Sample records for values in measurement

  1. Measuring Value in Internal Medicine Residency Training Hospitals Using Publicly Reported Measures.

    PubMed

    Schickedanz, Adam; Gupta, Reshma; Arora, Vineet M; Braddock, Clarence H

    2018-03-01

    Graduate medical education (GME) lacks measures of resident preparation for high-quality, cost-conscious practice. The authors used publicly reported teaching hospital value measures to compare internal medicine residency programs on high-value care training and to validate these measures against program director perceptions of value. Program-level value training scores were constructed using Centers for Medicare & Medicaid Services Value-Based Purchasing (VBP) Program hospital quality and cost-efficiency data. Correlations with Association of Program Directors in Internal Medicine Annual Survey high-value care training measures were examined using logistic regression. For every point increase in program-level VBP score, residency directors were more likely to agree that GME programs have a responsibility to contain health care costs (adjusted odds ratio [aOR] 1.18, P = .04), their faculty model high-value care (aOR 1.07, P = .03), and residents are prepared to make high-value medical decisions (aOR 1.07, P = .09). Publicly reported clinical data offer valid measures of GME value training.

  2. Measuring value sensitivity in medicine.

    PubMed

    Ineichen, Christian; Christen, Markus; Tanner, Carmen

    2017-01-28

    Value sensitivity - the ability to recognize value-related issues when they arise in practice - is an indispensable competence for medical practitioners to enter decision-making processes related to ethical questions. However, the psychological competence of value sensitivity is seldom an explicit subject in the training of medical professionals. In this contribution, we outline the traditional concept of moral sensitivity in medicine and its revised form conceptualized as value sensitivity and we propose an instrument that measures value sensitivity. We developed an instrument for assessing the sensitivity for three value groups (moral-related values, values related to the principles of biomedical ethics, strategy-related values) in a four step procedure: 1) value identification (n = 317); 2) value representation (n = 317); 3) vignette construction and quality evaluation (n = 37); and 4) instrument validation by comparing nursing professionals with hospital managers (n = 48). We find that nursing professionals recognize and ascribe importance to principle-related issues more than professionals from hospital management. The latter are more likely to recognize and ascribe importance to strategy-related issues. These hypothesis-driven results demonstrate the discriminatory power of our newly developed instrument, which makes it useful not only for health care professionals in practice but for students and people working in the clinical context as well.

  3. Developing a Measure of Value in Health Care.

    PubMed

    Ken Lee, K H; Matthew Austin, J; Pronovost, Peter J

    2016-06-01

    There is broad support to pay for value, rather than volume, for health care in the United States. Despite the support, practical approaches for measuring value remain elusive. Value is commonly defined as quality divided by costs, where quality reflects patient outcomes and costs are the total costs for providing care, whether these be costs related to an episode, a diagnosis, or per capita. Academicians have proposed a conceptual approach to measure value, in which we measure outcomes important to patients and costs using time-driven activity-based costing. This approach is conceptually sound, but has significant practical challenges. In our commentary, we describe how health care can use existing quality measures and cost accounting data to measure value. Although not perfect, we believe this approach is practical, valid, and scalable and can establish the foundation for future work in this area. Copyright © 2016 International Society for Pharmacoeconomics and Outcomes Research (ISPOR). Published by Elsevier Inc. All rights reserved.

  4. Measuring Values in Environmental Research: A Test of an Environmental Portrait Value Questionnaire

    PubMed Central

    Bouman, Thijs; Steg, Linda; Kiers, Henk A. L.

    2018-01-01

    Four human values are considered to underlie individuals’ environmental beliefs and behaviors: biospheric (i.e., concern for environment), altruistic (i.e., concern for others), egoistic (i.e., concern for personal resources) and hedonic values (i.e., concern for pleasure and comfort). These values are typically measured with an adapted and shortened version of the Schwartz Value Survey (SVS), to which we refer as the Environmental-SVS (E-SVS). Despite being well-validated, recent research has indicated some concerns about the SVS methodology (e.g., comprehensibility, self-presentation biases) and suggested an alternative method of measuring human values: The Portrait Value Questionnaire (PVQ). However, the PVQ has not yet been adapted and applied to measure values most relevant to understand environmental beliefs and behaviors. Therefore, we tested the Environmental-PVQ (E-PVQ) – a PVQ variant of E-SVS –and compared it with the E-SVS in two studies. Our findings provide strong support for the validity and reliability of both the E-SVS and E-PVQ. In addition, we find that respondents slightly preferred the E-PVQ over the E-SVS (Study 1). In general, both scales correlate similarly to environmental self-identity (Study 1), energy behaviors (Studies 1 and 2), pro-environmental personal norms, climate change beliefs and policy support (Study 2). Accordingly, both methodologies show highly similar results and seem well-suited for measuring human values underlying environmental behaviors and beliefs. PMID:29743874

  5. English Value-Added Measures: Examining the Limitations of School Performance Measurement

    ERIC Educational Resources Information Center

    Perry, Thomas

    2016-01-01

    Value-added "Progress" measures are to be introduced for all English schools in 2016 as "headline" measures of school performance. This move comes despite research highlighting high levels of instability in value-added measures and concerns about the omission of contextual variables in the planned measure. This article studies…

  6. Measurement Invariance of Expectancy-Value Questionnaire in Physical Education

    ERIC Educational Resources Information Center

    Zhu, Xihe; Sun, Haichun; Chen, Ang; Ennis, Catherine

    2012-01-01

    Expectancy-Value Questionnaire (EVQ) measures student expectancy beliefs and task values of the domain content (Eccles & Wigfield, 1995). In this study the authors examine measurement invariance of EVQ in the domain of physical education between elementary and middle-school students. Participants included 811 students (3rd-5th grades) from 13…

  7. [Implicit value judgments in the measurement of health inequalities].

    PubMed

    Harper, Sam; King, Nicholas B; Meersman, Stephen C; E Reichman, Marsha; Breen, Nancy; Lynch, John

    2014-04-01

    Quantitative estimates of the magnitude, direction, and rate of change of health inequalities play a crucial role in creating and assessing policies aimed at eliminating the disproportionate burden of disease in disadvantaged populations. It is generally assumed that the measurement of health inequalities is a value-neutral process, providing objective data that are then interpreted using normative judgments about whether a particular distribution of health is just, fair, or socially acceptable. We discuss five examples in which normative judgments play a role in the measurement process itself, through either the selection of one measurement strategy to the exclusion of others or the selection of the type, significance, or weight assigned to the variables being measured. Overall, we find that many commonly used measures of inequality are value laden and that the normative judgments implicit in these measures have important consequences for interpreting and responding to health inequalities. Because values implicit in the generation of health inequality measures may lead to radically different interpretations of the same underlying data,we urge researchers to explicitly consider and transparently discuss the normative judgments underlying their measures. We also urge policymakers and other consumers of health inequalities data to pay close attention to the measures on which they base their assessments of current and future health policies.

  8. Implicit value judgments in the measurement of health inequalities.

    PubMed

    Harper, Sam; King, Nicholas B; Meersman, Stephen C; Reichman, Marsha E; Breen, Nancy; Lynch, John

    2010-03-01

    Quantitative estimates of the magnitude, direction, and rate of change of health inequalities play a crucial role in creating and assessing policies aimed at eliminating the disproportionate burden of disease in disadvantaged populations. It is generally assumed that the measurement of health inequalities is a value-neutral process, providing objective data that are then interpreted using normative judgments about whether a particular distribution of health is just, fair, or socially acceptable. We discuss five examples in which normative judgments play a role in the measurement process itself, through either the selection of one measurement strategy to the exclusion of others or the selection of the type, significance, or weight assigned to the variables being measured. Overall, we find that many commonly used measures of inequality are value laden and that the normative judgments implicit in these measures have important consequences for interpreting and responding to health inequalities. Because values implicit in the generation of health inequality measures may lead to radically different interpretations of the same underlying data, we urge researchers to explicitly consider and transparently discuss the normative judgments underlying their measures. We also urge policymakers and other consumers of health inequalities data to pay close attention to the measures on which they base their assessments of current and future health policies.

  9. Heisenberg's uncertainty principle for simultaneous measurement of positive-operator-valued measures

    NASA Astrophysics Data System (ADS)

    Miyadera, Takayuki; Imai, Hideki

    2008-11-01

    A limitation on simultaneous measurement of two arbitrary positive-operator-valued measures is discussed. In general, simultaneous measurement of two noncommutative observables is only approximately possible. Following Werner’s formulation, we introduce a distance between observables to quantify an accuracy of measurement. We derive an inequality that relates the achievable accuracy with noncommutativity between two observables. As a byproduct a necessary condition for two positive-operator-valued measures to be simultaneously measurable is obtained.

  10. A Framework for Measuring Low-Value Care.

    PubMed

    Miller, George; Rhyan, Corwin; Beaudin-Seiler, Beth; Hughes-Cromwick, Paul

    2018-04-01

    It has been estimated that more than 30% of health care spending in the United States is wasteful, and that low-value care, which drives up costs unnecessarily while increasing patient risk, is a significant component of wasteful spending. To address the need for an ability to measure the magnitude of low-value care nationwide, identify the clinical services that are the greatest contributors to waste, and track progress toward eliminating low-value use of these services. Such an ability could provide valuable input to the efforts of policymakers and health systems to improve efficiency. We reviewed existing methods that could contribute to measuring low-value care and developed an integrated framework that combines multiple methods to comprehensively estimate and track the magnitude and principal sources of clinical waste. We also identified a process and needed research for implementing the framework. A comprehensive methodology for measuring and tracking low-value care in the United States would provide an important contribution toward reducing waste. Implementation of the framework described in this article appears feasible, and the proposed research program will allow moving incrementally toward full implementation while providing a near-term capability for measuring low-value care that can be enhanced over time. Copyright © 2018 International Society for Pharmacoeconomics and Outcomes Research (ISPOR). Published by Elsevier Inc. All rights reserved.

  11. Measuring Incompatible Observables by Exploiting Sequential Weak Values.

    PubMed

    Piacentini, F; Avella, A; Levi, M P; Gramegna, M; Brida, G; Degiovanni, I P; Cohen, E; Lussana, R; Villa, F; Tosi, A; Zappa, F; Genovese, M

    2016-10-21

    One of the most intriguing aspects of quantum mechanics is the impossibility of measuring at the same time observables corresponding to noncommuting operators, because of quantum uncertainty. This impossibility can be partially relaxed when considering joint or sequential weak value evaluation. Indeed, weak value measurements have been a real breakthrough in the quantum measurement framework that is of the utmost interest from both a fundamental and an applicative point of view. In this Letter, we show how we realized for the first time a sequential weak value evaluation of two incompatible observables using a genuine single-photon experiment. These (sometimes anomalous) sequential weak values revealed the single-operator weak values, as well as the local correlation between them.

  12. Measuring Incompatible Observables by Exploiting Sequential Weak Values

    NASA Astrophysics Data System (ADS)

    Piacentini, F.; Avella, A.; Levi, M. P.; Gramegna, M.; Brida, G.; Degiovanni, I. P.; Cohen, E.; Lussana, R.; Villa, F.; Tosi, A.; Zappa, F.; Genovese, M.

    2016-10-01

    One of the most intriguing aspects of quantum mechanics is the impossibility of measuring at the same time observables corresponding to noncommuting operators, because of quantum uncertainty. This impossibility can be partially relaxed when considering joint or sequential weak value evaluation. Indeed, weak value measurements have been a real breakthrough in the quantum measurement framework that is of the utmost interest from both a fundamental and an applicative point of view. In this Letter, we show how we realized for the first time a sequential weak value evaluation of two incompatible observables using a genuine single-photon experiment. These (sometimes anomalous) sequential weak values revealed the single-operator weak values, as well as the local correlation between them.

  13. Comparison of measurement- and proxy-based Vs30 values in California

    USGS Publications Warehouse

    Yong, Alan K.

    2016-01-01

    This study was prompted by the recent availability of a significant amount of openly accessible measured VS30 values and the desire to investigate the trend of using proxy-based models to predict VS30 in the absence of measurements. Comparisons between measured and model-based values were performed. The measured data included 503 VS30 values collected from various projects for 482 seismographic station sites in California. Six proxy-based models—employing geologic mapping, topographic slope, and terrain classification—were also considered. Included was a new terrain class model based on the Yong et al. (2012) approach but recalibrated with updated measured VS30 values. Using the measured VS30 data as the metric for performance, the predictive capabilities of the six models were determined to be statistically indistinguishable. This study also found three models that tend to underpredict VS30 at lower velocities (NEHRP Site Classes D–E) and overpredict at higher velocities (Site Classes B–C).

  14. Diversifying natural resources value measurements: The Trinity River study

    USGS Publications Warehouse

    Taylor, J.G.; Douglas, A.J.

    1999-01-01

    An interdisciplinary team set out to establish the economic and social values of the Trinity River in northern California. This information was intended to support the Secretary of the Interior's decision on allocation of Trinity River flows. This team set out to measure the values of Trinity River flows, fishery resources, and recreation amenities in several different ways. A survey was mailed to users of the Trinity River. This single instrument included economic measures (willingness-to-pay and costs incurred in visiting) and social-psychological measures (importance, satisfaction, and water allocation preferences). A closely related survey measured several of these same values among west coast regional households. The results of these surveys were compiled, and the measured economic and social values were compared. We found that integrating economic and social value information provides a greater depth of understanding of the resource's value. In addition, this integration provides a more in-depth understanding through the quantitative and qualitative results that emerge.

  15. A Scaled-Projective Measure of Interpersonal Values

    ERIC Educational Resources Information Center

    Kilmann, Ralph H.

    1975-01-01

    The Kilmann Insight Test is a measure of the interpersonal value constructs. That is how the individual perceives and interprets the desirable and undesirable features of interpersonal behavior. The validity of the test is investigated by explaining its relationship to a self-report measure assessing similar values. (DEP)

  16. Redox potential - field measurements - meassured vs. expected values

    NASA Astrophysics Data System (ADS)

    Stavělová, Monika; Kovář, Martin

    2016-04-01

    Oxidation and reduction (redox) potential is an important and theoretically very well defined parameter and can be calculated accurately. Its value is determinative for management of many electrochemical processes, chemical redox technologies as well as biotechnologies. To measure the redox value that would correspond with the accuracy level of theoretical calculations in field or operational conditions is however nearly impossible. Redox is in practice measured using combined argentochloride electrode with subsequent value conversion to standard hydrogen electrode (EH). Argentochloride electrode does not allow for precise calibration. Prior to the measurement the accuracy of measurement of particular electrode can only be verified in comparative/control solution with value corresponding with oxic conditions (25°C: +220 mV argentochloride electrode, i.e.. +427 mV after conversion to EH). A commercial product of stabile comparative solution for anoxic conditions is not available and therefore not used in every day practice - accuracy of negative redox is not verified. In this presentation results of two tests will be presented: a) monitoring during dynamic groundwater sampling from eight monitoring wells at a site contaminated by chlorinated ethenes (i.e. post-oxic to anoxic conditions) and b) laboratory test of groundwater contaminated by arsenic from two sites during reaction with highly oxidized compounds of iron (ferrates) - i.e. strongly oxic conditions. In both tests a simultaneous measurement by four argentochloride electrodes was implemented - all four electrodes were prior to the test maintained expertly. The redox values of testing electrodes in a comparative solution varied by max. 6 mV. The redox values measured by four electrodes in both anoxic and oxic variant varied by tens to a hundred mV, while with growing time of test the variance of measured redox values increased in both oxic and anoxic variant. Therefore the interpretation of measured redox

  17. One Moon, many measurements 1: Radiance values

    NASA Astrophysics Data System (ADS)

    Pieters, C. M.; Boardman, J. W.; Ohtake, M.; Matsunaga, T.; Haruyama, J.; Green, R. O.; Mall, U.; Staid, M. I.; Isaacson, P. J.; Yokota, Y.; Yamamoto, S.; Besse, S.; Sunshine, J. M.

    2013-09-01

    Several modern optical instruments orbited the Moon during 2008 and 2009 onboard the SELENE and Chandrayaan-1 spacecraft and provided a welcomed feast of spectroscopic data to be used for scientific analyses. The different spatial and spectral resolutions of these sensors along with diverse illumination geometry during data acquisition make each set of data unique, and each instrument contributes special value to integrated science analyses. In order to provide the maximum science benefit, we have undertaken a careful cross-validation of radiance data among these orbital instruments and also a set of systematic data acquired using Earth-based telescopes. Most radiance values at 750 nm fall between 0 and 100 W/(m2 μm sr), but a small important fraction can be up to ×2 to ×3 that value, with the largest values occurring at the highest spatial resolution. All instruments are in agreement about overall spectral properties of lunar materials, but small systematic differences are documented between instruments. Lunar radiance values measured with remote sensors for landing sites are all not as high as that estimated from laboratory measurements of returned soil. This is largely because laboratory measurements of lunar soils cannot retain or duplicate the fine structure of lunar regolith found in the natural space environment.

  18. Weak values in continuous weak measurements of qubits

    NASA Astrophysics Data System (ADS)

    Qin, Lupei; Liang, Pengfei; Li, Xin-Qi

    2015-07-01

    For continuous weak measurements of qubits, we obtain exact expressions for weak values (WVs) from the postselection restricted average of measurement outputs, by using both the quantum-trajectory equation (QTE) and the quantum Bayesian approach. The former is applicable to short-time weak measurement, while the latter can relax the measurement strength to finite. We find that even in the "very" weak limit the result can be essentially different from the one originally proposed by Aharonov, Albert, and Vaidman (AAV), in the sense that our result incorporates nonperturbative correction which could be important when the AAV WV is large. Within the Bayesian framework, we obtain also elegant expressions for finite measurement strength and find that the amplifier's noise in quantum measurement has no effect on the WVs. In particular, we obtain very useful results for homodyne measurement in a circuit-QED system, which allows for measuring the real and imaginary parts of the AAV WV by simply tuning the phase of the local oscillator. This advantage can be exploited as an efficient state-tomography technique.

  19. Complex Fuzzy Set-Valued Complex Fuzzy Measures and Their Properties

    PubMed Central

    Ma, Shengquan; Li, Shenggang

    2014-01-01

    Let F*(K) be the set of all fuzzy complex numbers. In this paper some classical and measure-theoretical notions are extended to the case of complex fuzzy sets. They are fuzzy complex number-valued distance on F*(K), fuzzy complex number-valued measure on F*(K), and some related notions, such as null-additivity, pseudo-null-additivity, null-subtraction, pseudo-null-subtraction, autocontionuous from above, autocontionuous from below, and autocontinuity of the defined fuzzy complex number-valued measures. Properties of fuzzy complex number-valued measures are studied in detail. PMID:25093202

  20. On set-valued functionals: Multivariate risk measures and Aumann integrals

    NASA Astrophysics Data System (ADS)

    Ararat, Cagin

    In this dissertation, multivariate risk measures for random vectors and Aumann integrals of set-valued functions are studied. Both are set-valued functionals with values in a complete lattice of subsets of Rm. Multivariate risk measures are considered in a general d-asset financial market with trading opportunities in discrete time. Specifically, the following features of the market are incorporated in the evaluation of multivariate risk: convex transaction costs modeled by solvency regions, intermediate trading constraints modeled by convex random sets, and the requirement of liquidation into the first m ≤ d of the assets. It is assumed that the investor has a "pure" multivariate risk measure R on the space of m-dimensional random vectors which represents her risk attitude towards the assets but does not take into account the frictions of the market. Then, the investor with a d-dimensional position minimizes the set-valued functional R over all m-dimensional positions that she can reach by trading in the market subject to the frictions described above. The resulting functional Rmar on the space of d-dimensional random vectors is another multivariate risk measure, called the market-extension of R. A dual representation for R mar that decomposes the effects of R and the frictions of the market is proved. Next, multivariate risk measures are studied in a utility-based framework. It is assumed that the investor has a complete risk preference towards each individual asset, which can be represented by a von Neumann-Morgenstern utility function. Then, an incomplete preference is considered for multivariate positions which is represented by the vector of the individual utility functions. Under this structure, multivariate shortfall and divergence risk measures are defined as the optimal values of set minimization problems. The dual relationship between the two classes of multivariate risk measures is constructed via a recent Lagrange duality for set optimization. In

  1. A framework to measure the value of public health services.

    PubMed

    Jacobson, Peter D; Neumann, Peter J

    2009-10-01

    To develop a framework that public health practitioners could use to measure the value of public health services. Primary data were collected from August 2006 through March 2007. We interviewed (n=46) public health practitioners in four states, leaders of national public health organizations, and academic researchers. Using a semi-structured interview protocol, we conducted a series of qualitative interviews to define the component parts of value for public health services and identify methodologies used to measure value and data collected. The primary form of analysis is descriptive, synthesizing information across respondents as to how they measure the value of their services. Our interviews did not reveal a consensus on how to measure value or a specific framework for doing so. Nonetheless, the interviews identified some potential strategies, such as cost accounting and performance-based contracting mechanisms. The interviews noted implementation barriers, including limits to staff capacity and data availability. We developed a framework that considers four component elements to measure value: external factors that must be taken into account (i.e., mandates); key internal actions that a local health department must take (i.e., staff assessment); using appropriate quantitative measures; and communicating value to elected officials and the public.

  2. Prognostic and diagnostic value of EEG signal coupling measures in coma.

    PubMed

    Zubler, Frederic; Koenig, Christa; Steimer, Andreas; Jakob, Stephan M; Schindler, Kaspar A; Gast, Heidemarie

    2016-08-01

    Our aim was to assess the diagnostic and predictive value of several quantitative EEG (qEEG) analysis methods in comatose patients. In 79 patients, coupling between EEG signals on the left-right (inter-hemispheric) axis and on the anterior-posterior (intra-hemispheric) axis was measured with four synchronization measures: relative delta power asymmetry, cross-correlation, symbolic mutual information and transfer entropy directionality. Results were compared with etiology of coma and clinical outcome. Using cross-validation, the predictive value of measure combinations was assessed with a Bayes classifier with mixture of Gaussians. Five of eight measures showed a statistically significant difference between patients grouped according to outcome; one measure revealed differences in patients grouped according to the etiology. Interestingly, a high level of synchrony between the left and right hemisphere was associated with mortality on intensive care unit, whereas higher synchrony between anterior and posterior brain regions was associated with survival. The combination with the best predictive value reached an area-under the curve of 0.875 (for patients with post anoxic encephalopathy: 0.946). EEG synchronization measures can contribute to clinical assessment, and provide new approaches for understanding the pathophysiology of coma. Prognostication in coma remains a challenging task. qEEG could improve current multi-modal approaches. Copyright © 2015 International Federation of Clinical Neurophysiology. Published by Elsevier Ireland Ltd. All rights reserved.

  3. Weak measurements and quantum weak values for NOON states

    NASA Astrophysics Data System (ADS)

    Rosales-Zárate, L.; Opanchuk, B.; Reid, M. D.

    2018-03-01

    Quantum weak values arise when the mean outcome of a weak measurement made on certain preselected and postselected quantum systems goes beyond the eigenvalue range for a quantum observable. Here, we propose how to determine quantum weak values for superpositions of states with a macroscopically or mesoscopically distinct mode number, that might be realized as two-mode Bose-Einstein condensate or photonic NOON states. Specifically, we give a model for a weak measurement of the Schwinger spin of a two-mode NOON state, for arbitrary N . The weak measurement arises from a nondestructive measurement of the two-mode occupation number difference, which for atomic NOON states might be realized via phase contrast imaging and the ac Stark effect using an optical meter prepared in a coherent state. The meter-system coupling results in an entangled cat-state. By subsequently evolving the system under the action of a nonlinear Josephson Hamiltonian, we show how postselection leads to quantum weak values, for arbitrary N . Since the weak measurement can be shown to be minimally invasive, the weak values provide a useful strategy for a Leggett-Garg test of N -scopic realism.

  4. Measuring Children's Environmental Attitudes and Values in Northwest Mexico: Validating a Modified Version of Measures to Test the Model of Ecological Values (2-MEV)

    ERIC Educational Resources Information Center

    Schneller, A. J.; Johnson, B.; Bogner, F. X.

    2015-01-01

    This paper describes the validation process of measuring children's attitudes and values toward the environment within a Mexican sample. We applied the Model of Ecological Values (2-MEV), which has been shown to be valid and reliable in 20 countries, including one Spanish speaking culture. Items were initially modified to fit the regional dialect,…

  5. Intensity-Value Corrections for Integrating Sphere Measurements of Solid Samples Measured Behind Glass

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Johnson, Timothy J.; Bernacki, Bruce E.; Redding, Rebecca L.

    2014-11-01

    Accurate and calibrated directional-hemispherical reflectance spectra of solids are important for both in situ and remote sensing. Many solids are in the form of powders or granules and to measure their diffuse reflectance spectra in the laboratory, it is often necessary to place the samples behind a transparent medium such as glass for the ultraviolet (UV), visible, or near-infrared spectral regions. Using both experimental methods and a simple optical model, we demonstrate that glass (fused quartz in our case) leads to artifacts in the reflectance values. We report our observations that the measured reflectance values, for both hemispherical and diffusemore » reflectance, are distorted by the additional reflections arising at the air–quartz and sample–quartz interfaces. The values are dependent on the sample reflectance and are offset in intensity in the hemispherical case, leading to measured values up to ~6% too high for a 2% reflectance surface, ~3.8% too high for 10% reflecting surfaces, approximately correct for 40–60% diffuse-reflecting surfaces, and ~1.5% too low for 99% reflecting Spectralon® surfaces. For the case of diffuse-only reflectance, the measured values are uniformly too low due to the polished glass, with differences of nearly 6% for a 99% reflecting matte surface. The deviations arise from the added reflections from the quartz surfaces, as verified by both theory and experiment, and depend on sphere design. Finally, empirical correction factors were implemented into post-processing software to redress the artifact for hemispherical and diffuse reflectance data across the 300–2300 nm range.« less

  6. Spectral dilation of L(B,H)-valued measures and its application to stationary dilation for Banach space valued processes

    NASA Technical Reports Server (NTRS)

    Miamee, A. G.

    1988-01-01

    Let B be a Banach space and H and K two Hilbert spaces. The spectral dilation of L(B,H)-valued measures is studied and it is shown that the recent results of Makagon and Salehi (1986) and Rosenberg (1982) on the dilation of L(K,H)-valued measures can be extended to hold for the general Banach space setting of L(B,H)-valued measures. These L(B,H)-valued measures are closely connected to the Banach space valued processes. This connection is recalled and as application of spectral dilation of L(B,H)-valued measures the well known stationary dilation results for scalar valued processes is extended to the case of Banach space valued processes.

  7. Precise Penning trap measurements of double β-decay Q-values

    NASA Astrophysics Data System (ADS)

    Redshaw, M.; Brodeur, M.; Bollen, G.; Bustabad, S.; Eibach, M.; Gulyuz, K.; Izzo, C.; Lincoln, D. L.; Novario, S. J.; Ringle, R.; Sandler, R.; Schwarz, S.; Valverde, A. A.

    2015-10-01

    The double β-decay (ββ -decay) Q-value, defined as the mass difference between parent and daughter atoms, is an important parameter for both two-neutrino ββ -decay (2 νββ) and neutrinoless ββ -decay (0 νββ) experiments. The Q-value enters into the calculation of the phase space factors, which relate the measured ββ -decay half-life to the nuclear matrix element and, in the case of 0 νββ , the effective Majorana mass of the neutrino. In addition, the Q-value defines the total kinetic energy of the two electrons emitted in 0 νββ , corresponding to the location of the single peak that is the sought after signature of 0 νββ . Hence, it is essential to have a precise and accurate Q-value determination. Over the last decade, the Penning trap mass spectrometry community has made a significant effort to provide precise ββ -decay Q-value determinations. Here we report on recent measurements with the Low Energy Beam and Ion Trap (LEBIT) facility at the National Superconducting Cyclotron Laboratory (NSCL) of the 48Ca, 82Se, and 96Zr Q-values. These measurements complete the determination of ββ -decay Q-values for the 11 ``best'' candidates (those with Q >2 MeV). We also report on a measurement of the 78Kr double electron capture (2EC) Q-value and discuss ongoing Penning trap measurements relating to ββ -decay and 2EC. Support from NSF Contract No. PHY-1102511, and DOE Grant No. 03ER-41268.

  8. Mathematical values in the processing of Chinese numeral classifiers and measure words.

    PubMed

    Her, One-Soon; Chen, Ying-Chun; Yen, Nai-Shing

    2017-01-01

    A numeral classifier is required between a numeral and a noun in Chinese, which comes in two varieties, sortal classifer (C) and measural classifier (M), also known as 'classifier' and 'measure word', respectively. Cs categorize objects based on semantic attributes and Cs and Ms both denote quantity in terms of mathematical values. The aim of this study was to conduct a psycholinguistic experiment to examine whether participants process C/Ms based on their mathematical values with a semantic distance comparison task, where participants judged which of the two C/M phrases was semantically closer to the target C/M. Results showed that participants performed more accurately and faster for C/Ms with fixed values than the ones with variable values. These results demonstrated that mathematical values do play an important role in the processing of C/Ms. This study may thus shed light on the influence of the linguistic system of C/Ms on magnitude cognition.

  9. Implementing Value-Added Measures of School Effectiveness: Getting the Incentives Right.

    ERIC Educational Resources Information Center

    Ladd, Helen F.; Walsh, Randall P.

    2002-01-01

    Evaluates value-added approach to measuring school effectiveness in North and South Carolina. Finds that value-added approach favors high-achievement schools, with large percentage of students from high-SES backgrounds. Discusses statistical problems in measuring value added. Concludes teachers' and administrators' avoidance of low-achievement,…

  10. Reference values for physical performance measures in the aging working population.

    PubMed

    Cote, Mark P; Kenny, Anne; Dussetschleger, Jeffrey; Farr, Dana; Chaurasia, Ashok; Cherniack, Martin

    2014-02-01

    The aim of this study was to determine reference physical performance values in older aging workers. Cross-sectional physical performance measures were collected for 736 manufacturing workers to assess effects of work and nonwork factors on age-related changes in musculoskeletal function and health. Participants underwent surveys and physical testing that included bioelectrical impedance analysis, range-of-motion measures, exercise testing, and dynamic assessment. Physical characteristics, such as blood pressure and body fat percentage, were comparable to published values. Dynamic and range-of-motion measurements differed from published normative results. Women had age-related decreases in cervical extension and lateral rotation. Older men had better spinal flexion than expected. Predicted age-related decline in lower-extremity strength and shoulder strength in women was not seen. Men declined in handgrip, lower-extremity strength, and knee extension strength, but not trunk strength, across age groups. There was no appreciable decline in muscle fatigue at the trunk, shoulder, and knee with aging for either gender, except for the youngest age group of women. Normative values may underestimate physical performance in "healthy" older workers, thereby underappreciating declines in less healthy older workers. Work may be preservative of function for a large group of selected individuals. A "healthy worker effect" may be greater for musculoskeletal disease and function than for heart disease and mortality. Clinicians and researchers studying musculoskeletal function in older workers can use a more specific set of reference values.

  11. Measuring energy efficiency in economics: Shadow value approach

    NASA Astrophysics Data System (ADS)

    Khademvatani, Asgar

    For decades, academic scholars and policy makers have commonly applied a simple average measure, energy intensity, for studying energy efficiency. In contrast, we introduce a distinctive marginal measure called energy shadow value (SV) for modeling energy efficiency drawn on economic theory. This thesis demonstrates energy SV advantages, conceptually and empirically, over the average measure recognizing marginal technical energy efficiency and unveiling allocative energy efficiency (energy SV to energy price). Using a dual profit function, the study illustrates how treating energy as quasi-fixed factor called quasi-fixed approach offers modeling advantages and is appropriate in developing an explicit model for energy efficiency. We address fallacies and misleading results using average measure and demonstrate energy SV advantage in inter- and intra-country energy efficiency comparison. Energy efficiency dynamics and determination of efficient allocation of energy use are shown through factors impacting energy SV: capital, technology, and environmental obligations. To validate the energy SV, we applied a dual restricted cost model using KLEM dataset for the 35 US sectors stretching from 1958 to 2000 and selected a sample of the four sectors. Following the empirical results, predicted wedges between energy price and the SV growth indicate a misallocation of energy use in stone, clay and glass (SCG) and communications (Com) sectors with more evidence in the SCG compared to the Com sector, showing overshoot in energy use relative to optimal paths and cost increases from sub-optimal energy use. The results show that energy productivity is a measure of technical efficiency and is void of information on the economic efficiency of energy use. Decomposing energy SV reveals that energy, capital and technology played key roles in energy SV increases helping to consider and analyze policy implications of energy efficiency improvement. Applying the marginal measure, we also

  12. Patients’ perceived value of pharmacy quality measures: a mixed-methods study

    PubMed Central

    Shiyanbola, Olayinka O; Mort, Jane R

    2015-01-01

    Objective To describe patients’ perceived value and use of quality measures in evaluating and choosing community pharmacies. Design Focus group methodology was combined with a survey tool. During the focus groups, participants assessed the value of the Pharmacy Quality Alliance's quality measures in evaluating and choosing a pharmacy. Also, participants completed questionnaires rating their perceived value of quality measures in evaluating a pharmacy (1 being low value and 5 being high) or choosing a pharmacy (yes/no). Thematic analysis and descriptive statistics were used to analyse the focus groups and surveys, respectively. Setting Semistructured focus groups were conducted in a private meeting space of an urban and a rural area of a Mid-western State in the USA. Participants Thirty-four adults who filled prescription medications in community pharmacies for a chronic illness were recruited in community pharmacies, senior centres and public libraries. Results While comments indicated that all measures were important, medication safety measures (eg, drug-drug interactions) were valued more highly than others. Rating of quality measure utility in evaluating a pharmacy ranged from a mean of 4.88 (‘drug-drug interactions’) to a mean of 4.0 (‘absence of controller therapy for patients with asthma’). Patients were hesitant to use quality information in choosing a pharmacy (depending on the participant's location) but might consider if moving to a new area or having had a negative pharmacy experience. Use of select quality measures to choose a pharmacy ranged from 97.1% of participants using ‘drug-drug interactions’ (medication safety measure) to 55.9% using ‘absence of controller therapy for patients with asthma’. Conclusions The study participants valued quality measures in evaluating and selecting a community pharmacy, with medication safety measures valued highest. The participants reported that the quality measures would not typically cause a

  13. Development and Preliminary Validation of a New Measure of Values in Scientific Work.

    PubMed

    English, Tammy; Antes, Alison L; Baldwin, Kari A; DuBois, James M

    2018-04-01

    In this paper we describe the development and initial psychometric evaluation of a new measure, the values in scientific work (VSW). This scale assesses the level of importance that investigators attach to different VSW. It taps a broad range of intrinsic, extrinsic, and social values that motivate the work of scientists, including values specific to scientific work (e.g., truth and integrity) and more classic work values (e.g., security and prestige) in the context of science. Notably, the values represented in this scale are relevant to scientists regardless of their career stage and research focus. We administered the VSW and a measure of global values to 203 NIH-funded investigators. Exploratory factor analyses suggest the delineation of eight VSW, including autonomy, research ethics, social impact, income, collaboration, innovation and growth, conserving relationships, and job security. These VSW showed predictable and distinct associations with global values. Implications of these findings for work on research integrity and scientific misconduct are discussed.

  14. Cultural Values Predicting Acculturation Orientations: Operationalizing a Quantitative Measure

    ERIC Educational Resources Information Center

    Ehala, Martin

    2012-01-01

    This article proposes that acculturation orientations are related to two sets of cultural values: utilitarianism (Ut) and traditionalism (Tr). While utilitarian values enhance assimilation, traditional values support language and identity maintenance. It is proposed that the propensity to either end of this value opposition can be measured by an…

  15. A National Trial on Differences in Cerebral Perfusion Pressure Values by Measurement Location.

    PubMed

    McNett, Molly M; Bader, Mary Kay; Livesay, Sarah; Yeager, Susan; Moran, Cristina; Barnes, Arianna; Harrison, Kimberly R; Olson, DaiWai M

    2018-04-01

    Cerebral perfusion pressure (CPP) is a key parameter in management of brain injury with suspected impaired cerebral autoregulation. CPP is calculated by subtracting intracranial pressure (ICP) from mean arterial pressure (MAP). Despite consensus on importance of CPP monitoring, substantial variations exist on anatomical reference points used to measure arterial MAP when calculating CPP. This study aimed to identify differences in CPP values based on measurement location when using phlebostatic axis (PA) or tragus (Tg) as anatomical reference points. The secondary study aim was to determine impact of differences on patient outcomes at discharge. This was a prospective, repeated measures, multi-site national trial. Adult ICU patients with neurological injury necessitating ICP and CPP monitoring were consecutively enrolled from seven sites. Daily MAP/ICP/CPP values were gathered with the arterial transducer at the PA, followed by the Tg as anatomical reference points. A total of 136 subjects were enrolled, resulting in 324 paired observations. There were significant differences for CPP when comparing values obtained at PA and Tg reference points (p < 0.000). Differences remained significant in repeated measures model when controlling for clinical factors (mean CPP-PA = 80.77, mean CPP-Tg = 70.61, p < 0.000). When categorizing CPP as binary endpoint, 18.8% of values were identified as adequate with PA values, yet inadequate with CPP values measured at the Tg. Findings identify numerical differences for CPP based on anatomical reference location and highlight importance of a standard reference point for both clinical practice and future trials to limit practice variations and heterogeneity of findings.

  16. The Development and Validation of Brief and Ultrabrief Measures of Values.

    PubMed

    Sandy, Carson J; Gosling, Samuel D; Schwartz, Shalom H; Koelkebeck, Tim

    2017-01-01

    Values are a central personality construct and the importance of studying them has been well established. To encourage researchers to integrate measures of values into their studies, brief and ultrabrief instruments were developed to recapture the 10 values measured by the 40-item Portrait Values Questionnaire (PVQ; Schwartz, 2003 ). Rigorous psychometric procedures based on separate derivation (N = 38,049) and evaluation (N = 29,143) samples yielded 10- and 20-item measures of values, which proved to be successful at capturing the patterns and magnitude of correlations associated with the original PVQ. These instruments should be useful to researchers who would like to incorporate a values scale into their study but do not have the space to administer a longer measure.

  17. Measurement Theory Based on the Truth Values Violates Local Realism

    NASA Astrophysics Data System (ADS)

    Nagata, Koji

    2017-02-01

    We investigate the violation factor of the Bell-Mermin inequality. Until now, we use an assumption that the results of measurement are ±1. In this case, the maximum violation factor is 2( n-1)/2. The quantum predictions by n-partite Greenberger-Horne-Zeilinger (GHZ) state violate the Bell-Mermin inequality by an amount that grows exponentially with n. Recently, a new measurement theory based on the truth values is proposed (Nagata and Nakamura, Int. J. Theor. Phys. 55:3616, 2016). The values of measurement outcome are either +1 or 0. Here we use the new measurement theory. We consider multipartite GHZ state. It turns out that the Bell-Mermin inequality is violated by the amount of 2( n-1)/2. The measurement theory based on the truth values provides the maximum violation of the Bell-Mermin inequality.

  18. Measure-valued solutions to the complete Euler system revisited

    NASA Astrophysics Data System (ADS)

    Březina, Jan; Feireisl, Eduard

    2018-06-01

    We consider the complete Euler system describing the time evolution of a general inviscid compressible fluid. We introduce a new concept of measure-valued solution based on the total energy balance and entropy inequality for the physical entropy without any renormalization. This class of so-called dissipative measure-valued solutions is large enough to include the vanishing dissipation limits of the Navier-Stokes-Fourier system. Our main result states that any sequence of weak solutions to the Navier-Stokes-Fourier system with vanishing viscosity and heat conductivity coefficients generates a dissipative measure-valued solution of the Euler system under some physically grounded constitutive relations. Finally, we discuss the same asymptotic limit for the bi-velocity fluid model introduced by H.Brenner.

  19. Bayes' theorem application in the measure information diagnostic value assessment

    NASA Astrophysics Data System (ADS)

    Orzechowski, Piotr D.; Makal, Jaroslaw; Nazarkiewicz, Andrzej

    2006-03-01

    The paper presents Bayesian method application in the measure information diagnostic value assessment that is used in the computer-aided diagnosis system. The computer system described here has been created basing on the Bayesian Network and is used in Benign Prostatic Hyperplasia (BPH) diagnosis. The graphic diagnostic model enables to juxtapose experts' knowledge with data.

  20. Can the reinforcing value of food be measured in bulimia nervosa?

    PubMed Central

    Schebendach, Janet; Broft, Allegra; Foltin, Richard W.; Walsh, B. Timothy

    2013-01-01

    Binge eating is a core clinical feature of bulimia nervosa (BN). Enhanced reinforcing value of food may play a role in this behavioral disturbance, but a systematic behavioral assessment of objective measures of the rewarding value of binge eating is lacking. The purpose of this study was to quantify the reinforcing value of food in BN patients as compared with normal controls. A progressive ratio (PR) computerized work task was completed under binge and non-binge instruction. The task consisted of 12 trials. The first trial required 50 keyboard taps to earn one portion of yogurt shake, and subsequent trials required progressive work increments of 200 taps for each additional portion. Completion of all 12 trials required 13,800 taps to earn 2,100 ml of shake. The breakpoint, defined as the largest ratio completed before a participant stopped working, was the measure of reinforcing efficacy. Ten patients and 10 controls completed the experiment. Under binge instruction, patients completed more trials and taps, and had a higher breakpoint than controls. The non-binge instruction yielded opposite findings; compared to controls, patients completed fewer trials and taps, and had a lower breakpoint. These results support the feasibility and potential utility of a PR task to quantify the reinforcing value of food in patients with BN. PMID:23178173

  1. Can the reinforcing value of food be measured in bulimia nervosa?

    PubMed

    Schebendach, Janet; Broft, Allegra; Foltin, Richard W; Walsh, B Timothy

    2013-03-01

    Binge eating is a core clinical feature of bulimia nervosa (BN). Enhanced reinforcing value of food may play a role in this behavioral disturbance, but a systematic behavioral assessment of objective measures of the rewarding value of binge eating is lacking. The purpose of this study was to quantify the reinforcing value of food in BN patients as compared with normal controls. A progressive ratio (PR) computerized work task was completed under binge and non-binge instruction. The task consisted of 12 trials. The first trial required 50 keyboard taps to earn one portion of yogurt shake, and subsequent trials required progressive work increments of 200 taps for each additional portion. Completion of all 12 trials required 13,800 taps to earn 2100ml of shake. The breakpoint, defined as the largest ratio completed before a participant stopped working, was the measure of reinforcing efficacy. Ten patients and 10 controls completed the experiment. Under binge instruction, patients completed more trials and taps, and had a higher breakpoint than controls. The non-binge instruction yielded opposite findings; compared to controls, patients completed fewer trials and taps, and had a lower breakpoint. These results support the feasibility and potential utility of a PR task to quantify the reinforcing value of food in patients with BN. Copyright © 2012 Elsevier Ltd. All rights reserved.

  2. Direct quantum process tomography via measuring sequential weak values of incompatible observables.

    PubMed

    Kim, Yosep; Kim, Yong-Su; Lee, Sang-Yun; Han, Sang-Wook; Moon, Sung; Kim, Yoon-Ho; Cho, Young-Wook

    2018-01-15

    The weak value concept has enabled fundamental studies of quantum measurement and, recently, found potential applications in quantum and classical metrology. However, most weak value experiments reported to date do not require quantum mechanical descriptions, as they only exploit the classical wave nature of the physical systems. In this work, we demonstrate measurement of the sequential weak value of two incompatible observables by making use of two-photon quantum interference so that the results can only be explained quantum physically. We then demonstrate that the sequential weak value measurement can be used to perform direct quantum process tomography of a qubit channel. Our work not only demonstrates the quantum nature of weak values but also presents potential new applications of weak values in analyzing quantum channels and operations.

  3. CAN CONTINGENT VALUATION MEASURE PASSIVE USE VALUES

    EPA Science Inventory

    Contingent valuation (CV) is the only method currently available for practically measuring passive-use values. Because proposed laws may require that environmental regulations pass a benefit-cost test, CV has become central to the policy debate on environmental protection. Crit...

  4. The Valued Living Questionnaire: Defining and Measuring Valued Action within a Behavioral Framework

    ERIC Educational Resources Information Center

    Wilson, Kelly G.; Sandoz, Emily K.; Kitchens, Jennifer; Roberts, Miguel

    2010-01-01

    A number of cognitive-behavior therapies now strongly emphasize particular behavioral processes as mediators of clinical change specific to that therapy. This shift in emphasis calls for the development of measures sensitive to changes in the therapies' processes. Among these is acceptance and commitment therapy (ACT), which posits valued living…

  5. Measuring changes in lipid and blood glucose values in the health and wellness program of Prudential Financial, Inc.

    PubMed

    Short, Meghan E; Goetzel, Ron Z; Young, Jared S; Kowlessar, Niranjana M; Liss-Levinson, Rivka C; Tabrizi, Maryam J; Roemer, Enid Chung; Sabatelli, Adriano A; Winick, Keith; Montes, Myrtho; Crighton, K Andrew

    2010-08-01

    To determine the effect of health promotion programs of Prudential Financial, Inc on biometric measures of blood lipids and glucose. Using actual biometric and self-reported measures of blood lipids and glucose values for the employees of Prudential Financial, Inc, we examined 1) the extent to which self-reported lipid and blood glucose values correlate to laboratory data, 2) whether self-reported and measured lipid values differ for physically active and sedentary employees, and 3) whether participation in a disease management program affects employees' lipid measures. We found significant differences in self-reported and measured total cholesterol and low-density lipoprotein values, although these differences and those for all lipid and blood glucose values were not clinically meaningful. Supporting previous clinical studies, high-density lipoprotein values were significantly higher for fitness center users compared with sedentary employees. Finally, disease management participants showed a significant reduction in total cholesterol and low-density lipoprotein during a 3-year period compared with nonparticipants. On average, the employees of Prudential Financial, Inc were aware of and accurately reported their lipid and blood glucose levels. Results from this study support the value of evaluating corporate health promotion programs, using measured biometric outcomes.

  6. Measuring Success in Health Care Value-Based Purchasing Programs

    PubMed Central

    Damberg, Cheryl L.; Sorbero, Melony E.; Lovejoy, Susan L.; Martsolf, Grant R.; Raaen, Laura; Mandel, Daniel

    2014-01-01

    Abstract Value-based purchasing (VBP) refers to a broad set of performance-based payment strategies that link financial incentives to health care providers' performance on a set of defined measures in an effort to achieve better value. The U.S. Department of Health and Human Services is advancing the implementation of VBP across an array of health care settings in the Medicare program in response to requirements in the 2010 Patient Protection and Affordable Care Act, and policymakers are grappling with many decisions about how best to design and implement VBP programs so that they are successful in achieving stated goals. This article summarizes the current state of knowledge about VBP based on a review of the published literature, a review of publicly available documentation from VBP programs, and discussions with an expert panel composed of VBP program sponsors, health care providers and health systems, and academic researchers with VBP evaluation expertise. Three types of VBP models were the focus of the review: (1) pay-for-performance programs, (2) accountable care organizations, and (3) bundled payment programs. The authors report on VBP program goals and what constitutes success; the evidence on the impact of these programs; factors that characterize high– and low–performing providers in VBP programs; the measures, incentive structures, and benchmarks used by VBP programs; evidence on spillover effects and unintended consequences; and gaps in the knowledge base. PMID:28083347

  7. The added value of measuring thumb and finger strength when comparing strength measurements in hypoplastic thumb patients.

    PubMed

    Molenaar, H M Ties; Selles, Ruud W; de Kraker, Marjolein; Stam, Henk J; Hovius, Steven E R

    2013-10-01

    When interventions to the hand are aimed at improving function of specific fingers or the thumb, the RIHM (Rotterdam Intrinsic Hand Myometer) is a validated tool and offers more detailed information to assess strength of the involved joints besides grip and pinch measurements. In this study, strength was measured in 65 thumbs in 40 patients diagnosed with thumb hypoplasia. These 65 thumbs were classified according to Blauth. Longitudinal radial deficiencies were also classified. The strength measurements comprised of grip, tip, tripod and key pinch. Furthermore palmar abduction and opposition of the thumb as well as abduction of the index and little finger were measured with the RIHM. For all longitudinal radial deficiency patients, grip and pinch strength as well as palmar abduction and thumb opposition were significantly lower than reference values (P<0.001). However, strength in the index finger abduction and the little finger abduction was maintained or decreased to a lesser extent according to the degree of longitudinal radial deficiency. All strength values decreased with increasing Blauth-type. Blauth-type II hands (n=15) with flexor digitorum superficialis 4 opposition transfer including stabilization of the metacarpophalangeal joint showed a trend toward a higher opposition strength without reaching statistical significance (P=0.094),however compared to non-operated Blauth-type II hands (n=6) they showed a lower grip strength (P=0.019). The RIHM is comparable in accuracy to other strength dynamometers. Using the RIHM, we were able to illustrate strength patterns on finger-specific level, showing added value when evaluating outcome in patients with hand related problems. © 2013.

  8. Added value measures in education show genetic as well as environmental influence.

    PubMed

    Haworth, Claire M A; Asbury, Kathryn; Dale, Philip S; Plomin, Robert

    2011-02-02

    Does achievement independent of ability or previous attainment provide a purer measure of the added value of school? In a study of 4000 pairs of 12-year-old twins in the UK, we measured achievement with year-long teacher assessments as well as tests. Raw achievement shows moderate heritability (about 50%) and modest shared environmental influences (25%). Unexpectedly, we show that for indices of the added value of school, genetic influences remain moderate (around 50%), and the shared (school) environment is less important (about 12%). The pervasiveness of genetic influence in how and how much children learn is compatible with an active view of learning in which children create their own educational experiences in part on the basis of their genetic propensities.

  9. Establishing traceability of photometric absorbance values for accurate measurements of the haemoglobin concentration in blood

    NASA Astrophysics Data System (ADS)

    Witt, K.; Wolf, H. U.; Heuck, C.; Kammel, M.; Kummrow, A.; Neukammer, J.

    2013-10-01

    Haemoglobin concentration in blood is one of the most frequently measured analytes in laboratory medicine. Reference and routine methods for the determination of the haemoglobin concentration in blood are based on the conversion of haeme, haemoglobin and haemiglobin species into uniform end products. The total haemoglobin concentration in blood is measured using the absorbance of the reaction products. Traceable absorbance measurement values on the highest metrological level are a prerequisite for the calibration and evaluation of procedures with respect to their suitability for routine measurements and their potential as reference measurement procedures. For this purpose, we describe a procedure to establish traceability of spectral absorbance measurements for the haemiglobincyanide (HiCN) method and for the alkaline haematin detergent (AHD) method. The latter is characterized by a higher stability of the reaction product. In addition, the toxic hazard of cyanide, which binds to the iron ion of the haem group and thus inhibits the oxygen transport, is avoided. Traceability is established at different wavelengths by applying total least-squares analysis to derive the conventional quantity values for the absorbance from the measured values. Extrapolation and interpolation are applied to get access to the spectral regions required to characterize the Q-absorption bands of the HiCN and AHD methods, respectively. For absorbance values between 0.3 and 1.8, the contributions of absorbance measurements to the total expanded uncertainties (95% level of confidence) of absorbance measurements range from 1% to 0.4%.

  10. [Gas Concentration Measurement Based on the Integral Value of Absorptance Spectrum].

    PubMed

    Liu, Hui-jun; Tao, Shao-hua; Yang, Bing-chu; Deng, Hong-gui

    2015-12-01

    The absorptance spectrum of a gas is the basis for the qualitative and quantitative analysis of the gas by the law of the Lambert-Beer. The integral value of the absorptance spectrum is an important parameter to describe the characteristics of the gas absorption. Based on the measured absorptance spectrum of a gas, we collected the required data from the database of HIT-RAN, and chose one of the spectral lines and calculated the integral value of the absorptance spectrum in the frequency domain, and then substituted the integral value into Lambert-Beer's law to obtain the concentration of the detected gas. By calculating the integral value of the absorptance spectrum we can avoid the more complicated calculation of the spectral line function and a series of standard gases for calibration, so the gas concentration measurement will be simpler and faster. We studied the changing trends of the integral values of the absorptance spectrums versus temperature. Since temperature variation would cause the corresponding variation in pressure, we studied the changing trends of the integral values of the absorptance spectrums versus both the pressure not changed with temperature and changed with the temperature variation. Based on the two cases, we found that the integral values of the absorptance spectrums both would firstly increase, then decrease, and finally stabilize with temperature increasing, but the ranges of specific changing trend were different in the two cases. In the experiments, we found that the relative errors of the integrated values of the absorptance spectrum were much higher than 1% and still increased with temperature when we only considered the change of temperature and completely ignored the pressure affected by the temperature variation, and the relative errors of the integrated values of the absorptance spectrum were almost constant at about only 1% when we considered that the pressure were affected by the temperature variation. As the integral value

  11. Linking Quality and Spending to Measure Value for People with Serious Illness.

    PubMed

    Ryan, Andrew M; Rodgers, Phillip E

    2018-03-01

    Healthcare payment is rapidly evolving to reward value by measuring and paying for quality and spending performance. Rewarding value for the care of seriously ill patients presents unique challenges. To evaluate the state of current efforts to measure and reward value for the care of seriously ill patients. We performed a PubMed search of articles related to (1) measures of spending for people with serious illness and (2) linking spending and quality measures and rewarding performance for the care of people with serious illness. We limited our search to U.S.-based studies published in English between January 1, 1960, and March 31, 2017. We supplemented this search by identifying public programs and other known initiatives that linked quality and spending for the seriously ill and extracted key program elements. Our search related to linking spending and quality measures and rewarding performance for the care of people with serious illness yielded 277 articles. We identified three current public programs that currently link measures of quality and spending-or are likely to within the next few years-the Oncology Care Model; the Comprehensive End-Stage Renal Disease Model; and Home Health Value-Based Purchasing. Models that link quality and spending consist of four core components: (1) measuring quality, (2) measuring spending, (3) the payment adjustment model, and (4) the linking/incentive model. We found that current efforts to reward value for seriously ill patients are targeted for specific patient populations, do not broadly encourage the use of palliative care, and have not closely aligned quality and spending measures related to palliative care. We develop recommendations for policymakers and stakeholders about how measures of spending and quality can be balanced in value-based payment programs.

  12. Linking Quality and Spending to Measure Value for People with Serious Illness

    PubMed Central

    Rodgers, Phillip E.

    2018-01-01

    Abstract Background: Healthcare payment is rapidly evolving to reward value by measuring and paying for quality and spending performance. Rewarding value for the care of seriously ill patients presents unique challenges. Objective: To evaluate the state of current efforts to measure and reward value for the care of seriously ill patients. Design: We performed a PubMed search of articles related to (1) measures of spending for people with serious illness and (2) linking spending and quality measures and rewarding performance for the care of people with serious illness. We limited our search to U.S.-based studies published in English between January 1, 1960, and March 31, 2017. We supplemented this search by identifying public programs and other known initiatives that linked quality and spending for the seriously ill and extracted key program elements. Results: Our search related to linking spending and quality measures and rewarding performance for the care of people with serious illness yielded 277 articles. We identified three current public programs that currently link measures of quality and spending—or are likely to within the next few years—the Oncology Care Model; the Comprehensive End-Stage Renal Disease Model; and Home Health Value-Based Purchasing. Models that link quality and spending consist of four core components: (1) measuring quality, (2) measuring spending, (3) the payment adjustment model, and (4) the linking/incentive model. We found that current efforts to reward value for seriously ill patients are targeted for specific patient populations, do not broadly encourage the use of palliative care, and have not closely aligned quality and spending measures related to palliative care. Conclusions: We develop recommendations for policymakers and stakeholders about how measures of spending and quality can be balanced in value-based payment programs. PMID:29091529

  13. An automated A-value measurement tool for accurate cochlear duct length estimation.

    PubMed

    Iyaniwura, John E; Elfarnawany, Mai; Ladak, Hanif M; Agrawal, Sumit K

    2018-01-22

    There has been renewed interest in the cochlear duct length (CDL) for preoperative cochlear implant electrode selection and postoperative generation of patient-specific frequency maps. The CDL can be estimated by measuring the A-value, which is defined as the length between the round window and the furthest point on the basal turn. Unfortunately, there is significant intra- and inter-observer variability when these measurements are made clinically. The objective of this study was to develop an automated A-value measurement algorithm to improve accuracy and eliminate observer variability. Clinical and micro-CT images of 20 cadaveric cochleae specimens were acquired. The micro-CT of one sample was chosen as the atlas, and A-value fiducials were placed onto that image. Image registration (rigid affine and non-rigid B-spline) was applied between the atlas and the 19 remaining clinical CT images. The registration transform was applied to the A-value fiducials, and the A-value was then automatically calculated for each specimen. High resolution micro-CT images of the same 19 specimens were used to measure the gold standard A-values for comparison against the manual and automated methods. The registration algorithm had excellent qualitative overlap between the atlas and target images. The automated method eliminated the observer variability and the systematic underestimation by experts. Manual measurement of the A-value on clinical CT had a mean error of 9.5 ± 4.3% compared to micro-CT, and this improved to an error of 2.7 ± 2.1% using the automated algorithm. Both the automated and manual methods correlated significantly with the gold standard micro-CT A-values (r = 0.70, p < 0.01 and r = 0.69, p < 0.01, respectively). An automated A-value measurement tool using atlas-based registration methods was successfully developed and validated. The automated method eliminated the observer variability and improved accuracy as compared to manual

  14. The Role of Patient-Reported Outcome Measures in Value-Based Payment Reform.

    PubMed

    Squitieri, Lee; Bozic, Kevin J; Pusic, Andrea L

    2017-06-01

    The U.S. health care system is currently experiencing profound change. Pressure to improve the quality of patient care and control costs have caused a rapid shift from traditional volume-driven fee-for-service reimbursement to value-based payment models. Under the 2015 Medicare Access and Children's Health Insurance Program Reauthorization Act, providers will be evaluated on the basis of quality and cost efficiency and ultimately receive adjusted reimbursement as per their performance. Although current performance metrics do not incorporate patient-reported outcome measures (PROMs), many wonder whether and how PROMs will eventually fit into value-based payment reform. On November 17, 2016, the second annual Patient-Reported Outcomes in Healthcare Conference brought together international stakeholders across all health care disciplines to discuss the potential role of PROs in value-based health care reform. The purpose of this article was to summarize the findings from this conference in the context of recent literature and guidelines to inform implementation of PROs in value-based payment models. Recommendations for evaluating key perspectives and measurement goals are made to facilitate appropriate use of PROMs to best benefit and amplify the voice of our patients. Copyright © 2017 International Society for Pharmacoeconomics and Outcomes Research (ISPOR). Published by Elsevier Inc. All rights reserved.

  15. How to Use Value-Added Measures Right

    ERIC Educational Resources Information Center

    Di Carlo, Matthew

    2012-01-01

    Value-added models are a specific type of "growth model," a diverse group of statistical techniques to isolate a teacher's impact on his or her students' testing progress while controlling for other measurable factors, such as student and school characteristics, that are outside that teacher's control. Opponents, including many teachers, argue…

  16. What's the Difference? A Model for Measuring the Value Added by Higher Education in Australia

    ERIC Educational Resources Information Center

    Coates, Hamish

    2009-01-01

    Measures of student learning are playing an increasingly significant role in determining the quality and productivity of higher education. This paper evaluates approaches for estimating the value added by university education, and proposes a methodology for use by institutions and systems. The paper argues that value-added measures of learning are…

  17. The vexing problem of defining the meaning, role and measurement of values in treatment decision-making.

    PubMed

    Charles, Cathy; Gafni, Amiram

    2014-03-01

    Two international movements, evidence-based medicine (EBM) and shared decision-making (SDM) have grappled for some time with issues related to defining the meaning, role and measurement of values/preferences in their respective models of treatment decision-making. In this article, we identify and describe unresolved problems in the way that each movement addresses these issues. The starting point for this discussion is that at least two essential ingredients are needed for treatment decision-making: research information about treatment options and their potential benefits and risks; and the values/preferences of participants in the decision-making process. Both the EBM and SDM movements have encountered difficulties in defining the meaning, role and measurement of values/preferences in treatment decision-making. In the EBM model of practice, there is no clear and consistent definition of patient values/preferences and no guidance is provided on how to integrate these into an EBM model of practice. Methods advocated to measure patient values are also problematic. Within the SDM movement, patient values/preferences tend to be defined and measured in a restrictive and reductionist way as patient preferences for treatment options or attributes of options, while broader underlying value structures are ignored. In both models of practice, the meaning and expected role of physician values in decision-making are unclear. Values clarification exercises embedded in patient decision aids are suggested by SDM advocates to identify and communicate patient values/preferences for different treatment outcomes. Such exercises have the potential to impose a particular decision-making theory and/or process onto patients, which can change the way they think about and process information, potentially impeding them from making decisions that are consistent with their true values. The tasks of clarifying the meaning, role and measurement of values/preferences in treatment decision

  18. Repeatability, variability and reference values of pulsed wave Doppler echocardiographic measurements in healthy Saanen goats

    PubMed Central

    2012-01-01

    Background Pulsed wave (PW) Doppler echocardiography has become a routine non invasive cardiac diagnostic tool in most species. However, evaluation of intracardiac blood flow requires reference values, which are poorly documented in goats. The aim of this study was to test the repeatability, the variability, and to establish the reference values of PW measurements in healthy adult Saanen goats. Using a standardised PW Doppler echocardiographic protocol, 10 healthy adult unsedated female Saanen goats were investigated three times at one day intervals by the same observer. Mitral, tricuspid, aortic and pulmonary flows were measured from a right parasternal view, and mitral and aortic flows were also measured from a left parasternal view. The difference between left and right side measurements and the intra-observer inter-day repeatability were tested and then the reference values of PW Doppler echocardiographic parameters in healthy adult female Saanen goats were established. Results As documented in other species, all caprine PW Doppler parameters demonstrated a poor inter-day repeatability and a moderate variability. Tricuspid and pulmonary flows were best evaluated on the right side whereas mitral and aortic flows were best obtained on the left side, and reference values are reported for healthy adult Saanen goats. Conclusions PW Doppler echocardiography allows the measurement of intracardiac blood flow indices in goats. The reference values establishment will help interpreting these indices of cardiac function in clinical cardiac cases and developing animal models for human cardiology research. PMID:23067875

  19. Value-Added Measures in Education: What Every Educator Needs to Know

    ERIC Educational Resources Information Center

    Harris, Douglas N.

    2011-01-01

    In "Value-Added Measures in Education", Douglas N. Harris takes on one of the most hotly debated topics in education. Drawing on his extensive work with schools and districts, he sets out to help educators and policymakers understand this innovative approach to assessment and the issues associated with its use. Written in straightforward language…

  20. Accuracy of apparent diffusion coefficient value measurement on PACS workstation: A comparative analysis.

    PubMed

    El Kady, Reem M; Choudhary, Arabinda Kumar; Tappouni, Rafel

    2011-03-01

    The purpose of this article is to evaluate the accuracy of apparent diffusion coefficient (ADC) measurements made with a PACS workstation compared with measurements made with a dedicated workstation, which is currently considered the reference standard. A retrospective review was performed in liver lesions from 79 patients using three MRI platforms. The final diagnosis was established by liver biopsy in 31 patients and by dynamic MRI and follow-up, both clinical and radiologic as indicated, in 48 patients. Each lesion that was clearly demonstrable on the ADC map was measured with a commercial dedicated postprocessing workstation and again with a PACS system. A two-sample t test was used to determine the statistically significant differences between the two ADC measurements. A total of 79 patients with 120 liver lesions were included. ADC values measured on the workstation were 0.4-4.38 × 10(-3) mm(2)/s. The ADC values measured on the PACS were 0.42-4.35 × 10(-3) mm(2)/s. The T value was -1.113, with 119 degrees of freedom, and the significance level was 0.268, which implies no significant difference between the two different measuring systems for all pathologic abnormalities and MRI scanners used. ADC values measured on a routine PACS workstation are as accurate as the values obtained on a dedicated specialized workstation. ADC value measurement on the routine PACS will save time and lead to increased utilization, which, in turn, will lead to an improved understanding of the different disease processes and their clinical management.

  1. Measuring Nursing Value from the Electronic Health Record.

    PubMed

    Welton, John M; Harper, Ellen M

    2016-01-01

    We report the findings of a big data nursing value expert group made up of 14 members of the nursing informatics, leadership, academic and research communities within the United States tasked with 1. Defining nursing value, 2. Developing a common data model and metrics for nursing care value, and 3. Developing nursing business intelligence tools using the nursing value data set. This work is a component of the Big Data and Nursing Knowledge Development conference series sponsored by the University Of Minnesota School Of Nursing. The panel met by conference calls for fourteen 1.5 hour sessions for a total of 21 total hours of interaction from August 2014 through May 2015. Primary deliverables from the bit data expert group were: development and publication of definitions and metrics for nursing value; construction of a common data model to extract key data from electronic health records; and measures of nursing costs and finance to provide a basis for developing nursing business intelligence and analysis systems.

  2. What's the Value in Value-Added?

    ERIC Educational Resources Information Center

    Duffrin, Elizabeth

    2011-01-01

    A growing number of school districts are adopting "value-added" measures of teaching quality to award bonuses or even tenure. And two competitive federal grants are spurring them on. Districts using value-added data are encouraged by the results. But researchers who support value-added measures advise caution. The ratings, which use a…

  3. Patient value: its nature, measurement, and role in real world evidence studies and outcomes-based reimbursement.

    PubMed

    McKenna, Stephen P; Wilburn, Jeanette

    2018-05-01

    The assessment of "patient value" is fundamental to clinical trials, real world evidence studies, and outcomes-based reimbursement schemes. Measures of health-related quality-of-life (HRQoL) are widely used in health research. Such measures are effective in determining the presence or absence of symptoms and functional ability. However, HRQoL measures were not intended, nor designed, to determine the value to patients of alternative health states. Functions have no intrinsic value-they are a means to fulfil human needs. However, needs can be met in a variety of ways, for example by adopting different functions or by the provision of social services. It is possible to analyze all functions in terms of the needs they satisfy. A needs model has been applied in health research since the 1990s. It is concerned with the extent to which human needs are fulfilled in the presence of disease and its treatment. It is argued that this is the major concern of the patient. Needs-based measures are patient-centric and produce a valid unidimensional index of outcome. Consequently, they provide a direct means of measuring patient value. This approach provides the possibility of evaluating health services in terms of the value they provide to consumers and payers. It also has a role to play in real-world evidence studies and outcomes-based reimbursement. It is recommended that greater attention is given in future to the development of patient-reported outcome measures that provide direct assessments of patient value.

  4. Measuring the Value of Placements to Employers: A Cost-Benefit Approach

    ERIC Educational Resources Information Center

    Wond, Tracey; Rambukwella, Shan

    2018-01-01

    This article explores the concept and measurement of placement value, underexplored in theory and practice to date. The article makes a theoretical contribution to the placement value discourse by examining and articulating the placement value concept. It also offers a practical contribution by exploring a piloted tool to evaluate employer…

  5. Reference Values for Body Composition and Anthropometric Measurements in Athletes

    PubMed Central

    Santos, Diana A.; Dawson, John A.; Matias, Catarina N.; Rocha, Paulo M.; Minderico, Cláudia S.; Allison, David B.; Sardinha, Luís B.; Silva, Analiza M.

    2014-01-01

    Background Despite the importance of body composition in athletes, reference sex- and sport-specific body composition data are lacking. We aim to develop reference values for body composition and anthropometric measurements in athletes. Methods Body weight and height were measured in 898 athletes (264 female, 634 male), anthropometric variables were assessed in 798 athletes (240 female and 558 male), and in 481 athletes (142 female and 339 male) with dual-energy X-ray absorptiometry (DXA). A total of 21 different sports were represented. Reference percentiles (5th, 25th, 50th, 75th, and 95th) were calculated for each measured value, stratified by sex and sport. Because sample sizes within a sport were often very low for some outcomes, the percentiles were estimated using a parametric, empirical Bayesian framework that allowed sharing information across sports. Results We derived sex- and sport-specific reference percentiles for the following DXA outcomes: total (whole body scan) and regional (subtotal, trunk, and appendicular) bone mineral content, bone mineral density, absolute and percentage fat mass, fat-free mass, and lean soft tissue. Additionally, we derived reference percentiles for height-normalized indexes by dividing fat mass, fat-free mass, and appendicular lean soft tissue by height squared. We also derived sex- and sport-specific reference percentiles for the following anthropometry outcomes: weight, height, body mass index, sum of skinfold thicknesses (7 skinfolds, appendicular skinfolds, trunk skinfolds, arm skinfolds, and leg skinfolds), circumferences (hip, arm, midthigh, calf, and abdominal circumferences), and muscle circumferences (arm, thigh, and calf muscle circumferences). Conclusions These reference percentiles will be a helpful tool for sports professionals, in both clinical and field settings, for body composition assessment in athletes. PMID:24830292

  6. Anorectal physiology measurements are of no value in clinical practice. True or false?

    PubMed Central

    Carty, N. J.; Moran, B.; Johnson, C. D.

    1994-01-01

    This article examines whether there is any clinical value in anorectal physiology measurements. The function of the human rectum is poorly understood and the factors which affect function of the anal sphincters are complex. Several laboratories have reported results of anorectal physiology measurements, but there is extensive variation between normal values in different laboratories. It is argued that anorectal physiology measurements fail to meet the criteria of a useful clinical test: 1. It is not widely available to clinicians; 2. It is not possible to establish a reproducible normal range; 3. Abnormal measurements do not correlate with disease entities or explain symptoms; 4. The results are often unhelpful in diagnosis and management; 5. Clinical outcome after intervention does not correlate with alteration in the measurements obtained. On the other hand it can be argued that anorectal physiology measurements do provide information that assists in the management of conditions such as constipation, anismus, Hirschsprung's disease, faecal incontinence and tenesmus. Management based on biofeedback modification of physiological responses requires these techniques as part of the biofeedback system. There is evidence that this may be appropriate in anismus and solitary rectal ulcer syndrome. However, the assessment of these difficult conditions and the interpretation of the results are probably at present best confined to specialist units. PMID:8074392

  7. Clustering of reads with alignment-free measures and quality values.

    PubMed

    Comin, Matteo; Leoni, Andrea; Schimd, Michele

    2015-01-01

    The data volume generated by Next-Generation Sequencing (NGS) technologies is growing at a pace that is now challenging the storage and data processing capacities of modern computer systems. In this context an important aspect is the reduction of data complexity by collapsing redundant reads in a single cluster to improve the run time, memory requirements, and quality of post-processing steps like assembly and error correction. Several alignment-free measures, based on k-mers counts, have been used to cluster reads. Quality scores produced by NGS platforms are fundamental for various analysis of NGS data like reads mapping and error detection. Moreover future-generation sequencing platforms will produce long reads but with a large number of erroneous bases (up to 15 %). In this scenario it will be fundamental to exploit quality value information within the alignment-free framework. To the best of our knowledge this is the first study that incorporates quality value information and k-mers counts, in the context of alignment-free measures, for the comparison of reads data. Based on this principles, in this paper we present a family of alignment-free measures called D (q) -type. A set of experiments on simulated and real reads data confirms that the new measures are superior to other classical alignment-free statistics, especially when erroneous reads are considered. Also results on de novo assembly and metagenomic reads classification show that the introduction of quality values improves over standard alignment-free measures. These statistics are implemented in a software called QCluster (http://www.dei.unipd.it/~ciompin/main/qcluster.html).

