Sample records for validation results demonstrate

  1. High dynamic GPS receiver validation demonstration

    NASA Technical Reports Server (NTRS)

    Hurd, W. J.; Statman, J. I.; Vilnrotter, V. A.

    1985-01-01

    The Validation Demonstration establishes that the high dynamic Global Positioning System (GPS) receiver concept developed at JPL meets the dynamic tracking requirements for range instrumentation of missiles and drones. It was demonstrated that the receiver can track the pseudorange and pseudorange rate of vehicles with acceleration in excess of 100 g and jerk in excess of 100 g/s, dynamics ten times more severe than specified for conventional High Dynamic GPS receivers. These results and analytic extensions to a complete system configuration establish that all range instrumentation requirements can be met. The receiver can be implemented in the 100 cu in volume required by all missiles and drones, and is ideally suited for transdigitizer or translator applications.

  2. Marketing Plan for Demonstration and Validation Assets

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    None, None

    The National Security Preparedness Project (NSPP), is to be sustained by various programs, including technology demonstration and evaluation (DEMVAL). This project assists companies in developing technologies under the National Security Technology Incubator program (NSTI) through demonstration and validation of technologies applicable to national security created by incubators and other sources. The NSPP also will support the creation of an integrated demonstration and validation environment. This report documents the DEMVAL marketing and visibility plan, which will focus on collecting information about, and expanding the visibility of, DEMVAL assets serving businesses with national security technology applications in southern New Mexico.

  3. A Design to Improve Internal Validity of Assessments of Teaching Demonstrations

    ERIC Educational Resources Information Center

    Bartsch, Robert A.; Engelhardt Bittner, Wendy M.; Moreno, Jesse E., Jr.

    2008-01-01

    Internal validity is important in assessing teaching demonstrations both for one's knowledge and for quality assessment demanded by outside sources. We describe a method to improve the internal validity of assessments of teaching demonstrations: a 1-group pretest-posttest design with alternative forms. This design is often more practical and…

  4. Validation of Solar Sail Simulations for the NASA Solar Sail Demonstration Project

    NASA Technical Reports Server (NTRS)

    Braafladt, Alexander C.; Artusio-Glimpse, Alexandra B.; Heaton, Andrew F.

    2014-01-01

    NASA's Solar Sail Demonstration project partner L'Garde is currently assembling a flight-like sail assembly for a series of ground demonstration tests beginning in 2015. For future missions of this sail that might validate solar sail technology, it is necessary to have an accurate sail thrust model. One of the primary requirements of a proposed potential technology validation mission will be to demonstrate solar sail thrust over a set time period, which for this project is nominally 30 days. This requirement would be met by comparing a L'Garde-developed trajectory simulation to the as-flown trajectory. The current sail simulation baseline for L'Garde is a Systems Tool Kit (STK) plug-in that includes a custom-designed model of the L'Garde sail. The STK simulation has been verified for a flat plate model by comparing it to the NASA-developed Solar Sail Spaceflight Simulation Software (S5). S5 matched STK with a high degree of accuracy and the results of the validation indicate that the L'Garde STK model is accurate enough to meet the potential future mission requirements. Additionally, since the L'Garde sail deviates considerably from a flat plate, a force model for a non-flat sail provided by L'Garde sail was also tested and compared to a flat plate model in S5. This result will be used in the future as a basis of comparison to the non-flat sail model being developed for STK.

  5. A Valid Demonstration of the Missing Fundamental Illusion.

    ERIC Educational Resources Information Center

    Larsen, Janet D.; Fritsch, Klaus

    1998-01-01

    Identifies the "missing fundamental illusion" as that which occurs when two tones are heard together and the listener hears a third tone with a pitch corresponding to the difference in their frequencies. Describes an inexpensive and valid demonstration of the missing fundamental using a British police whistle. (MJP)

  6. NDARC - NASA Design and Analysis of Rotorcraft Validation and Demonstration

    NASA Technical Reports Server (NTRS)

    Johnson, Wayne

    2010-01-01

    Validation and demonstration results from the development of the conceptual design tool NDARC (NASA Design and Analysis of Rotorcraft) are presented. The principal tasks of NDARC are to design a rotorcraft to satisfy specified design conditions and missions, and then analyze the performance of the aircraft for a set of off-design missions and point operating conditions. The aircraft chosen as NDARC development test cases are the UH-60A single main-rotor and tail-rotor helicopter, the CH-47D tandem helicopter, the XH-59A coaxial lift-offset helicopter, and the XV-15 tiltrotor. These aircraft were selected because flight performance data, a weight statement, detailed geometry information, and a correlated comprehensive analysis model are available for each. Validation consists of developing the NDARC models for these aircraft by using geometry and weight information, airframe wind tunnel test data, engine decks, rotor performance tests, and comprehensive analysis results; and then comparing the NDARC results for aircraft and component performance with flight test data. Based on the calibrated models, the capability of the code to size rotorcraft is explored.

  7. Demonstrating Experimenter "Ineptitude" as a Means of Teaching Internal and External Validity

    ERIC Educational Resources Information Center

    Treadwell, Kimberli R.H.

    2008-01-01

    Internal and external validity are key concepts in understanding the scientific method and fostering critical thinking. This article describes a class demonstration of a "botched" experiment to teach validity to undergraduates. Psychology students (N = 75) completed assessments at the beginning of the semester, prior to and immediately following…

  8. Definition and Demonstration of a Methodology for Validating Aircraft Trajectory Predictors

    NASA Technical Reports Server (NTRS)

    Vivona, Robert A.; Paglione, Mike M.; Cate, Karen T.; Enea, Gabriele

    2010-01-01

    This paper presents a new methodology for validating an aircraft trajectory predictor, inspired by the lessons learned from a number of field trials, flight tests and simulation experiments for the development of trajectory-predictor-based automation. The methodology introduces new techniques and a new multi-staged approach to reduce the effort in identifying and resolving validation failures, avoiding the potentially large costs associated with failures during a single-stage, pass/fail approach. As a case study, the validation effort performed by the Federal Aviation Administration for its En Route Automation Modernization (ERAM) system is analyzed to illustrate the real-world applicability of this methodology. During this validation effort, ERAM initially failed to achieve six of its eight requirements associated with trajectory prediction and conflict probe. The ERAM validation issues have since been addressed, but to illustrate how the methodology could have benefited the FAA effort, additional techniques are presented that could have been used to resolve some of these issues. Using data from the ERAM validation effort, it is demonstrated that these new techniques could have identified trajectory prediction error sources that contributed to several of the unmet ERAM requirements.

  9. Demonstrating the validity of three general scores of PET in predicting higher education achievement in Israel.

    PubMed

    Oren, Carmel; Kennet-Cohen, Tamar; Turvall, Elliot; Allalouf, Avi

    2014-01-01

    The Psychometric Entrance Test (PET), used for admission to higher education in Israel together with the Matriculation (Bagrut), had in the past one general (total) score in which the weights for its domains: Verbal, Quantitative and English, were 2:2:1, respectively. In 2011, two additional total scores were introduced, with different weights for the Verbal and the Quantitative domains. This study compares the predictive validity of the three general scores of PET, and demonstrates validity in terms of utility. 100,863 freshmen students of all Israeli universities over the classes of 2005-2009. Regression weights and correlations of the predictors with FYGPA were computed. Simulations based on these results supplied the utility estimates. On average, PET is slightly more predictive than the Bagrut; using them both yields a better tool than either of them alone. Assigning differential weights to the components in the respective schools further improves the validity. The introduction of the new general scores of PET is validated by gathering and analyzing evidence based on relations of test scores to other variables. The utility of using the test can be demonstrated in ways different from correlations.

  10. Controlled Hydrogen Fleet and Infrastructure Demonstration and Validation Project

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Stottler, Gary

    General Motors, LLC and energy partner Shell Hydrogen, LLC, deployed a system of hydrogen fuel cell electric vehicles integrated with a hydrogen fueling station infrastructure to operate under real world conditions as part of the U.S. Department of Energy's Controlled Hydrogen Fleet and Infrastructure Validation and Demonstration Project. This technical report documents the performance and describes the learnings from progressive generations of vehicle fuel cell system technology and multiple approaches to hydrogen generation and delivery for vehicle fueling.

  11. Laboratory Validation and Demonstrations of Non-Hexavalent Chromium Conversion Coatings for Steel Substrates (Briefing Charts)

    DTIC Science & Technology

    2011-02-01

    UNCLASSIFIED: Approved for public release; distribution unlimited. Laboratory Validation and Demonstrations of Non-Hexavalent Chromium Conversion...00-00-2011 4. TITLE AND SUBTITLE Laboratory Validation and Demonstrations of Non-Hexavalent Chromium Conversion Coatings for Steel Substrates 5a...Coatings for HHA • SurTec 650 - ChromitAL TCP - Trivalent Chrome Pretreatment Developed by NAVAIR for Aluminum. • Chemetall Oxsilan 9810/2 - Non-chrome

  12. Developing a Validity Argument through Abductive Reasoning with an Empirical Demonstration of the Latent Class Analysis

    ERIC Educational Resources Information Center

    Wu, Amery D.; Stone, Jake E.; Liu, Yan

    2016-01-01

    This article proposes and demonstrates a methodology for test score validation through abductive reasoning. It describes how abductive reasoning can be utilized in support of the claims made about test score validity. This methodology is demonstrated with a real data example of the Canadian English Language Proficiency Index Program…

  13. Job Embeddedness Demonstrates Incremental Validity When Predicting Turnover Intentions for Australian University Employees

    PubMed Central

    Heritage, Brody; Gilbert, Jessica M.; Roberts, Lynne D.

    2016-01-01

    Job embeddedness is a construct that describes the manner in which employees can be enmeshed in their jobs, reducing their turnover intentions. Recent questions regarding the properties of quantitative job embeddedness measures, and their predictive utility, have been raised. Our study compared two competing reflective measures of job embeddedness, examining their convergent, criterion, and incremental validity, as a means of addressing these questions. Cross-sectional quantitative data from 246 Australian university employees (146 academic; 100 professional) was gathered. Our findings indicated that the two compared measures of job embeddedness were convergent when total scale scores were examined. Additionally, job embeddedness was capable of demonstrating criterion and incremental validity, predicting unique variance in turnover intention. However, this finding was not readily apparent with one of the compared job embeddedness measures, which demonstrated comparatively weaker evidence of validity. We discuss the theoretical and applied implications of these findings, noting that job embeddedness has a complementary place among established determinants of turnover intention. PMID:27199817

  14. Newberry Volcano EGS Demonstration - Phase I Results

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Osborn, William L.; Petty, Susan; Cladouhos, Trenton T.

    Phase I of the Newberry Volcano Enhanced Geothermal System (EGS) Demonstration included permitting, community outreach, seismic hazards analysis, initial microseismic array deployment and calibration, final MSA design, site characterization, and stimulation planning. The multi-disciplinary Phase I site characterization supports stimulation planning and regulatory permitting, as well as addressing public concerns including water usage and induced seismicity. A review of the project's water usage plan by an independent hydrology consultant found no expected impacts to local stakeholders, and recommended additional monitoring procedures. The IEA Protocol for Induced Seismicity Associated with Enhanced Geothermal Systems was applied to assess site conditions, properly informmore » stakeholders, and develop a comprehensive mitigation plan. Analysis of precision LiDAR elevation maps has concluded that there is no evidence of recent faulting near the target well. A borehole televiewer image log of the well bore revealed over three hundred fractures and predicted stress orientations. No natural, background seismicity has been identified in a review of historic data, or in more than seven months of seismic data recorded on an array of seven seismometers operating around the target well. A seismic hazards and induced seismicity risk assessment by an independent consultant concluded that the Demonstration would contribute no additional risk to residents of the nearest town of La Pine, Oregon. In Phase II of the demonstration, an existing deep hot well, NWG 55-29, will be stimulated using hydroshearing techniques to create an EGS reservoir. The Newberry Volcano EGS Demonstration is allowing geothermal industry and academic experts to develop, validate and enhance geoscience and engineering techniques, and other procedures essential to the expansion of EGS throughout the country. Successful development will demonstrate to the American public that EGS can play a significant

  15. Demonstration and Validation of Stainless Steel Materials for Critical Above Grade Piping in Highly Corrosive Locations

    DTIC Science & Technology

    2017-05-01

    Protecting And Bonding Reinforcing Steel In Cement -Based Composites, Corrosion 2009, Atlanta, GA, 22-26 March 2009. 7. Hock, V., O. Marshall, S...ER D C/ CE RL T R- 17 -1 3 DoD Corrosion Prevention and Control Program Demonstration and Validation of Stainless Steel Materials for...ERDC/CERL TR-17-13 May 2017 Demonstration and Validation of Stainless Steel Materials for Critical Above-Grade Piping in Highly Corrosive

  16. Demonstration/Validation of Low Volatile Organic Compound (VOC) Chemical Agent Resistant Coating (CARC)

    DTIC Science & Technology

    2003-11-25

    alkyd resin enamel was 14 Figure 1 -- Test Panels Before Application of WD CARC at MCB Figure 2 -- Test Panels with WD CARC Applied at MCB...WD) Chemical Agent Resistant Coating (CARC) patented (#5,691,410) by the Army Research Laboratory (ARL) has undergone technology Demonstration...Resistant Coating (CARC) patented (#5,691,410) by the Army Research Laboratory (ARL) has undergone technology Demonstration/Validation (Dem/Val) testing

  17. Validating Innovative Renewable Energy Technologies: ESTCP Demonstrations at Two DoD Facilities

    DTIC Science & Technology

    2012-05-01

    AND SUBTITLE Validating Innovative Renewable Energy Technologies: ESTCP Demonstrations at Two DoD Facilities 5a. CONTRACT NUMBER 5b. GRANT NUMBER...Southern Research Institute,Advanced Energy Department,2000 Ninth Avenue South,Birmingham,AL,35205-5305 8. PERFORMING ORGANIZATION REPORT NUMBER...AVAILABILITY STATEMENT Approved for public release; distribution unlimited 13. SUPPLEMENTARY NOTES Presented at the NDIA Environment, Energy Security

  18. Validating Innovative Renewable Energy Technologies: ESTCP Demonstrations at Two DoD Facilities

    DTIC Science & Technology

    2011-11-01

    4. TITLE AND SUBTITLE Validating Innovative Renewable Energy Technologies: ESTCP Demonstrations at Two DoD Facilities 5a. CONTRACT NUMBER 5b...goals of 25% of energy consumed required to be from renewable energy by 2025, the DoD has set aggressive, yet achievable targets. With its array of land...holdings facilities, and environments, the potential for renewable energy generation on DoD lands is great. Reaching these goals will require

  19. Simulated Driving Assessment (SDA) for Teen Drivers: Results from a Validation Study

    PubMed Central

    McDonald, Catherine C.; Kandadai, Venk; Loeb, Helen; Seacrist, Thomas S.; Lee, Yi-Ching; Winston, Zachary; Winston, Flaura K.

    2015-01-01

    Background Driver error and inadequate skill are common critical reasons for novice teen driver crashes, yet few validated, standardized assessments of teen driving skills exist. The purpose of this study was to evaluate the construct and criterion validity of a newly developed Simulated Driving Assessment (SDA) for novice teen drivers. Methods The SDA's 35-minute simulated drive incorporates 22 variations of the most common teen driver crash configurations. Driving performance was compared for 21 inexperienced teens (age 16–17 years, provisional license ≤90 days) and 17 experienced adults (age 25–50 years, license ≥5 years, drove ≥100 miles per week, no collisions or moving violations ≤3 years). SDA driving performance (Error Score) was based on driving safety measures derived from simulator and eye-tracking data. Negative driving outcomes included simulated collisions or run-off-the-road incidents. A professional driving evaluator/instructor reviewed videos of SDA performance (DEI Score). Results The SDA demonstrated construct validity: 1.) Teens had a higher Error Score than adults (30 vs. 13, p=0.02); 2.) For each additional error committed, the relative risk of a participant's propensity for a simulated negative driving outcome increased by 8% (95% CI: 1.05–1.10, p<0.01). The SDA demonstrated criterion validity: Error Score was correlated with DEI Score (r=−0.66, p<0.001). Conclusions This study supports the concept of validated simulated driving tests like the SDA to assess novice driver skill in complex and hazardous driving scenarios. The SDA, as a standard protocol to evaluate teen driver performance, has the potential to facilitate screening and assessment of teen driving readiness and could be used to guide targeted skill training. PMID:25740939

  20. Validation of a highly integrated SiPM readout system with a TOF-PET demonstrator

    NASA Astrophysics Data System (ADS)

    Niknejad, T.; Setayeshi, S.; Tavernier, S.; Bugalho, R.; Ferramacho, L.; Di Francesco, A.; Leong, C.; Rolo, M. D.; Shamshirsaz, M.; Silva, J. C.; Silva, R.; Silveira, M.; Zorraquino, C.; Varela, J.

    2016-12-01

    We have developed a highly integrated, fast and compact readout electronics for Silicon Photomultiplier (SiPM) based Time of Flight Positron Emission Tomography (TOF-PET) scanners. The readout is based on the use of TOP-PET Application Specific Integrated Circuit (PETsys TOFPET1 ASIC) with 64 channels, each with its amplifier, discriminator, Time to Digital Converter (TDC) and amplitude determination using Time Over Threshold (TOT). The ASIC has 25 ps r.m.s. intrinsic time resolution and fully digital output. The system is optimised for high rates, good timing, low power consumption and low cost. For validating the readout electronics, we have built a technical PET scanner, hereafter called ``demonstrator'', with 2'048 SiPM channels. The PET demonstrator has 16 compact Detector Modules (DM). Each DM has two ASICs reading 128 SiPM pixels in one-to-one coupling to 128 Lutetium Yttrium Orthosilicate (LYSO) crystals measuring 3.1 × 3.1 × 15 mm3 each. The data acquisition system for the demonstrator has two Front End Boards type D (FEB/D), each collecting the data of 1'024 channels (8 DMs), and transmitting assembled data frames through a serial link (4.8 Gbps), to a single Data Acquisition (DAQ) board plugged into the Peripheral Component Interconnect Express (PCIe) bus of the data acquisition PC. Results obtained with this PET demonstrator are presented.

  1. SPD Hockley County: Results of 1971 Agricultural Demonstrations.

    ERIC Educational Resources Information Center

    Taylor, Bill; Nugent, Gene

    This report presents the statistical results of agricultural demonstrations for two crops--cotton and sorghum--in Hockley County, Texas. Demonstration results are geared to increase the knowledge and understanding of possible solutions to the many problems that are impediments in reaching long-range goals established by the County's Program…

  2. Initial Results from the Majorana Demonstrator

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Elliott, S. R.; Abgrall, N.; Arnquist, I. J.

    The Majorana Collaboration has assembled an array of high purity Ge detectors to search for neutrinoless double-beta decay in 76Ge with the goal of establishing the required background and scalability of a Ge-based next-generation tonne-scale experiment. The Majorana Demonstrator consists of 44 kg of high-purity Ge (HPGe) detectors (30 kg enriched in 76Ge) with a low-noise p-type point contact (PPC) geometry. The detectors are split between two modules which are contained in a single lead and high-purity copper shield at the Sanford Underground Research Facility in Lead, South Dakota. Following a commissioning run that started in June 2015, the fullmore » detector array has been acquiring data since August 2016. We will discuss the status of the Majorana Demonstrator and initial results from the first physics run; including current background estimates, exotic low-energy physics searches, projections on the physics reach of the Demonstrator, and implications for a tonne-scale Ge based Neutrinoless double-beta decay search.« less

  3. Initial Results from the Majorana Demonstrator

    NASA Astrophysics Data System (ADS)

    Elliott, S. R.; Abgrall, N.; Arnquist, I. J.; Avignone, F. T., III.; Barabash, A. S.; Bertrand, F. E.; Bradley, A. W.; Brudanin, V.; Busch, M.; Buuck, M.; Caldwell, T. S.; Chan, Y.-D.; Christofferson, C. D.; Chu, P.-H.; Cuesta, C.; Detwiler, J. A.; Dunagan, C.; Efremenko, Yu.; Ejiri, H.; Fullmer, A.; Galindo-Uribarri, A.; Gilliss, T.; Giovanetti, G. K.; Green, M. P.; Gruszko, J.; Guinn, I. S.; Guiseppe, V. E.; Henning, R.; Hoppe, E. W.; Howe, M. A.; Jasinski, B. R.; Keeter, K. J.; Kidd, M. F.; Konovalov, S. I.; Kouzes, R. T.; Leon, J.; Lopez, A. M.; MacMullin, J.; Martin, R. D.; Massarczyk, R.; Meijer, S. J.; Mertens, S.; Orrell, J. L.; O'Shaughnessy, C.; Poon, A. W. P.; Radford, D. C.; Rager, J.; Rielage, K.; Robertson, R. G. H.; Romero-Romero, E.; Shanks, B.; Shirchenko, M.; Suriano, A. M.; Tedeschi, D.; Trimble, J. E.; Varner, R. L.; Vasilyev, S.; Vetter, K.; Vorren, K.; White, B. R.; Wilkerson, J. F.; Wiseman, C.; Xu, W.; Yakushev, E.; Yu, C.-H.; Yumatov, V.; Zhitnikov, I.

    2017-09-01

    Neutrinoless double-beta decay searches seek to determine the nature of neutrinos, the existence of a lepton violating process, and the effective Majorana neutrino mass. The Majorana Collaboration is assembling an array of high purity Ge detectors to search for neutrinoless double-beta decay in 76Ge. The Majorana Demonstrator is composed of 44.8 kg (29.7 kg enriched in 76Ge) of Ge detectors in total, split between two modules contained in a low background shield at the Sanford Underground Research Facility in Lead, South Dakota. The initial goals of the Demonstrator are to establish the required background and scalability of a Ge-based, next-generation, tonne-scale experiment. Following a commissioning run that began in 2015, the first detector module started physics data production in early 2016. We will discuss initial results of the Module 1 commissioning and first physics run, as well as the status and potential physics reach of the full Majorana Demonstrator experiment. The collaboration plans to complete the assembly of the second detector module by mid-2016 to begin full data production with the entire array.

  4. Recent Results from the MAJORANA DEMONSTRATOR

    NASA Astrophysics Data System (ADS)

    Gilliss, T.; Alvis, S. I.; Arnquist, I. J.; Avignone, F. T.; Barabash, A. S.; Barton, C. J.; Bertrand, F. E.; Bode, T.; Brudanin, V.; Busch, M.; Buuck, M.; Caldwell, T. S.; Chan, Y.-D.; Christofferson, C. D.; Chu, P.-H.; Cuesta, C.; Detwiler, J. A.; Dunagan, C.; Efremenko, Yu; Ejiri, H.; Elliott, S. R.; Giovanetti, G. K.; Green, M. P.; Gruszko, J.; Guinn, I. S.; Guiseppe, V. E.; Haufe, C. R.; Hehn, L.; Henning, R.; Hoppe, E. W.; Howe, M. A.; Keeter, K. J.; Kidd, M. F.; Konovalov, S. I.; Kouzes, R. T.; Lopez, A. M.; Martin, R. D.; Massarczyk, R.; Meijer, S. J.; Mertens, S.; Myslik, J.; O’Shaughnessy, C.; Othman, G.; Pettus, W.; Poon, A. W. P.; Radford, D. C.; Rager, J.; Reine, A. L.; Rielage, K.; Robertson, R. G. H.; Ruof, N. W.; Shanks, B.; Shirchenko, M.; Suriano, A. M.; Tedeschi, D.; Varner, R. L.; Vasilyev, S.; Vetter, K.; Vorren, K.; White, B. R.; Wilkerson, J. F.; Wiseman, C.; Xu, W.; Yakushev, E.; Yu, C.-H.; Yumatov, V.; Zhitnikov, I.; Zhu, B. X.

    The MAJORANA Collaboration has completed construction and is now operating an array of high purity Ge detectors searching for neutrinoless double-beta decay (0νββ) in 76Ge. The array, known as the MAJORANA DEMONSTRATOR, is comprised of 44 kg of Ge detectors (30 kg enriched to 88% in 76Ge) installed in an ultra-low background compact shield at the Sanford Underground Research Facility in Lead, South Dakota. The primary goal of the DEMONSTRATOR is to establish a low-background design that can be scaled to a next-generation tonne-scale experiment. This work reports initial background levels in the 0νββ region of interest. Also presented are recent physics results leveraging P-type point-contact detectors with sub-keV energy thresholds to search for physics beyond the Standard Model; first results from searches for bosonic dark matter, solar axions, Pauli exclusion principle violation, and electron decay have been published. Finally, this work discusses the proposed tonne-scale 76Ge 0νββ LEGEND experiment.

  5. Results from SMAP Validation Experiments 2015 and 2016

    NASA Astrophysics Data System (ADS)

    Colliander, A.; Jackson, T. J.; Cosh, M. H.; Misra, S.; Crow, W.; Powers, J.; Wood, E. F.; Mohanty, B.; Judge, J.; Drewry, D.; McNairn, H.; Bullock, P.; Berg, A. A.; Magagi, R.; O'Neill, P. E.; Yueh, S. H.

    2017-12-01

    NASA's Soil Moisture Active Passive (SMAP) mission was launched in January 2015. The objective of the mission is global mapping of soil moisture and freeze/thaw state. Well-characterized sites with calibrated in situ soil moisture measurements are used to determine the quality of the soil moisture data products; these sites are designated as core validation sites (CVS). To support the CVS-based validation, airborne field experiments are used to provide high-fidelity validation data and to improve the SMAP retrieval algorithms. The SMAP project and NASA coordinated airborne field experiments at three CVS locations in 2015 and 2016. SMAP Validation Experiment 2015 (SMAPVEX15) was conducted around the Walnut Gulch CVS in Arizona in August, 2015. SMAPVEX16 was conducted at the South Fork CVS in Iowa and Carman CVS in Manitoba, Canada from May to August 2016. The airborne PALS (Passive Active L-band Sensor) instrument mapped all experiment areas several times resulting in 30 coincidental measurements with SMAP. The experiments included intensive ground sampling regime consisting of manual sampling and augmentation of the CVS soil moisture measurements with temporary networks of soil moisture sensors. Analyses using the data from these experiments have produced various results regarding the SMAP validation and related science questions. The SMAPVEX15 data set has been used for calibration of a hyper-resolution model for soil moisture product validation; development of a multi-scale parameterization approach for surface roughness, and validation of disaggregation of SMAP soil moisture with optical thermal signal. The SMAPVEX16 data set has been already used for studying the spatial upscaling within a pixel with highly heterogeneous soil texture distribution; for understanding the process of radiative transfer at plot scale in relation to field scale and SMAP footprint scale over highly heterogeneous vegetation distribution; for testing a data fusion based soil moisture

  6. V-SUIT Model Validation Using PLSS 1.0 Test Results

    NASA Technical Reports Server (NTRS)

    Olthoff, Claas

    2015-01-01

    The dynamic portable life support system (PLSS) simulation software Virtual Space Suit (V-SUIT) has been under development at the Technische Universitat Munchen since 2011 as a spin-off from the Virtual Habitat (V-HAB) project. The MATLAB(trademark)-based V-SUIT simulates space suit portable life support systems and their interaction with a detailed and also dynamic human model, as well as the dynamic external environment of a space suit moving on a planetary surface. To demonstrate the feasibility of a large, system level simulation like V-SUIT, a model of NASA's PLSS 1.0 prototype was created. This prototype was run through an extensive series of tests in 2011. Since the test setup was heavily instrumented, it produced a wealth of data making it ideal for model validation. The implemented model includes all components of the PLSS in both the ventilation and thermal loops. The major components are modeled in greater detail, while smaller and ancillary components are low fidelity black box models. The major components include the Rapid Cycle Amine (RCA) CO2 removal system, the Primary and Secondary Oxygen Assembly (POS/SOA), the Pressure Garment System Volume Simulator (PGSVS), the Human Metabolic Simulator (HMS), the heat exchanger between the ventilation and thermal loops, the Space Suit Water Membrane Evaporator (SWME) and finally the Liquid Cooling Garment Simulator (LCGS). Using the created model, dynamic simulations were performed using same test points also used during PLSS 1.0 testing. The results of the simulation were then compared to the test data with special focus on absolute values during the steady state phases and dynamic behavior during the transition between test points. Quantified simulation results are presented that demonstrate which areas of the V-SUIT model are in need of further refinement and those that are sufficiently close to the test results. Finally, lessons learned from the modelling and validation process are given in combination

  7. Initial Results from the Majorana Demonstrator

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Elliott, S. R.; Abgrall, N.; Arnquist, I. J.

    Neutrinoless double-beta decay searches seek to determine the nature of neutrinos, the existence of a lepton violating process, and the eective Majorana neutrino mass. The Majorana Collaboration is assembling an array of high purity Ge detectors to search for neutrinoless double-beta decay in 76Ge. The Majorana Demonstrator is composed of 44.8 kg (29.7 kg enriched in 76Ge) of Ge detectors in total, split between two modules contained in a low background shield at the Sanford Underground Research Facility in Lead, South Dakota. The initial goals of the Demonstrator are to establish the required background and scalability of a Ge-based, next-generation,more » tonne-scale experiment. Following a commissioning run that began in 2015, the rst detector module started physics data production in early 2016. We will discuss initial results of the Module 1 commissioning and rst physics run, as well as the status and potential physics reach of the full Majorana Demonstrator experiment. The collaboration plans to complete the assembly of the second detector module by mid-2016 to begin full data production with the entire array.« less

  8. Strategic Defense Initiative Demonstration/Validation Program Environmental Assessment. Exoatmospheric Reentry Vehicle Interception System (ERIS),

    DTIC Science & Technology

    1987-08-01

    proceed to Demonstration/Validation for ERIS vould not preclude other technologies, nor vould it mandate the eventual Full-Scale Development or Production ...Full-Scale Development, and Production /Deployment. These four stages are separated by three major decision points (Milestones I, II, and III). Prior...percent facility population increase would require increased power plant gener- ating capacity. One concern is the nitrogen oxide emissions which is

  9. External Validity of the New York University Caregiver Intervention: Key Caregiver Outcomes Across Multiple Demonstration Projects.

    PubMed

    Fauth, Elizabeth B; Jackson, Mark A; Walberg, Donna K; Lee, Nancy E; Easom, Leisa R; Alston, Gayle; Ramos, Angel; Felten, Kristen; LaRue, Asenath; Mittelman, Mary

    2017-06-01

    The Administration on Aging funded six New York University Caregiver Intervention (NYUCI) demonstration projects, a counseling/support intervention targeting dementia caregivers and families. Three sites (Georgia, Utah, Wisconsin) pooled data to inform external validity in nonresearch settings. This study (a) assesses collective changes over time, and (b) compares outcomes across sites on caregiver burden, depressive symptoms, satisfaction with social support, family conflict, and quality of life. Data included baseline/preintervention ( N = 294) and follow-up visits (approximately 4, 8, 12 months). Linear mixed models showed that social support satisfaction increased ( p < .05) and family conflict decreased ( p < .05; Cohen's d = 0.49 and 0.35, respectively). Marginally significant findings emerged for quality of life increases ( p = .05) and burden decreases ( p < .10). Depressive symptoms remained stable. Slopes did not differ much by site. NYUCI demonstrated external validity in nonresearch settings across diverse caregiver samples.

  10. 42 CFR 476.84 - Changes as a result of DRG validation.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... 42 Public Health 4 2014-10-01 2014-10-01 false Changes as a result of DRG validation. 476.84... DRG validation. A provider or practitioner may obtain a review by a QIO under part 473 of this chapter... result of QIO validation activities. ...

  11. Lunar Water Resource Demonstration (LWRD) Test Results

    NASA Technical Reports Server (NTRS)

    Muscatello, Anthony C.; Captain, Janine E.; Quinn, Jacqueline W.; Gibson, Tracy L.; Perusich, Stephen A.; Weis, Kyle H.

    2009-01-01

    NASA has undertaken the In-Situ Resource Utilization (lSRU) project called RESOLVE (Regolith and Environment Science & Oxygen and Lunar Volatile Extraction). This project is an Earth-based lunar precursor demonstration of a system that could be sent to explore permanently shadowed polar lunar craters, where it would drill into regolith, quantify the volatiles that are present, and extract oxygen by hydrogen reduction of iron oxides. The RESOLVE chemical processing system was mounted within the CMU rover "Scarab" and successfully demonstrated on Hawaii's Mauna Kea volcano in November 2008. This technology could be used on Mars as well. As described at the 2008 Mars Society Convention, the Lunar Water Resource Demonstration (LWRD) supports the objectives of the RESOLVE project by capturing and quantifying water and hydrogen released by regolith upon heating. Field test results for the quantification of water using LWRD showed that the volcanic ash (tephra) samples contained 0.15-0.41% water, in agreement with GC water measurements. Reduction of the RH in the surge tank to near zero during recirculation show that the water is captured by the water beds as desired. The water can be recovered by heating the Water Beds to 230 C or higher. Test results for the capture and quantification of pure hydrogen have shown that over 90% of the hydrogen can be captured and 98% of the absorbed hydrogen can be recovered upon heating the hydride to 400 C and desorbing the hydrogen several times into the evacuated surge tank. Thus, the essential requirement of capturing hydrogen and recovering it has been demonstrated. ,

  12. Multi-Evaporator Miniature Loop Heat Pipe for Small Spacecraft Thermal Control. Part 2; Validation Results

    NASA Technical Reports Server (NTRS)

    Ku, Jentung; Ottenstein, Laura; Douglas, Donya; Hoang, Triem

    2010-01-01

    Under NASA s New Millennium Program Space Technology 8 (ST 8) Project, Goddard Space Fight Center has conducted a Thermal Loop experiment to advance the maturity of the Thermal Loop technology from proof of concept to prototype demonstration in a relevant environment , i.e. from a technology readiness level (TRL) of 3 to a level of 6. The thermal Loop is an advanced thermal control system consisting of a miniature loop heat pipe (MLHP) with multiple evaporators and multiple condensers designed for future small system applications requiring low mass, low power, and compactness. The MLHP retains all features of state-of-the-art loop heat pipes (LHPs) and offers additional advantages to enhance the functionality, performance, versatility, and reliability of the system. An MLHP breadboard was built and tested in the laboratory and thermal vacuum environments for the TRL 4 and TRL 5 validations, respectively, and an MLHP proto-flight unit was built and tested in a thermal vacuum chamber for the TRL 6 validation. In addition, an analytical model was developed to simulate the steady state and transient behaviors of the MLHP during various validation tests. The MLHP demonstrated excellent performance during experimental tests and the analytical model predictions agreed very well with experimental data. All success criteria at various TRLs were met. Hence, the Thermal Loop technology has reached a TRL of 6. This paper presents the validation results, both experimental and analytical, of such a technology development effort.

  13. DEMONSTRATION OF WELLMAN-LORD/ALLIED CHEMICAL FGD TECHNOLOGY: DEMONSTRATION TEST SECOND YEAR RESULTS

    EPA Science Inventory

    The report gives results of an evaluation of the performance (over a 2-year period) of a full-scale flue gas desulfurization (FGD) unit to demonstrate the Wellman-Lord/Allied Chemical process. The process is regenerable, employing sodium sulfite wet scrubbing, thermal regeneratio...

  14. Validation of microbiological testing in cardiovascular tissue banks: results of a quality round trial.

    PubMed

    de By, Theo M M H; McDonald, Carl; Süßner, Susanne; Davies, Jill; Heng, Wee Ling; Jashari, Ramadan; Bogers, Ad J J C; Petit, Pieter

    2017-11-01

    Surgeons needing human cardiovascular tissue for implantation in their patients are confronted with cardiovascular tissue banks that use different methods to identify and decontaminate micro-organisms. To elucidate these differences, we compared the quality of processing methods in 20 tissue banks and 1 reference laboratory. We did this to validate the results for accepting or rejecting tissue. We included the decontamination methods used and the influence of antibiotic cocktails and residues with results and controls. The minor details of the processes were not included. To compare the outcomes of microbiological testing and decontamination methods of heart valve allografts in cardiovascular tissue banks, an international quality round was organized. Twenty cardiovascular tissue banks participated in this quality round. The quality round method was validated first and consisted of sending purposely contaminated human heart valve tissue samples with known micro-organisms to the participants. The participants identified the micro-organisms using their local decontamination methods. Seventeen of the 20 participants correctly identified the micro-organisms; if these samples were heart valves to be released for implantation, 3 of the 20 participants would have decided to accept their result for release. Decontamination was shown not to be effective in 13 tissue banks because of growth of the organisms after decontamination. Articles in the literature revealed that antibiotics are effective at 36°C and not, or less so, at 2-8°C. The decontamination procedure, if it is validated, will ensure that the tissue contains no known micro-organisms. This study demonstrates that the quality round method of sending contaminated tissues and assessing the results of the microbiological cultures is an effective way of validating the processes of tissue banks. Only when harmonization, based on validated methods, has been achieved, will surgeons be able to fully rely on the methods

  15. A mechanistic model for electricity consumption on dairy farms: definition, validation, and demonstration.

    PubMed

    Upton, J; Murphy, M; Shalloo, L; Groot Koerkamp, P W G; De Boer, I J M

    2014-01-01

    Our objective was to define and demonstrate a mechanistic model that enables dairy farmers to explore the impact of a technical or managerial innovation on electricity consumption, associated CO2 emissions, and electricity costs. We, therefore, (1) defined a model for electricity consumption on dairy farms (MECD) capable of simulating total electricity consumption along with related CO2 emissions and electricity costs on dairy farms on a monthly basis; (2) validated the MECD using empirical data of 1yr on commercial spring calving, grass-based dairy farms with 45, 88, and 195 milking cows; and (3) demonstrated the functionality of the model by applying 2 electricity tariffs to the electricity consumption data and examining the effect on total dairy farm electricity costs. The MECD was developed using a mechanistic modeling approach and required the key inputs of milk production, cow number, and details relating to the milk-cooling system, milking machine system, water-heating system, lighting systems, water pump systems, and the winter housing facilities as well as details relating to the management of the farm (e.g., season of calving). Model validation showed an overall relative prediction error (RPE) of less than 10% for total electricity consumption. More than 87% of the mean square prediction error of total electricity consumption was accounted for by random variation. The RPE values of the milk-cooling systems, water-heating systems, and milking machine systems were less than 20%. The RPE values for automatic scraper systems, lighting systems, and water pump systems varied from 18 to 113%, indicating a poor prediction for these metrics. However, automatic scrapers, lighting, and water pumps made up only 14% of total electricity consumption across all farms, reducing the overall impact of these poor predictions. Demonstration of the model showed that total farm electricity costs increased by between 29 and 38% by moving from a day and night tariff to a flat

  16. Simulated Driving Assessment (SDA) for teen drivers: results from a validation study.

    PubMed

    McDonald, Catherine C; Kandadai, Venk; Loeb, Helen; Seacrist, Thomas S; Lee, Yi-Ching; Winston, Zachary; Winston, Flaura K

    2015-06-01

    Driver error and inadequate skill are common critical reasons for novice teen driver crashes, yet few validated, standardised assessments of teen driving skills exist. The purpose of this study is to evaluate the construct and criterion validity of a newly developed Simulated Driving Assessment (SDA) for novice teen drivers. The SDA's 35 min simulated drive incorporates 22 variations of the most common teen driver crash configurations. Driving performance was compared for 21 inexperienced teens (age 16-17 years, provisional license ≤90 days) and 17 experienced adults (age 25-50 years, license ≥5 years, drove ≥100 miles per week, no collisions or moving violations ≤3 years). SDA driving performance (Error Score) was based on driving safety measures derived from simulator and eye-tracking data. Negative driving outcomes included simulated collisions or run-off-the-road incidents. A professional driving evaluator/instructor (DEI Score) reviewed videos of SDA performance. The SDA demonstrated construct validity: (1) teens had a higher Error Score than adults (30 vs. 13, p=0.02); (2) For each additional error committed, the RR of a participant's propensity for a simulated negative driving outcome increased by 8% (95% CI 1.05 to 1.10, p<0.01). The SDA-demonstrated criterion validity: Error Score was correlated with DEI Score (r=-0.66, p<0.001). This study supports the concept of validated simulated driving tests like the SDA to assess novice driver skill in complex and hazardous driving scenarios. The SDA, as a standard protocol to evaluate teen driver performance, has the potential to facilitate screening and assessment of teen driving readiness and could be used to guide targeted skill training. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://group.bmj.com/group/rights-licensing/permissions.

  17. 10 CFR 26.139 - Reporting initial validity and drug test results.

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... 10 Energy 1 2014-01-01 2014-01-01 false Reporting initial validity and drug test results. 26.139... § 26.139 Reporting initial validity and drug test results. (a) The licensee testing facility shall... permitted under § 26.75(h), positive test results from initial drug tests at the licensee testing facility...

  18. 10 CFR 26.139 - Reporting initial validity and drug test results.

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... 10 Energy 1 2012-01-01 2012-01-01 false Reporting initial validity and drug test results. 26.139... § 26.139 Reporting initial validity and drug test results. (a) The licensee testing facility shall... permitted under § 26.75(h), positive test results from initial drug tests at the licensee testing facility...

  19. 42 CFR 476.84 - Changes as a result of DRG validation.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 42 Public Health 4 2010-10-01 2010-10-01 false Changes as a result of DRG validation. 476.84... § 476.84 Changes as a result of DRG validation. A provider or practitioner may obtain a review by a QIO under part 473 of this chapter for changes in diagnostic and procedural coding that resulted in a change...

  20. 42 CFR 476.84 - Changes as a result of DRG validation.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... 42 Public Health 4 2012-10-01 2012-10-01 false Changes as a result of DRG validation. 476.84... § 476.84 Changes as a result of DRG validation. A provider or practitioner may obtain a review by a QIO under part 473 of this chapter for changes in diagnostic and procedural coding that resulted in a change...

  1. 42 CFR 476.84 - Changes as a result of DRG validation.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... 42 Public Health 4 2013-10-01 2013-10-01 false Changes as a result of DRG validation. 476.84... § 476.84 Changes as a result of DRG validation. A provider or practitioner may obtain a review by a QIO under part 473 of this chapter for changes in diagnostic and procedural coding that resulted in a change...

  2. 42 CFR 476.84 - Changes as a result of DRG validation.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 42 Public Health 4 2011-10-01 2011-10-01 false Changes as a result of DRG validation. 476.84... § 476.84 Changes as a result of DRG validation. A provider or practitioner may obtain a review by a QIO under part 473 of this chapter for changes in diagnostic and procedural coding that resulted in a change...

  3. The NASA Aircraft VOrtex Spacing System (AVOSS): Concept Demonstration Results and Future Direction

    NASA Technical Reports Server (NTRS)

    Rutishauser, David K.; OConnor, Cornelius J.

    2004-01-01

    Since the late 1990s the national airspace system has been recognized as approaching a capacity crisis. In the light of this condition, industry, government, user organizations, and educational institutions have been working on procedural and technological solutions to the problem. One aspect of system operations that holds potential for improvement is the separation criteria applied to aircraft for wake vortex avoidance. These criteria, applied when operations are conducted under instrument flight rules (IFR), were designed to represent safe spacing under weather conditions conducive to the longest wake hazards. It is well understood that wake behavior is dependent on meteorological conditions as well as the physical parameters of the generating aircraft. Under many ambient conditions, such as moderate crosswinds or turbulence, wake hazard durations are substantially reduced. To realize this reduction NASA has developed a proof-of-concept Aircraft VOrtex Spacing System (AVOSS). Successfully demonstrated in a realtime field demonstration during July 2000 at the Dallas Ft. Worth International Airport (DFW), AVOSS is a novel integration of weather sensors, wake sensors, and analytical wake prediction algorithms. AVOSS provides dynamic wake separation criteria that are a function of the ambient weather conditions for a particular airport, and the predicted wake behavior under those conditions. Wake sensing subsystems provide safety checks and validation for the predictions. The AVOSS was demonstrated in shadow mode; no actual spacing changes were applied to aircraft. This paper briefly reviews the system architecture and operation, reports the latest performance results from the DFW deployment, and describes the future direction of the project.

  4. 42 CFR 478.15 - QIO review of changes resulting from DRG validation.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... 42 Public Health 4 2014-10-01 2014-10-01 false QIO review of changes resulting from DRG validation... review of changes resulting from DRG validation. (a) General rules. (1) A provider or practitioner... validation under section 1866(a)(1)(F) of the Act is entitled to a review of that change if— (i) The change...

  5. 42 CFR 478.15 - QIO review of changes resulting from DRG validation.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... 42 Public Health 4 2013-10-01 2013-10-01 false QIO review of changes resulting from DRG validation... review of changes resulting from DRG validation. (a) General rules. (1) A provider or practitioner... validation under section 1866(a)(1)(F) of the Act is entitled to a review of that change if— (i) The change...

  6. 42 CFR 478.15 - QIO review of changes resulting from DRG validation.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 42 Public Health 4 2011-10-01 2011-10-01 false QIO review of changes resulting from DRG validation... review of changes resulting from DRG validation. (a) General rules. (1) A provider or practitioner... validation under section 1866(a)(1)(F) of the Act is entitled to a review of that change if— (i) The change...

  7. 42 CFR 478.15 - QIO review of changes resulting from DRG validation.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... 42 Public Health 4 2012-10-01 2012-10-01 false QIO review of changes resulting from DRG validation... review of changes resulting from DRG validation. (a) General rules. (1) A provider or practitioner... validation under section 1866(a)(1)(F) of the Act is entitled to a review of that change if— (i) The change...

  8. 42 CFR 493.571 - Disclosure of accreditation, State and CMS validation inspection results.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... validation inspection results. 493.571 Section 493.571 Public Health CENTERS FOR MEDICARE & MEDICAID SERVICES... Program § 493.571 Disclosure of accreditation, State and CMS validation inspection results. (a... licensure program, in accordance with State law. (c) CMS validation inspection results. CMS may disclose the...

  9. 42 CFR 493.571 - Disclosure of accreditation, State and CMS validation inspection results.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... validation inspection results. 493.571 Section 493.571 Public Health CENTERS FOR MEDICARE & MEDICAID SERVICES... Program § 493.571 Disclosure of accreditation, State and CMS validation inspection results. (a... licensure program, in accordance with State law. (c) CMS validation inspection results. CMS may disclose the...

  10. 42 CFR 493.571 - Disclosure of accreditation, State and CMS validation inspection results.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... validation inspection results. 493.571 Section 493.571 Public Health CENTERS FOR MEDICARE & MEDICAID SERVICES... Program § 493.571 Disclosure of accreditation, State and CMS validation inspection results. (a... licensure program, in accordance with State law. (c) CMS validation inspection results. CMS may disclose the...

  11. 42 CFR 493.571 - Disclosure of accreditation, State and CMS validation inspection results.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... validation inspection results. 493.571 Section 493.571 Public Health CENTERS FOR MEDICARE & MEDICAID SERVICES... Program § 493.571 Disclosure of accreditation, State and CMS validation inspection results. (a... licensure program, in accordance with State law. (c) CMS validation inspection results. CMS may disclose the...

  12. 42 CFR 493.571 - Disclosure of accreditation, State and CMS validation inspection results.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... validation inspection results. 493.571 Section 493.571 Public Health CENTERS FOR MEDICARE & MEDICAID SERVICES... Program § 493.571 Disclosure of accreditation, State and CMS validation inspection results. (a... licensure program, in accordance with State law. (c) CMS validation inspection results. CMS may disclose the...

  13. 10 CFR 26.139 - Reporting initial validity and drug test results.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... 10 Energy 1 2011-01-01 2011-01-01 false Reporting initial validity and drug test results. 26.139 Section 26.139 Energy NUCLEAR REGULATORY COMMISSION FITNESS FOR DUTY PROGRAMS Licensee Testing Facilities § 26.139 Reporting initial validity and drug test results. (a) The licensee testing facility shall...

  14. 10 CFR 26.139 - Reporting initial validity and drug test results.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... 10 Energy 1 2010-01-01 2010-01-01 false Reporting initial validity and drug test results. 26.139 Section 26.139 Energy NUCLEAR REGULATORY COMMISSION FITNESS FOR DUTY PROGRAMS Licensee Testing Facilities § 26.139 Reporting initial validity and drug test results. (a) The licensee testing facility shall...

  15. 10 CFR 26.139 - Reporting initial validity and drug test results.

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... 10 Energy 1 2013-01-01 2013-01-01 false Reporting initial validity and drug test results. 26.139 Section 26.139 Energy NUCLEAR REGULATORY COMMISSION FITNESS FOR DUTY PROGRAMS Licensee Testing Facilities § 26.139 Reporting initial validity and drug test results. (a) The licensee testing facility shall...

  16. The Majorana Demonstrator Status and Preliminary Results

    NASA Astrophysics Data System (ADS)

    Yu, C.-H.; Alvis, S. I.; Arnquist, I. J.; Avignone, F. T.; Barabash, A. S.; Barton, C. J.; Bertrand, F. E.; Bode, T.; Brudanin, V.; Busch, M.; Buuck, M.; Caldwell, T. S.; Chan, Y.-D.; Christofferson, C. D.; Chu, P.-H.; Cuesta, C.; Detwiler, J. A.; Dunagan, C.; Efremenko, Yu; Ejiri, H.; Elliott, S. R.; Gilliss, T.; Giovanetti, G. K.; Green, M.; Gruszko, J.; Guinn, I. S.; Guiseppe, V. E.; Haufe, C. R.; Hehn, L.; Henning, R.; Hoppe, E. W.; Howe, M. A.; Keeter, K. J.; Kidd, M. F.; Konovalov, S. I.; Kouzes, R. T.; Lopez, A. M.; Martin, R. D.; Massarczyk, R.; Meijer, S. J.; Mertens, S.; Myslik, J.; Othman, G.; Pettus, W.; Poon, A. W. P.; Radford, D. C.; Rager, J.; Reine, A. L.; Rielage, K.; Ruof, N. W.; Shanks, B.; Shirchenko, M.; Suriano, A. M.; Tedeschi, D.; Varner, R. L.; Vasilyev, S.; Vetter, K.; Vorren, K.; White, B. R.; Wilkerson, J. F.; Wiseman, C.; Xu, W.; Yakushev, E.; Yumatov, V.; Zhitnikov, I.; Zhu, B. Z.

    2018-05-01

    The MAJORANA Collaboration is using an array of high-purity Ge detectors to search for neutrinoless double-beta decay in 76Ge. Searches for neutrinoless double-beta decay are understood to be the only viable experimental method for testing the Majorana nature of the neutrino. Observation of this decay would imply violation of lepton number, that neutrinos are Majorana in nature, and provide information on the neutrino mass. The MAJORANA DEMONSTRATOR comprises 44.1 kg of p-type point-contact Ge detectors (29.7 kg enriched in 76Ge) surrounded by a low-background shield system. The experiment achieved a high efficiency of converting raw Ge material to detectors and an unprecedented detector energy resolution of 2.5 keV FWHM at Qββ. The MAJORANA collaboration began taking physics data in 2016. This paper summarizes key construction aspects of the Demonstrator and shows preliminary results from initial data.

  17. Controlled Hydrogen Fleet and Infrastructure Demonstration and Validation Project Final Technical Report

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Verma, Puneet; Casey, Dan

    This report summarizes the work conducted under U.S. Department of Energy (US DOE) contract DE-FC36-04GO14286 by Chevron Technology Ventures (CTV, a division of Chevron U.S.A., Inc.), Hyundai Motor Company (HMC), and UTC Power (UTCP, a United Technologies company) to validate hydrogen (H2) infrastructure technology and fuel cell hybrid vehicles. Chevron established hydrogen filling stations at fleet operator sites using multiple technologies for on-site hydrogen generation, storage, and dispensing. CTV constructed five demonstration stations to support a vehicle fleet of 33 fuel cell passenger vehicles, eight internal combustion engine (ICE) vehicles, three fuel cell transit busses, and eight internal combustion enginemore » shuttle busses. Stations were operated between 2005 and 2010. HMC introduced 33 fuel cell hybrid electric vehicles (FCHEV) in the course of the project. Generation I included 17 vehicles that used UTCP fuel cell power plants and operated at 350 bar. Generation II included 16 vehicles that had upgraded UTC fuel cell power plants and demonstrated options such as the use of super-capacitors and operation at 700 bar. All 33 vehicles used the Hyundai Tucson sports utility vehicle (SUV) platform. Fleet operators demonstrated commercial operation of the vehicles in three climate zones (hot, moderate, and cold) and for various driving patterns. Fleet operators were Southern California Edison (SCE), AC Transit (of Oakland, California), Hyundai America Technical Center Inc. (HATCI), and the U.S. Army Tank Automotive Research, Development and Engineering Center (TARDEC, in a site agreement with Selfridge Army National Guard Base in Selfridge, Michigan).« less

  18. Crew station research and development facility training for the light helicopter demonstration/validation program

    NASA Technical Reports Server (NTRS)

    Matsumoto, Joy Hamerman; Rogers, Steven; Mccauley, Michael; Salinas, AL

    1992-01-01

    The U.S. Army Crew Station Research and Development Branch (CSRDB) of the Aircraft Simulation Division (AVSCOM) was tasked by the Light Helicopter Program Manager (LH-PM) to provide training to Army personnel in advanced aircraft simulation technology. The purpose of this training was to prepare different groups of pilots to support and evaluate two contractor simulation efforts during the Demonstration/Validation (DEM/VAL) phase of the LH program. The personnel in the CSRDB developed mission oriented training programs to accomplish the objectives, conduct the programs, and provide guidance to army personnel and support personnel throughout the DEM/VAL phase.

  19. The Majorana Demonstrator Status and Preliminary Results

    DOE PAGES

    Yu, C. -H.; Alvis, S. I.; Arnquist, I. J.; ...

    2018-01-01

    The MAJORANA Collaboration is using an array of high-purity Ge detectors to search for neutrinoless double-beta decay in 76Ge. Searches for neutrinoless double-beta decay are understood to be the only viable experimental method for testing the Majorana nature of the neutrino. Observation of this decay would imply violation of lepton number, that neutrinos are Majorana in nature, and provide information on the neutrino mass. The MAJORANA DEMONSTRATOR comprises 44.1 kg of p-type point-contact Ge detectors (29.7 kg enriched in 76Ge) surrounded by a low-background shield system. The experiment achieved a high efficiency of converting raw Ge material to detectors andmore » an unprecedented detector energy resolution of 2.5 keV FWHM at Q ββ. The MAJORANA collaboration began taking physics data in 2016. Here, this paper summarizes key construction aspects of the Demonstrator and shows preliminary results from initial data.« less

  20. The Majorana Demonstrator Status and Preliminary Results

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Yu, C. -H.; Alvis, S. I.; Arnquist, I. J.

    The MAJORANA Collaboration is using an array of high-purity Ge detectors to search for neutrinoless double-beta decay in 76Ge. Searches for neutrinoless double-beta decay are understood to be the only viable experimental method for testing the Majorana nature of the neutrino. Observation of this decay would imply violation of lepton number, that neutrinos are Majorana in nature, and provide information on the neutrino mass. The MAJORANA DEMONSTRATOR comprises 44.1 kg of p-type point-contact Ge detectors (29.7 kg enriched in 76Ge) surrounded by a low-background shield system. The experiment achieved a high efficiency of converting raw Ge material to detectors andmore » an unprecedented detector energy resolution of 2.5 keV FWHM at Q ββ. The MAJORANA collaboration began taking physics data in 2016. Here, this paper summarizes key construction aspects of the Demonstrator and shows preliminary results from initial data.« less

  1. Results and current status of the NPARC alliance validation effort

    NASA Technical Reports Server (NTRS)

    Towne, Charles E.; Jones, Ralph R.

    1996-01-01

    The NPARC Alliance is a partnership between the NASA Lewis Research Center (LeRC) and the USAF Arnold Engineering Development Center (AEDC) dedicated to the establishment of a national CFD capability, centered on the NPARC Navier-Stokes computer program. The three main tasks of the Alliance are user support, code development, and validation. The present paper is a status report on the validation effort. It describes the validation approach being taken by the Alliance. Representative results are presented for laminar and turbulent flat plate boundary layers, a supersonic axisymmetric jet, and a glancing shock/turbulent boundary layer interaction. Cases scheduled to be run in the future are also listed. The archive of validation cases is described, including information on how to access it via the Internet.

  2. Demonstration/Validation of Environmentally-Preferable Coatings for Launch Facilities

    NASA Technical Reports Server (NTRS)

    Lewis, Pattie

    2011-01-01

    Kennedy Space Center (KSC) is responsible for a number of facilities/structures with metallic structural and non-structural components in a highly corrosive environment. Metals require periodic maintenance activity to guard against the insidious effects of corrosion and thus ensure that structures meet or exceed design or performance life. The standard practice for protecting metallic substrates in atmospheric environments is the application of an applied coating system. Applied coating systems work via a variety of methods (barrier, galvanic and/or inhibitor) and adhere to the substrate through a combination of chemical and physical bonds. Maintenance at KSC and other NASA Centers is governed by NASA-STD-50088 (Protective Coating of Carbon Steel, Stainless Steel, and Aluminum on Launch Structures, Facilities, and Ground Support Equipment) which establishes practices for the protective coating of ground support equipment and related facilities used by or for NASA programs and projects. The Standard is for the design of non-flight hardware used to support the operations of receiving, transportation, handling, assembly, inspection, test, checkout, service, and launch of space vehicles and payloads at NASA launch, landing, or retrieval sites. These criteria and practices contained within the Standard may be used for items used at the manufacturing, development, and test sites upstream of the launch, landing, or retrieval sites. The objective of this effort is to demonstrate and validate environmentally-preferable alternatives in accordance with NASA-STD-50088 and KSC requirements which can then be added to the Approved Products List. This Test Protocol contains the critical requirements and tests necessary to qualify alternatives for structural steel applications. These tests were derived from engineering, performance, and operational impact (supportability) requirements defined by a consensus of KSC participants. A Test Report will document the results of the testing

  3. Cooperative Collision Avoidance Technology Demonstration Data Analysis Report

    NASA Technical Reports Server (NTRS)

    2007-01-01

    This report details the National Aeronautics and Space Administration (NASA) Access 5 Project Office Cooperative Collision Avoidance (CCA) Technology Demonstration for unmanned aircraft systems (UAS) conducted from 21 to 28 September 2005. The test platform chosen for the demonstration was the Proteus Optionally Piloted Vehicle operated by Scaled Composites, LLC, flown out of the Mojave Airport, Mojave, CA. A single intruder aircraft, a NASA Gulf stream III, was used during the demonstration to execute a series of near-collision encounter scenarios. Both aircraft were equipped with Traffic Alert and Collision Avoidance System-II (TCAS-II) and Automatic Dependent Surveillance Broadcast (ADS-B) systems. The objective of this demonstration was to collect flight data to support validation efforts for the Access 5 CCA Work Package Performance Simulation and Systems Integration Laboratory (SIL). Correlation of the flight data with results obtained from the performance simulation serves as the basis for the simulation validation. A similar effort uses the flight data to validate the SIL architecture that contains the same sensor hardware that was used during the flight demonstration.

  4. 42 CFR 478.15 - QIO review of changes resulting from DRG validation.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 42 Public Health 4 2010-10-01 2010-10-01 false QIO review of changes resulting from DRG validation... review of changes resulting from DRG validation. (a) General rules. (1) A provider or practitioner dissatisfied with a change to the diagnostic or procedural coding information made by a QIO as a result of DRG...

  5. Newberry Volcano EGS Demonstration: Plans and Results

    NASA Astrophysics Data System (ADS)

    Cladouhos, T. T.; Petty, S.; Moore, M.; Nordin, Y.; De Rocher, T.; Callahan, O.; Perry, D.

    2012-12-01

    thermo-degradable zonal isolation materials (TZIMs) to temporarily seal off fractures in a geothermal well, allowing for stimulation of secondary and tertiary fracture zones, thus optimizing the injection/production profile of the entire well. TZIMs with ranges of thermal degradation properties have been extensively tested in the lab and two conventional geothermal fields. At Newberry, TZIMs that are stable at 200°C and degrade quickly at 300°C will be used. Third, the project follows a project-specific Induced Seismicity Mitigation Plan (ISMP) to evaluate, monitor for, and mitigate felt induced seismicity. During stimulation, 16 seismic stations, installed within 4 km of the target stimulation zone, monitor microseismicity and growth of the EGS reservoir. Seismicity occurring in undesirable locations or with ground accelerations or magnitudes above agreed thresholds, would result in operational changes to prevent unwanted seismicity, such as the use of TZIMs or lower well head pressures. Results of the Demonstration, shared with the public, geothermal and scientific communities include the real-time microseismicity, injection pressures and flow rates, and final injectivity of the stimulated well.

  6. Validation of a Scalable Solar Sailcraft

    NASA Technical Reports Server (NTRS)

    Murphy, D. M.

    2006-01-01

    The NASA In-Space Propulsion (ISP) program sponsored intensive solar sail technology and systems design, development, and hardware demonstration activities over the past 3 years. Efforts to validate a scalable solar sail system by functional demonstration in relevant environments, together with test-analysis correlation activities on a scalable solar sail system have recently been successfully completed. A review of the program, with descriptions of the design, results of testing, and analytical model validations of component and assembly functional, strength, stiffness, shape, and dynamic behavior are discussed. The scaled performance of the validated system is projected to demonstrate the applicability to flight demonstration and important NASA road-map missions.

  7. Results of a Formal Methods Demonstration Project

    NASA Technical Reports Server (NTRS)

    Kelly, J.; Covington, R.; Hamilton, D.

    1994-01-01

    This paper describes the results of a cooperative study conducted by a team of researchers in formal methods at three NASA Centers to demonstrate FM techniques and to tailor them to critical NASA software systems. This pilot project applied FM to an existing critical software subsystem, the Shuttle's Jet Select subsystem (Phase I of an ongoing study). The present study shows that FM can be used successfully to uncover hidden issues in a highly critical and mature Functional Subsystem Software Requirements (FSSR) specification which are very difficult to discover by traditional means.

  8. Vegetable behavioral tool demonstrates validity with MyPlate vegetable cups and carotenoid and inflammatory biomarkers.

    PubMed

    Townsend, Marilyn S; Shilts, Mical K; Styne, Dennis M; Drake, Christiana; Lanoue, Louise; Woodhouse, Leslie; Allen, Lindsay H

    2016-12-01

    Young children are not meeting recommendations for vegetable intake. Our objective is to provide evidence of validity and reliability for a pictorial vegetable behavioral assessment for use by federally funded community nutrition programs. Parent/child pairs (n=133) from Head Start and the Special Supplemental Nutrition Program for Women, Infants and Children [WIC] provided parent-administered vegetable tools, three child 24-hour diet recalls, child blood sample and measured heights/weights. The 10-item Focus on Veggies scale, with an alpha of .83 and a stability reliability coefficient of .74, was positively related to vegetables in cup equivalents [p≤.05]; dietary intakes of folate, vitamin C, β-carotene, potassium and magnesium [p≤.05-.01]; and soluble fiber [p≤.001]. The child vegetable scores were related to the parent's mediators [p≤.00001] and vegetable behaviors [p≤.00001]. Children's plasma inflammatory markers were negatively related to the 10 item scale [p≤.05] and are indicators of the child's health status. The positive relationship between the serum carotenoid index and a sub-scale of child vegetable behaviors offered additional support for criterion validity [p≤.05]. Finally, the inverse relationship of BMI-for-age percentile one year post baseline and a sub-scale of child vegetable behaviors supported the predictive validity [p≤.05]. Focus on Veggies, a simple assessment tool, can inform practitioners about the child's health status. A child with a high score, shows a healthful profile with a lower inflammation index, higher carotenoid index, lower BMI and higher vegetable intake. In conclusion, validity of Focus on Veggies has been demonstrated using vegetable cup equivalents and micronutrient intakes, anthropometry and blood biomarkers. Copyright © 2016 Elsevier Ltd. All rights reserved.

  9. Field Demonstration and Validation of a New Device for Measuring Groundwater and Perchlorate Fluxes at IHDIV-NSWC, Indian Head, MD

    DTIC Science & Technology

    2006-07-01

    in bioremediation (such as lactate, citrate, benzoate , phenols, etc). Site Study Objectives • demonstrate and validate the PFM as an innovative...contaminants and alcohol tracers. However, organic acids (e.g., benzoate ) can be used as the PFM resident racers. We modified zeolites and GAC with a...bioremediation (such as lactate, citrate, benzoate , phenols, etc). 1.2. Objectives of the Demonstration The specific objectives of this

  10. Sextant X-Ray Pulsar Navigation Demonstration: Initial On-Orbit Results

    NASA Technical Reports Server (NTRS)

    Mitchell, Jason W.; Winternitz, Luke M.; Hassouneh, Munther A.; Price, Samuel R.; Semper, Sean R.; Yu, Wayne H.; Ray, Paul S.; Wolff, Michael T.; Kerr, Matthew; Wood, Kent S.; hide

    2018-01-01

    The Station Explorer for X-ray Timing and Navigation Technology (SEXTANT) is a technology demonstration enhancement to the Neutron-star Interior Composition Explorer (NICER) mission. SEXTANT will be a first demonstration of in-space, autonomous, X-ray pulsar navigation (XNAV). Navigating using millisecond X-ray pulsars which could provide a GPS-like navigation capability available throughout our Solar System and beyond. NICER is a NASA Astrophysics Explorer Mission of Opportunity to the International Space Station that was launched and installed in June of 2017. During NICER's nominal 18-month base mission, SEXTANT will perform a number of experiments to demonstrate XNAV and advance the technology on a number of fronts. In this work, we review the SEXTANT, its goals, and present early results from SEXTANT experiments conducted in the first six months of operation. With these results, SEXTANT has made significant progress toward meeting its primary and secondary mission goals. We also describe the SEXTANT flight operations, calibration activities, and initial results.

  11. Validation of morphing wing methodologies on an unmanned aerial system and a wind tunnel technology demonstrator

    NASA Astrophysics Data System (ADS)

    Gabor, Oliviu Sugar

    To increase the aerodynamic efficiency of aircraft, in order to reduce the fuel consumption, a novel morphing wing concept has been developed. It consists in replacing a part of the wing upper and lower surfaces with a flexible skin whose shape can be modified using an actuation system placed inside the wing structure. Numerical studies in two and three dimensions were performed in order to determine the gains the morphing system achieves for the case of an Unmanned Aerial System and for a morphing technology demonstrator based on the wing tip of a transport aircraft. To obtain the optimal wing skin shapes in function of the flight condition, different global optimization algorithms were implemented, such as the Genetic Algorithm and the Artificial Bee Colony Algorithm. To reduce calculation times, a hybrid method was created by coupling the population-based algorithm with a fast, gradient-based local search method. Validations were performed with commercial state-of-the-art optimization tools and demonstrated the efficiency of the proposed methods. For accurately determining the aerodynamic characteristics of the morphing wing, two new methods were developed, a nonlinear lifting line method and a nonlinear vortex lattice method. Both use strip analysis of the span-wise wing section to account for the airfoil shape modifications induced by the flexible skin, and can provide accurate results for the wing drag coefficient. The methods do not require the generation of a complex mesh around the wing and are suitable for coupling with optimization algorithms due to the computational time several orders of magnitude smaller than traditional three-dimensional Computational Fluid Dynamics methods. Two-dimensional and three-dimensional optimizations of the Unmanned Aerial System wing equipped with the morphing skin were performed, with the objective of improving its performances for an extended range of flight conditions. The chordwise positions of the internal actuators

  12. Enhanced Flight Termination System (EFTS): Flight Demonstration and Results

    NASA Technical Reports Server (NTRS)

    Tow, David; Arce, Dennis

    2008-01-01

    The Enhanced Flight Termination System (EFTS) program was initiated and propelled due to the inadvertent terminations of Global Hawk and the Strategic Target System and the NASA Inspector General's assessment letter and recommendations regarding the exploration of low-cost, lightweight space COMSEC for FTS. Additionally, the standard analog and high alphabet systems most commonly used in FTS are secure, but not encrypted. A study group was initiated to select and document a robust, affordable, reliable technology that provides encrypted FTS capability. A flight demonstration was conducted to gain experience using EFTS in an operational environment, provide confidence in the use of the EFTS components, integrate EFTS into an existing range infrastructure to demonstrate the scalability of system components, to provide a command controller that generated the EFTS waveform using an existing range infrastructure, and to provide a report documenting the results of the demonstration. The primary goal of the demonstration was to obtain operational experience with EFTS. Areas of operational experience include: mission planning, pre-flight configuration and testing, mission monitoring and recording, vehicle termination, developing mission procedures. and post mission data reduction and other post mission activities. An Advanced Medium-Range Air-to-Air Missile (AMRAAM) was selected to support the EFTS demonstration due to interest in future use of EFTS by the AMRAAM program, familiarity of EFTS by range personnel, and the availability of existing operational environment to support EFTS testing with available program funding. For demonstration purposes, the AMRAAM was successfully terminated using an EFTS receiver and successfully demonstrating EFTS. The EFTS monitoring software with spectrum analyzer and digital graphical display of aircraft, missile, and target were also demonstrated.

  13. Verification and Validation of Adaptive and Intelligent Systems with Flight Test Results

    NASA Technical Reports Server (NTRS)

    Burken, John J.; Larson, Richard R.

