Sample records for validation plan svvp

  1. RELAP-7 Software Verification and Validation Plan - Requirements Traceability Matrix (RTM) Part 2: Code Assessment Strategy, Procedure, and RTM Update

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Yoo, Jun Soo; Choi, Yong Joon; Smith, Curtis Lee

    2016-09-01

    This document addresses two subjects involved with the RELAP-7 Software Verification and Validation Plan (SVVP): (i) the principles and plan to assure the independence of RELAP-7 assessment through the code development process, and (ii) the work performed to establish the RELAP-7 assessment plan, i.e., the assessment strategy, literature review, and identification of RELAP-7 requirements. Then, the Requirements Traceability Matrices (RTMs) proposed in previous document (INL-EXT-15-36684) are updated. These RTMs provide an efficient way to evaluate the RELAP-7 development status as well as the maturity of RELAP-7 assessment through the development process.

  2. Some guidance on preparing validation plans for the DART Full System Models.

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Gray, Genetha Anne; Hough, Patricia Diane; Hills, Richard Guy

    2009-03-01

    Planning is an important part of computational model verification and validation (V&V) and the requisite planning document is vital for effectively executing the plan. The document provides a means of communicating intent to the typically large group of people, from program management to analysts to test engineers, who must work together to complete the validation activities. This report provides guidelines for writing a validation plan. It describes the components of such a plan and includes important references and resources. While the initial target audience is the DART Full System Model teams in the nuclear weapons program, the guidelines are generallymore » applicable to other modeling efforts. Our goal in writing this document is to provide a framework for consistency in validation plans across weapon systems, different types of models, and different scenarios. Specific details contained in any given validation plan will vary according to application requirements and available resources.« less

  3. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Chen, X; Wang, J; Hu, W

    Purpose: The Varian RapidPlan™ is a commercial knowledge-based optimization process which uses a set of clinically used treatment plans to train a model that can predict individualized dose-volume objectives. The purpose of this study is to evaluate the performance of RapidPlan to generate intensity modulated radiation therapy (IMRT) plans for cervical cancer. Methods: Totally 70 IMRT plans for cervical cancer with varying clinical and physiological indications were enrolled in this study. These patients were all previously treated in our institution. There were two prescription levels usually used in our institution: 45Gy/25 fractions and 50.4Gy/28 fractions. 50 of these plans weremore » selected to train the RapidPlan model for predicting dose-volume constraints. After model training, this model was validated with 10 plans from training pool(internal validation) and additional other 20 new plans(external validation). All plans used for the validation were re-optimized with the original beam configuration and the generated priorities from RapidPlan were manually adjusted to ensure that re-optimized DVH located in the range of the model prediction. DVH quantitative analysis was performed to compare the RapidPlan generated and the original manual optimized plans. Results: For all the validation cases, RapidPlan based plans (RapidPlan) showed similar or superior results compared to the manual optimized ones. RapidPlan increased the result of D98% and homogeneity in both two validations. For organs at risk, the RapidPlan decreased mean doses of bladder by 1.25Gy/1.13Gy (internal/external validation) on average, with p=0.12/p<0.01. The mean dose of rectum and bowel were also decreased by an average of 2.64Gy/0.83Gy and 0.66Gy/1.05Gy,with p<0.01/ p<0.01and p=0.04/<0.01 for the internal/external validation, respectively. Conclusion: The RapidPlan model based cervical cancer plans shows ability to systematically improve the IMRT plan quality. It suggests that RapidPlan has great potential to make the treatment planning process more efficient.« less

  4. MISR - Science Data Validation Plan

    NASA Technical Reports Server (NTRS)

    Conel, J.; Ledeboer, W.; Ackerman, T.; Marchand, R.; Clothiaux, E.

    2000-01-01

    This Science Data Validation Plan describes the plans for validating a subset of the Multi-angle Imaging SpectroRadiometer (MISR) Level 2 algorithms and data products and supplying top-of-atmosphere (TOA) radiances to the In-flight Radiometric Calibration and Characterization (IFRCC) subsystem for vicarious calibration.

  5. Development and Initial Validation of an Instrument for Human Capital Planning

    ERIC Educational Resources Information Center

    Zula, Kenneth J.; Chermack, Thomas J.

    2008-01-01

    This article reports on development and validation of an instrument for use in human capital approaches for organizational planning. The article describes use of a team of subject matter experts in developing a measure of human capital planning, and use of exploratory factor analysis techniques to validate the resulting instrument. These data were…

  6. Development of Level 2 Calibration and Validation Plans for GOES-R; What is a RIMP?

    NASA Technical Reports Server (NTRS)

    Kopp, Thomas J.; Belsma, Leslie O.; Mollner, Andrew K.; Sun, Ziping; Deluccia, Frank

    2017-01-01

    Calibration and Validation (CalVal) plans for Geostationary Operational Environmental Satellite version R (GOES-R) Level 2 (L2) products were documented via Resource, Implementation, and Management Plans (RIMPs) for all of the official L2 products required from the GOES-R Advanced Baseline Imager (ABI). In 2015 the GOES-R program decided to replace the typical CalVal plans with RIMPs that covered, for a given L2 product, what was required from that product, how it would be validated, and what tools would be used to do so. Similar to Level 1b products, the intent was to cover the full spectrum of planning required for the CalVal of L2 ABI products. Instead of focusing on step-by-step procedures, the RIMPs concentrated on the criteria for each stage of the validation process (Beta, Provisional, and Full Validation) and the many elements required to prove when each stage was reached.

  7. NASA sea ice and snow validation plan for the Defense Meteorological Satellite Program special sensor microwave/imager

    NASA Technical Reports Server (NTRS)

    Cavalieri, Donald J. (Editor); Swift, Calvin T. (Editor)

    1987-01-01

    This document addresses the task of developing and executing a plan for validating the algorithm used for initial processing of sea ice data from the Special Sensor Microwave/Imager (SSMI). The document outlines a plan for monitoring the performance of the SSMI, for validating the derived sea ice parameters, and for providing quality data products before distribution to the research community. Because of recent advances in the application of passive microwave remote sensing to snow cover on land, the validation of snow algorithms is also addressed.

  8. The Challenge of Grounding Planning in Simulation with an Interactive Model Development Environment

    NASA Technical Reports Server (NTRS)

    Clement, Bradley J.; Frank, Jeremy D.; Chachere, John M.; Smith, Tristan B.; Swanson, Keith J.

    2011-01-01

    A principal obstacle to fielding automated planning systems is the difficulty of modeling. Physical systems are modeled conventionally based on specification documents and the modeler's understanding of the system. Thus, the model is developed in a way that is disconnected from the system's actual behavior and is vulnerable to manual error. Another obstacle to fielding planners is testing and validation. For a space mission, generated plans must be validated often by translating them into command sequences that are run in a simulation testbed. Testing in this way is complex and onerous because of the large number of possible plans and states of the spacecraft. Though, if used as a source of domain knowledge, the simulator can ease validation. This paper poses a challenge: to ground planning models in the system physics represented by simulation. A proposed, interactive model development environment illustrates the integration of planning and simulation to meet the challenge. This integration reveals research paths for automated model construction and validation.

  9. SU-E-T-97: An Analysis of Knowledge Based Planning for Stereotactic Body Radiation Therapy of the Spine

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Foy, J; Marsh, R; Owen, D

    2015-06-15

    Purpose: Creating high quality SBRT treatment plans for the spine is often tedious and time consuming. In addition, the quality of treatment plans can vary greatly between treatment facilities due to inconsistencies in planning methods. This study investigates the performance of knowledge-based planning (KBP) for spine SBRT. Methods: Treatment plans were created for 28 spine SBRT patients. Each case was planned to meet strict dose objectives and guidelines. After physician and physicist approval, the plans were added to a custom model in a KBP system (RapidPlan, Varian Eclipse v13.5). The model was then trained to be able to predict estimatedmore » DVHs and provide starting objective functions for future patients based on both generated and manual objectives. To validate the model, ten additional spine SBRT cases were planned manually as well as using the model objectives. Plans were compared based on planning time and quality (ability to meet the plan objectives, including dose metrics and conformity). Results: The average dose to the spinal cord and the cord PRV differed between the validation and control plans by <0.25% demonstrating iso-toxicity. Six out of 10 validation plans met all dose objectives without the need for modifications, and overall, target dose coverage was increased by about 4.8%. If the validation plans did not meet the dose requirements initially, only 1–2 iterations of modifying the planning parameters were required before an acceptable plan was achieved. While manually created plans usually required 30 minutes to 3 hours to create, KBP can be used to create similar quality plans in 15–20 minutes. Conclusion: KBP for spinal tumors has shown to greatly decrease the amount of time required to achieve high quality treatment plans with minimal human intervention and could feasibly be used to standardize plan quality between institutions. Supported by Varian Medical Systems.« less

  10. Knowledge, attitudes, and practice behaviors of oncology advanced practice nurses regarding advanced care planning for patients with cancer.

    PubMed

    Zhou, Guiyun; Stoltzfus, Jill C; Houldin, Arlene D; Parks, Susan M; Swan, Beth Ann

    2010-11-01

    To establish initial reliability and validity of a Web-based survey focused on oncology advanced practice nurses' (APNs') knowledge, attitudes, and practice behaviors regarding advanced care planning, and to obtain preliminary understanding of APNs' knowledge, attitudes, and practice behaviors and perceived barriers to advanced care planning. Descriptive, cross-sectional, pilot survey study. The eastern United States. 300 oncology APNs. Guided by the Theory of Planned Behavior, a knowledge, attitudes, and practice behaviors survey was developed and reviewed for content validity. The survey was distributed to 300 APNs via e-mail and sent again to the 89 APNs who responded to the initial survey. Exploratory factor analysis was used to examine the construct validity and test-retest reliability of the survey's attitudinal and practice behavior portions. Respondents' demographics, knowledge, attitudes, practice behaviors, and perceived barriers to advanced care planning practice. Exploratory factor analysis yielded a five-factor solution from the survey's attitudes and practice behavior portions with internal consistency using Cronbach alpha. Respondents achieved an average of 67% correct answers in the 12-item knowledge section and scored positively in attitudes toward advanced care planning. Their practice behavior scores were marginally positive. The most common reported barriers were from patients' and families' as well as physicians' reluctance to discuss advanced care planning. The attitudinal and practice behaviors portions of the survey demonstrated preliminary construct validity and test-retest reliability. Regarding advanced care planning, respondents were moderately knowledgeable, but their advanced care planning practice was not routine. Validly assessing oncology APNs' knowledge, attitudes, and practice behaviors regarding advanced care planning will enable more tailored approaches to improve end-of-life care outcomes.

  11. 9 CFR 381.22 - Conditions for receiving inspection.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... have conducted a hazard analysis and developed and validated a HACCP plan, in accordance with §§ 417.2... exceed 90 days, during which period the establishment must validate its HACCP plan. (c) Before producing... developed a HACCP plan applicable to that product in accordance with § 417.2 of this chapter. During a...

  12. 9 CFR 381.22 - Conditions for receiving inspection.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... have conducted a hazard analysis and developed and validated a HACCP plan, in accordance with §§ 417.2... exceed 90 days, during which period the establishment must validate its HACCP plan. (c) Before producing... developed a HACCP plan applicable to that product in accordance with § 417.2 of this chapter. During a...

  13. RELAP-7 Software Verification and Validation Plan: Requirements Traceability Matrix (RTM) Part 1 – Physics and numerical methods

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Choi, Yong Joon; Yoo, Jun Soo; Smith, Curtis Lee

    2015-09-01

    This INL plan comprehensively describes the Requirements Traceability Matrix (RTM) on main physics and numerical method of the RELAP-7. The plan also describes the testing-based software verification and validation (SV&V) process—a set of specially designed software models used to test RELAP-7.

  14. The development and validation of the advance care planning questionnaire in Malaysia.

    PubMed

    Lai, Pauline Siew Mei; Mohd Mudri, Salinah; Chinna, Karuthan; Othman, Sajaratulnisah

    2016-10-18

    Advance care planning is a voluntary process whereby individual preferences, values and beliefs are used to aid a person in planning for end-of-life care. Currently, there is no local instrument to assess an individual's awareness and attitude towards advance care planning. This study aimed to develop an Advance Care Planning Questionnaire and to determine its validity and reliability among older people in Malaysia. The Advance Care Planning Questionnaire was developed based on literature review. Face and content validity was verified by an expert panel, and piloted among 15 participants. Our study was conducted from October 2013 to February 2014, at an urban primary care clinic in Malaysia. Included were those aged >50 years, who could understand English. A retest was conducted 2 weeks after the first administration. Participants from the pilot study did not encounter any problems in answering the Advance Care Planning Questionnaire. Hence, no further modifications were made. Flesch reading ease was 71. The final version of the Advance Care Planning Questionnaire consists of 66 items: 30 items were measured on a nominal scale, whilst 36 items were measured on a Likert-like scale; of which we were only able to validate 22 items, as the remaining 14 items were descriptive in nature. A total of 245 eligible participants were approached; of which 230 agreed to participate (response rate = 93.9 %). Factor analysis on the 22 items measured on a Likert-scale revealed four domains: "feelings regarding advance care planning", "justifications for advance care planning", "justifications for not having advance care planning: fate and religion", and "justifications for not having advance care planning: avoid thinking about death". The Cronbach's alpha values for items each domain ranged from 0.637-0.915. In test-retest, kappa values ranged from 0.738-0.947. The final Advance Care Planning Questionnaire consisted of 63 items and 4 domains. It was found to be a valid and reliable instrument to assess the awareness and attitude of older people in Malaysia towards advance care planning.

  15. Space Technology 5: Changing the Mission Design without Changing the Hardware

    NASA Technical Reports Server (NTRS)

    Carlisle, Candace C.; Webb, Evan H.; Slavin, James A.

    2005-01-01

    The Space Technology 5 (ST-5) Project is part of NASA's New Millennium Program. The validation objectives are to demonstrate the research-quality science capability of the ST-5 spacecraft; to operate the three spacecraft as a constellation; and to design, develop, test and flight-validate three capable micro-satellites with new technologies. A three-month flight demonstration phase is planned, beginning in March 2006. This year, the mission was re-planned for a Pegasus XL dedicated launch into an elliptical polar orbit (instead of the Originally-planned Geosynchronous Transfer Orbit.) The re-plan allows the mission to achieve the same high-level technology validation objectives with a different launch vehicle. The new mission design involves a revised science validation strategy, a new orbit and different communication strategy, while minimizing changes to the ST-5 spacecraft itself. The constellation operations concepts have also been refined. While the system engineers, orbit analysts, and operations teams were re-planning the mission, the implementation team continued to make progress on the flight hardware. Most components have been delivered, and the first spacecraft is well into integration and test.

  16. Adaptation and Validation of the Tower of London Test of Planning and Problem Solving in People with Intellectual Disabilities

    ERIC Educational Resources Information Center

    Masson, J. D.; Dagnan, D.; Evans, J.

    2010-01-01

    Background: There is a need for validated, standardised tools for the assessment of executive functions in adults with intellectual disabilities (ID). This study examines the validity of a test of planning and problem solving (Tower of London) with adults with ID. Method: Participants completed an adapted version of the Tower of London (ToL) while…

  17. Adaptation and validation of the Tower of London test of planning and problem solving in people with intellectual disabilities.

    PubMed

    Masson, J D; Dagnan, D; Evans, J

    2010-05-01

    There is a need for validated, standardised tools for the assessment of executive functions in adults with intellectual disabilities (ID). This study examines the validity of a test of planning and problem solving (Tower of London) with adults with ID. Participants completed an adapted version of the Tower of London (ToL) while day-centre staff completed adaptive function (Adaptive Behaviour Scale - Residential and Community: Second Edition, modified version) and dysexecutive function (DEX-Independent Rater) questionnaires for each participant. Correlation analyses of test and questionnaire variables were undertaken. The adapted ToL has a robust structure and shows significant associations with independent living skills, challenging behaviour and behaviours related to dysexecutive function. The adapted ToL is a valid test for use with people with ID. However, there is also a need to develop other ecologically valid tools based on everyday planning tasks undertaken by people with ID.

  18. Transport aircraft loading and balancing system: Using a CLIPS expert system for military aircraft load planning

    NASA Technical Reports Server (NTRS)

    Richardson, J.; Labbe, M.; Belala, Y.; Leduc, Vincent

    1994-01-01

    The requirement for improving aircraft utilization and responsiveness in airlift operations has been recognized for quite some time by the Canadian Forces. To date, the utilization of scarce airlift resources has been planned mainly through the employment of manpower-intensive manual methods in combination with the expertise of highly qualified personnel. In this paper, we address the problem of facilitating the load planning process for military aircraft cargo planes through the development of a computer-based system. We introduce TALBAS (Transport Aircraft Loading and BAlancing System), a knowledge-based system designed to assist personnel involved in preparing valid load plans for the C130 Hercules aircraft. The main features of this system which are accessible through a convivial graphical user interface, consists of the automatic generation of valid cargo arrangements given a list of items to be transported, the user-definition of load plans and the automatic validation of such load plans.

  19. The validation index: a new metric for validation of segmentation algorithms using two or more expert outlines with application to radiotherapy planning.

    PubMed

    Juneja, Prabhjot; Evans, Philp M; Harris, Emma J

    2013-08-01

    Validation is required to ensure automated segmentation algorithms are suitable for radiotherapy target definition. In the absence of true segmentation, algorithmic segmentation is validated against expert outlining of the region of interest. Multiple experts are used to overcome inter-expert variability. Several approaches have been studied in the literature, but the most appropriate approach to combine the information from multiple expert outlines, to give a single metric for validation, is unclear. None consider a metric that can be tailored to case-specific requirements in radiotherapy planning. Validation index (VI), a new validation metric which uses experts' level of agreement was developed. A control parameter was introduced for the validation of segmentations required for different radiotherapy scenarios: for targets close to organs-at-risk and for difficult to discern targets, where large variation between experts is expected. VI was evaluated using two simulated idealized cases and data from two clinical studies. VI was compared with the commonly used Dice similarity coefficient (DSCpair - wise) and found to be more sensitive than the DSCpair - wise to the changes in agreement between experts. VI was shown to be adaptable to specific radiotherapy planning scenarios.

  20. A comprehensive scoring system to measure healthy community design in land use plans and regulations.

    PubMed

    Maiden, Kristin M; Kaplan, Marina; Walling, Lee Ann; Miller, Patricia P; Crist, Gina

    2017-02-01

    Comprehensive land use plans and their corresponding regulations play a role in determining the nature of the built environment and community design, which are factors that influence population health and health disparities. To determine the level in which a plan addresses healthy living and active design, there is a need for a systematic, reliable and valid method of analyzing and scoring health-related content in plans and regulations. This paper describes the development and validation of a scoring tool designed to measure the strength and comprehensiveness of health-related content found in land use plans and the corresponding regulations. The measures are scored based on the presence of a specific item and the specificity and action-orientation of language. To establish reliability and validity, 42 land use plans and regulations from across the United States were scored January-April 2016. Results of the psychometric analysis indicate the scorecard is a reliable scoring tool for land use plans and regulations related to healthy living and active design. Intraclass correlation coefficients (ICC) scores showed strong inter-rater reliability for total strength and comprehensiveness. ICC scores for total implementation scores showed acceptable consistency among scorers. Cronbach's alpha values for all focus areas were acceptable. Strong content validity was measured through a committee vetting process. The development of this tool has far-reaching implications, bringing standardization of measurement to the field of land use plan assessment, and paving the way for systematic inclusion of health-related design principles, policies, and requirements in land use plans and their corresponding regulations. Copyright © 2016 Elsevier Inc. All rights reserved.

  1. The Theory of Planned Behavior (TPB) and Pre-Service Teachers' Technology Acceptance: A Validation Study Using Structural Equation Modeling

    ERIC Educational Resources Information Center

    Teo, Timothy; Tan, Lynde

    2012-01-01

    This study applies the theory of planned behavior (TPB), a theory that is commonly used in commercial settings, to the educational context to explain pre-service teachers' technology acceptance. It is also interested in examining its validity when used for this purpose. It has found evidence that the TPB is a valid model to explain pre-service…

  2. Development and construct validation of the Client-Centredness of Goal Setting (C-COGS) scale.

    PubMed

    Doig, Emmah; Prescott, Sarah; Fleming, Jennifer; Cornwell, Petrea; Kuipers, Pim

    2015-07-01

    Client-centred philosophy is integral to occupational therapy practice and client-centred goal planning is considered fundamental to rehabilitation. Evaluation of whether goal-planning practices are client-centred requires an understanding of the client's perspective about goal-planning processes and practices. The Client-Centredness of Goal Setting (C-COGS) was developed for use by practitioners who seek to be more client-centred and who require a scale to guide and evaluate individually orientated practice, especially with adults with cognitive impairment related to acquired brain injury. To describe development of the C-COGS scale and examine its construct validity. The C-COGS was administered to 42 participants with acquired brain injury after multidisciplinary goal planning. C-COGS scores were correlated with the Canadian Occupational Performance Measure (COPM) importance scores, and measures of therapeutic alliance, motivation, and global functioning to establish construct validity. The C-COGS scale has three subscales evaluating goal alignment, goal planning participation, and client-centredness of goals. The C-COGS subscale items demonstrated moderately significant correlations with scales measuring similar constructs. Findings provide preliminary evidence to support the construct validity of the C-COGS scale, which is intended to be used to evaluate and reflect on client-centred goal planning in clinical practice, and to highlight factors contributing to best practice rehabilitation.

  3. Development and Validation of a Gender Ideology Scale for Family Planning Services in Rural China

    PubMed Central

    Yang, Xueyan; Li, Shuzhuo; Feldman, Marcus W.

    2013-01-01

    The objectives of this study are to develop a scale of gender role ideology appropriate for assessing Quality of Care in family planning services for rural China. Literature review, focus-group discussions and in-depth interviews with service providers and clients from two counties in eastern and western China, as well as experts’ assessments, were used to develop a scale for family planning services. Psychometric methodologies were applied to samples of 601 service clients and 541 service providers from a survey in a district in central China to validate its internal consistency, reliability, and construct validity with realistic and strategic dimensions. This scale is found to be reliable and valid, and has prospects for application both academically and practically in the field. PMID:23573222

  4. Ocean Observations with EOS/MODIS: Algorithm Development and Post Launch Studies

    NASA Technical Reports Server (NTRS)

    Gordon, Howard R.; Conboy, Barbara (Technical Monitor)

    1999-01-01

    This separation has been logical thus far; however, as launch of AM-1 approaches, it must be recognized that many of these activities will shift emphasis from algorithm development to validation. For example, the second, third, and fifth bullets will become almost totally validation-focussed activities in the post-launch era, providing the core of our experimental validation effort. Work under the first bullet will continue into the post-launch time frame, driven in part by algorithm deficiencies revealed as a result of validation activities. Prior to the start of the 1999 fiscal year (FY99) we were requested to prepare a brief plan for our FY99 activities. This plan is included as Appendix 1. The present report describes the progress made on our planned activities.

  5. 16 CFR 310.4 - Abusive telemarketing acts or practices.

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... to a settlement agreement, debt management plan, or other such valid contractual agreement executed by the customer; (B) The customer has made at least one payment pursuant to that settlement agreement, debt management plan, or other valid contractual agreement between the customer and the creditor or...

  6. 16 CFR 310.4 - Abusive telemarketing acts or practices.

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... to a settlement agreement, debt management plan, or other such valid contractual agreement executed by the customer; (B) The customer has made at least one payment pursuant to that settlement agreement, debt management plan, or other valid contractual agreement between the customer and the creditor or...

  7. 16 CFR 310.4 - Abusive telemarketing acts or practices.

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... to a settlement agreement, debt management plan, or other such valid contractual agreement executed by the customer; (B) The customer has made at least one payment pursuant to that settlement agreement, debt management plan, or other valid contractual agreement between the customer and the creditor or...

  8. Applicability of action planning and coping planning to dental flossing among Norwegian adults: a confirmatory factor analysis approach.

    PubMed

    Astrøm, Anne Nordrehaug

    2008-06-01

    Using a prospective design and a representative sample of 25-yr-old Norwegians, this study hypothesized that action planning and coping planning will add to the prediction of flossing at 4 wk of follow-up over and above the effect of intention and previous flossing. This study tested the validity of a proposed 3-factor structure of the measurement model of intention, action planning, and coping planning and for its invariance across gender. A survey was conducted in three Norwegian counties, and 1,509 out of 8,000 randomly selected individuals completed questionnaires assessing the constructs of action planning and coping planning related to daily flossing. A random subsample of 500 participants was followed up at 4 wk with a telephone interview to assess flossing. Confirmatory factor analysis (CFA) confirmed the proposed 3-factor model after respecification. Although the chi-square test was statistically significant [chi(2) = 58.501, degrees of freedom (d.f.) = 17), complementary fit indices were satisfactory [goodness-of-fit index (GFI) = 0.99, root mean squared error of approximation (RMSEA) = 0.04]. Multigroup CFA provided evidence of complete invariance of the measurement model across gender. After controlling for previous flossing, intention (beta = 0.08) and action planning (beta = 0.11) emerged as independent predictors of subsequent flossing, accounting for 2.3% of its variance. Factorial validity of intention, action planning and coping planning, and the validity of action planning in predicting flossing prospectively, was confirmed by the present study.

  9. Highly Efficient Training, Refinement, and Validation of a Knowledge-based Planning Quality-Control System for Radiation Therapy Clinical Trials

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Li, Nan; Carmona, Ruben; Sirak, Igor

    Purpose: To demonstrate an efficient method for training and validation of a knowledge-based planning (KBP) system as a radiation therapy clinical trial plan quality-control system. Methods and Materials: We analyzed 86 patients with stage IB through IVA cervical cancer treated with intensity modulated radiation therapy at 2 institutions according to the standards of the INTERTECC (International Evaluation of Radiotherapy Technology Effectiveness in Cervical Cancer, National Clinical Trials Network identifier: 01554397) protocol. The protocol used a planning target volume and 2 primary organs at risk: pelvic bone marrow (PBM) and bowel. Secondary organs at risk were rectum and bladder. Initial unfiltered dose-volumemore » histogram (DVH) estimation models were trained using all 86 plans. Refined training sets were created by removing sub-optimal plans from the unfiltered sample, and DVH estimation models… and DVH estimation models were constructed by identifying 30 of 86 plans emphasizing PBM sparing (comparing protocol-specified dosimetric cutpoints V{sub 10} (percentage volume of PBM receiving at least 10 Gy dose) and V{sub 20} (percentage volume of PBM receiving at least 20 Gy dose) with unfiltered predictions) and another 30 of 86 plans emphasizing bowel sparing (comparing V{sub 40} (absolute volume of bowel receiving at least 40 Gy dose) and V{sub 45} (absolute volume of bowel receiving at least 45 Gy dose), 9 in common with the PBM set). To obtain deliverable KBP plans, refined models must inform patient-specific optimization objectives and/or priorities (an auto-planning “routine”). Four candidate routines emphasizing different tradeoffs were composed, and a script was developed to automatically re-plan multiple patients with each routine. After selection of the routine that best met protocol objectives in the 51-patient training sample (KBP{sub FINAL}), protocol-specific DVH metrics and normal tissue complication probability were compared for original versus KBP{sub FINAL} plans across the 35-patient validation set. Paired t tests were used to test differences between planning sets. Results: KBP{sub FINAL} plans outperformed manual planning across the validation set in all protocol-specific DVH cutpoints. The mean normal tissue complication probability for gastrointestinal toxicity was lower for KBP{sub FINAL} versus validation-set plans (48.7% vs 53.8%, P<.001). Similarly, the estimated mean white blood cell count nadir was higher (2.77 vs 2.49 k/mL, P<.001) with KBP{sub FINAL} plans, indicating lowered probability of hematologic toxicity. Conclusions: This work demonstrates that a KBP system can be efficiently trained and refined for use in radiation therapy clinical trials with minimal effort. This patient-specific plan quality control resulted in improvements on protocol-specific dosimetric endpoints.« less

  10. Institutional Effectiveness: A Model for Planning, Assessment & Validation.

    ERIC Educational Resources Information Center

    Truckee Meadows Community Coll., Sparks, NV.

    The report presents Truckee Meadows Community College's (Colorado) model for assessing institutional effectiveness and validating the College's mission and vision, and the strategic plan for carrying out the institutional effectiveness model. It also outlines strategic goals for the years 1999-2001. From the system-wide directive that education…

  11. Agent independent task planning

    NASA Technical Reports Server (NTRS)

    Davis, William S.

    1990-01-01

    Agent-Independent Planning is a technique that allows the construction of activity plans without regard to the agent that will perform them. Once generated, a plan is then validated and translated into instructions for a particular agent, whether a robot, crewmember, or software-based control system. Because Space Station Freedom (SSF) is planned for orbital operations for approximately thirty years, it will almost certainly experience numerous enhancements and upgrades, including upgrades in robotic manipulators. Agent-Independent Planning provides the capability to construct plans for SSF operations, independent of specific robotic systems, by combining techniques of object oriented modeling, nonlinear planning and temporal logic. Since a plan is validated using the physical and functional models of a particular agent, new robotic systems can be developed and integrated with existing operations in a robust manner. This technique also provides the capability to generate plans for crewmembers with varying skill levels, and later apply these same plans to more sophisticated robotic manipulators made available by evolutions in technology.

  12. Pretest information for a test to validate plume simulation procedures (FA-17)

    NASA Technical Reports Server (NTRS)

    Hair, L. M.

    1978-01-01

    The results of an effort to plan a final verification wind tunnel test to validate the recommended correlation parameters and application techniques were presented. The test planning effort was complete except for test site finalization and the associated coordination. Two suitable test sites were identified. Desired test conditions were shown. Subsequent sections of this report present the selected model and test site, instrumentation of this model, planned test operations, and some concluding remarks.

  13. The Role of Structural Models in the Solar Sail Flight Validation Process

    NASA Technical Reports Server (NTRS)

    Johnston, John D.

    2004-01-01

    NASA is currently soliciting proposals via the New Millennium Program ST-9 opportunity for a potential Solar Sail Flight Validation (SSFV) experiment to develop and operate in space a deployable solar sail that can be steered and provides measurable acceleration. The approach planned for this experiment is to test and validate models and processes for solar sail design, fabrication, deployment, and flight. These models and processes would then be used to design, fabricate, and operate scaleable solar sails for future space science missions. There are six validation objectives planned for the ST9 SSFV experiment: 1) Validate solar sail design tools and fabrication methods; 2) Validate controlled deployment; 3) Validate in space structural characteristics (focus of poster); 4) Validate solar sail attitude control; 5) Validate solar sail thrust performance; 6) Characterize the sail's electromagnetic interaction with the space environment. This poster presents a top-level assessment of the role of structural models in the validation process for in-space structural characteristics.

  14. SeaSat-A Satellite Scatterometer (SASS) Validation and Experiment Plan

    NASA Technical Reports Server (NTRS)

    Schroeder, L. C. (Editor)

    1978-01-01

    This plan was generated by the SeaSat-A satellite scatterometer experiment team to define the pre-and post-launch activities necessary to conduct sensor validation and geophysical evaluation. Details included are an instrument and experiment description/performance requirements, success criteria, constraints, mission requirements, data processing requirement and data analysis responsibilities.

  15. Validity of the Butcher Treatment Planning Inventory as a Measure of Negative Treatment Attitudes

    ERIC Educational Resources Information Center

    Hatchett, Gregory T.

    2007-01-01

    This study evaluated the validity of the Butcher Treatment Planning Inventory (BTPI) as a measure of negative expectations and attitudes toward counseling. Undergraduate students completed the BTPI, the Attitudes Toward Seeking Professional Psychological Help Scale-Abbreviated Version, and the Expectations About Counseling-Brief Form during one…

  16. Two-Method Planned Missing Designs for Longitudinal Research

    ERIC Educational Resources Information Center

    Garnier-Villarreal, Mauricio; Rhemtulla, Mijke; Little, Todd D.

    2014-01-01

    We examine longitudinal extensions of the two-method measurement design, which uses planned missingness to optimize cost-efficiency and validity of hard-to-measure constructs. These designs use a combination of two measures: a "gold standard" that is highly valid but expensive to administer, and an inexpensive (e.g., survey-based)…

  17. Targeting Low Career Confidence Using the Career Planning Confidence Scale

    ERIC Educational Resources Information Center

    McAuliffe, Garrett; Jurgens, Jill C.; Pickering, Worth; Calliotte, James; Macera, Anthony; Zerwas, Steven

    2006-01-01

    The authors describe the development and validation of a test of career planning confidence that makes possible the targeting of specific problem issues in employment counseling. The scale, developed using a rational process and the authors' experience with clients, was tested for criterion-related validity against 2 other measures. The scale…

  18. Using face validity to recognize empirical community observations.

    PubMed

    Gaber, John; Gaber, Sharon L

    2010-05-01

    There is a growing interest among international planning scholars to explore community participation in the plan making process from a qualitative research approach. In this paper the research assessment tool "face validity" is discussed as one way to help planners decipher when the community is sharing empirically grounded observations that can advance the applicability of the plan making process. Face validity provides a common sense assessment of research conclusions. It allows the assessor to look at an entire research project and ask: "on the face of things, does this research make sense?" With planners listening to citizen comments with an ear for face validity observations, holds open the opportunity for government to empirically learn from the community to see if they "got it right." And if not, to chart out a course on how they can get it right. Copyright 2009 Elsevier Ltd. All rights reserved.

  19. Draft Plan for Characterizing Commercial Data Products in Support of Earth Science Research

    NASA Technical Reports Server (NTRS)

    Ryan, Robert E.; Terrie, Greg; Berglund, Judith

    2006-01-01

    This presentation introduces a draft plan for characterizing commercial data products for Earth science research. The general approach to the commercial product verification and validation includes focused selection of a readily available commercial remote sensing products that support Earth science research. Ongoing product verification and characterization will question whether the product meets specifications and will examine its fundamental properties, potential and limitations. Validation will encourage product evaluation for specific science research and applications. Specific commercial products included in the characterization plan include high-spatial-resolution multispectral (HSMS) imagery and LIDAR data products. Future efforts in this process will include briefing NASA headquarters and modifying plans based on feedback, increased engagement with the science community and refinement of details, coordination with commercial vendors and The Joint Agency Commercial Imagery Evaluation (JACIE) for HSMS satellite acquisitions, acquiring waveform LIDAR data and performing verification and validation.

  20. A Comprehensive Plan for the Long-Term Calibration and Validation of Oceanic Biogeochemical Satellite Data

    NASA Technical Reports Server (NTRS)

    Hooker, Stanford B.; McClain, Charles R.; Mannino, Antonio

    2007-01-01

    The primary objective of this planning document is to establish a long-term capability and validating oceanic biogeochemical satellite data. It is a pragmatic solution to a practical problem based primarily o the lessons learned from prior satellite missions. All of the plan's elements are seen to be interdependent, so a horizontal organizational scheme is anticipated wherein the overall leadership comes from the NASA Ocean Biology and Biogeochemistry (OBB) Program Manager and the entire enterprise is split into two components of equal sature: calibration and validation plus satellite data processing. The detailed elements of the activity are based on the basic tasks of the two main components plus the current objectives of the Carbon Cycle and Ecosystems Roadmap. The former is distinguished by an internal core set of responsibilities and the latter is facilitated through an external connecting-core ring of competed or contracted activities. The core elements for the calibration and validation component include a) publish protocols and performance metrics; b) verify uncertainty budgets; c) manage the development and evaluation of instrumentation; and d) coordinate international partnerships. The core elements for the satellite data processing component are e) process and reprocess multisensor data; f) acquire, distribute, and archive data products; and g) implement new data products. Both components have shared responsibilities for initializing and temporally monitoring satellite calibration. Connecting-core elements include (but are not restricted to) atmospheric correction and characterization, standards and traceability, instrument and analysis round robins, field campaigns and vicarious calibration sites, in situ database, bio-optical algorithm (and product) validation, satellite characterization and vicarious calibration, and image processing software. The plan also includes an accountability process, creating a Calibration and Validation Team (to help manage the activity), and a discussion of issues associated with the plan's scientific focus.

  1. Factors Influencing the Career Planning and Development of University Students in Jordan

    ERIC Educational Resources Information Center

    Khasawneh, Samer

    2010-01-01

    The purpose of this study was to translate and validate an Arabic version of the career influence inventory for use in Jordan. The study also investigated perceptions of university students of the influential factors that have influenced their career planning and development. The validated career influence inventory was administered to 558…

  2. The Unified Language Testing Plan: Speaking Proficiency Test. Russian Pilot Validation Studies. Report Number 2.

    ERIC Educational Resources Information Center

    Thornton, Julie A.

    The report describes one segment of the Federal Language Testing Board's Unified Language Testing Plan (ULTP), the validation of the speaking proficiency test in Russian. The ULTP is a project to increase standardization of foreign language proficiency measurement and promote sharing of resources among testing programs in the federal government.…

  3. The Unified Language Testing Plan: Speaking Proficiency Test. Spanish and English Pilot Validation Studies. Report Number 1.

    ERIC Educational Resources Information Center

    Thornton, Julie A.

    This report describes one segment of the Federal Language Testing Board's Unified Language Testing Plan (ULTP), the validation of speaking proficiency tests in Spanish and English. The ULTP is a project to increase standardization of foreign language proficiency measurement and promote sharing of resources among testing programs in the federal…

  4. Using the Theory of Planned Behavior to Explain and Predict Behavior Intentions in Taiwan

    ERIC Educational Resources Information Center

    Wu, Cheng-Lung

    2015-01-01

    This study aims to use the theory of planned behavior to verify undergraduates' behavioral intentions regarding their participation in aquatic sports. Undergraduates in Taiwan serve as the research subjects and a survey method employs questionnaires. A total of 200 valid questionnaires were received out of 230, thus giving a valid response rate of…

  5. Streamlining Transportation Corridors Planning Processes and Validating the Application of Commercial Remote Sensing and Spatial Information (CRS-SI) Technologies for Environmental Impact Assessments

    DOT National Transportation Integrated Search

    2008-02-05

    The new US DOT RITA program has selected MSU for addressing corridor planning and environmental assessment in new and innovative ways that can be compared to traditional approaches. Our primary focus is on the application and validation of new and in...

  6. Validity and reliability analysis of the planned behavior theory scale related to the testicular self-examination in a Turkish context.

    PubMed

    Iyigun, Emine; Tastan, Sevinc; Ayhan, Hatice; Kose, Gulsah; Acikel, Cengizhan

    2016-06-01

    This study aimed to determine the validity and reliability levels of the Planned Behavior Theory Scale as related to a testicular self-examination. The study was carried out in a health-profession higher-education school in Ankara, Turkey, from April to June 2012. The study participants comprised 215 male students. Study data were collected by using a questionnaire, a planned behavior theory scale related to testicular self-examination, and Champion's Health Belief Model Scale (CHBMS). The sub-dimensions of the planned behavior theory scale, namely those of intention, attitude, subjective norms and self-efficacy, were found to have Cronbach's alpha values of between 0.81 and 0.89. Exploratory factor analysis showed that items of the scale had five factors that accounted for 75% of the variance. Of these, the sub-dimension of intention was found to have the highest level of contribution. A significant correlation was found between the sub-dimensions of the testicular self-examination planned behavior theory scale and those of CHBMS (p < 0.05). The findings suggest that the Turkish version of the testicular self-examination Planned Behavior Theory Scale is a valid and reliable measurement for Turkish society.

  7. Fixed-Precision Sequential Sampling Plans for Estimating Alfalfa Caterpillar, Colias lesbia, Egg Density in Alfalfa, Medicago sativa, Fields in Córdoba, Argentina

    PubMed Central

    Serra, Gerardo V.; Porta, Norma C. La; Avalos, Susana; Mazzuferi, Vilma

    2013-01-01

    The alfalfa caterpillar, Colias lesbia (Fabricius) (Lepidoptera: Pieridae), is a major pest of alfalfa, Medicago sativa L. (Fabales: Fabaceae), crops in Argentina. Its management is based mainly on chemical control of larvae whenever the larvae exceed the action threshold. To develop and validate fixed-precision sequential sampling plans, an intensive sampling programme for C. lesbia eggs was carried out in two alfalfa plots located in the Province of Córdoba, Argentina, from 1999 to 2002. Using Resampling for Validation of Sampling Plans software, 12 additional independent data sets were used to validate the sequential sampling plan with precision levels of 0.10 and 0.25 (SE/mean), respectively. For a range of mean densities of 0.10 to 8.35 eggs/sample, an average sample size of only 27 and 26 sample units was required to achieve a desired precision level of 0.25 for the sampling plans of Green and Kuno, respectively. As the precision level was increased to 0.10, average sample size increased to 161 and 157 sample units for the sampling plans of Green and Kuno, respectively. We recommend using Green's sequential sampling plan because it is less sensitive to changes in egg density. These sampling plans are a valuable tool for researchers to study population dynamics and to evaluate integrated pest management strategies. PMID:23909840

  8. Prototyping and validating requirements of radiation and nuclear emergency plan simulator

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Hamid, AHA., E-mail: amyhamijah@nm.gov.my; Faculty of Computing, Universiti Teknologi Malaysia; Rozan, MZA.

    2015-04-29

    Organizational incapability in developing unrealistic, impractical, inadequate and ambiguous mechanisms of radiological and nuclear emergency preparedness and response plan (EPR) causing emergency plan disorder and severe disasters. These situations resulting from 65.6% of poor definition and unidentified roles and duties of the disaster coordinator. Those unexpected conditions brought huge aftermath to the first responders, operators, workers, patients and community at large. Hence, in this report, we discuss prototyping and validating of Malaysia radiation and nuclear emergency preparedness and response plan simulation model (EPRM). A prototyping technique was required to formalize the simulation model requirements. Prototyping as systems requirements validation wasmore » carried on to endorse the correctness of the model itself against the stakeholder’s intensions in resolving those organizational incapability. We have made assumptions for the proposed emergency preparedness and response model (EPRM) through the simulation software. Those assumptions provided a twofold of expected mechanisms, planning and handling of the respective emergency plan as well as in bringing off the hazard involved. This model called RANEPF (Radiation and Nuclear Emergency Planning Framework) simulator demonstrated the training emergency response perquisites rather than the intervention principles alone. The demonstrations involved the determination of the casualties’ absorbed dose range screening and the coordination of the capacity planning of the expected trauma triage. Through user-centred design and sociotechnical approach, RANEPF simulator was strategized and simplified, though certainly it is equally complex.« less

  9. Prototyping and validating requirements of radiation and nuclear emergency plan simulator

    NASA Astrophysics Data System (ADS)

    Hamid, AHA.; Rozan, MZA.; Ibrahim, R.; Deris, S.; Selamat, A.

    2015-04-01

    Organizational incapability in developing unrealistic, impractical, inadequate and ambiguous mechanisms of radiological and nuclear emergency preparedness and response plan (EPR) causing emergency plan disorder and severe disasters. These situations resulting from 65.6% of poor definition and unidentified roles and duties of the disaster coordinator. Those unexpected conditions brought huge aftermath to the first responders, operators, workers, patients and community at large. Hence, in this report, we discuss prototyping and validating of Malaysia radiation and nuclear emergency preparedness and response plan simulation model (EPRM). A prototyping technique was required to formalize the simulation model requirements. Prototyping as systems requirements validation was carried on to endorse the correctness of the model itself against the stakeholder's intensions in resolving those organizational incapability. We have made assumptions for the proposed emergency preparedness and response model (EPRM) through the simulation software. Those assumptions provided a twofold of expected mechanisms, planning and handling of the respective emergency plan as well as in bringing off the hazard involved. This model called RANEPF (Radiation and Nuclear Emergency Planning Framework) simulator demonstrated the training emergency response perquisites rather than the intervention principles alone. The demonstrations involved the determination of the casualties' absorbed dose range screening and the coordination of the capacity planning of the expected trauma triage. Through user-centred design and sociotechnical approach, RANEPF simulator was strategized and simplified, though certainly it is equally complex.

  10. SU-E-T-129: Are Knowledge-Based Planning Dose Estimates Valid for Distensible Organs?

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Lalonde, R; Heron, D; Huq, M

    2015-06-15

    Purpose: Knowledge-based planning programs have become available to assist treatment planning in radiation therapy. Such programs can be used to generate estimated DVHs and planning constraints for organs at risk (OARs), based upon a model generated from previous plans. These estimates are based upon the planning CT scan. However, for distensible OARs like the bladder and rectum, daily variations in volume may make the dose estimates invalid. The purpose of this study is to determine whether knowledge-based DVH dose estimates may be valid for distensible OARs. Methods: The Varian RapidPlan™ knowledge-based planning module was used to generate OAR dose estimatesmore » and planning objectives for 10 prostate cases previously planned with VMAT, and final plans were calculated for each. Five weekly setup CBCT scans of each patient were then downloaded and contoured (assuming no change in size and shape of the target volume), and rectum and bladder DVHs were recalculated for each scan. Dose volumes were then compared at 75, 60,and 40 Gy for the bladder and rectum between the planning scan and the CBCTs. Results: Plan doses and estimates matched well at all dose points., Volumes of the rectum and bladder varied widely between planning CT and the CBCTs, ranging from 0.46 to 2.42 for the bladder and 0.71 to 2.18 for the rectum, causing relative dose volumes to vary between planning CT and CBCT, but absolute dose volumes were more consistent. The overall ratio of CBCT/plan dose volumes was 1.02 ±0.27 for rectum and 0.98 ±0.20 for bladder in these patients. Conclusion: Knowledge-based planning dose volume estimates for distensible OARs are still valid, in absolute volume terms, between treatment planning scans and CBCT’s taken during daily treatment. Further analysis of the data is being undertaken to determine how differences depend upon rectum and bladder filling state. This work has been supported by Varian Medical Systems.« less

  11. Assessing Assessment Texts: Where Is Planning?

    ERIC Educational Resources Information Center

    Fives, Helenrose; Barnes, Nicole; Dacey, Charity; Gillis, Anna

    2016-01-01

    We conducted a content analysis of 27 assessment textbooks to determine how assessment planning was framed in texts for preservice teachers. We identified eight assessment planning themes: alignment, assessment purpose and types, reliability and validity, writing goals and objectives, planning specific assessments, unpacking, overall assessment…

  12. Integration of oncologic margins in three-dimensional virtual planning for head and neck surgery, including a validation of the software pathway.

    PubMed

    Kraeima, Joep; Schepers, Rutger H; van Ooijen, Peter M A; Steenbakkers, Roel J H M; Roodenburg, Jan L N; Witjes, Max J H

    2015-10-01

    Three-dimensional (3D) virtual planning of reconstructive surgery, after resection, is a frequently used method for improving accuracy and predictability. However, when applied to malignant cases, the planning of the oncologic resection margins is difficult due to visualisation of tumours in the current 3D planning. Embedding tumour delineation on a magnetic resonance image, similar to the routinely performed radiotherapeutic contouring of tumours, is expected to provide better margin planning. A new software pathway was developed for embedding tumour delineation on magnetic resonance imaging (MRI) within the 3D virtual surgical planning. The software pathway was validated by the use of five bovine cadavers implanted with phantom tumour objects. MRI and computed tomography (CT) images were fused and the tumour was delineated using radiation oncology software. This data was converted to the 3D virtual planning software by means of a conversion algorithm. Tumour volumes and localization were determined in both software stages for comparison analysis. The approach was applied to three clinical cases. A conversion algorithm was developed to translate the tumour delineation data to the 3D virtual plan environment. The average difference in volume of the tumours was 1.7%. This study reports a validated software pathway, providing multi-modality image fusion for 3D virtual surgical planning. Copyright © 2015 European Association for Cranio-Maxillo-Facial Surgery. Published by Elsevier Ltd. All rights reserved.

  13. Validation Report for Joint Medical Planning Tool (JMPT) Version 7.5.6 Medical Planning Tool

    DTIC Science & Technology

    2013-09-19

    surgical 847.3 Sprain of sacrum Non-surgical 724.2 Lumbago Non-surgical 724.02 Spinal stenosis of lumbar region Non-surgical 681 Cellulitis and abscess... Cellulitis and abscess of face 682.6 Cellulitis and abscess of leg except foot 719.41 Pain in joint shoulder 11 JMPT Validation Report ICD-9 ICD-9

  14. Commissioning and validation of COMPASS system for VMAT patient specific quality assurance

    NASA Astrophysics Data System (ADS)

    Pimthong, J.; Kakanaporn, C.; Tuntipumiamorn, L.; Laojunun, P.; Iampongpaiboon, P.

    2016-03-01

    Pre-treatment patient specific quality assurance (QA) of advanced treatment techniques such as volumetric modulated arc therapy (VMAT) is one of important QA in radiotherapy. The fast and reliable dosimetric device is required. The objective of this study is to commission and validate the performance of COMPASS system for dose verification of VMAT technique. The COMPASS system is composed of an array of ionization detectors (MatriXX) mounted to the gantry using a custom holder and software for the analysis and visualization of QA results. We validated the COMPASS software for basic and advanced clinical application. For the basic clinical study, the simple open field in various field sizes were validated in homogeneous phantom. And the advanced clinical application, the fifteen prostate and fifteen nasopharyngeal cancers VMAT plans were chosen to study. The treatment plans were measured by the MatriXX. The doses and dose-volume histograms (DVHs) reconstructed from the fluence measurements were compared to the TPS calculated plans. And also, the doses and DVHs computed using collapsed cone convolution (CCC) Algorithm were compared with Eclipse TPS calculated plans using Analytical Anisotropic Algorithm (AAA) that according to dose specified in ICRU 83 for PTV.

  15. Development and Validation of an Algorithm to Identify Planned Readmissions From Claims Data.

    PubMed

    Horwitz, Leora I; Grady, Jacqueline N; Cohen, Dorothy B; Lin, Zhenqiu; Volpe, Mark; Ngo, Chi K; Masica, Andrew L; Long, Theodore; Wang, Jessica; Keenan, Megan; Montague, Julia; Suter, Lisa G; Ross, Joseph S; Drye, Elizabeth E; Krumholz, Harlan M; Bernheim, Susannah M

    2015-10-01

    It is desirable not to include planned readmissions in readmission measures because they represent deliberate, scheduled care. To develop an algorithm to identify planned readmissions, describe its performance characteristics, and identify improvements. Consensus-driven algorithm development and chart review validation study at 7 acute-care hospitals in 2 health systems. For development, all discharges qualifying for the publicly reported hospital-wide readmission measure. For validation, all qualifying same-hospital readmissions that were characterized by the algorithm as planned, and a random sampling of same-hospital readmissions that were characterized as unplanned. We calculated weighted sensitivity and specificity, and positive and negative predictive values of the algorithm (version 2.1), compared to gold standard chart review. In consultation with 27 experts, we developed an algorithm that characterizes 7.8% of readmissions as planned. For validation we reviewed 634 readmissions. The weighted sensitivity of the algorithm was 45.1% overall, 50.9% in large teaching centers and 40.2% in smaller community hospitals. The weighted specificity was 95.9%, positive predictive value was 51.6%, and negative predictive value was 94.7%. We identified 4 minor changes to improve algorithm performance. The revised algorithm had a weighted sensitivity 49.8% (57.1% at large hospitals), weighted specificity 96.5%, positive predictive value 58.7%, and negative predictive value 94.5%. Positive predictive value was poor for the 2 most common potentially planned procedures: diagnostic cardiac catheterization (25%) and procedures involving cardiac devices (33%). An administrative claims-based algorithm to identify planned readmissions is feasible and can facilitate public reporting of primarily unplanned readmissions. © 2015 Society of Hospital Medicine.

  16. Mars Exploration Rover Mission: Entry, Descent, and Landing System Validation

    NASA Technical Reports Server (NTRS)

    Mitcheltree, Robert A.; Lee, Wayne; Steltzner, Adam; SanMartin, Alejanhdro

    2004-01-01

    System validation for a Mars entry, descent, and landing system is not simply a demonstration that the electrical system functions in the associated environments. The function of this system is its interaction with the atmospheric and surface environment. Thus, in addition to traditional test-bed, hardware-in-the-loop, testing, a validation program that confirms the environmental interaction is required. Unfortunately, it is not possible to conduct a meaningful end-to-end test of a Mars landing system on Earth. The validation plan must be constructed from an interconnected combination of simulation, analysis and test. For the Mars Exploration Rover mission, this combination of activities and the logic of how they combined to the system's validation was explicitly stated, reviewed, and tracked as part of the development plan.

  17. Psychometric Testing of the Self-Efficacy for Interdisciplinary Plans of Care Scale.

    PubMed

    Molle, Elizabeth; Froman, Robin

    2017-01-01

    Computerized interdisciplinary plans of care have revitalized nurse-centric care plans into dynamic and meaningful electronic documents. To maximize the benefits of these documents, it is important to understand healthcare professionals' attitudes, specifically their confidence, for making computerized interdisciplinary care plans useful and meaningful documents. The purpose of the study was to test the psychometric properties of the Self-Efficacy for Interdisciplinary Plans of Care instrument intended to measure healthcare professionals' self-efficacy for using such documents. Content validity was assessed by an expert review panel. Content validity indices ranged from 0.75 to 1.00, with a scale CVI of 0.94. A sample of 389 healthcare providers completed the 14-item instrument. Principal axis factoring was used to assess factor structure. The exploratory factor analysis yielded a single-factor structure accounting for 71.76% of covariance. Cronbach internal consistency coefficient for the single factor solution was .97. The corrected item-total correlations ranged from 0.71 to 0.90. The coefficient of stability, during a 2-week period, with a subset of the sample (n = 38), was estimated at 0.82. The results of this study suggest that the Self-Efficacy for Interdisciplinary Plans of Care has sturdy reliability and validity for measuring the self-efficacy of healthcare providers to make computerized interdisciplinary plans of care meaningful and useful documents.

  18. Requirements and feasibility study of flight demonstration of Active Controls Technology (ACT) on the NASA 515 airplane

    NASA Technical Reports Server (NTRS)

    Gordon, C. K.

    1975-01-01

    A preliminary design study was conducted to evaluate the suitability of the NASA 515 airplane as a flight demonstration vehicle, and to develop plans, schedules, and budget costs for fly-by-wire/active controls technology flight validation in the NASA 515 airplane. The preliminary design and planning were accomplished for two phases of flight validation.

  19. Using Structural Equation Modeling to Validate the Theory of Planned Behavior as a Model for Predicting Student Cheating

    ERIC Educational Resources Information Center

    Mayhew, Matthew J.; Hubbard, Steven M.; Finelli, Cynthia J.; Harding, Trevor S.; Carpenter, Donald D.

    2009-01-01

    The purpose of this paper is to validate the use of a modified Theory of Planned Behavior (TPB) for predicting undergraduate student cheating. Specifically, we administered a survey assessing how the TPB relates to cheating along with a measure of moral reasoning (DIT- 2) to 527 undergraduate students across three institutions; and analyzed the…

  20. Validation of Mission Plans Through Simulation

    NASA Astrophysics Data System (ADS)

    St-Pierre, J.; Melanson, P.; Brunet, C.; Crabtree, D.

    2002-01-01

    The purpose of a spacecraft mission planning system is to automatically generate safe and optimized mission plans for a single spacecraft, or more functioning in unison. The system verifies user input syntax, conformance to commanding constraints, absence of duty cycle violations, timing conflicts, state conflicts, etc. Present day constraint-based systems with state-based predictive models use verification rules derived from expert knowledge. A familiar solution found in Mission Operations Centers, is to complement the planning system with a high fidelity spacecraft simulator. Often a dedicated workstation, the simulator is frequently used for operator training and procedure validation, and may be interfaced to actual control stations with command and telemetry links. While there are distinct advantages to having a planning system offer realistic operator training using the actual flight control console, physical verification of data transfer across layers and procedure validation, experience has revealed some drawbacks and inefficiencies in ground segment operations: With these considerations, two simulation-based mission plan validation projects are under way at the Canadian Space Agency (CSA): RVMP and ViSION. The tools proposed in these projects will automatically run scenarios and provide execution reports to operations planning personnel, prior to actual command upload. This can provide an important safeguard for system or human errors that can only be detected with high fidelity, interdependent spacecraft models running concurrently. The core element common to these projects is a spacecraft simulator, built with off-the- shelf components such as CAE's Real-Time Object-Based Simulation Environment (ROSE) technology, MathWork's MATLAB/Simulink, and Analytical Graphics' Satellite Tool Kit (STK). To complement these tools, additional components were developed, such as an emulated Spacecraft Test and Operations Language (STOL) interpreter and CCSDS TM/TC encoders and decoders. This paper discusses the use of simulation in the context of space mission planning, describes the projects under way and proposes additional venues of investigation and development.

  1. Development and Validation of a Questionnaire to Detect Behavior Change in Multiple Advance Care Planning Behaviors

    PubMed Central

    Sudore, Rebecca L.; Stewart, Anita L.; Knight, Sara J.; McMahan, Ryan D.; Feuz, Mariko; Miao, Yinghui; Barnes, Deborah E.

    2013-01-01

    Introduction Advance directives have traditionally been considered the gold standard for advance care planning. However, recent evidence suggests that advance care planning involves a series of multiple discrete behaviors for which people are in varying stages of behavior change. The goal of our study was to develop and validate a survey to measure the full advance care planning process. Methods The Advance Care Planning Engagement Survey assesses “Process Measures” of factors known from Behavior Change Theory to affect behavior (knowledge, contemplation, self-efficacy, and readiness, using 5-point Likert scales) and “Action Measures” (yes/no) of multiple behaviors related to surrogate decision makers, values and quality of life, flexibility for surrogate decision making, and informed decision making. We administered surveys at baseline and 1 week later to 50 diverse, older adults from San Francisco hospitals. Internal consistency reliability of Process Measures was assessed using Cronbach's alpha (only continuous variables) and test-retest reliability of Process and Action Measures was examined using intraclass correlations. For discriminant validity, we compared Process and Action Measure scores between this cohort and 20 healthy college students (mean age 23.2 years, SD 2.7). Results Mean age was 69.3 (SD 10.5) and 42% were non-White. The survey took a mean of 21.4 minutes (±6.2) to administer. The survey had good internal consistency (Process Measures Cronbach's alpha, 0.94) and test-retest reliability (Process Measures intraclass correlation, 0.70; Action Measures, 0.87). Both Process and Action Measure scores were higher in the older than younger group, p<.001. Conclusion A new Advance Care Planning Engagement Survey that measures behavior change (knowledge, contemplation, self-efficacy, and readiness) and multiple advance care planning actions demonstrates good reliability and validity. Further research is needed to assess whether survey scores improve in response to advance care planning interventions and whether scores are associated with receipt of care consistent with one's wishes. PMID:24039772

  2. Marketing Plan for Demonstration and Validation Assets

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    None, None

    The National Security Preparedness Project (NSPP), is to be sustained by various programs, including technology demonstration and evaluation (DEMVAL). This project assists companies in developing technologies under the National Security Technology Incubator program (NSTI) through demonstration and validation of technologies applicable to national security created by incubators and other sources. The NSPP also will support the creation of an integrated demonstration and validation environment. This report documents the DEMVAL marketing and visibility plan, which will focus on collecting information about, and expanding the visibility of, DEMVAL assets serving businesses with national security technology applications in southern New Mexico.

  3. Computerized Planning of Cryosurgery Using Bubble Packing: An Experimental Validation on a Phantom Material

    PubMed Central

    Rossi, Michael R.; Tanaka, Daigo; Shimada, Kenji; Rabin, Yoed

    2009-01-01

    The current study focuses on experimentally validating a planning scheme based on the so-called bubble-packing method. This study is a part of an ongoing effort to develop computerized planning tools for cryosurgery, where bubble packing has been previously developed as a means to find an initial, uniform distribution of cryoprobes within a given domain; the so-called force-field analogy was then used to move cryoprobes to their optimum layout. However, due to the high quality of the cryoprobes’ distribution, suggested by bubble packing and its low computational cost, it has been argued that a planning scheme based solely on bubble packing may be more clinically relevant. To test this argument, an experimental validation is performed on a simulated cross-section of the prostate, using gelatin solution as a phantom material, proprietary liquid-nitrogen based cryoprobes, and a cryoheater to simulate urethral warming. Experimental results are compared with numerically simulated temperature histories resulting from planning. Results indicate an average disagreement of 0.8 mm in identifying the freezing front location, which is an acceptable level of uncertainty in the context of prostate cryosurgery imaging. PMID:19885373

  4. 42 CFR 423.514 - Validation of Part D reporting requirements.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 42 Public Health 3 2011-10-01 2011-10-01 false Validation of Part D reporting requirements. 423... Procedures and Contracts with Part D plan sponsors § 423.514 Validation of Part D reporting requirements. (a... request. (g) Data validation. Each Part D sponsor must subject information collected under paragraph (a...

  5. Global Precipitation Measurement (GPM) Ground Validation: Plans and Preparations

    NASA Technical Reports Server (NTRS)

    Schwaller, M.; Bidwell, S.; Durning, F. J.; Smith, E.

    2004-01-01

    The Global Precipitation Measurement (GPM) program is an international partnership led by the National Aeronautics and Space Administration (NASA) and the Japan Aerospace Exploration Agency (JAXA). GPM will improve climate, weather, and hydro-meteorological forecasts through more frequent and more accurate measurement of precipitation across the globe. This paper describes the concept, the planning, and the preparations for Ground Validation within the GPM program. Ground Validation (GV) plays an important role in the program by investigating and quantitatively assessing the errors within the satellite retrievals. These quantitative estimates of retrieval errors will assist the scientific community by bounding the errors within their research products. The two fundamental requirements of the GPM Ground Validation program are: (1) error characterization of the precipitation retrievals and (2) continual improvement of the satellite retrieval algorithms. These two driving requirements determine the measurements, instrumentation, and location for ground observations. This paper outlines GV plans for estimating the systematic and random components of retrieval error and for characterizing the spatial p d temporal structure of the error and plans for algorithm improvement in which error models are developed and experimentally explored to uncover the physical causes of errors within the retrievals. This paper discusses NASA locations for GV measurements as well as anticipated locations from international GPM partners. NASA's primary locations for validation measurements are an oceanic site at Kwajalein Atoll in the Republic of the Marshall Islands and a continental site in north-central Oklahoma at the U.S. Department of Energy's Atmospheric Radiation Measurement Program site.

  6. 26 CFR 1.401-12 - Requirements for qualification of trusts and plans benefiting owner-employees.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... plan and may not be amended except for a valid business reason. (3) The requirement that a profit... “wages” under section 3121(a)(1). (4) A money purchase pension plan or a profit-sharing plan may provide... property, other than money, made after December 31, 1974. (l) Controlled trades or businesses—(1) Plans...

  7. 26 CFR 1.401-12 - Requirements for qualification of trusts and plans benefiting owner-employees.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... plan and may not be amended except for a valid business reason. (3) The requirement that a profit... “wages” under section 3121(a)(1). (4) A money purchase pension plan or a profit-sharing plan may provide... property, other than money, made after December 31, 1974. (l) Controlled trades or businesses—(1) Plans...

  8. 26 CFR 1.401-12 - Requirements for qualification of trusts and plans benefiting owner-employees.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... plan and may not be amended except for a valid business reason. (3) The requirement that a profit... “wages” under section 3121(a)(1). (4) A money purchase pension plan or a profit-sharing plan may provide... property, other than money, made after December 31, 1974. (l) Controlled trades or businesses—(1) Plans...

  9. 26 CFR 1.401-12 - Requirements for qualification of trusts and plans benefiting owner-employees.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... plan and may not be amended except for a valid business reason. (3) The requirement that a profit... “wages” under section 3121(a)(1). (4) A money purchase pension plan or a profit-sharing plan may provide... property, other than money, made after December 31, 1974. (l) Controlled trades or businesses—(1) Plans...

  10. 26 CFR 1.401-12 - Requirements for qualification of trusts and plans benefiting owner-employees.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... plan and may not be amended except for a valid business reason. (3) The requirement that a profit... “wages” under section 3121(a)(1). (4) A money purchase pension plan or a profit-sharing plan may provide... property, other than money, made after December 31, 1974. (l) Controlled trades or businesses—(1) Plans...

  11. Development of an Updated Strategic Marketing Plan for Fox Valley Technical College.

    ERIC Educational Resources Information Center

    May, Susan A.

    This project was conducted to develop a comprehensive strategic marketing plan for Fox Valley Technical College (FVTC). Components included a review of the literature, establishing criteria for the plan, validation of the criteria, the actual development of the plan involving a formative committee, and the review of institutional marketing plans…

  12. 48 CFR 1852.234-2 - Earned Value Management System.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... compliance/validation. The Contractor shall follow and implement the approved compliance/validation plan in a... process. (f) The Contractor shall be responsible for ensuring that its subcontractors, identified below... compliance/validation. (Contracting Officer to insert names of subcontractors or subcontracted effort.) (g...

