletion occurs. In multi-compartment systems (e.g. a proteinaceous matrix) only the free portion of the analyte is able to partition into the SPME fiber. In addition if no sample depletion occurs, the bound drug-free drug equilibria are not disturbed. In the present study seven pharmaceuticals (quinine, quinidine, naproxen, ciprofloxacin, haloperidol, paclitaxel and nortriptyline) were assayed by SPME. For quantitative purposes SPME was validated first in the absence of proteins. Calibration curves were constructed for each drug by HPLC-fluorescence and HPLC-UV analysis. SPME was combined to HPLC off-line, desorption occurring in HPLC inserts filled with 200 microL methanol. Binding of each drug to human serum albumin was studied independently. Experimental results were in agreement with literature data and ultrafiltration experiments, indicating the feasibility of the method for such bioanalytical purposes.

  10. New approaches with two cyano columns to the separation of acetaminophen, phenylephrine, chlorpheniramine and related compounds.

    PubMed

    Olmo, B; García, A; Marín, A; Barbas, C

    2005-03-25

    The development of new pharmaceutical forms with classical active compounds generates new analytical problems. That is the case of sugar-free sachets of cough-cold products containing acetaminophen, phenylephrine hydrochloride and chlorpheniramine maleate. Two cyanopropyl stationary phases have been employed to tackle the problem. The Discovery cyanopropyl (SUPELCO) column permitted the separation of the three actives, maleate and excipients (mainly saccharine and orange flavour) with a constant proportion of aqueous/ organic solvent (95:5, v/v) and a pH gradient from 7.5 to 2. The run lasted 14 min. This technique avoids many problems related to baseline shifts with classical organic solvent gradients and opens great possibilities to modify selectivity not generally used in reversed phase HPLC. On the other hand, the Agilent Zorbax SB-CN column with a different retention profile permitted us to separate not only the three actives and the excipients but also the three known related compounds: 4-aminophenol, 4-chloracetanilide and 4-nitrophenol in an isocratic method with a run time under 30 min. This method was validated following ICH guidelines and validation parameters showed that it could be employed as stability-indicating method for this pharmaceutical form.

  11. Rifaximin Stability: A Look at UV, IR, HPLC, and Turbidimetry Methods.

    PubMed

    Kogawa, Ana Carolina; Salgado, Hérida Regina Nunes

    2018-03-01

    The study of the stability of medicines is mandated by the International Conference on Harmonization and the World Health Organization. Rifaximin, an antimicrobial marketed in the form of tablets, has no record of stability studies. Thus, the objective of the present work was to investigate the behavior and stability of rifaximin tablets for 6 months under simultaneous conditions of temperature and humidity by UV, IR, HPLC, and turbidimetry techniques. After 6 months of stability study, rifaximin tablets were shown to obey zero-order kinetics when analyzed by physicochemical methods and second-order kinetics when analyzed by a microbiological method. However, the UV method was not suitable for the evaluation of rifaximin. IR, HPLC, and turbidimetry methods can already be used to evaluate the stability of rifaximin tablets. It is important to analyze products with more than one type of method before releasing results mainly in the case of antimicrobial products in which the association of physicochemical and microbiological techniques must be a rule. Rifaximin tablets can be considered stable after 6 months under conditions of 40 ± 2°C and 75 ± 5% relative humidity.

  12. Simultaneous separation and determination of 15 organic UV filters in sunscreen cosmetics by HPLC-ESI-MS/MS.

    PubMed

    Meng, X; Ma, Q; Bai, H; Wang, Z; Han, C; Wang, C

    2017-08-01

    A comprehensive methodology for the simultaneous determination of 15 multiclass organic UV filters in sunscreen cosmetics was developed using high-performance liquid chromatography coupled with electrospray ionization tandem mass spectrometry (HPLC-ESI-MS/MS). Sunscreen cosmetics of various matrices, such as toning lotion, emulsion, cream and lipstick, were analysed. Ultrasound-assisted extraction (UAE) was utilized as the extraction technique for sample preparation. The 15 UV filters were chromatographically separated by two groups of mobile phase system on an XBridge C 18 analytical column (150 × 2.1 mm I.D., 3.5 μm particle size) and quantified using HPLC-ESI-MS/MS. The quantitation was performed using the external calibration method. The established method was validated in terms of linearity, sensitivity, specificity, accuracy, stability, intraday and interday precisions, recovery and matrix effect. The method was also applied for the determination of UV filters in commercial sunscreen cosmetics. The experimental results demonstrated that the developed method was accurate, rapid and sensitive and can be used for the analytical control of sunscreen cosmetics. © 2016 Society of Cosmetic Scientists and the Société Française de Cosmétologie.

  13. Chromatographic methods for determination of S-substituted cysteine derivatives--a comparative study.

    PubMed

    Kubec, Roman; Dadáková, Eva

    2009-10-09

    A novel HPLC method for determination of a wide variety of S-substituted cysteine derivatives in Allium species has been developed and validated. This method allows simultaneous separation and quantification of S-alk(en)ylcysteine S-oxides, gamma-glutamyl-S-alk(en)ylcysteines and gamma-glutamyl-S-alk(en)ylcysteine S-oxides in a single run. The procedure is based on extraction of these amino acids and dipeptides by methanol, their derivatization by dansyl chloride and subsequent separation by reversed phase HPLC. The main advantages of the new method are simplicity, excellent stability of derivatives, high sensitivity, specificity and the ability to simultaneously analyze the whole range of S-substituted cysteine derivatives. This method was critically compared with other chromatographic procedures used for quantification of S-substituted cysteine derivatives, namely with two other HPLC methods (derivatization by o-phthaldialdehyde/tert-butylthiol and fluorenylmethyl chloroformate), and with determination by gas chromatography or capillary electrophoresis. Major advantages and drawbacks of these analytical procedures are discussed. Employing these various chromatographic methods, the content and relative proportions of individual S-substituted cysteine derivatives were determined in four most frequently consumed alliaceous vegetables (garlic, onion, shallot, and leek).

  14. Stability study of the anticonvulsant enaminone (E118) using HPLC and LC-MS.

    PubMed

    Abdel-Hamid, Mohammed E; Edafiogho, Ivan O; Hamza, Huda M

    2002-01-01

    The stability of the new chemical synthetic enaminone derivative (E118) was investigated using a stability-indicating high-performance liquid chromatography (HPLC) procedure. The examined samples were analyzed using a chiral HSA column and a mobile phase (pH 7.5) containing n-octanoic acid (5 mM), isopropyl alcohol and 100 mM disodium hydrogen phosphate solution (1:9 v/v) at a flow rate of 1 ml min(-1). The developed method was specific, accurate and reproducible. The HPLC chromatograms exhibited well-resolved peaks of E118 and the degradation products at retention times <5 min. The stability of E118 was performed in 0.1 M hydrochloric acid, 0.1 M sodium hydroxide, water/ethanol (1:1) and phosphate buffer (pH approximately 7.5) solutions. E118 was found to undergo fast hydrolysis in 0.1 M hydrochloric acid solution. The decomposition of E118 followed first order kinetics under the experimental conditions. The results confirmed that protonation of the enaminone system in the molecule enhanced the hydrolysis of E118 at degradation rate constant of 0.049 min(-1) and degradation half-life of 14.1 min at 25 degrees C. However, E118 was significantly stable in 0.1 M sodium hydroxide, physiological phosphate buffer (pH 7.5) and ethanol/water (1:1) solutions. The degradation rate constants and degradation half-lives were in the ranges 0.0023-0.0086 h(-1) and 80.6-150.6 h, respectively. Analysis of the acid-induced degraded solution of E118 by liquid chromatography-mass spectrometry (LC-MS) revealed at least two degradation products of E118 at m/z 213.1 and 113.1, respectively.

  15. Stability of gabapentin in extemporaneously compounded oral suspensions.

    PubMed

    Friciu, Mihaela; Roullin, V Gaëlle; Leclair, Grégoire

    2017-01-01

    This study reports the stability of extemporaneously prepared gabapentin oral suspensions prepared at 100 mg/mL from bulk drug and capsules in either Oral Mix or Oral Mix SF suspending vehicles. Suspensions were packaged in amber plastic bottles and amber plastic syringes at 25°C / 60%RH for up to 90 days. Throughout the study period, the following tests were performed to evaluate the stability of the preparations: organoleptic inspection to detect homogeneity, color or odor changes; pH measurements; and gabapentin assay using a stability-indicating HPLC-UV method. As crystallization was observed at 5°C, storage at this temperature condition is not recommended. All preparations stored at 25°C / 60%RH remained stable for the whole study duration of 90 days.

  16. Method optimization and quality assurance in speciation analysis using high performance liquid chromatography with detection by inductively coupled plasma mass spectrometry

    NASA Astrophysics Data System (ADS)

    Larsen, Erik H.

    1998-02-01

    Achievement of optimum selectivity, sensitivity and robustness in speciation analysis using high performance liquid chromatography (HPLC) with inductively coupled mass spectrometry (ICP-MS) detection requires that each instrumental component is selected and optimized with a view to the ideal operating characteristics of the entire hyphenated system. An isocratic HPLC system, which employs an aqueous mobile phase with organic buffer constituents, is well suited for introduction into the ICP-MS because of the stability of the detector response and high degree of analyte sensitivity attained. Anion and cation exchange HPLC systems, which meet these requirements, were used for the seperation of selenium and arsenic species in crude extracts of biological samples. Furthermore, the signal-to-noise ratios obtained for these incompletely ionized elements in the argon ICP were further enhanced by a factor of four by continously introducing carbon as methanol via the mobile phase into the ICP. Sources of error in the HPLC system (column overload), in the sample introduction system (memory by organic solvents) and in the ICP-MS (spectroscopic interferences) and their prevention are also discussed. The optimized anion and cation exchange HPLC-ICP-MS systems were used for arsenic speciation in contaminated ground water and in an in-house shrimp reference sample. For the purpose of verification, HPLC coupled with tandem mass spectrometry with electrospray ionization was additionally used for arsenic speciation in the shrimp sample. With this analytical technique the HPLC retention time in combination with mass analysis of the molecular ions and their collision-induced fragments provide almost conclusive evidence of the identity of the analyte species. The speciation methods are validated by establishing a mass balance of the analytes in each fraction of the extraction procedure, by recovery of spikes and by employing and comparing independent techniques. The urgent need for reference materials certified for elemental species is stressed.

  17. [Spectrophotometric and HPLC evaluation of ceftazidime stability].

    PubMed

    Palade, B; Cioroiu, B; Lazăr, Doina; Corciovă, Andreia; Lazăr, M I

    2010-01-01

    In this paper we followed up the stability of ceftazidime, raw material used in drug industry. Matherials and methods: We used three spectrophotometric methods based on ceftazidime property to form complexes with p-chloranilic acid (ac. p-CA), 3-methylbenzothiazolin-2-on hydrazone (MBTH) and N-(1-naphtil) etilendiamine (NEDA) and a chromatographic method (HPLC). Our results revealed that the substances analyzed maintained minimum content allowable.

  18. Development and validation of chromatographic methods (HPLC and GC) for the determination of the active components (benzocaine, tyrothricin and menthol) of a pharmaceutical preparation.

    PubMed

    Ortiz-Boyer, F; Tena, M T; Luque de Castro, M D; Valcárcel, M

    1995-10-01

    Methods are reported for the determination of tyrothricin and benzocaine by HPLC and menthol by GC in the analysis of throat lozenges (tablets) containing all three compounds. After optimization of the variables involved in both HPLC and GC the methods have been characterized and validated according to the guidelines of the Spanish Pharmacopoeia, and applied to both the monitoring of the manufacturing process and the quality control of the final product.

  19. Online identification of chlorogenic acids, sesquiterpene lactones, and flavonoids in the Brazilian arnica Lychnophora ericoides Mart. (Asteraceae) leaves by HPLC-DAD-MS and HPLC-DAD-MS/MS and a validated HPLC-DAD method for their simultaneous analysis.

    PubMed

    Gobbo-Neto, Leonardo; Lopes, Norberto P

    2008-02-27

    Lychnophora ericoides Mart. (Asteraceae, Vernonieae) is a plant, endemic to Brazil, with occurrence restricted to the "cerrado" biome. Traditional medicine employs alcoholic and aqueous-alcoholic preparations of leaves from this species for the treatment of wounds, inflammation, and pain. Furthermore, leaves of L. ericoides are also widely used as flavorings for the Brazilian traditional spirit "cachaça". A method has been developed for the extraction and HPLC-DAD analysis of the secondary metabolites of L. ericoides leaves. This analytical method was validated with 11 secondary metabolites chosen to represent the different classes and polarities of secondary metabolites occurring in L. ericoides leaves, and good responses were obtained for each validation parameter analyzed. The same HPLC analytical method was also employed for online secondary metabolite identification by HPLC-DAD-MS and HPLC-DAD-MS/MS, leading to the identification of di- C-glucosylflavones, coumaroylglucosylflavonols, flavone, flavanones, flavonols, chalcones, goyazensolide, and eremantholide-type sesquiterpene lactones and positional isomeric series of chlorogenic acids possessing caffeic and/or ferulic moieties. Among the 52 chromatographic peaks observed, 36 were fully identified and 8 were attributed to compounds belonging to series of caffeoylferuloylquinic and diferuloylquinic acids that could not be individualized from each other.

  20. A stability-study of expired ampoules manufactured more than 40 years ago.

    PubMed

    Zilker, Markus; Sörgel, Fritz; Holzgrabe, Ulrike

    2018-02-20

    Pharmaceutical manufacturers have to study the stability of drug products before marketing according to ICH guideline Q1A(R2); data of those investigations aim to set expiry dates. The expiry date on the container of a remedy assures the physician and the patient a stability of the drug in its formulation i.e. within a specification of 95-105%. Only few studies show that shelf-lives of pharmaceutical products are often longer than expiration dates. The objective of the study presented here was determining the content of nine expired ampoules manufactured in the last century and identifying the impurity profile by means of HPLC-UV and HPLC-MS, respectively. The ampoules are part of the "PEAK-collection" of long expired finished pharmaceutical products at IBMP, Nürnberg-Heroldsberg, and consists among others of epinephrine (Suprarenin and Adrenalin in Oil), etilefrine (Effortil ® ), synephrine (Sympatol ® ), caffeine and procaine (Impletol), caffeine and sodium salicylate (Caffeinum Salicylicum), dipyridamole (Persantin ® ), furosemide (Lasix ® ), and metamizole (Novalgin ® ). For chromatographic investigations methods of the European Pharmacopoeia for related substances were used; for determining the content, they were validated for linearity, precision, and accuracy. The results were compared to current reference ampoules. Five out of nine ampoules were still within the specified content limits. In Suprarenin and Adrenalin in Oil, both containing epinephrine, Impletol (procaine), and Persantin ® (dipyridamole) contents were decreased to 70%, 74%, 79%, and 86%, respectively, and therefore out of specification. Copyright © 2017 Elsevier B.V. All rights reserved.

  1. Analysis and stability of retinol in plasma.

    PubMed

    Peng, Y M; Xu, M J; Alberts, D S

    1987-01-01

    A simple, precise, and specific high-performance liquid chromatography (HPLC) method was developed for the simultaneous measurement of retinol (ROH), 13-cis-retinoic acid (13-cRA), and 4-oxo-13-cRA. The average recovery of ROH from serum or plasma was 95%, and the precision of the assay was less than 5%. With this HPLC method, a series of studies was carried out to evaluate the stability of ROH in various matrices. ROH was stable under our HPLC assay conditions as well as in plasma- and in serum-enriched culture media; however, ROH was not stable in aqueous matrices. Serum or heparinized plasma may be routinely used for measurement of ROH concentrations, providing EDTA, oxalate, and citrate are not used as anticoagulants. Because of ROH stability, blood samples can be kept on ice in the dark for at least 24 hours prior to separation of plasma. In addition, plasma samples containing ROH can be stored for up to 1 year at -20 degrees C without loss of stability.

  2. Comparison of on-site field measured inorganic arsenic in rice with laboratory measurements using a field deployable method: Method validation.

    PubMed

    Mlangeni, Angstone Thembachako; Vecchi, Valeria; Norton, Gareth J; Raab, Andrea; Krupp, Eva M; Feldmann, Joerg

    2018-10-15

    A commercial arsenic field kit designed to measure inorganic arsenic (iAs) in water was modified into a field deployable method (FDM) to measure iAs in rice. While the method has been validated to give precise and accurate results in the laboratory, its on-site field performance has not been evaluated. This study was designed to test the method on-site in Malawi in order to evaluate its accuracy and precision in determination of iAs on-site by comparing with a validated reference method and giving original data on inorganic arsenic in Malawian rice and rice-based products. The method was validated by using the established laboratory-based HPLC-ICPMS. Statistical tests indicated there were no significant differences between on-site and laboratory iAs measurements determined using the FDM (p = 0.263, ά = 0.05) and between on-site measurements and measurements determined using HPLC-ICP-MS (p = 0.299, ά = 0.05). This method allows quick (within 1 h) and efficient screening of rice containing iAs concentrations on-site. Copyright © 2018 Elsevier Ltd. All rights reserved.

  3. Determination and validation of six sunscreen agents in suncare products by UPLC and HPLC.

    PubMed

    Lee, So-Mi; Jeong, Hye-Jin; Chang, Ih Seop

    2008-01-01

    Methylene bis-benzotriazolyl tetramethyl butylphenol and bis-ethylhexyloxy phenol methoxyphenyl triazine are sunscreen agents that have hydrophobic behaviors in common. They were not normally assayed with the following four sunscreen agents that have hydrophilic behaviors in a single chromatographic run: ethylhexyl methoxycinnamate, isoamyl p-methoxycinnamate, ethylhexyl salicylate, and ethylhexyl triazone. For that reason, methylene bis-benzotriazolyl tetramethyl butylphenol and bis-ethylhexyloxy phenol methoxyphenyl triazine require much time in order to assay products with those materials. A rapid, selective, and reproducible determination method needs to be developed for the simultaneous examination of methylene bis-benzotriazolyl tetramethyl butylphenol and bis-ethylhexyloxy phenol methoxyphenyl triazine with the sunscreen agents, ethylhexyl methoxycinnamate, isoamyl p-methoxycinnamate, ethylhexyl salicylate, and ethylhexyl triazone. This new technique could reduce time in examining the sunscreen agents and be effective for quality control of suncare products. In this paper, the HPLC and UPLC system is used for developing the determination of the sunscreen agents. Several evaluations of some mixtures of eluents and columns were obtained for the optimal condition of separation. In HPLC, the optimal peak resolution was obtained through ethanol-water gradient elution and a 75-mm C18 column with a 3.5-microm-sized particle on a flow rate of 1.0 ml/min. In UPLC, the most distinctive peak resolution was obtained through methanol-water gradient elution and a 50-mm C18 column with a 1.7-microm-sized particle on a flow rate 0.4 ml/min. Both of those chromatographic determination methods could be used in the examination of six types of sunscreen agents without any interference from other product excipients in the agents. The proposed determination methods were validated for specificity, linearity, repeatability, system stability, intermediate precision, and accuracy. Consequently, HPLC and UPLC determination methods could be rapid, selective, and proper applications for the assay of sunscreen agents in suncare products.

  4. An HPLC tandem mass spectrometry for quantification of ET-26-HCl and its major metabolite in plasma and application to a pharmacokinetic study in rats.

    PubMed

    Chen, Xu; Zhang, Wensheng; Rios, Sandy; Morkos, Miriam B; Ye, Xiaoli; Li, Gen; Jiang, Xuehua; Wang, Zhijun; Wang, Ling

    2018-02-05

    ET-26-HCl is a new analog of etomidate, a short-acting anesthetic drug, with less adrenal cortex inhibition. The pharmacokinetics of ET-26-HCl in rats needs to be determined for future clinical trials in human subjects. In order to facilitate the pharmacokinetic study, a liquid chromatography based tandem mass spectrometric (HPLC-MS/MS) method was developed and validated for quantification of ET-26-HCl and its major metabolite, ET-26-acid. These two compounds and gabapentin (internal standard) were extracted using a protein precipitation method with methanol and detected by Multiple Reaction Monitoring of m/z transition of 275.6-170.9, 217.7-113.1, and 172.5-154.3 for ET-26-HCl, ET-26-acid, and gabapentin respectively. This method was validated in terms of sensitivity, linearity, reproducibility, and stability. The HPLC-MS/MS method was found linear over the concentration ranges of 21.76-4352ng/mL, and 18.62-3724ng/mL with LLOQ of 21.76 and 18.62ng/mL for ET-26-HCl and ET-26-acid respectively. The mean intra-day and inter-day accuracy was between 94.11-107.78%, while the precision was within the limit of 15.0% for all the quality control samples. A pharmacokinetic study was then conducted in rats following intravenous injection of 2.1, 4.2, and 8.4mg/kg. The linear pharmacokinetics of ET-26-HCl was observed over the dose range of 2.1-8.4mg/kg. The average terminal phase elimination half-lives were 0.87 and 1.03h for ET-26-HCl and ET-26-acid respectively. In summary, an HPLC-MS/MS method for quantification of ET-26-HCl in rat plasma has been developed and successfully applied to a pharmacokinetic study. Copyright © 2017 Elsevier B.V. All rights reserved.

  5. Simultaneous determination of chromones and coumarins in Radix Saposhnikoviae by high performance liquid chromatography with diode array and tandem mass detectors.

    PubMed

    Kim, Min Kyung; Yang, Dong-Hyug; Jung, Mihye; Jung, Eun Ha; Eom, Han Young; Suh, Joon Hyuk; Min, Jung Won; Kim, Unyong; Min, Hyeyoung; Kim, Jinwoong; Han, Sang Beom

    2011-09-16

    Methods using high performance liquid chromatography with diode array detection (HPLC-DAD) and tandem mass spectrometry (HPLC-MS/MS) were developed and validated for the simultaneous determination of 5 chromones and 6 coumarins: prim-O-glucosylcimifugin (1), cimifugin (2), nodakenin (3), 4'-O-β-d-glucosyl-5-O-methylvisamminol (4), sec-O-glucosylhamaudol (5), psoralen (6), bergapten (7), imperatorin (8), phellopterin (9), 3'-O-angeloylhamaudol (10) and anomalin (11), in Radix Saposhnikoviae. The separation conditions for HPLC-DAD were optimized using an Ascentis Express C18 (4.6 mm×100 mm, 2.7 μm particle size) fused-core column. The mobile phase was composed of 10% aqueous acetonitrile (A) and 90% acetonitrile (B) and the elution was performed under a gradient mode at a flow rate of 1.0 mL/min. The detection wavelength was set at 300 nm. The HPLC-DAD method yielded a base line separation of the 11 components in 50% methanol extract of Radix Saposhnikoviae with no interfering peaks detected. The HPLC-DAD method was validated in terms of linearity, accuracy and precision (intra- and inter-day), limit of quantification (LOQ), recovery, and robustness. Specific determination of the 11 components was also accomplished by a triple quadrupole tandem mass spectrometer equipped with an electrospray ionization (ESI) source. This HPLC-MS/MS method was also validated by determining the linearity, limit of quantification, accuracy, and precision. Quantification of the 11 components in 51 commercial Radix Saposhnikoviae samples was successfully performed using the developed HPLC-DAD method. The identity, batch-to-batch consistency, and authenticity of Radix Saposhnikoviae were successfully monitored by the proposed HPLC-DAD and HPLC-MS/MS methods. Copyright © 2011 Elsevier B.V. All rights reserved.

  6. Simultaneous quantification of acetaminophen and five acetaminophen metabolites in human plasma and urine by high-performance liquid chromatography-electrospray ionization-tandem mass spectrometry: Method validation and application to a neonatal pharmacokinetic study.

    PubMed

    Cook, Sarah F; King, Amber D; van den Anker, John N; Wilkins, Diana G

    2015-12-15

    Drug metabolism plays a key role in acetaminophen (paracetamol)-induced hepatotoxicity, and quantification of acetaminophen metabolites provides critical information about factors influencing susceptibility to acetaminophen-induced hepatotoxicity in clinical and experimental settings. The aims of this study were to develop, validate, and apply high-performance liquid chromatography-electrospray ionization-tandem mass spectrometry (HPLC-ESI-MS/MS) methods for simultaneous quantification of acetaminophen, acetaminophen-glucuronide, acetaminophen-sulfate, acetaminophen-glutathione, acetaminophen-cysteine, and acetaminophen-N-acetylcysteine in small volumes of human plasma and urine. In the reported procedures, acetaminophen-d4 and acetaminophen-d3-sulfate were utilized as internal standards (IS). Analytes and IS were recovered from human plasma (10μL) by protein precipitation with acetonitrile. Human urine (10μL) was prepared by fortification with IS followed only by sample dilution. Calibration concentration ranges were tailored to literature values for each analyte in each biological matrix. Prepared samples from plasma and urine were analyzed under the same HPLC-ESI-MS/MS conditions, and chromatographic separation was achieved through use of an Agilent Poroshell 120 EC-C18 column with a 20-min run time per injected sample. The analytes could be accurately and precisely quantified over 2.0-3.5 orders of magnitude. Across both matrices, mean intra- and inter-assay accuracies ranged from 85% to 112%, and intra- and inter-assay imprecision did not exceed 15%. Validation experiments included tests for specificity, recovery and ionization efficiency, inter-individual variability in matrix effects, stock solution stability, and sample stability under a variety of storage and handling conditions (room temperature, freezer, freeze-thaw, and post-preparative). The utility and suitability of the reported procedures were illustrated by analysis of pharmacokinetic samples collected from neonates receiving intravenous acetaminophen. Copyright © 2015 Elsevier B.V. All rights reserved.

  7. Chemical fingerprint and simultaneous determination of alkaloids and flavonoids in aerial parts of genus Peganum indigenous to China based on HPLC-UV: application of analysis on secondary metabolites accumulation.

    PubMed

    Wen, Fangfang; Cheng, Xuemei; Liu, Wei; Xuan, Min; Zhang, Lei; Zhao, Xin; Shan, Meng; Li, Yan; Teng, Liang; Wang, Zhengtao; Wang, Changhong

    2014-12-01

    The aerial parts of genus Peganum are officially used in traditional Chinese medicine. The paper aims to establish a high-performance liquid chromatography (HPLC) method for fingerprint analysis and simultaneous determination of three alkaloids and two flavonoids in aerial parts of genus Peganum, and to analyze accumulative difference of secondary metabolites in inter-species, individuals of plants, inter-/intra-population and from different growing seasons. HPLC analysis was performed on a C18 column with gradient elution using 0.1% trifloroacetic acid and acetonitrile as mobile phase and detected at 265 nm, by conventional methodology validation. For fingerprint analysis, the RSDs of relative retention time and relative peak area of the characteristic peaks were within 0.07-0.78 and 0.94-9.09%, respectively. For simultaneous determination of vasicine, harmaline, harmine, deacetylpeganetin and peganetin, all calibration curves showed good linearity (r > 0.9990) within the test range. The relative standard deviations of precision, repeatability and stability test did not exceed 2.37, 2.68 and 2.67%, respectively. The average recoveries for the five analytes were between 96.47 and 101.20%. HPLC fingerprints play a minor role in authenticating and differentiating the herbs of different species of genus Peganum. However, the secondary metabolites levels of alkaloids and flavonoids in aerial parts of genus Peganum rely on species-, habitat-, and growth season-dependent accumulation. Copyright © 2014 John Wiley & Sons, Ltd.

  8. Application of spectrophotometric, densitometric, and HPLC techniques as stability indicating methods for determination of Zaleplon in pharmaceutical preparations

    NASA Astrophysics Data System (ADS)

    Metwally, Fadia H.; Abdelkawy, M.; Abdelwahab, Nada S.

    2007-12-01

    Spectrophotometric, spectrodensitometric and HPLC are stability indicating methods described for determination of Zaleplon in pure and dosage forms. As Zaleplon is easily degradable, the proposed techniques in this manuscript are adopted for its determination in presence of its alkaline degradation product, namely N-[4-(3-cyano-pyrazolo[1,5a]pyridin-7-yl)-phenyl]- N-ethyl-acetamide. These approaches are successfully applied to quantify Zaleplon using the information included in the absorption spectra of appropriate solutions. The second derivative (D 2) spectrophotometric method, allows determination of Zaleplon without interference of its degradate at 235.2 nm using 0.01N HCl as a solvent with obedience to Beer's law over a concentration range of 1-10 μg ml -1 with mean percentage recovery 100.24 ± 0.86%. The first derivative of the ratio spectra ( 1DD) based on the simultaneous use of ( 1DD) and measurement at 241.8 nm using the same solvent and over the same concentration range as (D 2) spectrophotometric method, with mean percentage recovery 99.9 ± 1.07%. The spectrodensitometric analysis allows the separation and quantitation of Zaleplon from its degradate on silica gel plates using chloroform:acetone:ammonia solution (9:1:0.2 by volume) as a mobile phase. This method depends on quantitave densitometric evaluation of thin layer chromatogram of Zaleplon at 338 nm over a concentration range of 0.2-1 μg band -1, with mean percentage recovery 99.73 ± 1.35. Also a reversed-phase liquid chromatographic method using 5-C8 (22 cm × 4.6 mm i.d. 5 μm particle size) column was described and validated for quantitation of Zaleplon using acetonitrile:deionised water (35:65, v/v) as a mobile phase using Paracetamol as internal standard and a flow rate of 1.5 ml min -1 with UV detection of the effluent at 232 nm at ambient temperature over a concentration range of 2-20 μg ml -1 with mean percentage recovery 100.19 ± 1.15%. The insignificance difference of the proposed methods results with those of the reference one proved their accuracy and precision.

  9. Determination of Urine Albumin by New Simple High-Performance Liquid Chromatography Method.

    PubMed

    Klapkova, Eva; Fortova, Magdalena; Prusa, Richard; Moravcova, Libuse; Kotaska, Karel

    2016-11-01

    A simple high-performance liquid chromatography (HPLC) method was developed for the determination of albumin in patients' urine samples without coeluting proteins and was compared with the immunoturbidimetric determination of albumin. Urine albumin is important biomarker in diabetic patients, but part of it is immuno-nonreactive. Albumin was determined by high-performance liquid chromatography (HPLC), UV detection at 280 nm, Zorbax 300SB-C3 column. Immunoturbidimetric analysis was performed using commercial kit on automatic biochemistry analyzer COBAS INTEGRA ® 400, Roche Diagnostics GmbH, Manheim, Germany. The HLPC method was fully validated. No significant interference with other proteins (transferrin, α-1-acid glycoprotein, α-1-antichymotrypsin, antitrypsin, hemopexin) was found. The results from 301 urine samples were compared with immunochemical determination. We found a statistically significant difference between these methods (P = 0.0001, Mann-Whitney test). New simple HPLC method was developed for the determination of urine albumin without coeluting proteins. Our data indicate that the HPLC method is highly specific and more sensitive than immunoturbidimetry. © 2016 Wiley Periodicals, Inc.

  10. Development of an Ultrasonication-Assisted Extraction Based HPLC With a Fluorescence Method for Sensitive Determination of Aflatoxins in Highly Acidic Hibiscus sabdariffa

    PubMed Central

    Liu, Xiaofei; Ying, Guangyao; Sun, Chaonan; Yang, Meihua; Zhang, Lei; Zhang, Shanshan; Xing, Xiaoyan; Li, Qian; Kong, Weijun

    2018-01-01

    The high acidity and complex components of Hibiscus sabdariffa have provided major challenges for sensitive determination of trace aflatoxins. In this study, sample pretreatment of H. sabdariffa was systematically developed for sensitive high performance liquid chromatography-fluorescence detection (HPLC-FLD) after ultrasonication-assisted extraction, immunoaffinity column (IAC) clean-up and on-line post-column photochemical derivatization (PCD). Aflatoxins B1, B2, G1, G2 were extracted from samples by using methanol/water (70:30, v/v) with the addition of NaCl. The solutions were diluted 1:8 with 0.1 M phosphate buffer (pH 8.0) to negate the issues of high acidity and matrix interferences. The established method was validated with satisfactory linearity (R > 0.999), sensitivity (limits of detection (LODs) and limits of quantitation (LOQs) of 0.15–0.65 and 0.53–2.18 μg/kg, respectively), precision (RSD <11%), stability (RSD of 0.2–3.6%), and accuracy (recovery rates of 86.0–102.3%), which all met the stipulated analytical requirements. Analysis of 28 H. sabdariffa samples indicated that one sample incubated with Aspergillus flavus was positive with aflatoxin B1 (AFB1) at 3.11 μg/kg. The strategy developed in this study also has the potential to reliably extract and sensitively detect more mycotoxins in other complex acidic matrices, such as traditional Chinese medicines, foodstuffs, etc. PMID:29681848

  11. Development of an Ultrasonication-Assisted Extraction Based HPLC With a Fluorescence Method for Sensitive Determination of Aflatoxins in Highly Acidic Hibiscus sabdariffa.

    PubMed

    Liu, Xiaofei; Ying, Guangyao; Sun, Chaonan; Yang, Meihua; Zhang, Lei; Zhang, Shanshan; Xing, Xiaoyan; Li, Qian; Kong, Weijun

    2018-01-01

    The high acidity and complex components of Hibiscus sabdariffa have provided major challenges for sensitive determination of trace aflatoxins. In this study, sample pretreatment of H. sabdariffa was systematically developed for sensitive high performance liquid chromatography-fluorescence detection (HPLC-FLD) after ultrasonication-assisted extraction, immunoaffinity column (IAC) clean-up and on-line post-column photochemical derivatization (PCD). Aflatoxins B 1 , B 2 , G 1 , G 2 were extracted from samples by using methanol/water (70:30, v/v ) with the addition of NaCl. The solutions were diluted 1:8 with 0.1 M phosphate buffer (pH 8.0) to negate the issues of high acidity and matrix interferences. The established method was validated with satisfactory linearity ( R > 0.999), sensitivity (limits of detection (LODs) and limits of quantitation (LOQs) of 0.15-0.65 and 0.53-2.18 μg/kg, respectively), precision (RSD <11%), stability (RSD of 0.2-3.6%), and accuracy (recovery rates of 86.0-102.3%), which all met the stipulated analytical requirements. Analysis of 28 H. sabdariffa samples indicated that one sample incubated with Aspergillus flavus was positive with aflatoxin B 1 (AFB 1 ) at 3.11 μg/kg. The strategy developed in this study also has the potential to reliably extract and sensitively detect more mycotoxins in other complex acidic matrices, such as traditional Chinese medicines, foodstuffs, etc.

  12. A novel automated hydrophilic interaction liquid chromatography method using diode-array detector/electrospray ionization tandem mass spectrometry for analysis of sodium risedronate and related degradation products in pharmaceuticals.

    PubMed

    Bertolini, Tiziana; Vicentini, Lorenza; Boschetti, Silvia; Andreatta, Paolo; Gatti, Rita

    2014-10-24

    A simple, sensitive and fast hydrophilic interaction liquid chromatography (HILIC) method using ultraviolet diode-array detector (UV-DAD)/electrospray ionization tandem mass spectrometry was developed for the automated high performance liquid chromatography (HPLC) determination of sodium risedronate (SR) and its degradation products in new pharmaceuticals. The chromatographic separations were performed on Ascentis Express HILIC 2.7μm (150mm×2.1mm, i.d.) stainless steel column (fused core). The mobile phase consisted of formate buffer solution (pH 3.4; 0.03M)/acetonitrile 42:58 and 45:55 (v/v) for granules for oral solution and effervescent tablet analysis, respectively, at a flow-rate of 0.2mL/min, setting the wavelength at 262nm. Stability characteristics of SR were evaluated by performing stress test studies. The main degradation product formed under oxidation conditions corresponding to sodium hydrogen (1-hydroxy-2-(1-oxidopyridin-3-yl)-1-phosphonoethyl)phosphonate was characterized by high performance liquid chromatography-electrospray ionization-mass tandem mass spectrometry (HPLC-ESI-MS/MS). The validation parameters such as linearity, sensitivity, accuracy, precision and selectivity were found to be highly satisfactory. Linear responses were observed in standard and in fortified placebo solutions. Intra-day precision (relative standard deviation, RSD) was ≤1.1% for peak area and ≤0.2% for retention times (tR) without significant differences between intra- and inter-day data. Recovery studies showed good results for all the examined compounds (from 98.7 to 101.0%) with RSD ranging from 0.6 to 0.7%. The limits of detection (LOD) and quantitation (LOQ) were 1 and 3ng/mL, respectively. The high stability of standard and sample solutions at room temperature means an undoubted advantage of the method allowing the simultaneous preparation of many samples and consecutive chromatographic analyses by using an autosampler. The developed stability indicating method is suitable for the quality control of SR in new and commercial pharmaceutical formulations. Copyright © 2014 Elsevier B.V. All rights reserved.

  13. Stability-indicating HPLC-DAD/UV-ESI/MS impurity profiling of the anti-malarial drug lumefantrine.

    PubMed

    Verbeken, Mathieu; Suleman, Sultan; Baert, Bram; Vangheluwe, Elien; Van Dorpe, Sylvia; Burvenich, Christian; Duchateau, Luc; Jansen, Frans H; De Spiegeleer, Bart

    2011-02-28

    Lumefantrine (benflumetol) is a fluorene derivative belonging to the aryl amino alcohol class of anti-malarial drugs and is commercially available in fixed combination products with β-artemether. Impurity characterization of such drugs, which are widely consumed in tropical countries for malaria control programmes, is of paramount importance. However, until now, no exhaustive impurity profile of lumefantrine has been established, encompassing process-related and degradation impurities in active pharmaceutical ingredients (APIs) and finished pharmaceutical products (FPPs). Using HPLC-DAD/UV-ESI/ion trap/MS, a comprehensive impurity profile was established based upon analysis of market samples as well as stress, accelerated and long-term stability results. In-silico toxicological predictions for these lumefantrine related impurities were made using Toxtree® and Derek®. Several new impurities are identified, of which the desbenzylketo derivative (DBK) is proposed as a new specified degradant. DBK and the remaining unspecified lumefantrine related impurities are predicted, using Toxtree® and Derek®, to have a toxicity risk comparable to the toxicity risk of the API lumefantrine itself. From unstressed, stressed and accelerated stability samples of lumefantrine API and FPPs, nine compounds were detected and characterized to be lumefantrine related impurities. One new lumefantrine related compound, DBK, was identified and characterized as a specified degradation impurity of lumefantrine in real market samples (FPPs). The in-silico toxicological investigation (Toxtree® and Derek®) indicated overall a toxicity risk for lumefantrine related impurities comparable to that of the API lumefantrine itself.

  14. Stability of gabapentin in extemporaneously compounded oral suspensions

    PubMed Central

    Friciu, Mihaela; Roullin, V. Gaëlle

    2017-01-01

    This study reports the stability of extemporaneously prepared gabapentin oral suspensions prepared at 100 mg/mL from bulk drug and capsules in either Oral Mix or Oral Mix SF suspending vehicles. Suspensions were packaged in amber plastic bottles and amber plastic syringes at 25°C / 60%RH for up to 90 days. Throughout the study period, the following tests were performed to evaluate the stability of the preparations: organoleptic inspection to detect homogeneity, color or odor changes; pH measurements; and gabapentin assay using a stability-indicating HPLC-UV method. As crystallization was observed at 5°C, storage at this temperature condition is not recommended. All preparations stored at 25°C / 60%RH remained stable for the whole study duration of 90 days. PMID:28414771

  15. Stability-indicating method for simultaneous estimation of olmesartan medoxomile, amlodipine besylate and hydrochlorothiazide by RP-HPLC in tablet dosage form.

    PubMed

    Jain, P S; Patel, M K; Gorle, A P; Chaudhari, A J; Surana, S J

    2012-09-01

    A simple, specific, accurate and precise stability-indicating reversed-phase high-performance liquid chromatographic method was developed for simultaneous estimation of olmesartan medoxomile (OLME), amlodipine besylate (AMLO) and hydrochlorothiazide (HCTZ) in tablet dosage form. The method was developed using an RP C18 base deactivated silica column (250 × 4.6 mm, 5 µm) with a mobile phase consisting of triethylamine (pH 3.0) adjusted with orthophosphoric acid (A) and acetonitrile (B), with a timed gradient program of T/%B: 0/30, 7/70, 8/30, 10/30 with a flow rate of 1.4 mL/min. Ultraviolet detection was used at 236 nm. The retention times for OLME, AMLO and HCTZ were found to be 6.72, 4.28 and 2.30, respectively. The proposed method was validated for precision, accuracy, linearity, range, robustness, ruggedness and force degradation study. The calibration curves of OLME, AMLO and HCTZ were linear over the range of 50-150, 12.5-37.5 and 31-93 µg/mL, respectively. The method was found to be sensitive. The limits of detection of OLME, AMLO and HCTZ were determined 0.19, 0.16 and 0.22 µg/mL and limits of quantification of OLME, AMLO and HCTZ were determined 0.57, 0.49 and 0.66, respectively. Forced degradation study was performed according to International Conference on Harmonization guidelines.

  16. Development of an extemporaneous oral liquid formulation of oxandrolone and its stability evaluation.

    PubMed

    Garg, Alka; Garg, Sanjay; She, Richard Wong

    2011-11-01

    Many references exist in the literature identifying the usefulness of oxandrolone in treating muscle wasting due to various conditions including severe burns. However, there is an absence of dosage form alternatives as it is only available as tablets. The dose for children is weight based (0.1 mg/kg) which is difficult to achieve with the currently available tablets of 2.5 mg and 10 mg. The literature provides ample evidence of clinical importance but little guidance on extemporaneous oral liquid formulation of oxandrolone. In order to develop and validate an extemporaneous liquid formulation, suspensions of oxandrolone were developed using locally available (New Zealand) vehicles. Combinations of these vehicles with ethanol, as advised in some articles were also tried. Assay method was developed for oxandrolone using High Performance Liquid Chromatography (HPLC) and Mass Spectroscopy (LC-MS). The formulations were evaluated for stability as per the International Conference on Harmonization (ICH) stability guidelines. They were observed for physical and chemical stability at different time points over a period of 28 days. A stable and validated liquid formulation of oxandrolone has been developed which can be made under the hospital and community pharmacy conditions. The formula utilises commercially available oxandrolone tablets, crushed and dispersed in Simple Syrup BP or Orablend(®) vehicle. The formulation has confirmed stability for 21 days and can be easily made with locally available vehicles. Copyright © 2011 Elsevier Ltd and ISBI. All rights reserved.

  17. RP-HPLC method development and validation for simultaneous estimation of atorvastatin calcium and pioglitazone hydrochloride in pharmaceutical dosage form.

    PubMed

    Peraman, Ramalingam; Mallikarjuna, Sasikala; Ammineni, Pravalika; Kondreddy, Vinod kumar

    2014-10-01

    A simple, selective, rapid, precise and economical reversed-phase high-performance liquid chromatographic (RP-HPLC) method has been developed for simultaneous estimation of atorvastatin calcium (ATV) and pioglitazone hydrochloride (PIO) from pharmaceutical formulation. The method is carried out on a C8 (25 cm × 4.6 mm i.d., 5 μm) column with a mobile phase consisting of acetonitrile (ACN):water (pH adjusted to 6.2 using o-phosphoric acid) in the ratio of 45:55 (v/v). The retention time of ATV and PIO is 4.1 and 8.1 min, respectively, with the flow rate of 1 mL/min with diode array detector detection at 232 nm. The linear regression analysis data from the linearity plot showed good linear relationship with a correlation coefficient (R(2)) value for ATV and PIO of 0.9998 and 0.9997 in the concentration range of 10-80 µg mL(-1), respectively. The relative standard deviation for intraday precision has been found to be <2.0%. The method is validated according to the ICH guidelines. The developed method is validated in terms of specificity, selectivity, accuracy, precision, linearity, limit of detection, limit of quantitation and solution stability. The proposed method can be used for simultaneous estimation of these drugs in marketed dosage forms. © The Author [2013]. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.

  18. HPLC fingerprint analysis combined with chemometrics for pattern recognition of ginger.

    PubMed

    Feng, Xu; Kong, Weijun; Wei, Jianhe; Ou-Yang, Zhen; Yang, Meihua

    2014-03-01

    Ginger, the fresh rhizome of Zingiber officinale Rosc. (Zingiberaceae), has been used worldwide; however, for a long time, there has been no standard approbated internationally for its quality control. To establish an efficacious and combinational method and pattern recognition technique for quality control of ginger. A simple, accurate and reliable method based on high-performance liquid chromatography with photodiode array (HPLC-PDA) detection was developed for establishing the chemical fingerprints of 10 batches of ginger from different markets in China. The method was validated in terms of precision, reproducibility and stability; and the relative standard deviations were all less than 1.57%. On the basis of this method, the fingerprints of 10 batches of ginger samples were obtained, which showed 16 common peaks. Coupled with similarity evaluation software, the similarities between each fingerprint of the sample and the simulative mean chromatogram were in the range of 0.998-1.000. Then, the chemometric techniques, including similarity analysis, hierarchical clustering analysis and principal component analysis were applied to classify the ginger samples. Consistent results were obtained to show that ginger samples could be successfully classified into two groups. This study revealed that HPLC-PDA method was simple, sensitive and reliable for fingerprint analysis, and moreover, for pattern recognition and quality control of ginger.

  19. Simultaneous determination of leucine, isoleucine and valine in Beagle dog plasma by HPLC-MS/MS and its application to a pharmacokinetic study.

    PubMed

    Wang, Ting; Xie, Huiru; Chen, Xu; Jiang, Xuehua; Wang, Ling

    2015-10-10

    Leucine (Leu), isoleucine (Ile) and valine (Val) are three branched-chain amino acids (BCAAs), which have been widely used as dietary supplements for professional athletes and patients with liver failure or catabolic diseases. To date, no pharmacokinetic studies of BCAAs in vivo useful for the assessment of clinical effect following daily intake has been reported. Thus in this study, an HPLC-MS/MS method for simultaneous determination of Leu, Ile and Val in Beagle dog plasma using homoarginine as the internal standard was developed and validated in terms of specificity, linearity, precision, accuracy, and stability. This assay method was then applied to a pharmacokinetic study of BCAAs in dogs following oral administration of 0.25 g/kg and 0.50 g/kg BCAAs. The HPLC-MS/MS method was found to be sensitive and reproducible for quantification of BCAAs in dog plasma and successfully applied to the pharmacokinetic study. All these BCAAs were well absorbed with a substantial increase in the plasma concentration after a baseline modification. No statistical significance was identified in different gender group and no drug accumulation was observed following multiple doses. Copyright © 2015 Elsevier B.V. All rights reserved.

  20. Determination of Trace Elements in Uranium by HPLC-ID-ICP-MS: NTNFC Final Report

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Manard, Benjamin Thomas; Wylie, Ernest Miller II; Xu, Ning

    This report covers the FY 16 effort for the HPLC-ID-ICP-MS methodology 1) sub-method validation for the group I&II elements, 2) sub-method stood-up and validation for REE, 3) sub-method development for the transition element, and 4) completion of a comprehensive SOP for three families of elements.

  1. ICH guidance in practice: validated reversed-phase HPLC method for the determination of active mangiferin from extracts of Mangifera indica Linn.

    PubMed

    Gowda, Nagaraj; Kumar, Pradeep; Panghal, Surender; Rajshree, Mashru

    2010-02-01

    This study presents the development and validation of a reversed-phase liquid chromatographic method for the determination of mangiferin (MGN) in alcoholic extracts of mangifera indica. A Lichrospher 100 C(18)-ODS (250 x 4.6 mm, 5 microm size) (Merck, Whitehouse Station, NJ) prepacked column and a mobile phase of potassium dihydrogen orthophosphate (0.01M) pH 2.7 +/- 0.2-acetonitrile (15:85, v/v) with the flow rate of 1 mL/min was used. MGN detection was achieved at a wavelength monitored at 254 nm with SPD-M 10A vp PDA detector or SPD 10AD vp UV detector in combination with class LC 10A software. The proposed method was validated as prescribed by International Conference on Harmonization (ICH) with respect to linearity, specificity, accuracy, precision, stability, and quantification. The method validation was realized using alcoholic extracts and raw materials of leaves and barks. All the validation parameters were within the acceptable limits, and the developed analytical method can successfully be applied for MGN determination.

  2. Development and Validation of an HPLC Method for Karanjin in Pongamia pinnata linn. Leaves.

    PubMed

    Katekhaye, S; Kale, M S; Laddha, K S

    2012-01-01

    A rapid, simple and specific reversed-phase HPLC method has been developed for analysis of karanjin in Pongamia pinnata Linn. leaves. HPLC analysis was performed on a C(18) column using an 85:13.5:1.5 (v/v) mixtures of methanol, water and acetic acid as isocratic mobile phase at a flow rate of 1 ml/min. UV detection was at 300 nm. The method was validated for accuracy, precision, linearity, specificity. Validation revealed the method is specific, accurate, precise, reliable and reproducible. Good linear correlation coefficients (r(2)>0.997) were obtained for calibration plots in the ranges tested. Limit of detection was 4.35 μg and limit of quantification was 16.56 μg. Intra and inter-day RSD of retention times and peak areas was less than 1.24% and recovery was between 95.05 and 101.05%. The established HPLC method is appropriate enabling efficient quantitative analysis of karanjin in Pongamia pinnata leaves.

  3. Development and Validation of an HPLC Method for Karanjin in Pongamia pinnata linn. Leaves

    PubMed Central

    Katekhaye, S; Kale, M. S.; Laddha, K. S.

    2012-01-01

    A rapid, simple and specific reversed-phase HPLC method has been developed for analysis of karanjin in Pongamia pinnata Linn. leaves. HPLC analysis was performed on a C18 column using an 85:13.5:1.5 (v/v) mixtures of methanol, water and acetic acid as isocratic mobile phase at a flow rate of 1 ml/min. UV detection was at 300 nm. The method was validated for accuracy, precision, linearity, specificity. Validation revealed the method is specific, accurate, precise, reliable and reproducible. Good linear correlation coefficients (r2>0.997) were obtained for calibration plots in the ranges tested. Limit of detection was 4.35 μg and limit of quantification was 16.56 μg. Intra and inter-day RSD of retention times and peak areas was less than 1.24% and recovery was between 95.05 and 101.05%. The established HPLC method is appropriate enabling efficient quantitative analysis of karanjin in Pongamia pinnata leaves. PMID:23204626

  4. Construction of a hydrazone-linked chiral covalent organic framework-silica composite as the stationary phase for high performance liquid chromatography.

    PubMed

    Zhang, Kai; Cai, Song-Liang; Yan, Yi-Lun; He, Zi-Hao; Lin, Hui-Mei; Huang, Xiao-Ling; Zheng, Sheng-Run; Fan, Jun; Zhang, Wei-Guang

    2017-10-13

    Covalent organic frameworks (COFs), as an emerging class of crystalline porous organic polymers, have great potential for applications in chromatographic separation owning to their fascinating crystalline structures and outstanding properties. However, development of COF materials as novel stationary phases in high performance liquid chromatography (HPLC) is just in its infancy. Herein, we report the design and construction of a new hydrazone-linked chiral COF, termed BtaMth COF, from a chiral hydrazide building block (Mth) and present a one-pot synthetic method for the fabrication of BtaMth@SiO 2 composite for HPLC separation of isomers. The as-synthesized BtaMth chiral COF displays good crystallinity, high porosity, as well as excellent chemical stability. Meanwhile, the fabricated HPLC column by using BtaMth@SiO 2 composite as the new stationary phase exhibits high resolution performances for the separation of positional isomers including nitrotoluene and nitrochlorobenzene, as well as cis-trans isomers including beta-cypermethrin and metconazole. Additionally, some effects such as the composition of the mobile phase and column temperature for HPLC separations on the BtaMth@SiO 2 packed column also have been studied in detail. The successful applications indicate the great potentials of hydrazone-linked chiral COF-silica composite as novel stationary phase for the efficient HPLC separation. Copyright © 2017 Elsevier B.V. All rights reserved.

  5. Simultaneous determination of five coumarins in Angelicae dahuricae Radix by HPLC/UV and LC-ESI-MS/MS.

    PubMed

    Park, Ah Yeon; Park, So-Young; Lee, Jaehyun; Jung, Mihye; Kim, Jinwoong; Kang, Sam Sik; Youm, Jeong-Rok; Han, Sang Beom

    2009-10-01

    Rapid, simple and reliable HPLC/UV and LC-ESI-MS/MS methods for the simultaneous determination of five active coumarins of Angelicae dahuricae Radix, byakangelicol (1), oxypeucedanin (2), imperatorin (3), phellopterin (4) and isoimperatorin (5) were developed and validated. The separation condition for HPLC/UV was optimized using a Develosil RPAQUEOUS C(30) column using 70% acetonitrile in water as the mobile phase. This HPLC/UV method was successful for providing the baseline separation of the five coumarins with no interfering peaks detected in the 70% ethanol extract of Angelicae dahuricae Radix. The specific determination of the five coumarins was also accomplished by a triple quadrupole tandem mass spectrometer equipped with an electrospray ionization source (LC-ESI-MS/MS). Multiple reaction monitoring (MRM) in the positive mode was used to enhance the selectivity of detection. The LC-ESI-MS/MS methods were successfully applied for the determination of the five major coumarins in Angelicae dahuricae Radix. These HPLC/UV and LC-ESI-MS/MS methods were validated in terms of recovery, linearity, accuracy and precision (intra- and inter-day validation). Taken together, the shorter analysis time involved makes these HPLC/UV and LC-ESI-MS/MS methods valuable for the commercial quality control of Angelicae dahuricae Radix extracts and its pharmaceutical preparations. Copyright (c) 2009 John Wiley & Sons, Ltd.

  6. Evaluation of hemoglobin A1c measurement from filter paper using high-performance liquid chromatography and immunoturbidimetric assay.

    PubMed

    Wu, Yonghua; Yang, Xu; Wang, Haining; Li, Zhenrong; Wang, Tiancheng

    2017-04-01

    Glycated hemoglobin (HbA 1c ) measurement from whole blood (WB) samples is inconvenient for epidemic surveillance and self-monitoring of glycemic level. We evaluated HbA 1c measurement from WB blotted on filter paper (FP), which can be easily transported to central laboratories, with high-performance liquid chromatography (HPLC) and immunoturbidimetric assay (ITA). WB was applied to Whatman filter paper. By using HPLC and WB samples as reference methods, these FP samples were evaluated on HPLC and ITA. Inter- and intra-assay variation, WB vs. FP agreement and sample stability at 20-25 °C and -70 °C were assessed by statistical analysis. Results showed that the coefficient of variation (CV, %) of FP samples for HPLC and ITA were 0.44-1.02% and 1.47-2.72%, respectively (intra-assay); 2.13-3.56% and 3.21-4.82%, respectively (inter-assay). The correlation of WB HPLC with FP analyzed using HPLC and ITA are both significant (p < 0.001). Sample stability showed that FP method up to 5 days at 20-25 °C and 5 weeks at -70 °C is accurate and reproducible. In conclusion, FP samples analyzed by HPLC and ITA can both provide an alternative to WB for HbA 1c measurement, supporting the use of FP method in epidemic surveillance and healthcare units.

  7. Detection and quantification of the selective EP4 receptor antagonist CJ-023423 (grapiprant) in canine plasma by HPLC with spectrofluorimetric detection.

    PubMed

    Vito, Virgina De; Saba, Alessandro; Lee, Hong-Ki; Owen, Helen; Poapolathep, Amnart; Giorgi, Mario

    2016-01-25

    Grapiprant, a novel pharmacologically active ingredient, acts as a selective EP4 receptor antagonist whose physiological ligand is prostaglandin E2 (PGE2). It is currently under development for use in humans and dogs for the control of pain and inflammation associated with osteoarthritis. The aim of the present study was to develop an easy and sensitive method to quantify grapiprant in canine plasma and to apply the method in a canine patient. Several parameters, both in the extraction and detection method were evaluated. The final mobile phase consisted of ACN:AcONH4 (20 mM) solution, pH 4 (70:30, v/v) at a flow rate of 1 mL/min. The elution of grapiprant and IS (metoclopramide) was carried out in isocratic mode through a Synergi Polar-RP 80A analytical column (150 mm × 4.6 mm). The best excitation and emission wavelengths were 320 and 365 nm, respectively. Grapiprant was extracted from the plasma using CHCl3, which gave a recovery of 88.1 ± 10.22% and a lower limit of quantification (LLOQ) of 10 ng/mL. The method was validated in terms of linearity, limit of detection (LOD), LLOQ, selectivity, accuracy and precision, extraction recovery, stability, and inter-laboratory cross validation, according to international guidelines. The chromatographic runs were specific with no interfering peaks at the retention times of the analyte and IS, as confirmed by HPLC-MS experiments. In conclusion, this was a simple and effective method using HPLC-FL to detect grapiprant in plasma, which may be useful for future pharmacokinetic studies. Copyright © 2015 Elsevier B.V. All rights reserved.

  8. Determination of prodrug treosulfan and its biologically active monoepoxide in rat plasma, liver, lungs, kidneys, muscle, and brain by HPLC-ESI-MS/MS method.

    PubMed

    Romański, Michał; Kasprzyk, Anna; Teżyk, Artur; Widerowska, Agnieszka; Żaba, Czesław; Główka, Franciszek

    2017-06-05

    A prodrug treosulfan (TREO) is currently investigated in clinical trials for conditioning prior to hematopoietic stem cell transplantation. Bioanalysis of TREO and its active derivatives, monoepoxide (S,S-EBDM) and diepoxide, in plasma and urine underlay the pharmacokinetic studies of these compounds but cannot explain an organ pharmacological action or toxicity. Recently, distribution of TREO and S,S-EBDM into brain, cerebrospinal fluid, and aqueous humor of the eye has been investigated in animal models and the obtained results presented clinical relevance. In this paper, a selective and rapid HPLC-ESI-MS/MS method was elaborated and validated for the studies of disposition of TREO and S,S-EBDM in rat plasma, liver, lungs, kidneys, muscle, and brain. The two analytes and codeine, internal standard (IS), were isolated from 50μL of plasma and 100μL of supernatants of the tissues homogenates using ultrafiltration Amicon vials. Chromatographic resolution was accomplished on C18 column with isocratic elution. The limits of quantitation of TREO and S,S-EBDM in the studied matrices ranged from 0.11 to 0.93μM. The HPLC-MS/MS method was adequately precise and accurate within and between runs. The IS-normalized matrix effect differed among the tissues and was the most pronounced in a liver homogenate supernatant (approximately 0.55 for TREO and 0.35 for S,S-EBDM). Stability of the analytes in experimental samples was also established. The validated method for the first time enabled determination of TREO and S,S-EBDM in the six life-important tissues in rats following administration of the prodrug. Copyright © 2017 Elsevier B.V. All rights reserved.

  9. Stability of aspartame and neotame in pasteurized and in-bottle sterilized flavoured milk.

    PubMed

    Kumari, Anuradha; Choudhary, Sonika; Arora, Sumit; Sharma, Vivek

    2016-04-01

    Analytical high performance liquid chromatography (HPLC) conditions were standardized along with the isolation procedure for separation of aspartame and neotame in flavoured milk (pasteurized and in-bottle sterilized flavoured milk). The recovery of the method was approximately 98% for both aspartame and neotame. The proposed HPLC method can be successfully used for the routine determination of aspartame and neotame in flavoured milk. Pasteurization (90 °C/20 min) resulted in approximately 40% loss of aspartame and only 8% of neotame was degraded. On storage (4-7°C/7 days) aspartame and neotame content decreased significantly (P<0.05) from 59.70% to 44.61% and 91.78% to 87.18%, respectively. Sterilization (121 °C/15 min) resulted in complete degradation of aspartame; however, 50.50% of neotame remained intact. During storage (30 °C/60 days) neotame content decreased significantly (P<0.05) from 50.36% to 8.67%. Results indicated that neotame exhibited better stability than aspartame in both pasteurized and in-bottle sterilized flavoured milk. Copyright © 2015 Elsevier Ltd. All rights reserved.