  8. New measurements of W-values for protons and alpha particles.

    PubMed

    Giesen, U; Beck, J

    2014-10-01

    The increasing importance of ion beams in cancer therapy and the lack of experimental data for W-values for protons and heavy ions in air require new measurements. A new experimental set-up was developed at PTB and consistent measurements of W-values in argon, nitrogen and air for protons and alpha particles with energies from 0.7 to 3.5 MeV u(-1) at PTB, and for carbon ions between 3.6 and 7.0 MeV u(-1) at GSI were carried out. This publication concentrates on the measurements with protons and alpha particles at PTB. The experimental methods and the determination of corrections for recombination effects, beam-induced background radiation and additional effects are presented. © The Author 2013. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.

  9. Reverse engineering gene regulatory networks from measurement with missing values.

    PubMed

    Ogundijo, Oyetunji E; Elmas, Abdulkadir; Wang, Xiaodong

    2016-12-01

    Gene expression time series data are usually in the form of high-dimensional arrays. Unfortunately, the data may sometimes contain missing values: for either the expression values of some genes at some time points or the entire expression values of a single time point or some sets of consecutive time points. This significantly affects the performance of many algorithms for gene expression analysis that take as an input, the complete matrix of gene expression measurement. For instance, previous works have shown that gene regulatory interactions can be estimated from the complete matrix of gene expression measurement. Yet, till date, few algorithms have been proposed for the inference of gene regulatory network from gene expression data with missing values. We describe a nonlinear dynamic stochastic model for the evolution of gene expression. The model captures the structural, dynamical, and the nonlinear natures of the underlying biomolecular systems. We present point-based Gaussian approximation (PBGA) filters for joint state and parameter estimation of the system with one-step or two-step missing measurements . The PBGA filters use Gaussian approximation and various quadrature rules, such as the unscented transform (UT), the third-degree cubature rule and the central difference rule for computing the related posteriors. The proposed algorithm is evaluated with satisfying results for synthetic networks, in silico networks released as a part of the DREAM project, and the real biological network, the in vivo reverse engineering and modeling assessment (IRMA) network of yeast Saccharomyces cerevisiae . PBGA filters are proposed to elucidate the underlying gene regulatory network (GRN) from time series gene expression data that contain missing values. In our state-space model, we proposed a measurement model that incorporates the effect of the missing data points into the sequential algorithm. This approach produces a better inference of the model parameters and hence

  10. Reference value sensitivity of measures of unfair health inequality

    PubMed Central

    García-Gómez, Pilar; Schokkaert, Erik; Van Ourti, Tom

    2014-01-01

    Most politicians and ethical observers are not interested in pure health inequalities, as they want to distinguish between different causes of health differences. Measures of “unfair” inequality - direct unfairness and the fairness gap, but also the popular standardized concentration index - therefore neutralize the effects of what are considered to be “legitimate” causes of inequality. This neutralization is performed by putting a subset of the explanatory variables at reference values, e.g. their means. We analyze how the inequality ranking of different policies depends on the specific choice of reference values. We show with mortality data from the Netherlands that the problem is empirically relevant and we suggest a statistical method for fixing the reference values. PMID:24954998

  11. Behavioral Economic Measures of Alcohol Reward Value as Problem Severity Indicators in College Students

    PubMed Central

    Skidmore, Jessica R.; Murphy, James G.; Martens, Matthew P.

    2014-01-01

    The aims of the current study were to examine the associations among behavioral economic measures of alcohol value derived from three distinct measurement approaches, and to evaluate their respective relations with traditional indicators of alcohol problem severity in college drinkers. Five behavioral economic metrics were derived from hypothetical demand curves that quantify reward value by plotting consumption and expenditures as a function of price, another metric measured proportional behavioral allocation and enjoyment related to alcohol versus other activities, and a final metric measured relative discretionary expenditures on alcohol. The sample included 207 heavy drinking college students (53% female) who were recruited through an on-campus health center or university courses. Factor analysis revealed that the alcohol valuation construct comprises two factors: one factor that reflects participants’ levels of alcohol price sensitivity (demand persistence), and a second factor that reflects participants’ maximum consumption and monetary and behavioral allocation towards alcohol (amplitude of demand). The demand persistence and behavioral allocation metrics demonstrated the strongest and most consistent multivariate relations with alcohol-related problems, even when controlling for other well-established predictors. The results suggest that behavioral economic indices of reward value show meaningful relations with alcohol problem severity in young adults. Despite the presence of some gender differences, these measures appear to be useful problem indicators for men and women. PMID:24749779

  12. Network analysis of surgical innovation: Measuring value and the virality of diffusion in robotic surgery.

    PubMed

    Garas, George; Cingolani, Isabella; Panzarasa, Pietro; Darzi, Ara; Athanasiou, Thanos

    2017-01-01

    Existing surgical innovation frameworks suffer from a unifying limitation, their qualitative nature. A rigorous approach to measuring surgical innovation is needed that extends beyond detecting simply publication, citation, and patent counts and instead uncovers an implementation-based value from the structure of the entire adoption cascades produced over time by diffusion processes. Based on the principles of evidence-based medicine and existing surgical regulatory frameworks, the surgical innovation funnel is described. This illustrates the different stages through which innovation in surgery typically progresses. The aim is to propose a novel and quantitative network-based framework that will permit modeling and visualizing innovation diffusion cascades in surgery and measuring virality and value of innovations. Network analysis of constructed citation networks of all articles concerned with robotic surgery (n = 13,240, Scopus®) was performed (1974-2014). The virality of each cascade was measured as was innovation value (measured by the innovation index) derived from the evidence-based stage occupied by the corresponding seed article in the surgical innovation funnel. The network-based surgical innovation metrics were also validated against real world big data (National Inpatient Sample-NIS®). Rankings of surgical innovation across specialties by cascade size and structural virality (structural depth and width) were found to correlate closely with the ranking by innovation value (Spearman's rank correlation coefficient = 0.758 (p = 0.01), 0.782 (p = 0.008), 0.624 (p = 0.05), respectively) which in turn matches the ranking based on real world big data from the NIS® (Spearman's coefficient = 0.673;p = 0.033). Network analysis offers unique new opportunities for understanding, modeling and measuring surgical innovation, and ultimately for assessing and comparing generative value between different specialties. The novel surgical innovation metrics developed may

  13. Blood glucose measurement in patients with suspected diabetic ketoacidosis: a comparison of Abbott MediSense PCx point-of-care meter values to reference laboratory values.

    PubMed

    Blank, Fidela S J; Miller, Moses; Nichols, James; Smithline, Howard; Crabb, Gillian; Pekow, Penelope

    2009-04-01

    The purpose of this study is to compare blood glucose levels measured by a point of care (POC) device to laboratory measurement using the same sample venous blood from patients with suspected diabetic ketoacidosis (DKA). A descriptive correlational design was used for this IRB-approved quality assurance project. The study site was the 50-bed BMC emergency department (ED) which has an annual census of over 100,000 patient visits. The convenience sample consisted of 54 blood samples from suspected DKA patients with orders for hourly blood draws for glucose measurement. Spearman correlations of the glucose POC values, reference lab values, and differences between the two, were evaluated. A chi-square test was used to evaluate the association between the acidosis status and FDA acceptability of POC values. Patient age range was 10-86 years; 63% were females; 46% had a final diagnosis of DKA. POC values underestimated glucose levels 93% of the time. There was a high correlation between the lab value and the magnitude of the difference, (lab minus POC value) indicating that the higher the true glucose value, the greater the difference between the lab and the POC value. A chi-square test showed no overall association between acidosis and FDA-acceptability. The POC values underestimated lab reported glucose levels in 50 of 54 cases even with the use of same venous sample sent to the lab, which make it highly unreliable for use in monitoring suspected DKA patients.

  14. Biases in Multicenter Longitudinal PET Standardized Uptake Value Measurements1

    PubMed Central

    Doot, Robert K; Pierce, Larry A; Byrd, Darrin; Elston, Brian; Allberg, Keith C; Kinahan, Paul E

    2014-01-01

    This study investigates measurement biases in longitudinal positron-emission tomography/computed tomography (PET/CT) studies that are due to instrumentation variability including human error. Improved estimation of variability between patient scans is of particular importance for assessing response to therapy and multicenter trials. We used National Institute of Standards and Technology-traceable calibration methodology for solid germanium-68/gallium-68 (68Ge/68Ga) sources used as surrogates for fluorine-18 (18F) in radionuclide activity calibrators. One cross-calibration kit was constructed for both dose calibrators and PET scanners using the same 9-month half-life batch of 68Ge/68Ga in epoxy. Repeat measurements occurred in a local network of PET imaging sites to assess standardized uptake value (SUV) errors over time for six dose calibrators from two major manufacturers and for six PET/CT scanners from three major manufacturers. Bias in activity measures by dose calibrators ranged from -50% to 9% and was relatively stable over time except at one site that modified settings between measurements. Bias in activity concentration measures by PET scanners ranged from -27% to 13% with a median of 174 days between the six repeat scans (range, 29 to 226 days). Corresponding errors in SUV measurements ranged from -20% to 47%. SUV biases were not stable over time with longitudinal differences for individual scanners ranging from -11% to 59%. Bias in SUV measurements varied over time and between scanner sites. These results suggest that attention should be paid to PET scanner calibration for longitudinal studies and use of dose calibrator and scanner cross-calibration kits could be helpful for quality assurance and control. PMID:24772207

  15. Property Values as a Measure of Neighborhoods: An Application of Hedonic Price Theory.

    PubMed

    Leonard, Tammy; Powell-Wiley, Tiffany M; Ayers, Colby; Murdoch, James C; Yin, Wenyuan; Pruitt, Sandi L

    2016-07-01

    Researchers measuring relationships between neighborhoods and health have begun using property appraisal data as a source of information about neighborhoods. Economists have developed a rich tool kit to understand how neighborhood characteristics are quantified in appraisal values. This tool kit principally relies on hedonic (implicit) price models and has much to offer regarding the interpretation and operationalization of property appraisal data-derived neighborhood measures, which goes beyond the use of appraisal data as a measure of neighborhood socioeconomic status. We develop a theoretically informed hedonic-based neighborhood measure using residuals of a hedonic price regression applied to appraisal data in a single metropolitan area. We describe its characteristics, reliability in different types of neighborhoods, and correlation with other neighborhood measures (i.e., raw neighborhood appraisal values, census block group poverty, and observed property characteristics). We examine the association between all neighborhood measures and body mass index. The hedonic-based neighborhood measure was correlated in the expected direction with block group poverty rate and observed property characteristics. The neighborhood measure and average raw neighborhood appraisal value, but not census block group poverty, were associated with individual body mass index. We draw theoretically consistent methodology from the economics literature on hedonic price models to demonstrate how to leverage the implicit valuation of neighborhoods contained in publicly available appraisal data. Consistent measurement and application of the hedonic-based neighborhood measures in epidemiology will improve understanding of the relationships between neighborhoods and health. Researchers should proceed with a careful use of appraisal values utilizing theoretically informed methods such as this one.

  16. The incremental value of self-reported mental health measures in predicting functional outcomes of veterans.

    PubMed

    Eisen, Susan V; Bottonari, Kathryn A; Glickman, Mark E; Spiro, Avron; Schultz, Mark R; Herz, Lawrence; Rosenheck, Robert; Rofman, Ethan S

    2011-04-01

    Research on patient-centered care supports use of patient/consumer self-report measures in monitoring health outcomes. This study examined the incremental value of self-report mental health measures relative to a clinician-rated measure in predicting functional outcomes among mental health service recipients. Participants (n = 446) completed the Behavior and Symptom Identification Scale, the Brief Symptom Inventory, and the Veterans/Rand Short Form-36 at enrollment in the study (T1) and 3 months later (T2). Global Assessment of Functioning (GAF) ratings, mental health service utilization, and psychiatric diagnoses were obtained from administrative data files. Controlling for demographic and clinical variables, results indicated that improvement based on the self-report measures significantly predicted one or more functional outcomes (i.e., decreased likelihood of post-enrollment psychiatric hospitalization and increased likelihood of paid employment), above and beyond the predictive value of the GAF. Inclusion of self-report measures may be a useful addition to performance measurement efforts.

  17. Weak values and weak coupling maximizing the output of weak measurements

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Di Lorenzo, Antonio, E-mail: dilorenzo.antonio@gmail.com

    2014-06-15

    In a weak measurement, the average output 〈o〉 of a probe that measures an observable A{sup -hat} of a quantum system undergoing both a preparation in a state ρ{sub i} and a postselection in a state E{sub f} is, to a good approximation, a function of the weak value A{sub w}=Tr[E{sub f}A{sup -hat} ρ{sub i}]/Tr[E{sub f}ρ{sub i}], a complex number. For a fixed coupling λ, when the overlap Tr[E{sub f}ρ{sub i}] is very small, A{sub w} diverges, but 〈o〉 stays finite, often tending to zero for symmetry reasons. This paper answers the questions: what is the weak value that maximizesmore » the output for a fixed coupling? What is the coupling that maximizes the output for a fixed weak value? We derive equations for the optimal values of A{sub w} and λ, and provide the solutions. The results are independent of the dimensionality of the system, and they apply to a probe having a Hilbert space of arbitrary dimension. Using the Schrödinger–Robertson uncertainty relation, we demonstrate that, in an important case, the amplification 〈o〉 cannot exceed the initial uncertainty σ{sub o} in the observable o{sup -hat}, we provide an upper limit for the more general case, and a strategy to obtain 〈o〉≫σ{sub o}. - Highlights: •We have provided a general framework to find the extremal values of a weak measurement. •We have derived the location of the extremal values in terms of preparation and postselection. •We have devised a maximization strategy going beyond the limit of the Schrödinger–Robertson relation.« less

  18. Valuing Informal Care Experience: Does Choice of Measure Matter?

    ERIC Educational Resources Information Center

    Mentzakis, Emmanouil; McNamee, Paul; Ryan, Mandy; Sutton, Matthew

    2012-01-01

    Well-being equations are often estimated to generate monetary values for non-marketed activities. In such studies, utility is often approximated by either life satisfaction or General Health Questionnaire scores. We estimate and compare monetary valuations of informal care for the first time in the UK employing both measures, using longitudinal…

  19. Measuring and Communicating the Value Created by an Organization

    ERIC Educational Resources Information Center

    Sherman, W. Richard

    2010-01-01

    This paper offers a different perspective in measuring the value created by an organization. It does so in the context of an undergraduate course in managerial accounting. In order to break down the functional silo approach to problem solving that has become the model of traditional business education, applications of shadow accounting, the…

  20. Comparison of oxygen saturation values and measurement times by pulse oximetry in various parts of the body.

    PubMed

    Yönt, Gülendam Hakverdioğlu; Korhan, Esra Akin; Khorshid, Leyla

    2011-11-01

    The aim of this study, which included 40 patients, was to compare the values pulse oximetry and the measurement times in various regions of the body. Data were analyzed using intraclass correlation coefficient test and paired-sample test. The confidence power value was found to be .81 for the comparison of oxygen saturation values by arterial blood gas analysis and measurement by the forehead probe. It was found that the time for oxygen saturation measurement using the forehead probe was shorter than those using the finger and toe probes. Copyright © 2011 Elsevier Inc. All rights reserved.

  1. Measuring the nose in septorhinoplasty patients: ultrasonographic standard values and clinical correlations.

    PubMed

    Stenner, Markus; Koopmann, Mario; Rudack, Claudia

    2017-02-01

    Although septorhinoplasty is the most commonly performed operation in plastic surgery, and the surgical plan as well as its outcome is directly related to the configuration of the anatomical structures in the nose, these are not routinely assessed preoperatively. The aim of our study was to evaluate the nasal soft tissue and cartilaginous structures by means of high-resolution ultrasonography to set up clinical correlations and standard values. We examined 44 patients before septorhinoplasty by high-resolution ultrasonography in noncontact mode. All pictures were quantitatively evaluated by measuring 13 lengths and 4 ratios. All patients underwent a rhinomanometry measuring the nasal air flow. Besides others, men as well as older patients have a significantly thicker alar cartilage. Patients with thinner alar cartilages have a significantly smaller interdomal distance as well as significantly thinner upper lateral cartilages. The soft tissue above the bony dorsum was significantly thicker in older patients. Younger patients have significantly thicker soft tissue in relation to their cartilage. Patients with thicker soft tissue and thinner cartilage have a smaller tip. The interdomal distance and the thickness of the cartilaginous septum significantly correlated with the nasal air flow. We set up standard values of nasal structures in septorhinoplasty patients which can be used as reference values. By judging cartilage and soft tissue characteristics preoperatively, relevant factors for distinct procedures could be analyzed and the surgical steps can be better planned. Visualization by ultrasonography enables the surgeon to achieve treatment goals in a more predictable fashion.

  2. A scheme of quantum state discrimination over specified states via weak-value measurement

    NASA Astrophysics Data System (ADS)

    Chen, Xi; Dai, Hong-Yi; Liu, Bo-Yang; Zhang, Ming

    2018-04-01

    The commonly adopted projective measurements are invalid in the specified task of quantum state discrimination when the discriminated states are superposition of planar-position basis states whose complex-number probability amplitudes have the same magnitude but different phases. Therefore we propose a corresponding scheme via weak-value measurement and examine the feasibility of this scheme. Furthermore, the role of the weak-value measurement in quantum state discrimination is analyzed and compared with one in quantum state tomography in this Letter.

  3. How Can Value-Added Measures Be Used for Teacher Improvement? What We Know Series: Value-Added Methods and Applications. Knowledge Brief 13

    ERIC Educational Resources Information Center

    Loeb, Susanna

    2013-01-01

    The question for this brief is whether education leaders can use value-added measures as tools for improving schooling and, if so, how to do this. Districts, states, and schools can, at least in theory, generate gains in educational outcomes for students using value-added measures in three ways: creating information on effective programs, making…

  4. Network analysis of surgical innovation: Measuring value and the virality of diffusion in robotic surgery

    PubMed Central

    Cingolani, Isabella; Panzarasa, Pietro; Darzi, Ara; Athanasiou, Thanos

    2017-01-01

    Background Existing surgical innovation frameworks suffer from a unifying limitation, their qualitative nature. A rigorous approach to measuring surgical innovation is needed that extends beyond detecting simply publication, citation, and patent counts and instead uncovers an implementation-based value from the structure of the entire adoption cascades produced over time by diffusion processes. Based on the principles of evidence-based medicine and existing surgical regulatory frameworks, the surgical innovation funnel is described. This illustrates the different stages through which innovation in surgery typically progresses. The aim is to propose a novel and quantitative network-based framework that will permit modeling and visualizing innovation diffusion cascades in surgery and measuring virality and value of innovations. Materials and methods Network analysis of constructed citation networks of all articles concerned with robotic surgery (n = 13,240, Scopus®) was performed (1974–2014). The virality of each cascade was measured as was innovation value (measured by the innovation index) derived from the evidence-based stage occupied by the corresponding seed article in the surgical innovation funnel. The network-based surgical innovation metrics were also validated against real world big data (National Inpatient Sample–NIS®). Results Rankings of surgical innovation across specialties by cascade size and structural virality (structural depth and width) were found to correlate closely with the ranking by innovation value (Spearman’s rank correlation coefficient = 0.758 (p = 0.01), 0.782 (p = 0.008), 0.624 (p = 0.05), respectively) which in turn matches the ranking based on real world big data from the NIS® (Spearman’s coefficient = 0.673;p = 0.033). Conclusion Network analysis offers unique new opportunities for understanding, modeling and measuring surgical innovation, and ultimately for assessing and comparing generative value between different

  5. Calculating Measurement Uncertainty of the “Conventional Value of the Result of Weighing in Air”

    DOE PAGES

    Flicker, Celia J.; Tran, Hy D.

    2016-04-02

    The conventional value of the result of weighing in air is frequently used in commercial calibrations of balances. The guidance in OIML D-028 for reporting uncertainty of the conventional value is too terse. When calibrating mass standards at low measurement uncertainties, it is necessary to perform a buoyancy correction before reporting the result. When calculating the conventional result after calibrating true mass, the uncertainty due to calculating the conventional result is correlated with the buoyancy correction. We show through Monte Carlo simulations that the measurement uncertainty of the conventional result is less than the measurement uncertainty when reporting true mass.more » The Monte Carlo simulation tool is available in the online version of this article.« less

  6. Measuring the value of groundwater and other forms of natural capital.

    PubMed

    Fenichel, Eli P; Abbott, Joshua K; Bayham, Jude; Boone, Whitney; Haacker, Erin M K; Pfeiffer, Lisa

    2016-03-01

    Valuing natural capital is fundamental to measuring sustainability. The United Nations Environment Programme, World Bank, and other agencies have called for inclusion of the value of natural capital in sustainability metrics, such as inclusive wealth. Much has been written about the importance of natural capital, but consistent, rigorous valuation approaches compatible with the pricing of traditional forms of capital have remained elusive. We present a guiding quantitative framework enabling natural capital valuation that is fully consistent with capital theory, accounts for biophysical and economic feedbacks, and can guide interdisciplinary efforts to measure sustainability. We illustrate this framework with an application to groundwater in the Kansas High Plains Aquifer, a rapidly depleting asset supporting significant food production. We develop a 10-y time series (1996-2005) of natural capital asset prices that accounts for technological, institutional, and physical changes. Kansas lost approximately $110 million per year (2005 US dollars) of capital value through groundwater withdrawal and changes in aquifer management during the decade spanning 1996-2005. This annual loss in wealth is approximately equal to the state's 2005 budget surplus, and is substantially more than investments in schools over this period. Furthermore, real investment in agricultural capital also declined over this period. Although Kansas' depletion of water wealth is substantial, it may be tractably managed through careful groundwater management and compensating investments in other natural and traditional assets. Measurement of natural capital value is required to inform management and ongoing investments in natural assets.

  7. Negative measurement sensitivity values of planar capacitive imaging probes

    NASA Astrophysics Data System (ADS)

    Yin, Xiaokang; Chen, Guoming; Li, Wei; Hutchins, David

    2014-02-01

    The measurement sensitivity distribution of planar capacitive imaging (CI) probes describes how effectively each region in the sensing area is contributing to the measured charge signal on the sensing electrode. It can be used to determine the imaging ability of a CI probe. It is found in previous work that, there are regions in the sensing area where the change of the charge output and the change of targeting physical parameter are of opposite trends. This opposite correlation implies that the measurement sensitivity values in such regions are negative. In this work, the cause of negative sensitivity is discussed. Experiments are also designed and performed so as to verify the existence of negative sensitivity and study the factors that may affect the negative sensitivity distributions.

  8. The Math–Biology Values Instrument: Development of a Tool to Measure Life Science Majors’ Task Values of Using Math in the Context of Biology

    PubMed Central

    Andrews, Sarah E.; Runyon, Christopher; Aikens, Melissa L.

    2017-01-01

    In response to calls to improve the quantitative training of undergraduate biology students, there have been increased efforts to better integrate math into biology curricula. One challenge of such efforts is negative student attitudes toward math, which are thought to be particularly prevalent among biology students. According to theory, students’ personal values toward using math in a biological context will influence their achievement and behavioral outcomes, but a validated instrument is needed to determine this empirically. We developed the Math–Biology Values Instrument (MBVI), an 11-item college-level self-­report instrument grounded in expectancy-value theory, to measure life science students’ interest in using math to understand biology, the perceived usefulness of math to their life science career, and the cost of using math in biology courses. We used a process that integrates multiple forms of validity evidence to show that scores from the MBVI can be used as a valid measure of a student’s value of math in the context of biology. The MBVI can be used by instructors and researchers to help identify instructional strategies that influence math–biology values and understand how math–biology values are related to students’ achievement and decisions to pursue more advanced quantitative-based courses. PMID:28747355

  9. SU-E-I-19: CTDI Values for All Protocols: Using the Ratio of the DLP Measured in CTDI Phantoms to the Measured Air Exposure

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Raterman, G; Gauntt, D

    2014-06-01

    Purpose: To propose a method other than CTDI phantom measurements for routine CT dosimetry QA. This consists of taking a series of air exposure measurements and calculating a factor for converting from this exposure measurement to the protocol's associated head or body CTDI value using DLP. The data presented are the ratios of phantom DLP to air exposure ratios for different scanners, as well as error in the displayed CTDI. Methods: For each scanner, the CTDI is measured at all available tube voltages using both the head and body phantoms. Then, the exposure is measured using a pencil chamber inmore » air at isocenter. A ratio of phantom DLP to exposure in air for a given protocol may be calculated and used for converting a simple air dose measurement to a head or body CTDI value. For our routine QA, the exposure in air for different collimations, mAs, and kVp is measured, and displayed CTDI is recorded. Therefore, the ratio calculated may convert these exposures to CTDI values that may then be compared to the displayed CTDI for a large range of acquisition parameter combinations. Results: It was found that all scanners tend to have a ratio factor that slightly increases with kVp. Also, Philips scanners appear to have less of a dependence on kVp; whereas, GE scanners have a lower ratio at lower kVp. The use of air exposure times the DLP conversion yielded CTDI values that were less than 10% different from the displayed CTDI on several scanners. Conclusion: This method may be used as a primary method for CT dosimetry QA. As a result of the ease of measurement, a dosimetry metric specific to that scanner may be calculated for a wide variety of CT protocols, which could also be used to monitor display CTDI value accuracy.« less

  10. Workshop: Using Contingent Valuation to Measure Non-Market Values (1994)

    EPA Pesticide Factsheets

    Workshop co-hosted by USEPA and Dept of Energy on using contingent valuation to measure non-market values for improvement in health and the environment. Includes transcripts of presentations and discussion by attendees, later published as a book.

  11. A Method for Determining Pseudo-measurement State Values for Topology Observability of State Estimation in Power Systems

    NASA Astrophysics Data System (ADS)

    Urano, Shoichi; Mori, Hiroyuki

    This paper proposes a new technique for determining of state values in power systems. Recently, it is useful for carrying out state estimation with data of PMU (Phasor Measurement Unit). The authors have developed a method for determining state values with artificial neural network (ANN) considering topology observability in power systems. ANN has advantage to approximate nonlinear functions with high precision. The method evaluates pseudo-measurement state values of the data which are lost in power systems. The method is successfully applied to the IEEE 14-bus system.

  12. Measuring Value Added in Higher Education: A Proposed Methodology for Developing a Performance Indicator Based on the Economic Value Added to Graduates

    ERIC Educational Resources Information Center

    Rodgers, Timothy

    2007-01-01

    The 2003 UK higher education White Paper suggested that the sector needed to re-examine the potential of the value added concept. This paper describes a possible methodology for developing a performance indicator based on the economic value added to graduates. The paper examines how an entry-quality-adjusted measure of a graduate's…

  13. Interexaminer reliability in clinical measurement of L*C*h* values of anterior teeth using a spectrophotometer.

    PubMed

    Hassel, Alexander J; Grossmann, Anne-christiane; Schmitter, Marc; Balke, Zibandeh; Buzello, Anja M

    2007-01-01

    The objective of this study was to investigate interexaminer reliability in the clinical measurement of the L*C*h* (lightness/value, chroma, hue) values of anterior teeth using a spectrophotometer (Vita Easyshade). The basic color of the maxillary right central incisors and canines of 23 subjects was spectrophotometrically determined by 4 clinicians and an experienced user (development manager) of the spectrophotometer. Also, to analyze the effect of different training with the instrument on interexaminer reliability, 2 of the clinicians were instructed in the use of the spectrophotometer by the experienced examiner, whereas the others instructed themselves by studying the operating manual. Agreement between all examiners was acceptable to excellent (intraclass coefficient > 0.4). The mean value of the measured differences for the central incisors of all subjects for L* values was 5 (for C* = 3.8, h* = 2.7 degrees) and for canines, the mean L* was 4.5 (C* = 3, h* = 1.6 degrees). Results from comparison of the 2 different training methods were inconsistent. Agreement with the experienced examiner ranged from not acceptable (C* values for incisors of self-instructed examiners) to excellent. The distribution of the measurements of 1 subject could lead to deviations in color, probably with clinical impact. For canines, the measurements were at least equally reproducible (in some cases significantly more reproducible) compared to central incisors. Because of the small number of examiners and the inconsistent results, it was not possible to reach a definite conclusion about the effect of different training methods on interexaminer reliability.

  14. Extracting joint weak values with local, single-particle measurements.

    PubMed

    Resch, K J; Steinberg, A M

    2004-04-02

    Weak measurement is a new technique which allows one to describe the evolution of postselected quantum systems. It appears to be useful for resolving a variety of thorny quantum paradoxes, particularly when used to study properties of pairs of particles. Unfortunately, such nonlocal or joint observables often prove difficult to measure directly in practice (for instance, in optics-a common testing ground for this technique-strong photon-photon interactions would be needed to implement an appropriate von Neumann interaction). Here we derive a general, experimentally feasible, method for extracting these joint weak values from correlations between single-particle observables.

  15. Measuring the value of groundwater and other forms of natural capital

    PubMed Central

    Fenichel, Eli P.; Abbott, Joshua K.; Bayham, Jude; Boone, Whitney; Haacker, Erin M. K.; Pfeiffer, Lisa

    2016-01-01

    Valuing natural capital is fundamental to measuring sustainability. The United Nations Environment Programme, World Bank, and other agencies have called for inclusion of the value of natural capital in sustainability metrics, such as inclusive wealth. Much has been written about the importance of natural capital, but consistent, rigorous valuation approaches compatible with the pricing of traditional forms of capital have remained elusive. We present a guiding quantitative framework enabling natural capital valuation that is fully consistent with capital theory, accounts for biophysical and economic feedbacks, and can guide interdisciplinary efforts to measure sustainability. We illustrate this framework with an application to groundwater in the Kansas High Plains Aquifer, a rapidly depleting asset supporting significant food production. We develop a 10-y time series (1996−2005) of natural capital asset prices that accounts for technological, institutional, and physical changes. Kansas lost approximately $110 million per year (2005 US dollars) of capital value through groundwater withdrawal and changes in aquifer management during the decade spanning 1996–2005. This annual loss in wealth is approximately equal to the state’s 2005 budget surplus, and is substantially more than investments in schools over this period. Furthermore, real investment in agricultural capital also declined over this period. Although Kansas’ depletion of water wealth is substantial, it may be tractably managed through careful groundwater management and compensating investments in other natural and traditional assets. Measurement of natural capital value is required to inform management and ongoing investments in natural assets. PMID:26858431

  16. A Value Measure for Public-Sector Enterprise Risk Management: A TSA Case Study.

    PubMed

    Fletcher, Kenneth C; Abbas, Ali E

    2018-05-01

    This article presents a public value measure that can be used to aid executives in the public sector to better assess policy decisions and maximize value to the American people. Using Transportation Security Administration (TSA) programs as an example, we first identify the basic components of public value. We then propose a public value account to quantify the outcomes of various risk scenarios, and we determine the certain equivalent of several important TSA programs. We illustrate how this proposed measure can quantify the effects of two main challenges that government organizations face when conducting enterprise risk management: (1) short-term versus long-term incentives and (2) avoiding potential negative consequences even if they occur with low probability. Finally, we illustrate how this measure enables the use of various tools from decision analysis to be applied in government settings, such as stochastic dominance arguments and certain equivalent calculations. Regarding the TSA case study, our analysis demonstrates the value of continued expansion of the TSA trusted traveler initiative and increasing the background vetting for passengers who are afforded expedited security screening. © 2017 Society for Risk Analysis.

  17. Using Value-Added Measures of Teacher Quality. Brief 9

    ERIC Educational Resources Information Center

    Hanushek, Eric A.; Rivkin, Steven G.

    2010-01-01

    Extensive education research on the contribution of teachers to student achievement produces two generally accepted results. First, teacher quality varies substantially as measured by the value added to student achievement or future academic attainment or earnings. Second, variables often used to determine entry into the profession and…

  18. Measuring the value of accurate link prediction for network seeding.

    PubMed

    Wei, Yijin; Spencer, Gwen

    2017-01-01

    The influence-maximization literature seeks small sets of individuals whose structural placement in the social network can drive large cascades of behavior. Optimization efforts to find the best seed set often assume perfect knowledge of the network topology. Unfortunately, social network links are rarely known in an exact way. When do seeding strategies based on less-than-accurate link prediction provide valuable insight? We introduce optimized-against-a-sample ([Formula: see text]) performance to measure the value of optimizing seeding based on a noisy observation of a network. Our computational study investigates [Formula: see text] under several threshold-spread models in synthetic and real-world networks. Our focus is on measuring the value of imprecise link information. The level of investment in link prediction that is strategic appears to depend closely on spread model: in some parameter ranges investments in improving link prediction can pay substantial premiums in cascade size. For other ranges, such investments would be wasted. Several trends were remarkably consistent across topologies.

  19. Dollar$ & $en$e. Part IV: Measuring the value of people, structural, and customer capital.

    PubMed

    Wilkinson, I

    2001-01-01

    In Part I of this series, I introduced the concept of memes (1). Memes are ideas or concepts, the information world equivalent of genes. The goal of this series of articles is to infect you with my memes, so that you will assimilate, translate, and express them. We discovered that no matter what our area of expertise or "-ology," we all are in the information business. Our goal is to be in the wisdom business. We saw that when we convert raw data into wisdom we are moving along a value chain. Each step in the chain adds a different amount of value to the final product: timely, relevant, accurate, and precise knowledge which can then be applied to create the ultimate product in the value chain: wisdom. In Part II of this series, I infected you with a set of memes for measuring the cost of adding value (2). In Part III of this series, I infected you with a new set of memes for measuring the added value of knowledge, i.e., intellectual capital (3). In Part IV of this series, I will infect you with memes for measuring the value of people, structural, and customer capital.

  20. Reference values of anthropometric measurements in Dutch children. The Oosterwolde Study.

    PubMed

    Gerver, W J; Drayer, N M; Schaafsma, W

    1989-03-01

    In the period 1979-1980 the following anthropometric measurements were recorded in 2351 healthy Dutch children from 0-17 years of age: height, weight, sitting height, arm span, lengths of upper-arm, lower-arm and hand, tibial length, foot length, biacromial diameter, biiliacal diameter, and head circumference. Corresponding percentile values were constructed on the basis of normality assumptions, the mean and standard deviation at age t being determined by a cubic spline approximation. The results are compared with other studies and given in the form of growth charts.

  1. Value of in vivo electrophysiological measurements to evaluate canine small bowel autotransplants.

    PubMed Central

    Meijssen, M A; Heineman, E; de Bruin, R W; Veeze, H J; Bijman, J; de Jonge, H R; ten Kate, F J; Marquet, R L; Molenaar, J C

    1991-01-01

    This study aimed to develop a non-invasive method for in vivo measurement of the transepithelial potential difference in the canine small bowel and to evaluate this parameter in small bowel autotransplants. In group 0 (control group, n = 4), two intestinal loops were created without disturbing their vascular, neural, and lymphatic supplies. In group I (successful autotransplants, n = 11), two heterotopic small bowel loops were constructed. Long term functional sequelae of vascular, neural, and lymphatic division were studied. Group II (n = 6) consisted of dogs with unsuccessful autotransplants suffering thrombosis of the vascular anastomosis, which resulted in ischaemic small bowel autografts. In group I, values of spontaneous transepithelial potential difference, an index of base line active electrolyte transport, were significantly lower compared with group 0 (p less than 0.05), probably as a result of denervation of the autotransplants. Both theophylline and glucose stimulated potential difference responses, measuring cyclic adenosine monophosphate mediated chloride secretion and sodium coupled glucose absorption respectively, showed negative luminal values in group I at all time points after transplantation. These transepithelial potential difference responses diminished progressively with time. From day 21 onwards both theophylline and glucose stimulated potential difference responses were significantly less than the corresponding responses at day seven (p less than 0.05). Morphometric analysis showed that the reduction of transepithelial potential difference responses preceded degenerative mucosal changes in the heterotopic small bowel autografts. In group II, potential difference responses to theophylline and glucose showed positive luminal values (p<0.01 v group I), probably as a result of passive potassium effusion from necrotic enterocytes. Images Figure 3 PMID:1752464

  2. Start a New Fire: Measuring the Value of Academic Libraries in Undergraduate Learning

    ERIC Educational Resources Information Center

    Menchaca, Frank

    2014-01-01

    In the last two decades, fundamental changes in information distribution, in the general economy, and in the behaviors of faculty, students, and library staff have problematized the question of an academic library's value and how it can be measured. This article reviews those changes and, drawing on research linked to the Collegiate Learning…

  3. Measuring Value-at-Risk and Expected Shortfall of crude oil portfolio using extreme value theory and vine copula

    NASA Astrophysics Data System (ADS)

    Yu, Wenhua; Yang, Kun; Wei, Yu; Lei, Likun

    2018-01-01

    Volatilities of crude oil price have important impacts on the steady and sustainable development of world real economy. Thus it is of great academic and practical significance to model and measure the volatility and risk of crude oil markets accurately. This paper aims to measure the Value-at-Risk (VaR) and Expected Shortfall (ES) of a portfolio consists of four crude oil assets by using GARCH-type models, extreme value theory (EVT) and vine copulas. The backtesting results show that the combination of GARCH-type-EVT models and vine copula methods can produce accurate risk measures of the oil portfolio. Mixed R-vine copula is more flexible and superior to other vine copulas. Different GARCH-type models, which can depict the long-memory and/or leverage effect of oil price volatilities, however offer similar marginal distributions of the oil returns.

  4. Calculating meal glycemic index by using measured and published food values compared with directly measured meal glycemic index.

    PubMed

    Dodd, Hayley; Williams, Sheila; Brown, Rachel; Venn, Bernard

    2011-10-01

    Glycemic index (GI) testing is normally based on individual foods, whereas GIs for meals or diets are based on a formula using a weighted sum of the constituents. The accuracy with which the formula can predict a meal or diet GI is questionable. Our objective was to compare the GI of meals, obtained by using the formula and by using both measured food GI and published values, with directly measured meal GIs. The GIs of 7 foods were tested in 30 healthy people. The foods were combined into 3 meals, each of which provided 50 g available carbohydrate, including a staple (potato, rice, or spaghetti), vegetables, sauce, and pan-fried chicken. The mean (95% CI) meal GIs determined from individual food GI values and by direct measurement were as follows: potato meal [predicted, 63 (56, 70); measured, 53 (46, 62)], rice meal [predicted, 51 (45, 56); measured, 38 (33, 45)], and spaghetti meal [predicted, 54 (49, 60); measured, 38 (33, 44)]. The predicted meal GIs were all higher than the measured GIs (P < 0.001). The extent of the overestimation depended on the particular food, ie, 12, 15, and 19 GI units (or 22%, 40%, and 50%) for the potato, rice, and spaghetti meals, respectively. The formula overestimated the GI of the meals by between 22% and 50%. The use of published food values also overestimated the measured meal GIs. Investigators using the formula to calculate a meal or diet GI should be aware of limitations in the method. This trial is registered with the Australian and New Zealand Clinical Trials Registry as ACTRN12611000210976.

  5. Value-Added and Other Methods for Measuring School Performance: An Analysis of Performance Measurement Strategies in Teacher Incentive Fund Proposals. Research Brief

    ERIC Educational Resources Information Center

    National Center on Performance Incentives, 2008

    2008-01-01

    In "Value-Added and Other Methods for Measuring School Performance: An Analysis of Performance Measurement Strategies in Teacher Incentive Fund Proposals"--a paper presented at the February 2008 National Center on Performance Incentives research to policy conference--Robert Meyer and Michael Christian examine select performance-pay plans…

  6. Reference values for developing responsive functional outcome measures across the lifespan.

    PubMed

    McKay, Marnee J; Baldwin, Jennifer N; Ferreira, Paulo; Simic, Milena; Vanicek, Natalie; Burns, Joshua

    2017-04-18

    To generate a reference dataset of commonly performed functional outcome measures in 1,000 children and adults and investigate the influence of demographic, anthropometric, strength, and flexibility characteristics. Twelve functional outcome measures were collected from 1,000 healthy individuals aged 3-101 years: 6-minute walk test, 30-second chair stand test, timed stairs test, long jump, vertical jump, choice stepping reaction time, balance (Star Excursion Balance Test, tandem stance eyes open and closed, single-leg stance eyes closed), and dexterity (9-hole peg test, Functional Dexterity Test). Correlation and multiple regression analyses were performed to identify factors independently associated with each measure. Age- and sex-stratified reference values for functional outcome measures were generated. Functional performance increased through childhood and adolescence, plateaued during adulthood, and declined in older adulthood. While balance did not differ between the sexes, male participants generally performed better at gross motor tasks while female participants performed better at dexterous tasks. Height was the most consistent correlate of functional performance in children, while lower limb muscle strength was a major determinant in adolescents and adults. In older adults, age, lower limb strength, and joint flexibility explained up to 63% of the variance in functional measures. These normative reference values provide a framework to accurately track functional decline associated with neuromuscular disorders and assist development and validation of responsive outcome measures for therapeutic trials. © 2017 American Academy of Neurology.

  7. Strength Measurements in Acute Hamstring Injuries: Intertester Reliability and Prognostic Value of Handheld Dynamometry.

    PubMed

    Reurink, Gustaaf; Goudswaard, Gert Jan; Moen, Maarten H; Tol, Johannes L; Verhaar, Jan A N; Weir, Adam

    2016-08-01

    Study Design Cohort study, repeated measures. Background Although hamstring strength measurements are used for assessing prognosis and monitoring recovery after hamstring injury, their actual clinical relevance has not been established. Handheld dynamometry (HHD) is a commonly used method of measuring muscle strength. The reliability of HHD has not been determined in athletes with acute hamstring injuries. Objectives To determine the intertester reliability and the prognostic value of hamstring HHD strength measurement in acute hamstring injuries. Methods We measured knee flexion strength with HHD in 75 athletes at 2 visits, at baseline (within 5 days of hamstring injury) and follow-up (5 to 7 days after the baseline measurement). We assessed isometric hamstring strength in 15° and 90° of knee flexion. Reliability analysis testing was performed by 2 testers independently at the follow-up visit. We recorded the time needed to return to play (RTP) up to 6 months following baseline. Results The intraclass correlation coefficients of the strength measurements in injured hamstrings were between 0.75 and 0.83. There was a statistically significant but weak correlation between the time to RTP and the strength deficit at 15° of knee flexion measured at baseline (Spearman r = 0.25, P = .045) and at the follow-up visit (Spearman r = 0.26, P = .034). Up to 7% of the variance in time to RTP is explained by this strength deficit. None of the other strength variables were significantly correlated with time to RTP. Conclusion Hamstring strength can be reliably measured with HHD in athletes with acute hamstring injuries. The prognostic value of strength measurements is limited, as there is only a weak association between the time to RTP and hamstring strength deficit after acute injury. Level of Evidence Prognosis, level 4. J Orthop Sports Phys Ther 2016;46(8):689-696. Epub 12 May 2016. doi:10.2519/jospt.2016.6363.

  8. Is Log Ratio a Good Value for Measuring Return in Stock Investments?

    NASA Astrophysics Data System (ADS)

    Ultsch, Alfred

    Measuring the rate of return is an important issue for theory and practice of investments in the stock market. A common measure for rate of return is the logarithm of the ratio of successive prices (LogRatio). In this paper it is shown that LogRatio as well as arithmetic return rate (Ratio) have several disadvantages. As an alternative relative differences (RelDiff) are proposed to measure return. The stability against numerical and rounding errors of RelDiff is much better than for LogRatios and Ratio). RelDiff values are identical to LogRatios and Return for small absolutes. The usage of RelDiff maps returns to a finite range. For most subsequent analyses this is a big advantage. The usefulness of the approach is demonstrated on daily return rates of a large set of actual stocks. It is shown that returns can be modeled with a very simple mixture of distributions in great precision using Relative differences.

  9. Comparing multistate expected damages, option price and cumulative prospect measures for valuing flood protection

    NASA Astrophysics Data System (ADS)

    Farrow, Scott; Scott, Michael

    2013-05-01

    Floods are risky events ranging from small to catastrophic. Although expected flood damages are frequently used for economic policy analysis, alternative measures such as option price (OP) and cumulative prospect value exist. The empirical magnitude of these measures whose theoretical preference is ambiguous is investigated using case study data from Baltimore City. The outcome for the base case OP measure increases mean willingness to pay over the expected damage value by about 3%, a value which is increased with greater risk aversion, reduced by increased wealth, and only slightly altered by higher limits of integration. The base measure based on cumulative prospect theory is about 46% less than expected damages with estimates declining when alternative parameters are used. The method of aggregation is shown to be important in the cumulative prospect case which can lead to an estimate up to 41% larger than expected damages. Expected damages remain a plausible and the most easily computed measure for analysts.

  10. Development and validation of a measure of food choice values.

    PubMed

    Lyerly, Jordan E; Reeve, Charlie L

    2015-06-01

    Food choice values (FCVs) are factors that individuals consider when deciding which foods to purchase and/or consume. Given the potentially important implications for health, it is critical for researchers to have access to a validated measure of FCV. Though there is an existing measure of FCV, this measure was developed 20 years ago and recent research suggests additional FCVs exist that are not included in this measure. A series of four studies was conducted to develop a new expanded measure of FCV. An eight-factor model of FCV was supported and confirmed. In aggregate, results from the four studies indicate that the measure is content valid, and has internally consistent scales that also demonstrated acceptable temporal stability and convergent validity. In addition, the eight scales of the measures were independent of social desirability, met criteria for measurement invariance across income groups, and predicted dietary intake. The development of this new measure of FCV may be useful for researchers examining FCVs (FCVs) in the future, as well as for use in intervention and prevention efforts targeting dietary choices. Copyright © 2015 Elsevier Ltd. All rights reserved.

  11. Valuing vaccines using value of statistical life measures.

    PubMed

    Laxminarayan, Ramanan; Jamison, Dean T; Krupnick, Alan J; Norheim, Ole F

    2014-09-03

    Vaccines are effective tools to improve human health, but resources to pursue all vaccine-related investments are lacking. Benefit-cost and cost-effectiveness analysis are the two major methodological approaches used to assess the impact, efficiency, and distributional consequences of disease interventions, including those related to vaccinations. Childhood vaccinations can have important non-health consequences for productivity and economic well-being through multiple channels, including school attendance, physical growth, and cognitive ability. Benefit-cost analysis would capture such non-health benefits; cost-effectiveness analysis does not. Standard cost-effectiveness analysis may grossly underestimate the benefits of vaccines. A specific willingness-to-pay measure is based on the notion of the value of a statistical life (VSL), derived from trade-offs people are willing to make between fatality risk and wealth. Such methods have been used widely in the environmental and health literature to capture the broader economic benefits of improving health, but reservations remain about their acceptability. These reservations remain mainly because the methods may reflect ability to pay, and hence be discriminatory against the poor. However, willingness-to-pay methods can be made sensitive to income distribution by using appropriate income-sensitive distributional weights. Here, we describe the pros and cons of these methods and how they compare against standard cost-effectiveness analysis using pure health metrics, such as quality-adjusted life years (QALYs) and disability-adjusted life years (DALYs), in the context of vaccine priorities. We conclude that if appropriately used, willingness-to-pay methods will not discriminate against the poor, and they can capture important non-health benefits such as financial risk protection, productivity gains, and economic wellbeing. Copyright © 2014 Elsevier Ltd. All rights reserved.

  12. [The prognostic value of cerebral oxygen saturation measurement for assessing prognosis after cardiopulmonary resuscitation].

    PubMed

    Inal, Mehmet Turan; Memiş, Dilek; Yıldırım, Ilker; Uğur, Hüseyin; Erkaymaz, Aysegul; Turan, F Nesrin

    Despite new improvements on cardiopulmonary resuscitation (CPR), brain damage is very often after resuscitation. To assess the prognostic value of cerebral oxygen saturation measurement (rSO 2 ) for assessing prognosis on patients after cardiopulmonary resuscitation. Retrospective analysis. We analyzed 25 post-CPR patients (12 female and 13 male). All the patients were cooled to a target temperature of 33-34°C. The Glascow Coma Scale (GCS), Corneal Reflexes (CR), Pupillary Reflexes (PR), arterial Base Excess (BE) and rSO 2 measurements were taken on admission. The rewarming GCS, CR, PR, BE and rSO 2 measurements were made after the patient's temperature reached 36°C. In survivors, the baseline rSO 2 value was 67.5 (46-70) and the percent difference between baseline and rewarming rSO 2 value was 0.03 (0.014-0.435). In non-survivors, the baseline rSO 2 value was 30 (25-65) and the percent difference between baseline and rewarming rSO 2 value was 0.031 (-0.08 to -20). No statistical difference was detected on percent changes between baseline and rewarming values of rSO 2. Statistically significant difference was detected between baseline and rewarming GCS groups (p=0.004). No statistical difference was detected between GCS, CR, PR, BE and rSO 2 to determine the prognosis. Despite higher values of rSO 2 on survivors than non-survivors, we found no statistically considerable difference between groups on baseline and the rewarming rSO 2 values. Since the measurement is simple, and not affected by hypotension and hypothermia, the rSO 2 may be a useful predictor for determining the prognosis after CPR. Copyright © 2016 Sociedade Brasileira de Anestesiologia. Publicado por Elsevier Editora Ltda. All rights reserved.

  13. Protocol for fermionic positive-operator-valued measures

    NASA Astrophysics Data System (ADS)

    Arvidsson-Shukur, D. R. M.; Lepage, H. V.; Owen, E. T.; Ferrus, T.; Barnes, C. H. W.

    2017-11-01

    In this paper we present a protocol for the implementation of a positive-operator-valued measure (POVM) on massive fermionic qubits. We present methods for implementing nondispersive qubit transport, spin rotations, and spin polarizing beam-splitter operations. Our scheme attains linear opticslike control of the spatial extent of the qubits by considering ground-state electrons trapped in the minima of surface acoustic waves in semiconductor heterostructures. Furthermore, we numerically simulate a high-fidelity POVM that carries out Procrustean entanglement distillation in the framework of our scheme, using experimentally realistic potentials. Our protocol can be applied not only to pure ensembles with particle pairs of known identical entanglement, but also to realistic ensembles of particle pairs with a distribution of entanglement entropies. This paper provides an experimentally realizable design for future quantum technologies.

  14. The VALS: A new tool to measure people's general valued attributes of landscapes.

    PubMed

    Kendal, Dave; Ford, Rebecca M; Anderson, Nerida M; Farrar, Alison

    2015-11-01

    Research on values for natural areas has largely focussed on theoretical concerns such as distinguishing different kinds of values held by people. However practice, policymaking, planning and management is typically focused on more tangible valued attributes of the landscape such as biodiversity and recreation infrastructure that can be manipulated by management actions. There is a need for valid psychometric measures of such values that are suited to informing land management policies. A Valued Attributes of Landscape Scale (VALS) was developed, derived from a document analysis of values expressed in public land policy documents. The validity of the VALS was tested in an online survey comparing values across one of three randomly presented landscape contexts in Victoria, Australia: all publicly managed natural land, coastal areas, and large urban parks. A purposive snowball sample was used to recruit participants with a range of views and professional experience with land management, including members of the urban public. Factor analysis of responses (n = 646) separated concepts relating to natural attributes, social functions, the experience of being in natural areas, cultural attributes and productive uses. Relative importance of valued attribute factors was similar across all landscape contexts, although there were small but significant differences in the way people valued social functions (higher in urban parks) and productive uses (lower in urban parks). We conclude that the concept of valued attributes is useful for linking theoretical understandings of people's environmental values to the way values are considered by land managers, and that these attributes can be measured using the VALS instrument to produce data that should be useful for the policy and planning of natural resources. Copyright © 2015 Elsevier Ltd. All rights reserved.

  15. Student-Valued Measurable Teaching Behaviors of Award-Winning Pharmacy Preceptors.

    PubMed

    O'Sullivan, Teresa A; Lau, Carmen; Patel, Mitul; Mac, Chi; Krueger, Janelle; Danielson, Jennifer; Weber, Stanley S

    2015-12-25

    To identify specific preceptor teaching-coaching, role modeling, and facilitating behaviors valued by pharmacy students and to develop measures of those behaviors that can be used for an experiential education quality assurance program. Using a qualitative research approach, we conducted a thematic analysis of student comments about excellent preceptors to identify behaviors exhibited by those preceptors. Identified behaviors were sorted according to the preceptor's role as role model, teacher/coach, or learning facilitator; measurable descriptors for each behavior were then developed. Data analysis resulted in identification of 15 measurable behavior themes, the most frequent being: having an interest in student learning and success, making time for students, and displaying a positive preceptor attitude. Measureable descriptors were developed for 5 role-modeling behaviors, 6 teaching-coaching behaviors, and 4 facilitating behaviors. Preceptors may need to be evaluated in their separate roles as teacher-coach, role model, and learning facilitator. The developed measures in this report could be used in site quality evaluation.

  16. Effects of caffeine on fractional flow reserve values measured using intravenous adenosine triphosphate.

    PubMed

    Nakayama, Masafumi; Chikamori, Taishiro; Uchiyama, Takashi; Kimura, Yo; Hijikata, Nobuhiro; Ito, Ryosuke; Yuhara, Mikio; Sato, Hideaki; Kobori, Yuichi; Yamashina, Akira

    2018-04-01

    We investigated the effects of caffeine intake on fractional flow reserve (FFR) values measured using intravenous adenosine triphosphate (ATP) before cardiac catheterization. Caffeine is a competitive antagonist for adenosine receptors; however, it is unclear whether this antagonism affects FFR values. Patients were evenly randomized into 2 groups preceding the FFR study. In the caffeine group (n = 15), participants were given coffee containing 222 mg of caffeine 2 h before the catheterization. In the non-caffeine group (n = 15), participants were instructed not to take any caffeine-containing drinks or foods for at least 12 h before the catheterization. FFR was performed in patients with more than intermediate coronary stenosis using the intravenous infusion of ATP at 140 μg/kg/min (normal dose) and 170 μg/kg/min (high dose), and the intracoronary infusion of papaverine. FFR was followed for 30 s after maximal hyperemia. In the non-caffeine group, the FFR values measured with ATP infusion were not significantly different from those measured with papaverine infusion. However, in the caffeine group, the FFR values were significantly higher after ATP infusion than after papaverine infusion (P = 0.002 and P = 0.007, at normal and high dose ATP vs. papaverine, respectively). FFR values with ATP infusion were significantly increased 30 s after maximal hyperemia (P = 0.001 and P < 0.001 for normal and high dose ATP, respectively). The stability of the FFR values using papaverine showed no significant difference between the 2 groups. Caffeine intake before the FFR study affected FFR values and their stability. These effects could not be reversed by an increased ATP dose.

  17. Method and apparatus for real-time measurement of fuel gas compositions and heating values

    DOEpatents

    Zelepouga, Serguei; Pratapas, John M.; Saveliev, Alexei V.; Jangale, Vilas V.

    2016-03-22

    An exemplary embodiment can be an apparatus for real-time, in situ measurement of gas compositions and heating values. The apparatus includes a near infrared sensor for measuring concentrations of hydrocarbons and carbon dioxide, a mid infrared sensor for measuring concentrations of carbon monoxide and a semiconductor based sensor for measuring concentrations of hydrogen gas. A data processor having a computer program for reducing the effects of cross-sensitivities of the sensors to components other than target components of the sensors is also included. Also provided are corresponding or associated methods for real-time, in situ determination of a composition and heating value of a fuel gas.

  18. Effect of sampling location on L* values and pH measurements and their relationship in broiler breast fillets

    USDA-ARS?s Scientific Manuscript database

    Lightness (CIELAB L*) and pH values are the most widely measured quality indicators for broiler breast fillets (pectoralis major). Measurement of L* values with a spectrophotometer can be done through Specular Component Included (SCI) or Specular Component Excluded (SCE) modes. The intra-fillet loca...

  19. Measuring daily Value-at-Risk of SSEC index: A new approach based on multifractal analysis and extreme value theory

    NASA Astrophysics Data System (ADS)

    Wei, Yu; Chen, Wang; Lin, Yu

    2013-05-01

    Recent studies in the econophysics literature reveal that price variability has fractal and multifractal characteristics not only in developed financial markets, but also in emerging markets. Taking high-frequency intraday quotes of the Shanghai Stock Exchange Component (SSEC) Index as example, this paper proposes a new method to measure daily Value-at-Risk (VaR) by combining the newly introduced multifractal volatility (MFV) model and the extreme value theory (EVT) method. Two VaR backtesting techniques are then employed to compare the performance of the model with that of a group of linear and nonlinear generalized autoregressive conditional heteroskedasticity (GARCH) models. The empirical results show the multifractal nature of price volatility in Chinese stock market. VaR measures based on the multifractal volatility model and EVT method outperform many GARCH-type models at high-risk levels.

  20. Stability of Teacher Value-Added Rankings across Measurement Model and Scaling Conditions

    ERIC Educational Resources Information Center

    Hawley, Leslie R.; Bovaird, James A.; Wu, ChaoRong

    2017-01-01

    Value-added assessment methods have been criticized by researchers and policy makers for a number of reasons. One issue includes the sensitivity of model results across different outcome measures. This study examined the utility of incorporating multivariate latent variable approaches within a traditional value-added framework. We evaluated the…

  1. The Math-Biology Values Instrument: Development of a Tool to Measure Life Science Majors' Task Values of Using Math in the Context of Biology.

    PubMed

    Andrews, Sarah E; Runyon, Christopher; Aikens, Melissa L

    2017-01-01

    In response to calls to improve the quantitative training of undergraduate biology students, there have been increased efforts to better integrate math into biology curricula. One challenge of such efforts is negative student attitudes toward math, which are thought to be particularly prevalent among biology students. According to theory, students' personal values toward using math in a biological context will influence their achievement and behavioral outcomes, but a validated instrument is needed to determine this empirically. We developed the Math-Biology Values Instrument (MBVI), an 11-item college-level self--report instrument grounded in expectancy-value theory, to measure life science students' interest in using math to understand biology, the perceived usefulness of math to their life science career, and the cost of using math in biology courses. We used a process that integrates multiple forms of validity evidence to show that scores from the MBVI can be used as a valid measure of a student's value of math in the context of biology. The MBVI can be used by instructors and researchers to help identify instructional strategies that influence math-biology values and understand how math-biology values are related to students' achievement and decisions to pursue more advanced quantitative-based courses. © 2017 S. E. Andrews et al. CBE—Life Sciences Education © 2017 The American Society for Cell Biology. This article is distributed by The American Society for Cell Biology under license from the author(s). It is available to the public under an Attribution–Noncommercial–Share Alike 3.0 Unported Creative Commons License (http://creativecommons.org/licenses/by-nc-sa/3.0).

  2. We do not know what we do not know: innovative approaches to value measurement.

    PubMed

    Laviana, Aaron A; Resnick, Matthew J

    2018-07-01

    Over the past several years, there has been an increasing focus on improving the 'value' of healthcare delivered, defined as the ratio of clinical outcomes to the costs incurred to achieve them. The former U.S. Secretary of Health and Human Services Sylvia Burwell announced in 2015 that the majority of healthcare payments in the Medicare and Medicaid programmes will align with value by 2018. Although this has yet to fully mature, numerous health systems have restructured with a goal of improving the value of care delivered to their populations. Nevertheless, there remain important unanswered questions regarding how we measure value in the current U.S. healthcare system. The purpose of this review is to highlight innovations that are not only making it easier to measure value but also to improve care from the patient, provider and healthcare system perspectives. Behavioural start-ups and the introduction of relatively inexpensive health coaches are starting to permeate the healthcare landscape. These coaches are the consumers' advocate, acting as the quarterback of an extended care team in order to optimize health. Furthermore, time-driven activity-based costing has allowed us to understand costs on a more granular level, and novel tracking software may further automate these costing algorithms in order to better facilitate their dissemination. We must all work to enable new models of care that improve value by incentivizing individuals, payers and providers to improve health, rather than treat the disease after it manifests. We must also continue to improve the efficiency of healthcare delivery largely through improvements in value measurement.

  3. Valuation of Green Walls and Green Roofs as Soundscape Measures: Including Monetised Amenity Values Together with Noise-attenuation Values in a Cost-benefit Analysis of a Green Wall Affecting Courtyards

    PubMed Central

    Veisten, Knut; Smyrnova, Yuliya; Klæboe, Ronny; Hornikx, Maarten; Mosslemi, Marjan; Kang, Jian

    2012-01-01

    Economic unit values of soundscape/acoustic effects have been based on changes in the number of annoyed persons or on decibel changes. The normal procedure has been the application of these unit values to noise-attenuation measures affecting the noisier façade of a dwelling. Novel modular vegetation-based soundscape measures, so-called green walls, might be relevant for both noisy and quieter areas. Moreover, their benefits will comprise noise attenuation as well as non-acoustic amenity effects. One challenge is to integrate the results of some decades of non-acoustic research on the amenity value of urban greenery into design of the urban sound environment, and incorporate these non-acoustic properties in the overall economic assessment of noise control and overall sound environment improvement measures. Monetised unit values for green walls have been included in two alternative cases, or demonstration projects, of covering the entrances to blocks of flats with a green wall. Since these measures improve the noise environment on the quiet side of the dwellings and courtyards, not the most exposed façade, adjustment factors to the nominal quiet side decibel reductions to arrive at an estimate of the equivalent overall acoustic improvement have been applied. A cost-benefit analysis of the green wall case indicates that this measure is economically promising, when valuing the noise attenuation in the quieter area and adding the amenity/aesthetic value of the green wall. PMID:23202816

  4. Reporting the national antimicrobial consumption in Danish pigs: influence of assigned daily dosage values and population measurement.

    PubMed

    Dupont, Nana; Fertner, Mette; Kristensen, Charlotte Sonne; Toft, Nils; Stege, Helle

    2016-05-03

    Transparent calculation methods are crucial when investigating trends in antimicrobial consumption over time and between populations. Until 2011, one single standardized method was applied when quantifying the Danish pig antimicrobial consumption with the unit "Animal Daily Dose" (ADD). However, two new methods for assigning values for ADDs have recently emerged, one implemented by DANMAP, responsible for publishing annual reports on antimicrobial consumption, and one by the Danish Veterinary and Food Administration (DVFA), responsible for the Yellow Card initiative. In addition to new ADD assignment methods, Denmark has also experienced a shift in the production pattern, towards a larger export of live pigs. The aims of this paper were to (1) describe previous and current ADD assignment methods used by the major Danish institutions and (2) to illustrate how ADD assignment method and choice of population and population measurement affect the calculated national antimicrobial consumption in pigs (2007-2013). The old VetStat ADD-values were based on SPCs in contrast to the new ADD-values, which were based on active compound, concentration and administration route. The new ADD-values stated by both DANMAP and DVFA were only identical for 48 % of antimicrobial products approved for use in pigs. From 2007 to 2013, the total number of ADDs per year increased by 9 % when using the new DVFA ADD-values, but decreased by 2 and 7 % when using the new DANMAP ADD-values or the old VetStat ADD-values, respectively. Through 2007 to 2013, the production of pigs increased from 26.1 million pigs per year with 18 % exported live to 28.7 million with 34 % exported live. In the same time span, the annual pig antimicrobial consumption increased by 22.2 %, when calculated using the new DVFA ADD-values and pigs slaughtered per year as population measurement (13.0 ADDs/pig/year to 15.9 ADDs/pig/year). However, when based on the old VetStat ADD values and pigs produced per year

  5. Value-Added Measures of Education Performance: Clearing Away the Smoke and Mirrors. Policy Brief 10-4

    ERIC Educational Resources Information Center

    Harris, Douglas N.

    2010-01-01

    In this policy brief, the author explores the problems with attainment measures when it comes to evaluating performance at the school level, and explores the best uses of value-added measures. These value-added measures, the author writes, are useful for sorting out-of-school influences from school influences or from teacher performance, giving…

  6. Measuring Work Values of Public School Administrators.

    ERIC Educational Resources Information Center

    Hales, Loyde W.; Waggoner, Jacqueline

    This paper presents the results of research investigating (1) the reliability and validity of the Ohio Work Values Inventory (OWVI) when used with public school administrators; (2) the work values of public school administrators; (3) differences in work values of male and female administrators; and (4) differences in work values of individuals at…

  7. Examining the Perceived Value of Integration of Earned Value Management with Risk Management-Based Performance Measurement Baseline

    ERIC Educational Resources Information Center

    Shah, Akhtar H.

    2014-01-01

    Many projects fail despite the use of evidence-based project management practices such as Performance Measurement Baseline (PMB), Earned Value Management (EVM) and Risk Management (RM). Although previous researchers have found that integrated project management techniques could be more valuable than the same techniques used by themselves, these…

  8. Measuring the value of nonwage employee benefits: building a model of the relation between benefit satisfaction and value.

    PubMed

    Weathington, Bart L; Jones, Allan P

    2006-11-01

    Researchers have commonly assumed benefits that employees view as more valuable have a greater influence on their attitudes and behaviors. Researchers have used 2 common methods to measure benefit value: attaching a monetary value to benefits and using self-reports of benefit importance. The present authors propose that the 2 approaches are conceptually distinct and have different implications. They use a social exchange perspective to justify this distinction and integrate both approaches and benefit satisfaction into a more comprehensive model of benefit perception. Results suggest that both measures have practical applications depending on the nature of the exchange relationship between the organization and employees. However, this relationship depends on the specific benefit and on employee satisfaction with that benefit. Some benefits lend themselves to a monetary estimate, whereas others lend themselves more to a nonmonetary valuation.

  9. Social value orientation: theoretical and measurement issues in the study of social preferences.

    PubMed

    Murphy, Ryan O; Ackermann, Kurt A

    2014-02-01

    What motivates people when they make decisions and how those motivations are potentially entangled with concerns for others are central topics for the social, cognitive, and behavioral sciences. According to the postulate of narrow self-interest, decision makers have the goal of maximizing personal payoffs and are wholly indifferent to the consequences for others. The postulate of narrow self-interest-which has been influential in economics, psychology, and sociology-is precise and powerful but is often simply wrong. Its inadequacy is well known and efforts have been made to develop reliable and valid measurement methods to quantify the more nuanced social preferences that people really have. In this paper, we report on the emergence and development of the predominant conceptualization of social preferences in psychology: social value orientation (SVO). Second, we discuss the relationship between measurement and theory development of the SVO construct. We then provide an overview of the literature regarding measurement methods that have been used to assess individual variations in social preferences. We conclude with a comparative evaluation of the various measures and provide suggestions regarding the measures' constructive use in building psychologically realistic theories of people's social preferences.

  10. On nonepistemic values in conservation biology.

    PubMed

    Baumgaertner, Bert; Holthuijzen, Wieteke

    2017-02-01

    Conservation biology is a uniquely interdisciplinary science with strong roots in ecology, but it also embraces a value-laden and mission-oriented framework. This combination of science and values causes conservation biology to be at the center of critique regarding the discipline's scientific credibility-especially the division between the realms of theory and practice. We identify this dichotomy between seemingly objective (fact-based) and subjective (value-laden) practices as the measure-value dichotomy, whereby measure refers to methods and analyses used in conservation biology (i.e., measuring biodiversity) and value refers to nonepistemic values. We reviewed and evaluated several landmark articles central to the foundation of conservation biology and concepts of biodiversity with respect to their attempts to separate measures and values. We argue that the measure-value dichotomy is false and that conservation biology can make progress in ways unavailable to other disciplines because its practitioners are tasked with engaging in both the realm of theory and the realm of practice. The entanglement of measures and values is by no means a weakness of conservation biology. Because central concepts such as biodiversity contain both factual and evaluative aspects, conservation biologists can make theoretical progress by examining, reviewing, and forming the values that are an integral part of those concepts. We suggest that values should be included and analyzed with respect to the methods, results, and conclusions of scientific work in conservation biology. © 2016 Society for Conservation Biology.

  11. Measuring the value of endoscopic retrograde cholangiopancreatography activity: an opportunity to stratify endoscopists on the basis of their value.

    PubMed

    Parihar, Vikrant; Moran, Carthage; Maheshwari, Pardeep; Cheriyan, Danny; O'Toole, Aoibhlinn; Murray, Frank; Patchett, Stephen E; Harewood, Gavin C

    2018-07-01

    As finite healthcare resources come under pressure, the value of physician activity is assuming increasing importance. The value in healthcare can be defined as patient health outcomes achieved per monetary unit spent. Even though some attempts have been made to quantify the value of clinician activity, there is little in the medical literature describing the importance of endoscopists' activity. This study aimed to characterize the value of endoscopic retrograde cholangiopancreatography (ERCP) performance of five gastroenterologists. We carried out a retrospective-prospective cohort study using the databases of patients undergoing ERCP between September 2014 and March 2017. We collected data from 1070 patients who underwent ERCP comparing value among the ERCPists at index ERCP. Procedure value was calculated using the formula Q/(T/C), where Q is the quality of procedure, T is the duration of procedure and C is the adjusted for complexity level. Quality and complexity were derived on a 1-4 Likert scale on the basis of American Society for Gastrointestinal Endoscopy criteria; time was recorded (in min) from intubation to extubation. Endoscopist time calculated from procedure time was considered a surrogate marker of cost as individual components of procedure cost were not itemized. In total, 590 procedures were analysed: 465 retrospectively over 24 months and 125 prospectively over 6 months. There was a 32% variation in the value of endoscopist activity in a more substantial retrospective cohort, with an even more considerable 73% variation in a smaller prospective arm. In an analysis of greater than 1000 ERCPs by a small cohort of experienced ERCPists, there was a wide variation in the value of endoscopist activity. Although the precision of estimating procedural costs needs further refinement, these findings show the ability to stratify ERCPists on the basis of the value their activity. As healthcare costs are scrutinized more closely, such value measurements are

  12. CBF measured by Xe-CT: Approach to analysis and normal values

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Yonas, H.; Darby, J.M.; Marks, E.C.

    1991-09-01

    Normal reference values and a practical approach to CBF analysis are needed for routine clinical analysis and interpretation of xenon-enhanced computed tomography (CT) CBF studies. The authors measured CBF in 67 normal individuals with the GE 9800 CT scanner adapted for CBF imaging with stable Xe. CBF values for vascular territories were systematically analyzed using the clustering of contiguous 2-cm circular regions of interest (ROIs) placed within the cortical mantle and basal ganglia. Mixed cortical flows averaged 51 {plus minus} 10ml.100g-1.min-1. High and low flow compartments, sampled by placing 5-mm circular ROIs in regions containing the highest and lowest flowmore » values in each hemisphere, averaged 84 {plus minus} 14 and 20 {plus minus} 5 ml.100 g-1.min-1, respectively. Mixed cortical flow values as well as values within the high flow compartment demonstrated significant decline with age; however, there were no significant age-related changes in the low flow compartment. The clustering of systematically placed cortical and subcortical ROIs has provided a normative data base for Xe-CT CBF and a flexible and uncomplicated method for the analysis of CBF maps generated by Xe-enhanced CT.« less

  13. Hospitals Known for Nursing Excellence Perform Better on Value Based Purchasing Measures

    PubMed Central

    Lasater, Karen B.; Germack, Hayley D.; Small, Dylan S.; McHugh, Matthew D.