  13. 48 CFR 1852.234-2 - Earned Value Management System.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... compliance/validation. The Contractor shall follow and implement the approved compliance/validation plan in a... process. (f) The Contractor shall be responsible for ensuring that its subcontractors, identified below... compliance/validation. (Contracting Officer to insert names of subcontractors or subcontracted effort.) (g...

  14. 48 CFR 1852.234-2 - Earned Value Management System.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... compliance/validation. The Contractor shall follow and implement the approved compliance/validation plan in a... process. (f) The Contractor shall be responsible for ensuring that its subcontractors, identified below... compliance/validation. (Contracting Officer to insert names of subcontractors or subcontracted effort.) (g...

  15. Design and validation of pictograms in a pediatric anaphylaxis action plan.

    PubMed

    Mok, Garrick; Vaillancourt, Régis; Irwin, Danica; Wong, Alexandre; Zemek, Roger; Alqurashi, Waleed

    2015-05-01

    Current anaphylaxis action plans (AAPs) are based on written instructions without inclusion of pictograms. To develop an AAP with pictorial aids and to prospectively validate the pictogram components of this plan. Participants recruited from the emergency department and allergy clinic participated in a questionnaire to validate pictograms depicting key counseling points of an anaphylactic reaction. Children ≥ 10 years of age and caregivers of children < 10 years with acute anaphylaxis or who carried epinephrine auto-injector for confirmed allergy were eligible. Guessability, translucency, and recall were assessed for 11 pictogram designs. Pictograms identified as correct or partially correct by at least 85% of participants were considered valid. Three independent reviewers assessed these outcome measures. Of the 115 total participants, 73 (63%) were female, 76 (66%) were parents/guardians, and 39 (34%) were children aged 10-17. Overall, 10 pictograms (91%) reached ≥ 85% for correct guessability, translucency, and recall. Four pictograms were redesigned to reach the preset validation target. One pictogram depicting symptom management (5-min wait time after first epinephrine treatment) reached 82% translucency after redesign. However, it reached 98% and 100% of correct guessability and recall, respectively. We prospectively designed and validated a set of pictograms to be included in an AAP. The incorporation of validated pictograms into an AAP may potentially increase comprehension of the triggers, signs and symptoms, and management of an anaphylactic reaction. © 2015 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  16. Measuring the impact of diagnostic decision support on the quality of clinical decision making: development of a reliable and valid composite score.

    PubMed

    Ramnarayan, Padmanabhan; Kapoor, Ritika R; Coren, Michael; Nanduri, Vasantha; Tomlinson, Amanda L; Taylor, Paul M; Wyatt, Jeremy C; Britto, Joseph F

    2003-01-01

    Few previous studies evaluating the benefits of diagnostic decision support systems have simultaneously measured changes in diagnostic quality and clinical management prompted by use of the system. This report describes a reliable and valid scoring technique to measure the quality of clinical decision plans in an acute medical setting, where diagnostic decision support tools might prove most useful. Sets of differential diagnoses and clinical management plans generated by 71 clinicians for six simulated cases, before and after decision support from a Web-based pediatric differential diagnostic tool (ISABEL), were used. A composite quality score was calculated separately for each diagnostic and management plan by considering the appropriateness value of each component diagnostic or management suggestion, a weighted sum of individual suggestion ratings, relevance of the entire plan, and its comprehensiveness. The reliability and validity (face, concurrent, construct, and content) of these two final scores were examined. Two hundred fifty-two diagnostic and 350 management suggestions were included in the interrater reliability analysis. There was good agreement between raters (intraclass correlation coefficient, 0.79 for diagnoses, and 0.72 for management). No counterintuitive scores were demonstrated on visual inspection of the sets. Content validity was verified by a consultation process with pediatricians. Both scores discriminated adequately between the plans of consultants and medical students and correlated well with clinicians' subjective opinions of overall plan quality (Spearman rho 0.65, p < 0.01). The diagnostic and management scores for each episode showed moderate correlation (r = 0.51). The scores described can be used as key outcome measures in a larger study to fully assess the value of diagnostic decision aids, such as the ISABEL system.

  17. Validation of Aura Data: Needs and Implementation

    NASA Astrophysics Data System (ADS)

    Froidevaux, L.; Douglass, A. R.; Schoeberl, M. R.; Hilsenrath, E.; Kinnison, D. E.; Kroon, M.; Sander, S. P.

    2003-12-01

    Validation of Aura data: needs and implementation L. Froidevaux, A. R. Douglass, M. R. Schoeberl, E. Hilsenrath, D. Kinnison, M. Kroon, and S. P. Sander We describe the needs for validation of the Aura scientific data products expected in 2004 and for several years thereafter, as well as the implementation plan to fullfill these needs. Many profiles of stratospheric and tropospheric composition are expected from the combination of four instruments aboard Aura, along with column abundances, aerosol and cloud information. The Aura validation working group and the Aura Project have been developing programs and collaborations that are expected to lead to a significant number of validation activities after the Aura launch (in early 2004). Spatial and temporal variability in the lower stratosphere and troposphere present challenges to validation of Aura measurements even where cloud contamination effects can be minimized. Data from ground-based networks, balloons, and other satellites will contribute in a major way to Aura data validation. In addition, plans are in place to obtain correlative data for special conditions, such as profiles of O3 and NO2 in polluted areas. Several aircraft campaigns planned for the 2004-2007 time period will provide additional tropospheric and lower stratospheric validation opportunities for Aura; some atmospheric science goals will be addressed by the eventual combination of these data sets. A team of "Aura liaisons" will assist in the dissemination of information about various correlative measurements to be expected in the above timeframe, along with any needed protocols and agreements on data exchange and file formats. A data center is being established at the Goddard Space Flight Center to collect and distribute the various data files to be used in the validation of the Aura data.

  18. SU-E-J-244: Development and Validation of a Knowledge Based Planning Model for External Beam Radiation Therapy of Locally Advanced Non-Small Cell Lung Cancer

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Liu, Z; Kennedy, A; Larsen, E

    2015-06-15

    Purpose: The study aims to develop and validate a knowledge based planning (KBP) model for external beam radiation therapy of locally advanced non-small cell lung cancer (LA-NSCLC). Methods: RapidPlan™ technology was used to develop a lung KBP model. Plans from 65 patients with LA-NSCLC were used to train the model. 25 patients were treated with VMAT, and the other patients were treated with IMRT. Organs-at-risk (OARs) included right lung, left lung, heart, esophagus, and spinal cord. DVH and geometric distribution DVH were extracted from the treated plans. The model was trained using principal component analysis and step-wise multiple regression. Boxmore » plot and regression plot tools were used to identify geometric outliers and dosimetry outliers and help fine-tune the model. The validation was performed by (a) comparing predicted DVH boundaries to actual DVHs of 63 patients and (b) using an independent set of treatment planning data. Results: 63 out of 65 plans were included in the final KBP model with PTV volume ranging from 102.5cc to 1450.2cc. Total treatment dose prescription varied from 50Gy to 70Gy based on institutional guidelines. One patient was excluded due to geometric outlier where 2.18cc of spinal cord was included in PTV. The other patient was excluded due to dosimetric outlier where the dose sparing to spinal cord was heavily enforced in the clinical plan. Target volume, OAR volume, OAR overlap volume percentage to target, and OAR out-of-field volume were included in the trained model. Lungs and heart had two principal component scores of GEDVH, whereas spinal cord and esophagus had three in the final model. Predicted DVH band (mean ±1 standard deviation) represented 66.2±3.6% of all DVHs. Conclusion: A KBP model was developed and validated for radiotherapy of LA-NSCLC in a commercial treatment planning system. The clinical implementation may improve the consistency of IMRT/VMAT planning.« less

  19. SU-D-BRD-06: Automated Population-Based Planning for Whole Brain Radiation Therapy

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Schreibmann, E; Fox, T; Crocker, I

    2014-06-01

    Purpose: Treatment planning for whole brain radiation treatment is technically a simple process but in practice it takes valuable clinical time of repetitive and tedious tasks. This report presents a method that automatically segments the relevant target and normal tissues and creates a treatment plan in only a few minutes after patient simulation. Methods: Segmentation is performed automatically through morphological operations on the soft tissue. The treatment plan is generated by searching a database of previous cases for patients with similar anatomy. In this search, each database case is ranked in terms of similarity using a customized metric designed formore » sensitivity by including only geometrical changes that affect the dose distribution. The database case with the best match is automatically modified to replace relevant patient info and isocenter position while maintaining original beam and MLC settings. Results: Fifteen patients were used to validate the method. In each of these cases the anatomy was accurately segmented to mean Dice coefficients of 0.970 ± 0.008 for the brain, 0.846 ± 0.009 for the eyes and 0.672 ± 0.111 for the lens as compared to clinical segmentations. Each case was then subsequently matched against a database of 70 validated treatment plans and the best matching plan (termed auto-planned), was compared retrospectively with the clinical plans in terms of brain coverage and maximum doses to critical structures. Maximum doses were reduced by a maximum of 20.809 Gy for the left eye (mean 3.533), by 13.352 (1.311) for the right eye, and by 27.471 (4.856), 25.218 (6.315) for the left and right lens. Time from simulation to auto-plan was 3-4 minutes. Conclusion: Automated database- based matching is an alternative to classical treatment planning that improves quality while providing a cost—effective solution to planning through modifying previous validated plans to match a current patient's anatomy.« less

  20. 7 CFR 25.404 - Validation of designation.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... maintain a process for ensuring ongoing broad-based participation by community residents consistent with the approved application and planning process outlined in the strategic plan. (1) Continuous... benchmarks, the process it will use for reviewing goals and benchmarks and revising its strategic plan. (2...

  1. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Wang, J; Hu, W; Chen, X

    Purpose: The aim of this study is to investigate the feasibility of using RapidPlan for breast cancer radiotherapy and to evaluate its performance for planners with different planning experiences. Methods: A training database was collected with 80 expert plan datasets from patients previously received left breast conserving surgery and IMRT-simultaneously integrated boost radiotherapy. The models were created on the RapidPlan. Five patients from the training database and 5 external patients were used for internal and external validation, respectively. Three planners with different planning experiences (beginner, junior, senior) designed manual and RapidPlan based plans for additional ten patients. The plan qualitiesmore » were compared with manual and RapidPlan based ones. Results: For the internal and external validations, there were no significant dose differences on target coverage for plans from RapidPlan and manual. Also, no difference was found in the mean doses to contralateral breast and lung. The RapidPlan improved the heart (V5, V10, V20, V30, and mead dose) and ipsilateral lung (V5, V10, V20, V30, and mean dose) sparing for the beginner and junior planners. Compare to the plans from senior planner, 6 out of 16 clinically checked parameters were improved in RapidPlan, and the left parameters were similar. Conclusion: It is feasible to generate clinical acceptable plans using RapidPlan for breast cancer radiotherapy. The RapidPlan helps to systematically improve the quality of IMRT plans against the benchmark of clinically accepted plans. The RapidPlan shows promise for homogenizing plan quality by transferring planning expertise from more experienced to less experienced planners.« less

  2. Contributions of the SDR Task Network tool to Calibration and Validation of the NPOESS Preparatory Project instruments

    NASA Astrophysics Data System (ADS)

    Feeley, J.; Zajic, J.; Metcalf, A.; Baucom, T.

    2009-12-01

    The National Polar-orbiting Operational Environmental Satellite System (NPOESS) Preparatory Project (NPP) Calibration and Validation (Cal/Val) team is planning post-launch activities to calibrate the NPP sensors and validate Sensor Data Records (SDRs). The IPO has developed a web-based data collection and visualization tool in order to effectively collect, coordinate, and manage the calibration and validation tasks for the OMPS, ATMS, CrIS, and VIIRS instruments. This tool is accessible to the multi-institutional Cal/Val teams consisting of the Prime Contractor and Government Cal/Val leads along with the NASA NPP Mission team, and is used for mission planning and identification/resolution of conflicts between sensor activities. Visualization techniques aid in displaying task dependencies, including prerequisites and exit criteria, allowing for the identification of a critical path. This presentation will highlight how the information is collected, displayed, and used to coordinate the diverse instrument calibration/validation teams.

  3. Soldier Dimensions in Combat Models

    DTIC Science & Technology

    1990-05-07

    and performance. Questionnaires, SQTs, and ARTEPs were often used. Many scales had estimates of reliability but few had validity data. Most studies...pending its validation . Research plans were provided for applications in simulated combat and with simulation devices, for data previously gathered...regarding reliability and validity . Lack of information following an instrument indicates neither reliability nor validity information was provided by the

  4. Planning of reach-and-grasp movements: effects of validity and type of object information

    NASA Technical Reports Server (NTRS)

    Loukopoulos, L. D.; Engelbrecht, S. F.; Berthier, N. E.

    2001-01-01

    Individuals are assumed to plan reach-and-grasp movements by using two separate processes. In 1 of the processes, extrinsic (direction, distance) object information is used in planning the movement of the arm that transports the hand to the target location (transport planning); whereas in the other, intrinsic (shape) object information is used in planning the preshaping of the hand and the grasping of the target object (manipulation planning). In 2 experiments, the authors used primes to provide information to participants (N = 5, Experiment 1; N = 6, Experiment 2) about extrinsic and intrinsic object properties. The validity of the prime information was systematically varied. The primes were succeeded by a cue, which always correctly identified the location and shape of the target object. Reaction times were recorded. Four models of transport and manipulation planning were tested. The only model that was consistent with the data was 1 in which arm transport and object manipulation planning were postulated to be independent processes that operate partially in parallel. The authors suggest that the processes involved in motor planning before execution are primarily concerned with the geometric aspects of the upcoming movement but not with the temporal details of its execution.

  5. Soil Moisture Active Passive (SMAP) Calibration and Validation Plan and Current Activities

    NASA Technical Reports Server (NTRS)

    Jackson, T. J.; Cosh, M.; Bindlish, R.; Crow, W.; Colliander, A.; Njoku, E.; McDonald, K.; Kimball, J.; Belair, S.; Walker, J.; hide

    2010-01-01

    The primary objective of the SMAP calibration and validation (Cal/Val) program is demonstrating that the science requirements (product accuracy and bias) have been met over the mission life. This begins during pre-launch with activities that contribute to high quality products and establishing post-launch validation infrastructure and continues through the mission life. However, the major focus is on a relatively short Cal/Val period following launch. The general approach and elements of the SMAP Cal/Val plan will be described and along with details on several ongoing or recent field experiments designed to address both near- and long-term Cal/Val.

  6. 76 FR 40753 - NASA Advisory Council; Aeronautics Committee; Meeting

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-07-11

    ... strategy Verification and Validation of Flight Critical Systems planning update NASA Aeronautics systems analysis and strategic planning It is imperative that this meeting be held on this date to accommodate the... aeronautics community and other persons, research and technical information relevant to program planning...

  7. Validating the Electric Maze Task as a Measure of Planning

    ERIC Educational Resources Information Center

    Sheppard, Kelly W.; Cheatham, Carol L.

    2017-01-01

    The Electric Maze Task (EMT) is a novel planning task designed to allow flexible testing of planning abilities across a broad age range and to incorporate manipulations to test underlying planning abilities, such as working-memory and inhibitory control skills. The EMT was tested in a group of 63 typically developing 7- to 12-year-olds.…

  8. Commissioning of intensity modulated neutron radiotherapy (IMNRT).

    PubMed

    Burmeister, Jay; Spink, Robyn; Liang, Liang; Bossenberger, Todd; Halford, Robert; Brandon, John; Delauter, Jonathan; Snyder, Michael

    2013-02-01

    Intensity modulated neutron radiotherapy (IMNRT) has been developed using inhouse treatment planning and delivery systems at the Karmanos Cancer Center∕Wayne State University Fast Neutron Therapy facility. The process of commissioning IMNRT for clinical use is presented here. Results of commissioning tests are provided including validation measurements using representative patient plans as well as those from the TG-119 test suite. IMNRT plans were created using the Varian Eclipse optimization algorithm and an inhouse planning system for calculation of neutron dose distributions. Tissue equivalent ionization chambers and an ionization chamber array were used for point dose and planar dose distribution comparisons with calculated values. Validation plans were delivered to water and virtual water phantoms using TG-119 measurement points and evaluation techniques. Photon and neutron doses were evaluated both inside and outside the target volume for a typical IMNRT plan to determine effects of intensity modulation on the photon dose component. Monitor unit linearity and effects of beam current and gantry angle on output were investigated, and an independent validation of neutron dosimetry was obtained. While IMNRT plan quality is superior to conventional fast neutron therapy plans for clinical sites such as prostate and head and neck, it is inferior to photon IMRT for most TG-119 planning goals, particularly for complex cases. This results significantly from current limitations on the number of segments. Measured and calculated doses for 11 representative plans (six prostate∕five head and neck) agreed to within -0.8 ± 1.4% and 5.0 ± 6.0% within and outside the target, respectively. Nearly all (22∕24) ion chamber point measurements in the two phantom arrangements were within the respective confidence intervals for the quantity [(measured-planned)∕prescription dose] derived in TG-119. Mean differences for all measurements were 0.5% (max = 7.0%) and 1.4% (max = 4.1%) in water and virtual water, respectively. The mean gamma pass rate for all cases was 92.8% (min = 88.6%). These pass rates are lower than typically achieved with photon IMRT, warranting development of a planar dosimetry system designed specifically for IMNRT and∕or the improvement of neutron beam modeling in the penumbral region. The fractional photon dose component did not change significantly in a typical IMNRT plan versus a conventional fast neutron therapy plan, and IMNRT delivery is not expected to significantly alter the RBE. All other commissioning results were considered satisfactory for clinical implementation of IMNRT, including the external neutron dose validation, which agreed with the predicted neutron dose to within 1%. IMNRT has been successfully commissioned for clinical use. While current plan quality is inferior to photon IMRT, it is superior to conventional fast neutron therapy. Ion chamber validation results for IMNRT commissioning are also comparable to those typically achieved with photon IMRT. Gamma pass rates for planar dose distributions are lower than typically observed for photon IMRT but may be improved with improved planar dosimetry equipment and beam modeling techniques. In the meantime, patient-specific quality assurance measurements should rely more heavily on point dose measurements with tissue equivalent ionization chambers. No significant technical impediments are anticipated in the clinical implementation of IMNRT as described here.

  9. 49 CFR 236.905 - Railroad Safety Program Plan (RSPP).

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... to be used in the verification and validation process, consistent with appendix C to this part. The...; and (iv) The identification of the safety assessment process. (2) Design for verification and validation. The RSPP must require the identification of verification and validation methods for the...

  10. 49 CFR 236.905 - Railroad Safety Program Plan (RSPP).

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... to be used in the verification and validation process, consistent with appendix C to this part. The...; and (iv) The identification of the safety assessment process. (2) Design for verification and validation. The RSPP must require the identification of verification and validation methods for the...

  11. 49 CFR 236.905 - Railroad Safety Program Plan (RSPP).

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... to be used in the verification and validation process, consistent with appendix C to this part. The...; and (iv) The identification of the safety assessment process. (2) Design for verification and validation. The RSPP must require the identification of verification and validation methods for the...

  12. 49 CFR 236.905 - Railroad Safety Program Plan (RSPP).

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... to be used in the verification and validation process, consistent with appendix C to this part. The...; and (iv) The identification of the safety assessment process. (2) Design for verification and validation. The RSPP must require the identification of verification and validation methods for the...

  13. Development of Level 1b Calibration and Validation Readiness, Implementation and Management Plans for GOES-R

    NASA Technical Reports Server (NTRS)

    Kunkee, David B.; Farley, Robert W.; Kwan, Betty P.; Hecht, James H.; Walterscheid, Richard L.; Claudepierre, Seth G.; Bishop, Rebecca L.; Gelinas, Lynette J.; Deluccia, Frank J.

    2017-01-01

    A complement of Readiness, Implementation and Management Plans (RIMPs) to facilitate management of post-launch product test activities for the official Geostationary Operational Environmental Satellite (GOES-R) Level 1b (L1b) products have been developed and documented. Separate plans have been created for each of the GOES-R sensors including: the Advanced Baseline Imager (ABI), the Extreme ultraviolet and X-ray Irradiance Sensors (EXIS), Geostationary Lightning Mapper (GLM), GOES-R Magnetometer (MAG), the Space Environment In-Situ Suite (SEISS), and the Solar Ultraviolet Imager (SUVI). The GOES-R program has implemented these RIMPs in order to address the full scope of CalVal activities required for a successful demonstration of GOES-R L1b data product quality throughout the three validation stages: Beta, Provisional and Full Validation. For each product maturity level, the RIMPs include specific performance criteria and required artifacts that provide evidence a given validation stage has been reached, the timing when each stage will be complete, a description of every applicable Post-Launch Product Test (PLPT), roles and responsibilities of personnel, upstream dependencies, and analysis methods and tools to be employed during validation. Instrument level Post-Launch Tests (PLTs) are also referenced and apply primarily to functional check-out of the instruments.

  14. Translation, adaptation and validation the contents of the Diabetes Medical Management Plan for the Brazilian context

    PubMed Central

    Torres, Heloísa de Carvalho; Chaves, Fernanda Figueredo; da Silva, Daniel Dutra Romualdo; Bosco, Adriana Aparecida; Gabriel, Beatriz Diniz; Reis, Ilka Afonso; Rodrigues, Júlia Santos Nunes; Pagano, Adriana Silvina

    2016-01-01

    ABSTRACT Objective: to translate, adapt and validate the contents of the Diabetes Medical Management Plan for the Brazilian context. This protocol was developed by the American Diabetes Association and guides the procedure of educators for the care of children and adolescents with diabetes in schools. Method: this methodological study was conducted in four stages: initial translation, synthesis of initial translation, back translation and content validation by an expert committee, composed of 94 specialists (29 applied linguists and 65 health professionals), for evaluation of the translated version through an online questionnaire. The concordance level of the judges was calculated based on the Content Validity Index. Data were exported into the R program for statistical analysis: Results: the evaluation of the instrument showed good concordance between the judges of the Health and Applied Linguistics areas, with a mean content validity index of 0.9 and 0.89, respectively, and slight variability of the index between groups (difference of less than 0.01). The items in the translated version, evaluated as unsatisfactory by the judges, were reformulated based on the considerations of the professionals of each group. Conclusion: a Brazilian version of Diabetes Medical Management Plan was constructed, called the Plano de Manejo do Diabetes na Escola. PMID:27508911

  15. WEC-SIM Validation Testing Plan FY14 Q4.

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Ruehl, Kelley Michelle

    2016-02-01

    The WEC-Sim project is currently on track, having met both the SNL and NREL FY14 Milestones, as shown in Table 1 and Table 2. This is also reflected in the Gantt chart uploaded to the WEC-Sim SharePoint site in the FY14 Q4 Deliverables folder. The work completed in FY14 includes code verification through code-to-code comparison (FY14 Q1 and Q2), preliminary code validation through comparison to experimental data (FY14 Q2 and Q3), presentation and publication of the WEC-Sim project at OMAE 2014 [1], [2], [3] and GMREC/METS 2014 [4] (FY14 Q3), WEC-Sim code development and public open-source release (FY14 Q3), andmore » development of a preliminary WEC-Sim validation test plan (FY14 Q4). This report presents the preliminary Validation Testing Plan developed in FY14 Q4. The validation test effort started in FY14 Q4 and will go on through FY15. Thus far the team has developed a device selection method, selected a device, and placed a contract with the testing facility, established several collaborations including industry contacts, and have working ideas on the testing details such as scaling, device design, and test conditions.« less

  16. Remembering the past and planning for the future in rats

    PubMed Central

    Crystal, Jonathon D.

    2012-01-01

    A growing body of research suggests that rats represent and remember specific earlier events from the past. An important criterion for validating a rodent model of episodic memory is to establish that the content of the representation is about a specific event in the past rather than vague information about remoteness. Recent evidence suggests that rats may also represent events that are anticipated to occur in the future. An important capacity afforded by a representation of the future is the ability to plan for the occurrence of a future event. However, relatively little is known about the content of represented future events and the cognitive mechanisms that may support planning. This article reviews evidence that rats remember specific earlier events from the past, represent events that are anticipated to ccur in the future, and develops criteria for validating a rodent model of future planning. These criteria include representing a specific time in the future, the ability to temporarily disengage from a plan and reactivate the plan at an appropriate time in the future, and flexibility to deploy a plan in novel conditions. PMID:23219951

  17. A global quality assurance system for personalized radiation therapy treatment planning for the prostate (or other sites)

    NASA Astrophysics Data System (ADS)

    Nwankwo, Obioma; Sihono, Dwi Seno K.; Schneider, Frank; Wenz, Frederik

    2014-09-01

    Introduction: the quality of radiotherapy treatment plans varies across institutions and depends on the experience of the planner. For the purpose of intra- and inter-institutional homogenization of treatment plan quality, we present an algorithm that learns the organs-at-risk (OARs) sparing patterns from a database of high quality plans. Thereafter, the algorithm predicts the dose that similar organs will receive in future radiotherapy plans prior to treatment planning on the basis of the anatomies of the organs. The predicted dose provides the basis for the individualized specification of planning objectives, and for the objective assessment of the quality of radiotherapy plans. Materials and method: one hundred and twenty eight (128) Volumetric Modulated Arc Therapy (VMAT) plans were selected from a database of prostate cancer plans. The plans were divided into two groups, namely a training set that is made up of 95 plans and a validation set that consists of 33 plans. A multivariate analysis technique was used to determine the relationships between the positions of voxels and their dose. This information was used to predict the likely sparing of the OARs of the plans of the validation set. The predicted doses were visually and quantitatively compared to the reference data using dose volume histograms, the 3D dose distribution, and a novel evaluation metric that is based on the dose different test. Results: a voxel of the bladder on the average receives a higher dose than a voxel of the rectum in optimized radiotherapy plans for the treatment of prostate cancer in our institution if both voxels are at the same distance to the PTV. Based on our evaluation metric, the predicted and reference dose to the bladder agree to within 5% of the prescribed dose to the PTV in 18 out of 33 cases, while the predicted and reference doses to the rectum agree to within 5% in 28 out of the 33 plans of the validation set. Conclusion: We have described a method to predict the likely dose that OARs will receive before treatment planning. This prospective knowledge could be used to implement a global quality assurance system for personalized radiation therapy treatment planning.

  18. Dosimetric accuracy of a treatment planning system for actively scanned proton beams and small target volumes: Monte Carlo and experimental validation

    NASA Astrophysics Data System (ADS)

    Magro, G.; Molinelli, S.; Mairani, A.; Mirandola, A.; Panizza, D.; Russo, S.; Ferrari, A.; Valvo, F.; Fossati, P.; Ciocca, M.

    2015-09-01

    This study was performed to evaluate the accuracy of a commercial treatment planning system (TPS), in optimising proton pencil beam dose distributions for small targets of different sizes (5-30 mm side) located at increasing depths in water. The TPS analytical algorithm was benchmarked against experimental data and the FLUKA Monte Carlo (MC) code, previously validated for the selected beam-line. We tested the Siemens syngo® TPS plan optimisation module for water cubes fixing the configurable parameters at clinical standards, with homogeneous target coverage to a 2 Gy (RBE) dose prescription as unique goal. Plans were delivered and the dose at each volume centre was measured in water with a calibrated PTW Advanced Markus® chamber. An EBT3® film was also positioned at the phantom entrance window for the acquisition of 2D dose maps. Discrepancies between TPS calculated and MC simulated values were mainly due to the different lateral spread modeling and resulted in being related to the field-to-spot size ratio. The accuracy of the TPS was proved to be clinically acceptable in all cases but very small and shallow volumes. In this contest, the use of MC to validate TPS results proved to be a reliable procedure for pre-treatment plan verification.

  19. Dosimetric accuracy of a treatment planning system for actively scanned proton beams and small target volumes: Monte Carlo and experimental validation.

    PubMed

    Magro, G; Molinelli, S; Mairani, A; Mirandola, A; Panizza, D; Russo, S; Ferrari, A; Valvo, F; Fossati, P; Ciocca, M

    2015-09-07

    This study was performed to evaluate the accuracy of a commercial treatment planning system (TPS), in optimising proton pencil beam dose distributions for small targets of different sizes (5-30 mm side) located at increasing depths in water. The TPS analytical algorithm was benchmarked against experimental data and the FLUKA Monte Carlo (MC) code, previously validated for the selected beam-line. We tested the Siemens syngo(®) TPS plan optimisation module for water cubes fixing the configurable parameters at clinical standards, with homogeneous target coverage to a 2 Gy (RBE) dose prescription as unique goal. Plans were delivered and the dose at each volume centre was measured in water with a calibrated PTW Advanced Markus(®) chamber. An EBT3(®) film was also positioned at the phantom entrance window for the acquisition of 2D dose maps. Discrepancies between TPS calculated and MC simulated values were mainly due to the different lateral spread modeling and resulted in being related to the field-to-spot size ratio. The accuracy of the TPS was proved to be clinically acceptable in all cases but very small and shallow volumes. In this contest, the use of MC to validate TPS results proved to be a reliable procedure for pre-treatment plan verification.

  20. Pre-implementation studies of a workforce planning tool for nurse staffing and human resource management in university hospitals.

    PubMed

    van Oostveen, Catharina J; Ubbink, Dirk T; Mens, Marian A; Pompe, Edwin A; Vermeulen, Hester

    2016-03-01

    To investigate the reliability, validity and feasibility of the RAFAELA workforce planning system (including the Oulu patient classification system - OPCq), before deciding on implementation in Dutch hospitals. The complexity of care, budgetary restraints and demand for high-quality patient care have ignited the need for transparent hospital workforce planning. Nurses from 12 wards of two university hospitals were trained to test the reliability of the OPCq by investigating the absolute agreement of nursing care intensity (NCI) measurements among nurses. Validity was tested by assessing whether optimal NCI/nurse ratio, as calculated by a regression analysis in RAFAELA, was realistic. System feasibility was investigated through a questionnaire among all nurses involved. Almost 67 000 NCI measurements were performed between December 2013 and June 2014. Agreement using the OPCq varied between 38% and 91%. For only 1 in 12 wards was the optimal NCI area calculated judged as valid. Although the majority of respondents was positive about the applicability and user-friendliness, RAFAELA was not accepted as useful workforce planning system. Nurses' performance using the RAFAELA system did not warrant its implementation. Hospital managers should first focus on enlarging the readiness of nurses regarding the implementation of a workforce planning system. © 2015 John Wiley & Sons Ltd.

  1. Facility Master Plans: An Essential First Step in the Building Development Process.

    ERIC Educational Resources Information Center

    Wickerham, Wendell E.

    2002-01-01

    Discusses the importance of the facility master plan (FMP) in defining project scope and validating or challenging the work of consultants. Offers three case studies illustrating how facility master plans averted problems or led to unanticipated benefits for the colleges involved. (EV)

  2. Parametric Study of Advanced Mixing of Fuel/Oxidant System in High Speed Gaseous Flows and Experimental Validation Planning

    DTIC Science & Technology

    2001-08-30

    Body with Thermo-Chemical destribution of Heat-Protected System . In: Physical and Gasdynamic Phenomena in Supersonic Flows Over Bodies. Edit. By...Final Report on ISTC Contract # 1809p Parametric Study of Advanced Mixing of Fuel/Oxidant System in High Speed Gaseous Flows and Experimental...of Advanced Mixing of Fuel/Oxidant System in High Speed Gaseous Flows and Experimental Validation Planning 5c. PROGRAM ELEMENT NUMBER 5d. PROJECT

  3. I’m from the Government and I’m Here to Help: Humanitarian Assistance in West Africa

    DTIC Science & Technology

    2017-06-09

    state, then to the international community . The sources in this section address the definition of R2P, the ethical considerations when determining...the ethics and morality of responding to them, and the strategy’s validity and effectiveness compared to the current plan. 15. SUBJECT TERMS Army... ethics and morality of responding to them, and the strategy’s validity and effectiveness compared to the current plan. v ACKNOWLEDGMENTS

  4. 49 CFR 236.905 - Railroad Safety Program Plan (RSPP).

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... validation. The RSPP must require the identification of verification and validation methods for the... to be used in the verification and validation process, consistent with appendix C to this part. The... information. (3) If no action is taken on the petition within 180 days, the petition remains pending for...

  5. 45 CFR 153.620 - Compliance with risk adjustment standards.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... with risk adjustment standards. (a) Issuer support of data validation. An issuer that offers risk adjustment covered plans must comply with any data validation requests by the State or HHS on behalf of the... must retain any information requested to support risk adjustment data validation for a period of at...

  6. 45 CFR 153.620 - Compliance with risk adjustment standards.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... with risk adjustment standards. (a) Issuer support of data validation. An issuer that offers risk adjustment covered plans must comply with any data validation requests by the State or HHS on behalf of the... must retain any information requested to support risk adjustment data validation for a period of at...

  7. The Optimal Screening for Prediction of Referral and Outcome (OSPRO) in patients with musculoskeletal pain conditions: a longitudinal validation cohort from the USA

    PubMed Central

    George, Steven Z; Beneciuk, Jason M; Lentz, Trevor A; Wu, Samuel S

    2017-01-01

    Purpose There is an increased need for determining which patients with musculoskeletal pain benefit from additional diagnostic testing or psychologically informed intervention. The Optimal Screening for Prediction of Referral and Outcome (OSPRO) cohort studies were designed to develop and validate standard assessment tools for review of systems and yellow flags. This cohort profile paper provides a description of and future plans for the validation cohort. Participants Patients (n=440) with primary complaint of spine, shoulder or knee pain were recruited into the OSPRO validation cohort via a national Orthopaedic Physical Therapy-Investigative Network. Patients were followed up at 4 weeks, 6 months and 12 months for pain, functional status and quality of life outcomes. Healthcare utilisation outcomes were also collected at 6 and 12 months. Findings to date There are no longitudinal findings reported to date from the ongoing OSPRO validation cohort. The previously completed cross-sectional OSPRO development cohort yielded two assessment tools that were investigated in the validation cohort. Future plans Follow-up data collection was completed in January 2017. Primary analyses will investigate how accurately the OSPRO review of systems and yellow flag tools predict 12-month pain, functional status, quality of life and healthcare utilisation outcomes. Planned secondary analyses include prediction of pain interference and/or development of chronic pain, investigation of treatment expectation on patient outcomes and analysis of patient satisfaction following an episode of physical therapy. Trial registration number The OSPRO validation cohort was not registered. PMID:28600371

  8. Improvement of Experiment Planning as an Important Precondition for the Quality of Educational Research

    ERIC Educational Resources Information Center

    Rutkiene, Ausra; Tereseviciene, Margarita

    2010-01-01

    The article presents the stages of the experiment planning that are necessary to ensure the validity and reliability of it. The research data reveal that doctoral students of Educational Research approach the planning of the experiment as the planning of the whole dissertation research; and the experiment as a research method is often confused…

  9. Quality assurance for online adapted treatment plans: Benchmarking and delivery monitoring simulation

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Li, Taoran, E-mail: taoran.li.duke@gmail.com; Wu, Qiuwen; Yang, Yun

    Purpose: An important challenge facing online adaptive radiation therapy is the development of feasible and efficient quality assurance (QA). This project aimed to validate the deliverability of online adapted plans and develop a proof-of-concept online delivery monitoring system for online adaptive radiation therapy QA. Methods: The first part of this project benchmarked automatically online adapted prostate treatment plans using traditional portal dosimetry IMRT QA. The portal dosimetry QA results of online adapted plans were compared to original (unadapted) plans as well as randomly selected prostate IMRT plans from our clinic. In the second part, an online delivery monitoring system wasmore » designed and validated via a simulated treatment with intentional multileaf collimator (MLC) errors. This system was based on inputs from the dynamic machine information (DMI), which continuously reports actual MLC positions and machine monitor units (MUs) at intervals of 50 ms or less during delivery. Based on the DMI, the system performed two levels of monitoring/verification during the delivery: (1) dynamic monitoring of cumulative fluence errors resulting from leaf position deviations and visualization using fluence error maps (FEMs); and (2) verification of MLC positions against the treatment plan for potential errors in MLC motion and data transfer at each control point. Validation of the online delivery monitoring system was performed by introducing intentional systematic MLC errors (ranging from 0.5 to 2 mm) to the DMI files for both leaf banks. These DMI files were analyzed by the proposed system to evaluate the system’s performance in quantifying errors and revealing the source of errors, as well as to understand patterns in the FEMs. In addition, FEMs from 210 actual prostate IMRT beams were analyzed using the proposed system to further validate its ability to catch and identify errors, as well as establish error magnitude baselines for prostate IMRT delivery. Results: Online adapted plans were found to have similar delivery accuracy in comparison to clinical IMRT plans when validated with portal dosimetry IMRT QA. FEMs for the simulated deliveries with intentional MLC errors exhibited distinct patterns for different MLC error magnitudes and directions, indicating that the proposed delivery monitoring system is highly specific in detecting the source of errors. Implementing the proposed QA system for online adapted plans revealed excellent delivery accuracy: over 99% of leaf position differences were within 0.5 mm, and >99% of pixels in the FEMs had fluence errors within 0.5 MU. Patterns present in the FEMs and MLC control point analysis for actual patient cases agreed with the error pattern analysis results, further validating the system’s ability to reveal and differentiate MLC deviations. Calculation of the fluence map based on the DMI was performed within 2 ms after receiving each DMI input. Conclusions: The proposed online delivery monitoring system requires minimal additional resources and time commitment to the current clinical workflow while still maintaining high sensitivity to leaf position errors and specificity to error types. The presented online delivery monitoring system therefore represents a promising QA system candidate for online adaptive radiation therapy.« less

  10. Quality assurance for online adapted treatment plans: benchmarking and delivery monitoring simulation.

    PubMed

    Li, Taoran; Wu, Qiuwen; Yang, Yun; Rodrigues, Anna; Yin, Fang-Fang; Jackie Wu, Q

    2015-01-01

    An important challenge facing online adaptive radiation therapy is the development of feasible and efficient quality assurance (QA). This project aimed to validate the deliverability of online adapted plans and develop a proof-of-concept online delivery monitoring system for online adaptive radiation therapy QA. The first part of this project benchmarked automatically online adapted prostate treatment plans using traditional portal dosimetry IMRT QA. The portal dosimetry QA results of online adapted plans were compared to original (unadapted) plans as well as randomly selected prostate IMRT plans from our clinic. In the second part, an online delivery monitoring system was designed and validated via a simulated treatment with intentional multileaf collimator (MLC) errors. This system was based on inputs from the dynamic machine information (DMI), which continuously reports actual MLC positions and machine monitor units (MUs) at intervals of 50 ms or less during delivery. Based on the DMI, the system performed two levels of monitoring/verification during the delivery: (1) dynamic monitoring of cumulative fluence errors resulting from leaf position deviations and visualization using fluence error maps (FEMs); and (2) verification of MLC positions against the treatment plan for potential errors in MLC motion and data transfer at each control point. Validation of the online delivery monitoring system was performed by introducing intentional systematic MLC errors (ranging from 0.5 to 2 mm) to the DMI files for both leaf banks. These DMI files were analyzed by the proposed system to evaluate the system's performance in quantifying errors and revealing the source of errors, as well as to understand patterns in the FEMs. In addition, FEMs from 210 actual prostate IMRT beams were analyzed using the proposed system to further validate its ability to catch and identify errors, as well as establish error magnitude baselines for prostate IMRT delivery. Online adapted plans were found to have similar delivery accuracy in comparison to clinical IMRT plans when validated with portal dosimetry IMRT QA. FEMs for the simulated deliveries with intentional MLC errors exhibited distinct patterns for different MLC error magnitudes and directions, indicating that the proposed delivery monitoring system is highly specific in detecting the source of errors. Implementing the proposed QA system for online adapted plans revealed excellent delivery accuracy: over 99% of leaf position differences were within 0.5 mm, and >99% of pixels in the FEMs had fluence errors within 0.5 MU. Patterns present in the FEMs and MLC control point analysis for actual patient cases agreed with the error pattern analysis results, further validating the system's ability to reveal and differentiate MLC deviations. Calculation of the fluence map based on the DMI was performed within 2 ms after receiving each DMI input. The proposed online delivery monitoring system requires minimal additional resources and time commitment to the current clinical workflow while still maintaining high sensitivity to leaf position errors and specificity to error types. The presented online delivery monitoring system therefore represents a promising QA system candidate for online adaptive radiation therapy.

  11. Pre- and Post-Planned Evaluation: Which Is Preferable?

    ERIC Educational Resources Information Center

    Strasser, Stephen; Deniston, O. Lynn

    1978-01-01

    Factors involved in pre-planned and post-planned evaluation of program effectiveness are compared: (1) reliability and cost of data; (2) internal and external validity; (3) obtrusiveness and threat; (4) goal displacement and program direction. A model to help program administrators decide which approach is more appropriate is presented. (Author/MH)

  12. SPIDERplan: A tool to support decision-making in radiation therapy treatment plan assessment.

    PubMed

    Ventura, Tiago; Lopes, Maria do Carmo; Ferreira, Brigida Costa; Khouri, Leila

    2016-01-01

    In this work, a graphical method for radiotherapy treatment plan assessment and comparison, named SPIDERplan, is proposed. It aims to support plan approval allowing independent and consistent comparisons of different treatment techniques, algorithms or treatment planning systems. Optimized plans from modern radiotherapy are not easy to evaluate and compare because of their inherent multicriterial nature. The clinical decision on the best treatment plan is mostly based on subjective options. SPIDERplan combines a graphical analysis with a scoring index. Customized radar plots based on the categorization of structures into groups and on the determination of individual structures scores are generated. To each group and structure, an angular amplitude is assigned expressing the clinical importance defined by the radiation oncologist. Completing the graphical evaluation, a global plan score, based on the structures score and their clinical weights, is determined. After a necessary clinical validation of the group weights, SPIDERplan efficacy, to compare and rank different plans, was tested through a planning exercise where plans had been generated for a nasal cavity case using different treatment planning systems. SPIDERplan method was applied to the dose metrics achieved by the nasal cavity test plans. The generated diagrams and scores successfully ranked the plans according to the prescribed dose objectives and constraints and the radiation oncologist priorities, after a necessary clinical validation process. SPIDERplan enables a fast and consistent evaluation of plan quality considering all targets and organs at risk.

  13. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Pokhrel, D; Sood, S; Badkul, R

    Purpose: To evaluate the dosimetric performance of X-ray Voxel Monte Carlo(XVMC) algorithm in effort to clinically validate Monte Carlo-approach in heterogeneous liver phantom and liver SBRT plans. Methods: An anthropomorphic RPC liver phantom incorporating a liver structure with two cylindrical targets and organs-at-risk (OARs) was used in phantom validation. Subsequently, five patients with metastatic liver cancer were treated using heterogeneity-corrected pencil-beam(PB-hete)algorithm were analyzed following RTOG-1112 criteria .ITV was delineated on MinIP and OARs were contoured on MeanIP images of 4D-CT. PTV was generated from ITV with 5-10mm uniform margin. Mean PTV was 81.3±46.4cc. Prescription was 30–45Gy in 5 fractions, withmore » at least PTV(D95%)=100%. Hybrid SBRT plans were generated with noncoplanar/3D-conformal arcs plus static-beams at Novalis-TX consisting of HD-MLC and 6MV-SRS. SBRT plans were re-computed using XVMC algorithm utilizing identical beam-geometry, MLC-positions, and monitor units and subsequently compared to clinical PB-hete plans. Results: Our results using RPC liver motion phantom validation were all compliance with MD Anderson standards. However, compared to PB-hete, average target volume encompassed by the prescribed percent isodose (Vp) was 9.1% and 8.5% less for PTV1 and PTV2 with XVMC. For the clinical liver SBRT plans, PB-hete systematically overestimated PTV dose (D95, Dmean and D10) within ±2.0% (p<0.05) compared to XVMC. Mean value of Vp was about 3.8% less with XVMC compared to PB-hete (ranged 2.9–5.7% (p<0.003)). However, mean liver dose (MLD) was 3.2% higher (p<0.003), on average, with XVMC compared to clinical PB-hete (ranged −1.0to−3.9%). OARs doses were statistically insignificant. Conclusion: Results from our XVMC dose calculations and validation study for liver SBRT indicate small-to-moderate under-dosing of the tumor volume when compared to PB-hete. Results were consistent with phantom validation and patients plans. However, Vp was less by up to 5.7% for some liver SBRT patients with XVMC–suggesting under-dosing of the target volume and overdosing of MLD by up to 3.9% occurred with PB-hete plan. These differences between PB-hete and XVMC dose calculations may be of clinical interest.« less

  14. The PLAN score: a bedside prediction rule for death and severe disability following acute ischemic stroke.

    PubMed

    O'Donnell, Martin J; Fang, Jiming; D'Uva, Cami; Saposnik, Gustavo; Gould, Linda; McGrath, Emer; Kapral, Moira K

    2012-11-12

    We sought to develop and validate a simple clinical prediction rule for death and severe disability after acute ischemic stroke that can be used by general clinicians at the time of hospital admission. We analyzed data from a registry of 9847 patients (4943 in the derivation cohort and 4904 in the validation cohort) hospitalized with acute ischemic stroke and included in the Registry of the Canadian Stroke Network (July 1, 2003, to March 31, 2008; 11 regional stroke centers in Ontario, Canada). Outcome measures were 30-day and 1-year mortality and a modified Rankin score of 5 to 6 at discharge. Overall 30-day mortality was 11.5% (derivation cohort) and 13.5% (validation cohort). In the final multivariate model, we included 9 clinical variables that could be categorized as preadmission comorbidities (5 points for preadmission dependence [1.5], cancer [1.5], congestive heart failure [1.0], and atrial fibrillation [1.0]), level of consciousness (5 points for reduced level of consciousness), age (10 points, 1 point/decade), and neurologic focal deficit (5 points for significant/total weakness of the leg [2], weakness of the arm [2], and aphasia or neglect [1]). Maximum score is 25. In the validation cohort, the PLAN score (derived from preadmission comorbidities, level of consciousness, age, and neurologic deficit) predicted 30-day mortality (C statistic, 0.87), death or severe dependence at discharge (0.88), and 1-year mortality (0.84). The PLAN score also predicted favorable outcome (modified Rankin score, 0-2) at discharge (C statistic, 0.80). The PLAN clinical prediction rule identifies patients who will have a poor outcome after hospitalization for acute ischemic stroke. The score comprises clinical data available at the time of admission and may be determined by nonspecialist clinicians. Additional studies to independently validate the PLAN rule in different populations and settings are required.

  15. Thermal System Verification and Model Validation for NASA's Cryogenic Passively Cooled James Webb Space Telescope

    NASA Technical Reports Server (NTRS)

    Cleveland, Paul E.; Parrish, Keith A.

    2005-01-01

    A thorough and unique thermal verification and model validation plan has been developed for NASA s James Webb Space Telescope. The JWST observatory consists of a large deployed aperture optical telescope passively cooled to below 50 Kelvin along with a suite of several instruments passively and actively cooled to below 37 Kelvin and 7 Kelvin, respectively. Passive cooling to these extremely low temperatures is made feasible by the use of a large deployed high efficiency sunshield and an orbit location at the L2 Lagrange point. Another enabling feature is the scale or size of the observatory that allows for large radiator sizes that are compatible with the expected power dissipation of the instruments and large format Mercury Cadmium Telluride (HgCdTe) detector arrays. This passive cooling concept is simple, reliable, and mission enabling when compared to the alternatives of mechanical coolers and stored cryogens. However, these same large scale observatory features, which make passive cooling viable, also prevent the typical flight configuration fully-deployed thermal balance test that is the keystone to most space missions thermal verification plan. JWST is simply too large in its deployed configuration to be properly thermal balance tested in the facilities that currently exist. This reality, when combined with a mission thermal concept with little to no flight heritage, has necessitated the need for a unique and alternative approach to thermal system verification and model validation. This paper describes the thermal verification and model validation plan that has been developed for JWST. The plan relies on judicious use of cryogenic and thermal design margin, a completely independent thermal modeling cross check utilizing different analysis teams and software packages, and finally, a comprehensive set of thermal tests that occur at different levels of JWST assembly. After a brief description of the JWST mission and thermal architecture, a detailed description of the three aspects of the thermal verification and model validation plan is presented.

  16. Using individual patient anatomy to predict protocol compliance for prostate intensity-modulated radiotherapy

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Caine, Hannah; Whalley, Deborah; Kneebone, Andrew

    If a prostate intensity-modulated radiation therapy (IMRT) or volumetric-modulated arc therapy (VMAT) plan has protocol violations, it is often a challenge knowing whether this is due to unfavorable anatomy or suboptimal planning. This study aimed to create a model to predict protocol violations based on patient anatomical variables and their potential relationship to target and organ at risk (OAR) end points in the setting of definitive, dose-escalated IMRT/VMAT prostate planning. Radiotherapy plans from 200 consecutive patients treated with definitive radiation for prostate cancer using IMRT or VMAT were analyzed. The first 100 patient plans (hypothesis-generating cohort) were examined to identifymore » anatomical variables that predict for dosimetric outcome, in particular OAR end points. Variables that scored significance were further assessed for their ability to predict protocol violations using a Classification and Regression Tree (CART) analysis. These results were then validated in a second group of 100 patients (validation cohort). In the initial analysis of the hypothesis-generating cohort, percentage of rectum overlap in the planning target volume (PTV) (%OR) and percentage of bladder overlap in the PTV (%OB) were highlighted as significant predictors of rectal and bladder dosimetry. Lymph node treatment was also significant for bladder outcomes. For the validation cohort, CART analysis showed that %OR of < 6%, 6% to 9% and > 9% predicted a 13%, 63%, and 100% rate of rectal protocol violations respectively. For the bladder, %OB of < 9% vs > 9% is associated with 13% vs 88% rate of bladder constraint violations when lymph nodes were not treated. If nodal irradiation was delivered, plans with a %OB of < 9% had a 59% risk of violations. Percentage of rectum and bladder within the PTV can be used to identify individual plan potential to achieve dose-volume histogram (DVH) constraints. A model based on these factors could be used to reduce planning time, improve work flow, and strengthen plan quality and consistency.« less

  17. Specification and Preliminary Validation of IAT (Integrated Analysis Techniques) Methods: Executive Summary.

    DTIC Science & Technology

    1985-03-01

    conceptual framwork , and preliminary validation of IAT concepts. Planned work for FY85, including more extensive validation, is also described. 20...Developments: Required Capabilities .... ......... 10 2-1 IAT Conceptual Framework - FY85 (FEO) ..... ........... 11 2-2 Recursive Nature of Decomposition...approach: 1) Identify needs & requirements for IAT. 2) Develop IAT conceptual framework. 3) Validate IAT methods. 4) Develop applications materials. To

  18. Automated Planning and Scheduling for Planetary Rover Distributed Operations

    NASA Technical Reports Server (NTRS)

    Backes, Paul G.; Rabideau, Gregg; Tso, Kam S.; Chien, Steve

    1999-01-01

    Automated planning and Scheduling, including automated path planning, has been integrated with an Internet-based distributed operations system for planetary rover operations. The resulting prototype system enables faster generation of valid rover command sequences by a distributed planetary rover operations team. The Web Interface for Telescience (WITS) provides Internet-based distributed collaboration, the Automated Scheduling and Planning Environment (ASPEN) provides automated planning and scheduling, and an automated path planner provided path planning. The system was demonstrated on the Rocky 7 research rover at JPL.

  19. Specific test and evaluation plan

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Hays, W.H.

    1998-03-20

    The purpose of this Specific Test and Evaluation Plan (STEP) is to provide a detailed written plan for the systematic testing of modifications made to the 241-AX-B Valve Pit by the W-314 Project. The STEP develops the outline for test procedures that verify the system`s performance to the established Project design criteria. The STEP is a lower tier document based on the W-314 Test and Evaluation Plan (TEP). Testing includes Validations and Verifications (e.g., Commercial Grade Item Dedication activities), Factory Acceptance Tests (FATs), installation tests and inspections, Construction Acceptance Tests (CATs), Acceptance Test Procedures (ATPs), Pre-Operational Test Procedures (POTPs), andmore » Operational Test Procedures (OTPs). It should be noted that POTPs are not required for testing of the transfer line addition. The STEP will be utilized in conjunction with the TEP for verification and validation.« less

  20. Potential of balloon payloads for in flight validation of direct and nulling interferometry concepts

    NASA Astrophysics Data System (ADS)

    Demangeon, Olivier; Ollivier, Marc; Le Duigou, Jean-Michel; Cassaing, Frédéric; Coudé du Foresto, Vincent; Mourard, Denis; Kern, Pierre; Lam Trong, Tien; Evrard, Jean; Absil, Olivier; Defrere, Denis; Lopez, Bruno

    2010-07-01

    While the question of low cost / low science precursors is raised to validate the concepts of direct and nulling interferometry space missions, balloon payloads offer a real opportunity thanks to their relatively low cost and reduced development plan. Taking into account the flight capabilities of various balloon types, we propose in this paper, several concepts of payloads associated to their flight plan. We also discuss the pros and cons of each concepts in terms of technological and science demonstration power.

  1. Anticipatory Action Planning Increases from 3 to 10 Years of Age in Typically Developing Children

    ERIC Educational Resources Information Center

    Jongbloed-Pereboom, Marjolein; Nijhuis-van der Sanden, Maria W. G.; Saraber-Schiphorst, Nicole; Craje, Celine; Steenbergen, Bert

    2013-01-01

    The primary aim of this study was to assess the development of action planning in a group of typically developing children aged 3 to 10 years (N = 351). The second aim was to assess reliability of the action planning task and to relate the results of the action planning task to results of validated upper limb motor performance tests. Participants…

  2. SU-G-TeP1-06: Fast GPU Framework for Four-Dimensional Monte Carlo in Adaptive Intensity Modulated Proton Therapy (IMPT) for Mobile Tumors

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Botas, P; Heidelberg University, Heidelberg; Grassberger, C

    Purpose: To demonstrate the feasibility of fast Monte Carlo (MC) treatment planning and verification using four-dimensional CT (4DCT) for adaptive IMPT for lung cancer patients. Methods: A validated GPU MC code, gPMC, has been linked to the patient database at our institution and employed to compute the dose-influence matrices (Dij) on the planning CT (pCT). The pCT is an average of the respiratory motion of the patient. The Dijs and patient structures were fed to the optimizer to calculate a treatment plan. To validate the plan against motion, a 4D dose distribution averaged over the possible starting phases is calculatedmore » using the 4DCT and a model of the time structure of the delivered spot map. The dose is accumulated using vector maps created by a GPU-accelerated deformable image registration program (DIR) from each phase of the 4DCT to the reference phase using the B-spline method. Calculation of the Dij matrices and the DIR are performed on a cluster, with each field and vector map calculated in parallel. Results: The Dij production takes ∼3.5s per beamlet for 10e6 protons, depending on the energy and the CT size. Generating a plan with 4D simulation of 1000 spots in 4 fields takes approximately 1h. To test the framework, IMPT plans for 10 lung cancer patients were generated for validation. Differences between the planned and the delivered dose of 19% in dose to some organs at risk and 1.4/21.1% in target mean dose/homogeneity with respect to the plan were observed, suggesting potential for improvement if adaptation is considered. Conclusion: A fast MC treatment planning framework has been developed that allows reliable plan design and verification for mobile targets and adaptation of treatment plans. This will significantly impact treatments for lung tumors, as 4D-MC dose calculations can now become part of planning strategies.« less

  3. Veggie and the VEG-01 Hardware Validation Test

    NASA Technical Reports Server (NTRS)

    Massa, Gioia; wheeler, Ray; Smith, Trent

    2015-01-01

    This presentation presents a brief overview of KSC plant science hardware for space and then details the Veggie hardware and the VEG-01 hardware validation test. The test results and future plans are discussed.

  4. The Hyper-X Flight Systems Validation Program

    NASA Technical Reports Server (NTRS)

    Redifer, Matthew; Lin, Yohan; Bessent, Courtney Amos; Barklow, Carole

    2007-01-01

    For the Hyper-X/X-43A program, the development of a comprehensive validation test plan played an integral part in the success of the mission. The goal was to demonstrate hypersonic propulsion technologies by flight testing an airframe-integrated scramjet engine. Preparation for flight involved both verification and validation testing. By definition, verification is the process of assuring that the product meets design requirements; whereas validation is the process of assuring that the design meets mission requirements for the intended environment. This report presents an overview of the program with emphasis on the validation efforts. It includes topics such as hardware-in-the-loop, failure modes and effects, aircraft-in-the-loop, plugs-out, power characterization, antenna pattern, integration, combined systems, captive carry, and flight testing. Where applicable, test results are also discussed. The report provides a brief description of the flight systems onboard the X-43A research vehicle and an introduction to the ground support equipment required to execute the validation plan. The intent is to provide validation concepts that are applicable to current, follow-on, and next generation vehicles that share the hybrid spacecraft and aircraft characteristics of the Hyper-X vehicle.

  5. Beyond Static and Dynamic Risk Factors: The Incremental Validity of Release Planning for Predicting Sex Offender Recidivism

    ERIC Educational Resources Information Center

    Scoones, Carwyn D.; Willis, Gwenda M.; Grace, Randolph C.

    2012-01-01

    Both desistance research and strengths-based approaches to offender rehabilitation suggest that attempts to reduce sex offender recidivism should attend to an offender's release environment. Recent research has demonstrated that better quality release planning is associated with reduced recidivism; however, whether release planning contributes…

  6. 34 CFR 300.601 - State performance plans and data collection.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... Monitoring, Technical Assistance, and Enforcement § 300.601 State performance plans and data collection. (a... 34 Education 2 2010-07-01 2010-07-01 false State performance plans and data collection. 300.601... described in § 300.600(d). (b) Data collection. (1) Each State must collect valid and reliable information...

  7. Census mapbook for transportation planning.

    DOT National Transportation Integrated Search

    1994-12-01

    Geographic display of Census data in transportation planning and policy decisions are compiled in a report of 49 maps, depicting use of the data in applications such as travel demand model development and model validation, population forecasting, cor...

  8. Relations Between Autonomous Motivation and Leisure-Time Physical Activity Participation: The Mediating Role of Self-Regulation Techniques.

    PubMed

    Nurmi, Johanna; Hagger, Martin S; Haukkala, Ari; Araújo-Soares, Vera; Hankonen, Nelli

    2016-04-01

    This study tested the predictive validity of a multitheory process model in which the effect of autonomous motivation from self-determination theory on physical activity participation is mediated by the adoption of self-regulatory techniques based on control theory. Finnish adolescents (N = 411, aged 17-19) completed a prospective survey including validated measures of the predictors and physical activity, at baseline and after one month (N = 177). A subsample used an accelerometer to objectively measure physical activity and further validate the physical activity self-report assessment tool (n = 44). Autonomous motivation statistically significantly predicted action planning, coping planning, and self-monitoring. Coping planning and self-monitoring mediated the effect of autonomous motivation on physical activity, although self-monitoring was the most prominent. Controlled motivation had no effect on self-regulation techniques or physical activity. Developing interventions that support autonomous motivation for physical activity may foster increased engagement in self-regulation techniques and positively affect physical activity behavior.

  9. Knowledge Acquisition, Validation, and Maintenance in a Planning System for Automated Image Processing

    NASA Technical Reports Server (NTRS)

    Chien, Steve A.

    1996-01-01

    A key obstacle hampering fielding of AI planning applications is the considerable expense of developing, verifying, updating, and maintainting the planning knowledge base (KB). Planning systems must be able to compare favorably in terms of software lifecycle costs to other means of automation such as scripts or rule-based expert systems. This paper describes a planning application of automated imaging processing and our overall approach to knowledge acquisition for this application.

  10. Assessing validity of observational intervention studies - the Benchmarking Controlled Trials.

    PubMed

    Malmivaara, Antti

    2016-09-01

    Benchmarking Controlled Trial (BCT) is a concept which covers all observational studies aiming to assess impact of interventions or health care system features to patients and populations. To create and pilot test a checklist for appraising methodological validity of a BCT. The checklist was created by extracting the most essential elements from the comprehensive set of criteria in the previous paper on BCTs. Also checklists and scientific papers on observational studies and respective systematic reviews were utilized. Ten BCTs published in the Lancet and in the New England Journal of Medicine were used to assess feasibility of the created checklist. The appraised studies seem to have several methodological limitations, some of which could be avoided in planning, conducting and reporting phases of the studies. The checklist can be used for planning, conducting, reporting, reviewing, and critical reading of observational intervention studies. However, the piloted checklist should be validated in further studies. Key messages Benchmarking Controlled Trial (BCT) is a concept which covers all observational studies aiming to assess impact of interventions or health care system features to patients and populations. This paper presents a checklist for appraising methodological validity of BCTs and pilot-tests the checklist with ten BCTs published in leading medical journals. The appraised studies seem to have several methodological limitations, some of which could be avoided in planning, conducting and reporting phases of the studies. The checklist can be used for planning, conducting, reporting, reviewing, and critical reading of observational intervention studies.

  11. WE-DE-201-04: Cross Validation of Knowledge-Based Treatment Planning for Prostate LDR Brachytherapy Using Principle Component Analysis

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Roper, J; Ghavidel, B; Godette, K

    Purpose: To validate a knowledge-based algorithm for prostate LDR brachytherapy treatment planning. Methods: A dataset of 100 cases was compiled from an active prostate seed implant service. Cases were randomized into 10 subsets. For each subset, the 90 remaining library cases were registered to a common reference frame and then characterized on a point by point basis using principle component analysis (PCA). Each test case was converted to PCA vectors using the same process and compared with each library case using a Mahalanobis distance to evaluate similarity. Rank order PCA scores were used to select the best-matched library case. Themore » seed arrangement was extracted from the best-matched case and used as a starting point for planning the test case. Any subsequent modifications were recorded that required input from a treatment planner to achieve V100>95%, V150<60%, V200<20%. To simulate operating-room planning constraints, seed activity was held constant, and the seed count could not increase. Results: The computational time required to register test-case contours and evaluate PCA similarity across the library was 10s. Preliminary analysis of 2 subsets shows that 9 of 20 test cases did not require any seed modifications to obtain an acceptable plan. Five test cases required fewer than 10 seed modifications or a grid shift. Another 5 test cases required approximately 20 seed modifications. An acceptable plan was not achieved for 1 outlier, which was substantially larger than its best match. Modifications took between 5s and 6min. Conclusion: A knowledge-based treatment planning algorithm for prostate LDR brachytherapy is being cross validated using 100 prior cases. Preliminary results suggest that for this size library, acceptable plans can be achieved without planner input in about half of the cases while varying amounts of planner input are needed in remaining cases. Computational time and planning time are compatible with clinical practice.« less

  12. Validation of a hydride generation atomic absorption spectrometry methodology for determination of mercury in fish designed for application in the Brazilian national residue control plan.

    PubMed

    Damin, Isabel C F; Santo, Maria A E; Hennigen, Rosmari; Vargas, Denise M

    2013-01-01

    In the present study, a method for the determination of mercury (Hg) in fish was validated according to ISO/IEC 17025, INMETRO (Brazil), and more recent European recommendations (Commission Decision 2007/333/EC and 2002/657/EC) for implementation in the Brazilian Residue Control Plan (NRCP) in routine applications. The parameters evaluated in the validation were investigated in detail. The results obtained for limit of detection and quantification were respectively, 2.36 and 7.88 μg kg(-1) of Hg. While the recovery varies between 90-96%. The coefficient of variation was of 4.06-8.94% for the repeatability. Furthermore, a comparison using an external proficiency testing scheme was realized. The results of method validated for the determination of the mercury in fish by Hydride generation atomic absorption spectrometry were considered suitable for implementation in routine analysis.