  10. Stability indicating HPLC method for the estimation of oxycodone and lidocaine in rectal gel.

    PubMed

    Gebauer, M G; McClure, A F; Vlahakis, T L

    2001-07-31

    An HPLC method for the quantification of oxycodone and lidocaine in a gel matrix is described. The mobile phase consisted of methanol--water--acetic acid (35:15:1 v/v/v) and was delivered at 1.5 ml/min through a 4.6 x 250 mm Zorbax SB-C8 column. Oxycodone was detected at 285 nm and lidocaine at 264 nm. Linear calibration curves were obtained for oxycodone in the range of 0.05--1.5% (w/w) and for lidocaine in the range of 0.1--5.0% (w/w). Oxycodone and lidocaine were treated with hydrogen peroxide and the oxidation products were readily separated on the column. The method was applied to assess the stability of a gel containing oxycodone hydrochloride (0.3% w/w) and lidocaine (1.5% w/w). The gel was stored under refrigeration in ready-to-use syringes and under these conditions oxycodone and lidocaine were stable for at least 1 year. The gel is useful in the management of tenesmus in rectal cancer.

  11. Direct high-performance liquid chromatography method with refractometric detection designed for stability studies of treosulfan and its biologically active epoxy-transformers.

    PubMed

    Główka, Franciszek K; Romański, Michał; Teżyk, Artur; Żaba, Czesław

    2013-01-01

    Treosulfan (TREO) is an alkylating agent registered for treatment of advanced platin-resistant ovarian carcinoma. Nowadays, TREO is increasingly applied iv in high doses as a promising myeloablative agent with low organ toxicity in children. Under physiological conditions it undergoes pH-dependent transformation into epoxy-transformers (S,S-EBDM and S,S-DEB). The mechanism of this reaction is generally known, but not its kinetic details. In order to investigate kinetics of TREO transformation, HPLC method with refractometric detection for simultaneous determination of the three analytes in one analytical run has been developed for the first time. The samples containing TREO, S,S-EBDM, S,S-DEB and acetaminophen (internal standard) were directly injected onto the reversed phase column. To assure stability of the analytes and obtain their complete resolution, mobile phase composed of acetate buffer pH 4.5 and acetonitrile was applied. The linear range of the calibration curves of TREO, S,S-EBDM and S,S-DEB spanned concentrations of 20-6000, 34-8600 and 50-6000 μM, respectively. Intra- and interday precision and accuracy of the developed method fulfilled analytical criteria. The stability of the analytes in experimental samples was also established. The validated HPLC method was successfully applied to the investigation of the kinetics of TREO activation to S,S-EBDM and S,S-DEB. At pH 7.4 and 37 °C the transformation of TREO followed first-order kinetics with a half-life 1.5h. Copyright © 2012 Elsevier B.V. All rights reserved.

  12. Development, Validation and Application of a Stability Indicating HPLC Method to Quantify Lidocaine from Polyethylene-co-Vinyl Acetate (EVA) Matrices and Biological Fluids.

    PubMed

    Bhusal, Prabhat; Sharma, Manisha; Harrison, Jeff; Procter, Georgina; Andrews, Gavin; Jones, David S; Hill, Andrew G; Svirskis, Darren

    2017-09-01

    An efficient and cost-effective quantification procedure for lidocaine by HPLC has been developed to estimate lidocaine from an EVA matrix, plasma, peritoneal fluid and intra-articular fluid (IAF). This method guarantees the resolution of lidocaine from the degradation products obtained from alkaline and oxidative stress. Chromatographic separation of lidocaine was achieved with a retention time of 7 min using a C18 column with a mobile phase comprising acetonitrile and potassium dihydrogen phosphate buffer (pH 5.5; 0.02 M) in the ratio of 26:74 at a flow rate of 1 mL min-1 with detection at 230 nm. Instability of lidocaine was observed to an oxidizing (0.02% H2O2) and alkaline environments (0.1 M NaOH). The calibration curve was found to be linear within the concentration range of 0.40-50.0 μg/mL. Intra-day and inter-day accuracy ranged between 95.9% and 99.1%, with precision (% RSD) below 6.70%. The limit of quantification and limit of detection were 0.40 μg/mL and 0.025 μg/mL, respectively. The simple extraction method described enabled the quantification of lidocaine from an EVA matrix using dichloromethane as a solvent. The assay and content uniformity of lidocaine within an EVA matrix were 103 ± 3.60% and 100 ± 2.60%, respectively. The ability of this method to quantify lidocaine release from EVA films was also demonstrated. Extraction of lidocaine from plasma, peritoneal fluid and IAF followed by HPLC analysis confirmed the utility of this method for ex vivo and in vivo studies where the calibration plot was found to be linear from 1.60 to 50.0 μg/mL. © Crown copyright 2017.

  13. Test Score Stability and Construct Validity of the Adult Manifest Anxiety Scale-College Version Scores among College Students: A Brief Report

    ERIC Educational Resources Information Center

    Lowe, Patricia A.; Papanastasiou, Elena C.; DeRuyck, Kimberly A.; Reynolds, Cecil R.

    2005-01-01

    In this study, the authors investigated the temporal stability and construct validity of the Adult Manifest Anxiety Scale-College Version (AMAS-C; C. R. Reynolds, B. O. Richmond, & P. A. Lowe, 2003b) scores. Results indicated that the AMAS-C scores had adequate to excellent test score stability, and evidence supported the construct validity of the…

  14. 76 FR 55329 - Receipt of Several Pesticide Petitions Filed for Residues of Pesticide Chemicals in or on Various...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-09-07

    ... (HPLC) method was validated for determination of dinotefuran, DN and UF in or on tomatoes and peppers... quantified after HPLC separation by tandem mass spectrometry (MS/MS) detection. Contact: Sidney Jackson, (703..., group 9 at 0.03 ppm. Adequate analytical methods (HPLC-fluorescence methods) are available for...

  15. Best Practices in Stability Indicating Method Development and Validation for Non-clinical Dose Formulations.

    PubMed

    Henry, Teresa R; Penn, Lara D; Conerty, Jason R; Wright, Francesca E; Gorman, Gregory; Pack, Brian W

    2016-11-01

    Non-clinical dose formulations (also known as pre-clinical or GLP formulations) play a key role in early drug development. These formulations are used to introduce active pharmaceutical ingredients (APIs) into test organisms for both pharmacokinetic and toxicological studies. Since these studies are ultimately used to support dose and safety ranges in human studies, it is important to understand not only the concentration and PK/PD of the active ingredient but also to generate safety data for likely process impurities and degradation products of the active ingredient. As such, many in the industry have chosen to develop and validate methods which can accurately detect and quantify the active ingredient along with impurities and degradation products. Such methods often provide trendable results which are predictive of stability, thus leading to the name; stability indicating methods. This document provides an overview of best practices for those choosing to include development and validation of such methods as part of their non-clinical drug development program. This document is intended to support teams who are either new to stability indicating method development and validation or who are less familiar with the requirements of validation due to their position within the product development life cycle.

  16. Degradation of components in drug formulations: a comparison between HPLC and DSC methods.

    PubMed

    Ceschel, G C; Badiello, R; Ronchi, C; Maffei, P

    2003-08-08

    Information about the stability of drug components and drug formulations is needed to predict the shelf-life of the final products. The studies on the interaction between the drug and the excipients may be carried out by means of accelerated stability tests followed by analytical determination of the active principle (HPLC and other methods) and by means of the differential scanning calorimetry (DSC). This research has been focused to the acetyl salicylic acid (ASA) physical-chemical characterisation by using DSC method in order to evaluate its compatibility with some of the most used excipients. It was possible to show, with the DSC method, the incompatibility of magnesium stearate with ASA; the HPLC data confirm the reduction of ASA concentration in the presence of magnesium stearate. With the other excipients the characteristic endotherms of the drug were always present and no or little degradation was observed with the accelerated stability tests. Therefore, the results with the DSC method are comparable and in good agreement with the results obtained with other methods.

  17. HPLC analysis and standardization of Brahmi vati - An Ayurvedic poly-herbal formulation.

    PubMed

    Mishra, Amrita; Mishra, Arun K; Tiwari, Om Prakash; Jha, Shivesh

    2013-09-01

    The aim of the present study was to standardize Brahmi vati (BV) by simultaneous quantitative estimation of Bacoside A3 and Piperine adopting HPLC-UV method. BV very important Ayurvedic polyherbo formulation used to treat epilepsy and mental disorders containing thirty eight ingredients including Bacopa monnieri L. and Piper longum L. An HPLC-UV method was developed for the standardization of BV in light of simultaneous quantitative estimation of Bacoside A3 and Piperine, the major constituents of B. monnieri L. and P. longum L. respectively. The developed method was validated on parameters including linearity, precision, accuracy and robustness. The HPLC analysis showed significant increase in amount of Bacoside A3 and Piperine in the in-house sample of BV when compared with all three different marketed samples of the same. Results showed variations in the amount of Bacoside A3 and Piperine in different samples which indicate non-uniformity in their quality which will lead to difference in their therapeutic effects. The outcome of the present investigation underlines the importance of standardization of Ayurvedic formulations. The developed method may be further used to standardize other samples of BV or other formulations containing Bacoside A3 and Piperine.

  18. A novel reversed-phase HPLC method for the determination of urinary creatinine by pre-column derivatization with ethyl chloroformate: comparative studies with the standard Jaffé and isotope-dilution mass spectrometric assays.

    PubMed

    Leung, Elvis M K; Chan, Wan

    2014-02-01

    Creatinine is an important biomarker for renal function diagnosis and normalizing variations in urinary drug/metabolites concentration. Quantification of creatinine in biological fluids such as urine and plasma is important for clinical diagnosis as well as in biomonitoring programs and urinary metabolomics/metabonomics research. Current methods for creatinine determination either are nonselective or involve the use of expensive mass spectrometers. In this paper, a novel reversed-phase high-performance liquid chromatographic (HPLC) method for the determination of creatinine of high hydrophilicity by pre-column derivatization with ethyl chloroformate is presented. N-Ethyloxycarbonylation of creatinine significantly enhanced the hydrophobicity of creatinine, facilitating its chromatographic retention as well as quantification by HPLC. Factors governing the derivatization reaction were studied and optimized. The developed method was validated and applied for the determination of creatinine in rat urine samples. Comparative studies with isotope-dilution mass spectrometric method revealed that the two methods do not yield systematic differences in creatinine concentrations, indicating the HPLC method is suitable for the determination of creatinine in urine samples.

  19. Ratio manipulating spectrophotometry versus chemometry as stability indicating methods for cefquinome sulfate determination

    NASA Astrophysics Data System (ADS)

    Yehia, Ali M.; Arafa, Reham M.; Abbas, Samah S.; Amer, Sawsan M.

    2016-01-01

    Spectral resolution of cefquinome sulfate (CFQ) in the presence of its degradation products was studied. Three selective, accurate and rapid spectrophotometric methods were performed for the determination of CFQ in the presence of either its hydrolytic, oxidative or photo-degradation products. The proposed ratio difference, derivative ratio and mean centering are ratio manipulating spectrophotometric methods that were satisfactorily applied for selective determination of CFQ within linear range of 5.0-40.0 μg mL- 1. Concentration Residuals Augmented Classical Least Squares was applied and evaluated for the determination of the cited drug in the presence of its all degradation products. Traditional Partial Least Squares regression was also applied and benchmarked against the proposed advanced multivariate calibration. Experimentally designed 25 synthetic mixtures of three factors at five levels were used to calibrate and validate the multivariate models. Advanced chemometrics succeeded in quantitative and qualitative analyses of CFQ along with its hydrolytic, oxidative and photo-degradation products. The proposed methods were applied successfully for different pharmaceutical formulations analyses. These developed methods were simple and cost-effective compared with the manufacturer's RP-HPLC method.

  20. Development and validation of a new HPLC-UV method for the simultaneous determination of triclabendazole and ivermectin B1a in a pharmaceutical formulation.

    PubMed

    Shurbaji, Maher; Abu Al Rub, Mohamad H; Saket, Munib M; Qaisi, Ali M; Salim, Maher L; Abu-Nameh, Eyad S M

    2010-01-01

    A rapid, simple, and sensitive RP-HPLC analytical method was developed for the simultaneous determination of triclabendazole and ivermectin in combination using a C18 RP column. The mobile phase was acetonitrile-methanol-water-acetic acid (56 + 36 + 7.5 + 0.5, v/v/v/v) at a pH of 4.35 and flow rate of 1.0 mL/min. A 245 nm UV detection wavelength was used. Complete validation, including linearity, accuracy, recovery, LOD, LOQ, precision, robustness, stability, and peak purity, was performed. The calibration curve was linear over the range 50.09-150.26 microg/mL for triclabendazole with r = 0.9999 and 27.01-81.02 microg/mL for ivermectin with r = 0.9999. Calculated LOD and LOQ for triclabendazole were 0.03 and 0.08 microg/mL, respectively, and for ivermectin 0.07 and 0.20 microg/mL, respectively. The intraday precision obtained was 98.71% with RSD of 0.87% for triclabendazole and 100.79% with RSD 0.73% for ivermectin. The interday precision obtained was 99.51% with RSD of 0.35% for triclabendazole and 100.55% with RSD of 0.59% for ivermectin. Robustness was also studied, and there was no significant variation of the system suitability of the analytical method with small changes in experimental parameters.

  1. New validated method for piracetam HPLC determination in human plasma.

    PubMed

    Curticapean, Augustin; Imre, Silvia

    2007-01-10

    The new method for HPLC determination of piracetam in human plasma was developed and validated by a new approach. The simple determination by UV detection was performed on supernatant, obtained from plasma, after proteins precipitation with perchloric acid. The chromatographic separation of piracetam under a gradient elution was achieved at room temperature with a RP-18 LiChroSpher 100 column and aqueous mobile phase containing acetonitrile and methanol. The quantitative determination of piracetam was performed at 200 nm with a lower limit of quantification LLQ=2 microg/ml. For this limit, the calculated values of the coefficient of variation and difference between mean and the nominal concentration are CV%=9.7 and bias%=0.9 for the intra-day assay, and CV%=19.1 and bias%=-7.45 for the between-days assay. For precision, the range was CV%=1.8/11.6 in the intra-day and between-days assay, and for accuracy, the range was bias%=2.3/14.9 in the intra-day and between-days assay. In addition, the stability of piracetam in different conditions was verified. Piracetam proved to be stable in plasma during 4 weeks at -20 degrees C and for 36 h at 20 degrees C in the supernatant after protein precipitation. The new proposed method was used for a bioequivalence study of two medicines containing 800 mg piracetam.

  2. Spectrophotometric and HPLC determinations of anti-diabetic drugs, rosiglitazone maleate and metformin hydrochloride, in pure form and in pharmaceutical preparations.

    PubMed

    Onal, Armağan

    2009-12-01

    In this study, three spectrophotometric methods and one HPLC method were developed for analysis of anti-diabetic drugs in tablets. The two spectrophotometric methods were based on the reaction of rosiglitazone (RSG) with 2,3-dichloro-5,6-dicyano-1,4-benzoquinone (DDQ) and bromocresol green (BCG). Linear relationship between the absorbance at lambda(max) and the drug concentration was found to be in the ranges 6.0-50.0 and 1.5-12 microg ml(-1) for DDQ and BCG methods, respectively. The third spectrophotometric method consists of a zero-crossing first-derivative spectrophotometric method for simultaneous analysis of RSG and metformin (MTF) in tablets. The calibration curves were linear within the concentration ranges of 5.0-50 microg ml(-1) for RSG and 1.0-10.0 microg ml(-1) for MTF. The fourth method is a rapid stability-indicating HPLC method developed for the determination of RSG. A linear response was observed within the concentration range of 0.25-2.5 microg ml(-1). The proposed methods have been successfully applied to the tablet analysis.

  3. An integrated Taguchi and response surface methodological approach for the optimization of an HPLC method to determine glimepiride in a supersaturatable self-nanoemulsifying formulation.

    PubMed

    Dash, Rajendra Narayan; Mohammed, Habibuddin; Humaira, Touseef

    2016-01-01

    We studied the application of Taguchi orthogonal array (TOA) design during the development of an isocratic stability indicating HPLC method for glimepiride as per TOA design; twenty-seven experiments were conducted by varying six chromatographic factors. Percentage of organic phase was the most significant (p < 0.001) on retention time, while buffer pH had the most significant (p < 0.001) effect on tailing factor and theoretical plates. TOA design has shortcoming, which identifies the only linear effect, while ignoring the quadratic and interaction effects. Hence, a response surface model for each response was created including the linear, quadratic and interaction terms. The developed models for each response found to be well predictive bearing an acceptable adjusted correlation coefficient (0.9152 for retention time, 0.8985 for tailing factor and 0.8679 for theoretical plates). The models were found to be significant (p < 0.001) having a high F value for each response (15.76 for retention time, 13.12 for tailing factor and 9.99 for theoretical plates). The optimal chromatographic condition uses acetonitrile - potassium dihydrogen phosphate (pH 4.0; 30 mM) (50:50, v/v) as the mobile phase. The temperature, flow rate and injection volume were selected as 35 ± 2 °C, 1.0 mL min(-1) and 20 μL respectively. The method was validated as per ICH guidelines and was found to be specific for analyzing glimepiride from a novel supersaturatable self-nanoemulsifying formulation.

  4. Microwave-assisted extraction with water for fast extraction and simultaneous RP-HPLC determination of phenolic acids in radix Salviae Miltiorrhizae.

    PubMed

    Fang, Xinsheng; Wang, Jianhua; Zhou, Hongying; Jiang, Xingkai; Zhu, Lixiang; Gao, Xin

    2009-07-01

    An optimized microwave-assisted extraction method using water (MAE-W) as the extractant and an efficient HPLC analysis method were first developed for the fast extraction and simultaneous determination of D(+)-(3,4-dihydroxyphenyl) lactic acid (Dla), salvianolic acid B (SaB), and lithospermic acid (La) in radix Salviae Miltiorrhizae. The key parameters of MAE-W were optimized. It was found that the degradation of SaB was inhibited when using the optimized MAE-W and the stable content of Dla, La, and SaB in danshen was obtained. Furthermore, compared to the conventional extraction methods, the proposed MAE-W is a more rapid method with higher yield and lower solvent consumption with a reproducibility (RSD <6%). In addition, using water as extractant is safe and helpful for environment protection, which could be referred to as green extraction. The separation and quantitative determination of the three compounds was carried out by a developed reverse-phase high-performance liquid chromatographic (RP-HPLC) method with UV detection. Highly efficient separation was obtained using gradient solvent system. The optimized HPLC analysis method was validated to have specificity, linearity, precision, and accuracy. The results indicated that MAE-W followed by HPLC-UV determination is an appropriate alternative to previously proposed method for quality control of radix Salviae Miltiorrhizae.

  5. Development of a gradient HPLC method for the simultaneous determination of sotalol and sorbate in oral liquid preparations using solid core stationary phase.

    PubMed

    Matysova, Ludmila; Zahalkova, Oxana; Klovrzova, Sylva; Sklubalova, Zdenka; Solich, Petr; Zahalka, Lukas

    2015-01-01

    A selective and sensitive gradient HPLC-UV method for quantification of sotalol hydrochloride and potassium sorbate in five types of oral liquid preparations was developed and fully validated. The separation of an active substance sotalol hydrochloride, potassium sorbate (antimicrobial agent), and other substances (for taste and smell correction, etc.) was performed using an Ascentis Express C18 (100 × 4.6 mm, particles 2.7 μm) solid core HPLC column. Linear gradient elution mode with a flow rate of 1.3 mL min(-1) was used, and the injection volume was 5 µL. The UV/Vis absorbance detector was set to a wavelength of 237 nm, and the column oven was conditioned at 25°C. A sodium dihydrogen phosphate dihydrate solution (pH 2.5; 17.7 mM) was used as the mobile phase buffer. The total analysis time was 4.5 min (+2.5 min for reequilibration). The method was successfully employed in a stability evaluation of the developed formulations, which are now already being used in the therapy of arrhythmias in pediatric patients; the method is also suitable for general quality control, that is, not only just for extemporaneous preparations containing the mentioned substances.

  6. Development of a Gradient HPLC Method for the Simultaneous Determination of Sotalol and Sorbate in Oral Liquid Preparations Using Solid Core Stationary Phase

    PubMed Central

    2015-01-01

    A selective and sensitive gradient HPLC-UV method for quantification of sotalol hydrochloride and potassium sorbate in five types of oral liquid preparations was developed and fully validated. The separation of an active substance sotalol hydrochloride, potassium sorbate (antimicrobial agent), and other substances (for taste and smell correction, etc.) was performed using an Ascentis Express C18 (100 × 4.6 mm, particles 2.7 μm) solid core HPLC column. Linear gradient elution mode with a flow rate of 1.3 mL min−1 was used, and the injection volume was 5 µL. The UV/Vis absorbance detector was set to a wavelength of 237 nm, and the column oven was conditioned at 25°C. A sodium dihydrogen phosphate dihydrate solution (pH 2.5; 17.7 mM) was used as the mobile phase buffer. The total analysis time was 4.5 min (+2.5 min for reequilibration). The method was successfully employed in a stability evaluation of the developed formulations, which are now already being used in the therapy of arrhythmias in pediatric patients; the method is also suitable for general quality control, that is, not only just for extemporaneous preparations containing the mentioned substances. PMID:25878920

  7. Simultaneous quantification of metronidazole, tinidazole, ornidazole and morinidazole in human saliva.

    PubMed

    Wang, Yongqing; Zhang, Peipei; Jiang, Ningling; Gong, Xiaojian; Meng, Ling; Wang, Dewang; Ou, Ning; Zhang, Haibo

    2012-06-15

    The aim of this study was to develop a rapid and sensitive method for the simultaneous quantification of metronidazole (MEZ), tinidazole (TNZ), ornidazole (ONZ) and morinidazole (MNZ) in human saliva. A reversed-phase high-performance liquid chromatography (HPLC) method with ultraviolet (UV) detection at 318 nm was carried out on a C18 column, using a mixture of potassium dihydrogen phosphate buffer, acetonitrile, and methanol (55:15:30, v/v/v) as a mobile phase with a flow rate of 1.0 ml/min. The saliva samples (100 μl) were firstly deproteinized by precipitation with methanol (400 μl), after which they were centrifuged and the supernatants were directly injected into the HPLC system. This method produced linear responses in the concentration ranges of 25.2-5040.0, 23.9-4790.0, 25.4-5080.0, 25.0-5000.0 ng/ml with detection limits of 6.0, 17.6, 10.0 and 11.3 ng/ml for MEZ, TNZ, ONZ and MNZ (S/N=3), respectively. The methods were validated in terms of intra- and inter-batch precision (within 7.3% and 9.1%, respectively), accuracy, linearity, recovery and stability. The study proved that HPLC is both sensitive and selective for the simultaneous quantification of MEZ, TNZ, ONZ and MNZ in human saliva using a single mobile phase. Copyright © 2012 Elsevier B.V. All rights reserved.

  8. A simple HPLC-DAD method for simultaneous detection of two organophosphates, profenofos and fenthion, and validation by soil microcosm experiment.

    PubMed

    Mahajan, Rishi; Chatterjee, Subhankar

    2018-05-05

    Indiscriminate use of two broad spectrum pesticides, profenofos and fenthion, in agricultural system, often results in their accumulation in a non-target niche and leaching into water bodies. The present study, therefore, aims at developing a simple and rapid HPLC method that allows simultaneous extraction and detection of these two pesticides, especially in run-off water. Extraction of the two pesticides from spiked water samples using dichloromethane resulted in recovery ranging between 80 and 90%. An HPLC run of 20 min under optimized chromatographic parameters (mobile phase: methanol (75%) and water (25%); flow rate of 0.8 ml min -1 ; diode array detector at wavelength 210 nm) resulted in a significant difference in retention times of two pesticides (4.593 min) which allows a window of opportunity to study any possible intermediates/transformants of the parent compounds while evaluating run-off waters from agricultural fields. The HPLC method developed allowed simultaneous detection of profenofos and fenthion with a single injection into the HPLC system with 0.0328 mg l -1 (32.83 ng ml -1 ) being the limit of detection (LOD) and 0.0995 mg l -1 (99.5 ng ml -1 ) as the limit of quantification (LOQ) for fenthion; for profenofos, LOD and LOQ were 0.104 mg l -1 (104.50 ng ml -1 ) and 0.316 mg l -1 (316.65 ng ml -1 ), respectively. The findings were further validated using the soil microcosm experiment that allowed simultaneous detection and quantification of profenofos and fenthion. The findings indicate towards the practical significance of the methodology developed as the soil microcosm experiment closely mimics the agricultural run-off water under natural environmental conditions.

  9. A rapid stability-indicating, fused-core HPLC method for simultaneous determination of β-artemether and lumefantrine in anti-malarial fixed dose combination products

    PubMed Central

    2013-01-01

    Background Artemisinin-based fixed dose combination (FDC) products are recommended by World Health Organization (WHO) as a first-line treatment. However, the current artemisinin FDC products, such as β-artemether and lumefantrine, are inherently unstable and require controlled distribution and storage conditions, which are not always available in resource-limited settings. Moreover, quality control is hampered by lack of suitable analytical methods. Thus, there is a need for a rapid and simple, but stability-indicating method for the simultaneous assay of β-artemether and lumefantrine FDC products. Methods Three reversed-phase fused-core HPLC columns (Halo RP-Amide, Halo C18 and Halo Phenyl-hexyl), all thermostated at 30°C, were evaluated. β-artemether and lumefantrine (unstressed and stressed), and reference-related impurities were injected and chromatographic parameters were assessed. Optimal chromatographic parameters were obtained using Halo RP-Amide column and an isocratic mobile phase composed of acetonitrile and 1mM phosphate buffer pH 3.0 (52:48; V/V) at a flow of 1.0 ml/min and 3 μl injection volume. Quantification was performed at 210 nm and 335 nm for β-artemether and for lumefantrine, respectively. In-silico toxicological evaluation of the related impurities was made using Derek Nexus v2.0®. Results Both β-artemether and lumefantrine were separated from each other as well as from the specified and unspecified related impurities including degradants. A complete chromatographic run only took four minutes. Evaluation of the method, including a Plackett-Burman robustness verification within analytical QbD-principles, and real-life samples showed the method is suitable for quantitative assay purposes of both active pharmaceutical ingredients, with a mean recovery relative standard deviation (± RSD) of 99.7 % (± 0.7%) for β-artemether and 99.7 % (± 0.6%) for lumefantrine. All identified β-artemether-related impurities were predicted in Derek Nexus v2.0® to have toxicity risks similar to β-artemether active pharmaceutical ingredient (API) itself. Conclusions A rapid, robust, precise and accurate stability-indicating, quantitative fused-core isocratic HPLC method was developed for simultaneous assay of β-artemether and lumefantrine. This method can be applied in the routine regulatory quality control of FDC products. The in-silico toxicological investigation using Derek Nexus® indicated that the overall toxicity risk for β-artemether-related impurities is comparable to that of β-artemether API. PMID:23631682

  10. Space Environment Effects on Stability of Medications Flown on Space Shuttles and the International Space Station (ISS)

    NASA Technical Reports Server (NTRS)

    Daniels, Vernie; Du, Jianping; Crady, Camille; Satterfield, Rick; Putcha, Lakshmi

    2007-01-01

    The purpose is to assess physical and chemical degradation of select pharmaceutical formulations from the Shuttle and ISS medical kits. Eleven pharmaceuticals dispensed as different dosage forms were selected based on their physical / chemical characteristics and susceptibility to environmental factors such as, temperature, humidity and light sensitivity. When available, ground-controls of the study medications with matching brand and lot numbers were used for comparison. Samples retrieved from flight were stored along with their matching controls in a temperature and humidity controlled environmental chamber. Temperature, humidity, and radiation data from the Shuttle and ISS were retrieved from onboard HOBO U12 Temp/RH Data Loggers, and from passive dosimeters. Physical and chemical analyses of the pharmaceuticals were conducted using validated United States Pharmacopeia (USP) methods. Results indicated degradation of 6 of the 11 formulations returned from space flights. Four formulations, Amoxicillin / Clavulanate, promethazine, sulfamethoxazole / trimethoprim, and ciprofloxacin tablets depicted discoloration after flight. Chemical content analyses using High or Ultra Performance Liquid Chromatography (HPLC / UPLC) methods revealed that dosage forms of Amoxicillin / Clavulanate, promethazine, sulfamethoxazole / trimethoprim, lidocaine, ciprofloxacin and mupirocin contained less than 95% of manufacturer s labeled claim of active drug compound. Shuttle and ISS environments affect stability and shelf life of certain mediations flown on these missions. Data analysis is in progress to examine the effect of specific space flight environmental factors on pharmaceutical stability. The degradation profiles generated from ground studies in analog environments will be useful in establishing predictive shelf-life profiles for medications intended for use during long-term space exploration missions.

  11. Long-Term Stability of Tramadol and Ketamine Solutions for Patient-Controlled Analgesia Delivery.

    PubMed

    Gu, Junfeng; Qin, Wengang; Chen, Fuchao; Xia, Zhongyuan

    2015-08-26

    Subanesthetic doses of ketamine as an adjuvant to tramadol in patient-controlled analgesia (PCA) for postoperative pain have been shown to improve the quality of analgesia. However, there are no such commercially available drug mixtures, and the stability of the combination has rarely been assessed. Admixtures were assessed for periods of up to 14 days at 4°C and 25°C. Three different mixtures of tramadol and ketamine (tramadol 5.0 mg/mL + ketamine 0.5 mg/mL, tramadol 5.0 mg/mL + ketamine 1.0 mg/mL, and tramadol 5.0 mg/mL + ketamine 2.0 mg/mL) were prepared in polyolefin bags by combining these 2 drugs with 0.9% sodium chloride (normal saline [NS]). The chemical stability of the admixtures was evaluated by a validated high-performance liquid chromatography (HPLC) method and by measurement of pH values. Solution appearance and color were assessed by observing the samples against black and white backgrounds. Solutions were considered stable if they maintained 90% of the initial concentration of each drug. The percentages of initial concentration of tramadol and ketamine in the various solutions remained above 98% when stored at 4°C or 25°C over the testing period. No changes in color or turbidity were observed in any of the prepared solutions. Throughout this period, pH values remained stable. The results indicate that the drug mixtures of tramadol with ketamine in NS for PCA delivery systems were stable for 14 days when stored in polyolefin bags at 4°C or 25°C.

  12. Validation of a method for the quantitation of ghrelin and unacylated ghrelin by HPLC.

    PubMed

    Staes, Edith; Rozet, Eric; Ucakar, Bernard; Hubert, Philippe; Préat, Véronique

    2010-02-05

    An HPLC/UV method was first optimized for the separation and quantitation of human acylated and unacylated (or des-acyl) ghrelin from aqueous solutions. This method was validated by an original approach using accuracy profiles based on tolerance intervals for the total error measurement. The concentration range that achieved adequate accuracy extended from 1.85 to 59.30microM and 1.93 to 61.60microM for acylated and unacylated ghrelin, respectively. Then, optimal temperature, pH and buffer for sample storage were determined. Unacylated ghrelin was found to be stable in all conditions tested. At 37 degrees C acylated ghrelin was stable at pH 4 but unstable at pH 7.4, the main degradation product was unacylated ghrelin. Finally, this validated HPLC/UV method was used to evaluate the binding of acylated and unacylated ghrelin to liposomes.

  13. Validation of an HPLC-UV method for the determination of ceftriaxone sodium residues on stainless steel surface of pharmaceutical manufacturing equipments.

    PubMed

    Akl, Magda A; Ahmed, Mona A; Ramadan, Ahmed

    2011-05-15

    In pharmaceutical industry, an important step consists in the removal of possible drug residues from the involved equipments and areas. The cleaning procedures must be validated and methods to determine trace amounts of drugs have, therefore, to be considered with special attention. An HPLC-UV method for the determination of ceftriaxone sodium residues on stainless steel surface was developed and validated in order to control a cleaning procedure. Cotton swabs, moistened with extraction solution (50% water and 50% mobile phase), were used to remove any residues of drugs from stainless steel surfaces, and give recoveries of 91.12, 93.8 and 98.7% for three concentration levels. The precision of the results, reported as the relative standard deviation (RSD), were below 1.5%. The method was validated over a concentration range of 1.15-6.92 μg ml(-1). Low quantities of drug residues were determined by HPLC-UV using a Hypersil ODS 5 μm (250×4.6 mm) at 50 °C with an acetonitrile:water:pH 7:pH 5 (39-55-5.5-0.5) mobile phase at flow rate of 1.5 ml min(-1), an injection volume of 20 μl and were detected at 254 nm. A simple, selective and sensitive HPLC-UV assay for the determination of ceftriaxone sodium residues on stainless steel surfaces was developed, validated and applied. Copyright © 2011 Elsevier B.V. All rights reserved.

  14. The use of capillary electrophoresis as part of a specificity testing strategy for mitoguazone dihydrochloride HPLC methods.

    PubMed

    Thomson, C E; Gray, M R; Baxter, M P

    1997-05-01

    Capillary electrophoresis (CE) has been used as part of a validation experiment designed to prove the specificity of high performance liquid chromatography (HPLC) methods used for analysis of mitoguazone dihydrochloride drug substance. Data regarding accuracy, precision and sensitivity of the CE methods are presented as well as a comparison of results obtained from CE, HPLC and thin-layer chromatography (TLC) analysis of samples stressed under a variety of conditions. It was concluded that, not only were the HPLC methods being investigated specific, but that CE could potentially be used to replace HPLC for the routine assay of mitoguazone dihydrochloride.

  15. Validation of a Reversed-Phase High Performance Liquid Chromatography Method for the Simultaneous Analysis of Cysteine and Reduced Glutathione in Mouse Organs

    PubMed Central

    Brundu, Serena; Nencioni, Lucia; Celestino, Ignacio; Coluccio, Paolo; Palamara, Anna Teresa; Fraternale, Alessandra

    2016-01-01

    A depletion of reduced glutathione (GSH) has been observed in pathological conditions and in aging. Measuring GSH in tissues using mouse models is an excellent way to assess GSH depletion and the potential therapeutic efficacy of drugs used to maintain and/or restore cellular redox potential. A high performance liquid chromatography (HPLC) method for the simultaneous determination of GSH and cysteine (Cys) in mouse organs was validated according to USA and European standards. The method was based on separation coupled with ultraviolet detection and precolumn derivatization with 5,5′-dithiobis-(2-nitrobenzoic acid) (DTNB). The required validation parameters, that are, selectivity, linearity, lower limit of quantification, precision, accuracy, recovery, and stability, were studied for spleen, lymph nodes, pancreas, and brain. The results showed that the lower limits of quantification were 0.313 μM and 1.25 μM for Cys and GSH, respectively. Intraday and interday precisions were less than 11% and 14%, respectively, for both compounds. The mean extraction recoveries of Cys and GSH from all organs were more than 93% and 86%, respectively. Moreover, the stability of both analytes during sample preparation and storage was demonstrated. The method was accurate, reliable, consistent, and reproducible and it was useful to determine Cys and GSH in the organs of different mouse strains. PMID:26885246

  16. A simple HPLC method for the comprehensive analysis of cis/trans (Z/E) geometrical isomers of carotenoids for nutritional studies

    USDA-ARS?s Scientific Manuscript database

    Geometrical isomers of carotenoids behave differently in aspects like stability towards oxidants, bioavailability, vitamin A activity and specificity for enzymes. The availability of HPLC methods for their detailed profiling is therefore advisable to expand our knowledge on their metabolism and biol...

  17. Stability of amoxicillin-clavulanate in BACTEC medium determined by high-performance liquid chromatography and bioassay.

    PubMed Central

    Moore, T D; Horton, R; Utrup, L J; Miller, L A; Poupard, J A

    1996-01-01

    The stabilities of amoxicillin (16 micrograms/ml) and clavulanate (8 micrograms/ml), alone and in combination in BACTEC medium (Middlebrook 7H12B medium), were determined by high-performance liquid chromatography (HPLC) and bioassay. By HPLC, the half-life of amoxicillin (trihydrate and sodium) in combination with clavulanate in nonradiolabelled 7H12B medium was 6.7 days, whereas the half-life of clavulanate in combination with amoxicillin was 2.0 days. By bioassay, the half-lives of amoxicillin trihydrate and clavulanate in radiolabelled 7H12B medium were comparable (7 and 2 days, respectively) to those determined by HPLC. When clavulanate was tested alone, the half-life was determined to be 1.88 days by HPLC and 1.87 days by bioassay. The relatively short half-life of clavulanate can be adjusted by a procedure of "topping up," or adding one-half the concentration of clavulanate every second day, in order to allow accurate amoxicillin-clavulanate MIC testing with the BACTEC mycobacterial susceptibility system. PMID:8727931

  18. Microchip electrospray: improvements in spray and signal stability during gradient elution by an inverted postcolumn makeup flow.

    PubMed

    Jung, Stephanie; Effelsberg, Uwe; Tallarek, Ulrich

    2011-12-01

    Dynamic changes in mobile phase composition during high-performance liquid chromatography (HPLC) gradient elution coupled to mass spectrometry (MS) sensitively affect electrospray modes. We investigate the impact of the eluent composition on spray stability and MS response by infusion and injection experiments with a small tetrapeptide in water-acetonitrile mixtures. The employed HPLC/electrospray (ESI)-MS configuration uses a microchip equipped with an enrichment column, a separation column, and a makeup flow (MUF) channel. One nano pump is connected to the separation column, while a second one delivers solvent of exactly inverted composition to the MUF channel. Both solvent streams are united behind the separation column, before the ESI tip, such that the resulting electrosprayed solution always has identical composition during a gradient elution. Analyte peak parameters without and with MUF compensation are determined and discussed with respect to the electrospray mode and eluent composition. The postcolumn MUF significantly improves spray and signal stability over the entire solvent gradient, without compromising the performance of the HPLC separation column. It can also be conveniently implemented on microchip platforms.

  19. An Investigation Into HPLC Data Quality Problems

    NASA Technical Reports Server (NTRS)

    Hooker, Stanford B.; VanHeukelem, Laurie

    2011-01-01

    This report summarizes the analyses and results produced by a five-member investigative team of Government, university, and industry experts, established by NASA HQ. The team examined data quality problems associated with high performance liquid chromatography (HPLC) analyses of pigment concentrations in seawater samples produced by the San Diego State University (SDSU) Center for Hydro-Optics and Remote Sensing (CHORS). This report shows CHORS did not validate the methods used before placing them into service to analyze field samples for NASA principal investigators (PIs), even though the HPLC literature contained easily accessible method validation procedures, and the importance of implementing them, more than a decade ago. In addition, there were so many sources of significant variance in the CHORS methodologies, that the HPLC system rarely operated within performance criteria capable of producing the requisite data quality. It is the recommendation of the investigative team to a) not correct the data, b) make all the data that was temporarily sequestered available for scientific use, and c) label the affected data with an appropriate warning, e.g., "These data are not validated and should not be used as the sole basis for a scientific result, conclusion, or hypothesis--independent corroborating evidence is required."

  20. Development and Validation of HPLC-DAD and UHPLC-DAD Methods for the Simultaneous Determination of Guanylhydrazone Derivatives Employing a Factorial Design.

    PubMed

    Azevedo de Brito, Wanessa; Gomes Dantas, Monique; Andrade Nogueira, Fernando Henrique; Ferreira da Silva-Júnior, Edeildo; Xavier de Araújo-Júnior, João; Aquino, Thiago Mendonça de; Adélia Nogueira Ribeiro, Êurica; da Silva Solon, Lilian Grace; Soares Aragão, Cícero Flávio; Barreto Gomes, Ana Paula

    2017-08-30

    Guanylhydrazones are molecules with great pharmacological potential in various therapeutic areas, including antitumoral activity. Factorial design is an excellent tool in the optimization of a chromatographic method, because it is possible quickly change factors such as temperature, mobile phase composition, mobile phase pH, column length, among others to establish the optimal conditions of analysis. The aim of the present work was to develop and validate a HPLC and UHPLC methods for the simultaneous determination of guanylhydrazones with anticancer activity employing experimental design. Precise, exact, linear and robust HPLC and UHPLC methods were developed and validated for the simultaneous quantification of the guanylhydrazones LQM10, LQM14, and LQM17. The UHPLC method was more economic, with a four times less solvent consumption, and 20 times less injection volume, what allowed better column performance. Comparing the empirical approach employed in the HPLC method development to the DoE approach employed in the UHPLC method development, we can conclude that the factorial design made the method development faster, more practical and rational. This resulted in methods that can be employed in the analysis, evaluation and quality control of these new synthetic guanylhydrazones.

  1. Development and application of a validated stability-indicating HPLC method for simultaneous determination of granisetron hydrochloride, benzyl alcohol and their main degradation products in parenteral dosage forms.

    PubMed

    Hewala, Ismail; El-Fatatre, Hamed; Emam, Ehab; Mubrouk, Mokhtar

    2010-06-30

    A simple, rapid and sensitive reversed phase high performance liquid chromatographic method using photodiode array detection was developed and validated for the simultaneous determination of granisetron hydrochloride, benzyl alcohol, 1-methyl-1H-indazole-3-carboxylic acid (the main degradation product of granisetron) and benzaldehyde (the main degradation product of benzyl alcohol) in granisetron injections. The separation was achieved on Hypersil BDS C8 (250 mm x 4.6 mm i.d., 5 microm particle diameter) column using a mobile phase consisted of acetonitrile:0.05 M KH(2)PO(4):triethylamine (22:100:0.15) adjusted to pH 4.8. The column was maintained at 25 degrees C and 20 microL of solutions was injected. Photodiode array detector was used to test the peak purity and the chromatograms were extracted at 210 nm. Naphazoline hydrochloride was used as internal standard. The method was validated with respect to specificity, linearity, accuracy, precision, limit of quantitation and limit of detection. The validation acceptance criteria were met in all cases. Identification of the pure peaks was carried out using library match programmer and wavelengths of derivative optima of the spectrograms of the peaks. The method was successfully applied to the determination of the investigated drugs and their degradation products in different batches of granisetron injections. The method was proved to be sensitive for the determination down to 0.03 and 0.01% of granisetron degradation product and benzaldehyde, respectively, which are far below the compendia limits for testing these degradation products in their corresponding intact drugs. Copyright 2010 Elsevier B.V. All rights reserved.

  2. An HPLC/UV method for the determination of RGH-1756 in dog and rat plasma.

    PubMed

    Terjéki, E; Kapás, M

    2001-03-01

    RGH-1756 (1-(2-methoxy-phenyl)-4-(4-[4-(6-imidazo[2,1-b]-thiazolyl)-phenoxy]-butyl)-piperazine dimethansulphonate) is a novel atypical antipsychotic candidate of Gedeon Richter Ltd. A new HPLC method has been developed and validated for the quantitative determination of RGH-1756 in dog and rat plasma. The compound and the internal standard are extracted from the biological samples by a simple and fast liquid--liquid extraction method, using 1-chlorobutane. The recovery for RGH-1756 is about 90%. The extracts are analyzed by reversed phase HPLC (column: Supelcosil-LC-18-DB 250*4.6 mm, 5 microm, eluent:acetonitrile:methanol:0.2 molar ammonium-acetate 40:25:35, lambda=254 nm). The assay is specific for RGH-1756. The standard curves are linear in the range between 10 and 2000 ng ml(-1). The overall precision (expressed as CV%) and accuracy (expressed as bias%) of quality controls and calibration standards are within 15%. The validated lower limit of quantification is 10 ng/ml. No indications have been found for possible instabilities of RGH-1756 in plasma, in the extraction solvent, or after repeated thawing-freezing cycles. The method has been succesfully applied for the bioavailability studies of RGH-1756 in the two animal species. In these studies results of the inprocess method validation have shown the reliability of the method, too. CV% of quality controls in the rat study has been found between 7.4 and 10.0%, in the dog study between 4.1 and 12.5%. The bias has ranged from 0.4 to 3.8% and from -4.5 to 1.2% in the rat and dog study, respectively.

  3. Development and validation of an HPLC method for simultaneous determination of trimethoprim and sulfamethoxazole in human plasma.

    PubMed

    Sayar, Esin; Sahin, Selma; Cevheroglu, Semsettin; Hincal, A Atilla

    2010-09-01

    The combination of trimethoprim (TMP) and sulfamethoxazole (SMX) is used in the treatment of many common infections such as urinary, respiratory and gastrointestinal tract infections. The aim of this study was to determine TMP and SMX simultaneously in human plasma samples by high performance liquid chromatography (HPLC) using antipyrine as the internal standard. Separation of the compounds was achieved on a reverse-phase C8 column packed with 5 microm dimethyl octadecylsilyl bonded amorphous silica (4.6 mm x 250 mm) column using a mobile phase consisted of potassium hydrogen phosphate, acetonitrile, methanol and water adjusted to pH 6.2. The mobile phase was delivered at a flow rate of 1 mL min- and the effluent was monitored using Max plot technique at 25 derees C. Retention times were 5 min for TMP, 7 min for antipyrine and 9 min for SMX. Quantitation limits were 10 ng mL(-1) for TMP and 50 ng mL(-1) for SMX. Our findings indicated that the developed HPLC method was precise, accurate, specific and sensitive for simultaneous determination of TMP and SMX. Proposed HPLC method was successfully applied for the analysis of TMP and SMX in human plasma after oral administration of a co-trimoxazole tablet to human volunteers.

  4. Development and Validation of a Simple and Rapid UPLC-MS Assay for Valproic Acid and Its Comparison With Immunoassay and HPLC Methods.

    PubMed

    Zhao, Mingming; Li, Guofei; Qiu, Feng; Sun, Yaxin; Xu, Yinghong; Zhao, Limei

    2016-04-01

    Valproic acid (VPA), a widely used antiepileptic drug, has a narrow therapeutic range of 50-100 mcg/mL and shows large individual variability. It is very important to monitor the trough concentration of VPA using a reliable method. Therefore, the aim of this study was to develop and validate a rapid ultraperformance liquid chromatographic-mass spectrometry (UPLC-MS) method for quantification of VPA in human serum and to compare with fluorescence polarization immunoassay (FPIA), chemiluminescence microparticle immunoassay (CMIA), and high-performance liquid chromatography (HPLC) methods. The method included extraction of VPA in serum by deproteinization with acetonitrile. The analysis was performed using an EC-C18 column (2.7 μm, 4.6 × 50 mm) under isocratic conditions with a mobile phase of acetonitrile/water (containing 0.1% formic acid) (45/55, vol/vol) at a flow rate of 0.6 mL/min. The detection was performed on a triple-quadrupole tandem mass spectrometer using an electrospary probe in the negative ionization mode. The method was validated by studies of selectivity, linearity, lower limit of quantification, accuracy, precision, recovery, matrix effect, and stability. Furthermore, all the 4 methods including FPIA, CMIA, and HPLC were subsequently used to assay the VPA concentration in 498 clinical serum samples collected from patients who received VPA. These methods were compared by Deming regression and Bland-Altman analysis. The retention time of VPA was 2.09 minutes. The calibration curve was linear over the concentration range of 1-200 mcg/mL, with a lower limit of quantification of 1 mcg/mL. The interday and intraday precision (RSD %) was less than 4.6% and 4.5%, respectively, and the accuracy (RE %) was below 7.9%. The recoveries and matrix effect of VPA at concentrations of 2, 50, and 160 mcg/mL met the requirement for the analysis of biological samples. No obvious degradation of VPA was observed under various storage conditions including room temperature for 12 hour, 3 freeze-thaw cycles, and -20°C for 3 months. Regression analysis showed that the correlation coefficients for the UPLC-MS versus FPIA, CMIA, and HPLC were 0.989, 0.988, and 0.987, respectively. The results of agreement tests between UPLC-MS and other methods showed that the mean difference of UPLC-MS and FPIA was -1.4 mcg/mL and 95% confidence interval of -7.7 to 4.9 mcg/mL, and the values for UPLC-MS and CMIA were -0.8 mcg/mL and -7.5 to 5.8 mcg/mL, for UPLC-MS and HPLC were 1.1 mcg/mL and -5.7 to 7.9 mcg/mL. The rapid UPLC-MS method we developed showed a good analytical performance required for therapeutic drug monitoring, leading to potential improvements in patient care and laboratory management. Compared with the FPIA, CMIA, and HPLC methods, the UPLC-MS method correlated well and displayed comparable VPA concentrations.

  5. Measurement of menadione in urine by HPLC

    USDA-ARS?s Scientific Manuscript database

    Mammals convert phylloquinone to MK-4, with menadione as a possible intermediate. We developed and validated a method measuring urinary menadione. A high performance liquid chromatography (HPLC) method with a C30 column, fluorescence detection and post-column zinc reduction was developed. The mobile...

  6. Validation of GC and HPLC systems for residue studies

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Williams, M.

    1995-12-01

    For residue studies, GC and HPLC system performance must be validated prior to and during use. One excellent measure of system performance is the standard curve and associated chromatograms used to construct that curve. The standard curve is a model of system response to an analyte over a specific time period, and is prima facia evidence of system performance beginning at the auto sampler and proceeding through the injector, column, detector, electronics, data-capture device, and printer/plotter. This tool measures the performance of the entire chromatographic system; its power negates most of the benefits associated with costly and time-consuming validation ofmore » individual system components. Other measures of instrument and method validation will be discussed, including quality control charts and experimental designs for method validation.« less

  7. Development and validation of an HPLC method for the determination of ten sulfonamide residues in milk according to 2002/657/EC.

    PubMed

    Tolika, Evanthia P; Samanidou, Victoria F; Papadoyannis, Ioannis N

    2011-07-01

    A HPLC method with diode-array detection, at 265 nm, was developed and validated for the determination of ten sulfonamides (SAs): sulfadiazine (SDZ), sulfathiazine (STZ), sulfamethoxine (SMTH), sulfamethizole (SMZ), sulfamethoxypyridazine (SMPZ), sulfamonomethoxine (SMMX), sulfamethoxazole (SMXZ), sulfisoxazole (SIX), sulfadimethoxine (SDMX), and sulfaquinoxaline (SQX) in milk. A mixture of ethyl acetate, n-hexane, and isopropanol was used for the extraction of target analytes from milk. The mobile phase, a mixture of 0.1% v/v formic acid, CH(3) CN, and CH(3) OH was delivered to the analytical column under a gradient program. The procedure was validated according to the European Union regulation 2002/657/EC in terms of selectivity, stability, decision limit, detection capability, accuracy, and precision. Mean recoveries of sulfonamides from milk samples spiked at three concentration levels (0.5×MRL, 1×MRL, and 1.5×MRL) (MRL, maximum residue level) were 93.9-115.9% for SDZ, 97.8-102.9% for STZ, 94.6-107.0% for SMTH, 98.3-111.5% for SMZ, 95.3-108.4% for SMPZ, 97.9-106.0% for SMMX, 97.6-111.3% for SMXZ, 94.3-104.6% for SIX, 96.4-109.1% for SDMX, and 98.2-111.2% for SQX. All RSD values were lower than 8.8%. The decision limits CCa calculated by spiking 20 blank milk samples at MRL (100 μg/kg) ranged from 101.61 to 106.84 μg/kg, whereas the detection capability CCb ranged from 105.64 to 119.01 μg/kg. Copyright © 2011 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  8. Validation of 64Cu-DOTA-rituximab injection preparation under good manufacturing practices: a PET tracer for imaging of B-cell non-Hodgkin lymphoma.

    PubMed

    Natarajan, Arutselvan; Arksey, Natasha; Iagaru, Andrei; Chin, Frederick T; Gambhir, Sanjiv Sam

    2015-01-01

    Manufacturing of 64Cu-1,4,7,10-tetraazacyclododecane-N,N',N'',N'''-tetraacetic acid (DOTA)-rituximab injection under good manufacturing practices (GMP) was validated for imaging of patients with CD20+ B-cell non-Hodgkin lymphoma. Rituximab was purified by size exclusion high performance liquid chromatography (HPLC) and conjugated to DOTA-mono-(N-hydroxysuccinimidyl) ester. 64CuCl2, buffers, reagents, and other raw materials were obtained as high-grade quality. Following a semi-automated synthesis of 64Cu-DOTA-rituximab, a series of quality control tests was performed. The product was further tested in vivo using micro-positron emission tomography/computed tomography (PET/CT) to assess targeting ability towards human CD20 in transgenic mice. Three batches of 64Cu-DOTA-rituximab final product were prepared as per GMP specifications. The radiolabeling yield from these batches was 93.1 ± 5.8%; these provided final product with radiopharmaceutical yield, purity, and specific activity of 59.2 ± 5.1% (0.9 ± 0.1 GBq of 64Cu), > 95% (by HPLC and radio-thin layer chromatography), and 229.4 ± 43.3 GBq/µmol (or 1.5 ± 0.3 MBq/µg), respectively. The doses passed apyrogenicity and human serum stability specifications, were sterile up to 14 days, and retained > 60% immunoreactivity. In vivo micro-PET/CT mouse images at 24 hours postinjection showed that the tracer targeted the intended sites of human CD20 expression. Thus, we have validated the manufacturing of GMP grade 64Cu-DOTA-rituximab for injection in the clinical setting.

  9. Development and validation of an HPLC method for the determination of dibenzoylmethane in rat plasma and its application to the pharmacokinetic study.

    PubMed

    Shen, Guoxiang; Hong, Jin-Liern; Kong, Ah-Ng Tony

    2007-06-01

    A highly sensitive and simple high-performance liquid chromatographic (HPLC) assay has been developed and validated for the quantification of dibenzoylmethane (DBM) in rat plasma. DBM and internal standard (I.S.) 1-(5-chloro-2-hydroxy-4-methylphenyl)-3-phenyl-1,3-propanedione (CHMPP) were extracted from rat plasma by ethyl acetate/methanol (95:5, v/v) and analyzed using reverse-phase gradient elution with a Phenomenex Gemini C18 5-mum column. A gradient of mobile phase (mobile phase A: water/methanol (80:20, v/v) with 0.1% TFA and mobile phase B: acetonitrile with 0.1% TFA) at a flow rate of 0.2 mL/min, and ultraviolet (UV) detection at 335 nm were utilized. The lower limit of quantification (LLOQ) using 50 microL rat plasma was 0.05 microg/mL. The calibration curve was linear over a concentration range of 0.05-20 microg/mL. The mean recoveries were 80.6+/-5.7, 83.4+/-1.6 and 77.1+/-3.4% with quality control (QC) level of 0.05, 1 and 20 microg/mL, respectively. Intra- and inter-day assay accuracy and precision fulfilled US FDA guidance for industry bioanalytical method validation. Stability studies showed that DBM was stable in rat plasma after 4h incubation at room temperature, one month storage at -80 degrees C and three freeze/thaw cycles, as well as in reconstitute buffer for 48 h at 4 degrees C. The utility of the assay was confirmed by the successful analysis of plasma samples from DBM pharmacokinetics studies in the rats after oral and intravenous administrations.

  10. The validity and reliability of a dynamic neuromuscular stabilization-heel sliding test for core stability.

    PubMed

    Cha, Young Joo; Lee, Jae Jin; Kim, Do Hyun; You, Joshua Sung H

    2017-10-23

    Core stabilization plays an important role in the regulation of postural stability. To overcome shortcomings associated with pain and severe core instability during conventional core stabilization tests, we recently developed the dynamic neuromuscular stabilization-based heel sliding (DNS-HS) test. The purpose of this study was to establish the criterion validity and test-retest reliability of the novel DNS-HS test. Twenty young adults with core instability completed both the bilateral straight leg lowering test (BSLLT) and DNS-HS test for the criterion validity study and repeated the DNS-HS test for the test-retest reliability study. Criterion validity was determined by comparing hip joint angle data that were obtained from BSLLT and DNS-HS measures. The test-retest reliability was determined by comparing hip joint angle data. Criterion validity was (ICC2,3) = 0.700 (p< 0.05), suggesting a good relationship between the two core stability measures. Test-retest reliability was (ICC3,3) = 0.953 (p< 0.05), indicating excellent consistency between the repeated DNS-HS measurements. Criterion validity data demonstrated a good relationship between the gold standard BSLLT and DNS-HS core stability measures. Test-retest reliability data suggests that DNS-HS core stability was a reliable test for core stability. Clinically, the DNS-HS test is useful to objectively quantify core instability and allow early detection and evaluation.

  11. A simple, sensitive and rapid isocratic reversed-phase high-performance liquid chromatography method for determination and stability study of curcumin in pharmaceutical samples

    PubMed Central

    Amanolahi, Farjad; Mohammadi, Ali; Kazemi Oskuee, Reza; Nassirli, Hooriyeh; Malaekeh-Nikouei, Bizhan

    2017-01-01

    Objective: This study was designed to develop and validate a new reversed-phase high-performance liquid chromatography (RP-HPLC) method based on Q2 (R1) International Conference on Harmonization (ICH) guideline for determination of curcumin in pharmaceutical samples. Materials and Methods: The HPLC instrument method was optimized with isocratic elution with acetonitrile: ammonium acetate (45:55, v/v, pH 3.5), C18 column (150 mm×4.6 mm×5 µm particle size) and a flow rate of 1 ml/min in ambient condition and total retention time of 17 min. The volume of injection was set at 20 µl and detection was recorded at 425 nm. The robustness of the method was examined by changing the mobile phase composition, mobile phase pH, and flow rate. Results: The method was validated with respect to precision, accuracy and linearity in a concentration range of 2-100 µg/ml. The limit of detection (LOD) and limit of quantification (LOQ) were 0.25 and 0.5 µg/ml, respectively. The percentage of recovery was 98.9 to 100.5 with relative standard deviation (RSD) < 0.638%. Conclusion: The method was found to be simple, sensitive and rapid for determination of curcumin in pharmaceutical samples and had enough sensitivity to detect degradation product of curcumin produced under photolysis and hydrolysis stress condition. PMID:29062806

  12. Simultaneous determination of phenolic acids and flavonoids in rice using solid-phase extraction and RP-HPLC with photodiode array detection.

    PubMed

    Irakli, Maria N; Samanidou, Victoria F; Biliaderis, Costas G; Papadoyannis, Ioannis N

    2012-07-01

    An analytical method based on an optimized solid-phase extraction procedure and followed by high-performance liquid chromatography (HPLC) separation with diode array detection was developed and validated for the simultaneous determination of phenolic acids (gallic, protocatechuic, 4-hydroxy-benzoic, vanillic, caffeic, syringic, p-coumaric, ferulic, sinapic, and cinnamic acids), flavanols (catechin and epicatechin), flavonols (myricetin, quercetin, kaempferol, quercetin-3-O-glucoside, hyperoside, and rutin), flavones (luteolin and apigenin) and flavanones (naringenin and hesperidin) in rice flour (Oryza sativa L.). Chromatographic separation was carried out on a PerfectSil Target ODS-3 (250 mm × 4.6 mm, 3 μm) column at temperature 25°C using a mobile phase, consisting of 0.5% (v/v) acetic acid in water, methanol, and acetonitrile at a flow rate 1 mL min(-1) , under gradient elution conditions. Application of optimum extraction conditions, elaborated on both Lichrolut C(18) and Oasis HLB cartridges, have led to extraction of phenolic acids and flavonoids from rice flour with mean recoveries 84.3-113.0%. The developed method was validated in terms of linearity, accuracy, precision, stability, and sensitivity. Repeatability (n = 5) and inter-day precision (n = 4) revealed relative standard deviation (RSD) <13%. The optimized method was successfully applied to the analysis of phenolic acids and flavonoids in pigmented (red and black rice) and non-pigmented rice (brown rice) samples. © 2012 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  13. Study on the interaction of plasma protein binding rate between edaravone and taurine in human plasma based on HPLC analysis coupled with ultrafiltration technique.