    2009-01-01

    F-15 IFCS project goals are: a) Demonstrate Control Approaches that can Efficiently Optimize Aircraft Performance in both Normal and Failure Conditions [A] & [B] failures. b) Advance Neural Network-Based Flight Control Technology for New Aerospace Systems Designs with a Pilot in the Loop. Gen II objectives include; a) Implement and Fly a Direct Adaptive Neural Network Based Flight Controller; b) Demonstrate the Ability of the System to Adapt to Simulated System Failures: 1) Suppress Transients Associated with Failure; 2) Re-Establish Sufficient Control and Handling of Vehicle for Safe Recovery. c) Provide Flight Experience for Development of Verification and Validation Processes for Flight Critical Neural Network Software.

  14. Results and Validation of MODIS Aerosol Retrievals Over Land and Ocean

    NASA Technical Reports Server (NTRS)

    Remer, Lorraine; Einaudi, Franco (Technical Monitor)

    2001-01-01

    The MODerate Resolution Imaging Spectroradiometer (MODIS) instrument aboard the Terra spacecraft has been retrieving aerosol parameters since late February 2000. Initial qualitative checking of the products showed very promising results including matching of land and ocean retrievals at coastlines. Using AERONET ground-based radiometers as our primary validation tool, we have established quantitative validation as well. Our results show that for most aerosol types, the MODIS products fall within the pre-launch estimated uncertainties. Surface reflectance and aerosol model assumptions appear to be sufficiently accurate for the optical thickness retrieval. Dust provides a possible exception, which may be due to non-spherical effects. Over ocean the MODIS products include information on particle size, and these parameters are also validated with AERONET retrievals.

  15. Results and Validation of MODIS Aerosol Retrievals over Land and Ocean

    NASA Technical Reports Server (NTRS)

    Remer, L. A.; Kaufman, Y. J.; Tanre, D.; Ichoku, C.; Chu, D. A.; Mattoo, S.; Levy, R.; Martins, J. V.; Li, R.-R.; Einaudi, Franco (Technical Monitor)

    2000-01-01

    The MODerate Resolution Imaging Spectroradiometer (MODIS) instrument aboard the Terra spacecraft has been retrieving aerosol parameters since late February 2000. Initial qualitative checking of the products showed very promising results including matching of land and ocean retrievals at coastlines. Using AERONET ground-based radiometers as our primary validation tool, we have established quantitative validation as well. Our results show that for most aerosol types, the MODIS products fall within the pre-launch estimated uncertainties. Surface reflectance and aerosol model assumptions appear to be sufficiently accurate for the optical thickness retrieval. Dust provides a possible exception, which may be due to non-spherical effects. Over ocean the MODIS products include information on particle size, and these parameters are also validated with AERONET retrievals.

  16. High Stability Engine Control (HISTEC): Flight Demonstration Results

    NASA Technical Reports Server (NTRS)

    Delaat, John C.; Southwick, Robert D.; Gallops, George W.; Orme, John S.

    1998-01-01

    Future aircraft turbine engines, both commercial and military, must be able to accommodate expected increased levels of steady-state and dynamic engine-face distortion. The current approach of incorporating sufficient design stall margin to tolerate these increased levels of distortion would significantly reduce performance. The High Stability Engine Control (HISTEC) program has developed technologies for an advanced, integrated engine control system that uses measurement- based estimates of distortion to enhance engine stability. The resulting distortion tolerant control reduces the required design stall margin, with a corresponding increase in performance and/or decrease in fuel burn. The HISTEC concept was successfully flight demonstrated on the F-15 ACTIVE aircraft during the summer of 1997. The flight demonstration was planned and carried out in two parts, the first to show distortion estimation, and the second to show distortion accommodation. Post-flight analysis shows that the HISTEC technologies are able to successfully estimate and accommodate distortion, transiently setting the stall margin requirement on-line and in real-time. Flight demonstration of the HISTEC technologies has significantly reduced the risk of transitioning the technology to tactical and commercial engines.

  17. Demonstration and Validation of Two Coat High Performance Coating System for Steel Structures in Corrosive Environments

    DTIC Science & Technology

    2016-12-01

    System for Steel Structures in Corrosive Environments Final Report on Project F12-AR06 Co ns tr uc tio n En gi ne er in g R es ea rc h La bo ra...Prevention and Control Program ERDC/CERL TR-16-27 December 2016 Demonstration and Validation of Two-Coat High- Performance Coating System for Steel ...Performance Coating System for Steel Structures in Corrosive Environments” ERDC/CERL TR-16-27 ii Abstract Department of Defense (DoD) installations

  18. Video scrambling for privacy protection in video surveillance: recent results and validation framework

    NASA Astrophysics Data System (ADS)

    Dufaux, Frederic

    2011-06-01

    The issue of privacy in video surveillance has drawn a lot of interest lately. However, thorough performance analysis and validation is still lacking, especially regarding the fulfillment of privacy-related requirements. In this paper, we first review recent Privacy Enabling Technologies (PET). Next, we discuss pertinent evaluation criteria for effective privacy protection. We then put forward a framework to assess the capacity of PET solutions to hide distinguishing facial information and to conceal identity. We conduct comprehensive and rigorous experiments to evaluate the performance of face recognition algorithms applied to images altered by PET. Results show the ineffectiveness of naïve PET such as pixelization and blur. Conversely, they demonstrate the effectiveness of more sophisticated scrambling techniques to foil face recognition.

  19. Foothill Transit Battery Electric Bus Demonstration Results : Second Report

    DOT National Transportation Integrated Search

    2017-06-01

    This report summarizes results of a battery electric bus (BEB) evaluation at Foothill Transit, located in the San Gabriel and Pomona Valley region of Los Angeles County, California. Foothill Transit began a demonstration of three Proterra BEBs in Oct...

  20. Strategic Defense Initiative Demonstration/Validation Program Environmental Assessment. Battle Management/Command and Control, and Communications (BM/C3),

    DTIC Science & Technology

    1987-08-01

    POR A ENVIOMNE. STRATEGIC DEFENSE INITRIEDNU T IATI V EI 1 0193 O RTEI ONE..()SRTGC DEFENSE INITIATV E S RATION V EO ORORNIZATION WASINZGTON DC...facilities where Demonstration/Validation activities are planned.- e Ten areas of environmental consideration are addressed: (1) air quality; (2) . water...air quality, rater quality, and hazardous vaste (63). 2.2 ELCTRONIC SYSTEMS DIVISION The Electronic Systems Division administrative offices are located

  1. Demonstration/Validation of the Snap Sampler

    DTIC Science & Technology

    2011-06-01

    0 10 20 30 40 50 60 Low Flow (mg/L) Sn ap S am pl er (m g/ L) Total Iron 0 5 10 15 20 25 0 5 10 15 20 25 Low Flow (mg/L) Sn ap S am pl er...concentrations of Mg. 0 10 20 30 40 50 60 0 10 20 30 40 50 60 Total Mg (mg/L) Fi lte re d M g (m g/ L) Figure 5 -4. Plot comparing concentra- tions...TECHNOLOGY .................... 5   3.0  DEMONSTRATION DESIGN

  2. Examinee Noneffort and the Validity of Program Assessment Results

    ERIC Educational Resources Information Center

    Wise, Steven L.; DeMars, Christine E.

    2010-01-01

    Educational program assessment studies often use data from low-stakes tests to provide evidence of program quality. The validity of scores from such tests, however, is potentially threatened by examinee noneffort. This study investigated the extent to which one type of noneffort--rapid-guessing behavior--distorted the results from three types of…

  3. Validation Test Results for Orthogonal Probe Eddy Current Thruster Inspection System

    NASA Technical Reports Server (NTRS)

    Wincheski, Russell A.

    2007-01-01

    Recent nondestructive evaluation efforts within NASA have focused on an inspection system for the detection of intergranular cracking originating in the relief radius of Primary Reaction Control System (PCRS) Thrusters. Of particular concern is deep cracking in this area which could lead to combustion leakage in the event of through wall cracking from the relief radius into an acoustic cavity of the combustion chamber. In order to reliably detect such defects while ensuring minimal false positives during inspection, the Orthogonal Probe Eddy Current (OPEC) system has been developed and an extensive validation study performed. This report describes the validation procedure, sample set, and inspection results as well as comparing validation flaws with the response from naturally occuring damage.

  4. Ride qualities criteria validation/pilot performance study: Flight test results

    NASA Technical Reports Server (NTRS)

    Nardi, L. U.; Kawana, H. Y.; Greek, D. C.

    1979-01-01

    Pilot performance during a terrain following flight was studied for ride quality criteria validation. Data from manual and automatic terrain following operations conducted during low level penetrations were analyzed to determine the effect of ride qualities on crew performance. The conditions analyzed included varying levels of turbulence, terrain roughness, and mission duration with a ride smoothing system on and off. Limited validation of the B-1 ride quality criteria and some of the first order interactions between ride qualities and pilot/vehicle performance are highlighted. An earlier B-1 flight simulation program correlated well with the flight test results.

  5. Measuring the statistical validity of summary meta-analysis and meta-regression results for use in clinical practice.

    PubMed

    Willis, Brian H; Riley, Richard D

    2017-09-20

    An important question for clinicians appraising a meta-analysis is: are the findings likely to be valid in their own practice-does the reported effect accurately represent the effect that would occur in their own clinical population? To this end we advance the concept of statistical validity-where the parameter being estimated equals the corresponding parameter for a new independent study. Using a simple ('leave-one-out') cross-validation technique, we demonstrate how we may test meta-analysis estimates for statistical validity using a new validation statistic, Vn, and derive its distribution. We compare this with the usual approach of investigating heterogeneity in meta-analyses and demonstrate the link between statistical validity and homogeneity. Using a simulation study, the properties of Vn and the Q statistic are compared for univariate random effects meta-analysis and a tailored meta-regression model, where information from the setting (included as model covariates) is used to calibrate the summary estimate to the setting of application. Their properties are found to be similar when there are 50 studies or more, but for fewer studies Vn has greater power but a higher type 1 error rate than Q. The power and type 1 error rate of Vn are also shown to depend on the within-study variance, between-study variance, study sample size, and the number of studies in the meta-analysis. Finally, we apply Vn to two published meta-analyses and conclude that it usefully augments standard methods when deciding upon the likely validity of summary meta-analysis estimates in clinical practice. © 2017 The Authors. Statistics in Medicine published by John Wiley & Sons Ltd. © 2017 The Authors. Statistics in Medicine published by John Wiley & Sons Ltd.

  6. Remote Agent Demonstration

    NASA Technical Reports Server (NTRS)

    Dorais, Gregory A.; Kurien, James; Rajan, Kanna

    1999-01-01

    We describe the computer demonstration of the Remote Agent Experiment (RAX). The Remote Agent is a high-level, model-based, autonomous control agent being validated on the NASA Deep Space 1 spacecraft.

  7. Cross-Validation of the Africentrism Scale.

    ERIC Educational Resources Information Center

    Kwate, Naa Oyo A.

    2003-01-01

    Cross-validated the Africentrism Scale, investigating the relationship between Africentrism and demographic variables in a diverse sample of individuals of African descent. Results indicated that the scale demonstrated solid internal consistency and convergent validity. Age and education related to Africentrism, with younger and less educated…

  8. 42 CFR 493.569 - Consequences of a finding of noncompliance as a result of a validation inspection.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... result of a validation inspection. 493.569 Section 493.569 Public Health CENTERS FOR MEDICARE & MEDICAID... validation inspection. (a) Laboratory with a certificate of accreditation. If a validation inspection results... validation inspection results in a finding that a CLIA-exempt laboratory is out of compliance with one or...

  9. 42 CFR 493.569 - Consequences of a finding of noncompliance as a result of a validation inspection.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... result of a validation inspection. 493.569 Section 493.569 Public Health CENTERS FOR MEDICARE & MEDICAID... validation inspection. (a) Laboratory with a certificate of accreditation. If a validation inspection results... validation inspection results in a finding that a CLIA-exempt laboratory is out of compliance with one or...

  10. 42 CFR 493.569 - Consequences of a finding of noncompliance as a result of a validation inspection.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... result of a validation inspection. 493.569 Section 493.569 Public Health CENTERS FOR MEDICARE & MEDICAID... validation inspection. (a) Laboratory with a certificate of accreditation. If a validation inspection results... validation inspection results in a finding that a CLIA-exempt laboratory is out of compliance with one or...

  11. 42 CFR 493.569 - Consequences of a finding of noncompliance as a result of a validation inspection.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... result of a validation inspection. 493.569 Section 493.569 Public Health CENTERS FOR MEDICARE & MEDICAID... validation inspection. (a) Laboratory with a certificate of accreditation. If a validation inspection results... validation inspection results in a finding that a CLIA-exempt laboratory is out of compliance with one or...

  12. 42 CFR 493.569 - Consequences of a finding of noncompliance as a result of a validation inspection.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... result of a validation inspection. 493.569 Section 493.569 Public Health CENTERS FOR MEDICARE & MEDICAID... validation inspection. (a) Laboratory with a certificate of accreditation. If a validation inspection results... validation inspection results in a finding that a CLIA-exempt laboratory is out of compliance with one or...

  13. Measuring the statistical validity of summary meta‐analysis and meta‐regression results for use in clinical practice

    PubMed Central

    Riley, Richard D.

    2017-01-01

    An important question for clinicians appraising a meta‐analysis is: are the findings likely to be valid in their own practice—does the reported effect accurately represent the effect that would occur in their own clinical population? To this end we advance the concept of statistical validity—where the parameter being estimated equals the corresponding parameter for a new independent study. Using a simple (‘leave‐one‐out’) cross‐validation technique, we demonstrate how we may test meta‐analysis estimates for statistical validity using a new validation statistic, Vn, and derive its distribution. We compare this with the usual approach of investigating heterogeneity in meta‐analyses and demonstrate the link between statistical validity and homogeneity. Using a simulation study, the properties of Vn and the Q statistic are compared for univariate random effects meta‐analysis and a tailored meta‐regression model, where information from the setting (included as model covariates) is used to calibrate the summary estimate to the setting of application. Their properties are found to be similar when there are 50 studies or more, but for fewer studies Vn has greater power but a higher type 1 error rate than Q. The power and type 1 error rate of Vn are also shown to depend on the within‐study variance, between‐study variance, study sample size, and the number of studies in the meta‐analysis. Finally, we apply Vn to two published meta‐analyses and conclude that it usefully augments standard methods when deciding upon the likely validity of summary meta‐analysis estimates in clinical practice. © 2017 The Authors. Statistics in Medicine published by John Wiley & Sons Ltd. PMID:28620945

  14. COBRA ATD minefield detection results for the Joint Countermine ACTD Demonstrations

    NASA Astrophysics Data System (ADS)

    Stetson, Suzanne P.; Witherspoon, Ned H.; Holloway, John H., Jr.; Suiter, Harold R.; Crosby, Frank J.; Hilton, Russell J.; McCarley, Karen A.

    2000-08-01

    The Coastal Battlefield Reconnaissance and Analysis)COBRA) system described here was a Marine Corps Advanced Technology Demonstration (ATD) development consisting of an unmanned aerial vehicle (UAV) airborne multispectral video sensor system and ground station which processes the multispectral video data to automatically detect minefields along the flight path. After successful completion of the ATD, the residual COBRA ATD system participated in the Joint Countermine (JCM) Advanced Concept Technology Demonstration (ACTD) Demo I held at Camp Lejeune, North Carolina in conjunction with JTFX97 and Demo II held in Stephenville, Newfoundland in conjunction with MARCOT98. These exercises demonstrated the COBRA ATD system in an operational environment, detecting minefields that included several different mine types in widely varying backgrounds. The COBRA system performed superbly during these demonstrations, detecting mines under water, in the surf zone, on the beach, and inland, and has transitioned to an acquisition program. This paper describes the COBRA operation and performance results for these demonstrations, which represent the first demonstrated capability for remote tactical minefield detection from a UAV. The successful COBRA technologies and techniques demonstrated for tactical UAV minefield detection in the Joint Countermine Advanced Concept Technology Demonstrations have formed the technical foundation for future developments in Marine Corps, Navy, and Army tactical remote airborne mine detection systems.

  15. Zero Emission Bay Area (ZEBA) Fuel Cell Bus Demonstration Results : Fourth Report

    DOT National Transportation Integrated Search

    2015-07-04

    This report presents results of a demonstration of fuel cell electric buses (FCEB) operating in Oakland, California. Alameda-Contra Costa Transit District (AC Transit) leads the Zero Emission Bay Area (ZEBA) demonstration, which includes 12 advanced-...

  16. Zero Emission Bay Area (ZEBA) Fuel Cell Bus Demonstration Results : Fifth Report

    DOT National Transportation Integrated Search

    2016-06-01

    This report presents results of a demonstration of fuel cell electric buses (FCEBs) operating in Oakland, California. Alameda-Contra Costa Transit District (AC Transit) leads the Zero Emission Bay Area (ZEBA) demonstration, which includes 13 advanced...

  17. ExEP yield modeling tool and validation test results

    NASA Astrophysics Data System (ADS)

    Morgan, Rhonda; Turmon, Michael; Delacroix, Christian; Savransky, Dmitry; Garrett, Daniel; Lowrance, Patrick; Liu, Xiang Cate; Nunez, Paul

    2017-09-01

    EXOSIMS is an open-source simulation tool for parametric modeling of the detection yield and characterization of exoplanets. EXOSIMS has been adopted by the Exoplanet Exploration Programs Standards Definition and Evaluation Team (ExSDET) as a common mechanism for comparison of exoplanet mission concept studies. To ensure trustworthiness of the tool, we developed a validation test plan that leverages the Python-language unit-test framework, utilizes integration tests for selected module interactions, and performs end-to-end crossvalidation with other yield tools. This paper presents the test methods and results, with the physics-based tests such as photometry and integration time calculation treated in detail and the functional tests treated summarily. The test case utilized a 4m unobscured telescope with an idealized coronagraph and an exoplanet population from the IPAC radial velocity (RV) exoplanet catalog. The known RV planets were set at quadrature to allow deterministic validation of the calculation of physical parameters, such as working angle, photon counts and integration time. The observing keepout region was tested by generating plots and movies of the targets and the keepout zone over a year. Although the keepout integration test required the interpretation of a user, the test revealed problems in the L2 halo orbit and the parameterization of keepout applied to some solar system bodies, which the development team was able to address. The validation testing of EXOSIMS was performed iteratively with the developers of EXOSIMS and resulted in a more robust, stable, and trustworthy tool that the exoplanet community can use to simulate exoplanet direct-detection missions from probe class, to WFIRST, up to large mission concepts such as HabEx and LUVOIR.

  18. Test and Demonstration Assets of New Mexico

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    None

    This document was developed by the Arrowhead Center of New Mexico State University as part of the National Security Preparedness Project (NSPP), funded by a DOE/NNSA grant. The NSPP has three primary components: business incubation, workforce development, and technology demonstration and validation. The document contains a survey of test and demonstration assets in New Mexico available for external users such as small businesses with security technologies under development. Demonstration and validation of national security technologies created by incubator sources, as well as other sources, are critical phases of technology development. The NSPP will support the utilization of an integrated demonstrationmore » and validation environment.« less

  19. Body-borne IED detection: NATO DAT#10 BELCOAST 09 demonstration results

    NASA Astrophysics Data System (ADS)

    Alexander, Naomi; Gómez, Ignacio; Ortega, Isabel; Fiore, Franco; Coman, Cristian

    2010-04-01

    Belgium leads the tenth initiative in the CNAD Programme of Work for the Defense Against Terrorism (PoW DAT), dealing with Critical Infrastructure Protection (CIP). The BELCOAST 09 event, comprising a series of technology demonstrations, was organized to tackle the need for an event that brings together the operational, armaments and technological communities in the field of CIP. A counter terrorism scenario has been created: Terrorist with body-borne IED approaching the entrance of an installation, and a millimeter-wave imager's ability to detect IEDs has been demonstrated. The results of this scenario-based demonstration are presented in this paper.

  20. Zero Emission Bay Area (ZEBA) Fuel Cell Bus Demonstration Results: Sixth Report

    DOT National Transportation Integrated Search

    2017-09-01

    This report presents results of a demonstration of fuel cell electric buses (FCEBs) operating in Oakland, California. Alameda-Contra Costa Transit District (AC Transit) leads the Zero Emission Bay Area (ZEBA) demonstration that includes 13 advanced-d...

  1. Double Cross-Validation in Multiple Regression: A Method of Estimating the Stability of Results.

    ERIC Educational Resources Information Center

    Rowell, R. Kevin

    In multiple regression analysis, where resulting predictive equation effectiveness is subject to shrinkage, it is especially important to evaluate result replicability. Double cross-validation is an empirical method by which an estimate of invariance or stability can be obtained from research data. A procedure for double cross-validation is…

  2. Validation Results for LEWICE 2.0. [Supplement

    NASA Technical Reports Server (NTRS)

    Wright, William B.; Rutkowski, Adam

    1999-01-01

    Two CD-ROMs contain experimental ice shapes and code prediction used for validation of LEWICE 2.0 (see NASA/CR-1999-208690, CASI ID 19990021235). The data include ice shapes for both experiment and for LEWICE, all of the input and output files for the LEWICE cases, JPG files of all plots generated, an electronic copy of the text of the validation report, and a Microsoft Excel(R) spreadsheet containing all of the quantitative measurements taken. The LEWICE source code and executable are not contained on the discs.

  3. Fission Surface Power Technology Demonstration Unit Test Results

    NASA Technical Reports Server (NTRS)

    Briggs, Maxwell H.; Gibson, Marc A.; Geng, Steven M.; Sanzi, James L.

    2016-01-01

    The Fission Surface Power (FSP) Technology Demonstration Unit (TDU) is a system-level demonstration of fission power technology intended for use on manned missions to Mars. The Baseline FSP systems consists of a 190 kWt UO2 fast-spectrum reactor cooled by a primary pumped liquid metal loop. This liquid metal loop transfers heat to two intermediate liquid metal loops designed to isolate fission products in the primary loop from the balance of plant. The intermediate liquid metal loops transfer heat to four Stirling Power Conversion Units (PCU), each of which produce 12 kWe (48 kW total) and reject waste heat to two pumped water loops, which transfer the waste heat to titanium-water heat pipe radiators. The FSP TDU simulates a single leg of the baseline FSP system using an electrically heater core simulator, a single liquid metal loop, a single PCU, and a pumped water loop which rejects the waste heat to a Facility Cooling System (FCS). When operated at the nominal operating conditions (modified for low liquid metal flow) during TDU testing the PCU produced 8.9 kW of power at an efficiency of 21.7 percent resulting in a net system power of 8.1 kW and a system level efficiency of 17.2 percent. The reduction in PCU power from levels seen during electrically heated testing is the result of insufficient heat transfer from the NaK heater head to the Stirling acceptor, which could not be tested at Sunpower prior to delivery to the NASA Glenn Research Center (GRC). The maximum PCU power of 10.4 kW was achieved at the maximum liquid metal temperature of 875 K, minimum water temperature of 350 K, 1.1 kg/s liquid metal flow, 0.39 kg/s water flow, and 15.0 mm amplitude at an efficiency of 23.3 percent. This resulted in a system net power of 9.7 kW and a system efficiency of 18.7 percent.

  4. Fission Surface Power Technology Demonstration Unit Test Results

    NASA Technical Reports Server (NTRS)

    Briggs, Maxwell H.; Gibson, Marc A.; Geng, Steven; Sanzi, James

    2016-01-01

    The Fission Surface Power (FSP) Technology Demonstration Unit (TDU) is a system-level demonstration of fission power technology intended for use on manned missions to Mars. The Baseline FSP systems consists of a 190 kWt UO2 fast-spectrum reactor cooled by a primary pumped liquid metal loop. This liquid metal loop transfers heat to two intermediate liquid metal loops designed to isolate fission products in the primary loop from the balance of plant. The intermediate liquid metal loops transfer heat to four Stirling Power Conversion Units (PCU), each of which produce 12 kWe (48 kW total) and reject waste heat to two pumped water loops, which transfer the waste heat to titanium-water heat pipe radiators. The FSP TDU simulates a single leg of the baseline FSP system using an electrically heater core simulator, a single liquid metal loop, a single PCU, and a pumped water loop which rejects the waste heat to a Facility Cooling System (FCS). When operated at the nominal operating conditions (modified for low liquid metal flow) during TDU testing the PCU produced 8.9 kW of power at an efficiency of 21.7% resulting in a net system power of 8.1 kW and a system level efficiency of 17.2%. The reduction in PCU power from levels seen during electrically heated testing is the result of insufficient heat transfer from the NaK heater head to the Stirling acceptor, which could not be tested at Sunpower prior to delivery to GRC. The maximum PCU power of 10.4 kW was achieved at the maximum liquid metal temperature of 875 K, minimum water temperature of 350 K, 1.1 kg/s liquid metal flow, 0.39 kg/s water flow, and 15.0 mm amplitude at an efficiency of 23.3%. This resulted in a system net power of 9.7 kW and a system efficiency of 18.7 %.

  5. Validation environment for AIPS/ALS: Implementation and results

    NASA Technical Reports Server (NTRS)

    Segall, Zary; Siewiorek, Daniel; Caplan, Eddie; Chung, Alan; Czeck, Edward; Vrsalovic, Dalibor

    1990-01-01

    The work is presented which was performed in porting the Fault Injection-based Automated Testing (FIAT) and Programming and Instrumentation Environments (PIE) validation tools, to the Advanced Information Processing System (AIPS) in the context of the Ada Language System (ALS) application, as well as an initial fault free validation of the available AIPS system. The PIE components implemented on AIPS provide the monitoring mechanisms required for validation. These mechanisms represent a substantial portion of the FIAT system. Moreover, these are required for the implementation of the FIAT environment on AIPS. Using these components, an initial fault free validation of the AIPS system was performed. The implementation is described of the FIAT/PIE system, configured for fault free validation of the AIPS fault tolerant computer system. The PIE components were modified to support the Ada language. A special purpose AIPS/Ada runtime monitoring and data collection was implemented. A number of initial Ada programs running on the PIE/AIPS system were implemented. The instrumentation of the Ada programs was accomplished automatically inside the PIE programming environment. PIE's on-line graphical views show vividly and accurately the performance characteristics of Ada programs, AIPS kernel and the application's interaction with the AIPS kernel. The data collection mechanisms were written in a high level language, Ada, and provide a high degree of flexibility for implementation under various system conditions.

  6. Validation results of satellite mock-up capturing experiment using nets

    NASA Astrophysics Data System (ADS)

    Medina, Alberto; Cercós, Lorenzo; Stefanescu, Raluca M.; Benvenuto, Riccardo; Pesce, Vincenzo; Marcon, Marco; Lavagna, Michèle; González, Iván; Rodríguez López, Nuria; Wormnes, Kjetil

    2017-05-01

    The PATENDER activity (Net parametric characterization and parabolic flight), funded by the European Space Agency (ESA) via its Clean Space initiative, was aiming to validate a simulation tool for designing nets for capturing space debris. This validation has been performed through a set of different experiments under microgravity conditions where a net was launched capturing and wrapping a satellite mock-up. This paper presents the architecture of the thrown-net dynamics simulator together with the set-up of the deployment experiment and its trajectory reconstruction results on a parabolic flight (Novespace A-310, June 2015). The simulator has been implemented within the Blender framework in order to provide a highly configurable tool, able to reproduce different scenarios for Active Debris Removal missions. The experiment has been performed over thirty parabolas offering around 22 s of zero-g conditions. Flexible meshed fabric structure (the net) ejected from a container and propelled by corner masses (the bullets) arranged around its circumference have been launched at different initial velocities and launching angles using a pneumatic-based dedicated mechanism (representing the chaser satellite) against a target mock-up (the target satellite). High-speed motion cameras were recording the experiment allowing 3D reconstruction of the net motion. The net knots have been coloured to allow the images post-process using colour segmentation, stereo matching and iterative closest point (ICP) for knots tracking. The final objective of the activity was the validation of the net deployment and wrapping simulator using images recorded during the parabolic flight. The high-resolution images acquired have been post-processed to determine accurately the initial conditions and generate the reference data (position and velocity of all knots of the net along its deployment and wrapping of the target mock-up) for the simulator validation. The simulator has been properly

  7. Pathfinder Technology Demonstrator: GlobalStar Testing and Results

    NASA Technical Reports Server (NTRS)

    Kuroda, Vanessa; Limes, Gregory L.; Han, Shi Lei; Hanson, John Eric; Christa, Scott E.

    2016-01-01

    The communications subsystem of a spacecraft is typically a SWaP (size, weight, and power) intensive subsystem in a SWaP constrained environment such as a CubeSat. Use of a satellite-based communication system, such as GlobalStars duplex GSP-1720 radio is a low SWaP potentially game-changing low-cost communication subsystem solution that was evaluated for feasibility for the NASA Pathfinder Technology Demonstrator (PTD) project. The PTD project is a series of 6U CubeSat missions to flight demonstrate and characterize novel small satellite payloads in low Earth orbit. GlobalStar is a low Earth orbit satellite constellation for satellite phone and low-speed data communications, and the GSP-1720 is their single board duplex radio most commonly used in satellite phones and shipment tracking devices. The PTD project tested the GSP-1720 to characterize its viability for flight using NASA GEVS (General Environmental Verification Standard) vibration and thermal vacuum levels, as well as testing the uplink-downlink connectivity, data throughput, and file transfer capabilities. This presentation will present the results of the environmental and capability testing of the GSP-1720 performed at NASA Ames Research Center, as well as the viability for CubeSat use in LEO.

  8. Validating a dance-specific screening test for balance: preliminary results from multisite testing.

    PubMed

    Batson, Glenna

    2010-09-01

    Few dance-specific screening tools adequately capture balance. The aim of this study was to administer and modify the Star Excursion Balance Test (oSEBT) to examine its utility as a balance screen for dancers. The oSEBT involves standing on one leg while lightly targeting with the opposite foot to the farthest distance along eight spokes of a star-shaped grid. This task simulates dance in the spatial pattern and movement quality of the gesturing limb. The oSEBT was validated for distance on athletes with history of ankle sprain. Thirty-three dancers (age 20.1 +/- 1.4 yrs) participated from two contemporary dance conservatories (UK and US), with or without a history of lower extremity injury. Dancers were verbally instructed (without physical demonstration) to execute the oSEBT and four modifications (mSEBT): timed (speed), timed with cognitive interference (answering questions aloud), and sensory disadvantaging (foam mat). Stepping strategies were tracked and performance strategies video-recorded. Unlike the oSEBT results, distances reached were not significant statistically (p = 0.05) or descriptively (i.e., shorter) for either group. Performance styles varied widely, despite sample homogeneity and instructions to control for strategy. Descriptive analysis of mSEBT showed an increased number of near-falls and decreased timing on the injured limb. Dancers appeared to employ variable strategies to keep balance during this test. Quantitative analysis is warranted to define balance strategies for further validation of SEBT modifications to determine its utility as a balance screening tool.

  9. Validating Facial Aesthetic Surgery Results with the FACE-Q.

    PubMed

    Kappos, Elisabeth A; Temp, Mathias; Schaefer, Dirk J; Haug, Martin; Kalbermatten, Daniel F; Toth, Bryant A

    2017-04-01

    In aesthetic clinical practice, surgical outcome is best measured by patient satisfaction and quality of life. For many years, there has been a lack of validated questionnaires. Recently, the FACE-Q was introduced, and the authors present the largest series of face-lift patients evaluated by the FACE-Q with the longest follow-up to date. Two hundred consecutive patients were identified who underwent high-superficial musculoaponeurotic system face lifts, with or without additional facial rejuvenation procedures, between January of 2005 and January of 2015. Patients were sent eight FACE-Q scales and were asked to answer questions with regard to their satisfaction. Rank analysis of covariance was used to compare different subgroups. The response rate was 38 percent. Combination of face lift with other procedures resulted in higher satisfaction than face lift alone (p < 0.05). Patients who underwent lipofilling as part of their face lift showed higher satisfaction than patients without lipofilling in three subscales (p < 0.05). Facial rejuvenation surgery, combining a high-superficial musculoaponeurotic system face lift with lipofilling and/or other facial rejuvenation procedures, resulted in a high level of patient satisfaction. The authors recommend the implementation of the FACE-Q by physicians involved in aesthetic facial surgery, to validate their clinical outcomes from a patient's perspective.

  10. Electric Ground Support Equipment Advanced Battery Technology Demonstration Project at the Ontario Airport

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Tyler Gray; Jeremy Diez; Jeffrey Wishart

    2013-07-01

    The intent of the electric Ground Support Equipment (eGSE) demonstration is to evaluate the day-to-day vehicle performance of electric baggage tractors using two advanced battery technologies to demonstrate possible replacements for the flooded lead-acid (FLA) batteries utilized throughout the industry. These advanced battery technologies have the potential to resolve barriers to the widespread adoption of eGSE deployment. Validation testing had not previously been performed within fleet operations to determine if the performance of current advanced batteries is sufficient to withstand the duty cycle of electric baggage tractors. This report summarizes the work performed and data accumulated during this demonstration inmore » an effort to validate the capabilities of advanced battery technologies. This report summarizes the work performed and data accumulated during this demonstration in an effort to validate the capabilities of advanced battery technologies. The demonstration project also grew the relationship with Southwest Airlines (SWA), our demonstration partner at Ontario International Airport (ONT), located in Ontario, California. The results of this study have encouraged a proposal for a future demonstration project with SWA.« less

  11. Wide-field airborne laser diode array illuminator: demonstration results

    NASA Astrophysics Data System (ADS)

    Suiter, H. R.; Holloway, J. H., Jr.; Tinsley, K. R.; Pham, C. N.; Kloess, E. C., III; Witherspoon, N. H.; Stetson, S.; Crosby, F.; Nevis, A.; McCarley, K. A.; Seales, T. C.

    2005-06-01

    The Airborne Littoral Reconnaissance Technology (ALRT) program has successfully demonstrated the Wide-Field Airborne Laser Diode Array Illuminator (ALDAI-W). This illuminator is designed to illuminate a large area from the air with limited power, weight, and volume. A detection system, of which the ALDAI-W is a central portion, is capable of detecting surface-laid minefields in absolute darkness, extending the allowed mission times to night operations. This will be an overview report, giving processing results and suggested paths for additional development.

  12. The status and initial results of the Majorana demonstrator experiment

    NASA Astrophysics Data System (ADS)

    Guiseppe, V. E.; Abgrall, N.; Alvis, S. I.; Arnquist, I. J.; Avignone, F. T.; Barabash, A. S.; Barton, C. J.; Bertrand, F. E.; Bode, T.; Bradley, A. W.; Brudanin, V.; Busch, M.; Buuck, M.; Caldwell, T. S.; Chan, Y.-D.; Christofferson, C. D.; Chu, P.-H.; Cuesta, C.; Detwiler, J. A.; Dunagan, C.; Efremenko, Yu.; Ejiri, H.; Elliott, S. R.; Gilliss, T.; Giovanetti, G. K.; Green, M. P.; Gruszko, J.; Guinn, I. S.; Haufe, C. R.; Hehn, L.; Henning, R.; Hoppe, E. W.; Howe, M. A.; Keeter, K. J.; Kidd, M. F.; Konovalov, S. I.; Kouzes, R. T.; Lopez, A. M.; Martin, R. D.; Massarczyk, R.; Meijer, S. J.; Mertens, S.; Myslik, J.; O'Shaughnessy, C.; Othman, G.; Poon, A. W. P.; Radford, D. C.; Rager, J.; Reine, A. L.; Rielage, K.; Robertson, R. G. H.; Rouf, N. W.; Shanks, B.; Shirchenko, M.; Suriano, A. M.; Tedeschi, D.; Trimble, J. E.; Varner, R. L.; Vasilyev, S.; Vetter, K.; Vorren, K.; White, B. R.; Wilkerson, J. F.; Wiseman, C.; Xu, W.; Yakushev, E.; Yu, C.-H.; Yumatov, V.; Zhitnikov, I.; Zhu, B. X.

    2017-10-01

    Neutrinoless double-beta decay searches play a major role in determining the nature of neutrinos, the existence of a lepton violating process, and the effective Majorana neutrino mass. The Majorana Collaboration assembled an array of high purity Ge detectors to search for neutrinoless double-beta decay in 76Ge. The Majorana Demonstrator is comprised of 44.1 kg (29.7 kg enriched in 76Ge) of Ge detectors divided between two modules contained in a low-background shield at the Sanford Underground Research Facility in Lead, South Dakota, USA. The initial goals of the Demonstrator are to establish the required background and scalability of a Ge-based next-generation ton-scale experiment. Following a commissioning run that started in 2015, the first detector module started low-background data production in early 2016. The second detector module was added in August 2016 to begin operation of the entire array. We discuss results of the initial physics runs, as well as the status and physics reach of the full Majorana Demonstrator experiment.

  13. Validation of spatial variability in downscaling results from the VALUE perfect predictor experiment

    NASA Astrophysics Data System (ADS)

    Widmann, Martin; Bedia, Joaquin; Gutiérrez, Jose Manuel; Maraun, Douglas; Huth, Radan; Fischer, Andreas; Keller, Denise; Hertig, Elke; Vrac, Mathieu; Wibig, Joanna; Pagé, Christian; Cardoso, Rita M.; Soares, Pedro MM; Bosshard, Thomas; Casado, Maria Jesus; Ramos, Petra

    2016-04-01

    VALUE is an open European network to validate and compare downscaling methods for climate change research. Within VALUE a systematic validation framework to enable the assessment and comparison of both dynamical and statistical downscaling methods has been developed. In the first validation experiment the downscaling methods are validated in a setup with perfect predictors taken from the ERA-interim reanalysis for the period 1997 - 2008. This allows to investigate the isolated skill of downscaling methods without further error contributions from the large-scale predictors. One aspect of the validation is the representation of spatial variability. As part of the VALUE validation we have compared various properties of the spatial variability of downscaled daily temperature and precipitation with the corresponding properties in observations. We have used two test validation datasets, one European-wide set of 86 stations, and one higher-density network of 50 stations in Germany. Here we present results based on three approaches, namely the analysis of i.) correlation matrices, ii.) pairwise joint threshold exceedances, and iii.) regions of similar variability. We summarise the information contained in correlation matrices by calculating the dependence of the correlations on distance and deriving decorrelation lengths, as well as by determining the independent degrees of freedom. Probabilities for joint threshold exceedances and (where appropriate) non-exceedances are calculated for various user-relevant thresholds related for instance to extreme precipitation or frost and heat days. The dependence of these probabilities on distance is again characterised by calculating typical length scales that separate dependent from independent exceedances. Regionalisation is based on rotated Principal Component Analysis. The results indicate which downscaling methods are preferable if the dependency of variability at different locations is relevant for the user.

  14. The status and initial results of the MAJORANA DEMONSTRATOR

    NASA Astrophysics Data System (ADS)

    Zhu, Xiaoyu; MAJORANA Collaboration

    2017-01-01

    The MAJORANA DEMONSTRATOR is an ultra-low background experiment searching for neutrinoless double-beta decay in 76Ge at the Sanford Underground Research Facility. The search for neutrinoless double-beta decay could determine the Dirac vs Majorana nature of neutrino mass and provide insight to the matter-antimatter asymmetry in the Universe. The DEMONSTRATOR is comprised of 44.8 kg (30 kg enriched in 76Ge) of high purity Ge detectors separated into two modules. Construction and commissioning of both modules completed in Summer 2016 and both modules are now acquiring physics data. In my talk, I will discuss the initial results of the first physics run utilizing both modules focusing primarily on the studies of the background and projections to a ton-scale experiment. This material is based upon work supported by the U.S. Department of Energy, Office of Science, Office of Nuclear Physics, the Particle Astrophysics Program of the National Science Foundation, and the Sanford Underground Research Facility. We acknowledge the support of the U.S. Department of Energy through the LANL/LDRD Program.

  15. The design of a joined wing flight demonstrator aircraft

    NASA Technical Reports Server (NTRS)

    Smith, S. C.; Cliff, S. E.; Kroo, I. M.

    1987-01-01

    A joined-wing flight demonstrator aircraft has been developed at the NASA Ames Research Center in collaboration with ACA Industries. The aircraft is designed to utilize the fuselage, engines, and undercarriage of the existing NASA AD-1 flight demonstrator aircraft. The design objectives, methods, constraints, and the resulting aircraft design, called the JW-1, are presented. A wind-tunnel model of the JW-1 was tested in the NASA Ames 12-foot wind tunnel. The test results indicate that the JW-1 has satisfactory flying qualities for a flight demonstrator aircraft. Good agreement of test results with design predictions confirmed the validity of the design methods used for application to joined-wing configurations.

  16. Validation Results for LEWICE 3.0

    NASA Technical Reports Server (NTRS)

    Wright, William B.

    2005-01-01

    A research project is underway at NASA Glenn to produce computer software that can accurately predict ice growth under any meteorological conditions for any aircraft surface. This report will present results from version 3.0 of this software, which is called LEWICE. This version differs from previous releases in that it incorporates additional thermal analysis capabilities, a pneumatic boot model, interfaces to computational fluid dynamics (CFD) flow solvers and has an empirical model for the supercooled large droplet (SLD) regime. An extensive comparison of the results in a quantifiable manner against the database of ice shapes and collection efficiency that have been generated in the NASA Glenn Icing Research Tunnel (IRT) has also been performed. The complete set of data used for this comparison will eventually be available in a contractor report. This paper will show the differences in collection efficiency between LEWICE 3.0 and experimental data. Due to the large amount of validation data available, a separate report is planned for ice shape comparison. This report will first describe the LEWICE 3.0 model for water collection. A semi-empirical approach was used to incorporate first order physical effects of large droplet phenomena into icing software. Comparisons are then made to every single element two-dimensional case in the water collection database. Each condition was run using the following five assumptions: 1) potential flow, no splashing; 2) potential flow, no splashing with 21 bin drop size distributions and a lift correction (angle of attack adjustment); 3) potential flow, with splashing; 4) Navier-Stokes, no splashing; and 5) Navier-Stokes, with splashing. Quantitative comparisons are shown for impingement limit, maximum water catch, and total collection efficiency. The results show that the predicted results are within the accuracy limits of the experimental data for the majority of cases.

  17. Demonstrations in Solute Transport Using Dyes: Part I. Procedures and Results.

    ERIC Educational Resources Information Center

    Butters, Greg; Bandaranayake, Wije

    1993-01-01

    Presents the general theory to explain chemical movement in soil. Describes classroom demonstrations with visually stimulating results that show the effects of soil structure, soil texture, soil pH, and soluble organic matter on that movement. (MDH)

  18. Zero Emission Bay Area (ZEBA) Fuel Cell Bus Demonstration Results: Fifth Report

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Eudy, Leslie; Post, Matthew; Jeffers, Matthew

    This report presents results of a demonstration of fuel cell electric buses (FCEB) operating in Oakland, California. Alameda-Contra Costa Transit District (AC Transit) leads the Zero Emission Bay Area (ZEBA) demonstration, which includes 13 advanced-design fuel cell buses and two hydrogen fueling stations. The ZEBA partners are collaborating with the U.S. Department of Energy (DOE) and DOE's National Renewable Energy Laboratory (NREL) to evaluate the buses in revenue service. NREL has published four previous reports describing operation of these buses. This report presents new and updated results covering data from January 2015 through December 2015.

  19. Zero Emission Bay Area (ZEBA) Fuel Cell Bus Demonstration Results: Sixth Report

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Eudy, Leslie; Post, Matthew B.; Jeffers, Matthew A.

    This report presents results of a demonstration of fuel cell electric buses (FCEB) operating in Oakland, California. Alameda-Contra Costa Transit District (AC Transit) leads the Zero Emission Bay Area (ZEBA) demonstration, which includes 13 advanced-design fuel cell buses and two hydrogen fueling stations. The ZEBA partners are collaborating with the U.S. Department of Energy (DOE) and DOE's National Renewable Energy Laboratory (NREL) to evaluate the buses in revenue service. NREL has published five previous reports describing operation of these buses. This report presents new and updated results covering data from January 2016 through December 2016.

  20. CosmoQuest:Using Data Validation for More Than Just Data Validation

    NASA Astrophysics Data System (ADS)

    Lehan, C.; Gay, P.

    2016-12-01

    It is often taken for granted that different scientists completing the same task (e.g. mapping geologic features) will get the same results, and data validation is often skipped or under-utilized due to time and funding constraints. Robbins et. al (2014), however, demonstrated that this is a needed step, as large variation can exist even among collaborating team members completing straight-forward tasks like marking craters. Data Validation should be much more than a simple post-project verification of results. The CosmoQuest virtual research facility employs regular data-validation for a variety of benefits, including real-time user feedback, real-time tracking to observe user activity while it's happening, and using pre-solved data to analyze users' progress and to help them retain skills. Some creativity in this area can drastically improve project results. We discuss methods of validating data in citizen science projects and outline the variety of uses for validation, which, when used properly, improves the scientific output of the project and the user experience for the citizens doing the work. More than just a tool for scientists, validation can assist users in both learning and retaining important information and skills, improving the quality and quantity of data gathered. Real-time analysis of user data can give key information in the effectiveness of the project that a broad glance would miss, and properly presenting that analysis is vital. Training users to validate their own data, or the data of others, can significantly improve the accuracy of misinformed or novice users.

  1. DES Y1 Results: Validating Cosmological Parameter Estimation Using Simulated Dark Energy Surveys

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    MacCrann, N.; et al.

    We use mock galaxy survey simulations designed to resemble the Dark Energy Survey Year 1 (DES Y1) data to validate and inform cosmological parameter estimation. When similar analysis tools are applied to both simulations and real survey data, they provide powerful validation tests of the DES Y1 cosmological analyses presented in companion papers. We use two suites of galaxy simulations produced using different methods, which therefore provide independent tests of our cosmological parameter inference. The cosmological analysis we aim to validate is presented in DES Collaboration et al. (2017) and uses angular two-point correlation functions of galaxy number counts and weak lensing shear, as well as their cross-correlation, in multiple redshift bins. While our constraints depend on the specific set of simulated realisations available, for both suites of simulations we find that the input cosmology is consistent with the combined constraints from multiple simulated DES Y1 realizations in themore » $$\\Omega_m-\\sigma_8$$ plane. For one of the suites, we are able to show with high confidence that any biases in the inferred $$S_8=\\sigma_8(\\Omega_m/0.3)^{0.5}$$ and $$\\Omega_m$$ are smaller than the DES Y1 $$1-\\sigma$$ uncertainties. For the other suite, for which we have fewer realizations, we are unable to be this conclusive; we infer a roughly 70% probability that systematic biases in the recovered $$\\Omega_m$$ and $$S_8$$ are sub-dominant to the DES Y1 uncertainty. As cosmological analyses of this kind become increasingly more precise, validation of parameter inference using survey simulations will be essential to demonstrate robustness.« less

  2. Demonstration of automated proximity and docking technologies

    NASA Astrophysics Data System (ADS)

    Anderson, Robert L.; Tsugawa, Roy K.; Bryan, Thomas C.

    An autodock was demonstrated using straightforward techniques and real sensor hardware. A simulation testbed was established and validated. The sensor design was refined with improved optical performance and image processing noise mitigation techniques, and the sensor is ready for production from off-the-shelf components. The autonomous spacecraft architecture is defined. The areas of sensors, docking hardware, propulsion, and avionics are included in the design. The Guidance Navigation and Control architecture and requirements are developed. Modular structures suitable for automated control are used. The spacecraft system manager functions including configuration, resource, and redundancy management are defined. The requirements for autonomous spacecraft executive are defined. High level decisionmaking, mission planning, and mission contingency recovery are a part of this. The next step is to do flight demonstrations. After the presentation the following question was asked. How do you define validation? There are two components to validation definition: software simulation with formal and vigorous validation, and hardware and facility performance validated with respect to software already validated against analytical profile.

  3. Noninvasive assessment of mitral inertness: clinical results with numerical model validation

    NASA Technical Reports Server (NTRS)

    Firstenberg, M. S.; Greenberg, N. L.; Smedira, N. G.; McCarthy, P. M.; Garcia, M. J.; Thomas, J. D.

    2001-01-01

    Inertial forces (Mdv/dt) are a significant component of transmitral flow, but cannot be measured with Doppler echo. We validated a method of estimating Mdv/dt. Ten patients had a dual sensor transmitral (TM) catheter placed during cardiac surgery. Doppler and 2D echo was performed while acquiring LA and LV pressures. Mdv/dt was determined from the Bernoulli equation using Doppler velocities and TM gradients. Results were compared with numerical modeling. TM gradients (range: 1.04-14.24 mmHg) consisted of 74.0 +/- 11.0% inertial forcers (range: 0.6-12.9 mmHg). Multivariate analysis predicted Mdv/dt = -4.171(S/D (RATIO)) + 0.063(LAvolume-max) + 5. Using this equation, a strong relationship was obtained for the clinical dataset (y=0.98x - 0.045, r=0.90) and the results of numerical modeling (y=0.96x - 0.16, r=0.84). TM gradients are mainly inertial and, as validated by modeling, can be estimated with echocardiography.

  4. Foothill Transit Battery Electric Bus Demonstration Results

    DOT National Transportation Integrated Search

    2016-01-01

    In October 2010, Foothill Transit began a demonstration of three Proterra battery electric buses (BEBs) in its service area located in the San Gabriel and Pomona Valley region of Los Angeles County, California. The agency had a goal of evaluating the...

  5. The NASTRAN demonstration program manual (level 16.0)

    NASA Technical Reports Server (NTRS)

    1976-01-01

    The types of problems that can be solved with NASTRAN are presented. The nature of the problem, the underlying theory, the specific geometric and physical input quanties, and the comparison of theoretical and NASTRAN results are discussed. At least one problem for each of the rigid formats and nearly all of the elements or provided. The features of NASTRAN demonstrated by specific problems are described. The results obtained are valid.

  6. Objectifying Content Validity: Conducting a Content Validity Study in Social Work Research.

    ERIC Educational Resources Information Center

    Rubio, Doris McGartland; Berg-Weger, Marla; Tebb, Susan S.; Lee, E. Suzanne; Rauch, Shannon

    2003-01-01

    The purpose of this article is to demonstrate how to conduct a content validity study. Instructions on how to calculate a content validity index, factorial validity index, and an interrater reliability index and guide for interpreting these indices are included. Implications regarding the value of conducting a content validity study for…

  7. DEMONSTRATION OF RADON RESISTANT CONSTRUCTION TECHNIQUES - PHASE II. FINAL REPORT

    EPA Science Inventory

    The report gives results of a demonstration of radon resistant construction techniques. Sub-slab mitigation systems were installed (in accordance with draft standards) in 15 new Florida houses in 1992, and these houses have undergone extensive testing to validate techniques used ...

  8. NASA Ground-Truthing Capabilities Demonstrated

    NASA Technical Reports Server (NTRS)

    Lopez, Isaac; Seibert, Marc A.

    2004-01-01

    NASA Research and Education Network (NREN) ground truthing is a method of verifying the scientific validity of satellite images and clarifying irregularities in the imagery. Ground-truthed imagery can be used to locate geological compositions of interest for a given area. On Mars, astronaut scientists could ground truth satellite imagery from the planet surface and then pinpoint optimum areas to explore. These astronauts would be able to ground truth imagery, get results back, and use the results during extravehicular activity without returning to Earth to process the data from the mission. NASA's first ground-truthing experiment, performed on June 25 in the Utah desert, demonstrated the ability to extend powerful computing resources to remote locations. Designed by Dr. Richard Beck of the Department of Geography at the University of Cincinnati, who is serving as the lead field scientist, and assisted by Dr. Robert Vincent of Bowling Green State University, the demonstration also involved researchers from the NASA Glenn Research Center and the NASA Ames Research Center, who worked with the university field scientists to design, perform, and analyze results of the experiment. As shown real-time Hyperion satellite imagery (data) is sent to a mass storage facility, while scientists at a remote (Utah) site upload ground spectra (data) to a second mass storage facility. The grid pulls data from both mass storage facilities and performs up to 64 simultaneous band ratio conversions on the data. Moments later, the results from the grid are accessed by local scientists and sent directly to the remote science team. The results are used by the remote science team to locate and explore new critical compositions of interest. The process can be repeated as required to continue to validate the data set or to converge on alternate geophysical areas of interest.

  9. Field Demonstration and Validation of TREECS (trademark) and CTS for the Risk Assessment of Contaminants on Department of Defense (DoD) Ranges

    DTIC Science & Technology

    2017-04-01

    unlimited. N/A The objective of this project was to demonstrate and validate the integrated Training Range Environmental Evaluation and Characterization...Defense (DoD) training and testing ranges. Training Range Environmental Evaluation and Characterization System (TREECS™), Environmental Fate Simulator...Defense (DoD) Ranges” ERDC/EL TR-17-5 ii Abstract The Training Range Environmental Evaluation and Characterization Sys- tem (TREECS™) was developed to

  10. Foothill Transit Battery Electric Bus Demonstration Results: Second Report

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Eudy, Leslie; Jeffers, Matthew

    This report summarizes results of a battery electric bus (BEB) evaluation at Foothill Transit, located in the San Gabriel and Pomona Valley region of Los Angeles County, California. Foothill Transit is collaborating with the California Air Resources Board and the U.S. Department of Energy's (DOE's) National Renewable Energy Laboratory to evaluate its fleet of Proterra BEBs in revenue service. The focus of this evaluation is to compare performance of the BEBs to that of conventional technology and to track progress over time toward meeting performance targets. This project has also provided an opportunity for DOE to conduct a detailed evaluationmore » of the BEBs and charging infrastructure. This is the second report summarizing the results of the BEB demonstration at Foothill Transit and it provides data on the buses from August 2015 through December 2016. Data are provided on a selection of compressed natural gas buses as a baseline comparison.« less

  11. Demonstration of early efficacy results of the delayed-release combination of doxylamine-pyridoxine for the treatment of nausea and vomiting of pregnancy.

    PubMed

    Koren, Gideon; Clark, Shannon; Hankins, Gary D V; Caritis, Steve N; Umans, Jason G; Miodovnik, Menachem; Mattison, Donald R; Matok, Ilan

    2016-11-24

    Nausea and vomiting of pregnancy (NVP) affects up to 80% of expecting mothers. In April 2013 the FDA approved the delayed-release combination of doxylamine succinate and pyridoxine hydrochloride (Diclegis®) for NVP, based in part, on the results of a phase III randomized trial demonstrating the efficacy of this drug combination [study drug marketed under the trade name Diclectin® in Canada and Diclegis® in the United States] compared to placebo in pregnant women. Study drug dosing occurred for 14 days, which is substantially longer than what has been performed in similar studies. The objective of this study was to evaluate, through secondary analysis, whether the primary measure of efficacy can be demonstrated after five days of treatment. Women suffering from NVP were randomized to receive Diclegis® (n = 131) or placebo (n = 125) for 14 days at doses ranging from two to four tablets a day, based on a pre-specified titration protocol. The primary efficacy endpoint was the change in the validated Pregnancy-Unique Quantification of Emesis (PUQE) score at baseline versus Day 15 between Diclegis®-treated and placebo-treated women. For the present study, the change in PUQE score between baseline and Day 15 (end of the study) was compared to the changes observed for Days 3, 4, and 5. The use of delayed-release doxylamine succinate and pyridoxine hydrochloride tablets show improved NVP symptom control as compared to placebo on Days 3,4 and 5, with sustained efficacy until the end of the trial. A four day study drug dosing trial with Diclegis® is sufficient to document efficacy, as the results are similar to those achieved after 14 study drug dosing days. The benefit seen at the earlier time validates drug efficacy and minimizes the natural course of improvement. CTR No. NCT006 14445 2007.

  12. Validation results of specifications for motion control interoperability

    NASA Astrophysics Data System (ADS)

    Szabo, Sandor; Proctor, Frederick M.

    1997-01-01

    The National Institute of Standards and Technology (NIST) is participating in the Department of Energy Technologies Enabling Agile Manufacturing (TEAM) program to establish interface standards for machine tool, robot, and coordinate measuring machine controllers. At NIST, the focus is to validate potential application programming interfaces (APIs) that make it possible to exchange machine controller components with a minimal impact on the rest of the system. This validation is taking place in the enhanced machine controller (EMC) consortium and is in cooperation with users and vendors of motion control equipment. An area of interest is motion control, including closed-loop control of individual axes and coordinated path planning. Initial tests of the motion control APIs are complete. The APIs were implemented on two commercial motion control boards that run on two different machine tools. The results for a baseline set of APIs look promising, but several issues were raised. These include resolving differing approaches in how motions are programmed and defining a standard measurement of performance for motion control. This paper starts with a summary of the process used in developing a set of specifications for motion control interoperability. Next, the EMC architecture and its classification of motion control APIs into two classes, Servo Control and Trajectory Planning, are reviewed. Selected APIs are presented to explain the basic functionality and some of the major issues involved in porting the APIs to other motion controllers. The paper concludes with a summary of the main issues and ways to continue the standards process.

  13. Validity and reliability of the NAB Naming Test.

    PubMed

    Sachs, Bonnie C; Rush, Beth K; Pedraza, Otto

    2016-05-01

    Confrontation naming is commonly assessed in neuropsychological practice, but few standardized measures of naming exist and those that do are susceptible to the effects of education and culture. The Neuropsychological Assessment Battery (NAB) Naming Test is a 31-item measure used to assess confrontation naming. Despite adequate psychometric information provided by the test publisher, there has been limited independent validation of the test. In this study, we investigated the convergent and discriminant validity, internal consistency, and alternate forms reliability of the NAB Naming Test in a sample of adults (Form 1: n = 247, Form 2: n = 151) clinically referred for neuropsychological evaluation. Results indicate adequate-to-good internal consistency and alternate forms reliability. We also found strong convergent validity as demonstrated by relationships with other neurocognitive measures. We found preliminary evidence that the NAB Naming Test demonstrates a more pronounced ceiling effect than other commonly used measures of naming. To our knowledge, this represents the largest published independent validation study of the NAB Naming Test in a clinical sample. Our findings suggest that the NAB Naming Test demonstrates adequate validity and reliability and merits consideration in the test arsenal of clinical neuropsychologists.

  14. King County Metro Battery Electric Bus Demonstration: Preliminary Project Results

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    The U.S. Federal Transit Administration (FTA) funds a variety of research projects that support the commercialization of zero-emission bus technology. To evaluate projects funded through these programs, FTA has enlisted the help of the National Renewable Energy Laboratory (NREL) to conduct third-party evaluations of the technologies deployed under the FTA programs. NREL works with the selected agencies to evaluate the performance of the zero-emission buses compared to baseline conventional buses in similar service. The evaluation effort will advance the knowledge base of zero-emission technologies in transit bus applications and provide 'lessons learned' to aid other fleets in incrementally introducing nextmore » generation zero-emission buses into their operations. This report provides preliminary performance evaluation results from a demonstration of three zero-emission battery electric buses at King County Metro in King County, Washington. NREL developed this preliminary results report to quickly disseminate evaluation results to stakeholders. Detailed evaluation results will be published in future reports.« less

  15. Multiple objective optimization in reliability demonstration test

    DOE PAGES

    Lu, Lu; Anderson-Cook, Christine Michaela; Li, Mingyang

    2016-10-01

    Reliability demonstration tests are usually performed in product design or validation processes to demonstrate whether a product meets specified requirements on reliability. For binomial demonstration tests, the zero-failure test has been most commonly used due to its simplicity and use of minimum sample size to achieve an acceptable consumer’s risk level. However, this test can often result in unacceptably high risk for producers as well as a low probability of passing the test even when the product has good reliability. This paper explicitly explores the interrelationship between multiple objectives that are commonly of interest when planning a demonstration test andmore » proposes structured decision-making procedures using a Pareto front approach for selecting an optimal test plan based on simultaneously balancing multiple criteria. Different strategies are suggested for scenarios with different user priorities and graphical tools are developed to help quantify the trade-offs between choices and to facilitate informed decision making. As a result, potential impacts of some subjective user inputs on the final decision are studied to offer insights and useful guidance for general applications.« less

  16. Results from an Independent View on The Validation of Safety-Critical Space Systems

    NASA Astrophysics Data System (ADS)

    Silva, N.; Lopes, R.; Esper, A.; Barbosa, R.

    2013-08-01

    The Independent verification and validation (IV&V) has been a key process for decades, and is considered in several international standards. One of the activities described in the “ESA ISVV Guide” is the independent test verification (stated as Integration/Unit Test Procedures and Test Data Verification). This activity is commonly overlooked since customers do not really see the added value of checking thoroughly the validation team work (could be seen as testing the tester's work). This article presents the consolidated results of a large set of independent test verification activities, including the main difficulties, results obtained and advantages/disadvantages for the industry of these activities. This study will support customers in opting-in or opting-out for this task in future IV&V contracts since we provide concrete results from real case studies in the space embedded systems domain.

  17. Improving quantitative gas chromatography-electron ionization mass spectrometry results using a modified ion source: demonstration for a pharmaceutical application.

    PubMed

    D'Autry, Ward; Wolfs, Kris; Hoogmartens, Jos; Adams, Erwin; Van Schepdael, Ann

    2011-07-01

    Gas chromatography-mass spectrometry is a well established analytical technique. However, mass spectrometers with electron ionization sources may suffer from signal drifts, hereby negatively influencing quantitative performance. To demonstrate this phenomenon for a real application, a static headspace-gas chromatography method in combination with electron ionization-quadrupole mass spectrometry was optimized for the determination of residual dichloromethane in coronary stent coatings. Validating the method, the quantitative performance of an original stainless steel ion source was compared to that of a modified ion source. Ion source modification included the application of a gold coating on the repeller and exit plate. Several validation aspects such as limit of detection, limit of quantification, linearity and precision were evaluated using both ion sources. It was found that, as expected, the stainless steel ion source suffered from signal drift. As a consequence, non-linearity and high RSD values for repeated analyses were obtained. An additional experiment was performed to check whether an internal standard compound would lead to better results. It was found that the signal drift patterns of the analyte and internal standard were different, consequently leading to high RSD values for the response factor. With the modified ion source however, a more stable signal was observed resulting in acceptable linearity and precision. Moreover, it was also found that sensitivity improved compared to the stainless steel ion source. Finally, the optimized method with the modified ion source was applied to determine residual dichloromethane in the coating of coronary stents. The solvent was detected but found to be below the limit of quantification. Copyright © 2011 Elsevier B.V. All rights reserved.

  18. Zero Emission Bay Area (ZEBA) Fuel Cell Bus Demonstration Results. Fourth Report

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Eudy, Leslie; Post, Matthew

    This report presents results of a demonstration of fuel cell electric buses (FCEB) operating in Oakland, California. Alameda-Contra Costa Transit District (AC Transit) leads the Zero Emission Bay Area (ZEBA) demonstration, which includes 12 advanced-design fuel cell buses and two hydrogen fueling stations. The FCEBs in service at AC Transit are 40-foot, low-floor buses built by Van Hool with a hybrid electric propulsion system that includes a US Hybrid fuel cell power system and EnerDel lithium-based energy storage system. The buses began revenue service in May 2010.

  19. Validation of a scenario-based assessment of critical thinking using an externally validated tool.

    PubMed

    Buur, Jennifer L; Schmidt, Peggy; Smylie, Dean; Irizarry, Kris; Crocker, Carlos; Tyler, John; Barr, Margaret

    2012-01-01

    With medical education transitioning from knowledge-based curricula to competency-based curricula, critical thinking skills have emerged as a major competency. While there are validated external instruments for assessing critical thinking, many educators have created their own custom assessments of critical thinking. However, the face validity of these assessments has not been challenged. The purpose of this study was to compare results from a custom assessment of critical thinking with the results from a validated external instrument of critical thinking. Students from the College of Veterinary Medicine at Western University of Health Sciences were administered a custom assessment of critical thinking (ACT) examination and the externally validated instrument, California Critical Thinking Skills Test (CCTST), in the spring of 2011. Total scores and sub-scores from each exam were analyzed for significant correlations using Pearson correlation coefficients. Significant correlations between ACT Blooms 2 and deductive reasoning and total ACT score and deductive reasoning were demonstrated with correlation coefficients of 0.24 and 0.22, respectively. No other statistically significant correlations were found. The lack of significant correlation between the two examinations illustrates the need in medical education to externally validate internal custom assessments. Ultimately, the development and validation of custom assessments of non-knowledge-based competencies will produce higher quality medical professionals.

  20. Validation of the Intrinsic Spirituality Scale (ISS) with Muslims.

    PubMed

    Hodge, David R; Zidan, Tarek; Husain, Altaf

    2015-12-01

    This study validates an existing spirituality measure--the intrinsic spirituality scale (ISS)--for use with Muslims in the United States. A confirmatory factor analysis was conducted with a diverse sample of self-identified Muslims (N = 281). Validity and reliability were assessed along with criterion and concurrent validity. The measurement model fit the data well, normed χ2 = 2.50, CFI = 0.99, RMSEA = 0.07, and SRMR = 0.02. All 6 items that comprise the ISS demonstrated satisfactory levels of validity (λ > .70) and reliability (R2 > .50). The Cronbach's alpha obtained with the present sample was .93. Appropriate correlations with theoretically linked constructs demonstrated criterion and concurrent validity. The results suggest the ISS is a valid measure of spirituality in clinical settings with the rapidly growing Muslim population. The ISS may, for instance, provide an efficient screening tool to identify Muslims that are particularly likely to benefit from spiritually accommodative treatments. (c) 2015 APA, all rights reserved).

  1. 42 CFR 476.85 - Conclusive effect of QIO initial denial determinations and changes as a result of DRG validations.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... determinations and changes as a result of DRG validations. 476.85 Section 476.85 Public Health CENTERS FOR... denial determinations and changes as a result of DRG validations. A QIO initial denial determination or change as a result of DRG validation is final and binding unless, in accordance with the procedures in...

  2. 42 CFR 476.85 - Conclusive effect of QIO initial denial determinations and changes as a result of DRG validations.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... determinations and changes as a result of DRG validations. 476.85 Section 476.85 Public Health CENTERS FOR... denial determinations and changes as a result of DRG validations. A QIO initial denial determination or change as a result of DRG validation is final and binding unless, in accordance with the procedures in...

  3. 42 CFR 476.85 - Conclusive effect of QIO initial denial determinations and changes as a result of DRG validations.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... determinations and changes as a result of DRG validations. 476.85 Section 476.85 Public Health CENTERS FOR... denial determinations and changes as a result of DRG validations. A QIO initial denial determination or change as a result of DRG validation is final and binding unless, in accordance with the procedures in...

  4. Zero Emission Bay Area (ZEBA) Fuel Cell Bus Demonstration Results : Third Report

    DOT National Transportation Integrated Search

    2014-05-01

    This report presents results of a demonstration of 12 fuel cell electric buses (FCEB) operating in Oakland, California. The FCEBs have a fuel cell dominant hybrid electric propulsion system in a series configuration. The bus manufacturerVan Hool...

  5. Zero Emission Bay Area (ZEBA) Fuel Cell Bus Demonstration : Second Results Report

    DOT National Transportation Integrated Search

    2012-07-04

    This report presents results of a demonstration of 12 new fuel cell electric buses (FCEB) operating in Oakland, California. The FCEBs have a fuel cell dominant hybrid electric propulsion system in a series configuration. The bus manufacturerVan Ho...

  6. Validation of electronic medical record-based phenotyping algorithms: results and lessons learned from the eMERGE network.

    PubMed

    Newton, Katherine M; Peissig, Peggy L; Kho, Abel Ngo; Bielinski, Suzette J; Berg, Richard L; Choudhary, Vidhu; Basford, Melissa; Chute, Christopher G; Kullo, Iftikhar J; Li, Rongling; Pacheco, Jennifer A; Rasmussen, Luke V; Spangler, Leslie; Denny, Joshua C

    2013-06-01

    Genetic studies require precise phenotype definitions, but electronic medical record (EMR) phenotype data are recorded inconsistently and in a variety of formats. To present lessons learned about validation of EMR-based phenotypes from the Electronic Medical Records and Genomics (eMERGE) studies. The eMERGE network created and validated 13 EMR-derived phenotype algorithms. Network sites are Group Health, Marshfield Clinic, Mayo Clinic, Northwestern University, and Vanderbilt University. By validating EMR-derived phenotypes we learned that: (1) multisite validation improves phenotype algorithm accuracy; (2) targets for validation should be carefully considered and defined; (3) specifying time frames for review of variables eases validation time and improves accuracy; (4) using repeated measures requires defining the relevant time period and specifying the most meaningful value to be studied; (5) patient movement in and out of the health plan (transience) can result in incomplete or fragmented data; (6) the review scope should be defined carefully; (7) particular care is required in combining EMR and research data; (8) medication data can be assessed using claims, medications dispensed, or medications prescribed; (9) algorithm development and validation work best as an iterative process; and (10) validation by content experts or structured chart review can provide accurate results. Despite the diverse structure of the five EMRs of the eMERGE sites, we developed, validated, and successfully deployed 13 electronic phenotype algorithms. Validation is a worthwhile process that not only measures phenotype performance but also strengthens phenotype algorithm definitions and enhances their inter-institutional sharing.

  7. 42 CFR 476.85 - Conclusive effect of QIO initial denial determinations and changes as a result of DRG validations.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... determinations and changes as a result of DRG validations. 476.85 Section 476.85 Public Health CENTERS FOR... changes as a result of DRG validations. A QIO initial denial determination or change as a result of DRG validation is final and binding unless, in accordance with the procedures in part 473— (a) The initial denial...