    2018-01-01

    It is well-established that hospitals recognized for good nursing care – Magnet hospitals – are associated with better patient outcomes. Less is known about how Magnet hospitals compare to non-Magnets on quality measures linked to Medicare reimbursement. The purpose of this study was to determine how Magnet hospitals perform compared to matched non-Magnet hospitals on Hospital Value Based Purchasing (VBP) measures. A cross-sectional analysis of three linked data sources was performed. The sample included 3,021 non-federal acute care hospitals participating in the VBP program (323 Magnets; 2,698 non-Magnets). Propensity score matching was used to match Magnet and non-Magnet hospitals with similar hospital characteristics. After matching, linear and logistic regression models were used to examine the relationship between Magnet status and VBP performance. After matching and adjusting for hospital characteristics, Magnet recognition predicted higher scores on Total Performance (Regression Coefficient [RC] = 1.66, p < 0.05), Clinical Processes (RC = 3.85; p < 0.01), and Patient Experience (RC = 6.33; p < 0.001). The relationships between Magnet recognition and the Outcome and Efficiency domains were not statistically significant. Magnet hospitals known for nursing excellence perform better on Hospital VBP measures. As healthcare systems adapt to evolving incentives that reward value, attention to nurses at the front lines may be central to ensuring high-value care for patients. PMID:28558604

  14. Epidemiological, demographic, and economic analyses: measurement of the value of trichiasis surgery in The Gambia.

    PubMed

    Frick, K D; Keuffel, E L; Bowman, R J

    2001-07-01

    Untreated trichiasis can lead to corneal opacity. Surgery to prevent the eyelashes from rubbing against the cornea is available, but many individuals with trichiasis never undergo the operation. This study estimates the cost of illness of untreated trichiasis and the willingness to pay for surgery and compares them with the actual cost of providing surgery. The cost of illness estimate is based on trichiasis patient demographics. Data on the implicit price of obtaining surgery and surgical utilization in a matched pair randomized trial are used to infer individual willingness to pay for trichiasis surgery. Patients in the study paid nothing out-of-pocket for surgery; the price of obtaining surgery is the value of the individual's time needed for travel and surgery plus the price of public transportation. The cost of producing surgery was calculated from project records. All monetary figures are reported in 1998 US dollars. The average cost of untreated trichiasis, or the net present value of life-time lost economic productivity, was $89. Individuals facing a lower cost were more likely to undergo an operation; the inferred average willingness to pay was $1.43 (SD 0.244). Surgery cost $6.13 to provide, including $0.86 for transportation to the village. Whether the value of trichiasis surgery exceeds the cost in The Gambia depends on how the value is measured. Individuals are willing to use only limited resources to obtain surgery even though lifetime economic productivity may increase substantially. All three economic measures can be used to inform policy.

  15. Microwave measurements of the absolute values of absorption by water vapour in the atmosphere.

    PubMed

    Hogg, D C; Guiraud, F O

    1979-05-31

    MEASUREMENT of the absolute value of absorption by water vapour at microwave frequencies is difficult because the effect is so small. Far in the wings of the absorption lines, in the so-called 'windows' of the spectrum, it is especially difficult to achieve high accuracy in the free atmosphere. But it is in these windows that the behaviour of the absorption is important from both applied and scientific points of view. Satellite communications, remote sensing of the atmosphere, and radioastronomy, are all influenced by this behaviour. Measurements on an Earth-space path are reported here; the results indicate a nonlinear relationship between absorption and water-vapour content.

  16. Challenges in measuring and valuing productivity costs, and their relevance in mood disorders

    PubMed Central

    Lensberg, Benedikte R; Drummond, Michael F; Danchenko, Natalya; Despiégel, Nicolas; François, Clément

    2013-01-01

    Lost productivity is often excluded from economic evaluations, which may lead to an underestimation of the societal benefits of treatment. However, there are multiple challenges in reliably estimating and reporting productivity losses. This article explores the main challenges, ie, selecting an appropriate valuation method (ie, human capital, friction cost, or multiplier), avoiding double counting, and accounting for equity. It also discusses the use of presenteeism instruments and their application in clinical trials, with a specific focus on their relevance in individuals with mood disorders. Further research and discussion is required on the development of reliable techniques for measuring and valuing productivity changes due to presenteeism. PMID:24273412

  17. Measuring What People Value: A Comparison of “Attitude” and “Preference” Surveys

    PubMed Central

    Phillips, Kathryn A; Johnson, F Reed; Maddala, Tara

    2002-01-01

    Objective To compare and contrast methods and findings from two approaches to valuation used in the same survey: measurement of “attitudes” using simple rankings and ratings versus measurement of “preferences” using conjoint analysis. Conjoint analysis, a stated preference method, involves comparing scenarios composed of attribute descriptions by ranking, rating, or choosing scenarios. We explore possible explanations for our findings using focus groups conducted after the quantitative survey. Methods A self-administered survey, measuring attitudes and preferences for HIV tests, was conducted at HIV testing sites in San Francisco in 1999–2000 (n = 365, response rate=96 percent). Attitudes were measured and analyzed using standard approaches. Conjoint analysis scenarios were developed using a fractional factorial design and results analyzed using random effects probit models. We examined how the results using the two approaches were both similar and different. Results We found that “attitudes” and “preferences” were generally consistent, but there were some important differences. Although rankings based on the attitude and conjoint analysis surveys were similar, closer examination revealed important differences in how respondents valued price and attributes with “halo” effects, variation in how attribute levels were valued, and apparent differences in decision-making processes. Conclusions To our knowledge, this is the first study to compare attitude surveys and conjoint analysis surveys and to explore the meaning of the results using post-hoc focus groups. Although the overall findings for attitudes and preferences were similar, the two approaches resulted in some different conclusions. Health researchers should consider the advantages and limitations of both methods when determining how to measure what people value. PMID:12546291

  18. Using the New Postacute Care Quality Measures to Demonstrate the Value of Occupational Therapy.

    PubMed

    Sandhu, Sharmila; Furniss, Jeremy; Metzler, Christina

    As the health care system continues to evolve toward one based on quality not quantity, demonstrating the value of occupational therapy has never been more important. Providing high-quality services, achieving optimal outcomes, and identifying and promoting occupational therapy's distinct value are the responsibilities of all practitioners. In relation to the Improving Medicare Post-Acute Care Transformation (IMPACT) Act of 2014, the Centers for Medicare and Medicaid Services (CMS) is implementing new functional items and related outcome performance measures across postacute care (PAC) settings. Practitioners can demonstrate the role and value of occupational therapy services through their participation in data collection and the interpretation of the resulting performance measures. In this column, we review the objectives of the IMPACT Act, introduce the new self-care and mobility items and outcome performance measures being implemented in PAC settings, and describe ways to use these new data to advocate for occupational therapy. We also discuss American Occupational Therapy Association initiatives to provide materials and guidance for occupational therapy practitioners to contribute to PAC data collection. Copyright © 2018 by the American Occupational Therapy Association, Inc.

  19. The value of routine blood pressure measurement in children presenting to the emergency department with nonurgent problems.

    PubMed

    Stewart, Jessica N; McGillivray, David; Sussman, John; Foster, Bethany

    2008-10-01

    Blood pressure (BP) is measured at triage in most emergency departments (EDs). We aimed to determine the value of triage BP in diagnosing hypotension and true hypertension in children age > or =3 years presenting with nonurgent problems. In this prospective study, eligible children underwent automated BP measurement at triage. If BP was elevated, then the measurement was repeated manually. Children with a high manual BP were followed. True hypertension was defined as a manual BP >95th percentile for sex, age, and height measured on 3 occasions. Automated triage BP was measured in 549 children (53.4% male; mean age, 9.4 +/- 4.3 years) and was found to be elevated in 144 of them (26%). No child was hypotensive. Among the 495 patients with complete follow-up, the specificity and positive predictive value (PPV) of elevated triage BP in diagnosing true hypertension were 81.8% and 0%, respectively. A sensitivity analysis including those with incomplete follow-up, in which the population prevalence of true hypertension was assumed to be 1% to 2%, resulted in a specificity of 74.5% to 75.3% and a PPV of 3.8% to 7.5%. The yield of measuring BP at triage in children with nonurgent problems appears to be extremely low.

  20. Singular value description of a digital radiographic detector: Theory and measurements

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Kyprianou, Iacovos S.; Badano, Aldo; Gallas, Brandon D.

    The H operator represents the deterministic performance of any imaging system. For a linear, digital imaging system, this system operator can be written in terms of a matrix, H, that describes the deterministic response of the system to a set of point objects. A singular value decomposition of this matrix results in a set of orthogonal functions (singular vectors) that form the system basis. A linear combination of these vectors completely describes the transfer of objects through the linear system, where the respective singular values associated with each singular vector describe the magnitude with which that contribution to the objectmore » is transferred through the system. This paper is focused on the measurement, analysis, and interpretation of the H matrix for digital x-ray detectors. A key ingredient in the measurement of the H matrix is the detector response to a single x ray (or infinitestimal x-ray beam). The authors have developed a method to estimate the 2D detector shift-variant, asymmetric ray response function (RRF) from multiple measured line response functions (LRFs) using a modified edge technique. The RRF measurements cover a range of x-ray incident angles from 0 deg. (equivalent location at the detector center) to 30 deg. (equivalent location at the detector edge) for a standard radiographic or cone-beam CT geometric setup. To demonstrate the method, three beam qualities were tested using the inherent, Lu/Er, and Yb beam filtration. The authors show that measures using the LRF, derived from an edge measurement, underestimate the system's performance when compared with the H matrix derived using the RRF. Furthermore, the authors show that edge measurements must be performed at multiple directions in order to capture rotational asymmetries of the RRF. The authors interpret the results of the H matrix SVD and provide correlations with the familiar MTF methodology. Discussion is made about the benefits of the H matrix technique with regards to

  1. New method of measuring low values of dielectric loss in the near millimetre wavelength region using untuned cavities

    NASA Astrophysics Data System (ADS)

    Llewellyn-Jones, D. T.; Knight, R. J.; Moffat, P. H.; Gebbie, H. A.

    1980-11-01

    In the near millimeter-wavelength region, low values of dielectric loss in a material can be readily measured by inserting a sample into an untuned cavity resonator. The high-Q values of the cavities give the technique great sensitivity to low values of loss tangent and, in contrast to other techniques, place very few restrictions on the shape, size, and position of the sample. The technique is demonstrated by measurements at 156 GHz on several polymer materials whose low loss factors are of practical interest. It is shown that the loading of an untuned cavity by a solid sample of low loss is proportional to its absorption cross section, which is the product of its volume and its linear absorption coefficient in the trivial case of n = 1. In the usual case of n greater than 1, reflection at the boundaries will affect the measured cross section in a way that has been investigated experimentally for a number of shapes, both simple and complex, and theoretically for the specific cases of slabs and cubes.

  2. Quality, Safety, Value: From Theory to Practice Management What Should We Measure?

    PubMed

    Shore, Benjamin J; Murphy, Robert F; Hogue, Grant D

    2015-01-01

    Over the past 35 years the health care community and in particular orthopaedic surgery, has undergone a transformation from retrospective case-series-based expert opinion to randomized prospective clinical trials. During this transition, orthopaedic surgeons have become very skilled in the measurement of physician-derived outcomes (radiographic angles, complications, recurrences, and mortality); however, these are not patient-centered outcomes and they are of little importance to our patients' satisfaction. Moving forward outcome measurement needs to be restructured to focus more on patient-reported outcomes. This paper outlines why outcome measurement is important, reviews outcome strategies that have been used historically, introduces a new outcome measurement tool and identifies strategies for future implementation and measurement of health care quality and value within pediatric orthopaedics.

  3. Alternative method of quantum state tomography toward a typical target via a weak-value measurement

    NASA Astrophysics Data System (ADS)

    Chen, Xi; Dai, Hong-Yi; Yang, Le; Zhang, Ming

    2018-03-01

    There is usually a limitation of weak interaction on the application of weak-value measurement. This limitation dominates the performance of the quantum state tomography toward a typical target in the finite and high-dimensional complex-valued superposition of its basis states, especially when the compressive sensing technique is also employed. Here we propose an alternative method of quantum state tomography, presented as a general model, toward such typical target via weak-value measurement to overcome such limitation. In this model the pointer for the weak-value measurement is a qubit, and the target-pointer coupling interaction is no longer needed within the weak interaction limitation, meanwhile this interaction under the compressive sensing can be described with the Taylor series of the unitary evolution operator. The postselection state at the target is the equal superposition of all basis states, and the pointer readouts are gathered under multiple Pauli operator measurements. The reconstructed quantum state is generated from an optimization algorithm of total variation augmented Lagrangian alternating direction algorithm. Furthermore, we demonstrate an example of this general model for the quantum state tomography toward the planar laser-energy distribution and discuss the relations among some parameters at both our general model and the original first-order approximate model for this tomography.

  4. MEthods of ASsessing blood pressUre: identifying thReshold and target valuEs (MeasureBP): a review & study protocol.

    PubMed

    Blom, Kimberly C; Farina, Sasha; Gomez, Yessica-Haydee; Campbell, Norm R C; Hemmelgarn, Brenda R; Cloutier, Lyne; McKay, Donald W; Dawes, Martin; Tobe, Sheldon W; Bolli, Peter; Gelfer, Mark; McLean, Donna; Bartlett, Gillian; Joseph, Lawrence; Featherstone, Robin; Schiffrin, Ernesto L; Daskalopoulou, Stella S

    2015-04-01

    Despite progress in automated blood pressure measurement (BPM) technology, there is limited research linking hard outcomes to automated office BPM (OBPM) treatment targets and thresholds. Equivalences for automated BPM devices have been estimated from approximations of standardized manual measurements of 140/90 mmHg. Until outcome-driven targets and thresholds become available for automated measurement methods, deriving evidence-based equivalences between automated methods and standardized manual OBPM is the next best solution. The MeasureBP study group was initiated by the Canadian Hypertension Education Program to close this critical knowledge gap. MeasureBP aims to define evidence-based equivalent values between standardized manual OBPM and automated BPM methods by synthesizing available evidence using a systematic review and individual subject-level data meta-analyses. This manuscript provides a review of the literature and MeasureBP study protocol. These results will lay the evidenced-based foundation to resolve uncertainties within blood pressure guidelines which, in turn, will improve the management of hypertension.

  5. A Research on Performance Measurement Based on Economic Valued-Added Comprehensive Scorecard

    NASA Astrophysics Data System (ADS)

    Chen, Qin; Zhang, Xiaomei

    With the development of economic, the traditional performance mainly rely on financial indicators could not satisfy the need of work. In order to make the performance measurement taking the best services for business goals, this paper proposed Economic Valued-Added Comprehensive Scorecard based on research of shortages and advantages of EVA and BSC .We used Analytic Hierarchy Process to build matrix to solve the weighting of EVA Comprehensive Scorecard. At last we could find the most influence factors for enterprise value forming the weighting.

  6. Measuring the value of process improvement initiatives in a preoperative assessment center using time-driven activity-based costing.

    PubMed

    French, Katy E; Albright, Heidi W; Frenzel, John C; Incalcaterra, James R; Rubio, Augustin C; Jones, Jessica F; Feeley, Thomas W

    2013-12-01

    The value and impact of process improvement initiatives are difficult to quantify. We describe the use of time-driven activity-based costing (TDABC) in a clinical setting to quantify the value of process improvements in terms of cost, time and personnel resources. Difficulty in identifying and measuring the cost savings of process improvement initiatives in a Preoperative Assessment Center (PAC). Use TDABC to measure the value of process improvement initiatives that reduce the costs of performing a preoperative assessment while maintaining the quality of the assessment. Apply the principles of TDABC in a PAC to measure the value, from baseline, of two phases of performance improvement initiatives and determine the impact of each implementation in terms of cost, time and efficiency. Through two rounds of performance improvements, we quantified an overall reduction in time spent by patient and personnel of 33% that resulted in a 46% reduction in the costs of providing care in the center. The performance improvements resulted in a 17% decrease in the total number of full time equivalents (FTE's) needed to staff the center and a 19% increase in the numbers of patients assessed in the center. Quality of care, as assessed by the rate of cancellations on the day of surgery, was not adversely impacted by the process improvements. © 2013 Published by Elsevier Inc.

  7. The value of body weight measurement to assess dehydration in children.

    PubMed

    Pruvost, Isabelle; Dubos, François; Chazard, Emmanuel; Hue, Valérie; Duhamel, Alain; Martinot, Alain

    2013-01-01

    Dehydration secondary to gastroenteritis is one of the most common reasons for office visits and hospital admissions. The indicator most commonly used to estimate dehydration status is acute weight loss. Post-illness weight gain is considered as the gold-standard to determine the true level of dehydration and is widely used to estimate weight loss in research. To determine the value of post-illness weight gain as a gold standard for acute dehydration, we conducted a prospective cohort study in which 293 children, aged 1 month to 2 years, with acute diarrhea were followed for 7 days during a 3-year period. The main outcome measures were an accurate pre-illness weight (if available within 8 days before the diarrhea), post-illness weight, and theoretical weight (predicted from the child's individual growth chart). Post-illness weight was measured for 231 (79%) and both theoretical and post-illness weights were obtained for 111 (39%). Only 62 (21%) had an accurate pre-illness weight. The correlation between post-illness and theoretical weight was excellent (0.978), but bootstrapped linear regression analysis showed that post-illness weight underestimated theoretical weight by 0.48 kg (95% CI: 0.06-0.79, p<0.02). The mean difference in the fluid deficit calculated was 4.0% of body weight (95% CI: 3.2-4.7, p<0.0001). Theoretical weight overestimated accurate pre-illness weight by 0.21 kg (95% CI: 0.08-0.34, p = 0.002). Post-illness weight underestimated pre-illness weight by 0.19 kg (95% CI: 0.03-0.36, p = 0.02). The prevalence of 5% dehydration according to post-illness weight (21%) was significantly lower than the prevalence estimated by either theoretical weight (60%) or clinical assessment (66%, p<0.0001).These data suggest that post-illness weight is of little value as a gold standard to determine the true level of dehydration. The performance of dehydration signs or scales determined by using post-illness weight as a gold standard has to be reconsidered.

  8. Seeking Optimal Region-Of-Interest (ROI) Single-Value Summary Measures for fMRI Studies in Imaging Genetics

    PubMed Central

    Tong, Yunxia; Chen, Qiang; Nichols, Thomas E.; Rasetti, Roberta; Callicott, Joseph H.; Berman, Karen F.; Weinberger, Daniel R.; Mattay, Venkata S.

    2016-01-01

    A data-driven hypothesis-free genome-wide association (GWA) approach in imaging genetics studies allows screening the entire genome to discover novel genes that modulate brain structure, chemistry, and function. However, a whole brain voxel-wise analysis approach in such genome-wide based imaging genetic studies can be computationally intense and also likely has low statistical power since a stringent multiple comparisons correction is needed for searching over the entire genome and brain. In imaging genetics with functional magnetic resonance imaging (fMRI) phenotypes, since many experimental paradigms activate focal regions that can be pre-specified based on a priori knowledge, reducing the voxel-wise search to single-value summary measures within a priori ROIs could prove efficient and promising. The goal of this investigation is to evaluate the sensitivity and reliability of different single-value ROI summary measures and provide guidance in future work. Four different fMRI databases were tested and comparisons across different groups (patients with schizophrenia, their siblings, vs. normal control subjects; across genotype groups) were conducted. Our results show that four of these measures, particularly those that represent values from the top most-activated voxels within an ROI are more powerful at reliably detecting group differences and generating greater effect sizes than the others. PMID:26974435

  9. Value in cardiovascular care.

    PubMed

    Bradley, Steven M; Strauss, Craig E; Ho, P Michael

    2017-08-01

    Healthcare value, defined as health outcomes achieved relative to the costs of care, has been proposed as a unifying approach to measure improvements in the quality and affordability of healthcare. Although value is of increasing interest to payers, many providers remain unfamiliar with how value differs from other approaches to the comparison of cost and outcomes (ie, cost-effectiveness analysis). While cost-effectiveness studies can be used by policy makers and payers to inform decisions about coverage and reimbursement for new therapies, the assessment of healthcare can guide improvements in the delivery of healthcare to achieve better outcomes at lower cost. Comparison on value allows for the identification of healthcare delivery organisations or care delivery settings where patient outcomes have been optimised at a lower cost. Gaps remain in the measurement of healthcare value, particularly as it relates to patient-reported health status (symptoms, functional status and health-related quality of life). The use of technology platforms that capture health status measures with minimal disruption to clinical workflow (ie, web portals, automated telephonic systems and tablets to facilitate capture outside of in-person clinical interaction) is facilitating use of health status measures to improve clinical care and optimise patient outcomes. Furthermore, the use of a value framework has catalysed quality improvement efforts and research to seek better patient outcomes at lower cost. © Article author(s) (or their employer(s) unless otherwise stated in the text of the article) 2017. All rights reserved. No commercial use is permitted unless otherwise expressly granted.

  10. Setting the equation: establishing value in spine care.

    PubMed

    Resnick, Daniel K; Tosteson, Anna N A; Groman, Rachel F; Ghogawala, Zoher

    2014-10-15

    Topic review. Describe value measurement in spine care and discuss the motivation for, methods for, and limitations of such measurement. Spinal disorders are common and are an important cause of pain and disability. Numerous complementary and competing treatment strategies are used to treat spinal disorders, and the costs of these treatments is substantial and continue to rise despite clear evidence of improved health status as a result of these expenditures. The authors present the economic and legislative imperatives forcing the assessment of value in spine care. The definition of value in health care and methods to measure value specifically in spine care are presented. Limitations to the utility of value judgments and caveats to their use are presented. Examples of value calculations in spine care are presented and critiqued. Methods to improve and broaden the measurement of value across spine care are suggested, and the role of prospective registries in measuring value is discussed. Value can be measured in spine care through the use of appropriate economic measures and patient-reported outcomes measures. Value must be interpreted in light of the perspective of the assessor, the duration of the assessment period, the degree of appropriate risk stratification, and the relative value of treatment alternatives.

  11. 36 CFR 223.64 - Appraisal on a lump-sum value or rate per unit of measure basis.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... costs or selling values subsequent to the rate redetermination which reduce conversion value to less... or rate per unit of measure basis. 223.64 Section 223.64 Parks, Forests, and Public Property FOREST... Contracts Appraisal and Pricing § 223.64 Appraisal on a lump-sum value or rate per unit of measure basis...

  12. Prognostic value of repeated serum CA 125 measurements in first trimester pregnancy.

    PubMed

    Schmidt, T; Rein, D T; Foth, D; Eibach, H W; Kurbacher, C M; Mallmann, P; Römer, T

    2001-08-01

    To assess the diagnostic value of maternal CA 125 in patients with symptomatic first trimester pregnancy and to evaluate the prognostic significance of CA 125 versus beta-hCG in early pregnancies with intact fetal heartbeat, complicated by vaginal bleeding. Two prospective open-label studies with longitudinal follow-up in the second trial. Academic Department of Obstetrics and Gynecology, University of Cologne. Study 1: 168 patients presenting between gestational weeks 6 and 12 with: extrauterine pregnancy, 29; missed abortion, 50; incomplete spontaneous abortion, 38; imminent abortion, 33; and normal pregnancy (no history of endometriosis or ovarian mass), 18. Study 2: Fifty consecutive patients with vaginal bleeding during gestational weeks 6-12 all of whom having demostrable fetal heartbeat. Eighteen patients finally aborted whereas the remainder had normally continuing pregnancy until term. Study 1: Single serum determinations of CA 125 and beta-hCG were correlated with the different disorders observed. Study 2: Two sequential measurements of serum CA 125 and beta-hCG performed within a 5-7 days interval were related to the outcome of pregnancy as indicated by changes of the ultrasound presentation, miscarriage, future hospitalization, or delivery. Study 1: Patients with vaginal bleeding generally had higher median CA 125 values (38 IU/ml; range 1.3-540) compared to non-bleeding patients (17.8 IU/ml; range 1.0-157). No statistically significant differences in regard to median serum CA 125 levels between symptomatic and normal pregnancies occurred: normal pregnancy, 25.5 IU/ml (range 3.2-97); ectopic pregnancy, 26 IU/ml (range 1.3-157); missed abortion, 19.1IU/ml (range 1-242); threatened abortion, 48 IU/ml (range 5.2-540); spontaneous abortion, 40 IU/ml (range 5.4-442). Study 2: Initial CA 125 levels did not differ significantly between both groups of patients with 27/32 non-aborters and 13/18 aborters showing concentrations below 65 IU/ml. After 5-7 days, CA

  13. The current state of nursing performance measurement, public reporting, and value-based purchasing.

    PubMed

    Kurtzman, Ellen T; Dawson, Ellen M; Johnson, Jean E

    2008-08-01

    Over the last decade, there has been a substantial investment in holding health care providers accountable for the quality of care provided in hospitals and other settings of care. This investment has been realized through the proliferation of national policies that address performance measurement, public reporting, and value-based purchasing. Although nurses represent the largest segment of the health care workforce and despite their acknowledged role in patient safety and health care outcomes, they have been largely absent from policy setting in these areas. This article provides an analysis of current nursing performance measurement and public reporting initiatives and presents a summary of emerging trends in value-based purchasing, with an emphasis on activities in the United States. The article synthesizes issues of relevance to advancing the current climate for nursing quality and concludes with key issues for future policy setting.

  14. Reproducibility, interrater agreement, and age-related changes of fractional anisotropy measures at 3T in healthy subjects: effect of the applied b-value.

    PubMed

    Bisdas, S; Bohning, D E; Besenski, N; Nicholas, J S; Rumboldt, Z

    2008-06-01

    There is no reproducibility study of fractional anisotropy (FA) measurements at 3T using regions of interest (ROIs). Our purpose was to establish the extent and statistical significance of the interrater variability, the variability observed with 2 different b-values, and in 2 separate scanning sessions. Twelve healthy volunteers underwent MR imaging twice. MR imaging was performed on a 3T unit, and FA maps were analyzed independently by 2 observers using ROIs positioned in the corpus callosum, internal capsules, corticospinal tracts, and right thalamus. Changes in FA values (x10(3)) measured with 2 b-values (700 and 1000 s/mm(2)), age-related differences, interobserver agreement, and measurement reproducibility were assessed. In the right internal capsule genu (FA = 702/728; b = 1000/700 s/mm(2)) and the left anterior limb of the internal capsule (AIC; FA = 617/745; b = 1000/700 s/mm(2)), the FA values were significantly different between the 2 b-values (P = .02 and .05, respectively). Significant age-related differences in FA were observed in the genu of the corpus callosum and in the left AIC. Interrater measurements showed fair-to-moderate agreement for most anatomic structures. The lowest significant change for a single subject regarding any FA values between the 2 sessions was in the corpus callosum (4%), whereas the highest one was in the corticospinal tracts (27%). The Bland-Altman plot analysis showed that the 1000-s/mm(2) b-value gave satisfactorily reproducible measurements equally good or better than the 700-s/mm(2) b-value. The reproducibility of FA estimates using ROIs was satisfactory. Measurements with a b-value at 1000 s/mm(2) showed superior reproducibility in most anatomic locations.

  15. A Practical Measure of Student Motivation: Establishing Validity Evidence for the Expectancy-Value-Cost Scale in Middle School

    ERIC Educational Resources Information Center

    Kosovich, Jeff J.; Hulleman, Chris S.; Barron, Kenneth E.; Getty, Steve

    2015-01-01

    We present validity evidence for the Expectancy-Value-Cost (EVC) Scale of student motivation. Using a brief, 10-item scale, we measured middle school students' expectancy, value, and cost for their math and science classes in the Fall and Winter of the same academic year. Confirmatory factor analyses supported the three-factor structure of the EVC…

  16. An evaluation of a new instrument to measure organisational safety culture values and practices.

    PubMed

    Díaz-Cabrera, D; Hernández-Fernaud, E; Isla-Díaz, R

    2007-11-01

    The main aim of this research is to evaluate a safety culture measuring instrument centred upon relevant organisational values and practices related to the safety management system. Seven dimensions that reflect underlying safety meanings are proposed. A second objective is to explore the four cultural orientations in the field of safety arising from the competing values framework. The study sample consisted of 299 participants from five companies in different sectors. The results show six dimensions of organisational values and practices and different company profiles in the organisations studied. The four cultural orientations proposed by the competing values framework are not confirmed. Nevertheless, a coexistence of diverse cultural orientations or paradoxes in the companies is observed.

  17. Using Publicly Available Data to Construct a Transparent Measure of Health Care Value: A Method and Initial Results.

    PubMed

    Weeks, William B; Kotzbauer, Gregory R; Weinstein, James N

    2016-06-01

    Using publicly available Hospital Compare and Medicare data, we found a substantial range of hospital-level performance on quality, expenditure, and value measures for 4 common reasons for admission. Hospitals' ability to consistently deliver high-quality, low-cost care varied across the different reasons for admission. With the exception of coronary artery bypass grafting, hospitals that provided the highest-value care had more beds and a larger average daily census than those providing the lowest-value care. Transparent data like those we present can empower patients to compare hospital performance, make better-informed treatment decisions, and decide where to obtain care for particular health care problems. In the United States, the transition from volume to value dominates discussions of health care reform. While shared decision making might help patients determine whether to get care, transparency in procedure- and hospital-specific value measures would help them determine where to get care. Using Hospital Compare and Medicare expenditure data, we constructed a hospital-level measure of value from a numerator composed of quality-of-care measures (satisfaction, use of timely and effective care, and avoidance of harms) and a denominator composed of risk-adjusted 30-day episode-of-care expenditures for acute myocardial infarction (1,900 hospitals), coronary artery bypass grafting (884 hospitals), colectomy (1,252 hospitals), and hip replacement surgery (1,243 hospitals). We found substantial variation in aggregate measures of quality, cost, and value at the hospital level. Value calculation provided additional richness when compared to assessment based on quality or cost alone: about 50% of hospitals in an extreme quality- (and about 65% more in an extreme cost-) quintile were in the same extreme value quintile. With the exception of coronary artery bypass grafting, higher-value hospitals were larger and had a higher average daily census than lower-value

  18. Quality measures and pediatric radiology: suggestions for the transition to value-based payment.

    PubMed

    Heller, Richard E; Coley, Brian D; Simoneaux, Stephen F; Podberesky, Daniel J; Hernanz-Schulman, Marta; Robertson, Richard L; Donnelly, Lane F

    2017-06-01

    Recent political and economic factors have contributed to a meaningful change in the way that quality in health care, and by extension value, are viewed. While quality is often evaluated on the basis of subjective criteria, pay-for-performance programs that link reimbursement to various measures of quality require use of objective and quantifiable measures. This evolution to value-based payment was accelerated by the 2015 passage of the Medicare Access and CHIP (Children's Health Insurance Program) Reauthorization Act (MACRA). While many of the drivers of these changes are rooted in federal policy and programs such as Medicare and aimed at adult patients, the practice of pediatrics and pediatric radiology will be increasingly impacted. This article addresses issues related to the use of quantitative measures to evaluate the quality of services provided by the pediatric radiology department or sub-specialty section, particularly as seen from the viewpoint of a payer that may be considering ways to link payment to performance. The paper concludes by suggesting a metric categorization strategy to frame future work on the subject.

  19. Quasi-probabilities in conditioned quantum measurement and a geometric/statistical interpretation of Aharonov's weak value

    NASA Astrophysics Data System (ADS)

    Lee, Jaeha; Tsutsui, Izumi

    2017-05-01

    We show that the joint behavior of an arbitrary pair of (generally noncommuting) quantum observables can be described by quasi-probabilities, which are an extended version of the standard probabilities used for describing the outcome of measurement for a single observable. The physical situations that require these quasi-probabilities arise when one considers quantum measurement of an observable conditioned by some other variable, with the notable example being the weak measurement employed to obtain Aharonov's weak value. Specifically, we present a general prescription for the construction of quasi-joint probability (QJP) distributions associated with a given combination of observables. These QJP distributions are introduced in two complementary approaches: one from a bottom-up, strictly operational construction realized by examining the mathematical framework of the conditioned measurement scheme, and the other from a top-down viewpoint realized by applying the results of the spectral theorem for normal operators and their Fourier transforms. It is then revealed that, for a pair of simultaneously measurable observables, the QJP distribution reduces to the unique standard joint probability distribution of the pair, whereas for a noncommuting pair there exists an inherent indefiniteness in the choice of such QJP distributions, admitting a multitude of candidates that may equally be used for describing the joint behavior of the pair. In the course of our argument, we find that the QJP distributions furnish the space of operators in the underlying Hilbert space with their characteristic geometric structures such that the orthogonal projections and inner products of observables can be given statistical interpretations as, respectively, “conditionings” and “correlations”. The weak value Aw for an observable A is then given a geometric/statistical interpretation as either the orthogonal projection of A onto the subspace generated by another observable B, or

  20. The comparability of the universalism value over time and across countries in the European Social Survey: exact vs. approximate measurement invariance

    PubMed Central

    Zercher, Florian; Schmidt, Peter; Cieciuch, Jan; Davidov, Eldad

    2015-01-01

    Over the last decades, large international datasets such as the European Social Survey (ESS), the European Value Study (EVS) and the World Value Survey (WVS) have been collected to compare value means over multiple time points and across many countries. Yet analyzing comparative survey data requires the fulfillment of specific assumptions, i.e., that these values are comparable over time and across countries. Given the large number of groups that can be compared in repeated cross-national datasets, establishing measurement invariance has been, however, considered unrealistic. Indeed, studies which did assess it often failed to establish higher levels of invariance such as scalar invariance. In this paper we first introduce the newly developed approximate approach based on Bayesian structural equation modeling (BSEM) to assess cross-group invariance over countries and time points and contrast the findings with the results from the traditional exact measurement invariance test. BSEM examines whether measurement parameters are approximately (rather than exactly) invariant. We apply BSEM to a subset of items measuring the universalism value from the Portrait Values Questionnaire (PVQ) in the ESS. The invariance of this value is tested simultaneously across 15 ESS countries over six ESS rounds with 173,071 respondents and 90 groups in total. Whereas, the use of the traditional approach only legitimates the comparison of latent means of 37 groups, the Bayesian procedure allows the latent mean comparison of 73 groups. Thus, our empirical application demonstrates for the first time the BSEM test procedure on a particularly large set of groups. PMID:26089811

  1. Transcutaneous oxygen pressure measurement in diabetic foot ulcers: mean values and cut-point for wound healing.

    PubMed

    Yang, Chuan; Weng, Huan; Chen, Lihong; Yang, Haiyun; Luo, Guangming; Mai, Lifang; Jin, Guoshu; Yan, Li

    2013-01-01

    The purpose of this study was to investigate mean values and cut-point of transcutaneous oxygen pressure (TcPO2) measurement in patients with diabetic foot ulcers. Prospective, descriptive study. Sixty-one patients with diabetes mellitus and foot ulcers comprised the sample. The research setting was Sun Yat-sen Memorial Hospital of SunYat-sen University, Guangzhou, China. Participants underwent transcutaneous oxygen (TcPO2) measurement at the dorsum of foot. Patients were classified into 3 groups according to clinical outcomes: (1) ulcers healed with intact skin group, (2) ulcer improved, and (3) ulcer failed to improve. TcPO2 was assessed and cut-points for predicting diabetic foot ulcer healing were calculated. Thirty-six patients healed with intact skin, 8 experienced improvement, and 17 showed no improvement. Mean TcPO2 levels were significantly higher (P< .001) in healed ulcers with intact skin (32 ± 10 mmHg) when compared to the improvement group (30 ± 7 mmHg) and the nonhealing group (15 ± 12 mmHg). All patients with TcPO2≤ 10 mmHg failed to heal or experienced deterioration in their foot ulcers. In contrast, all patients with TcPO2≥ 40 mmHg achieved wound closure. Measurement of TcPO2 in the supine position revealed a cut-point value of 25 mmHg as the best threshold for predicting diabetic foot ulcer healing; the area under the curve using this cut-point was 0.838 (95% confidence interval = 0.700-0.976). The sensitivity, specificity, positive predictive value, and negative predictive value for TxPO2 were 88.6%, 82.4%, 90.7%, and 72.2%, respectively. TcPO2≥ 40 mmHg was associated with diabetic foot ulcer healing, but a TcPO2≤ 10 mmHg was associated with failure of wound healing. We found that a cut-point of 25 mmHg was most predictive of diabetic foot ulcer healing.

  2. Value-based neurosurgery: measuring and reducing the cost of microvascular decompression surgery.

    PubMed

    McLaughlin, Nancy; Upadhyaya, Pooja; Buxey, Farzad; Martin, Neil A

    2014-09-01

    Care providers have put significant effort into optimizing patient safety and quality of care. Value, defined as meaningful outcomes achieved per dollar spent, is emerging as a promising framework to redesign health care. Scarce data exist regarding cost measurement and containment for episodes of neurosurgical care. The authors assessed how cost measurement and strategic containment could be used to optimize the value of delivered care after the implementation and maturation of quality improvement initiatives. A retrospective study of consecutive patients undergoing microvascular decompression was performed. Group 1 comprised patients treated prior to the implementation of quality improvement interventions, and Group 2 consisted of those treated after the implementation and maturation of quality improvement processes. A third group, Group 3, represented a contemporary group studied after the implementation of cost containment interventions targeting the three most expensive activities: pre-incision time in the operating room (OR) and total OR time, intraoperative neuromonitoring (IOM), and bed assignment (and overall length of stay [LOS]). The value of care was assessed for all three groups. Forty-four patients were included in the study. Average preparation time pre-incision decreased from 73 to 65 to 45 minutes in Groups 1, 2, and 3, respectively. The average total OR time and OR cost were 434 minutes and $8513 in Group 1; 348 minutes and $7592 in Group 2; and 407 minutes and $8333 in Group 3. The average cost for IOM, excluding electrode needles, was $1557, $1585, and $1263, respectively, in Groups 1, 2, and 3. Average total cost for bed assignment was $5747, $5198, and $4535, respectively, in Groups 1, 2, and 3. The average total LOS decreased from 3.16 days in Group 1 to 2.14 days in Group 3. Complete relief of or a significant decrease in preoperative symptomatology was achieved in 42 of the 44 patients, respectively. Overall, the average cost of a surgical

  3. Critical micelle concentration values for different surfactants measured with solid-phase microextraction fibers.

    PubMed

    Haftka, Joris J-H; Scherpenisse, Peter; Oetter, Günter; Hodges, Geoff; Eadsforth, Charles V; Kotthoff, Matthias; Hermens, Joop L M

    2016-09-01

    The amphiphilic nature of surfactants drives the formation of micelles at the critical micelle concentration (CMC). Solid-phase microextraction (SPME) fibers were used in the present study to measure CMC values of 12 nonionic, anionic, cationic, and zwitterionic surfactants. The SPME-derived CMC values were compared to values determined using a traditional surface tension method. At the CMC of a surfactant, a break in the relationship between the concentration in SPME fibers and the concentration in water is observed. The CMC values determined with SPME fibers deviated by less than a factor of 3 from values determined with a surface tension method for 7 out of 12 compounds. In addition, the fiber-water sorption isotherms gave information about the sorption mechanism to polyacrylate-coated SPME fibers. A limitation of the SPME method is that CMCs for very hydrophobic cationic surfactants cannot be determined when the cation exchange capacity of the SPME fibers is lower than the CMC value. The advantage of the SPME method over other methods is that CMC values of individual compounds in a mixture can be determined with this method. However, CMC values may be affected by the presence of compounds with other chain lengths in the mixture because of possible mixed micelle formation. Environ Toxicol Chem 2016;35:2173-2181. © 2016 SETAC. © 2016 SETAC.

  4. Evaluating Frameworks That Provide Value Measures for Health Care Interventions.

    PubMed

    Mandelblatt, Jeanne S; Ramsey, Scott D; Lieu, Tracy A; Phelps, Charles E

    2017-02-01

    The recent acceleration of scientific discovery has led to greater choices in health care. New technologies, diagnostic tests, and pharmaceuticals have widely varying impact on patients and populations in terms of benefits, toxicities, and costs, stimulating a resurgence of interest in the creation of frameworks intended to measure value in health. Many of these are offered by providers and/or advocacy organizations with expertise and interest in specific diseases (e.g., cancer and heart disease). To help assess the utility of and the potential biases embedded in these frameworks, we created an evaluation taxonomy with seven basic components: 1) define the purpose; 2) detail the conceptual approach, including perspectives, methods for obtaining preferences of decision makers (e.g., patients), and ability to incorporate multiple dimensions of value; 3) discuss inclusions and exclusions of elements included in the framework, and whether the framework assumes clinical intervention or offers alternatives such as palliative care or watchful waiting; 4) evaluate data sources and their scientific validity; 5) assess the intervention's effect on total costs of treating a defined population; 6) analyze how uncertainty is incorporated; and 7) illuminate possible conflicts of interest among those creating the framework. We apply the taxonomy to four representative value frameworks recently published by professional organizations focused on treatment of cancer and heart disease and on vaccine use. We conclude that each of these efforts has strengths and weaknesses when evaluated using our taxonomy, and suggest pathways to enhance the utility of value-assessing frameworks for policy and clinical decision making. Copyright © 2017 International Society for Pharmacoeconomics and Outcomes Research (ISPOR). Published by Elsevier Inc. All rights reserved.

  5. The Value of Body Weight Measurement to Assess Dehydration in Children

    PubMed Central

    Pruvost, Isabelle; Dubos, François; Chazard, Emmanuel; Hue, Valérie; Duhamel, Alain; Martinot, Alain

    2013-01-01

    Dehydration secondary to gastroenteritis is one of the most common reasons for office visits and hospital admissions. The indicator most commonly used to estimate dehydration status is acute weight loss. Post-illness weight gain is considered as the gold-standard to determine the true level of dehydration and is widely used to estimate weight loss in research. To determine the value of post-illness weight gain as a gold standard for acute dehydration, we conducted a prospective cohort study in which 293 children, aged 1 month to 2 years, with acute diarrhea were followed for 7 days during a 3-year period. The main outcome measures were an accurate pre-illness weight (if available within 8 days before the diarrhea), post-illness weight, and theoretical weight (predicted from the child’s individual growth chart). Post-illness weight was measured for 231 (79%) and both theoretical and post-illness weights were obtained for 111 (39%). Only 62 (21%) had an accurate pre-illness weight. The correlation between post-illness and theoretical weight was excellent (0.978), but bootstrapped linear regression analysis showed that post-illness weight underestimated theoretical weight by 0.48 kg (95% CI: 0.06–0.79, p<0.02). The mean difference in the fluid deficit calculated was 4.0% of body weight (95% CI: 3.2–4.7, p<0.0001). Theoretical weight overestimated accurate pre-illness weight by 0.21 kg (95% CI: 0.08–0.34, p = 0.002). Post-illness weight underestimated pre-illness weight by 0.19 kg (95% CI: 0.03–0.36, p = 0.02). The prevalence of 5% dehydration according to post-illness weight (21%) was significantly lower than the prevalence estimated by either theoretical weight (60%) or clinical assessment (66%, p<0.0001).These data suggest that post-illness weight is of little value as a gold standard to determine the true level of dehydration. The performance of dehydration signs or scales determined by using post-illness weight as a gold standard has to be

  6. Variability in objective and subjective measures affects baseline values in studies of patients with COPD

    PubMed Central

    Ha, Jae Wook; Couper, David J.; O’Neal, Wanda K.; Barr, R. Graham; Bleecker, Eugene R.; Carretta, Elizabeth E.; Cooper, Christopher B.; Doerschuk, Claire M.; Drummond, M Bradley; Han, MeiLan K.; Hansel, Nadia N.; Kim, Victor; Kleerup, Eric C.; Martinez, Fernando J.; Rennard, Stephen I.; Tashkin, Donald; Woodruff, Prescott G.; Paine, Robert; Curtis, Jeffrey L.; Kanner, Richard E.

    2017-01-01

    Rationale Understanding the reliability and repeatability of clinical measurements used in the diagnosis, treatment and monitoring of disease progression is of critical importance across all disciplines of clinical practice and in clinical trials to assess therapeutic efficacy and safety. Objectives Our goal is to understand normal variability for assessing true changes in health status and to more accurately utilize this data to differentiate disease characteristics and outcomes. Methods Our study is the first study designed entirely to establish the repeatability of a large number of instruments utilized for the clinical assessment of COPD in the same subjects over the same period. We utilized SPIROMICS participants (n = 98) that returned to their clinical center within 6 weeks of their baseline visit to repeat complete baseline assessments. Demographics, spirometry, questionnaires, complete blood cell counts (CBC), medical history, and emphysema status by computerized tomography (CT) imaging were obtained. Results Pulmonary function tests (PFTs) were highly repeatable (ICC’s >0.9) but the 6 minute walk (6MW) was less so (ICC = 0.79). Among questionnaires, the Saint George’s Respiratory Questionnaire (SGRQ) was most repeatable. Self-reported clinical features, such as exacerbation history, and features of chronic bronchitis, often produced kappa values <0.6. Reported age at starting smoking and average number of cigarettes smoked were modestly repeatable (kappa = 0.76 and 0.79). Complete blood counts (CBC) variables produced intraclass correlation coefficients (ICC) values between 0.6 and 0.8. Conclusions PFTs were highly repeatable, while subjective measures and subject recall were more variable. Analyses using features with poor repeatability could lead to misclassification and outcome errors. Hence, care should be taken when interpreting change in clinical features based on measures with low repeatability. Efforts to improve repeatability of key clinical

  7. Measuring value for low-acuity care across settings.

    PubMed

    Morgan, Sofie Rahman; Smith, Meaghan A; Pitts, Stephen R; Shesser, Robert; Uscher-Pines, Lori; Ward, Michael J; Pines, Jesse M

    2012-09-01

    Increasing healthcare costs have created an emphasis on improving value, defined as how invested time, money, and resources improve health. The role of emergency departments (EDs) within value-driven health systems is still undetermined. Often questioned is the value of an ED visit for conditions that could be reasonably treated elsewhere such as office-based, urgent, and retail clinics. This paper presents a conceptual approach to assess the value of these low-acuity visits. It adapts an existing analytic model to highlight specific factors that impact key stakeholders' (patients, insurers, and society) assessments of the value of ED-based care compared with care in alternative settings. These factors are presented in 3 equations, 1 for each stakeholder, emphasizing how tangible and intangible benefits of care weigh against direct and indirect costs and how each perspective influences value. Aligning value among groups could allow stakeholders to influence each other and could guide rational change in the delivery of acute medical care for low-acuity conditions.

  8. Mapping from disease-specific measures to health-state utility values in individuals with migraine.

    PubMed

    Gillard, Patrick J; Devine, Beth; Varon, Sepideh F; Liu, Lei; Sullivan, Sean D

    2012-05-01

    The objective of this study was to develop empirical algorithms that estimate health-state utility values from disease-specific quality-of-life scores in individuals with migraine. Data from a cross-sectional, multicountry study were used. Individuals with episodic and chronic migraine were randomly assigned to training or validation samples. Spearman's correlation coefficients between paired EuroQol five-dimensional (EQ-5D) questionnaire utility values and both Headache Impact Test (HIT-6) scores and Migraine-Specific Quality-of-Life Questionnaire version 2.1 (MSQ) domain scores (role restrictive, role preventive, and emotional function) were examined. Regression models were constructed to estimate EQ-5D questionnaire utility values from the HIT-6 score or the MSQ domain scores. Preferred algorithms were confirmed in the validation samples. In episodic migraine, the preferred HIT-6 and MSQ algorithms explained 22% and 25% of the variance (R(2)) in the training samples, respectively, and had similar prediction errors (root mean square errors of 0.30). In chronic migraine, the preferred HIT-6 and MSQ algorithms explained 36% and 45% of the variance in the training samples, respectively, and had similar prediction errors (root mean square errors 0.31 and 0.29). In episodic and chronic migraine, no statistically significant differences were observed between the mean observed and the mean estimated EQ-5D questionnaire utility values for the preferred HIT-6 and MSQ algorithms in the validation samples. The relationship between the EQ-5D questionnaire and the HIT-6 or the MSQ is adequate to use regression equations to estimate EQ-5D questionnaire utility values. The preferred HIT-6 and MSQ algorithms will be useful in estimating health-state utilities in migraine trials in which no preference-based measure is present. Copyright © 2012 International Society for Pharmacoeconomics and Outcomes Research (ISPOR). Published by Elsevier Inc. All rights reserved.

  9. Measurement of 13C chemical shift tensor principal values with a magic-angle turning experiment.

    PubMed

    Hu, J Z; Orendt, A M; Alderman, D W; Pugmire, R J; Ye, C; Grant, D M

    1994-08-01

    The magic-angle turning (MAT) experiment introduced by Gan is developed into a powerful and routine method for measuring the principal values of 13C chemical shift tensors in powdered solids. A large-volume MAT probe with stable rotation frequencies down to 22 Hz is described. A triple-echo MAT pulse sequence is introduced to improve the quality of the two-dimensional baseplane. It is shown that measurements of the principal values of chemical shift tensors in complex compounds can be enhanced by using either short contact times or dipolar dephasing pulse sequences to isolate the powder patterns from protonated or non-protonated carbons, respectively. A model compound, 1,2,3-trimethoxybenzene, is used to demonstrate these techniques, and the 13C principal values in 2,3-dimethylnaphthalene and Pocahontas coal are reported as typical examples.

  10. Liver Stiffness Measured by Two-Dimensional Shear-Wave Elastography: Prognostic Value after Radiofrequency Ablation for Hepatocellular Carcinoma.

    PubMed

    Lee, Dong Ho; Lee, Jeong Min; Yoon, Jung-Hwan; Kim, Yoon Jun; Lee, Jeong-Hoon; Yu, Su Jong; Han, Joon Koo

    2018-03-01

    To evaluate the prognostic value of liver stiffness (LS) measured using two-dimensional (2D) shear-wave elastography (SWE) in patients with hepatocellular carcinoma (HCC) treated by radiofrequency ablation (RFA). The Institutional Review Board approved this retrospective study and informed consent was obtained from all patients. A total of 134 patients with up to 3 HCCs ≤5 cm who had undergone pre-procedural 2D-SWE prior to RFA treatment between January 2012 and December 2013 were enrolled. LS values were measured using real-time 2D-SWE before RFA on the procedural day. After a mean follow-up of 33.8 ± 9.9 months, we analyzed the overall survival after RFA using the Kaplan-Meier method and Cox proportional hazard regression model. The optimal cutoff LS value to predict overall survival was determined using the minimal p value approach. During the follow-up period, 22 patients died, and the estimated 1- and 3-year overall survival rates were 96.4 and 85.8%, respectively. LS measured by 2D-SWE was found to be a significant predictive factor for overall survival after RFA of HCCs, as was the presence of extrahepatic metastases. As for the optimal cutoff LS value for the prediction of overall survival, it was determined to be 13.3 kPa. In our study, 71 patients had LS values ≥13.3 kPa, and the estimated 3-year overall survival was 76.8% compared to 96.3% in 63 patients with LS values <13.3 kPa. This difference was statistically significant (hazard ratio = 4.30 [1.26-14.7]; p = 0.020). LS values measured by 2D-SWE was a significant predictive factor for overall survival after RFA for HCC.

  11. Influence of extraction solvent on antioxidant capacity value of oleaster measured by ORAC method.

    PubMed

    Yalcin, Gorkem; Sogut, Ozlem

    2014-01-01

    Oxygen radical absorbance capacity (ORAC) is a widely used hydrogen atom transfer-based method which measures the antioxidant capacity of natural products. ORAC values of oleaster (Elaeagnus angustifolia L.), which was extracted with ethanol/acetone (7:3, v/v), ethanol/water (1:1, v/v) and methanol/water (1:1, v/v) in order to evaluate the effects of solvent type on antioxidant capacity, were examined. In general, results revealed that ethanol/water extracts exhibited better antioxidant capacity values. Furthermore, results obtained by using ORAC-eosin y (ORAC-EY), one of the widely used derivative of fluorescein (FL), as a fluorescent probe were compared with those obtained by using ORAC-FL. According to the results, ORAC-EY values were found to be compatible with ORAC-FL values.

  12. A quantum inspired model of radar range and range-rate measurements with applications to weak value measurements

    NASA Astrophysics Data System (ADS)

    Escalante, George

    2017-05-01

    Weak Value Measurements (WVMs) with pre- and post-selected quantum mechanical ensembles were proposed by Aharonov, Albert, and Vaidman in 1988 and have found numerous applications in both theoretical and applied physics. In the field of precision metrology, WVM techniques have been demonstrated and proven valuable as a means to shift, amplify, and detect signals and to make precise measurements of small effects in both quantum and classical systems, including: particle spin, the Spin-Hall effect of light, optical beam deflections, frequency shifts, field gradients, and many others. In principal, WVM amplification techniques are also possible in radar and could be a valuable tool for precision measurements. However, relatively limited research has been done in this area. This article presents a quantum-inspired model of radar range and range-rate measurements of arbitrary strength, including standard and pre- and post-selected measurements. The model is used to extend WVM amplification theory to radar, with the receive filter performing the post-selection role. It is shown that the description of range and range-rate measurements based on the quantum-mechanical measurement model and formalism produces the same results as the conventional approach used in radar based on signal processing and filtering of the reflected signal at the radar receiver. Numerical simulation results using simple point scatterrer configurations are presented, applying the quantum-inspired model of radar range and range-rate measurements that occur in the weak measurement regime. Potential applications and benefits of the quantum inspired approach to radar measurements are presented, including improved range and Doppler measurement resolution.

  13. Partial discharge measurements on 110kV current transformers. Setting the control value. Case study

    NASA Astrophysics Data System (ADS)

    Dan, C.; Morar, R.

    2017-05-01

    The case study presents a series of partial discharge measurements, reflecting the state of insulation of 110kV CURRENT TRANSFORMERS located in Sibiu county substations. Measurements were performed based on electrical method, using MPD600: an acquisition and analysis toolkit for detecting, recording, and analyzing partial discharges. MPD600 consists of one acquisition unit, an optical interface and a computer with dedicated software. The system allows measurements of partial discharge on site, even in presence of strong electromagnetic interferences because it provides synchronous acquisition from all measurement points. Therefore, measurements, with the ability to be calibrated, do render: - a value subject to interpretation according to IEC 61869-1:2007 + IEC 61869-2:2012 + IEC 61869-3:2011 + IEC 61869-5:2011 and IEC 60270: 2000; - the possibility to determine the quantitative limit of PD (a certain control value) to which the equipment can be operated safely and repaired with minimal costs (relative to the high costs implied by eliminating the consequences of a failure) identified empirically (process in which the instrument transformer subjected to the tests was completely destroyed).

  14. What Is the Value of Value-Based Purchasing?

    PubMed

    Tanenbaum, Sandra J

    2016-10-01

    Value-based purchasing (VBP) is a widely favored strategy for improving the US health care system. The meaning of value that predominates in VBP schemes is (1) conformance to selected process and/or outcome metrics, and sometimes (2) such conformance at the lowest possible cost. In other words, VBP schemes choose some number of "quality indicators" and financially incent providers to meet them (and not others). Process measures are usually based on clinical science that cannot determine the effects of a process on individual patients or patients with comorbidities, and do not necessarily measure effects that patients value; additionally, there is no provision for different patients valuing different things. Proximate outcome measures may or may not predict distal ones, and the more distal the outcome, the less reliably it can be attributed to health care. Outcome measures may be quite rudimentary, such as mortality rates, or highly contestable: survival or function after prostate surgery? When cost is an element of value-based purchasing, it is the cost to the value-based payer and not to other payers or patients' families. The greatest value of value-based purchasing may not be to patients or even payers, but to policy makers seeking a morally justifiable alternative to politically contested regulatory policies. Copyright © 2016 by Duke University Press.

  15. Measuring Staff Perceptions of University Identity and Activities: The Mission and Values Inventory

    ERIC Educational Resources Information Center

    Ferrari, Joseph R.; Velcoff, Jessica

    2006-01-01

    Higher education institutions need to ascertain whether their stakeholders understand the school's mission, vision, and values. In the present study, the psychometric properties of a mission identity and activity measure were investigated with two staff samples. Using a principal component factor analysis (varimax rotation), respondents in Sample…

  16. Correlation between environmental relative moldiness index (ERMI) values in French dwellings and other measures of fungal contamination

    EPA Science Inventory

    The Environmental Relative Moldiness Index (ERMI) is a DNA-based metric developed to describe the fungal contamination in US dwellings. Our goal was to determine if the ERMI values in dwellings in north western France were correlated with other measures of fungal contamination. D...

  17. Looking Under the Streetlight? A Framework for Differentiating Performance Measures by Level of Care in a Value-Based Payment Environment

    PubMed Central

    Van Such, Monica B.; Nesse, Robert E.; Dilling, James A.; Swensen, Stephen J.; Thompson, Kristine M.; Orlowski, Janis M.; Santrach, Paula J.

    2017-01-01

    The majority of quality measures used to assess providers and hospitals are based on easily obtained data, focused on a few dimensions of quality, and developed mainly for primary/community care and population health. While this approach supports efforts focused on addressing the triple aim of health care, many current quality report cards and assessments do not reflect the breadth or complexity of many referral center practices. In this article, the authors highlight the differences between population health efforts and referral care and address issues related to value measurement and performance assessment. They discuss why measures may need to differ across the three levels of care (primary/community care, secondary care, complex care) and illustrate the need for further risk adjustment to eliminate referral bias. With continued movement toward value-based purchasing, performance measures and reimbursement schemes need to reflect the increased level of intensity required to provide complex care. The authors propose a framework to operationalize value measurement and payment for specialty care, and they make specific recommendations to improve performance measurement for complex patients. Implementing such a framework to differentiate performance measures by level of care involves coordinated efforts to change both policy and operational platforms. An essential component of this framework is a new model that defines the characteristics of patients who require complex care and standardizes metrics that incorporate those definitions. PMID:28353502

  18. Looking Under the Streetlight? A Framework for Differentiating Performance Measures by Level of Care in a Value-Based Payment Environment.

    PubMed

    Naessens, James M; Van Such, Monica B; Nesse, Robert E; Dilling, James A; Swensen, Stephen J; Thompson, Kristine M; Orlowski, Janis M; Santrach, Paula J

    2017-07-01

    The majority of quality measures used to assess providers and hospitals are based on easily obtained data, focused on a few dimensions of quality, and developed mainly for primary/community care and population health. While this approach supports efforts focused on addressing the triple aim of health care, many current quality report cards and assessments do not reflect the breadth or complexity of many referral center practices.In this article, the authors highlight the differences between population health efforts and referral care and address issues related to value measurement and performance assessment. They discuss why measures may need to differ across the three levels of care (primary/community care, secondary care, complex care) and illustrate the need for further risk adjustment to eliminate referral bias.With continued movement toward value-based purchasing, performance measures and reimbursement schemes need to reflect the increased level of intensity required to provide complex care. The authors propose a framework to operationalize value measurement and payment for specialty care, and they make specific recommendations to improve performance measurement for complex patients. Implementing such a framework to differentiate performance measures by level of care involves coordinated efforts to change both policy and operational platforms. An essential component of this framework is a new model that defines the characteristics of patients who require complex care and standardizes metrics that incorporate those definitions.

  19. Value of F-wave inversion in diagnosis of carpal tunnel syndrome and it's relation with anthropometric measurements.

    PubMed

    Komurcu, Hatice Ferhan; Kilic, Selim; Anlar, Omer

    2015-01-01

    The clinical importance of F-wave inversion in the diagnosis of Carpal Tunnel Syndrome (CTS) is not yet well known. This study aims to investigate the value of F-wave inversion in diagnosing CTS, and to evaluate the relationship of F-wave inversion with age, gender, diabetes mellitus, body mass index (BMI), wrist or waist circumferences. Patients (n=744) who were considered to have CTS with clinical findings were included in the study. In order to confirm the diagnosis of CTS, standard electrophysiological parameters were studied with electroneuromyography. In addition, median nerve F-wave measurements were done and we determined if F-wave inversion was present or not. Sensitivity and specificity of F-wave inversion were investigated for its value in showing CTS diagnosed by electrophysiological examination. CTS diagnosis was confirmed by routine electrophysiological parameters in 307 (41.3%) patients. The number of the patients with the presence of F-wave inversion was 243 (32.7%). Sensitivity of F-wave inversion was found as 56% and specificity as 83.8%. BMI and wrist circumference values were significantly higher in patients with F-wave inversion present than those with F-wave inversion absent (p=0.0033, p=0.025 respectively). F-wave inversion can be considered as a valuable electrophysiological measurement for screening of CTS.

  20. Minimal sufficient positive-operator valued measure on a separable Hilbert space

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Kuramochi, Yui, E-mail: kuramochi.yui.22c@st.kyoto-u.ac.jp

    We introduce a concept of a minimal sufficient positive-operator valued measure (POVM), which is the least redundant POVM among the POVMs that have the equivalent information about the measured quantum system. Assuming the system Hilbert space to be separable, we show that for a given POVM, a sufficient statistic called a Lehmann-Scheffé-Bahadur statistic induces a minimal sufficient POVM. We also show that every POVM has an equivalent minimal sufficient POVM and that such a minimal sufficient POVM is unique up to relabeling neglecting null sets. We apply these results to discrete POVMs and information conservation conditions proposed by the author.

  1. A comparison between probability and information measures of uncertainty in a simulated soil map and the economic value of imperfect soil information.

    NASA Astrophysics Data System (ADS)

    Lark, R. Murray

    2014-05-01

    Conventionally the uncertainty of a conventional soil map has been expressed in terms of the mean purity of its map units: the probability that the soil profile class examined at a site would be found to correspond to the eponymous class of the simple map unit that is delineated there (Burrough et al, 1971). This measure of uncertainty has an intuitive meaning and is used for quality control in soil survey contracts (Western, 1978). However, it may be of limited value to the manager or policy maker who wants to decide whether the map provides a basis for decision making, and whether the cost of producing a better map would be justified. In this study I extend a published analysis of the economic implications of uncertainty in a soil map (Giasson et al., 2000). A decision analysis was developed to assess the economic value of imperfect soil map information for agricultural land use planning. Random error matrices for the soil map units were then generated, subject to constraints which ensure consistency with fixed frequencies of the different soil classes. For each error matrix the mean map unit purity was computed, and the value of the implied imperfect soil information was computed by the decision analysis. An alternative measure of the uncertainty in a soil map was considered. This is the mean soil map information which is the difference between the information content of a soil observation, at a random location in the region, and the information content of a soil observation given that the map unit is known. I examined the relationship between the value of imperfect soil information and the purity and information measures of map uncertainty. In both cases there was considerable variation in the economic value of possible maps with fixed values of the uncertainty measure. However, the correlation was somewhat stronger with the information measure, and there was a clear upper bound on the value of an imperfect soil map when the mean information takes some

  2. Measuring Striving for Understanding and Learning Value of Geometry: A Validity Study

    ERIC Educational Resources Information Center

    Ubuz, Behiye; Aydinyer, Yurdagül

    2017-01-01

    The current study aimed to construct a questionnaire that measures students' personality traits related to "striving for understanding" and "learning value of geometry" and then examine its psychometric properties. Through the use of multiple methods on two independent samples of 402 and 521 middle school students, two studies…

  3. Achieving Value in Primary Care: The Primary Care Value Model.

    PubMed

    Rollow, William; Cucchiara, Peter

    2016-03-01

    The patient-centered medical home (PCMH) model provides a compelling vision for primary care transformation, but studies of its impact have used insufficiently patient-centered metrics with inconsistent results. We propose a framework for defining patient-centered value and a new model for value-based primary care transformation: the primary care value model (PCVM). We advocate for use of patient-centered value when measuring the impact of primary care transformation, recognition, and performance-based payment; for financial support and research and development to better define primary care value-creating activities and their implementation; and for use of the model to support primary care organizations in transformation. © 2016 Annals of Family Medicine, Inc.

  4. Theoretical value of Newtonian constant G confirmed by the International Bureau of Weights & Measures in Paris, France

    NASA Astrophysics Data System (ADS)

    Omerbashich, Mensur

    2015-01-01

    World oldest authority for scientific constants and the keeper of the original metre standard, the International Bureau of Weights and Measures (BIPM) in Paris, France has accomplished a historic confirmation of the Omerbashich's (first-ever) scientific prediction of value of the Newtonian gravitational constant G.

  5. Relevance of methods and standards for the assessment of measurement system performance in a High-Value Manufacturing Industry

    NASA Astrophysics Data System (ADS)

    Loftus, Pete; Giudice, Seb

    2014-08-01

    Measurements underpin the engineering decisions that allow products to be designed, manufactured, operated, and maintained. Therefore, the quality of measured data needs to be systematically assured to allow decision makers to proceed with confidence. The use of standards is one way of achieving this. This paper explores the relevance of international documentary standards to the assessment of measurement system capability in High Value Manufacturing (HVM) Industry. An internal measurement standard is presented which supplements these standards and recommendations are made for a cohesive effort to develop the international standards to provide consistency in such industrial applications.

  6. Measuring striving for understanding and learning value of geometry: a validity study

    NASA Astrophysics Data System (ADS)

    Ubuz, Behiye; Aydınyer, Yurdagül

    2017-11-01

    The current study aimed to construct a questionnaire that measures students' personality traits related to striving for understanding and learning value of geometry and then examine its psychometric properties. Through the use of multiple methods on two independent samples of 402 and 521 middle school students, two studies were performed to address this issue to provide support for its validity. In Study 1, exploratory factor analysis indicated the two-factor model. In Study 2, confirmatory factor analysis indicated the better fit of two-factor model compared to one or three-factor model. Convergent and discriminant validity evidence provided insight into the distinctiveness of the two factors. Subgroup validity evidence revealed gender differences for striving for understanding geometry trait favouring girls and grade level differences for learning value of geometry trait favouring the sixth- and seventh-grade students. Predictive validity evidence demonstrated that the striving for understanding geometry trait but not learning value of geometry trait was significantly correlated with prior mathematics achievement. In both studies, each factor and the entire questionnaire showed satisfactory reliability. In conclusion, the questionnaire was psychometrically sound.

  7. Measuring the economic value of wildlife: a caution

    Treesearch

    T. H. Stevens

    1992-01-01

    Wildlife values appear to be very sensitive to whether species are evaluated separately or together, and value estimates often seem inconsistent with neoclassical economic theory. Wildlife value estimates must therefore be used with caution. Additional research about the nature of individual value structures for wildlife is needed.

  8. Measurement of utility values in the UK for health states related to immune thrombocytopenic purpura.

    PubMed

    Szende, Agota; Brazier, John; Schaefer, Caroline; Deuson, Robert; Isitt, John J; Vyas, Paresh

    2010-08-01

    To measure utility values associated with immune (idiopathic) thrombocytopenic purpura (ITP), as perceived by the United Kingdom (UK) general public. A multi-step process, including clinical trial data, literature review, and patient focus group, was used to develop ITP health states valued in a web survey. Six ITP health states were defined based on platelet levels, risk of bleeding and key adverse events/disease complications. Clinical trial data on bleeding and ITP-specific quality of life data were key sources for developing health-state descriptions. 359 respondents, randomly selected from a managed web panel in the UK, completed the web-based Time Trade-Off survey. Wilcoxon signed-rank test was used to compare differences between each pair of health states. Sample characteristics (mean age: 47.9 +/- 16.9 years; 54% female) were comparable to the UK general population. ITP health states were valued as significantly worse than perfect health. Experiencing bleeding episodes was a more important driver than low platelet levels in valuing a health state to be worse. Substantial disutilities were associated with surviving an intracranial haemorrhage. Mean (SD) utility values for each ITP health state are: HS1: platelets >or=50 x 10(9)/L, no outpatient bleed: 0.863 +/- 0.15; HS2: platelets >or=50 x 10(9)/L, outpatient bleed: 0.734 +/- 0.19; HS3: platelets <50 x 10(9)/L, no outpatient bleed: 0.841 +/- 0.19; HS4: platelets <50 x 10(9)/L, outpatient bleed: 0.732 +/- 0.19; HS5: intracranial haemorrhage (2-6 months): 0.038 +/- 0.46; HS6: steroid treatment adverse events: 0.758 +/- 0.20. Potential limitations relate to web user population characteristics and lack of comparative testing of web-based TTO methods. Results provide evidence that the UK general population associate substantial loss of value living with ITP, suggesting an important role for new ITP treatments. Utility values based on these health states may be useful in future cost-effectiveness studies of

  9. Determinination of plasma osmolality and agreement between measured and calculated values in healthy adult Hispaniolan Amazon parrots (Amazona ventralis).

    PubMed

    Acierno, Mark J; Mitchell, Mark A; Freeman, Diana M; Schuster, Patricia J; Guzman, David Sanchez-Migallon; Tully, Thomas N

    2009-09-01

    To determine plasma osmolality in healthy adult Hispaniolan Amazon parrots (Amazona ventralis) and validate osmolality equations in these parrots. 20 healthy adult Hispaniolan Amazon parrots. A blood sample (0.5 mL) was collected from the right jugular vein of each parrot and placed into a lithium heparin microtainer tube. Samples were centrifuged, and plasma was harvested and frozen at -30 degrees C. Samples were thawed, and plasma osmolality was measured in duplicate with a freezing-point depression osmometer. The mean value was calculated for the 2 osmolality measurements. Plasma osmolality values were normally distributed, with a mean +/- SD of 326.0 +/- 6.878 mOsm/kg. The equations (2 x [Na(+) + K(+)]) + (glucose/18), which resulted in bias of 2.3333 mOsm/kg and limits of agreement of -7.0940 to 11.7606 mOsm/kg, and (2 x [Na(+) + K(+)]) + (uric acid concentration/16.8) + (glucose concentration/18), which resulted in bias of 5.8117 mOsm/kg and limits of agreement of -14.6640 to 3.0406 mOsm/kg, yielded calculated values that were in good agreement with the measured osmolality. IV administration of large amounts of hypotonic fluids can have catastrophic consequences. Osmolality of the plasma from parrots in this study was significantly higher than that of commercially available prepackaged fluids. Therefore, such fluids should be used with caution in Hispaniolan Amazon parrots as well as other psittacines. Additional studies are needed to determine whether the estimation of osmolality has the same clinical value in psittacines as it does in other animals.