    PubMed

    Tang, Dao-quan; Li, Yin-jie; Li, Zheng; Bian, Ting-ting; Chen, Kai; Zheng, Xiao-xiao; Yu, Yan-yan; Jiang, Shui-shi

    2015-08-01

    In this work, two high-performance liquid chromatography (HPLC) assays were developed and validated for the independent determination of edaravone and taurine using 3-methyl-1-p-tolyl-5-pyrazolone and L-glutamine as internal standards. In in vitro experiments, human plasma was separately spiked with a mixture of edaravone and taurine, edaravone or taurine alone. Plasma was precipitated with acetonitrile containing 0.1% formic acid. Ultrafiltration was employed to obtain the unbound ingredients of the two drugs. The factors that might influence the ultrafiltration effiency were elaborately optimized. Plasma supernatant and ultrafiltrate containing taurine were derivated with o-phthalaldehyde and ethanethiol in the presence of 40 mmol/L sodium borate buffer (pH 10.2) at room temperature within 1 min. Chromatographic separations were achieved on an InertSustain C18 column (250 × 4.6 mm, 5 µm). Isocratic 50 mmol/L ammonium acetate-acetonitrile and gradient 50 mmol/L sodium acetate (pH 5.3)-methanol were respectively selected as the mobile phase for the determination of edaravone and taurine. All of the validation data including linearity, extraction recovery, precision, accuracy and stability conformed to the requirements. Results showed that there were no significant alterations in the plasma protein binding rate of taurine and edaravone, implying that the proposed combination therapy was pharmacologically feasible. Copyright © 2014 John Wiley & Sons, Ltd.

  14. A validated solid-phase extraction HPLC method for the simultaneous determination of the citrus flavanone aglycones hesperetin and naringenin in urine.

    PubMed

    Kanaze, Feras Imad; Kokkalou, Eugene; Georgarakis, Manolis; Niopas, Ioannis

    2004-09-21

    A simple, specific, precise, accurate, and robust HPLC assay for the simultaneous analysis of hesperetin and naringenin in human urine was developed and validated. Urine samples were incubated with beta-glucuronidase/sulphatase and the analytes were isolated by solid-phase extraction using C18 cartridges and separated on a C8 reversed phase column using a mixture of methanol/water/acetic acid (40:58:2, v/v/v) at 45 degrees C. The method was found to be linear in the 50-1200 ng/ml concentration range for both hesperetin and naringenin (r > 0.999). The accuracy of the method was greater than 94.8%, while the intra- and inter-day precision for hesperetin was better than 4.9 and 8.2%, respectively and for naringenin was better than 5.3 and 7.8%, respectively. Recovery for hesperetin, naringenin and internal standard 7-ethoxycoumarin was greater than 70.9%. The method has been applied for the determination of hesperetin and naringenin in urine samples obtained from a male volunteer following a single 300 mg oral dose of each of the corresponding flavanone glycosides hesperidin and naringin. The intra- and inter-day reproducibility through enzyme hydrolysis was less than 3.9% for both total (free + conjugated) hesperetin and naringenin. Stability studies showed urine quality control samples to be stable for both hesperetin and naringenin through three freeze-thaw cycles and at room temperature for 24 h (error < or = 3.6%).

  15. Simultaneous Quantitative Determination of 12 Active Components in Yuanhu Zhitong Prescription by RP-HPLC Coupled with Photodiode Array Detection

    PubMed Central

    Zhang, Xiaokai; Zhang, Song; Yang, Qian; Cao, Wei; Xie, Yanhua; Qiu, Pengcheng; Wang, Siwang

    2015-01-01

    Background: Yuanhu Zhitong prescription (YZP) is a famous traditional Chinese medicine formula, which is officially recorded in Chinese Pharmacopoeia for the treatment of stomach pain, hypochondriac pain, headache and dysmenorrhea caused by qi-stagnancy and blood stasis. It is the first report for the simultaneous determination of 12 active components in YZP. Objective: A newly, simple, accurate and reliable method for the separation and determination of 12 active components (protopine, α-allocryptopine, coptisine, xanthotol, palmatine, dehydrocorydaline, glaucine, tetrahydropalmatine, tetrahydroberberine, imperatorin, corydaline, isoimperatorin) in YZP was developed and validated using HPLC-PAD. Materials and Methods: The analytes were performed on a Phenomenex Luna-C18 (2) column (250×4.6 mm, 5.0 μm) with a gradient elution program using a mixture of acetonitrile and 0.1% phosphoric acid water solution (adjusted with triethylamine to pH 5.6) as mobile phase. Analytes were performed at 30°C with a flow rate of 1.0 mL/min. Results: The validated method was applied to analyze four major dosage forms of YZP coming from different manufacturers with good linearity (r2, 0.9981~0.9999), precision (RSD, 0.24~2.89%), repeatability (RSD, 0.15~3.34%), stability (RSD, 0.14~3.35%), recovery (91.13~110.81%) of the 12 components. Conclusion: The proposed method enables the separation and determination of 12 active components in a single run for the quality control of YZP. PMID:25709212

  16. Development and Validation of Stability-Indicating Derivative Spectrophotometric Methods for Determination of Dronedarone Hydrochloride

    NASA Astrophysics Data System (ADS)

    Chadha, R.; Bali, A.

    2016-05-01

    Rapid, sensitive, cost effective and reproducible stability-indicating derivative spectrophotometric methods have been developed for the estimation of dronedarone HCl employing peak-zero (P-0) and peak-peak (P-P) techniques, and their stability-indicating potential assessed in forced degraded solutions of the drug. The methods were validated with respect to linearity, accuracy, precision and robustness. Excellent linearity was observed in concentrations 2-40 μg/ml ( r 2 = 0.9986). LOD and LOQ values for the proposed methods ranged from 0.42-0.46 μg/ml and 1.21-1.27 μg/ml, respectively, and excellent recovery of the drug was obtained in the tablet samples (99.70 ± 0.84%).

  17. Stability Test and Quantitative and Qualitative Analyses of the Amino Acids in Pharmacopuncture Extracted from Scolopendra subspinipes mutilans

    PubMed Central

    Cho, GyeYoon; Han, KyuChul; Yoon, JinYoung

    2015-01-01

    Objectives: Scolopendra subspinipes mutilans (S. subspinipes mutilans) is known as a traditional medicine and includes various amino acids, peptides and proteins. The amino acids in the pharmacopuncture extracted from S. subspinipes mutilans by using derivatization methods were analyzed quantitatively and qualitatively by using high performance liquid chromatography (HPLC) over a 12 month period to confirm its stability. Methods: Amino acids of pharmacopuncture extracted from S. subspinipes mutilans were derived by using O-phthaldialdehyde (OPA) & 9-fluorenyl methoxy carbonyl chloride (FMOC) reagent and were analyzed using HPLC. The amino acids were detected by using a diode array detector (DAD) and a fluorescence detector (FLD) to compare a mixed amino acid standard (STD) to the pharmacopuncture from centipedes. The stability tests on the pharmacopuncture from centipedes were done using HPLC for three conditions: a room temperature test chamber, an acceleration test chamber, and a cold test chamber. Results: The pharmacopuncture from centipedes was prepared by using the method of the Korean Pharmacopuncture Institute (KPI) and through quantitative analyses was shown to contain 9 amino acids of the 16 amino acids in the mixed amino acid STD. The amounts of the amino acids in the pharmacopuncture from centipedes were 34.37 ppm of aspartate, 123.72 ppm of arginine, 170.63 ppm of alanine, 59.55 ppm of leucine and 57 ppm of lysine. The relative standard deviation (RSD %) results for the pharmacopuncture from centipedes had a maximum value of 14.95% and minimum value of 1.795% on the room temperature test chamber, the acceleration test chamber and the cold test chamber stability tests. Conclusion: Stability tests on and quantitative and qualitative analyses of the amino acids in the pharmacopuncture extracted from centipedes by using derivatization methods were performed by using HPLC. Through research, we hope to determine the relationship between time and the concentrations of the amino acids in the pharmacopuncture extracted from centipedes. PMID:25830058

  18. Stability Test and Quantitative and Qualitative Analyses of the Amino Acids in Pharmacopuncture Extracted from Scolopendra subspinipes mutilans.

    PubMed

    Cho, GyeYoon; Han, KyuChul; Yoon, JinYoung

    2015-03-01

    Scolopendra subspinipes mutilans (S. subspinipes mutilans) is known as a traditional medicine and includes various amino acids, peptides and proteins. The amino acids in the pharmacopuncture extracted from S. subspinipes mutilans by using derivatization methods were analyzed quantitatively and qualitatively by using high performance liquid chromatography (HPLC) over a 12 month period to confirm its stability. Amino acids of pharmacopuncture extracted from S. subspinipes mutilans were derived by using O-phthaldialdehyde (OPA) & 9-fluorenyl methoxy carbonyl chloride (FMOC) reagent and were analyzed using HPLC. The amino acids were detected by using a diode array detector (DAD) and a fluorescence detector (FLD) to compare a mixed amino acid standard (STD) to the pharmacopuncture from centipedes. The stability tests on the pharmacopuncture from centipedes were done using HPLC for three conditions: a room temperature test chamber, an acceleration test chamber, and a cold test chamber. The pharmacopuncture from centipedes was prepared by using the method of the Korean Pharmacopuncture Institute (KPI) and through quantitative analyses was shown to contain 9 amino acids of the 16 amino acids in the mixed amino acid STD. The amounts of the amino acids in the pharmacopuncture from centipedes were 34.37 ppm of aspartate, 123.72 ppm of arginine, 170.63 ppm of alanine, 59.55 ppm of leucine and 57 ppm of lysine. The relative standard deviation (RSD %) results for the pharmacopuncture from centipedes had a maximum value of 14.95% and minimum value of 1.795% on the room temperature test chamber, the acceleration test chamber and the cold test chamber stability tests. Stability tests on and quantitative and qualitative analyses of the amino acids in the pharmacopuncture extracted from centipedes by using derivatization methods were performed by using HPLC. Through research, we hope to determine the relationship between time and the concentrations of the amino acids in the pharmacopuncture extracted from centipedes.

  19. [Study on stability of curcumine, demethoxycurcumin and bisdemethoxycurcumin].

    PubMed

    Han, Gang; Cui, Jing-jing; Bi, Rui; Zhao, Lin-lin; Zhang, Wei-guo

    2008-11-01

    To investigate the stability of curcumin, demethoxycurcumin and bisdemethoxycurcumin in different buffer solution. To determine concentration of curcumin by HPLC when added curcumin, demethoxycurcumin and bisdemethoxycurcumin into the buffer solution the equation of degradation was established. The sequence of stability are bisdemethoxycurcumin > or = demethoxycurcumin > or =curcumin at the same condition. The demethoxycurcumin can stabilize curcumin more strong than the others. The demethoxycurcumin is a nature stabilizing agent for curcumin.

  20. HPLC-Based Activity Profiling for GABAA Receptor Modulators in Extracts: Validation of an Approach Utilizing a Larval Zebrafish Locomotor Assay.

    PubMed

    Moradi-Afrapoli, Fahimeh; Ebrahimi, Samad Nejad; Smiesko, Martin; Hamburger, Matthias

    2017-05-26

    Gamma-aminobutyric acid type A (GABA A ) receptors are major inhibitory neurotransmitter receptors in the central nervous system and a target for numerous clinically important drugs used to treat anxiety, insomnia, and epilepsy. A series of allosteric GABA A receptor agonists was identified previously with the aid of HPLC-based activity profiling, whereby activity was tracked with an electrophysiological assay in Xenopus laevis oocytes. To accelerate the discovery process, an approach has been established for HPLC-based profiling using a larval zebrafish (Danio rerio) seizure model induced by pentylenetetrazol (PTZ), a pro-convulsant GABA A receptor antagonist. The assay was validated with the aid of representative GABAergic plant compounds and extracts. Various parameters that are relevant for the quality of results obtained, including PTZ concentration, the number of larvae, the incubation time, and the data analysis protocol, were optimized. The assay was then translated into an HPLC profiling protocol, and active compounds were tracked in extracts of Valeriana officinalis and Magnolia officinalis. For selected compounds the effects in the zebrafish larvae model were compared with data from in silico blood-brain barrier (BBB) permeability predictions, to validate the use for discovery of BBB-permeable natural products.

  1. Quality Analysis of Chlorogenic Acid and Hyperoside in Crataegi fructus

    PubMed Central

    Weon, Jin Bae; Jung, Youn Sik; Ma, Choong Je

    2016-01-01

    Background: Crataegi fructus is a herbal medicine for strong stomach, sterilization, and alcohol detoxification. Chlorogenic acid and hyperoside are the major compounds in Crataegi fructus. Objective: In this study, we established novel high-performance liquid chromatography (HPLC)-diode array detection analysis method of chlorogenic acid and hyperoside for quality control of Crataegi fructus. Materials and Methods: HPLC analysis was achieved on a reverse-phase C18 column (5 μm, 4.6 mm × 250 mm) using water and acetonitrile as mobile phase with gradient system. The method was validated for linearity, precision, and accuracy. About 31 batches of Crataegi fructus samples collected from Korea and China were analyzed by using HPLC fingerprint of developed HPLC method. Then, the contents of chlorogenic acid and hyperoside were compared for quality evaluation of Crataegi fructus. Results: The results have shown that the average contents (w/w %) of chlorogenic acid and hyperoside in Crataegi fructus collected from Korea were 0.0438% and 0.0416%, respectively, and the average contents (w/w %) of 0.0399% and 0.0325%, respectively. Conclusion: In conclusion, established HPLC analysis method was stable and could provide efficient quality evaluation for monitoring of commercial Crataegi fructus. SUMMARY Quantitative analysis method of chlorogenic acid and hyperoside in Crataegi fructus is developed by high.performance liquid chromatography.(HPLC).diode array detectionEstablished HPLC analysis method is validated with linearity, precision, and accuracyThe developed method was successfully applied for quantitative analysis of Crataegi fructus sample collected from Korea and China. Abbreviations used: HPLC: High-performance liquid chromatography, GC: Gas chromatography, MS: Mass spectrometer, LOD: Limits of detection, LOQ: Limits of quantification, RSD: Relative standard deviation, RRT: Relative retention time, RPA: Relation peak area. PMID:27076744

  2. Development and validation of high-performance liquid chromatography and high-performance thin-layer chromatography methods for the quantification of khellin in Ammi visnaga seed

    PubMed Central

    Kamal, Abid; Khan, Washim; Ahmad, Sayeed; Ahmad, F. J.; Saleem, Kishwar

    2015-01-01

    Objective: The present study was used to design simple, accurate and sensitive reversed phase-high-performance liquid chromatography RP-HPLC and high-performance thin-layer chromatography (HPTLC) methods for the development of quantification of khellin present in the seeds of Ammi visnaga. Materials and Methods: RP-HPLC analysis was performed on a C18 column with methanol: Water (75: 25, v/v) as a mobile phase. The HPTLC method involved densitometric evaluation of khellin after resolving it on silica gel plate using ethyl acetate: Toluene: Formic acid (5.5:4.0:0.5, v/v/v) as a mobile phase. Results: The developed HPLC and HPTLC methods were validated for precision (interday, intraday and intersystem), robustness and accuracy, limit of detection and limit of quantification. The relationship between the concentration of standard solutions and the peak response was linear in both HPLC and HPTLC methods with the concentration range of 10–80 μg/mL in HPLC and 25–1,000 ng/spot in HPTLC for khellin. The % relative standard deviation values for method precision was found to be 0.63–1.97%, 0.62–2.05% in HPLC and HPTLC for khellin respectively. Accuracy of the method was checked by recovery studies conducted at three different concentration levels and the average percentage recovery was found to be 100.53% in HPLC and 100.08% in HPTLC for khellin. Conclusions: The developed HPLC and HPTLC methods for the quantification of khellin were found simple, precise, specific, sensitive and accurate which can be used for routine analysis and quality control of A. visnaga and several formulations containing it as an ingredient. PMID:26681890

  3. A direct HPLC method for the resolution and quantitation of the R-(-)- and S-(+)-enantiomers of vigabatrin (gamma-vinyl-GABA) in pharmaceutical dosage forms using teicoplanin aglycone chiral stationary phase.

    PubMed

    Al-Majed, Abdulrahman A

    2009-08-15

    A direct chiral high-performance liquid chromatography (HPLC) method was developed and validated for the resolution and quantification of antiepileptic drug enantiomers, R-(-)- and S-(+)-vigabatrin (gamma-vinyl-gamma-aminobutyric acid) in pharmaceutical products. The separation was optimized on a macrocyclic glycopeptide antibiotic chiral stationary phase (CSP) based on teicoplanin aglycone, chirobiotic (TAG), using a mobile phase system containing ethanol-water (80:20, v/v), at a flow rate of 0.4ml/min and UV detection set at 210nm. The stability of vigabatrin enantiomers under different degrees of temperature was also studied. The enantiomers of vigabatrin were separated from each other. The calibration curves were linear over a range of 100-1600microg/ml (r=0.999) for both enantiomers. The overall recoveries of R-(-)- and S-(+)-vigabatrin enantiomers from pharmaceutical products were in the range of 98.3-99.8% with %RSD ranged from 0.48 to 0.52%. The limit of quantification (LOQ) and limit of detection (LOD) for each enantiomer were 100 and 25microg/ml, respectively. No interferences were found from commonly co-formulated excipients.

  4. Gradient RP-HPLC method for the determination of potential impurities in atazanavir sulfate.

    PubMed

    Chitturi, Sreenivasa Rao; Somannavar, Yallappa Somappa; Peruri, Badarinadh Gupta; Nallapati, Sreenivas; Sharma, Hemant Kumar; Budidet, Shankar Reddy; Handa, Vijay Kumar; Vurimindi, Hima Bindu

    2011-04-28

    This paper proposes a simple and selective RP-HPLC method for the determination of process impurities and degradation products (degradants) of atazanavir sulfate (ATV) drug substance. Chromatographic separation was achieved on Ascentis(®) Express C8, (150mm×4.6mm, 2.7μm) column thermostated at 30°C under gradient elution by a binary mixture of potassium dihydrogen phosphate (pH 3.5, 0.02M) and ACN at a flow rate of 1.0ml/min. A photodiode array (PDA) detector set at 250nm was used for detection. Stress testing (forced degradation) of ATV was carried out under acidic, alkaline, oxidative, photolytic, thermal and humidity conditions. In presence of alkali, ATV transformed into cyclized products and the order of degradation reaction is determined by the method of initial rates. The unknown process impurities and alkaline degradants are isolated by preparative LC and characterized by ESI-MS/MS, (1)H NMR, and FT-IR spectral data. The developed method is validated with respect to sensitivity (lod and loq), linearity, precision, accuracy and robustness and can be implemented for routine quality control analysis and stability testing of ATV. Copyright © 2011 Elsevier B.V. All rights reserved.

  5. Fingerprint chromatogram analysis of extracts from the leaves of Tripterygium wilfordii Hook. F. by high performance liquid chromatography.

    PubMed

    Li, Ke; Wang, Shudong

    2005-05-01

    A simple and reliable high performance liquid chromatographic (HPLC) method has been developed and validated for the study of fingerprint chromatograms of extracts from the leaves of Tripterygium wilfordii Hook. F. (TWHF) and for controlling the quality of the herb. HPLC separation of the extracts was performed on a Lichrospher RP-18 column and detected by ultraviolet absorbance at 210 nm. The column temperature was maintained at 35 degrees C. A mobile phase composed of acetonitrile:H2O in the ratio of 39:61 (v/v) was found to be most suitable for this separation at a flow rate of 0.8 mL/min with isocratic elution. Under the chromatographic conditions described, the peak profile of the 10 components collected within 35 min made up the fingerprint of the extracts from leaves of TWHF with universal features. The fingerprint chromatograms had a good stability, precision, and reproducibility. The similarity of the extracts from leaves of TWHF collected in summer and winter was studied with triptolide as a reference peak. The method is suitable for differentiation of extracts from the leaves of TWHF, and can be used as a quality control method for this herb.

  6. Roasting pumpkin seeds and changes in the composition and oxidative stability of cold-pressed oils.

    PubMed

    Raczyk, Marianna; Siger, Aleksander; Radziejewska-Kubzdela, Elżbieta; Ratusz, Katarzyna; Rudzińska, Magdalena

    2017-01-01

    Pumpkin seed oil is valuable oil for its distinctive taste and aroma, as well as supposed health- promoting properties. The aim of this study was to investigate how roasting pumpkin seeds influences the physicochemical properties of cold-pressed oils. The fatty acid composition, content of phytosterols, carotenoids and tocopherols, oxidative stability and colour were determined in oils after cold pressing and storage for 3 months using GC-FID, GCxGC-ToFMS, HPLC, Rancimat and spectrophotometric methods. The results of this study indicate that the seed-roasting and storage process have no effect on the fatty acid composition of pumpkin seed oils, but does affect phytosterols and tocopherols. The carotenoid content decreased after storage. The colour of the roasted oil was darker and changed significantly during storage. Pumpkin oil obtained from roasted seeds shows better physicochemical properties and oxidative stability than oil from unroasted seeds.

  7. Postmarketing in vitro/in vivo assessment of fixed dose combination products of first line antiretrovirals.

    PubMed

    Joshi, A; Esseku, F; Silva, L; Igwilo, C; Oqua, D; Kunle, B; Obodozie, O; Inyang, U; Adeyeye, Moji C

    2010-06-01

    The purpose of this study was to evaluate the postmarket pharmaceutical equivalence, stability and bioequivalence of generic and innovator fixed dose combination products of lamivudine (3TC) and zidovudine (AZT) 150/300 mg tablets available in Nigeria. An isocratic HPLC-UV method was developed and validated for the quantitative determination of 3TC and AZT in human plasma and pharmaceutical samples. The model independent f(2) similarity factor was used to compare the dissolution profiles of the two products stored at accelerated and long-term stability conditions for 6 months. The f(2) values for 3TC and AZT in both products were found to be greater than 51. Also, the tablets were stable according to the USP potency and drug dissolution criteria with more than 80% of drug dissolution in 30 min indicating the pharmaceutical equivalence of the two products. The 90% confidence interval for the ratios of generic/innovator pharmacokinetic parameters for 3TC/AZT were 73.5-112.6/63.4-95.8 (C(max)); 68.5-105.6/68.0-114.8 (AUC(0-t)); and 64.2-106.2/80.1-120.3 (AUC(0-infinity)) respectively. The pharmacokinetic parameters failed to fully demonstrate bioequivalence between the products. The results underscored the importance of assessing the quality of the combination drug products that would ensure the safety and efficacy of the generic drug products available in the market. (c) 2010 Wiley-Liss, Inc. and the American Pharmacists Association

  8. Long-Term Stability of Tramadol and Ketamine Solutions for Patient-Controlled Analgesia Delivery

    PubMed Central

    Gu, Junfeng; Qin, Wengang; Chen, Fuchao; Xia, Zhongyuan

    2015-01-01

    Background Subanesthetic doses of ketamine as an adjuvant to tramadol in patient-controlled analgesia (PCA) for postoperative pain have been shown to improve the quality of analgesia. However, there are no such commercially available drug mixtures, and the stability of the combination has rarely been assessed. Material/Methods Admixtures were assessed for periods of up to 14 days at 4°C and 25°C. Three different mixtures of tramadol and ketamine (tramadol 5.0 mg/mL + ketamine 0.5 mg/mL, tramadol 5.0 mg/mL + ketamine 1.0 mg/mL, and tramadol 5.0 mg/mL + ketamine 2.0 mg/mL) were prepared in polyolefin bags by combining these 2 drugs with 0.9% sodium chloride (normal saline [NS]). The chemical stability of the admixtures was evaluated by a validated high-performance liquid chromatography (HPLC) method and by measurement of pH values. Solution appearance and color were assessed by observing the samples against black and white backgrounds. Solutions were considered stable if they maintained 90% of the initial concentration of each drug. Results The percentages of initial concentration of tramadol and ketamine in the various solutions remained above 98% when stored at 4°C or 25°C over the testing period. No changes in color or turbidity were observed in any of the prepared solutions. Throughout this period, pH values remained stable. Conclusions The results indicate that the drug mixtures of tramadol with ketamine in NS for PCA delivery systems were stable for 14 days when stored in polyolefin bags at 4°C or 25°C. PMID:26306476

  9. Different Spectrophotometric Methods for Simultaneous Determination of Trelagliptin and Its Acid Degradation Product

    PubMed Central

    Hassan, Mostafa A.; Zaghary, Wafaa A.

    2018-01-01

    New spectrophotometric and chemometric methods were carried out for the simultaneous assay of trelagliptin (TRG) and its acid degradation product (TAD) and applied successfully as a stability indicating assay to recently approved Zafatek® tablets. TAD was monitored using TLC to ensure complete degradation. Furthermore, HPLC was used to confirm dealing with one major acid degradation product. The proposed methods were developed by manipulating zero-order, first-derivative, and ratio spectra of TRG and TAD using simultaneous equation, first-derivative, and mean-centering methods, respectively. Using Spectra Manager II and Minitab v.14 software, the absorbance at 274 nm–260.4 nm, amplitudes at 260.4 nm–274.0 nm, and mean-centered values at 287.6 nm–257.2 nm were measured against methanol as a blank for TRG and TAD, respectively. Linearity and the other validation parameters were acceptable at concentration ranges of 5–50 μg/mL and 2.5–25 μg/mL for TRG and TAD, respectively. Using one-way analysis of variance (ANOVA), the optimized methods were compared and proved to be accurate for the simultaneous assay of TRG and TAD. PMID:29629213

  10. Different Spectrophotometric Methods for Simultaneous Determination of Trelagliptin and Its Acid Degradation Product.

    PubMed

    Mowaka, Shereen; Ayoub, Bassam M; Hassan, Mostafa A; Zaghary, Wafaa A

    2018-01-01

    New spectrophotometric and chemometric methods were carried out for the simultaneous assay of trelagliptin (TRG) and its acid degradation product (TAD) and applied successfully as a stability indicating assay to recently approved Zafatek® tablets. TAD was monitored using TLC to ensure complete degradation. Furthermore, HPLC was used to confirm dealing with one major acid degradation product. The proposed methods were developed by manipulating zero-order, first-derivative, and ratio spectra of TRG and TAD using simultaneous equation, first-derivative, and mean-centering methods, respectively. Using Spectra Manager II and Minitab v.14 software, the absorbance at 274 nm-260.4 nm, amplitudes at 260.4 nm-274.0 nm, and mean-centered values at 287.6 nm-257.2 nm were measured against methanol as a blank for TRG and TAD, respectively. Linearity and the other validation parameters were acceptable at concentration ranges of 5-50  μ g/mL and 2.5-25  μ g/mL for TRG and TAD, respectively. Using one-way analysis of variance (ANOVA), the optimized methods were compared and proved to be accurate for the simultaneous assay of TRG and TAD.

  11. Ratio manipulating spectrophotometry versus chemometry as stability indicating methods for cefquinome sulfate determination.

    PubMed

    Yehia, Ali M; Arafa, Reham M; Abbas, Samah S; Amer, Sawsan M

    2016-01-15

    Spectral resolution of cefquinome sulfate (CFQ) in the presence of its degradation products was studied. Three selective, accurate and rapid spectrophotometric methods were performed for the determination of CFQ in the presence of either its hydrolytic, oxidative or photo-degradation products. The proposed ratio difference, derivative ratio and mean centering are ratio manipulating spectrophotometric methods that were satisfactorily applied for selective determination of CFQ within linear range of 5.0-40.0 μg mL(-1). Concentration Residuals Augmented Classical Least Squares was applied and evaluated for the determination of the cited drug in the presence of its all degradation products. Traditional Partial Least Squares regression was also applied and benchmarked against the proposed advanced multivariate calibration. Experimentally designed 25 synthetic mixtures of three factors at five levels were used to calibrate and validate the multivariate models. Advanced chemometrics succeeded in quantitative and qualitative analyses of CFQ along with its hydrolytic, oxidative and photo-degradation products. The proposed methods were applied successfully for different pharmaceutical formulations analyses. These developed methods were simple and cost-effective compared with the manufacturer's RP-HPLC method. Copyright © 2015 Elsevier B.V. All rights reserved.

  12. Modified HPLC-ESI-MS Method for Glycated Hemoglobin Quantification Based on the IFCC Reference Measurement Procedure and Its Application for Quantitative Analyses in Clinical Laboratories of China.

    PubMed

    Song, Zhixin; Xie, Baoyuan; Ma, Huaian; Zhang, Rui; Li, Pengfei; Liu, Lihong; Yue, Yuhong; Zhang, Jianping; Tong, Qing; Wang, Qingtao

    2016-09-01

    The level of glycated hemoglobin (HbA1c ) has been recognized as an important indicator of long-term glycemic control. However, the HbA1c measurement is not currently included as a diagnostic determinant in China. Current study aims to assess a candidate modified International Federation of Clinical Chemistry reference method for the forthcoming standardization of HbA1c measurements in China. The HbA1c concentration was measured using a modified high-performance liquid chromatography-electrospray ionization-mass spectrometry (HPLC-ESI-MS) method. The modified method replaces the propylcyanide column with a C18 reversed-phase column, which has a lower cost and is more commonly used in China, and uses 0.1% (26.5 mmol/l) formic acid instead of trifluoroacetic acid. Moreover, in order to minimize matrix interference and reduce the running time, a solid-phase extraction was employed. The discrepancies between HbA1c measurements using conventional methods and the HPLC-ESI-MS method were clarified in clinical samples from healthy people and diabetic patients. Corresponding samples were distributed to 89 hospitals in Beijing for external quality assessment. The linearity, reliability, and accuracy of the modified HPLC-ESI-MS method with a shortened running time of 6 min were successfully validated. Out of 89 hospitals evaluated, the relative biases of HbA1c concentrations were < 8% for 74 hospitals and < 5% for 60 hospitals. Compared with other conventional methods, HbA1c concentrations determined by HPLC methods were similar to the values obtained from the current HPLC-ESI-MS method. The HPLC-ESI-MS method represents an improvement over existing methods and provides a simple, stable, and rapid HbA1c measurement with strong signal intensities and reduced ion suppression. © 2015 Wiley Periodicals, Inc.

  13. Development and validation of RP HPLC method to determine nandrolone phenylpropionate in different pharmaceutical formulations.

    PubMed

    Mukherjee, Jayanti; Das, Ayan; Chakrabarty, Uday Sankar; Sahoo, Bijay Kumar; Dey, Goutam; Choudhury, Hira; Pal, Tapan Kumar

    2011-01-01

    This study describes development and subsequent validation of a reversed phase high performance liquid chromatographic (RP-HPLC) method for the estimation of nandrolone phenylpropionate, an anabolic steroid, in bulk drug, in conventional parenteral dosage formulation and in prepared nanoparticle dosage form. The chromatographic system consisted of a Luna Phenomenex, CN (250 mm x 4.6 mm, 5 microm) column, an isocratic mobile phase comprising 10 mM phosphate buffer and acetonitrile (50:50, v/v) and UV detection at 240 nm. Nandrolone phenylpropionate was eluted about 6.3 min with no interfering peaks of excipients used for the preparation of dosage forms. The method was linear over the range from 0.050 to 25 microg/mL in raw drug (r2 = 0.9994). The intra-day and inter-day precision values were in the range of 0.219-0.609% and 0.441-0.875%, respectively. Limits of detection and quantitation were 0.010 microg/mL and 0.050 microg/mL, respectively. The results were validated according to International Conference on Harmonization (ICH) guidelines in parenteral and prepared nanoparticle formulation. The validated HPLC method is simple, sensitive, precise, accurate and reproducible.

  14. Chemical compositions, chromatographic fingerprints and antioxidant activities of Andrographis Herba.

    PubMed

    Zhao, Yang; Kao, Chun-Pin; Wu, Kun-Chang; Liao, Chi-Ren; Ho, Yu-Ling; Chang, Yuan-Shiun

    2014-11-10

    This paper describes the development of an HPLC-UV-MS method for quantitative determination of andrographolide and dehydroandrographolide in Andrographis Herba and establishment of its chromatographic fingerprint. The method was validated for linearity, limit of detection and quantification, inter- and intra-day precisions, repeatability, stability and recovery. All the validation results of quantitative determination and fingerprinting methods were satisfactory. The developed method was then applied to assay the contents of andrographolide and dehydroandrographolide and to acquire the fingerprints of all the collected Andrographis Herba samples. Furthermore, similarity analysis and principal component analysis were used to reveal the similarities and differences between the samples on the basis of the characteristic peaks. More importantly, the DPPH free radical-scavenging and ferric reducing capacities of the Andrographis Herba samples were assayed. By bivariate correlation analysis, we found that six compounds are positively correlated to DPPH free radical scavenging and ferric reducing capacities, and four compounds are negatively correlated to DPPH free radical scavenging and ferric reducing capacities.

  15. Determination of rifampicin in human plasma by high-performance liquid chromatography coupled with ultraviolet detection after automatized solid-liquid extraction.

    PubMed

    Louveau, B; Fernandez, C; Zahr, N; Sauvageon-Martre, H; Maslanka, P; Faure, P; Mourah, S; Goldwirt, L

    2016-12-01

    A precise and accurate high-performance liquid chromatography (HPLC) quantification method of rifampicin in human plasma was developed and validated using ultraviolet detection after an automatized solid-phase extraction. The method was validated with respect to selectivity, extraction recovery, linearity, intra- and inter-day precision, accuracy, lower limit of quantification and stability. Chromatographic separation was performed on a Chromolith RP 8 column using a mixture of 0.05 m acetate buffer pH 5.7-acetonitrile (35:65, v/v) as mobile phase. The compounds were detected at a wavelength of 335 nm with a lower limit of quantification of 0.05 mg/L in human plasma. Retention times for rifampicin and 6,7-dimethyl-2,3-di(2-pyridyl) quinoxaline used as internal standard were respectively 3.77 and 4.81 min. This robust and exact method was successfully applied in routine for therapeutic drug monitoring in patients treated with rifampicin. Copyright © 2016 John Wiley & Sons, Ltd.

  16. Quantitative Analysis and Comparison of Four Major Flavonol Glycosides in the Leaves of Toona sinensis (A. Juss.) Roemer (Chinese Toon) from Various Origins by High-Performance Liquid Chromatography-Diode Array Detector and Hierarchical Clustering Analysis

    PubMed Central

    Sun, Xiaoxiang; Zhang, Liting; Cao, Yaqi; Gu, Qinying; Yang, Huan; Tam, James P.

    2016-01-01

    Background: Toona sinensis (A. Juss.) Roemer is an endemic species of Toona genus native to Asian area. Its dried leaves are applied in the treatment of many diseases; however, few investigations have been reported for the quantitative analysis and comparison of major bioactive flavonol glycosides in the leaves harvested from various origins. Objective: To quantitatively analyze four major flavonol glycosides including rutinoside, quercetin-3-O-β-D-glucoside, quercetin-3-O-α-L-rhamnoside, and kaempferol-3-O-α-L-rhamnoside in the leaves from different production sites and classify them according to the content of these glycosides. Materials and Methods: A high-performance liquid chromatography-diode array detector (HPLC-DAD) method for their simultaneous determination was developed and validated for linearity, precision, accuracy, stability, and repeatability. Moreover, the method established was then employed to explore the difference in the content of these four glycosides in raw materials. Finally, a hierarchical clustering analysis was performed to classify 11 voucher specimens. Results: The separation was performed on a Waters XBridge Shield RP18 column (150 mm × 4.6 mm, 3.5 μm) kept at 35°C, and acetonitrile and H2O containing 0.30% trifluoroacetic acid as mobile phase was driven at 1.0 mL/min during the analysis. Ten microliters of solution were injected and 254 nm was selected to monitor the separation. A strong linear relationship between the peak area and concentration of four analytes was observed. And, the method was also validated to be repeatable, stable, precise, and accurate. Conclusion: An efficient and reliable HPLC-DAD method was established and applied in the assays for the samples from 11 origins successfully. Moreover, the content of those flavonol glycosides varied much among different batches, and the flavonoids could be considered as biomarkers to control the quality of Chinese Toon. SUMMARY Four major flavonol glycosides in the leaves of Toona sinensis were determined by HPLC-DAD and their contents were compared among various origins by HCA. Abbreviations used: HPLC-DAD: High-performance liquid chromatography-diode array detector, HCA: Hierarchical clustering analysis, MS: Mass spectrometry, RSD: Relative standard deviation. PMID:27279719

  17. Norelgestromin/ethinyl estradiol intravenous infusion formulation optimization, stability and compatibility testing: A case study to overcome polysorbate 80 interference in chromatographic analysis.

    PubMed

    Abdallah, Inas A; Hammell, Dana C; Hassan, Hazem E; Stinchcomb, Audra L

    2016-06-05

    Norelgestromin/ethinyl estradiol is a progestin/estrogen combination hormonal contraceptive indicated for the prevention of pregnancy in women. The very poor solubility and wettability of these drugs, along with their high potency (adsorption issues), give rise to difficulties in designing intravenous (IV) formulations to assess absolute bioavailability of products containing both drugs. The purpose of this study was to develop an IV formulation, evaluate its stability under different conditions and evaluate its compatibility with IV sets for potential use in absolute bioavailability studies in humans. Also, a selective high-performance liquid chromatography (HPLC) method for quantification of ethinyl estradiol and norelgestromin in polysorbate 80 matrix was developed and validated. Norelgestromin/ethinyl estradiol IV solution was prepared using sterile water for injection with 2.5% ethanol and 2.5% polysorbate 80 as a cosolvent/surfactant system to obtain a final drug solution of 25μg ethinyl estradiol and 252μg norelgestromin from a concentrated stock drug solution. The stabilities of the concentrated stock and IV solutions were assessed after storing them in the refrigerator (3.7±0.6°C) and at room temperature (19.5±0.5°C), respectively. Additional studies were conducted to examine the stability of the IV solution using an Alarias(®) low sorbing IV administration set with and without an inline filter. The solution was allowed to drip at 1mL/min over a 60min period. Samples were obtained at the beginning, middle and end of the 60min duration. The chemical stability was evaluated for up to 10 days. Norelgestromin and ethinyl estradiol concentration, purity, and degradant levels were determined using the HPLC method. The norelgestromin/ethinyl estradiol IV formulation met the chemical stability criteria when tested on day 1 through day 9 (216h). Norelgestromin concentrations assayed in stock and IV solutions were in the range of 90.0-98.5% and 90.9-98.8% after 9 days, respectively. As for ethinyl estradiol, the assayed concentrations were in the range of 91.8-100.9% and 92.7-100.8% for the stock and IV solutions, respectively. The administration set was found to be compatible with both drugs; the assayed concentrations were in the range of 99.2-100.3% for norelgestromin and 96.3-102.7% for ethinyl estradiol, but the inline filter showed some adsorption of ethinyl estradiol; where the assayed concentrations were in the range of 98.1-99.8% for norelgestromin and 95.9-97.4% for ethinyl estradiol. The present study provided evidence supporting the suitability of an intravenous formulation for norelgestromin/ethinyl estradiol using ethanol/polysorbate 80 as a cosolvent/surfactant system. Both IV and concentrated stock solutions when stored at room temperature and refrigeration, respectively, were found to be chemically stable up to 9 days. These results indicated that this formulation is chemically stable and can be used over the time period tested. This IV formulation can be used to evaluate the absolute bioavailability of products containing norelgestromin and ethinyl estradiol provided that microbial testing of the IV formulation is performed. Copyright © 2016. Published by Elsevier B.V.

  18. Diversity oriented high-throughput screening of 1,3,4-oxadiazole modified chlorophenylureas and halogenobenzamides by HPLC with peptidomimetic calixarene-bonded stationary phases.

    PubMed

    Bazylak, Grzegorz; Malak, Anna; Ali, Imran; Borowiak, Teresa; Dutkiewicz, Grzegorz

    2008-06-01

    Retention profiles in series of the neutral and highly hydrophobic 1,3,4-oxadiazoles containing chlorophenylurea and halogenobenzamide moiety and indicating analgesic activity were determined in the isocratic standard- and narrow-bore HPLC systems employing, respectively, various octadecylsilica and different calixarene bonded stationary phases. When acetonitrile - 2.65 mM phosphoric acid (55 : 45, %, v/v), pH* 3.25, mobile phase was applied retention of these compounds increased with decline of their overall hydrophobicity according to the general preference of more polar compounds by calixarene cavity in time of its non-specific host-guest supramolecular interactions with halogenated substances. The size of calixarene nanocavity and its upper-rim substitution did not change the observed retention order, resolution and selectivity of separation for oxadiazoles. Compared to the retention on the non-end-capped and the highly-end-capped octadecylsilica HPLC column a most improved separation of some regioisomers of halogenated 1,3,4-oxadiazoles were observed on both used calixarene-type HPLC supports. In addition, preliminary data on the self-assembled supramolecular crystal structure of exemplary 1,3,4-oxadiazolchlorophenylurea with cis-elongated conformation was reported and formation of the monovalent inclusion host-guest complexes between 1,3,4-oxadiazoles and each calixarene-type stationary phase was studied with molecular modelling MM+ and AM1 methods. The structural, isomeric and energetic factors leading to the hydrogen bond stabilized inclusion complexes between these species were considered and used for explanation of observed retention sequence and selectivity of 1,3,4-oxadiazoles separation in applied calixarene-based HPLC systems. All these data would be useful in future development of optimized procedures enabling encapsulation of 1,3,4-oxadiazolurea-type drugs with calixarenes.

  19. Improvement in Thermal Stability of Sucralose by γ-Cyclodextrin Metal-Organic Frameworks.

    PubMed

    Lv, Nana; Guo, Tao; Liu, Botao; Wang, Caifen; Singh, Vikaramjeet; Xu, Xiaonan; Li, Xue; Chen, Dawei; Gref, Ruxandra; Zhang, Jiwen

    2017-02-01

    To explain thermal stability enhancement of an organic compound, sucralose, with cyclodextrin based metal organic frameworks. Micron and nanometer sized basic CD-MOFs were successfully synthesized by a modified vapor diffusion method and further neutralized with glacial acetic acid. Sucralose was loaded into CD-MOFs by incubating CD-MOFs with sucralose ethanol solutions. Thermal stabilities of sucralose-loaded basic CD-MOFs and neutralized CD-MOFs were investigated using thermogravimetric analysis (TGA), differential scanning calorimetry (DSC) and high performance liquid chromatography with evaporative light-scattering detection (HPLC-ELSD). Scanning electron microscopy (SEM) and powder X-ray diffraction (PXRD) results showed that basic CD-MOFs were cubic crystals with smooth surface and uniform sizes. The basic CD-MOFs maintained their crystalline structure after neutralization. HPLC-ELSD analysis indicated that the CD-MOF crystal size had significant influence on sucralose loading (SL). The maximal SL of micron CD-MOFs (CD-MOF-Micro) was 17.5 ± 0.9% (w/w). In contrast, 27.9 ± 1.4% of sucralose could be loaded in nanometer-sized basic CD-MOFs (CD-MOF-Nano). Molecular docking modeling showed that sucralose molecules preferentially located inside the cavities of γ-CDs pairs in CD-MOFs. Raw sucralose decomposed fast at 90°C, with 86.2 ± 0.2% of the compound degraded within only 1 h. Remarkably, sucralose stability was dramatically improved after loading in neutralized CD-MOFs, with only 13.7 ± 0.7% degradation at 90°C within 24 h. CD-MOFs efficiently incorporated sucralose and maintained its integrity upon heating at elevated temperatures.

  20. Stability of penicillin G sodium diluted with 0.9% sodium chloride injection or 5% dextrose injection and stored in polyvinyl chloride bag containers and elastomeric pump containers.

    PubMed

    Hossain, Mirza Akram; Friciu, Mihaela; Aubin, Sebastien; Leclair, Grégoire

    2014-04-15

    The stability of penicillin G sodium solutions stored in polyvinyl chloride (PVC) bags or elastomeric pump containers was studied. Test samples were prepared by diluting powdered penicillin G sodium (10 million units/10-mL vial) to solutions of 2,500 or 50,000 units/mL with 0.9% sodium chloride injection or 5% dextrose injection. The preparations were transferred to 250-mL PVC bags and elastomeric pump containers. All samples were prepared in triplicate and stored at 5°C. Chemical stability was measured by a stability-indicating high-performance liquid chromatographic (HPLC) assay and by pH evaluation. Particulate matter was evaluated according to compendial standards using a light-obscuration particle count test. Preparations were visually examined throughout the study. After 21 days of storage, all test samples remained chemically stable, with an HPLC assay recovery value of more than 90% of the initial value. After 28 days, all samples prepared with either diluent and stored in PVC bags, as well as the samples diluted to 2,500 units/mL with sodium chloride injection and stored in elastomeric pump containers, did not meet the recovery acceptance limit. For all test samples, the mean pH consistently decreased during storage, from about 6.4 to about 5.5. Particle counts remained acceptable throughout the study, and no change in appearance was observed. Penicillin G for injection (2,500 and 50,000 units/mL) diluted in 0.9% sodium chloride injection or 5% dextrose injection and stored at 5°C in PVC containers or elastomeric pump containers was physically and chemically stable for a period of at least 21 days.

  1. Validated HPLC-Diode Array Detector Method for Simultaneous Evaluation of Six Quality Markers in Coffee.

    PubMed

    Gant, Anastasia; Leyva, Vanessa E; Gonzalez, Ana E; Maruenda, Helena

    2015-01-01

    Nicotinic acid, N-methylpyridinium ion, and trigonelline are well studied nutritional biomarkers present in coffee, and they are indicators of thermal decomposition during roasting. However, no method is yet available for their simultaneous determination. This paper describes a rapid and validated HPLC-diode array detector method for the simultaneous quantitation of caffeine, trigonelline, nicotinic acid, N-methylpyridinium ion, 5-caffeoylquinic acid, and 5-hydroxymethyl furfural that is applicable to three coffee matrixes: green, roasted, and instant. Baseline separation among all compounds was achieved in 30 min using a phenyl-hexyl RP column (250×4.6 mm, 5 μm particle size), 0.3% aqueous formic buffer (pH 2.4)-methanol mobile phase at a flow rate of 1 mL/min, and a column temperature at 30°C. The method showed good linear correlation (r2>0.9985), precision (less than 3.9%), sensitivity (LOD=0.023-0.237 μg/mL; LOQ=0.069-0.711 μg/mL), and recovery (84-102%) for all compounds. This simplified method is amenable for a more complete routine evaluation of coffee in industry.

  2. Solid lipid nanoparticles (SLN) and nanostructured lipid carriers (NLC) for application of ascorbyl palmitate.

    PubMed

    Uner, M; Wissing, S A; Yener, G; Müller, R H

    2005-08-01

    The aim of this study was to improve the chemical stability of ascorbyl palmitate (AP) in a colloidal lipid carrier for its topical use. For this purpose, AP-loaded solid lipid nanoparticles (SLN), nanostructured lipid carriers (NLC) and for comparison, a nanoemulsion (NE) were prepared employing the high pressure homogenization technique and stored at room temperature (RT), 4 degrees C and 40 degrees C. During 3 months, physical stability of these formulations compared to placebo formulations which were prepared by the same production method, was studied including recrystallization behaviour of the lipid with differential scanning calorimetry (DSC), particle size distribution and storage stability with photon correlation spectroscopy (PCS) and laser diffractometry (LD). After evaluating data indicating excellent physical stability, AP-loaded SLN, NLC and NE were incorporated into a hydrogel by the same production method as the next step. Degradation of AP by HPLC and physical stability in the same manner were investigated at the same storage temperatures during 3 months. As a result, AP was found most stable in both the NLC and SLN stored at 4 degrees C (p > 0.05) indicating the importance of storage temperature. Nondegraded AP content in NLC, SLN and NE was found to be 71.1% +/- 1.4, 67.6% +/- 2.9 and 55.2% +/- 0.3 after 3 months, respectively. Highest degradation was observed with NE at all the storage temperatures indicating even importance of the carrier structure.

  3. Validation of a simple HPLC-UV method for rifampicin determination in plasma: Application to the study of rifampicin arteriovenous concentration gradient.

    PubMed

    Goutal, Sébastien; Auvity, Sylvain; Legrand, Tiphaine; Hauquier, Fanny; Cisternino, Salvatore; Chapy, Hélène; Saba, Wadad; Tournier, Nicolas

    2016-05-10

    In clinical practice, rifampicin exposure is estimated from its concentration in venous blood samples. In this study, we hypothesized that differences in rifampicin concentration may exist between arterial and venous plasma. An HPLC-UV method for determining rifampicin concentration in plasma using rifapentine as an internal standard was validated. The method, which requires a simple protein precipitation procedure as sample preparation, was performed to compare venous and arterial plasma kinetics after a single therapeutic dose of rifampicin (8.6 mg/kg i.v, infused over 30 min) in baboons (n=3). The method was linear from 0.1 to 40 μg mL(-1) and all validation parameters fulfilled the international requirements. In baboons, rifampicin concentration in arterial plasma was higher than in venous plasma. Arterial Cmax was 2.1±0.2 fold higher than venous Cmax. The area under the curve (AUC) from 0 to 120 min was ∼80% higher in arterial plasma, indicating a significant arteriovenous concentration gradient in early rifampicin pharmacokinetics. Arterial and venous plasma concentrations obtained 6h after rifampicin injection were not different. An important arteriovenous equilibration delay for rifampicin pharmacokinetics is reported. Determination in venous plasma concentrations may considerably underestimate rifampicin exposure to organs during the distribution phase. Copyright © 2016 Elsevier B.V. All rights reserved.

  4. Comparison of high-performance liquid chromatography and supercritical fluid chromatography using evaporative light scattering detection for the determination of plasticizers in medical devices.

    PubMed

    Lecoeur, Marie; Decaudin, Bertrand; Guillotin, Yoann; Sautou, Valérie; Vaccher, Claude

    2015-10-23

    Recently, interest in supercritical fluid chromatography (SFC) has increased due to its high throughput and the development of new system improving chromatographic performances. However, most papers dealt with fundamental studies and chiral applications and only few works described validation process of SFC method. Likewise, evaporative light scattering detection (ELSD) has been widely employed in liquid chromatography but only a few recent works presented its quantitative performances hyphenated with SFC apparatus. The present paper discusses about the quantitative performances of SFC-ELSD compared to HPLC-ELSD, for the determination of plasticizers (ATBC, DEHA, DEHT and TOTM) in PVC tubing used as medical devices. After the development of HPLC-ELSD, both methods were evaluated based on the total error approach using accuracy profile. The results show that HPLC-ELSD was more precise than SFC-ELSD but lower limits of quantitation were obtained by SFC. Hence, HPLC was validated in the ± 10% acceptance limits whereas SFC lacks of accuracy to quantify plasticizers. Finally, both methods were used to determine the composition of plasticized-PVC medical devices. Results demonstrated that SFC and HPLC both hyphenated with ELSD provided similar results. Copyright © 2015 Elsevier B.V. All rights reserved.

  5. A simple and accurate HPLC method for fecal bile acid profile in healthy and cirrhotic subjects: validation by GC-MS and LC-MS[S

    PubMed Central

    Kakiyama, Genta; Muto, Akina; Takei, Hajime; Nittono, Hiroshi; Murai, Tsuyoshi; Kurosawa, Takao; Hofmann, Alan F.; Pandak, William M.; Bajaj, Jasmohan S.

    2014-01-01

    We have developed a simple and accurate HPLC method for measurement of fecal bile acids using phenacyl derivatives of unconjugated bile acids, and applied it to the measurement of fecal bile acids in cirrhotic patients. The HPLC method has the following steps: 1) lyophilization of the stool sample; 2) reconstitution in buffer and enzymatic deconjugation using cholylglycine hydrolase/sulfatase; 3) incubation with 0.1 N NaOH in 50% isopropanol at 60°C to hydrolyze esterified bile acids; 4) extraction of bile acids from particulate material using 0.1 N NaOH; 5) isolation of deconjugated bile acids by solid phase extraction; 6) formation of phenacyl esters by derivatization using phenacyl bromide; and 7) HPLC separation measuring eluted peaks at 254 nm. The method was validated by showing that results obtained by HPLC agreed with those obtained by LC-MS/MS and GC-MS. We then applied the method to measuring total fecal bile acid (concentration) and bile acid profile in samples from 38 patients with cirrhosis (17 early, 21 advanced) and 10 healthy subjects. Bile acid concentrations were significantly lower in patients with advanced cirrhosis, suggesting impaired bile acid synthesis. PMID:24627129

  6. Current HPLC Methods for Assay of Nano Drug Delivery Systems.

    PubMed

    Tekkeli, Serife Evrim Kepekci; Kiziltas, Mustafa Volkan

    2017-01-01

    In nano drug formulations the mechanism of release is a critical process to recognize controlled and targeted drug delivery systems. In order to gain high bioavailability and specificity from the drug to reach its therapeutic goal, the active substance must be loaded into the nanoparticles efficiently. Therefore, the amount in biological fluids or tissues and the remaining amount in nano carriers are very important parameters to understand the potential of the nano drug delivery systems. For this aim, suitable and validated quantitation methods are required to determine released drug concentrations from nano pharmaceutical formulations. HPLC (High Performance Liquid Chromatography) is one of the most common techniques used for determination of released drug content out of nano drug formulations, in different physical conditions, over different periods of time. Since there are many types of HPLC methods depending on detector and column types, it is a challenge for the researchers to choose a suitable method that is simple, fast and validated HPLC techniques for their nano drug delivery systems. This review's goal is to compare HPLC methods that are currently used in different nano drug delivery systems in order to provide detailed and useful information for researchers. Copyright© Bentham Science Publishers; For any queries, please email at epub@benthamscience.org.

  7. A simple method for HPLC retention time prediction: linear calibration using two reference substances.

    PubMed

    Sun, Lei; Jin, Hong-Yu; Tian, Run-Tao; Wang, Ming-Juan; Liu, Li-Na; Ye, Liu-Ping; Zuo, Tian-Tian; Ma, Shuang-Cheng

    2017-01-01

    Analysis of related substances in pharmaceutical chemicals and multi-components in traditional Chinese medicines needs bulk of reference substances to identify the chromatographic peaks accurately. But the reference substances are costly. Thus, the relative retention (RR) method has been widely adopted in pharmacopoeias and literatures for characterizing HPLC behaviors of those reference substances unavailable. The problem is it is difficult to reproduce the RR on different columns due to the error between measured retention time (t R ) and predicted t R in some cases. Therefore, it is useful to develop an alternative and simple method for prediction of t R accurately. In the present study, based on the thermodynamic theory of HPLC, a method named linear calibration using two reference substances (LCTRS) was proposed. The method includes three steps, procedure of two points prediction, procedure of validation by multiple points regression and sequential matching. The t R of compounds on a HPLC column can be calculated by standard retention time and linear relationship. The method was validated in two medicines on 30 columns. It was demonstrated that, LCTRS method is simple, but more accurate and more robust on different HPLC columns than RR method. Hence quality standards using LCTRS method are easy to reproduce in different laboratories with lower cost of reference substances.

  8. Solid-state stability studies of 13-cis-retinoic acid and all-trans-retinoic acid using microcalorimetry and HPLC analysis.

    PubMed

    Tan, X; Meltzer, N; Lindebaum, S

    1992-09-01

    The solid-state stabilities of 13-cis-retinoic acid and all-trans-retinoic acid in the presence and absence of oxygen were investigated. The samples were first evaluated using microcalorimetry. The rate laws of different samples under different conditions were deduced from the shapes of the heat flow curves, and the activation energies of the reactions were determined from Arrhenius plots. Under an air atmosphere, the decomposition of 13-cis-retinoic acid is an autocatalytic reaction, while all-trans-retinoic acid undergoes a zero-order process. The degradation of the two compounds at a selected elevated temperature was also determined utilizing HPLC analysis. This technique confirmed the decomposition kinetics. Hence, their half-lives and shelf lives at room temperature could be calculated. Under a nitrogen atmosphere, the microcalorimetric experiment showed a first-order phenomenon for both samples, but HPLC analysis showed no degradation, suggesting that the two samples, in the absence of oxygen, undergo only a physical change.

  9. Purification and stability characterization of a cell regulatory sialoglycopeptide inhibitor

    NASA Technical Reports Server (NTRS)

    Moos, P. J.; Fattaey, H. K.; Johnson, T. C.; Spooner, B. S. (Principal Investigator)

    1995-01-01

    Previous attempts to physically separate the cell cycle inhibitory and protease activities in preparations of a purified cell regulatory sialoglycopeptide (CeReS) inhibitor were largely unsuccessful. Gradient elution of the inhibitor preparation from a DEAE HPLC column separated the cell growth inhibitor from the protease, and the two activities have been shown to be distinct and non-overlapping. The additional purification increased the specific biological activity of the CeReS preparation by approximately two-fold. The major inhibitory fraction that eluted from the DEAE column was further analyzed by tricine-SDS-PAGE and microbore reverse phase HPLC and shown to be homogeneous in nature. Two other fractions separated by DEAE HPLC, also devoid of protease activity, were shown to be inhibitory to cell proliferation and most likely represented modified relatives of the CeReS inhibitor. The highly purified CeReS was chemically characterized for amino acid and carbohydrate composition and the role of the carbohydrate in cell proliferation inhibition, stability, and protease resistance was assessed.

  10. High-performance liquid chromatography method for the determination of hydrogen peroxide present or released in teeth bleaching kits and hair cosmetic products.

    PubMed

    Gimeno, Pascal; Bousquet, Claudine; Lassu, Nelly; Maggio, Annie-Françoise; Civade, Corinne; Brenier, Charlotte; Lempereur, Laurent

    2015-03-25

    This manuscript presents an HPLC/UV method for the determination of hydrogen peroxide present or released in teeth bleaching products and hair products. The method is based on an oxidation of triphenylphosphine into triphenylphosphine oxide by hydrogen peroxide. Triphenylphosphine oxide formed is quantified by HPLC/UV. Validation data were obtained using the ISO 12787 standard approach, particularly adapted when it is not possible to make reconstituted sample matrices. For comparative purpose, hydrogen peroxide was also determined using ceric sulfate titrimetry for both types of products. For hair products, a cross validation of both ceric titrimetric method and HPLC/UV method using the cosmetic 82/434/EEC directive (official iodometric titration method) was performed. Results obtained for 6 commercialized teeth whitening products and 5 hair products point out similar hydrogen peroxide contain using either the HPLC/UV method or ceric sulfate titrimetric method. For hair products, results were similar to the hydrogen peroxide content using the cosmetic 82/434/EEC directive method and for the HPLC/UV method, mean recoveries obtained on spiked samples, using the ISO 12787 standard, ranges from 100% to 110% with a RSD<3.0%. To assess the analytical method proposed, the HPLC method was used to control 35 teeth bleaching products during a market survey and highlight for 5 products, hydrogen peroxide contents higher than the regulated limit. Copyright © 2015 Elsevier B.V. All rights reserved.

  11. HPLC and HPLC/MS/MS Studies on Stress, Accelerated and Intermediate Degradation Tests of Antivirally Active Tricyclic Analog of Acyclovir.

    PubMed

    Lesniewska, Monika A; Dereziński, Paweł; Klupczyńska, Agnieszka; Kokot, Zenon J; Ostrowski, Tomasz; Zeidler, Joanna; Muszalska, Izabela

    2015-01-01

    The degradation behavior of a tricyclic analog of acyclovir [6-(4-MeOPh)-TACV] was determined in accordance with International Conference on Harmonization guidelines for good clinical practice under different stress conditions (neutral hydrolysis, strong acid/base degradation, oxidative decomposition, photodegradation, and thermal degradation). Accelerated [40±2°C/75%±5% relative humidity (RH)] and intermediate (30±2°C/65%±5% RH) stability tests were also performed. For observation of the degradation of the tested compound the RP-HPLC was used, whereas for the analysis of its degradation products HPLC/MS/MS was used. Degradation of the tested substance allowed its classification as unstable in neutral environment, acidic/alkaline medium, and in the presence of oxidizing agent. The tested compound was also light sensitive and was classified as photolabile both in solution and in the solid phase. However, the observed photodegradation in the solid phase was at a much lower level than in the case of photodegradation in solution. The study showed that both air temperature and RH had no significant effect on the stability of the tested substance during storage for 1 month at 100°C (dry heat) as well as during accelerated and intermediate tests. Based on the HPLC/MS/MS analysis, it can be concluded that acyclovir was formed as a degradation product of 6-(4-MeOPh)-TACV.

  12. [A new method for safety monitoring of natural dietary supplements--quality profile].