  8. Exploring discrepancies between quantitative validation results and the geomorphic plausibility of statistical landslide susceptibility maps

    NASA Astrophysics Data System (ADS)

    Steger, Stefan; Brenning, Alexander; Bell, Rainer; Petschko, Helene; Glade, Thomas

    2016-06-01

    Empirical models are frequently applied to produce landslide susceptibility maps for large areas. Subsequent quantitative validation results are routinely used as the primary criteria to infer the validity and applicability of the final maps or to select one of several models. This study hypothesizes that such direct deductions can be misleading. The main objective was to explore discrepancies between the predictive performance of a landslide susceptibility model and the geomorphic plausibility of subsequent landslide susceptibility maps while a particular emphasis was placed on the influence of incomplete landslide inventories on modelling and validation results. The study was conducted within the Flysch Zone of Lower Austria (1,354 km2) which is known to be highly susceptible to landslides of the slide-type movement. Sixteen susceptibility models were generated by applying two statistical classifiers (logistic regression and generalized additive model) and two machine learning techniques (random forest and support vector machine) separately for two landslide inventories of differing completeness and two predictor sets. The results were validated quantitatively by estimating the area under the receiver operating characteristic curve (AUROC) with single holdout and spatial cross-validation technique. The heuristic evaluation of the geomorphic plausibility of the final results was supported by findings of an exploratory data analysis, an estimation of odds ratios and an evaluation of the spatial structure of the final maps. The results showed that maps generated by different inventories, classifiers and predictors appeared differently while holdout validation revealed similar high predictive performances. Spatial cross-validation proved useful to expose spatially varying inconsistencies of the modelling results while additionally providing evidence for slightly overfitted machine learning-based models. However, the highest predictive performances were obtained for

  9. Validation of an Empathy Scale in Pharmacy and Nursing Students

    PubMed Central

    Chen, Aleda M. H.; Yehle, Karen S.; Plake, Kimberly S.

    2013-01-01

    Objective. To validate an empathy scale to measure empathy in pharmacy and nursing students. Methods. A 15-item instrument comprised of the cognitive and affective empathy domains, was created. Each item was rated using a 7-point Likert scale, ranging from strongly disagree to strongly agree. Concurrent validity was demonstrated with the Jefferson Scale of Empathy – Health Professional Students (JSE-HPS). Results. Reliability analysis of data from 216 students (pharmacy, N=158; nursing, N=58) showed that scores on the empathy scale were positively associated with JSE-HPS scores (p<0.001). Factor analysis confirmed that 14 of the 15 items were significantly associated with their respective domain, but the overall instrument had limited goodness of fit. Conclusions. Results of this study demonstrate the reliability and validity of a new scale for evaluating student empathy. Further testing of the scale at other universities is needed to establish validity. PMID:23788805

  10. A Demonstration of Validity for Certification by the American Board of Anesthesiology.

    ERIC Educational Resources Information Center

    Slogoff, Stephen; And Others

    1994-01-01

    To investigate the validity of anesthesiologist certification, 146 anesthesiology program directors were asked whether they would permit each of their graduating residents to complete 3 increasingly complex anesthetic regimens to the directors themselves and rate residents on specific skills. Director responses generally correspond to…

  11. Challenges in validating model results for first year ice

    NASA Astrophysics Data System (ADS)

    Melsom, Arne; Eastwood, Steinar; Xie, Jiping; Aaboe, Signe; Bertino, Laurent

    2017-04-01

    In order to assess the quality of model results for the distribution of first year ice, a comparison with a product based on observations from satellite-borne instruments has been performed. Such a comparison is not straightforward due to the contrasting algorithms that are used in the model product and the remote sensing product. The implementation of the validation is discussed in light of the differences between this set of products, and validation results are presented. The model product is the daily updated 10-day forecast from the Arctic Monitoring and Forecasting Centre in CMEMS. The forecasts are produced with the assimilative ocean prediction system TOPAZ. Presently, observations of sea ice concentration and sea ice drift are introduced in the assimilation step, but data for sea ice thickness and ice age (or roughness) are not included. The model computes the age of the ice by recording and updating the time passed after ice formation as sea ice grows and deteriorates as it is advected inside the model domain. Ice that is younger than 365 days is classified as first year ice. The fraction of first-year ice is recorded as a tracer in each grid cell. The Ocean and Sea Ice Thematic Assembly Centre in CMEMS redistributes a daily product from the EUMETSAT OSI SAF of gridded sea ice conditions which include "ice type", a representation of the separation of regions between those infested by first year ice, and those infested by multi-year ice. The ice type is parameterized based on data for the gradient ratio GR(19,37) from SSMIS observations, and from the ASCAT backscatter parameter. This product also includes information on ambiguity in the processing of the remote sensing data, and the product's confidence level, which have a strong seasonal dependency.

  12. High-Rate Wireless Airborne Network Demonstration (HiWAND) Flight Test Results

    NASA Technical Reports Server (NTRS)

    Franz, Russell

    2008-01-01

    An increasing number of flight research and airborne science experiments now contain network-ready systems that could benefit from a high-rate bidirectional air-to-ground network link. A prototype system, the High-Rate Wireless Airborne Network Demonstration, was developed from commercial off-the-shelf components while leveraging the existing telemetry infrastructure on the Western Aeronautical Test Range. This approach resulted in a cost-effective, long-range, line-of-sight network link over the S and the L frequency bands using both frequency modulation and shaped-offset quadrature phase-shift keying modulation. This report discusses system configuration and the flight test results.

  13. High-Rate Wireless Airborne Network Demonstration (HiWAND) Flight Test Results

    NASA Technical Reports Server (NTRS)

    Franz, Russell

    2007-01-01

    An increasing number of flight research and airborne science experiments now contain network-ready systems that could benefit from a high-rate bidirectional air-to-ground network link. A prototype system, the High-Rate Wireless Airborne Network Demonstration, was developed from commercial off-the-shelf components while leveraging the existing telemetry infrastructure on the Western Aeronautical Test Range. This approach resulted in a cost-effective, long-range, line-of-sight network link over the S and the L frequency bands using both frequency modulation and shaped-offset quadrature phase-shift keying modulation. This paper discusses system configuration and the flight test results.

  14. AIRS Retrieval Validation During the EAQUATE

    NASA Technical Reports Server (NTRS)

    Zhou, Daniel K.; Smith, William L.; Cuomo, Vincenzo; Taylor, Jonathan P.; Barnet, Christopher D.; DiGirolamo, Paolo; Pappalardo, Gelsomina; Larar, Allen M.; Liu, Xu; Newman, Stuart M.

    2006-01-01

    Atmospheric and surface thermodynamic parameters retrieved with advanced hyperspectral remote sensors of Earth observing satellites are critical for weather prediction and scientific research. The retrieval algorithms and retrieved parameters from satellite sounders must be validated to demonstrate the capability and accuracy of both observation and data processing systems. The European AQUA Thermodynamic Experiment (EAQUATE) was conducted mainly for validation of the Atmospheric InfraRed Sounder (AIRS) on the AQUA satellite, but also for assessment of validation systems of both ground-based and aircraft-based instruments which will be used for other satellite systems such as the Infrared Atmospheric Sounding Interferometer (IASI) on the European MetOp satellite, the Cross-track Infrared Sounder (CrIS) from the NPOESS Preparatory Project and the following NPOESS series of satellites. Detailed inter-comparisons were conducted and presented using different retrieval methodologies: measurements from airborne ultraspectral Fourier transform spectrometers, aircraft in-situ instruments, dedicated dropsondes and radiosondes, and ground based Raman Lidar, as well as from the European Center for Medium range Weather Forecasting (ECMWF) modeled thermal structures. The results of this study not only illustrate the quality of the measurements and retrieval products but also demonstrate the capability of these validation systems which are put in place to validate current and future hyperspectral sounding instruments and their scientific products.

  15. 42 CFR 476.94 - Notice of QIO initial denial determination and changes as a result of a DRG validation.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... changes as a result of a DRG validation. 476.94 Section 476.94 Public Health CENTERS FOR MEDICARE... changes as a result of a DRG validation. (a) Notice of initial denial determination—(1) Parties to be... working days of identification; (vi) For retrospective review, (excluding DRG validation and post...

  16. Complete Statistical Survey Results of 1982 Texas Competency Validation Project.

    ERIC Educational Resources Information Center

    Rogers, Sandra K.; Dahlberg, Maurine F.

    This report documents a project to develop current statewide validated competencies for auto mechanics, diesel mechanics, welding, office occupations, and printing. Section 1 describes the four steps used in the current competency validation project and provides a standardized process for conducting future studies at the local or statewide level.…

  17. Documenting Progress and Demonstrating Results: Evaluating Local Out-of-School Time Programs.

    ERIC Educational Resources Information Center

    Little, Priscilla; DuPree, Sharon; Deich, Sharon

    A collaborative publication between Harvard Family Research Project and The Finance Project, this brief offers guidance in documenting progress and demonstrating results in local out-of-school-time programs. Following introductory remarks providing a rationale for program evaluation, discussing principles of program evaluation, and clarifying key…

  18. 42 CFR 476.94 - Notice of QIO initial denial determination and changes as a result of a DRG validation.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... changes as a result of a DRG validation. 476.94 Section 476.94 Public Health CENTERS FOR MEDICARE... changes as a result of a DRG validation. (a) Notice of initial denial determination—(1) Parties to be... retrospective review, (excluding DRG validation and post procedure review), within 3 working days of the initial...

  19. 42 CFR 476.94 - Notice of QIO initial denial determination and changes as a result of a DRG validation.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... changes as a result of a DRG validation. 476.94 Section 476.94 Public Health CENTERS FOR MEDICARE... changes as a result of a DRG validation. (a) Notice of initial denial determination—(1) Parties to be... retrospective review, (excluding DRG validation and post procedure review), within 3 working days of the initial...

  20. Validating Measures of Real-World Outcome: The Results of the VALERO Expert Survey and RAND Panel

    PubMed Central

    Leifker, Feea R.; Patterson, Thomas L.; Heaton, Robert K.; Harvey, Philip D.

    2011-01-01

    Background: People with schizophrenia demonstrate considerable discrepancy between self-reported functioning and informant reports. It is not clear whether these discrepancies originate from the instruments used or from the perspectives of different informants. The goal of the Validation of Everyday Real-World Outcomes (VALERO) Study is to enhance the measurement of real-world (RW) outcomes in the social, residential, and vocational domains through selection of optimal scales and informants using a multistep process similar to the Measurement and Treatment Research to Improve Cognition in Schizophrenia (MATRICS) initiative. Methods: Forty-eight experts provided their opinion regarding the best scales measuring RW outcomes. Fifty-nine measures were nominated. The investigators selected the 11 scales that were the most highly nominated, had the most published validity data, and best represented the domains of interest. Information was provided to other experts who served as RAND panelists. Panelists rated each measure for its suitability across multiple a priori domains. Discrepant ratings were discussed until consensus was reached. Results: Following the RAND Panel, the 2 scales that scored highest across the various criteria for each of the classes of scales (hybrid, social functioning, and everyday living skills) were selected for use in the first substudy of VALERO. The scales selected were the Quality-of-Life Scale, Specific Levels of Functioning Scale, Social Behavior Schedule, Social Functioning Scale, Independent Living Skills Schedule, and Life Skills Profile. Discussion: The results show that although there are significant limitations with current scales used for the assessment of RW outcome in schizophrenia, a consensus is possible. Further, several existing instruments were rated as useful for measuring social, residential, and vocational outcomes. PMID:19525354

  1. Interactive chemistry management system (ICMS); Field demonstration results at United Illuminating

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Noto, F.A.; Farrell, D.M.; Lombard, E.V.

    1988-01-01

    The authors report on a field demonstration of the interactive chemistry management system (ICMS) performed in the late summer of 1987 at the New Haven Harbor Station of United Illuminating Co. This demonstration was the first installation of the ICMS at an actual plant site. The ICMS is a computer-based system designed to monitor, diagnose, and provide optional automatic control of water and steam chemistry throughout the steam generator cycle. It is one of the diagnostic modules that comprises CE-TOPS (combustion engineering total on-line performance system), which continuously monitors operating conditions and suggests priority actions to increase operation efficiency, extendmore » the performance life of boiler components and reduce maintenance costs. By reducing the number of forced outages through early identification of potentially detrimental conditions, diagnosis of possible causes, and execution of corrective actions, improvements in unit availability and reliability will result.« less

  2. SEXTANT X-Ray Pulsar Navigation Demonstration: Flight System and Test Results

    NASA Technical Reports Server (NTRS)

    Winternitz, Luke; Mitchell, Jason W.; Hassouneh, Munther A.; Valdez, Jennifer E.; Price, Samuel R.; Semper, Sean R.; Yu, Wayne H.; Ray, Paul S.; Wood, Kent S.; Arzoumanian, Zaven; hide

    2016-01-01

    The Station Explorer for X-ray Timing and Navigation Technology (SEXTANT) is a technology demonstration enhancement to the Neutron-star Interior Composition Explorer (NICER) mission. NICER is a NASA Explorer Mission of Opportunity that will be hosted on the International Space Station (ISS). SEXTANT will, for the first time, demonstrate real-time, on-board X-ray Pulsar Navigation (XNAV), a significant milestone in the quest to establish a GPS-like navigation capability available throughout our Solar System and beyond. This paper gives an overview of the SEXTANT system architecture and describes progress prior to environmental testing of the NICER flight instrument. It provides descriptions and development status of the SEXTANT flight software and ground system, as well as detailed description and results from the flight software functional and performance testing within the high-fidelity Goddard Space Flight Center (GSFC) X-ray Navigation Laboratory Testbed (GXLT) software and hardware simulation environment. Hardware-in-the-loop simulation results are presented, using the engineering model of the NICER timing electronics and the GXLT pulsar simulator-the GXLT precisely controls NASA GSFC's unique Modulated X-ray Source to produce X-rays that make the NICER detector electronics appear as if they were aboard the ISS viewing a sequence of millisecond pulsars

  3. SEXTANT X-Ray Pulsar Navigation Demonstration: Flight System and Test Results

    NASA Technical Reports Server (NTRS)

    Winternitz, Luke M. B.; Mitchell, Jason W.; Hassouneh, Munther A.; Valdez, Jennifer E.; Price, Samuel R.; Semper, Sean R.; Yu, Wayne H.; Ray, Paul S.; Wood, Kent S.; Arzoumanian, Zaven; hide

    2016-01-01

    The Station Explorer for X-ray Timing and Navigation Technology (SEXTANT) is a technology demonstration enhancement to the Neutron-star Interior Composition Explorer (NICER) mission. NICER is a NASA Explorer Mission of Opportunity that will be hosted on the International Space Station (ISS). SEXTANT will, for the first time, demonstrate real-time, on-board X-ray Pulsar Navigation (XNAV), a significant milestone in the quest to establish a GPS-like navigation capability available throughout our Solar System and beyond. This paper gives an overview of the SEXTANT system architecture and describes progress prior to environmental testing of the NICER flight instrument. It provides descriptions and development status of the SEXTANT flight software and ground system, as well as detailed description and results from the flight software functional and performance testing within the highfidelity Goddard Space Flight Center (GSFC) X-ray Navigation Laboratory Testbed (GXLT) software and hardware simulation environment. Hardware-in-the-loop simulation results are presented, using the engineering model of the NICER timing electronics and the GXLT pulsar simulator-the GXLT precisely controls NASA GSFC's unique Modulated X-ray Source to produce X-rays that make the NICER detector electronics appear as if they were aboard the ISS viewing a sequence of millisecond pulsars.

  4. RAVAN CubeSat Results: Technologies and Science Demonstrated On Orbit

    NASA Astrophysics Data System (ADS)

    Swartz, W. H.; Lorentz, S. R.; Huang, P. M.; Smith, A. W.; Yu, Y.; Briscoe, J. S.; Reilly, N.; Reilly, S.; Reynolds, E.; Carvo, J.; Wu, D.

    2017-12-01

    Elucidating Earth's energy budget is vital to understanding and predicting climate, particularly the small imbalance between the incident solar irradiance and Earth-leaving fluxes of total and solar-reflected energy. Accurately quantifying the spatial and temporal variation of Earth's outgoing energy from space is a challenge—one potentially rendered more tractable with the advent of multipoint measurements from small satellite or hosted payload constellations. The Radiometer Assessment using Vertically Aligned Nanotubes (RAVAN) 3U CubeSat, launched November 11, 2016, is a pathfinder for a constellation to measure the Earth's energy imbalance. The objective of RAVAN is to establish that compact, broadband radiometers absolutely calibrated to high accuracy can be built and operated in space for low cost. RAVAN demonstrates two key technologies: (1) vertically aligned carbon nanotubes as spectrally flat radiometer absorbers and (2) gallium phase-change cells for on-board calibration and degradation monitoring of RAVAN's radiometer sensors. We show on-orbit results, including calibrated irradiance measurements at both shortwave, solar-reflected wavelengths and in the thermal infrared. These results are compared with both modeled upwelling fluxes and those measured by independent Earth energy instruments in low-Earth orbit. Further, we show the performance of two gallium phase-change cells that are used to monitor the degradation of RAVAN's radiometer sensors. In addition to Earth energy budget technology and science, RAVAN also demonstrates partnering with a commercial vendor for the CubeSat bus, payload integration and test, and mission operations. We conclude with a discussion of how a RAVAN-type constellation could enable a breakthrough in the measurement of Earth's energy budget and lead to superior predictions of future climate.

  5. Methodology for Computational Fluid Dynamic Validation for Medical Use: Application to Intracranial Aneurysm.

    PubMed

    Paliwal, Nikhil; Damiano, Robert J; Varble, Nicole A; Tutino, Vincent M; Dou, Zhongwang; Siddiqui, Adnan H; Meng, Hui

    2017-12-01

    Computational fluid dynamics (CFD) is a promising tool to aid in clinical diagnoses of cardiovascular diseases. However, it uses assumptions that simplify the complexities of the real cardiovascular flow. Due to high-stakes in the clinical setting, it is critical to calculate the effect of these assumptions in the CFD simulation results. However, existing CFD validation approaches do not quantify error in the simulation results due to the CFD solver's modeling assumptions. Instead, they directly compare CFD simulation results against validation data. Thus, to quantify the accuracy of a CFD solver, we developed a validation methodology that calculates the CFD model error (arising from modeling assumptions). Our methodology identifies independent error sources in CFD and validation experiments, and calculates the model error by parsing out other sources of error inherent in simulation and experiments. To demonstrate the method, we simulated the flow field of a patient-specific intracranial aneurysm (IA) in the commercial CFD software star-ccm+. Particle image velocimetry (PIV) provided validation datasets for the flow field on two orthogonal planes. The average model error in the star-ccm+ solver was 5.63 ± 5.49% along the intersecting validation line of the orthogonal planes. Furthermore, we demonstrated that our validation method is superior to existing validation approaches by applying three representative existing validation techniques to our CFD and experimental dataset, and comparing the validation results. Our validation methodology offers a streamlined workflow to extract the "true" accuracy of a CFD solver.

  6. Hydrogen Fuel Cell Electric Vehicle Learning Demonstration | Hydrogen and

    Science.gov Websites

    Fuel Cells | NREL Fuel Cell Electric Vehicle Learning Demonstration Hydrogen Fuel Cell Electric Vehicle Learning Demonstration Initiated in 2004, DOE's Controlled Hydrogen Fleet and Infrastructure Demonstration and Validation Project-later dubbed the Fuel Cell Electric Vehicle (FCEV) Learning Demonstration

  7. Thermal Expert System (TEXSYS): Systems autonomy demonstration project, volume 2. Results

    NASA Technical Reports Server (NTRS)

    Glass, B. J. (Editor)

    1992-01-01

    The Systems Autonomy Demonstration Project (SADP) produced a knowledge-based real-time control system for control and fault detection, isolation, and recovery (FDIR) of a prototype two-phase Space Station Freedom external active thermal control system (EATCS). The Thermal Expert System (TEXSYS) was demonstrated in recent tests to be capable of reliable fault anticipation and detection, as well as ordinary control of the thermal bus. Performance requirements were addressed by adopting a hierarchical symbolic control approach-layering model-based expert system software on a conventional, numerical data acquisition and control system. The model-based reasoning capabilities of TEXSYS were shown to be advantageous over typical rule-based expert systems, particularly for detection of unforeseen faults and sensor failures. Volume 1 gives a project overview and testing highlights. Volume 2 provides detail on the EATCS testbed, test operations, and online test results. Appendix A is a test archive, while Appendix B is a compendium of design and user manuals for the TEXSYS software.

  8. Thermal Expert System (TEXSYS): Systems autonomy demonstration project, volume 2. Results

    NASA Astrophysics Data System (ADS)

    Glass, B. J.

    1992-10-01

    The Systems Autonomy Demonstration Project (SADP) produced a knowledge-based real-time control system for control and fault detection, isolation, and recovery (FDIR) of a prototype two-phase Space Station Freedom external active thermal control system (EATCS). The Thermal Expert System (TEXSYS) was demonstrated in recent tests to be capable of reliable fault anticipation and detection, as well as ordinary control of the thermal bus. Performance requirements were addressed by adopting a hierarchical symbolic control approach-layering model-based expert system software on a conventional, numerical data acquisition and control system. The model-based reasoning capabilities of TEXSYS were shown to be advantageous over typical rule-based expert systems, particularly for detection of unforeseen faults and sensor failures. Volume 1 gives a project overview and testing highlights. Volume 2 provides detail on the EATCS testbed, test operations, and online test results. Appendix A is a test archive, while Appendix B is a compendium of design and user manuals for the TEXSYS software.

  9. Furthering our Understanding of Land Surface Interactions using SVAT modelling: Results from SimSphere's Validation

    NASA Astrophysics Data System (ADS)

    North, Matt; Petropoulos, George; Ireland, Gareth; Rendal, Daisy; Carlson, Toby

    2015-04-01

    demonstrated greatest simulation accuracies within ecologically stable sites, where low inter-annual change in vegetation phenology was exhibited, such as open woodland savannah, shrub land and mulga woodland, whereas poorer simulation accuracies were attained in cropland and grazing pasture sites. This study results present its first comprehensive validation. It is also very timely due to the rapidly expanding global use of the model, both as a standalone tool used for research, education and training in several institutions worldwide, but also for its synergistic applications to Earth Observation data. Currently, several space agencies are evaluating the model 's use synergistically with Earth Observation data in providing spatio-temporal estimates of energy fluxes and / or soil moisture at operational level. Key Words: SimSphere, Validation, FLUXNET, SVAT, Shortwave Incoming Solar Radiation, Net Radiation, Latent Heat, Sensible Heat, Air Temperature

  10. Hybrid Life Support System Technology Demonstrations

    NASA Astrophysics Data System (ADS)

    Morrow, R. C.; Wetzel, J. P.; Richter, R. C.

    2018-02-01

    Demonstration of plant-based hybrid life support technologies in deep space will validate the function of these technologies for long duration missions, such as Mars transit, while providing dietary variety to improve habitability.

  11. External validation of a Cox prognostic model: principles and methods

    PubMed Central

    2013-01-01

    Background A prognostic model should not enter clinical practice unless it has been demonstrated that it performs a useful role. External validation denotes evaluation of model performance in a sample independent of that used to develop the model. Unlike for logistic regression models, external validation of Cox models is sparsely treated in the literature. Successful validation of a model means achieving satisfactory discrimination and calibration (prediction accuracy) in the validation sample. Validating Cox models is not straightforward because event probabilities are estimated relative to an unspecified baseline function. Methods We describe statistical approaches to external validation of a published Cox model according to the level of published information, specifically (1) the prognostic index only, (2) the prognostic index together with Kaplan-Meier curves for risk groups, and (3) the first two plus the baseline survival curve (the estimated survival function at the mean prognostic index across the sample). The most challenging task, requiring level 3 information, is assessing calibration, for which we suggest a method of approximating the baseline survival function. Results We apply the methods to two comparable datasets in primary breast cancer, treating one as derivation and the other as validation sample. Results are presented for discrimination and calibration. We demonstrate plots of survival probabilities that can assist model evaluation. Conclusions Our validation methods are applicable to a wide range of prognostic studies and provide researchers with a toolkit for external validation of a published Cox model. PMID:23496923

  12. The Deaf Acculturation Scale (DAS): Development and Validation of a 58-Item Measure

    PubMed Central

    Maxwell-McCaw, Deborah; Zea, Maria Cecilia

    2011-01-01

    This study involved the development and validation of the Deaf Acculturation Scale (DAS), a new measure of cultural identity for Deaf and hard-of-hearing (hh) populations. Data for this study were collected online and involved a nation-wide sample of 3,070 deaf/hh individuals. Results indicated strong internal reliabilities for all the subscales, and construct validity was established by demonstrating that the DAS could discriminate groups based on parental hearing status, school background, and use of self-labels. Construct validity was further demonstrated through factorial analyses, and findings resulted in a final 58-item measure. Directions for future research are discussed. PMID:21263041

  13. Validity and Reliability of a Systematic Database Search Strategy to Identify Publications Resulting From Pharmacy Residency Research Projects.

    PubMed

    Kwak, Namhee; Swan, Joshua T; Thompson-Moore, Nathaniel; Liebl, Michael G

    2016-08-01

    This study aims to develop a systematic search strategy and test its validity and reliability in terms of identifying projects published in peer-reviewed journals as reported by residency graduates through an online survey. This study was a prospective blind comparison to a reference standard. Pharmacy residency projects conducted at the study institution between 2001 and 2012 were included. A step-wise, systematic procedure containing up to 8 search strategies in PubMed and EMBASE for each project was created using the names of authors and abstract keywords. In order to further maximize sensitivity, complex phrases with multiple variations were truncated to the root word. Validity was assessed by obtaining information on publications from an online survey deployed to residency graduates. The search strategy identified 13 publications (93% sensitivity, 100% specificity, and 99% accuracy). Both methods identified a similar proportion achieving publication (19.7% search strategy vs 21.2% survey, P = 1.00). Reliability of the search strategy was affirmed by the perfect agreement between 2 investigators (k = 1.00). This systematic search strategy demonstrated a high sensitivity, specificity, and accuracy for identifying publications resulting from pharmacy residency projects using information available in residency conference abstracts. © The Author(s) 2015.

  14. Optimization and validation of moving average quality control procedures using bias detection curves and moving average validation charts.

    PubMed

    van Rossum, Huub H; Kemperman, Hans

    2017-02-01

    To date, no practical tools are available to obtain optimal settings for moving average (MA) as a continuous analytical quality control instrument. Also, there is no knowledge of the true bias detection properties of applied MA. We describe the use of bias detection curves for MA optimization and MA validation charts for validation of MA. MA optimization was performed on a data set of previously obtained consecutive assay results. Bias introduction and MA bias detection were simulated for multiple MA procedures (combination of truncation limits, calculation algorithms and control limits) and performed for various biases. Bias detection curves were generated by plotting the median number of test results needed for bias detection against the simulated introduced bias. In MA validation charts the minimum, median, and maximum numbers of assay results required for MA bias detection are shown for various bias. Their use was demonstrated for sodium, potassium, and albumin. Bias detection curves allowed optimization of MA settings by graphical comparison of bias detection properties of multiple MA. The optimal MA was selected based on the bias detection characteristics obtained. MA validation charts were generated for selected optimal MA and provided insight into the range of results required for MA bias detection. Bias detection curves and MA validation charts are useful tools for optimization and validation of MA procedures.

  15. Analysis procedures and subjective flight results of a simulator validation and cue fidelity experiment

    NASA Technical Reports Server (NTRS)

    Carr, Peter C.; Mckissick, Burnell T.

    1988-01-01

    A joint experiment to investigate simulator validation and cue fidelity was conducted by the Dryden Flight Research Facility of NASA Ames Research Center (Ames-Dryden) and NASA Langley Research Center. The primary objective was to validate the use of a closed-loop pilot-vehicle mathematical model as an analytical tool for optimizing the tradeoff between simulator fidelity requirements and simulator cost. The validation process includes comparing model predictions with simulation and flight test results to evaluate various hypotheses for differences in motion and visual cues and information transfer. A group of five pilots flew air-to-air tracking maneuvers in the Langley differential maneuvering simulator and visual motion simulator and in an F-14 aircraft at Ames-Dryden. The simulators used motion and visual cueing devices including a g-seat, a helmet loader, wide field-of-view horizon, and a motion base platform.

  16. Local Validation of Global Estimates of Biosphere Properties: Synthesis of Scaling Methods and Results Across Several Major Biomes

    NASA Technical Reports Server (NTRS)

    Cohen, Warren B.; Wessman, Carol A.; Aber, John D.; VanderCaslte, John R.; Running, Steven W.

    1998-01-01

    To assist in validating future MODIS land cover, LAI, IPAR, and NPP products, this project conducted a series of prototyping exercises that resulted in enhanced understanding of the issues regarding such validation. As a result, we have several papers to appear as a special issue of Remote Sensing of Environment in 1999. Also, we have been successful at obtaining a follow-on grant to pursue actual validation of these products over the next several years. This document consists of a delivery letter, including a listing of published papers.

  17. Ground test for vibration control demonstrator

    NASA Astrophysics Data System (ADS)

    Meyer, C.; Prodigue, J.; Broux, G.; Cantinaud, O.; Poussot-Vassal, C.

    2016-09-01

    In the objective of maximizing comfort in Falcon jets, Dassault Aviation is developing an innovative vibration control technology. Vibrations of the structure are measured at several locations and sent to a dedicated high performance vibration control computer. Control laws are implemented in this computer to analyse the vibrations in real time, and then elaborate orders sent to the existing control surfaces to counteract vibrations. After detailing the technology principles, this paper focuses on the vibration control ground demonstration that was performed by Dassault Aviation in May 2015 on Falcon 7X business jet. The goal of this test was to attenuate vibrations resulting from fixed forced excitation delivered by shakers. The ground test demonstrated the capability to implement an efficient closed-loop vibration control with a significant vibration level reduction and validated the vibration control law design methodology. This successful ground test was a prerequisite before the flight test demonstration that is now being prepared. This study has been partly supported by the JTI CleanSky SFWA-ITD.

  18. Computer simulation of Cerebral Arteriovenous Malformation-validation analysis of hemodynamics parameters.

    PubMed

    Kumar, Y Kiran; Mehta, Shashi Bhushan; Ramachandra, Manjunath

    2017-01-01

    The purpose of this work is to provide some validation methods for evaluating the hemodynamic assessment of Cerebral Arteriovenous Malformation (CAVM). This article emphasizes the importance of validating noninvasive measurements for CAVM patients, which are designed using lumped models for complex vessel structure. The validation of the hemodynamics assessment is based on invasive clinical measurements and cross-validation techniques with the Philips proprietary validated software's Qflow and 2D Perfursion. The modeling results are validated for 30 CAVM patients for 150 vessel locations. Mean flow, diameter, and pressure were compared between modeling results and with clinical/cross validation measurements, using an independent two-tailed Student t test. Exponential regression analysis was used to assess the relationship between blood flow, vessel diameter, and pressure between them. Univariate analysis is used to assess the relationship between vessel diameter, vessel cross-sectional area, AVM volume, AVM pressure, and AVM flow results were performed with linear or exponential regression. Modeling results were compared with clinical measurements from vessel locations of cerebral regions. Also, the model is cross validated with Philips proprietary validated software's Qflow and 2D Perfursion. Our results shows that modeling results and clinical results are nearly matching with a small deviation. In this article, we have validated our modeling results with clinical measurements. The new approach for cross-validation is proposed by demonstrating the accuracy of our results with a validated product in a clinical environment.

  19. Non-Flow-Through Fuel Cell System Test Results and Demonstration on the SCARAB Rover

    NASA Technical Reports Server (NTRS)

    Scheidegger, Brianne, T.; Burke, Kenneth A.; Jakupca, Ian J.

    2012-01-01

    This paper describes the results of the demonstration of a non-flow-through PEM fuel cell as part of a power system on the SCARAB rover. A 16-cell non-flow-through fuel cell stack from Infinity Fuel Cell and Hydrogen, Inc. was incorporated into a power system designed to act as a range extender by providing power to the rover s hotel loads. This work represents the first attempt at a ground demonstration of this new technology aboard a mobile test platform. Development and demonstration were supported by the Office of the Chief Technologist s Space Power Systems Project and the Advanced Exploration System Modular Power Systems Project.

  20. Validity of proposed DSM-5 diagnostic criteria for nicotine use disorder: results from 734 Israeli lifetime smokers

    PubMed Central

    Shmulewitz, D.; Wall, M.M.; Aharonovich, E.; Spivak, B.; Weizman, A.; Frisch, A.; Grant, B. F.; Hasin, D.

    2013-01-01

    Background The fifth edition of the Diagnostic and Statistical Manual of Mental Disorders (DSM-5) proposes aligning nicotine use disorder (NUD) criteria with those for other substances, by including the current DSM fourth edition (DSM-IV) nicotine dependence (ND) criteria, three abuse criteria (neglect roles, hazardous use, interpersonal problems) and craving. Although NUD criteria indicate one latent trait, evidence is lacking on: (1) validity of each criterion; (2) validity of the criteria as a set; (3) comparative validity between DSM-5 NUD and DSM-IV ND criterion sets; and (4) NUD prevalence. Method Nicotine criteria (DSM-IV ND, abuse and craving) and external validators (e.g. smoking soon after awakening, number of cigarettes per day) were assessed with a structured interview in 734 lifetime smokers from an Israeli household sample. Regression analysis evaluated the association between validators and each criterion. Receiver operating characteristic analysis assessed the association of the validators with the DSM-5 NUD set (number of criteria endorsed) and tested whether DSM-5 or DSM-IV provided the most discriminating criterion set. Changes in prevalence were examined. Results Each DSM-5 NUD criterion was significantly associated with the validators, with strength of associations similar across the criteria. As a set, DSM-5 criteria were significantly associated with the validators, were significantly more discriminating than DSM-IV ND criteria, and led to increased prevalence of binary NUD (two or more criteria) over ND. Conclusions All findings address previous concerns about the DSM-IV nicotine diagnosis and its criteria and support the proposed changes for DSM-5 NUD, which should result in improved diagnosis of nicotine disorders. PMID:23312475

  1. Post mitigation impact risk analysis for asteroid deflection demonstration missions

    NASA Astrophysics Data System (ADS)

    Eggl, Siegfried; Hestroffer, Daniel; Thuillot, William; Bancelin, David; Cano, Juan L.; Cichocki, Filippo

    2015-08-01

    Even though mankind believes to have the capabilities to avert potentially disastrous asteroid impacts, only the realization of mitigation demonstration missions can validate this claim. Such a deflection demonstration attempt has to be cost effective, easy to validate, and safe in the sense that harmless asteroids must not be turned into potentially hazardous objects. Uncertainties in an asteroid's orbital and physical parameters as well as those additionally introduced during a mitigation attempt necessitate an in depth analysis of deflection mission designs in order to dispel planetary safety concerns. We present a post mitigation impact risk analysis of a list of potential kinetic impactor based deflection demonstration missions proposed in the framework of the NEOShield project. Our results confirm that mitigation induced uncertainties have a significant influence on the deflection outcome. Those cannot be neglected in post deflection impact risk studies. We show, furthermore, that deflection missions have to be assessed on an individual basis in order to ensure that asteroids are not inadvertently transported closer to the Earth at a later date. Finally, we present viable targets and mission designs for a kinetic impactor test to be launched between the years 2025 and 2032.

  2. 42 CFR 476.94 - Notice of QIO initial denial determination and changes as a result of a DRG validation.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... changes as a result of a DRG validation. 476.94 Section 476.94 Public Health CENTERS FOR MEDICARE... DRG validation. (a) Notice of initial denial determination—(1) Parties to be notified. A QIO must... of identification; (vi) For retrospective review, (excluding DRG validation and post procedure review...

  3. FLASH fly-by-light flight control demonstration results overview

    NASA Astrophysics Data System (ADS)

    Halski, Don J.

    1996-10-01

    The Fly-By-Light Advanced Systems Hardware (FLASH) program developed Fly-By-Light (FBL) and Power-By-Wire (PBW) technologies for military and commercial aircraft. FLASH consists of three tasks. Task 1 developed the fiber optic cable, connectors, testers and installation and maintenance procedures. Task 3 developed advanced smart, rotary thin wing and electro-hydrostatic (EHA) actuators. Task 2, which is the subject of this paper,l focused on integration of fiber optic sensors and data buses with cable plant components from Task 1 and actuators from Task 3 into centralized and distributed flight control systems. Both open loop and piloted hardware-in-the-loop demonstrations were conducted with centralized and distributed flight control architectures incorporating the AS-1773A optical bus, active hand controllers, optical sensors, optimal flight control laws in high speed 32-bit processors, and neural networks for EHA monitoring and fault diagnosis. This paper overviews the systems level testing conducted under the FLASH Flight Control task. Preliminary results are summarized. Companion papers provide additional information.

  4. Non-Flow-Through Fuel Cell System Test Results and Demonstration on the SCARAB Rover

    NASA Technical Reports Server (NTRS)

    Scheidegger, Brianne; Burke, Kenneth; Jakupca, Ian

    2012-01-01

    This presentation describes the results of the demonstration of a non-flow-through PEM fuel cell as part of a power system on the SCARAB rover at the NASA Glenn Research Center. A 16-cell non-flow-through fuel cell stack from Infinity Fuel Cell and Hydrogen, Inc. was incorporated into a power system designed to act as a range extender by providing power to the SCARAB rover s hotel loads. The power system, including the non-flow-through fuel cell technology, successfully demonstrated its goal as a range extender by powering hotel loads on the SCARAB rover, making this demonstration the first to use the non-flow-through fuel cell technology on a mobile platform.

  5. Hermod: optical payload technology demonstrator flying on PROBA-V: overview of the payload development, testing and results after 1 year in orbit exploitation

    NASA Astrophysics Data System (ADS)

    Hernandez, S.; Blasco, J.; Henriksen, V.; Samuelsson, H.; Navasquillo, O.; Grimsgaard, M.; Mellab, K.

    2017-11-01

    and environmental tests before the integration in a very limited time. The telemetry data is currently sent to ground on daily basis. All the channels have survived the launch and no BER has been measured with the exception of channel 2, currently recording a BER of 3.06*10-16, that exhibits from time to time a burst of errors due to synchronizing issues of the initial data frame. It is expected to observe during the operating life of the payload the first errors within the channel 4 which was designed on purpose with reduced power margin. This paper will present the full overview of the HERMOD technology demonstrator including the development, testing, validation activity, integration, commissioning and 1 year in-orbit exploitation results.

  6. [Validation and verfication of microbiology methods].

    PubMed

    Camaró-Sala, María Luisa; Martínez-García, Rosana; Olmos-Martínez, Piedad; Catalá-Cuenca, Vicente; Ocete-Mochón, María Dolores; Gimeno-Cardona, Concepción

    2015-01-01

    Clinical microbiologists should ensure, to the maximum level allowed by the scientific and technical development, the reliability of the results. This implies that, in addition to meeting the technical criteria to ensure their validity, they must be performed with a number of conditions that allows comparable results to be obtained, regardless of the laboratory that performs the test. In this sense, the use of recognized and accepted reference methodsis the most effective tool for these guarantees. The activities related to verification and validation of analytical methods has become very important, as there is continuous development, as well as updating techniques and increasingly complex analytical equipment, and an interest of professionals to ensure quality processes and results. The definitions of validation and verification are described, along with the different types of validation/verification, and the types of methods, and the level of validation necessary depending on the degree of standardization. The situations in which validation/verification is mandatory and/or recommended is discussed, including those particularly related to validation in Microbiology. It stresses the importance of promoting the use of reference strains as controls in Microbiology and the use of standard controls, as well as the importance of participation in External Quality Assessment programs to demonstrate technical competence. The emphasis is on how to calculate some of the parameters required for validation/verification, such as the accuracy and precision. The development of these concepts can be found in the microbiological process SEIMC number 48: «Validation and verification of microbiological methods» www.seimc.org/protocols/microbiology. Copyright © 2013 Elsevier España, S.L.U. y Sociedad Española de Enfermedades Infecciosas y Microbiología Clínica. All rights reserved.

  7. Results From The Salt Disposition Project Next Generation Solvent Demonstration Plan

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Peters, T. B.; Fondeur, F. F.; Taylor-Pashow, K. M.L.

    2014-04-02

    Strip Effluent Hold Tank (SEHT), Decontaminated Salt Solution Hold Tank (DSSHT), Caustic Wash Tank (CWT) and Solvent Hold Tank (SHT) samples were taken throughout the Next Generation Solvent (NGS) Demonstration Plan. These samples were analyzed and the results are reported. SHT: The solvent behaved as expected, with no bulk changes in the composition over time, with the exception of the TOA and TiDG. The TiDG depletion is higher than expected, and consideration must be taken on the required rate of replenishment. Monthly sampling of the SHT is warranted. If possible, additional SHT samples for TiDG analysis (only) would help SRNLmore » refine the TiDG degradation model. CWT: The CWT samples show the expected behavior in terms of bulk chemistry. The 137Cs deposited into the CWT varies somewhat, but generally appears to be lower than during operations with the BOBCalix solvent. While a few minor organic components were noted to be present in the Preliminary sample, at this time these are thought to be artifacts of the sample preparation or may be due to the preceding solvent superwash. DSSHT: The DSSHT samples show the predicted bulk chemistry, although they point towards significant dilution at the front end of the Demonstration. The 137Cs levels in the DSSHT are much lower than during the BOBCalix operations, which is the expected observation. SEHT: The SEHT samples represent the most different output of all four of the outputs from MCU. While the bulk chemistry is as expected, something is causing the pH of the SEHT to be higher than what would be predicted from a pure stream of 0.01 M boric acid. There are several possible different reasons for this, and SRNL is in the process of investigating. Other than the pH issue, the SEHT is as predicted. In summary, the NGS Demonstration Plan samples indicate that the MCU system, with the Blend Solvent, is operating as expected. The only issue of concern regards the pH of the SEHT, and SRNL is in the process of

  8. Mixed group validation: a method to address the limitations of criterion group validation in research on malingering detection.

    PubMed

    Frederick, R I

    2000-01-01

    Mixed group validation (MGV) is offered as an alternative to criterion group validation (CGV) to estimate the true positive and false positive rates of tests and other diagnostic signs. CGV requires perfect confidence about each research participant's status with respect to the presence or absence of pathology. MGV determines diagnostic efficiencies based on group data; knowing an individual's status with respect to pathology is not required. MGV can use relatively weak indicators to validate better diagnostic signs, whereas CGV requires perfect diagnostic signs to avoid error in computing true positive and false positive rates. The process of MGV is explained, and a computer simulation demonstrates the soundness of the procedure. MGV of the Rey 15-Item Memory Test (Rey, 1958) for 723 pre-trial criminal defendants resulted in higher estimates of true positive rates and lower estimates of false positive rates as compared with prior research conducted with CGV. The author demonstrates how MGV addresses all the criticisms Rogers (1997b) outlined for differential prevalence designs in malingering detection research. Copyright 2000 John Wiley & Sons, Ltd.

  9. Results of Fall 2001 Pilot: Methodology for Validation of Course Prerequisites.

    ERIC Educational Resources Information Center

    Serban, Andreea M.; Fleming, Steve

    The purpose of this study was to test a methodology that will help Santa Barbara City College (SBCC), California, to validate the course prerequisites that fall under the category of highest level of scrutiny--data collection and analysis--as defined by the Chancellor's Office. This study gathered data for the validation of prerequisites for three…

  10. Hospital blood bank information systems accurately reflect patient transfusion: results of a validation study.

    PubMed

    McQuilten, Zoe K; Schembri, Nikita; Polizzotto, Mark N; Akers, Christine; Wills, Melissa; Cole-Sinclair, Merrole F; Whitehead, Susan; Wood, Erica M; Phillips, Louise E

    2011-05-01

    Hospital transfusion laboratories collect information regarding blood transfusion and some registries gather clinical outcomes data without transfusion information, providing an opportunity to integrate these two sources to explore effects of transfusion on clinical outcomes. However, the use of laboratory information system (LIS) data for this purpose has not been validated previously. Validation of LIS data against individual patient records was undertaken at two major centers. Data regarding all transfusion episodes were analyzed over seven 24-hour periods. Data regarding 596 units were captured including 399 red blood cell (RBC), 95 platelet (PLT), 72 plasma, and 30 cryoprecipitate units. They were issued to: inpatient 221 (37.1%), intensive care 109 (18.3%), outpatient 95 (15.9%), operating theater 45 (7.6%), emergency department 27 (4.5%), and unrecorded 99 (16.6%). All products recorded by LIS as issued were documented as transfused to intended patients. Median time from issue to transfusion initiation could be calculated for 535 (89.8%) components: RBCs 16 minutes (95% confidence interval [CI], 15-18 min; interquartile range [IQR], 7-30 min), PLTs 20 minutes (95% CI, 15-22 min; IQR, 10-37 min), fresh-frozen plasma 33 minutes (95% CI, 14-83 min; IQR, 11-134 min), and cryoprecipitate 3 minutes (95% CI, -10 to 42 min; IQR, -15 to 116 min). Across a range of blood component types and destinations comparison of LIS data with clinical records demonstrated concordance. The difference between LIS timing data and patient clinical records reflects expected time to transport, check, and prepare transfusion but does not affect the validity of linkage for most research purposes. Linkage of clinical registries with LIS data can therefore provide robust information regarding individual patient transfusion. This enables analysis of joint data sets to determine the impact of transfusion on clinical outcomes. © 2010 American Association of Blood Banks.

  11. Report: Strategic Agricultural Initiative Needs Revisions to Demonstrate Results

    EPA Pesticide Factsheets

    Report #2007-P-00040, September 26, 2007. The SAI program has not demonstrated how it fulfills its unique role of helping growers transition away from Food Quality Protection Act high-risk pesticides.

  12. Validation of alternative methods for toxicity testing.

    PubMed Central

    Bruner, L H; Carr, G J; Curren, R D; Chamberlain, M

    1998-01-01

    Before nonanimal toxicity tests may be officially accepted by regulatory agencies, it is generally agreed that the validity of the new methods must be demonstrated in an independent, scientifically sound validation program. Validation has been defined as the demonstration of the reliability and relevance of a test method for a particular purpose. This paper provides a brief review of the development of the theoretical aspects of the validation process and updates current thinking about objectively testing the performance of an alternative method in a validation study. Validation of alternative methods for eye irritation testing is a specific example illustrating important concepts. Although discussion focuses on the validation of alternative methods intended to replace current in vivo toxicity tests, the procedures can be used to assess the performance of alternative methods intended for other uses. Images Figure 1 PMID:9599695

  13. Construct Validation of the Piers-Harris Children's Self Concept Scale.

    ERIC Educational Resources Information Center

    Franklin, Melvin R., Jr.; And Others

    1981-01-01

    Results indicated that the Piers-Harris Children's Self Concept Scale demonstrates both convergent and discriminant validity in an assessment of a relatively stable and internally consistent construct. (Author/BW)

  14. ETV/ESTCP Demonstration Plan - Demonstration and Verification of a Turbine Power Generation System Utilizing Renewable Fuel: Landfill Gas

    EPA Science Inventory

    This Test and Quality Assurance Plan (TQAP) provides data quality objections for the success factors that were validated during this demonstration include energy production, emissions and emission reductions compared to alternative systems, economics, and operability, including r...

  15. Integrated restructurable flight control system demonstration results

    NASA Technical Reports Server (NTRS)

    Weiss, Jerold L.; Hsu, John Y.

    1987-01-01

    The purpose of this study was to examine the complementary capabilities of several restructurable flight control system (RFCS) concepts through the integration of these technologies into a complete system. Performance issues were addressed through a re-examination of RFCS functional requirements, and through a qualitative analysis of the design issues that, if properly addressed during integration, will lead to the highest possible degree of fault-tolerant performance. Software developed under previous phases of this contract and under NAS1-18004 was modified and integrated into a complete RFCS subroutine for NASA's B-737 simulation. The integration of these modules involved the development of methods for dealing with the mismatch between the outputs of the failure detection module and the input requirements of the automatic control system redesign module. The performance of this demonstration system was examined through extensive simulation trials.

  16. Validity and reliability of the Malay version of sleep apnea quality of life index – preliminary results

    PubMed Central

    2013-01-01

    Background The objective of this study was to determine the validity and reliability of the Malay translated Sleep Apnea Quality of Life Index (SAQLI) in patients with obstructive sleep apnea (OSA). Methods In this cross sectional study, the Malay version of SAQLI was administered to 82 OSA patients seen at the OSA Clinic, Hospital Universiti Sains Malaysia prior to their treatment. Additionally, the patients were asked to complete the Malay version of Medical Outcomes Study Short Form (SF-36). Twenty-three patients completed the Malay version of SAQLI again after 1–2 weeks to assess its reliability. Results Initial factor analysis of the 40-item Malay version of SAQLI resulted in four factors with eigenvalues >1. All items had factor loadings >0.5 but one of the factors was unstable with only two items. However, both items were maintained due to their high communalities and the analysis was repeated with a forced three factor solution. Variance accounted by the three factors was 78.17% with 9–18 items per factor. All items had primary loadings over 0.5 although the loadings were inconsistent with the proposed construct. The Cronbach’s alpha values were very high for all domains, >0.90. The instrument was able to discriminate between patients with mild or moderate and severe OSA. The Malay version of SAQLI correlated positively with the SF-36. The intraclass correlation coefficients for all domains were >0.90. Conclusions In light of these preliminary observations, we concluded that the Malay version of SAQLI has a high degree of internal consistency and concurrent validity albeit demonstrating a slightly different construct than the original version. The responsiveness of the questionnaire to changes in health-related quality of life following OSA treatment is yet to be determined. PMID:23786866

  17. The trigger card system for the MAJORANA DEMONSTRATOR

    NASA Astrophysics Data System (ADS)

    Thompson, William; Anderson, John; Howe, Mark; Meijer, Sam; Wilkerson, John; Majorana Collaboration

    2014-09-01

    The aim of the MAJORANA DEMONSTRATOR is to demonstrate the feasibility of providing low enough background levels to search for neutrinoless double-beta decay (0 νββ) in an array of germanium detectors enriched to 87% in 76Ge. Currently, it is unknown if this decay process occurs; however, observation of such a decay process would show that lepton number is violated, confirm that neutrinos are Majorana particles, and yield information on the absolute mass scale of the neutrino. With current experimental results indicating a half-life greater than 2 x 1025 years for this decay, the minimization of background events is of critical importance. Utilizing time correlation, coincidence testing is able to reject multi-detector events that may otherwise be mistaken for 0 νββ when viewed independently. Here, we present both the hardware and software of the trigger card system, which provides a common clock to all digitizers and the muon veto system, thereby enabling the rejection of background events through coincidence testing. Current experimental results demonstrate the accuracy of the distributed clock to be within two clock pulses (20 ns) across all system components. A test system is used to validate the data acquisition system. The aim of the MAJORANA DEMONSTRATOR is to demonstrate the feasibility of providing low enough background levels to search for neutrinoless double-beta decay (0 νββ) in an array of germanium detectors enriched to 87% in 76Ge. Currently, it is unknown if this decay process occurs; however, observation of such a decay process would show that lepton number is violated, confirm that neutrinos are Majorana particles, and yield information on the absolute mass scale of the neutrino. With current experimental results indicating a half-life greater than 2 x 1025 years for this decay, the minimization of background events is of critical importance. Utilizing time correlation, coincidence testing is able to reject multi-detector events that may

  18. Final test results for the ground operations demonstration unit for liquid hydrogen

    NASA Astrophysics Data System (ADS)

    Notardonato, W. U.; Swanger, A. M.; Fesmire, J. E.; Jumper, K. M.; Johnson, W. L.; Tomsik, T. M.

    2017-12-01

    Described herein is a comprehensive project-a large-scale test of an integrated refrigeration and storage system called the Ground Operations and Demonstration Unit for Liquid Hydrogen (GODU LH2), sponsored by the Advanced Exploration Systems Program and constructed at Kennedy Space Center. A commercial cryogenic refrigerator interfaced with a 125,000 l liquid hydrogen tank and auxiliary systems in a manner that enabled control of the propellant state by extracting heat via a closed loop Brayton cycle refrigerator coupled to a novel internal heat exchanger. Three primary objectives were demonstrating zero-loss storage and transfer, gaseous liquefaction, and propellant densification. Testing was performed at three different liquid hydrogen fill-levels. Data were collected on tank pressure, internal tank temperature profiles, mass flow in and out of the system, and refrigeration system performance. All test objectives were successfully achieved during approximately two years of testing. A summary of the final results is presented in this paper.

  19. Contamination control and assay results for the Majorana Demonstrator ultra clean components

    NASA Astrophysics Data System (ADS)

    Christofferson, C. D.; Abgrall, N.; Alvis, S. I.; Arnquist, I. J.; Avignone, F. T.; Barabash, A. S.; Barton, C. J.; Bertrand, F. E.; Bode, T.; Bradley, A. W.; Brudanin, V.; Busch, M.; Buuck, M.; Caldwell, T. S.; Chan, Y.-D.; Chu, P.-H.; Cuesta, C.; Detwiler, J. A.; Dunagan, C.; Efremenko, Yu.; Ejiri, H.; Elliott, S. R.; Gilliss, T.; Giovanetti, G. K.; Green, M. P.; Gruszko, J.; Guinn, I. S.; Guiseppe, V. E.; Haufe, C. R.; Hehn, L.; Henning, R.; Hoppe, E. W.; Howe, M. A.; Keeter, K. J.; Kidd, M. F.; Konovalov, S. I.; Kouzes, R. T.; Lopez, A. M.; Martin, R. D.; Massarczyk, R.; Meijer, S. J.; Mertens, S.; Myslik, J.; O'Shaughnessy, C.; Othman, G.; Poon, A. W. P.; Radford, D. C.; Rager, J.; Reine, A. L.; Rielage, K.; Robertson, R. G. H.; Rouf, N. W.; Shanks, B.; Shirchenko, M.; Suriano, A. M.; Tedeschi, D.; Trimble, J. E.; Varner, R. L.; Vasilyev, S.; Vetter, K.; Vorren, K.; White, B. R.; Wilkerson, J. F.; Wiseman, C.; Xu, W.; Yakushev, E.; Yu, C.-H.; Yumatov, V.; Zhitnikov, I.; Zhu, B. X.

    2018-01-01

    The Majorana Demonstrator is a neutrinoless double beta decay experiment utilizing enriched Ge-76 detectors in 2 separate modules inside of a common solid shield at the Sanford Underground Research Facility. The Demonstrator has utilized world leading assay sensitivities to develop clean materials and processes for producing ultra-pure copper and plastic components. This experiment is now operating, and initial data provide new insights into the success of cleaning and processing. Post production copper assays after the completion of Module 1 showed an increase in U and Th contamination in finished parts compared to starting bulk material. A revised cleaning method and additional round of surface contamination studies prior to Module 2 construction have provided evidence that more rigorous process control can reduce surface contamination. This article describes the assay results and discuss further studies to take advantage of assay capabilities for the purpose of maintaining ultra clean fabrication and process design.

  20. Non-Nuclear Validation Test Results of a Closed Brayton Cycle Test-Loop

    NASA Astrophysics Data System (ADS)

    Wright, Steven A.

    2007-01-01

    Both NASA and DOE have programs that are investigating advanced power conversion cycles for planetary surface power on the moon or Mars, or for next generation nuclear power plants on earth. Although open Brayton cycles are in use for many applications (combined cycle power plants, aircraft engines), only a few closed Brayton cycles have been tested. Experience with closed Brayton cycles coupled to nuclear reactors is even more limited and current projections of Brayton cycle performance are based on analytic models. This report describes and compares experimental results with model predictions from a series of non-nuclear tests using a small scale closed loop Brayton cycle available at Sandia National Laboratories. A substantial amount of testing has been performed, and the information is being used to help validate models. In this report we summarize the results from three kinds of tests. These tests include: 1) test results that are useful for validating the characteristic flow curves of the turbomachinery for various gases ranging from ideal gases (Ar or Ar/He) to non-ideal gases such as CO2, 2) test results that represent shut down transients and decay heat removal capability of Brayton loops after reactor shut down, and 3) tests that map a range of operating power versus shaft speed curve and turbine inlet temperature that are useful for predicting stable operating conditions during both normal and off-normal operating behavior. These tests reveal significant interactions between the reactor and balance of plant. Specifically these results predict limited speed up behavior of the turbomachinery caused by loss of load, the conditions for stable operation, and for direct cooled reactors, the tests reveal that the coast down behavior during loss of power events can extend for hours provided the ultimate heat sink remains available.

  1. Validation of NOViSE.

    PubMed

    Korzeniowski, Przemyslaw; Brown, Daniel C; Sodergren, Mikael H; Barrow, Alastair; Bello, Fernando

    2017-02-01

    The goal of this study was to establish face, content, and construct validity of NOViSE-the first force-feedback enabled virtual reality (VR) simulator for natural orifice transluminal endoscopic surgery (NOTES). Fourteen surgeons and surgical trainees performed 3 simulated hybrid transgastric cholecystectomies using a flexible endoscope on NOViSE. Four of them were classified as "NOTES experts" who had independently performed 10 or more simulated or human NOTES procedures. Seven participants were classified as "Novices" and 3 as "Gastroenterologists" with no or minimal NOTES experience. A standardized 5-point Likert-type scale questionnaire was administered to assess the face and content validity. NOViSE showed good overall face and content validity. In 14 out of 15 statements pertaining to face validity (graphical appearance, endoscope and tissue behavior, overall realism), ≥50% of responses were "agree" or "strongly agree." In terms of content validity, 85.7% of participants agreed or strongly agreed that NOViSE is a useful training tool for NOTES and 71.4% that they would recommend it to others. Construct validity was established by comparing a number of performance metrics such as task completion times, path lengths, applied forces, and so on. NOViSE demonstrated early signs of construct validity. Experts were faster and used a shorter endoscopic path length than novices in all but one task. The results indicate that NOViSE authentically recreates a transgastric hybrid cholecystectomy and sets promising foundations for the further development of a VR training curriculum for NOTES without compromising patient safety or requiring expensive animal facilities.

  2. Noninvasive assessment of mitral inertness [correction of inertance]: clinical results with numerical model validation.

    PubMed

    Firstenberg, M S; Greenberg, N L; Smedira, N G; McCarthy, P M; Garcia, M J; Thomas, J D

    2001-01-01

    Inertial forces (Mdv/dt) are a significant component of transmitral flow, but cannot be measured with Doppler echo. We validated a method of estimating Mdv/dt. Ten patients had a dual sensor transmitral (TM) catheter placed during cardiac surgery. Doppler and 2D echo was performed while acquiring LA and LV pressures. Mdv/dt was determined from the Bernoulli equation using Doppler velocities and TM gradients. Results were compared with numerical modeling. TM gradients (range: 1.04-14.24 mmHg) consisted of 74.0 +/- 11.0% inertial forcers (range: 0.6-12.9 mmHg). Multivariate analysis predicted Mdv/dt = -4.171(S/D (RATIO)) + 0.063(LAvolume-max) + 5. Using this equation, a strong relationship was obtained for the clinical dataset (y=0.98x - 0.045, r=0.90) and the results of numerical modeling (y=0.96x - 0.16, r=0.84). TM gradients are mainly inertial and, as validated by modeling, can be estimated with echocardiography.

  3. Michigan Oncology Medical Home Demonstration Project: First-Year Results.

    PubMed

    Kuntz, Gordon; Tozer, Jane; Snegosky, Jeff; Fox, John; Neumann, Kurt

    2014-03-01

    The Michigan Oncology Medical Home Demonstration Project (MOMHDP) is an innovative multipractice oncology medical home model, supported by payment reform. Sponsored by Priority Health, Physician Resource Management, and ION Solutions, MOMHDP includes four oncology practices and 29 physicians. Oncology practices used existing technologies, with MOMHDP providing evidence-based treatment guideline selection and compliance tracking, automated physician order entry, a patient portal, symptom management/standardized nurse triage, and advance care planning. To support changes in care and administrative models and to focus on quality, MOMHDP modifies provider payments. The program replaces the average sales price payment methodology with a drug acquisition reimbursement plus a care management fee, calculated to increase total drug reimbursement. Additionally, it reimburses for chemotherapy and treatment planning and advance care planning consultation. There is also a shared savings opportunity. MOMHDP will be enhanced in its second year to include a survivorship program, patient distress screening, imaging guidelines, and standardized patient satisfaction surveys. Priority Health patients receiving chemotherapy for a cancer diagnosis were recruited to the program. Results for this group were compared with a control group of patients from a prior period. In addition to the financial results, the project also accomplished the following: (1) adherence to practice-selected guidelines, (2) institution of advance care planning, (3) effective and standardized symptom management; and (4) payment reform. We have identified a number of critical success factors: strong payer/provider collaboration built on trust through transparent use and cost data; timing of clinical standardization must come from the practices, so they can effectively absorb new approaches; having comprehensive, written program documentation and consistently applied training facilitate practice understanding

  4. Validity and Reliability of the 8-Item Work Limitations Questionnaire.

    PubMed

    Walker, Timothy J; Tullar, Jessica M; Diamond, Pamela M; Kohl, Harold W; Amick, Benjamin C

    2017-12-01

    Purpose To evaluate factorial validity, scale reliability, test-retest reliability, convergent validity, and discriminant validity of the 8-item Work Limitations Questionnaire (WLQ) among employees from a public university system. Methods A secondary analysis using de-identified data from employees who completed an annual Health Assessment between the years 2009-2015 tested research aims. Confirmatory factor analysis (CFA) (n = 10,165) tested the latent structure of the 8-item WLQ. Scale reliability was determined using a CFA-based approach while test-retest reliability was determined using the intraclass correlation coefficient. Convergent/discriminant validity was tested by evaluating relations between the 8-item WLQ with health/performance variables for convergent validity (health-related work performance, number of chronic conditions, and general health) and demographic variables for discriminant validity (gender and institution type). Results A 1-factor model with three correlated residuals demonstrated excellent model fit (CFI = 0.99, TLI = 0.99, RMSEA = 0.03, and SRMR = 0.01). The scale reliability was acceptable (0.69, 95% CI 0.68-0.70) and the test-retest reliability was very good (ICC = 0.78). Low-to-moderate associations were observed between the 8-item WLQ and the health/performance variables while weak associations were observed between the demographic variables. Conclusions The 8-item WLQ demonstrated sufficient reliability and validity among employees from a public university system. Results suggest the 8-item WLQ is a usable alternative for studies when the more comprehensive 25-item WLQ is not available.

  5. Factor complexity of crash occurrence: An empirical demonstration using boosted regression trees.

    PubMed

    Chung, Yi-Shih

    2013-12-01

    Factor complexity is a characteristic of traffic crashes. This paper proposes a novel method, namely boosted regression trees (BRT), to investigate the complex and nonlinear relationships in high-variance traffic crash data. The Taiwanese 2004-2005 single-vehicle motorcycle crash data are used to demonstrate the utility of BRT. Traditional logistic regression and classification and regression tree (CART) models are also used to compare their estimation results and external validities. Both the in-sample cross-validation and out-of-sample validation results show that an increase in tree complexity provides improved, although declining, classification performance, indicating a limited factor complexity of single-vehicle motorcycle crashes. The effects of crucial variables including geographical, time, and sociodemographic factors explain some fatal crashes. Relatively unique fatal crashes are better approximated by interactive terms, especially combinations of behavioral factors. BRT models generally provide improved transferability than conventional logistic regression and CART models. This study also discusses the implications of the results for devising safety policies. Copyright © 2012 Elsevier Ltd. All rights reserved.

  6. How well do adolescents recall use of mobile telephones? Results of a validation study

    PubMed Central

    2009-01-01

    Background In the last decade mobile telephone use has become more widespread among children. Concerns expressed about possible health risks have led to epidemiological studies investigating adverse health outcomes associated with mobile telephone use. Most epidemiological studies have relied on self reported questionnaire responses to determine individual exposure. We sought to validate the accuracy of self reported adolescent mobile telephone use. Methods Participants were recruited from year 7 secondary school students in Melbourne, Australia. Adolescent recall of mobile telephone use was assessed using a self administered questionnaire which asked about number and average duration of calls per week. Validation of self reports was undertaken using Software Modified Phones (SMPs) which logged exposure details such as number and duration of calls. Results A total of 59 adolescents participated (39% boys, 61% girls). Overall a modest but significant rank correlation was found between self and validated number of voice calls (ρ = 0.3, P = 0.04) with a sensitivity of 57% and specificity of 66%. Agreement between SMP measured and self reported duration of calls was poorer (ρ = 0.1, P = 0.37). Participants whose parents belonged to the 4th socioeconomic stratum recalled mobile phone use better than others (ρ = 0.6, P = 0.01). Conclusion Adolescent recall of mobile telephone use was only modestly accurate. Caution is warranted in interpreting results of epidemiological studies investigating health effects of mobile phone use in this age group. PMID:19523193

  7. Autonomous Airborne Refueling Demonstration, Phase I Flight-Test Results

    NASA Technical Reports Server (NTRS)

    Dibley, Ryan P.; Allen, Michael J.; Nabaa, Nassib

    2007-01-01

    The first phase of the Autonomous Airborne Refueling Demonstration (AARD) project was completed on August 30, 2006. The goal of this 15-month effort was to develop and flight-test a system to demonstrate an autonomous refueling engagement using the Navy style hose-and-drogue air-to-air refueling method. The prime contractor for this Defense Advanced Research Projects Agency (DARPA) sponsored program was Sierra Nevada Corporation (SNC), Sparks, Nevada. The responsible flight-test organization was the NASA Dryden Flight Research Center (DFRC), Edwards, California, which also provided the F/A-18 receiver airplane (McDonnell Douglas, now The Boeing Company, Chicago, Illinois). The B-707-300 tanker airplane (The Boeing Company) was contracted through Omega Aerial Refueling Services, Inc., Alexandria, Virginia, and the optical tracking system was contracted through OCTEC Ltd., Bracknell, Berkshire, United Kingdom. Nine research flights were flown, testing the functionality and performance of the system in a stepwise manner, culminating in the plug attempts on the final flight. Relative position keeping was found to be very stable and accurate. The receiver aircraft was capable of following the tanker aircraft through turns while maintaining its relative position. During the last flight, six capture attempts were made, two of which were successful. The four misses demonstrated excellent characteristics, the receiver retreating from the drogue in a controlled, safe, and predictable manner that precluded contact between the drogue and the receiver aircraft. The position of the receiver aircraft when engaged and in position for refueling was found to be 5.5 to 8.5 ft low of the ideal position. The controller inputs to the F/A-18 were found to be extremely small

  8. Fiber-optic sensor demonstrator (FSD) preliminary test results on PROBA-2

    NASA Astrophysics Data System (ADS)

    Kruzelecky, Roman V.; Zou, Jing; Haddad, Emile; Jamroz, Wes; Ricci, Francesco; Edwards, Eric; McKenzie, Iain; Vuilleumier, Pierrik

    2017-11-01

    Fiber Sensor Demonstrator (FSD) developed by MPB Communications (MPBC) is the first demonstration of a full fiber-optic sensor network in the space environment on a satellite. FSD has been launched on ESA's Proba-2 satellite in November 2009. FSD contains twelve temperature sensors to measure the temperature at different locations in the satellite, and one High-Temperature sensor to measure the transient high temperature in the thruster, as well as one pressure sensor to measure the xenon tank pressure. First set of on-orbit test data were obtained in January 2010. The FSD unit successfully established the communication with Proba-2. The temperature of FSD unit was also acquired through a AD590 sensor inside the unit. The measurements of all the optical fiber sensor lines will be evaluated after the testing results obtained. The FSD contains twelve specially-packaged FBG temperature sensors to measure the temperature at different locations in the propulsion system and the spacecraft over the range of -60°C to +120°C. A high-temperature sensor is provided to measure the transient temperature response of the thruster to beyond 350°C. There is also an innovative P/T sensor that provides both temperature and pressure measurements of the Xe propellant tank. The preliminary data of on-orbit functional testing and temperature measurements are provided mainly in Section 6.

  9. Network Security Validation Using Game Theory

    NASA Astrophysics Data System (ADS)

    Papadopoulou, Vicky; Gregoriades, Andreas

    Non-functional requirements (NFR) such as network security recently gained widespread attention in distributed information systems. Despite their importance however, there is no systematic approach to validate these requirements given the complexity and uncertainty characterizing modern networks. Traditionally, network security requirements specification has been the results of a reactive process. This however, limited the immunity property of the distributed systems that depended on these networks. Security requirements specification need a proactive approach. Networks' infrastructure is constantly under attack by hackers and malicious software that aim to break into computers. To combat these threats, network designers need sophisticated security validation techniques that will guarantee the minimum level of security for their future networks. This paper presents a game-theoretic approach to security requirements validation. An introduction to game theory is presented along with an example that demonstrates the application of the approach.

  10. Cloud computing and validation of expandable in silico livers

    PubMed Central

    2010-01-01

    Background In Silico Livers (ISLs) are works in progress. They are used to challenge multilevel, multi-attribute, mechanistic hypotheses about the hepatic disposition of xenobiotics coupled with hepatic responses. To enhance ISL-to-liver mappings, we added discrete time metabolism, biliary elimination, and bolus dosing features to a previously validated ISL and initiated re-validated experiments that required scaling experiments to use more simulated lobules than previously, more than could be achieved using the local cluster technology. Rather than dramatically increasing the size of our local cluster we undertook the re-validation experiments using the Amazon EC2 cloud platform. So doing required demonstrating the efficacy of scaling a simulation to use more cluster nodes and assessing the scientific equivalence of local cluster validation experiments with those executed using the cloud platform. Results The local cluster technology was duplicated in the Amazon EC2 cloud platform. Synthetic modeling protocols were followed to identify a successful parameterization. Experiment sample sizes (number of simulated lobules) on both platforms were 49, 70, 84, and 152 (cloud only). Experimental indistinguishability was demonstrated for ISL outflow profiles of diltiazem using both platforms for experiments consisting of 84 or more samples. The process was analogous to demonstration of results equivalency from two different wet-labs. Conclusions The results provide additional evidence that disposition simulations using ISLs can cover the behavior space of liver experiments in distinct experimental contexts (there is in silico-to-wet-lab phenotype similarity). The scientific value of experimenting with multiscale biomedical models has been limited to research groups with access to computer clusters. The availability of cloud technology coupled with the evidence of scientific equivalency has lowered the barrier and will greatly facilitate model sharing as well as provide

  11. 49 CFR 40.160 - What does the MRO do when a valid test result cannot be produced and a negative result is required?