  10. Estimating Time-Varying PCB Exposures Using Person-Specific Predictions to Supplement Measured Values: A Comparison of Observed and Predicted Values in Two Cohorts of Norwegian Women

    PubMed Central

    Nøst, Therese Haugdahl; Breivik, Knut; Wania, Frank; Rylander, Charlotta; Odland, Jon Øyvind; Sandanger, Torkjel Manning

    2015-01-01

    , Rylander C, Odland JØ, Sandanger TM. 2016. Estimating time-varying PCB exposures using person-specific predictions to supplement measured values: a comparison of observed and predicted values in two cohorts of Norwegian women. Environ Health Perspect 124:299–305; http://dx.doi.org/10.1289/ehp.1409191 PMID:26186800

  11. Improved Correction of IR Loss in Diffuse Shortwave Measurements: An ARM Value-Added Product

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Younkin, K; Long, CN

    Simple single black detector pyranometers, such as the Eppley Precision Spectral Pyranometer (PSP) used by the Atmospheric Radiation Measurement (ARM) Program, are known to lose energy via infrared (IR) emission to the sky. This is especially a problem when making clear-sky diffuse shortwave (SW) measurements, which are inherently of low magnitude and suffer the greatest IR loss. Dutton et al. (2001) proposed a technique using information from collocated pyrgeometers to help compensate for this IR loss. The technique uses an empirically derived relationship between the pyrgeometer detector data (and alternatively the detector data plus the difference between the pyrgeometer casemore » and dome temperatures) and the nighttime pyranometer IR loss data. This relationship is then used to apply a correction to the diffuse SW data during daylight hours. We developed an ARM value-added product (VAP) called the SW DIFF CORR 1DUTT VAP to apply the Dutton et al. correction technique to ARM PSP diffuse SW measurements.« less

  12. E/N effects on K0 values revealed by high precision measurements under low field conditions

    NASA Astrophysics Data System (ADS)

    Hauck, Brian C.; Siems, William F.; Harden, Charles S.; McHugh, Vincent M.; Hill, Herbert H.

    2016-07-01

    Ion mobility spectrometry (IMS) is used to detect chemical warfare agents, explosives, and narcotics. While IMS has a low rate of false positives, their occurrence causes the loss of time and money as the alarm is verified. Because numerous variables affect the reduced mobility (K0) of an ion, wide detection windows are required in order to ensure a low false negative response rate. Wide detection windows, however, reduce response selectivity, and interferents with similar K0 values may be mistaken for targeted compounds and trigger a false positive alarm. Detection windows could be narrowed if reference K0 values were accurately known for specific instrumental conditions. Unfortunately, there is a lack of confidence in the literature values due to discrepancies in the reported K0 values and their lack of reported error. This creates the need for the accurate control and measurement of each variable affecting ion mobility, as well as for a central accurate IMS database for reference and calibration. A new ion mobility spectrometer has been built that reduces the error of measurements affecting K0 by an order of magnitude less than ±0.2%. Precise measurements of ±0.002 cm2 V-1 s-1 or better have been produced and, as a result, an unexpected relationship between K0 and the electric field to number density ratio (E/N) has been discovered in which the K0 values of ions decreased as a function of E/N along a second degree polynomial trend line towards an apparent asymptote at approximately 4 Td.

  13. TH-CD-207B-10: Effect of CT Reconstruction Filter On Measured Hounsfield Values in Lung Nodules

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Little, K; Reiser, I; Sanchez, A

    Purpose: Measured Hounsfield numbers in CT are used by radiologists to determine the presence of calcium or fat in lung nodules, either of which suggests a benign diagnosis. However, substantial variations in Hounsfield number may arise due to the use of different reconstruction parameters such as the filter/kernel, leading to measurement inaccuracies. This quality improvement project was developed to demonstrate measurement pitfalls and to identify acceptable conditions for incorporating Hounsfield values as a factor in lung nodule diagnosis. Methods: 12 mm-diameter spheres of polyurethane and urethane foam were placed into an anthropomorphic chest phantom, and 10 mm-diameter tubes with varyingmore » iodine concentrations were placed into a 16 cm PMMA cylindrical phantom. Additionally, 11 mm-diameter PMMA and HDPE spheres were placed in a 10 cm PMMA cylindrical phantom. Phantoms were scanned at 120 kVp using a Siemens Biograph mCT and on a Philips iCT and reconstructed using various reconstruction filters. Results: For the Siemens system, both sharp kernels and smooth kernels altered the Hounsfield numbers. Hounsfield numbers varied within a range of 8.9 HU for urethane foam and varied within 58.7 HU for polyurethane. The iodine measurements varied up to 37.9 HU for the lowest concentration. For the Philips system, Hounsfield numbers were relatively consistent but were higher for the “Detail” and “Lung Enhanced” filters, varying by 36.9 HU for PMMA and 15.9 HU for HDPE. Conclusion: Reconstruction filters can change the measured Hounsfield numbers of nodular objects, especially with detail-enhancing (sharpening) filters commonly used in lung imaging. Measured values should only be used for diagnostic decision support with filters that have demonstrated accuracy and consistency. While filter accuracy statements are available from manufacturers, radiologists are likely not aware of the extent of potential variations that can occur in a clinical setting.« less

  14. What Value "Value Added"?

    ERIC Educational Resources Information Center

    Richards, Andrew

    2015-01-01

    Two quantitative measures of school performance are currently used, the average points score (APS) at Key Stage 2 and value-added (VA), which measures the rate of academic improvement between Key Stage 1 and 2. These figures are used by parents and the Office for Standards in Education to make judgements and comparisons. However, simple…

  15. Sentinels Guarding the Grail: Value-Added Measurement and the Quest for Education Reform

    ERIC Educational Resources Information Center

    Gabriel, Rachael; Lester, Jessica Nina

    2013-01-01

    Since the beginning of the federal Race To The Top grant competition, Value-Added Measurement (VAM) has captured the attention of the American public through high-profile media representations of the tool and the controversy that surrounds it. In this paper, we build upon investigations of constructions of VAM in the media and present a discourse…

  16. Realising the Real Benefits of Outsourcing: Measurement Excellence and Its Importance in Achieving Long Term Value

    NASA Astrophysics Data System (ADS)

    Oshri, Ilan; Kotlarsky, Julia

    These days firms are, more than ever, pressed to demonstrate returns on their investment in outsourcing. While the initial returns can always be associated with one-off cost cutting, outsourcing arrangements are complex, often involving inter-related high-value activities, which makes the realisation of long-term benefits from outsourcing ever more challenging. Executives in client firms are no longer satisfied with the same level of service delivery through the outsourcing lifecycle. They seek to achieve business transformation and innovation in their present and future services, beyond satisfying service level agreements (SLAs). Clearly the business world is facing a new challenge: an outsourcing delivery system of high-value activities that demonstrates value over time and across business functions. However, despite such expectations, many client firms are in the dark when trying to measure and quantify the return on outsourcing investments: results of this research show that less than half of all CIOs and CFOs (43%) have attempted to calculate the financial impact of outsourcing to their bottom line, indicating that the financial benefits are difficult to quantify (51%).

  17. Anomalous weak values and the violation of a multiple-measurement Leggett-Garg inequality

    NASA Astrophysics Data System (ADS)

    Avella, Alessio; Piacentini, Fabrizio; Borsarelli, Michelangelo; Barbieri, Marco; Gramegna, Marco; Lussana, Rudi; Villa, Federica; Tosi, Alberto; Degiovanni, Ivo Pietro; Genovese, Marco

    2017-11-01

    Quantum mechanics presents peculiar properties that, on the one hand, have been the subject of several theoretical and experimental studies about its very foundations and, on the other hand, provide tools for developing new technologies, the so-called quantum technologies. The nonclassicality pointed out by Leggett-Garg inequalities has represented, with Bell inequalities, one of the most investigated subjects. In this article we study the connection of Leggett-Garg inequalities with a new emerging field of quantum measurement, the weak values in the case of a series of sequential measurements on a single object. In detail, we perform an experimental study of the four-time-correlator Leggett-Garg test, by exploiting single and sequential weak measurements performed on heralded single photons.

  18. Prognostic value of cardiovascular magnetic resonance imaging measurements corrected for age and sex in idiopathic pulmonary arterial hypertension.

    PubMed

    Swift, Andrew J; Rajaram, Smitha; Campbell, Michael J; Hurdman, Judith; Thomas, Steve; Capener, Dave; Elliot, Charlie; Condliffe, Robin; Wild, Jim M; Kiely, David G

    2014-01-01

    There are limited data on the prognostic value of cardiovascular magnetic resonance measurements in idiopathic pulmonary arterial hypertension, with no studies investigating the impact of correction of cardiovascular magnetic resonance indices for age and sex on prognostic value. Consecutive patients with idiopathic pulmonary arterial hypertension underwent cardiovascular magnetic resonance imaging at 1.5T. Steady-state free precession cardiac volumes and mass measurements were corrected for age, sex, and body surface area according to reference data and prognostic significance assessed. A total of 80 patients with idiopathic pulmonary arterial hypertension were identified, and 23 patients died during the mean follow-up of 32±14 months. Corrected for age, sex, and body surface area, right ventricular end-systolic volume (P=0.004) strongly predicted mortality, independent of World Health Organization functional class, mean right atrial pressure, cardiac index, and mixed venous oxygen saturations. Consideration should be given to correcting cardiovascular magnetic resonance measures for age, sex, and body surface area, particularly given the changing demographics of patients with idiopathic pulmonary arterial hypertension. Corrected right ventricular end-systolic volume is a strong prognostic marker in idiopathic pulmonary arterial hypertension, independent of invasively derived measurements, mean right atrial pressure cardiac index, and mixed venous oxygen saturations.

  19. Value Added?

    ERIC Educational Resources Information Center

    UCLA IDEA, 2012

    2012-01-01

    Value added measures (VAM) uses changes in student test scores to determine how much "value" an individual teacher has "added" to student growth during the school year. Some policymakers, school districts, and educational advocates have applauded VAM as a straightforward measure of teacher effectiveness: the better a teacher,…

  20. The relationship of live animal muscular and skeletal scores, ultrasound measurements and carcass classification scores with carcass composition and value in steers.

    PubMed

    Conroy, S B; Drennan, M J; Kenny, D A; McGee, M

    2009-11-01

    This study examined the relationship of muscular and skeletal scores and ultrasound measurements in the live animal, and carcass conformation and fat scores with carcass composition and value using 336 steers, slaughtered at 2 years of age. Live animal scores and measurements were recorded at 8 to 12 months of age and pre-slaughter. Following slaughter, each carcass was classified for conformation and fatness and the right side dissected into meat, fat and bone. Carcass conformation scores and fat scores were both measured on a continuous 15-point scale and ranged from 2.0 to 12.0 and from 2.8 to 13.3, respectively. Pre-slaughter muscular scores showed positive correlations (P < 0.001) ranging from 0.31 to 0.86 with carcass meat proportion, proportion of high-value cuts in the carcass, conformation score and carcass value, significant negative correlations with carcass fat (r = -0.13) and bone (r = -0.81) proportions, and generally low non-significant relationships with the proportion of high-value cuts in meat and carcass fat score. Pre-slaughter ultrasound muscle depth and carcass conformation score showed similar correlations with carcass traits to those using the pre-slaughter muscular scoring procedure. Pre-slaughter ultrasound fat depth showed positive correlations (P < 0.001) with carcass fat proportion (r = 0.59) and fat score (r = 0.63), and significant negative correlations (-0.23 to -0.50) with carcass meat and bone proportions, high-value cuts in the carcass and in meat, and carcass value. Pre-slaughter skeletal scores generally showed poor correlations ranging from -0.38 to 0.52 with the various carcass traits. Corresponding correlations (-0.26 to 0.44) involving records collected at 8 to 12 months of age were lower than those using pre-slaughter records. A one-unit increase in carcass conformation score increased carcass meat proportion and value by 11.2 g/kg and 5.6 cents/kg, respectively. Corresponding values for fat score were -8.2 g/kg and -5

  1. Measuring Strategic Value-Drivers for Managing Intellectual Capital

    ERIC Educational Resources Information Center

    Bose, S.; Oh, K. B.

    2004-01-01

    In an evolving business environment characterised by globalisation and a challenging competitive paradigm, it is imperative for strategic management processes to focus on the financial perspectives of value and risk in intellectual capital to create sustainability in long-term value. This paper presents the key issues pertaining to the strategic…

  2. Different top-down approaches to estimate measurement uncertainty of whole blood tacrolimus mass concentration values.

    PubMed

    Rigo-Bonnin, Raül; Blanco-Font, Aurora; Canalias, Francesca

    2018-05-08

    Values of mass concentration of tacrolimus in whole blood are commonly used by the clinicians for monitoring the status of a transplant patient and for checking whether the administered dose of tacrolimus is effective. So, clinical laboratories must provide results as accurately as possible. Measurement uncertainty can allow ensuring reliability of these results. The aim of this study was to estimate measurement uncertainty of whole blood mass concentration tacrolimus values obtained by UHPLC-MS/MS using two top-down approaches: the single laboratory validation approach and the proficiency testing approach. For the single laboratory validation approach, we estimated the uncertainties associated to the intermediate imprecision (using long-term internal quality control data) and the bias (utilizing a certified reference material). Next, we combined them together with the uncertainties related to the calibrators-assigned values to obtain a combined uncertainty for, finally, to calculate the expanded uncertainty. For the proficiency testing approach, the uncertainty was estimated in a similar way that the single laboratory validation approach but considering data from internal and external quality control schemes to estimate the uncertainty related to the bias. The estimated expanded uncertainty for single laboratory validation, proficiency testing using internal and external quality control schemes were 11.8%, 13.2%, and 13.0%, respectively. After performing the two top-down approaches, we observed that their uncertainty results were quite similar. This fact would confirm that either two approaches could be used to estimate the measurement uncertainty of whole blood mass concentration tacrolimus values in clinical laboratories. Copyright © 2018 The Canadian Society of Clinical Chemists. Published by Elsevier Inc. All rights reserved.

  3. Lumbar lordosis and sacral slope in lumbar spinal stenosis: standard values and measurement accuracy.

    PubMed

    Bredow, J; Oppermann, J; Scheyerer, M J; Gundlfinger, K; Neiss, W F; Budde, S; Floerkemeier, T; Eysel, P; Beyer, F

    2015-05-01

    Radiological study. To asses standard values, intra- and interobserver reliability and reproducibility of sacral slope (SS) and lumbar lordosis (LL) and the correlation of these parameters in patients with lumbar spinal stenosis (LSS). Anteroposterior and lateral X-rays of the lumbar spine of 102 patients with LSS were included in this retrospective, radiologic study. Measurements of SS and LL were carried out by five examiners. Intraobserver correlation and correlation between LL and SS were calculated with Pearson's r linear correlation coefficient and intraclass correlation coefficients (ICC) were calculated for inter- and intraobserver reliability. In addition, patients were examined in subgroups with respect to previous surgery and the current therapy. Lumbar lordosis averaged 45.6° (range 2.5°-74.9°; SD 14.2°), intraobserver correlation was between Pearson r = 0.93 and 0.98. The measurement of SS averaged 35.3° (range 13.8°-66.9°; SD 9.6°), intraobserver correlation was between Pearson r = 0.89 and 0.96. Intraobserver reliability ranged from 0.966 to 0.992 ICC in LL measurements and 0.944-0.983 ICC in SS measurements. There was an interobserver reliability ICC of 0.944 in LL and 0.990 in SS. Correlation between LL and SS averaged r = 0.79. No statistically significant differences were observed between the analyzed subgroups. Manual measurement of LL and SS in patients with LSS on lateral radiographs is easily performed with excellent intra- and interobserver reliability. Correlation between LL and SS is very high. Differences between patients with and without previous decompression were not statistically significant.

  4. Can Education Add Value to Values? A Study of Law Students

    ERIC Educational Resources Information Center

    Palermo, Josephine; Evans, Adrian

    2004-01-01

    In the global market place the value of education takes on many meanings. In transnational education forums it relates to the market's assessment (in dollar terms) of a qualification. But can we measure the value-addedness of tertiary education in existential terms? Can we measure the value that tertiary education provides to the enhancement of…

  5. Cultural Value, Measurement and Policy Making

    ERIC Educational Resources Information Center

    O'Brien, Dave

    2015-01-01

    No matter what the national context, the question of how to understand the impact of government programmes, particularly in terms of value for money, has emerged as a complex problem to be solved by social scientific management. This article engages with these trends in two ways. It focuses on the UK to understand how these tools and technologies…

  6. Identifying, Measuring and Monitoring Value during Project Development

    ERIC Educational Resources Information Center

    Kliniotou, Maria

    2004-01-01

    This paper describes the findings of the research done by Loughborough University in conjunction with ten construction industry collaborators in an attempt to identify what construction professionals mean by value. The aim of the research is to establish a common approach to identify value in projects and to monitor its development throughout the…

  7. Measuring the Value of New Drugs: Validity and Reliability of 4 Value Assessment Frameworks in the Oncology Setting.

    PubMed

    Bentley, Tanya G K; Cohen, Joshua T; Elkin, Elena B; Huynh, Julie; Mukherjea, Arnab; Neville, Thanh H; Mei, Matthew; Copher, Ronda; Knoth, Russell; Popescu, Ioana; Lee, Jackie; Zambrano, Jenelle M; Broder, Michael S

    2017-06-01

    Several organizations have developed frameworks to systematically assess the value of new drugs. To evaluate the convergent validity and interrater reliability of 4 value frameworks to understand the extent to which these tools can facilitate value-based treatment decisions in oncology. Eight panelists used the American Society of Clinical Oncology (ASCO), European Society for Medical Oncology (ESMO), Institute for Clinical and Economic Review (ICER), and National Comprehensive Cancer Network (NCCN) frameworks to conduct value assessments of 15 drugs for advanced lung and breast cancers and castration-refractory prostate cancer. Panelists received instructions and published clinical data required to complete the assessments, assigning each drug a numeric or letter score. Kendall's Coefficient of Concordance for Ranks (Kendall's W) was used to measure convergent validity by cancer type among the 4 frameworks. Intraclass correlation coefficients (ICCs) were used to measure interrater reliability for each framework across cancers. Panelists were surveyed on their experiences. Kendall's W across all 4 frameworks for breast, lung, and prostate cancer drugs was 0.560 (P= 0.010), 0.562 (P = 0.010), and 0.920 (P < 0.001), respectively. Pairwise, Kendall's W for breast cancer drugs was highest for ESMO-ICER and ICER-NCCN (W = 0.950, P = 0.019 for both pairs) and lowest for ASCO-NCCN (W = 0.300, P = 0.748). For lung cancer drugs, W was highest pairwise for ESMO-ICER (W = 0.974, P = 0.007) and lowest for ASCO-NCCN (W = 0.218, P = 0.839); for prostate cancer drugs, pairwise W was highest for ICER-NCCN (W = 1.000, P < 0.001) and lowest for ESMO-ICER and ESMO-NCCN (W = 0.900, P = 0.052 for both pairs). When ranking drugs on distinct framework subdomains, Kendall's W among breast cancer drugs was highest for certainty (ICER, NCCN: W = 0.908, P = 0.046) and lowest for clinical benefit (ASCO, ESMO, NCCN: W = 0.345, P = 0.436). Among lung cancer drugs, W was highest for toxicity

  8. The Study and Measurement of Values and Attitudes.

    ERIC Educational Resources Information Center

    Kerlinger, Fred N.

    The author defines values, attitudes, and beliefs according to their relation to referents. A referent is a construct standing for a set or category of social objects, ideas, or behaviors that is the focus of an attitude. Attitudes and values are belief systems. Beliefs are enduring cognitions about referents; beliefs reflect the value and…

  9. Spectrophotometric Measurement of Minimal Erythema Dose Sites after Narrowband Ultraviolet B Phototesting: Clinical Implication of Spetrophotometric Values in Phototherapy

    PubMed Central

    Jeon, Su-Young; Lee, Chae-Young; Song, Ki-Hoon

    2014-01-01

    Background The spectrophotometer is well known to be a useful tool for estimating the objective minimal erythema dose (MED) during planning of phototherapy protocol. However, only a few spectrophotometric values are used to evaluate the erythema and pigmentation of the MED site during phototesting. Objective To determinea new meaning of the relationships among spectrophotometric values during phototesting. Methods Twenty-five patients with psoriasis and 23 patients with vitiligo were selected before undergoing narrowband ultraviolet B phototherapy. We interpreted the gross findings of erythema and measured the L*a*b* values using a spectrophotometer at each phototest spot. We compared MEDs, basic spectrophotometric values (L*a*b*), and b*/L* values separately according to skin type, and determined the correlation of each spectrophotometric value and the correlation between a* and b*/L* values. Results Among L*a*b* values, only b* values showed a statistically significant difference between the type III and IV groups (p=0.003). There was a positive correlation only between MEDs and b* values (p<0.05). The average b*/L*value in the type IV group was significantly higher than the type III group (p<0.05). Conclusion The higher b* values in type IV skin indicates that skin tanning develops more prominently than type III. The correlation between MEDs and b* values may signify that the skin pigmentation status is deepened with the higher MEDs. The difference in b*/L*values between type III and IV skin reflects that the b*/L*value is thought to be an index of tanning. The a* value, known as an index of erythema, does not influence the degree of tanning. PMID:24648682

  10. SeHCAT retention values as measured with a collimated and an uncollimated gamma camera: a method comparison study.

    PubMed

    Wright, James W; Lovell, Lesley A; Gemmell, Howard G; McKiddie, Fergus; Staff, Roger T

    2013-07-01

    TauroH-23-(Se) selena-25-homocholic acid retention values are used in the diagnosis of bile acid malabsorption. The standard method for measuring values is with an uncollimated gamma camera, which can create some logistic difficulties, with other background sources of activity, which are irrelevant when a collimator is used, becoming significant. In this study we compare the retention values obtained with a collimated and an uncollimated gamma camera in phantoms and in 23 patients. Bland-Altman plots were created using the data, which showed a mean bias in retention of 0.10% in the phantom study and 0.55% in the patient study between methods. A Wilcoxon signed-rank test with the null hypothesis of zero median difference between uncollimated and collimated methods was not statistically significant to P values less than 0.05 in the patient and phantom studies. In the patient study, on using a fixed boundary of retention (10%) between positive and negative status, the status of one patient was changed from negative (12%) to positive (9%). We conclude that measurement of retention with a collimated gamma camera is similar but not identical to that of uncollimated values. The clinical significance of this shift is unclear, as the threshold of significance and the method of integrating this measure with other clinical factors into management remain unclear.

  11. Measuring the Value of Succession Planning and Management: A Qualitative Study of Multinational Companies

    ERIC Educational Resources Information Center

    Kim, Yeonsoo

    2010-01-01

    This article proposes a model for planning and operating an effective succession planning and management (SP&M) program and measuring its value. The nature of the research is exploratory, following a qualitative approach using in-depth interviews. Representatives of multinational companies interviewed for this study revealed that succession…

  12. Presenting Cost and Efficiency Measures That Support Consumers to Make High-Value Health Care Choices.

    PubMed

    Greene, Jessica; Sacks, Rebecca M

    2018-02-25

    To identify approaches to presenting cost and resource use measures that support consumers in selecting high-value hospitals. Survey data were collected from U.S. employees of Analog Devices (n = 420). In two online experiments, participants viewed comparative data on four hospitals. In one experiment, participants were randomized to view one of five versions of the same comparative cost data, and in the other experiment they viewed different versions of the same readmissions data. Bivariate and multivariate analyses examined whether presentation approach was related to selecting the high-value hospital. Consumers were approximately 16 percentage points more likely to select a high-value hospital when cost data were presented using actual dollar amounts or using the word "affordable" to describe low-cost hospitals, compared to when the Hospital Compare spending ratio was used. Consumers were 33 points more likely to select the highest performing hospital when readmission performance was shown using word icons rather than percentages. Presenting cost and resource use measures effectively to consumers is challenging. This study suggests using actual dollar amounts for cost, but presenting performance on readmissions using evaluative symbols. © Health Research and Educational Trust.

  13. Comparison of Low Energy CVV Auger transitions in Cu and Au (100) using Measured and estimated values

    NASA Astrophysics Data System (ADS)

    Shastry, K.; Mukherjee, S. F.; Satyal, S.; Joglekar, P. V.; Weiss, A. H.

    2011-10-01

    Low energy Auger lineshapes are difficult to measure because they sit on a large background due to secondary electrons arising from loss processes unrelated to the Auger mechanism. In this poster we discuss the implications of our PAES measurements of the ratio of the integrated Auger Peak and integrated low energy tail (LET) intensities for comparisons between theoretical and measured values of the Auger intensities. The experiments were carried out at university of Texas at Arlington on Cu (100) and Au (100) crystals. Our conclusions regarding the importance of the LET in determining the ratio of electrons in the Auger peak to the number of initial core holes are discussed in light of the electron stimulated Auger results obtained by Seah et.al using monte carlo simulations on various elements.

  14. Deodorants, value, and performance.

    PubMed

    Newcomer, L N

    1997-11-01

    For the health-care market, like the deodorant market, the message is clear: Add value or your product will not be competitive. For physicians of all specialties, the best way to add value is to measure and improve performance. Performance measurement is critical to improvement in health care. Without measurement, there can be no improvement in quality. Without improvement in quality, there is no added value. Oncologists can take at least two actions to add value for their health plans: (1) measure practice performance and demonstrate a quality improvement; and (2) become the personal-care physician for cancer patients.

  15. Value-based care in hepatology.

    PubMed

    Strazzabosco, Mario; Allen, John I; Teisberg, Elizabeth O

    2017-05-01

    The migration from legacy fee-for-service reimbursement to payments linked to high-value health care is accelerating in the United States because of new legislation and redesign of payments from the Centers for Medicare and Medicaid Services. Because patients with chronic diseases account for substantial use of health care resources, payers and health systems are focusing on maximizing the value of care for these patients. Because chronic liver diseases impose a major health burden worldwide affecting the health and lives of many individuals and families as well as substantial costs for individuals and payers, hepatologists must understand how they can improve their practices. Hepatologists practice a high-intensity cognitive subspecialty, using complex and costly procedures and medications. High-value patient care requires multidisciplinary coordination, labor-intensive support for critically ill patients, and effective chronic disease management. Under current fee-for-service reimbursement, patient values, medical success, and financial success can all be misaligned. Many current attempts to link health outcomes to reimbursement are based on compliance with process measures, with less emphasis on outcomes that matter most to patients, thus slowing transformation to higher-value team-based care. Outcome measures that reflect the entire cycle of care are needed to assist both clinicians and administrators in improving the quality and value of care. A comprehensive set of outcome measures for liver diseases is not currently available. Numerous researchers now are attempting to fill this gap by devising and testing outcome indicators and patient-reported outcomes for the major liver conditions. These indicators will provide tools to implement a value-based approach for patients with chronic liver diseases to compare results and value of care between referral centers, to perform health technology assessment, and to guide decision-making processes for health

  16. ARFI quantitative elastography of the submandibular glands. Normal measurements and the diagnosis value of the method in radiation submaxillitis.

    PubMed

    Badea, Alexandru Florin; Tamas Szora, Attila; Ciuleanu, Elisabeta; Chioreanu, Ioana; Băciuţ, Grigore; Lupşor Platon, Monica; Badea, Radu

    2013-09-01

    Evaluation of Acoustic Radiation Force Impulse Imaging (ARFI) elastography performance in predicting the elasticity of the submandibular glands in normal situations and after radiation therapy. A number of 54 normal submandibular glands from 27 voluntary subjects and 33 pathological submandibular glands (radiation submaxillities) from 18 patients who had undergone radiation therapy for various cervical and facial oncological conditions were included in study. All the patients had undergone a B mode ultrasonography (Tissue Harmonic Imaging, 8-14 MHz) while the submandibular volume was determined and subsequently an ARFI examination while the shear wave velocity (SWV) was measured (in the central, peripheral and subcapsular areas, with the results expressed in m/s). In the volunteers' group the mean value of the SWV of the left submandibular gland was 1.68 ± 0.46 m/s, determined in the centre of the gland, 1.88 ± 0.4 m/s in the periphery (corresponding to the subcapsular parenchyma) and the SWV of the right submandibular gland was 1.74 ± 0.35 m/s (centrally) and 1.84 ± 0.43 m/s in the periphery. The mean value of all measurements was 1.82 ± 0.41 m/s. The mean volume of the glands was 7.97 ± 2.63 cm3. In the group of patients who had underwent radiation therapy (at least 35Gy), the mean value of the SWV was 2.24 ± 0.49 m/s centrally and 2.1 ± 0.58 m/s in the periphery on the left and 1.99 ± 0.5 m/s centrally and 2.21 ± 0.52 m/s in the periphery on the right. The mean value of all the measurements was 2.13 ± 0.52 m/s and the mean volume of the gland was 5.95 ± 4.16 cm3. Elastography using ARFI technique is a valid examination in the evaluation of the normal and pathological submandibular gland stiffness. The values of the shear wave velocities that correspond to a normal stiffness, determined through the ARFI technique, are similar in the two glands. After cervical and facial radiation therapy the values of the SWV are increased, indicating a change in the

  17. Measuring the Value of Public Health Systems: The Disconnect Between Health Economists and Public Health Practitioners

    PubMed Central

    Jacobson, Peter D.; Palmer, Jennifer A.

    2008-01-01

    We investigated ways of defining and measuring the value of services provided by governmental public health systems. Our data sources included literature syntheses and qualitative interviews of public health professionals. Our examination of the health economic literature revealed growing attempts to measure value of public health services explicitly, but few studies have addressed systems or infrastructure. Interview responses demonstrated no consensus on metrics and no connection to the academic literature. Key challenges for practitioners include developing rigorous, data-driven methods and skilled staff; being politically willing to base allocation decisions on economic evaluation; and developing metrics to capture “intangibles” (e.g., social justice and reassurance value). Academic researchers evaluating the economics of public health investments should increase focus on the working needs of public health professionals. PMID:18923123

  18. Career Assessment: Interest and Values Measures for Tech Prep and School-to-Work Programs.

    ERIC Educational Resources Information Center

    Kapes, Jerome T.; Martinez, Linda

    This paper describes and compares interests and values measures useful for career assessment and counseling in tech prep and school-to-work programs. The primary source of information for this information is the third edition of "A Counselor's Guide to Career Assessment Instruments" (Kapes, Mastie, and Whitfield 1994). Stated objectives…

  19. Translating HbA1c measurements into estimated average glucose values in pregnant women with diabetes.

    PubMed

    Law, Graham R; Gilthorpe, Mark S; Secher, Anna L; Temple, Rosemary; Bilous, Rudolf; Mathiesen, Elisabeth R; Murphy, Helen R; Scott, Eleanor M

    2017-04-01

    This study aimed to examine the relationship between average glucose levels, assessed by continuous glucose monitoring (CGM), and HbA 1c levels in pregnant women with diabetes to determine whether calculations of standard estimated average glucose (eAG) levels from HbA 1c measurements are applicable to pregnant women with diabetes. CGM data from 117 pregnant women (89 women with type 1 diabetes; 28 women with type 2 diabetes) were analysed. Average glucose levels were calculated from 5-7 day CGM profiles (mean 1275 glucose values per profile) and paired with a corresponding (±1 week) HbA 1c measure. In total, 688 average glucose-HbA 1c pairs were obtained across pregnancy (mean six pairs per participant). Average glucose level was used as the dependent variable in a regression model. Covariates were gestational week, study centre and HbA 1c . There was a strong association between HbA 1c and average glucose values in pregnancy (coefficient 0.67 [95% CI 0.57, 0.78]), i.e. a 1% (11 mmol/mol) difference in HbA 1c corresponded to a 0.67 mmol/l difference in average glucose. The random effects model that included gestational week as a curvilinear (quadratic) covariate fitted best, allowing calculation of a pregnancy-specific eAG (PeAG). This showed that an HbA 1c of 8.0% (64 mmol/mol) gave a PeAG of 7.4-7.7 mmol/l (depending on gestational week), compared with a standard eAG of 10.2 mmol/l. The PeAG associated with maintaining an HbA 1c level of 6.0% (42 mmol/mol) during pregnancy was between 6.4 and 6.7 mmol/l, depending on gestational week. The HbA 1c -average glucose relationship is altered by pregnancy. Routinely generated standard eAG values do not account for this difference between pregnant and non-pregnant individuals and, thus, should not be used during pregnancy. Instead, the PeAG values deduced in the current study are recommended for antenatal clinical care.

  20. Applying the Expectancy-Value Model to understand health values.

    PubMed

    Zhang, Xu-Hao; Xie, Feng; Wee, Hwee-Lin; Thumboo, Julian; Li, Shu-Chuen

    2008-03-01

    Expectancy-Value Model (EVM) is the most structured model in psychology to predict attitudes by measuring attitudinal attributes (AAs) and relevant external variables. Because health value could be categorized as attitude, we aimed to apply EVM to explore its usefulness in explaining variances in health values and investigate underlying factors. Focus group discussion was carried out to identify the most common and significant AAs toward 5 different health states (coded as 11111, 11121, 21221, 32323, and 33333 in EuroQol Five-Dimension (EQ-5D) descriptive system). AAs were measured in a sum of multiplications of subjective probability (expectancy) and perceived value of attributes with 7-point Likert scales. Health values were measured using visual analog scales (VAS, range 0-1). External variables (age, sex, ethnicity, education, housing, marital status, and concurrent chronic diseases) were also incorporated into survey questionnaire distributed by convenience sampling among eligible respondents. Univariate analyses were used to identify external variables causing significant differences in VAS. Multiple linear regression model (MLR) and hierarchical regression model were used to investigate the explanatory power of AAs and possible significant external variable(s) separately or in combination, for each individual health state and a mixed scenario of five states, respectively. Four AAs were identified, namely, "worsening your quality of life in terms of health" (WQoL), "adding a burden to your family" (BTF), "making you less independent" (MLI) and "unable to work or study" (UWS). Data were analyzed based on 232 respondents (mean [SD] age: 27.7 [15.07] years, 49.1% female). Health values varied significantly across 5 health states, ranging from 0.12 (33333) to 0.97 (11111). With no significant external variables identified, EVM explained up to 62% of the variances in health values across 5 health states. The explanatory power of 4 AAs were found to be between 13

  1. A novel scoring system to measure radiographic abnormalities and related spirometric values in cured pulmonary tuberculosis.

    PubMed

    Báez-Saldaña, Renata; López-Arteaga, Yesenia; Bizarrón-Muro, Alma; Ferreira-Guerrero, Elizabeth; Ferreyra-Reyes, Leticia; Delgado-Sánchez, Guadalupe; Cruz-Hervert, Luis Pablo; Mongua-Rodríguez, Norma; García-García, Lourdes

    2013-01-01

    Despite chemotherapy, patients with cured pulmonary tuberculosis may result in lung functional impairment. To evaluate a novel scoring system based on the degree of radiographic abnormalities and related spirometric values in patients with cured pulmonary tuberculosis. One hundred and twenty seven patients with cured pulmonary tuberculosis were prospectively enrolled in a referral hospital specializing in respiratory diseases. Spirometry was performed and the extent of radiographic abnormalities was evaluated twice by each of two readers to generate a novel quantitative score. Scoring reproducibility was analyzed by the intra-class correlation coefficient (ICC) and the Bland-Altman method. Multiple linear regression models were performed to assess the association of the extent of radiographic abnormalities with spirometric values. The intra-observer agreement for scoring of radiographic abnormalities (SRA) showed an ICC of 0.81 (CI:95%, 0.67-0.95) and 0.78 (CI:95%, 0.65-0.92), for reader 1 and 2, respectively. Inter-observer reproducibility for the first measurement was 0.83 (CI:95%, 0.71-0.95), and for the second measurement was 0.74 (CI:95%, 0.58-0.90). The Bland-Altman analysis of the intra-observer agreement showed a mean bias of 0.87% and -0.55% and an inter-observer agreement of -0.35% and -1.78%, indicating a minor average systematic variability. After adjustment for age, gender, height, smoking status, pack-years of smoking, and degree of dyspnea, the scoring degree of radiographic abnormalities was significantly and negatively associated with absolute and percent predicted values of FVC: -0.07 (CI:95%, -0.01 to -0.04); -2.48 (CI:95%, -3.45 to -1.50); and FEV1 -0.07 (CI:95%, -0.10 to -0.05); -2.92 (CI:95%, -3.87 to -1.97) respectively, in the patients studied. The extent of radiographic abnormalities, as evaluated through our novel scoring system, was inversely associated with spirometric values, and exhibited good reliability and reproducibility. As intra

  2. A Novel Scoring System to Measure Radiographic Abnormalities and Related Spirometric Values in Cured Pulmonary Tuberculosis

    PubMed Central

    Báez-Saldaña, Renata; López-Arteaga, Yesenia; Bizarrón-Muro, Alma; Ferreira-Guerrero, Elizabeth; Ferreyra-Reyes, Leticia; Delgado-Sánchez, Guadalupe; Cruz-Hervert, Luis Pablo; Mongua-Rodríguez, Norma; García-García, Lourdes

    2013-01-01

    Background Despite chemotherapy, patients with cured pulmonary tuberculosis may result in lung functional impairment. Objective To evaluate a novel scoring system based on the degree of radiographic abnormalities and related spirometric values in patients with cured pulmonary tuberculosis. Methods One hundred and twenty seven patients with cured pulmonary tuberculosis were prospectively enrolled in a referral hospital specializing in respiratory diseases. Spirometry was performed and the extent of radiographic abnormalities was evaluated twice by each of two readers to generate a novel quantitative score. Scoring reproducibility was analyzed by the intra-class correlation coefficient (ICC) and the Bland-Altman method. Multiple linear regression models were performed to assess the association of the extent of radiographic abnormalities with spirometric values. Results The intra-observer agreement for scoring of radiographic abnormalities (SRA) showed an ICC of 0.81 (CI:95%, 0.67–0.95) and 0.78 (CI:95%, 0.65–0.92), for reader 1 and 2, respectively. Inter-observer reproducibility for the first measurement was 0.83 (CI:95%, 0.71–0.95), and for the second measurement was 0.74 (CI:95%, 0.58–0.90). The Bland-Altman analysis of the intra-observer agreement showed a mean bias of 0.87% and -0.55% and an inter-observer agreement of -0.35% and -1.78%, indicating a minor average systematic variability. After adjustment for age, gender, height, smoking status, pack-years of smoking, and degree of dyspnea, the scoring degree of radiographic abnormalities was significantly and negatively associated with absolute and percent predicted values of FVC: -0.07 (CI:95%, -0.01 to -0.04); -2.48 (CI:95%, -3.45 to -1.50); and FEV1 -0.07 (CI:95%, -0.10 to -0.05); -2.92 (CI:95%, -3.87 to -1.97) respectively, in the patients studied. Conclusion The extent of radiographic abnormalities, as evaluated through our novel scoring system, was inversely associated with spirometric values, and

  3. Weak value controversy

    NASA Astrophysics Data System (ADS)

    Vaidman, L.

    2017-10-01

    Recent controversy regarding the meaning and usefulness of weak values is reviewed. It is argued that in spite of recent statistical arguments by Ferrie and Combes, experiments with anomalous weak values provide useful amplification techniques for precision measurements of small effects in many realistic situations. The statistical nature of weak values is questioned. Although measuring weak values requires an ensemble, it is argued that the weak value, similarly to an eigenvalue, is a property of a single pre- and post-selected quantum system. This article is part of the themed issue `Second quantum revolution: foundational questions'.

  4. Value and Performance in the IT Society.

    ERIC Educational Resources Information Center

    Bryson, Jo

    This paper discusses valuing information and its supporting technologies in the global environment. Different value propositions are explored from a financial, social, cultural, political, economic, corporate, and personal values perspective. Various means of measuring the relevancy of these value propositions to the individual, organization or…

  5. Human Rights Values or Cultural Values? Pursuing Values to Maintain Positive Discipline in Multicultural Schools

    ERIC Educational Resources Information Center

    du Preez, Petro; Roux, Cornelia

    2010-01-01

    Discussions on discipline in education often accentuate corporal punishment or measures to infuse moral fibre. In addition, many authors argue that inculcating a particular value system can promote discipline in schools. This could however be profoundly problematic in the light of the Constitution. We argue that positive discipline in…

  6. Building the Infrastructure for Value at UCLA: Engaging Clinicians and Developing Patient-Centric Measurement.

    PubMed

    Clarke, Robin; Hackbarth, Andrew S; Saigal, Christopher; Skootsky, Samuel A

    2015-10-01

    Evolving payer and patient expectations have challenged academic health centers (AHCs) to improve the value of clinical care. Traditional quality approaches may be unable to meet this challenge. One AHC, UCLA Health, has implemented a systematic approach to delivery system redesign that emphasizes clinician engagement, a patient-centric scope, and condition-specific, clinician-guided measurement. A physician champion serves as quality officer (QO) for each clinical department/division. Each QO, with support from a central measurement team, has developed customized analytics that use clinical data to define targeted populations and measure care across the full treatment episode. From October 2012 through June 2015, the approach developed rapidly. Forty-three QOs are actively redesigning care delivery protocols within their specialties, and 95% of the departments/divisions have received a customized measure report for at least one patient population. As an example of how these analytics promote systematic redesign, the authors discuss how Department of Urology physicians have used these new measures, first, to better understand the relationship between clinical practice and outcomes for patients with benign prostatic hyperplasia and, then, to work toward reducing unwarranted variation. Physicians have received these efforts positively. Early outcome data are encouraging. This infrastructure of engaged physicians and targeted measurement is being used to implement systematic care redesign that reliably achieves outcomes that are meaningful to patients and clinicians-incorporating both clinical and cost considerations. QOs are using an approach, for multiple newly launched projects, to identify, test, and implement value-oriented interventions tailored to specific patient populations.

  7. Establishment of a Method to Measure Length of the Ulnar Nerve and Standardize F-wave Values in Clinically Normal Beagles

    PubMed Central

    HIRASAWA, Shun; SHIMIZU, Miki; MARUI, Yuumi; KISHIMOTO, Miori; OKUNO, Seiichi

    2014-01-01

    We designed a new method of measuring the length of the ulnar nerve and determining standard values for F-wave parameters of the ulnar nerve in clinically normal beagles. Nerve length must be precisely measured to determine F-wave latency and conduction velocity. The length of the forelimb has served as the length of the ulnar nerve for F-wave assessments, but report indicates that F-wave latency is proportional to the length of the pathway traveled by nerve impulses. Therefore, we measured the surface distance from a stimulus point to the spinous process of the first thoracic vertebra (nerve length 1) and the anterior horn of the scapula (nerve length 2) as landmarks through the olecranon and the shoulder blade acromion. The correlation coefficients between the shortest F-wave latency and the length of nerves 1, 2 or the forelimb were 0.61, 0.7 and 0.58. Nerve length 2 generated the highest value. Furthermore, the anterior horn of the scapula was easily palpated in any dog regardless of well-fed body. We concluded that nerve length 2 was optimal for measuring the length of the ulnar nerve. PMID:25649942

  8. Measuring temporal stability of positron emission tomography standardized uptake value bias using long-lived sources in a multicenter network.

    PubMed

    Byrd, Darrin; Christopfel, Rebecca; Arabasz, Grae; Catana, Ciprian; Karp, Joel; Lodge, Martin A; Laymon, Charles; Moros, Eduardo G; Budzevich, Mikalai; Nehmeh, Sadek; Scheuermann, Joshua; Sunderland, John; Zhang, Jun; Kinahan, Paul

    2018-01-01

    Positron emission tomography (PET) is a quantitative imaging modality, but the computation of standardized uptake values (SUVs) requires several instruments to be correctly calibrated. Variability in the calibration process may lead to unreliable quantitation. Sealed source kits containing traceable amounts of [Formula: see text] were used to measure signal stability for 19 PET scanners at nine hospitals in the National Cancer Institute's Quantitative Imaging Network. Repeated measurements of the sources were performed on PET scanners and in dose calibrators. The measured scanner and dose calibrator signal biases were used to compute the bias in SUVs at multiple time points for each site over a 14-month period. Estimation of absolute SUV accuracy was confounded by bias from the solid phantoms' physical properties. On average, the intrascanner coefficient of variation for SUV measurements was 3.5%. Over the entire length of the study, single-scanner SUV values varied over a range of 11%. Dose calibrator bias was not correlated with scanner bias. Calibration factors from the image metadata were nearly as variable as scanner signal, and were correlated with signal for many scanners. SUVs often showed low intrascanner variability between successive measurements but were also prone to shifts in apparent bias, possibly in part due to scanner recalibrations that are part of regular scanner quality control. Biases of key factors in the computation of SUVs were not correlated and their temporal variations did not cancel out of the computation. Long-lived sources and image metadata may provide a check on the recalibration process.

  9. Values in Prime Time Alcoholic Beverage Commercials.

    ERIC Educational Resources Information Center

    Frazer, Charles F.

    Content analysis was used to study the values evident in televised beer and wine commercials. Seventy-seven prime time commercials, 7.6% of a week's total, were analyzed along value dimensions adapted from Gallup's measure of popular social values. The intensity of each value was coded on a five-point scale. None of the commercials in the beer and…

  10. Non-Markovian stochastic Schrödinger equations: Generalization to real-valued noise using quantum-measurement theory

    NASA Astrophysics Data System (ADS)

    Gambetta, Jay; Wiseman, H. M.

    2002-07-01

    Do stochastic Schrödinger equations, also known as unravelings, have a physical interpretation? In the Markovian limit, where the system on average obeys a master equation, the answer is yes. Markovian stochastic Schrödinger equations generate quantum trajectories for the system state conditioned on continuously monitoring the bath. For a given master equation, there are many different unravelings, corresponding to different sorts of measurement on the bath. In this paper we address the non-Markovian case, and in particular the sort of stochastic Schrödinger equation introduced by Strunz, Diósi, and Gisin [Phys. Rev. Lett. 82, 1801 (1999)]. Using a quantum-measurement theory approach, we rederive their unraveling that involves complex-valued Gaussian noise. We also derive an unraveling involving real-valued Gaussian noise. We show that in the Markovian limit, these two unravelings correspond to heterodyne and homodyne detection, respectively. Although we use quantum-measurement theory to define these unravelings, we conclude that the stochastic evolution of the system state is not a true quantum trajectory, as the identity of the state through time is a fiction.

  11. Performance Measures, Benchmarking and Value.

    ERIC Educational Resources Information Center

    McGregor, Felicity

    This paper discusses performance measurement in university libraries, based on examples from the University of Wollongong (UoW) in Australia. The introduction highlights the integration of information literacy into the curriculum and the outcomes of a 1998 UoW student satisfaction survey. The first section considers performance indicators in…

  12. Standard values of maximum tongue pressure taken using newly developed disposable tongue pressure measurement device.

    PubMed

    Utanohara, Yuri; Hayashi, Ryo; Yoshikawa, Mineka; Yoshida, Mitsuyoshi; Tsuga, Kazuhiro; Akagawa, Yasumasa

    2008-09-01

    It is clinically important to evaluate tongue function in terms of rehabilitation of swallowing and eating ability. We have developed a disposable tongue pressure measurement device designed for clinical use. In this study we used this device to determine standard values of maximum tongue pressure in adult Japanese. Eight hundred fifty-three subjects (408 male, 445 female; 20-79 years) were selected for this study. All participants had no history of dysphagia and maintained occlusal contact in the premolar and molar regions with their own teeth. A balloon-type disposable oral probe was used to measure tongue pressure by asking subjects to compress it onto the palate for 7 s with maximum voluntary effort. Values were recorded three times for each subject, and the mean values were defined as maximum tongue pressure. Although maximum tongue pressure was higher for males than for females in the 20-49-year age groups, there was no significant difference between males and females in the 50-79-year age groups. The maximum tongue pressure of the seventies age group was significantly lower than that of the twenties to fifties age groups. It may be concluded that maximum tongue pressures were reduced with primary aging. Males may become weaker with age at a faster rate than females; however, further decreases in strength were in parallel for male and female subjects.

  13. Measuring and predicting Delta(vap)H298 values of ionic liquids.

    PubMed

    Deyko, Alexey; Lovelock, Kevin R J; Corfield, Jo-Anne; Taylor, Alasdair W; Gooden, Peter N; Villar-Garcia, Ignacio J; Licence, Peter; Jones, Robert G; Krasovskiy, Vladimir G; Chernikova, Elena A; Kustov, Leonid M

    2009-10-14

    We report the enthalpies of vaporisation (measured using temperature programmed desorption by mass spectrometry) of twelve ionic liquids (ILs), covering four imidazolium, [C(m)C(n)Im]+, five pyrrolidinium, [C(n)C(m)Pyrr]+, two pyridinium, [C(n)Py]+, and a dication, [C3(C1Im)2]2+ based IL. These cations were paired with a range of anions: [BF4]-, [FeCl4]-, [N(CN)2]-, [PF3(C2F5)3]- ([FAP]-), [(CF3SO2)2N]- ([Tf2N]-) and [SCN]-. Using these results, plus those for a further eight imidazolium based ILs published earlier (which include the anions [CF3SO3]- ([TfO]-), [PF6]- and [EtSO4]-), we show that the enthalpies of vaporisation can be decomposed into three components. The first component is the Coulombic interaction between the ions, DeltaU(Cou,R), which is a function of the IL molar volume, V(m), and a parameter R(r) which quantifies the relative change in anion-cation distance on evaporation from the liquid phase to the ion pair in the gas phase. The second and third components are the van der Waals contributions from the anion, DeltaH(vdw,A), and the cation, DeltaH(vdw,C). We derive a universal value for R(r), and individual values of DeltaH(vdw,A) and DeltaH(vdw,C) for each of the anions and cations considered in this study. Given the molar volume, it is possible to estimate the enthalpies of vaporisation of ILs composed of any combination of the ions considered here; values for fourteen ILs which have not yet been studied experimentally are given.

  14. How Do Value-Added Indicators Compare to Other Measures of Teacher Effectiveness? What We Know Series: Value-Added Methods and Applications. Knowledge Brief 5

    ERIC Educational Resources Information Center

    Harris, Douglas N.

    2012-01-01

    In the recent drive to revamp teacher evaluation and accountability, measures of a teacher's value added have played the starring role. But the star of the show is not always the best actor, nor can the star succeed without a strong supporting cast. In assessing teacher performance, observations of classroom practice, portfolios of teachers' work,…

  15. Individual differences in valuing mates' physical attractiveness.

    PubMed

    Mathes, Eugene W; Bielser, Abby; Cassell, Ticcarra; Summers, Sarah; Witowski, Aggie

    2006-10-01

    To investigate correlates of valuing physical attractiveness in a mate, it was hypothesized that valuing physical attractiveness in a mate would correlate with sex and valuing promiscuous sex, status, personal physical attractiveness, beauty, and order. Men and women college students completed measures of the extent to which they valued physical attractiveness in a mate and other variables. Valuing physical attractiveness in a mate was correlated with sex (men valued physical attractiveness in a mate more than did women) and valuing promiscuous sex and status, and, for women, valuing personal physical attractiveness. The results were explained in terms of evolutionary theory.

  16. The equivalence of two phylogenetic biodiversity measures: the Shapley value and Fair Proportion index.

    PubMed

    Hartmann, Klaas

    2013-11-01

    Most biodiversity conservation programs are forced to prioritise species in order to allocate their funding. This paper contains a mathematical proof that provides biological support for one common approach based on phylogenetic indices. Phylogenetic trees describe the evolutionary relationships between a group of taxa. Two indices for computing the distinctiveness of each taxon in a phylogenetic tree are considered here-the Shapley value and the Fair Proportion index. These indices provide a measure of the importance of each taxon for overall biodiversity and have been used to prioritise taxa for conservation. The Shapley value is the biodiversity contribution a taxon is expected to make if all taxa are equally likely to become extinct. This interpretation makes it appealing to use the Shapley value in biodiversity conservation applications. The Fair Proportion index lacks a convenient interpretation, however it is significantly easier to calculate and understand. It has been empirically observed that there is a high correlation between the two indices. This paper shows the mathematical basis for this correlation and proves that as the number of taxa increases, the indices become equivalent. Consequently in biodiversity prioritisation the simpler Fair Proportion index can be used whilst retaining the appealing interpretation of the Shapley value.

  17. Counting missing values in a metabolite-intensity data set for measuring the analytical performance of a metabolomics platform.

    PubMed

    Huan, Tao; Li, Liang

    2015-01-20

    Metabolomics requires quantitative comparison of individual metabolites present in an entire sample set. Unfortunately, missing intensity values in one or more samples are very common. Because missing values can have a profound influence on metabolomic results, the extent of missing values found in a metabolomic data set should be treated as an important parameter for measuring the analytical performance of a technique. In this work, we report a study on the scope of missing values and a robust method of filling the missing values in a chemical isotope labeling (CIL) LC-MS metabolomics platform. Unlike conventional LC-MS, CIL LC-MS quantifies the concentration differences of individual metabolites in two comparative samples based on the mass spectral peak intensity ratio of a peak pair from a mixture of differentially labeled samples. We show that this peak-pair feature can be explored as a unique means of extracting metabolite intensity information from raw mass spectra. In our approach, a peak-pair peaking algorithm, IsoMS, is initially used to process the LC-MS data set to generate a CSV file or table that contains metabolite ID and peak ratio information (i.e., metabolite-intensity table). A zero-fill program, freely available from MyCompoundID.org , is developed to automatically find a missing value in the CSV file and go back to the raw LC-MS data to find the peak pair and, then, calculate the intensity ratio and enter the ratio value into the table. Most of the missing values are found to be low abundance peak pairs. We demonstrate the performance of this method in analyzing an experimental and technical replicate data set of human urine metabolome. Furthermore, we propose a standardized approach of counting missing values in a replicate data set as a way of gauging the extent of missing values in a metabolomics platform. Finally, we illustrate that applying the zero-fill program, in conjunction with dansylation CIL LC-MS, can lead to a marked improvement in

  18. The Bungee Jumper: A Comparison of Predicted and Measured Values

    NASA Astrophysics Data System (ADS)

    Biezeveld, Hubert

    2003-04-01

    The greater-than-g acceleration of a bungee jumper discussed in a previous article in this journal by Kagan and Kott led to many lively discussions among Dutch physics teachers. These inspired me to look for an inexpensive experimental setup, suitable for use in a high school physics class, that can be used to confirm that indeed the acceleration is greater than g. In this paper I describe an exercise to compare the predicted and the measured graphs for the displacement y(t) of the jumper and the force Fb(t) exerted by the bungee on the bridge to which it is fastened. In my apparatus, the "bungee" consists of a light chain and the "jumper" is a small piece of brass. Data collection and the calculation of predicted values were carried out using Coach.2 The analysis reliably leads to the conclusion that the acceleration of the falling jumper does indeed exceed g.

  19. Development and testing of an instrument to measure holistic nursing values in nurse practitioner care.

    PubMed

    Kinchen, Elizabeth

    2015-01-01

    As primary care delivery evolves in the United States with nurse practitioners (NPs) as key providers, exploring the patient's perception of the nature and quality of NPs' care is of critical importance to healthcare consumers, providers, educators, policy makers, and underwriters. The aim of this study was to describe the development and testing of the Nurse Practitioner Holistic Caring Instrument, a new, investigator-developed measure of the preservation of holistic nursing values in NP care. Results suggest that NPs provide patient-centered, comprehensive, and clinically competent care, rendering them ideally suited to leading primary health care delivery. However, further testing in more diverse populations and settings is needed to strengthen preliminary findings.

  20. Quality-adjusted cost of care: a meaningful way to measure growth in innovation cost versus the value of health gains.

    PubMed

    Lakdawalla, Darius; Shafrin, Jason; Lucarelli, Claudio; Nicholson, Sean; Khan, Zeba M; Philipson, Tomas J

    2015-04-01

    Technology drives both health care spending and health improvement. Yet policy makers rarely see measures of cost growth that account for both effects. To fill this gap, we present the quality-adjusted cost of care, which illustrates cost growth net of growth in the value of health improvements, measured as survival gains multiplied by the value of survival. We applied the quality-adjusted cost of care to two cases. For colorectal cancer, drug cost per patient increased by $34,493 between 1998 and 2005 as a result of new drug launches, but value from offsetting health improvements netted a modest $1,377 increase in quality-adjusted cost of care. For multiple myeloma, new therapies increased treatment cost by $72,937 between 2004 and 2009, but offsetting health benefits lowered overall quality-adjusted cost of care by $67,863. However, patients with multiple myeloma on established first-line therapies saw costs rise without corresponding benefits. All three examples document rapid cost growth, but they provide starkly different answers to the question of whether society got what it paid for. Project HOPE—The People-to-People Health Foundation, Inc.

  1. Value measurement in health care: a new perspective.

    PubMed

    Michelman, J E; Rausch, P E; Barton, T L

    1999-08-01

    Vital to the success of any healthcare organization is the ability to obtain useful information and feedback about its performance. In particular, healthcare organizations need to begin to understand how non-value-adding work activities detract from their bottom lines. Additionally, financial managers and information systems need to provide data and reports throughout the continuum of care. Overall, healthcare organizations must align the management information and control systems with the planning and decision-making processes. The horizontal information system is a tool to manage three common problems facing today's healthcare managers: (1) the use of existing information to focus on control rather than improve business, (2) failure to focus on satisfying the customer, and (3) failure to combine their efforts with those of the employees by developing trust and a common focus.

  2. Low-Value Medical Services in the Safety-Net Population

    PubMed Central

    Linder, Jeffrey A.; Clark, Cheryl R.; Sommers, Benjamin D.

    2017-01-01

    Importance National patterns of low-value and high-value care delivered to patients without insurance or with Medicaid could inform public policy but have not been previously examined. Objective To measure rates of low-value care and high-value care received by patients without insurance or with Medicaid, compared with privately insured patients, and provided by safety-net physicians vs non–safety-net physicians. Design, Setting, and Participants This multiyear cross-sectional observational study included all patients ages 18 to 64 years from the National Ambulatory Medical Care Survey (2005-2013) and the National Hospital Ambulatory Medical Care Survey (2005-2011) eligible for any of the 21 previously defined low-value or high-value care measures. All measures were analyzed with multivariable logistic regression and adjusted for patient and physician characteristics. Exposures Comparison of patients by insurance status (uninsured/Medicaid vs privately insured) and safety-net physicians (seeing >25% uninsured/Medicaid patients) vs non–safety-net physicians (seeing 1%-10%). Main Outcomes and Measures Delivery of 9 low-value or 12 high-value care measures, based on previous research definitions, and composite measures for any high-value or low-value care delivery during an office visit. Results Overall, 193 062 office visits were eligible for at least 1 measure. Mean (95% CI) age for privately insured patients (n = 94 707) was 44.7 (44.5-44.9) years; patients on Medicaid (n = 45 123), 39.8 (39.3-40.3) years; and uninsured patients (n = 19 530), 41.9 (41.5-42.4) years. Overall, low-value and high-value care was delivered in 19.4% (95% CI, 18.5%-20.2%) and 33.4% (95% CI, 32.4%-34.3%) of eligible encounters, respectively. Rates of low-value and high-value care delivery were similar across insurance types for the majority of services examined. Among Medicaid patients, adjusted rates of use were no different for 6 of 9 low-value and 9 of 12 high-value

  3. Quantum Tasks with Non-maximally Quantum Channels via Positive Operator-Valued Measurement

    NASA Astrophysics Data System (ADS)

    Peng, Jia-Yin; Luo, Ming-Xing; Mo, Zhi-Wen

    2013-01-01

    By using a proper positive operator-valued measure (POVM), we present two new schemes for probabilistic transmission with non-maximally four-particle cluster states. In the first scheme, we demonstrate that two non-maximally four-particle cluster states can be used to realize probabilistically sharing an unknown three-particle GHZ-type state within either distant agent's place. In the second protocol, we demonstrate that a non-maximally four-particle cluster state can be used to teleport an arbitrary unknown multi-particle state in a probabilistic manner with appropriate unitary operations and POVM. Moreover the total success probability of these two schemes are also worked out.

  4. Factors influencing the robustness of P-value measurements in CT texture prognosis studies

    NASA Astrophysics Data System (ADS)

    McQuaid, Sarah; Scuffham, James; Alobaidli, Sheaka; Prakash, Vineet; Ezhil, Veni; Nisbet, Andrew; South, Christopher; Evans, Philip

    2017-07-01

    Several studies have recently reported on the value of CT texture analysis in predicting survival, although the topic remains controversial, with further validation needed in order to consolidate the evidence base. The aim of this study was to investigate the effect of varying the input parameters in the Kaplan-Meier analysis, to determine whether the resulting P-value can be considered to be a robust indicator of the parameter’s prognostic potential. A retrospective analysis of the CT-based normalised entropy of 51 patients with lung cancer was performed and overall survival data for these patients were collected. A normalised entropy cut-off was chosen to split the patient cohort into two groups and log-rank testing was performed to assess the survival difference of the two groups. This was repeated for varying normalised entropy cut-offs and varying follow-up periods. Our findings were also compared with previously published results to assess robustness of this parameter in a multi-centre patient cohort. The P-value was found to be highly sensitive to the choice of cut-off value, with small changes in cut-off producing substantial changes in P. The P-value was also sensitive to follow-up period, with particularly noisy results at short follow-up periods. Using matched conditions to previously published results, a P-value of 0.162 was obtained. Survival analysis results can be highly sensitive to the choice in texture cut-off value in dichotomising patients, which should be taken into account when performing such studies to avoid reporting false positive results. Short follow-up periods also produce unstable results and should therefore be avoided to ensure the results produced are reproducible. Previously published findings that indicated the prognostic value of normalised entropy were not replicated here, but further studies with larger patient numbers would be required to determine the cause of the different outcomes.

  5. Challenges in Measuring Cost and Value in Oncology: Making It Personal.

    PubMed

    Yu, Peter P

    2016-01-01

    Oncology patients often find themselves facing an incurable disease with limited treatment options and increasing patient fragility. The importance of patient preferences and values increases in shared decision making especially when the cost of cancer care is continuing its steep rise. As our understanding of cancer systems biology increases, we are justifiably optimistic about therapeutic improvements but recognize that this has complicated the traditional Food and Drug Administration approval of drug indications based on organ-specific cancer for a particular drug. Dynamic and agile clinical guidelines that reflect a rapidly changing knowledge base for decision-making support are needed. The American Society of Clinical Oncology (ASCO) has been working on three initiatives to tackle these complex issues. The first initiative is ASCO's collaboration with other international organizations to create a framework to assess drugs for the World Health Organization's Essential Medicines List, including nongenerics. The second initiative aims to define clinically meaningful outcomes as precision medicine expands the definition of cancers, leading to increased demand for the use of targeted drugs as single agents or in combination. The third initiative is ASCO's value framework, published in 2015, focusing on patient-physician shared decision making. The framework incorporates three parameters: 1) the meaningfulness of the clinical benefit, 2) the toxicity of the treatment, and 3) the patient's financial out-of-pocket cost. ASCO is concerned about the rising cost of cancer care when the clinical complexity and the pace of change in oncology are accelerating, and it is committed to help improve patient outcomes and value in cancer care as well as to engage the broader health care community in a process of collaborative improvement. Copyright © 2016 International Society for Pharmacoeconomics and Outcomes Research (ISPOR). Published by Elsevier Inc. All rights reserved.

  6. Most Wired 2006: measuring value.

    PubMed

    Solovy, Alden

    2006-07-01

    As the Most Wired hospitals incorporate information technology into their strategic plans, they combine a"balanced scorecard"approach with classic business analytics to measure how well IT delivers on their goals. To find out which organizations made this year's 100 Most Wired list, as well as those named in other survey categories, go to the foldout section.

  7. Non-invasive continuous blood pressure measurement based on mean impact value method, BP neural network, and genetic algorithm.

    PubMed

    Tan, Xia; Ji, Zhong; Zhang, Yadan

    2018-04-25

    Non-invasive continuous blood pressure monitoring can provide an important reference and guidance for doctors wishing to analyze the physiological and pathological status of patients and to prevent and diagnose cardiovascular diseases in the clinical setting. Therefore, it is very important to explore a more accurate method of non-invasive continuous blood pressure measurement. To address the shortcomings of existing blood pressure measurement models based on pulse wave transit time or pulse wave parameters, a new method of non-invasive continuous blood pressure measurement - the GA-MIV-BP neural network model - is presented. The mean impact value (MIV) method is used to select the factors that greatly influence blood pressure from the extracted pulse wave transit time and pulse wave parameters. These factors are used as inputs, and the actual blood pressure values as outputs, to train the BP neural network model. The individual parameters are then optimized using a genetic algorithm (GA) to establish the GA-MIV-BP neural network model. Bland-Altman consistency analysis indicated that the measured and predicted blood pressure values were consistent and interchangeable. Therefore, this algorithm is of great significance to promote the clinical application of a non-invasive continuous blood pressure monitoring method.

  8. [Clinical auxiliary diagnosis value of high frequency ultrasonographic measurements of the thickness of transverse carpal ligaments in carpal tunnel syndrome patients].

    PubMed

    Xu, L; Chen, F M; Wang, L; Zhang, P X; Jiang, X R

    2016-04-18

    To evaluate the meaning and value of high-frequency ultrasound in the diagnosis of carpal tunnel syndrome (CTS). In this study, 48 patients (unilateral hand) with CTS were analyzed. The thickness of transverse carpal ligaments at the pisiform bone was measured using high-frequency ultrasound. Open carpal tunnel release procedure was performed in the 48 CTS patients, and the thickness of transverse carpal ligaments at the hamate hook bone measured using vernier caliper under direct vision. The accuracy of thickness of transverse carpal ligaments was evaluated using high-frequency ultrasound. high-frequency ultrasound measurement of thickness of transverse carpal ligaments at the hamate hook bone and pisiform bone, and determination of the diagnostic threshold measurement index using receiver operating characteristic (ROC) curve, sensitivity and specificity were performed and the correlation between the thickness of transverse carpal ligaments and nerve conduction study (NCS) analyzed. The thickness of transverse carpal ligaments in the CTS patients were (0.42±0.08) cm (high-frequency ultrasound) and (0.41±0.06) cm (operation) at hamate hook bone, and there was no significant difference between the two ways (t=0.672, P>0.05). The optimal cut-off value of the transverse carpal ligaments at hamate hook bone was 0.385 cm, the sensitivity 0.775, and the specificity 0.788. The optimal cut-off value of the transverse carpal ligaments at the pisiform bone was 0.315 cm, the sensitivity 0.950, and the specificity 1.000. The transverse carpal ligaments thickness and wrist-index finger sensory nerve conduction velocity (SCV), wrist-middle finger SCV showed a negative correlation. High frequency ultrasound measurements of thickness of transverse carpal ligaments is a valuable method for the diagnosis of CTS.

  9. On the value-dependence of value-driven attentional capture.

    PubMed

    Anderson, Brian A; Halpern, Madeline

    2017-05-01

    Findings from an increasingly large number of studies have been used to argue that attentional capture can be dependent on the learned value of a stimulus, or value-driven. However, under certain circumstances attention can be biased to select stimuli that previously served as targets, independent of reward history. Value-driven attentional capture, as studied using the training phase-test phase design introduced by Anderson and colleagues, is widely presumed to reflect the combined influence of learned value and selection history. However, the degree to which attentional capture is at all dependent on value learning in this paradigm has recently been questioned. Support for value-dependence can be provided through one of two means: (1) greater attentional capture by prior targets following rewarded training than following unrewarded training, and (2) greater attentional capture by prior targets previously associated with high compared to low value. Using a variant of the original value-driven attentional capture paradigm, Sha and Jiang (Attention, Perception, and Psychophysics, 78, 403-414, 2016) failed to find evidence of either, and raised criticisms regarding the adequacy of evidence provided by prior studies using this particular paradigm. To address this disparity, here we provided a stringent test of the value-dependence hypothesis using the traditional value-driven attentional capture paradigm. With a sufficiently large sample size, value-dependence was observed based on both criteria, with no evidence of attentional capture without rewards during training. Our findings support the validity of the traditional value-driven attentional capture paradigm in measuring what its name purports to measure.

  10. On the Value-Dependence of Value-Driven Attentional Capture

    PubMed Central

    Anderson, Brian A.; Halpern, Madeline

    2017-01-01

    Findings from an increasingly large number of studies have been used to argue that attentional capture can be dependent on the learned value of a stimulus, or value-driven. However, under certain circumstances attention can be biased to select stimuli that previously served as targets, independent of reward history. Value-driven attentional capture, as studied using the training phase-test phase design introduced by Anderson and colleagues, is widely presumed to reflect the combined influence of learned value and selection history. However, the degree to which attentional capture is at all dependent on value learning in this paradigm has recently been questioned. Support for value-dependence can be provided through one of two means: (1) greater attentional capture by prior targets following rewarded training than following unrewarded training, and (2) greater attentional capture by prior targets previously associated with high compared to low value. Using a variant of the original value-driven attentional capture paradigm, Sha and Jiang (2016) failed to find evidence of either, and raised criticisms regarding the adequacy of evidence provided by prior studies using this particular paradigm. To address this disparity, here we provided a stringent test of the value-dependence hypothesis using the traditional value-driven attentional capture paradigm. With a sufficiently large sample size, value-dependence was observed based on both criteria, with no evidence of attentional capture without rewards during training. Our findings support the validity of the traditional value-driven attentional capture paradigm in measuring what its name purports to measure. PMID:28176215

  11. Normative values for optical coherence tomography parameters in healthy children and interexaminer agreement for choroidal thickness measurements.