    PubMed

    Wang, Juan; Wang, Li-Ping; Yang, Da-Jin; Chen, Bo

    2008-07-01

    A new method for safety monitoring of natural dietary supplements--quality profile was proposed. It would convert passive monitoring of synthetic drug to active, and guarantee the security of natural dietary supplements. Preliminary research on quality profile was completed by high performance liquid chromatography (HPLC) and mass spectrometry (MS). HPLC was employed to analyze chemical constituent profiles of natural dietary supplements. The separation was completed on C18 column with acetonitrile and water (0.05% H3PO4) as mobile phase, the detection wavelength was 223 nm. Based on HPLC, stability of quality profile had been studied, and abnormal compounds in quality profile had been analyzed after addition of phenolphthalein, sibutramine, rosiglitazone, glibenclamide and gliclazide. And by MS, detector worked with ESI +, capillary voltage: 3.5 kV, cone voltage: 30 V, extractor voltage: 4 V, RF lens voltage: 0.5 V, source temperature: 105 degrees C, desolvation temperature: 300 degrees C, desolvation gas flow rate: 260 L/h, cone gas flow rate: 50 L/h, full scan mass spectra: m/z 100-600. Abnormal compound in quality profile had been analyzed after addition of N-mono-desmethyl sibutramine. Quality profile based on HPLC had good stability (Similarity > 0.877). Addition of phenolphthalein, sibutramine, rosiglitazone, glibenclamide and gliclazide in natural dietary supplements could be reflected by HPLC, and addition of N-mono-desmethyl sibutramine in natural dietary supplements could be reflected by MS. Quality profile might monitor adulteration of natural dietary supplements, and prevent addition of synthetic drug after "approval".

  13. Stability and oxidation products of hydrolysable tannins in basic conditions detected by HPLC/DAD-ESI/QTOF/MS.

    PubMed

    Tuominen, Anu; Sundman, Terhi

    2013-01-01

    Hydrolysable tannins occur in plants that are used for food or medicine by humans or herbivores. Basic conditions can alter the structures of tannins, that is, the oxidation of phenolic groups can lead to the formation of toxic quinones. Previously, these labile quinones and other oxidation products have been studied with colorimetric or electron paramagnetic resonance methods, which give limited information about products. To study the stability and oxidation products of hydrolysable tannins in basic conditions using HPLC with a diode-array detector (DAD) combined with electrospray ionisation (ESI) and quadrupole time-of-flight (QTOF) MS. Three galloyl glucoses, four galloyl derivatives with different polyols and three ellagitannins were purified from plants. The incubation reactions of tannins were monitored by HPLC/DAD at five pH values and in reduced oxygen conditions. Reaction products were identified based on UV spectra and mass spectral fragmentation obtained with the high-resolution HPLC/DAD-ESI/QTOF/MS. The use of a base-resistant HPLC column enabled injections without the sample pre-treatment and thus detection of short-lived products. Hydrolysable tannins were unstable in basic conditions and half-lives were mostly less than 10 min at pH 10. Degradation rates were faster at pH 11 but slower at milder pH. The HPLC analyses revealed that various products were formed and identified to be the result of hydrolysis, deprotonation and oxidation. Interestingly, the main hydrolysis product was ellagic acid; it was also formed from galloyl glucoses that do not contain oxidatively coupled galloyl groups in their initial structures. HPLD/DAD-ESI/QTOF/MS was an efficient method for the identification of polyphenol oxidation products and showed how different pH conditions determine the fate of hydrolysable tannins. Copyright © 2013 John Wiley & Sons, Ltd.

  14. Physicochemical compatibility of propofol with thiopental sodium.

    PubMed

    Prankerd, R J; Jones, R D

    1996-11-01

    The physicochemical compatibility of propofol and thiopental sodium when mixed together in various ratios and stored was studied. Mixtures of propofol and thiopental sodium in five volume ratios from 1:3 to 3:1 were refrigerated (4 degrees C) for up to seven days and then centrifuged at 2000g for two hours. Droplet sizes were determined at intervals by optical microscopy and laser diffraction, and chemical stability of the 1:1 mixture was evaluated by high-performance liquid chromatography (HPLC). Optical microscopy and laser diffraction indicated negligible changes in droplet size within 48 hours of mixing. A small increase in the width of the frequency distribution of droplet sizes occurred 24-48 hours after mixing for the two mixtures with the lowest propofol concentration. Some coalescence of droplets occurred on centrifugation. These results indicated negligible formation of droplets that might cause embolism after i.v. injection of fresh mixtures (not more than six hours old). A yellow color appearing after 24-48 hours indicated anticipated chemical changes. HPLC of samples stored at 25 degrees C indicated clinically unimportant drug loss after six hours. The mixtures were considered physically stable for not more than 48 hours. Droplet size in mixtures of propofol and thiopental sodium did not increase until at least 24 hours. Drug loss from mixtures containing propofol 5 mg/mL and thiopental sodium 12.5 mg/mL was insignificant for up to eight hours.

  15. Adsorptive behavior and solid-phase microextraction of bare stainless steel sample loop in high performance liquid chromatography.

    PubMed

    Zhang, Wenpeng; Zhang, Zixin; Meng, Jiawei; Zhou, Wei; Chen, Zilin

    2014-10-24

    In this work, we interestingly happened to observe the adsorption of stainless steel sample loop of HPLC. The adsorptive behaviors of the stainless steel loop toward different kinds of compounds were studied, including polycyclic aromatic hydrocarbons (PAHs), halogeno benzenes, aniline derivatives, benzoic acid derivatives, phenols, benzoic acid ethyl ester, benzaldehyde, 1-phenyl-ethanone and phenethyl alcohol. The adsorptive mechanism was probably related to hydrophobic interaction, electron-rich element-metal interaction and hydrogen bond. Universal adsorption of stainless steels was also testified. Inspired by its strong adsorptive capability, bare stainless steel loop was developed as a modification-free in-tube device for solid-phase microextraction (SPME), which served as both the substrate and sorbent and possessed ultra-high strength and stability. Great extraction efficiency toward PAHs was obtained by stainless steel loop without any modification, with enrichment factors of 651-834. By connecting the stainless steel loop onto a six-port valve, an online SPME-HPLC system was set up and an SPME-HPLC method has been validated for determination of PAHs. The method has exceptionally low limits of detection of 0.2-2pg/mL, which is significantly lower than that of reported methods with different kinds of sorbents. Wide linear range (0.5-500 and 2-1000pg/mL), good linearity (R(2)≥0.9987) and good reproducibility (RSD≤2.9%) were also obtained. The proposed method has been applied to determine PAHs in environmental samples. Good recoveries were obtained, ranging from 88.5% to 93.8%. Copyright © 2014 Elsevier B.V. All rights reserved.

  16. Investigations Concerning Hydrolysis and Stabilization of Antiradiation Compounds

    DTIC Science & Technology

    1982-01-01

    a. HPLC Unit A 3 b. HPLC Unit B 3 c. Solvents 3 d. Reagents 3 B. In Vivo Studies 3 C. Microencapsulation 4 1. Materials 4 a... Microencapsulation 63 VI. CONCLUSIONS 64 VII. RECOMMENDATIONS 65 LITERATURE CITED 66 APPENDU A - IN VIVO PILOT STUDIES 67 APPENDIX B...stomach. One convenient method of applying such a coating is microencapsulation , a process which may subject the drug to elevated temperatures

  17. Combined Application of UHPLC-QTOF/MS, HPLC-ELSD and 1 H-NMR Spectroscopy for Quality Assessment of DA-9801, A Standardised Dioscorea Extract.

    PubMed

    Kang, Kyo Bin; Ryu, Jayoung; Cho, Youngwoong; Choi, Sang-Zin; Son, Miwon; Sung, Sang Hyun

    2017-05-01

    DA-9801, a standardised 50% aqueous ethanolic extract of a mixture of Dioscorea japonica and D. nipponica, is a botanical drug candidate for the treatment of diabetic neuropathy, which finished its US phase II clinical trials recently. An advanced quality control method is needed for further development of DA-9801, considering its high contents of both primary and secondary metabolites. Development of a quality assessment strategy for DA-9801, based on the combination of UHPLC-QTOF/MS, HPLC-ELSD, and 1 H-NMR spectroscopy. The method was developed and tested with 15 batch products of DA-9801. The steroidal saponins of DA-9801 were tentatively identified by UHPLC-QTOF/MS and were quantified with the validated HPLC-ELSD method. Primary metabolites of DA-9801 were identified and profiled using 1 H-NMR spectrometry. The batch-to-batch equivalence of DA-9801 was tested with the 1 H-NMR spectra using spectral binning, correlation analysis, and principal component analysis. Six major saponins of DA-9801 were tentatively identified by UHPLC-QTOF/MS. Among them, protodioscin and dioscin were quantified by the validated HPLC-ELSD method. Twenty-six metabolites were identified in 1 H-NMR spectra. The similarity between DA-9801 batches could be evaluated with the NMR spectra of DA-9801. The 1 H-NMR method also revealed that two Dioscorea species contributed distinct amino acids to the contents of DA-9801. This study validates the effectiveness of UHPLC-QTOF/MS, HPLC-ELSD, and 1 H NMR-combined method for quality control of DA-9801 and its crude materials. Copyright © 2016 John Wiley & Sons, Ltd. Copyright © 2016 John Wiley & Sons, Ltd.

  18. Development and validation of a reversed-phase fluorescence HPLC method for determination of bucillamine in human plasma using pre-column derivatization with monobromobimane.

    PubMed

    Lee, Kang Choon; Chun, Young Goo; Kim, Insoo; Shin, Beom Soo; Park, Eun-Seok; Yoo, Sun Dong; Youn, Yu Seok

    2009-07-15

    A simple, specific and sensitive derivatization with monobromobimane (mBrB) and the corresponding HPLC-fluorescence quantitation method for the analysis of bucillamine in human plasma was developed and validated. The analytical procedure involves a simple protein precipitation, pre-column fluorescence derivatization, and separation by reversed-phase high performance liquid chromatography (RP-HPLC). The calibration curve showed good linearity over a wide concentration range (50 ng/mL to 10 microg/mL) in human plasma (r(2)=0.9998). The lower limit of quantitation (LLOQ) was 50 ng/mL. The average precision and accuracy at LLOQ were within 6.3% and 107.6%, respectively. This method was successfully applied to a pharmacokinetic study after oral administration of a dose (300 mg) of bucillamine to 20 healthy Korean volunteers.

  19. Stability of suxamethonium in pharmaceutical solution for injection by validated stability-indicating chromatographic method.

    PubMed

    Beck, William; Kabiche, Sofiane; Balde, Issa-Bella; Carret, Sandra; Fontan, Jean-Eudes; Cisternino, Salvatore; Schlatter, Joël

    2016-12-01

    To assess the stability of pharmaceutical suxamethonium (succinylcholine) solution for injection by validated stability-indicating chromatographic method in vials stored at room temperature. The chromatographic assay was achieved by using a detector wavelength set at 218 nm, a C18 column, and an isocratic mobile phase (100% of water) at a flow rate of 0.6 mL/min for 5 minutes. The method was validated according to the International Conference on Harmonization guidelines with respect to the stability-indicating capacity of the method including linearity, limits of detection and quantitation, precision, accuracy, system suitability, robustness, and forced degradations. Linearity was achieved in the concentration range of 5 to 40 mg/mL with a correlation coefficient higher than 0.999. The limits of detection and quantification were 0.8 and 0.9 mg/mL, respectively. The percentage relative standard deviation for intraday (1.3-1.7) and interday (0.1-2.0) precision was found to be less than 2.1%. Accuracy was assessed by the recovery test of suxamethonium from solution for injection (99.5%-101.2%). Storage of suxamethonium solution for injection vials at ambient temperature (22°C-26°C) for 17 days demonstrated that at least 95% of original suxamethonium concentration remained stable. Copyright © 2016 Elsevier Inc. All rights reserved.

  20. Chitosan-decorated selenium nanoparticles as protein carriers to improve the in vivo half-life of the peptide therapeutic BAY 55-9837 for type 2 diabetes mellitus.

    PubMed

    Rao, Lei; Ma, Yi; Zhuang, Manjiao; Luo, Tianjie; Wang, Yayu; Hong, An

    2014-01-01

    As a potential protein therapeutic for type 2 diabetes mellitus (T2DM), BAY 55-9837 is limited by poor stability and a very short half-life in vivo. The purpose of this study was to construct a novel nanostructured biomaterial by conjugating BAY 55-9837 to chitosan-decorated selenium nanoparticles (CS-SeNPs) to prolong the in vivo half-life of BAY 55-9837 by reducing its renal clearance rate. BAY 55-9837-loaded CS-SeNPs (BAY-CS-SeNPs) were prepared, and their surface morphology, particle size, zeta potential, and structure were characterized. The stability, protein-loading rate, and in vitro release of BAY 55-9837 from CS-SeNPs were also quantified. Additionally, a sensitive high-performance liquid chromatography (HPLC) assay was developed for the quantification of BAY 55-9837 in mouse plasma. Thereafter, mice were injected via the tail vein with either BAY 55-9837 or BAY-CS-SeNPs, and the plasma concentration of BAY 55-9837 was determined via our validated HPLC method at different time intervals postinjection. Relevant in vivo pharmacokinetic parameters (half-life, area under the curve from time 0 to last sampling point, observed clearance) were then calculated and analyzed. BAY-CS-SeNPs were successfully synthesized, with diameters of approximately 200 nm. BAY-CS-SeNPs displayed good stability with a high protein-loading rate, and the release process of BAY 55-9837 from the CS-SeNPs lasted for over 70 hours, with the cumulative release reaching 78.9%. Moreover, the conjugation of CS-SeNPs to BAY 55-9837 significantly reduced its renal clearance to a rate of 1.56 mL/h and extended its half-life to 20.81 hours. In summary, our work provides a simple method for reducing the renal clearance rate and extending the half-life of BAY 55-9837 in vivo by utilizing CS-SeNPs as nanocarriers.

  1. Physical and chemical stability of high-dose ifosfamide and mesna for prolonged 14-day continuous infusion.

    PubMed

    Zhang, YanPing; Kawedia, Jitesh D; Myers, Alan L; McIntyre, Chelsey M; Anderson, Peter M; Kramer, Mark A; Culotta, Kirk S

    2014-02-01

    Ifosfamide plus mesna have been used recently in a high-dose regimen that allows this chemotherapy to be given to outpatients with less toxicity over 14 days using a portable pump. However, there is a need for published stability information. The aim of this study was to investigate the physicochemical stability of ifosfamide with mesna in normal saline at room temperature over a prolonged period of 14 days. Infusion solutions of 1:1 ifosfamide and mesna at final concentrations of 10, 20 and 30 mg/mL were prepared with 0.9% sodium chloride in PVC bags. Solutions were stored at room temperature. Concentrations of ifosfamide and mesna were measured at 0 and 1, 3, 7 and 14 days using a stability-indicating reversed phase high-performance liquid chromatography (HPLC) assay with ultraviolet detection. Ifosfamide and mesna were both physicochemically stable (>94%) for 14 days in all tested infusion solutions (10, 20 and 30 mg/mL). Our stability data indicate that ifosfamide and mesna (1:1) combination can be administered as a prolonged continuous infusion with portable pump in an outpatient setting without replacement of the infusion bag. We suggest 20 mg/mL as a reasonable concentration for infusion rates of about 2-4 cc/hr over prolonged periods of time.

  2. HPLC-MS/MS method for dexmedetomidine quantification with Design of Experiments approach: application to pediatric pharmacokinetic study.

    PubMed

    Szerkus, Oliwia; Struck-Lewicka, Wiktoria; Kordalewska, Marta; Bartosińska, Ewa; Bujak, Renata; Borsuk, Agnieszka; Bienert, Agnieszka; Bartkowska-Śniatkowska, Alicja; Warzybok, Justyna; Wiczling, Paweł; Nasal, Antoni; Kaliszan, Roman; Markuszewski, Michał Jan; Siluk, Danuta

    2017-02-01

    The purpose of this work was to develop and validate a rapid and robust LC-MS/MS method for the determination of dexmedetomidine (DEX) in plasma, suitable for analysis of a large number of samples. Systematic approach, Design of Experiments, was applied to optimize ESI source parameters and to evaluate method robustness, therefore, a rapid, stable and cost-effective assay was developed. The method was validated according to US FDA guidelines. LLOQ was determined at 5 pg/ml. The assay was linear over the examined concentration range (5-2500 pg/ml), Results: Experimental design approach was applied for optimization of ESI source parameters and evaluation of method robustness. The method was validated according to the US FDA guidelines. LLOQ was determined at 5 pg/ml. The assay was linear over the examined concentration range (R 2 > 0.98). The accuracies, intra- and interday precisions were less than 15%. The stability data confirmed reliable behavior of DEX under tested conditions. Application of Design of Experiments approach allowed for fast and efficient analytical method development and validation as well as for reduced usage of chemicals necessary for regular method optimization. The proposed technique was applied to determination of DEX pharmacokinetics in pediatric patients undergoing long-term sedation in the intensive care unit.

  3. Determination of Major Phenolic Compounds in Echinacea spp. Raw Materials and Finished Products by High-Performance Liquid Chromatography with Ultraviolet Detection: Single-Laboratory Validation Matrix Extension

    PubMed Central

    Brown, Paula N.; Chan, Michael; Paley, Lori; Betz, Joseph M.

    2013-01-01

    A method previously validated to determine caftaric acid, chlorogenic acid, cynarin, echinacoside, and cichoric acid in echinacea raw materials has been successfully applied to dry extract and liquid tincture products in response to North American consumer needs. Single-laboratory validation was used to assess the repeatability, accuracy, selectivity, LOD, LOQ, analyte stability (ruggedness), and linearity of the method, with emphasis on finished products. Repeatability precision for each phenolic compound was between 1.04 and 5.65% RSD, with HorRat values between 0.30 and 1.39 for raw and dry extract finished products. HorRat values for tinctures were between 0.09 and 1.10. Accuracy of the method was determined through spike recovery studies. Recovery of each compound from raw material negative control (ginseng) was between 90 and 114%, while recovery from the finished product negative control (maltodextrin and magnesium stearate) was between 97 and 103%. A study was conducted to determine if cichoric acid, a major phenolic component of Echinacea purpurea (L.) Moench and E. angustifolia DC, degrades during sample preparation (extraction) and HPLC analysis. No significant degradation was observed over an extended testing period using the validated method. PMID:22165004

  4. Determination of major phenolic compounds in Echinacea spp. raw materials and finished products by high-performance liquid chromatography with ultraviolet detection: single-laboratory validation matrix extension.

    PubMed

    Brown, Paula N; Chan, Michael; Paley, Lori; Betz, Joseph M

    2011-01-01

    A method previously validated to determine caftaric acid, chlorogenic acid, cynarin, echinacoside, and cichoric acid in echinacea raw materials has been successfully applied to dry extract and liquid tincture products in response to North American consumer needs. Single-laboratory validation was used to assess the repeatability, accuracy, selectivity, LOD, LOQ, analyte stability (ruggedness), and linearity of the method, with emphasis on finished products. Repeatability precision for each phenolic compound was between 1.04 and 5.65% RSD, with HorRat values between 0.30 and 1.39 for raw and dry extract finished products. HorRat values for tinctures were between 0.09 and 1.10. Accuracy of the method was determined through spike recovery studies. Recovery of each compound from raw material negative control (ginseng) was between 90 and 114%, while recovery from the finished product negative control (maltodextrin and magnesium stearate) was between 97 and 103%. A study was conducted to determine if cichoric acid, a major phenolic component of Echinacea purpurea (L.) Moench and E. angustifolia DC, degrades during sample preparation (extraction) and HPLC analysis. No significant degradation was observed over an extended testing period using the validated method.

  5. Temperature dependence of autoxidation of perilla oil and tocopherol degradation.

    PubMed

    Wang, Seonyeong; Hwang, Hyunsuk; Yoon, Sukhoo; Choe, Eunok

    2010-08-01

    Temperature dependence of the autoxidation of perilla oil and tocopherol degradation was studied with corn oil as a reference. The oils were oxidized in the dark at 20, 40, 60, and 80 degrees C. Oil oxidation was determined by peroxide and conjugated dienoic acid values. Tocopherols in the oils were quantified by HPLC. The oxidation of both oils increased with oxidation time and temperature. Induction periods for oil autoxidation decreased with temperature, and were longer in corn oil than in perilla oil, indicating higher sensitivity of perilla oil to oxidation. However, time lag for tocopherol degradation was longer in perilla oil, indicating higher stability of tocopherols in perilla oil than in corn oil. Activation energies for oil autoxidation and tocopherol degradation were higher in perilla oil (23.9 to 24.2, 9.8 kcal/mol, respectively) than in corn oil (12.5 to 15.8, 8.8 kcal/mol, respectively) indicating higher temperature-dependence in perilla oil. Higher stability of tocopherols in perilla oil was highly related with polyphenols. The study suggests that more careful temperature control is required to decrease the autoxidation of perilla oil than that of corn oil, and polyphenols contributed to the oxidative stability of perilla oil by protecting tocopherols from degradation, especially at the early stage of oil autoxidation.

  6. Development and validation of an RP-HPLC method for the quantitation of odanacatib in rat and human plasma and its application to a pharmacokinetic study.

    PubMed

    Police, Anitha; Gurav, Sandip; Dhiman, Vinay; Zainuddin, Mohd; Bhamidipati, Ravi Kanth; Rajagopal, Sriram; Mullangi, Ramesh

    2015-11-01

    A simple, specific, sensitive and reproducible high-performance liquid chromatography (HPLC) assay method has been developed and validated for the estimation of odanacatib in rat and human plasma. The bioanalytical procedure involves extraction of odanacatib and itraconazole (internal standard, IS) from a 200 μL plasma aliquot with simple liquid-liquid extraction process. Chromatographic separation was achieved on a Symmetry Shield RP18 using an isocratic mobile phase at a flow rate of 0.7 mL/min. The UV detection wave length was 268 nm. Odanacatib and IS eluted at 5.5 and 8.6 min, respectively with a total run time of 10 min. Method validation was performed as per US Food and Drug Administration guidelines and the results met the acceptance criteria. The calibration curve was linear over a concentration range of 50.9-2037 ng/mL (r(2) = 0.994). The intra- and inter-day precisions were in the range of 2.06-5.11 and 5.84-13.1%, respectively, in rat plasma and 2.38-7.90 and 6.39-10.2%, respectively, in human plasma. The validated HPLC method was successfully applied to a pharmacokinetic study in rats. Copyright © 2015 John Wiley & Sons, Ltd.

  7. Stability of ramipril in water, apple juice, and applesauce.

    PubMed

    Allen, L V; Stiles, M L; Prince, S J; McLaury, H J; Sylvestri, M F

    1995-11-01

    The stability of ramipril in water, in apple juice, and in applesauce was studied. The contents of a single capsule each of ramipril 1.25, 2.5, and 5 mg were mixed in glass beakers with 120 mL of deionized and filtered water, apple juice, or applesauce. Each mixture was apportioned into 10 120-mL amber polyethylene terephthalate (PET) containers. Five of the containers in each set were stored at 23 degrees C, and samples were taken at 0, 1, 2, 6, 12, and 24 hours. The other five containers were stored at 3 degrees C, and samples were taken at 4, 8, 12, 24, and 48 hours. The samples were analyzed for ramipril concentration by stability-indicating high-performance liquid chromatography (HPLC). The quantity of drug remaining in the PET container after "administration" was determined by mixing the contents of single 5-mg ramipril capsules with 60 mL of apple juice, pouring the mixture into a waste receptacle, rinsing the PET container three separate times with 10 mL of water, and analyzing the pooled fluid from these rinses for ramipril concentration by HPLC. Under no condition did the percentage of ramipril remaining drop below 90%. No peaks for degradation products appeared in the chromatograms. The mean +/- S.D. quantity of ramipril remaining in the PET containers after draining was 0.3 +/- 0.3% for the apple juice. Ramipril from 1.25-, 2.5-, and 5-mg capsules mixed in water, in apple juice, and in applesauce was stable for 24 hours at 23 degrees C and for 48 hours at 3 degrees C.

  8. Stability of an extemporaneous alcohol-free melatonin suspension.

    PubMed

    Johnson, Cary E; Cober, Mary Petrea; Thome, Tennille; Rouse, Emily

    2011-03-01

    The stability of alcohol-free oral suspensions of melatonin 1 mg/mL, extemporaneously prepared from two commercially available melatonin tablet products, was studied. Four 1-mg/mL melatonin suspensions were prepared. Formulations A and B contained 20 crushed 3-mg tablets of melatonin combined with a 1:1 mixture of Ora-Plus and either Ora-Sweet or Ora-Sweet SF to produce a volume of 60 mL. Formulations C and D were prepared by crushing 20 combination tablets containing melatonin 3 mg and pyridoxine hydrochloride 10 mg and then combining the powder with a 1:1 mixture of Ora-Plus and either Ora-Sweet or Ora-Sweet SF to produce a 60-mL volume. The suspensions were prepared in triplicate and stored at room temperature in amber plastic prescription bottles. Immediately after preparation and on days 7, 15, 30, 60, and 90, the samples were assayed in duplicate by stability-indicating high-performance liquid chromatography (HPLC). The samples were also evaluated for any changes in color, odor, and taste. HPLC analysis demonstrated that at least 94% of the initial melatonin concentration in formulations A and B, and at least 98% of that in formulations C and D, remained throughout the 90-day study period. Detectable changes in color, odor, or taste occurred in all of the formulations. Extemporaneously prepared, alcohol-free, 1-mg/mL suspensions of melatonin and melatonin-pyridoxine hydrochloride in a 1:1 mixture of Ora-Plus and either Ora Sweet or Ora Sweet SF were stable for at least 90 days when stored in 2-oz amber plastic bottles at room temperature.

  9. Development and validation of a stability-indicating capillary zone electrophoretic method for the assessment of entecavir and its correlation with liquid chromatographic methods.

    PubMed

    Dalmora, Sergio Luiz; Nogueira, Daniele Rubert; D'Avila, Felipe Bianchini; Souto, Ricardo Bizogne; Leal, Diogo Paim

    2011-01-01

    A stability-indicating capillary zone electrophoresis (CZE) method was validated for the analysis of entecavir in pharmaceutical formulations, using nimesulide as an internal standard. A fused-silica capillary (50 µm i.d.; effective length, 40 cm) was used while being maintained at 25°C; the applied voltage was 25 kV. A background electrolyte solution consisted of a 20 mM sodium tetraborate solution at pH 10. Injections were performed using a pressure mode at 50 mbar for 5 s, with detection at 216 nm. The specificity and stability-indicating capability were proven through forced degradation studies, evaluating also the in vitro cytotoxicity test of the degraded products. The method was linear over the concentration range of 1-200 µg mL(-1) (r(2) = 0.9999), and was applied for the analysis of entecavir in tablet dosage forms. The results were correlated to those of validated conventional and fast LC methods, showing non-significant differences (p > 0.05).

  10. Multi-wavelength spectrophotometric analysis for detection of xanthochromia in cerebrospinal fluid and accuracy for the diagnosis of subarachnoid hemorrhage.

    PubMed

    Smith, Andrew; Wu, Alan H B; Lynch, Kara L; Ko, Nerissa; Grenache, David G

    2013-09-23

    Cerebrospinal fluid (CSF) was examined for bilirubin, an important indicator for diagnosis of subarachnoid hemorrhage (SAH). A multi-wavelength (340, 415, and 460 nm) spectrophotometric assay was developed for the quantitative measurement of bilirubin in CSF, enabling the mathematical correction for absorbance of hemoglobin and proteins. Bilirubin and hemoglobin results were correlated to HPLC and a standard colorimetric assay, respectively. A subset of samples was sent for an absorbance reading at 450 nm following baseline correction. The multi-wavelength bilirubin assay was validated on 70 patients with confirmed SAH and 70 patients with neurologic symptoms who ruled out for SAH. The multi-wavelength spectrophometric assay demonstrated no interferences due to proteins (albumin) up to 30 g/l or oxyhemoglobin up to 260 mg/l. The assay limit of detection was 0.2 mg/l, linear to 20 mg/l, and CVs ranged from 1 to 6% at bilirubin concentrations of 0.84 and 2.1mg/l. The spectrophotometric assay correlated to HPLC and the colorimetric assay for bilirubin and hemoglobin, respectively. Results also correlated to the absorbance method (with removal of samples with high hemoglobin and proteins). The area under the ROC curve for diagnosis of SAH was 0.971 and 0.954 for the HPLC and spectrophotometric assay, respectively. At a cutoff of 0.2mg/l, the clinical specificity was 100% for both assays, and the clinical sensitivity was 94.3% and 88.6% for SAH for the HPLC and spectrophotometric asays, respectively. The multi-wavelength spectrophotometric assay is an objective alternative to visual inspection, HPLC, and absorbance for CSF bilirubin. Copyright © 2013 Elsevier B.V. All rights reserved.

  11. HPLC-DAD and HPLC-ESI-MS/MS methods for metabolite profiling of propolis extracts.

    PubMed

    Pellati, Federica; Orlandini, Giulia; Pinetti, Diego; Benvenuti, Stefania

    2011-07-15

    In this study, the composition of polyphenols (phenolic acids and flavonoids) in propolis extracts was investigated by HPLC-DAD and HPLC-ESI-MS/MS by comparing the performance of ion trap and triple quadrupole mass analyzers. The analyses were carried out on an Ascentis C(18) column (250mm×4.6mm I.D., 5μm), with a mobile phase composed by 0.1% formic acid in water and acetonitrile. Overall, the UV spectra, the MS and MS/MS data allowed the identification of 40 compounds. In the case of flavonoids, the triple quadrupole mass analyzer provided more collision energy if compared with the ion trap, originating product ions at best sensitivity. The HPLC method was validated in agreement with ICH guidelines: the correlation coefficients were >0.998; the limit of detection was in the range 1.6-4.6μg/ml; the recovery range was 96-105%; the intra- and inter-day %RSD values for retention times and peak areas were found to be <0.3 and 1.9%, respectively. The developed technique was applied to the analysis of hydroalcoholic extracts of propolis available on the Italian market. Although the chromatographic profile of the analyzed samples was similar, the quantitative analysis indicated that there is a great variability in the amount of the active compounds: the content of total phenolic acids ranged from 0.17 to 16.67mg/ml and the level of total flavonoids from 2.48 to 41.10mg/ml. The proposed method can be considered suitable for the phytochemical analysis of propolis extracts used in phytotherapy. Copyright © 2011 Elsevier B.V. All rights reserved.

  12. High perfomance liquid chromatography fingerprint analysis for quality control of brotowali (Tinospora crispa)

    NASA Astrophysics Data System (ADS)

    Syarifah, V. B.; Rafi, M.; Wahyuni, W. T.

    2017-05-01

    Brotowali (Tinospora crispa) is widely used in Indonesia as ingredient of herbal medicine formulation. To ensure the quality, safety, and efficacy of herbal medicine products, its chemical constituents should be continuously evaluated. High performance liquid chromatography (HPLC) fingerprint is one of powerful technique for this quality control process. In this study, HPLC fingerprint analysis method was developed for quality control of brotowali. HPLC analysis was performed in C18 column and detection was performed using photodiode array detector. The optimum mobile phase for brotowali fingerprint was acetonitrile (ACN) and 0.1% formic acid in gradient elution mode at a flow rate of 1 mL/min. The number of peaks detected in HPLC fingerprint of brotowali was 32 peaks and 23 peaks for stems and leaves, respectively. Berberine as marker compound was detected at retention time of 20.525 minutes. Evaluation of analytical performance including precision, reproducibility, and stability prove that this HPLC fingerprint analysis was reliable and could be applied for quality control of brotowali.

  13. Simultaneous analysis of 17 diuretics in dietary supplements by HPLC and LC-MS/MS.

    PubMed

    Woo, H; Kim, J W; Han, K M; Lee, J H; Hwang, I S; Lee, J H; Kim, J; Kweon, S J; Cho, S; Chae, K R; Han, S Y; Kim, J

    2013-01-01

    In order to test health foods for illegally added diuretics for weight loss, we developed simple, rapid, selective, and sensitive methods using HPLC and LC-MS/MS for the simultaneous analysis of 17 diuretics in dietary supplements. HPLC conditions were set with a Capcell-pak C18, using a mobile phase consisting of gradient conditions, UV detection at 254 nm and validated for linearity (r(2)> 0.999), precision (CV ≤ 3%), recoveries (90.4-102.8%) and reproducibility. Identification and quantification of 17 diuretics were accomplished by ion-spray LC-MS/MS using multiple reaction monitoring (MRM). The chromatographic separation was carried out under the reversed-phase mechanism on an HSS-T3 column. The LC-MS/MS method was validated for linearity (r(2)> 0.99) and precision (CV < 13%). Sixteen dietary supplements were tested with the developed methods. Diuretics were not detected in all samples. Extraction recovery was also investigated and the extraction recoveries in different formulations were from 88% to 110% and from 81% to 116% using HPLC and LC-MS/MS, respectively. There was no significant difference in recoveries in the type of dietary supplements. Based on this result, the developed methods to monitor illegal drug adulterations in dietary supplements using HPLC and LC-MS/MS are simple, fast and reliable. Therefore, it is applicable to routine drug-adulteration screening.

  14. Simultaneous HPLC quantitative analysis of active compounds in leaves of Moringa oleifera Lam.

    PubMed

    Vongsak, Boonyadist; Sithisarn, Pongtip; Gritsanapan, Wandee

    2014-08-01

    Moringa oleifera Lam. has been used as a traditional medicine for the treatment of numerous diseases. A simultaneous high-performance liquid chromatography (HPLC) analysis was developed and validated for the determination of the contents of crypto-chlorogenic acid, isoquercetin and astragalin, the primary antioxidative compounds, in M. oleifera leaves. HPLC analysis was successfully conducted by using a Hypersil BDS C18 column, eluted with a gradient of methanol-1% acetic acid with a flow rate of 1 mL/min, and detected at 334 nm. Parameters for the validation included linearity, precision, accuracy and limits of detection and quantitation. The developed HPLC method was precise, with relative standard deviation < 2%. The recovery values of crypto-chlorogenic acid, isoquercetin and astragalin in M. oleifera leaf extracts were 98.50, 98.47 and 98.59%, respectively. The average contents of these compounds in the dried ethanolic extracts of the leaves of M. oleifera collected from different regions of Thailand were 0.081, 0.120 and 0.153% (w/w), respectively. The developed HPLC method was appropriate and practical for the simultaneous analysis of crypto-chlorogenic acid, isoquercetin and astragalin in the leaf extract of M. oleifera. This work is valuable as guidance for the standardization of the leaf extracts and pharmaceutical products of M. oleifera. © The Author [2013]. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.

  15. Carotenoid stability during production and storage of tomato juice made from tomatoes with diverse pigment profiles measured by infrared spectroscopy.

    PubMed

    Rubio-Diaz, Daniel E; Santos, Alejandra; Francis, David M; Rodriguez-Saona, Luis E

    2010-08-11

    Chemical changes in carotenoids and lipids were studied during production and storage of canned tomato juice using ATR infrared spectroscopy and HPLC. Samples from 10 groups of tomatoes with different carotenoid profiles were analyzed fresh, after hot-break and screening, after canning, and at five different time points during 1 year of storage. An apparent increase of carotenoids was observed after hot-break due to improved extraction efficiency. This increase was accompanied by some degree of lipid oxidation and carotenoid isomerization. Canning produced the most intense changes in the lipid profile with breakdown of triglycerides ( approximately 1743 cm(-1)), formation of fatty acids ( approximately 1712 cm(-1)), and degradation and isomerization of trans-carotenoids ( approximately 960 and approximately 3006 cm(-1)). Isomerization was corroborated by the relative increase of HPLC areas corresponding to carotenoid cis isomers. Canning reduced trans-lycopene, trans-delta-carotene, trans-beta-carotene, and trans-lutein by 30, 34, 43, and 67%, respectively. HPLC data indicate that canning causes a drastic reduction of tetra-cis-lycopene and promotes its isomerization to other geometric forms, including all-trans-lycopene. Infrared spectra of tomato juice lipid fractions correlated well with the number of days in storage (SECV < 11 days, r values > 0.99), demonstrating continuous degradation of lipids. Results demonstrated that individual carotenoids and their isomeric forms behave differently during production and storage of canned tomato juice. Information collected by infrared spectroscopy complemented well that of HPLC, providing marker bands to further the understanding of chemical changes taking place during processing and storage of tomato juice.

  16. Validation of an HPLC method for the determination of fleroxacin and its photo-degradation products in pharmaceutical forms.

    PubMed

    Djurdjevic, Predrag; Laban, Aleksandra; Jelikic-Stankov, Milena

    2004-01-01

    HPLC determination of fleroxacin in dosage forms was carried out using either reversed-phase column YMC pack ODS-AQ or Supelco LC Hisep shielded hydrophobic phase column, with UV detection at 280 nm. The mobile phase for ODS column consisted of 50:50:0.5 v/v/v and for Hisep column 15:85:0.5 v/v/v acetonitrile-water-triethylamine. The pH of the mobile phase was adjusted to 6.30 for ODS column and to 6.85 for Hisep column, with H3PO4. Linear response was obtained in the concentration range of fleroxacin between 0.01 and 1.30 micrograms/mL. Detection limit was 4.8 ng/mL. Recovery test in the determination of fleroxacin in "Quinodis" tablets (Hoffmann La Roche, nominal mass 400 or 200 mg) was 98-101% for both columns. The effect of the composition and pH of the mobile phase on spectra, retention time and dissociation constants of fleroxacin was discussed. The proposed method could be also used for separation of the photo-degradation products of fleroxacin. Ten degradation products were separated on the ODS-AQ column, thus confirming the suitability of the proposed method for stability study of fleroxacin in pharmaceuticals.

  17. Simultaneous quantification of coumarins, flavonoids and limonoids in Fructus Citri Sarcodactylis by high performance liquid chromatography coupled with diode array detector.

    PubMed

    Chu, Jun; Li, Song-Lin; Yin, Zhi-Qi; Ye, Wen-Cai; Zhang, Qing-Wen

    2012-07-01

    A high performance liquid chromatography coupled with diode array detector (HPLC-DAD) method was developed for simultaneous quantification of eleven major bioactive components including six coumarins, three flavonoids and two limonoids in Fructus Citri Sarcodactylis. The analysis was performed on a Cosmosil 5 C(18)-MS-II column (4.6 mm × 250 mm, 5 μm) with water-acetonitrile gradient elution. The method was validated in terms of linearity, sensitivity, precision, stability and accuracy. It was found that the calibration curves for all analytes showed good linearity (R(2)>0.9993) within the test ranges. The overall limit of detection (LOD) and limit of quantification (LOQ) were less than 3.0 and 10.2 ng. The relative standard deviations (RSDs) for intra- and inter-day repeatability were not more than 4.99% and 4.92%, respectively. The sample was stable for at least 48 h. The spike recoveries of eleven components were 95.1-104.9%. The established method was successfully applied to determine eleven components in three samples from different locations. The results showed that the newly developed HPLC-DAD method was linear, sensitive, precise and accurate, and could be used for quality control of Fructus Citri Sarcodactylis. Copyright © 2012 Elsevier B.V. All rights reserved.

  18. Identification and simultaneous quantification of five alkaloids in Piper longum L. by HPLC-ESI-MS(n) and UFLC-ESI-MS/MS and their application to Piper nigrum L.

    PubMed

    Liu, Hao-Long; Luo, Rong; Chen, Xiao-Qing; Ba, Yin-Ying; Zheng, Li; Guo, Wei-Wei; Wu, Xia

    2015-06-15

    A simple, effective and suitable UFLC-ESI-MS/MS method was firstly developed to simultaneously determine five characteristic constituents (piperine, piperlonguminine, Δα,β-dihydropiperlonguminine, pellitorine and piperanine) of Piper longum L. The total alkaloids of P. longum L. was prepared. The alkaloid contents of Piper nigrum L. and P. longum L. were compared. The analysis was carried out in multiple reaction monitoring scan mode. The method showed a good specificity, linearity (R(2)>0.995), stability (RSD<2.53%), repeatability (RSD<2.58%), and recovery (90.0-103.5%). The limits of detection and limits of quantification of five alkaloids were in the range of 0.02-0.03 and 0.05-0.10 ng/mL, respectively. The intra- and inter-day precision was less than 9.30% and 9.55%, respectively. The validation results confirmed that the method could simultaneously determine the target alkaloids in the sample. Furthermore, the identities of the alkaloids were verified by HPLC-ESI-MS/MS. Compared with P. nigrum, P. longum had lower piperine content but was enriched in the other four alkaloids. Copyright © 2015 Elsevier Ltd. All rights reserved.

  19. Microwave-assisted extraction of herbacetin diglucoside from flax (Linum usitatissimum L.) seed cakes and its quantification using an RP-HPLC-UV system.

    PubMed

    Fliniaux, Ophélie; Corbin, Cyrielle; Ramsay, Aina; Renouard, Sullivan; Beejmohun, Vickram; Doussot, Joël; Falguières, Annie; Ferroud, Clotilde; Lamblin, Frédéric; Lainé, Eric; Roscher, Albrecht; Grand, Eric; Mesnard, François; Hano, Christophe

    2014-03-10

    Flax (Linum usitatissimum L.) seeds are widely used for oil extraction and the cold-pressed flaxseed (or linseed) cakes obtained during this process constitute a valuable by-product. The flavonol herbacetin diglucoside (HDG) has been previously reported as a constituent of the flaxseed lignan macromolecule linked through ester bonds to the linker molecule hydroxymethylglutaric acid. In this context, the development and validation of a new approach using microwave-assisted extraction (MAE) of HDG from flaxseed cakes followed by quantification with a reverse-phase HPLC system with UV detection was purposed. The experimental parameters affecting the HDG extraction yield, such as microwave power, extraction time and sodium hydroxide concentration, from the lignan macromolecule were optimized. A maximum HDG concentration of 5.76 mg/g DW in flaxseed cakes was measured following an irradiation time of 6 min, for a microwave power of 150 W using a direct extraction in 0.1 M NaOH in 70% (v/v) aqueous methanol. The optimized method was proven to be rapid and reliable in terms of precision, repeatability, stability and accuracy for the extraction of HDG. Comparison with a conventional extraction method demonstrated that MAE is more effective and less time-consuming.

  20. Isolation and identification of arctiin and arctigenin in leaves of burdock (Arctium lappa L.) by polyamide column chromatography in combination with HPLC-ESI/MS.

    PubMed

    Liu, Shiming; Chen, Kaoshan; Schliemann, Willibald; Strack, Dieter

    2005-01-01

    A simple method involving polyamide column chromatography in combination with HPLC-PAD and HPLC-ESI/MS for isolating and identifying two kinds of lignans, arctiin and arctigenin, in the leaves of burdock (Arctium lappa L.) has been established. After extraction of burdock leaves with 80% methanol, the aqueous phase of crude extracts was partitioned between water and chloroform and the aqueous phase was fractionated on a polyamide glass column. The fraction, eluting with 100% methanol, was concentrated and gave a white precipitate at 4 degrees C from which two main compounds were purified by semi-preparative HPLC. In comparison with the UV and ESI-MS spectra and the HPLC retention time of authentic standards, the compounds were determined to be arctiin and arctigenin. The extraction/separation technique was validated using an internal standard method.

  1. On-line MSPD-SPE-HPLC/FLD analysis of polycyclic aromatic hydrocarbons in bovine tissues.

    PubMed

    Gutiérrez-Valencia, Tania M; García de Llasera, Martha P

    2017-05-15

    A fast method was optimized and validated for simultaneous trace determination of four polycyclic aromatic hydrocarbons: benzo[a]anthracene, benzo[b]fluoranthene, benzo[k]fluoranthene and benzo[a]pyrene in bovine tissues. The determination was performed by matrix solid-phase dispersion (MSPD) coupled on-line to solid phase extraction (SPE) and high performance liquid chromatography (HPLC) with fluorescence detection (FLD). The sample was dispersed on C 18 silica sorbent and then the on-line MSPD-SPE-HPLC/FLD method was applied. Several parameters were optimized: cleaning and elution sequences applied to the MSPD cartridge, the flow rate and dilution of extract used for SPE loading. The on-line method was validated over a concentration range of 0.1-0.6ngg -1 obtaining good linearity (r⩾0.998) and precision (RSD)⩽10%. Recovery ranged from 96 to 99% and the limits of detection were 0.012ngg -1 . This methodology was applied to liver samples from unhealthy animals. The results demonstrate that MSDP-SPE-HPLC/FLD method provides reliable, sensitive, accurate and fast data to the food control. Copyright © 2016 Elsevier Ltd. All rights reserved.

  2. Bio-assay guided isolation of α-glucosidase inhibitory constituents from Hibiscus mutabilis leaves.

    PubMed

    Kumar, Deepak; Kumar, Hemanth; Vedasiromoni, J R; Pal, Bikas C

    2012-01-01

    The increasing demand for natural-product-based medicines and health-care products for the management of diabetes encouraged investigation of this commonly available Indian plant. To establish the anti-diabetic (α-glucosidase inhibitory) activity of H. mutabilis leaf extract, isolate and identify the constituents responsible for the activity, and validate a HPLC method for quantification of the active constituents for standardisation of the extract. The methanolic extract of leaves was partitioned between water, n-butanol and ethyl acetate. Bio-assay guided fractionation, based on inhibition of α-glucosidase, allowed isolation and identification of the active components. The active components were quantified using RP-HPLC-DAD validated for linearity, limit of detection, limit of quantification, precision, accuracy and robustness for this plant extract and the partitioned fractions. Ferulic acid and caffeic acid were identified as the α-glucosidase inhibitors present in H. mutabilis. They were partitioned into an ethyl acetate fraction. The HPLC-DAD calibration curve showed good linearity (r² > 0.99). For the recovery studies the %RSD was less than 2%. The interday and intraday variations were found to be less than 4% RSD for retention time and response. The identification of α-glucosidase inhibition activity in H. mutabilis supports further investigations into the possible use of the plant for the management of diabetes. The HPLC method validated for these extracts will be useful in future research with the plant. Copyright © 2011 John Wiley & Sons, Ltd.

  3. Speciation of Bio-Available Iodine in Abalone (Haliotis discus hannai) by High-Performance Liquid Chromatography Hyphenated with Inductively Coupled Plasma-Mass Spectrometry Using an In Vitro Method.

    PubMed

    Doh, Han Sol; Park, Hyun Jin

    2018-06-01

    Abalone is one of the most valuable marine products found in East Asia because it is rich in nutritious substances including iodine. In this study, the in vitro dialyzability approach was used to assess the bio-available iodine species in abalone. Iodide, iodate, 3-iodo-L-tyrosine (MIT), and 3,5-diiodo-L-tyrosine (DIT) were separated by high-performance liquid chromatography hyphenated with inductively coupled plasma-mass spectrometry (HPLC-ICP-MS). To assure the consistency, reliability, and accuracy of the data, the method was validated. Comparison of the total iodine in abalone muscle and viscera indicated that abalone muscle showed greater digestion/absorption efficiency than abalone viscera (digestion efficiency: 68.13 ± 2.59% and 47.88 ± 5.76% and absorption efficiency: 59.78 ± 2.93% and 35.12 ± 1.43% for abalone viscera and muscle, respectively). However, evaluation of the sum of the analyzed iodine species targeted in this study by HPLC-ICP-MS indicated that abalone muscle showed lower digestion efficiency and similar absorption efficiency compared to that of abalone viscera (digestion efficiency: 35.52 ± 5.41% and 28.84 ± 1.83%; absorption efficiency: 23.56 ± 4.38% and 27.56 ± 1.51% for abalone viscera and muscle, respectively). The main forms of iodine detected in abalone muscle were iodide and MIT, whereas iodide was the major form in abalone viscera. The bio-available iodine in abalone was quantified via an in vitro method employing HPLC-ICP-MS. The results of this study indicated that abalone is feasible as a new iodine source and may prospectively find application in iodine-fortified foods. © 2018 Institute of Food Technologists®.

  4. Validation of HPLC and UV spectrophotometric methods for the determination of meropenem in pharmaceutical dosage form.

    PubMed

    Mendez, Andreas S L; Steppe, Martin; Schapoval, Elfrides E S

    2003-12-04

    A high-performance liquid chromatographic method and a UV spectrophotometric method for the quantitative determination of meropenem, a highly active carbapenem antibiotic, in powder for injection were developed in present work. The parameters linearity, precision, accuracy, specificity, robustness, limit of detection and limit of quantitation were studied according to International Conference on Harmonization guidelines. Chromatography was carried out by reversed-phase technique on an RP-18 column with a mobile phase composed of 30 mM monobasic phosphate buffer and acetonitrile (90:10; v/v), adjusted to pH 3.0 with orthophosphoric acid. The UV spectrophotometric method was performed at 298 nm. The samples were prepared in water and the stability of meropenem in aqueous solution at 4 and 25 degrees C was studied. The results were satisfactory with good stability after 24 h at 4 degrees C. Statistical analysis by Student's t-test showed no significant difference between the results obtained by the two methods. The proposed methods are highly sensitive, precise and accurate and can be used for the reliable quantitation of meropenem in pharmaceutical dosage form.

  5. Analytical method for the simultaneous determination of polyfunctional amines used as monomers in the manufacture of food packaging materials.

    PubMed

    Paseiro-Cerrato, R; de Quirós, A Rodríguez-Bernaldo; Sendón, Raquel; Bustos, Juana; Ruíz, E; Cruz, J M; Paseiro-Losada, P

    2011-10-07

    This paper describes the development of a multi-analyte method for the determination of polyfunctional amines commonly used as monomers in the manufacture of food contact materials. Amines were analyzed by high-performance-liquid chromatography with diode-array detection (HPLC-DAD) after derivatization with dansyl chloride. The chromatographic analysis and the derivatization conditions were optimized. The proposed method was validated in terms of linearity, limits of detection and repeatabilities. The method showed an excellent sensitivity (LOD≤0.05 μg/mL) and appropriate repeatabilites (RSD (n=7)≤5%)). LC-MS/MS was used as a confirmatory technique. The stability of the amines in five food simulants (distilled water, 3% acetic acid, 10% ethanol, 50% ethanol and olive oil) under the most common testing conditions (10 days at 40 °C) was also studied. Results showed that amines had an acceptable stability in aqueous simulants but in the olive oil a loss of 100% was observed for all analytes. Copyright © 2011. Published by Elsevier B.V.

  6. Triazine-Substituted and Acyl Hydrazones: Experiment and Computation Reveal a Stability Inversion at Low pH.

    PubMed

    Ji, Kun; Lee, Changsuk; Janesko, Benjamin G; Simanek, Eric E

    2015-08-03

    Condensation of a hydrazine-substituted s-triazine with an aldehyde or ketone yields an equivalent to the widely used, acid-labile acyl hydrazone. Hydrolysis of these hydrazones using a formaldehyde trap as monitored using HPLC reveals that triazine-substituted hydrazones are more labile than acetyl hydrazones at pH>5. The reactivity trends mirror that of the corresponding acetyl hydrazones, with hydrolysis rates increasing along the series (aromatic aldehyde

  7. Ultra-High Performance Liquid Chromatography (UHPLC) Method for the Determination of Limonene in Sweet Orange (Citrus sinensis) Oil: Implications for Limonene Stability.

    PubMed

    Bernart, Matthew W

    2015-01-01

    The citrus-derived bioactive monoterpene limonene is an important industrial commodity and fragrance constituent. An RP isocratic elution C18 ultra-HPLC (UHPLC) method using a superficially porous stationary phase and photodiode array (PDA) detector has been developed for determining the limonene content of sweet orange (Citrus sinensis) oil. The method is fast with a cycle time of 1.2 min, linear, precise, accurate, specific, and stability indicating, and it satisfies U.S. Pharmacopeia suitability parameters. The method may be useful in its present form for limonene processing, or modified for research on more polar compounds of the terpenome. A forced-degradation experiment showed that limonene is degraded by heat in hydro-ethanolic solution. PDA detection facilitates classification of minor components of the essential oil, including β-myrcene.

  8. Intracellular zidovudine (ZDV) and ZDV phosphates as measured by a validated combined high-pressure liquid chromatography-radioimmunoassay procedure.

    PubMed Central

    Slusher, J T; Kuwahara, S K; Hamzeh, F M; Lewis, L D; Kornhauser, D M; Lietman, P S

    1992-01-01

    In vitro studies of zidovudine (ZDV) phosphorylation may not accurately reflect the in vivo dose-response relationship, which is crucial to determining the relationship between ZDV exposure, efficacy, and toxicity. However, measurement of ZDV phosphorylated anabolites in peripheral blood mononuclear cells (PBMCs) from ZDV-treated human immunodeficiency virus (HIV)-infected patients would be extremely useful in the more appropriate utilization of ZDV in the treatment of HIV infection. We developed a specific and sensitive combined high-pressure liquid chromatography (HPLC)-radioimmunoassay (RIA) procedure for the determination of ZDV, ZDV-monophosphate, ZDV-diphosphate, and ZDV-triphosphate in PBMCs taken from ZDV-treated HIV-infected patients. ZDV and its anabolites were extracted from washed, Ficoll-Paque-isolated PBMCs and then separated by HPLC using a strong anion-exchange column. The anabolites were then hydrolyzed to ZDV with acid phosphatase. ZDV was then measured by using a modified commercially available RIA protocol. Our method was validated by measuring [3H]ZDV anabolites generated in Molt-4 cells radioisotopically and simultaneously by the combined HPLC-RIA procedure. The ZDV determinations correlated well (r2 = 0.97) over the range of 0.037 to 5.2 pmol (10 to 1,400 pg) per assay tube. Furthermore, we defined the stability of ZDV anabolites during ficoll isolation and the recovery after extraction and cleanup. We then measured intracellular parent ZDV and its phosphorylated anabolites in PBMCs from six ZDV-treated HIV-infected patients (PBMCs were taken 2 h after a 300-mg oral dose). The mean concentrations ( +/- standard deviations) of parent and of mono-, di-, and triphosphates were 0.15 +/- 0.08, 1.4 +/-, 0.082 +/- 0.02, and 0.081 +/- 0.03 pmol/10(6) PBMC, respectively (one pmol/10(6) PBMC represents a concentration of approximately 1 microm). Concurrent serum ZDV concentrations were between 1.3 and 7.1 microm. This method should provide a useful tool for evaluating in vivo pharmacokinetics of ZDV anabolites in PBMCs and possibly other cell types, even at the low doses of ZDV currently administered therapeutically. PMID:1489190

  9. A novel liquid chromatography method using diode-array detector for the determination of oleuropein in dietary supplements.

    PubMed

    Bertolini, Tiziana; Vicentini, Lorenza; Boschetti, Silvia; Andreatta, Paolo; Gatti, Rita

    2016-09-10

    A simple and fast chromatographic method using ultraviolet diode-array detector (UV-DAD) was developed for the automatic high performance liquid chromatography (HPLC) determination of the title of oleuropein in a new dietary supplements in form of effervescent granules. The chromatographic separations were performed on a C18 core-shell column with detection at λ=232nm. The mobile phase consisted of deionized water with 0.1% TFA and acetonitrile under gradient conditions at a flow-rate of 0.8mL/min. Oleuropein and oleuroside present in the raw material were characterized by high performance liquid chromatography-electrospray ionization tandem mass spectrometry (HPLC-ESI-MS/MS). The validation of the analytical procedure has been performed determining the following parameters: specificity, linearity, repeatability, reproducibility, accuracy, limit of quantification (LOQ), stability of the standard and sample solutions. Linear response was observed in fortified placebo solutions (determination coefficient: 0.9998). Intra-day precision (relative standard deviation, RSD) was ≤5.0% for peak area and for retention times (tR) without significant differences between intra- and inter-day data. The limits of quantitation (LOQ) was about 5μg/mL and 9pmol/inject. Oleuropein recovery studies gave good results (99.9%) with a R.S.D. of 0.5%. The speed of analysis and the stability of the solutions with a fluctuation Δ (%) ≤2.0 at room temperature means an undoubted advantage of the method allowing the simultaneous preparation of many samples and consecutive chromatographic analyses by using an autosampler. The developed method is suitable for the quality control of oleuropein in raw material and industrial products. The method can be applied in any analytical laboratory not requiring a sophisticated instrumentation. Copyright © 2016 Elsevier B.V. All rights reserved.

  10. Compatibility of butorphanol with granisetron in 0.9% sodium chloride injection packaged in glass bottles or polyolefin bags.

    PubMed

    Chen, Fu-Chao; Xiong, Hui; Liu, Hui-Min; Fang, Bao-Xia; Li, Peng

    2015-08-15

    The stability of admixtures containing butorphanol and granisetron in polyolefin bags and glass bottles stored at 4 and 25 °C was studied. Commercial solutions of butorphanol tartrate and granisetron hydrochloride were combined and further diluted with 0.9% sodium chloride injection to final concentrations of butorphanol tartrate 0.08 mg/mL and granisetron 0.03 or 0.06 mg/mL; the resulting mixtures were packaged in polyolefin bags and glass bottles. The admixtures were assessed for periods of up to 48 hours after storage at 25 °C without protection from room light and up to 14 days at 4 °C with protection from room light. The chemical stability of the admixtures was evaluated by a validated high-performance liquid chromatography (HPLC) method and by measurement of pH values. Solution appearance and color were assessed by observing the samples against room light and dark backgrounds. HPLC analysis demonstrated that the percentages of the initial concentrations of butorphanol and granisetron in the various solutions remained above 97% during the testing period. No changes in color or turbidity were observed in any of the prepared solutions. Throughout this period, pH values remained stable. Admixtures of butorphanol tartrate 0.08 mg/mL and granisetron 0.03 or 0.06 mg/mL in 0.9% sodium chloride injection in polyolefin bags or glass bottles remained stable for 48 hours when stored at 25 °C exposed to room light and for 14 days when stored at 4 °C protected from room light. Copyright © 2015 by the American Society of Health-System Pharmacists, Inc. All rights reserved.

  11. A simple method for plasma total vitamin C analysis suitable for routine clinical laboratory use.

    PubMed

    Robitaille, Line; Hoffer, L John

    2016-04-21

    In-hospital hypovitaminosis C is highly prevalent but almost completely unrecognized. Medical awareness of this potentially important disorder is hindered by the inability of most hospital laboratories to determine plasma vitamin C concentrations. The availability of a simple, reliable method for analyzing plasma vitamin C could increase opportunities for routine plasma vitamin C analysis in clinical medicine. Plasma vitamin C can be analyzed by high performance liquid chromatography (HPLC) with electrochemical (EC) or ultraviolet (UV) light detection. We modified existing UV-HPLC methods for plasma total vitamin C analysis (the sum of ascorbic and dehydroascorbic acid) to develop a simple, constant-low-pH sample reduction procedure followed by isocratic reverse-phase HPLC separation using a purely aqueous low-pH non-buffered mobile phase. Although EC-HPLC is widely recommended over UV-HPLC for plasma total vitamin C analysis, the two methods have never been directly compared. We formally compared the simplified UV-HPLC method with EC-HPLC in 80 consecutive clinical samples. The simplified UV-HPLC method was less expensive, easier to set up, required fewer reagents and no pH adjustments, and demonstrated greater sample stability than many existing methods for plasma vitamin C analysis. When compared with the gold-standard EC-HPLC method in 80 consecutive clinical samples exhibiting a wide range of plasma vitamin C concentrations, it performed equivalently. The easy set up, simplicity and sensitivity of the plasma vitamin C analysis method described here could make it practical in a normally equipped hospital laboratory. Unlike any prior UV-HPLC method for plasma total vitamin C analysis, it was rigorously compared with the gold-standard EC-HPLC method and performed equivalently. Adoption of this method could increase the availability of plasma vitamin C analysis in clinical medicine.

  12. [Simultaneous determination of 9 ultraviolet stabilizers in food plastic packaging materials by solid phase extraction-high performance liquid chromatography].

    PubMed

    Zhang, Juzhou; Li, Jing; Shao, Dongliang; Yao, Bangben; Jiang, Junshu

    2012-02-01

    An effective high performance liquid chromatographic (HPLC) method has been developed for the simultaneous determination of 9 ultraviolet stabilizers in food plastic packaging materials. The food packaging samples were firstly extracted by methanol-ethyl acetate, and then purified by a C18 solid-phase extraction (SPE) column. The target compounds were separated on a ZORBAX SB-C18 column (250 mm x 4.6 mm, 5 microm) in gradient elution mode using methanol and water as mobile phases. The detection wavelength was at 310 nm. The linear plots of the nine ultraviolet stabilizers were obtained between 0.2 and 10 mg/L, with the correlation coefficients of above 0. 999 for the nine ultraviolet stabilizers. The limits of detection for this method were in the range from 0.05 to 0.1 mg/L. The recoveries spiked in commercial food plastic packaging materials were in the range of 70.2% - 89.0% with the relative standard deviations of 0.4% - 4.5%. The results indicated that the method is simple, accurate, and suitable for the simultaneous determination of the nine ultraviolet stabilizers in food plastic packaging materials.