  13. NASA In Situ Data Needs to Support the Operational Calibration and Validation of Ocean Color Satellite Data Products

    NASA Technical Reports Server (NTRS)

    Werdel, P. Jeremy

    2012-01-01

    Calibrating ocean color satellite instruments and validating their data products requires temporal and spatial abundances of high quality in situ oceanographic data. The Consortium for Ocean Leadership Ocean Observing Initiative (OOl) is currently implementing a distributed array of in-water sensors that could provide a significant contribution to future ocean color activities. This workshop will scope the optimal way to use and possibly supplement the planned OOl infrastructure to maximize its utility and relevance for calibration and validation activities that support existing and planned NASA ocean color missions. Here, I present the current state of the art of NASA validation of ocean color data products, with attention to autonomous time-series (e.g., the AERONET -OC network of above-water radiometers), and outline NASA needs for data quality assurance metrics and adherence to community-vetted data collection protocols

  14. CASL Verification and Validation Plan

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Mousseau, Vincent Andrew; Dinh, Nam

    2016-06-30

    This report documents the Consortium for Advanced Simulation of LWRs (CASL) verification and validation plan. The document builds upon input from CASL subject matter experts, most notably the CASL Challenge Problem Product Integrators, CASL Focus Area leaders, and CASL code development and assessment teams. This document will be a living document that will track progress on CASL to do verification and validation for both the CASL codes (including MPACT, CTF, BISON, MAMBA) and for the CASL challenge problems (CIPS, PCI, DNB). The CASL codes and the CASL challenge problems are at differing levels of maturity with respect to validation andmore » verification. The gap analysis will summarize additional work that needs to be done. Additional VVUQ work will be done as resources permit. This report is prepared for the Department of Energy’s (DOE’s) CASL program in support of milestone CASL.P13.02.« less

  15. Impact of computer-based treatment planning software on clinical judgment of dental students for planning prosthodontic rehabilitation

    PubMed Central

    Deshpande, Saee; Chahande, Jayashree

    2014-01-01

    Purpose Successful prosthodontic rehabilitation involves making many interrelated clinical decisions which have an impact on each other. Self-directed computer-based training has been shown to be a very useful tool to develop synthetic and analytical problem-solving skills among students. Thus, a computer-based case study and treatment planning (CSTP) software program was developed which would allow students to work through the process of comprehensive, multidisciplinary treatment planning for patients in a structured and logical manner. The present study was aimed at assessing the effect of this CSTP software on the clinical judgment of dental students while planning prosthodontic rehabilitation and to assess the students’ perceptions about using the program for its intended use. Methods A CSTP software program was developed and validated. The impact of this program on the clinical decision making skills of dental graduates was evaluated by real life patient encounters, using a modified and validated mini-CEX. Students’ perceptions about the program were obtained by a pre-validated feedback questionnaire. Results The faculty assessment scores of clinical judgment improved significantly after the use of this program. The majority of students felt it was an informative, useful, and innovative way of learning and they strongly felt that they had learnt the logical progression of planning, the insight into decision making, and the need for flexibility in treatment planning after using this program. Conclusion CSTP software was well received by the students. There was significant improvement in students’ clinical judgment after using this program. It should thus be envisaged fundamentally as an adjunct to conventional teaching techniques to improve students’ decision making skills and confidence. PMID:25170288

  16. Interactive experimenters' planning procedures and mission control

    NASA Technical Reports Server (NTRS)

    Desjardins, R. L.

    1973-01-01

    The computerized mission control and planning system routinely generates a 24-hour schedule in one hour of operator time by including time dimensions into experimental planning procedures. Planning is validated interactively as it is being generated segment by segment in the frame of specific event times. The planner simply points a light pen at the time mark of interest on the time line for entering specific event times into the schedule.

  17. [Argumentation and construction of validity in Carlos Matus' situational strategic planning].

    PubMed

    Rivera, Francisco Javier Uribe

    2011-09-01

    This study analyzes the process of producing a situational plan according to a benchmark from the philosophy of language and argumentation theory. The basic approach used in the analysis was developed by Carlos Matus. Specifically, the study seeks to identify the inherent argumentative structure and patterns in the situational explanation and regulatory design in a plan's operations, taking argumentative approaches from pragma-dialectics and informal logic as the analytical parameters. The explanation of a health problem is used to illustrate the study. Methodologically, the study is based on the existing literature on the subject and case analyses. The study concludes with the proposition that the use of the specific references means introducing greater rigor into both the analysis of the validity of causal arguments and the design of proposals for interventions, in order for them to be more conclusive in achieving a plan's objectives.

  18. Utility of the Montreal assessment of need questionnaire for community mental health planning.

    PubMed

    Tremblay, Jacques; Bamvita, Jean-Marie; Grenier, Guy; Fleury, Marie-Josée

    2014-09-01

    Needs assessment facilitates mental health services planning, provision, and evaluation. This study aimed to (a) validate a new instrument, the Montreal Assessment of Needs Questionnaire (MANQ), and (b) use this to assess variations and predictors of need (number and seriousness) in 297 individuals with severe mental disorders for 18 months, during implementation of the Quebec Mental Health Action Plan. MANQ internal and external validations were adequate. Variables significantly associated with need number and seriousness variations were used to build multiple linear regression models. Autonomous housing, not receiving welfare, not having consulted a health educator, higher level of help from services, Alcohol Use Disorders Identification Test total score, and social support were associated with decreasing need number and seriousness over time. Having a higher education was also associated with decreasing need number. In a reform context, the MANQ's unique ability to detect rapid improvement in patient needs has usefulness for Quebec mental health planning.

  19. An Overview of NASA's IM&S Verification and Validation Process Plan and Specification for Space Exploration

    NASA Technical Reports Server (NTRS)

    Gravitz, Robert M.; Hale, Joseph

    2006-01-01

    NASA's Exploration Systems Mission Directorate (ESMD) is implementing a management approach for modeling and simulation (M&S) that will provide decision-makers information on the model's fidelity, credibility, and quality. This information will allow the decision-maker to understand the risks involved in using a model's results in the decision-making process. This presentation will discuss NASA's approach for verification and validation (V&V) of its models or simulations supporting space exploration. This presentation will describe NASA's V&V process and the associated M&S verification and validation (V&V) activities required to support the decision-making process. The M&S V&V Plan and V&V Report templates for ESMD will also be illustrated.

  20. Prospective clinical validation of independent DVH prediction for plan QA in automatic treatment planning for prostate cancer patients.

    PubMed

    Wang, Yibing; Heijmen, Ben J M; Petit, Steven F

    2017-12-01

    To prospectively investigate the use of an independent DVH prediction tool to detect outliers in the quality of fully automatically generated treatment plans for prostate cancer patients. A plan QA tool was developed to predict rectum, anus and bladder DVHs, based on overlap volume histograms and principal component analysis (PCA). The tool was trained with 22 automatically generated, clinical plans, and independently validated with 21 plans. Its use was prospectively investigated for 50 new plans by replanning in case of detected outliers. For rectum D mean , V 65Gy , V 75Gy , anus D mean , and bladder D mean , the difference between predicted and achieved was within 0.4 Gy or 0.3% (SD within 1.8 Gy or 1.3%). Thirteen detected outliers were re-planned, leading to moderate but statistically significant improvements (mean, max): rectum D mean (1.3 Gy, 3.4 Gy), V 65Gy (2.7%, 4.2%), anus D mean (1.6 Gy, 6.9 Gy), and bladder D mean (1.5 Gy, 5.1 Gy). The rectum V 75Gy of the new plans slightly increased (0.2%, p = 0.087). A high accuracy DVH prediction tool was developed and used for independent QA of automatically generated plans. In 28% of plans, minor dosimetric deviations were observed that could be improved by plan adjustments. Larger gains are expected for manually generated plans. Copyright © 2017 Elsevier B.V. All rights reserved.

  1. Test/QA plan for the validation of the verification protocol for high speed pesticide spray drift reduction technologies for row and field crops

    EPA Science Inventory

    This test/QA plan for evaluation the generic test protocol for high speed wind tunnel, representing aerial application, pesticide spray drift reduction technologies (DRT) for row and field crops is in conformance with EPA Requirements for Quality Assurance Project Plans (EPA QA/R...

  2. Test/QA plan for the validation of the verification protocol for low speed pesticide spray drift reduction technologies for row and field crops

    EPA Science Inventory

    This test/QA plan for evaluation the generic test protocol for high speed wind tunnel, representing aerial application, pesticide spray drift reduction technologies (DRT) for row and field crops is in conformance with EPA Requirements for Quality Assurance Project Plans (EPA QA/R...

  3. Clinical implementation of a knowledge based planning tool for prostate VMAT.

    PubMed

    Powis, Richard; Bird, Andrew; Brennan, Matthew; Hinks, Susan; Newman, Hannah; Reed, Katie; Sage, John; Webster, Gareth

    2017-05-08

    A knowledge based planning tool has been developed and implemented for prostate VMAT radiotherapy plans providing a target average rectum dose value based on previously achievable values for similar rectum/PTV overlap. The purpose of this planning tool is to highlight sub-optimal clinical plans and to improve plan quality and consistency. A historical cohort of 97 VMAT prostate plans was interrogated using a RayStation script and used to develop a local model for predicting optimum average rectum dose based on individual anatomy. A preliminary validation study was performed whereby historical plans identified as "optimal" and "sub-optimal" by the local model were replanned in a blinded study by four experienced planners and compared to the original clinical plan to assess whether any improvement in rectum dose was observed. The predictive model was then incorporated into a RayStation script and used as part of the clinical planning process. Planners were asked to use the script during planning to provide a patient specific prediction for optimum average rectum dose and to optimise the plan accordingly. Plans identified as "sub-optimal" in the validation study observed a statistically significant improvement in average rectum dose compared to the clinical plan when replanned whereas plans that were identified as "optimal" observed no improvement when replanned. This provided confidence that the local model can identify plans that were suboptimal in terms of rectal sparing. Clinical implementation of the knowledge based planning tool reduced the population-averaged mean rectum dose by 5.6Gy. There was a small but statistically significant increase in total MU and femoral head dose and a reduction in conformity index. These did not affect the clinical acceptability of the plans and no significant changes to other plan quality metrics were observed. The knowledge-based planning tool has enabled substantial reductions in population-averaged mean rectum dose for prostate VMAT patients. This suggests plans are improved when planners receive quantitative feedback on plan quality against historical data.

  4. 45 CFR 261.63 - When is a State's Work Verification Plan due?

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... Plan for validating work activities reported in the TANF Data Report and, if applicable, the SSP-MOE... procedures for TANF or SSP-MOE work activities or its internal controls for ensuring a consistent measurement...

  5. Development and validation of a treatment planning model for magnetic nanoparticle hyperthermia cancer therapy

    NASA Astrophysics Data System (ADS)

    Stigliano, Robert Vincent

    The use of magnetic nanoparticles (mNPs) to induce local hyperthermia has been emerging in recent years as a promising cancer therapy, in both a stand-alone and combination treatment setting, including surgery radiation and chemotherapy. The mNP solution can be injected either directly into the tumor, or administered intravenously. Studies have shown that some cancer cells associate with, internalize, and aggregate mNPs more preferentially than normal cells, with and without antibody targeting. Once the mNPs are delivered inside the cells, a low frequency (30-300kHz) alternating electromagnetic field is used to activate the mNPs. The nanoparticles absorb the applied field and provide localized heat generation at nano-micron scales. Treatment planning models have been shown to improve treatment efficacy in radiation therapy by limiting normal tissue damage while maximizing dose to the tumor. To date, there does not exist a clinical treatment planning model for magnetic nanoparticle hyperthermia which is robust, validated, and commercially available. The focus of this research is on the development and experimental validation of a treatment planning model, consisting of a coupled electromagnetic and thermal model that predicts dynamic thermal distributions during treatment. When allowed to incubate, the mNPs are often sequestered by cancer cells and packed into endosomes. The proximity of the mNPs has a strong influence on their ability to heat due to interparticle magnetic interaction effects. A model of mNP heating which takes into account the effects of magnetic interaction was developed, and validated against experimental data. An animal study in mice was conducted to determine the effects of mNP solution injection duration and PEGylation on macroscale mNP distribution within the tumor, in order to further inform the treatment planning model and future experimental technique. In clinical applications, a critical limiting factor for the maximum applied field is the heating caused by eddy currents, which are induced in the noncancerous tissue. Phantom studies were conducted to validate the ability of the model to accurately predict eddy current heating in the case of zero blood perfusion, and preliminary data was collected to show the validity of the model in live mice to incorporate blood perfusion.

  6. Implementation of the validation testing in MPPG 5.a "Commissioning and QA of treatment planning dose calculations-megavoltage photon and electron beams".

    PubMed

    Jacqmin, Dustin J; Bredfeldt, Jeremy S; Frigo, Sean P; Smilowitz, Jennifer B

    2017-01-01

    The AAPM Medical Physics Practice Guideline (MPPG) 5.a provides concise guidance on the commissioning and QA of beam modeling and dose calculation in radiotherapy treatment planning systems. This work discusses the implementation of the validation testing recommended in MPPG 5.a at two institutions. The two institutions worked collaboratively to create a common set of treatment fields and analysis tools to deliver and analyze the validation tests. This included the development of a novel, open-source software tool to compare scanning water tank measurements to 3D DICOM-RT Dose distributions. Dose calculation algorithms in both Pinnacle and Eclipse were tested with MPPG 5.a to validate the modeling of Varian TrueBeam linear accelerators. The validation process resulted in more than 200 water tank scans and more than 50 point measurements per institution, each of which was compared to a dose calculation from the institution's treatment planning system (TPS). Overall, the validation testing recommended in MPPG 5.a took approximately 79 person-hours for a machine with four photon and five electron energies for a single TPS. Of the 79 person-hours, 26 person-hours required time on the machine, and the remainder involved preparation and analysis. The basic photon, electron, and heterogeneity correction tests were evaluated with the tolerances in MPPG 5.a, and the tolerances were met for all tests. The MPPG 5.a evaluation criteria were used to assess the small field and IMRT/VMAT validation tests. Both institutions found the use of MPPG 5.a to be a valuable resource during the commissioning process. The validation testing in MPPG 5.a showed the strengths and limitations of the TPS models. In addition, the data collected during the validation testing is useful for routine QA of the TPS, validation of software upgrades, and commissioning of new algorithms. © 2016 The Authors. Journal of Applied Clinical Medical Physics published by Wiley Periodicals, Inc. on behalf of American Association of Physicists in Medicine.

  7. Dosimetric validation for an automatic brain metastases planning software using single-isocenter dynamic conformal arcsDosimetric validation for an automatic brain metastases planning software using single-isocenter dynamic conformal arcs.

    PubMed

    Liu, Haisong; Li, Jun; Pappas, Evangelos; Andrews, David; Evans, James; Werner-Wasik, Maria; Yu, Yan; Dicker, Adam; Shi, Wenyin

    2016-09-08

    An automatic brain-metastases planning (ABMP) software has been installed in our institution. It is dedicated for treating multiple brain metastases with radiosurgery on linear accelerators (linacs) using a single-setup isocenter with noncoplanar dynamic conformal arcs. This study is to validate the calculated absolute dose and dose distribution of ABMP. Three types of measurements were performed to validate the planning software: 1, dual micro ion chambers were used with an acrylic phantom to measure the absolute dose; 2, a 3D cylindrical phantom with dual diode array was used to evaluate 2D dose distribution and point dose for smaller targets; and 3, a 3D pseudo-in vivo patient-specific phantom filled with polymer gels was used to evaluate the accuracy of 3D dose distribution and radia-tion delivery. Micro chamber measurement of two targets (volumes of 1.2 cc and 0.9 cc, respectively) showed that the percentage differences of the absolute dose at both targets were less than 1%. Averaged GI passing rate of five different plans measured with the diode array phantom was above 98%, using criteria of 3% dose difference, 1 mm distance to agreement (DTA), and 10% low-dose threshold. 3D gel phantom measurement results demonstrated a 3D displacement of nine targets of 0.7 ± 0.4 mm (range 0.2 ~ 1.1 mm). The averaged two-dimensional (2D) GI passing rate for several region of interests (ROI) on axial slices that encompass each one of the nine targets was above 98% (5% dose difference, 2 mm DTA, and 10% low-dose threshold). Measured D95, the minimum dose that covers 95% of the target volume, of the nine targets was 0.7% less than the calculated D95. Three different types of dosimetric verification methods were used and proved the dose calculation of the new automatic brain metastases planning (ABMP) software was clinical acceptable. The 3D pseudo-in vivo patient-specific gel phantom test also served as an end-to-end test for validating not only the dose calculation, but the treatment delivery accuracy as well. © 2016 The Authors.

  8. Lessons Learned on Operating and Preparing Operations for a Technology Mission from the Perspective of the Earth Observing-1 Mission

    NASA Technical Reports Server (NTRS)

    Mandl, Dan; Howard, Joseph

    2000-01-01

    The New Millennium Program's first Earth-observing mission (EO-1) is a technology validation mission. It is managed by the NASA Goddard Space Flight Center in Greenbelt, Maryland and is scheduled for launch in the summer of 2000. The purpose of this mission is to flight-validate revolutionary technologies that will contribute to the reduction of cost and increase of capabilities for future land imaging missions. In the EO-1 mission, there are five instrument, five spacecraft, and three supporting technologies to flight-validate during a year of operations. EO-1 operations and the accompanying ground system were intended to be simple in order to maintain low operational costs. For purposes of formulating operations, it was initially modeled as a small science mission. However, it quickly evolved into a more complex mission due to the difficulties in effectively integrating all of the validation plans of the individual technologies. As a consequence, more operational support was required to confidently complete the on-orbit validation of the new technologies. This paper will outline the issues and lessons learned applicable to future technology validation missions. Examples of some of these include the following: (1) operational complexity encountered in integrating all of the validation plans into a coherent operational plan, (2) initial desire to run single shift operations subsequently growing to 6 "around-the-clock" operations, (3) managing changes in the technologies that ultimately affected operations, (4) necessity for better team communications within the project to offset the effects of change on the Ground System Developers, Operations Engineers, Integration and Test Engineers, S/C Subsystem Engineers, and Scientists, and (5) the need for a more experienced Flight Operations Team to achieve the necessary operational flexibility. The discussion will conclude by providing several cost comparisons for developing operations from previous missions to EO-1 and discuss some details that might be done differently for future technology validation missions.

  9. Development of the Rational Behavior Inventory: Initial Validity and Reliability

    ERIC Educational Resources Information Center

    Shorkey, Clayton T.; Whiteman, Victor L.

    1977-01-01

    The results of initial validity and reliability studies on the Rational Behavior Inventory are presented. The instrument was developed to be used for assessment, treatment planning, and evaluation of clients by counselors who use Rational Emotive Therapy. (Author/JKS)

  10. GOES-R L1b Readiness Implementation and Management Plan

    NASA Technical Reports Server (NTRS)

    Kunkee, David; Farley, Robert; Kwan, Betty; Walterscheid, Richard; Hecht, James; Claudepierre, Seth.; De Luccia, Frank

    2017-01-01

    A complement of Readiness, Implementation and Management Plans (RIMPs) to facilitate management of post-launch product test activities for the official Geostationary Operational Environmental Satellite (GOES-R) Level 1b (L1b) products have been developed and documented. Separate plans have been created for each of the GOES-R sensors including: the Advanced Baseline Imager (ABI), the Extreme ultraviolet and X-ray Irradiance Sensors (EXIS), Geostationary Lightning Mapper (GLM), GOES-R Magnetometer (MAG), the Space Environment In-Situ Suite (SEISS), and the Solar Ultraviolet Imager (SUVI). The GOES-R program has implemented these RIMPs in order to address the full scope of CalVal activities required for a successful demonstration of GOES-R L1b data product quality throughout the three validation stages: Beta, Provisional and Full Validation. For each product maturity level, the RIMPs include specific performance criteria and required artifacts that provide evidence a given validation stage has been reached, the timing when each stage will be complete, a description of every applicable Post-Launch Product Test (PLPT), roles and responsibilities of personnel, upstream dependencies, and analysis methods and tools to be employed during validation. Instrument level Post-Launch Tests (PLTs) are also referenced and apply primarily to functional check-out of the instruments.

  11. Sci-Fri PM: Radiation Therapy, Planning, Imaging, and Special Techniques - 05: A novel respiratory motion simulation program for VMAT treatment plans: a phantom validation study

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Hubley, Emily; Pierce, Greg; Ploquin, Nicolas

    Purpose: To develop and validate a computational method to simulate craniocaudal respiratory motion in a VMAT treatment plan. Methods: Three 4DCTs of the QUASAR respiratory motion phantom were acquired with a 2cm water-density spherical tumour embedded in cedar to simulate lung. The phantom was oscillating sinusoidally with an amplitude of 2cm and periods of 3, 4, and 5 seconds. An ITV was contoured and 5mm PTV margin was added. High and a low modulation factor VMAT plans were created for each scan. An in-house program was developed to simulate respiratory motion in the treatment plans by shifting the MLC leafmore » positions relative to the phantom. Each plan was delivered to the phantom and the dose was measured using Gafchromic film. The measured and calculated plans were compared using an absolute dose gamma analysis (3%/3mm). Results: The average gamma pass rate for the low modulation plan and high modulation plans were 91.1% and 51.4% respectively. The difference between the high and low modulation plans gamma pass rates is likely related to the different sampling frequency of the respiratory curve and the higher MLC leaf speeds in the high modulation plan. A high modulation plan has a slower gantry speed and therefore samples the breathing cycle at a coarser frequency leading to inaccuracies between the measured and planned doses. Conclusion: A simple program, including a novel method for increasing sampling frequency beyond the control point frequency, has been developed to simulate respiratory motion in VMAT plans by shifting the MLC leaf positions.« less

  12. Quality Assurance Plans under the Renewable Fuel Standard Program

    EPA Pesticide Factsheets

    Quality Assurance Plan or (QAP) is a voluntary program where independent third-parties may audit and verify that RINs have been properly generated and are valid for compliance purposes. RINs verified under a QAP may be purchased by regulated parties.

  13. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Vikraman, S; Ramu, M; Karrthick, Kp

    Purpose: The purpose of this study was to validate the advent of COMPASS 3D dosimetry as a routine pre treatment verification tool with commercially available CMS Monaco and Oncentra Masterplan planning system. Methods: Twenty esophagus patients were selected for this study. All these patients underwent radical VMAT treatment in Elekta Linac and plans were generated in Monaco v5.0 with MonteCarlo(MC) dose calculation algorithm. COMPASS 3D dosimetry comprises an advanced dose calculation algorithm of collapsed cone convolution(CCC). To validate CCC algorithm in COMPASS, The DICOM RT Plans generated using Monaco MC algorithm were transferred to Oncentra Masterplan v4.3 TPS. Only finalmore » dose calculations were performed using CCC algorithm with out optimization in Masterplan planning system. It is proven that MC algorithm is an accurate algorithm and obvious that there will be a difference with MC and CCC algorithms. Hence CCC in COMPASS should be validated with other commercially available CCC algorithm. To use the CCC as pretreatment verification tool with reference to MC generated treatment plans, CCC in OMP and CCC in COMPASS were validated using dose volume based indices such as D98, D95 for target volumes and OAR doses. Results: The point doses for open beams were observed <1% with reference to Monaco MC algorithms. Comparisons of CCC(OMP) Vs CCC(COMPASS) showed a mean difference of 1.82%±1.12SD and 1.65%±0.67SD for D98 and D95 respectively for Target coverage. Maximum point dose of −2.15%±0.60SD difference was observed in target volume. The mean lung dose of −2.68%±1.67SD was noticed between OMP and COMPASS. The maximum point doses for spinal cord were −1.82%±0.287SD. Conclusion: In this study, the accuracy of CCC algorithm in COMPASS 3D dosimetry was validated by compared with CCC algorithm in OMP TPS. Dose calculation in COMPASS is feasible within < 2% in comparison with commercially available TPS algorithms.« less

  14. Alphabus Mechanical Validation Plan and Test Campaign

    NASA Astrophysics Data System (ADS)

    Calvisi, G.; Bonnet, D.; Belliol, P.; Lodereau, P.; Redoundo, R.

    2012-07-01

    A joint team of the two leading European satellite companies (Astrium and Thales Alenia Space) worked with the support of ESA and CNES to define a product line able to efficiently address the upper segment of communications satellites : Alphabus Starting in 2009 and up to 2011 the mechanical validation of the Alphabus platform has been obtained thanks to static tests performed on dedicated static model and to environmental test performed on the first satellite based on Alphabus: Alphasat I-XL. The mechanical validation of the Alphabus platform presented an excellent opportunity to improve the validation and qualification process, with respect to static, sine vibrations, acoustic and L/V shock environment, minimizing recurrent cost of manufacturing, integration and testing. A main driver on mechanical testing is that mechanical acceptance testing at satellite level will be performed with empty tanks due to technical constraints (limitation of existing vibration devices) and programmatic advantages (test risk reduction, test schedule minimization). In this paper the impacts that such testing logic have on validation plan are briefly recalled and its actual application for Alphasat PFM mechanical test campaign is detailed.

  15. Navy Manpower Planning

    DTIC Science & Technology

    2017-03-31

    requirements based on valid, approved workload. • Link peacetime and mobilization manpower requirements. 16 Moreover, the purpose of the SMRD is to... research and policy; energy and environment; manpower management; acquisition and cost; infrastructure; and military readiness . CPP-2017 -U-015038-Final...CNA ANALYSIS & SOLUTIONS 31st March 2017 Subject: NAVY MANPOWER PLANNING MONOGRAPH Navy manpower planning is a rich and complex topic that has a

  16. An Investigation of the Effectiveness and Validity of Planning Time in Speaking Test Tasks

    ERIC Educational Resources Information Center

    Wigglesworth, Gillian; Elder, Cathie

    2010-01-01

    The study described in this article investigated the relationship between three variables in the IELTS oral module--planning, proficiency, and task--and was designed to enhance our understanding of how or whether these variables interact. The study aimed to determine whether differences in performance resulted from 1 or 2 min of planning time. It…

  17. The Personal Development Plan Practice Questionnaire: The Development and Validation of an Instrument to Assess the Employee's Perception of Personal Development Plan Practice

    ERIC Educational Resources Information Center

    Beausaert, Simon; Segers, Mien; Gijselaers, Wim

    2011-01-01

    Confronted with the speed of technological advancements and increasing global competition, organizations have come to realize that their employees' continuous learning drives business success. A popular tool to support and enhance continuous learning is the personal development plan (PDP). Despite its popularity, empirical evidence of the…

  18. Self-guided training for deep brain stimulation planning using objective assessment.

    PubMed

    Holden, Matthew S; Zhao, Yulong; Haegelen, Claire; Essert, Caroline; Fernandez-Vidal, Sara; Bardinet, Eric; Ungi, Tamas; Fichtinger, Gabor; Jannin, Pierre

    2018-04-04

    Deep brain stimulation (DBS) is an increasingly common treatment for neurodegenerative diseases. Neurosurgeons must have thorough procedural, anatomical, and functional knowledge to plan electrode trajectories and thus ensure treatment efficacy and patient safety. Developing this knowledge requires extensive training. We propose a training approach with objective assessment of neurosurgeon proficiency in DBS planning. To assess proficiency, we propose analyzing both the viability of the planned trajectory and the manner in which the operator arrived at the trajectory. To improve understanding, we suggest a self-guided training course for DBS planning using real-time feedback. To validate the proposed measures of proficiency and training course, two experts and six novices followed the training course, and we monitored their proficiency measures throughout. At baseline, experts planned higher quality trajectories and did so more efficiently. As novices progressed through the training course, their proficiency measures increased significantly, trending toward expert measures. We developed and validated measures which reliably discriminate proficiency levels. These measures are integrated into a training course, which quantitatively improves trainee performance. The proposed training course can be used to improve trainees' proficiency, and the quantitative measures allow trainees' progress to be monitored.

  19. Mission Operations of the Mars Exploration Rovers

    NASA Technical Reports Server (NTRS)

    Bass, Deborah; Lauback, Sharon; Mishkin, Andrew; Limonadi, Daniel

    2007-01-01

    A document describes a system of processes involved in planning, commanding, and monitoring operations of the rovers Spirit and Opportunity of the Mars Exploration Rover mission. The system is designed to minimize command turnaround time, given that inherent uncertainties in terrain conditions and in successful completion of planned landed spacecraft motions preclude planning of some spacecraft activities until the results of prior activities are known by the ground-based operations team. The processes are partitioned into those (designated as tactical) that must be tied to the Martian clock and those (designated strategic) that can, without loss, be completed in a more leisurely fashion. The tactical processes include assessment of downlinked data, refinement and validation of activity plans, sequencing of commands, and integration and validation of sequences. Strategic processes include communications planning and generation of long-term activity plans. The primary benefit of this partition is to enable the tactical portion of the team to focus solely on tasks that contribute directly to meeting the deadlines for commanding the rover s each sol (1 sol = 1 Martian day) - achieving a turnaround time of 18 hours or less, while facilitating strategic team interactions with other organizations that do not work on a Mars time schedule.

  20. Assessing validity of observational intervention studies – the Benchmarking Controlled Trials

    PubMed Central

    Malmivaara, Antti

    2016-01-01

    Abstract Background: Benchmarking Controlled Trial (BCT) is a concept which covers all observational studies aiming to assess impact of interventions or health care system features to patients and populations. Aims: To create and pilot test a checklist for appraising methodological validity of a BCT. Methods: The checklist was created by extracting the most essential elements from the comprehensive set of criteria in the previous paper on BCTs. Also checklists and scientific papers on observational studies and respective systematic reviews were utilized. Ten BCTs published in the Lancet and in the New England Journal of Medicine were used to assess feasibility of the created checklist. Results: The appraised studies seem to have several methodological limitations, some of which could be avoided in planning, conducting and reporting phases of the studies. Conclusions: The checklist can be used for planning, conducting, reporting, reviewing, and critical reading of observational intervention studies. However, the piloted checklist should be validated in further studies.Key messagesBenchmarking Controlled Trial (BCT) is a concept which covers all observational studies aiming to assess impact of interventions or health care system features to patients and populations.This paper presents a checklist for appraising methodological validity of BCTs and pilot-tests the checklist with ten BCTs published in leading medical journals. The appraised studies seem to have several methodological limitations, some of which could be avoided in planning, conducting and reporting phases of the studies.The checklist can be used for planning, conducting, reporting, reviewing, and critical reading of observational intervention studies. PMID:27238631

  1. Comparison of pre/post-operative CT image volumes to preoperative digitization of partial hepatectomies: a feasibility study in surgical validation

    NASA Astrophysics Data System (ADS)

    Dumpuri, Prashanth; Clements, Logan W.; Li, Rui; Waite, Jonathan M.; Stefansic, James D.; Geller, David A.; Miga, Michael I.; Dawant, Benoit M.

    2009-02-01

    Preoperative planning combined with image-guidance has shown promise towards increasing the accuracy of liver resection procedures. The purpose of this study was to validate one such preoperative planning tool for four patients undergoing hepatic resection. Preoperative computed tomography (CT) images acquired before surgery were used to identify tumor margins and to plan the surgical approach for resection of these tumors. Surgery was then performed with intraoperative digitization data acquire by an FDA approved image-guided liver surgery system (Pathfinder Therapeutics, Inc., Nashville, TN). Within 5-7 days after surgery, post-operative CT image volumes were acquired. Registration of data within a common coordinate reference was achieved and preoperative plans were compared to the postoperative volumes. Semi-quantitative comparisons are presented in this work and preliminary results indicate that significant liver regeneration/hypertrophy in the postoperative CT images may be present post-operatively. This could challenge pre/post operative CT volume change comparisons as a means to evaluate the accuracy of preoperative surgical plans.

  2. Do older adults with Alzheimer's disease engage in estate planning and advance care planning preparation?

    PubMed

    Choi, Shinae; Kim, Minjung; McDonough, Ian M

    2018-04-18

    This study investigated the estate planning and advance care planning (ACP) of older adults diagnosed with Alzheimer's disease (AD) for the presence of (1) a valid will, (2) a durable power of attorney for health care, and (3) a living will. We analyzed 10,273 adults aged 65 and older from the 2012 Health and Retirement Study (HRS) using multilevel logistic regression. We found that a diagnosis of AD was significantly associated with the ACP variables. Older adults with AD were more likely to assign a durable power of attorney for health care and have a written living will than older adults without an AD diagnosis. However, we found no significant association between a diagnosis of AD and having a valid will. These findings were robust when adjusting for demographic and socioeconomic variables. Other factors decreased engagement in estate planning and ACP, including lower socioeconomic status, being male, and being a minority. Our findings suggest that a diagnosis of AD is associated with more engagement in ACP for individuals and their families, but important barriers exist for people with fewer resources.

  3. Multicentre validation of IMRT pre-treatment verification: comparison of in-house and external audit.

    PubMed

    Jornet, Núria; Carrasco, Pablo; Beltrán, Mercè; Calvo, Juan Francisco; Escudé, Lluís; Hernández, Victor; Quera, Jaume; Sáez, Jordi

    2014-09-01

    We performed a multicentre intercomparison of IMRT optimisation and dose planning and IMRT pre-treatment verification methods and results. The aims were to check consistency between dose plans and to validate whether in-house pre-treatment verification results agreed with those of an external audit. Participating centres used two mock cases (prostate and head and neck) for the intercomparison and audit. Compliance to dosimetric goals and total number of MU per plan were collected. A simple quality index to compare the different plans was proposed. We compared gamma index pass rates using the centre's equipment and methodology to those of an external audit. While for the prostate case, all centres fulfilled the dosimetric goals and plan quality was homogeneous, that was not the case for the head and neck case. The number of MU did not correlate with the plan quality index. Pre-treatment verifications results of the external audit did not agree with those of the in-house measurements for two centres: being within tolerance for in-house measurements and unacceptable for the audit or the other way round. Although all plans fulfilled dosimetric constraints, plan quality is highly dependent on the planner expertise. External audits are an excellent tool to detect errors in IMRT implementation and cannot be replaced by intercomparison using results obtained by centres. Copyright © 2014 Elsevier Ireland Ltd. All rights reserved.

  4. A broad scope knowledge based model for optimization of VMAT in esophageal cancer: validation and assessment of plan quality among different treatment centers.

    PubMed

    Fogliata, Antonella; Nicolini, Giorgia; Clivio, Alessandro; Vanetti, Eugenio; Laksar, Sarbani; Tozzi, Angelo; Scorsetti, Marta; Cozzi, Luca

    2015-10-31

    To evaluate the performance of a broad scope model-based optimisation process for volumetric modulated arc therapy applied to esophageal cancer. A set of 70 previously treated patients in two different institutions, were selected to train a model for the prediction of dose-volume constraints. The model was built with a broad-scope purpose, aiming to be effective for different dose prescriptions and tumour localisations. It was validated on three groups of patients from the same institution and from another clinic not providing patients for the training phase. Comparison of the automated plans was done against reference cases given by the clinically accepted plans. Quantitative improvements (statistically significant for the majority of the analysed dose-volume parameters) were observed between the benchmark and the test plans. Of 624 dose-volume objectives assessed for plan evaluation, in 21 cases (3.3 %) the reference plans failed to respect the constraints while the model-based plans succeeded. Only in 3 cases (<0.5 %) the reference plans passed the criteria while the model-based failed. In 5.3 % of the cases both groups of plans failed and in the remaining cases both passed the tests. Plans were optimised using a broad scope knowledge-based model to determine the dose-volume constraints. The results showed dosimetric improvements when compared to the benchmark data. Particularly the plans optimised for patients from the third centre, not participating to the training, resulted in superior quality. The data suggests that the new engine is reliable and could encourage its application to clinical practice.

  5. SU-F-T-440: The Feasibility Research of Checking Cervical Cancer IMRT Pre- Treatment Dose Verification by Automated Treatment Planning Verification System

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Liu, X; Yin, Y; Lin, X

    Purpose: To assess the preliminary feasibility of automated treatment planning verification system in cervical cancer IMRT pre-treatment dose verification. Methods: The study selected randomly clinical IMRT treatment planning data for twenty patients with cervical cancer, all IMRT plans were divided into 7 fields to meet the dosimetric goals using a commercial treatment planning system(PianncleVersion 9.2and the EclipseVersion 13.5). The plans were exported to the Mobius 3D (M3D)server percentage differences of volume of a region of interest (ROI) and dose calculation of target region and organ at risk were evaluated, in order to validate the accuracy automated treatment planning verification system.more » Results: The difference of volume for Pinnacle to M3D was less than results for Eclipse to M3D in ROI, the biggest difference was 0.22± 0.69%, 3.5±1.89% for Pinnacle and Eclipse respectively. M3D showed slightly better agreement in dose of target and organ at risk compared with TPS. But after recalculating plans by M3D, dose difference for Pinnacle was less than Eclipse on average, results were within 3%. Conclusion: The method of utilizing the automated treatment planning system to validate the accuracy of plans is convenientbut the scope of differences still need more clinical patient cases to determine. At present, it should be used as a secondary check tool to improve safety in the clinical treatment planning.« less

  6. Validating commercial remote sensing and spatial information (CRS&SI) technologies for streamlining environmental and planning processes in transportation projects.

    DOT National Transportation Integrated Search

    2010-03-01

    Transportation corridor-planning processes are well understood, and consensus exists among practitioners : about common practices for stages and tasks included in traditional EIS approaches. However, traditional approaches do : not typically employ f...

  7. Measuring Advance Care Planning: Optimizing the Advance Care Planning Engagement Survey.

    PubMed

    Sudore, Rebecca L; Heyland, Daren K; Barnes, Deborah E; Howard, Michelle; Fassbender, Konrad; Robinson, Carole A; Boscardin, John; You, John J

    2017-04-01

    A validated 82-item Advance Care Planning (ACP) Engagement Survey measures a broad range of behaviors. However, concise surveys are needed. The objective of this study was to validate shorter versions of the survey. The survey included 57 process (e.g., readiness) and 25 action items (e.g., discussions). For item reduction, we systematically eliminated questions based on face validity, item nonresponse, redundancy, ceiling effects, and factor analysis. We assessed internal consistency (Cronbach's alpha) and construct validity with cross-sectional correlations and the ability of the progressively shorter survey versions to detect change one week after exposure to an ACP intervention (Pearson correlation coefficients). Five hundred one participants (four Canadian and three US sites) were included in item reduction (mean age 69 years [±10], 41% nonwhite). Because of high correlations between readiness and action items, all action items were removed. Because of high correlations and ceiling effects, two process items were removed. Successive factor analysis then created 55-, 34-, 15-, nine-, and four-item versions; 664 participants (from three US ACP clinical trials) were included in validity analysis (age 65 years [±8], 72% nonwhite, 34% Spanish speaking). Cronbach's alphas were high for all versions (four items 0.84-55 items 0.97). Compared with the original survey, cross-sectional correlations were high (four items 0.85; 55 items 0.97) as were delta correlations (four items 0.68; 55 items 0.93). Shorter versions of the ACP Engagement Survey are valid, internally consistent, and able to detect change across a broad range of ACP behaviors for English and Spanish speakers. Shorter ACP surveys can efficiently measure broad ACP behaviors in research and clinical settings. Published by Elsevier Inc.

  8. Haptic simulation framework for determining virtual dental occlusion.

    PubMed

    Wu, Wen; Chen, Hui; Cen, Yuhai; Hong, Yang; Khambay, Balvinder; Heng, Pheng Ann

    2017-04-01

    The surgical treatment of many dentofacial deformities is often complex due to its three-dimensional nature. To determine the dental occlusion in the most stable position is essential for the success of the treatment. Computer-aided virtual planning on individualized patient-specific 3D model can help formulate the surgical plan and predict the surgical change. However, in current computer-aided planning systems, it is not possible to determine the dental occlusion of the digital models in the intuitive way during virtual surgical planning because of absence of haptic feedback. In this paper, a physically based haptic simulation framework is proposed, which can provide surgeons with the intuitive haptic feedback to determine the dental occlusion of the digital models in their most stable position. To provide the physically realistic force feedback when the dental models contact each other during the searching process, the contact model is proposed to describe the dynamic and collision properties of the dental models during the alignment. The simulated impulse/contact-based forces are integrated into the unified simulation framework. A validation study has been conducted on fifteen sets of virtual dental models chosen at random and covering a wide range of the dental relationships found clinically. The dental occlusions obtained by an expert were employed as a benchmark to compare the virtual occlusion results. The mean translational and angular deviations of the virtual occlusion results from the benchmark were small. The experimental results show the validity of our method. The simulated forces can provide valuable insights to determine the virtual dental occlusion. The findings of this work and the validation of proposed concept lead the way for full virtual surgical planning on patient-specific virtual models allowing fully customized treatment plans for the surgical correction of dentofacial deformities.

  9. Spatial calibration and temporal validation of flow for regional scale hydrologic modeling

    USDA-ARS?s Scientific Manuscript database

    Physically based regional scale hydrologic modeling is gaining importance for planning and management of water resources. Calibration and validation of such regional scale model is necessary before applying it for scenario assessment. However, in most regional scale hydrologic modeling, flow validat...

  10. Autonomously generating operations sequences for a Mars Rover using AI-based planning

    NASA Technical Reports Server (NTRS)

    Sherwood, Rob; Mishkin, Andrew; Estlin, Tara; Chien, Steve; Backes, Paul; Cooper, Brian; Maxwell, Scott; Rabideau, Gregg

    2001-01-01

    This paper discusses a proof-of-concept prototype for ground-based automatic generation of validated rover command sequences from highlevel science and engineering activities. This prototype is based on ASPEN, the Automated Scheduling and Planning Environment. This Artificial Intelligence (AI) based planning and scheduling system will automatically generate a command sequence that will execute within resource constraints and satisfy flight rules.

  11. Field Test of Route Planning Software for Lunar Polar Missions

    NASA Astrophysics Data System (ADS)

    Horchler, A. D.; Cunningham, C.; Jones, H. L.; Arnett, D.; Fang, E.; Amoroso, E.; Otten, N.; Kitchell, F.; Holst, I.; Rock, G.; Whittaker, W.

    2017-10-01

    A novel field test paradigm has been developed to demonstrate and validate route planning software in the stark low-angled light and sweeping shadows a rover would experience at the poles of the Moon. Software, ConOps, and test results are presented.

  12. High resolution ion chamber array delivery quality assurance for robotic radiosurgery: Commissioning and validation.

    PubMed

    Blanck, Oliver; Masi, Laura; Chan, Mark K H; Adamczyk, Sebastian; Albrecht, Christian; Damme, Marie-Christin; Loutfi-Krauss, Britta; Alraun, Manfred; Fehr, Roman; Ramm, Ulla; Siebert, Frank-Andre; Stelljes, Tenzin Sonam; Poppinga, Daniela; Poppe, Björn

    2016-06-01

    High precision radiosurgery demands comprehensive delivery-quality-assurance techniques. The use of a liquid-filled ion-chamber-array for robotic-radiosurgery delivery-quality-assurance was investigated and validated using several test scenarios and routine patient plans. Preliminary evaluation consisted of beam profile validation and analysis of source-detector-distance and beam-incidence-angle response dependence. The delivery-quality-assurance analysis is performed in four steps: (1) Array-to-plan registration, (2) Evaluation with standard Gamma-Index criteria (local-dose-difference⩽2%, distance-to-agreement⩽2mm, pass-rate⩾90%), (3) Dose profile alignment and dose distribution shift until maximum pass-rate is found, and (4) Final evaluation with 1mm distance-to-agreement criterion. Test scenarios consisted of intended phantom misalignments, dose miscalibrations, and undelivered Monitor Units. Preliminary method validation was performed on 55 clinical plans in five institutions. The 1000SRS profile measurements showed sufficient agreement compared with a microDiamond detector for all collimator sizes. The relative response changes can be up to 2.2% per 10cm source-detector-distance change, but remains within 1% for the clinically relevant source-detector-distance range. Planned and measured dose under different beam-incidence-angles showed deviations below 1% for angles between 0° and 80°. Small-intended errors were detected by 1mm distance-to-agreement criterion while 2mm criteria failed to reveal some of these deviations. All analyzed delivery-quality-assurance clinical patient plans were within our tight tolerance criteria. We demonstrated that a high-resolution liquid-filled ion-chamber-array can be suitable for robotic radiosurgery delivery-quality-assurance and that small errors can be detected with tight distance-to-agreement criterion. Further improvement may come from beam specific correction for incidence angle and source-detector-distance response. Copyright © 2016 Associazione Italiana di Fisica Medica. Published by Elsevier Ltd. All rights reserved.

  13. Utility of the Montreal Assessment of Need Questionnaire for Community Mental Health Planning

    PubMed Central

    Tremblay, Jacques; Bamvita, Jean-Marie; Grenier, Guy; Fleury, Marie-Josée

    2014-01-01

    Abstract Needs assessment facilitates mental health services planning, provision, and evaluation. This study aimed to a) validate a new instrument, the Montreal Assessment of Needs Questionnaire (MANQ), and b) use this to assess variations and predictors of need (number and seriousness) in 297 individuals with severe mental disorders for 18 months, during implementation of the Quebec Mental Health Action Plan. MANQ internal and external validations were adequate. Variables significantly associated with need number and seriousness variations were used to build multiple linear regression models. Autonomous housing, not receiving welfare, not having consulted a health educator, higher level of help from services, Alcohol Use Disorders Identification Test total score, and social support were associated with decreasing need number and seriousness over time. Having a higher education was also associated with decreasing need number. In a reform context, the MANQ’s unique ability to detect rapid improvement in patient needs has usefulness for Quebec mental health planning. PMID:25099300

  14. Validation of a sampling plan to generate food composition data.

    PubMed

    Sammán, N C; Gimenez, M A; Bassett, N; Lobo, M O; Marcoleri, M E

    2016-02-15

    A methodology to develop systematic plans for food sampling was proposed. Long life whole and skimmed milk, and sunflower oil were selected to validate the methodology in Argentina. Fatty acid profile in all foods, proximal composition, and calcium's content in milk were determined with AOAC methods. The number of samples (n) was calculated applying Cochran's formula with variation coefficients ⩽12% and an estimate error (r) maximum permissible ⩽5% for calcium content in milks and unsaturated fatty acids in oil. n were 9, 11 and 21 for long life whole and skimmed milk, and sunflower oil respectively. Sample units were randomly collected from production sites and sent to labs. Calculated r with experimental data was ⩽10%, indicating high accuracy in the determination of analyte content of greater variability and reliability of the proposed sampling plan. The methodology is an adequate and useful tool to develop sampling plans for food composition analysis. Copyright © 2015 Elsevier Ltd. All rights reserved.

  15. Development of 3-D Ice Accretion Measurement Method

    NASA Technical Reports Server (NTRS)

    Lee, Sam; Broeren, Andy P.; Addy, Harold E., Jr.; Sills, Robert; Pifer, Ellen M.

    2012-01-01

    A research plan is currently being implemented by NASA to develop and validate the use of a commercial laser scanner to record and archive fully three-dimensional (3-D) ice shapes from an icing wind tunnel. The plan focused specifically upon measuring ice accreted in the NASA Icing Research Tunnel (IRT). The plan was divided into two phases. The first phase was the identification and selection of the laser scanning system and the post-processing software to purchase and develop further. The second phase was the implementation and validation of the selected system through a series of icing and aerodynamic tests. Phase I of the research plan has been completed. It consisted of evaluating several scanning hardware and software systems against an established selection criteria through demonstrations in the IRT. The results of Phase I showed that all of the scanning systems that were evaluated were equally capable of scanning ice shapes. The factors that differentiated the scanners were ease of use and the ability to operate in a wide range of IRT environmental conditions.

  16. Integrated Medical Model Verification, Validation, and Credibility

    NASA Technical Reports Server (NTRS)

    Walton, Marlei; Kerstman, Eric; Foy, Millennia; Shah, Ronak; Saile, Lynn; Boley, Lynn; Butler, Doug; Myers, Jerry

    2014-01-01

    The Integrated Medical Model (IMM) was designed to forecast relative changes for a specified set of crew health and mission success risk metrics by using a probabilistic (stochastic process) model based on historical data, cohort data, and subject matter expert opinion. A probabilistic approach is taken since exact (deterministic) results would not appropriately reflect the uncertainty in the IMM inputs. Once the IMM was conceptualized, a plan was needed to rigorously assess input information, framework and code, and output results of the IMM, and ensure that end user requests and requirements were considered during all stages of model development and implementation. METHODS: In 2008, the IMM team developed a comprehensive verification and validation (VV) plan, which specified internal and external review criteria encompassing 1) verification of data and IMM structure to ensure proper implementation of the IMM, 2) several validation techniques to confirm that the simulation capability of the IMM appropriately represents occurrences and consequences of medical conditions during space missions, and 3) credibility processes to develop user confidence in the information derived from the IMM. When the NASA-STD-7009 (7009) was published, the IMM team updated their verification, validation, and credibility (VVC) project plan to meet 7009 requirements and include 7009 tools in reporting VVC status of the IMM. RESULTS: IMM VVC updates are compiled recurrently and include 7009 Compliance and Credibility matrices, IMM VV Plan status, and a synopsis of any changes or updates to the IMM during the reporting period. Reporting tools have evolved over the lifetime of the IMM project to better communicate VVC status. This has included refining original 7009 methodology with augmentation from the NASA-STD-7009 Guidance Document. End user requests and requirements are being satisfied as evidenced by ISS Program acceptance of IMM risk forecasts, transition to an operational model and simulation tool, and completion of service requests from a broad end user consortium including Operations, Science and Technology Planning, and Exploration Planning. CONCLUSIONS: The VVC approach established by the IMM project of combining the IMM VV Plan with 7009 requirements is comprehensive and includes the involvement of end users at every stage in IMM evolution. Methods and techniques used to quantify the VVC status of the IMM have not only received approval from the local NASA community but have also garnered recognition by other federal agencies seeking to develop similar guidelines in the medical modeling community.

  17. Validation of Fully Automated VMAT Plan Generation for Library-Based Plan-of-the-Day Cervical Cancer Radiotherapy.

    PubMed

    Sharfo, Abdul Wahab M; Breedveld, Sebastiaan; Voet, Peter W J; Heijkoop, Sabrina T; Mens, Jan-Willem M; Hoogeman, Mischa S; Heijmen, Ben J M

    2016-01-01

    To develop and validate fully automated generation of VMAT plan-libraries for plan-of-the-day adaptive radiotherapy in locally-advanced cervical cancer. Our framework for fully automated treatment plan generation (Erasmus-iCycle) was adapted to create dual-arc VMAT treatment plan libraries for cervical cancer patients. For each of 34 patients, automatically generated VMAT plans (autoVMAT) were compared to manually generated, clinically delivered 9-beam IMRT plans (CLINICAL), and to dual-arc VMAT plans generated manually by an expert planner (manVMAT). Furthermore, all plans were benchmarked against 20-beam equi-angular IMRT plans (autoIMRT). For all plans, a PTV coverage of 99.5% by at least 95% of the prescribed dose (46 Gy) had the highest planning priority, followed by minimization of V45Gy for small bowel (SB). Other OARs considered were bladder, rectum, and sigmoid. All plans had a highly similar PTV coverage, within the clinical constraints (above). After plan normalizations for exactly equal median PTV doses in corresponding plans, all evaluated OAR parameters in autoVMAT plans were on average lower than in the CLINICAL plans with an average reduction in SB V45Gy of 34.6% (p<0.001). For 41/44 autoVMAT plans, SB V45Gy was lower than for manVMAT (p<0.001, average reduction 30.3%), while SB V15Gy increased by 2.3% (p = 0.011). AutoIMRT reduced SB V45Gy by another 2.7% compared to autoVMAT, while also resulting in a 9.0% reduction in SB V15Gy (p<0.001), but with a prolonged delivery time. Differences between manVMAT and autoVMAT in bladder, rectal and sigmoid doses were ≤ 1%. Improvements in SB dose delivery with autoVMAT instead of manVMAT were higher for empty bladder PTVs compared to full bladder PTVs, due to differences in concavity of the PTVs. Quality of automatically generated VMAT plans was superior to manually generated plans. Automatic VMAT plan generation for cervical cancer has been implemented in our clinical routine. Due to the achieved workload reduction, extension of plan libraries has become feasible.

  18. Virtual Factory Framework for Supporting Production Planning and Control.

    PubMed

    Kibira, Deogratias; Shao, Guodong

    2017-01-01

    Developing optimal production plans for smart manufacturing systems is challenging because shop floor events change dynamically. A virtual factory incorporating engineering tools, simulation, and optimization generates and communicates performance data to guide wise decision making for different control levels. This paper describes such a platform specifically for production planning. We also discuss verification and validation of the constituent models. A case study of a machine shop is used to demonstrate data generation for production planning in a virtual factory.

  19. 9 CFR 417.4 - Validation, Verification, Reassessment.

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... not have a HACCP plan because a hazard analysis has revealed no food safety hazards that are.... 417.4 Section 417.4 Animals and Animal Products FOOD SAFETY AND INSPECTION SERVICE, DEPARTMENT OF... ACT HAZARD ANALYSIS AND CRITICAL CONTROL POINT (HACCP) SYSTEMS § 417.4 Validation, Verification...

  20. 9 CFR 417.4 - Validation, Verification, Reassessment.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... not have a HACCP plan because a hazard analysis has revealed no food safety hazards that are.... 417.4 Section 417.4 Animals and Animal Products FOOD SAFETY AND INSPECTION SERVICE, DEPARTMENT OF... ACT HAZARD ANALYSIS AND CRITICAL CONTROL POINT (HACCP) SYSTEMS § 417.4 Validation, Verification...

  1. 9 CFR 417.4 - Validation, Verification, Reassessment.

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... analysis. Any establishment that does not have a HACCP plan because a hazard analysis has revealed no food.... 417.4 Section 417.4 Animals and Animal Products FOOD SAFETY AND INSPECTION SERVICE, DEPARTMENT OF... ACT HAZARD ANALYSIS AND CRITICAL CONTROL POINT (HACCP) SYSTEMS § 417.4 Validation, Verification...

  2. 9 CFR 417.4 - Validation, Verification, Reassessment.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... not have a HACCP plan because a hazard analysis has revealed no food safety hazards that are.... 417.4 Section 417.4 Animals and Animal Products FOOD SAFETY AND INSPECTION SERVICE, DEPARTMENT OF... ACT HAZARD ANALYSIS AND CRITICAL CONTROL POINT (HACCP) SYSTEMS § 417.4 Validation, Verification...

  3. 9 CFR 417.4 - Validation, Verification, Reassessment.

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... analysis. Any establishment that does not have a HACCP plan because a hazard analysis has revealed no food.... 417.4 Section 417.4 Animals and Animal Products FOOD SAFETY AND INSPECTION SERVICE, DEPARTMENT OF... ACT HAZARD ANALYSIS AND CRITICAL CONTROL POINT (HACCP) SYSTEMS § 417.4 Validation, Verification...

  4. ETV/ESTCP Demonstration Plan - Demonstration and Verification of a Turbine Power Generation System Utilizing Renewable Fuel: Landfill Gas

    EPA Science Inventory

    This Test and Quality Assurance Plan (TQAP) provides data quality objections for the success factors that were validated during this demonstration include energy production, emissions and emission reductions compared to alternative systems, economics, and operability, including r...

  5. Management Planning and Control: Supporting Knowledge-Intensive Organizations

    ERIC Educational Resources Information Center

    Herremans, Irene M.; Isaac, Robert G.

    2005-01-01

    Purpose: The purpose of this paper is to develop propositions for empirical validation regarding appropriate management planning and control systems (MPACS) in knowledge-intensive organizations. Design/methodology/approach: The propositions were developed from interviews with members of a knowledge-intensive virtual organization that is known for…

  6. ERCMExpress. Volume 2, Issue 3

    ERIC Educational Resources Information Center

    US Department of Education, 2006

    2006-01-01

    This issue of the Emergency Response and Crisis Management (ERCM) Technical Assistance Center's "ERCMExpress" promotes emergency exercises as an effective way to validate school safety plans. Simulations of emergency situations, or emergency exercises, are integral to a sound school safety plan. They offer opportunities for district and schools to…

  7. A Total Quality-Control Plan with Right-Sized Statistical Quality-Control.

    PubMed

    Westgard, James O

    2017-03-01

    A new Clinical Laboratory Improvement Amendments option for risk-based quality-control (QC) plans became effective in January, 2016. Called an Individualized QC Plan, this option requires the laboratory to perform a risk assessment, develop a QC plan, and implement a QC program to monitor ongoing performance of the QC plan. Difficulties in performing a risk assessment may limit validity of an Individualized QC Plan. A better alternative is to develop a Total QC Plan including a right-sized statistical QC procedure to detect medically important errors. Westgard Sigma Rules provides a simple way to select the right control rules and the right number of control measurements. Copyright © 2016 Elsevier Inc. All rights reserved.

  8. Planning Abilities in Patients with Anorexia Nervosa Compared with Healthy Controls.

    PubMed

    Carral-Fernández, Laura; González-Blanch, César; Goddard, Elizabeth; González-Gómez, Jana; Benito-González, Pilar; Bustamante-Cruz, Encarnación; Gómez Del Barrio, Andrés

    2016-02-01

    Altered cognitive functioning could have an important role in the development and maintenance of Anorexia Nervosa (AN). The majority of previous research has focused on flexibility and global-detail processing. The aim of this study was to explore planning abilities in women with AN. Women with AN (n = 32) were compared to healthy controls (n = 42) using two different types of neuropsychological tasks for the assessment of planning abilities: Tower of London (ToL), a classic measure of planning abilities, and Zoo Map test, a more ecologically valid planning measure. Measures of AN psychopathology, anxiety, depression, and obsessive compulsivity were also collected. The AN group did not differ from controls in the ToL (all p-values p > .05), although they performed significantly worse than controls in the main score of the Zoo Map (p = .02). A worse performance in the Zoo Map test More was associated with more eating disorders (rho = -.44, p = .018) and depressive (rho = -.42, p = .026) symptoms in the AN group. Our study suggests the presence of subtle planning difficulties in women with AN which might be better detected using tasks with increased ecological validity.

  9. Reliability and Validity of Scores on the IFSP Rating Scale

    ERIC Educational Resources Information Center

    Jung, Lee Ann; McWilliam, R. A.

    2005-01-01

    Evidence is presented regarding the construct validity and internal consistency reliability of scores for an investigator-developed individualized family service plan (IFSP) rating scale. One hundred and twenty IFSPs were rated using a 12-item instrument, the IFSP Rating Scale (McWilliam & Jung, 2001). Using principal components factor…

  10. Statistically Valid Planting Trials

    Treesearch

    C. B. Briscoe

    1961-01-01

    More than 100 million tree seedlings are planted each year in Latin America, and at least ten time'that many should be planted Rational control and development of a program of such magnitude require establishing and interpreting carefully planned trial plantings which will yield statistically valid answers to real and important questions. Unfortunately, many...

  11. Soil Moisture Active Passive (SMAP) Calibration and validation plan and current activities

    USDA-ARS?s Scientific Manuscript database

    The primary objective of the SMAP calibration and validation (Cal/Val) program is demonstrating that the science requirements (product accuracy and bias) have been met over the mission life. This begins during pre-launch with activities that contribute to high quality products and establishing post-...

  12. Content Validation of Athletic Therapy Clinical Presentations in Canada

    ERIC Educational Resources Information Center

    Lafave, Mark R.; Yeo, Michelle; Westbrook, Khatija; Valdez, Dennis; Eubank, Breda; McAllister, Jenelle

    2016-01-01

    Context: Competency-based education requires strong planning and a vehicle to deliver and track students' progress across their undergraduate programs. Clinical presentations (CPs) are proposed as 1 method to deliver a competency-based curriculum in a Canadian undergraduate athletic therapy program. Objective: Validation of 253 CPs. Setting:…

  13. Rotorcraft noise

    NASA Technical Reports Server (NTRS)

    Huston, R. J. (Compiler)

    1982-01-01

    The establishment of a realistic plan for NASA and the U.S. helicopter industry to develop a design-for-noise methodology, including plans for the identification and development of promising noise reduction technology was discussed. Topics included: noise reduction techniques, scaling laws, empirical noise prediction, psychoacoustics, and methods of developing and validing noise prediction methods.

  14. Multiple Roles: The Conflicted Realities of Community College Mission Statements

    ERIC Educational Resources Information Center

    Mrozinski, Mark D.

    2010-01-01

    Questions of efficacy have always plagued the use of mission statement as a strategic planning tool. In most planning models, the mission statement serves to clarify goals and guide the formation of strategies. However, little empirical evidence exists validating that mission statements actually improve the performance of organizations, even…

  15. Coaxial cable sensors and sensing instrument for crack detection in bridge structures--phase I : field qualification/validation planning.

    DOT National Transportation Integrated Search

    2009-11-01

    The objectives of this study are to pre-test analyze a decommissioned reinforced concrete (RC) bridge that is selected in consultation with the New York State Department of Transportation (NYSDOT), and design and plan the field tests of the bridge fo...

  16. Planned Missing Data Designs for Research in Cognitive Development

    ERIC Educational Resources Information Center

    Rhemtulla, Mijke; Little, Todd D.

    2012-01-01

    Data collection can be the most time- and cost-intensive part of developmental research. This article describes some long-proposed but little-used research designs that have the potential to maximize data quality (reliability and validity) while minimizing research cost. In "planned missing data designs", missing data are used…

  17. Tailoring the Interview Process for More Effective Personnel Selection.

    ERIC Educational Resources Information Center

    Saville, Anthony

    Structuring the initial teacher employment interview adds validity to selection and appropriately utilizes human resources. Five aspects of an effective interview program include: (1) developing a job analysis plan; (2) reviewing the applications; (3) planning for the interview; (4) the interview instrument; and (5) legal implications. An…

  18. Alternative sample sizes for verification dose experiments and dose audits

    NASA Astrophysics Data System (ADS)

    Taylor, W. A.; Hansen, J. M.

    1999-01-01

    ISO 11137 (1995), "Sterilization of Health Care Products—Requirements for Validation and Routine Control—Radiation Sterilization", provides sampling plans for performing initial verification dose experiments and quarterly dose audits. Alternative sampling plans are presented which provide equivalent protection. These sampling plans can significantly reduce the cost of testing. These alternative sampling plans have been included in a draft ISO Technical Report (type 2). This paper examines the rational behind the proposed alternative sampling plans. The protection provided by the current verification and audit sampling plans is first examined. Then methods for identifying equivalent plans are highlighted. Finally, methods for comparing the cost associated with the different plans are provided. This paper includes additional guidance for selecting between the original and alternative sampling plans not included in the technical report.

  19. SU-E-CAMPUS-T-05: Validation of High-Resolution 3D Patient QA for Proton Pencil Beam Scanning and IMPT by Polymer Gel Dosimetry

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Cardin, A; Avery, S; Ding, X

    2014-06-15

    Purpose: Validation of high-resolution 3D patient QA for proton pencil beam scanning and IMPT by polymer gel dosimetry. Methods: Four BANG3Pro polymer gel dosimeters (manufactured by MGS Research Inc, Madison, CT) were used for patient QA at the Robert's Proton Therapy Center (RPTC, Philadelphia, PA). All dosimeters were sealed in identical thin-wall Pyrex glass spheres. Each dosimeter contained a set of markers for 3D registration purposes. The dosimeters were mounted in a consistent and reproducible manner using a custom build holder. Two proton pencil beam scanning plans were designed using Varian Eclipse™ treatment planning system: 1) A two-field intensity modulatedmore » proton therapy (IMPT) plan and 2) one single field uniform dose (SFUD) plan. The IMPT fields were evaluated as a composite plan and individual fields, the SFUD plan was delivered as a single field plan.Laser CT scanning was performed using the manufacturer's OCTOPUS-IQ axial transmission laser CT scanner using a 1 mm slice thickness. 3D registration, analysis, and OD/cm to absorbed dose calibrations were perfomed using DICOM RT-Dose and CT files, and software developed by the manufacturer. 3D delta index, a metric equivalent to the gamma tool, was used for dose comparison. Results: Very good agreement with single IMPT fields and with SFUD was obtained. Composite IMPT fields had a less satisfactory agreement. The single fields had 3D delta index passing rates (3% dose difference, 3 mm DTA) of 98.98% and 94.91%. The composite 3D delta index passing rate was 80.80%. The SFUD passing rate was 93.77%. Required shifts of the dose distributions were less than 4 mm. Conclusion: A formulation of the BANG3Pro polymer gel dosimeter, suitable for 3D QA of proton patient plans is established and validated. Likewise, the mailed QA analysis service provided by the manufacturer is a practical option when required resources are unavailable. We fully disclose that the subject of this research regards a production of MGS Research, Inc.« less

  20. A computational method for estimating the dosimetric effect of intra-fraction motion on step-and-shoot IMRT and compensator plans

    NASA Astrophysics Data System (ADS)

    Waghorn, Ben J.; Shah, Amish P.; Ngwa, Wilfred; Meeks, Sanford L.; Moore, Joseph A.; Siebers, Jeffrey V.; Langen, Katja M.

    2010-07-01

    Intra-fraction organ motion during intensity-modulated radiation therapy (IMRT) treatment can cause differences between the planned and the delivered dose distribution. To investigate the extent of these dosimetric changes, a computational model was developed and validated. The computational method allows for calculation of the rigid motion perturbed three-dimensional dose distribution in the CT volume and therefore a dose volume histogram-based assessment of the dosimetric impact of intra-fraction motion on a rigidly moving body. The method was developed and validated for both step-and-shoot IMRT and solid compensator IMRT treatment plans. For each segment (or beam), fluence maps were exported from the treatment planning system. Fluence maps were shifted according to the target position deduced from a motion track. These shifted, motion-encoded fluence maps were then re-imported into the treatment planning system and were used to calculate the motion-encoded dose distribution. To validate the accuracy of the motion-encoded dose distribution the treatment plan was delivered to a moving cylindrical phantom using a programmed four-dimensional motion phantom. Extended dose response (EDR-2) film was used to measure a planar dose distribution for comparison with the calculated motion-encoded distribution using a gamma index analysis (3% dose difference, 3 mm distance-to-agreement). A series of motion tracks incorporating both inter-beam step-function shifts and continuous sinusoidal motion were tested. The method was shown to accurately predict the film's dose distribution for all of the tested motion tracks, both for the step-and-shoot IMRT and compensator plans. The average gamma analysis pass rate for the measured dose distribution with respect to the calculated motion-encoded distribution was 98.3 ± 0.7%. For static delivery the average film-to-calculation pass rate was 98.7 ± 0.2%. In summary, a computational technique has been developed to calculate the dosimetric effect of intra-fraction motion. This technique has the potential to evaluate a given plan's sensitivity to anticipated organ motion. With knowledge of the organ's motion it can also be used as a tool to assess the impact of measured intra-fraction motion after dose delivery.