    PubMed

    Turan, Kadriye Erkan; Sekeroglu, Hande Taylan; Baytaroglu, Ata; Bezci, Figen; Karahan, Sevilay

    2018-01-01

    To (a) determine the normative values for optical coherence tomography (OCT) parameters such as central macular thickness, retinal nerve fiber layer thickness, and choroidal thickness in healthy children; (b) investigate the relationships of these parameters with axial length, central corneal thickness, refractive errors, and intraocular pressure; and (c) determine interexaminer agreement for choroidal thickness measurements. In this cross-sectional study, 120 healthy children aged 8-15 years underwent detailed ophthalmological examination and OCT measurements. Choroidal thickness was measured at three separate locations by two independent examiners. The mean global retinal nerve fiber layer thickness was 98.75 ± 9.45 μm (79.0-121.0). The mean central macular thickness was 232.29 ± 29.37 μm (190.0-376.0). The mean subfoveal choroidal thickness obtained by examiner 1 was 344.38 ± 68.83 μm and that obtained by examiner 2 was 344.04 ± 68.92 μm. Interexaminer agreement was between 99.6%-99.8% for choroidal thickness at three separate locations. Central macular thickness increased with axial length (r=0.245, p=0.007). Choroidal thickness increased with age (r=0.291, p=0.001) and decreased with axial length (r=-0.191, p=0.037). Global retinal nerve fiber layer thickness decreased with axial length (r=-0.247, p=0.007) and increased with central corneal thickness (r=0.208, p=0.022). Global retinal nerve fiber layer thickness positively correlated with choroidal thickness (r=0.354, p<0.001). Global retinal nerve fiber layer thickness (r=0.223, p=0.014) and choroidal thickness (r=0.272, p=0.003) increased with the spherical equivalent (D). Optical coherence tomography parameters showed a wide range of variability in children. Retinal nerve fiber layer thickness, central macular thickness, and choroidal thickness were found to be either inter-related or correlated with age, central corneal thickness, axial length, and refractive errors. Furthermore, manual

  12. Reference values of MRI measurements of the common bile duct and pancreatic duct in children.

    PubMed

    Gwal, Kriti; Bedoya, Maria A; Patel, Neal; Rambhatla, Siri J; Darge, Kassa; Sreedharan, Ram R; Anupindi, Sudha A

    2015-07-01

    Magnetic resonance imaging/cholangiopancreatography (MRI/MRCP) is now an essential imaging modality for the evaluation of biliary and pancreatic pathology in children, but there are no data depicting the normal diameters of the common bile duct (CBD) and pancreatic duct. Recognition of abnormal duct size is important and the increasing use of MRCP necessitates normal MRI measurements. To present normal MRI measurements for the common bile duct and pancreatic duct in children. In this retrospective study we searched all children ages birth to 10 years in our MR urography (MRU) database from 2006 until 2013. We excluded children with a history of hepatobiliary or pancreatic surgery. We stratified 204 children into five age groups and retrospectively measured the CBD and the pancreatic duct on 2-D axial and 3-D coronal T2-weighted sequences. We performed statistical analysis, using logistic and linear regressions to detect the age association of the visibility and size of the duct measurements. We used non-parametric tests to detect gender and imaging plane differences. Our study included 204 children, 106 (52%) boys and 98 (48%) girls, with a median age of 33 months (range 0-119 months). The children were distributed into five age groups. The common bile duct was visible in all children in all age groups. The pancreatic duct was significantly less visible in the youngest children, group 1 (54/67, 80.5%; P = 0.003) than in the oldest children, group 5 (22/22, 100%). In group 2 the pancreatic duct was seen in 19/21 (90.4%), in group 3 52/55 (94.5%), and in group 4 39/39 (100%). All duct measurements increased with age (P < 0.001; r-value > 0.423), and the incremental differences between ages were significant. The measurement variations between the axial and coronal planes were statistically significant (P < 0.001); however these differences were fractions of millimeters. For example, in group 1 the mean coronal measurement of the CBD was 2.1 mm and

  13. When in doubt, seize the day? Security values, prosocial values, and proactivity under ambiguity.

    PubMed

    Grant, Adam M; Rothbard, Nancy P

    2013-09-01

    Researchers have suggested that both ambiguity and values play important roles in shaping employees' proactive behaviors, but have not theoretically or empirically integrated these factors. Drawing on theories of situational strength and values, we propose that ambiguity constitutes a weak situation that strengthens the relationship between the content of employees' values and their proactivity. A field study of 204 employees and their direct supervisors in a water treatment plant provided support for this contingency perspective. Ambiguity moderated the relationship between employees' security and prosocial values and supervisor ratings of proactivity. Under high ambiguity, security values predicted lower proactivity, whereas prosocial values predicted higher proactivity. Under low ambiguity, values were not associated with proactivity. We replicated these findings in a laboratory experiment with 232 participants in which we measured proactivity objectively as initiative taken to correct errors: Participants with strong security values were less proactive, and participants with strong prosocial values were more proactive, but only when performance expectations were ambiguous. We discuss theoretical implications for research on proactivity, values, and ambiguity and uncertainty. PsycINFO Database Record (c) 2013 APA, all rights reserved

  14. Year rather than farming system influences protein utilization and energy value of vegetables when measured in a rat model.

    PubMed

    Jørgensen, Henry; Brandt, Kirsten; Lauridsen, Charlotte

    2008-12-01

    The aim of the study was to measure protein utilization and energy value of dried apple, carrot, kale, pea, and potato prepared for human consumption and grown in 2 consecutive years with 3 different farming systems: (1) low input of fertilizer without pesticides (LIminusP), (2) low input of fertilizers and high input of pesticides (LIplusP), (3) and high input of fertilizers and high input of pesticides (HIplusP). In addition, the study goal was to verify the nutritional values, taking into consideration the physiologic state. In experiment 1, the nutritive values, including protein digestibility-corrected amino acid score, were determined in single ingredients in trials with young rats (3-4 weeks) as recommended by the Food and Agriculture Organization of the United Nations/World Health Organization for all age groups. A second experiment was carried out with adult rats to assess the usefulness of digestibility values to predict the digestibility and nutritive value of mixed diets and study the age aspect. Each plant material was included in the diet with protein-free basal mixtures or casein to contain 10% dietary protein. The results showed that variations in protein utilization and energy value determined on single ingredients between cultivation strategies were inconsistent and smaller than between harvest years. Overall, dietary crude fiber was negatively correlated with energy digestibility. The energy value of apple, kale, and pea was lower than expected from literature values. A mixture of plant ingredients fed to adult rats showed lower protein digestibility and higher energy digestibility than predicted. The protein digestibility data obtained using young rats in the calculation of protein digestibility-corrected amino acid score overestimates protein digestibility and quality and underestimates energy value for mature rats. The present study provides new data on protein utilization and energy digestibility of some typical plant foods that may

  15. Resolving Some Issues in Using Value-Added Measures of Productivity for School and Teacher Incentives: Ideas from Technical Assistance and TIF Grantee Experience. The Harvesting Project

    ERIC Educational Resources Information Center

    Milanowski, Anthony

    2011-01-01

    Although many researchers and policy analysts (e.g., Harris, Glazerman et al., 2011; 2010) consider value-added to be the state of the art in school and teacher productivity measurement, only a minority of Teacher Incentive Fund (TIF) Round 1 and 2 grantees used value-added as a measure of school or teacher performance. Fourteen of the 34 grantees…

  16. Congruence and functions of personal and cultural values: do my values reflect my culture's values?

    PubMed

    Fischer, Ronald

    2006-11-01

    Two studies are described examining the correlation between self- and culture-referenced values at a culture level (Study 1) and correlation between self- and culture-referenced values and self-reported behavior at an individual level (Study 2). It is found that values related to individual-group relationships (embeddedness) and expression and experience of affective feelings and emotions (affective autonomy) are significantly correlated at a culture level. In Study 2, culture-referenced values are shown to correlate with behaviors attached to social norms, whereas self-rated values are found to correlate with behaviors that are not norm-governed. Implications for measurement of cultural values and cultural and cross-cultural research designs are discussed.

  17. Higher Environmental Relative Moldiness Index (ERMI) Values Measured in Homes of Asthmatic Children in Boston, Kansas City, and San Diego

    PubMed Central

    Vesper, Stephen; Barnes, Charles; Ciaccio, Christina E.; Johanns, Alan; Kennedy, Kevin; Murphy, Johnna S.; Nunez-Alvarez, Arcela; Sandel, Megan T.; Cox, David; Dewalt, Gary; Ashley, Peter J.

    2013-01-01

    Objective Mold in water-damaged homes has been linked to asthma. Our objective was to test a new metric to quantify mold exposures in asthmatic children’s homes in three widely dispersed cities in the United States. Methods The Environmental Relative Moldiness Index (ERMI) metric was created by the US Environmental Protection Agency, with assistance by the Department of Housing and Urban Development (HUD), to quantify mold contamination in US homes. The ERMI values in homes of asthmatic children were determined for the three widely dispersed cities of Boston, Kansas City, and San Diego. Results Asthmatic children in Boston (n = 76), Kansas City (n = 60), and San Diego (n = 93) were found to be living in homes with significantly higher ERMI values than were found in homes randomly selected during the 2006 HUD American Healthy Homes Survey (AHHS) from the same geographic areas (n = 34, 22, and 28, respectively). Taken together, the average ERMI value in the homes with an asthmatic child was 8.73 compared to 3.87 for the AHHS homes. In addition, Kansas City homes of children with “Mild, Moderate, or Severe Persistent Asthma” had average ERMI value of 12.4 compared to 7.9 for homes of children with only “Mild Intermittent Asthma.” Aspergillus niger was the only mold of the 36 tested which was measured in significantly greater concentration in the homes of asthmatic children in all three cities. Conclusion High ERMI values were associated with homes of asthmatic children in three widely dispersed cities in the United States. PMID:23137280

  18. Postselected weak measurement beyond the weak value

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Geszti, Tamas

    2010-04-15

    Closed expressions are derived for the quantum measurement statistics of pre- and postselected Gaussian particle beams. The weakness of the preselection step is shown to compete with the nonorthogonality of postselection in a transparent way. The approach is shown to be useful in analyzing postselection-based signal amplification, allowing measurements to be extended far beyond the range of validity of the well-known Aharonov-Albert-Vaidman limit. Additionally, the present treatment connects postselected weak measurement to the topic of phase-contrast microscopy.

  19. [Effect of non-genetically modified (non-GM) soy varieties on the measured value of GM soy by a quantitative PCR method].

    PubMed

    Watanabe, Takahiro; Sekino, Ayako; Shiramasa, Yuko; Matsuda, Rieko; Maitani, Tamio

    2008-08-01

    It is very important to examine the effect of non-genetically modified (non-GM) soy varieties, which constitute the matrix of the testing sample used to quantify GM soy (RRS), on the measured value of RRS by quantitative PCR methods. Therefore, we quantified the amount of RRS in powder-mixed samples containing 1 or 5% RRS prepared by using 10 different varieties of non-GM soy as the matrix. The results revealed that the measured values were not in agreement with the powder-mixing levels and that the extent of the difference depended on the variety of non-GM soy used as the matrix. The yields of DNA extracted differed among the soy varieties. On the other hand, analysis of DNA-mixed samples, that were prepared with the DNAs extracted from RRS and non-GM soy varieties, showed that the measured values of RRS were in agreement with the DNA-mixing levels. These results strongly suggest that the proportions of DNA derived from RRS and non-GM soy were not consistent with the powder-mixing ratio in the case of some non-GM soy varieties used as a matrix, resulting in the discrepancy between the measured values and the powder-mixing levels.

  20. Critical laboratory values in hemostasis: toward consensus.

    PubMed

    Lippi, Giuseppe; Adcock, Dorothy; Simundic, Ana-Maria; Tripodi, Armando; Favaloro, Emmanuel J

    2017-09-01

    The term "critical values" can be defined to entail laboratory test results that significantly lie outside the normal (reference) range and necessitate immediate reporting to safeguard patient health, as well as those displaying a highly and clinically significant variation compared to previous data. The identification and effective communication of "highly pathological" values has engaged the minds of many clinicians, health care and laboratory professionals for decades, since these activities are vital to good laboratory practice. This is especially true in hemostasis, where a timely and efficient communication of critical values strongly impacts patient management. Due to the heterogeneity of available data, this paper is hence aimed to analyze the state of the art and provide an expert opinion about the parameters, measurement units and alert limits pertaining to critical values in hemostasis, thus providing a basic document for future consultation that assists laboratory professionals and clinicians alike. KEY MESSAGES Critical values are laboratory test results significantly lying outside the normal (reference) range and necessitating immediate reporting to safeguard patient health. A broad heterogeneity exists about critical values in hemostasis worldwide. We provide here an expert opinion about the parameters, measurement units and alert limits pertaining to critical values in hemostasis.

  1. Measurement of susceptibility artifacts with histogram-based reference value on magnetic resonance images according to standard ASTM F2119.

    PubMed

    Heinrich, Andreas; Teichgräber, Ulf K; Güttler, Felix V

    2015-12-01

    The standard ASTM F2119 describes a test method for measuring the size of a susceptibility artifact based on the example of a passive implant. A pixel in an image is considered to be a part of an image artifact if the intensity is changed by at least 30% in the presence of a test object, compared to a reference image in which the test object is absent (reference value). The aim of this paper is to simplify and accelerate the test method using a histogram-based reference value. Four test objects were scanned parallel and perpendicular to the main magnetic field, and the largest susceptibility artifacts were measured using two methods of reference value determination (reference image-based and histogram-based reference value). The results between both methods were compared using the Mann-Whitney U-test. The difference between both reference values was 42.35 ± 23.66. The difference of artifact size was 0.64 ± 0.69 mm. The artifact sizes of both methods did not show significant differences; the p-value of the Mann-Whitney U-test was between 0.710 and 0.521. A standard-conform method for a rapid, objective, and reproducible evaluation of susceptibility artifacts could be implemented. The result of the histogram-based method does not significantly differ from the ASTM-conform method.

  2. NASA/DOD Aerospace Knowledge Diffusion Research Project. XXIV - A general approach to measuring the value of aerospace information products and services

    NASA Technical Reports Server (NTRS)

    Brinberg, Herbert R.; Pinelli, Thomas E.

    1993-01-01

    This paper discusses the various approaches to measuring the value of information, first defining the meanings of information, economics of information, and value. It concludes that no general model of measuring the value of information is possible and that the usual approaches, such as cost/benefit equations, have very limited applications. It also concludes that in specific contexts with given goals for newly developed products and services or newly acquired information, there is a basis for its objective valuation. The axioms and inputs for such a model are described and directions for further verification and analysis are proposed.

  3. Precision half-life measurement of 11C: The most precise mirror transition F t value

    NASA Astrophysics Data System (ADS)

    Valverde, A. A.; Brodeur, M.; Ahn, T.; Allen, J.; Bardayan, D. W.; Becchetti, F. D.; Blankstein, D.; Brown, G.; Burdette, D. P.; Frentz, B.; Gilardy, G.; Hall, M. R.; King, S.; Kolata, J. J.; Long, J.; Macon, K. T.; Nelson, A.; O'Malley, P. D.; Skulski, M.; Strauss, S. Y.; Vande Kolk, B.

    2018-03-01

    Background: The precise determination of the F t value in T =1 /2 mixed mirror decays is an important avenue for testing the standard model of the electroweak interaction through the determination of Vu d in nuclear β decays. 11C is an interesting case, as its low mass and small QE C value make it particularly sensitive to violations of the conserved vector current hypothesis. The present dominant source of uncertainty in the 11CF t value is the half-life. Purpose: A high-precision measurement of the 11C half-life was performed, and a new world average half-life was calculated. Method: 11C was created by transfer reactions and separated using the TwinSol facility at the Nuclear Science Laboratory at the University of Notre Dame. It was then implanted into a tantalum foil, and β counting was used to determine the half-life. Results: The new half-life, t1 /2=1220.27 (26 ) s, is consistent with the previous values but significantly more precise. A new world average was calculated, t1/2 world=1220.41 (32 ) s, and a new estimate for the Gamow-Teller to Fermi mixing ratio ρ is presented along with standard model correlation parameters. Conclusions: The new 11C world average half-life allows the calculation of a F tmirror value that is now the most precise value for all superallowed mixed mirror transitions. This gives a strong impetus for an experimental determination of ρ , to allow for the determination of Vu d from this decay.

  4. A comparison of daily water use estimates derived from constant-heat sap-flow probe values and gravimetric measurements in pot-grown saplings.

    PubMed

    McCulloh, Katherine A; Winter, Klaus; Meinzer, Frederick C; Garcia, Milton; Aranda, Jorge; Lachenbruch, Barbara

    2007-09-01

    Use of Granier-style heat dissipation sensors to measure sap flow is common in plant physiology, ecology and hydrology. There has been concern that any change to the original Granier design invalidates the empirical relationship between sap flux density and the temperature difference between the probes. Here, we compared daily water use estimates from gravimetric measurements with values from variable length heat dissipation sensors, which are a relatively new design. Values recorded during a one-week period were compared for three large pot-grown saplings of each of the tropical trees Pseudobombax septenatum (Jacq.) Dugand and Calophyllum longifolium Willd. For five of the six individuals, P values from paired t-tests comparing the two methods ranged from 0.12 to 0.43 and differences in estimates of total daily water use over the week of the experiment averaged < 3%. In one P. septenatum sapling, the sap flow sensors underestimated water use relative to the gravimetric measurements. This discrepancy could have been associated with naturally occurring gradients in temperature that reduced the difference in temperature between the probes, which would have caused the sensor method to underestimate water use. Our results indicate that substitution of variable length heat dissipation probes for probes of the original Granier design did not invalidate the empirical relationship determined by Granier between sap flux density and the temperature difference between probes.

  5. Measuring the incentive value of escalating doses of heroin in heroin-dependent Fischer rats during acute spontaneous withdrawal

    PubMed Central

    Reed, Brian; Ho, Ann; Kreek, Mary Jeanne

    2011-01-01

    Rationale/objectives Although continued heroin use and relapse are thought to be motivated, in part, by the positive incentive-motivational value attributed to heroin, little is understood about heroin’s incentive value during the relapse-prone state of withdrawal. This study uses place preference to measure the incentive value attributed to escalating-dose heroin in the context of heroin dependence. Methods Male Fischer rats were exposed chronically to escalating doses of heroin in the homecage and during place preference conditioning sessions. Conditioned preference for the context paired with escalating-dose heroin was tested after homecage exposure was discontinued and rats entered acute spontaneous withdrawal. Individuals’ behavioral and locomotor responses to heroin and somatic withdrawal signs were recorded. Results Conditioned preference for the heroin-paired context was strong in rats that received chronic homecage exposure to escalating-dose heroin and were tested in acute withdrawal. Behavioral responses to heroin (e.g., stereotypy) varied widely across individuals, with rats that expressed stronger heroin preference also expressing stronger behavioral activation in response to heroin. Individual differences in preference were also related to locomotor responses to heroin but not to overt somatic withdrawal signs. Conclusions Escalating doses of heroin evoked place preference in rats, suggesting that positive incentive-motivational value is attributed to this clinically relevant pattern of drug exposure. This study offers an improved preclinical model for studying dependence and withdrawal and provides insight into individual vulnerabilities to addiction-like behavior. PMID:21748254

  6. The predictive value of quantitative fibronectin testing in combination with cervical length measurement in symptomatic women.

    PubMed

    Bruijn, Merel M C; Kamphuis, Esme I; Hoesli, Irene M; Martinez de Tejada, Begoña; Loccufier, Anne R; Kühnert, Maritta; Helmer, Hanns; Franz, Marie; Porath, Martina M; Oudijk, Martijn A; Jacquemyn, Yves; Schulzke, Sven M; Vetter, Grit; Hoste, Griet; Vis, Jolande Y; Kok, Marjolein; Mol, Ben W J; van Baaren, Gert-Jan

    2016-12-01

    The combination of the qualitative fetal fibronectin test and cervical length measurement has a high negative predictive value for preterm birth within 7 days; however, positive prediction is poor. A new bedside quantitative fetal fibronectin test showed potential additional value over the conventional qualitative test, but there is limited evidence on the combination with cervical length measurement. The purpose of this study was to compare quantitative fetal fibronectin and qualitative fetal fibronectin testing in the prediction of spontaneous preterm birth within 7 days in symptomatic women who undergo cervical length measurement. We performed a European multicenter cohort study in 10 perinatal centers in 5 countries. Women between 24 and 34 weeks of gestation with signs of active labor and intact membranes underwent quantitative fibronectin testing and cervical length measurement. We assessed the risk of preterm birth within 7 days in predefined strata based on fibronectin concentration and cervical length. Of 455 women who were included in the study, 48 women (11%) delivered within 7 days. A combination of cervical length and qualitative fibronectin resulted in the identification of 246 women who were at low risk: 164 women with a cervix between 15 and 30 mm and a negative fibronectin test (<50 ng/mL; preterm birth rate, 2%) and 82 women with a cervix at >30 mm (preterm birth rate, 2%). Use of quantitative fibronectin alone resulted in a predicted risk of preterm birth within 7 days that ranged from 2% in the group with the lowest fibronectin level (<10 ng/mL) to 38% in the group with the highest fibronectin level (>500 ng/mL), with similar accuracy as that of the combination of cervical length and qualitative fibronectin. Combining cervical length and quantitative fibronectin resulted in the identification of an additional 19 women at low risk (preterm birth rate, 5%), using a threshold of 10 ng/mL in women with a cervix at <15 mm, and 6 women at high risk

  7. Measurement of pulmonary transit time in healthy cats by use of ultrasound contrast media "Sonovue®": feasibility, reproducibility, and values in 42 cats.

    PubMed

    Streitberger, Andrea; Hocke, Verena; Modler, Peter

    2013-09-01

    To evaluate the feasibility of measuring pulmonary transit time (PTT) in healthy cats by transthoracic echocardiography using the ultrasound contrast agent Sonovue(®). To determine normalized PTT (nPTT) values in 42 healthy cats and to estimate the interobserver variability and the within-day repeatability of nPTT measurements. Forty-two privately owned healthy cats of different breeds, gender and age presented for cardiac examination. A bolus injection of contrast agent (Sonovue(®)) was administered intravenously. The right parasternal short axis echocardiographic view was used to record the contrast agent's transit time from the pulmonary artery to the left atrium. Pulmonary transit time and nPTT were determined independently by three examiners with different levels of experience. Normalized PTT was 4.12 ± 1.0 (mean ± SD) in our population. The median interobserver variability across our population was 6.8%, the median within-day variability for the three observers were 13.1%, 12.7% and 13%. No effect of the observer's experience on nPTT measurement was identified. Age, sex and body weight did not significantly influence nPTT. This study demonstrates that nPTT measurement is feasible in cats using ultrasound and the blood pool contrast media Sonovue(®). Measurements of nPTT can be performed in a clinical setting. Normalized PTT values in healthy cats are comparable with those reported in healthy dogs. Copyright © 2013 Elsevier B.V. All rights reserved.

  8. Reference values of MostGraph measures for middle-aged and elderly Japanese individuals who participated in annual health checkups.

    PubMed

    Abe, Yuki; Shibata, Yoko; Igarashi, Akira; Inoue, Sumito; Sato, Kento; Sato, Masamichi; Nemoto, Takako; Kobayashi, Maki; Nishiwaki, Michiko; Kimura, Tomomi; Tokairin, Yoshikane; Kayama, Takamasa; Kubota, Isao

    2016-05-01

    The forced oscillation technique (FOT) can measure respiratory system resistance and reactance under tidal volume respiration. MostGraph is a device that incorporates the FOT and enables the immediate, three-dimensional visualization of resistance and reactance parameters. The aim of this study was to establish MostGraph reference values for middle-aged and elderly Japanese individuals. From 2004 to 2006, 3253 subjects living in Takahata, Yamagata underwent spirometry. Of these, 872 again underwent spirometry in 2011, and 784 (368 men, ages 46-89 years; 416 women, ages 47-90 years) underwent FOT examinations using MostGraph-01. In this study population, 19.0% of the men and 91.5% of the women were life-long never smokers. Abnormal spirometric findings were observed in 30.2% of the men and 14.6% of the women. Although the respiratory system resistance and reactance parameters obtained using MostGraph were not distributed normally, normal distribution was achieved via natural logarithm (R5, R20, Fres, and ALX), square root (R5-R20), or exponential (X5) transformation. Furthermore, the transformed values were converted back to the actual values after determining the values representing one and two standard deviations from the mean. Respiratory system resistance and reactance reference values were determined using MostGraph in middle-aged and elderly Japanese individuals who participated in annual health checkups. Copyright © 2016 The Japanese Respiratory Society. Published by Elsevier B.V. All rights reserved.

  9. Values in Education and Education in Values.

    ERIC Educational Resources Information Center

    Halstead, J. Mark, Ed.; Taylor, Monica J., Ed.

    The major purpose of this book is to set out some of the key issues and debates relating to the importance of values in education and of education in values. After an introductory chapter about the concept of values and values education, part 1 provides a variety of perspectives on the values that underpin contemporary education. The introduction…

  10. Incremental Value of Repeated Risk Factor Measurements for Cardiovascular Disease Prediction in Middle-Aged Korean Adults: Results From the NHIS-HEALS (National Health Insurance System-National Health Screening Cohort).

    PubMed

    Cho, In-Jeong; Sung, Ji Min; Chang, Hyuk-Jae; Chung, Namsik; Kim, Hyeon Chang

    2017-11-01

    Increasing evidence suggests that repeatedly measured cardiovascular disease (CVD) risk factors may have an additive predictive value compared with single measured levels. Thus, we evaluated the incremental predictive value of incorporating periodic health screening data for CVD prediction in a large nationwide cohort with periodic health screening tests. A total of 467 708 persons aged 40 to 79 years and free from CVD were randomly divided into development (70%) and validation subcohorts (30%). We developed 3 different CVD prediction models: a single measure model using single time point screening data; a longitudinal average model using average risk factor values from periodic screening data; and a longitudinal summary model using average values and the variability of risk factors. The development subcohort included 327 396 persons who had 3.2 health screenings on average and 25 765 cases of CVD over 12 years. The C statistics (95% confidence interval [CI]) for the single measure, longitudinal average, and longitudinal summary models were 0.690 (95% CI, 0.682-0.698), 0.695 (95% CI, 0.687-0.703), and 0.752 (95% CI, 0.744-0.760) in men and 0.732 (95% CI, 0.722-0.742), 0.735 (95% CI, 0.725-0.745), and 0.790 (95% CI, 0.780-0.800) in women, respectively. The net reclassification index from the single measure model to the longitudinal average model was 1.78% in men and 1.33% in women, and the index from the longitudinal average model to the longitudinal summary model was 32.71% in men and 34.98% in women. Using averages of repeatedly measured risk factor values modestly improves CVD predictability compared with single measurement values. Incorporating the average and variability information of repeated measurements can lead to great improvements in disease prediction. URL: https://www.clinicaltrials.gov. Unique identifier: NCT02931500. © 2017 American Heart Association, Inc.

  11. How weak values emerge in joint measurements on cloned quantum systems.

    PubMed

    Hofmann, Holger F

    2012-07-13

    A statistical analysis of optimal universal cloning shows that it is possible to identify an ideal (but nonpositive) copying process that faithfully maps all properties of the original Hilbert space onto two separate quantum systems, resulting in perfect correlations for all observables. The joint probabilities for noncommuting measurements on separate clones then correspond to the real parts of the complex joint probabilities observed in weak measurements on a single system, where the measurements on the two clones replace the corresponding sequence of weak measurement and postselection. The imaginary parts of weak measurement statics can be obtained by replacing the cloning process with a partial swap operation. A controlled-swap operation combines both processes, making the complete weak measurement statistics accessible as a well-defined contribution to the joint probabilities of fully resolved projective measurements on the two output systems.

  12. Children's Perceived Competence Scale: Reference values in Japan.

    PubMed

    Nagai, Yukiyo; Nomura, Kayo; Nagata, Masako; Ohgi, Shohei; Iwasa, Mitsuji

    2015-12-01

    To support children with chronic diseases, reference values to measure developmental changes in self-perception and self-esteem are considered a useful yardstick. To develop reference values to measure self-perceived competence and self-esteem in Japanese children, the Children's Perceived Competence Scale (CPCS) was administered to 768 children of elementary school grade 1 (6 years) to grade 6 (11 years) at four public schools in Japan, from November to December 2012. After excluding 74 with chronic diseases and/or incomplete responses, 694 children were included. CPCS measures children's self-perceived competence in cognitive, social, physical domains, and general self-worth, namely self-esteem. There was a tendency for scores of cognitive and general self-worth to decrease with increasing grade. Scores among grade 5 respondents were significantly lower than those among grade 4 respondents for both social and physical domains. Scores among boys and girls differed significantly, with boys scoring higher for physical domain in grades 3 and 6 and for general self-worth domain in grade 6. The CPCS reference values to measure self-perceived competence and self-esteem in Japanese children were developed in this study. These reference values are useful to inform practitioners supporting children with psychological or psychiatric problems or those with chronic diseases. © The Author(s) 2014.

  13. The Measurement of Subjective Value and Its Relation to Contingent Valuation and Environmental Public Goods

    PubMed Central

    Khaw, Mel W.; Grab, Denise A.; Livermore, Michael A.; Vossler, Christian A.; Glimcher, Paul W.

    2015-01-01

    Environmental public goods—including national parks, clean air/water, and ecosystem services—provide substantial benefits on a global scale. These goods have unique characteristics in that they are typically “nonmarket” goods, with values from both use and passive use that accrue to a large number of individuals both in current and future generations. In this study, we test the hypothesis that neural signals in areas correlated with subjective valuations for essentially all other previously studied categories of goods (ventromedial prefrontal cortex and ventral striatum) also correlate with environmental valuations. We use contingent valuation (CV) as our behavioral tool for measuring valuations of environmental public goods. CV is a standard stated preference approach that presents survey respondents with information on an issue and asks questions that help policymakers determine how much citizens are willing to pay for a public good or policy. We scanned human subjects while they viewed environmental proposals, along with three other classes of goods. The presentation of all four classes of goods yielded robust and similar patterns of temporally synchronized brain activation within attentional networks. The activations associated with the traditional classes of goods replicate previous correlations between neural activity in valuation areas and behavioral preferences. In contrast, CV-elicited values for environmental proposals did not correlate with brain activity at either the individual or population level. For a sub-population of participants, CV-elicited values were correlated with activity within the dorsomedial prefrontal cortex, a region associated with cognitive control and shifting decision strategies. The results show that neural activity associated with the subjective valuation of environmental proposals differs profoundly from the neural activity associated with previously examined goods and preference measures. PMID:26221734

  14. Apparent diffusion coefficient measurement in glioma: Influence of region-of-interest determination methods on apparent diffusion coefficient values, interobserver variability, time efficiency, and diagnostic ability.

    PubMed

    Han, Xu; Suo, Shiteng; Sun, Yawen; Zu, Jinyan; Qu, Jianxun; Zhou, Yan; Chen, Zengai; Xu, Jianrong

    2017-03-01

    To compare four methods of region-of-interest (ROI) placement for apparent diffusion coefficient (ADC) measurements in distinguishing low-grade gliomas (LGGs) from high-grade gliomas (HGGs). Two independent readers measured ADC parameters using four ROI methods (single-slice [single-round, five-round and freehand] and whole-volume) on 43 patients (20 LGGs, 23 HGGs) who had undergone 3.0 Tesla diffusion-weighted imaging and time required for each method of ADC measurements was recorded. Intraclass correlation coefficients (ICCs) were used to assess interobserver variability of ADC measurements. Mean and minimum ADC values and time required were compared using paired Student's t-tests. All ADC parameters (mean/minimum ADC values of three single-slice methods, mean/minimum/standard deviation/skewness/kurtosis/the10 th and 25 th percentiles/median/maximum of whole-volume method) were correlated with tumor grade (low versus high) by unpaired Student's t-tests. Discriminative ability was determined by receiver operating characteristic curves. All ADC measurements except minimum, skewness, and kurtosis of whole-volume ROI differed significantly between LGGs and HGGs (all P < 0.05). Mean ADC value of single-round ROI had the highest effect size (0.72) and the greatest areas under the curve (0.872). Three single-slice methods had good to excellent ICCs (0.67-0.89) and the whole-volume method fair to excellent ICCs (0.32-0.96). Minimum ADC values differed significantly between whole-volume and single-round ROI (P = 0.003) and, between whole-volume and five-round ROI (P = 0.001). The whole-volume method took significantly longer than all single-slice methods (all P < 0.001). ADC measurements are influenced by ROI determination methods. Whole-volume histogram analysis did not yield better results than single-slice methods and took longer. Mean ADC value derived from single-round ROI is the most optimal parameter for differentiating LGGs from HGGs. 3 J. Magn

  15. The impact of reliable prebolus T 1 measurements or a fixed T 1 value in the assessment of glioma patients with dynamic contrast enhancing MRI.

    PubMed

    Tietze, Anna; Mouridsen, Kim; Mikkelsen, Irene Klærke

    2015-06-01

    Accurate quantification of hemodynamic parameters using dynamic contrast enhanced (DCE) MRI requires a measurement of tissue T 1 prior to contrast injection (T 1). We evaluate (i) T 1 estimation using the variable flip angle (VFA) and the saturation recovery (SR) techniques and (ii) investigate if accurate estimation of DCE parameters outperform a time-saving approach with a predefined T 1 value when differentiating high- from low-grade gliomas. The accuracy and precision of T 1 measurements, acquired by VFA and SR, were investigated by computer simulations and in glioma patients using an equivalence test (p > 0.05 showing significant difference). The permeability measure, K trans, cerebral blood flow (CBF), and - volume, V p, were calculated in 42 glioma patients, using fixed T 1 of 1500 ms or an individual T 1 measurement, using SR. The areas under the receiver operating characteristic curves (AUCs) were used as measures for accuracy to differentiate tumor grade. The T 1 values obtained by VFA showed larger variation compared to those obtained using SR both in the digital phantom and the human data (p > 0.05). Although a fixed T 1 introduced a bias into the DCE calculation, this had only minor impact on the accuracy differentiating high-grade from low-grade gliomas, (AUCfix = 0.906 and AUCind = 0.884 for K trans; AUCfix = 0.863 and AUCind = 0.856 for V p; p for AUC comparison > 0.05). T 1 measurements by VFA were less precise, and the SR method is preferable, when accurate parameter estimation is required. Semiquantitative DCE values, based on predefined T 1 values, were sufficient to perform tumor grading in our study.

  16. The cutoff values of indirect indices for measuring insulin resistance for metabolic syndrome in Korean children and adolescents.

    PubMed

    Kim, Jun Woo; Park, Sang Hoo; Kim, Yoojin; Im, Minji; Han, Heon-Seok

    2016-09-01

    The prevalence rates of metabolic syndrome (MetS) and percentile distribution of insulin resistance (IR) among Korean children and adolescents were investigated. The cutoff values of IR were calculated to identify high-risk MetS groups. Data from 3,313 Korean subjects (1,756 boys and 1,557 girls, aged 10-18 years) were included from the Korean National Health and Nutrition Examination Survey conducted during 2007-2010. Three different sets of criteria for MetS were used. Indirect measures of IR were homeostasis model assessment (HOMA-IR) and triglyceride and glucose (TyG) index. The cutoff values of the HOMA-IR and TyG index were obtained from the receiver operation characteristic curves. According to the MetS criteria of de Ferranti el al., Cook et al., and the International Diabetes Federation, the prevalence rates in males and females were 13.9% and 12.3%, 4.6% and 3.6%, and 1.4% and 1.8%, respectively. Uses these 3 criteria, the cutoff values of the HOMA-IR and TyG index were 2.94 and 8.41, 3.29 and 8.38, and 3.54 and 8.66, respectively. The cutoff values using each of the 3 criteria approximately corresponds to the 50th-75th, 75th, and 75th-90th percentiles of normal HOMA-IR and TyG index levels. This study describes the prevalence rates of MetS in Korean children and adolescents, an index of IR, and the cutoff values for MetS with the aim of detecting high-risk groups. The usefulness of these criteria needs to be verified by further evaluation.

  17. Measurements of exclusive photoproduction processes at large values of t and u from 4 to 7.5 GeV

    USGS Publications Warehouse

    Anderson, R.L.; Gustavson, D.B.; Ritson, D.M.; Weitsch, G.A.; Halpern, H.J.; Prepost, R.; Tompkins, Donald H.; Wiser, D.E.

    1976-01-01

    Exclusive photoproduction cross sections have been measured for the processes p+n, p0p, p-++, p0p, pK+, and pK+0 at large t and u values at several energies for each process between 4 and 7.5 GeV. These measurements taken together with past data taken at small values of t and u provide complete angular distributions. The data show the usual small t and u peaks and a central region in which the cross section decreases approximately as s-7. The results are discussed within the context of parton or constituent models. ?? 1976 The American Physical Society.

  18. The Measurement of Values: Effects of Different Assessment Procedures

    ERIC Educational Resources Information Center

    Feather, N. T.

    1973-01-01

    Rating and pair-comparison procedures for assessing the importance of terminal and instrumental values were compared with the standard ranking procedure developed by Rokeach. Effects of order of presentation of of the value sets were also investigated. Neither procedure nor order had replicable effect though some sex differences were apparent. (TO)

  19. Development of a Singlet Oxygen Absorption Capacity (SOAC) Assay Method. Measurements of the SOAC Values for Carotenoids and α-Tocopherol in an Aqueous Triton X-100 Micellar Solution.

    PubMed

    Mukai, Kazuo; Ouchi, Aya; Azuma, Nagao; Takahashi, Shingo; Aizawa, Koichi; Nagaoka, Shin-Ichi

    2017-02-01

    Recently, a new assay method for the quantification of the singlet oxygen absorption capacity (SOAC) of antioxidants (AOs) and food extracts in homogeneous organic solvents was proposed. In this study, second-order rate constants (k Q ) for the reaction of singlet oxygen ( 1 O 2 ) with eight different carotenoids (Cars) and α-tocopherol (α-Toc) were measured in an aqueous Triton X-100 (5.0 wt %) micellar solution (pH 7.4, 35 °C), which was used as a simple model of biomembranes. The k Q and relative SOAC values were measured using ultraviolet-visible (UV-vis) spectroscopy. The UV-vis absorption spectra of Cars and α-Toc were measured in both a micellar solution and chloroform, to investigate the effect of solvent on the k Q and SOAC values. Furthermore, decay rates (k d ) of 1 O 2 were measured in 0.0, 1.0, 3.0, and 5.0 wt % micellar solutions (pH 7.4), using time-resolved near-infrared fluorescence spectroscopy, to determine the absolute k Q values of the AOs. The results obtained demonstrate that the k Q values of AOs in homogeneous and heterogeneous solutions vary notably depending on (i) the polarity [dielectric constant (ε)] of the reaction field between AOs and 1 O 2 , (ii) the local concentration of AOs, and (iii) the mobility of AOs in solution. In addition, the k Q and relative SOAC values obtained for the Cars in a heterogeneous micellar solution differ remarkably from those in homogeneous organic solvents. Measurements of k Q and SOAC values in a micellar solution may be useful for evaluating the 1 O 2 quenching activity of AOs in biological systems.

  20. Half-life, branching-ratio, and Q-value measurement for the superallowed 0{sup +}{yields}0{sup +}{beta}{sup +} emitter {sup 42}Ti

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Nieto, T. Kurtukian; Souin, J.; Audirac, L.

    2009-09-15

    The half-life, the branching ratio, and the decay Q value of the superallowed {beta} emitter {sup 42}Ti were measured in an experiment performed at the JYFLTRAP facility of the Accelerator Laboratory of the University of Jyvaeskylae. {sup 42}Ti is the heaviest T{sub z}=-1 nucleus for which high-precision measurements of these quantities have been tried. The half-life (T{sub 1/2}=208.14{+-}0.45 ms) and the Q value [Q{sub EC}=7016.83(25) keV] are close to or reach the required precision of about 0.1%. The branching ratio for the superallowed decay branch [BR=47.7(12)%], a by-product of the half-life measurement, does not reach the necessary precision yet. Nonetheless,more » these results allow one to determine the experimental ft value and the corrected Ft value to be 3114(79) and 3122(79) s, respectively.« less

  1. The public health value of vaccines beyond efficacy: methods, measures and outcomes.

    PubMed

    Wilder-Smith, A; Longini, I; Zuber, P L; Bärnighausen, T; Edmunds, W J; Dean, N; Spicher, V Masserey; Benissa, M R; Gessner, B D

    2017-07-26

    Assessments of vaccine efficacy and safety capture only the minimum information needed for regulatory approval, rather than the full public health value of vaccines. Vaccine efficacy provides a measure of proportionate disease reduction, is usually limited to etiologically confirmed disease, and focuses on the direct protection of the vaccinated individual. Herein, we propose a broader scope of methods, measures and outcomes to evaluate the effectiveness and public health impact to be considered for evidence-informed policymaking in both pre- and post-licensure stages. Pre-licensure: Regulatory concerns dictate an individually randomised clinical trial. However, some circumstances (such as the West African Ebola epidemic) may require novel designs that could be considered valid for licensure by regulatory agencies. In addition, protocol-defined analytic plans for these studies should include clinical as well as etiologically confirmed endpoints (e.g. all cause hospitalisations, pneumonias, acute gastroenteritis and others as appropriate to the vaccine target), and should include vaccine-preventable disease incidence and 'number needed to vaccinate' as outcomes. Post-licensure: There is a central role for phase IV cluster randomised clinical trials that allows for estimation of population-level vaccine impact, including indirect, total and overall effects. Dynamic models should be prioritised over static models as the constant force of infection assumed in static models will usually underestimate the effectiveness and cost-effectiveness of the immunisation programme by underestimating indirect effects. The economic impact of vaccinations should incorporate health and non-health benefits of vaccination in both the vaccinated and unvaccinated populations, thus allowing for estimation of the net social value of vaccination. The full benefits of vaccination reach beyond direct prevention of etiologically confirmed disease and often extend across the life course of a

  2. The iMTA Productivity Cost Questionnaire: A Standardized Instrument for Measuring and Valuing Health-Related Productivity Losses.

    PubMed

    Bouwmans, Clazien; Krol, Marieke; Severens, Hans; Koopmanschap, Marc; Brouwer, Werner; Hakkaart-van Roijen, Leona

    2015-09-01

    Productivity losses often contribute significantly to the total costs in economic evaluations adopting a societal perspective. Currently, no consensus exists on the measurement and valuation of productivity losses. We aimed to develop a standardized instrument for measuring and valuing productivity losses. A group of researchers with extensive experience in measuring and valuing productivity losses designed an instrument suitable for self-completion, building on preknowledge and evidence on validity. The instrument was designed to cover all domains of productivity losses, thus allowing quantification and valuation of all productivity losses. A feasibility study was performed to check the questionnaire's consistency and intelligibility. The iMTA Productivity Cost Questionnaire (iPCQ) includes three modules measuring productivity losses of paid work due to 1) absenteeism and 2) presenteeism and productivity losses related to 3) unpaid work. Questions for measuring absenteeism and presenteeism were derived from existing validated questionnaires. Because validated measures of losses of unpaid work are scarce, the questions of this module were newly developed. To enhance the instrument's feasibility, simple language was used. The feasibility study included 195 respondents (response rate 80%) older than 18 years. Seven percent (n = 13) identified problems while filling in the iPCQ, including problems with the questionnaire's instructions and routing (n = 6) and wording (n = 2). Five respondents experienced difficulties in estimating the time that would be needed for other people to make up for lost unpaid work. Most modules of the iPCQ are based on validated questions derived from previously available instruments. The instrument is understandable for most of the general public. Copyright © 2015 International Society for Pharmacoeconomics and Outcomes Research (ISPOR). Published by Elsevier Inc. All rights reserved.

  3. Reference Values of Grip Strength, Prevalence of Low Grip Strength, and Factors Affecting Grip Strength Values in Chinese Adults.

    PubMed

    Yu, Ruby; Ong, Sherlin; Cheung, Osbert; Leung, Jason; Woo, Jean

    2017-06-01

    The objectives of this study were to update the reference values of grip strength, to estimate the prevalence of low grip strength, and to examine the impact of different aspects of measurement protocol on grip strength values in Chinese adults. A cross-sectional survey of Chinese men (n = 714) and women (n = 4014) aged 18-102 years was undertaken in different community settings in Hong Kong. Grip strength was measured with a digital dynamometer (TKK 5401 Grip-D; Takei, Niigata, Japan). Low grip strength was defined as grip strength 2 standard deviations or more below the mean for young adults. The effects of measurement protocol on grip strength values were examined in a subsample of 45 men and women with repeated measures of grip strength taken with a hydraulic dynamometer (Baseline; Fabrication Enterprises Inc, Irvington, NY), using pair t-tests, intraclass correlation coefficient, and Bland and Altman plots. Grip strength was greater among men than among women (P < .001) and the rate of decline differed between sexes (P < .001). The prevalence of low grip strength also increased with age, reaching a rate of 16.5% in men and 20.6% in women aged 65+. Although the TKK digital dynamometer gave higher grip strength values than the Baseline hydraulic dynamometer (P < .001), the degree of agreement between the 2 dynamometers was satisfactory. Higher grip strength values were also observed when the measurement was performed with the elbow extended in a standing position, compared with that with the elbow flexed at 90° in a sitting position, using the same dynamometer (P < .05). This study updated the reference values of grip strength and estimated the prevalence of low grip strength among Chinese adults spanning a wide age range. These findings might be useful for risk estimation and evaluation of interventions. However, grip strength measurements should be interpreted with caution, as grip strength values can be affected by type of dynamometer used

  4. NASA/DOD Aerospace Knowledge Diffusion Research Project. Paper 24: A general approach to measuring the value of aerospace information products and services

    NASA Technical Reports Server (NTRS)

    Brinberg, Herbert R.; Pinelli, Thomas E.

    1993-01-01

    This paper discusses the various approaches to measuring the value of information, first defining the meanings of information, economics of information, and value. It concludes that no general model of measuring the value of information is possible and that the usual approaches, such as cost/benefit equations, have very limited applications. It also concludes that in specific contexts with given goals for newly developed products and services or newly acquired information there is a basis for its objective valuation. The axioms and inputs for such a model are described and directions for further verification and analysis are proposed.

  5. Measuring the Value of the Hubble Constant “à la Refsdal”

    NASA Astrophysics Data System (ADS)

    Grillo, C.; Rosati, P.; Suyu, S. H.; Balestra, I.; Caminha, G. B.; Halkola, A.; Kelly, P. L.; Lombardi, M.; Mercurio, A.; Rodney, S. A.; Treu, T.

    2018-06-01

    Realizing Refsdal’s original idea from 1964, we present estimates of the Hubble constant that are complementary to, and potentially competitive with, those of other cosmological probes. We use the observed positions of 89 multiple images, with extensive spectroscopic information, from 28 background sources and the measured time delays between the images S1–S4 and SX of supernova “Refsdal” (z = 1.489), which were obtained thanks to Hubble Space Telescope deep imaging and Multi Unit Spectroscopic Explorer data. We extend the strong-lensing modeling of the Hubble Frontier Fields galaxy cluster MACS J1149.5+2223 (z = 0.542), published by Grillo et al. (2016), and explore different ΛCDM models. Taking advantage of the lensing information associated to the presence of very close pairs of multiple images at various redshifts, and to the extended surface brightness distribution of the SN Refsdal host, we can reconstruct the total mass-density profile of the cluster very precisely. The combined dependence of the multiple-image positions and time delays on the cosmological parameters allows us to infer the values of H 0 and Ωm with relative (1σ) statistical errors of, respectively, 6% (7%) and 31% (26%) in flat (general) cosmological models, assuming a conservative 3% uncertainty on the final time delay of image SX and, remarkably, no priors from other cosmological experiments. Our best estimate of H 0, based on the model described in this work, will be presented when the final time-delay measurement becomes available. Our results show that it is possible to utilize time delays in lens galaxy clusters as an important alternative tool for measuring the expansion rate and the geometry of the universe.

  6. Measuring the value of older people's production: a diary study

    PubMed Central

    2012-01-01

    Background The productive capacity of retired people is usually not valued. However, some retirees produce much more than we might expect. This diary-based study identifies the activities of older people, and suggests some value mechanisms. One question raised is whether it is possible to scale up this diary study into a larger representative study. Methods Diaries kept for one week were collected among 23 older people in the north of Sweden. The texts were analysed with a grounded theory approach; an interplay between ideas and empirical data. Results Some productive activities of older people must be valued as the opportunity cost of time or according to the market value, and others must be valued with the replacement cost. In order to make the choice between these methods, it is important to consider the societal entitlement. When there is no societal entitlement, the first or second method must be used; and when it exists, the third must be used. Conclusions An explicit investigation of the content of the entitlement is needed to justify the choice of valuation method for each activity. In a questionnaire addressing older people's production, each question must be adjusted to the type of production. In order to fully understand this production, it is important to consider the degree of free choice to conduct an activity, as well as health-related quality of life. PMID:22230745

  7. Inter-Method Reliability of School Effectiveness Measures: A Comparison of Value-Added and Regression Discontinuity Estimates

    ERIC Educational Resources Information Center

    Perry, Thomas

    2017-01-01

    Value-added (VA) measures are currently the predominant approach used to compare the effectiveness of schools. Recent educational effectiveness research, however, has developed alternative approaches including the regression discontinuity (RD) design, which also allows estimation of absolute school effects. Initial research suggests RD is a viable…

  8. Replacing missing values using trustworthy data values from web data sources

    NASA Astrophysics Data System (ADS)

    Izham Jaya, M.; Sidi, Fatimah; Mat Yusof, Sharmila; Suriani Affendey, Lilly; Ishak, Iskandar; Jabar, Marzanah A.

    2017-09-01

    In practice, collected data usually are incomplete and contains missing value. Existing approaches in managing missing values overlook the importance of trustworthy data values in replacing missing values. In view that trusted completed data is very important in data analysis, we proposed a framework of missing value replacement using trustworthy data values from web data sources. The proposed framework adopted ontology to map data values from web data sources to the incomplete dataset. As data from web is conflicting with each other, we proposed a trust score measurement based on data accuracy and data reliability. Trust score is then used to select trustworthy data values from web data sources for missing values replacement. We successfully implemented the proposed framework using financial dataset and presented the findings in this paper. From our experiment, we manage to show that replacing missing values with trustworthy data values is important especially in a case of conflicting data to solve missing values problem.

  9. Optimizing occupational exposure measurement strategies when estimating the log-scale arithmetic mean value--an example from the reinforced plastics industry.

    PubMed

    Lampa, Erik G; Nilsson, Leif; Liljelind, Ingrid E; Bergdahl, Ingvar A

    2006-06-01

    When assessing occupational exposures, repeated measurements are in most cases required. Repeated measurements are more resource intensive than a single measurement, so careful planning of the measurement strategy is necessary to assure that resources are spent wisely. The optimal strategy depends on the objectives of the measurements. Here, two different models of random effects analysis of variance (ANOVA) are proposed for the optimization of measurement strategies by the minimization of the variance of the estimated log-transformed arithmetic mean value of a worker group, i.e. the strategies are optimized for precise estimation of that value. The first model is a one-way random effects ANOVA model. For that model it is shown that the best precision in the estimated mean value is always obtained by including as many workers as possible in the sample while restricting the number of replicates to two or at most three regardless of the size of the variance components. The second model introduces the 'shared temporal variation' which accounts for those random temporal fluctuations of the exposure that the workers have in common. It is shown for that model that the optimal sample allocation depends on the relative sizes of the between-worker component and the shared temporal component, so that if the between-worker component is larger than the shared temporal component more workers should be included in the sample and vice versa. The results are illustrated graphically with an example from the reinforced plastics industry. If there exists a shared temporal variation at a workplace, that variability needs to be accounted for in the sampling design and the more complex model is recommended.

  10. Unconditional reference values for the amniotic fluid index measurement between 26w0d and 41w6d of gestation in low-risk pregnancies.

    PubMed

    Peixoto, Alberto Borges; Caldas, Taciana Mara Rodrigues da Cunha; Martins, Wellington P; Da Silva Costa, Fabricio; Araujo Júnior, Edward

    2016-10-01

    To establish reference values for the amniotic fluid index (AFI) measurement between 26w0d and 41w6d of gestation in a Brazilian population. We performed a cross-sectional study with 1984 low-risk singleton pregnant women between 26w0d and 41w6d of gestation. AFI was measured according to the technique proposed by Phelan et al. Maternal abdomen was divided into four quadrants using the umbilicus and linea nigra as landmarks. Single vertical pocket in each quadrant was measured and the AFI was generated by the sum of these four values without umbilical cord or fetal parts. All ultrasound exams were performed by only two experienced examiners. AFI was expressed as median, interquartile range, mean and ranges in each gestational age (GA) interval. Polynomial regressions were performed to obtain the best fit with adjustment by the determination coefficient (R(2)). Mean of AFI ranged from 14.0 ± 4.1 cm (range, 9.7-14.0) at 26w0d to 8.3 ± 4.7 cm (range, 1.9-16.5) at 41w6d, respectively. The best polynomial regression fit curve was a first-degree: AFI = 16.29-0.125*GA (R(2) = 0.01). According the scatterplot, AFI values practically did not vary with advancing GA. Reference values for the AFI measurement between 26w0d and 41w6d of gestation in a low-risk Brazilian population were established.

  11. The importance of centralities in dark network value chains

    NASA Astrophysics Data System (ADS)

    Toth, Noemi; Gulyás, László; Legendi, Richard O.; Duijn, Paul; Sloot, Peter M. A.; Kampis, George

    2013-09-01

    This paper introduces three novel centrality measures based on the nodes' role in the operation of a joint task, i.e., their position in a criminal network value chain. For this, we consider networks where nodes have attributes describing their "capabilities" or "colors", i.e., the possible roles they may play in a value chain. A value chain here is understood as a series of tasks to be performed in a specific order, each requiring a specific capability. The first centrality notion measures how many value chain instances a given node participates in. The other two assess the costs of replacing a node in the value chain in case the given node is no longer available to perform the task. The first of them considers the direct distance (shortest path length) between the node in question and its nearest replacement, while the second evaluates the actual replacement process, assuming that preceding and following nodes in the network should each be able to find and contact the replacement. In this report, we demonstrate the properties of the new centrality measures using a few toy examples and compare them to classic centralities, such as betweenness, closeness and degree centrality. We also apply the new measures to randomly colored empirical networks. We find that the newly introduced centralities differ sufficiently from the classic measures, pointing towards different aspects of the network. Our results also pinpoint the difference between having a replacement node in the network and being able to find one. This is the reason why "introduction distance" often has a noticeable correlation with betweenness. Our studies show that projecting value chains over networks may significantly alter the nodes' perceived importance. These insights might have important implications for the way law enforcement or intelligence agencies look at the effectiveness of dark network disruption strategies over time.

  12. Online physician ratings fail to predict actual performance on measures of quality, value, and peer review.

    PubMed

    Daskivich, Timothy J; Houman, Justin; Fuller, Garth; Black, Jeanne T; Kim, Hyung L; Spiegel, Brennan

    2018-04-01

    Patients use online consumer ratings to identify high-performing physicians, but it is unclear if ratings are valid measures of clinical performance. We sought to determine whether online ratings of specialist physicians from 5 platforms predict quality of care, value of care, and peer-assessed physician performance. We conducted an observational study of 78 physicians representing 8 medical and surgical specialties. We assessed the association of consumer ratings with specialty-specific performance scores (metrics including adherence to Choosing Wisely measures, 30-day readmissions, length of stay, and adjusted cost of care), primary care physician peer-review scores, and administrator peer-review scores. Across ratings platforms, multivariable models showed no significant association between mean consumer ratings and specialty-specific performance scores (β-coefficient range, -0.04, 0.04), primary care physician scores (β-coefficient range, -0.01, 0.3), and administrator scores (β-coefficient range, -0.2, 0.1). There was no association between ratings and score subdomains addressing quality or value-based care. Among physicians in the lowest quartile of specialty-specific performance scores, only 5%-32% had consumer ratings in the lowest quartile across platforms. Ratings were consistent across platforms; a physician's score on one platform significantly predicted his/her score on another in 5 of 10 comparisons. Online ratings of specialist physicians do not predict objective measures of quality of care or peer assessment of clinical performance. Scores are consistent across platforms, suggesting that they jointly measure a latent construct that is unrelated to performance. Online consumer ratings should not be used in isolation to select physicians, given their poor association with clinical performance.

  13. Diagnostic value of serial measurement of C-reactive protein in serum and matrix metalloproteinase-9 in drainage fluid in the detection of infectious complications and anastomotic leakage in patients with colorectal resection.

    PubMed

    Kostić, Zoran; Panišić, Marina; Milev, Boško; Mijušković, Zoran; Slavković, Damjan; Ignjatović, Mile

    2015-10-01

    Postoperative infectious complications are one of the most important problems in surgical treatment of colorectal cancer (CRC), being present in up to 40% of patients. The aim of this paper was to establish the significance of serial measurement of C-reactive protein (CRP) in serum and matrix metalloproteinase-9 (MMP-9) in drainage fluid for the detection of infectious complications and anastomotic leakage (AL) in patients with colorectal resection. CRP and MMP-9 values in serum and drainage fluid, respectively, were measured on the first, third, fifth, and seventh postoperative day (POD) in 150 patients with colorectal resection and primary anastomosis. The values obtained were compared between the patients without complicatons and those with surgical site and remote infections and AL. Surgical site infections (SSIs) were observed in 41 (27.3%), and remote infections in 10 (6.7%) patients. Clinically evident AL was observed in 15 (10/6) patients. In 82% of the patients with SSIs, serum CRP value on POD 5 exceeded 82 mg/L, with 81% specificity. AL was reported in 85% and 92% of the patients on PODs 5 and 7, respectively, with CRP values of 77 mg/L and 90 mg/L, respectively. The specificity was 77% for POD 5 and 88% for POD 7. All the patients with CRP values exceeding 139 mg/L on POD 5 had some of SSIs and/or AL. The mean values of MMP-9 were not statistically different between the group without complications (n = 99) and the group with AL (n = 15). Serial measurement of CRP is recommended for screening of infectious complications of colorectal resection. Patients with CRP values above 139 mg/L on POD 5 cannot be discharged from hospital, and require an intensive search for infectious complications, particularly AL. MMP-9 measurement in drainage fluid is not relevant in the detection of AL in patients with colorectal resection.

  14. An Analysis of the Relationship between the Perceptions of Value-Added Measurement and Teacher Job Satisfaction

    ERIC Educational Resources Information Center

    Viar, Meagan Alexis

    2016-01-01

    Educational leaders are struggling with the issue of academic reform as it pertains to accountability for student achievement. With increasing pressures to improve student achievement, many states have adopted value-added measures to monitor student growth and teacher effectiveness. This study undertook a quantitative approach to examine the…

  15. SU-E-T-271: Direct Measurement of Tenth Value Layer Thicknesses for High Density Concretes with a Clinical Machine

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Tanny, S; Parsai, E; Harrell, D

    2015-06-15

    Purpose: Use of high density concrete for radiation shielding is increasing, trading cost for space savings associated with the reduced tenth value layer (TVL). Precise information on the attenuation properties of high-density concretes is not readily present in the literature. A simple approximation is to scale the TVLs from NCRP 151 according relative increase in density. Here we present measured TVLs for heavy concretes of various densities using a built-in shielding test port. Methods: Concrete densities tested range from 2.35 g cc{sup −1} (147 pcf) to 5.6 g cc{sup −1} (350 pcf). Measurements were taken using 6MV, 6FFF, and 10FFFmore » on a Varian Truebeam linear accelerator. Field sizes of 4x4, 9x9 and 30x30 cm{sup 2} were measured. A PTW 31013 Farmer chamber with a buildup cap was positioned 5.5 m from isocenter along the beam CAX. Concrete thicknesses were incremented in 5 cm intervals. Comparison TVLs were determined by scaling the NCRP 151 TVLs by the density ratio between the sample and standard density. Results: The trend from the first to equilibrium TVL was an increase in thickness, compared with MC modeling, which predicted a decrease. Measured TVLs for 6 MV were reduced by as much as 8.9 cm for TVL{sub 1} and 3.4 cm for TVL{sub E} compared to values scaled from NCRP 151. There was 1–3 mm difference in TVL between measurements done at 4x4 versus 30x30 cm{sup 2}. TVL{sub 1} for 6FFF was 1.1 cm smaller than TVL{sub 1} for 6MV, but TVL{sub E} was consistent to within 4 mm. TVL{sub 1} and TVL{sub E} for 10FFF were reduced by 8.8 and 3.7 cm from scaled NCRP values, respectively. Conclusions: We have measured the TVL thicknesses for various concretes. Simple density scaling of the values in NCRP 151 is a conservatively safe approximation, but actual TVLs may be reduced enough to eliminate some of the expense of installation. Daniel Harrell and Jim Noller are employees of Shielding Construction Solutions, Inc, the shielding construction company that

  16. Changes in intraocular pressure values measured with noncontact tonometer (NCT), ocular response analyzer (ORA) and corvis scheimpflug technology tonometer (CST) in the early phase after small incision lenticule extraction (SMILE).

    PubMed

    Shen, Yang; Su, Xiangjian; Liu, Xiu; Miao, Huamao; Fang, Xuejun; Zhou, Xingtao

    2016-11-18

    Corneal biomechanical properties are always compromised after corneal refractive surgeries thus leading to underestimated intraocular pressure (IOP) that complicates the management of IOP. We investigated the changes in postoperative baseline of IOP values measured with noncontact tonometer (NCT), ocular response analyzer (ORA) and corvis scheimpflug technology (CST) in the early phase after small incision lenticule extraction (SMILE). Twenty-two eyes (-6.76 ± 1.39D) of 22 moderate and high myopes, (28.36 ± 7.14 years, 12 male and 10 female) were involved in this prospective study. IOP values were measured using a non-contact tomometer (NCT-IOP), an ocular response analyzer (corneal-compensated IOP, IOPcc and Goldmann-correlated IOP, IOPg) and a Corvis scheimpflug technology tonometer (CST-IOP) preoperatively, at 20 min and 24 h, postoperatively. Repeated measures analysis of variance (RM-ANOVA), Pearson's correlation analysis and multiple linear regression models (stepwise) were performed. Cut-off P values were 0.05. Except for IOPcc, NCT-IOP, IOPg, and CST-IOP values significantly decreased after SMILE procedure (All P values <0.05). ΔCCT, as well as ΔMRSE and ΔKm, did not significantly correlated with ΔNCT-IOP, ΔIOPcc, ΔIOPg or ΔCST-IOP, (all P values >0.05). Multiple linear regression models (stepwise) showed that the practical post-operative IOP value was the main predictor of the theoretical post-operative NCT-IOP, IOPcc and IOPg values (all P values <0.001). The postoperative applanation time 1 (AT1) value (B = 8.079, t = 4.866, P < 0.001), preoperative central corneal thickness (CCT) value (B = 0.035, t = 2.732, P = 0.014) and postoperative peak distance (PD) value (B = 0.515, t = 2.176, P = 0.043) were the main predictors of the theoretical post-operative CST-IOP value. IOP values are underestimated when assessed after SMILE by using NCT-IOP, IOPg and CST-IOP. The practical postoperative IOPcc value

  17. Provider perceptions of the value of same-day, electronic patient-reported measures for use in clinical HIV care

    PubMed Central

    Fredericksen, RJ; Tufano, J; Ralston, J; McReynolds, J; Stewart, M; Lober, WB; Mayer, K; Mathews, WC; Mugavero, M; Crane, PK; Crane, HM

    2016-01-01

    Strong evidence suggests that patient-reported outcomes (PROs) aid in managing chronic conditions, reduce omissions in care, and improve patient-provider communication. However, provider acceptability of PROs and their use in clinical HIV care is not well known. We interviewed providers (n=27) from four geographically diverse HIV and community care clinics in the U.S. that have integrated PROs into routine HIV care, querying perceived value, challenges, and use of PRO data. Perceived benefits included the ability of PROs to identify less-observable behaviors and conditions, particularly suicidal ideation, depression, and substance use; usefulness in agenda-setting prior to a visit; and reduction of social desirability bias in patient-provider communication. Challenges included initial flow integration issues and ease of interpretation of PRO feedback. Providers value same-day, electronic patient-reported measures for use in clinical HIV care with the condition that PROs are 1) tailored to be the most clinically relevant to their population; 2) well-integrated into clinic flow; 3) easy to interpret, highlighting chief patient concerns and changes over time. PMID:27237187

  18. Experimental scheme for qubit and qutrit symmetric informationally complete positive operator-valued measurements using multiport devices

    NASA Astrophysics Data System (ADS)

    Tabia, Gelo Noel M.

    2012-12-01

    It is crucial for various quantum information processing tasks that the state of a quantum system can be determined reliably and efficiently from general quantum measurements. One important class of measurements for this purpose is symmetric informationally complete positive operator-valued measurements (SIC-POVMs). SIC-POVMs have the advantage of providing an unbiased estimator for the quantum state with the minimal number of outcomes needed for full tomography. By virtue of Naimark's dilation theorem, any POVM can always be realized with a suitable coupling between the system and an auxiliary system and by performing a projective measurement on the joint system. In practice, finding the appropriate coupling is rather nontrivial. Here we propose an experimental design for directly implementing SIC-POVMs using multiport devices and path-encoded qubits and qutrits, the utility of which has recently been demonstrated by several experimental groups around the world. Furthermore, we describe how these multiports can be attained in practice with an integrated photonic system composed of nested linear optical elements.

  19. An Intercomparison of Lidar Ozone and Temperature Measurements From the SOLVE Mission With Predicted Model Values

    NASA Technical Reports Server (NTRS)

    Burris, John; McGee, Thomas J.; Hoegy, Walt; Lait, Leslie; Sumnicht, Grant; Twigg, Larry; Heaps, William

    2000-01-01

    Temperature profiles acquired by Goddard Space Flight Center's AROTEL lidar during the SOLVE mission onboard NASA's DC-8 are compared with predicted values from several atmospheric models (DAO, NCEP and UKMO). The variability in the differences between measured and calculated temperature fields was approximately 5 K. Retrieved temperatures within the polar vortex showed large regions that were significantly colder than predicted by the atmospheric models.

  20. Value-Based Reimbursement: Impact of Curtailing Physician Autonomy in Medical Decision Making.

    PubMed

    Gupta, Dipti; Karst, Ingolf; Mendelson, Ellen B

    2016-02-01

    In this article, we define value in the context of reimbursement and explore the effect of shifting reimbursement paradigms on the decision-making autonomy of a women's imaging radiologist. The current metrics used for value-based reimbursement such as report turnaround time are surrogate measures that do not measure value directly. The true measure of a physician's value in medicine is accomplishment of better health outcomes, which, in breast imaging, are best achieved with a physician-patient relationship. Complying with evidence-based medicine, which includes data-driven best clinical practices, a physician's clinical expertise, and the patient's values, will improve our science and preserve the art of medicine.

  1. Average snowcover density values in Eastern Alps mountain

    NASA Astrophysics Data System (ADS)

    Valt, M.; Moro, D.

    2009-04-01

    The Italian Avalanche Warning Services monitor the snow cover characteristics through networks evenly distributed all over the alpine chain. Measurements of snow stratigraphy and density are very frequently performed with sampling rates of 1 -2 times per week. Snow cover density values are used to compute the dimensions of the building roofs as well as to design avalanche barriers. Based on the measured snow densities the Electricity Board can predict the amount of water resources deriving from snow melt in high relieves drainage basins. In this work it was possible to compute characteristic density values of the snow cover in the Eastern Alps using the information contained in the database from the ARPA (Agenzia Regionale Protezione Ambiente)-Centro Valanghe di Arabba, and Ufficio Valanghe- Udine. Among the other things, this database includes 15 years of stratigraphic measurements. More than 6,000 snow stratigraphic logs were analysed, in order to derive typical values as for geographical area, altitude, exposure, snow cover thickness and season. Computed values were compared to those established by the current Italian laws. Eventually, experts identified and evaluated the correlations between the seasonal variations of the average snow density and the variations related to the snowfall rate in the period 1994-2008 in the Eastern Alps mountain range

  2. Family Relational Values in the Parent-Adolescent Relationship

    ERIC Educational Resources Information Center

    Edgar-Smith, Susan E.; Wozniak, Robert H.

    2010-01-01

    This study measured the relational family values system of upper-middle-class mothers, fathers, and adolescents in the United States. Results revealed that participants shared common family values that mainly reflected the importance of individualism, equality in family relationships, family member interdependence, and parental guidance. Parent…

  3. The effects of measurement site and ambient temperature on body temperature values in healthy older adults: a cross-sectional comparative study.

    PubMed

    Lu, Shu-Hua; Dai, Yu-Tzu; Yen, Chung-Jen

    2009-11-01

    Accurate baseline body temperature measurement is essential for assessment. Tympanic membrane temperature (TMT) measurement is popular, but there is no consensus on whether it is as accurate as oral temperature (OT) for use with the elderly at varying ambient temperature levels. To test agreement between TMT and OT measurement of body temperature among an elderly population; and to explore whether agreement between the two sites depends on ambient temperature. A cross-sectional comparison study. Two samples of older community-dwelling adults were recruited from 17 community senior citizen centers in Taipei, Taiwan in winter (n=262) and summer (n=257) of 2007. TMT and OT were simultaneously measured by electronic infrared ear thermometer and electronic digital thermometer. Ambient temperatures measured by digital thermo-hygrometer of the data collection setting were recorded when body temperature was taken. In winter mean TMT was 36.64 degrees C (S.D. 0.37), and mean OT was 36.74 degrees C (S.D. 0.18). In summer, the mean TMT was 37.05 degrees C (S.D. 0.30) and mean OT was 36.85 degrees C (S.D. 0.22). The relationship between TMT and OT were r=0.42 (p<0.001) in winter and r=0.57 (p<0.001) in summer. The values of OT were used as standard to assess the accuracy of the measurement. The bias between TMT and OT was -0.10 degrees C (S.D. 0.34) and 95% limits of agreement were 0.57 and -0.77 degrees C in winter; and bias was 0.20 degrees C (S.D. 0.25) and 95% limits of agreement were 0.69 and -0.29 degrees C in summer. The findings of this study demonstrate that the TMT has high variability that may under or over estimate body temperatures. There is a lack of agreement in body temperatures values between TMT and OT in community-dwelling elderly in both winter and summer. OT was more stable than TMT regardless of ambient temperature influences. Therefore, the oral cavity is preferable to the TM site for temperature measurement in alert elderly. The limitation of this study

  4. Appraisal of application possibilities of smoothed splines to designation of the average values of terrain curvatures measured after the termination of hard coal exploitation conducted at medium depth

    NASA Astrophysics Data System (ADS)

    Orwat, J.

    2018-01-01

    In paper were presented results of average values calculations of terrain curvatures measured after the termination of subsequent exploitation stages in the 338/2 coal bed located at medium depth. The curvatures were measured on the neighbouring segments of measuring line No. 1 established perpendicularly to the runways of four longwalls No. 001, 002, 005 and 007. The average courses of measured curvatures were designated based on average courses of measured inclinations. In turn, the average values of observed inclinations were calculated on the basis of measured subsidence average values. In turn, they were designated on the way of average-square approximation, which was done by the use of smoothed splines, in reference to the theoretical courses determined by the S. Knothe’s and J. Bialek’s formulas. Here were used standard parameters values of a roof rocks subsidence a, an exploitation rim Aobr and an angle of the main influences range β. The values of standard deviations between the average and measured curvatures σC and the variability coefficients of random scattering of curvatures MC were calculated. They were compared with values appearing in the literature and based on this, a possibility appraisal of the use of smooth splines to designation of average course of observed curvatures of mining area was conducted.

  5. Values in First-Episode Schizophrenia.

    PubMed

    Agid, Ofer; Mcdonald, Krysta; Fervaha, Gagan; Littrell, Romie; Thoma, Jessica; Zipursky, Robert B; Foussias, George; Remington, Gary

    2015-11-01

    Functional impairment continues to represent a major challenge in schizophrenia. Surprisingly, patients with schizophrenia report a level of happiness comparable with control subjects, even in the face of the prominent functional deficits, a finding at odds with evidence indicating a positive relation between happiness and level of functioning. In attempting to reconcile these findings, we chose to examine the issue of values, defined as affectively infused criteria or motivational goals used to select and justify actions, people, and the self, as values are related to both happiness and functioning. Fifty-six first-episode patients in remission and 56 healthy control subjects completed happiness and values measures. Statistical analyses included correlations, analysis of variance, structural equation modelling, and smallest space analysis. Results indicated that patients with schizophrenia placed significantly greater priority on the value dimensions of Tradition (P = 0.02) and Power (P = 0.03), and significantly less priority on Self-direction (P = 0.007) and Stimulation, (P = 0.008). Essentially, people with schizophrenia place more emphasis on the customs and ideas that traditional culture or religion provide in conjunction with a decreased interest in change, which is at odds with the expectations of early adulthood. This value difference could be related to functional deficits. To this point, we have assumed that people hold to the same values that guided them before the illness' onset, but this may not be the case. Our study indicates that values differ in people with schizophrenia, compared with control subjects, even early in the illness and in the face of symptomatic remission.