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... 49 Transportation 1 2013-10-01 2013-10-01 false What does the MRO do when a valid test result cannot be produced and a negative result is required? 40.160 Section 40.160 Transportation Office of the Secretary of Transportation PROCEDURES FOR TRANSPORTATION WORKPLACE DRUG AND ALCOHOL TESTING PROGRAMS Medical Review Officers and the Verification...

  12. JaCVAM-organized international validation study of the in vivo rodent alkaline comet assay for detection of genotoxic carcinogens: II. Summary of definitive validation study results.

    PubMed

    Uno, Yoshifumi; Kojima, Hajime; Omori, Takashi; Corvi, Raffaella; Honma, Masamistu; Schechtman, Leonard M; Tice, Raymond R; Beevers, Carol; De Boeck, Marlies; Burlinson, Brian; Hobbs, Cheryl A; Kitamoto, Sachiko; Kraynak, Andrew R; McNamee, James; Nakagawa, Yuzuki; Pant, Kamala; Plappert-Helbig, Ulla; Priestley, Catherine; Takasawa, Hironao; Wada, Kunio; Wirnitzer, Uta; Asano, Norihide; Escobar, Patricia A; Lovell, David; Morita, Takeshi; Nakajima, Madoka; Ohno, Yasuo; Hayashi, Makoto

    2015-07-01

    The in vivo rodent alkaline comet assay (comet assay) is used internationally to investigate the in vivo genotoxic potential of test chemicals. This assay, however, has not previously been formally validated. The Japanese Center for the Validation of Alternative Methods (JaCVAM), with the cooperation of the U.S. NTP Interagency Center for the Evaluation of Alternative Toxicological Methods (NICEATM)/the Interagency Coordinating Committee on the Validation of Alternative Methods (ICCVAM), the European Centre for the Validation of Alternative Methods (ECVAM), and the Japanese Environmental Mutagen Society/Mammalian Mutagenesis Study Group (JEMS/MMS), organized an international validation study to evaluate the reliability and relevance of the assay for identifying genotoxic carcinogens, using liver and stomach as target organs. The ultimate goal of this exercise was to establish an Organisation for Economic Co-operation and Development (OECD) test guideline. The study protocol was optimized in the pre-validation studies, and then the definitive (4th phase) validation study was conducted in two steps. In the 1st step, assay reproducibility was confirmed among laboratories using four coded reference chemicals and the positive control ethyl methanesulfonate. In the 2nd step, the predictive capability was investigated using 40 coded chemicals with known genotoxic and carcinogenic activity (i.e., genotoxic carcinogens, genotoxic non-carcinogens, non-genotoxic carcinogens, and non-genotoxic non-carcinogens). Based on the results obtained, the in vivo comet assay is concluded to be highly capable of identifying genotoxic chemicals and therefore can serve as a reliable predictor of rodent carcinogenicity. Copyright © 2015 Elsevier B.V. All rights reserved.

  13. Autonomous Airborne Refueling Demonstration: Phase I Flight-Test Results

    NASA Technical Reports Server (NTRS)

    Dibley, Ryan P.; Allen, Michael J.; Nabaa, Nassib

    2007-01-01

    The first phase of the Autonomous Airborne Refueling Demonstration (AARD) project was completed on August 30, 2006. The goal of this 15-month effort was to develop and flight-test a system to demonstrate an autonomous refueling engagement using the Navy style hose-and-drogue air-to-air refueling method. The prime contractor for this Defense Advanced Research Projects Agency (DARPA) sponsored program was Sierra Nevada Corporation (SNC), Sparks, Nevada. The responsible flight-test organization was the National Aeronautics and Space Administration (NASA) Dryden Flight Research Center (DFRC), Edwards, California, which also provided the F/A-18 receiver airplane (McDonnell Douglas, now The Boeing Company, Chicago, Illinois). The B-707-300 tanker airplane (The Boeing Company) was contracted through Omega Aerial Refueling Services, Inc., Alexandria, Virginia, and the optical tracking system was contracted through OCTEC Ltd., Bracknell, Berkshire, United Kingdom. Nine research flights were flown, testing the functionality and performance of the system in a stepwise manner, culminating in the plug attempts on the final flight. Relative position keeping was found to be very stable and accurate. The receiver aircraft was capable of following the tanker aircraft through turns while maintaining its relative position. During the last flight, six capture attempts were made, two of which were successful. The four misses demonstrated excellent characteristics, the receiver retreating from the drogue in a controlled, safe, and predictable manner that precluded contact between the drogue and the receiver aircraft. The position of the receiver aircraft when engaged and in position for refueling was found to be 5.5 to 8.5 ft low of the ideal position. The controller inputs to the F/A-18 were found to be extremely small.

  14. Airborne Optical Communications Demonstrator Design And Preflight Test Results

    NASA Technical Reports Server (NTRS)

    Biswas, Abhijit; Page, N.; Neal, J.; Zhu, D.; Wright, M.; Ovtiz, G.; Farr, W. H.; Hernnzati, H.

    2005-01-01

    A second generation optical communications demonstrator (OCD-2) intended for airborne applications like air-to-ground and air-to-air optical links is under development at JPL. This development provides the capability for unidirectional high data rate (2.5-Gbps) transmission at 1550-nm, with the ability to receive an 810-nm beacon to aid acquisition pointing and tracking. The transmitted beam width is nominally 200-(micro)rad. A 3x3 degree coarse field-of-view (FOV) acquisition sensor with a much smaller 3-mrad FOV tracking sensor is incorporated. The OCD-2 optical head will be integrated to a high performance gimbal turret assembly capable of providing pointing stability of 5- microradians from an airborne platform. Other parts of OCD-2 include a cable harness, connecting the optical head in the gimbal turret assembly to a rugged electronics box. The electronics box will house: command and control processors, laser transmitter, data-generation-electronics, power conversion/distribution hardware and state-of-health monitors. The entire assembly will be integrated and laboratory tested prior to a planned flight demonstrations.

  15. Validation of the Short Form of the Academic Procrastination Scale.

    PubMed

    Yockey, Ronald D

    2016-02-01

    The factor structure, internal consistency reliability, and convergent validity of the five-item Academic Procrastination Scale-Short Form was investigated on an ethnically diverse sample of college students. The results provided support for the Academic Procrastination Scale-Short Form as a unidimensional measure of academic procrastination, which possessed good internal consistency reliability in this sample of 282 students. The scale also demonstrated good convergent validity, with moderate to large correlations with both the Procrastination Assessment Scale-Students and the Tuckman Procrastination Scale. Implications of the results are discussed and recommendations for future work provided.

  16. Urdu translation of the Hamilton Rating Scale for Depression: Results of a validation study

    PubMed Central

    Hashmi, Ali M.; Naz, Shahana; Asif, Aftab; Khawaja, Imran S.

    2016-01-01

    Objective: To develop a standardized validated version of the Hamilton Rating Scale for Depression (HAM-D) in Urdu. Methods: After translation of the HAM-D into the Urdu language following standard guidelines, the final Urdu version (HAM-D-U) was administered to 160 depressed outpatients. Inter-item correlation was assessed by calculating Cronbach alpha. Correlation between HAM-D-U scores at baseline and after a 2-week interval was evaluated for test-retest reliability. Moreover, scores of two clinicians on HAM-D-U were compared for inter-rater reliability. For establishing concurrent validity, scores of HAM-D-U and BDI-U were compared by using Spearman correlation coefficient. The study was conducted at Mayo Hospital, Lahore, from May to December 2014. Results: The Cronbach alpha for HAM-D-U was 0.71. Composite scores for HAM-D-U at baseline and after a 2-week interval were also highly correlated with each other (Spearman correlation coefficient 0.83, p-value < 0.01) indicating good test-retest reliability. Composite scores for HAM-D-U and BDI-U were positively correlated with each other (Spearman correlation coefficient 0.85, p < 0.01) indicating good concurrent validity. Scores of two clinicians for HAM-D-U were also positively correlated (Spearman correlation coefficient 0.82, p-value < 0.01) indicated good inter-rater reliability. Conclusion: The HAM-D-U is a valid and reliable instrument for the assessment of Depression. It shows good inter-rater and test-retest reliability. The HAM-D-U can be a tool either for clinical management or research. PMID:28083049

  17. PROMIS measures of pain, fatigue, negative affect, physical function, and social function demonstrated clinical validity across a range of chronic conditions.

    PubMed

    Cook, Karon F; Jensen, Sally E; Schalet, Benjamin D; Beaumont, Jennifer L; Amtmann, Dagmar; Czajkowski, Susan; Dewalt, Darren A; Fries, James F; Pilkonis, Paul A; Reeve, Bryce B; Stone, Arthur A; Weinfurt, Kevin P; Cella, David

    2016-05-01

    To present an overview of a series of studies in which the clinical validity of the National Institutes of Health's Patient Reported Outcome Measurement Information System (NIH; PROMIS) measures was evaluated, by domain, across six clinical populations. Approximately 1,500 individuals at baseline and 1,300 at follow-up completed PROMIS measures. The analyses reported in this issue were conducted post hoc, pooling data across six previous studies, and accommodating the different designs of the six, within-condition, parent studies. Changes in T-scores, standardized response means, and effect sizes were calculated in each study. When a parent study design allowed, known groups validity was calculated using a linear mixed model. The results provide substantial support for the clinical validity of nine PROMIS measures in a range of chronic conditions. The cross-condition focus of the analyses provided a unique and multifaceted perspective on how PROMIS measures function in "real-world" clinical settings and provides external anchors that can support comparative effectiveness research. The current body of clinical validity evidence for the nine PROMIS measures indicates the success of NIH PROMIS in developing measures that are effective across a range of chronic conditions. Copyright © 2016 Elsevier Inc. All rights reserved.

  18. Demonstration of Corrosion-Resistant Hybrid Composite Bridge Beams for Structural Applications

    DTIC Science & Technology

    2016-09-01

    result of corrosion of the steel support structures or the reinforcing bar in the concrete. The application of corrosion-resistant technology can...demonstrated and validated a corrosion-resistant hybrid-composite beam (HCB) for the reconstruction of a one span of a traditional steel and...concrete bridge at Fort Knox, Kentucky. The HCBs were installed on half of the bridge, and conventional steel beams were installed on the other half

  19. Construct validity of adolescents' self-reported big five personality traits: importance of conceptual breadth and initial validation of a short measure.

    PubMed

    Morizot, Julien

    2014-10-01

    While there are a number of short personality trait measures that have been validated for use with adults, few are specifically validated for use with adolescents. To trust such measures, it must be demonstrated that they have adequate construct validity. According to the view of construct validity as a unifying form of validity requiring the integration of different complementary sources of information, this article reports the evaluation of content, factor, convergent, and criterion validities as well as reliability of adolescents' self-reported personality traits. Moreover, this study sought to address an inherent potential limitation of short personality trait measures, namely their limited conceptual breadth. In this study, starting with items from a known measure, after the language-level was adjusted for use with adolescents, items tapping fundamental primary traits were added to determine the impact of added conceptual breadth on the psychometric properties of the scales. The resulting new measure was named the Big Five Personality Trait Short Questionnaire (BFPTSQ). A group of expert judges considered the items to have adequate content validity. Using data from a community sample of early adolescents, the results confirmed the factor validity of the Big Five structure in adolescence as well as its measurement invariance across genders. More important, the added items did improve the convergent and criterion validities of the scales, but did not negatively affect their reliability. This study supports the construct validity of adolescents' self-reported personality traits and points to the importance of conceptual breadth in short personality measures. © The Author(s) 2014.

  20. Ford Plug-In Project: Bringing PHEVs to Market Demonstration and Validation Project

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    D'Annunzio, Julie; Slezak, Lee; Conley, John Jason

    2014-03-26

    This project is in support of our national goal to reduce our dependence on fossil fuels. By supporting efforts that contribute toward the successful mass production of plug-in hybrid electric vehicles, our nation’s transportation-related fuel consumption can be offset with energy from the grid. Over four and a half years ago, when this project was originally initiated, plug-in electric vehicles were not readily available in the mass marketplace. Through the creation of a 21 unit plug-in hybrid vehicle fleet, this program was designed to demonstrate the feasibility of the technology and to help build cross-industry familiarity with the technology andmore » interface of this technology with the grid. Ford Escape PHEV Demonstration Fleet 3 March 26, 2014 Since then, however, plug-in vehicles have become increasingly more commonplace in the market. Ford, itself, now offers an all-electric vehicle and two plug-in hybrid vehicles in North America and has announced a third plug-in vehicle offering for Europe. Lessons learned from this project have helped in these production vehicle launches and are mentioned throughout this report. While the technology of plugging in a vehicle to charge a high voltage battery with energy from the grid is now in production, the ability for vehicle-to-grid or bi-directional energy flow was farther away than originally expected. Several technical, regulatory and potential safety issues prevented progressing the vehicle-to-grid energy flow (V2G) demonstration and, after a review with the DOE, V2G was removed from this demonstration project. Also proving challenging were communications between a plug-in vehicle and the grid or smart meter. While this project successfully demonstrated the vehicle to smart meter interface, cross-industry and regulatory work is still needed to define the vehicle-to-grid communication interface.« less

  1. The Hyper-X Flight Systems Validation Program

    NASA Technical Reports Server (NTRS)

    Redifer, Matthew; Lin, Yohan; Bessent, Courtney Amos; Barklow, Carole

    2007-01-01

    For the Hyper-X/X-43A program, the development of a comprehensive validation test plan played an integral part in the success of the mission. The goal was to demonstrate hypersonic propulsion technologies by flight testing an airframe-integrated scramjet engine. Preparation for flight involved both verification and validation testing. By definition, verification is the process of assuring that the product meets design requirements; whereas validation is the process of assuring that the design meets mission requirements for the intended environment. This report presents an overview of the program with emphasis on the validation efforts. It includes topics such as hardware-in-the-loop, failure modes and effects, aircraft-in-the-loop, plugs-out, power characterization, antenna pattern, integration, combined systems, captive carry, and flight testing. Where applicable, test results are also discussed. The report provides a brief description of the flight systems onboard the X-43A research vehicle and an introduction to the ground support equipment required to execute the validation plan. The intent is to provide validation concepts that are applicable to current, follow-on, and next generation vehicles that share the hybrid spacecraft and aircraft characteristics of the Hyper-X vehicle.

  2. ENSURF: multi-model sea level forecast - implementation and validation results for the IBIROOS and Western Mediterranean regions

    NASA Astrophysics Data System (ADS)

    Pérez, B.; Brouwer, R.; Beckers, J.; Paradis, D.; Balseiro, C.; Lyons, K.; Cure, M.; Sotillo, M. G.; Hackett, B.; Verlaan, M.; Fanjul, E. A.

    2012-03-01

    ENSURF (Ensemble SURge Forecast) is a multi-model application for sea level forecast that makes use of several storm surge or circulation models and near-real time tide gauge data in the region, with the following main goals: 1. providing easy access to existing forecasts, as well as to its performance and model validation, by means of an adequate visualization tool; 2. generation of better forecasts of sea level, including confidence intervals, by means of the Bayesian Model Average technique (BMA). The Bayesian Model Average technique generates an overall forecast probability density function (PDF) by making a weighted average of the individual forecasts PDF's; the weights represent the Bayesian likelihood that a model will give the correct forecast and are continuously updated based on the performance of the models during a recent training period. This implies the technique needs the availability of sea level data from tide gauges in near-real time. The system was implemented for the European Atlantic facade (IBIROOS region) and Western Mediterranean coast based on the MATROOS visualization tool developed by Deltares. Results of validation of the different models and BMA implementation for the main harbours are presented for these regions where this kind of activity is performed for the first time. The system is currently operational at Puertos del Estado and has proved to be useful in the detection of calibration problems in some of the circulation models, in the identification of the systematic differences between baroclinic and barotropic models for sea level forecasts and to demonstrate the feasibility of providing an overall probabilistic forecast, based on the BMA method.

  3. ESTCP Live Site Demonstrations Former Camp Beale, Marysville, CA

    DTIC Science & Technology

    2011-08-23

    ESTCP Live Site Demonstrations Former Camp Beale Marysville, CA ESTCP MR-201165 Demonstration Data Report Former Camp Beale...with a collection of information if it does not display a currently valid OMB control number. 1. REPORT DATE AUG 2011 2 . REPORT TYPE N/A 3. DATES...COVERED - 4. TITLE AND SUBTITLE ESTCP Live Site Demonstrations Former Camp Beale Marysville, CA 5a. CONTRACT NUMBER 5b. GRANT NUMBER 5c

  4. Functional performance following selective posterior rhizotomy: long-term results determined using a validated evaluative measure.

    PubMed

    Mittal, Sandeep; Farmer, Jean-Pierre; Al-Atassi, Borhan; Montpetit, Kathleen; Gervais, Nathalie; Poulin, Chantal; Benaroch, Thierry E; Cantin, Marie-André

    2002-09-01

    Selective posterior rhizotomy (SPR) may result in considerable benefit for children with spastic cerebral palsy. To date, however, there have been few studies in which validated functional outcome measures have been used to report surgical results beyond 3 years. The authors analyzed data obtained from the McGill Rhizotomy Database to determine long-term functional performance outcomes in patients who underwent lumbosacral dorsal rhizotomy performed using intraoperative electrophysiological monitoring. The study population was composed of children with debilitating spasticity who underwent SPR and were evaluated by a multidisciplinary team preoperatively and at 6 months and 1 year postoperatively. Quantitative standardized assessments of activities of daily living (ADL) were obtained using the Pediatric Evaluation of Disability Inventory (PEDI). Of 57 patients who met the entry criteria for the study, 41 completed the 3-year assessments and 30 completed the 5-year assessments. Statistical analysis demonstrated significant improvement in the mobility and self-care domains of the functional skills dimension at 1 year after SPR. The preoperative and 1-, 3-, and 5-year postoperative scaled scores for the mobility domain were 56, 64, 77.2, and 77.8, respectively. The scaled score for the self-care domain increased from 59 presurgery to 67.9, 81.6, and 82.4 at the 1-, 3-, and 5-year postoperative assessments, respectively. The results of this study support the presence of significant improvements in functional performance, based on PEDI scores obtained 1 year after SPR. The improvements persisted at the 3- and 5-year follow-up examinations. The authors conclude that SPR performed using intraoperative stimulation is valuable in the augmentation of motor function and self-care skills essential to the performance of ADL.

  5. A Note on Economic Content and Test Validity.

    ERIC Educational Resources Information Center

    Soper, John C.; Brenneke, Judith Staley

    1987-01-01

    Offers practical tips on how teachers can determine whether classroom tests are actually measuring what they are designed to measure. Discusses criterion-related validity, construct validity, and content validity. Demonstrates how to determine the degree of content validity a particular test may have for a particular course or unit. (Author/DH)

  6. Reliability and validity of the Wolfram Unified Rating Scale (WURS)

    PubMed Central

    2012-01-01

    Background Wolfram syndrome (WFS) is a rare, neurodegenerative disease that typically presents with childhood onset insulin dependent diabetes mellitus, followed by optic atrophy, diabetes insipidus, deafness, and neurological and psychiatric dysfunction. There is no cure for the disease, but recent advances in research have improved understanding of the disease course. Measuring disease severity and progression with reliable and validated tools is a prerequisite for clinical trials of any new intervention for neurodegenerative conditions. To this end, we developed the Wolfram Unified Rating Scale (WURS) to measure the severity and individual variability of WFS symptoms. The aim of this study is to develop and test the reliability and validity of the Wolfram Unified Rating Scale (WURS). Methods A rating scale of disease severity in WFS was developed by modifying a standardized assessment for another neurodegenerative condition (Batten disease). WFS experts scored the representativeness of WURS items for the disease. The WURS was administered to 13 individuals with WFS (6-25 years of age). Motor, balance, mood and quality of life were also evaluated with standard instruments. Inter-rater reliability, internal consistency reliability, concurrent, predictive and content validity of the WURS were calculated. Results The WURS had high inter-rater reliability (ICCs>.93), moderate to high internal consistency reliability (Cronbach’s α = 0.78-0.91) and demonstrated good concurrent and predictive validity. There were significant correlations between the WURS Physical Assessment and motor and balance tests (rs>.67, p<.03), between the WURS Behavioral Scale and reports of mood and behavior (rs>.76, p<.04) and between WURS Total scores and quality of life (rs=-.86, p=.001). The WURS demonstrated acceptable content validity (Scale-Content Validity Index=0.83). Conclusions These preliminary findings demonstrate that the WURS has acceptable reliability and validity and

  7. Two Validated Ways of Improving the Ability of Decision-Making in Emergencies; Results from a Literature Review

    PubMed Central

    Khorram-Manesh, Amir; Berlin, Johan; Carlström, Eric

    2016-01-01

    The aim of the current review wasto study the existing knowledge about decision-making and to identify and describe validated training tools.A comprehensive literature review was conducted by using the following keywords: decision-making, emergencies, disasters, crisis management, training, exercises, simulation, validated, real-time, command and control, communication, collaboration, and multi-disciplinary in combination or as an isolated word. Two validated training systems developed in Sweden, 3 level collaboration (3LC) and MacSim, were identified and studied in light of the literature review in order to identify how decision-making can be trained. The training models fulfilled six of the eight identified characteristics of training for decision-making.Based on the results, these training models contained methods suitable to train for decision-making. PMID:27878123

  8. Assessing attitude toward same-sex marriage: scale development and validation.

    PubMed

    Lannutti, Pamela J; Lachlan, Kenneth A

    2007-01-01

    This paper reports the results of three studies conducted to develop, refine, and validate a scale which assessed heterosexual adults' attitudes toward same-sex marriage, the Attitude Toward Same-Sex Marriage Scale (ASSMS). The need for such a scale is evidenced in the increasing importance of same-sex marriage in the political arena of the United States and other nations, as well as the growing body of empirical research examining same-sex marriage and related issues (e.g., Lannutti, 2005; Solomon, Rothblum, & Balsam, 2004). The results demonstrate strong reliability, convergent validity, and predictive validity for the ASSMS and suggest that the ASSMS may be adapted to measure attitudes toward civil unions and other forms of relational recognition for same-sex couples. Gender comparisons using the validated scale showed that in college and non-college samples, women had a significantly more positive attitude toward same-sex marriage than did men.

  9. Validation of new psychosocial factors questionnaires: a Colombian national study.

    PubMed

    Villalobos, Gloria H; Vargas, Angélica M; Rondón, Martin A; Felknor, Sarah A

    2013-01-01

    The study of workers' health problems possibly associated with stressful conditions requires valid and reliable tools for monitoring risk factors. The present study validates two questionnaires to assess psychosocial risk factors for stress-related illnesses within a sample of Colombian workers. The validation process was based on a representative sample survey of 2,360 Colombian employees, aged 18-70 years. Worker response rate was 90%; 46% of the responders were women. Internal consistency was calculated, construct validity was tested with factor analysis and concurrent validity was tested with Spearman correlations. The questionnaires demonstrated adequate reliability (0.88-0.95). Factor analysis confirmed the dimensions proposed in the measurement model. Concurrent validity resulted in significant correlations with stress and health symptoms. "Work and Non-work Psychosocial Factors Questionnaires" were found to be valid and reliable for the assessment of workers' psychosocial factors, and they provide information for research and intervention. Copyright © 2012 Wiley Periodicals, Inc.

  10. Validity for What? The Peril of Overclarifying

    ERIC Educational Resources Information Center

    Murphy, Kevin R.

    2012-01-01

    As Paul Newton so ably demonstrates, the concept of validity is both important and problematic. Over the last several decades, a consensus definition of validity has emerged; the current edition of "Standards for Educational and Psychological Testing" notes, "Validity refers to the degree to which evidence and theory support the interpretations of…

  11. Validation of Robotic Surgery Simulator (RoSS).

    PubMed

    Kesavadas, Thenkurussi; Stegemann, Andrew; Sathyaseelan, Gughan; Chowriappa, Ashirwad; Srimathveeravalli, Govindarajan; Seixas-Mikelus, Stéfanie; Chandrasekhar, Rameella; Wilding, Gregory; Guru, Khurshid

    2011-01-01

    Recent growth of daVinci Robotic Surgical System as a minimally invasive surgery tool has led to a call for better training of future surgeons. In this paper, a new virtual reality simulator, called RoSS is presented. Initial results from two studies - face and content validity, are very encouraging. 90% of the cohort of expert robotic surgeons felt that the simulator was excellent or somewhat close to the touch and feel of the daVinci console. Content validity of the simulator received 90% approval in some cases. These studies demonstrate that RoSS has the potential of becoming an important training tool for the daVinci surgical robot.

  12. Validation of the ArthroS virtual reality simulator for arthroscopic skills.

    PubMed

    Stunt, J J; Kerkhoffs, G M M J; van Dijk, C N; Tuijthof, G J M

    2015-11-01

    Virtual reality simulator training has become important for acquiring arthroscopic skills. A new simulator for knee arthroscopy ArthroS™ has been developed. The purpose of this study was to demonstrate face and construct validity, executed according to a protocol used previously to validate arthroscopic simulators. Twenty-seven participants were divided into three groups having different levels of arthroscopic experience. Participants answered questions regarding general information and the outer appearance of the simulator for face validity. Construct validity was assessed with one standardized navigation task. Face validity, educational value and user friendliness were further determined by giving participants three exercises and by asking them to fill out the questionnaire. Construct validity was demonstrated between experts and beginners. Median task times were not significantly different for all repetitions between novices and intermediates, and between intermediates and experts. Median face validity was 8.3 for the outer appearance, 6.5 for the intra-articular joint and 4.7 for surgical instruments. Educational value and user friendliness were perceived as nonsatisfactory, especially because of the lack of tactile feedback. The ArthroS™ demonstrated construct validity between novices and experts, but did not demonstrate full face validity. Future improvements should be mainly focused on the development of tactile feedback. It is necessary that a newly presented simulator is validated to prove it actually contributes to proficiency of skills.

  13. PROMIS fatigue, pain intensity, pain interference, pain behavior, physical function, depression, anxiety, and anger scales demonstrate ecological validity.

    PubMed

    Stone, Arthur A; Broderick, Joan E; Junghaenel, Doerte U; Schneider, Stefan; Schwartz, Joseph E

    2016-06-01

    Ecological validity refers to the degree to which instruments faithfully capture information in respondents' natural environments. We examined the ecological validity of eight instruments from the Patient Reported Outcomes Measurement Information System (PROMIS), most of which use 7-day reporting periods, by comparing PROMIS scores with daily diary data as a standard. Five groups of approximately 100 respondents each completed daily diaries and weekly PROMIS instruments for 4 consecutive weeks: community residents; osteoarthritis patients; women experiencing premenstrual syndrome; men undergoing hernia surgery; and breast cancer patients receiving chemotherapy. The last three groups experienced events (menses, surgery, or chemotherapy, respectively) at standardized times in the protocol to examine symptom changes attributable to these events. We examined the ability of the PROMIS scales to replicate between-group differences in diaries, to replicate week-to-week changes in diaries, and the correlation between diary and PROMIS scales. As a secondary aim, we examined known-group differences with the PROMIS measures. All three types of ecological validity were strongly confirmed, as was known-group validity for the PROMIS recall scales. This study adds to the growing literature supporting the reliability and validity of the family of PROMIS instruments. Copyright © 2015 Elsevier Inc. All rights reserved.

  14. Validation of an Integrated Airframe and Turbofan Engine Simulation for Evaluation of Propulsion Control Modes

    NASA Technical Reports Server (NTRS)

    Litt, Jonathan S.; Sowers, T Shane; Liu, Yuan; Owen, A. Karl; Guo, Ten-Huei

    2015-01-01

    The National Aeronautics and Space Administration (NASA) has developed independent airframe and engine models that have been integrated into a single real-time aircraft simulation for piloted evaluation of propulsion control algorithms. In order to have confidence in the results of these evaluations, the integrated simulation must be validated to demonstrate that its behavior is realistic and that it meets the appropriate Federal Aviation Administration (FAA) certification requirements for aircraft. The paper describes the test procedures and results, demonstrating that the integrated simulation generally meets the FAA requirements and is thus a valid testbed for evaluation of propulsion control modes.

  15. Validation of the Spanish Addiction Severity Index Multimedia Version (S-ASI-MV).

    PubMed

    Butler, Stephen F; Redondo, José Pedro; Fernandez, Kathrine C; Villapiano, Albert

    2009-01-01

    This study aimed to develop and test the reliability and validity of a Spanish adaptation of the ASI-MV, a computer administered version of the Addiction Severity Index, called the S-ASI-MV. Participants were 185 native Spanish-speaking adult clients from substance abuse treatment facilities serving Spanish-speaking clients in Florida, New Mexico, California, and Puerto Rico. Participants were administered the S-ASI-MV as well as Spanish versions of the general health subscale of the SF-36, the work and family unit subscales of the Social Adjustment Scale Self-Report, the Michigan Alcohol Screening Test, the alcohol and drug subscales of the Personality Assessment Inventory, and the Hopkins Symptom Checklist-90. Three-to-five-day test-retest reliability was examined along with criterion validity, convergent/discriminant validity, and factorial validity. Measurement invariance between the English and Spanish versions of the ASI-MV was also examined. The S-ASI-MV demonstrated good test-retest reliability (ICCs for composite scores between .59 and .93), criterion validity (rs for composite scores between .66 and .87), and convergent/discriminant validity. Factorial validity and measurement invariance were demonstrated. These results compared favorably with those reported for the original interviewer version of the ASI and the English version of the ASI-MV.

  16. Affordable Flight Demonstration of the GTX Air-Breathing SSTO Vehicle Concept

    NASA Technical Reports Server (NTRS)

    Krivanek, Thomas M.; Roche, Joseph M.; Riehl, John P.; Kosareo, Daniel N.

    2002-01-01

    The rocket based combined cycle (RBCC) powered single-stage-to-orbit (SSTO) reusable launch vehicle has the potential to significantly reduce the total cost per pound for orbital payload missions. To validate overall system performance, a flight demonstration must be performed. This paper presents an overview of the first phase of a flight demonstration program for the GTX SSTO vehicle concept. Phase 1 will validate the propulsion performance of the vehicle configuration over the supersonic and hypersonic airbreathing portions of the trajectory. The focus and goal of Phase 1 is to demonstrate the integration and performance of the propulsion system flowpath with the vehicle aerodynamics over the air-breathing trajectory. This demonstrator vehicle will have dual mode ramjet/scramjets, which include the inlet, combustor, and nozzle with geometrically scaled aerodynamic surface outer mold lines (OML) defining the forebody, boundary layer diverter, wings, and tail. The primary objective of this study is to demonstrate propulsion system performance and operability including the ram to scram transition, as well as to validate vehicle aerodynamics and propulsion airframe integration. To minimize overall risk and development cost the effort will incorporate proven materials, use existing turbomachinery in the propellant delivery systems, launch from an existing unmanned remote launch facility, and use basic vehicle recovery techniques to minimize control and landing requirements. A second phase would demonstrate propulsion performance across all critical portions of a space launch trajectory (lift off through transition to all-rocket) integrated with flight-like vehicle systems.

  17. Cloud computing and validation of expandable in silico livers.

    PubMed

    Ropella, Glen E P; Hunt, C Anthony

    2010-12-03

    In Silico Livers (ISLs) are works in progress. They are used to challenge multilevel, multi-attribute, mechanistic hypotheses about the hepatic disposition of xenobiotics coupled with hepatic responses. To enhance ISL-to-liver mappings, we added discrete time metabolism, biliary elimination, and bolus dosing features to a previously validated ISL and initiated re-validated experiments that required scaling experiments to use more simulated lobules than previously, more than could be achieved using the local cluster technology. Rather than dramatically increasing the size of our local cluster we undertook the re-validation experiments using the Amazon EC2 cloud platform. So doing required demonstrating the efficacy of scaling a simulation to use more cluster nodes and assessing the scientific equivalence of local cluster validation experiments with those executed using the cloud platform. The local cluster technology was duplicated in the Amazon EC2 cloud platform. Synthetic modeling protocols were followed to identify a successful parameterization. Experiment sample sizes (number of simulated lobules) on both platforms were 49, 70, 84, and 152 (cloud only). Experimental indistinguishability was demonstrated for ISL outflow profiles of diltiazem using both platforms for experiments consisting of 84 or more samples. The process was analogous to demonstration of results equivalency from two different wet-labs. The results provide additional evidence that disposition simulations using ISLs can cover the behavior space of liver experiments in distinct experimental contexts (there is in silico-to-wet-lab phenotype similarity). The scientific value of experimenting with multiscale biomedical models has been limited to research groups with access to computer clusters. The availability of cloud technology coupled with the evidence of scientific equivalency has lowered the barrier and will greatly facilitate model sharing as well as provide straightforward tools for scaling

  18. The Alcohol Relapse Situation Appraisal Questionnaire: Development and Validation

    PubMed Central

    Martin, Rosemarie A.; MacKinnon, Selene M.; Johnson, Jennifer E.; Myers, Mark G.; Cook, Travis A. R.; Rohsenow, Damaris J.

    2011-01-01

    Background The role of cognitive appraisal of the threat of alcohol relapse has received little attention. A previous instrument, the Relapse Situation Appraisal Questionnaire (RSAQ), was developed to assess cocaine users’ primary appraisal of the threat of situations posing a high risk for cocaine relapse. The purpose of the present study was to modify the RSAQ in order to measure primary appraisal in situations involving a high risk for alcohol relapse. Methods The development and psychometric properties of this instrument, the Alcohol Relapse Situation Appraisal Questionnaire (A-RSAQ), were examined with two samples of abstinent adults with alcohol abuse or dependence. Factor structure and validity were examined in Study 1 (N=104). Confirmation of the factor structure and predictive validity were assessed in Study 2 (N=161). Results Results demonstrated construct, discriminant and predictive validity and reliability of the A-RSAQ. Discussion Results support the important role of primary appraisal of degree of risk in alcohol relapse situations. PMID:21237586

  19. Multiple Versus Single Set Validation of Multivariate Models to Avoid Mistakes.

    PubMed

    Harrington, Peter de Boves

    2018-01-02

    Validation of multivariate models is of current importance for a wide range of chemical applications. Although important, it is neglected. The common practice is to use a single external validation set for evaluation. This approach is deficient and may mislead investigators with results that are specific to the single validation set of data. In addition, no statistics are available regarding the precision of a derived figure of merit (FOM). A statistical approach using bootstrapped Latin partitions is advocated. This validation method makes an efficient use of the data because each object is used once for validation. It was reviewed a decade earlier but primarily for the optimization of chemometric models this review presents the reasons it should be used for generalized statistical validation. Average FOMs with confidence intervals are reported and powerful, matched-sample statistics may be applied for comparing models and methods. Examples demonstrate the problems with single validation sets.

  20. Experimental Demonstration of Frequency Regulation by Commercial Buildings – Part II: Results and Performance Evaluation

    DOE PAGES

    Vrettos, Evangelos; Kara, Emre Can; MacDonald, Jason; ...

    2016-11-15

    This paper is the second part of a two-part series presenting the results from an experimental demonstration of frequency regulation in a commercial building test facility. We developed relevant building models and designed a hierarchical controller for reserve scheduling, building climate control and frequency regulation in Part I. In Part II, we introduce the communication architecture and experiment settings, and present extensive experimental results under frequency regulation. More specifically, we compute the day-ahead reserve capacity of the test facility under different assumptions and conditions. Furthermore, we demonstrate the ability of model predictive control to satisfy comfort constraints under frequency regulation,more » and show that fan speed control can track the fast-moving RegD signal of the Pennsylvania, Jersey, and Maryland Power Market (PJM) very accurately. In addition, we discuss potential effects of frequency regulation on building operation (e.g., increase in energy consumption, oscillations in supply air temperature, and effect on chiller cycling), and provide suggestions for real-world implementation projects. Our results show that hierarchical control is appropriate for frequency regulation from commercial buildings.« less

  1. Production of high-fidelity electropherograms results in improved and consistent DNA interpretation: Standardizing the forensic validation process.

    PubMed

    Peters, Kelsey C; Swaminathan, Harish; Sheehan, Jennifer; Duffy, Ken R; Lun, Desmond S; Grgicak, Catherine M

    2017-11-01

    Samples containing low-copy numbers of DNA are routinely encountered in casework. The signal acquired from these sample types can be difficult to interpret as they do not always contain all of the genotypic information from each contributor, where the loss of genetic information is associated with sampling and detection effects. The present work focuses on developing a validation scheme to aid in mitigating the effects of the latter. We establish a scheme designed to simultaneously improve signal resolution and detection rates without costly large-scale experimental validation studies by applying a combined simulation and experimental based approach. Specifically, we parameterize an in silico DNA pipeline with experimental data acquired from the laboratory and use this to evaluate multifarious scenarios in a cost-effective manner. Metrics such as signal 1copy -to-noise resolution, false positive and false negative signal detection rates are used to select tenable laboratory parameters that result in high-fidelity signal in the single-copy regime. We demonstrate that the metrics acquired from simulation are consistent with experimental data obtained from two capillary electrophoresis platforms and various injection parameters. Once good resolution is obtained, analytical thresholds can be determined using detection error tradeoff analysis, if necessary. Decreasing the limit of detection of the forensic process to one copy of DNA is a powerful mechanism by which to increase the information content on minor components of a mixture, which is particularly important for probabilistic system inference. If the forensic pipeline is engineered such that high-fidelity electropherogram signal is obtained, then the likelihood ratio (LR) of a true contributor increases and the probability that the LR of a randomly chosen person is greater than one decreases. This is, potentially, the first step towards standardization of the analytical pipeline across operational laboratories

  2. The 2.5 bit/detected photon demonstration program: Phase 2 and 3 experimental results

    NASA Technical Reports Server (NTRS)

    Katz, J.

    1982-01-01

    The experimental program for laboratory demonstration of and energy efficient optical communication channel operating at a rate of 2.5 bits/detected photon is described. Results of the uncoded PPM channel performance are presented. It is indicated that the throughput efficiency can be achieved not only with a Reed-Solomon code as originally predicted, but with a less complex code as well.

  3. Road surface erosion on the Jackson Demonstration State Forest: results of a pilot study

    Treesearch

    Brian Barrett; Rosemary Kosaka; David. Tomberlin

    2012-01-01

    This paper presents results of a 3 year pilot study of surface erosion on forest roads in the Jackson Demonstration State Forest in California’s coastal redwood region. Ten road segments representing a range of surface, grade, and ditch conditions were selected for the study. At each segment, settling basins with tipping buckets were installed to measure...

  4. Development of large aperture telescope technology (LATT): test results on a demonstrator bread-board

    NASA Astrophysics Data System (ADS)

    Briguglio, R.; Xompero, M.; Riccardi, A.; Lisi, F.; Duò, F.; Vettore, C.; Gallieni, D.; Tintori, M.; Lazzarini, P.; Patauner, C.; Biasi, R.; D'Amato, F.; Pucci, M.; Pereira do Carmo, João.

    2017-11-01

    The concept of a low areal density primary mirror, actively controlled by actuators, has been investigated through a demonstration prototype. A spherical mirror (400 mm diameter, 2.7 Kg mass) has been manufactured and tested in laboratory and on the optical bench, to verify performance, controllability and optical quality. In the present paper we will describe the prototype and the test results.

  5. Impact of selective posterior rhizotomy on fine motor skills. Long-term results using a validated evaluative measure.

    PubMed

    Mittal, Sandeep; Farmer, Jean-Pierre; Al-Atassi, Borhan; Montpetit, Kathleen; Gervais, Nathalie; Poulin, Chantal; Cantin, Marie-André; Benaroch, Thierry E

    2002-03-01

    Suprasegmental effects following selective posterior rhizotomy have been frequently reported. However, few studies have used validated functional outcome measures to report the surgical results beyond 3 years. The authors analyzed data obtained from the McGill Rhizotomy Database to determine the long-term impact of lumbosacral dorsal rhizotomy on fine motor skills. The study population comprised children with debilitating spasticity who underwent SPR and were evaluated by a multidisciplinary team preoperatively, at 6 months and 1 year postoperatively. Quantitative standardized assessments of upper extremity function were obtained using the fine motor skills section of the Peabody Developmental Motor Scales (PDMS) test. Of 70 patients who met the entry criteria for the study, 45 and 25 completed the 3- and 5-year assessments, respectively. Statistical analysis demonstrated significant improvements in grasping, hand use, eye-hand coordination, and manual dexterity at 1 year after SPR. More importantly, all improvements were maintained at 3 and 5 years following SPR. This study supports that significant improvements in upper extremity fine motor function using the PDMS evaluative measure are present after SPR and that these suprasegmental benefits are durable. Copyright 2002 S. Karger AG, Basel

  6. Hopes and Cautions for Instrument-Based Evaluation of Consent Capacity: Results of a Construct Validity Study of Three Instruments

    PubMed Central

    Moye, Jennifer; Azar, Annin R.; Karel, Michele J.; Gurrera, Ronald J.

    2016-01-01

    Does instrument based evaluation of consent capacity increase the precision and validity of competency assessment or does ostensible precision provide a false sense of confidence without in fact improving validity? In this paper we critically examine the evidence for construct validity of three instruments for measuring four functional abilities important in consent capacity: understanding, appreciation, reasoning, and expressing a choice. Instrument based assessment of these abilities is compared through investigation of a multi-trait multi-method matrix in 88 older adults with mild to moderate dementia. Results find variable support for validity. There appears to be strong evidence for good hetero-method validity for the measurement of understanding, mixed evidence for validity in the measurement of reasoning, and strong evidence for poor hetero-method validity for the concepts of appreciation and expressing a choice, although the latter is likely due to extreme range restrictions. The development of empirically based tools for use in capacity evaluation should ultimately enhance the reliability and validity of assessment, yet clearly more research is needed to define and measure the constructs of decisional capacity. We would also emphasize that instrument based assessment of capacity is only one part of a comprehensive evaluation of competency which includes consideration of diagnosis, psychiatric and/or cognitive symptomatology, risk involved in the situation, and individual and cultural differences. PMID:27330455

  7. Omnetric Group Demonstrates Distributed Grid-Edge Control Hierarchy at NREL

    Science.gov Websites

    | Energy Systems Integration Facility | NREL Omnetric Group Omnetric Group Demonstrates Group demonstrated a distributed control hierarchy-based on an open field message bus (OpenFMB resources. OMNETRIC Group first developed and validated the system in the ESIF with a combination of

  8. A systematic review of validated sinus surgery simulators.

    PubMed

    Stew, B; Kao, S S-T; Dharmawardana, N; Ooi, E H

    2018-06-01

    Simulation provides a safe and effective opportunity to develop surgical skills. A variety of endoscopic sinus surgery (ESS) simulators has been described in the literature. Validation of these simulators allows for effective utilisation in training. To conduct a systematic review of the published literature to analyse the evidence for validated ESS simulation. Pubmed, Embase, Cochrane and Cinahl were searched from inception of the databases to 11 January 2017. Twelve thousand five hundred and sixteen articles were retrieved of which 10 112 were screened following the removal of duplicates. Thirty-eight full-text articles were reviewed after meeting search criteria. Evidence of face, content, construct, discriminant and predictive validity was extracted. Twenty articles were included in the analysis describing 12 ESS simulators. Eleven of these simulators had undergone validation: 3 virtual reality, 7 physical bench models and 1 cadaveric simulator. Seven of the simulators were shown to have face validity, 7 had construct validity and 1 had predictive validity. None of the simulators demonstrated discriminate validity. This systematic review demonstrates that a number of ESS simulators have been comprehensively validated. Many of the validation processes, however, lack standardisation in outcome reporting, thus limiting a meta-analysis comparison between simulators. © 2017 John Wiley & Sons Ltd.

  9. The development and validation of the Physical Appearance Comparison Scale-Revised (PACS-R).

    PubMed

    Schaefer, Lauren M; Thompson, J Kevin

    2014-04-01

    The Physical Appearance Comparison Scale (PACS; Thompson, Heinberg, & Tantleff, 1991) was revised to assess appearance comparisons relevant to women and men in a wide variety of contexts. The revised scale (Physical Appearance Comparison Scale-Revised, PACS-R) was administered to 1176 college females. In Study 1, exploratory factor analysis and parallel analysis using one half of the sample suggested a single factor structure for the PACS-R. Study 2 utilized the remaining half of the sample to conduct confirmatory factor analysis, item analysis, and to examine the convergent validity of the scale. These analyses resulted in an 11-item measure that demonstrated excellent internal consistency and convergent validity with measures of body satisfaction, eating pathology, sociocultural influences on appearance, and self-esteem. Regression analyses demonstrated the utility of the PACS-R in predicting body satisfaction and eating pathology. Overall, results indicate that the PACS-R is a reliable and valid tool for assessing appearance comparison tendencies in women. Copyright © 2014. Published by Elsevier Ltd.

  10. Soil Moisture Active Passive Satellite Status and Recent Validation Results

    USDA-ARS?s Scientific Manuscript database

    The Soil Moisture Active Passive (SMAP) mission was launched in January, 2015 and began its calibration and validation (cal/val) phase in May, 2015. Cal/Val will begin with a focus on instrument measurements, brightness temperature and backscatter, and evolve to the geophysical products that include...

  11. Are Gender Differences in Perceived and Demonstrated Technology Literacy Significant? It Depends on the Model

    ERIC Educational Resources Information Center

    Hohlfeld, Tina N.; Ritzhaupt, Albert D.; Barron, Ann E.

    2013-01-01

    This paper examines gender differences related to Information and Communication Technology (ICT) literacy using two valid and internally consistent measures with eighth grade students (N = 1,513) from Florida public schools. The results of t test statistical analyses, which examined only gender differences in demonstrated and perceived ICT skills,…

  12. Learning by Demonstration for Motion Planning of Upper-Limb Exoskeletons.

    PubMed

    Lauretti, Clemente; Cordella, Francesca; Ciancio, Anna Lisa; Trigili, Emilio; Catalan, Jose Maria; Badesa, Francisco Javier; Crea, Simona; Pagliara, Silvio Marcello; Sterzi, Silvia; Vitiello, Nicola; Garcia Aracil, Nicolas; Zollo, Loredana

    2018-01-01

    The reference joint position of upper-limb exoskeletons is typically obtained by means of Cartesian motion planners and inverse kinematics algorithms with the inverse Jacobian; this approach allows exploiting the available Degrees of Freedom (i.e. DoFs) of the robot kinematic chain to achieve the desired end-effector pose; however, if used to operate non-redundant exoskeletons, it does not ensure that anthropomorphic criteria are satisfied in the whole human-robot workspace. This paper proposes a motion planning system, based on Learning by Demonstration, for upper-limb exoskeletons that allow successfully assisting patients during Activities of Daily Living (ADLs) in unstructured environment, while ensuring that anthropomorphic criteria are satisfied in the whole human-robot workspace. The motion planning system combines Learning by Demonstration with the computation of Dynamic Motion Primitives and machine learning techniques to construct task- and patient-specific joint trajectories based on the learnt trajectories. System validation was carried out in simulation and in a real setting with a 4-DoF upper-limb exoskeleton, a 5-DoF wrist-hand exoskeleton and four patients with Limb Girdle Muscular Dystrophy. Validation was addressed to (i) compare the performance of the proposed motion planning with traditional methods; (ii) assess the generalization capabilities of the proposed method with respect to the environment variability. Three ADLs were chosen to validate the system: drinking, pouring and lifting a light sphere. The achieved results showed a 100% success rate in the task fulfillment, with a high level of generalization with respect to the environment variability. Moreover, an anthropomorphic configuration of the exoskeleton is always ensured.

  13. Vegetable behavioral tool demonstrates validity with MyPlate vegetable cups and carotenoid and inflammatory biomarkers

    USDA-ARS?s Scientific Manuscript database

    Young children are not meeting recommendations for vegetable intake. Our objective is to provide evidence of validity and reliability for a pictorial vegetable behavioral assessment for use by federally funded community nutrition programs. Parent/child pairs (n=133) from Head Start and the Special S...

  14. Airborne Shaped Sonic Boom Demonstration Pressure Measurements with Computational Fluid Dynamics Comparisons

    NASA Technical Reports Server (NTRS)

    Haering, Edward A., Jr.; Murray, James E.; Purifoy, Dana D.; Graham, David H.; Meredith, Keith B.; Ashburn, Christopher E.; Stucky, Mark

    2005-01-01

    The Shaped Sonic Boom Demonstration project showed for the first time that by careful design of aircraft contour the resultant sonic boom can maintain a tailored shape, propagating through a real atmosphere down to ground level. In order to assess the propagation characteristics of the shaped sonic boom and to validate computational fluid dynamics codes, airborne measurements were taken of the pressure signatures in the near field by probing with an instrumented F-15B aircraft, and in the far field by overflying an instrumented L-23 sailplane. This paper describes each aircraft and their instrumentation systems, the airdata calibration, analysis of the near- and far-field airborne data, and shows the good to excellent agreement between computational fluid dynamics solutions and flight data. The flights of the Shaped Sonic Boom Demonstration aircraft occurred in two phases. Instrumentation problems were encountered during the first phase, and corrections and improvements were made to the instrumentation system for the second phase, which are documented in the paper. Piloting technique and observations are also given. These airborne measurements of the Shaped Sonic Boom Demonstration aircraft are a unique and important database that will be used to validate design tools for a new generation of quiet supersonic aircraft.

  15. Tested Demonstrations.

    ERIC Educational Resources Information Center

    Gilbert, George L., Ed.

    1985-01-01

    List of materials needed, procedures used, and results obtained are provided for two demonstrations. The first is an inexpensive and quick method for demonstrating column chromatography of plant pigments of spinach extract. The second is a demonstration of cathodic protection by impressed current. (JN)

  16. Validation of the Simple Shoulder Test in a Portuguese-Brazilian Population. Is the Latent Variable Structure and Validation of the Simple Shoulder Test Stable across Cultures?

    PubMed Central

    Neto, Jose Osni Bruggemann; Gesser, Rafael Lehmkuhl; Steglich, Valdir; Bonilauri Ferreira, Ana Paula; Gandhi, Mihir; Vissoci, João Ricardo Nickenig; Pietrobon, Ricardo

    2013-01-01

    Background The validation of widely used scales facilitates the comparison across international patient samples. The objective of this study was to translate, culturally adapt and validate the Simple Shoulder Test into Brazilian Portuguese. Also we test the stability of factor analysis across different cultures. Objective The objective of this study was to translate, culturally adapt and validate the Simple Shoulder Test into Brazilian Portuguese. Also we test the stability of factor analysis across different cultures. Methods The Simple Shoulder Test was translated from English into Brazilian Portuguese, translated back into English, and evaluated for accuracy by an expert committee. It was then administered to 100 patients with shoulder conditions. Psychometric properties were analyzed including factor analysis, internal reliability, test-retest reliability at seven days, and construct validity in relation to the Short Form 36 health survey (SF-36). Results Factor analysis demonstrated a three factor solution. Cronbach’s alpha was 0.82. Test-retest reliability index as measured by intra-class correlation coefficient (ICC) was 0.84. Associations were observed in the hypothesized direction with all subscales of SF-36 questionnaire. Conclusion The Simple Shoulder Test translation and cultural adaptation to Brazilian-Portuguese demonstrated adequate factor structure, internal reliability, and validity, ultimately allowing for its use in the comparison with international patient samples. PMID:23675436

  17. A Gigabit-per-Second Ka-Band Demonstration Using a Reconfigurable FPGA Modulator

    NASA Technical Reports Server (NTRS)

    Lee, Dennis; Gray, Andrew A.; Kang, Edward C.; Tsou, Haiping; Lay, Norman E.; Fong, Wai; Fisher, Dave; Hoy, Scott

    2005-01-01

    Gigabit-per-second communications have been a desired target for future NASA Earth science missions, and for potential manned lunar missions. Frequency bandwidth at S-band and X-band is typically insufficient to support missions at these high data rates. In this paper, we present the results of a 1 Gbps 32-QAM end-to-end experiment at Ka-band using a reconfigurable Field Programmable Gate Array (FPGA) baseband modulator board. Bit error rate measurements of the received signal using a software receiver demonstrate the feasibility of using ultra-high data rates at Ka-band, although results indicate that error correcting coding and/or modulator predistortion must be implemented in addition. Also, results of the demonstration validate the low-cost, MOS-based reconfigurable modulator approach taken to development of a high rate modulator, as opposed to more expensive ASIC or pure analog approaches.

  18. Solar Concentrator Demonstrator for Lunar Regolith Processing

    NASA Technical Reports Server (NTRS)

    Fikes, John C.; Howell, Joe T.; Gerrish, Harold P.; Patrick, Stephen L.

    2008-01-01

    NASA at the Marshall Space Flight Center (MSFC) is building a portable inflatable solar concentrator ground demonstrator for use in testing in-situ resource utilization (ISRU) lunar regolith processing methods. Of primary interest is the production of oxygen as a propellant oxidizer and for life support. There are various processes being proposed for the in-situ reduction of the lunar regolith, the leading processes are hydrogen reduction, carbothermal reduction and vapor phase pyrolysis. The concentrator system being built at MSFC could support demonstrations of all of these processes. The system consists of a light inflatable concentrator that will capture sunlight and focus it onto a receiver inside a vacuum chamber. Inflatable concentrators are good for space based applications due to their low weight and dense packaging at launch. The hexapod design allows the spot size to be increased to reduce the power density if needed for the process being demonstrated. In addition to the hardware development, a comprehensive simulation model is being developed and will be verified and validated using the system hardware. The model will allow for the evaluation of different lunar locations and operational scenarios for the lunar regolith processing with a high confidence in the predicted results.

  19. Cross-validation pitfalls when selecting and assessing regression and classification models.

    PubMed

    Krstajic, Damjan; Buturovic, Ljubomir J; Leahy, David E; Thomas, Simon

    2014-03-29

    We address the problem of selecting and assessing classification and regression models using cross-validation. Current state-of-the-art methods can yield models with high variance, rendering them unsuitable for a number of practical applications including QSAR. In this paper we describe and evaluate best practices which improve reliability and increase confidence in selected models. A key operational component of the proposed methods is cloud computing which enables routine use of previously infeasible approaches. We describe in detail an algorithm for repeated grid-search V-fold cross-validation for parameter tuning in classification and regression, and we define a repeated nested cross-validation algorithm for model assessment. As regards variable selection and parameter tuning we define two algorithms (repeated grid-search cross-validation and double cross-validation), and provide arguments for using the repeated grid-search in the general case. We show results of our algorithms on seven QSAR datasets. The variation of the prediction performance, which is the result of choosing different splits of the dataset in V-fold cross-validation, needs to be taken into account when selecting and assessing classification and regression models. We demonstrate the importance of repeating cross-validation when selecting an optimal model, as well as the importance of repeating nested cross-validation when assessing a prediction error.

  20. Laser Spectroscopy Multi-Gas Monitor: Results of Technology Demonstration on ISS

    NASA Technical Reports Server (NTRS)

    Mudgett, Paul D.; Pilgrim, Jeffrey S.

    2015-01-01

    Tunable diode laser spectroscopy (TDLS) is an up and coming trace and major gas monitoring technology with unmatched selectivity, range and stability. The technology demonstration of the 4 gas Multi-Gas Monitor (MGM), reported at the 2014 ICES conference, operated continuously on the International Space Station (ISS) for nearly a year. The MGM is designed to measure oxygen, carbon dioxide, ammonia and water vapor in ambient cabin air in a low power, relatively compact device. While on board, the MGM experienced a number of challenges, unplanned and planned, including a test of the ammonia channel using a commercial medical ammonia inhalant. Data from the unit was downlinked once per week and compared with other analytical resources on board, notably the Major Constituent Analyzer (MCA), a magnetic sector mass spectrometer. MGM spent the majority of the time installed in the Nanoracks Frame 2 payload facility in front breathing mode (sampling the ambient environment of the Japanese Experiment Module), but was also used to analyze recirculated rack air. The capability of the MGM to be operated in portable mode (via internal rechargeable lithium ion polymer batteries or by plugging into any Express Rack 28VDC connector) was a part of the usability demonstration. Results to date show unprecedented stability and accuracy of the MGM vs. the MCA for oxygen and carbon dioxide. The ammonia challenge (approx. 75 ppm) was successful as well, showing very rapid response time in both directions. Work on an expansion of capability in a next generation MGM has just begun. Combustion products and hydrazine are being added to the measurable target analytes. An 8 to 10 gas monitor (aka Gas Tricorder 1.0) is envisioned for use on ISS, Orion and Exploration missions.

  1. Affordable Flight Demonstration of the GTX Air-Breathing SSTO Vehicle Concept

    NASA Technical Reports Server (NTRS)

    Krivanek, Thomas M.; Roche, Joseph M.; Riehl, John P.; Kosareo, Daniel N.

    2003-01-01

    The rocket based combined cycle (RBCC) powered single-stage-to-orbit (SSTO) reusable launch vehicle has the potential to significantly reduce the total cost per pound for orbital payload missions. To validate overall system performance, a flight demonstration must be performed. This paper presents an overview of the first phase of a flight demonstration program for the GTX SSTO vehicle concept. Phase 1 will validate the propulsion performance of the vehicle configuration over the supersonic and hypersonic air- breathing portions of the trajectory. The focus and goal of Phase 1 is to demonstrate the integration and performance of the propulsion system flowpath with the vehicle aerodynamics over the air-breathing trajectory. This demonstrator vehicle will have dual mode ramjetkcramjets, which include the inlet, combustor, and nozzle with geometrically scaled aerodynamic surface outer mold lines (OML) defining the forebody, boundary layer diverter, wings, and tail. The primary objective of this study is to demon- strate propulsion system performance and operability including the ram to scram transition, as well as to validate vehicle aerodynamics and propulsion airframe integration. To minimize overall risk and develop ment cost the effort will incorporate proven materials, use existing turbomachinery in the propellant delivery systems, launch from an existing unmanned remote launch facility, and use basic vehicle recovery techniques to minimize control and landing requirements. A second phase would demonstrate propulsion performance across all critical portions of a space launch trajectory (lift off through transition to all-rocket) integrated with flight-like vehicle systems.

  2. Validation of the M. D. Anderson Symptom Inventory multiple myeloma module

    PubMed Central

    2013-01-01

    Background The symptom burden associated with multiple myeloma (MM) is often severe. Presently, no instrument comprehensively assesses disease-related and treatment-related symptoms in patients with MM. We sought to validate a module of the M. D. Anderson Symptom Inventory (MDASI) developed specifically for patients with MM (MDASI-MM). Methods The MDASI-MM was developed with clinician input, cognitive debriefing, and literature review, and administered to 132 patients undergoing induction chemotherapy or stem cell transplantation. We demonstrated the MDASI-MM’s reliability (Cronbach α values); criterion validity (item and subscale correlations between the MDASI-MM and the European Organization for Research and Treatment of Cancer Quality of Life Questionnaire (EORTC QLQ-C30) and the EORTC MM module (QLQ-MY20)), and construct validity (differences between groups by performance status). Ratings from transplant patients were examined to demonstrate the MDASI-MM’s sensitivity in detecting the acute worsening of symptoms post-transplantation. Results The MDASI-MM demonstrated excellent correlations with subscales of the 2 EORTC instruments, strong ability to distinguish clinically different patient groups, high sensitivity in detecting change in patients’ performance status, and high reliability. Cognitive debriefing confirmed that the MDASI-MM encompasses the breadth of symptoms relevant to patients with MM. Conclusion The MDASI-MM is a valid, reliable, comprehensive-yet-concise tool that is recommended as a uniform symptom assessment instrument for patients with MM. PMID:23384030

  3. Demonstration Results of Phytoremediation of Explosives-Contaminated Groundwater Using Constructed Wetlands At The Milan Army Ammunition Plant, Milan, Tennessee Volume IV.

    DTIC Science & Technology

    1998-12-01

    1030 1 DEMONSTRATION RESULTS OF PHYTOREMEDIATION OF EXPLOSIVES-CONTAMINATED GROUNDWATER USING CONSTRUCTED WETLANDS AT THE MILAN ARMY...88826V Report No. SFIM-AEC-ET-CR-97059 UTIC QUALITY INSPECTED 4 Demonstration Results of Phytoremediation of Explosives-Contaminated Groundwater...SUBTITLE Demonstration Results of Phytoremediation of Explosives-Contaminated Groundwater Using Constructed Wetlands at the Milan Army Ammunition Plant

  4. How to test validity in orthodontic research: a mixed dentition analysis example.

    PubMed

    Donatelli, Richard E; Lee, Shin-Jae

    2015-02-01

    The data used to test the validity of a prediction method should be different from the data used to generate the prediction model. In this study, we explored whether an independent data set is mandatory for testing the validity of a new prediction method and how validity can be tested without independent new data. Several validation methods were compared in an example using the data from a mixed dentition analysis with a regression model. The validation errors of real mixed dentition analysis data and simulation data were analyzed for increasingly large data sets. The validation results of both the real and the simulation studies demonstrated that the leave-1-out cross-validation method had the smallest errors. The largest errors occurred in the traditional simple validation method. The differences between the validation methods diminished as the sample size increased. The leave-1-out cross-validation method seems to be an optimal validation method for improving the prediction accuracy in a data set with limited sample sizes. Copyright © 2015 American Association of Orthodontists. Published by Elsevier Inc. All rights reserved.

  5. Valid methods: the quality assurance of test method development, validation, approval, and transfer for veterinary testing laboratories.

    PubMed

    Wiegers, Ann L

    2003-07-01

    Third-party accreditation is a valuable tool to demonstrate a laboratory's competence to conduct testing. Accreditation, internationally and in the United States, has been discussed previously. However, accreditation is only I part of establishing data credibility. A validated test method is the first component of a valid measurement system. Validation is defined as confirmation by examination and the provision of objective evidence that the particular requirements for a specific intended use are fulfilled. The international and national standard ISO/IEC 17025 recognizes the importance of validated methods and requires that laboratory-developed methods or methods adopted by the laboratory be appropriate for the intended use. Validated methods are therefore required and their use agreed to by the client (i.e., end users of the test results such as veterinarians, animal health programs, and owners). ISO/IEC 17025 also requires that the introduction of methods developed by the laboratory for its own use be a planned activity conducted by qualified personnel with adequate resources. This article discusses considerations and recommendations for the conduct of veterinary diagnostic test method development, validation, evaluation, approval, and transfer to the user laboratory in the ISO/IEC 17025 environment. These recommendations are based on those of nationally and internationally accepted standards and guidelines, as well as those of reputable and experienced technical bodies. They are also based on the author's experience in the evaluation of method development and transfer projects, validation data, and the implementation of quality management systems in the area of method development.

  6. Coopers Rock Crop Tree Demonstration Area—20-year results

    Treesearch

    Arlyn W. Perkey; Gary W. Miller; David L. Feicht

    2011-01-01

    During the 1988/1989 dormant season, the Coopers Rock Crop Tree Demonstration Area was established in a 55-year-old central Appalachian hardwood forest in north-central West Virginia. After treatment, 89 northern red oak (Quercus rubra L.) and 147 yellow-poplar (Liriodentron tulipifera L.) crop trees were monitored for 20 years....

  7. Development, reliability, and validity of the My Child's Play (MCP) questionnaire.

    PubMed

    Schneider, Eleanor; Rosenblum, Sara

    2014-01-01

    This article describes the development, reliability, and validity of My Child's Play (MCP), a parent questionnaire designed to evaluate the play of children ages 3-9 yr. The first phase of the study determined the questionnaire's content and face validity. Subsequently, the internal reliability consistency and construct and concurrent validity were demonstrated using 334 completed questionnaires. The MCP showed good internal consistency (α = .86). The factor analysis revealed four distinct factors with acceptable levels of internal reliability (Cronbach's αs = .63-.81) and gender- and age-related differences in play characteristics; both findings attest to the tool's construct validity. Significant correlations (r = .33, p < .0001) with the Parent as a Teacher Inventory demonstrate the MCP's concurrent validity. The MCP demonstrated acceptable reliability and validity. It appears to be a promising standardized assessment tool for use in research and practice to promote understanding of a child's play. Copyright © 2014 by the American Occupational Therapy Association, Inc.

  8. Joint Test Protocol for Validation of Alternatives to Aliphatic Isocyanate Polyurethanes

    NASA Technical Reports Server (NTRS)

    Lewis, Pattie

    2005-01-01

    The primary objective of this effort is to demonstrate and validate alternatives to aliphatic isocyanate polyurethanes. Successful completion of this project will result in one or more isocyanate-free coatings qualified for use at AFSPC and NASA installations participating in this project.

  9. Examining construct and predictive validity of the Health-IT Usability Evaluation Scale: confirmatory factor analysis and structural equation modeling results

    PubMed Central

    Yen, Po-Yin; Sousa, Karen H; Bakken, Suzanne

    2014-01-01

    Background In a previous study, we developed the Health Information Technology Usability Evaluation Scale (Health-ITUES), which is designed to support customization at the item level. Such customization matches the specific tasks/expectations of a health IT system while retaining comparability at the construct level, and provides evidence of its factorial validity and internal consistency reliability through exploratory factor analysis. Objective In this study, we advanced the development of Health-ITUES to examine its construct validity and predictive validity. Methods The health IT system studied was a web-based communication system that supported nurse staffing and scheduling. Using Health-ITUES, we conducted a cross-sectional study to evaluate users’ perception toward the web-based communication system after system implementation. We examined Health-ITUES's construct validity through first and second order confirmatory factor analysis (CFA), and its predictive validity via structural equation modeling (SEM). Results The sample comprised 541 staff nurses in two healthcare organizations. The CFA (n=165) showed that a general usability factor accounted for 78.1%, 93.4%, 51.0%, and 39.9% of the explained variance in ‘Quality of Work Life’, ‘Perceived Usefulness’, ‘Perceived Ease of Use’, and ‘User Control’, respectively. The SEM (n=541) supported the predictive validity of Health-ITUES, explaining 64% of the variance in intention for system use. Conclusions The results of CFA and SEM provide additional evidence for the construct and predictive validity of Health-ITUES. The customizability of Health-ITUES has the potential to support comparisons at the construct level, while allowing variation at the item level. We also illustrate application of Health-ITUES across stages of system development. PMID:24567081

  10. The Predictive Validity of the Metropolitan Readiness Tests, 1976 Edition.

    ERIC Educational Resources Information Center

    Nagle, Richard J.

    1979-01-01

    A sample of 176 first-grade children was tested on the Metropolitan Readiness Tests, 1976 Edition (MRT), during the initial month of school and was retested eight months later on the Stanford Achievement Test. Results demonstrated substantial validity of the MRT for predicting first-grade achievement. (Author/CTM)

  11. Evolving Improvements to TRMM Ground Validation Rainfall Estimates

    NASA Technical Reports Server (NTRS)

    Robinson, M.; Kulie, M. S.; Marks, D. A.; Wolff, D. B.; Ferrier, B. S.; Amitai, E.; Silberstein, D. S.; Fisher, B. L.; Wang, J.; Einaudi, Franco (Technical Monitor)

    2000-01-01

    The primary function of the TRMM Ground Validation (GV) Program is to create GV rainfall products that provide basic validation of satellite-derived precipitation measurements for select primary sites. Since the successful 1997 launch of the TRMM satellite, GV rainfall estimates have demonstrated systematic improvements directly related to improved radar and rain gauge data, modified science techniques, and software revisions. Improved rainfall estimates have resulted in higher quality GV rainfall products and subsequently, much improved evaluation products for the satellite-based precipitation estimates from TRMM. This presentation will demonstrate how TRMM GV rainfall products created in a semi-automated, operational environment have evolved and improved through successive generations. Monthly rainfall maps and rainfall accumulation statistics for each primary site will be presented for each stage of GV product development. Contributions from individual product modifications involving radar reflectivity (Ze)-rain rate (R) relationship refinements, improvements in rain gauge bulk-adjustment and data quality control processes, and improved radar and gauge data will be discussed. Finally, it will be demonstrated that as GV rainfall products have improved, rainfall estimation comparisons between GV and satellite have converged, lending confidence to the satellite-derived precipitation measurements from TRMM.

  12. Wallula Basalt Pilot Demonstration Project: Post-injection Results and Conclusions

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    McGrail, Bernard Pete; Schaef, Herbert T.; Spane, Frank A.

    are measurably different from the isotopic content of basalt, injection zone groundwater and for naturally occurring calcite. Final post-injection wireline geophysical logging results also indicate the presence of free-phase CO 2 at the top of the two injection interflow zones, with no vertical migration of CO 2 above the injection horizons. Furthermore, these findings are significant and demonstrate the feasibility of sequestering CO 2 in a basalt formation.« less

  13. Wallula Basalt Pilot Demonstration Project: Post-injection Results and Conclusions

    DOE PAGES

    McGrail, Bernard Pete; Schaef, Herbert T.; Spane, Frank A.; ...