  13. IFCC approved HPLC reference measurement procedure for the alcohol consumption biomarker carbohydrate-deficient transferrin (CDT): Its validation and use.

    PubMed

    Schellenberg, François; Wielders, Jos; Anton, Raymond; Bianchi, Vincenza; Deenmamode, Jean; Weykamp, Cas; Whitfield, John; Jeppsson, Jan-Olof; Helander, Anders

    2017-02-01

    Carbohydrate-deficient transferrin (CDT) is used as a biomarker of sustained high alcohol consumption. The currently available measurement procedures for CDT are based on various analytical techniques (HPLC, capillary electrophoresis, nephelometry), some differing in the definition of the analyte and using different reference intervals and cut-off values. The Working Group on Standardization of CDT (WG-CDT), initiated by the International Federation of Clinical Chemistry and Laboratory Medicine (IFCC), has validated an HPLC candidate reference measurement procedure (cRMP) for CDT (% disialotransferrin to total transferrin based on peak areas), demonstrating that it is suitable as a reference measurement procedure (RMP) for CDT. Presented is a detailed description of the cRMP and its calibration. Practical aspects on how to treat genetic variant and so-called di-tri bridge samples are described. Results of method performance characteristics, as demanded by ISO 15189 and ISO 15193, are given, as well as the reference interval and measurement uncertainty and how to deal with that in routine use. The correlation of the cRMP with commercial CDT procedures and the performance of the cRMP in a network of laboratories are also presented. The performance of the CDT cRMP in combination with previously developed commutable calibrators allows for standardization of the currently available commercial measurement procedures for CDT. The cRMP has recently been approved by the IFCC and will be from now on be known as the IFCC-RMP for CDT, while CDT results standardized according to this RMP should be indicated as CDT IFCC . Copyright © 2016 Elsevier B.V. All rights reserved.

  14. Topiramate: A Review of Analytical Approaches for the Drug Substance, Its Impurities and Pharmaceutical Formulations.

    PubMed

    Pinto, Eduardo Costa; Dolzan, Maressa Danielli; Cabral, Lucio Mendes; Armstrong, Daniel W; de Sousa, Valéria Pereira

    2016-02-01

    An important step during the development of high-performance liquid chromatography (HPLC) methods for quantitative analysis of drugs is choosing the appropriate detector. High sensitivity, reproducibility, stability, wide linear range, compatibility with gradient elution, non-destructive detection of the analyte and response unaffected by changes in the temperature/flow are some of the ideal characteristics of a universal HPLC detector. Topiramate is an anticonvulsant drug mainly used for the treatment of different types of seizures and prophylactic treatment of migraine. Different analytical approaches to quantify topiramate by HPLC have been described because of the lack of chromophoric moieties on its structure, such as derivatization with fluorescent moieties and UV-absorbing moieties, conductivity detection, evaporative light scattering detection, refractive index detection, chemiluminescent nitrogen detection and MS detection. Some methods for the determination of topiramate by capillary electrophoresis and gas chromatography have also been published. This systematic review provides a description of the main analytical methods presented in the literature to analyze topiramate in the drug substance and in pharmaceutical formulations. Each of these methods is briefly discussed, especially considering the detector used with HPLC. In addition, this article presents a review of the data available regarding topiramate stability, degradation products and impurities. © The Author 2015. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.

  15. Stability of Colistin and Colistin Methanesulfonate in Aqueous Media and Plasma as Determined by High-Performance Liquid Chromatography

    PubMed Central

    Li, Jian; Milne, Robert W.; Nation, Roger L.; Turnidge, John D.; Coulthard, Kingsley

    2003-01-01

    The stabilities of colistin and colistin methanesulfonate (CMS) in different aqueous media were studied by specific high-performance liquid chromatography (HPLC) methods. Colistin was stable in water at 4 and 37°C for up to 60 days and 120 h, respectively. However, degradation was observed when colistin was stored in isotonic phosphate buffer (0.067 M, pH 7.4) and human plasma at 37°C. The stability of CMS from three different sources in water was explored by strong-anion-exchange (SAX) HPLC for CMS and by measuring the concentrations of colistin formed from the hydrolysis of CMS. The peaks of CMS in SAX HPLC disappeared almost completely after 12 h at 37°C, but appeared to remain intact for up to 2 days at 4°C. Over the same period, there was no formation of colistin at 4°C. In water, phosphate buffer, and plasma, there was rapid formation of colistin within 24 to 48 h at 37°C from the three sources of CMS. The hydrolysis products were assumed to be a complex mixture of many different sulfomethyl derivatives, including colistin. The stability of a fourth source of CMS in Mueller-Hinton broth examined during 30 min at 37°C revealed no formation of colistin. Along with previous microbiological studies, this suggested that different sulfomethyl CMSs possess intrinsic antibacterial activity. These results will be helpful for understanding the pharmacokinetics and pharmacodynamics of colistin and CMS in humans and animals. PMID:12654671

  16. PHYSICAL AND CHEMICAL STABILITY ANALYSIS OF COSMETIC MULTI- PLE EMULSIONS LOADED WITH ASCORBYL PALMITATE AND SODIUM ASCORBYL PHOSPHATE SALTS.

    PubMed

    Khan, Hira; Akhtar, Naveed; Ali, Atif; Khan, Haji M Shoaib; Sohail, Muhammad; Naeem, Muhammad; Nawaz, Zarqa

    2016-09-01

    Stability of hydrophilic and lipophilic vitamin C derivatives for quenching synergistic antioxidant activities and to treat oxidative related diseases is a major issue. This study was aimed to encapsulate hydrophilic and lipophilic vitamin C derivatives (ascorbyl palmitate and sodium ascorbyl phosphate) as functional ingredients in a newly formulated multiple emulsion of the W//W type to attain the synergistic antioxidant effects and the resultant system's long term physical and chemical stability. Several multiple emulsions using the same concentration of emulsifiers but different concentrations of ascorbyl palmitate and sodium ascorbyl phosphate were developed. Three finally selected multiple emulsions (ME₁, ME₂ and ME₃) were evaluated for physical stability in terms of rheology, microscopy, conductivity, pH, and organoleptic characteristics under different storage conditions for 3 months. Chemical stability was determined by HPLC on Sykam GmbH HPLC system (Germany), equipped with a variable UV detector. Results showed that at accelerated storage conditions all the three multiple emulsions had shear thinning behavior of varying shear stress with no influence of location of functional ingredients in a carrier system. Conductivity values increased and pH values remained within the skin pH range for 3 months. Microscopic analysis showed an increase in globule size with the passage of time, especially at higher temperatures while decreased at low temperatures. Centrifugation test did not cause phase separation till the 45th day, but little effects after 2 months. Chemical stability analysis by HPLC at the end of 3 months showed that ascorbyl palmitate and sodium ascorbyl phosphate were almost stable in all multiple emulsions with no influence of their location in a carrier system. Multiple emulsions were found a stable carrier for hydrophilic and lipophilic vitamin C derivatives to enhance their desired effects. Considering that many topical formulations contain simple vitamin C it is suggested that present study may contribute to the development of more stable formulations with a combination of vitamin C derivatives to enhance their cosmetic benefits.

  17. Steroids

    NASA Astrophysics Data System (ADS)

    Frey, Felix J.; Frey, Brigitte M.; Benet, Leslie Z.

    If a radioimmunoassay, a protein binding method, or a colorimetric assay for the assessment of a steroid level is replaced by high performance liquid chromatography (HPLC), the cost for the determination of a steroid level increases at least initially because one must acquire the new HPLC equipment. Therefore, if an older method provides the same results as the new, "advanced" HPLC method, the only advantage resulting from the introduction of a high performance chromatographic assay is that gained by the manufacturer in terms of greater sales. Thus, justification for the assessment of steroids by HPLC is only obtained if the quality and/or quantity of information gained is significantly increased as compared to that provided by the conventional methods. But this evidential relation, that more and better information justifies a higher price in any case, is no longer true in health care, with the birth some years ago of the categoric imperative for the reduction of costs in the medical sector. That is, each new technology introduced for health maintenance should demonstrate at least a stabilizing impact on total medical expenditures. Therefore, after reviewing the presently available HPLC methods for the clinically important steroids, we will consider whether HPLC analyses for these steroids can be recommended without violating this vox populi.

  18. Quantitative Clinical Diagnostic Analysis of Acetone in Human Blood by HPLC: A Metabolomic Search for Acetone as Indicator

    PubMed Central

    Akgul Kalkan, Esin; Sahiner, Mehtap; Ulker Cakir, Dilek; Alpaslan, Duygu; Yilmaz, Selehattin

    2016-01-01

    Using high-performance liquid chromatography (HPLC) and 2,4-dinitrophenylhydrazine (2,4-DNPH) as a derivatizing reagent, an analytical method was developed for the quantitative determination of acetone in human blood. The determination was carried out at 365 nm using an ultraviolet-visible (UV-Vis) diode array detector (DAD). For acetone as its 2,4-dinitrophenylhydrazone derivative, a good separation was achieved with a ThermoAcclaim C18 column (15 cm × 4.6 mm × 3 μm) at retention time (t R) 12.10 min and flowrate of 1 mL min−1 using a (methanol/acetonitrile) water elution gradient. The methodology is simple, rapid, sensitive, and of low cost, exhibits good reproducibility, and allows the analysis of acetone in biological fluids. A calibration curve was obtained for acetone using its standard solutions in acetonitrile. Quantitative analysis of acetone in human blood was successfully carried out using this calibration graph. The applied method was validated in parameters of linearity, limit of detection and quantification, accuracy, and precision. We also present acetone as a useful tool for the HPLC-based metabolomic investigation of endogenous metabolism and quantitative clinical diagnostic analysis. PMID:27298750

  19. Compatibility and stability of tramadol and dexamethasone in solution and its use in terminally ill patients.

    PubMed

    Negro, S; Salama, A; Sánchez, Y; Azuara, M L; Barcia, E

    2007-10-01

    Delivery of drug admixtures by continuous subcutaneous infusion is common practice in palliative medicine, but analytical confirmation of their compatibility and stability is not always available. To study the compatibility and stability of tramadol hydrochloride and dexamethasone sodium phosphate combined in solution and to report on its use in terminally ill patients. Twelve different solutions containing tramadol hydrochloride (8.33-33.33 mg/mL) and dexamethasone sodium phosphate (0.33-3.33 mg/mL) were prepared in saline and stored in polypropylene syringes for 5 days (25 degrees C). Analysis was performed on days 1, 3 and 5 days with simultaneous determination by HPLC. pH was measured at 0 and 5 days. Clinical performance was assessed retrospectively in six terminal-ill oncology patients. Maximum losses of 7% and 6% were observed for tramadol and dexamethasone. Pain was completely controlled in four patients. Local tolerance resulted in haematoma in three patients, which resolved by switching to a butterfly insertion site. Tramadol hydrochloride (100-400 mg/day) and dexamethasone sodium phosphate (4-40 mg/day) are stable for at least 5 days when combined in saline and stored at 25 degrees C. These results are only valid for the type of syringes and the specific commercial preparations tested.

  20. Development and validation of a RP-HPLC method for the quantitation of tofacitinib in rat plasma and its application to a pharmacokinetic study.

    PubMed

    S, Vijay Kumar; Dhiman, Vinay; Giri, Kalpesh Kumar; Sharma, Kuldeep; Zainuddin, Mohd; Mullangi, Ramesh

    2015-09-01

    A novel, simple, specific, sensitive and reproducible high-performance liquid chromatography (HPLC) assay method has been developed and validated for the estimation of tofacitinib in rat plasma. The bioanalytical procedure involves extraction of tofacitinib and itraconazole (internal standard, IS) from rat plasma with a simple liquid-liquid extraction process. The chromatographic analysis was performed on a Waters Alliance system using a gradient mobile phase conditions at a flow rate of 1.0 mL/min and C18 column maintained at 40 ± 1 °C. The eluate was monitored using an UV detector set at 287 nm. Tofacitinib and IS eluted at 6.5 and 8.3 min, respectively and the total run time was 10 min. Method validation was performed as per US Food and Drug Administration guidelines and the results met the acceptance criteria. The calibration curve was linear over a concentration range of 182-5035 ng/mL (r(2) = 0.995). The intra- and inter-day precisions were in the range of 1.41-11.2 and 3.66-8.81%, respectively, in rat plasma. The validated HPLC method was successfully applied to a pharmacokinetic study in rats. Copyright © 2015 John Wiley & Sons, Ltd.

  1. Validation of a RP-HPLC-DAD Method for Chamomile (Matricaria recutita) Preparations and Assessment of the Marker, Apigenin-7-glucoside, Safety and Anti-Inflammatory Effect

    PubMed Central

    Miguel, Felipe Galeti; Spinola, Nathália Favaretto; Ribeiro, Diego Luis; Barcelos, Gustavo Rafael Mazzaron; Antunes, Lusânia Maria Greggi; Hori, Juliana Issa; Marquele-Oliveira, Franciane; Rocha, Bruno Alves; Berretta, Andresa Aparecida

    2015-01-01

    Chamomile is a medicinal plant, which presents several biological effects, especially the anti-inflammatory effect. One of the compounds related to this effect is apigenin, a flavonoid that is mostly found in its glycosylated form, apigenin-7-glucoside (APG), in natural sources. However, the affectivity and safety of this glycoside have not been well explored for topical application. In this context, the aim of this work was to develop and validate a reversed-phase high-performance liquid chromatography (RP-HPLC-DAD) method to quantify APG in chamomile preparations. Additionally, the safety and the anti-inflammatory potential of this flavonoid were verified. The RP-HPLC-DAD method was developed and validated with linearity at 24.0–36.0 μg/mL range (r = 0.9994). Intra- and interday precision (RSD) were 0.27–2.66% and accuracy was 98.27–101.21%. The validated method was applied in the analysis of chamomile flower heads, glycolic extract, and Kamillen cream, supporting the method application in the quality control of chamomile preparations. Furthermore, the APG safety was assessed by MTT cytotoxicity assay and mutagenic protocols and the anti-inflammatory activity was confirmed by a diminished TNF-α production showed by mice macrophages treated with APG following LPS treatment. PMID:26421053

  2. Therapeutic drug monitoring of seven psychotropic drugs and four metabolites in human plasma by HPLC-MS.

    PubMed

    Choong, Eva; Rudaz, Serge; Kottelat, Astrid; Guillarme, Davy; Veuthey, Jean-Luc; Eap, Chin B

    2009-12-05

    A simple and sensitive LC-MS method was developed and validated for the simultaneous quantification of aripiprazole (ARI), atomoxetine (ATO), duloxetine (DUL), clozapine (CLO), olanzapine (OLA), sertindole (STN), venlafaxine (VEN) and their active metabolites dehydroaripiprazole (DARI), norclozapine (NCLO), dehydrosertindole (DSTN) and O-desmethylvenlafaxine (OVEN) in human plasma. The above mentioned compounds and the internal standard (remoxipride) were extracted from 0.5 mL plasma by solid-phase extraction (mix mode support). The analytical separation was carried out on a reverse phase liquid chromatography at basic pH (pH 8.1) in gradient mode. All analytes were monitored by MS detection in the single ion monitoring mode and the method was validated covering the corresponding therapeutic range: 2-200 ng/mL for DUL, OLA, and STN, 4-200 ng/mL for DSTN, 5-1000 ng/mL for ARI, DARI and finally 2-1000 ng/mL for ATO, CLO, NCLO, VEN, OVEN. For all investigated compounds, good performance in terms of recoveries, selectivity, stability, repeatability, intermediate precision, trueness and accuracy, was obtained. Real patient plasma samples were then successfully analysed.

  3. Quality by design (QbD) based development and validation of an HPLC method for amiodarone hydrochloride and its impurities in the drug substance.

    PubMed

    Karmarkar, S; Yang, X; Garber, R; Szajkovics, A; Koberda, M

    2014-11-01

    The USP monograph describes an HPLC method for seven impurities in the amiodarone drug substance using a L1 column, 4.6mm×150mm, 5μm packing (PF listed ODS2 GL-Science, Inertsil column) at 30°C with detection at 240nm. The standard contains 0.01mg/mL of amiodarone, and USP specified impurities D and E with a resolution requirement of NLT 3.5 between peaks D and E. Impurities in a 5mg/mL sample are quantitated against the standard. Impurity A peak elutes just before peak D. We observed two problems with the method; the column lot-to-lot variability resulted in unresolved A, D, and E peaks, and peak D in the sample preparation eluted much later than that in the standard solution. Therefore, optimization experiments were conducted on the USP method following the QbD approach with Fusion AE™ software (S-Matrix Corporation). The resulting optimized conditions were within the allowable changes per USP 〈621〉. Lot-to-lot variability was negligible with the Atlantis T3 (Waters Corporation) L1 column. Peak D retention time remained constant from standard to sample. The optimized method was validated in terms of accuracy, precision, linearity, range, LOQ/LOD, specificity, robustness, equivalency to the USP method, and solution stability. The QbD based development helped in generating a design space and operating space with knowledge of all method performance characteristics and limitations and successful method robustness within the operating space. Copyright © 2014 Elsevier B.V. All rights reserved.

  4. The quantitative determination of cilostazol and its four metabolites in human liver microsomal incubation mixtures by high-performance liquid chromatography.

    PubMed

    Tata, P N; Fu, C H; Browder, N J; Chow, P C; Bramer, S L

    1998-11-01

    A high-performance liquid chromatography-ultraviolet (HPLC-UV) method for the quantitation of cilostazol and four of its principal metabolites (i.e. OPC-13015, OPC-13213, OPC-13217 and OPC-13326) in human liver microsomal solutions was developed and validated. Cilostazol, its metabolites, and the internal standard (OPC-3930), were analyzed by protein precipitation followed by reverse-phase HPLC separation on a TSK-Gel ODS-80TM (150 x 4.6 mm, 5 microm) column and a Cosmil C-18 column (150 x 4.6 mm, 5 microm) in tandem and UV detection at 254 nm. An 80 min gradient elution of mobile phase acetonitrile in acetate buffer (pH = 6.50) was used to obtain quality chromatography and peak resolution. All the analytes were separated from each other, with the resolution being 2.43-17.59. The components of liver microsomal incubation mixture and five metabolic inhibitor probes (quinidine sulfate, diethyl dithiocarbamate (DEDTC), omeprazole, ketoconazole and furafylline) did not interfere with this analytical method. The LOQ was 1000 ng ml(-1) for cilostazol and 100 ng ml(-1) for each of the metabolites. This method has been validated for linear ranges of 100-4000 ng ml(-1) for OPC-13213, OPC-13217 and OPC-13326; 100-2000 ng ml(-1) for OPC-13015; and 1000-20000 ng ml(-1) for cilostazol. The percent relative recovery of this method was established to be 81.2-101.0% for analytes, with the precision (% coefficient of variation (CV)) being 2.8-7.7%. The autosampler stability of the analytes was evaluated and it was found that all analytes were stable at room temperature for a period of at least 17 h. This assay has been shown to be precise, accurate and reproducible.

  5. Development and validation of an RP-HPLC method for quantification of cinnamic acid derivatives and kaurane-type diterpenes in Mikania laevigata and Mikania glomerata.

    PubMed

    Bertolucci, Suzan Kelly; Pereira, Ana Bárbara; Pinto, José Eduardo; de Aquino Ribeiro, José Antônio; de Oliveira, Alaíde Braga; Braga, Fernão Castro

    2009-02-01

    MIKANIA GLOMERATA and MIKANIA LAEVIGATA (Asteraceae) are medicinal plants popularly named 'guaco' in Brazil. The leaves of both species are used to treat respiratory diseases, with coumarin (CO) and kaurane-type diterpenes being regarded as the bioactive constituents. A new and simple RP-HPLC method was developed and validated for the simultaneous quantification of CO, O-coumaric (OC), benzoylgrandifloric (BA), cinnamoylgrandifloric (CA) and kaurenoic (KA) acids in the species. Optimal separation was achieved with an alternating gradient elution of methanol and acetonitrile and detection was carried out by DAD at three different wavelengths: 210 nm for CO, OC, KA; 230 nm for BA; and 270 nm for CA. The extracts showed good stability during 42 hours under normal laboratory conditions (temperature of 23 +/- 2 degrees C). The standard curves were linear over the range 0.5 - 5.0 microg (CO), 0.25 - 4.0 microg (OC), 1.0 - 8.0 microg (BA), 0.5 - 3.0 microg (CA) and 0.8 - 12.0 microg (KA), with R(2) > 0.999 for all compounds. The method showed good precision for intra-day (RSD < 4.6 %) and inter-day assays (RSD < 4.4 %). The recovery was between 99.9 and 105.3 %, except for CO and OC in M. glomerata (73.2 - 91.6 % and 86.3 - 117.4 %, respectively). The limits of quantification and detection were in the range of 0.025 - 0.800 microg and 0.007 - 0.240 microg. The method was tested for new and old columns, temperature variation (26 and 28 degrees C) and by different operators in the same laboratory. The method was successfully applied to samples of both species.

  6. Development and validation of a general derivatization HPLC method for the trace analysis of acyl chlorides in lipophilic drug substances.

    PubMed

    Zheng, Xiangyuan; Luo, Lan; Zhou, Jie; Ruan, Xiaoling; Liu, Wenyuan; Zheng, Feng

    2017-06-05

    Acyl chlorides are important acylating agents in the synthesis of active pharmaceutical ingredients. Determining the residual acyl chlorides in drug substances is a challenge due to their high reactivity and the matrix interferences from drug substances and their related impurities. This paper describes a general derivatization HPLC method for the determination of aromatic and aliphatic acyl chlorides in lipophilic drug substances. Since most drug substances have weak absorptions in the visible range (above 380nm), the nitro-substituted anilines and nitro-substituted phenylhydrazines were selected as the derivatization reagents due to their weak basicity and red-shift of UV absorption spectra. The maximum wavelength and absorption intensity of nitro-substituted anilines decreased after derivatization with acyl chlorides, whereas the derivatization products of nitro-substituted phenylhydrazines showed the slight increases of maximum wavelength and absorbance intensity. Hence, 2-nitrophenylhydrazine was selected as the suitable derivatization reagent because the derivatives have the maximum UV wavelength absorbance at 395nm, which could largely minimize the matrix interferences. The optimization of the concentration of 2-nitrophenylhydrazine is important for the sensitivity and stability of derivatives. Other reaction conditions including reaction temperature, time and the influence of three competitive solvents (water, methanol and ethanol) on the reaction efficiency were also studied. After derivatization with 100μgmL -1 2-nitrophenylhydrazine at room temperature for 30min, the method was validated for high specificity and sensitivity with the detection limits in the range of 0.01-0.03μgmL -1 . The proposed method was applied as a generic method to determine the residual acyl chlorides in lipophilic drug substances. Copyright © 2017 Elsevier B.V. All rights reserved.

  7. Reversed phase HPLC for strontium ranelate: Method development and validation applying experimental design.

    PubMed

    Kovács, Béla; Kántor, Lajos Kristóf; Croitoru, Mircea Dumitru; Kelemen, Éva Katalin; Obreja, Mona; Nagy, Előd Ernő; Székely-Szentmiklósi, Blanka; Gyéresi, Árpád

    2018-06-01

    A reverse-phase HPLC (RP-HPLC) method was developed for strontium ranelate using a full factorial, screening experimental design. The analytical procedure was validated according to international guidelines for linearity, selectivity, sensitivity, accuracy and precision. A separate experimental design was used to demonstrate the robustness of the method. Strontium ranelate was eluted at 4.4 minutes and showed no interference with the excipients used in the formulation, at 321 nm. The method is linear in the range of 20-320 μg mL-1 (R2 = 0.99998). Recovery, tested in the range of 40-120 μg mL-1, was found to be 96.1-102.1 %. Intra-day and intermediate precision RSDs ranged from 1.0-1.4 and 1.2-1.4 %, resp. The limit of detection and limit of quantitation were 0.06 and 0.20 μg mL-1, resp. The proposed technique is fast, cost-effective, reliable and reproducible, and is proposed for the routine analysis of strontium ranelate.

  8. Structural elucidation of potential impurities in Azilsartan bulk drug by HPLC.

    PubMed

    Zhou, Wentao; Zhou, Yuxia; Sun, Lili; Zou, Qiaogen; Wei, Ping; Ouyang, Pingkai

    2014-01-01

    During the synthesis of Azilsartan (AZS), it was speculated that 15 potential impurities would arise. This study investigated the possible mechanism for the formation of 14 of them, and their structures were characterized and confirmed by IR, NMR, and MS techniques. In addition, an efficient chromatographic method was developed to separate and quantify these impurities, using an Inertsil ODS-3 column (250 x 4.6 mm, 5 pm) in gradient mode with a mixture of acetonitrile and the potassium dihydrogen orthophosphate buffer (10 mM, pH adjusted to 3.0 with phosphoric acid). The HPLC method was validated for specificity, precision, accuracy, and sensitivity. LOQ of impurities were in the range of 1.04-2.20 ng. Correlation coefficient values of linearity were >0.9996 for AZS and its impurities. The mean recoveries of all impurities in AZS were between 93.0 and 109.7%. Thus, the validated HPLC method is suitable for the separation and quantification of all potential impurities in AZS.

  9. Influence of storage conditions on the stability of monomeric anthocyanins studied by reversed-phase high-performance liquid chromatography.

    PubMed

    Morais, Helena; Ramos, Cristina; Forgács, Esther; Cserháti, Tibor; Oliviera, José

    2002-04-25

    The effect of light, storage time and temperature on the decomposition rate of monomeric anthocyanin pigments extracted from skins of grape (Vitis vinifera var. Red globe) was determined by reversed-phase high-performance liquid chromatography (RP-HPLC). The impact of various storage conditions on the pigment stability was assessed by stepwise regression analysis. RP-HPLC separated well the five anthocyanins identified and proved the presence of other unidentified pigments at lower concentrations. Stepwise regression analysis confirmed that the overall decomposition rate of monomeric anthocyanins, peonidin-3-glucoside and malvidin-3-glucoside significantly depended on the time and temperature of storage, the effect of storage time being the most important. The presence or absence of light exerted a negligible impact on the decomposition rate.

  10. Development and validation of an HPLC-DAD method for simultaneous determination of cocaine, benzoic acid, benzoylecgonine and the main adulterants found in products based on cocaine.

    PubMed

    Floriani, Gisele; Gasparetto, João Cleverson; Pontarolo, Roberto; Gonçalves, Alan Guilherme

    2014-02-01

    Here, an HPLC-DAD method was developed and validated for simultaneous determination of cocaine, two cocaine degradation products (benzoylecgonine and benzoic acid), and the main adulterants found in products based on cocaine (caffeine, lidocaine, phenacetin, benzocaine and diltiazem). The new method was developed and validated using an XBridge C18 4.6mm×250mm, 5μm particle size column maintained at 60°C. The mobile phase consisted of a gradient of acetonitrile and ammonium formate 0.05M - pH 3.1, eluted at 1.0mL/min. The volume of injection was 10μL and the DAD detector was set at 274nm. Method validation assays demonstrated suitable sensitivity, selectivity, linearity, precision and accuracy. For selectivity assay, a MS detection system could be directly adapted to the method without the need of any change in the chromatographic conditions. The robustness study indicated that the flow rate, temperature and pH of the mobile phase are critical parameters and should not be changed considering the conditions herein determined. The new method was then successfully applied for determining cocaine, benzoylecgonine, benzoic acid, caffeine, lidocaine, phenacetin, benzocaine and diltiazem in 115 samples, seized in Brazil (2007-2012), which consisted of cocaine paste, cocaine base and salt cocaine samples. This study revealed cocaine contents that ranged from undetectable to 97.2%, with 97 samples presenting at least one of the degradation products or adulterants here evaluated. All of the studied degradation products and adulterants were observed among the seized samples, justifying the application of the method, which can be used as a screening and quantification tool in forensic analysis. Copyright © 2013 Elsevier Ireland Ltd. All rights reserved.

  11. Analysis of aldehydes in human exhaled breath condensates by in-tube SPME-HPLC.

    PubMed

    Wang, ShuLing; Hu, Sheng; Xu, Hui

    2015-11-05

    In this paper, polypyrrole/graphene (PPy/G) composite coating was prepared by a facile electrochemical polymerization strategy on the inner surface of a stainless steel (SS) tube. Based on the coating tube, a novel online in-tube solid-phase microextraction -high performance liquid chromatography (IT-SPME-HPLC) was developed and applied for the extraction of aldehydes in the human exhaled breath condensates (EBC). The hybrid PPy/G nanocomposite exhibits remarkable chemical and mechanical stability, high selectivity, and satisfactory extraction performance toward aldehyde compounds. Moreover, the proposed online IT-SPME-HPLC method possesses numerous superiorities, such as time and cost saving, process simplicity, high precision and sensitivity. Some parameters related to extraction efficiency were optimized systematically. Under the optimal conditions, the recoveries of the aldehyde compounds at three spiked concentration levels varied in the range of 85%-117%. Good linearity was obtained with excellent correlation coefficients (R(2)) being larger than 0.994. The relative standard deviations (n = 5) of the method ranged from 1.8% to 11.3% and the limits of detection were between 2.3 and 3.3 nmol L(-1). The successful application of the proposed method in human EBC indicated that it is a promising approach for the determination of trace aldehyde metabolites in complex EBC samples. Copyright © 2015 Elsevier B.V. All rights reserved.

  12. Validation of a new point-of-care assay for determination of β-carotene concentration in bovine whole blood and plasma.

    PubMed

    Raila, Jens; Enjalbert, Francis; Mothes, Ralf; Hurtienne, Andrea; Schweigert, Florian J

    2012-03-01

    β-Carotene is an important precursor of vitamin A, and is associated with bovine fertility. β-Carotene concentrations in plasma are used to optimize β-carotene supplementation in cattle, but measurement requires specialized equipment to separate plasma and extract and measure β-carotene, either using spectrophotometry or high performance liquid chromatography (HPLC). The objective of this study was to validate a new 2-step point-of-care (POC) assay for measuring β-carotene in whole blood and plasma. β-carotene concentrations in plasma from 166 cows were measured using HPLC and compared with results obtained using a POC assay, the iCheck-iEx-Carotene test kit. Whole blood samples from 23 of these cattle were also evaluated using the POC assay and compared with HPLC-plasma results from the same 23 animals. The POC assay includes an extraction vial (iEx Carotene) and hand-held photometer (iCheck Carotene). Concentrations of β-carotene in plasma measured using the POC assay ranged from 0.40 to 15.84 mg/L (n = 166). No differences were observed between methods for assay of plasma (mean ± SD; n = 166): HPLC-plasma 4.23 ± 2.35 mg/L; POC-plasma 4.49 ± 2.36 mg/L. Similar good agreement was found when plasma analyzed using HPLC was compared with whole blood analyzed using the POC system (n = 23): HPLC-plasma 3.46 ± 2.12 mg/L; POC-whole blood 3.67 ± 2.29 mg/L. Concentrations of β-carotene can be measured in blood and plasma from cattle easily and rapidly using a POC assay, and results are comparable to those obtained by the highly sophisticated HPLC method. Immediate feedback regarding β-carotene deficiency facilitates rapid and appropriate optimization of β-carotene supplementation in feed. © 2012 American Society for Veterinary Clinical Pathology.

  13. Extraction, stability, and separation of betalains from Opuntia joconostle cv. using response surface methodology.

    PubMed

    Sanchez-Gonzalez, Noe; Jaime-Fonseca, Monica R; San Martin-Martinez, Eduardo; Zepeda, L Gerardo

    2013-12-11

    Betalains were extracted and analyzed from Opuntia joconostle (the prickly pear known as xoconostle in Mexico). For the extraction, two solvent systems were used, methanol/water and ethanol/water. A three-variable Box-Behnken statistical design was used for extraction: solvent concentration (0-80%, v/v), temperature (5-30 °C), and treatment time (10-30 min). The extraction and stability of betalains from xoconostle were studied using response surface methodology (RSM). Techniques such as UV-vis, column chromatography, and HPLC were employed for the separation and analysis of the main pigments present in the extracts. Maximum pigment concentration (92 mg/100 g of fruit) was obtained at a temperature of 15 °C and a time of 10 min for methanol/water (20:80), whereas maximum stability of the pigment was observed at pH 5 and a temperature of 25 °C. HPLC chromatograms showed the main betalains of the xoconostle characterized were betalain, betanidin, and isobetalain.

  14. Determination of some phenolic compounds in red wine by RP-HPLC: method development and validation.

    PubMed

    Burin, Vívian Maria; Arcari, Stefany Grützmann; Costa, Léa Luzia Freitas; Bordignon-Luiz, Marilde T

    2011-09-01

    A methodology employing reversed-phase high-performance liquid chromatography (RP-HPLC) was developed and validated for simultaneous determination of five phenolic compounds in red wine. The chromatographic separation was carried out in a C(18) column with water acidify with acetic acid (pH 2.6) (solvent A) and 20% solvent A and 80% acetonitrile (solvent B) as the mobile phase. The validation parameters included: selectivity, linearity, range, limits of detection and quantitation, precision and accuracy, using an internal standard. All calibration curves were linear (R(2) > 0.999) within the range, and good precision (RSD < 2.6%) and recovery (80-120%) was obtained for all compounds. This method was applied to quantify phenolics in red wine samples from Santa Catarina State, Brazil, and good separation peaks for phenolic compounds in these wines were observed.

  15. Structural Characteristics of the Alpha-Synuclein Oligomers Stabilized By the Flavonoid Baicalein

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Hong, D.-P.; Fink, A.L.; Uversky, V.N.

    The flavonoid baicalein inhibits fibrillation of alpha-synuclein, which is a major component of Lewy bodies in Parkinson's disease. It has been known that baicalein induces the formation of alpha-synuclein oligomers and consequently prevents their fibrillation. In order to evaluate the structural properties of baicalein-stabilized oligomers, we purified oligomer species by HPLC and examined their stability and structure by CD, Fourier transform infrared spectroscopy, size exclusion chromatography HPLC, small-angle X-ray scattering, and atomic force microscopy. Baicalein-stabilized oligomers are beta-sheet-enriched according to CD and Fourier transform infrared spectroscopy analyses. They did not form fibrils even after very prolonged incubation. From small-angle X-raymore » scattering data and atomic force microscopy images, the oligomers were characterized as quite compact globular species. Oligomers were extremely stable, with a GdmCl C(m)=3.3 M. This high stability explains the previously observed inhibition properties of baicalein against alpha-synuclein fibrillation. These baicalein-stabilized oligomers, added to the solution of aggregating alpha-synuclein, were able to noticeably inhibit its fibrillation. After prolonged coincubation, short fibrils were formed, suggesting an effective interaction of oligomers with monomeric alpha-synuclein. Membrane permeability tests suggested that the baicalein-stabilized oligomers had a mild effect on the integrity of the membrane surface. This effect was rather similar to that of the monomeric protein, suggesting that targeted stabilization of certain alpha-synuclein oligomers might offer a potential strategy for the development of novel Parkinson's disease therapies.« less

  16. Analytical capabilities of high performance liquid chromatography - Atmospheric pressure photoionization - Orbitrap mass spectrometry (HPLC-APPI-Orbitrap-MS) for the trace determination of novel and emerging flame retardants in fish.

    PubMed

    Zacs, D; Bartkevics, V

    2015-10-22

    A new analytical method was established and validated for the analysis of 27 brominated flame retardants (BFRs), including so called "emerging" and "novel" BFRs (EBFRs and NBFRs) in fish samples. High performance liquid chromatography (HPLC) coupled to Orbitrap mass spectrometry (Orbitrap-MS) employing atmospheric pressure photoionization (APPI) interface operated in negative mode was used for the identification/quantitation of contaminants. HPLC-Orbitrap-MS analysis provided a fast separation of selected analytes within 14 min, thus demonstrating a high throughput processing of samples. The developed methodology was tested by intralaboratory validation in terms of recovery, repeatability, linear calibration ranges, instrumental and method limits of quantitation (i-LOQ and m-LOQ), and where possible, trueness was verified by analysis of certified reference materials (CRMs). Recoveries of analytes were between 80 and 119%, while the repeatability in terms of relative standard deviations (RSDs) was in the range from 1.2 to 15.5%. The measured values for both analyzed CRMs agreed with the provided consensus values, revealing the recovery of reference concentrations in 72-119% range. The elaborated method met the sensitivity criterion according to Commission Recommendation 2014/118/EU on monitoring of BFRs in food products for majority of the compounds. The concentrations of polybrominated diphenyl ethers (PBDEs) in real samples determined by HPLC-APPI-Orbitrap-MS method and validated gas chromatography-high-resolution mass spectrometry (GC-HRMS) method were found to be in a good agreement. Copyright © 2015 Elsevier B.V. All rights reserved.

  17. Fluorescent adduct formation with terbium: a novel strategy for transferrin glycoform identification in human body fluids and carbohydrate-deficient transferrin HPLC method validation.

    PubMed

    Sorio, Daniela; De Palo, Elio Franco; Bertaso, Anna; Bortolotti, Federica; Tagliaro, Franco

    2017-02-01

    This paper puts forward a new method for the transferrin (Tf) glycoform analysis in body fluids that involves the formation of a transferrin-terbium fluorescent adduct (TfFluo). The key idea is to validate the analytical procedure for carbohydrate-deficient transferrin (CDT), a traditional biochemical serum marker to identify chronic alcohol abuse. Terbium added to a human body-fluid sample produced TfFluo. Anion exchange HPLC technique, with fluorescence detection (λ exc 298 nm and λ em 550 nm), permitted clear separation and identification of Tf glycoform peaks without any interfering signals, allowing selective Tf sialoforms analysis in human serum and body fluids (cadaveric blood, cerebrospinal fluid, and dried blood spots) hampered for routine test. Serum samples (n = 78) were analyzed by both traditional absorbance (Abs) and fluorescence (Fl) HPLC methods and CDT% levels demonstrated a significant correlation (p < 0.001 Pearson). Intra- and inter-runs CV% was 3.1 and 4.6%, respectively. The cut-off of 1.9 CDT%, related to the HPLC Abs proposed as the reference method, by interpolation in the correlation curve with the present method demonstrated a 1.3 CDT% cut-off. Method comparison by Passing-Bablok and Bland-Altman tests demonstrated Fl versus Abs agreement. In conclusion, the novel method is a reliable test for CDT% analysis and provides a substantial analytical improvement offering important advantages in terms of types of body fluid analysis. Its sensitivity and absence of interferences extend clinical applications being reliable for CDT assay on body fluids usually not suitable for routine test. Graphical Abstract The formation of a transferrin-terbium fluorescent adduct can be used to analyze the transferrin glycoforms. The HPLC method for carbohydrate-deficient transferrin (CDT%) measurement was validated and employed to determine the levels in different body fluids.

  18. Quantification of astaxanthin in shrimp waste hydrolysate by HPLC.

    PubMed

    López-Cervantes, J; Sánchez-Machado, D I; Gutiérrez-Coronado, M A; Ríos-Vázquez, N J

    2006-10-01

    In the present study, a simple and rapid reversed-phase HPLC method for the determination of astaxanthin in shrimp waste hydrolysate has been developed and validated. The analytical procedure involves the direct extraction of astaxanthin from the lipid fraction with methanol. The analytical column, SS Exil ODS, was operated at 25C. The mobile phase consisted of a mixture of water:methanol:dichloromethane:acetonitrile (4.5:28:22:45.5 v/v/v/v) at a flow rate of 1.0 mL/min. Detection and identification were performed using a photodiode array detector (lambda(detection) = 476 nm). The proposed HPLC method showed adequate linearity, repeatability and accuracy.

  19. Pharmacokinetic study of arctigenin in rat plasma and organ tissue by RP-HPLC method.

    PubMed

    He, Fan; Dou, De-Qiang; Hou, Qiang; Sun, Yu; Kang, Ting-Guo

    2013-01-01

    A high-performance liquid chromatography (HPLC) technique was developed for the determination of arctigenin in plasma and various organs of rats after the oral administration of 30, 50 and 70 mgkg(-1) of arctigenin to the Sprague-Dawley rats. Results showed that the validated HPLC method was simple, fast, reproducible and suitable to the determination of arctigenin in rat plasma and organ tissue and one-compartmental model with zero-order absorption process can well describe the changes of arctigenin concentration in the plasma. The concentration of compound was highest in the spleen, less in the liver and the least in the lung.

  20. Simultaneous determination of bioactive constituents in Danggui Buxue Tang for quality control by HPLC coupled with a diode array detector, an evaporative light scattering detector and mass spectrometry.

    PubMed

    Yi, Ling; Qi, Lian-Wen; Li, Ping; Ma, Yi-Han; Luo, Yong-Jing; Li, Hai-Yun

    2007-09-01

    Danggui Buxue Tang (DBT), a classical traditional Chinese formula comprising Radix Angelicae Sinensis (RAS) and Radix Astragali (RA), has been widely used to treat menopausal irregularity in Chinese women for nearly 800 years. In this study, a comprehensive analytical method of simultaneously determining the main types of bioactive constituents, eighteen in all from the formula, involving flavonoids, saponins, organic acid and some volatile compounds, was developed. This method was based on HPLC coupled to a diode array and evaporative light scattering detectors (HPLC-DAD-ELSD) on a common reverse-phase C(18) column. Liquid chromatography coupled with on-line electrospray ionization mass spectrometry (LC-ESI-MS) was also used to further validate and analyze the constituents. It was found that 0.3% aqueous formic acid and acetonitrile was the optimum mobile phase for gradient elution. This method, which showed good precision and accuracy, was successfully used to quantify the bioactive constituents in six products. As a result, the validated HPLC method, together with the LC-ESI-MS analysis, provided a new basis for assessing the quality of traditional Chinese medicinal compound preparations (TCMCPs) consisting of many bioactive components.

  1. Simultaneous qualitative and quantitative analysis of phenolic acids and flavonoids for the quality control of Apocynum venetum L. leaves by HPLC-DAD-ESI-IT-TOF-MS and HPLC-DAD.

    PubMed

    An, Haijuan; Wang, Hong; Lan, Yuexiang; Hashi, Yuki; Chen, Shizhong

    2013-11-01

    A reliable method based on high performance liquid chromatography-diode array detector-electrospray ionization-ion trap-time of flight-mass spectrometry (HPLC-DAD-ESI-IT-TOF-MS) was developed for the identification of phenolic acids and flavonoids in Apocynum venetum L. leaves and its adulterant, Pocynum hendersonii (Hook. f.) Woodson leaves. A total of 21 compounds were identified or tentatively identified, including 4 phenolic acids and 17 flavonoids. 3-O-caffeoylquinic acid (3-CQA) and caffeic acid were detected for the first time in A. venetum leaves; 4-O-caffeoylquinic acid (4-CQA), 3-CQA, caffeic acid, quercetin-3-O-(6"-O-malonyl)-galactoside, quercetin-3-O-(6"-O-malonyl)-glucoside, kaempferol-3-O-(6"-O-malonyl)-glucoside, kaempferol-3-O-(6"-O-acetyl)-glucoside, and kaempferol-3-O-dihexoside were detected for the first time in P. hendersonii leaves. Cluster analysis was employed to analyze 24 batches of A. venetum leaves and 5 batches of P. hendersonii leaves collected from various regions in China. The analysis, which was based on the 21 compounds, indicated that profiles of these compounds were distinct between the two species, and among A. venetum leaf samples from different origins. 18 of these 21 compounds were selected as the markers and simultaneously analyzed by HPLC-DAD for the first time. The quantitative analytical method was validated and subsequently applied to the comprehensive quality evaluation of 24 batches of A. venetum leaves. © 2013 Elsevier B.V. All rights reserved.

  2. Chemical stability of reactive skin decontamination lotion (RSDL®).

    PubMed

    Bogan, R; Maas, H J; Zimmermann, T

    2018-09-01

    Reactive Skin Decontamination Lotion (RSDL ® ) is used for the decontamination of Chemical Warfare Agents and Toxic Industrial Compounds after dermal exposure. It has to be stockpiled over a long period and is handled in all climatic zones. Therefore stability is an essential matter of concern. In this work we describe a study to the chemical stability of RSDL ® as basis for an estimation of shelf life. We analysed RSDL ® for the active ingredient 2,3-butandione monoxime (diacetylmonooxime, DAM), the putative degradation product dimethylglyoxime (DMG) and unknown degradation products by means of a reversed phase high pressure liquid chromatography (HPLC). Calculations were done according to the Arrhenius equation. Based on the temperature dependent rate constants, the time span was calculated, until defined threshold values for DAM and DMG subject to specification and valid regulations were exceeded. The calculated data were compared to the ones gathered from stockpiled samples and samples exposed during foreign mission. The decline of DAM followed first order kinetics, while formation of DMG could be described by zero order kinetics. The rate constants were distinctively temperature dependent. Calculated data were in good accordance to the measured ones from stockpile and mission. Based on a specified acceptable DAM-content of 90% and a valid threshold value of 0.1% (w/w) for the degradation product DMG, RSDL ® proved to be stable for at least four years if stored at the recommended conditions of 15°C-30°C. If continuously stored at higher temperatures shelf life will decrease markedly. Therefore RSDL ® is an object for risk orientated quality monitoring during storage. Copyright © 2017 Elsevier B.V. All rights reserved.

  3. Degradation of the Alternaria mycotoxins alternariol, alternariol monomethyl ether, and altenuene upon bread baking.

    PubMed

    Siegel, David; Feist, Michael; Proske, Matthias; Koch, Matthias; Nehls, Irene

    2010-09-08

    The stability of the Alternaria mycotoxins alternariol, alternariol monomethyl ether, and altenuene upon bread baking was investigated by model experiments using a spiked wholemeal wheat flour matrix. For alternariol and alternariol monomethyl ether, but not for altenuene, degradation products, formed through a sequence of hydrolysis and decarboxylation, could be identified in pilot studies. The simultaneous quantification of alternariol, alternariol monomethyl ether, altenuene, and the degradation products was achieved by a newly developed high performance liquid chromatography tandem mass spectrometry (HPLC-MS/MS) multimethod. The obtained quantitative data indicate that the Alternaria mycotoxins are barely degraded during wet baking, while significant degradation occurs upon dry baking, with the stability decreasing in the order alternariol monomethyl ether>alternariol>altenuene. The novel degradation products could be detected after the wet baking of flour spiked with alternariol and in a sample survey of 24 commercial cereal based baking products.

  4. Development and validation of a stability-indicating LC method for the assay of lodenafil carbonate in tablets.

    PubMed

    Codevilla, Cristiane Franco; Lemos, Alice Machado; Delgado, Leila Schreiner; Rolim, Clarice Madalena Bueno; Adams, Andréa Inês Horn; Bergold, Ana Maria

    2011-08-01

    A stability-indicating liquid chromatographic method has been developed for the quantitative determination of lodenafil carbonate in tablets. The method employs a Synergi Fusion C18 column (250 × 4.6 mm, i.d., 4 μm particle size), with mobile phase consisting of a mixture of methanol-acetic acid 0.1% pH 4.0 (65:35, v/v) and UV detection at 290 nm, using a photodiode array detector. A linear response (r = 0.9999) was observed in the range of 10-80 μg/mL. The method showed good recoveries (average 100.3%) and also intra and inter-day precision (RSD < 2.0%). Validation parameters as specificity and robustness were also determined. Specificity analysis showed that no impurities or degradation products were co-eluting with the lodenafil carbonate peak. The method was found to be stability-indicating and due to its simplicity and accuracy can be applied for routine quality control analysis of lodenafil carbonate in tablets.

  5. Stability indicating simplified HPLC method for simultaneous analysis of resveratrol and quercetin in nanoparticles and human plasma.

    PubMed

    Kumar, Sandeep; Lather, Viney; Pandita, Deepti

    2016-04-15

    Resveratrol and quercetin are well-known polyphenolic compounds present in common foods, which have demonstrated enormous potential in the treatment of a wide variety of diseases. Owing to their exciting synergistic potential and combination delivery applications, we developed a simple and rapid RP-HPLC method based on isosbestic point detection. The separation was carried out on phenomenex Synergi 4μ Hydro-RP 80A column using methanol: acetonitrile (ACN): 0.1% phosphoric acid (60:10:30) as mobile phase. The method was able to quantify nanograms of analytes simultaneously on a single wavelength (269 nm), making it highly sensitive, rapid as well as economical. Additionally, forced degradation studies of resveratrol and quercetin were established and the method's applicability was evaluated on PLGA nanoparticles and human plasma. The analytes peaks were found to be well resolved in the presence of degradation products and excipients. The simplicity of the developed method potentializes its suitability for routine in vitro and in vivo analysis of resveratrol and quercetin. Copyright © 2015 Elsevier Ltd. All rights reserved.

  6. Stability studies on diloxanide furoate: effect of pH, temperature, gastric and intestinal fluids.

    PubMed

    Gadkariem, E A; Belal, F; Abounassif, M A; El-Obeid, H A; E E Ibrahim, K

    2004-04-01

    The degradation of the amoebicide diloxanide furoate in alkaline medium at different temperatures was investigated using both a spectrophotometric and a developed HPLC method. In solutions, the drug was found to undergo decomposition, i.e., temperature and pH dependent. The pH-rate profile at pH between 7.6 and 9.6 indicated a first-order dependence of Kobs on [-OH]. Arrhenius plot obtained at pH 8 was linear between 40 and 63 degrees C. The estimated activation energy of hydrolysis was found to be 18.25 kcal degree.mol(-1). The effect of simulated gastric and intestinal fluids on the drug was also investigated. A new thin-layer chromatographic (TLC) procedure for the fractionation of the drug and its alkaline hydrolysis products has been developed and was found to compare favorably with that of the British Pharmacopoeia. Three hydrolysis products of a basic methanolic solution of the drug, namely furoic acid, diloxanide and methylfuroate could be identified by the use of TLC, HPLC, infrared and mass spectrometry.

  7. Photochemical transformation of azoxystrobin in aqueous solutions.

    PubMed

    Boudina, A; Emmelin, C; Baaliouamer, A; Païssé, O; Chovelon, J M

    2007-07-01

    The photochemical behaviour of azoxystrobin fungicide (AZX) in water was studied under laboratory conditions. Photodegradation was initiated using a solar simulator (xenon arc lamp) or a jacketed Pyrex reaction cell equipped with a 125 W, high-pressure mercury lamp. HPLC/MS analysis (APCI and ESI in positive and negative modes) was used to identify AZX photoproducts. The calculated polychromatic quantum efficiencies (phi) of AZX at pH 4.5, 7 and 9 were 5.42 x 10(-3), 3.47 x 10(-3) and 3.06 x 10(-3) (degraded molecules per absorbed photon), respectively. The relatively narrow range of values indicates the stability of AZX with respect to photodegradation in the studied pH range. Results from the HPLC/MS analysis suggest that the phototransformation of AZX proceeds via multiple, parallel reaction pathways including: (1) photo-isomerization (E-->Z), (2) photo-hydrolysis of the methyl ester and of the nitrile group, (3) cleavage of the acrylate double bond, (4) photohydrolytic ether cleavage between the aromatic ring giving phenol, and (5) oxidative cleavage of the acrylate double bond.

  8. Stability of piritramide in patient-controlled analgesia (PCA) solutions.

    PubMed

    Remane, D; Scriba, G; Meissner, W; Hartmann, M

    2009-06-01

    For patient controlled analgesia, syringes with solutions of 1.5 mg/ml piritramide in 0.9% aqueous sodium chloride are used. The physical and chemical stability for dilutions of the commercially available preparation of piritramide is limited up to 72 hours by the manufacturer. Since application duration for patient-controlled analgesia can exceed that limited time, stability was investigated by HPLC. Our results show that these solutions are chemically stable over a time period of 60 days.

  9. Investigations Concerning Hydrolysis and Stabilization of Antiradiation Compounds

    DTIC Science & Technology

    1982-01-01

    Stability of Unencapsulated WR 2721 31 V. DISCUSSION 35 A. Microencapsulation 35 1. Microspheres 35 2. Microcapsules 35 B. Hydrolytic Stability of...in 1.5 hours at 370C in buffered solutions of pH 1.0 or 3.0. 3^ The more promising microspheres and microcapsules released the WR 2721 within two...hours at pH 7.5 in buffered solutions. 4) Analytical procedures were developed for: "♦ WR 2721 (directly) in microcapsules using an HPLC

  10. Reversed phase HPLC analysis of stability and microstructural effects on degradation kinetics of β-carotene encapsulated in freeze-dried maltodextrin-emulsion systems.

    PubMed

    Harnkarnsujarit, Nathdanai; Charoenrein, Sanguansri; Roos, Yrjö H

    2012-09-26

    Degradation of dispersed lipophilic compounds in hydrophilic solids depends upon matrix stability and lipid physicochemical properties. This study investigated effects of solid microstructure and size of lipid droplets on the stability of dispersed β-carotene in freeze-dried systems. Emulsions of β-carotene in sunflower oil were dispersed in maltodextrin systems (M040/DE6, M100/DE11, and M250/DE25.5) (8% w/w oil) and prefrozen at various freezing conditions prior to freeze-drying to control nucleation and subsequent pore size and structural collapse of freeze-dried solids. The particle size, physical state, and β-carotene contents of freeze-dried emulsions were measured during storage at various water activity (a(w)) using a laser particle size analyzer, differential scanning calorimeter, and high performance liquid chromatography (HPLC), respectively. The results showed that M040 stabilized emulsions in low temperature freezing exhibited lipid crystallization. Collapse of solids in storage at a(w) which plasticized systems to the rubbery state led to flow and increased the size of oil droplets. Degradation of β-carotene analyzed using a reversed-phase C(30) column followed first-order kinetics. Porosity of solids had a major effect on β-carotene stability; however, the highest stability was found in fully plasticized and collapsed solids.

  11. Physical and Chemical Stability of Mycophenolate Mofetil (MMF) Suspension Prepared at the Hospital

    PubMed Central

    Fahimi, Fanak; Baniasadi, Shadi; Mortazavi, Seyed Alireza; Dehghan, Hanie; Zarghi, Afshin

    2012-01-01

    To evaluate the physical and chemical stability of a suspension of mycophenolate mofetil (MMF) prepared in the hospital from commercially available MMF capsules and tablets. Extemporaneous pharmacy was used as a feasible method in this experimental study to prepare suspension form of MMF. Suspension formulations were prepared from both tablets and capsules forms of MMF. Thereafter the stability parameters such as pH, microbial control, thermal and physical stability and particle sizes were evaluated. The amount of MMF, in the suspension was measured at various time points by HPLC. The HPLC method showed that concentration of suspensions prepared from tablets and capsules were 49 mg/mL and 50 mg/mL at time 0, respectively. The effective amount of suspensions prepared from capsules was 101% at time 0, 100% after 7 days, 98% after 14 days, and less than 70% after 28 days. According to the obtained results in this study, capsule-based suspension was stable for as long as 14 days at 5°C. This formulation appears to be clinically acceptable and provides a convenient dosage form for pediatric patients and for adults during the early postoperative period. PMID:24250439

  12. Novel Validated RP-HPLC Method for Bendamustine Hydrochloride Based on Ion-pair Chromatography: Application in Determining Infusion Stability and Pharmacokinetics.

    PubMed

    Singh, Yuvraj; Chandrashekar, Anumandla; Pawar, Vivek K; Saravanakumar, Veeramuthu; Meher, Jayagopal; Raval, Kavit; Singh, Pankaj; Kumar, R Dinesh; Chourasia, Manish K

    2017-01-01

    Ion pair chromatography was used for quantifying bendamustine hydrochloride (BH) in its marketed vial. The permissive objective was to investigate time duration for which highly susceptible drug content of the marketed vial remained stable after reconstitution. However, the method could also be used to measure extremely low levels of drug in rat plasma and a pharmacokinetic study was accordingly conducted to further showcase method's applicability. Optimized separation was achieved on C-18 Purospher ® STAR (250 mm × 4.6 mm, 5 μm particle size) column. Mobile phase flowing at 1.5 mL/min consisted of 5 mM sodium salt of octane sulfonic acid dissolved in methanol, water and glacial acetic acid (55:45:0.075) maintained at pH 6. Detection was carried out at 233 nm with BH eluting after 7.8 min. Validation parameters were determined as per ICH guidelines. Limit of detection and limit of quantification were found to be 0.1 µg/mL and 0.33 µg/mL, respectively. The recoveries were 98-102% in bulk and 85-91% in plasma. The developed method was specific for BH, and utilized for assessing its short-term stability in physiologic solvents and forced degradation products in acid, base, oxidative, light and temperature induced stress environments. © The Author 2016. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.

  13. High-throughput metabolic stability studies in drug discovery by orthogonal acceleration time-of-flight (OATOF) with analogue-to-digital signal capture (ADC).

    PubMed

    Temesi, David G; Martin, Scott; Smith, Robin; Jones, Christopher; Middleton, Brian

    2010-06-30

    Screening assays capable of performing quantitative analysis on hundreds of compounds per week are used to measure metabolic stability during early drug discovery. Modern orthogonal acceleration time-of-flight (OATOF) mass spectrometers equipped with analogue-to-digital signal capture (ADC) now offer performance levels suitable for many applications normally supported by triple quadruple instruments operated in multiple reaction monitoring (MRM) mode. Herein the merits of MRM and OATOF with ADC detection are compared for more than 1000 compounds screened in rat and/or cryopreserved human hepatocytes over a period of 3 months. Statistical comparison of a structurally diverse subset indicated good agreement for the two detection methods. The overall success rate was higher using OATOF detection and data acquisition time was reduced by around 20%. Targeted metabolites of diazepam were detected in samples from a CLint determination performed at 1 microM. Data acquisition by positive and negative ion mode switching can be achieved on high-performance liquid chromatography (HPLC) peak widths as narrow as 0.2 min (at base), thus enabling a more comprehensive first pass analysis with fast HPLC gradients. Unfortunately, most existing OATOF instruments lack the software tools necessary to rapidly convert the huge amounts of raw data into quantified results. Software with functionality similar to open access triple quadrupole systems is needed for OATOF to truly compete in a high-throughput screening environment. Copyright 2010 John Wiley & Sons, Ltd.

  14. Formulation and characterization of a 0.1% rapamycin cream for the treatment of Tuberous Sclerosis Complex-related angiofibromas.

    PubMed

    Bouguéon, Guillaume; Lagarce, Frédéric; Martin, Ludovic; Pailhoriès, Hélène; Bastiat, Guillaume; Vrignaud, Sandy

    2016-07-25

    Medicines for the treatment of rare diseases frequently do not attract the interest of the pharmaceutical industry, and hospital pharmacists are thus often requested by physicians to prepare personalized medicines. Tuberous Sclerosis Complex (TSC) is a rare disease that causes disfiguring lesions named facial angiofibromas. Various topical formulations of rapamycin (=sirolimus) have been proved effective in treating these changes in small case series. The present study provides for the first time characterization of a 0.1% rapamycin cream formulation presenting good rapamycin solubilisation. The first step of the formulation is solubilisation of rapamycin in Transcutol(®), and the second step is the incorporation of the mixture in an oil-in-water cream. A HPLC stability-indicating method was developed. Rapamycin concentration in the cream was tested by HPLC and confirmed that it remained above 95% of the initial concentration for at least 85days, without characteristic degradation peaks. The preparation met European Pharmacopoeia microbial specifications throughout storage in aluminum tubes, including when patient use was simulated. Odour, appearance and colour of the preparation were assessed and no change was evidenced during storage. The rheological properties of the cream also remained stable throughout storage. To conclude, we report preparation of a novel cream formulation presenting satisfactory rapamycin solubilisation for the treatment of TSC cutaneous manifestations, with stability data. The cream is currently being used by our patients. Efficacy and tolerance will be reported later. Copyright © 2016 Elsevier B.V. All rights reserved.