  6. Measuring the Value Added of Management: A Knowledge Value Added Approach

    DTIC Science & Technology

    2006-12-31

    Dark Matter ” ................................................................3 Difficult-to-track Dark Matter Outputs .................................................5 Computing Metaphor..........................................................................6 Dark Matter Correlates with Market Performance ..............................8 Outputs of Dark Matter .......................................................................9 Operationalizing: The Measurement of Dark

  7. Measuring Virtual Simulations Value in Training Exercises - USMC Use Case

    DTIC Science & Technology

    2015-12-04

    and cost avoidance and Capt Jonathan Richardson, PM TRASYS, who was the primary author for the After-Action Documentation and Analysis Report ...REFERENCES Cermak J. & McGurk M. (2010, July). Putting a Value On Training. McKinsey Quarterly. Retrieved June 10, 2015 from http://www.mckinsey.com...www.hqmc.marines.mil/Portals/142/Docs/2015CPG_Color.pdf Gordon, S. & Cooley, T. (2013) Phase One Final Report : Cost Avoidance Study of USMC Simulation

  8. A comparison of airborne wake vortex detection measurements with values predicted from potential theory

    NASA Technical Reports Server (NTRS)

    Stewart, Eric C.

    1991-01-01

    An analysis of flight measurements made near a wake vortex was conducted to explore the feasibility of providing a pilot with useful wake avoidance information. The measurements were made with relatively low cost flow and motion sensors on a light airplane flying near the wake vortex of a turboprop airplane weighing approximately 90000 lbs. Algorithms were developed which removed the response of the airplane to control inputs from the total airplane response and produced parameters which were due solely to the flow field of the vortex. These parameters were compared with values predicted by potential theory. The results indicated that the presence of the vortex could be detected by a combination of parameters derived from the simple sensors. However, the location and strength of the vortex cannot be determined without additional and more accurate sensors.

  9. Weak values of spin and momentum in atomic systems.

    NASA Astrophysics Data System (ADS)

    Flack, Robert; Hiley, Basil; Barker, Peter; Monachello, Vincenzo; Morley, Joel

    2017-04-01

    Weak values have a long history and were first considered by Landau and London in connection with superfluids. Hirschfelder called them sub-observables and Dirac anticipatied them when discussing non-commutative geometry in quantum mechanics. The idea of a weak value has returned to prominence due to Aharonov, Albert and Vaidman showing how they can be measured. They are not eigenvalues of the system and can not be measured by a collapse of the wave function with the traditional Von Neumann (strong) measurement which is a single stage process. In contrast the weak measurement process has three stages; preselection, weak stage and finally a post selection. Although weak values have been observed using photons and neutrons, we are building two experiments to observe weak values of spin and momentum in atomic systems. For spin we are following the method outlined by Duck et al which is a variant on the original Stern-Gerlach experiment using a metastable, 23S1 , form of helium. For momentum we are using a method similar to that used by Kocsis with excited argon atoms in the 3P2 state, passing through a 2-slit interferometer. The design, simulation and re John Fetzer Memorial Trust.

  10. Ocular blood flow values measured by laser speckle flowgraphy correlate with the postmenstrual age of normal neonates.

    PubMed

    Matsumoto, Tadashi; Itokawa, Takashi; Shiba, Tomoaki; Katayama, Yuuji; Arimura, Tetsushi; Hine, Kotaro; Mizukaki, Norio; Yoda, Hitoshi; Hori, Yuichi

    2016-08-01

    To evaluate the relationships between optic nerve head (ONH) blood flow by laser speckle flowgraphy (LSFG), and postmenstrual age and body weight in normal neonates. During their normal sleep, we studied 24 infants (postmenstrual age, 248-295 days) whose ocular blood flow could be measured three consecutive times. While the subjects slept in the supine position, three mean blur rate (MBR) values of the ONH were obtained: the MBR-A (mean of all values), MBR-V (vessel mean) and MBR-T (tissue mean) in the ONH. With regard to eye diseases, no retinopathy of prematurity (ROP) was observed, and no severe systemic diseases requiring treatment were noted in the subjects. Pearson's correlation coefficients were used to determine the relationship between the MBR-A, -V, -T and postmenstrual age (days) and body weight (g). Postmenstrual age was significantly correlated with MBR-A (r = 0.64, p = 0.0007), MBR-V (r = 0.62, p = 0.0012) and MBR-T (r = 0.62, p = 0.0012). However, the body weight was not correlated with the MBR (MBR-A: r = 0.37, p = 0.07, MBR-V: r = 0.31, p = 0.14, MBR-T: r = 0.38, p = 0.06). Our results clarified that the values of ocular blood flow measured by LSFG correlate with the postmenstrual age of normal neonates.

  11. Inter- and intratester reliability values of ultrasound imaging measurements of diaphragm movement in the thoracic and thoracolumbar curves in adolescent idiopathic scoliosis.

    PubMed

    Noh, Dong Koog; Koh, Jae-Hyun; You, Joshua Sung-H

    2016-01-01

    The purpose of this study was to determine intertester and intratester reliability of ultrasound measurements of bilateral diaphragm excursions in the thoracic and thoracolumbar spinal curves of 31 females with adolescent idiopathic scoliosis (AIS) (mean age = 14.1 ± 1.8 years). Subjects were tested during tidal breathing using real-time ultrasound imaging with a 3.5 MHz curvilinear transducer. There were no significant differences in intratester and intertester reliability values in bilateral diaphragmatic excursions measured at the thoracolumbar spinal curve, whereas significant differences were observed in measurements taken at the thoracic spinal curve (p < 0.05). Overall, the intertester and intratester reliabilities of the thoracic and thoracolumbar curves in AIS ranged from 0.764 to 0.998. These findings suggest that ultrasound imaging is highly reliable between and within testers and is useful to precisely discriminate pathological diaphragm movement in idiopathic thoracic scoliosis and idiopathic thoracolumbar scoliosis.

  12. Improving Value for Patients with Eczema.

    PubMed

    Block, Julie

    2018-04-01

    Chronic diseases now represent a cost majority in the United States health care system. Contributing factors to rising costs include expensive novel and emerging therapies, under-treatment of disease, under-management of comorbidities, and patient dissatisfaction with care results. Critical to identifying replicable improvement methods is a reliable model to measure value. If we understand value within healthcare consumerism to be equal to a patient's health outcome improvement over costs associated with care (Value=Outcomes/Costs), we can use this equation to measure the improvement of value. Research and literature show that patient activation-the skills and confidence that equip patients to become actively engaged in their health care-impact health outcomes, costs, and patient experience. Reaching patient activation through engagement methods including shared decision-making (SDM) lead to improved value of care received. The National Eczema Association (NEA) Shared Decision-Making Resource Center can be a transformative strategy to measure and evaluate value of health care interventions for eczema patients to advance a value-driven health care system in the United States. Through this Resource Center, NEA will measure patient value through their own perceptions using validated PRO instruments and other patient-generated health data. Assessment of this data will reveal findings that can assist researchers in evaluating the impact this care framework on patient-perceived value across other chronic diseases. Copyright © 2018 International Society for Pharmacoeconomics and Outcomes Research (ISPOR). Published by Elsevier Inc. All rights reserved.

  13. Does Value-Added Work Better in Elementary than in Secondary Grades? What We Know Series: Value-Added Methods Applications. Knowledge Brief 7

    ERIC Educational Resources Information Center

    Harris, Douglas N.; Anderson, Andrew

    2013-01-01

    There is a growing body of research on the validity and reliability of value-added measures, but most of this research has focused on elementary grades. Driven by several federal initiatives such as Race to the Top, Teacher Incentive Fund, and ESEA waivers, however, many states have incorporated value-added measures into the evaluations not only…

  14. The Value Question in Metaphysics

    PubMed Central

    Kahane, Guy

    2012-01-01

    Much seems to be at stake in metaphysical questions about, for example, God, free will or morality. One thing that could be at stake is the value of the universe we inhabit—how good or bad it is. We can think of competing philosophical positions as describing possibilities, ways the world might turn out to be, and to which value can be assigned. When, for example, people hope that God exists, or fear that we do not possess free will, they express attitudes towards these possibilities, attitudes that presuppose answers to questions about their comparative value. My aim in this paper is to distinguish these evaluative questions from related questions with which they can be confused, to identify structural constraints on their proper pursuit, and to address objections to their very coherence. Answers to such evaluative questions offer one measure of the importance of philosophical disputes. PMID:23024399

  15. The Value Question in Metaphysics.

    PubMed

    Kahane, Guy

    2012-07-01

    Much seems to be at stake in metaphysical questions about, for example, God, free will or morality. One thing that could be at stake is the value of the universe we inhabit-how good or bad it is. We can think of competing philosophical positions as describing possibilities, ways the world might turn out to be, and to which value can be assigned. When, for example, people hope that God exists, or fear that we do not possess free will, they express attitudes towards these possibilities, attitudes that presuppose answers to questions about their comparative value. My aim in this paper is to distinguish these evaluative questions from related questions with which they can be confused, to identify structural constraints on their proper pursuit, and to address objections to their very coherence. Answers to such evaluative questions offer one measure of the importance of philosophical disputes.

  16. Combining Time-Driven Activity-Based Costing with Clinical Outcome in Cost-Effectiveness Analysis to Measure Value in Treatment of Depression.

    PubMed

    El Alaoui, Samir; Lindefors, Nils

    2016-01-01

    A major challenge of mental health care is to provide safe and effective treatment with limited resources. The main purpose of this study was to examine a value-based approach in clinical psychiatry when evaluating a process improvement initiative. This was accomplished by using the relatively new time driven activity based costing (TDABC) method within the more widely adopted cost-effectiveness analysis framework for economic evaluation of healthcare technologies. The objective was to evaluate the cost-effectiveness of allowing psychologists to perform post-treatment assessment previously performed by psychiatrists at an outpatient clinic treating depression using internet-based cognitive-behavioral therapy (ICBT). Data was collected from 568 adult patients treated with ICBT for depression during 2013-2014. The TDABC methodology was used to estimate total healthcare costs, including development of process maps for the complete cycle of care and estimation of resource use and minute costs of staff, hospital space and materials based on their relative proportions used. Clinical outcomes were measured using the Patient Health Questionnaire depression scale (PHQ-9) before and after treatment and at 6-month follow-up. Cost-effectiveness analyses (CEA) was performed and the results presented as incremental net benefits (INB), cost-effectiveness acceptability curves (CEACs) and confidence ellipses to demonstrate uncertainty around the value of the organizational intervention. Taking into account the complete healthcare process (from referral to follow-up assessment), treatment costs decreased from $709 (SD = $130) per patient in 2013 to $659 (SD = $134) in 2014 while treatment effectiveness was maintained; 27% had achieved full remission from depression after treatment (PHQ-9 < 5) during both 2013 and 2014 and an additional 35% and 33% had achieved partial remission in 2013 and 2014, respectively. At follow-up, 42% were in full remission after treatment during both 2013

  17. Combining Time-Driven Activity-Based Costing with Clinical Outcome in Cost-Effectiveness Analysis to Measure Value in Treatment of Depression

    PubMed Central

    Lindefors, Nils

    2016-01-01

    Background A major challenge of mental health care is to provide safe and effective treatment with limited resources. The main purpose of this study was to examine a value-based approach in clinical psychiatry when evaluating a process improvement initiative. This was accomplished by using the relatively new time driven activity based costing (TDABC) method within the more widely adopted cost-effectiveness analysis framework for economic evaluation of healthcare technologies. The objective was to evaluate the cost-effectiveness of allowing psychologists to perform post-treatment assessment previously performed by psychiatrists at an outpatient clinic treating depression using internet-based cognitive-behavioral therapy (ICBT). Methods Data was collected from 568 adult patients treated with ICBT for depression during 2013–2014. The TDABC methodology was used to estimate total healthcare costs, including development of process maps for the complete cycle of care and estimation of resource use and minute costs of staff, hospital space and materials based on their relative proportions used. Clinical outcomes were measured using the Patient Health Questionnaire depression scale (PHQ-9) before and after treatment and at 6-month follow-up. Cost-effectiveness analyses (CEA) was performed and the results presented as incremental net benefits (INB), cost-effectiveness acceptability curves (CEACs) and confidence ellipses to demonstrate uncertainty around the value of the organizational intervention. Outcomes Taking into account the complete healthcare process (from referral to follow-up assessment), treatment costs decreased from $709 (SD = $130) per patient in 2013 to $659 (SD = $134) in 2014 while treatment effectiveness was maintained; 27% had achieved full remission from depression after treatment (PHQ-9 < 5) during both 2013 and 2014 and an additional 35% and 33% had achieved partial remission in 2013 and 2014, respectively. At follow-up, 42% were in full remission

  18. Further insight into the incremental value of new markers: the interpretation of performance measures and the importance of clinical context.

    PubMed

    Kerr, Kathleen F; Bansal, Aasthaa; Pepe, Margaret S

    2012-09-15

    In this issue of the Journal, Pencina and et al. (Am J Epidemiol. 2012;176(6):492-494) examine the operating characteristics of measures of incremental value. Their goal is to provide benchmarks for the measures that can help identify the most promising markers among multiple candidates. They consider a setting in which new predictors are conditionally independent of established predictors. In the present article, the authors consider more general settings. Their results indicate that some of the conclusions made by Pencina et al. are limited to the specific scenarios the authors considered. For example, Pencina et al. observed that continuous net reclassification improvement was invariant to the strength of the baseline model, but the authors of the present study show this invariance does not hold generally. Further, they disagree with the suggestion that such invariance would be desirable for a measure of incremental value. They also do not see evidence to support the claim that the measures provide complementary information. In addition, they show that correlation with baseline predictors can lead to much bigger gains in performance than the conditional independence scenario studied by Pencina et al. Finally, the authors note that the motivation of providing benchmarks actually reinforces previous observations that the problem with these measures is they do not have useful clinical interpretations. If they did, researchers could use the measures directly and benchmarks would not be needed.

  19. Validation of the Consumer Values versus Perceived Product Attributes Model Measuring the Purchase of Athletic Team Merchandise

    ERIC Educational Resources Information Center

    Lee, Donghun; Byon, Kevin K.; Schoenstedt, Linda; Johns, Gary; Bussell, Leigh Ann; Choi, Hwansuk

    2012-01-01

    Various consumer values and perceived product attributes trigger consumptive behaviors of athletic team merchandise (Lee, Trail, Kwon, & Anderson, 2011). Likewise, using a principal component analysis technique on a student sample, a measurement scale was proposed that consisted of nine factors affecting the purchase of athletic team…

  20. Critical values in hematology of 862 institutions in China.

    PubMed

    Ye, Y Y; Zhao, H J; Fei, Y; Wang, W; He, F L; Zhong, K; Yuan, S; Wang, Z G

    2017-10-01

    A national survey on critical values in hematology of China laboratories was conducted to determine the current practice and assess the quality indicators so as to obtain a quality improvement. Laboratories participating were asked to submit the general information, the practice of critical value reporting, and the status of timeliness of critical value reporting. A total of 862 laboratories submitted the results. The majority of participants have included white blood cell count, blood platelet count, hemoglobin, prothrombin time, and activated partial thromboplastin time in their critical value lists. Many sources are used for establishing a critical value policy, and some of the laboratories consult with clinicians. The unreported critical value rate, late critical value reporting rate, and clinically unacknowledged rate in China are relatively low, and the median of critical value reporting time is 8-9 minutes. There exists a wide variety for critical value reporting in hematology in China. Laboratories should establish a policy of critical value reporting suited for their own situations and consult with clinicians to set critical value lists. Critical values are generally reported in a timely manner in China, but some measures should be taken to further improve the timeliness of critical value reporting. © 2017 John Wiley & Sons Ltd.

  1. Interval-Valued Rank in Finite Ordered Sets

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Joslyn, Cliff; Pogel, Alex; Purvine, Emilie

    We consider the concept of rank as a measure of the vertical levels and positions of elements of partially ordered sets (posets). We are motivated by the need for algorithmic measures on large, real-world hierarchically-structured data objects like the semantic hierarchies of ontolog- ical databases. These rarely satisfy the strong property of gradedness, which is required for traditional rank functions to exist. Representing such semantic hierarchies as finite, bounded posets, we recognize the duality of ordered structures to motivate rank functions which respect verticality both from the bottom and from the top. Our rank functions are thus interval-valued, and alwaysmore » exist, even for non-graded posets, providing order homomorphisms to an interval order on the interval-valued ranks. The concept of rank width arises naturally, allowing us to identify the poset region with point-valued width as its longest graded portion (which we call the “spindle”). A standard interval rank function is naturally motivated both in terms of its extremality and on pragmatic grounds. Its properties are examined, including the relation- ship to traditional grading and rank functions, and methods to assess comparisons of standard interval-valued ranks.« less

  2. U.S. Dental School Deans' Views on the Value of Patient-Reported Outcome Measures in Dentistry.

    PubMed

    Rosen, Evan B; Donoff, R Bruce; Riedy, Christine A

    2016-06-01

    There has historically been limited development and utilization of patient-reported outcome measures (PROMs) in clinical dentistry. However, in recent years PROMs have been recognized by other health care fields as valuable in the comprehensive assessment of patient outcomes. The aim of this study was to survey deans of U.S. dental schools to better understand their vision for the role of PROMs in the field of dentistry. A 13-question online survey was emailed to the deans of the 64 accredited U.S. dental schools at the time to gather their opinions about the value of patient-reported outcomes in dentistry. The survey consisted of questions in 12 domains such as treatment planning, perceived success/complications of surgery, identification/management of dental pain, psychological and oral function, and insurance payment/reimbursement. Of the 64 deans, 33 responses were received (51.5% response rate), but three surveys were excluded due to incomplete answers, resulting in a final response rate of 46.8%. All respondents reported there was value in utilization of PROMs for understanding a patient's satisfaction of a procedure, a patient's perceived success of dental surgery, identifying dental pain, and managing dental pain. However, there was disagreement among the respondents about utilization of PROMs for the purpose of determining insurance payment and/or reimbursement. Additional steps should be taken to develop clinically appropriate PROMs for dentistry and to determine the appropriate situations in which to use dental PROMs. This study suggests that PROMs should be incorporated into dental school curricula as they will likely play a role in future comprehensive treatment assessment.

  3. [Clinical value of serum presepsin (SCD14-ST) concentration measurement in patients with pesticide poisoning].

    PubMed

    Gao, X; Zhu, B Y; Wang, W Z; He, J Q; Han, D L; Liu, Y J; Meng, H; Xiao, Q M; Liu, X T; Han, Y Y

    2016-05-20

    To investigate the value of serum presepsin concentration measurement in the clinical diagnosis and treatment of patients with pesticide poisoning patients. A total of 160 patients with pesticide poisoning were enrolled as study subjects and divided into moderate organophosphate pesticide poisoning group (40 patients) , severe organophosphate pesticide poisoning group (40 patients) , abamectin pesticide poisoning group (40 patients) , and paraquat poisoning group (40 patients). A total of 20 healthy volunteers were enrolled as the control group. All the patients with poisoning received conventional treatment of pesticide poisoning immediately after admission, and serum presepsin concentration was measured on days 1 (within 24 hours after poisoning) , 3, and 7 of admission, and biochemical and radiological parameters related to the patient's condition were also examined. The patients with a Presepsin concentration of >800 pg/ml on day 1 of admission were randomly divided into conventional treatment group and ulinastatin treatment group, and the treatment outcome was compared between the two groups. Compared with the healthy control group, the groups with pesticide poisoning showed significant increases in serum Presepsin concentrations, with the highest degree of increase on day 1 (P <0.05). The serum Presepsin concentration was positively correlated with alanine aminotransferase, aspartate aminotransferase, creatine kinase, creatine kinase MB, lactate dehydrogenase, serum creatinine, blood urea nitrogen, interleukin-18, and white blood cell count, but negatively correlated with cholinesterase. In the conventional treatment group and ulinastatin treatment group, the overall response rate was 68% and 78.8%, respectively, with a significant difference between the two groups (P<0.05). In 40 patients with paraquat poisoning, 32 experienced an increase in serum presepsin concentration, and among these 32 patients, 27 (83%) experienced exudation on lung CT. Serum

  4. Measuring the Value of Statistical Life: Estimating Compensating Wage Differentials among Workers in India

    ERIC Educational Resources Information Center

    Madheswaran, S.

    2007-01-01

    Policy makers confronted with the need to introduce health and safety regulations often wonder how to value the benefits of these regulations. One way that a monetary value could be placed on reductions in health risks, including risk of death, is through understanding how people are compensated for the different risks they take. While there is an…

  5. A systematic review of the angular values obtained by computerized photogrammetry in sagittal plane: a proposal for reference values.

    PubMed

    Krawczky, Bruna; Pacheco, Antonio G; Mainenti, Míriam R M

    2014-05-01

    Reference values for postural alignment in the coronal plane, as measured by computerized photogrammetry, have been established but not for the sagittal plane. The objective of this study is to propose reference values for angular measurements used for postural analysis in the sagittal plane for healthy adults. Electronic databases (PubMed, BVS, Cochrane, Scielo, and Science Direct) were searched using the following key words: evaluation, posture, photogrammetry, and software. Articles published between 2006 and 2012 that used the PAS/SAPO (postural assessment software) were selected. Another inclusion criterion was the presentation of, at least, one of the following measurements: head horizontal alignment, pelvic horizontal alignment, hip angle, vertical alignment of the body, thoracic kyphosis, and lumbar lordosis. Angle samples of the selected articles were grouped 2 by 2 in relation to an overall average, which made possible total average, variance, and SD calculations. Six articles were included, and the following average angular values were found: 51.42° ± 4.87° (head horizontal alignment), -12.26° ± 5.81° (pelvic horizontal alignment), -6.40° ± 3.86° (hip angle), and 1.73° ± 0.94° (vertical alignment of the body). None of the articles contained the measurements for thoracic kyphosis and lumbar lordosis. The reference values can be adopted as reference for postural assessment in future researches if the same anatomical points are considered. Copyright © 2014 National University of Health Sciences. Published by Mosby, Inc. All rights reserved.

  6. A tool to measure nurse efficiency and value.

    PubMed

    Landry, M T; Landry, H T; Hebert, W

    2001-07-01

    Home care nurses who have multiple roles can increase their value by validating their contributions and work efficiency. This article presents a method for tracking nurse efficiency for those who are paid on an hourly basis, and provides a mechanism to document their contributions to the home care agency.

  7. Measurements in Flight of the Pressure Distribution on the Right Wing of a Pursuit-Type Airplane at Several Values of Mach Number

    NASA Technical Reports Server (NTRS)

    Clousing, Lawrence A; Turner, William N; Rolls, L Stewart

    1946-01-01

    Pressure-distribution measurements were made on the right wing of a pursuit-type airplane at values of Mach number up to 0.80. The results showed that a considerable portion of the lift was carried by components of the airplane other than the wings, and that the proportion of lift carried by the wings may vary considerably with Mach number, thus changing the bending moment at the wing root whether or not there is a shift in the lateral position of the center of pressure. It was also shown that the center of pressure does not necessarily move outward at high Mach numbers, even though the wing-thickness ratio decreases toward the wing tip. The wing pitching-moment coefficient increased sharply in a negative direction at a Mach lift-curve slope increased with Mach number up to values of above the critical value. Pressures inside the wing were small and negative.

  8. Modeling the Effect of Grain Size Mixing on Thermal Inertia Values Derived from Diurnal and Seasonal THEMIS Measurements

    NASA Astrophysics Data System (ADS)

    McCarty, C.; Moersch, J.

    2017-12-01

    Sedimentary processes have slowed over Mars' geologic history. Analysis of the surface today can provide insight into the processes that may have affected it over its history. Sub-resolved checkerboard mixtures of materials with different thermal inertias (and therefore different grain sizes) can lead to differences in thermal inertia values inferred from night and day radiance observations. Information about the grain size distribution of a surface can help determine the degree of sorting it has experienced or it's geologic maturity. Standard methods for deriving thermal inertia from measurements made with THEMIS can give values for the same location that vary by as much as 20% between scenes. Such methods make the assumption that each THEMIS pixel contains material that has uniform thermophysical properties. Here we propose that if a mixture of small and large particles is present within a pixel, the inferred thermal inertia will be strongly dominated by whichever particle is warmer at the time of the measurement because the power radiated by a surface is proportional (by the Stefan-Boltzmann law) to the fourth power of its temperature. This effect will result in a change in thermal inertia values inferred from measurements taken at different times of day and night. Therefore, we expect to see correlation between the magnitude of diurnal variations in inferred thermal inertia values and the degree of grain size mixing for a given pixel location. Preliminary work has shown that the magnitude of such diurnal variation in inferred thermal inertias is sufficient to detect geologically useful differences in grain size distributions. We hypothesize that at least some of the 20% variability in thermal inertias inferred from multiple scenes for a given location could be attributed to sub-pixel grain size mixing rather than uncertainty inherent to the experiment, as previously thought. Mapping the difference in inferred thermal inertias from day and night THEMIS

  9. Normative values of isometric elbow strength in healthy adults: a systematic review.

    PubMed

    Kotte, Shamala H P; Viveen, Jetske; Koenraadt, Koen L M; The, Bertram; Eygendaal, Denise

    2018-07-01

    Post-traumatic deformities such as biceps tendon rupture or (peri-)articular fractures of the elbow are often related to a decrease in muscle strength. Postoperative evaluation of these deformities requires normative values of elbow strength. The purpose of this systematic review was to determine these normative values of isometric elbow strength in healthy adults resulting from studies evaluating this strength (i.e. flexion, extension, pronation and supination strength). The databases of PubMed, EMBASE and Web of Sciences were searched and screened for studies involving the isometric elbow strength as measured in asymptomatic volunteers. The quality of the studies was assessed and studies of low quality were excluded. Nineteen studies met the inclusion criteria and were of sufficiently high quality to be included in the present review. In these studies, elbow strength was measured in a total of 1880 healthy volunteers. The experimental set-up and devices used to measure elbow strength varied between studies. Using some assumptions, a normative values table was assembled. Large standard deviations of normative values in combination with different measurement devices used, as well as the different measurement positions of the subjects, demonstrated that there is no consensus about measuring the isometric elbow strength and therefore the normative values have to be interpreted with caution.

  10. [Prognostic value of first fasting glucose measurement compared with admission glucose level in patients with acute coronary syndrome].

    PubMed

    Vivas, David; García-Rubira, Juan C; González-Ferrer, Juan J; Núñez-Gil, Iván; del Prado, Náyade; Fernández-Ortiz, Antonio; Macaya, Carlos

    2008-05-01

    The admission plasma glucose (APG) level is a recognized prognostic factor in patients with acute coronary syndrome (ACS). However, little is known about the prognostic value of the first fasting plasma glucose (FPG) measurement. The aim of this study was to determine the prognostic value of the first FPG measurement relative to that of the APG level in patients with ACS. The study involved 547 consecutive patients who were admitted to our center with a diagnosis of ACS in 2006. Patients were divided into three groups according to their first FPG or APG level (i.e., <126 mg/dL, 126-200 mg/dL, or >200 mg/dL). The primary endpoint was the combined outcome of death or reinfarction during hospitalization. The primary endpoint was observed in 46 patients, 25 of whom died. Patients in this group were older, were more often diabetics or smokers, more often had had a prior myocardial infarction, were in a higher admission Killip class, showed more than one vessel disease on catheterization, had a lower left ventricular ejection fraction, and had higher admission creatinine, APG, and first FPG levels. Multivariate analysis, adjusted for previously identified factors, revealed that the first FPG level was an independent risk factor for death or reinfarction (126-200 mg/dL, odds ratio [OR]=5.26; 95% confidence interval [CI], 1.09-25.45; >200 mg/dL, OR=6.66; 95% CI, 2.05-21.63), but that the APG level was not (126-200 mg/dL, OR=0.84; 95% CI, 0.63-1.05; >200 mg/dL, OR=1.14; 95% CI, 0.29-4.51). The first FPG level was found to be a better predictor of an adverse outcome (i.e., death or reinfarction) during hospitalization in ACS patients than the APG level.

  11. [Value-based medicine in ophthalmology].

    PubMed

    Hirneiss, C; Neubauer, A S; Tribus, C; Kampik, A

    2006-06-01

    Value-based medicine (VBM) unifies costs and patient-perceived value (improvement in quality of life, length of life, or both) of an intervention. Value-based ophthalmology is of increasing importance for decisions in eye care. The methods of VBM are explained and definitions for a specific terminology in this field are given. The cost-utility analysis as part of health care economic analyses is explained. VBM exceeds evidence-based medicine by incorporating parameters of cost and benefits from an ophthalmological intervention. The benefit of the intervention is defined as an increase or maintenance of visual quality of life and can be determined by utility analysis. The time trade-off method is valid and reliable for utility analysis. The resources expended for the value gained in VBM are measured with cost-utility analysis in terms of cost per quality-adjusted life years gained (euros/QALY). Numerous cost-utility analyses of different ophthalmological interventions have been published. The fundamental instrument of VBM is cost-utility analysis. The results in cost per QALY allow estimation of cost effectiveness of an ophthalmological intervention. Using the time trade-off method for utility analysis allows the comparison of ophthalmological cost-utility analyses with those of other medical interventions. VBM is important for individual medical decision making and for general health care.

  12. The Value Profile of Physical Education Teachers in Taiwan, ROC

    ERIC Educational Resources Information Center

    Liu, Hsien-Yung; Silverman, Stephen

    2006-01-01

    The purpose of this study was to ascertain the educational value orientations of physical education teachers in Taiwan, and the relationships of gender, teaching experience, grade level, and the locations in which they work. Value orientations were measured with the Value Orientation Inventory-2, which was translated into complicated Chinese for…

  13. How Do We Value Postoperative Recovery?: A Systematic Review of the Measurement Properties of Patient-reported Outcomes After Abdominal Surgery.

    PubMed

    Fiore, Julio F; Figueiredo, Sabrina; Balvardi, Saba; Lee, Lawrence; Nauche, Bénédicte; Landry, Tara; Mayo, Nancy E; Feldman, Liane S

    2018-04-01

    To appraise the level of evidence supporting the measurement properties of patient-reported outcome measures (PROMs) in the context of postoperative recovery after abdominal surgery. There is growing interest in using PROMs to support value-based care in abdominal surgery; however, to draw valid conclusions regarding patient-reported outcomes data, PROMs with robust measurement properties are required. Eight databases (MEDLINE, EMBASE, Biosis, PsycINFO, The Cochrane Library, CINAHL, Scopus, Web of Science) were searched for studies focused on the measurement properties of PROMs in the context of recovery after abdominal surgery. The methodological quality of individual studies was evaluated using the consensus-based COSMIN checklist. Evidence supporting the measurement properties of each PROM was synthetized according to standardized criteria and compared against the International Society of Quality of Life Research minimum standards for the selection of PROMs for outcomes research. We identified 35 studies evaluating 22 PROMs [12 focused on nonspecific surgical populations (55%), 4 focused on abdominal surgery (18%), and 6 generic PROMs (27%)]. The great majority of the studies (74%) received only poor or fair quality ratings. Measurement properties of PROMs were predominantly supported by limited or unknown evidence. None of the PROMs fulfilled International Society of Quality of Life Research's minimum standards, hindering specific recommendations. There is very limited evidence supporting the measurement properties of existing PROMs used in the context of recovery after abdominal surgery. This precludes the use of these PROMs to support value-based surgical care. Further research is required to bridge this major knowledge gap. International Prospective Register of Systematic Reviews (PROSPERO): CRD42014014349.

  14. 16 CFR 460.5 - R-value tests.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... INSULATION 460.5 R-value tests. R-value measures resistance to heat flow. R-values given in labels, fact...) All types of insulation except aluminum foil must be tested with ASTM C 177-04, “Standard Test Method for Steady-State Heat Flux Measurements and Thermal Transmission Properties by Means of the Guarded...

  15. 16 CFR 460.5 - R-value tests.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... INSULATION 460.5 R-value tests. R-value measures resistance to heat flow. R-values given in labels, fact...) All types of insulation except aluminum foil must be tested with ASTM C 177-04, “Standard Test Method for Steady-State Heat Flux Measurements and Thermal Transmission Properties by Means of the Guarded...

  16. 16 CFR 460.5 - R-value tests.

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... INSULATION 460.5 R-value tests. R-value measures resistance to heat flow. R-values given in labels, fact...) All types of insulation except aluminum foil must be tested with ASTM C 177-04, “Standard Test Method for Steady-State Heat Flux Measurements and Thermal Transmission Properties by Means of the Guarded...

  17. 16 CFR 460.5 - R-value tests.

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... INSULATION 460.5 R-value tests. R-value measures resistance to heat flow. R-values given in labels, fact...) All types of insulation except aluminum foil must be tested with ASTM C 177-04, “Standard Test Method for Steady-State Heat Flux Measurements and Thermal Transmission Properties by Means of the Guarded...

  18. 16 CFR 460.5 - R-value tests.

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... INSULATION 460.5 R-value tests. R-value measures resistance to heat flow. R-values given in labels, fact...) All types of insulation except aluminum foil must be tested with ASTM C 177-04, “Standard Test Method for Steady-State Heat Flux Measurements and Thermal Transmission Properties by Means of the Guarded...

  19. Weak values in collision theory

    NASA Astrophysics Data System (ADS)

    de Castro, Leonardo Andreta; Brasil, Carlos Alexandre; Napolitano, Reginaldo de Jesus

    2018-05-01

    Weak measurements have an increasing number of applications in contemporary quantum mechanics. They were originally described as a weak interaction that slightly entangled the translational degrees of freedom of a particle to its spin, yielding surprising results after post-selection. That description often ignores the kinetic energy of the particle and its movement in three dimensions. Here, we include these elements and re-obtain the weak values within the context of collision theory by two different approaches, and prove that the results are compatible with each other and with the results from the traditional approach. To provide a more complete description, we generalize weak values into weak tensors and use them to provide a more realistic description of the Stern-Gerlach apparatus.

  20. Measurement of cochlear length using the 'A' value for cochlea basal diameter: A feasibility study.

    PubMed

    Deep, Nicholas L; Howard, Brittany E; Holbert, Sarah O; Hoxworth, Joseph M; Barrs, David M

    2017-07-01

    To determine whether the cochlea basal diameter (A value) measurement can be consistently and precisely obtained from high-resolution temporal bone imaging for use in cochlear length estimation. A feasibility study at a tertiary referral center was performed using the temporal bone CTs of 40 consecutive patients. The distance from the round window to the lateral wall was measured for each cochlea by two independent reviewers, a neuroradiologist and an otolaryngologist. The interrater reliability was calculated using the intraclass correlation coefficient (ICC) and the Bland-Altman plot. Forty patients (19 males, 21 females) for a total of 80 cochleae were included. Interrater reliability on the same ear had a high level of agreement by both the ICC and the Bland-Altman plot. ICCs were 0.90 (95% CI: 0.82, 0.94) for the left ear and 0.96 (95% CI: 0.92, 0.98) for the right ear. Bland-Altman plot confirmed interrater reliability with all 96% of measurements falling within the 95% limits of agreement. Measurement between the round window and lateral cochlear wall can be consistently and reliably obtained from high-resolution temporal bone CT scans. Thus, it is feasible to utilize this method to estimate the cochlear length of patients undergoing cochlear implantation.

  1. United States Population-Based Estimates of Patient-Reported Outcomes Measurement Information System Symptom and Functional Status Reference Values for Individuals With Cancer.

    PubMed

    Jensen, Roxanne E; Potosky, Arnold L; Moinpour, Carol M; Lobo, Tania; Cella, David; Hahn, Elizabeth A; Thissen, David; Smith, Ashley Wilder; Ahn, Jaeil; Luta, George; Reeve, Bryce B

    2017-06-10

    Purpose To estimate cancer population-based reference values in the United States for eight PROMIS (Patient-Reported Outcomes Measurement Information System) domains by age and stage of disease. Patients and Methods For the Measuring Your Health (MY-Health) study, persons newly diagnosed with cancer (prostate, colorectal, non-small-cell lung, non-Hodgkin lymphoma, breast, uterine, or cervical) from 2010 to 2012 (N = 5,284) were recruited through the National Cancer Institute's SEER Program. Participants were mailed surveys 6 to 13 months after diagnosis. Raking by race/ethnicity, age, and stage generated weighted average PROMIS scores for pain interference, fatigue, anxiety, depression, sleep disturbance, physical function, ability to participate in social roles, and cognitive function. PROMIS measures are standardized to a T-score metric, with a score of 50 representing the general US population mean. Clinically meaningful differences were defined as a 3-point difference in scores. Results Several reference values (means) for patients with cancer were worse than the general United States population norms of 50. These include pain interference (52.4), fatigue (52.2), and physical function (44.1). Reference values were highest (ie, showed greatest symptom burden) in lung cancer (pain interference, 55.5; fatigue, 57.3; depression, 51.4) and cervical cancer (anxiety, 53.2; sleep disturbance, 53.4). Reference values for patients age 65 to 84 years reported lower sleep disturbance, anxiety, and depression, and better cognitive function than younger patients. Cancer reference values were poorer among those with advanced disease compared with patients with limited or no evidence of disease, specifically physical function (41.1 v 46.6, respectively), fatigue (55.8 v 50.2, respectively), and pain interference (55.2 v 50.9, respectively). Conclusion In a large, population-based sample of patients with recently diagnosed cancer, we observed symptom severity and functional

  2. Measuring relative work values for home care nursing services in Japan.

    PubMed

    Ogata, Yasuko; Kobayashi, Yasuki; Fukuda, Takashi; Mori, Katsumi; Hashimoto, Michio; Otosaka, Kayo

    2004-01-01

    Japan's system of Home Visit Nursing Care Stations (Station) began in 1991. To maintain the quality of services in home health nursing provided by Stations, reimbursement needs to account not only for the number of home visits, but also for the time and intensity of nursing services. This study aimed primarily to investigate the total work value and the three dimensions (time, mental effort, and physical effort) of actual visiting nursing services for the aged, and to quantify the contribution made by the three dimensions of nursing services to total work. The secondary purpose was to determine whether patient characteristics, nurse characteristics, and types of nursing services contributed to the variance in total work. Total work is defined as comprehensive work input of nursing services, with careful consideration given to both the intensity and duration of work. Self-report questionnaires about actual visiting nursing services, based on the Resource-Based Relative Value Scale, were answered by 32 nurses from three Stations in urban Yokohama, Japan. Regression analysis showed that time and intensity (physical effort and mental effort) explained 96% the variance in total work. Time alone accounted for only 39% of the variance in total work. Patient characteristics, nurse characteristics, and service type accounted for less variance in total work than did time and intensity. The study findings indicate that reimbursement of nursing services should reflect not only the time required for each visit, but also the intensity of nursing services provided, including mental effort and physical effort.

  3. Gsolve, a Python computer program with a graphical user interface to transform relative gravity survey measurements to absolute gravity values and gravity anomalies

    NASA Astrophysics Data System (ADS)

    McCubbine, Jack; Tontini, Fabio Caratori; Stagpoole, Vaughan; Smith, Euan; O'Brien, Grant

    2018-01-01

    A Python program (Gsolve) with a graphical user interface has been developed to assist with routine data processing of relative gravity measurements. Gsolve calculates the gravity at each measurement site of a relative gravity survey, which is referenced to at least one known gravity value. The tidal effects of the sun and moon, gravimeter drift and tares in the data are all accounted for during the processing of the survey measurements. The calculation is based on a least squares formulation where the difference between the absolute gravity at each surveyed location and parameters relating to the dynamics of the gravimeter are minimized with respect to the relative gravity observations, and some supplied gravity reference site values. The program additionally allows the user to compute free air gravity anomalies, with respect to the GRS80 and GRS67 reference ellipsoids, from the determined gravity values and calculate terrain corrections at each of the surveyed sites using a prism formula and a user supplied digital elevation model. This paper reviews the mathematical framework used to reduce relative gravimeter survey observations to gravity values. It then goes on to detail how the processing steps can be implemented using the software.

  4. Demands, values, and burnout

    PubMed Central

    Leiter, Michael P.; Frank, Erica; Matheson, Timothy J.

    2009-01-01

    OBJECTIVE T o explore the interaction between workload and values congruence (personal values with health care system values) in the context of burnout and physician engagement and to explore the relative importance of these factors by sex, given the distinct work patterns of male and female physicians. DESIGN National mailed survey. SETTING Canada. PARTICIPANTS A random sample of 8100 Canadian physicians (response rate 40%, N = 3213); 2536 responses (from physicians working more than 35 hours per week) were analyzed. MAIN OUTCOME MEASURES Levels of burnout, values congruence, and workload, by sex, measured by the Maslach Burnout Inventory—General Scale and the Areas of Worklife Scale. RESULTS Results showed a moderate level of burnout among Canadian physicians, with relatively positive scores on exhaustion, average scores on cynicism, and mildly negative scores on professional efficacy. A series of multiple regression analyses confirmed parallel main effect contributions from manageable workload and values congruence. Both workload and values congruence predicted exhaustion and cynicism for men and women (P = .001). Only values congruence provided a significant prediction of professional efficacy for both men and women (P = .001) These predictors interacted for women on all 3 aspects of burnout (exhaustion, cynicism, and diminished efficacy). Howevever, overall levels of the burnout indicators departed only modestly from normative levels. CONCLUSION W orkload and values congruence make distinct contributions to physician burnout. Work overload contributes to predicting exhaustion and cynicism; professional values crises contribute to predicting exhaustion, cynicism, and low professional efficacy. The interaction of values and workload for women in particular has implications for the distinct work-life patterns of male and female physicians. Specifically, the congruence of individual values with values inherent in the health care system appeared to be of greater

  5. Existence Values for Groundwater (1989)

    EPA Pesticide Factsheets

    This study reports the findings of a preliminary investigation into the existence (nonuse) values people hold for groundwater resources and how these values can be measured for use in benefit/cost analysis.

  6. Value-based medicine: evidence-based medicine and beyond.

    PubMed

    Brown, Gary C; Brown, Melissa M; Sharma, Sanjay

    2003-09-01

    Value-based medicine is the practice of medicine emphasizing the value received from an intervention. Value is measured by objectively quantifying: 1) the improvement in quality of life and/or 2) the improvement in length of life conferred by an intervention. Evidence-based medicine often measures the improvement gained in length of life, but generally ignores the importance of quality of life improvement or loss. Value-based medicine incorporates the best features of evidence-based medicine and takes evidence-based data to a higher level by incorporating the quality of life perceptions of patients with a disease in concerning the value of an intervention. Inherent in value-based medicine are the costs associated with an intervention. The resources expended for the value gained in value-based medicine is measured with cost-utility analysis in terms of the US dollars/QALY (money spent per quality-adjusted life-year gained). A review of the current status and the likely future of value-based medicine is addressed herein.

  7. Measurements of Lifetimes and f-Values In Highly-Charged Ions

    NASA Astrophysics Data System (ADS)

    Smith, Steven; Chutjian, Ara; Hossain, Sabbir

    2006-05-01

    Measurements have been made of lifetimes of metastable levels of highly-charged ions (HCI). These contribute to the optical absorption, emission and energy balance in the ISM, stellar and solar atmospheres, etc. The experimental lifetime measurements are carried out using the 14.0 GHz electron cyclotron ion source at the JPL facility.[l] Ions are injected into a Kingdon ion trap and stored for times longer than the metastable lifetimes. Decay channels include inter-combination, E2, M1 and 2E transitions. The UV photons are filtered by an interference filter and detected by a UV grade photomultiplier tube using a UV grade optical system. The Kingdon trap was constructed in collaboration with Texas A and M University [2]. We previously have reported lifetimes for transitions of C^+ [1]and 0^2+ [4]. Additional metastable lifetimes have been measured for M^6+, Fe^9+, Fe^10+ and Fe^13+ metastable states [5]. New results for Fe^11+ will be presented. Sabbir Hossain acknowledges support through NASA-NRC program. This work was carried out at the Jet Propulsion Laboratory/Caltech and was supported by the NASA [1] Steven J. Smith, A. Chutjian, J.B. Greenwood, Phys. Rev. A 60, 3569 (1999). [2] L.Yang and D.A. Church, Phys. Rev. Lett. 70, 3860 (1993).[3] S.J. Smith, I. Cadez, A. Chutjian, and M. Niimura, Ap. J. 602, 1075 (2004).[5] S.J. Smith , A. Chutjian, J. Lozano, Phys Rev. A 72, 062504 (2005).

  8. Can Value-Added Measures of Teacher Performance Be Trusted?

    ERIC Educational Resources Information Center

    Guarino, Cassandra M.; Reckase, Mark D.; Wooldridge, Jeffrey M.

    2015-01-01

    We investigate whether commonly used value-added estimation strategies produce accurate estimates of teacher effects under a variety of scenarios. We estimate teacher effects in simulated student achievement data sets that mimic plausible types of student grouping and teacher assignment scenarios. We find that no one method accurately captures…

  9. Missing Value Monitoring Enhances the Robustness in Proteomics Quantitation.

    PubMed

    Matafora, Vittoria; Corno, Andrea; Ciliberto, Andrea; Bachi, Angela

    2017-04-07

    In global proteomic analysis, it is estimated that proteins span from millions to less than 100 copies per cell. The challenge of protein quantitation by classic shotgun proteomic techniques relies on the presence of missing values in peptides belonging to low-abundance proteins that lowers intraruns reproducibility affecting postdata statistical analysis. Here, we present a new analytical workflow MvM (missing value monitoring) able to recover quantitation of missing values generated by shotgun analysis. In particular, we used confident data-dependent acquisition (DDA) quantitation only for proteins measured in all the runs, while we filled the missing values with data-independent acquisition analysis using the library previously generated in DDA. We analyzed cell cycle regulated proteins, as they are low abundance proteins with highly dynamic expression levels. Indeed, we found that cell cycle related proteins are the major components of the missing values-rich proteome. Using the MvM workflow, we doubled the number of robustly quantified cell cycle related proteins, and we reduced the number of missing values achieving robust quantitation for proteins over ∼50 molecules per cell. MvM allows lower quantification variance among replicates for low abundance proteins with respect to DDA analysis, which demonstrates the potential of this novel workflow to measure low abundance, dynamically regulated proteins.

  10. Rate of value change in Pennsylvania timber stands

    Treesearch

    Owen W. Herrick

    1984-01-01

    Data from remeasured Pennsylvania forest inventory plots revealed that during a 13-year period the compound rate of value change in uncut hardwood forest stands averaged 4.7 percent, and ranged from -5.5 to 18.8 percent. No well-defined means for predicting a stand's rate of value change could be identified, However, some measures of initial stand condition can be...

  11. The Cucker-Smale Equation: Singular Communication Weight, Measure-Valued Solutions and Weak-Atomic Uniqueness

    NASA Astrophysics Data System (ADS)

    Mucha, Piotr B.; Peszek, Jan

    2018-01-01

    The Cucker-Smale flocking model belongs to a wide class of kinetic models that describe a collective motion of interacting particles that exhibit some specific tendency, e.g. to aggregate, flock or disperse. This paper examines the kinetic Cucker-Smale equation with a singular communication weight. Given a compactly supported measure as an initial datum we construct a global in time weak measure-valued solution in the space {C_{weak}(0,∞M)}. The solution is defined as a mean-field limit of the empirical distributions of particles, the dynamics of which is governed by the Cucker-Smale particle system. The studied communication weight is {ψ(s)=|s|^{-α}} with {α \\in (0,1/2)}. This range of singularity admits the sticking of characteristics/trajectories. The second result concerns the weak-atomic uniqueness property stating that a weak solution initiated by a finite sum of atoms, i.e. Dirac deltas in the form {m_i δ_{x_i} ⊗ δ_{v_i}}, preserves its atomic structure. Hence these coincide with unique solutions to the system of ODEs associated with the Cucker-Smale particle system.

  12. Age differences in personal values: Universal or cultural specific?

    PubMed

    Fung, Helene H; Ho, Yuan Wan; Zhang, Rui; Zhang, Xin; Noels, Kimberly A; Tam, Kim-Pong

    2016-05-01

    Prior studies on value development across adulthood have generally shown that as people age, they espouse communal values more strongly and agentic values less strongly. Two studies investigated whether these age differences in personal values might differ according to cultural values. Study 1 examined whether these age differences in personal values, and their associations with subjective well-being, showed the same pattern across countries that differed in individualism-collectivism. Study 2 compared age differences in personal values in the Canadian culture that emphasized agentic values more and the Chinese culture that emphasized communal values more. Personal and cultural values of each individual were directly measured, and their congruence were calculated and compared across age and cultures. Findings revealed that across cultures, older people had lower endorsement of agentic personal values and higher endorsement of communal personal values than did younger people. These age differences, and their associations with subjective well-being, were generally not influenced by cultural values. (PsycINFO Database Record (c) 2016 APA, all rights reserved).

  13. Human values in the team leader selection process.

    PubMed

    Rovira, Núria; Ozgen, Sibel; Medir, Magda; Tous, Jordi; Alabart, Joan Ramon

    2012-03-01

    The selection process of team leaders is fundamental if the effectiveness of teams is to be guaranteed. Human values have proven to be an important factor in the behaviour of individuals and leaders. The aim of this study is twofold. The first is to validate Schwartz's survey of human values. The second is to determine whether there are any relationships between the values held by individuals and their preferred roles in a team. Human values were measured by the items of the Schwartz Value Survey (SVS) and the preferred roles in a team were identified by the Belbin Self Perception Inventory (BSPI). The two questionnaires were answered by two samples of undergraduate students (183 and 177 students, respectively). As far as the first objective is concerned, Smallest Space Analysis (SSA) was performed at the outset to examine how well the two-dimensional circular structure, as postulated by Schwartz, was represented in the study population. Then, the results of this analysis were compared and contrasted with those of two other published studies; one by Schwartz (2006) and one by Ros and Grad (1991). As for the second objective, Pearson correlation coefficients were computed to assess the associations between the ratings on the SVS survey items and the ratings on the eight team roles as measured by the BSPI.

  14. Additional Value of CH4 Measurement in a Combined 13C/H2 Lactose Malabsorption Breath Test: A Retrospective Analysis

    PubMed Central

    Houben, Els; De Preter, Vicky; Billen, Jaak; Van Ranst, Marc; Verbeke, Kristin

    2015-01-01

    The lactose hydrogen breath test is a commonly used, non-invasive method for the detection of lactose malabsorption and is based on an abnormal increase in breath hydrogen (H2) excretion after an oral dose of lactose. We use a combined 13C/H2 lactose breath test that measures breath 13CO2 as a measure of lactose digestion in addition to H2 and that has a better sensitivity and specificity than the standard test. The present retrospective study evaluated the results of 1051 13C/H2 lactose breath tests to assess the impact on the diagnostic accuracy of measuring breath CH4 in addition to H2 and 13CO2. Based on the 13C/H2 breath test, 314 patients were diagnosed with lactase deficiency, 138 with lactose malabsorption or small bowel bacterial overgrowth (SIBO), and 599 with normal lactose digestion. Additional measurement of CH4 further improved the accuracy of the test as 16% subjects with normal lactose digestion and no H2-excretion were found to excrete CH4. These subjects should have been classified as subjects with lactose malabsorption or SIBO. In conclusion, measuring CH4-concentrations has an added value to the 13C/H2 breath test to identify methanogenic subjects with lactose malabsorption or SIBO. PMID:26371034

  15. Environments Perceived as Obesogenic Have Lower Residential Property Values

    PubMed Central

    Drewnowski, Adam; Aggarwal, Anju; Rehm, Colin D.; Cohen-Cline, Hannah; Hurvitz, Philip M.; Moudon, Anne V.

    2014-01-01

    Background Studies have tried to link multiple aspects of the built environment with physical activity and obesity rates. Purpose To determine the relation between residential property values and multiple perceived (self-reported) measures of the obesogenic environment. Methods The Seattle Obesity Study (SOS) used a telephone survey of a representative, geographically distributed sample of 2,001 King County adults, collected in 2008–2009 and analyzed in 2012–2013. Home addresses were geocoded. Residential property values at the tax parcel level were obtained from the King County tax assessor. Mean residential property values within a 10-minute walk (833-meter buffer) were calculated for each respondent. Data on multiple perceived measures of the obesogenic environment were collected by self-report. Correlations and multivariable linear regression analyses, stratified by residential density, were used to examine the associations among perceived environmental measures, property values, and BMI. Results Perceived measures of the environment such as crime, heavy traffic, and proximity to bars, liquor stores, and fast food were all associated with lower property values. By contrast, living in neighborhoods that were perceived as safe, quiet, clean, and attractive was associated with higher property values. Higher property values were associated, in turn, with lower BMIs. The observed associations between perceived environment measures and BMI were largely attenuated after accounting for residential property values. Conclusions Perceived measures of obesogenic environments are associated with lower property values. Studies in additional locations need to explore to what extent other perceived environment measures can be reflected in residential property values. PMID:25049218

  16. Colorimetric values of esthetic stainless steel crowns.

    PubMed

    Hosoya, Yumiko; Omachi, Koichi; Staninec, Michal

    2002-01-01

    The colorimetric values of two different kinds of esthetic stainless steel crowns were measured and compared with the colorimetric values of primary anterior teeth in Japanese children. The colorimetric values of resin composite-faced stainless steel crowns (Kinder Krown) and epoxy-coated stainless steel crowns (White Steel Crown) were measured with a color difference meter. The Commission Internationale de Eclairage L*, a*, b*, and delta E*ab values and Munsell value, chroma, and hue were calculated. The data were compared with previously reported colorimetric values of Japanese primary anterior teeth measured with the same color difference meter used in this study. Compared to Japanese primary anterior teeth, Kinder Krown Pedo I and Pedo II showed much higher L* values and lower hue; on the other hand, White Steel Crown showed much higher L*, a*, b* values, much higher value and chroma, and much lower hue. Color analysis revealed that the colors of the White Steel Crown and Kinder Krown Pedo I were substantially different from the color of Japanese primary anterior teeth. The color difference between Pedo II crowns and Japanese primary anterior teeth was relatively high, but the color of Pedo II might be acceptable for clinical use.

  17. The Role of Values in Preservice Teachers' Decision to Teach

    ERIC Educational Resources Information Center

    Torsney, Benjamin M.; Ponnock, Annette R.; Lombardi, Doug

    2017-01-01

    The current study explored the values preservice teachers use as motivation for pursuing a teaching career. Preservice teachers (N = 97) from a large Northeastern urban university were chosen to complete a survey measuring personal utility value, social utility value, and epistemic value. Data analysis was conducted using exploratory factor…

  18. Measuring the value of healthcare business assets.

    PubMed

    Evans, C J

    2000-04-01

    Healthcare organizations obtain valuations of business assets for many reasons, including to support decisions regarding potential mergers, sale of business components, or financing; for tax assessments; and for defense against law-suits. If compliance with regulations may be an issue, such as when a not-for-profit organization is involved in a transaction, healthcare organizations should seek an independent appraisal to ensure that applicable legal standards are met. Whether or not regulatory issues are involved, however, an accurate and useful valuation of business assets depends on many factors. Financial managers must understand the purpose and function of the valuation, choice of appropriate valuation techniques, proper assessment of intangible value, use of realistic growth rates, appropriate emphasis on key focus areas of the valuation (e.g., risk and future income streams), and an accounting of physician compensation.

  19. Measurement of Lactate Content and Amide Proton Transfer Values in the Basal Ganglia of a Neonatal Piglet Hypoxic-Ischemic Brain Injury Model Using MRI.

    PubMed

    Zheng, Y; Wang, X-M

    2017-04-01

    As amide proton transfer imaging is sensitive to protein content and intracellular pH, it has been widely used in the nervous system, including brain tumors and stroke. This work aimed to measure the lactate content and amide proton transfer values in the basal ganglia of a neonatal piglet hypoxic-ischemic brain injury model by using MR spectroscopy and amide proton transfer imaging. From 58 healthy neonatal piglets (3-5 days after birth; weight, 1-1.5 kg) selected initially, 9 piglets remained in the control group and 43 piglets, in the hypoxic-ischemic brain injury group. Single-section amide proton transfer imaging was performed at the coronal level of the basal ganglia. Amide proton transfer values of the bilateral basal ganglia were measured in all piglets. The ROI of MR spectroscopy imaging was the right basal ganglia, and the postprocessing was completed with LCModel software. After hypoxic-ischemic insult, the amide proton transfer values immediately decreased, and at 0-2 hours, they remained at their lowest level. Thereafter, they gradually increased and finally exceeded those of the control group at 48-72 hours. After hypoxic-ischemic insult, the lactate content increased immediately, was maximal at 2-6 hours, and then gradually decreased to the level of the control group. The amide proton transfer values were negatively correlated with lactate content ( r = -0.79, P < .05). This observation suggests that after hypoxic-ischemic insult, the recovery of pH was faster than that of lactate homeostasis. © 2017 by American Journal of Neuroradiology.

  20. Direct Measurement of the Mass Difference of 163Ho and 163Dy Solves the Q -Value Puzzle for the Neutrino Mass Determination

    NASA Astrophysics Data System (ADS)

    Eliseev, S.; Blaum, K.; Block, M.; Chenmarev, S.; Dorrer, H.; Düllmann, Ch. E.; Enss, C.; Filianin, P. E.; Gastaldo, L.; Goncharov, M.; Köster, U.; Lautenschläger, F.; Novikov, Yu. N.; Rischka, A.; Schüssler, R. X.; Schweikhard, L.; Türler, A.

    2015-08-01

    The atomic mass difference of 163 and 163Dy has been directly measured with the Penning-trap mass spectrometer SHIPTRAP applying the novel phase-imaging ion-cyclotron-resonance technique. Our measurement has solved the long-standing problem of large discrepancies in the Q value of the electron capture in 163Ho determined by different techniques. Our measured mass difference shifts the current Q value of 2555(16) eV evaluated in the Atomic Mass Evaluation 2012 [G. Audi et al., Chin. Phys. C 36, 1157 (2012)] by more than 7 σ to 2833 (30stat)(15sys) eV /c2 . With the new mass difference it will be possible, e.g., to reach in the first phase of the ECHo experiment a statistical sensitivity to the neutrino mass below 10 eV, which will reduce its present upper limit by more than an order of magnitude.

  1. How Teacher Evaluation Methods Matter for Accountability: A Comparative Analysis of Teacher Effectiveness Ratings by Principals and Teacher Value-Added Measures

    ERIC Educational Resources Information Center

    Harris, Douglas N.; Ingle, William K.; Rutledge, Stacey A.

    2014-01-01

    Policymakers are revolutionizing teacher evaluation by attaching greater stakes to student test scores and observation-based teacher effectiveness measures, but relatively little is known about why they often differ so much. Quantitative analysis of thirty schools suggests that teacher value-added measures and informal principal evaluations are…

  2. The Physician Values in Practice Scale: Construction and Initial Validation

    ERIC Educational Resources Information Center

    Hartung, Paul J.; Taber, Brian J.; Richard, George V.

    2005-01-01

    Measures of values typically appraise the construct globally, across life domains or relative to a broad life domain such as work. We conducted two studies to construct and initially validate an occupation- and context-specific values measure. Study 1, based on a sample of 192 medical students, describes the initial construction and item analysis…

  3. Measuring the Economic Value of Pre-MBA Work Experience

    ERIC Educational Resources Information Center

    Yeaple, Ronald N.; Johnston, Mark W.; Whittingham, Keith L.

    2010-01-01

    Pre-MBA work experience is required for admission to many graduate schools of business. In the present study, MBA graduates with a wide range of pre-MBA work experience were surveyed to assess the economic value of such work experience. No evidence was found of a systematic financial advantage to students from working for several years before…

  4. Relationships among values, achievement orientations, and attitudes in youth sport.

    PubMed

    Lee, Martin J; Whitehead, Jean; Ntoumanis, Nikos; Hatzigeorgiadis, Antonis

    2008-10-01

    This research examines the value-expressive function of attitudes and achievement goal theory in predicting moral attitudes. In Study 1, the Youth Sport Values Questionnaire (YSVQ; Lee, Whitehead, & Balchin, 2000) was modified to measure moral, competence, and status values. In Study 2, structural equation modeling on data from 549 competitors (317 males, 232 females) aged 12-15 years showed that moral and competence values predicted prosocial attitudes, whereas moral (negatively) and status values (positively) predicted antisocial attitudes. Competence and status values predicted task and ego orientation, respectively, and task and ego orientation partially mediated the effect of competence values on prosocial attitudes and of status values on antisocial attitudes, respectively. The role of sport values is discussed, and new research directions are proposed.

  5. Precise measurement of renal filtration and vascular parameters using a two-compartment model for dynamic contrast-enhanced MRI of the kidney gives realistic normal values.

    PubMed

    Tofts, Paul S; Cutajar, Marica; Mendichovszky, Iosif A; Peters, A Michael; Gordon, Isky

    2012-06-01

    To model the uptake phase of T(1)-weighted DCE-MRI data in normal kidneys and to demonstrate that the fitted physiological parameters correlate with published normal values. The model incorporates delay and broadening of the arterial vascular peak as it appears in the capillary bed, two distinct compartments for renal intravascular and extravascular Gd tracer, and uses a small-vessel haematocrit value of 24%. Four physiological parameters can be estimated: regional filtration K ( trans ) (ml min(-1) [ml tissue](-1)), perfusion F (ml min(-1) [100 ml tissue](-1)), blood volume v ( b ) (%) and mean residence time MRT (s). From these are found the filtration fraction (FF; %) and total GFR (ml min(-1)). Fifteen healthy volunteers were imaged twice using oblique coronal slices every 2.5 s to determine the reproducibility. Using parenchymal ROIs, group mean values for renal biomarkers all agreed with published values: K ( trans ): 0.25; F: 219; v ( b ): 34; MRT: 5.5; FF: 15; GFR: 115. Nominally cortical ROIs consistently underestimated total filtration (by ~50%). Reproducibility was 7-18%. Sensitivity analysis showed that these fitted parameters are most vulnerable to errors in the fixed parameters kidney T(1), flip angle, haematocrit and relaxivity. These renal biomarkers can potentially measure renal physiology in diagnosis and treatment. • Dynamic contrast-enhanced magnetic resonance imaging can measure renal function. • Filtration and perfusion values in healthy volunteers agree with published normal values. • Precision measured in healthy volunteers is between 7 and 15%.

  6. When it comes to measuring value, few HMOs can make the grade.

    PubMed

    MacStravic, S

    2001-01-01

    Like all organizations, managed care organizations (MCOs) must deliver value to customers, and to be sure of keeping them, ensure those customers know they have gained value. MCOs can choose any mix of insurance, protection, or experience value from particular encounters with customers, or durable value from their relationship with customers. Many have done a good job of tracking and enabling employers to appreciate the impact they have had on business performance, but few have done the same for the health and quality-of-life they deliver to consumers. MCOs already participate in the delivery of significant and enduring life value to consumers. It makes sense to track and remind consumers of the positive differences MCOs make, and thereby obtain member satisfaction, retention, and loyalty benefits, as well as image improvements for managed care as a whole. Some simple and inexpensive options for both tracking and reminding consumers are offered for consideration, including personalized annual health reports.

  7. Determining the value of disease management programs.

    PubMed

    Selby, Joe V; Scanlon, Dennis; Lafata, Jennifer Elston; Villagra, Victor; Beich, Jeff; Salber, Patricia R

    2003-09-01

    Increasing prevalence, rising costs, and persisting deficiencies in quality of care for chronic diseases pose economic and policy challenges to providers and purchasers. Disease management (DM) programs may address these challenges, but neither purchasers nor providers can assess their value. The potpourri of current quality indicators provides limited insight into the actual clinical benefit achieved. A conference sponsored by the Agency for Healthcare Research and Quality (AHRQ) and held in October 2002 explored new approaches to measuring and reporting the value of DM for diabetes mellitus. Quantifying the value of DM requires measuring clinical benefit and net impact on health care costs for the entire population with diabetes. If quality is measured with indicators that are clearly linked to outcomes, clinical benefit can be estimated. Natural history models combine the expected benefits of improvements in multiple indicators to yield a single, composite measure, the quality-adjusted life-year. Such metrics could fairly express, in terms of survival and complications prevention, relatively disparate DM programs' benefits. Measuring and comparing health care costs requires data validation and appropriate case-mix adjustment. Comparing value across programs may provide more accurate assessments of performance, enhance quality improvement efforts within systems, and contribute generalizable knowledge on the utility of DM approaches. Conference attendees recommended pilot projects to further explore use of natural history models for measuring and reporting the value of DM.

  8. Measuring the Value of Mortality Risk Reductions in Turkey

    PubMed Central

    Tekeşin, Cem; Ara, Shihomi

    2014-01-01

    The willingness to pay (WTP) for mortality risk reduction from four causes (lung cancer, other type of cancer, respiratory disease, traffic accident) are estimated using random parameter logit model with data from choice experiment for three regions in Turkey. The value of statistical life (VSL) estimated for Afsin-Elbistan, Kutahya-Tavsanli, Ankara and the pooled case are found as 0.56, 0.35, 0.46 and 0.49 million Purchasing Power Parity (PPP) adjusted 2012 US dollars (USD). Different types of risk cause different VSL estimates and we found the lung cancer premium of 213% against traffic accident. The effects of one-year-delayed provision of risk-reduction service are the reduction of WTP by 482 TL ($318 in PPP adjusted USD) per person on average, and the disutility from status-quo (zero risk reduction) against alternative is found to be 891 TL ($589 in PPP adjusted USD) per person on average. Senior discounts of VSL are partially determined by status-quo preference and the amount of discount decreases once the status-quo bias is removed. The peak VSL is found to be for the age group 30–39 and the average VSL for the age group is 0.8 million PPP adjusted USD). Turkey’s compliance to European Union (EU) air quality standard will cause welfare gains of total 373 million PPP adjusted USD for our study areas in terms of reduced number of premature mortality. PMID:25000150

  9. Evaluation of assigned-value uncertainty for complex calibrator value assignment processes: a prealbumin example.

    PubMed

    Middleton, John; Vaks, Jeffrey E

    2007-04-01

    Errors of calibrator-assigned values lead to errors in the testing of patient samples. The ability to estimate the uncertainties of calibrator-assigned values and other variables minimizes errors in testing processes. International Organization of Standardization guidelines provide simple equations for the estimation of calibrator uncertainty with simple value-assignment processes, but other methods are needed to estimate uncertainty in complex processes. We estimated the assigned-value uncertainty with a Monte Carlo computer simulation of a complex value-assignment process, based on a formalized description of the process, with measurement parameters estimated experimentally. This method was applied to study uncertainty of a multilevel calibrator value assignment for a prealbumin immunoassay. The simulation results showed that the component of the uncertainty added by the process of value transfer from the reference material CRM470 to the calibrator is smaller than that of the reference material itself (<0.8% vs 3.7%). Varying the process parameters in the simulation model allowed for optimizing the process, while keeping the added uncertainty small. The patient result uncertainty caused by the calibrator uncertainty was also found to be small. This method of estimating uncertainty is a powerful tool that allows for estimation of calibrator uncertainty for optimization of various value assignment processes, with a reduced number of measurements and reagent costs, while satisfying the requirements to uncertainty. The new method expands and augments existing methods to allow estimation of uncertainty in complex processes.

  10. Improving health care, Part 1: The clinical value compass.

    PubMed

    Nelson, E C; Mohr, J J; Batalden, P B; Plume, S K

    1996-04-01

    CLINICAL VALUE COMPASS APPROACH: The clinical Value Compass, named to reflect its similarity in layout to a directional compass, has at its four cardinal points (1) functional status, risk status, and well-being; (2) costs; (3) satisfaction with health care and perceived benefit; and (4) clinical outcomes. To manage and improve the value of health care services, providers will need to measure the value of care for similar patient populations, analyze the internal delivery processes, run tests of changed delivery processes, and determine if these changes lead to better outcomes and lower costs. GETTING STARTED--OUTCOMES AND AIM: In the case example, the team's aim is "to find ways to continually improve the quality and value of care for AMI (acute myocardial infection) patients." VALUE MEASURES--SELECT A SET OF OUTCOME AND COST MEASURES: Four to 12 outcome and cost measures are sufficient to get started. In the case example, the team chose 1 or more measures for each quadrant of the value compass. An operational definition is a clearly specified method explaining how to measure a variable. Measures in the case example were based on information from the medical record, administrative and financial records, and patient reports and ratings at eight weeks postdischarge. Measurement systems that quantify the quality of processes and results of care are often add-ons to routine care delivery. However, the process of measurement should be intertwined with the process of care delivery so that front-line providers are involved in both managing the patient and measuring the process and related outcomes and costs.

  11. Values taught, values learned, attitude and performance in mathematics

    NASA Astrophysics Data System (ADS)

    Limbaco, K. S. A.

    2015-03-01

    The purpose of the study was to identify, describe and find the relationship among values taught, values learned, attitude and performance in mathematics. The researcher used descriptive-correlational method of research to gather information and to describe the nature of situation. The following instruments were used in this study: Math Attitude Inventory, Inventory of Values Taught and Learned which were content validated by experts in the field of Mathematics, Values and Education. Generally, most of the values were taught by the teachers. All of the values were learned by the students. The following got the highest mean ratings for values taught: moral strength, sharing, charity, valuing life, love of God, truth and honesty, reason, alternativism and articulation. The following got highest mean ratings for values learned: patience/tolerance, sharing, charity, valuing life, faith, love of God, truth and honesty, analogical thinking, confidence and individual liberty. Majority of the respondents have moderately positive attitude towards mathematics. Positive statements in the Mathematics Attitude Inventory are "Generally true" while negative statements are "Neutral." In conclusion, values were taught by mathematics teacher, thus, learned by the students. Therefore, mathematics is very much related to life. Values can be learned and strengthened through mathematics; there is a significant relationship between values taught by the teachers and values learned by the students and attitude towards mathematics and performance in mathematics; values taught does not affect attitude towards mathematics and performance in mathematics. A student may have a positive attitude towards mathematics or have an exemplary performance in mathematics even if the mathematics teacher did not teach values; values learned does not affect attitude towards mathematics and performance in mathematics. A student may have a positive attitude towards mathematics or have an exemplary performance

  12. Partial volume correction and image segmentation for accurate measurement of standardized uptake value of grey matter in the brain.

    PubMed

    Bural, Gonca; Torigian, Drew; Basu, Sandip; Houseni, Mohamed; Zhuge, Ying; Rubello, Domenico; Udupa, Jayaram; Alavi, Abass

    2015-12-01

    Our aim was to explore a novel quantitative method [based upon an MRI-based image segmentation that allows actual calculation of grey matter, white matter and cerebrospinal fluid (CSF) volumes] for overcoming the difficulties associated with conventional techniques for measuring actual metabolic activity of the grey matter. We included four patients with normal brain MRI and fluorine-18 fluorodeoxyglucose (F-FDG)-PET scans (two women and two men; mean age 46±14 years) in this analysis. The time interval between the two scans was 0-180 days. We calculated the volumes of grey matter, white matter and CSF by using a novel segmentation technique applied to the MRI images. We measured the mean standardized uptake value (SUV) representing the whole metabolic activity of the brain from the F-FDG-PET images. We also calculated the white matter SUV from the upper transaxial slices (centrum semiovale) of the F-FDG-PET images. The whole brain volume was calculated by summing up the volumes of the white matter, grey matter and CSF. The global cerebral metabolic activity was calculated by multiplying the mean SUV with total brain volume. The whole brain white matter metabolic activity was calculated by multiplying the mean SUV for the white matter by the white matter volume. The global cerebral metabolic activity only reflects those of the grey matter and the white matter, whereas that of the CSF is zero. We subtracted the global white matter metabolic activity from that of the whole brain, resulting in the global grey matter metabolism alone. We then divided the grey matter global metabolic activity by grey matter volume to accurately calculate the SUV for the grey matter alone. The brain volumes ranged between 1546 and 1924 ml. The mean SUV for total brain was 4.8-7. Total metabolic burden of the brain ranged from 5565 to 9617. The mean SUV for white matter was 2.8-4.1. On the basis of these measurements we generated the grey matter SUV, which ranged from 8.1 to 11.3. The

  13. Accounting for People: Can Business Measure Human Value?

    ERIC Educational Resources Information Center

    Workforce Economics, 1997

    1997-01-01

    Traditional business practice undervalues human capital, and most conventional accounting models reflect this inclination. The argument for more explicit measurements of human resources is simple: Improved measurement of human resources will lead to more rational and productive choices about managing human resources. The business community is…

  14. [QUALITY MEASURES IN MEDICINE-- A PLEA FOR NEW, VALUE BASED THINKING].