  1. MIDURA (Minefield Detection Using Reconnaissance Assets) 1982-1983 Experimental Test Plan.

    DTIC Science & Technology

    1982-04-01

    3.2.4.2 Subjection Validation at the Salem ONG 27 3.2.4.3 Objective Validity at Fort Huachuca 28 4. TEST FLIGHTS AT ARRAYS IIa, lib, Ilia AND IIIb...subjective validation at the Salem ONG; (3) objective validation at Fort Huachuca. 3.2.4.1 Subjective Image Interpretation at ERIM The initial phase...The ERIM II’s will provide for each image estimate of PD’ Pc and PFA on a 0.00 to 1.00 scale. P is defined as the subjective probability estimate that

  2. Airborne Observations and Satellite Validation: INTEX-A Experience and INTEX-B Plans

    NASA Technical Reports Server (NTRS)

    Crawford, James H.; Singh, Hanwant B.; Brune, William H.; Jacob, Daniel J.

    2005-01-01

    Intercontinental Chemical Transport Experiment (INTEX; http://cloudl.arc.nasa.gov) is an ongoing two-phase integrated atmospheric field experiment being performed over North America (NA). Its first phase (INTEX-A) was performed in the summer of 2004 and the second phase (INTEX-B) is planned for the early spring of 2006. The main goal of INTEX-NA is to understand the transport and transformation of gases and aerosols on transcontinental/intercontinental scales and to assess their impact on air quality and climate. Central to achieving this goal is the need to relate space-based observations with those from airborne and surface platforms. During INTEX-A, NASA s DC-8 was joined by some dozen other aircraft from a large number of European and North American partners to focus on the outflow of pollution from NA to the Atlantic. Several instances of Asian pollution over NA were also encountered. INTEX-A flight planning extensively relied on satellite observations and in turn Satellite validation (Terra, Aqua, and Envisat) was given high priority. Over 20 validation profiles were successfully carried out. DC-8 sampling of smoke from Alaskan fires and formaldehyde over forested regions, and simultaneous satellite observations of these provided excellent opportunities for the interplay of these platforms. The planning for INTEX-5 is currently underway, and a vast majority of "standard" and "research" products to be retrieved from Aura instruments will be measured during INTEX-B throughout the troposphere. INTEX-B will focus on the inflow of pollution from Asia to North America and validation of satellite observations with emphasis on Aura. Several national and international partners are expected to coordinate activities with INTEX-B, and we expect its scope to expand in the coming months. An important new development involves partnership with an NSF-sponsored campaign called MIRAGE (Megacity Impacts on Regional and Global Environments- Mexico City Pollution Outflow Field Campaign; http://mirage- mex.acd.ucar.edu/index.html). This partnership will utilize both the NASA-DC-8 mad NCAR C-130 aircrafts and greatly expand the temporal and spatial coverage of these experiments. We will briefly describe our INTEX-A experience and discuss plans for INTEX-B activities especially as they relate to validation and interpretation of Aura observations.

  3. Hypersonic Experimental and Computational Capability, Improvement and Validation. Volume 2

    NASA Technical Reports Server (NTRS)

    Muylaert, Jean (Editor); Kumar, Ajay (Editor); Dujarric, Christian (Editor)

    1998-01-01

    The results of the phase 2 effort conducted under AGARD Working Group 18 on Hypersonic Experimental and Computational Capability, Improvement and Validation are presented in this report. The first volume, published in May 1996, mainly focused on the design methodology, plans and some initial results of experiments that had been conducted to serve as validation benchmarks. The current volume presents the detailed experimental and computational data base developed during this effort.

  4. Experimental validation of the van Herk margin formula for lung radiation therapy

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Ecclestone, Gillian; Heath, Emily; Bissonnette, Jean-Pierre

    2013-11-15

    Purpose: To validate the van Herk margin formula for lung radiation therapy using realistic dose calculation algorithms and respiratory motion modeling. The robustness of the margin formula against variations in lesion size, peak-to-peak motion amplitude, tissue density, treatment technique, and plan conformity was assessed, along with the margin formula assumption of a homogeneous dose distribution with perfect plan conformity.Methods: 3DCRT and IMRT lung treatment plans were generated within the ORBIT treatment planning platform (RaySearch Laboratories, Sweden) on 4DCT datasets of virtual phantoms. Random and systematic respiratory motion induced errors were simulated using deformable registration and dose accumulation tools available withinmore » ORBIT for simulated cases of varying lesion sizes, peak-to-peak motion amplitudes, tissue densities, and plan conformities. A detailed comparison between the margin formula dose profile model, the planned dose profiles, and penumbra widths was also conducted to test the assumptions of the margin formula. Finally, a correction to account for imperfect plan conformity was tested as well as a novel application of the margin formula that accounts for the patient-specific motion trajectory.Results: The van Herk margin formula ensured full clinical target volume coverage for all 3DCRT and IMRT plans of all conformities with the exception of small lesions in soft tissue. No dosimetric trends with respect to plan technique or lesion size were observed for the systematic and random error simulations. However, accumulated plans showed that plan conformity decreased with increasing tumor motion amplitude. When comparing dose profiles assumed in the margin formula model to the treatment plans, discrepancies in the low dose regions were observed for the random and systematic error simulations. However, the margin formula respected, in all experiments, the 95% dose coverage required for planning target volume (PTV) margin derivation, as defined by the ICRU; thus, suitable PTV margins were estimated. The penumbra widths calculated in lung tissue for each plan were found to be very similar to the 6.4 mm value assumed by the margin formula model. The plan conformity correction yielded inconsistent results which were largely affected by image and dose grid resolution while the trajectory modified PTV plans yielded a dosimetric benefit over the standard internal target volumes approach with up to a 5% decrease in the V20 value.Conclusions: The margin formula showed to be robust against variations in tumor size and motion, treatment technique, plan conformity, as well as low tissue density. This was validated by maintaining coverage of all of the derived PTVs by 95% dose level, as required by the formal definition of the PTV. However, the assumption of perfect plan conformity in the margin formula derivation yields conservative margin estimation. Future modifications to the margin formula will require a correction for plan conformity. Plan conformity can also be improved by using the proposed trajectory modified PTV planning approach. This proves especially beneficial for tumors with a large anterior–posterior component of respiratory motion.« less

  5. In-Space Structural Validation Plan for a Stretched-Lens Solar Array Flight Experiment

    NASA Technical Reports Server (NTRS)

    Pappa, Richard S.; Woods-Vedeler, Jessica A.; Jones, Thomas W.

    2001-01-01

    This paper summarizes in-space structural validation plans for a proposed Space Shuttle-based flight experiment. The test article is an innovative, lightweight solar array concept that uses pop-up, refractive stretched-lens concentrators to achieve a power/mass density of at least 175 W/kg, which is more than three times greater than current capabilities. The flight experiment will validate this new technology to retire the risk associated with its first use in space. The experiment includes structural diagnostic instrumentation to measure the deployment dynamics, static shape, and modes of vibration of the 8-meter-long solar array and several of its lenses. These data will be obtained by photogrammetry using the Shuttle payload-bay video cameras and miniature video cameras on the array. Six accelerometers are also included in the experiment to measure base excitations and small-amplitude tip motions.

  6. SU-F-T-447: The Impact of Treatment Planning Methods On RapidPlan Modeling for Rectum Cancer

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Lu, S; Peng, J; Li, K

    2016-06-15

    Purpose: To investigate the dose volume histogram (DVH) prediction varieties based on intensity modulate radiotherapy (IMRT) plan or volume arc modulate radiotherapy (VMAT) plan models on the RapidPlan. Methods: Two DVH prediction models were generated in this study, including an IMRT model trained from 83 IMRT rectum plans and a VMAT model trained from 60 VMAT rectum plans. In the internal validation, 20 plans from each training database were selected to verify the clinical feasibility of the model. Then, 10 IMRT plans (PIMRT-by-IMRT-model) generated from IMRT model and 10 IMRT plans generated from VMAT model (PIMRT-by-VMAT-model) were compared on themore » dose to organs at risk (OAR), which included bladder, left and right femoral heads. The similar comparison was also performed on the VMAT plans generated from IMRT model (PVMAT-by-IMRT-model) and VMAT plans generated from VMAT (PVMAT-by-VMAT-model) model. Results: For the internal validation, all plans from IMRT or VMAT model shows significantly improvement on OAR sparing compared with the corresponded clinical ones. Compared to the PIMRT-by-VMAT-model, the PIMRT-by-IMRT-model has a reduction of 6.90±3.87%(p<0.001) on V40 6.63±3.62%(p<0.001) on V45 and 4.74±2.26%(p<0.001) on V50 in bladder; and a mean dose reduction of 2.12±1.75Gy(p=0.004) and 2.84±1.53Gy(p<0.001) in right and left femoral head, respectively. There was no significant difference on OAR sparing between PVMAT-by-IMRT-model and PVMAT-by-VMAT-model. Conclusion: The IMRT model for the rectal cancer in the RapidPlan can be applied to for VMAT planning. However, the VMAT model is not suggested to use in the IMRT planning. Cautions should be taken that the planning model based on some technique may not feasible to other planning techniques.« less

  7. Data Validation Package August 2015 Groundwater Sampling at the Grand Junction, Colorado, Disposal Site October 2015

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Frazier, William; Baur, Gary

    2015-11-03

    The 1998 Interim Long-Term Surveillance Plan for the Cheney Disposal Site Near Grand Junction, Colorado, requires annual monitoring to assess the performance of the disposal cell. Monitoring wells 0731, 0732 and 0733 were sampled as specified in the plan. Sampling and analyses were conducted in accordance with Sampling and Analysis Plan for the U.S. Department of Energy Office of Legacy Management Sites.

  8. A Study to Determine the Validity of the Nursing Admission Assessment (DA Form 3888/3888-1) as a Mechanism for Identifying the Presence of One or More Universal Indicators of the Need for Discharge Planning

    DTIC Science & Technology

    1987-08-01

    in the hope that Army hospitals could begin to develop discharge planning programs in advance of the publica- tion of the proposed JCAH standard (see... Ostomy patients 24. Coronary bypass patients 11 BAMC Memo 40-25 94 APPENDIX C Discharge Planning Screen for Drug-Nutrient Interactions JCAH requires

  9. A Genetically Engineered Mouse Model of Neuroblastoma Driven by Mutated ALK and MYCN

    DTIC Science & Technology

    2015-09-01

    Through publications in scientific journals (see Journal publications). What do you plan to do during the next reporting period to accomplish the goals...We plan to elucidate the mechanism of action of the synergy between ALK and CDK inhibitors, validate CDK7 inhibition as a tractable therapeutic...delays and actions or plans to resolve them Nothing to Report Changes that had a significant impact on expenditures Nothing to Report Significant

  10. Utilization of the supports intensity scale with psychiatric populations: psychometric properties and utility for service delivery planning.

    PubMed

    Jenaro, Cristina; Cruz, Maribel; Perez, María Del Carmen; Flores, Noelia E; Vega, Vanessa

    2011-10-01

    In agreement with the new paradigm of supports, this study examines the adequacy and psychometric properties of the Supports Intensity Scale (SIS) in a sample of 182 participants with severe mental illness (mean Global Assessment of Functioning [GAF] score = 60.2). The measure focuses on identifying the profile and intensities of support needs and on the planning and service delivery rather than on weaknesses and limitations. Internal consistency indexes ranged from .83 to .97; interrater reliability indexes ranged from .67 to .98. Intercorrelations among SIS subscales supported its construct validity. SIS scores correlated to GAF scores and length of disease. Discriminant analysis correctly classified 60.9% of participants. Therefore, the SIS demonstrated adequate reliability and validity, and it can be used by nursing professionals to plan for required supports in this population. Copyright © 2011 Elsevier Inc. All rights reserved.

  11. Project W-314 specific test and evaluation plan for AZ tank farm upgrades

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Hays, W.H.

    1998-08-12

    The purpose of this Specific Test and Evaluation Plan (STEP) is to provide a detailed written plan for the systematic testing of modifications made by the addition of the SN-631 transfer line from the AZ-O1A pit to the AZ-02A pit by the W-314 Project. The STEP develops the outline for test procedures that verify the system`s performance to the established Project design criteria. The STEP is a lower tier document based on the W-314 Test and Evaluation P1 an (TEP). Testing includes Validations and Verifications (e.g., Commercial Grade Item Dedication activities, etc), Factory Tests and Inspections (FTIs), installation tests andmore » inspections, Construction Tests and Inspections (CTIs), Acceptance Test Procedures (ATPs), Pre-Operational Test Procedures (POTPs), and Operational Test Procedures (OTPs). The STEP will be utilized in conjunction with the TEP for verification and validation.« less

  12. RELAP-7 Software Verification and Validation Plan

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Smith, Curtis L.; Choi, Yong-Joon; Zou, Ling

    This INL plan comprehensively describes the software for RELAP-7 and documents the software, interface, and software design requirements for the application. The plan also describes the testing-based software verification and validation (SV&V) process—a set of specially designed software models used to test RELAP-7. The RELAP-7 (Reactor Excursion and Leak Analysis Program) code is a nuclear reactor system safety analysis code being developed at Idaho National Laboratory (INL). The code is based on the INL’s modern scientific software development framework – MOOSE (Multi-Physics Object-Oriented Simulation Environment). The overall design goal of RELAP-7 is to take advantage of the previous thirty yearsmore » of advancements in computer architecture, software design, numerical integration methods, and physical models. The end result will be a reactor systems analysis capability that retains and improves upon RELAP5’s capability and extends the analysis capability for all reactor system simulation scenarios.« less

  13. A Principal Components Analysis and Validation of the Coping with the College Environment Scale (CWCES)

    ERIC Educational Resources Information Center

    Ackermann, Margot Elise; Morrow, Jennifer Ann

    2008-01-01

    The present study describes the development and initial validation of the Coping with the College Environment Scale (CWCES). Participants included 433 college students who took an online survey. Principal Components Analysis (PCA) revealed six coping strategies: planning and self-management, seeking support from institutional resources, escaping…

  14. 21 CFR 120.11 - Verification and validation.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... analysis. Whenever a juice processor has no HACCP plan because a hazard analysis has revealed no food... analysis whenever there are any changes in the process that could reasonably affect whether a food hazard... 21 Food and Drugs 2 2013-04-01 2013-04-01 false Verification and validation. 120.11 Section 120.11...

  15. 21 CFR 120.11 - Verification and validation.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... analysis. Whenever a juice processor has no HACCP plan because a hazard analysis has revealed no food... analysis whenever there are any changes in the process that could reasonably affect whether a food hazard... 21 Food and Drugs 2 2012-04-01 2012-04-01 false Verification and validation. 120.11 Section 120.11...

  16. 21 CFR 120.11 - Verification and validation.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... analysis. Whenever a juice processor has no HACCP plan because a hazard analysis has revealed no food... analysis whenever there are any changes in the process that could reasonably affect whether a food hazard... 21 Food and Drugs 2 2011-04-01 2011-04-01 false Verification and validation. 120.11 Section 120.11...

  17. 21 CFR 120.11 - Verification and validation.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... analysis. Whenever a juice processor has no HACCP plan because a hazard analysis has revealed no food... analysis whenever there are any changes in the process that could reasonably affect whether a food hazard... 21 Food and Drugs 2 2014-04-01 2014-04-01 false Verification and validation. 120.11 Section 120.11...

  18. 21 CFR 120.11 - Verification and validation.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... analysis. Whenever a juice processor has no HACCP plan because a hazard analysis has revealed no food... analysis whenever there are any changes in the process that could reasonably affect whether a food hazard... 21 Food and Drugs 2 2010-04-01 2010-04-01 false Verification and validation. 120.11 Section 120.11...

  19. Validation of the Informal Decoding Inventory

    ERIC Educational Resources Information Center

    McKenna, Michael C.; Walpole, Sharon; Jang, Bong Gee

    2017-01-01

    This study investigated the reliability and validity of Part 1 of the Informal Decoding Inventory (IDI), a free diagnostic assessment used to plan Tier 2 intervention for first graders with decoding deficits. Part 1 addresses single-syllable words and consists of five subtests that progress in difficulty and that contain real word and pseudoword…

  20. 43 CFR 3140.2-3 - Application requirements.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... Conversion of Existing Oil and Gas Leases and Valid Claims Based on Mineral Locations § 3140.2-3 Application... existing oil and gas lease or valid claim or for an area of proposed unit operation. (d) The plan of operations shall identify by lease number all Federal oil and gas leases proposed for conversion and identify...

  1. 43 CFR 3140.2-3 - Application requirements.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... Conversion of Existing Oil and Gas Leases and Valid Claims Based on Mineral Locations § 3140.2-3 Application... existing oil and gas lease or valid claim or for an area of proposed unit operation. (d) The plan of operations shall identify by lease number all Federal oil and gas leases proposed for conversion and identify...

  2. 43 CFR 3140.2-3 - Application requirements.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... Conversion of Existing Oil and Gas Leases and Valid Claims Based on Mineral Locations § 3140.2-3 Application... existing oil and gas lease or valid claim or for an area of proposed unit operation. (d) The plan of operations shall identify by lease number all Federal oil and gas leases proposed for conversion and identify...

  3. 43 CFR 3140.2-3 - Application requirements.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... Conversion of Existing Oil and Gas Leases and Valid Claims Based on Mineral Locations § 3140.2-3 Application... existing oil and gas lease or valid claim or for an area of proposed unit operation. (d) The plan of operations shall identify by lease number all Federal oil and gas leases proposed for conversion and identify...

  4. Reliability, Validity and Utility of a Multiple Intelligences Assessment for Career Planning.

    ERIC Educational Resources Information Center

    Shearer, C. Branton

    "The Multiple Intelligences Developmental Assessment Scales" (MIDAS) is a self- (or other-) completed instrument which is based upon the theory of multiple intelligences. The validity, reliability, and utility data regarding the MIDAS are reported here. The measure consists of 7 main scales and 24 subscales which summarize a person's intellectual…

  5. EOS-Aura's Ozone Monitoring Instrument (OMI): Validation Requirements

    NASA Technical Reports Server (NTRS)

    Brinksma, E. J.; McPeters, R.; deHaan, J. F.; Levelt, P. F.; Hilsenrath, E.; Bhartia, P. K.

    2003-01-01

    OMI is an advanced hyperspectral instrument that measures backscattered radiation in the UV and visible. It will be flown as part of the EOS Aura mission and provide data on atmospheric chemistry that is highly synergistic with other Aura instruments HIRDLS, MLS, and TES. OMI is designed to measure total ozone, aerosols, cloud information, and UV irradiances, continuing the TOMS series of global mapped products but with higher spatial resolution. In addition its hyperspectral capability enables measurements of trace gases such as SO2, NO2, HCHO, BrO, and OClO. A plan for validation of the various OM1 products is now being formulated. Validation of the total column and UVB products will rely heavily on existing networks of instruments, like NDSC. NASA and its European partners are planning aircraft missions for the validation of Aura instruments. New instruments and techniques (DOAS systems for example) will need to be developed, both ground and aircraft based. Lidar systems are needed for validation of the vertical distributions of ozone, aerosols, NO2 and possibly SO2. The validation emphasis will be on the retrieval of these products under polluted conditions. This is challenging because they often depend on the tropospheric profiles of the product in question, and because of large spatial variations in the troposphere. Most existing ground stations are located in, and equipped for, pristine environments. This is also true for almost all NDSC stations. OMI validation will need ground based sites in polluted environments and specially developed instruments, complementing the existing instrumentation.

  6. Validation of Fully Automated VMAT Plan Generation for Library-Based Plan-of-the-Day Cervical Cancer Radiotherapy

    PubMed Central

    Breedveld, Sebastiaan; Voet, Peter W. J.; Heijkoop, Sabrina T.; Mens, Jan-Willem M.; Hoogeman, Mischa S.; Heijmen, Ben J. M.

    2016-01-01

    Purpose To develop and validate fully automated generation of VMAT plan-libraries for plan-of-the-day adaptive radiotherapy in locally-advanced cervical cancer. Material and Methods Our framework for fully automated treatment plan generation (Erasmus-iCycle) was adapted to create dual-arc VMAT treatment plan libraries for cervical cancer patients. For each of 34 patients, automatically generated VMAT plans (autoVMAT) were compared to manually generated, clinically delivered 9-beam IMRT plans (CLINICAL), and to dual-arc VMAT plans generated manually by an expert planner (manVMAT). Furthermore, all plans were benchmarked against 20-beam equi-angular IMRT plans (autoIMRT). For all plans, a PTV coverage of 99.5% by at least 95% of the prescribed dose (46 Gy) had the highest planning priority, followed by minimization of V45Gy for small bowel (SB). Other OARs considered were bladder, rectum, and sigmoid. Results All plans had a highly similar PTV coverage, within the clinical constraints (above). After plan normalizations for exactly equal median PTV doses in corresponding plans, all evaluated OAR parameters in autoVMAT plans were on average lower than in the CLINICAL plans with an average reduction in SB V45Gy of 34.6% (p<0.001). For 41/44 autoVMAT plans, SB V45Gy was lower than for manVMAT (p<0.001, average reduction 30.3%), while SB V15Gy increased by 2.3% (p = 0.011). AutoIMRT reduced SB V45Gy by another 2.7% compared to autoVMAT, while also resulting in a 9.0% reduction in SB V15Gy (p<0.001), but with a prolonged delivery time. Differences between manVMAT and autoVMAT in bladder, rectal and sigmoid doses were ≤ 1%. Improvements in SB dose delivery with autoVMAT instead of manVMAT were higher for empty bladder PTVs compared to full bladder PTVs, due to differences in concavity of the PTVs. Conclusions Quality of automatically generated VMAT plans was superior to manually generated plans. Automatic VMAT plan generation for cervical cancer has been implemented in our clinical routine. Due to the achieved workload reduction, extension of plan libraries has become feasible. PMID:28033342

  7. Teachers and Technology: Development of an Extended Theory of Planned Behavior

    ERIC Educational Resources Information Center

    Teo, Timothy; Zhou, Mingming; Noyes, Jan

    2016-01-01

    This study tests the validity of an extended theory of planned behaviour (TPB) to explain teachers' intention to use technology for teaching and learning. Five hundred and ninety two participants completed a survey questionnaire measuring their responses to eight constructs which form an extended TPB. Using structural equation modelling, the…

  8. Process for Refining and Validating a Finite Element Model of an Experimental High-Altitude, Long-Endurance (HALE) Aircraft

    DTIC Science & Technology

    2011-06-01

    7 Figure 4. Helios flying near the Hawaiian islands of Niihau and Lehua [15] ................... 8 Figure 5. Plan view of ERAST Program aircraft...Figure 4. Helios flying near the Hawaiian islands of Niihau and Lehua [15] 9 Figure 5. Plan view of ERAST Program aircraft

  9. Rewarding Teachers: Issues and Incentives.

    ERIC Educational Resources Information Center

    Newcombe, Ellen

    This paper discusses some of the issues behind the current debate on merit pay for teachers. A brief history is presented of performance-based compensation systems. The difficulties in arriving at a consensus on a valid definition of merit pay are pointed out, and examples are presented of various merit plans, such as master teaching plans, career…

  10. Behavioral Intervention Planning: Increasing Appropriate Behavior of a Socially Withdrawn Student

    ERIC Educational Resources Information Center

    Christensen, Lynnette; Young, K. Richard; Marchant, Michelle

    2007-01-01

    This study examined the effects of an assessment-based intervention plan on the appropriate classroom behavior of a socially withdrawn, Hispanic, learning disabled, third grade student. The study focused on (1) the effects of peer mediation as part of a behavioral intervention package of empirically validated components, (2) the effects of…

  11. Coaxial cable sensors and sensing instrument for crack detection in bridge structures--phase I : field qualification/validation planning : final report.

    DOT National Transportation Integrated Search

    2009-11-06

    The objectives of this study are to pre-test analyze a decommissioned RC bridge that is selected in consultation : with New York State Department of Transportation (NYSDOT), and design and plan the field tests of the bridge : for the performance qual...

  12. Data Validation Package - July 2016 Groundwater Sampling at the Gunnison, Colorado, Disposal Site

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Linard, Joshua; Campbell, Sam

    Groundwater sampling at the Gunnison, Colorado, Disposal Site is conducted every 5 years to monitor disposal cell performance. During this event, samples were collected from eight monitoring wells as specified in the 1997 Long-Term Surveillance Plan for the Gunnison, Colorado, Disposal Site. Sampling and analyses were conducted as specified in the Sampling and Analysis Plan for US Department of Energy Office of Legacy Management Sites (LMS/PRO/S04351, continually updated, http://energy.gov/lm/downloads/sampling-and­ analysis-plan-us-department-energy-office-legacy-management-sites). Planned monitoring locations are shown in Attachment 1, Sampling and Analysis Work Order. A duplicate sample was collected from location 0723. Water levels were measured at all monitoring wells thatmore » were sampled and seven additional wells. The analytical data and associated qualifiers can be viewed in environmental database reports and are also available for viewing with dynamic mapping via the GEMS (Geospatial Environmental Mapping System) website at http://gems.lm.doe.gov/#. No issues were identified during the data validation process that require additional action or follow-up.« less

  13. [Satisfaction according to health care insurance systems in an emergency department].

    PubMed

    Dávila, F A; Herrera, J S; Yasnó, D A; Forero, L C; Alvarado, M V

    Health satisfaction is a fundamental measure of the quality of health services. This study aims to validate and analyse the results of a quality of care questionnaire to assess the level of satisfaction of patients attended in the emergency department of a high complexity hospital. Observational, cross-sectional study, with a questionnaire designed to assess the quality of service and satisfaction at the end of care in the emergency department. Descriptive statistics of scale were established and presented, as well as determining the construct validity, overall reliability, internal and concurrent validity of an overall against a uni-dimensional scale. A total of 5,961 records were reviewed, most of them (77.3%) reported by patients in the Mandatory Health Plan. High levels of satisfaction overall and by subgroups were found. There were no significant differences between subgroups, with 86.8 for those with Pre-paid Medical Care Plan and 84.4 for mandatory health plan. Cronbach's alpha for the questionnaire was 0.90. The questionnaire proved to be reliable and valid in determining the quality and satisfaction with care. The results showed high levels of satisfaction overall and in the domains. A low consistency between the results of the multidimensional and unidimensional satisfaction scales suggests that there were aspects of satisfaction not investigated on the multidimensional scale. Ecologically-designed before and after studies are required to evaluate the effectiveness of interventions in satisfaction. Copyright © 2016 SECA. Publicado por Elsevier España, S.L.U. All rights reserved.

  14. Model Validation Against The Modelers’ Data Archive

    DTIC Science & Technology

    2014-08-01

    completion of the planned Jack Rabbit 2 field trials. The relevant task for the effort addressed here is Task 4 of the current Interagency Agreement, as...readily simulates the Prairie Grass sulfur dioxide plumes. Also, Jack Rabbit II field trials are set to be completed during FY16. Once these data are...available, they will also be used to validate the combined models. This validation may prove to be more useful, as the Jack Rabbit II will release

  15. Understanding pregnancy planning in a low-income country setting: validation of the London measure of unplanned pregnancy in Malawi.

    PubMed

    Hall, Jennifer; Barrett, Geraldine; Mbwana, Nicholas; Copas, Andrew; Malata, Address; Stephenson, Judith

    2013-11-05

    The London Measure of Unplanned Pregnancy (LMUP) is a new and psychometrically valid measure of pregnancy intention that was developed in the United Kingdom. An improved understanding of pregnancy intention in low-income countries, where unintended pregnancies are common and maternal and neonatal deaths are high, is necessary to inform policies to address the unmet need for family planning. To this end this research aimed to validate the LMUP for use in the Chichewa language in Malawi. Three Chichewa speakers translated the LMUP and one translation was agreed which was back-translated and pre-tested on five pregnant women using cognitive interviews. The measure was field tested with pregnant women who were recruited at antenatal clinics and data were analysed using classical test theory and hypothesis testing. 125 women aged 15-43 (median 23), with parities of 1-8 (median 2) completed the Chichewa LMUP. There were no missing data. The full range of LMUP scores was captured. In terms of reliability, the scale was internally consistent (Cronbach's alpha = 0.78) and test-retest data from 70 women showed good stability (weighted Kappa 0.80). In terms of validity, hypothesis testing confirmed that unmarried women (p = 0.003), women who had four or more children alive (p = 0.0051) and women who were below 20 or over 29 (p = 0.0115) were all more likely to have unintended pregnancies. Principal component analysis showed that five of the six items loaded onto one factor, with a further item borderline. A sensitivity analysis to assess the effect of the removal of the weakest item of the scale showed slightly improved performance but as the LMUP was not significantly adversely affected by its inclusion we recommend retaining the six-item score. The Chichewa LMUP is a valid and reliable measure of pregnancy intention in Malawi and can now be used in research and/or surveillance. This is the first validation of this tool in a low-income country, helping to demonstrate that the concept of pregnancy planning is applicable in such a setting. Use of the Chichewa LMUP can enhance our understanding of pregnancy intention in Malawi, giving insight into the family planning services that are required to better meet women's needs and save lives.

  16. Automated Planning and Scheduling for Orbital Express (151)

    NASA Technical Reports Server (NTRS)

    Knight, Russell

    2008-01-01

    The challenging timeline for DARPA's Orbital Express mission demanded a flexible, responsive, and (above all) safe approach to mission planning. Because the mission was a technology demonstration, pertinent planning information was learned during actual mission execution. This information led to amendments to procedures, which led to changes in the mission plan. In general, we used the ASPEN planner scheduler to generate and validate the mission plans. We enhanced ASPEN to enable it to reason about uncertainty. We also developed a model generator that would read the text of a procedure and translate it into an ASPEN model. These technologies had a significant impact on the success of the Orbital Express mission.

  17. Application of Large-Scale Aptamer-Based Proteomic Profiling to Planned Myocardial Infarctions.

    PubMed

    Jacob, Jaison; Ngo, Debby; Finkel, Nancy; Pitts, Rebecca; Gleim, Scott; Benson, Mark D; Keyes, Michelle J; Farrell, Laurie A; Morgan, Thomas; Jennings, Lori L; Gerszten, Robert E

    2018-03-20

    Emerging proteomic technologies using novel affinity-based reagents allow for efficient multiplexing with high-sample throughput. To identify early biomarkers of myocardial injury, we recently applied an aptamer-based proteomic profiling platform that measures 1129 proteins to samples from patients undergoing septal alcohol ablation for hypertrophic cardiomyopathy, a human model of planned myocardial injury. Here, we examined the scalability of this approach using a markedly expanded platform to study a far broader range of human proteins in the context of myocardial injury. We applied a highly multiplexed, expanded proteomic technique that uses single-stranded DNA aptamers to assay 4783 human proteins (4137 distinct human gene targets) to derivation and validation cohorts of planned myocardial injury, individuals with spontaneous myocardial infarction, and at-risk controls. We found 376 target proteins that significantly changed in the blood after planned myocardial injury in a derivation cohort (n=20; P <1.05E-05, 1-way repeated measures analysis of variance, Bonferroni threshold). Two hundred forty-seven of these proteins were validated in an independent planned myocardial injury cohort (n=15; P <1.33E-04, 1-way repeated measures analysis of variance); >90% were directionally consistent and reached nominal significance in the validation cohort. Among the validated proteins that were increased within 1 hour after planned myocardial injury, 29 were also elevated in patients with spontaneous myocardial infarction (n=63; P <6.17E-04). Many of the novel markers identified in our study are intracellular proteins not previously identified in the peripheral circulation or have functional roles relevant to myocardial injury. For example, the cardiac LIM protein, cysteine- and glycine-rich protein 3, is thought to mediate cardiac mechanotransduction and stress responses, whereas the mitochondrial ATP synthase F 0 subunit component is a vasoactive peptide on its release from cells. Last, we performed aptamer-affinity enrichment coupled with mass spectrometry to technically verify aptamer specificity for a subset of the new biomarkers. Our results demonstrate the feasibility of large-scale aptamer multiplexing at a level that has not previously been reported and with sample throughput that greatly exceeds other existing proteomic methods. The expanded aptamer-based proteomic platform provides a unique opportunity for biomarker and pathway discovery after myocardial injury. © 2017 American Heart Association, Inc.

  18. Independent Monte-Carlo dose calculation for MLC based CyberKnife radiotherapy

    NASA Astrophysics Data System (ADS)

    Mackeprang, P.-H.; Vuong, D.; Volken, W.; Henzen, D.; Schmidhalter, D.; Malthaner, M.; Mueller, S.; Frei, D.; Stampanoni, M. F. M.; Dal Pra, A.; Aebersold, D. M.; Fix, M. K.; Manser, P.

    2018-01-01

    This work aims to develop, implement and validate a Monte Carlo (MC)-based independent dose calculation (IDC) framework to perform patient-specific quality assurance (QA) for multi-leaf collimator (MLC)-based CyberKnife® (Accuray Inc., Sunnyvale, CA) treatment plans. The IDC framework uses an XML-format treatment plan as exported from the treatment planning system (TPS) and DICOM format patient CT data, an MC beam model using phase spaces, CyberKnife MLC beam modifier transport using the EGS++ class library, a beam sampling and coordinate transformation engine and dose scoring using DOSXYZnrc. The framework is validated against dose profiles and depth dose curves of single beams with varying field sizes in a water tank in units of cGy/Monitor Unit and against a 2D dose distribution of a full prostate treatment plan measured with Gafchromic EBT3 (Ashland Advanced Materials, Bridgewater, NJ) film in a homogeneous water-equivalent slab phantom. The film measurement is compared to IDC results by gamma analysis using 2% (global)/2 mm criteria. Further, the dose distribution of the clinical treatment plan in the patient CT is compared to TPS calculation by gamma analysis using the same criteria. Dose profiles from IDC calculation in a homogeneous water phantom agree within 2.3% of the global max dose or 1 mm distance to agreement to measurements for all except the smallest field size. Comparing the film measurement to calculated dose, 99.9% of all voxels pass gamma analysis, comparing dose calculated by the IDC framework to TPS calculated dose for the clinical prostate plan shows 99.0% passing rate. IDC calculated dose is found to be up to 5.6% lower than dose calculated by the TPS in this case near metal fiducial markers. An MC-based modular IDC framework was successfully developed, implemented and validated against measurements and is now available to perform patient-specific QA by IDC.

  19. SU-F-T-617: Remotely Pre-Planned Stereotactic Ablative Radiation Therapy: Validation of Treatment Plan Quality

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Juang, T; Bush, K; Loo, B

    Purpose: We propose a workflow to improve access to stereotactic ablative radiation therapy (SABR) for rural patients. When implemented, a separate trip to the central facility for simulation can be eliminated. Two elements are required: (1) Fabrication of custom immobilization devices to match positioning on prior diagnostic CT (dxCT). (2) Remote radiation pre-planning on dxCT, with transfer of contours/plan to simulation CT (simCT) and initiation of treatment same-day or next day. In this retrospective study, we validated part 2 of the workflow using patients already treated with SABR for upper lobe lung tumors. Methods: Target/normal structures were contoured on dxCT;more » a plan was created and approved by the physician. Structures were transferred to simCT using deformable image registration and the plan was re-optimized on simCT. Plan quality was evaluated through comparison to gold-standard structures contoured on simCT and a gold-standard plan based on these structures. Workflow-generated plan quality in this study represents a worst-case scenario as these patients were not treated using custom immobilization to match dxCT position as would be done when the workflow is implemented clinically. Results: 5/6 plans created through the pre-planning workflow were clinically acceptable. For all six plans, the gold-standard GTV received full prescription dose, along with median PTV V95%=95.2% and median PTV D95%=95.4%. Median GTV DSC=0.80, indicating high degree of similarity between the deformed and gold-standard GTV contours despite small GTV sizes (mean=3.0cc). One outlier (DSC=0.49) resulted in inadequate PTV coverage (V95%=62.9%) in the workflow plan; in clinical practice, this mismatch between deformed/gold-standard GTV would be revised by the physician after deformable registration. For all patients, normal tissue doses were comparable to the gold-standard plan and well within constraints. Conclusion: Pre-planning SABR cases on diagnostic imaging generated clinically acceptable plans. Coupled with rapid-prototyped custom immobilization, this workflow may improve treatment access for rural patients.« less

  20. Increasing the Runtime Speed of Case-Based Plan Recognition

    DTIC Science & Technology

    2015-05-01

    number of situations that the robot might reasonably be expected to encounter. This requires ef- ficient indexing schemes to ensure that plan retrieval...collection of information if it does not display a currently valid OMB control number . 1. REPORT DATE MAY 2015 2. REPORT TYPE 3. DATES COVERED 00...00-2015 to 00-00-2015 4. TITLE AND SUBTITLE Increasing the Runtime Speed of Case-Based Plan Recognition 5a. CONTRACT NUMBER 5b. GRANT NUMBER 5c

  1. Drift-Scale Coupled Processes (DST and THC Seepage) Models

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    P. Dixon

    The purpose of this Model Report (REV02) is to document the unsaturated zone (UZ) models used to evaluate the potential effects of coupled thermal-hydrological-chemical (THC) processes on UZ flow and transport. This Model Report has been developed in accordance with the ''Technical Work Plan for: Performance Assessment Unsaturated Zone'' (Bechtel SAIC Company, LLC (BSC) 2002 [160819]). The technical work plan (TWP) describes planning information pertaining to the technical scope, content, and management of this Model Report in Section 1.12, Work Package AUZM08, ''Coupled Effects on Flow and Seepage''. The plan for validation of the models documented in this Model Reportmore » is given in Attachment I, Model Validation Plans, Section I-3-4, of the TWP. Except for variations in acceptance criteria (Section 4.2), there were no deviations from this TWP. This report was developed in accordance with AP-SIII.10Q, ''Models''. This Model Report documents the THC Seepage Model and the Drift Scale Test (DST) THC Model. The THC Seepage Model is a drift-scale process model for predicting the composition of gas and water that could enter waste emplacement drifts and the effects of mineral alteration on flow in rocks surrounding drifts. The DST THC model is a drift-scale process model relying on the same conceptual model and much of the same input data (i.e., physical, hydrological, thermodynamic, and kinetic) as the THC Seepage Model. The DST THC Model is the primary method for validating the THC Seepage Model. The DST THC Model compares predicted water and gas compositions, as well as mineral alteration patterns, with observed data from the DST. These models provide the framework to evaluate THC coupled processes at the drift scale, predict flow and transport behavior for specified thermal-loading conditions, and predict the evolution of mineral alteration and fluid chemistry around potential waste emplacement drifts. The DST THC Model is used solely for the validation of the THC Seepage Model and is not used for calibration to measured data.« less

  2. Monte Carlo modeling of HD120 multileaf collimator on Varian TrueBeam linear accelerator for verification of 6X and 6X FFF VMAT SABR treatment plans

    PubMed Central

    Gete, Ermias; Duzenli, Cheryl; Teke, Tony

    2014-01-01

    A Monte Carlo (MC) validation of the vendor‐supplied Varian TrueBeam 6 MV flattened (6X) phase‐space file and the first implementation of the Siebers‐Keall MC MLC model as applied to the HD120 MLC (for 6X flat and 6X flattening filterfree (6X FFF) beams) are described. The MC model is validated in the context of VMAT patient‐specific quality assurance. The Monte Carlo commissioning process involves: 1) validating the calculated open‐field percentage depth doses (PDDs), profiles, and output factors (OF), 2) adapting the Siebers‐Keall MLC model to match the new HD120‐MLC geometry and material composition, 3) determining the absolute dose conversion factor for the MC calculation, and 4) validating this entire linac/MLC in the context of dose calculation verification for clinical VMAT plans. MC PDDs for the 6X beams agree with the measured data to within 2.0% for field sizes ranging from 2 × 2 to 40 × 40 cm2. Measured and MC profiles show agreement in the 50% field width and the 80%‐20% penumbra region to within 1.3 mm for all square field sizes. MC OFs for the 2 to 40 cm2 square fields agree with measurement to within 1.6%. Verification of VMAT SABR lung, liver, and vertebra plans demonstrate that measured and MC ion chamber doses agree within 0.6% for the 6X beam and within 2.0% for the 6X FFF beam. A 3D gamma factor analysis demonstrates that for the 6X beam, > 99% of voxels meet the pass criteria (3%/3 mm). For the 6X FFF beam, > 94% of voxels meet this criteria. The TrueBeam accelerator delivering 6X and 6X FFF beams with the HD120 MLC can be modeled in Monte Carlo to provide an independent 3D dose calculation for clinical VMAT plans. This quality assurance tool has been used clinically to verify over 140 6X and 16 6X FFF TrueBeam treatment plans. PACS number: 87.55.K‐ PMID:24892341

  3. GOSAT-2 : Science Plan, Products, Validation, and Application

    NASA Astrophysics Data System (ADS)

    Matsunaga, T.; Morino, I.; Yoshida, Y.; Saito, M.; Hiraki, K.; Yokota, Y.; Kamei, A.; Oishi, Y.; Dupuy, E.; Murakami, K.; Ninomiya, K.; Pang, J. S.; Yokota, T.; Maksyutov, S. S.; Machida, T.; Saigusa, N.; Mukai, H.; Nakajima, M.; Imasu, R.; Nakajima, T.

    2013-12-01

    Based on the success of Greenhouse Gases Observing Satellite (GOSAT) launched in 2009, Ministry of the Environment (MOE), Japan Space Exploration Agency (JAXA), and National Institute for Environmental Studies (NIES) started the preparations for the follow-on satellite, GOSAT-2 in FY2011. The current target launch year of GOSAT-2 is FY2017. The objectives of GOSAT-2 include : 1) Continue and enhance spaceborne greenhouse gases observation started by GOSAT, 2) Improve our understanding of global and regional carbon cycles, and 3) Contribute to the climate change related policies as one of MRV(Measurement, Reporting, and Verification) tools for carbon emission reduction. As a scientific background/rationale of GOSAT-2, GOSAT-2 Science Plan is being edited by GOSAT-2 Science Team Preparation Committee. Not only carbon dioxide and methane but also carbon monoxide, tropospheric ozone, and aerosols are discussed in the plan. GOSAT-2 Level 2 (gas concentrations) and Level 4 (gas fluxes) products will be operationally generated at and distributed from GOSAT-2 Data Handling Facility located in NIES. In addition, a new supercomputer dedicated to GOSAT-2 research and development will be also installed in NIES. GOSAT-2 validation plan is also being discussed. Its baseline is similar to the current GOSAT . But various efforts will be made to extend the coverage of validation data for GOSAT-2. The efforts include the increased commercial passenger aircraft volunteering atmospheric measurements and additional ground-based Fourier transform spectrometers to be newly installed in Asian countries. In addition, a compact accelerator mass spectrometer is being introduced to NIES to investigate the contributions of anthropogenic emissions which is important for GOSAT-2. Climate change related policies include JCM (Joint Crediting Mechanism) in which MRV plays a critical role. MRV tools used in the existing JCM projects are mostly ground-based and site-specific. Satellite atmospheric measurements such as GOSAT or GOSAT-2 are expected to be more general and independent MRV tools and complement ground-based tools. The current status of GOSAT-2 science plan, products, validation, and application will be shown in the presentation.

  4. Computer validation in toxicology: historical review for FDA and EPA good laboratory practice.

    PubMed

    Brodish, D L

    1998-01-01

    The application of computer validation principles to Good Laboratory Practice is a fairly recent phenomenon. As automated data collection systems have become more common in toxicology facilities, the U.S. Food and Drug Administration and the U.S. Environmental Protection Agency have begun to focus inspections in this area. This historical review documents the development of regulatory guidance on computer validation in toxicology over the past several decades. An overview of the components of a computer life cycle is presented, including the development of systems descriptions, validation plans, validation testing, system maintenance, SOPs, change control, security considerations, and system retirement. Examples are provided for implementation of computer validation principles on laboratory computer systems in a toxicology facility.

  5. Development of an audit instrument for nursing care plans in the patient record

    PubMed Central

    Bjorvell, C; Thorell-Ekstrand, I; Wredling, R

    2000-01-01

    Objectives—To develop, validate, and test the reliability of an audit instrument that measures the extent to which patient records describe important aspects of nursing care. Material—Twenty records from each of three hospital wards were collected and audited. The auditors were registered nurses with a knowledge of nursing documentation in accordance with the VIPS model—a model designed to structure nursing documentation. (VIPS is an acronym formed from the Swedish words for wellbeing, integrity, prevention, and security.) Methods—An audit instrument was developed by determining specific criteria to be met. The audit questions were aimed at revealing the content of the patient for nursing assessment, nursing diagnosis, planned interventions, and outcome. Each of the 60 records was reviewed by the three auditors independently and the reliability of the instrument was tested by calculating the inter-rater reliability coefficient. Content validity was tested by using an expert panel and calculating the content validity ratio. The criterion related validity was estimated by the correlation between the score of the Cat-ch-Ing instrument and the score of an earlier developed and used audit instrument. The results were then tested by using Pearson's correlation coefficient. Results—The new audit instrument, named Cat-ch-Ing, consists of 17 questions designed to judge the nursing documentation. Both quantity and quality variables are judged on a rating scale from zero to three, with a maximum score of 80. The inter-rater reliability coefficients were 0.98, 0.98, and 0.92, respectively for each group of 20 records, the content validity ratio ranged between 0.20 and 1.0 and the criterion related validity showed a significant correlation of r = 0.68 (p< 0.0001, 95% CI 0.57 to 0.76) between the two audit instruments. Conclusion—The Cat-ch-Ing instrument has proved to be a valid and reliable audit instrument for nursing records when the VIPS model is used as the basis of the documentation. (Quality in Health Care 2000;9:6–13) Key Words: audit instrument; nursing care plans; quality assurance PMID:10848373

  6. The space shuttle payload planning working groups. Volume 8: Earth and ocean physics

    NASA Technical Reports Server (NTRS)

    1973-01-01

    The findings and recommendations of the Earth and Ocean Physics working group of the space shuttle payload planning activity are presented. The requirements for the space shuttle mission are defined as: (1) precision measurement for earth and ocean physics experiments, (2) development and demonstration of new and improved sensors and analytical techniques, (3) acquisition of surface truth data for evaluation of new measurement techniques, (4) conduct of critical experiments to validate geophysical phenomena and instrumental results, and (5) development and validation of analytical/experimental models for global ocean dynamics and solid earth dynamics/earthquake prediction. Tables of data are presented to show the flight schedule estimated costs, and the mission model.

  7. Supersonic Retropropulsion CFD Validation with Ames Unitary Plan Wind Tunnel Test Data

    NASA Technical Reports Server (NTRS)

    Schauerhamer, Daniel G.; Zarchi, Kerry A.; Kleb, William L.; Edquist, Karl T.

    2013-01-01

    A validation study of Computational Fluid Dynamics (CFD) for Supersonic Retropropulsion (SRP) was conducted using three Navier-Stokes flow solvers (DPLR, FUN3D, and OVERFLOW). The study compared results from the CFD codes to each other and also to wind tunnel test data obtained in the NASA Ames Research Center 90 70 Unitary PlanWind Tunnel. Comparisons include surface pressure coefficient as well as unsteady plume effects, and cover a range of Mach numbers, levels of thrust, and angles of orientation. The comparisons show promising capability of CFD to simulate SRP, and best agreement with the tunnel data exists for the steadier cases of the 1-nozzle and high thrust 3-nozzle configurations.

  8. Effective data validation of high-frequency data: time-point-, time-interval-, and trend-based methods.

    PubMed

    Horn, W; Miksch, S; Egghart, G; Popow, C; Paky, F

    1997-09-01

    Real-time systems for monitoring and therapy planning, which receive their data from on-line monitoring equipment and computer-based patient records, require reliable data. Data validation has to utilize and combine a set of fast methods to detect, eliminate, and repair faulty data, which may lead to life-threatening conclusions. The strength of data validation results from the combination of numerical and knowledge-based methods applied to both continuously-assessed high-frequency data and discontinuously-assessed data. Dealing with high-frequency data, examining single measurements is not sufficient. It is essential to take into account the behavior of parameters over time. We present time-point-, time-interval-, and trend-based methods for validation and repair. These are complemented by time-independent methods for determining an overall reliability of measurements. The data validation benefits from the temporal data-abstraction process, which provides automatically derived qualitative values and patterns. The temporal abstraction is oriented on a context-sensitive and expectation-guided principle. Additional knowledge derived from domain experts forms an essential part for all of these methods. The methods are applied in the field of artificial ventilation of newborn infants. Examples from the real-time monitoring and therapy-planning system VIE-VENT illustrate the usefulness and effectiveness of the methods.

  9. Status and plans for the ANOPP/HSR prediction system

    NASA Technical Reports Server (NTRS)

    Nolan, Sandra K.

    1992-01-01

    ANOPP is a comprehensive prediction system which was developed and validated by NASA. Because ANOPP is a system prediction program, it allows aerospace industry researchers to create trade-off studies with a variety of aircraft noise problems. The extensive validation of ANOPP allows the program results to be used as a benchmark for testing other prediction codes.

  10. Targeting BRCAness in Gastric Cancer

    DTIC Science & Technology

    2017-10-01

    modified CRISPR system using dCas9-KRAB expressing variants of these cells, and validated them for CRISPRi screening. These reagents will next be used...OE19 Adherent Stable Oesophagus/ gastric cardia - - - OE33 Adherent Stable Esophageal adenocarcinoma - - - Figure 2. Validation of CRISPR ...project planning and reporting Patrick O’Leary Postdoctoral Fellow UCSF PH.D. Design, execution, and interpretation of CRISPR experiments

  11. Validating Behavioural Change: Teachers' Perception and Use of ICT in England and Korea.

    ERIC Educational Resources Information Center

    Carter, D. S. G.; Leeh, D. J. K.

    This study focused on the test and cross-cultural validation of an organizational and behavioral model of planned change. The aim of the research was to ascertain the nature and direction of different cultural aspects influencing the change process when Information and Communication Technology (ICT) was being implemented in schools. The…

  12. Preparation of the implementation plan of AASHTO Mechanistic-Empirical Pavement Design Guide (M-EPDG) in Connecticut : Phase II : expanded sensitivity analysis and validation with pavement management data.

    DOT National Transportation Integrated Search

    2017-02-08

    The study re-evaluates distress prediction models using the Mechanistic-Empirical Pavement Design Guide (MEPDG) and expands the sensitivity analysis to a wide range of pavement structures and soils. In addition, an extensive validation analysis of th...

  13. Autonomously Generating Operations Sequences for a Mars Rover Using Artificial Intelligence-Based Planning

    NASA Astrophysics Data System (ADS)

    Sherwood, R.; Mutz, D.; Estlin, T.; Chien, S.; Backes, P.; Norris, J.; Tran, D.; Cooper, B.; Rabideau, G.; Mishkin, A.; Maxwell, S.

    2001-07-01

    This article discusses a proof-of-concept prototype for ground-based automatic generation of validated rover command sequences from high-level science and engineering activities. This prototype is based on ASPEN, the Automated Scheduling and Planning Environment. This artificial intelligence (AI)-based planning and scheduling system will automatically generate a command sequence that will execute within resource constraints and satisfy flight rules. An automated planning and scheduling system encodes rover design knowledge and uses search and reasoning techniques to automatically generate low-level command sequences while respecting rover operability constraints, science and engineering preferences, environmental predictions, and also adhering to hard temporal constraints. This prototype planning system has been field-tested using the Rocky 7 rover at JPL and will be field-tested on more complex rovers to prove its effectiveness before transferring the technology to flight operations for an upcoming NASA mission. Enabling goal-driven commanding of planetary rovers greatly reduces the requirements for highly skilled rover engineering personnel. This in turn greatly reduces mission operations costs. In addition, goal-driven commanding permits a faster response to changes in rover state (e.g., faults) or science discoveries by removing the time-consuming manual sequence validation process, allowing rapid "what-if" analyses, and thus reducing overall cycle times.

  14. Development of Lesson Plans and Student Worksheets Based Socio-Scientific Issues on Pollution Environmental Topic

    NASA Astrophysics Data System (ADS)

    Rahayu, S.; Meyliana, M.; Arlingga, A.; Reny, R.; Siahaan, P.; Hernani, H.

    2017-09-01

    The aim of this study is to develop lesson plans and student worksheets based socio-scientific issues on pollution environmental topic for seventh-grade junior high school students. Environmental pollution topic split into several subtopics namely air pollution, water pollution and soil pollution. The composing of lesson plans were developed based on socio-scientific issues with five stages, namely (1) Motivate; (2) Challenge; (3) Collect scientific evidence; (4) Analyse the evidence; (5) Build knowledge and make connections; and (6) Use evidence. While student worksheets contain articles on socio-scientific issues, practice, and there are a few questions to determine students’ reasoning. The method that is used in this research is research and development (R & D method). Development model used in this study is a model of Plomp that consists of four stages, namely: (1) Initial Research; (2) Design; (3) Realization or Construction; (4) Testing, evaluation and revision; (5) Implementation, while the research was limited to the fourth stage. Lesson plans and student worksheets based on socio-scientific issues was validated through an expert validation. The result showed that lesson plans and student worksheets based socio-scientific issues on pollution theme have a very decent and be able to apply in science classroom.

  15. Influences of personality traits and continuation intentions on physical activity participation within the theory of planned behaviour.

    PubMed

    Chatzisarantis, Nikos L D; Hagger, Martin S

    2008-01-01

    Previous research has suggested that the theory of planned behaviour is insufficient in capturing all the antecedents of physical activity participation and that continuation intentions or personality traits may improve the predictive validity of the model. The present study examined the combined effects of continuation intentions and personality traits on health behaviour within the theory of planned behaviour. To examine these effects, 180 university students (N = 180, Male = 87, Female = 93, Age = 19.14 years, SD = 0.94) completed self-report measures of the theory of planned behaviour, personality traits and continuation intentions. After 5 weeks, perceived achievement of behavioural outcomes and actual participation in physical activities were assessed. Results supported discriminant validity between continuation intentions, conscientiousness and extroversion and indicated that perceived achievement of behavioural outcomes and continuation intentions of failure predicted physical activity participation after controlling for personality effects, past behaviour and other variables in the theory of planned behaviour. In addition, results indicated that conscientiousness moderated the effects of continuation intentions of failure on physical activity such that continuation intentions of failure predicted physical activity participation among conscientious and not among less conscientious individuals. These findings suggest that the effects of continuation intentions on health behaviour are contingent on personality characteristics.

  16. Factors that influence planning for physical activity among workers in small- and medium-sized enterprises.

    PubMed

    Kawahara, Sawako; Tadaka, Etsuko; Okochi, Ayako

    2018-06-01

    Physical activity (PA) is necessary for improving the health of workers in small- to medium-sized enterprises (SMEs). However, behavioral changes conducive to PA are often difficult to achieve despite intentions. Because intention to perform PA does not always translate to action, proper planning may be critical for achieving PA. In this study, we aimed to identify factors related to planning for PA among workers in SMEs because this is one population that has been identified as being at higher risk for lifestyle-related diseases in Japan. Participants completed a series of validated questionnaires. Of 353 valid responses, 226 individuals (149 men; aged 47.5 ± 8.7 years) stated their intention to perform PA. Multiple regression analysis indicated that a higher PA planning score was significantly associated with higher self-efficacy for PA ( p  < 0.001), higher risk perception regarding inactivity ( p  = 0.012), and greater knowledge of information about PA community services ( p  = 0.019). Therefore, we recommend that self-efficacy, risk perception, and information regarding PA community services are enhanced in the daily working lives of workers at their workplaces. In this manner, they can promote their planning of health behavioral changes in a supportive environment, drawing upon available services, supports, and other resources.

  17. Verification, Validation, and Accreditation (VV&A) of Federations (Verification, validation et accreditation (VV&A) des federations)

    DTIC Science & Technology

    2008-04-01

    le manque de modèle universel pour la Vérification, la Validation et l’Accréditation des fédérations à cause des perspectives et besoins nationaux...federation application will depend on a number of factors, including the quality of the requirements information and the resources allocated to the VV&A...required) allocating the required functionality to federates, and developing a detailed plan for federation development and implementation. Step 4

  18. The Process of Retirement Planning Scale (PRePS): Development and Validation

    ERIC Educational Resources Information Center

    Noone, Jack H.; Stephens, Christine; Alpass, Fiona

    2010-01-01

    Although a substantial proportion of the western population is approaching retirement age, little is known about how they are preparing for the future. Much attention has been paid to the consumption of educational material and retirement wealth in the present literature, but the process of retirement planning has been ignored. S. L. Friedman and…

  19. 75 FR 56653 - Suspension of Preparation of Environmental Impact Statement for the George Bush Intercontinental...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-09-16

    ... development needs for the airport. HAS has determined that reevaluation of the Airport Master Plan (AMP.... Based on the results of the AMP, the airfield improvements being analyzed in the EIS included the... that additional planning work is necessary to ensure that the assumptions used in the AMP remain valid...

  20. A Longitudinal Study of Premarital Couples: A Social Exchange Perspective.

    ERIC Educational Resources Information Center

    Markman, Howard J.

    The attributes of couples planning to marry can affect their future relationship satisfaction. To study this phenomenon, a social exchange model was applied to a sample of couples planning to marry to assess the predictive validity of a measure of positive exchange. The longitudinal design of the two-and-a-half year investigation provided direct…

  1. The Quality of the Head Start Planned Variation Data. Volume II.

    ERIC Educational Resources Information Center

    Walker, Debbie Klein; And Others

    This publication continues the descriptions of the cognitive, psychomotor, and socioemotional measures used in all years of the Head Start Planned Variation Evaluation study. Included is a detailed examination of each measure, a discussion of the theory behind it, and a review of the available data on the measure's reliability, validity and other…

  2. Career Planning in the Medical Service Corps: Assessing the Validity of Current Guidelines through a Comparative Analysis of Duty Tours and Training Schools

    DTIC Science & Technology

    1993-03-01

    Principles of management and teatment of acute chemical warfare agent injuries. For offeirs, especially physicians and nurses, assigned to areas or...planning and problem solving. Patien Services Administration Location: Naval School of Health Sciences, Bethesda, Maryland Scope: Principles of management of

  3. Long-Term Ecological Monitoring Field Sampling Plan for 2007

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    T. Haney

    2007-07-31

    This field sampling plan describes the field investigations planned for the Long-Term Ecological Monitoring Project at the Idaho National Laboratory Site in 2007. This plan and the Quality Assurance Project Plan for Waste Area Groups 1, 2, 3, 4, 5, 6, 7, 10, and Removal Actions constitute the sampling and analysis plan supporting long-term ecological monitoring sampling in 2007. The data collected under this plan will become part of the long-term ecological monitoring data set that is being collected annually. The data will be used t determine the requirements for the subsequent long-term ecological monitoring. This plan guides the 2007more » investigations, including sampling, quality assurance, quality control, analytical procedures, and data management. As such, this plan will help to ensure that the resulting monitoring data will be scientifically valid, defensible, and of known and acceptable quality.« less

  4. Streamlining Collaborative Planning in Spacecraft Mission Architectures

    NASA Technical Reports Server (NTRS)

    Misra, Dhariti; Bopf, Michel; Fishman, Mark; Jones, Jeremy; Kerbel, Uri; Pell, Vince

    2000-01-01

    During the past two decades, the planning and scheduling community has substantially increased the capability and efficiency of individual planning and scheduling systems. Relatively recently, research work to streamline collaboration between planning systems is gaining attention. Spacecraft missions stand to benefit substantially from this work as they require the coordination of multiple planning organizations and planning systems. Up to the present time this coordination has demanded a great deal of human intervention and/or extensive custom software development efforts. This problem will become acute with increased requirements for cross-mission plan coordination and multi -spacecraft mission planning. The Advanced Architectures and Automation Branch of NASA's Goddard Space Flight Center is taking innovative steps to define collaborative planning architectures, and to identify coordinated planning tools for Cross-Mission Campaigns. Prototypes are being developed to validate these architectures and assess the usefulness of the coordination tools by the planning community. This presentation will focus on one such planning coordination too], named Visual Observation Layout Tool (VOLT), which is currently being developed to streamline the coordination between astronomical missions

  5. Airbreathing Hypersonic Technology Vision Vehicles and Development Dreams

    NASA Technical Reports Server (NTRS)

    McClinton, C. R.; Hunt, J. L.; Ricketts, R. H.; Reukauf, P.; Peddie, C. L.

    1999-01-01

    Significant advancements in hypersonic airbreathing vehicle technology have been made in the country's research centers and industry over the past 40 years. Some of that technology is being validated with the X-43 flight tests. This paper presents an overview of hypersonic airbreathing technology status within the US, and a hypersonic technology development plan. This plan builds on the nation's large investment in hypersonics. This affordable, incremental plan focuses technology development on hypersonic systems, which could be operating by the 2020's.