    2017-08-18

    are measurably different from the isotopic content of basalt, injection zone groundwater and for naturally occurring calcite. Final post-injection wireline geophysical logging results also indicate the presence of free-phase CO 2 at the top of the two injection interflow zones, with no vertical migration of CO 2 above the injection horizons. Furthermore, these findings are significant and demonstrate the feasibility of sequestering CO 2 in a basalt formation.« less

  14. Preliminary Validity of the Eyberg Child Behavior Inventory With Filipino Immigrant Parents

    PubMed Central

    Coffey, Dean M.; Javier, Joyce R.; Schrager, Sheree M.

    2016-01-01

    Filipinos are an understudied minority affected by significant behavioral health disparities. We evaluate evidence for the reliability, construct validity, and convergent validity of the Eyberg Child Behavior Inventory (ECBI) in 6- to 12- year old Filipino children (N = 23). ECBI scores demonstrated high internal consistency, supporting a single-factor model (pre-intervention α =.91; post-intervention α =.95). Results document convergent validity with the Child Behavior Checklist Externalizing scale at pretest (r = .54, p < .01) and posttest (r = .71, p < .001). We conclude that the ECBI is a promising tool to measure behavior problems in Filipino children. PMID:27087739

  15. Preliminary Validity of the Eyberg Child Behavior Inventory With Filipino Immigrant Parents.

    PubMed

    Coffey, Dean M; Javier, Joyce R; Schrager, Sheree M

    Filipinos are an understudied minority affected by significant behavioral health disparities. We evaluate evidence for the reliability, construct validity, and convergent validity of the Eyberg Child Behavior Inventory (ECBI) in 6- to 12- year old Filipino children ( N = 23). ECBI scores demonstrated high internal consistency, supporting a single-factor model (pre-intervention α =.91; post-intervention α =.95). Results document convergent validity with the Child Behavior Checklist Externalizing scale at pretest ( r = .54, p < .01) and posttest ( r = .71, p < .001). We conclude that the ECBI is a promising tool to measure behavior problems in Filipino children.

  16. Development and validation of a knowledge test for health professionals regarding lifestyle modification.

    PubMed

    Talip, Whadi-ah; Steyn, Nelia P; Visser, Marianne; Charlton, Karen E; Temple, Norman

    2003-09-01

    We wanted to develop and validate a test that assesses the knowledge and practices of health professionals (HPs) with regard to the role of nutrition, physical activity, and smoking cessation (lifestyle modification) in chronic diseases of lifestyle. A descriptive cross-sectional validation study was carried out. The validation design consisted of two phases, namely 1) test planning and development and 2) test evaluation. The study sample consisted of five groups of HPs: dietitians, dietetic interns, general practitioners, medical students, and nurses. The overall response rate was 58%, resulting in a sample size of 186 participants. A test was designed to evaluate the knowledge and practices of HPs. The test was first evaluated by an expert group to ensure content, construct, and face validity. Thereafter, the questionnaire was tested on five groups of HPs to test for criterion validity. Internal consistency was evaluated by Cronbach's alpha. An expert panel ensured content, construct, and face validity of the test. Groups with the most training and exposure to nutrition (dietitians and dietetic interns) had the highest group mean score, ranging from 61% to 88%, whereas those with limited nutrition training (general practitioners, medical students, and nurses) had significantly lower scores, ranging from 26% to 80%. This result demonstrated criterion validity. Internal consistency of the overall test demonstrated a Cronbach's alpha of 0.99. Most HPs identified the mass media as their main source of information on lifestyle modification. These HPs also identified lack of time, lack of patient compliance, and lack of knowledge as barriers that prevent them from providing counseling on lifestyle modification. The results of this study showed that this test instrument identifies groups of health professionals with adequate training (knowledge) in lifestyle modification and those who require further training (knowledge).

  17. High Reliability Engine Control Demonstrated for Aircraft Engines

    NASA Technical Reports Server (NTRS)

    Guo, Ten-Huei

    1999-01-01

    For a dual redundant-control system, which is typical for short-haul aircraft, if a failure is detected in a control sensor, the engine control is transferred to a safety mode and an advisory is issued for immediate maintenance action to replace the failed sensor. The safety mode typically results in severely degraded engine performance. The goal of the High Reliability Engine Control (HREC) program was to demonstrate that the neural-network-based sensor validation technology can safely operate an engine by using the nominal closed-loop control during and after sensor failures. With this technology, engine performance could be maintained, and the sensor could be replaced as a conveniently scheduled maintenance action.

  18. A Possible Tool for Checking Errors in the INAA Results, Based on Neutron Data and Method Validation

    NASA Astrophysics Data System (ADS)

    Cincu, Em.; Grigore, Ioana Manea; Barbos, D.; Cazan, I. L.; Manu, V.

    2008-08-01

    This work presents preliminary results of a new type of possible application in the INAA experiments of elemental analysis, useful to check errors occurred during investigation of unknown samples; it relies on the INAA method validation experiments and accuracy of the neutron data from the literature. The paper comprises 2 sections, the first one presents—in short—the steps of the experimental tests carried out for INAA method validation and for establishing the `ACTIVA-N' laboratory performance, which is-at the same time-an illustration of the laboratory evolution on the way to get performance. Section 2 presents our recent INAA results on CRMs, of which interpretation opens discussions about the usefulness of using a tool for checking possible errors, different from the usual statistical procedures. The questionable aspects and the requirements to develop a practical checking tool are discussed.

  19. ASTER Global Digital Elevation Model Version 2 - summary of validation results

    USGS Publications Warehouse

    Tachikawa, Tetushi; Kaku, Manabu; Iwasaki, Akira; Gesch, Dean B.; Oimoen, Michael J.; Zhang, Z.; Danielson, Jeffrey J.; Krieger, Tabatha; Curtis, Bill; Haase, Jeff; Abrams, Michael; Carabajal, C.; Meyer, Dave

    2011-01-01

    Based on these findings, the GDEM validation team recommends the release of the GDEM2 to the public, acknowledging that, while vastly improved, some artifacts still exist which could affect its utility in certain applications.

  20. Tested Demonstrations.

    ERIC Educational Resources Information Center

    Gilbert, George L., Ed.

    1989-01-01

    Presented are two demonstrations including a variation of the iodine clock reaction, and a simple demonstration of refractive index. The materials, procedures, and a discussion of probable results are given for each. (CW)

  1. Learning by Demonstration for Motion Planning of Upper-Limb Exoskeletons

    PubMed Central

    Lauretti, Clemente; Cordella, Francesca; Ciancio, Anna Lisa; Trigili, Emilio; Catalan, Jose Maria; Badesa, Francisco Javier; Crea, Simona; Pagliara, Silvio Marcello; Sterzi, Silvia; Vitiello, Nicola; Garcia Aracil, Nicolas; Zollo, Loredana

    2018-01-01

    The reference joint position of upper-limb exoskeletons is typically obtained by means of Cartesian motion planners and inverse kinematics algorithms with the inverse Jacobian; this approach allows exploiting the available Degrees of Freedom (i.e. DoFs) of the robot kinematic chain to achieve the desired end-effector pose; however, if used to operate non-redundant exoskeletons, it does not ensure that anthropomorphic criteria are satisfied in the whole human-robot workspace. This paper proposes a motion planning system, based on Learning by Demonstration, for upper-limb exoskeletons that allow successfully assisting patients during Activities of Daily Living (ADLs) in unstructured environment, while ensuring that anthropomorphic criteria are satisfied in the whole human-robot workspace. The motion planning system combines Learning by Demonstration with the computation of Dynamic Motion Primitives and machine learning techniques to construct task- and patient-specific joint trajectories based on the learnt trajectories. System validation was carried out in simulation and in a real setting with a 4-DoF upper-limb exoskeleton, a 5-DoF wrist-hand exoskeleton and four patients with Limb Girdle Muscular Dystrophy. Validation was addressed to (i) compare the performance of the proposed motion planning with traditional methods; (ii) assess the generalization capabilities of the proposed method with respect to the environment variability. Three ADLs were chosen to validate the system: drinking, pouring and lifting a light sphere. The achieved results showed a 100% success rate in the task fulfillment, with a high level of generalization with respect to the environment variability. Moreover, an anthropomorphic configuration of the exoskeleton is always ensured. PMID:29527161

  2. 76 FR 81991 - National Spectrum Sharing Research Experimentation, Validation, Verification, Demonstration and...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-12-29

    ... non-federal community, including the academic, commercial, and public safety sectors, to implement a..., Verification, Demonstration and Trials: Technical Workshop II on Coordinating Federal Government/Private Sector Spectrum Innovation Testing Needs AGENCY: The National Coordination Office (NCO) for Networking and...

  3. Validation of Yoon's Critical Thinking Disposition Instrument.

    PubMed

    Shin, Hyunsook; Park, Chang Gi; Kim, Hyojin

    2015-12-01

    The lack of reliable and valid evaluation tools targeting Korean nursing students' critical thinking (CT) abilities has been reported as one of the barriers to instructing and evaluating students in undergraduate programs. Yoon's Critical Thinking Disposition (YCTD) instrument was developed for Korean nursing students, but few studies have assessed its validity. This study aimed to validate the YCTD. Specifically, the YCTD was assessed to identify its cross-sectional and longitudinal measurement invariance. This was a validation study in which a cross-sectional and longitudinal (prenursing and postnursing practicum) survey was used to validate the YCTD using 345 nursing students at three universities in Seoul, Korea. The participants' CT abilities were assessed using the YCTD before and after completing an established pediatric nursing practicum. The validity of the YCTD was estimated and then group invariance test using multigroup confirmatory factor analysis was performed to confirm the measurement compatibility of multigroups. A test of the seven-factor model showed that the YCTD demonstrated good construct validity. Multigroup confirmatory factor analysis findings for the measurement invariance suggested that this model structure demonstrated strong invariance between groups (i.e., configural, factor loading, and intercept combined) but weak invariance within a group (i.e., configural and factor loading combined). In general, traditional methods for assessing instrument validity have been less than thorough. In this study, multigroup confirmatory factor analysis using cross-sectional and longitudinal measurement data allowed validation of the YCTD. This study concluded that the YCTD can be used for evaluating Korean nursing students' CT abilities. Copyright © 2015. Published by Elsevier B.V.

  4. Environmental education curriculum evaluation questionnaire: A reliability and validity study

    NASA Astrophysics Data System (ADS)

    Minner, Daphne Diane

    The intention of this research project was to bridge the gap between social science research and application to the environmental domain through the development of a theoretically derived instrument designed to give educators a template by which to evaluate environmental education curricula. The theoretical base for instrument development was provided by several developmental theories such as Piaget's theory of cognitive development, Developmental Systems Theory, Life-span Perspective, as well as curriculum research within the area of environmental education. This theoretical base fueled the generation of a list of components which were then translated into a questionnaire with specific questions relevant to the environmental education domain. The specific research question for this project is: Can a valid assessment instrument based largely on human development and education theory be developed that reliably discriminates high, moderate, and low quality in environmental education curricula? The types of analyses conducted to answer this question were interrater reliability (percent agreement, Cohen's Kappa coefficient, Pearson's Product-Moment correlation coefficient), test-retest reliability (percent agreement, correlation), and criterion-related validity (correlation). Face validity and content validity were also assessed through thorough reviews. Overall results indicate that 29% of the questions on the questionnaire demonstrated a high level of interrater reliability and 43% of the questions demonstrated a moderate level of interrater reliability. Seventy-one percent of the questions demonstrated a high test-retest reliability and 5% a moderate level. Fifty-five percent of the questions on the questionnaire were reliable (high or moderate) both across time and raters. Only eight questions (8%) did not show either interrater or test-retest reliability. The global overall rating of high, medium, or low quality was reliable across both coders and time, indicating

  5. Using the web to validate document recognition results: experiments with business cards

    NASA Astrophysics Data System (ADS)

    Oertel, Clemens; O'Shea, Shauna; Bodnar, Adam; Blostein, Dorothea

    2004-12-01

    The World Wide Web is a vast information resource which can be useful for validating the results produced by document recognizers. Three computational steps are involved, all of them challenging: (1) use the recognition results in a Web search to retrieve Web pages that contain information similar to that in the document, (2) identify the relevant portions of the retrieved Web pages, and (3) analyze these relevant portions to determine what corrections (if any) should be made to the recognition result. We have conducted exploratory implementations of steps (1) and (2) in the business-card domain: we use fields of the business card to retrieve Web pages and identify the most relevant portions of those Web pages. In some cases, this information appears suitable for correcting OCR errors in the business card fields. In other cases, the approach fails due to stale information: when business cards are several years old and the business-card holder has changed jobs, then websites (such as the home page or company website) no longer contain information matching that on the business card. Our exploratory results indicate that in some domains it may be possible to develop effective means of querying the Web with recognition results, and to use this information to correct the recognition results and/or detect that the information is stale.

  6. Using the web to validate document recognition results: experiments with business cards

    NASA Astrophysics Data System (ADS)

    Oertel, Clemens; O'Shea, Shauna; Bodnar, Adam; Blostein, Dorothea

    2005-01-01

    The World Wide Web is a vast information resource which can be useful for validating the results produced by document recognizers. Three computational steps are involved, all of them challenging: (1) use the recognition results in a Web search to retrieve Web pages that contain information similar to that in the document, (2) identify the relevant portions of the retrieved Web pages, and (3) analyze these relevant portions to determine what corrections (if any) should be made to the recognition result. We have conducted exploratory implementations of steps (1) and (2) in the business-card domain: we use fields of the business card to retrieve Web pages and identify the most relevant portions of those Web pages. In some cases, this information appears suitable for correcting OCR errors in the business card fields. In other cases, the approach fails due to stale information: when business cards are several years old and the business-card holder has changed jobs, then websites (such as the home page or company website) no longer contain information matching that on the business card. Our exploratory results indicate that in some domains it may be possible to develop effective means of querying the Web with recognition results, and to use this information to correct the recognition results and/or detect that the information is stale.

  7. Method validation for chemical composition determination by electron microprobe with wavelength dispersive spectrometer

    NASA Astrophysics Data System (ADS)

    Herrera-Basurto, R.; Mercader-Trejo, F.; Muñoz-Madrigal, N.; Juárez-García, J. M.; Rodriguez-López, A.; Manzano-Ramírez, A.

    2016-07-01

    The main goal of method validation is to demonstrate that the method is suitable for its intended purpose. One of the advantages of analytical method validation is translated into a level of confidence about the measurement results reported to satisfy a specific objective. Elemental composition determination by wavelength dispersive spectrometer (WDS) microanalysis has been used over extremely wide areas, mainly in the field of materials science, impurity determinations in geological, biological and food samples. However, little information is reported about the validation of the applied methods. Herein, results of the in-house method validation for elemental composition determination by WDS are shown. SRM 482, a binary alloy Cu-Au of different compositions, was used during the validation protocol following the recommendations for method validation proposed by Eurachem. This paper can be taken as a reference for the evaluation of the validation parameters more frequently requested to get the accreditation under the requirements of the ISO/IEC 17025 standard: selectivity, limit of detection, linear interval, sensitivity, precision, trueness and uncertainty. A model for uncertainty estimation was proposed including systematic and random errors. In addition, parameters evaluated during the validation process were also considered as part of the uncertainty model.

  8. Guidelines To Validate Control of Cross-Contamination during Washing of Fresh-Cut Leafy Vegetables.

    PubMed

    Gombas, D; Luo, Y; Brennan, J; Shergill, G; Petran, R; Walsh, R; Hau, H; Khurana, K; Zomorodi, B; Rosen, J; Varley, R; Deng, K

    2017-02-01

    The U.S. Food and Drug Administration requires food processors to implement and validate processes that will result in significantly minimizing or preventing the occurrence of hazards that are reasonably foreseeable in food production. During production of fresh-cut leafy vegetables, microbial contamination that may be present on the product can spread throughout the production batch when the product is washed, thus increasing the risk of illnesses. The use of antimicrobials in the wash water is a critical step in preventing such water-mediated cross-contamination; however, many factors can affect antimicrobial efficacy in the production of fresh-cut leafy vegetables, and the procedures for validating this key preventive control have not been articulated. Producers may consider three options for validating antimicrobial washing as a preventive control for cross-contamination. Option 1 involves the use of a surrogate for the microbial hazard and the demonstration that cross-contamination is prevented by the antimicrobial wash. Option 2 involves the use of antimicrobial sensors and the demonstration that a critical antimicrobial level is maintained during worst-case operating conditions. Option 3 validates the placement of the sensors in the processing equipment with the demonstration that a critical antimicrobial level is maintained at all locations, regardless of operating conditions. These validation options developed for fresh-cut leafy vegetables may serve as examples for validating processes that prevent cross-contamination during washing of other fresh produce commodities.

  9. Validation of the Vanderbilt Holistic Face Processing Test.

    PubMed

    Wang, Chao-Chih; Ross, David A; Gauthier, Isabel; Richler, Jennifer J

    2016-01-01

    The Vanderbilt Holistic Face Processing Test (VHPT-F) is a new measure of holistic face processing with better psychometric properties relative to prior measures developed for group studies (Richler et al., 2014). In fields where psychologists study individual differences, validation studies are commonplace and the concurrent validity of a new measure is established by comparing it to an older measure with established validity. We follow this approach and test whether the VHPT-F measures the same construct as the composite task, which is group-based measure at the center of the large literature on holistic face processing. In Experiment 1, we found a significant correlation between holistic processing measured in the VHPT-F and the composite task. Although this correlation was small, it was comparable to the correlation between holistic processing measured in the composite task with the same faces, but different target parts (top or bottom), which represents a reasonable upper limit for correlations between the composite task and another measure of holistic processing. These results confirm the validity of the VHPT-F by demonstrating shared variance with another measure of holistic processing based on the same operational definition. These results were replicated in Experiment 2, but only when the demographic profile of our sample matched that of Experiment 1.

  10. Validation of the Vanderbilt Holistic Face Processing Test

    PubMed Central

    Wang, Chao-Chih; Ross, David A.; Gauthier, Isabel; Richler, Jennifer J.

    2016-01-01

    The Vanderbilt Holistic Face Processing Test (VHPT-F) is a new measure of holistic face processing with better psychometric properties relative to prior measures developed for group studies (Richler et al., 2014). In fields where psychologists study individual differences, validation studies are commonplace and the concurrent validity of a new measure is established by comparing it to an older measure with established validity. We follow this approach and test whether the VHPT-F measures the same construct as the composite task, which is group-based measure at the center of the large literature on holistic face processing. In Experiment 1, we found a significant correlation between holistic processing measured in the VHPT-F and the composite task. Although this correlation was small, it was comparable to the correlation between holistic processing measured in the composite task with the same faces, but different target parts (top or bottom), which represents a reasonable upper limit for correlations between the composite task and another measure of holistic processing. These results confirm the validity of the VHPT-F by demonstrating shared variance with another measure of holistic processing based on the same operational definition. These results were replicated in Experiment 2, but only when the demographic profile of our sample matched that of Experiment 1. PMID:27933014

  11. Comprehensive Calibration and Validation Site for Information Remote Sensing

    NASA Astrophysics Data System (ADS)

    Li, C. R.; Tang, L. L.; Ma, L. L.; Zhou, Y. S.; Gao, C. X.; Wang, N.; Li, X. H.; Wang, X. H.; Zhu, X. H.

    2015-04-01

    As a naturally part of information technology, Remote Sensing (RS) is strongly required to provide very precise and accurate information product to serve industry, academy and the public at this information economic era. To meet the needs of high quality RS product, building a fully functional and advanced calibration system, including measuring instruments, measuring approaches and target site become extremely important. Supported by MOST of China via national plan, great progress has been made to construct a comprehensive calibration and validation (Cal&Val) site, which integrates most functions of RS sensor aviation testing, EO satellite on-orbit caration and performance assessment and RS product validation at this site located in Baotou, 600km west of Beijing. The site is equipped with various artificial standard targets, including portable and permanent targets, which supports for long-term calibration and validation. A number of fine-designed ground measuring instruments and airborne standard sensors are developed for realizing high-accuracy stepwise validation, an approach in avoiding or reducing uncertainties caused from nonsynchronized measurement. As part of contribution to worldwide Cal&Val study coordinated by CEOS-WGCV, Baotou site is offering its support to Radiometric Calibration Network of Automated Instruments (RadCalNet), with an aim of providing demonstrated global standard automated radiometric calibration service in cooperation with ESA, NASA, CNES and NPL. Furthermore, several Cal&Val campaigns have been performed during the past years to calibrate and validate the spaceborne/airborne optical and SAR sensors, and the results of some typical demonstration are discussed in this study.

  12. Integrated propulsion technology demonstrator. Program plan

    NASA Technical Reports Server (NTRS)

    1994-01-01

    NASA and Rockwell have embarked on a cooperative agreement to define, develop, fabricate, and operate an integrated propulsion technology demonstrator (IPTD) for the purpose of validating design, process, and technology improvements of launch vehicle propulsion systems. This program, a result of NRA8-11, Task Area 1 A, is jointly funded by both NASA and Rockwell and is sponsored by the Reusable Launch Vehicle office at NASA Marshall Space flight Center. This program plan provides to the joint NASA/Rockwell integrated propulsion technology demonstrator (IPTD) team a description of the activities within tasks / sub tasks and associated schedules required to successfully achieve program objectives. This document also defines the cost elements and manpower allocations for each sub task for purpose of program control. This plan is updated periodically by developing greater depth of direction for outyear tasks as the program matures. Updating is accomplished by adding revisions to existing pages or attaching page revisions to this plan. In either case, revisions will be identified by appropriate highlighting of the change, or specifying a revision page through the use of footnotes on the bottom right of each change page. Authorization for the change is provided by the principal investigators to maintain control of this program plan document and IPTD program activities.

  13. An empirical assessment of validation practices for molecular classifiers

    PubMed Central

    Castaldi, Peter J.; Dahabreh, Issa J.

    2011-01-01

    Proposed molecular classifiers may be overfit to idiosyncrasies of noisy genomic and proteomic data. Cross-validation methods are often used to obtain estimates of classification accuracy, but both simulations and case studies suggest that, when inappropriate methods are used, bias may ensue. Bias can be bypassed and generalizability can be tested by external (independent) validation. We evaluated 35 studies that have reported on external validation of a molecular classifier. We extracted information on study design and methodological features, and compared the performance of molecular classifiers in internal cross-validation versus external validation for 28 studies where both had been performed. We demonstrate that the majority of studies pursued cross-validation practices that are likely to overestimate classifier performance. Most studies were markedly underpowered to detect a 20% decrease in sensitivity or specificity between internal cross-validation and external validation [median power was 36% (IQR, 21–61%) and 29% (IQR, 15–65%), respectively]. The median reported classification performance for sensitivity and specificity was 94% and 98%, respectively, in cross-validation and 88% and 81% for independent validation. The relative diagnostic odds ratio was 3.26 (95% CI 2.04–5.21) for cross-validation versus independent validation. Finally, we reviewed all studies (n = 758) which cited those in our study sample, and identified only one instance of additional subsequent independent validation of these classifiers. In conclusion, these results document that many cross-validation practices employed in the literature are potentially biased and genuine progress in this field will require adoption of routine external validation of molecular classifiers, preferably in much larger studies than in current practice. PMID:21300697

  14. A Comprehensive Validation Methodology for Sparse Experimental Data

    NASA Technical Reports Server (NTRS)

    Norman, Ryan B.; Blattnig, Steve R.

    2010-01-01

    A comprehensive program of verification and validation has been undertaken to assess the applicability of models to space radiation shielding applications and to track progress as models are developed over time. The models are placed under configuration control, and automated validation tests are used so that comparisons can readily be made as models are improved. Though direct comparisons between theoretical results and experimental data are desired for validation purposes, such comparisons are not always possible due to lack of data. In this work, two uncertainty metrics are introduced that are suitable for validating theoretical models against sparse experimental databases. The nuclear physics models, NUCFRG2 and QMSFRG, are compared to an experimental database consisting of over 3600 experimental cross sections to demonstrate the applicability of the metrics. A cumulative uncertainty metric is applied to the question of overall model accuracy, while a metric based on the median uncertainty is used to analyze the models from the perspective of model development by analyzing subsets of the model parameter space.

  15. Effectively Coping With Task Stress: A Study of the Validity of the Trait Emotional Intelligence Questionnaire-Short Form (TEIQue-SF).

    PubMed

    O'Connor, Peter; Nguyen, Jessica; Anglim, Jeromy

    2017-01-01

    In this study, we investigated the validity of the Trait Emotional Intelligence Questionnaire-Short Form (TEIQue-SF; Petrides, 2009) in the context of task-induced stress. We used a total sample of 225 volunteers to investigate (a) the incremental validity of the TEIQue-SF over other predictors of coping with task-induced stress, and (b) the construct validity of the TEIQue-SF by examining the mechanisms via which scores from the TEIQue-SF predict coping outcomes. Results demonstrated that the TEIQue-SF possessed incremental validity over the Big Five personality traits in the prediction of emotion-focused coping. Results also provided support for the construct validity of the TEIQue-SF by demonstrating that this measure predicted adaptive coping via emotion-focused channels. Specifically, results showed that, following a task stressor, the TEIQue-SF predicted low negative affect and high task performance via high levels of emotion-focused coping. Consistent with the purported theoretical nature of the trait emotional intelligence (EI) construct, trait EI as assessed by the TEIQue-SF primarily enhances affect and performance in stressful situations by regulating negative emotions.

  16. Selecting the "Best" Factor Structure and Moving Measurement Validation Forward: An Illustration.

    PubMed

    Schmitt, Thomas A; Sass, Daniel A; Chappelle, Wayne; Thompson, William

    2018-04-09

    Despite the broad literature base on factor analysis best practices, research seeking to evaluate a measure's psychometric properties frequently fails to consider or follow these recommendations. This leads to incorrect factor structures, numerous and often overly complex competing factor models and, perhaps most harmful, biased model results. Our goal is to demonstrate a practical and actionable process for factor analysis through (a) an overview of six statistical and psychometric issues and approaches to be aware of, investigate, and report when engaging in factor structure validation, along with a flowchart for recommended procedures to understand latent factor structures; (b) demonstrating these issues to provide a summary of the updated Posttraumatic Stress Disorder Checklist (PCL-5) factor models and a rationale for validation; and (c) conducting a comprehensive statistical and psychometric validation of the PCL-5 factor structure to demonstrate all the issues we described earlier. Considering previous research, the PCL-5 was evaluated using a sample of 1,403 U.S. Air Force remotely piloted aircraft operators with high levels of battlefield exposure. Previously proposed PCL-5 factor structures were not supported by the data, but instead a bifactor model is arguably more statistically appropriate.

  17. Initial Validation and Results of Geoscience Laser Altimeter System Optical Properties Retrievals

    NASA Technical Reports Server (NTRS)

    Hlavka, Dennis L.; Hart, W. D.; Pal, S. P.; McGill, M.; Spinhirne, J. D.

    2004-01-01

    Verification of Geoscience Laser Altimeter System (GLAS) optical retrievals is . problematic in that passage over ground sites is both instantaneous and sparse plus space-borne passive sensors such as MODIS are too frequently out of sync with the GLAS position. In October 2003, the GLAS Validation Experiment was executed from NASA Dryden Research Center, California to greatly increase validation possibilities. The high-altitude NASA ER-2 aircraft and onboard instrumentation of Cloud Physics Lidar (CPL), MODIS Airborne Simulator (MAS), and/or MODIS/ASTER Airborne Simulator (MASTER) under-flew seven orbit tracks of GLAS for cirrus, smoke, and urban pollution optical properties inter-comparisons. These highly calibrated suite of instruments are the best data set yet to validate GLAS atmospheric parameters. In this presentation, we will focus on the inter-comparison with GLAS and CPL and draw preliminary conclusions about the accuracies of the GLAS 532nm retrievals of optical depth, extinction, backscatter cross section, and calculated extinction-to-backscatter ratio. Comparisons to an AERONET/MPL ground-based site at Monterey, California will be attempted. Examples of GLAS operational optical data products will be shown.

  18. MRI-based modeling for radiocarpal joint mechanics: validation criteria and results for four specimen-specific models.

    PubMed

    Fischer, Kenneth J; Johnson, Joshua E; Waller, Alexander J; McIff, Terence E; Toby, E Bruce; Bilgen, Mehmet

    2011-10-01

    The objective of this study was to validate the MRI-based joint contact modeling methodology in the radiocarpal joints by comparison of model results with invasive specimen-specific radiocarpal contact measurements from four cadaver experiments. We used a single validation criterion for multiple outcome measures to characterize the utility and overall validity of the modeling approach. For each experiment, a Pressurex film and a Tekscan sensor were sequentially placed into the radiocarpal joints during simulated grasp. Computer models were constructed based on MRI visualization of the cadaver specimens without load. Images were also acquired during the loaded configuration used with the direct experimental measurements. Geometric surface models of the radius, scaphoid and lunate (including cartilage) were constructed from the images acquired without the load. The carpal bone motions from the unloaded state to the loaded state were determined using a series of 3D image registrations. Cartilage thickness was assumed uniform at 1.0 mm with an effective compressive modulus of 4 MPa. Validation was based on experimental versus model contact area, contact force, average contact pressure and peak contact pressure for the radioscaphoid and radiolunate articulations. Contact area was also measured directly from images acquired under load and compared to the experimental and model data. Qualitatively, there was good correspondence between the MRI-based model data and experimental data, with consistent relative size, shape and location of radioscaphoid and radiolunate contact regions. Quantitative data from the model generally compared well with the experimental data for all specimens. Contact area from the MRI-based model was very similar to the contact area measured directly from the images. For all outcome measures except average and peak pressures, at least two specimen models met the validation criteria with respect to experimental measurements for both articulations

  19. Validity of Computer Adaptive Tests of Daily Routines for Youth with Spinal Cord Injury

    PubMed Central

    Haley, Stephen M.

    2013-01-01

    Objective: To evaluate the accuracy of computer adaptive tests (CATs) of daily routines for child- and parent-reported outcomes following pediatric spinal cord injury (SCI) and to evaluate the validity of the scales. Methods: One hundred ninety-six daily routine items were administered to 381 youths and 322 parents. Pearson correlations, intraclass correlation coefficients (ICC), and 95% confidence intervals (CI) were calculated to evaluate the accuracy of simulated 5-item, 10-item, and 15-item CATs against the full-item banks and to evaluate concurrent validity. Independent samples t tests and analysis of variance were used to evaluate the ability of the daily routine scales to discriminate between children with tetraplegia and paraplegia and among 5 motor groups. Results: ICC and 95% CI demonstrated that simulated 5-, 10-, and 15-item CATs accurately represented the full-item banks for both child- and parent-report scales. The daily routine scales demonstrated discriminative validity, except between 2 motor groups of children with paraplegia. Concurrent validity of the daily routine scales was demonstrated through significant relationships with the FIM scores. Conclusion: Child- and parent-reported outcomes of daily routines can be obtained using CATs with the same relative precision of a full-item bank. Five-item, 10-item, and 15-item CATs have discriminative and concurrent validity. PMID:23671380

  20. Diagnostic value of blood-derived microRNAs for schizophrenia: results of a meta-analysis and validation.

    PubMed

    Liu, Sha; Zhang, Fuquan; Wang, Xijin; Shugart, Yin Yao; Zhao, Yingying; Li, Xinrong; Liu, Zhifen; Sun, Ning; Yang, Chunxia; Zhang, Kerang; Yue, Weihua; Yu, Xin; Xu, Yong

    2017-11-10

    There is an increasing interest in searching biomarkers for schizophrenia (SZ) diagnosis, which overcomes the drawbacks inherent with the subjective diagnostic methods. MicroRNA (miRNA) fingerprints have been explored for disease diagnosis. We performed a meta-analysis to examine miRNA diagnostic value for SZ and further validated the meta-analysis results. Using following terms: schizophrenia/SZ, microRNA/miRNA, diagnosis, sensitivity and specificity, we searched databases restricted to English language and reviewed all articles published from January 1990 to October 2016. All extracted data were statistically analyzed and the results were further validated with peripheral blood mononuclear cells (PBMNCs) isolated from patients and healthy controls using RT-qPCR and receiver operating characteristic (ROC) analysis. A total of 6 studies involving 330 patients and 202 healthy controls were included for meta-analysis. The pooled sensitivity, specificity and diagnostic odds ratio were 0.81 (95% CI: 0.75-0.86), 0.81 (95% CI: 0.72-0.88) and 18 (95% CI: 9-34), respectively; the positive and negative likelihood ratio was 4.3 and 0.24 respectively; the area under the curve in summary ROC was 0.87 (95% CI: 0.84-0.90). Validation revealed that miR-181b-5p, miR-21-5p, miR-195-5p, miR-137, miR-346 and miR-34a-5p in PBMNCs had high diagnostic sensitivity and specificity in the context of schizophrenia. In conclusion, blood-derived miRNAs might be promising biomarkers for SZ diagnosis.

  1. Preliminary results of the Geoid Slope Validation Survey 2014 in Iowa

    NASA Astrophysics Data System (ADS)

    Wang, Y. M.; Becker, C.; Breidenbach, S.; Geoghegan, C.; Martin, D.; Winester, D.; Hanson, T.; Mader, G. L.; Eckl, M. C.

    2014-12-01

    The National Geodetic Survey conducted a second Geoid Slope Validation Survey in the summer of 2014 (GSVS14). The survey took place in Iowa along U.S Route 30. The survey line is approximately 200 miles long (325 km), extending from Denison, IA to Cedar Rapids, IA. There are over 200 official survey bench marks. A leveling survey was performed, conforming to 1st order, class II specifications. A GPS survey was performed using 24 to 48 hour occupations. Absolute gravity, relative gravity, and gravity gradient measurements were also collected during the survey. In addition, deflections of the vertical were acquired at 200 eccentric survey benchmarks using the Compact Digital Astrometric Camera (CODIAC) camera. This paper presents the preliminary results of the survey, including the accuracy analysis of the leveling data, GPS ellipsoidal heights, and the deflections of the vertical which serves as an independent data set in addition to the GPS/leveling implied geoid heights.

  2. Predictive validity of cannabis consumption measures: Results from a national longitudinal study.

    PubMed

    Buu, Anne; Hu, Yi-Han; Pampati, Sanjana; Arterberry, Brooke J; Lin, Hsien-Chang

    2017-10-01

    Validating the utility of cannabis consumption measures for predicting later cannabis related symptomatology or progression to cannabis use disorder (CUD) is crucial for prevention and intervention work that may use consumption measures for quick screening. This study examined whether cannabis use quantity and frequency predicted CUD symptom counts, progression to onset of CUD, and persistence of CUD. Data from the National Epidemiologic Survey on Alcohol and Related Conditions (NESARC) at Wave 1 (2001-2002) and Wave 2 (2004-2005) were used to identify three risk samples: (1) current cannabis users at Wave 1 who were at risk for having CUD symptoms at Wave 2; (2) current users without lifetime CUD who were at risk for incident CUD; and (3) current users with past-year CUD who were at risk for persistent CUD. Logistic regression and zero-inflated Poisson models were used to examine the longitudinal effect of cannabis consumption on CUD outcomes. Higher frequency of cannabis use predicted lower likelihood of being symptom-free but it did not predict the severity of CUD symptomatology. Higher frequency of cannabis use also predicted higher likelihood of progression to onset of CUD and persistence of CUD. Cannabis use quantity, however, did not predict any of the developmental stages of CUD symptomatology examined in this study. This study has provided a new piece of evidence to support the predictive validity of cannabis use frequency based on national longitudinal data. The result supports the common practice of including frequency items in cannabis screening tools. Copyright © 2017 Elsevier Ltd. All rights reserved.

  3. The earth radiation budget experiment: Early validation results

    NASA Astrophysics Data System (ADS)

    Smith, G. Louis; Barkstrom, Bruce R.; Harrison, Edwin F.

    The Earth Radiation Budget Experiment (ERBE) consists of radiometers on a dedicated spacecraft in a 57° inclination orbit, which has a precessional period of 2 months, and on two NOAA operational meteorological spacecraft in near polar orbits. The radiometers include scanning narrow field-of-view (FOV) and nadir-looking wide and medium FOV radiometers covering the ranges 0.2 to 5 μm and 5 to 50 μm and a solar monitoring channel. This paper describes the validation procedures and preliminary results. Each of the radiometer channels underwent extensive ground calibration, and the instrument packages include in-flight calibration facilities which, to date, show negligible changes of the instruments in orbit, except for gradual degradation of the suprasil dome of the shortwave wide FOV (about 4% per year). Measurements of the solar constant by the solar monitors, wide FOV, and medium FOV radiometers of two spacecraft agree to a fraction of a percent. Intercomparisons of the wide and medium FOV radiometers with the scanning radiometers show agreement of 1 to 4%. The multiple ERBE satellites are acquiring the first global measurements of regional scale diurnal variations in the Earth's radiation budget. These diurnal variations are verified by comparison with high temporal resolution geostationary satellite data. Other principal investigators of the ERBE Science Team are: R. Cess, SUNY, Stoneybrook; J. Coakley, NCAR; C. Duncan, M. King and A Mecherikunnel, Goddard Space Flight Center, NASA; A. Gruber and A.J. Miller, NOAA; D. Hartmann, U. Washington; F.B. House, Drexel U.; F.O. Huck, Langley Research Center, NASA; G. Hunt, Imperial College, London U.; R. Kandel and A. Berroir, Laboratory of Dynamic Meteorology, Ecole Polytechique; V. Ramanathan, U. Chicago; E. Raschke, U. of Cologne; W.L. Smith, U. of Wisconsin and T.H. Vonder Haar, Colorado State U.

  4. 3Demonstration Results of Phytoremediation of Explosives-Contaminated Groundwater Using Constructed Wetlands at the Milan Army Ammunition Plant, Milan, Tennessee Volume III.

    DTIC Science & Technology

    1998-12-01

    10301 ~>& DEMONSTRATION RESULTS OF PHYTOREMEDIATION OF EXPLOSIVES-CONTAMINATED GROUNDWATER USING CONSTRUCTED WETLANDS AT THE MILAN ARMY...Demonstration Results of Phytoremediation of Explosives-Contaminated Groundwater Using Constructed Wetlands At The Milan Army Ammunition Plant...December 1998 2. REPORT TYPE Final 3. DATES COVERED (From - To) 4. TITLE AND SUBTITLE Demonstration Results of Phytoremediation of Explosives

  5. Summarising and validating test accuracy results across multiple studies for use in clinical practice.

    PubMed

    Riley, Richard D; Ahmed, Ikhlaaq; Debray, Thomas P A; Willis, Brian H; Noordzij, J Pieter; Higgins, Julian P T; Deeks, Jonathan J

    2015-06-15

    Following a meta-analysis of test accuracy studies, the translation of summary results into clinical practice is potentially problematic. The sensitivity, specificity and positive (PPV) and negative (NPV) predictive values of a test may differ substantially from the average meta-analysis findings, because of heterogeneity. Clinicians thus need more guidance: given the meta-analysis, is a test likely to be useful in new populations, and if so, how should test results inform the probability of existing disease (for a diagnostic test) or future adverse outcome (for a prognostic test)? We propose ways to address this. Firstly, following a meta-analysis, we suggest deriving prediction intervals and probability statements about the potential accuracy of a test in a new population. Secondly, we suggest strategies on how clinicians should derive post-test probabilities (PPV and NPV) in a new population based on existing meta-analysis results and propose a cross-validation approach for examining and comparing their calibration performance. Application is made to two clinical examples. In the first example, the joint probability that both sensitivity and specificity will be >80% in a new population is just 0.19, because of a low sensitivity. However, the summary PPV of 0.97 is high and calibrates well in new populations, with a probability of 0.78 that the true PPV will be at least 0.95. In the second example, post-test probabilities calibrate better when tailored to the prevalence in the new population, with cross-validation revealing a probability of 0.97 that the observed NPV will be within 10% of the predicted NPV. © 2015 The Authors. Statistics in Medicine Published by John Wiley & Sons Ltd.

  6. Reliability and validity of the test of incremental respiratory endurance measures of inspiratory muscle performance in COPD

    PubMed Central

    Formiga, Magno F; Roach, Kathryn E; Vital, Isabel; Urdaneta, Gisel; Balestrini, Kira; Calderon-Candelario, Rafael A

    2018-01-01

    Purpose The Test of Incremental Respiratory Endurance (TIRE) provides a comprehensive assessment of inspiratory muscle performance by measuring maximal inspiratory pressure (MIP) over time. The integration of MIP over inspiratory duration (ID) provides the sustained maximal inspiratory pressure (SMIP). Evidence on the reliability and validity of these measurements in COPD is not currently available. Therefore, we assessed the reliability, responsiveness and construct validity of the TIRE measures of inspiratory muscle performance in subjects with COPD. Patients and methods Test–retest reliability, known-groups and convergent validity assessments were implemented simultaneously in 81 male subjects with mild to very severe COPD. TIRE measures were obtained using the portable PrO2 device, following standard guidelines. Results All TIRE measures were found to be highly reliable, with SMIP demonstrating the strongest test–retest reliability with a nearly perfect intraclass correlation coefficient (ICC) of 0.99, while MIP and ID clustered closely together behind SMIP with ICC values of about 0.97. Our findings also demonstrated known-groups validity of all TIRE measures, with SMIP and ID yielding larger effect sizes when compared to MIP in distinguishing between subjects of different COPD status. Finally, our analyses confirmed convergent validity for both SMIP and ID, but not MIP. Conclusion The TIRE measures of MIP, SMIP and ID have excellent test–retest reliability and demonstrated known-groups validity in subjects with COPD. SMIP and ID also demonstrated evidence of moderate convergent validity and appear to be more stable measures in this patient population than the traditional MIP. PMID:29805255

  7. Hydrological Validation of The Lpj Dynamic Global Vegetation Model - First Results and Required Actions

    NASA Astrophysics Data System (ADS)

    Haberlandt, U.; Gerten, D.; Schaphoff, S.; Lucht, W.

    Dynamic global vegetation models are developed with the main purpose to describe the spatio-temporal dynamics of vegetation at the global scale. Increasing concern about climate change impacts has put the focus of recent applications on the sim- ulation of the global carbon cycle. Water is a prime driver of biogeochemical and biophysical processes, thus an appropriate representation of the water cycle is crucial for their proper simulation. However, these models usually lack thorough validation of the water balance they produce. Here we present a hydrological validation of the current version of the LPJ (Lund- Potsdam-Jena) model, a dynamic global vegetation model operating at daily time steps. Long-term simulated runoff and evapotranspiration are compared to literature values, results from three global hydrological models, and discharge observations from various macroscale river basins. It was found that the seasonal and spatial patterns of the LPJ-simulated average values correspond well both with the measurements and the results from the stand-alone hy- drological models. However, a general underestimation of runoff occurs, which may be attributable to the low input dynamics of precipitation (equal distribution within a month), to the simulated vegetation pattern (potential vegetation without anthro- pogenic influence), and to some generalizations of the hydrological components in LPJ. Future research will focus on a better representation of the temporal variability of climate forcing, improved description of hydrological processes, and on the consider- ation of anthropogenic land use.

  8. Performance Analysis and Electronics Packaging of the Optical Communications Demonstrator

    NASA Technical Reports Server (NTRS)

    Jeganathan, M.; Monacos, S.

    1998-01-01

    The Optical Communications Demonstrator (OCD), under development at the Jet Propulsion Laboratory (JPL), is a laboratory-based lasercomm terminal designed to validate several key technologies, primarily precision beam pointing, high bandwidth tracking, and beacon acquisition.

  9. Coupling solar photo-Fenton and biotreatment at industrial scale: main results of a demonstration plant.

    PubMed

    Malato, Sixto; Blanco, Julián; Maldonado, Manuel I; Oller, Isabel; Gernjak, Wolfgang; Pérez-Estrada, Leonidas

    2007-07-31

    This paper reports on the combined solar photo-Fenton/biological treatment of an industrial effluent (initial total organic carbon, TOC, around 500mgL(-1)) containing a non-biodegradable organic substance (alpha-methylphenylglycine at 500mgL(-1)), focusing on pilot plant tests performed for design of an industrial plant, the design itself and the plant layout. Pilot plant tests have demonstrated that biodegradability enhancement is closely related to disappearance of the parent compound, for which a certain illumination time and hydrogen peroxide consumption are required, working at pH 2.8 and adding Fe(2+)=20mgL(-1). Based on pilot plant results, an industrial plant with 100m(2) of CPC collectors for a 250L/h treatment capacity has been designed. The solar system discharges the wastewater (WW) pre-treated by photo-Fenton into a biotreatment based on an immobilized biomass reactor. First, results of the industrial plant are also presented, demonstrating that it is able to treat up to 500Lh(-1) at an average solar ultraviolet radiation of 22.9Wm(-2), under the same conditions (pH, hydrogen peroxide consumption) tested in the pilot plant.

  10. Strategic Defense Initiative Demonstration/Validation Program Environmental Assessment. Space-Based Surveillance and Tracking System (SSTS),

    DTIC Science & Technology

    1987-08-01

    take place in both contractor and government facilities. The on-orbit evaluation could utilize modified launch facilities depending on the launch...technological issues : o Telescope Optics: Verify that the distortions associated vith large optical elements satisfy detection and tracking requirements; verify...Validation program vould be car- ried out at contractor facilities that 1’ave not been identified and at six government facilities (Arnold Engineering

  11. You don't have to believe everything you read: background knowledge permits fast and efficient validation of information.

    PubMed

    Richter, Tobias; Schroeder, Sascha; Wöhrmann, Britta

    2009-03-01

    In social cognition, knowledge-based validation of information is usually regarded as relying on strategic and resource-demanding processes. Research on language comprehension, in contrast, suggests that validation processes are involved in the construction of a referential representation of the communicated information. This view implies that individuals can use their knowledge to validate incoming information in a routine and efficient manner. Consistent with this idea, Experiments 1 and 2 demonstrated that individuals are able to reject false assertions efficiently when they have validity-relevant beliefs. Validation processes were carried out routinely even when individuals were put under additional cognitive load during comprehension. Experiment 3 demonstrated that the rejection of false information occurs automatically and interferes with affirmative responses in a nonsemantic task (epistemic Stroop effect). Experiment 4 also revealed complementary interference effects of true information with negative responses in a nonsemantic task. These results suggest the existence of fast and efficient validation processes that protect mental representations from being contaminated by false and inaccurate information.

  12. The design organization test: further demonstration of reliability and validity as a brief measure of visuospatial ability.

    PubMed

    Killgore, William D S; Gogel, Hannah

    2014-01-01

    Neuropsychological assessments are frequently time-consuming and fatiguing for patients. Brief screening evaluations may reduce test duration and allow more efficient use of time by permitting greater attention toward neuropsychological domains showing probable deficits. The Design Organization Test (DOT) was initially developed as a 2-min paper-and-pencil alternative for the Block Design (BD) subtest of the Wechsler scales. Although initially validated for clinical neurologic patients, we sought to further establish the reliability and validity of this test in a healthy, more diverse population. Two alternate versions of the DOT and the Wechsler Abbreviated Scale of Intelligence (WASI) were administered to 61 healthy adult participants. The DOT showed high alternate forms reliability (r = .90-.92), and the two versions yielded equivalent levels of performance. The DOT was highly correlated with BD (r = .76-.79) and was significantly correlated with all subscales of the WASI. The DOT proved useful when used in lieu of BD in the calculation of WASI IQ scores. Findings support the reliability and validity of the DOT as a measure of visuospatial ability and suggest its potential worth as an efficient estimate of intellectual functioning in situations where lengthier tests may be inappropriate or unfeasible.

  13. The selection of air traffic control specialists : two studies demonstrating methods to insure an accurate validity coefficient for selection devices.

    DOT National Transportation Integrated Search

    1979-03-01

    There are several conditions that can influence the calculation of the statistical validity of a test battery such as that used to selected Air Traffic Control Specialists. Two conditions of prime importance to statistical validity are recruitment pr...

  14. Measuring Nutrition Literacy in Spanish-Speaking Latinos: An Exploratory Validation Study.

    PubMed

    Gibbs, Heather D; Camargo, Juliana M T B; Owens, Sarah; Gajewski, Byron; Cupertino, Ana Paula

    2017-11-21

    Nutrition is important for preventing and treating chronic diseases highly prevalent among Latinos, yet no tool exists for measuring nutrition literacy among Spanish speakers. This study aimed to adapt the validated Nutrition Literacy Assessment Instrument for Spanish-speaking Latinos. This study was developed in two phases: adaptation and validity testing. Adaptation included translation, expert item content review, and interviews with Spanish speakers. For validity testing, 51 participants completed the Short Assessment of Health Literacy-Spanish (SAHL-S), the Nutrition Literacy Assessment Instrument in Spanish (NLit-S), and socio-demographic questionnaire. Validity and reliability statistics were analyzed. Content validity was confirmed with a Scale Content Validity Index of 0.96. Validity testing demonstrated NLit-S scores were strongly correlated with SAHL-S scores (r = 0.52, p < 0.001). Entire reliability was substantial at 0.994 (CI 0.992-0.996) and internal consistency was excellent (Cronbach's α = 0.92). The NLit-S demonstrates validity and reliability for measuring nutrition literacy among Spanish-speakers.

  15. Long-term PAH monitoring results from the Anacostia River active capping demonstration using polydimethylsiloxane (PDMS) fibers.

    PubMed

    Lampert, David J; Lu, Xiaoxia; Reible, Danny D

    2013-03-01

    In this paper, the long-term monitoring results for hydrophobic organic compounds, specifically polycyclic aromatic hydrocarbons (PAHs), from a field demonstration of capping contaminated sediments at the Anacostia River in Washington DC are presented and analyzed. In situ pore water concentrations in field-contaminated sediments in the demonstration caps were quantified using a polydimethylsiloxane (PDMS)-based passive sampling device. High resolution vertical pore water concentration profiles were measured using the device and were used to infer fate and transport of polycyclic aromatics hydrocarbons (PAHs) at the site. The derived pore water concentrations were compared with observed bioaccumulation and solid-phase concentration profiles to infer contaminant migration rates and mechanisms. Observed pore water concentrations were found to be a better predictor of bioaccumulation than solid-phase concentrations. Solid-phase concentrations were low in cores which implied containment of contamination; however pore water profiles showed that contaminant migration had occurred in the first few years after cap placement. The discrepancy is the result of the low sorption capacity of the sand. Because of surface re-contamination, low sorption capacity in the demonstration caps and strong tidal pumping effects, steady state contaminant profiles were reached in the caps several years after placement. Despite re-contamination at the surface, steady state concentrations in the capped areas showed decreased contamination levels relative to the control area.

  16. A Post-Processing Receiver for the Lunar Laser Communications Demonstration Project

    NASA Technical Reports Server (NTRS)

    Srinivasan, Meera; Birnbaum, Kevin; Cheng, Michael; Quirk, Kevin

    2013-01-01

    The Lunar Laser Communications Demonstration Project undertaken by MIT Lincoln Laboratory and NASA's Goddard Space Flight Center will demonstrate high-rate laser communications from lunar orbit to the Earth. NASA's Jet Propulsion Laboratory is developing a backup ground station supporting a data rate of 39 Mbps that is based on a non-real-time software post-processing receiver architecture. This approach entails processing sample-rate-limited data without feedback in the presence high uncertainty in downlink clock characteristics under low signal flux conditions. In this paper we present a receiver concept that addresses these challenges with descriptions of the photodetector assembly, sample acquisition and recording platform, and signal processing approach. End-to-end coded simulation and laboratory data analysis results are presented that validate the receiver conceptual design.

  17. [Nursing on the Web: the creation and validation process of a web site on coronary artery disease].

    PubMed

    Marques, Isaac Rosa; Marin, Heimar de Fátima

    2002-01-01

    The World Wide Web is an important health information research source. A challenge for the Brazilian Nursing Informatics area is to use its potential to promote health education. This paper aims to present a developing and validating model used in an educational Web site, named CardioSite, which subject is Coronary Heart Disease. In its creation it was adopted a method with phases of conceptual modeling, development, implementation, and evaluation. In the evaluation phase, the validation was performed through an online informatics and health experts panel. The results demonstrated that information was reliable and valid. Considering that national official systems are not available to that approach, this model demonstrated effectiveness in assessing the quality of the Web site content.

  18. A validation framework for brain tumor segmentation.

    PubMed

    Archip, Neculai; Jolesz, Ferenc A; Warfield, Simon K

    2007-10-01

    We introduce a validation framework for the segmentation of brain tumors from magnetic resonance (MR) images. A novel unsupervised semiautomatic brain tumor segmentation algorithm is also presented. The proposed framework consists of 1) T1-weighted MR images of patients with brain tumors, 2) segmentation of brain tumors performed by four independent experts, 3) segmentation of brain tumors generated by a semiautomatic algorithm, and 4) a software tool that estimates the performance of segmentation algorithms. We demonstrate the validation of the novel segmentation algorithm within the proposed framework. We show its performance and compare it with existent segmentation. The image datasets and software are available at http://www.brain-tumor-repository.org/. We present an Internet resource that provides access to MR brain tumor image data and segmentation that can be openly used by the research community. Its purpose is to encourage the development and evaluation of segmentation methods by providing raw test and image data, human expert segmentation results, and methods for comparing segmentation results.

  19. An intercomparison of a large ensemble of statistical downscaling methods for Europe: Overall results from the VALUE perfect predictor cross-validation experiment

    NASA Astrophysics Data System (ADS)

    Gutiérrez, Jose Manuel; Maraun, Douglas; Widmann, Martin; Huth, Radan; Hertig, Elke; Benestad, Rasmus; Roessler, Ole; Wibig, Joanna; Wilcke, Renate; Kotlarski, Sven

    2016-04-01

    VALUE is an open European network to validate and compare downscaling methods for climate change research (http://www.value-cost.eu). A key deliverable of VALUE is the development of a systematic validation framework to enable the assessment and comparison of both dynamical and statistical downscaling methods. This framework is based on a user-focused validation tree, guiding the selection of relevant validation indices and performance measures for different aspects of the validation (marginal, temporal, spatial, multi-variable). Moreover, several experiments have been designed to isolate specific points in the downscaling procedure where problems may occur (assessment of intrinsic performance, effect of errors inherited from the global models, effect of non-stationarity, etc.). The list of downscaling experiments includes 1) cross-validation with perfect predictors, 2) GCM predictors -aligned with EURO-CORDEX experiment- and 3) pseudo reality predictors (see Maraun et al. 2015, Earth's Future, 3, doi:10.1002/2014EF000259, for more details). The results of these experiments are gathered, validated and publicly distributed through the VALUE validation portal, allowing for a comprehensive community-open downscaling intercomparison study. In this contribution we describe the overall results from Experiment 1), consisting of a European wide 5-fold cross-validation (with consecutive 6-year periods from 1979 to 2008) using predictors from ERA-Interim to downscale precipitation and temperatures (minimum and maximum) over a set of 86 ECA&D stations representative of the main geographical and climatic regions in Europe. As a result of the open call for contribution to this experiment (closed in Dec. 2015), over 40 methods representative of the main approaches (MOS and Perfect Prognosis, PP) and techniques (linear scaling, quantile mapping, analogs, weather typing, linear and generalized regression, weather generators, etc.) were submitted, including information both data

  20. Assessment of the face validity of two pain scales in Kenya: a validation study using cognitive interviewing

    PubMed Central

    2012-01-01

    Background Patients in sub-Saharan Africa commonly experience pain, which often is un-assessed and undertreated. One hindrance to routine pain assessment in these settings is the lack of a single-item pain rating scale validated for the particular context. The goal of this study was to examine the face validity and cultural acceptability of two single-item pain scales, the Numerical Rating Scale (NRS) and the Faces Pain Scale-Revised (FPS-R), in a population of patients on the medical, surgical, and pediatric wards of Moi Teaching and Referral Hospital in Kenya. Methods Swahili versions of the NRS and FPS-R were developed by standard translation and back-translation. Cognitive interviews were performed with 15 patients at Moi Teaching and Referral Hospital in Eldoret, Kenya. Interview transcripts were analyzed on a question-by-question basis to identify major themes revealed through the cognitive interviewing process and to uncover any significant problems participants encountered with understanding and using the pain scales. Results Cognitive interview analysis demonstrated that participants had good comprehension of both the NRS and the FPS-R and showed rational decision-making processes in choosing their responses. Participants felt that both scales were easy to use. The FPS-R was preferred almost unanimously to the NRS. Conclusions The face validity and acceptability of the Swahili versions of the NRS and FPS-R has been demonstrated for use in Kenyan patients. The broader application of these scales should be evaluated and may benefit patients who currently suffer from pain. PMID:22512923

  1. Airborne Validation of Spatial Properties Measured by the CALIPSO Lidar

    NASA Technical Reports Server (NTRS)

    McGill, Matthew J.; Vaughan, Mark A.; Trepte, Charles Reginald; Hart, William D.; Hlavka, Dennis L.; Winker, David M.; Keuhn, Ralph

    2007-01-01

    The primary payload onboard the Cloud-Aerosol Lidar Infrared Pathfinder Satellite Observations (CALIPSO) satellite is a dual-wavelength backscatter lidar designed to provide vertical profiling of clouds and aerosols. Launched in April 2006, the first data from this new satellite was obtained in June 2006. As with any new satellite measurement capability, an immediate post-launch requirement is to verify that the data being acquired is correct lest scientific conclusions begin to be drawn based on flawed data. A standard approach to verifying satellite data is to take a similar, or validation, instrument and fly it onboard a research aircraft. Using an aircraft allows the validation instrument to get directly under the satellite so that both the satellite instrument and the aircraft instrument are sensing the same region of the atmosphere. Although there are almost always some differences in the sampling capabilities of the two instruments, it is nevertheless possible to directly compare the measurements. To validate the measurements from the CALIPSO lidar, a similar instrument, the Cloud Physics Lidar, was flown onboard the NASA high-altitude ER-2 aircraft during July- August 2006. This paper presents results to demonstrate that the CALIPSO lidar is properly calibrated and the CALIPSO Level 1 data products are correct. The importance of the results is to demonstrate to the research community that CALIPSO Level 1 data can be confidently used for scientific research.

  2. Using Neural Networks for Sensor Validation

    NASA Technical Reports Server (NTRS)

    Mattern, Duane L.; Jaw, Link C.; Guo, Ten-Huei; Graham, Ronald; McCoy, William

    1998-01-01

    This paper presents the results of applying two different types of neural networks in two different approaches to the sensor validation problem. The first approach uses a functional approximation neural network as part of a nonlinear observer in a model-based approach to analytical redundancy. The second approach uses an auto-associative neural network to perform nonlinear principal component analysis on a set of redundant sensors to provide an estimate for a single failed sensor. The approaches are demonstrated using a nonlinear simulation of a turbofan engine. The fault detection and sensor estimation results are presented and the training of the auto-associative neural network to provide sensor estimates is discussed.

  3. Satisfaction with information provided to Danish cancer patients: validation and survey results.

    PubMed

    Ross, Lone; Petersen, Morten Aagaard; Johnsen, Anna Thit; Lundstrøm, Louise Hyldborg; Groenvold, Mogens

    2013-11-01

    To validate five items (CPWQ-inf) regarding satisfaction with information provided to cancer patients from health care staff, assess the prevalence of dissatisfaction with this information, and identify factors predicting dissatisfaction. The questionnaire was validated by patient-observer agreement and cognitive interviews. The prevalence of dissatisfaction was assessed in a cross-sectional sample of all cancer patients in contact with hospitals during the past year in three Danish counties. The validation showed that the CPWQ performed well. Between 3 and 23% of the 1490 participating patients were dissatisfied with each of the measured aspects of information. The highest level of dissatisfaction was reported regarding the guidance, support and help provided when the diagnosis was given. Younger patients were consistently more dissatisfied than older patients. The brief CPWQ performs well for survey purposes. The survey depicts the heterogeneous patient population encountered by hospital staff and showed that younger patients probably had higher expectations or a higher need for information and that those with more severe diagnoses/prognoses require extra care in providing information. Four brief questions can efficiently assess information needs. With increasing demands for information, a wide range of innovative initiatives is needed. Copyright © 2013 Elsevier Ireland Ltd. All rights reserved.

  4. Validating EHR clinical models using ontology patterns.

    PubMed

    Martínez-Costa, Catalina; Schulz, Stefan

    2017-12-01

    Clinical models are artefacts that specify how information is structured in electronic health records (EHRs). However, the makeup of clinical models is not guided by any formal constraint beyond a semantically vague information model. We address this gap by advocating ontology design patterns as a mechanism that makes the semantics of clinical models explicit. This paper demonstrates how ontology design patterns can validate existing clinical models using SHACL. Based on the Clinical Information Modelling Initiative (CIMI), we show how ontology patterns detect both modeling and terminology binding errors in CIMI models. SHACL, a W3C constraint language for the validation of RDF graphs, builds on the concept of "Shape", a description of data in terms of expected cardinalities, datatypes and other restrictions. SHACL, as opposed to OWL, subscribes to the Closed World Assumption (CWA) and is therefore more suitable for the validation of clinical models. We have demonstrated the feasibility of the approach by manually describing the correspondences between six CIMI clinical models represented in RDF and two SHACL ontology design patterns. Using a Java-based SHACL implementation, we found at least eleven modeling and binding errors within these CIMI models. This demonstrates the usefulness of ontology design patterns not only as a modeling tool but also as a tool for validation. Copyright © 2017 Elsevier Inc. All rights reserved.

  5. Real-time sensor data validation

    NASA Technical Reports Server (NTRS)

    Bickmore, Timothy W.

    1994-01-01

    This report describes the status of an on-going effort to develop software capable of detecting sensor failures on rocket engines in real time. This software could be used in a rocket engine controller to prevent the erroneous shutdown of an engine due to sensor failures which would otherwise be interpreted as engine failures by the control software. The approach taken combines analytical redundancy with Bayesian belief networks to provide a solution which has well defined real-time characteristics and well-defined error rates. Analytical redundancy is a technique in which a sensor's value is predicted by using values from other sensors and known or empirically derived mathematical relations. A set of sensors and a set of relations among them form a network of cross-checks which can be used to periodically validate all of the sensors in the network. Bayesian belief networks provide a method of determining if each of the sensors in the network is valid, given the results of the cross-checks. This approach has been successfully demonstrated on the Technology Test Bed Engine at the NASA Marshall Space Flight Center. Current efforts are focused on extending the system to provide a validation capability for 100 sensors on the Space Shuttle Main Engine.

  6. Issues in cross-cultural validity: example from the adaptation, reliability, and validity testing of a Turkish version of the Stanford Health Assessment Questionnaire.

    PubMed

    Küçükdeveci, Ayse A; Sahin, Hülya; Ataman, Sebnem; Griffiths, Bridget; Tennant, Alan

    2004-02-15

    Guidelines have been established for cross-cultural adaptation of outcome measures. However, invariance across cultures must also be demonstrated through analysis of Differential Item Functioning (DIF). This is tested in the context of a Turkish adaptation of the Health Assessment Questionnaire (HAQ). Internal construct validity of the adapted HAQ is assessed by Rasch analysis; reliability, by internal consistency and the intraclass correlation coefficient; external construct validity, by association with impairments and American College of Rheumatology functional stages. Cross-cultural validity is tested through DIF by comparison with data from the UK version of the HAQ. The adapted version of the HAQ demonstrated good internal construct validity through fit of the data to the Rasch model (mean item fit 0.205; SD 0.998). Reliability was excellent (alpha = 0.97) and external construct validity was confirmed by expected associations. DIF for culture was found in only 1 item. Cross-cultural validity was found to be sufficient for use in international studies between the UK and Turkey. Future adaptation of instruments should include analysis of DIF at the field testing stage in the adaptation process.

  7. Preliminary test results from a free-piston Stirling engine technology demonstration program to support advanced radioisotope space power applications

    NASA Astrophysics Data System (ADS)

    White, Maurice A.; Qiu, Songgang; Augenblick, Jack E.

    2000-01-01

    Free-piston Stirling engines offer a relatively mature, proven, long-life technology that is well-suited for advanced, high-efficiency radioisotope space power systems. Contracts from DOE and NASA are being conducted by Stirling Technology Company (STC) for the purpose of demonstrating the Stirling technology in a configuration and power level that is representative of an eventual space power system. The long-term objective is to develop a power system with an efficiency exceeding 20% that can function with a high degree of reliability for up to 15 years on deep space missions. The current technology demonstration convertors (TDC's) are completing shakedown testing and have recently demonstrated performance levels that are virtually identical to projections made during the preliminary design phase. This paper describes preliminary test results for power output, efficiency, and vibration levels. These early results demonstrate the ability of the free-piston Stirling technology to exceed objectives by approximately quadrupling the efficiency of conventional radioisotope thermoelectric generators (RTG's). .

  8. An integrated bioanalytical method development and validation approach: case studies.

    PubMed

    Xue, Y-J; Melo, Brian; Vallejo, Martha; Zhao, Yuwen; Tang, Lina; Chen, Yuan-Shek; Keller, Karin M

    2012-10-01

    We proposed an integrated bioanalytical method development and validation approach: (1) method screening based on analyte's physicochemical properties and metabolism information to determine the most appropriate extraction/analysis conditions; (2) preliminary stability evaluation using both quality control and incurred samples to establish sample collection, storage and processing conditions; (3) mock validation to examine method accuracy and precision and incurred sample reproducibility; and (4) method validation to confirm the results obtained during method development. This integrated approach was applied to the determination of compound I in rat plasma and compound II in rat and dog plasma. The effectiveness of the approach was demonstrated by the superior quality of three method validations: (1) a zero run failure rate; (2) >93% of quality control results within 10% of nominal values; and (3) 99% incurred sample within 9.2% of the original values. In addition, rat and dog plasma methods for compound II were successfully applied to analyze more than 900 plasma samples obtained from Investigational New Drug (IND) toxicology studies in rats and dogs with near perfect results: (1) a zero run failure rate; (2) excellent accuracy and precision for standards and quality controls; and (3) 98% incurred samples within 15% of the original values. Copyright © 2011 John Wiley & Sons, Ltd.

  9. Validation of the Japanese Version of the Body Vigilance Scale.

    PubMed

    Saigo, Tatsuo; Takebayashi, Yoshitake; Tayama, Jun; Bernick, Peter J; Schmidt, Norman B; Shirabe, Susumu; Sakano, Yuji

    2016-06-01

    The Body Vigilance Scale is a self-report measure of attention to bodily sensations. The measure was translated into Japanese and its reliability, validity, and factor structure were verified. Participants comprised 286 university students (age: 19 ± 1 years). All participants were administered the scale, along with several indices of anxiety (i.e., Anxiety Sensitivity Index, Short Health Anxiety Inventory Illness Likelihood Scale, Social Interaction Anxiety Scale, and Hospital Anxiety and Depression Scale). The Japanese version of the Body Vigilance Scale exhibited a unidimensional factor structure and strong internal consistency. Construct validity was demonstrated by significant correlations with the above measures. Results suggest that the Japanese version of the scale is a reliable, valid tool for measuring body vigilance in Japanese university students. © The Author(s) 2016.

  10. Demonstration Results of Phytoremediation of Explosives-Contaminated Groundwater Using Constructed Wetlands at the Milan Army Ammunition Plant, Milan, Tennessee Volume I (Phase II Demonstration Results).

    DTIC Science & Technology

    1998-12-01

    influence community respiration, photosynthesis, solubility of dissolved oxygen, redox potential, biochemical reaction rates, and ensuing treatment...Conductivity 15-8 15.1.3.5 Dissolved Oxygen Concentration 15-12 15.1.3.6 Redox Potential 15-14 15.1.3.7 pH 15-16 15.1.3.8 Nutrients and Water Quality 15-19...Average Redox Potential of Wetland Waters From June 17, 6-27 1996, to September 16, 1997 Phytoremediation Demonstration Milan AAP FIGURE NUMBER

  11. Reliable and valid assessment of point-of-care ultrasonography.

    PubMed

    Todsen, Tobias; Tolsgaard, Martin Grønnebæk; Olsen, Beth Härstedt; Henriksen, Birthe Merete; Hillingsø, Jens Georg; Konge, Lars; Jensen, Morten Lind; Ringsted, Charlotte

    2015-02-01

    To explore the reliability and validity of the Objective Structured Assessment of Ultrasound Skills (OSAUS) scale for point-of-care ultrasonography (POC US) performance. POC US is increasingly used by clinicians and is an essential part of the management of acute surgical conditions. However, the quality of performance is highly operator-dependent. Therefore, reliable and valid assessment of trainees' ultrasonography competence is needed to ensure patient safety. Twenty-four physicians, representing novices, intermediates, and experts in POC US, scanned 4 different surgical patient cases in a controlled set-up. All ultrasound examinations were video-recorded and assessed by 2 blinded radiologists using OSAUS. Reliability was examined using generalizability theory. Construct validity was examined by comparing performance scores between the groups and by correlating physicians' OSAUS scores with diagnostic accuracy. The generalizability coefficient was high (0.81) and a D-study demonstrated that 1 assessor and 5 cases would result in similar reliability. The construct validity of the OSAUS scale was supported by a significant difference in the mean scores between the novice group (17.0; SD 8.4) and the intermediate group (30.0; SD 10.1), P = 0.007, as well as between the intermediate group and the expert group (72.9; SD 4.4), P = 0.04, and by a high correlation between OSAUS scores and diagnostic accuracy (Spearman ρ correlation coefficient = 0.76; P < 0.001). This study demonstrates high reliability as well as evidence of construct validity of the OSAUS scale for assessment of POC US competence. Hence, the OSAUS scale may be suitable for both in-training as well as end-of-training assessment.