    PubMed

    Fisher, Menachem; Wagner, Oded; Keinarl, Talia; Solt, Ido

    2015-09-01

    Quality is an important and basic conduct of complex systems in general and health systems in particular. Quality is a cornerstone of medicine, necessary in the eyes of the community of consumers, caregivers, and the systems that manage both. In Israel, the Ministry of Health has set the quality issue on the agenda of healthcare organizations in all existing frameworks. In this article we seek to offer an acceptable alternative perspective, in examining the quality of public health. We suggest highlighting the ethical aspect of medical care, while reducing the quantitative monitoring component of existing quality metrics. Relying solely on indices has negative effects that might cause damage. The proposed alternative focuses on the personal responsibility of health care providers, using. values and moral reasonin.

  15. Value-Based Argumentation for Justifying Compliance

    NASA Astrophysics Data System (ADS)

    Burgemeestre, Brigitte; Hulstijn, Joris; Tan, Yao-Hua

    Compliance is often achieved 'by design' through a coherent system of controls consisting of information systems and procedures . This system-based control requires a new approach to auditing in which companies must demonstrate to the regulator that they are 'in control'. They must determine the relevance of a regulation for their business, justify which set of control measures they have taken to comply with it, and demonstrate that the control measures are operationally effective. In this paper we show how value-based argumentation theory can be applied to the compliance domain. Corporate values motivate the selection of control measures (actions) which aim to fulfill control objectives, i.e. adopted norms (goals). In particular, we show how to formalize the dialogue in which companies justify their compliance decisions to regulators using value-based argumentation. The approach is illustrated by a case study of the safety and security measures adopted in the context of EU customs regulation.

  16. Nursing values and a changing nurse workforce: values, age, and job stages.

    PubMed

    McNeese-Smith, Donna K; Crook, Mary

    2003-05-01

    To identify the extent values are associated with age group and job stage; job satisfaction, productivity, and organizational commitment; as well as education, generation, ethnicity, gender, and role. Values direct the priorities we live by and are related to employee loyalty and commitment. Lack of congruency between a nurse's personal values and those of the organization decrease satisfaction and effectiveness and may lead to burnout and turnover. Little research has been done on whether values differ by age, generations, or job stages. Nurses in all roles (N = 412) in three hospitals in Los Angeles County were randomly surveyed, using valid and reliable instruments to measure the variables of interest. Nurses in the top third for job satisfaction, organizational commitment, and productivity showed higher scores for many values including their associates, creativity, esthetics, and management, while those in the bottom third scored higher in economic returns only. Nurses in different generations differed little; younger generations placed higher values on economic returns and variety. Management strategies to meet nurses' values and increase their satisfaction and retention are presented.

  17. Optimizing value utilizing Toyota Kata methodology in a multidisciplinary clinic.

    PubMed

    Merguerian, Paul A; Grady, Richard; Waldhausen, John; Libby, Arlene; Murphy, Whitney; Melzer, Lilah; Avansino, Jeffrey

    2015-08-01

    Value in healthcare is measured in terms of patient outcomes achieved per dollar expended. Outcomes and cost must be measured at the patient level to optimize value. Multidisciplinary clinics have been shown to be effective in providing coordinated and comprehensive care with improved outcomes, yet tend to have higher cost than typical clinics. We sought to lower individual patient cost and optimize value in a pediatric multidisciplinary reconstructive pelvic medicine (RPM) clinic. The RPM clinic is a multidisciplinary clinic that takes care of patients with anomalies of the pelvic organs. The specialties involved include Urology, General Surgery, Gynecology, and Gastroenterology/Motility. From May 2012 to November 2014 we performed time-driven activity-based costing (TDABC) analysis by measuring provider time for each step in the patient flow. Using observed time and the estimated hourly cost of each of the providers we calculated the final cost at the individual patient level, targeting clinic preparation. We utilized Toyota Kata methodology to enhance operational efficiency in an effort to optimize value. Variables measured included cost, time to perform a task, number of patients seen in clinic, percent value-added time (VAT) to patients (face to face time) and family experience scores (FES). At the beginning of the study period, clinic costs were $619 per patient. We reduced conference time from 6 min/patient to 1 min per patient, physician preparation time from 8 min to 6 min and increased Medical Assistant (MA) preparation time from 9.5 min to 20 min, achieving a cost reduction of 41% to $366 per patient. Continued improvements further reduced the MA preparation time to 14 min and the MD preparation time to 5 min with a further cost reduction to $194 (69%) (Figure). During this study period, we increased the number of appointments per clinic. We demonstrated sustained improvement in FES with regards to the families overall experience with their providers

  18. A sipometer for measuring motivation to consume and reward value of foods and beverages in humans: Description and proof of principle.

    PubMed

    Hogenkamp, P S; Shechter, A; St-Onge, M-P; Sclafani, A; Kissileff, H R

    2017-03-15

    New methods, derived from animal work, for measuring food reward value (i.e. reinforcing value of food), and motivation (i.e. strength of desire) to consume, in humans are described and validated. A sipping device (sipometer) was developed that permits access to a liquid food or beverage on two reward schedules: continuous reinforcement (CR) and progressively increasing time spent exerting pressure on a straw (PR-schedule). In addition, a pictorial scale showing a cup, from which the 'amount wanted' could be marked was used to pre-test potential consumption. Intake, time spent sipping, breakpoint, and pressure exerted were the main dependent variables measured. Three pilot experiments were conducted. In Experiment 1, participants (n=8) consumed yogurt shakes after a 1-h or 21-h food deprivation period on both schedules. In Experiment 2, participants (n=8) sham-consumed (i.e. spit out) sweet and non-sweet beverages, utilizing both schedules. In Experiment 3, sham-consuming sweet and non-sweet beverages on both schedules and working for shake on the PR schedule were repeated, after three nights of either habitual sleep or short sleep duration (n=7) in a crossover design. In Experiment 1, participants sipped longer after 21-h vs. 1-h of food deprivation (13±3.0 vs. 8.0±2.1s; p=0.04), on the PR schedule. In Experiment 2, sham-intake (p=0.01) and sipping time (p=0.04) were greater for sweet than non-sweet beverages on the PR schedule and a similar, though not conventionally significant, effect was observed for exerted pressure (p=0.09). In both Experiment 2 and Experiment 3 after habitual sleep, on the PR schedule, cumulative pressure difference between sweet and non-sweet beverage increased with difference in amount wanted in the taste test. In contrast, after short sleep participants were less willing to work for sweet taste as their wanting increased, suggesting that sleep deprivation raises desire, but lowers behavioral output. Taken together these results

  19. A sipometer for measuring motivation to consume and reward value of foods and beverages in humans: Description and proof of principle

    PubMed Central

    Hogenkamp, PS; Shechter, A.; St-Onge, M-P; Sclafani, A; Kissileff, HR

    2017-01-01

    New methods, derived from animal work, for measuring food reward value (i.e. reinforcing value of food), and motivation (i.e. strength of desire) to consume, in humans are described and validated. A sipping device (sipometer) was developed that permits access to a liquid food or beverage on two reward schedules: continuous reinforcement (CR) and progressively increasing time spent exerting pressure on a straw (PR-schedule). In addition, a pictorial scale showing a cup, from which the ‘amount wanted’ could be marked was used to pre-test potential consumption. Intake, time spent sipping, breakpoint, and pressure exerted were the main dependent variables measured. Three pilot experiments were conducted. In Experiment 1, participants (n = 8) consumed yogurt shakes after a 1-h or 21-h food deprivation period on both schedules. In Experiment 2, participants (n = 8) sham-consumed (i.e. spit out) sweet and non-sweet beverages, utilizing both schedules. In Experiment 3, sham-consuming sweet and non-sweet beverages on both schedules and working for shake on the PR schedule were repeated, after three nights of either habitual sleep or short sleep duration (n = 7) in a crossover design. In Experiment 1, participants sipped longer after 21-h vs. 1-h of food deprivation (13 ± 3.0 vs. 8.0 ± 2.1 s; p = 0.04), on the PR schedule. In Experiment 2, sham-intake (p = 0.01) and sipping time (p = 0.04) were greater for sweet than non-sweet beverages on the PR schedule and a similar, though not conventionally significant, effect was observed for exerted pressure (p = 0.09). In both Experiment 2 and Experiment 3 after habitual sleep, on the PR schedule, cumulative pressure difference between sweet and non-sweet beverage increased with difference in amount wanted in the taste test. In contrast, after short sleep participants were less willing to work for sweet taste as their wanting increased, suggesting that sleep deprivation raises desire, but lowers behavioral output. Taken

  20. Value-Added to What? How a Ceiling in the Testing Instrument Influences Value-Added Estimation. NBER Working Paper No. 14778

    ERIC Educational Resources Information Center

    Koedel, Cory; Betts, Julian

    2009-01-01

    Value-added measures of teacher quality may be sensitive to the quantitative properties of the student tests upon which they are based. This paper focuses on the sensitivity of value- added to test-score-ceiling effects. Test-score ceilings are increasingly common in testing instruments across the country as education policy continues to emphasize…

  1. Global Value Trees

    PubMed Central

    Zhu, Zhen; Puliga, Michelangelo; Cerina, Federica; Chessa, Alessandro; Riccaboni, Massimo

    2015-01-01

    The fragmentation of production across countries has become an important feature of the globalization in recent decades and is often conceptualized by the term “global value chains” (GVCs). When empirically investigating the GVCs, previous studies are mainly interested in knowing how global the GVCs are rather than how the GVCs look like. From a complex networks perspective, we use the World Input-Output Database (WIOD) to study the evolution of the global production system. We find that the industry-level GVCs are indeed not chain-like but are better characterized by the tree topology. Hence, we compute the global value trees (GVTs) for all the industries available in the WIOD. Moreover, we compute an industry importance measure based on the GVTs and compare it with other network centrality measures. Finally, we discuss some future applications of the GVTs. PMID:25978067

  2. Determination of threshold value of soil water content for field and vegetable plants with lysimeter measurements

    NASA Astrophysics Data System (ADS)

    Knoblauch, S.

    2009-04-01

    Both the potential water consumption of plants and their ability to withdraw soil water are necessary in order to estimate actual evapotranspiration and to predict irrigation timing and amount. In relating to root water uptake the threshold value at which plants reducing evapotranspiration is an important parameter. Since transpiration is linearly correlated to dry matter production, under the condition that the AET/PET-Quotient is smaller than 1.0 (de Wit 1958, Tanner & Sinclair 1983), the dry matter production begins to decline too. Plants respond to drought with biochemical, physiological and morphological modifications in order to avoid damages, for instance by increasing the root water uptake. The objective of the study is to determine threshold values of soil water content and pressure head respectively for different field and vegetable plants with lysimeter measurements and to derive so called reduction functions. Both parameter, potenzial water demand in several growth stages and threshold value of soil water content or pressure head can be determined with weighable field lysimeter. The threshold value is reached, when the evapotranspiration under natural rainfall condition (AET) drop clearly (0.8 PET) below the value under well watered condition (PET). Basis for the presented results is the lysimeter plant Buttelstedt of the Thuringian State Institute of Agriculture. It consist of two lysimeter cellars, each with two weighable monolithic lysimeters. The lysimeter are 2.5 m deep with a surface area of 2 m2 to allow a non-restrictive root growth and to arrange a representative number of plants. The weighing accuracy amounts to 0.05 mm. The percolating water is collected by ceramic suction cups with suction up to 0.3 MPa at a depth of 2.3 m. The soil water content is measured by using neutron probe. One of the two lysimeter cellars represents the will irrigated, the other one the non irrigated and/or reduced irrigated part of field. The soil is a Haplic

  3. Resolving model parameter values from carbon and nitrogen stock measurements in a wide range of tropical mature forests using nonlinear inversion and regression trees

    Treesearch

    Shuguang Liua; Pamela Anderson; Guoyi Zhoud; Boone Kauffman; Flint Hughes; David Schimel; Vicente Watson; Joseph Tosi

    2008-01-01

    Objectively assessing the performance of a model and deriving model parameter values from observations are critical and challenging in landscape to regional modeling. In this paper, we applied a nonlinear inversion technique to calibrate the ecosystem model CENTURY against carbon (C) and nitrogen (N) stock measurements collected from 39 mature tropical forest sites in...

  4. Exploring experiential value in online mobile gaming adoption.

    PubMed

    Okazaki, Shintaro

    2008-10-01

    Despite the growing importance of the online mobile gaming industry, little research has been undertaken to explain why consumers engage in this ubiquitous entertainment. This study attempts to develop an instrument to measure experiential value in online mobile gaming adoption. The proposed scale consists of seven first-order factors of experiential value: intrinsic enjoyment, escapism, efficiency, economic value, visual appeal, perceived novelty, and perceived risklessness. The survey obtained 164 usable responses from Japanese college students. The empirical data fit our first-order model well, indicating a high level of reliability as well as convergent and discriminant validity. The single second-order model also shows an acceptable model fit.

  5. Memory for general and specific value information in younger and older adults: measuring the limits of strategic control.

    PubMed

    Castel, Alan D; Farb, Norman A S; Craik, Fergus I M

    2007-06-01

    The ability to selectively remember important information is a critical function of memory. Although previous research has suggested that older adults are impaired in a variety of episodic memory tasks, recent work has demonstrated that older adults can selectively remember high-value information. In the present research, we examined how younger and older adults selectively remembered words with various assigned numeric point values, to see whether younger adults could remember more specific value information than could older adults. Both groups were equally good at recalling point values when recalling the range of high-value words, but younger adults outperformed older adults when recalling specific values. Although older adults were more likely to recognize negative value words, both groups exhibited control by not recalling negative value information. The findings suggest that although both groups retain high-value information, older adults rely more on gist-based encoding and retrieval operations, whereas younger adults are able to remember specific numeric value information.

  6. Defining and Delivering Measurable Value: A Mega Thinking and Planning Primer

    ERIC Educational Resources Information Center

    Kaufman, Roger

    2005-01-01

    Mega planning has a primary focus on adding value for all stakeholders. It is realistic, practical, and ethical. Denning and then achieving sustained organizational success is possible. It relies on three basic elements: (1) "A societal value-added "frame of mind" or paradigm": your perspective about your organization, people, and our world. It…

  7. Does the Market Value Value-Added? Evidence from Housing Prices after a Public Release of School and Teacher Value-Added. Working Paper #47

    ERIC Educational Resources Information Center

    Imberman, Scott; Lovenheim, Michael F.

    2015-01-01

    Value-added data have become an increasingly common evaluation tool for schools and teachers. Many school districts have begun to adopt these methods and have released results publicly. In this paper, we use the unique public release of value-added data in Los Angeles to identify how this measure of school quality is capitalized into housing…

  8. The Mathematics Values in Classroom Inventory: Development and Initial Validation

    ERIC Educational Resources Information Center

    Tapsir, Ruzela; Nik Azis, Nik Pa

    2017-01-01

    Value has been identified as an essential aspect towards the quality in mathematics education at various levels of the system, institutional, curriculum, education management, and classroom interactions. However, few studies were focused on values, its development, measurement, and impact in education as compared to other affective aspects such as…

  9. The value of health care--a matter of discussion in Germany.

    PubMed

    Porzsolt, Franz; Ackermann, Moritz; Amelung, Volker

    2007-01-02

    Interest in assessing the value of health-care services in Germany has considerably increased since the foundation of the Institut für Qualität und Wirtschaftlichkeit im Gesundheitswesen, IQWiG (Institute for Quality and Efficiency in Health Care). The practical application of value assessment illustrates how problematic the process can be. In all decisions made for the provision of health care, data concerning the measurable dimensions (quantity and quality of efficacy and effectiveness, validity of the results and costs) flow into a complex and not yet standardized decision-making process concerning public financing. Some of these decisions are based on data of uncertain validity, unknown reproducibility and unclear appropriateness. In this paper we describe the theoretical aspects of value from psychological and economic viewpoints and discuss national and international approaches. Methodic details and difficulties in assessing the value of health-care services are analysed. A definition of the intangible value of health-care services will be proposed which contains only three factors: the absolute risk reduction (usually a measure of efficacy), the validity of the scientific papers examined and the type of the expected effectiveness (prevention of death and disability, restitution of well-being). The intangible value describes the additional benefit when comparing two possible actions, like treatment or observation only. The description of intangible value from the viewpoint of different stakeholders is a useful measure for subsequent steps (not discussed here) - the evaluation of costs and of patient benefit. A standardised, transparent, fair and democratic evaluation is essential for the definition of a basic benefit package.

  10. Resolving model parameter values from carbon and nitrogen stock measurements in a wide range of tropical mature forests using nonlinear inversion and regression trees

    USGS Publications Warehouse

    Liu, S.; Anderson, P.; Zhou, G.; Kauffman, B.; Hughes, F.; Schimel, D.; Watson, Vicente; Tosi, Joseph

    2008-01-01

    Objectively assessing the performance of a model and deriving model parameter values from observations are critical and challenging in landscape to regional modeling. In this paper, we applied a nonlinear inversion technique to calibrate the ecosystem model CENTURY against carbon (C) and nitrogen (N) stock measurements collected from 39 mature tropical forest sites in seven life zones in Costa Rica. Net primary productivity from the Moderate-Resolution Imaging Spectroradiometer (MODIS), C and N stocks in aboveground live biomass, litter, coarse woody debris (CWD), and in soils were used to calibrate the model. To investigate the resolution of available observations on the number of adjustable parameters, inversion was performed using nine setups of adjustable parameters. Statistics including observation sensitivity, parameter correlation coefficient, parameter sensitivity, and parameter confidence limits were used to evaluate the information content of observations, resolution of model parameters, and overall model performance. Results indicated that soil organic carbon content, soil nitrogen content, and total aboveground biomass carbon had the highest information contents, while measurements of carbon in litter and nitrogen in CWD contributed little to the parameter estimation processes. The available information could resolve the values of 2-4 parameters. Adjusting just one parameter resulted in under-fitting and unacceptable model performance, while adjusting five parameters simultaneously led to over-fitting. Results further indicated that the MODIS NPP values were compressed as compared with the spatial variability of net primary production (NPP) values inferred from inverse modeling. Using inverse modeling to infer NPP and other sensitive model parameters from C and N stock observations provides an opportunity to utilize data collected by national to regional forest inventory systems to reduce the uncertainties in the carbon cycle and generate valuable

  11. Reference value of impulse oscillometry in taiwanese preschool children.

    PubMed

    Lai, Shen-Hao; Yao, Tsung-Chieh; Liao, Sui-Ling; Tsai, Ming-Han; Hua, Men-Chin; Yeh, Kuo-Wei; Huang, Jing-Long

    2015-06-01

    Impulse oscillometry is a potential technique for assessing the respiratory mechanism-which includes airway resistance and reactance during tidal breathing-in minimally cooperative young children. The reference values available in Asian preschool children are limited, especially in children of Chinese ethnicity. This study aimed to develop reference equations for lung function measurements using impulse oscillometry in Taiwanese children for future clinical application and research exploitation. Impulse oscillometry was performed in 150 healthy Taiwanese children (aged 2-6 years) to measure airway resistance and reactance at various frequencies. We used regression analysis to generate predictive equations separately by age, body height, body weight, and gender. The stepwise regression model revealed that body height was the most significant determinant of airway resistance and reactance in preschool young children. With the growth in height, a decrease in airway resistance and a paradoxical increase in reactance occurred at different frequencies. The regression curve of resistance at 5 Hz was comparable to previous reference values. This study provided reference values for several variables of the impulse oscillometry measurements in healthy Taiwanese children aged 2-6 years. With these reference data, clinical application of impulse oscillometry would be expedient in diagnosing respiratory diseases in preschool children. Copyright © 2014. Published by Elsevier B.V.

  12. Probabilistic Teleportation of an Arbitrary Two-Qubit State via Positive Operator-Valued Measurement with Multi Parties

    NASA Astrophysics Data System (ADS)

    Shi, Lei; Wei, Jia-Hua; Li, Yun-Xia; Ma, Li-Hua; Xue, Yang; Luo, Jun-Wen

    2017-04-01

    We propose a novel scheme to probabilistically transmit an arbitrary unknown two-qubit quantum state via Positive Operator-Valued Measurement with the help of two partially entangled states. In this scheme, the teleportation with two senders and two receives can be realized when the information of non-maximally entangled states is only available for the senders. Furthermore, the concrete implementation processes of this proposal are presented, meanwhile the classical communication cost and the successful probability of our scheme are calculated. Supported by the National Natural Science Foundation of China under Grant Nos. 60974037, 61134008, 11074307, and 61273202

  13. Business marketing: understand what customers value.

    PubMed

    Anderson, J C; Narus, J A

    1998-01-01

    How do you define the value of your market offering? Can you measure it? Few suppliers in business markets are able to answer those questions, and yet the ability to pinpoint the value of a product or service for one's customers has never been more important. By creating and using what the authors call customer value models, suppliers are able to figure out exactly what their offerings are worth to customers. Field value assessments--the most commonly used method for building customer value models--call for suppliers to gather data about their customers firsthand whenever possible. Through these assessments, a supplier can build a value model for an individual customer or for a market segment, drawing on data gathered form several customers in that segment. Suppliers can use customer value models to create competitive advantage in several ways. First, they can capitalize on the inevitable variation in customers' requirements by providing flexible market offerings. Second, they can use value models to demonstrate how a new product or service they are offering will provide greater value. Third, they can use their knowledge of how their market offerings specifically deliver value to craft persuasive value propositions. And fourth, they can use value models to provide evidence to customers of their accomplishments. Doing business based on value delivered gives companies the means to get an equitable return for their efforts. Once suppliers truly understand value, they will be able to realize the benefits of measuring and monitoring it for their customers.

  14. Valuing urban open space using the travel-cost method and the implications of measurement error.

    PubMed

    Hanauer, Merlin M; Reid, John

    2017-08-01

    Urbanization has placed pressure on open space within and adjacent to cities. In recent decades, a greater awareness has developed to the fact that individuals derive multiple benefits from urban open space. Given the location, there is often a high opportunity cost to preserving urban open space, thus it is important for both public and private stakeholders to justify such investments. The goals of this study are twofold. First, we use detailed surveys and precise, accessible, mapping methods to demonstrate how travel-cost methods can be applied to the valuation of urban open space. Second, we assess the degree to which typical methods of estimating travel times, and thus travel costs, introduce bias to the estimates of welfare. The site we study is Taylor Mountain Regional Park, a 1100-acre space located immediately adjacent to Santa Rosa, California, which is the largest city (∼170,000 population) in Sonoma County and lies 50 miles north of San Francisco. We estimate that the average per trip access value (consumer surplus) is $13.70. We also demonstrate that typical methods of measuring travel costs significantly understate these welfare measures. Our study provides policy-relevant results and highlights the sensitivity of urban open space travel-cost studies to bias stemming from travel-cost measurement error. Copyright © 2017 Elsevier Ltd. All rights reserved.

  15. ESR concept paper on value-based radiology.

    PubMed

    2017-10-01

    The European Society of Radiology (ESR) established a Working Group on Value-Based Imaging (VBI WG) in August 2016 in response to developments in European healthcare systems in general, and the trend within radiology to move from volume- to value-based practice in particular. The value-based healthcare (VBH) concept defines "value" as health outcomes achieved for patients relative to the costs of achieving them. Within this framework, value measurements start at the beginning of therapy; the whole diagnostic process is disregarded, and is considered only if it is the cause of errors or complications. Making the case for a new, multidisciplinary organisation of healthcare delivery centred on the patient, this paper establishes the diagnosis of disease as a first outcome in the interrelated activities of the healthcare chain. Metrics are proposed for measuring the quality of radiologists' diagnoses and the various ways in which radiologists provide value to patients, other medical specialists and healthcare systems at large. The ESR strongly believes value-based radiology (VBR) is a necessary complement to existing VBH concepts. The Society is determined to establish a holistic VBR programme to help European radiologists deal with changes in the evolution from volume- to value-based evaluation of radiological activities. Main Messages • Value-based healthcare defines value as patient's outcome over costs. • The VBH framework disregards the diagnosis as an outcome. • VBH considers diagnosis only if wrong or a cause of complications. • A correct diagnosis is the first outcome that matters to patients. • Metrics to measure radiologists' impacts on patient outcomes are key. • The value provided by radiology is multifaceted, going beyond exam volumes.

  16. Human biomonitoring reference values for some non-persistent chemicals in blood and urine derived from the Canadian Health Measures Survey 2009-2013.

    PubMed

    Khoury, Cheryl; Werry, Kate; Haines, Douglas; Walker, Mike; Malowany, Morie

    2018-05-01

    The Canadian Health Measures Survey collects nationally representative human biomonitoring data on a suite of chemicals and their metabolites, including many non-persistent chemicals. Data has been collected on non-persistent chemicals, including acrylamide, chlorophenols, environmental phenols and triclocarban, organophosphate insecticides, phthalates, polycyclic aromatic hydrocarbon, pyrethroid insecticides, and volatile organic compounds from 2009 to 2013. Using a systematic approach building on the reference interval concept proposed by the International Federation of Clinical Chemistry and Laboratory Medicine and the International Union of Pure and Applied Chemistry, we derive human biomonitoring reference values (RV 95 s) for these classes of non-persistent chemicals in blood and urine for the general Canadian population. RV 95 s were derived for biomarkers of non-persistent chemicals with widespread detection in Canadians (>66% detection rate). Samples with urinary creatinine levels outside the recommended range of 0.3-3.0 μg/L were excluded. Reference populations were constructed by applying smoking and fasting as exclusion criteria where appropriate. Age and sex were evaluated as possible partitioning criteria and separate RV 95 s were derived for sub-populations in cases where partitioning was deemed necessary. Reference values were derived for 40 biomarkers and represent the first set of RV 95 s for non-persistent chemicals in the general Canadian population. These values provide a measure of the upper margin of background exposure in the general population and can be compared against individual and population human biomonitoring data. RV 95 s can be used to by public health officials to identify individuals with high exposures, and by risk assessors and risk managers to identify atypical exposures or subpopulations with elevated exposures. Crown Copyright © 2018. Published by Elsevier GmbH. All rights reserved.

  17. Judging Surgical Research: How Should We Evaluate Performance and Measure Value?

    PubMed Central

    Souba, Wiley W.; Wilmore, Douglas W.

    2000-01-01

    Objective To establish criteria to evaluate performance in surgical research, and to suggest strategies to optimize research in the future. Summary Background Data Research is an integral component of the academic mission, focusing on important clinical problems, accounting for surgical advances, and providing training and mentoring for young surgeons. With constraints on healthcare resources, there is increasing pressure to generate clinical revenues at the expense of the time and effort devoted to surgical research. An approach that would assess the value of research would allow prioritization of projects. Further, alignment of high-priority research projects with clinical goals would optimize research gains and maximize the clinical enterprise. Methods The authors reviewed performance criteria applied to industrial research and modified these criteria to apply to surgical research. They reviewed several programs that align research objectives with clinical goals. Results Performance criteria were categorized along several dimensions: internal measures (quality, productivity, innovation, learning, and development), customer satisfaction, market share, and financial indices (cost and profitability). A “report card” was proposed to allow the assessment of research in an individual department or division. Conclusions The department’s business strategy can no longer be divorced from its research strategy. Alignment between research and clinical goals will maximize the department’s objectives but will create the need to modify existing hierarchical structures and reward systems. Such alignment appears to be the best way to ensure the success of surgical research in the future. PMID:10862192

  18. Personality Dominant Values in Graphic Design Students in Their Educational Practice

    ERIC Educational Resources Information Center

    Flores, René Pedroza

    2016-01-01

    The purpose of this article is to study the personality dominant values in Graphic Design students from the Autonomous University of the State of Mexico. A scale developed by Allport, Vernon and Lindsey called: "Study of values. A scale for the measuring of personality dominant interests" was used. The sample was applied to 124 students,…

  19. NASA/DOD Aerospace Knowledge Diffusion Research Project. Paper 48: Valuing information in an interactive environment

    NASA Technical Reports Server (NTRS)

    Brinberg, Herbert R.; Pinelli, Thomas E.; Barclay, Rebecca O.

    1995-01-01

    Consideration effort has been devoted over the past 30 years to developing methods and means of assessing the value of information. Two approaches - value in exchange and value in use - dominate; however, neither approach enjoys much practical application because validation schema for decision-making is missing. The approaches fail to measure objectively the real costs of acquiring information and the real benefits that information will yield. Moreover, these approaches collectively fail to provide economic justification to build and/or continue to support an information product or service. In addition, the impact of Cyberspace adds a new dimension to the problem. A new paradigm is required to make economic sense in this revolutionary information environment. In previous work, the authors explored the various approaches to measuring the value of information and concluded that, in large measure, these methods were unworkable concepts and constructs. Instead, they proposed several axioms for valuing information. Most particularly they concluded that the 'value of information cannot be measured in the absence of a specific task, objective, or goal.' This paper builds on those axioms and describes under which circumstances information can be measured in objective and actionable terms. This paper also proposes a methodology for undertaking such measures and validating the results.

  20. Biases associated with genotype and sex in prediction of fat-free lean mass and carcass value in hogs.

    PubMed

    Hicks, C; Schinckel, A P; Forrest, J C; Akridge, J T; Wagner, J R; Chen, W

    1998-09-01

    Carcass and live measurements of 165 market hogs that represented seven genotypes were used to investigate genotype and sex biases associated with the prediction of fat-free lean mass (FFLM) and carcass value. Carcass value was determined as the sum of the product of weight of individual cuts and their average unit prices adjusted for slaughter and processing costs. Independent variables used in the prediction equations included carcass measurements, such as optical probe, midline ruler, ribbed carcass measurements, and electromagnetic scanning (EMSCAN), and live animal ultrasonic scanning. The effect of including subpopulation mean values of independent variables in the prediction equations for FFLM and carcass value was also investigated. Genotype and sex biases were found in equations in which midline backfat, ribbed carcass, EMSCAN, and live ultrasonic scanning were used as single technology sets of measurements. The prediction equations generally undervalued genotypes with above-average carcass value. Biases were reduced when measurements of combined technologies and mean adjusted variables were used. The FFLM and carcass value of gilts were underestimated, and they were overestimated of barrows. Equations that combined OP and EMSCAN technologies were the most accurate and least biased for both FFLM and carcass value. Equations that included carcass weight and midline last-rib backfat thickness measurements were the least accurate and most biased. Genotype and sex biases must be considered when predicting FFLM and carcass value.

  1. 18 CFR 801.11 - Public values.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 18 Conservation of Power and Water Resources 2 2010-04-01 2010-04-01 false Public values. 801.11... POLICIES § 801.11 Public values. (a) The basin has many points of archeological and historic interest, and... value of these areas cannot be measured simply in economic terms and will strive to preserve and promote...

  2. 18 CFR 801.11 - Public values.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... value of these areas cannot be measured simply in economic terms and will strive to preserve and promote... 18 Conservation of Power and Water Resources 2 2011-04-01 2011-04-01 false Public values. 801.11... POLICIES § 801.11 Public values. (a) The basin has many points of archeological and historic interest, and...

  3. Use of Low-Value Pediatric Services Among the Commercially Insured

    PubMed Central

    Schwartz, Aaron L.; Volerman, Anna; Conti, Rena M.; Huang, Elbert S.

    2016-01-01

    BACKGROUND: Claims-based measures of “low-value” pediatric services could facilitate the implementation of interventions to reduce the provision of potentially harmful services to children. However, few such measures have been developed. METHODS: We developed claims-based measures of 20 services that typically do not improve child health according to evidence-based guidelines (eg, cough and cold medicines). Using these measures and claims from 4.4 million commercially insured US children in the 2014 Truven MarketScan Commercial Claims and Encounters database, we calculated the proportion of children who received at least 1 low-value pediatric service during the year, as well as total and out-of-pocket spending on these services. We report estimates based on "narrow" measures designed to only capture instances of service use that were low-value. To assess the sensitivity of results to measure specification, we also reported estimates based on "broad measures" designed to capture most instances of service use that were low-value. RESULTS: According to the narrow measures, 9.6% of children in our sample received at least 1 of the 20 low-value services during the year, resulting in $27.0 million in spending, of which $9.2 million was paid out-of-pocket (33.9%). According to the broad measures, 14.0% of children in our sample received at least 1 of the 20 low-value services during the year. CONCLUSIONS: According to a novel set of claims-based measures, at least 1 in 10 children in our sample received low-value pediatric services during 2014. Estimates of low-value pediatric service use may vary substantially with measure specification. PMID:27940698

  4. Phase-space representations of symmetric informationally complete positive-operator-valued-measure fiducial states

    NASA Astrophysics Data System (ADS)

    Saraceno, Marcos; Ermann, Leonardo; Cormick, Cecilia

    2017-03-01

    The problem of finding symmetric informationally complete positive-operator-valued-measures (SIC-POVMs) has been solved numerically for all dimensions d up to 67 [A. J. Scott and M. Grassl, J. Math. Phys. 51, 042203 (2010), 10.1063/1.3374022], but a general proof of existence is still lacking. For each dimension, it was shown that it is possible to find a SIC-POVM that is generated from a fiducial state upon application of the operators of the Heisenberg-Weyl group. We draw on the numerically determined fiducial states to study their phase-space features, as displayed by the characteristic function and the Wigner, Bargmann, and Husimi representations, adapted to a Hilbert space of finite dimension. We analyze the phase-space localization of fiducial states, and observe that the SIC-POVM condition is equivalent to a maximal delocalization property. Finally, we explore the consequences in phase space of the conjectured Zauner symmetry. In particular, we construct a Hermitian operator commuting with this symmetry that leads to a representation of fiducial states in terms of eigenfunctions with definite semiclassical features.

  5. "Value"ing Children Differently? Migrant Children in Education

    ERIC Educational Resources Information Center

    Devine, Dympna

    2013-01-01

    This paper considers dilemmas around "value" and the "valuing" of children and childhood(s) in schools. I argue that in neo-liberal contexts, processes of children's identity making become aligned with the idea of the corporate citizen--value and worth derived from the capacity to produce, excel, self-regulate as well as…

  6. Values in a Science of Social Work: Values-Informed Research and Research-Informed Values

    ERIC Educational Resources Information Center

    Longhofer, Jeffrey; Floersch, Jerry

    2014-01-01

    While social work must be evaluative in relation to its diverse areas of practice and research (i.e., values-informed research), the purpose of this article is to propose that values are within the scope of research and therefore research on practice should make values a legitimate object of investigation (i.e., research-informed values). In this…

  7. Computing pKa Values in Different Solvents by Electrostatic Transformation.

    PubMed

    Rossini, Emanuele; Netz, Roland R; Knapp, Ernst-Walter

    2016-07-12

    We introduce a method that requires only moderate computational effort to compute pKa values of small molecules in different solvents with an average accuracy of better than 0.7 pH units. With a known pKa value in one solvent, the electrostatic transform method computes the pKa value in any other solvent if the proton solvation energy is known in both considered solvents. To apply the electrostatic transform method to a molecule, the electrostatic solvation energies of the protonated and deprotonated molecular species are computed in the two considered solvents using a dielectric continuum to describe the solvent. This is demonstrated for 30 molecules belonging to 10 different molecular families by considering 77 measured pKa values in 4 different solvents: water, acetonitrile, dimethyl sulfoxide, and methanol. The electrostatic transform method can be applied to any other solvent if the proton solvation energy is known. It is exclusively based on physicochemical principles, not using any empirical fetch factors or explicit solvent molecules, to obtain agreement with measured pKa values and is therefore ready to be generalized to other solute molecules and solvents. From the computed pKa values, we obtained relative proton solvation energies, which agree very well with the proton solvation energies computed recently by ab initio methods, and used these energies in the present study.

  8. Nursing values in China: the expectations of registered nurses.

    PubMed

    Pang, Dong; Senaratana, Wilawan; Kunaviktikul, Wipada; Klunklin, Areewan; McElmurry, Beverly J

    2009-09-01

    Abstract The purpose of this study was to identify the essential professional values of Chinese nurses and their manifestations in the current health-care environment. Data were collected from 29 nurse experts by semi-structured individual interviews or focus groups in Beijing and Shanghai, China. Thematic analysis was used to analyze the data. Seven themes were identified: altruism, caring, trustworthiness, dignity, responsibility for the development of the profession, autonomy, and justice. On the whole, these values were in accordance with the codes of the International Council of Nurses and the Chinese Nursing Association. Additionally, culture and socioeconomic trends were found to have an influence on nurses' understanding and explanation of professional values. The findings of this study provided insight into Chinese nurses' professional values and might contribute to the future development of a culturally sensitive scale to measure nursing values in China.

  9. Distributions of p-values smaller than .05 in psychology: what is going on?

    PubMed Central

    van Aert, Robbie C.M.; Nuijten, Michèle B.; Wicherts, Jelte M.; van Assen, Marcel A.L.M.

    2016-01-01

    Previous studies provided mixed findings on pecularities in p-value distributions in psychology. This paper examined 258,050 test results across 30,710 articles from eight high impact journals to investigate the existence of a peculiar prevalence of p-values just below .05 (i.e., a bump) in the psychological literature, and a potential increase thereof over time. We indeed found evidence for a bump just below .05 in the distribution of exactly reported p-values in the journals Developmental Psychology, Journal of Applied Psychology, and Journal of Personality and Social Psychology, but the bump did not increase over the years and disappeared when using recalculated p-values. We found clear and direct evidence for the QRP “incorrect rounding of p-value” (John, Loewenstein & Prelec, 2012) in all psychology journals. Finally, we also investigated monotonic excess of p-values, an effect of certain QRPs that has been neglected in previous research, and developed two measures to detect this by modeling the distributions of statistically significant p-values. Using simulations and applying the two measures to the retrieved test results, we argue that, although one of the measures suggests the use of QRPs in psychology, it is difficult to draw general conclusions concerning QRPs based on modeling of p-value distributions. PMID:27077017

  10. Measuring risk-adjusted value using Medicare and ACS-NSQIP: is high-quality, low-cost surgical care achievable everywhere?

    PubMed

    Lawson, Elise H; Zingmond, David S; Stey, Anne M; Hall, Bruce L; Ko, Clifford Y

    2014-10-01

    To evaluate the relationship between risk-adjusted cost and quality for colectomy procedures and to identify characteristics of "high value" hospitals (high quality, low cost). Policymakers are currently focused on rewarding high-value health care. Hospitals will increasingly be held accountable for both quality and cost. Records (2005-2008) for all patients undergoing colectomy procedures in the American College of Surgeons National Surgical Quality Improvement Program (ACS-NSQIP) were linked to Medicare inpatient claims. Cost was derived from hospital payments by Medicare. Quality was derived from the occurrence of 30-day postoperative major complications and/or death as recorded in ACS-NSQIP. Risk-adjusted cost and quality metrics were developed using hierarchical multivariable modeling, consistent with a National Quality Forum-endorsed colectomy measure. The study population included 14,745 colectomy patients in 169 hospitals. Average hospitalization cost was $21,350 (SD $20,773, median $16,092, interquartile range $14,341-$24,598). Thirty-four percent of patients had a postoperative complication and/or death. Higher hospital quality was significantly correlated with lower cost (correlation coefficient 0.38, P < 0.001). Among hospitals classified as high quality, 52% were found to be low cost (representing highest value hospitals) whereas 14% were high cost (P = 0.001). Forty-one percent of low-quality hospitals were high cost. Highest "value" hospitals represented a mix of teaching/nonteaching affiliation, small/large bed sizes, and regional locations. Using national ACS-NSQIP and Medicare data, this study reports an association between higher quality and lower cost surgical care. These results suggest that high-value surgical care is being delivered in a wide spectrum of hospitals and hospital types.

  11. [Relation between personality traits and personal values in cocaine-dependent patients].

    PubMed

    Saiz, Jesús; Álvaro, José Luis; Martínez, Isabel

    2011-01-01

    To describe the relationship between personal values and personality traits in cocaine-using patients and analyze their specificity in the explanation of different types of constructs. A study was carried out to explore the association between these variables in a group of 230 patients receiving treatment for cocaine dependence. The Portrait Values Questionnaire was used for measuring personal values, while the Big-Five Factors Questionnaire was used to measure personality traits. In addition, we explored the relationship of values and traits with the variables "degree of satisfaction with life" (life satisfaction) and "belonging to a religious association" (religiosity). A significant association was found between personal values and personality traits. At the same time, their conceptual and empirical differences were revealed, as it was demonstrated that personal values better explain "belonging to a religious association", whilst personality traits better explain "degree of satisfaction with life". Thus, it was found that personal values better explain behaviours that depend on greater cognitive control, while personality traits would have more influence on tendencies and behaviours that are subject to lower cognitive control levels. Considering the relationship between the two constructs, and given that cocaine use is associated with both high and low cognitive control, in explanations of cocaine use it would be appropriate to take into account the explanatory contribution of personal values and personality traits in a complementary way.

  12. Depletions in winter total ozone values over southern England

    NASA Technical Reports Server (NTRS)

    Lapworth, A.

    1994-01-01

    A study has been made of the recently re-evaluated time series of daily total ozone values for the period 1979 to 1992 for southern England. The series consists of measurements made at two stations, Bracknell and Camborne. The series shows a steady decline in ozone values in the spring months over the period, and this is consistent with data from an earlier decade that has been published but not re-evaluated. Of exceptional note is the monthly mean for January 1992 which was very significantly reduced from the normal value, and was the lowest so far measured for this month. This winter was also noteworthy for a prolonged period during which a blocking anticyclone dominated the region, and the possibility existed that this was related to the ozone anomaly. It was possible to determine whether the origin of the low ozone value lay in ascending stratospheric motions. A linear regression analysis of ozone value deviation against 100hPa temperature deviations was used to reduce ozone values to those expected in the absence of high pressure. The assumption was made that the normal regression relation was not affected by atmospheric anomalies during the winter. This showed that vertical motions in the stratosphere only accounted for part of the ozone anomaly and that the main cause of the ozone deficit lay either in a reduced stratospheric circulation to which the anticyclone may be related or in chemical effects in the reduced stratospheric temperatures above the high pressure area. A study of the ozone time series adjusted to remove variations correlated with meteorological quantities, showed that during the period since 1979, one other winter, that of 1982/3, showed a similar although less well defined deficit in total ozone values.

  13. Three common misuses of P values

    PubMed Central

    Kim, Jeehyoung; Bang, Heejung

    2016-01-01

    “Significance” has a specific meaning in science, especially in statistics. The p-value as a measure of statistical significance (evidence against a null hypothesis) has long been used in statistical inference and has served as a key player in science and research. Despite its clear mathematical definition and original purpose, and being just one of the many statistical measures/criteria, its role has been over-emphasized along with hypothesis testing. Observing and reflecting on this practice, some journals have attempted to ban reporting of p-values, and the American Statistical Association (for the first time in its 177 year old history) released a statement on p-values in 2016. In this article, we intend to review the correct definition of the p-value as well as its common misuses, in the hope that our article is useful to clinicians and researchers. PMID:27695640

  14. An empirical assessment of generational differences in basic human values.

    PubMed

    Lyons, Sean T; Duxbury, Linda; Higgins, Christopher

    2007-10-01

    This study assessed generational differences in human values as measured by the Schwartz Value Survey. It was proposed that the two most recent generations, Millennials and Generation Xers, would value Self-enhancement and Openness to Change more than the two older generations, Baby Boomers and Matures, while the two older generations would value Self-transcendence and Conservation more. The hypotheses were tested with a combined sample of Canadian knowledge workers and undergraduate business students (N = 1,194). Two hypotheses were largely supported, although an unexpectedly large difference was observed between Millennials and Generation Xers with respect to Openness to Change and Self-enhancement. The findings suggest that generation is a useful variable in examining differences in social values.

  15. Low-Value Service Use in Provider Organizations.

    PubMed

    Schwartz, Aaron L; Zaslavsky, Alan M; Landon, Bruce E; Chernew, Michael E; McWilliams, J Michael

    2018-02-01

    To assess whether provider organizations exhibit distinct profiles of low-value service provision. 2007-2011 Medicare fee-for-service claims and enrollment data. Use of 31 services that provide minimal clinical benefit was measured for 4,039,733 beneficiaries served by 3,137 provider organizations. Variation across organizations, persistence within organizations over time, and correlations in use of different types of low-value services within organizations were estimated via multilevel modeling, with adjustment for beneficiary sociodemographic and clinical characteristics. Organizations provided 45.6 low-value services per 100 beneficiaries on average, with considerable variation across organizations (90th/10th percentile ratio, 1.78; 95 percent CI, 1.72-1.84), including substantial between-organization variation within hospital referral regions (90th/10th percentile ratio, 1.66; 95 percent CI, 1.60-1.71). Low-value service use within organizations was highly correlated over time (r, 0.98; 95 percent CI, 0.97-0.99) and positively correlated between 13 of 15 pairs of service categories (average r, 0.26; 95 percent CI, 0.24-0.28), with the greatest correlation between low-value imaging and low-value cardiovascular testing and procedures (r, 0.54). Use of low-value services in provider organizations exhibited substantial variation, high persistence, and modest consistency across service types. These findings are consistent with organizations shaping the practice patterns of affiliated physicians. © Health Research and Educational Trust.

  16. Validation of the Long- and Short-Form of the Ethical Values Assessment (EVA): A Questionnaire Measuring the Three Ethics Approach to Moral Psychology

    ERIC Educational Resources Information Center

    Padilla-Walker, Laura Maria; Jensen, Lene Arnett

    2016-01-01

    Moral psychology has been moving toward consideration of multiple kinds of moral concepts and values, such as the Ethics of Autonomy, Community, and Divinity. While these three ethics have commonly been measured qualitatively, the current study sought to validate the long and short forms of the Ethical Values Assessment (EVA), which is a…

  17. Reference Values of Total Lean Mass, Appendicular Lean Mass, and Fat Mass Measured with Dual-Energy X-ray Absorptiometry in a Healthy Mexican Population.

    PubMed

    Clark, Patricia; Denova-Gutiérrez, Edgar; Ambrosi, Regina; Szulc, Pawel; Rivas-Ruiz, Rodolfo; Salmerón, Jorge

    2016-11-01

    The aim of this study was to develop age- and gender-specific reference values of total lean body mass (LBM), appendicular lean body mass (ALBM), and fat mass (FM) by dual-energy X-ray absorptiometry (DXA) data in a healthy Mexican population. A cross-sectional analysis was conducted on 9518 healthy subjects 7-89 years of age participating in the baseline measurement of the Health Workers Cohort Study. Using DXA, LBM, ALBM, and FM were measured. Using these data, LBM index (LBMI), ALBM index (ALBMI), and fat mass index (FMI) were calculated. LMI, ALMI, and FMI were calculated as the LBM, ALBM, and FM kg divided by the height in meters squared. Males and females were analyzed separately; sex-specific means and standard deviations for LBM, ALBM, FM, LBMI, ALBMI, and FMI were calculated. A total of 2829 males and 6694 females were included in the final analysis. Strong sex gaps were observed after 12 years in LBM, ALBM, LBMI, and ALBMI (P < 0.01). LBM and ALBM values continue to increase for males up to age 20; females plateaued approximately after age 15. Significant sex differences were also observed for FM and FMI. Significant sex- and age-related differences exist in LBM, ALBM, and FM in the Mexican population. In addition, given the null data available in this area, these reference values may be useful in the evaluation of a variety of childhood and adult abnormalities involving lean body mass deficits, mainly in the assessment of muscle wasting, with important medical and epidemiological uses.

  18. Measuring salient food attitudes and food-related values. An elaborated, conflicting and interdependent system.

    PubMed

    Hauser, Mirjam; Jonas, Klaus; Riemann, Rainer

    2011-10-01

    Consumer food choice behaviour in post-industrial countries is complex and influenced by a multitude of interacting variables. This study looked at the antecedents of behaviour and examined salient food-related values and attitudes. To discover personal meanings and patterns of everyday food choices across different situations we used a qualitative approach in the form of repertory grid interviews. An analysis of the personal constructs elicited from a representative sample of 100 Swiss consumers revealed elaborated value systems. The food-related values can be summarised as: authenticity/naturalness, conviviality, health, quality/indulgence, convenience, and price. The salience of these values and their negatively evaluated counterparts differed for various social eating situations and product categories. Consumers' personal values also differed significantly from their perception of current trends in eating culture. In every-day food choices interdependent food-related values compete and are thus a possible cause of ambivalence and conflicts. The findings offer explanations of discrepancies between values/attitudes and behaviour that may be due to situational constraints and habits. Implications for companies include the need for strategic realignment to regain consumers' trust by providing comprehensive value-congruent food solutions that also consider health and ethical criteria. Copyright © 2011 Elsevier Ltd. All rights reserved.

  19. Added Value of Patient-Reported Outcome Measures in Stroke Clinical Practice.

    PubMed

    Katzan, Irene L; Thompson, Nicolas R; Lapin, Brittany; Uchino, Ken

    2017-07-21

    There is uncertainty regarding the clinical utility of the data obtained from patient-reported outcome measures (PROMs) for patient care. We evaluated the incremental information obtained by PROMs compared to the clinician-reported modified Rankin Scale (mRS). This was an observational study of 3283 ischemic stroke patients seen in a cerebrovascular clinic from September 14, 2012 to June 16, 2015 who completed the routinely collected PROMs: Stroke Impact Scale-16 (SIS-16), EQ-5D, Patient Health Questionnaire-9, PROMIS Physical Function, and PROMIS fatigue. The amount of variation in the PROMs explained by mRS was determined using r 2 after adjustment for age and level of stroke impairment. The proportion with meaningful change was calculated for patients with ≥2 visits. Concordance with change in the other scales and the ability to discriminate changes in health state as measured by c-statistic was evaluated for mRS versus SIS-16. Correlation between PROMs and mRS was highest for SIS-16 ( r =-0.64, P <0.01). The r 2 ranged from 0.11 (PROMIS fatigue) to 0.56 (SIS-16). Change in scores occurred in 51% with mRS and 35% with SIS-16. There was lower agreement and less ability to discriminate change in mRS than in SIS-16 with change in the other measures. PROMs provide additional valuable information compared to the mRS alone in stroke patients seen in the ambulatory setting. SIS-16 may have a better ability to identify change than mRS in health status of relevance to the patient. PROMs may be a useful addition to mRS in the assessment of health status in clinical practice. © 2017 The Authors. Published on behalf of the American Heart Association, Inc., by Wiley.

  20. Cosmic ray particles with different LET values under various thicknesses of shielding in low altitude orbits: calculations and Cosmos-2044 measurements

    NASA Technical Reports Server (NTRS)

    Marenny, A. M.; Nymmik, R. A.; Suslov, A. A.; Benton, E. V.; Frank, A. L.; Benton, E. R.

    1992-01-01

    Fluxes of cosmic ray particles with different LET values were measured on board the Cosmos-2044 biosatellite under various thicknesses of shielding by stacks of CR-39 and nitrocellulose plastic nuclear track detectors (mounted outside the satellite). The component composition of the particles detected under shieldings of 0.1-2.5 g cm-2 is verified by comparing experimental data with the results of model simulations of the fluxes of galactic cosmic ray particles and of radiation belt protons.

  1. Measurement of the infrared optical constants for spectral modeling: n and k values for (NH4)2SO4 via single-angle reflectance and ellipsometric methods

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Blake, Thomas A.; Brauer, Carolyn S.; Kelly-Gorham, Molly Rose K.

    The optical constants n and k can be used to model infrared spectra, including refraction, absorption, reflectance, and emissivity, but obtaining reliable values for solid materials (pure or otherwise) presents a challenge: In the past, the best results for n and k have been obtained from bulk, homogeneous materials, free of defects. That is, materials where the Fresnel equations are operant since there is no light scattering. Since it is often not possible to obtain a pure macroscopic (crystalline) material, it may be possible to press the material into a (uniform, void-free) disk. We have recently been able to domore » this with ammonium sulfate powder and then measured the n & k values via two independent methods: 1) Ellipsometry - which measures the changes in amplitude and phase of light reflected from the material of interest as a function of wavelength and angle of incidence, and 2) Single angle specular reflectance with an FT spectrometer using a specular reflectance device within an FT instrument which measures the change in amplitude of light reflected from the material of interest as a function of wavelength and angle of incidence over a wide wavelength range. The quality of the derived n & k values was tested by generating the reflectance spectra of the pellet and comparing to the calculated to measured reflectance spectra of the pure material which has been previously published. The comparison to literature values showed good accuracy and good agreement, indicating promise to measure other materials by such methods.« less

  2. B (e 2 ;21+→01+) value in 90Kr

    NASA Astrophysics Data System (ADS)

    Régis, J.-M.; Jolie, J.; Saed-Samii, N.; Warr, N.; Pfeiffer, M.; Blanc, A.; Jentschel, M.; Köster, U.; Mutti, P.; Soldner, T.; Simpson, G. S.; Drouet, F.; Vancraeyenest, A.; de France, G.; Clément, E.; Stezowski, O.; Ur, C. A.; Urban, W.; Regan, P. H.; Podolyák, Zs.; Larijani, C.; Townsley, C.; Carroll, R.; Wilson, E.; Fraile, L. M.; Mach, H.; Paziy, V.; Olaizola, B.; Vedia, V.; Bruce, A. M.; Roberts, O. J.; Smith, J. F.; Kröll, T.; Hartig, A.-L.; Ignatov, A.; Ilieva, S.; Thürauf, M.; Lalkovski, S.; Ivanova, D.; Kisyov, S.; Korten, W.; Salsac, M.-D.; Zielińska, M.; Mǎrginean, N.; Ghitǎ, D. G.; Licǎ, R.; Petrache, C. M.; Astier, A.; Leguillon, R.

    2014-12-01

    A smooth onset of collectivity in 88 ,92 ,94 ,96Kr has been determined from reported B (E 2 ;21+→01+) and E (21+) values. This is in contrast to the sudden onset in even-even Zr, Mo, and Sr isotopes. Our objective was to complete the systematics by determining the B (E 2 ;21+→01+) value in 90Kr, which was produced by cold-neutron-induced fission of 235U . The lifetime of the 21+ state in 90Kr was measured via the electronic γ -γ timing technique using the EXILL and FATIMA spectrometers. Based on the measured mean lifetime of τ = 15(10) ps, the B (E 2 ;21+→01+) value of 13 -5+26 W.u. in 90Kr is determined for the first time and the smooth onset of deformation in the even-even Kr isotopes beyond neutron number N =50 is confirmed.

  3. [Digital blood flow measurement by venous occlusion plethysmography in Raynaud's phenomenon. Value of the rewarming test].

    PubMed

    Cristol, R; Debray, J

    1986-01-01

    The fingertip blood flow measured by mercury strain gauge plethysmography with venous occlusion, at 22 degrees C room temperature, had significantly lower mean values in 190 patients with Raynaud's phenomenon (55 men aged 49 yrs +/- 16, 135 women aged 48 yrs +/- 16) than in 40 age and sex matched controls: 18 ml/100 ml/minute +/- 14.6 versus 35 ml/100 ml/minute +/- 15 at level p less than 0.01. The mean fingertip blood flow was significantly lower (p less than 0.01) in 31 cases of scleroderma and 32 cases of pulpar necrosis (respectively 13 ml +/- 13 and 11 ml +/- 8) than in 55 cases of primary Raynaud's disease (no detectable etiology and normal capillaroscopy 5 years after onset) or in 34 cases of mild Raynaud's phenomenon (respectively 21.6 +/- 16 and 24.4 +/- 18). A warming test (both hands in water at 45 degrees C during 3 minutes) was performed in 50 cases with low basal fingertip blood flow. It induced a "normalized" flow in 22 cases (mostly primary or mild Raynaud), a partly improved flow in 20 cases (mostly secondary Raynaud) and no improvement in 8 cases (scleroderma). The warming test appears to be clinically useful to assess the vasospasm and the vasodilating capabilities.

  4. Recruiting for values in healthcare: a preliminary review of the evidence.

    PubMed

    Patterson, Fiona; Prescott-Clements, Linda; Zibarras, Lara; Edwards, Helena; Kerrin, Maire; Cousans, Fran

    2016-10-01

    Displaying compassion, benevolence and respect, and preserving the dignity of patients are important for any healthcare professional to ensure the provision of high quality care and patient outcomes. This paper presents a structured search and thematic review of the research evidence relating to values-based recruitment within healthcare. Several different databases, journals and government reports were searched to retrieve studies relating to values-based recruitment published between 1998 and 2013, both in healthcare settings and other occupational contexts. There is limited published research related to values-based recruitment directly, so the available theoretical context of values is explored alongside an analysis of the impact of value congruence. The implications for the design of selection methods to measure values is explored beyond the scope of the initial literature search. Research suggests some selection methods may be appropriate for values-based recruitment, such as situational judgment tests (SJTs), structured interviews and multiple-mini interviews (MMIs). Personality tests were also identified as having the potential to compliment other methods (e.g. structured interviews), as part of a values-based recruitment agenda. Methods including personal statements, references and unstructured/'traditional' interviews were identified as inappropriate for values-based recruitment. Practical implications are discussed in the context of values-based recruitment in the healthcare context. Theoretical implications of our findings imply that prosocial implicit trait policies, which could be measured by selection tools such as SJTs and MMIs, may be linked to individuals' values via the behaviours individuals consider to be effective in given situations. Further research is required to state this conclusively however, and methods for values-based recruitment represent an exciting and relatively unchartered territory for further research.

  5. Validation of value of actual micromotion as a direct measure of implant micromobility after healing (secondary implant stability). An in vivo histologic and biomechanical study.

    PubMed

    Trisi, Paolo; Berardini, Marco; Falco, Antonello; Podaliri Vulpiani, Michele

    2016-11-01

    The osseointegration process replaces the surgically damaged bone with newly formed bone in contact to the implant surface. This involves some loss of primary stability, which will continue until new bone is formed providing a new stability, known as "secondary stability." A direct measurement of secondary implant stability appears fundamental to determine the period and modalities for implant loading. The aim of this study was to validate the measurement of the implant micromotion to test secondary implant stability. Twenty-four 3.8 × 11.5 mm implants (Dynamix, Cortex, Shlomi, Israel) were inserted in sheep iliac crests. The animals were sacrificed after 2 months, and the freshly retrieved bone blocks were immediately fixed on a customized device to calculate the value of actual micromotion (VAM) according to a previously described technique. Implant stability quotient (ISQ) values, reverse torque value (RTV), %bone-to-implant contact (%BIC), bone volume percentage (%BV) and crestal bone loss (CBL) were also calculated for each implant. Statistical correlations between VAM and the other parameters were calculated. Data correlation analysis between the examined parameters showed that VAM significantly correlates (P < 0.05) to RTV, %BIC, ISQ and CBL. As VAM showed to be statistical correlated to the other parameters of osseointegration, it may be used to clinically check the amount of implant osseointegration, secondary stability and CBL. Future studies are needed to confirm these results moreover. An instrument to measure VAM in the oral cavity still needs to be developed. © 2016 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  6. Remote measurement of water color in coastal waters. [spectral radiance data used to obtain quantitative values for chlorophyll and turbidity

    NASA Technical Reports Server (NTRS)

    Weldon, J. W.

    1973-01-01

    An investigation was conducted to develop procedure to obtain quantitative values for chlorophyll and turbidity in coastal waters by observing the changes in spectral radiance of the backscattered spectrum. The technique under consideration consists of Examining Exotech model 20-D spectral radiometer data and determining which radiance ratios best correlated with chlorophyll and turbidity measurements as obtained from analyses of water samples and sechi visibility readings. Preliminary results indicate that there is a correlation between backscattered light and chlorophyll concentration and secchi visibility. The tests were conducted with the spectrometer mounted in a light aircraft over the Mississippi Sound at altitudes of 2.5K, 2.8K and 10K feet.

  7. Using the Principles of F.A.I.R Data to Improve the Measure of Value of Big Data and Big Data Repositories

    NASA Astrophysics Data System (ADS)

    Richards, C. J.; Wyborn, L. A.; Evans, B. J. K.; Wang, J.; Druken, K. A.; Smillie, J.; Pringle, S.

    2017-12-01

    In a data-intensive world, finding the right data can be time-consuming and, when found, may involve compromises on quality and often considerable extra effort to wrangle it into shape. This is particularly true as users are exploring new and innovative ways of working with data from different sources and scientific domains. It is recognised that the effort and specialist knowledge required to transform datasets to meet these requirements goes beyond the reasonable remit of a single research project or research community. Instead, Government investments in national collaborations like the Australian National University's National Computational Infrastructure (NCI), provide a sustainable way to bring together and transform disparate data collections from a range of disciplines in ways which enable new and innovative analysis and use. With these goals in mind, the NCI established a Data Quality Strategy (DQS) for managing 10PB of reference data collections with a particular focus on improving data use and reuse across scientific domains, making the data suitable for use in a high-end computational and data-intensive environment, and supporting programmatic access for a range of applications. Evaluating how effectively we're achivieving these goals and maintaining ongoing funding requires demonstration of the value and impact of these data collections. Standard approaches to measuring data value involve basic measures of `data usage' or make an attempt to track data to `research outcomes'. While useful, these measures fail to capture the value of the level of curation or quality assurance in making the data available. To fill this gap, NCI has developed a 3-tiered approach to measuring the return on investment which broadens the concept of value to include improvements in access to and use of the data. Key to this approach was integrating the guiding principles of the Force 11 community's F.A.I.R data into the DQS because it provides a community-driven standards

  8. Shuttle swimming test in young water polo players: reliability, responsiveness and age-related value.

    PubMed

    Melchiorri, Giovanni; Viero, Valerio; Triossi, Tamara; Padua, Elvira; Bonifazi, Marco

    2017-11-01

    This study investigated the applicability of a sport-specific test, the Shuttle Swim Test, in young water polo players to measure RSA. The aims were: to assess the reliability and to measure the responsiveness of the SST in young water polo athletes, and to provide age-related values of SST. Three hundred thirty-three elite athletes (18.3±5.1 years) were involved in the study. Of these, 99 were young people under 13 (13.1±0.5 years) who also underwent measurements for reliability and responsiveness of the SST The following six measures was used to assess anthropometric characteristics of the sample: height, weight, chest circumference, hip circumference, waist circumference, and arm span. Two performance measures were performed on dry land: push up and chin up. Reliability and responsiveness were measured by comparing the average speed of two trials: SST1 was 1.48±0.13 m·s-1 and SST2 1.47±.12 m·s-1. The SST showed good reliability in younger athletes (r=0.96). The Minimal Detectable Change is 0.06 m·s-1 (6 seconds of the total time) which corresponds to 3.6% of the average value measured, confirming the good responsiveness of the test. Coaches and researchers can use this value in the interpretation of the SST test results: changes below these values could be related to a measurement error. The various age-related values reported may help technicians to better interpret the performance of their athletes during competition.

  9. Measuring interdependence in ambulatory care.

    PubMed

    Katerndahl, David; Wood, Robert; Jaen, Carlos R

    2017-04-01

    Complex systems differ from complicated systems in that they are nonlinear, unpredictable and lacking clear cause-and-effect relationships, largely due to the interdependence of their components (effects of interconnectedness on system behaviour and consequences). The purpose of this study was to demonstrate the potential for network density to serve as a measure of interdependence, assess its concurrent validity and test whether the use of valued or binary ties yields better results. This secondary analysis used the 2010 National Ambulatory Care Medical Survey to assess interdependence of 'top 20' diagnoses seen and medications prescribed for 14 specialties. The degree of interdependence was measured as the level of association between diagnoses and drug interactions among medications. Both valued and binary network densities were computed for each specialty. To assess concurrent validity, these measures were correlated with previously-derived valid measures of complexity of care using the same database, adjusting for diagnosis and medication diversity. Partial correlations between diagnosis density, and both diagnosis and total input complexity, were significant, as were those between medication density and both medication and total output complexity; for both diagnosis and medication densities, adjusted correlations were higher for binary rather than valued densities. This study demonstrated the feasibility and validity of using network density as a measure of interdependence. When adjusted for measure diversity, density-complexity correlations were significant and higher for binary than valued density. This approach complements other methods of estimating complexity of care and may be applicable to unique settings. © 2015 John Wiley & Sons, Ltd.

  10. Segmentation of culturally diverse visitors' values in forest recreation management

    Treesearch

    C. Li; H.C. Zinn; G.E. Chick; J.D. Absher; A.R. Graefe; Y. Hsu

    2007-01-01

    The purpose of this study was to examine the potential utility of HOFSTEDE’s measure of cultural values (1980) for group segmentation in an ethnically diverse population in a forest recreation context, and to validate the values segmentation, if any, via socio-demographic and service quality related variables. In 2002, the visitors to the Angeles National Forest (ANF)...

  11. The ICER Value Framework: Integrating Cost Effectiveness and Affordability in the Assessment of Health Care Value.

    PubMed

    Pearson, Steven D

    2018-03-01

    What should be the relationship between the concepts of cost effectiveness and affordability in value assessments for health care interventions? This question has received greater attention in recent years given increasing financial pressures on health systems, leading to different views on how assessment reports and decision-making processes can provide the best structure for considering both elements. In the United States, the advent of explicit value frameworks to guide drug assessments has also focused attention on this issue, driven in part by the prominent inclusion of affordability within the value framework used to guide reports from the Institute for Clinical and Economic Review. After providing a formal definition of affordability for health care systems, this article argues that, even after using empirical estimates of true health system opportunity cost, cost-effectiveness thresholds cannot by themselves be set in a way that subsumes questions about short-term affordability. The article then presents an analysis of different approaches to integrating cost effectiveness and budget impact assessments within information to guide decision making. The evolution and experience with the Institute for Clinical and Economic Review value framework are highlighted, providing lessons learned and guiding principles for future efforts to bring measures of affordability within the scope of value assessment. Copyright © 2018 International Society for Pharmacoeconomics and Outcomes Research (ISPOR). Published by Elsevier Inc. All rights reserved.

  12. Comparison of Low-Value Care in Medicaid vs Commercially Insured Populations.

    PubMed

    Charlesworth, Christina J; Meath, Thomas H A; Schwartz, Aaron L; McConnell, K John

    2016-07-01

    Reducing unnecessary tests and treatments is a potentially promising approach for improving the value of health care. However, relatively little is known about whether insurance type or local practice patterns are associated with delivery of low-value care. To compare low-value care in the Medicaid and commercially insured populations, test whether provision of low-value care is associated with insurance type, and assess whether local practice patterns are associated with the provision of low-value care. This cross-sectional study of claims data from the Oregon Division of Medical Assistance Programs and the Oregon All-Payer All-Claims database included Medicaid and commercially insured adults aged 18 to 64 years. The study period was January 1, 2013, through December 31, 2013. Low-value care was assessed using 16 claims-based measures. Logistic regression was used to test the association between Medicaid vs commercial insurance coverage and low-value care and the association between Medicaid and commercial low-value care rates within primary care service areas (PCSAs). This study included 286 769 Medicaid and 1 376 308 commercial enrollees in 2013. Medicaid enrollees were younger (167 847 [58.5%] of Medicaid enrollees were aged 18-34 years vs 505 628 [36.7%] of those with commercial insurance) but generally had worse health status compared with those with commercial insurance. Medicaid enrollees were also more likely to be female (180 363 [62.9%] vs 702 165 [51.0%]) and live in a rural area (120 232 [41.9%] vs 389 964 [28.3%]). A total of 10 304 of 69 338 qualifying Medicaid patients (14.9%; 95% CI, 14.6%-15.1%) received at least 1 low-value service during 2013; the corresponding rate for commercially insured patients was 35 739 of 314 023 (11.4%; 95% CI, 11.3%-11.5%). No consistent association was found between insurance type and low-value care. Compared with commercial patients, Medicaid patients were more likely to receive low-value care for 10 measures

  13. The Value of Medicines: A Crucial but Vague Concept.

    PubMed

    Antoñanzas, Fernando; Terkola, Robert; Postma, Maarten

    2016-12-01

    Health Technology Assessment is increasingly used to evaluate the value of healthcare products and to prioritize resources; however, defining exactly what value is and how it should be measured remains a challenge. In this article, we report the results of a literature review, focusing on nine European countries, with the aim of investigating how value is defined from the perspective of different stakeholders, how definitions of value are used, and how value is incorporated into decision making. Only three articles were identified that presented definitions of value, and there was no single shared definition of value in healthcare, which appears to be a highly subjective concept. The majority of the countries investigated combine clinical assessment with economic evaluation to make reimbursement recommendations; the quality-adjusted life-year is the most commonly used measure of value but does not capture broader aspects of value that may be important to patients and healthcare systems. We describe the use of value-based pricing and multi-criteria decision analysis, two approaches to the incorporation of broader aspects of value into decision making. Overall, we have identified considerable variation in how a product's value is defined by different stakeholders. Although a universal understanding of value in healthcare is important, it is clear that current definitions are insufficient, potentially leading to inconsistent reimbursement decisions. Ultimately, the establishment of clearer policies for defining and measuring value in healthcare is needed, and is likely to lead to improvements in the consistency of decision making.

  14. Cosmic ray particles with different LET values under various thicknesses of shielding in low altitude orbits: Calculations and Cosmos-2044 measurements

    NASA Technical Reports Server (NTRS)

    Benton, E. V.; Frank, A. L.; Benton, E. R.; Marenny, A. M.; Nymmik, R. A.; Suslov, A. A.

    1995-01-01

    Fluxes of cosmic ray particles with different LET values were measured on board the COSMOS-2044 biosatellite under various thicknesses of shielding by stacks of CR-39 and nitrocellulose plastic nuclear track detectors (mounted outside the satellite). The component composition of the particles detected under shieldings of 0.1-2.5 g cm(exp -2) is verified by comparing experimental data with the results of model simulations of the fluxes of galactic cosmic ray particles and of radiation belt protons.

  15. Automated simultaneous measurement of the δ(13) C and δ(2) H values of methane and the δ(13) C and δ(18) O values of carbon dioxide in flask air samples using a new multi cryo-trap/gas chromatography/isotope ratio mass spectrometry system.