  15. Encapsulation of β-carotene within ferritin nanocages greatly increases its water-solubility and thermal stability.

    PubMed

    Chen, Lingli; Bai, Guangling; Yang, Rui; Zang, Jiachen; Zhou, Ting; Zhao, Guanghua

    2014-04-15

    Carotenoids may play a number of potential health benefits for human. However, their use in food industry is limited mostly because of their poor water-solubility and low thermal stability. Ferritins are widely distributed in nature with a shell-like structure which offers a great opportunity to improve the water-solubility and thermal stability of the carotenoids by encapsulation. In this work, recombinant human H-chain ferritin (rHuHF) was prepared and used to encapsulate β-carotene, a typical compound among carotenoids, by taking advantage of the reversible dissociation and reassembly characteristic of apoferritin in different pH environments. Results from high-performance liquid chromatography (HPLC), UV/Vis spectroscopy and transmission electron microscope (TEM) indicated that β-carotene molecules were successfully encapsulated within protein cages with a β-carotene/protein molar ratio of 12.4-1. Upon such encapsulation, these β-carotene-containing apoferritin nanocomposites were water-soluble. Interestingly, the thermal stability of the β-carotene encapsulated within apoferritin nanocages was markedly improved as compared to free β-carotene. These new properties might be favourable to the utilisation of β-carotene in food industry. Copyright © 2013 Elsevier Ltd. All rights reserved.

  16. Quantification of maltol in Korean ginseng (Panax ginseng) products by high-performance liquid chromatography-diode array detector

    PubMed Central

    Jeong, Hyun Cheol; Hong, Hee-Do; Kim, Young-Chan; Rhee, Young Kyoung; Choi, Sang Yoon; Kim, Kyung-Tack; Kim, Sung Soo; Lee, Young-Chul; Cho, Chang-Won

    2015-01-01

    Background: Maltol, as a type of phenolic compounds, is produced by the browning reaction during the high-temperature treatment of ginseng. Thus, maltol can be used as a marker for the quality control of various ginseng products manufactured by high-temperature treatment including red ginseng. For the quantification of maltol in Korean ginseng products, an effective high-performance liquid chromatography-diode array detector (HPLC-DAD) method was developed. Materials and Methods: The HPLC-DAD method for maltol quantification coupled with a liquid-liquid extraction (LLE) method was developed and validated in terms of linearity, precision, and accuracy. An HPLC separation was performed on a C18 column. Results: The LLE methods and HPLC running conditions for maltol quantification were optimized. The calibration curve of the maltol exhibited good linearity (R2 = 1.00). The limit of detection value of maltol was 0.26 μg/mL, and the limit of quantification value was 0.79 μg/mL. The relative standard deviations (RSDs) of the data of the intra- and inter-day experiments were <1.27% and 0.61%, respectively. The results of the recovery test were 101.35–101.75% with an RSD value of 0.21–1.65%. The developed method was applied successfully to quantify the maltol in three ginseng products manufactured by different methods. Conclusion: The results of validation demonstrated that the proposed HPLC-DAD method was useful for the quantification of maltol in various ginseng products. PMID:26246746

  17. Analysis of iridoids, secoiridoids and xanthones in Centaurium erythraea, Frasera caroliniensis and Gentiana lutea using LC-MS and RP-HPLC.

    PubMed

    Aberham, Anita; Pieri, Valerio; Croom, Edward M; Ellmerer, Ernst; Stuppner, Hermann

    2011-02-20

    This study presents a new and validated HPLC method for the simultaneous determination of bioactive compounds in Centaurium erythraea, Frasera caroliniensis and Gentiana lutea. The iridoid loganic acid, four secoiridoids and 29 xanthones were separated on a RP-18 column, using aqueous o-phosphoric acid (0.085%, v/v) and acetonitrile as mobile phase. Phytochemical investigation of C. erythraea herb and F. caroliniensis roots resulted into isolation of 25 xanthones and three secoiridoids the structure of which was elucidated by spectroscopic means (NMR, MS and UV). 1,3,8-Trihydroxy-5,6-dimethoxyxanthone, isolated from C. erythraea, turned out to be a novel xanthone. The stability of the analytes was tested by subjecting samples to light, moisture and different temperatures. After six months of storage, decomposition of gentiopicroside and sweroside was observed. The swertiamarin content was nearly unchanged when stored at room temperature or in the refrigerator, but high temperature conditions reduced the content to 85%. In contrast, xanthones were stable under long-term, refrigerated and accelerated conditions. The established chromatographic method has been successfully applied for the quantification of the bioactive compounds in the three plants. The presence and distribution of polyoxygenated xanthones within the three members of the Gentianaceae family and their significance as analytical markers are discussed. Copyright © 2010 Elsevier B.V. All rights reserved.

  18. Development of an Advanced HPLC–MS/MS Method for the Determination of Carotenoids and Fat-Soluble Vitamins in Human Plasma

    PubMed Central

    Hrvolová, Barbora; Martínez-Huélamo, Miriam; Colmán-Martínez, Mariel; Hurtado-Barroso, Sara; Lamuela-Raventós, Rosa Maria; Kalina, Jiří

    2016-01-01

    The concentration of carotenoids and fat-soluble vitamins in human plasma may play a significant role in numerous chronic diseases such as age-related macular degeneration and some types of cancer. Although these compounds are of utmost interest for human health, methods for their simultaneous determination are scarce. A new high pressure liquid chromatography (HPLC)-tandem mass spectrometry (MS/MS) method for the quantification of selected carotenoids and fat-soluble vitamins in human plasma was developed, validated, and then applied in a pilot dietary intervention study with healthy volunteers. In 50 min, 16 analytes were separated with an excellent resolution and suitable MS signal intensity. The proposed HPLC–MS/MS method led to improvements in the limits of detection (LOD) and quantification (LOQ) for all analyzed compounds compared to the most often used HPLC–DAD methods, in some cases being more than 100-fold lower. LOD values were between 0.001 and 0.422 µg/mL and LOQ values ranged from 0.003 to 1.406 µg/mL, according to the analyte. The accuracy, precision, and stability met with the acceptance criteria of the AOAC (Association of Official Analytical Chemists) International. According to these results, the described HPLC-MS/MS method is adequately sensitive, repeatable and suitable for the large-scale analysis of compounds in biological fluids. PMID:27754400

  19. Synchrophasor-Assisted Prediction of Stability/Instability of a Power System

    NASA Astrophysics Data System (ADS)

    Saha Roy, Biman Kumar; Sinha, Avinash Kumar; Pradhan, Ashok Kumar

    2013-05-01

    This paper presents a technique for real-time prediction of stability/instability of a power system based on synchrophasor measurements obtained from phasor measurement units (PMUs) at generator buses. For stability assessment the technique makes use of system severity indices developed using bus voltage magnitude obtained from PMUs and generator electrical power. Generator power is computed using system information and PMU information like voltage and current phasors obtained from PMU. System stability/instability is predicted when the indices exceeds a threshold value. A case study is carried out on New England 10-generator, 39-bus system to validate the performance of the technique.

  20. Optimization and characterization of spray-dried IgG formulations: a design of experiment approach.

    PubMed

    Faghihi, Homa; Najafabadi, Abdolhosein Rouholamini; Vatanara, Alireza

    2017-10-24

    The purpose of the present study is to optimize a spray-dried formulation as a model antibody regarding stability and aerodynamic property for further aerosol therapy of this group of macromolecules. A three-factor, three-level, Box-Behnken design was employed milligrams of Cysteine (X 1 ), Trehalose (X 2 ), and Tween 20 (X 3 ) as independent variables. The dependent variables were quantified and the optimized formulation was prepared accordingly. SEC-HPLC and FTIR-spectroscopy were conducted to evaluate the molecular and structural status of spray-dried preparations. Particle characterization of optimized sample was performed with the aid of DSC, SEM, and TSI examinations. Experimental responses of a total of 17 formulations resulted in yield values, (Y 1 ), ranging from 21.1 ± 0.2 to 40.2 ± 0.1 (%); beta-sheet content, (Y 2 ), from 66.22 ± 0.19 to 73.78 ± 0.26 (%); amount of aggregation following process, (Y 3 ), ranging from 0.11 ± 0.03 to 0.95 ± 0.03 (%); and amount of aggregation upon storage, (Y 4 ), from 0.81 ± 0.01 to 3.13 ± 0.64 (%) as dependent variables. Results-except for those of the beta sheet content-were fitted to quadratic models describing the inherent relationship between main factors. Co-application of Cysteine and Tween 20 preserved antibody molecules from molecular degradation and improved immediate and accelerated stability of spry-dried antibodies. Validation of the optimization study indicated high degree of prognostic ability of response surface methodology in preparation of stable spray-dried IgG. Graphical abstract Spray drying of IgG in the presence of Trehalose, Cysteine and Tween 20.

  1. Quantification of 5'-deoxy-5'-methylthioadenosine in heat-treated natural rubber latex serum.

    PubMed

    Pitakpornpreecha, Thanawat; Plubrukarn, Anuchit; Wititsuwannakul, Rapepun

    2012-01-01

    5'-Deoxy-5'-methylthioadenosine (MTA) is one of the biologically active components found in natural rubber latex (NRL) serum, a common waste product from rubber plantations. In this study the contents of MTA in heat-treated NRL serum were measured in order to assess the potential of the serum as an alternative source of MTA. To devise an HPLC/UV-based quantitative analytical protocol for the determination of MTA, and to determine the effect of heat treatment on the content of MTA in NRL serum from various sources. An HPLC/UV-based determination of MTA using an acidic eluant was devised and validated. In the heat treatment, the effect of refluxing times on MTA liberation was evaluated. The quantification protocol was validated with satisfying linearity, limits of detection and quantitation, precisions for peak areas and recovery percentages from intra- and inter-day operations. The amounts of MTA in the NRL sera from various sources increased with heat treatment to yield 5-12 μg MTA/mL of serum. The devised protocol was found to be satisfyingly applicable to the routine determination of MTA in NRL serum. The effect of heat treatment on the content of MTA also indicated another possible use for NRL serum, normally discarded in vast amounts by the rubber industry, as an alternative source of MTA. Copyright © 2011 John Wiley & Sons, Ltd.

  2. Selective Sorption of Dissolved Organic Carbon Compounds by Temperate Soils

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Jagadamma, Sindhu; Mayes, Melanie; Phillips, Jana Randolph

    Physico-chemical sorption of dissolved organic carbon (DOC) on soil minerals is one of the major processes of organic carbon (OC) stabilization in soils, especially in deeper layers. The attachment of C on soil solids is related to the reactivity of the soil minerals and the chemistry of the sorbate functional groups, but the sorption studies conducted without controlling microbial activity may overestimate the sorption potential of soil. This study was conducted to examine the sorptive characteristics of a diverse functional groups of simple OC compounds (D-glucose, L-alanine, oxalic acid, salicylic acid, and sinapyl alcohol) on temperate climate soil orders (Mollisols,more » Ultisols and Alfisols) with and without biological degradative processes. Equilibrium batch experiments were conducted using 0-100 mg C L-1 at a solid-solution ratio of 1:60 for 48 hrs and the sorption parameters were calculated by Langmuir model fitting. The amount of added compounds that remained in the solution phase was detected by high performance liquid chromatography (HPLC) and total organic C (TOC) analysis. Soil sterilization was performed by -irradiation technique and experiments were repeated to determine the contribution of microbial degradation to apparent sorption. Overall, Ultisols did not show a marked preference for apparent sorption of any of the model compounds, as indicated by a narrower range of maximum sorption capacity (Smax) of 173-527 mg kg soil-1 across compounds. Mollisols exhibited a strong preference for apparent sorption of oxalic acid (Smax of 5290 mg kg soil-1) and sinapyl alcohol (Smax of 2031 mg kg soil-1) over the other compounds. The propensity for sorption of oxalic acid is mainly attributed to the precipitation of insoluble Ca-oxalate due to the calcareous nature of most Mollisol subsoils and its preference for sinapyl alcohol could be linked to the polymerization of this lignin monomer on 2:2 mineral dominated soils. The reactivity of Alfisols to DOC was in between that of Ultisols and Mollisols. HPLC results revealed significantly higher sorption of D-glucose and L-alanine than did TOC results, and duplicate experiments with sterilized soils confirmed that glucose and alanine were mineralized leading to higher apparent sorption values via HPLC. This study demonstrated that three common temperate soil orders experienced differential sorption of simple OC compounds, indicating that sorbate chemistry plays a significant role in the sorptive stabilization of DOC.« less

  3. Partial Analysis of Insta-Foam

    NASA Technical Reports Server (NTRS)

    Chou, L. W.

    1983-01-01

    Insta-Foam, used as a thermal insulator for the non-critical area of the external tank during the prelaunch phase to minimize icing, is a two-component system. Component A has polyisocyanates, blowing agents, and stabilizers; Component B has the polyols, catalysts, blowing agents, stabilizers and fire retardant. The blowing agents are Freon 11 and Freon 12, the stabilizers are silicone surfactants, the catalysts are tertiary amines, and the fire retardant is tri-(beta-chloro-isopropyl) phosphate (PCF). High performance liquid chromatography (HPLC) was quantitatively identified polyols and PFC.

  4. Stability of Tranexamic Acid after 12-Week Storage at Temperatures from -20 deg C to 50 deg C

    DTIC Science & Technology

    2013-07-01

    PRELIMINARY REPORTS STABILITY OF TRANEXAMIC ACID AFTER 12-WEEK STORAGE AT TEMPERATURES FROM –20◦C TO 50◦C Rodolfo de Guzman, Jr., MT, I. Amy...Polykratis, BS, Jill L. Sondeen, PhD, Daniel N. Darlington, PhD, Andrew P. Cap, MD, PhD, Michael A. Dubick, PhD ABSTRACT Background. Tranexamic acid (TXA) is... tranexamic acid ; temperature stability; HPLC; thromboelastography; storage PREHOSPITAL EMERGENCY CARE 2013;17:394–400 BACKGROUND Hemorrhage is the leading

  5. Validation of blood vitamin A concentrations in cattle: comparison of a new cow-side test (iCheck™ FLUORO) with high-performance liquid chromatography (HPLC).

    PubMed

    Raila, Jens; Kawashima, Chiho; Sauerwein, Helga; Hülsmann, Nadine; Knorr, Christoph; Myamoto, Akio; Schweigert, Florian J

    2017-05-10

    Plasma concentration of retinol is an accepted indicator to assess the vitamin A (retinol) status in cattle. However, the determination of vitamin A requires a time consuming multi-step procedure, which needs specific equipment to perform extraction, centrifugation or saponification prior to high-performance liquid chromatography (HPLC). The concentrations of retinol in whole blood (n = 10), plasma (n = 132) and serum (n = 61) were measured by a new rapid cow-side test (iCheck™ FLUORO) and compared with those by HPLC in two independent laboratories in Germany (DE) and Japan (JP). Retinol concentrations in plasma ranged from 0.033 to 0.532 mg/L, and in serum from 0.043 to 0.360 mg/L (HPLC method). No significant differences in retinol levels were observed between the new rapid cow-side test and HPLC performed in different laboratories (HPLC vs. iCheck™ FLUORO: 0.320 ± 0.047 mg/L vs. 0.333 ± 0.044 mg/L, and 0.240 ± 0.096 mg/L vs. 0.241 ± 0.069 mg/L, lab DE and lab JP, respectively). A similar comparability was observed when whole blood was used (HPLC vs. iCheck™ FLUORO: 0.353 ± 0.084 mg/L vs. 0.341 ± 0.064 mg/L). Results showed a good agreement between both methods based on correlation coefficients of r 2  = 0.87 (P < 0.001) and Bland-Altman blots revealed no significant bias for all comparison. With the new rapid cow-side test (iCheck™ FLUORO) retinol concentrations in cattle can be reliably assessed within a few minutes and directly in the barn using even whole blood without the necessity of prior centrifugation. The ease of the application of the new rapid cow-side test and its portability can improve the diagnostic of vitamin A status and will help to control vitamin A supplementation in specific vitamin A feeding regimes such as used to optimize health status in calves or meat marbling in Japanese Black cattle.

  6. Development and application of a validated HPLC method for the analysis of dissolution samples of levothyroxine sodium drug products.

    PubMed

    Collier, J W; Shah, R B; Bryant, A R; Habib, M J; Khan, M A; Faustino, P J

    2011-02-20

    A rapid, selective, and sensitive gradient HPLC method was developed for the analysis of dissolution samples of levothyroxine sodium tablets. Current USP methodology for levothyroxine (L-T(4)) was not adequate to resolve co-elutants from a variety of levothyroxine drug product formulations. The USP method for analyzing dissolution samples of the drug product has shown significant intra- and inter-day variability. The sources of method variability include chromatographic interferences introduced by the dissolution media and the formulation excipients. In the present work, chromatographic separation of levothyroxine was achieved on an Agilent 1100 Series HPLC with a Waters Nova-pak column (250 mm × 3.9 mm) using a 0.01 M phosphate buffer (pH 3.0)-methanol (55:45, v/v) in a gradient elution mobile phase at a flow rate of 1.0 mL/min and detection UV wavelength of 225 nm. The injection volume was 800 μL and the column temperature was maintained at 28°C. The method was validated according to USP Category I requirements. The validation characteristics included accuracy, precision, specificity, linearity, and analytical range. The standard curve was found to have a linear relationship (r(2)>0.99) over the analytical range of 0.08-0.8 μg/mL. Accuracy ranged from 90 to 110% for low quality control (QC) standards and 95 to 105% for medium and high QC standards. Precision was <2% at all QC levels. The method was found to be accurate, precise, selective, and linear for L-T(4) over the analytical range. The HPLC method was successfully applied to the analysis of dissolution samples of marketed levothyroxine sodium tablets. Published by Elsevier B.V.

  7. Development and application of a validated HPLC method for the analysis of dissolution samples of levothyroxine sodium drug products

    PubMed Central

    Collier, J.W.; Shah, R.B.; Bryant, A.R.; Habib, M.J.; Khan, M.A.; Faustino, P.J.

    2011-01-01

    A rapid, selective, and sensitive gradient HPLC method was developed for the analysis of dissolution samples of levothyroxine sodium tablets. Current USP methodology for levothyroxine (l-T4) was not adequate to resolve co-elutants from a variety of levothyroxine drug product formulations. The USP method for analyzing dissolution samples of the drug product has shown significant intra- and inter-day variability. The sources of method variability include chromatographic interferences introduced by the dissolution media and the formulation excipients. In the present work, chromatographic separation of levothyroxine was achieved on an Agilent 1100 Series HPLC with a Waters Nova-pak column (250mm × 3.9mm) using a 0.01 M phosphate buffer (pH 3.0)–methanol (55:45, v/v) in a gradient elution mobile phase at a flow rate of 1.0 mL/min and detection UV wavelength of 225 nm. The injection volume was 800 µL and the column temperature was maintained at 28 °C. The method was validated according to USP Category I requirements. The validation characteristics included accuracy, precision, specificity, linearity, and analytical range. The standard curve was found to have a linear relationship (r2 > 0.99) over the analytical range of 0.08–0.8 µg/mL. Accuracy ranged from 90 to 110% for low quality control (QC) standards and 95 to 105% for medium and high QC standards. Precision was <2% at all QC levels. The method was found to be accurate, precise, selective, and linear for l-T4 over the analytical range. The HPLC method was successfully applied to the analysis of dissolution samples of marketed levothyroxine sodium tablets. PMID:20947276

  8. Ultrasound-assisted extraction of azadirachtin from dried entire fruits of Azadirachta indica A. Juss. (Meliaceae) and its determination by a validated HPLC-PDA method.

    PubMed

    de Paula, Joelma Abadia Marciano; Brito, Lucas Ferreira; Caetano, Karen Lorena Ferreira Neves; de Morais Rodrigues, Mariana Cristina; Borges, Leonardo Luiz; da Conceição, Edemilson Cardoso

    2016-01-01

    Azadirachta indica A. Juss., also known as neem, is a Meliaceae family tree from India. It is globally known for the insecticidal properties of its limonoid tetranortriterpenoid derivatives, such as azadirachtin. This work aimed to optimize the azadirachtin ultrasound-assisted extraction (UAE) and validate the HPLC-PDA analytical method for the measurement of this marker in neem dried fruit extracts. Box-Behnken design and response surface methodology (RSM) were used to investigate the effect of process variables on the UAE. Three independent variables, including ethanol concentration (%, w/w), temperature (°C), and material-to-solvent ratio (gmL(-1)), were studied. The azadirachtin content (µgmL(-1)), i.e., dependent variable, was quantified by the HPLC-PDA analytical method. Isocratic reversed-phase chromatography was performed using acetonitrile/water (40:60), a flow of 1.0mLmin(-1), detection at 214nm, and C18 column (250×4.6mm(2), 5µm). The primary validation parameters were determined according to ICH guidelines and Brazilian legislation. The results demonstrated that the optimal UAE condition was obtained with ethanol concentration range of 75-80% (w/w), temperature of 30°C, and material-to-solvent ratio of 0.55gmL(-1). The HPLC-PDA analytical method proved to be simple, selective, linear, precise, accurate and robust. The experimental values of azadirachtin content under optimal UAE conditions were in good agreement with the RSM predicted values and were superior to the azadirachtin content of percolated extract. Such findings suggest that UAE is a more efficient extractive process in addition to being simple, fast, and inexpensive. Copyright © 2015 Elsevier B.V. All rights reserved.

  9. Validation of HPLC method for the simultaneous and quantitative determination of 12 UV-filters in cosmetics.

    PubMed

    Nyeborg, M; Pissavini, M; Lemasson, Y; Doucet, O

    2010-02-01

    The aim of the study was the validation of a high-performance liquid chromatography (HPLC) method for the simultaneous and quantitative determination of twelve commonly used organic UV-filters (phenylbenzimidazole sulfonic acid, benzophenone-3, isoamyl p-methoxycinnamate, diethylamino hydroxybenzoyl hexyl benzoate, octocrylene, ethylhexyl methoxycinnamate, ethylhexyl salicylate, butyl methoxydibenzoylmethane, diethylhexyl butamido triazone, ethylhexyl triazone, methylene bis-benzotriazolyl tetramethylbutylphenol and bis-ethylhexyloxyphenol methoxyphenyl triazine) contained in suncare products. The separation and quantitative determination was performed in <30 min, using a Symmetry Shield(R) C18 (5 microm) column from Waters and a mobile phase (gradient mode) consisting of ethanol and acidified water. UV measurements were carried out at multi-wavelengths, according to the absorption of the analytes.

  10. [Continual improvement of quantitative analytical method development of Panax notogineng saponins based on quality by design].

    PubMed

    Dai, Sheng-Yun; Xu, Bing; Shi, Xin-Yuan; Xu, Xiang; Sun, Ying-Qiang; Qiao, Yan-Jiang

    2017-03-01

    This study is aimed to propose a continual improvement strategy based on quality by design (QbD). An ultra high performance liquid chromatography (UPLC) method was developed to accomplish the method transformation from HPLC to UPLC of Panax notogineng saponins (PNS) and achieve the continual improvement of PNS based on QbD, for example. Plackett-Burman screening design and Box-Behnken optimization design were employed to further understand the relationship between the critical method parameters (CMPs) and critical method attributes (CMAs). And then the Bayesian design space was built. The separation degree of the critical peaks (ginsenoside Rg₁ and ginsenoside Re) was over 2.0 and the analysis time was less than 17 min by a method chosen from the design space with 20% of the initial concentration of the acetonitrile, 10 min of the isocratic time and 6%•min⁻¹ of the gradient slope. At last, the optimum method was validated by accuracy profile. Based on the same analytical target profile (ATP), the comparison of HPLC and UPLC including chromatograph method, CMA identification, CMP-CMA model and system suitability test (SST) indicated that the UPLC method could shorten the analysis time, improve the critical separation and satisfy the requirement of the SST. In all, HPLC method could be replaced by UPLC for the quantity analysis of PNS. Copyright© by the Chinese Pharmaceutical Association.

  11. HPLC determination of strychnine and brucine in rat tissues and the distribution study of processed semen strychni.

    PubMed

    Chen, Jun; Hou, Ting; Fang, Yun; Chen, Zhi-peng; Liu, Xiao; Cai, Hao; Lu, Tu-lin; Yan, Guo-jun; Cai, Bao-chang

    2011-01-01

    A simple and low-cost HPLC method with UV absorbance detection was developed and validated to simultaneously determine strychnine and brucine, the most abundant alkaloids in the processed Semen Strychni, in rat tissues (kidney, liver, spleen, lung, heart, stomach, small intestine, brain and plasma). The tissue samples were treated with a simple liquid-liquid extraction prior to HPLC. The LOQs were in the range of 0.039-0.050 µg/ml for different tissue or plasma samples. The extraction recoveries varied from 71.63 to 98.79%. The linear range was 0.05-2 µg/ml with correlation coefficient of over 0.991. The intra- and inter-day precision was less than 15%. Then the method was used to measure the tissue distribution of strychnine and brucine after intravenous administration of 1 mg/kg crude alkaloids fraction (CAF) extracted from the processed Semen Strychni. The results revealed that strychnine and brucine possessed similar tissue distribution characterization. The highest level was observed in kidney, while the lowest level was found in brain. It was indicated that kidney might be the primary excretion organ of prototype strychnine and brucine. It was also deduced that strychnine and brucine had difficulty in crossing the blood-brain barrier. Furthermore, no long-term accumulation of strychnine and brucine was found in rat tissues.

  12. Fast and accurate determination of arsenobetaine in fish tissues using accelerated solvent extraction and HPLC-ICP-MS determination.

    PubMed

    Wahlen, Raimund

    2004-04-01

    A high-performance liquid chromatography-inductively coupled plasma-mass spectrometry (HPLC-ICP-MS) method has been developed for the fast and accurate analysis of arsenobetaine (AsB) in fish samples extracted by accelerated solvent extraction. The combined extraction and analysis approach is validated using certified reference materials for AsB in fish and during a European intercomparison exercise with a blind sample. Up to six species of arsenic (As) can be separated and quantitated in the extracts within a 10-min isocratic elution. The method is optimized so as to minimize time-consuming sample preparation steps and allow for automated extraction and analysis of large sample batches. A comparison of standard addition and external calibration show no significant difference in the results obtained, which indicates that the LC-ICP-MS method is not influenced by severe matrix effects. The extraction procedure can process up to 24 samples in an automated manner, yet the robustness of the developed HPLC-ICP-MS approach is highlighted by the capability to run more than 50 injections per sequence, which equates to a total run-time of more than 12 h. The method can therefore be used to rapidly and accurately assess the proportion of nontoxic AsB in fish samples with high total As content during toxicological screening studies.

  13. A single extraction and HPLC procedure for simultaneous analysis of phytosterols, tocopherols and lutein in soybeans.

    PubMed

    Slavin, Margaret; Yu, Liangli Lucy

    2012-12-15

    A saponification/extraction procedure and high performance liquid chromatography (HPLC) analysis method were developed and validated for simultaneous analysis of phytosterols, tocopherols and lutein (a carotenoid) in soybeans. Separation was achieved on a phenyl column with a ternary, isocratic solvent system of acetonitrile, methanol and water (48:22.5:29.5, v/v/v). Evaporative light scattering detection (ELSD) was used to quantify β-sitosterol, stigmasterol, campesterol, and α-, δ- and γ-tocopherols, while lutein was quantified with visible light absorption at 450 nm. Peak identification was verified by retention times and spikes with external standards. Standard curves were constructed (R(2)>0.99) to allow for sample quantification. Recovery of the saponification and extraction was demonstrated via analysis of spiked samples. Also, the accuracy of results of four soybeans using the described saponification and HPLC analytical method was validated against existing methods. This method offers a more efficient alternative to individual methods for quantifying lutein, tocopherols and sterols in soybeans. Copyright © 2012 Elsevier Ltd. All rights reserved.

  14. A validated solid-liquid extraction method for the HPLC determination of polyphenols in apple tissues Comparison with pressurised liquid extraction.

    PubMed

    Alonso-Salces, Rosa M; Barranco, Alejandro; Corta, Edurne; Berrueta, Luis A; Gallo, Blanca; Vicente, Francisca

    2005-02-15

    A solid-liquid extraction procedure followed by reversed-phase high-performance liquid chromatography (RP-HPLC) coupled with a photodiode array detector (DAD) for the determination of polyphenols in freeze-dried apple peel and pulp is reported. The extraction step consists in sonicating 0.5g of freeze-dried apple tissue with 30mL of methanol-water-acetic acid (30:69:1, v/v/v) containing 2g of ascorbic acid/L, for 10min in an ultrasonic bath. The whole method was validated, concluding that it is a robust method that presents high extraction efficiencies (peel: >91%, pulp: >95%) and appropriate precisions (within day: R.S.D. (n = 5) <5%, and between days: R.S.D. (n = 5) <7%) at the different concentration levels of polyphenols that can be found in apple samples. The method was compared with one previously published, consisting in a pressurized liquid extraction (PLE) followed by RP-HPLC-DAD determination. The advantages and disadvantages of both methods are discussed.

  15. Validation and application of HPLC-ESI-MS/MS method for the quantification of RBBR decolorization, a model for highly toxic molecules, using several fungi strains.

    PubMed

    Perlatti, Bruno; da Silva, Maria Fátima das Graças Fernandes; Fernandes, João Batista; Forim, Moacir Rossi

    2012-11-01

    A novel analytical method using HPLC-MS/MS operating in selected reaction monitoring (SRM) for evaluation of fungi efficacy to decolorize Remazol Brilliant Blue R (RBBR) dye solution was developed, validated and applied. The method shows high sensibility allowing the detection of 4.6 pM of RBBR. Four fungal strains were tested in liquid medium, three strains of Aspergillus (Aspergillus aculeatus, Aspergillus flavus and Aspergillus fumigatus) and Phanerochaete chrysosporium. All fungi were able to degrade the dye, with efficiencies ranging from 40% for P. chrysosporium up to 99% for A. flavus during a 30-day incubation period. During the experiment, increased accumulation of degradation products was observed in A. flavus cultures containing RBBR. Through the use of full scan HPLC-MS technique it was possible to propose the biogenesis of the microbial metabolic degradation pathway. Screening using microorganisms and RBBR may be hereafter used to investigate microbial biodegradation of high toxicity molecules such as dioxins. Copyright © 2012 Elsevier Ltd. All rights reserved.

  16. [Psychometric properties of a self-efficacy scale for physical activity in Brazilian adults].

    PubMed

    Rech, Cassiano Ricardo; Sarabia, Tais Taiana; Fermino, Rogério César; Hallal, Pedro Curi; Reis, Rodrigo Siqueira

    2011-04-01

    To test the validity and reliability of a self-efficacy scale for physical activity (PA) in Brazilian adults. A self-efficacy scale was applied jointly with a multidimensional questionnaire through face-to-face interviews with 1,418 individuals (63.4% women) aged ≥ 18 years. The scale was submitted to validity (factorial and construct) and reliability analysis (internal consistency and temporal stability). A test-retest procedure was conducted with 74 individuals to evaluate temporal stability. Exploratory factor analyses revealed two independent factors: self-efficacy for walking and self-efficacy for moderate and vigorous PA (MVPA). Together, these two factors explained 65.4% of the total variance of the scale (20.9% and 44.5% for walking and MVPA, respectively). Cronbach's alpha values were 0.83 for walking and 0.90 for MVPA, indicating high internal consistency. Both factors were significantly and positively correlated (rho ≥ 0.17, P < 0.001) with quality of life indicators (health perception, self-satisfaction, and energy for daily activities), indicating an adequate construct validity. The scale's validity, internal consistency, and reliability were adequate to evaluate self-efficacy for PA in Brazilian adults.

  17. A Stability-Indicating HPLC Method for the Determination of Memantine Hydrochloride in Dosage Forms through Derivatization with 1-Fluoro-2,4-dinitrobenzene

    PubMed Central

    Jalalizadeh, Hassan; Raei, Mahdi; Tafti, Razieh Fallah; Farsam, Hassan; Kebriaeezadeh, Abbas; Souri, Effat

    2014-01-01

    Memantine is chemically a tricyclic amine and is used for Parkinson’s disease and movement disorders. Although several HPLC methods with different derivatization reagents have been developed for the determination of memantine in biological fluids, there are some complications which limit the use of these methods in routine analysis of memantine in in vitro tests. We established a simple, sensitive, precise, and accurate HPLC method for the quantification of memantine in dosage forms. Pre-column derivatization of memantine was performed with 1-fluoro-2,4-dinitrobenzene and the reaction product was separated on a Nova-Pak C18 column. A mixture of acetonitrile and sodium dihydrogenphosphate (pH 2.5; 0.05 M) (70: 30, v/v) was used as the mobile phase. UV detection was performed at 360 nm. Forced degradation studies were performed on a powdered tablet sample of memantine hydro-chloride using acidic (0.1 M hydrochloric acid), basic (0.1 M sodium hydroxide), oxidative (10% hydrogen peroxide), thermal (105°C), photolytic, and humidity conditions. Good linearity (r2=0.999) was obtained over the range of 1–12 μg mL−1 of memantine hydrochloride with acceptable within-day and between-day precision values in the range of 0.05–0.95%. The proposed method was used for the assay determination and dissolution rate study of memantine dosage forms with excellent specificity. PMID:24959398

  18. Determination of Phenols Isomers in Water by Novel Nanosilica/Polydimethylsiloxane-Coated Stirring Bar Combined with High Performance Liquid Chromatography-Fourier Transform Infrared Spectroscopy.

    PubMed

    Zheng, Bei; Li, Wentao; Liu, Lin; Wang, Xin; Chen, Chen; Yu, Zhiyong; Li, Hongyan

    2017-08-18

    A novel nanosilica/polydimethylsiloxane (SiO 2 /PDMS) coated stirring bar was adopted in the sorption extraction (SBSE) of phenols in water, and the high performance liquid chromatography-fourier transform infrared spectroscopy (HPLC-FTIR) was subsequently used to determination of phenol concentration. The SiO 2 /PDMS coating was prepared by sol-gel method and characterized with respect to morphology and specific surface area. The results of field-emission scanning electron microscope (FE-SEM) and N 2 adsorption-desorption as well as phenol adsorption experiments denoted that SiO 2 /PDMS has larger surface area and better adsorption capacity than commercial PDMS. The extraction efficiency of phenol with SiO 2 /PDMS coated stirring bar was optimized in terms of ion strength, flow rate of phenol-involved influent, type of desorption solvent and desorption time. More than 75% of phenol desorption efficiency could be kept even after 50 cycles of extraction, indicating the high stability of the SiO 2 /PDMS coated stirring bar. Approximately 0.16 mg/L 2, 5-dimethylphenol (2, 5-DMP), which was 34-fold more toxic than phenol, was detected in water through HPLC-FTIR. However, 2, 5-DMP could be oxidized to 5-methy-2-hydroxy benzaldehyde after disinfection in drinking water treatment process. Therefore, the proposed method of SiO 2 /PDMS-SBSE-HPLC-FTIR is successfully applied in the analysis of phenols isomers in aqueous environment.

  19. Determination of Bortezomib in API Samples Using HPLC: Assessment of Enantiomeric and Diastereomeric Impurities.

    PubMed

    Kamalzadeh, Zahra; Babanezhad, Esmaeil; Ghaffari, Solmaz; Mohseni Ezhiyeh, Alireza; Mohammadnejad, Mahdieh; Naghibfar, Mehdi; Bararjanian, Morteza; Attar, Hossein

    2017-08-01

    A new, normal phase high performance liquid chromatography (NP-HPLC) method was developed for separation of Bortezomib (BZB) enantiomers and quantitative determination of (1S,2R)-enantiomer of BZB in active pharmaceutical ingredient (API) samples. The developed method was validated based on International Conference on Harmonisation (ICH) guidelines and it was proved to be accurate, precise and robust. The obtained resolution (RS) between the enantiomers was more than 2. The calibration curve for (1S,2R)-enantiomer was found to be linear in the concentration range of 0.24-5.36 mg/L with regression coefficient (R2) of 0.9998. Additionally, the limit of detection (LOD) and limit of quantification (LOQ) were 0.052 and 0.16 mg/L, respectively. Also, in this study, a precise, sensitive and robust gradient reversed-phase HPLC (RP-HPLC) method was developed and validated for determination of BZB in API samples. The detector response was linear over the concentration range of 0.26-1110.5 mg/L. The values of R2, LOD and LOQ were 0.9999, 0.084 and 0.25 mg/L, respectively. For both NP-HPLC and RP-HPLC methods, all of the RSD (%) values obtained in the precision study were <1.0%. System suitability parameters in terms of tailing factor (TF), number of theoretical plates (N) and RS were TF < 2.0, N > 2,000 and RS > 2.0. The performance of two common integration methods of valley to valley and drop perpendicular for drawing the baseline between two adjacent peaks were investigated for the determination of diastereomeric impurity (Imp-D) in the BZB-API samples. The results showed that the valley to valley method outperform the drop perpendicular method for calculation of Imp-D peak areas. Therefore, valley to valley method was chosen for peak integration. © The Author 2017. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.

  20. High-Performance Liquid Chromatography (HPLC) Quantification of Liposome-Delivered Doxorubicin in Arthritic Joints of Collagen-Induced Arthritis Rats.

    PubMed

    Niu, Hongqing; Xu, Menghua; Li, Shuangtian; Chen, Junwei; Luo, Jing; Zhao, Xiangcong; Gao, Chong; Li, Xiaofeng

    2017-04-14

    BACKGROUND Neoangiogenesis occurring in inflamed articular synovium in early rheumatoid arthritis (RA) is characterized by enhanced vascular permeability that allows nanoparticle agents, including liposomes, to deliver encapsulated drugs to arthritic joints and subsequently improve therapeutic efficacy and reduce adverse effects. However, the targeting distribution of liposomes in arthritic joints during RA has not been quantitatively demonstrated. We performed this study to evaluate the targeting distribution of PEGylated doxorubicin liposomes in the arthritic joints of collagen-induced arthritis (CIA) rats by high-performance liquid chromatography (HPLC). MATERIAL AND METHODS Two doxorubicin formulations were administered to CIA rats via tail intravenous injection at a single dose (50 mg/m²). CIA rats were sacrificed and the tissues of the inflamed ankle joints were collected. The content of doxorubicin in the arthritic joints was analyzed by a validated and reproducible HPLC method. A two-way ANOVA for 2×5 factorial design was used for statistical analysis. RESULTS The developed HPLC method was sensitive, precise, and reproducible. The method was successfully applied to quantify doxorubicin content in arthritic tissues. At each time point (6, 12, 24, 48, and 72 h), doxorubicin content in the arthritic joints of the doxorubicin liposome group (DOX-LIP group) was higher than in the free doxorubicin group (DOX group) (P<0.05). In the DOX-LIP group, doxorubicin levels in the arthritic joints increased gradually and significantly in the interval of 6-72 h post-administration. CONCLUSIONS PEGylated doxorubicin liposomes were targeted to, accumulated, and retained in the arthritic joints of CIA rats. The present study indicates that liposome encapsulation increases the therapeutic efficacy of antirheumatic drugs, presenting a promising therapeutic strategy for RA.

  1. HPLC determination of flavonoid glycosides in Mongolian Dianthus versicolor Fisch. (Caryophyllaceae) compared with quantification by UV spectrophotometry.

    PubMed

    Obmann, Astrid; Purevsuren, Sodnomtseren; Zehl, Martin; Kletter, Christa; Reznicek, Gottfried; Narantuya, Samdan; Glasl, Sabine

    2012-01-01

    Dianthus versicolor is used in traditional Mongolian medicine against liver impairment. Fractions enriched in flavone-di- and triglycosides were shown to enhance bile secretion. Therefore, reliable and accurate analytical methods are needed for the determination of these flavonoids in the crude drug and extracts thereof. To provide a validated HPLC-DAD (diode array detector) method especially developed for the separation of polar flavonoids and to compare the data obtained with those evaluated by UV spectrophotometry. Separations were carried out on an Aquasil® C₁₈-column (4.6 mm × 250.0 mm, 5 µm) with a linear gradient of acetonitrile and water (adjusted to pH 2.8 with trifluoroacetic acid) as mobile phase. Rutoside was employed as internal standard with linear behavior in a concentration range of 0.007-3.5 mg/mL. Accuracy was determined by spiking the crude drug with saponarin resulting in recoveries between 92% and 102%. The method allows the quantification of highly polar flavonoid glycosides and the determination of their total content. For saponarin a linear response was evaluated within the range 0.007-3.5 mg/mL (R²  > 0.9999). It was proven that threefold sonication represents a time-saving, effective and cheap method for the extraction of the polar flavonoid glycosides. The contents determined by HPLC were shown to be in agreement with those obtained employing UV spectrophotometry. The study has indicated that the newly developed HPLC method represents a powerful technique for the quality control of D. versicolor. Ultraviolet spectrophotometry may be used alternatively provided that the less polar flavonoids are removed by purification. Copyright © 2011 John Wiley & Sons, Ltd.

  2. Comparison of UPLC and HPLC methods for determination of vitamin C.

    PubMed

    Klimczak, Inga; Gliszczyńska-Świgło, Anna

    2015-05-15

    Ultra performance liquid chromatography (UPLC) and high-performance liquid chromatography (HPLC) methods for determination of ascorbic acid (AA) and total AA (TAA) contents (as the sum of AA and dehydroascorbic acid (DHAA) after its reduction to AA) in fruit beverages and in pharmaceutical preparations were compared. Both methods are rapid: total time of analysis was 15 and 6 min for HPLC and UPLC methods, respectively. The methods were validated in terms of linearity, instrument precision, limits of detection (LOD) and quantification (LOQ), accuracy and recovery. Intra- and inter-day instrument precisions for fruit juices, expressed as RSD, were 2.2% and 2.4% for HPLC, respectively, and 1.7% and 1.9% for UPLC, respectively. For vitamin C tablets, inter- and intra-day precisions were 0.4% and 0.5%, respectively (HPLC), and 0.5% and 0.3%, respectively (UPLC). Both methods were sensitive: LOD was 0.049 μg/mL for HPLC and 0.024 μg/mL for UPLC while LOQs were 0.149 and 0.073 μg/mL for HPLC and UPLC, respectively. These methods could be useful in the routine qualitative and quantitative analysis of AA or TAA in pharmaceutical preparations or fruit beverages. However, UPLC method is more sensitive, faster and consumes less eluent. Copyright © 2014 Elsevier Ltd. All rights reserved.

  3. Validation of a French version of the Sleep Condition Indicator: a clinical screening tool for insomnia disorder according to DSM-5 criteria.

    PubMed

    Bayard, Sophie; Lebrun, Cindy; Maudarbocus, Khaalid Hassan; Schellaert, Vanessa; Joffre, Alicia; Ferrante, Esther; Le Louedec, Marie; Cournoulat, Alice; Gely-Nargeot, Marie-Christine; Luik, Annemarie I

    2017-12-01

    Insomnia disorder is frequent in the population, yet there is no French screening instrument available that is based on the updated DSM-5 criteria. We evaluated the validity and reliability of the French version of an insomnia screening instrument based on DSM-5 criteria, the Sleep Condition Indicator, in a population-based sample of adults. A total of 366 community-dwelling participants completed a face-to-face clinical interview to determine insomnia disorder against DSM-5 criteria and several questionnaires including the French Sleep Condition Indicator version. Three-hundred and twenty-nine participants completed the Sleep Condition Indicator again after 1 month. Statistical analyses were performed to determine the reliability, construct validity, divergent validity and temporal stability of the French translation of the Sleep Condition Indicator. In addition, an explanatory factor analysis was performed to assess the underlying structure. The internal consistency (α = 0.87) and temporal stability (r = 0.86, P < 0.001) of the French Sleep Condition Indicator were high. When using the previously defined cut-off value of ≤ 16, the area under the receiver operating characteristic curve was 0.93 with a sensitivity of 95% and a specificity of 75%. Additionally, good construct and divergent validity were demonstrated. The factor analyses showed a two-factor structure with a focus on sleep and daytime effects. The French version of the Sleep Condition Indicator demonstrates satisfactory psychometric properties while being a useful instrument in detecting cases of insomnia disorder, consistent with features of DSM-5, in the general population. © 2017 European Sleep Research Society.

  4. The utilization of drug-polymer interactions for improving the chemical stability of hot-melt extruded solid dispersions.

    PubMed

    Guo, Zhefei; Lu, Ming; Li, Yongcheng; Pang, Huishi; Lin, Ling; Liu, Xu; Wu, Chuanbin

    2014-02-01

    Interactions between drugs and polymers were utilized to lower the processing temperature of hot-melt extrusion (HME), and thus minimize the thermal degradation of heat-sensitive drugs during preparation of amorphous solid dispersions. Diflunisal (DIF), which would degrade upon melting, was selected as a model drug. Hydrogen bonds between DIF and polymeric carriers (PVP K30, PVP VA64, hydroxypropyl methylcellulose and Soluplus) were revealed by differential scanning calorimetry and Fourier transform infrared spectroscopy. The hot-melt extruded solid dispersion was characterized by powder X-ray diffraction (XRD), scanning electron microscopy (SEM) and high-performance liquid chromatography (HPLC). The results of hot-stage polar microscopy indicated that DIF was dissolved in molten polymers at 160°C, much lower than the melting point of DIF (215°C). At this temperature, amorphous solid dispersions were successfully produced by HME, as confirmed by XRD and SEM. The related impurities in amorphous solid dispersions detected by HPLC were lower than 0.3%, indicating that thermal degradation was effectively minimized. The dissolution of DIF from amorphous solid dispersions was significantly enhanced as compared with the pure crystalline drug. This technique based on drug-polymer interactions to prepare chemically stable amorphous solid dispersions by HME provides an attractive opportunity for development of heat-sensitive drugs. © 2013 Royal Pharmaceutical Society.

  5. Identification of unknown impurity of azelaic acid in liposomal formulation assessed by HPLC-ELSD, GC-FID, and GC-MS.

    PubMed

    Han, Stanisław; Karłowicz-Bodalska, Katarzyna; Potaczek, Piotr; Wójcik, Adam; Ozimek, Lukasz; Szura, Dorota; Musiał, Witold

    2014-02-01

    The identification of new contaminants is critical in the development of new medicinal products. Many impurities, such as pentanedioic acid, hexanedioic acid, heptanedioic acid, octanedioic acid, decanedioic acid, undecanedioic acid, dodecanedioic acid, tridecanedioic acid, and tetradecanedioic acid, have been identified in samples of azelaic acid. The aim of this study was to identify impurities observed during the stability tests of a new liposomal dosage form of azelaic acid that is composed of phosphatidylcholine and a mixture of ethyl alcohol and water, using high-performance liquid chromatography with evaporative light-scattering detector (HPLC-ELSD), gas chromatography-flame ionisation detection (GC-FID), and gas chromatography-mass spectrometry (GC-MS) methods. During the research and development of a new liposomal formulation of azelaic acid, we developed a method for determining the contamination of azelaic acid using HPLC-ELSD. During our analytical tests, we identified a previously unknown impurity of a liposomal preparation of azelaic acid that appeared in the liposomal formulation of azelaic acid during preliminary stability studies. The procedure led to the conclusion that the impurity was caused by the reaction of azelaic acid with one of the excipients that was applied in the product. The impurity was finally identified as an ethyl monoester of azelaic acid. The identification procedure of this compound was carried out in a series of experiments comparing the chromatograms that were obtained via the following chromatographic methods: HPLC-ELSD, GC-FID, and GC-MS. The final identification of the compound was carried out by GC with MS.

  6. Analysis of Carbamate Pesticides: Validation of Semi-Volatile Analysis by HPLC-MS/MS by EPA Method MS666

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Owens, J; Koester, C

    The Environmental Protection Agency's (EPA) Region 5 Chicago Regional Laboratory (CRL) developed a method for analysis of aldicarb, bromadiolone, carbofuran, oxamyl, and methomyl in water by high performance liquid chromatography tandem mass spectrometry (HPLC-MS/MS), titled Method EPA MS666. This draft standard operating procedure (SOP) was distributed to multiple EPA laboratories and to Lawrence Livermore National Laboratory, which was tasked to serve as a reference laboratory for EPA's Environmental Reference Laboratory Network (ERLN) and to develop and validate analytical procedures. The primary objective of this study was to validate and verify the analytical procedures described in MS666 for analysis of carbamatemore » pesticides in aqueous samples. The gathered data from this validation study will be used to: (1) demonstrate analytical method performance; (2) generate quality control acceptance criteria; and (3) revise the SOP to provide a validated method that would be available for use during a homeland security event. The data contained in this report will be compiled, by EPA CRL, with data generated by other EPA Regional laboratories so that performance metrics of Method EPA MS666 can be determined.« less

  7. A new validated method for the simultaneous determination of benzocaine, propylparaben and benzyl alcohol in a bioadhesive gel by HPLC.

    PubMed

    Pérez-Lozano, P; García-Montoya, E; Orriols, A; Miñarro, M; Ticó, J R; Suñé-Negre, J M

    2005-10-04

    A new HPLC-RP method has been developed and validated for the simultaneous determination of benzocaine, two preservatives (propylparaben (nipasol) and benzyl alcohol) and degradation products of benzocaine in a semisolid pharmaceutical dosage form (benzocaine gel). The method uses a Nucleosil 120 C18 column and gradient elution. The mobile phase consisted of a mixture of methanol and glacial acetic acid (10%, v/v) at different proportion according to a time-schedule programme, pumped at a flow rate of 2.0 ml min(-1). The DAD detector was set at 258 nm. The validation study was carried out fulfilling the ICH guidelines in order to prove that the new analytical method, meets the reliability characteristics, and these characteristics showed the capacity of analytical method to keep, throughout the time, the fundamental criteria for validation: selectivity, linearity, precision, accuracy and sensitivity. The method was applied during the quality control of benzocaine gel in order to quantify the drug (benzocaine), preservatives and degraded products and proved to be suitable for rapid and reliable quality control method.

  8. A validated stability-indicating UPLC method for desloratadine and its impurities in pharmaceutical dosage forms.

    PubMed

    Rao, Dantu Durga; Satyanarayana, N V; Malleswara Reddy, A; Sait, Shakil S; Chakole, Dinesh; Mukkanti, K

    2010-02-05

    A novel stability-indicating gradient reverse phase ultra-performance liquid chromatographic (RP-UPLC) method was developed for the determination of purity of desloratadine in presence of its impurities and forced degradation products. The method was developed using Waters Aquity BEH C18 column with mobile phase containing a gradient mixture of solvents A and B. The eluted compounds were monitored at 280nm. The run time was 8min within which desloratadine and its five impurities were well separated. Desloratadine was subjected to the stress conditions of oxidative, acid, base, hydrolytic, thermal and photolytic degradation. Desloratadine was found to degrade significantly in oxidative and thermal stress conditions and stable in acid, base, hydrolytic and photolytic degradation conditions. The degradation products were well resolved from main peak and its impurities, thus proved the stability-indicating power of the method. The developed method was validated as per ICH guidelines with respect to specificity, linearity, limit of detection, limit of quantification, accuracy, precision and robustness. This method was also suitable for the assay determination of desloratadine in pharmaceutical dosage forms.

  9. Development and validation of a mass casualty conceptual model.

    PubMed

    Culley, Joan M; Effken, Judith A

    2010-03-01

    To develop and validate a conceptual model that provides a framework for the development and evaluation of information systems for mass casualty events. The model was designed based on extant literature and existing theoretical models. A purposeful sample of 18 experts validated the model. Open-ended questions, as well as a 7-point Likert scale, were used to measure expert consensus on the importance of each construct and its relationship in the model and the usefulness of the model to future research. Computer-mediated applications were used to facilitate a modified Delphi technique through which a panel of experts provided validation for the conceptual model. Rounds of questions continued until consensus was reached, as measured by an interquartile range (no more than 1 scale point for each item); stability (change in the distribution of responses less than 15% between rounds); and percent agreement (70% or greater) for indicator questions. Two rounds of the Delphi process were needed to satisfy the criteria for consensus or stability related to the constructs, relationships, and indicators in the model. The panel reached consensus or sufficient stability to retain all 10 constructs, 9 relationships, and 39 of 44 indicators. Experts viewed the model as useful (mean of 5.3 on a 7-point scale). Validation of the model provides the first step in understanding the context in which mass casualty events take place and identifying variables that impact outcomes of care. This study provides a foundation for understanding the complexity of mass casualty care, the roles that nurses play in mass casualty events, and factors that must be considered in designing and evaluating information-communication systems to support effective triage under these conditions.

  10. Separation and determination of impurities in paracetamol, codeine and pitophenone in the presence of fenpiverinium in combined suppository dosage form.

    PubMed

    Vojta, Jiří; Hanzlík, Pavel; Jedlička, Aleš; Coufal, Pavel

    2015-01-01

    A new HPLC method for separation and determination of impurities in paracetamol, codeine phosphate hemihydrate and pitophenone hydrochloride in the presence of fenpiverinium bromide in combined suppository dosage form was developed and validated. The separation of paracetamol and its impurities 4-aminophenol, 4-nitrophenol, 4-chloracetanilid; codeine and its impurities methylcodeine, morphine, codeine dimer and 10-hydroxycodeine; pitophenone and its impurities 2-[4-[2-(1-piperidinyl)ethoxy]benzoyl] benzoic acid, 2-[4-[2-(1-piperidinyl)ethoxy]benzoyl]benzoic acid 2-(1-piperidinyl)-ethyl ester, methyl ester of 2-(4-hydroxybenzoyl) benzoic acid and fenpiverinium was achieved by using ion-pair reversed phase liquid chromatography with UV detection. Validation parameters such as the precision, accuracy, linearity, limit of detection (LOD), limit of quantification (LOQ) and robustness were verified for all the mentioned impurities of codeine phosphate hemihydrate and 4-aminophenol and 2-[4-[2-(1-piperidinyl)ethoxy]benzoyl] benzoic acid as the main degradation products of paracetamol and pitophenone hydrochloride, respectively. The described method was found to be useful for analysis of the stability samples and therefore suitable for routine purity testing of the drug product. Copyright © 2014 Elsevier B.V. All rights reserved.

  11. A novel liquid chromatography/tandem mass spectrometry (LC-MS/MS) based bioanalytical method for quantification of ethyl esters of Eicosapentaenoic acid (EPA) and Docosahexaenoic acid (DHA) and its application in pharmacokinetic study.

    PubMed

    Viswanathan, Sekarbabu; Verma, P R P; Ganesan, Muniyandithevar; Manivannan, Jeganathan

    2017-07-15

    Omega-3 fatty acids are clinically useful and the two marine omega-3 fatty acids eicosapentaenoic acid (EPA) and docosahexaenoic acid (DHA) are prevalent in fish and fish oils. Omega-3 fatty acid formulations should undergo a rigorous regulatory step in order to obtain United States Food and Drug Administration (USFDA) approval as prescription drug. In connection with that, despite quantifying EPA and DHA fatty acids, there is a need for quantifying the level of ethyl esters of them in biological samples. In this study, we make use of reverse phase high performance liquid chromatography coupled with mass spectrometry (RP-HPLC-MS)technique for the method development. Here, we have developed a novel multiple reaction monitoring method along with optimized parameters for quantification of EPA and DHA as ethyl esters. Additionally, we attempted to validate the bio-analytical method by conducting the sensitivity, selectivity, precision accuracy batch, carryover test and matrix stability experiments. Furthermore, we also implemented our validated method for evaluation of pharmacokinetics of omega fatty acid ethyl ester formulations. Copyright © 2017 Elsevier B.V. All rights reserved.

  12. Additional Evidence for the Reliability and Validity of the Student Risk Screening Scale at the High School Level: A Replication and Extension

    ERIC Educational Resources Information Center

    Lane, Kathleen Lynne; Oakes, Wendy P.; Ennis, Robin Parks; Cox, Meredith Lucille; Schatschneider, Christopher; Lambert, Warren

    2013-01-01

    This study reports findings from a validation study of the Student Risk Screening Scale for use with 9th- through 12th-grade students (N = 1854) attending a rural fringe school. Results indicated high internal consistency, test-retest stability, and inter-rater reliability. Predictive validity was established across two academic years, with Spring…

  13. Isocratic RP-HPLC method for rutin determination in solid oral dosage forms.

    PubMed

    Kuntić, Vesna; Pejić, Natasa; Ivković, Branka; Vujić, Zorica; Ilić, Katarina; Mićić, Svetlana; Vukojević, Vladana

    2007-01-17

    A rapid and sensitive assay for quantitative determination of rutin in oral dosage forms based on isocratic reversed phase high performance liquid chromatography (RP-HPLC) was developed and validated. Using a C(18) reverse-phase analytical column, the following conditions were chosen as optimal: mobile phase methanol-water 1:1 (v/v), pH 2.8 (adjusted with phosphoric acid), flow rate=1 mL min(-1) and temperature T=40.0 degrees C. Linearity was observed in the concentration range 8-120 microg mL(-1) with a correlation coefficient of 0.99982 and the limit of detection (LOD)=2.6 microg mL(-1), and limit of quantification (LOQ)=8.0 microg mL(-1). Intra- and inter-day precision were within acceptable limits. Robustness test indicated that the mobile phase composition and pH influence mainly the separation. The proposed method allowed direct determination of rutin in pharmaceutical dosage forms in the presence of excipients, but is not suitable for preparations where compounds structurally/chemically related to rutin may be present.

  14. Development of a sensitive high-performance liquid chromatographic method with simple extraction for simultaneous determination of huperzine A and huperzine B in the species containing lycopodium alkaloids.

    PubMed

    Zhang, Yanqing; Xie, Junbo; Chen, Wen-Qian; Zhou, Tian-Yan; Lu, Wei

    2009-01-01

    A sensitive HPLC method with simple extraction was developed for simultaneous determination of huperzine A (HupA) and huperzine B (HupB) in Huperzia serrata, H. crispata, H. miyoshiana, and Lycopodiastrum casuarinoides. In order to avoid conventional multiple-step and time-consuming sample preparation methods, direct reflux extraction with alkaline chloroform was adopted. The quantitative determination was conducted by reversed-phase HPLC with a photodiode array detector set at 308 nm. Separation was performed on a Luna C18 column (250 x 4.6 mm id, 5 microm) with methanol-0.2% aqueous acetic acid (18 + 82, v/v) mobile phase. The method was validated for accuracy, reproducibility, precision, and limits of detection and quantification. Quantification of the two active compounds in the samples was performed by this newly developed method, and the content of HupA and HupB varied substantially among four different species. The satisfactory results indicated that the developed method can readily be utilized for quality control of the species of Huperziaceae and Lycopodiaceae containing the two compounds.

  15. Activity study of biogenic spherical silver nanoparticles towards microbes and oxidants

    NASA Astrophysics Data System (ADS)

    Hoskote Anand, Kiran Kumar; Mandal, Badal Kumar

    2015-01-01

    The eco-friendly approach for the green synthesis of silver nanoparticles (SNP) using Terminalia bellirica (T. bellirica) fruit extract is reported herein. Initially formation of SNP was noticed through visual color change from yellow to reddish brown and further analyzed by surface plasmonic resonance (SPR) band at 429 nm using UV-Vis spectroscopy. Identification of different polyphenols present in T. bellirica extract was done using High Pressure Liquid Chromatography (HPLC). Aqueous T. bellirica extract contains high amount of gallic acid which is major secondary metabolite responsible for the reduction and stabilization process. It was established by analyses of extracts before and after reduction using HPLC. Formation of spherical SNP was characterized by Transmission Electron Microscopy (TEM) analysis. X-ray Diffraction (XRD) study revealed crystalline nature of SNP. Presence of different functional groups on the surface of SNP was evidenced by Fourier Transform Infrared Spectroscopy (FTIR) study. A plausible mechanism of reduction and stabilization processes involved in the synthesis of stable SNP was also explained based on HPLC and FTIR data. In addition, the synthesized SNP was tested for antibacterial and antioxidant activities. SNP showed good antimicrobial activity against both gram positive (S. aureus) and gram negative (E. coli) bacteria. It also showed good antioxidant activity compared to ascorbic acid as standard antioxidant by using standard DPPH method.

  16. Comparative study of fourteen alkaloids from Uncaria rhynchophylla hooks and leaves using HPLC-diode array detection-atmospheric pressure chemical ionization/MS method.