  12. The PROPEL Electrodynamic Tether Demonstration Mission

    NASA Technical Reports Server (NTRS)

    Bilen, Sven G.; Johnson, C. Les; Wiegmann, Bruce M.; Alexander, Leslie; Gilchrist, Brian E.; Hoyt, Robert P.; Elder, Craig H.; Fuhrhop, Keith P.; Scadera, Michael

    2012-01-01

    The PROPEL ("Propulsion using Electrodynamics") mission will demonstrate the operation of an electrodynamic tether propulsion system in low Earth orbit and advance its technology readiness level for multiple applications. The PROPEL mission has two primary objectives: first, to demonstrate the capability of electrodynamic tether technology to provide robust and safe, near-propellantless propulsion for orbit-raising, de-orbit, plane change, and station keeping, as well as to perform orbital power harvesting and formation flight; and, second, to fully characterize and validate the performance of an integrated electrodynamic tether propulsion system, qualifying it for infusion into future multiple satellite platforms and missions with minimal modification. This paper provides an overview of the PROPEL system and design reference missions; mission goals and required measurements; and ongoing PROPEL mission design efforts.

  13. Foundation Heat Exchanger Final Report: Demonstration, Measured Performance, and Validated Model and Design Tool

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Hughes, Patrick; Im, Piljae

    2012-04-01

    exchanger (FHX) has been coined to refer exclusively to ground heat exchangers installed in the overcut around the basement walls. The primary technical challenge undertaken by this project was the development and validation of energy performance models and design tools for FHX. In terms of performance modeling and design, ground heat exchangers in other construction excavations (e.g., utility trenches) are no different from conventional HGHX, and models and design tools for HGHX already exist. This project successfully developed and validated energy performance models and design tools so that FHX or hybrid FHX/HGHX systems can be engineered with confidence, enabling this technology to be applied in residential and light commercial buildings. The validated energy performance model also addresses and solves another problem, the longstanding inadequacy in the way ground-building thermal interaction is represented in building energy models, whether or not there is a ground heat exchanger nearby. Two side-by-side, three-level, unoccupied research houses with walkout basements, identical 3,700 ft{sup 2} floor plans, and hybrid FHX/HGHX systems were constructed to provide validation data sets for the energy performance model and design tool. The envelopes of both houses are very energy efficient and airtight, and the HERS ratings of the homes are 44 and 45 respectively. Both houses are mechanically ventilated with energy recovery ventilators, with space conditioning provided by water-to-air heat pumps with 2 ton nominal capacities. Separate water-to-water heat pumps with 1.5 ton nominal capacities were used for water heating. In these unoccupied research houses, human impact on energy use (hot water draw, etc.) is simulated to match the national average. At House 1 the hybrid FHX/HGHX system was installed in 300 linear feet of excavation, and 60% of that was construction excavation (needed to construct the home). At House 2 the hybrid FHX/HGHX system was installed in 360 feet of

  14. Generalizing disease management program results: how to get from here to there.

    PubMed

    Linden, Ariel; Adams, John L; Roberts, Nancy

    2004-07-01

    For a disease management (DM) program, the ability to generalize results from the intervention group to the population, to other populations, or to other diseases is as important as demonstrating internal validity. This article provides an overview of the threats to external validity of DM programs, and offers methods to improve the capability for generalizing results obtained through the program. The external validity of DM programs must be evaluated even before program selection and implementation are begun with a prospective new client. Any fundamental differences in characteristics between individuals in an established DM program and in a new population/environment may limit the ability to generalize.

  15. Validation of the Physician Teaching Motivation Questionnaire (PTMQ).

    PubMed

    Dybowski, Christoph; Harendza, Sigrid

    2015-10-02

    Physicians play a major role as teachers in undergraduate medical education. Studies indicate that different forms and degrees of motivation can influence work performance in general and that teachers' motivation to teach can influence students' academic achievements in particular. Therefore, the aim of this study was to develop and to validate an instrument measuring teaching motivations in hospital-based physicians. We chose self-determination theory as a theoretical framework for item and scale development. It distinguishes between different dimensions of motivation depending on the amount of self-regulation and autonomy involved and its empirical evidence has been demonstrated in other areas of research. To validate the new instrument (PTMQ = Physician Teaching Motivation Questionnaire), we used data from a sample of 247 physicians from internal medicine and surgery at six German medical faculties. Structural equation modelling was conducted to confirm the factorial structure, correlation analyses and linear regressions were performed to examine concurrent and incremental validity. Structural equation modelling confirmed a good global fit for the factorial structure of the final instrument (RMSEA = .050, TLI = .957, SRMR = .055, CFI = .966). Cronbach's alphas indicated good internal consistencies for all scales (α = .75 - .89) except for the identified teaching motivation subscale with an acceptable internal consistency (α = .65). Tests of concurrent validity with global work motivation, perceived teaching competence, perceived teaching involvement and voluntariness of lesson allocation delivered theory-consistent results with slight deviations for some scales. Incremental validity over global work motivation in predicting perceived teaching involvement was also confirmed. Our results indicate that the PTMQ is a reliable, valid and therefore suitable instrument for assessing physicians' teaching motivation.

  16. Point-to-Point! Validation of the Small Aircraft Transportation System Higher Volume Operations Concept

    NASA Technical Reports Server (NTRS)

    Williams, Daniel M.

    2006-01-01

    Described is the research process that NASA researchers used to validate the Small Aircraft Transportation System (SATS) Higher Volume Operations (HVO) concept. The four phase building-block validation and verification process included multiple elements ranging from formal analysis of HVO procedures to flight test, to full-system architecture prototype that was successfully shown to the public at the June 2005 SATS Technical Demonstration in Danville, VA. Presented are significant results of each of the four research phases that extend early results presented at ICAS 2004. HVO study results have been incorporated into the development of the Next Generation Air Transportation System (NGATS) vision and offer a validated concept to provide a significant portion of the 3X capacity improvement sought after in the United States National Airspace System (NAS).

  17. Geometric Demonstration of the Fundamental Theorems of the Calculus

    ERIC Educational Resources Information Center

    Sauerheber, Richard D.

    2010-01-01

    After the monumental discovery of the fundamental theorems of the calculus nearly 350 years ago, it became possible to answer extremely complex questions regarding the natural world. Here, a straightforward yet profound demonstration, employing geometrically symmetric functions, describes the validity of the general power rules for integration and…

  18. Validity and reliability of Patient-Reported Outcomes Measurement Information System (PROMIS) Instruments in Osteoarthritis

    PubMed Central

    Broderick, Joan E.; Schneider, Stefan; Junghaenel, Doerte U.; Schwartz, Joseph E.; Stone, Arthur A.

    2013-01-01

    Objective Evaluation of known group validity, ecological validity, and test-retest reliability of four domain instruments from the Patient Reported Outcomes Measurement System (PROMIS) in osteoarthritis (OA) patients. Methods Recruitment of an osteoarthritis sample and a comparison general population (GP) through an Internet survey panel. Pain intensity, pain interference, physical functioning, and fatigue were assessed for 4 consecutive weeks with PROMIS short forms on a daily basis and compared with same-domain Computer Adaptive Test (CAT) instruments that use a 7-day recall. Known group validity (comparison of OA and GP), ecological validity (comparison of aggregated daily measures with CATs), and test-retest reliability were evaluated. Results The recruited samples matched (age, sex, race, ethnicity) the demographic characteristics of the U.S. sample for arthritis and the 2009 Census for the GP. Compliance with repeated measurements was excellent: > 95%. Known group validity for CATs was demonstrated with large effect sizes (pain intensity: 1.42, pain interference: 1.25, and fatigue: .85). Ecological validity was also established through high correlations between aggregated daily measures and weekly CATs (≥ .86). Test-retest validity (7-day) was very good (≥ .80). Conclusion PROMIS CAT instruments demonstrated known group and ecological validity in a comparison of osteoarthritis patients with a general population sample. Adequate test-retest reliability was also observed. These data provide encouraging initial data on the utility of these PROMIS instruments for clinical and research outcomes in osteoarthritis patients. PMID:23592494

  19. [Active ageing and quality of life--Results of a WHO demonstration project].

    PubMed

    von dem Knesebeck, O; David, K; Bill, P; Hikl, R

    2006-04-01

    Based on the Active Ageing Programme of the World Health Organization (WHO), a demonstration project was conducted in a city in North-Rhine Westphalia between October 2002 and December 2004. The aim of the study was to promote an active ageing process, to maintain autonomy and independence among older people, and thereby to promote health and quality of life. The target group included people aged 55 to 80 years. The aim was to include older persons in a critical period of life due to loss of partner within the last five years and people undergoing a status change due to retirement within the last two years. 344 participants were visited at home to assess their health and psychosocial situation and to identify opportunities for activities. Participants were supported in their efforts to realise the agreed-upon activities. In this article results of the external evaluation are presented. It is analysed whether quality of life according to the WHOQOL Bref improves among participants in the course of the project. Results of non-parametric tests show small differences in quality of life between the three waves of interviews (at the beginning of the project, after one year, at the end of the project). This holds true when only those participants are analysed who retired within the last two years. However, quality of life significantly improves among older persons who lost their partner within the last five years. In terms of implementation of the WHO Active Ageing Programme results suggest application of a risk group strategy.

  20. Integration and Validation of Hysteroscopy Simulation in the Surgical Training Curriculum.

    PubMed

    Elessawy, Mohamed; Skrzipczyk, Moritz; Eckmann-Scholz, Christel; Maass, Nicolai; Mettler, Liselotte; Guenther, Veronika; van Mackelenbergh, Marion; Bauerschlag, Dirk O; Alkatout, Ibrahim

    The primary objective of our study was to test the construct validity of the HystSim hysteroscopic simulator to determine whether simulation training can improve the acquisition of hysteroscopic skills regardless of the previous levels of experience of the participants. The secondary objective was to analyze the performance of a selected task, using specially designed scoring charts to help reduce the learning curve for both novices and experienced surgeons. The teaching of hysteroscopic intervention has received only scant attention, focusing mainly on the development of physical models and box simulators. This encouraged our working group to search for a suitable hysteroscopic simulator module and to test its validation. We decided to use the HystSim hysteroscopic simulator, which is one of the few such simulators that has already completed a validation process, with high ratings for both realism and training capacity. As a testing tool for our study, we selected the myoma resection task. We analyzed the results using the multimetric score system suggested by HystSim, allowing a more precise interpretation of the results. Between June 2014 and May 2015, our group collected data on 57 participants of minimally invasive surgical training courses at the Kiel School of Gynecological Endoscopy, Department of Gynecology and Obstetrics, University Hospitals Schleswig-Holstein, Campus Kiel. The novice group consisted of 42 medical students and residents with no prior experience in hysteroscopy, whereas the expert group consisted of 15 participants with more than 2 years of experience of advanced hysteroscopy operations. The overall results demonstrated that all participants attained significant improvements between their pretest and posttests, independent of their previous levels of experience (p < 0.002). Those in the expert group demonstrated statistically significant, superior scores in the pretest and posttests (p = 0.001, p = 0.006). Regarding visualization and

  1. Risk-based Methodology for Validation of Pharmaceutical Batch Processes.

    PubMed

    Wiles, Frederick

    2013-01-01

    In January 2011, the U.S. Food and Drug Administration published new process validation guidance for pharmaceutical processes. The new guidance debunks the long-held industry notion that three consecutive validation batches or runs are all that are required to demonstrate that a process is operating in a validated state. Instead, the new guidance now emphasizes that the level of monitoring and testing performed during process performance qualification (PPQ) studies must be sufficient to demonstrate statistical confidence both within and between batches. In some cases, three qualification runs may not be enough. Nearly two years after the guidance was first published, little has been written defining a statistical methodology for determining the number of samples and qualification runs required to satisfy Stage 2 requirements of the new guidance. This article proposes using a combination of risk assessment, control charting, and capability statistics to define the monitoring and testing scheme required to show that a pharmaceutical batch process is operating in a validated state. In this methodology, an assessment of process risk is performed through application of a process failure mode, effects, and criticality analysis (PFMECA). The output of PFMECA is used to select appropriate levels of statistical confidence and coverage which, in turn, are used in capability calculations to determine when significant Stage 2 (PPQ) milestones have been met. The achievement of Stage 2 milestones signals the release of batches for commercial distribution and the reduction of monitoring and testing to commercial production levels. Individuals, moving range, and range/sigma charts are used in conjunction with capability statistics to demonstrate that the commercial process is operating in a state of statistical control. The new process validation guidance published by the U.S. Food and Drug Administration in January of 2011 indicates that the number of process validation batches

  2. The Validity of Conscientiousness Is Overestimated in the Prediction of Job Performance.

    PubMed

    Kepes, Sven; McDaniel, Michael A

    2015-01-01

    Sensitivity analyses refer to investigations of the degree to which the results of a meta-analysis remain stable when conditions of the data or the analysis change. To the extent that results remain stable, one can refer to them as robust. Sensitivity analyses are rarely conducted in the organizational science literature. Despite conscientiousness being a valued predictor in employment selection, sensitivity analyses have not been conducted with respect to meta-analytic estimates of the correlation (i.e., validity) between conscientiousness and job performance. To address this deficiency, we reanalyzed the largest collection of conscientiousness validity data in the personnel selection literature and conducted a variety of sensitivity analyses. Publication bias analyses demonstrated that the validity of conscientiousness is moderately overestimated (by around 30%; a correlation difference of about .06). The misestimation of the validity appears to be due primarily to suppression of small effects sizes in the journal literature. These inflated validity estimates result in an overestimate of the dollar utility of personnel selection by millions of dollars and should be of considerable concern for organizations. The fields of management and applied psychology seldom conduct sensitivity analyses. Through the use of sensitivity analyses, this paper documents that the existing literature overestimates the validity of conscientiousness in the prediction of job performance. Our data show that effect sizes from journal articles are largely responsible for this overestimation.

  3. Validity and validation of expert (Q)SAR systems.

    PubMed

    Hulzebos, E; Sijm, D; Traas, T; Posthumus, R; Maslankiewicz, L

    2005-08-01

    At a recent workshop in Setubal (Portugal) principles were drafted to assess the suitability of (quantitative) structure-activity relationships ((Q)SARs) for assessing the hazards and risks of chemicals. In the present study we applied some of the Setubal principles to test the validity of three (Q)SAR expert systems and validate the results. These principles include a mechanistic basis, the availability of a training set and validation. ECOSAR, BIOWIN and DEREK for Windows have a mechanistic or empirical basis. ECOSAR has a training set for each QSAR. For half of the structural fragments the number of chemicals in the training set is >4. Based on structural fragments and log Kow, ECOSAR uses linear regression to predict ecotoxicity. Validating ECOSAR for three 'valid' classes results in predictivity of > or = 64%. BIOWIN uses (non-)linear regressions to predict the probability of biodegradability based on fragments and molecular weight. It has a large training set and predicts non-ready biodegradability well. DEREK for Windows predictions are supported by a mechanistic rationale and literature references. The structural alerts in this program have been developed with a training set of positive and negative toxicity data. However, to support the prediction only a limited number of chemicals in the training set is presented to the user. DEREK for Windows predicts effects by 'if-then' reasoning. The program predicts best for mutagenicity and carcinogenicity. Each structural fragment in ECOSAR and DEREK for Windows needs to be evaluated and validated separately.

  4. Development and Validation of a Fatigue Assessment Scale for U.S. Construction Workers

    PubMed Central

    Zhang, Mingzong; Sparer, Emily H.; Murphy, Lauren A.; Dennerlein, Jack T.; Fang, Dongping; Katz, Jeffrey N.; Caban-Martinez, Alberto J.

    2015-01-01

    Objective To develop a fatigue assessment scale and test its reliability and validity for commercial construction workers. Methods Using a two-phased approach, we first identified items for the development of a Fatigue Assessment Scale for Construction Workers (FASCW) through review of existing scales in the scientific literature, key informant interviews (n=11) and focus groups (3 groups with 6 workers each) with construction workers. The second phase included assessment for the reliability, validity and sensitivity of the new scale using a repeated-measures study design with a convenience sample of construction workers (n=144). Results Phase one resulted in a 16-item preliminary scale that after factor analysis yielded a final 10-item scale with two sub-scales (“Lethargy” and “Bodily Ailment”).. During phase two, the FASCW and its subscales demonstrated satisfactory internal consistency (alpha coefficients were FASCW (0.91), Lethargy (0.86) and Bodily Ailment (0.84)) and acceptable test-retest reliability (Pearson Correlations Coefficients: 0.59–0.68; Intraclass Correlation Coefficients: 0.74–0.80). Correlation analysis substantiated concurrent and convergent validity. A discriminant analysis demonstrated that the FASCW differentiated between groups with arthritis status and different work hours. Conclusions The 10-item FASCW with good reliability and validity is an effective tool for assessing the severity of fatigue among construction workers. PMID:25603944

  5. The Validity of Conscientiousness Is Overestimated in the Prediction of Job Performance

    PubMed Central

    2015-01-01

    Introduction Sensitivity analyses refer to investigations of the degree to which the results of a meta-analysis remain stable when conditions of the data or the analysis change. To the extent that results remain stable, one can refer to them as robust. Sensitivity analyses are rarely conducted in the organizational science literature. Despite conscientiousness being a valued predictor in employment selection, sensitivity analyses have not been conducted with respect to meta-analytic estimates of the correlation (i.e., validity) between conscientiousness and job performance. Methods To address this deficiency, we reanalyzed the largest collection of conscientiousness validity data in the personnel selection literature and conducted a variety of sensitivity analyses. Results Publication bias analyses demonstrated that the validity of conscientiousness is moderately overestimated (by around 30%; a correlation difference of about .06). The misestimation of the validity appears to be due primarily to suppression of small effects sizes in the journal literature. These inflated validity estimates result in an overestimate of the dollar utility of personnel selection by millions of dollars and should be of considerable concern for organizations. Conclusion The fields of management and applied psychology seldom conduct sensitivity analyses. Through the use of sensitivity analyses, this paper documents that the existing literature overestimates the validity of conscientiousness in the prediction of job performance. Our data show that effect sizes from journal articles are largely responsible for this overestimation. PMID:26517553

  6. Challenges of forest landscape modeling - simulating large landscapes and validating results

    Treesearch

    Hong S. He; Jian Yang; Stephen R. Shifley; Frank R. Thompson

    2011-01-01

    Over the last 20 years, we have seen a rapid development in the field of forest landscape modeling, fueled by both technological and theoretical advances. Two fundamental challenges have persisted since the inception of FLMs: (1) balancing realistic simulation of ecological processes at broad spatial and temporal scales with computing capacity, and (2) validating...

  7. Rewarding Progress, Reducing Debt: Early Results from Ohio's Performance-Based Scholarship Demonstration for Low-Income Parents

    ERIC Educational Resources Information Center

    Cha, Paulette; Patel, Reshma

    2010-01-01

    This report presents early results from a rigorous evaluation of a performance-based scholarship program that was implemented at three community colleges in Ohio during the 2008-2009 academic year. The program in Ohio that is the subject of this report is part of MDRC's national Performance-Based Scholarship (PBS) Demonstration, which was launched…

  8. Validation of asthma recording in electronic health records: a systematic review

    PubMed Central

    Nissen, Francis; Quint, Jennifer K; Wilkinson, Samantha; Mullerova, Hana; Smeeth, Liam; Douglas, Ian J

    2017-01-01

    Objective To describe the methods used to validate asthma diagnoses in electronic health records and summarize the results of the validation studies. Background Electronic health records are increasingly being used for research on asthma to inform health services and health policy. Validation of the recording of asthma diagnoses in electronic health records is essential to use these databases for credible epidemiological asthma research. Methods We searched EMBASE and MEDLINE databases for studies that validated asthma diagnoses detected in electronic health records up to October 2016. Two reviewers independently assessed the full text against the predetermined inclusion criteria. Key data including author, year, data source, case definitions, reference standard, and validation statistics (including sensitivity, specificity, positive predictive value [PPV], and negative predictive value [NPV]) were summarized in two tables. Results Thirteen studies met the inclusion criteria. Most studies demonstrated a high validity using at least one case definition (PPV >80%). Ten studies used a manual validation as the reference standard; each had at least one case definition with a PPV of at least 63%, up to 100%. We also found two studies using a second independent database to validate asthma diagnoses. The PPVs of the best performing case definitions ranged from 46% to 58%. We found one study which used a questionnaire as the reference standard to validate a database case definition; the PPV of the case definition algorithm in this study was 89%. Conclusion Attaining high PPVs (>80%) is possible using each of the discussed validation methods. Identifying asthma cases in electronic health records is possible with high sensitivity, specificity or PPV, by combining multiple data sources, or by focusing on specific test measures. Studies testing a range of case definitions show wide variation in the validity of each definition, suggesting this may be important for obtaining

  9. Validation of Biofeedback Wearables for Photoplethysmographic Heart Rate Tracking

    PubMed Central

    Jo, Edward; Lewis, Kiana; Directo, Dean; Kim, Michael J.; Dolezal, Brett A.

    2016-01-01

    The purpose of this study was to examine the validity of HR measurements by two commercial-use activity trackers in comparison to ECG. Twenty-four healthy participants underwent the same 77-minute protocol during a single visit. Each participant completed an initial rest period of 15 minutes followed by 5 minute periods of each of the following activities: 60W and 120W cycling, walking, jogging, running, resisted arm raises, resisted lunges, and isometric plank. In between each exercise task was a 5-minute rest period. Each subject wore a Basis Peak (BPk) on one wrist and a Fitbit Charge HR (FB) on the opposite wrist. Criterion measurement of HR was administered by 12-lead ECG. Time synced data from each device and ECG were concurrently and electronically acquired throughout the entire 77-minute protocol. When examining data in aggregate, there was a strong correlation between BPk and ECG for HR (r = 0.92, p < 0.001) with a mean bias of -2.5 bpm (95% LoA 19.3, -24.4). The FB demonstrated a moderately strong correlation with ECG for HR (r = 0.83, p < 0.001) with an average mean bias of -8.8 bpm (95% LoA 24.2, -41.8). During physical efforts eliciting ECG HR > 116 bpm, the BPk demonstrated an r = 0.77 and mean bias = -4.9 bpm (95% LoA 21.3, -31.0) while the FB demonstrated an r = 0.58 and mean bias = -12.7 bpm (95% LoA 28.6, -54.0). The BPk satisfied validity criteria for HR monitors, however showed a marginal decline in accuracy with increasing physical effort (ECG HR > 116 bpm). The FB failed to satisfy validity criteria and demonstrated a substantial decrease in accuracy during higher exercise intensities. Key points Modern day wearable multi-sensor activity trackers incorporate reflective photoplethymography (PPG) for heart rate detection and monitoring at the dorsal wrist. This study examined the validity of two PPG-based activity trackers, the Basis Peak and Fitbit Charge HR. The Basis Peak performed with accuracy compared with ECG and results substantiate

  10. First Results from a Hardware-in-the-Loop Demonstration of Closed-Loop Autonomous Formation Flying

    NASA Technical Reports Server (NTRS)

    Gill, E.; Naasz, Bo; Ebinuma, T.

    2003-01-01

    A closed-loop system for the demonstration of formation flying technologies has been developed at NASA s Goddard Space Flight Center. Making use of a GPS signal simulator with a dual radio frequency outlet, the system includes two GPS space receivers as well as a powerful onboard navigation processor dedicated to the GPS-based guidance, navigation, and control of a satellite formation in real-time. The closed-loop system allows realistic simulations of autonomous formation flying scenarios, enabling research in the fields of tracking and orbit control strategies for a wide range of applications. A sample scenario has been set up where the autonomous transition of a satellite formation from an initial along-track separation of 800 m to a final distance of 100 m has been demonstrated. As a result, a typical control accuracy of about 5 m has been achieved which proves the applicability of autonomous formation flying techniques to formations of satellites as close as 50 m.

  11. Cold-end Subsystem Testing for the Fission Power System Technology Demonstration Unit

    NASA Technical Reports Server (NTRS)

    Briggs, Maxwell; Gibson, Marc; Ellis, David; Sanzi, James

    2013-01-01

    The Fission Power System (FPS) Technology Demonstration Unit (TDU) consists of a pumped sodium-potassium (NaK) loop that provides heat to a Stirling Power Conversion Unit (PCU), which converts some of that heat into electricity and rejects the waste heat to a pumped water loop. Each of the TDU subsystems is being tested independently prior to full system testing at the NASA Glenn Research Center. The pumped NaK loop is being tested at NASA Marshall Space Flight Center; the Stirling PCU and electrical controller are being tested by Sunpower Inc.; and the pumped water loop is being tested at Glenn. This paper describes cold-end subsystem setup and testing at Glenn. The TDU cold end has been assembled in Vacuum Facility 6 (VF 6) at Glenn, the same chamber that will be used for TDU testing. Cold-end testing in VF 6 will demonstrate functionality; validated cold-end fill, drain, and emergency backup systems; and generated pump performance and system pressure drop data used to validate models. In addition, a low-cost proof-of concept radiator has been built and tested at Glenn, validating the design and demonstrating the feasibility of using low-cost metal radiators as an alternative to high-cost composite radiators in an end-to-end TDU test.

  12. Cold-End Subsystem Testing for the Fission Power System Technology Demonstration Unit

    NASA Technical Reports Server (NTRS)

    Briggs, Mazwell; Gibson, Marc; Ellis, David; Sanzi, James

    2013-01-01

    The Fission Power System (FPS) Technology Demonstration Unit (TDU) consists of a pumped sodiumpotassium (NaK) loop that provides heat to a Stirling Power Conversion Unit (PCU), which converts some of that heat into electricity and rejects the waste heat to a pumped water loop. Each of the TDU subsystems is being tested independently prior to full system testing at the NASA Glenn Research Center. The pumped NaK loop is being tested at NASA Marshall Space Flight Center; the Stirling PCU and electrical controller are being tested by Sunpower Inc.; and the pumped water loop is being tested at Glenn. This paper describes cold-end subsystem setup and testing at Glenn. The TDU cold end has been assembled in Vacuum Facility 6 (VF 6) at Glenn, the same chamber that will be used for TDU testing. Cold-end testing in VF 6 will demonstrate functionality; validated coldend fill, drain, and emergency backup systems; and generated pump performance and system pressure drop data used to validate models. In addition, a low-cost proof-of concept radiator has been built and tested at Glenn, validating the design and demonstrating the feasibility of using low-cost metal radiators as an alternative to highcost composite radiators in an end-to-end TDU test.

  13. Validation of the Japanese version of the Pediatric Quality of Life Inventory (PedsQL) Cancer Module.

    PubMed

    Tsuji, Naoko; Kakee, Naoko; Ishida, Yasushi; Asami, Keiko; Tabuchi, Ken; Nakadate, Hisaya; Iwai, Tsuyako; Maeda, Miho; Okamura, Jun; Kazama, Takuro; Terao, Yoko; Ohyama, Wataru; Yuza, Yuki; Kaneko, Takashi; Manabe, Atsushi; Kobayashi, Kyoko; Kamibeppu, Kiyoko; Matsushima, Eisuke

    2011-04-10

    demonstrated significantly higher scores than those on treatment. The results demonstrate the reliability and validity of the Japanese version of the PedsQL Cancer Module among Japanese children.

  14. Bent Creek demonstration program

    Treesearch

    Erik C. Berg

    1997-01-01

    Bent Creek Research and Demonstration Forest scientists have transferred the results of research on the ecology and management of Southern Appalachian hardwoods since 1925. Since 1989, a full-time technology transfer specialist has led demonstration efforts. The demonstration program was designed to quickly transfer research results to interested users and to free...

  15. Bent Creek demonstration program

    Treesearch

    Erik C. Berg

    1997-01-01

    Bent Creek Research and Demonstration Forest scientists have transferred the results of research on the ecology and management of Southern Appalachian hardwoods since 1925. Since 1989, a full-time technology transfer specialist has led demonstration efforts. The demonstration program was designed to quickly transfer research results to interested users, and free-up...

  16. Field demonstration of polymer-amended in situ chemical oxidation (PA-ISCO)

    NASA Astrophysics Data System (ADS)

    Silva, Jeff A. K.; Crimi, Michelle; Palaia, Thomas; Ko, Saebom; Davenport, Sean

    2017-04-01

    The methods and results of the first field-scale demonstration of polymer-amended in situ chemical oxidation (PA-ISCO) are presented. The demonstration took place at MCB CAMLEJ (Marine Corps Base, Camp Lejeune) Operable Unit (OU) 15, Site 88, in Camp Lejeune, North Carolina between October and December 2010. PA-ISCO was developed as an alternative treatment approach that utilizes viscosity-modified fluids to improve the in situ delivery and distribution (i.e. sweep-efficiency) of chemical oxidants within texturally heterogeneous contaminated aquifers. The enhanced viscosity of the fluid mitigates the effects of preferential flows, improving sweep-efficiency and enhancing the subsurface contact between the injected oxidant and the target contamination within the treatment zone. The PA-ISCO fluid formulation used in this demonstration included sodium permanganate as oxidant, xanthan gum biopolymer as a shear-thinning viscosifier, and sodium hexametaphosphate (SHMP) as an anti-coagulant. It was the goal of this demonstration to validate the utility of PA-ISCO within a heterogeneous aquifer. An approximate 100% improvement in sweep-efficiency was achieved for the PA-ISCO fluid, as compared to a permanganate-only injection within an adjacent control plot.

  17. Assessing teachers' positive psychological functioning at work: Development and validation of the Teacher Subjective Wellbeing Questionnaire.

    PubMed

    Renshaw, Tyler L; Long, Anna C J; Cook, Clayton R

    2015-06-01

    This study reports on the initial development and validation of the Teacher Subjective Wellbeing Questionnaire (TSWQ) with 2 samples of educators-a general sample of 185 elementary and middle school teachers, and a target sample of 21 elementary school teachers experiencing classroom management challenges. The TSWQ is an 8-item self-report instrument for assessing teachers' subjective wellbeing, which is operationalized via subscales measuring school connectedness and teaching efficacy. The conceptualization and development processes underlying the TSWQ are described, and results from a series of preliminary psychometric and exploratory analyses are reported to establish initial construct validity. Findings indicated that the TSWQ was characterized by 2 conceptually sound latent factors, that both subscales and the composite scale demonstrated strong internal consistency, and that all scales demonstrated convergent validity with self-reported school supports and divergent validity with self-reported stress and emotional burnout. Furthermore, results indicated that TSWQ scores did not differ according to teachers' school level (i.e., elementary vs. middle), but that they did differ according to unique school environment (e.g., 1 middle school vs. another middle school) and teacher stressors (i.e., general teachers vs. teachers experiencing classroom management challenges). Results also indicated that, for teachers experiencing classroom challenges, the TSWQ had strong short-term predictive validity for psychological distress, accounting for approximately half of the variance in teacher stress and emotional burnout. Implications for theory, research, and the practice of school psychology are discussed. (c) 2015 APA, all rights reserved).

  18. 40 CFR 63.5725 - What are the requirements for monitoring and demonstrating continuous compliance?

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... Pollutants for Boat Manufacturing Demonstrating Compliance for Open Molding Operations Controlled by Add-on... successive cycles of operation to have a valid hour of data. (2) You must have valid data from at least 90... parameter monitoring system and collect emission capture system and add-on control device parameter data at...

  19. 40 CFR 63.5725 - What are the requirements for monitoring and demonstrating continuous compliance?

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... Pollutants for Boat Manufacturing Demonstrating Compliance for Open Molding Operations Controlled by Add-on... successive cycles of operation to have a valid hour of data. (2) You must have valid data from at least 90... parameter monitoring system and collect emission capture system and add-on control device parameter data at...

  20. Experimental Demonstration of Technologies for Autonomous On-Orbit Robotic Assembly

    NASA Technical Reports Server (NTRS)

    LeMaster, Edward A.; Schaechter, David B.; Carrington, Connie K.

    2006-01-01

    The Modular Reconfigurable High Energy (MRHE) program aimed to develop technologies for the automated assembly and deployment of large-scale space structures and aggregate spacecraft. Part of the project involved creation of a terrestrial robotic testbed for validation and demonstration of these technologies and for the support of future development activities. This testbed was completed in 2005, and was thereafter used to demonstrate automated rendezvous, docking, and self-assembly tasks between a group of three modular robotic spacecraft emulators. This paper discusses the rationale for the MRHE project, describes the testbed capabilities, and presents the MRHE assembly demonstration sequence.

  1. Validation of model-based deformation correction in image-guided liver surgery via tracked intraoperative ultrasound: preliminary method and results

    NASA Astrophysics Data System (ADS)

    Clements, Logan W.; Collins, Jarrod A.; Wu, Yifei; Simpson, Amber L.; Jarnagin, William R.; Miga, Michael I.

    2015-03-01

    Soft tissue deformation represents a significant error source in current surgical navigation systems used for open hepatic procedures. While numerous algorithms have been proposed to rectify the tissue deformation that is encountered during open liver surgery, clinical validation of the proposed methods has been limited to surface based metrics and sub-surface validation has largely been performed via phantom experiments. Tracked intraoperative ultrasound (iUS) provides a means to digitize sub-surface anatomical landmarks during clinical procedures. The proposed method involves the validation of a deformation correction algorithm for open hepatic image-guided surgery systems via sub-surface targets digitized with tracked iUS. Intraoperative surface digitizations were acquired via a laser range scanner and an optically tracked stylus for the purposes of computing the physical-to-image space registration within the guidance system and for use in retrospective deformation correction. Upon completion of surface digitization, the organ was interrogated with a tracked iUS transducer where the iUS images and corresponding tracked locations were recorded. After the procedure, the clinician reviewed the iUS images to delineate contours of anatomical target features for use in the validation procedure. Mean closest point distances between the feature contours delineated in the iUS images and corresponding 3-D anatomical model generated from the preoperative tomograms were computed to quantify the extent to which the deformation correction algorithm improved registration accuracy. The preliminary results for two patients indicate that the deformation correction method resulted in a reduction in target error of approximately 50%.

  2. JaCVAM-organized international validation study of the in vivo rodent alkaline comet assay for the detection of genotoxic carcinogens: I. Summary of pre-validation study results.

    PubMed

    Uno, Yoshifumi; Kojima, Hajime; Omori, Takashi; Corvi, Raffaella; Honma, Masamistu; Schechtman, Leonard M; Tice, Raymond R; Burlinson, Brian; Escobar, Patricia A; Kraynak, Andrew R; Nakagawa, Yuzuki; Nakajima, Madoka; Pant, Kamala; Asano, Norihide; Lovell, David; Morita, Takeshi; Ohno, Yasuo; Hayashi, Makoto

    2015-07-01

    The in vivo rodent alkaline comet assay (comet assay) is used internationally to investigate the in vivo genotoxic potential of test chemicals. This assay, however, has not previously been formally validated. The Japanese Center for the Validation of Alternative Methods (JaCVAM), with the cooperation of the U.S. NTP Interagency Center for the Evaluation of Alternative Toxicological Methods (NICEATM)/the Interagency Coordinating Committee on the Validation of Alternative Methods (ICCVAM), the European Centre for the Validation of Alternative Methods (ECVAM), and the Japanese Environmental Mutagen Society/Mammalian Mutagenesis Study Group (JEMS/MMS), organized an international validation study to evaluate the reliability and relevance of the assay for identifying genotoxic carcinogens, using liver and stomach as target organs. The ultimate goal of this validation effort was to establish an Organisation for Economic Co-operation and Development (OECD) test guideline. The purpose of the pre-validation studies (i.e., Phase 1 through 3), conducted in four or five laboratories with extensive comet assay experience, was to optimize the protocol to be used during the definitive validation study. Copyright © 2015 Elsevier B.V. All rights reserved.

  3. Evaluating the Content Validity of Multistage-Adaptive Tests

    ERIC Educational Resources Information Center

    Crotts, Katrina; Sireci, Stephen G.; Zenisky, April

    2012-01-01

    Validity evidence based on test content is important for educational tests to demonstrate the degree to which they fulfill their purposes. Most content validity studies involve subject matter experts (SMEs) who rate items that comprise a test form. In computerized-adaptive testing, examinees take different sets of items and test "forms"…

  4. Validation of the revised Mystical Experience Questionnaire in experimental sessions with psilocybin.

    PubMed

    Barrett, Frederick S; Johnson, Matthew W; Griffiths, Roland R

    2015-11-01

    The 30-item revised Mystical Experience Questionnaire (MEQ30) was previously developed within an online survey of mystical-type experiences occasioned by psilocybin-containing mushrooms. The rated experiences occurred on average eight years before completion of the questionnaire. The current paper validates the MEQ30 using data from experimental studies with controlled doses of psilocybin. Data were pooled and analyzed from five laboratory experiments in which participants (n=184) received a moderate to high oral dose of psilocybin (at least 20 mg/70 kg). Results of confirmatory factor analysis demonstrate the reliability and internal validity of the MEQ30. Structural equation models demonstrate the external and convergent validity of the MEQ30 by showing that latent variable scores on the MEQ30 positively predict persisting change in attitudes, behavior, and well-being attributed to experiences with psilocybin while controlling for the contribution of the participant-rated intensity of drug effects. These findings support the use of the MEQ30 as an efficient measure of individual mystical experiences. A method to score a "complete mystical experience" that was used in previous versions of the mystical experience questionnaire is validated in the MEQ30, and a stand-alone version of the MEQ30 is provided for use in future research. © The Author(s) 2015.

  5. Validation of the revised Mystical Experience Questionnaire in experimental sessions with psilocybin

    PubMed Central

    Barrett, Frederick S; Johnson, Matthew W; Griffiths, Roland R

    2016-01-01

    The 30-item revised Mystical Experience Questionnaire (MEQ30) was previously developed within an online survey of mystical-type experiences occasioned by psilocybin-containing mushrooms. The rated experiences occurred on average eight years before completion of the questionnaire. The current paper validates the MEQ30 using data from experimental studies with controlled doses of psilocybin. Data were pooled and analyzed from five laboratory experiments in which participants (n=184) received a moderate to high oral dose of psilocybin (at least 20 mg/70 kg). Results of confirmatory factor analysis demonstrate the reliability and internal validity of the MEQ30. Structural equation models demonstrate the external and convergent validity of the MEQ30 by showing that latent variable scores on the MEQ30 positively predict persisting change in attitudes, behavior, and well-being attributed to experiences with psilocybin while controlling for the contribution of the participant-rated intensity of drug effects. These findings support the use of the MEQ30 as an efficient measure of individual mystical experiences. A method to score a “complete mystical experience” that was used in previous versions of the mystical experience questionnaire is validated in the MEQ30, and a stand-alone version of the MEQ30 is provided for use in future research. PMID:26442957

  6. The Development and Validation of the Rational and Intuitive Decision Styles Scale.

    PubMed

    Hamilton, Katherine; Shih, Shin-I; Mohammed, Susan

    2016-01-01

    Decision styles reflect the typical manner by which individuals make decisions. The purpose of this research was to develop and validate a decision style scale that addresses conceptual and psychometric problems with current measures. The resulting 10-item scale captures a broad range of the rational and intuitive styles construct domain. Results from 5 independent samples provide initial support for the dimensionality and reliability of the new scale, as demonstrated by a clear factor structure and high internal consistency. In addition, our results show evidence of convergent and discriminant validity through expected patterns of correlations across decision-making individual differences and the International Personality Item Pool (IPIP) Big Five traits. Research domains that would benefit from incorporating the concept of decision styles are discussed.

  7. Effort, symptom validity testing, performance validity testing and traumatic brain injury.

    PubMed

    Bigler, Erin D

    2014-01-01

    To understand the neurocognitive effects of brain injury, valid neuropsychological test findings are paramount. This review examines the research on what has been referred to a symptom validity testing (SVT). Above a designated cut-score signifies a 'passing' SVT performance which is likely the best indicator of valid neuropsychological test findings. Likewise, substantially below cut-point performance that nears chance or is at chance signifies invalid test performance. Significantly below chance is the sine qua non neuropsychological indicator for malingering. However, the interpretative problems with SVT performance below the cut-point yet far above chance are substantial, as pointed out in this review. This intermediate, border-zone performance on SVT measures is where substantial interpretative challenges exist. Case studies are used to highlight the many areas where additional research is needed. Historical perspectives are reviewed along with the neurobiology of effort. Reasons why performance validity testing (PVT) may be better than the SVT term are reviewed. Advances in neuroimaging techniques may be key in better understanding the meaning of border zone SVT failure. The review demonstrates the problems with rigidity in interpretation with established cut-scores. A better understanding of how certain types of neurological, neuropsychiatric and/or even test conditions may affect SVT performance is needed.

  8. Demonstration of the coast-down technique for determining train resistances

    NASA Technical Reports Server (NTRS)

    Dayman, B.

    1983-01-01

    Full-scale measurement or validation of the various factors of train running resistance is an essential step in decreasing train energy consumption. Such a measurement capability would enable railroads to evaluate the cost benefits of operational and train consistent configuration changes, and new vehicle and truck designs for decreasing aerodynamic drag and rolling resistance. A decrease in the rolling resistance affects more than just a decrease in energy consumption; it also will result in decreased mechanical wear, hence less wheel and rail maintenance and replacement costs. A demonstration of a simple coast-down technique (based on computer-reduction of distance history) was accomplished using specially configured trains on main line rail provided by the Atchison, Topeka and Sante Fe Railway Co. This demonstration test shows that this distance-history coast-down technique for trains is easy to execute in the field. The total running resistance history was accurately determined and subsequently separated into rolling resistance (mechanical friction) and aerodynamic drag.

  9. Brazilian validation of the Alberta Infant Motor Scale.

    PubMed

    Valentini, Nadia Cristina; Saccani, Raquel

    2012-03-01

    The Alberta Infant Motor Scale (AIMS) is a well-known motor assessment tool used to identify potential delays in infants' motor development. Although Brazilian researchers and practitioners have used the AIMS in laboratories and clinical settings, its translation to Portuguese and validation for the Brazilian population is yet to be investigated. This study aimed to translate and validate all AIMS items with respect to internal consistency and content, criterion, and construct validity. A cross-sectional and longitudinal design was used. A cross-cultural translation was used to generate a Brazilian-Portuguese version of the AIMS. In addition, a validation process was conducted involving 22 professionals and 766 Brazilian infants (aged 0-18 months). The results demonstrated language clarity and internal consistency for the motor criteria (motor development score, α=.90; prone, α=.85; supine, α=.92; sitting, α=.84; and standing, α=.86). The analysis also revealed high discriminative power to identify typical and atypical development (motor development score, P<.001; percentile, P=.04; classification criterion, χ(2)=6.03; P=.05). Temporal stability (P=.07) (rho=.85, P<.001) was observed, and predictive power (P<.001) was limited to the group of infants aged from 3 months to 9 months. Limited predictive validity was observed, which may have been due to the restricted time that the groups were followed longitudinally. In sum, the translated version of AIMS presented adequate validity and reliability.

  10. Mental State Assessment and Validation Using Personalized Physiological Biometrics

    PubMed Central

    Patel, Aashish N.; Howard, Michael D.; Roach, Shane M.; Jones, Aaron P.; Bryant, Natalie B.; Robinson, Charles S. H.; Clark, Vincent P.; Pilly, Praveen K.

    2018-01-01

    Mental state monitoring is a critical component of current and future human-machine interfaces, including semi-autonomous driving and flying, air traffic control, decision aids, training systems, and will soon be integrated into ubiquitous products like cell phones and laptops. Current mental state assessment approaches supply quantitative measures, but their only frame of reference is generic population-level ranges. What is needed are physiological biometrics that are validated in the context of task performance of individuals. Using curated intake experiments, we are able to generate personalized models of three key biometrics as useful indicators of mental state; namely, mental fatigue, stress, and attention. We demonstrate improvements to existing approaches through the introduction of new features. Furthermore, addressing the current limitations in assessing the efficacy of biometrics for individual subjects, we propose and employ a multi-level validation scheme for the biometric models by means of k-fold cross-validation for discrete classification and regression testing for continuous prediction. The paper not only provides a unified pipeline for extracting a comprehensive mental state evaluation from a parsimonious set of sensors (only EEG and ECG), but also demonstrates the use of validation techniques in the absence of empirical data. Furthermore, as an example of the application of these models to novel situations, we evaluate the significance of correlations of personalized biometrics to the dynamic fluctuations of accuracy and reaction time on an unrelated threat detection task using a permutation test. Our results provide a path toward integrating biometrics into augmented human-machine interfaces in a judicious way that can help to maximize task performance.

  11. Mental State Assessment and Validation Using Personalized Physiological Biometrics.

    PubMed

    Patel, Aashish N; Howard, Michael D; Roach, Shane M; Jones, Aaron P; Bryant, Natalie B; Robinson, Charles S H; Clark, Vincent P; Pilly, Praveen K

    2018-01-01

    Mental state monitoring is a critical component of current and future human-machine interfaces, including semi-autonomous driving and flying, air traffic control, decision aids, training systems, and will soon be integrated into ubiquitous products like cell phones and laptops. Current mental state assessment approaches supply quantitative measures, but their only frame of reference is generic population-level ranges. What is needed are physiological biometrics that are validated in the context of task performance of individuals. Using curated intake experiments, we are able to generate personalized models of three key biometrics as useful indicators of mental state; namely, mental fatigue, stress, and attention. We demonstrate improvements to existing approaches through the introduction of new features. Furthermore, addressing the current limitations in assessing the efficacy of biometrics for individual subjects, we propose and employ a multi-level validation scheme for the biometric models by means of k -fold cross-validation for discrete classification and regression testing for continuous prediction. The paper not only provides a unified pipeline for extracting a comprehensive mental state evaluation from a parsimonious set of sensors (only EEG and ECG), but also demonstrates the use of validation techniques in the absence of empirical data. Furthermore, as an example of the application of these models to novel situations, we evaluate the significance of correlations of personalized biometrics to the dynamic fluctuations of accuracy and reaction time on an unrelated threat detection task using a permutation test. Our results provide a path toward integrating biometrics into augmented human-machine interfaces in a judicious way that can help to maximize task performance.

  12. Californian demonstration and validation of automated agricultural field extraction from multi-temporal Landsat data

    NASA Astrophysics Data System (ADS)

    Yan, L.; Roy, D. P.

    2013-12-01

    The spatial distribution of agricultural fields is a fundamental description of rural landscapes and the location and extent of fields is important to establish the area of land utilized for agricultural yield prediction, resource allocation, and for economic planning. To date, field objects have not been extracted from satellite data over large areas because of computational constraints and because consistently processed appropriate resolution data have not been available or affordable. We present a fully automated computational methodology to extract agricultural fields from 30m Web Enabled Landsat data (WELD) time series and results for approximately 250,000 square kilometers (eleven 150 x 150 km WELD tiles) encompassing all the major agricultural areas of California. The extracted fields, including rectangular, circular, and irregularly shaped fields, are evaluated by comparison with manually interpreted Landsat field objects. Validation results are presented in terms of standard confusion matrix accuracy measures and also the degree of field object over-segmentation, under-segmentation, fragmentation and shape distortion. The apparent success of the presented field extraction methodology is due to several factors. First, the use of multi-temporal Landsat data, as opposed to single Landsat acquisitions, that enables crop rotations and inter-annual variability in the state of the vegetation to be accommodated for and provides more opportunities for cloud-free, non-missing and atmospherically uncontaminated surface observations. Second, the adoption of an object based approach, namely the variational region-based geometric active contour method that enables robust segmentation with only a small number of parameters and that requires no training data collection. Third, the use of a watershed algorithm to decompose connected segments belonging to multiple fields into coherent isolated field segments and a geometry based algorithm to detect and associate parts of

  13. Ego-Dissolution and Psychedelics: Validation of the Ego-Dissolution Inventory (EDI)

    PubMed Central

    Nour, Matthew M.; Evans, Lisa; Nutt, David; Carhart-Harris, Robin L.

    2016-01-01

    Aims: The experience of a compromised sense of “self”, termed ego-dissolution, is a key feature of the psychedelic experience. This study aimed to validate the Ego-Dissolution Inventory (EDI), a new 8-item self-report scale designed to measure ego-dissolution. Additionally, we aimed to investigate the specificity of the relationship between psychedelics and ego-dissolution. Method: Sixteen items relating to altered ego-consciousness were included in an internet questionnaire; eight relating to the experience of ego-dissolution (comprising the EDI), and eight relating to the antithetical experience of increased self-assuredness, termed ego-inflation. Items were rated using a visual analog scale. Participants answered the questionnaire for experiences with classical psychedelic drugs, cocaine and/or alcohol. They also answered the seven questions from the Mystical Experiences Questionnaire (MEQ) relating to the experience of unity with one’s surroundings. Results: Six hundred and ninety-one participants completed the questionnaire, providing data for 1828 drug experiences (1043 psychedelics, 377 cocaine, 408 alcohol). Exploratory factor analysis demonstrated that the eight EDI items loaded exclusively onto a single common factor, which was orthogonal to a second factor comprised of the items relating to ego-inflation (rho = −0.110), demonstrating discriminant validity. The EDI correlated strongly with the MEQ-derived measure of unitive experience (rho = 0.735), demonstrating convergent validity. EDI internal consistency was excellent (Cronbach’s alpha 0.93). Three analyses confirmed the specificity of ego-dissolution for experiences occasioned by psychedelic drugs. Firstly, EDI score correlated with drug-dose for psychedelic drugs (rho = 0.371), but not for cocaine (rho = 0.115) or alcohol (rho = −0.055). Secondly, the linear regression line relating the subjective intensity of the experience to ego-dissolution was significantly steeper for psychedelics

  14. "La Clave Profesional": Validation of a Vocational Guidance Instrument

    ERIC Educational Resources Information Center

    Mudarra, Maria J.; Lázaro Martínez, Ángel

    2014-01-01

    Introduction: The current study demonstrates empirical and cultural validity of "La Clave Profesional" (Spanish adaptation of Career Key, Jones's test based Holland's RIASEC model). The process of providing validity evidence also includes a reflection on personal and career development and examines the relationahsips between RIASEC…

  15. Reliability and validity of the Brief Pain Inventory in individuals with chronic obstructive pulmonary disease.

    PubMed

    Chen, Y-W; HajGhanbari, B; Road, J D; Coxson, H O; Camp, P G; Reid, W D

    2018-06-08

    Pain is prevalent in chronic obstructive pulmonary disease (COPD) and the Brief Pain Inventory (BPI) appears to be a feasible questionnaire to assess this symptom. However, the reliability and validity of the BPI have not been determined in individuals with COPD. This study aimed to determine the internal consistency, test-retest reliability and validity (construct, convergent, divergent and discriminant) of the BPI in individuals with COPD. In order to examine the test-retest reliability, individuals with COPD were recruited from pulmonary rehabilitation programmes to complete the BPI twice 1 week apart. In order to investigate validity, de-identified data was retrieved from two previous studies, including forced expiratory volume in 1-s, age, sex and data from four questionnaires: the BPI, short-form McGill Pain Questionnaire (SF-MPQ), 36-Item Short Form Survey (SF-36) and Community Health Activities Model Program for Seniors (CHAMPS) questionnaire. In total, 123 participants were included in the analyses (eligible data were retrieved from 86 participants and additional 37 participants were recruited). The BPI demonstrated excellent internal consistency and test-retest reliability. It also showed convergent validity with the SF-MPQ and divergent validity with the SF-36. The factor analysis yielded two factors of the BPI, which demonstrated that the two domains of the BPI measure the intended constructs. The BPI can also discriminate pain levels among COPD patients with varied levels of quality of life (SF-36) and physical activity (CHAMPS). The BPI is a reliable and valid pain questionnaire that can be used to evaluate pain in COPD. This study formally established the reliability and validity of the BPI in individuals with COPD, which have not been determined in this patient group. The results of this study provide strong evidence that assessment results from this pain questionnaire are reliable and valid. © 2018 European Pain Federation - EFIC®.

  16. Clinical validation of an epigenetic assay to predict negative histopathological results in repeat prostate biopsies.

    PubMed

    Partin, Alan W; Van Neste, Leander; Klein, Eric A; Marks, Leonard S; Gee, Jason R; Troyer, Dean A; Rieger-Christ, Kimberly; Jones, J Stephen; Magi-Galluzzi, Cristina; Mangold, Leslie A; Trock, Bruce J; Lance, Raymond S; Bigley, Joseph W; Van Criekinge, Wim; Epstein, Jonathan I

    2014-10-01

    The DOCUMENT multicenter trial in the United States validated the performance of an epigenetic test as an independent predictor of prostate cancer risk to guide decision making for repeat biopsy. Confirming an increased negative predictive value could help avoid unnecessary repeat biopsies. We evaluated the archived, cancer negative prostate biopsy core tissue samples of 350 subjects from a total of 5 urological centers in the United States. All subjects underwent repeat biopsy within 24 months with a negative (controls) or positive (cases) histopathological result. Centralized blinded pathology evaluation of the 2 biopsy series was performed in all available subjects from each site. Biopsies were epigenetically profiled for GSTP1, APC and RASSF1 relative to the ACTB reference gene using quantitative methylation specific polymerase chain reaction. Predetermined analytical marker cutoffs were used to determine assay performance. Multivariate logistic regression was used to evaluate all risk factors. The epigenetic assay resulted in a negative predictive value of 88% (95% CI 85-91). In multivariate models correcting for age, prostate specific antigen, digital rectal examination, first biopsy histopathological characteristics and race the test proved to be the most significant independent predictor of patient outcome (OR 2.69, 95% CI 1.60-4.51). The DOCUMENT study validated that the epigenetic assay was a significant, independent predictor of prostate cancer detection in a repeat biopsy collected an average of 13 months after an initial negative result. Due to its 88% negative predictive value adding this epigenetic assay to other known risk factors may help decrease unnecessary repeat prostate biopsies. Copyright © 2014 American Urological Association Education and Research, Inc. Published by Elsevier Inc. All rights reserved.

  17. Development and Validation of the Food Liking Questionnaire in a French-Canadian Population

    PubMed Central

    Carbonneau, Elise; Bradette-Laplante, Maude; Lamarche, Benoît; Provencher, Véronique; Bégin, Catherine; Robitaille, Julie; Desroches, Sophie; Corneau, Louise; Lemieux, Simone

    2017-01-01

    The purpose of this study was to develop and validate a questionnaire assessing food liking in a French-Canadian population. A questionnaire was developed, in which participants were asked to rate their degree of liking of 50 food items. An expert panel evaluated the content validity. For the validation study, 150 men and women completed the questionnaire twice. An Exploratory Factor Analysis (EFA) was performed to assess the number of subscales of the questionnaire. Internal consistency and test-retest reliability of the subscales were evaluated. Concurrent validity was assessed through correlations between liking scores and self-reported frequencies of consumption. Comments from the experts led to changes in the list of foods included in the questionnaire. The EFA revealed a two-factor structure for the questionnaire (i.e., savory and sweet foods) and led to the removal of nine items, resulting in a 32-item questionnaire. The two subscales revealed good internal consistency (Cronbach alphas: 0.85 and 0.89) and test-retest reliability (p = 0.84 and 0.86). The questionnaire demonstrated adequate concurrent validity, with moderate correlations between food liking and self-reported frequency of consumption (r = 0.19–0.39, ps < 0.05). This new Food Liking Questionnaire assessing liking of a variety of savory and sweet foods demonstrated good psychometric properties in every validation step. This questionnaire will be useful to explore the role of food liking and its interactions with other factors in predicting eating behaviors and energy intake. PMID:29292754

  18. Development and Validation of the Food Liking Questionnaire in a French-Canadian Population.

    PubMed

    Carbonneau, Elise; Bradette-Laplante, Maude; Lamarche, Benoît; Provencher, Véronique; Bégin, Catherine; Robitaille, Julie; Desroches, Sophie; Vohl, Marie-Claude; Corneau, Louise; Lemieux, Simone

    2017-12-08

    The purpose of this study was to develop and validate a questionnaire assessing food liking in a French-Canadian population. A questionnaire was developed, in which participants were asked to rate their degree of liking of 50 food items. An expert panel evaluated the content validity. For the validation study, 150 men and women completed the questionnaire twice. An Exploratory Factor Analysis (EFA) was performed to assess the number of subscales of the questionnaire. Internal consistency and test-retest reliability of the subscales were evaluated. Concurrent validity was assessed through correlations between liking scores and self-reported frequencies of consumption. Comments from the experts led to changes in the list of foods included in the questionnaire. The EFA revealed a two-factor structure for the questionnaire (i.e., savory and sweet foods) and led to the removal of nine items, resulting in a 32-item questionnaire. The two subscales revealed good internal consistency (Cronbach alphas: 0.85 and 0.89) and test-retest reliability ( p = 0.84 and 0.86). The questionnaire demonstrated adequate concurrent validity, with moderate correlations between food liking and self-reported frequency of consumption ( r = 0.19-0.39, p s < 0.05). This new Food Liking Questionnaire assessing liking of a variety of savory and sweet foods demonstrated good psychometric properties in every validation step. This questionnaire will be useful to explore the role of food liking and its interactions with other factors in predicting eating behaviors and energy intake.

  19. SCIAMACHY validation by aircraft remote measurements: design, execution, and first results of the SCIA-VALUE mission

    NASA Astrophysics Data System (ADS)

    Fix, A.; Ehret, G.; Flentje, H.; Poberaj, G.; Gottwald, M.; Finkenzeller, H.; Bremer, H.; Bruns, M.; Burrows, J. P.; Kleinböhl, A.; Küllmann, H.; Kuttippurath, J.; Richter, A.; Wang, P.; Heue, K.-P.; Platt, U.; Wagner, T.

    2004-12-01

    For the first time three different remote sensing instruments - a sub-millimeter radiometer, a differential optical absorption spectrometer in the UV-visible spectral range, and a lidar - were deployed aboard DLR's meteorological research aircraft Falcon 20 to validate a large number of SCIAMACHY level 2 and off-line data products such as O3, NO2, N2O, BrO, OClO, H2O, aerosols, and clouds. Within two main validation campaigns of the SCIA-VALUE mission (SCIAMACHY VALidation and Utilization Experiment) extended latitudinal cross-sections stretching from polar regions to the tropics as well as longitudinal cross sections at polar latitudes at about 70° N and the equator have been generated. This contribution gives an overview over the campaigns performed and reports on the observation strategy for achieving the validation goals. We also emphasize the synergetic use of the novel set of aircraft instrumentation and the usefulness of this innovative suite of remote sensing instruments for satellite validation.

  20. Translation and validation of the Canadian diabetes risk assessment questionnaire in China.

    PubMed

    Guo, Jia; Shi, Zhengkun; Chen, Jyu-Lin; Dixon, Jane K; Wiley, James; Parry, Monica

    2018-01-01

    To adapt the Canadian Diabetes Risk Assessment Questionnaire for the Chinese population and to evaluate its psychometric properties. A cross-sectional study was conducted with a convenience sample of 194 individuals aged 35-74 years from October 2014 to April 2015. The Canadian Diabetes Risk Assessment Questionnaire was adapted and translated for the Chinese population. Test-retest reliability was conducted to measure stability. Criterion and convergent validity of the adapted questionnaire were assessed using 2-hr 75 g oral glucose tolerance tests and the Finnish Diabetes Risk Scores, respectively. Sensitivity and specificity were evaluated to establish its predictive validity. The test-retest reliability was 0.988. Adequate validity of the adapted questionnaire was demonstrated by positive correlations found between the scores and 2-hr 75 g oral glucose tolerance tests (r = .343, p < .001) and with the Finnish Diabetes Risk Scores (r = .738, p < .001). The area under receiver operating characteristic curve was 0.705 (95% CI .632, .778), demonstrating moderate diagnostic value at a cutoff score of 30. The sensitivity was 73%, with a positive predictive value of 57% and negative predictive value of 78%. Our results provided evidence supporting the translation consistency, content validity, convergent validity, criterion validity, sensitivity, and specificity of the translated Canadian Diabetes Risk Assessment Questionnaire with minor modifications. This paper provides clinical, practical, and methodological information on how to adapt a diabetes risk calculator between cultures for public health nurses. © 2017 Wiley Periodicals, Inc.

  1. Development and validation of the Self-Esteem And Relationship (SEAR) questionnaire in erectile dysfunction.

    PubMed

    Cappelleri, J C; Althof, S E; Siegel, R L; Shpilsky, A; Bell, S S; Duttagupta, S

    2004-02-01

    Development and validation of a patient-reported measure of psychosocial variables in men with erectile dysfunction (ED) is described. Literature review, focus groups, and medical specialists identified 86 potential items. Redundant, ambiguous, or low item-to-total correlation items were removed. Data from 98 men reporting diagnosed ED and 94 controls assisted in final item selection and psychometric evaluation. Treatment responsiveness was evaluated in 93 men with ED in a 10-week open-label trial of sildenafil citrate (Viagra). The 14 chosen items resolved into two domains: Sexual Relationship (eight items) and Confidence (six items), the latter comprising Self-Esteem (four items) and Overall Relationship (two items) subscales. The resulting Self-Esteem And Relationship (SEAR) questionnaire demonstrated validity and reliability. The intervention study demonstrated responsiveness to beneficial treatment with significant improvement in scores (P=0.0001). The SEAR questionnaire possesses strong psychometric properties that support its validity and reliability for measuring sexual relationship, confidence, and particularly self-esteem.

  2. Preliminary Face and Construct Validation Study of a Virtual Basic Laparoscopic Skill Trainer

    PubMed Central

    Sankaranarayanan, Ganesh; Lin, Henry; Arikatla, Venkata S.; Mulcare, Maureen; Zhang, Likun; Derevianko, Alexandre; Lim, Robert; Fobert, David; Cao, Caroline; Schwaitzberg, Steven D.; Jones, Daniel B.

    2010-01-01

    Abstract Background The Virtual Basic Laparoscopic Skill Trainer (VBLaST™) is a developing virtual-reality–based surgical skill training system that incorporates several of the tasks of the Fundamentals of Laparoscopic Surgery (FLS) training system. This study aimed to evaluate the face and construct validity of the VBLaST™ system. Materials and Methods Thirty-nine subjects were voluntarily recruited at the Beth Israel Deaconess Medical Center (Boston, MA) and classified into two groups: experts (PGY 5, fellow and practicing surgeons) and novice (PGY 1–4). They were then asked to perform three FLS tasks, consisting of peg transfer, pattern cutting, and endoloop, on both the VBLaST and FLS systems. The VBLaST performance scores were automatically computed, while the FLS scores were rated by a trained evaluator. Face validity was assessed using a 5-point Likert scale, varying from not realistic/useful (1) to very realistic/useful (5). Results Face-validity scores showed that the VBLaST system was significantly realistic in portraying the three FLS tasks (3.95 ± 0.909), as well as the reality in trocar placement and tool movements (3.67 ± 0.874). Construct-validity results show that VBLaST was able to differentiate between the expert and novice group (P = 0.015). However, of the two tasks used for evaluating VBLaST, only the peg-transfer task showed a significant difference between the expert and novice groups (P = 0.003). Spearman correlation coefficient analysis between the two scores showed significant correlation for the peg-transfer task (Spearman coefficient 0.364; P = 0.023). Conclusions VBLaST demonstrated significant face and construct validity. A further set of studies, involving improvement to the current VBLaST system, is needed to thoroughly demonstrate face and construct validity for all the tasks. PMID:20201683

  3. Validity and reliability of a scale to measure genital body image.

    PubMed

    Zielinski, Ruth E; Kane-Low, Lisa; Miller, Janis M; Sampselle, Carolyn

    2012-01-01

    Women's body image dissatisfaction extends to body parts usually hidden from view--their genitals. Ability to measure genital body image is limited by lack of valid and reliable questionnaires. We subjected a previously developed questionnaire, the Genital Self Image Scale (GSIS) to psychometric testing using a variety of methods. Five experts determined the content validity of the scale. Then using four participant groups, factor analysis was performed to determine construct validity and to identify factors. Further construct validity was established using the contrasting groups approach. Internal consistency and test-retest reliability was determined. Twenty one of 29 items were considered content valid. Two items were added based on expert suggestions. Factor analysis was undertaken resulting in four factors, identified as Genital Confidence, Appeal, Function, and Comfort. The revised scale (GSIS-20) included 20 items explaining 59.4% of the variance. Women indicating an interest in genital cosmetic surgery exhibited significantly lower scores on the GSIS-20 than those who did not. The final 20 item scale exhibited internal reliability across all sample groups as well as test-retest reliability. The GSIS-20 provides a measure of genital body image demonstrating reliability and validity across several populations of women.

  4. A Investigation of the Conceptual Changes Resulting from the Use of Demonstrations in College Physics.

    NASA Astrophysics Data System (ADS)

    Gattis, Kenneth William

    1995-01-01

    The purpose was to investigate the acquisition and retrieval of physics concepts introduced to college physics students by classroom demonstrations. Three experimental groups of calculus-based physics classes were presented lessons on three different topics during the semester. The lessons, which were planned to deliver identical concepts and examples, were preceded by a short quiz and were followed by an identical posttest. One treatment group received "enhanced" demonstration lessons, which included a brief period of peer discussion prior to the demonstration lesson. The second treatment group received typical demonstration lessons, and the control group received traditional lectures. Both demonstration groups were found to have higher conceptual gains than the control group on the topic of force and motion, which featured an air track demonstration. No differences were found on the topic of conservation of energy. On the topic of angular momentum, the demonstration groups tended to have higher prediction gains and the control group had higher explanation gains. No differences were found between the gains of the two demonstration groups. Student interview responses recorded one to two weeks after the experimental lessons indicated that the lesson containing a "stool and dumbbell" demonstration in the treatment groups was more memorable than the corresponding angular momentum lesson seen by the control group. Demonstration group students who made conceptual gains on the quizzes were found to give more complete responses to problems; yet they used language that was similar to that used by demonstration group students making no gains. In recalling experimental lessons, the demonstration group students gave responses that were more complete and used more everyday language than the control group students. It was concluded that demonstrations may assist students on certain topics by (1) helping to make concepts more believable; (2) helping to explain concepts that have

  5. Development and Analytical Validation of an Immunoassay for Quantifying Serum Anti-Pertussis Toxin Antibodies Resulting from Bordetella pertussis Infection ▿

    PubMed Central

    Menzies, Sandra L.; Kadwad, Vijay; Pawloski, Lucia C.; Lin, Tsai-Lien; Baughman, Andrew L.; Martin, Monte; Tondella, Maria Lucia C.; Meade, Bruce D.

    2009-01-01

    Adequately sensitive and specific methods to diagnose pertussis in adolescents and adults are not widely available. Currently, no Food and Drug Administration-approved diagnostic assays are available for the serodiagnosis of Bordetella pertussis. Since concentrations of B. pertussis-specific antibodies tend to be high during the later phases of disease, a simple, rapid, easily transferable serodiagnostic test was developed. This article describes test development, initial evaluation of a prototype kit enzyme-linked immunosorbent assay (ELISA) in an interlaboratory collaborative study, and analytical validation. The data presented here demonstrate that the kit met all prespecified criteria for precision, linearity, and accuracy for samples with anti-pertussis toxin (PT) immunoglobulin G (IgG) antibody concentrations in the range of 50 to 150 ELISA units (EU)/ml, the range believed to be most relevant for serodiagnosis. The assay met the precision and linearity criteria for a wider range, namely, from 50 to 200 EU/ml; however, the accuracy criterion was not met at 200 EU/ml. When the newly adopted World Health Organization International Standard for pertussis antiserum (human) reference reagent was used to evaluate accuracy, the accuracy criteria were met from 50 to 200 international units/ml. In conclusion, the IgG anti-PT ELISA met all assay validation parameters within the range considered most relevant for serodiagnosis. This ELISA was developed and analytically validated as a user-friendly kit that can be used in both qualitative and quantitative formats. The technology for producing the kit is transferable to public health laboratories. PMID:19864485

  6. A Case Study for Probabilistic Methods Validation (MSFC Center Director's Discretionary Fund, Project No. 94-26)

    NASA Technical Reports Server (NTRS)

    Price J. M.; Ortega, R.

    1998-01-01

    Probabilistic method is not a universally accepted approach for the design and analysis of aerospace structures. The validity of this approach must be demonstrated to encourage its acceptance as it viable design and analysis tool to estimate structural reliability. The objective of this Study is to develop a well characterized finite population of similar aerospace structures that can be used to (1) validate probabilistic codes, (2) demonstrate the basic principles behind probabilistic methods, (3) formulate general guidelines for characterization of material drivers (such as elastic modulus) when limited data is available, and (4) investigate how the drivers affect the results of sensitivity analysis at the component/failure mode level.

  7. Individualism: a valid and important dimension of cultural differences between nations.

    PubMed

    Schimmack, Ulrich; Oishi, Shigehiro; Diener, Ed

    2005-01-01

    Oyserman, Coon, and Kemmelmeier's (2002) meta-analysis suggested problems in the measurement of individualism and collectivism. Studies using Hofstede's individualism scores show little convergent validity with more recent measures of individualism and collectivism. We propose that the lack of convergent validity is due to national differences in response styles. Whereas Hofstede statistically controlled for response styles, Oyserman et al.'s meta-analysis relied on uncorrected ratings. Data from an international student survey demonstrated convergent validity between Hofstede's individualism dimension and horizontal individualism when response styles were statistically controlled, whereas uncorrected scores correlated highly with the individualism scores in Oyserman et al.'s meta-analysis. Uncorrected horizontal individualism scores and meta-analytic individualism scores did not correlate significantly with nations' development, whereas corrected horizontal individualism scores and Hofstede's individualism dimension were significantly correlated with development. This pattern of results suggests that individualism is a valid construct for cross-cultural comparisons, but that the measurement of this construct needs improvement.