  6. A Study of the Communication Capabilities of the OPARS Flight Planning System for Various Levels of Demand.

    DTIC Science & Technology

    1980-03-01

    Oceanography Center (FNOC) is currently testing and evaluating a computerized flight plan system, referred to, for short, as OPARS. This sytem , developed to...replace the Lockheed Jetplan flight plan sytem , provides users at remote sites with direct access to the FNOC computer via 11 telephone lines. The...validity, but only for format. For example, an entry of ABCE , as the four- letter identification code for the destination airfield, would be accepted

  7. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Sudhyadhom, A; McGuinness, C; Descovich, M

    Purpose: To develop a methodology for validation of a Monte-Carlo dose calculation model for robotic small field SRS/SBRT deliveries. Methods: In a robotic treatment planning system, a Monte-Carlo model was iteratively optimized to match with beam data. A two-part analysis was developed to verify this model. 1) The Monte-Carlo model was validated in a simulated water phantom versus a Ray-Tracing calculation on a single beam collimator-by-collimator calculation. 2) The Monte-Carlo model was validated to be accurate in the most challenging situation, lung, by acquiring in-phantom measurements. A plan was created and delivered in a CIRS lung phantom with film insert.more » Separately, plans were delivered in an in-house created lung phantom with a PinPoint chamber insert within a lung simulating material. For medium to large collimator sizes, a single beam was delivered to the phantom. For small size collimators (10, 12.5, and 15mm), a robotically delivered plan was created to generate a uniform dose field of irradiation over a 2×2cm{sup 2} area. Results: Dose differences in simulated water between Ray-Tracing and Monte-Carlo were all within 1% at dmax and deeper. Maximum dose differences occurred prior to dmax but were all within 3%. Film measurements in a lung phantom show high correspondence of over 95% gamma at the 2%/2mm level for Monte-Carlo. Ion chamber measurements for collimator sizes of 12.5mm and above were within 3% of Monte-Carlo calculated values. Uniform irradiation involving the 10mm collimator resulted in a dose difference of ∼8% for both Monte-Carlo and Ray-Tracing indicating that there may be limitations with the dose calculation. Conclusion: We have developed a methodology to validate a Monte-Carlo model by verifying that it matches in water and, separately, that it corresponds well in lung simulating materials. The Monte-Carlo model and algorithm tested may have more limited accuracy for 10mm fields and smaller.« less

  8. Multiyear Plan for Validation of EnergyPlus Multi-Zone HVAC System Modeling using ORNL's Flexible Research Platform

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Im, Piljae; Bhandari, Mahabir S.; New, Joshua Ryan

    This document describes the Oak Ridge National Laboratory (ORNL) multiyear experimental plan for validation and uncertainty characterization of whole-building energy simulation for a multi-zone research facility using a traditional rooftop unit (RTU) as a baseline heating, ventilating, and air conditioning (HVAC) system. The project’s overarching objective is to increase the accuracy of energy simulation tools by enabling empirical validation of key inputs and algorithms. Doing so is required to inform the design of increasingly integrated building systems and to enable accountability for performance gaps between design and operation of a building. The project will produce documented data sets that canmore » be used to validate key functionality in different energy simulation tools and to identify errors and inadequate assumptions in simulation engines so that developers can correct them. ASHRAE Standard 140, Method of Test for the Evaluation of Building Energy Analysis Computer Programs (ASHRAE 2004), currently consists primarily of tests to compare different simulation programs with one another. This project will generate sets of measured data to enable empirical validation, incorporate these test data sets in an extended version of Standard 140, and apply these tests to the Department of Energy’s (DOE) EnergyPlus software (EnergyPlus 2016) to initiate the correction of any significant deficiencies. The fitness-for-purpose of the key algorithms in EnergyPlus will be established and demonstrated, and vendors of other simulation programs will be able to demonstrate the validity of their products. The data set will be equally applicable to validation of other simulation engines as well.« less

  9. WE-AB-209-05: Development of an Ultra-Fast High Quality Whole Breast Radiotherapy Treatment Planning System

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Sheng, Y; Li, T; Yoo, S

    2016-06-15

    Purpose: To enable near-real-time (<20sec) and interactive planning without compromising quality for whole breast RT treatment planning using tangential fields. Methods: Whole breast RT plans from 20 patients treated with single energy (SE, 6MV, 10 patients) or mixed energy (ME, 6/15MV, 10 patients) were randomly selected for model training. Additional 20 cases were used as validation cohort. The planning process for a new case consists of three fully automated steps:1. Energy Selection. A classification model automatically selects energy level. To build the energy selection model, principle component analysis (PCA) was applied to the digital reconstructed radiographs (DRRs) of training casesmore » to extract anatomy-energy relationship.2. Fluence Estimation. Once energy is selected, a random forest (RF) model generates the initial fluence. This model summarizes the relationship between patient anatomy’s shape based features and the output fluence. 3. Fluence Fine-tuning. This step balances the overall dose contribution throughout the whole breast tissue by automatically selecting reference points and applying centrality correction. Fine-tuning works at beamlet-level until the dose distribution meets clinical objectives. Prior to finalization, physicians can also make patient-specific trade-offs between target coverage and high-dose volumes.The proposed method was validated by comparing auto-plans with manually generated clinical-plans using Wilcoxon Signed-Rank test. Results: In 19/20 cases the model suggested the same energy combination as clinical-plans. The target volume coverage V100% was 78.1±4.7% for auto-plans, and 79.3±4.8% for clinical-plans (p=0.12). Volumes receiving 105% Rx were 69.2±78.0cc for auto-plans compared to 83.9±87.2cc for clinical-plans (p=0.13). The mean V10Gy, V20Gy of the ipsilateral lung was 24.4±6.7%, 18.6±6.0% for auto plans and 24.6±6.7%, 18.9±6.1% for clinical-plans (p=0.04, <0.001). Total computational time for auto-plans was < 20s. Conclusion: We developed an automated method that generates breast radiotherapy plans with accurate energy selection, similar target volume coverage, reduced hotspot volumes, and significant reduction in planning time, allowing for near-real-time planning.« less

  10. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Lian, Jun, E-mail: jun-lian@med.unc.edu; Chera, Bhishamjit S.; Chang, Sha

    Purpose: To build a statistical model to quantitatively correlate the anatomic features of structures and the corresponding dose-volume histogram (DVH) of head and neck (HN) Tomotherapy (Tomo) plans. To study if the model built upon one intensity modulated radiation therapy (IMRT) technique (such as conventional Linac) can be used to predict anticipated organs-at-risk (OAR) DVH of patients treated with a different IMRT technique (such as Tomo). To study if the model built upon the clinical experience of one institution can be used to aid IMRT planning for another institution. Methods: Forty-four Tomotherapy intensity modulate radiotherapy plans of HN cases (Tomo-IMRT)more » from Institution A were included in the study. A different patient group of 53 HN fixed gantry IMRT (FG-IMRT) plans was selected from Institution B. The analyzed OARs included the parotid, larynx, spinal cord, brainstem, and submandibular gland. Two major groups of anatomical features were considered: the volumetric information and the spatial information. The volume information includes the volume of target, OAR, and overlapped volume between target and OAR. The spatial information of OARs relative to PTVs was represented by the distance-to-target histogram (DTH). Important anatomical and dosimetric features were extracted from DTH and DVH by principal component analysis. Two regression models, one for Tomotherapy plan and one for IMRT plan, were built independently. The accuracy of intratreatment-modality model prediction was validated by a leave one out cross-validation method. The intertechnique and interinstitution validations were performed by using the FG-IMRT model to predict the OAR dosimetry of Tomo-IMRT plans. The dosimetry of OARs, under the same and different institutional preferences, was analyzed to examine the correlation between the model prediction and planning protocol. Results: Significant patient anatomical factors contributing to OAR dose sparing in HN Tomotherapy plans have been analyzed and identified. For all the OARs, the discrepancies of dose indices between the model predicted values and the actual plan values were within 2.1%. Similar results were obtained from the modeling of FG-IMRT plans. The parotid gland was spared in a comparable fashion during the treatment planning of two institutions. The model based on FG-IMRT plans was found to predict the median dose of the parotid of Tomotherapy plans quite well, with a mean error of 2.6%. Predictions from the FG-IMRT model suggested the median dose of the larynx, median dose of the brainstem and D2 of the brainstem could be reduced by 10.5%, 12.8%, and 20.4%, respectively, in the Tomo-IMRT plans. This was found to be correlated to the institutional differences in OAR constraint settings. Re-planning of six Tomotherapy patients confirmed the potential of optimization improvement predicted by the FG-IMRT model was correct. Conclusions: The authors established a mathematical model to correlate the anatomical features and dosimetric indexes of OARs of HN patients in Tomotherapy plans. The model can be used for the setup of patient-specific OAR dose sparing goals and quality control of planning results. The institutional clinical experience was incorporated into the model which allows the model from one institution to generate a reference plan for another institution, or another IMRT technique.« less

  11. Global Precipitation Measurement (GPM) Ground Validation (GV) Science Implementation Plan

    NASA Technical Reports Server (NTRS)

    Petersen, Walter A.; Hou, Arthur Y.

    2008-01-01

    For pre-launch algorithm development and post-launch product evaluation Global Precipitation Measurement (GPM) Ground Validation (GV) goes beyond direct comparisons of surface rain rates between ground and satellite measurements to provide the means for improving retrieval algorithms and model applications.Three approaches to GPM GV include direct statistical validation (at the surface), precipitation physics validation (in a vertical columns), and integrated science validation (4-dimensional). These three approaches support five themes: core satellite error characterization; constellation satellites validation; development of physical models of snow, cloud water, and mixed phase; development of cloud-resolving model (CRM) and land-surface models to bridge observations and algorithms; and, development of coupled CRM-land surface modeling for basin-scale water budget studies and natural hazard prediction. This presentation describes the implementation of these approaches.

  12. Using process elicitation and validation to understand and improve chemotherapy ordering and delivery.

    PubMed

    Mertens, Wilson C; Christov, Stefan C; Avrunin, George S; Clarke, Lori A; Osterweil, Leon J; Cassells, Lucinda J; Marquard, Jenna L

    2012-11-01

    Chemotherapy ordering and administration, in which errors have potentially severe consequences, was quantitatively and qualitatively evaluated by employing process formalism (or formal process definition), a technique derived from software engineering, to elicit and rigorously describe the process, after which validation techniques were applied to confirm the accuracy of the described process. The chemotherapy ordering and administration process, including exceptional situations and individuals' recognition of and responses to those situations, was elicited through informal, unstructured interviews with members of an interdisciplinary team. The process description (or process definition), written in a notation developed for software quality assessment purposes, guided process validation (which consisted of direct observations and semistructured interviews to confirm the elicited details for the treatment plan portion of the process). The overall process definition yielded 467 steps; 207 steps (44%) were dedicated to handling 59 exceptional situations. Validation yielded 82 unique process events (35 new expected but not yet described steps, 16 new exceptional situations, and 31 new steps in response to exceptional situations). Process participants actively altered the process as ambiguities and conflicts were discovered by the elicitation and validation components of the study. Chemotherapy error rates declined significantly during and after the project, which was conducted from October 2007 through August 2008. Each elicitation method and the subsequent validation discussions contributed uniquely to understanding the chemotherapy treatment plan review process, supporting rapid adoption of changes, improved communication regarding the process, and ensuing error reduction.

  13. Learning by Demonstration for Motion Planning of Upper-Limb Exoskeletons

    PubMed Central

    Lauretti, Clemente; Cordella, Francesca; Ciancio, Anna Lisa; Trigili, Emilio; Catalan, Jose Maria; Badesa, Francisco Javier; Crea, Simona; Pagliara, Silvio Marcello; Sterzi, Silvia; Vitiello, Nicola; Garcia Aracil, Nicolas; Zollo, Loredana

    2018-01-01

    The reference joint position of upper-limb exoskeletons is typically obtained by means of Cartesian motion planners and inverse kinematics algorithms with the inverse Jacobian; this approach allows exploiting the available Degrees of Freedom (i.e. DoFs) of the robot kinematic chain to achieve the desired end-effector pose; however, if used to operate non-redundant exoskeletons, it does not ensure that anthropomorphic criteria are satisfied in the whole human-robot workspace. This paper proposes a motion planning system, based on Learning by Demonstration, for upper-limb exoskeletons that allow successfully assisting patients during Activities of Daily Living (ADLs) in unstructured environment, while ensuring that anthropomorphic criteria are satisfied in the whole human-robot workspace. The motion planning system combines Learning by Demonstration with the computation of Dynamic Motion Primitives and machine learning techniques to construct task- and patient-specific joint trajectories based on the learnt trajectories. System validation was carried out in simulation and in a real setting with a 4-DoF upper-limb exoskeleton, a 5-DoF wrist-hand exoskeleton and four patients with Limb Girdle Muscular Dystrophy. Validation was addressed to (i) compare the performance of the proposed motion planning with traditional methods; (ii) assess the generalization capabilities of the proposed method with respect to the environment variability. Three ADLs were chosen to validate the system: drinking, pouring and lifting a light sphere. The achieved results showed a 100% success rate in the task fulfillment, with a high level of generalization with respect to the environment variability. Moreover, an anthropomorphic configuration of the exoskeleton is always ensured. PMID:29527161

  14. Learning by Demonstration for Motion Planning of Upper-Limb Exoskeletons.

    PubMed

    Lauretti, Clemente; Cordella, Francesca; Ciancio, Anna Lisa; Trigili, Emilio; Catalan, Jose Maria; Badesa, Francisco Javier; Crea, Simona; Pagliara, Silvio Marcello; Sterzi, Silvia; Vitiello, Nicola; Garcia Aracil, Nicolas; Zollo, Loredana

    2018-01-01

    The reference joint position of upper-limb exoskeletons is typically obtained by means of Cartesian motion planners and inverse kinematics algorithms with the inverse Jacobian; this approach allows exploiting the available Degrees of Freedom (i.e. DoFs) of the robot kinematic chain to achieve the desired end-effector pose; however, if used to operate non-redundant exoskeletons, it does not ensure that anthropomorphic criteria are satisfied in the whole human-robot workspace. This paper proposes a motion planning system, based on Learning by Demonstration, for upper-limb exoskeletons that allow successfully assisting patients during Activities of Daily Living (ADLs) in unstructured environment, while ensuring that anthropomorphic criteria are satisfied in the whole human-robot workspace. The motion planning system combines Learning by Demonstration with the computation of Dynamic Motion Primitives and machine learning techniques to construct task- and patient-specific joint trajectories based on the learnt trajectories. System validation was carried out in simulation and in a real setting with a 4-DoF upper-limb exoskeleton, a 5-DoF wrist-hand exoskeleton and four patients with Limb Girdle Muscular Dystrophy. Validation was addressed to (i) compare the performance of the proposed motion planning with traditional methods; (ii) assess the generalization capabilities of the proposed method with respect to the environment variability. Three ADLs were chosen to validate the system: drinking, pouring and lifting a light sphere. The achieved results showed a 100% success rate in the task fulfillment, with a high level of generalization with respect to the environment variability. Moreover, an anthropomorphic configuration of the exoskeleton is always ensured.

  15. Development Instrument’s Learning of Physics Through Scientific Inquiry Model Based Batak Culture to Improve Science Process Skill and Student’s Curiosity

    NASA Astrophysics Data System (ADS)

    Nasution, Derlina; Syahreni Harahap, Putri; Harahap, Marabangun

    2018-03-01

    This research aims to: (1) developed a instrument’s learning (lesson plan, worksheet, student’s book, teacher’s guide book, and instrument test) of physics learning through scientific inquiry learning model based Batak culture to achieve skills improvement process of science students and the students’ curiosity; (2) describe the quality of the result of develop instrument’s learning in high school using scientific inquiry learning model based Batak culture (lesson plan, worksheet, student’s book, teacher’s guide book, and instrument test) to achieve the science process skill improvement of students and the student curiosity. This research is research development. This research developed a instrument’s learning of physics by using a development model that is adapted from the development model Thiagarajan, Semmel, and Semmel. The stages are traversed until retrieved a valid physics instrument’s learning, practical, and effective includes :(1) definition phase, (2) the planning phase, and (3) stages of development. Test performed include expert test/validation testing experts, small groups, and test classes is limited. Test classes are limited to do in SMAN 1 Padang Bolak alternating on a class X MIA. This research resulted in: 1) the learning of physics static fluid material specially for high school grade 10th consisted of (lesson plan, worksheet, student’s book, teacher’s guide book, and instrument test) and quality worthy of use in the learning process; 2) each component of the instrument’s learning meet the criteria have valid learning, practical, and effective way to reach the science process skill improvement and curiosity in students.

  16. Targeting BRCAness in Gastric Cancer

    DTIC Science & Technology

    2017-10-01

    generated a modified CRISPR system using dCas9-KRAB expressing variants of these cells, and validated them for CRISPRi screening. These reagents will...adenocarcinoma - - - Figure 2. Validation of CRISPR activity following transduction with sgRNAs targeting CD55 and FACS staining with the anti...execution, and interpretation of CRISPR experiments Morgan Diolaiti Specialist UCSF PH.D. Experimental planning and reporting Jefferson Woods SRA

  17. Work plan for improving the DARWIN2.3 depleted material balance calculation of nuclides of interest for the fuel cycle

    NASA Astrophysics Data System (ADS)

    Rizzo, Axel; Vaglio-Gaudard, Claire; Martin, Julie-Fiona; Noguère, Gilles; Eschbach, Romain

    2017-09-01

    DARWIN2.3 is the reference package used for fuel cycle applications in France. It solves the Boltzmann and Bateman equations in a coupling way, with the European JEFF-3.1.1 nuclear data library, to compute the fuel cycle values of interest. It includes both deterministic transport codes APOLLO2 (for light water reactors) and ERANOS2 (for fast reactors), and the DARWIN/PEPIN2 depletion code, each of them being developed by CEA/DEN with the support of its industrial partners. The DARWIN2.3 package has been experimentally validated for pressurized and boiling water reactors, as well as for sodium fast reactors; this experimental validation relies on the analysis of post-irradiation experiments (PIE). The DARWIN2.3 experimental validation work points out some isotopes for which the depleted concentration calculation can be improved. Some other nuclides have no available experimental validation, and their concentration calculation uncertainty is provided by the propagation of a priori nuclear data uncertainties. This paper describes the work plan of studies initiated this year to improve the accuracy of the DARWIN2.3 depleted material balance calculation concerning some nuclides of interest for the fuel cycle.

  18. Technology Readiness of the NEXT Ion Propulsion System

    NASA Technical Reports Server (NTRS)

    Benson, Scott W.; Patterson, Michael J.

    2008-01-01

    The NASA's Evolutionary Xenon Thruster (NEXT) ion propulsion system has been in advanced technology development under the NASA In-Space Propulsion Technology project. The highest fidelity hardware planned has now been completed by the government/industry team, including: a flight prototype model (PM) thruster, an engineering model (EM) power processing unit, EM propellant management assemblies, a breadboard gimbal, and control unit simulators. Subsystem and system level technology validation testing is in progress. To achieve the objective Technology Readiness Level 6, environmental testing is being conducted to qualification levels in ground facilities simulating the space environment. Additional tests have been conducted to characterize the performance range and life capability of the NEXT thruster. This paper presents the status and results of technology validation testing accomplished to date, the validated subsystem and system capabilities, and the plans for completion of this phase of NEXT development. The next round of competed planetary science mission announcements of opportunity, and directed mission decisions, are anticipated to occur in 2008 and 2009. Progress to date, and the success of on-going technology validation, indicate that the NEXT ion propulsion system will be a primary candidate for mission consideration in these upcoming opportunities.

  19. Assessment of capabilities in persons with advanced stage of dementia: Validation of The Montessori Assessment System (MAS).

    PubMed

    Erkes, Jérôme; Camp, Cameron J; Raffard, Stéphane; Gély-Nargeot And, Marie-Christine; Bayard, Sophie

    2017-01-01

    This study evaluated the validity and reliability of the Montessori Assessment System. The Montessori Assessment System assesses preserved abilities in persons with moderate to severe dementia. In this respect, this instrument provides crucial information for the development of effective person-centered care plans. A total of 196 persons with a diagnosis of dementia in the moderate to severe stages of dementia were recruited in 10 long-term care facilities in France. All participants completed the Montessori Assessment System, the Clinical Dementia Rating Scale and/or the Mini Mental State Examination and the Severe Impairment Battery-short form. The internal consistency and temporal stability of the Montessori Assessment System were high. Additionally, good construct and divergent validity were demonstrated. Factor analysis showed a one-factor structure. The Montessori Assessment System demonstrated satisfactory psychometric properties while being a useful instrument to assess capabilities in persons with advanced stages of dementia and hence to develop person-centered plans of care.

  20. The Assessment, Development, Assurance Pharmacist's Tool (ADAPT) for ensuring quality implementation of health promotion programs.

    PubMed

    Truong, Hoai-An; Taylor, Catherine R; DiPietro, Natalie A

    2012-02-10

    To develop and validate the Assessment, Development, Assurance Pharmacist's Tool (ADAPT), an instrument for pharmacists and student pharmacists to use in developing and implementing health promotion programs. The 36-item ADAPT instrument was developed using the framework of public health's 3 core functions (assessment, policy development, and assurance) and 10 essential services. The tool's content and usage was assessed and conducted through peer-review and initial validity testing processes. Over 20 faculty members, preceptors, and student pharmacists at 5 institutions involved in planning and implementing health promotion initiatives reviewed the instrument and conducted validity testing. The instrument took approximately 15 minutes to complete and the findings resulted in changes and improvements to elements of the programs evaluated. The ADAPT instrument fills a need to more effectively plan, develop, implement, and evaluate pharmacist-directed public health programs that are evidence-based, high-quality, and compliant with laws and regulations and facilitates documentation of pharmacists' contributions to public health.

  1. Strategic planning in healthcare organizations.

    PubMed

    Rodríguez Perera, Francisco de Paula; Peiró, Manel

    2012-08-01

    Strategic planning is a completely valid and useful tool for guiding all types of organizations, including healthcare organizations. The organizational level at which the strategic planning process is relevant depends on the unit's size, its complexity, and the differentiation of the service provided. A cardiology department, a hemodynamic unit, or an electrophysiology unit can be an appropriate level, as long as their plans align with other plans at higher levels. The leader of each unit is the person responsible for promoting the planning process, a core and essential part of his or her role. The process of strategic planning is programmable, systematic, rational, and holistic and integrates the short, medium, and long term, allowing the healthcare organization to focus on relevant and lasting transformations for the future. Copyright © 2012 Sociedad Española de Cardiología. Published by Elsevier Espana. All rights reserved.

  2. Charting a path to efficiencies following a merger.

    PubMed

    Klar, Brandon; Shufelt, Gregory P

    2015-06-01

    Health systems can access the full range of opportunities for enhanced efficiencies following a merger or an acquisition by pursuing the following five-step process, which constitutes the development of a business plan of operational efficiencies: Secure executive sponsorship and involvement. Establish an integration steering committee. Develop guiding principles. Identify and validate potential efficiencies. Develop an action plan for each department and function.

  3. A Meta-Analytic Review of the Theories of Reasoned Action and Planned Behavior in Physical Activity: Predictive Validity and the Contribution of Additional Variables.

    ERIC Educational Resources Information Center

    Hagger, Martin S.; Chatzisarantis, Nikos L. D.; Biddle, Stuart J. H.

    2002-01-01

    Examined relations between behavior, intentions, attitudes, subjective norms, perceived behavioral control, self-efficacy, and past behaviors using the Theories of Reasoned Action (TRA) and Planned Behavior (TPB) in physical activity. This quantitative integration of the physical activity literature supported the major relationships of the…

  4. A Theory of Planned Behaviour-Based Analysis of TIMSS 2011 to Determine Factors Influencing Inquiry Teaching Practices in High-Performing Countries

    ERIC Educational Resources Information Center

    Pongsophon, Pongprapan; Herman, Benjamin C.

    2017-01-01

    Given the abundance of literature describing the strong relationship between inquiry-based teaching and student achievement, more should be known about the factors impacting science teachers' classroom inquiry implementation. This study utilises the theory of planned behaviour to propose and validate a causal model of inquiry-based teaching…

  5. Patient-specific cardiac phantom for clinical training and preprocedure surgical planning.

    PubMed

    Laing, Justin; Moore, John; Vassallo, Reid; Bainbridge, Daniel; Drangova, Maria; Peters, Terry

    2018-04-01

    Minimally invasive mitral valve repair procedures including MitraClip ® are becoming increasingly common. For cases of complex or diseased anatomy, clinicians may benefit from using a patient-specific cardiac phantom for training, surgical planning, and the validation of devices or techniques. An imaging compatible cardiac phantom was developed to simulate a MitraClip ® procedure. The phantom contained a patient-specific cardiac model manufactured using tissue mimicking materials. To evaluate accuracy, the patient-specific model was imaged using computed tomography (CT), segmented, and the resulting point cloud dataset was compared using absolute distance to the original patient data. The result, when comparing the molded model point cloud to the original dataset, resulted in a maximum Euclidean distance error of 7.7 mm, an average error of 0.98 mm, and a standard deviation of 0.91 mm. The phantom was validated using a MitraClip ® device to ensure anatomical features and tools are identifiable under image guidance. Patient-specific cardiac phantoms may allow for surgical complications to be accounted for preoperative planning. The information gained by clinicians involved in planning and performing the procedure should lead to shorter procedural times and better outcomes for patients.

  6. Project W-314 specific test and evaluation plan for transfer line SN-633 (241-AX-B to 241-AY-02A)

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Hays, W.H.

    1998-03-20

    The purpose of this Specific Test and Evaluation Plan (STEP) is to provide a detailed written plan for the systematic testing of modifications made by the addition of the SN-633 transfer line by the W-314 Project. The STEP develops the outline for test procedures that verify the system`s performance to the established Project design criteria. The STEP is a lower tier document based on the W-314 Test and Evaluation Plan (TEP). This STEP encompasses all testing activities required to demonstrate compliance to the project design criteria as it relates to the addition of transfer line SN-633. The Project Design Specificationsmore » (PDS) identify the specific testing activities required for the Project. Testing includes Validations and Verifications (e.g., Commercial Grade Item Dedication activities), Factory Acceptance Tests (FATs), installation tests and inspections, Construction Acceptance Tests (CATs), Acceptance Test Procedures (ATPs), Pre-Operational Test Procedures (POTPs), and Operational Test Procedures (OTPs). It should be noted that POTPs are not required for testing of the transfer line addition. The STEP will be utilized in conjunction with the TEP for verification and validation.« less

  7. A new DoD initiative: the Computational Research and Engineering Acquisition Tools and Environments (CREATE) program

    NASA Astrophysics Data System (ADS)

    Arevalo, S.; Atwood, C.; Bell, P.; Blacker, T. D.; Dey, S.; Fisher, D.; Fisher, D. A.; Genalis, P.; Gorski, J.; Harris, A.; Hill, K.; Hurwitz, M.; Kendall, R. P.; Meakin, R. L.; Morton, S.; Moyer, E. T.; Post, D. E.; Strawn, R.; Veldhuizen, D. v.; Votta, L. G.; Wynn, S.; Zelinski, G.

    2008-07-01

    In FY2008, the U.S. Department of Defense (DoD) initiated the Computational Research and Engineering Acquisition Tools and Environments (CREATE) program, a 360M program with a two-year planning phase and a ten-year execution phase. CREATE will develop and deploy three computational engineering tool sets for DoD acquisition programs to use to design aircraft, ships and radio-frequency antennas. The planning and execution of CREATE are based on the 'lessons learned' from case studies of large-scale computational science and engineering projects. The case studies stress the importance of a stable, close-knit development team; a focus on customer needs and requirements; verification and validation; flexible and agile planning, management, and development processes; risk management; realistic schedules and resource levels; balanced short- and long-term goals and deliverables; and stable, long-term support by the program sponsor. Since it began in FY2008, the CREATE program has built a team and project structure, developed requirements and begun validating them, identified candidate products, established initial connections with the acquisition programs, begun detailed project planning and development, and generated the initial collaboration infrastructure necessary for success by its multi-institutional, multidisciplinary teams.

  8. Validation of Statistical Sampling Algorithms in Visual Sample Plan (VSP): Summary Report

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Nuffer, Lisa L; Sego, Landon H.; Wilson, John E.

    2009-02-18

    The U.S. Department of Homeland Security, Office of Technology Development (OTD) contracted with a set of U.S. Department of Energy national laboratories, including the Pacific Northwest National Laboratory (PNNL), to write a Remediation Guidance for Major Airports After a Chemical Attack. The report identifies key activities and issues that should be considered by a typical major airport following an incident involving release of a toxic chemical agent. Four experimental tasks were identified that would require further research in order to supplement the Remediation Guidance. One of the tasks, Task 4, OTD Chemical Remediation Statistical Sampling Design Validation, dealt with statisticalmore » sampling algorithm validation. This report documents the results of the sampling design validation conducted for Task 4. In 2005, the Government Accountability Office (GAO) performed a review of the past U.S. responses to Anthrax terrorist cases. Part of the motivation for this PNNL report was a major GAO finding that there was a lack of validated sampling strategies in the U.S. response to Anthrax cases. The report (GAO 2005) recommended that probability-based methods be used for sampling design in order to address confidence in the results, particularly when all sample results showed no remaining contamination. The GAO also expressed a desire that the methods be validated, which is the main purpose of this PNNL report. The objective of this study was to validate probability-based statistical sampling designs and the algorithms pertinent to within-building sampling that allow the user to prescribe or evaluate confidence levels of conclusions based on data collected as guided by the statistical sampling designs. Specifically, the designs found in the Visual Sample Plan (VSP) software were evaluated. VSP was used to calculate the number of samples and the sample location for a variety of sampling plans applied to an actual release site. Most of the sampling designs validated are probability based, meaning samples are located randomly (or on a randomly placed grid) so no bias enters into the placement of samples, and the number of samples is calculated such that IF the amount and spatial extent of contamination exceeds levels of concern, at least one of the samples would be taken from a contaminated area, at least X% of the time. Hence, "validation" of the statistical sampling algorithms is defined herein to mean ensuring that the "X%" (confidence) is actually met.« less

  9. Validation of a deformable MRI to CT registration algorithm employing same day planning MRI for surrogate analysis.

    PubMed

    Padgett, Kyle R; Stoyanova, Radka; Pirozzi, Sara; Johnson, Perry; Piper, Jon; Dogan, Nesrin; Pollack, Alan

    2018-03-01

    Validating deformable multimodality image registrations is challenging due to intrinsic differences in signal characteristics and their spatial intensity distributions. Evaluating multimodality registrations using these spatial intensity distributions is also complicated by the fact that these metrics are often employed in the registration optimization process. This work evaluates rigid and deformable image registrations of the prostate in between diagnostic-MRI and radiation treatment planning-CT by utilizing a planning-MRI after fiducial marker placement as a surrogate. The surrogate allows for the direct quantitative analysis that can be difficult in the multimodality domain. For thirteen prostate patients, T2 images were acquired at two different time points, the first several weeks prior to planning (diagnostic-MRI) and the second on the same day as the planning-CT (planning-MRI). The diagnostic-MRI was deformed to the planning-CT utilizing a commercially available algorithm which synthesizes a deformable image registration (DIR) algorithm from local rigid registrations. The planning-MRI provided an independent surrogate for the planning-CT for assessing registration accuracy using image similarity metrics, including Pearson correlation and normalized mutual information (NMI). A local analysis was performed by looking only within the prostate, proximal seminal vesicles, penile bulb, and combined areas. The planning-MRI provided an excellent surrogate for the planning-CT with residual error in fiducial alignment between the two datasets being submillimeter, 0.78 mm. DIR was superior to the rigid registration in 11 of 13 cases demonstrating a 27.37% improvement in NMI (P < 0.009) within a regional area surrounding the prostate and associated critical organs. Pearson correlations showed similar results, demonstrating a 13.02% improvement (P < 0.013). By utilizing the planning-MRI as a surrogate for the planning-CT, an independent evaluation of registration accuracy is possible. This population provides an ideal testing ground for MRI to CT DIR by obviating the need for multimodality comparisons which are inherently more challenging. © 2018 The Authors. Journal of Applied Clinical Medical Physics published by Wiley Periodicals, Inc. on behalf of American Association of Physicists in Medicine.

  10. A Systematic Review to Uncover a Universal Protocol for Accuracy Assessment of 3-Dimensional Virtually Planned Orthognathic Surgery.

    PubMed

    Gaber, Ramy M; Shaheen, Eman; Falter, Bart; Araya, Sebastian; Politis, Constantinus; Swennen, Gwen R J; Jacobs, Reinhilde

    2017-11-01

    The aim of this study was to systematically review methods used for assessing the accuracy of 3-dimensional virtually planned orthognathic surgery in an attempt to reach an objective assessment protocol that could be universally used. A systematic review of the currently available literature, published until September 12, 2016, was conducted using PubMed as the primary search engine. We performed secondary searches using the Cochrane Database, clinical trial registries, Google Scholar, and Embase, as well as a bibliography search. Included articles were required to have stated clearly that 3-dimensional virtual planning was used and accuracy assessment performed, along with validation of the planning and/or assessment method. Descriptive statistics and quality assessment of included articles were performed. The initial search yielded 1,461 studies. Only 7 studies were included in our review. An important variability was found regarding methods used for 1) accuracy assessment of virtually planned orthognathic surgery or 2) validation of the tools used. Included studies were of moderate quality; reviewers' agreement regarding quality was calculated to be 0.5 using the Cohen κ test. On the basis of the findings of this review, it is evident that the literature lacks consensus regarding accuracy assessment. Hence, a protocol is suggested for accuracy assessment of virtually planned orthognathic surgery with the lowest margin of error. Copyright © 2017 American Association of Oral and Maxillofacial Surgeons. Published by Elsevier Inc. All rights reserved.

  11. Development of binomial sequential sampling plans for forecasting Listronotus maculicollis (Coleoptera: Curculionidae) larvae based on the relationship to adult counts and turfgrass damage.

    PubMed

    McGraw, Benjamin A; Koppenhöfer, Albrecht M

    2009-06-01

    Binomial sequential sampling plans were developed to forecast weevil Listronotus maculicollis Kirby (Coleoptera: Curculionidae), larval damage to golf course turfgrass and aid in the development of integrated pest management programs for the weevil. Populations of emerging overwintered adults were sampled over a 2-yr period to determine the relationship between adult counts, larval density, and turfgrass damage. Larval density and composition of preferred host plants (Poa annua L.) significantly affected the expression of turfgrass damage. Multiple regression indicates that damage may occur in moderately mixed P. annua stands with as few as 10 larvae per 0.09 m2. However, > 150 larvae were required before damage became apparent in pure Agrostis stolonifera L. plots. Adult counts during peaks in emergence as well as cumulative counts across the emergence period were significantly correlated to future densities of larvae. Eight binomial sequential sampling plans based on two tally thresholds for classifying infestation (T = 1 and two adults) and four adult density thresholds (0.5, 0.85, 1.15, and 1.35 per 3.34 m2) were developed to forecast the likelihood of turfgrass damage by using adult counts during peak emergence. Resampling for validation of sample plans software was used to validate sampling plans with field-collected data sets. All sampling plans were found to deliver accurate classifications (correct decisions were made between 84.4 and 96.8%) in a practical timeframe (average sampling cost < 22.7 min).

  12. Medical talent management: a model for physician deployment.

    PubMed

    Brightman, Baird

    2007-01-01

    This article aims to provide a focused cost-effective method for triaging physicians into appropriate non-clinical roles to benefit both doctors and healthcare organizations. Reviews a validated career-planning process and customize it for medical talent management. A structured career assessment can differentiate between different physician work styles and direct medical talent into best-fit positions. This allows healthcare organizations to create a more finely tuned career ladder than the familiar "in or out" binary choice. PRACTICAL IMPLICATIONS--Healthcare organizations can invest in cost-effective processes for the optimal utilization of their medical talent. Provides a new use for a well-validated career assessment and planning system. The actual value of this approach should be studied using best-practices in ROI research.

  13. SU-E-T-149: Brachytherapy Patient Specific Quality Assurance for a HDR Vaginal Cylinder Case

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Barbiere, J; Napoli, J; Ndlovu, A

    2015-06-15

    Purpose: Commonly Ir-192 HDR treatment planning system commissioning is only based on a single absolute measurement of source activity supplemented by tabulated parameters for multiple factors without independent verification that the planned distribution corresponds to the actual delivered dose. The purpose on this work is to present a methodology using Gafchromic film with a statistically valid calibration curve that can be used to validate clinical HDR vaginal cylinder cases by comparing the calculated plan dose distribution in a plane with the corresponding measured planar dose. Methods: A vaginal cylinder plan was created with Oncentra treatment planning system. The 3D dosemore » matrix was exported to a Varian Eclipse work station for convenient extraction of a 2D coronal dose plane corresponding to the film position. The plan was delivered with a sheet of Gafchromic EBT3 film positioned 1mm from the catheter using an Ir-192 Nucletron HDR source. The film was then digitized with an Epson 10000 XL color scanner. Film analysis is performed with MatLab imaging toolbox. A density to dose calibration curve was created using TG43 formalism for a single dwell position exposure at over 100 points for statistical accuracy. The plan and measured film dose planes were registered using a known dwell position relative to four film marks. The plan delivered 500 cGy to points 2 cm from the sources. Results: The distance to agreement of the 500 cGy isodose between the plan and film measurement laterally was 0.5 mm but can be as much as 1.5 mm superior and inferior. The difference between the computed plan dose and film measurement was calculated per pixel. The greatest errors up to 50 cGy are near the apex. Conclusion: The methodology presented will be useful to implement more comprehensive quality assurance to verify patient-specific dose distributions.« less

  14. Fontan Surgical Planning: Previous Accomplishments, Current Challenges, and Future Directions.

    PubMed

    Trusty, Phillip M; Slesnick, Timothy C; Wei, Zhenglun Alan; Rossignac, Jarek; Kanter, Kirk R; Fogel, Mark A; Yoganathan, Ajit P

    2018-04-01

    The ultimate goal of Fontan surgical planning is to provide additional insights into the clinical decision-making process. In its current state, surgical planning offers an accurate hemodynamic assessment of the pre-operative condition, provides anatomical constraints for potential surgical options, and produces decent post-operative predictions if boundary conditions are similar enough between the pre-operative and post-operative states. Moving forward, validation with post-operative data is a necessary step in order to assess the accuracy of surgical planning and determine which methodological improvements are needed. Future efforts to automate the surgical planning process will reduce the individual expertise needed and encourage use in the clinic by clinicians. As post-operative physiologic predictions improve, Fontan surgical planning will become an more effective tool to accurately model patient-specific hemodynamics.

  15. Treatment Planning and Image Guidance for Radiofrequency Ablations of Large Tumors

    PubMed Central

    Ren, Hongliang; Campos-Nanez, Enrique; Yaniv, Ziv; Banovac, Filip; Abeledo, Hernan; Hata, Nobuhiko; Cleary, Kevin

    2014-01-01

    This article addresses the two key challenges in computer-assisted percutaneous tumor ablation: planning multiple overlapping ablations for large tumors while avoiding critical structures, and executing the prescribed plan. Towards semi-automatic treatment planning for image-guided surgical interventions, we develop a systematic approach to the needle-based ablation placement task, ranging from pre-operative planning algorithms to an intra-operative execution platform. The planning system incorporates clinical constraints on ablations and trajectories using a multiple objective optimization formulation, which consists of optimal path selection and ablation coverage optimization based on integer programming. The system implementation is presented and validated in phantom studies and on an animal model. The presented system can potentially be further extended for other ablation techniques such as cryotherapy. PMID:24235279

  16. Validation of a novel robot-assisted 3DUS system for real-time planning and guidance of breast interstitial HDR brachytherapy

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Poulin, Eric; Beaulieu, Luc, E-mail: Luc.Beaulieu@phy.ulaval.ca; Gardi, Lori

    Purpose: In current clinical practice, there is no integrated 3D ultrasound (3DUS) guidance system clinically available for breast brachytherapy. In this study, the authors present a novel robot-assisted 3DUS system for real-time planning and guidance of breast interstitial high dose rate (HDR) brachytherapy treatment. Methods: For this work, a new computer controlled robotic 3DUS system was built to perform a hybrid motion scan, which is a combination of a 6 cm linear translation with a 30° rotation at both ends. The new 3DUS scanner was designed to fit on a modified Kuske assembly, keeping the current template grid configuration butmore » modifying the frame to allow the mounting of the 3DUS system at several positions. A finer grid was also tested. A user interface was developed to perform image reconstruction, semiautomatic segmentation of the surgical bed as well as catheter reconstruction and tracking. A 3D string phantom was used to validate the geometric accuracy of the reconstruction. The volumetric accuracy of the system was validated with phantoms using magnetic resonance imaging (MRI) and computed tomography (CT) images. In order to accurately determine whether 3DUS can effectively replace CT for treatment planning, the authors have compared the 3DUS catheter reconstruction to the one obtained from CT images. In addition, in agarose-based phantoms, an end-to-end procedure was performed by executing six independent complete procedures with both 14 and 16 catheters, and for both standard and finer Kuske grids. Finally, in phantoms, five end-to-end procedures were performed with the final CT planning for the validation of 3DUS preplanning. Results: The 3DUS acquisition time is approximately 10 s. A paired Student t-test showed that there was no statistical significant difference between known and measured values of string separations in each direction. Both MRI and CT volume measurements were not statistically different from 3DUS volume (Student t-test: p > 0.05) and they were significantly correlated to 3DUS measurement (Pearson test: MRI p < 0.05 and CT p < 0.001). The mean angular separation distance between catheter trajectories segmented from 3DUS and CT images was 0.42° ± 0.24°, while the maximum and mean trajectory separations were 0.51 ± 0.19 and 0.37 ± 0.17 mm, respectively. Overall, the new finer grid has performed significantly better in terms of dosimetric indices. The planning target volume dosimetric indices were not found statistically different between 3DUS and CT planning (Student t-test, p > 0.05). Both the skin and the pectoral muscle dosimetric indices were within ABS guidelines. Conclusions: A novel robot-assisted 3DUS system was designed and validated. To their knowledge, this is the first system capable of performing real-time guidance and planning of breast multicatheter HDR brachytherapy treatments. Future investigation will test the feasibility of using the system in the clinic and for permanent breast brachytherapy.« less

  17. Modification and Validation of an Automotive Data Processing Unit, Compessed Video System, and Communications Equipment

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Carter, R.J.

    1997-04-01

    The primary purpose of the "modification and validation of an automotive data processing unit (DPU), compressed video system, and communications equipment" cooperative research and development agreement (CRADA) was to modify and validate both hardware and software, developed by Scientific Atlanta, Incorporated (S-A) for defense applications (e.g., rotary-wing airplanes), for the commercial sector surface transportation domain (i.e., automobiles and trucks). S-A also furnished a state-of-the-art compressed video digital storage and retrieval system (CVDSRS), and off-the-shelf data storage and transmission equipment to support the data acquisition system for crash avoidance research (DASCAR) project conducted by Oak Ridge National Laboratory (ORNL). In turn,more » S-A received access to hardware and technology related to DASCAR. DASCAR was subsequently removed completely and installation was repeated a number of times to gain an accurate idea of complete installation, operation, and removal of DASCAR. Upon satisfactory completion of the DASCAR construction and preliminary shakedown, ORNL provided NHTSA with an operational demonstration of DASCAR at their East Liberty, OH test facility. The demonstration included an on-the-road demonstration of the entire data acquisition system using NHTSA'S test track. In addition, the demonstration also consisted of a briefing, containing the following: ORNL generated a plan for validating the prototype data acquisition system with regard to: removal of DASCAR from an existing vehicle, and installation and calibration in other vehicles; reliability of the sensors and systems; data collection and transmission process (data integrity); impact on the drivability of the vehicle and obtrusiveness of the system to the driver; data analysis procedures; conspicuousness of the vehicle to other drivers; and DASCAR installation and removal training and documentation. In order to identify any operational problems not captured by the systems testing and evaluation, the validation plan also addressed a short-term pilot research program to manipulate DASCAR under operational conditions using "naive" drivers. The effort exercised the fill capabilities of the data acquisition system. ORNL subsequently evaluated and pilot tested the data acquisition system using the validation plan. The plan was implemented in full at the NHTSA East Liberty, OH test facility, and was carried out as a cooperative effort with the Vehicle Research and Test Center staff. ORNL determined the reliability of the sensors and systems by exercising DASCAR For one vehicle type, ORNL evaluated systems reliability over a continuous period of 30 days with particular attention paid to maintenance of calibration and data integrity.« less

  18. Reliability and validity of the adolescent health profile-types.

    PubMed

    Riley, A W; Forrest, C B; Starfield, B; Green, B; Kang, M; Ensminger, M

    1998-08-01

    The purpose of this study was to demonstrate the preliminary reliability and validity of a set 13 profiles of adolescent health that describe distinct patterns of health and health service requirements on four domains of health. Reliability and validity were tested in four ethnically diverse population samples of urban and rural youths aged 11 to 17-years-old in public schools (N = 4,066). The reliability of the classification procedure and construct validity were examined in terms of the predicted and actual distributions of age, gender, race, socioeconomic status, and family type. School achievement, medical conditions, and the proportion of youths with a psychiatric disorder also were examined as tests of construct validity. The classification method was shown to produce consistent results across the four populations in terms of proportions of youths assigned with specific sociodemographic characteristics. Variations in health described by specific profiles showed expected relations to sociodemographic characteristics, family structure, school achievement, medical disorders, and psychiatric disorders. This taxonomy of health profile-types appears to effectively describe a set of patterns that characterize adolescent health. The profile-types provide a unique and practical method for identifying subgroups having distinct needs for health services, with potential utility for health policy and planning. Such integrative reporting methods are critical for more effective utilization of health status instruments in health resource planning and policy development.

  19. Discriminant content validity: a quantitative methodology for assessing content of theory-based measures, with illustrative applications.

    PubMed

    Johnston, Marie; Dixon, Diane; Hart, Jo; Glidewell, Liz; Schröder, Carin; Pollard, Beth

    2014-05-01

    In studies involving theoretical constructs, it is important that measures have good content validity and that there is not contamination of measures by content from other constructs. While reliability and construct validity are routinely reported, to date, there has not been a satisfactory, transparent, and systematic method of assessing and reporting content validity. In this paper, we describe a methodology of discriminant content validity (DCV) and illustrate its application in three studies. Discriminant content validity involves six steps: construct definition, item selection, judge identification, judgement format, single-sample test of content validity, and assessment of discriminant items. In three studies, these steps were applied to a measure of illness perceptions (IPQ-R) and control cognitions. The IPQ-R performed well with most items being purely related to their target construct, although timeline and consequences had small problems. By contrast, the study of control cognitions identified problems in measuring constructs independently. In the final study, direct estimation response formats for theory of planned behaviour constructs were found to have as good DCV as Likert format. The DCV method allowed quantitative assessment of each item and can therefore inform the content validity of the measures assessed. The methods can be applied to assess content validity before or after collecting data to select the appropriate items to measure theoretical constructs. Further, the data reported for each item in Appendix S1 can be used in item or measure selection. Statement of contribution What is already known on this subject? There are agreed methods of assessing and reporting construct validity of measures of theoretical constructs, but not their content validity. Content validity is rarely reported in a systematic and transparent manner. What does this study add? The paper proposes discriminant content validity (DCV), a systematic and transparent method of assessing and reporting whether items assess the intended theoretical construct and only that construct. In three studies, DCV was applied to measures of illness perceptions, control cognitions, and theory of planned behaviour response formats. Appendix S1 gives content validity indices for each item of each questionnaire investigated. Discriminant content validity is ideally applied while the measure is being developed, before using to measure the construct(s), but can also be applied after using a measure. © 2014 The British Psychological Society.

  20. Initial Retrieval Validation from the Joint Airborne IASI Validation Experiment (JAIVEx)

    NASA Technical Reports Server (NTRS)

    Zhou, Daniel K.; Liu, Xu; Smith, WIlliam L.; Larar, Allen M.; Taylor, Jonathan P.; Revercomb, Henry E.; Mango, Stephen A.; Schluessel, Peter; Calbet, Xavier

    2007-01-01

    The Joint Airborne IASI Validation Experiment (JAIVEx) was conducted during April 2007 mainly for validation of the Infrared Atmospheric Sounding Interferometer (IASI) on the MetOp satellite, but also included a strong component focusing on validation of the Atmospheric InfraRed Sounder (AIRS) aboard the AQUA satellite. The cross validation of IASI and AIRS is important for the joint use of their data in the global Numerical Weather Prediction process. Initial inter-comparisons of geophysical products have been conducted from different aspects, such as using different measurements from airborne ultraspectral Fourier transform spectrometers (specifically, the NPOESS Airborne Sounder Testbed Interferometer (NAST-I) and the Scanning-High resolution Interferometer Sounder (S-HIS) aboard the NASA WB-57 aircraft), UK Facility for Airborne Atmospheric Measurements (FAAM) BAe146-301 aircraft insitu instruments, dedicated dropsondes, radiosondes, and ground based Raman Lidar. An overview of the JAIVEx retrieval validation plan and some initial results of this field campaign are presented.

  1. A flexible Monte Carlo tool for patient or phantom specific calculations: comparison with preliminary validation measurements

    NASA Astrophysics Data System (ADS)

    Davidson, S.; Cui, J.; Followill, D.; Ibbott, G.; Deasy, J.

    2008-02-01

    The Dose Planning Method (DPM) is one of several 'fast' Monte Carlo (MC) computer codes designed to produce an accurate dose calculation for advanced clinical applications. We have developed a flexible machine modeling process and validation tests for open-field and IMRT calculations. To complement the DPM code, a practical and versatile source model has been developed, whose parameters are derived from a standard set of planning system commissioning measurements. The primary photon spectrum and the spectrum resulting from the flattening filter are modeled by a Fatigue function, cut-off by a multiplying Fermi function, which effectively regularizes the difficult energy spectrum determination process. Commonly-used functions are applied to represent the off-axis softening, increasing primary fluence with increasing angle ('the horn effect'), and electron contamination. The patient dependent aspect of the MC dose calculation utilizes the multi-leaf collimator (MLC) leaf sequence file exported from the treatment planning system DICOM output, coupled with the source model, to derive the particle transport. This model has been commissioned for Varian 2100C 6 MV and 18 MV photon beams using percent depth dose, dose profiles, and output factors. A 3-D conformal plan and an IMRT plan delivered to an anthropomorphic thorax phantom were used to benchmark the model. The calculated results were compared to Pinnacle v7.6c results and measurements made using radiochromic film and thermoluminescent detectors (TLD).

  2. 7 CFR 12.30 - NRCS responsibilities regarding wetlands.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... approve wetland determinations, delineations and certifications, functional assessments, mitigation plans... production of food, fiber, or horticultural crops, a certification made under this section will remain valid...

  3. The task of validation of gas-dynamic characteristics of a multistage centrifugal compressor for a natural gas booster compressor station

    NASA Astrophysics Data System (ADS)

    Danilishin, A. M.; Kozhukhov, Y. V.; Neverov, V. V.; Malev, K. G.; Mironov, Y. R.

    2017-08-01

    The aim of this work is the validation study for the numerical modeling of characteristics of a multistage centrifugal compressor for natural gas. In the research process was the analysis used grid interfaces and software systems. The result revealed discrepancies between the simulated and experimental characteristics and outlined the future work plan.

  4. Making the Transition from Diagnosis to Treatment-Planning: Validity, Reliability and Factor Structure of the Autism Spectrum Disorder Behaviour Checklist

    ERIC Educational Resources Information Center

    Bitsika, Vicki; Sharpley, Christopher F.

    2018-01-01

    The validity, reliability and factor structure of the Autism Spectrum Disorder Behaviour Checklist-Revised (ASDBC-R) were measured in a sample of 140 boys with Autism Spectrum Disorder (ASD) aged between 6 and 18 years. Internal consistency (Cronbach's alpha) was satisfactory and the ASDBC-R significantly correlated with the Social Responsiveness…

  5. Optical dosimetry probes to validate Monte Carlo and empirical-method-based NIR dose planning in the brain.

    PubMed

    Verleker, Akshay Prabhu; Shaffer, Michael; Fang, Qianqian; Choi, Mi-Ran; Clare, Susan; Stantz, Keith M

    2016-12-01

    A three-dimensional photon dosimetry in tissues is critical in designing optical therapeutic protocols to trigger light-activated drug release. The objective of this study is to investigate the feasibility of a Monte Carlo-based optical therapy planning software by developing dosimetry tools to characterize and cross-validate the local photon fluence in brain tissue, as part of a long-term strategy to quantify the effects of photoactivated drug release in brain tumors. An existing GPU-based 3D Monte Carlo (MC) code was modified to simulate near-infrared photon transport with differing laser beam profiles within phantoms of skull bone (B), white matter (WM), and gray matter (GM). A novel titanium-based optical dosimetry probe with isotropic acceptance was used to validate the local photon fluence, and an empirical model of photon transport was developed to significantly decrease execution time for clinical application. Comparisons between the MC and the dosimetry probe measurements were on an average 11.27%, 13.25%, and 11.81% along the illumination beam axis, and 9.4%, 12.06%, 8.91% perpendicular to the beam axis for WM, GM, and B phantoms, respectively. For a heterogeneous head phantom, the measured % errors were 17.71% and 18.04% along and perpendicular to beam axis. The empirical algorithm was validated by probe measurements and matched the MC results (R20.99), with average % error of 10.1%, 45.2%, and 22.1% relative to probe measurements, and 22.6%, 35.8%, and 21.9% relative to the MC, for WM, GM, and B phantoms, respectively. The simulation time for the empirical model was 6 s versus 8 h for the GPU-based Monte Carlo for a head phantom simulation. These tools provide the capability to develop and optimize treatment plans for optimal release of pharmaceuticals in the treatment of cancer. Future work will test and validate these novel delivery and release mechanisms in vivo.

  6. TU-D-201-05: Validation of Treatment Planning Dose Calculations: Experience Working with MPPG 5.a

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Xue, J; Park, J; Kim, L

    2016-06-15

    Purpose: Newly published medical physics practice guideline (MPPG 5.a.) has set the minimum requirements for commissioning and QA of treatment planning dose calculations. We present our experience in the validation of a commercial treatment planning system based on MPPG 5.a. Methods: In addition to tests traditionally performed to commission a model-based dose calculation algorithm, extensive tests were carried out at short and extended SSDs, various depths, oblique gantry angles and off-axis conditions to verify the robustness and limitations of a dose calculation algorithm. A comparison between measured and calculated dose was performed based on validation tests and evaluation criteria recommendedmore » by MPPG 5.a. An ion chamber was used for the measurement of dose at points of interest, and diodes were used for photon IMRT/VMAT validations. Dose profiles were measured with a three-dimensional scanning system and calculated in the TPS using a virtual water phantom. Results: Calculated and measured absolute dose profiles were compared at each specified SSD and depth for open fields. The disagreement is easily identifiable with the difference curve. Subtle discrepancy has revealed the limitation of the measurement, e.g., a spike at the high dose region and an asymmetrical penumbra observed on the tests with an oblique MLC beam. The excellent results we had (> 98% pass rate on 3%/3mm gamma index) on the end-to-end tests for both IMRT and VMAT are attributed to the quality beam data and the good understanding of the modeling. The limitation of the model and the uncertainty of measurement were considered when comparing the results. Conclusion: The extensive tests recommended by the MPPG encourage us to understand the accuracy and limitations of a dose algorithm as well as the uncertainty of measurement. Our experience has shown how the suggested tests can be performed effectively to validate dose calculation models.« less

  7. Chains weigh on on access. The FAH joins the throng offering proposals to solve the uninsured crisis, but some say their plan lacks a key element.

    PubMed

    Benko, Laura B

    2007-02-26

    Yet another proposal for covering the uninsured landed in the news last week, as the Federation of American Hospitals offered its plan, estimated to cost 115 dollar billion annually. While the plan drew some praise, others questioned its validity. "It's hard to take seriously a proposal that doesn't even attempt to address the fundamental issue of how all is this going to get paid for," says Susan Sherry, left.

  8. SU-F-T-76: Total Skin Electron Therapy: An-End-To-End Examination of the Absolute Dosimetry with a Rando Phantom

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Cui, G; Ha, J; Zhou, S

    Purpose: To examine and validate the absolute dose for total skin electron therapy (TSET) through an end-to-end test with a Rando phantom using optically stimulated luminescent dosimeters (OSLDs) and EBT3 radiochromic films. Methods: A Varian Trilogy linear accelerator equipped with the special procedure 6 MeV HDTSe- was used to perform TSET irradiations using a modified Stanford 6-dual-field technique. The absolute dose was calibrated using a Markus ion chamber at a reference depth of 1.3cm at 100 cm SSD with a field size of 36 × 36 cm at the isocenter in solid water slabs. The absolute dose was cross validatedmore » by a farmer ion chamber. Then the dose rate in the unit of cGy/Mu was calibrated using the Markus chamber at the treatment position. OSLDs were used to independently verify the dose using the calibrated dose rate. Finally, a patient treatment plan (200 cGy/cycle) was delivered in the QA mode to a Rando phantom, which had 16 pairs of OSLDs and EBT3 films taped onto its surface at different anatomical positions. The doses recorded were read out to validate the absolute dosimetry for TSET. Results: The OSLD measurements were within 7% agreement with the planned dose except the shoulder areas, where the doses recorded were 23% lower on average than those of the planned. The EBT3 film measurements were within 10% agreement with the planned dose except the shoulder and the scalp vertex areas, where the respective doses recorded were 18% and 14% lower on average than those of the planned. The OSLDs gave more consistent dose measurements than those of the EBT3 films. Conclusion: The absolute dosimetry for TSET was validated by an end-to-end test with a Rando phantom using the OSLDs and EBT3 films. The beam calibration and monitor unit calculations were confirmed.« less

  9. A Model-based Approach to Controlling the ST-5 Constellation Lights-Out Using the GMSEC Message Bus and Simulink

    NASA Technical Reports Server (NTRS)

    Witt, Kenneth J.; Stanley, Jason; Shendock, Robert; Mandl, Daniel

    2005-01-01

    Space Technology 5 (ST-5) is a three-satellite constellation, technology validation mission under the New Millennium Program at NASA to be launched in March 2006. One of the key technologies to be validated is a lights-out, model-based operations approach to be used for one week to control the ST-5 constellation with no manual intervention. The ground architecture features the GSFC Mission Services Evolution Center (GMSEC) middleware, which allows easy plugging in of software components and a standardized messaging protocol over a software bus. A predictive modeling tool built on MatLab's Simulink software package makes use of the GMSEC standard messaging protocol to interface to the Advanced Mission Planning System (AMPS) Scenario Scheduler which controls all activities, resource allocation and real-time re-profiling of constellation resources when non-nominal events occur. The key features of this system, which we refer to as the ST-5 Simulink system, are as follows: Original daily plan is checked to make sure that predicted resources needed are available by comparing the plan against the model. As the plan is run in real-time, the system re-profiles future activities in real-time if planned activities do not occur in the predicted timeframe or fashion. Alert messages are sent out on the GMSEC bus by the system if future predicted problems are detected. This will allow the Scenario Scheduler to correct the situation before the problem happens. The predictive model is evolved automatically over time via telemetry updates thus reducing the cost of implementing and maintaining the models by an order of magnitude from previous efforts at GSFC such as the model-based system built for MAP in the mid-1990's. This paper will describe the key features, lessons learned and implications for future missions once this system is successfully validated on-orbit in 2006.

  10. SU-D-BRB-01: A Predictive Planning Tool for Stereotactic Radiosurgery

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Palefsky, S; Roper, J; Elder, E

    Purpose: To demonstrate the feasibility of a predictive planning tool which provides SRS planning guidance based on simple patient anatomical properties: PTV size, PTV shape and distance from critical structures. Methods: Ten framed SRS cases treated at Winship Cancer Institute of Emory University were analyzed to extract data on PTV size, sphericity (shape), and distance from critical structures such as the brainstem and optic chiasm. The cases consisted of five pairs. Each pair consisted of two cases with a similar diagnosis (such as pituitary adenoma or arteriovenous malformation) that were treated with different techniques: DCA, or IMRS. A Naive Bayesmore » Classifier was trained on this data to establish the conditions under which each treatment modality was used. This model was validated by classifying ten other randomly-selected cases into DCA or IMRS classes, calculating the probability of each technique, and comparing results to the treated technique. Results: Of the ten cases used to validate the model, nine had their technique predicted correctly. The three cases treated with IMRS were all identified as such. Their probabilities of being treated with IMRS ranged between 59% and 100%. Six of the seven cases treated with DCA were correctly classified. These probabilities ranged between 51% and 95%. One case treated with DCA was incorrectly predicted to be an IMRS plan. The model’s confidence in this case was 91%. Conclusion: These findings indicate that a predictive planning tool based on simple patient anatomical properties can predict the SRS technique used for treatment. The algorithm operated with 90% accuracy. With further validation on larger patient populations, this tool may be used clinically to guide planners in choosing an appropriate treatment technique. The prediction algorithm could also be adapted to guide selection of treatment parameters such as treatment modality and number of fields for radiotherapy across anatomical sites.« less

  11. Traditional surgical planning of liver surgery is modified by 3D interactive quantitative surgical planning approach: a single-center experience with 305 patients.

    PubMed

    Wang, Xue-Dong; Wang, Hong-Guang; Shi, Jun; Duan, Wei-Dong; Luo, Ying; Ji, Wen-Bin; Zhang, Ning; Dong, Jia-Hong

    2017-06-01

    Decision making and surgical planning are to achieve the precise balance of maximal removal of target lesion, maximal sparing of functional liver remnant volume, and minimal surgical invasiveness and therefore, crucial in liver surgery. The aim of this prospective study was to validate the accuracy and predictability of 3D interactive quantitative surgical planning approach (IQSP), and to evaluate the impact of IQSP on traditional surgical plans based on 2D images. A total of 305 consecutive patients undergoing hepatectomy were included in this study. Surgical plans were created by traditional 2D approach using picture archiving and communication system (PACS) and 3D approach using IQSP respectively by two groups of physicians who did not know the surgical plans of the other group. The two surgical plans were submitted to the chief surgeon for selection before operation. The specimens were weighed. The two surgical plans were compared and analyzed retrospectively based on the operation results. The two surgical plans were successfully developed in all 305 patients and all the 3D IQSP surgical plans were selected as the final decision. Total 278 patients successfully underwent surgery, including 147 uncomplex hepatectomy and 131 complex hepatectomy. Twenty-seven patients were withdrawn from hepatectomy. In the uncomplex group, the two surgical plans were the same in all 147 patients and no statistically significant difference was found among 2D calculated resection volume (2D-RV), 3D IQSP calculated resection volume (IQSP-RV) and the specimen volume. In the complex group, the two surgical plans were different in 49 patients (49/131, 37.4%). According to the significance of differences, the 49 different patients were classified into three grades. No statistically significant difference was found between IQSP-RV and specimen volume. The coincidence rate of territory analysis of IQSP with operation was 92.1% (93/101) for 101 patients of anatomic hepatectomy. The accuracy and predictability of 3D IQSP were validated. Compared with traditional surgical planning, 3D IQSP can provide more quantitative information of anatomic structure. With the assistance of 3D IQSP, traditional surgical plans were modified to be more radical and safe.

  12. Support for Secondary Education of U.S.-Mexico Border Residents: The Construction and Validation of the Global Higher Education Support Scale (GHESS)

    ERIC Educational Resources Information Center

    Rogers, Darrin L.; Richardson, Rosalva

    2011-01-01

    Support for students before planning, planning to enter, and while enrolled in higher education is needed to ensure academic achievement, especially among U.S. Hispanics. Measures for determining the nature of student support or obstruction are necessary if we are to understand academic achievement and its development among U.S. Hispanic learners.…

  13. Highlights of science contributions to implementing the Northwest Forest Plan—1994 to 1998.

    Treesearch

    Nancy M. Diaz; Richard W. Haynes

    2002-01-01

    During 5 years of research (1994-98) in support of the Northwest Forest Plan (NWFP), Pacific Northwest Research Station scientists and their collaborators have made significant progress in both validating some of the NWFP’s major assumptions and providing research that sets the stage for further evolution of the plan. Studies have provided new information in the areas...

  14. Predicting Oral Health-Related Behaviour in the Parents of Preschool Children: An Application of the Theory of Planned Behaviour

    ERIC Educational Resources Information Center

    Van den Branden, Sigrid; Van den Broucke, Stephan; Leroy, Roos; Declerck, Dominique; Hoppenbrouwers, Karel

    2015-01-01

    Objective: This study aimed to test the predictive validity of the Theory of Planned Behaviour (TPB) when applied to the oral health-related behaviours of parents towards their preschool children in a cross-sectional and prospective design over a 5-year interval. Methods: Data for this study were obtained from parents of 1,057 children born…

  15. 40 CFR 49.23 - Federal Implementation Plan Provisions for Four Corners Power Plant, Navajo Nation.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... recertification events. When valid SO2 pounds per hour, NO2 pounds per hour, or NO2 pounds per million Btu... approval. (ii) In the event that the owner or operator is unable to develop the plan required in paragraph... requested by the Regional Administrator. (vii) In the event that a program for parameter monitoring on Units...

  16. 40 CFR 49.23 - Federal Implementation Plan Provisions for Four Corners Power Plant, Navajo Nation.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... recertification events. When valid SO2 pounds per hour, NO2 pounds per hour, or NO2 pounds per million Btu... approval. (ii) In the event that the owner or operator is unable to develop the plan required in paragraph... requested by the Regional Administrator. (vii) In the event that a program for parameter monitoring on Units...

  17. Development of Novel Therapeutics for Neglected Tropical Disease Leishmaniasis

    DTIC Science & Technology

    2015-10-01

    Approved for public release; distribution unlimited We undertook planning of kick off coordination meeting. A low dose infection model of CL was validated...A large scale synthesis of PEN optimized and in vitro studies were performed revealed that PEN alters parasite lipidome. Further studies were...Pentalinonsterol, Leishmania, cutaneous leishmaniasis, treatment Accomplishments • Undertook planning of kick off coordination meeting • Large scale synthesis of

  18. Effective learning among elite football players: the development of a football-specific self-regulated learning questionnaire.

    PubMed

    Toering, Tynke; Jordet, Geir; Ripegutu, Anders

    2013-01-01

    The present study aimed to develop a football-specific self-report instrument measuring self-regulated learning in the context of daily practice, which can be used to monitor the extent to which players take responsibility for their own learning. Development of the instrument involved six steps: 1. Literature review based on Zimmerman's (2006) theory of self-regulated learning, 2. Item generation, 3. Item validation, 4. Pilot studies, 5. Exploratory factor analysis (EFA), and 6. Confirmatory factor analysis (CFA). The instrument was tested for reliability and validity among 204 elite youth football players aged 13-16 years (Mage = 14.6; s = 0.60; 123 boys, 81 girls). The EFA indicated that a five-factor model fitted the observed data best (reflection, evaluation, planning, speaking up, and coaching). However, the CFA showed that a three-factor structure including 22 items produced a satisfactory model fit (reflection, evaluation, and planning; non-normed fit index [NNFI] = 0.96, comparative fit index [CFI] = 0.95, root mean square error of approximation [RMSEA] = 0.067). While the self-regulation processes of reflection, evaluation, and planning are strongly related and fit well into one model, other self-regulated learning processes seem to be more individually determined. In conclusion, the questionnaire developed in this study is considered a reliable and valid instrument to measure self-regulated learning among elite football players.

  19. Assessing dose rate distributions in VMAT plans

    NASA Astrophysics Data System (ADS)

    Mackeprang, P.-H.; Volken, W.; Terribilini, D.; Frauchiger, D.; Zaugg, K.; Aebersold, D. M.; Fix, M. K.; Manser, P.

    2016-04-01

    Dose rate is an essential factor in radiobiology. As modern radiotherapy delivery techniques such as volumetric modulated arc therapy (VMAT) introduce dynamic modulation of the dose rate, it is important to assess the changes in dose rate. Both the rate of monitor units per minute (MU rate) and collimation are varied over the course of a fraction, leading to different dose rates in every voxel of the calculation volume at any point in time during dose delivery. Given the radiotherapy plan and machine specific limitations, a VMAT treatment plan can be split into arc sectors between Digital Imaging and Communications in Medicine control points (CPs) of constant and known MU rate. By calculating dose distributions in each of these arc sectors independently and multiplying them with the MU rate, the dose rate in every single voxel at every time point during the fraction can be calculated. Independently calculated and then summed dose distributions per arc sector were compared to the whole arc dose calculation for validation. Dose measurements and video analysis were performed to validate the calculated datasets. A clinical head and neck, cranial and liver case were analyzed using the tool developed. Measurement validation of synthetic test cases showed linac agreement to precalculated arc sector times within  ±0.4 s and doses  ±0.1 MU (one standard deviation). Two methods for the visualization of dose rate datasets were developed: the first method plots a two-dimensional (2D) histogram of the number of voxels receiving a given dose rate over the course of the arc treatment delivery. In similarity to treatment planning system display of dose, the second method displays the dose rate as color wash on top of the corresponding computed tomography image, allowing the user to scroll through the variation over time. Examining clinical cases showed dose rates spread over a continuous spectrum, with mean dose rates hardly exceeding 100 cGy min-1 for conventional fractionation. A tool to analyze dose rate distributions in VMAT plans with sub-second accuracy was successfully developed and validated. Dose rates encountered in clinical VMAT test cases show a continuous spectrum with a mean less than or near 100 cGy min-1 for conventional fractionation.