    PubMed

    Brand, Willi A; Rothe, Michael; Sperlich, Peter; Strube, Martin; Wendeberg, Magnus

    2016-07-15

    The isotopic composition of greenhouse gases helps to constrain global budgets and to study sink and source processes. We present a new system for high-precision stable isotope measurements of carbon, hydrogen and oxygen in atmospheric methane and carbon dioxide. The design is intended for analyzing flask air samples from existing sampling programs without the need for extra sample air for methane analysis. CO2 and CH4 isotopes are measured simultaneously using two isotope ratio mass spectrometers, one for the analysis of δ(13) C and δ(18) O values and the second one for δ(2) H values. The inlet carousel delivers air from 16 sample positions (glass flasks 1-5 L and high-pressure cylinders). Three 10-port valves take aliquots from the sample stream. CH4 from 100-mL air aliquots is preconcentrated in 0.8-mL sample loops using a new cryo-trap system. A precisely calibrated working reference air is used in parallel with the sample according to the Principle of Identical Treatment. It takes about 36 hours for a fully calibrated analysis of a complete carousel including extractions of four working reference and one quality control reference air. Long-term precision values, as obtained from the quality control reference gas since 2012, account for 0.04 ‰ (δ(13) C values of CO2 ), 0.07 ‰ (δ(18) O values of CO2 ), 0.11 ‰ (δ(13) C values of CH4 ) and 1.0 ‰ (δ(2) H values of CH4 ). Within a single day, the system exhibits a typical methane δ(13) C standard deviation (1σ) of 0.06 ‰ for 10 repeated measurements. The system has been in routine operation at the MPI-BGC since 2012. Consistency of the data and compatibility with results from other laboratories at a high precision level are of utmost importance. A high sample throughput and reliability of operation are important achievements of the presented system to cope with the large number of air samples to be analyzed. Copyright © 2016 John Wiley & Sons, Ltd. Copyright © 2016 John Wiley & Sons, Ltd.

  16. Do Students' Values Change in Different Types of Schools?

    ERIC Educational Resources Information Center

    Hofmann-Towfigh, Nadi

    2007-01-01

    The purpose of this study was to determine if students' values were different depending on which type of school they attended, and whether these values changed across the school year. Students of three different types of schools (private, state, religious) were measured at the beginning and the end of a school year, using the Schwartz Portrait…

  17. Establishing values-based leadership and value systems in healthcare organizations.

    PubMed

    Graber, David R; Kilpatrick, Anne Osborne

    2008-01-01

    The importance of values in organizations is often discussed in management literature. Possessing strong or inspiring values is increasingly considered to be a key quality of successful leaders. Another common theme is that organizational values contribute to the culture and ultimate success of organizations. These conceptions or expectations are clearly applicable to healthcare organizations in the United States. However, healthcare organizations have unique structures and are subject to societal expectations that must be accommodated within an organizational values system. This article describes theoretical literature on organizational values. Cultural and religious influences on Americans and how they may influence expectations from healthcare providers are discussed. Organizational cultures and the training and socialization of the numerous professional groups in healthcare also add to the considerable heterogeneity of value systems within healthcare organizations. These contribute to another challenge confronting healthcare managers--competing or conflicting values within a unit or the entire organization. Organizations often fail to reward members who uphold or enact the organization's values, which can lead to lack of motivation and commitment to the organization. Four key elements of values-based leadership are presented for healthcare managers who seek to develop as values-based leaders. 1) Recognize your personal and professional values, 2) Determine what you expect from the larger organization and what you can implement within your sphere of influence, 3) Understand and incorporate the values of internal stakeholders, and 4) Commit to values-based leadership.

  18. Carbon Dioxide Compensation Values in Citronella and Lemongrass 1

    PubMed Central

    Herath, H. M. Walter; Ormrod, Douglas P.

    1977-01-01

    Carbon dioxide compensation values of mature leaves from 10 selections of citronella (Cymbopogon nardus [L.] Rendle) grown at 32/27 or 27/21 C day/night temperatures and three strains of lemongrass (Cymbopogon citratus [D.C.] Stapf. and Cymbopogon flexuosus [D.C.] Stapf.) grown at 8- or 15-hour photoperiods were measured in a controlled environment at 25 C. All leaves had low compensation values but citronella varied from 1.3 to 9.7 μl/liter and lemongrass from 0.7 to 3.5 μl/liter. Lower growing temperature generally resulted in lower compensation values for citronella but there was no consistent photoperiod effect on lemongrass. PMID:16659935

  19. Striatal action-value neurons reconsidered.

    PubMed

    Elber-Dorozko, Lotem; Loewenstein, Yonatan

    2018-05-31

    It is generally believed that during economic decisions, striatal neurons represent the values associated with different actions. This hypothesis is based on studies, in which the activity of striatal neurons was measured while the subject was learning to prefer the more rewarding action. Here we show that these publications are subject to at least one of two critical confounds. First, we show that even weak temporal correlations in the neuronal data may result in an erroneous identification of action-value representations. Second, we show that experiments and analyses designed to dissociate action-value representation from the representation of other decision variables cannot do so. We suggest solutions to identifying action-value representation that are not subject to these confounds. Applying one solution to previously identified action-value neurons in the basal ganglia we fail to detect action-value representations. We conclude that the claim that striatal neurons encode action-values must await new experiments and analyses. © 2018, Elber-Dorozko et al.

  20. When do drilling alliances add value? The alliance value model

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Brett, J.F.; Craig, V.B.; Wadsworth, D.B.

    1996-12-31

    A recent GRI report details three previously unstudied aspects of alliances: specific measurable factors that improve alliance success, how a successful alliance should be structured, and when an alliance makes economic sense. The most innovative tool to emerge from the report, the Alliance Value Model, addresses the third aspect. The theory behind the Alliance Value Model is that the long-term viability of any drilling relationship hinges on its ability to create real value and achieve stability. Based upon the report`s findings, the most effective way to form such an alliance is through a detailed description and integration of the technicalmore » processes involved. This new type of process-driven alliance is characterized by a value chain which links together a common set of technical processes, mutually defined bottomline goals, and shared benefits. Building a process-driven alliance requires time and people and therefore has an associated cost. The real value generated by an alliance must exceed this start-up cost. The Alliance Value Model computes the net present value (NPV) of the cash flows for four different operating arrangements: (1) Business As Usual (conventional competitive bidding process), (2) Process-Driven Alliance (linking technical processes to accelerate production and reduce expenses), (3) Incentivized Process-Driven Alliance (linked technical processes with performance incentives to promote stability), and (4) No Drill Case (primarily used to gauge the market value of services). These arrangements test different degrees of process integration between an operator and its suppliers. They can also help determine if the alliance can add enough value to exceed startup costs and if the relationship will be stable. Each partner can test the impact of the relational structure on its own profitability. When an alliance is warranted, all participants can benefit from real value generated in a stable relationship.« less

  1. Measurement of δ13C values of soil amino acids by GC-C-IRMS using trimethylsilylation: a critical assessment.

    PubMed

    Rubino, Mauro; Milin, Sylvie; D'Onofrio, Antonio; Signoret, Patrick; Hatté, Christine; Balesdent, Jérôme

    2014-01-01

    In this study, we evaluated trimethylsilyl (TMS) derivatives as derivatization reagents for the compound-specific stable carbon isotope analysis of soil amino acids by gas chromatography-combustion-isotope ratio mass spectrometry (GC-C-IRMS). We used non-proteinogenic amino acids to show that the extraction-derivatization-analysis procedure provides a reliable method to measure δ(13)C values of amino acids extracted from soil. However, we found a number of drawbacks that significantly increase the final total uncertainty. These include the following: production of multiple peaks for each amino acid, identified as di-, tri- and tetra-TMS derivatives; a number of TMS-carbon (TMS-C) atoms added lower than the stoichiometric one, possibly due to incomplete combustion; different TMS-C δ(13)C for di-, tri- and tetra-TMS derivatives. For soil samples, only four amino acids (leucine, valine, threonine and serine) provide reliable δ(13)C values with a total average uncertainty of 1.3 ‰. We conclude that trimethylsilyl derivatives are only suitable for determining the (13)C incorporation in amino acids within experiments using (13)C-labelled tracers but cannot be applied for amino acids with natural carbon isotope abundance until the drawbacks described here are overcome and the measured total uncertainty significantly decreased.

  2. Challenges in Measuring Teachers' Knowledge

    ERIC Educational Resources Information Center

    Fauskanger, Janne

    2015-01-01

    Mathematical knowledge for teaching (MKT) measures have been widely adopted by researchers. Critics have debated the value of such measures and questioned the type of knowledge that these access. This article reports on a study where the challenges in measuring teachers' knowledge were illuminated through investigating relationships between the…

  3. The roles of values, behavior, and value-behavior fit in the relation of agency and communion to well-being.

    PubMed

    Buchanan, Kathryn; Bardi, Anat

    2015-06-01

    Four studies examined whether agency and communion values, behaviors, or an interaction between values and behaviors (value-behavior fit) would predict well-being. In addition, Study 2 examined whether agency and communion goals, behaviors, or goal-behavior fit would predict well-being. In all four studies, participants completed online questionnaires containing measures of agency and communion values, behaviors, and well-being. In Studies 1 and 4, participants were recruited from the general population (respectively, N = 371, Mage  = 37.49, and N = 133, Mage  = 36.59). In Studies 2 and 3, participants were undergraduate students (respectively, N = 239, Mage  = 20.8, and N = 242, Mage  = 21.6). All four studies consistently found that agency and communion behaviors were significantly positively correlated with both subjective and psychological well-being. There was no strong indication that either values were directly associated with well-being. Neither was there any indication that well-being was predicted by value-behavior fit. The implications of these findings for theory and improving well-being are discussed. © 2014 Wiley Periodicals, Inc.

  4. [Comparison of invasive blood pressure measurement in the aorta with indirect oscillometric blood pressure measurement at the wrist and forearm].

    PubMed

    Saul, F; Aristidou, Y; Klaus, D; Wiemeyer, A; Lösse, B

    1995-09-01

    Indirectly measured blood pressure at the wrist or upper arm was compared with directly measured values in the aortic arch during routinely performed diagnostic cardiac catheterization in 100 patients (31-80 years, mean 59.3 years, 60% males). The noninvasive measurements were carried out by oscillometric devices, NAiS Blood Pressure Watch for measurements at the wrist, and Hestia OZ80 at the upper arm. Systolic blood pressure measured at the wrist was 4.3 +/- 14.1 mm Hg, and the diastolic value 6.0 +/- 8.9 mm Hg higher than when measured at the aortic arch; the difference was significant in both cases. Correlation coefficients were 0.85 for systolic and 0.71 for diastolic blood pressure. In 16% of the patients the systolic blood pressure at the wrist differed more than +/- 20 mm Hg. The diastolic blood pressure at the wrist measured more than +/- 20 mm Hg higher than in the aorta in 5% of the patients. At the upper arm mean systolic values were not different to the aorta. The diastolic pressure was 9.3 +/- 9.8 mm Hg higher in the aorta than at the upper arm. To verify the accuracy of values measured with the NAiS Blood Pressure Watch compared with the standard technique at the upper arm, sequential measurements were made at wrist and ipsilateral upper arm in the same group of 100 patients. The systolic blood pressure at the left wrist was 3.4 +/- 13.3 mm Hg higher and the diastolic pressure 3.8 +/- 9.5 mm Hg lower than at the upper arm. Only 53% of systolic values lay within a range of +/- 10 mm Hg. The correspondence between wrist and upper arm values was better for diastolic blood pressure, the values differing by less than +/- 10 mm Hg in two-thirds of patients. Self-measurement of arterial blood pressure with an oscillometric device at the wrist can be recommended only in individual cases with a difference of simultaneously measured values at the upper arm of less than +/- 10 mm Hg for systolic and diastolic blood pressures. The standard method for indirectly

  5. Valuing ecosystem services from wetlands restoration in the Mississippi Alluvial Valley

    USGS Publications Warehouse

    Jenkins, W.A.; Murray, B.C.; Kramer, R.A.; Faulkner, S.P.

    2010-01-01

    This study assesses the value of restoring forested wetlands via the U.S. government's Wetlands Reserve Program (WRP) in the Mississippi Alluvial Valley by quantifying and monetizing ecosystem services. The three focal services are greenhouse gas (GHG) mitigation, nitrogen mitigation, and waterfowl recreation. Site- and region-level measurements of these ecosystem services are combined with process models to quantify their production on agricultural land, which serves as the baseline, and on restored wetlands. We adjust and transform these measures into per-hectare, valuation-ready units and monetize them with prices from emerging ecosystem markets and the environmental economics literature. By valuing three of the many ecosystem services produced, we generate lower bound estimates for the total ecosystem value of the wetlands restoration. Social welfare value is found to be between $1435 and $1486/ha/year, with GHG mitigation valued in the range of $171 to $222, nitrogen mitigation at $1248, and waterfowl recreation at $16. Limited to existing markets, the estimate for annual market value is merely $70/ha, but when fully accounting for potential markets, this estimate rises to $1035/ha. The estimated social value surpasses the public expenditure or social cost of wetlands restoration in only 1 year, indicating that the return on public investment is very attractive for the WRP. Moreover, the potential market value is substantially greater than landowner opportunity costs, showing that payments to private landowners to restore wetlands could also be profitable for individual landowners. ?? 2009 Elsevier B.V.

  6. Prognostic value of serum angiogenic activity in colorectal cancer patients

    PubMed Central

    Gonzalez, Francisco-Jesus; Quesada, Ana-Rodriguez; Sevilla, Isabel; Baca, Juan-Javier; Medina, Miguel-Angel; Amores, Jose; Diaz, Juan Miguel; Rius-Diaz, Francisca; Marques, Eduardo; Alba, Emilio

    2007-01-01

    Abstract Angiogenesis, resulting from an imbalance between angiogenic activator factors and inhibitors, is required for tumour growth and metastasis. The determination of the circulating concentration of all angiogenic factors (activators and inhibitors) is not feasible at present. We have evaluated diagnostic and prognostic values of the measurement of serum angiogenic activity in colorectal carcinoma (CRC) patients. Serum proliferative activity (PA) on human umbilical vein endothelial cells (HUVEC) in vitro, and serum vascular endothelial growth factor (VEGF) levels were determined by ELISA in 53 patients with primary CRC, 16 subjects with non-neoplastic gastrointestinal disease (SC) and 34 healthy individuals. Data were compared with clinical outcome of the patients. Although serum from CRC patients significantly increased the PA of HUVEC, compared to culture control (HUVEC in medium + 10% foetal bovine serum (FBS); P < 0.001); our results indicate that serum PA in CRC patients was similar to that of SC or healthy individuals. There was no correlation between serum PA and circulating VEGF concentrations. Surgery produced a decrease of PA at 8 hrs after tumour resection in CRC patients compared to pre-surgery values (186 ± 47 versus 213 ± 41, P < 0.001). However, an increase in serum VEGF values was observed after surgery (280 [176–450] versus 251 [160–357] pg/ml, P = 0.004). Patients with lower PA values after surgery showed a worse outcome that those with higher PA values. Therefore, this study does not support a diagnostic value for serum angiogenic activity measured by proliferative activity on HUVEC but suggests it could have a prognostic value in CRC patients. PMID:17367506

  7. Change in singing voice production, objectively measured.

    PubMed

    Schutte, Harm K; Stark, James A; Miller, Donald G

    2003-12-01

    Although subglottal pressures in conversational speech are relatively easily measured and thus known, the higher values that sometimes occur in singing (especially in tenors) have received little attention in the literature. Still more unusual is the opportunity to measure a large-scale change over decades in the application of pressure in singing production. This study compares measurements of subglottal pressure in a tenor/singing teacher (JS) at two points in his career: in his early thirties, when he was a subject in HS's dissertation study on the efficiency of voice production; and recently, in his fifties, in connection with JS's forthcoming book on the history of the pedagogy of Bel Canto. Although a single case study, its points of special interest include the high values initially measured (up to 100 cm H2O) and the reduction of this figure by more than 50% in the maximal values of the recent measurements. The study compares these values with those of other singers in the same laboratory (both with esophageal balloon and directly, with a catheter passed through the glottis) and in the literature, as well as discusses in detail the problems pertaining to the measurement (repeatability, correcting for lung volume, etc.). As a sophisticated subject, JS makes some pertinent observations about the changes in his use of subglottal pressure.

  8. Value of information and natural resources decision-making

    USGS Publications Warehouse

    Williams, Byron K.; Johnson, Fred A.

    2015-01-01

    Though the potential for information to measurably improve management has been highlighted for several decades, in recent years the “value of information” has surfaced with increasing frequency in natural resources. However, the use of this phrase belies the fact that many in natural resources have only a limited understanding about what it actually means, how to measure it, and what to do with it. We introduce and describe several forms of the value of information in a context of the management of renewable natural resources. The value of information is discussed in terms of a potential gain in value with the addition of new information, as well as a loss in value associated with the absence of information. Value metrics are developed for uncertainty about resource status as well as resource processes and responses to management. We provide a common notation for the metrics of value, and discuss linkages of the value of information to strategic approaches such as adaptive resources management and partially observable decision processes.

  9. A multinational study to measure the value that patients with cancer place on improved emesis control following cisplatin chemotherapy.

    PubMed

    Dranitsaris, G; Leung, P; Ciotti, R; Ortega, A; Spinthouri, M; Liaropoulos, L; Labianca, R; Quadri, A

    2001-01-01

    The neurokinin-1 (NK1) receptor antagonists are a new class of agents designed to reduce the risk of emesis following chemotherapy, particularly with cisplatin. Early data from double-blind randomised trials suggest that an orally administered NK1 antagonist can reduce the absolute risk of acute and delayed emesis following cisplatin by 20 and 30%, respectively. To measure the value that patients with cancer place on improved emesis control and quality of life. Willingness-to-pay analysis. Five study sites in Canada, Italy, Spain and Greece. 245 patients with cancer either receiving chemotherapy with cisplatin or who had received cisplatin-based chemotherapy within the previous 6 months. After background information had been presented, patients were asked to define the maximum that they would pay per day for a drug that reduced their risk of acute and delayed (days 2 to 5) emesis by 20 and 30%, respectively. Costs were converted to US dollars ($US) using year 2000 exchange rates. For a 20% improvement in acute emesis, Canadian, Italian and Spanish patients with cancer were willing to pay $US46, $US34 and $US63 per day, respectively, compared with $US8 for patients from Greece (p < 0.001). For a 30% improvement in delayed emesis, Canadian, Italian and Spanish patients with cancer were also willing to pay more than their Greek counterparts (SUS41, $US31, $US50 and $US9 daily for 4 days, respectively; p < 0.001). These significant differences in patient value between countries remained, even after adjusting for socioeconomic variables and previous history of emesis. There are substantial cultural differences in how patients with cancer value benefit and improved quality of life. Since the majority of the world's population resides outside North America and Western Europe, there may be a need to re-evaluate perceived levels of patient benefit and measures of quality of life.

  10. Cultural values and happiness: an East-West dialogue.

    PubMed

    Luo, L; Gilmour, R; Kao, S F

    2001-08-01

    Happiness as a state of mind may be universal, but its meaning is complex and ambiguous. The authors directly examined the relationships between cultural values and experiences of happiness in 2 samples, by using a measurement of values derived from Chinese culture and a measurement of subjective well-being balanced for sources of happiness salient in both the East and the West. The participants were university students-439 from an Eastern culture (Taiwan) and 344 from a Western culture (the United Kingdom). Although general patterns were similar in the 2 samples, the relationships between values and happiness were stronger in the Taiwanese sample than in the British sample. The values social integration and human-heartedness had culture-dependent effects on happiness, whereas the value Confucian work dynamism had a culture-general effect on happiness.

  11. The p-Value You Can't Buy.

    PubMed

    Demidenko, Eugene

    2016-01-02

    There is growing frustration with the concept of the p -value. Besides having an ambiguous interpretation, the p- value can be made as small as desired by increasing the sample size, n . The p -value is outdated and does not make sense with big data: Everything becomes statistically significant. The root of the problem with the p- value is in the mean comparison. We argue that statistical uncertainty should be measured on the individual, not the group, level. Consequently, standard deviation (SD), not standard error (SE), error bars should be used to graphically present the data on two groups. We introduce a new measure based on the discrimination of individuals/objects from two groups, and call it the D -value. The D -value can be viewed as the n -of-1 p -value because it is computed in the same way as p while letting n equal 1. We show how the D -value is related to discrimination probability and the area above the receiver operating characteristic (ROC) curve. The D -value has a clear interpretation as the proportion of patients who get worse after the treatment, and as such facilitates to weigh up the likelihood of events under different scenarios. [Received January 2015. Revised June 2015.].

  12. Improved noninvasive prediction of liver fibrosis by liver stiffness measurement in patients with nonalcoholic fatty liver disease accounting for controlled attenuation parameter values.

    PubMed

    Petta, Salvatore; Wong, Vincent Wai-Sun; Cammà, Calogero; Hiriart, Jean-Baptiste; Wong, Grace Lai-Hung; Marra, Fabio; Vergniol, Julien; Chan, Anthony Wing-Hung; Di Marco, Vito; Merrouche, Wassil; Chan, Henry Lik-Yuen; Barbara, Marco; Le-Bail, Brigitte; Arena, Umberto; Craxì, Antonio; de Ledinghen, Victor

    2017-04-01

    Liver stiffness measurement (LSM) frequently overestimates the severity of liver fibrosis in nonalcoholic fatty liver disease (NAFLD). Controlled attenuation parameter (CAP) is a new parameter provided by the same machine used for LSM and associated with both steatosis and body mass index, the two factors mostly affecting LSM performance in NAFLD. We aimed to determine whether prediction of liver fibrosis by LSM in NAFLD patients is affected by CAP values. Patients (n = 324) were assessed by clinical and histological (Kleiner score) features. LSM and CAP were performed using the M probe. CAP values were grouped by tertiles (lower 132-298, middle 299-338, higher 339-400 dB/m). Among patients with F0-F2 fibrosis, mean LSM values, expressed in kilopascals, increased according to CAP tertiles (6.8 versus 8.6 versus 9.4, P = 0.001), and along this line the area under the curve of LSM for the diagnosis of F3-F4 fibrosis was progressively reduced from lower to middle and further to higher CAP tertiles (0.915, 0.848-0.982; 0.830, 0.753-0.908; 0.806, 0.723-0.890). As a consequence, in subjects with F0-F2 fibrosis, the rates of false-positive LSM results for F3-F4 fibrosis increased according to CAP tertiles (7.2% in lower versus 16.6% in middle versus 18.1% in higher). Consistent with this, a decisional flowchart for predicting fibrosis was suggested by combining both LSM and CAP values. In patients with NAFLD, CAP values should always be taken into account in order to avoid overestimations of liver fibrosis assessed by transient elastography. (Hepatology 2017;65:1145-1155). © 2016 by the American Association for the Study of Liver Diseases.

  13. Predictive value of repeated measurements of luteal progesterone and estradiol levels in patients with intrauterine insemination and controlled ovarian stimulation.

    PubMed

    Bakas, Panagiotis; Simopoulou, Maria; Giner, Maria; Drakakis, Petros; Panagopoulos, Perikles; Vlahos, Nikolaos

    2017-10-01

    The objective of this study is to assess if the difference of repeated measurements of estradiol and progesterone during luteal phase predict the outcome of intrauterine insemination. Prospective study. Reproductive clinic. 126 patients with infertility. Patients underwent controlled ovarian stimulation with recombinant FSH (50-150 IU/d). The day of IUI patients were given p.o natural micronized progesterone in a dose of 100 mg/tds. The area under the receiver characteristic operating curve (ROC curve) in predicting clinical pregnancy for % change of estradiol level on days 6 and 10 was 0.892 with 95% CI: 0.82-0.94. A cutoff value of change > -29.5% had a sensitivity of 85.7 with a specificity of 90.2. The corresponding ROC curve for % change of progesterone level was 0.839 with 95% CI: 0.76-0.90. A cutoff value of change > -33% had a sensitivity of 85 with a specificity of 75. The % change of estradiol and progesterone between days 6 and 10 has a predictive ability of pregnancy after IUI with COS of 89.2% and 83.4%, respectively. The addition of % of progesterone to % change of estradiol does not improve the predictive ability of % estradiol and should not be used.

  14. Managing Complex IT Security Processes with Value Based Measures

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Abercrombie, Robert K; Sheldon, Frederick T; Mili, Ali

    2009-01-01

    Current trends indicate that IT security measures will need to greatly expand to counter the ever increasingly sophisticated, well-funded and/or economically motivated threat space. Traditional risk management approaches provide an effective method for guiding courses of action for assessment, and mitigation investments. However, such approaches no matter how popular demand very detailed knowledge about the IT security domain and the enterprise/cyber architectural context. Typically, the critical nature and/or high stakes require careful consideration and adaptation of a balanced approach that provides reliable and consistent methods for rating vulnerabilities. As reported in earlier works, the Cyberspace Security Econometrics System provides amore » comprehensive measure of reliability, security and safety of a system that accounts for the criticality of each requirement as a function of one or more stakeholders interests in that requirement. This paper advocates a dependability measure that acknowledges the aggregate structure of complex system specifications, and accounts for variations by stakeholder, by specification components, and by verification and validation impact.« less

  15. Economic demand and essential value.

    PubMed

    Hursh, Steven R; Silberberg, Alan

    2008-01-01

    The strength of a rat's eating reflex correlates with hunger level when strength is measured by the response frequency that precedes eating (B. F. Skinner, 1932a, 1932b). On the basis of this finding, Skinner argued response frequency could index reflex strength. Subsequent work documented difficulties with this notion because responding was affected not only by the strengthening properties of the reinforcer but also by the rate-shaping effects of the schedule. This article obviates this problem by measuring strength via methods from behavioral economics. This approach uses demand curves to map how reinforcer consumption changes with changes in the "price" different ratio schedules impose. An exponential equation is used to model these demand curves. The value of this exponential's rate constant is used to scale the strength or essential value of a reinforcer, independent of the scalar dimensions of the reinforcer. Essential value determines the consumption level to be expected at particular prices and the response level that will occur to support that consumption. This approach permits comparing reinforcers that differ in kind, contributing toward the goal of scaling reinforcer value. (c) 2008 APA, all rights reserved

  16. Variability in δ13C values between individual Daphnia ephippia: Implications for palaeo-studies

    NASA Astrophysics Data System (ADS)

    Schilder, Jos; van Roij, Linda; Reichart, Gert-Jan; Sluijs, Appy; Heiri, Oliver

    2018-06-01

    The stable carbon isotope ratio (δ13C value) of Daphnia spp. resting egg shells (ephippia) provides information on past changes in Daphnia diet. Measurements are typically performed on samples of ≥20 ephippia, which obscures the range of values associated with individual ephippia. Using a recently developed laser ablation-based technique, we perform multiple δ13C analyses on individual ephippia, which show a high degree of reproducibility (standard deviations 0.1-0.5‰). We further measured δ13C values of 13 ephippia from surface sediments of three Swiss lakes. In the well-oxygenated lake with low methane concentrations, δ13C values are close to values typical for algae (-31.4‰) and the range in values is relatively small (5.8‰). This variability is likely driven by seasonal (or inter-annual) variability in algae δ13C values. In two seasonally anoxic lakes with higher methane concentrations, average values were lower (-41.4 and -43.9‰, respectively) and the ranges much larger (10.7 and 20.0‰). We attribute this variability to seasonal variation in incorporation of methane-derived carbon. In one lake we identify two statistically distinct isotopic populations, which may reflect separate production peaks. The potentially large within-sample variability should be considered when interpreting small-amplitude, short-lived isotope excursions based on samples consisting of few ephippia. We show that measurements on single ephippia can be performed using laser ablation, which allows for refined assessments of past Daphnia diet and carbon cycling in lake food webs. Furthermore, our study provides a basis for similar measurements on other chitinous remains (e.g. from chironomids, bryozoans).

  17. Time-varying value of electric energy efficiency

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Mims, Natalie A.; Eckman, Tom; Goldman, Charles

    Electric energy efficiency resources save energy and may reduce peak demand. Historically, quantification of energy efficiency benefits has largely focused on the economic value of energy savings during the first year and lifetime of the installed measures. Due in part to the lack of publicly available research on end-use load shapes (i.e., the hourly or seasonal timing of electricity savings) and energy savings shapes, consideration of the impact of energy efficiency on peak demand reduction (i.e., capacity savings) has been more limited. End-use load research and the hourly valuation of efficiency savings are used for a variety of electricity planningmore » functions, including load forecasting, demand-side management and evaluation, capacity and demand response planning, long-term resource planning, renewable energy integration, assessing potential grid modernization investments, establishing rates and pricing, and customer service. This study reviews existing literature on the time-varying value of energy efficiency savings, provides examples in four geographically diverse locations of how consideration of the time-varying value of efficiency savings impacts the calculation of power system benefits, and identifies future research needs to enhance the consideration of the time-varying value of energy efficiency in cost-effectiveness screening analysis. Findings from this study include: -The time-varying value of individual energy efficiency measures varies across the locations studied because of the physical and operational characteristics of the individual utility system (e.g., summer or winter peaking, load factor, reserve margin) as well as the time periods during which savings from measures occur. -Across the four locations studied, some of the largest capacity benefits from energy efficiency are derived from the deferral of transmission and distribution system infrastructure upgrades. However, the deferred cost of such upgrades also exhibited the greatest

  18. The value of health care – a matter of discussion in Germany

    PubMed Central

    Porzsolt, Franz; Ackermann, Moritz; Amelung, Volker

    2007-01-01

    Background Interest in assessing the value of health-care services in Germany has considerably increased since the foundation of the Institut für Qualität und Wirtschaftlichkeit im Gesundheitswesen, IQWiG (Institute for Quality and Efficiency in Health Care). The practical application of value assessment illustrates how problematic the process can be. In all decisions made for the provision of health care, data concerning the measurable dimensions (quantity and quality of efficacy and effectiveness, validity of the results and costs) flow into a complex and not yet standardized decision-making process concerning public financing. Some of these decisions are based on data of uncertain validity, unknown reproducibility and unclear appropriateness. Discussion In this paper we describe the theoretical aspects of value from psychological and economic viewpoints and discuss national and international approaches. Methodic details and difficulties in assessing the value of health-care services are analysed. A definition of the intangible value of health-care services will be proposed which contains only three factors: the absolute risk reduction (usually a measure of efficacy), the validity of the scientific papers examined and the type of the expected effectiveness (prevention of death and disability, restitution of well-being). The intangible value describes the additional benefit when comparing two possible actions, like treatment or observation only. Conclusion The description of intangible value from the viewpoint of different stakeholders is a useful measure for subsequent steps (not discussed here) – the evaluation of costs and of patient benefit. A standardised, transparent, fair and democratic evaluation is essential for the definition of a basic benefit package. PMID:17199886

  19. 19 CFR 152.105 - Deductive value.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... its importation, and any Federal excise tax on, or measured by the value of, the merchandise for which... paragraph (c)(3) of this section, the value added by the processing of the merchandise after importation to...) of this section, deductions made for the value added by that processing will be based on objective...

  20. 19 CFR 152.105 - Deductive value.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... its importation, and any Federal excise tax on, or measured by the value of, the merchandise for which... paragraph (c)(3) of this section, the value added by the processing of the merchandise after importation to...) of this section, deductions made for the value added by that processing will be based on objective...

  1. 19 CFR 152.105 - Deductive value.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... its importation, and any Federal excise tax on, or measured by the value of, the merchandise for which... paragraph (c)(3) of this section, the value added by the processing of the merchandise after importation to...) of this section, deductions made for the value added by that processing will be based on objective...

  2. 19 CFR 152.105 - Deductive value.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... its importation, and any Federal excise tax on, or measured by the value of, the merchandise for which... paragraph (c)(3) of this section, the value added by the processing of the merchandise after importation to...) of this section, deductions made for the value added by that processing will be based on objective...

  3. 19 CFR 152.105 - Deductive value.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... its importation, and any Federal excise tax on, or measured by the value of, the merchandise for which... paragraph (c)(3) of this section, the value added by the processing of the merchandise after importation to...) of this section, deductions made for the value added by that processing will be based on objective...

  4. Measuring the Value of Earth Observation Information with the Gravity Research and Climate Experiment (GRACE) Satellite

    NASA Astrophysics Data System (ADS)

    Bernknopf, R.; Kuwayama, Y.; Brookshire, D.; Macauley, M.; Zaitchik, B.; Pesko, S.; Vail, P.

    2014-12-01

    Determining how much to invest in earth observation technology depends in part on the value of information (VOI) that can be derived from the observations. We design a framework and then evaluate the value-in-use of the NASA Gravity Research and Climate Experiment (GRACE) for regional water use and reliability in the presence of drought. As a technology that allows measurement of water storage, the GRACE Data Assimilation System (DAS) provides information that is qualitatively different from that generated by other water data sources. It provides a global, reproducible grid of changes in surface and subsurface water resources on a frequent and regular basis. Major damages from recent events such as the 2012 Midwest drought and the ongoing drought in California motivate the need to understand the VOI from remotely sensed data such as that derived from GRACE DAS. Our conceptual framework models a dynamic risk management problem in agriculture. We base the framework on information from stakeholders and subject experts. The economic case for GRACE DAS involves providing better water availability information. In the model, individuals have a "willingness to pay" (wtp) for GRACE DAS - essentially, wtp is an expression of savings in reduced agricultural input costs and for costs that are influenced by regional policy decisions. Our hypothesis is that improvements in decision making can be achieved with GRACE DAS measurements of water storage relative to data collected from groundwater monitoring wells and soil moisture monitors that would be relied on in the absence of GRACE DAS. The VOI is estimated as a comparison of outcomes. The California wine grape industry has features that allow it to be a good case study and a basis for extrapolation to other economic sectors. We model water use in this sector as a sequential decision highlighting the attributes of GRACE DAS input as information for within-season production decisions as well as for longer-term water reliability.

  5. Continuous measurement of reticuloruminal pH values in dairy cows during the transition period from barn to pasture feeding using an indwelling wireless data transmitting unit.

    PubMed

    Gasteiner, J; Horn, M; Steinwidder, A

    2015-04-01

    This study was performed to investigate the effect of the transition from barn feeding to pasture on the pattern of reticuloruminal pH values in 8 multiparous dairy cows. A indwelling wireless data transmitting system for pH measurement was given to 8 multiparous cows orally. Reticuloruminal pH values were measured every 600 s over a period of 42 days. After 7 days of barn feeding (period 1), all of the animals were pastured with increasing grazing times from 2 to 7 h/day over 7 days (period 2). From day 15 to day 21 (period 3), the cows spent 7 h/day on pasture. Beginning on day 22, the animals had 20 h/day access to pasture (day and night grazing). To study reticuloruminal adaptation to pasture feeding, the phase of day and night grazing was subdivided into another 3 weekly periods (periods 4-6). Despite a mild transition period from barn feeding to pasture, significant effects on reticuloruminal pH values were observed. During barn feeding, the mean reticuloruminal pH value for all of the cows was 6.44 ± 0.14, and the pH values decreased significantly (p < 0.001) during period 2 and 3 to 6.24 ± 0.17 and 6.21 ± 0.19 respectively. During periods 4, 5 and 6, the reticuloruminal pH values increased again (pH 6.25 ± 0.22; pH 6.31 ± 0.17; pH 6.37 ± 0.16). Our results showed that the animals had significantly lowered reticuloruminal pH during the periods of feed transition from barn to pasture feeding. Despite these significant changes, the decrease was not harmful, as indicated by data of feed intake and milk production. Journal of Animal Physiology and Animal Nutrition © 2014 Blackwell Verlag GmbH.

  6. The influence of different referencing methods on the accuracy of δ(13) C value measurement of ethanol fuel by gas chromatography/combustion/isotope ratio mass spectrometry.

    PubMed

    Neves, Laura A; Rodrigues, Janaína M; Daroda, Romeu J; Silva, Paulo R M; Ferreira, Alexandre A; Aranda, Donato A G; Eberlin, Marcos N; Fasciotti, Maíra

    2015-11-15

    Brazil is the largest producer of sugar cane bioethanol in the world. Isotope ratio mass spectrometry (IRMS) is the technique of choice to certify the origin/raw materials for ethanol production, but the lack of certified reference materials (CRMs) for accurate measurements of δ(13) C values traceable to Vienna Pee Dee Belemnite (VPDB), the international zero point for (13) C/(12) C measurements, certified and compatible with gas chromatography (GC)/IRMS instruments may compromise the accuracy of δ(13) C determinations. We evaluated the influence of methods for the calibration and normalization of raw δ(13) C values of ethanol samples. Samples were analyzed by GC/C/IRMS using two different GC columns. Different substances were used as isotopic standards for the working gas calibration. The δ(13) C values obtained with the three methods of normalization were statistically compared with those obtained with elemental analyzer (EA)/IRMS, since the δ(13) C results obtained using EA are traceable to VPDB via the NBS 22 reference material. It was observed that both the isotopic reference material for CO2 calibration and the GC column have a major effect on the δ(13) C measurements, leading to a bias of almost 2-3 ‰ in the δ(13) C values. All three methods of normalization were equivalent in performance, enabling an improvement in the GC/C/IRMS accuracy, compared with the EA/IRMS reference values for the samples. All the methods of CO2 calibration, chromatography and normalization presented in this work demonstrated several sources of traceability and accuracy loss for the determination of δ(13) C values in ethanol fuel samples by GC/C/IRMS. This work has also shown the importance of using proper CRMs traceable to VPBD that should be compatible and certified using GC/C/IRMS, ideally in a wide range of δ(13) C values. This is important not only for bioethanol fuel samples, but also for many analytes commonly analyzed by IRMS. Copyright © 2015 John Wiley & Sons

  7. A Study of Factors Influencing Environmental Values in Junior and Senior High School Students.

    ERIC Educational Resources Information Center

    Alaimo, Samuel J.; Doran, Rodney L.

    1978-01-01

    The Environmental Inventory was used to measure environmental values classified as follows: aesthetic, economic, political, social, theoretical, and religious. Findings indicate that these values can be validly measured in junior and senior high school and are affected by grade level (age) and amount of science instruction experienced, but not by…

  8. New approach for the identification of implausible values and outliers in longitudinal childhood anthropometric data.

    PubMed

    Shi, Joy; Korsiak, Jill; Roth, Daniel E

    2018-03-01

    We aimed to demonstrate the use of jackknife residuals to take advantage of the longitudinal nature of available growth data in assessing potential biologically implausible values and outliers. Artificial errors were induced in 5% of length, weight, and head circumference measurements, measured on 1211 participants from the Maternal Vitamin D for Infant Growth (MDIG) trial from birth to 24 months of age. Each child's sex- and age-standardized z-score or raw measurements were regressed as a function of age in child-specific models. Each error responsible for a biologically implausible decrease between a consecutive pair of measurements was identified based on the higher of the two absolute values of jackknife residuals in each pair. In further analyses, outliers were identified as those values beyond fixed cutoffs of the jackknife residuals (e.g., greater than +5 or less than -5 in primary analyses). Kappa, sensitivity, and specificity were calculated over 1000 simulations to assess the ability of the jackknife residual method to detect induced errors and to compare these methods with the use of conditional growth percentiles and conventional cross-sectional methods. Among the induced errors that resulted in a biologically implausible decrease in measurement between two consecutive values, the jackknife residual method identified the correct value in 84.3%-91.5% of these instances when applied to the sex- and age-standardized z-scores, with kappa values ranging from 0.685 to 0.795. Sensitivity and specificity of the jackknife method were higher than those of the conditional growth percentile method, but specificity was lower than for conventional cross-sectional methods. Using jackknife residuals provides a simple method to identify biologically implausible values and outliers in longitudinal child growth data sets in which each child contributes at least 4 serial measurements. Crown Copyright © 2018. Published by Elsevier Inc. All rights reserved.

  9. Value is in the eye of the beholder: early visual cortex codes monetary value of objects during a diverted attention task.

    PubMed

    Persichetti, Andrew S; Aguirre, Geoffrey K; Thompson-Schill, Sharon L

    2015-05-01

    A central concern in the study of learning and decision-making is the identification of neural signals associated with the values of choice alternatives. An important factor in understanding the neural correlates of value is the representation of the object itself, separate from the act of choosing. Is it the case that the representation of an object within visual areas will change if it is associated with a particular value? We used fMRI adaptation to measure the neural similarity of a set of novel objects before and after participants learned to associate monetary values with the objects. We used a range of both positive and negative values to allow us to distinguish effects of behavioral salience (i.e., large vs. small values) from effects of valence (i.e., positive vs. negative values). During the scanning session, participants made a perceptual judgment unrelated to value. Crucially, the similarity of the visual features of any pair of objects did not predict the similarity of their value, so we could distinguish adaptation effects due to each dimension of similarity. Within early visual areas, we found that value similarity modulated the neural response to the objects after training. These results show that an abstract dimension, in this case, monetary value, modulates neural response to an object in visual areas of the brain even when attention is diverted.

  10. Time-Varying Value of Energy Efficiency in Michigan

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Mims, Natalie; Eckman, Tom; Schwartz, Lisa C.

    Quantifying the time-varying value of energy efficiency is necessary to properly account for all of its benefits and costs and to identify and implement efficiency resources that contribute to a low-cost, reliable electric system. Historically, most quantification of the benefits of efficiency has focused largely on the economic value of annual energy reduction. Due to the lack of statistically representative metered end-use load shape data in Michigan (i.e., the hourly or seasonal timing of electricity savings), the ability to confidently characterize the time-varying value of energy efficiency savings in the state, especially for weather-sensitive measures such as central air conditioning,more » is limited. Still, electric utilities in Michigan can take advantage of opportunities to incorporate the time-varying value of efficiency into their planning. For example, end-use load research and hourly valuation of efficiency savings can be used for a variety of electricity planning functions, including load forecasting, demand-side management and evaluation, capacity planning, long-term resource planning, renewable energy integration, assessing potential grid modernization investments, establishing rates and pricing, and customer service (KEMA 2012). In addition, accurately calculating the time-varying value of efficiency may help energy efficiency program administrators prioritize existing offerings, set incentive or rebate levels that reflect the full value of efficiency, and design new programs.« less

  11. Morality, values, traditional bullying, and cyberbullying in adolescence.

    PubMed

    Menesini, Ersilia; Nocentini, Annalaura; Camodeca, Marina

    2013-03-01

    The aim of the present study was to investigate moral aspects and human values in traditional bullying and cyberbullying, in order to detect differences between the two types of bullying and to test the role of immoral and disengaged behaviours in mediating the relationships between personal values and involvement in bullying. Sample comprised 390 adolescents aged 14-18, balanced for gender, attending different high schools. Traditional and cyberbullying were detected by means of two self-report measures, while the Portrait Values Questionnaire was used to assess 10 values in four dimensions according to the value system model by Schwartz (1992): self-trascendence, self-enhancement, openness to change, and conservation. Finally, immoral and disengaged behaviours were assessed by means of five items about behavioural and personal aspects salient for morality. Results showed that, irrespective of gender, self-enhancement and self-trascendence moderately predicted cyber and traditional bullying, respectively, while immoral and disengaged behaviours predicted both. Indirect effects showed that self-enhancement and openness to change predicted both forms of bullying through immoral behaviour. Results are discussed in terms of similarities and differences between cyber and traditional bullying and with attention to the central role of morality in explaining bullying nature. © 2011 The British Psychological Society.

  12. Measured values of coal mine stopping resistance

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Oswald, N.; Prosser, B.; Ruckman, R.

    2008-12-15

    As coal mines become larger, the number of stoppings in the ventilation system increases. Each stopping represents a potential leakage path which must be adequately represented in the ventilation model. Stopping resistance can be calculated using two methods, the USBM method, used to determine a resistance for a single stopping, and the MVS technique, in which an average resistance is calculated for multiple stoppings. Through MVS data collected from ventilation surveys of different subsurface coal mines, average resistances for stoppings were determined for stopping in poor, average, good, and excellent conditions. The calculated average stoppings resistance were determined for concretemore » block and Kennedy stopping. Using the average stopping resistance, measured and calculated using the MVS method, provides a ventilation modeling tool which can be used to construct more accurate and useful ventilation models. 3 refs., 3 figs.« less

  13. Value-Based Care in the Worldwide Battle Against Cancer.

    PubMed

    Johansen, Niloufer J; Saunders, Christobel M

    2017-02-17

    Globally, an increasing and aging population is contributing to the prevalence of cancer. To be effective, cancer care needs to involve the coordination of multidisciplinary specialties, and also needs to be affordable, accessible, and capable of producing optimal patient outcomes. Porter and Teisberg (2006) have postulated that shifting current healthcare strategies from volume-based to patient-centric care redirects economic competition to providing treatments which promote the best patient outcomes while driving down costs. Therefore, the value in value-based healthcare (VBH) is defined as patient outcome per currency spent on providing care. Based on the experiences of healthcare organizations currently transitioning to the value-based system, this review details actionable guidelines to transition current cancer care practices to the value-based system in four main steps: by defining universal clinical and patient-reported measures, creating cancer-specific units that provide the full care cycle, establishing a data capture model to routinely determine the value of the care delivered, and continually improving treatment strategies through research. As healthcare providers in more developed countries move to value-based care, those located in less developed countries should also be assisted in their transition to relieve the cancer burden globally.

  14. Putting the value into biosimilar decision making: the judgment value criteria.

    PubMed

    Mendes de Abreu, Mirhelen; Strand, Vibeke; Levy, Roger Abramino; Araujo, Denizar Vianna

    2014-06-01

    Uncertainties remain the key issue surrounding biosimilars, although decisions regarding their use must be made. The challenges for policymakers, doctors, patients and others seeking to navigate in the uncharted waters of biosimilars must be clarified. At the most basic level, scientific understanding of the issue remains limited and when making decisions, policymakers must consider all those affected by health policy decisions, particularly the ultimate recipients of these medicines: the patients. The biosimilar-value chain relies on measurement of comparabilities. The goal is to demonstrate how, from a molecular perspective, closely similar they are or are not and how potential small differences may be relevant to clinical outcomes. To critically understand these points, this conceptual paper will present a knowledge-value chain and discuss each dimension assigning value in the decision making process re-utilization of biosimilars. Copyright © 2014 Elsevier B.V. All rights reserved.

  15. Empathy, values, morality and Asperger's syndrome.

    PubMed

    Hirvelä, Shari; Helkama, Klaus

    2011-12-01

    The aims of this study were, first, to re-address the issue of empathy among people with autism conditions; second, to explore the relationships between empathy and values among autistic populations and controls; and third, to explore the capacity for moral agency among those affected by autism. We compared responses of an Asperger group (N = 41) and a control group (N = 139) to measures of self-reported empathy (Davis's IRI) and value priorities (Schwartz's PVQ). Control group results were largely in line with previous studies, such that empathy subscales of perspective taking and empathic concern showed their strongest positive and negative relations to the Schwartz self-transcendence/self-enhancement dimensions. Results for the Asperger group showed that although on the one hand there were self-reported difficulties in perspective taking and the cognitive recognition of affect, and that on the other hand there were less connections between the empathy and value measures, there was nevertheless a comparable prioritization of moral values. Conclusions suggest that different people may acquire moral values through different mechanisms. © 2011 The Authors. Scandinavian Journal of Psychology © 2011 The Scandinavian Psychological Associations.

  16. [Value-Added--Adding Economic Value in the Food Industry].

    ERIC Educational Resources Information Center

    Welch, Mary A., Ed.

    1989-01-01

    This booklet focuses on the economic concept of "value added" to goods and services. A student activity worksheet illustrates how the steps involved in processing food are examples of the concept of value added. The booklet further links food processing to the idea of value added to the Gross National Product (GNP). Discussion questions,…

  17. Establishing Common Cost Measures to Evaluate the Economic Value of Patient Navigation Programs

    PubMed Central

    Whitley, Elizabeth; Valverde, Patricia; Wells, Kristen; Williams, Loretta; Teschner, Taylor; Shih, Ya-Chen Tina

    2011-01-01

    Background Patient navigation is an intervention aimed at reducing barriers to healthcare for underserved populations as a means to reduce cancer health disparities. Despite the proliferation of patient navigation programs across the United States, information related to the economic impact and sustainability of these programs is lacking. Method Following a review of the relevant literature, the Health Services Research (HSR) cost workgroup of the American Cancer Society National Patient Navigator Leadership Summit met to examine cost data relevant to assessing the economic impact of patient navigation and to propose common cost metrics. Results Recognizing that resources available for data collection, management and analysis vary, five categories of core and optional cost measures were identified related to patient navigator programs, including, program costs, human capital costs, direct medical costs, direct non-medical costs and indirect costs. Conclusion(s) Information demonstrating economic as well as clinical value is necessary to make decisions about sustainability of patient navigation programs. Adoption of these common cost metrics are recommended to promote understanding of the economic impact of patient navigation and comparability across diverse patient navigation programs. PMID:21780096

  18. Value-Added and Observational Measures Used in the Teacher Evaluation Process: A Validation Study

    ERIC Educational Resources Information Center

    Guerere, Claudia

    2013-01-01

    Scores from value-added models (VAMs), as used for educational accountability, represent the educational effect teachers have on their students. The use of these scores in teacher evaluations for high-stakes decision making is new for the State of Florida. Validity evidence that supports or questions the use of these scores is critically needed.…

  19. Comparison of β Values in Rocks Deduced From the Elastoacoustic Effect and From 3-Wave Mixing

    NASA Astrophysics Data System (ADS)

    Dangelo, R.; Winkler, K. W.; Johnson, D. L.

    2002-12-01

    We measure the changes in the speeds of sound in Berea, wet and dry, due to the application of non-isotropic stresses (elastoacoustic effect). From these measurements we deduce values of the 3rd order elastic constants, A,B,C. We insonify these same samples, immersed in a water tank, with well-characterized acoustic signals having frequency content f1 = 1.05 MHz and f2 = 0.95 MHz. The nonlinear properties of the samples generate a difference frequency component at Δ f = 100 kHz whose amplitude we measure (3-wave mixing). We analyze the combined effects of diffraction, attenuation, and nonlinearity on these difference frequency signals by means of the KZK equation, suitably modified to account for the actual frequency dependence of the attenuation in these samples. The attenuation of the higher frequency nonlinear signals, f1+f_2, 2f1, 2f2, precludes our ability to measure them. The values of β deduced from the 3-wave mixing measurements are in the hundreds whereas the values of β implied by the values of A,B,C are in the thousands. The same experiments on lucite yield β values consistent with each other: β ≈ 6. In lucite we are easily able to measure the higher frequency nonlinear signals. The high attenuation in rocks precludes their measurement at these frequencies.

  20. Teacher Values and Relationship: Factors in Values Education

    ERIC Educational Resources Information Center

    Brady, Laurie

    2011-01-01

    Intrigued by the notion that effective teaching is as much about relationship as it is about "technical" proficiency, the author examines the values of teachers that inform classroom relationships, and poses the question as to whether there are particular teacher values that are necessary for quality values education. This question is…

  1. Measuring the level of agreement in hematologic and biochemical values between blood sampling sites in leatherback sea turtles (Dermochelys coriacea).

    PubMed

    Stewart, Kimberly; Mitchell, Mark A; Norton, Terry; Krecek, Rosina C

    2012-12-01

    Conservation programs to protect endangered sea turtles are being instituted worldwide. A common practice in these programs is to collect blood to evaluate the health of the turtles. Several different venipuncture sites are used to collect blood from sea turtles for hematologic and biochemistry tests, depending on the species. To date, it is unknown what affect venipuncture site may have on sample results. The purpose of this study was to measure the level of agreement between hematologic and biochemistry values collected from the dorsal cervical sinus and the interdigital vein of leatherback (Dermochelys coriacea) sea turtles. Paired heparinized blood samples were obtained from the dorsal cervical sinus and the interdigital vein of 12 adult female nesting leatherback sea turtles on Keys Beach, St. Kitts, West Indies. Even though the sample population was small, the data for each chemistry were normally distributed, except for creatine kinase (CK). There was no significant difference when comparing biochemistry or hematologic values by venipuncture site, except for CK (P = 0.02). The level of agreement between sampling sites was considered good for albumin, calcium, globulin, glucose, packed cell volume, phosphorus, potassium, sodium, total protein, total solids, uric acid, white blood cell count, and all of the individual white cell types, while the level of agreement for aspartate aminotransferase and CK were considered poor. This information, coupled with the fact that the interdigital vein affords a less-invasive procedure, demonstrates that the interdigital vein is an appropriate location to use when establishing a hematologic and biochemical profile for leatherback sea turtles.

  2. Measuring Teacher Effectiveness with the Pennsylvania Value-Added Assessment System

    ERIC Educational Resources Information Center

    Bowen, Naomi

    2017-01-01

    The purpose of this research was to determine if the Pennsylvania Value-Added Assessment System Average Growth Index (PVAAS AGI) scores, derived from standardized tests and calculated for Pennsylvania schools, provide a valid and reliable assessment of teacher effectiveness, as these scores are currently used to derive 15% of the annual…

  3. To Measure or Not To Measure--That's Still in Question.

    ERIC Educational Resources Information Center

    Goldstein, Larry

    2002-01-01

    Discusses insights from the Institutional Operating Measures Forum, sponsored by the National Association of College and University Business Officers (NACUBO) and the National Postsecondary Education Cooperative. Discussions continued the debate about the value--and the feasibility--of a standard operating measure for colleges and universities.…

  4. The value of volume and growth measurements in timber sales management of the National Forests

    NASA Technical Reports Server (NTRS)

    Lietzke, K. R.

    1977-01-01

    This paper summarizes work performed in the estimation of gross social value of timber volume and growth rate information used in making regional harvest decisions in the National Forest System. A model was developed to permit parametric analysis. The problem is formulated as one of finding optimal inventory holding patterns. Public timber management differs from other inventory holding problems in that the inventory, itself, generates value over time in providing recreational, aesthetic and environmental goods. 'Nontimber' demand estimates are inferred from past Forest Service harvest and sales levels. The solution requires a description of the harvest rates which maintain the optimum inventory level. Gross benefits of the Landsat systems are estimated by comparison with Forest Service information gathering models. Gross annual benefits are estimated to be $5.9 million for the MSS system and $7.2 million for the TM system.

  5. Measurement Error and Bias in Value-Added Models. Research Report. ETS RR-17-25

    ERIC Educational Resources Information Center

    Kane, Michael T.

    2017-01-01

    By aggregating residual gain scores (the differences between each student's current score and a predicted score based on prior performance) for a school or a teacher, value-added models (VAMs) can be used to generate estimates of school or teacher effects. It is known that random errors in the prior scores will introduce bias into predictions of…

  6. Use of value functions in environmental decisions

    NASA Astrophysics Data System (ADS)

    O'Banion, Kerry

    1980-01-01

    Value functions are devices that allow discrete analyses of environmental impacts to be reconciled to a single quantitative scale of preference. The values obtained can then be “weighted” and combined into measures of the relative desirability of policy alternatives. However, for this methodology to be valid, the set of impacts used must satisfy a number of conditions; and whether or not these are met depends on how the impacts are selected and characterized. This paper generalizes instances where the conditions may be violated and how they may be resolved, and concludes with a few thoughts on how the methodology might be adapted to the routine of bureaucracy.

  7. Aerosol-Induced Radiative Flux Changes Off the United States Mid-Atlantic Coast: Comparison of Values Calculated from Sunphotometer and In Situ Data with Those Measured by Airborne Pyranometer

    NASA Technical Reports Server (NTRS)

    Russell, P. B.; Livingston, J. M.; Hignett, P.; Kinne, S.; Wong, J.; Chien, A.; Bergstrom, R.; Durkee, P.; Hobbs, P. V.

    2000-01-01

    The Tropospheric Aerosol Radiative Forcing Observational Experiment (TARFOX) measured a variety of aerosol radiative effects (including flux changes) while simultaneously measuring the chemical, physical, and optical properties of the responsible aerosol particles. Here we use TARFOX-determined aerosol and surface properties to compute shortwave radiative flux changes for a variety of aerosol situations, with midvisible optical depths ranging from 0.06 to 0.55. We calculate flux changes by several techniques with varying degrees of sophistication, in part to investigate the sensitivity of results to computational approach. We then compare computed flux changes to those determined from aircraft measurements. Calculations using several approaches yield downward and upward flux changes that agree with measurements. The agreement demonstrates closure (i.e. consistency) among the TARFOX-derived aerosol properties, modeling techniques, and radiative flux measurements. Agreement between calculated and measured downward flux changes is best when the aerosols are modeled as moderately absorbing (midvisible single-scattering albedos between about 0.89 and 0.93), in accord with independent measurements of the TARPOX aerosol. The calculated values for instantaneous daytime upwelling flux changes are in the range +14 to +48 W/sq m for midvisible optical depths between 0.2 and 0.55. These values are about 30 to 100 times the global-average direct forcing expected for the global-average sulfate aerosol optical depth of 0.04. The reasons for the larger flux changes in TARFOX include the relatively large optical depths and the focus on cloud-free, daytime conditions over the dark ocean surface. These are the conditions that produce major aerosol radiative forcing events and contribute to any global-average climate effect.

  8. Measurement uncertainty analysis techniques applied to PV performance measurements

    NASA Astrophysics Data System (ADS)

    Wells, C.

    1992-10-01

    The purpose of this presentation is to provide a brief introduction to measurement uncertainty analysis, outline how it is done, and illustrate uncertainty analysis with examples drawn from the PV field, with particular emphasis toward its use in PV performance measurements. The uncertainty information we know and state concerning a PV performance measurement or a module test result determines, to a significant extent, the value and quality of that result. What is measurement uncertainty analysis? It is an outgrowth of what has commonly been called error analysis. But uncertainty analysis, a more recent development, gives greater insight into measurement processes and tests, experiments, or calibration results. Uncertainty analysis gives us an estimate of the interval about a measured value or an experiment's final result within which we believe the true value of that quantity will lie. Why should we take the time to perform an uncertainty analysis? A rigorous measurement uncertainty analysis: Increases the credibility and value of research results; allows comparisons of results from different labs; helps improve experiment design and identifies where changes are needed to achieve stated objectives (through use of the pre-test analysis); plays a significant role in validating measurements and experimental results, and in demonstrating (through the post-test analysis) that valid data have been acquired; reduces the risk of making erroneous decisions; demonstrates quality assurance and quality control measures have been accomplished; define Valid Data as data having known and documented paths of: Origin, including theory; measurements; traceability to measurement standards; computations; uncertainty analysis of results.

  9. Analysis of historical delta values for IAEA/LANL NDA training courses

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Geist, William; Santi, Peter; Swinhoe, Martyn

    2009-01-01

    The Los Alamos National Laboratory (LANL) supports the International Atomic Energy Agency (IAEA) by providing training for IAEA inspectors in neutron and gamma-ray Nondestructive Assay (NDA) of nuclear material. Since 1980, all new IAEA inspectors attend this two week course at LANL gaining hands-on experience in the application of NDA techniques, procedures and analysis to measure plutonium and uranium nuclear material standards with well known pedigrees. As part of the course the inspectors conduct an inventory verification exercise. This exercise provides inspectors the opportunity to test their abilities in performing verification measurements using the various NDA techniques. For an inspector,more » the verification of an item is nominally based on whether the measured assay value agrees with the declared value to within three times the historical delta value. The historical delta value represents the average difference between measured and declared values from previous measurements taken on similar material with the same measurement technology. If the measurement falls outside a limit of three times the historical delta value, the declaration is not verified. This paper uses measurement data from five years of IAEA courses to calculate a historical delta for five non-destructive assay methods: Gamma-ray Enrichment, Gamma-ray Plutonium Isotopics, Passive Neutron Coincidence Counting, Active Neutron Coincidence Counting and the Neutron Coincidence Collar. These historical deltas provide information as to the precision and accuracy of these measurement techniques under realistic conditions.« less

  10. Markovian limit for a reduced operation-valued stochastic process

    NASA Astrophysics Data System (ADS)

    Barchielli, Alberto

    1987-04-01

    Operation-valued stochastic processes give a formalization of the concept of continuous (in time) measurements in quantum mechanics. In this article, a first stage M of a measuring apparatus coupled to the system S is explicitly introduced, and continuous measurement of some observables of M is considered (one can speak of an indirect continuous measurement on S). When the degrees of freedom of the measuring apparatus M are eliminated and the weak coupling limit is taken, it is shown that an operation-valued stochastic process describing a direct continuous observation of the system S is obtained.

  11. The Mexican American Cultural Values scales for Adolescents and Adults

    PubMed Central

    Knight, George P.; Gonzales, Nancy A.; Saenz, Delia S.; Bonds, Darya D.; Germán, Miguelina; Deardorff, Julianna; Roosa, Mark W.; Updegraff, Kimberly A.

    2009-01-01

    This research evaluates the properties of a measure of culturally linked values of Mexican Americans in early adolescence and adulthood. The items measure were derived from qualitative data provided by focus groups in which Mexican Americans’ (adolescents, mothers and fathers) perceptions of key values were discussed. The focus groups and a preliminary item refinement resulted in the fifty-item Mexican American Cultural Values Scales (identical for adolescents and adults) that includes nine value subscales. Analyses of data from two large previously published studies sampling Mexican American adolescents, mothers, and fathers provided evidence of the expected two correlated higher order factor structures, reliability, and construct validity of the subscales of the Mexican American Cultural Values Scales as indicators of values that are frequently associated with Mexican/Mexican American culture. The utility of this measure for use in longitudinal research, and in resolving some important theoretical questions regarding dual cultural adaptation, are discussed. PMID:20644653

  12. Turbulence stress measurements in a nonadiabatic hypersonic boundary layer

    NASA Technical Reports Server (NTRS)

    Mikulla, V.; Horstman, C. C.

    1975-01-01

    Turbulent shear stress and direct turbulent total heat-flux measurements have been made across a nonadiabatic, zero pressure gradient, hypersonic boundary layer by using specially designed hot-wire probes free of strain-gauging and wire oscillation. Heat-flux measurements were in reasonably good agreement with values obtained by integrating the energy equation using measured profiles of velocity and temperature. The shear-stress values deduced from the measurements, by assuming zero correlation of velocity and pressure fluctuations, were lower than the values obtained by integrating the momentum equation. Statistical properties of the cross-correlations are similar to corresponding incompressible measurements at approximately the same momentum-thickness Reynolds number.

  13. Reference Values for Human Posture Measurements Based on Computerized Photogrammetry: A Systematic Review.

    PubMed

    Macedo Ribeiro, Ana Freire; Bergmann, Anke; Lemos, Thiago; Pacheco, Antônio Guilherme; Mello Russo, Maitê; Santos de Oliveira, Laura Alice; de Carvalho Rodrigues, Erika

    The main objective of this study was to review the literature to identify reference values for angles and distances of body segments related to upright posture in healthy adult women with the Postural Assessment Software (PAS/SAPO). Electronic databases (BVS, PubMed, SciELO and Scopus) were assessed using the following descriptors: evaluation, posture, photogrammetry, physical therapy, postural alignment, postural assessment, and physiotherapy. Studies that performed postural evaluation in healthy adult women with PAS/SAPO and were published in English, Portuguese and Spanish, between the years 2005 and 2014 were included. Four studies met the inclusion criteria. Data from the included studies were grouped to establish the statistical descriptors (mean, variance, and standard deviation) of the body angles and distances. A total of 29 variables were assessed (10 in the anterior views, 16 in the lateral right and left views, and 3 in the posterior views), and its respective mean and standard deviation were calculated. Reference values for the anterior and posterior views showed no symmetry between the right and left sides of the body in the frontal plane. There were also small differences in the calculated reference values for the lateral view. The proposed reference values for quantitative evaluation of the upright posture in healthy adult women estimated in the present study using PAS/SAPO could guide future studies and help clinical practice. Copyright © 2017. Published by Elsevier Inc.

  14. Carotid intima-media thickness: ultrasound measurement, prognostic value and role in clinical practice.

    PubMed

    Nair, Satheesh Balakrishnan; Malik, Rayaz; Khattar, Rajdeep S

    2012-12-01

    Ultrasound measurement of carotid intima-media thickness (IMT) has become a valuable tool for detecting and monitoring progression of atherosclerosis and recently published recommendations provide guidance for proper standardisation of these measurements. Important determinants of carotid IMT include age, gender, systolic blood pressure, diabetes mellitus and serum cholesterol levels. Many studies have shown carotid IMT to correlate with the severity of coronary atherosclerosis assessed by CT coronary calcification scores, coronary angiography and intravascular ultrasound. Consistent with its correlation with cardiovascular risk factors and coronary artery disease, a meta-analysis of large observational studies has shown carotid IMT to be a strong predictor of future cardiovascular events. Moreover, in patients with established coronary artery disease a reduction in carotid IMT has been shown to translate into a reduction in future cardiovascular events. Consensus statements now also recommend carotid IMT measurements to further refine the prognostic assessment of patients traditionally considered to be at an intermediate risk of cardiovascular disease.

  15. Prognostic Value of Serum Free Light Chains Measurements in Multiple Myeloma Patients

    PubMed Central

    Bermudo Guitarte, Carmen; Menéndez Valladares, Paloma; Rojas Noboa, Johanna Carolina; Kestler, Krysta; Duro Millán, Rafael

    2016-01-01

    Background The outcome for patients with Multiple Myeloma (MM) is highly variable, therefore, the existence of robust and easy to determine prognostic markers is extremely important for an efficient management of these patients. Presently, there is a debate about the role of the serum free light chains (sFLC) in the prognosis of MM patients both at diagnosis and after treatment. The aim of this study is to evaluate in a cohort of newly diagnosed MM patients from the Southern area of Spain, the prognostic value of sFLC both at baseline and after treatment. Materials and Methods 180 patients with a median age of 69 years were followed-up for a median time of 35 (18–61) months. The sFLC ratio (sFLCR) was calculated using the monoclonal sFLC as numerator. Patients were divided in two groups according to a sFLCR cut-off based on ROC analysis. The primary endpoints were the Overall Survival (OS) and the Progression-free Survival (PFS). Additionally, thirty-six MM patients treated with novel agents (Bortezomib/Dexamethasone) that achieved Complete Response (CR) or stringent CR (sCR) before autologous stem cell transplantation were studied to assess the impact of sCR in Disease Free Survival (DFS) and OS. Results During follow-up there were 72 disease-related deaths. The 5-years OS for the whole group was 51%. However, separate analysis of patients with sFLCR above (group “high”) or below (groups “low”) the cut-off value of 47 shows an OS of 23% and 73%, respectively (HR = 5.03, 95%CI 2.99–8.50, p<0.001). In addition, analysis by ISS stage, showed that the presence of high sFLCR was always significantly associated with a worse OS. Multivariate analysis identified sFLCR (HR = 4.42, 95%CI 2.57–7.60, p<0.001) and beta-2-microglobulin (B2M) (HR = 3.04, 95%IC 1.75–5.31, p<0.001) as independent risk factors for adverse outcome. A new risk stratification model based on sFLCR≥47 and B2M>3.5 mg/L provided a statistically more significant result for this cohort

  16. Perceived cultural importance and actual self-importance of values in cultural identification.

    PubMed

    Wan, Ching; Chiu, Chi-yue; Tam, Kim-pong; Lee, Sau-lai; Lau, Ivy Yee-man; Peng, Siqing

    2007-02-01

    Cross-cultural psychologists assume that core cultural values define to a large extent what a culture is. Typically, core values are identified through an actual self-importance approach, in which core values are those that members of the culture as a group strongly endorse. In this article, the authors propose a perceived cultural importance approach to identifying core values, in which core values are values that members of the culture as a group generally believe to be important in the culture. In 5 studies, the authors examine the utility of the perceived cultural importance approach. Results consistently showed that, compared with values of high actual self-importance, values of high perceived cultural importance play a more important role in cultural identification. These findings have important implications for conceptualizing and measuring cultures. ((c) 2007 APA, all rights reserved).

  17. The value of hemodynamic measurements by air plethysmography in diagnosing venous obstruction of the lower limb.

    PubMed

    Kurstjens, Ralph L M; de Wolf, Mark A F; Alsadah, Sarah A; Arnoldussen, Carsten W K P; Strijkers, Rob H W; Toonder, Irwin M; Wittens, Cees H A

    2016-07-01

    Air plethysmography (APG) is a functional, noninvasive test that can assess volumetric changes in the lower limb and might therefore be used as a diagnostic tool in chronic deep venous disease. However, use of APG in chronic deep venous obstructive disease remains debatable. This study assessed the clinical value of APG in identifying chronic deep venous obstruction. All patients referred to our tertiary, outpatient clinic between January 2011 and August 2013 with chronic venous complaints and suspected outflow obstruction underwent an outflow fraction (OF), ejection fraction (EF), and residual volume fraction (RVF) test using APG. Duplex ultrasound and magnetic resonance venography were used to establish whether and where obstruction was present. Diagnostic values of these tests were assessed for obstructions at different levels of the deep venous system. A total of 312 limbs in 248 patients were tested. Mean age was 45.5 ± 14.0 years, and 62.5% were female. In post-thrombotic disease, specificity and positive predictive value for OF were as high as 98.4% and 95.0%, respectively; however, sensitivity was 34.8% and negative predictive value was 29.6%, with no clinically relevant positive or negative likelihood ratios. No clinically relevant differences were observed in stratifying for level of obstruction. EF and RVF were as inconclusive. Neither could these parameters be used in diagnosing nonthrombotic iliac vein compression. We found a poor correlation between OF, EF, or RVF, determined by APG, and the presence of chronic deep venous obstruction. Therefore, use of its relative parameters is unwarranted in daily clinical practice. Copyright © 2016 Society for Vascular Surgery. Published by Elsevier Inc. All rights reserved.

  18. Establishing and Valuing the Effects of Improved Visibility in Eastern United States (1984)

    EPA Pesticide Factsheets

    Report seeks to establish a visibility value function; identify particular activities likely to be influenced by visibility and to measure values to households in producing these activities; and develop estimates of visibility benefits for Eastern US.

  19. Method of absorbance correction in a spectroscopic heating value sensor

    DOEpatents

    Saveliev, Alexei; Jangale, Vilas Vyankatrao; Zelepouga, Sergeui; Pratapas, John

    2013-09-17

    A method and apparatus for absorbance correction in a spectroscopic heating value sensor in which a reference light intensity measurement is made on a non-absorbing reference fluid, a light intensity measurement is made on a sample fluid, and a measured light absorbance of the sample fluid is determined. A corrective light intensity measurement at a non-absorbing wavelength of the sample fluid is made on the sample fluid from which an absorbance correction factor is determined. The absorbance correction factor is then applied to the measured light absorbance of the sample fluid to arrive at a true or accurate absorbance for the sample fluid.

  20. Estimation of value at risk and conditional value at risk using normal mixture distributions model

    NASA Astrophysics Data System (ADS)

    Kamaruzzaman, Zetty Ain; Isa, Zaidi

    2013-04-01

    Normal mixture distributions model has been successfully applied in financial time series analysis. In this paper, we estimate the return distribution, value at risk (VaR) and conditional value at risk (CVaR) for monthly and weekly rates of returns for FTSE Bursa Malaysia Kuala Lumpur Composite Index (FBMKLCI) from July 1990 until July 2010 using the two component univariate normal mixture distributions model. First, we present the application of normal mixture distributions model in empirical finance where we fit our real data. Second, we present the application of normal mixture distributions model in risk analysis where we apply the normal mixture distributions model to evaluate the value at risk (VaR) and conditional value at risk (CVaR) with model validation for both risk measures. The empirical results provide evidence that using the two components normal mixture distributions model can fit the data well and can perform better in estimating value at risk (VaR) and conditional value at risk (CVaR) where it can capture the stylized facts of non-normality and leptokurtosis in returns distribution.