    PubMed

    Qu, Jialin; Gong, Tianxing; Ma, Bin; Zhang, Lin; Kano, Yoshihiro; Yuan, Dan

    2012-01-01

    The purpose of the study is to compare alkaloid profile of Uncaria rhynchophylla hooks and leaves. Ten oxindole alkaloids and four glycosidic indole alkaloids were identified using HPLC-diode array detection (DAD) or LC-atmospheric pressure chemical ionization (APCI)-MS method, and a HPLC-UV method for simultaneous quantification of major alkaloids was validated. The hooks are characterized by high levels of four oxindole alkaloids rhynchophylline (R), isorhynchophylline (IR), corynoxeine (C) and isocorynoxeine (IC), while the leaves contained high level of two glycosidic indole alkaloids vincoside lactam (VL) and strictosidine (S). The presented methods have proven its usefulness in chemical characterization of U. rhynchophylla hooks and leaves.

  17. Poly(alkylmethylsiloxanes) thermally immobilized on silica as stationary phases for high-performance liquid chromatography.

    PubMed

    Bottoli, Carla B G; Chaudhry, Zahra F; Fonseca, Dania A; Collins, Kenneth E; Collins, Carol H

    2002-03-01

    Poly(methyloctylsiloxane) (PMOS) and poly(methyloctadecylsiloxane) (PMODS) were sorbed onto porous HPLC silica and thermally immobilized, in the absence of radical initiators, at temperatures in the range of 80 to 180 degrees C. Following extraction of non-immobilized polymer the materials were packed into columns and their chromatographic properties evaluated. The shorter chain (PMOS) stationary phase showed good HPLC characteristics after thermal immobilizations up to 120 degrees C while the longer chain (PMODS) phase gave satisfactory HPLC phases following thermal immobilizations at 80 and 100 degrees C. Stability evaluation for the PMOS and PMODS columns immobilized at 100 degrees C required 250 ml of pH 8.5 mobile phase at 60 degrees C to significantly decrease efficiency, suggesting a long useful life time at neutral pH and ambient temperature.

  18. Antiinflammatory effects of Viola tricolor gel in a model of sunburn in rats and the gel stability study.

    PubMed

    Piana, Mariana; Silva, Mariane Arnoldi; Trevisan, Gabriela; de Brum, Thiele Faccim; Silva, Cássia Regina; Boligon, Aline Augusti; Oliveira, Sara Marchesan; Zadra, Marina; Hoffmeister, Carin; Rossato, Mateus Fortes; Tonello, Raquel; Laporta, Luciane Varini; de Freitas, Robson Borba; Belke, Bianca Vargas; Jesus, Roberta da Silva; Ferreira, Juliano; Athayde, Margareth Linde

    2013-11-25

    Viola tricolor, popularly known as heartsease has been empirically used in several skin disorders, including burns. The objective of this study was investigate the antinociceptive and antiinflammatory effect of a gel containing extract of Viola tricolor flowers on thermal burn induced by UVB irradiation and to perform gel stability study. The antinociceptive and antiinflammatory effect were evaluated by static and dynamic mechanical allodynia model, paw edema, and neutrophilic cell infiltration. Metabolites compounds were quantified by HPLC. The gel stability study was performed analyzing organoleptical aspects, besides pH, viscosity, and quantification of rutin by HPLC. In the results were evidenced changes in threshold in statical and dynamic mechanical allodynia (I(max)=100 ± 10% and 49 ± 10%, respectively), paw edema (I(max)=61 ± 6%), and myeloperoxidase activity (I(max)=89 ± 5%). Such effects may be attributed, in part, to rutin, salicylic and chlorogenic acids, and others compounds found in this species. No important changes were detected in the stability study, in all aspects analyzed in temperature below 25 °C. These findings suggest that Viola tricolor gel has an antinociceptive and antiinflammatory effect in the ultraviolet-B-induced burn, since maintain the temperature below 25 °C. © 2013 Elsevier Ireland Ltd. All rights reserved.

  19. Development and validation of an HPLC-MS/MS method for the detection of ketamine in Calliphora vomitoria (L.) (Diptera: Calliphoridae).

    PubMed

    Magni, Paola A; Pazzi, Marco; Droghi, Jessica; Vincenti, Marco; Dadour, Ian R

    2018-05-03

    Entomotoxicology is a branch of forensic entomology that studies the detection of drugs or other toxic substances from insects developing on the decomposing tissues of a human corpse or animal carcass. Entomotoxicology also investigates the effects of these substances on insect development, survival and morphology to provide an estimation of the minimum time since death. Ketamine is a medication mainly used for starting and maintaining anesthesia. In recent years ketamine has also been used as a recreational drug, and occasionally as a sedating drug to facilitate sexual assault. In both activities, it has resulted in several deaths. Furthermore, ketamine has been also implicated in suspicious deaths of animals. The present research describes for the first time the development and validation of an analytical method suited to detect ketamine in larvae, pupae, empty puparia, and adults of Calliphora vomitoria L. (Diptera: Calliphoridae), using liquid chromatography-tandem mass spectrometry (HPLC-MS/MS). This research also considers the effects of ketamine on the survival, developmental rate and morphology (length and width of larvae and pupae) of C. vomitoria. The larvae were reared on liver substrates homogeneously spiked with ketamine concentrations consistent with those found in humans after recreational use (300 ng/mg) or allegedly indicated as capable of causing death in either humans or animals (600 ng/mg). The results demonstrated that (a) HPLC-MS/MS method is applicable to ketamine detection in C. vomitoria immatures, not adults; (b) the presence of ketamine at either concentration in the food substrate significantly delays the developmental time to pupal and adult instar; (d) the survival of C. vomitoria is negatively affected by the presence of ketamine in the substrate; (e) the length and width of larvae and pupae exposed to either ketamine concentration were significantly larger than the control samples. Copyright © 2018. Published by Elsevier Ltd.

  20. Simultaneous, stability indicating, HPLC-DAD determination of guaifenesin and methyl and propyl-parabens in cough syrup.

    PubMed

    Grosa, Giorgio; Del Grosso, Erika; Russo, Roberta; Allegrone, Gianna

    2006-06-07

    A stability indicating high performance liquid chromatography procedure has been developed for the simultaneous determination of guaifenesin (GUA), methyl p-hydroxybenzoate (MHB) and propyl p-hydroxybenzoate (PHB) in a commercial cough syrup dosage form. The method was specific and stability indicating as chromatographic conditions were selected to provide adequate separation of GUA, MHB and PHB from the putative degradation products guaiacol (GUAI) and p-hydroxybenzoic acid (HBA) as well as from excipients. The isocratic separation and quantitation were achieved within 17 min on a 150-mm column with an ether-linked phenyl stationary phase and a hydrophilic endcapping. The mobile phase was constituted of eluant A: aqueous phosphate buffer (pH 3.0, 10 mM)/acetonitrile 25/75 (v/v) and eluant B:methanol; the A:B ratio was 85:15 (v/v) with a flow rate 1 ml min-1 and detection of analytes at 254 and 276 nm. The method showed good linearity for the GUA-MHB-PHB mixture in the 95-285, 4-12, and 1-3 microg ml-1 ranges, respectively, being all the square of the correlation coefficients greater than 0.999. The interday R.S.D.s were 1.17, 1.14, and 0.91%, for GUA, MHB, and PHP, respectively. The method demonstrated also to be accurate; indeed the average recoveries, at 100% of the target assay concentration, were 100.5, 100.3, and 100.7% with relative standard deviations of 0.8, 0.7, and 0.4% for GUA, MHB, and PHB, respectively, from laboratory prepared samples. The applicability of the method was evaluated in commercial dosage form analysis as well as in stability studies.

  1. Stability Indicating HPLC Method for Simultaneous Determination of Mephenesin and Diclofenac Diethylamine

    PubMed Central

    Mulgund, S. V.; Phoujdar, M. S.; Londhe, S. V.; Mallade, P. S.; Kulkarni, T. S.; Deshpande, A. S.; Jain, K. S.

    2009-01-01

    A simple, specific, accurate and stability-indicating reversed phase high performance liquid chromatographic method was developed for the simultaneous determination of mephenesin and diclofenac diethylamine, using a Spheri-5-RP-18 column and a mobile phase composed of methanol: water (70:30, v/v), pH 3.0 adjusted with o-phosphoric acid. The retention times of mephenesin and diclofenac diethylamine were found to be 3.9 min and 14.5 min, respectively. Linearity was established for mephenesin and diclofenac diethylamine in the range of 50-300 μg/ml and 10-60 μg/ml, respectively. The percentage recoveries of mephenesin and diclofenac diethylamine were found to be in the range of 99.06-100.60% and 98.95-99.98%, respectively. Both the drugs were subjected to acid, alkali and neutral hydrolysis, oxidation, dry heat, photolytic and UV degradation. The degradation studies indicated, mephenesin to be susceptible to neutral hydrolysis, while diclofenac diethylamine showed degradation in acid, H2O2, photolytic and in presence of UV radiation. The degradation products of diclofenac diethylamine in acidic and photolytic conditions were well resolved from the pure drug with significant differences in their retention time values. This method can be successfully employed for simultaneous quantitative analysis of mephenesin and diclofenac diethylamine in bulk drugs and formulations. PMID:20177453

  2. Stability indicating HPLC method for simultaneous determination of mephenesin and diclofenac diethylamine.

    PubMed

    Mulgund, S V; Phoujdar, M S; Londhe, S V; Mallade, P S; Kulkarni, T S; Deshpande, A S; Jain, K S

    2009-01-01

    A simple, specific, accurate and stability-indicating reversed phase high performance liquid chromatographic method was developed for the simultaneous determination of mephenesin and diclofenac diethylamine, using a Spheri-5-RP-18 column and a mobile phase composed of methanol: water (70:30, v/v), pH 3.0 adjusted with o-phosphoric acid. The retention times of mephenesin and diclofenac diethylamine were found to be 3.9 min and 14.5 min, respectively. Linearity was established for mephenesin and diclofenac diethylamine in the range of 50-300 mug/ml and 10-60 mug/ml, respectively. The percentage recoveries of mephenesin and diclofenac diethylamine were found to be in the range of 99.06-100.60% and 98.95-99.98%, respectively. Both the drugs were subjected to acid, alkali and neutral hydrolysis, oxidation, dry heat, photolytic and UV degradation. The degradation studies indicated, mephenesin to be susceptible to neutral hydrolysis, while diclofenac diethylamine showed degradation in acid, H(2)O(2), photolytic and in presence of UV radiation. The degradation products of diclofenac diethylamine in acidic and photolytic conditions were well resolved from the pure drug with significant differences in their retention time values. This method can be successfully employed for simultaneous quantitative analysis of mephenesin and diclofenac diethylamine in bulk drugs and formulations.

  3. Development and validation of a liquid chromatography-tandem mass spectrometry method for the determination of pyridostigmine bromide from guinea pig plasma.

    PubMed

    Needham, Shane R; Ye, Binying; Smith, J Richard; Korte, William D

    2003-11-05

    An HPLC/MS/MS method was validated for the low level analysis of pyridostigmine bromide (PB) from guinea pig plasma. An advantage of this strong-cation exchange HPLC/MS/MS method was the enhancement of the ESI-MS signal by providing good retention and good peak shape of PB with a mobile phase of 70% acetonitrile. In addition, the use of 70% acetonitrile in the mobile phase allowed the direct injection of the supernant from the protein precipitated extracted sample. The assay was linear from the range of 0.1 to 50 ng/ml using only 25 microl of sample. The precision and accuracy of the assay was better than 9.1 and 113%, respectively.

  4. Study on the stability control strategy of Triphala solution based on the balance of physical stability and chemical stabilities.

    PubMed

    Huang, Hao-Zhou; Zhao, Sheng-Yu; Ke, Xiu-Mei; Lin, Jun-Zhi; Huang, Shu-Sen; Xu, Run-Chun; Ma, Hong-Yan; Zhang, Yi; Han, Li; Zhang, Ding-Kun

    2018-06-04

    Triphala is a well-known prescription in Indian Ayurveda and TCM medicine for its great effect on gingivitis and hyperlipidemia. However, its solution is unstable for the containing of excessive polyphenol, leading to the production of sediment in the short term and the decrease of efficacy. Based on the analysis of sediment formation, a novel control strategy is proposed. To conduct the analysis, the sediment formation was recorded for a consecutive five days. The changes in the composition of the supernatant and the sediment were studied by the HPLC profile analysis. The main components of the sediment were identified as corilagin, ellagic acid and gallic acid, and the amount of ellagic acid sediment increased with the storage time. Then, with a series of pH status adjustments of the Triphala solution, the physical and chemical stabilities were acquired by Turbiscan and HPLC respectively. The results showed that as the pH value increased, so did the physical stability, but the particle size and TSI of the association decreased. While the fingerprint of chemical profile similarity decreased, so did the chemical stability. Combining physical and chemical stability parameters, an equilibrium point was found out. When the pH value was adjusted to 5.0, both the physical and chemical stabilities were better: the verification test showed that the sedimentation inhibition rates on the 3rd, 5th,10th and15th days were 41%, 55%, 41%, and 23%, respectively. This manuscript provided a new control strategy that will pique pharmaceutical and food development engineers' interest and trigger research ideas controlling the quality of decoction. Copyright © 2018 Elsevier B.V. All rights reserved.

  5. Development and Validation of Stability Indicating Spectroscopic Method for Content Analysis of Ceftriaxone Sodium in Pharmaceuticals

    PubMed Central

    Ethiraj, Revathi; Thiruvengadam, Ethiraj; Sampath, Venkattapuram Saravanan; Vahid, Abdul; Raj, Jithin

    2014-01-01

    A simple, selective, and stability indicating spectroscopic method has been selected and validated for the assay of ceftriaxone sodium in the powder for injection dosage forms. Proposed method is based on the measurement of absorbance of ceftriaxone sodium in aqueous medium at 241 nm. The method obeys Beer's law in the range of 5–50 μg/mL with correlation coefficient of 0.9983. Apparent molar absorptivity and Sandell's sensitivity were found to be 2.046 × 103 L mol−1 cm−1 and 0.02732 μg/cm2/0.001 absorbance units. This study indicated that ceftriaxone sodium was degraded in acid medium and also underwent oxidative degradation. Percent relative standard deviation associated with all the validation parameters was less than 2, showing compliance with acceptance criteria of Q2 (R1), International Conference on Harmonization (2005) guidelines. Then the proposed method was successfully applied to the determination of ceftriaxone sodium in sterile preparation and results were comparable with reported methods. PMID:27355020

  6. Reverse phase HPLC method for detection and quantification of lupin seed γ-conglutin.

    PubMed

    Mane, Sharmilee; Bringans, Scott; Johnson, Stuart; Pareek, Vishnu; Utikar, Ranjeet

    2017-09-15

    A simple, selective and accurate reverse phase HPLC method was developed for detection and quantitation of γ-conglutin from lupin seed extract. A linear gradient of water and acetonitrile containing trifluoroacetic acid (TFA) on a reverse phase column (Agilent Zorbax 300SB C-18), with a flow rate of 0.8ml/min was able to produce a sharp and symmetric peak of γ-conglutin with a retention time at 29.16min. The identity of γ-conglutin in the peak was confirmed by mass spectrometry (MS/MS identification) and sodium dodecyl sulphate polyacrylamide gel electrophoresis (SDS-PAGE) analysis. The data obtained from MS/MS analysis was matched against the specified database to obtain the exact match for the protein of interest. The proposed method was validated in terms of specificity, linearity, sensitivity, precision, recovery and accuracy. The analytical parameters revealed that the validated method was capable of selectively performing a good chromatographic separation of γ-conglutin from the lupin seed extract with no interference of the matrix. The detection and quantitation limit of γ-conglutin were found to be 2.68μg/ml and 8.12μg/ml respectively. The accuracy (precision and recovery) analysis of the method was conducted under repeatable conditions on different days. Intra-day and inter-day precision values less than 0.5% and recovery greater than 97% indicated high precision and accuracy of the method for analysis of γ-conglutin. The method validation findings were reproducible and can be successfully applied for routine analysis of γ-conglutin from lupin seed extract. Copyright © 2017 Elsevier B.V. All rights reserved.

  7. Ingredient Consistency of Commercially Available Polyphenol and Tocopherol Nutraceuticals

    PubMed Central

    Remsberg, Connie M.; Good, Renee L.; Davies, Neal M.

    2010-01-01

    Label claims of vitamin E succinate and polyphenolic nutraceuticals are assessed. A validated HPLC method was utilized to assess vitamin E succinate products. Three novel LC/MS methods were used to assess the polyphenols, pterostilbene, phloretin, and myricetin, in dietary supplements. The amount of vitamin E succinate varied from 0-130% of the stated label content with two products containing vitamin E acetate rather than vitamin E succinate. Expected polyphenols were found in 7 of the 8 supplement products. None of the polyphenol supplements contained content within 100-120% of label claims. The present study indicates a lack of uniformity in nutraceutical products. PMID:27721342

  8. Validation of sparse sampling strategies to estimate cyclosporine A area under the concentration-time curve using either a specific radioimmunoassay or high-performance liquid chromatography method.

    PubMed

    Koristkova, Blanka; Grundmann, Milan; Brozmanova, Hana; Perinova, Ilona; Safarcik, Kristian

    2010-10-01

    Area under the concentration-time curve (AUC) has been advocated as a better parameter to monitor cyclosporine A than trough concentrations. Up to now, more than 100 equations to estimate AUC using a limited sampling strategy have been published, but not all have been validated. Eight equations for AUC0-12h and two for AUC0-8h were validated. Concentrations of cyclosporine A were analyzed by high-performance liquid chromatography (HPLC) and a specific radioimmunoassay (RIA) method. Forty male renal transplant patients were included in the study. Blood samples were taken predose and at 0.5, 1, 1.5, 2, 3, 5, 8, and 12 hours after the morning dose when the patient was in steady state. The percentage prediction error (%pe) was used for an assessment of the performance of the equations. Mean %pe less than ± 15% and absolute %pe less than 30% in 95% of predictions were considered to be acceptable. Other possibilities such as %pe less than 25%, 20%, and 15% were also tested. Eight equations for AUC0-12h met the requirements using both assays, six in the HPLC set only and four in the RIA set only. The highest precision was obtained with AUC0-12h = 123.792 + 1.165*C1h + 3.021*C3h + 7.33*C8h proposed by de Mattos et al. The mean %pe was 1% ± 8% (-16 to 19) for HPLC (values given as mean ± standard deviation [range]) and -1 ± 5 (-17 to 10) for RIA. Mean absolute %pe was 7 ± 5 (0.0 to 19) for HPLC and 4 ± 4 (0.0 to 17) for RIA. For clinical use, the most suitable equation was AUC0-12h = 363.078 + 8.77*C1h + 3.07*C3h proposed by Wacke et al, which produced the second lowest %pe and used two sampling points in the period of 1 to 3 hours after dose. The mean %pe was -7 ± 10 (-25 to 25) for HPLC and 2.3 ± 6 (-10 to 17) for RIA. Mean absolute %pe was 10 ± 7 (0.4 to 25) for HPLC and 5 ± 4 (0.0 to 17) for RIA. The equation: AUC0-8h = 55.37 + 2.89*C0h + 1.08*C1h0.9*C2h + 2.23*C3h proposed by Foradori et al met the criteria with 95% of prediction with absolute %pe less than 15% in the HPLC set and 10% in the RIA set. The validation of equations is of major importance for prediction precision, whereas the analytical method for limited sampling strategy proposals had no influence. Because of the wide interassay variability, it is also important to know which analytical method was used for AUC calculation when interpreting the results.

  9. Test-retest stability of the Task and Ego Orientation Questionnaire.

    PubMed

    Lane, Andrew M; Nevill, Alan M; Bowes, Neal; Fox, Kenneth R

    2005-09-01

    Establishing stability, defined as observing minimal measurement error in a test-retest assessment, is vital to validating psychometric tools. Correlational methods, such as Pearson product-moment, intraclass, and kappa are tests of association or consistency, whereas stability or reproducibility (regarded here as synonymous) assesses the agreement between test-retest scores. Indexes of reproducibility using the Task and Ego Orientation in Sport Questionnaire (TEOSQ; Duda & Nicholls, 1992) were investigated using correlational (Pearson product-moment, intraclass, and kappa) methods, repeated measures multivariate analysis of variance, and calculating the proportion of agreement within a referent value of +/-1 as suggested by Nevill, Lane, Kilgour, Bowes, and Whyte (2001). Two hundred thirteen soccer players completed the TEOSQ on two occasions, 1 week apart. Correlation analyses indicated a stronger test-retest correlation for the Ego subscale than the Task subscale. Multivariate analysis of variance indicated stability for ego items but with significant increases in four task items. The proportion of test-retest agreement scores indicated that all ego items reported relatively poor stability statistics with test-retest scores within a range of +/-1, ranging from 82.7-86.9%. By contrast, all task items showed test-retest difference scores ranging from 92.5-99%, although further analysis indicated that four task subscale items increased significantly. Findings illustrated that correlational methods (Pearson product-moment, intraclass, and kappa) are influenced by the range in scores, and calculating the proportion of agreement of test-retest differences with a referent value of +/-1 could provide additional insight into the stability of the questionnaire. It is suggested that the item-by-item proportion of agreement method proposed by Nevill et al. (2001) should be used to supplement existing methods and could be especially helpful in identifying rogue items in the initial stages of psychometric questionnaire validation.

  10. Validated method for the analysis of goji berry, a rich source of zeaxanthin dipalmitate.

    PubMed

    Karioti, Anastasia; Bergonzi, Maria Camilla; Vincieri, Franco F; Bilia, Anna Rita

    2014-12-31

    In the present study an HPLC-DAD method was developed for the determination of the main carotenoid, zeaxanthin dipalmitate, in the fruits of Lycium barbarum. The aim was to develop and optimize an extraction protocol to allow fast, exhaustive, and repeatable extraction, suitable for labile carotenoid content. Use of liquid N2 allowed the grinding of the fruit. A step of ultrasonication with water removed efficiently the polysaccharides and enabled the exhaustive extraction of carotenoids by hexane/acetone 50:50. The assay was fast and simple and permitted the quality control of a large number of commercial samples including fruits, juices, and a jam. The HPLC method was validated according to ICH guidelines and satisfied the requirements. Finally, the overall method was validated for precision (% RSD ranging between 3.81 and 4.13) and accuracy at three concentration levels. The recovery was between 94 and 107% with RSD values <2%, within the acceptable limits, especially if the difficulty of the matrix is taken into consideration.

  11. Development and validation of a high performance liquid chromatographic method for simultaneous determination of vitamins A and D3 in fluid milk products.

    PubMed

    Chen, Yang; Reddy, Ravinder M; Li, Wenjing; Yettlla, Ramesh R; Lopez, Salvador; Woodman, Michael

    2015-01-01

    An HPLC method for simultaneous determination of vitamins A and D3 in fluid milk was developed and validated. Saponification and extraction conditions were studied for optimum recovery and simplicity. An RP HPLC system equipped with a C18 column and diode array detector was used for quantitation. The method was subjected to a single-laboratory validation using skim, 2% fat, and whole milk samples at concentrations of 50, 100, and 200% of the recommended fortification levels for vitamins A and D3 for Grade "A" fluid milk. The method quantitation limits for vitamins A and D3 were 0.0072 and 0.0026 μg/mL, respectively. Average recoveries between 94 and 110% and SD values ranging from 2.7 to 6.9% were obtained for both vitamins A and D3. The accuracy of the method was evaluated using a National Institute of Standards and Technology standard reference material (1849a) and proficiency test samples.

  12. Validation of quantitative method for azoxystrobin residues in green beans and peas.

    PubMed

    Abdelraheem, Ehab M H; Hassan, Sayed M; Arief, Mohamed M H; Mohammad, Somaia G

    2015-09-01

    This study presents a method validation for extraction and quantitative analysis of azoxystrobin residues in green beans and peas using HPLC-UV and the results confirmed by GC-MS. The employed method involved initial extraction with acetonitrile after the addition of salts (magnesium sulfate and sodium chloride), followed by a cleanup step by activated neutral carbon. Validation parameters; linearity, matrix effect, LOQ, specificity, trueness and repeatability precision were attained. The spiking levels for the trueness and the precision experiments were (0.1, 0.5, 3 mg/kg). For HPLC-UV analysis, mean recoveries ranged between 83.69% to 91.58% and 81.99% to 107.85% for green beans and peas, respectively. For GC-MS analysis, mean recoveries ranged from 76.29% to 94.56% and 80.77% to 100.91% for green beans and peas, respectively. According to these results, the method has been proven to be efficient for extraction and determination of azoxystrobin residues in green beans and peas. Copyright © 2015 Elsevier Ltd. All rights reserved.

  13. Analysis of pharmaceutical impurities using multi-heartcutting 2D LC coupled with UV-charged aerosol MS detection.

    PubMed

    Zhang, Kelly; Li, Yi; Tsang, Midco; Chetwyn, Nik P

    2013-09-01

    To overcome challenges in HPLC impurity analysis of pharmaceuticals, we developed an automated online multi-heartcutting 2D HPLC system with hyphenated UV-charged aerosol MS detection. The first dimension has a primary column and the second dimension has six orthogonal columns to enhance flexibility and selectivity. The two dimensions were interfaced by a pair of switching valves equipped with six trapping loops that allow multi-heartcutting of peaks of interest in the first dimension and also allow "peak parking." The hyphenated UV-charged aerosol MS detection provides comprehensive detection for compounds with and without UV chromophores, organics, and inorganics. It also provides structural information for impurity identification. A hidden degradation product that co-eluted with the drug main peak was revealed by RP × RP separation and thus enabled the stability-indicating method development. A poorly retained polar component with no UV chromophores was analyzed by RP × hydrophilic interaction liquid chromatography separation with charged aerosol detection. Furthermore, using this system, the structures of low-level impurities separated by a method using nonvolatile phosphate buffer were identified and tracked by MS in the second dimension. © 2013 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  14. Biodistribution and Stability Studies of [18F]Fluoroethylrhodamine B, a Potential PET Myocardial Perfusion Agent

    PubMed Central

    Gottumukkala, Vijay; Heinrich, Tobias K.; Baker, Amanda; Dunning, Patricia; Fahey, Frederick H; Treves, S. Ted; Packard, Alan B.

    2010-01-01

    Introduction Fluorine-18-labeled rhodamine B was developed as a potential PET tracer for the evaluation of myocardial perfusion, but preliminary studies in mice showed no accumulation in the heart suggesting that it was rapidly hydrolyzed in vivo in mice. A study was, therefore, undertaken to further evaluate this hypothesis. Methods [18F]Fluoroethylrhodamine B was equilibrated for 2 h at 37 °C in human, rat and mouse serum and in PBS. Samples were removed periodically and assayed by HPLC. Based on the results of the stability study, microPET imaging and a biodistribution study were carried out in rats. Results In vitro stability studies demonstrated that [18F]fluoroethylrhodamine B much more stable in rat and human sera than in mouse serum. After 2 h, the compound was >80% intact in rat serum but <30% intact in mouse serum. The microPET imaging and biodistribution studies in rats confirmed this result showing high and persistent tracer accumulation in the myocardium compared with the absence of uptake by the myocardium in mice thereby validating our original hypothesis that 18F-labeled rhodamines should accumulate in the heart. Conclusions [18F]Fluoroethyl rhodamine B is more stable in rat and human sera than it is in mouse serum. This improved stability is demonstrated by the high uptake of the tracer in the rat heart in comparison to the absence of visible uptake in the mouse heart. These observations suggest that 18F-labeled rhodamines are promising candidates for more extensive evaluation as PET tracers for the evaluation of myocardial perfusion. PMID:20346876

  15. Skin carotenoids as biomarker for vegetable and fruit intake: Validation of the reflection-spectroscopy based “Veggie Meter”

    USDA-ARS?s Scientific Manuscript database

    Skin is a relatively stable storage medium for carotenoids; non-invasive optical measurements of carotenoids in this tissue via Resonance Raman spectroscopy (RRS) serve as a non-invasive biomarker for fruit and vegetable (F/V) intake. The RRS method has been validated with HPLC-based measurements of...

  16. Methods and applications of HPLC-AMS (WBio 5)

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Bucholz, B A; Clifford, A J; Duecker, S R

    Pharmacokinetics of physiologic doses of nutrients, pesticides, and herbicides can easily be traced in humans using a {sup 14}C-labelled compound. Basic kinetics can be monitored in blood or urine by measuring the elevation in the {sup 14}C content above the control predose tissue and converting to equivalents of the parent compound. High Performance Liquid Chromatography (HPLC) is an excellent method for the chemical separation of complex mixtures whose profiles afford estimation of biochemical pathways of metabolism. Compounds elute from the HPLC systems with characteristic retention times and can be collected in fractions that can then be graphitized for AMS measurement.more » Unknowns are identified by coelution with known standards and chemical tests that reveal functional groupings. Metabolites are quantified with the {sup 14}C signal. Thoroughly accounting for the carbon inventory in the LC solvents, ion-pairing agents, samples, and carriers adds some complexity to the analysis. In most cases the total carbon inventory is dominated by carrier. Baseline background and stability need to be carefully monitored. Limits of quantitation near 10 amol of {sup 14}C per HPLC fraction are typically achieved. Baselines are maintained by limiting injected {sup 14}C activity <0.17 Bq (4.5 pCi) on the HPLC column.« less

  17. Analytical Method Development and Validation for the Simultaneous Estimation of Abacavir and Lamivudine by Reversed-phase High-performance Liquid Chromatography in Bulk and Tablet Dosage Forms.

    PubMed

    Raees Ahmad, Sufiyan Ahmad; Patil, Lalit; Mohammed Usman, Mohammed Rageeb; Imran, Mohammad; Akhtar, Rashid

    2018-01-01

    A simple rapid, accurate, precise, and reproducible validated reverse phase high performance liquid chromatography (HPLC) method was developed for the determination of Abacavir (ABAC) and Lamivudine (LAMI) in bulk and tablet dosage forms. The quantification was carried out using Symmetry Premsil C18 (250 mm × 4.6 mm, 5 μm) column run in isocratic way using mobile phase comprising methanol: water (0.05% orthophosphoric acid with pH 3) 83:17 v/v and a detection wavelength of 245 nm and injection volume of 20 μl, with a flow rate of 1 ml/min. In the developed method, the retention times of ABAC and LAMI were found to be 3.5 min and 7.4 min, respectively. The method was validated in terms of linearity, precision, accuracy, limits of detection, limits of quantitation, and robustness in accordance with the International Conference on Harmonization guidelines. The assay of the proposed method was found to be 99% - 101%. The recovery studies were also carried out and mean % recovery was found to be 99% - 101%. The % relative standard deviation from reproducibility was found to be <2%. The proposed method was statistically evaluated and can be applied for routine quality control analysis of ABAC and LAMI in bulk and in tablet dosage form. Attempts were made to develop RP-HPLC method for simultaneous estimation of Abacavir and Lamivudine for the RP-HPLC method. The developed method was validated according to the ICH guidelines. The linearity, precision, range, robustness were within the limits as specified by the ICH guidelines. Hence the method was found to be simple, accurate, precise, economic and reproducible. So the proposed methods can be used for the routine quality control analysis of Abacavir and Lamivudine in bulk drug as well as in formulations. Abbreviations Used: HPLC: High-performance liquid chromatography, UV: Ultraviolet, ICH: International Conference on Harmonization, ABAC: Abacavir, LAMI: Lamivudine, HIV: Human immunodeficiency virus, AIDS: Acquired immunodeficiency syndrome, NRTI: Nucleoside reverse transcriptase inhibitors, ARV: Antiretroviral, RSD: Relative standard deviation, RT: Retention time, SD: Standard deviation.

  18. Quantification of tamoxifen DNA adducts using on-line sample preparation and HPLC-electrospray ionization tandem mass spectrometry.

    PubMed

    Gamboa da Costa, Gonçalo; Marques, M Matilde; Beland, Frederick A; Freeman, James P; Churchwell, Mona I; Doerge, Daniel R

    2003-03-01

    The nonsteroidal antiestrogen tamoxifen is used as an adjuvant chemotherapeutic agent for the treatment of all stages of hormone-dependent breast cancer and more recently as a chemopreventive agent in women with elevated risk of developing the disease. While clearly beneficial for the treatment of breast cancer, tamoxifen has been reported to increase the risk of endometrial cancer in women. Furthermore, it has been shown to be hepatocarcinogenic in rats. Tamoxifen is clearly genotoxic in rat liver, as indicated by the formation of DNA adducts; the occurrence of tamoxifen DNA adducts in human endometrial tissue is more controversial. The detection and quantitation of tamoxifen DNA adducts have relied primarily upon (32)P-postlabeling, with other techniques, such as immunoassays and accelerator mass spectrometry, being used to a much lesser extent. To expand the range of available analytical methodologies for quantifying tamoxifen DNA adducts, we have developed an assay using on-line sample preparation, coupled with HPLC and electrospray ionization tandem mass spectrometry (ES-MS/MS). alpha-Acetoxytamoxifen was reacted with salmon testis DNA at ratios between 0.1 ng and 1 mg alpha-acetoxytamoxifen per mg DNA. After enzymatic hydrolysis to nucleosides, the most highly modified DNA samples were analyzed by HPLC-UV, which indicated the presence of two adduct peaks in approximately a 1:4 ratio. The major adduct was isolated, rigorously characterized as (E)-alpha-(deoxyguanosin-N(2)-yl)tamoxifen, and quantified on the basis of its molar extinction coefficient. A similar reaction was conducted with [N(CD(3))(2)]-alpha-acetoxytamoxifen to prepare a deuterated adduct that could serve as an internal standard for ES-MS/MS. The limit of detection for the HPLC-ES-MS/MS method was approximately 5 adducts/10(9) nucleotides, with an intra- and interassay precision of 3% relative standard deviation. The method was validated over the range of 8-1 520,000 adducts/10(8) nucleotides using 100 microg samples of DNA modified in vitro. Analysis of liver DNA from female Sprague-Dawley rats treated by gavage with seven daily doses of 20 mg tamoxifen/kg body weight gave a value of 496 +/- 16 adducts/10(8) nucleotides for (E)-alpha-(deoxyguanosin-N(2)-yl)tamoxifen and 626 +/- 18 adducts/10(8) nucleotides for (E)-alpha-(deoxyguanosin-N(2)-yl)-N-desmethyltamoxifen. These data indicate that the HPLC-ES-MS/MS methodology has sufficient sensitivity and precision to be useful in the analysis of tamoxifen DNA adducts formed in vivo in experimental models and may be able to detect tamoxifen DNA adduct formation in human tissue samples.

  19. Physico-chemical stability of butorphanol-tramadol and butorphanol-fentanyl patient-controlled analgesia infusion solutions over 168 hours.

    PubMed

    Chen, Fuchao; Fang, Baoxia; Li, Peng; Zhu, Xuesong; Zhou, Benhong

    2014-08-01

    This study was to investigate the physical and chemical compatibility of butorphanol with tramadol or fentanyl in 0.9% sodium chloride injections for patient controlled analgesia administration. The solutions were prepared in polyvinyl chloride (PVC) infusion bags and stored without protected from light exposure at room temperature (25 degrees C) or refrigerated (4 degrees C). Over a period of 168 hours, stabilities were determined by visual inspection, pH measurement, and high-pressure liquid chromatography (HPLC) assay of drug concentrations. At both temperatures, admixtures of butorphanol-tramadol and butorphanol-fentanyl were clear in appearance, and no color change or precipitation was observed during the study period. The maximum losses obtained were lower than 5% for the three drugs after 168 hours of storage. The results indicate that, at ambient or refrigerated storage conditions, the drug mixtures of butorphanol-tramadol and butorphanol-fentanyl in 0.9% sodium chloride injections were physically and chemically stable for at least 168 hours when stored in PVC syringes.

  20. Potency and Stability of Intradermal Capsaicin: Implications for Use as a Human Model of Pain in Multicenter Clinical Trials

    PubMed Central

    Balabathula, Pavan; Bhattacharjee, Himanshu; Thoma, Laura A; Nolly, Robert J; Horton, Frank P; Stornes, Gwendolyn D; Wan, Jim Y; Brooks, Ian M; Bachmann, Gloria A; Foster, David C; Brown, Candace S

    2014-01-01

    Intradermally injected capsaicin has been used extensively both as a human pain model and to assess analgesic efficacy. Factors such as dose, formulation, route, and site are known to affect its sensitivity. We determined whether potency and stability of capsaicin solutions were further sources of variability when following strict manufacturing guidelines. Capsaicin solution (1.0 mg/mL) was prepared according to Current Good Manufacturing Practice (cGMP) guidelines and aseptically filled into sterile amber borosilicate vials and stored at 5°C, 25°C, and 30°C. All samples were analyzed at one, three, six, and twelve months. Chemical stability was determined using HPLC and physical stability was evaluated by visual inspection of color changes, clarity, particulate matter, and product/ container closure abnormalities during each sampling time. Capsaicin intradermal injection was found to be sterile and retained 95% of the initial concentration for at least one year, regardless of studied storage temperatures (P<0.0001). Visual inspection indicated no changes in color, clarity, particulate matter, and product/ container closure abnormalities in all samples. These data show that capsaicin solutions (1.0 mg/mL) maintain their potency and stability over one year when manufactured according to cGMP guidelines. These results suggest that in clinical trials manufacturing of capsaicin solutions is recommended over extemporaneous compounding. PMID:25105064

  1. Application of natural deep eutectic solvents to the extraction of anthocyanins from Catharanthus roseus with high extractability and stability replacing conventional organic solvents.

    PubMed

    Dai, Yuntao; Rozema, Evelien; Verpoorte, Robert; Choi, Young Hae

    2016-02-19

    Natural deep eutectic solvents (NADES) have attracted a great deal of attention in recent times as promising green media. They are generally composed of neutral, acidic or basic compounds that form liquids of high viscosity when mixed in certain molar ratio. Despite their potential, viscosity and acid or basic nature of some ingredients may affect the extraction capacity and stabilizing ability of the target compounds. To investigate these effects, extraction with a series of NADES was employed for the analysis of anthocyanins in flower petals of Catharanthus roseus in combination with HPLC-DAD-based metabolic profiling. Along with the extraction yields of anthocyanins their stability in NADES was also studied. Multivariate data analysis indicates that the lactic acid-glucose (LGH), and 1,2-propanediol-choline chloride (PCH) NADES present a similar extraction power for anthocyanins as conventional organic solvents. Furthermore, among the NADES employed, LGH exhibits an at least three times higher stabilizing capacity for cyanidins than acidified ethanol, which facilitates their extraction and analysis process. Comparing NADES to the conventional organic solvents, in addition to their reduced environmental impact, they proved to provide higher stability for anthocyanins, and therefore have a great potential as possible alternatives to those organic solvents in health related areas such as food, pharmaceuticals and cosmetics. Copyright © 2016 Elsevier B.V. All rights reserved.

  2. Analysis of the extracts of Isatis tinctoria by new analytical approaches of HPLC, MS and NMR.

    PubMed

    Zhou, Jue; Qu, Fan

    2011-01-01

    The methods of extraction, separation and analysis of alkaloids and indole glucosinolates (GLs) ofIsatis tinctoria were reviewed. Different analytical approaches such as High-pressure Liquid Chromatography (HPLC), Liquid Chromatography with Electrospray Ionization Mass Spectrometry (LC/ESI/MS), Electrospray Ionization Time-Of-Flight Mass Spectrometry (ESI-TOF-MS), and Nuclear Magnetic Resonance (NMR) were used to validate and identity of these constituents. These methods provide rapid separation, identification and quantitative measurements of alkaloids and GLs of Isatis tinctoria. By connection with different detectors to HPLC such as PDA, ELSD, ESI- and APCI-MS in positive and negative ion modes, complicated compounds could be detected with at least two independent detection modes. The molecular formula can be derived in a second step of ESI-TOF-MS data. But for some constituents, UV and MS cannot provide sufficient structure identification. After peak purification, NMR by semi-preparative HPLC can be used as a complementary method.

  3. PLS-LS-SVM based modeling of ATR-IR as a robust method in detection and qualification of alprazolam

    NASA Astrophysics Data System (ADS)

    Parhizkar, Elahehnaz; Ghazali, Mohammad; Ahmadi, Fatemeh; Sakhteman, Amirhossein

    2017-02-01

    According to the United States pharmacopeia (USP), Gold standard technique for Alprazolam determination in dosage forms is HPLC, an expensive and time-consuming method that is not easy to approach. In this study chemometrics assisted ATR-IR was introduced as an alternative method that produce similar results in fewer time and energy consumed manner. Fifty-eight samples containing different concentrations of commercial alprazolam were evaluated by HPLC and ATR-IR method. A preprocessing approach was applied to convert raw data obtained from ATR-IR spectra to normal matrix. Finally, a relationship between alprazolam concentrations achieved by HPLC and ATR-IR data was established using PLS-LS-SVM (partial least squares least squares support vector machines). Consequently, validity of the method was verified to yield a model with low error values (root mean square error of cross validation equal to 0.98). The model was able to predict about 99% of the samples according to R2 of prediction set. Response permutation test was also applied to affirm that the model was not assessed by chance correlations. At conclusion, ATR-IR can be a reliable method in manufacturing process in detection and qualification of alprazolam content.

  4. Determination of etoxazole residues in fruits and vegetables by SPE clean-up and HPLC-DAD.

    PubMed

    Malhat, Farag; Badawy, Hany; Barakat, Dalia; Saber, Ayman

    2013-01-01

    A method for determination of etoxazole residues in apples, strawberries and green beans was developed and validated. The analyte was extracted with acetonitrile from foodstuff and a charcoal-celite cartridge was used for clean-up of raw extracts. Reversed phase high performance liquid chromatography with photodiode array detector (HPLC-DAD) was used for the determination and quantification of etoxazole residues in the studied samples. The calibration graphs of etoxazole in a solvent or three blank matrixes were linear within the tested intervals 0.01-2 mg L(-1), with correlation coefficient of determination >0.999. The combined solid phase extraction (SPE) clean-up and the chromatographic method steps were sensitive and reliable for simultaneous determination of etoxazole residues in the studied samples. The average recoveries of etoxazole in the tested foodstuffs were between 93.4 to 102% at spiking levels of 0.01, 0.10, and 0.50 mg kg(-1), with relative standard deviations ranging from 2.8 to 4.7%, in agreement with directives for method validation in residue analyses. The limit of detection (LOD) of the HPLC-DAD system was 100 pg. The limit of quantification of the entire method was 0.01 mg kg(-1).

  5. Non-invasive measurement of thyroid hormone in feces of a diverse array of avian and mammalian species.

    PubMed

    Wasser, Samuel K; Azkarate, Jurgi Cristòbal; Booth, Rebecca K; Hayward, Lisa; Hunt, Kathleen; Ayres, Katherine; Vynne, Carly; Gobush, Kathleen; Canales-Espinosa, Domingo; Rodríguez-Luna, Ernesto

    2010-08-01

    We developed and validated a non-invasive thyroid hormone measure in feces of a diverse array of birds and mammals. An I(131) radiolabel ingestion study in domestic dogs coupled with High Pressure Liquid Chromatography (HPLC) analysis, showed that peak excretion in feces occurred at 24-48h post-ingestion, with I(131)-labelled thyroid hormone metabolites excreted primarily as triiodothyronine (T3) and relatively little thyroxine (T4), at all excretion times examined. The immunoreactive T3 profile across these same HPLC fractions closely corresponded with the I(131) radioactive profile. By contrast, the T4 immunoreactive profile was disproportionately high, suggesting that T4 excretion included a high percentage of T4 stores. We optimized and validated T3 and T4 extraction and assay methods in feces of wild northern spotted owls, African elephants, howler monkeys, caribou, moose, wolf, maned wolf, killer whales and Steller sea lions. We explained 99% of the variance in high and low T3 concentrations derived from species-specific sample pools, after controlling for species and the various extraction methods tested. Fecal T3 reflected nutritional deficits in two male and three female howler monkeys held in captivity for translocation from a highly degraded habitat. Results suggest that thyroid hormone can be accurately and reliably measured in feces, providing important indices for environmental physiology across a diverse array of birds and mammals. Copyright 2010 Elsevier Inc. All rights reserved.

  6. Metabolic fate of cardiac glycosides and flavonoids upon fermentation of aqueous sea squill (Drimia maritima L.) extracts.

    PubMed

    Knittel, Diana N; Stintzing, Florian C; Kammerer, Dietmar R

    2015-06-10

    Sea squill (Drimia maritima L.) extracts have been used for centuries for the medical treatment of heart diseases. A procedure for the preparation of Drimia extracts applied for such purposes comprising a fermentation step is described in the German Homoeopathic Pharmacopoeia (GHP). However, little is known about the secondary metabolite profile of such extracts and the fate of these components upon processing and storage. Thus, in the present study sea squill extracts were monitored during fermentation and storage by HPLC-DAD-MS(n) and GC-MS to characterise and quantitate individual cardiac glycosides and phenolic compounds. For this purpose, a previously established HPLC method for the separation and quantitation of pharmacologically relevant cardiac glycosides (bufadienolides) was validated. Within 12 months of storage, total bufadienolide contents decreased by about 50%, which was attributed to microbial and plant enzyme activities. The metabolisation and degradation rates of individual bufadienolide glycosides significantly differed, which was attributed to differing structures of the aglycones. Further degradation of bufadienolide aglycones was also observed. Besides reactions well known from human metabolism studies, dehydration of individual compounds was monitored. Quantitatively predominating flavonoids were also metabolised throughout the fermentation process. The present study provides valuable information about the profile and stability of individual cardiac glycosides and phenolic compounds in fermented Drimia extracts prepared for medical applications, and expands the knowledge of cardiac glycoside conversion upon microbial fermentation. Copyright © 2015 Elsevier B.V. All rights reserved.

  7. Coupling of on-column trypsin digestion-peptide mapping and principal component analysis for stability and biosimilarity assessment of recombinant human growth hormone.

    PubMed

    Shatat, Sara M; Eltanany, Basma M; Mohamed, Abeer A; Al-Ghobashy, Medhat A; Fathalla, Faten A; Abbas, Samah S

    2018-01-01

    Peptide mapping (PM) is a vital technique in biopharmaceutical industry. The fingerprint obtained helps to qualitatively confirm host stability as well as verify primary structure, purity and integrity of the target protein. Yet, in-solution digestion followed by tandem mass spectrometry is not suitable as a routine quality control test. It is time consuming and requires sophisticated, expensive instruments and highly skilled operators. In an attempt to enhance the fuctionality of PM and extract multi-dimentional data about various critical quality attributes and comparability of biosimilars, coupling of PM generated using immobilized trypsin followed by HPLC-UV to principal component analysis (PCA) is proposed. Recombinant human growth hormone (rhGH); was selected as a model biopharmaceutical since it is available in the market from different manufacturers and its PM is a well-established pharmacopoeial test. Samples of different rhGH biosimilars as well as degraded samples: deamidated and oxidized were subjected to trypsin digestion followed by RP-HPLC-UV analysis. PCA of the entire chromatograms of test and reference samples was then conducted. Comparison of the scores of samples and investigation of the loadings plots clearly indicated the applicability of PM-PCA for: i) identity testing, ii) biosimilarity assessment and iii) stability evaluation. Hotelling's T 2 and Q statistics were employed at 95% confidence level to measure the variation and to test the conformance of each sample to the PCA model, respectively. Coupling of PM to PCA provided a novel tool to identify peptide fragments responsible for variation between the test and reference samples as well as evaluation of the extent and relative significance of this variability. Transformation of conventional PM that is largely based on subjective visual comparison into an objective statiscally-guided analysis framework should provide a simple and economic tool to help both manufacturers and regulatory authorities in quality and biosimilarity assessment of biopharmaceuticals. Copyright © 2017 Elsevier B.V. All rights reserved.

  8. Simultaneous Quantification of Limonin, Two Indolequinazoline Alkaloids, and Four Quinolone Alkaloids in Evodia rutaecarpa (Juss.) Benth by HPLC-DAD Method.

    PubMed

    Zhang, Pei-Ting; Pan, Bi-Yan; Liao, Qiong-Feng; Yao, Mei-Cun; Xu, Xin-Jun; Wan, Jin-Zhi; Liu, Dan; Xie, Zhi-Yong

    2013-01-01

    A simple and efficient HPLC-DAD (225 nm) method was developed and validated for the simultaneous determination of limonin and six key alkaloids (evodiamine, rutaecarpine, 1-methyl-2-undecyl-4(1H)-quinolone, evocarpine, 1-methy-2-[(6Z,9Z)]-6,9-pentadecadienyl-4-(1H)-quinolone, and dihydroevocarpine) in Evodia rutaecarpa (Juss.) Benth, which has been widely used as one of the Traditional Chinese Medicines. The chromatographic separation was carried out on a Hypersil BDS C18 column, and gradient elution was employed with a mobile phase containing acetonitrile and water. Contents of the analytes in 18 batches of samples were analyzed by ultrasonic extraction with ethanol and water mixture (80 : 20, v/v) followed by HPLC analysis. Separation of the seven analytes was achieved within 60 min with good linearity (r > 0.999). The RSD of both the intraday and interday precision was below 1.85%. The accuracy at different concentrations was within the range of 97.91 to 100.49%. Hierarchical clustering analysis was performed to differentiate and classify the samples based on the contents of the seven constituents. This study indicated that the quality control of E. rutaecarpa could be simplified to the measurement of four constituents, and that limonin, 1-methyl-2-undecyl-4(1H)-quinolone, and dihydroevocarpine should also be served as the chemical markers together with evodiamine for the quality control of Evodia rutaecarpa (Juss.) Benth.

  9. Simultaneous Quantification of Limonin, Two Indolequinazoline Alkaloids, and Four Quinolone Alkaloids in Evodia rutaecarpa (Juss.) Benth by HPLC-DAD Method

    PubMed Central

    Zhang, Pei-ting; Pan, Bi-yan; Liao, Qiong-feng; Yao, Mei-cun; Xu, Xin-jun; Wan, Jin-zhi; Liu, Dan; Xie, Zhi-yong

    2013-01-01

    A simple and efficient HPLC-DAD (225 nm) method was developed and validated for the simultaneous determination of limonin and six key alkaloids (evodiamine, rutaecarpine, 1-methyl-2-undecyl-4(1H)-quinolone, evocarpine, 1-methy-2-[(6Z,9Z)]-6,9-pentadecadienyl-4-(1H)-quinolone, and dihydroevocarpine) in Evodia rutaecarpa (Juss.) Benth, which has been widely used as one of the Traditional Chinese Medicines. The chromatographic separation was carried out on a Hypersil BDS C18 column, and gradient elution was employed with a mobile phase containing acetonitrile and water. Contents of the analytes in 18 batches of samples were analyzed by ultrasonic extraction with ethanol and water mixture (80 : 20, v/v) followed by HPLC analysis. Separation of the seven analytes was achieved within 60 min with good linearity (r > 0.999). The RSD of both the intraday and interday precision was below 1.85%. The accuracy at different concentrations was within the range of 97.91 to 100.49%. Hierarchical clustering analysis was performed to differentiate and classify the samples based on the contents of the seven constituents. This study indicated that the quality control of E. rutaecarpa could be simplified to the measurement of four constituents, and that limonin, 1-methyl-2-undecyl-4(1H)-quinolone, and dihydroevocarpine should also be served as the chemical markers together with evodiamine for the quality control of Evodia rutaecarpa (Juss.) Benth. PMID:23738236

  10. Towards multimodal HPLC separations on humic acid-bonded aminopropyl silica: RPLC and HILIC behavior.

    PubMed

    Gezici, Orhan; Kara, Hüseyin

    2011-09-15

    The stationary phase characteristics of the material obtained through immobilization of humic acid (HA) to aminopropyl silica (APS) via amide-bond formation were investigated. The material was characterized in terms of elemental analysis, FTIR, thermogravimetric analyses, pH point of zero charge measurements, potentiometric titrations, and contact angle measurements. Amount of HA bonded to APS was determined from the elemental analysis results, and found as 170 mgHA/gAPS. Stability of the material was studied in aqueous media at different pH values, and amount of HA released at pH=8 did not exceed 2% of the total immobilized HA. Stationary phase characteristics of the well-characterized material were investigated in an HPLC system by using some low-molecular weight polar compounds (i.e. some nucleosides and nucleobases) as test solutes. Effect of some experimental variables such as column conditioning, composition of mobile phase, and temperature on the chromatographic behavior of the studied compounds was studied. Role of ammonium solutions at different pH values on retentive properties of the species was also studied. Retention factors (k') versus volume percentage of organic modifier exhibited a U-curve, which was evaluated as an indication for RPLC/HILIC mixed-mode behavior of the stationary phase. Orthogonality between RPLC and HILIC modes was analyzed through geometric approach, and found as 48.5%. Base-line separation for the studied groups of compounds was achieved under each studied mode, and some differentiations were observed in elution order of the compounds depending on the HPLC mode applied. Chromatograms recorded under RPLC and HILIC modes were compared with those recorded on APS under similar conditions, and thus the influence/importance of HA immobilization process was evaluated in detail. In light of the obtained results, immobilized HA is represented as a useful stationary phase for HPLC separations. Copyright © 2011 Elsevier B.V. All rights reserved.

  11. Preparation and Characterization of Rivastigmine Transdermal Patch Based on Chitosan Microparticles.

    PubMed

    Sadeghi, Mohsen; Ganji, Fariba; Taghizadeh, Seyyed Mojtaba; Daraei, Bahram

    2016-01-01

    Here we report a novel approach for preparation of a 6-day transdermal drug delivery system (TDDS) as treatment for mild to moderate Alzheimer's disease. The spray drying method was used to prepare microparticles containing the anti-Alzheimer drug, Rivastigmine, in combination with the natural polymer, chitosan, for transdermal drug delivery applications. The content of the drug was determined by High Performance Liquid Chromatography (HPLC) method which was validated as per FDA guidelines. The morphology and size range of the microparticles were determined; and the effect of drug concentration in the solution injected into the spray dryer on the particles characterizations was studied. The stability of Rivastigmine at high temperature was confirmed using FTIR analysis as well as a validate HPLC assay. The obtained results show that the drug was stable at high temperatures with 7 to 42% loading in the microparticles, and the higher drug concentrations of the solution injected into the spray dryer resulted in increase of the drug loading, surface drug and microparticles distortion. The TDDS containing the microparticles was also prepared with microparticle to dry adhesive ratios of 5, 10 and 15% using acrylic adhesive. Based on adhesion properties of the patches, gained from the probe tack and the peel adhesion 180° tests, and the 15% patch by having more drug content per unit area of the patch, and still having similar adhesion properties was compared to the microparticles-free patch of 5.1% Rivastigmine salt (equivalent to the drug content of the 15% patch) from the permeation point of view by using Franz cell diffusion over 6 days. The drug permeation rate from the microparticle-free patch was slower than the 15% microparticles patch, which is the result of crystallization of Rivastigmine salt in the acrylic adhesive. The 6-day-prepared TDDS can be considered as an alternative for one-week application of 6 Exelon patches.

  12. A newly validated high-performance liquid chromatography method with diode array ultraviolet detection for analysis of the antimalarial drug primaquine in the blood plasma.

    PubMed

    Carmo, Ana Paula Barbosa do; Borborema, Manoella; Ribeiro, Stephan; De-Oliveira, Ana Cecilia Xavier; Paumgartten, Francisco Jose Roma; Moreira, Davyson de Lima

    2017-01-01

    Primaquine (PQ) diphosphate is an 8-aminoquinoline antimalarial drug with unique therapeutic properties. It is the only drug that prevents relapses of Plasmodium vivax or Plasmodium ovale infections. In this study, a fast, sensitive, cost-effective, and robust method for the extraction and high-performance liquid chromatography with diode array ultraviolet detection (HPLC-DAD-UV ) analysis of PQ in the blood plasma was developed and validated. After plasma protein precipitation, PQ was obtained by liquid-liquid extraction and analyzed by HPLC-DAD-UV with a modified-silica cyanopropyl column (250mm × 4.6mm i.d. × 5μm) as the stationary phase and a mixture of acetonitrile and 10mM ammonium acetate buffer (pH = 3.80) (45:55) as the mobile phase. The flow rate was 1.0mL·min-1, the oven temperature was 50OC, and absorbance was measured at 264nm. The method was validated for linearity, intra-day and inter-day precision, accuracy, recovery, and robustness. The detection (LOD) and quantification (LOQ) limits were 1.0 and 3.5ng·mL-1, respectively. The method was used to analyze the plasma of female DBA-2 mice treated with 20mg.kg-1 (oral) PQ diphosphate. By combining a simple, low-cost extraction procedure with a sensitive, precise, accurate, and robust method, it was possible to analyze PQ in small volumes of plasma. The new method presents lower LOD and LOQ limits and requires a shorter analysis time and smaller plasma volumes than those of previously reported HPLC methods with DAD-UV detection. The new validated method is suitable for kinetic studies of PQ in small rodents, including mouse models for the study of malaria.

  13. Phenolic compounds participating in mulberry juice sediment formation during storage.

    PubMed

    Zou, Bo; Xu, Yu-Juan; Wu, Ji-Jun; Yu, Yuan-Shan; Xiao, Geng-Sheng

    The stability of clarified juice is of great importance in the beverage industry and to consumers. Phenolic compounds are considered to be one of the main factors responsible for sediment formation. The aim of this study is to investigate the changes in the phenolic content in clarified mulberry juice during storage. Hence, separation, identification, quantification, and analysis of the changes in the contents of phenolic compounds, both free and bound forms, in the supernatant and sediments of mulberry juice, were carried out using high performance liquid chromatographic system, equipped with a photo-diode array detector (HPLC-PDA) and HPLC coupled with quadrupole-time of flight mass spectrometric (HPLC-QTOF-MS/MS) techniques. There was an increase in the amount of sediment formed over the period of study. Total phenolic content of supernatant, as well as free phenolic content in the extracts of the precipitate decreased, whereas the bound phenolic content in the sediment increased. Quantitative estimation of individual phenolic compounds indicated high degradation of free anthocyanins in the supernatant and sediment from 938.60 to 2.30 mg/L and 235.60 to 1.74 mg/g, respectively. A decrease in flavonoids in the supernatant was also observed, whereas the contents of bound forms of gallic acid, protocatechuic acid, caffeic acid, and rutin in the sediment increased. Anthocyanins were the most abundant form of phenolics in the sediment, and accounted for 67.2% of total phenolics after 8 weeks of storage. These results revealed that phenolic compounds, particularly anthocyanins, were involved in the formation of sediments in mulberry juice during storage.

  14. HPLC Plasma Assay of a Novel Anti-MRSA Compound, Kaempferol-3-O-Alpha-L-(2",3"-di-p-coumaroyl)rhamnoside, from Sycamore Leaves.

    PubMed

    Zhang, Yiguan; Valeriote, Frederick; Swartz, Kenneth; Chen, Ben; Hamann, Mark T; Rodenburg, Douglas L; McChesney, James D; Shaw, Jiajiu

    2015-08-01

    Methicillin-resistant Staphylococcus aureus (MRSA) is a serious pathogen that is resistant to current antibiotic therapy. Thus, there is an urgent need for novel antimicrobial agents that can effectively combat these new strains of drug-resistant "superbugs". Recently, fractionation of an extract from Platanus occidentalis (American sycamore) leaves produced an active kaempferol molecule, 3-O-alpha-L-(2",3"-di-p-coumaroyl)rhamnoside (KCR), in four isomeric forms; all four isomers exhibit potent anti-MRSA activity. In order to further the preclinical development of KCR as a new antibiotic class, we developed and validated a simple analytical method for assaying KCR plasma concentration. Because KCR will be developed as a new drug, although comprising four stereoisomers, the analytical method was devised to assay the total amount of all four isomers. In the present work, both a plasma processing procedure and an HPLC method have been developed and validated. Mouse plasma containing KCR was first treated with ethanol and then centrifuged. The supernatant was dried, suspended in ethanol, centrifuged, and the supernatant was injected into an HPLC system comprising a Waters C18, a mobile phase composing methanol, acetonitrile, and trifluoroacetic acid and monitored at 313 nm. The method was validated by parameters including a good linear correlation, a limit of quantification of 0.27 microg/mL, and high accuracy. In summary, this method allows a rapid analysis of KCR in the plasma samples for pharmacokinetics studies.