  20. FY2017 Pilot Project Plan for the Nuclear Energy Knowledge and Validation Center Initiative

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Ren, Weiju

    To prepare for technical development of computational code validation under the Nuclear Energy Knowledge and Validation Center (NEKVAC) initiative, several meetings were held by a group of experts of the Idaho National Laboratory (INL) and the Oak Ridge National Laboratory (ORNL) to develop requirements of, and formulate a structure for, a transient fuel database through leveraging existing resources. It was concluded in discussions of these meetings that a pilot project is needed to address the most fundamental issues that can generate immediate stimulus to near-future validation developments as well as long-lasting benefits to NEKVAC operation. The present project is proposedmore » based on the consensus of these discussions. Analysis of common scenarios in code validation indicates that the incapability of acquiring satisfactory validation data is often a showstopper that must first be tackled before any confident validation developments can be carried out. Validation data are usually found scattered in different places most likely with interrelationships among the data not well documented, incomplete with information for some parameters missing, nonexistent, or unrealistic to experimentally generate. Furthermore, with very different technical backgrounds, the modeler, the experimentalist, and the knowledgebase developer that must be involved in validation data development often cannot communicate effectively without a data package template that is representative of the data structure for the information domain of interest to the desired code validation. This pilot project is proposed to use the legendary TREAT Experiments Database to provide core elements for creating an ideal validation data package. Data gaps and missing data interrelationships will be identified from these core elements. All the identified missing elements will then be filled in with experimental data if available from other existing sources or with dummy data if nonexistent. The resulting hybrid validation data package (composed of experimental and dummy data) will provide a clear and complete instance delineating the structure of the desired validation data and enabling effective communication among the modeler, the experimentalist, and the knowledgebase developer. With a good common understanding of the desired data structure by the three parties of subject matter experts, further existing data hunting will be effectively conducted, new experimental data generation will be realistically pursued, knowledgebase schema will be practically designed; and code validation will be confidently planned.« less

  1. The SCALE Verified, Archived Library of Inputs and Data - VALID

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Marshall, William BJ J; Rearden, Bradley T

    The Verified, Archived Library of Inputs and Data (VALID) at ORNL contains high quality, independently reviewed models and results that improve confidence in analysis. VALID is developed and maintained according to a procedure of the SCALE quality assurance (QA) plan. This paper reviews the origins of the procedure and its intended purpose, the philosophy of the procedure, some highlights of its implementation, and the future of the procedure and associated VALID library. The original focus of the procedure was the generation of high-quality models that could be archived at ORNL and applied to many studies. The review process associated withmore » model generation minimized the chances of errors in these archived models. Subsequently, the scope of the library and procedure was expanded to provide high quality, reviewed sensitivity data files for deployment through the International Handbook of Evaluated Criticality Safety Benchmark Experiments (IHECSBE). Sensitivity data files for approximately 400 such models are currently available. The VALID procedure and library continue fulfilling these multiple roles. The VALID procedure is based on the quality assurance principles of ISO 9001 and nuclear safety analysis. Some of these key concepts include: independent generation and review of information, generation and review by qualified individuals, use of appropriate references for design data and documentation, and retrievability of the models, results, and documentation associated with entries in the library. Some highlights of the detailed procedure are discussed to provide background on its implementation and to indicate limitations of data extracted from VALID for use by the broader community. Specifically, external users of data generated within VALID must take responsibility for ensuring that the files are used within the QA framework of their organization and that use is appropriate. The future plans for the VALID library include expansion to include additional experiments from the IHECSBE, to include experiments from areas beyond criticality safety, such as reactor physics and shielding, and to include application models. In the future, external SCALE users may also obtain qualification under the VALID procedure and be involved in expanding the library. The VALID library provides a pathway for the criticality safety community to leverage modeling and analysis expertise at ORNL.« less

  2. Proton and helium ion radiotherapy for meningioma tumors: a Monte Carlo-based treatment planning comparison.

    PubMed

    Tessonnier, Thomas; Mairani, Andrea; Chen, Wenjing; Sala, Paola; Cerutti, Francesco; Ferrari, Alfredo; Haberer, Thomas; Debus, Jürgen; Parodi, Katia

    2018-01-09

    Due to their favorable physical and biological properties, helium ion beams are increasingly considered a promising alternative to proton beams for radiation therapy. Hence, this work aims at comparing in-silico the treatment of brain and ocular meningiomas with protons and helium ions, using for the first time a dedicated Monte Carlo (MC) based treatment planning engine (MCTP) thoroughly validated both in terms of physical and biological models. Starting from clinical treatment plans of four patients undergoing proton therapy with a fixed relative biological effectiveness (RBE) of 1.1 and a fraction dose of 1.8 Gy(RBE), new treatment plans were optimized with MCTP for both protons (with variable and fixed RBE) and helium ions (with variable RBE) under the same constraints derived from the initial clinical plans. The resulting dose distributions were dosimetrically compared in terms of dose volume histograms (DVH) parameters for the planning target volume (PTV) and the organs at risk (OARs), as well as dose difference maps. In most of the cases helium ion plans provided a similar PTV coverage as protons with a consistent trend of superior OAR sparing. The latter finding was attributed to the ability of helium ions to offer sharper distal and lateral dose fall-offs, as well as a more favorable differential RBE variation in target and normal tissue. Although more studies are needed to investigate the clinical potential of helium ions for different tumour entities, the results of this work based on an experimentally validated MC engine support the promise of this modality with state-of-the-art pencil beam scanning delivery, especially in case of tumours growing in close proximity of multiple OARs such as meningiomas.

  3. Next generation terminology infrastructure to support interprofessional care planning.

    PubMed

    Collins, Sarah; Klinkenberg-Ramirez, Stephanie; Tsivkin, Kira; Mar, Perry L; Iskhakova, Dina; Nandigam, Hari; Samal, Lipika; Rocha, Roberto A

    2017-11-01

    Develop a prototype of an interprofessional terminology and information model infrastructure that can enable care planning applications to facilitate patient-centered care, learn care plan linkages and associations, provide decision support, and enable automated, prospective analytics. The study steps included a 3 step approach: (1) Process model and clinical scenario development, and (2) Requirements analysis, and (3) Development and validation of information and terminology models. Components of the terminology model include: Health Concerns, Goals, Decisions, Interventions, Assessments, and Evaluations. A terminology infrastructure should: (A) Include discrete care plan concepts; (B) Include sets of profession-specific concerns, decisions, and interventions; (C) Communicate rationales, anticipatory guidance, and guidelines that inform decisions among the care team; (D) Define semantic linkages across clinical events and professions; (E) Define sets of shared patient goals and sub-goals, including patient stated goals; (F) Capture evaluation toward achievement of goals. These requirements were mapped to AHRQ Care Coordination Measures Framework. This study used a constrained set of clinician-validated clinical scenarios. Terminology models for goals and decisions are unavailable in SNOMED CT, limiting the ability to evaluate these aspects of the proposed infrastructure. Defining and linking subsets of care planning concepts appears to be feasible, but also essential to model interprofessional care planning for common co-occurring conditions and chronic diseases. We recommend the creation of goal dynamics and decision concepts in SNOMED CT to further enable the necessary models. Systems with flexible terminology management infrastructure may enable intelligent decision support to identify conflicting and aligned concerns, goals, decisions, and interventions in shared care plans, ultimately decreasing documentation effort and cognitive burden for clinicians and patients. Copyright © 2017 Elsevier Inc. All rights reserved.

  4. A web-based team-oriented medical error communication assessment tool: development, preliminary reliability, validity, and user ratings.

    PubMed

    Kim, Sara; Brock, Doug; Prouty, Carolyn D; Odegard, Peggy Soule; Shannon, Sarah E; Robins, Lynne; Boggs, Jim G; Clark, Fiona J; Gallagher, Thomas

    2011-01-01

    Multiple-choice exams are not well suited for assessing communication skills. Standardized patient assessments are costly and patient and peer assessments are often biased. Web-based assessment using video content offers the possibility of reliable, valid, and cost-efficient means for measuring complex communication skills, including interprofessional communication. We report development of the Web-based Team-Oriented Medical Error Communication Assessment Tool, which uses videotaped cases for assessing skills in error disclosure and team communication. Steps in development included (a) defining communication behaviors, (b) creating scenarios, (c) developing scripts, (d) filming video with professional actors, and (e) writing assessment questions targeting team communication during planning and error disclosure. Using valid data from 78 participants in the intervention group, coefficient alpha estimates of internal consistency were calculated based on the Likert-scale questions and ranged from α=.79 to α=.89 for each set of 7 Likert-type discussion/planning items and from α=.70 to α=.86 for each set of 8 Likert-type disclosure items. The preliminary test-retest Pearson correlation based on the scores of the intervention group was r=.59 for discussion/planning and r=.25 for error disclosure sections, respectively. Content validity was established through reliance on empirically driven published principles of effective disclosure as well as integration of expert views across all aspects of the development process. In addition, data from 122 medicine and surgical physicians and nurses showed high ratings for video quality (4.3 of 5.0), acting (4.3), and case content (4.5). Web assessment of communication skills appears promising. Physicians and nurses across specialties respond favorably to the tool.

  5. An asthma action plan created by physician, educator and patient online collaboration with usability and visual design optimization.

    PubMed

    Gupta, Samir; Wan, Flora T; Hall, Susan E; Straus, Sharon E

    2012-01-01

    Asthma action plans (AAPs), which decrease hospitalizations and improve symptom control, are recommended in guidelines, but are seldom delivered to patients. Existing AAPs have been developed by experts, without the inclusion of all stakeholders (such as patients with asthma) and without specifically addressing usability and visual design. Our objective was to develop a more usable AAP by involving all stakeholders and considering design preferences. We created a Wiki-based system for multiuser AAP development. Pulmonologists, primary care physicians, asthma educators and patients used the system to collaboratively compile a single AAP by making multiple online selections over 1 week. We combined common elements from 3 AAPs developed in this way into 1, optimized visual design features and tested face validity in focus groups. A total of 41 participants averaged 646 selections/week over a login-time of 28.8 h/week. Of 35 participants, 28 (80%) were satisfied with the final AAP and 32 (91%) perceived that they would be able to use it. The plans created by the 3 groups were very similar, with a unanimous or majority agreement in the handling of 100/110 (91%) AAP options. Inclusion of multiple stakeholders and focus on design preferences predict enhanced usability and uptake of medical tools. The validity of our AAP is further supported by the similarity between the AAPs created by each group, user engagement and satisfaction with the plan and agreement with existing validity criteria proposed by experts. This AAP can be implemented in care with a concurrent measurement of uptake and health impact. Copyright © 2012 S. Karger AG, Basel.

  6. Radioactive waste isolation in salt: special advisory report on the status of the Office of Nuclear Waste Isolation's plans for repository performance assessment

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Ditmars, J.D.; Walbridge, E.W.; Rote, D.M.

    1983-10-01

    Repository performance assessment is analysis that identifies events and processes that might affect a repository system for isolation of radioactive waste, examines their effects on barriers to waste migration, and estimates the probabilities of their occurrence and their consequences. In 1983 Battelle Memorial Institute's Office of Nuclear Waste Isolation (ONWI) prepared two plans - one for performance assessment for a waste repository in salt and one for verification and validation of performance assessment technology. At the request of the US Department of Energy's Salt Repository Project Office (SRPO), Argonne National Laboratory reviewed those plans and prepared this report to advisemore » SRPO of specific areas where ONWI's plans for performance assessment might be improved. This report presents a framework for repository performance assessment that clearly identifies the relationships among the disposal problems, the processes underlying the problems, the tools for assessment (computer codes), and the data. In particular, the relationships among important processes and 26 model codes available to ONWI are indicated. A common suggestion for computer code verification and validation is the need for specific and unambiguous documentation of the results of performance assessment activities. A major portion of this report consists of status summaries of 27 model codes indicated as potentially useful by ONWI. The code summaries focus on three main areas: (1) the code's purpose, capabilities, and limitations; (2) status of the elements of documentation and review essential for code verification and validation; and (3) proposed application of the code for performance assessment of salt repository systems. 15 references, 6 figures, 4 tables.« less

  7. 46 CFR 189.20-15 - Scope of inspection.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... appliances, fire detecting and extinguishing equipment, pilot boarding equipment, pollution prevention... accordance with approved plans, and determine that the vessel is in possession of a valid certificate issued...

  8. 46 CFR 189.20-15 - Scope of inspection.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... appliances, fire detecting and extinguishing equipment, pilot boarding equipment, pollution prevention... accordance with approved plans, and determine that the vessel is in possession of a valid certificate issued...

  9. 46 CFR 189.20-15 - Scope of inspection.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... appliances, fire detecting and extinguishing equipment, pilot boarding equipment, pollution prevention... accordance with approved plans, and determine that the vessel is in possession of a valid certificate issued...

  10. 46 CFR 189.20-15 - Scope of inspection.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... appliances, fire detecting and extinguishing equipment, pilot boarding equipment, pollution prevention... accordance with approved plans, and determine that the vessel is in possession of a valid certificate issued...

  11. 46 CFR 189.20-15 - Scope of inspection.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... appliances, fire detecting and extinguishing equipment, pilot boarding equipment, pollution prevention... accordance with approved plans, and determine that the vessel is in possession of a valid certificate issued...

  12. Comparison of treatment plans: a retrospective study by the method of radiobiological evaluation

    NASA Astrophysics Data System (ADS)

    Puzhakkal, Niyas; Kallikuzhiyil Kochunny, Abdullah; Manthala Padannayil, Noufal; Singh, Navin; Elavan Chalil, Jumanath; Kulangarakath Umer, Jamshad

    2016-09-01

    There are many situations in radiotherapy where multiple treatment plans need to be compared for selection of an optimal plan. In this study we performed the radiobiological method of plan evaluation to verify the treatment plan comparison procedure of our clinical practice. We estimated and correlated various radiobiological dose indices with physical dose metrics for a total of 30 patients representing typical cases of head and neck, prostate and brain tumors. Three sets of plans along with a clinically approved plan (final plan) treated by either Intensity Modulated Radiation Therapy (IMRT) or Rapid Arc (RA) techniques were considered. The study yielded improved target coverage for final plans, however, no appreciable differences in doses and the complication probabilities of organs at risk were noticed. Even though all four plans showed adequate dose distributions, from dosimetric point of view, the final plan had more acceptable dose distribution. The estimated biological outcome and dose volume histogram data showed least differences between plans for IMRT when compared to RA. Our retrospective study based on 120 plans, validated the radiobiological method of plan evaluation. The tumor cure or normal tissue complication probabilities were found to be correlated with the corresponding physical dose indices.

  13. STORMVEX: The Storm Peak Lab Cloud Property Validation Experiment Science and Operations Plan

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Mace, J; Matrosov, S; Shupe, M

    2010-09-29

    During the Storm Peak Lab Cloud Property Validation Experiment (STORMVEX), a substantial correlative data set of remote sensing observations and direct in situ measurements from fixed and airborne platforms will be created in a winter season, mountainous environment. This will be accomplished by combining mountaintop observations at Storm Peak Laboratory and the airborne National Science Foundation-supported Colorado Airborne Multi-Phase Cloud Study campaign with collocated measurements from the second ARM Mobile Facility (AMF2). We describe in this document the operational plans and motivating science for this experiment, which includes deployment of AMF2 to Steamboat Springs, Colorado. The intensive STORMVEX field phasemore » will begin nominally on 1 November 2010 and extend to approximately early April 2011.« less

  14. Effects of people-centred factors on enterprise resource planning implementation project success: empirical evidence from Sri Lanka

    NASA Astrophysics Data System (ADS)

    Wickramasinghe, Vathsala; Gunawardena, Vathsala

    2010-08-01

    Extant literature suggests people-centred factors as one of the major areas influencing enterprise resource planning (ERP) implementation project success. Yet, to date, few empirical studies attempted to validate the link between people-centred factors and ERP implementation project success. The purpose of this study is to empirically identify people-centred factors that are critical to ERP implementation projects in Sri Lanka. The study develops and empirically validates a framework for people-centred factors that influence the success of ERP implementation projects. Survey research methodology was used and collected data from 74 ERP implementation projects in Sri Lanka. The people-centred factors of 'project team competence', 'rewards' and 'communication and change' were found to predict significantly the ERP implementation project success.

  15. Verification and Validation Plan for Flight Performance Requirements on the CEV Parachute Assembly System

    NASA Technical Reports Server (NTRS)

    Morris, Aaron L.; Olson, Leah M.

    2011-01-01

    The Crew Exploration Vehicle Parachute Assembly System (CPAS) is engaged in a multi-year design and test campaign aimed at qualifying a parachute recovery system for human use on the Orion Spacecraft. Orion has parachute flight performance requirements that will ultimately be verified through the use of Monte Carlo multi-degree of freedom flight simulations. These simulations will be anchored by real world flight test data and iteratively improved to provide a closer approximation to the real physics observed in the inherently chaotic inflation and steady state flight of the CPAS parachutes. This paper will examine the processes necessary to verify the flight performance requirements of the human rated spacecraft. The focus will be on the requirements verification and model validation planned on CPAS.

  16. Targeting BRCAness in Gastric Cancer

    DTIC Science & Technology

    2017-10-01

    inhibitors. We also generated a modified CRISPR system using dCas9-KRAB expressing variants of these cells, and validated them for CRISPRi screening...Figure 2. Validation of CRISPR activity following transduction with sgRNAs targeting CD55 and FACS staining with the anti-CD55 antibody. Data shown...interpretation of CRISPR experiments Morgan Diolaiti Specialist UCSF PH.D. Experimental planning and reporting Jefferson Woods SRA UCSF B.S. Perform drug

  17. Partial validation of the Dutch model for emission and transport of nutrients (STONE).

    PubMed

    Overbeek, G B; Tiktak, A; Beusen, A H; van Puijenbroek, P J

    2001-11-17

    The Netherlands has to cope with large losses of N and P to groundwater and surface water. Agriculture is the dominant source of these nutrients, particularly with reference to nutrient excretion due to intensive animal husbandry in combination with fertilizer use. The Dutch government has recently launched a stricter eutrophication abatement policy to comply with the EC nitrate directive. The Dutch consensus model for N and P emission to groundwater and surface water (STONE) has been developed to evaluate the environmental benefits of abatement plans. Due to the possibly severe socioeconomic consequences of eutrophication abatement plans, it is of utmost importance that the model is thoroughly validated. Because STONE is applied on a nationwide scale, the model validation has also been carried out on this scale. For this purpose the model outputs were compared with lumped results from monitoring networks in the upper groundwater and in surface waters. About 13,000 recent point source observations of nitrate in the upper groundwater were available, along with several hundreds of observations showing N and P in local surface water systems. Comparison of observations from the different spatial scales available showed the issue of scale to be important. Scale issues will be addressed in the next stages of the validation study.

  18. [Perceived barriers to active commuting to school: reliability and validity of a scale].

    PubMed

    Molina-García, Javier; Queralt, Ana; Estevan, Isaac; Álvarez, Octavio; Castillo, Isabel

    To examine the reliability and validity of a scale to measure perceived barriers to active commuting to school among Spanish young people. The validity of the scale was assessed in a sample of 465 adolescents (14-18 years) using a confirmatory factor analysis and studying its association with self-reported active commuting to school. The reliability of the instrument was evaluated in a sub-sample that completed the scale twice separated by a one-week interval. The results showed that the barriers scale had satisfactory fit indices, and two factors were determined. The first included environment- and safety-related items (α=0.72), while the other concerned planning and psychosocial items (α=0.64). Active commuting to school showed significant correlations with the total score of the barriers scale (rho=-0.27; p <0.001), with the environmental/safety barriers (rho=-0.22; p <0.001), as well as with the planning/psychosocial barriers (rho=-0.29; p <0.001). Test-retest ICCs for the barriers ranged from 0.68 to 0.77. The developed scale has acceptable validity and good reliability to assess barriers to active commuting to school among Spanish young people. Copyright © 2016 SESPAS. Publicado por Elsevier España, S.L.U. All rights reserved.

  19. Deep Impact Sequence Planning Using Multi-Mission Adaptable Planning Tools With Integrated Spacecraft Models

    NASA Technical Reports Server (NTRS)

    Wissler, Steven S.; Maldague, Pierre; Rocca, Jennifer; Seybold, Calina

    2006-01-01

    The Deep Impact mission was ambitious and challenging. JPL's well proven, easily adaptable multi-mission sequence planning tools combined with integrated spacecraft subsystem models enabled a small operations team to develop, validate, and execute extremely complex sequence-based activities within very short development times. This paper focuses on the core planning tool used in the mission, APGEN. It shows how the multi-mission design and adaptability of APGEN made it possible to model spacecraft subsystems as well as ground assets throughout the lifecycle of the Deep Impact project, starting with models of initial, high-level mission objectives, and culminating in detailed predictions of spacecraft behavior during mission-critical activities.

  20. Experimental Evaluation of a Planning Language Suitable for Formal Verification

    NASA Technical Reports Server (NTRS)

    Butler, Rick W.; Munoz, Cesar A.; Siminiceanu, Radu I.

    2008-01-01

    The marriage of model checking and planning faces two seemingly diverging alternatives: the need for a planning language expressive enough to capture the complexity of real-life applications, as opposed to a language simple, yet robust enough to be amenable to exhaustive verification and validation techniques. In an attempt to reconcile these differences, we have designed an abstract plan description language, ANMLite, inspired from the Action Notation Modeling Language (ANML) [17]. We present the basic concepts of the ANMLite language as well as an automatic translator from ANMLite to the model checker SAL (Symbolic Analysis Laboratory) [7]. We discuss various aspects of specifying a plan in terms of constraints and explore the implications of choosing a robust logic behind the specification of constraints, rather than simply propose a new planning language. Additionally, we provide an initial assessment of the efficiency of model checking to search for solutions of planning problems. To this end, we design a basic test benchmark and study the scalability of the generated SAL models in terms of plan complexity.

  1. Evaluation of an Expert System for the Generation of Speech and Language Therapy Plans.

    PubMed

    Robles-Bykbaev, Vladimir; López-Nores, Martín; García-Duque, Jorge; Pazos-Arias, José J; Arévalo-Lucero, Daysi

    2016-07-01

    Speech and language pathologists (SLPs) deal with a wide spectrum of disorders, arising from many different conditions, that affect voice, speech, language, and swallowing capabilities in different ways. Therefore, the outcomes of Speech and Language Therapy (SLT) are highly dependent on the accurate, consistent, and complete design of personalized therapy plans. However, SLPs often have very limited time to work with their patients and to browse the large (and growing) catalogue of activities and specific exercises that can be put into therapy plans. As a consequence, many plans are suboptimal and fail to address the specific needs of each patient. We aimed to evaluate an expert system that automatically generates plans for speech and language therapy, containing semiannual activities in the five areas of hearing, oral structure and function, linguistic formulation, expressive language and articulation, and receptive language. The goal was to assess whether the expert system speeds up the SLPs' work and leads to more accurate, consistent, and complete therapy plans for their patients. We examined the evaluation results of the SPELTA expert system in supporting the decision making of 4 SLPs treating children in three special education institutions in Ecuador. The expert system was first trained with data from 117 cases, including medical data; diagnosis for voice, speech, language and swallowing capabilities; and therapy plans created manually by the SLPs. It was then used to automatically generate new therapy plans for 13 new patients. The SLPs were finally asked to evaluate the accuracy, consistency, and completeness of those plans. A four-fold cross-validation experiment was also run on the original corpus of 117 cases in order to assess the significance of the results. The evaluation showed that 87% of the outputs provided by the SPELTA expert system were considered valid therapy plans for the different areas. The SLPs rated the overall accuracy, consistency, and completeness of the proposed activities with 4.65, 4.6, and 4.6 points (to a maximum of 5), respectively. The ratings for the subplans generated for the areas of hearing, oral structure and function, and linguistic formulation were nearly perfect, whereas the subplans for expressive language and articulation and for receptive language failed to deal properly with some of the subject cases. Overall, the SLPs indicated that over 90% of the subplans generated automatically were "better than" or "as good as" what the SLPs would have created manually if given the average time they can devote to the task. The cross-validation experiment yielded very similar results. The results show that the SPELTA expert system provides valuable input for SLPs to design proper therapy plans for their patients, in a shorter time and considering a larger set of activities than proceeding manually. The algorithms worked well even in the presence of a sparse corpus, and the evidence suggests that the system will become more reliable as it is trained with more subjects.

  2. Evaluation of an Expert System for the Generation of Speech and Language Therapy Plans

    PubMed Central

    López-Nores, Martín; García-Duque, Jorge; Pazos-Arias, José J; Arévalo-Lucero, Daysi

    2016-01-01

    Background Speech and language pathologists (SLPs) deal with a wide spectrum of disorders, arising from many different conditions, that affect voice, speech, language, and swallowing capabilities in different ways. Therefore, the outcomes of Speech and Language Therapy (SLT) are highly dependent on the accurate, consistent, and complete design of personalized therapy plans. However, SLPs often have very limited time to work with their patients and to browse the large (and growing) catalogue of activities and specific exercises that can be put into therapy plans. As a consequence, many plans are suboptimal and fail to address the specific needs of each patient. Objective We aimed to evaluate an expert system that automatically generates plans for speech and language therapy, containing semiannual activities in the five areas of hearing, oral structure and function, linguistic formulation, expressive language and articulation, and receptive language. The goal was to assess whether the expert system speeds up the SLPs’ work and leads to more accurate, consistent, and complete therapy plans for their patients. Methods We examined the evaluation results of the SPELTA expert system in supporting the decision making of 4 SLPs treating children in three special education institutions in Ecuador. The expert system was first trained with data from 117 cases, including medical data; diagnosis for voice, speech, language and swallowing capabilities; and therapy plans created manually by the SLPs. It was then used to automatically generate new therapy plans for 13 new patients. The SLPs were finally asked to evaluate the accuracy, consistency, and completeness of those plans. A four-fold cross-validation experiment was also run on the original corpus of 117 cases in order to assess the significance of the results. Results The evaluation showed that 87% of the outputs provided by the SPELTA expert system were considered valid therapy plans for the different areas. The SLPs rated the overall accuracy, consistency, and completeness of the proposed activities with 4.65, 4.6, and 4.6 points (to a maximum of 5), respectively. The ratings for the subplans generated for the areas of hearing, oral structure and function, and linguistic formulation were nearly perfect, whereas the subplans for expressive language and articulation and for receptive language failed to deal properly with some of the subject cases. Overall, the SLPs indicated that over 90% of the subplans generated automatically were “better than” or “as good as” what the SLPs would have created manually if given the average time they can devote to the task. The cross-validation experiment yielded very similar results. Conclusions The results show that the SPELTA expert system provides valuable input for SLPs to design proper therapy plans for their patients, in a shorter time and considering a larger set of activities than proceeding manually. The algorithms worked well even in the presence of a sparse corpus, and the evidence suggests that the system will become more reliable as it is trained with more subjects. PMID:27370070

  3. The National Shipbuilding Research Program. Shipyard MACT Implementation Plan and Compliance Tools

    DTIC Science & Technology

    1996-06-01

    display a currently valid OMB control number. 1. REPORT DATE JUN 1996 2. REPORT TYPE N/A 3. DATES COVERED - 4. TITLE AND SUBTITLE The National...ACHIEVABLE CONTROL TECHNOLOGY SECTION TWO: MODEL SHIPYARD IMPLEMENTATION PLAN SECTION THREE: THINNING RATION CALCULATION SHEETS FOR OPTIONS 2 & 3 AND...INTERPRETATION OF THE SHIPYARD MAXIMUM ACHIEVABLE CONTROL TECHNOLOGY EPA’s Maximum Achievable Control Technology Rule for Shipyards: A Plain English

  4. Municipal resilience: A paradigm shift in emergency and continuity management.

    PubMed

    Solecki, Greg; Luchia, Mike

    More than a decade of emergency and continuity management vision was instrumental in providing the unprecedented level of response and recovery from the great flood of 2013. Earlier assessments, planning and validation promulgated development of corporate continuity, emergency and contingency plans along with tactical, strategic and recovery operations centres that all led to a reliable emergency management model that will continue to provide the backbone for municipal resilience.

  5. Why Do College Students Cheat? A Structural Equation Modeling Validation of the Theory of Planned Behavior

    ERIC Educational Resources Information Center

    AL-Dossary, Saeed Abdullah

    2017-01-01

    Cheating on tests is a serious problem in education. The purpose of this study was to test the efficacy of a modified form of the theory of planned behavior (TPB) to predict cheating behavior among a sample of Saudi university students. This study also sought to test the influence of cheating in high school on cheating in college within the…

  6. Supporting the Use of CERT (registered trademark) Secure Coding Standards in DoD Acquisitions

    DTIC Science & Technology

    2012-07-01

    Capability Maturity Model IntegrationSM (CMMI®) [Davis 2009]. SM Team Software Process, TSP, and Capability Maturity Model Integration are service...STP Software Test Plan TEP Test and Evaluation Plan TSP Team Software Process V & V verification and validation CMU/SEI-2012-TN-016 | 47...Supporting the Use of CERT® Secure Coding Standards in DoD Acquisitions Tim Morrow ( Software Engineering Institute) Robert Seacord ( Software

  7. SBKF Modeling and Analysis Plan: Buckling Analysis of Compression-Loaded Orthogrid and Isogrid Cylinders

    NASA Technical Reports Server (NTRS)

    Lovejoy, Andrew E.; Hilburger, Mark W.

    2013-01-01

    This document outlines a Modeling and Analysis Plan (MAP) to be followed by the SBKF analysts. It includes instructions on modeling and analysis formulation and execution, model verification and validation, identifying sources of error and uncertainty, and documentation. The goal of this MAP is to provide a standardized procedure that ensures uniformity and quality of the results produced by the project and corresponding documentation.

  8. Renewing focus on family planning service quality globally.

    PubMed

    Hancock, Nancy L; Stuart, Gretchen S; Tang, Jennifer H; Chibwesha, Carla J; Stringer, Jeffrey S A; Chi, Benjamin H

    2016-01-01

    Reducing the global unmet need for contraception is currently a priority for many governments, multi-lateral initiatives, non-governmental organizations, and donors. Evidence strongly suggests that the provision of quality family planning services can increase uptake, prevalence, and continuation of contraception. While an accepted framework to define the components of family planning service quality exists, translating this framework into assessment tools that are accessible, easily utilized, and valid for service providers has remained a challenge. We propose new approaches to improve the standardization and accessibility of family planning service quality assessment tools to simplify family planning service quality evaluation. With easier approaches to program evaluation, quality improvements can be performed more swiftly to help increase uptake and continuation of contraception to improve the health of women and their families.

  9. A Strategy to Establish a Quality Assurance/Quality Control Plan for the Application of Biosensors for the Detection of E. coli in Water.

    PubMed

    Hesari, Nikou; Kıratlı Yılmazçoban, Nursel; Elzein, Mohamad; Alum, Absar; Abbaszadegan, Morteza

    2017-01-03

    Rapid bacterial detection using biosensors is a novel approach for microbiological testing applications. Validation of such methods is an obstacle in the adoption of new bio-sensing technologies for water testing. Therefore, establishing a quality assurance and quality control (QA/QC) plan is essential to demonstrate accuracy and reliability of the biosensor method for the detection of E. coli in drinking water samples. In this study, different reagents and assay conditions including temperatures, holding time, E. coli strains and concentrations, dissolving agents, salinity and pH effects, quality of substrates of various suppliers of 4-methylumbelliferyl glucuronide (MUG), and environmental water samples were included in the QA/QC plan and used in the assay optimization and documentation. Furthermore, the procedural QA/QC for the monitoring of drinking water samples was established to validate the performance of the biosensor platform for the detection of E. coli using a culture-based standard technique. Implementing the developed QA/QC plan, the same level of precision and accuracy was achieved using both the standard and the biosensor methods. The established procedural QA/QC for the biosensor will provide a reliable tool for a near real-time monitoring of E. coli in drinking water samples to both industry and regulatory authorities.

  10. The Performance Analysis of AN Indoor Mobile Mapping System with Rgb-D Sensor

    NASA Astrophysics Data System (ADS)

    Tsai, G. J.; Chiang, K. W.; Chu, C. H.; Chen, Y. L.; El-Sheimy, N.; Habib, A.

    2015-08-01

    Over the years, Mobile Mapping Systems (MMSs) have been widely applied to urban mapping, path management and monitoring and cyber city, etc. The key concept of mobile mapping is based on positioning technology and photogrammetry. In order to achieve the integration, multi-sensor integrated mapping technology has clearly established. In recent years, the robotic technology has been rapidly developed. The other mapping technology that is on the basis of low-cost sensor has generally used in robotic system, it is known as the Simultaneous Localization and Mapping (SLAM). The objective of this study is developed a prototype of indoor MMS for mobile mapping applications, especially to reduce the costs and enhance the efficiency of data collection and validation of direct georeferenced (DG) performance. The proposed indoor MMS is composed of a tactical grade Inertial Measurement Unit (IMU), the Kinect RGB-D sensor and light detection, ranging (LIDAR) and robot. In summary, this paper designs the payload for indoor MMS to generate the floor plan. In first session, it concentrates on comparing the different positioning algorithms in the indoor environment. Next, the indoor plans are generated by two sensors, Kinect RGB-D sensor LIDAR on robot. Moreover, the generated floor plan will compare with the known plan for both validation and verification.

  11. A National Residue Control Plan from the analytical perspective--the Brazilian case.

    PubMed

    Mauricio, Angelo de Q; Lins, Erick S; Alvarenga, Marcelo B

    2009-04-01

    Food safety is a strategic topic entailing not only national public health aspects but also competitiveness in international trade. An important component of any food safety program is the control and monitoring of residues posed by certain substances involved in food production. In turn, a National Residue Control Plan (NRCP) relies on an appropriate laboratory network, not only to generate analytical results, but also more broadly to verify and co-validate the controls built along the food production chain. Therefore laboratories operating under a NRCP should work in close cooperation with inspection bodies, fostering the critical alignment of the whole system with the principles of risk analysis. Beyond producing technically valid results, these laboratories should arguably be able to assist in the prediction and establishment of targets for official control. In pursuit of analytical excellence, the Brazilian government has developed a strategic plan for Official Agricultural Laboratories. Inserted in a national agenda for agricultural risk analysis, the plan has succeeded in raising laboratory budget by approximately 200%, it has started a rigorous program for personnel capacity-building, it has initiated strategic cooperation with international reference centres, and finally, it has completely renewed instrumental resources and rapidly triggered a program aimed at full laboratory compliance with ISO/IEC 17025 requirements.

  12. Space Weather Modeling Services at the Community Coordinated Modeling Center

    NASA Technical Reports Server (NTRS)

    Hesse, Michael

    2006-01-01

    The Community Coordinated Modeling Center (CCMC) is a multi-agency partnership, which aims at the creation of next generation space weather models. The goal of the CCMC is to support the research and developmental work necessary to substantially increase the present-day modeling capability for space weather purposes, and to provide models for transition to the Rapid Prototyping Centers at the space weather forecast centers. This goal requires close collaborations with and substantial involvement of the research community. The physical regions to be addressed by CCMC-related activities range from the solar atmosphere to the Earth's upper atmosphere. The CCMC is an integral part of the National Space Weather Program Implementation Plan, of NASA's Living With a Star (LWS) initiative, and of the Department of Defense Space Weather Transition Plan. CCMC includes a facility at NASA Goddard Space Flight Center. CCMC also provides, to the research community, access to state-of-the-art space research models. In this paper we will provide a description of the current CCMC status, discuss current plans, research and development accomplishments and goals, and describe the model testing and validation process undertaken as part of the CCMC mandate. Special emphasis will be on solar and heliospheric models currently residing at CCMC, and on plans for validation and verification.

  13. Space Weather Modeling at the Community Coordinated Modeling Center

    NASA Technical Reports Server (NTRS)

    Hesse M.

    2005-01-01

    The Community Coordinated Modeling Center (CCMC) is a multi-agency partnership, which aims at the creation of next generation space weather models. The goal of the CCMC is to support the research and developmental work necessary to substantially increase the present-day modeling capability for space weather purposes, and to provide models for transition to the rapid prototyping centers at the space weather forecast centers. This goal requires dose collaborations with and substantial involvement of the research community. The physical regions to be addressed by CCMC-related activities range from the solar atmosphere to the Earth's upper atmosphere. The CCMC is an integral part of the National Space Weather Program Implementation Plan, of NASA's Living With a Star (LWS) initiative, and of the Department of Defense Space Weather Transition Plan. CCMC includes a facility at NASA Goddard Space Flight Center, as well as distributed computing facilities provided by the US Air Force. CCMC also provides, to the research community, access to state-of-the-art space research models. In this paper we will provide updates on CCMC status, on current plans, research and development accomplishments and goals, and on the model testing and validation process undertaken as part of the CCMC mandate. Special emphasis will be on solar and heliospheric models currently residing at CCMC, and on plans for validation and verification.

  14. A Strategy to Establish a Quality Assurance/Quality Control Plan for the Application of Biosensors for the Detection of E. coli in Water

    PubMed Central

    Hesari, Nikou; Kıratlı Yılmazçoban, Nursel; Elzein, Mohamad; Alum, Absar; Abbaszadegan, Morteza

    2017-01-01

    Rapid bacterial detection using biosensors is a novel approach for microbiological testing applications. Validation of such methods is an obstacle in the adoption of new bio-sensing technologies for water testing. Therefore, establishing a quality assurance and quality control (QA/QC) plan is essential to demonstrate accuracy and reliability of the biosensor method for the detection of E. coli in drinking water samples. In this study, different reagents and assay conditions including temperatures, holding time, E. coli strains and concentrations, dissolving agents, salinity and pH effects, quality of substrates of various suppliers of 4-methylumbelliferyl glucuronide (MUG), and environmental water samples were included in the QA/QC plan and used in the assay optimization and documentation. Furthermore, the procedural QA/QC for the monitoring of drinking water samples was established to validate the performance of the biosensor platform for the detection of E. coli using a culture-based standard technique. Implementing the developed QA/QC plan, the same level of precision and accuracy was achieved using both the standard and the biosensor methods. The established procedural QA/QC for the biosensor will provide a reliable tool for a near real-time monitoring of E. coli in drinking water samples to both industry and regulatory authorities. PMID:28054956

  15. Data Validation Package - June 2016 Groundwater and Surface Water Sampling at the Green River, Utah, Disposal Site

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Linard, Joshua; Price, Jeffrey

    This event included annual sampling of groundwater and surface water locations at the Green River, Utah, Disposal Site. Sampling and analyses were conducted as specified in Sampling and Analysis Plan for US. Department of Energy Office of Legacy Management Sites (LMS/PRO/S04351, continually updated, http://energy.gov/lrnldownloads/sampling-and- analysis-plan-us-department-energy-office-legacy-management-sites). Samples were collected from 15 monitoring wells and two surface locations at the disposal site as specified in the draft 2011 Ground Water Compliance Action Plan for the Green River, Utah, Disposal Site. Planned monitoring locations are shown in Attachment 1, Sampling and Analysis Work Order. A duplicate sample was collected from location 0179. Onemore » equipment blank was collected during this sampling event. Water levels were measured at all monitoring wells that were sampled. See Attachment 2, Trip Reports for additional details. The analytical data and associated qualifiers can be viewed in environmental database reports and are also available for viewing with dynamic mapping via the GEMS (Geospatial Environmental Mapping System) website at http://gems.lm.doe.gov/#. No issues were identified during the data validation process that requires additional action or follow-up.« less

  16. Validation of a Parametric Approach for 3d Fortification Modelling: Application to Scale Models

    NASA Astrophysics Data System (ADS)

    Jacquot, K.; Chevrier, C.; Halin, G.

    2013-02-01

    Parametric modelling approach applied to cultural heritage virtual representation is a field of research explored for years since it can address many limitations of digitising tools. For example, essential historical sources for fortification virtual reconstructions like plans-reliefs have several shortcomings when they are scanned. To overcome those problems, knowledge based-modelling can be used: knowledge models based on the analysis of theoretical literature of a specific domain such as bastioned fortification treatises can be the cornerstone of the creation of a parametric library of fortification components. Implemented in Grasshopper, these components are manually adjusted on the data available (i.e. 3D surveys of plans-reliefs or scanned maps). Most of the fortification area is now modelled and the question of accuracy assessment is raised. A specific method is used to evaluate the accuracy of the parametric components. The results of the assessment process will allow us to validate the parametric approach. The automation of the adjustment process can finally be planned. The virtual model of fortification is part of a larger project aimed at valorising and diffusing a very unique cultural heritage item: the collection of plans-reliefs. As such, knowledge models are precious assets when automation and semantic enhancements will be considered.

  17. Prediction of exercise in patients across various stages of bariatric surgery: a comparison of the merits of the theory of reasoned action versus the theory of planned behavior.

    PubMed

    Hunt, Hillary R; Gross, Alan M

    2009-11-01

    Obesity is a world-wide health concern approaching epidemic proportions. Successful long-term treatment involves a combination of bariatric surgery, diet, and exercise. Social cognitive models, such as the Theory of Reasoned Action (TRA) and the Theory of Planned Behavior (TPB), are among the most commonly tested theories utilized in the prediction of exercise. As exercise is not a completely volitional behavior, it is hypothesized that the TPB is a superior theoretical model for the prediction of exercise intentions and behavior. This study tested validity of the TPB in a sample of bariatric patients and further validated its improvement over the TRA in predicting exercise adherence at different operative stages. Results generally confirmed research hypotheses. Superiority of the TPB model was validated in this sample of bariatric patients, and Perceived Behavioral Control emerged as the single-best predictor of both exercise intentions and self-reported behavior. Finally, results suggested that both subjective norms and attitudes toward exercise played a larger role in the prediction of intention and behavior than previously reported.

  18. Development plan for the External Hazards Experimental Group. Light Water Reactor Sustainability Program

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Coleman, Justin Leigh; Smith, Curtis Lee; Burns, Douglas Edward

    This report describes the development plan for a new multi-partner External Hazards Experimental Group (EHEG) coordinated by Idaho National Laboratory (INL) within the Risk-Informed Safety Margin Characterization (RISMC) technical pathway of the Light Water Reactor Sustainability Program. Currently, there is limited data available for development and validation of the tools and methods being developed in the RISMC Toolkit. The EHEG is being developed to obtain high-quality, small- and large-scale experimental data validation of RISMC tools and methods in a timely and cost-effective way. The group of universities and national laboratories that will eventually form the EHEG (which is ultimately expectedmore » to include both the initial participants and other universities and national laboratories that have been identified) have the expertise and experimental capabilities needed to both obtain and compile existing data archives and perform additional seismic and flooding experiments. The data developed by EHEG will be stored in databases for use within RISMC. These databases will be used to validate the advanced external hazard tools and methods.« less

  19. Optical Closed-Loop Propulsion Control System Development

    NASA Technical Reports Server (NTRS)

    Poppel, Gary L.

    1998-01-01

    The overall objective of this program was to design and fabricate the components required for optical closed-loop control of a F404-400 turbofan engine, by building on the experience of the NASA Fiber Optic Control System Integration (FOCSI) program. Evaluating the performance of fiber optic technology at the component and system levels will result in helping to validate its use on aircraft engines. This report includes descriptions of three test plans. The EOI Acceptance Test is designed to demonstrate satisfactory functionality of the EOI, primarily fail-safe throughput of the F404 sensor signals in the normal mode, and validation, switching, and output of the five analog sensor signals as generated from validated optical sensor inputs, in the optical mode. The EOI System Test is designed to demonstrate acceptable F404 ECU functionality as interfaced with the EOI, making use of a production ECU test stand. The Optical Control Engine Test Request describes planned hardware installation, optical signal calibrations, data system coordination, test procedures, and data signal comparisons for an engine test demonstration of the optical closed-loop control.

  20. Evaluation of Informed Choice for contraceptive methods among women attending a family planning program: conceptual development; a case study in Chile.

    PubMed

    Valdés, Patricio R; Alarcon, Ana M; Munoz, Sergio R

    2013-03-01

    To generate and validate a scale to measure the Informed Choice of contraceptive methods among women attending a family health care service in Chile. The study follows a multimethod design that combined expert opinions from 13 physicians, 3 focus groups of 21 women each, and a sample survey of 1,446 women. Data analysis consisted of a qualitative text analysis of group interviews, a factor analysis for construct validity, and kappa statistic and Cronbach alpha to assess scale reliability. The instrument comprises 25 items grouped into six categories: information and orientation, quality of treatment, communication, participation in decision making, expression of reproductive rights, and method access and availability. Internal consistency measured with Cronbach alpha ranged from 0.75 to 0.89 for all subscales (kappa, 0.62; standard deviation, 0.06), and construct validity was demonstrated from the testing of several hypotheses. The use of mixed methods contributed to developing a scale of Informed Choice that was culturally appropriate for assessing the women who participated in the family planning program. Copyright © 2013 Elsevier Inc. All rights reserved.

  1. Performance validation of the ANSER control laws for the F-18 HARV

    NASA Technical Reports Server (NTRS)

    Messina, Michael D.

    1995-01-01

    The ANSER control laws were implemented in Ada by NASA Dryden for flight test on the High Alpha Research Vehicle (HARV). The Ada implementation was tested in the hardware-in-the-loop (HIL) simulation, and results were compared to those obtained with the NASA Langley batch Fortran implementation of the control laws which are considered the 'truth model.' This report documents the performance validation test results between these implementations. This report contains the ANSER performance validation test plan, HIL versus batch time-history comparisons, simulation scripts used to generate checkcases, and detailed analysis of discrepancies discovered during testing.

  2. Performance validation of the ANSER Control Laws for the F-18 HARV

    NASA Technical Reports Server (NTRS)

    Messina, Michael D.

    1995-01-01

    The ANSER control laws were implemented in Ada by NASA Dryden for flight test on the High Alpha Research Vehicle (HARV). The Ada implementation was tested in the hardware-in-the-loop (HIL) simulation, and results were compared to those obtained with the NASA Langley batch Fortran implementation of the control laws which are considered the 'truth model'. This report documents the performance validation test results between these implementations. This report contains the ANSER performance validation test plan, HIL versus batch time-history comparisons, simulation scripts used to generate checkcases, and detailed analysis of discrepancies discovered during testing.

  3. Validation of the ENVISAT atmospheric chemistry instruments

    NASA Astrophysics Data System (ADS)

    Snoeij, P.; Koopman, R.; Attema, E.; Zehner, C.; Wursteisen, P.; Dehn, A.; de Laurentius, M.; Frerick, J.; Mantovani, R.; Saavedra de Miguel, L.

    Three atmospheric-chemistry sensors form part of the ENVISAT payload that has been placed into orbit in March 2002. This paper presents the ENVISAT mission status and data policy, and reviews the end-to-end performance of the GOMOS, MIPAS and SCIAMACHY observation systems and will discuss the validation aspects of these instruments. In particular, for each instrument, the review addresses mission planning, in-orbit performance, calibration, data processor algorithms and configuration, reprocessing strategy, and product quality control assessment. An important part of the quality assessment is the Geophysical Validation. At the ACVT Validation workshop held in Frascati, Italy, from 3-7 May 2004, scientists and engineers presented analyses of the exhaustive series of tests that have been run on each of ENVISAT atmospheric chemistry sensors since the spacecraft was launched in March 2002. On the basis of workshop results it was decided that most of the data products provided by the ENVISAT atmospheric chemistry instruments are ready for operational delivery. Although the main validation phase for the atmospheric instruments of ENVISAT will be completed soon, ongoing validation products will continue throughout the lifetime of the ENVISAT mission. The long-term validation phase will: Provide assurance of data quality and accuracy for applications such as climate change research Investigate the fully representative range of geophysical conditions Investigate the fully representative range of seasonal cycles Perform long term monitoring for instrumental drifts and other artefacts Validate new products. This paper will also discuss the general status of the validation activities for GOMOS, MIPAS and SCIAMACHY. The main and long-term geophysical validation programme will be presented. The flight and ground-segment planning, configuration and performance characterization will be discussed. The evolution of each of the observation systems has been distinct during the mission history: the GOMOS instrument operation has undergone an important change, and its processing chain is subject of two upgrades. For MIPAS intervention on one of the on-board subsystems has proven necessary, and an important data processing improvement cycle has been completed through reconfiguration of the processing chain. SCIAMACHY operations have required only minor interventions, and the presentation will focus on the processing chain evolution.

  4. Robot path planning using a genetic algorithm

    NASA Technical Reports Server (NTRS)

    Cleghorn, Timothy F.; Baffes, Paul T.; Wang, Liu

    1988-01-01

    Robot path planning can refer either to a mobile vehicle such as a Mars Rover, or to an end effector on an arm moving through a cluttered workspace. In both instances there may exist many solutions, some of which are better than others, either in terms of distance traversed, energy expended, or joint angle or reach capabilities. A path planning program has been developed based upon a genetic algorithm. This program assumes global knowledge of the terrain or workspace, and provides a family of good paths between the initial and final points. Initially, a set of valid random paths are constructed. Successive generations of valid paths are obtained using one of several possible reproduction strategies similar to those found in biological communities. A fitness function is defined to describe the goodness of the path, in this case including length, slope, and obstacle avoidance considerations. It was found that with some reproduction strategies, the average value of the fitness function improved for successive generations, and that by saving the best paths of each generation, one could quite rapidly obtain a collection of good candidate solutions.

  5. Planning Model of Physics Learning In Senior High School To Develop Problem Solving Creativity Based On National Standard Of Education

    NASA Astrophysics Data System (ADS)

    Putra, A.; Masril, M.; Yurnetti, Y.

    2018-04-01

    One of the causes of low achievement of student’s competence in physics learning in high school is the process which they have not been able to develop student’s creativity in problem solving. This is shown that the teacher’s learning plan is not accordance with the National Eduction Standard. This study aims to produce a reconstruction model of physics learning that fullfil the competency standards, content standards, and assessment standards in accordance with applicable curriculum standards. The development process follows: Needs analysis, product design, product development, implementation, and product evaluation. The research process involves 2 peers judgment, 4 experts judgment and two study groups of high school students in Padang. The data obtained, in the form of qualitative and quantitative data that collected through documentation, observation, questionnaires, and tests. The result of this research up to the product development stage that obtained the physics learning plan model that meets the validity of the content and the validity of the construction in terms of the fulfillment of Basic Competence, Content Standards, Process Standards and Assessment Standards.

  6. International Space Station Payload Operations Integration Center (POIC) Overview

    NASA Technical Reports Server (NTRS)

    Ijames, Gayleen N.

    2012-01-01

    Objectives and Goals: Maintain and operate the POIC and support integrated Space Station command and control functions. Provide software and hardware systems to support ISS payloads and Shuttle for the POIF cadre, Payload Developers and International Partners. Provide design, development, independent verification &validation, configuration, operational product/system deliveries and maintenance of those systems for telemetry, commanding, database and planning. Provide Backup Control Center for MCC-H in case of shutdown. Provide certified personnel and systems to support 24x7 facility operations per ISS Program. Payloads CoFR Implementation Plan (SSP 52054) and MSFC Payload Operations CoFR Implementation Plan (POIF-1006).

  7. Evaluation of the deformation and corresponding dosimetric implications in prostate cancer treatment

    NASA Astrophysics Data System (ADS)

    Wen, Ning; Glide-Hurst, Carri; Nurushev, Teamour; Xing, Lei; Kim, Jinkoo; Zhong, Hualiang; Liu, Dezhi; Liu, Manju; Burmeister, Jay; Movsas, Benjamin; Chetty, Indrin J.

    2012-09-01

    The cone-beam computed tomography (CBCT) imaging modality is an integral component of image-guided adaptive radiation therapy (IGART), which uses patient-specific dynamic/temporal information for potential treatment plan modification. In this study, an offline process for the integral component IGART framework has been implemented that consists of deformable image registration (DIR) and its validation, dose reconstruction, dose accumulation and dose verification. This study compares the differences between planned and estimated delivered doses under an IGART framework of five patients undergoing prostate cancer radiation therapy. The dose calculation accuracy on CBCT was verified by measurements made in a Rando pelvic phantom. The accuracy of DIR on patient image sets was evaluated in three ways: landmark matching with fiducial markers, visual image evaluation and unbalanced energy (UE); UE has been previously demonstrated to be a feasible method for the validation of DIR accuracy at a voxel level. The dose calculated on each CBCT image set was reconstructed and accumulated over all fractions to reflect the ‘actual dose’ delivered to the patient. The deformably accumulated (delivered) plans were then compared to the original (static) plans to evaluate tumor and normal tissue dose discrepancies. The results support the utility of adaptive planning, which can be used to fully elucidate the dosimetric impact based on the simulated delivered dose to achieve the desired tumor control and normal tissue sparing, which may be of particular importance in the context of hypofractionated radiotherapy regimens.

  8. Quantitative validation of a computer-aided maxillofacial planning system, focusing on soft tissue deformations.

    PubMed

    Nadjmi, Nasser; Defrancq, Ellen; Mollemans, Wouter; Hemelen, Geert Van; Bergé, Stefaan

    2014-01-01

    The aim of this study was to evaluate the accuracy of 3D soft tissue predictions generated by a computer-aided maxillofacial planning system in patients undergoing orthognathic surgery. Twenty patients with dentofacial dysmorphosis were treated with orthognathic surgery after a preoperative orthodontic treatment. Fourteen patients had an Angle Class II malocclusion; three patients had an Angle class III malocclusion, and three patients had an Angle Class I malocclusion. Skeletal asymmetry was observed in six patient. The surgeries were planned using the Maxilim software. Computer assisted surgical planning was transferred to the patient by digitally generated splints. The validation procedures were performed in the following steps: (1) Standardized registration of the pre- and postoperative Cone Beam CT volumes; (2) Automated adjustment of the bone-related planning to the actual operative bony displacement; (3) Simulation of soft tissue changes; (4) Calculation of the soft tissue differences between the predicted and the postoperative results by distance mapping. Eighty four percent of the mapped distances between the predicted and actual postoperative results measured between -2 mm and +2 mm. The mean absolute linear measurements between the predicted and actual postoperative surface was 1.18. Our study shows the overall prediction was dependent on neither the surgical procedures nor the dentofacial deformity type. Despite some shortcomings in the prediction of the final position of the lower lip and cheek area, this software promises a clinically acceptable soft tissue prediction for orthognathic surgical procedures.

  9. Cost-effective binomial sequential sampling of western bean cutworm, Striacosta albicosta (Lepidoptera: Noctuidae), egg masses in corn.

    PubMed

    Paula-Moraes, S; Burkness, E C; Hunt, T E; Wright, R J; Hein, G L; Hutchison, W D

    2011-12-01

    Striacosta albicosta (Smith) (Lepidoptera: Noctuidae), is a native pest of dry beans (Phaseolus vulgaris L.) and corn (Zea mays L.). As a result of larval feeding damage on corn ears, S. albicosta has a narrow treatment window; thus, early detection of the pest in the field is essential, and egg mass sampling has become a popular monitoring tool. Three action thresholds for field and sweet corn currently are used by crop consultants, including 4% of plants infested with egg masses on sweet corn in the silking-tasseling stage, 8% of plants infested with egg masses on field corn with approximately 95% tasseled, and 20% of plants infested with egg masses on field corn during mid-milk-stage corn. The current monitoring recommendation is to sample 20 plants at each of five locations per field (100 plants total). In an effort to develop a more cost-effective sampling plan for S. albicosta egg masses, several alternative binomial sampling plans were developed using Wald's sequential probability ratio test, and validated using Resampling for Validation of Sampling Plans (RVSP) software. The benefit-cost ratio also was calculated and used to determine the final selection of sampling plans. Based on final sampling plans selected for each action threshold, the average sample number required to reach a treat or no-treat decision ranged from 38 to 41 plants per field. This represents a significant savings in sampling cost over the current recommendation of 100 plants.

  10. I Plan Therefore I Choose: Free-Choice Bias Due to Prior Action-Probability but Not Action-Value

    PubMed Central

    Suriya-Arunroj, Lalitta; Gail, Alexander

    2015-01-01

    According to an emerging view, decision-making, and motor planning are tightly entangled at the level of neural processing. Choice is influenced not only by the values associated with different options, but also biased by other factors. Here we test the hypothesis that preliminary action planning can induce choice biases gradually and independently of objective value when planning overlaps with one of the potential action alternatives. Subjects performed center-out reaches obeying either a clockwise or counterclockwise cue-response rule in two tasks. In the probabilistic task, a pre-cue indicated the probability of each of the two potential rules to become valid. When the subsequent rule-cue unambiguously indicated which of the pre-cued rules was actually valid (instructed trials), subjects responded faster to rules pre-cued with higher probability. When subjects were allowed to choose freely between two equally rewarded rules (choice trials) they chose the originally more likely rule more often and faster, despite the lack of an objective advantage in selecting this target. In the amount task, the pre-cue indicated the amount of potential reward associated with each rule. Subjects responded faster to rules pre-cued with higher reward amount in instructed trials of the amount task, equivalent to the more likely rule in the probabilistic task. Yet, in contrast, subjects showed hardly any choice bias and no increase in response speed in favor of the original high-reward target in the choice trials of the amount task. We conclude that free-choice behavior is robustly biased when predictability encourages the planning of one of the potential responses, while prior reward expectations without action planning do not induce such strong bias. Our results provide behavioral evidence for distinct contributions of expected value and action planning in decision-making and a tight interdependence of motor planning and action selection, supporting the idea that the underlying neural mechanisms overlap. PMID:26635565

  11. A New, Integrated Approach to Army Operational Testing and Evaluation

    DTIC Science & Technology

    1977-11-04

    simulation should be reviewed to determine if there are areas that may or could produce data to support OT. During the Validation Phase the operational...II must provide the data for a valid estimate of the system’s military utility, operational effectiveness and operational suitability (including...the necessity of planning to acquire supplementary data . This data may be derived by analysis or obtained in tests (contractor, development and/or

  12. Risk Management Approach & Progress in Cd and Cr6+ Elimination

    DTIC Science & Technology

    2014-11-18

    Documentation Available by 2015? Gaps Conversion Coating- Aluminum Avionics/Electrical- Class 3 9 7 Medium yes- joint service/OEM/ NASA effort to...Optimized conditions validated by NASA . – FRC validation: immersion process – Based on data from the lab Surtec 650V optimization, an 1800-gallon tank...acting similarly, 650V not • Plans: scale up to 80 gallon process line; assess Metalast TCP/HF- EPA and Henkel products; further study 650V

  13. Nursing diagnosis of grieving: content validity in perinatal loss situations.

    PubMed

    Paloma-Castro, Olga; Romero-Sánchez, José Manuel; Paramio-Cuevas, Juan Carlos; Pastor-Montero, Sonia María; Castro-Yuste, Cristina; Frandsen, Anna J; Albar-Marín, María Jesús; Bas-Sarmiento, Pilar; Moreno-Corral, Luis Javier

    2014-06-01

    To validate the content of the NANDA-I nursing diagnosis of grieving in situations of perinatal loss. Using the Fehring's model, 208 Spanish experts were asked to assess the adequacy of the defining characteristics and other manifestations identified in the literature for cases of perinatal loss. The content validity index was 0.867. Twelve of the 18 defining characteristics were validated, seven as major and five as minor. From the manifestations proposed, "empty inside" was considered as major. The nursing diagnosis of grieving fits in content to the cases of perinatal loss according to experts. The results have provided evidence to support the use of the diagnosis in care plans for said clinical situation. © 2013 NANDA International.

  14. Pavement performance testing : research implementation plan.

    DOT National Transportation Integrated Search

    2005-01-01

    STATEMENT OF NEED: Validate effect of materials variables in the Superpave mix design system as : affects rutting and fatigue performance. : RESEARCH OBJECTIVES: 1. Determine the effect of aggregate characteristics and gradation and polymer modifier ...

  15. 78 FR 20141 - Agency Information Collection Activities; Proposed Collection; Comments Requested: National Drug...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-04-03

    ..., Domestic Strategic Intelligence Unit, Office of Intelligence, Warning, Plans and Programs, Drug Enforcement... proposed collection of information, including the validity of the methodology and assumptions used; Enhance...

  16. Evaluation of Guidelines for Subgrade Treatments

    DOT National Transportation Integrated Search

    2005-02-01

    ODOT has recently developed guidelines for subgrade treatments to be used during plan : development and construction. This study evaluates these guidelines by comparing them with : existing guidelines developed elsewhere and validating them through c...

  17. Collecting and Using Student Information for School Improvement.

    ERIC Educational Resources Information Center

    Riegel, N. Blyth

    1989-01-01

    Describes a Texas school district's attempt to determine highly effective and valid data for management decision-making and to increase managers' access to this data. Common sense and planning expertise helped immeasurably. (MLH)

  18. Collaborative Planning of Robotic Exploration

    NASA Technical Reports Server (NTRS)

    Norris, Jeffrey; Backes, Paul; Powell, Mark; Vona, Marsette; Steinke, Robert

    2004-01-01

    The Science Activity Planner (SAP) software system includes an uplink-planning component, which enables collaborative planning of activities to be undertaken by an exploratory robot on a remote planet or on Earth. Included in the uplink-planning component is the SAP-Uplink Browser, which enables users to load multiple spacecraft activity plans into a single window, compare them, and merge them. The uplink-planning component includes a subcomponent that implements the Rover Markup Language Activity Planning format (RML-AP), based on the Extensible Markup Language (XML) format that enables the representation, within a single document, of planned spacecraft and robotic activities together with the scientific reasons for the activities. Each such document is highly parseable and can be validated easily. Another subcomponent of the uplink-planning component is the Activity Dictionary Markup Language (ADML), which eliminates the need for two mission activity dictionaries - one in a human-readable format and one in a machine-readable format. Style sheets that have been developed along with the ADML format enable users to edit one dictionary in a user-friendly environment without compromising

  19. Validation of Serum Markers for the Early Detection of Hepatocellular Carcinoma — EDRN Public Portal

    Cancer.gov

    Using the guidelines for cancer biomarker validation suggested by Pepe et al. (23), we propose to perform a Phase 2 study of DCP for the detection of early stage HCC. In this proposal, we plan to perform a larger case-control study to compare the sensitivity and specificity of DCP and AFP alone and in combination in differentiating patients with all stages of HCC and more importantly those with early HCC from patients with cirrhosis. We plan to enroll consecutive patients with HCC seen at 7 centers in the United States. Controls are frequency matched to cases (all center combined) using the following criteria: age (±10 years), gender (+10%) and etiology of liver disease (viral vs non-viral (+5%). Within each participating institution, there will be an equal number (+20%) of cases and controls.

  20. Real-world use of the risk-need-responsivity model and the level of service/case management inventory with community-supervised offenders.

    PubMed

    Dyck, Heather L; Campbell, Mary Ann; Wershler, Julie L

    2018-06-01

    The risk-need-responsivity model (RNR; Bonta & Andrews, 2017) has become a leading approach for effective offender case management, but field tests of this model are still required. The present study first assessed the predictive validity of the RNR-informed Level of Service/Case Management Inventory (LS/CMI; Andrews, Bonta, & Wormith, 2004) with a sample of Atlantic Canadian male and female community-supervised provincial offenders (N = 136). Next, the case management plans prepared from these LS/CMI results were analyzed for adherence to the principles of risk, need, and responsivity. As expected, the LS/CMI was a strong predictor of general recidivism for both males (area under the curve = .75, 95% confidence interval [.66, .85]), and especially females (area under the curve = .94, 95% confidence interval [.84, 1.00]), over an average 3.42-year follow-up period. The LS/CMI was predictive of time to recidivism, with lower risk cases taking longer to reoffend than higher risk cases. Despite the robust predictive validity of the LS/CMI, case management plans developed by probation officers generally reflected poor adherence to the RNR principles. These findings highlight the need for better training on how to transfer risk appraisal information from valid risk tools to case plans to better meet the best-practice principles of risk, need, and responsivity for criminal behavior risk reduction. (PsycINFO Database Record (c) 2018 APA, all rights reserved).