  8. Examining the Predictive Validity of NIH Peer Review Scores

    PubMed Central

    Lindner, Mark D.; Nakamura, Richard K.

    2015-01-01

    The predictive validity of peer review at the National Institutes of Health (NIH) has not yet been demonstrated empirically. It might be assumed that the most efficient and expedient test of the predictive validity of NIH peer review would be an examination of the correlation between percentile scores from peer review and bibliometric indices of the publications produced from funded projects. The present study used a large dataset to examine the rationale for such a study, to determine if it would satisfy the requirements for a test of predictive validity. The results show significant restriction of range in the applications selected for funding. Furthermore, those few applications that are funded with slightly worse peer review scores are not selected at random or representative of other applications in the same range. The funding institutes also negotiate with applicants to address issues identified during peer review. Therefore, the peer review scores assigned to the submitted applications, especially for those few funded applications with slightly worse peer review scores, do not reflect the changed and improved projects that are eventually funded. In addition, citation metrics by themselves are not valid or appropriate measures of scientific impact. The use of bibliometric indices on their own to measure scientific impact would likely increase the inefficiencies and problems with replicability already largely attributed to the current over-emphasis on bibliometric indices. Therefore, retrospective analyses of the correlation between percentile scores from peer review and bibliometric indices of the publications resulting from funded grant applications are not valid tests of the predictive validity of peer review at the NIH. PMID:26039440

  9. Airport Surface Movement Technologies: Atlanta Demonstrations Overview

    NASA Technical Reports Server (NTRS)

    Jones, Denise R.; Young, Steven D.

    1997-01-01

    A flight demonstration was conducted in August 1997 at the Hartsfield Atlanta (ATL) International Airport as part of low visibility landing and surface operations (LVLASO) research activities. This research was aimed at investigating technology to improve the safety and efficiency of aircraft movements on the surface during the operational phases of roll-out, turnoff, and taxi in any weather condition down to a runway visual range of 300 feet. The system tested at ATL was composed of airborne and ground-based components that were integrated to provide both the flight crew and controllers with supplemental information to enable safe, expedient surface operations. Experimental displays were installed on a Boeing 757-200 research aircraft in both headup and head-down formats. On the ground, an integrated system maintained surveillance of the airport surface and a controller interface provided routing and control instructions. While at ATL, the research aircraft performed a series of flight and taxi operations to show the validity of the operational concept at a major airport facility, to validate simulation findings, and to assess each of the individual technologies performance in an airport environment. The concept was demonstrated to over 100 visitors from the Federal Aviation Administration (FAA) and the aviation community. This paper gives an overview of the LVLASO system and ATL test activities.

  10. Experimental validation of FINDSITEcomb virtual ligand screening results for eight proteins yields novel nanomolar and micromolar binders

    PubMed Central

    2014-01-01

    Background Identification of ligand-protein binding interactions is a critical step in drug discovery. Experimental screening of large chemical libraries, in spite of their specific role and importance in drug discovery, suffer from the disadvantages of being random, time-consuming and expensive. To accelerate the process, traditional structure- or ligand-based VLS approaches are combined with experimental high-throughput screening, HTS. Often a single protein or, at most, a protein family is considered. Large scale VLS benchmarking across diverse protein families is rarely done, and the reported success rate is very low. Here, we demonstrate the experimental HTS validation of a novel VLS approach, FINDSITEcomb, across a diverse set of medically-relevant proteins. Results For eight different proteins belonging to different fold-classes and from diverse organisms, the top 1% of FINDSITEcomb’s VLS predictions were tested, and depending on the protein target, 4%-47% of the predicted ligands were shown to bind with μM or better affinities. In total, 47 small molecule binders were identified. Low nanomolar (nM) binders for dihydrofolate reductase and protein tyrosine phosphatases (PTPs) and micromolar binders for the other proteins were identified. Six novel molecules had cytotoxic activity (<10 μg/ml) against the HCT-116 colon carcinoma cell line and one novel molecule had potent antibacterial activity. Conclusions We show that FINDSITEcomb is a promising new VLS approach that can assist drug discovery. PMID:24936211

  11. Overview of RICOR's reliability theoretical analysis, accelerated life demonstration test results and verification by field data

    NASA Astrophysics Data System (ADS)

    Vainshtein, Igor; Baruch, Shlomi; Regev, Itai; Segal, Victor; Filis, Avishai; Riabzev, Sergey

    2018-05-01

    The growing demand for EO applications that work around the clock 24hr/7days a week, such as in border surveillance systems, emphasizes the need for a highly reliable cryocooler having increased operational availability and optimized system's Integrated Logistic Support (ILS). In order to meet this need, RICOR developed linear and rotary cryocoolers which achieved successfully this goal. Cryocoolers MTTF was analyzed by theoretical reliability evaluation methods, demonstrated by normal and accelerated life tests at Cryocooler level and finally verified by field data analysis derived from Cryocoolers operating at system level. The following paper reviews theoretical reliability analysis methods together with analyzing reliability test results derived from standard and accelerated life demonstration tests performed at Ricor's advanced reliability laboratory. As a summary for the work process, reliability verification data will be presented as a feedback from fielded systems.

  12. A Spanish Validation of the Canadian Adolescent Gambling Inventory (CAGI).

    PubMed

    Jiménez-Murcia, Susana; Granero, Roser; Stinchfield, Randy; Tremblay, Joël; Del Pino-Gutiérrez, Amparo; Moragas, Laura; Savvidou, Lamprini G; Fernández-Aranda, Fernando; Aymamí, Neus; Gómez-Peña, Mónica; Tárrega, Salomé; Gunnard, Katarina; Martín-Romera, Virginia; Steward, Trevor; Mestre-Bach, Gemma; Menchón, José M

    2017-01-01

    Aims: Large-scale epidemiological studies show a significant prevalence of gambling disorder (GD) during adolescence and emerging adulthood, and highlight the need to identify gambling-related behaviors at early ages. However, there are only a handful of screening instruments for this population and many studies measuring youth gambling problems use adult instruments that may not be developmentally appropriate. The aim of this study was to validate a Spanish version of the Canadian Adolescent Gambling Inventory (CAGI) among late adolescent and young adults and to explore its psychometric properties. Methods: The sample (16-29 years old) included a clinical group ( n = 55) with GD patients and a control group ( n = 340). Results: Exploratory factor analysis yielded one factor as the best model. This 24-item scale demonstrated satisfactory reliability (internal consistency, Cronbach's alpha, α = 0.91), satisfactory convergent validity as measured by correlation with South Oaks Gambling Screen ( r = 0.74), and excellent classification accuracy (AUC = 0.99; sensitivity = 0.98; and specificity = 0.99). Conclusion: Our results provide empirical support for our validation of the Spanish version of the CAGI. We uphold that the Spanish CAGI can be used as a brief, reliable, and valid instrument to assess gambling problems in Spanish youth.

  13. A Spanish Validation of the Canadian Adolescent Gambling Inventory (CAGI)

    PubMed Central

    Jiménez-Murcia, Susana; Granero, Roser; Stinchfield, Randy; Tremblay, Joël; del Pino-Gutiérrez, Amparo; Moragas, Laura; Savvidou, Lamprini G.; Fernández-Aranda, Fernando; Aymamí, Neus; Gómez-Peña, Mónica; Tárrega, Salomé; Gunnard, Katarina; Martín-Romera, Virginia; Steward, Trevor; Mestre-Bach, Gemma; Menchón, José M.

    2017-01-01

    Aims: Large-scale epidemiological studies show a significant prevalence of gambling disorder (GD) during adolescence and emerging adulthood, and highlight the need to identify gambling-related behaviors at early ages. However, there are only a handful of screening instruments for this population and many studies measuring youth gambling problems use adult instruments that may not be developmentally appropriate. The aim of this study was to validate a Spanish version of the Canadian Adolescent Gambling Inventory (CAGI) among late adolescent and young adults and to explore its psychometric properties. Methods: The sample (16–29 years old) included a clinical group (n = 55) with GD patients and a control group (n = 340). Results: Exploratory factor analysis yielded one factor as the best model. This 24-item scale demonstrated satisfactory reliability (internal consistency, Cronbach’s alpha, α = 0.91), satisfactory convergent validity as measured by correlation with South Oaks Gambling Screen (r = 0.74), and excellent classification accuracy (AUC = 0.99; sensitivity = 0.98; and specificity = 0.99). Conclusion: Our results provide empirical support for our validation of the Spanish version of the CAGI. We uphold that the Spanish CAGI can be used as a brief, reliable, and valid instrument to assess gambling problems in Spanish youth. PMID:28223961

  14. [MusiQol: international questionnaire investigating quality of life in multiple sclerosis: validation results for the German subpopulation in an international comparison].

    PubMed

    Flachenecker, P; Vogel, U; Simeoni, M C; Auquier, P; Rieckmann, P

    2011-10-01

    The existing health-related quality of life questionnaires on multiple sclerosis (MS) only partially reflect the patient's point of view on the reduction of activities of daily living. Their development and validation was not performed in different languages. That is what prompted the development of the Multiple Sclerosis International Quality of Life (MusiQoL) Questionnaire as an international multidimensional measurement instrument. This paper presents this new development and the results of the German subgroup versus the total international sample. A total of 1,992 MS patients from 15 countries, including 209 German patients, took part in the study between January 2004 and February 2005. The patients took the MusiQoL survey at baseline and at 21±7 days as well as completing a symptom-related checklist and the SF-36 short form survey. Demographics, history and MS classification data were also generated. Reproducibility, sensitivity, convergent and discriminant validity were analysed. Convergent and discriminant validity and reproducibility were satisfactory for all dimensions of the MusiQoL. The dimensional scores correlated moderately but significantly with the SF-36 scores, but showed a discriminant validity in terms of gender, socioeconomic status and health status that was more pronounced in the overall population than in the German subpopulation. The highest correlations were observed between the MusiQoL dimension of activities of daily living and the Expanded Disability Status Scale (EDSS). The results of this study confirm the validity and reliability of MusiQoL as an instrument for measuring the quality of life of German and international MS patients.

  15. Validation of a clinical critical thinking skills test in nursing

    PubMed Central

    2015-01-01

    Purpose: The purpose of this study was to develop a revised version of the clinical critical thinking skills test (CCTS) and to subsequently validate its performance. Methods: This study is a secondary analysis of the CCTS. Data were obtained from a convenience sample of 284 college students in June 2011. Thirty items were analyzed using item response theory and test reliability was assessed. Test-retest reliability was measured using the results of 20 nursing college and graduate school students in July 2013. The content validity of the revised items was analyzed by calculating the degree of agreement between instrument developer intention in item development and the judgments of six experts. To analyze response process validity, qualitative data related to the response processes of nine nursing college students obtained through cognitive interviews were analyzed. Results: Out of initial 30 items, 11 items were excluded after the analysis of difficulty and discrimination parameter. When the 19 items of the revised version of the CCTS were analyzed, levels of item difficulty were found to be relatively low and levels of discrimination were found to be appropriate or high. The degree of agreement between item developer intention and expert judgments equaled or exceeded 50%. Conclusion: From above results, evidence of the response process validity was demonstrated, indicating that subjects respondeds as intended by the test developer. The revised 19-item CCTS was found to have sufficient reliability and validity and will therefore represents a more convenient measurement of critical thinking ability. PMID:25622716

  16. VALFAST: Secure Probabilistic Validation of Hundreds of Kepler Planet Candidates

    NASA Astrophysics Data System (ADS)

    Morton, Tim; Petigura, E.; Johnson, J. A.; Howard, A.; Marcy, G. W.; Baranec, C.; Law, N. M.; Riddle, R. L.; Ciardi, D. R.; Robo-AO Team

    2014-01-01

    The scope, scale, and tremendous success of the Kepler mission has necessitated the rapid development of probabilistic validation as a new conceptual framework for analyzing transiting planet candidate signals. While several planet validation methods have been independently developed and presented in the literature, none has yet come close to addressing the entire Kepler survey. I present the results of applying VALFAST---a planet validation code based on the methodology described in Morton (2012)---to every Kepler Object of Interest. VALFAST is unique in its combination of detail, completeness, and speed. Using the transit light curve shape, realistic population simulations, and (optionally) diverse follow-up observations, it calculates the probability that a transit candidate signal is the result of a true transiting planet or any of a number of astrophysical false positive scenarios, all in just a few minutes on a laptop computer. In addition to efficiently validating the planetary nature of hundreds of new KOIs, this broad application of VALFAST also demonstrates its ability to reliably identify likely false positives. This extensive validation effort is also the first to incorporate data from all of the largest Kepler follow-up observing efforts: the CKS survey of ~1000 KOIs with Keck/HIRES, the Robo-AO survey of >1700 KOIs, and high-resolution images obtained through the Kepler Follow-up Observing Program. In addition to enabling the core science that the Kepler mission was designed for, this methodology will be critical to obtain statistical results from future surveys such as TESS and PLATO.

  17. Evaluation of a methodology to validate National Death Index retrieval results among a cohort of U.S. service members.

    PubMed

    Skopp, Nancy A; Smolenski, Derek J; Schwesinger, Daniel A; Johnson, Christopher J; Metzger-Abamukong, Melinda J; Reger, Mark A

    2017-06-01

    Accurate knowledge of the vital status of individuals is critical to the validity of mortality research. National Death Index (NDI) and NDI-Plus are comprehensive epidemiological resources for mortality ascertainment and cause of death data that require additional user validation. Currently, there is a gap in methods to guide validation of NDI search results rendered for active duty service members. The purpose of this research was to adapt and evaluate the CDC National Program of Cancer Registries (NPCR) algorithm for mortality ascertainment in a large military cohort. We adapted and applied the NPCR algorithm to a cohort of 7088 service members on active duty at the time of death at some point between 2001 and 2009. We evaluated NDI validity and NDI-Plus diagnostic agreement against the Department of Defense's Armed Forces Medical Examiner System (AFMES). The overall sensitivity of the NDI to AFMES records after the application of the NPCR algorithm was 97.1%. Diagnostic estimates of measurement agreement between the NDI-Plus and the AFMES cause of death groups were high. The NDI and NDI-Plus can be successfully used with the NPCR algorithm to identify mortality and cause of death among active duty military cohort members who die in the United States. Published by Elsevier Inc.

  18. Cultural adaptation and validation of an instrument on barriers for the use of research results.

    PubMed

    Ferreira, Maria Beatriz Guimarães; Haas, Vanderlei José; Dantas, Rosana Aparecida Spadoti; Felix, Márcia Marques Dos Santos; Galvão, Cristina Maria

    2017-03-02

    to culturally adapt The Barriers to Research Utilization Scale and to analyze the metric validity and reliability properties of its Brazilian Portuguese version. methodological research conducted by means of the cultural adaptation process (translation and back-translation), face and content validity, construct validity (dimensionality and known groups) and reliability analysis (internal consistency and test-retest). The sample consisted of 335 nurses, of whom 43 participated in the retest phase. the validity of the adapted version of the instrument was confirmed. The scale investigates the barriers for the use of the research results in clinical practice. Confirmatory factorial analysis demonstrated that the Brazilian Portuguese version of the instrument is adequately adjusted to the dimensional structure the scale authors originally proposed. Statistically significant differences were observed among the nurses holding a Master's or Doctoral degree, with characteristics favorable to Evidence-Based Practice, and working at an institution with an organizational cultural that targets this approach. The reliability showed a strong correlation (r ranging between 0.77 and 0.84, p<0.001) and the internal consistency was adequate (Cronbach's alpha ranging between 0.77 and 0.82). the Brazilian Portuguese version of The Barriers Scale was valid and reliable in the group studied. efectuar la adaptación cultural del instrumento The Barriers to Research Utilization Scale, y analizar propiedades métricas de validez y confiabilidad de su versión para portugués brasileño. investigación metodológica conducida mediante el proceso de adaptación cultural (traducción y retrotraducción), validez de faz y contenido, validez de constructo (dimensionalidad y grupos conocidos) y análisis de fiabilidad (consistencia interna y test-retest). La muestra incluyó 335 enfermeros, de los cuales 43 participaron de la etapa retest. la validez de la versión adaptada del instrumento fue

  19. Five-Factor Screener in the 2005 National Health Interview Survey Cancer Control Supplement: Validation Results

    Cancer.gov

    Risk Factor Assessment Branch staff have assessed indirectly the validity of parts of the Five-Factor Screener in two studies: NCI's Observing Protein and Energy (OPEN) Study and the Eating at America's Table Study (EATS). In both studies, multiple 24-hour recalls in conjunction with a measurement error model were used to assess validity.

  20. Accuracy assessment/validation methodology and results of 2010–11 land-cover/land-use data for Pools 13, 26, La Grange, and Open River South, Upper Mississippi River System

    USGS Publications Warehouse

    Jakusz, J.W.; Dieck, J.J.; Langrehr, H.A.; Ruhser, J.J.; Lubinski, S.J.

    2016-01-11

    Similar to an AA, validation involves generating random points based on the total area for each map class. However, instead of collecting field data, two or three individuals not involved with the photo-interpretative mapping separately review each of the points onscreen and record a best-fit vegetation type(s) for each site. Once the individual analyses are complete, results are joined together and a comparative analysis is performed. The objective of this initial analysis is to identify areas where the validation results were in agreement (matches) and areas where validation results were in disagreement (mismatches). The two or three individuals then perform an analysis, looking at each mismatched site, and agree upon a final validation class. (If two vegetation types at a specific site appear to be equally prevalent, the validation team is permitted to assign the site two best-fit vegetation types.) Following the validation team’s comparative analysis of vegetation assignments, the data are entered into a database and compared to the mappers’ vegetation assignments. Agreements and disagreements between the map and validation classes are identified, and a contingency table is produced. This document presents the AA processes/results for Pools 13 and La Grange, as well as the validation process/results for Pools 13 and 26 and Open River South.

  1. Expert system verification and validation survey. Delivery 2: Survey results

    NASA Technical Reports Server (NTRS)

    1990-01-01

    The purpose is to determine the state-of-the-practice in Verification and Validation (V and V) of Expert Systems (ESs) on current NASA and industry applications. This is the first task of the series which has the ultimate purpose of ensuring that adequate ES V and V tools and techniques are available for Space Station Knowledge Based Systems development. The strategy for determining the state-of-the-practice is to check how well each of the known ES V and V issues are being addressed and to what extent they have impacted the development of ESs.

  2. Non-physics peer demonstrators in undergraduate laboratories: a study of students’ perceptions

    NASA Astrophysics Data System (ADS)

    Braun, Michael; Kirkup, Les

    2016-01-01

    Laboratory demonstrators play a crucial role in facilitating students’ learning in physics subjects. Inspired by the success of peer-led activities, we introduced peer demonstrators to support student learning in first-year physics subjects that enrol students not intending to major in physics. Surveys were administered to 1700 students over 4 years in four subjects to examine student perceptions of how demonstrators assisted them in the laboratory. Scores awarded to peer demonstrators by students were no lower than those awarded to demonstrators traditionally employed in the first year physics laboratory. These latter demonstrators were drawn mainly from the ranks of physics research students. The findings validate the recruitment of peer demonstrators and will be used to inform the recruitment and support programmes for laboratory demonstrators.

  3. Reliability and Validity of the Lichtenberg Financial Decision Screening Scale.

    PubMed

    Lichtenberg, Peter A; Teresi, Jeanne A; Ocepek-Welikson, Katja; Eimicke, Joseph P

    2017-03-01

    The scarcity of empirically validated assessment instruments continues to impede the work of professionals in a number of fields, including medicine, finance, and estate planning; adult protective services; and criminal justice-and, more importantly, it impedes their ability to effectively assist and, in some case, protect their clients. Other professionals (e.g. legal, financial, medical, mental health services) are in a position to prevent financial exploitation and would benefit from access to new instruments. The Lichtenberg Financial Decision Screening Scale (LFDSS) was introduced in 2016, along with evidence for its convergent validity (Lichtenberg et al., 2016). Using a sample of 213 participants, this study investigated the internal consistency of the LFDSS and its criterion validity based on ratings by professionals using the scale. Results demonstrate that the LFDSS has excellent internal consistency and clinical utility properties. This paper provides support for use of the LFDSS as a reliable and valid instrument. The LFDSS and instructions for its use are included in the article, along with information about online tools and support.

  4. Examining construct and predictive validity of the Health-IT Usability Evaluation Scale: confirmatory factor analysis and structural equation modeling results.

    PubMed

    Yen, Po-Yin; Sousa, Karen H; Bakken, Suzanne

    2014-10-01

    In a previous study, we developed the Health Information Technology Usability Evaluation Scale (Health-ITUES), which is designed to support customization at the item level. Such customization matches the specific tasks/expectations of a health IT system while retaining comparability at the construct level, and provides evidence of its factorial validity and internal consistency reliability through exploratory factor analysis. In this study, we advanced the development of Health-ITUES to examine its construct validity and predictive validity. The health IT system studied was a web-based communication system that supported nurse staffing and scheduling. Using Health-ITUES, we conducted a cross-sectional study to evaluate users' perception toward the web-based communication system after system implementation. We examined Health-ITUES's construct validity through first and second order confirmatory factor analysis (CFA), and its predictive validity via structural equation modeling (SEM). The sample comprised 541 staff nurses in two healthcare organizations. The CFA (n=165) showed that a general usability factor accounted for 78.1%, 93.4%, 51.0%, and 39.9% of the explained variance in 'Quality of Work Life', 'Perceived Usefulness', 'Perceived Ease of Use', and 'User Control', respectively. The SEM (n=541) supported the predictive validity of Health-ITUES, explaining 64% of the variance in intention for system use. The results of CFA and SEM provide additional evidence for the construct and predictive validity of Health-ITUES. The customizability of Health-ITUES has the potential to support comparisons at the construct level, while allowing variation at the item level. We also illustrate application of Health-ITUES across stages of system development. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://group.bmj.com/group/rights-licensing/permissions.

  5. Results of the Clarus Regional Demonstrations : Evaluation of Enhanced Road Weather Forecasting

    DOT National Transportation Integrated Search

    2012-01-01

    The Clarus Initiative is a research effort of the U.S. Department of Transportation Intelligent Transportation Systems Joint Program Office and the Federal Highway Administrations Road Weather Management Program to develop and demonstrate an integ...

  6. Reliability and Validity of the Korean Version of the Cancer Stigma Scale.

    PubMed

    So, Hyang Sook; Chae, Myeong Jeong; Kim, Hye Young

    2017-02-01

    In this study the reliability and validity of the Korean version of the Cancer Stigma Scale (KCSS) was evaluated. The KCSS was formed through translation and modification of Cataldo Lung Cancer Stigma Scale. The KCSS, Psychological Symptom Inventory (PSI), and European Organization for Research and Treatment of Cancer Quality of Life Questionnaire - Core 30 (EORTC QLQ-C30) were administered to 247 men and women diagnosed with one of the five major cancers. Construct validity, item convergent and discriminant validity, concurrent validity, known-group validity, and internal consistency reliability of the KCSS were evaluated. Exploratory factor analysis supported the construct validity with a six-factor solution; that explained 65.7% of the total variance. The six-factor model was validated by confirmatory factor analysis (Q (χ²/df)= 2.28, GFI=.84, AGFI=.81, NFI=.80, TLI=.86, RMR=.03, and RMSEA=.07). Concurrent validity was demonstrated with the QLQ-C30 (global: r=-.44; functional: r=-.19; symptom: r=.42). The KCSS had known-group validity. Cronbach's alpha coefficient for the 24 items was .89. The results of this study suggest that the 24-item KCSS has relatively acceptable reliability and validity and can be used in clinical research to assess cancer stigma and its impacts on health-related quality of life in Korean cancer patients. © 2017 Korean Society of Nursing Science

  7. Validation of Bayesian analysis of compartmental kinetic models in medical imaging.

    PubMed

    Sitek, Arkadiusz; Li, Quanzheng; El Fakhri, Georges; Alpert, Nathaniel M

    2016-10-01

    Kinetic compartmental analysis is frequently used to compute physiologically relevant quantitative values from time series of images. In this paper, a new approach based on Bayesian analysis to obtain information about these parameters is presented and validated. The closed-form of the posterior distribution of kinetic parameters is derived with a hierarchical prior to model the standard deviation of normally distributed noise. Markov chain Monte Carlo methods are used for numerical estimation of the posterior distribution. Computer simulations of the kinetics of F18-fluorodeoxyglucose (FDG) are used to demonstrate drawing statistical inferences about kinetic parameters and to validate the theory and implementation. Additionally, point estimates of kinetic parameters and covariance of those estimates are determined using the classical non-linear least squares approach. Posteriors obtained using methods proposed in this work are accurate as no significant deviation from the expected shape of the posterior was found (one-sided P>0.08). It is demonstrated that the results obtained by the standard non-linear least-square methods fail to provide accurate estimation of uncertainty for the same data set (P<0.0001). The results of this work validate new methods for a computer simulations of FDG kinetics. Results show that in situations where the classical approach fails in accurate estimation of uncertainty, Bayesian estimation provides an accurate information about the uncertainties in the parameters. Although a particular example of FDG kinetics was used in the paper, the methods can be extended for different pharmaceuticals and imaging modalities. Copyright © 2016 Associazione Italiana di Fisica Medica. Published by Elsevier Ltd. All rights reserved.

  8. Evaluation of the Validity and Reliability of the Waterlow Pressure Ulcer Risk Assessment Scale

    PubMed Central

    Charalambous, Charalambos; Koulori, Agoritsa; Vasilopoulos, Aristidis; Roupa, Zoe

    2018-01-01

    Introduction Prevention is the ideal strategy to tackle the problem of pressure ulcers. Pressure ulcer risk assessment scales are one of the most pivotal measures applied to tackle the problem, much criticisms has been developed regarding the validity and reliability of these scales. Objective To investigate the validity and reliability of the Waterlow pressure ulcer risk assessment scale. Method The methodology used is a narrative literature review, the bibliography was reviewed through Cinahl, Pubmed, EBSCO, Medline and Google scholar, 26 scientific articles where identified. The articles where chosen due to their direct correlation with the objective under study and their scientific relevance. Results The construct and face validity of the Waterlow appears adequate, but with regards to content validity changes in the category age and gender can be beneficial. The concurrent validity cannot be assessed. The predictive validity of the Waterlow is characterized by high specificity and low sensitivity. The inter-rater reliability has been demonstrated to be inadequate, this may be due to lack of clear definitions within the categories and differentiating level of knowledge between the users. Conclusion Due to the limitations presented regarding the validity and reliability of the Waterlow pressure ulcer risk assessment scale, the scale should be used in conjunction with clinical assessment to provide optimum results. PMID:29736104

  9. Face, content, and construct validity of human placenta as a haptic training tool in neurointerventional surgery.

    PubMed

    Ribeiro de Oliveira, Marcelo Magaldi; Nicolato, Arthur; Santos, Marcilea; Godinho, Joao Victor; Brito, Rafael; Alvarenga, Alexandre; Martins, Ana Luiza Valle; Prosdocimi, André; Trivelato, Felipe Padovani; Sabbagh, Abdulrahman J; Reis, Augusto Barbosa; Maestro, Rolando Del

    2016-05-01

    OBJECT The development of neurointerventional treatments of central nervous system disorders has resulted in the need for adequate training environments for novice interventionalists. Virtual simulators offer anatomical definition but lack adequate tactile feedback. Animal models, which provide more lifelike training, require an appropriate infrastructure base. The authors describe a training model for neurointerventional procedures using the human placenta (HP), which affords haptic training with significantly fewer resource requirements, and discuss its validation. METHODS Twelve HPs were prepared for simulated endovascular procedures. Training exercises performed by interventional neuroradiologists and novice fellows were placental angiography, stent placement, aneurysm coiling, and intravascular liquid embolic agent injection. RESULTS The endovascular training exercises proposed can be easily reproduced in the HP. Face, content, and construct validity were assessed by 6 neurointerventional radiologists and 6 novice fellows in interventional radiology. CONCLUSIONS The use of HP provides an inexpensive training model for the training of neurointerventionalists. Preliminary validation results show that this simulation model has face and content validity and has demonstrated construct validity for the interventions assessed in this study.

  10. Edible Astronomy Demonstrations

    NASA Astrophysics Data System (ADS)

    Lubowich, D. A.

    2006-08-01

    By using astronomy demonstrations with edible ingredients, I have been able to increase student interest and knowledge of astronomical concepts. This approach has been successful with all age groups from elementary school through college students. I will present some of the edible demonstrations I have created including using popcorn to simulate radioactivity; using chocolate, nuts, and marshmallows to illustrate density and differentiation during the formation of the planets; and making big-bang brownies or chocolate chip-cookies to illustrate the expansion of the Universe. Sometimes the students eat the results of the astronomical demonstrations. These demonstrations are an effective teaching tool and the students remember these demonstrations after they are presented.

  11. RESULTS OF THE SEPTEMBER 1997 DOE/EPA DEMONSTRATION OF MULTIMETAL CONTINUOUS EMISSION MONITORING TECHNOLOGIES

    EPA Science Inventory

    In September 1997, the U.S. Department of Energy (DOE) and U.S. Environmental Protection Agency (EPA) co-sponsored a demonstration of several multimetal continuous emission monitos (CEMs). The demonstration, performed at the EPA National Risk Management Research Laboratory, Air P...

  12. The development and initial validation of the Decent Work Scale.

    PubMed

    Duffy, Ryan D; Allan, Blake A; England, Jessica W; Blustein, David L; Autin, Kelsey L; Douglass, Richard P; Ferreira, Joaquim; Santos, Eduardo J R

    2017-03-01

    Decent work is positioned as the centerpiece of the recently developed Psychology of Working Theory (PWT; Duffy, Blustein, Diemer, & Autin, 2016). However, to date, no instrument exists which assesses all 5 components of decent work from a psychological perspective. In the current study, we developed the Decent Work Scale (DWS) and demonstrated several aspects of validity with 2 samples of working adults. In Study 1 (N = 275), a large pool of items were developed and exploratory factor analysis was conducted resulting in a final 15-item scale with 5 factors/subscales corresponding to the 5 components of decent work: (a) physically and interpersonally safe working conditions, (b) access to health care, (c) adequate compensation, (d) hours that allow for free time and rest, and (e) organizational values that complement family and social values. In Study 2 (N = 589), confirmatory factor analysis demonstrated that a 5-factor, bifactor model offered the strongest and most parsimonious fit to the data. Configural, metric, and scalar invariance models were tested demonstrating that the structure of the instrument did not differ across gender, income, social class, and majority/minority racial/ethnic groups. Finally, the overall scale score and 5 subscale scores correlated in the expected directions with similar constructs supporting convergent and discriminant evidence of validity, and subscale scores evidenced predictive validity in the prediction of job satisfaction, work meaning, and withdrawal intentions. The development of this scale provides a useful tool for researchers and practitioners seeking to assess the attainment of decent work among employed adults. (PsycINFO Database Record (c) 2017 APA, all rights reserved).

  13. Development and validation of a stock addiction inventory (SAI).

    PubMed

    Youn, HyunChul; Choi, Jung-Seok; Kim, Dai-Jin; Choi, Sam-Wook

    2016-01-01

    Investing in financial markets is promoted and protected by the government as an essential economic activity, but can turn into a gambling addiction problem. Until now, few scales have widely been used to identify gambling addicts in financial markets. This study aimed to develop a self-rating scale to distinguish them. In addition, the reliability and validity of the stock addiction inventory (SAI) were demonstrated. A set of questionnaires, including the SAI, south oaks gambling screen (SOGS), and DSM-5 diagnostic criteria, for gambling disorder was completed by 1005 participants. Factor analysis, internal consistency testing, t tests, analysis of variance, and partial correlation analysis were conducted to verify the reliability and validity of SAI. The factor analysis results showed the final SAI consisting of two factors and nine items. The internal consistency and concurrent validity of SAI were verified. The Cronbach's α for the total scale was 0.892, and the SAI and its factors were significantly correlated with SOGS. This study developed a specific scale for financial market investments or trading; this scale proved to be reliable and valid. Our scale expands the understanding of gambling addiction in financial markets and provides a diagnostic reference.

  14. Measuring social alienation in adolescence: translation and validation of the Jessor and Jessor Social Alienation Scale.

    PubMed

    Safipour, Jalal; Tessma, Mesfin Kassaye; Higginbottom, Gina; Emami, Azita

    2010-12-01

    The objective of the study is to translate and examine the reliability and validity of the Jessor and Jessor Social Alienation Scale for use in a Swedish context. The study involved four phases of testing: (1) Translation and back-translation; (2) a pilot test to evaluate the translation; (3) reliability testing; and (4) a validity test. Main participants of this study were 446 students (Age = 15-19, SD = 1.01, Mean = 17). Results from the reliability test showed high internal consistency and stability. Face, content and construct validity were demonstrated using experts and confirmatory factor analysis. The results of testing the Swedish version of the alienation scale revealed an acceptable level of reliability and validity, and is appropriate for use in the Swedish context. © 2010 The Authors. Scandinavian Journal of Psychology © 2010 The Scandinavian Psychological Associations.

  15. Validation results of the IAG Dancer project for distributed GPS analysis

    NASA Astrophysics Data System (ADS)

    Boomkamp, H.

    2012-12-01

    The number of permanent GPS stations in the world has grown far too large to allow processing of all this data at analysis centers. The majority of these GPS sites do not even make their observation data available to the analysis centers, for various valid reasons. The current ITRF solution is still based on centralized analysis by the IGS, and subsequent densification of the reference frame via regional network solutions. Minor inconsistencies in analysis methods, software systems and data quality imply that this centralized approach is unlikely to ever reach the ambitious accuracy objectives of GGOS. The dependence on published data also makes it clear that a centralized approach will never provide a true global ITRF solution for all GNSS receivers in the world. If the data does not come to the analysis, the only alternative is to bring the analysis to the data. The IAG Dancer project has implemented a distributed GNSS analysis system on the internet in which each receiver can have its own analysis center in the form of a freely distributed JAVA peer-to-peer application. Global parameters for satellite orbits, clocks and polar motion are solved via a distributed least squares solution among all participating receivers. A Dancer instance can run on any computer that has simultaneous access to the receiver data and to the public internet. In the future, such a process may be embedded in the receiver firmware directly. GPS network operators can join the Dancer ITRF realization without having to publish their observation data or estimation products. GPS users can run a Dancer process without contributing to the global solution, to have direct access to the ITRF in near real-time. The Dancer software has been tested on-line since late 2011. A global network of processes has gradually evolved to allow stabilization and tuning of the software in order to reach a fully operational system. This presentation reports on the current performance of the Dancer system, and

  16. The National SAT Validity Study: Sharing Results from Recent College Success Research

    ERIC Educational Resources Information Center

    Shaw, Emily J.; McKenzie, Elizabeth

    2010-01-01

    [Slides] presented at the annual conference of the Southern Association for College Admission Counseling, April 2010. This presentation summarizes recent research from the national SAT Validity Study and includes information on the Admitted Class Evaluation Service (ACES) system and how ACES can help institutions conduct their own validity…

  17. Continued Validation of the O-SCORE (Ottawa Surgical Competency Operating Room Evaluation): Use in the Simulated Environment.

    PubMed

    MacEwan, Matthew J; Dudek, Nancy L; Wood, Timothy J; Gofton, Wade T

    2016-01-01

    -SCORE. There was strong agreement between two independent observers using the O-SCORE. Ratings on the O-SCORE also demonstrated equivalence to scores on the most validated technical evaluation tool (OSATS). These results suggest that the O-SCORE demonstrates accurate and reproducible results when used in a randomized and blinded fashion providing continued validity evidence for this tool in the evaluation of surgical competence in the trainees.

  18. Four experimental demonstrations of active vibration control for flexible structures

    NASA Technical Reports Server (NTRS)

    Phillips, Doug; Collins, Emmanuel G., Jr.

    1990-01-01

    Laboratory experiments designed to test prototype active-vibration-control systems under development for future flexible space structures are described, summarizing previously reported results. The control-synthesis technique employed for all four experiments was the maximum-entropy optimal-projection (MEOP) method (Bernstein and Hyland, 1988). Consideration is given to: (1) a pendulum experiment on large-amplitude LF dynamics; (2) a plate experiment on broadband vibration suppression in a two-dimensional structure; (3) a multiple-hexagon experiment combining the factors studied in (1) and (2) to simulate the complexity of a large space structure; and (4) the NASA Marshall ACES experiment on a lightweight deployable 45-foot beam. Extensive diagrams, drawings, graphs, and photographs are included. The results are shown to validate the MEOP design approach, demonstrating that good performance is achievable using relatively simple low-order decentralized controllers.

  19. Validation of the Implementation Leadership Scale (ILS) with Supervisors' Self-Ratings.

    PubMed

    Torres, Elisa M; Ehrhart, Mark G; Beidas, Rinad S; Farahnak, Lauren R; Finn, Natalie K; Aarons, Gregory A

    2018-01-01

    Although often discussed, there is a lack of empirical research on the role of leadership in the management and delivery of health services. The implementation leadership scale (ILS) assesses the degree to which leaders are knowledgeable, proactive, perseverant, and supportive during evidence-based practice (EBP) implementation. The purpose of this study was to examine the psychometric properties of the ILS for leaders' self-ratings using a sample of mental health clinic supervisors (N = 119). Supervisors (i.e., leaders) completed surveys including self-ratings of their implementation leadership. Confirmatory factor analysis, reliability, and validity of the ILS were evaluated. The ILS factor structure was supported in the sample of supervisors. Results demonstrated internal consistency reliability and validity. Cronbach alpha's ranged from 0.92 to 0.96 for the ILS subscales and 0.95 for the ILS overall scale. The factor structure replication and reliability of the ILS in a sample of supervisors demonstrates its applicability with employees across organizational levels.

  20. Validation study of the EORTC information questionnaire (EORTC QLQ-INFO25) in Iranian cancer patients.

    PubMed

    Asadi-Lari, Mohsen; Ahmadi Pishkuhi, Mahin; Almasi-Hashiani, Amir; Safiri, Saeid; Sepidarkish, Mahdi

    2015-07-01

    Developing a tool for measuring patient's needs is a vital step in the process of cancer treatment and research. In recent years, the European Organization for Research and Treatment of Cancer (EORTC) made a questionnaire to measure cancer patients' received information. Since validity and reliability of any instrument should be evaluated in the new environment and culture, the aim of this study was to assess the validity and reliability of the EORTC QLQ-INFO25 in Iranian cancer patients. One hundred seventy-three patients with different stages of cancer filled questionnaire EORTC QLQ-INFO25, EORTC QLQ-C30, and EORTC IN-PATSAT32. Twenty-five patients answered the questionnaire twice at an interval of 2 weeks. Reliability and validity of the questionnaire was measured by Cronbach's alpha, interclass correlation, test retest, inter-rater agreement (IRA), and exploratory factorial analyses. Using a conservative approach, the IRA for the overall relevancy and clarity of the tool was 87/86% and 83.33%, respectively. Overall appropriateness and clarity were 94.13 and 91.87%, respectively. Overall integrity of the instrument was determined to be 85%. Cronbach's alpha coefficients for all domains and total inventory were top 70 and 90%, respectively. Interclass correlation index ranges between 0.708 and 0.965. Exploratory factorial analyses demonstrate six fields suitable for instrument. Correlation between areas of the questionnaires EORTC QLQ-INFO25 and EORTC in-Patsat32 represents the convergent validity of the questionnaire. Also, results show a standard divergent validity in all domains of the questionnaire (Rho <0.3). Low correlation between the areas of the questionnaires EORTC QLQ-INFO25 and EORTC QLQ-C30 (<0.3) demonstrates the divergence validity of the questionnaire. The results showed that Persian version of the questionnaire EORTC QLQ-INFO25 is a reliable and valid instrument for measuring the perception of information in cancer patients.

  1. Towards Automatic Validation and Healing of Citygml Models for Geometric and Semantic Consistency

    NASA Astrophysics Data System (ADS)

    Alam, N.; Wagner, D.; Wewetzer, M.; von Falkenhausen, J.; Coors, V.; Pries, M.

    2013-09-01

    A steadily growing number of application fields for large 3D city models have emerged in recent years. Like in many other domains, data quality is recognized as a key factor for successful business. Quality management is mandatory in the production chain nowadays. Automated domain-specific tools are widely used for validation of business-critical data but still common standards defining correct geometric modeling are not precise enough to define a sound base for data validation of 3D city models. Although the workflow for 3D city models is well-established from data acquisition to processing, analysis and visualization, quality management is not yet a standard during this workflow. Processing data sets with unclear specification leads to erroneous results and application defects. We show that this problem persists even if data are standard compliant. Validation results of real-world city models are presented to demonstrate the potential of the approach. A tool to repair the errors detected during the validation process is under development; first results are presented and discussed. The goal is to heal defects of the models automatically and export a corrected CityGML model.

  2. Face validity, construct validity and training benefits of a virtual reality TURP simulator.

    PubMed

    Bright, Elizabeth; Vine, Samuel; Wilson, Mark R; Masters, Rich S W; McGrath, John S

    2012-01-01

    To assess face validity, construct validity and the training benefits of a virtual reality TURP simulator. 11 novices (no TURP experience) and 7 experts (>200 TURP's) completed a virtual reality median lobe prostate resection task on the TURPsim™ (Simbionix USA Corp., Cleveland, OH). Performance indicators (percentage of prostate resected (PR), percentage of capsular resection (CR) and time diathermy loop active without tissue contact (TAWC) were recorded via the TURPsim™ and compared between novices and experts to assess construct validity. Verbal comments provided by experts following task completion were used to assess face validity. Repeated attempts of the task by the novices were analysed to assess the training benefits of the TURPsim™. Experts resected a significantly greater percentage of prostate per minute (p < 0.01) and had significantly less active diathermy time without tissue contact (p < 0.01) than novices. After practice, novices were able to perform the simulation more effectively, with significant improvement in all measured parameters. Improvement in performance was noted in novices following repetitive training, as evidenced by improved TAWC scores that were not significantly different from the expert group (p = 0.18). This study has established face and construct validity for the TURPsim™. The potential benefit in using this tool to train novices has also been demonstrated. Copyright © 2012 Surgical Associates Ltd. Published by Elsevier Ltd. All rights reserved.

  3. Validation of a clinical critical thinking skills test in nursing.

    PubMed

    Shin, Sujin; Jung, Dukyoo; Kim, Sungeun

    2015-01-27

    The purpose of this study was to develop a revised version of the clinical critical thinking skills test (CCTS) and to subsequently validate its performance. This study is a secondary analysis of the CCTS. Data were obtained from a convenience sample of 284 college students in June 2011. Thirty items were analyzed using item response theory and test reliability was assessed. Test-retest reliability was measured using the results of 20 nursing college and graduate school students in July 2013. The content validity of the revised items was analyzed by calculating the degree of agreement between instrument developer intention in item development and the judgments of six experts. To analyze response process validity, qualitative data related to the response processes of nine nursing college students obtained through cognitive interviews were analyzed. Out of initial 30 items, 11 items were excluded after the analysis of difficulty and discrimination parameter. When the 19 items of the revised version of the CCTS were analyzed, levels of item difficulty were found to be relatively low and levels of discrimination were found to be appropriate or high. The degree of agreement between item developer intention and expert judgments equaled or exceeded 50%. From above results, evidence of the response process validity was demonstrated, indicating that subjects respondeds as intended by the test developer. The revised 19-item CCTS was found to have sufficient reliability and validity and will therefore represents a more convenient measurement of critical thinking ability.

  4. An Approach to Comprehensive and Sustainable Solar Wind Model Validation

    NASA Astrophysics Data System (ADS)

    Rastaetter, L.; MacNeice, P. J.; Mays, M. L.; Boblitt, J. M.; Wiegand, C.

    2017-12-01

    The number of models of the corona and inner heliosphere and of their updates and upgrades grows steadily, as does the number and character of the model inputs. Maintaining up to date validation of these models, in the face of this constant model evolution, is a necessary but very labor intensive activity. In the last year alone, both NASA's LWS program and the CCMC's ongoing support of model forecasting activities at NOAA SWPC have sought model validation reports on the quality of all aspects of the community's coronal and heliospheric models, including both ambient and CME related wind solutions at L1. In this presentation I will give a brief review of the community's previous model validation results of L1 wind representation. I will discuss the semi-automated web based system we are constructing at the CCMC to present comparative visualizations of all interesting aspects of the solutions from competing models.This system is designed to be easily queried to provide the essential comprehensive inputs to repeat andupdate previous validation studies and support extensions to them. I will illustrate this by demonstrating how the system is being used to support the CCMC/LWS Model Assessment Forum teams focused on the ambient and time dependent corona and solar wind, including CME arrival time and IMF Bz.I will also discuss plans to extend the system to include results from the Forum teams addressing SEP model validation.

  5. Validity for the simplified water displacement instrument to measure arm lymphedema as a result of breast cancer surgery.

    PubMed

    Sagen, Ase; Kåresen, Rolf; Skaane, Per; Risberg, May Arna

    2009-05-01

    To evaluate concurrent and construct validity for the Simplified Water Displacement Instrument (SWDI), an instrument for measuring arm volumes and arm lymphedema as a result of breast cancer surgery. Validity design. Hospital setting. Women (N=23; mean age, 64+/-11y) were examined 6 years after breast cancer surgery with axillary node dissection. Not applicable. The SWDI was included for measuring arm volumes to estimate arm lymphedema as a result of breast cancer surgery. A computed tomography (CT) scan was included to examine the cross-sectional areas (CSAs) in square millimeters for the subcutaneous tissue, for the muscle tissue, and for measuring tissue density in Hounsfield units. Magnetic resonance imaging (MRI) with T2-weighted sequences was included to show increased signal intensity in subcutaneous and muscle tissue areas. The affected arm volume measured by the SWDI was significantly correlated to the total CSA of the affected upper limb (R=.904) and also to the CSA of the subcutaneous tissue and muscles tissue (R=.867 and R=.725), respectively (P<.001). The CSA of the subcutaneous tissue for the upper limb was significantly larger compared with the control limb (11%). Tissue density measured in Hounsfield units did not correlate significantly with arm volume (P>.05). The affected arm volume was significantly larger (5%) than the control arm volume (P<.05). Five (22%) women had arm lymphedema defined as a 10% increase in the affected arm volume compared with the control arm volume, and an increased signal intensity was identified in all 5 women on MRI (T2-weighted, kappa=.777, P<.001). The SWDI showed high concurrent and construct validity as shown with significant correlations between the CSA (CT) of the subcutaneous and muscle areas of the affected limb and the affected arm volume (P>.001). There was a high agreement between those subjects who were diagnosed with arm lymphedema by using the SWDI and the increased signal intensity on MRI, with a kappa

  6. Enhancing Student Services at Lorain County Community College: Early Results from the Opening Doors Demonstration in Ohio

    ERIC Educational Resources Information Center

    Scrivener, Susan; Au, Jenny

    2007-01-01

    In 2003, MDRC and a consortium of funders launched the Opening Doors demonstration to test reforms in six community colleges aimed at helping students stay in school and earn credentials. This report presents early results from the Opening Doors program at Lorain County Community College in Elyria, Ohio. The program provided intensive advising and…

  7. Pooled results from five validation studies of dietary self-report instruments using recovery biomarkers for potassium and sodium intake

    USDA-ARS?s Scientific Manuscript database

    We have pooled data from five large validation studies of dietary self-report instruments that used recovery biomarkers as referents to assess food frequency questionnaires (FFQs) and 24-hour recalls. We reported on total potassium and sodium intakes, their densities, and their ratio. Results were...

  8. Zero Emission Bay Area (ZEBA) Fuel Cell Bus Demonstration : First Results Report

    DOT National Transportation Integrated Search

    2011-08-01

    In response to the California Air Resources Board (CARB) rule for transit agencies in the state, five San Francisco Bay Area transit agencies have joined together to demonstrate the largest fleet of fuel cell buses in the United States. The Zero Emis...

  9. The Fruit & Vegetable Screener in the 2000 California Health Interview Survey: Validation Results

    Cancer.gov

    In this study, multiple 24-hour recalls in conjunction with a measurement error model were used to assess validity. The screeners used in the EATS included additional foods and reported portion sizes.

  10. Personality traits in companion dogs-Results from the VIDOPET.

    PubMed

    Turcsán, Borbála; Wallis, Lisa; Virányi, Zsófia; Range, Friederike; Müller, Corsin A; Huber, Ludwig; Riemer, Stefanie

    2018-01-01

    Individual behavioural differences in pet dogs are of great interest from a basic and applied research perspective. Most existing dog personality tests have specific (practical) goals in mind and so focused only on a limited aspect of dogs' personality, such as identifying problematic (aggressive or fearful) behaviours, assessing suitability as working dogs, or improving the results of adoption. Here we aimed to create a comprehensive test of personality in pet dogs that goes beyond traditional practical evaluations by exposing pet dogs to a range of situations they might encounter in everyday life. The Vienna Dog Personality Test (VIDOPET) consists of 15 subtests and was performed on 217 pet dogs. A two-step data reduction procedure (principal component analysis on each subtest followed by an exploratory factor analysis on the subtest components) yielded five factors: Sociability-obedience, Activity-independence, Novelty seeking, Problem orientation, and Frustration tolerance. A comprehensive evaluation of reliability and validity measures demonstrated excellent inter- and intra-observer reliability and adequate internal consistency of all factors. Moreover the test showed good temporal consistency when re-testing a subsample of dogs after an average of 3.8 years-a considerably longer test-retest interval than assessed for any other dog personality test, to our knowledge. The construct validity of the test was investigated by analysing the correlations between the results of video coding and video rating methods and the owners' assessment via a dog personality questionnaire. The results demonstrated good convergent as well as discriminant validity. To conclude, the VIDOPET is not only a highly reliable and valid tool for measuring dog personality, but also the first test to show consistent behavioural traits related to problem solving ability and frustration tolerance in pet dogs.

  11. Personality traits in companion dogs—Results from the VIDOPET

    PubMed Central

    Wallis, Lisa; Virányi, Zsófia; Range, Friederike; Müller, Corsin A.; Huber, Ludwig; Riemer, Stefanie

    2018-01-01

    Individual behavioural differences in pet dogs are of great interest from a basic and applied research perspective. Most existing dog personality tests have specific (practical) goals in mind and so focused only on a limited aspect of dogs’ personality, such as identifying problematic (aggressive or fearful) behaviours, assessing suitability as working dogs, or improving the results of adoption. Here we aimed to create a comprehensive test of personality in pet dogs that goes beyond traditional practical evaluations by exposing pet dogs to a range of situations they might encounter in everyday life. The Vienna Dog Personality Test (VIDOPET) consists of 15 subtests and was performed on 217 pet dogs. A two-step data reduction procedure (principal component analysis on each subtest followed by an exploratory factor analysis on the subtest components) yielded five factors: Sociability-obedience, Activity-independence, Novelty seeking, Problem orientation, and Frustration tolerance. A comprehensive evaluation of reliability and validity measures demonstrated excellent inter- and intra-observer reliability and adequate internal consistency of all factors. Moreover the test showed good temporal consistency when re-testing a subsample of dogs after an average of 3.8 years—a considerably longer test-retest interval than assessed for any other dog personality test, to our knowledge. The construct validity of the test was investigated by analysing the correlations between the results of video coding and video rating methods and the owners’ assessment via a dog personality questionnaire. The results demonstrated good convergent as well as discriminant validity. To conclude, the VIDOPET is not only a highly reliable and valid tool for measuring dog personality, but also the first test to show consistent behavioural traits related to problem solving ability and frustration tolerance in pet dogs. PMID:29634747

  12. Youth Oriented Activity Trackers: Comprehensive Laboratory- and Field-Based Validation

    PubMed Central

    2017-01-01

    Background Commercial activity trackers are growing in popularity among adults and some are beginning to be marketed to children. There is, however, a paucity of independent research examining the validity of these devices to detect physical activity of different intensity levels. Objectives The purpose of this study was to determine the validity of the output from 3 commercial youth-oriented activity trackers in 3 phases: (1) orbital shaker, (2) structured indoor activities, and (3) 4 days of free-living activity. Methods Four units of each activity tracker (Movband [MB], Sqord [SQ], and Zamzee [ZZ]) were tested in an orbital shaker for 5-minutes at three frequencies (1.3, 1.9, and 2.5 Hz). Participants for Phase 2 (N=14) and Phase 3 (N=16) were 6-12 year old children (50% male). For Phase 2, participants completed 9 structured activities while wearing each tracker, the ActiGraph GT3X+ (AG) research accelerometer, and a portable indirect calorimetry system to assess energy expenditure (EE). For Phase 3, participants wore all 4 devices for 4 consecutive days. Correlation coefficients, linear models, and non-parametric statistics evaluated the criterion and construct validity of the activity tracker output. Results Output from all devices was significantly associated with oscillation frequency (r=.92-.99). During Phase 2, MB and ZZ only differentiated sedentary from light intensity (P<.01), whereas the SQ significantly differentiated among all intensity categories (all comparisons P<.01), similar to AG and EE. During Phase 3, AG counts were significantly associated with activity tracker output (r=.76, .86, and .59 for the MB, SQ, and ZZ, respectively). Conclusions Across study phases, the SQ demonstrated stronger validity than the MB and ZZ. The validity of youth-oriented activity trackers may directly impact their effectiveness as behavior modification tools, demonstrating a need for more research on such devices. PMID:28724509

  13. Groundwater Model Validation

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Ahmed E. Hassan

    2006-01-24

    Models have an inherent uncertainty. The difficulty in fully characterizing the subsurface environment makes uncertainty an integral component of groundwater flow and transport models, which dictates the need for continuous monitoring and improvement. Building and sustaining confidence in closure decisions and monitoring networks based on models of subsurface conditions require developing confidence in the models through an iterative process. The definition of model validation is postulated as a confidence building and long-term iterative process (Hassan, 2004a). Model validation should be viewed as a process not an end result. Following Hassan (2004b), an approach is proposed for the validation process ofmore » stochastic groundwater models. The approach is briefly summarized herein and detailed analyses of acceptance criteria for stochastic realizations and of using validation data to reduce input parameter uncertainty are presented and applied to two case studies. During the validation process for stochastic models, a question arises as to the sufficiency of the number of acceptable model realizations (in terms of conformity with validation data). Using a hierarchical approach to make this determination is proposed. This approach is based on computing five measures or metrics and following a decision tree to determine if a sufficient number of realizations attain satisfactory scores regarding how they represent the field data used for calibration (old) and used for validation (new). The first two of these measures are applied to hypothetical scenarios using the first case study and assuming field data consistent with the model or significantly different from the model results. In both cases it is shown how the two measures would lead to the appropriate decision about the model performance. Standard statistical tests are used to evaluate these measures with the results indicating they are appropriate measures for evaluating model realizations. The use of

  14. Measuring Work Functioning: Validity of a Weighted Composite Work Functioning Approach.

    PubMed

    Boezeman, Edwin J; Sluiter, Judith K; Nieuwenhuijsen, Karen

    2015-09-01

    To examine the construct validity of a weighted composite work functioning measurement approach. Workers (health-impaired/healthy) (n = 117) completed a composite measure survey that recorded four central work functioning aspects with existing scales: capacity to work, quality of work performance, quantity of work, and recovery from work. Previous derived weights reflecting the relative importance of these aspects of work functioning were used to calculate the composite weighted work functioning score of the workers. Work role functioning, productivity, and quality of life were used for validation. Correlations were calculated and norms applied to examine convergent and divergent construct validity. A t test was conducted and a norm applied to examine discriminative construct validity. Overall the weighted composite work functioning measure demonstrated construct validity. As predicted, the weighted composite score correlated (p < .001) strongly (r > .60) with work role functioning and productivity (convergent construct validity), and moderately (.30 < r < .60) with physical quality of life and less strongly than work role functioning and productivity with mental quality of life (divergent validity). Further, the weighted composite measure detected that health-impaired workers show with a large effect size (Cohen's d > .80) significantly worse work functioning than healthy workers (discriminative validity). The weighted composite work functioning measurement approach takes into account the relative importance of the different work functioning aspects and demonstrated good convergent, fair divergent, and good discriminative construct validity.

  15. Development and Validation of the Survey of Organizational Research Climate (SORC)

    PubMed Central

    Martinson, Brian C.; Thrush, Carol R.; Crain, A. Lauren

    2012-01-01

    Background Development and targeting efforts by academic organizations to effectively promote research integrity can be enhanced if they are able to collect reliable data to benchmark baseline conditions, to assess areas needing improvement, and to subsequently assess the impact of specific initiatives. To date, no standardized and validated tool has existed to serve this need. Methods A web- and mail-based survey was administered in the second half of 2009 to 2,837 randomly selected biomedical and social science faculty and postdoctoral fellows at 40 academic health centers in top-tier research universities in the United States. Measures included the Survey of Organizational Research Climate (SORC) as well as measures of perceptions of organizational justice. Results Exploratory and confirmatory factor analyses yielded seven subscales of organizational research climate, all of which demonstrated acceptable internal consistency (Cronbach’s α ranging from 0.81 to 0.87) and adequate test-retest reliability (Pearson r ranging from 0.72 to 0.83). A broad range of correlations between the seven subscales and five measures of organizational justice (unadjusted regression coefficients ranging from .13 to .95) document both construct and discriminant validity of the instrument. Conclusions The SORC demonstrates good internal (alpha) and external reliability (test-retest) as well as both construct and discriminant validity. PMID:23096775

  16. Validation of Clinical Testing for Warfarin Sensitivity

    PubMed Central

    Langley, Michael R.; Booker, Jessica K.; Evans, James P.; McLeod, Howard L.; Weck, Karen E.

    2009-01-01

    Responses to warfarin (Coumadin) anticoagulation therapy are affected by genetic variability in both the CYP2C9 and VKORC1 genes. Validation of pharmacogenetic testing for warfarin responses includes demonstration of analytical validity of testing platforms and of the clinical validity of testing. We compared four platforms for determining the relevant single nucleotide polymorphisms (SNPs) in both CYP2C9 and VKORC1 that are associated with warfarin sensitivity (Third Wave Invader Plus, ParagonDx/Cepheid Smart Cycler, Idaho Technology LightCycler, and AutoGenomics Infiniti). Each method was examined for accuracy, cost, and turnaround time. All genotyping methods demonstrated greater than 95% accuracy for identifying the relevant SNPs (CYP2C9 *2 and *3; VKORC1 −1639 or 1173). The ParagonDx and Idaho Technology assays had the shortest turnaround and hands-on times. The Third Wave assay was readily scalable to higher test volumes but had the longest hands-on time. The AutoGenomics assay interrogated the largest number of SNPs but had the longest turnaround time. Four published warfarin-dosing algorithms (Washington University, UCSF, Louisville, and Newcastle) were compared for accuracy for predicting warfarin dose in a retrospective analysis of a local patient population on long-term, stable warfarin therapy. The predicted doses from both the Washington University and UCSF algorithms demonstrated the best correlation with actual warfarin doses. PMID:19324988

  17. A demonstrator for an incoherent Doppler wind lidar receiver

    NASA Astrophysics Data System (ADS)

    Fabre, F.; Marini, A.; Sidler, Thomas C.; Morancais, Didier; Fongy, G.; Vidal, Ph.

    2018-04-01

    The knowledge of wind fields for a global terrestrial coverage and accurate altitude sampling is one of the main keys for improvement of meteorological predictions and general understanding of atmosphere behaviour. The best way to recover this information is remote sensing from space using low Earth orbit satellites. The measurement principle is to analyse the Doppler shift of the flux emitted by the space instrument and backscattered by the atmosphere. One of the most promising principle for Doppler shift measurement is the direct detection which does not need local oscillators. what significantly simplifies the design of such a space-borne receiver. ESA-ESTEC initiated at early 95' a programme called "lncoherent Doppler Wind Lidar (IDWL) technologies" for the study and bread-boarding phase. MMS won this contract proposing an original concept based on the use of a Fizeau high resolution interferometer working in the UV band. coupled with an intensified CCD. This concept is patented by MMS, as well as the special CCD timing sequence that will be depicted below. The programme begun by a study of the space-borne instrument in order to identify main constraints and define the receiver as could be for a flight model. A detailed performance model was established and parametric analysis allowed to optimise the concept in order to reach required performances. This study phase finally provided the definition of a bread-board for expected performances demonstration. Moreover, the Laser Signal Simulator (LSS) which is used to simulate the Lidar echo in term of amplitude as well as frequency modulation was defined at this step. The performances of this test support equipment are of main importance for the validation of the demonstrator design and performances. The second part of the study aimed at defining the derailed design of the demonstrator and associated test support equipment as well as initiating preliminary validation experiments on most critical technologies, like

  18. Reliability and Validity of Ambulatory Cognitive Assessments

    PubMed Central

    Sliwinski, Martin J.; Mogle, Jacqueline A.; Hyun, Jinshil; Munoz, Elizabeth; Smyth, Joshua M.; Lipton, Richard B.

    2017-01-01

    Mobile technologies are increasingly used to measure cognitive function outside of traditional clinic and laboratory settings. Although ambulatory assessments of cognitive function conducted in people’s natural environments offer potential advantages over traditional assessment approaches, the psychometrics of cognitive assessment procedures have been understudied. We evaluated the reliability and construct validity of ambulatory assessments of working memory and perceptual speed administered via smartphones as part of an ecological momentary assessment (EMA) protocol in a diverse adult sample (N=219). Results indicated excellent between-person reliability (≥.97) for average scores, and evidence of reliable within-person variability across measurement occasions (.41–.53). The ambulatory tasks also exhibited construct validity, as evidence by their loadings on working memory and perceptual speed factors defined by the in-lab assessments. Our findings demonstrate that averaging across brief cognitive assessments made in uncontrolled naturalistic settings provide measurements that are comparable in reliability to assessments made in controlled laboratory environments. PMID:27084835

  19. Urdu translation of the Hamilton Rating Scale for Depression: Results of a validation study.

    PubMed

    Hashmi, Ali M; Naz, Shahana; Asif, Aftab; Khawaja, Imran S

    2016-01-01

    To develop a standardized validated version of the Hamilton Rating Scale for Depression (HAM-D) in Urdu. After translation of the HAM-D into the Urdu language following standard guidelines, the final Urdu version (HAM-D-U) was administered to 160 depressed outpatients. Inter-item correlation was assessed by calculating Cronbach alpha. Correlation between HAM-D-U scores at baseline and after a 2-week interval was evaluated for test-retest reliability. Moreover, scores of two clinicians on HAM-D-U were compared for inter-rater reliability. For establishing concurrent validity, scores of HAM-D-U and BDI-U were compared by using Spearman correlation coefficient. The study was conducted at Mayo Hospital, Lahore, from May to December 2014. The Cronbach alpha for HAM-D-U was 0.71. Composite scores for HAM-D-U at baseline and after a 2-week interval were also highly correlated with each other (Spearman correlation coefficient 0.83, p-value < 0.01) indicating good test-retest reliability. Composite scores for HAM-D-U and BDI-U were positively correlated with each other (Spearman correlation coefficient 0.85, p < 0.01) indicating good concurrent validity. Scores of two clinicians for HAM-D-U were also positively correlated (Spearman correlation coefficient 0.82, p-value < 0.01) indicated good inter-rater reliability. The HAM-D-U is a valid and reliable instrument for the assessment of Depression. It shows good inter-rater and test-retest reliability. The HAM-D-U can be a tool either for clinical management or research.

  20. Translation, Cultural Adaptation and Validation of the Simple Shoulder Test to Spanish

    PubMed Central

    Arcuri, Francisco; Barclay, Fernando; Nacul, Ivan

    2015-01-01

    Background: The validation of widely used scales facilitates the comparison across international patient samples. Objective: The objective was to translate, culturally adapt and validate the Simple Shoulder Test into Argentinian Spanish. Methods: The Simple Shoulder Test was translated from English into Argentinian Spanish by two independent translators, translated back into English and evaluated for accuracy by an expert committee to correct the possible discrepancies. It was then administered to 50 patients with different shoulder conditions.Psycometric properties were analyzed including internal consistency, measured with Cronbach´s Alpha, test-retest reliability at 15 days with the interclass correlation coefficient. Results: The internal consistency, validation, was an Alpha of 0,808, evaluated as good. The test-retest reliability index as measured by intra-class correlation coefficient (ICC) was 0.835, evaluated as excellent. Conclusion: The Simple Shoulder Test translation and it´s cultural adaptation to Argentinian-Spanish demonstrated adequate internal reliability and validity, ultimately allowing for its use in the comparison with international patient samples.

  1. Development and validation of Triarchic construct scales from the psychopathic personality inventory.

    PubMed

    Hall, Jason R; Drislane, Laura E; Patrick, Christopher J; Morano, Mario; Lilienfeld, Scott O; Poythress, Norman G

    2014-06-01

    The Triarchic model of psychopathy describes this complex condition in terms of distinct phenotypic components of boldness, meanness, and disinhibition. Brief self-report scales designed specifically to index these psychopathy facets have thus far demonstrated promising construct validity. The present study sought to develop and validate scales for assessing facets of the Triarchic model using items from a well-validated existing measure of psychopathy-the Psychopathic Personality Inventory (PPI). A consensus-rating approach was used to identify PPI items relevant to each Triarchic facet, and the convergent and discriminant validity of the resulting PPI-based Triarchic scales were evaluated in relation to multiple criterion variables (i.e., other psychopathy inventories, antisocial personality disorder features, personality traits, psychosocial functioning) in offender and nonoffender samples. The PPI-based Triarchic scales showed good internal consistency and related to criterion variables in ways consistent with predictions based on the Triarchic model. Findings are discussed in terms of implications for conceptualization and assessment of psychopathy.

  2. Development and Validation of Triarchic Construct Scales from the Psychopathic Personality Inventory

    PubMed Central

    Hall, Jason R.; Drislane, Laura E.; Patrick, Christopher J.; Morano, Mario; Lilienfeld, Scott O.; Poythress, Norman G.

    2014-01-01

    The Triarchic model of psychopathy describes this complex condition in terms of distinct phenotypic components of boldness, meanness, and disinhibition. Brief self-report scales designed specifically to index these psychopathy facets have thus far demonstrated promising construct validity. The present study sought to develop and validate scales for assessing facets of the Triarchic model using items from a well-validated existing measure of psychopathy—the Psychopathic Personality Inventory (PPI). A consensus rating approach was used to identify PPI items relevant to each Triarchic facet, and the convergent and discriminant validity of the resulting PPI-based Triarchic scales were evaluated in relation to multiple criterion variables (i.e., other psychopathy inventories, antisocial personality disorder features, personality traits, psychosocial functioning) in offender and non-offender samples. The PPI-based Triarchic scales showed good internal consistency and related to criterion variables in ways consistent with predictions based on the Triarchic model. Findings are discussed in terms of implications for conceptualization and assessment of psychopathy. PMID:24447280

  3. A simple model to demonstrate the electronic apex locator.

    PubMed

    Tinaz, A C; Alaçam, T; Topuz, O

    2002-11-01

    To describe and evaluate a newly developed model for demonstrating and teaching the use of electronic apex locators. A phantom model, master jaw model and extracted human teeth were used to construct the demonstration model with alginate impression material as the periapical conductive medium. The model was validated in a series of length determinations with apical foramina enlarged to 0.20, 0.30 and 0.45 mm diameter, and the stability of the model was evaluated up to 45 h after construction. All evaluations were conducted with the Root ZX apex locator with 2.65 and 5.25% NaOCl in the canals. Most length measurements were within 1 mm of actual root length (range: -2.2 to +0.21 mm) and did not change significantly over 45 h for teeth with foramina of 0.3 mm or less. Measurements for teeth with wide (0.45 mm) apices were stable up to 28 h. NaOCl concentration did not significantly affect the readings. A simple, inexpensive model can be manufactured from plastic dental jaws, natural teeth and alginate impression material to demonstrate electronic working length measurement. The model is stable for many hours and provides consistent results with different concentrations of NaOCl in the canal and various apical diameters. The model is a useful teaching aid but needs further evaluation and refinement before use in research applications.

  4. INITIAL TEST RESULTS OF THE LIMESTONE INJECTION MULTISTAGE BURNER (LIMB) DEMONSTRATION PROJECT

    EPA Science Inventory

    The paper discusses SO2 removal efficiency and low-NOx burner performance obtained during short term tests, as well as the impact of LIMB ash on electrostatic precipitator (ESP) performance at Ohio Edison's Edgewater Station. Project goals are to demonstrate 50% or more SO2 remov...