  15. HPLC Plasma Assay of a Novel Anti-MRSA Compound, Kaempferol-3-O-Alpha-L-(2",3"-di-p-coumaroyl)rhamnoside, from Sycamore Leaves

    PubMed Central

    Zhang, Yiguan; Valeriote, Frederick; Swartz, Kenneth; Chen, Ben; Hamann, Mark T.; Rodenburg, Douglas L.; McChesney, James D.

    2016-01-01

    Methicillin-resistant Staphylococcus aureus (MRSA) is a serious pathogen that is resistant to current antibiotic therapy. Thus, there is an urgent need for novel antimicrobial agents that can effectively combat these new strains of drug-resistant “superbugs”. Recently, fractionation of an extract from Platanus occidentalis (American sycamore) leaves produced an active kaempferol molecule, 3-O-alpha-L-(2",3"-di-p-coumaroyl)rhamnoside (KCR), in four isomeric forms; all four isomers exhibit potent anti-MRSA activity. In order to further the preclinical development of KCR as a new antibiotic class, we developed and validated a simple analytical method for assaying KCR plasma concentration. Because KCR will be developed as a new drug, although comprising four stereoisomers, the analytical method was devised to assay the total amount of all four isomers. In the present work, both a plasma processing procedure and an HPLC method have been developed and validated. Mouse plasma containing KCR was first treated with ethanol and then centrifuged. The supernatant was dried, suspended in ethanol, centrifuged, and the supernatant was injected into an HPLC system comprising a Waters C18, a mobile phase composing methanol, acetonitrile, and trifluoroacetic acid and monitored at 313 nm. The method was validated by parameters including a good linear correlation, a limit of quantification of 0.27 µg/mL, and high accuracy. In summary, this method allows a rapid analysis of KCR in the plasma samples for pharmacokinetics studies. PMID:26434123

  16. Quality, immunogenicity and stability of meningococcal serogroup ACWY-CRM197, DT and TT glycoconjugate vaccines.

    PubMed

    Beresford, Nicola J; Martino, Angela; Feavers, Ian M; Corbel, Michael J; Bai, Xilian; Borrow, Ray; Bolgiano, Barbara

    2017-06-16

    A physicochemical and immunological study of the stability of three different meningococcal (Men) ACWY conjugate vaccines was performed to evaluate any patterns of serogroup oligo- or polysaccharide-specific or carrier protein-specific stability that would affect immunogenicity. Critical quality and stability-indicating characteristics were measured, with the study supporting the suitability of both HPLC-SEC and HPAEC-PAD methods to detect changes following inappropriate vaccine storage. All three final products, ACWY-CRM 197 , -DT and -TT conjugate vaccines had expected quality indicator values and similar immunogenicity in a mouse model (anti-PS IgG and rSBA) when stored at +2-8°C. When stored at ≥+37°C, all conjugated carrier proteins and serogroup saccharides were affected. Direct correlations were observed between the depolymerization of the MenA saccharide as evidenced by a size-reduction in the MenA conjugates (CRM 197 , DT and TT) and their immunogenicity. MenA was the most labile serogroup, followed by MenC; then MenW and Y, which were similar. At high temperatures, the conjugated carrier proteins were prone to unfolding and/or aggregation. The anti-MenC IgG responses of the multivalent conjugate vaccines in mice were equivalent to those observed in monovalent MenC conjugate vaccines, and were independent of the carrier protein. For any newly developing MenACWY saccharide-protein conjugate vaccines, a key recommendation would be to consider the lyophilization of final product to prevent deleterious degradation that would affect immunogenicity. Crown Copyright © 2017. Published by Elsevier Ltd. All rights reserved.

  17. Ultra-performance liquid chromatography/tandem mass spectrometric quantification of structurally diverse drug mixtures using an ESI-APCI multimode ionization source.

    PubMed

    Yu, Kate; Di, Li; Kerns, Edward; Li, Susan Q; Alden, Peter; Plumb, Robert S

    2007-01-01

    We report in this paper an ultra-performance liquid chromatography/tandem mass spectrometric (UPLC(R)/MS/MS) method utilizing an ESI-APCI multimode ionization source to quantify structurally diverse analytes. Eight commercial drugs were used as test compounds. Each LC injection was completed in 1 min using a UPLC system coupled with MS/MS multiple reaction monitoring (MRM) detection. Results from three separate sets of experiments are reported. In the first set of experiments, the eight test compounds were analyzed as a single mixture. The mass spectrometer was switching rapidly among four ionization modes (ESI+, ESI-, APCI-, and APCI+) during an LC run. Approximately 8-10 data points were collected across each LC peak. This was insufficient for a quantitative analysis. In the second set of experiments, four compounds were analyzed as a single mixture. The mass spectrometer was switching rapidly among four ionization modes during an LC run. Approximately 15 data points were obtained for each LC peak. Quantification results were obtained with a limit of detection (LOD) as low as 0.01 ng/mL. For the third set of experiments, the eight test compounds were analyzed as a batch. During each LC injection, a single compound was analyzed. The mass spectrometer was detecting at a particular ionization mode during each LC injection. More than 20 data points were obtained for each LC peak. Quantification results were also obtained. This single-compound analytical method was applied to a microsomal stability test. Compared with a typical HPLC method currently used for the microsomal stability test, the injection-to-injection cycle time was reduced to 1.5 min (UPLC method) from 3.5 min (HPLC method). The microsome stability results were comparable with those obtained by traditional HPLC/MS/MS.

  18. Stability and compatibility of anakinra with ceftriaxone sodium injection in 0.9% sodium chloride or 5% dextrose injection.

    PubMed

    Nahata, M C; Morosco, R S; Sabados, B K; Weber, T R

    1997-06-01

    The stability and compatibility of anakinra (recombinant human interleukin-1 receptor antagonist) with ceftriaxone sodium in 0.9% sodium chloride or 5% dextrose injection was determined during a 4-h period at ambient room temperature and light. Anakinra was diluted in 0.9% sodium chloride or 5% dextrose to the concentrations of 4 and 36 mg/ml. Anakinra, at each concentration was mixed with ceftriaxone sodium (20 mg/ml) in a 50:50 proportion and stored in plastic culture vials with polypropylene caps. The samples were collected at 0, 2 and 4 h after mixing. Anakinra and ceftriaxone concentrations were measured using stability-indicating HPLC methods. In 0.9% sodium chloride injection, the mean concentrations of anakinra and ceftriaxone exceeded 98% of initial concentrations at the end of the study period. In 5% dextrose, however, anakinra concentrations were below 90% of the expected initial concentration at the time of first analysis (within 0.5 h). Thus, anakinra appears to be stable and compatible with ceftriaxone sodium when diluted in 0.9% sodium chloride injection, but not in 5% dextrose injection over 4 h at ambient room temperature and light.

  19. Characterisation and stability of anthocyanins in purple-fleshed sweet potato P40.

    PubMed

    Xu, Jianteng; Su, Xiaoyu; Lim, Soyoung; Griffin, Jason; Carey, Edward; Katz, Benjamin; Tomich, John; Smith, J Scott; Wang, Weiqun

    2015-11-01

    Purple-fleshed sweet potato P40 has been shown to prevent colorectal cancer in a murine model. This study is to identify anthocyanins by using HPLC/MS-MS and assess the stability during various cooking conditions. P40 possesses a high content of anthocyanins up to 14 mg/g dry matter. Total 12 acylated anthocyanins are identified. Top three anthocyanins, e.g., cyanidin 3-caffeoyl-p-hydroxybenzoyl sophoroside-5-glucoside, peonidin 3-caffeoyl sophoroside-5-glucoside, and cyanidin 3-(6"-caffeoyl-6"-feruloylsophoroside)-5-glucoside, account for half of the anthocyanin contents. Over 80% of anthocyanins measured by acid hydrolysis were cyanidin derivatives, indicating P40 is unique when compared with other purple-fleshed sweet potatoes that usually contain more peonidin than cyanidin. Steaming, pressure cooking, microwaving, and frying but not baking significantly reduced 8-16% of total anthocyanin contents. Mono-acylated anthocyanins showed a higher resistance against heat than di- and non-acylated. Among of which, cyanidin 3-p-hydroxybenzoylsophoroside-5-glucoside exhibited the best thermal stability. The stable acylated and cyanidin-predominated anthocyanins in P40 may provide extra benefits for cancer prevention. Copyright © 2014 Elsevier Ltd. All rights reserved.

  20. Development and validation of a specific and sensitive HPLC-ESI-MS method for quantification of lysophosphatidylinositols and evaluation of their levels in mice tissues.

    PubMed

    Masquelier, Julien; Muccioli, Giulio G

    2016-07-15

    Increasing evidence suggests that lysophosphatidylinositols (LPIs), a subspecies of lysophospholipids, are important endogenous mediators. Although LPIs long remained among the less studied lysophospholipids, the identification of GPR55 as their molecular target sparked a renewed interest in the study of these bioactive lipids. Furthermore, increasing evidence points towards a role for LPIs in cancer development. However, a better understanding of the role and functions of LPIs in physiology and disease requires methods that allow for the quantification of LPI levels in cells and tissues. Because dedicated efficient methods for quantifying LPIs were missing, we decided to develop and validate an HPLC-ESI-MS method for the quantification of LPI species from tissues. LPIs are extracted from tissues by liquid/liquid extraction, pre-purified by solid-phase extraction, and finally analyzed by HPLC-ESI-MS. We determined the method's specificity and selectivity, we established calibration curves, determined the carry over (< 2%), LOD and LLOQ (between 0.116-7.82 and 4.62-92.5pmol on column, respectively), linearity (0.988 80%), intermediate precision (CV<20%) as well as the recovery from tissues. We then applied the method to determine the relative abundance of the LPI species in 15 different mouse tissues. Finally, we quantified the absolute LPI levels in six different mouse tissues. We found that while 18:0 LPI represents more than 60% of all the LPI species in the periphery (e.g. liver, gastrointestinal tract, lungs, spleen) it is much less abundant in the central nervous system where the levels of 20:4 LPI are significantly higher. Thus this validated HPLC-ESI-MS method for quantifying LPIs represents a powerful tool that will facilitate the comprehension of the pathophysiological roles of LPIs. Copyright © 2016 Elsevier B.V. All rights reserved.

  1. Simultaneous detection and quantification of parecoxib and valdecoxib in canine plasma by HPLC with spectrofluorimetric detection: development and validation of a new methodology.

    PubMed

    Saccomanni, G; Giorgi, M; Del Carlo, S; Manera, C; Saba, A; Macchia, M

    2011-09-01

    Parecoxib is the injectable prodrug of valdecoxib, a cicloxygenase-2 selective drug, currently used in human medicine. Recent studies have suggested both its excellent clinical effectiveness and wide safety profile. The aim of the present study was to develop and validate a new high-performance liquid chromatography (HPLC) with spectrofluorimetric detection method to quantify parecoxib and valdecoxib in canine plasma. Several parameters both in the extraction and the detection method were evaluated. The applicability of the method was determined by administering parecoxib to one dog: the protocol provided the expected pharmacokinetic results. The final mobile phase was acetonitrile: AcONH(4) (10 mM; pH 5.0) 55:45, v/v, with a flow rate of 0.4 mL min(-1), and excitation and emission wavelengths of 265 and 375 nm, respectively. The analytical column was a reverse-phase C18 ODS2 3-μm particle size. Protein precipitation in acidic medium followed by two successive liquid-liquid steps was carried out. The best extraction solvent was cyclohexane:Et(2)O (3:2, v/v) that gave recoveries ranging from 81.1% to 89.1% and from 94.8% to 103.6% for parecoxib and valdecoxib, respectively. The limits of quantification were 25 and 10 ng mL(-1) for parecoxib and valdecoxib, respectively. The chromatographic runs were specific with no interfering peaks at the retention times of the analytes, as confirmed by HPLC-mass spectrometry experiments. The other validation parameters were in agreement with the European Medicines Evaluation Agency and International Conference on Harmonisation guidelines. In conclusion, this method (extraction, separation and applied techniques) is simple and effective. This is the first time that use of a HPLC with spectrofluorimetric detection technique to simultaneously detect parecoxib and valdecoxib in plasma has been reported. This technique may have applications for pharmacokinetic studies.

  2. Comparative HPLC/ESI-MS and HPLC/DAD study of different populations of cultivated, wild and commercial Gentiana lutea L.

    PubMed

    Mustafa, Ahmed M; Caprioli, Giovanni; Ricciutelli, Massimo; Maggi, Filippo; Marín, Rosa; Vittori, Sauro; Sagratini, Gianni

    2015-05-01

    The root of Gentiana lutea L., famous for its bitter properties, is often used in alcoholic bitter beverages, food products and traditional medicine to stimulate the appetite and improve digestion. This study presents a new, fast, and accurate HPLC method using HPLC/ESI-MS and HPLC/DAD for simultaneous analysis of iridoids (loganic acid), secoiridoids (gentiopicroside, sweroside, swertiamarin, amarogentin) and xanthones (isogentisin) in different populations of G.lutea L., cultivated in the Monti Sibillini National Park, obtained wild there, or purchased commercially. Comparison of HPLC/ESI-MS and HPLC/DAD indicated that HPLC/ESI-MS is more sensitive, reliable and selective. Analysis of twenty samples showed that gentiopicroside is the most dominant compound (1.85-3.97%), followed by loganic acid (0.11-1.30%), isogentisin (0.03-0.48%), sweroside (0.05-0.35%), swertiamarin (0.08-0.30%), and amarogentin (0.01-0.07%). The results confirmed the high quality of the G.lutea cultivated in the Monti Sibillini National Park. Copyright © 2014 Elsevier Ltd. All rights reserved.

  3. Examination of the Psychometric Properties of the Adult Manifest Anxiety Scale-Elderly Version Scores

    ERIC Educational Resources Information Center

    Lowe, Patricia A.; Reynolds, Cecil R.

    2006-01-01

    The psychometric properties of the Adult Manifest Anxiety Scale-Elderly Version (AMAS-E) scores were evaluated in two studies. In Study 1, the temporal stability and construct validity of the AMAS-E test scores were examined in a group of 226 older adults, aged 60 years and older. Results indicated adequate to excellent temporal stability (2-week…

  4. EO-1 Hyperion reflectance time series at calibration and validation sites: stability and sensitivity to seasonal dynamics

    Treesearch

    Petya K. Entcheva Campbell; Elizabeth M. Middleton; Kurt J. Thome; Raymond F. Kokaly; Karl Fred Huemmrich; David Lagomasino; Kimberly A. Novick; Nathaniel A. Brunsell

    2013-01-01

    This study evaluated Earth Observing 1 (EO-1) Hyperion reflectance time series at established calibration sites to assess the instrument stability and suitability for monitoring vegetation functional parameters. Our analysis using three pseudo-invariant calibration sites in North America indicated that the reflectance time series are devoid of apparent spectral trends...

  5. Qualitative and quantitative analysis of the diuretic component ergone in Polyporus umbellatus by HPLC with fluorescence detection and HPLC-APCI-MS/MS.

    PubMed

    Zhao, Ying-Yong; Zhao, Ye; Zhang, Yong-Min; Lin, Rui-Chao; Sun, Wen-Ji

    2009-06-01

    Polyporus umbellatus is a widely used anti-aldosteronic diuretic in Traditional Chinese medicine (TCM). A new, sensitive and selective high-performance liquid chromatography-fluorescence detector (HPLC-FLD) and high-performance liquid chromatography-atmospheric pressure chemical ionization-mass spectrometry (HPLC-APCI-MS/MS) method for quantitative and qualitative determination of ergosta-4,6,8(14),22-tetraen-3-one(ergone), which is the main diuretic component, was provided for quality control of P. umbellatus crude drug. The ergone in the ethanolic extract of P. umbellatus was unambiguously characterized by HPLC-APCI, and further confirmed by comparing with a standard compound. The trace ergone was detected by the sensitive and selective HPLC-FLD. Linearity (r2 > 0.9998) and recoveries of low, medium and high concentration (100.5%, 100.2% and 100.4%) were consistent with the experimental criteria. The limit of detection (LOD) of ergone was around 0.2 microg/mL. Our results indicated that the content of ergone in P. umbellatus varied significantly from habitat to habitat with contents ranging from 2.13 +/- 0.02 to 59.17 +/- 0.05 microg/g. Comparison among HPLC-FLD and HPLC-UV or HPLC-APCI-MS/MS demonstrated that the HPLC-FLD and HPLC-APCI-MS/MS methods gave similar quantitative results for the selected herb samples, the HPLC-UV methods gave lower quantitative results than HPLC-FLD and HPLC-APCI-MS/MS methods. The established new HPLC-FLD method has the advantages of being rapid, simple, selective and sensitive, and could be used for the routine analysis of P. umbellatus crude drug.

  6. Single Lab Validation of a LC/UV/FLD/MS Method for Simultaneous Determination of Water-soluble Vitamins in Multi-Vitamin Dietary Supplements

    USDA-ARS?s Scientific Manuscript database

    The purpose of this study was to develop a Single-Lab Validated Method using high-performance liquid chromatography (HPLC) with different detectors (diode array detector - DAD, fluorescence detector - FLD, and mass spectrometer - MS) for determination of seven B-complex vitamins (B1 - thiamin, B2 – ...

  7. Microencapsulation of Flavors in Carnauba Wax

    PubMed Central

    Milanovic, Jelena; Manojlovic, Verica; Levic, Steva; Rajic, Nevenka; Nedovic, Viktor; Bugarski, Branko

    2010-01-01

    The subject of this study is the development of flavor wax formulations aimed for food and feed products. The melt dispersion technique was applied for the encapsulation of ethyl vanillin in wax microcapsules. The surface morphology of microparticles was investigated using scanning electron microscope (SEM), while the loading content was determined by HPLC measurements. This study shows that the decomposition process under heating proceeds in several steps: vanilla evaporation occurs at around 200 °C, while matrix degradation starts at 250 °C and progresses with maxima at around 360, 440 and 520 °C. The results indicate that carnauba wax is an attractive material for use as a matrix for encapsulation of flavours in order to improve their functionality and stability in products. PMID:22315575

  8. Microencapsulation of flavors in carnauba wax.

    PubMed

    Milanovic, Jelena; Manojlovic, Verica; Levic, Steva; Rajic, Nevenka; Nedovic, Viktor; Bugarski, Branko

    2010-01-01

    The subject of this study is the development of flavor wax formulations aimed for food and feed products. The melt dispersion technique was applied for the encapsulation of ethyl vanillin in wax microcapsules. The surface morphology of microparticles was investigated using scanning electron microscope (SEM), while the loading content was determined by HPLC measurements. This study shows that the decomposition process under heating proceeds in several steps: vanilla evaporation occurs at around 200 °C, while matrix degradation starts at 250 °C and progresses with maxima at around 360, 440 and 520 °C. The results indicate that carnauba wax is an attractive material for use as a matrix for encapsulation of flavours in order to improve their functionality and stability in products.

  9. Formulation, stability testing, and analytical characterization of melatonin-based preparation for clinical trial.

    PubMed

    Filali, Samira; Bergamelli, Charlotte; Lamine Tall, Mamadou; Salmon, Damien; Laleye, Diane; Dhelens, Carole; Diouf, Elhadji; Pivot, Christine; Pirot, Fabrice

    2017-08-01

    A new institutional clinical trial assessed the improvement of sleep disorders in 40 children with autism treated by immediate-release melatonin formulation in different regimens (0.5 mg, 2 mg, and 6 mg daily) for one month. The objectives of present study were to (i) prepare low-dose melatonin hard capsules for pediatric use controlled by two complementary methods and (ii) carry out a stability study in order to determine a use-by-date. Validation of preparation process was claimed as ascertained by mass uniformity of hard capsules. Multicomponent analysis by attenuated total reflectance Fourier transformed infrared (ATR-FTIR) of melatonin/microcrystalline cellulose mixture allowed to identify and quantify relative content of active pharmaceutical ingredients and excipients. Absolute melatonin content analysis by high performance liquid chromatography in 0.5 mg and 6 mg melatonin capsules was 93.6%±4.1% and 98.7%±6.9% of theoretical value, respectively. Forced degradation study showed a good separation of melatonin and its degradation products. The capability of the method was 15, confirming a risk of false negative <0.01%. Stability test and dissolution test were compliant over 18 months of storage with European Pharmacopoeia. Preparation of melatonin hard capsules was completed manually and melatonin in hard capsules was stable for 18 months, in spite of low doses of active ingredient. ATR-FTIR offers a real alternative to HPLC for quality control of high-dose melatonin hard capsules before the release of clinical batches.

  10. Determination of arsenic species in fish, crustacean and sediment samples from Thailand using high performance liquid chromatography (HPLC) coupled with inductively coupled plasma mass spectrometry (ICP-MS).

    PubMed

    Rattanachongkiat, S; Millward, G E; Foulkes, M E

    2004-04-01

    Suitable techniques have been developed for the extraction of arsenic species in a variety of biological and environmental samples from the Pak Pa-Nang Estuary and catchment, located in Southern Thailand, and for their determination using HPLC directly coupled with ICP-MS. The estuary catchment comprises a tin mining area and inhabitants of the region can suffer from various stages of arsenic poisoning. The important arsenic species, AsB, DMA, MMA, and inorganic arsenic (As III and V) have been determined in fish and crustacean samples to provide toxicological information on those fauna which contribute to the local diet. A Hamilton PRP-X100 anion-exchange HPLC system employing a step elution has been used successfully to achieve separation of the arsenic species. A nitric acid microwave digestion procedure, followed by carrier gas nitrogen addition- (N2)-ICP-MS analysis was used to measure total arsenic in sample digests and extracts. The arsenic speciation of the biological samples was preserved using a Trypsin enzymatic extraction procedure. Extraction efficiencies were high, with values of 82-102%(As) for fish and crustacean samples. Validation for these procedures was carried out using certified reference materials. Fish and crustacean samples from the Pak Pa-Nang Estuary showed a range for total arsenic concentration, up to 17 microg g(-1) dry mass. The major species of arsenic in all fauna samples taken was AsB, together with smaller quantities of DMA and, more importantly, inorganic As. For sediment samples, arsenic species were determined following phosphoric acid (1 M H3PO4) extraction in an open focused microwave system. A phosphate-based eluant, pH 6-7.5, with anion exchange HPLC coupled with ICP-MS was used for separation and detection of AsIII, AsV, MMA and DMA. The optimum conditions, identified using an estuarine sediment reference material (LGC), were achieved using 45 W power and a 20 minute heating period for extraction of 0.5 g sediment. The stability and recovery of arsenic species under the extraction conditions were also determined by a spiking procedure which included the estuarine sediment reference material. The results show good stability for all species after extraction with a variability of less than 10%. Total concentrations of arsenic in the sediments from the Pak Pa-Nang river catchment and the estuary covered the ranges 7-269 microg g(-1)and 4-20 [micro sign]g g(-1)(dry weight), respectively. AsV was the major species found in all the sediment samples with smaller quantities of AsIII. The presence of the more toxic inorganic forms of arsenic in both sediments and biota samples has implications for human health, particularly as they are readily 'available'.

  11. Development of a simple analytical methodology for determination of glucosamine release from modified release matrix tablets.

    PubMed

    Wu, Yunqi; Hussain, Munir; Fassihi, Reza

    2005-06-15

    A simple spectrophotometric method for determination of glucosamine release from sustained release (SR) hydrophilic matrix tablet based on reaction with ninhydrin is developed, optimized and validated. The purple color (Ruhemann purple) resulted from the reaction was stabilized and measured at 570 nm. The method optimization was essential as many procedural parameters influenced the accuracy of determination including the ninhydrin concentration, reaction time, pH, reaction temperature, purple color stability period, and glucosamine/ninhydrin ratio. Glucosamine tablets (600 mg) with different hydrophilic polymers were formulated and manufactured on a rotary press. Dissolution studies were conducted (USP 26) using deionized water at 37+/-0.2 degrees C with paddle rotation of 50 rpm, and samples were removed manually at appropriate time intervals. Under given optimized reaction conditions that appeared to be critical, glucosamine was quantitatively analyzed and the calibration curve in the range of 0.202-2.020 mg (r=0.9999) was constructed. The recovery rate of the developed method was 97.8-101.7% (n=6). Reproducible dissolution profiles were achieved from the dissolution studies performed on different glucosamine tablets. The developed method is easy to use, accurate and highly cost-effective for routine studies relative to HPLC and other techniques.

  12. Estimation of simvastatin and cetirizine by RP-LC method: Application to freeze and thaw (FT) stability studies.

    PubMed

    Naveed, Safila; Usmanghani, Khan; Sana, Aisha; Ali, Huma; Zafar, Farya; Qamar, Fatima; Sarwer, Ghulam; Abbas, Sarah; Alam, M Tanweer; Shinwari, Muhammad Ibrar

    2018-01-01

    Sensitive, simple, reliable and rapid HPLC technique for the estimation of simvastatin (SMV) and cetirizine has been designed in this study. The chromatographic conditions were set using Shimadzu LC-10 AT VP pump, with UV detector (SPD-10 AV-VP). System integration was performed with CBM-102 (Bus Module). Partitioning of components was attained with pre-packed C-18 column of Purospher Star (5 μm, 250 x 4.6 mm) at ambient conditions. Injected volume of sample was 10 μl. Mobile phase was composed of 50:50 v/v ratio of Acetonitrile/water (pH 3.0 adjusted with ortho-phosphoric acid) having 2 ml/minutes rate of flow. Compounds were detected in UV region at 225 nm. Percent Recovery of simvastatin was observed in the range of 98-102%. All results were found in accept table range of specification. The projected method is consistent, specific, precise, and rapid, that can be employed to quantitate the SMV along with cetirizine HCl. It was estimated by 3 successive cycles of freeze and thaw stability. Results of FT samples were found within accept table limits the method was developed and validated in raw materials, bulk formulations and final drug products.

  13. AN HPLC METHOD WITH UV DETECTION, PH CONTROL, AND REDUCTIVE ASCORBIC ACID FOR CYANURIC ACID ANALYSIS IN WATER

    EPA Science Inventory

    Every year over 250 million pounds of cyanuric acid (CA) and chloroisocyanurates are produced industrially. These compounds are standard ingredients in formulations for household bleaches, industrial cleansers, dishwasher compounds, general sanitizers, and chlorine stabilizers. ...

  14. The effect of packaging materials on the stability of sunscreen emulsions.

    PubMed

    Santoro, Maria Inês R M; Da Costa E Oliveira, Daniella Almança Gonçalves; Kedor-Hackmann, Erika R M; Singh, Anil K

    2005-06-13

    The purpose of this research was to study the stability of a emulsion containing UVA, UVB and infrared sunscreens after storage in different types of packaging materials (glass and plastic flasks; plastic and metallic tubes). The samples, emulsions containing benzophenone-3 (B-3), octyl methoxycinnamate (OM) and Phycocorail, were stored at 10, 25, 35 and 45 degrees C and representative samples were analyzed after 2, 7, 30, 60 and 90 days period. The stability studies were conducted by analyzing samples at pre-determined intervals by high performance liquid chromatography (HPLC) along with periodic rheological measurements.

  15. Routine low-level monitoring of polar pesticides and pesticide degradates by HPLC/ESI-MS: Evaluating long-term performance

    USGS Publications Warehouse

    Furlong, E.T.; Martin, Jeffrey D.; Werner, S.L.; Gates, Paul M.

    2002-01-01

    The sensitivity and selective determination of polar pesticides were analyzed using high-performance liquid chromatography/electrospray ionization-mass spectrometry (HPLC/ESI-MS). The effects of multiple operators and instruments on method performance were evaluated using 440 pairs of fortified reagent-water and blank reagent-water samples. The influence of varying environmental matrices on recovery and precision were also analyzed using 200 fortified ambient water samples and duplicate ambient water samples. The results show that compound stability in filtered water was matrix-, chemical class- and compound-dependent which ranged from 1 day to 2 weeks.

  16. Simultaneous determination of aliskiren and hydrochlorothiazide from their pharmaceutical preparations using a validated stability-indicating MEKC method.

    PubMed

    Sangoi, Maximiliano S; Wrasse-Sangoi, Micheli; Oliveira, Paulo R; Rolim, Clarice M B; Steppe, Martin

    2011-08-01

    A stability-indicating MEKC method was developed and validated for the simultaneous determination of aliskiren (ALI) and hydrochlorothiazide (HCTZ) in pharmaceutical formulations using ranitidine as an internal standard (IS). Optimal conditions for the separation of ALI, HCTZ and its major impurity chlorothiazide (CTZ), IS and degradation products were investigated. The method employed 47 mM Tris buffer and 47 mM anionic detergent SDS solution at pH 10.2 as the background electrolyte. MEKC method was performed on a fused-silica capillary (40 cm) at 28°C. Applied voltage was 26 kV (positive polarity) and photodiode array (PDA) detector was set at 217 nm. The method was validated in accordance with the ICH requirements. The method was linear over the concentration range of 5-100 and 60-1200 μg/mL for HCTZ and ALI, respectively (r(2) >0.9997). The stability-indicating capability of the method was established by enforced degradation studies combined with peak purity assessment using the PDA detection. Precision and accuracy evaluated by RSD were lower than 2%. The method proved to be robust by a fractional factorial design evaluation. The proposed MEKC method was successfully applied for the quantitative analysis of ALI and HCTZ both individually and in a combined dosage tablet formulation to support the quality control. Copyright © 2011 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  17. A Validated Stability-Indicating RP-UPLC Method for Simultaneous Determination of Desloratadine and Sodium Benzoate in Oral Liquid Pharmaceutical Formulations.

    PubMed

    Kumar, Navneet; Sangeetha, Dhanaraj; Reddy, Pingili Sunil; Prakash, Lakkireddy

    2012-01-01

    A novel, sensitive and selective stability-indicating gradient reverse phase ultra performance liquid chromatographic method was developed and validated for the quantitative determination of desloratadine and sodium benzoate in pharmaceutical oral liquid formulation. The chromatographic separation was achieved on Acquity BEH C8 (100 mm × 2.1 mm) 1.7 μm column by using mobile phase containing a gradient mixture of solvent A (0.05 M KH(2)PO(4) and 0.07 M triethylamine, pH 3.0) and B (50:25:25 v/v/v mixture of acetonitrile, methanol and water) at flow rate of 0.4 mL/min. Column temperature was maintained at 40°C and detection was carried out at a wavelength of 272 nm. The described method shows excellent linearity over a range of 0.254 μg/mL to 76.194 μg/mL for desloratadine and 1.006 μg/mL to 301.67 μg/mL for sodium benzoate. The correlation coefficient for desloratadine and sodium benzoate was more than 0.999. To establish stability-indicating capability of the method, drug product was subjected to the stress conditions of acid, base, oxidative, hydrolytic, thermal and photolytic degradation. The degradation products were well resolved from desloratadine and sodium benzoate. The developed method was validated as per international ICH guidelines with respect to specificity, linearity, LOD, LOQ, accuracy, precision and robustness.

  18. Development and Validation of a Stability-indicating Reversed-phase UPLC-UV Method for the Assay of Imidacloprid and Estimation of its Related Compounds.

    PubMed

    Tian, Jingzhi; Rustum, Abu

    2018-02-01

    Imidacloprid is used as an active pharmaceutical ingredient (API) in veterinary drugs to control fleas and ticks for dogs and cats. Here we are reporting for the first time a validated stability-indicating reversed-phase UPLC-UV method for the assay of imidacloprid and estimation of its related compounds. The stability-indicating capability of this method has been demonstrated by a forced degradation study. All related compounds including processing impurities, imidacloprid API and degradates from stressed samples were well separated from each other. Structures of major degradates from forced degradation study were elucidated through UPLC-MS/MS and key degradation pathways were proposed from the proposed chemical structures of major degradates. The UPLC-UV method is carried out using an HSS T3 column (C18, 2.1 × 30 mm, 1.8 μm particle size) maintained at 30°C with mobile phase A (0.05% v/v of phosphoric acid in water) and mobile phase B (methanol/acetonitrile 75/25 v/v). Analytes are separated by a gradient elution and detected at 270 nm. The UPLC method is green and fast with only 6.5 min run time and about 3.5 ml mobile phase consumption for each sample analysis. The UPLC-UV method was validated according to ICH guidelines. © The Author 2017. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.

  19. Validation of a stability-indicating hydrophilic interaction liquid chromatographic method for the quantitative determination of vitamin k3 (menadione sodium bisulfite) in injectable solution formulation.

    PubMed

    Ghanem, Mashhour M; Abu-Lafi, Saleh A; Hallak, Hussein O

    2013-01-01

    A simple, specific, accurate, and stability-indicating method was developed and validated for the quantitative determination of menadione sodium bisulfite in the injectable solution formulation. The method is based on zwitterionic hydrophilic interaction liquid chromatography (ZIC-HILIC) coupled with a photodiode array detector. The desired separation was achieved on the ZIC-HILIC column (250 mm × 4.6 mm, 5 μm) at 25°C temperature. The optimized mobile phase consisted of an isocratic solvent mixture of 200mM ammonium acetate (NH4AC) solution and acetonitrile (ACN) (20:80; v/v) pH-adjusted to 5.7 by glacial acetic acid. The mobile phase was fixed at 0.5 ml/min and the analytes were monitored at 261 nm using a photodiode array detector. The effects of the chromatographic conditions on the peak retention, peak USP tailing factor, and column efficiency were systematically optimized. Forced degradation experiments were carried out by exposing menadione sodium bisulfite standard and the injectable solution formulation to thermal, photolytic, oxidative, and acid-base hydrolytic stress conditions. The degradation products were well-resolved from the main peak and the excipients, thus proving that the method is a reliable, stability-indicating tool. The method was validated as per ICH and USP guidelines (USP34/NF29) and found to be adequate for the routine quantitative estimation of menadione sodium bisulfite in commercially available menadione sodium bisulfite injectable solution dosage forms.

  20. Facultative Stabilization Pond: Measuring Biological Oxygen Demand using Mathematical Approaches

    NASA Astrophysics Data System (ADS)

    Wira S, Ihsan; Sunarsih, Sunarsih

    2018-02-01

    Pollution is a man-made phenomenon. Some pollutants which discharged directly to the environment could create serious pollution problems. Untreated wastewater will cause contamination and even pollution on the water body. Biological Oxygen Demand (BOD) is the amount of oxygen required for the oxidation by bacteria. The higher the BOD concentration, the greater the organic matter would be. The purpose of this study was to predict the value of BOD contained in wastewater. Mathematical modeling methods were chosen in this study to depict and predict the BOD values contained in facultative wastewater stabilization ponds. Measurements of sampling data were carried out to validate the model. The results of this study indicated that a mathematical approach can be applied to predict the BOD contained in the facultative wastewater stabilization ponds. The model was validated using Absolute Means Error with 10% tolerance limit, and AME for model was 7.38% (< 10%), so the model is valid. Furthermore, a mathematical approach can also be applied to illustrate and predict the contents of wastewater.

  1. Identification, preparation and UHPLC determination of process-related impurity in zolmitriptan.

    PubMed

    Douša, Michal; Gibala, Petr; Rádl, Stanislav; Klecán, Ondřej; Mandelová, Zuzana; Břicháč, Jiří; Pekárek, Tomáš

    2012-01-25

    A new impurity was detected and determined using gradient ion-pair UHPLC method with UV detection in zolmitriptan (ZOL). Using MS, NMR and IR study the impurity was identified as (4S,4'S)-4,4'-(2,2'-(4-(dimethylamino)butane-1,1-diyl)bis(3-(2-(dimethylamino) ethyl)-1H-indole-5,2-diyl))bis(methylene)di(oxazolidin-2-one) (ZOL-dimer). The standard of ZOL-dimer was consequently prepared via organic synthesis followed by semipreparative HPLC purification. The UHPLC method was optimized in order to selectively detect and quantify other known and unknown process-related impurities and degradation products of ZOL as well. The presented method which was validated with respect to linearity, accuracy, precision and selectivity has an advantage of a very quick UHPLC chromatographic separation (less than 7 min including re-equilibration time) and therefore is highly suitable for routine analysis of related substances and stability studies of ZOL. Copyright © 2011 Elsevier B.V. All rights reserved.

  2. Optimization of a Precolumn OPA Derivatization HPLC Assay for Monitoring of l-Asparagine Depletion in Serum during l-Asparaginase Therapy.

    PubMed

    Zhang, Mei; Zhang, Yong; Ren, Siqi; Zhang, Zunjian; Wang, Yongren; Song, Rui

    2018-06-06

    A method for monitoring l-asparagine (ASN) depletion in patients' serum using reversed-phase high-performance liquid chromatography with precolumn o-phthalaldehyde and ethanethiol (ET) derivatization is described. In order to improve the signal and stability of analytes, several important factors including precipitant reagent, derivatization conditions and detection wavelengths were optimized. The recovery of the analytes in biological matrix was the highest when 4% sulfosalicylic acid (1:1, v/v) was used as a precipitant reagent. Optimal fluorescence detection parameters were determined as λex = 340 nm and λem = 444 nm for maximal signal. The signal of analytes was the highest when the reagent ET and borate buffer of pH 9.9 were used in the derivatization solution. And the corresponding derivative products were stable up to 19 h. The validated method had been successfully applied to monitor ASN depletion and l-aspartic acid, l-glutamine, l-glutamic acid levels in pediatric patients during l-asparaginase therapy.

  3. Comparative pharmacokinetics study of three anthraquinones in rat plasma after oral administration of Radix et Rhei Rhizoma extract and Dahuang Fuzi Tang by high performance liquid chromatography-mass spectrometry.

    PubMed

    Li, Huan; Guo, Hui; Wu, Li; Zhang, Yongxin; Chen, Juan; Liu, Xiao; Cai, Hao; Zhang, Kewei; Cai, Baochang

    2013-03-25

    A specific and sensitive high performance liquid chromatography-mass spectrometric (HPLC-MS) method has been developed and validated for simultaneous determination of three anthraquinones of rhein, aloe-emodin and emodin in rat plasma after oral administration of Radix et Rhei Rhizoma extract and Dahuang Fuzi Tang. The analytes were separated on a Kromaisl(®) C(18) column within a total running time of 12min with a mobile phase of methanol:ammonium acetate (3mM) (75:25, v/v). The calibration curves for all the anthraquinones showed good linearity in the measured range with correlation coefficient (r) higher than 0.9978. The precision, accuracy, recovery and stability were deemed acceptable. The method was successfully applied to the comparative pharmacokinetics study of the anthraquinones in rat plasma after oral administration of Radix et Rhei Rhizoma extract and Dahuang Fuzi Tang. Copyright © 2012 Elsevier B.V. All rights reserved.

  4. Determination of MDMA, MDA, MDEA and MBDB in oral fluid using high performance liquid chromatography with native fluorescence detection.

    PubMed

    Concheiro, Marta; de Castro, Ana; Quintela, Oscar; López-Rivadulla, Manuel; Cruz, Angelines

    2005-06-10

    This paper describes the analytical methodology for the determination of MDMA, MDA, MDEA and MBDB in oral fluid. After a liquid-liquid extraction, the analysis was carried out by high performance liquid chromatography (HPLC), with fluorescence detection. The detector wavelength was fixed at 285 nm for excitation and 320 nm for emission. The mobile phase, a mixture of phosphate buffer (pH=5) and acetonitrile (75:25), and the column, Kromasil 100 C8 5 microm 250 mm x 4.6mm, allowed good separation of the compounds in an isocratic mode in only 10 min. The method was validated and showed good limits of detection (2 ng/mL) and quantitation (10 ng/mL) for all the amphetamine derivatives. No interfering substances were detected. A stability study of these compounds in oral fluid stored at three different temperatures (-18, 4 and 20 degrees C) over 10 weeks was conducted, showing a time-dependent degradation of the four compounds.

  5. Development and validation of an HPLC-MS/MS method to determine clopidogrel in human plasma. Use of incurred samples to test back-conversion.

    PubMed

    Silvestro, Luigi; Gheorghe, Mihaela Cristina; Tarcomnicu, Isabela; Savu, Silviu; Savu, Simona Rizea; Iordachescu, Adriana; Dulea, Constanta

    2010-11-15

    Quantitative methods using LC-MS/MS allow achievement of adequate sensitivity for pharmacokinetic studies with clopidogrel; three such methods, with LLOQs as low as 5 pg/mL, were developed and fully validated according to the well established FDA 2001 guidelines. The chromatographic separations were performed on reversed phase columns Ascentis RP-Amide (15 cm x 2.1 mm, 5 μm), Ascentis Express C8 (10 cm x 2.1 mm, 2.7 μm) and Ascentis Express RP Amide (10 cm x 2.1 mm, 2.7 μm), respectively. Positive electrospray ionization in MRM mode was employed for the detection and a deuterated analogue (d3-clopidogrel) was used as internal standard. Linearity, precision, extraction recovery, matrix effects and stability tests on blank plasma spiked with clopidogrel and stored in different conditions met the acceptance criteria. During the analysis of the real samples from the first pharmacokinetic study, a significant increase (>100%) of the measured clopidogrel concentrations in the extracts kept in the autosampler at 10 °C was observed. Investigations led to the conclusion that most probably a back-conversion of one or more of the clopidogrel metabolites is occurring. The next methods were optimized in order to minimize this back-conversion. After a series of experiments, the adjustment of the sample preparation (e.g. processing at low temperature and introducing a clean-up step on Supelco HybridSPE-Precipitation cartridges) has proven to be the most effective in order to improve the stability of the extracts. Incurred samples of real subjects were successfully used in the validation of the last two analytical methods to evaluate the back-conversion, while tests using only the known metabolites could not detect this important problem. Copyright © 2010 Elsevier B.V. All rights reserved.

  6. Analysis of Free Amino Acids in Different Extracts of Orthosiphon stamineus Leaves by High-Performance Liquid Chromatography Combined with Solid-Phase Extraction.

    PubMed

    Shafaei, Armaghan; Halim, Nor Hidayah Ab; Zakaria, Norhidayah; Ismail, Zhari

    2017-10-01

    Orthosiphon stamineus (OS) Benth is a medicinal plant and native in Southeast Asia. Previous studies have shown that OS leaves possess antioxidant, cytotoxic, diuretic, antihypertensive, and uricosuric effects. These beneficial effects have been attributed to the presence of primary and secondary metabolites such as polyphenols, amino acids, and flavonoids. To develop and validate an high-performance liquid chromatography (HPLC)-diode array detector (DAD) method combined with solid-phase extraction that involves precolumn derivatization with O -phthaladehyde for simultaneous analysis of free amino acids in OS leaves extracts. OS leaves were extracted with water (OS-W), ethanol (OS-E), methanol (OS-M), 50% ethanol (OS-EW), and 50% methanol (OS-MW). The extracts were treated by C18 cartridge before derivatization, resulting in great improvement of separation by Zorbox Eclipse XDB-C 18 column. The HPLC-DAD method was successfully developed and validated for analyzing the contents of free amino acids in OS extracts. The results showed that l-aspartic acid with 0.93 ± 0.01 nmol/mg was the major free amino acid in OS-W extract. However, in OS-E, OS-M, OS-EW, and OS-MW, l-glutamic acid with 3.53 ± 0.16, 2.17 ± 0.10, 4.01 ± 0.12, and 2.49 ± 0.12 nmol/mg, respectively, was the major free amino acid. Subsequently, l-serine, which was detected in OS-W, OS-E, and OS-M, was the minor free amino acid with 0.33 ± 0.02, 0.12 ± 0.01, and 0.06 ± 0.01 nmol/mg, respectively. However, l-threonine with 0.26 ± 0.02 and 0.19 ± 0.08 nmol/mL in OS-EW and OS-MW, respectively, had the lowest concentration compared with other amino acid components. All validation parameters of the developed method indicate that the method is reliable and efficient to simultaneously determine the free amino acids content for routine analysis of OS extracts. The HPLC-DAD method combined with solid phase extraction was successfully developed and validated for simultaneous determination and quantification of 17 free amino acids in Orthosiphon stamineus (OS) Benth extractsOS extracts were found to be rich in free amino acid contentL-aspartic acid was the major free amino acid in OS water extract while, in OS ethanol, methanol, 50% ethanol and 50% methanol extracts, L-glutamic acid was the major free amino acidL-serine was the minor free amino acid in OS water, ethanol and methanol extracts while, in OS 50% ethanol and 50% methanol extracts, L-threonine had the lowest concentration compared to other amino acid components. Abbreviations used: HPLC-DAD: High-Performance Liquid Chromatography with Diode-Array Detection, OS: Orthosiphon stamineus , OS-W: Orthosiphon stamineus water extract, OS-E: Orthosiphon stamineus ethanol extract, OS-M: Orthosiphon stamineus methanol extract, OS-EW: Orthosiphon stamineus 50% ethanol extract, OS-MW: Orthosiphon stamineus 50% methanol extract, OPA: O-phthaladehyde , SPE: Solid Phase Extraction, UV: Ultraviolet, LOD: Limit of Detection, LOQ: Limit of Quantification, RSD: Relative Standard Deviation.

  7. Nursing Intensive-Care Satisfaction Scale [NICSS]: Development and validation of a patient-centred instrument.

    PubMed

    Romero-García, Marta; de la Cueva-Ariza, Laura; Benito-Aracil, Llucia; Lluch-Canut, Teresa; Trujols-Albet, Joan; Martínez-Momblan, Maria Antonia; Juvé-Udina, Maria-Eulàlia; Delgado-Hito, Pilar

    2018-06-01

    The aim of this study was to develop and validate the Nursing Intensive-Care Satisfaction Scale to measures satisfaction with nursing care from the critical care patient's perspective. Instruments that measure satisfaction with nursing cares have been designed and validated without taking the patient's perspective into consideration. Despite the benefits and advances in measuring satisfaction with nursing care, none instrument is specifically designed to assess satisfaction in intensive care units. Instrument development. The population were all discharged patients (January 2013 - January 2015) from three Intensive Care Units of a third level hospital (N = 200). All assessment instruments were given to discharged patients and 48 hours later, to analyse the temporal stability, only the questionnaire was given again. The validation process of the scale included the analysis of internal consistency, temporal stability; validity of construct through a confirmatory factor analysis; and criterion validity. Reliability was 0.95. The intraclass correlation coefficient for the total scale was 0.83 indicating a good temporal stability. Construct validity showed an acceptable fit and factorial structure with four factors, in accordance with the theoretical model, being Consequences factor the best correlated with other factors. Criterion validity, presented a correlation between low and high (range: 0.42-0.68). The scale has been designed and validated incorporating the perspective of critical care patients. Thanks to its reliability and validity, this questionnaire can be used both in research and in clinical practice. The scale offers a possibility to assess and develop interventions to improve patient satisfaction with nursing care. © 2018 John Wiley & Sons Ltd.

  8. A New Symptom Model for Autism Cross-Validated in an Independent Sample

    ERIC Educational Resources Information Center

    Boomsma, A.; Van Lang, N. D. J.; De Jonge, M. V.; De Bildt, A. A.; Van Engeland, H.; Minderaa, R. B.

    2008-01-01

    Background: Results from several studies indicated that a symptom model other than the DSM triad might better describe symptom domains of autism. The present study focused on a) investigating the stability of a new symptom model for autism by cross-validating it in an independent sample and b) examining the invariance of the model regarding three…

  9. Qualitative and quantitative determination of yohimbine in authentic yohimbe bark and in commercial aphrodisiacs by HPLC-UV-API/ MS methods.

    PubMed

    Zanolari, Boris; Ndjoko, Karine; Ioset, Jean-Robert; Marston, Andrew; Hostettmann, Kurt

    2003-01-01

    The development and validation of a rapid qualitative and quantitative method based on an HPLC-UV-MS technique with atmospheric pressure chemical ionisation and electrospray ionisation for the analysis of yohimbine in a number of commercial aphrodisiac products is reported. HPLC with multiple-stage mass spectrometry experiments allowed the identification of the target compound and increased the selectivity of complex analyses such as those involved with multi-botanical preparations. The precision and the robustness of the method were improved by the use of two internal standards: codeine for UV detection and deuterium-labelled yohimbine for MS detection. Twenty commercial aphrodisiac preparations were analysed and the amount of yohimbine measured and expressed as the maximal dose per day suggested on product labels ranged from 1.32 to 23.16 mg.

  10. DETERMINATION OF VENLAFAXINE, VILAZODONE AND THEIR MAIN ACTIVE METABOLITES IN HUMAN SERUM BY HPLC-DAD AND HPLC-MS.

    PubMed

    Petruczynik, Anna; Wroblewski, Karol; Szultka-Mlynska, Malgorzata; Buszewsk, Boguslaw; Karakula-Juchnowicz, Hanna; Gajewski, Jacek; Morylowska-Topolska, Justyna; Waksmundzka-Hajnosi, Monika

    2017-05-01

    A high performance liquid chromatography (HPLC) method for simultaneous analysis of venlafaxine and its major metabolite 0-desmethylvenlafaxine and vilazodone and its methabolite M10 have been devel- oped and validated. Chromatography was performed on the Phenyl-Hexyl column with mobile phase containing methanol, acetate buffer at pH 3.5 and diethylamine. The application of stationary phase with 7r-7c moieties and mobile phase containing diethylamine as silanol blocker lets to obtain double protection against silanols and thus very high theoretical plate numbers were obtained. The good separation selectivity, good peaks' symmetry and very high systems efficiency for all investigated compounds were obtained in applied chromatographic system. The method is very efficient and suitable for the analysis of investigated drugs and their metabolites in human serum for patients' pharmacotherapy control.

  11. RAPID AND SIMPLIFIED HPLC METHOD WITH UV DETECTION, PH CONTROL AND SELECTIVE DECHLORINATOR FOR CYANURIC ACID ANALYSIS IN WATER

    EPA Science Inventory

    Cyanuric acid (CA) and chloroisocyanurates are commonly used as standard ingredients in formulations for household bleaches, industrial cleansers, dishwasher compounds, general sanitizers, and chlorine stabilizers. They are very well known for preventing the photolytic decomposi...

  12. Assessment of Free Dye in Solutions of Dual-Labeled Antibody Conjugates for In Vivo Molecular Imaging

    PubMed Central

    Aldrich, Melissa B.; Wang, XueJuan; Hart, Amy; Sampath, Lakshmi; Marshall, Milton V.; Sevick-Muraca, Eva M.

    2017-01-01

    PURPOSE Recent preclinical and clinical studies show dyes that excite and fluoresce in the near infrared range may be used for tracking and detecting disease targets in vivo. A method for quantifying free dye molecules in antibody conjugate preparations is required for agent batch release and for translation into the clinic. PROCEDURES Herein, we developed and validated a SDS-PAGE method to determine the percentage of free IRDye 800CW in (DTPA)n-trastuzumab—(IRDye 800)m conjugate sample preparations in which HPLC assessment of free dye was not possible. RESULTS The SDS-PAGE assay was accurate and valid for free IRDye 800CW amounts between 38 and 4 molar percent of total dye. Gel sample preparation reagent affected the specificity of the assay, and lower and upper limits of quantitation and detection were determined. CONCLUSION This method may be applicable to other near infrared dye-conjugated antibody-based imaging agents in which HPLC assessment of purity is not feasible. This validated method for quality assurance will facilitate the translation of dual-labeled antibody conjugates for nuclear and optical imaging. PMID:20458634

  13. RP-HPLC Method Development and Validation for Determination of Eptifibatide Acetate in Bulk Drug Substance and Pharmaceutical Dosage Forms.

    PubMed

    Bavand Savadkouhi, Maryam; Vahidi, Hossein; Ayatollahi, Abdul Majid; Hooshfar, Shirin; Kobarfard, Farzad

    2017-01-01

    A new, rapid, economical and isocratic reverse phase high performance liquid chromatography (RP-HPLC) method was developed for the determination of eptifibatide acetate, a small synthetic antiplatelet peptide, in bulk drug substance and pharmaceutical dosage forms. The developed method was validated as per of ICH guidelines. The chromatographic separation was achieved isocratically on C18 column (150 x 4.60 mm i.d., 5 µM particle size) at ambient temperature using acetonitrile (ACN), water and trifluoroacetic acid (TFA) as mobile phase at flow rate of 1 mL/min and UV detection at 275 nm. Eptifibatide acetate exhibited linearity over the concentration range of 0.15-2 mg/mL (r 2 =0.997) with limit of detection of 0.15 mg/mL The accuracy of the method was 96.4-103.8%. The intra-day and inter-day precision were between 0.052% and 0.598%, respectively. The present successfully validated method with excellent selectivity, linearity, sensitivity, precision and accuracy was applicable for the assay of eptifibatide acetate in bulk drug substance and pharmaceutical dosage forms.

  14. Determination of catechins and caffeine in camillia sinensis raw materials, extracts, and dietary supplements by HPLC-uv: single-laboratory validation.

    PubMed

    Roman, Mark C

    2013-01-01

    A rapid method has been developed to quantify seven catechins and caffeine in green tea (Camillia sinensis) raw material and powdered extract, and dietary supplements containing green tea extract. The method utilizes RP HPLC with a phenyl-based stationary phase and gradient elution. Detection is by UV absorbance. The total run time, including column re-equilibration, is 13 min. Single-laboratory validation (SLV) has been performed on the method to determine the repeatability, accuracy, selectivity, LOD, LOQ, ruggedness, and linearity for (+)-catechin, (-)-epicatechin, (-)-epicatechin gallate, (-)-epigallocatechin, (-)-gallocatechin gallate, (-)-epigallocatechin gallate, and (+)-gallocatechin, as well as caffeine. Repeatability precision and recovery results met AOAC guidelines for SLV studies for all catechins and caffeine down to a level of approximately 20 mg/g. Finished products containing high concentrations of minerals require the use of EDTA to prevent decomposition of the catechins.

  15. Comparison on extraction yield of sennoside A and sennoside B from senna (Cassia angustifolia) using conventional and non conventional extraction techniques and their quantification using a validated HPLC-PDA detection method.

    PubMed

    Dhanani, Tushar; Singh, Raghuraj; Reddy, Nagaraja; Trivedi, A; Kumar, Satyanshu

    2017-05-01

    Senna is an important medicinal plant and is used in many Ayurvedic formulations. Dianthraquinone glucosides are the main bioactive phytochemicals present in leaves and pods of senna. The extraction efficiency in terms of yield and composition of the extract of senna prepared using both conventional (cold percolation at room temperature and refluxing) and non conventional (ultrasound and microwave assisted solvent extraction as well as supercritical fluid extraction) techniques were compared in the present study. Also a rapid reverse phase HPLC-PDA detection method was developed and validated for the simultaneous determination of sennoside A and sennoside B in the different extracts of senna leaves. Ultrasound and microwave assisted solvent extraction techniques were more effective in terms of yield and composition of the extracts compared to cold percolation at room temperature and refluxing methods of extraction.

  16. Simultaneous analysis of coccidiostats and sulfonamides in non-target feed by HPLC-MS/MS and validation following the Commission Decision 2002/657/EC.

    PubMed

    Gavilán, Rosa Elvira; Nebot, Carolina; Patyra, Ewelina; Miranda, Jose Manuel; Franco, Carlos Manuel; Cepeda, Alberto

    2018-05-02

    Taking into consideration the maximum level for coccidiostats included in the European Regulation 574/2011 and the fact that the presence of residues of sulfonamides in non-target feed is forbidden, the aim of this article is to present an analytical method based on HPLC-MS/MS for the identification and quantification of sulfonamides and coccidiostats in non-target feeds. The method was validated following Decision 2002/657/EC and recovery, repeatability, and reproducibility were within the limits stablished in the Decision. For coccidiostats, the decision limit and detection capability were calculated for the different species taking into account the maximum level allowed in Regulation 574/2011. The applicability of the method was investigated in 50 feed samples collected from dairy farms, 50 obtained from feed mills, and 10 interlaboratory feed samples.

  17. Collaborative trial validation study of two methods, one based on high performance liquid chromatography-tandem mass spectrometry and on gas chromatography-mass spectrometry for the determination of acrylamide in bakery and potato products.

    PubMed

    Wenzl, Thomas; Karasek, Lubomir; Rosen, Johan; Hellenaes, Karl-Erik; Crews, Colin; Castle, Laurence; Anklam, Elke

    2006-11-03

    A European inter-laboratory study was conducted to validate two analytical procedures for the determination of acrylamide in bakery ware (crispbreads, biscuits) and potato products (chips), within a concentration range from about 20 microg/kg to about 9000 microgg/kg. The methods are based on gas chromatography-mass spectrometry (GC-MS) of the derivatised analyte and on high performance liquid chromatography-tandem mass spectrometry (HPLC-MS/MS) of native acrylamide. Isotope dilution with isotopically labelled acrylamide was an integral part of both methods. The study was evaluated according to internationally accepted guidelines. The performance of the HPLC-MS/MS method was found to be superior to that of the GC-MS method and to be fit-for-the-purpose.

  18. A Novel HPLC Method for the Concurrent Analysis and Quantitation of Seven Water-Soluble Vitamins in Biological Fluids (Plasma and Urine): A Validation Study and Application

    PubMed Central

    Grotzkyj Giorgi, Margherita; Howland, Kevin; Martin, Colin; Bonner, Adrian B.

    2012-01-01

    An HPLC method was developed and validated for the concurrent detection and quantitation of seven water-soluble vitamins (C, B1, B2, B5, B6, B9, B12) in biological matrices (plasma and urine). Separation was achieved at 30°C on a reversed-phase C18-A column using combined isocratic and linear gradient elution with a mobile phase consisting of 0.01% TFA aqueous and 100% methanol. Total run time was 35 minutes. Detection was performed with diode array set at 280 nm. Each vitamin was quantitatively determined at its maximum wavelength. Spectral comparison was used for peak identification in real samples (24 plasma and urine samples from abstinent alcohol-dependent males). Interday and intraday precision were <4% and <7%, respectively, for all vitamins. Recovery percentages ranged from 93% to 100%. PMID:22536136

  19. A novel HPLC method for the concurrent analysis and quantitation of seven water-soluble vitamins in biological fluids (plasma and urine): a validation study and application.

    PubMed

    Giorgi, Margherita Grotzkyj; Howland, Kevin; Martin, Colin; Bonner, Adrian B

    2012-01-01

    An HPLC method was developed and validated for the concurrent detection and quantitation of seven water-soluble vitamins (C, B(1), B(2), B(5), B(6), B(9), B(12)) in biological matrices (plasma and urine). Separation was achieved at 30°C on a reversed-phase C18-A column using combined isocratic and linear gradient elution with a mobile phase consisting of 0.01% TFA aqueous and 100% methanol. Total run time was 35 minutes. Detection was performed with diode array set at 280 nm. Each vitamin was quantitatively determined at its maximum wavelength. Spectral comparison was used for peak identification in real samples (24 plasma and urine samples from abstinent alcohol-dependent males). Interday and intraday precision were <4% and <7%, respectively, for all vitamins. Recovery percentages ranged from 93% to 100%.

  20. Application of electrolysis for inactivation of an antiviral drug that is one of possible selection pressure to drug-resistant influenza viruses.

    PubMed

    Kobayashi, Toyohide; Hirose, Jun; Wu, Hong; Sano, Kouichi; Katsumata, Takahiro; Tsujibo, Hiroshi; Nakano, Takashi

    2013-12-01

    The recent development of antiviral drugs has led to concern that the release of the chemicals in surface water due to expanded medical use could induce drug-resistant mutant viruses in zoonosis. Many researchers have noted that the appearance of an oseltamivir (Tamiflu(®))-resistant avian influenza mutant virus, which may spread to humans, could be induced by oseltamivir contamination of surface water. Although past studies have reported electrolysis as a possible method for degradation of antineoplastics and antibacterials in water, the validity of the method for treatment of antiviral drugs is unknown. In this study, electrolysis was used to degrade an antiviral prodrug, oseltamivir, and a stable active form, oseltamivir carboxylate, and the degradation process was monitored with HPLC-UV and the neuraminidase inhibitory assay. HPLC-UV-detectable oseltamivir and oseltamivir carboxylate were decomposed by electrolysis within 60 min, and inhibitory activity of neuraminidase decreased below the detection limit of the assay used. Cytotoxic and genotoxic activity were not detected in electrolyzed fluid. These results indicate that electrolysis is a possible treatment for inactivation of the antiviral drug oseltamivir. Copyright © 2013 Elsevier B.V. All rights reserved.

Top