  1. STAR-CCM+ Verification and Validation Plan

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Pointer, William David

    2016-09-30

    The commercial Computational Fluid Dynamics (CFD) code STAR-CCM+ provides general purpose finite volume method solutions for fluid dynamics and energy transport. This document defines plans for verification and validation (V&V) of the base code and models implemented within the code by the Consortium for Advanced Simulation of Light water reactors (CASL). The software quality assurance activities described herein are port of the overall software life cycle defined in the CASL Software Quality Assurance (SQA) Plan [Sieger, 2015]. STAR-CCM+ serves as the principal foundation for development of an advanced predictive multi-phase boiling simulation capability within CASL. The CASL Thermal Hydraulics Methodsmore » (THM) team develops advanced closure models required to describe the subgrid-resolution behavior of secondary fluids or fluid phases in multiphase boiling flows within the Eulerian-Eulerian framework of the code. These include wall heat partitioning models that describe the formation of vapor on the surface and the forces the define bubble/droplet dynamic motion. The CASL models are implemented as user coding or field functions within the general framework of the code. This report defines procedures and requirements for V&V of the multi-phase CFD capability developed by CASL THM. Results of V&V evaluations will be documented in a separate STAR-CCM+ V&V assessment report. This report is expected to be a living document and will be updated as additional validation cases are identified and adopted as part of the CASL THM V&V suite.« less

  2. Evaluating physician performance at individualizing care: a pilot study tracking contextual errors in medical decision making.

    PubMed

    Weiner, Saul J; Schwartz, Alan; Yudkowsky, Rachel; Schiff, Gordon D; Weaver, Frances M; Goldberg, Julie; Weiss, Kevin B

    2007-01-01

    Clinical decision making requires 2 distinct cognitive skills: the ability to classify patients' conditions into diagnostic and management categories that permit the application of research evidence and the ability to individualize or-more specifically-to contextualize care for patients whose circumstances and needs require variation from the standard approach to care. The purpose of this study was to develop and test a methodology for measuring physicians' performance at contextualizing care and compare it to their performance at planning biomedically appropriate care. First, the authors drafted 3 cases, each with 4 variations, 3 of which are embedded with biomedical and/or contextual information that is essential to planning care. Once the cases were validated as instruments for assessing physician performance, 54 internal medicine residents were then presented with opportunities to make these preidentified biomedical or contextual errors, and data were collected on information elicitation and error making. The case validation process was successful in that, in the final iteration, the physicians who received the contextual variant of cases proposed an alternate plan of care to those who received the baseline variant 100% of the time. The subsequent piloting of these validated cases unmasked previously unmeasured differences in physician performance at contextualizing care. The findings, which reflect the performance characteristics of the study population, are presented. This pilot study demonstrates a methodology for measuring physician performance at contextualizing care and illustrates the contribution of such information to an overall assessment of physician practice.

  3. Validation of the Oncentra Brachy Advanced Collapsed cone Engine for a commercial (192)Ir source using heterogeneous geometries.

    PubMed

    Ma, Yunzhi; Lacroix, Fréderic; Lavallée, Marie-Claude; Beaulieu, Luc

    2015-01-01

    To validate the Advanced Collapsed cone Engine (ACE) dose calculation engine of Oncentra Brachy (OcB) treatment planning system using an (192)Ir source. Two levels of validation were performed, conformant to the model-based dose calculation algorithm commissioning guidelines of American Association of Physicists in Medicine TG-186 report. Level 1 uses all-water phantoms, and the validation is against TG-43 methodology. Level 2 uses real-patient cases, and the validation is against Monte Carlo (MC) simulations. For each case, the ACE and TG-43 calculations were performed in the OcB treatment planning system. ALGEBRA MC system was used to perform MC simulations. In Level 1, the ray effect depends on both accuracy mode and the number of dwell positions. The volume fraction with dose error ≥2% quickly reduces from 23% (13%) for a single dwell to 3% (2%) for eight dwell positions in the standard (high) accuracy mode. In Level 2, the 10% and higher isodose lines were observed overlapping between ACE (both standard and high-resolution modes) and MC. Major clinical indices (V100, V150, V200, D90, D50, and D2cc) were investigated and validated by MC. For example, among the Level 2 cases, the maximum deviation in V100 of ACE from MC is 2.75% but up to ~10% for TG-43. Similarly, the maximum deviation in D90 is 0.14 Gy between ACE and MC but up to 0.24 Gy for TG-43. ACE demonstrated good agreement with MC in most clinically relevant regions in the cases tested. Departure from MC is significant for specific situations but limited to low-dose (<10% isodose) regions. Copyright © 2015 American Brachytherapy Society. Published by Elsevier Inc. All rights reserved.

  4. Development, test-retest reliability and validity of the Pharmacy Value-Added Services Questionnaire (PVASQ).

    PubMed

    Tan, Christine L; Hassali, Mohamed A; Saleem, Fahad; Shafie, Asrul A; Aljadhey, Hisham; Gan, Vincent B

    2015-01-01

    (i) To develop the Pharmacy Value-Added Services Questionnaire (PVASQ) using emerging themes generated from interviews. (ii) To establish reliability and validity of questionnaire instrument. Using an extended Theory of Planned Behavior as the theoretical model, face-to-face interviews generated salient beliefs of pharmacy value-added services. The PVASQ was constructed initially in English incorporating important themes and later translated into the Malay language with forward and backward translation. Intention (INT) to adopt pharmacy value-added services is predicted by attitudes (ATT), subjective norms (SN), perceived behavioral control (PBC), knowledge and expectations. Using a 7-point Likert-type scale and a dichotomous scale, test-retest reliability (N=25) was assessed by administrating the questionnaire instrument twice at an interval of one week apart. Internal consistency was measured by Cronbach's alpha and construct validity between two administrations was assessed using the kappa statistic and the intraclass correlation coefficient (ICC). Confirmatory Factor Analysis, CFA (N=410) was conducted to assess construct validity of the PVASQ. The kappa coefficients indicate a moderate to almost perfect strength of agreement between test and retest. The ICC for all scales tested for intra-rater (test-retest) reliability was good. The overall Cronbach' s alpha (N=25) is 0.912 and 0.908 for the two time points. The result of CFA (N=410) showed most items loaded strongly and correctly into corresponding factors. Only one item was eliminated. This study is the first to develop and establish the reliability and validity of the Pharmacy Value-Added Services Questionnaire instrument using the Theory of Planned Behavior as the theoretical model. The translated Malay language version of PVASQ is reliable and valid to predict Malaysian patients' intention to adopt pharmacy value-added services to collect partial medicine supply.

  5. Calibration and Validation Plan for the L2A Processor and Products of the SENTINEL-2 Mission

    NASA Astrophysics Data System (ADS)

    Main-Knorn, M.; Pflug, B.; Debaecker, V.; Louis, J.

    2015-04-01

    The Copernicus programme, is a European initiative for the implementation of information services based on observation data received from Earth Observation (EO) satellites and ground based information. In the frame of this programme, ESA is developing the Sentinel-2 optical imaging mission that will deliver optical data products designed to feed downstream services mainly related to land monitoring, emergency management and security. To ensure the highest quality of service, ESA sets up the Sentinel-2 Mission Performance Centre (MPC) in charge of the overall performance monitoring of the Sentinel-2 mission. TPZ F and DLR have teamed up in order to provide the best added-value support to the MPC for calibration and validation of the Level-2A processor (Sen2Cor) and products. This paper gives an overview over the planned L2A calibration and validation activities. Level-2A processing is applied to Top-Of-Atmosphere (TOA) Level-1C ortho-image reflectance products. Level-2A main output is the Bottom-Of-Atmosphere (BOA) corrected reflectance product. Additional outputs are an Aerosol Optical Thickness (AOT) map, a Water Vapour (WV) map and a Scene Classification (SC) map with Quality Indicators for cloud and snow probabilities. Level-2A BOA, AOT and WV outputs are calibrated and validated using ground-based data of automatic operating stations and data of in-situ campaigns. Scene classification is validated by the visual inspection of test datasets and cross-sensor comparison, supplemented by meteorological data, if available. Contributions of external in-situ campaigns would enlarge the reference dataset and enable extended validation exercise. Therefore, we are highly interested in and welcome external contributors.

  6. Self-Management Plan, Perceived Quality of Life and Medical Resource Utilization of Asthmatic Children.

    DTIC Science & Technology

    1997-05-07

    quality of life , however, has not been addressed. This descriptive, correlational study compared the perceived quality of life and number of...not adhere to a plan. Quality of life was measured using the Childhood Asthma Questionnaire, a valid and reliable quality of life measurement tool for...children of different ages. There were no significant differences between the Adherence and Non-adherence groups relative to quality of life

  7. Simulation Assessment Validation Environment (SAVE). Software User’s Manual

    DTIC Science & Technology

    2000-09-01

    requirements and decisions are made. The integration is leveraging work from other DoD organizations so that high -end results are attainable much faster than...planning through the modeling and simulation data capture and visualization process. The planners can complete the manufacturing process plan with a high ...technologies. This tool is also used to perform “ high level” factory process simulation prior to full CAD model development and help define feasible

  8. System and method for identifying, validating, weighing and characterizing moving or stationary vehicles and cargo

    DOEpatents

    Beshears, David L.; Batsell, Stephen G.; Abercrombie, Robert K.; Scudiere, Matthew B.; White, Clifford P.

    2007-12-04

    An asset identification and information infrastructure management (AI3M) device having an automated identification technology system (AIT), a Transportation Coordinators' Automated Information for Movements System II (TC-AIMS II), a weigh-in-motion system (WIM-II), and an Automated Air Load Planning system (AALPS) all in electronic communication for measuring and calculating actual asset characteristics, either statically or in-motion, and further calculating an actual load plan.

  9. Unmanned Aircraft Systems (UAS) Integration in the National Airspace System (NAS) Project - Gen-4 and Gen-5 Radio Plans

    NASA Technical Reports Server (NTRS)

    Griner, James H.

    2014-01-01

    NASA's UAS Integration in the NAS project, has partnered with Rockwell Collins to develop a concept Control and Non-Payload Communication (CNPC) system prototype radio, operating on recently allocated UAS frequency spectrum bands. This prototype radio is being used to validate initial proposed performance requirements for UAS control communications. This presentation will give an overview of the current plans for the prototype radio development.

  10. Patient-specific dosimetric endpoints based treatment plan quality control in radiotherapy.

    PubMed

    Song, Ting; Staub, David; Chen, Mingli; Lu, Weiguo; Tian, Zhen; Jia, Xun; Li, Yongbao; Zhou, Linghong; Jiang, Steve B; Gu, Xuejun

    2015-11-07

    In intensity modulated radiotherapy (IMRT), the optimal plan for each patient is specific due to unique patient anatomy. To achieve such a plan, patient-specific dosimetric goals reflecting each patient's unique anatomy should be defined and adopted in the treatment planning procedure for plan quality control. This study is to develop such a personalized treatment plan quality control tool by predicting patient-specific dosimetric endpoints (DEs). The incorporation of patient specific DEs is realized by a multi-OAR geometry-dosimetry model, capable of predicting optimal DEs based on the individual patient's geometry. The overall quality of a treatment plan is then judged with a numerical treatment plan quality indicator and characterized as optimal or suboptimal. Taking advantage of clinically available prostate volumetric modulated arc therapy (VMAT) treatment plans, we built and evaluated our proposed plan quality control tool. Using our developed tool, six of twenty evaluated plans were identified as sub-optimal plans. After plan re-optimization, these suboptimal plans achieved better OAR dose sparing without sacrificing the PTV coverage, and the dosimetric endpoints of the re-optimized plans agreed well with the model predicted values, which validate the predictability of the proposed tool. In conclusion, the developed tool is able to accurately predict optimally achievable DEs of multiple OARs, identify suboptimal plans, and guide plan optimization. It is a useful tool for achieving patient-specific treatment plan quality control.

  11. Beam commissioning and measurements validating the beam model in a new TPS that converts helical tomotherapy plans to step-and-shoot IMRT plans.

    PubMed

    Petersson, Kristoffer; Ceberg, Crister; Engström, Per; Knöös, Tommy

    2011-01-01

    A new type of treatment planning system called SHAREPLAN has been studied, which enables the transfer of treatment plans generated for helical tomotherapy delivery to plans that can be delivered on C-arm linacs. The purpose is to ensure continuous patient treatment during periods of unscheduled downtime for the TomoTherapy unit, particularly in clinics without a backup unit. The purpose of this work was to verify that the plans generated in this novel planning system are deliverable and accurate. The work consists primarily of beam commissioning, verification of the beam model, and measurements verifying that generated plans are deliverable with sufficient accuracy. The beam commissioning process involves input of general geometric properties of the modeled linac, profiles and depth dose curves for a specific photon nominal energy (6 MV), and the automated modeling of other beam properties. Some manual tuning of the beam model is required. To evaluate its accuracy, the confidence limit concept [J. Venselaar et al., "Tolerances for the accuracy of photon beam dose calculations of treatment planning systems," Radiother. Oncol. 60, 191-201 (2001)] was used, which is a method supported by ESTRO. Measurements were conducted with a 2D diode array at the commissioned linac as a final check of the beam model and to evaluate whether the generated plans were deliverable and accurate. The comparison and evaluation of calculated data points and measured data according to the method applied confirmed the accuracy of the beam model. The profiles had a confidence limit of 1.1% and the depth dose curves had a confidence limit of 1.7%, both of which were well below the tolerance limit of 2%. Plan specific QC measurements and evaluation verified that different plans generated in the TPS were deliverable with sufficient accuracy at the commissioned linac, as none of the 160 beams for the 20 different plans evaluated had a fraction of approved data points below 90%, the local clinical approval criterion for delivery QA measurements. This study is a validation of the new TPS as it verifies that the generated plans are deliverable at a commissioned linac with adequate accuracy. A thorough investigation of the treatment plan quality will require a separate study. The TPS is proving to be a useful and time-saving complement, especially for clinics having a single unit for helical delivery among its conventional linacs.

  12. A distributed planning concept for Space Station payload operations

    NASA Technical Reports Server (NTRS)

    Hagopian, Jeff; Maxwell, Theresa; Reed, Tracey

    1994-01-01

    The complex and diverse nature of the payload operations to be performed on the Space Station requires a robust and flexible planning approach. The planning approach for Space Station payload operations must support the phased development of the Space Station, as well as the geographically distributed users of the Space Station. To date, the planning approach for manned operations in space has been one of centralized planning to the n-th degree of detail. This approach, while valid for short duration flights, incurs high operations costs and is not conducive to long duration Space Station operations. The Space Station payload operations planning concept must reduce operations costs, accommodate phased station development, support distributed users, and provide flexibility. One way to meet these objectives is to distribute the planning functions across a hierarchy of payload planning organizations based on their particular needs and expertise. This paper presents a planning concept which satisfies all phases of the development of the Space Station (manned Shuttle flights, unmanned Station operations, and permanent manned operations), and the migration from centralized to distributed planning functions. Identified in this paper are the payload planning functions which can be distributed and the process by which these functions are performed.

  13. Spatial Coverage Planning and Optimization for Planetary Exploration

    NASA Technical Reports Server (NTRS)

    Gaines, Daniel M.; Estlin, Tara; Chouinard, Caroline

    2008-01-01

    We are developing onboard planning and scheduling technology to enable in situ robotic explorers, such as rovers and aerobots, to more effectively assist scientists in planetary exploration. In our current work, we are focusing on situations in which the robot is exploring large geographical features such as craters, channels or regional boundaries. In to develop valid and high quality plans, the robot must take into account a range of scientific and engineering constraints and preferences. We have developed a system that incorporates multiobjective optimization and planning allowing the robot to generate high quality mission operations plans that respect resource limitations and mission constraints while attempting to maximize science and engineering objectives. An important scientific objective for the exploration of geological features is selecting observations that spatially cover an area of interest. We have developed a metric to enable an in situ explorer to reason about and track the spatial coverage quality of a plan. We describe this technique and show how it is combined in the overall multiobjective optimization and planning algorithm.

  14. Planning Under Continuous Time and Resource Uncertainty: A Challenge for AI

    NASA Technical Reports Server (NTRS)

    Bresina, John; Dearden, Richard; Meuleau, Nicolas; Smith, David; Washington, Rich; Clancy, Daniel (Technical Monitor)

    2002-01-01

    There has been considerable work in Al on decision-theoretic planning and planning under uncertainty. Unfortunately, all of this work suffers from one or more of the following limitations: 1) it relies on very simple models of actions and time, 2) it assumes that uncertainty is manifested in discrete action outcomes, and 3) it is only practical for very small problems. For many real world problems, these assumptions fail to hold. A case in point is planning the activities for a Mars rover. For this domain none of the above assumptions are valid: 1) actions can be concurrent and have differing durations, 2) there is uncertainty concerning action durations and consumption of continuous resources like power, and 3) typical daily plans involve on the order of a hundred actions. We describe the rover problem, discuss previous work on planning under uncertainty, and present a detailed. but very small, example illustrating some of the difficulties of finding good plans.

  15. Automated Data Assimilation and Flight Planning for Multi-Platform Observation Missions

    NASA Technical Reports Server (NTRS)

    Oza, Nikunj; Morris, Robert A.; Strawa, Anthony; Kurklu, Elif; Keely, Leslie

    2008-01-01

    This is a progress report on an effort in which our goal is to demonstrate the effectiveness of automated data mining and planning for the daily management of Earth Science missions. Currently, data mining and machine learning technologies are being used by scientists at research labs for validating Earth science models. However, few if any of these advanced techniques are currently being integrated into daily mission operations. Consequently, there are significant gaps in the knowledge that can be derived from the models and data that are used each day for guiding mission activities. The result can be sub-optimal observation plans, lack of useful data, and wasteful use of resources. Recent advances in data mining, machine learning, and planning make it feasible to migrate these technologies into the daily mission planning cycle. We describe the design of a closed loop system for data acquisition, processing, and flight planning that integrates the results of machine learning into the flight planning process.

  16. California hospital networks are narrower in Marketplace than in commercial plans, but access and quality are similar.

    PubMed

    Haeder, Simon F; Weimer, David L; Mukamel, Dana B

    2015-05-01

    Do insurance plans offered through the Marketplace implemented by the State of California under the Affordable Care Act restrict consumers' access to hospitals relative to plans offered on the commercial market? And are the hospitals included in Marketplace networks of lower quality compared to those included in the commercial plans? To answer these questions, we analyzed differences in hospital networks across similar plan types offered both in the Marketplace and commercially, by region and insurer. We found that the common belief that Marketplace plans have narrower networks than their commercial counterparts appears empirically valid. However, there does not appear to be a substantive difference in geographic access as measured by the percentage of people residing in at least one hospital market area. More surprisingly, depending on the measure of hospital quality employed, the Marketplace plans have networks with comparable or even higher average quality than the networks of their commercial counterparts. Project HOPE—The People-to-People Health Foundation, Inc.

  17. Planning or something else? Examining neuropsychological predictors of Zoo Map performance.

    PubMed

    Oosterman, Joukje M; Wijers, Marijn; Kessels, Roy P C

    2013-01-01

    The Zoo Map Test of the Behavioral Assessment of the Dysexecutive Syndrome battery is often applied to measure planning ability as part of executive function. Successful performance on this test is, however, dependent on various cognitive functions, and deficient Zoo Map performance does therefore not necessarily imply selectively disrupted planning abilities. To address this important issue, we examined whether planning is still the most important predictor of Zoo Map performance in a heterogeneous sample of neurologic and psychiatric outpatients (N = 71). In addition to the Zoo Map Test, the patients completed other neuropsychological tests of planning, inhibition, processing speed, and episodic memory. Planning was the strongest predictor of the total raw score and inappropriate places visited, and no additional contribution of other cognitive scores was found. One exception to this was the total time, which was associated with processing speed. Overall, our findings indicate that the Zoo Map Test is a valid indicator of planning ability in a heterogeneous patient sample.

  18. [Planning With Nanda, Noc, Nic Taxonomies In Neurologic Rehabilitation. A clinical study].

    PubMed

    Iori, Alessandra; Foracchia, Marco; Gradellini, Cinzia

    2015-01-01

    Nursing classifications identify a specific professional responsibility, increase nursing visibility, according with nursing evolution of these last years. To evaluate care planning with NANDA taxonomy in neurologic rehabilitation context. Care plan managing with NANDA taxonomy, regarding diagnosis of constipation and impaired skin integrity, using a computerized tool for systematically observation, organized in check list. Registered data with taxonomy planning are higher in quantitative and qualitative terms. For most of patients (87%) one diagnosis has been opened, both diagnosis for 60% of them. Nursing care plan with NANDA taxonomy can be considered a valid methodology of care for neurologic patient, this since it requests a deep and complete registration of first assessment a systematically registration of each monitoring, it increases visibility of nursing job, and it underlines specific autonomy and responsibility in prevention and management of problems.

  19. Poster — Thur Eve — 30: 4D VMAT dose calculation methodology to investigate the interplay effect: experimental validation using TrueBeam Developer Mode and Gafchromic film

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Teke, T; Milette, MP; Huang, V

    2014-08-15

    The interplay effect between the tumor motion and the radiation beam modulation during a VMAT treatment delivery alters the delivered dose distribution from the planned one. This work present and validate a method to accurately calculate the dose distribution in 4D taking into account the tumor motion, the field modulation and the treatment starting phase. A QUASAR™ respiratory motion phantom was 4D scanned with motion amplitude of 3 cm and with a 3 second period. A static scan was also acquired with the lung insert and the tumor contained in it centered. A VMAT plan with a 6XFFF beam wasmore » created on the averaged CT and delivered on a Varian TrueBeam and the trajectory log file was saved. From the trajectory log file 10 VMAT plans (one for each breathing phase) and a developer mode XML file were created. For the 10 VMAT plans, the tumor motion was modeled by moving the isocentre on the static scan, the plans were re-calculated and summed in the treatment planning system. In the developer mode, the tumor motion was simulated by moving the couch dynamically during the treatment. Gafchromic films were placed in the QUASAR phantom static and irradiated using the developer mode. Different treatment starting phase were investigated (no phase shift, maximum inhalation and maximum exhalation). Calculated and measured isodose lines and profiles are in very good agreement. For each starting phase, the dose distribution exhibit significant differences but are accurately calculated with the methodology presented in this work.« less

  20. Using SysML for verification and validation planning on the Large Synoptic Survey Telescope (LSST)

    NASA Astrophysics Data System (ADS)

    Selvy, Brian M.; Claver, Charles; Angeli, George

    2014-08-01

    This paper provides an overview of the tool, language, and methodology used for Verification and Validation Planning on the Large Synoptic Survey Telescope (LSST) Project. LSST has implemented a Model Based Systems Engineering (MBSE) approach as a means of defining all systems engineering planning and definition activities that have historically been captured in paper documents. Specifically, LSST has adopted the Systems Modeling Language (SysML) standard and is utilizing a software tool called Enterprise Architect, developed by Sparx Systems. Much of the historical use of SysML has focused on the early phases of the project life cycle. Our approach is to extend the advantages of MBSE into later stages of the construction project. This paper details the methodology employed to use the tool to document the verification planning phases, including the extension of the language to accommodate the project's needs. The process includes defining the Verification Plan for each requirement, which in turn consists of a Verification Requirement, Success Criteria, Verification Method(s), Verification Level, and Verification Owner. Each Verification Method for each Requirement is defined as a Verification Activity and mapped into Verification Events, which are collections of activities that can be executed concurrently in an efficient and complementary way. Verification Event dependency and sequences are modeled using Activity Diagrams. The methodology employed also ties in to the Project Management Control System (PMCS), which utilizes Primavera P6 software, mapping each Verification Activity as a step in a planned activity. This approach leads to full traceability from initial Requirement to scheduled, costed, and resource loaded PMCS task-based activities, ensuring all requirements will be verified.

  1. Guidance on validation and qualification of processes and operations involving radiopharmaceuticals.

    PubMed

    Todde, S; Peitl, P Kolenc; Elsinga, P; Koziorowski, J; Ferrari, V; Ocak, E M; Hjelstuen, O; Patt, M; Mindt, T L; Behe, M

    2017-01-01

    Validation and qualification activities are nowadays an integral part of the day by day routine work in a radiopharmacy. This document is meant as an Appendix of Part B of the EANM "Guidelines on Good Radiopharmacy Practice (GRPP)" issued by the Radiopharmacy Committee of the EANM, covering the qualification and validation aspects related to the small-scale "in house" preparation of radiopharmaceuticals. The aim is to provide more detailed and practice-oriented guidance to those who are involved in the small-scale preparation of radiopharmaceuticals which are not intended for commercial purposes or distribution. The present guideline covers the validation and qualification activities following the well-known "validation chain", that begins with editing the general Validation Master Plan document, includes all the required documentation (e.g. User Requirement Specification, Qualification protocols, etc.), and leads to the qualification of the equipment used in the preparation and quality control of radiopharmaceuticals, until the final step of Process Validation. A specific guidance to the qualification and validation activities specifically addressed to small-scale hospital/academia radiopharmacies is here provided. Additional information, including practical examples, are also available.

  2. Validation Test Report For The CRWMS Analysis and Logistics Visually Interactive Model Calvin Version 3.0, 10074-Vtr-3.0-00

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    S. Gillespie

    2000-07-27

    This report describes the tests performed to validate the CRWMS ''Analysis and Logistics Visually Interactive'' Model (CALVIN) Version 3.0 (V3.0) computer code (STN: 10074-3.0-00). To validate the code, a series of test cases was developed in the CALVIN V3.0 Validation Test Plan (CRWMS M&O 1999a) that exercises the principal calculation models and options of CALVIN V3.0. Twenty-five test cases were developed: 18 logistics test cases and 7 cost test cases. These cases test the features of CALVIN in a sequential manner, so that the validation of each test case is used to demonstrate the accuracy of the input to subsequentmore » calculations. Where necessary, the test cases utilize reduced-size data tables to make the hand calculations used to verify the results more tractable, while still adequately testing the code's capabilities. Acceptance criteria, were established for the logistics and cost test cases in the Validation Test Plan (CRWMS M&O 1999a). The Logistics test cases were developed to test the following CALVIN calculation models: Spent nuclear fuel (SNF) and reactivity calculations; Options for altering reactor life; Adjustment of commercial SNF (CSNF) acceptance rates for fiscal year calculations and mid-year acceptance start; Fuel selection, transportation cask loading, and shipping to the Monitored Geologic Repository (MGR); Transportation cask shipping to and storage at an Interim Storage Facility (ISF); Reactor pool allocation options; and Disposal options at the MGR. Two types of cost test cases were developed: cases to validate the detailed transportation costs, and cases to validate the costs associated with the Civilian Radioactive Waste Management System (CRWMS) Management and Operating Contractor (M&O) and Regional Servicing Contractors (RSCs). For each test case, values calculated using Microsoft Excel 97 worksheets were compared to CALVIN V3.0 scenarios with the same input data and assumptions. All of the test case results compare with the CALVIN V3.0 results within the bounds of the acceptance criteria. Therefore, it is concluded that the CALVIN V3.0 calculation models and options tested in this report are validated.« less

  3. Three-Dimensional Dosimetric Validation of a Magnetic Resonance Guided Intensity Modulated Radiation Therapy System

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Rankine, Leith J., E-mail: Leith_Rankine@med.unc.edu; Department of Radiation Oncology, The University of North Carolina at Chapel Hill, Chapel Hill, North Carolina; Mein, Stewart

    Purpose: To validate the dosimetric accuracy of a commercially available magnetic resonance guided intensity modulated radiation therapy (MRgIMRT) system using a hybrid approach: 3-dimensional (3D) measurements and Monte Carlo calculations. Methods and Materials: We used PRESAGE radiochromic plastic dosimeters with remote optical computed tomography readout to perform 3D high-resolution measurements, following a novel remote dosimetry protocol. We followed the intensity modulated radiation therapy commissioning recommendations of American Association of Physicists in Medicine Task Group 119, adapted to incorporate 3D data. Preliminary tests (“AP” and “3D-Bands”) were delivered to 9.5-cm usable diameter cylindrical PRESAGE dosimeters to validate the treatment planning systemmore » (TPS) for nonmodulated deliveries; assess the sensitivity, uniformity, and rotational symmetry of the PRESAGE dosimeters; and test the robustness of the remote dosimetry protocol. Following this, 4 clinical MRgIMRT plans (“MultiTarget,” “Prostate,” “Head/Neck,” and “C-Shape”) were measured using 13-cm usable diameter PRESAGE dosimeters. For all plans, 3D-γ (3% or 3 mm global, 10% threshold) passing rates were calculated and 3D-γ maps were examined. Point doses were measured with an IBA-CC01 ionization chamber for validation of absolute dose. Finally, by use of an in-house-developed, GPU-accelerated Monte Carlo algorithm (gPENELOPE), we independently calculated dose for all 6 Task Group 119 plans and compared against the TPS. Results: For PRESAGE measurements, 3D-γ analysis yielded passing rates of 98.7%, 99.2%, 98.5%, 98.0%, 99.2%, and 90.7% for AP, 3D-Bands, MultiTarget, Prostate, Head/Neck, and C-Shape, respectively. Ion chamber measurements were within an average of 0.5% (±1.1%) from the TPS dose. Monte Carlo calculations demonstrated good agreement with the TPS, with a mean 3D-γ passing rate of 98.5% ± 1.9% using a stricter 2%/2-mm criterion. Conclusions: We have validated the dosimetric accuracy of a commercial MRgIMRT system using high-resolution 3D techniques. We have demonstrated for the first time that hybrid 3D remote dosimetry is a comprehensive and feasible approach to commissioning MRgIMRT. This may provide better sensitivity in error detection compared with standard 2-dimensional measurements and could be used when implementing complex new magnetic resonance guided radiation therapy technologies.« less

  4. 77 FR 36577 - Agency Information Collection Activities; Submission for OMB Review; Comment Request; Tax...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-06-19

    ... PERFORMS, the performance management system for the UI program. UI PERFORMS incorporates a strategic planning process of identifying priorities; ongoing collection and monitoring of valid data to measure...

  5. Space station needs, attributes and architectural options study. Final executive review

    NASA Technical Reports Server (NTRS)

    1983-01-01

    Identification and validation of missions, the benefits of manned presence in space, attributes and architectures, space station requirements, orbit selection, space station architectural options, technology selection, and program planning are addressed.

  6. VEGGIE and the VEG-01 Hardware Validation Test

    NASA Technical Reports Server (NTRS)

    Massa, Gioia

    2015-01-01

    This is a presentation to NASA HQ for a lunch-and-learn detailing the Veggie testing and results. Space Life and Physical Sciences plans to record this presentation and make it available for public display.

  7. EDMS Multi-year Validation Plan

    DOT National Transportation Integrated Search

    2001-06-01

    The Emissions and Dispersion Modeling System (EDMS) is the air quality model required for use on airport projects by the Federal Aviation Administration (FAA). This model has continued to be improved and recently has included several important enhanc...

  8. Comparison of recent major short-haul studies

    DOT National Transportation Integrated Search

    1973-04-01

    This report summarizes recent studies relating to the impact of short-haul air-transportation planning, and reviews these studies to determine their assumptions, data bases, and validity of the major analytical techniques employed. Finally, a compari...

  9. Validating the performance of vehicle classification stations.

    DOT National Transportation Integrated Search

    2012-05-01

    Vehicle classification is used in many transportation applications, e.g., infrastructure management and planning. Typical of most : developed countries, every state in the US maintains a network of vehicle classification stations to explicitly sort v...

  10. Validation of a Magnetic Resonance Imaging-based Auto-contouring Software Tool for Gross Tumour Delineation in Head and Neck Cancer Radiotherapy Planning.

    PubMed

    Doshi, T; Wilson, C; Paterson, C; Lamb, C; James, A; MacKenzie, K; Soraghan, J; Petropoulakis, L; Di Caterina, G; Grose, D

    2017-01-01

    To carry out statistical validation of a newly developed magnetic resonance imaging (MRI) auto-contouring software tool for gross tumour volume (GTV) delineation in head and neck tumours to assist in radiotherapy planning. Axial MRI baseline scans were obtained for 10 oropharyngeal and laryngeal cancer patients. GTV was present on 102 axial slices and auto-contoured using the modified fuzzy c-means clustering integrated with the level set method (FCLSM). Peer-reviewed (C-gold) manual contours were used as the reference standard to validate auto-contoured GTVs (C-auto) and mean manual contours (C-manual) from two expert clinicians (C1 and C2). Multiple geometric metrics, including the Dice similarity coefficient (DSC), were used for quantitative validation. A DSC≥0.7 was deemed acceptable. Inter- and intra-variabilities among the manual contours were also validated. The two-dimensional contours were then reconstructed in three dimensions for GTV volume calculation, comparison and three-dimensional visualisation. The mean DSC between C-gold and C-auto was 0.79. The mean DSC between C-gold and C-manual was 0.79 and that between C1 and C2 was 0.80. The average time for GTV auto-contouring per patient was 8 min (range 6-13 min; mean 45 s per axial slice) compared with 15 min (range 6-23 min; mean 88 s per axial slice) for C1. The average volume concordance between C-gold and C-auto volumes was 86.51% compared with 74.16% between C-gold and C-manual. The average volume concordance between C1 and C2 volumes was 86.82%. This newly designed MRI-based auto-contouring software tool shows initial acceptable results in GTV delineation of oropharyngeal and laryngeal tumours using FCLSM. This auto-contouring software tool may help reduce inter- and intra-variability and can assist clinical oncologists with time-consuming, complex radiotherapy planning. Copyright © 2016 The Royal College of Radiologists. Published by Elsevier Ltd. All rights reserved.

  11. Validating the Executive Personal Finance Scale with Financial Investments and Expectations in University Students.

    PubMed

    Yang, Bijou; Lester, David

    2016-06-01

    The validity of the Executive Personal Finance Scale (EPFS) was tested in a sample of 93 undergraduate students (31 men, 62 women; M age = 20.5 years, SD = 1.3, range = 18-24). Scores on the Motivation drive, Organization, and Planning subscales of this scale were associated with having a savings account, owning bank CDs, and self-estimated knowledge about financial matters, while scores on the Impulse control and Motivational drive subscales were associated with expectations for a satisfactory retirement income. The results provide support for the validity of the EPFS. © The Author(s) 2016.

  12. [Formal sample size calculation and its limited validity in animal studies of medical basic research].

    PubMed

    Mayer, B; Muche, R

    2013-01-01

    Animal studies are highly relevant for basic medical research, although their usage is discussed controversially in public. Thus, an optimal sample size for these projects should be aimed at from a biometrical point of view. Statistical sample size calculation is usually the appropriate methodology in planning medical research projects. However, required information is often not valid or only available during the course of an animal experiment. This article critically discusses the validity of formal sample size calculation for animal studies. Within the discussion, some requirements are formulated to fundamentally regulate the process of sample size determination for animal experiments.

  13. MIZMAS: Modeling the Evolution of Ice Thickness and Floe Size Distributions in the Marginal Ice Zone of the Chukchi and Beaufort Seas

    DTIC Science & Technology

    2014-09-30

    existing data sources, gathering and maintaining the data needed, and completing and reviewing the collection of information. Send comments regarding this...through downscaling future projection simulations. APPROACH To address the scientific objectives, we plan to develop, implement, and validate a...ITD and FSD at the same time. The development of MIZMAS will be based on systematic model parameterization, calibration, and validation, and data

  14. Strategic Defense Initiative Demonstration/Validation Program Environmental Assessment. Battle Management/Command and Control, and Communications (BM/C3),

    DTIC Science & Technology

    1987-08-01

    POR A ENVIOMNE. STRATEGIC DEFENSE INITRIEDNU T IATI V EI 1 0193 O RTEI ONE..()SRTGC DEFENSE INITIATV E S RATION V EO ORORNIZATION WASINZGTON DC...facilities where Demonstration/Validation activities are planned.- e Ten areas of environmental consideration are addressed: (1) air quality; (2) . water...air quality, rater quality, and hazardous vaste (63). 2.2 ELCTRONIC SYSTEMS DIVISION The Electronic Systems Division administrative offices are located

  15. Biomarkers for Early Detection of Clinically Relevant Prostate Cancer. A Multi-Institutional Validation Trial

    DTIC Science & Technology

    2016-10-01

    Study (PASS). We are in the process of evaluating these three biomarker panels in tissue, blood, and urine samples with well annotated clinical and...impacting both the initial choice of therapy and decision-making during AS. The objective of the study is to utilize analytically validated assays that...predict reclassification from Gleason 6 cancer to Gleason 7 or greater. The analysis plan was determined before specimens were selected for the study

  16. Biomarkers for Early Detection of Clinically Relevant Prostate Cancer. A Multi-Institutional Validation Trial

    DTIC Science & Technology

    2016-10-01

    Study (PASS). We are in the process of evaluating these three biomarker panels in tissue, blood, and urine samples with well annotated clinical and...choice of therapy and decision-making during AS. The objective of the study is to utilize analytically validated assays that take into account tumor...Gleason 6 cancer to Gleason 7 or greater. The analysis plan was determined before specimens were selected for the study , and included 7 breaking

  17. Cross Validation of Selection of Variables in Multiple Regression.

    DTIC Science & Technology

    1979-12-01

    55 vii CROSS VALIDATION OF SELECTION OF VARIABLES IN MULTIPLE REGRESSION I Introduction Background Long term DoD planning gcals...028545024 .31109000 BF * SS - .008700618 .0471961 Constant - .70977903 85.146786 55 had adequate predictive capabilities; the other two models (the...71ZCO F111D Control 54 73EGO FlIID Computer, General Purpose 55 73EPO FII1D Converter-Multiplexer 56 73HAO flllD Stabilizer Platform 57 73HCO F1ID

  18. Validation of Commercial Fiber Optic Components for Aerospace Environments

    NASA Technical Reports Server (NTRS)

    Ott, Melanie N.

    2005-01-01

    Full qualification for commercial photonic parts as defined by the Military specification system in the past, is not feasible. Due to changes in the photonic components industry and the Military specification system that NASA had relied upon so heavily in the past, an approach to technology validation of commercial off the shelf parts had to be devised. This approach involves knowledge of system requirements, environmental requirements and failure modes of the particular components under consideration. Synthesizing the criteria together with the major known failure modes to formulate a test plan is an effective way of establishing knowledge based "qualification". Although this does not provide the type of reliability assurance that the Military specification system did in the past, it is an approach that allows for increased risk mitigation. The information presented will introduce the audience to the technology validation approach that is currently applied at NASA for the usage of commercial-off-the-shelf (COTS) fiber optic components for space flight environments. The focus will be on how to establish technology validation criteria for commercial fiber products such that continued reliable performance is assured under the harsh environmental conditions of typical missions. The goal of this presentation is to provide the audience with an approach to formulating a COTS qualification test plan for these devices. Examples from past NASA missions will be discussed.

  19. [Development of a standardized guide for optimizing drug adherence information to be dispensed during a pharmaceutical counseling with a multiple myeloma patient: Initial validation].

    PubMed

    Favier-Archinard, Camille; Leguelinel-Blache, Géraldine; Dubois, Florent; Le Gall, Tanguy; Bourquard, Pascal; Passemard, Nadège; Tora, Sandrine; Rey, Aurélie; Rossi, Marie; Chevallier, Thierry; Cousin, Christelle; Favier, Mireille

    2018-05-01

    The safety of the community treatment with oral anticancer therapies is a strong theme of the cancer plan 2014-2019. The objective of this study was to develop a Pharmaceutical Counseling Guide to improve medication adherence in patients treated for multiple myeloma with oral anticancer therapies. A multidisciplinary professional working group selected a list of relevant medication adherence-related items that served as the framework for the design of the pharmaceutical counseling support materials in patient-accessible language. The readability, understanding and memorization of the information were validated in ten patients treated for myeloma. Twelve items were selected for treatment information (5 items), treatment planning (5 items), and adverse drug effects (2 items). A pharmacist guide, a patient guide, a medication schedule, and three self-questionnaires to evaluate medication knowledge and understanding of patients were developed. The patient test resulted in changes in these documents. This study carried out the initial validation of documents to standardize the pharmaceutical counseling for patients treated for myeloma so that it can be reproduced from one patient to another regardless of the pharmacist, by standardizing the information issued. This study needs to be completed by a final validation in myeloma patients, free from oral anticancer therapies. Copyright © 2018 Société Française du Cancer. Published by Elsevier Masson SAS. All rights reserved.

  20. Validation of a pretreatment delivery quality assurance method for the CyberKnife Synchrony system.

    PubMed

    Mastella, E; Vigorito, S; Rondi, E; Piperno, G; Ferrari, A; Strata, E; Rozza, D; Jereczek-Fossa, B A; Cattani, F

    2016-08-01

    To evaluate the geometric and dosimetric accuracies of the CyberKnife Synchrony respiratory tracking system (RTS) and to validate a method for pretreatment patient-specific delivery quality assurance (DQA). An EasyCube phantom was mounted on the ExacTrac gating phantom, which can move along the superior-inferior (SI) axis of a patient to simulate a moving target. The authors compared dynamic and static measurements. For each case, a Gafchromic EBT3 film was positioned between two slabs of the EasyCube, while a PinPoint ionization chamber was placed in the appropriate space. There were three steps to their evaluation: (1) the field size, the penumbra, and the symmetry of six secondary collimators were measured along the two main orthogonal axes. Dynamic measurements with deliberately simulated errors were also taken. (2) The delivered dose distributions (from step 1) were compared with the planned ones, using the gamma analysis method. The local gamma passing rates were evaluated using three acceptance criteria: 3% local dose difference (LDD)/3 mm, 2%LDD/2 mm, and 3%LDD/1 mm. (3) The DQA plans for six clinical patients were irradiated in different dynamic conditions, to give a total of 19 cases. The measured and planned dose distributions were evaluated with the same gamma-index criteria used in step 2 and the measured chamber doses were compared with the planned mean doses in the sensitive volume of the chamber. (1) A very slight enlargement of the field size and of the penumbra was observed in the SI direction (on average <1 mm), in line with the overall average CyberKnife system error for tracking treatments. (2) Comparison between the planned and the correctly delivered dose distributions confirmed the dosimetric accuracy of the RTS for simple plans. The multicriteria gamma analysis was able to detect the simulated errors, proving the robustness of their method of analysis. (3) All of the DQA clinical plans passed the tests, both in static and dynamic conditions. No statistically significant differences were found between static and dynamic cases, confirming the high degree of accuracy of the Synchrony RTS. The presented methods and measurements verified the mechanical and dosimetric accuracy of the Synchrony RTS. Their method confirms the fact that the RTS, if used properly, is able to treat a moving target with great precision. By combining PinPoint ion chamber, EBT3 films, and gamma evaluation of dose distributions, their DQA method robustly validated the effectiveness of CyberKnife and Synchrony system.

  1. TH-EF-BRB-06: Implementation of a Modulated-Arc Total Body Irradiation (TBI) Technique Using the RayStation Treatment Planning System

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Phillips, J; Cheung, J; Held, M

    2016-06-15

    Purpose: To develop a clinical workflow for delivering a modulated-arc total body irradiation (TBI) with RayStation scripting. This technique uses arc fields with the patient lying at floor level on a padded table and is validated through measurements taken on a custom-made TBI phantom. Methods: Treatment planning was performed for a retrospective cohort of eight patients with a diverse range of heights and body types. Each was replanned using an open-field dual arc method, with the patient in supine and prone positions on the floor of the vault. All plans were optimized using Raystation Planning 4.7.2.5 (RaySearch Laboratories, Stockholm, Sweden),more » with 200 cGy prescribed to the 95% of the body contour − 5mm. This results in an open-field beam that sweeps craniocaudally across the length of the patient. The technique is validated with measurements at 10 cm intervals in a custom-milled, 5 cm thick acrylic phantom. A centrally located CC13 ion chamber and a Mobile MOSFET (Best Medical Canada, Ottawa, ON) detector array were used to measure dose. Supine and prone arcs for each patient were consecutively delivered, and the aggregate dose at each point was compared to the planned dose calculated in the phantom. Results: The ion chamber measurements differed from the planned dose by an average of .5%, with a standard deviation of 2.1%. All measured data for the MOSFETS were within 10% of the corresponding planned dose except for two outlying points. The standard deviation of dose differences across the entire cohort was 4.0%. Most significant discrepancies occurred either in inhomogeneous regions with large gradients, or at inferior points where beam angle was steepest. Conclusion: We have confirmed that the planned dose is well matched to our measurements within 10% for this method of planning and delivery. We are currently incorporating this technique into our clinical workflow. This work is supported by RaySearch.« less

  2. Quality assurance of intensity-modulated radiation therapy.

    PubMed

    Palta, Jatinder R; Liu, Chihray; Li, Jonathan G

    2008-01-01

    The current paradigm for the quality assurance (QA) program for intensity-modulated radiation therapy (IMRT) includes QA of the treatment planning system, QA of the delivery system, and patient-specific QA. Although the IMRT treatment planning and delivery system is the same as for conventional three-dimensional conformal radiation therapy, it has more parameters to coordinate and verify. Because of complex beam intensity modulation, each IMRT field often includes many small irregular off-axis fields, resulting in isodose distributions for each IMRT plan that are more conformal than those from conventional treatment plans. Therefore, these features impose a new and more stringent set of QA requirements for IMRT planning and delivery. The generic test procedures to validate dose calculation and delivery accuracy for both treatment planning and IMRT delivery have to be customized for each type of IMRT planning and delivery strategy. The rationale for such an approach is that the overall accuracy of IMRT delivery is incumbent on the piecewise uncertainties in both the planning and delivery processes. The end user must have well-defined evaluation criteria for each element of the planning and delivery process. Such information can potentially be used to determine a priori the accuracy of IMRT planning and delivery.

  3. Nurse manager succession planning: synthesis of the evidence.

    PubMed

    Titzer, Jennifer; Phillips, Tracy; Tooley, Stephanie; Hall, Norma; Shirey, Maria

    2013-10-01

    The literature supporting nurse manager succession planning is reviewed and synthesised to discover best practice for identifying and developing future nurse managers. Healthcare succession planning practices are lacking. Nurse managers are historically selected based on clinical skills and lack formal leadership preparation. A systematic literature search appraises and summarises the current literature supporting nurse manager succession planning. Multiple reviewers were used to increase the reliability and validity of article selection and analysis. New nurse managers require months to adapt to their positions. Deliberate nurse manager succession planning should be integrated in the organisation's strategic plan and provide a proactive method for identifying and developing potential leaders. Organisations that identify and develop internal human capital can improve role transition, reduce nurse manager turnover rates and decrease replacement costs. Despite the clear benefits of succession planning, studies show that resource allocation for proactive, deliberate development of current and future nurse leaders is lacking. Additionally, systematic evaluation of succession planning is limited. Deliberate succession planning efforts and appropriate resource allocation require strategic planning and evaluation methods. Detailed evaluation methods demonstrating a positive return on investment utilising a cost-benefit analysis and empirical outcomes are necessary. © 2013 John Wiley & Sons Ltd.

  4. Predicting Patient-specific Dosimetric Benefits of Proton Therapy for Skull-base Tumors Using a Geometric Knowledge-based Method

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Hall, David C.; Trofimov, Alexei V.; Winey, Brian A.

    Purpose: To predict the organ at risk (OAR) dose levels achievable with proton beam therapy (PBT), solely based on the geometric arrangement of the target volume in relation to the OARs. A comparison with an alternative therapy yields a prediction of the patient-specific benefits offered by PBT. This could enable physicians at hospitals without proton capabilities to make a better-informed referral decision or aid patient selection in model-based clinical trials. Methods and Materials: Skull-base tumors were chosen to test the method, owing to their geometric complexity and multitude of nearby OARs. By exploiting the correlations between the dose and distance-to-targetmore » in existing PBT plans, the models were independently trained for 6 types of OARs: brainstem, cochlea, optic chiasm, optic nerve, parotid gland, and spinal cord. Once trained, the models could estimate the feasible dose–volume histogram and generalized equivalent uniform dose (gEUD) for OAR structures of new patients. The models were trained using 20 patients and validated using an additional 21 patients. Validation was achieved by comparing the predicted gEUD to that of the actual PBT plan. Results: The predicted and planned gEUD were in good agreement. Considering all OARs, the prediction error was +1.4 ± 5.1 Gy (mean ± standard deviation), and Pearson's correlation coefficient was 93%. By comparing with an intensity modulated photon treatment plan, the model could classify whether an OAR structure would experience a gain, with a sensitivity of 93% (95% confidence interval: 87%-97%) and specificity of 63% (95% confidence interval: 38%-84%). Conclusions: We trained and validated models that could quickly and accurately predict the patient-specific benefits of PBT for skull-base tumors. Similar models could be developed for other tumor sites. Such models will be useful when an estimation of the feasible benefits of PBT is desired but the experience and/or resources required for treatment planning are unavailable.« less

  5. Validation of newly developed and redesigned key indicator methods for assessment of different working conditions with physical workloads based on mixed-methods design: a study protocol

    PubMed Central

    Liebers, Falk; Brandstädt, Felix; Schust, Marianne; Serafin, Patrick; Schäfer, Andreas; Gebhardt, Hansjürgen; Hartmann, Bernd; Steinberg, Ulf

    2017-01-01

    Introduction The impact of work-related musculoskeletal disorders is considerable. The assessment of work tasks with physical workloads is crucial to estimate the work-related health risks of exposed employees. Three key indicator methods are available for risk assessment regarding manual lifting, holding and carrying of loads; manual pulling and pushing of loads; and manual handling operations. Three further KIMs for risk assessment regarding whole-body forces, awkward body postures and body movement have been developed de novo. In addition, the development of a newly drafted combined method for mixed exposures is planned. All methods will be validated regarding face validity, reliability, convergent validity, criterion validity and further aspects of utility under practical conditions. Methods and analysis As part of the joint project MEGAPHYS (multilevel risk assessment of physical workloads), a mixed-methods study is being designed for the validation of KIMs and conducted in companies of different sizes and branches in Germany. Workplaces are documented and analysed by observations, applying KIMs, interviews and assessment of environmental conditions. Furthermore, a survey among the employees at the respective workplaces takes place with standardised questionnaires, interviews and physical examinations. It is intended to include 1200 employees at 120 different workplaces. For analysis of the quality criteria, recommendations of the COSMIN checklist (COnsensus-based Standards for the selection of health Measurement INstruments) will be taken into account. Ethics and dissemination The study was planned and conducted in accordance with the German Medical Professional Code and the Declaration of Helsinki as well as the German Federal Data Protection Act. The design of the study was approved by ethics committees. We intend to publish the validated KIMs in 2018. Results will be published in peer-reviewed journals, presented at international meetings and disseminated to actual users for practical application. PMID:28827239

  6. Validation of newly developed and redesigned key indicator methods for assessment of different working conditions with physical workloads based on mixed-methods design: a study protocol.

    PubMed

    Klussmann, Andre; Liebers, Falk; Brandstädt, Felix; Schust, Marianne; Serafin, Patrick; Schäfer, Andreas; Gebhardt, Hansjürgen; Hartmann, Bernd; Steinberg, Ulf

    2017-08-21

    The impact of work-related musculoskeletal disorders is considerable. The assessment of work tasks with physical workloads is crucial to estimate the work-related health risks of exposed employees. Three key indicator methods are available for risk assessment regarding manual lifting, holding and carrying of loads; manual pulling and pushing of loads; and manual handling operations. Three further KIMs for risk assessment regarding whole-body forces, awkward body postures and body movement have been developed de novo. In addition, the development of a newly drafted combined method for mixed exposures is planned. All methods will be validated regarding face validity, reliability, convergent validity, criterion validity and further aspects of utility under practical conditions. As part of the joint project MEGAPHYS (multilevel risk assessment of physical workloads), a mixed-methods study is being designed for the validation of KIMs and conducted in companies of different sizes and branches in Germany. Workplaces are documented and analysed by observations, applying KIMs, interviews and assessment of environmental conditions. Furthermore, a survey among the employees at the respective workplaces takes place with standardised questionnaires, interviews and physical examinations. It is intended to include 1200 employees at 120 different workplaces. For analysis of the quality criteria, recommendations of the COSMIN checklist (COnsensus-based Standards for the selection of health Measurement INstruments) will be taken into account. The study was planned and conducted in accordance with the German Medical Professional Code and the Declaration of Helsinki as well as the German Federal Data Protection Act. The design of the study was approved by ethics committees. We intend to publish the validated KIMs in 2018. Results will be published in peer-reviewed journals, presented at international meetings and disseminated to actual users for practical application. © Article author(s) (or their employer(s) unless otherwise stated in the text of the article) 2017. All rights reserved. No commercial use is permitted unless otherwise expressly granted.

  7. Psychometric validation of the Italian Rehabilitation Complexity Scale-Extended version 13

    PubMed Central

    Agosti, Maurizio; Merlo, Andrea; Maini, Maurizio; Lombardi, Francesco; Tedeschi, Claudio; Benedetti, Maria Grazia; Basaglia, Nino; Contini, Mara; Nicolotti, Domenico; Brianti, Rodolfo

    2017-01-01

    In Italy, at present, a well-known problem is inhomogeneous provision of rehabilitative services, as stressed by MoH, requiring appropriate criteria and parameters to plan rehabilitation actions. According to the Italian National Rehabilitation Plan, Comorbidity, Disability and Clinical Complexity should be assessed to define the patient’s real needs. However, to date, clinical complexity is still difficult to measure with shared and validated tools. The study aims to psychometrically validate the Italian Rehabilitation Complexity Scale-Extended v13 (RCS-E v13), in order to meet the guidelines requirements. An observational multicentre prospective cohort study, involving 8 intensive rehabilitation facilities of the Emilia-Romagna Region and 1712 in-patients, [823 male (48%) and 889 female (52%), mean age 68.34 years (95% CI 67.69–69.00 years)] showing neurological, orthopaedic and cardiological problems, was carried out. The construct and concurrent validity of the RCS-E v13 was confirmed through its correlation to Barthel Index (disability) and Cumulative Illness Rating Scale (comorbidity) and appropriate admission criteria (not yet published), respectively. Furthermore, the factor analysis indicated two different components (“Basic Care or Risk—Equipment” and “Medical—Nursing Needs and Therapy Disciplines”) of the RCS-E v13. In conclusion, the Italian RCS-E v13 appears to be a useful tool to assess clinical complexity in the Italian rehab scenario case-mix and its psychometric validation may have an important clinical rehabilitation impact allowing the assessment of the rehabilitation needs considering all three dimensions (disability, comorbidity and clinical complexity) as required by the Guidelines and the inhomogeneity could be reduced. PMID:29045409

  8. System Engineering and Integration Contract for Implementation of the National Airspace System Plan. Volume 1. Sections 1.0-4.0, 6.0.

    DTIC Science & Technology

    1984-08-01

    recommendations in the report with Martin Marietta over the next few months. Appropriate followup actions will be deter- mined, and any program changes...Technical Feasibility and Validity ...... . . .. 1-6 1.3.2 Program Schedule . . . . . . ......... . .. 1-7 1.3.3 NAS Plan Cost...343.1.1 Overview 3-1 3.1.2 Findings, Risks, and Recommendations . . . . . . . . . 3-3 3.2 Program Schedule . . . . . . . . . . * . . * . *. . 3-6

  9. Communications: Critical Infrastructure and Key Resources Sector-Specific Plan as Input to the National Infrastructure Protection Plan

    DTIC Science & Technology

    2007-05-01

    Commission maintains an expert staff of engineers and statisticians to analyze this data in an attempt to reveal troublesome trends in network reliability...response, including the time for reviewing instructions, searching existing data sources, gathering and maintaining the data needed, and completing and...to a penalty for failing to comply with a collection of information if it does not display a currently valid OMB control number. 1. REPORT DATE MAY

  10. The Assessment of Military Multitasking Performance: Validation of a Dual-Task and Multitask Protocol

    DTIC Science & Technology

    2014-08-01

    Revisions based on IRR findings and rater comments Charge of Quarters (CQ) Duty Requires the subject to organize and implement a plan in order to...to evaluate test burden) and malingering are planned . Where feasible, test-retest reliability for several of the tasks is being assessed during...in either a shopping mall or hospital lobby setting (Alderman, Burgess,Knight,&Henman, 2003;Cuberos- Urbano et al., 2013; Dawson et al., 2009

  11. NEAMS SOFTWARE V&V PLAN FOR THE MARMOT SOFTWARE

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Michael R Tonks

    2014-03-01

    In order to ensure the accuracy and quality of the microstructure based materials models being developed in conjunction with MARMOT simulations, MARMOT must undergo exhaustive verification and validation. Only after this process can we confidently rely on the MARMOT code to predict the microstructure evolution within the fuel. Therefore, in this report we lay out a V&V plan for the MARMOT code, highlighting where existing data could be used and where new data is required.

  12. Development and Content Validation of Crisis Response Training Package Red Cape: Crisis Action Planning and Execution

    DTIC Science & Technology

    2007-08-01

    example, the topic of massively multiplayer online role playing games ( MMORPGs ). (A related class of first person multiplayer shooters includes...key and measurable indicators that require immediate action. They develop plans of action for these trigger points to avoid premature commitment of...recognize that the cause of the incident may be an accident or act of nature, or it may be either criminal or terrorist activity. They avoid the

  13. CMC Research at NASA Glenn in 2015: Recent Progress and Plans

    NASA Technical Reports Server (NTRS)

    Grady, Joseph E.

    2015-01-01

    As part of NASAs Aeronautical Sciences project, Glenn Research Center has developed advanced fiber and matrix constituents for a 2700F CMC for turbine engine applications. Fiber and matrix development and characterization will be reviewed. Resulting improvements in CMC mechanical properties and durability will be summarized. Plans for 2015 will be described, including development and validation of models predicting effects of the engine environment on durability of SiC/SiC composites with Environmental Barrier Coatings

  14. SciBox, an end-to-end automated science planning and commanding system

    NASA Astrophysics Data System (ADS)

    Choo, Teck H.; Murchie, Scott L.; Bedini, Peter D.; Steele, R. Josh; Skura, Joseph P.; Nguyen, Lillian; Nair, Hari; Lucks, Michael; Berman, Alice F.; McGovern, James A.; Turner, F. Scott

    2014-01-01

    SciBox is a new technology for planning and commanding science operations for Earth-orbital and planetary space missions. It has been incrementally developed since 2001 and demonstrated on several spaceflight projects. The technology has matured to the point that it is now being used to plan and command all orbital science operations for the MErcury Surface, Space ENvironment, GEochemistry, and Ranging (MESSENGER) mission to Mercury. SciBox encompasses the derivation of observing sequences from science objectives, the scheduling of those sequences, the generation of spacecraft and instrument commands, and the validation of those commands prior to uploading to the spacecraft. Although the process is automated, science and observing requirements are incorporated at each step by a series of rules and parameters to optimize observing opportunities, which are tested and validated through simulation and review. Except for limited special operations and tests, there is no manual scheduling of observations or construction of command sequences. SciBox reduces the lead time for operations planning by shortening the time-consuming coordination process, reduces cost by automating the labor-intensive processes of human-in-the-loop adjudication of observing priorities, reduces operations risk by systematically checking constraints, and maximizes science return by fully evaluating the trade space of observing opportunities to meet MESSENGER science priorities within spacecraft recorder, downlink, scheduling, and orbital-geometry constraints.

  15. Spatial distribution of nymphs of Scaphoideus titanus (Homoptera: Cicadellidae) in grapes, and evaluation of sequential sampling plans.

    PubMed

    Lessio, Federico; Alma, Alberto

    2006-04-01

    The spatial distribution of the nymphs of Scaphoideus titanus Ball (Homoptera Cicadellidae), the vector of grapevine flavescence dorée (Candidatus Phytoplasma vitis, 16Sr-V), was studied by applying Taylor's power law. Studies were conducted from 2002 to 2005, in organic and conventional vineyards of Piedmont, northern Italy. Minimum sample size and fixed precision level stop lines were calculated to develop appropriate sampling plans. Model validation was performed, using independent field data, by means of Resampling Validation of Sample Plans (RVSP) resampling software. The nymphal distribution, analyzed via Taylor's power law, was aggregated, with b = 1.49. A sample of 32 plants was adequate at low pest densities with a precision level of D0 = 0.30; but for a more accurate estimate (D0 = 0.10), the required sample size needs to be 292 plants. Green's fixed precision level stop lines seem to be more suitable for field sampling: RVSP simulations of this sampling plan showed precision levels very close to the desired levels. However, at a prefixed precision level of 0.10, sampling would become too time-consuming, whereas a precision level of 0.25 is easily achievable. How these results could influence the correct application of the compulsory control of S. titanus and Flavescence dorée in Italy is discussed.

  16. Feasibility study for early removal of HEU from CPP-651-Phase II

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Smith, C.V.; Henry, R.; Milligan, C.

    1997-09-01

    A two-phase feasibility study was initiated in late 1996 to identify a way to expedite the removal of SNM from the CPP-651 vault. The first phase of this study provided preliminary information that appeared promising, but needed additional detailed planning and evaluate to validate the concepts and conclusions. The focus of Phase 2 was to provide the validation via resource-loaded schedules and more detailed cost estimates. Section 1 describes the purpose and objectives of the Phase 2 tasks and the programmatic drivers that influence related CPP-651 high-enriched uranium (HEU) management issues. Section 2 identifies the evaluation criteria and methodology andmore » the transfer issues and barriers preventing shipment. Section 3 provides site-specific background information for the CPP-651 facility and the Idaho National Engineering and Environmental Laboratory (INEEL) and describes the development of the basic material removal schedule, the proposed base case plan for removal of SNM, and the proposed HEU material management/shipping issues and strategies. Section 4 identifies the proposed options for accelerated removal of SNM and how they were evaluated via detailed scheduling, resource histograms, and cost analysis. Section 5 summarizes principal tasks for implementing this plan and other related HEU CPP-651 management issues that require continued planning efforts to assure successful implementation of this proposed early removal strategy.« less

  17. Validating SPICES as a Screening Tool for Frailty Risks among Hospitalized Older Adults

    PubMed Central

    Aronow, Harriet Udin; Borenstein, Jeff; Haus, Flora; Braunstein, Glenn D.; Bolton, Linda Burnes

    2014-01-01

    Older patients are vulnerable to adverse hospital events related to frailty. SPICES, a common screening protocol to identify risk factors in older patients, alerts nurses to initiate care plans to reduce the probability of patient harm. However, there is little published validating the association between SPICES and measures of frailty and adverse outcomes. This paper used data from a prospective cohort study on frailty among 174 older adult inpatients to validate SPICES. Almost all patients met one or more SPICES criteria. The sum of SPICES was significantly correlated with age and other well-validated assessments for vulnerability, comorbid conditions, and depression. Individuals meeting two or more SPICES criteria had a risk of adverse hospital events three times greater than individuals with either no or one criterion. Results suggest that as a screening tool used within 24 hours of admission, SPICES is both valid and predictive of adverse events. PMID:24876954

  18. Demonstration of automated proximity and docking technologies

    NASA Astrophysics Data System (ADS)

    Anderson, Robert L.; Tsugawa, Roy K.; Bryan, Thomas C.

    An autodock was demonstrated using straightforward techniques and real sensor hardware. A simulation testbed was established and validated. The sensor design was refined with improved optical performance and image processing noise mitigation techniques, and the sensor is ready for production from off-the-shelf components. The autonomous spacecraft architecture is defined. The areas of sensors, docking hardware, propulsion, and avionics are included in the design. The Guidance Navigation and Control architecture and requirements are developed. Modular structures suitable for automated control are used. The spacecraft system manager functions including configuration, resource, and redundancy management are defined. The requirements for autonomous spacecraft executive are defined. High level decisionmaking, mission planning, and mission contingency recovery are a part of this. The next step is to do flight demonstrations. After the presentation the following question was asked. How do you define validation? There are two components to validation definition: software simulation with formal and vigorous validation, and hardware and facility performance validated with respect to software already validated against analytical profile.