  5. Toward DNA-based facial composites: preliminary results and validation.

    PubMed

    Claes, Peter; Hill, Harold; Shriver, Mark D

    2014-11-01

    The potential of constructing useful DNA-based facial composites is forensically of great interest. Given the significant identity information coded in the human face these predictions could help investigations out of an impasse. Although, there is substantial evidence that much of the total variation in facial features is genetically mediated, the discovery of which genes and gene variants underlie normal facial variation has been hampered primarily by the multipartite nature of facial variation. Traditionally, such physical complexity is simplified by simple scalar measurements defined a priori, such as nose or mouth width or alternatively using dimensionality reduction techniques such as principal component analysis where each principal coordinate is then treated as a scalar trait. However, as shown in previous and related work, a more impartial and systematic approach to modeling facial morphology is available and can facilitate both the gene discovery steps, as we recently showed, and DNA-based facial composite construction, as we show here. We first use genomic ancestry and sex to create a base-face, which is simply an average sex and ancestry matched face. Subsequently, the effects of 24 individual SNPs that have been shown to have significant effects on facial variation are overlaid on the base-face forming the predicted-face in a process akin to a photomontage or image blending. We next evaluate the accuracy of predicted faces using cross-validation. Physical accuracy of the facial predictions either locally in particular parts of the face or in terms of overall similarity is mainly determined by sex and genomic ancestry. The SNP-effects maintain the physical accuracy while significantly increasing the distinctiveness of the facial predictions, which would be expected to reduce false positives in perceptual identification tasks. To the best of our knowledge this is the first effort at generating facial composites from DNA and the results are preliminary

  6. Development and validation of the primary care team dynamics survey.

    PubMed

    Song, Hummy; Chien, Alyna T; Fisher, Josephine; Martin, Julia; Peters, Antoinette S; Hacker, Karen; Rosenthal, Meredith B; Singer, Sara J

    2015-06-01

    To develop and validate a survey instrument designed to measure team dynamics in primary care. We studied 1,080 physician and nonphysician health care professionals working at 18 primary care practices participating in a learning collaborative aimed at improving team-based care. We developed a conceptual model and administered a cross-sectional survey addressing team dynamics, and we assessed reliability and discriminant validity of survey factors and the overall survey's goodness-of-fit using structural equation modeling. We administered the survey between September 2012 and March 2013. Overall response rate was 68 percent (732 respondents). Results support a seven-factor model of team dynamics, suggesting that conditions for team effectiveness, shared understanding, and three supportive processes are associated with acting and feeling like a team and, in turn, perceived team effectiveness. This model demonstrated adequate fit (goodness-of-fit index: 0.91), scale reliability (Cronbach's alphas: 0.71-0.91), and discriminant validity (average factor correlations: 0.49). It is possible to measure primary care team dynamics reliably using a 29-item survey. This survey may be used in ambulatory settings to study teamwork and explore the effect of efforts to improve team-based care. Future studies should demonstrate the importance of team dynamics for markers of team effectiveness (e.g., work satisfaction, care quality, clinical outcomes). © Health Research and Educational Trust.

  7. Construct Validity and Reliability of College Students' Responses to the Reasons for Smoking Scale

    ERIC Educational Resources Information Center

    Fiala, Kelly Ann; D'Abundo, Michelle Lee; Marinaro, Laura Marie

    2010-01-01

    When utilizing self-assessments to determine motives for health behaviors, it is essential that the resulting data demonstrate sound psychometric properties. The purpose of this research was to assess the reliability and construct validity of college students' responses to the Reasons for Smoking Scale (RFS). Confirmatory factor analyses and…

  8. Validation of the Oxford Participation and Activities Questionnaire

    PubMed Central

    Morley, David; Dummett, Sarah; Kelly, Laura; Dawson, Jill; Fitzpatrick, Ray; Jenkinson, Crispin

    2016-01-01

    Purpose There is growing interest in the management of long-term conditions and in keeping people active and participating in the community. Testing the effectiveness of interventions that aim to affect activities and participation can be challenging without a well-developed, valid, and reliable instrument. This study therefore aims to develop a patient-reported outcome measure, the Oxford Participation and Activities Questionnaire (Ox-PAQ), which is theoretically grounded in the World Health Organization’s International Classification of Functioning, Disability, and Health (ICF) and fully compliant with current best practice guidelines. Methods Questionnaire items generated from patient interviews and based on the nine chapters of the ICF were administered by postal survey to 386 people with three neurological conditions: motor neuron disease, multiple sclerosis, and Parkinson’s disease. Participants also completed the Medical Outcomes Study (MOS) 36-Item Short Form Health Survey (SF-36) and EQ-5D-5L. Results Thus, 334 participants completed the survey, a response rate of 86.5%. Factor analysis techniques identified three Ox-PAQ domains, consisting of 23 items, accounting for 72.8% of variance. Internal reliability for the three domains was high (Cronbach’s α: 0.81–0.96), as was test–retest reliability (intraclass correlation: 0.83–0.92). Concurrent validity was demonstrated through highly significant relationships with relevant domains of the MOS SF-36 and the EQ- 5D-5L. Assessment of known-groups validity identified significant differences in Ox-PAQ scores among the three conditions included in the survey. Conclusion Results suggest that the Ox-PAQ is a valid and reliable measure of participation and activity. The measure will now be validated in a range of further conditions, and additional properties, such as responsiveness, will also be assessed in the next phase of the instrument’s development. PMID:27366108

  9. Using Focus Groups to Validate a Pharmacy Vaccination Training Program.

    PubMed

    Bushell, Mary; Morrissey, Hana; Ball, Patrick

    2015-06-12

    Introduction: Focus group methodology is commonly used to quickly collate, integrated views from a variety of different stakeholders. This paper provides an example of how focus groups can be employed to collate expert opinion informing amendments on a newly developed training program for integration into undergraduate pharmacy curricula. Materials and methods: Four focus groups were conducted, across three continents, to determine the appropriateness and reliability of a developed vaccination training program with nested injection skills training. All focus groups were comprised of legitimate experts in the field of vaccination, medicine and/or pharmacy. Results: Themes that emerged across focus groups informed amendments giving rise to a validated version of a training program. Discussion : The rigorous validation of the vaccination training program offers generalizable lessons to inform the design and validation of future training programs intended for the health sector and or pharmacy curricula. Using the knowledge and experience of focus group participants fostered collaborative problem solving and validation of material and concept development. The group dynamics of a focus group allowed synthesis of feedback in an inter-professional manner. Conclusions : This paper provides a demonstration of how focus groups can be structured and used by health researchers to validate a newly developed training program.

  10. Critical validation studies of neurofeedback.

    PubMed

    Gruzelier, John; Egner, Tobias

    2005-01-01

    The field of neurofeedback training has proceeded largely without validation. In this article the authors review studies directed at validating sensory motor rhythm, beta and alpha-theta protocols for improving attention, memory, and music performance in healthy participants. Importantly, benefits were demonstrable with cognitive and neurophysiologic measures that were predicted on the basis of regression models of learning to enhance sensory motor rhythm and beta activity. The first evidence of operant control over the alpha-theta ratio is provided, together with remarkable improvements in artistic aspects of music performance equivalent to two class grades in conservatory students. These are initial steps in providing a much needed scientific basis to neurofeedback.

  11. Teacher and Principal Survey Results in the National Preventive Dentistry Demonstration Program.

    ERIC Educational Resources Information Center

    Klein, Stephen P.; And Others

    The National Preventive Dentistry Demonstration Program was conducted to assess the costs and benefits of combinations of school-based preventive dental care procedures. The program involved almost 30,000 elementary school children from 10 sites across the country. Classroom procedures, such as weekly fluoride mouthrinse, were administered or…

  12. Autonomous formation flying based on GPS — PRISMA flight results

    NASA Astrophysics Data System (ADS)

    D'Amico, Simone; Ardaens, Jean-Sebastien; De Florio, Sergio

    2013-01-01

    This paper presents flight results from the early harvest of the Spaceborne Autonomous Formation Flying Experiment (SAFE) conducted in the frame of the Swedish PRISMA technology demonstration mission. SAFE represents one of the first demonstrations in low Earth orbit of an advanced guidance, navigation and control system for dual-spacecraft formations. Innovative techniques based on differential GPS-based navigation and relative orbital elements control are validated and tuned in orbit to fulfill the typical requirements of future distributed scientific instruments for remote sensing.

  13. SCIAMACHY validation by aircraft remote sensing: design, execution, and first measurement results of the SCIA-VALUE mission

    NASA Astrophysics Data System (ADS)

    Fix, A.; Ehret, G.; Flentje, H.; Poberaj, G.; Gottwald, M.; Finkenzeller, H.; Bremer, H.; Bruns, M.; Burrows, J. P.; Kleinböhl, A.; Küllmann, H.; Kuttippurath, J.; Richter, A.; Wang, P.; Heue, K.-P.; Platt, U.; Pundt, I.; Wagner, T.

    2005-05-01

    For the first time three different remote sensing instruments - a sub-millimeter radiometer, a differential optical absorption spectrometer in the UV-visible spectral range, and a lidar - were deployed aboard DLR's meteorological research aircraft Falcon 20 to validate a large number of SCIAMACHY level 2 and off-line data products such as O3, NO2, N2O, BrO, OClO, H2O, aerosols, and clouds. Within two validation campaigns of the SCIA-VALUE mission (SCIAMACHY VALidation and Utilization Experiment) extended latitudinal cross-sections stretching from polar regions to the tropics as well as longitudinal cross sections at polar latitudes at about 70° N and the equator were generated. This contribution gives an overview over the campaigns performed and reports on the observation strategy for achieving the validation goals. We also emphasize the synergetic use of the novel set of aircraft instrumentation and the usefulness of this innovative suite of remote sensing instruments for satellite validation.

  14. Wide Angle Imaging Lidar (WAIL): Theory of Operation and Results from Cross-Platform Validation at the ARM Southern Great Plains Site

    NASA Astrophysics Data System (ADS)

    Polonsky, I. N.; Davis, A. B.; Love, S. P.

    2004-05-01

    WAIL was designed to determine physical and geometrical characteristics of optically thick clouds using the off-beam component of the lidar return that can be accurately modeled within the 3D photon diffusion approximation. The theory shows that the WAIL signal depends not only on the cloud optical characteristics (phase function, extinction and scattering coefficients) but also on the outer thickness of the cloud layer. This makes it possible to estimate the mean optical and geometrical thicknesses of the cloud. The comparison with Monte Carlo simulation demonstrates the high accuracy of the diffusion approximation for moderately to very dense clouds. During operation WAIL is able to collect a complete data set from a cloud every few minutes, with averaging over horizontal scale of a kilometer or so. In order to validate WAIL's ability to deliver cloud properties, the LANL instrument was deployed as a part of the THickness from Off-beam Returns (THOR) validation IOP. The goal was to probe clouds above the SGP CART site at night in March 2002 from below (WAIL and ARM instruments) and from NASA's P3 aircraft (carrying THOR, the GSFC counterpart of WAIL) flying above the clouds. The permanent cloud instruments we used to compare with the results obtained from WAIL were ARM's laser ceilometer, micro-pulse lidar (MPL), millimeter-wavelength cloud radar (MMCR), and micro-wave radiometer (MWR). The comparison shows that, in spite of an unusually low cloud ceiling, an unfavorable observation condition for WAIL's present configuration, cloud properties obtained from the new instrument are in good agreement with their counterparts obtained by other instruments. So WAIL can duplicate, at least for single-layer clouds, the cloud products of the MWR and MMCR together. But WAIL does this with green laser light, which is far more representative than microwaves of photon transport processes at work in the climate system.

  15. A study for active control research and validation using the Total In-Flight Simulator (TIFS) aircraft

    NASA Technical Reports Server (NTRS)

    Chen, R. T. N.; Daughaday, H.; Andrisani, D., II; Till, R. D.; Weingarten, N. C.

    1975-01-01

    The results of a feasibility study and preliminary design for active control research and validation using the Total In-Flight Simulator (TIFS) aircraft are documented. Active control functions which can be demonstrated on the TIFS aircraft and the cost of preparing, equipping, and operating the TIFS aircraft for active control technology development are determined. It is shown that the TIFS aircraft is as a suitable test bed for inflight research and validation of many ACT concepts.

  16. Computationally efficient confidence intervals for cross-validated area under the ROC curve estimates.

    PubMed

    LeDell, Erin; Petersen, Maya; van der Laan, Mark

    In binary classification problems, the area under the ROC curve (AUC) is commonly used to evaluate the performance of a prediction model. Often, it is combined with cross-validation in order to assess how the results will generalize to an independent data set. In order to evaluate the quality of an estimate for cross-validated AUC, we obtain an estimate of its variance. For massive data sets, the process of generating a single performance estimate can be computationally expensive. Additionally, when using a complex prediction method, the process of cross-validating a predictive model on even a relatively small data set can still require a large amount of computation time. Thus, in many practical settings, the bootstrap is a computationally intractable approach to variance estimation. As an alternative to the bootstrap, we demonstrate a computationally efficient influence curve based approach to obtaining a variance estimate for cross-validated AUC.

  17. Computationally efficient confidence intervals for cross-validated area under the ROC curve estimates

    PubMed Central

    Petersen, Maya; van der Laan, Mark

    2015-01-01

    In binary classification problems, the area under the ROC curve (AUC) is commonly used to evaluate the performance of a prediction model. Often, it is combined with cross-validation in order to assess how the results will generalize to an independent data set. In order to evaluate the quality of an estimate for cross-validated AUC, we obtain an estimate of its variance. For massive data sets, the process of generating a single performance estimate can be computationally expensive. Additionally, when using a complex prediction method, the process of cross-validating a predictive model on even a relatively small data set can still require a large amount of computation time. Thus, in many practical settings, the bootstrap is a computationally intractable approach to variance estimation. As an alternative to the bootstrap, we demonstrate a computationally efficient influence curve based approach to obtaining a variance estimate for cross-validated AUC. PMID:26279737

  18. Nursing Care Interpersonal Relationship Questionnaire: elaboration and validation 1

    PubMed Central

    Borges, José Wicto Pereira; Moreira, Thereza Maria Magalhães; de Andrade, Dalton Franscisco

    2018-01-01

    ABSTRACT Objective: to elaborate an instrument for the measurement of the interpersonal relationship in nursing care through the Item Response Theory, and the validation thereof. Method: methodological study, which followed the three poles of psychometry: theoretical, empirical and analytical. The Nursing Care Interpersonal Relationship Questionnaire was developed in light of the Imogene King’s Interpersonal Conceptual Model and the psychometric properties were studied through the Item Response Theory in a sample of 950 patients attended in Primary, Secondary and Tertiary Health Care. Results: the final instrument consisted of 31 items, with Cronbach’s alpha of 0.90 and McDonald’s Omega of 0.92. The parameters of the Item Response Theory demonstrated high discrimination in 28 items, being developed a five-level interpretive scale. At the first level, the communication process begins, gaining a wealth of interaction. Subsequent levels demonstrate qualitatively the points of effectiveness of the interpersonal relationship with the involvement of behaviors related to the concepts of transaction and interaction, followed by the concept of role. Conclusion: the instrument was created and proved to be consistent to measure interpersonal relationship in nursing care, as it presented adequate reliability and validity parameters. PMID:29319743

  19. Demonstration of disinfection procedure for the development of accurate blood glucose meters in accordance with ISO 15197:2013

    PubMed Central

    Lin, Wen-Ye; Chang, Jung-Tzu; Chu, Chun-Feng

    2017-01-01

    Despite measures to reduce disease transmission, a risk can occur when blood glucose meters (BGMs) are used on multiple individuals or by caregivers assisting a patient. The laboratory and in-clinic performance of a BGM system before and after disinfection should be demonstrated to guarantee accurate readings and reliable control of blood glucose (BG) for patients. In this study, an effective disinfection procedure, conducting wiping 10 times to assure a one minute contact time of the disinfectant on contaminated surface, was first demonstrated using test samples of the meter housing materials, including acrylonitrile butadiene styrene (ABS), polymethyl methacrylate (PMMA), and polycarbonate (PC), in accordance with ISO 15197:2013. After bench studies comprising 10,000 disinfection cycles, the elemental compositions of the disinfected ABS, PMMA, and PC samples were almost the same as in the original samples, as indicated by electron spectroscopy for chemical analysis. Subsequently, the validated disinfection procedure was then directly applied to disinfect 5 commercial BGM systems composed of ABS, PMMA, or PC to observe the effect of the validated disinfection procedure on meter accuracy. The results of HBsAg values after treatment with HBV sera and disinfectant wipes for each material were less than the LoD of each material of 0.020 IU/mL. Before and after the multiple disinfection cycles, 900 of 900 samples (100%) were within the system accuracy requirements of ISO 15197:2013. All of the systems showed high performance before and after the series of disinfection cycles and met the ISO 15197:2013 requirements. In addition, our results demonstrated multiple cleaning and disinfection cycles that represented normal use over the lifetime of a meter of 3–5 years. Our validated cleaning and disinfection procedure can be directly applied to other registered disinfectants for cleaning commercial BGM products in the future. PMID:28683148

  20. Demonstration of disinfection procedure for the development of accurate blood glucose meters in accordance with ISO 15197:2013.

    PubMed

    Lin, Shu-Ping; Lin, Wen-Ye; Chang, Jung-Tzu; Chu, Chun-Feng

    2017-01-01

    Despite measures to reduce disease transmission, a risk can occur when blood glucose meters (BGMs) are used on multiple individuals or by caregivers assisting a patient. The laboratory and in-clinic performance of a BGM system before and after disinfection should be demonstrated to guarantee accurate readings and reliable control of blood glucose (BG) for patients. In this study, an effective disinfection procedure, conducting wiping 10 times to assure a one minute contact time of the disinfectant on contaminated surface, was first demonstrated using test samples of the meter housing materials, including acrylonitrile butadiene styrene (ABS), polymethyl methacrylate (PMMA), and polycarbonate (PC), in accordance with ISO 15197:2013. After bench studies comprising 10,000 disinfection cycles, the elemental compositions of the disinfected ABS, PMMA, and PC samples were almost the same as in the original samples, as indicated by electron spectroscopy for chemical analysis. Subsequently, the validated disinfection procedure was then directly applied to disinfect 5 commercial BGM systems composed of ABS, PMMA, or PC to observe the effect of the validated disinfection procedure on meter accuracy. The results of HBsAg values after treatment with HBV sera and disinfectant wipes for each material were less than the LoD of each material of 0.020 IU/mL. Before and after the multiple disinfection cycles, 900 of 900 samples (100%) were within the system accuracy requirements of ISO 15197:2013. All of the systems showed high performance before and after the series of disinfection cycles and met the ISO 15197:2013 requirements. In addition, our results demonstrated multiple cleaning and disinfection cycles that represented normal use over the lifetime of a meter of 3-5 years. Our validated cleaning and disinfection procedure can be directly applied to other registered disinfectants for cleaning commercial BGM products in the future.

  1. Development and validation of the Overall Depression Severity and Impairment Scale.

    PubMed

    Bentley, Kate H; Gallagher, Matthew W; Carl, Jenna R; Barlow, David H

    2014-09-01

    The need to capture severity and impairment of depressive symptomatology is widespread. Existing depression scales are lengthy and largely focus on individual symptoms rather than resulting impairment. The Overall Depression Severity and Impairment Scale (ODSIS) is a 5-item, continuous measure designed for use across heterogeneous mood disorders and with subthreshold depressive symptoms. This study examined the psychometric properties of the ODSIS in outpatients in a clinic for emotional disorders (N = 100), undergraduate students (N = 566), and community-based adults (N = 189). Internal consistency, latent structure, item response theory, classification accuracy, convergent and discriminant validity, and differential item functioning analyses were conducted. ODSIS scores exhibited excellent internal consistency, and confirmatory factor analyses supported a unidimensional structure. Item response theory results demonstrated that the ODSIS provides more information about individuals with high levels of depression than those with low levels of depression. Responses on the ODSIS discriminated well between individuals with and without a mood disorder and depression-related severity across clinical and subclinical levels. A cut score of 8 correctly classified 82% of outpatients as with or without a mood disorder; it evidenced a favorable balance of sensitivity and specificity and of positive and negative predictive values. The ODSIS demonstrated good convergent and discriminant validity, and results indicate that items function similarly across clinical and nonclinical samples. Overall, findings suggest that the ODSIS is a valid tool for measuring depression-related severity and impairment. The brevity and ease of use of the ODSIS support its utility for screening and monitoring treatment response across a variety of settings. PsycINFO Database Record (c) 2014 APA, all rights reserved.

  2. Dynamic Forces in Spur Gears - Measurement, Prediction, and Code Validation

    NASA Technical Reports Server (NTRS)

    Oswald, Fred B.; Townsend, Dennis P.; Rebbechi, Brian; Lin, Hsiang Hsi

    1996-01-01

    Measured and computed values for dynamic loads in spur gears were compared to validate a new version of the NASA gear dynamics code DANST-PC. Strain gage data from six gear sets with different tooth profiles were processed to determine the dynamic forces acting between the gear teeth. Results demonstrate that the analysis code successfully simulates the dynamic behavior of the gears. Differences between analysis and experiment were less than 10 percent under most conditions.

  3. Measurements of Humidity in the Atmosphere and Validation Experiments (MOHAVE)-2009: overview of campaign operations and results

    NASA Astrophysics Data System (ADS)

    Leblanc, T.; Walsh, T. D.; McDermid, I. S.; Toon, G. C.; Blavier, J.-F.; Haines, B.; Read, W. G.; Herman, B.; Fetzer, E.; Sander, S.; Pongetti, T.; Whiteman, D. N.; McGee, T. G.; Twigg, L.; Sumnicht, G.; Venable, D.; Calhoun, M.; Dirisu, A.; Hurst, D.; Jordan, A.; Hall, E.; Miloshevich, L.; Vömel, H.; Straub, C.; Kampfer, N.; Nedoluha, G. E.; Gomez, R. M.; Holub, K.; Gutman, S.; Braun, J.; Vanhove, T.; Stiller, G.; Hauchecorne, A.

    2011-05-01

    The Measurements of Humidity in the Atmosphere and Validation Experiment (MOHAVE) 2009 campaign took place on 11-27 October 2009 at the JPL Table Mountain Facility in California (TMF). The main objectives of the campaign were to (1) validate the water vapor measurements of several instruments, including, three Raman lidars, two microwave radiometers, two Fourier-Transform spectrometers, and two GPS receivers (column water), (2) cover water vapor measurements from the ground to the mesopause without gaps, and (3) study upper tropospheric humidity variability at timescales varying from a few minutes to several days. A total of 58 radiosondes and 20 Frost-Point hygrometer sondes were launched. Two types of radiosondes were used during the campaign. Non negligible differences in the readings between the two radiosonde types used (Vaisala RS92 and InterMet iMet-1) made a small, but measurable impact on the derivation of water vapor mixing ratio by the Frost-Point hygrometers. As observed in previous campaigns, the RS92 humidity measurements remained within 5 % of the Frost-point in the lower and mid-troposphere, but were too dry in the upper troposphere. Over 270 h of water vapor measurements from three Raman lidars (JPL and GSFC) were compared to RS92, CFH, and NOAA-FPH. The JPL lidar profiles reached 20 km when integrated all night, and 15 km when integrated for 1 h. Excellent agreement between this lidar and the frost-point hygrometers was found throughout the measurement range, with only a 3 % (0.3 ppmv) mean wet bias for the lidar in the upper troposphere and lower stratosphere (UTLS). The other two lidars provided satisfactory results in the lower and mid-troposphere (2-5 % wet bias over the range 3-10 km), but suffered from contamination by fluorescence (wet bias ranging from 5 to 50 % between 10 km and 15 km), preventing their use as an independent measurement in the UTLS. The comparison between all available stratospheric sounders allowed to identify only the

  4. Measurements of Humidity in the Atmosphere and Validation Experiments (MOHAVE)-2009: overview of campaign operations and results

    NASA Astrophysics Data System (ADS)

    Leblanc, T.; Walsh, T. D.; McDermid, I. S.; Toon, G. C.; Blavier, J.-F.; Haines, B.; Read, W. G.; Herman, B.; Fetzer, E.; Sander, S.; Pongetti, T.; Whiteman, D. N.; McGee, T. G.; Twigg, L.; Sumnicht, G.; Venable, D.; Calhoun, M.; Dirisu, A.; Hurst, D.; Jordan, A.; Hall, E.; Miloshevich, L.; Vömel, H.; Straub, C.; Kampfer, N.; Nedoluha, G. E.; Gomez, R. M.; Holub, K.; Gutman, S.; Braun, J.; Vanhove, T.; Stiller, G.; Hauchecorne, A.

    2011-12-01

    The Measurements of Humidity in the Atmosphere and Validation Experiment (MOHAVE) 2009 campaign took place on 11-27 October 2009 at the JPL Table Mountain Facility in California (TMF). The main objectives of the campaign were to (1) validate the water vapor measurements of several instruments, including, three Raman lidars, two microwave radiometers, two Fourier-Transform spectrometers, and two GPS receivers (column water), (2) cover water vapor measurements from the ground to the mesopause without gaps, and (3) study upper tropospheric humidity variability at timescales varying from a few minutes to several days. A total of 58 radiosondes and 20 Frost-Point hygrometer sondes were launched. Two types of radiosondes were used during the campaign. Non negligible differences in the readings between the two radiosonde types used (Vaisala RS92 and InterMet iMet-1) made a small, but measurable impact on the derivation of water vapor mixing ratio by the Frost-Point hygrometers. As observed in previous campaigns, the RS92 humidity measurements remained within 5% of the Frost-point in the lower and mid-troposphere, but were too dry in the upper troposphere. Over 270 h of water vapor measurements from three Raman lidars (JPL and GSFC) were compared to RS92, CFH, and NOAA-FPH. The JPL lidar profiles reached 20 km when integrated all night, and 15 km when integrated for 1 h. Excellent agreement between this lidar and the frost-point hygrometers was found throughout the measurement range, with only a 3% (0.3 ppmv) mean wet bias for the lidar in the upper troposphere and lower stratosphere (UTLS). The other two lidars provided satisfactory results in the lower and mid-troposphere (2-5% wet bias over the range 3-10 km), but suffered from contamination by fluorescence (wet bias ranging from 5 to 50% between 10 km and 15 km), preventing their use as an independent measurement in the UTLS. The comparison between all available stratospheric sounders allowed to identify only the

  5. Accelerating cross-validation with total variation and its application to super-resolution imaging

    NASA Astrophysics Data System (ADS)

    Obuchi, Tomoyuki; Ikeda, Shiro; Akiyama, Kazunori; Kabashima, Yoshiyuki

    2017-12-01

    We develop an approximation formula for the cross-validation error (CVE) of a sparse linear regression penalized by ℓ_1-norm and total variation terms, which is based on a perturbative expansion utilizing the largeness of both the data dimensionality and the model. The developed formula allows us to reduce the necessary computational cost of the CVE evaluation significantly. The practicality of the formula is tested through application to simulated black-hole image reconstruction on the event-horizon scale with super resolution. The results demonstrate that our approximation reproduces the CVE values obtained via literally conducted cross-validation with reasonably good precision.

  6. [Reliability and validity of depression scales of Chinese version: a systematic review].

    PubMed

    Sun, X Y; Li, Y X; Yu, C Q; Li, L M

    2017-01-10

    Objective: Through systematically reviewing the reliability and validity of depression scales of Chinese version in adults in China to evaluate the psychometric properties of depression scales for different groups. Methods: Eligible studies published before 6 May 2016 were retrieved from the following database: CNKI, Wanfang, PubMed and Embase. The HSROC model of the diagnostic test accuracy (DTA) for Meta-analysis was used to calculate the pooled sensitivity and specificity of the PHQ-9. Results: A total of 44 papers evaluating the performance of depression scales were included. Results showed that the reliability and validity of the common depression scales were eligible, including the Beck depression inventory (BDI), the Hamilton depression scale (HAMD), the center epidemiological studies depression scale (CES-D), the patient health questionnaire (PHQ) and the Geriatric depression scale (GDS). The Cronbach' s coefficient of most tools were larger than 0.8, while the test-retest reliability and split-half reliability were larger than 0.7, indicating good internal consistency and stability. The criterion validity, convergent validity, discrimination validity and screening validity were acceptable though different cut-off points were recommended by different studies. The pooled sensitivity of the 11 studies evaluating PHQ-9 was 0.88 (95 %CI : 0.85-0.91) while the pooled specificity was 0.89 (95 %CI : 0.82-0.94), which demonstrated the applicability of PHQ-9 in screening depression. Conclusion: The reliability and validity of different depression scales of Chinese version are acceptable. The characteristics of different tools and study population should be taken into consideration when choosing a specific scale.

  7. Human factors engineering and design validation for the redesigned follitropin alfa pen injection device.

    PubMed

    Mahony, Mary C; Patterson, Patricia; Hayward, Brooke; North, Robert; Green, Dawne

    2015-05-01

    To demonstrate, using human factors engineering (HFE), that a redesigned, pre-filled, ready-to-use, pre-asembled follitropin alfa pen can be used to administer prescribed follitropin alfa doses safely and accurately. A failure modes and effects analysis identified hazards and harms potentially caused by use errors; risk-control measures were implemented to ensure acceptable device use risk management. Participants were women with infertility, their significant others, and fertility nurse (FN) professionals. Preliminary testing included 'Instructions for Use' (IFU) and pre-validation studies. Validation studies used simulated injections in a representative use environment; participants received prior training on pen use. User performance in preliminary testing led to IFU revisions and a change to outer needle cap design to mitigate needle stick potential. In the first validation study (49 users, 343 simulated injections), in the FN group, one observed critical use error resulted in a device design modification and another in an IFU change. A second validation study tested the mitigation strategies; previously reported use errors were not repeated. Through an iterative process involving a series of studies, modifications were made to the pen design and IFU. Simulated-use testing demonstrated that the redesigned pen can be used to administer follitropin alfa effectively and safely.

  8. A Serious Game for Clinical Assessment of Cognitive Status: Validation Study

    PubMed Central

    Chignell, Mark; Tierney, Mary C.; Lee, Jacques

    2016-01-01

    Background We propose the use of serious games to screen for abnormal cognitive status in situations where it may be too costly or impractical to use standard cognitive assessments (eg, emergency departments). If validated, serious games in health care could enable broader availability of efficient and engaging cognitive screening. Objective The objective of this work is to demonstrate the feasibility of a game-based cognitive assessment delivered on tablet technology to a clinical sample and to conduct preliminary validation against standard mental status tools commonly used in elderly populations. Methods We carried out a feasibility study in a hospital emergency department to evaluate the use of a serious game by elderly adults (N=146; age: mean 80.59, SD 6.00, range 70-94 years). We correlated game performance against a number of standard assessments, including the Mini-Mental State Examination (MMSE), Montreal Cognitive Assessment (MoCA), and the Confusion Assessment Method (CAM). Results After a series of modifications, the game could be used by a wide range of elderly patients in the emergency department demonstrating its feasibility for use with these users. Of 146 patients, 141 (96.6%) consented to participate and played our serious game. Refusals to play the game were typically due to concerns of family members rather than unwillingness of the patient to play the game. Performance on the serious game correlated significantly with the MoCA (r=–.339, P <.001) and MMSE (r=–.558, P <.001), and correlated (point-biserial correlation) with the CAM (r=.565, P <.001) and with other cognitive assessments. Conclusions This research demonstrates the feasibility of using serious games in a clinical setting. Further research is required to demonstrate the validity and reliability of game-based assessments for clinical decision making. PMID:27234145

  9. A methodology for collecting valid software engineering data

    NASA Technical Reports Server (NTRS)

    Basili, Victor R.; Weiss, David M.

    1983-01-01

    An effective data collection method for evaluating software development methodologies and for studying the software development process is described. The method uses goal-directed data collection to evaluate methodologies with respect to the claims made for them. Such claims are used as a basis for defining the goals of the data collection, establishing a list of questions of interest to be answered by data analysis, defining a set of data categorization schemes, and designing a data collection form. The data to be collected are based on the changes made to the software during development, and are obtained when the changes are made. To insure accuracy of the data, validation is performed concurrently with software development and data collection. Validation is based on interviews with those people supplying the data. Results from using the methodology show that data validation is a necessary part of change data collection. Without it, as much as 50% of the data may be erroneous. Feasibility of the data collection methodology was demonstrated by applying it to five different projects in two different environments. The application showed that the methodology was both feasible and useful.

  10. The City of Hope-Quality of Life-Ostomy Questionnaire: Persian Translation and Validation

    PubMed Central

    Anaraki, F; Vafaie, M; Behboo, R; Esmaeilpour, S; Maghsoodi, N; Safaee, A; Grant, M

    2014-01-01

    Background: Since there is no disease-specific instrument for measuring quality-of-life (QOL) in Ostomy patients in Persian language. Aim: This study was designed to translate and evaluate the validity and reliability of City of Hope-quality of life-Ostomy questionnaire (COH-QOL-Ostomy questionnaire). Subjects and Methods: This study was designed as cross-sectional study. Reliability of the subscales and the summary scores were demonstrated by intra-class correlation coefficients. Pearson's correlations of an item with its own scale and other scales were calculated to evaluated convergent and discriminant validity. Clinical validity was also evaluated by known-group comparisons. Results: Cronbach's alpha coefficient for all subscales was about 0.70 or higher. Results of interscale correlation were satisfactory and each subscale only measured a single and specified trait. All subscales met the standards of convergent and discriminant validity. Known group comparison analysis showed significant differences in social and spiritual well-being. Conclusion: The findings confirmed the reliability and validity of Persian version of COH-QOL-Ostomy questionnaire. The instrument was also well received by the Iranian patients. It can be considered as a valuable instrument to assess the different aspects of health related quality-of-life in Ostomy patients and used in clinical research in the future. PMID:25221719

  11. The validity and reliability of tinnitus handicap inventory Thai version.

    PubMed

    Limviriyakul, Siriporn; Supavanich, Walop

    2012-11-01

    Demonstrate the reliability and validity of the Tinnitus Handicap Inventory Thai Version (THI-T), a self-report measure of tinnitus. A cross-sectional psychometric validation study was used to determine internal consistency reliability and validity of the Tinnitus Handicap Inventory Thai Version at the Otoneurology clinic at Tertiary care center The cross-cultural adaptation of the Tinnitus Handicapped Inventory English version (Newman et al, 1996) was translated into Thai version following the steps indicated by Guillemin et al. The reliability was constructed by using Cronbach's coefficient alpha. The validity was analyzed by the correlation between Tinnitus Handicap Inventory Thai version and the 36-items short form health survey and visual analog scale using Spearman and Pearson test. The result showed good internal consistency reliabilities of total, functional, emotional, and catastrophic scale (a = 0.902, 0.804, 0.831 and 0.661, respectively) of Tinnitus Handicap Inventory Thai Version. Spearman correlation showed the significant correlation of Tinnitus Handicap Inventory to 36-items short form health survey and visual analog scale. Tinnitus Handicap Inventory Thai Version will be a vigorous tool in evaluating tinnitus patients as well as monitoring the progress of their symptoms.

  12. Replication and validation of higher order models demonstrated that a summary score for the EORTC QLQ-C30 is robust.

    PubMed

    Giesinger, Johannes M; Kieffer, Jacobien M; Fayers, Peter M; Groenvold, Mogens; Petersen, Morten Aa; Scott, Neil W; Sprangers, Mirjam A G; Velikova, Galina; Aaronson, Neil K

    2016-01-01

    To further evaluate the higher order measurement structure of the European Organisation for Research and Treatment of Cancer (EORTC) Quality of Life Questionnaire Core 30 (QLQ-C30), with the aim of generating a summary score. Using pretreatment QLQ-C30 data (N = 3,282), we conducted confirmatory factor analyses to test seven previously evaluated higher order models. We compared the summary score(s) derived from the best performing higher order model with the original QLQ-C30 scale scores, using tumor stage, performance status, and change over time (N = 244) as grouping variables. Although all models showed acceptable fit, we continued in the interest of parsimony with known-groups validity and responsiveness analyses using a summary score derived from the single higher order factor model. The validity and responsiveness of this QLQ-C30 summary score was equal to, and in many cases superior to the original, underlying QLQ-C30 scale scores. Our results provide empirical support for a measurement model for the QLQ-C30 yielding a single summary score. The availability of this summary score can avoid problems with potential type I errors that arise because of multiple testing when making comparisons based on the 15 outcomes generated by this questionnaire and may reduce sample size requirements for health-related quality of life studies using the QLQ-C30 questionnaire when an overall summary score is a relevant primary outcome. Copyright © 2016 The Authors. Published by Elsevier Inc. All rights reserved.

  13. The teamwork in assertive community treatment (TACT) scale: development and validation.

    PubMed

    Wholey, Douglas R; Zhu, Xi; Knoke, David; Shah, Pri; Zellmer-Bruhn, Mary; Witheridge, Thomas F

    2012-11-01

    Team design is meticulously specified for assertive community treatment (ACT) teams, yet performance can vary across ACT teams, even those with high fidelity. By developing and validating the Teamwork in Assertive Community Treatment (TACT) scale, investigators examined the role of team processes in ACT performance. The TACT scale measuring ACT teamwork was developed from a conceptual model grounded in organizational research and adapted for the ACT and mental health context. TACT subscales were constructed after exploratory and confirmatory factor analyses. The reliability, discriminant validity, predictive validity, temporal stability, internal consistency, and within-team agreement were established with surveys from approximately 300 members of 26 Minnesota ACT teams who completed the questionnaire three times, at six-month intervals. Nine TACT subscales emerged from the analyses: exploration, exploitation of new and existing knowledge, psychological safety, goal agreement, conflict, constructive controversy, information accessibility, encounter preparedness, and consumer-centered care. These nine subscales demonstrated fit and temporal stability (confirmatory factor analysis), high internal consistency (Cronbach's alpha), and within-team agreement and between-team differences (rwg and intraclass correlations). Correlational analyses of the subscales revealed that they measure related yet distinctive aspects of ACT team processes, and regression analyses demonstrated predictive validity (encounter preparedness is related to staff outcomes). The TACT scale demonstrated high reliability and validity and can be included in research and evaluation of teamwork in ACT and mental health teams.

  14. Construct validity of the PROMIS® sexual function and satisfaction measures in patients with cancer

    PubMed Central

    2013-01-01

    Background With data from a diverse sample of patients either in treatment for cancer or post-treatment for cancer, we examine inter-domain and cross-domain correlations among the core domains of the Patient-Reported Outcomes Measurement Information System Sexual Function and Satisfaction measures (PROMIS® SexFS) and the corresponding domains from conceptually-similar measures of sexual function, the International Index of Erectile Function and the Female Sexual Function Index. Findings Men (N=389) and women (N=430) were recruited from a tumor registry, oncology clinics, and an internet panel. The PROMIS SexFS, International Index of Erectile Function, and Female Sexual Function Index were used to collect participants’ self-reported sexual function. The domains shared among the measures include desire/interest in sexual activity, lubrication and vaginal discomfort/pain (women), erectile function (men), orgasm, and satisfaction. We examined correlations among different domains within the same instrument (discriminant validity) and correlations among similar domains measured by different instruments (convergent validity). Correlations demonstrating discriminant validity ranged from 0.38 to 0.73 for men and 0.48 to 0.74 for women, while correlations demonstrating convergent validity ranged from 0.62 to 0.83 for men and 0.71 to 0.92 for women. As expected, correlations demonstrating convergent validity were higher than correlations demonstrating discriminant validity, with one exception (orgasm for men). Conclusions Construct validity was supported by convergent and discriminant validity in a diverse sample of patients with cancer. For patients with cancer who may or may not have sexual dysfunction, the PROMIS SexFS measures provide a comprehensive assessment of key domains of sexual function and satisfaction. PMID:23497200

  15. Development and validation of a fatigue assessment scale for U.S. construction workers.

    PubMed

    Zhang, Mingzong; Sparer, Emily H; Murphy, Lauren A; Dennerlein, Jack T; Fang, Dongping; Katz, Jeffrey N; Caban-Martinez, Alberto J

    2015-02-01

    To develop a fatigue assessment scale and test its reliability and validity for commercial construction workers. Using a two-phased approach, we first identified items (first phase) for the development of a Fatigue Assessment Scale for Construction Workers (FASCW) through review of existing scales in the scientific literature, key informant interviews (n = 11) and focus groups (three groups with six workers each) with construction workers. The second phase included assessment for the reliability, validity, and sensitivity of the new scale using a repeated-measures study design with a convenience sample of construction workers (n = 144). Phase one resulted in a 16-item preliminary scale that after factor analysis yielded a final 10-item scale with two sub-scales ("Lethargy" and "Bodily Ailment"). During phase two, the FASCW and its subscales demonstrated satisfactory internal consistency (alpha coefficients were FASCW [0.91], Lethargy [0.86] and Bodily Ailment [0.84]) and acceptable test-retest reliability (Pearson Correlations Coefficients: 0.59-0.68; Intraclass Correlation Coefficients: 0.74-0.80). Correlation analysis substantiated concurrent and convergent validity. A discriminant analysis demonstrated that the FASCW differentiated between groups with arthritis status and different work hours. The 10-item FASCW with good reliability and validity is an effective tool for assessing the severity of fatigue among construction workers. © 2015 Wiley Periodicals, Inc.

  16. Validation of an automated mite counter for Dermanyssus gallinae in experimental laying hen cages.

    PubMed

    Mul, Monique F; van Riel, Johan W; Meerburg, Bastiaan G; Dicke, Marcel; George, David R; Groot Koerkamp, Peter W G

    2015-08-01

    For integrated pest management (IPM) programs to be maximally effective, monitoring of the growth and decline of the pest populations is essential. Here, we present the validation results of a new automated monitoring device for the poultry red mite (Dermanyssus gallinae), a serious pest in laying hen facilities world-wide. This monitoring device (called an "automated mite counter") was validated in experimental laying hen cages with live birds and a growing population of D. gallinae. This validation study resulted in 17 data points of 'number of mites counted' by the automated mite counter and the 'number of mites present' in the experimental laying hen cages. The study demonstrated that the automated mite counter was able to track the D. gallinae population effectively. A wider evaluation showed that this automated mite counter can become a useful tool in IPM of D. gallinae in laying hen facilities.

  17. Tested Demonstrations.

    ERIC Educational Resources Information Center

    Gilbert, George L., Ed.

    1988-01-01

    Describes two demonstrations for use in college chemistry classes. Includes "Spectroscopy in Large Lecture Halls" and "The Endothermic Dissolution of Ammonium Nitrate." Gives materials lists and procedures as well as a discussion of the results. (CW)

  18. Internal validation of two new retrotransposons-based kits (InnoQuant® HY and InnoTyper® 21) at a forensic lab.

    PubMed

    Martins, Cátia; Ferreira, Paulo Miguel; Carvalho, Raquel; Costa, Sandra Cristina; Farinha, Carlos; Azevedo, Luísa; Amorim, António; Oliveira, Manuela

    2018-02-01

    Obtaining a genetic profile from pieces of evidence collected at a crime scene is the primary objective of forensic laboratories. New procedures, methods, kits, software or equipment must be carefully evaluated and validated before its implementation. The constant development of new methodologies for DNA testing leads to a steady process of validation, which consists of demonstrating that the technology is robust, reproducible, and reliable throughout a defined range of conditions. The present work aims to internally validate two new retrotransposon-based kits (InnoQuant ® HY and InnoTyper ® 21), under the working conditions of the Laboratório de Polícia Científica da Polícia Judiciária (LPC-PJ). For the internal validation of InnoQuant ® HY and InnoTyper ® 21 sensitivity, repeatability, reproducibility, and mixture tests and a concordance study between these new kits and those currently in use at LPC-PJ (Quantifiler ® Duo and GlobalFiler™) were performed. The results obtained for sensitivity, repeatability, and reproducibility tests demonstrated that both InnoQuant ® HY and InnoTyper ® 21 are robust, reproducible, and reliable. The results of the concordance studies demonstrate that InnoQuant ® HY produced quantification results in nearly 29% more than Quantifiler ® Duo (indicating that this new kit is more effective in challenging samples), while the differences observed between InnoTyper ® 21 and GlobalFiler™ are not significant. Therefore, the utility of InnoTyper ® 21 has been proven, especially by the successful amplification of a greater number of complete genetic profiles (27 vs. 21). The results herein presented allowed the internal validation of both InnoQuant ® HY and InnoTyper ® 21, and their implementation in the LPC-PJ laboratory routine for the treatment of challenging samples. Copyright © 2017 Elsevier B.V. All rights reserved.

  19. Aging aircraft NDI Development and Demonstration Center (AANC): An overview. [nondestructive inspection

    NASA Technical Reports Server (NTRS)

    Walter, Patrick L.

    1992-01-01

    A major center with emphasis on validation of nondestructive inspection (NDI) techniques for aging aircraft, the Aging Aircraft NDI Development and Demonstration Center (AANC), has been funded by the FAA at Sandia National Laboratories. The Center has been assigned specific tasks in developing techniques for the nondestructive inspection of static engine parts, assessing inspection reliability (POD experiments), developing testbeds for NDI validation, maintaining a FAA library of characterized aircraft structural test specimens, and leasing a hangar to house a high flight cycle transport aircraft for use as a full scale test bed.

  20. Validating a Geographical Image Retrieval System.

    ERIC Educational Resources Information Center

    Zhu, Bin; Chen, Hsinchun

    2000-01-01

    Summarizes a prototype geographical image retrieval system that demonstrates how to integrate image processing and information analysis techniques to support large-scale content-based image retrieval. Describes an experiment to validate the performance of this image retrieval system against that of human subjects by examining similarity analysis…

  1. Validation of WIND for a Series of Inlet Flows

    NASA Technical Reports Server (NTRS)

    Slater, John W.; Abbott, John M.; Cavicchi, Richard H.

    2002-01-01

    Validation assessments compare WIND CFD simulations to experimental data for a series of inlet flows ranging in Mach number from low subsonic to hypersonic. The validation procedures follow the guidelines of the AIAA. The WIND code performs well in matching the available experimental data. The assessments demonstrate the use of WIND and provide confidence in its use for the analysis of aircraft inlets.

  2. Validation Results for LEWICE 2.0

    NASA Technical Reports Server (NTRS)

    Wright, William B.; Rutkowski, Adam

    1999-01-01

    A research project is underway at NASA Lewis to produce a computer code which can accurately predict ice growth under any meteorological conditions for any aircraft surface. This report will present results from version 2.0 of this code, which is called LEWICE. This version differs from previous releases due to its robustness and its ability to reproduce results accurately for different spacing and time step criteria across computing platform. It also differs in the extensive amount of effort undertaken to compare the results in a quantified manner against the database of ice shapes which have been generated in the NASA Lewis Icing Research Tunnel (IRT). The results of the shape comparisons are analyzed to determine the range of meteorological conditions under which LEWICE 2.0 is within the experimental repeatability. This comparison shows that the average variation of LEWICE 2.0 from the experimental data is 7.2% while the overall variability of the experimental data is 2.5%.

  3. Towards a conceptual framework demonstrating the effectiveness of audiovisual patient descriptions (patient video cases): a review of the current literature

    PubMed Central

    2012-01-01

    Background Technological advances have enabled the widespread use of video cases via web-streaming and online download as an educational medium. The use of real subjects to demonstrate acute pathology should aid the education of health care professionals. However, the methodology by which this effect may be tested is not clear. Methods We undertook a literature review of major databases, found relevant articles relevant to using patient video cases as educational interventions, extracted the methodologies used and assessed these methods for internal and construct validity. Results A review of 2532 abstracts revealed 23 studies meeting the inclusion criteria and a final review of 18 of relevance. Medical students were the most commonly studied group (10 articles) with a spread of learner satisfaction, knowledge and behaviour tested. Only two of the studies fulfilled defined criteria on achieving internal and construct validity. The heterogeneity of articles meant it was not possible to perform any meta-analysis. Conclusions Previous studies have not well classified which facet of training or educational outcome the study is aiming to explore and had poor internal and construct validity. Future research should aim to validate a particular outcome measure, preferably by reproducing previous work rather than adopting new methods. In particular cognitive processing enhancement, demonstrated in a number of the medical student studies, should be tested at a postgraduate level. PMID:23256787

  4. Reliability and validity of the Lithuanian Tinnitus Handicap Inventory.

    PubMed

    Ulozienė, Ingrida; Balnytė, Renata; Alzbutienė, Giedrė; Arechvo, Irina; Vaitkus, Antanas; Šileikaitė, Milda; Šaferis, Viktoras; Ulozas, Virgilijus

    2016-01-01

    The aim of this study was to determine the reliability and validity of the Lithuanian version of the Tinnitus Handicap Inventory (THI), a self-report measure of perceived tinnitus handicap. A cross-sectional psychometric validation study was performed in the University Hospital. A total of 248 subjects reporting chronic tinnitus as their primary complaint or secondary to hearing loss were encluded in the study and filled in the Lithuanian version of THI. For assessment of construct validity a subgroup of 55 participants completed the Lithuanian version of the Hospital Anxiety and Depression Scale as a measure of self-perceived levels of anxiety and depression. Test-retest and internal consistency reliability as well as construct validity were calculated. The Lithuanian version of the THI and its subscales showed a robust internal consistency reliability (Cronbach's alpha=0.93) comparable to the original version. Statistically significant correlations were observed between the Lithuanian translation of the THI and the measures of self-perceived levels of anxiety and depression using HADS. Confirmatory factor analysis demonstrated that the three subscales of the THI Lithuanian version corresponded to three different factors, which strongly correlated between themselves. The results suggest that the Lithuanian version of THI maintains its original validity and may serve as reliable and valid measure of general tinnitus related distress that can be used in a clinical setting to quantify the impact of tinnitus on daily living. Copyright © 2016 The Lithuanian University of Health Sciences. Production and hosting by Elsevier Urban & Partner Sp. z o.o. All rights reserved.

  5. ATHENA X-IFU 300 K-50 mK cryochain demonstrator cryostat

    NASA Astrophysics Data System (ADS)

    Prouvé, T.; Duval, J. M.; Charles, I.; Yamasaki, N. Y.; Mitsuda, K.; Nakagawa, T.; Shinozaki, K.; Tokoku, C.; Yamamoto, R.; Minami, Y.; Le Du, M.; Andre, J.; Daniel, C.; Linder, M.

    2018-01-01

    In the framework of the ESA X-ray mission ATHENA, scheduled for launch in 2028, an ESA Core Technology Program (CTP) was started in 2016 to build a flight like cryostat demonstrator in parallel with the phase A studies of the ATHENA/X-IFU instrument [1,2]. As part of this CTP, called the Detector Cooling System (DCS), design, manufacturing and test of a cryostat including existing space coolers will be done. In addition to the validation of thermal performance, a Focal Plan Assembly (FPA) demonstrator using Transition Edge Sensors (TES) detector technology will be also integrated and its performance characterized versus the environment provided by the cryostat. This is a unique opportunity to validate many crucial issues of the cryogenic part of such a sensitive instrument. A dedicated activity within this CTP-DCS is the demonstration of the 300 K-50 mK cooling chain in a Ground System Equipment (GSE) cryostat. The studies are focused on the operation of the space coolers, which is made possible by the use of a ground cooler for cooling cryogenic shields and mechanical supports. Thanks to the modularity of the cryostat, several cooling chains could be tested. In the base line configuration described here, the low temperature stage is the CEA hybrid sorption/ADR 50 mK cooler with thermal interfaces at 4 K and 2 K. 4 K cooling is accomplished by a 4 K Joule-Thomson (JT) cryocooler and its Stirling precooler provided by JAXA. Regarding the 2 K stage, at first a 2 K JT from JAXA will be used. Alternatively, a 2 K JT cooler from RAL could replace the JAXA 2 K JT. In both cases new prototype(s) of a 2 K JT will be implemented, precooled by the EM 15 K pule tube cooler from Air Liquide. This test program is also the opportunity to validate the operation of the cryochain with respect to various requirements, such as time constant and temperature stabilities. This would bring us valuable inputs to integrate the cryochain in DCS cryostat or for the X-IFU phase A studies

  6. Validation of the updated ArthroS simulator: face and construct validity of a passive haptic virtual reality simulator with novel performance metrics.

    PubMed

    Garfjeld Roberts, Patrick; Guyver, Paul; Baldwin, Mathew; Akhtar, Kash; Alvand, Abtin; Price, Andrew J; Rees, Jonathan L

    2017-02-01

    To assess the construct and face validity of ArthroS, a passive haptic VR simulator. A secondary aim was to evaluate the novel performance metrics produced by this simulator. Two groups of 30 participants, each divided into novice, intermediate or expert based on arthroscopic experience, completed three separate tasks on either the knee or shoulder module of the simulator. Performance was recorded using 12 automatically generated performance metrics and video footage of the arthroscopic procedures. The videos were blindly assessed using a validated global rating scale (GRS). Participants completed a survey about the simulator's realism and training utility. This new simulator demonstrated construct validity of its tasks when evaluated against a GRS (p ≤ 0.003 in all cases). Regarding it's automatically generated performance metrics, established outputs such as time taken (p ≤ 0.001) and instrument path length (p ≤ 0.007) also demonstrated good construct validity. However, two-thirds of the proposed 'novel metrics' the simulator reports could not distinguish participants based on arthroscopic experience. Face validity assessment rated the simulator as a realistic and useful tool for trainees, but the passive haptic feedback (a key feature of this simulator) is rated as less realistic. The ArthroS simulator has good task construct validity based on established objective outputs, but some of the novel performance metrics could not distinguish between surgical experience. The passive haptic feedback of the simulator also needs improvement. If simulators could offer automated and validated performance feedback, this would facilitate improvements in the delivery of training by allowing trainees to practise and self-assess.

  7. Achievement-Relevant Personality: Relations with the Big Five and Validation of an Efficient Instrument

    PubMed Central

    Briley, Daniel A.; Domiteaux, Matthew; Tucker-Drob, Elliot M.

    2014-01-01

    Many achievement-relevant personality measures (APMs) have been developed, but the interrelations among APMs or associations with the broader personality landscape are not well-known. In Study 1, 214 participants were measured on 36 APMs and a measure of the Big Five. Factor analytic results supported the convergent and discriminant validity of five latent dimensions: performance, mastery, self-doubt, effort, and intellectual investment. Conscientiousness, neuroticism, and openness to experience had the most consistent associations with APMs. We constructed a more efficient scale– the Multidimensional Achievement-Relevant Personality Scale (MAPS). In Study 2, we replicated the factor structure and external correlates of the MAPS in a sample of 359 individuals. Finally, we validated the MAPS with four indicators of academic performance and demonstrated incremental validity. PMID:24839374

  8. Out-of-plane buckling of pantographic fabrics in displacement-controlled shear tests: experimental results and model validation

    NASA Astrophysics Data System (ADS)

    Barchiesi, Emilio; Ganzosch, Gregor; Liebold, Christian; Placidi, Luca; Grygoruk, Roman; Müller, Wolfgang H.

    2018-01-01

    Due to the latest advancements in 3D printing technology and rapid prototyping techniques, the production of materials with complex geometries has become more affordable than ever. Pantographic structures, because of their attractive features, both in dynamics and statics and both in elastic and inelastic deformation regimes, deserve to be thoroughly investigated with experimental and theoretical tools. Herein, experimental results relative to displacement-controlled large deformation shear loading tests of pantographic structures are reported. In particular, five differently sized samples are analyzed up to first rupture. Results show that the deformation behavior is strongly nonlinear, and the structures are capable of undergoing large elastic deformations without reaching complete failure. Finally, a cutting edge model is validated by means of these experimental results.

  9. Factor Structure and Validation of a Set of Readiness Measures.

    ERIC Educational Resources Information Center

    Kaufman, Maurice; Lynch, Mervin

    A study was undertaken to identify the factor structure of a battery of readiness measures and to demonstrate the concurrent and predictive validity of one instrument in that battery--the Pre-Reading Screening Procedures (PSP). Concurrent validity was determined by examining the correlation of the PSP with the Metropolitan Readiness Test (MRT),…

  10. Monitoring sedation status over time in ICU patients: reliability and validity of the Richmond Agitation-Sedation Scale (RASS).

    PubMed

    Ely, E Wesley; Truman, Brenda; Shintani, Ayumi; Thomason, Jason W W; Wheeler, Arthur P; Gordon, Sharon; Francis, Joseph; Speroff, Theodore; Gautam, Shiva; Margolin, Richard; Sessler, Curtis N; Dittus, Robert S; Bernard, Gordon R

    2003-06-11

    Goal-directed delivery of sedative and analgesic medications is recommended as standard care in intensive care units (ICUs) because of the impact these medications have on ventilator weaning and ICU length of stay, but few of the available sedation scales have been appropriately tested for reliability and validity. To test the reliability and validity of the Richmond Agitation-Sedation Scale (RASS). Prospective cohort study. Adult medical and coronary ICUs of a university-based medical center. Thirty-eight medical ICU patients enrolled for reliability testing (46% receiving mechanical ventilation) from July 21, 1999, to September 7, 1999, and an independent cohort of 275 patients receiving mechanical ventilation were enrolled for validity testing from February 1, 2000, to May 3, 2001. Interrater reliability of the RASS, Glasgow Coma Scale (GCS), and Ramsay Scale (RS); validity of the RASS correlated with reference standard ratings, assessments of content of consciousness, GCS scores, doses of sedatives and analgesics, and bispectral electroencephalography. In 290-paired observations by nurses, results of both the RASS and RS demonstrated excellent interrater reliability (weighted kappa, 0.91 and 0.94, respectively), which were both superior to the GCS (weighted kappa, 0.64; P<.001 for both comparisons). Criterion validity was tested in 411-paired observations in the first 96 patients of the validation cohort, in whom the RASS showed significant differences between levels of consciousness (P<.001 for all) and correctly identified fluctuations within patients over time (P<.001). In addition, 5 methods were used to test the construct validity of the RASS, including correlation with an attention screening examination (r = 0.78, P<.001), GCS scores (r = 0.91, P<.001), quantity of different psychoactive medication dosages 8 hours prior to assessment (eg, lorazepam: r = - 0.31, P<.001), successful extubation (P =.07), and bispectral electroencephalography (r = 0.63, P

  11. Translation, Cross-cultural Adaptation and Psychometric Validation of the Korean-Language Cardiac Rehabilitation Barriers Scale (CRBS-K)

    PubMed Central

    2017-01-01

    Objective To perform a translation and cross-cultural adaptation of the Cardiac Rehabilitation Barriers Scale (CRBS) for use in Korea, followed by psychometric validation. The CRBS was developed to assess patients' perception of the degree to which patient, provider and health system-level barriers affect their cardiac rehabilitation (CR) participation. Methods The CRBS consists of 21 items (barriers to adherence) rated on a 5-point Likert scale. The first phase was to translate and cross-culturally adapt the CRBS to the Korean language. After back-translation, both versions were reviewed by a committee. The face validity was assessed in a sample of Korean patients (n=53) with history of acute myocardial infarction that did not participate in CR through semi-structured interviews. The second phase was to assess the construct and criterion validity of the Korean translation as well as internal reliability, through administration of the translated version in 104 patients, principle component analysis with varimax rotation and cross-referencing against CR use, respectively. Results The length, readability, and clarity of the questionnaire were rated well, demonstrating face validity. Analysis revealed a six-factor solution, demonstrating construct validity. Cronbach's alpha was greater than 0.65. Barriers rated highest included not knowing about CR and not being contacted by a program. The mean CRBS score was significantly higher among non-attendees (2.71±0.26) than CR attendees (2.51±0.18) (p<0.01). Conclusion The Korean version of CRBS has demonstrated face, content and criterion validity, suggesting it may be useful for assessing barriers to CR utilization in Korea. PMID:29201826

  12. Task-oriented evaluation of electronic medical records systems: development and validation of a questionnaire for physicians

    PubMed Central

    2004-01-01

    Background Evaluation is a challenging but necessary part of the development cycle of clinical information systems like the electronic medical records (EMR) system. It is believed that such evaluations should include multiple perspectives, be comparative and employ both qualitative and quantitative methods. Self-administered questionnaires are frequently used as a quantitative evaluation method in medical informatics, but very few validated questionnaires address clinical use of EMR systems. Methods We have developed a task-oriented questionnaire for evaluating EMR systems from the clinician's perspective. The key feature of the questionnaire is a list of 24 general clinical tasks. It is applicable to physicians of most specialties and covers essential parts of their information-oriented work. The task list appears in two separate sections, about EMR use and task performance using the EMR, respectively. By combining these sections, the evaluator may estimate the potential impact of the EMR system on health care delivery. The results may also be compared across time, site or vendor. This paper describes the development, performance and validation of the questionnaire. Its performance is shown in two demonstration studies (n = 219 and 80). Its content is validated in an interview study (n = 10), and its reliability is investigated in a test-retest study (n = 37) and a scaling study (n = 31). Results In the interviews, the physicians found the general clinical tasks in the questionnaire relevant and comprehensible. The tasks were interpreted concordant to their definitions. However, the physicians found questions about tasks not explicitly or only partially supported by the EMR systems difficult to answer. The two demonstration studies provided unambiguous results and low percentages of missing responses. In addition, criterion validity was demonstrated for a majority of task-oriented questions. Their test-retest reliability was generally high, and the non

  13. Development and Validation of the Elder Learning Barriers Scale Among Older Chinese Adults.

    PubMed

    Wang, Renfeng; De Donder, Liesbeth; De Backer, Free; He, Tao; Van Regenmortel, Sofie; Li, Shihua; Lombaerts, Koen

    2017-12-01

    This study describes the development and validation of the Elder Learning Barriers (ELB) scale, which seeks to identify the obstacles that affect the level of educational participation of older adults. The process of item pool design and scale development is presented, as well as the testing and scale refinement procedure. The data were collected from a sample of 579 older Chinese adults (aged over 55) in the Xi'an region of China. After randomly splitting the sample for cross-validation purposes, the construct validity of the ELB scale was confirmed containing five dimensions: dispositional, informational, physical, situational, and institutional barriers. Furthermore, developmental differences in factor structure have been examined among older age groups. The results indicated that the scale demonstrated good reliability and validity. We conclude in general that the ELB scale appears to be a valuable instrument for examining the learning barriers that older Chinese citizens experience for participating in organized educational activities.

  14. Attitudes Toward Transgender Men and Women: Development and Validation of a New Measure

    PubMed Central

    Billard, Thomas J

    2018-01-01

    A series of three studies were conducted to generate, develop, and validate the Attitudes toward Transgender Men and Women (ATTMW) scale. In Study 1, 120 American adults responded to an open-ended questionnaire probing various dimensions of their perceptions of transgender individuals and identity. Qualitative thematic analysis generated 200 items based on their responses. In Study 2, 238 American adults completed a questionnaire consisting of the generated items. Exploratory factor analysis (EFA) revealed two non-identical 12-item subscales (ATTM and ATTW) of the full 24-item scale. In Study 3, 150 undergraduate students completed a survey containing the ATTMW and a number of validity-testing variables. Confirmatory factor analysis (CFA) verified the single-factor structures of the ATTM and ATTW subscales, and the convergent, discriminant, predictive, and concurrent validities of the ATTMW were also established. Together, our results demonstrate that the ATTMW is a reliable and valid measure of attitudes toward transgender individuals. PMID:29666595

  15. Ovarian and cervical cancer awareness: development of two validated measurement tools

    PubMed Central

    Simon, Alice E; Wardle, Jane; Grimmett, Chloe; Power, Emily; Corker, Elizabeth; Menon, Usha; Matheson, Lauren; Waller, Jo

    2012-01-01

    Background The aim of the study was to develop and validate measures of awareness of symptoms and risk factors for ovarian and cervical cancer (Ovarian and Cervical Cancer Awareness Measures). Methods Potentially relevant items were extracted from the literature and generated by experts. Four validation studies were carried out to establish reliability and validity. Women aged 21–67 years (n=146) and ovarian and cervical cancer experts (n=32) were included in the studies. Internal reliability was assessed psychometrically. Test-retest reliability was assessed over a 1-week interval. To establish construct validity, Cancer Awareness Measure (CAM) scores of cancer experts were compared with equally well-educated comparison groups. Sensitivity to change was tested by randomly assigning participants to read either a leaflet giving information about ovarian/cervical cancer or a leaflet with control information, and then completing the ovarian/cervical CAM. Results Internal reliability (Cronbach's α=0.88 for the ovarian CAM and α=0.84 for the cervical CAM) and test-retest reliability (r=0.84 and r=0.77 for the ovarian and cervical CAMs, respectively) were both high. Validity was demonstrated with cancer experts achieving higher scores than controls [ovarian CAM: t(36)= –5.6, p<0.001; cervical CAM: t(38)= –3.7, p=0.001], and volunteers who were randomised to read a cancer leaflet scored higher than those who received a control leaflet [ovarian CAM: t(49)=7.5, p<0.001; cervical CAM: t(48)= –5.5, p<0.001]. Conclusions This study demonstrates the psychometric properties of the ovarian and cervical CAMs and supports their utility in assessing ovarian and cervical cancer awareness in the general population. PMID:21933805

  16. USFWS demonstration fees

    USGS Publications Warehouse

    Taylor, Jonathan; Vaske, Jerry; Donnelly, Maureen; Shelby, Lori

    2002-01-01

    This study examined National Wildlife Refuge (NWR) visitors' reactions to changes in fees implemented as part of the fee demonstration program. Visitors' evaluations of the fees paid were examined in addition to their beliefs about fees and the fee demonstration program, and the impact of fees paid on their intention to return. All results were analyzed relative to socio-demographic characteristics.

  17. A reliability and validity study of the Palliative Performance Scale

    PubMed Central

    Ho, Francis; Lau, Francis; Downing, Michael G; Lesperance, Mary

    2008-01-01

    Background The Palliative Performance Scale (PPS) was first introduced in1996 as a new tool for measurement of performance status in palliative care. PPS has been used in many countries and has been translated into other languages. Methods This study evaluated the reliability and validity of PPS. A web-based, case scenarios study with a test-retest format was used to determine reliability. Fifty-three participants were recruited and randomly divided into two groups, each evaluating 11 cases at two time points. The validity study was based on the content validation of 15 palliative care experts conducted over telephone interviews, with discussion on five themes: PPS as clinical assessment tool, the usefulness of PPS, PPS scores affecting decision making, the problems in using PPS, and the adequacy of PPS instruction. Results The intraclass correlation coefficients for absolute agreement were 0.959 and 0.964 for Group 1, at Time-1 and Time-2; 0.951 and 0.931 for Group 2, at Time-1 and Time-2 respectively. Results showed that the participants were consistent in their scoring over the two times, with a mean Cohen's kappa of 0.67 for Group 1 and 0.71 for Group 2. In the validity study, all experts agreed that PPS is a valuable clinical assessment tool in palliative care. Many of them have already incorporated PPS as part of their practice standard. Conclusion The results of the reliability study demonstrated that PPS is a reliable tool. The validity study found that most experts did not feel a need to further modify PPS and, only two experts requested that some performance status measures be defined more clearly. Areas of PPS use include prognostication, disease monitoring, care planning, hospital resource allocation, clinical teaching and research. PPS is also a good communication tool between palliative care workers. PMID:18680590

  18. Torso-Tank Validation of High-Resolution Electrogastrography (EGG): Forward Modelling, Methodology and Results.

    PubMed

    Calder, Stefan; O'Grady, Greg; Cheng, Leo K; Du, Peng

    2018-04-27

    Electrogastrography (EGG) is a non-invasive method for measuring gastric electrical activity. Recent simulation studies have attempted to extend the current clinical utility of the EGG, in particular by providing a theoretical framework for distinguishing specific gastric slow wave dysrhythmias. In this paper we implement an experimental setup called a 'torso-tank' with the aim of expanding and experimentally validating these previous simulations. The torso-tank was developed using an adult male torso phantom with 190 electrodes embedded throughout the torso. The gastric slow waves were reproduced using an artificial current source capable of producing 3D electrical fields. Multiple gastric dysrhythmias were reproduced based on high-resolution mapping data from cases of human gastric dysfunction (gastric re-entry, conduction blocks and ectopic pacemakers) in addition to normal test data. Each case was recorded and compared to the previously-presented simulated results. Qualitative and quantitative analyses were performed to define the accuracy showing [Formula: see text] 1.8% difference, [Formula: see text] 0.99 correlation, and [Formula: see text] 0.04 normalised RMS error between experimental and simulated findings. These results reaffirm previous findings and these methods in unison therefore present a promising morphological-based methodology for advancing the understanding and clinical applications of EGG.

  19. Dynamic modeling and validation of a lignocellulosic enzymatic hydrolysis process--a demonstration scale study.

    PubMed

    Prunescu, Remus Mihail; Sin, Gürkan

    2013-12-01

    The enzymatic hydrolysis process is one of the key steps in second generation biofuel production. After being thermally pretreated, the lignocellulosic material is liquefied by enzymes prior to fermentation. The scope of this paper is to evaluate a dynamic model of the hydrolysis process on a demonstration scale reactor. The following novel features are included: the application of the Convection-Diffusion-Reaction equation to a hydrolysis reactor to assess transport and mixing effects; the extension of a competitive kinetic model with enzymatic pH dependency and hemicellulose hydrolysis; a comprehensive pH model; and viscosity estimations during the course of reaction. The model is evaluated against real data extracted from a demonstration scale biorefinery throughout several days of operation. All measurements are within predictions uncertainty and, therefore, the model constitutes a valuable tool to support process optimization, performance monitoring, diagnosis and process control at full-scale studies. Copyright © 2013 Elsevier Ltd. All rights reserved.

  20. Experimental validation of structural optimization methods

    NASA Technical Reports Server (NTRS)

    Adelman, Howard M.

    1992-01-01

    The topic of validating structural optimization methods by use of experimental results is addressed. The need for validating the methods as a way of effecting a greater and an accelerated acceptance of formal optimization methods by practicing engineering designers is described. The range of validation strategies is defined which includes comparison of optimization results with more traditional design approaches, establishing the accuracy of analyses used, and finally experimental validation of the optimization results. Examples of the use of experimental results to validate optimization techniques are described. The examples include experimental validation of the following: optimum design of a trussed beam; combined control-structure design of a cable-supported beam simulating an actively controlled space structure; minimum weight design of a beam with frequency constraints; minimization of the vibration response of helicopter rotor blade; minimum weight design of a turbine blade disk; aeroelastic optimization of an aircraft vertical fin; airfoil shape optimization for drag minimization; optimization of the shape of a hole in a plate for stress minimization; optimization to minimize beam dynamic response; and structural optimization of a low vibration helicopter rotor.