  19. Gamma Knife irradiation method based on dosimetric controls to target small areas in rat brains

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Constanzo, Julie; Paquette, Benoit; Charest, Gabriel

    2015-05-15

    Purpose: Targeted and whole-brain irradiation in humans can result in significant side effects causing decreased patient quality of life. To adequately investigate structural and functional alterations after stereotactic radiosurgery, preclinical studies are needed. The purpose of this work is to establish a robust standardized method of targeted irradiation on small regions of the rat brain. Methods: Euthanized male Fischer rats were imaged in a stereotactic bed, by computed tomography (CT), to estimate positioning variations relative to the bregma skull reference point. Using a rat brain atlas and the stereotactic bregma coordinates obtained from CT images, different regions of the brainmore » were delimited and a treatment plan was generated. A single isocenter treatment plan delivering ≥100 Gy in 100% of the target volume was produced by Leksell GammaPlan using the 4 mm diameter collimator of sectors 4, 5, 7, and 8 of the Gamma Knife unit. Impact of positioning deviations of the rat brain on dose deposition was simulated by GammaPlan and validated with dosimetric measurements. Results: The authors’ results showed that 90% of the target volume received 100 ± 8 Gy and the maximum of deposited dose was 125 ± 0.7 Gy, which corresponds to an excellent relative standard deviation of 0.6%. This dose deposition calculated with GammaPlan was validated with dosimetric films resulting in a dose-profile agreement within 5%, both in X- and Z-axes. Conclusions: The authors’ results demonstrate the feasibility of standardizing the irradiation procedure of a small volume in the rat brain using a Gamma Knife.« less

  20. Anonymization of DICOM Electronic Medical Records for Radiation Therapy

    PubMed Central

    Newhauser, Wayne; Jones, Timothy; Swerdloff, Stuart; Newhauser, Warren; Cilia, Mark; Carver, Robert; Halloran, Andy; Zhang, Rui

    2014-01-01

    Electronic medical records (EMR) and treatment plans are used in research on patient outcomes and radiation effects. In many situations researchers must remove protected health information (PHI) from EMRs. The literature contains several studies describing the anonymization of generic Digital Imaging and Communication in Medicine (DICOM) files and DICOM image sets but no publications were found that discuss the anonymization of DICOM radiation therapy plans, a key component of an EMR in a cancer clinic. In addition to this we were unable to find a commercial software tool that met the minimum requirements for anonymization and preservation of data integrity for radiation therapy research. The purpose of this study was to develop a prototype software code to meet the requirements for the anonymization of radiation therapy treatment plans and to develop a way to validate that code and demonstrate that it properly anonymized treatment plans and preserved data integrity. We extended an open-source code to process all relevant PHI and to allow for the automatic anonymization of multiple EMRs. The prototype code successfully anonymized multiple treatment plans in less than 1 minute per patient. We also tested commercial optical character recognition (OCR) algorithms for the detection of burned-in text on the images, but they were unable to reliably recognize text. In addition, we developed and tested an image filtering algorithm that allowed us to isolate and redact alpha-numeric text from a test radiograph. Validation tests verified that PHI was anonymized and data integrity, such as the relationship between DICOM unique identifiers (UID) was preserved. PMID:25147130

  1. Anonymization of DICOM electronic medical records for radiation therapy.

    PubMed

    Newhauser, Wayne; Jones, Timothy; Swerdloff, Stuart; Newhauser, Warren; Cilia, Mark; Carver, Robert; Halloran, Andy; Zhang, Rui

    2014-10-01

    Electronic medical records (EMR) and treatment plans are used in research on patient outcomes and radiation effects. In many situations researchers must remove protected health information (PHI) from EMRs. The literature contains several studies describing the anonymization of generic Digital Imaging and Communication in Medicine (DICOM) files and DICOM image sets but no publications were found that discuss the anonymization of DICOM radiation therapy plans, a key component of an EMR in a cancer clinic. In addition to this we were unable to find a commercial software tool that met the minimum requirements for anonymization and preservation of data integrity for radiation therapy research. The purpose of this study was to develop a prototype software code to meet the requirements for the anonymization of radiation therapy treatment plans and to develop a way to validate that code and demonstrate that it properly anonymized treatment plans and preserved data integrity. We extended an open-source code to process all relevant PHI and to allow for the automatic anonymization of multiple EMRs. The prototype code successfully anonymized multiple treatment plans in less than 1min/patient. We also tested commercial optical character recognition (OCR) algorithms for the detection of burned-in text on the images, but they were unable to reliably recognize text. In addition, we developed and tested an image filtering algorithm that allowed us to isolate and redact alpha-numeric text from a test radiograph. Validation tests verified that PHI was anonymized and data integrity, such as the relationship between DICOM unique identifiers (UID) was preserved. Copyright © 2014 Elsevier Ltd. All rights reserved.

  2. SU-F-T-156: Monte Carlo Simulation Using TOPAS for Synchrotron Based Proton Discrete Spot Scanning System

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Moskvin, V; Pirlepesov, F; Tsiamas, P

    Purpose: This study provides an overview of the design and commissioning of the Monte Carlo (MC) model of the spot-scanning proton therapy nozzle and its implementation for the patient plan simulation. Methods: The Hitachi PROBEAT V scanning nozzle was simulated based on vendor specifications using the TOPAS extension of Geant4 code. FLUKA MC simulation was also utilized to provide supporting data for the main simulation. Validation of the MC model was performed using vendor provided data and measurements collected during acceptance/commissioning of the proton therapy machine. Actual patient plans using CT based treatment geometry were simulated and compared to themore » dose distributions produced by the treatment planning system (Varian Eclipse 13.6), and patient quality assurance measurements. In-house MATLAB scripts are used for converting DICOM data into TOPAS input files. Results: Comparison analysis of integrated depth doses (IDDs), therapeutic ranges (R90), and spot shape/sizes at different distances from the isocenter, indicate good agreement between MC and measurements. R90 agreement is within 0.15 mm across all energy tunes. IDDs and spot shapes/sizes differences are within statistical error of simulation (less than 1.5%). The MC simulated data, validated with physical measurements, were used for the commissioning of the treatment planning system. Patient geometry simulations were conducted based on the Eclipse produced DICOM plans. Conclusion: The treatment nozzle and standard option beam model were implemented in the TOPAS framework to simulate a highly conformal discrete spot-scanning proton beam system.« less

  3. Cross-cultural validity of the theory of planned behavior for predicting healthy food choice in secondary school students of Inner Mongolia.

    PubMed

    Shimazaki, Takashi; Bao, Hugejiletu; Deli, Geer; Uechi, Hiroaki; Lee, Ying-Hua; Miura, Kayo; Takenaka, Koji

    2017-11-01

    Unhealthy eating behavior is a serious health concern among secondary school students in Inner Mongolia. To predict their healthy food choices and devise methods of correcting unhealthy choices, we sought to confirm the cross-cultural validity of the theory of planned behavior among Inner Mongolian students. A cross-sectional study, conducted between November and December 2014. Overall, 3047 students were enrolled. We devised a questionnaire based on the theory of planned behavior to measure its components (intentions, attitudes, subjective norms, and perceived behavioral control) in relation to healthy food choices; we also assessed their current engagement in healthy food choices. A principal component analysis revealed high contribution rates for the components (69.32%-88.77%). A confirmatory factor analysis indicated that the components of the questionnaire had adequate model fit (goodness of fit index=0.997, adjusted goodness of fit index=0.984, comparative fit index=0.998, and root mean square error of approximation=0.049). Notably, data from participants within the suburbs did not support the theory of planned behavior construction. Several paths did not predict the hypothesis variables. However, attitudes toward healthy food choices strongly predicted behavioral intention (path coefficients 0.49-0.77, p<0.01), regardless of demographic characteristics. Our results support that the theory of planned behavior can apply to secondary school students in urban areas. Furthermore, attitudes towards healthy food choices were the best predictor of behavioral intentions to engage in such choices in Inner Mongolian students. Copyright © 2017 Diabetes India. Published by Elsevier Ltd. All rights reserved.

  4. Validating Domains of Patient Contextual Factors Essential to Preventing Contextual Errors: A Qualitative Study Conducted at Chicago Area Veterans Health Administration Sites.

    PubMed

    Binns-Calvey, Amy E; Malhiot, Alex; Kostovich, Carol T; LaVela, Sherri L; Stroupe, Kevin; Gerber, Ben S; Burkhart, Lisa; Weiner, Saul J; Weaver, Frances M

    2017-09-01

    "Patient context" indicates patient circumstances and characteristics or states that are essential to address when planning patient care. Specific patient "contextual factors," if overlooked, result in an inappropriate plan of care, a medical error termed a "contextual error." The myriad contextual factors that constitute patient context have been grouped into broad domains to create a taxonomy of challenges to consider when planning care. This study sought to validate a previously identified list of contextual domains. This qualitative study used directed content analysis. In 2014, 19 Department of Veterans Affairs (VA) providers (84% female) and 49 patients (86% male) from two VA medical centers and four outpatient clinics in the Chicago area participated in semistructured interviews and focus groups. Topics included patient-specific, community, and resource-related factors that affect patients' abilities to manage their care. Transcripts were analyzed with a previously identified list of contextual domains as a framework. Analysis of responses revealed that patients and providers identified the same 10 domains previously published, plus 3 additional ones. Based on comments made by patients and providers, the authors created a revised list of 12 domains from themes that emerged. Six pertain to patient circumstances such as access to care and financial situation, and 6 to patient characteristics/states including skills, abilities, and knowledge. Contextual factors in patients' lives may be essential to address for effective care planning. The rubric developed can serve as a "contextual differential" for clinicians to consider when addressing challenges patients face when planning their care.

  5. Data-driven traffic impact assessment tool for work zones.

    DOT National Transportation Integrated Search

    2017-03-01

    Traditionally, traffic impacts of work zones have been assessed using planning software such as Quick Zone, custom spreadsheets, and others. These software programs generate delay, queuing, and other mobility measures but are difficult to validate du...

  6. Input Range Testing for the General Mission Analysis Tool (GMAT)

    NASA Technical Reports Server (NTRS)

    Hughes, Steven P.

    2007-01-01

    This document contains a test plan for testing input values to the General Mission Analysis Tool (GMAT). The plan includes four primary types of information, which rigorously define all tests that should be performed to validate that GMAT will accept allowable inputs and deny disallowed inputs. The first is a complete list of all allowed object fields in GMAT. The second type of information, is test input to be attempted for each field. The third type of information is allowable input values for all objects fields in GMAT. The final piece of information is how GMAT should respond to both valid and invalid information. It is VERY important to note that the tests below must be performed for both the Graphical User Interface and the script!! The examples are illustrated using a scripting perspective, because it is simpler to write up. However, the test must be performed for both interfaces to GMAT.

  7. The Close-Up Imager Onboard the ESA ExoMars Rover: Objectives, Description, Operations, and Science Validation Activities.

    PubMed

    Josset, Jean-Luc; Westall, Frances; Hofmann, Beda A; Spray, John; Cockell, Charles; Kempe, Stephan; Griffiths, Andrew D; De Sanctis, Maria Cristina; Colangeli, Luigi; Koschny, Detlef; Föllmi, Karl; Verrecchia, Eric; Diamond, Larryn; Josset, Marie; Javaux, Emmanuelle J; Esposito, Francesca; Gunn, Matthew; Souchon-Leitner, Audrey L; Bontognali, Tomaso R R; Korablev, Oleg; Erkman, Suren; Paar, Gerhard; Ulamec, Stephan; Foucher, Frédéric; Martin, Philippe; Verhaeghe, Antoine; Tanevski, Mitko; Vago, Jorge L

    The Close-Up Imager (CLUPI) onboard the ESA ExoMars Rover is a powerful high-resolution color camera specifically designed for close-up observations. Its accommodation on the movable drill allows multiple positioning. The science objectives of the instrument are geological characterization of rocks in terms of texture, structure, and color and the search for potential morphological biosignatures. We present the CLUPI science objectives, performance, and technical description, followed by a description of the instrument's planned operations strategy during the mission on Mars. CLUPI will contribute to the rover mission by surveying the geological environment, acquiring close-up images of outcrops, observing the drilling area, inspecting the top portion of the drill borehole (and deposited fines), monitoring drilling operations, and imaging samples collected by the drill. A status of the current development and planned science validation activities is also given. Key Words: Mars-Biosignatures-Planetary Instrumentation. Astrobiology 17, 595-611.

  8. Clerkship maturity: does the idea of training clinical skills work?

    PubMed

    Stosch, Christoph; Joachim, Alexander; Ascher, Johannes

    2011-01-01

    With the reformed curriculum "4C", the Medical Faculty of the University of Cologne has started to systematically plan practical skills training, for which Clerkship Maturity is the first step. The key guidelines along which the curriculum was development were developed by experts. This approach has now been validated. Both students and teachers were asked to fill in a questionnaire regarding preclinical practical skills training to confirm the concept of Clerkship Maturity. The Cologne training program Clerkship Maturity can be validated empirically overall through the activities of the students awaiting the clerkship framework and through the evaluation by the medical staff providing the training. The subjective ratings of the advantages of the training by the students leave room for improvement. Apart from minor improvements to the program, the most likely solution providing sustainable results will involve an over-regional strategy for establishing skills training planned as part of the curriculum.

  9. Traverse Planning Experiments for Future Planetary Surface Exploration

    NASA Technical Reports Server (NTRS)

    Hoffman, Stephen J.; Voels, Stephen A.; Mueller, Robert P.; Lee, Pascal C.

    2012-01-01

    The purpose of the investigation is to evaluate methodology and data requirements for remotely-assisted robotic traverse of extraterrestrial planetary surface to support human exploration program, assess opportunities for in-transit science operations, and validate landing site survey and selection techniques during planetary surface exploration mission analog demonstration at Haughton Crater on Devon Island, Nunavut, Canada. Additionally, 1) identify quality of remote observation data sets (i.e., surface imagery from orbit) required for effective pre-traverse route planning and determine if surface level data (i.e., onboard robotic imagery or other sensor data) is required for a successful traverse, and if additional surface level data can improve traverse efficiency or probability of success (TRPF Experiment). 2) Evaluate feasibility and techniques for conducting opportunistic science investigations during this type of traverse. (OSP Experiment). 3) Assess utility of remotely-assisted robotic vehicle for landing site validation survey. (LSV Experiment).

  10. The Effectiveness of Guided Inquiry-based Learning Material on Students’ Science Literacy Skills

    NASA Astrophysics Data System (ADS)

    Aulia, E. V.; Poedjiastoeti, S.; Agustini, R.

    2018-01-01

    The purpose of this research is to describe the effectiveness of guided inquiry-based learning material to improve students’ science literacy skills on solubility and solubility product concepts. This study used Research and Development (R&D) design and was implemented to the 11th graders of Muhammadiyah 4 Senior High School Surabaya in 2016/2017 academic year with one group pre-test and post-test design. The data collection techniques used were validation, observation, test, and questionnaire. The results of this research showed that the students’ science literacy skills are different after implementation of guided inquiry-based learning material. The guided inquiry-based learning material is effective to improve students’ science literacy skills on solubility and solubility product concepts by getting N-gain score with medium and high category. This improvement caused by the developed learning material such as lesson plan, student worksheet, and science literacy skill tests were categorized as valid and very valid. In addition, each of the learning phases in lesson plan has been well implemented. Therefore, it can be concluded that the guided inquiry-based learning material are effective to improve students’ science literacy skills on solubility and solubility product concepts in senior high school.

  11. A Machine Learning Framework for Plan Payment Risk Adjustment.

    PubMed

    Rose, Sherri

    2016-12-01

    To introduce cross-validation and a nonparametric machine learning framework for plan payment risk adjustment and then assess whether they have the potential to improve risk adjustment. 2011-2012 Truven MarketScan database. We compare the performance of multiple statistical approaches within a broad machine learning framework for estimation of risk adjustment formulas. Total annual expenditure was predicted using age, sex, geography, inpatient diagnoses, and hierarchical condition category variables. The methods included regression, penalized regression, decision trees, neural networks, and an ensemble super learner, all in concert with screening algorithms that reduce the set of variables considered. The performance of these methods was compared based on cross-validated R 2 . Our results indicate that a simplified risk adjustment formula selected via this nonparametric framework maintains much of the efficiency of a traditional larger formula. The ensemble approach also outperformed classical regression and all other algorithms studied. The implementation of cross-validated machine learning techniques provides novel insight into risk adjustment estimation, possibly allowing for a simplified formula, thereby reducing incentives for increased coding intensity as well as the ability of insurers to "game" the system with aggressive diagnostic upcoding. © Health Research and Educational Trust.

  12. SEA in local land use planning - first experience in the Alpine States

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Jiricka, Alexandra; Proebstl, Ulrike

    2008-05-15

    In the Alpine area, planning decisions can result in far-reaching consequences because of the high sensitivity of the Alpine ecosystems. This article is based on two hypotheses: (1) The Alpine states/regions were aware of their sensitive environment and therefore recognized the necessity of introducing a comparable instrument to assess local land use planning. (2) By introducing this differentiated assessment tool, namely SEA, an increase in costs may be the consequence. However, better and more transparent planning can contribute to the enhancement of planning standards. To reveal the validity of these assumptions the legal implementation in the Alpine countries Austria, Germany,more » Italy and France was examined as well as first practical experience resulting from the determined procedures. The results of the implementation process in the four states were compared and discussed on the basis of selected process steps of SEA.« less

  13. Evaluation of nonmetallic thermal protection materials for the manned space shuttle. Volume 1, task 1: Assessment of technical risks associated with utilization of nonmetallic thermal protection system

    NASA Technical Reports Server (NTRS)

    Wilkinson, W. H.; Kirkhart, F. P.; Kistler, C. W.; Duckworth, W. H.; Ungar, E. W.; Foster, E. L.

    1970-01-01

    Technical problems of design and flight qualification of the proposed classes of surface insulation materials and leading edge materials were reviewed. A screening test plan, a preliminary design data test plan and a design data test plan were outlined. This program defined the apparent critical differences between the surface insulators and the leading edge materials, structuring specialized screening test plans for each of these two classes of materials. Unique testing techniques were shown to be important in evaluating the structural interaction aspects of the surface insulators and a separate task was defined to validate the test plan. In addition, a compilation was made of available information on proposed material (including metallic TPS), previous shuttle programs, pertinent test procedures, and other national programs of merit. This material was collected and summarized in an informally structured workbook.

  14. Design and architecture of the Mars relay network planning and analysis framework

    NASA Technical Reports Server (NTRS)

    Cheung, K. M.; Lee, C. H.

    2002-01-01

    In this paper we describe the design and architecture of the Mars Network planning and analysis framework that supports generation and validation of efficient planning and scheduling strategy. The goals are to minimize the transmitting time, minimize the delaying time, and/or maximize the network throughputs. The proposed framework would require (1) a client-server architecture to support interactive, batch, WEB, and distributed analysis and planning applications for the relay network analysis scheme, (2) a high-fidelity modeling and simulation environment that expresses link capabilities between spacecraft to spacecraft and spacecraft to Earth stations as time-varying resources, and spacecraft activities, link priority, Solar System dynamic events, the laws of orbital mechanics, and other limiting factors as spacecraft power and thermal constraints, (3) an optimization methodology that casts the resource and constraint models into a standard linear and nonlinear constrained optimization problem that lends itself to commercial off-the-shelf (COTS)planning and scheduling algorithms.

  15. Verification and Validation of Flight-Critical Systems

    NASA Technical Reports Server (NTRS)

    Brat, Guillaume

    2010-01-01

    For the first time in many years, the NASA budget presented to congress calls for a focused effort on the verification and validation (V&V) of complex systems. This is mostly motivated by the results of the VVFCS (V&V of Flight-Critical Systems) study, which should materialize as a a concrete effort under the Aviation Safety program. This talk will present the results of the study, from requirements coming out of discussions with the FAA and the Joint Planning and Development Office (JPDO) to technical plan addressing the issue, and its proposed current and future V&V research agenda, which will be addressed by NASA Ames, Langley, and Dryden as well as external partners through NASA Research Announcements (NRA) calls. This agenda calls for pushing V&V earlier in the life cycle and take advantage of formal methods to increase safety and reduce cost of V&V. I will present the on-going research work (especially the four main technical areas: Safety Assurance, Distributed Systems, Authority and Autonomy, and Software-Intensive Systems), possible extensions, and how VVFCS plans on grounding the research in realistic examples, including an intended V&V test-bench based on an Integrated Modular Avionics (IMA) architecture and hosted by Dryden.

  16. Dark matter search in a Beam-Dump eXperiment (BDX) at Jefferson Lab: an update on PR12-16-001

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Battaglieri, M.

    This document is an update to the proposal PR12-16-001 Dark matter search in a Beam-Dump eXperiment (BDX) at Jefferson Lab submitted to JLab-PAC44 in 2016 reporting progress in addressing questions raised regarding the beam-on backgrounds. The concerns are addressed by adopting a new simulation tool, FLUKA, and planning measurements of muon fluxes from the dump with its existing shielding around the dump. First, we have implemented the detailed BDX experimental geometry into a FLUKA simulation, in consultation with experts from the JLab Radiation Control Group. The FLUKA simulation has been compared directly to our GEANT4 simulations and shown to agreemore » in regions of validity. The FLUKA interaction package, with a tuned set of biasing weights, is naturally able to generate reliable particle distributions with very small probabilities and therefore predict rates at the detector location beyond the planned shielding around the beam dump. Second, we have developed a plan to conduct measurements of the muon ux from the Hall-A dump in its current configuration to validate our simulations.« less

  17. X-43 Hypersonic Vehicle Technology Development

    NASA Technical Reports Server (NTRS)

    Voland, Randall T.; Huebner, Lawrence D.; McClinton, Charles R.

    2005-01-01

    NASA recently completed two major programs in Hypersonics: Hyper-X, with the record-breaking flights of the X-43A, and the Next Generation Launch Technology (NGLT) Program. The X-43A flights, the culmination of the Hyper-X Program, were the first-ever examples of a scramjet engine propelling a hypersonic vehicle and provided unique, convincing, detailed flight data required to validate the design tools needed for design and development of future operational hypersonic airbreathing vehicles. Concurrent with Hyper-X, NASA's NGLT Program focused on technologies needed for future revolutionary launch vehicles. The NGLT was "competed" by NASA in response to the President s redirection of the agency to space exploration, after making significant progress towards maturing technologies required to enable airbreathing hypersonic launch vehicles. NGLT quantified the benefits, identified technology needs, developed airframe and propulsion technology, chartered a broad University base, and developed detailed plans to mature and validate hypersonic airbreathing technology for space access. NASA is currently in the process of defining plans for a new Hypersonic Technology Program. Details of that plan are not currently available. This paper highlights results from the successful Mach 7 and 10 flights of the X-43A, and the current state of hypersonic technology.

  18. Hospital-based expert model for health technology procurement planning in hospitals.

    PubMed

    Miniati, R; Cecconi, G; Frosini, F; Dori, F; Regolini, J; Iadanza, E; Biffi Gentili, G

    2014-01-01

    Although in the last years technology innovation in healthcare brought big improvements in care level and patient quality of life, hospital complexity and management cost became higher. For this reason, necessity of planning for medical equipment procurement within hospitals is getting more and more important in order to sustainable provide appropriate technology for both routine activity and innovative procedures. In order to support hospital decision makers for technology procurement planning, an expert model was designed as reported in the following paper. It combines the most widely used approaches for technology evaluation by taking into consideration Health Technology Assessment (HTA) and Medical Equipment Replacement Model (MERM). The designing phases include a first definition of prioritization algorithms, then the weighting process through experts' interviews and a final step for the model validation that included both statistical testing and comparison with real decisions. In conclusion, the designed model was able to provide a semi-automated tool that through the use of multidisciplinary information is able to prioritize different requests of technology acquisition in hospitals. Validation outcomes improved the model accuracy and created different "user profiles" according to the specific needs of decision makers.

  19. V&V Plan for FPGA-based ESF-CCS Using System Engineering Approach.

    NASA Astrophysics Data System (ADS)

    Maerani, Restu; Mayaka, Joyce; El Akrat, Mohamed; Cheon, Jung Jae

    2018-02-01

    Instrumentation and Control (I&C) systems play an important role in maintaining the safety of Nuclear Power Plant (NPP) operation. However, most current I&C safety systems are based on Programmable Logic Controller (PLC) hardware, which is difficult to verify and validate, and is susceptible to software common cause failure. Therefore, a plan for the replacement of the PLC-based safety systems, such as the Engineered Safety Feature - Component Control System (ESF-CCS), with Field Programmable Gate Arrays (FPGA) is needed. By using a systems engineering approach, which ensures traceability in every phase of the life cycle, from system requirements, design implementation to verification and validation, the system development is guaranteed to be in line with the regulatory requirements. The Verification process will ensure that the customer and stakeholder’s needs are satisfied in a high quality, trustworthy, cost efficient and schedule compliant manner throughout a system’s entire life cycle. The benefit of the V&V plan is to ensure that the FPGA based ESF-CCS is correctly built, and to ensure that the measurement of performance indicators has positive feedback that “do we do the right thing” during the re-engineering process of the FPGA based ESF-CCS.

  20. Measuring infrastructure: A key step in program evaluation and planning

    PubMed Central

    Schmitt, Carol L.; Glasgow, LaShawn; Lavinghouze, S. Rene; Rieker, Patricia P.; Fulmer, Erika; McAleer, Kelly; Rogers, Todd

    2016-01-01

    State tobacco prevention and control programs (TCPs) require a fully functioning infrastructure to respond effectively to the Surgeon General’s call for accelerating the national reduction in tobacco use. The literature describes common elements of infrastructure; however, a lack of valid and reliable measures has made it difficult for program planners to monitor relevant infrastructure indicators and address observed deficiencies, or for evaluators to determine the association among infrastructure, program efforts, and program outcomes. The Component Model of Infrastructure (CMI) is a comprehensive, evidence-based framework that facilitates TCP program planning efforts to develop and maintain their infrastructure. Measures of CMI components were needed to evaluate the model’s utility and predictive capability for assessing infrastructure. This paper describes the development of CMI measures and results of a pilot test with nine state TCP managers. Pilot test findings indicate that the tool has good face validity and is clear and easy to follow. The CMI tool yields data that can enhance public health efforts in a funding-constrained environment and provides insight into program sustainability. Ultimately, the CMI measurement tool could facilitate better evaluation and program planning across public health programs. PMID:27037655

  1. Measuring infrastructure: A key step in program evaluation and planning.

    PubMed

    Schmitt, Carol L; Glasgow, LaShawn; Lavinghouze, S Rene; Rieker, Patricia P; Fulmer, Erika; McAleer, Kelly; Rogers, Todd

    2016-06-01

    State tobacco prevention and control programs (TCPs) require a fully functioning infrastructure to respond effectively to the Surgeon General's call for accelerating the national reduction in tobacco use. The literature describes common elements of infrastructure; however, a lack of valid and reliable measures has made it difficult for program planners to monitor relevant infrastructure indicators and address observed deficiencies, or for evaluators to determine the association among infrastructure, program efforts, and program outcomes. The Component Model of Infrastructure (CMI) is a comprehensive, evidence-based framework that facilitates TCP program planning efforts to develop and maintain their infrastructure. Measures of CMI components were needed to evaluate the model's utility and predictive capability for assessing infrastructure. This paper describes the development of CMI measures and results of a pilot test with nine state TCP managers. Pilot test findings indicate that the tool has good face validity and is clear and easy to follow. The CMI tool yields data that can enhance public health efforts in a funding-constrained environment and provides insight into program sustainability. Ultimately, the CMI measurement tool could facilitate better evaluation and program planning across public health programs. Copyright © 2016 Elsevier Ltd. All rights reserved.

  2. An Approach in Radiation Therapy Treatment Planning: A Fast, GPU-Based Monte Carlo Method.

    PubMed

    Karbalaee, Mojtaba; Shahbazi-Gahrouei, Daryoush; Tavakoli, Mohammad B

    2017-01-01

    An accurate and fast radiation dose calculation is essential for successful radiation radiotherapy. The aim of this study was to implement a new graphic processing unit (GPU) based radiation therapy treatment planning for accurate and fast dose calculation in radiotherapy centers. A program was written for parallel running based on GPU. The code validation was performed by EGSnrc/DOSXYZnrc. Moreover, a semi-automatic, rotary, asymmetric phantom was designed and produced using a bone, the lung, and the soft tissue equivalent materials. All measurements were performed using a Mapcheck dosimeter. The accuracy of the code was validated using the experimental data, which was obtained from the anthropomorphic phantom as the gold standard. The findings showed that, compared with those of DOSXYZnrc in the virtual phantom and for most of the voxels (>95%), <3% dose-difference or 3 mm distance-to-agreement (DTA) was found. Moreover, considering the anthropomorphic phantom, compared to the Mapcheck dose measurements, <5% dose-difference or 5 mm DTA was observed. Fast calculation speed and high accuracy of GPU-based Monte Carlo method in dose calculation may be useful in routine radiation therapy centers as the core and main component of a treatment planning verification system.

  3. Development of a microlesson in teaching energy levels of atoms

    NASA Astrophysics Data System (ADS)

    Rodriguez, Cherilyn A.; Buan, Amelia T.

    2018-01-01

    Energy levels of atoms is one of the difficult topics in understanding atomic structure of matter. It appears tobe abstract, theoretical and needs visual representation and images. Hence, in this study a microlesson in teaching the high school chemistry concept on the energy levels of atoms is developed and validated. The researchers utilized backward curriculum design in planning the microlesson to meet the standards of the science K-12 curriculum. The planning process of the microlesson involved a) Identifying the learning competencies in K-12 science curriculum b) write learning objectives c) planning of assessment tools d) making a storyboard e) designing the microlesson and validate and revise the microlesson. The microlesson made use of varied resources in the internet from which the students accessed and collected information about energy levels of atoms. Working in groups, the students synthesized the information on how and why fireworks produce various colors of light through a post card. Findings of the study showed that there was an increase of achievement in learning the content and the students were highly motivated to learn chemistry. Furthermore, the students perceived that the microlesson helped them to understand the chemistry concept through the use of appropriate multimedia activities.

  4. Space Weather Model Testing And Validation At The Community Coordinated Modeling Center

    NASA Astrophysics Data System (ADS)

    Hesse, M.; Kuznetsova, M.; Rastaetter, L.; Falasca, A.; Keller, K.; Reitan, P.

    The Community Coordinated Modeling Center (CCMC) is a multi-agency partner- ship aimed at the creation of next generation space weather models. The goal of the CCMC is to undertake the research and developmental work necessary to substantially increase the present-day modeling capability for space weather purposes, and to pro- vide models for transition to the rapid prototyping centers at the space weather forecast centers. This goal requires close collaborations with and substantial involvement of the research community. The physical regions to be addressed by CCMC-related activities range from the solar atmosphere to the Earth's upper atmosphere. The CCMC is an integral part of NASA's Living With aStar initiative, of the National Space Weather Program Implementation Plan, and of the Department of Defense Space Weather Tran- sition Plan. CCMC includes a facility at NASA Goddard Space Flight Center, as well as distributed computing facilities provided by the Air Force. CCMC also provides, to the research community, access to state-of-the-art space research models. In this paper we will provide updates on CCMC status, on current plans, research and devel- opment accomplishments and goals, and on the model testing and validation process undertaken as part of the CCMC mandate.

  5. Helium ions at the heidelberg ion beam therapy center: comparisons between FLUKA Monte Carlo code predictions and dosimetric measurements

    NASA Astrophysics Data System (ADS)

    Tessonnier, T.; Mairani, A.; Brons, S.; Sala, P.; Cerutti, F.; Ferrari, A.; Haberer, T.; Debus, J.; Parodi, K.

    2017-08-01

    In the field of particle therapy helium ion beams could offer an alternative for radiotherapy treatments, owing to their interesting physical and biological properties intermediate between protons and carbon ions. We present in this work the comparisons and validations of the Monte Carlo FLUKA code against in-depth dosimetric measurements acquired at the Heidelberg Ion Beam Therapy Center (HIT). Depth dose distributions in water with and without ripple filter, lateral profiles at different depths in water and a spread-out Bragg peak were investigated. After experimentally-driven tuning of the less known initial beam characteristics in vacuum (beam lateral size and momentum spread) and simulation parameters (water ionization potential), comparisons of depth dose distributions were performed between simulations and measurements, which showed overall good agreement with range differences below 0.1 mm and dose-weighted average dose-differences below 2.3% throughout the entire energy range. Comparisons of lateral dose profiles showed differences in full-width-half-maximum lower than 0.7 mm. Measurements of the spread-out Bragg peak indicated differences with simulations below 1% in the high dose regions and 3% in all other regions, with a range difference less than 0.5 mm. Despite the promising results, some discrepancies between simulations and measurements were observed, particularly at high energies. These differences were attributed to an underestimation of dose contributions from secondary particles at large angles, as seen in a triple Gaussian parametrization of the lateral profiles along the depth. However, the results allowed us to validate FLUKA simulations against measurements, confirming its suitability for 4He ion beam modeling in preparation of clinical establishment at HIT. Future activities building on this work will include treatment plan comparisons using validated biological models between proton and helium ions, either within a Monte Carlo treatment planning engine based on the same FLUKA code, or an independent analytical planning system fed with a validated database of inputs calculated with FLUKA.

  6. Helium ions at the heidelberg ion beam therapy center: comparisons between FLUKA Monte Carlo code predictions and dosimetric measurements.

    PubMed

    Tessonnier, T; Mairani, A; Brons, S; Sala, P; Cerutti, F; Ferrari, A; Haberer, T; Debus, J; Parodi, K

    2017-08-01

    In the field of particle therapy helium ion beams could offer an alternative for radiotherapy treatments, owing to their interesting physical and biological properties intermediate between protons and carbon ions. We present in this work the comparisons and validations of the Monte Carlo FLUKA code against in-depth dosimetric measurements acquired at the Heidelberg Ion Beam Therapy Center (HIT). Depth dose distributions in water with and without ripple filter, lateral profiles at different depths in water and a spread-out Bragg peak were investigated. After experimentally-driven tuning of the less known initial beam characteristics in vacuum (beam lateral size and momentum spread) and simulation parameters (water ionization potential), comparisons of depth dose distributions were performed between simulations and measurements, which showed overall good agreement with range differences below 0.1 mm and dose-weighted average dose-differences below 2.3% throughout the entire energy range. Comparisons of lateral dose profiles showed differences in full-width-half-maximum lower than 0.7 mm. Measurements of the spread-out Bragg peak indicated differences with simulations below 1% in the high dose regions and 3% in all other regions, with a range difference less than 0.5 mm. Despite the promising results, some discrepancies between simulations and measurements were observed, particularly at high energies. These differences were attributed to an underestimation of dose contributions from secondary particles at large angles, as seen in a triple Gaussian parametrization of the lateral profiles along the depth. However, the results allowed us to validate FLUKA simulations against measurements, confirming its suitability for 4 He ion beam modeling in preparation of clinical establishment at HIT. Future activities building on this work will include treatment plan comparisons using validated biological models between proton and helium ions, either within a Monte Carlo treatment planning engine based on the same FLUKA code, or an independent analytical planning system fed with a validated database of inputs calculated with FLUKA.

  7. SU-G-BRC-13: Model Based Classification for Optimal Position Selection for Left-Sided Breast Radiotherapy: Free Breathing, DIBH, Or Prone

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Lin, H; Liu, T; Xu, X

    Purpose: There are clinical decision challenges to select optimal treatment positions for left-sided breast cancer patients—supine free breathing (FB), supine Deep Inspiration Breath Hold (DIBH) and prone free breathing (prone). Physicians often make the decision based on experiences and trials, which might not always result optimal OAR doses. We herein propose a mathematical model to predict the lowest OAR doses among these three positions, providing a quantitative tool for corresponding clinical decision. Methods: Patients were scanned in FB, DIBH, and prone positions under an IRB approved protocol. Tangential beam plans were generated for each position, and OAR doses were calculated.more » The position with least OAR doses is defined as the optimal position. The following features were extracted from each scan to build the model: heart, ipsilateral lung, breast volume, in-field heart, ipsilateral lung volume, distance between heart and target, laterality of heart, and dose to heart and ipsilateral lung. Principal Components Analysis (PCA) was applied to remove the co-linearity of the input data and also to lower the data dimensionality. Feature selection, another method to reduce dimensionality, was applied as a comparison. Support Vector Machine (SVM) was then used for classification. Thirtyseven patient data were acquired; up to now, five patient plans were available. K-fold cross validation was used to validate the accuracy of the classifier model with small training size. Results: The classification results and K-fold cross validation demonstrated the model is capable of predicting the optimal position for patients. The accuracy of K-fold cross validations has reached 80%. Compared to PCA, feature selection allows causal features of dose to be determined. This provides more clinical insights. Conclusion: The proposed classification system appeared to be feasible. We are generating plans for the rest of the 37 patient images, and more statistically significant results are to be presented.« less

  8. MO-G-BRE-09: Validating FMEA Against Incident Learning Data: A Study in Stereotactic Body Radiation Therapy

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Yang, F; Cao, N; Young, L

    2014-06-15

    Purpose: Though FMEA (Failure Mode and Effects Analysis) is becoming more widely adopted for risk assessment in radiation therapy, to our knowledge it has never been validated against actual incident learning data. The objective of this study was to perform an FMEA analysis of an SBRT (Stereotactic Body Radiation Therapy) treatment planning process and validate this against data recorded within an incident learning system. Methods: FMEA on the SBRT treatment planning process was carried out by a multidisciplinary group including radiation oncologists, medical physicists, and dosimetrists. Potential failure modes were identified through a systematic review of the workflow process. Failuremore » modes were rated for severity, occurrence, and detectability on a scale of 1 to 10 and RPN (Risk Priority Number) was computed. Failure modes were then compared with historical reports identified as relevant to SBRT planning within a departmental incident learning system that had been active for two years. Differences were identified. Results: FMEA identified 63 failure modes. RPN values for the top 25% of failure modes ranged from 60 to 336. Analysis of the incident learning database identified 33 reported near-miss events related to SBRT planning. FMEA failed to anticipate 13 of these events, among which 3 were registered with severity ratings of severe or critical in the incident learning system. Combining both methods yielded a total of 76 failure modes, and when scored for RPN the 13 events missed by FMEA ranked within the middle half of all failure modes. Conclusion: FMEA, though valuable, is subject to certain limitations, among them the limited ability to anticipate all potential errors for a given process. This FMEA exercise failed to identify a significant number of possible errors (17%). Integration of FMEA with retrospective incident data may be able to render an improved overview of risks within a process.« less

  9. Validation for the Tropical Rainfall Measuring Mission: Lessons Learned and Future Plans

    NASA Technical Reports Server (NTRS)

    Wolff, David B.; Amitai, E.; Marks, D. A.; Silberstein, D.; Lawrence, R. J.

    2005-01-01

    The Tropical Rainfall Measuring Mission (TRMM) was launched in November 1997 and is a highly regarded and successful mission. A major component of the TRMM program was its Ground Validation (GV) program. Through dedicated research and hard work by many groups, both the GV and satellite-retrieved rain estimates have shown a convergence at key GV sites, lending credibility to the global TRMM estimates. To be sure, there are some regional differences between the various satellite estimates themselves, which still need to be addressed; however, it can be said with some certainty that TRMM has provided a high-quality, long-term climatological data set for researchers that provides errors on the order of 10-20%, rather than pre-TRMM era error estimates on the order of 50-100%. The TRMM GV program's main operational task is to provide rainfall products for four sites: Darwin, Australia (DARW); Houston, Texas (HSTN); Kwajalein, Republic of the Marshall Islands (KWAJ); and, Melbourne, Florida (MELB). A comparison between TRMM Ground Validation (Version 5) and Satellite (Version 6) rain intensity estimates is presented. The gridded satellite product (3668) will be compared to GV Level II rain-intensity and -type maps (2A53 and 2A54, respectively). The 3G68 product represents a 0.5 deg x 0.5 deg data grid providing estimates of rain intensities from the TRMM Precipitation Radar (PR), Microwave Imager (TMI) and Combined (COM) algorithms. The comparisons will be sub-setted according to geographical type (land, coast and ocean). The convergence of the GV and satellite estimates bodes well for expectations for the proposed Global Precipitation Measurement (GPM) program and this study and others are being leveraged towards planning GV goals for GPM. A discussion of lessons learned and future plans for TRMM GV in planning for GPM will also be provided.

  10. Validating FMEA output against incident learning data: A study in stereotactic body radiation therapy.

    PubMed

    Yang, F; Cao, N; Young, L; Howard, J; Logan, W; Arbuckle, T; Sponseller, P; Korssjoen, T; Meyer, J; Ford, E

    2015-06-01

    Though failure mode and effects analysis (FMEA) is becoming more widely adopted for risk assessment in radiation therapy, to our knowledge, its output has never been validated against data on errors that actually occur. The objective of this study was to perform FMEA of a stereotactic body radiation therapy (SBRT) treatment planning process and validate the results against data recorded within an incident learning system. FMEA on the SBRT treatment planning process was carried out by a multidisciplinary group including radiation oncologists, medical physicists, dosimetrists, and IT technologists. Potential failure modes were identified through a systematic review of the process map. Failure modes were rated for severity, occurrence, and detectability on a scale of one to ten and risk priority number (RPN) was computed. Failure modes were then compared with historical reports identified as relevant to SBRT planning within a departmental incident learning system that has been active for two and a half years. Differences between FMEA anticipated failure modes and existing incidents were identified. FMEA identified 63 failure modes. RPN values for the top 25% of failure modes ranged from 60 to 336. Analysis of the incident learning database identified 33 reported near-miss events related to SBRT planning. Combining both methods yielded a total of 76 possible process failures, of which 13 (17%) were missed by FMEA while 43 (57%) identified by FMEA only. When scored for RPN, the 13 events missed by FMEA ranked within the lower half of all failure modes and exhibited significantly lower severity relative to those identified by FMEA (p = 0.02). FMEA, though valuable, is subject to certain limitations. In this study, FMEA failed to identify 17% of actual failure modes, though these were of lower risk. Similarly, an incident learning system alone fails to identify a large number of potentially high-severity process errors. Using FMEA in combination with incident learning may render an improved overview of risks within a process.

  11. Small Business: Action Needed to Determine Whether DOD’s Comprehensive Subcontracting Plan Test Program Should Be Made Permanent

    DTIC Science & Technology

    2015-11-01

    collected. We determined that the methodologies were valid and the data were reliable for our purposes. In addition, we interviewed DOD officials and...of contracts and cost of labor involved in preparing program documentation, to arrive at the estimates for savings. To validate the data used in the...studies to be reasonable, and the data were sufficiently reliable for our purposes. We interviewed officials from DOD and 5 of the 12 Test Program

  12. Release Fixed Heel Point (FHP) Accommodation Model Verification and Validation (V and V) Plan - Rev A

    DTIC Science & Technology

    2017-01-23

    5e. TASK NUMBER N/A 5f. WORK UNIT NUMBER N/A 7. PERFORMING ORGANIZATION NAME(S) AND ADDRESS(ES) AND ADDRESS(ES) RDECOM-TARDEC-ACT Attn...occupant work space, central 90% of the Soldier population, encumbrance, posture and position, verification and validation, computer aided design...factors engineers could benefit by working with vehicle designers to perform virtual assessments in CAD when there is not enough time and/or funding to

  13. Information Resource Management in the DCSPLANS (Deputy Chief of Staff for Plans) Branch of the U.S. Army Military Personnel Center

    DTIC Science & Technology

    1986-11-15

    Richard E. Broome [Broome 1985], Major Robert M. DiBona [ DiBona 1985], Major Robert A. Kirsch II [Kirsch 1985], and Major Alan F. Noel, Jr. [Noel 1985...Major Kirsch expanded this prototype to be compatible with the emerging Federal standards for dictionary systems. Major DiBona analyzed data validation...described in [Noel 1985, Kirsch 1985]. The implementation of edit validation rules in a dictionary environment is covered in [ DiBona 1985] and implementation

  14. CrossTalk: The Journal of Defense Software Engineering. Volume 26, Number 6, November/December 2013

    DTIC Science & Technology

    2013-12-01

    requirements during sprint planning. Automated scanning, which includes automated code-review tools, allows the expert to monitor the system... sprint . This enables the validator to leverage the test results for formal validation and verification, and perform a shortened “hybrid” style of IV&V...per SPRINT (1-4 weeks) 1 week 1 Month Up to four months Ø Deliverable product to user Ø Security posture assessed Ø Accredited to field/operate

  15. Chemical decontamination technical resources at Los Alamos National Laboratory (2008)

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Moore, Murray E

    This document supplies information resources for a person seeking to create planning or pre-planning documents for chemical decontamination operations. A building decontamination plan can be separated into four different sections: Pre-planning, Characterization, Decontamination (Initial response and also complete cleanup), and Clearance. Of the identified Los Alamos resources, they can be matched with these four sections: Pre-planning -- Dave Seidel, EO-EPP, Emergency Planning and Preparedness; David DeCroix and Bruce Letellier, D-3, Computational fluids modeling of structures; Murray E. Moore, RP-2, Aerosol sampling and ventilation engineering. Characterization (this can include development projects) -- Beth Perry, IAT-3, Nuclear Counterterrorism Response (SNIPER database); Fernandomore » Garzon, MPA-11, Sensors and Electrochemical Devices (development); George Havrilla, C-CDE, Chemical Diagnostics and Engineering; Kristen McCabe, B-7, Biosecurity and Public Health. Decontamination -- Adam Stively, EO-ER, Emergency Response; Dina Matz, IHS-IP, Industrial hygiene; Don Hickmott, EES-6, Chemical cleanup. Clearance (validation) -- Larry Ticknor, CCS-6, Statistical Sciences.« less

  16. Moving survivorship care plans forward: focus on care coordination.

    PubMed

    Salz, Talya; Baxi, Shrujal

    2016-07-01

    After completing treatment for cancer, the coordination of oncology and primary care presents a challenge for cancer survivors. Many survivors need continued oncology follow-up, and all survivors require primary care. Coordinating the shared care of a cancer survivor, or facilitating an informed handoff from oncology to primary care, is essential for cancer survivors. Survivorship care plans are personalized documents that summarize cancer treatment and outline a plan of recommended ongoing care, with the goal of facilitating the coordination of post-treatment care. Despite their face validity, five trials have failed to demonstrate the effectiveness of survivorship care plans. We posit that these existing trials have critical shortcomings and do not adequately address whether survivorship care plans improve care coordination. Moving forward, we propose four criteria for future trials of survivorship care plans: focusing on high-needs survivor populations, tailoring the survivorship care plan to the care setting, facilitating implementation of the survivorship care plan in clinical practice, and selecting appropriate trial outcomes to assess care coordination. When trials meet these criteria, we can finally assess whether survivorship care plans help cancer survivors receive optimal oncology and primary care. © 2016 The Authors. Cancer Medicine published by John Wiley & Sons Ltd.

  17. Optimum-AIV: A planning and scheduling system for spacecraft AIV

    NASA Technical Reports Server (NTRS)

    Arentoft, M. M.; Fuchs, Jens J.; Parrod, Y.; Gasquet, Andre; Stader, J.; Stokes, I.; Vadon, H.

    1991-01-01

    A project undertaken for the European Space Agency (ESA) is presented. The project is developing a knowledge based software system for planning and scheduling of activities for spacecraft assembly, integration, and verification (AIV). The system extends into the monitoring of plan execution and the plan repair phase. The objectives are to develop an operational kernel of a planning, scheduling, and plan repair tool, called OPTIMUM-AIV, and to provide facilities which will allow individual projects to customize the kernel to suit its specific needs. The kernel shall consist of a set of software functionalities for assistance in initial specification of the AIV plan, in verification and generation of valid plans and schedules for the AIV activities, and in interactive monitoring and execution problem recovery for the detailed AIV plans. Embedded in OPTIMUM-AIV are external interfaces which allow integration with alternative scheduling systems and project databases. The current status of the OPTIMUM-AIV project, as of Jan. 1991, is that a further analysis of the AIV domain has taken place through interviews with satellite AIV experts, a software requirement document (SRD) for the full operational tool was approved, and an architectural design document (ADD) for the kernel excluding external interfaces is ready for review.

  18. Analytical Plan for Roman Glasses

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Strachan, Denis M.; Buck, Edgar C.; Mueller, Karl T.

    Roman glasses that have been in the sea or underground for about 1800 years can serve as the independent “experiment” that is needed for validation of codes and models that are used in performance assessment. Two sets of Roman-era glasses have been obtained for this purpose. One set comes from the sunken vessel the Iulia Felix; the second from recently excavated glasses from a Roman villa in Aquileia, Italy. The specimens contain glass artifacts and attached sediment or soil. In the case of the Iulia Felix glasses quite a lot of analytical work has been completed at the University ofmore » Padova, but from an archaeological perspective. The glasses from Aquileia have not been so carefully analyzed, but they are similar to other Roman glasses. Both glass and sediment or soil need to be analyzed and are the subject of this analytical plan. The glasses need to be analyzed with the goal of validating the model used to describe glass dissolution. The sediment and soil need to be analyzed to determine the profile of elements released from the glass. This latter need represents a significant analytical challenge because of the trace quantities that need to be analyzed. Both pieces of information will yield important information useful in the validation of the glass dissolution model and the chemical transport code(s) used to determine the migration of elements once released from the glass. In this plan, we outline the analytical techniques that should be useful in obtaining the needed information and suggest a useful starting point for this analytical effort.« less

  19. Reach and Validity of an Objective Medication Adherence Measure Among Safety Net Health Plan Members with Diabetes: A Cross-Sectional Study.

    PubMed

    Ratanawongsa, Neda; Karter, Andrew J; Quan, Judy; Parker, Melissa M; Handley, Margaret; Sarkar, Urmimala; Schmittdiel, Julie A; Schillinger, Dean

    2015-08-01

    With the expansion of Medicaid and low-cost health insurance plans among diverse patient populations, objective measures of medication adherence using pharmacy claims could advance clinical care and translational research for safety net care. However, safety net patients may experience fluctuating prescription drug coverage, affecting the performance of adherence measures. To evaluate the performance of continuous medication gap (CMG) for diverse, low-income managed care members with diabetes. We conducted this cross-sectional analysis using administrative and clinical data for 680 members eligible for a self-management support trial at a nonprofit, government-sponsored managed care plan. We applied CMG methodology to cardiometabolic medication claims for English- , Cantonese- , or Spanish-speaking members with diabetes. We examined inclusiveness (the proportion with calculable CMG) and selectivity (sociodemographic and medical differences from members without CMG). For validity, we examined unadjusted associations of suboptimal adherence (CMG >  20%) with suboptimal cardiometabolic control. 429 members (63%) had calculable CMG. Compared with members without CMG, members with CMG were younger, more likely employed, and had poorer glycemic control but had better blood pressure and lipid control. Suboptimal adherence occurred more frequently among members with poor cardiometabolic control than among members with optimal control (28% vs. 12%, P = 0.02). CMG demonstrated acceptable inclusiveness and validity in a diverse, low-income safety net population, comparable with its performance in studies among other insured populations. CMG may provide a useful tool to measure adherence among increasingly diverse Medicaid populations, complemented by other strategies to reach those not captured by CMG.

  20. Tactical Combat Forces of the United States Air Force: Issues and Alternatives

    DTIC Science & Technology

    1985-04-01

    information if it does not display a currently valid OMB control number. 1. REPORT DATE APR 1985 2. REPORT TYPE 3. DATES COVERED 00-00-1985 to 00-00-1985...because of rounding. All costs are expressed in current dollars of budget authority, using the Administration’s February 1985 economic assumptions...plans and discusses the effects of current plans for fighter development on future forces. The study was re~ quested by the Defense Subcommittee of

  1. [MODIS Investigation

    NASA Technical Reports Server (NTRS)

    Abbott, Mark R.

    1996-01-01

    The objectives of the last six months were: (1) Complete sensitivity analysis of fluorescence; line height algorithms (2) Deliver fluorescence algorithm code and test data to the University of Miami for integration; (3) Complete analysis of bio-optical data from Southern Ocean cruise; (4) Conduct laboratory experiments based on analyses of field data; (5) Analyze data from bio-optical mooring off Hawaii; (6) Develop calibration/validation plan for MODIS fluorescence data; (7) Respond to the Japanese Research Announcement for GLI; and (8) Continue to review plans for EOSDIS and assist ECS contractor.

  2. Analytical and Experimental Study to Improve Computer Models for Mixing and Dilution of Soluble Hazardous Chemicals.

    DTIC Science & Technology

    1982-08-01

    Trajectory and Concentration of Various Plumes 59 IV.2 Tank and Cargo Geometry Assumed for Discharge Rate Calculation Using HACS Venting Rate Model 61...Discharge Rate Calculation Using HACS Venting Rate Model 62 IV.4 Original Test Plan for Validation of the Continuous Spill Model 66 IV.5 Final Test Plan...at t= 0. exEyEz = turbulent diffusivities. p = water density. Pc = chemical density. Symbols Used Only in Continuous-Spill Models for a Steady River b

  3. Plan for the Assessment and Evaluation of Individual and Team Proficiencies Developed by the DARWARS Environments

    DTIC Science & Technology

    2004-12-31

    Research, 58( 1 ), 47-77. Herl, H. E., O’Neil, H. F ., Jr., Chung, G., & Schacter, J. (1999) Reliability and validity of a computer-based knowledge mapping...simulation: A meta analysis. International Journal of Instructional Media, 26( 1 ), 71-85. Leemkuil, H., de Jong, T., de Hoog , R., & Christoph, N. (2003...FINAL REPORT ON PLAN FOR THE ASSESSMENT AND EVALUATION OF INDIVIDUAL AND TEAM PROFICIENCIES DEVELOPED BY THE DARWARS ENVIRONMENTS Harold F . O’Neil

  4. GlobPermafrost- How Space-BasedEarth Observation Supports Understanding of Permafrost

    NASA Astrophysics Data System (ADS)

    Bartsch, Annett; Grosse, Guido; Kaab, Andreas; Westermann, Sebastian; Strozzi, Tazio; Wiesmann, Andreas; Duguay, Claude; Seifert, Frank Martin; Obu, Jaroslav; Goler, Robert

    2016-08-01

    The GlobPermafrost project develops, validates and implements Earth Observation (EO) products to support research communities and international organisations in their work on better understanding permafrost characteristics and dynamics. To facilitate usability of these products by the target audience, user requirements with respect to the planned products have been requested and collected through an online community survey as well as by interview. This paper provides an overview on the planned thematic EO products as well as results of the user requirement survey.

  5. Implementation of National Space Policy on US Air Force End of Life Operations and Orbital Debris Mitigation

    DTIC Science & Technology

    2012-06-01

    procedures have been driven by the rising significance of the orbital debris problem in Low Earth Orbit (LEO). Therefore current EOL plans are...does not display a currently valid OMB control number. 1. REPORT DATE JUN 2012 2. REPORT TYPE 3. DATES COVERED 00-00-2012 to 00-00-2012 4...by the rising significance of the orbital debris problem in Low Earth Orbit (LEO). Therefore current EOL plans are written largely with the aim of

  6. An Analysis of the Navy’s Fiscal Year 2014 Shipbuilding Plan

    DTIC Science & Technology

    2013-10-23

    fuel and a few other supplies to ships at sea) at a rate of 1 per year through the 2020s; that program would conclude in 2033. The plan also...reporting burden for the collection of information is estimated to average 1 hour per response, including the time for reviewing instructions, searching...information if it does not display a currently valid OMB control number. 1 . REPORT DATE 23 OCT 2013 2. REPORT TYPE 3. DATES COVERED 00-00-2013 to 00-00

  7. An Analysis of the Navy’s Fiscal Year 2013 Shipbuilding Plan

    DTIC Science & Technology

    2012-07-01

    Documentation Page Form ApprovedOMB No. 0704-0188 Public reporting burden for the collection of information is estimated to average 1 hour per response...penalty for failing to comply with a collection of information if it does not display a currently valid OMB control number. 1 . REPORT DATE JUL 2012 2...4456 ContentsSummary iii Changes in Inventory Goals Under the 2013 Plan 1 Box 1 . The Roles of Major Types of Ships in the Navy’s Battle Force Fleet 2

  8. CMC Research at NASA Glenn in 2016: Recent Progress and Plans

    NASA Technical Reports Server (NTRS)

    Grady, Joseph E.

    2016-01-01

    As part of NASA's Aeronautical Sciences project, Glenn Research Center has developed advanced fiber and matrix constituents for a 2700 degrees Fahrenheit CMC (Ceramic Matrix Composite) for turbine engine applications. Fiber and matrix development and characterization will be reviewed. Resulting improvements in CMC mechanical properties and durability will be summarized. Plans for 2015 will be described, including development and validation of models predicting effects of the engine environment on durability of SiCSiC composites with Environmental Barrier Coatings (EBCs).

  9. Content Analysis for Proactive Protective Intelligence

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Sanfilippo, Antonio P.

    The aim of this paper is to outline a plan for developing and validating a Proactive Protective Intelligence approach that prevents targeted violence through the analysis and assessment of threats overtly or covertly expressed in abnormal communications to USSS protectees.

  10. Milestones Since Last Workshop [Global Positioning System Adjacent Band Compatibility Assessment Workshop V, 10/14/2016

    DOT National Transportation Integrated Search

    2016-10-14

    Milestones Since Last Workshop - Finalized GPS/GNSS receiver test plan and test procedures - Coordinated government and manufacturer participation and executed Non-Disclosure Agreements (NDAs) - Developed/validated radiated RF test environment - Carr...

  11. Development and Calibration of Highway Safety Manual Equations for Florida Conditions

    DOT National Transportation Integrated Search

    2011-08-31

    The Highway Safety Manual (HSM) provides statistically-valid analytical tools and techniques for quantifying the potential effects on crashes as a result of decisions made in planning, design, operations, and maintenance. Implementation of the new te...

  12. Development and calibration of highway safety manual equations for Florida conditions.

    DOT National Transportation Integrated Search

    2011-08-31

    The Highway Safety Manual (HSM) provides statistically-valid analytical tools and techniques for : quantifying the potential effects on crashes as a result of decisions made in planning, design, : operations, and maintenance. Implementation of the ne...

  13. Supporting statement for community study of human response to aircraft noise

    NASA Technical Reports Server (NTRS)

    Dempsey, T. K.; Deloach, R.; Stephens, D. G.

    1980-01-01

    A study plan for quantifying the relationship between human annoyance and the noise level of individual aircraft events is studied. The validity of various noise descriptors or noise metrics for quantifying aircraft noise levels are assessed.

  14. ASK ME--A Merit Promotion System

    ERIC Educational Resources Information Center

    Johnson, Michael L.; McCloskey, Kenneth R.

    1978-01-01

    Describes a procedure developed at the Red River Army Depot, Texarkana, Texas, for selecting and evaluating personnel called AKS ME (Ability, Skill and Knowledge Merit Evaluation), consisting of four basic steps: job analysis, examination plan, candidate evaluation, and validation. (MF)

  15. 78 FR 45598 - Industry Forums on the Next ITS Strategic Plan; Notice of Public Meeting

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-07-29

    ... of critical thinking tools designed to draw out information to identify and validate focus areas for... inputs through an online tool, IdeaScale at http://itsstrategicplan.ideascale.com . The first facilitated...

  16. Integrated Land - Use , Transportation and Environmental Modeling : Validation Case Studies

    DOT National Transportation Integrated Search

    2010-08-01

    For decades the transportation-planning research community has acknowledged the interactions between the evolution of our transportation systems and our land-use, and the need to unify the practices of land-use forecasting and travel-demand modeling ...

  17. SU-E-T-516: Dosimetric Validation of AcurosXB Algorithm in Comparison with AAA & CCC Algorithms for VMAT Technique.

    PubMed

    Kathirvel, M; Subramanian, V Sai; Arun, G; Thirumalaiswamy, S; Ramalingam, K; Kumar, S Ashok; Jagadeesh, K

    2012-06-01

    To dosimetrically validate AcurosXB algorithm for Volumetric Modulated Arc Therapy (VMAT) in comparison with standard clinical Anisotropic Analytic Algorithm(AAA) and Collapsed Cone Convolution(CCC) dose calculation algorithms. AcurosXB dose calculation algorithm is available with Varian Eclipse treatment planning system (V10). It uses grid-based Boltzmann equation solver to predict dose precisely in lesser time. This study was made to realize algorithms ability to predict dose accurately as its delivery for which five clinical cases each of Brain, Head&Neck, Thoracic, Pelvic and SBRT were taken. Verification plans were created on multicube phantom with iMatrixx-2D detector array and then dose prediction was done with AcurosXB, AAA & CCC (COMPASS System) algorithm and the same were delivered onto CLINAC-iX treatment machine. Delivered dose was captured in iMatrixx plane for all 25 plans. Measured dose was taken as reference to quantify the agreement between AcurosXB calculation algorithm against previously validated AAA and CCC algorithm. Gamma evaluation was performed with clinical criteria distance-to-agreement 3&2mm and dose difference 3&2% in omnipro-I'MRT software. Plans were evaluated in terms of correlation coefficient, quantitative area gamma and average gamma. Study shows good agreement between mean correlation 0.9979±0.0012, 0.9984±0.0009 & 0.9979±0.0011 for AAA, CCC & Acuros respectively. Mean area gamma for criteria 3mm/3% was found to be 98.80±1.04, 98.14±2.31, 98.08±2.01 and 2mm/2% was found to be 93.94±3.83, 87.17±10.54 & 92.36±5.46 for AAA, CCC & Acuros respectively. Mean average gamma for 3mm/3% was 0.26±0.07, 0.42±0.08, 0.28±0.09 and 2mm/2% was found to be 0.39±0.10, 0.64±0.11, 0.42±0.13 for AAA, CCC & Acuros respectively. This study demonstrated that the AcurosXB algorithm had a good agreement with the AAA & CCC in terms of dose prediction. In conclusion AcurosXB algorithm provides a valid, accurate and speedy alternative to AAA and CCC algorithms in a busy clinical environment. © 2012 American Association of Physicists in Medicine.

  18. SU-F-BRF-10: Deformable MRI to CT Validation Employing Same Day Planning MRI for Surrogate Analysis

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Padgett, K; Stoyanova, R; Johnson, P

    Purpose: To compare rigid and deformable registrations of the prostate in the multi-modality setting (diagnostic-MRI to planning-CT) by utilizing a planning-MRI as a surrogate. The surrogate allows for the direct quantitative analysis which can be difficult in the multi-modality domain where intensity mapping differs. Methods: For ten subjects, T2 fast-spin-echo images were acquired at two different time points, the first several weeks prior to planning (diagnostic-MRI) and the second on the same day in which the planning CT was collected (planning-MRI). Significant effort in patient positioning and bowel/bladder preparation was undertaken to minimize distortion of the prostate in all datasets.more » The diagnostic-MRI was deformed to the planning-CT utilizing a commercially available deformable registration algorithm synthesized from local registrations. The deformed MRI was then rigidly aligned to the planning MRI which was used as the surrogate for the planning-CT. Agreement between the two MRI datasets was scored using intensity based metrics including Pearson correlation and normalized mutual information, NMI. A local analysis was performed by looking only within the prostate, proximal seminal vesicles, penile bulb and combined areas. A similar method was used to assess a rigid registration between the diagnostic-MRI and planning-CT. Results: Utilizing the NMI, the deformable registrations were superior to the rigid registrations in 9 of 10 cases demonstrating a 15.94% improvement (p-value < 0.001) within the combined area. The Pearson correlation showed similar results with the deformable registration superior in the same number of cases and demonstrating a 6.97% improvement (p-value <0.011). Conclusion: Validating deformable multi-modality registrations using spatial intensity based metrics is difficult due to the inherent differences in intensity mapping. This population provides an ideal testing ground for MRI to CT deformable registrations by obviating the need for multi-modality comparisons which are inherently more challenging. Deformable registrations generated in this work significantly outperformed rigid alignments. Research reported in this abstract was supported by the NIH National Cancer Institute R21CA153826 “MRI-Guided Radiotherapy and Biomarkers for Prostate Cancer” and Bankhead-Coley Cancer Research Program 10BT-03 “MRI-Guided Radiotherapy and Biomarkers for Prostate Cancer”.« less

  19. Systematic synthesis of barriers and facilitators to service user-led care planning.

    PubMed

    Bee, Penny; Price, Owen; Baker, John; Lovell, Karina

    2015-08-01

    Service user (patient) involvement in care planning is a principle enshrined by mental health policy yet often attracts criticism from patients and carers in practice. To examine how user-involved care planning is operationalised within mental health services and to establish where, how and why challenges to service user involvement occur. Systematic evidence synthesis. Synthesis of data from 117 studies suggests that service user involvement fails because the patients' frame of reference diverges from that of providers. Service users and carers attributed highest value to the relational aspects of care planning. Health professionals inconsistently acknowledged the quality of the care planning process, tending instead to define service user involvement in terms of quantifiable service-led outcomes. Service user-involved care planning is typically operationalised as a series of practice-based activities compliant with auditor standards. Meaningful involvement demands new patient-centred definitions of care planning quality. New organisational initiatives should validate time spent with service users and display more tangible and flexible commitments to meeting their needs. © The Royal College of Psychiatrists 2015.

  20. Systematic synthesis of barriers and facilitators to service user-led care planning

    PubMed Central

    Bee, Penny; Price, Owen; Baker, John; Lovell, Karina

    2015-01-01

    Background Service user (patient) involvement in care planning is a principle enshrined by mental health policy yet often attracts criticism from patients and carers in practice. Aims To examine how user-involved care planning is operationalised within mental health services and to establish where, how and why challenges to service user involvement occur. Method Systematic evidence synthesis. Results Synthesis of data from 117 studies suggests that service user involvement fails because the patients' frame of reference diverges from that of providers. Service users and carers attributed highest value to the relational aspects of care planning. Health professionals inconsistently acknowledged the quality of the care planning process, tending instead to define service user involvement in terms of quantifiable service-led outcomes. Conclusions Service user-involved care planning is typically operationalised as a series of practice-based activities compliant with auditor standards. Meaningful involvement demands new patient-centred definitions of care planning quality. New organisational initiatives should validate time spent with service users and display more tangible and flexible commitments to meeting their needs. PMID:26243762

Top